WorldWideScience

Sample records for hepatic arterial flow

  1. Functional assessment of the hepatic arterial blood flow by pharmacoradiography

    Energy Technology Data Exchange (ETDEWEB)

    Stellamor, K; Hruby, W; Peschl, L

    1981-12-01

    By means of celiacography it was possible to demonstrate that parenteral medication with parathormone creates a selective dilatation of the liver vessels in man, provided that they are dilatable. This hemodynamic hormone effect could not be traced in the other mesenteric vessels. The increase of portal hypertension resulting from cirrhosis leads to a loss of the dilating ability of liver vessels. This regressive reaction is well demonstrated on the parathormone-celiacogram. Thus a functional assessment of the hepatic blood flow is possible. The extent of the dilatability of the liver artery seems to be of great importance for the prognosis and indication of the porto-systemic shunt-operation. Moreover we could show that an increase in the liver perfusion demonstrates pathologic liver processes in a better way.

  2. Changes in Hepatic Blood Flow During Transcatheter Arterial Infusion with Heated Saline in Hepatic VX2 Tumor

    International Nuclear Information System (INIS)

    Cao Wei; Li Jing; Wu Zhiqun; Zhou Changxi; Liu Xi; Wan Yi; Duan Yunyou

    2013-01-01

    Purpose. This study evaluates the influence of transcatheter arterial infusion with heated saline on hepatic arterial and portal venous blood flows to tumor and normal hepatic tissues in a rabbit VX2 tumor model. Methods. All animal experiments were approved by the institutional animal care and use committee. Twenty rabbits with VX2 liver tumors were divided into the following two groups: (a) the treated group (n = 10), which received a 60 mL transarterial injection of 60 °C saline via the hepatic artery; (b) the control group (n = 10), which received a 60 mL injection of 37 °C saline via the hepatic artery. Using ultrasonography, the blood flows in both the portal vein and hepatic artery were measured, and the changes in the hemodynamic indices were recorded before and immediately after the injection. The changes in the tumor and normal liver tissues of the two groups were histopathologically examined by hematoxylin and eosin staining after the injection. Results. After the transcatheter arterial heated infusion, there was a decrease in the hepatic arterial blood flow to the tumor tissue, a significant decrease in the hepatic artery mean velocity (P < 0.05), and a significant increase in the resistance index (P < 0.05). On hematoxylin and eosin staining, there were no obvious signs of tissue destruction in the normal liver tissue or the tumor tissue after heated perfusion, and coagulated blood plasma was observed in the cavities of intratumoral blood vessels in the treated group. Conclusions. The changes in tumor blood flow in the rabbit VX2 tumor model were presumably caused by microthrombi in the tumor vessels, and the portal vein likely mediated the heat loss in normal liver tissue during the transarterial heated infusion.

  3. Changes in Hepatic Blood Flow During Transcatheter Arterial Infusion with Heated Saline in Hepatic VX2 Tumor

    Energy Technology Data Exchange (ETDEWEB)

    Cao Wei, E-mail: cawe-001@163.com [Tangdu Hospital, The Fourth Military Medical University, Department of Interventional Radiology (China); Li Jing, E-mail: lijing02@fmmu.edu.cn [Tangdu Hospital, The Fourth Military Medical University, Department of Burn and Plastic Surgery (China); Wu Zhiqun, E-mail: zhiqunwu@fmmu.edu.cn [Tangdu Hospital, The Fourth Military Medical University, Department of Interventional Radiology (China); Zhou Changxi, E-mail: changxizhou@163.com [Chinese PLA General Hospital, Department of Respiratory Disease (China); Liu Xi, E-mail: xiliu@fmmu.edu.cn [Tangdu Hospital, The Fourth Military Medical University, Department of Ultrasound Diagnostics (China); Wan Yi, E-mail: yiwan@163.com [The Fourth Military Medical University, Department of Health Statistics, Institute for Health Informatics (China); Duan Yunyou, E-mail: yunyouduan@fmmu.edu.cn [Tangdu Hospital, The Fourth Military Medical University, Department of Ultrasound Diagnostics (China)

    2013-06-15

    Purpose. This study evaluates the influence of transcatheter arterial infusion with heated saline on hepatic arterial and portal venous blood flows to tumor and normal hepatic tissues in a rabbit VX2 tumor model. Methods. All animal experiments were approved by the institutional animal care and use committee. Twenty rabbits with VX2 liver tumors were divided into the following two groups: (a) the treated group (n = 10), which received a 60 mL transarterial injection of 60 Degree-Sign C saline via the hepatic artery; (b) the control group (n = 10), which received a 60 mL injection of 37 Degree-Sign C saline via the hepatic artery. Using ultrasonography, the blood flows in both the portal vein and hepatic artery were measured, and the changes in the hemodynamic indices were recorded before and immediately after the injection. The changes in the tumor and normal liver tissues of the two groups were histopathologically examined by hematoxylin and eosin staining after the injection. Results. After the transcatheter arterial heated infusion, there was a decrease in the hepatic arterial blood flow to the tumor tissue, a significant decrease in the hepatic artery mean velocity (P < 0.05), and a significant increase in the resistance index (P < 0.05). On hematoxylin and eosin staining, there were no obvious signs of tissue destruction in the normal liver tissue or the tumor tissue after heated perfusion, and coagulated blood plasma was observed in the cavities of intratumoral blood vessels in the treated group. Conclusions. The changes in tumor blood flow in the rabbit VX2 tumor model were presumably caused by microthrombi in the tumor vessels, and the portal vein likely mediated the heat loss in normal liver tissue during the transarterial heated infusion.

  4. Radioembolization of hepatic tumors. Flow redistribution after the occlusion of intrahepatic arteries

    International Nuclear Information System (INIS)

    Lauenstein, T.C.; Heusner, T.A.; Antoch, G.; Hamami, M.; Bockisch, A.; Ertle, J.; Schlaak, J.F.; Gerken, G.

    2011-01-01

    Radioembolization using 90yttrium is an emerging therapy option for unresectable liver malignancies. In order to reduce the number of yttrium injections, endovascular occlusion of a segmental hepatic artery has been proposed. The aim of this study was to assess whether sufficient vascular redistribution of the occluded liver segments through intrahepatic collaterals can be observed. 27 patients with hepatocellular carcinoma (n = 16) or hepatic metastases (n = 11) were studied. Hepatic angiography was performed on average 16 days prior to radioembolization. The segment II/III artery (n = 9) or the segment IV artery (n = 18) was occluded using coils. Technectium-99m-labeled macroaggregated albumin (99mTc-MAA) was injected into the right and the remaining part of the left hepatic artery in order to identify any hepatic volume not included in the perfused area. Patients underwent a SPECT/CT on average 1 h after the 99mTc-MAA injection. Two radiologists evaluated the SPECT/CT scans regarding the presence of non-perfused hepatic segments. Furthermore, hepatic perfusion was assessed by digital subtraction angiography (DSA) on the day of radioembolization. In 16 / 27 patients (59 %) a perfusion of the occluded liver segment was visible on the SPECT/CT scan. In 8 / 11 patients without flow redistribution at the time of the SPECT/CT, perfusion of the occluded segment through hepatic collaterals was observed during angiography prior to radioembolization. Hence, flow redistribution was eventually found in 24 / 27 patients (89 %). Flow redistribution after the occlusion of intrahepatic arteries prior to radioembolization can be successfully induced in the majority of patients with anatomical variants of the hepatic arteries. (orig.)

  5. Hepatic falciform artery

    International Nuclear Information System (INIS)

    Jaques, Paul F.; Mauro, Matthew A.; Sandhu, Jeet

    1997-01-01

    The hepatic falciform artery is an occasional terminal branch of the left or middle hepatic artery, and may provide an uncommon but important collateral route when the principal visceral arteries are occluded

  6. Changes in distribution of hepatic blood flow induced by intra-arterial infusion of angiotensin II in human hepatic cancer

    International Nuclear Information System (INIS)

    Sasaki, Y.; Imaoka, S.; Hasegawa, Y.

    1985-01-01

    Changes in the distribution of the hepatic blood flow induced by intra-arterial infusion of angiotensin II (AT-II) were studied in human hepatic cancers using extremely short-lived radioisotope (RI) (krypton 81 m [/sup 81m/Kr]; half-life, 13 seconds). After the start of continuous infusion of AT-II, the radioactivity of the tumor showed about a two-fold increase, whereas that of the nontumor region decreased to about one half as much as the level before the infusion. Consequently, the mean ratio of the arterial blood flow in the tumor region to that in the nontumor region (T/N ratio) increased to 3.30 (P less than 0.001). The T/N ratio showed a peak before the peripheral blood pressure reached the maximum, and thereafter tended to decrease. Intra-arterial infusion of AT-II raised the T/N ratio more obviously than did intravenous infusion of the drug, with less rise in the peripheral blood pressure. It is believed that intra-arterial infusion chemotherapy with local use of AT-II enables better accessibility of chemotherapeutic drugs to tumors

  7. Aberrant hepatic artery

    International Nuclear Information System (INIS)

    Konstam, M.A.; Novelline, R.A.; Athanasoulis, C.A.

    1979-01-01

    In a patient undergoing selective hepatic arteriography for suspected liver trauma, a nonopacified area of the liver, initially thought to represent a hepatic hematoma, was later discovered to be due to the presence of an accessory right hepatic artery arising from the superior mesenteric artery. This case illustrates the need for a search for aberrant vasculature whenever a liver hematoma is suspected on the basis of a selective hepatic arteriogram. (orig.) [de

  8. Normal variation of hepatic artery

    International Nuclear Information System (INIS)

    Kim, Inn; Nam, Myung Hyun; Rhim, Hyun Chul; Koh, Byung Hee; Seo, Heung Suk; Kim, Soon Yong

    1987-01-01

    This study was an analyses of blood supply of the liver in 125 patients who received hepatic arteriography and abdominal aortography from Jan. 1984 to Dec. 1986 at the Department of Radiology of Hanyang University Hospital. A. Variations in extrahepatic arteries: 1. The normal extrahepatic artery pattern occurred in 106 of 125 cases (84.8%) ; Right hepatic and left hepatic arteries arising from the hepatic artery proper and hepatic artery proper arising from the common hepatic artery. 2. The most common type of variation of extrahepatic artery was replaced right hepatic artery from superior mesenteric artery: 6 of 125 cases (4.8%). B. Variations in intrahepatic arteries: 1. The normal intrahepatic artery pattern occurred in 83 of 125 cases (66.4%). Right hepatic and left hepatic arteries arising from the hepatic artery proper and middle hepatic artery arising from lower portion of the umbilical point of left hepatic artery. 2. The most common variation of intrahepatic arteries was middle hepatic artery. 3. Among the variation of middle hepatic artery; Right, middle and left hepatic arteries arising from the same location at the hepatic artery proper was the most common type; 17 of 125 cases (13.6%)

  9. Hepatic artery aneurysms (HAAs)

    International Nuclear Information System (INIS)

    Nosratini, H.

    2004-01-01

    The hepatic artery aneurysms are rare, especially in interahepatic branches, The frequency consists of 75-80% extrahepatic and 20-25% intrahepatic. Catheterization is achieved usually from common femoral artery, other methods implemented in the case of unsuccessful catheterization from femoral artery, are translumbar and brachial catheterization. The study consist of 565 patients that were referred to the angiography ward, During seven years of assessment, five cases of hepatic artery aneurysm were found; this is a rare condition reported in the English literature. In the literature as well as in this case report the hepatic artery aneurysms are rare. In reported series the extrahepatic artery aneurysms are found more often than in the intrahepatic artery aneurysm but in this case report intrahepatic artery aneurysms are more than extrahepatic one. (author)

  10. Estimation of the Arterial Fraction of Total Hepatic Flow from Radionuclide Angiogram Using 99mTc-DISIDA

    International Nuclear Information System (INIS)

    Lee, Hae Gin; Lim, Gye Yeon; Yang, Il Kwon; Kim, Hack Hee; Lim, Jung Ik; Bahk, Yong Whee; Han, Sok Won; Han, Nam Ik; Lee, Young Sok

    1991-01-01

    Arterial fraction of total hepatic blood flow was estimated by a new method, slope method, on radionuclide angiogram using 99m Tc-DISIDA and was compared with that from 99m Tc-Phytate radionuclide angiogram. This study included 11 of normal subjects, 37 of intermediate group with various liver diseases, and 25 patients with liver cirrhosis. We analyzed the data with slope method from radionuclide angiograms and the results were compared with hepatic arterial fractions from uptake method, introduced by Lee et al. at 1986. The hepatic arterial fractions from radionuclide angiograms using 99m Tc-DISIDA and 99m Tc- Phytate were 0.32 ± 0.09 and 0.31 ± 0.11 respectively in normal subjects, and 0.75 ± 0.18 and 0.77 ± 0.21 respectively in patients with liver cirrhosis. The hepatic arterial fractions by the slope method was well correlated with those of the uptake method on 99m Tc-DISIDA scan. There was high correlation between the hepatic arterial fractions from 99m Tc-DISIDA and 99m Tc-Phytate scans. Hepatic arterial fraction estimated by the slope method is a useful index for the diagnosis of liver cirrhosis and the evaluation of status of portal hypertension.

  11. Accurate perioperative flow measurement of the portal vein and hepatic and renal artery: A role for preoperative MRI?

    Energy Technology Data Exchange (ETDEWEB)

    Vermeulen, Mechteld A.R., E-mail: mar.vermeulen@vumc.nl [Department of Surgery, VU University Medical Center, P.O. Box 7057, 1007 MB Amsterdam (Netherlands); Ligthart-Melis, Gerdien C., E-mail: g.ligthart-melis@vumc.nl [Department of Internal Medicine, Dietetics and Nutritional Sciences, VU University Medical Center, P.O. Box 7057, 1007 MB Amsterdam (Netherlands); Buijsman, René, E-mail: renebuysman@gmail.com [Department of Surgery, VU University Medical Center, P.O. Box 7057, 1007 MB Amsterdam (Netherlands); Siroen, Michiel P.C., E-mail: m.siroen6@upcmail.nl [Department of Surgery, VU University Medical Center, P.O. Box 7057, 1007 MB Amsterdam (Netherlands); Poll, Marcel C.G. van de, E-mail: mcg.vandepoll@ah.unimaas.nl [Department of Surgery, Maastricht University Medical Center, P.O. Box 5800, 6202 AZ Maastricht (Netherlands); Boelens, Petra G., E-mail: p.boelens@mumc.nl [Department of Surgery, Maastricht University Medical Center, P.O. Box 5800, 6202 AZ Maastricht (Netherlands); Dejong, Cornelis H.C., E-mail: chc.dejong@mumc.nl [Department of Surgery, Maastricht University Medical Center, P.O. Box 5800, 6202 AZ Maastricht (Netherlands); Schaik, Cors van, E-mail: c.vanschaik@vumc.nl [Department of Radiology, VU University Medical Center, P.O. Box 7057, 1007 MB Amsterdam (Netherlands); Hofman, Mark B.M., E-mail: mbm.hofman@vumc.nl [Department of Physics and Medical Technology, VU University Medical Center, P.O. Box 7057, 1007 MB Amsterdam (Netherlands); Leeuwen, Paul A.M. van, E-mail: pam.vleeuwen@vumc.nl [Department of Surgery, VU University Medical Center, P.O. Box 7057, 1007 MB Amsterdam (Netherlands)

    2012-09-15

    Background: Quantification of abdominal blood flow is essential for a variety of gastrointestinal and hepatic topics such as liver transplantation or metabolic flux measurement, but those need to be performed during surgery. It is not clear whether Duplex Doppler Ultrasound during surgery or MRI before surgery is the tool to choose. Objective: To examine whether preoperative evaluation of abdominal blood flow using MRI could prove to be a useful and reliable alternative for the perioperative sonographic approach. Methods: In this study portal and renal venous flow and hepatic arterial flow were sequentially quantified by preoperative MRI, preoperative and perioperative Duplex Doppler Ultrasound (DDUS). 55 Patients scheduled for major abdominal surgery were studied and methods and settings were compared. Additionally, average patient population values were compared. Results: Mean (±SD) plasmaflow measured by perioperative DDUS, preoperative DDUS and MRI, respectively was 433 ± 200/423 ± 162/507 ± 96 ml/min (portal vein); 96 ± 70/74 ± 41/108 ± 91 ml/min (hepatic artery); 248 ± 139/201 ± 118/219 ± 69 ml/min (renal vein). No differences between the different settings of DDUS measurement were detected. Equality of mean was observed for all measurements. Bland Altman Plots showed widespread margins. Hepatic arterial flow measurements correlated with each other, but portal and renal venous flow correlations were absent. Conclusions: Surgery and method (DDUS vs. MRI) do not affect mean flow values. Individual comparison is restricted due to wide range in measurements. Since MRI proves to be more reliable with respect to inter-observer variability, we recommend using mean MRI results in experimental setups.

  12. Significance of the Hepatic Artery Anatomy and Radionuclide Flow Data for the Technique and Results of Intra-arterial Infusion Chemotherapy in Patients with Liver Neoplasms

    International Nuclear Information System (INIS)

    Vaicekavicius, E.; Satkevicius, Z.; Kiudelis, J. and others

    2002-01-01

    The aim of this study was to evaluate the impact of different variations of liver vascular anatomy and hemodynamics in achieving the maximum effect of the hepatic artery infusion chemotherapy (HAIC) in patients with primary or metastatic hepatic malignancies. The retrograde analysis of hepatic artery (HA) anatomy and of radionuclide flow data on 23 patients treated by HAIC was performed. The HA anatomy was analysed according to two classification systems: the first one proposed by Michels, which describes 10 variants, and the second one proposed by Suzuki, which describes 3 variants - single, double or multiple HA with 3 subtypes of each variant (celiac, mesenteric and mixed). Additionally, before starting HAIC, 99mTc human macroalbumin was injected through the catheter at a slow rate into the HA of 10 patients with abnormal variants of HA anatomy. Radionuclide testing was performed with the aim to evaluate the subsequent intrahepatic distribution of chemotherapy agents. The intra-arterial regimen of HAIC for all patients consisted of a 5-day infusion of 5-ftorouracil or floxuridine with addition of doxorubicin or cisplatin. Such treatment was repeated every 3-4 weeks 3-6 times for every patient. The typical anatomy of HA branching was seen in 12 (52.2%) patients. The double origin of HA (according to Suzuki's classification) was seen in 9 (39.1%). In 5 (21.7%) of them the right HA was coming out from the superior mesenteric artery. In the remaining 4 (17.4%) patients the left HA was coming out from the left gastric artery. In one patient, multiple HA were observed, and there was no possibility to perform HAIC at all. The preliminary embolization of one of HA was performed in 3 patients with double HA according to Suzuki's classification. Redistribution of hepatic flow through intrahepatic collaterals was achieved in all 3 patients and assessed by radionuclide examination. The aberrant left HA was not embolized in 4 patients, because the metastatic tumours were

  13. Right hepatic artery aneurysm.

    Science.gov (United States)

    Bernal, Astrid Del Pilar Ardila; Loures, Paulo; Calle, Juan Cristóbal Ospina; Cunha, Beatriz; Córdoba, Juan Camilo

    2016-01-01

    We report a case of an aneurysm of the right hepatic artery and its multidisciplinary management by general surgery, endoscopy and radiology services. Being a case of extremely low incidence, it is important to show its diagnostic and therapeutic approach. RESUMO Relatamos um caso de aneurisma da artéria hepática direita conduzido de forma multidisciplinar pelos Serviços de Cirurgia Geral, Endoscopia e Radiologia. Em se tratando de caso de incidência baixíssima, é importante mostrar o enfoque diagnóstico e terapêutico usado em seu manejo.

  14. Quantitative Real-Time Fluoroscopy Analysis on Measurement of the Hepatic Arterial Flow During Transcatheter Arterial Chemoembolization of Hepatocellular Carcinoma: Comparison with Quantitative Digital Subtraction Angiography Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Yi-Yang; Lee, Rheun-Chuan, E-mail: rclee@vghtpe.gov.tw; Guo, Wan-Yuo, E-mail: wyguo@vghtpe.gov.tw; Chu, Wei-Fa [Taipei Veterans General Hospital, Department of Radiology (China); Wu, Frank Chun-Hsien [Siemens Healthcare Ltd. (China); Gehrisch, Sonja [Siemens Healthcare GmbH (Germany)

    2016-11-15

    PurposeTo quantify the arterial flow change during transcatheter arterial chemoembolization (TACE) for hepatocellular carcinoma (HCC) using digital subtraction angiography, quantitative color-coding analysis (d-QCA), and real-time subtraction fluoroscopy QCA (f-QCA).Materials and MethodsThis prospective study enrolled 20 consecutive patients with HCC who had undergone TACE via a subsegmental approach between February 2014 and April 2015. The TACE endpoint was a sluggish antegrade tumor-feeding arterial flow. d-QCA and f-QCA were used for determining the relative maximal density time (rT{sub max}) of the selected arteries. The rT{sub max} of the selected arteries was analyzed in d-QCA and f-QCA before and after TACE, and its correlation in both analyses was evaluated.ResultsThe pre- and post-TACE rT{sub max} of the embolized segmental artery in d-QCA and f-QCA were 1.59 ± 0.81 and 2.97 ± 1.80 s (P < 0.001) and 1.44 ± 0.52 and 2.28 ± 1.02 s (P < 0.01), respectively. The rT{sub max} of the proximal hepatic artery did not significantly change during TACE in d-QCA and f-QCA. The Spearman correlation coefficients of the pre- and post-TACE rT{sub max} of the embolized segmental artery between d-QCA and f-QCA were 0.46 (P < 0.05) and 0.80 (P < 0.001). Radiation doses in one series of d-QCA and f-QCA were 140.7 ± 51.5 milligray (mGy) and 2.5 ± 0.7 mGy, respectively.Conclusionsf-QCA can quantify arterial flow changes with a higher temporal resolution and lower radiation dose. Flow quantification of the embolized segmental artery using f-QCA and d-QCA is highly correlated.

  15. Quantitative Real-Time Fluoroscopy Analysis on Measurement of the Hepatic Arterial Flow During Transcatheter Arterial Chemoembolization of Hepatocellular Carcinoma: Comparison with Quantitative Digital Subtraction Angiography Analysis

    International Nuclear Information System (INIS)

    Lin, Yi-Yang; Lee, Rheun-Chuan; Guo, Wan-Yuo; Chu, Wei-Fa; Wu, Frank Chun-Hsien; Gehrisch, Sonja

    2016-01-01

    PurposeTo quantify the arterial flow change during transcatheter arterial chemoembolization (TACE) for hepatocellular carcinoma (HCC) using digital subtraction angiography, quantitative color-coding analysis (d-QCA), and real-time subtraction fluoroscopy QCA (f-QCA).Materials and MethodsThis prospective study enrolled 20 consecutive patients with HCC who had undergone TACE via a subsegmental approach between February 2014 and April 2015. The TACE endpoint was a sluggish antegrade tumor-feeding arterial flow. d-QCA and f-QCA were used for determining the relative maximal density time (rT_m_a_x) of the selected arteries. The rT_m_a_x of the selected arteries was analyzed in d-QCA and f-QCA before and after TACE, and its correlation in both analyses was evaluated.ResultsThe pre- and post-TACE rT_m_a_x of the embolized segmental artery in d-QCA and f-QCA were 1.59 ± 0.81 and 2.97 ± 1.80 s (P < 0.001) and 1.44 ± 0.52 and 2.28 ± 1.02 s (P < 0.01), respectively. The rT_m_a_x of the proximal hepatic artery did not significantly change during TACE in d-QCA and f-QCA. The Spearman correlation coefficients of the pre- and post-TACE rT_m_a_x of the embolized segmental artery between d-QCA and f-QCA were 0.46 (P < 0.05) and 0.80 (P < 0.001). Radiation doses in one series of d-QCA and f-QCA were 140.7 ± 51.5 milligray (mGy) and 2.5 ± 0.7 mGy, respectively.Conclusionsf-QCA can quantify arterial flow changes with a higher temporal resolution and lower radiation dose. Flow quantification of the embolized segmental artery using f-QCA and d-QCA is highly correlated.

  16. Hepatic artery perfusion imaging

    International Nuclear Information System (INIS)

    Thrall, J.H.; Gyves, J.W.; Ziessman, H.A.; Ensminger, W.D.

    1985-01-01

    Organ and region-selective intra-arterial chemotherapy have been used for more than two decades to treat malignant neoplasms in the extremities, head and neck region, pelvis, liver, and other areas. Substantial evidence of improved response to regional chemotherapy now exists, but there are stringent requirements for successful application of the regional technique. First, the chemotherapeutic agent employed must have appropriate pharmacokinetic and pharmacodynamic properties. Second, the drug must be reliably delivered to the tumor-bearing area. This typically requires an arteriographic assessment of the vascular supply of the tumor, followed by placement of a therapeutic catheter and confirmation that the ''watershed'' perfusion distribution from the catheter truly encompasses the tumor. Optimal catheter placement also minimizes perfusion of nontarget organs. Radionuclide perfusion imaging with technetium 99m-labeled particles, either microspheres or macroaggregates of albumin, has become the method of choice for making these assessments. Catheter placement itself is considered by many to represent a type of ''therapeutic'' intervention. However, once the catheter is in the hepatic artery the radionuclide perfusion technique can be used to assess adjunctive pharmacologic maneuvers designed to further exploit the regional approach to chemotherapy. This chapter presents the technetium Tc 99m macroaggregated albumin method for assessing catheter placement and the pharmacokinetic rationale for regional chemotherapy, and discusses two promising avenues for further intervention

  17. Embolization of Hepatic Arterial Branches to Simplify Hepatic Blood Flow Before Yttrium 90 Radioembolization: A Useful Technique in the Presence of Challenging Anatomy

    International Nuclear Information System (INIS)

    Karunanithy, Narayan; Gordon, Fabiana; Hodolic, Marina; Al-Nahhas, Adil; Wasan, Harpreet S.; Habib, Nagy; Tait, Nicholas P.

    2011-01-01

    Purpose: In the presence of variant hepatic arterial anatomy, obtaining whole-liver coverage with yttrium 90 (Y90) radioembolization may be challenging. The purpose of this study was to determine whether a technique whereby variant hepatic arterial branches are embolized and then Y90 is administered selectively into one remaining hepatic arterial branch results in whole-liver coverage and effective therapy. A retrospective comparison of treatment response was made between a group of patients who underwent this technique before Y90 administration and a group of patients who received standard Y90 administration as a single dose into the proper hepatic artery or in divided doses into the immediate hepatic artery branches. The rest of the workup and treatment were identical in both groups, including routine embolization of potential nonhepatic, nontarget vessels (e.g., the gastroduodenal artery). Methods: A total of 32 patients (mean age 56.9 years, range 39–77 years) treated with Y90 between June 2004 and March 2008 were analyzed. The primary malignancy was colorectal in 29, breast in 2, and cholangiocarcinoma in 1. Group 1 comprised 20 patients who had no alterations to their hepatic arterial supply. Group 2 comprised 12 cases who had undergone prior embolization of hepatic arterial branches before administration of Y90. The response to treatment was assessed by comparing standardized uptake value (SUV) on the pre- and postprocedure fludeoxyglucose positron emission tomographic studies of representative lesions within the right and left lobes of the liver. Results: In group 1, significant response (P < 0.001) was seen among right lobe lesions but not among left lobe lesions (P = 0.549). In group 2, there was a significant response among both right (P = 0.028) and left (P = 0.014) lobe lesions. No difference was found in the response of right lobe lesions (P = 0.726) between groups 1 and 2; a significantly greater response was found in group 2 compared to group 1 (P

  18. Assessment of liver circulation by quantitative scintiangiography: Evaluation of the relative contribution of the hepatic arterial and portal venous blood flows to liver perfusion

    International Nuclear Information System (INIS)

    Molino, G.; Squadrone, E.; Baccegal, M.; Magnani, C.

    1989-01-01

    Quantitative hepatic scintiangiography was previously used for evaluating the relative contribution of hepatic arterial and portal venous blood flows to the hepatic circulation. The present study compares 3 different procedures (automatic and manual integration, and slope fitting methods) for analyzing the hepatic time activity curves obtained after bolus i.v. injection of 370 MBq 99m Tc-diethylentriaminopentacetic acid. Twenty five subjects were studied: Five controls, ten cirrhotics, and ten portal hypertensive patients previously submitted to side to side portacaval anastomosis. The correspondence between results given by the different methods was satisfactory only in shunted patients, and the reproducibility of computed parameters was quite poor for all procedures. Accordingly, none of the methods can be considered as supporting reliable quantitative pathophysiological evaluations. However, the hepatic arterial/portal venous flow ratio was found to be increased in liver cirrhosis and in shunted patients and therefore, in spite of the limitations underlined before and of the absence of data on the reproducibility of consecutive injections, hepatic scintiangiography may be of some clinical utility. (orig.)

  19. Effect of obstructive jaundice on hepatic hemodynamics: use of Sonazoid-enhanced ultrasonography in a prospective study of the blood flow balance between the hepatic portal vein and hepatic artery.

    Science.gov (United States)

    Wakui, Noritaka; Takeda, Yuki; Nishinakagawa, Shuta; Ueki, Nobuo; Otsuka, Takafumi; Oba, Nobuyuki; Hashimoto, Hiroshi; Kamiyama, Naohisa; Sumino, Yasukiyo; Kojima, Tatsuya

    2015-10-01

    To prospectively clarify the effects of obstructive jaundice (OJ) on hepatic hemodynamics using contrast-enhanced ultrasonography (US). Subjects comprised 14 patients admitted to our hospital for OJ between April 2013 and March 2014. Contrast-enhanced US was performed using the LOGIQ E9 ultrasound device during the jaundice phase, before biliary drainage, and again after improvement of jaundice. After injecting the Sonazoid contrast agent, contrast dynamics were recorded in the right kidney and liver segments 5 or 6. Prototype software was used to calculate mean arrival time (AT) of the contrast agent in the liver parenchyma. Statistical analysis was performed to compare the mean AT in the jaundice and improved jaundice phases. We were unable to follow up three of the 14 patients after biliary drainage; thus, we included 11 patients for further analysis. The mean AT of the contrast agent was 2.0 ± 1.8 and 6.1 ± 2.3 s in the jaundice and improved jaundice phases, respectively, showing significantly shorter AT in the jaundice phase (p = 0.0033). Our findings indicate that OJ may influence the blood flow balance between the hepatic portal vein and hepatic artery.

  20. Hepatic artery infusion (HAI) for hepatic metastases in combination with hepatic resection and hepatic radiation

    International Nuclear Information System (INIS)

    Merrick, H.W.; Dobelbower, R.R.; Ringleint, J.F.; Skeel, R.T.

    1986-01-01

    Renewed interest in hepatic artery infusion has been stimulated by the development of a totally implantable pump which eliminates many of the problems encountered by the external pumps and catheters. As the potential benefit of hepatic artery infusion would be greater if either all gross disease were removed by prior resection, or alternatively, if non-resectable disease were irradiated in conjunction with hepatic artery infusion, the authors initiated a phase I-II trial to evaluate combined modality therapy

  1. Increase in hepatic arterial blood flow after transjugular intrahepatic portosystemic shunt creation and its potential predictive value of postprocedural encephalopathy and mortality.

    Science.gov (United States)

    Patel, N H; Sasadeusz, K J; Seshadri, R; Chalasani, N; Shah, H; Johnson, M S; Namyslowski, J; Moresco, K P; Trerotola, S O

    2001-11-01

    To determine (i) whether there is a significant increase in hepatic artery blood flow (HABF) after transjugular intrahepatic portosystemic shunt (TIPS) creation and (ii) whether the extent of incremental increase in HABF is predictive of clinical outcome after TIPS creation. Prospective, nonrandomized, nonblinded duplex Doppler ultrasound (US) examinations were performed on 24 consecutive patients (19 men; Child Class A/B/C: 4/12/8, respectively) with a mean age of 52.8 years who were referred for TIPS creation for variceal bleeding. Peak hepatic artery velocity and vessel dimensions were used to calculate the hepatic arterial blood flow (HABF) before and after TIPS creation. Patients were clinically followed in the gastrohepatology clinic and TIPS US surveillance was performed at 1 and 3 months to assess shunt function. The extent of incremental increase in HABF was analyzed as a predictor of post-TIPS encephalopathy and/or death. The technical success rate of TIPS creation was 100%. The shunt diameters were either 10 mm (n = 11) or 12 mm (n = 13). TIPS resulted in a significant reduction in the portosystemic gradient from 24.3 mm Hg +/- 5.7 to 9.3 mm Hg +/- 2.9 (P creation, from 60.8 cm/sec +/- 26.7 to 121 cm/sec +/- 51.5 (P creation, new or worsened encephalopathy developed in five patients at 30 days and in an additional three at 90 days. They were all successfully managed medically. Three patients (12.5%) died within 30 days of the TIPS procedure. The extent of incremental increase in HABF after TIPS was variable and did not correlate with the development of 30-day and 90-day encephalopathy (P =.41 and P =.83, respectively) or 30-day mortality (P =.2). HABF increases significantly after TIPS but is not predictive of clinical outcome. The significance of the incremental increase is yet to be determined.

  2. Peripheral hepatic arterial embolization with cross-linked collagen fibers

    International Nuclear Information System (INIS)

    Daniels, J.R.; Kerlan, R.K. Jr.; Dodds, L.; McLaughlin, P.; La Berge, J.M.; Harrington, D.; Daniels, A.M.; Ring, E.J.

    1986-01-01

    Hepatic artery embolization with a nonimmunogenic, cross-linked collagen preparation (Angiostat, collagen for embolization, Target Therapeutics) was studied in mongrel dogs. Flow-directed technique was used to achieve complete distal arterial occlusion. Serial liver function evaluation demonstrated marked alterations at 48 to 72 hours, partial correction at 1 week, and resolution of abnormalities by 1 month. Restoration of large-vessel blood flow was angiographically demonstrable at 1 week. Recanalization, achieved by migration of endothelial cells around the collagen, resulted in complete restoration of normal hepatic vascular and tissue anatomy at 1 month. Repeated embolization at biweekly intervals was well tolerated

  3. Primary hepatic artery embolization in pediatric blunt hepatic trauma.

    Science.gov (United States)

    Ong, Caroline C P; Toh, Luke; Lo, Richard H G; Yap, Te-Lu; Narasimhan, Kannan

    2012-12-01

    Non-operative management of isolated blunt hepatic trauma is recommended except when hemodynamic instability requires immediate laparotomy. Hepatic artery angioembolization is increasingly used for hepatic injuries with ongoing bleeding as demonstrated by contrast extravasation on the CT scan. It is used primarily or after laparotomy to control ongoing hemorrhage. Hepatic angioembolization as part of multimodality management of hepatic trauma is reported mainly in adults, with few pediatric case reports. We describe our institution experience with primary pediatric hepatic angioembolization and review the literature with regard to indications and complications. Two cases (3 and 8 years old), with high-grade blunt hepatic injuries with contrast extravasation on the CT scan were successfully managed by emergency primary hepatic angioembolization with minimal morbidity and avoided laparotomy. To date, the only reports of pediatric hepatic angioembolization for trauma are 5 cases for acute bleeding and 15 delayed cases for pseudoaneurysm. The role of hepatic angioembolization in the presence of an arterial blush on CT in adults is accepted, but contested in a pediatric series, despite higher transfusion rate and mortality rate. We propose that hepatic angioembolization should be considered adjunct treatment, in lieu of, or in addition to emergency laparotomy for hemostasis in pediatric blunt hepatic injury. Copyright © 2012 Elsevier Inc. All rights reserved.

  4. Interventional treatment of emergent hepatic artery thrombosis after liver transplantation

    International Nuclear Information System (INIS)

    Liu Fengyong; Wang Maoqiang; Wang Zhijun; Wang Zhongpu; Shi Xianjie; Zhou Ningxin

    2006-01-01

    Objective: To evaluate the safety and efficacy of the endovascular interventional techniques for the management of emergent hepatic artery thrombosis (HAT) after orthotopic liver transplantation (OLT). Methods: Ten patients (8 men and 2 women with mean age of 47 years) diagnosed with HAT after OLT were treated with interventional procedures. All patients presented with elevation of liver enzymes and bilirubin levels. The diagnosis of the HAT was suggested by doppler ultrasonography and confirmed by angiography at 16 hours to 10 days (mean, 4.5 days) after OLT. Interventional techniques consisted of indwelling transcatheter hepatic arterial thrombolysis with a low dose of urokinase monitored under ultrasonography every 6-12 hours and stent placement in the stenotic segment of the hepatic artery was undertaken. Systemic intravenous low dose of heparin was given contemporaneously. Results: Complete occlusion of the proper HA was achieved in 10 patients. Hepatic arterial flow was re-established in 8 of the 10 patients (80%) at 12 hours to 9 days (mean, 4.8 days) after the intra-arterial thrombolysis, with significant improvement of liver function. Hepatic artery stenosis at the anastomosis was found in the 8 patients, and a stent placement in the stenotic segment was performed successfully in 7 patients with degree of stenosis over 90%.Intra-arterial thrombolysis was failed in 2 cases. Intraperitoneal hemorrhage from the anastomosis occurred in 1 patient at 12 hours after the treatment, and was emergently taken for the graft revision with reanastomosis. One patient with complete occlusion of the hepatic artery at 7 days after the treatment, but having collateral flow of the liver for maintaining liver function and thus sparing further intervention. 8 patients with successful hepatic arterial recanalization carried along a good clinical course with normal graft function at a median 12 months (range, 4 to 20 months), and patent hepatic arterial flow was identified by

  5. Giant anurysin of the common hepatic artery

    International Nuclear Information System (INIS)

    Montenegro Gaite, T.; Gonzalez Garcia, A.; Cortes Gonzalez, A.; Mayol Deya, A.; Fernandez de Bobadilla, M.

    1994-01-01

    Hepatic artery aneurysms are relatively infrequent and asymptomatic processes, but are very important since their rupture can prove fatal. We present a case of partially thrombosed giant aneurysm of the common hepatic artery in a 55-year-old man. The patient presented relatively nonspecific clinical signs (pain in right abdomen was the major symptom), and was diagnosed by ultrasound computerized tomography (CT) and digital subtraction angiography. (Author) 12 refs

  6. Inferior phrenic artery embolization in the treatment of hepatic neoplasms

    International Nuclear Information System (INIS)

    Duprat, G.; Charnsangavej, C.; Wallace, S.; Carrasco, C.H.

    1988-01-01

    Twenty-nine inferior phrenic artery embolizations were performed in 20 patients with primary or metastatic hepatic neoplasms. All patients had interruption of their hepatic arteries by previous infusion of chemotherapy, hepatic arterial embolization or surgical ligation. In one patient, bilateral pleural effusions developed following embolization of the inferior phrenic artery. No other severe complications occurred. Inferior phrenic artery embolization is a safe procedure and permits the continuation of transcatheter treatment of hepatic neoplasms. (orig.)

  7. Inferior phrenic artery embolization in the treatment of hepatic neoplasms

    Energy Technology Data Exchange (ETDEWEB)

    Duprat, G.; Charnsangavej, C.; Wallace, S.; Carrasco, C.H.

    Twenty-nine inferior phrenic artery embolizations were performed in 20 patients with primary or metastatic hepatic neoplasms. All patients had interruption of their hepatic arteries by previous infusion of chemotherapy, hepatic arterial embolization or surgical ligation. In one patient, bilateral pleural effusions developed following embolization of the inferior phrenic artery. No other severe complications occurred. Inferior phrenic artery embolization is a safe procedure and permits the continuation of transcatheter treatment of hepatic neoplasms.

  8. Variation of hepatic artery on arteriogram and its clinical significance in interventional therapy for hepatic cancer

    International Nuclear Information System (INIS)

    Wang Xiaodong; Yang Renjie

    2009-01-01

    Objective: To investigate the variations of hepatic artery and its extrahepatic arteries on hepatic arteriogram and to provide benefit for transhepatic arterical chemoemblization. Methods: The hepatic arteriograms of 200 cases with unresectable hepatic malignant tumor before interventional therapy were analysed. Two interventional radiologists in common reviewed the incidences of various types according to Michels' classification, the absence of proper hepatic artery, and the variations of extrahepatic arteries originating from hepatic artery. Results: The most common hepatic artery variation was Michels type III(n=17,8.5%), followed by type II(n=10,5.0%) and V(n=9,4.5%). Proper hepatic absence was found in 25 cases and appeared as 5 subtypes. 5 kinds of extrahepatic arteries were found. The most common extrahepatic artery was the right gastric artery (n=156,78.0%), followed by cystic artery (n=126,63.0%), accessory left gastric artery (n=19,9.5%), the hepatic falciform artery (n=5,2.5%), and accessory left inferior phrenic artery (n=4,2.0%). Conclusion: There are some other variations of hepatic artery beside Michels' classification,and there are many variations of extrahepatic arteries originating from hepatic artery, it is important to assure interventional therapy effect for hepatic cancer and prevent complication. (authors)

  9. Hepatic artery aneurysm repair: a case report

    Directory of Open Access Journals (Sweden)

    Jaunoo SS

    2009-01-01

    Full Text Available Abstract Introduction Hepatic artery aneurysms remain a clinically significant entity. Their incidence continues to rise slowly and mortality from spontaneous rupture is high. Repair is recommended in those aneurysms greater than 2 cm in diameter. It is not surprising that vascular comorbidities, such as ischaemic heart disease, are common in surgical patients, particularly those with arterial aneurysms such as these. The decision of when to operate on patients who require urgent surgery despite having recently suffered an acute coronary syndrome remains somewhat of a grey and controversial area. We discuss the role of delayed surgery and postoperative followup of this vascular problem. Case presentation A 58-year-old man was admitted with a 5.5 cm hepatic artery aneurysm. The aneurysm was asymptomatic and was an incidental finding as a result of an abdominal computed tomography scan to investigate an episode of haemoptysis (Figure 1. Three weeks prior to admission, the patient had suffered a large inferior myocardial infarction and was treated by thrombolysis and primary coronary angioplasty. Angiographic assessment revealed a large aneurysm of the common hepatic artery involving the origins of the hepatic, gastroduodenal, left and right gastric arteries and the splenic artery (Figures 2 and 3. Endovascular treatment was not considered feasible and immediate surgery was too high-risk in the early post-infarction period. Therefore, surgery was delayed for 3 months when aneurysm repair with reconstruction of the hepatic artery was successfully performed. Graft patency was confirmed with the aid of an abdominal arterial duplex. Plasma levels of conventional liver function enzymes and of alpha-glutathione-S-transferase were within normal limits. This was used to assess the extent of any hepatocellular damage perioperatively. The patient made a good recovery and was well at his routine outpatient check-ups. Conclusion There is no significant

  10. Cerebral blood flow measured by arterial-spin labeling MRI: A useful biomarker for characterization of minimal hepatic encephalopathy in patients with cirrhosis

    International Nuclear Information System (INIS)

    Zheng, Gang; Zhang, Long Jiang; Zhong, Jianhui; Wang, Ze; Qi, Rongfeng; Shi, Donghong; Lu, Guang Ming

    2013-01-01

    Purpose: To investigate the role of arterial-spin labeling (ASL) MRI to non-invasively characterize the patterns of cerebral blood flow (CBF) changes in cirrhotic patients and to assess the potential of ASL MRI to characterize minimal hepatic encephalopathy (MHE). Materials and methods: This study was approved by the local ethics committee, and written informed consent was obtained from all participants. Thirty six cirrhosis patients without overt hepatic encephalopathy (16 MHE patients and 20 non hepatic encephalopathy (non-HE) patients) and 25 controls underwent ASL MRI, and CBF was measured for each subject. One-way ANOCOVA test with age and gender as covariences was used to compare CBF difference among three groups, and post hoc analysis was performed between each two groups. Region-based correlation analysis was applied between Child–Pugh score, venous blood ammonia level, neuropsychological tests and CBF values in cirrhosis patients. Receiver operator characteristic (ROC) analysis was used for assessing CBF measurements in ASL MRI to differentiate MHE from non-HE patients. Results: The gray matter CBF of MHE patients (71.09 ± 11.88 mL min −1 100 g −1 ) was significantly higher than that of non-HE patients (55.28 ± 12.30 mL min −1 100 g −1 , P < 0.01) and controls (52.09 ± 9.27 mL min −1 100 g −1 , P < 0.001). Voxel-wise ANOCOVA results showed that CBFs were significantly different among three groups in multiple gray matter areas (P < 0.05, Bonferroni corrected). Post hoc comparisons showed that CBF of these brain regions was increased in MHE patients compared with controls and non-HE patients (P < 0.05, Bonferroni corrected). CBF of the right putamen was of the highest sensitivity (93.8%) and moderate specificity (75.0%) for characterization of MHE when using the cutoff value of 50.57 mL min −1 100 g −1 . CBFs in the bilateral median cingulate gyri, left supramarginal gyrus, right angular gyrus, right heschl gyrus and right superior

  11. Cerebral blood flow measured by arterial-spin labeling MRI: A useful biomarker for characterization of minimal hepatic encephalopathy in patients with cirrhosis

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, Gang [Department of Medical Imaging, Jinling Hospital, Clinical School of Medical College, Nanjing University, Nanjing, Jiangsu, 210002 (China); College of Civil Aviation, Nanjing University of Aeronautics and Astronautics, Nanjing, Jiangsu, 210016 (China); Zhang, Long Jiang, E-mail: kevinzhlj@163.com [Department of Medical Imaging, Jinling Hospital, Clinical School of Medical College, Nanjing University, Nanjing, Jiangsu, 210002 (China); Zhong, Jianhui [Department of Imaging Sciences, University of Rochester School of Medicine and Dentistry, Box648, 601 Elmwood Avenue, Rochester, NY 14642-8648 (United States); Wang, Ze [Department of Psychiatry, Perelman School of Medicine, University of Pennsylvania, 3900 Chestnut St., Philadelphia, PA 19104 (United States); Qi, Rongfeng; Shi, Donghong [Department of Medical Imaging, Jinling Hospital, Clinical School of Medical College, Nanjing University, Nanjing, Jiangsu, 210002 (China); Lu, Guang Ming, E-mail: cjr.luguangming@vip.163.com [Department of Medical Imaging, Jinling Hospital, Clinical School of Medical College, Nanjing University, Nanjing, Jiangsu, 210002 (China)

    2013-11-01

    Purpose: To investigate the role of arterial-spin labeling (ASL) MRI to non-invasively characterize the patterns of cerebral blood flow (CBF) changes in cirrhotic patients and to assess the potential of ASL MRI to characterize minimal hepatic encephalopathy (MHE). Materials and methods: This study was approved by the local ethics committee, and written informed consent was obtained from all participants. Thirty six cirrhosis patients without overt hepatic encephalopathy (16 MHE patients and 20 non hepatic encephalopathy (non-HE) patients) and 25 controls underwent ASL MRI, and CBF was measured for each subject. One-way ANOCOVA test with age and gender as covariences was used to compare CBF difference among three groups, and post hoc analysis was performed between each two groups. Region-based correlation analysis was applied between Child–Pugh score, venous blood ammonia level, neuropsychological tests and CBF values in cirrhosis patients. Receiver operator characteristic (ROC) analysis was used for assessing CBF measurements in ASL MRI to differentiate MHE from non-HE patients. Results: The gray matter CBF of MHE patients (71.09 ± 11.88 mL min{sup −1} 100 g{sup −1}) was significantly higher than that of non-HE patients (55.28 ± 12.30 mL min{sup −1} 100 g{sup −1}, P < 0.01) and controls (52.09 ± 9.27 mL min{sup −1} 100 g{sup −1}, P < 0.001). Voxel-wise ANOCOVA results showed that CBFs were significantly different among three groups in multiple gray matter areas (P < 0.05, Bonferroni corrected). Post hoc comparisons showed that CBF of these brain regions was increased in MHE patients compared with controls and non-HE patients (P < 0.05, Bonferroni corrected). CBF of the right putamen was of the highest sensitivity (93.8%) and moderate specificity (75.0%) for characterization of MHE when using the cutoff value of 50.57 mL min{sup −1} 100 g{sup −1}. CBFs in the bilateral median cingulate gyri, left supramarginal gyrus, right angular gyrus, right

  12. Right Hepatic Artery: A Cadaver Investigation and Its Clinical Significance

    Directory of Open Access Journals (Sweden)

    Usha Dandekar

    2015-01-01

    Full Text Available The right hepatic artery is an end artery and contributes sole arterial supply to right lobe of the liver. Misinterpretation of normal anatomy and anatomical variations of the right hepatic artery contribute to the major intraoperative mishaps and complications in hepatobiliary surgery. The frequency of inadvertent or iatrogenic hepatobiliary vascular injury rises with the event of an aberrant anatomy. This descriptive study was carried out to document the normal anatomy and different variations of right hepatic artery to contribute to existing knowledge of right hepatic artery to improve surgical safety. This study conducted on 60 cadavers revealed aberrant replaced right hepatic artery in 18.3% and aberrant accessory right hepatic artery in 3.4%. Considering the course, the right hepatic artery ran outside Calot’s triangle in 5% of cases and caterpillar hump right hepatic artery was seen in 13.3% of cases. The right hepatic artery (normal and aberrant crossed anteriorly to the common hepatic duct in 8.3% and posteriorly to it in 71.6%. It has posterior relations with the common bile duct in 16.7% while in 3.4% it did not cross the common hepatic duct or common bile duct. The knowledge of such anomalies is important since their awareness will decrease morbidity and help to keep away from a number of surgical complications.

  13. Radiologic management of hepatic arterial stenosis or thrombosis following liver transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Byung Suck; Sung, Kyu Bo; Lim, Soo Mee; Yoon, Hyun Ki; Song, Ho Young [Asan Medical Center, Ulsan Univ. College of Medicine, Seoul (Korea, Republic of)

    2001-06-01

    To assess the results and usefulness of interventional procedures for hepatic arterial stenosis or thrombosis following liver transplantation. During the past five years, eight patients aged 1-59 (mean, 39) years among 187 liver transplant recipients showed elevated of liver enzyme levels (AST/ALT) and decreased arterial flow at Doppler ultrasound. Hepatic arteriography revealed luminal stenosis or occlusion at the proper hepatic artery, and six patients, one of whom required thrombolysis before the procedure, underwent percutaneous transluminal angioplasty (PTA) using a balloon. In two with thrombosis, thrombolysis without PTA was performed. In order to increase hepatic arterial flow, four patients underwent additional coil embolization of the gastroduodenal or splenic artery. Hepatic arterial flow recovered in all six patients after PTA. Three required repeat PTA for restenosis and one of these needed stent placement after repeated PTA. At follow-up, 6-17 months later, the three had good hepatic function. Within four days, the other three expired due to graft failure, hepatorenal syndrome and sepsis. One of the patients who underwent thrombolysis without PTA expired and the other required retransplantation. In this case there were no procedure - related complications. Radiologic interventions are useful for treatment of hepatic arterial stensis or thrombosis in patients with liver transplantations.

  14. Changes in cerebral blood flow after transjugular intrahepatic portosystemic shunt can help predict the development of hepatic encephalopathy: An arterial spin labeling MR study

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, Gang [Department of Medical Imaging, Jinling Hospital, Clinical School of Medical College, Nanjing University, Nanjing, Jiangsu 210002 (China); College of Civil Aviation, Nanjing University of Aeronautics and Astronautics, Nanjing, Jiangsu 210016 (China); Zhang, Long Jiang [Department of Medical Imaging, Jinling Hospital, Clinical School of Medical College, Nanjing University, Nanjing, Jiangsu 210002 (China); Wang, Ze [Department of Psychiatry, Perelman School of Medicine, University of Pennsylvania, 3900 Chestnut St., Philadelphia, PA 19104 (United States); Qi, Rong Feng; Shi, Donghong [Department of Medical Imaging, Jinling Hospital, Clinical School of Medical College, Nanjing University, Nanjing, Jiangsu 210002 (China); Wang, Li [Department of Medical Imaging, Jinling Hospital, Clinical School of Medical College, Nanjing University, Nanjing, Jiangsu 210002 (China); College of Civil Aviation, Nanjing University of Aeronautics and Astronautics, Nanjing, Jiangsu 210016 (China); Fan, Xinxin [Research Institute of General Surgery, Jinling Hospital, Clinical School of Medical College, Nanjing University, Nanjing, Jiangsu 210002 (China); Lu, Guang Ming, E-mail: kevinzhanglongjiang@yahoo.com.cn [Department of Medical Imaging, Jinling Hospital, Clinical School of Medical College, Nanjing University, Nanjing, Jiangsu 210002 (China)

    2012-12-15

    Background and purpose: Cerebral blood flow (CBF) changes after transjugular intrahepatic portosystemic shunt (TIPS) are still unclear. Our aim is to assess the TIPS-induced CBF changes and their potential clinical significance using the arterial spin labeling (ASL) perfusion magnetic resonance imaging. Materials and methods: Nine cirrhotic patients underwent ASL 1–8 days before and 4–7 days after TIPS. CBF was calculated at each voxel and mean CBF values were computed in the whole brain, gray matter and white matter. Changes of CBFs before and after TIPS were compared by paired t-test. Results: Voxel-wise results showed CBF diffusely increased in patients after TIPS, but no region with significant decrease in CBF was found, nor was any significant mean CBF difference detected in the whole brain, gray matter and white matter. Six patients out of nine showed a global CBF increase of 9–39%; one patient presented a global CBF decrease of 6%; another two showed a global CBF decrease of 16% and 31% respectively. Follow-up studies showed that the two patients with greatly decreased global CBF suffered from multiple episodes of overt hepatic encephalopathy (OHE) after TIPS and one died of OHE. Conclusions: CBF derived from noninvasive ASL MRI could be used as a useful biomarker to predict the development of OHE through consecutively tracking CBF changes in patients with inserted TIPS. Increased CBFs in many cortical regions could be common effects of the TIPS procedure, while decreased global CBF following TIPS might indicate the development of OHE.

  15. Abnormal splenic artery diameter/hepatic artery diameter ratio in cirrhosis-induced portal hypertension

    Science.gov (United States)

    Zeng, Dao-Bing; Dai, Chuan-Zhou; Lu, Shi-Chun; He, Ning; Wang, Wei; Li, Hong-Jun

    2013-01-01

    AIM: To determine an optimal cutoff value for abnormal splenic artery diameter/proper hepatic artery diameter (S/P) ratio in cirrhosis-induced portal hypertension. METHODS: Patients with cirrhosis and portal hypertension (n = 770) and healthy volunteers (n = 31) underwent volumetric computed tomography three-dimensional vascular reconstruction to measure the internal diameters of the splenic artery and proper hepatic artery to calculate the S/P ratio. The cutoff value for abnormal S/P ratio was determined using receiver operating characteristic curve analysis, and the prevalence of abnormal S/P ratio and associations between abnormal S/P ratio and major complications of portal hypertension were studied using logistic regression. RESULTS: The receiver operating characteristic analysis showed that the cutoff points for abnormal splenic artery internal diameter and S/P ratio were > 5.19 mm and > 1.40, respectively. The sensitivity, specificity, positive predictive value, and negative predictive value were 74.2%, 45.2%, 97.1%, and 6.6%, respectively. The prevalence of an abnormal S/P ratio in the patients with cirrhosis and portal hypertension was 83.4%. Patients with a higher S/P ratio had a lower risk of developing ascites [odds ratio (OR) = 0.708, 95%CI: 0.508-0.986, P = 0.041] and a higher risk of developing esophageal and gastric varices (OR = 1.483, 95%CI: 1.010-2.175, P = 0.044) and forming collateral circulation (OR = 1.518, 95%CI: 1.033-2.230, P = 0.034). After splenectomy, the portal venous pressure and maximum and mean portal venous flow velocities were reduced, while the flow rate and maximum and minimum flow velocities of the hepatic artery were increased (P portal hypertension, and it can be used as an important marker of splanchnic hemodynamic disturbances. PMID:23483462

  16. Hepatitis C virus infection and risk of coronary artery disease

    DEFF Research Database (Denmark)

    Roed, Torsten; Lebech, Anne-Mette; Kjaer, Andreas

    2012-01-01

    Several chronic infections have been associated with cardiovascular diseases, including Chlamydia pneumoniae, human immunodeficiency virus and viral hepatitis. This review evaluates the literature on the association between chronic hepatitis C virus (HCV) infection and the risk of coronary artery...

  17. Hepatic telangiectasia in Osler's disease treated with arterial embolization

    Energy Technology Data Exchange (ETDEWEB)

    Goethlin, J H; Nordgard, K; Jonsson, K; Nyman, U

    1982-02-01

    Hepatic hereditary telangiectasia in 2 females was treated with hepatic artery embolization. In one patient both peripheral and central arterial occlusion was performed; the patient died of massive gastro-intestinal bleeding 2 months later. Autopsy showed extensive regions with necrosis in the right liver lobe. In the next patient only central occlusion of the right hepatic artery was performed and the arterio-venous shunting in the left liver lobe left remaining. After a long reconvalescence period the patient recovered completely. It is advocated to centrally occlude only that hepatic artery supplying the most affected parts of the liver in Osler's disease. Thus extensive necrosis with possible ensuing death may be avoided.

  18. DSA analysis of the normal and variant hepatic arterial anatomy

    International Nuclear Information System (INIS)

    Lv Penghua; Wang Jie; Shi Haibing; Feng Yaoliang; Chen Huizhu; Chen Yuqin

    2005-01-01

    Objective: To observe and analyze the normal and variant hepatic arterial anatomy by DSA. Methods: One thousand and two hundreds patients with routine celiac and/or selective hepatic arteriography from November 1994 to March 2003 were retrospectively analyzed, some of them were further simultaneously undergone superior mesenteric arteriography, left gastric arteriography or inferior phrenic arteriography etc. Results: 873 (72.8%) patients had the standard hepatic arterial anatomy. 156(13.0%) patients had variant left hepatic arteries (LHAs), 120(10.0%) with variant right hepatic arteries (RHAs) and 21 (1.8%) of a variant anatomy involving both LHA and RHA. The common hepatic artery (CHA) of 1170 (97.5%) patients originated from the celiac artery. 92.0% proper hepatic artery (PHA) was the direct extension of CHA. The RHA was mainly (89.8%) derived from the PHA. There was some variation of the middle hepatic artery (MHA) with more than 62.2% arising from the LHA. The LHA was derived from the PHA (44.6%) or the RHA(30.2%) or other arteries (25.2%). Conclusions: The knowledge of normal and variant anatomy of hepatic vasculature by DSA may be very helpful for intervention therapy and hepatosurgery. (authors)

  19. Pulsatile versus steady infusions for hepatic artery chemotherapy

    International Nuclear Information System (INIS)

    Kim, E.E.; Haynie, T.P.; Wright, K.C.; Chaynsangavej, C.; Gianturco, C.; Lamki, L.; Wallace, S.

    1984-01-01

    Hepatic artery chemotherapy for unresectable liver tumors requires an even distribution of the drugs in the tumor or vascular bed. This cannot be determined angiographically because the drugs are infused at a much lower rate than the contrast media. It is easy, however, to determine the quality of the perfusion by injecting a small volume of Tc-99m MAA in one of the side ports while chemotherapeutic agent is being infused at the same rate. Usually this shows a uniform, satisfactory distribution of isotope. Occasionally, however, some areas fail to receive Tc-99m in spite of what appears to be a good position of the catheter tip. Since ''streaming'' of the infused drugs has been blamed for their uneven distribution, the authors decided to compare the usual steady flow infusions with infusions made pulsatile by the addition of a pulsing device (Gianturco Pump) attached to the infusion tubing. Eighty-three patients were studied with steady as well as pulsatile infusions. In 16 of these patients the perfusion pattern was definitely changed by the pulsatile infusion. In one patient the pulsatile mode resulted in an unwanted gastric perfusion. In 5 patients the distribution was improved in one hepatic lobe and in 10 patients it was improved in both lobes. These results show that hepatic artery perfusions can occasionally be improved by pulsing the infusate. However, pulsing can produce the unwanted perfusion of extra-hepatic areas

  20. Effects of hepatic arterial yttrium 90 glass microspheres in dogs.

    Science.gov (United States)

    Wollner, I; Knutsen, C; Smith, P; Prieskorn, D; Chrisp, C; Andrews, J; Juni, J; Warber, S; Klevering, J; Crudup, J

    1988-04-01

    A 22-micron glass microsphere called TheraSphere (Theragenics Corp., Atlanta, GA) has been developed in which yttrium 89 oxide is incorporated into the glass matrix and is activated by neutron bombardment to form the beta-emitting isotope yttrium 90 (Y 90) before using the spheres as radiotherapeutic vehicles. The injection of up to 12 times (on a liver weight basis) the anticipated human dose of nonradioactive TheraSphere into the hepatic arteries of dogs was well tolerated and produced clinically silent alterations within centrolobular areas. The hepatic arterial (HA) injection of radioactive TheraSphere also produced portal changes similar to those observed in humans after external beam therapy. While the extent of damage increased with the delivered dose, radiation exposures in excess of 30,000 cGy did not cause total hepatic necrosis and were compatible with survival. No microspheres distributed to the bone marrow and absolutely no myelosuppression was encountered in any animal. Proposed hepatic exposures to humans of 5000 to 10,000 cGy by means of these microspheres, therefore, would appear to be feasible and tolerable. Radiotherapeutic microsphere administration preceded by regional infusion of a radiosensitizing agent and/or immediately following the redistribution of blood flow toward intrahepatic tumor by vasoactive agents can potentially yield a synergistic, highly selective attack on tumors confined to the liver.

  1. The fatal risk in hepatic artery embolization for hemostasis after pancreatic and hepatic surgery: importance of collateral arterial pathways.

    Science.gov (United States)

    Sato, Akihiro; Yamada, Takayuki; Takase, Kei; Matsuhashi, Toshio; Higano, Shuichi; Kaneda, Tomohiro; Egawa, Shinichi; Takeda, Kazunori; Ishibashi, Tadashi; Takahashi, Shoki

    2011-03-01

    To assess retrospectively the cause of hepatic failure related to hepatic arterial embolization (HAE) for hemostasis after pancreaticoduodenectomy or hepatic lobectomy. Between June 1993 and March 2006, Twenty HAEs in 17 patients (15 men, two women; mean age, 64 years) were performed. Angiographic findings, including portal vein stenosis, collateral arterial pathways after HAE, and the difference of embolic materials, were recorded. The morbidity (hepatic failure and abscess) and mortality were detailed according to collateral arterial pathways, portal vein stenosis, and embolic material used. Bleeding was controlled in all patients, although two patients required repeat embolization. Hepatic failure (n = 8) and abscess (n = 2) arose in nine of 20 HAEs. Death occurred after six of eight HAEs complicated by hepatic failure. The morbidity and mortality rates of HAE were 45% and 30%, respectively. Hepatic complication was eight times more likely to occur (P = .005) in cases with no hepatic collaterals involving hepatic, replaced, or accessory hepatic arteries. Death was observed only in the cases without hepatic collaterals (P = .011). The correlation between the embolization outcome and the presence of portal vein stenosis or the difference of embolic materials was not significant (P > .61). HAE can be used to successfully control bleeding secondary to hepatic arterial rupture. In the absence of hepatic collaterals, collateral circulation distal to the occlusion from nonhepatic sources may be inadequate and lead to hepatic failure after HAE. Copyright © 2011 SIR. Published by Elsevier Inc. All rights reserved.

  2. Hepatic arterial pseudoaneurysm: a rare complication of blunt abdominal trauma in children

    International Nuclear Information System (INIS)

    Basile, K.E.; Sivit, C.J.; Sachs, P.B.; Stallion, A.

    1999-01-01

    We report a child who developed a hepatic artery pseudoaneurysm following blunt hepatic injury. This is a rare complication of hepatic trauma in children. The imaging evaluation and clinical management of hepatic artery pseudoaneurysms are presented. (orig.)

  3. Nursing implications for Hepatic arterial perfusion scintigraphy

    International Nuclear Information System (INIS)

    Ellender, R.

    1999-01-01

    Nurses working in Nuclear Medicine assist in Hepatic Artery Catheter (HAC) perfusion studies. This scan is not widely performed in Australia, the St George hospital for example performs approximately five per year. The purpose of this article is firstly to review the indications and rationale of HAC patency studies. Secondly, this article will stress the clinical implications for the Nuclear Medicine Nurse during this study. Emphasis will be placed on the importance of patient education during the procedure. A brief overview of hepatic anatomy and the radiopharmaceuticals administered during the scan is discussed. Finally, a step by step protocol is presented to show how the perfusion/ shunt study is performed. Copyright (1999) The Australian and New Zealand Society of Nuclear Medicine Inc

  4. Development of extrahepatic arterial blood supply to the liver during hepatic arterial infusion chemotherapy

    International Nuclear Information System (INIS)

    Seki, H.; Kimura, M.; Yoshimura, N.; Yamamoto, S.; Ozaki, T.; Sakai, K.

    1998-01-01

    The aim of this study was to evaluate the correlation of development of the collateral circulation to the liver during hepatic arterial infusion chemotherapy (HAIC) with the presence of hepatic tumours adjacent to the hepatic surface, and with pretreatment occlusion of aberrant hepatic arteries. In 102 patients with unresectable malignant hepatic tumours treated with HAIC using an implantable port system, development of collaterals to the liver was assessed with CT arteriography using the implantable port and pre- and postoperative angiography. Aberrant hepatic arteries, if present, were occluded prior to treatment for hepatic arterial redistribution. Collaterals to the liver were seen in 29 patients, who had 35 areas with collateral perfusion: 22 areas were in the right posterosuperior area, 6 in the left peripheral area and 7 in the right or left lobar area. Collaterals were revealed more frequently in patients with hepatic tumours adjacent to the hepatic surface than in those without hepatic tumours in peripheral areas in the liver (p < 0.0001). In addition, collaterals developed more frequently in patients with an aberrant hepatic arterial anatomy compared with those with conventional anatomy (p = 0.0007). Our results indicated that patients with hepatic tumours adjacent to the hepatic surface and with pretreatment occlusion of aberrant hepatic arteries had the potential to develop collaterals to the liver during HAIC. (orig.)

  5. Liver microcirculation after hepatic artery embolization with degradable starch microspheres in vivo

    Institute of Scientific and Technical Information of China (English)

    Jian Wang; Satoru Murata; Tatsuo Kumazaki

    2006-01-01

    AIM: To observe the dynamic changes of liver microcirculation in vivo after arterial embolization with degradable starch microspheres (DSM).METHODS: DSM were injected into the proper hepatic artery through a silastic tube inserted retrogradely in gastroduodenal artery (GDA) of SD rats. Fluorescent microscopy was used to evaluate the dynamic changes of blood flow through the terminal portal venules (TPVs), sinusoids and terminal hepatic venules (THVs).The movements of DSM debris were also recorded. Six hours after injection of DSM, percentages of THVs with completely stagnant blood flow were recorded.RESULTS: Two phases of blood flow change were recorded. In phase one: after intra-arterial injection of DSM, slow or stagnant blood flow was immediately recorded in TPVs, sinusoids and THVs. This change was reversible, and blood flow resumed completely. In phase two: after phase one, blood flow in TPVs changed again and three patterns of blood flow were recorded. Six hours after DSM injection, 36.9% ± 9.2% of THVs were found with completely stagnant blood flow.CONCLUSION: DSM can stop the microcirculatory blood flow in some areas of liver parenchyma. Liver parenchyma supplied by arteries with larger A-P shunt is considered at a higher risk of total microcirculatory blood stagnation after injection of DSM through hepatic artery.

  6. Miscellaneous Endovascular Treatment of Ruptured Hepatic Artery Pseudoaneurysms after Pylorus Preserving Pancreaticoduodenectomy

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Ung Rae; Lee, Young Hwan [Dept. of Radiology, Daegu Catholic University Medical Center, Catholic of Daegu University School of Medicine, Daegu (Korea, Republic of); Ahn, Eun Joung; Kim, See Hyung; Kim, Young Hwan [Dept. of Radiology, Keimyung University Dongsan Medical Center, Keimyung University College of Medicine, Daegu (Korea, Republic of)

    2012-03-15

    To assess the feasibility and safety of the endovascular treatment of ruptured hepatic artery pseudoaneurysms after pylorus preserving pancreaticoduodenectomy (PPPD). Thirteen patients with hepatic artery pseudoaneurysm after PPPD were enrolled. Various endovascular techniques were used depending on the sites and morphologies of the pseudoaneurysms. Five cases were treated by coil embolization, five with stent-graft, one by thrombin injection and coil embolization, one with stent-graft and coil embolization, and one with N-butyl cyanoacrylate (NBCA) injection. Computed tomography scans and liver function test were performed after the procedures. Pseudoaneurysm exclusion and bleeding cessation was achieved in all patients. In four patients that underwent coil or NBCA embolization of the hepatic artery, aspartate transaminase (AST) and alanine transaminase (ALT) were markedly elevated. Two of these four patients with narrowing of the portal vein due to surrounding hematoma died of hepatic infarction or hepatic abscess. In other nine patients, AST and ALT were unchanged. In the 11 surviving patients, normal hepatic function and complete pseudoaneurysm disappearance were achieved during follow-up. Endovascular treatment of ruptured hepatic artery pseudoaneurysms can be considered as a feasible and safe method. However, complete occlusion of the hepatic artery with coils should be avoided in patients with inadequate portal flow.

  7. Quantitative assessment of hepatic and splenic blood flow detected by Tc-99m-Sn colloid liver scintigraphy

    International Nuclear Information System (INIS)

    Narabayashi, Isamu; Nishiyama, Shoji; Sugimura, Kazuro

    1983-01-01

    Quantitative assessment of hepatic and splenic blood flow detected by injecting Tc-99m-Sn colloid as a bolus was performed on 75 patients who were suspected of having liver disease. Using a computer, the hepatic and splenic time-activity curves were analyzed. Hepatic index was calculated as the ratio of arterial to portal blood flow. The peak time of the right kidney was corresponded to the junction of the arterial and portal phases of the hepatic curve. Splenic index was calculated as the ratio of splenic arterial to liver arterial blood flow. Hepatic and splenic indices had elevated in cases of liver cirrhosis and hepatoma than those of normal controls. There was no significant difference in the hepatic and splenic indices among chronic hepatitis, liver metastasis and normal subject. These noninvasive tests for the hepatic and splenic blood flow may be useful in writing a report of liver scintigram because of the added information of the liver. (author)

  8. Resolution of Hepatic Encephalopathy Following Hepatic Artery Embolization in a Patient with Well-Differentiated Neuroendocrine Tumor Metastatic to the Liver

    International Nuclear Information System (INIS)

    Erinjeri, Joseph P.; Deodhar, Ajita; Thornton, Raymond H.; Allen, Peter J.; Getrajdman, George I.; Brown, Karen T.; Sofocleous, Constantinos T.; Reidy, Diane L.

    2010-01-01

    Hepatic encephalopathy is considered a contraindication to hepatic artery embolization. We describe a patient with a well-differentiated neuroendocrine tumor metastatic to the liver with refractory hepatic encephalopathy and normal liver function tests. The encephalopathy was refractory to standard medical therapy with lactulose. The patient's mental status returned to baseline after three hepatic artery embolization procedures. Arteriography and ultrasound imaging before and after embolization suggest that the encephalopathy was due to arterioportal shunting causing hepatofugal portal venous flow and portosystemic shunting. In patients with a primary or metastatic well-differentiated neuroendocrine tumor whose refractory hepatic encephalopathy is due to portosystemic shunting (rather than global hepatic dysfunction secondary to tumor burden), hepatic artery embolization can be performed safely and effectively.

  9. Interventional treatment of upper gastrointestinal bleeding in patients of hepatic carcinoma accompanied with hepatic artery-portal vein shunting

    International Nuclear Information System (INIS)

    Li Jijun; Shang Jianqiang; Liu Zuoqin; Tang Jun; Sun Zengtao; Chen Jie; Zhang Lei; Liu Hongjun; Zhou Zhaohai

    2011-01-01

    Objective: To explore the diagnostic and therapeutic efficacy of interventional procedure for upper gastrointestinal bleeding in patients of hepatic carcinoma accompanied with hepatic artery-portal vein shunting (HAPVS). Methods: Clinical data of 27 patients of hepatic carcinoma accompanied with HAPVS were retrospectively analyzed. All patients underwent hepatic arterial angiography and transcatheter arterial embolization. Shunts were embolized with coils, Gelfoam particles or PVA particles. Results: Of 27 patients with upper gastrointestinal bleeding, central type HAPVS was seen in 16 and peripheral type HAPVS in 11. Reversed portal venous flow was detected in 20 cases and ascites was found in 23 cases. The abnormal shunts were successfully occluded in all patients and the bleeding ceased within 2 days after embolization. No recurrent bleeding occurred in one month after the treatment. Ascites disappeared in 16 cases and subsided in 7 cases. Conclusion: HAPVS is an important cause for upper gastrointestinal bleeding in patients of hepatic carcinoma, and the arteriovenous fistula can be confirmed with hepatic artery DSA. Embolization of fistulous orifice is the most effective therapy for such patients. (authors)

  10. Extrahepatic Arteries Originating from Hepatic Arteries: Analysis Using CT During Hepatic Arteriography and Visualization on Digital Subtraction Angiography

    International Nuclear Information System (INIS)

    Ozaki, Kumi; Kobayashi, Satoshi; Matsui, Osamu; Minami, Tetsuya; Koda, Wataru; Gabata, Toshifumi

    2017-01-01

    PurposeTo investigate the prevalence and site of origin of extrahepatic arteries originating from hepatic arteries on early phase CT during hepatic arteriography (CTHA) was accessed. Visualization of these elements on digital subtraction hepatic angiography (DSHA) was assessed using CTHA images as a gold standard.Materials and MethodsA total of 943 patients (mean age 66.9 ± 10.3 years; male/female, 619/324) underwent CTHA and DSHA. The prevalence and site of origin of extrahepatic arteries were accessed using CTHA and visualized using DSHA.ResultsIn 924 (98.0%) patients, a total of 1555 extrahepatic branches, representing eight types, were found to originate from hepatic arteries on CTHA. CTHA indicated the following extrahepatic branch prevalence rates: right gastric artery, 890 (94.4%); falciform artery, 386 (40.9%); accessory left gastric artery, 161 (17.1%); left inferior phrenic artery (IPA), 43 (4.6%); posterior superior pancreaticoduodenal artery, 33 (3.5%); dorsal pancreatic artery, 26 (2.8%); duodenal artery, 12 (1.3%); and right IPA, 4 (0.4%). In addition, 383 patients (40.6%) had at least one undetectable branch on DSHA. The sensitivity, specificity, and accuracy of visualization on DSHA were as follows: RGA, 80.0, 86.8, and 80.4%; falciform artery, 53.9, 97.7, and 80.0%; accessory LGA, 64.6, 98.6, and 92.3%; left IPA, 76.7, 99.8, and 98.7%; PSPDA, 100, 99.7, and 99.9%; dorsal pancreatic artery, 57.7, 100, and 98.8%; duodenal artery, 8.3, 99.9, and 98.7%; and right IPA, 0, 100, and 99.6%, respectively.ConclusionExtrahepatic arteries originating from hepatic arteries were frequently identified on CTHA images. These arteries were frequently overlooked on DSHA.

  11. Extrahepatic Arteries Originating from Hepatic Arteries: Analysis Using CT During Hepatic Arteriography and Visualization on Digital Subtraction Angiography

    Energy Technology Data Exchange (ETDEWEB)

    Ozaki, Kumi, E-mail: ozakik-rad@umin.org [Kanazawa University Graduate School of Medical Science, Department of Radiology (Japan); Kobayashi, Satoshi [Kanazawa University Graduate School of Medical Science, Department of Quantum Medicine Technology (Japan); Matsui, Osamu; Minami, Tetsuya; Koda, Wataru; Gabata, Toshifumi [Kanazawa University Graduate School of Medical Science, Department of Radiology (Japan)

    2017-06-15

    PurposeTo investigate the prevalence and site of origin of extrahepatic arteries originating from hepatic arteries on early phase CT during hepatic arteriography (CTHA) was accessed. Visualization of these elements on digital subtraction hepatic angiography (DSHA) was assessed using CTHA images as a gold standard.Materials and MethodsA total of 943 patients (mean age 66.9 ± 10.3 years; male/female, 619/324) underwent CTHA and DSHA. The prevalence and site of origin of extrahepatic arteries were accessed using CTHA and visualized using DSHA.ResultsIn 924 (98.0%) patients, a total of 1555 extrahepatic branches, representing eight types, were found to originate from hepatic arteries on CTHA. CTHA indicated the following extrahepatic branch prevalence rates: right gastric artery, 890 (94.4%); falciform artery, 386 (40.9%); accessory left gastric artery, 161 (17.1%); left inferior phrenic artery (IPA), 43 (4.6%); posterior superior pancreaticoduodenal artery, 33 (3.5%); dorsal pancreatic artery, 26 (2.8%); duodenal artery, 12 (1.3%); and right IPA, 4 (0.4%). In addition, 383 patients (40.6%) had at least one undetectable branch on DSHA. The sensitivity, specificity, and accuracy of visualization on DSHA were as follows: RGA, 80.0, 86.8, and 80.4%; falciform artery, 53.9, 97.7, and 80.0%; accessory LGA, 64.6, 98.6, and 92.3%; left IPA, 76.7, 99.8, and 98.7%; PSPDA, 100, 99.7, and 99.9%; dorsal pancreatic artery, 57.7, 100, and 98.8%; duodenal artery, 8.3, 99.9, and 98.7%; and right IPA, 0, 100, and 99.6%, respectively.ConclusionExtrahepatic arteries originating from hepatic arteries were frequently identified on CTHA images. These arteries were frequently overlooked on DSHA.

  12. Post partum occlusion of the hepatic artery

    International Nuclear Information System (INIS)

    Buecheler, E.; Hagemann, J.; Remmecke, J.; Hamburg Univ.

    1980-01-01

    A case of post partum acute thrombosis of the hepatic artery with infarction of the liver is reported. The prognosis depends on the areas of obstruction, on the early development of a collateral circulation and on the contribution to the blood supply from the portal vein. The diagnosis of liver infarction was made by computed tomography. This was characterised by sharply demarkated hypodense areas, which did not enhance with contrast. An important clue is the lack of increase in density in the liver after intravenous injection of contrast when compared with the increased contrast of the spleen. This finding provided the indication for angiography. This confirmed the diagnosis of acute occlusion and made appropriate treatment possible. (orig.) [de

  13. Endovascular Treatment of Pseudoaneurysm of the Common Hepatic Artery with Intra-aneurysmal Glue (N-Butyl 2-Cyanoacrylate) Embolization

    International Nuclear Information System (INIS)

    Garg, Ashwin; Banait, Swati; Babhad, Sudeep; Kanchankar, Niraj; Nimade, Pradeep; Panchal, Chintan

    2007-01-01

    A 40-year-old man, a chronic alcoholic, presented with acute epigastric pain. Selective celiac arteriography showed a pseudoaneurysm arising from the common hepatic artery. We hereby describe a technical innovation where complete pseudoaneurysm exclusion was seen after intra-aneurysmal N-butyl 2-cyanoacrylate (glue) injection with preservation of antegrade hepatic arterial flow and conclude that intra-aneurysmal liquid injection may have potential as a therapeutic option to reconstruct a defective vessel wall and thereby maintain the antegrade flow

  14. Common hepatic artery aneurysm: Pseudopseudocyst of the pancreas

    International Nuclear Information System (INIS)

    Shultz, S.; Druy, E.M.; Friedman, A.C.

    1985-01-01

    The preoperative diagnosis of hepatic artery aneurysm is uncommon, and its presentation as a pancreatic mass is rare. Because of its great potential for rupture early diagnosis and treatment is essential. The authors report two cases of aneurysms of the common hepatic artery, which on CT presented as a cystic mass in the head of the pancreas. These cases illustrate the importance of using 10-mm serial sections through the pancreas after a bolus injection of intravenous contrast material in order to allow distinction between hepatic artery aneurysm and other, more common, cystic masses of the pancreas

  15. Analysis of branching patterns of middle hepatic artery using A-P and oblique view hepatic angiography

    International Nuclear Information System (INIS)

    Han, Kun Soo; Chang, Jae Chun; Park, Bok Hwan

    1992-01-01

    A study on branching patterns of middle hepatic artery was performed in 109 patients with A-P and oblique view hepatic angiogram, which refereed to size and location of quadrate lobe in CT and SMA photography. We could analyze the branching patterns of middle hepatic artery (MHA) in 100 among 109 patients. MHA arising as a first branch of left hepatic artery was the most common pattern (50%), and MHA arising from proper hepatic artery separately on from left hepatic artery was the next common pattern (35%). MHA originating from left gastric artery, or from anterior or posterior of the right hepatic artery was not seen. MHA was not found as an accessory or replaced artery except as replaced common hepatic artery

  16. Effect of TIPS placement on portal and splanchnic arterial blood flow in 4-dimensional flow MRI

    Energy Technology Data Exchange (ETDEWEB)

    Stankovic, Zoran [Northwestern University, Department of Radiology, Feinberg School of Medicine, Chicago, IL (United States); University Medical Center Freiburg, Department of Diagnostic Radiology and Medical Physics, Freiburg (Germany); Roessle, Martin; Schultheiss, Michael [University Medical Center Freiburg, Department of Gastroenterology, Freiburg (Germany); Euringer, Wulf; Langer, Mathias [University Medical Center Freiburg, Department of Diagnostic Radiology and Medical Physics, Freiburg (Germany); Salem, Riad; Barker, Alex; Carr, James; Collins, Jeremy D. [Northwestern University, Department of Radiology, Feinberg School of Medicine, Chicago, IL (United States); Markl, Michael [Northwestern University, Department of Radiology, Feinberg School of Medicine, Chicago, IL (United States); Northwestern University, Department of Biomedical Engineering, McCormick School of Engineering, Chicago, IL (United States)

    2015-09-15

    To assess changes in portal and splanchnic arterial haemodynamics in patients undergoing transjugular intrahepatic portosystemic shunt (TIPS) using four-dimensional (4D) flow MRI, a non-invasive, non-contrast imaging technique. Eleven patients undergoing TIPS implantation were enrolled. K-t GRAPPA accelerated non-contrast 4D flow MRI of the liver vasculature was applied with acceleration factor R = 5 at 3Tesla. Flow analysis included three-dimensional (3D) blood flow visualization using time-resolved 3D particle traces and semi-quantitative flow pattern grading. Quantitative evaluation entailed peak velocities and net flows throughout the arterial and portal venous (PV) systems. MRI measurements were taken within 24 h before and 4 weeks after TIPS placement. Three-dimensional flow visualization with 4D flow MRI revealed good image quality with minor limitations in PV flow. Quantitative analysis revealed a significant increase in PV flow (562 ± 373 ml/min before vs. 1831 ± 965 ml/min after TIPS), in the hepatic artery (176 ± 132 ml/min vs. 354 ± 140 ml/min) and combined flow in splenic and superior mesenteric arteries (770 ml/min vs. 1064 ml/min). Shunt-flow assessment demonstrated stenoses in two patients confirmed and treated at TIPS revision. Four-dimensional flow MRI might have the potential to give new information about the effect of TIPS placement on hepatic perfusion. It may explain some unexpected findings in clinical observation studies. (orig.)

  17. Hepatic Artery Angiography and Embolization for Hemobilia Following Laparoscopic Cholecystectomy

    International Nuclear Information System (INIS)

    Nicholson, Tony; Travis, Simon; Ettles, Duncan; Dyet, John; Sedman, Peter; Wedgewood, Kevin; Royston, Christopher

    1999-01-01

    Purpose: The effectiveness of angiography and embolization in diagnosis and treatment were assessed in a cohort of patients presenting with upper gastrointestinal hemorrhage secondary to hepatic artery pseudoaneurysm following laparoscopic cholecystectomy. Methods: Over a 6-year period 1513 laparoscopic cholecystectomies were carried out in our region. Nine of these patients (0.6%) developed significant upper gastrointestinal bleeding, 5-43 days after surgery. All underwent emergency celiac and selective right hepatic artery angiography. All were treated by coil embolization of the right hepatic artery proximal and distal to the bleeding point. Results: Pseudoaneurysms of the hepatic artery adjacent to cholecystectomy clips were demonstrated in all nine patients at selective right hepatic angiography. In three patients celiac axis angiography alone failed to demonstrate the pseudoaneurysm. Embolization controlled hemorrhage in all patients with no further bleeding and no further intervention. One patient developed a candidal liver abscess in the post-procedure period. All patients are alive and well at follow-up. Conclusion: Selective right hepatic angiography is vital in the diagnosis of upper gastrointestinal hemorrhage following laparoscopic cholecystectomy. Embolization offers the advantage of minimally invasive treatment in unstable patients, does not disrupt recent biliary reconstruction, allows distal as well as proximal control of the hepatic artery, and is an effective treatment for this potentially life-threatening complication

  18. Evaluation of hepatic blood flow using 99mTc-GSA in rats with hepatic blood flow manipulation

    International Nuclear Information System (INIS)

    Hiraguchi, Etsuo

    1995-01-01

    Blood clearance and hepatic uptake parameters of 99m Tc-DTPA-galactosyl human serum albumin ( 99m Tc-GSA) were evaluated in two groups of rats, normal liver group and CCl 4 induced chronic liver injury group. In each group, four subgroups were classified as follows: simple laparotomy (LAP), hepatic artery ligation (HAL), portal vein ligation (PVL) and both hepatic artery and portal vein ligation (HAL+PVL). 99m Tc-GSA was intravenously injected (50 μg/100 g B.W.) to rats. Heart and liver were targetted as region of interest and time activity curves (TACs) were obtained. The blood clearance parameters (HH4 and Kd) and the hepatic uptake parameters (LHL4 and Ku) were calculated from these TACs. In normal liver group, the mean HH4 of LAP was significantly different from those of PVL and HAL+PVL. Similarly, the other three parameters (LHL4, Kd and Ku) of LAP were significantly different from those of PVL and HAL+PVL. CCl 4 induced chronic liver injury group showed significant difference on all four parameters in four subgroups. Hepatic tissue blood flow rates (HTBFR) calculated by Laser Doppler flowmeter correlated well with 99m Tc-GSA parameters in both groups. These results suggest that 99m Tc-GSA is useful to estimate hepatic blood flow not only in rats with normal liver, but also in rats with CCl 4 induced chronic liver injury. (author)

  19. Influence of transcatheter hepatic artery embolization using iodized oil on radiofrequency ablation of hepatic neoplasms

    International Nuclear Information System (INIS)

    Du Xilin; Ma Qingjiu; Wang Yiqing; Wang Zhimin; Zhang Hongxin

    2004-01-01

    Objective: To observe the effect of iodized oil on radiofrequency thermal ablation (RFA) of hepatic neoplasms by using a cluster array of ten separate electrodes. Methods: The patients were divided into 2 groups, group A with transcatheter hepatic artery embolization, group B without transcatheter hepatic artery embolization. All patients were undergone radiofrequency ablation of hepatic neoplasms. Results: The time of RFA for group A was (9 ± 2.1) minutes, showing the diameter of necrosis of (5.3 ± 1.4) cm. The time of RFA for group B was (16 ± 4. 6) minutes demonstrating the diameter of necrosis of (3.5 ± 1.8) cm (P<0.01). Conclusions: These findings suggest that radiofrequency thermal ablation of hepatic neoplasms with transcatheter hepatic artery embolization using iodized oil might improve the safety and synergic effect

  20. CT perfusion of the liver during selective hepatic arteriography. Pure arterial blood perfusion of liver tumor and parenchyma

    International Nuclear Information System (INIS)

    Komemushi, Atsushi; Tanigawa, Noboru; Kojima, Hiroyuki; Kariya, Shuji; Sawada, Satoshi

    2003-01-01

    The purpose of this study was to quantify pure arterial blood perfusion of liver tumor and parenchyma by using CT perfusion during selective hepatic arteriography. A total of 44 patients underwent liver CT perfusion study by injection of contrast medium via the hepatic artery. CT-perfusion parameters including arterial blood flow, arterial blood volume, and arterial mean transit time in the liver parenchyma and liver tumor were calculated using the deconvolution method. The CT-perfusion parameters and vascularity of the tumor were compared. A complete analysis could be performed in 36 of the 44 patients. For liver tumor and liver parenchyma, respectively, arterial blood flow was 184.6±132.7 and 41.0±27.0 ml/min/100 g, arterial blood volume was 19.4±14.6 and 4.8±4.2 ml/100 g, and arterial mean transit time was 8.9±4.2 and 10.2±5.3 sec. Arterial blood flow and arterial blood volume correlated significantly with the vascularity of the tumor; however no correlation was detected between arterial mean transit time and the vascularity of the tumor. This technique could be used to quantify pure hepatic arterial blood perfusion. (author)

  1. Combined resection of aberrant right hepatic artery without anastomosis in panceaticoduodenectomy for pancreatic head cancer: A case report.

    Science.gov (United States)

    Nanashima, Atsushi; Imamura, Naoya; Tsuchimochi, Yuki; Hiyoshi, Masahide; Fujii, Yoshiro

    2016-01-01

    This case report is intended to inform pancreas surgeons of our experience in operative management of aberrant pancreatic artery. A 63-year-old woman was admitted to our institute's Department of Surgery with obstructive jaundice, and the pancreas head tumor was found. To improve liver dysfunction, an endoscopic retrograde nasogastric biliary drainage tube was placed in the bile duct. Endoscopic fine-needle aspiration showed a pancreas head carcinoma invading the common bile duct, the aberrant right hepatic artery arising from the superior mesenteric artery, and the portal vein. Enhanced computed tomography showed the communicating artery between the right and left hepatic artery via the hepatic hilar plate. By way of imaging preoperative examination, a pancreaticoduodenectomy combined resection of the aberrant right hepatic artery and portal vein was conducted without arterial anastomosis. Hepatic arterial flow was confirmed by intraoperative Doppler ultrasonography, and R0 resection without tumor exposure at the dissected plane was achieved. The patient's postoperative course was uneventful. In this case report, perioperative detail examination by imaging diagnosis with respect to hepatic arterial communication to achieve curative resection in a pancreas head cancer was necessary. Non-anastomosis of hepatic artery was achieved, and the necessity of R0 resection was stressed by such management. By the preoperative and intraoperative imaging managements conducted, combined resection of the aberrant right hepatic artery without anastomosis was achieved by pancreaticoduodenectomy for pancreas head cancer. However, improvements in imaging diagnosis and careful management of R0 resection are important. Copyright © 2016 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  2. Spontaneous Hepatic Rupture Associated with Preeclampsia: Treatment with Hepatic Artery Embolization

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Seung Boo; Goo, Dong Erk; Chang, Yun Woo; Kim, Yong Jae; Hwang, In Cheol; Han, Hyo Sang; Yoon, Jong Hyun; Lee, Tae Il [Soonchunhyang University Hospital, Gumi (Korea, Republic of)

    2010-02-15

    Spontaneous rupture of the liver due to preeclampsia is a rare condition of pregnant women, and it can be very dangerous if not treated. We report here on a case of successfully treating spontaneous liver rupture associated with preeclampsia by performing transcatheter hepatic arterial embolization. A 41-year-old woman with spontaneous rupture of the liver associated with preeclampsia was treated by hepatic arterial embolization

  3. Spontaneous Hepatic Rupture Associated with Preeclampsia: Treatment with Hepatic Artery Embolization

    International Nuclear Information System (INIS)

    Yang, Seung Boo; Goo, Dong Erk; Chang, Yun Woo; Kim, Yong Jae; Hwang, In Cheol; Han, Hyo Sang; Yoon, Jong Hyun; Lee, Tae Il

    2010-01-01

    Spontaneous rupture of the liver due to preeclampsia is a rare condition of pregnant women, and it can be very dangerous if not treated. We report here on a case of successfully treating spontaneous liver rupture associated with preeclampsia by performing transcatheter hepatic arterial embolization. A 41-year-old woman with spontaneous rupture of the liver associated with preeclampsia was treated by hepatic arterial embolization

  4. Experimental research of covered stent implanted in canine hepatic artery

    International Nuclear Information System (INIS)

    Zhou Bing; Liu Linxiang; Li Minghua; Wang Yongli; Cheng Yongde

    2007-01-01

    Objective: To evaluate the feasibility of success rate of implantation, post-procedure stenosis rate, apposition ability and endothelialization level, etc. for implantation with balloon-expandable covered stent in canine hepatic artery. Methods: 8 adult canines were implanted with balloon-expendable stents covered by expandable poly Teflon ester membrane (e-PTFEM). Follow-up DSA was performed immediately, 2, 4 and 12 wk after the procedure. The canines were sacrificed for histopathologic examination and statistical analysis with correlation of implantation manenvor and angiographic manifestations. Results: 8 cases were all implanted with the covered stents in proper hepatic artery/right hepatic artery successfully; showing good apposition ability and non-opacification of the separated branches. 2 cases showed intraluminal obvious stenosis( > 50%)of the stent at 2 weeks follow-up, so did 3 cases at 12 weeks follow-up, and the total stenosis rate was 37.5% and 5 cases manifested full endothelialization (3 different locations of the sample all manifested full endothelialization), 3 cased manifested partial endothelialization (at least 1 location of the sample didn't show full endothelialization), and the two terminal parts were easier to get endothelialization than the central part. Before and after the stent implantation, hepatic function of all cases didn't demonstrate any obvious changes. Conclusions: Balloon-expandable covered stent can be implanted in canine hepatic artery. successfully, with good apposition ability, full endothelialization, and no influence on hepatic function. (authors)

  5. Implication of the presence of a variant hepatic artery during the Whipple procedure.

    Science.gov (United States)

    Rubio-Manzanares-Dorado, Mercedes; Marín-Gómez, Luis Miguel; Aparicio-Sánchez, Daniel; Suárez-Artacho, Gonzalo; Bellido, Carmen; Álamo, José María; Serrano-Díaz-Canedo, Juan; Padillo-Ruiz, Francisco Javier; Gómez-Bravo, Miguel Ángel

    2015-07-01

    The anatomical variants of the hepatic artery may have important implications for pancreatic cancer surgery. The aim of our study is to compare the outcome following a pancreatoduodenectomy (PD) in patients with or without a variant hepatic artery arising from superior mesenteric artery. We reviewed 151 patients with periampullary tumoral pathology. All patients underwent oncological PD between January 2005 and February 2012. Our series was divided into two groups: Group A: Patients with a hepatic artery arising from superior mesenteric artery; and Group B: Patients without a hepatic artery arising from superior mesenteric artery. We expressed the results as mean +/- standard deviation for continuous variables and percentages for qualitative variables. Statistical tests were considered significant if p < 0.05. We identified 11 patients with a hepatic artery arising from superior mesenteric artery (7.3%). The most frequent variant was an aberrant right hepatic artery (n = 7), following by the accessory right hepatic artery (n = 2) and the common hepatic artery trunk arising from the superior mesenteric artery (n = 2). In 73% of cases the diagnosis of the variant was intraoperative. R0 resection was performed in all patients with a hepatic artery arising from superior mesenteric artery. There were no significant differences in the tumor resection margins and the incidence of postoperative complications. Oncological PD is feasible by the presence of a hepatic artery arising from superior mesenteric artery. The complexity of having it does not seem to influence in tumor resection margins, complications and survival.

  6. Evaluation of hepatic atrophy after transcatheter arterial embolization

    International Nuclear Information System (INIS)

    Chung, Hwan Hoon; Lee, Mee Ran; Oh, Min Cheol; Park, Chul Min; Seol, Hae Young; Cha, In Ho

    1995-01-01

    Hepatic atrophy has been recognized as a complication of hepatic and biliary disease but we have often found it in follow up CT after transcatheter arterial embolization (TACE). The purpose of this study is to evaluate the characteristics of hepatic atrophy after TACE. Of 53 patients who had TACE. We evaluated the relationship between the incidence of hepatic atrophy and the number of TACE, and also evaluated the average number of TACE in patients with hepatic atrophy. Of 20 patients who had received more than average number of TACE for development of hepatic atrophy (2 times with portal vein obstruction, 2.7 times without portal vein obstruction in this study), we evaluated the relationship between the lipiodol uptake pattern of tumor and the incidence of hepatic atrophy. There were 8 cases of hepatic atrophy (3 with portal vein obstruction, 5 without portal vein obstruction), average number for development of hepatic atrophy were 2.5 times. As the number of TACE were increased, the incidence of hepatic atrophy were also increased. Of 20 patients who received more than average number of TACE for development of hepatic atrophy, we noted 6 cases of hepatic atrophy in 11 patients with dense homogenous lipiodol uptake pattern of tumor and noted only 1 case of hepatic atrophy in 9 patient with inhomogenous lipiodol uptake pattern. Hepatic atrophy was one of the CT findings after TACE even without portal vein obstruction. Average number of TACE was 2.5 times and risk factors for development of hepatic atrophy were portal vein obstruction, increased number of TACE, and dense homogenous lipiodol uptake pattern of tumor

  7. Establishment of a hepatic cirrhosis and portal hypertension model by hepatic arterial perfusion with 80% alcohol.

    Science.gov (United States)

    Wang, Lei; He, Fu-Liang; Liu, Fu-Quan; Yue, Zhen-Dong; Zhao, Hong-Wei

    2015-08-28

    To determine the feasibility and safety of establishing a porcine hepatic cirrhosis and portal hypertension model by hepatic arterial perfusion with 80% alcohol. Twenty-one healthy Guizhou miniature pigs were randomly divided into three experimental groups and three control groups. The pigs in the three experimental groups were subjected to hepatic arterial perfusion with 7, 12 and 17 mL of 80% alcohol, respectively, while those in the three control groups underwent hepatic arterial perfusion with 7, 12 and 17 mL of saline, respectively. Hepatic arteriography and direct portal phlebography were performed on all animals before and after perfusion, and the portal venous pressure and diameter were measured before perfusion, immediately after perfusion, and at 2, 4 and 6 wk after perfusion. The following procedures were performed at different time points: routine blood sampling, blood biochemistry, blood coagulation and blood ammonia tests before surgery, and at 2, 4 and 6 wk after surgery; hepatic biopsy before surgery, within 6 h after surgery, and at 1, 2, 3, 4 and 5 wk after surgery; abdominal enhanced computed tomography examination before surgery and at 6 wk after surgery; autopsy and multi-point sampling of various liver lobes for histological examination at 6 wk after surgery. In experimental group 1, different degrees of hepatic fibrosis were observed, and one pig developed hepatic cirrhosis. In experimental group 2, there were cases of hepatic cirrhosis, different degrees of increased portal venous pressure, and intrahepatic portal venous bypass, but neither extrahepatic portal-systemic bypass circulation nor death occurred. In experimental group 3, two animals died and three animals developed hepatic cirrhosis, and different degrees of increased portal venous pressure and intrahepatic portal venous bypass were also observed, but there was no extrahepatic portal-systemic bypass circulation. It is feasible to establish an animal model of hepatic cirrhosis and

  8. Rare Case of Vasculitis of the Hepatic Artery.

    Science.gov (United States)

    Mali, Padmavathi; Muduganti, Sudheer R; Goldberg, Jerry

    2015-12-01

    Vasculitis is an accumulation of inflammatory leucocytes in the blood vessels with reactive damage to mural structures. Isolated vasculitis of the gastrointestinal tract without systemic involvement is rare. We report a unique case of a female patient who presented with abdominal pain, and was found, on serology, to have elevated inflammatory markers without autoantibodies. A computed tomography scan of the abdomen and pelvis was suggestive of vasculitis of the hepatic artery. To the best of our knowledge, this is the first case, to date, of vasculitis of hepatic artery. © 2015 Marshfield Clinic.

  9. Aberrant hepatic arterial anatomy and the whipple procedure: lessons learned.

    Science.gov (United States)

    Chamberlain, Ronald S; El-Sedfy, Abraham; Rajkumar, Dhiraj

    2011-05-01

    Appreciation and study of hepatic arterial anatomical variability is essential to the performance of a pancreaticoduodenectomy to avoid surgical complications such as bleeding, hepatic ischemia/failure, and anastomotic leak/stricture. Awareness of this variability permits the surgeon to adapt the surgical technique to deal with anomalies identified preoperatively or intraoperatively thereby preventing unnecessary surgical morbidity and mortality. The objective of our study is to provide a comprehensive review of the anatomic arterial anomalies and discuss surgical strategies that will equip the surgeon to deal with all anomalies that may be encountered a priori or en passant during the course of a Whipple procedure.

  10. Hepatic arterial pseudoaneurysm: a rare complication of blunt abdominal trauma in children

    Energy Technology Data Exchange (ETDEWEB)

    Basile, K.E.; Sivit, C.J.; Sachs, P.B. [Department of Radiology, Rainbow Babies and Children`s Hospital of the University Hospitals of Cleveland, OH (United States); Stallion, A. [Department of Surgery, Rainbow Babies` and Children`s Hospital of the University Hospitals of Cleveland, OH (United States)

    1999-05-01

    We report a child who developed a hepatic artery pseudoaneurysm following blunt hepatic injury. This is a rare complication of hepatic trauma in children. The imaging evaluation and clinical management of hepatic artery pseudoaneurysms are presented. (orig.) With 3 figs., 8 refs.

  11. Anatomical variations of hepatic arterial system, coeliac trunk and renal arteries: an analysis with multidetector CT angiography.

    Science.gov (United States)

    Ugurel, M S; Battal, B; Bozlar, U; Nural, M S; Tasar, M; Ors, F; Saglam, M; Karademir, I

    2010-08-01

    The purpose of our investigation was to determine the anatomical variations in the coeliac trunk-hepatic arterial system and the renal arteries in patients who underwent multidetector CT (MDCT) angiography of the abdominal aorta for various reasons. A total of 100 patients were analysed retrospectively. The coeliac trunk, hepatic arterial system and renal arteries were analysed individually and anatomical variations were recorded. Statistical analysis of the relationship between hepatocoeliac variations and renal artery variations was performed using a chi(2) test. There was a coeliac trunk trifurcation in 89% and bifurcation in 8% of the cases. Coeliac trunk was absent in 1%, a hepatosplenomesenteric trunk was seen in 1% and a splenomesenteric trunk was present in 1%. Hepatic artery variation was present in 48% of patients. Coeliac trunk and/or hepatic arterial variation was present in 23 (39.7%) of the 58 patients with normal renal arteries, and in 27 (64.3%) of the 42 patients with accessory renal arteries. There was a statistically significant correlation between renal artery variations and coeliac trunk-hepatic arterial system variations (p = 0.015). MDCT angiography permits a correct and detailed evaluation of hepatic and renal vascular anatomy. The prevalence of variations in the coeliac trunk and/or hepatic arteries is increased in people with accessory renal arteries. For that reason, when undertaking angiographic examinations directed towards any single organ, the possibility of variations in the vascular structure of other organs should be kept in mind.

  12. Hepatic arterial embolization in the management of blunt hepatic trauma: indications and complications.

    Science.gov (United States)

    Letoublon, Christian; Morra, Irene; Chen, Yao; Monnin, Valerie; Voirin, David; Arvieux, Catherine

    2011-05-01

    The objective was to clarify the role of hepatic arterial embolization (AE) in the management of blunt hepatic trauma. Retrospective observational study of 183 patients with blunt hepatic trauma admitted to a trauma referral center over a 9-year period. The charts of 29 patients (16%) who underwent hepatic angiography were reviewed for demographics, injury specific data, management strategy, angiographic indication, efficacy and complications of embolization, and outcome. AE was performed in 23 (79%) of the patients requiring angiography. Thirteen patients managed conservatively underwent emergency embolization after preliminary computed tomography scan. Six had postoperative embolization after damage control laparotomy and four had delayed embolization. Arterial bleeding was controlled in all the cases. Sixteen patients (70%) had one or more liver-related complications; temporary biliary leak (n=11), intra-abdominal hypertension (n=14), inflammatory peritonitis (n=3), hepatic necrosis (n=3), gallbladder infarction (n=2), and compressive subcapsular hematoma (n=1). Unrecognized hepatic necrosis could have contributed to the late posttraumatic death of one patient. AE is a key element in modern management of high-grade liver injuries. Two principal indications exist in the acute postinjury phase: primary hemostatic control in hemodynamically stable or stabilized patients with radiologic computed tomography evidence of active arterial bleeding and adjunctive hemostatic control in patients with uncontrolled suspected arterial bleeding despite emergency laparotomy. Successful management of injuries of grade III upward often entails a combined angiographic and surgical approach. Awareness of the ischemic complications due to angioembolization is important.

  13. Stentgraft Implantation for the Treatment of Postoperative Hepatic Artery Pseudoaneurysm

    Energy Technology Data Exchange (ETDEWEB)

    Pedersoli, F., E-mail: fpedersoli@ukaachen.de; Isfort, P.; Keil, S.; Goerg, F.; Zimmermann, M.; Liebl, M.; Schulze-Hagen, M. [RWTH Aachen University Hospital, Department of Diagnostic and Interventional Radiology (Germany); Schmeding, M. [RWTH Aachen University Hospital, Clinic for General, Visceral and Transplant Surgery (Germany); Kuhl, C. K.; Bruners, P. [RWTH Aachen University Hospital, Department of Diagnostic and Interventional Radiology (Germany)

    2016-04-15

    PurposeHepatic artery pseudoaneurysms are a rare but potentially life-threatening complication of major pancreaticobiliary surgery. We evaluated the safety and efficacy of endovascular stentgraft implantation for the management of such vascular lesions.Materials and MethodsBetween May 2013 and October 2015, ten patients with postoperative hepatic artery pseudoaneurysm, of which eight presented with active hemorrhage, were treated with endovascular stentgraft implantation. All patients had undergone major pancreatic or hepatic surgery before (pylorus-preserving pancreaticoduodenectomy, pancreatectomy, hemihepatectomy, extended hemihepatectomy). The pseudoaneurysms were diagnosed 13–202 days after surgery and were associated with postsurgical complications (e.g., leakage of pancreaticojejunal anastomosis).ResultsIn 9/10 patients, the pseudoaneurysm was completely excluded via stentgraft implantation. In 1/10 patient, the pseudoaneurysm ruptured during the procedure and was successfully treated by immediate open surgery. In 1/10 patient, a second intervention was performed after 6 days because of rebleeding; this was successfully treated by implantation of a second overlapping stentgraft. Mean follow-up time is 51 days. None of the patients died due to stentgraft- or aneurysm-related complications. Further episodes of hemorrhage were not observed. In one patient, clinically asymptomatic complete occlusion of the stentgraft was discovered at follow-up imaging.ConclusionStentgraft implantation is a safe and effective technique to treat hepatic artery pseudoaneurysms related to major pancreatic or hepatic surgery, especially in the setting of acute hemorrhage.

  14. Stentgraft Implantation for the Treatment of Postoperative Hepatic Artery Pseudoaneurysm

    International Nuclear Information System (INIS)

    Pedersoli, F.; Isfort, P.; Keil, S.; Goerg, F.; Zimmermann, M.; Liebl, M.; Schulze-Hagen, M.; Schmeding, M.; Kuhl, C. K.; Bruners, P.

    2016-01-01

    PurposeHepatic artery pseudoaneurysms are a rare but potentially life-threatening complication of major pancreaticobiliary surgery. We evaluated the safety and efficacy of endovascular stentgraft implantation for the management of such vascular lesions.Materials and MethodsBetween May 2013 and October 2015, ten patients with postoperative hepatic artery pseudoaneurysm, of which eight presented with active hemorrhage, were treated with endovascular stentgraft implantation. All patients had undergone major pancreatic or hepatic surgery before (pylorus-preserving pancreaticoduodenectomy, pancreatectomy, hemihepatectomy, extended hemihepatectomy). The pseudoaneurysms were diagnosed 13–202 days after surgery and were associated with postsurgical complications (e.g., leakage of pancreaticojejunal anastomosis).ResultsIn 9/10 patients, the pseudoaneurysm was completely excluded via stentgraft implantation. In 1/10 patient, the pseudoaneurysm ruptured during the procedure and was successfully treated by immediate open surgery. In 1/10 patient, a second intervention was performed after 6 days because of rebleeding; this was successfully treated by implantation of a second overlapping stentgraft. Mean follow-up time is 51 days. None of the patients died due to stentgraft- or aneurysm-related complications. Further episodes of hemorrhage were not observed. In one patient, clinically asymptomatic complete occlusion of the stentgraft was discovered at follow-up imaging.ConclusionStentgraft implantation is a safe and effective technique to treat hepatic artery pseudoaneurysms related to major pancreatic or hepatic surgery, especially in the setting of acute hemorrhage.

  15. Radionuclide study on hepatic blood flow in Schistosomiasis Japonica

    Energy Technology Data Exchange (ETDEWEB)

    Okada, Junichi; Uchiyama, Guio; Hayakawa, Kazushige; Hayashi, Sanshin; Araki, Tsutomu; Arai, Takao; Iuchi, Masahiko

    1986-11-01

    Schistosomiasis Japonica is a regional disease found in elderly people who were living in once-endemic areas in Japan. Yamanashi was one of these areas until 1970, since when no newly infected patients were reported. The disease is characteristic of developing irreversible interstitial fibrosis of the liver, where parasites migrate and lay eggs. Portal hypertension, esophageal varices and hepatocellular carcinomas are the common features of the results. In order to estimate patient's hepatic blood flow, radionuclide angiography of the liver with the use of 10 - 15 millicuries of Tc-99m phytate were performed prior to the conventional multiview imaging. Twenty-two patients with schistosomiasis and twelve adults without evidence of liver disease were studied. A time-activity curve of the right lobe of the liver was generated by a computer, and the ratio of arterial blood flow to portal blood flow was calculated. As a result, a good correlation was found between the arterial to portal blood flow ratio and the grade of hepatic fibrosis verified by laparoscopic biopsy. The development of esophageal varices were likely to correlate well with the blood flow ratio rather than scores on the conventional static liver and spleen scintigram. The study was useful for evaluating patient's clinical stages and prognosis.

  16. Radionuclide study on hepatic blood flow in Schistosomiasis Japonica

    International Nuclear Information System (INIS)

    Okada, Junichi; Uchiyama, Guio; Hayakawa, Kazushige; Hayashi, Sanshin; Araki, Tsutomu; Arai, Takao; Iuchi, Masahiko.

    1986-01-01

    Schistosomiasis Japonica is a regional disease found in elderly people who were living in once-endemic areas in Japan. Yamanashi was one of these areas until 1970, since when no newly infected patients were reported. The disease is characteristic of developing irreversible interstitial fibrosis of the liver, where parasites migrate and lay eggs. Portal hypertension, esophageal varices and hepatocellular carcinomas are the common features of the results. In order to estimate patient's hepatic blood flow, radionuclide angiography of the liver with the use of 10 - 15 millicuries of Tc-99m phytate were performed prior to the conventional multiview imaging. Twenty-two patients with schistosomiasis and twelve adults without evidence of liver disease were studied. A time-activity curve of the right lobe of the liver was generated by a computer, and the ratio of arterial blood flow to portal blood flow was calculated. As a result, a good correlation was found between the arterial to portal blood flow ratio and the grade of hepatic fibrosis verified by laparoscopic biopsy. The development of esophageal varices were likely to correlate well with the blood flow ratio rather than scores on the conventional static liver and spleen scintigram. The study was useful for evaluating patient's clinical stages and prognosis. (author)

  17. Left bronchial artery arising from a replaced left hepatic artery in a patient with massive hemoptysis

    Energy Technology Data Exchange (ETDEWEB)

    Khil, Eun Kyung; Lee, Jae Myung [Dept. of Radiology, Soonchunhyang University College of Medicine, Bucheon Hospital, Bucheon (Korea, Republic of)

    2015-09-15

    A 70-year-old man with a 3-year history of bronchiectasis presented with massive hemoptysis that had lasted for 3 days. In our attempt to perform bronchial artery embolization, upper abdominal angiography was required to locate the left bronchial artery, which in this case was of anomalous origin, arising from a replaced left hepatic artery, which arose from the left gastric artery-a very unusual anatomical variant. We performed embolization with polyvinyl alcohol particles, and the patient's symptoms resolved completely, with no additional complications after conservative treatment.

  18. A preliminary discussion of angiographic anatomy and variations of rabbit hepatic vessels and catheterization methods of hepatic artery

    International Nuclear Information System (INIS)

    Wang Diaodong; Yang Renjie; Zhang Hongzhi; Sun Hongliang

    2006-01-01

    Objective: To study the normal angiographic anatomy and variations of rabbit hepatic vessels, and explore the optimal method for hepatic artery catheterization. Methods: 30 rabbits were divided into two groups randomly. Modified surgical method and interventional method were used to catheterize hepatic artery respectively, and followed by angiography to demonstrate the normal anatomy and variations of rabbit celiac artery, hepatic artery and portal vein. Results: The route and distribution of rabbit celiac artery and hepatic artery were very different from human's. The commonly seen variation showed the differences in branching bifurcation of hepatic-gastric artery, with the incidence of 13.3%. The rates of successfully hepatic artery catheterization with surgical and interventional methods were 86.6%(13/15) and 80%(12/15) respectively (P>0.05). The surgical method will not be successful, whenever there's variation. Conclusion: The normal anatomy and variation of rabbit celiac artery and hepatic artery are quite different from human's. Both surgical and interventional catheterizations could be rather successful but possessing advantages and disadvantages of each its own. (authors)

  19. Hepatic Falciform Ligament Artery in Patients with Chronic Liver Diseases: Detection on Computed Tomography Hepatic Arteriography

    International Nuclear Information System (INIS)

    Tajima, T.; Yoshimitsu, K.; Irie, H.; Nishie, A.; Hirakawa, M.; Ishigami, K.; Ushijima, Y.; Okamoto, D.; Honda, H.

    2009-01-01

    Background: The detection rate of hepatic falciform ligament artery (FLA) has been reported as ranging from 2-25%. The rate of FLA on laparotomy, however, is reported to be higher, at 68%. Purpose: To compare the detection rate of FLA on computed tomography hepatic arteriography (CTHA) with that on angiography and dynamic CT, and to clarify the clinical significance of FLA in patients with chronic liver disease. Material and Methods: 126 consecutive patients underwent CTHA angiography and dynamic CT to evaluate suspected liver tumors. Liver function was classified as follows: normal, n=5; Child-Pugh class A, n=94; B, n=21; and C, n=6. All CT images were obtained using multidetector (MDCT) scanners (Aquilion; Toshiba, Tokyo (JP)). For CTHA, CT images were obtained during contrast material injection through the left hepatic, proper, or common hepatic artery. On CT, FLAs were retrospectively identified within the hepatic falciform ligament and the hepatic round ligament by the paging method on a workstation (TWS-5000; Toshiba, Tokyo (JP)). The detection rates were compared among the three modalities (hepatic arterial phase of dynamic CT, CTHA, and angiography). The calibers of FLA were also correlated with the hepatic function of the patients. Results: The detection rates of FLA by angiography, dynamic CT, and CTHA were 37% (47/126), 10% (13/126), and 77% (97/126), respectively. The calibers of FLA increased as the hepatic function deteriorated (P=0.001). Conclusion: The detection rates of FLA with CTHA are far higher than those with angiography and dynamic CT. Careful interpretation with recognition of FLA on CTHA images is important, as inadvertent embolization or chemotherapeutic infusion of the FLA may result in supraumbilical skin rash

  20. Topography of the accessory left gastric artery (ALGA) analyzed by CT angiography from the left hepatic artery

    International Nuclear Information System (INIS)

    Shioyama, Yasukazu; Takasaka, Isao; Onaya, Hiroaki

    2003-01-01

    To avoid gastric complications when we perform transcatheter treatment via left hepatic artery, we analyzed the topography of ALGA (accessory left gastric artery) by left hepatic arteriography and CT angiography from left hepatic artery. Six hundred seventy eight cases of CT angiography were performed between 1995 and 2000. Among them, selective left hepatic arteriography was done in 85 cases. We analyzed the frequency and the course of ALGA on the hepatic angiogram and CT angiogram. ALGA were identified in eighteen (21.2 %) of the 85 cases. We classified them into eleven cases of the proximal type and six cases of the distal type. When ALGA bifurcated from the left hepatic artery very close to the bifurcation of A2 (dorsolateral branch) and A3 (ventrolateral branch), we classified them as the distal type on hepatic angiogram. On the other hand, when ALGA bifurcated from the left hepatic artery apart from the bifurcation of A2 and A3 they were classified as the proximal type. In one rare case ALGA originated from the dorsolateral branch of the left hepatic artery. ALGA were classified as the distal and proximal types. Distal type of ALGA often overlapped dorsolateral branch of the left hepatic artery, and it was sometimes difficult to notice the existence of them. We should check the existence of ALGA on the arterial phase of dynamic CT before we plan to make a transcatheter treatment from the left hepatic artery. Then we can avoid gastric complications caused by a transcatheter treatment from the left hepatic artery. (author)

  1. Segmental hepatic artery at hepatic hilar area. Analysis by 3 dimensional integrated image of artery, portal vein and bile duct

    Energy Technology Data Exchange (ETDEWEB)

    Sakai, Hisamune; Okuda, Kouji; Yoshida, Jun; Kinoshita, Hisafumi; Aoyagi, Shigeaki [Kurume Univ., School of Medicine, Kurume, Fukuoka (Japan)

    2006-11-15

    Multiple individual variations in running and bifurcation of the hepatic artery, biliary duct and portal vein are known in hepatic hilar area. This paper describes the examination of such arterial variations by integrating the 3D images of those vessels obtained by multidetector-row CT (MDCT). Subjects are findings from 64 patients with cholangiocarcinoma, hepatocarcinoma or cholelithiasis. MDCT dynamic scanning, and percutaneous transhepatic biliary drainage-CT and/or drip infusion cholangiography-CT with the intravenous iopamidol and/or iotroxate megulumin, were done with GE LightSpeed Ultra 16 slice type equipment to compose the 3D images. Arterial variants of the bifurcation in the right and left lobe were found to be 18 cases/62 (29%) and 13/64 (20%), respectively. The left artery running at right side of portal venous umbilical region was seen in 9/64 (14%) and right artery running ''northward'', in 9/62 (14%). Previous realization of such individual 3D arterial variations as above is necessary for the precise microsurgery of the hilar area to preserve the essential vessel. (T.I.)

  2. Segmental hepatic artery at hepatic hilar area. Analysis by 3 dimensional integrated image of artery, portal vein and bile duct

    International Nuclear Information System (INIS)

    Sakai, Hisamune; Okuda, Kouji; Yoshida, Jun; Kinoshita, Hisafumi; Aoyagi, Shigeaki

    2006-01-01

    Multiple individual variations in running and bifurcation of the hepatic artery, biliary duct and portal vein are known in hepatic hilar area. This paper describes the examination of such arterial variations by integrating the 3D images of those vessels obtained by multidetector-row CT (MDCT). Subjects are findings from 64 patients with cholangiocarcinoma, hepatocarcinoma or cholelithiasis. MDCT dynamic scanning, and percutaneous transhepatic biliary drainage-CT and/or drip infusion cholangiography-CT with the intravenous iopamidol and/or iotroxate megulumin, were done with GE LightSpeed Ultra 16 slice type equipment to compose the 3D images. Arterial variants of the bifurcation in the right and left lobe were found to be 18 cases/62 (29%) and 13/64 (20%), respectively. The left artery running at right side of portal venous umbilical region was seen in 9/64 (14%) and right artery running ''northward'', in 9/62 (14%). Previous realization of such individual 3D arterial variations as above is necessary for the precise microsurgery of the hilar area to preserve the essential vessel. (T.I.)

  3. Downstream Hepatic Arterial Blood Pressure Changes Caused by Deployment of the Surefire AntiReflux Expandable Tip

    International Nuclear Information System (INIS)

    Rose, Steven C.; Kikolski, Steven G.; Chomas, James E.

    2013-01-01

    Purpose: The purpose of this work was to evaluate blood pressure changes caused by deployment of the Surefire antireflux expandable tip. The pressure measurements are relevant because they imply changes in hepatoenteric arterial blood flow within this liver compartment during hepatic artery delivery of cytotoxic agents. Methods: After positioning the Surefire antireflux system in the targeted hepatic artery, blood pressure was obtained initially with the tip collapsed (or through a femoral artery sheath), then again after the tip was expanded before chemoembolization or yttrium 90 ( 90 Y) radioembolization. Results: Eighteen patients with liver malignancy underwent 29 procedures in 29 hepatic arteries (3 common hepatic, 22 lobar, 4 segmental). Systolic, diastolic, and mean blood pressure were all decreased by a mean of 29 mm Hg (p = 0.000004), 14 mm Hg (p = 0.0000004), and 22 mm Hg (p = 0.00000001), respectively. Conclusion: When the Surefire expandable tip is deployed to prevent retrograde reflux of agents, it also results in a significant decrease in blood pressure in the antegrade distribution, potentially resulting in hepatopedal blood flow in vessels that are difficult to embolize, such as the supraduodenal arteries

  4. Implication of the presence of a variant hepatic artery during the Whipple procedure

    Directory of Open Access Journals (Sweden)

    Mercedes Rubio-Manzanares-Dorado

    2015-07-01

    Full Text Available Introduction: The anatomical variants of the hepatic artery may have important implications for pancreatic cancer surgery. The aim of our study is to compare the outcome following a pancreatoduodenectomy (PD in patients with or without a variant hepatic artery arising from superior mesenteric artery. Material and methods: We reviewed 151 patients with periampullary tumoral pathology. All patients underwent oncological PD between January 2005 and February 2012. Our series was divided into two groups: Group A: Patients with a hepatic artery arising from superior mesenteric artery; and Group B: Patients without a hepatic artery arising from superior mesenteric artery. We expressed the results as mean ± standard deviation for continuous variables and percentages for qualitative variables. Statistical tests were considered significant if p < 0.05. Results: We identified 11 patients with a hepatic artery arising from superior mesenteric artery (7.3%. The most frequent variant was an aberrant right hepatic artery (n = 7, following by the accessory right hepatic artery (n = 2 and the common hepatic artery trunk arising from the superior mesenteric artery (n = 2. In 73% of cases the diagnosis of the variant was intraoperative. R0 resection was performed in all patients with a hepatic artery arising from superior mesenteric artery. There were no significant differences in the tumor resection margins and the incidence of postoperative complications. Conclusion: Oncological PD is feasible by the presence of a hepatic artery arising from superior mesenteric artery. The complexity of having it does not seem to influence in tumor resection margins, complications and survival.

  5. Mirizzi syndrome associated with hepatic artery pseudoaneurysm: a case report

    Directory of Open Access Journals (Sweden)

    Anderson Oliver

    2008-11-01

    Full Text Available Abstract Introduction This is the first case report of Mirizzi syndrome associated with hepatic artery pseudoaneurysm. Case presentation A 54-year-old man presented with painful obstructive jaundice and weight loss. Computed tomography showed a hilar mass in the liver. Following an episode of haemobilia, angiography demonstrated a pseudoaneurysm of a branch of the right hepatic artery that was embolised. At surgery, a gallstone causing Mirizzi type II syndrome was found to be responsible for the biliary obstruction and a necrotic inflammatory mass and haematoma were found to be extending into the liver. The mass was debrided and drained, the obstructing stones removed and the bile duct drained with a t-tube. The patient made a full recovery. Conclusion This case highlights another situation where there may be difficulty in differentiating Mirizzi syndrome from biliary tract cancer.

  6. Evaluation of the angiographic findings for extrahepatic arterial supply to primary hepatic cancer and interventional therapy

    International Nuclear Information System (INIS)

    Wang Weiyu; Lv Weifu; Hou Changlong; Zhang Xingming; Zhang Zhengfeng; Lu Dong; Gao Zonggen

    2007-01-01

    Objective: To study the angiographic characteristics of extrahepatic arterial supply for primary hepatic cancer (PHC)and the significance of interventional therapy. Methods: 32 cases of primary. hepatic cancer were undertaken routine celiac arterial angiography and explored the extrahepatic arterial supply for the tumor, then followed by superselective transcatheter arterial chemoembolization (TACE). Results: 37 extrahepatic feeding arteries to hepatic cancers in 32 cases were found including 12 from superior mesenteric arteries(SMA), 9 right inferior phrenic arteries (RIPA), 1 left inferior phrenic arteries (LIPA), 2 pancreatic arterial arch, 1 right internal thoracic artery(RITA), 1 right intercostal artery(RICA), 6 left gastric arteries (LGA), 1 splenic artery, 2 omental arteries (OTA), 2 gastroduodenal arteries. The most common extrahepatic feeding arteries were originated from SMA and RIPA. The rest 33 were performed with superselective transcatheter arterial chemoembolization and the other 4 with only transcatheter arterial chemotherapeutic perfusion due to failure of superselective catheterization. Conclusion: The extrahepatic feeding artery is commonly seen with various kinds and also necessary for interventional treatment same as the primary ones for hepatic cancers. (authors)

  7. Hepaticocystic duct and a rare extra-hepatic "cruciate" arterial anastomosis: a case report

    Directory of Open Access Journals (Sweden)

    Abeysuriya Vasitha

    2008-02-01

    Full Text Available Abstract Introduction The variations in the morphological characteristics of the extra-hepatic biliary system are interesting. Case presentation During the dissection of cadavers to study the morphological characteristics of the extra-hepatic biliary system, a 46-year-old male cadaver was found to have drainage of the common hepatic duct drains directly into the gall bladder neck. The right and left hepatic ducts were not seen extra-hepatically. Further drainage of the bile away from the gallbladder and into the duodenum was provided by the cystic duct. Formation of the common bile duct by the union of the common hepatic duct and cystic duct was absent. Further more the right hepatic artery was found to be communicating with the left hepatic artery by a "bridging artery" after giving rise to the cystic artery. An accessory hepatic artery originated from the "bridging artery" forming a "cruciate" hepatic arterial anastomosis. Conclusion Combination of a Hepaticocystic duct and an aberrant variation in the extra-hepatic arterial system is extremely rare.

  8. Arterial secondary blood flow patterns visualized with vector flow ultrasound

    DEFF Research Database (Denmark)

    Pedersen, Mads Møller; Pihl, Michael Johannes; Hansen, Jens Munk

    2011-01-01

    This study presents the first quantification and visualisation of secondary flow patterns with vector flow ultrasound. The first commercial implementation of the vector flow method Transverse Oscillation was used to obtain in-vivo, 2D vector fields in real-time. The hypothesis of this study...... was that the rotational direction is constant within each artery. Three data sets of 10 seconds were obtained from three main arteries in healthy volunteers. For each data set the rotational flow patterns were identified during the diastole. Each data set contains a 2D vector field over time and with the vector angles...

  9. Evaluation of RI images of hepatic blood flow using Tc-99m PMT

    Energy Technology Data Exchange (ETDEWEB)

    Fujiwara, Hiromichi; Iwasaki, Naoya; Ichikawa, Kesato

    1988-03-01

    To evaluate the clinical significance of RI images of hepatic blood flow using Tc-99m-PMT, analysis of the RI images and estimation of hepatic blood flow were carried out in patients with various liver diseases (37 cases). After intravenous injection of Tc-99m-PMT, hepatic accumulation curve of ROI positioned at whole liver area and time activity curve of ROI positioned at celiac artery were obtained through scintillation camera images with the computer-analysed system. Hepatic blood flow coefficient (K) was calculated from the hepatic accumulation curve. Based on the differential curve calculated from the time activity curve, chronological images of arterial, portal, parenchymal and saturated parenchymal phases were obtained. Results ; 1) K was 0.50 + 0.04, 0.35 + 0.02 and 0.26 + 0.04/min in normal type, CH type and LC type respectively. These coefficients well correlated with clinical severity of hepatic diseases. 2) Perfusional phase images of the liver became poorer in accordance with progression of liver disease, while images of spleen, portal venous system and collateral channels were more clearly obtained in liver cirrhosis. This method was shown to have a potential to understanding of severity of liver disease and hepatic blood flow dynamics.

  10. An experimental study on combined transcatheter hepatic arterial embolization and retrograde hepatic venous embolization

    International Nuclear Information System (INIS)

    Wang Maoqiang; Zhang Jinshan; Xing Zhanhai

    1997-01-01

    The experimental study is aimed at achieving the effect of hepatic tumor and tumor-bearing lobar or segmental resection by using combined transcatheter hepatic arterial embolization and retrograde hepatic venous embolization (THAE-RHVE) in experimental study. THAE-RHVE was carried out in 8 mongrel dogs. Hepatic arterial embolization was performed by injecting lipiodol followed by gelatin sponge particles, following complete occlusion of the hepatic vein with balloon catheter. Retrograde hepatic venous embolization (RHVE) was then performed by injecting a mixture of absolute ethanol and meglumini diatrizoatis (MD) via the inflated balloon catheter. Ethanol and MD were combined with a ratio of 1:1. RHVE alone was performed in 4 dogs as control. The animals were followed up for 1∼8 weeks with liver function test, CT, gross and microscopic examinations. There was no technical failure or procedural complications. Transient elevation of AST and ALT levels was seen immediately in both groups after the procedure. Follow-up CT after 3 weeks showed dense lipiodol accumulation in the embolized lobe or segment and the corresponding portal branches in the THAE-RHVE animals. At 1 week after THAE-RHVE, complete coagulation necrosis was seen at histologic examination in the embolized lobe. The hepatic vein and portal branches of the embolized area had thickened walls and were filled with thrombus. At 2 weeks, granulomatous tissue and inflammatory cell infiltration surrounding the necrotic area could be seen. At 4∼8 weeks, marked atrophy of the embolized lobe was found, and the necrotic area was progressively reducing in size and being replaced by fibrosis. In the control group, incomplete segmental coagulated necrosis was seen and the necrosis area wa smaller than that of THAE-REVE. Hepatic lobectomy or segmentectomy can be achieved with THAE-RHVE. This new method is safe and easy, and may be useful in the treatment of HCC

  11. Hepatic perfusion during hepatic artery infusion chemotherapy: Evaluation with perfusion CT and perfusion scintigraphy

    International Nuclear Information System (INIS)

    Miller, D.L.; Carrasquillo, J.A.; Lutz, R.J.; Chang, A.E.

    1989-01-01

    The standard method for the evaluation of hepatic perfusion during hepatic artery infusion (HAI) chemotherapy is planar hepatic artery perfusion scintigraphy (HAPS). Planar HAPS was performed with 2 mCi of [99mTc] macroaggregated albumin infused at 1 ml/min and compared with single photon emission CT (SPECT) HAPS and with a new study, CT performed during the slow injection of contrast material through the HAI catheter (HAI-CT). Thirteen patients underwent 16 HAI-CT studies, 14 planar HAPS studies, and 9 SPECT HAPS studies. In 13 of 14 studies (93%) HAI-CT and planar HAPS were in complete agreement as to the perfusion pattern of intrahepatic metastases and normal liver. In nine studies where all modalities were performed, the findings identified by HAI-CT and planar HAPS agreed in all cases, whereas the results of two SPECT scans disagreed with the other studies. With respect to perfusion of individual metastases, 14 of 14 HAI-CT studies, 12 of 13 planar HAPS studies, and 9 of 9 SPECT HAPS studies correctly demonstrated the perfusion status of individual lesions as indicated by the pattern of changes in tumor size determined on CT obtained before and after the perfusion studies. Hepatic artery infusion CT was superior for delineation of individual metastases, particularly small lesions, and for the evaluation of nonperfused portions of the liver. Planar HAPS detected extrahepatic perfusion in four patients, and this was not detected by HAI-CT. We conclude that HAI-CT and scintigraphy are complementary techniques. Hepatic artery infusion CT has advantages for the evaluation of intrahepatic perfusion, and planar HAPS is superior to HAI-CT for the detection of extrahepatic perfusion

  12. Value of non-contrast sequences in magnetic resonance angiography of hepatic arterial vasculature

    Energy Technology Data Exchange (ETDEWEB)

    Kalra, Vivek B., E-mail: vivek.kalra@yale.edu [Department of Diagnostic Radiology, Yale School of Medicine, Box 208042, Tompkins East 2, 333 Cedar Street, New Haven, CT 06520-8042, United States of America (United States); Gilbert, John W., E-mail: jwgilbert@partners.org [Department of Radiology, Brigham and Women' s Hospital, Harvard Medical School, Francis Street, Boston, MA 02115, United States of America (United States); Krishnamoorthy, Saravanan, E-mail: sk3552@columbia.edu [Department of Radiology, Columbia University Medical Center, Milstein 3rd Fl, New York NY 10032 United States (United States); Cornfeld, Daniel, E-mail: daniel.cornfeld@yale.edu [Department of Diagnostic Radiology, Yale School of Medicine, Box 208042, Tompkins East 2, 333 Cedar St, New Haven, CT 06520-8042, United States of America (United States)

    2014-06-15

    Objective: To evaluate value of adding non-contrast MR angiographic sequence (In-Flow Inversion Recovery [IFIR]) to standard fat-suppressed T1-weighted postcontrast sequence (3D spoiled gradient echo [3D-GRE]) for evaluating hepatic arterial anatomy. Methods: Retrospective evaluation of 30 consecutive patients undergoing multiphase liver MRI. Individual vessels for IFIR/3D-GRE sequences were evaluated by two blinded readers using a four-point scale. Statistical analysis was performed using the Wilcoxon signed-rank test for vessel conspicuity between IFIR/3D-GRE sequences. Results: IFIR alone diagnostically imaged 8.1% of vessels, 3D-GRE alone 25.8%, 55.8% by both 3D-GRE/IFIR, and 10.3% of vessels by neither. Two patients with variant vascular anatomy were visualized with both sequences. Addition of IFIR to 3D-GRE resulted in statistically significant increase in arterial visualization (p < 0.001), 10% relative increase in identified vessels, and 3–5 mi increase in acquisition time for total scan time of 30–35 min. Conclusions: IFIR may be a useful adjunct to 3D-GRE in hepatic angiography without adding considerably to scan time. 10% more hepatic arteries were seen when combining information from IFIR/3D-GRE vs. 3D-GRE alone.

  13. Coil Embolization of an Arteriobiliary Fistula Caused by Hepatic Intra-Arterial Chemotherapy

    International Nuclear Information System (INIS)

    Takao, Hidemasa; Doi, Ippei; Makita, Kohzoh; Watanabe, Toshiaki

    2005-01-01

    Arteriobiliary fistula is a rare complication of hepatic intra-arterial chemotherapy. We report successful coil embolization of an arteriobiliary fistula. An 80-year-old woman underwent percutaneous placement of an indwelling catheter into the replaced right hepatic artery for intra-arterial chemotherapy of liver metastases. Coil embolization of the left hepatic artery was not performed. The patient complained of abdominal pain during intra-arterial chemotherapy. Angiography revealed a fistula between the replaced right hepatic artery and the common bile duct. The fistula was successfully treated by coil embolization via the indwelling catheter, and the indwelling catheter was removed. Although such complications usually herald the termination of intra-arterial chemotherapy, the patient underwent percutaneous implantation of a new catheter-port system, and intra-arterial chemotherapy was restarted

  14. Stabilization of a percutaneously implanted port catheter system for hepatic artery chemotherapy infusion

    International Nuclear Information System (INIS)

    Shindoh, Noboru; Ozaki, Yutaka; Kyogoku, Shinsuke; Yamana, Daigo; Sumi, Yukiharu; Katayama, Hitoshi

    1999-01-01

    A port catheter system for hepatic artery infusion chemotherapy was implanted percutaneously via the left subclavian artery in 41 patients for treatment of unresectable liver metastases. The catheter tip was inserted into the gastroduodenal artery (GDA), the end hole was occluded with a guidewire fragment, and a side-hole for infusion was positioned at the bifurcation of the proper hepatic artery and the GDA. The GDA was embolized with steel coils around the infusion catheter tip via a transfemoral catheter. This procedure is designed to reduce the incidence of hepatic artery occlusion and infusion catheter dislocation.

  15. N-butyl Cyanoacrylate Glue Embolization of Arterial Networks to Facilitate Hepatic Arterial Skeletonization before Radioembolization

    Energy Technology Data Exchange (ETDEWEB)

    Samuelson, Shaun D.; Louie, John D.; Sze, Daniel Y., E-mail: dansze@stanford.edu [Stanford University School of Medicine, Division of Interventional Radiology (United States)

    2013-06-15

    Purpose. Avoidance of nontarget microsphere deposition via hepatoenteric anastomoses is essential to the safety of yttrium-90 radioembolization (RE). The hepatic hilar arterial network may remain partially patent after coil embolization of major arteries, resulting in persistent risk. We retrospectively reviewed cases where n-butyl cyanoacrylate (n-BCA) glue embolization was used to facilitate endovascular hepatic arterial skeletonization before RE. Methods. A total of 543 RE procedures performed between June 2004 and March 2012 were reviewed, and 10 were identified where n-BCA was used to embolize hepatoenteric anastomoses. Arterial anatomy, prior coil embolization, and technical details were recorded. Outcomes were reviewed to identify subsequent complications of n-BCA embolization or nontarget RE. Results. The rate of complete technical success was 80 % and partial success 20 %, with one nontarget embolization complication resulting in a minor change in treatment plan. No evidence of gastrointestinal or biliary ischemia or infarction was identified, and no microsphere-related gastroduodenal ulcerations or other evidence of nontarget RE were seen. Median volume of n-BCA used was <0.1 ml. Conclusion. n-BCA glue embolization is useful to eliminate hepatoenteric networks that may result in nontarget RE, especially in those that persist after coil embolization of major vessels such as the gastroduodenal and right gastric arteries.

  16. CORRELATION BETWEEN UTERINE ARTERY FLOW VELOCITY ...

    African Journals Online (AJOL)

    CORRELATION BETWEEN UTERINE ARTERY FLOW VELOCITY WAVEFORMS AND ENDOMETRIAL HISTOPATHOLOGY IN WOMEN WITH PERIMENOPAUSAL AND POSTMENOPAUSAL BLEEDING. Dr. Ebtesam Saied, Dr. Ismail El Garhy(MD), Dr. Farid I. Hassan(MD), Dr. Adel-Gamil Abd-Allah, Abd El Shafy Ibrahim ...

  17. A gamma camera method to monitor the use of degradable starch microspheres in hepatic arterial chemotherapy

    International Nuclear Information System (INIS)

    Britten, A.; Fleming, J.; Flowerdew, A.; Hunt, T.; Taylor, I.; Ackery, D.

    1989-01-01

    A gamma camera method to quantify the haemodynamic effects of degradable starch microspheres (DSM) in intra arterial hepatic therapy is described. Results are presented from ten patients with colorectal liver metastases. Intra hepatic arterio venous shunting was present in 1 patient prior to DSM and in 2 subjects after three 300 mg DSM fractions. DSM reduced the rate of flow of injectate to the lung in all cases. Conversely, an increased rate of flow of injectate to gut or spleen occurred with 300 mg fractions of DSM in 7/9 cases. Lower dose DSM fractions are indicated. At 2-3 min after DSM injection the mean fraction of the activity retained in the liver was 0.22. A DSM induced enhancement of tumour relative to normal tissue perfusion was obtained in four out of five tumour regions identified. All indices showed a wide variation between patients and between individual DSM doses, and the high incidence of extra hepatic shunting confirms the need for monitoring when using intra arterial microspheres. (orig.)

  18. Selective arterial chemoembolization for hepatic metastases from medullary thyroid carcinoma.

    Science.gov (United States)

    Lorenz, Kerstin; Brauckhoff, Michael; Behrmann, Curd; Sekulla, Carsten; Ukkat, Jörg; Brauckhoff, Katrin; Gimm, Oliver; Dralle, Henning

    2005-12-01

    Hepatic metastases from medullary thyroid carcinoma (MTC) may impair quality of life by hypercalcitonemia-associated diarrhea and pain. In this prospective study, the effect of selective arterial chemoembolization (SACE) was evaluated. Eleven patients with hepatic metastases from MTC received 1 to 9 courses of SACE using epirubicine. Symptomatic, biochemical, and morphologic responses on SACE were recorded. Symptomatic response was observed in all symptomatic patients. However, biochemical and radiologic response occurred only in 6 patients. Liver function was not affected by SACE. One patient with unexpected concurrent pheochromocytoma metastases died after the first course. Development of side effects in the course was observed in 8 patients but were only World Health Organization grade 1. Patients' satisfaction with SACE was excellent. Long-term follow-up found 7 patients alive (1-72 months). Three patients died with tumor 6, 12, and 24 months after SACE, respectively. SACE provided good symptom palliation for the majority of patients with hepatic metastases from MTC. However, transient remission or stabilization of hepatic metastases resulted in only 60%. Further studies using a randomized protocol are required.

  19. Ischemic Cholangitis Caused by Transcatheter Hepatic Arterial Chemoembolization 10 Months After Resection of the Extrahepatic Bile Duct

    International Nuclear Information System (INIS)

    Hasegawa, Kiyoshi; Kubota, Keiichi; Aoki, Taku; Hirai, Ichiro; Miyazawa, Masashi; Ohtomo, Kuni; Makuuchi, Masatoshi

    2000-01-01

    We report a case of ischemic cholangitis that occurred after transcatheter hepatic arterial chemoembolization (TAE). Ten months prior to TAE the patient had undergone central bisegmentectomy for hepatocellular carcinoma with resection of the extrahepatic bile duct. Eleven days after TAE, he developed suppurative cholangitis and multiple organ failure. Prior surgical ligation of the peribiliary arteries around the extrahepatic bile duct followed by TAE was considered to have played a crucial role in the development of ischemic cholangitis. This case demonstrates the importance of blood flow from the peribiliary arteries for the survival of the biliary epithelium

  20. Tumor and liver drug uptake following hepatic artery and portal vein infusion

    International Nuclear Information System (INIS)

    Sigurdson, E.R.; Ridge, J.A.; Kemeny, N.; Daly, J.M.

    1987-01-01

    Anatomic dye injection studies of the blood supply of colorectal hepatic metastases suggest that tumors are supplied predominantly by the hepatic artery. Using 13 N amino acids with dynamic gamma camera imaging in patients with colorectal hepatic metastases, it has been shown that hepatic artery infusion results in a significantly greater nutrient delivery to tumor compared with portal vein infusion. However, direct measurements of drug levels in tumor following hepatic artery and portal vein infusion in humans have not previously been reported. Patients with metastatic colorectal cancer confined to the liver received fluorodeoxyuridine (FUdR) through the hepatic artery or through the portal vein. All patients had previously failed systemic chemotherapy. Five patients with hepatic artery catheters were matched (by age, serum lactic dehydrogenase levels, percent hepatic replacement, and tumor size) with five patients with portal vein catheters. At operation, 3 H-FUdR (1 microCi/kg) and /sup 99m/Tc-macroaggregated albumin (MAA) (6 mCi) were injected into the hepatic artery or portal vein. Liver and tumor biopsies were obtained two and five minutes later. 3 H and /sup 99m/Tc were measured per gram tissue by scintillation and gamma counting. The mean liver levels following hepatic artery infusion (23.9 +/- 11.4 nmol/g) and portal vein infusion (18.4 +/- 14.5 nmol/g) did not differ. However, the mean tumor FUdR level following hepatic artery infusion was 12.4 +/- 12.2 nmol/g, compared with a mean tumor FUdR level following portal vein infusion of 0.8 +/- 0.7 nmol/g (P less than .01). This low level of tumor drug uptake after portal vein infusion of FUdR predicts minimal tumor response to treatment via this route. Thus, regional chemotherapy for established colorectal hepatic metastases should be administered through the hepatic artery

  1. Hepatic artery embolization for treatment of patients with hereditary hemorrhagic telangiectasia and symptomatic hepatic vascular malformations

    Energy Technology Data Exchange (ETDEWEB)

    Chavan, Ajay [Hannover Medical School, Department of Diagnostic Radiology, Hannover (Germany); Klinikum Oldenburg, Department of Radiology and Nuclear Medicine, Oldenburg (Germany); Caselitz, Martin; Wagner, Siegfried; Manns, Michael [Hannover Medical School, Department of Gastroenterology and Hepatology, Hannover (Germany); Gratz, Karl-Friedrich [Hannover Medical School, Department of Nuclear Medicine, Hannover (Germany); Lotz, Joachim; Kirchhoff, Timm; Galanski, Michael [Hannover Medical School, Department of Diagnostic Radiology, Hannover (Germany); Piso, Plinio [Hannover Medical School, Department of Abdominal and Transplantation Surgery, Hannover (Germany)

    2004-11-01

    At present there is no established therapy for treating patients with hereditary hemorrhagic telangiectasia (HHT) and symptomatic hepatic involvement. We present the results of a prospective study with 15 consecutive patients who were treated with staged hepatic artery embolization (HAE). Branches of the hepatic artery were selectively catheterized and embolized in stages using polyvinyl alcohol particles (PVA) and platinum microcoils or steel macrocoils. Prophylactic antibiotics, analgesics and anti-emetics were administered after every embolization. Clinical symptomatology and cardiac output were assessed before and after therapy as well as at the end of follow-up (median 28 months; range 10-136 months). Five patients had abdominal pain and four patients had symptoms of portal hypertension. The cardiac output was raised in all patients, with cardiac failure being present in 11 patients. After treatment, pain resolved in all five patients, and portal hypertension improved in two of the four patients. The mean cardiac output decreased significantly (P<0.001) from 12.57{+-}3.27 l/min pre-treatment to 8.36{+-}2.60 l/min at the end of follow-up. Symptoms arising from cardiac failure resolved or improved markedly in all but one patient. Cholangitis and/or cholecystitis occurred in three patients of whom two required a cholecystectomy. One patient with pre-existent hepatic cirrhosis died as a complication of the procedure. Staged HAE yields long-term relief of clinical symptoms in patients with HHT and hepatic involvement. Patients with pre-existing hepatic cirrhosis may be poor candidates for HAE. (orig.)

  2. Hepatocellular carcinoma with extensive hepatic artery injury: transcatheter arterial chemoembolization through collaterals after coil embolizatoin of gastric arteries

    International Nuclear Information System (INIS)

    Kim, Gab Choul; Yoon, Hyun Ki; Hwang, Jae Cheol; Lee, Duck Hee; Song, Ho Young; Suh, Dong Jin; Lee, Yung Sang; Chung, Young Hwa; Sung, Gyu Bo; Ko, Ki Young

    1999-01-01

    To evaluate the efficacy and safety of transcatheter arterial chemoembolization(TACE) after coil embolization of the gastroduodenal artery in hepatocellular carcinoma cases with multiple collateral arteries caused by proper hepatic artery injury. Between March 1997 and November 1998, a prospective trial of transcatheter arterial chemoembolization (TACE) was performed through collaterals from the gastroduodenal artery of 31 hepatocellular carcinoma patients with extensive proper hepatic artery injury due to repeated TACE. Among this number, 16 (group A) underwent TACE after coil embolization of the right gastric and gastroduodenal artery. The other 15 patients (group B) underwent TACE without coil embolization. The two groups had the same TNM stage and Clild-Pugh status. During the follow-up period, group A underwent additional TACE 3.3 times, and group B 2.8 times. The therapeutic effect of TACE was evaluated with computed tomography and by measuring alpha-fetoprotein levels. Complications were evaluated by means of gastrofibroscopy, laboratory data, and evaluation of the patients' clinical symptoms. The results obtained after six months and one year were compared within and between each group. At six months follow-up, CT findings had improved or were unchanged in 11 patients(69 %) in group A, and four patients(27 %) in group B(p = 0.032). In ten patients in each group, the level of alpha-fetoprotein was above 200 ng/ml. Its level was decreased in five patients(50 %) and three patients(30 %), respectively. The six-month survival rate was 81 % (13/16) in group A and 67% (10/15) in group B (p 0.43), while the one-year survival figures for these two groups were 50 % (8/16) and 20 % (3/15), respectively(p = 0.135). In group A, the CT findings were steady in five out of eight patients(63 %), while in groupB, CT findings showed that tumors with increased alpha-fetoprotein levels had increased in size and/or number. In group A, it was found that in two (33 %) of six

  3. Hepatocellular carcinoma with extensive hepatic artery injury: transcatheter arterial chemoembolization through collaterals after coil embolizatoin of gastric arteries

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Gab Choul; Yoon, Hyun Ki; Hwang, Jae Cheol; Lee, Duck Hee; Song, Ho Young; Suh, Dong Jin; Lee, Yung Sang; Chung, Young Hwa; Sung, Gyu Bo [Ulsan Univ. College of Medicine, Seoul (Korea, Republic of); Ko, Ki Young [Catholic Univ. College of Medicine, Seoul (Korea, Republic of)

    1999-09-01

    To evaluate the efficacy and safety of transcatheter arterial chemoembolization(TACE) after coil embolization of the gastroduodenal artery in hepatocellular carcinoma cases with multiple collateral arteries caused by proper hepatic artery injury. Between March 1997 and November 1998, a prospective trial of transcatheter arterial chemoembolization (TACE) was performed through collaterals from the gastroduodenal artery of 31 hepatocellular carcinoma patients with extensive proper hepatic artery injury due to repeated TACE. Among this number, 16 (group A) underwent TACE after coil embolization of the right gastric and gastroduodenal artery. The other 15 patients (group B) underwent TACE without coil embolization. The two groups had the same TNM stage and Clild-Pugh status. During the follow-up period, group A underwent additional TACE 3.3 times, and group B 2.8 times. The therapeutic effect of TACE was evaluated with computed tomography and by measuring alpha-fetoprotein levels. Complications were evaluated by means of gastrofibroscopy, laboratory data, and evaluation of the patients' clinical symptoms. The results obtained after six months and one year were compared within and between each group. At six months follow-up, CT findings had improved or were unchanged in 11 patients(69 %) in group A, and four patients(27 %) in group B(p = 0.032). In ten patients in each group, the level of alpha-fetoprotein was above 200 ng/ml. Its level was decreased in five patients(50 %) and three patients(30 %), respectively. The six-month survival rate was 81 % (13/16) in group A and 67% (10/15) in group B (p 0.43), while the one-year survival figures for these two groups were 50 % (8/16) and 20 % (3/15), respectively(p = 0.135). In group A, the CT findings were steady in five out of eight patients(63 %), while in groupB, CT findings showed that tumors with increased alpha-fetoprotein levels had increased in size and/or number. In group A, it was found that in two (33 %) of six

  4. Transcatheter hepatic arterial thermo-chemotherapy and thermo-lipiodol embolization for the treatment of hepatic metastases from colorectal carcinoma

    International Nuclear Information System (INIS)

    Wang Xuan; Chen Xiaofei

    2009-01-01

    Objective: To evaluate the clinical efficacy of transcatheter hepatic arterial thermo-chemotherapy and thermo-lipiodol embolization in the treatment of hepatic metastases from colorectal carcinoma. Methods: Sixty-eight cases with hepatic metastases from colorectal carcinoma were equally and randomly divided into two groups. The patients in study group were treated with transcatheter hepatic arterial thermo-chemotherapy and thermo-lipiodol embolization, while the patients in control group were treated with conventional (normal temperature) transcatheter hepatic arterial chemotherapy lipiodol embolization. Results: The effective rate of study group and control group was 65%(22/34) and 32%(11/34) respectively, the difference between two groups was statistically significant (P<0.05). No significant difference in the postoperative changes of hepatic function tests was found between the two groups. The survival rate at 6,12,18 and 24 months after the treatment was 100%, 82%, 44% and 18% respectively in study group, while it was 91%, 47%, 15% and 6% respectively in control group. Conclusion: Transcatheter hepatic arterial thermo-chemotherapy and thermo-lipiodol embolization is an effective and safe treatment for the hepatic metastases from colorectal carcinoma and has no obvious damage to the hepatic function. (authors)

  5. The use of coronary stent in hepatic artery stenosis after orthotopic liver transplantation

    International Nuclear Information System (INIS)

    Huang Mingsheng; Shan Hong; Jiang Zaibo; Li Zhengran; Zhu Kangshun; Guan Shouhai; Qian Jiesheng; Chen Guihua; Lu Minqiang; Yang Yang

    2006-01-01

    Purpose: This retrospective study was undertaken to evaluate the effectiveness of coronary stent placement in hepatic artery stenosis after orthotopic liver transplantation (OLT). Materials and methods: Of 430 consecutive adult orthotopic liver transplant recipients between November 2003 and September 2005, 17 had hepatic artery stenosis (HAS). Fourteen of them underwent coronary stent placement in the HAS. The technical results, complications, hepatic artery patency and clinical outcome were reviewed. Results: Technical and immediate success was 100%. After a mean follow-up of 159.4 days (range, 9-375 days), all patients obtained patent hepatic arteries except 2 patients occurred hepatic artery restenoses at 26 and 45 days after stent placement, respectively. Kaplan-Meier curve of patency showed cumulated stent patency at 3, 6, and 12 months of 78%, 58% and 45%, respectively. During the follow-up, 8 patients survived, 5 died of septic multiple-organ failure, 1 received retransplantation because of refractory biliary infection. Hepatic artery dissection induced by a guiding catheter occurred in one patient and was successfully treated with a coronary stent. Conclusion: Hepatic artery stenosis after OLT can be successfully treated with coronary stent placement with low complication rate and an acceptable 1-year hepatic artery patency rate

  6. CT findings in ischaemic hepatic failure due to intra-arterial embolisation: A case report

    International Nuclear Information System (INIS)

    Catalano, O.

    1997-01-01

    Liver infarction is relatively uncommon. It may be secondary to several conditions such as sepsis, shock, sickle-cell anaemia, eclampsia, vasculitis, metastatic disease, bacterial endocarditis, rheumatic heart disease, trauma, portal venous occlusion or compression, oral contraception, anaesthesia, hepatic artery thrombosis, therapeutical or inadvertent hepatic artery ligation, intra-arterial chemotherapy or embolisation. A case of hepatic infraction, unusual for iatrogenic pathogenesis, submassive extension with acute hepatic failure, and CT findings of an internally branching pattern due to intravascular gas was observed. (orig./AJ)

  7. Effect of hepatic blood flow alteration on the therapeutic effect of cryoablation in VX2 hepatic tumor rabbit: an experimental study

    International Nuclear Information System (INIS)

    Guo Zhi; Ni Hong; Li Baoguo; Hu Yonghua; Xing Wenge; Liu Fang

    2008-01-01

    Objective: To investigate the effect of alteration of blood flow in the hepatic artery on the therapeutic effect of cryoablation in VX2 hepatic tumor rabbit model. Methods: Thirty rabbits with VX2 hepatic tumor were divided into three groups according to hepatic artery blood flow: complete occlusion of the hepatic artery(group A), partial occlusion of the hepatic artery (group B), and no occlusion of the hepatic artery (group C). With conventional CT scan and perfusion scan, the values of blood flow (BF) and blood volume(BV) of VX 2 tumor were computed and the differences among the three groups were analyzed. After cryoablation, the animals were euthanized and the livers were removed. The hepatic tissue from the cryoablation area and surrounding area underwent both methyl thiazolyl tetrazolium (MTY) diaphorase staining and triphenyl tetrazolium chloride (TTC) staining. The gross pathology and histopathological changes were observed. Results: (1)The BF and BV in the three groups were: (7.23 + 2. 15 ) ml·100 g -1 ·min -1 and (1.63±0.52) ml/100 g in group A; (32.65±6.12) ml·100 g -1 ·min -1 and (9.32±2.63) ml/100 g in group B; (61.34±12.15) ml·100 g -1 ·min -1 and (17.51± 3.14) ml/100 g in group C, respectively. There were significant differences among the three groups in the BF and BV (F value was 452.16 and 421.33 in the BF and BV, respectively, P <0.01); (2) The maximum diameter of cryoablation-induced necrosis was (2.3±0.3)cm in group A, (1.5±0.2) cm in group B, and (0.8±0.1) cm in group C, respectively. The difference was significant among the groups (F value was 315.32,P <0.01). (3) There were well-defined frozen areas, bordering areas and normal surrounding areas in MTT staining. In group C, positive staining around some blood vessels could be seen. Conclusion: Alteration of the blood flow in the hepatic artery can affect the cryoablation efficacy. With the decrease of hepatic artery blood flow, the efficacy of cryoablation on liver tumor

  8. Hepatic artery stenosis in liver transplantation: Imaging and interventional treatment

    International Nuclear Information System (INIS)

    Rinaldi, Pierluigi; Inchingolo, Riccardo; Giuliani, Michela; Di Stasi, Carmine; De Gaetano, Anna Maria; Maresca, Giulia; Bonomo, Lorenzo

    2012-01-01

    Introduction: Main purpose of our study is to demonstrate the spectral and color Doppler ultrasonography (DUS) findings that would indicate hepatic artery stenosis (HAS) after liver transplantation and to report our single center results. Moreover we want to establish role and limits of the different imaging techniques in detecting HAS, proposing a non invasive diagnostic approach and to depict indications and feasibility of endovascular treatment in the single patient. Materials and methods: Our study consisted of 222 patients who underwent liver transplantation between January 1999 and December 2009. DUS findings were correlated with multidetector computed tomography angiography (MDCTA) and angiographic results. Results: HAS occurred in 21 cases (9.5%). In all cases diagnosis was performed by DUS. MDCTA quantified stenosis and showed an overall picture of splanchnic vascularization. Based on DUS and MDCTA data integration, in 9 cases we adopted the “wait and see” strategy. Moreover in 12 cases treatment was considered necessary. For hepatic artery stenosis, use of DUS criteria resulted in a sensitivity of 100% (20/20), a specificity of 99.5% (201/202), a positive predictive value (PPV) of 95% (20/21), and negative predictive value (NPV) of 100% (201/201), and an overall accuracy of 99.5% (221/222). Conclusion: Our study underline the role of DUS in early diagnosis of HAS: repeated evaluation of both direct and indirect signs increases NPV and sensitivity of DUS.

  9. Assessment of hepatic arterial variation using multidetector helical CT-angiography

    International Nuclear Information System (INIS)

    Lee, Dong Hoon; Lee, Jun Woo; Jun, Woong Bae; Lee, Suk Hong

    2001-01-01

    To evaluate the anatomy of the hepatic artery and normal variants using oblique thick-slab maximal intensity projection (MIP) 3-D CT angiography and multidetector helical CT technology. In 70 patients, axial three-phase CT together with multidetector helical CT and a nonionic contrast agent was used to evaluate liver disease. During the early arterial phase, the parameters were as follow: slice thickness, 2.5 mm; table speed, 15 mm/rotation, pitch, 6; contrast material, 4 ml/sec; total 120 ml. Using the MIP technique and an Advantage window voxtal 3.03 system (GE), the images obtained were reconstructed as 3D angiograms. In each case, the arterial anatomy and its variants were recorded. A typical anatomy was found in 53 cases (75.7%). Common variants were a left hepatic artery arising from the left gastric artery(8 cases, 11.4 %) and a right hepatic artery arising from the superior mesenteric artery(3 cases, 4.3%). Other variant cases were right hepatic artery arising from the gastroduodenal artery(2 cases, 2.9%), a proper hepatic artery arising from the left gastric artery (1 case, 1.4%), a hepatomesenteric trunk (1 case), a hepatogastric/splenomesenteric trunk(1 case), and a celiomesenteric trunk (1 case). 3-D hepatic angiography using multidetector helical CT technology is non-invasive and as accurate as conventional angiography for the evaluation of hepatic arterial anatomy. It is thus considered that 3-D CT angiography is very helpful for the evaluation of hepatic arterial anatomy prior to liver surgery such as transplantation or the treatment of hepatocellular carinoma

  10. Pulsatile spiral blood flow through arterial stenosis.

    Science.gov (United States)

    Linge, Fabian; Hye, Md Abdul; Paul, Manosh C

    2014-11-01

    Pulsatile spiral blood flow in a modelled three-dimensional arterial stenosis, with a 75% cross-sectional area reduction, is investigated by using numerical fluid dynamics. Two-equation k-ω model is used for the simulation of the transitional flow with Reynolds numbers 500 and 1000. It is found that the spiral component increases the static pressure in the vessel during the deceleration phase of the flow pulse. In addition, the spiral component reduces the turbulence intensity and wall shear stress found in the post-stenosis region of the vessel in the early stages of the flow pulse. Hence, the findings agree with the results of Stonebridge et al. (2004). In addition, the results of the effects of a spiral component on time-varying flow are presented and discussed along with the relevant pathological issues.

  11. Interventional therapy of hepatic arterial hemorrhage occurred after percutaneous transhepatic biliary drainage

    International Nuclear Information System (INIS)

    Liang Songnian; Feng Bo; Su Hongying; Xu Ke

    2011-01-01

    Objective: To analyze the causes and clinical manifestations of hepatic arterial hemorrhage which occurred after percutaneous transhepatic biliary drainage and to summarize the practical experience in its diagnosis and treatment in order to decrease its incidence and mortality. Methods: During the period from June 2007 to June 2010, percutaneous transhepatic biliary drainage was carried out in 622 cases, of which DSA-proved postoperative hepatic arterial hemorrhage occurred in 11, including bile duct hemorrhage (n=6), abdominal cavity bleeding (n=3) and combination of bile duct and abdominal cavity (n=2). Interventional embolization of the bleeding branches of hepatic artery with Gelfoam and coils was carried out in all 11 patients. The clinical data such as clinical manifestations and therapeutic results were retrospectively analyzed. Results: After interventional embolization therapy for postoperative hepatic arterial hemorrhage the bleeding stopped in ten patients, who were discharged from hospital when the clinical conditions were alleviated. The remaining one patient died of sustained deterioration in hepatic and renal functions although the bleeding was ceased. Conclusion: Though hepatic arterial hemorrhage occurred after percutaneous transhepatic biliary drainage is a rare complication, it is dangerous and fatal. Hepatic arterial angiography together with interventional embolization is a sate and effective therapy for hepatic arterial hemorrhage. (authors)

  12. Anatomical variation of celiac axis, superior mesenteric artery, and hepatic artery: Evaluation with multidetector computed tomography angiography

    Directory of Open Access Journals (Sweden)

    Maryam Farghadani

    2016-01-01

    Full Text Available Background: The celiac axis, superior mesenteric artery (SMA, and hepatic artery are the most important branches of abdominal aorta due to their vascularization field. The aim of our study was to evaluate the prevalence of different anatomical variation of celiac axis, SMA, hepatic artery, and its branches with multidetector computed tomography (MDCT angiography of upper abdomen arteries. Materials and Methods: MDCT of 607 kidney donor and traumatic patients that referred to MDCT unit at Al Zahra Hospital in Isfahan from 2012 to 2015 were retrospectively evaluated. We excluded patients with history of abdominal vascular surgery and hepatic or pancreatic surgery. Computed tomography images of the patient were obtained with 64-row MDCT scanner and anatomical variations were analyzed. Results: Three hundred and eighty-eight (63.9% of the 607 patients had classic arterial anatomy and 219 (36.1% patients had variant types. The most common type of variation was the origin of the right hepatic artery (RHA from SMA (9.6%, and the next common variation was the origin of the left hepatic artery (LHA from the left gastric artery (6.9%. Variations in the origin of the common hepatic artery (CHA were seen in 16 (2.6% patients. Buhler arc was identified in two patients. The RHA originated from the celiac axis in 11 (1.8% patients and from the aorta in 8 (1.3% patients. Trifurcation of CHA into gastroduodenal artery, RHA, and LHA was detected in 11 (1.8% patients. Conclusion: The results of the present study showed that anatomical variation occurs in a high percentage of patients. Detection of these variations can guide surgical and radiological interventional planning.

  13. Computed tomography angiography study of variations of the celiac trunk and hepatic artery in 100 patients

    Energy Technology Data Exchange (ETDEWEB)

    Brasil, Ivelise Regina Canito; Araujo, Igor Farias de; Lima, Adriana Augusta Lopes de Araujo; Melo, Ernesto Lima Araujo; Esmeraldo, Ronaldo de Matos, E-mail: igor_farias98@hotmail.com [Universidade Estadual do Ceará (UECE), Fortaleza, CE (Brazil). Escola de Medicina

    2018-01-15

    Objective: To describe the main anatomical variations of the celiac trunk and the hepatic artery at their origins. Materials and methods: This was a prospective analysis of 100 consecutive computed tomography angiography studies of the abdomen performed during a one-year period. The findings were stratified according to classification systems devised by Sureka et al. and Michels. Results: The celiac trunk was 'normal' (i.e., the hepatogastrosplenic trunk and superior mesenteric artery originating separately from the abdominal aorta) in 43 patients. In our sample, we identified four types of variations of the celiac trunk. Regarding the hepatic artery, a normal anatomical pattern (i.e., the proper hepatic artery being a continuation of the common hepatic artery and bifurcating into the right and left hepatic arteries) was seen in 82 patients. We observed six types of variations of the hepatic artery. Conclusion: We found rates of variations of the hepatic artery that are different from those reported in the literature. Our findings underscore the need for proper knowledge and awareness of these anatomical variations, which can facilitate their recognition and inform decisions regarding the planning of surgical procedures, in order to avoid iatrogenic intraoperative injuries, which could lead to complications. (author)

  14. Computed tomography angiography study of variations of the celiac trunk and hepatic artery in 100 patients

    Directory of Open Access Journals (Sweden)

    Ivelise Regina Canito Brasil

    Full Text Available Abstract Objective: To describe the main anatomical variations of the celiac trunk and the hepatic artery at their origins. Materials and Methods: This was a prospective analysis of 100 consecutive computed tomography angiography studies of the abdomen performed during a one-year period. The findings were stratified according to classification systems devised by Sureka et al. and Michels. Results: The celiac trunk was "normal" (i.e., the hepatogastrosplenic trunk and superior mesenteric artery originating separately from the abdominal aorta in 43 patients. In our sample, we identified four types of variations of the celiac trunk. Regarding the hepatic artery, a normal anatomical pattern (i.e., the proper hepatic artery being a continuation of the common hepatic artery and bifurcating into the right and left hepatic arteries was seen in 82 patients. We observed six types of variations of the hepatic artery. Conclusion: We found rates of variations of the hepatic artery that are different from those reported in the literature. Our findings underscore the need for proper knowledge and awareness of these anatomical variations, which can facilitate their recognition and inform decisions regarding the planning of surgical procedures, in order to avoid iatrogenic intraoperative injuries, which could lead to complications.

  15. Computed tomography angiography study of variations of the celiac trunk and hepatic artery in 100 patients

    International Nuclear Information System (INIS)

    Brasil, Ivelise Regina Canito; Araujo, Igor Farias de; Lima, Adriana Augusta Lopes de Araujo; Melo, Ernesto Lima Araujo; Esmeraldo, Ronaldo de Matos

    2018-01-01

    Objective: To describe the main anatomical variations of the celiac trunk and the hepatic artery at their origins. Materials and methods: This was a prospective analysis of 100 consecutive computed tomography angiography studies of the abdomen performed during a one-year period. The findings were stratified according to classification systems devised by Sureka et al. and Michels. Results: The celiac trunk was 'normal' (i.e., the hepatogastrosplenic trunk and superior mesenteric artery originating separately from the abdominal aorta) in 43 patients. In our sample, we identified four types of variations of the celiac trunk. Regarding the hepatic artery, a normal anatomical pattern (i.e., the proper hepatic artery being a continuation of the common hepatic artery and bifurcating into the right and left hepatic arteries) was seen in 82 patients. We observed six types of variations of the hepatic artery. Conclusion: We found rates of variations of the hepatic artery that are different from those reported in the literature. Our findings underscore the need for proper knowledge and awareness of these anatomical variations, which can facilitate their recognition and inform decisions regarding the planning of surgical procedures, in order to avoid iatrogenic intraoperative injuries, which could lead to complications. (author)

  16. Left hepatectomy combined with hepatic artery resection for hilar cholangiocarcinoma: A retrospective cohort study.

    Science.gov (United States)

    Peng, Chihan; Li, Chuan; Wen, Tianfu; Yan, Lvnan; Li, Bo

    2016-08-01

    those with non-severe jaundice (56.3%, 43.8%, 35% and 26.3% vs. 66.7%, 58.8%, 52.2% and 41.8%, P = 0.317; 50%, 42.9%, 35.7% and 13.4% vs. 63.8%, 54%, 35.6% and 21.3%, P = 0.753). Left hepatectomy combined with hepatic artery resection and no reconstruction for hilar cholangiocarcinoma is recommended when the following conditions are satisfied: 1) Bismuth-Corlette I, II, or IIIb hilar cholangiocarcinoma; 2) the tumor has infiltrated the hepatic artery with disappearance or markedly reduced arterial flow as detected by intraoperative ultrasound; 3) the color of the liver by visual observation does not change when the hepatic artery has been blocked for 5 min; and 4) removal of the tumor-infiltrated hepatic artery increases the probability of R0 resection for hilar cholangiocarcinoma. For obstructive jaundice from hilar cholangiocarcinoma, we recommend bile duct drainage before resection in patients with elevated preoperative serum TB. Copyright © 2016 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

  17. The Features of Extrahepatic Collateral Arteries Related to Hepatic Artery Occlusion and Benefits in the Transarterial Management of Liver Tumors

    International Nuclear Information System (INIS)

    Yang, Lin; Zhang, Xiao Ming; Ren, Yong Jun; Miao, Nan Dong; Huang, Xiao Hua; Dong, Guo Li

    2013-01-01

    Purpose. To investigate the extrahepatic collateral arteries related to hepatic artery occlusion (HAO) and to determine its benefits in the transarterial management of liver tumors. Methods and Findings. Eleven patients (7 hepatocellular carcinomas, 3 liver metastases, and 1 with hemangioma) with HAO confirmed with digital subtraction angiography (DSA) were admitted to our hospital. Of the 11 patients, 7 were men and 4 were women, with an average age of 41.5 ± 15.5 years (range: 29 to 70 years). DSA was performed to evaluate the collateral routes to the liver. In the 11 patients with HAO, DSA showed complete occlusion of the common hepatic artery in 9 patients and the proper hepatic artery (PHA) in 2 patients. Extrahepatic collateral arteries supplying the liver were readily evident. The collateral arteries originated from the superior mesenteric artery (SMA) in 8 patients, from the gastroduodenal artery in 2 patients, and from the left gastric artery (LGA) in 1 patient. Transcatheter treatment was successfully performed via the collateral artery in all patients except the one who had hemangioma. Conclusions. DSA is an effective method for detecting collateral circulation related to HAO and may provide information to guide transcatheter management decisions

  18. Hepatic blood flow with colloidal 198Au in the diagnosis of chronic hepatitis in children

    International Nuclear Information System (INIS)

    Marian, L.; Szantay, V.

    1975-01-01

    Tracer quantities of colloidal 198 Au were used to estimate the hepatic blood flow in normal children and in children with active or progressive chronic hepatitis and also to obtain scintigrams of the liver. In active chronic hepatitis a significant decrease in HBF values was observed, suggesting that the method may be used as a diagnostic criterion which is superior to hepatic scintigraphy. In progressive chronic hepatitis HBF values even lower than those in active hepatitis were observed. Together with more characteristic clinical findings and abnormal results of biochemical function tests, they underline the value of the method in estimating the severity and the evolution of the disease. (orig.) [de

  19. Concurrent Hepatic Artery and Portal Vein Thrombosis after Orthotopic Liver Transplantation with Preserved Allografts

    Directory of Open Access Journals (Sweden)

    Arshad Khan

    2014-01-01

    Full Text Available In contrast to early HAT, late HAT has an insidious clinical presentation. Nevertheless, biliary and vascular reconstructions in this late setting are unlikely to improve outcome. Patent portal flow makes an important contribution to the viability of liver in case of late HAT while the allograft reconstitutes intrahepatic arterial flow through neovascularization. Concurrent HAT with PVT without immediate graft necrosis is extremely rare, and allograft and patient survival are seemingly impossible without retransplantation. In fact, hepatopetal arterial and portal venous neovascularization are known albeit obscure phenomena that can preserve posttransplant hepatic function under the extenuating circumstances of complete interruption of blood flow to the graft. We describe two such cases that developed combined HAT and PVT more than six months after OLT with perfect preservation of graft function. The survival of allografts in our cases was due to extensive hepatopetal arterial and portal venous collateralization. Simultaneous HAT and PVT after OLT are rare events and almost uniformly fatal, if they occur early. Due to paucity of such cases, however, underlying mechanisms and etiology remain elusive, and despite radiological diagnosis of these complications, there is no way to predict these events in the wake of stable graft function.

  20. Development of a New Technique for Reconstruction of Hepatic Artery during Liver Transplantation in Sprague-Dawley Rat.

    Directory of Open Access Journals (Sweden)

    Xingmu Liu

    Full Text Available Sleeve anastomosis is the most common technique used to rearterialize orthotopic liver transplants (OLT. However, this technique has a number of disadvantages, including difficulty of performance of the technique visually unaided. We herein describe a novel rearterialized OLT model in the rat.Forty-six male Sprague Dawley rats (300-400 g were used as donors and recipients. Based on Kamada's cuff technique, the new model involved performing a modified "sleeve" anastomosis between the celiac trunk of the donor and common hepatic artery of the recipient to reconstruct blood flow to the hepatic artery. An additional ten male Sprague Dawley rats underwent liver transplantation without artery reconstruction. Liver grafts were retrieved from the two groups and histological examination was performed following surgery.Total mean operating times were ~42 minutes for the donor liver extraction and 57 minutes for the recipient transplantation. Graft preparation took an additional 15 minutes and the time to fix the arterial bracket was ~3 minutes. During transplantation, the anhepatic phase lasted 18 ± 2.5 min and the artery reconstruction only required ~3 minutes. The patency rate was 94.44% and the 4-week survival rate was 90%. Histology indicated obvious fibrosis in the liver grafts without artery reconstruction, while normal histology was observed in the arterialized graft.This new method allows for the surgical procedure to be performed visually unaided with good survival and patency rates and represents an alternative model investigating OLT in rats.

  1. Arteries of the falciform ligament on C-arm CT hepatic arteriography: The hepatic falciform artery and the Sappey's superior artery

    Energy Technology Data Exchange (ETDEWEB)

    Hur, Saebeom; Chung, Jin Wook; Lee, Jae Hwan; Cho, SooBeum; Kim, Minuk; Lee, Myungsu; Kim, Hyo-Cheol; Jae, Hwan Jun [Seoul National University Hospital, Department of Radiology, Seoul (Korea, Republic of); Zhou, Chun Gao [First Affiliated Hospital of Nanjing Medical University, Department of Interventional Radiology, Nanjing, Jangsu (China)

    2017-04-15

    To investigate the prevalence, anatomy and distribution of the hepatic falciform artery (HFA) and Sappey's superior artery (SSA) using C-arm CT hepatic arteriography (C-arm CTHA). From January 2011 to December 2012, 220 patients who underwent C-arm CTHA during initial transarterial treatment for hepatocellular carcinoma were included in this retrospective study. The HFAs and SSAs prevalence and origin were evaluated using axial images of C-arm CTHA. A 5-point scale for HFAs and a 4-point scale for SSAs were used to designate the radiologically conspicuous arteries. The prevalences of the total HFAs and SSAs were 95 % (n=209) and 22 % (n=49), while those of radiologically conspicuous HFAs and SSAs were 62 % (n=137) and 10 % (n=22), respectively. Thirty HFAs (22 % of radiologically conspicuous HFAs and 14 % of the total study population) were distributed in the subcutaneous layer of the anterior abdominal wall, while the majority of SSAs ran through the superior part of the falciform ligament in the left-anterior direction and anastomosed with left inferior phrenic artery. Our study using C-arm CTHA revealed that the prevalence of the HFA is higher than the existing knowledge and proved the existence of the SSA radiologically for the first time. (orig.)

  2. Arteries of the falciform ligament on C-arm CT hepatic arteriography: The hepatic falciform artery and the Sappey's superior artery

    International Nuclear Information System (INIS)

    Hur, Saebeom; Chung, Jin Wook; Lee, Jae Hwan; Cho, SooBeum; Kim, Minuk; Lee, Myungsu; Kim, Hyo-Cheol; Jae, Hwan Jun; Zhou, Chun Gao

    2017-01-01

    To investigate the prevalence, anatomy and distribution of the hepatic falciform artery (HFA) and Sappey's superior artery (SSA) using C-arm CT hepatic arteriography (C-arm CTHA). From January 2011 to December 2012, 220 patients who underwent C-arm CTHA during initial transarterial treatment for hepatocellular carcinoma were included in this retrospective study. The HFAs and SSAs prevalence and origin were evaluated using axial images of C-arm CTHA. A 5-point scale for HFAs and a 4-point scale for SSAs were used to designate the radiologically conspicuous arteries. The prevalences of the total HFAs and SSAs were 95 % (n=209) and 22 % (n=49), while those of radiologically conspicuous HFAs and SSAs were 62 % (n=137) and 10 % (n=22), respectively. Thirty HFAs (22 % of radiologically conspicuous HFAs and 14 % of the total study population) were distributed in the subcutaneous layer of the anterior abdominal wall, while the majority of SSAs ran through the superior part of the falciform ligament in the left-anterior direction and anastomosed with left inferior phrenic artery. Our study using C-arm CTHA revealed that the prevalence of the HFA is higher than the existing knowledge and proved the existence of the SSA radiologically for the first time. (orig.)

  3. Hepatic vein flow pattern in children: assesment with Doppler sonography

    International Nuclear Information System (INIS)

    Ahmetoglu, Ali; Kosucu, Polat; Arikan, Elif; Dinc, Hasan; Resit Guemele, Halit

    2005-01-01

    Background: Aim of this study is to establish normal hepatic vein flow pattern and effect of age, sex, activity and feeding status on the hepatic flow pattern in normal Turkish children less than 15 years of ages and also to compare our values with the previously reported studies. Method: Hepatic vein flow patterns were evaluated in 150 children (83 male, 67 female) without any cardiac, pulmonary and liver disease by using Doppler sonography. Blood flow patterns were compared with age, sex, activity, and feeding status of the children. Results: Only 44% of the children had triphasic flow pattern in all hepatic veins. Monophasic flow pattern was the most common flow pattern in children less then 1 year of age. Triphasic flow pattern increase after 1 year of age. Although most of the children older than 1 year of age had triphasic flow pattern, there is some variation in the flow patterns of the hepatic veins in the same subject. Triphasic hepatic flow pattern is most commonly seen in the left hepatic vein and least commonly seen in the right hepatic vein. There was no significant difference between male and girl, children who were agitated or calm and fasting or not fasting in respect to triphasic flow pattern. Conclusion: Liver stiffening is not only the reason for abnormal hepatic flow pattern and some other physiologic factors may also lead to mono and/or diphasic flow pattern in the children. Absence of triphasic flow pattern must not be accepted as a liver pathology in children especially younger than 1 year of age

  4. The determination of hepatic blood flow in the rat using Xenon-133

    International Nuclear Information System (INIS)

    Smith, A.; Clarke, M.B.

    1976-01-01

    The measurement of hepatic blood flow in rats undergoing surgical trauma using different anaesthetic techniques has been carried out using the 133 Xe clearance method. Injection into the hepatic artery is followed by monitoring of the liver radioactivity. The complex clearance curves have been analysed using a computer. Details of the surgical technique and the care of the animal while undergoing examination are given. The physiological basis for the clearance curves observed is analysed and a survey of the various parameters which may produce changes in clearance rates is made. Comparison with other investigations show that rat liver blood flows obtained using the 133 Xe clearance method are consistent with others using non-radioactive techniques; because of its simplicity and ease of repetition, the Xenon method is recommended as a way of evaluating drug effects on hepatic blood flow in experimental animals. (author)

  5. Isolated Common Hepatic Artery Branch Thrombosis: Results and Risk Factors

    Directory of Open Access Journals (Sweden)

    Abdoulhossein Davoodabadi

    2016-10-01

    Full Text Available Isolated common hepatic artery branch thrombosis with severe gastric ischemia and duodenojejunal infarction is a rare condition; it usually presents with acute abdomen and may be associated with underlying thrombotic risk factors. We present a 35-year-old man admitted to our hospital with five days history of sudden abdominal pain and deteriorating epigastric pain. He was a driver and had no any past medical history. Explorative laparotomy showed: distal 2/3 gastric, duodenojejunal and papilla vater was sloughed. The stomach subtotal and sloughed duodenum and first 20 cm of jejunum were resected, continuity of the gastrointestinal was preserved with anastomosis of the proximal part of jejunum to gastric stump, pancreatic duct, and CBD repaired to the lateral side of jejunum on the guide of two 18 French feeding tube as an external drain. The patient had a good immediate postoperative recovery. Coagulation checkup after operation revealed isolated Hyperhomocysteinemia.

  6. Role of regional radiofrequency hyperthermia after hepatic artery block in the normal pit liver

    International Nuclear Information System (INIS)

    Luo Jingwei; Xu Guozhen; Xiong Jinghong; Liu Xiaoyun; Wang Weihu; Li Yexiong

    2003-01-01

    Objective: To study the temperature difference, tolerated high temperature, pathological changes between normal and blocked hepatic artery in radiofrequency hyperthermia for pig liver. Methods: Mature pig was used with iodine blocked right hepatic artery. Heat of the whole liver was given for 1 hour by SR-1000 radiofrequency hyperthermia with four thermocouple probes to measure the temperature of the right hepatic artery, right and left normal liver and rectum. Results: Temperature of blocked right liver increased by 10.2 degree C from 39.1 degree C to 49.3 degree C as compared with the left liver of which the temperature rose by 6.8 degree C from 39.7 degree C to 46.5 degree C but the temperature of right hepatic artery and rectum rose only by 3.3 degree C, 3.2 degree C respectively. After sacrificing the pig one week later, on lobe exploration, severe necrosis was observed in the right lobe but the left lobe was normal with a clear demarcation between the two lobes. Conclusions: Hepatic arterial iodine embolization potentiates radiofrequency hyperthermia in the liver. Liver with blocked artery showed conspicuous necrosis but liver with normal un-blocked artery was able to tolerate 46.5 degree C. This provides some evidence for the combination of regional hyperthermia and hepatic artery block in the treatment of advanced liver cancer

  7. The Features of Extrahepatic Collateral Arteries Related to Hepatic Artery Occlusion and Benefits in the Trans arterial Management of Liver Tumors

    International Nuclear Information System (INIS)

    Yang, L.; Zhang, X.M.; Ren, Y.J.; Miao, N.D.; Huang, X.H.; Dong, G.L.

    2013-01-01

    To investigate the extrahepatic collateral arteries related to hepatic artery occlusion (HAO) and to determine its benefits in the trans arterial management of liver tumors. Methods and Findings. Eleven patients (7 hepatocellular carcinomas, 3 liver metastases, and 1 with hemangioma) with HAO confirmed with digital subtraction angiography (DSA) were admitted to our hospital. Of the 11 patients, 7 were men and 4 were women, with an average age of 41.5 ± 15.5 years (range: 29 to 70 years). DSA was performed to evaluate the collateral routes to the liver. In the 11 patients with HAO, DSA showed complete occlusion of the common hepatic artery in 9 patients and the proper hepatic artery (PHA) in 2 patients. Extrahepatic collateral arteries supplying the liver were readily evident. The collateral arteries originated from the superior mesenteric artery (SMA) in 8 patients, from the gastroduodenal artery in 2 patients, and from the left gastric artery (LGA) in 1 patient. Transcatheter treatment was successfully performed via the collateral artery in all patients except the one who had hemangioma. Conclusions. DSA is an effective method for detecting collateral circulation related to HAO and may provide information to guide transcatheter management decisions.

  8. Multidetector-row CT angiography of hepatic artery: comparison with conventional angiography

    International Nuclear Information System (INIS)

    Kim, Jin Woong; Jeong, Yong Yeon; Yoon, Woong; Kim, Jae Kyu; Park, Jin Gyoon; Seo, Jeong Jin; Kang, Heoung Keun

    2003-01-01

    To determine the usefulness of three-dimensional CT angiography using multidetector-row CT (MD-CT) for delineating the arterial anatomy of the liver. Hepatic arterial three-dimensional CT angiography was performed using MDCT (lightspeed Qx/I; GE medical systems, milwaukee, Wis., U.S.A.) in 45 patients with HCC undergoing conventional angiography for transcatheter hepatic arterial chemoembolization. The scanning parameters during the early arterial phase were 2.5 mm slice thickness, 7.5 mm rotation of table speed, and a pitch of 3. Images were obtained by one radiologist using maximum intensity projection from axial CT images obtained during the early arterial phase. Two radiologists blinded to the findings of conventional angiography independently evaluated the hepatic arterial anatomy and the quality of the images obtained. Compared with conventional angiography, reader A correctly evaluated the hepatic arterial anatomy depicted at three-dimensional CT angiography. Reader B's evaluation was correct in 40 of 45 patients. Interobserver agreement was good (kappa value, 0.73), and both readers assessed the quality of three-dimensional CT angiography as excellent. Three-dimensional CT angiography using MDCT was accurate for delineating the arterial anatomy of the liver, and interobserver agreement was good. The modality may provide, prior to conventional angiography, valuable information regrading a patient's hepatic arterial anatomy

  9. Left coronary arterial blood flow: Noninvasive detection by Doppler US

    International Nuclear Information System (INIS)

    Gramiak, R.; Holen, J.; Moss, A.J.; Gutierrez, O.H.; Picone, A.L.; Roe, S.A.

    1986-01-01

    Continuous wave (CW) and pulsed Doppler ultrasound studies with spectral analysis were used to detect the left coronary arterial blood flow in patients who were undergoing routine echocardiography. The pulmonary artery is a stable ultrasonic landmark from which detection of the blood flow can be effected. The left coronary artery can be distinguished by its blood flow toward the cardiac apex and by specific, functional flow features. Flow patterns vary among the left main, circumflex, and anterior descending arteries; patterns also vary with respiration cycles. In the present study, coronary arterial blood flow was detected in 58 of 70 patients (83%). Findings were validated by selectively injecting an agitated saline contrast medium into the left coronary artery and, in another study, by comparing human Doppler phasic flow waveforms with electromagnetic flowmeter recordings obtained in dogs

  10. Resection-Reconstruction of Aberrant Right Hepatic Artery During Whipple Procedure (Pancreaticoduodenectomy).

    Science.gov (United States)

    Sayyed, Raza; Rehman, Iffat; Niazi, Imran Khalid; Yusuf, Muhammed Aasim; Syed, Aamir Ali; V, Faisal

    2016-06-01

    Aberrant hepatic arterial anatomy poses a challenge for the surgeon during Whipple procedure. Intraoperative injury to the aberrant vasculature results in hemorrhagic or ischemic complications involving the liver and biliary tree. We report a case of replaced right hepatic artery arising from the superior mesenteric artery in a patient with periampullary carcinoma of the pancreas, undergoing pancreaticoduodenectomy. The aberrant artery was found to be coursing through the pancreatic parenchyma. This is a rare vascular anomaly. Resection of the arterial segment and end-to-end anastomosis was fashioned. Intrapancreatic course of the replaced right hepatic artery is a rare anomaly and is best managed by preoperative identification on radiology and meticulous intra-operative dissection and preservation. However, for an intrapancreatic course, resection and reconstruction may occasionally be required.

  11. Carbon dioxide hepatic arterial DSA and CT angiography in swine model

    International Nuclear Information System (INIS)

    Tan Huaqiao; Hu Hongjie; Huang Wenxin; Zhang Shizheng; Dong Yonghua; Zhou Dachun

    2005-01-01

    Objective: To evaluate the imaging findings of carbon dioxide hepatic arterial DSA and CT angiography in normal swine. Methods: In general anaesthesia, hepatic arterial DSA was performed with 10 ml iodinated contrast medium (5 ml/s, 10 ml) in 5 normal swine, and then repeated hepatic arterial CO 2 -DSA was performed with a total of 30-50 ml CO 2 injected by manually operated syringe at the velocity of 5-8 ml/s, followed by CO 2 -CT angiography. All the swine were sacrificed after the procedure, the selective hepatic segments were removed, and pathological examination was carried out. The radiological features of hepatic arterial DSA with iodinated contrast medium and CO 2 and CT angiography with CO 2 were analyzed. The ability of showing the arterio-venous shunt was compared. Results: Hepatic arterio-portal shunt was found in the advanced arterial phase of CO 2 -DSA in three of five swine, which was furthermore demonstrated by CO 2 -CT angiography, but iodinated contrast medium DSA showed no arterio-portal shunt in all swine. The gaseous CO 2 in portal vein was absorbed within 1-3 minutes. No CO 2 shunted into the hepatic vein during CO 2 -DSA and CO 2 -CTA. Histology didn't reveal any abnormal changes caused by CO 2 shunt in the swine liver. Conclusion: (1) Hepatic arterial CO 2 -DSA and CO 2 -CTA can reveal arterio-portal shunt that isn't seen with iodinated contrast medium, the gaseous CO 2 in portal vein was absorbed within 1-3 minutes. (2) The gaseous CO 2 can't shunt into hepatic vein when the hepatic artery is perfused with CO 2 in normal swine. (authors)

  12. Efficacy of hepatic arterial infusion chemotherapy in advanced hepatocellular carcinoma

    Science.gov (United States)

    Baek, Yang Hyun; Kim, Kyoung Tae; Lee, Sung Wook; Jeong, Jin Sook; Park, Byeong Ho; Nam, Kyung Jin; Cho, Jin Han; Kim, Young Hoon; Roh, Young Hoon; Lee, Hyung Sik; Choi, Young Min; Han, Sang Young

    2012-01-01

    AIM: To investigate the efficacy of hepatic arterial infusion chemotherapy (HAIC) using floxuridine (FUDR) in patients with advanced hepatocellular carcinoma (HCC) confined to the liver. METHODS: Thirty-four patients who had advanced HCC with unresectability or unsuccessful previous therapy in the absence of extrahepatic metastasis were treated with intra-arterial FUDR chemotherapy at our hospital between March 2005 and May 2008. Among the 34 patients, 9 patients were classified as Child class C, and 18 patients had portal vein tumor thrombus (PVTT). One course of chemotherapy consisted of continuous infusion of FUDR (0.3 mg/kg during day 1-14) and dexamethasone (10 mg on day 1, 4, 7 and 11), and this treatment was repeated every 28 d. RESULTS: Two patients (5.9%) displayed a complete response, and 12 patients (35.3%) had a partial response. The tumor control rate was 61.8%. The median overall survival times were 15.3 mo, 12.4 mo and 4.3 mo for the patients who were classified as Child class A, Child class B and Child class C, respectively (P = 0.0392). The progression-free survival was 12.9 mo, 7.7 mo and 2.6 mo for the patients who were classified as Child class A, Child class B and Child class C, respectively (P = 0.0443). The cumulative survival differed significantly according to the Child-Pugh classification and the presence of PVTT. In addition to hepatic reserve capacity and PVTT, the extent of HCC was an independent factor in determining a poor prognosis. The most common adverse reactions to HAIC were mucositis, diarrhea and peptic ulcer disease, but most of these complications were improved by medical treatment and/or a delay of HAIC. CONCLUSION: The present study demonstrates that intra-arterial FUDR chemotherapy is a safe and effective treatment for advanced HCC that is recalcitrant to other therapeutic modalities, even in patients with advanced cirrhosis. PMID:22807613

  13. Evaluation of variants in hepatic artery anatomy on conventional angiography in patients undergoing transarterial chemoembolization (tace): experience at siut

    International Nuclear Information System (INIS)

    Faiq, S.M.; Jesrani, A.; Jamal, M.; Lalwani, A.

    2017-01-01

    Objective: The purpose of this research is to evaluate common and uncommon variant of hepatic arterial anatomy that usually come across during Hepatic Angiographies. Study Design: Cross sectional study. Methods: This study included 50 patients having history of Hepatocellular Carcinoma from May to October 2015. Hepatic Angiography (Transarterial chemoembolization for management of Hepatoma and identification of classical and variant anatomy of hepatic artery) was evaluated in angiography unit. All procedures were performed on Digital Subtraction Angiography (DSA) machine (Toshiba KXO100 G). Selective DSA of the superior mesenteric artery and celiac trunk is performed initially to evaluate the frequency of normal and variant arterial anatomy and secondly to determine origin and course of tumor-feeding vessels. Evaluation of common and uncommon variants of hepatic arteries was done by using Michel’s classification as reference standard. Results: Age of the patient range from 40 – 80 years, 35 of whom were males. Fifty patients underwent angiographic procedure of viscera. Normal anatomy of hepatic artery was found in twenty eight (56%) cases. In six (12%) cases we found the replaced form of right hepatic artery (RHA) originating from visceral superior mesenteric artery. In five (10%) cases we found the replaced form of left hepatic artery (LHA) originating from left gastric artery (LGA), the combination of both these anomalies in one (2%) patient. Four (8%) cases had the left gastric artery giving rise to accessory left hepatic artery in conjunction with the common hepatic artery of celiac axis giving rise to typical right or left hepatic artery. In another four (8%) cases anatomic variation was noted in form of a dual arterial supply noted as common hepatic artery of celiac axis giving rise to typical left or right hepatic artery in conjunction with superior mesenteric artery giving rise to accessory right hepatic artery. In two (4%) cases superior mesenteric

  14. Prediction of coronary artery bypass graft flow

    International Nuclear Information System (INIS)

    Tamiya, Eiji; Hada, Yoshiyuki; Asano, Ken-ichi; Iio, Masahiro.

    1991-01-01

    To predict the coronary artery bypass graft (CABG) flow based on the time density curve (TDC) obtained from the digital subtraction aortograms (DSA), we developed a pulsatile CABG model (perfusion pressure 60,130 mmHg, pulse rate 53,126/min, cardiac output 3-7 l/min, diameter of the graft 2.1∼6.0 mm). After positioning the regions of interest (ROI), we injected contrast medium(5∼40 ml/sec, 5∼40 ml) into the outlet conduit. Concerning the TDCs, we calculated appearance time (Ta), peak densities (Dp), peak time (Tp), disappearance time (Td), integral of TDC, ΔTp (difference of Tp between two ROI) and ΔTa (difference of Ta between two ROI). Perfusion pressure, graft flow and output curve were similar to those of patients with CABG. Ta, Tp, Td, and ΔTp were affected by both the injection rate and the volume of the contrast medium; while Dp and the TDC integral were only affected by the latter parameter. Under the same conditions of contrast medium injection, the TDC depended strongly on graft flow, diameter of the graft, output and pulse rate. 21.6+0.92π·d 2 /4·Δ1/ΔTp·60 provided the most accurate estimation of CABG flow (r=0.865, p<0.01). We conclude that densitometric analysis of DSA may be useful in the prediction of CABG flow. (author)

  15. Hepatic arterial perfusion increases in the early stage of severe acute pancreatitis patients: Evaluation by perfusion computed tomography

    International Nuclear Information System (INIS)

    Koyasu, Sho; Isoda, Hiroyoshi; Tsuji, Yoshihisa; Yamamoto, Hiroshi; Matsueda, Kazuhiro; Watanabe, Yuji; Chiba, Tsutomu; Togashi, Kaori

    2012-01-01

    Purpose: Although hepatic perfusion abnormalities have been reported in patients with acute pancreatitis, hepatic perfusion with severe acute pancreatitis (SAP) has not been quantitatively evaluated in humans. Therefore, we investigated hepatic perfusion in patients with SAP using perfusion CT. Materials and methods: Hepatic perfusion CT was performed in 67 patients with SAP within 3 days after symptom onset. The patients were diagnosed as having SAP according to the Atlanta criteria. Fifteen cases were established as a control group. Perfusion CT was obtained for 54 s beginning with a bolus injection of 40 ml of contrast agent (600–630 mgI/kg) at a flow rate of 4 ml/s. Perfusion data were analyzed by the dual-input maximum slope method to obtain hepatic arterial perfusion (HAP) and hepatic portal perfusion (HPP). Finally, we compared HAP and HPP in SAP patients with those in the control group, respectively. Results: Average HAP was significantly higher in SAP patients than in the control group (75.1 ± 38.0 vs. 38.2 ± 9.0 ml/min/100 ml; p < 0.001). There was no significant difference in average HPP between SAP patients and the control group (206.7 ± 54.9 vs. 204.4 ± 38.5 ml/min/100 ml; p = 0.92). Conclusion: Using quantitative analysis on perfusion CT, we first demonstrated an increase of HAP in the right hepatic lobe in SAP patients.

  16. Stent grafting of acute hepatic artery bleeding following pancreatic head resection

    International Nuclear Information System (INIS)

    Stoupis, Christoforos; Ludwig, Karin; Triller, Juergen; Inderbitzin, Daniel; Do, Dai-Do

    2007-01-01

    The purpose of this study was to report the potential of hepatic artery stent grafting in cases of acute hemorrhage of the gastroduodenal artery stump following pancreatic head resection. Five consecutive male patients were treated because of acute, life-threatening massive bleeding. Instead of re-operation, emergency angiography, with the potential of endovascular treatment, was performed. Because of bleeding from the hepatic artery, a stent graft (with the over-the-wire or monorail technique) was implanted to control the hemmorhage by preserving patency of the artery. The outcome was evaluated. In all cases, the hepatic artery stent grafting was successfully performed, and the bleeding was immediately stopped. Clinically, immediately after the procedure, there was an obvious improvement in the general patient condition. There were no immediate procedure-related complications. Completion angiography (n=5) demonstrated control of the hemorrhage and patency of the hepatic artery and the stent graft. Although all patients recovered hemodynamically, three individuals died 2 to 10 days after the procedure. The remaining two patients survived, without the need for re-operation. Transluminal stent graft placement in the hepatic artery is a safe and technically feasible solution to control life-threatening bleeding of the gastroduodenal artery stump. (orig.)

  17. Liver Abscess Associated with Hepatic Artery Pseudoaneurysm with Arteriovenous Fistula: Imaging and Interventional Management

    International Nuclear Information System (INIS)

    Kang, M.; Bapuraj, J.R.; Khandelwal, N.; Kochhar, R.; Kalra, N.; Verma, G. R.

    2006-01-01

    Hepatic artery pseudoaneurysm is an infrequently encountered entity that is usually seen secondary to trauma or surgical procedures. The clinical presentation is often due to complications such as massive intrahepatic or intraperitoneal bleeding as a result of rupture of the pseudoaneurysm into the biliary tree or peritoneal cavity, respectively. Hepatic artery pseudoaneurysm, associated with a liver abscess, has very rarely been described in the literature. We present the imaging features of a case of liver abscess associated with a hepatic artery pseudoaneurysm and complicated by rupture and formation of an arteriovenous fistula. The case was successfully managed by percutaneous endovascular embolization. The association between a hepatic artery pseudoaneurysm and a liver abscess must not be overlooked, bearing in mind the potentially fatal associated complications which can be averted or treated by timely intervention

  18. Liver Abscess Associated with Hepatic Artery Pseudoaneurysm with Arteriovenous Fistula: Imaging and Interventional Management

    Energy Technology Data Exchange (ETDEWEB)

    Kang, M.; Bapuraj, J.R.; Khandelwal, N.; Kochhar, R.; Kalra, N.; Verma, G. R. [Postgraduate Inst. of Medical Education and Research, Chandigarh (India). Depts. of Radiodiagnosis and General Surgery

    2006-03-15

    Hepatic artery pseudoaneurysm is an infrequently encountered entity that is usually seen secondary to trauma or surgical procedures. The clinical presentation is often due to complications such as massive intrahepatic or intraperitoneal bleeding as a result of rupture of the pseudoaneurysm into the biliary tree or peritoneal cavity, respectively. Hepatic artery pseudoaneurysm, associated with a liver abscess, has very rarely been described in the literature. We present the imaging features of a case of liver abscess associated with a hepatic artery pseudoaneurysm and complicated by rupture and formation of an arteriovenous fistula. The case was successfully managed by percutaneous endovascular embolization. The association between a hepatic artery pseudoaneurysm and a liver abscess must not be overlooked, bearing in mind the potentially fatal associated complications which can be averted or treated by timely intervention.

  19. Hepatic encephalopathy is associated with decreased cerebral oxygen metabolism and blood flow, not increased ammonia uptake

    DEFF Research Database (Denmark)

    Dam, Gitte; Keiding, Susanne; Munk, Ole Lajord

    2013-01-01

    Studies have shown decreased cerebral oxygen metabolism (CMRO(2)) and blood flow (CBF) in patients with cirrhosis with hepatic encephalopathy (HE). It remains unclear, however, whether these disturbances are associated with HE or with cirrhosis itself and how they may relate to arterial blood...... associated with HE rather than the liver disease as such. The changes in CMRO(2) and CBF could not be linked to blood ammonia concentration or CMRA....

  20. Modified sleeve anastomosis for reconstruction of the hepatic artery in rat liver transplantation.

    Science.gov (United States)

    Li, Jun; Dahmen, Uta; Dirsch, Olaf; Shen, Kai; Gu, Yanli; Broelsch, Christoph Erich

    2002-01-01

    End-to-end sleeve anastomosis between a donor common hepatic artery and a recipient proper hepatic artery was proven to be the most physiological and simple method for hepatic rearterialization in rat liver transplantation. Current technical variants of the sleeve technique, however, are hampered by the high rate of bleeding from the anastomotic site. This report deals with a technical modification which inhibits postoperative bleeding efficiently. The procedure consisted of a guiding suture, as previously described in other technical variants, and a modified fixing suture. Instead of using a single stitch to fix the feeding vessel with the receiving vessel, a running suture between the edge of the donor common hepatic artery and the adventitia of the recipient proper hepatic artery was performed to avoid a possible backflow. The patency rate of 91% was as high as reported by others using a sleeve technique, which was also reflected in the histomorphological picture, being indistinguishable from normal liver histology. This technical modification simplified the procedure of reconstructing the hepatic artery and could contribute to a wider use of the arterialized liver transplantation model in rats. Copyright 2002 Wiley-Liss, Inc.

  1. Temporary balloon occlusion of the common hepatic artery for administration of yttrium-90 resin microspheres in a patient with patent hepatoenteric collaterals.

    Science.gov (United States)

    Mahvash, Armeen; Zaer, Navid; Shaw, Colette; Chasen, Beth; Avritscher, Rony; Murthy, Ravi

    2012-02-01

    The most common serious complication of yttrium-90 ((90)Y) therapy is gastrointestinal ulceration caused by extrahepatic microsphere dispersion. The authors describe the use of a balloon catheter for temporary occlusion of the common hepatic artery to reverse hepatoenteric flow for lobar administration of resin microspheres when coil embolization of a retroportal artery was impossible. At 9 months after treatment, the patient had no gastrointestinal side effects and showed a partial response. Copyright © 2012 SIR. Published by Elsevier Inc. All rights reserved.

  2. Prehepatocholedochal proper hepatic artery. Rare anatomical variant. Surgical considerations. Case report.

    Science.gov (United States)

    Ardeleanu, V; Chicoş, S; Tutunaru, D; Georgescu, C

    2014-01-01

    In classical anatomic variants, the proper hepatic artery (PHA)continues the common hepatic artery (CHA) after the gastroduodenal artery (GDA) detaches itself and divides into the right hepatic artery (RHA) and left hepatic artery (LHA), the proper hepatic artery being located to the left of the hepatocholedochal duct (HCD). This paper presents an abnormal positioning of the PHA placed before the HCD with an increased diameter of about 5-7 mm, which could be confused with the HCD. We present the case of a 57 year-old woman diagnosed with acute lithiasic cholecystitis, associated with hypersplenism and hypertension. The literature mentions manifold anatomical variants of arterial liver vascularization,including PHA. For this reason, this paper presents an overview of similar cases that can be found in medical literature. The aforementioned case is a rare topographic anatomy for the PHA that can easily pass for HCD especially during celioscopy, therefore it is crucial for this to be acknowledged by all surgeons. Celsius.

  3. Impact of Multislice CT Angiography on Planning of Radiological Catheter Placement for Hepatic Arterial Infusion Chemotherapy

    International Nuclear Information System (INIS)

    Sone, Miyuki; Kato, Kenichi; Hirose, Atsuo; Nakasato, Tatsuhiko; Tomabechi, Makiko; Ehara, Shigeru; Hanari, Takao

    2008-01-01

    The objective of this study was to assess prospectively the role of multislice CT angiography (MSCTA) on planning of radiological catheter placement for hepatic arterial infusion chemotherapy (HAIC). Forty-six patients with malignant liver tumors planned for HAIC were included. In each patient, both MSCTA and intra-arterial digital subtraction angiography (DSA) were performed, except one patient who did not undergo DSA. Comparison of MSCTA and DSA images was performed for the remaining 45 patients. Detectability of anatomical variants of the hepatic artery, course of the celiac trunk, visualization scores of arterial branches and interobserver agreement, presence of arterial stenosis, and technical outcome were evaluated. Anatomical variations of the hepatic artery were detected in 19 of 45 patients (42%) on both modalities. The course of the celiac trunk was different in 12 patients. The visualization scores of celiac arterial branches on MSCTA/DSA were 3.0 ± 0/2.9 ± 0.2 in the celiac trunk, 3.0 ± 0/2.9 ± 0.3 in the common hepatic artery, 2.9 ± 0.2/2.9 ± 0.3 in the proper hepatic artery, 2.9 ± 0.3/2.9 ± 0.4 in the right hepatic artery, 2.8 ± 0.4/2.9 ± 0.4 in the left hepatic artery, 2.9 ± 0.2/2.9 ± 0.3 in the gastroduodenal artery, 2.1 ± 0.8/2.2 ± 0.9 in the right gastric artery, and 2.7 ± 0.8/2.6 ± 0.8 in the left gastric artery. No statistically significant differences exist between the two modalities. Interobserver agreement for MSCTA was equivalent to that for DSA. Two patients showed stenosis of the celiac trunk on both modalities. Based on these imaging findings, technical success was accomplished in all patients. In conclusion, MSCTA is accurate in assessing arterial anatomy and abnormalities. MSCTA can provide adequate information for planning of radiological catheter placement for HAIC

  4. Prospect of drug distribution to hepatic cancer in intra-arterial infusion chemotherapy. Examination by infusion of sup(81m)Kr and /sup 133/Xe via catheter into hepatic artery

    Energy Technology Data Exchange (ETDEWEB)

    Sasaki, Y; Imaoka, S; Matsui, Y; Ishikawa, O; Taniguchi, K [Osaka Prefectural Center for Adult Diseases (Japan)

    1982-04-01

    Cannulation into the hepatic artery under laparotomy was performed to nine patients of non-resectable hepatic cancer (eight of hepatocellular carcinoma, and one of cholangiocellular carcinoma), and injected sup(81m)Kr (Tsub(1/2) = 13 sec.) continuously via catheter into hepatic artery as the model of continuous intra-arterial infusion chemotherapy, and /sup 133/Xe (Tsub(1/2) = 5.3 days) by bolus injection as the model of one-shot ones. During and immediately after injection, sequential scintigrams were carried out and simultaneously images were acquired on a medical computer. Higher radioactivities of both sup(81m)Kr and /sup 133/Xe were observed in tumor than non-tumor region in seven of eight patients of hepatocellular carcinoma. The radioactive ratio of tumor to non-tumor (T/C ratio) was over 1.0 in these cases. This result indicated that there was more arterial blood flow in tumor than non-tumor region, and it could be expected to obtain higher distribution of drugs in tumor on both continuous and one-shot infusion chemotherapy. The pattern of distribution of sup(81m)Kr changed according to positions of patients, and in some cases T/C ratio was higher in other positions than supine position. The most effective position of the intra-arterial infusion chemotherapy could be selected by this method. This technique seems to make it possible to prospect the arrival of drugs to the tumor and presume the effectiveness of intra-arterial infusion chemotherapy.

  5. The establishment of implanted VX2 liver tumor model in rabbits and discussion on superselective left hepatic arterial catheterization with micro-catheter technique via femoral artery

    International Nuclear Information System (INIS)

    Jiang Xiongying; Luo Rongguang; Huang Jinhua; Miao Bijian; Wang Yan

    2011-01-01

    Objective: To establish the implanted VX2 liver tumor model in rabbits and to discuss the feasibility and technical features of superselective left hepatic arterial catheterization by using micro-catheter through the femoral artery catheter sheath. Methods: Forty New Zealand white rabbits were inoculated with fragments of VX2 tumor into the medial left lobe of liver by using a 16G lumbar puncture needle through laparotomy route. Two weeks later, all the rabbits were proved to be successfully inoculated with liver neoplasm on CT scanning. Then, the catheter sheath was inserted into one of the femoral arteries, which was followed by celiac artery angiography and left hepatic artery catheterization with a micro-catheter under DSA guidance in order to evaluate the main branches of celiac artery and the imaging manifestations of VX2 liver tumor. After that, some scheduled interventional experiments were carried out. Results: Imaging examination and histopathologic study showed that the successful rate of implanted rabbit VX2 liver tumor was 100% (40/40). And the successful rate of the catheter sheath inserted to femoral artery was 97.5% (39/40). The successful rate of celiac artery, gastro-hepatic artery, common hepatic artery, proper hepatic artery and left hepatic artery catheterizations was 100% (39/39), 100% (39/39), 100% (39/39), 94.9% (37/39) and 71.2% (28/39) respectively. Conclusion: To implant tumor tissue mass through laparotomy is a stable and reliable method to establish rabbit VX2 liver tumor model. The insertion of micro-catheter through rabbit femoral catheter sheath approach is a convenient and simple technique to be carried out for the left hepatic artery catheterization and it can efficiently solve the technical difficulties when performing the interventional treatment of the rabbit VX2 hepatic tumor via left hepatic artery approach. (authors)

  6. Utility of Amplatzer Vascular Plug with Preoperative Common Hepatic Artery Embolization for Distal Pancreatectomy with En Bloc Celiac Axis Resection

    International Nuclear Information System (INIS)

    Toguchi, Masafumi; Tsurusaki, Masakatsu; Numoto, Isao; Hidaka, Syojiro; Yamakawa, Miho; Asato, Nobuyuki; Im, SungWoon; Yagyu, Yukinobu; Matsuki, Mitsuru; Takeyama, Yoshifumi; Murakami, Takamichi

    2017-01-01

    PurposeTo evaluate the feasibility and safety of the Amplatzer vascular plug (AVP) for preoperative common hepatic embolization (CHA) before distal pancreatectomy with en bloc celiac axis resection (DP-CAR) to redistribute blood flow to the stomach and liver via the superior mesenteric artery (SMA).Materials and MethodsFour patients (3 males, 1 female; median age 69 years) with locally advanced pancreatic body cancer underwent preoperative CHA embolization with AVP. After embolization, SMA arteriography was performed to confirm the alteration of blood flow from the SMA to the proper hepatic artery.ResultsIn three of four patients, technical successes were achieved with sufficient margin from the origin of gastroduodenal artery. In one patient, the margin was less than 5 mm, although surgery was successfully performed without any problem. Eventually, all patients underwent the DP-CAR without arterial reconstruction or liver ischemia.ConclusionsAVP application is feasible and safe as an embolic procedure for preoperative CHA embolization of DP-CAR.

  7. Utility of Amplatzer Vascular Plug with Preoperative Common Hepatic Artery Embolization for Distal Pancreatectomy with En Bloc Celiac Axis Resection

    Energy Technology Data Exchange (ETDEWEB)

    Toguchi, Masafumi, E-mail: e024163@yahoo.co.jp; Tsurusaki, Masakatsu; Numoto, Isao; Hidaka, Syojiro; Yamakawa, Miho [Kindai University, Department of Radiology, Faculty of Medicine (Japan); Asato, Nobuyuki [Kindai University, Department of Radiology, Faculty of Medicine, Nara Hospital (Japan); Im, SungWoon; Yagyu, Yukinobu; Matsuki, Mitsuru [Kindai University, Department of Radiology, Faculty of Medicine (Japan); Takeyama, Yoshifumi [Kindai University, Department of Surgery, Faculty of Medicine (Japan); Murakami, Takamichi [Kindai University, Department of Radiology, Faculty of Medicine (Japan)

    2017-03-15

    PurposeTo evaluate the feasibility and safety of the Amplatzer vascular plug (AVP) for preoperative common hepatic embolization (CHA) before distal pancreatectomy with en bloc celiac axis resection (DP-CAR) to redistribute blood flow to the stomach and liver via the superior mesenteric artery (SMA).Materials and MethodsFour patients (3 males, 1 female; median age 69 years) with locally advanced pancreatic body cancer underwent preoperative CHA embolization with AVP. After embolization, SMA arteriography was performed to confirm the alteration of blood flow from the SMA to the proper hepatic artery.ResultsIn three of four patients, technical successes were achieved with sufficient margin from the origin of gastroduodenal artery. In one patient, the margin was less than 5 mm, although surgery was successfully performed without any problem. Eventually, all patients underwent the DP-CAR without arterial reconstruction or liver ischemia.ConclusionsAVP application is feasible and safe as an embolic procedure for preoperative CHA embolization of DP-CAR.

  8. Immersed boundary simulation of flow through arterial junctions

    Indian Academy of Sciences (India)

    Dwaipayan Sarkar

    haemodynamic activities in regions like carotid arteries, encephalic regions and ... immersed boundary method (IBM), has gained attention in the last few years .... the flow from left inlet and the flow is subsequently divided among the two ...

  9. Flow analysis of the ophthalmic artery

    Energy Technology Data Exchange (ETDEWEB)

    Harada, Kuniaki; Hashimoto, Masato; Bandoh, Michio; Odawara, Yoshihiro; Kamagata, Masaki; Shirase, Ryuji [Sapporo Medical Univ. (Japan). Hospital

    2003-02-01

    The purpose of this study was to analyze the hemodynamics of ophthalmic artery flow using phase contrast MR angiography (PC-MRA). A total of 14 eyes from 10 normal volunteers and a patient with normal tension glaucoma (NTG) were analyzed. The optimal conditions were time repetition (TR)/echo time (TE)/flip angle (FA)/nex=40 ms/minimum/90 deg/2, field of view (FOV)=6 cm, matrix size=256 x 256. The resistive index (RI) and pulsatillity index (PI) values were significantly raised in the patient with NTG when compared to the control group. We therefore believe that PC-MRA may be a useful clinical tool for the assessment of the mechanism of NTG. (author)

  10. Forearm arterial anatomy and flow characteristics: a prospective observational study.

    Science.gov (United States)

    Pancholy, Samir B; Heck, Laura A; Patel, Tejas

    2015-04-01

    Morphometric data on Caucasian radial and ulnar arteries are limited, with no data on flow interdependence in the forearm arterial circuit. A total of 250 upper extremities in 125 patients were evaluated. Ultrasonography was performed and radial and ulnar artery lumen diameters were measured. Ulnar artery (UA) was compressed at the level of the wrist, and flow parameters in radial artery (RA) were recorded using duplex Doppler ultrasound. Radial and ulnar artery diameters were comparable at the level of the distal forearm (RA = 2.03 ± 0.28 mm, UA = 2.07 ± 0.27 mm; P=.14). There was no significant difference in radial or ulnar artery diameter between the dominant upper extremity and the non-dominant upper extremity. Upon compression of the ulnar artery, radial artery velocity-time integral (VTI) increased from 8.4 ± 3.8 cm to 12.8 ± 5.5 cm, which was statistically significant (Pforearm is comparable to UA. RA-VTI and likely flow significantly increase by compression of the UA. The smaller the radial artery, the larger the increase in radial artery flow with ulnar compression.

  11. Dynamic exercise enhances regional cerebral artery mean flow velocity

    DEFF Research Database (Denmark)

    Linkis, P; Jørgensen, L G; Olesen, H L

    1995-01-01

    Dynamic exercise enhances regional cerebral artery mean flow velocity. J. Appl. Physiol. 78(1): 12-16, 1995.--Anterior (ACA) and middle (MCA) cerebral artery mean flow velocities (Vmean) and pulsatility indexes were determined using transcranial Doppler in 14 subjects during dynamic exercise afte...

  12. Microcatheter with a ball tip for hepatic embolization and intra-arterial chemotherapy

    International Nuclear Information System (INIS)

    Hori, S.; Matsushita, M.; Narumi, Y.; Fujita, M.; Tomoda, K.; Marukawa, T.; Kuroda, C.; Kozuka, T.

    1989-01-01

    A microcatheter used mainly for cranial arterial embolization and chemotherapy was employed for hepatic arterial embolization. The tip of the microcatheter is inflated like a small balloon which then acts as a calibrated-leak balloon. A coaxial system employing a conventional catheter for abdominal angiography combined with a propulsion chamber was used. Successful chemotherapy and embolization by Lipiodol and Spongel was carried out even in cases in whom it had been considered impossible to insert a catheter into the desired arteries. (orig.)

  13. [Ultrasonographic study of blood flow in the renal arteries of patients with arterial hypertension].

    Science.gov (United States)

    Makarenko, E S; Dombrovskiĭ, V I; Nelasov, N Iu

    2012-01-01

    Vascular duplex ultrasound duplex with simultaneous ECG registration was made to estimate the quantitative and time parameters of blood flow in the renal arteries with grade 1-2 arterial hypertension. There were increases in vascular resistance indices and acceleration phase index and a reduction in systolic phase index. There were correlations of the time parameters of blood flow in the renal arteries with age and lipidogram values.

  14. Hepatic arterial supply in 1297 CT-angiographies; Die arterielle Leberversorgung in 1297 CT-Angiografien

    Energy Technology Data Exchange (ETDEWEB)

    Loeschner, C.; Kausche, S.; Teichgraeber, U. [Jena University Hospital, Jena (Germany). Dept. of Radiology; Nagel, S.N. [Charite Universitaetsmedizin Berlin (Germany). Dept. of Radiology

    2015-04-15

    Analysis, evaluation and classification of hepatic arterial supply variants and determination of their frequency distribution in CT-angiographies. CT-angiographies of 1,568 patients were evaluated retrospectively for the period between January 1, 2010 and August 30, 2012. The hepatic arterial anatomy was assessed and categorized according to Michels's classification. So far unclassified variants were considered separately. Results: CT-angiographies of 1297 patients were included in the study. Type I according to Michels was seen in 937 cases (72.2%), followed by type V in 114 patients (8.8%) and type III in 83 patients (6.4%). Type X could not be found in any of the patients. Not yet classified variants were discovered in 26 patients. The most frequent variant in this connection was a right hepatic artery originating from the superior mesenteric artery with the left hepatic artery originating from the left gastric artery (n=10). Michels's classification could be largely confirmed on the basis of a radiologically examined patient population. Not yet classified variants were categorized into subgroups of the existing classification.

  15. Measurement of regional hepatic blood flow by scintiphotosplenoportography

    Energy Technology Data Exchange (ETDEWEB)

    Kashiwagi, T; Kimura, K; Kamada, T; Abe, H [Osaka Univ. (Japan). Dept. of Radiology and Nuclear Medicine

    1978-08-01

    A new technique for estimating regional hepatic blood flow using the inert gas washout technique and scintillation camera following injection of /sup 133/Xe into the spleen is presented. This technique is easily, rapidly and repeatedly performed and permits the measurement of nutrient hepatic tissue blood flow. Measurement of regional hepatic blood flow in right and/or left lobes was performed in 28 patients. In all but one patient the right lobar flow value was equal to or greater than the left one. The right lobar flow was 86.20 +- 12.83 ml/100 gm/min in 3 patients without liver disease, 75.12 +- 14.54 ml/100 gm/min in 12 with chronic hepatitis and 51.24 +- 17.13 ml/100 gm/min in 11 with liver cirrhosis. This result suggests that hepatic tissue blood flow is significantly decreased in patients with liver cirrhosis. Scintillation camera images of initial xenon distribution in combination with monitor of washout curves over the liver also provide more information on the presence of extra- and intrahepatic shunts. Therefore, this technique appears to be clinically useful in evaluation of hemodynamic phenomena associated with liver diseases.

  16. [Clinical application of combined hepatic artery resection and reconstruction in surgical treatment for hilar cholangiocarcinoma].

    Science.gov (United States)

    Dai, H S; Bie, P; Wang, S G; He, Y; Li, D J; Tian, F; Zhao, X; Chen, Z Y

    2018-01-01

    Objective: To clarify whether the surgical treatment for hilar cholangiocarcinoma combined with artery reconstruction is optimistic to the patients with hilar cholangiocarcinoma with hepatic artery invasion. Methods: There were 384 patients who received treatment in the First Affiliated Hospital to Army Medical University from January 2008 to January 2016 analyzed retrospectively. There were 27 patients underwent palliative operation, 245 patients underwent radical operation, radical resection account for 63.8%. Patients were divided into four groups according to different operation method: routine radical resection group( n =174), portal vein reconstruction group ( n =47), hepatic artery reconstruction group ( n =24), palliative group( n =27). General information of patients who underwent radical operation treatment was analyzed by chi-square test and analysis of variance. The period of operation time, blood loss, the length of hospital stay and hospitalization expenses of the radical operation patients were analyzed by one-way ANOVA. Comparison among groups was analyzed by LSD- t test. Results: The follow-up ended up in June first, 2016. Each of patients followed for 6 to 60 months, the median follow-up period was 24 months. 1-, 3-, and 5-year survival rates were 81.3%, 44.9% and 13.5% of routine radical operation group, and were 83.0%, 44.7% and 15.1% of portal vein reconstruction group, and were 70.8%, 27.7% and 6.9% of hepatic artery reconstruction group, respectively. And 1-, 3-, and 5-year survival rates of hepatic artery reconstruction group was lower than routine radical group and portal vein reconstruction group significantly ( P 0.05). The data shows that the ratio of lymphatic metastasis in hepatic artery reconstruction group (70.8%) is much higher than them in routine radical operation group (20.1%) and portal vein reconstruction group (19.1%) significantly ( P hilar cholangiocarcinoma. Cox regression analysis indicate that hepatic artery resection and

  17. Nursing care of patients receiving interventional therapy for hepatic artery stenosis after liver transplantation

    International Nuclear Information System (INIS)

    Wei Lin; Liu Shiguang

    2009-01-01

    Objective: To discuss the perioperative nursing care of patients who is going to receive interventional therapy for hepatic artery stenosis after liver transplantation and to provide useful reference for reducing surgery-related complication and for improving the prognosis of patients. Methods: Based on the patient's condition and operative requirement,we provided effective nursing care for 20 patients who were admitted to receive the interventional therapy for hepatic artery stenosis after liver transplantation. The nursing care included preoperative preparation,postoperative nursing and medical guidance at the time of discharge. Results: Interventional therapy was successfully performed in all 20 cases, and no hemorrhagic tendency or acute thrombosis occurred. Marked symptomatic improvement was obtained in all patients. Conclusion: The interventional therapy is an effective treatment for hepatic artery stenosis after liver transplantation. Intensive perioperative nursing care can well prevent the occurrence of surgery-related complications and can surely improve the therapeutic results. (authors)

  18. [Prognostic Doppler ultrasound examination of fetal arteries blood flow].

    Science.gov (United States)

    Sieroszewski, Piotr; Sabatowska, Małgorzata; Karowicz-Bilińska, Agata; Suzin, Jacek

    2002-08-01

    Early detection of fetal risk is one of the main issues in today obstetrics. Ultrasound diagnostics plays a significant role, as the introduction of Doppler imaging method in the evaluation of blood flow has enabled non-invasive assessment of uteroplacental circulation. Therefore, we have analysed foetal three arteries: umbilical artery, middle cerebral artery and renal artery after determining the normal range for the analysed parameters. 1. Comparison of the obtained blood flow indices (S/D, RI, PI) in the umbilical artery, middle cerebral artery and renal artery of foetuses from normal and complicated full-term pregnancies. 2. Determination of indices: umbilical-cerebral and renal-cerebral in normal and pathological pregnancy. 3. Evaluation of feasibility of the analysed flow parameters for the detection of intrauterine foetal hypoxia. We have examined 151 women, who were divided into control group--101 pregnant women with normal pregnancy and study group--50 pregnant women with complicated pregnancy. All pregnant women underwent ultrasound examination using the Hitachi EUB 515 C (Japan) scanner with 3.5 MHz convex probe, connected to the colour pulsed Doppler. The study consisted of the biometric measurements and evaluation of the spectrum of blood flow in the umbilical artery, middle cerebral artery and renal artery. We have determined following indices: a) systolic-diastolic ratio S/D, resistance index RI, pulsatility index PI, b) umbilical-cerebral ratio P/M. (PI ua/PI mca), renal--cerebral ratio N/M (PI ra/PI mca). Statistically significant difference was found between the study and control groups for all the flow indices assessed (S/D, RI, PI) for the middle cerebral artery, for the indices P/M and N/M. (p < 0.001) and pulsatility index in the renal artery (p < 0.01). Similar, although slightly smaller difference (p < 0.05) was seen for the values of flow parameters in the umbilical artery. 1) Evaluation of blood flow in the middle cerebral artery, and in

  19. Quantification of hepatic flow distribution using particle tracking for patient specific virtual Fontan surgery

    Science.gov (United States)

    Yang, Weiguang; Vignon-Clementel, Irene; Troianowski, Guillaume; Shadden, Shawn; Mohhan Reddy, V.; Feinstein, Jeffrey; Marsden, Alison

    2010-11-01

    The Fontan surgery is the third and final stage in a palliative series to treat children with single ventricle heart defects. In the extracardiac Fontan procedure, the inferior vena cava (IVC) is connected to the pulmonary arteries via a tube-shaped Gore-tex graft. Clinical observations have shown that the absence of a hepatic factor, carried in the IVC flow, can cause pulmonary arteriovenous malformations. Although it is clear that hepatic flow distribution is an important determinant of Fontan performance, few studies have quantified its relation to Fontan design. In this study, we virtually implanted three types of grafts (T-junction, offset and Y-graft) into 5 patient specific models of the Glenn (stage 2) anatomy. We then performed 3D time-dependent simulations and systematically compared the IVC flow distribution, energy loss, and pressure levels in different surgical designs. A robustness test is performed to evaluate the sensitivity of hepatic distribution to pulmonary flow split. Results show that the Y-graft design effectively improves the IVC flow distribution, compared to traditional designs and that surgical designs could be customized on a patient-by-patient basis.

  20. Hepatic artery stent-grafts for the emergency treatment of acute bleeding

    Energy Technology Data Exchange (ETDEWEB)

    Bellemann, Nadine, E-mail: nadine.bellemann@med.uni-heidelberg.de [Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg, INF 110, 69120 Heidelberg (Germany); Sommer, Christof-Matthias; Mokry, Theresa; Kortes, Nikolas; Gnutzmann, Daniel; Gockner, Theresa; Schmitz, Anne [Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg, INF 110, 69120 Heidelberg (Germany); Weitz, Jürgen [Department of Surgery, University Hospital Heidelberg, INF 110, 69120 Heidelberg (Germany); Department for Visceral, Thoracic and Vascular Surgery at the University Hospital, Technical University Dresden (Germany); Kauczor, Hans-Ulrich; Radeleff, Boris; Stampfl, Ulrike [Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg, INF 110, 69120 Heidelberg (Germany)

    2014-10-15

    Highlights: • We report our experiences with stent-grafts for the treatment of acute hemorrhage from the hepatic artery or the stump of the gastroduodenal artery. • The technical success of stent-graft implantation was 88%. • The bleeding ceased immediately after stent-graft implantation in 88%. • The complication rate was 21%. - Abstract: Purpose: We evaluated the technical success and clinical efficacy of stent-graft implantation for the emergency management of acute hepatic artery bleeding. Methods: Between January 2010 and July 2013, 24 patients with hemorrhage from the hepatic artery were scheduled for emergency implantation of balloon expandable stent-grafts. The primary study endpoints were technical and clinical success, which were defined as successful stent-graft implantation with sealing of the bleeding site at the end of the procedure, and cessation of clinical signs of hemorrhage. The secondary study endpoints were complications during the procedure or at follow-up and 30-day mortality rate. Results: In 23 patients, hemorrhage occurred after surgery, and in one patient hemorrhage occurred after trauma. Eight patients had sentinel bleeding. In most patients (n = 16), one stent-graft was implanted. In six patients, two overlapping stent-grafts were implanted. The stent-grafts had a target diameter between 4 mm and 7 mm. Overall technical success was 88%. The bleeding ceased after stent-graft implantation in 21 patients (88%). The mean follow-up was 137 ± 383 days. In two patients, re-bleeding from the hepatic artery occurred during follow-up after 4 and 29 days, respectively, which could be successfully treated by endovascular therapy. The complication rate was 21% (minor complication rate 4%, major complication rate 17%). The 30-day mortality rate was 21%. Conclusions: Implantation of stent-grafts in the hepatic artery is an effective emergency therapy and has a good technical success rate for patients with acute arterial hemorrhage.

  1. Use of a Stent Graft for Bleeding Hepatic Artery Pseudoaneurysm Following Pancreaticoduodenectomy

    Directory of Open Access Journals (Sweden)

    Leoncio L. Kaw, Jr

    2006-10-01

    Full Text Available Although uncommon, bleeding following pancreaticoduodenectomy is associated with high mortality. Management generally includes surgical reexploration or, alternatively, transarterial embolization. We report the case of a 62-year-old man who presented with massive upper gastrointestinal bleeding 3 weeks after pancreaticoduodenectomy. Selective coeliac angiography revealed a large pseudoaneurysm involving the proper hepatic artery. This was treated successfully with a stent graft. There was no recurrence of bleeding at the 6-month follow-up. To our knowledge, this is the first report of stent graft repair of bleeding hepatic artery pseudoaneurysm following pancreaticoduodenectomy.

  2. Clinical observation on coil embolization in treatment of hepatic arterial pseudoaneurysm

    International Nuclear Information System (INIS)

    Chen Yaoting; Xu Linfeng; Jiang Rongjian; Zhou Jingxing; Luo Jianghong; Tang Qiyun; Hu Renmei

    2007-01-01

    Objective: To discuss the method, mid-long term clinical therapeutic effect and safety of coil embolization in treating patients with hepatic arterial pseudoaneurysm (HAPA). Methods: Seven patients with repeatedly massive hemorrhage of gastrointestinal tract were undertaken DSA of celiac arteries and hepatic arteries and embolization of the feeding artery by coils or microcoils after correct diagnosis. All cases underwent follow-up from 6 to 60 months(mean 38). Results: The blood loss before angiography was ranged from 1200 to 4 000 (mean 2 385) ml. There were 3 cases with normal hepatic function and 4 with hepatic dysfunction including ALT increase in 2 and obstructive jaundice in another. Digital substraction angiography (DSA) clearly showed the location, shape and feeding arteries of HAPA. There were 2 types of HAPA namely intrahepatic (n=3)and extrahepatic (n=4), adding one case with arteriovenous fistula (AVF). Embolization was successful in all cases by coils (n=13) or microcoils (n=12). No recurrence and any definite clinical complication occurred during follow-up. Conclusion: Coil embolization in treating HAPA is safe and effective with mid-long term positive clinical therapeutic efficiency without severe complications. (authors)

  3. Determinants of systemic zero-flow arterial pressure.

    Science.gov (United States)

    Brunner, M J; Greene, A S; Sagawa, K; Shoukas, A A

    1983-09-01

    Thirteen pentobarbital-anesthetized dogs whose carotid sinuses were isolated and perfused at a constant pressure were placed on total cardiac bypass. With systemic venous pressure held at 0 mmHg (condition 1), arterial inflow was stopped for 20 s at intrasinus pressures of 50, 125, and 200 mmHg. Zero-flow arterial pressures under condition 1 were 16.2 +/- 1.3 (SE), 13.8 +/- 1.1, and 12.5 +/- 0.8 mmHg, respectively. In condition 2, the venous outflow tube was clamped at the instant of stopping the inflow, causing venous pressure to rise. The zero-flow arterial pressures were 19.7 +/- 1.3, 18.5 +/- 1.4, and 16.4 +/- 1.2 mmHg for intrasinus pressures of 50, 125, and 200 mmHg, respectively. At all levels of intrasinus pressure, the zero-flow arterial pressure in condition 2 was higher (P less than 0.005) than in condition 1. In seven dogs, at an intrasinus pressure of 125 mmHg, epinephrine increased the zero-flow arterial pressure by 3.0 mmHg, whereas hexamethonium and papaverine decreased the zero-flow arterial pressure by 2 mmHg. Reductions in the hematocrit from 52 to 11% resulted in statistically significant changes (P less than 0.01) in zero-flow arterial pressures. Thus zero-flow arterial pressure was found to be affected by changes in venous pressure, hematocrit, and vasomotor tone. The evidence does not support the literally interpreted concept of the vascular waterfall as the model for the finite arteriovenous pressure difference at zero flow.

  4. Vasopressin and nitroglycerin decrease portal and hepatic venous pressure and hepato-splanchnic blood flow.

    Science.gov (United States)

    Wisén, E; Svennerholm, K; Bown, L S; Houltz, E; Rizell, M; Lundin, S; Ricksten, S-E

    2018-03-26

    Various methods are used to reduce venous blood pressure in the hepato-splanchnic circulation, and hence minimise blood loss during liver surgery. Previous studies show that combination of vasopressin and nitroglycerin reduces portal pressure and flow in patients with portal hypertension, and in this study we investigated this combination in patients with normal portal pressure. In all, 13 patients were studied. Measurements were made twice to confirm baseline (C1 and BL), during vasopressin infusion 4.8 U/h (V), and during vasopressin infusion combined with nitroglycerin infusion (V + N). Portal venous pressure (PVP), hepatic venous pressure (HVP), central haemodynamics and arterial and venous blood gases were obtained at each measuring point, and portal (splanchnic) and hepato-splanchnic blood flow changes were calculated. Vasopressin alone did not affect PVP, whereas HVP increased slightly. In combination with nitroglycerin, PVP decreased from 10.1 ± 1.6 to 8.9 ± 1.3 mmHg (P HVP decreased from 7.9 ± 1.9 to 6.2 ± 1.3 mmHg (P = 0.001). Vasopressin reduced portal blood flow by 47 ± 19% and hepatic venous flow by 11 ± 18%, respectively. Addition of nitroglycerin further reduced portal- and hepatic flow by 55 ± 13% and 30 ± 13%, respectively. Vasopressin alone had minor effects on central haemodynamics, whereas addition of nitroglycerin reduced cardiac index (3.2 ± 0.7 to 2.7 ± 0.5; P < 0.0001). The arterial-portal vein lactate gradient was unaffected. The combination of vasopressin and nitroglycerin decreases portal pressure and hepato-splanchnic blood flow, and could be a potential treatment to reduce bleeding in liver resection surgery. © 2018 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  5. Studies on the hepatic hemodynamics of the patients with fatty liver by hepatic blood flow mapping

    International Nuclear Information System (INIS)

    Kubo, Shuichi; Okajima, Tugio; Yamazaki, Yasurou

    1991-01-01

    To investigate intrahepatic hemodynamics of the patients with fatty liver, the time to reach maximal enhancement (PT) of every 3 x 3 pixel was depicted by a gray scale throughout an area of maximal horizontal slice of CT of the liver to obtain blood flow mapping of the liver, and compared with those of normal, chronic hepatitis and cirrhosis. Mottles of deep gray, light gray or black pixels were distributed throughout the liver slice of fatty liver. Although the mean PT of a ROI of fatty liver was longer than normal and shorter than that of cirrhosis and the same as that of chronic hepatitis, the map of fatty liver was different from that of chronic hepatitis. When the distribution of PT was expressed by their histogram, it was known that PT of fatty liver had a wider range than that of chronic hepatitis. The range was the same as that of cirrhosis. In one case of fatty liver, the deep gray pixels was increased when fatty infiltration of the liver was improved. It was concluded that the intrahepatic blood flow of fatty liver was impaired in a way not similar to chronic hepatitis or liver cirrhosis, which could be clearly seen by hepatic blood flow mapping, and which seemed to be reversible with the improvement of fatty liver. (author)

  6. Predictors of antegrade flow at internal carotid artery during carotid artery stenting with proximal protection.

    Science.gov (United States)

    Harada, Kei; Kakumoto, Kosuke; Oshikata, Shogo; Fukuyama, Kozo

    2018-06-01

    Carotid artery stenting (CAS) with proximal occlusion effectively prevent distal cerebral embolism by flow arrest at internal carotid artery (ICA); however, the method can expose antegrade flow at ICA due to incomplete flow arrest. The aim of this study was to identify predictors of antegrade flow during CAS with proximal protection. We retrospectively analyzed clinical and angiographic data among 143 lesions treated with CAS with proximal protection by occluding the common carotid artery (CCA) and external carotid artery (ECA). Flow arrest or antegrade flow at ICA was confirmed by contrast injection during proximal protection. Antegrade flow at ICA was observed in 12 lesions (8.4%). Compared with lesions in which flow arrest of ICA was achieved, the diameter of the superior thyroid artery (STA) was significantly larger (2.4 ± 0.34 vs. 1.4 ± 0.68 mm, p protection should be combined with proximal protection for the lesions with antegrade flow to prevent distal migration of the carotid debris.

  7. Treatment of unresectable primary and metastatic liver cancer with yttrium-90 microspheres (TheraSphere): assessment of hepatic arterial embolization.

    Science.gov (United States)

    Sato, Kent; Lewandowski, Robert J; Bui, James T; Omary, Reed; Hunter, Russell D; Kulik, Laura; Mulcahy, Mary; Liu, David; Chrisman, Howard; Resnick, Scott; Nemcek, Albert A; Vogelzang, Robert; Salem, Riad

    2006-01-01

    In Canada and Europe, yttrium-90 microspheres (TheraSphere); MDS Nordion, Ottawa, Canada) are a primary treatment option for primary and secondary hepatic malignancies. We present data from 30 patients with hepatocellular carcinoma (HCC) and metastatic liver disease treated with TheraSphere from a single academic institution to evaluate the angiographically evident embolization that follows treatment. Seven interventional radiologists from one treatment center compared pretreatment and posttreatment angiograms. The reviewers were blinded to the timing of the studies. The incidence of postembolization syndrome (PES) was determined as well as objective tumor response rates by the World Health Organization (WHO), Response Evaluation Criteria in Solid Tumors (RECIST), and European Association for the Study of the Liver (EASL) criteria. There were 420 independent angiographic observations that were assessed using the chi-squared statistic. The pretreatment and posttreatment angiograms could not be correctly identified on average more than 43% of the time (p = 0.0004). The postprocedure arterial patency rate was 100%. The objective tumor response rates for all patients were 24%, 31%, and 72% for WHO, RECIST, and EASL criteria, respectively. All of the patients tolerated the procedure without complications and were treated on an outpatient basis, and four patients had evidence of PES. This treatment method does not result in macroscopic embolization of the hepatic arteries, thereby maintaining hepatic tissue perfusion. These data support the principle that the favorable response rates reported with TheraSphere are likely due to radiation and microscopic embolization rather than flow-related macroscopic embolization and ischemia.

  8. Analysis of liver blood flow by dynamic hepatic scintigraphy

    International Nuclear Information System (INIS)

    Xie Tianhao; Jia Shiquan

    1996-01-01

    Liver blood flow was studied in 45 patients with solitary malignant liver cancer, 17 patients with multiple liver metastases, 18 patients with benign liver tumor and 20 control subjects by dynamic hepatic scintigraphy. The hepatic perfusion index (HPI) in control subjects, patients with liver malignant cancer and benign tumor was 0.33 +- 0.069, 0.589 +- 0.084, 0.384 +-0.046 respectively, and the mesenteric fraction (MF) was 0.56 +- 0.054, 0.246 +- 0.064, 0.524 +- 0.086 respectively. In conclusion, flow scintigraphy is a non-invasive, sensitive and repeatable method for detection of liver tumor

  9. The biodistribution and effect on hepatic parenchyma with intraarterial injected I-131 lipiodol into hepatic artery

    International Nuclear Information System (INIS)

    Kim, Dong Ik; Suh, Jung Ho; Yoo, Hyung Sik; Lee, Jong Tae; Kim, Ki Whang; Park, Chan Il; Kim, Byung Ro

    1989-01-01

    Iodized oil has been used as a contrast agent in lymphangiography. One of the commercially available compounds is Lipidol Ultra-fluid(LUF) which contains 38% iodine by weight. Nakakuma et al(1979) reported that LUF was selectively retained in the hypervascular hepatocellular carcinoma when injected directly into the ligated hepatic artery. Since that time, it has been widely utilized in the detection as well as the therapeutic attempts of hepatocellular carcinoma, where it has been mixed with chemotherapeutic agents or labeled with radioactive I-131. Like all significant advances, the mechanism of lipid retention within the hepatocellular carcinoma is not clearly understood, and also there is a lack of information about the biodistribution and kinetics of I-131 Lipiodol. The apparent safety of this technique require confirmation. The present study was aimed to assess the biodistribution and kinetics of intraarterially injected I-131 Lipiodol and the histologic changes in canine livers. It was also to verify the safety of this technique in clinical applications. Radioactive iodized oil was obtained by simple exchange method . 518 ± 19 MBq(14 mCi, about 1 mCi/kg body weight) of I-131 Lipiodol was injected intraarterially in 12 dogs as a experimental group. Serial count rates over the livers under gamma camera were measured, and then it was compared with quantitative analysis of radioactivities distributed in liver, lung, spleen, kidney, thyroid, bile and circulating blood using dose calibrator after sacrifice at various time intervals. Cumulative radiation doses were calculated by Quimby method. The effect of I-131 lipiodol on hepatic function were analysed by serial liver function tests after intrahepatic injection of I-131 Lipiodol and compared with preinjection values. Liver tissue obtained after sacrifice were stained with hematoxylin-eosin, Oil red-O, and also election microscopic examinations were performed. The results were summarized as follows; 1

  10. Successful Control of Liver Metastases From Pancreatic Solid-Pseudopapillary Neoplasm (SPN) Using Hepatic Arterial Embolization

    Energy Technology Data Exchange (ETDEWEB)

    Violari, Elena G., E-mail: eviolari@live.com; Brody, Lynn A.; Covey, Anne M.; Erinjeri, Joseph P.; Getrajdman, George I.; Sofocleous, Constantinos T. [Memorial Sloan-Kettering Cancer Center, Department of Radiology, Interventional Radiology Service (United States); Reidy, Diane L. [Memorial Sloan-Kettering Cancer Center, Department of Medicine, Gastrointestinal Oncology Service (United States); Jarnagin, William R. [Memorial Sloan-Kettering Cancer Center, Department of Surgery, Hepatopancreatobiliary Service (United States); Brown, Karen T. [Memorial Sloan-Kettering Cancer Center, Department of Radiology, Interventional Radiology Service (United States)

    2015-04-15

    No systemic agents that are known to be effective for the treatment of solid-pseudopapillary neoplasm (SPN) are available. We report the prolonged and sustained control of metastatic pancreatic SPN to the liver using hepatic arterial embolization (HAE), where a total of 13 HAE sessions were performed over a 6-year period.

  11. Hepatic artery aneurysm simulating a lesion in the head of the pancreas: a case report

    International Nuclear Information System (INIS)

    Pinto, Oswaldo Luiz; Camargo, Jose Gonzaga; Tornin, Olger de Souza; Botelho, Renato Assayag; Menezes, Marcelo Carneiro; Chagas, Jose Francisco Sales; Souza, Ricardo Pires de

    2005-01-01

    The aim of this study is to report a rare case of hepatic artery aneurysm simulating a lesion in the head of the pancreas. A precise evaluation using computed tomography and magnetic resonance imaging is important in the treatment planning, which will influence the prognosis. (author)

  12. Hepatic artery aneurysm in a patient with Behcet's disease and segmental pancreatitis developing after its embolization

    International Nuclear Information System (INIS)

    Oto, A.; Cekirge, S.; Guelsuen, M.; Balkanci, F.; Besim, A.

    2000-01-01

    Segmental pancreatitis is an unusual form of acute pancreatitis mostly seen in the head of pancreas. We present the CT findings of a segmental pancreatitis in the body and tail of the pancreas developed following endovascular embolization of a giant hepatic artery aneurysm and arterioportal fistula in a patient with Behcet's disease. (orig.)

  13. CT detection of daughter nodules in hepatocellular carcinoma after lipiodol infusion via the hepatic artery

    Energy Technology Data Exchange (ETDEWEB)

    Ohishi, Hajime; Ohgami, Syoichi; Katsuragi, Masami

    1985-02-01

    The detectability of daughter nodules in 80 hepatocellular carcinomas was compared between CT assisted by Lipiodol Ultra Fluid (Lipiodol) infused via the hepatic artery and IHA (Infusion hepatic angiography). Lipiodol infused via the hepatic artery was selectively accumulated in the tumor vessels and the tumors and small daughter nodules appeared as markedly high density areas by CT. 18 cases in which the daughter nodules were detected were identified only by CT. Furthermore, in 38 cases CT demonstrated superior detectability of the daughthr nodules than IHA. In 15 cases the daughter nodules were newly detected in areas other than the invaded area where the primary tumor existed. This method is very effective in the diagnosis of daughter nodules of hepatocellular carcinoma. (author).

  14. The experimental studies of Chinese herbs as a vascular embolization agent for the hepatic arteries

    International Nuclear Information System (INIS)

    Chen Ziqian; Yang Xizhang; Shen Junjie; Wang Shudong; Zheng Xiaogang; Cao Jianmin

    2006-01-01

    Objective: To study the efficacy, safety and correlative characteristics of Chinese herb as a vascular embolization agent. Methods: Vascular embolization agent combined from several kinds of Chinese herb was manufactured and served as anticarcinogen and coagulant according to the chinese Pharmacopoeia. The characteristics of the combination embolization agent through embolizing the hepatic arteries in eight pigs were studied. Results: The combination agent was a non-homogenous suspension, easily to be injected through 5-F catheter with hyper attenuation under fluoroscopy; simultaneously with good histocompatibility and hemo-compatibility and without feverish response and toxicity. The combination agent mainly embolized the peripheral arteries with maintaining occlusion for 5 weeks and without formation of collateral circulation. Slight injuries of normal hepatic tissues with hepatic cytonecrosis and endochyloma focal necrosis were found through optical and electronic microscopy. Conclusions: The Chinese herb combination agent is safe and effective in experimental application with good angioembolic function and a potential peripheral embolization agent. (authors)

  15. Percutaneous hepatic arterial catheterization for infusion chemotherapy in treatment of primary hepatoma

    International Nuclear Information System (INIS)

    Juhn, Jae Ryang; Chang, Jae Yong; Cha, Seong Sook; Han, Sang Suk; Bae, Cheol; Kim, Sung Rok; Chae, Yoo Soon

    1984-01-01

    Chemotherapy offers palliative treatment to patient with advanced nonresectable hepatoma. The usefulness of systemic chemotherapy is limited because of serious side reaction and low concentration of drug at tumor. But this problem may be overcome by intraarterial infusion. Nonsurgical percutaneous hepatic arterial catheterization was done in 21 patients with primary hepatoma, and infusion chemotherapy was done in 19 patients who were successful in catheterization. The results were as follows: 1. Selective catheterization of hepatic artery proper, common hepatic artery, and celiac artery were successful in 4, 9 and 4 patients respectively. The success rate of selective catheterization is 80.9% including celiac artery among 21 patients with hepatoma. 2. Simple catheterization method was applied in 14 patients, and catheter exchange and Loop methods were applied in 2 and 1 patient respectively. 3. Complication related to catheterization, such as infection and bleeding on punctured site, intimal injury and dislodgement of catheter were not serious. 4. Drugs were well tolerated without serious toxicity or complication. 5. 3 patients showed objective response and median survival time of treated patients is 2.5 months.

  16. Single photon emission computed tomographic studies (SPECT) of hepatic arterial perfusion scintigraphy (HAPS) in patients with colorectal liver metastases: improved tumour targetting by microspheres with angiotensin II.

    Science.gov (United States)

    Goldberg, J A; Bradnam, M S; Kerr, D J; McKillop, J H; Bessent, R G; McArdle, C S; Willmott, N; George, W D

    1987-12-01

    As intra-arterial chemotherapy for liver metastases of colorectal origin becomes accepted, methods of further improving drug delivery to the tumour have been devised. Degradable microspheres have been shown to reduce regional blood flow by transient arteriolar capillary block, thereby improving uptake of a co-administered drug, when injected into the hepatic artery. In our study of five patients, we combined hepatic arterial perfusion scintigraphy (HAPS) and SPECT to assess the localization of approximately 1 X 10(5) labelled microspheres of human serum albumin (99Tcm MSA) in tumour. In addition, in three patients, we assessed the effect of an intra-arterial infusion of the vasoactive agent angiotension II during HAPS. Results were interpreted by comparing transaxial slices with corresponding slices of a tin colloid liver-spleen scan. Two of five patients showed good localization of 99Tcm MSA in tumour without an angiotensin II infusion. Of the three patients receiving angiotensin II, all showed good tumour targetting with the vasoconstrictor compared with only one of these three before its use. Thus, hepatic arterial infusion of angiotensin II greatly improves microsphere localization in tumour in some patients with colorectal liver metastases. This technique may be useful in the assessment of tumour targetting before and during locoregional therapy.

  17. ANATOMIC VARIATIONS OF HEPATIC ARTERY: A STUDY IN 479 LIVER TRANSPLANTATIONS.

    Science.gov (United States)

    Fonseca-Neto, Olival Cirilo Lucena da; Lima, Heloise Caroline de Souza; Rabelo, Priscylla; Melo, Paulo Sérgio Vieira de; Amorim, Américo Gusmão; Lacerda, Cláudio Moura

    2017-01-01

    The incidence of anatomic variations of hepatic artery ranges from 20-50% in different series. Variations are especially important in the context of liver orthotopic transplantation, since, besides being an ideal opportunity for surgical anatomical study, their precise identification is crucial to the success of the procedure. To identify the anatomical variations in the hepatic arterial system in hepatic transplantation. 479 medical records of transplanted adult patients in the 13-year period were retrospectively analyzed, and collected data on hepatic arterial anatomy of the deceased donor. It was identified normal hepatic arterial anatomy in 416 donors (86.84%). The other 63 patients (13.15%) showed some variation. According to the Michels classification, the most frequently observed abnormalities were: right hepatic artery branch of superior mesenteric artery (Type III, n=27, 5.63%); left hepatic artery branch of the left gastric artery (Type II, n=13, 2.71%); right hepatic artery arising from the superior mesenteric artery associated with the left hepatic artery arising from the left gastric artery (Type IV, n=4, 0.83%). Similarly, in relation to Hiatt classification, the most prevalent changes were: right hepatic accessory artery or substitute of the superior mesenteric artery (Type III, n=28, 6.05%)), followed by liver ancillary left artery or replacement of gastric artery left (Type II, n=16, 3.34. Fourteen donors (2.92%) showed no anatomical abnormalities defined in classifications, the highest frequency being hepatomesenteric trunk identified in five (01.04%). Detailed knowledge of the variations of hepatic arterial anatomy is of utmost importance to surgeons who perform approaches in this area, particularly in liver transplantation, since their identification and proper management are critical to the success of the procedure. A incidência das variações anatômicas da artéria hepática varia de 20-50% em diferentes casuísticas. Elas s

  18. Hepatic Arterial Configuration in Relation to the Segmental Anatomy of the Liver; Observations on MDCT and DSA Relevant to Radioembolization Treatment

    International Nuclear Information System (INIS)

    Hoven, Andor F. van den; Leeuwen, Maarten S. van; Lam, Marnix G. E. H.; Bosch, Maurice A. A. J. van den

    2015-01-01

    PurposeCurrent anatomical classifications do not include all variants relevant for radioembolization (RE). The purpose of this study was to assess the individual hepatic arterial configuration and segmental vascularization pattern and to develop an individualized RE treatment strategy based on an extended classification.MethodsThe hepatic vascular anatomy was assessed on MDCT and DSA in patients who received a workup for RE between February 2009 and November 2012. Reconstructed MDCT studies were assessed to determine the hepatic arterial configuration (origin of every hepatic arterial branch, branching pattern and anatomical course) and the hepatic segmental vascularization territory of all branches. Aberrant hepatic arteries were defined as hepatic arterial branches that did not originate from the celiac axis/CHA/PHA. Early branching patterns were defined as hepatic arterial branches originating from the celiac axis/CHA.ResultsThe hepatic arterial configuration and segmental vascularization pattern could be assessed in 110 of 133 patients. In 59 patients (54 %), no aberrant hepatic arteries or early branching was observed. Fourteen patients without aberrant hepatic arteries (13 %) had an early branching pattern. In the 37 patients (34 %) with aberrant hepatic arteries, five also had an early branching pattern. Sixteen different hepatic arterial segmental vascularization patterns were identified and described, differing by the presence of aberrant hepatic arteries, their respective vascular territory, and origin of the artery vascularizing segment four.ConclusionsThe hepatic arterial configuration and segmental vascularization pattern show marked individual variability beyond well-known classifications of anatomical variants. We developed an individualized RE treatment strategy based on an extended anatomical classification

  19. Effect of intra-hepatic arterial infusion chemotherapy for patients with liver metastasis from breast cancer

    International Nuclear Information System (INIS)

    Liu Dezhong; Li Huai; Zeng Huiying; Yang Ling

    2001-01-01

    Objective: To evaluate the efficacy of intra-hepatic arterial infusion chemotherapy for patients with liver metastasis from breast cancer. Methods: 1993-1998 years, Thirty four patients with liver metastasis from breast cancer had received epi-adriamycin, cisplatin, mitomycin and 5-fluorouracil by intrahepatic arterial infusion chemotherapy. Twelve patients had received embolization. Results: Six patients (17.65%) had a complete response, 12 patients (35.29%) had a partial response. The overall response rate was 52.94%. Cumulative survival rates at 1, 2, 3 and 4 years were 56.90%, 25.00%, 5.00% and 5.00% respectively (Kaplan-Meier method). The median overall survival time was 11.5 months. Conclusion: Intra-hepatic arterial infusion chemotherapy is safe and effective for liver metastasis from breast cancer and should be the first choice of treatment for these patients

  20. Segmentation of hepatic artery in multi-phase liver CT using directional dilation and connectivity analysis

    Science.gov (United States)

    Wang, Lei; Schnurr, Alena-Kathrin; Zidowitz, Stephan; Georgii, Joachim; Zhao, Yue; Razavi, Mohammad; Schwier, Michael; Hahn, Horst K.; Hansen, Christian

    2016-03-01

    Segmentation of hepatic arteries in multi-phase computed tomography (CT) images is indispensable in liver surgery planning. During image acquisition, the hepatic artery is enhanced by the injection of contrast agent. The enhanced signals are often not stably acquired due to non-optimal contrast timing. Other vascular structure, such as hepatic vein or portal vein, can be enhanced as well in the arterial phase, which can adversely affect the segmentation results. Furthermore, the arteries might suffer from partial volume effects due to their small diameter. To overcome these difficulties, we propose a framework for robust hepatic artery segmentation requiring a minimal amount of user interaction. First, an efficient multi-scale Hessian-based vesselness filter is applied on the artery phase CT image, aiming to enhance vessel structures with specified diameter range. Second, the vesselness response is processed using a Bayesian classifier to identify the most probable vessel structures. Considering the vesselness filter normally performs not ideally on the vessel bifurcations or the segments corrupted by noise, two vessel-reconnection techniques are proposed. The first technique uses a directional morphological operator to dilate vessel segments along their centerline directions, attempting to fill the gap between broken vascular segments. The second technique analyzes the connectivity of vessel segments and reconnects disconnected segments and branches. Finally, a 3D vessel tree is reconstructed. The algorithm has been evaluated using 18 CT images of the liver. To quantitatively measure the similarities between segmented and reference vessel trees, the skeleton coverage and mean symmetric distance are calculated to quantify the agreement between reference and segmented vessel skeletons, resulting in an average of 0:55+/-0:27 and 12:7+/-7:9 mm (mean standard deviation), respectively.

  1. Regional blood flow analysis and its relationship with arterial branch lengths and lumen volume in the coronary arterial tree

    International Nuclear Information System (INIS)

    Molloi, Sabee; Wong, Jerry T

    2007-01-01

    The limitations of visually assessing coronary artery disease are well known. These limitations are particularly important in intermediate coronary lesions (30-70% diameter stenosis) where it is difficult to determine whether a particular lesion is the cause of ischaemia. Therefore, a functional measure of stenosis severity is needed. The purpose of this study is to determine whether the expected maximum coronary blood flow in an arterial tree is predictable from its sum of arterial branch lengths or lumen volume. Using a computer model of a porcine coronary artery tree, an analysis of blood flow distribution was conducted through a network of millions of vessels that included the entire coronary artery tree down to the first capillary branch. The flow simulation results show that there is a linear relationship between coronary blood flow and the sum of its arterial branch lengths. This relationship holds over the entire arterial tree. The flow simulation results also indicate that there is a 3/4 er relation between coronary blood flow (Q) and the sum of its arterial lumen volume (V). Moreover, there is a linear relationship between normalized Q and normalized V raised to a power of 3/4 over the entire arterial tree. These results indicate that measured arterial branch lengths or lumen volumes can be used to predict the expected maximum blood flow in an arterial tree. This theoretical maximum blood flow, in conjunction with an angiographically measured blood flow, can potentially be used to calculate fractional flow reserve based entirely on angiographic data

  2. Anatomical variations of the celiac trunk and hepatic arterial system: an analysis using multidetector computed tomography angiography

    Energy Technology Data Exchange (ETDEWEB)

    Araujo Neto, Severino Aires; Franca, Henrique Almeida; Mello Junior, Carlos Fernando de; Silva Neto, Eulampio Jose; Negromonte, Gustavo Ramalho Pessoa; Duarte, Claudia Martina Araujo; Cavalcanti Neto, Bartolomeu Fragoso; Farias, Rebeca Danielly da Fonseca, E-mail: severinoaires@hotmail.com [Universidade Federal da Paraiba (UFPB), Joao Pessoa, PB (Brazil)

    2015-11-15

    Objective: To analyze the prevalence of anatomical variations of celiac arterial trunk (CAT) branches and hepatic arterial system (HAS), as well as the CAT diameter, length and distance to the superior mesenteric artery. Materials And Methods: Retrospective, cross-sectional and predominantly descriptive study based on the analysis of multidetector computed tomography images of 60 patients. Results: The celiac trunk anatomy was normal in 90% of cases. Hepatosplenic trunk was found in 8.3% of patients, and hepatogastric trunk in 1.7%. Variation of the HAS was observed in 21.7% of cases, including anomalous location of the right hepatic artery in 8.3% of cases, and of the left hepatic artery, in 5%. Also, cases of joint relocation of right and left hepatic arteries, and trifurcation of the proper hepatic artery were observed, respectively, in 3 (5%) and 2 (3.3%) patients. Mean length and caliber of the CAT were 2.3 cm and 0.8 cm, respectively. Mean distance between CAT and superior mesenteric artery was 1.2 cm (standard deviation = 4.08). A significant correlation was observed between CAT diameter and length, and CAT diameter and distance to superior mesenteric artery. Conclusion: The pattern of CAT variations and diameter corroborate the majority of the literature data. However, this does not happen in relation to the HAS. (author)

  3. Anatomical variations of the celiac trunk and hepatic arterial system: an analysis using multidetector computed tomography angiography

    International Nuclear Information System (INIS)

    Araujo Neto, Severino Aires; Franca, Henrique Almeida; Mello Junior, Carlos Fernando de; Silva Neto, Eulampio Jose; Negromonte, Gustavo Ramalho Pessoa; Duarte, Claudia Martina Araujo; Cavalcanti Neto, Bartolomeu Fragoso; Farias, Rebeca Danielly da Fonseca

    2015-01-01

    Objective: To analyze the prevalence of anatomical variations of celiac arterial trunk (CAT) branches and hepatic arterial system (HAS), as well as the CAT diameter, length and distance to the superior mesenteric artery. Materials And Methods: Retrospective, cross-sectional and predominantly descriptive study based on the analysis of multidetector computed tomography images of 60 patients. Results: The celiac trunk anatomy was normal in 90% of cases. Hepatosplenic trunk was found in 8.3% of patients, and hepatogastric trunk in 1.7%. Variation of the HAS was observed in 21.7% of cases, including anomalous location of the right hepatic artery in 8.3% of cases, and of the left hepatic artery, in 5%. Also, cases of joint relocation of right and left hepatic arteries, and trifurcation of the proper hepatic artery were observed, respectively, in 3 (5%) and 2 (3.3%) patients. Mean length and caliber of the CAT were 2.3 cm and 0.8 cm, respectively. Mean distance between CAT and superior mesenteric artery was 1.2 cm (standard deviation = 4.08). A significant correlation was observed between CAT diameter and length, and CAT diameter and distance to superior mesenteric artery. Conclusion: The pattern of CAT variations and diameter corroborate the majority of the literature data. However, this does not happen in relation to the HAS. (author)

  4. Biliary Cast Syndrome: Hepatic Artery Resistance Index, Pathological Changes, Morphology and Endoscopic Therapy

    Directory of Open Access Journals (Sweden)

    Hu Tian

    2015-01-01

    Full Text Available Background: Biliary cast syndrome (BCS was a postoperative complication of orthotopic liver transplantation (OLT, and the reason for BSC was considered to relate with ischemic type biliary lesions. This study aimed to evaluate the relationship between BCS following OLT and the hepatic artery resistance index (HARI, and to observe pathological changes and morphology of biliary casts. Methods: Totally, 18 patients were diagnosed with BCS by cholangiography following OLT using choledochoscope or endoscopic retrograde cholangiopancreatography. In addition, 36 patients who did not present with BCS in the corresponding period had detectable postoperative HARI on weeks 1, 2, 3 shown by color Doppler flow imaging. The compositions of biliary casts were analyzed by pathological examination and scanning electron microscopy. Results: HARI values of the BCS group were significantly decreased as compared with the non-BCS group on postoperative weeks 2 and 3 (P 1 (OR = 1.300; 1.223; and 1.889, respectively. The OR of HARI 3 was statistically significant (OR = 1.889; 95% confidence interval = 1.166-7.490; P = 0.024. The compositions of biliary casts were different when bile duct stones were present. Furthermore, vascular epithelial cells were found by pathological examination in biliary casts. Conclusions: HARI may possibly serve as an independent risk factor and early predictive factor of BCS. Components and formation of biliary casts and bile duct stones are different.

  5. Haemodynamic changes in hepatocellular carcinoma and liver parenchyma under balloon occlusion of the hepatic artery

    Energy Technology Data Exchange (ETDEWEB)

    Sugihara, Fumie; Murata, Satoru; Ueda, Tatsuo; Yasui, Daisuke; Yamaguchi, Hidenori; Miki, Izumi; Kumita, Shin-ichiro [Nippon Medical School, Department of Radiology, Center for Advanced Medical Technology, Tokyo (Japan); Kawamoto, Chiaki [Nippon Medical School, Department of Internal Medicine, Tokyo (Japan); Uchida, Eiji [Nippon Medical School, Department of Surgery, Tokyo (Japan)

    2017-06-15

    To investigate haemodynamic changes in hepatocellular carcinoma (HCC) and liver under hepatic artery occlusion. Thirty-eight HCC nodules in 25 patients were included. Computed tomography (CT) during hepatic arteriography (CTHA) with and without balloon occlusion of the hepatic artery was performed. CT attenuation and enhancement volume of HCC and liver with and without balloon occlusion were measured on CTHA. Influence of balloon position (segmental or subsegmental branch) was evaluated based on differences in HCC-to-liver attenuation ratio (H/L ratio) and enhancement volume of HCC and liver. In the segmental group (n = 20), H/L ratio and enhancement volume of HCC and liver were significantly lower with balloon occlusion than without balloon occlusion. However, in the subsegmental group (n = 18), H/L ratio was significantly higher and liver enhancement volume was significantly lower with balloon occlusion; HCC enhancement volume was similar with and without balloon occlusion. Rate of change in H/L ratio and enhancement volume of HCC and liver were lower in the segmental group than in the subsegmental group. There were significantly more perfusion defects in HCC in the segmental group. Hepatic artery occlusion causes haemodynamic changes in HCC and liver, especially with segmental occlusion. (orig.)

  6. Comparison of high-resolution contrast-enhanced 3D MRA with digital subtraction angiography in the evaluation of hepatic arterial anatomy

    International Nuclear Information System (INIS)

    Matoba, M.; Tonami, H.; Kuginuki, M.; Yokota, H.; Takashima, S.; Yamamoto, I.

    2003-01-01

    AIM: To evaluate the validity of high-resolution contrast-enhanced three-dimensional magnetic resonance angiography (MRA) in defining hepatic arterial anatomy and to compare this with digital subtraction angiography (DSA). MATERIALS AND METHODS: MRA and DSA were performed in 30 patients. MRA was performed with breath-hold, gadolinium-enhanced, three-dimensional, fast low-angle shot sequence with a 512 pixel matrix. MRA was compared with DSA in terms of image quality and depiction of hepatic arterial anatomy. The agreement in image quality between MRA and DSA was determined with the kappa statistic. RESULTS: With respect to image quality, there was excellent or good correlation between MRA and DSA for the common hepatic artery (κ=0.85), proper hepatic artery (κ=0.72), gastroduodenal artery (κ=0.70), left hepatic artery (κ=0.49), left gastric artery (κ=0.50), splenic artery (κ=0.84), and superior mesenteric artery (κ=0.88). Poor correlation was found for the right hepatic artery (κ=0.18) and right gastric artery (κ=0.38). With regard to hepatic arterial anatomy, MRA correlated correctly with DSA in 28 of the 29 cases, i.e. 97% of patients. CONCLUSION: MRA is a useful technique for the evaluation of the hepatic artery, and for the vast majority of patients, MRA can replace intra-arterial DSA

  7. Unsteady 3D flow simulations in cranial arterial tree

    Science.gov (United States)

    Grinberg, Leopold; Anor, Tomer; Madsen, Joseph; Karniadakis, George

    2008-11-01

    High resolution unsteady 3D flow simulations in major cranial arteries have been performed. Two cases were considered: 1) a healthy volunteer with a complete Circle of Willis (CoW); and 2) a patient with hydrocephalus and an incomplete CoW. Computation was performed on 3344 processors of the new half petaflop supercomputer in TACC. Two new numerical approaches were developed and implemented: 1) a new two-level domain decomposition method, which couples continuous and discontinuous Galerkin discretization of the computational domain; and 2) a new type of outflow boundary conditions, which imposes, in an accurate and computationally efficient manner, clinically measured flow rates. In the first simulation, a geometric model of 65 cranial arteries was reconstructed. Our simulation reveals a high degree of asymmetry in the flow at the left and right parts of the CoW and the presence of swirling flow in most of the CoW arteries. In the second simulation, one of the main findings was a high pressure drop at the right anterior communicating artery (PCA). Due to the incompleteness of the CoW and the pressure drop at the PCA, the right internal carotid artery supplies blood to most regions of the brain.

  8. Partial Portal Vein Arterialization Attenuates Acute Bile Duct Injury Induced by Hepatic Dearterialization in a Rat Model.

    Science.gov (United States)

    Jiang, Jun; Wei, Jishu; Wu, Junli; Gao, Wentao; Li, Qiang; Jiang, Kuirong; Miao, Yi

    2016-01-01

    Hepatic infarcts or abscesses occur after hepatic artery interruption. We explored the mechanisms of hepatic deprivation-induced acute liver injury and determine whether partial portal vein arterialization attenuated this injury in rats. Male Sprague-Dawley rats underwent either complete hepatic arterial deprivation or partial portal vein arterialization, or both. Hepatic ischemia was evaluated using biochemical analysis, light microscopy, and transmission electron microscopy. Hepatic ATP levels, the expression of hypoxia- and inflammation-associated genes and proteins, and the expression of bile transporter genes were assessed. Complete dearterialization of the liver induced acute liver injury, as evidenced by the histological changes, significantly increased serum biochemical markers, decreased ATP content, increased expression of hypoxia- and inflammation-associated genes and proteins, and decreased expression of bile transporter genes. These detrimental changes were extenuated but not fully reversed by partial portal vein arterialization, which also attenuated ductular reaction and fibrosis in completely dearterialized rat livers. Collectively, complete hepatic deprivation causes severe liver injury, including bile infarcts and biloma formation. Partial portal vein arterialization seems to protect against acute ischemia-hypoxia-induced liver injury.

  9. Partial Portal Vein Arterialization Attenuates Acute Bile Duct Injury Induced by Hepatic Dearterialization in a Rat Model

    Directory of Open Access Journals (Sweden)

    Jun Jiang

    2016-01-01

    Full Text Available Hepatic infarcts or abscesses occur after hepatic artery interruption. We explored the mechanisms of hepatic deprivation-induced acute liver injury and determine whether partial portal vein arterialization attenuated this injury in rats. Male Sprague-Dawley rats underwent either complete hepatic arterial deprivation or partial portal vein arterialization, or both. Hepatic ischemia was evaluated using biochemical analysis, light microscopy, and transmission electron microscopy. Hepatic ATP levels, the expression of hypoxia- and inflammation-associated genes and proteins, and the expression of bile transporter genes were assessed. Complete dearterialization of the liver induced acute liver injury, as evidenced by the histological changes, significantly increased serum biochemical markers, decreased ATP content, increased expression of hypoxia- and inflammation-associated genes and proteins, and decreased expression of bile transporter genes. These detrimental changes were extenuated but not fully reversed by partial portal vein arterialization, which also attenuated ductular reaction and fibrosis in completely dearterialized rat livers. Collectively, complete hepatic deprivation causes severe liver injury, including bile infarcts and biloma formation. Partial portal vein arterialization seems to protect against acute ischemia-hypoxia-induced liver injury.

  10. Evaluation of the therapeutic effect of hepatic arterial chemoembolization combined with portal chemoembolization for advanced hepatic carcinomas

    International Nuclear Information System (INIS)

    He Hongde; He Jing; Luo Zhonghua; Xu Jian; Sun Lijun; Li Jingbang; Zhang Xuexin

    2010-01-01

    Objective: To evaluate the effect of transcatheter arterial chemoembolization (TACE) together with portal vein chemoembolization (PVCE) for the treatment of advanced liver carcinomas. Methods: Forty-eight patients with liver carcinoma were randomly divided into two groups. Patients in study group (n = 22) were treated with TACE together with PVCE, and patients in control group (n = 26) were treated with TACE alone. Results: Based on the postoperative CT findings and AFP levels, the effective rate of the study group was markedly higher than that of control group and the difference between two groups was statistically significant (P < 0.05). The volume of un-embolized liver tissue in the patients of study group was obviously increased after treatment. Conclusion: TACE together with PVCE is superior to TACE alone in treating advanced hepatic carcinomas. The combination of TACE and PVCE can effectively increase the successful rate of surgical resection for the advanced hepatic carcinomas. (authors)

  11. Vasopressin-induced changes in splanchnic blood flow and hepatic and portal venous pressures in liver resection.

    Science.gov (United States)

    Bown, L Sand; Ricksten, S-E; Houltz, E; Einarsson, H; Söndergaard, S; Rizell, M; Lundin, S

    2016-05-01

    To minimize blood loss during hepatic surgery, various methods are used to reduce pressure and flow within the hepato-splanchnic circulation. In this study, the effect of low- to moderate doses of vasopressin, a potent splanchnic vasoconstrictor, on changes in portal and hepatic venous pressures and splanchnic and hepato-splanchnic blood flows were assessed in elective liver resection surgery. Twelve patients were studied. Cardiac output (CO), stroke volume (SV), mean arterial (MAP), central venous (CVP), portal venous (PVP) and hepatic venous pressures (HVP) were measured, intraoperatively, at baseline and during vasopressin infusion at two infusion rates (2.4 and 4.8 U/h). From arterial and venous blood gases, the portal (splanchnic) and hepato-splanchnic blood flow changes were calculated, using Fick's equation. CO, SV, MAP and CVP increased slightly, but significantly, while systemic vascular resistance and heart rate remained unchanged at the highest infusion rate of vasopressin. PVP was not affected by vasopressin, while HVP increased slightly. Vasopressin infusion at 2.4 and 4.8 U/h reduced portal blood flow (-26% and -37%, respectively) and to a lesser extent hepato-splanchnic blood flow (-9% and -14%, respectively). The arterial-portal vein lactate gradient was not significantly affected by vasopressin. Postoperative serum creatinine was not affected by vasopressin. Short-term low to moderate infusion rates of vasopressin induced a splanchnic vasoconstriction without metabolic signs of splanchnic hypoperfusion or subsequent renal impairment. Vasopressin caused a centralization of blood volume and increased cardiac output. Vasopressin does not lower portal or hepatic venous pressures in this clinical setting. © 2016 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  12. Hepatic Artery Mycotic Aneurysm Associated with Staphylococcal Endocarditis with Successful Treatment: Case Report with Review of the Literature

    Directory of Open Access Journals (Sweden)

    Dhara Chaudhari

    2013-01-01

    Full Text Available Mycotic hepatic artery aneurysm is a vascular pathology associated with bacterial endocarditis. It is rare in occurrence after the introduction of effective antibiotics. We present a young patient with injection drug abuse associated staphylococcal endocarditis which was successfully treated with antibiotics and valve replacement who presented with abdominal pain. He was found to have mycotic aneurysm of hepatic artery which was successfully treated with coil embolization.

  13. In vitro and in vivo studies of pulmonary artery flow

    International Nuclear Information System (INIS)

    Sahn, D.J.; Yoganathan, A.P.

    1986-01-01

    A variety of interesting intracardiac flow patterns have been recorded by pulsed and continuous wave Doppler technologies in humans with heart disease. Some of these patterns have, in fact, been difficult to explain and are now more easily understood using color Doppler flow mapping systems which show the spatial location of flow. The authors performed a number of studies in patients, as well as studies in in vitro systems to model some of the phenomenon that the authors observed in the pulmonary artery. Their studies with Doppler flow mapping in the clinical situation, in the in vitro model, and in the animal models of congenital heart disorders lend insights into the complex hydrodynamics present in the pulmonary artery

  14. Nocturnal foot blood flow in patients with arterial insufficiency

    DEFF Research Database (Denmark)

    Jelnes, Rolf; Tønnesen, K H

    1984-01-01

    Twenty-four hour continuous recording of xenon (133Xe) wash-out from the forefoot was performed on patients with normal circulations (n = 10) and on patients with different degrees of arterial insufficiency (n = 36). During day hours the calculated subcutaneous blood flow in the forefoot was on a...

  15. Clinical Analysis of Pulmonary Lipiodol Embolism in Patients with Hepatic Carcinoma after Transcatheter Arterial Chemoembolization

    Directory of Open Access Journals (Sweden)

    Wen-jin JIANG

    2015-03-01

    Full Text Available Objective:To explore the clinical manifestations, therapeutic methods and preventive measures of pulmonary lipiodol embolism (PLE induced by transcatheter arterial chemoembolization (TACE so as to improve the cognition and management of PLE. Methods:A total of 2 613 patients with hepatic cancer without history of pulmonary disease who were treated with TACE in our hospital from Sept., 2004 to Mar., 2013 were selected. The clinical manifestations, therapeutic methods and preventing measures of the 9 patients who were accompanied with PLE were observed to analyze the pre-operative hepatic computed tomography (CT and chest X-ray, intra-operative contrast examination, dosage of lipiodol and chemotherapeutic drugs, clinical manifestation and therapeutic progression as well as the postoperative follow-up.Results: Nine patients accompanied by PLE had different-severity cough, hemoptysis and progressive dyspnea, and chest X-ray and/or CT showed flaky high-density radiography. After treated with oxygen inhalation, bronchus expansion and inflammation alleviation, 8 patients were improved but 1 died. Of the 8 patients, 2 were given ventilator to assist breath, and the clinical symptoms of 8 patients disappeared within 3-15 d. The re-examined chest X-ray showed normal after 20-60 d follow-up observation. Additionally, 6 patients were with nidus diameter ≥10 cm, 6 with hepatic artery-vein fistula and 7 with lipiodol dosage ≥20 mL.Conclusion: PLE often occurs in patients with giant hepatic carcinoma accompanied by hepatic artery-vein fistula, whose lipiodol dosage is ≥20 mL. Accurate and correct management during operation can effectively reduce the development of PLE.

  16. Relationship between hemodynamic changes of portal vein and hepatic artery measured by color Doppler ultrasound and FibroScan value in patients with liver cirrhosis

    Directory of Open Access Journals (Sweden)

    CHENG Xiaofei

    2014-11-01

    Full Text Available ObjectiveTo explore the relationship between hemodynamic changes of the portal vein and hepatic artery measured by color Doppler ultrasound and FibroScan value in patients with liver cirrhosis. MethodsA total of 192 patients with hepatitis B cirrhosis who were admitted to our hospital from March 2010 to December 2013, as well as 100 healthy persons, were recruited. The mean portal vein blood flow velocity (PVVmean, hepatic artery pulsatility index (HAPI, and hepatic artery resistance index (HARI were measured by color Doppler ultrasound. FibroScan was also carried out. All data were statistically analyzed using SPSS 13.0. Continuous data were expressed as mean±SD and compared between groups by t-test. ResultsThe HAPI, HARI, and FibroScan value of the patient group were 1.56±024, 0.73±0.05, and 25.38±7.73, respectively, significantly higher than those of the control group (1.36±0.14, 0.65±0.07, and 7.8±3.6 (P<0.05; the PVVmean of the patient group was 14.43±1.86, significantly lower than that of the control group (17.35±0.56 (P<0.05. FibroScan value was positively correlated with HAPI and HARI (r1=0.59, r2=0.66, P<0.001, but negatively correlated with PVVmean (r=-0.64, P<0.001. ConclusionThe liver stiffness assessed by FibroScan and the hemodynamic changes of the portal vein and hepatic artery measured by color Doppler ultrasound are vitally important for evaluating the severity of liver cirrhosis.

  17. Non invasive blood flow measurement in cerebellum detects minimal hepatic encephalopathy earlier than psychometric tests.

    Science.gov (United States)

    Felipo, Vicente; Urios, Amparo; Giménez-Garzó, Carla; Cauli, Omar; Andrés-Costa, Maria-Jesús; González, Olga; Serra, Miguel A; Sánchez-González, Javier; Aliaga, Roberto; Giner-Durán, Remedios; Belloch, Vicente; Montoliu, Carmina

    2014-09-07

    To assess whether non invasive blood flow measurement by arterial spin labeling in several brain regions detects minimal hepatic encephalopathy. Blood flow (BF) was analyzed by arterial spin labeling (ASL) in different brain areas of 14 controls, 24 cirrhotic patients without and 16 cirrhotic patients with minimal hepatic encephalopathy (MHE). Images were collected using a 3 Tesla MR scanner (Achieva 3T-TX, Philips, Netherlands). Pulsed ASL was performed. Patients showing MHE were detected using the battery Psychometric Hepatic Encephalopathy Score (PHES) consisting of five tests. Different cognitive and motor functions were also assessed: alterations in selective attention were evaluated using the Stroop test. Patients and controls also performed visuo-motor and bimanual coordination tests. Several biochemical parameters were measured: serum pro-inflammatory interleukins (IL-6 and IL-18), 3-nitrotyrosine, cGMP and nitrates+nitrites in plasma, and blood ammonia. Bivariate correlations were evaluated. In patients with MHE, BF was increased in cerebellar hemisphere (P = 0.03) and vermis (P = 0.012) and reduced in occipital lobe (P = 0.017). BF in cerebellar hemisphere was also increased in patients without MHE (P = 0.02). Bimanual coordination was impaired in patients without MHE (P = 0.05) and much more in patients with MHE (P battery and with CFF. BF in cerebellar hemisphere correlates with plasma cGMP and nitric oxide (NO) metabolites. BF in vermis cerebellar also correlates with NO metabolites and with 3-nitrotyrosine. IL-18 in plasma correlates with BF in thalamus and occipital lobe. Non invasive BF determination in cerebellum using ASL may detect MHE earlier than the PHES. Altered NO-cGMP pathway seems to be associated to altered BF in cerebellum.

  18. Calculation of arterial wall temperature in atherosclerotic arteries: effect of pulsatile flow, arterial geometry, and plaque structure

    Directory of Open Access Journals (Sweden)

    Kim Taehong

    2007-03-01

    Full Text Available Abstract Background This paper presents calculations of the temperature distribution in an atherosclerotic plaque experiencing an inflammatory process; it analyzes the presence of hot spots in the plaque region and their relationship to blood flow, arterial geometry, and inflammatory cell distribution. Determination of the plaque temperature has become an important topic because plaques showing a temperature inhomogeneity have a higher likelihood of rupture. As a result, monitoring plaque temperature and knowing the factors affecting it can help in the prevention of sudden rupture. Methods The transient temperature profile in inflamed atherosclerotic plaques is calculated by solving an energy equation and the Navier-Stokes equations in 2D idealized arterial models of a bending artery and an arterial bifurcation. For obtaining the numerical solution, the commercial package COMSOL 3.2 was used. The calculations correspond to a parametric study where arterial type and size, as well as plaque geometry and composition, are varied. These calculations are used to analyze the contribution of different factors affecting arterial wall temperature measurements. The main factors considered are the metabolic heat production of inflammatory cells, atherosclerotic plaque length lp, inflammatory cell layer length lmp, and inflammatory cell layer thickness dmp. Results The calculations indicate that the best location to perform the temperature measurement is at the back region of the plaque (0.5 ≤ l/lp ≤ 0.7. The location of the maximum temperature, or hot spot, at the plaque surface can move during the cardiac cycle depending on the arterial geometry and is a direct result of the blood flow pattern. For the bending artery, the hot spot moves 0.6 millimeters along the longitudinal direction; for the arterial bifurcation, the hot spot is concentrated at a single location due to the flow recirculation observed at both ends of the plaque. Focusing on the

  19. Secondary flow structures under stent-induced perturbations for cardiovascular flow in a curved artery model

    International Nuclear Information System (INIS)

    Glenn, Autumn L.; Bulusu, Kartik V.; Shu Fangjun; Plesniak, Michael W.

    2012-01-01

    Secondary flows within curved arteries with unsteady forcing result from amplified centrifugal instabilities and are expected to be driven by the rapid accelerations and decelerations inherent in physiological waveforms. These secondary flows may also affect the function of curved arteries through pro-atherogenic wall shear stresses, platelet residence time and other vascular response mechanisms. Planar PIV measurements were performed under multi-harmonic non-zero-mean and physiological carotid artery waveforms at various locations in a rigid bent-pipe curved artery model. Results revealed symmetric counter-rotating vortex pairs that developed during the acceleration phases of both multi-harmonic and physiological waveforms. An idealized stent model was placed upstream of the bend, which initiated flow perturbations under physiological inflow conditions. Changes in the secondary flow structures were observed during the systolic deceleration phase (t/T ≈ 0.20–0.50). Proper Orthogonal Decomposition (POD) analysis of the flow morphologies under unsteady conditions indicated similarities in the coherent secondary-flow structures and correlation with phase-averaged velocity fields. A regime map was created that characterizes the kaleidoscope of vortical secondary flows with multiple vortex pairs and interesting secondary flow morphologies. This regime map in the curved artery model was created by plotting the secondary Reynolds number against another dimensionless acceleration-based parameter marking numbered regions of vortex pairs.

  20. Secondary flow structures under stent-induced perturbations for cardiovascular flow in a curved artery model

    Energy Technology Data Exchange (ETDEWEB)

    Glenn, Autumn L.; Bulusu, Kartik V. [Department of Mechanical and Aerospace Engineering, George Washington University, 801 22nd Street, NW., Washington, DC 20052 (United States); Shu Fangjun [Department of Mechanical and Aerospace Engineering, New Mexico State University, MSC 3450, P.O. Box 30001, Las Cruces, NM 88003-8001 (United States); Plesniak, Michael W., E-mail: plesniak@gwu.edu [Department of Mechanical and Aerospace Engineering, George Washington University, 801 22nd Street, NW., Washington, DC 20052 (United States)

    2012-06-15

    Secondary flows within curved arteries with unsteady forcing result from amplified centrifugal instabilities and are expected to be driven by the rapid accelerations and decelerations inherent in physiological waveforms. These secondary flows may also affect the function of curved arteries through pro-atherogenic wall shear stresses, platelet residence time and other vascular response mechanisms. Planar PIV measurements were performed under multi-harmonic non-zero-mean and physiological carotid artery waveforms at various locations in a rigid bent-pipe curved artery model. Results revealed symmetric counter-rotating vortex pairs that developed during the acceleration phases of both multi-harmonic and physiological waveforms. An idealized stent model was placed upstream of the bend, which initiated flow perturbations under physiological inflow conditions. Changes in the secondary flow structures were observed during the systolic deceleration phase (t/T Almost-Equal-To 0.20-0.50). Proper Orthogonal Decomposition (POD) analysis of the flow morphologies under unsteady conditions indicated similarities in the coherent secondary-flow structures and correlation with phase-averaged velocity fields. A regime map was created that characterizes the kaleidoscope of vortical secondary flows with multiple vortex pairs and interesting secondary flow morphologies. This regime map in the curved artery model was created by plotting the secondary Reynolds number against another dimensionless acceleration-based parameter marking numbered regions of vortex pairs.

  1. Spatial relationship between intrahepatic artery and portal vein based on the fusion image of CT-arterial portography (CTAP) and CT-angiography (CTA): New classification for hepatic artery at hepatic hilum and the segmentation of right anterior section of the liver

    International Nuclear Information System (INIS)

    Ibukuro, Kenji; Takeguchi, Takaya; Fukuda, Hozumi; Abe, Shoko; Tobe, Kimiko; Tanaka, Rei; Tagawa, Kazumi

    2012-01-01

    Purpose: To clarify the variations of the intrahepatic artery and portal vein and to verify the proper segmentation for the right anterior section of the liver. Materials and methods: CT during arterial portography and CT angiography were performed on 64-slice multi detector row CT in 147 patients. All images were transferred to a workstation for analysis using multi-image-fusion mode. We investigated the spatial relationship between hepatic artery and portal vein in the right hemiliver and the segmentation of the right anterior hepatic artery and portal vein. Results: The spatial anatomy of right hepatic arteries and portal vein was (1) anterior and posterior hepatic artery run superior and inferior to anterior portal vein, respectively (47.6%), (2) one anterior hepatic artery runs superior to and another one runs inferior to anterior portal vein (15%), (3) anterior and posterior hepatic arteries run superior to anterior portal vein (11.6%), (4) anterior and posterior hepatic arteries run inferior to anterior portal vein (7.5%), and (5) one posterior hepatic artery runs superior to and another one runs inferior to anterior portal vein (6.8%). The combined anatomy of right anterior artery and portal vein with regard to segmentation was classified as (1) dorso-ventral (26.5%), (2) dorso-ventral and inferior (10.9%), (3) multiple (18.4%), and (4) superior and inferior segments (1.4%). Conclusion: There are various types of spatial anatomy of intrahepatic artery and portal vein. The hepatic arteries as well as portal veins of right anterior section of the liver could be divided into dorsal and ventral, not superior and inferior.

  2. Hepatic Artery Resection for Bismuth Type III and IV Hilar Cholangiocarcinoma: Is Reconstruction Always Required?

    Science.gov (United States)

    Hu, Hai-Jie; Jin, Yan-Wen; Zhou, Rong-Xing; Shrestha, Anuj; Ma, Wen-Jie; Yang, Qin; Wang, Jun-Ke; Liu, Fei; Cheng, Nan-Sheng; Li, Fu-Yu

    2018-03-06

    The objective of the study is to examine the feasibility of hepatic artery resection (HAR) without subsequent reconstruction (RCS) in specified patients of Bismuth type III and IV hilar cholangiocarcinoma. We retrospectively reviewed 63 patients who underwent hepatic artery resection for Bismuth type III and IV hilar cholangiocarcinoma. These patients were subsequently enrolled into two groups based on whether the artery reconstruction was conducted. Postoperative morbidity and mortality, and long-term survival outcome were compared between the two groups. There were 29 patients in HAR group and 34 patients in the HAR + RCS group. Patients with hepatic artery reconstruction tended to have longer operative time (545.6 ± 143.1 min vs. 656.3 ± 192.8 min; P = 0.013) and smaller tumor size (3.0 ± 1.1 cm vs. 2.5 ± 0.9 cm; P = 0.036). The R0 resection margin was comparable between the HAR group and HAR + RCS group (86.2 vs. 85.3%; P > 0.05). Twelve patients (41.4%) with 24 complications in HAR group and 13 patients (38.2%) with 25 complications in HAR + RCS group were recorded (P = 0.799). The postoperative hepatic failure rate (13.8 vs. 5.9%) and postoperative mortality rate (3.4% vs. 2.9%) were also comparable between the two groups. In the HAR group, the overall 1-, 3-, and 5-year survival rates were 72, 41, and 19%, respectively; while in the HAR + RCS group, the overall 1-, 3-, and 5-year survival rates were 79, 45, and 25%, respectively (P = 0.928). Hepatic artery resection without reconstruction is also a safe and feasible surgical procedure for highly selected cases of Bismuth type III and IV hilar cholangiocarcinoma.

  3. Dopexamine increases internal mammary artery blood flow following coronary artery bypass grafting.

    LENUS (Irish Health Repository)

    Flynn, Michael J

    2012-02-03

    OBJECTIVE: Vasoactive agents and inotropes influence conduit-coronary blood flow following coronary artery bypass grafting (CABG). It was hypothesized that dopexamine hydrochloride, a dopamine A-1 (DA-1) and beta(2) agonist would increase conduit-coronary blood flow. A prospective randomized double blind clinical trial was carried out to test this hypothesis. DA-1 receptors have previously been localized to human left ventricle. METHODS: Twenty-six American Society of Anaesthesiology class 2-3 elective coronary artery bypass graft patients who did not require inotropic support on separation from cardiopulmonary bypass (CPB) were studied. According to a randomized allocation patients received either dopexamine (1 microg\\/kg per min) or placebo (saline) by intravenous infusion for 15 min. Immediately prior to and at 5,10 and 15 min of infusion, blood flow through the internal mammary and vein grafts (Transit time flow probes, Transonic Ltd.), heart rate, cardiac index, mean arterial pressure and pulmonary haemodynamics were noted. The data were analysed using multivariate analysis of variance. RESULTS: Low-dose dopexamine (1 microg\\/kg per min) caused a significant increase in mammary graft blood flow compared to placebo at 15 min of infusion (P=0.028, dopexamine group left internal mammary artery (LIMA) flow of 43.3+\\/-14.2 ml\\/min, placebo group LIMA flow at 26.1+\\/-16.3 ml\\/min). Dopexamine recipients demonstrated a non-significant trend to increased saphenous vein graft flow (P=0.059). Increased heart rate was the only haemodynamic change induced by dopexamine (P=0.004, dopexamine group at 85.2+\\/-9.6 beats\\/min and placebo group at 71.1+\\/-7.6 beats\\/min after 15 min of infusion). CONCLUSION: This study demonstrates that administration of dopexamine (1 microg\\/kg per min) was associated with a significant increase in internal mammary artery graft blood flow with mild increase in heart rate being the only haemodynamic change. Low-dose dopexamine may

  4. Computed tomography arterial portography for assessment of portal vein injury after blunt hepatic trauma.

    Science.gov (United States)

    Fu, Chen Ju; Wong, Yon Cheong; Tsang, Yuk Ming; Wang, Li Jen; Chen, Huan Wu; Ku, Yi Kang; Wu, Cheng Hsien; Chen, Huan Wen; Kang, Shih Ching

    2015-01-01

    Intrahepatic portal vein injuries secondary to blunt abdominal trauma are difficult to diagnose and can result in insidious bleeding. We aimed to compare computed tomography arterial portography (CTAP), reperfusion CTAP (rCTAP), and conventional computed tomography (CT) for diagnosing portal vein injuries after blunt hepatic trauma. Patients with blunt hepatic trauma, who were eligible for nonoperative management, underwent CTAP, rCTAP, and CT. The number and size of perfusion defects observed using the three methods were compared. A total of 13 patients (seven males/six females) with a mean age of 34.5±14.1 years were included in the study. A total of 36 hepatic segments had perfusion defects on rCTAP and CT, while there were 47 hepatic segments with perfusion defects on CTAP. The size of perfusion defects on CT (239 cm3; interquartile range [IQR]: 129.5, 309.5) and rCTAP (238 cm3; IQR: 129.5, 310.5) were significantly smaller compared with CTAP (291 cm3; IQR: 136, 371) (both, P = 0.002). Perfusion defects measured by CTAP were significantly greater than those determined by either rCTAP or CT in cases of blunt hepatic trauma. This finding suggests that CTAP is superior to rCTAP and CT in evaluating portal vein injuries after blunt liver trauma.

  5. Determination of hepatic fractional clearance of radioactive gold colloids for a measure of effective hepatic blood flow

    International Nuclear Information System (INIS)

    Fujii, Masahiro

    1979-01-01

    For a measure of effective blood flow, a hepatic fractional clearance of 198 Au-colloids was determined, which was obtained from the disappearance rate multiplied by the fraction of injected dose taken up by the liver. The hepatic uptake was determined with a gamma camera. The counts over the liver was corrected for body weight and height. The method was considered sufficiently simple for routine use. 198 Au-colloids were obtained from Dainabot Lab. and CIS. The former gave 64% higher values of disappearance rate than the latter, without any change in the organ distribution. A quality control tests were applied over a six-year period to the disappearance rates. Reproducibility within 95 to confidence limits was found for both groups. In 28 normal control subjects, hepatic fractional clearance of the colloids from Dainabot Lab. was 18.5 +- 3.4%/min. In patients with progressed hepatic disease, both hepatic fractional clearance and final hepatic uptake were decreased, showing that the determination of hepatic uptake is necessary in measuring effective hepatic blood flow by the colloidal clearance method. The influence of splenic uptake is discussed in relation to hepatic blood flow measurement. (author)

  6. Multidetector computed tomography angiography of the celiac trunk and hepatic arterial system: normal anatomy and main variants

    Energy Technology Data Exchange (ETDEWEB)

    Araujo-Neto, Severino Aires; Mello-Junior, Carlos Fernando de; Franca, Henrique Almeida; Duarte, Claudia Martina Araujo; Borges, Rafael Farias; Magalhaes, Ana Guardiana Ximenes de, E-mail: severinoaires@hotmail.com [Universidade Federal da Paraiba (UFPB), Joao Pessoa, PB (Brazil)

    2016-01-15

    Although digital angiography remains as the gold standard for imaging the celiac arterial trunk and hepatic arteries, multidetector computed tomography in association with digital images processing by software resources represents a useful tool particularly attractive for its non invasiveness. Knowledge of normal anatomy as well as of its variations is helpful in images interpretation and to address surgical planning on a case-by-case basis. The present essay illustrates several types of anatomical variations of celiac trunk, hepatic artery and its main branches, by means of digitally reconstructed computed tomography images, correlating their prevalence in the population with surgical implications. (author)

  7. Peripheral Blood Lymphocyte Depletion After Hepatic Arterial {sup 90}Yttrium Microsphere Therapy for Hepatocellular Carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Carr, Brian I., E-mail: brianicarr@hotmail.com [Department of Surgery, University of Pittsburgh Medical Center, Pittsburgh, PA and Department of Nutrition and Exptl Biology, Saverio De Bellis Medical Research Institute, Castellana Grotte, Bari (Italy); Metes, Diana M. [Department of Surgery, University of Pittsburgh Medical Center, Pittsburgh, PA and Department of Nutrition and Exptl Biology, Saverio De Bellis Medical Research Institute, Castellana Grotte, Bari (Italy)

    2012-03-01

    Purpose: The short- and long-term effects of {sup 90}Yttrium microspheres therapy for hepatocellular carcinoma (HCC) on peripheral blood lymphocytes are unknown and were therefore examined. Methods and Materials: Ninety-two HCC patients were enrolled in a {sup 90}Yttrium therapy study and routine blood counts were examined as part of standard clinical monitoring. Results: We found an early, profound, and prolonged lymphopenia. In a subsequent cohort of 25 additional HCC patients, prospective flow cytometric immune-monitoring analysis was performed to identify specific changes on distinct lymphocyte subsets (i.e., CD3, CD4, CD8 T, and CD19 B lymphocytes) and NK cells absolute numbers, in addition to the granulocytes and platelets subsets. We found that the pretreatment lymphocyte subset absolute numbers (with the exception of NK cells) had a tendency to be lower compared with healthy control values, but no significant differences were detected between groups. Posttherapy follow-up revealed that overall, all lymphocyte subsets, except for NK cells, were significantly (>50% from pretherapy values), promptly (as early as 24 h) and persistently (up to 30 months) depleted post-{sup 90}Yttrium microspheres therapy. In contrast, granulocytes increased rapidly (24 h) to compensate for lymphocyte depletion, and remained increased at 1-year after therapy. We further stratified patients into two groups, according to survival at 1 year. We found that lack of recovery of CD19, CD3, CD8, and especially CD4 T cells was linked to poor patient survival. No fungal or bacterial infections were noted during the 30-month follow-up period. Conclusions: The results show that lymphocytes (and not granulocytes, platelets, or NK cells) are sensitive to hepatic arterial {sup 90}Yttrium without associated clinical toxicity, and lack of lymphocyte recovery (possibly leading to dysregulation of adaptive cellular immunity) posttherapy indicates poor survival.

  8. Percutaneous and Endovascular Embolization of Ruptured Hepatic Artery Aneurysm

    International Nuclear Information System (INIS)

    Little, Andrew F.; Lee, Wai Kit

    2002-01-01

    A 72-year-old woman presented with an intraperitoneal hemorrhage from a ruptured intrahepatic arteryaneurysm, with an associated pseudoaneurysm developing a high-flow arteriovenous fistula. Persistent coagulopathy and a median arcuate ligament stenosis of the celiac axis further complicated endovascular management. Aneurysm thrombosis required percutaneous embolization with coils, a removable core guidewire and polyvinyl alcohol particles

  9. The effect of partial portal decompression on portal blood flow and effective hepatic blood flow in man: a prospective study.

    Science.gov (United States)

    Rosemurgy, A S; McAllister, E W; Godellas, C V; Goode, S E; Albrink, M H; Fabri, P J

    1995-12-01

    With the advent of transjugular intrahepatic porta-systemic stent shunt and the wider application of the surgically placed small diameter prosthetic H-graft portacaval shunt (HGPCS), partial portal decompression in the treatment of portal hypertension has received increased attention. The clinical results supporting the use of partial portal decompression are its low incidence of variceal rehemorrhage due to decreased portal pressures and its low rate of hepatic failure, possibly due to maintenance of blood flow to the liver. Surprisingly, nothing is known about changes in portal hemodynamics and effective hepatic blood flow following partial portal decompression. To prospectively evaluate changes in portal hemodynamics and effective hepatic blood flow brought about by partial portal decompression, the following were determined in seven patients undergoing HGPCS: intraoperative pre- and postshunt portal vein pressures and portal vein-inferior vena cava pressure gradients, intraoperative pre- and postshunt portal vein flow, and pre- and postoperative effective hepatic blood flow. With HGPCS, portal vein pressures and portal vein-inferior vena cava pressure gradients decreased significantly, although portal pressures remained above normal. In contrast to the significant decreases in portal pressures, portal vein blood flow and effective hepatic blood flow do not decrease significantly. Changes in portal vein pressures and portal vein-inferior vena cava pressure gradients are great when compared to changes in portal vein flow and effective hepatic blood flow. Reduction of portal hypertension with concomitant maintenance of hepatic blood flow may explain why hepatic dysfunction is avoided following partial portal decompression.

  10. Parameters of Blood Flow in Great Arteries in Hypertensive ISIAH Rats with Stress-Dependent Arterial Hypertension.

    Science.gov (United States)

    Seryapina, A A; Shevelev, O B; Moshkin, M P; Markel', A L

    2016-08-01

    Magnetic resonance angiography was used to examine blood flow in great arteries of hypertensive ISIAH and normotensive Wistar rats. In hypertensive ISIAH rats, increased vascular resistance in the basin of the abdominal aorta and renal arteries as well as reduced fraction of total renal blood flow were found. In contrast, blood flow through both carotid arteries in ISIAH rats was enhanced, which in suggests more intensive blood supply to brain regulatory centers providing enhanced stress reactivity of these rats characterized by stress-dependent arterial hypertension.

  11. Transcatheter Arterial Chemoembolization Based on Hepatic Hemodynamics for Hepatocellular Carcinoma

    Directory of Open Access Journals (Sweden)

    Satoru Murata

    2013-01-01

    Full Text Available Hepatocellular carcinoma (HCC is the sixth most common cancer and the third leading cause of cancer-related deaths in the world. The Barcelona Clinic Liver Cancer (BCLC classification has recently emerged as the standard classification system for clinical management of patients with HCC. According to the BCLC staging system, curative therapies (resection, transplantation, and percutaneous ablation can improve survival in HCC patients diagnosed at an early stage and offer potential long-term curative effects. Patients with intermediate-stage HCC benefit from transcatheter arterial chemoembolization (TACE, and those diagnosed at an advanced stage receive sorafenib, a multikinase inhibitor, or conservative therapy. Most patients receive palliative or conservative therapy only, and approximately 50% of patients with HCC are candidates for systemic therapy. TACE is often recommended for advanced-stage HCC patients all over the world because these patients desire therapy that is more effective than systemic chemotherapy or conservative treatment. This paper aims to summarize both the published data and important ongoing studies for TACE and to discuss technical improvements in TACE for advanced-stage HCC.

  12. Middle cerebral artery flow velocity waveforms in fetal hypoxaemia.

    Science.gov (United States)

    Vyas, S; Nicolaides, K H; Bower, S; Campbell, S

    1990-09-01

    In 81 small-for-gestational age fetuses (SGA) colour flow imaging was used to identify the fetal middle cerebral artery for subsequent pulsed Doppler studies. Impedence to flow (pulsatility index; PI) was significantly lower, and mean blood velocity was significantly higher, than the respective reference ranges with gestation. Fetal blood sampling by cordocentesis was performed in all SGA fetuses and a significant quadratic relation was found between fetal hypoxaemia and the degree of reduction in the PI of FVWs from the fetal middle cerebral artery. Thus, maximum reduction in PI is reached when the fetal PO2 is 2-4 SD below the normal mean for gestation. When the oxygen deficit is greater there is a tendency for the PI to rise, and this presumably reflects the development of brain oedema.

  13. Hepatic Arterial Perfusion Scintigraphy with '99mTc-Macroaggregated Albumin in Hepatocellular Carcinoma

    International Nuclear Information System (INIS)

    Kim, Gang Deuk; Sohn, Kwang Joon; Min, Kyung Yoon; Kwon, Young Mi; Kim, Chang Guhn; Noh, Byung Suk; Won, Jong Jin

    1994-01-01

    Hepatic arterial perfusion scintigraphy with '9 9m Tc macroggregated albumin (HAPS) study was carried out in 16 patients with hepatocellular carcinoma (HCC) and in six patients without liver tumor to evaluate HAPS findings of hepatocellular carcinoma and use fullness of HAPS. HAPS with planar and SPECT study were performed in 22 patients after conventional hepatic or celiac arteriography. For HAPS study, 4 5 mCi of MAA mixed with 2 ml of saline was injected into proper hepatic artery or its distal branches at the rate of approximately 1 ml/sec. We analysed 21 HCCs over 2 cm in diameter(average diameter: 6.4 cm) and 17 of 21 HCCs were over 4 cm in diameter. CT, sonography and angiography were performed within two week in all 16 patients and liver scan was performed in 12 patients. Three different pattern of tumor perfusion were observed in 16 patients with HCC. 1) diffuse increased perfusion in 16 of 21(76%) 2) increased peripheral perfusion in 4 of 21(19%) 3) diffuse decreased perfusion in 1 of 21 (5%) Arteriovenous shunt indicated by lung uptake of MAA were observed in 9 of 16 (56% ). In contrast, angiography demonstrates arteriovenous shunt in 2 of 16 (13%). There was no accumulation of radioactivity on RRC blood pool scan in all six patients with HCC examined. HAPS is useful study in evaluation of perfusion pattern or vascularity of HCC and in detection of arteriovenous shunt.

  14. Ultrasonic Doppler measurement of renal artery blood flow

    Science.gov (United States)

    Freund, W. R.; Meindl, J. D.

    1975-01-01

    An extensive evaluation of the practical and theoretical limitations encountered in the use of totally implantable CW Doppler flowmeters is provided. Theoretical analyses, computer models, in-vitro and in-vivo calibration studies describe the sources and magnitudes of potential errors in the measurement of blood flow through the renal artery, as well as larger vessels in the circulatory system. The evaluation of new flowmeter/transducer systems and their use in physiological investigations is reported.

  15. Abnormal arterial flows by a distributed model of the fetal circulation.

    Science.gov (United States)

    van den Wijngaard, Jeroen P H M; Westerhof, Berend E; Faber, Dirk J; Ramsay, Margaret M; Westerhof, Nico; van Gemert, Martin J C

    2006-11-01

    Modeling the propagation of blood pressure and flow along the fetoplacental arterial tree may improve interpretation of abnormal flow velocity waveforms in fetuses. The current models, however, either do not include a wide range of gestational ages or do not account for variation in anatomical, vascular, or rheological parameters. We developed a mathematical model of the pulsating fetoumbilical arterial circulation using Womersley's oscillatory flow theory and viscoelastic arterial wall properties. Arterial flow waves are calculated at different arterial locations from which the pulsatility index (PI) can be determined. We varied blood viscosity, placental and brain resistances, placental compliance, heart rate, stiffness of the arterial wall, and length of the umbilical arteries. The PI increases in the umbilical artery and decreases in the cerebral arteries, as a result of increasing placental resistance or decreasing brain resistance. Both changes in resistance decrease the flow through the placenta. An increased arterial stiffness increases the PIs in the entire fetoplacental circulation. Blood viscosity and peripheral bed compliance have limited influence on the flow profiles. Bradycardia and tachycardia increase and decrease the PI in all arteries, respectively. Umbilical arterial length has limited influence on the PI but affects the mean arterial pressure at the placental cord insertion. The model may improve the interpretation of arterial flow pulsations and thus may advance both the understanding of pathophysiological processes and clinical management.

  16. Measurement of Blood Flow in an Intracranial Artery Bypass From the Internal Maxillary Artery by Intraoperative Duplex Sonography.

    Science.gov (United States)

    Yu, Zaitao; Shi, Xiang'en; Brohi, Shams Raza; Qian, Hai; Liu, Fangjun; Yang, Yang

    2017-02-01

    This study explored the hemodynamic characteristics of a subcranial-intracranial bypass from the internal maxillary artery by measuring blood flow on intraoperative duplex sonography. The hemodynamic parameters of the internal maxillary artery (n = 20), radial artery (n = 20), internal maxillary artery-middle cerebral artery bypass (n = 42), and internal maxillary artery-posterior cerebral artery bypass (n = 9) were measured by intraoperative duplex sonography. There was no significant difference in the internal diameters of the internal maxillary and radial arteries (mean ± SD, 2.51 ± 0.34 versus 2.56 ± 0.22 mm; P = .648). The mean radial artery graft length for subcranial-intracranial bypasses was 88.5 ± 12.78 mm (95% confidence interval [CI], 80.8-90.2 mm). Internal maxillary artery-middle cerebral artery bypasses required a shorter radial artery graft than internal maxillary artery-posterior cerebral artery bypasses (77.8 ± 2.47 versus 104.8 ± 4.77 mm; P = .001). The mean flow volumes were 85.3 ± 18.5 mL/min (95% CI, 76.6-93.9 mL/min) for the internal maxillary artery, 72.6 ± 26.4 mL/min (95% CI, 64.3-80.9 mL/min) for internal maxillary artery-middle cerebral artery bypasses, and 45.4 ± 6.7 mL/min (95% CI, 40.7-50.0 mL/min) for internal maxillary artery-posterior cerebral artery bypasses. All grafts were opened after the success of the salvage procedures had been established, and the early patency rates (1 month after the operation) were 95% for internal maxillary artery-middle cerebral artery bypasses and 100% the internal maxillary artery-posterior cerebral artery bypasses. Measurement of blood flow by intraoperative sonography can be helpful in decision making and predicting graft patency and success after neurosurgical bypass procedures. © 2016 by the American Institute of Ultrasound in Medicine.

  17. Infusion MR arteriography during hepatic arterial infusion chemotherapy. Evaluation of clinical usefulness

    International Nuclear Information System (INIS)

    Uchino, Minako; Takizawa, Kenji

    2003-01-01

    We developed a new method of infusion MR arteriography (IMRA) via an implantable port system using an infusion pump for the evaluation of drug distribution during hepatic arterial infusion chemotherapy. The purposes of this study were to optimize the method and evaluate its clinical usefulness. We used 3D-T1 turbo field echo (TFE) as the most suitable sequence for IMRA according to the results of a phantom model experiment. We examined 33 cases of liver cancer that had been treated by arterial infusion chemotherapy via the port system. The following investigations were performed: degree of tumor enhancement, intra- and extra- hepatic perfusion abnormality, and related toxicity. The evaluation of images was performed separately by two radiologists. IMRA provided good images of contrast enhancement, to reveal the perfusion patterns. The treatment response rate in the tumor group with well enhancement was higher than that of the group with poor enhancement (p<0.0001). Extrahepatic perfusion was well visualized and was correlated with toxicity (p<0.0001). IMRA is a useful method to evaluate drug perfusion for the optimization of arterial infusion chemotherapy. (author)

  18. Study of the additional filter in transcatheter hepatic arterial embolization

    International Nuclear Information System (INIS)

    Hitomi, Go; Arao, Shinichi; Tomomitsu, Tatsushi

    2010-01-01

    It is well known that Interventional Radiology (IVR) is useful. However, the patient dose in IVR is increasing because of the prolongation of fluoroscopic time and the increase in the number of radiographies in recent years. We studied the adequacy of the additional filter for the decrease of the skin surface dose in patients with hepatocellular carcinoma of transcatheter arterial embolization (TAE). In 20 patients (15 men and 5 women, average age: 66.9 and 72.0 years old) who had undergone TAE, we estimated the skin surface dose from the records of their exposure condition (tube voltage, tube current, time, and field size of image intensifier) and the results of the phantom experiment with 2 kinds of additional filter. The estimated skin surface dose of the patient was 1.75±0.84 with the additional filter of 1.5 mm thickness of aluminum (1.5 mmAl), 1.46±0.67 Gy with 0.03 mm thickness tantalum (0.03 mmTa) and 1.17±0.55 Gy with 0.06 mm thickness of tantalum (0.06 mmTa). Against a skin surface dose of 1.5 mmAl, the dose reduction of 16.7% was shown in 0.03 mmTa and 33.2% in 0.06 mmTa. With a digital subtraction angiography (DSA) phantom of iodine density 0.5 and 1.0 and 2.0 mgI/ml, DSA images were acquisitioned at tube voltage 70, 80 and 90 kV to compare the detectability of contrast media in 0.06 mmTa with 1.5 mmAl. To evaluate the detectability of contrast media in 0.06 mmTa in 1.5 mmAl, receiver operating characteristic (ROC) analysis was performed with the pixel value of the phantom image. The area under the ROC curve in a 1.5 mmAl filter and the 0.06 mmTa filter provided with each contrast media density and each tube voltage was approximately a constant value. It was suggested that there was no differences in the detectability of contrast media in both additional filters. In conclusion, the skin surface dose of the patient was able to be reduced 33.2% without decreasing contrast media detectability by changing the additional filter from 1.5 mmAl to 0.06 mm

  19. FDM Analysis for Blood Flow through Stenosed Tapered Arteries

    Directory of Open Access Journals (Sweden)

    Sankar DS

    2010-01-01

    Full Text Available Abstract A computational model is developed to analyze the unsteady flow of blood through stenosed tapered narrow arteries, treating blood as a two-fluid model with the suspension of all the erythrocytes in the core region as Herschel-Bulkley fluid and the plasma in the peripheral layer as Newtonian fluid. The finite difference method is employed to solve the resulting system of nonlinear partial differential equations. The effects of stenosis height, peripheral layer thickness, yield stress, viscosity ratio, angle of tapering and power law index on the velocity, wall shear stress, flow rate and the longitudinal impedance are analyzed. It is found that the velocity and flow rate increase with the increase of the peripheral layer thickness and decrease with the increase of the angle of tapering and depth of the stenosis. It is observed that the flow rate decreases nonlinearly with the increase of the viscosity ratio and yield stress. The estimates of the increase in the longitudinal impedance to flow are considerably lower for the two-fluid Herschel-Bulkley model compared with those of the single-fluid Herschel-Bulkley model. Hence, it is concluded that the presence of the peripheral layer helps in the functioning of the diseased arterial system.

  20. Significance of diagnosis of liver metastases from colorectal cancer by angio helical CT and intermittent hepatic arterial infusion chemotherapy after hepatic resection in terms of prognosis

    International Nuclear Information System (INIS)

    Hatsuse, Kazuo; Aoki, Hideki; Murayama, Michinori

    1997-01-01

    Seventy five cases had undergone hepatic resection for liver metastases from colorectal cancer from 1979 to 1994. Computed tomography during hepatic angiography (angio CT) was tried in 27 cases. At first, we compared detection ratios of angio CT for liver metastase to those of ultrasonography, conventional CT, and operative ultrasonography on these 27 cases. Next, the prognosis of seventy five cases was examined. They were divided into three groups; the HX group 29 cases with only hepatic resection; the HX+AP group of 19 cases with intermittent hepatic arterial infusion chemotherapy after hepatic resection; the angio CT group of 27 cases selected for hepatic resection by angio CT, followed by the same infusion chemotherapy as that given to the HX+AP group. Fifty metastases were diagnosed histopathologically in twenty seven cases that underwent hepatic resection after angio CT. Detection ratios for small metastases 1.0 cm or smaller in diameter were 8.3% with ultrasonography, 25% with CT, 75% with angio CT, and 50% with operative ultrasonography. Detection ratios of angio CT were superior to those of ultrasonography and CT. Recurrence rates of the remnant liver were significantly low and survival rates were significantly superior in the angio CT group compared to the other two groups (p<0.02). The prognosis with and without intermittent hepatic arterial infusion chemotherapy after hepatic resection were significantly different (p<0.03). The above data suggest that improvement of detection ratios for liver metastases by angio CT, and probably concomitant intermittent hepatic infusion chemotherapy contribute to decreased remnant liver recurrence and an increased survival rate. (author)

  1. Endovascular Mechanical Thromboaspiration of Right Hepatic Arterial Thrombosis After Liver Transplantation

    International Nuclear Information System (INIS)

    Gandini, Roberto; Konda, Daniel; Toti, Luca; Abrignani, Sergio; Merolla, Stefano; Tisone, Giuseppe; Floris, Roberto

    2017-01-01

    A 56-year-old male Patient presented 27 days after a liver transplantation (LT) with fever and hyperbilirubinemia. He underwent CT examination resulting in a diagnosis of right hepatic artery (HA) occlusion with hepatic bilomas. Once placed a long right femoral 6F introducer at the origin of the HA, a 0.014” guidewire was advanced over the thrombus, in a segmental branch. A 4MAX (Penumbra, Alameda, USA) catheter was advanced and withdrawn under constant aspiration until complete clot removal was achieved. Follow-up CT and D-US assessments at 12 months demonstrated regular HA patency and bilomas reduction. Endovascular thromboaspiration is an effective strategy in cases of E-HAT after LT.

  2. Endovascular Mechanical Thromboaspiration of Right Hepatic Arterial Thrombosis After Liver Transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Gandini, Roberto; Konda, Daniel [University of Rome “Tor Vergata”, Department of Diagnostic Imaging, Molecular Imaging, Interventional Radiology and Radiotherapy, PTV Foundation, “Tor Vergata” Hospital (Italy); Toti, Luca [University of Rome “Tor Vergata”, Department of Surgery, Section of Transplantation, PTV Foundation, “Tor Vergata” Hospital (Italy); Abrignani, Sergio, E-mail: stem83@gmail.com; Merolla, Stefano [University of Rome “Tor Vergata”, Department of Diagnostic Imaging, Molecular Imaging, Interventional Radiology and Radiotherapy, PTV Foundation, “Tor Vergata” Hospital (Italy); Tisone, Giuseppe [University of Rome “Tor Vergata”, Department of Surgery, Section of Transplantation, PTV Foundation, “Tor Vergata” Hospital (Italy); Floris, Roberto [University of Rome “Tor Vergata”, Department of Diagnostic Imaging, Molecular Imaging, Interventional Radiology and Radiotherapy, PTV Foundation, “Tor Vergata” Hospital (Italy)

    2017-04-15

    A 56-year-old male Patient presented 27 days after a liver transplantation (LT) with fever and hyperbilirubinemia. He underwent CT examination resulting in a diagnosis of right hepatic artery (HA) occlusion with hepatic bilomas. Once placed a long right femoral 6F introducer at the origin of the HA, a 0.014” guidewire was advanced over the thrombus, in a segmental branch. A 4MAX (Penumbra, Alameda, USA) catheter was advanced and withdrawn under constant aspiration until complete clot removal was achieved. Follow-up CT and D-US assessments at 12 months demonstrated regular HA patency and bilomas reduction. Endovascular thromboaspiration is an effective strategy in cases of E-HAT after LT.

  3. Anatomical variants of celiac trunk, hepatic and renal arteries in a population of developing country using multidetector computed tomography angiography

    International Nuclear Information System (INIS)

    Arifuzzaman, M.; Naqvi, S.S.N.; Rasool, M.; Hussain, M.

    2017-01-01

    Background: Multidetector Computed Tomography (MDCT)s has become a major part in evaluation of hepatic and renal tumours. With improvements in MDCT, CT angiography has also improved and normal anatomy and its variants in patients undergoing operative or interventional procedures can be effectively studied. The purpose of this study was to evaluate the frequency of anatomical variation of celiac trunk, hepatic and renal arterial systems in patients undergoing multidetector CT (MDCT) angiography of the abdominal aorta. Methods: A descriptive, retrospective cross-sectional study was carried out on CT angiographies performed during the months of October till December 2015. Hepatic and renal arteries and celiac trunk were studied and normal and anatomical variations were noted. All patients with abnormalities affecting the vessels or a history of any vascular abnormality were excluded from the study. Results: Out of total 110 patients, 69.1% had normal and 30.9% had variant hepatic artery with Michel Type IV being the most common variant whereas 88.2% had normal celiac trunk and 8.2% had gastrosplenic trunk variant. Variation in renal arterial system was observed in 15.5% of the patients with two renal arteries on right and two on left being the most common type. Multiple variants were identified in 11.8% of the patients. Conclusion: The type and knowledge of anatomy is of prime importance for an optimum preoperative planning in surgical or radiological procedure. MDCT allows minimally invasive assessment of arterial anatomy with high quality 3D reconstruction images. (author)

  4. Hepatic blood flow determination. A comparison of 99mTc-diethyl-IDA and indocyanine green as hepatic blood flow indicators in man

    DEFF Research Database (Denmark)

    Henriksen, Jens Henrik Sahl; Winkler, K

    1987-01-01

    99mTc-diethyl-acetanilide-iminodiacetic acid (IDA) was compared with indocyanine green (ICG) as an indicator of hepatic blood flow (HBF). Twelve subjects (8 with cirrhosis, 2 with fatty liver, one with pancreatitis, and one with intestinal angina) were studied during hepatic vein catheterization...

  5. Value of Micronester coils in port-catheter implantation for continuous hepatic arterial infusion chemotherapy with fixed catheter tip method

    International Nuclear Information System (INIS)

    Yamagami, Takuji; Kato, Takeharu; Hirota, Tatsuya; Yoshimatsu, Rika; Matsumoto, Tomohiro; Nishimura, Tsunehiko; White, Robert I.

    2008-01-01

    To retrospectively evaluate the use of Micronester coils in port-catheter implantation with the fixed catheter tip method in comparison with other previously used coils. The cohort of this study was 143 consecutive patients with unresectable advanced liver cancer for whom a port-catheter system was percutaneously implanted. In the most recent 32 patients, Micronester coils were used for catheter tip fixation. Details of embolic agents for fixation, persistent blood flow beyond the distal end of the indwelling catheter, and complications were compared between cases without and with Micronester coils. In all, percutaneous port-catheter placement was successful. Mean number of coils used for fixation was 4.2 without Micronester coils vs. 2.5 with Micronester coils. N-butyl cyanoacrylate (NBCA)-Lipiodol was additionally used for catheter tip fixation in 85.6% of 111 procedures without Micronester coils and in 50% of 32 using Micronester coils. The gastroduodenal artery beyond the distal end was not detected at the final examination after any procedure. Catheter dislocation occurred in five and hepatic arterial obstruction or severe stenosis in eight. The number of coils used and necessity of NBCA-Lipiodol could be decreased with usage of Micronester coils without decreasing fixation ability compared to other coils. (orig.)

  6. Pulmonary scanning: quantitative evaluation of pulmonary arterial flow

    Energy Technology Data Exchange (ETDEWEB)

    Papaleo Netto, M; Fujioka, T [Sao Paulo Univ. (Brazil). Faculdade de Medicina; Dias Neto, A; Carvalho, N [Sao Paulo Univ. (Brazil). Centro de Medicina Nuclear

    1974-01-01

    From ten normal subjects of both sexes, the quantitative regional blood flow of the pulmonary artery was evaluated using scanning with macroaggregated radio-iodinated (/sup 131/I) albumin. It was possible to conclude that: the digital recording of data (counts/cm/sup 2/), from any particular area of interest, is the best method for this evaluation; the lung, even being a thick organ, can be well studied by quantitative scanning, since its structure doesn't hinder the passage of radiations because it is covered only by the thoracic wall; scanning can be used to evaluate regional perfusion of the pulmonary artery, based on the proportionality between density of aggregates and blood flux in the different areas; the concentration of macroaggregates on the lung's superior section never reaches more than 40% of the radioactivity of the whole lung; there is no significant difference between left and right lungs, concerning the relationship between radioactivity on the superior section and the total area and quantitative analysis of pulmonary artery flow by means of scanning is a possible, reliable, and safe technique, without distress for the patient.

  7. Pulmonary scanning: quantitative evaluation of pulmonary arterial flow

    International Nuclear Information System (INIS)

    Papaleo Netto, M.; Fujioka, T.; Dias Neto, A.; Carvalho, N.

    1974-01-01

    From ten normal subjects of both sexes, the quantitative regional blood flow of the pulmonary artery was evaluated using scanning with macroaggregated radio-iodinated ( 131 I) albumin. It was possible to conclude that: the digital recording of data (counts/cm 2 ), from any particular area of interest, is the best method for this evaluation; the lung, even being a thick organ, can be well studied by quantitative scanning, since its structure doesn't hinder the passage of radiations because it is covered only by the thoracic wall; scanning can be used to evaluate regional perfusion of the pulmonary artery, based on the proportionality between density of aggregates and blood flux in the different areas; the concentration of macroaggregates on the lung's superior section never reaches more than 40% of the radioactivity of the whole lung; there is no significant difference between left and right lungs, concerning the relationship between radioactivity on the superior section and the total area and quantitative analysis of pulmonary artery flow by means of scanning is a possible, reliable and safe technique, without distress for the patient [pt

  8. Measurement of hepatic volume and effective blood flow with radioactive colloids: Evaluation of development in liver diseases

    International Nuclear Information System (INIS)

    Fujii, M.; Uchino, H.; Kyoto Univ.

    1982-01-01

    Changes in hepatic volume and the blood flow effectively perfusing the liver parenchyma were studied as an assessment of the severity of liver diseases. Hepatic effective blood flow was estimated as the hepatic fractional clearance of radioactive colloids, obtained from the disappearance rate multiplied by the fraction of injected dose taken up by the liver. The hepatic fractional clearance was normal or not markedly decreased in patients with acute hepatitis which had developed favorably, but was severely decreased in patients with fulminant hepatitis. In liver diseases, the ratio of hepatic volume to fractional clearance was found to increase as the clearance decreased. In subjects with normal clearance, hepatic fractional clearance was correlated significantly with liver volume, indicating that hepatic effective blood flow is proportional to parenchymal volume in an unanesthetized, resting state. In biopsied cases changes in volume and blood flow accorded well with changes indicated by morphological criteria. In chronic persistent hepatitis, effective hepatic blood flow is not diminished. However, hepatic blood flow were observed between the cirrhosis or chronic aggressive hepatitis, and normal control groups. Extension of chronic inflammatory infiltration into the parenchyma distinguishes chronic aggressive hepatitis from chronic persistent hepatitis. Architecture is often disturbed in the former. These changes should be accompanied by disturbance of microcirculation. The present study indicates that the decrease in effective hepatic blood flow in chronic hepatitis and cirrhosis has two aspects: one is a summation of microcirculatory disturbances, and the other is a decrease in liver cell mass. (orig.)

  9. Rare Type of Course and Distribution of an Additional Right Hepatic Artery: A Possible Source of Iatrogenic Injury During Hepato-biliary and Pancreatic Surgeries

    Directory of Open Access Journals (Sweden)

    Prakashchandra Shetty

    2017-07-01

    Full Text Available Celiac artery shows frequent variations in its branching pattern. Knowledge of its possible variations is useful in gastric, pancreatic and hepato-biliary surgeries. During our dissection classes, we observed a rare variation of the branching pattern of celiac trunk. It divided normally into its three branches; left gastric, splenic and common hepatic arteries. Left gastric and splenic arteries were normal in their course and distribution. The common hepatic artery trifurcated to give hepatic artery proper, gastroduodenal artery and an additional right hepatic artery. The branching pattern of hepatic artery proper and gastroduodenal arteries was normal. The additional right hepatic artery gave origin to a right gastric artery and a large pancreatic branch to the head of the pancreas. It coursed parallel to the bile duct, being on its right side, passed through the Calot’s triangle and entered the right lobe of liver through the fossa for gall bladder. In the Calot’s triangle, it gave a cystic branch to the gall bladder. We discuss the clinical importance of this rare variation in this paper.

  10. The Main Anatomic Variations of the Hepatic Artery and Their Importance in Surgical Practice: Review of the Literature.

    Science.gov (United States)

    Noussios, George; Dimitriou, Ioannis; Chatzis, Iosif; Katsourakis, Anastasios

    2017-04-01

    Anatomical variations of the hepatic artery are important in the planning and performance of abdominal surgical procedures. Normal hepatic anatomy occurs in approximately 80% of cases, for the remaining 20% multiple variations have been described. The purpose of this study was to review the existing literature on the hepatic anatomy and to stress out its importance in surgical practice. Two main databases were searched for eligible articles during the period 2000 - 2015, and results concerning more than 19,000 patients were included in the study. The most common variation was the replaced right hepatic artery (type III according to Michels classification) which is the chief source of blood supply to the bile duct.

  11. Flow Characteristics Near to Stent Strut Configurations on Femoropopliteal Artery

    Science.gov (United States)

    Paisal, Muhammad Sufyan Amir; Fadhil Syed Adnan, Syed; Taib, Ishkrizat; Ismail, Al Emran; Kamil Abdullah, Mohammad; Nordin, Normayati; Seri, Suzairin Md; Darlis, Nofrizalidris

    2017-08-01

    Femoropopiteal artery stenting is a common procedure suggested by medical expert especially for patient who is diagnosed with severe stenosis. Many researchers reported that the growth of stenosis is significantly related to the geometry of stent strut configuration. The different shapes of stent geometry are presenting the different flow pattern and re-circulation in stented femoropopliteal artery. The blood flow characteristics near to the stent geometry are predicted for the possibility of thrombosis and atherosclerosis to be formed as well as increase the growth of stenosis. Thus, this study aims to determine the flow characteristic near to stent strut configuration based on different hemodynamic parameters. Three dimensional models of stent and simplified femoropopliteal artery are modelled using computer aided design (CAD) software. Three different models of stent shapes; hexagon, circle and rectangle are simulated using computational fluid dynamic (CFD) method. Then, parametric study is implemented to predict the performance of stent due to hemodynamic differences. The hemodynamic parameters considered are pressure, velocity, low wall shear stress (WSSlow) and wall shear stress (WSS). From the observation, flow re-circulation has been formed for all simulated stent models which the proximal region shown the severe vortices. However, rectangular shape of stent strut (Type P3) shows the lowest WSSlow and the highest WSS between the range of 4 dyne/cm2 and 70 dyne/cm2. Stent Type P3 also shows the best hemodynamic stent performance as compare to others. In conclusion, Type P3 has a favourable result in hemodynamic stent performance that predicted less probability of thrombosis and atherosclerosis to be formed as well as reduces the growth of restenosis.

  12. Hilar anatomy of the hepatic artery and surgical procedure for hilar cholangiocarcinoma

    International Nuclear Information System (INIS)

    Uesaka, Katsuhiko; Maeda, Atsuyuki; Kanamoto, Hideyuki; Matsunaga, Kazuya; Yuasa, Ichiro; Okamura, Yukiyasu; Yamaguchi, Shigeki; Bando, Etsuro; Furukawa, Hiroyoshi

    2006-01-01

    This paper describes the examination of findings by multi-detector-row CT (MDCT) and by surgery to obtain the anatomy of hilar arteries and portal vein, which is necessary for the procedure in the title. Subjects are those findings of 38 patients with hilar cholangiocarcinoma, who underwent its excision during the period of 1 year from 2002 Nov. Before operation, MDCT with 16-row detector was done 20-120 sec after infusion of a non-ionized contrast medium to compose the 3D images. The left hepatic arterial system was found to be classifiable in 3 types of common, anti-clockwise and clockwise one with the respective frequency of 63, 24 and 11%, and the right system, infra-portal (76%) and supra-portal (24%) types. It was concluded that to the arterial clockwise and supra-portal types, particular attention should be paid for the cancer invasion there and for avoidance of the artery damage during the operation. (T.I.)

  13. Patent hepatic falciform artery detected after Tc-99m-macroaggregated albumin injection on SPECT/CT prior to Yttrium-90 microsphere radioembolization: a case report

    International Nuclear Information System (INIS)

    Karaman, B.; Aslan, A.; Hamcan, S.; Ugurel, M.

    2012-01-01

    Full text: Introduction: Yttrium-90 (Y-90) microsphere radioembolization is increasingly used for the treatment of unresectable hepatocellular carcinoma and liver metastasis. Objectives and tasks: We aim to present the upper abdominal wall skin involvement detected during routine pre-therapy Technetium-99m-macroaggregated albumin (Tc-99m-MAA) on SPECT/CT due to patent hepatic falciform artery and the precautions to avoid this potential complication. Material and methods: 38-year-old male with colon cancer and multiple liver metastasis was evaluated prior to radioembolization and Tc-99 MAA was slowly hand injected at the bifurcation of the proper hepatic artery. Then, the SPECT/CT scan was performed in order to investigate the systemic shunt or gastric involvement. Results: On SPECT/CT scan, involvement of the upper abdominal wall through falciform ligament was seen. Re-evaluation of the hepatic angiogram identified a patent hepatic falciform artery arising from the left hepatic artery. Y-90 microspheres were slowly hand injected to the left hepatic artery superselectively and no extra-hepatic activity was seen on SPECT/CT scan. Conclusion: Upper abdominal pain and dermatitis are uncommon findings after radioembolization and may occur due to inadvertent delivery of Y-90 microspheres into patent hepatic falciform artery. To prevent these complications, either patent hepatic falciform artery must be embolized by coil or Y-90 injection must be performed superselectively

  14. Transplantation of autologous bone marrow stem cells via hepatic artery for the treatment of acute hepatic injury: an experimental study in rabbits

    International Nuclear Information System (INIS)

    Zhu Yinghe; Han Jinling; Liu Yanping; Gao Jue; Xu Ke; Zhang Xitong; Ding Guomin

    2009-01-01

    Objective: To evaluate the transplantation of autologous bone marrow stem cells via hepatic artery in treating acute hepatic injury in experimental rabbit models and to clarify the synergistic effect of hepatocyte growth-promoting factor (pHGF) in stem cell transplantation therapy for liver injury. Methods Acute hepatic injury models were established in 15 experimental rabbits by daily subcutaneous injection of CCl 4 olive oil solution with the dose of 0.8 ml/kg for 4 days in succession. The experimental rabbits were randomly and equally divided into three groups: study group A (stem cell transplant, n = 5), study group B (stem cell transplant + pFHG, n = 5), and control group (n = 5). Bone marrow of 5 ml was drawn from the tibia in all rabbits of both study groups, from which bone marrow stem cells were isolated by using density gradient centrifugation, and 5 ml cellular suspension was prepared. Under fluoroscopic guidance, catheterization through the femoral artery was performed and the cellular suspension was infused into the liver via the hepatic artery. Only injection of saline was carried out in the rabbits of control group. For the rabbits in group B, pFHG (2.0 mg/kg) was administered intravenously every other day for 20 days. At 2, 4 and 8 weeks after stem cell transplantation, hepatic function was determined. Eight weeks after the transplantation all the rabbits were sacrificed and the liver specimens were collected and sent for pathological examination. Results After stem cell transplantation, the hepatic function was gradually improved.Eight weeks after the transplantation, the activity of AST, ALT and the content of ALB, TBIL were significantly lower than that before the procedure, while the content of GOLB was markedly increased in all rabbits. In addition, the difference in the above parameters between three groups was statistically significant (P < 0.05). Pathologically, the hepatocyte degeneration and the fiberous hyperplasia in the study groups

  15. Intraportal nicotine infusion in rats decreases hepatic blood flow through endothelin-1 and both endothelin A and endothelin B receptors

    International Nuclear Information System (INIS)

    Hashimoto, Takashi; Yoneda, Masashi; Shimada, Tadahito; Kurosawa, Mieko; Terano, Akira

    2004-01-01

    Smoking has been demonstrated to aggravate liver injury. Nicotine, a major pharmacological component of tobacco smoke, affects a multitude of functions. Smoking and nicotine induce synthesis of endothelin (ET)-1. The effect of intraportal infusion of nicotine on hepatic circulation and an involvement of ET-1 and ET receptor in the action of nicotine were investigated in rats. Nicotine (0-100 μg/kg/h) was infused into the portal vein of urethane-anesthetized rats, and changes of hepatic blood flow were evaluated. Intraportal infusion of nicotine dose-dependently decreased hepatic blood flow and increased portal pressure without any alteration of heart rate or arterial blood pressure. This action of intraportal nicotine was completely abolished by pretreatment of ET-1 antibody. Either BQ485 (ET A receptor antagonist) or BQ788 (ET B receptor antagonist) partially reversed the effect of nicotine, and combination of BQ788 and BQ485 completely abolished it. These findings suggest that nicotine inhibits hepatic circulation through ET-1, and ET A and ET B receptor

  16. High-Flow Arterio-Hepatic Venous Shunt in Hepatocellular Carcinoma: Use of Multi-Electrode Radiofrequency for Shunt Obliteration

    Energy Technology Data Exchange (ETDEWEB)

    Pua, Uei, E-mail: druei@yahoo.com [Tan Tock Seng Hospital, Department of Diagnostic Radiology (Singapore)

    2015-10-15

    Intra-tumoral arterio-hepatic venous shunting (AHVS) poses an impediment to transarterial chemoembolization of liver tumors. Not only does it present a potential hazard for systemic shunting and embolization, but also the altered flow dynamics may also result in poor delivery of drug/embolics to the target tumor bed. Current available techniques to overcome AVHS include arterial embolization (particles, coils, glue, etc.) or temporary venous occlusion using balloons. We hereby illustrate the use of radiofrequency ablation to obliterate a complex AHVS consisting of a varix-like venous aneurysm.

  17. Relationship between the Direction of Ophthalmic Artery Blood Flow and Ocular Microcirculation before and after Carotid Artery Stenting.

    Science.gov (United States)

    Ishii, Masashi; Hayashi, Morito; Yagi, Fumihiko; Sato, Kenichiro; Tomita, Goji; Iwabuchi, Satoshi

    2016-01-01

    When internal carotid artery stenosis is accompanied by ocular ischemic syndrome, intervention is recommended to prevent irreversible visual loss. In this study, we used laser speckle flowgraphy to measure the ocular microcirculation in the optic nerve head before and after carotid artery stenting (CAS) of 40 advanced internal carotid stenosis lesions from 37 patients. The aim was to investigate the relationship between ocular microcirculation and the direction of ophthalmic artery blood flow obtained by angiography. We found that there was a significant increase in blood flow after CAS ( P = 0.003). Peak systolic velocity as an indicator of the rate of stenosis was also significantly higher in the group with retrograde/undetected flow of the ophthalmic artery than in the group with antegrade flow ( P = 0.002). In all cases where retrograde flow of the ophthalmic artery was observed before stenting, the flow changed to antegrade after stenting. Through the use of laser speckle flowgraphy, this study found that CAS can improve ocular microcirculation. Furthermore, while patients displaying retrograde flow of the ophthalmic artery before stenting have a poor prognosis, CAS corrected the flow to antegrade, suggesting that visual loss can be prevented by improving the ocular microcirculation.

  18. Hilar Inflammatory Pseudotumour with Hepatic Artery Atheroma- mimicker of Klatskin Tumour.

    Science.gov (United States)

    Rastogi, Archana; Bihari, Chhagan; Gupta, Nalini; Deka, Pranjal; Kumar, Arvind; Negi, Sanjay Singh; Arora, Ankur

    2015-03-01

    Inflammatory pseudotumour of hilar biliary structures is an extremely rare benign lesion that can mimic hilar cholangiocarcinoma. Clinical presentation and imaging findings often pose diagnostic difficulties. Main histopathological findings are the presence of myofibroblastic spindle cells, plasma cells, macrophages, and lymphocytes without cellular atypia or atypical mitotic figures. We describe a case of 62 year old male who presented with surgical obstructive jaundice. Imaging revealed a mass lesion involving the biliary confluence with upstream dilatation of biliary tree. Diagnosis of hilar cholangiocarcinoma with type III hilar block was made. Intraoperately hilar mass lesion was found which was encasing right hepatic artery with no evidence of metastasis. The patient underwent Right hepatectomy with caudate lobectomy with complete common bile duct (CBD) excision with Roux en Y hepaticojejunostomy. Unexpectedly histopathological examination showed no evidence of malignancy and revealed hilar inflammatory pseudotumour with hepatic artery atherosclerosis. Preoperative imaging, operative management, pathologic diagnosis and literature review are being presented in view of rarity of the case.

  19. Palonosetron-A Single-Dose Antiemetic Adjunct for Hepatic Artery Radioembolization: A Feasibility Study

    International Nuclear Information System (INIS)

    Siddiqi, Nasir H.; Khan, Atif J.; Devlin, Phillip M.

    2009-01-01

    Nausea and vomiting may occur in a significant minority of patients following hepatic artery embolization with yttrium-90 spheres (K. T. Sato et al. Radiology 247:507-515, 2008). This encumbers human and economic resources and undercuts the assertion that it is as a well-tolerated outpatient treatment. A single intravenous dose of palonosetron HCl was administered before hepatic artery embolization with yttrium-90 spheres to ameliorate posttreatment nausea and vomiting, in 23 consecutive patients. The patients were discharged the day of procedure on oral antiemetics, steroids, and blockers of gastric acid release. All patients had clinical and laboratory evaluation at 2 weeks after the procedure. The data were gathered and reviewed retrospectively. At 2-week follow-up, none reported significant nausea, vomiting, additional antiemetic use, need for parenteral therapy, hospital readmission, or palonosetron-related side effects. All patients recovered from postembolization symptoms within a week after treatment. In conclusion, this retrospective study suggests that single-dose palonosetron is feasible, safe, and effective for acute and delayed nausea and vomiting in this group of patients. The added cost may be offset by benefits.

  20. Intra-Arterial Hepatic Chemotherapy: A Comparison of Percutaneous Versus Surgical Implantation of Port-Catheters

    International Nuclear Information System (INIS)

    Deschamps, F.; Elias, D.; Goere, D.; Malka, D.; Ducreux, M.; Boige, V.; Auperin, A.; Baere, T. de

    2011-01-01

    Purpose: To compare retrospectively the safety and efficacy of percutaneous and surgical implantations of port-catheters for intra-arterial hepatic chemotherapy (IAHC). Materials and Methods: Between January 2004 and December 2008, 126 consecutive patients (mean age 58 years) suffering from liver colorectal metastases were referred for intra-arterial hepatic chemotherapy (IAHC). Port-catheters were percutaneously implanted (P) through femoral access with the patient under conscious sedation when no other surgery was planned or were surgically implanted (S) when laparotomy was performed for another purpose. We report the implantation success rate, primary functionality, functionality after revision, and complications of IAHC. Results: The success rates of implantation were 97% (n = 65 of 67) for P and 98% (n = 58 of 59) for S. One hundred eleven patients received IAHC in our institution (n = 56P and n = 55S). Primary functionality was the same for P and S (4.80 vs. 4.82 courses), but functionality after revision was significantly higher for P (9.18 vs. 5.95 courses, p = 0.004) than for S. Forty-five complications occurred during 516 courses for P and 28 complications occurred during 331 courses for S. The rates of discontinuation of IAHC linked to complications of the port-catheters were 21% (n = 12 of 56) for P and 34% (n = 19 of 55) for S. Conclusion: Overall, significantly better functionality and similar complication rates occurred after P versus S port-catheters.

  1. The effect of ultrasound on arterial blood flow: 1. Steady fully developed flow

    International Nuclear Information System (INIS)

    Bestman, A.R.

    1990-12-01

    The paper models the effects of ultrasound heating of the tissues and the resultant perturbation on blood flow in the arteries and veins. It is assumed that the blood vessel is rigid and the undisturbed flow is fully developed. Acoustical perturbation on this Poiseuille flow, for the general three-dimensional flow with heat transfer in an infinitely long pipe is considered. Closed form analytical solutions are obtained to the problem. It is discovered that the effects of the ultrasound heating are concentrated at the walls of the blood vessels. (author). 4 refs

  2. Hepatic Arterial Chemoembolization Using Drug-Eluting Beads in Gastrointestinal Neuroendocrine Tumor Metastatic to the Liver

    International Nuclear Information System (INIS)

    Gaur, Shantanu K.; Friese, Jeremy L.; Sadow, Cheryl A.; Ayyagari, Rajasekhara; Binkert, Christoph A.; Schenker, Matthew P.; Kulke, Matthew; Baum, Richard

    2011-01-01

    Purpose: This study was designed to evaluate short ( 3 months) follow-up in patients with metastatic neuroendocrine tumor to the liver who underwent hepatic arterial chemoembolization with drug-eluting beads at a single institution. Methods: Institutional review board approval was obtained for this retrospective review. All patients who were treated with 100–300 or 300–500 μm drug-eluting LC Beads (Biocompatibles, UK) preloaded with doxorubicin (range, 50–100 mg) for GI neuroendocrine tumor metastatic to the liver from June 2004 to June 2009 were included. CT and MRI were evaluated for progression using Response Evaluation Criteria In Solid Tumors (RECIST) or European Association for the Study of the Liver (EASL) criteria. Short-term ( 3 months) imaging response was determined and Kaplan–Meier survival curves were plotted. Results: Thirty-eight drug-eluting bead chemoembolization procedures were performed on 32 hepatic lobes, comprising 21 treatment cycles in 18 patients. All procedures were technically successful with two major complications (biliary injuries). At short-term follow-up (<3 months), 22 of 38 (58%) procedures and 10 of 21 (48%) treatment cycles produced an objective response (OR) with the remainder having stable disease (SD). At intermediate-term follow-up (mean, 445 days; range, 163–1247), 17 of 26 (65%) procedures and 8 of 14 (57%) treatment cycles produced an OR. Probability of progressing was approximately 52% at 1 year with a median time to progression of 419 days. Conclusions: Drug-eluting bead chemoembolization is a reasonable alternative to hepatic arterial embolization and chemoembolization for the treatment of metastatic neuroendocrine tumor to the liver.

  3. Treatment of Unresectable Primary and Metastatic Liver Cancer with Yttrium-90 Microspheres (TheraSphere (registered) ): Assessment of Hepatic Arterial Embolization

    International Nuclear Information System (INIS)

    Sato, Kent; Lewandowski, Robert J.; Bui, James T.; Omary, Reed; Hunter, Russell D.; Kulik, Laura; Mulcahy, Mary; Liu, David; Chrisman, Howard; Resnick, Scott; Nemcek, Albert A.; Vogelzang, Robert; Salem, Riad

    2006-01-01

    In Canada and Europe, yttrium-90 microspheres (TheraSphere); MDS Nordion, Ottawa, Canada) are a primary treatment option for primary and secondary hepatic malignancies. We present data from 30 patients with hepatocellular carcinoma (HCC) and metastatic liver disease treated with TheraSphere from a single academic institution to evaluate the angiographically evident embolization that follows treatment. Seven interventional radiologists from one treatment center compared pretreatment and posttreatment angiograms. The reviewers were blinded to the timing of the studies. The incidence of postembolization syndrome (PES) was determined as well as objective tumor response rates by the World Health Organization (WHO), Response Evaluation Criteria in Solid Tumors (RECIST), and European Association for the Study of the Liver (EASL) criteria. There were 420 independent angiographic observations that were assessed using the chi-squared statistic. The pretreatment and posttreatment angiograms could not be correctly identified on average more than 43% of the time (p = 0.0004). The postprocedure arterial patency rate was 100%. The objective tumor response rates for all patients were 24%, 31%, and 72% for WHO, RECIST, and EASL criteria, respectively. All of the patients tolerated the procedure without complications and were treated on an outpatient basis, and four patients had evidence of PES. This treatment method does not result in macroscopic embolization of the hepatic arteries, thereby maintaining hepatic tissue perfusion. These data support the principle that the favorable response rates reported with TheraSphere are likely due to radiation and microscopic embolization rather than flow-related macroscopic embolization and ischemia

  4. A comparison of dobutamine and levosimendan on hepatic blood flow in patients with a low cardiac output state after cardiac surgery: a randomised controlled study.

    Science.gov (United States)

    Alvarez, J; Baluja, A; Selas, S; Otero, P; Rial, M; Veiras, S; Caruezo, V; Taboada, M; Rodriguez, I; Castroagudin, J; Tome, S; Rodriguez, A; Rodriguez, J

    2013-11-01

    Liver dysfunction due to a low cardiac output state after cardiac surgery is associated with a poor prognosis, but whether one inotrope is superior to another in improving hepatic perfusion remains uncertain. This study compared the systemic and hepatic haemodynamic effects of levosimendan to dobutamine in patients with a low cardiac output state (cardiac index flow (ml/min): 614.0±124.7, 585.9±144.8; pulsatility index: 2.02±0,28, 2.98±0.27 versus the levosimendan group: cardiac index: 3.02± 0.27, 2.98± 0.30; portal vein flow: 723.0± 143.5, 702.9±117.8; pulsatility index: 1.71±0.26, 1.73±0.27). The improvement in portal vein blood flow at 48 hours was significantly better after levosimendan than dobutamine (41% vs. 11% increment from baseline, Pflow through both the hepatic artery and portal venous system, whereas dobutamine can only improve the portal venous blood flow without vasodilating the hepatic artery.

  5. The prognosis and prognostic risk factors of patients with hepatic artery complications after liver transplantation treated with the interventional techniques

    International Nuclear Information System (INIS)

    Shan Hong; Huang Mingsheng; Jiang Zaipo; Zhu Kangshun; Yang Yang; Chen Guihua

    2008-01-01

    Objective: To investigate the prognosis and prognostic risk factors of hepatic artery complications after orthotopic liver transplantation (OLT) treated with the interventional techniques. Methods: The clinical data of 21 patients with hepatic artery complication after liver transplantation receiving thrombolysis, PTA, and stent placement in our institute from November 2003 to April 2007 were retrospectively analyzed. Based on the prognosis of grafts, 21 patients were divided into poor-prognosis group and non-poor-prognosis group. Fifteen variables (including biliary complication, hepatic artery restenosis, early or late artery complication, and so on) were analyzed in both groups with binary logistic regression analysis to screen out the risk factors related to prognosis of pereutaneous interventional treatment for hepatic artery complications after OLT. Results: Twenty-one patients were followed for mean 436 days, median 464 days (3-1037 days). The poor-prognosis group included 11 patients (5 cases received retransplantation, and 6 died). The mean survival time of grafts in poor-prognosis group was 191 days, and median survival time was 73 days (3-616 days). The mean survival time of grafts in non-poor-prognosis group which included 10 patients was 706 days, and median survival time was 692 days (245-1037 days). Univariate analysis showed there were significant difference in biliary complication, total bilimbin and indirect bilirubin between the two groups. The binary, logistic regression analysis showed the risk factor related to prognosis was with biliary complication before the interventional management (P=0.027, OR=22.818). Conclusion: Biliary complication before interventional management is the risk factor related to poor prognosis of patients with hepatic artery stenosis or thrombosis receiving interventional treatment. (authors)

  6. Experimental treatment of the transplanted hepatoma in rabbit by hepatic arterial embolization using interleukin-2 dextran microsphere and iodized

    International Nuclear Information System (INIS)

    Zeng Xiaohua; Wang Songzhang; Jin Deqin; Tang Ying; Ding Jinya; Feng Gansheng

    2006-01-01

    Objective: To observe the degree of necrosis in the transplanted hepatic tumor and the changes in immunity of the rabbits after hepatic arterial embolization using interleukin-2 (IL-2) dextran microsphere and iodized oil. Methods: IL-2 dextran microsphere and iodized oil were infused into hepatic artery of 20 rabbits with transplanted hepatic tumor. Infusion of dextran microspheres and iodized oil were taken in another transplanted hepatic tumor group of rabbits as the control. The blood samples were acquired pre-and post-embolization to measure the changes of IL-2 and sIL-2R in both groups. The rabbits were killed one week after the performance to get tumor tissue for pathologic examination. The comparison between using IL-2 dextran microsphere and dextran microsphere was made through optic and electronic microscopy for pathologic analysis. Results: Obvious increase of IL-2 and apparent decrease of sIL-2R in blood were demonstrated after the performance. The transplanted tumors mass underwent complete necrosis with false membranous capsule formation. In controlled group, slight increase of IL-2 and slight decrease of sIL-2R in blood were shown with partial central necrosis without false membraneous capsule formation of the transplanted tumor. Conclusions: The afficacy of the group IL-2 dextran microsphere was superior to group of arterial infusion of dextran microsphere in outcoming with tumor necrosis and strengthening the immunity of the rabbits. (authors)

  7. Giant hepatic artery aneurysm associated with immunoglobulin G4-related disease successfully treated using a liquid embolic agent

    Energy Technology Data Exchange (ETDEWEB)

    Rossi, Michele; Virgilio, Edoardo; Laurino, Florindo; Orgera, Gianluigi; Mene, Paolo; Pirozzi, Nicola; Ziparo, Vincenzo; Cavallini, Marco [St. Andrea Hospital, Rome (Italy)

    2015-08-15

    The occurrence of a giant hepatic artery aneurysm (GHAA) in a patient with systemic vasculitis is very rare. Herein, we describe our endovascular treatment experience of a GHAA associated with immunoglobulin G4-related disease (IgG4-RD) consisting primarily of a liquid embolic injection and deployment of a vascular plug.

  8. Transaxillary intra-arterial treatment of hepatic metastases with cytostatics and embolization: its control by isotope studies

    International Nuclear Information System (INIS)

    Voorthuisen, A.E. van; Herben, M.G.; Pauwels, E.K.J.

    1980-01-01

    Intra-arterial treatment of hepatic metastases has indicated that this is a rewarding procedure and that embolization of the liver has in a few cases resulted in a high remission rate lasting up to one or two years. The distribution of a cytostatic agent can be accurately controlled by isotope studies. (C.F.)

  9. Treatment of primany hepatic carcinoma with three-dimensional conformal radiation therapy combined with transcatheter arterial chemoembolization

    International Nuclear Information System (INIS)

    Wu Li; Wen Xiaoping; Huang Wei

    2006-01-01

    Objective: To evaluate the effects of three-dimensional conformal radiation therapy (3DCRT) combined with transcatheter arterial chemoembolization (TACE) on stage m/IV primary hepatic carcinoma. Methods: Eighty cases of stage III/IV primary hepatic carcinoma were randomly divided into two groups: 40 cases treated with three-dimensional conformal radiation therapy combined with transcatheter arterial chemoembolization (3DCRT + TACE group) and 40 cases treated with three-dimensional conformal radiation therapy associated with hepatic arterial infusion chemotherapy (3DCRT +HAI group). Results: The response rates were 75% and 45% in 3DCRT + TACE group and 3DCRT + HAI group, respectively; and the difference between the two groups was statistically significant (P 0.05), The 0.5-, 1- and 2-year survival rates were 73% , 45% and 28% in 3DCRT + TACE group, and 45%, 25% and 13% in 3DCRT + HAI group, respectively; and the difference between the two groups was statistically significant (P 0.05). Conclusion: Three-dimensional conformal radiation therapy combined with transcatheter arterial chemoembolization improved prognosis of stage III/IV primary hepatic carcinoma. (authors)

  10. Giant hepatic artery aneurysm associated with immunoglobulin G4-related disease successfully treated using a liquid embolic agent

    International Nuclear Information System (INIS)

    Rossi, Michele; Virgilio, Edoardo; Laurino, Florindo; Orgera, Gianluigi; Mene, Paolo; Pirozzi, Nicola; Ziparo, Vincenzo; Cavallini, Marco

    2015-01-01

    The occurrence of a giant hepatic artery aneurysm (GHAA) in a patient with systemic vasculitis is very rare. Herein, we describe our endovascular treatment experience of a GHAA associated with immunoglobulin G4-related disease (IgG4-RD) consisting primarily of a liquid embolic injection and deployment of a vascular plug

  11. MR measurement of coronary arterial blood flow velocity. Evaluation of age, stenosis and drugs as factors affecting coronary blood flow

    International Nuclear Information System (INIS)

    Taoka, Yoshiaki; Harada, Masafumi; Nishitani, Hiromu; Yukinaka, Michiko; Nomura, Masahiro

    1998-01-01

    Coronary arterial blood flow velocity was measured using MRI. Two types of phase contrast methods were used for the measurements, one of which exhibited good resolving power whereas the other provided more distinct images acquired while the subject patients held their breath. Before measuring coronary arterial blood flow velocity, accuracy of the two phase contrast methods was evaluated using a phantom. The results obtained with both methods largely agreed with the values obtained using the phantom. Using both methods, the patterns of coronary arterial blood flow over one cardiac cycle were essentially identical. A peak was noted in late systole or in early diastole in the right coronary artery, whereas in the left coronary artery, a peak was noted somewhat later in diastole. In healthy volunteers, no significant difference in the maximal flow velocity in the coronary arteries was found from one age group to another. Among patients with coronary arterial stenosis, coronary arterial blood flow velocity central to the area of stenosis was lower than that observed in the healthy volunteers. Coronary arterial blood flow velocity was observed to decrease after administration of isosorbide dinitrate and increased following administration of nifedipine. (author)

  12. Vertebral Artery Diameter and Flow: Nature or Nurture.

    Science.gov (United States)

    Tarnoki, Adam Domonkos; Fejer, Bence; Tarnoki, David Laszlo; Littvay, Levente; Lucatelli, Pierleone; Cirelli, Carlo; Fanelli, Fabrizio; Sacconi, Beatrice; Fagnani, Corrado; Medda, Emanuela; Farina, Filippo; Meneghetti, Giorgio; Horvath, Tamas; Pucci, Giacomo; Schillaci, Giuseppe; Stazi, Maria Antonietta; Baracchini, Claudio

    2017-09-01

    In contrast with the carotid arteries, the vertebral arteries (VAs) show considerable variation in length, caliber, and vessel course. This study investigated whether the variation in diameter and flow characteristics of the VAs might be inherited. A total of 172 Italian twins from Padua, Perugia, and Terni (54 monozygotic, 32 dizygotic) recruited from the Italian Twin Registry underwent B-mode and pulsed-wave Doppler ultrasound assessment of their VAs. VA diameters, peak systolic velocity (PSV) and end diastolic velocity (EDV) were assessed at the level of a horizontal V2 segment. Univariate quantitative genetic modeling was performed. Fourteen percent of the sample had VA hypoplasia. Within pair correlation in monozygotic twins was higher than in dizygotics (.552 vs. .229) for VA diameter. Age- and sex-adjusted genetic effect, under the most parsimonious model, accounted for 54.7% (95% CI: 42.2-69.1%) of the variance of VA diameter, and unshared environmental effect for 45.3% (95% CI: 30.9-57.8%). No heritability was found for the PSV of VA, but shared (34.1%; 95% CI: 16.7-53.7%) and unshared (65.9%; 95% CI: 45.9-83.1%) environmental factors determined the variance. EDV of VA is moderately genetically influenced (42.4%; 95% CI: 16.1-64.9%) and also determined by the unshared environment (57.6%; 95% CI: 34.7-83.7%). The diameter of the VAs is moderately genetically determined. Different factors influence the PSV and EDV of VAs, which may highlight the complex hemodynamic background of VA flow and help to understand the vertebral flow anomalies found by ultrasound. Copyright © 2017 by the American Society of Neuroimaging.

  13. Merging flows in an arterial confluence : The vertebro-basilar junction

    NARCIS (Netherlands)

    Ravensbergen, J; Krijger, JKB; Hillen, B; Hoogstraten, HW

    1995-01-01

    The basilar artery is one of the three vessels providing the blood supply to the human brain. It arises from the confluence of the two vertebral arteries. In fact, it is the only artery of this size in the human body arising from a confluence instead of a bifurcation. Earlier work, concerning flow

  14. Classification of hypervascular liver lesions based on hepatic artery and portal vein blood supply coefficients calculated from triphasic CT scans.

    Science.gov (United States)

    Boas, F Edward; Kamaya, Aya; Do, Bao; Desser, Terry S; Beaulieu, Christopher F; Vasanawala, Shreyas S; Hwang, Gloria L; Sze, Daniel Y

    2015-04-01

    Perfusion CT of the liver typically involves scanning the liver at least 20 times, resulting in a large radiation dose. We developed and validated a simplified model of tumor blood supply that can be applied to standard triphasic scans and evaluated whether this can be used to distinguish benign and malignant liver lesions. Triphasic CTs of 46 malignant and 32 benign liver lesions were analyzed. For each phase, regions of interest were drawn in the arterially enhancing portion of each lesion, as well as the background liver, aorta, and portal vein. Hepatic artery and portal vein blood supply coefficients for each lesion were then calculated by expressing the enhancement curve of the lesion as a linear combination of the enhancement curves of the aorta and portal vein. Hepatocellular carcinoma (HCC) and hypervascular metastases, on average, both had increased hepatic artery coefficients compared to the background liver. Compared to HCC, benign lesions, on average, had either a greater hepatic artery coefficient (hemangioma) or a greater portal vein coefficient (focal nodular hyperplasia or transient hepatic attenuation difference). Hypervascularity with washout is a key diagnostic criterion for HCC, but it had a sensitivity of 72 % and specificity of 81 % for diagnosing malignancy in our diverse set of liver lesions. The sensitivity for malignancy was increased to 89 % by including enhancing lesions that were hypodense on all phases. The specificity for malignancy was increased to 97 % (p = 0.039) by also examining hepatic artery and portal vein blood supply coefficients, while maintaining a sensitivity of 76 %.

  15. Radiological management of multiple hepatic artery pseudoaneurysms associated with cholangitic abscesses

    International Nuclear Information System (INIS)

    Goyal, Ankur; Madhusudhan, Kumble S; Gamanagatti, Shivanand; Baruah, Bhaskar; Shalimar; Sharma, Raju

    2016-01-01

    Hepatic artery pseudoaneurysms (HAP) are uncommon, occurring mostly as a complication of trauma (accidental or iatrogenic). Liver abscess rarely causes HAP and multiple HAP associated with cholangitic abscesses have not been reported in the literature. We present a patient of acute necrotizing pancreatitis with stent block cholangitis and multiple cholangitic abscesses who developed hemorrhagic output through drainage catheter in the liver abscess. A multiphasic CT angiography demonstrated three HAP, which were treated with a combination of endovascular coil embolization and percutaneous thrombin injection. The fact that cholangitic abscesses may be associated with pseudoaneurysms should not be neglected, considering the potentially catastrophic complication and relatively easy radiological management. CT angiography permits accurate diagnosis and lays down the roadmap for endovascular procedures

  16. Incidentally Detected Inoperable Malignant Pheochromocytoma with Hepatic Metastasis Treated by Transcatheter Arterial Chemoembolization

    Directory of Open Access Journals (Sweden)

    Joong Keun Kim

    2014-12-01

    Full Text Available Malignant pheochromocytoma (PCC is a rare condition. Although the liver is the second most frequent site of metastasis in malignant PCC, no definite treatments have been established. Herein, we report a case of liver metastasis of PCC that was successfully treated by transcatheter arterial chemoembolization (TACE. A 69-year-old man was admitted to the Department of Gastroenterology for evaluation of an incidental hepatic mass in August 2013. He had undergone right adrenalectomy in May 2005 and PCC had been confirmed on the basis of histopathological findings. Liver biopsy was performed, and metastatic PCC was diagnosed. The lesion appeared inoperable because of invasion of the portal vein and metastases in the lymph nodes along the hepatoduodenal ligament. Thus, TACE was performed instead. After TACE, symptoms including dizziness and cold sweating improved, and the patient's serum catecholamine levels decreased. On the basis of this case, we believe that TACE may be a useful treatment for liver metastasis in malignant PCC.

  17. Radiological management of multiple hepatic artery pseudoaneurysms associated with cholangitic abscesses

    Directory of Open Access Journals (Sweden)

    Ankur Goyal

    2016-01-01

    Full Text Available Hepatic artery pseudoaneurysms (HAP are uncommon, occurring mostly as a complication of trauma (accidental or iatrogenic. Liver abscess rarely causes HAP and multiple HAP associated with cholangitic abscesses have not been reported in the literature. We present a patient of acute necrotizing pancreatitis with stent block cholangitis and multiple cholangitic abscesses who developed hemorrhagic output through drainage catheter in the liver abscess. A multiphasic CT angiography demonstrated three HAP, which were treated with a combination of endovascular coil embolization and percutaneous thrombin injection. The fact that cholangitic abscesses may be associated with pseudoaneurysms should not be neglected, considering the potentially catastrophic complication and relatively easy radiological management. CT angiography permits accurate diagnosis and lays down the roadmap for endovascular procedures.

  18. Occlusive Hepatic Artery Thrombus in a Deceased-Donor Liver Procured From a Donor With Blunt Abdominal Trauma Following a Road Traffic Collision Accident.

    Science.gov (United States)

    Ahmad, Niaz; Tahir, Wasif; Haque, Ali; Dar, Faisal; Vilca-Melendez, Hector; Srinavasan, Parthi; Heaton, Nigel

    2018-04-09

    Here, we describe a case of occlusive hepatic artery thrombus in a liver procured from an 18-year-old deceased donor after circulatory death. The donor had died of multiple trauma following a road traffic collision. Occlusive thrombus was found at the hepatic artery bifurcation during back-table preparation. Consequently, the liver transplant did not proceed. We suggest careful assessment of hepatic arteries of all donor livers before transplant, particularly those from donors who are involved in deceleration injuries. Transplanting such livers may lead to primary nonfunction.

  19. Unraveling the relationship between arterial flow and intra-aneurysmal hemodynamics.

    Science.gov (United States)

    Morales, Hernán G; Bonnefous, Odile

    2015-02-26

    Arterial flow rate affects intra-aneurysmal hemodynamics but it is not clear how their relationship is. This uncertainty hinders the comparison among studies, including clinical evaluations, like a pre- and post-treatment status, since arterial flow rates may differ at each time acquisition. The purposes of this work are as follows: (1) To study how intra-aneurysmal hemodynamics changes within the full physiological range of arterial flow rates. (2) To provide characteristic curves of intra-aneurysmal velocity, wall shear stress (WSS) and pressure as functions of the arterial flow rate. Fifteen image-based aneurysm models were studied using computational fluid dynamics (CFD) simulations. The full range of physiological arterial flow rates reported in the literature was covered by 11 pulsatile simulations. For each aneurysm, the spatiotemporal-averaged blood flow velocity, WSS and pressure were calculated. Spatiotemporal-averaged velocity inside the aneurysm linearly increases as a function of the mean arterial flow (minimum R(2)>0.963). Spatiotemporal-averaged WSS and pressure at the aneurysm wall can be represented by quadratic functions of the arterial flow rate (minimum R(2)>0.996). Quantitative characterizations of spatiotemporal-averaged velocity, WSS and pressure inside cerebral aneurysms can be obtained with respect to the arterial flow rate. These characteristic curves provide more information of the relationship between arterial flow and aneurysm hemodynamics since the full range of arterial flow rates is considered. Having these curves, it is possible to compare experimental studies and clinical evaluations when different flow conditions are used. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Normal reference values for vertebral artery flow volume by color Doppler sonography in Korean adults

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Hyun Sook; Cha, Jang Gyu; Park, Seong Jin; Joh, Joon Hee; Park, Jai Soung; Kim, Dae Ho; Lee, Hae Kyung; Ahn, Hyun Cheol [Soonchunhyang University Bucheon Hospital, Bucheon (Korea, Republic of)

    2003-09-15

    Vertebrobasilar ischemia has been attributed to a reduction of net vertebral artery flow volume. This study was to establish the reference values for the flow volume of the vertebral artery using color Doppler sonography in the normal Korea adults. Thirty five normal Korea adults without any underlying disease including hypertension, hyperlipidemia, diabetes, heart disease, obesity (body mas index>30), or carotid artery stenosis was included. There were 17 males and 18 females, age ranged from 20 to 53 years (average=32.86 years). Flow velocities and vessel diameters were recorded in the intertransverse (V2) segment, usually at C5-6 level, bilaterally. The flow volume (Q) was calculated. (Q=time averaged mean velocity x cross sectional area of vessel) A lower Flow velocity and smaller vessel diameter were measured on the right side compared to those of the left side, resulting in a lower flow volume. The calculated flow volumes using the equation were 77.0 +- 39.7 ml/min for the right side and 127.6 +- 71.0 ml/min for the left side (p=0.0001) while the net vertebral artery flow volume was 204.6 +- 81.8 ml/min. Decrease in the vertebral artery flow volume was statistically significant with advanced age. (r=-0.36, p=0.032). Vertebral artery blood flow volume was 191.20 +- 59.19 ml/min in male, and 217.28 +- 98.67 ml/min in female (p=0.6). The normal range for the net vertebral artery flow volume defined by the 5th to 95th percentiles was between 110.06 and 364.1 ml/min. The normal range for the net vertebral artery flow volume was between 110.06 and 364.1 ml/min. Vertebral artery flow volume decreased with the increase of age. However, gender did not affect the blood flow volume.

  1. A Simplified Technique of Percutaneous Hepatic Artery Port-Catheter Insertion for the Treatment of Advanced Hepatocellular Carcinoma with Portal Vein Invasion

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Sun Young [Hallym University Sacred Heart Hospital, Anyang (Korea, Republic of); Kim, Ah Hyun; Lee, Do Yun; Lee, Kwang Hun; Won, Jong Yun [Yonsei University College of Medicine, Severance Hospital, Seoul (Korea, Republic of); Kim, Kyung Ah [Inje University Ilsan Paik Hospital, Ilsan (Korea, Republic of)

    2010-12-15

    We assessed the outcomes of a simplified technique for the percutaneous placement of a hepatic artery port-catheter system for chemotherapy infusion in advanced hepatocellular carcinoma with portal vein invasion. From February 2003 to February 2008, percutaneous hepatic artery port-catheter insertion was performed in 122 patients who had hepatocellular carcinoma with portal vein invasion. The arterial access route was the common femoral artery. The tip of the catheter was wedged into the right gastroepiploic artery without an additional fixation device. A side hole was positioned at the distal common hepatic artery to allow the delivery of chemotherapeutic agents into the hepatic arteries. Coil embolization was performed only to redistribute to the hepatic arteries or to prevent the inadvertent delivery of chemotherapeutic agents into extrahepatic arteries. The port chamber was created at either the supra-inguinal or infra-inguinal region. Technical success was achieved in all patients. Proper positioning of the side hole was checked before each scheduled chemotherapy session by port angiography. Catheter-related complications occurred in 19 patients (16%). Revision was achieved in 15 of 18 patients (83%). This simplified method demonstrates excellent technical feasibility, an acceptable range of complications, and is hence recommended for the management of advanced hepatocellular carcinoma with portal vein thrombosis

  2. Analysis of transit time flow of the right internal thoracic artery anastomosed to the left anterior descending artery compared to the left internal thoracic artery

    Science.gov (United States)

    Milani, Rodrigo; de Moraes, Daniela; Sanches, Aline; Jardim, Rodrigo; Lumikoski, Thais; Miotto, Gabriela; Santana, Vitor Hugo; Brofman, Paulo Roberto

    2014-01-01

    Introduction We evaluated with transit time flow the performance of the right and left thoracic arteries when used as a graft for the left anterior descending artery. Methods Fifty patients undergoing surgery for myocardial revascularization without cardiopulmonary bypass were divided into two groups. In group A patients received graft of right internal mammary artery to the anterior interventricular branch. In group B patients received graft of left internal mammary artery to the same branch. At the end of the operation the flow was assessed by measuring transit time. Results In group A, mean age was 60.6±9.49 years. The average height and weight of the group was 80.4±10.32 kg and 169.2±6.86 cm. The average number of grafts per patient in this group was 3.28±1.49. The mean flow and distal resistance obtained in right internal thoracic artery was 42.1±23.4 ml/min and 2.8±0.9 respectively. In group B, the mean age was 59.8±9.7 years. The average height and weight of this group was 77.7±14.22 kg and 166.0±8.2 cm. The average number of grafts per patient in this group was 3.08 ±0.82. The mean flow and distal resistance observed in this group was 34.2±19.1 ml/min and 2.0±0.7. There were no deaths in this series. Conclusion Right internal mammary artery presented a similar behavior to left internal mammary artery when anastomosed to the anterior interventricular branch of the left coronary artery. There was no statistical difference between the measured flow obtained between both arteries. PMID:25140463

  3. Hepatitis

    Science.gov (United States)

    ... most common types of viral hepatitis. What Is Hepatitis A? For kids, hep A is the most common ... they recover, it does not come back. Can Hepatitis A Be Prevented? The following will help keep people ...

  4. First pass effect by infusing 99mTc-human serum albumin into the hepatic artery

    International Nuclear Information System (INIS)

    Ozawa, Takashi; Kimura, Kousaburou; Koyanagi, Yasuhisa

    1988-01-01

    The fundamental principles of intra-arterial infusion chemotherapy are thought to be increased local drug concentration and the ''first-pass'' effect. The concentration in the rest of the body can only be decreased if there is local elimination of the infused drug before reaching the systemic circulation. This is referred to as the ''first-pass'' effect. In the evaluation of ''first-pass'' effect, the uptake of liver after infusing 99m Tc-human serum albumin ( 99m Tc-HSA) in the hepatic artery by injecting the subcutaneously implanted silicon reservoir was compared with that obtained after intravenous administration of 99m Tc-HSA. In order to remove the factor of portal infusion, each count of liver up take had been continued for only 24 seconds after starting the liver uptake. The results are as follows : for 24 cases excepting 6 cases with catheter obstruction, the mean i.a./i.v. ratio was 7.92 ± 3.34 (range 3.25 to 17.25). Although the elimination rate of drugs in the liver varies with each drug, the infusion of intraarterial chemotherapy should be about 8 times more concentrative than intravenous administration on the ''first-pass'' effect. (author)

  5. Place of Arterial Embolization in Severe Blunt Hepatic Trauma: A Multidisciplinary Approach

    International Nuclear Information System (INIS)

    Monnin, Valerie; Sengel, Christian; Thony, Frederic; Bricault, Ivan; Voirin, David; Letoublon, Christian; Broux, Christophe; Ferretti, Gilbert

    2008-01-01

    This study evaluates the efficacy of arterial embolization (AE) for blunt hepatic traumas (BHT) as part of a combined management strategy based on the hemodynamic status of patients and CT findings. From 2000 to 2005, 84 patients were admitted to our hospital for BHT. Of these, 14 patients who had high-grade injuries (grade III [n = 2], grade IV [n = 9], grade V [n = 3]) underwent AE because of arterial bleeding and were included in the study. They were classified into three groups according to their hemodynamic status: (1) unresponsive shock, (2) shock improved with resuscitation, and (3) hemodynamic stability. Four patients (group 1) underwent, first, laparotomy with packing and, then, AE for persistent bleeding. Ten patients who were hemodynamically stable (group 1) or even unstable (group 2) underwent AE first, based on CT findings. AE was successful in all cases. The mortality rate was 7% (1/14). Only two angiography-related complications (gallbladder infarction) were reported. Liver-related complications (abdominal compartment syndrome and biliary complications) were frequent and often required secondary interventions. Our multidisciplinary approach for the management of BHT gives a main role to embolization, even for hemodynamically unstable patients. In this strategy AE is very efficient and has a low complication rate.

  6. [Effect of PMU hepatic arterial chemotherapy for liver metastases of gastric cancer. Hokuriku Cisplatin Round-table Conference].

    Science.gov (United States)

    Sakuma, H; Matsuki, N; Katayama, K; Hirosawa, H; Tomita, F; Takano, N; Tanaka, T; Sawa, T; Ueno, K; Uogishi, M

    1989-08-01

    We performed PMU hepatic arterial chemotherapy (a combination therapy consisting of intra-hepatic arterial infusion of CDDP and MMC, oral administration of UFT) in 20 patients with gastric cancer and liver metastases. In this method, 1-6 courses of one infusion of CDDP at 70-100 mg/body and MMC of 10 mg/body into the proper hepatic artery were administered at intervals of 3-4 weeks. UFT of 300-400 mg/day was orally administered with the infusion. The primary response for hepatic metastatic lesions was observed in one case of CR, 14 cases of PR, 4 cases of NC, and one case of PD. The efficacy for CR and PR was high at 75%. The median disease-free interval was 56 weeks in responders. The 50% survival period was 11.1 months; one-year survival rate, 42.1%; two-year survival rate, 12.3%; the longest survival period was 108 weeks. Mild and transient side effects were recognized in 17 cases (85%): gastrointestinal symptoms, sense of general malaise, fever, leukocytopenia, and elevated BUN. Thus, the results indicated that this combination chemotherapy was effective for liver metastases of gastric cancer.

  7. A case of atherosclerotic inferior mesenteric artery aneurysm secondary to high flow state.

    Science.gov (United States)

    Troisi, Nicola; Esposito, Giovanni; Cefalì, Pietro; Setti, Marco

    2011-07-01

    Inferior mesenteric artery aneurysms are very rare and they are among the rarest of visceral artery aneurysms. Sometimes, the distribution of the blood flow due to chronic atherosclerotic occlusion of some arteries can establish an increased flow into a particular supplying district (high flow state). A high flow state in a stenotic inferior mesenteric artery in compensation for a mesenteric occlusive disease can produce a rare form of aneurysm. We report the case of an atherosclerotic inferior mesenteric aneurysm secondary to high flow state (association with occlusion of the celiac trunk and severe stenosis of the superior mesenteric artery), treated by open surgical approach. Copyright © 2011 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

  8. The Blood Disappearance Rate of 198Au-Colloid and Changes of Hepatic Blood Flow During Position Change in Normal Persons and in Patients with Various Hepatic Diseases

    International Nuclear Information System (INIS)

    Cho, Bo Yeon; Hong, Kee Suk; Koh, Chang Soon; Lee, Mun Ho

    1977-01-01

    To evaluate the diagnostic significance of the blood disappearance rate of 198 Au-colloid and to evaluate the change of hepatic blood flow during position change from supine to erect, we measured the half time of blood disappearance rate of 198 Au-colloid using external counting method in 94 normal persons and in 77 patients with various hepatic diseases. The results obtained were as follows: 1) In normal control, the mean blood disappearance half time of 198 Au-colloid in supine position was 2.7±0.4 minutes. There was no significant difference of hepatic blood flow in age and sex. 2) In acute hepatitis, chronic hepatitis and hepatic cirrhosis, the mean blood disappearance half times in supine position were 3.0±0.45, 3.5±0.74, 7.2±3.6 minutes respectively. The hepatic blood flow of the patients with chronic hepatitis and hepatic cirrhosis were significantly decreased than that of normal control. 3) In the normal control and acute hepatitis, the decreases of the hepatic blood flow during the position change from supine to erect were 27.7% and 22.6% respectively.

  9. Functional dilatation and medial remodeling of the renal artery in response to chronic increased blood flow.

    Science.gov (United States)

    Roan, Jun-Neng; Yeh, Chin-Yi; Chiu, Wen-Cheng; Lee, Chou-Hwei; Chang, Shih-Wei; Jiangshieh, Ya-Fen; Tsai, Yu-Chuan; Lam, Chen-Fuh

    2011-01-01

    Renal blood flow (RBF) is tightly regulated by several intrinsic pathways in maintaining optimal kidney blood supply. Using a rat model of aortocaval (AC) fistula, we investigated remodeling of the renal artery following prolonged increased blood flow. An AC fistula was created in the infrarenal aorta of anesthetized rats, and changes of blood flow in the renal artery were assessed using an ultrasonic flow probe. Morphological changes and expression of endothelial nitric oxide synthase and matrix metalloproteinase-2 in the remodeled renal artery were analyzed. Blood flow in the renal artery increased immediately after creation of AC fistula, but normal RBF was restored 8 weeks later. The renal artery dilated significantly 8 weeks after operation. Expression of endothelial nitric oxide synthase and matrix metalloproteinase-2 was upregulated shortly after blood flow increase, and returned to baseline levels after 3 weeks. Histological sections showed luminal dilatation with medial thickening and endothelial cell-to-smooth muscle cell attachments in the remodeled renal artery. Increased RBF was accommodated by functional dilatation and remodeling in the medial layer of the renal artery in order to restore normal blood flow. Our results provide important mechanistic insight into the intrinsic regulation of the renal artery in response to increased RBF. Copyright © 2011 S. Karger AG, Basel.

  10. Comparison of radial 4D Flow-MRI with perivascular ultrasound to quantify blood flow in the abdomen and introduction of a porcine model of pre-hepatic portal hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Frydrychowicz, A. [University of Wisconsin - Madison, Department of Radiology, School of Medicine and Public Health, E3/366 Clinical Science Center, Madison, WI (United States); University Hospital Schleswig-Holstein, Campus Luebeck, Clinic for Radiology and Nuclear Medicine, Luebeck (Germany); University of Luebeck, Luebeck (Germany); Roldan-Alzate, A. [University of Wisconsin - Madison, Department of Radiology, School of Medicine and Public Health, E3/366 Clinical Science Center, Madison, WI (United States); University of Wisconsin, Department of Mechanical Engineering, Madison (United States); Winslow, E. [University of Wisconsin, Department of Surgery, Madison (United States); Consigny, D.; Campo, C.A.; Motosugi, U. [University of Wisconsin - Madison, Department of Radiology, School of Medicine and Public Health, E3/366 Clinical Science Center, Madison, WI (United States); Johnson, K.M. [University of Wisconsin, Department of Medical Physics, Madison (United States); Wieben, O. [University of Wisconsin - Madison, Department of Radiology, School of Medicine and Public Health, E3/366 Clinical Science Center, Madison, WI (United States); University of Wisconsin, Department of Medical Physics, Madison (United States); Reeder, S.B. [University of Wisconsin - Madison, Department of Radiology, School of Medicine and Public Health, E3/366 Clinical Science Center, Madison, WI (United States); University of Wisconsin, Department of Medical Physics, Madison (United States); University of Wisconsin, Department of Biomedical Engineering, Madison (United States); University of Wisconsin, Department of Medicine, Madison (United States); University of Wisconsin, Department of Emergency Medicine, Madison (United States)

    2017-12-15

    Objectives of this study were to compare radial time-resolved phase contrast magnetic resonance imaging (4D Flow-MRI) with perivascular ultrasound (pvUS) and to explore a porcine model of acute pre-hepatic portal hypertension (PHTN). Abdominal 4D Flow-MRI and pvUS in portal and splenic vein, hepatic and both renal arteries were performed in 13 pigs of approximately 60 kg. In six pigs, measurements were repeated after partial portal vein (PV) ligature. Inter- and intra-reader comparisons and statistical analysis including Bland-Altman (BA) comparison, paired Student's t tests and linear regression were performed. PvUS and 4D Flow-MRI measurements agreed well; flow before partial PV ligature was 322 ± 30 ml/min in pvUS and 297 ± 27 ml/min in MRI (p = 0.294), and average BA difference was 25 ml/min [-322; 372]. Inter- and intra-reader results differed very little, revealed excellent correlation (R {sup 2} = 0.98 and 0.99, respectively) and resulted in BA differences of -5 ml/min [-161; 150] and -2 ml/min [-28; 25], respectively. After PV ligature, PV flow decreased from 356 ± 50 to 298 ± 61 ml/min (p = 0.02), and hepatic arterial flow increased from 277 ± 36 to 331 ± 65 ml/min (p = n.s.). The successful in vivo comparison of radial 4D Flow-MRI to perivascular ultrasound revealed good agreement of abdominal blood flow although with considerable spread of results. A model of pre-hepatic PHTN was successfully introduced and acute responses monitored. (orig.)

  11. Perioperative Hemodynamic Monitoring of Common Hepatic Artery for Endovascular Embolization of a Pancreaticoduodenal Arcade Aneurysm with Celiac Stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Shibata, Eisuke, E-mail: eisuke.shibata1130@gmail.com; Takao, Hidemasa; Amemiya, Shiori; Ohtomo, Kuni [The University of Tokyo, Department of Radiology, Graduate School of Medicine (Japan)

    2017-03-15

    This report describes perioperative hemodynamic monitoring of the common hepatic artery (CHA) during endovascular treatment of a pancreaticoduodenal arcade aneurysm, in a patient with celiac artery stenosis caused by the median arcuate ligament. Pressure monitoring was performed as a safety measure against critical complications such as liver ischemia. As the aneurysm was located in the anterior pancreaticoduodenal artery (APDA) and the posterior pancreaticoduodenal artery (PPDA) was small in caliber, the patient was considered to be at a high risk of liver ischemia. No significant change in pressure was observed in the CHA on balloon occlusion test in the APDA. Immediately after embolization, the PPDA enlarged and the pressure in the CHA was well maintained. Pressure monitoring appears to improve patient safety during endovascular treatment of visceral aneurysms.

  12. Perioperative Hemodynamic Monitoring of Common Hepatic Artery for Endovascular Embolization of a Pancreaticoduodenal Arcade Aneurysm with Celiac Stenosis

    International Nuclear Information System (INIS)

    Shibata, Eisuke; Takao, Hidemasa; Amemiya, Shiori; Ohtomo, Kuni

    2017-01-01

    This report describes perioperative hemodynamic monitoring of the common hepatic artery (CHA) during endovascular treatment of a pancreaticoduodenal arcade aneurysm, in a patient with celiac artery stenosis caused by the median arcuate ligament. Pressure monitoring was performed as a safety measure against critical complications such as liver ischemia. As the aneurysm was located in the anterior pancreaticoduodenal artery (APDA) and the posterior pancreaticoduodenal artery (PPDA) was small in caliber, the patient was considered to be at a high risk of liver ischemia. No significant change in pressure was observed in the CHA on balloon occlusion test in the APDA. Immediately after embolization, the PPDA enlarged and the pressure in the CHA was well maintained. Pressure monitoring appears to improve patient safety during endovascular treatment of visceral aneurysms.

  13. Origins of feeding arteries of hepatocellular carcinoma located near the umbilical fissure of the left hepatic lobe: angiographic evaluation.

    Science.gov (United States)

    Miyayama, Shiro; Yamashiro, Masashi; Shibata, Yoshihiro; Hashimoto, Masahiro; Yoshida, Miki; Tsuji, Kazunobu; Toshima, Fumihito; Matsui, Osamu

    2012-12-01

    To analyze the origins of the feeding arteries of hepatocellular carcinomas (HCCs) near the umbilical fissure of the left hepatic lobe. Twenty-eight HCCs with a mean ± SD tumor diameter of 3.4 ± 1.0 cm (range 1-4.4 cm) in contact with the right or left side of the umbilical fissure were treated by superselective transcatheter arterial chemoembolization (TACE). The origins of the tumor-feeding arteries were analyzed with arteriograms and computed tomography or cone-beam computed tomography images obtained during and 1 week after TACE. Twenty-one HCC lesions were located in segment 3 and seven were located in segment 4. Of 21 tumors in segment 3, 13 (61.9%) were supplied by the lateral inferior subsegmental artery (A3), three (14.3%) by the medial subsegmental artery (A4), three (14.3%) by both A4 and A3, one (4.8%) by a branch arising from the left lateral hepatic artery, and one (4.8%) by a branch of the right gastric artery. In particular, all tumor-feeding branches arising from A4 were the first branch of A4. Of seven tumors in segment 4, four (57.1%) were supplied by A4 and three (42.9%) by A3. In particular, all tumor-feeding branches arising from A3 were the first branch of A3. This study demonstrates crossover blood supply to HCC lesions located near the umbilical fissure, in addition to direct feeding from a separate branch. In particular, the first branch of the opposite subsegmental artery may feed tumors when crossover blood supply is present.

  14. Origins of Feeding Arteries of Hepatocellular Carcinoma Located Near the Umbilical Fissure of the Left Hepatic Lobe: Angiographic Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Miyayama, Shiro, E-mail: s-miyayama@fukui.saiseikai.or.jp; Yamashiro, Masashi; Shibata, Yoshihiro; Hashimoto, Masahiro; Yoshida, Miki; Tsuji, Kazunobu; Toshima, Fumihito [Fukuiken Saiseikai Hospital, Department of Diagnostic Radiology (Japan); Matsui, Osamu [Kanazawa University Graduate School of Medical Science, Department of Radiology (Japan)

    2012-12-15

    Purpose: To analyze the origins of the feeding arteries of hepatocellular carcinomas (HCCs) near the umbilical fissure of the left hepatic lobe. Methods: Twenty-eight HCCs with a mean {+-} SD tumor diameter of 3.4 {+-} 1.0 cm (range 1-4.4 cm) in contact with the right or left side of the umbilical fissure were treated by superselective transcatheter arterial chemoembolization (TACE). The origins of the tumor-feeding arteries were analyzed with arteriograms and computed tomography or cone-beam computed tomography images obtained during and 1 week after TACE.ResultsTwenty-one HCC lesions were located in segment 3 and seven were located in segment 4. Of 21 tumors in segment 3, 13 (61.9%) were supplied by the lateral inferior subsegmental artery (A3), three (14.3%) by the medial subsegmental artery (A4), three (14.3%) by both A4 and A3, one (4.8%) by a branch arising from the left lateral hepatic artery, and one (4.8%) by a branch of the right gastric artery. In particular, all tumor-feeding branches arising from A4 were the first branch of A4. Of seven tumors in segment 4, four (57.1%) were supplied by A4 and three (42.9%) by A3. In particular, all tumor-feeding branches arising from A3 were the first branch of A3. Conclusion: This study demonstrates crossover blood supply to HCC lesions located near the umbilical fissure, in addition to direct feeding from a separate branch. In particular, the first branch of the opposite subsegmental artery may feed tumors when crossover blood supply is present.

  15. Safety and effectiveness of repeat arterial closure using the AngioSeal device in patients with hepatic malignancy.

    Science.gov (United States)

    Hieb, Robert A; Neisen, Melissa J; Hohenwalter, Eric J; Molnar, Jim A; Rilling, William S

    2008-12-01

    To retrospectively evaluate the safety and effectiveness of the use of the AngioSeal device for repeat arterial closure in patients with hepatic malignancy. A retrospective analysis of patients with hepatic malignancy who had undergone repeated arterial closure with the AngioSeal device was performed. All charts for patients undergoing transarterial chemoembolization or TheraSphere radioembolization were reviewed for the method of hemostasis and the number of arterial closures. A total of 53 patients (58.5% men, 41.5% women; mean age, 58.7 years) had repeat AngioSeal arterial puncture closure after chemoembolization or TheraSphere treatment. Percutaneous closure of the common femoral artery with the AngioSeal device was performed in accordance with the manufacturer's recommendations. The patients were examined for complications on follow-up. Effectiveness was defined by the ability to obtain satisfactory hemostasis. Safety was assessed by the absence of groin complications and by vessel patency on follow-up angiograms of the puncture site obtained at subsequent liver-directed therapy sessions. Fifty-three patients in this study group had a total of 203 common femoral artery punctures. There were a total of 161 closures with the AngioSeal device (79.3%): 58 (36%) single closures and 103 (64.0%) repeat closures. Of the 161 attempts at AngioSeal closure, there was one closure failure in the single-puncture group, yielding a success rate of 98.3%; and one closure failure in the repeat-puncture group, yielding a success rate of 99%. In these two patients, hemostasis was achieved with traditional manual compression without the need for any other device, and no complications were noted. The overall success rate of AngioSeal device closure was 98.7%. The repeat use of the AngioSeal closure device is safe and effective in patients with hepatic malignancy undergoing regional oncologic interventional procedures.

  16. Doppler Flow Wire Evaluation of Renal Blood Flow Reserve in Hypertensive Patients with Normal Renal Arteries

    International Nuclear Information System (INIS)

    Beregi, Jean-Paul; Mounier-Vehier, Claire; Devos, Patrick; Gautier, Corinne; Libersa, Christian; McFadden, Eugene P.; Carre, Alain

    2000-01-01

    Purpose: To study the vasomotor responses of the renal microcirculation in patients with essential hypertension.Methods: We studied the reactivity of the renal microcirculation to papaverine, with intraarterial Doppler and quantitative arteriography, in 34 renal arteries of 19 hypertensive patients without significant renal artery stenosis. Isosorbide dinitrate was given to maximally dilate proximal renal arteries. APV (average peak blood flow velocity) was used as an index of renal blood flow.Results: Kidneys could be divided into two distinct subgroups based on their response to papaverine. An increase in APV of up to 55% occurred in 21 kidneys, an increase > 55% in 13 kidneys. Within each group the values were normally distributed. Both baseline APV and the effect of papaverine on mean velocity differed significantly between groups.Conclusion: There seems to be a subgroup of patients with essential hypertension that has an impaired reactivity to papaverine, consistent with a functional impairment of the renal microcirculation. Further studies are required to determine whether this abnormality contributes to or results from elevated blood pressure

  17. Hepatic blood flow and splanchnic oxygen consumption in patients with liver failure. Effect of high-volume plasmapheresis.

    Science.gov (United States)

    Clemmesen, J O; Gerbes, A L; Gülberg, V; Hansen, B A; Larsen, F S; Skak, C; Tygstrup, N; Ott, P

    1999-02-01

    Liver failure represents a major therapeutic challenge, and yet basic pathophysiological questions about hepatic perfusion and oxygenation in this condition have been poorly investigated. In this study, hepatic blood flow (HBF) and splanchnic oxygen delivery (DO2, sp) and oxygen consumption (VO2,sp) were assessed in patients with liver failure defined as hepatic encephalopathy grade II or more. Measurements were repeated after high-volume plasmapheresis (HVP) with exchange of 8 to 10 L of plasma. HBF was estimated by use of constant infusion of D-sorbitol and calculated according to Fick's principle from peripheral artery and hepatic vein concentrations. In 14 patients with acute liver failure (ALF), HBF (1.78 +/- 0.78 L/min) and VO2,sp (3.9 +/- 0.9 mmol/min) were higher than in 11 patients without liver disease (1.07 +/- 0.19 L/min, P HVP, HBF increased from 1.67 +/- 0.72 to 2.07 +/- 1.11 L/min (n=11) in ALF, and from 1.89 +/- 1.32 to 2.34 +/- 1.54 L/min (n=7) in AOCLD, P HVP. Blood flow was redirected to the liver as the systemic vascular resistance index increased (1,587 +/- 650 vs. 2, 020 +/- 806 Dyne. s. cm-5. m2, P HVP, but as cardiac output increased from 9.1 +/- 2.8 to 10.1 +/- 2.9 L/min (P HVP (n=18), DO2,sp increased by 15% (P HVP. Changes of ET-1 were positively correlated with changes in HBF (P HVP (P HVP did not correlate. Our data suggest that liver failure is associated with increased HBF and VO2, sp. HVP further increased HBF and DO2,sp but VO2,sp was unchanged, indicating that splanchnic hypoxia was not present.

  18. Middle cerebral artery flow velocity and blood flow during exercise and muscle ischemia in humans

    DEFF Research Database (Denmark)

    Jørgensen, L G; Perko, M; Hanel, B

    1992-01-01

    Changes in middle cerebral artery flow velocity (Vmean), measured by transcranial Doppler ultrasound, were used to determine whether increases in mean arterial pressure (MAP) or brain activation enhance cerebral perfusion during exercise. We also evaluated the role of "central command......, they support the hypothesis that cerebral perfusion during exercise reflects an increase in brain activation that is independent of MAP, central command, and muscle metaboreceptors but is likely to depend on influence of mechanoreceptors.......," mechanoreceptors, and/or muscle "metaboreceptors" on cerebral perfusion. Ten healthy subjects performed two levels of dynamic exercise corresponding to a heart rate of 110 (range 89-134) and 148 (129-170) beats/min, respectively, and exhaustive one-legged static knee extension. Measurements were continued during 2...

  19. Analysis of cerebral blood flow and intracranial hypertension in critical patients with non-hepatic hyperammonemia.

    Science.gov (United States)

    Larangeira, Alexandre Sanches; Tanita, Marcos Toshiyuki; Dias, Marcos Antonio; Filho, Olavo Franco Ferreira; Delfino, Vinicius Daher Alvares; Cardoso, Lucienne Tibery Queiroz; Grion, Cintia Magalhães Carvalho

    2018-05-03

    Hyperammonemia in adults is generally associated with cerebral edema, decreased cerebral metabolism, and increased cerebral blood flow. The aim of this study was to evaluate the association between non-hepatic hyperammonemia and intracranial hypertension assessed by Doppler flowmetry and measurement of the optic nerve sheath. A prospective cohort study in critically ill patients hospitalized in intensive care units of a University Hospital between March 2015 and February 2016. Clinical data and severity scores were collected and the Glasgow coma scale was recorded. Serial serum ammonia dosages were performed in all study patients. Transcranial Doppler evaluation was carried out for the first 50 consecutive results of each stratum of ammonemia: normal (<35 μmol/L), mild hyperammonemia (≥35 μmol/L and < 50 μmol/L), moderate hyperammonemia (≥50 μmol/L and < 100 μmol/L), and severe hyperammonemia (≥100 μmol/L). The measurement of the optic nerve sheath was performed at the same time as the Doppler examination if the patient scored less than 8 on the Glasgow coma scale. There was no difference in flow velocity in the cerebral arteries between patients with and without hyperammonemia. Patients with hyperammonemia presented longer ICU stay. Optic nerve sheath thickness was higher in the group with severe hyperammonemia and this group presented an association with intracranial hypertension. Higher mortality was observed in the severe hyperammonemia group. There was an association between severe hyperammonemia and signs of intracranial hypertension. No correlation was found between ammonia levels and cerebral blood flow velocity through the Doppler examination.

  20. Blood disappearance rate of /sup 198/Au-colloid and changes of hepatic blood flow during position change in normal persons and in patients with various hepatic diseases

    Energy Technology Data Exchange (ETDEWEB)

    Cho, B Y [Capital Armed Forces General Hospital, Seoul (Republic of Korea); Hong, K S; Koh, C S; Lee, M [Seoul National Univ., Seoul (Republic of Korea). Coll. of Medicine

    1977-01-01

    To evaluate the diagnostic significance of the blood disappearance rate of /sup 198/Au-colloid and to evaluate the change of hepatic blood flow during position change from supine to erect, we measured the half time of blood disappearance rate of 7,1/sup 98/Au-colloid using external counting method in 94 normal persons and in 77 patients with various hepatic diseases. The results obtained were as follows: 1. In normal control, the mean blood disappearance half time of /sup 198/Au-colloid in supine position was 2.7+-0.4 minutes. There was no significant difference of hepatic blood flow in age and sex. 2. In acute hepatitits, chronic hepatitis and hepatic cirrhosis, the mean blood disappearance half times in supine position were 3.0+-0.45, 3.5+-0.74, 7.2+-3.6 minutes respectively. The hepatic blood flow of the patients with chronic hepatitis and hepatic cirrhosis were significantly decreased than that of normal control. 3. In the normal control and acute hepatitis, the decreaces of the hepatic blood flow during the position change from supine to erect were 27.7% and 22.6% respectively.

  1. The blood disappearance rate of 198Au-colloid and changes of hepatic blood flow during position change in normal persons and in patients with various hepatic diseases

    International Nuclear Information System (INIS)

    Cho, B.Y.; Hong, K.S.; Koh, C.S.; Lee, M.

    1977-01-01

    To evaluate the diagnostic significance of the blood disappearance rate of 198 Au-colloid and to evaluate the change of hepatic blood flow during position change from supine to erect, we measured the half time of blood disappearance rate of 7,1 98 Au-colloid using external counting method in 94 normal persons and in 77 patients with various hepatic diseases. The results obtained were as follows: 1. In normal control, the mean blood disappearance half time of 198 Au-colloid in supine position was 2.7+-0.4 minutes. There was no significant difference of hepatic blood flow in age and sex. 2. In acute hepatitits, chronic hepatitis and hepatic cirrhosis, the mean blood disappearance half times in supine position were 3.0+-0.45, 3.5+-0.74, 7.2+-3.6 minutes respectively. The hepatic blood flow of the patients with chronic hepatitis and hepatic cirrhosis were significantly decreased than that of normal control. 3. In the normal control and acute hepatitis, the decreaces of the hepatic blood flow during the position change from supine to erect were 27.7% and 22.6% respectively. (author)

  2. Comparison of survival rates among different treatment methods of transcatheter hepatic arterial chemoembolization for hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Shim, Yong Woon; Lee, Jong Tae; Yoo, Hyung Sik; Lee, Do Yun; Jun, Pyoung Jun; Chang, So Yong [Yonsei Univ. College of Medicine, Seoul (Korea, Republic of)

    1996-06-01

    To compare the survival rates of patients with hepatoma using different methods of transcatheter arterial chemoemblization(THAE). Four hundred and eighty three patients with hepatoma diagnosed by biopsy, serum alpha-fetoprotein, abdominal CT scan, abdominal ultrasonography or hepatic angiography were included, but not all had received surgical treatment. They were divided onto two groups according to Child's classification and into subgroups according to different methods of THAE. Five-tear survival rates among these groups were retrospectively compared. The patients were aged between 24 and 85(mean, 58) ; male to female ratio was 324 : 61 for those who received THAE (369 : 87 when only hepatic angiography was considered.). In the group with more than a single episode of chemoembolization, regardless of Child's classification, a better survival rate compared to the other groups with or without concommitant radiotherapy or without chemoembolization was noted. There was no difference in the survival rate of patients with multiple chemoembolization. moreover, no difference in this rate was observed no matter what chemotherapeutic agents, including Adriamycin, Cis-Diaminedichloroplatinum of I-131-Lipiodol, were used. Amortization by gelfoam in conjuction with Adriamycin resulted in no difference in survival rate regardless of frequency of chemoembolization. An improved survival rate was seen when multiple episodes of chemoembolization were applied, but no difference was seen when there was concomitant application of either gelfoam or radiotherapy. Two different chemotherapeutic agents, Adriamycin and Cis-Diaminedichloroplatinum, were used, but there was no difference between them in their effect on survival rates.

  3. Relationship of 133Xe cerebral blood flow to middle cerebral arterial flow velocity in men at rest

    Science.gov (United States)

    Clark, J. M.; Skolnick, B. E.; Gelfand, R.; Farber, R. E.; Stierheim, M.; Stevens, W. C.; Beck, G. Jr; Lambertsen, C. J.

    1996-01-01

    Cerebral blood flow (CBF) was measured by 133Xe clearance simultaneously with the velocity of blood flow through the left middle cerebral artery (MCA) over a wide range of arterial PCO2 in eight normal men. Average arterial PCO2, which was varied by giving 4% and 6% CO2 in O2 and by controlled hyperventilation on O2, ranged from 25.3 to 49.9 mm Hg. Corresponding average values of global CBF15 were 27.2 and 65.0 ml 100 g min-1, respectively, whereas MCA blood-flow velocity ranged from 42.8 to 94.2 cm/s. The relationship of CBF to MCA blood-flow velocity over the imposed range of arterial PCO2 was described analytically by a parabola with the equation: CBF = 22.8 - 0.17 x velocity + 0.006 x velocity2 The observed data indicate that MCA blood-flow velocity is a useful index of CBF response to change in arterial PCO2 during O2 breathing at rest. With respect to baseline values measured while breathing 100% O2 spontaneously, percent changes in velocity were significantly smaller than corresponding percent changes in CBF at increased levels of arterial PCO2 and larger than CBF changes at the lower arterial PCO2. These observed relative changes are consistent with MCA vasodilation at the site of measurement during exposure to progressive hypercapnia and also during extreme hyperventilation hypocapnia.

  4. Combined therapy involving hepatic arterial chemoinfusion through a percutaneously implanted port, and external irradiation for advanced hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Kim, Jong Won; Suh, Sang Hyun; Won, Jong Yun

    2002-01-01

    To evaluate the efficacy of combined therapy involving intra-arterial hepatic chemoinfusion through a percutaneously implanted port and external irradiation for the treatment of advanced hepatocellular carcinoma. Fifteen patients (2 males and 3 females; mean age=47.5 years) with advanced hepatocellular carcinoma localized in one lobe and with portal vein thrombosis (stage IVa) were included in this study. To permit chemoinfusion through the hepatic artery, a chemoport was implanted percutaneously in the right inguinal area via the femoral artery. Initial external radiation therapy lasted five weeks (44 Gy in a daily fraction of 1.8 Gy), with concurrent intra-arterial hepatic infusion of 5-fluorouracil. This initial treatment was followed by five cycles of intra-arterial hepatic infusion of cisplatin and 5-fluorouracil for three consecutive days every month.Two and six months after treatment was begun, the patients underwent CT scanning and angiography, and their response was assessed in terms of change in tumor size and vascularity, the degree of portal vein thrombosis and arterio-portal shunt, and alpha-fetoprotein levels. Any complications arising from this combined therapy and the clinical status of each patient were also followed up during the treatment period. The response rates at months 2 and 6 were 60% and 33.3%, respectively. One patient (6.7%) showed complete remission, and serum alpha-fetoprotein levels decreased significantly in all patients who responded. In five of the twelve patients, the thrombi in the main portal vein showed marked regression. The one-year survival rate was 30% and the median survival period was 10.6 (range, 3.7 to 28) months. The complications arising after treatment involved the catheter-port system (n=2) or were due to gastroduodenitis (n=9). In these patients with advanced hepatocellular carcinoma and portal vein thronbosis, combined therapy involving hepatic arterial chemoinfusion through a chemoport and external irradiation

  5. Combined therapy involving hepatic arterial chemoinfusion through a percutaneously implanted port, and external irradiation for advanced hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Kim, Jong Won; Suh, Sang Hyun; Won, Jong Yun; Lee, Do Yun; Park, Sung Il; Lee, Jong Tae; Moon, Young Myoung; Chon, Chae Yoon; Han, Kwang Hyup; Seoung, Jin Sil

    2002-01-01

    To evaluate the efficacy of combined therapy involving intra-arterial hepatic chemoinfusion through a percutaneously implanted port and external irradiation for the treatment of advanced hepatocellular carcinoma. Fifteen patients (12 males and 3 females; mean age = 47.5 years) with advanced hepatocellular carcinoma localized in one lobe and with portal vein thrombosis (stage IVa) were included in this study. To permit chemoinfusion through the hepatic artery, a Chemoport was implanted percutaneously in the right inguinal area via the femoral artery. Initial external radiation therapy lasted five weeks (44 Gy in a daily fraction of 1.8 Gy), with concurrent intra-arterial hepatic infusion of 5-fluorouracil. This initial treatment was followed by five cycles of intra-arterial hepatic infusion of cisplatin and 5-fluorouracil for three consecutive days every month. Two and six months after treatment was begun, the patients underwent CT scanning and angiography, and their response was assessed in terms of change in tumor size and vascularity, the degree of portal vein thrombosis and arterio-portal shunt, and alpha-fetoprotein levels. Any complications arising from this combined therapy and the clinical status of each patient were also followed up during the treatment period. The response rates at months 2 and 6 were 60% and 33.3%, respectively. One patient (6.7%) showed complete remission, and serum alpha-fetoprotein levels decreased significantly in all patients who responded. In five of the twelve patients, the thrombi in the main portal vein showed marked regression. The one-year survival rate was 30% and the median survival period was 10.6 (range, 3.7 to 28) months. The complications arising after treatment involved the catheter-port system (n=2) or were due to gastroduodenitis (n=9). In these patients with advanced hepatocellular carcinoma and portal vein thronbosis, combined therapy involving hepatic arterial chemoinfusion through a chemoport and external

  6. Combined therapy involving hepatic arterial chemoinfusion through a percutaneously implanted port, and external irradiation for advanced hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong Won; Suh, Sang Hyun; Won, Jong Yun [Yonsei University College of Medicine, Seoul (Korea, Republic of)] [and others

    2002-12-01

    To evaluate the efficacy of combined therapy involving intra-arterial hepatic chemoinfusion through a percutaneously implanted port and external irradiation for the treatment of advanced hepatocellular carcinoma. Fifteen patients (2 males and 3 females; mean age=47.5 years) with advanced hepatocellular carcinoma localized in one lobe and with portal vein thrombosis (stage IVa) were included in this study. To permit chemoinfusion through the hepatic artery, a chemoport was implanted percutaneously in the right inguinal area via the femoral artery. Initial external radiation therapy lasted five weeks (44 Gy in a daily fraction of 1.8 Gy), with concurrent intra-arterial hepatic infusion of 5-fluorouracil. This initial treatment was followed by five cycles of intra-arterial hepatic infusion of cisplatin and 5-fluorouracil for three consecutive days every month.Two and six months after treatment was begun, the patients underwent CT scanning and angiography, and their response was assessed in terms of change in tumor size and vascularity, the degree of portal vein thrombosis and arterio-portal shunt, and alpha-fetoprotein levels. Any complications arising from this combined therapy and the clinical status of each patient were also followed up during the treatment period. The response rates at months 2 and 6 were 60% and 33.3%, respectively. One patient (6.7%) showed complete remission, and serum alpha-fetoprotein levels decreased significantly in all patients who responded. In five of the twelve patients, the thrombi in the main portal vein showed marked regression. The one-year survival rate was 30% and the median survival period was 10.6 (range, 3.7 to 28) months. The complications arising after treatment involved the catheter-port system (n=2) or were due to gastroduodenitis (n=9). In these patients with advanced hepatocellular carcinoma and portal vein thronbosis, combined therapy involving hepatic arterial chemoinfusion through a chemoport and external irradiation

  7. 188Re-SSS lipiodol: radiolabelling and biodistribution following injection into the hepatic artery of rats bearing hepatoma.

    Science.gov (United States)

    Garin, Etienne; Denizot, Benoit; Noiret, Nicolas; Lepareur, Nicolas; Roux, Jerome; Moreau, Myriam; Herry, Jean-Yves; Bourguet, Patrick; Benoit, Jean-Pierre; Lejeune, Jean-Jacques

    2004-10-01

    Although intra-arterial radiation therapy with 131I-lipiodol is a useful therapeutic approach to the treatment of hepatocellular carcinoma, various disadvantages limit its use. To describe the development of a method for the labelling of lipiodol with 188Re-SSS (188Re (S2CPh)(S3CPh)2 complex) and to investigate its biodistribution after injection into the hepatic artery of rats with hepatoma. 188Re-SSS lipiodol was obtained after dissolving a chelating agent, previously labelled with 188Re, in cold lipiodol. The radiochemical purity (RCP) of labelling was checked immediately. The 188Re-SSS lipiodol was injected into the hepatic artery of nine rats with a Novikoff hepatoma. They were sacrificed 1, 24 and 48 h after injection, and used for ex vivo counting. Labelling of 188Re-SSS lipiodol was achieved with a yield of 97.3+/-2.1%. The immediate RCP was 94.1+/-1.7%. Ex vivo counting confirmed a predominantly hepatic uptake, with a good tumoral retention of 188Re-SSS lipiodol, a weak pulmonary uptake and a very faint digestive uptake. The 'tumour/non-tumoral liver' ratio was high at 1, 24 and 48 h after injection (2.9+/-1.5, 4.1+/-/4.1 and 4.1+/-0.7, respectively). Using the method described here, 188Re-SSS lipiodol can be obtained with a very high yield and a satisfactory RCP. The biodistribution in rats with hepatoma indicates a good tumoral retention of 188Re-SSS lipiodol associated with a predominant hepatic uptake, a weak pulmonary uptake and a very faint digestive uptake. This product should be considered for intra-arterial radiation therapy in human hepatoma.

  8. Utilizing generalized autocalibrating partial parallel acquisition (GRAPPA) to achieve high-resolution contrast-enhanced MR angiography of hepatic artery: Initial experience in orthotopic liver transplantation candidates

    Energy Technology Data Exchange (ETDEWEB)

    Xu Pengju [Department of Radiology, Zhongshan Hospital, Fudan University, 180 Fenglin Road, Shanghai (China)]. E-mail: xpjbfc@163.com; Yan Fuhua [Department of Radiology, Zhongshan Hospital, Fudan University, 180 Fenglin Road, Shanghai (China)]. E-mail: yanfuhua@yahoo.com; Wang Jianhua [Department of Radiology, Zhongshan Hospital, Fudan University, 180 Fenglin Road, Shanghai (China); Lin Jiang [Department of Radiology, Zhongshan Hospital, Fudan University, 180 Fenglin Road, Shanghai (China); Fan Jia [Liver Cancer Institute, Zhongshan Hospital, Fudan University, 180 Fenglin Road, Shanghai (China)

    2007-03-15

    Objective: To evaluate feasibility of using GRAPPA to acquire high-resolution 3D contrast-enhanced MR angiography (CE-MRA) of hepatic artery and value of GRAPPA for displaying vessels anatomy. Materials and methods: High-resolution CE-MRA using GRAPPA was performed in 67 orthotopic liver transplantation recipient candidates. Signal intensity (SI) and relative SI, i.e., Cv-ro (vessel-to-liver contrast) of the aorta and the hepatic common artery (HCA), were measured. The SI and the relative SI were compared and analyzed using T-test. For purpose of qualitative evaluation, the vessel visualization quality and the order of depicted hepatic artery branches were evaluated by two radiologists independently and assessed by weighted kappa analysis. The depiction of hepatic arterial anatomy and variations was evaluated, and results were correlated with the findings in surgery. Results: The mean SI values were 283.29 {+-} 65.07 (mean {+-} S.D.) for aorta and 283.16 {+-} 64.07 for HCA, respectively. The mean relative SI values were 0.698 {+-} 0.09 for aorta and 0.696 {+-} 0.09 for HCA, respectively. Homogeneous enhancement between aorta and HCA was confirmed by statistically insignificant differences (p-values were 0.89 for mean SI values and 0.12 for mean relative SI values, respectively). The average score for vessel visualization ranged from good to excellent for different artery segments. Overall interobserver agreement in the visualization of different artery segments was excellent (kappa value > 0.80). The distal intrahepatic segmental arteries were well delineated for majority of patients with excellent interobserver agreement. Normal hepatic arterial anatomy was correctly demonstrated in 53 patients, and arterial anomalies were accurately detected on high-resolution MRA image of all 14 patients. Conclusion: High-resolution hepatic artery MRA acquired using GRAPPA in a reproducible manner excellently depicts and delineates small vessels and can be routinely used for

  9. Relationship between retinal blood flow and arterial oxygen.

    Science.gov (United States)

    Cheng, Richard W; Yusof, Firdaus; Tsui, Edmund; Jong, Monica; Duffin, James; Flanagan, John G; Fisher, Joseph A; Hudson, Chris

    2016-02-01

    Vascular reactivity, the response of the vessels to a vasoactive stimulus such as hypoxia and hyperoxia, can be used to assess the vascular range of adjustment in which the vessels are able to compensate for changes in PO2. Previous studies in the retina have not accurately quantified retinal vascular responses and precisely targeted multiple PaO2 stimuli at the same time as controlling the level of carbon dioxide, thus precluding them from modelling the relationship between retinal blood flow and oxygen. The present study modelled the relationship between retinal blood flow and PaO2, showing them to be a combined linear and hyperbolic function. This model demonstrates that the resting tonus of the vessels is at the mid-point and that they have great vascular range of adjustment, compensating for decreases in oxygen above a PETCO2 of 32-37 mmHg but being limited below this threshold. Retinal blood flow (RBF) increases in response to a reduction in oxygen (hypoxia) but decreases in response to increased oxygen (hyperoxia). However, the relationship between blood flow and the arterial partial pressure of oxygen has not been quantified and modelled in the retina, particularly in the vascular reserve and resting tonus of the vessels. The present study aimed to determine the limitations of the retinal vasculature by modelling the relationship between RBF and oxygen. Retinal vascular responses were measured in 13 subjects for eight different blood gas conditions, with the end-tidal partial pressure of oxygen (PETCO2) ranging from 40-500 mmHg. Retinal vascular response measurements were repeated twice; using the Canon laser blood flowmeter (Canon Inc., Tokyo, Japan) during the first visit and using Doppler spectral domain optical coherence tomography during the second visit. We determined that the relationship between RBF and PaO2 can be modelled as a combination of hyperbolic and linear functions. We concluded that RBF compensated for decreases in arterial oxygen content

  10. Comparison of CT during arterial portography, delayed iodine CT, and MR imaging for the preoperative evaluation of hepatic tumors

    International Nuclear Information System (INIS)

    Nelson, R.C.; Chezmar, J.L.; Sugarbaker, P.H.; Bernardino, M.E.

    1988-01-01

    Twenty-eight patients with neoplastic involvement of the liver were studied with CT during arterial portography, delayed iodine CT, and MR imaging, to determine the number, size, and location of focal hepatic lesions prior to hepatic tumor surgery. The MR pulse-sequences used included T1- and T2-weighted spin-echo (SE) sequences and inversion-recovery (IR) sequences at 0.5 T, 1.5 T, or both. Results were compared with operative and pathologic findings. The sensitivities for the detection of individual focal lesions are as follows: CT during arterial portography, delayed iodine CT, 77%, IR at 0.5 T, 74%; T1-weighted SE at 0.5 T, 69%; T2-weighted SE at 1.5 T, 55%, IR at 1.5 T, 50%; T2-weighted SE at 0.5 T, 48%, and T1-weighted SE at 1.5 T, 31%. The positive predictive values ranged from 88% to 100% for all techniques. The authors' data suggest that CT during arterial portography is a superior technique for evaluating patients prior to hepatic tumor surgery

  11. Heavy flow autochtonic case of hepatitis E in elderly men

    Directory of Open Access Journals (Sweden)

    S. V. Baramzina

    2016-01-01

    Full Text Available The article presents an analysis of the first clinical cases of acute hepatitis E autochtonic on the territory of the Kirov region. HEV-infection was diagnosed in 76 year old male, not to travel outside the region and the country for a long time, eat a lot of fresh fruit. A feature of the disease in non-endemic region was: severe course of hepatitis E in the elderly, with the development of clinic of acute liver failure and encephalopathy, the presence of the expressed syndrome cytolysis, cholestasis, hepatic-cell failure.Timely treatment of a patient for medical care, the lack of severe somatic diseases, chronic liver disease and adequate pathogenetic therapy helped to keep the patient’s life. In deciphering undifferentiated acute hepatitis in the elderly should be included in the scheme of examination and determination HEV RNA, a/HEV IgM and G.

  12. Clinical study of color Doppler sonography in Graves' disease blood flow changes after thyroid arteries embolization

    International Nuclear Information System (INIS)

    Zhuang Wenquan; Li Weiduo; Yang Jianyong; Chen Wei; Huang Yonghui; Guo Wenbo; Li Jiaping

    2003-01-01

    Objective: To study the color doppler image characteristics of thyroid arteries pre- and post-interventional procedure and to assess the clinical efficacy in Gnaves' disease. Methods: 11 from 31 patients diagnosed as Graves' disease undertaken thyroid arteries embolization, were analyzed. Color Doppler sonography was applied to monitor the pre-and post- procedure thyroid size and diameters of thyroid arteries. Power Doppler was used to detect the Vmax, Vmin, RI and blood flow. Results: After thyroid arteries embolization, the size and vascularity of thyroids were reduced. The thyroid arteries showed shrinkage and stoppage blood flow at the embolized site. The changes of RI, blood parameters of Vmax, Vmin and diameters of the thyroid arteries pre- and post-procedure turned out to be statistically significant for clinical restriction. Conclusion: The color Doppler sonography plays an important role for preoperative diagnosis and predicting the prognosis

  13. Blood flows in the maxillocarotid anastomoses and internal carotid artery of conscious dogs.

    Science.gov (United States)

    Lee, M C; Reid, I A; Ramsay, D J

    1986-06-01

    Although the external carotid artery is known to contribute to the cerebral blood flow in anesthetized dogs, quantitative information on the anastomoses and their role in conscious dogs is lacking. This study was carried out to determine blood flows in these anastomoses and the internal carotid artery, and also to examine the functional significance of the anastomoses in conscious dogs. Fifteen-micron radioactive microspheres were injected into common and external carotid arteries of four conscious dogs through chronically implanted catheters. Blood flows were determined by the reference sample method and by comparing microsphere distributions in the brain and the masseter muscle. Blood flows were estimated to be 140 +/- 32, 7.7 +/- 1.4, and 3.3 +/- 1.1 ml/minute (mean +/- SD) in the common carotid artery, internal carotid artery, and anastomoses on each side, respectively. Additional evidence indicated that the anastomotic flow so determined was primarily the flow in the anastomotic artery. Humoral responses to angiotensin II infusions were also studied in conscious dogs. External carotid angiotensin increased plasma 11-hydroxycorticosteroid concentration (used as an index of ACTH secretion) but did not increase plasma vasopressin concentration to the same extent as common carotid infusion. Therefore, the external carotid artery is functionally important in perfusing the brain in conscious dogs.

  14. Axial flow velocity patterns in a normal human pulmonary artery model: pulsatile in vitro studies.

    Science.gov (United States)

    Sung, H W; Yoganathan, A P

    1990-01-01

    It has been clinically observed that the flow velocity patterns in the pulmonary artery are directly modified by disease. The present study addresses the hypothesis that altered velocity patterns relate to the severity of various diseases in the pulmonary artery. This paper lays a foundation for that analysis by providing a detailed description of flow velocity patterns in the normal pulmonary artery, using flow visualization and laser Doppler anemometry techniques. The studies were conducted in an in vitro rigid model in a right heart pulse duplicator system. In the main pulmonary artery, a broad central flow field was observed throughout systole. The maximum axial velocity (150 cm s-1) was measured at peak systole. In the left pulmonary artery, the axial velocities were approximately evenly distributed in the perpendicular plane. However, in the bifurcation plane, they were slightly skewed toward the inner wall at peak systole and during the deceleration phase. In the right pulmonary artery, the axial velocity in the perpendicular plane had a very marked M-shaped profile at peak systole and during the deceleration phase, due to a pair of strong secondary flows. In the bifurcation plane, higher axial velocities were observed along the inner wall, while lower axial velocities were observed along the outer wall and in the center. Overall, relatively low levels of turbulence were observed in all the branches during systole. The maximum turbulence intensity measured was at the boundary of the broad central flow field in the main pulmonary artery at peak systole.

  15. Estimation of the flow resistances exerted in coronary arteries using a vessel length-based method.

    Science.gov (United States)

    Lee, Kyung Eun; Kwon, Soon-Sung; Ji, Yoon Cheol; Shin, Eun-Seok; Choi, Jin-Ho; Kim, Sung Joon; Shim, Eun Bo

    2016-08-01

    Flow resistances exerted in the coronary arteries are the key parameters for the image-based computer simulation of coronary hemodynamics. The resistances depend on the anatomical characteristics of the coronary system. A simple and reliable estimation of the resistances is a compulsory procedure to compute the fractional flow reserve (FFR) of stenosed coronary arteries, an important clinical index of coronary artery disease. The cardiac muscle volume reconstructed from computed tomography (CT) images has been used to assess the resistance of the feeding coronary artery (muscle volume-based method). In this study, we estimate the flow resistances exerted in coronary arteries by using a novel method. Based on a physiological observation that longer coronary arteries have more daughter branches feeding a larger mass of cardiac muscle, the method measures the vessel lengths from coronary angiogram or CT images (vessel length-based method) and predicts the coronary flow resistances. The underlying equations are derived from the physiological relation among flow rate, resistance, and vessel length. To validate the present estimation method, we calculate the coronary flow division over coronary major arteries for 50 patients using the vessel length-based method as well as the muscle volume-based one. These results are compared with the direct measurements in a clinical study. Further proving the usefulness of the present method, we compute the coronary FFR from the images of optical coherence tomography.

  16. Ideal Internal Carotid Artery Trapping Technique without Bypass in a Patient with Insufficient Collateral Flow

    OpenAIRE

    Chung, Joon Ho; Shin, Yong Sam; Lim, Yong Cheol; Park, Minjung

    2009-01-01

    Internal carotid artery (ICA) trapping can be used for treating intracranial giant aneurysm, blood blister-like aneurysms and ICA rupture during the surgery. We present a novel ICA trapping technique which can be used with insufficient collaterals flow via anterior communicating artery (AcoA) and posterior communicating artery (PcoA). A patient was admitted with severe headache and the cerebral angiography demonstrated a typical blood blister-like aneurysm at the contralateral side of PcoA. F...

  17. Experiment of embolizing hepatocarcinoma with heated lipiodol via hepatic artery in VX2 rabbit model

    International Nuclear Information System (INIS)

    Cao Wei; Wang Zhimin; Zhang Hongxin; Wan Yi

    2006-01-01

    Objective: To evaluate the anti-tumour effect of 60 degree C Lipiodol in the embolization of VX 2 hepatocarcinoma in rabbits. Methods: VX 2 carcinoma cells were surgically implanted into the left liver lobe in 30 male New Zealand white rabbits, which were randomly divided into 3 groups by figure and table method with 10 rabbits in each group. Physiological saline, Lipiodol (37 degree C), and Lipiodol (60 degree C) were injected in each group via hepatic artery and liver cancer was embolized. The volume of tumour and serum level of aspartate aminotransferase (AST) were observed after one week, and the survival period of VX 2 rabbits was also observed. Results: In the group of Lipiodol (60 degree C), the growth rate of tumour (0.92± 0.21) was significantly lower than that of control group (3.48±) and Lipiodol (37 degree C) groups (1.69±0.26), respectively (F=34.95, P 0.05), but was significantly higher than the control group (68.6±6.6) U/L (t=19.24, P<0.05). Conclusion: Lipiodol (60 degree C) greatly decreases the tumour's growth rate and prolongs the survival period. It is a safe method and has stronger inhibitory effect than other groups. (authors)

  18. Evaluation of long-term effect of hepatic arterial embolization with pingyangmycin-lipiodol emulsion in patients with hepatic cavernous hemangiomas

    International Nuclear Information System (INIS)

    Zhang Xuejun; Ouyang Yong; Ma Heping; Chao Lumeng; Zhen Yanli; Gu Subin; Zhou Qunhui; Liu Pengzhi; Wang Hong

    2010-01-01

    Objective: To evaluate the long-term effect of hepatic arterial embolization with pingyanmycin-lipiodol emulsion (PLE) in patients with cavernous hemangiomas of the liver (CHL) and its influence factors. Methods: One hundred and fifty-six hemangiomas that were diagnosed by imaging examinations or confirmed pathologically by surgery in 105 patients with integral follow-up data were analyzed retrospectively in this paper. All hemangiomas were divided into 4 groups according to their size (the largest size of hemangioma) by the authors as follows: A group (≤3 cm, n=25); B group (>3 cm and 2 test respectively. And the influence factors, included of the variant size of hemangiomas, abundant or sparse of abnormal sinusoids and the number of treatment procedures, were also analyzed respectively. Results: The total effective rate of the 156 hemangiomas in 105 patients was 92.95% (145/156). After single procedure of hepatic arterial embolization with PLE, the total effective rate of A and B groups were 100% (57/57), that of C and D groups were 85.86% (85/99), and the difference reach significant (X 2 =8.8553, P 2 =5.2642, P<0.05) than those of group with single procedure (72.73%, 8/11). Conclusions: A best long-term curative effect (complete cure) is usually obtained in the small hemangiomas with abundant abnormal sinusoids, and a satisfactory long-term curative effect can also be achieved in the larger or multiple hemangiomas, particularly in those hemangiomas with abundant abnormal sinusoids by using the repeat procedures of hepatic arterial embolization with PLE. (authors)

  19. 3D Heart Model and 4D Flow MRI 20 Years after Spiral Arterial Switch Operation.

    Science.gov (United States)

    Sievers, Hans-Hinrich; Kheradvar, Arash; Kramer, Hans-Heiner; Rickers, Carsten

    2016-12-01

    Case of a patient is presented here 20 years after spiral direct anastomosis of the great arteries in an arterial switch operation. Three-dimensional model of the heart combined with four-dimensional flow magnetic resonance imaging presents a novel comprehensive way to assess surgical results.

  20. Measurement of blood flow in the carotid arteries using color doppler in healthy Korean adults

    International Nuclear Information System (INIS)

    Moon, Ki Ho; Jeon, Do Ig; Choi, Chang Ho; Ro, Young Jin; Kim, Hak Jin; Lee, Suck Hong; Kim, Byung Soo

    1994-01-01

    To evaluate the blood flow patterns and velocities of the carotid arteries in healthy Korean adults. We evaluated the blood flow patterns and measured the peak systolic and end-diastolic velocities of the common, internal and external carotid arteries in 48 healthy adults who did not have cardiovascular disorders and neck lesions. The velocity difference was analyzed according to different age groups. In addition, peak systolic and end-diastolic velocity ratio of the internal to common carotid artery was estimated, and our data were compared with values reported by other authors. Generally, the velocity in the younger age group tends be to higher than in older group. The peak systolic and end diastolic velocities of the internal carotid artery were 84.5 cm/sec and 30.5 cm/sec. The peak systolic and end diastolic velocity ratio of the internal to common carotid artery were 0.715 and 0.966. The internal carotid artery was less resistant in blood flow than the external carotid artery. Our data were lower than the values which were reported by Bluth et al. The blood flow velocities of the internal carotid artery in healthy adults were lower than those of previous reported foreign values, but the patterns were similar

  1. Comparison of radial 4D Flow-MRI with perivascular ultrasound to quantify blood flow in the abdomen and introduction of a porcine model of pre-hepatic portal hypertension.

    Science.gov (United States)

    Frydrychowicz, A; Roldan-Alzate, A; Winslow, E; Consigny, D; Campo, C A; Motosugi, U; Johnson, K M; Wieben, O; Reeder, S B

    2017-12-01

    Objectives of this study were to compare radial time-resolved phase contrast magnetic resonance imaging (4D Flow-MRI) with perivascular ultrasound (pvUS) and to explore a porcine model of acute pre-hepatic portal hypertension (PHTN). Abdominal 4D Flow-MRI and pvUS in portal and splenic vein, hepatic and both renal arteries were performed in 13 pigs of approximately 60 kg. In six pigs, measurements were repeated after partial portal vein (PV) ligature. Inter- and intra-reader comparisons and statistical analysis including Bland-Altman (BA) comparison, paired Student's t tests and linear regression were performed. PvUS and 4D Flow-MRI measurements agreed well; flow before partial PV ligature was 322 ± 30 ml/min in pvUS and 297 ± 27 ml/min in MRI (p = 0.294), and average BA difference was 25 ml/min [-322; 372]. Inter- and intra-reader results differed very little, revealed excellent correlation (R 2  = 0.98 and 0.99, respectively) and resulted in BA differences of -5 ml/min [-161; 150] and -2 ml/min [-28; 25], respectively. After PV ligature, PV flow decreased from 356 ± 50 to 298 ± 61 ml/min (p = 0.02), and hepatic arterial flow increased from 277 ± 36 to 331 ± 65 ml/min (p = n.s.). The successful in vivo comparison of radial 4D Flow-MRI to perivascular ultrasound revealed good agreement of abdominal blood flow although with considerable spread of results. A model of pre-hepatic PHTN was successfully introduced and acute responses monitored. • Radial 4D Flow-MRI in the abdomen was successfully compared to perivascular ultrasound. • Inter- and intra-reader testing demonstrated excellent reproducibility of upper abdominal 4D Flow-MRI. • A porcine model of acute pre-hepatic portal hypertension was successfully introduced. • 4D Flow-MRI successfully monitored acute changes in a model of portal hypertension.

  2. Ultrasonographic Measurement of the Diameter of a Normal Bile Duct, Hepatic Artery and Portal Vein in Infants Younger Than 3 Months

    International Nuclear Information System (INIS)

    Kim, Sang Yoon; Lee, Young Seok

    2009-01-01

    This study focused on measuring the diameter of the normal bile duct, hepatic artery and portal vein with high resolution US in infants younger than 3 months, and we wanted to determine the relative ratio of these diameters. Fifty US examinations were performed on infants younger than 3 months and who did not have any clinical or laboratory abnormality associated with the hepatobiliary system. We measured the diameter of the bile duct, hepatic artery and portal vein at the level of the portal vein bifurcation with using 17-5 MHz US and we determined the relative ratios of these diameters. To evaluate the statistical difference in the diameter of the bile duct, hepatic artery and portal vein, we performed one-way ANOVA and Scheffe's multiple comparison test. To determine the relative ratio of these diameters, the ratio of the bile duct to the hepatic artery was defined as the hepatic artery/bile duct, the ratio of the hepatic artery to the portal vein was defined as the portal vein/hepatic artery and the ratio of the bile duct to the portal vein was defined as the portal vein/bile duct. We calculated the averages ± standard deviations of this data (minimum ∼ maximum). In all fifty infants, the bile duct, hepatic artery and portal vein were detectable and measurable. The average diameter of a bile duct was 0.85 ± 0.19 mm (0.56 ∼ 1.47 mm), it was 1.33 ± 0.31 mm (0.90 ∼ 2.37 mm) for the hepatic artery and 3.32 ± 0.68 mm (2.06 ∼ 5.08 mm) for the portal vein. The diameter of these structures was significantly different from each other according to one-way ANOVA (p < 0.001). The average diameter of the hepatic artery was significantly larger than that of the bile duct and the average diameter of the portal vein was significantly larger than that of bile duct and hepatic artery on Scheffe's multiple comparison test. The relative ratio of the bile duct to the hepatic artery was 1.60 ± 0.41 (0.77 ∼ 2.66), that of the hepatic artery to the portal vein was 2

  3. CT arteriography via the right inferior phrenic artery developed parasitic perfusion into the liver

    International Nuclear Information System (INIS)

    Inaba, Yoshitaka; Arai, Yasuaki; Sueyoshi, Satoshi; Yamagami, Takuji; Aramaki, Takeshi; Yamaura, Hidekazu; Matsueda, Kiyoshi; Sasaki, Fumio; Takeuchi, Yoshihito.

    1998-01-01

    The distribution of arterial blood flow via the right inferior phrenic artery (rt-IPA) developing parasitic perfusion into the liver was evaluated by CT arteriography (CTA) in 50 cases with hepatic tumors. In all cases, CTA via rt-IPA showed hyperperfusion area including hepatic tumors in the posterior segment and the caudate lobe of the liver, and adding the left hepatic lobe in cases with hepatic arterial occlusion. In 82% of 33 cases obtained both CTA via rt-IPA and CTA via hepatic artery, the hyperperfusion area on CTA via rt-IPA exactly corresponded to perfusion defect area on CTA via hepatic artery. CTA was much useful for understanding hemodynamics in cases with parasitic perfusion into the liver and it could make transcatheter arterial therapy more effective. (author)

  4. CT arteriography via the right inferior phrenic artery developed parasitic perfusion into the liver

    Energy Technology Data Exchange (ETDEWEB)

    Inaba, Yoshitaka; Arai, Yasuaki; Sueyoshi, Satoshi; Yamagami, Takuji; Aramaki, Takeshi; Yamaura, Hidekazu; Matsueda, Kiyoshi; Sasaki, Fumio [Aichi Cancer Center, Nagoya (Japan); Takeuchi, Yoshihito

    1998-02-01

    The distribution of arterial blood flow via the right inferior phrenic artery (rt-IPA) developing parasitic perfusion into the liver was evaluated by CT arteriography (CTA) in 50 cases with hepatic tumors. In all cases, CTA via rt-IPA showed hyperperfusion area including hepatic tumors in the posterior segment and the caudate lobe of the liver, and adding the left hepatic lobe in cases with hepatic arterial occlusion. In 82% of 33 cases obtained both CTA via rt-IPA and CTA via hepatic artery, the hyperperfusion area on CTA via rt-IPA exactly corresponded to perfusion defect area on CTA via hepatic artery. CTA was much useful for understanding hemodynamics in cases with parasitic perfusion into the liver and it could make transcatheter arterial therapy more effective. (author)

  5. Comparative study of Newtonian physiological blood flow through normal and stenosed carotid artery

    Science.gov (United States)

    Rahman, Mohammad Matiur; Hossain, Md. Anwar; Mamun, Khairuzzaman; Akhter, Most. Nasrin

    2017-06-01

    A numerical simulation is performed to investigate Newtonian physiological flows behavior on three dimensional idealized carotid artery (CA) and single stenosed (75% by area) carotid artery(SCA). The wall vessel is set as rigid during simulation. Bifurcated blood vessel are simulated by using three-dimensional flow analysis. Physiological and parabolic velocity profiles are set out to fix the conditions of inlet boundaries of artery. In other hand, physiological waveform is an important part of compilation and it is successfully done by utilization of Fourier series having sixteen harmonics. The investigation has a Reynolds number range of 94 to 1120. Low Reynolds number k — ω model has been used as governing equation. The investigation has been carried out to characterize the flow behavior of blood in two geometry, namely, (i) Normal carotid artery (CA) and (ii) Stenosed carotid artery (SCA). The Newtonian model has been used to study the physics of fluid. The findings of the two models are thoroughly compared in order to observe there behavioral sequence of flows. The numerical results were presented in terms of velocity, pressure, wall shear stress distributions and cross sectional velocities as well as the streamlines contour. Stenosis disturbs the normal pattern of blood flow through the artery as reduced area. At stenosis region velocity and peak Reynolds number rapidly increase and Reynolds number reach transitional and turbulent region. These flow fluctuation and turbulence have bad effect to the blood vessel which makes to accelerate the progress of stenosis.

  6. Normal reference values for vertebral artery flow volume by color Doppler sonography in Korean adults

    International Nuclear Information System (INIS)

    Hong, Hyun Sook; Cha, Jang Gyu; Park, Seong Jin; Joh, Joon Hee; Park, Jai Soung; Kim, Dae Ho; Lee, Hae Kyung; Ahn, Hyun Cheol

    2003-01-01

    Vertebrobasilar ischemia has been attributed to a reduction of net vertebral artery flow volume. This study was to establish the reference values for the flow volume of the vertebral artery using color Doppler sonography in the normal Korea adults. Thirty five normal Korea adults without any underlying disease including hypertension, hyperlipidemia, diabetes, heart disease, obesity (body mas index>30), or carotid artery stenosis was included. There were 17 males and 18 females, age ranged from 20 to 53 years (average=32.86 years). Flow velocities and vessel diameters were recorded in the intertransverse (V2) segment, usually at C5-6 level, bilaterally. The flow volume (Q) was calculated. (Q=time averaged mean velocity x cross sectional area of vessel) A lower Flow velocity and smaller vessel diameter were measured on the right side compared to those of the left side, resulting in a lower flow volume. The calculated flow volumes using the equation were 77.0 ± 39.7 ml/min for the right side and 127.6 ± 71.0 ml/min for the left side (p=0.0001) while the net vertebral artery flow volume was 204.6 ± 81.8 ml/min. Decrease in the vertebral artery flow volume was statistically significant with advanced age. (r=-0.36, p=0.032). Vertebral artery blood flow volume was 191.20 ± 59.19 ml/min in male, and 217.28 ± 98.67 ml/min in female (p=0.6). The normal range for the net vertebral artery flow volume defined by the 5th to 95th percentiles was between 110.06 and 364.1 ml/min. The normal range for the net vertebral artery flow volume was between 110.06 and 364.1 ml/min. Vertebral artery flow volume decreased with the increase of age. However, gender did not affect the blood flow volume.

  7. Clinical observations on the effect of carotid artery occlusion on cerebral blood flow mapped by xenon computed tomography and its correlation with carotid artery back pressure

    International Nuclear Information System (INIS)

    Steed, D.L.; Webster, M.W.; DeVries, E.J.; Jungreis, C.A.; Horton, J.A.; Sehkar, L.; Yonas, H.

    1990-01-01

    Xenon computed tomographic cerebral blood flow mapping was correlated with internal carotid artery stump pressures and clinical neurologic assessment during temporary internal carotid artery occlusion. One hundred fourteen patients with skull base tumors or intracranial aneurysms potentially requiring carotid resection or ligation underwent angiography, xenon CT cerebral blood flow mapping, and internal carotid artery blood pressure monitoring. The internal carotid artery was then temporarily occluded with a balloon catheter, stump pressure was measured through the catheter, and the xenon CT cerebral blood flow mapping was repeated. Adequate xenon CT cerebral blood flow was defined as greater than 30 cc/100 gm/min. All patients had normal xenon CT cerebral blood flow before internal carotid artery occlusion. During internal carotid artery occlusion, xenon CT cerebral blood flow was found to be normal (group I, 40 patients), globally reduced but still within the normal range (group II, 50 patients), or low in the distribution of the ipsilateral middle cerebral artery (group III, 13 patients). With balloon occlusion, an immediate neurologic deficit developed in 11 patients (9%) requiring deflation of the balloon preceding xenon CT cerebral blood flow measurement (group IV). In group I internal carotid artery blood pressure was 128 mm Hg. (range 85 to 171 mm Hg) with stump pressure 86 mm Hg (range 46 to 125 mm Hg). In group II internal carotid artery blood pressure was 130 mm Hg. (range 78 to 199 mm Hg), with stump pressure 86 mm Hg (range 31 to 150 mm Hg)

  8. Investigation of spiral blood flow in a model of arterial stenosis

    OpenAIRE

    Paul, M.C.; Larman, A.

    2009-01-01

    The spiral component of blood flow has both beneficial and detrimental effects in human circulatory system [Stonebridge PA, Brophy CM. Spiral laminar flow in arteries? Lancet 1991; 338: 1360–1]. We investigate the effects of the spiral blood flow in a model of three-dimensional arterial stenosis with a 75% cross-sectional area reduction at the centre by means of computational fluid dynamics (CFD) techniques. The standard κ–ω model is employed for simulation of the blood flow for the...

  9. Recirculation zone length in renal artery is affected by flow spirality and renal-to-aorta flow ratio.

    Science.gov (United States)

    Javadzadegan, Ashkan; Fulker, David; Barber, Tracie

    2017-07-01

    Haemodynamic perturbations such as flow recirculation zones play a key role in progression and development of renal artery stenosis, which typically originate at the aorta-renal bifurcation. The spiral nature of aortic blood flow, division of aortic blood flow in renal artery as well as the exercise conditions have been shown to alter the haemodynamics in both positive and negative ways. This study focuses on the combinative effects of spiral component of blood flow, renal-to-aorta flow ratio and the exercise conditions on the size and distribution of recirculation zones in renal branches using computational fluid dynamics technique. Our findings show that the recirculation length was longest when the renal-to-aorta flow ratio was smallest. Spiral flow and exercise conditions were found to be effective in reducing the recirculation length in particular in small renal-to-aorta flow ratios. These results support the hypothesis that in renal arteries with small flow ratios where a stenosis is already developed an artificially induced spiral flow within the aorta may decelerate the progression of stenosis and thereby help preserve kidney function.

  10. A new therapeutic assessment score for advanced hepatocellular carcinoma patients receiving hepatic arterial infusion chemotherapy.

    Directory of Open Access Journals (Sweden)

    Issei Saeki

    Full Text Available Hepatic arterial infusion chemotherapy (HAIC is an option for treating advanced hepatocellular carcinoma (HCC. Because of the poor prognosis in HAIC non-responders, it is important to identify patients who may benefit from continuous HAIC treatment; however, there are currently no therapeutic assessment scores for this identification. Therefore, we aimed to establish a new therapeutic assessment score for such patients.We retrospectively analyzed 90 advanced HCC patients with elevated baseline alpha-fetoprotein (AFP and/or des-gamma-carboxy prothrombin (DCP levels and analyzed various parameters for their possible use as predictors of response and survival. AFP and DCP responses were assessed after half a course of HAIC (2 weeks; a positive-response was defined as a reduction of ≥ 20% from baseline.Multivariate analysis identified DCP response (odds ratio 16.03, p < 0.001 as an independent predictor of treatment response. In multivariate analysis, Child-Pugh class A (hazard ratio [HR] 1.99, p = 0.018, AFP response (HR 2.17, p = 0.007, and DCP response (HR 1.90, p = 0.030 were independent prognostic predictors. We developed an Assessment for Continuous Treatment with HAIC (ACTH score, including the above 3 factors, which ranged from 0 to 3. Patients stratified into two groups according to this score showed significantly different prognoses (≤ 1 vs. ≥ 2 points: median survival time, 15.1 vs. 8.7 months; p = 0.003.The ACTH score may be useful in the therapeutic assessment of HCC patients receiving HAIC.

  11. [Usefulness of arterial calcium stimulation with hepatic venous sampling in the localization diagnosis of endogenous hyperinsulinism].

    Science.gov (United States)

    Moreno Moreno, Paloma; Gutiérrez Alcántara, Carmen; Muñoz-Villanueva, María Del Carmen; Ortega, Rafael Palomares; Corpas Jiménez, María del Sierra; Zurera Tendero, Luis; Benito López, Pedro

    2010-03-01

    The aim of this study was to assess the utility of arterial calcium stimulation with hepatic venous sampling (ASVS) in the localization of tumors in patients with endogenous hyperinsulinism not detected with other methods. We performed a retrospective study of 26 patients admitted to our hospital for hypoglycemia who underwent ASVS because the source of hyperinsulinism was not clearly identified by other imaging techniques. The histopathological result in patients who underwent a surgical procedure was considered the reference for statistical study of the accuracy of this technique. Statistical analysis was performed by comparing proportions with the chi-squared test with Yates' correction for contingency tables, and Cohen's kappa coefficient as a measure of interrater agreement between two observations. Surgery was performed in 17 patients, 13 with positive ASVS and the remaining four with negative results. An insulinoma was removed in 12 patients, and 10 of these were detected in the ASVS. A total of 76.9 % of positive ASVS tests corresponded to a histological diagnosis of insulinoma, and 83% of these insulinomas were positive in ASVS. This association was statistically significant (chi cuadrado=7.340; p=0.012). Two of three patients with nesidioblastosis had a positive response in the ASVS. A good and statistically significant agreement was obtained between histopathologic diagnosis and ASVS results (kappa=0.556, p = 0.007). ASVS is a useful procedure in the localization diagnosis of endogenous hyperinsulinism not detected by other imaging tests. This technique allows tumors in the pancreatic gland to be identified and may be useful in the choice of the surgical technique to be used. Copyright 2009 SEEN. Published by Elsevier Espana. All rights reserved.

  12. Determination of hepatic blood flow through radioactive colloidal gold in congestive heart foilure

    International Nuclear Information System (INIS)

    Papaleo Netto, M.; Carvalho, N.; Carvalho Filho, E.T.; Forti, N.A.; Giannini, S.D.; Diament, J.; Decourt, L.V.; Chiaverini, R.

    1974-01-01

    Hepatic blood flow as derermined by radioactive colloidal gold and its correlation with total blood valume are studied in 13 patients with predominantly right-side congestive heart failure. During the phase of cardiac compensation, the following events occur: 1) significant decrease of the half-life of the clearance of radioactive colloidal gold and of the total blood volume; 2) increase of the clearance constant of the radioactive substance and of hepatic blood flow; 3) significantion correlation between the clearance constant and the total blood volume [pt

  13. Experimental study on representation of flow on the bifurcated carotid arterial phantoms using magnetic resonance angiography

    International Nuclear Information System (INIS)

    Chung, Tae Sub; Rhim, Yoon Chul; Kim, Kyung Oh; Suh, Sang Ho; Jin, En Hao

    1995-01-01

    A common finding of carotid artery on magnetic resonance angiograms(MRAs) is a signal dropout along the posterior wall of carotid bulb due to reverse flow. The purpose of this study is to evaluate variable flow patterns on bifurcated carotid arterial phantoms using steady-state flow. We designed phantoms of a bifurcated carotid artery with acrylic materials. Flow patterns were evaluated with axial and coronal imaging of MRA(2D-TOF, 3D-TOF), color Doppler imaging, and computational fluid dynamics (CFD) within the phantoms constructed of an automated closed-type circulatory system filled with 4% sugar solution. These findings were compared with findings obtained from normal volunteers. Axial 3D-TOF MRA images exhibited closer resemblance to the contour of the inner wall of phantoms when compared to coronal 2D-TOF MRA imaging. However, 2D-TOF MRA showed good contrast difference of signal intensities between forward flow area and reverse flow area. Dark zones with reduced signal intensities due to reversed flow were separated from the outer wall of the internal and external carotid arteries by a thin layer of forward flow along the wall on the source slice image of MRA. The general hemodynamics of the phantoms on MRA were identical to hemodynamics on color Doppler imaging and CFD. The results obtained with the phantoms matched the findings on normal volunteers. Although representations of bifurcated carotid arterial phantoms on axial 3D-TOF MRA were excellent if ideally designed, the zone of reversed flow could be a significant factor in creating distorted image when the zone of reversed flow contacted directly with curved or deformed arterial wall

  14. [11C]palmitate kinetics across the splanchnic bed in arterial, portal and hepatic venous plasma during fasting and euglycemic hyperinsulinemia

    International Nuclear Information System (INIS)

    Guiducci, Letizia; Jaervisalo, Mikko; Kiss, Jan; Nagren, Kjell; Viljanen, Antti; Naum, Alexandru G.; Gastaldelli, Amalia; Savunen, Timo; Knuuti, Juhani; Salvadori, Piero A.; Ferrannini, Ele; Nuutila, Pirjo; Iozzo, Patricia

    2006-01-01

    Purpose: The liver is fundamental in regulating lipid metabolism, and it supplies fatty acids (FA) to the rest of the body in the form of triglycerides (TG); the time-related relevance of this process is incompletely defined. The aim of the study was to investigate the appearance of labeled TG in the hepatic vascular bed after [ 11 C]palmitate injection during fasting and insulin stimulation. Methods: Plasma [ 11 C]palmitate kinetics in arterial, portal and hepatic venous lipid fractions was studied in eight anesthetized pigs during fasting or euglycemic hyperinsulinemia. Plasma analyses were conducted at 10 and 40 min after tracer injection. Corresponding liver positron emission tomography (PET) images were acquired for the semiquantitative determination of hepatic FA uptake. Results: At 10 min, plasma levels of unchanged [ 11 C]palmitate were lower in hyperinsulinemic than in fasting experiments in the artery and in the portal vein (P≤.03), suggesting faster clearance. Levels of unmetabolized [ 11 C]palmitate did not differ between portal and arterial plasma. In the fasting state, a tendency to a positive arterial and portal vs. hepatic venous gradient was observed, indicative of net hepatic [ 11 C]palmitate extraction. Labeled TG were already detectable at 10 min (fasting vs. hyperinsulinemia, ns) and were higher in fasting than in hyperinsulinemic animals at 40 min (92±1% and 82±6% of arterial plasma radioactivity). Higher proportions of labeled TG were recovered in portal vein plasma, suggesting release by the gut. The portal and the arterial-portal vs. hepatic venous TG gradient tended to be positive. Accordingly, hepatic FA uptake was higher, but declined more rapidly during fasting than during hyperinsulinemia. Conclusion: The study indicates that the redistribution of [ 11 C]palmitate between different lipid pools occurs within the short time interval of most PET experiments and is strongly influenced by insulin. Labeled TG constitute an additional

  15. [{sup 11}C]palmitate kinetics across the splanchnic bed in arterial, portal and hepatic venous plasma during fasting and euglycemic hyperinsulinemia

    Energy Technology Data Exchange (ETDEWEB)

    Guiducci, Letizia [SSSUP Medical Sciences Branch, Pisa 56100 (Italy); Turku PET Centre, University of Turku, Turku 20520 (Finland); PET Centre, Institute of Clinical Physiology, CNR National Research Council, 56100 Pisa (Italy); Jaervisalo, Mikko [Turku PET Centre, University of Turku, Turku 20520 (Finland); Kiss, Jan [Turku PET Centre, University of Turku, Turku 20520 (Finland); Department of Surgery, University of Turku, Turku 20520 (Finland); Nagren, Kjell [Turku PET Centre, University of Turku, Turku 20520 (Finland); Viljanen, Antti [Turku PET Centre, University of Turku, Turku 20520 (Finland); Naum, Alexandru G. [Turku PET Centre, University of Turku, Turku 20520 (Finland); Gastaldelli, Amalia [PET Centre, Institute of Clinical Physiology, CNR National Research Council, 56100 Pisa (Italy); Savunen, Timo [Department of Surgery, University of Turku, Turku 20520 (Finland); Knuuti, Juhani [Turku PET Centre, University of Turku, Turku 20520 (Finland); Salvadori, Piero A. [PET Centre, Institute of Clinical Physiology, CNR National Research Council, 56100 Pisa (Italy); Ferrannini, Ele [PET Centre, Institute of Clinical Physiology, CNR National Research Council, 56100 Pisa (Italy); Department of Internal Medicine, University of Pisa School of Medicine, Pisa 56100 (Italy); Nuutila, Pirjo [Turku PET Centre, University of Turku, Turku 20520 (Finland); Department of Medicine, University of Turku, Turku 20520 (Finland); Iozzo, Patricia [Turku PET Centre, University of Turku, Turku 20520 (Finland) and PET Centre, Institute of Clinical Physiology, CNR National Research Council, 56100 Pisa (Italy)]. E-mail: patricia.iozzo@ifc.cnr.it

    2006-05-15

    Purpose: The liver is fundamental in regulating lipid metabolism, and it supplies fatty acids (FA) to the rest of the body in the form of triglycerides (TG); the time-related relevance of this process is incompletely defined. The aim of the study was to investigate the appearance of labeled TG in the hepatic vascular bed after [{sup 11}C]palmitate injection during fasting and insulin stimulation. Methods: Plasma [{sup 11}C]palmitate kinetics in arterial, portal and hepatic venous lipid fractions was studied in eight anesthetized pigs during fasting or euglycemic hyperinsulinemia. Plasma analyses were conducted at 10 and 40 min after tracer injection. Corresponding liver positron emission tomography (PET) images were acquired for the semiquantitative determination of hepatic FA uptake. Results: At 10 min, plasma levels of unchanged [{sup 11}C]palmitate were lower in hyperinsulinemic than in fasting experiments in the artery and in the portal vein (P{<=}.03), suggesting faster clearance. Levels of unmetabolized [{sup 11}C]palmitate did not differ between portal and arterial plasma. In the fasting state, a tendency to a positive arterial and portal vs. hepatic venous gradient was observed, indicative of net hepatic [{sup 11}C]palmitate extraction. Labeled TG were already detectable at 10 min (fasting vs. hyperinsulinemia, ns) and were higher in fasting than in hyperinsulinemic animals at 40 min (92{+-}1% and 82{+-}6% of arterial plasma radioactivity). Higher proportions of labeled TG were recovered in portal vein plasma, suggesting release by the gut. The portal and the arterial-portal vs. hepatic venous TG gradient tended to be positive. Accordingly, hepatic FA uptake was higher, but declined more rapidly during fasting than during hyperinsulinemia. Conclusion: The study indicates that the redistribution of [{sup 11}C]palmitate between different lipid pools occurs within the short time interval of most PET experiments and is strongly influenced by insulin. Labeled TG

  16. The relationship between fractional flow reserve, platelet reactivity and platelet leukocyte complexes in stable coronary artery disease

    NARCIS (Netherlands)

    Sels, J.W.E.M.; Rutten, B.; Holten, van T.C.; Hillaert, M.A.K.; Waltenberger, J.; Pijls, N.H.J.; Pasterkamp, G.; Groot, de P.G.; Roest, M.

    2013-01-01

    Background: The presence of stenoses that significantly impair blood flow and cause myocardial ischemia negatively affects prognosis of patients with stable coronary artery disease. Altered platelet reactivity has been associated with impaired prognosis of stable coronary artery disease. Platelets

  17. Treatment of hepatic neoplasm through extrahepatic collaterals

    Energy Technology Data Exchange (ETDEWEB)

    Soo, C.S.; Chuang, V.P.; Wallace, S.; Charnsangavej, C.; Carrasco, H.

    1983-04-01

    Twenty-nine patients with hepatic artery occlusion were treated with additional hepatic infusion or embolization through extrahepatic collaterals. Seventeen courses of hepatic infusion were performed in 13 patients through the inferior pancreaticoduodenal artery, left gastric artery, or right gastric artery. Twenty-five hepatic embolization procedures were performed in 16 patients through the right and left phrenic arteries, left and right gastric arteries, pancreaticoduodenal artery, gastroduodenal artery, or omentoepiploic artery. In one patient gastric ulcers developed following left gastric artery infusion. No complication related to the embolization procedure was observed in the embolization group. The extrahepatic collaterals are important alternative routes for continuous transcatheter management of hepatic neoplasms following hepatic artery occlusion.

  18. Treatment of hepatic neoplasm through extrahepatic collaterals

    International Nuclear Information System (INIS)

    Soo, C.S.; Chuang, V.P.; Wallace, S.; Charnsangavej, C.; Carrasco, H.

    1983-01-01

    Twenty-nine patients with hepatic artery occlusion were treated with additional hepatic infusion or embolization through extrahepatic collaterals. Seventeen courses of hepatic infusion were performed in 13 patients through the inferior pancreaticoduodenal artery, left gastric artery, or right gastric artery. Twenty-five hepatic embolization procedures were performed in 16 patients through the right and left phrenic arteries, left and right gastric arteries, pancreaticoduodenal artery, gastroduodenal artery, or omentoepiploic artery. In one patient gastric ulcers developed following left gastric artery infusion. No complication related to the embolization procedure was observed in the embolization group. The extrahepatic collaterals are important alternative routes for continuous transcatheter management of hepatic neoplasms following hepatic artery occlusion

  19. Clinical effects of transcatheter hepatic arterial embolization with holmium-166 poly(l-lactic acid) microspheres in healthy pigs

    Energy Technology Data Exchange (ETDEWEB)

    Vente, M.A.D.; Nijsen, J.F.W.; Wit, T.C. de; Schip, A.D. van het [University Medical Center Utrecht, Department of Nuclear Medicine, P.O. Box 85500, Utrecht (Netherlands); Seppenwoolde, J.H.; Seevinck, P.R. [University Medical Center Utrecht, Image Sciences Institute, Utrecht (Netherlands); Krijger, G.C. [Delft University of Technology, Department of Radiation, Radionuclides and Reactors, Faculty of Applied Sciences, Delft (Netherlands); Huisman, A. [University Medical Center Utrecht, Department of Clinical Chemistry and Haematology, Utrecht (Netherlands); Zonnenberg, B.A. [University Medical Center Utrecht, Department of Internal Medicine, Utrecht (Netherlands); Ingh, T.S.G.A.M. van den [TCCI Consultancy B.V., P.O. Box 85032, Utrecht (Netherlands)

    2008-07-15

    The aim of this study is to evaluate the toxicity of holmium-166 poly(l-lactic acid) microspheres administered into the hepatic artery in pigs. Healthy pigs (20-30 kg) were injected into the hepatic artery with holmium-165-loaded microspheres ({sup 165}HoMS; n = 5) or with holmium-166-loaded microspheres ({sup 166}HoMS; n = 13). The microspheres' biodistribution was assessed by single-photon emission computed tomography and/or MRI. The animals were monitored clinically, biochemically, and ({sup 166}HoMS group only) hematologically over a period of 1 month ({sup 165}HoMS group) or over 1 or 2 months ({sup 166}HoMS group). Finally, a pathological examination was undertaken. After microsphere administration, some animals exhibited a slightly diminished level of consciousness and a dip in appetite, both of which were transient. Four lethal adverse events occurred in the {sup 166}HoMS group due either to incorrect administration or comorbidity: inadvertent delivery of microspheres into the gastric wall (n = 2), preexisting gastric ulceration (n = 1), and endocarditis (n = 1). AST levels were transitorily elevated post-{sup 166}HoMS administration. In the other blood parameters, no abnormalities were observed. Nuclear scans were acquired from all animals from the {sup 166}HoMS group, and MRI scans were performed if available. In pigs from the {sup 166}HoMS group, atrophy of one or more liver lobes was frequently observed. The actual radioactivity distribution was assessed through ex vivo {sup 166m}Ho measurements. It can be concluded that the toxicity profile of HoMS is low. In pigs, hepatic arterial embolization with {sup 166}HoMS in amounts corresponding with liver-absorbed doses of over 100 Gy, if correctly administered, is not associated with clinically relevant side effects. This result offers a good perspective for upcoming patient trials. (orig.)

  20. Superselective intra-arterial hepatic injection of indocyanine green (ICG) for fluorescence image-guided segmental positive staining: experimental proof of the concept.

    Science.gov (United States)

    Diana, Michele; Liu, Yu-Yin; Pop, Raoul; Kong, Seong-Ho; Legnèr, Andras; Beaujeux, Remy; Pessaux, Patrick; Soler, Luc; Mutter, Didier; Dallemagne, Bernard; Marescaux, Jacques

    2017-03-01

    Intraoperative liver segmentation can be obtained by means of percutaneous intra-portal injection of a fluorophore and illumination with a near-infrared light source. However, the percutaneous approach is challenging in the minimally invasive setting. We aimed to evaluate the feasibility of fluorescence liver segmentation by superselective intra-hepatic arterial injection of indocyanine green (ICG). Eight pigs (mean weight: 26.01 ± 5.21 kg) were involved. Procedures were performed in a hybrid experimental operative suite equipped with the Artis Zeego ® , multiaxis robotic angiography system. A pneumoperitoneum was established and four laparoscopic ports were introduced. The celiac trunk was catheterized, and a microcatheter was advanced into different segmental hepatic artery branches. A near-infrared laparoscope (D-Light P, Karl Storz) was used to detect the fluorescent signal. To assess the correspondence between arterial-based fluorescence demarcation and liver volume, metallic markers were placed along the fluorescent border, followed by a 3D CT-scanning, after injecting intra-arterial radiological contrast (n = 3). To assess the correspondence between arterial and portal supplies, percutaneous intra-portal angiography and intra-arterial angiography were performed simultaneously (n = 1). Bright fluorescence signal enhancing the demarcation of target segments was obtained from 0.1 mg/mL, in matter of seconds. Correspondence between the volume of hepatic segments and arterial territories was confirmed by CT angiography. Higher background fluorescence noise was found after positive staining by intra-portal ICG injection, due to parenchymal accumulation and porto-systemic shunting. Intra-hepatic arterial ICG injection, rapidly highlights hepatic target segment borders, with a better signal-to-background ratio as compared to portal vein injection, in the experimental setting.

  1. Intervention of raltitrexed combined with epirubicin in hepatic arterial infusion and embolization in treatment of primary liver cancer

    Directory of Open Access Journals (Sweden)

    WANG Baoxin

    2015-05-01

    Full Text Available ObjectiveTo evaluate the therapeutic effect of intervention of raltitrexed combined with epirubicin in hepatic arterial infusion and embolization in the treatment of advanced primary liver cancer. MethodsA total of 80 patients with advanced primary liver cancer who were admitted to the Central Hospital of China National Petroleum Corporation from January 2011 to May 2013 and not suitable for surgical treatment were selected and randomly divided into study group (n=40 and control group (n=40. The study group was treated with intervention of raltitrexed combined with epirubicin in hepatic arterial infusion and embolization, while the control group was treated with intervention of fluorouracil (5-FU combined with epirubicin in hepatic arterial infusion and embolization. The treatment was given once every four weeks for a total of three to six circles. The response rate (RR, disease control rate (DCR, median time to progression, survival rate, and the decreases in alpha fetoprotein (AFP, carcinoembryonic antigen (CEA, transaminase, and bilirubin of the two groups were observed. Comparison of categorical data between the two groups was made by chi-square test, and comparison of continuous data was made by t test. ResultsThe RRs of the study group and control group were 52.5% and 22.5%, respectively, and the difference was significant (χ2=7.680, P=0.006; the DCRs of the study group and control group were 87.5% and 60.0%, respectively, and the difference was significant (χ2=7.813, P=0.005; the median time to progression of the study group and control group was 12.2 and 8.0 months, respectively, and the difference was significant (t=5.118, P=0.00; the 1- and 2-year survival rates of the study group were 85.0% and 60.0%, respectively, with the control group being 65.0% and 37.5%, and the difference was significant (χ2=4.267, P=0.039; χ2=4.053, P=0.044. One month after chemoembolization, the number of patients whose AFP, transaminase, and bilirubin

  2. Impaired flow-induced arterial remodeling in DOCA-salt hypertensive rats

    DEFF Research Database (Denmark)

    Lemkens, Pieter; Nelissen, Jelly; Meens, Merlijn J P M T

    2012-01-01

    Arteries from young healthy animals respond to chronic changes in blood flow and blood pressure by structural remodeling. We tested whether the ability to respond to decreased (-90%) or increased (+100%) blood flow is impaired during the development of deoxycorticosterone acetate (DOCA)-salt hype...

  3. Abnormal arterial flows by a distributed model of the fetal circulation

    NARCIS (Netherlands)

    van den Wijngaard, Jeroen P. H. M.; Westerhof, Berend E.; Faber, Dirk J.; Ramsay, Margaret M.; Westerhof, Nico; van Gemert, Martin J. C.

    2006-01-01

    Modeling the propagation of blood pressure and flow along the fetoplacental arterial tree may improve interpretation of abnormal flow velocity waveforms in fetuses. The current models, however, either do not include a wide range of gestational ages or do not account for variation in anatomical,

  4. Fractional Flow Reserve Assessment of a Coronary Artery Fistula

    Directory of Open Access Journals (Sweden)

    Joseph Petit

    2015-01-01

    Full Text Available A 63 y/o male with a past medical history of hypertension, chronic obstructive pulmonary disease, and obesity was admitted to an outside hospital for an abdominal incisional hernia repair and cholecystectomy. Post-operatively he developed shortness of breath (SOB and multiple runs of paroxysmal atrial fibrillation. A CT scan was negative for pulmonary embolism, but showed a left anterior descending (LAD coronary artery to main pulmonary artery (MPA fistula. He was transferred to our facility for further management.

  5. A clinical study concerning hepatic arterial dominant phase and arrival time of contrast media on helical dynamic CT

    International Nuclear Information System (INIS)

    Matsubara, Susumu; Uchida, Chiharu; Sato, Sei; Ishida, Junichi; Masuya, Ryozo; Makiguchi, Mako; Kanamori, Isao

    2001-01-01

    Hepatic arterial dominant phase in helical dynamic CT was optimized by measuring the arrival time of contrast media (ATCM) with time-density curve (TDC). Subjects were 1005 patients (577 males and 428 females) and 98 nodules diagnosed as advanced hepatocellular carcinoma (HCC). The CT was done with Toshiba 4MHU X-vision SP, ultrasonography with Toshiba SSH-160A and automatic infusion of the contrast medium, iopamidol or iohexol, with Nemotokyorindo Autoenhance A-50. ATCM was found correlated with pulse rate and with arterial diameter, and significantly different between the sex. Elevation slope of TDC was suggested to be made constant by a defined infusion time of the dose corrected by body weight. Fluctuation of TDC among patients , when normalized by ATCM, was found smaller and the TDC was suggested to be useful for better imaging of HCC of less than 10 mm diameter. (K.H.)

  6. Oleum of brucea javanica-lipiodol used in hepatic arterial embolization to treat hepatocellular carcinoma: a effect analysis

    International Nuclear Information System (INIS)

    Li Wanjun; Deng Li; Ai Lixin; Li Jiaping

    2005-01-01

    Objective: To investigate the effect of the Oleum of Brucea javanica lipiodol compound (BJLC), a anticancerous agent of traditional Chinese medicine, in the treatment of hepatocellular carcinoma (HCC) through transhepatic arterial embolization (TAE). Methods: BJLC was made by the mixed oleum of Brucea javanica and lipiodol was injected through hepatic artery by catheter to treat 56 patients with HCC. Results: After treatment, the tumors were shrunk 33.8% averagely. 1,2,3 year survival rates were 87.5%, 48.2% and 30.4% respectively. No marrow depression caused by the treatment were found. Conclusion: BJLC has a definite effect in treatment of HCC by TAE. As a oily anticancerous agent of traditional Chinese medicine, its conspicuous characteristic include low toxicity, embolizability and remainability in tumor tissue. so, it has a great superiority to become a satisfactory embolic agent for the treatment of HCC. (authors)

  7. Additional value of B-flow imaging in arterial wall calcifications.

    Science.gov (United States)

    D'Abate, Fabrizio; de Bruin, Jorg L

    2018-02-01

    The accuracy of color Doppler ultrasonography (CDU) is hampered by the presence of arterial wall calcifications. B-flow imaging may overcome these limitations. We present a case of a severely calcified stenosis of the right common femoral artery (CFA) diagnosed with the aid of B-flow imaging. Both the CT angiography scan and CDU were limited by the presence of diffuse dense arterial calcifications. B-flow imaging showed a >75% stenosis of the CFA. B-flow imaging appears to improve the accuracy of CDU in the presence of calcified stenosis of the CFA. It is of clinical relevance to improve the duplex sonographic accuracy, ideally reducing the need for other imaging modalities prior to surgery. © 2017 Wiley Periodicals, Inc. J Clin Ultrasound 46:136-139, 2018. © 2017 Wiley Periodicals, Inc.

  8. The comparative study between multi-slice spiral CT angiography and color flow ultrasonography in hepatic and splenic trauma

    International Nuclear Information System (INIS)

    Yan Youxia; Zhang Jin'e; Chen Xiaocong; Cai Shufang

    2007-01-01

    Objective: To investigate the clinical value of multi-slice spiral CT angiography and color flow ultra- sonography in hepatic and splenic trauma. Methods Thirty-six cases of hepatic and splenic trauma were collected, the MSCT were analyzed and compared with that of color flow ultrasonography. Results: Seventeen cases were Hepatic trauma including nine cases of hepatic contusion, six cases of sub-envelope hematoma, two cases of both sub-envelope hematoma and hepatic contusion. Nineteen cases were splenic trauma including nine cases of splenic contusion, ten cases of sub-envelope hematoma. Conclusion: Multi-slice spiral CT angiography show hepatic and splenic trauma clearer than that of color flow ultrasonography, and can provide reliable basis for clinic diagnosis and therapy. (authors)

  9. Comparative study of portal hemodynamics and regional hepatic blood flow before and after hepatic resection by 133Xe-scintiphotosplenoportography

    International Nuclear Information System (INIS)

    Yasuda, Tadashi; Sasaki, Yo; Imaoka, Shingi; Shibata, Takashi; Wada, Hisashi; Nagano, Hiroaki; Iwanaga, Takeshi; Nakano, Shunichi; Hasegawa, Yoshihisa.

    1990-01-01

    Changes in the portal circulatory pattern and regional hepatic blood flow (rHBF) after surgical liver resection were studied by 133 Xe-scintiphotosplenoportography (SSP). The visual patterns of pre- and postoperative portal circulation were compared. Different patterns were observed after the operation in five of 27 patients (porto-systemic shunt formation 3, progression 1, regression 1). The patients with porto-systemic shunt showed postopertive complications (massive ascites, jaundice, cardiopulmonary failure) more frequently than those without it. The ratio of rHBF increase (post-/pre-operative rHBF) was 1.36±0.63 on average. The ratio was higher in patients with good liver function or without liver cirrhosis. The ratio also correlated with the weight of the liver resected. But operation time, blood loss or whether hepatic blood supply was clamped off during the operation did not affect the ratio. Resection in the right lobe, however, caused a greater rHBF increase in the residual liver than the same degree of resection in the left lobe. SSP could be a useful method for investigating the effect of hepatic resection on portal hemodynamics and it is suggested that existence of portosystemic shunt influences the postoperative course. (author)

  10. Radionuclide and dopplergraphic assessment of portal hepatic blood flow in opisthorchiasis

    International Nuclear Information System (INIS)

    Borodulin, V.G.; Ermolitskij, N.M.; Zavadovskaya, V.D.; Prosekina, N.M.; Borodulin, Yu.V.

    1996-01-01

    Dynamic studies of the portal blood flow were carried out in 88 patients using colloid radionuclide gold-198 and Tc-99m-phytate and in 84 patients by dopplerography. Radionuclide studies showed that both radiopharmaceutical adequately reflected the portal blood flow in the liver. Portal blood flow values obtained by the duplex echographic method were 0.7 times lower than these estimated by radionuclide indirect angiography. The authors come to a conclusions that the share of the liver in colloid capture should be taken into consideration for the correct estimation of the level of portal hepatic hemodynamics. Portal hepatic blood flow was found markedly reduced in patients with chronic opisthorchiasis in comparison with normal controls, this difference being more expressed in male patients [ru

  11. Diagnostic accuracy of color Doppler flow imaging and Duplex US in peripheral arterial disease

    International Nuclear Information System (INIS)

    Karmel, M.I.; Polak, J.F.; Whittemore, A.D.; Mannick, J.A.; Donaldson, M.C.; O'Leary, D.H.

    1988-01-01

    Color Doppler flow imaging (5 MHz) and Duplex US were used in a prospective examination of 154 arterial segments in the lower extremities of 11 symptomatic patients. Each extremity was divided into seven arterial segments (common femoral, profunda femoral, proximal, middle, and distal superficial femoral, and proximal and distal popliteal arteries). Arterial maps were drawn for each patient and compared with the arteriograms. Seventeen significant stenoses and 18 complete occlusions were predicted and confirmed by means of arteriography. Four significant stenoses and four occlusions were predicted and not confirmed. One hundred nine normal arterial segments were correctly predicted. No significant stenoses or occlusions were missed. Prospective identification of the severity and location of disease can help to optimize both the angiographic approach and hospital services utilization

  12. Embolisation of the Gastroduodenal Artery is Not Necessary in the Presence of Reversed Flow Before Yttrium-90 Radioembolisation

    Energy Technology Data Exchange (ETDEWEB)

    Daghir, Ahmed A., E-mail: ahmeddaghir@doctors.net.uk [Imperial College Healthcare NHS Trust, Department of Radiology (United Kingdom); Gungor, Hatice [Imperial College Healthcare NHS Trust, Department of Oncology (United Kingdom); Haydar, Ali A. [Barts and the London NHS Trust, Department of Radiology (United Kingdom); Wasan, Harpreet S. [Imperial College Healthcare NHS Trust, Department of Oncology (United Kingdom); Tait, Nicholas P. [Imperial College Healthcare NHS Trust, Department of Radiology (United Kingdom)

    2012-08-15

    Introduction: The gastroduodenal artery (GDA) is usually embolised to avoid nontarget dispersal before yttrium-90 (Y{sup 90}) radioembolisation to treat liver metastases. In a minority of patients, there is retrograde flow in the GDA. The purpose of this study was to determine if there is any increased risk from maintaining a patent GDA in patients with reversed flow. Materials and Methods: A retrospective review was performed of all patients undergoing Y{sup 90} radioembolisation at our institution. The incidence of toxicities arising from nontarget radioembolisation by way of the GDA (gastric/duodenal ulceration, gastric/duodenal bleeding, and pancreatitis) and death occurring within 2 months of treatment were compared between the reversed and the antegrade GDA groups. Results: Ninety-two patients underwent preliminary angiography. Reversed GDA flow was found on angiography in 14.1% of cases; the GDA was not embolised in these patients. The GDA was coiled in 55.7% of patients with antegrade GDA flow to prevent inadvertent dispersal of radioembolic material. There was no increased toxicity related to nontarget dispersal by way of the GDA, or increased early mortality, in patients with reversed GDA flow (P > 0.05). Conclusion: In patients with reversed GDA flow, maintenance of a patent GDA before administration of Y{sup 90} radioembolisation does not increase the risk of toxicity from nontarget dispersal. Therapeutic injection, with careful monitoring to identify early vascular stasis, may be safely performed beyond the origin of the patent GDA. A patent GDA with reversed flow provides forward drive for infused particles and may allow alternative access to the hepatic circulation.

  13. Enhancement of Arterial Pressure Pulsatility by Controlling Continuous-Flow Left Ventricular Assist Device Flow Rate in Mock Circulatory System.

    Science.gov (United States)

    Bozkurt, Selim; van de Vosse, Frans N; Rutten, Marcel C M

    Continuous-flow left ventricular assist devices (CF-LVADs) generally operate at a constant speed, which reduces pulsatility in the arteries and may lead to complications such as functional changes in the vascular system, gastrointestinal bleeding, or both. The purpose of this study is to increase the arterial pulse pressure and pulsatility by controlling the CF-LVAD flow rate. A MicroMed DeBakey pump was used as the CF-LVAD. A model simulating the flow rate through the aortic valve was used as a reference model to drive the pump. A mock circulation containing two synchronized servomotor-operated piston pumps acting as left and right ventricles was used as a circulatory system. Proportional-integral control was used as the control method. First, the CF-LVAD was operated at a constant speed. With pulsatile-speed CF-LVAD assistance, the pump was driven such that the same mean pump output was generated. Continuous and pulsatile-speed CF-LVAD assistance provided the same mean arterial pressure and flow rate, while the index of pulsatility increased significantly for both arterial pressure and pump flow rate signals under pulsatile speed pump support. This study shows the possibility of improving the pulsatility of CF-LVAD support by regulating pump speed over a cardiac cycle without reducing the overall level of support.

  14. Reversal of flow in the inferior vena cava and hepatic veins on dynamic CT

    International Nuclear Information System (INIS)

    Lelij, H. van der; Mallens, W.M.C.

    1988-01-01

    A tricuspid insufficiency may not be clinically evident and may remain unknown to the clinician. The phenomenon of a reversal of inferior vena caval blood flow and hepatic veins is known to occur in tricuspid regurgitation from right ventricular angiography and duplex scanning. Demonstration of such a reversal flow on a dynamic CT scan, as in our case, has, to our knowledge, not as yet been reported

  15. Renal hemodynamics: the influence of the renal artery ostium flow diverter

    Science.gov (United States)

    Rossmann, Jenn Stroud; Albert, Scott; Balaban, Robert

    2013-11-01

    The recently identified renal artery ostium flow diverter may preferentially direct blood flow to the renal arteries, and may also influence flow patterns and recirculation known to be involved in atherogenesis. Three-dimensional computational fluid dynamics (CFD) simulations of steady and pulsatile blood flow are performed to investigate the influence of diverter size and position, and vascular geometry, on the flow patterns and fluid mechanical forces in the neighborhood of the diverter. CFD results show that the flow diverter does affect the blood distribution: depending on the diverter's position, the flow to the renal arteries may be increased or reduced. The results of simulations also show the diverter's effect on the Wall Shear Stress (WSS) distribution, and suggest that the diverter contributes to an atherogenic environment in the abdominal aorta, while being atheroprotective in the renal arteries themselves. These results support previous clinical findings, and suggest directions for further clinical study. The results of this work have direct implications in understanding the physiological significance of the diverter, and its potential role in the pathophysiological development of atherosclerosis.

  16. Collateral Flow and White Matter Disease in Patients with Internal Carotid Artery Occlusion.

    Science.gov (United States)

    Ishikawa, Mami; Sugawara, Hitoshi; Nagai, Mutsumi; Kusaka, Gen; Tanaka, Yuichi; Naritaka, Heiji

    2017-01-01

    When an internal carotid artery (ICA) occludes, a patient may develop cerebral infarction (CI). We investigated whether CI caused by ICA occlusion (ICAO) is associated with collateral flow through the anterior and posterior communicating arteries (ACoA and PCoA). In 100 patients with ICAO, we investigated CI and white matter disease by performing an MRI and the anatomy of the ACoA and PCoA were investigated by performing magnetic resonance angiography. All patients were divided into the symptomatic CI group or the no-CI group. The collateral flow pathway was estimated by the anterior cerebral artery (ACA)-PCoA score and the collateral flow volume after ICAO was estimated by the middle cerebral artery (MCA) flow score, based on how well the MCA was visualized. Of 100 patients with ICAO, the symptomatic CI group included 36 patients. ACA-PCoA score and white matter disease grades were significantly higher in the CI group (indicating poor collateral flow). More than 80% of patients with an ACA-PCoA score of 4 (poor collateral) experienced symptomatic CI. Thirty-one symptomatic CI patients (86%) had an MCA flow score of 1 or 2 (decreased MCA flow). The ACA-PCoA score and white matter disease grade may suggest an increased risk of CI following ICAO. © 2016 S. Karger AG, Basel.

  17. Accuracy and Precision of a Plane Wave Vector Flow Imaging Method in the Healthy Carotid Artery

    DEFF Research Database (Denmark)

    Jensen, Jonas; Villagómez Hoyos, Carlos Armando; Traberg, Marie Sand

    2018-01-01

    The objective of the study described here was to investigate the accuracy and precision of a plane wave 2-D vector flow imaging (VFI) method in laminar and complex blood flow conditions in the healthy carotid artery. The approach was to study (i) the accuracy for complex flow by comparing...... of laminar flow in vivo. The precision in vivo was calculated as the mean standard deviation (SD) of estimates aligned to the heart cycle and was highest in the center of the common carotid artery (SD = 3.6% for velocity magnitudes and 4.5° for angles) and lowest in the external branch and for vortices (SD...... the velocity field from a computational fluid dynamics (CFD) simulation to VFI estimates obtained from the scan of an anthropomorphic flow phantom and from an in vivo scan; (ii) the accuracy for laminar unidirectional flow in vivo by comparing peak systolic velocities from VFI with magnetic resonance...

  18. Resting quantitative cerebral blood flow in schizophrenia measured by pulsed arterial spin labeling perfusion MRI

    OpenAIRE

    Pinkham, Amy; Loughead, James; Ruparel, Kosha; Wu, Wen-Chau; Overton, Eve; Gur, Raquel; Gur, Ruben

    2011-01-01

    Arterial spin labeling imaging (ASL) perfusion MRI is a relatively novel technique that can allow for quantitative measurement of cerebral blood flow (CBF) by using magnetically labeled arterial blood water as an endogenous tracer. Available data on resting CBF in schizophrenia primarily comes from invasive and expensive nuclear medicine techniques that are often limited to small samples and yield mixed results. The noninvasive nature of ASL offers promise for larger-scale studies. The utilit...

  19. Evaluation of pulmonary artery flow in acute massive pulmonary thromboembolism with MRI

    International Nuclear Information System (INIS)

    Li Yongzhong; Li Kuncheng; Zhao Xigang; Zhao Hong

    2004-01-01

    Objective: To probe into the value of MR imaging in evaluating the pulmonary artery hemodynamics and pulmonary artery pressure in acute massive pulmonary embolism. Methods: MR studies were performed in 21 patients with acute massive pulmonary embolism (diagnosed by contrast enhanced MR pulmonary angiography) and 20 healthy volunteers. The pulmonary artery hemodynamic parameters, such as the diameters of main and right pulmonary artery, peak velocity, average velocity, flow volume, flow patterns, and ejection acceleration time in main pulmonary artery were measured. The findings in patients and volunteers were compared. The hemodynamic parameters in patients were correlated with mean pulmonary artery pressure acquired with right heart catheterization. Results: The diameters of main pulmonary artery (2.93 vs 2.52 cm) and right pulmonary artery (2.49 vs 1.92 cm) in patients and volunteers showed significant differences (t=3.55, P<0.01 and t=4.19, P<0.01, respectively); Peak velocity (85.29 vs 100.63 cm/s), average velocity (11.00 vs 17.12 cm/s), flow volume (89.15 vs 98.96 ml/s), and ejection acceleration time (105.09 vs 163.85 ms) in main pulmonary artery were significantly different between patients and volunteers (t values were 2.89, 6.37, 2.21, and 9.46, respectively; P values were 0.01, <0.01, 0.03, and <0.01, respectively). The peak velocity-time curve of main pulmonary artery acquired with velocity encoded cine of MR in patients demonstrated earlier and lower peak velocity as well as abnormal retrograde flow. In addition, linear correlations were seen between the mean pulmonary pressure and the diameter of main pulmonary artery (r=0.62, P=0.001), diameter of right pulmonary artery (r=0.63, P=0.001), and ejection acceleration time (r=-0.55, P=0.005). Conclusion: MR imaging is a promising technique not only for the detection of pulmonary thromboemboli but also for the evaluation of hemodynamic parameters in pulmonary hypertension. (author)

  20. Numerical investigation of MHD flow of blood and heat transfer in a stenosed arterial segment

    Energy Technology Data Exchange (ETDEWEB)

    Majee, Sreeparna; Shit, G.C., E-mail: gcs@math.jdvu.ac.in

    2017-02-15

    A numerical investigation of unsteady flow of blood and heat transfer has been performed with an aim to provide better understanding of blood flow through arteries under stenotic condition. The blood is treated as Newtonian fluid and the arterial wall is considered to be rigid having deposition of plaque in its lumen. The heat transfer characteristic has been analyzed by taking into consideration of the dissipation of energy due to applied magnetic field and the viscosity of blood. The vorticity-stream function formulation has been adopted to solve the problem using implicit finite difference method by developing well known Peaceman–Rachford Alternating Direction Implicit (ADI) scheme. The quantitative profile analysis of velocity, temperature and wall shear stress as well as Nusselt number is carried out over the entire arterial segment. The streamline and temperature contours have been plotted to understand the flow pattern in the diseased artery, which alters significantly in the downstream of the stenosis in the presence of magnetic field. Both the wall shear stress and Nusselt number increases with increasing magnetic field strength. However, wall shear stress decreases and Nusselt number enhances with Reynolds number. The results show that with an increase in the magnetic field strength upto 8 T, does not causes any damage to the arterial wall, but the study is significant for assessing temperature rise during hyperthermic treatment. - Highlights: • Fully numerical simulation is carried out for MHD blood flow in stenosed artery. • Dissipation of energy due to both magnetic field and blood viscosity is considered. • Strong Vortices are observed at the downstream of the stenosis in the arterial wall. • Flow reversal of blood is reduced by applying sufficient magnetic field strength. • Isothermal lines are strongly distorted in the presence of magnetic field strength.

  1. Arterial Transit Time-corrected Renal Blood Flow Measurement with Pulsed Continuous Arterial Spin Labeling MR Imaging.

    Science.gov (United States)

    Shimizu, Kazuhiro; Kosaka, Nobuyuki; Fujiwara, Yasuhiro; Matsuda, Tsuyoshi; Yamamoto, Tatsuya; Tsuchida, Tatsuro; Tsuchiyama, Katsuki; Oyama, Nobuyuki; Kimura, Hirohiko

    2017-01-10

    The importance of arterial transit time (ATT) correction for arterial spin labeling MRI has been well debated in neuroimaging, but it has not been well evaluated in renal imaging. The purpose of this study was to evaluate the feasibility of pulsed continuous arterial spin labeling (pcASL) MRI with multiple post-labeling delay (PLD) acquisition for measuring ATT-corrected renal blood flow (ATC-RBF). A total of 14 volunteers were categorized into younger (n = 8; mean age, 27.0 years) and older groups (n = 6; 64.8 years). Images of pcASL were obtained at three different PLDs (0.5, 1.0, and 1.5 s), and ATC-RBF and ATT were calculated using a single-compartment model. To validate ATC-RBF, a comparative study of effective renal plasma flow (ERPF) measured by 99m Tc-MAG3 scintigraphy was performed. ATC-RBF was corrected by kidney volume (ATC-cRBF) for comparison with ERPF. The younger group showed significantly higher ATC-RBF (157.68 ± 38.37 mL/min/100 g) and shorter ATT (961.33 ± 260.87 ms) than the older group (117.42 ± 24.03 mL/min/100 g and 1227.94 ± 226.51 ms, respectively; P renal ASL-MRI as debated in brain imaging.

  2. Imatinib mesylate induces responses in patients with liver metastases from gastrointestinal stromal tumor failing intra-arterial hepatic chemotherapy

    Directory of Open Access Journals (Sweden)

    Fiorentini Giammaria

    2006-01-01

    Full Text Available Background: Imatinib mesylate represents a real major paradigm shift in cancer therapy, targeting the specific molecular abnormalities, crucial in the etiology of tumor. Intra-arterial hepatic chemotherapy (IAHC followed by embolization, has been considered an interesting palliative option for patients with liver metastases from gastrointestinal stromal tumor (GIST, due to the typically hypervascular pattern of the tumor. Aims: We report our experience with IAHC followed by Imatinib mesylate, in order to show the superiority of the specific molecular approach in liver metastases from GIST. Materials and Methods: Three patients (pts with pretreated massive liver metastases from GIST, received IAHC with Epirubicin 50 mg/mq, every 3 weeks for 6 cycles. At the evidence of progression, they received Imatinib mesylate. Results: We observed progressive diseases in all cases. In 1998, one patient underwent Thalidomide at 150 mg orally, every day for 4 months, with evidence of stable disease and clinical improvement. In 2001, two patients received Imatinib mesylate at 400 mg orally, every day, with evidence of partial response lasting 18+ months and 16 months. One of them had grade 3 neutropenia, with suspension of therapy for 3 weeks. Conclusion: No patient treated with IAHC, reported objective responses, but two of them obtained partial response after the assumption of Imatinib mesylate and one showed temporary stabilization with thalidomide. Imatinib mesylate represents a new opportunity in GIST therapy, targeting the specific molecular alteration. It seems to be superior to conventional intra arterial hepatic chemotherapy.

  3. Twenty-four-hour exposure to altered blood flow modifies endothelial Ca2+-activated K+ channels in rat mesenteric arteries

    DEFF Research Database (Denmark)

    Hilgers, Rob H P; Janssen, Ger M J; Fazzi, Gregorio E

    2010-01-01

    We tested the hypothesis that changes in arterial blood flow modify the function of endothelial Ca2+-activated K+ channels [calcium-activated K+ channel (K(Ca)), small-conductance calcium-activated K+ channel (SK3), and intermediate calcium-activated K+ channel (IK1)] before arterial structural...... remodeling. In rats, mesenteric arteries were exposed to increased [+90%, high flow (HF)] or reduced blood flow [-90%, low flow (LF)] and analyzed 24 h later. There were no detectable changes in arterial structure or in expression level of endothelial nitric-oxide synthase, SK3, or IK1. Arterial relaxing...... arteries, the balance between the NO/prostanoid versus EDHF response was unaltered. However, the contribution of IK1 to the EDHF response was enhanced, as indicated by a larger effect of TRAM-34 and a larger residual NS309-induced relaxation in the presence of UCL 1684. Reduction of blood flow selectively...

  4. Unsteady Blood Flow with Nanoparticles Through Stenosed Arteries in the Presence of Periodic Body Acceleration

    Science.gov (United States)

    Fatin Jamil, Dzuliana; Roslan, Rozaini; Abdulhameed, Mohammed; Che-Him, Norziha; Sufahani, Suliadi; Mohamad, Mahathir; Ghazali Kamardan, Muhamad

    2018-04-01

    The effects of nanoparticles such as Fe 3O4,TiO2, and Cu on blood flow inside a stenosed artery are studied. In this study, blood was modelled as non-Newtonian Bingham plastic fluid subjected to periodic body acceleration and slip velocity. The flow governing equations were solved analytically by using the perturbation method. By using the numerical approaches, the physiological parameters were analyzed, and the blood flow velocity distributions were generated graphically and discussed. From the flow results, the flow speed increases as slip velocity increases and decreases as the values of yield stress increases.

  5. A 2D nonlinear multiring model for blood flow in large elastic arteries

    Science.gov (United States)

    Ghigo, Arthur R.; Fullana, Jose-Maria; Lagrée, Pierre-Yves

    2017-12-01

    In this paper, we propose a two-dimensional nonlinear ;multiring; model to compute blood flow in axisymmetric elastic arteries. This model is designed to overcome the numerical difficulties of three-dimensional fluid-structure interaction simulations of blood flow without using the over-simplifications necessary to obtain one-dimensional blood flow models. This multiring model is derived by integrating over concentric rings of fluid the simplified long-wave Navier-Stokes equations coupled to an elastic model of the arterial wall. The resulting system of balance laws provides a unified framework in which both the motion of the fluid and the displacement of the wall are dealt with simultaneously. The mathematical structure of the multiring model allows us to use a finite volume method that guarantees the conservation of mass and the positivity of the numerical solution and can deal with nonlinear flows and large deformations of the arterial wall. We show that the finite volume numerical solution of the multiring model provides at a reasonable computational cost an asymptotically valid description of blood flow velocity profiles and other averaged quantities (wall shear stress, flow rate, ...) in large elastic and quasi-rigid arteries. In particular, we validate the multiring model against well-known solutions such as the Womersley or the Poiseuille solutions as well as against steady boundary layer solutions in quasi-rigid constricted and expanded tubes.

  6. Spiral blood flows in an idealized 180-degree curved artery model

    Science.gov (United States)

    Bulusu, Kartik V.; Kulkarni, Varun; Plesniak, Michael W.

    2017-11-01

    Understanding of cardiovascular flows has been greatly advanced by the Magnetic Resonance Velocimetry (MRV) technique and its potential for three-dimensional velocity encoding in regions of anatomic interest. The MRV experiments were performed on a 180-degree curved artery model using a Newtonian blood analog fluid at the Richard M. Lucas Center at Stanford University employing a 3 Tesla General Electric (Discovery 750 MRI system) whole body scanner with an eight-channel cardiac coil. Analysis in two regions of the model-artery was performed for flow with Womersley number=4.2. In the entrance region (or straight-inlet pipe) the unsteady pressure drop per unit length, in-plane vorticity and wall shear stress for the pulsatile, carotid artery-based flow rate waveform were calculated. Along the 180-degree curved pipe (curvature ratio =1/7) the near-wall vorticity and the stretching of the particle paths in the vorticity field are visualized. The resultant flow behavior in the idealized curved artery model is associated with parameters such as Dean number and Womersley number. Additionally, using length scales corresponding to the axial and secondary flow we attempt to understand the mechanisms leading to the formation of various structures observed during the pulsatile flow cycle. Supported by GW Center for Biomimetics and Bioinspired Engineering (COBRE), MRV measurements in collaboration with Prof. John K. Eaton and, Dr. Chris Elkins at Stanford University.

  7. Enhancement of arterial pressure pulsatility by controlling continuous-flow left ventricular assist device flow rate in mock circulatory system

    NARCIS (Netherlands)

    Bozkurt, S.; van de Vosse, F.N.; Rutten, M.C.M.

    Continuous-flow left ventricular assist devices (CF-LVADs) generally operate at a constant speed, which reduces pulsatility in the arteries and may lead to complications such as functional changes in the vascular system, gastrointestinal bleeding, or both. The purpose of this study is to increase

  8. Utilizing generalized autocalibrating partial parallel acquisition (GRAPPA) to achieve high-resolution contrast-enhanced MR angiography of hepatic artery: Initial experience in orthotopic liver transplantation candidates

    International Nuclear Information System (INIS)

    Xu Pengju; Yan Fuhua; Wang Jianhua; Lin Jiang; Fan Jia

    2007-01-01

    Objective: To evaluate feasibility of using GRAPPA to acquire high-resolution 3D contrast-enhanced MR angiography (CE-MRA) of hepatic artery and value of GRAPPA for displaying vessels anatomy. Materials and methods: High-resolution CE-MRA using GRAPPA was performed in 67 orthotopic liver transplantation recipient candidates. Signal intensity (SI) and relative SI, i.e., Cv-ro (vessel-to-liver contrast) of the aorta and the hepatic common artery (HCA), were measured. The SI and the relative SI were compared and analyzed using T-test. For purpose of qualitative evaluation, the vessel visualization quality and the order of depicted hepatic artery branches were evaluated by two radiologists independently and assessed by weighted kappa analysis. The depiction of hepatic arterial anatomy and variations was evaluated, and results were correlated with the findings in surgery. Results: The mean SI values were 283.29 ± 65.07 (mean ± S.D.) for aorta and 283.16 ± 64.07 for HCA, respectively. The mean relative SI values were 0.698 ± 0.09 for aorta and 0.696 ± 0.09 for HCA, respectively. Homogeneous enhancement between aorta and HCA was confirmed by statistically insignificant differences (p-values were 0.89 for mean SI values and 0.12 for mean relative SI values, respectively). The average score for vessel visualization ranged from good to excellent for different artery segments. Overall interobserver agreement in the visualization of different artery segments was excellent (kappa value > 0.80). The distal intrahepatic segmental arteries were well delineated for majority of patients with excellent interobserver agreement. Normal hepatic arterial anatomy was correctly demonstrated in 53 patients, and arterial anomalies were accurately detected on high-resolution MRA image of all 14 patients. Conclusion: High-resolution hepatic artery MRA acquired using GRAPPA in a reproducible manner excellently depicts and delineates small vessels and can be routinely used for evaluating

  9. Relationship between vertebral artery blood flow in different head positions and vertigo.

    Science.gov (United States)

    Araz Server, Ela; Edizer, Deniz Tuna; Yiğit, Özgür; Yasak, Ahmet Görkem; Erdim, Çağrı

    2018-01-01

    To identify the vertebral artery blood flow in different head positions in patients with positional vertigo with no specific diagnosis. Patients with history of vestibular symptoms associated with changes in head position were enrolled into the study. Healthy volunteers were evaluated as control group. Doppler ultrasonography examination of the cervical segment of the vertebral arteries was performed under three different head positions: (i) supine position, (ii) head hyperextended and rotated to the right side and (iii) head hyperextended and rotated to the left side. In the study group, right and left vertebral artery blood flow was significantly lower in the ipsilateral hyperextended position compared to standard supine position (respectively p = .014; p = .001), but did not differ significantly when compared between the standard supine and contralateral hyperextended positions (respectively = .959; p = .669). In the control group, left and right vertebral artery blood flow did not differ significantly when the head was hyperextended to the right or left sides compared to standard supine position (p > .05). Our data demonstrated that the etiology of vestibular complaints in patients with undiagnosed positional vertigo might be related to impairment in vertebral artery blood flow according to head positions.

  10. Carotid Artery Stenting in a Patient With a Continuous-Flow Left Ventricular Assist Device.

    Science.gov (United States)

    Piazza, Michele; Squizzato, Francesco; Grego, Franco; Bottio, Tommaso; Gerosa, Gino; Antonello, Michele

    2016-08-01

    To demonstrate the safety and feasibility of carotid artery stenting (CAS) in a patient with a continuous-flow left ventricular assist device (LVAD). A 54-year-old woman with a LVAD was referred for a 90% stenosis of the right internal carotid artery (ICA). The patient was offered CAS, and oral anticoagulant was not discontinued in the periprocedural period. Because of absent arterial pulses, percutaneous transfemoral access was obtained under ultrasound guidance. Particular attention was paid to cannulation of the innominate artery; a 7-F guiding catheter was advanced from the descending aorta into the innominate artery under road-mapping, avoiding maneuvers in the ascending aorta where the outflow Dacron graft of the LVAD was anastomosed. To avoid cerebral flow modifications, the Angioguard RX was used as the cerebral protection device rather than other devices such as the flow reversal or flow-clamping systems. At this point, CAS was performed in a standard fashion using the 7×30-mm Precise ProRX stent. The computed tomography angiogram at 6 months showed patency of the stented right ICA. With adequate planning, CAS appears feasible in patients with a LVAD. © The Author(s) 2016.

  11. Evaluation of the carotid artery stenosis based on minimization of mechanical energy loss of the blood flow.

    Science.gov (United States)

    Sia, Sheau Fung; Zhao, Xihai; Li, Rui; Zhang, Yu; Chong, Winston; He, Le; Chen, Yu

    2016-11-01

    Internal carotid artery stenosis requires an accurate risk assessment for the prevention of stroke. Although the internal carotid artery area stenosis ratio at the common carotid artery bifurcation can be used as one of the diagnostic methods of internal carotid artery stenosis, the accuracy of results would still depend on the measurement techniques. The purpose of this study is to propose a novel method to estimate the effect of internal carotid artery stenosis on the blood flow based on the concept of minimization of energy loss. Eight internal carotid arteries from different medical centers were diagnosed as stenosed internal carotid arteries, as plaques were found at different locations on the vessel. A computational fluid dynamics solver was developed based on an open-source code (OpenFOAM) to test the flow ratio and energy loss of those stenosed internal carotid arteries. For comparison, a healthy internal carotid artery and an idealized internal carotid artery model have also been tested and compared with stenosed internal carotid artery in terms of flow ratio and energy loss. We found that at a given common carotid artery bifurcation, there must be a certain flow distribution in the internal carotid artery and external carotid artery, for which the total energy loss at the bifurcation is at a minimum; for a given common carotid artery flow rate, an irregular shaped plaque at the bifurcation constantly resulted in a large value of minimization of energy loss. Thus, minimization of energy loss can be used as an indicator for the estimation of internal carotid artery stenosis.

  12. Improved assessment of functional severity of coronary artery stenosis by analysis of combined intracoronary pressure and flow velocity signals

    NARCIS (Netherlands)

    Nolte, F.

    2014-01-01

    Coronary artery disease (CAD) accounts for almost 2 million deaths per year within the EU. CAD is often characterized by focal narrowing of epicardial arteries, limiting coronary arterial flow and myocardial perfusion. Treatment of critical lesions by percutaneous coronary intervention (PCI) can be

  13. Estimation of brachial artery volume flow by duplex ultrasound imaging predicts dialysis access maturation.

    Science.gov (United States)

    Ko, Sae Hee; Bandyk, Dennis F; Hodgkiss-Harlow, Kelley D; Barleben, Andrew; Lane, John

    2015-06-01

    This study validated duplex ultrasound measurement of brachial artery volume flow (VF) as predictor of dialysis access flow maturation and successful hemodialysis. Duplex ultrasound was used to image upper extremity dialysis access anatomy and estimate access VF within 1 to 2 weeks of the procedure. Correlation of brachial artery VF with dialysis access conduit VF was performed using a standardized duplex testing protocol in 75 patients. The hemodynamic data were used to develop brachial artery flow velocity criteria (peak systolic velocity and end-diastolic velocity) predictive of three VF categories: low (800 mL/min). Brachial artery VF was then measured in 148 patients after a primary (n = 86) or revised (n = 62) upper extremity dialysis access procedure, and the VF category correlated with access maturation or need for revision before hemodialysis usage. Access maturation was conferred when brachial artery VF was >600 mL/min and conduit imaging indicated successful cannulation based on anatomic criteria of conduit diameter >5 mm and skin depth 800 mL/min was predicted when the brachial artery lumen diameter was >4.5 mm, peak systolic velocity was >150 cm/s, and the diastolic-to-systolic velocity ratio was >0.4. Brachial artery velocity spectra indicating VF 800 mL/min. Duplex testing to estimate brachial artery VF and assess the conduit for ease of cannulation can be performed in 5 minutes during the initial postoperative vascular clinic evaluation. Estimation of brachial artery VF using the duplex ultrasound, termed the "Fast, 5-min Dialysis Duplex Scan," facilitates patient evaluation after new or revised upper extremity dialysis access procedures. Brachial artery VF correlates with access VF measurements and has the advantage of being easier to perform and applicable for forearm and also arm dialysis access. When brachial artery velocity spectra criteria confirm a VF >800 mL/min, flow maturation and successful hemodialysis are predicted if anatomic criteria

  14. Radionuclide scanning in a study of the pulmonary blood flow with the open arterial canal

    International Nuclear Information System (INIS)

    Rizaev, M.N.; Gulyamov, D.S.; Khodzhibekov, M.Kh.; Anvarov, M.A.

    1980-01-01

    Characteristic features of the distribution of the arterial pulmonary blood flow have been studied in 32 patients with the open arterial flow by lung scanning with albumin macroaggregate and 131 I. Research was conducted using the gamma-Ochamber ''Fo Gamma LFV'' and the scanner ''Magnaskaner 500I''. Disordered distribution of the pulmonary blood flow expressed in its unilateral decrease was detected in 17 patients (52.9%). A higher frequency of pulmonary hypertension was noted in these patients versus those with a relatively normal distribution of the pulmonary blood flow. A severe course of the disease was observed in high pulmonary hypertension combined with sharp suppression of the blood flow in one of the lungs or with signs of the shift from the right to the left side

  15. Quantitative determination of pulmonary artery flow by scintiscanning in patients with mitral stenosis

    International Nuclear Information System (INIS)

    Carvalho, N.; Fujioka, T.; Dias Neto, A.; Papaleo Netto, M.

    1974-01-01

    In twenty-two patients with pure or predominant mitral stenosis, with pulmonary hypertension, the quantitative blood flow of the pulmonary artery systems through the distribution of macroaggregated radio-iodinated ( 131 I) albumin is studied, by pulmonary digital scanning. Through the relations ship between the radioactive concentration in each organ, it is possible to classify three types of images: normal, balanced and inverted. This technique is useful for quantitative analysis of pulmonary artery flow, as a test that should preced cardiac catheterization and in the follow-up of the surgical results [pt

  16. Short-term clinical implications of the accessory left hepatic artery in patients undergoing radical gastrectomy for gastric cancer.

    Directory of Open Access Journals (Sweden)

    Chang-Ming Huang

    Full Text Available BACKGROUND: To evaluate the prevalence of the accessory left hepatic artery (ALHA; defined as a vessel arising from the left gastric artery, which, together with a typical left hepatic artery, supplies blood to the left lobe of the liver and its short-term clinical implications in patients undergoing radical gastrectomy for gastric cancer. METHODS: Clinical data of 1173 patients with gastric cancer who underwent laparoscopy-assisted radical gastrectomy were retrospectively analyzed. Groups of patients with and without ALHA were compared to identify differences in intraoperative and postoperative variables and changes in liver function. RESULTS: Of the 1173 patients, 135 (11.5% had an ALHA and 1038 (88.5% did not. There were no significant between-group differences in clinicopathological and intraoperative characteristics, postoperative recovery, and morbidity and mortality rates (P>0.05 each. None of the patients had postoperative symptoms associated with impaired liver function. Glutamic oxaloacetic transaminase (GOT, glutamic pyruvic transaminase (GPT and total bilirubin (TBIL concentrations were similar preoperatively. TBIL concentrations on postoperative days 1, 3, and 7 were similar (P>0.05, while GOT and GPT activities were higher in the ALHA than in the non-ALHA group on days 1 and 7 (P<0.05, with all three markers similar in the two groups on day 14. In patients without chronic liver disease (CLD, GOT, GPT and TBIL concentrations were similar in patients with and without ALHA; whereas, in patients with CLD, GOT and GPT concentrations on days 1 and 3 and GOT on day 7 were higher in patients with than without ALHA. CONCLUSION: ALHA is a common anomaly that was found in 11.5% of patients. It can be safely severed during radical gastrectomy in patients without CLD, but should be left intact in patients with CLD to prevent liver dysfunction. If severed in the latter, the patient should be monitored and liver-protecting therapy may be

  17. INFLUENCE OF PERI-ARTERIAL HEPATIC DENERVATION ON THE GLYCEMIC RESPONSE TO EXERCISE IN RATS

    NARCIS (Netherlands)

    LINDFELDT, J; BALKAN, B; VANDIJK, G; SCHEURINK, A; AHREN, B; STEFFENS, AB

    Exercise is known to increase hepatic glucose production. Previous studies have suggested that the sympathetic nerves only marginally contribute to this process. This study examined whether increased catecholamine response or increased adrenoceptor sensitivity might have affected previous results

  18. Unsatisfactory hepatic perfusion after placement of the infusaid pump: Angiographic correlation

    International Nuclear Information System (INIS)

    Andrews, J.C.; Williams, D.M.; Cho, K.J.; Knol, J.A.; Wahl, R.L.; Ensminger, W.D.

    1988-01-01

    Complete perfusion limited to the liver is essential to the success of regional chemotherapy for hepatic malignancy. Thirty-three patients with unsatisfactory hepatic artery perfusion scintigrams after surgical placement of a pump and catheter system were evaluated with selective angiography (31 cases) or digital subtraction angiography (DSA) via the pump side port (six cases). The cause of the perfusion defect was hepatic artery thrombosis (14 cases), extrahepatic flow through collaterals (13 cases), misplaced catheter (three cases), short proper hepatic artery without adequate length for mixing (two cases), and undefined (one case). DSA findings were diagnostic in only two cases. Angiographic findings directed attempted correction in 22 of 33 cases

  19. Haemodynamic study of Flow in concentric and eccentric stenosed carotid Artery

    Directory of Open Access Journals (Sweden)

    Khader S. M. Abdul

    2018-01-01

    Full Text Available Study of flow through arteries is gaining importance in the recent times due to onset of several cardio-vascular diseases like atherosclerosis (block in artery, aneurysms (bulging of artery, hypertension etc. The application of CFD will be useful in demonstrating the underlying mechanism of flow past the diseased arteries. In the present study, initially an approximate eccentric and concentric 50% stenosed carotid model is generated in ANSYS 12.0 based on patient data obtained from ultrasound Doppler scan. Later the percentage of stenosis is increased to 60%, 70%, 80% and 90% in both the cases. A transient analysis has been performed for several pulse cycles in ANSYS FLOTRAN for various percentage cases. The results obtained from ECN and CCN cases are compared to observe the changes in flow behavior in the downstream of stenosis as compared with normal case. The formation of vortices and flow separation zone in downstream in eccentric case is higher than in concentric case. Comparison of results concludes that, with the increase in severity of stenosis, the flow changes abruptly causing an increase in velocity and WSS at throat region. The simulation results obtained agree well with clinically observed data and available literature.

  20. Early Introduction of Everolimus Immunosuppressive Regimen in Liver Transplantation with Extra-Anatomic Aortoiliac-Hepatic Arterial Graft Anastomosis

    Directory of Open Access Journals (Sweden)

    Emanuele Felli

    2014-01-01

    Full Text Available Liver transplantation is the treatment of choice for patients with acute and chronic end-stage liver disease, when no other medical treatment is possible. Despite high rates of 1- to 5-year survival, long-term adverse effects of immunosuppressant agents remain of major concern. Current research and clinical efforts are made to develop immunosuppressant agents that minimize adverse effects along with a low rate of graft rejection. Tailoring immunosuppressive therapy to individual patients by the use of proliferation signal inhibitors seems to be the best way to minimize toxicity and increase efficacy. Recently everolimus has been introduced in clinical practice; among its adverse effects an increased incidence of arterial graft thrombosis in renal transplants, vascular anastomosis leakage, impaired wound healing, and thrombotic microangiopathy have been reported. We present the case of a 54-year-old patient submitted to liver transplantation for end-stage liver disease treated by an extra-anatomic aortoiliac-hepatic arterial graft anastomosis and early postoperative introduction of everolimus for acute renal failure. Postoperative period was characterized by two abdominal collections and reactivation of cytomegalovirus infection that were treated by percutaneous drainage and antiviral therapy, respectively; the patient is well after 8-month followup with patency of the arterial conduit and no leakage.

  1. Minimal vascular flows cause strong heat sink effects in hepatic radiofrequency ablation ex vivo.

    Science.gov (United States)

    Lehmann, Kai S; Poch, Franz G M; Rieder, Christian; Schenk, Andrea; Stroux, Andrea; Frericks, Bernd B; Gemeinhardt, Ole; Holmer, Christoph; Kreis, Martin E; Ritz, Jörg P; Zurbuchen, Urte

    2016-08-01

    The present paper aims to assess the lower threshold of vascular flow rate on the heat sink effect in bipolar radiofrequency ablation (RFA) ex vivo. Glass tubes (vessels) of 3.4 mm inner diameter were introduced in parallel to bipolar RFA applicators into porcine liver ex vivo. Vessels were perfused with flow rates of 0 to 1,500 ml/min. RFA (30 W power, 15 kJ energy input) was carried out at room temperature and 37°C. Heat sink effects were assessed in RFA cross sections by the decrease in ablation radius, area and by a high-resolution sector planimetry. Flow rates of 1 ml/min already caused a significant cooling effect (P ≤ 0.001). The heat sink effect reached a maximum at 10 ml/min (18.4 mm/s) and remained stable for flow rates up to 1,500 ml/min. Minimal vascular flows of ≥1 ml/min cause a significant heat sink effect in hepatic RFA ex vivo. A lower limit for volumetric flow rate was not found. The maximum of the heat sink effect was reached at a flow rate of 10 ml/min and remained stable for flow rates up to 1,500 ml/min. Hepatic inflow occlusion should be considered in RFA close to hepatic vessels. © 2016 Japanese Society of Hepato-Biliary-Pancreatic Surgery.

  2. Numerical investigation of MHD flow of blood and heat transfer in a stenosed arterial segment

    Science.gov (United States)

    Majee, Sreeparna; Shit, G. C.

    2017-02-01

    A numerical investigation of unsteady flow of blood and heat transfer has been performed with an aim to provide better understanding of blood flow through arteries under stenotic condition. The blood is treated as Newtonian fluid and the arterial wall is considered to be rigid having deposition of plaque in its lumen. The heat transfer characteristic has been analyzed by taking into consideration of the dissipation of energy due to applied magnetic field and the viscosity of blood. The vorticity-stream function formulation has been adopted to solve the problem using implicit finite difference method by developing well known Peaceman-Rachford Alternating Direction Implicit (ADI) scheme. The quantitative profile analysis of velocity, temperature and wall shear stress as well as Nusselt number is carried out over the entire arterial segment. The streamline and temperature contours have been plotted to understand the flow pattern in the diseased artery, which alters significantly in the downstream of the stenosis in the presence of magnetic field. Both the wall shear stress and Nusselt number increases with increasing magnetic field strength. However, wall shear stress decreases and Nusselt number enhances with Reynolds number. The results show that with an increase in the magnetic field strength upto 8 T, does not causes any damage to the arterial wall, but the study is significant for assessing temperature rise during hyperthermic treatment.

  3. Analysis of the flow in stenosed carotid artery bifurcation models--hydrogen-bubble visualisation.

    Science.gov (United States)

    Palmen, D E; van de Vosse, F N; Janssen, J D; van Dongen, M E

    1994-05-01

    This paper deals with the effect of geometric changes of mild stenoses on large-scale flow disturbances in the carotid artery bifurcation. Hydrogen-bubble visualisation experiments have been performed in Plexiglas models of a non-stenosed and a 25% stenosed carotid artery bifurcation. The flow conditions approximate physiological flow. The experiments show that shortly after the onset of the diastolic phase vortex formation occurs in the plane of symmetry. This vortex formation is found in a shear layer, which is formed in the carotid sinus. The shear layer is located between a region with low shear rates at the non-divider wall and a region with high shear rates at the divider wall. In order to gain insight into the parameters that are important with respect to the stability of the shear layer, experiments have been performed in which the influence of the shape of the flow pulse, the Reynolds number (Re), the Womersley parameter (alpha) and the flow division ratio (gamma) on the flow phenomena is studied. From these experiments it appears that the flow phenomena in the carotid artery bifurcation are significantly influenced by Re, alpha the systolic acceleration (sa) and deceleration (sd) and the duration of the peak-systolic flow (Tmax). With these results a simplified flow pulse is chosen, with which the experiments in the non-stenosed and the 25% stenosed bifurcation are performed. Comparison of the hydrogen-bubble profiles in the 0 and 25% stenosed models with similar flow conditions shows that the geometric change of the 25% stenosis only slightly influences the flow phenomena. The most striking influences are found in the stability of the shear layer. Quantitative experiments by means of laser Doppler anemometry measurements and numerical computations are needed to analyse the influence of the stenosis of the flow field more accurately.

  4. Hepatic blood flow mapping by dynamic CT method in liver diseases

    International Nuclear Information System (INIS)

    Sugano, Shigeo; Mizuyosi, Hideo; Okajima, Tsugio; Ishii, Kouji; Abei, Tohru; Machida, Keiichi

    1986-01-01

    Two parameters of dynamic CT, peak time (PT) and first moment (M1), were compared among healthy control, chronic hepatitis (CH) and liver cirrhosis (LC). The means of PT and M1 in each 9 (3 x 3) pixels on a slice of hepatic CT were computed and converted to gray spots by gray scale, so that deep gray represented high values and light gray low values of these parameters. The distribution of these gray spots in each pixels was depicted on the slice as a blood flow mapping, and it was compared among the groups. In normal control, dynamic CT showed the shortest PT and deep gray spots were distributed diffusely in the slice. In CH, where PT was longer than control, lighter gray spots were diffusely seen. LC had the longest PT and its mapping showed mottles of light gray and black, the latter indicating the presence of spots with scanty blood flow, scattering throughout the slice. The mapping of M1 gave almost the same picture as PT for each group, revieling that the disappearring time of the media in CH and LC was impaired in the same manner as in PT. This method of hepatic blood flow mapping was thought to be useful to add evidences for the understanding of abnormal blood flow in liver diseases. (author)

  5. Splanchnic blood flow and hepatic glucose production in exercising humans

    DEFF Research Database (Denmark)

    Bergeron, R; Kjaer, M; Simonsen, L

    2001-01-01

    The study examined the implication of the renin-angiotensin system (RAS) in regulation of splanchnic blood flow and glucose production in exercising humans. Subjects cycled for 40 min at 50% maximal O(2) consumption (VO(2 max)) followed by 30 min at 70% VO(2 max) either with [angiotensin-converti......The study examined the implication of the renin-angiotensin system (RAS) in regulation of splanchnic blood flow and glucose production in exercising humans. Subjects cycled for 40 min at 50% maximal O(2) consumption (VO(2 max)) followed by 30 min at 70% VO(2 max) either with [angiotensin......-converting enzyme (ACE) blockade] or without (control) administration of the ACE inhibitor enalapril (10 mg iv). Splanchnic blood flow was estimated by indocyanine green, and splanchnic substrate exchange was determined by the arteriohepatic venous difference. Exercise led to an approximately 20-fold increase (P ...-blockade group vs. the control group, hormones, metabolites, VO(2), and RER followed the same pattern of changes in ACE-blockade and control groups during exercise. Splanchnic blood flow (at rest: 1.67 +/- 0.12, ACE blockade; 1.59 +/- 0.18 l/min, control) decreased during moderate exercise (0.78 +/- 0.07, ACE...

  6. Hepatic artery aneurysm simulating a lesion in the head of the pancreas: a case report; Aneurisma de arteria hepatica simulando lesao em cabeca de pancreas: relato de caso

    Energy Technology Data Exchange (ETDEWEB)

    Pinto, Oswaldo Luiz; Camargo, Jose Gonzaga [Pontificia Univ. Catolica de Campinas, SP (Brazil). Dept. de Cirurgia; Tornin, Olger de Souza; Botelho, Renato Assayag; Menezes, Marcelo Carneiro [Complexo Hospitalar Heliopolis, Sao Paulo, SP (Brazil). Residencia Medica em Radiologia e Diagnostico por Imagem]. E-mail: olger@ibest.com.br; Chagas, Jose Francisco Sales [Complexo Hospitalar Heliopolis, Sao Paulo, SP (Brazil). Curso de Pos-graduacao em Ciencias da Saude; Souza, Ricardo Pires de [Complexo Hospitalar Heliopolis, Sao Paulo, SP (Brazil). Curso de Pos-graduacao em Ciencias da Saude

    2005-12-01

    The aim of this study is to report a rare case of hepatic artery aneurysm simulating a lesion in the head of the pancreas. A precise evaluation using computed tomography and magnetic resonance imaging is important in the treatment planning, which will influence the prognosis. (author)

  7. Portal vein ligation is as effective as sequential portal vein and hepatic artery ligation in inducing contralateral liver hypertrophy in a rat model

    NARCIS (Netherlands)

    Veteläinen, Reeta; Dinant, Sander; van Vliet, Arlène; van Gulik, Thomas M.

    2006-01-01

    PURPOSE: Dual embolization of the hepatic artery and portal vein (PV) has been proposed to enhance contralateral liver regeneration before resection. The aim of this study was to evaluate the effect of PV ligation compared with simultaneous or sequential dual ligation on regeneration,

  8. Investigation of spiral blood flow in a model of arterial stenosis.

    Science.gov (United States)

    Paul, Manosh C; Larman, Arkaitz

    2009-11-01

    The spiral component of blood flow has both beneficial and detrimental effects in human circulatory system [Stonebridge PA, Brophy CM. Spiral laminar flow in arteries? Lancet 1991; 338: 1360-1]. We investigate the effects of the spiral blood flow in a model of three-dimensional arterial stenosis with a 75% cross-sectional area reduction at the centre by means of computational fluid dynamics (CFD) techniques. The standard k-omega model is employed for simulation of the blood flow for the Reynolds number of 500 and 1000. We find that for Re=500 the spiral component of the blood flow increases both the total pressure and velocity of the blood, and some significant differences are found between the wall shear stresses of the spiral and non-spiral induced flow downstream of the stenosis. The turbulent kinetic energy is reduced by the spiral flow as it induces the rotational stabilities in the forward flow. For Re=1000 the tangential component of the blood velocity is most influenced by the spiral speed, but the effect of the spiral flow on the centreline turbulent kinetic energy and shear stress is mild. The results of the effects of the spiral flow are discussed in the paper along with the relevant pathological issues.

  9. Vasoactive enzymes and blood flow responses to passive and active exercise in peripheral arterial disease

    DEFF Research Database (Denmark)

    Walker, Meegan A.; Høier, Birgitte; Walker, Philip J.

    2016-01-01

    Background: Peripheral arterial disease (PAD) is characterised by impaired leg blood flow, which contributes to claudication and reduced exercise capacity. This study investigated to what extent vasoactive enzymes might contribute to altered blood flow in PAD (Fontaine stage II). Methods: We...... compared femoral artery blood flow during reactive hyperaemia, leg-extension exercise and passive leg movement, and determined the level of vasoactive enzymes in skeletal muscle samples from the vastus lateralis in PAD (n = 10, 68.5 ± 6.5 years) and healthy controls (CON, n = 9, 62.1 ± 12.3 years). Leg...... than CON (1.04 ± 0.19 vs 0.50 ± 0.06 AU, P = 0.02), with no differences for other enzymes. Leg blood flow during exercise was correlated with prostacyclin synthase (P = 0.001). Conclusion: Elevated NADPH oxidase indicates that oxidative stress may be a primary cause of low nitric oxide availability...

  10. External carotid artery flow maintains near infrared spectroscopy-determined frontal lobe oxygenation during ephedrine administration

    DEFF Research Database (Denmark)

    Sørensen, H; Rasmussen, P; Sato, K

    2014-01-01

    O₂ by 10.5 (8.2-12.9%; Padministration of ephedrine while SinvosO₂ and SavO₂ decreased [by 3.1 (0.7-4.5%; P=0.017) and 2.1 (0.5-3.3%; P=0.......012)] as arterial carbon dioxide pressure decreased (P=0.003). ICAf was stable and ECAf increased by 11 (4-18%; P=0.005) with administration of ephedrine while SskinO₂ did not change. CONCLUSIONS: The effect of phenylephrine on ScO₂ is governed by a decrease in external carotid blood flow since it increases...... cerebral blood flow as determined by flow in the internal carotid artery. In contrast, ScO₂ is largely maintained with administration of ephedrine because blood flow to extracerebral tissue increases....

  11. A Short Introduction to Arterial Spin Labeling and its Application to Flow Territory Mapping.

    Science.gov (United States)

    Lindner, T; Helle, M; Jansen, O

    2015-10-01

    Arterial spin labeling (ASL) is an emerging method for the assessment of perfusion in various diseases of the brain. In ASL, the magnetization of arterial blood water spins is manipulated in a complete non-invasive way before flowing into the tissue of interest. This allows absolute quantification of cerebral blood flow, thereby, presenting an alternative to contrast-enhanced methods based on computed tomography or magnetic resonance imaging. Furthermore, its potential application for flow territory mapping can provide additional information of the individual configuration of intracerebral blood flow. This article gives a brief overview of the basic ASL methodology and its approaches to image individual perfusion territories. Additionally, the utilization of ASL in a variety of cerebrovascular diseases is presented to provide examples of potential applications of (territorial) ASL in clinical routine.

  12. Continuous stroke volume monitoring by modelling flow from non-invasive measurement of arterial pressure in humans under orthostatic stress

    NARCIS (Netherlands)

    Harms, M.P.M.; Wesseling, K.H.; Pott, F.; Jenstrup, M.; Goudoever, J. van; Secher, N.H.; Lieshout, J.J. van

    1999-01-01

    The relationship between aortic flow and pressure is described by a three-element model of the arterial input impedance, including continuous correction for variations in the diameter and the compliance of the aorta (Modelflow). We computed the aortic flow from arterial pressure by this model, and

  13. Changes in cerebral artery blood flow velocity after intermittent cerebrospinal fluid drainage.

    OpenAIRE

    Kempley, S T; Gamsu, H R

    1993-01-01

    Doppler ultrasound was used to measure blood flow velocity in the anterior cerebral artery of six premature infants with posthaemorrhagic hydrocephalus, before and after intermittent cerebrospinal fluid (CSF) drainage, on 23 occasions. There was a significant increase in mean blood flow velocity after the drainage procedures (+5.6 cm/s, 95% confidence interval +2.9 to +8.3 cm/s), which was accompanied by a decrease in velocity waveform pulsatility. CSF pressure also fell significantly. In pat...

  14. Dependence of renal blood flow on renal artery stenosis measured using CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Luedemann, Lutz [Charite - Universitaetsmedizin Berlin (Germany). Dept. of Radiotherapy; Nafz, B.; Persson, P. [Charite - Universitaetsmedizin Berlin (Germany). Inst. for Vegetative Physiology; Elsner, F. [Krankenhaus am Urban, Berlin (Germany). Dept. of Anesthesiology; Grosse-Siestrup, C.; Meissler, M. [Charite - Universitaetsmedizin Berlin (Germany). Experimental Animal Unit; Gutberlet, M. [Charite - Universitaetsmedizin Berlin (Germany). Dept. of Diagnostic and Interventional Radiology; Univ. Leipzig/ Leipzig Heart Center (Germany). Dept. of Diagnostic and Interventional Radiology; Lengsfeld, P.; Voth, M. [Bayer-Schering Pharma AG, Berlin (Germany). Global Medical Affairs Diagnostic Imaging

    2011-03-15

    The present study investigates the suitability of computed tomography angiography (CTA) depicting the degree of renal artery stenosis for estimating renal blood flow (RBF) in a kidney. Materials and Methods: We investigated renal artery stenosis assessment by CTA in eight adult female hybrid pigs with an ultrasound probe implanted at the renal vein for RBF measurement. An inflatable metal-free cuff was placed around the renal artery to control the RBF. The RBF was then reduced in four steps. For each reduced RBF value and baseline RBF, CTA with a reconstructed slice thickness of 0.625 mm was performed in the arterial phase following injection of 80 ml of nonionic intravenous contrast medium. The radius of the stenotic and non-stenotic renal artery segment was measured in the reconstructed images. Results: A significant linear correlation (p < 0.0001) was found between the relative apparent stenosis (calculated as the ratio of the radii of the actual stenotic segment and a non-stenotic renal artery segment) and RBF. The linear regression yielded a slope of 0.57 and a y-axis of 24.1 %. A significant linear correlation (p < 0.0001) was also found between the relative true stenosis (the ratio of the radii of the actual stenotic segment and a non-stenotic renal artery segment at baseline) and the RBF. The linear regression yielded a slope of 0.67 and a y-axis of 13.8 %. Conclusion: The results show that the relative stenosis apparent on CTA differs from the true degree of renal artery stenosis. Nevertheless, the degree of renal artery stenosis determined by CTA provides a reliable estimate of the resulting RBF reduction. (orig.)

  15. Dependence of renal blood flow on renal artery stenosis measured using CT angiography

    International Nuclear Information System (INIS)

    Luedemann, Lutz; Nafz, B.; Persson, P.; Elsner, F.; Grosse-Siestrup, C.; Meissler, M.; Gutberlet, M.; Univ. Leipzig/ Leipzig Heart Center; Lengsfeld, P.; Voth, M.

    2011-01-01

    The present study investigates the suitability of computed tomography angiography (CTA) depicting the degree of renal artery stenosis for estimating renal blood flow (RBF) in a kidney. Materials and Methods: We investigated renal artery stenosis assessment by CTA in eight adult female hybrid pigs with an ultrasound probe implanted at the renal vein for RBF measurement. An inflatable metal-free cuff was placed around the renal artery to control the RBF. The RBF was then reduced in four steps. For each reduced RBF value and baseline RBF, CTA with a reconstructed slice thickness of 0.625 mm was performed in the arterial phase following injection of 80 ml of nonionic intravenous contrast medium. The radius of the stenotic and non-stenotic renal artery segment was measured in the reconstructed images. Results: A significant linear correlation (p < 0.0001) was found between the relative apparent stenosis (calculated as the ratio of the radii of the actual stenotic segment and a non-stenotic renal artery segment) and RBF. The linear regression yielded a slope of 0.57 and a y-axis of 24.1 %. A significant linear correlation (p < 0.0001) was also found between the relative true stenosis (the ratio of the radii of the actual stenotic segment and a non-stenotic renal artery segment at baseline) and the RBF. The linear regression yielded a slope of 0.67 and a y-axis of 13.8 %. Conclusion: The results show that the relative stenosis apparent on CTA differs from the true degree of renal artery stenosis. Nevertheless, the degree of renal artery stenosis determined by CTA provides a reliable estimate of the resulting RBF reduction. (orig.)

  16. Renal artery blood flow assessed by video dilution technique before and after percutaneous transluminal angioplasty

    International Nuclear Information System (INIS)

    Lantz, B.M.T.; Link, D.P.; Lewis, E.L.; Foerster, J.M.; Lee, G.

    1981-01-01

    Successful percutaneous transluminal angioplasty was performed in 3 cases of renal artery stenosis where the effect upon renal blood flow was quantified by video dilution technique. This technique adds important information to pressure gradients and renin assays obtained during the dilatation procedure. (Auth.)

  17. The clinical use of objective quantification of flow disturbance in carotid artery disease

    DEFF Research Database (Denmark)

    Sillesen, H; Bitsch, K; Steenberg, H J

    1987-01-01

    In order to assess the accuracy of objective quantification of carotid flow disturbance, 147 carotid arteries were examined with continuous wave (CW) Doppler technique. The systolic spectral broadening index (SBI), determined as (maximum-mean)/maximum frequency, was calculated from the power...

  18. Noninvasive arterial blood pressure waveforms in patients with continuous-flow left ventricular assist devices

    NARCIS (Netherlands)

    Martina, Jerson R.; Westerhof, Berend E.; de Jonge, Nicolaas; van Goudoever, Jeroen; Westers, Paul; Chamuleau, Steven; van Dijk, Diederik; Rodermans, Ben F. M.; de Mol, Bas A. J. M.; Lahpor, Jaap R.

    2014-01-01

    Arterial blood pressure and echocardiography may provide useful physiological information regarding cardiac support in patients with continuous-flow left ventricular assist devices (cf-LVADs). We investigated the accuracy and characteristics of noninvasive blood pressure during cf-LVAD support.

  19. Experimental study of CT perfusion in hepatitis, hepatic fibrosis and early stage of cirrhosis

    International Nuclear Information System (INIS)

    Guan Sheng; Zhao Weidong; Zhou Kangrong; Peng Weijun; Mao Jian; Tang Feng; Wang Yong; Cao Guang; Sun Fei

    2005-01-01

    Objective: To investigate the value of CT perfusion in the early diagnosis of hepatic diffuse disease. Methods: Fourteen male Wistar rats of control group and 14 of test group at stages of hepatitis, hepatic fibrosis, hepatic cirrhosis which were induced with diethylnitrosamine (DEN), were studied with CT perfusion respectively. CT perfusion data of different stages were compared and pathologic analysis were performed. Results: Density-time curves of CT perfusion were satisfactory and all perfusion data could be obtained. During the period of hepatitis developing into early stage of hepatic cirrhosis, hepatic artery flow (HAF) trended to increase in test group, mean transmit time (MTT) prolonged obviously, blood flow (BF) and volume (BV) declined. While in control group, HAF declined slightly, MTT, BV and BF increased. Statistic analysis showed the differences of HAF and MTT at different stages between control and test groups were significant (P<0.05 ); the differences of BV and BF between hepatitis and hepatic cirrhosis, hepatic fibrosis and early stage of hepatic cirrhosis in test group were significant (P<0.05), but no significant difference between hepatitis and hepatic fibrosis. The corresponding pathologic changes at stage of hepatitis was swelling of hepatic cells; sinusoids cap illarization and deposition of collagen in the extravascular Disse's spaces were the main changes relating to hepatic blood perfusion at stage of fibrosis and early stage of cirrhosis. Conclusion: The method of CT scan can reflect some changes of hepatic blood perfusion in rats with hepatitis, hepatic fibrosis and early stage of cirrhosis. The data of CT perfusion, especially the changes should be valuable for clinical early diagnosis, treatment and follow-up. (authors)

  20. Angiographic Assessment of the Right Hepatic Artery for Encasement by Hilar Cholangiocarcinoma: Comparison Between Antero-Posterior and Right Anterior Oblique Projections

    International Nuclear Information System (INIS)

    Furukawa, Hiroyoshi; Iwata, Ryoko; Moriyama, Noriyuki

    2001-01-01

    Purpose: To evaluate the usefulness of right anterior oblique (RAO) arteriography for evaluating encasement of the right hepatic artery (RHA) by hilar cholangiocarcinoma.Methods: Celiac arteriography was performed in both the antero-posterior (AP) and RAO projection in ten patients with cholangiocarcinoma. The lengths of the arteries between the bifurcation of the anterior and posterior branch of the liver and the following points were measured: (a) the bifurcation of the left and right hepatic artery (AP-LR), (b) the bifurcation of the proper hepatic artery and the gastroduodenal artery (AP-PG). Additionally, image quality in investigating the invasion of the RHA was evaluated.Results: On the AP images, the average lengths of AP-LR and AP-PG were 24.5 ± 5.1 mm and 30.0 ± 4.9 mm, respectively. On RAO images, the lengths were 28.2 ± 4.6 mm and 32.7 ± 4.8 mm, respectively. Every length was different between the two projections (p < 0.01). In 6 of 10 patients with hilar cholangiocarcinoma, images in RAO projections were superior to AP images for evaluation of encasement.Conclusion: We conclude that angiography obtained in the RAO projection yields images that are superior to those obtained in the conventional AP projection for assessment of RHA encasement

  1. Angiographic visualization of a spurious aneurism of the common hepatic artery

    Energy Technology Data Exchange (ETDEWEB)

    Fobbe, F.; Wolf, K.J.

    1987-01-01

    Pseudoaneurisms of the artery in chronic pancreatitis are rare complications that are not detected by conventional ultrasonography. The article reports a case where an aneurisma spurium of the A. gastroduodenalis has been detected by means of angiodynography.

  2. Angiohepatogram in diffuse hepatic disease

    International Nuclear Information System (INIS)

    Aburano, Tamio; Suzuki, Yutaka; Hisada, Kinichi; Matsudaira, Masamichi.

    1975-01-01

    A region of interest angiohepatogram was obtained with intravenous injection of 10mCi of sup(99m)Tc-Sn-colloid and a data processing system. Furthermore, the ratio of hepatic arterial blood flow volume to total hepatic blood flow volume was calculated according to Ueda's method, and the correlation of this calculated ratio and the degree of extrahepatic distribution of sup(99m)Tc-Sn-colloid (spleen to liver, and bone marrow to liver activity ratio) was examined. Most cases of liver cirrhosis and Banti's syndrome showed the increased hepatic arterial blood flow ratio (liver cirrhosis: 43.5+-9.5%, Banti's syndrome 48.8+-4.9%) in contrast with 18.1+-4.6% in normal cases, and its ratio showed much higher values in the presence of portal hypertension manifestations (esophageal varix and ascites). The hepatic arterial blood flow ratio showed increased values in the case of markedly increased extrahepatic activity, e.g. liver cirrhosis, and the correlation of the ratio and extrahepatic activity degree of sup(99m)Tc-Sn-colloid was significant statistically. From these results, a region of interest angiohepatogram was supposed to be useful for the prediction of the hemodynamic change, as well as, the improvement of diagnostic accuracy with radioisotope in diffuse hepatic disease, especially liver cirrhosis. Moreover, the hemodynamic change of liver, especially the reduction of the effective hepatic blood flow volume via the portal vein was considered to be closely concerned in the mechanism of increased extrahepatic activity of RI colloid in diffuse hepatic disease. (auth.)

  3. Two-Fluid Mathematical Models for Blood Flow in Stenosed Arteries: A Comparative Study

    Directory of Open Access Journals (Sweden)

    Sankar DS

    2009-01-01

    Full Text Available The pulsatile flow of blood through stenosed arteries is analyzed by assuming the blood as a two-fluid model with the suspension of all the erythrocytes in the core region as a non-Newtonian fluid and the plasma in the peripheral layer as a Newtonian fluid. The non-Newtonian fluid in the core region of the artery is assumed as a (i Herschel-Bulkley fluid and (ii Casson fluid. Perturbation method is used to solve the resulting system of non-linear partial differential equations. Expressions for various flow quantities are obtained for the two-fluid Casson model. Expressions of the flow quantities obtained by Sankar and Lee (2006 for the two-fluid Herschel-Bulkley model are used to get the data for comparison. It is found that the plug flow velocity and velocity distribution of the two-fluid Casson model are considerably higher than those of the two-fluid Herschel-Bulkley model. It is also observed that the pressure drop, plug core radius, wall shear stress and the resistance to flow are significantly very low for the two-fluid Casson model than those of the two-fluid Herschel-Bulkley model. Hence, the two-fluid Casson model would be more useful than the two-fluid Herschel-Bulkley model to analyze the blood flow through stenosed arteries.

  4. Can flavonoid-rich chocolate modulate arterial elasticity and pathological uterine artery Doppler blood flow in pregnant women? A pilot study.

    Science.gov (United States)

    von Wowern, Emma; Olofsson, Per

    2018-09-01

    Dark chocolate has shown beneficial effects on cardiovascular health and might also modulate hypertensive complications in pregnancy and uteroplacental blood flow. Increased uteroplacental resistance is associated with systemic arterial stiffness. We aimed to investigate the short-term effect of flavonoid-rich chocolate on arterial stiffness and Doppler blood flow velocimetry indexes in pregnant women with compromised uteroplacental blood flow. Doppler blood flow velocimetry and digital pulse wave analysis (DPA) were performed in 25 women pregnant in the second and third trimesters with uterine artery (UtA) score (UAS) 3-4, before and after 3 days of ingestion of chocolate with high flavonoid and antioxidant contents. UtA pulsatility index (PI), UtA diastolic notching, UAS (semiquantitative measure of PI and notching combined), and umbilical artery PI were calculated, and DPA variables representing central and peripheral maternal arteries were recorded. Mean UtA PI (p = .049) and UAS (p = .025) significantly decreased after chocolate consumption. There were no significant changes in UtA diastolic notching or any DPA indexes of arterial stiffness/vascular tone. Chocolate may have beneficial effects on the uteroplacental circulation, but in this pilot study, we could not demonstrate effects on arterial vascular tone as assessed by DPA.

  5. Hepatic blood perfusion estimated by dynamic contrast-enhanced computed tomography in pigs

    DEFF Research Database (Denmark)

    Winterdahl, Michael; Sørensen, Michael; Keiding, Inger Susanne

    2012-01-01

    The aim of this study was to determine whether dynamic contrast-enhanced computed tomography (DCE-CT) and the slope method can provide absolute measures of hepatic blood perfusion from the hepatic artery (HA) and portal vein (PV) at experimentally varied blood flow rates.......The aim of this study was to determine whether dynamic contrast-enhanced computed tomography (DCE-CT) and the slope method can provide absolute measures of hepatic blood perfusion from the hepatic artery (HA) and portal vein (PV) at experimentally varied blood flow rates....

  6. An effective fractal-tree closure model for simulating blood flow in large arterial networks.

    Science.gov (United States)

    Perdikaris, Paris; Grinberg, Leopold; Karniadakis, George Em

    2015-06-01

    The aim of the present work is to address the closure problem for hemodynamic simulations by developing a flexible and effective model that accurately distributes flow in the downstream vasculature and can stably provide a physiological pressure outflow boundary condition. To achieve this goal, we model blood flow in the sub-pixel vasculature by using a non-linear 1D model in self-similar networks of compliant arteries that mimic the structure and hierarchy of vessels in the meso-vascular regime (radii [Formula: see text]). We introduce a variable vessel length-to-radius ratio for small arteries and arterioles, while also addressing non-Newtonian blood rheology and arterial wall viscoelasticity effects in small arteries and arterioles. This methodology aims to overcome substantial cut-off radius sensitivities, typically arising in structured tree and linearized impedance models. The proposed model is not sensitive to outflow boundary conditions applied at the end points of the fractal network, and thus does not require calibration of resistance/capacitance parameters typically required for outflow conditions. The proposed model convergences to a periodic state in two cardiac cycles even when started from zero-flow initial conditions. The resulting fractal-trees typically consist of thousands to millions of arteries, posing the need for efficient parallel algorithms. To this end, we have scaled up a Discontinuous Galerkin solver that utilizes the MPI/OpenMP hybrid programming paradigm to thousands of computer cores, and can simulate blood flow in networks of millions of arterial segments at the rate of one cycle per 5 min. The proposed model has been extensively tested on a large and complex cranial network with 50 parent, patient-specific arteries and 21 outlets to which fractal trees where attached, resulting to a network of up to 4,392,484 vessels in total, and a detailed network of the arm with 276 parent arteries and 103 outlets (a total of 702,188 vessels

  7. 5-Fluorouracil incorporation into RNA of a rat liver adenocarcinoma after hepatic artery injection together with degradable starch microspheres

    International Nuclear Information System (INIS)

    Teder, H.; Erichsen, C.; Christensson, P.I.; Joensson, P.E.S.; Stenram, U.

    1987-01-01

    The effect of degradable starch microspheres (DSM) on the cellular incorporation of 5-fluorouracil (FUra) was studied in rats with solitary liver tumors. 3 H-labelled FUra [0.78 mg (6000 nmol)/kg b.wt.] was injected with saline or mixed with DSM, into the hepatic artery. Labelling of the acid soluble fraction (ASF), RNA and DNA of tumor, liver, bone marrow and small intestine was measured 60 minutes after injection. The DSM had no significant effect on the incorporation of FUra into the ASF or RNA, neither in tumor nor liver tissue. Regarding the tumor/normal tissue ratios of specific radioactivities, there was with DSM a higher tumor/liver and a higher tumor/bone marrow ratio in the ASF, indicating an increased tumour drug exposure with DSM. However, this was not accompanied by any significant increase in drug anabolism

  8. Evaluation of arterial digital blood flow using Doppler ultrasonography in healthy dairy cows.

    Science.gov (United States)

    Müller, H; Heinrich, M; Mielenz, N; Reese, S; Steiner, A; Starke, A

    2017-06-06

    Local circulatory disturbances have been implicated in the development of foot disorders in cattle. The goals of this study were to evaluate the suitability of the interdigital artery in the pastern region in both hind limbs using pulsed-wave (PW) Doppler ultrasonography and to investigate quantitative arterial blood flow variables at that site in dairy cows. An Esaote MyLabOne ultrasound machine with a 10-MHz linear transducer was used to assess blood flow in the interdigital artery in the pastern region in both hind limbs of 22 healthy German Holstein cows. The cows originated from three commercial farms and were restrained in a standing hoof trimming chute without sedation. A PW Doppler signal suitable for analysis was obtained in 17 of 22 cows. The blood flow profiles were categorised into four curve types, and the following quantitative variables were measured in three uniform cardiac cycles: vessel diameter, pulse rate, maximum systolic velocity, maximum diastolic velocity, end-diastolic velocity, reverse velocity, maximum time-averaged mean velocity, blood flow rate, resistance index and persistence index. The measurements did not differ among cows from the three farms. Maximum systolic velocity, vessel diameter and pulse rate did not differ but other variables differed significantly among blood flow profiles. Differences in weight-bearing are thought to be responsible for the normal variability of blood flow profiles in healthy cows. The scanning technique used in this report for evaluation of blood flow in the interdigital artery appears suitable for further investigations in healthy and in lame cows.

  9. Value of downstream circulation in renal artery stenosis with arterial hypertension: comparison between color Doppler flow and digital renal angiography in 123 patients

    International Nuclear Information System (INIS)

    Grataloup, C.; Challande, P.; Plainfosse, M.C.; Girerd, X.; Belattar, K.; Plouin, P.F.

    1996-01-01

    Digital renal angiography and color Doppler flow were compared for diagnosis of renal artery stenosis in 123 hypertensive patients with a prevalence of renal artery stenosis ≥75% of 21 %. Only color Doppler flow signs found downstream from the stenosis could be quantified. A rising time (RT) >0.07 s was the best marker for renal artery stenosis ≥ 75 % according to a receiver operating characteristic curve with a specificity of 97 %, a sensitivity of 88 %, a positive predictive value of 86 %, a negative predictive value of 98 % and an accuracy of 96 %. Digital renal angiography and color Doppler flow findings for renal artery lesions were classified into 4 degrees with agreement for 86 % of the kidneys. (authors). 13 refs., 5 figs., 8 tabs

  10. Renovascular hypertension due to insufficient collateral flow in segmental artery occulusion

    International Nuclear Information System (INIS)

    Park, Y. H.; Lee, S. Y.; Kim, S. H.; Sohn, H. S.; Chung, S. K.

    2001-01-01

    We report a case in which a 33-year-old woman with renovascular hypertension due to insufficient collateral flow in segmental renal artery occlusion demonstrated abnormality on captopril renal scintigram. Baseline renal scintigram with DTPA showed normal perfusion and excretion in left kidney and captopril renal scintigram with DTPA showed a focal area of decreased perfusion and delayed clearance in lower half of left kidney, suggesting segmental renal artery stenosis. Selective left renal arteriography showed complete obstruction in proximal portion of anterior segmental artery with multiple small collateral vessels from posterior segmental artery and capsular artery and delayed opacification in lower half of left kidney. These findings are suggestive of segmental hypoperfusion due to insufficient collateral blood flow resulting to positive captopril response. Patient's blood pressure have been controlled well with ACE (angiotensin converting enzyme) inhibitor and calcium channel blocker for 2 year. Follow-up baseline renal scintigram with MAG3 showed normal perfusion and excretion in left kidney and captopril renal scintigram with MAG3 showed a focal area of decreased perfusion and delayed clearance in lower lateral portion of left kidney, which was smaller size than that of previous renal scintigram. And captopril renal scintigram with DMSA demonstrated a small area of decreased DMSA uptake on this lesion compared to baseline DMSA scintigram

  11. Clinical factors related to recurrence after hepatic arterial concurrent chemoradiotherapy for advanced but liver-confined hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Cha, Hyejung; Yoon, Hong In; Lee, Ik Jae; Koom, Woong Sub; Seong, Jinsil; Han, Kwang-Hyub

    2013-01-01

    Before the sorafenib era, advanced but liver-confined hepatocellular carcinoma (HCC) was treated by liver-directed therapy. Hepatic arterial concurrent chemoradiotherapy (CCRT) has been performed in our group, giving substantial local control but frequent failure. The aim of this study was to analyze patterns of failure and find out predictive clinical factors in HCC treated with a liver-directed therapy, CCRT. A retrospective analysis was done for 138 HCC patients treated with CCRT between May 2001 and November 2009. Protocol-based CCRT was performed with local radiotherapy (RT) and concurrent 5-fluorouracil (5-FU) hepatic arterial infusion chemotherapy (HAIC), followed by monthly HAIC (5-FU and cisplatin). Patterns of failure were categorized into three groups: infield, intrahepatic-outfield and extrahepatic failure. Treatment failure occurred in 34.0% of patients at 3 months after RT. Infield, intrahepatic-outfield and extrahepatic failure were observed in 12 (8.6%), 26 (18.7%) and 27 (19.6%) patients, respectively. Median progression-free survival for infield, outfield and extrahepatic failure was 22.4, 18 and 21.5 months, respectively. For infield failure, a history of pre-CCRT treatment was a significant factor (P=0.020). Pre-CCRT levels of alpha-fetoprotein and prothrombin induced by vitamin K absence or antagonist-II were significant factors for extrahepatic failure (P=0.029). Treatment failures after CCRT were frequent in HCC patients, and were more commonly intrahepatic-outfield and extrahepatic failures than infield failure. A history of pre-CCRT treatment and levels of pre-CCRT tumor markers were identified as risk factors that could predict treatment failure. More intensified treatment is required for patients presenting risk factors. (author)

  12. Hepatic arterial 90Yttrium glass microspheres (Therasphere) for unresectable hepatocellular carcinoma: interim safety and survival data on 65 patients.

    Science.gov (United States)

    Carr, Brian I

    2004-02-01

    Hepatocellular carcinoma (HCC) generally arises in a cirrhotic liver and, in most cases, is multifocal and bilobar. Although trans-hepatic artery chemoembolization (TACE) can be highly affective in shrinking tumors, it is limited by virtue of the damage that it can cause to the liver that is already damaged by chronic disease. A high priority in HCC research, after primary prevention and early detection, is to find new treatment modalities that are both effective and non-toxic to the underlying cirrhotic liver. A cohort of 65 patients with biopsy-proven unresectable HCC have been treated with hepatic arterial 90Yttrium microspheres (Therasphere), and the interim results are reported here. Only 1 cycle of Therasphere treatment ever was performed on 46 patients, 17 patients had 2 cycles, and 2 patients had 3 cycles of therapy. The median dose delivered was 134 Gy, typically as either 5 or 10 GBq (2-4 million microspheres). Clinical toxicities include 9 episodes of abdominal pain and 2 episodes of acute cholecystitis, requiring cholecystectomy. A main lab toxicity was elevated bilirubin which increased by more than 200% in 25 patients (30.5%) during 6 months of therapy, although 18 of these patients had only transient elevation. A prominent finding was prolonged and profound (>70%) lymphopenia in more than 75% of the patients, but without clinical significance. Forty-two patients (64.6%) had a substantial decrease in tumor vascularity in response to therapy, and 25 patients (38.4%) had a partial response, by computed tomography scan. Median survival for Okuda stage I patients (n=42) was 649 days (historical comparison 244) and for Okuda stage II patients (n=23) was 302 days (historical comparison 64 days). All patients were followed after therapy for a minimum of 6 months. There were 42 deaths, 21 due to liver failure, 6 from HCC progression, and 3 from metastases. Therasphere appears to be a relatively safe and effective therapy for advanced-stage unresectable HCC.

  13. Effect of hypertensive disorders during pregnancy on neonatal outcomes and umbilical artery flow

    Directory of Open Access Journals (Sweden)

    Dong-mei ZHENG

    2013-09-01

    Full Text Available Objective To observe the effect of hypertensive disorders during pregnancy (HDP on neonatal outcomes and umbilical artery flow. Methods A prospective cohort study method was employed, and 60 pregnant women met the HDP diagnostic criteria (HDP group, aged 31.2±6.0 years, gestation time 251.0±9.0d, hospitalized from Sep. 2011 to May. 2012, and delivered live-born infants and 63 pregnant women with normal blood pressure and without medical or surgical ailments (control group, aged 30.2±2.8 years, gestation time 251.9±7.7d, hospitalized in the the same period, and had live birth were involved in present study. The indexes of umbilical artery blood flow were measured, the adverse neonatal outcomes (neonatal asphyxia, low birth weight babies and premature labor were recorded, and the correlation was analyzed between the adverse neonatal outcomes and the indexes of umbilical artery blood flow. Results The incidence of adverse neonatal outcomes (neonatal asphyxia, low birth weight newborns and premature labor was higher in HDP group (58.3%, 45.0% and 53.3%, respectively than in control group (6.3%, 3.2% and 3.2%, respectively, P<0.05. The results of umbilical artery blood flow indexes, including pulsatility index (PI, resistance index (RI and systolic/diastolic ratio (S/D in HDP group (0.897±0.176, 0.588±0.701 and 2.655±0.346, respectively were significantly higher than in control group (0.741±0.123, 0.525±0.650 and 2.120±0.364, respectively, P<0.05. The indexes of umbilical artery blood flow (PI, RI and S/D in newborns with adverse outcomes were significantly higher than in those newborn without adverse outcomes. Multivariate logistic regression revealed a positive correlation between RI and adverse neonatal outcomes. Conclusions The indexes of umbilical artery blood flow appear to be abnormal in pregnant women with HDP, and adverse neonatal conditions (neonatal asphyxia, low birth weight newborns and premature labor are prone to

  14. Pulsatility of Lenticulostriate Arteries Assessed by 7 Tesla Flow MRI-Measurement, Reproducibility, and Applicability to Aging Effect.

    Science.gov (United States)

    Schnerr, Roald S; Jansen, Jacobus F A; Uludag, Kamil; Hofman, Paul A M; Wildberger, Joachim E; van Oostenbrugge, Robert J; Backes, Walter H

    2017-01-01

    Characterization of flow properties in cerebral arteries with 1.5 and 3 Tesla MRI is usually limited to large cerebral arteries and difficult to evaluate in the small perforating arteries due to insufficient spatial resolution. In this study, we assessed the feasibility to measure blood flow waveforms in the small lenticulostriate arteries with 7 Tesla velocity-sensitive MRI. The middle cerebral artery was included as reference. Imaging was performed in five young and five old healthy volunteers. Flow was calculated by integrating time-varying velocity values over the vascular cross-section. MRI acquisitions were performed twice in each subject to determine reproducibility. From the flow waveforms, the pulsatility index and damping factor were deduced. Reproducibility values, in terms of the intraclass correlation coefficients, were found to be good to excellent. Measured pulsatility index of the lenticulostriate arteries significantly increased and damping factor significantly decreased with age. In conclusion, we demonstrate that blood flow through the lenticostriate arteries can be precisely measured using 7 Tesla MRI and reveal effects of arterial stiffness due to aging. These findings hold promise to provide relevant insights into the pathologies involving perforating cerebral arteries.

  15. Experimental study on blood flow patterns through the phantoms of the intracranial arterial aneurysms using color Doppler imaging

    International Nuclear Information System (INIS)

    Chung, Tae Sub; Jeong, Eun Kee; Rhim, Yoon Chul; Kim, Sung Bin; Lee, Dong Hoon; Kim, Dae In

    1994-01-01

    The occurrence, growth, thrombosis, and rupture of intracranial saccular aneurysms can be directly related to the effect of hemodynamic forces. We developed the phantom flow models and compared with the computer simulation program to analyse the flow pattern and hemodynamics that might be responsible for the intracranial arterial aneurysms. We designed the arterial phantoms of three major sites of intracranial arterial aneurysm ; 1) basilar artery tip, 2) internal carotid artery bifurcation, 3) curved area of internal carotid artery. Flow patterns in the aneurysmal portion of phantoms were evaluated with color Doppler system on the connection with automatic closed type of circulation system. Then, we compared the results with computer simulation. The hemodynamic characteristics of the phantoms were identical with those obtained by computerisation's. Three distinct zones of flow were identified by color Doppler studies on the aneurysm of the curved area of an internal carotid artery : 1) an inflow zone entering the aneurysm at the distal aspect of its orifice, 2) an outflow zone exiting the aneurysm at the proximal aspect of its orifice, 3) a central slow vortex.However, the phantoms of basilar artery tip and artery bifurcation showed a direct inflow stream at the dome of an aneurysm. Flow dynamics in the various phantoms of the aneurysms can be successfully evaluated with color Doppler imaging, and were consistent with those predicted by computer simulations

  16. Increased prevalence of coronary artery disease risk markers in patients with chronic hepatitis C

    DEFF Research Database (Denmark)

    Roed, Torsten; Kristoffersen, Ulrik Sloth; Knudsen, Andreas

    2014-01-01

    % confidence interval [CI] 0.9-2.7) and smoked more (53% versus 38%, PR 1.4; 95% CI 0.9-2.1). The two groups had similar body mass index (mean 25.0 versus 25.7 kg/m(2)), whereas those with chronic hepatitis C had less dyslipidemia (including significantly lower low-density lipoprotein and cholesterol...

  17. Mass-forming intrahepatic cholangiocarcinoma: Enhancement patterns in the arterial phase of dynamic hepatic CT - Correlation with clinicopathological findings

    Energy Technology Data Exchange (ETDEWEB)

    Fujita, Nobuhiro; Asayama, Yoshiki; Nishie, Akihiro; Ishigami, Kousei; Ushijima, Yasuhiro; Okamoto, Daisuke; Moirta, Koichiro; Honda, Hiroshi [Kyushu University, Department of Clinical Radiology, Graduate School of Medical Sciences, Higashi-ku, Fukuoka (Japan); Takayama, Yukihisa [Kyushu University, Department of Radiology Informatics and Network, Graduate School of Medical Sciences, Higashi-ku, Fukuoka (Japan); Shirabe, Ken [Kyushu University, Department of Surgery and Science, Graduate School of Medical Sciences, Higashi-ku, Fukuoka (Japan); Aishima, Shinichi [Saga University Hospital, Department of Pathology and Microbiology, Faculty of Medicine, Saga City, Saga (Japan); Wang, Huanlin; Oda, Yoshinao [Kyushu University, Department of Anatomic Pathology, Graduate School of Medical Sciences, Higashi-ku, Fukuoka (Japan)

    2017-02-15

    To evaluate the relationship between the enhancement pattern of intrahepatic cholangiocarcinomas (ICCs) in the hepatic arterial phase (HAP) of dynamic hepatic CT and the clinicopathological findings with special reference to the perihilar type and the peripheral type. Forty-seven patients with pathologically proven ICCs were enrolled. Based on the enhancement pattern in the HAP, the lesions were classified into three groups: a hypovascular group (n=13), rim-enhancement group (n=18), and hypervascular group (n=16). The clinicopathological findings were compared among the three groups. Perihilar-type ICCs were significantly more frequently observed in the hypovascular group than in the rim-enhancement and hypervascular groups (p=0.006 and p <0.001, respectively). Lymphatic invasion, perineural invasion, and biliary invasion were significantly more frequent in the hypovascular group than the rim- enhancement group (p=0.001, p=0.025 and p=0.029, respectively) or hypervascular group (p <0.001, p <0.001 and p=0.025, respectively). Patients with hypovascular lesions showed significantly poorer disease-free survival than patients with rim-enhancing or hypervascular lesions (p=0.001 and p=0.001, respectively). Hypovascularity was an independent preoperative prognostic factor for disease-free survival (p<0.001). Hypovascular ICCs in the HAP tend to be of perihilar type and to have more malignant potential than other ICCs. (orig.)

  18. Luminal flow amplifies stent-based drug deposition in arterial bifurcations.

    Directory of Open Access Journals (Sweden)

    Vijaya B Kolachalama

    2009-12-01

    Full Text Available Treatment of arterial bifurcation lesions using drug-eluting stents (DES is now common clinical practice and yet the mechanisms governing drug distribution in these complex morphologies are incompletely understood. It is still not evident how to efficiently determine the efficacy of local drug delivery and quantify zones of excessive drug that are harbingers of vascular toxicity and thrombosis, and areas of depletion that are associated with tissue overgrowth and luminal re-narrowing.We constructed two-phase computational models of stent-deployed arterial bifurcations simulating blood flow and drug transport to investigate the factors modulating drug distribution when the main-branch (MB was treated using a DES. Simulations predicted extensive flow-mediated drug delivery in bifurcated vascular beds where the drug distribution patterns are heterogeneous and sensitive to relative stent position and luminal flow. A single DES in the MB coupled with large retrograde luminal flow on the lateral wall of the side-branch (SB can provide drug deposition on the SB lumen-wall interface, except when the MB stent is downstream of the SB flow divider. In an even more dramatic fashion, the presence of the SB affects drug distribution in the stented MB. Here fluid mechanic effects play an even greater role than in the SB especially when the DES is across and downstream to the flow divider and in a manner dependent upon the Reynolds number.The flow effects on drug deposition and subsequent uptake from endovascular DES are amplified in bifurcation lesions. When only one branch is stented, a complex interplay occurs - drug deposition in the stented MB is altered by the flow divider imposed by the SB and in the SB by the presence of a DES in the MB. The use of DES in arterial bifurcations requires a complex calculus that balances vascular and stent geometry as well as luminal flow.

  19. MR velocity mapping measurement of renal artery blood flow in patients with impaired kidney function

    DEFF Research Database (Denmark)

    Cortsen, M; Petersen, L.J.; Stahlberg, F

    1996-01-01

    Renal blood flow (RBF) was measured in 9 patients with chronic impaired kidney function using MR velocity mapping and compared to PAH clearance and 99mTc-DTPA scintigraphy. An image plane suitable for flow measurement perpendicular to the renal arteries was chosen from 2-dimensional MR angiography....... MR velocity mapping was performed in both renal arteries using an ECG-triggered gradient echo pulse sequence previously validated in normal volunteers. Effective renal plasma flow was calculated from the clearance rate of PAH during constant infusion and the split of renal function was evaluated...... by 99mTc-DTPA scintigraphy. A reduction of RBF was found, and there was a significant correlation between PAH clearance multiplied by 1/(1-hematocrit) and RBF determined by MR velocity mapping. Furthermore, a significant correlation between the distribution of renal function and the percent distribution...

  20. Wall morphology, blood flow and wall shear stress: MR findings in patients with peripheral artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Galizia, Mauricio S.; Barker, Alex; Collins, Jeremy; Carr, James [Northwestern University, Department of Radiology, Feinberg School of Medicine, Chicago, IL (United States); Liao, Yihua [Northwestern University' s Feinberg School of Medicine, Department of Preventive Medicine, Chicago, IL (United States); McDermott, Mary M. [Northwestern University' s Feinberg School of Medicine, Department of Preventive Medicine, Chicago, IL (United States); Northwestern University' s Feinberg School of Medicine, Department of Medicine, Chicago, IL (United States); Markl, Michael [Northwestern University, Department of Radiology, Feinberg School of Medicine, Chicago, IL (United States); Northwestern University, Department Biomedical Engineering, McCormick School of Engineering, Chicago, IL (United States)

    2014-04-15

    To investigate the influence of atherosclerotic plaques on femoral haemodynamics assessed by two-dimensional (2D) phase-contrast (PC) magnetic resonance imaging (MRI) with three-directional velocity encoding. During 1 year, patients with peripheral artery disease and an ankle brachial index <1.00 were enrolled. After institutional review board approval and written informed consent, 44 patients (age, 70 ± 12 years) underwent common femoral artery MRI. Patients with contra-indications for MRI were excluded. Sequences included 2D time-of-flight, proton-density, T1-weighted and T2-weighted MRI. Electrocardiogram (ECG)-gated 2D PC-MRI with 3D velocity encoding was acquired. A radiologist classified images in five categories. Blood flow, velocity and wall shear stress (WSS) along the vessel circumference were quantified from the PC-MRI data. The acquired images were of good quality for interpretation. There were no image quality problems related to poor ECG-gating or slice positioning. Velocities, oscillatory shear stress and total flow were similar between patients with normal arteries and wall thickening/plaque. Patients with plaques demonstrated regionally increased peak systolic WSS and enhanced WSS eccentricity. Combined multi-contrast morphological imaging of the peripheral arterial wall with PC-MRI with three-directional velocity encoding is a feasible technique. Further study is needed to determine whether flow is an appropriate marker for altered endothelial cell function, vascular remodelling and plaque progression. (orig.)

  1. Effect of Acute Resistance Exercise on Carotid Artery Stiffness and Cerebral Blood Flow Pulsatility

    Directory of Open Access Journals (Sweden)

    Wesley K Lefferts

    2014-03-01

    Full Text Available Arterial stiffness is associated with cerebral flow pulsatility. Arterial stiffness increases following acute resistance exercise (RE. Whether this acute RE-induced vascular stiffening affects cerebral pulsatility remains unknown. Purpose: To investigate the effects of acute RE on common carotid artery (CCA stiffness and cerebral blood flow velocity (CBFv pulsatility. Methods: Eighteen healthy men (22 ± 1 yr; 23.7 ± 0.5 kg∙m-2 underwent acute RE (5 sets, 5-RM bench press, 5 sets 10-RM bicep curls with 90 s rest intervals or a time control condition (seated rest in a randomized order. CCA stiffness (β-stiffness, Elastic Modulus (Ep and hemodynamics (pulsatility index, forward wave intensity and reflected wave intensity were assessed using a combination of Doppler ultrasound, wave intensity analysis and applanation tonometry at baseline and 3 times post-RE. CBFv pulsatility index was measured with transcranial Doppler at the middle cerebral artery (MCA. Results: CCA β-stiffness, Ep and CCA pulse pressure significantly increased post-RE and remained elevated throughout post-testing (p 0.05. There were significant increases in forward wave intensity post-RE (p0.05. Conclusion: Although acute RE increases CCA stiffness and pressure pulsatility, it may not affect CCA or MCA flow pulsatility. Increases in pressure pulsatility may be due to increased forward wave intensity and not pressure from wave reflections.

  2. Effects of respiratory manoeuvres on hepatic vein Doppler waveform and flow velocities in a healthy population

    International Nuclear Information System (INIS)

    Altinkaya, Naime; Koc, Zafer; Ulusan, Serife; Demir, Senay; Gurel, Kamil

    2011-01-01

    Objective: This study was performed to determine the variations in Doppler waveforms and flow velocity during respiratory manoeuvres in healthy individuals with no liver disease. Materials and methods: In total, 100 individuals (75 women and 25 men) without known cardiac or liver disease were examined prospectively with duplex Doppler ultrasonography (US). We recorded the Doppler waveforms and peak systolic velocities (V max ) of the middle hepatic vein during normal respiration, during breath-holding after quiet expiration and also during deep inspiration. Doppler waveforms are categorised as triphasic, biphasic or monophasic. Results: During normal respiration, hepatic venous waveforms were triphasic in 93% of subjects, monophasic in 6% and biphasic in 1%. During breath-holding after quiet expiration, the percentages were 91%, 6% and 3%, respectively. During deep inspiration, they were 80%, 18% and 2%, respectively. Although significant differences were noted between rates during deep inspiration and normal respiration, they were quite similar during normal respiration and breath-holding after quiet expiration (P max were significantly higher during normal respiration compared to quiet expiration and during quiet expiration compared to deep inspiration (P < 0.05). Conclusion: The velocities and waveforms of hepatic veins varied during respiratory manoeuvres. The status of respiration must be taken into consideration whilst examining the hepatic vein waveforms and velocities with duplex Doppler US.

  3. Ultrasound analysis of mental artery flow in elderly patients: a case-control study.

    Science.gov (United States)

    Baladi, Marina G; Tucunduva Neto, Raul R C M; Cortes, Arthur R G; Aoki, Eduardo M; Arita, Emiko S; Freitas, Claudio F

    2015-01-01

    Mental artery flow decreases with age and may have an aetiological role in alveolar ridge atrophy. The aim of this study was to identify factors associated with alterations of mental artery flow, assessed by ultrasonography. This case-control study was conducted on elderly patients (aged above 60 years) at the beginning of dental treatment. Intraoral B-mode Doppler ultrasonography was used to assess mental artery flow. The cases were defined as patients with a weak/absent ultrasound signal, whereas the controls presented a strong ultrasound signal. Demographics and radiographic findings (low bone mineral density on dual-energy X-ray absorptiometry and mandibular cortical index on panoramic radiographs) were analysed as risk factors for weak/absent ultrasound signal and were calculated as adjusted odds ratios (AORs) with 95% confidence intervals (CIs) using conditional logistic regression. In addition, the Student's t-test was used to compare the mean alveolar bone height of the analysed groups. A p-value <0.05 was considered statistically significant. A total of 30 ultrasound examinations (12 cases and 18 controls) were analysed. A weak/absent mental artery pulse strength was significantly associated with edentulism (AOR = 3.67; 95% CI = 0.86-15.63; p = 0.046). In addition, there was a significant difference in alveolar bone height between edentulous cases and controls (p = 0.036). Within the limitations of this study, the present results indicate that edentulism is associated with diminished mental artery flow, which, in turn, affects alveolar bone height.

  4. Ultrasound analysis of mental artery flow in elderly patients: a case–control study

    Science.gov (United States)

    Baladi, Marina G; Tucunduva Neto, Raul R C M; Aoki, Eduardo M; Arita, Emiko S; Freitas, Claudio F

    2015-01-01

    Objectives: Mental artery flow decreases with age and may have an aetiological role in alveolar ridge atrophy. The aim of this study was to identify factors associated with alterations of mental artery flow, assessed by ultrasonography. Methods: This case–control study was conducted on elderly patients (aged above 60 years) at the beginning of dental treatment. Intraoral B-mode Doppler ultrasonography was used to assess mental artery flow. The cases were defined as patients with a weak/absent ultrasound signal, whereas the controls presented a strong ultrasound signal. Demographics and radiographic findings (low bone mineral density on dual-energy X-ray absorptiometry and mandibular cortical index on panoramic radiographs) were analysed as risk factors for weak/absent ultrasound signal and were calculated as adjusted odds ratios (AORs) with 95% confidence intervals (CIs) using conditional logistic regression. In addition, the Student's t-test was used to compare the mean alveolar bone height of the analysed groups. A p-value <0.05 was considered statistically significant. Results: A total of 30 ultrasound examinations (12 cases and 18 controls) were analysed. A weak/absent mental artery pulse strength was significantly associated with edentulism (AOR = 3.67; 95% CI = 0.86–15.63; p = 0.046). In addition, there was a significant difference in alveolar bone height between edentulous cases and controls (p = 0.036). Conclusions: Within the limitations of this study, the present results indicate that edentulism is associated with diminished mental artery flow, which, in turn, affects alveolar bone height. PMID:26205777

  5. [Influence of Sympathetic Denervation of the Renal Artery on the Level of Arterial Blood Pressure, Cerebral Blood Flow and Cognitive Function In Patients With Resistant Arterial Hypertension].

    Science.gov (United States)

    Efimova, Y N; Lichikaki, A V; Lishmanov, B Y

    2017-07-01

    To study the effect of radiofrequency ablation of renal arteries on regional cerebral blood flow and cognitive function in patients with resistant arterial hypertension (AH). Transcatheter renal denervation (TRD) was performed in 17 patients with resistant AH. Examination before and after TRD included SPECT with mTc-HMPAO, 24-hours blood pressure (BP) monitoring, and comprehensive neuropsychological testing. Fifteen patients without angiographic signs of carotid atherosclerosis, coronary artery disease and AH, neurological and psychiatric disorders were investigated as control group. Compared with control group patients with AH had decreases of regional cerebral blood flow (rCBF) in right (by 13.5%, p=0.00002) and left (by 15.5%, p=0.0006) inferior frontal lobes, in right temporal brain region (by 11.5%, p=0.008); in right and left occipital lobes (by 8.2%, p=0.04). In 6 months after TRD we observed significant improvement of cognitive function, parameters of 24-hour BP monitoring, and rCBF. We also noted definite close interdependence between changes of rCBF, indices of 24-hours BP monitoring, and dynamics of cognitive function. Improvement of long-term verbal memory correlated with increases of rCBF in left superior frontal and right occipital regions while dynamics of mentation and attention correlated positively with augmentation of rCBF in right posterior parietal region. Changes of perfusion in inferior parts of left frontal lobe and in right occipital region correlated with dynamics of index of diurnal diastolic hypertension time (R2=0.64, p=0.001, and R2=0.60, p=0.03, respectively). Our results suggest, that in patients with resistant AH positive effect of TRD on levels of 24-hour mean BP as well as on indices of BP load leads to in augmentation of rCBF and improvement of cognitive function.

  6. Surgical rationalization of living donor liver transplantation by abolition of hepatic artery reconstruction under a fixed microscope.

    Science.gov (United States)

    Yagi, Takahito; Shinoura, Susumu; Umeda, Yuzo; Sato, Daisuke; Yoshida, Ryuichi; Yoshida, Kazuhiro; Utsumi, Masashi; Nobuoka, Daisuke; Sadamori, Hiroshi; Fujiwara, Toshiyoshi

    2012-01-01

    The small diameter of the hepatic artery is one of the complexities of living donor liver transplantation (LDLT). We analyzed whether the direct suture technique using surgical loupes can simplify the operative process for LDLT compared with fixed microscopic reconstruction. We applied the direct technique to rationalize the operative process and abolished routine microsurgery from 2004. Two hundred and nine LDLT with a postoperative period over 34 months were carried out from 1996 to 2008. The patients were divided into two groups: the micro group (children: 20, adults: 72) and the non-micro group (children: 12, adults: 97). Running anastomosis was undertaken in the non-micro group. The anastomotic size of the children was significantly smaller than that of the adults, but larger than 2 mm (2.38±0.4 vs. 2.7±0.47 mm, p=0.0005). By appropriate choice of the proximal artery, direct anastomosis is possible even in children. Early complications occurred in seven cases in the micro group, but none occurred in the non-micro group (prationalization of LDLT. © 2012 John Wiley & Sons A/S.

  7. [THE STATE OF HEPATIC AND SPLANCHNIC BLOOD FLOW IN VARIOUS TYPES OF COMPLICATED PANCREATIC PSEUDOCYSTS].

    Science.gov (United States)

    Kryvoruchko, I A; Goncharova, N M; Andreyeshchev, S A; Yavorska, T P

    2015-05-01

    Investigations were conducted in 37 patients, suffering complicated pancreatic pseudocysts. In accordance to data of ultrasound Doppler flowmetry for the blood flow along portal vein, a. hepatis communis, a. mesenterica superior in complicated pancreatic pseudocysts compensatory--adaptive reactions on level of hepatic--spanchnic blood flow are directed towards restriction of the blood inflow through the portal vein system. This is accompanied by the common peripheral vascular resistence raising in basin of a. mesenterica superior, which have depended upon the patients' state severity, caused by reduction of the volume blood flow in a certan vascular collector. The oxygen debt of the liver in these patients is compensated by the volume blood flow enhancement along a. hepatis communis.

  8. Magnetization Transfer Effects on the Efficiency of Flow-driven Adiabatic Fast Passage Inversion of Arterial Blood

    OpenAIRE

    Hernandez-Garcia, Luis; Lewis, David P.; Moffat, Bradford; Branch, Craig A.

    2007-01-01

    Continuous arterial spin labeling experiments typically use flow-driven adiabatic fast passage (AFP) inversion of the arterial blood water protons. In this article, we measure the effect of magnetization transfer in blood and how it affects the inversion label. We use modified Bloch equations to model flow-driven adiabatic inversion in the presence of magnetization transfer in blood flowing at velocities from 1 to 30 cm/s in order to explain our findings. Magnetization transfer results in a r...

  9. Multidetector computed tomography for preoperative assessment of hepatic vasculature and prediction of splenic artery steal syndrome in patients with liver cirrhosis before transplantation

    International Nuclear Information System (INIS)

    Grieser, Christian; Denecke, Timm; Steffen, Ingo G.; Avgenaki, Maria; Froehling, Vera; Schnapauff, Dirk; Lehmkuhl, Lukas; Stelter, Lars; Streitparth, Florian; Rothe, Jan-Holger; Hamm, Bernd; Haenninen, Enrique Lopez; Mogl, Martina; Langrehr, Jan

    2010-01-01

    The purpose of this study was to evaluate the accuracy of MDCT for preoperative assessment of hepatic vascular anatomy and the identification of liver-transplantation (OLT) patients at risk of developing subsequent splenic artery steal syndrome (SASS). A total of 145 patients with liver cirrhosis who had undergone OLT and had pre-operative three-phase MDCT (4- to 64-rows) within 100 days before OLT were enrolled retrospectively. MDCT and 3Ds were reviewed by two independent blinded observers (O1/O2). Pre-operative imaging findings were correlated with intra-operative results; findings indicative for SASS were correlated with clinical data and DSA. Among all 145 patients, 16 patients (11%) showed accessory hepatic arteries (accuracy O1/O2, 97%; with 3Ds, 100%); 32 (22%) patients had replaced hepatic arteries (accuracy O1, 97%; O2, 95%; with 3Ds, 100%; κ=0.87 and 0.89, P<0.001). Among 119 patients, 12 patients developed SASS after OLT. The logistic regression model revealed the spleen volume (P=0.0105) as a predictive factor of SASS. With spleen volumes ≥829 ml, an accuracy of 75% for prediction of SASS was obtained. MDCT with three-dimensional post-processing (3Ds) was highly accurate for pre-operative hepatic vessel evaluation in patients before OLT. In addition, spleen volume was a predictive factor for developing SASS after OLT. (orig.)

  10. Successful flow reduction surgery for a ruptured true posterior communicating artery aneurysm caused by the common carotid artery ligation for epistaxis.

    Science.gov (United States)

    Yamao, Yukihiro; Takahashi, Jun C; Satow, Tetsu; Iihara, Koji; Miyamoto, Susumu

    2014-01-01

    Carotid artery occlusion can lead to the development of rare true posterior communicating artery (PCoA) aneurysms because of hemodynamic stress on the PCoA. Surgical treatment of these lesions is challenging. The authors report a case of a true PCoA aneurysm that developed and ruptured 37 years after ligation of the ipsilateral common carotid artery for epistaxis. The lesion was successfully treated with clipping of the distal M1 segment of the middle cerebral artery (MCA) after the occipital artery-radial artery free graft-MCA bypass, which led to extreme reduction in collateral flow through the PCoA. A cortical branch, located just proximal to the obliteration site, functioned as a sufficient flow outlet. The aneurysm shrank, and the patient has been doing well without any symptoms for 5 years after surgery. M1 obliteration combined with high-flow extra-intracranial bypass might be a promising option for a true PCoA aneurysm, and therapeutic design that leaves a sufficient flow outlet on the M1 is mandatory to avoid unexpected occlusion of the M1 and its perforators.

  11. Computer aided approximation of flow rate through systemic-pulmonary arterial shunts (SPAS).

    Science.gov (United States)

    Vennemann, Peter; Montag, Michael; Peters, Franz; Merzkirch, Wolfgang

    2012-02-22

    The discrimination of flow rates through bronchial arteries that are affected by pathological SPAS today still happens solely qualitatively. A reproducible quantification of flow rates, however, would enable the comprehension of phenomena like the intensified shunt perfusion seen in cases of chronic inflammations or the characterization of SPAS that may cause cardiovascular problems. A computational program is developed, that allows the modeling of individual bronchial arteries on the basis of the information provided by angiography. Angiographic images are available from the standard clinical assessment of SPAS. The flow through continuous and geometrically measurable vessel segments and SPAS is given by the law of Hagen-Poiseuille. The discharge through healthy branches is calculated by means of allometric scaling laws. The simulation results are verified by flow experiments in artificial vessel networks made of glass and PE tubing. The experimental set-up mimics realistic, pulsating pressure and flow conditions. When applied to the artificial vessel networks, the model described herein provides results for the volumetric flow rate that differ from values measured in laboratory experiments by volumetric flow through individual SPAS fairly independently from his experience and without the need of measurements additional to the mandatory angiography.

  12. The effects of fenoldopam on coronary conduit blood flow after coronary artery bypass graft surgery.

    LENUS (Irish Health Repository)

    Halpenny, M

    2012-02-03

    OBJECTIVE: To quantify the effects of fenoldopam, 0.1 microg\\/kg\\/min, on left internal mammary artery (LIMA) and saphenous vein blood flow after coronary anastomosis. DESIGN: Prospective, randomized, double-blind, placebo-controlled trial. SETTING: University teaching hospital, single institution. PARTICIPANTS: Thirty-one American Society of Anesthesiologists III patients undergoing elective coronary revascularization. INTERVENTIONS: A perivascular ultrasonic flow probe (Linton Instrumentation, Norfolk, UK) was placed around the LIMA and saphenous vein graft after coronary anastomosis. MEASUREMENTS AND MAIN RESULTS: Immediately before and at 5-minute intervals for 15 minutes after starting the infusion, blood flow was measured in the LIMA and one saphenous vein graft using a transit time ultrasonic flow probe. Heart rate, blood pressure, and central venous pressure were documented at these time points. Administration of fenoldopam, 0.1 microg\\/kg\\/min, did not alter heart rate or blood pressure. A small, nonsignificant increase in LIMA blood flow occurred during the 15-minute study period (30 +\\/- 12 to 35 +\\/- 10 mL\\/min) in patients who received fenoldopam. No significant changes occurred in the placebo group. CONCLUSIONS: The findings indicate that fenoldopam, 0.1 microg\\/kg\\/min, did not influence coronary conduit blood flow to a clinically significant extent. The small increase in LIMA blood flow may be of greater importance in high-risk patients or in the prevention of coronary arterial spasm.

  13. Demonstration of blood flow by color doppler in the femoral artery distal to arterial cannula during peripheral venoarterial-extracorporeal membrane oxygenation

    Directory of Open Access Journals (Sweden)

    K G Suresh Rao

    2017-01-01

    Full Text Available In spite of distal perfusion of the limb using a cannula, the limb can have ischemic events if there is an undetected kink or clot anywhere in the line or thrombus in the artery. There are several ways to monitor and assess the limb ischemia. Monitoring for clinical signs of limb ischemia like temperature change and pallor is reliable and mandatory. We report a method where we used color Doppler to document the blood flow. Curvilinear vascular probe of an echo machine is used to identify the flow in the distal femoral artery of the lower limb. . As we have demonstrated in the video attached, once flow to the distal limb perfusion system is shut off by closing the three way stop cock, we can appreciate the immediate cessation of flow in the artery by Doppler.

  14. MRI-based flow measurements in the main pulmonary artery to detect pulmonary arterial hypertension in patients with cystic fibrosis

    International Nuclear Information System (INIS)

    Wolf, T.; Anjorin, A.; Abolmaali, N.; Posselt, H.; Smaczny, C.; Vogl, T.J.

    2009-01-01

    Development of pulmonary arterial hypertension (PH) is a common problem in the course of patients suffering from cystic fibrosis (CF). This study was performed to evaluate MRI based flow measurements (MR venc ; Velocity ENCoding) to detect signs of an evolving PH in patients suffering from CF. 48 patients (median age: 16 years, range: 10 - 40 years, 25 female) suffering from CF of different severity (mean FEV1: 74 % ± 23, mean Shwachman-score: 63 ± 10) were examined using MRI based flow measurements of the main pulmonary artery (MPA). Phase-contrast flash sequences (TR: 9.6 ms, TE: 2.5 ms, bandwidth: 1395 Hertz/Pixel) were utilized. Results were compared to an age- and sex-matched group of 48 healthy subjects. Analyzed flow data where: heart frequency (HF), cardiac output (HZV), acceleration time (AT), proportional acceleration time related to heart rate (ATr), mean systolic blood velocity (MFG), peak velocity (Peak), maximum flow (Fluss max ), mean flow (Fluss mitt ) and distensibility (Dist). The comparison of means revealed significant differences only for MFG, Fluss max and Dist, but overlap was marked. However, using a scatter-plot of AT versus MFG, it was possible to identify five CF-patients demonstrating definite signs of PH: AT = 81 ms ± 14, MFG = 46 ± 11 cm/s, Dist = 41 % ± 7. These CF-patients where the most severely affected in the investigated group, two of them were listed for complete heart and lung transplantation. The comparison of this subgroup and the remaining CF-patients revealed a highly significant difference for the AT (p = 0.000001) without overlap. Screening of CF-patients for the development of PH using MR venc of the MPA is not possible. In later stages of disease, the quantification of AT, MFG and Dist in the MPA may be useful for the detection, follow-up and control of therapy of PH. MR venc of the MPA completes the MRI-based follow-up of lung parenchyma damage in patients suffering from CF. (orig.)

  15. Accurate evaluation of viscoelasticity of radial artery wall during flow-mediated dilation in ultrasound measurement

    Science.gov (United States)

    Sakai, Yasumasa; Taki, Hirofumi; Kanai, Hiroshi

    2016-07-01

    In our previous study, the viscoelasticity of the radial artery wall was estimated to diagnose endothelial dysfunction using a high-frequency (22 MHz) ultrasound device. In the present study, we employed a commercial ultrasound device (7.5 MHz) and estimated the viscoelasticity using arterial pressure and diameter, both of which were measured at the same position. In a phantom experiment, the proposed method successfully estimated the elasticity and viscosity of the phantom with errors of 1.8 and 30.3%, respectively. In an in vivo measurement, the transient change in the viscoelasticity was measured for three healthy subjects during flow-mediated dilation (FMD). The proposed method revealed the softening of the arterial wall originating from the FMD reaction within 100 s after avascularization. These results indicate the high performance of the proposed method in evaluating vascular endothelial function just after avascularization, where the function is difficult to be estimated by a conventional FMD measurement.

  16. Experimental research on treating hepatic carcinoma by arterial injection of liposome mediated p53 genes

    Energy Technology Data Exchange (ETDEWEB)

    Guangyu, Zhu; Qin, Lu; Gaojun, Teng; Jinhe, Guo; Hui, Yu; Gang, Deng; Shicheng, He; Wen, Fang; Guozhao, Li; Xiaoying, Wei [Zhongda Hospital, Southeast Univ., Nanjing (China)

    2007-02-15

    Objective: To investigate the transfection and expression of p53 genes mediated by liposome and its feasibility in treatment of liver cancer by transcatheter arterial injection on rabbit VX2 hepatocarcinoma model. Methods: pCMV-myc-p53 plasmids, LipofectAMINE and p53-LipofectAMINE complex were infused into tumor's feeding artery of rabbit VX2 hepatocarcinoma model, respectively, and then protein of cancer tissue was extracted, followed by measuring gene transfection and expression by western blot and immunohistochemistry, p53-LipofectAMlNE complex in different doses were infused into tumor's feeding artery of rabbit VX2 hepatocarcinoma model with the gene transfection and expression detected by the same way. Results: Liposome-mediated p53 gene injected through catheter could be successfully transfected and expressed in the cancer tissue of rabbit VX2 hepatocarcinoma model, with transfection efficiency higher than the gene delivery alone. The efficiency and the gene dose has dose-effect relationship. Conclusions: Treatment of liver cancer by transcatheter arterial injection of p53 genes mediated by liposome is a feasible and effective method, with wide prospect of application. (authors)

  17. Experimental research on treating hepatic carcinoma by arterial injection of liposome mediated p53 genes

    International Nuclear Information System (INIS)

    Zhu Guangyu; Lu Qin; Teng Gaojun; Guo Jinhe; Yu Hui; Deng Gang; He Shicheng; Fang Wen; Li Guozhao; Wei Xiaoying

    2007-01-01

    Objective: To investigate the transfection and expression of p53 genes mediated by liposome and its feasibility in treatment of liver cancer by transcatheter arterial injection on rabbit VX2 hepatocarcinoma model. Methods: pCMV-myc-p53 plasmids, LipofectAMINE and p53-LipofectAMINE complex were infused into tumor's feeding artery of rabbit VX2 hepatocarcinoma model, respectively, and then protein of cancer tissue was extracted, followed by measuring gene transfection and expression by western blot and immunohistochemistry, p53-LipofectAMlNE complex in different doses were infused into tumor's feeding artery of rabbit VX2 hepatocarcinoma model with the gene transfection and expression detected by the same way. Results: Liposome-mediated p53 gene injected through catheter could be successfully transfected and expressed in the cancer tissue of rabbit VX2 hepatocarcinoma model, with transfection efficiency higher than the gene delivery alone. The efficiency and the gene dose has dose-effect relationship. Conclusions: Treatment of liver cancer by transcatheter arterial injection of p53 genes mediated by liposome is a feasible and effective method, with wide prospect of application. (authors)

  18. Relationship between haemodynamic impairment and collateral blood flow in carotid artery disease.

    Science.gov (United States)

    Hartkamp, Nolan S; Petersen, Esben T; Chappell, Michael A; Okell, Thomas W; Uyttenboogaart, Maarten; Zeebregts, Clark J; Bokkers, Reinoud Ph

    2017-01-01

    Collateral blood flow plays a pivotal role in steno-occlusive internal carotid artery (ICA) disease to prevent irreversible ischaemic damage. Our aim was to investigate the effect of carotid artery disease upon cerebral perfusion and cerebrovascular reactivity and whether haemodynamic impairment is influenced at brain tissue level by the existence of primary and/or secondary collateral. Eighty-eight patients with steno-occlusive ICA disease and 29 healthy controls underwent MR examination. The presence of collaterals was determined with time-of-flight, two-dimensional phase contrast MRA and territorial arterial spin labeling (ASL) imaging. Cerebral blood flow and cerebrovascular reactivity were assessed with ASL before and after acetazolamide. Cerebral haemodynamics were normal in asymptomatic ICA stenosis patients, as opposed to patients with ICA occlusion, in whom the haemodynamics in both hemispheres were compromised. Haemodynamic impairment in the affected brain region was always present in symptomatic patients. The degree of collateral blood flow was inversely correlated with haemodynamic impairment. Recruitment of secondary collaterals only occurred in symptomatic ICA occlusion patients. In conclusion, both CBF and cerebrovascular reactivity were found to be reduced in symptomatic patients with steno-occlusive ICA disease. The presence of collateral flow is associated with further haemodynamic impairment. Recruitment of secondary collaterals is associated with severe haemodynamic impairment.

  19. An Outflow Boundary Condition Model for Noninvasive Prediction of Fractional Flow Reserve in Diseased Coronary Arteries.

    Science.gov (United States)

    Fayssal, Iyad A; Moukalled, Fadl; Alam, Samir; Isma'eel, Hussain

    2018-04-01

    This paper reports on a new boundary condition formulation to model the total coronary myocardial flow and resistance characteristics of the myocardial vascular bed for any specific patient when considered for noninvasive diagnosis of ischemia. The developed boundary condition model gives an implicit representation of the downstream truncated coronary bed. Further, it is based on incorporating patient-specific physiological parameters that can be noninvasively extracted to account for blood flow demand to the myocardium at rest and hyperemic conditions. The model is coupled to a steady three-dimensional (3D) collocated pressure-based finite volume flow solver and used to characterize the "functional significance" of a patient diseased coronary artery segment without the need for predicting the hemodynamics of the entire arterial system. Predictions generated with this boundary condition provide a deep understanding of the inherent challenges behind noninvasive image-based diagnostic techniques when applied to human diseased coronary arteries. The overall numerical method and formulated boundary condition model are validated via two computational-based procedures and benchmarked with available measured data. The newly developed boundary condition is used via a designed computational methodology to (a) confirm the need for incorporating patient-specific physiological parameters when modeling the downstream coronary resistance, (b) explain the discrepancies presented in the literature between measured and computed fractional flow reserve (FFRCT), and (c) discuss the current limitations and future challenges in shifting to noninvasive assessment of ischemia.

  20. Experimental investigations of the steady flow through an idealized model of a femoral artery bypass

    Directory of Open Access Journals (Sweden)

    Giurgea Corina

    2014-03-01

    Full Text Available The present paper presents the steps taken by the authors in the first stage of an experimental program within a larger national research project whose objective is to characterize the flow through a femoral artery bypass with a view to finding solutions for its optimization. The objective of the stage is to investigate by means of the PIV method the stationary flow through a bypass model with an idealized geometry. A bypass assembly which reunites the idealized geometry models of the proximal and distal anastomoses, and which respects the lengths of a femoral artery bypass was constructed on the basis of data for a real patient provided by medical investigations. With the aim of testing the model and the established experimental set-up with regard to their suitability for the assessment of the velocity field associated to the steady flow through the bypass, three zones that can restore the whole distal anastomosis were PIV investigated. The measurements were taken in the conditions of maintained inflow at the bypass entry of 0.9 l / min (Re = 600. The article presents comparatively the flow spectra and the velocity fields for each zone obtained in two situations: with the femoral artery completely occluded and completely open.

  1. Effect of contrast-enhanced ultrasound on differential diagnosis of intrahepatic cholangiocarcinoma and arterial phase enhanced hepatic inflammatory lesions

    Institute of Scientific and Technical Information of China (English)

    Shanshan Yin; Qiuli Cui; Kun Yan; Wei Yang; Wei Wu; Liping Bao; Minhua Chen

    2017-01-01

    Objective:To investigate differential diagnosis between intrahepatic cholangiocarcinoma (ICC) and arterial phase enhanced hepatic inflammatory lesions in patients without liver cirrhosis using contrast-enhanced ultrasound (CEUS).Methods:ICC and hepatic inflammatory lesions cases with CEUS and pathological diagnosis between Sep 2013 and Oct 2016 were investigated retrospectively.Imaging features of conventional ultrasound and CEUS were analyzed.The parameters of time intensity curve (TIC),including the arrival time,peak intensity (PI) in the lesions,the starting time for washout,and the intensity difference at 3 min (△I3) after contrast agent infection between the lesion and the liver parenchyma,were compared between ICC and hepatic inflammatory lesions.Results:Twenty-five ICC and fifteen inflammatory patients were included in this study.Seventeen ICC (68.0%) and two inflammatory cases (13.3%) showed bile duct dilatation on conventional ultrasound.Using CEUS,three ICC cases (12.0%) were misdiagnosed as inflammatory lesions and three inflammatory lesions (20.0%) as ICC;two ICC (8.0%) and one inflammatory case (6.7%) could not be made definite diagnosis.Washout started at 34.5±3.5 s and 61.5± 12.9 s for ICC and inflammatory lesions respectively (P<0.001).The intensity difference between lesion and liver parenchyma at 3 min after contrast agent injection was 10.8±3.1 dB in ICC and 4.2±2.3 dB in inflammatory group (P<0.00 1).The sensitivity and specificity differentiating ICC and inflammatory lesions were 76% and 87% if the cut-offvalue of the intensity difference was 7.7 dB.Conclusions:Combined with TIC analysis,and particularly with the characteristic of the early-starting and obvious washout in ICC,CEUS can be useful in differential diagnosis between hepatic inflammatory lesions and ICC.

  2. The relationship of flow velocities to vessel diameters differs between extracranial carotid and vertebral arteries of stroke patients.

    Science.gov (United States)

    Owolabi, Mayowa O; Agunloye, Atinuke M; Ogunniyi, Adesola

    2014-01-01

    Chronic changes in flow rate through arteries produce adjustment of arterial diameters. We compared the relationship between flow velocity and diameter in the carotid and in the vertebral arteries of stroke patients. Using triplex ultrasonography, the internal diameter and flow velocities of the common carotid, internal carotid, and vertebral arteries of 176 consecutive stroke patients were measured. Correlations were examined with Pearson's statistics at an alpha level of 0.05. Mean age of the patients was 59.3 ± 12 years, and 66% had cerebral infarcts. Diameter and blood flow velocities showed significant negative correlations (-0.115 ≥ r ≥ -0.382) in the carotid arteries on both sides, but positive correlations (0.211 ≤ r ≤ 0.320) in the vertebral arteries, even after controlling for age, gender, and blood pressure. Our study demonstrated different diameter/flow relationships in the carotid and the vertebral arteries of stroke patients, which may suggest pathologic changes in the adaptive processes governing vessel diameter and growth, especially in the carotid arteries. Copyright © 2013 Wiley Periodicals, Inc.

  3. Status of systemic to pulmonary arterial collateral flow after the fontan procedure.

    Science.gov (United States)

    Whitehead, Kevin K; Harris, Matthew A; Glatz, Andrew C; Gillespie, Matthew J; DiMaria, Michael V; Harrison, Neil E; Dori, Yoav; Keller, Marc S; Rome, Jonathan J; Fogel, Mark A

    2015-06-15

    The investigators recently validated a method of quantifying systemic-to-pulmonary arterial collateral flow using phase-contrast magnetic resonance imaging velocity mapping. Cross-sectional data suggest decreased collateral flow in patients with total cavopulmonary connections (TCPCs) compared with those with superior cavopulmonary connections (SCPCs). However, no studies have examined serial changes in collateral flow from SCPCs to TCPCs in the same patients. The aim of this study was to examine differences in collateral flow between patients with SCPCs and those with TCPCs. Collateral flow was quantified by 2 independent measures from 250 single-ventricle studies in 219 different patients (115 SCPC and 135 TCPC studies, 31 patients with both) and 18 controls, during routine studies using through-plane phase-contrast magnetic resonance imaging. Collateral flow was indexed to body surface area, aortic flow, and pulmonary venous flow. Regardless of indexing method, SCPC patients had significantly higher collateral flow than TCPC patients (1.64 ± 0.8 vs 1.03 ± 0.8 L/min/m(2), p <0.001). In 31 patients who underwent serial examinations, collateral flow as a fraction of aortic flow increased early after TCPC completion. In TCPC patients, indexed collateral flow demonstrated a significant negative correlation with time from TCPC. In conclusion, SCPC and TCPC patients demonstrate substantial collateral flow, with SCPC patients having higher collateral flow than TCPC patients overall. On the basis of the paired subset analysis, collateral flow does not decrease in the short term after TCPC completion and trends toward an increase. In the long term, however, collateral flow decreases over time after TCPC completion. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Regional cerebral blood flow during mechanical hyperventilation in patients with fulminant hepatic failure

    DEFF Research Database (Denmark)

    Strauss, Gitte Irene; Høgh, Peter; Møller, Kirsten

    1999-01-01

    Hyperventilation is frequently used to prevent or postpone the development of cerebral edema and intracranial hypertension in patients with fulminant hepatic failure (FHF). The influence of such therapy on regional cerebral blood flow (rCBF) remains, however, unknown. In this study the CBF......-distribution pattern was determined within the first 12 hours after development of hepatic encephalopathy (HE) stage 4 before and during hyperventilation. Ten consecutive patients (median age 48 [range 33-57] years) with FHF and 9 healthy controls (median age 54 [24-58] years) had rCBF determined by single photon...... emission computed tomography (SPECT) using intravenous injection of 133Xenon. For determination of high resolution CBF pattern, the patients were also studied with 99mTc-hexa-methylpropyleneamine oxime (HMPAO) in the hyperventilation condition. There was no significant difference in the rCBF distribution...

  5. Transcatheter arterial embolization with trisacryl gelatin microspheres (Embosphere®) leads to life-threatening tumor lysis syndrome in a rectal carcinoid patient with hepatic metastases

    International Nuclear Information System (INIS)

    Lo, Yuan-Hao; Tsai, Ming-Tsun; Kuo, Chen-Yu; Liu, Wen-Sheng; Lee, Rheun-Chuan; Yeh, Yi-Chen; Li, Chung-Pin; Chen, Jinn-Yang; Chao, Yee

    2012-01-01

    The incidence of gastrointestinal carcinoids appears to be increasing, and the rectum is the third most common location. Transcatheter arterial embolization (TAE) with trisacryl gelatin microspheres (Embosphere ® ) has been reported as an effective method for hepatic metastases of rectal carcinoids. Complications are uncommon and usually of minor consequence. We report an unusual case of a 34-year-old man with tumor lysis syndrome following TAE with Embosphere ® in a patient with multiple hepatic metastases of a rectal carcinoid. Early detection and effective treatment are essential for this rare but potentially catastrophic complication

  6. A Study Demonstrating the Quantitative Relationship Between Internal Thoracic Artery Length and Free Flow.

    Science.gov (United States)

    Gode, Safa; Sen, Onur; Kadirogulları, Ersin; Reyhancan, Adem; Kyaruzi, Mugisha; Satılmısoglu, Muhammet Hulusi; Erkanlı, Korhan

    2017-08-09

    The left internal thoracic artery (LITA) is the most commonly used arterial bypass conduit in coronary artery bypass graft (CABG) patients and inadequate LITA flow can result in an increase in morbidity and mortality. In this study, we evaluated the effect of excision of the distal spasmodic segment of the LITA on the free flow in CABG patients. This study consisted of 47 patients who underwent elective CABG performed with or without other cardiac surgery, between July 2015 and December 2015. Excised LITA length was shorter than 15mm in group 1, between 15mm and 30mm in group 2 and longer than 30mm in group 3. Left ITA free flow was measured for 60seconds into a container before and after the distal LITA excision. The inter-measurement differences were calculated for the three groups. Thereafter, the comparison was performed in terms of free flow difference amongst the three groups. The mean difference of LITA free flow was 27.6±22.7ml/minute in group 1, 35.4±26.7ml/minute in group 2, and 52.6±26.1ml/minute in group 3. There were significant differences in terms of free flow difference between the groups (p=0.008). Also, differences were statistically significant in group 1 versus group 3 (p=0.003) and group 2 versus group 3 (p=0.038) in the intergroup comparisons. The distal part of the LITA has more spasmodic potential than other segments. This spasm may result in low flow of LITA grafts. Therefore, an as long as possible excision of the distal LITA segment may be required to avoid the spasmodic effect. Copyright © 2017 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  7. Angiohepatogram in diffuse hepatic disease

    Energy Technology Data Exchange (ETDEWEB)

    Aburano, T; Suzuki, Y; Hisada, K [Kanazawa Univ. (Japan). School of Medicine; Matsudaira, M

    1975-10-01

    A region of interest angiohepatogram was obtained with intravenous injection of 10mCi of sup(99m)Tc-Sn-colloid and a data processing system. Furthermore, the ratio of hepatic arterial blood flow volume to total hepatic blood flow volume was calculated according to Ueda's method, and the correlation of this calculated ratio and the degree of extrahepatic distribution of sup(99m)Tc-Sn-colloid (spleen to liver, and bone marrow to liver activity ratio) was examined. Most cases of liver cirrhosis and Banti's syndrome showed the increased hepatic arterial blood flow ratio (liver cirrhosis: 43.5+-9.5%, Banti's syndrome 48.8+-4.9%) in contrast with 18.1+-4.6% in normal cases, and its ratio showed much higher values in the presence of portal hypertension manifestations (esophageal varix and ascites). The hepatic arterial blood flow ratio showed increased values in the case of markedly increased extrahepatic activity, e.g. liver cirrhosis, and the correlation of the ratio and extrahepatic activity degree of sup(99m)Tc-Sn-colloid was significant statistically. From these results, a region of interest angiohepatogram was supposed to be useful for the prediction of the hemodynamic change, as well as, the improvement of diagnostic accuracy with radioisotope in diffuse hepatic disease, especially liver cirrhosis. Moreover, the hemodynamic change of liver, especially the reduction of the effectivehepatic blood flow volume via the portal vein was considered to be closely concerned in the mechanism of increased extrahepatic activity of RI colloid in diffuse hepatic disease.

  8. Patient Specific Multiscale Simulations of Blood Flow in Coronary Artery Bypass Surgery

    Science.gov (United States)

    Bangalore Ramachandra, Abhay; Sankaran, Sethuraman; Kahn, Andrew M.; Marsden, Alison L.

    2013-11-01

    Coronary artery bypass surgery is performed to revascularize blocked coronary arteries in roughly 400,000 patients per year in the US.While arterial grafts offer superior patency, vein grafts are used in more than 70% of procedures, as most patients require multiple grafts. Vein graft failure (approx. 50% within 10 years) remains a major clinical issue. Mounting evidence suggests that hemodynamics plays a key role as a mechano-biological stimulus contributing to graft failure. However, quantifying relevant hemodynamic quantities (e.g. wall shear stress) invivo is not possible directly using clinical imaging techniques. We numerically compute graft hemodynamics in a cohort of 3-D patient specific models using a stabilized finite element method. The 3D flow domain is coupled to a 0D lumped parameter circulatory model. Boundary conditions are tuned to match patient specific blood pressures, stroke volumes & heart rates. Results reproduce clinically observed coronary flow waveforms. We quantify differences in multiple hemodynamic quantities between arterial & venous grafts & discuss possible correlations between graft hemodynamics & clinically observed graft failure.Such correlations will provide further insight into mechanisms of graft failure and may lead to improved clinical outcomes.

  9. Sequential hepato-splenic scintigraphy for measurement of hepatic blood flow

    International Nuclear Information System (INIS)

    Biersack, H.J.; Knopp, R.; Dahlem, R.; Winkler, C.; Thelen, M.; Schulz, D.; Schmidt, R.

    1977-01-01

    The arterial and portal components of total liver blood flow were determined quantitatively in 31 patients by means of a new, non-invasive method. Sequential hepato-splenic scintigraphy has been employed, using a scintillation camera linked to a computer system. In normals, the proportion of portal flow was 71%, whereas in patients with portal hypertension it averaged 21%. Our experience indicates that the procedure can be of considerable value in the pre-operative diagnosis and postoperative follow-up of portal hypertension. (orig.) [de

  10. Sequential hepato-splenic scintigraphy for measurement of hepatic blood flow

    Energy Technology Data Exchange (ETDEWEB)

    Biersack, H J; Knopp, R; Dahlem, R; Winkler, C [Bonn Univ. (Germany, F.R.). Inst. fuer Klinische und Experimentelle Nuklearmedizin; Thelen, M [Bonn Univ. (Germany, F.R.). Radiologische Klinik; Schulz, D; Schmidt, R [Bonn Univ. (Germany, F.R.). Chirurgische Klinik und Poliklinik

    1977-01-01

    The arterial and portal components of total liver blood flow were determined quantitatively in 31 patients by means of a new, non-invasive method. Sequential hepato-splenic scintigraphy has been employed, using a scintillation camera linked to a computer system. In normals, the proportion of portal flow was 71%, whereas in patients with portal hypertension it averaged 21%. Our experience indicates that the procedure can be of considerable value in the pre-operative diagnosis and postoperative follow-up of portal hypertension.

  11. Diastolic coronary artery pressure-flow velocity relationships in conscious man.

    Science.gov (United States)

    Dole, W P; Richards, K L; Hartley, C J; Alexander, G M; Campbell, A B; Bishop, V S

    1984-09-01

    We characterised the diastolic pressure-flow velocity relationship in the normal left coronary artery of conscious man before and after vasodilatation with angiographic contrast medium. Phasic coronary artery pressure and flow velocity were measured in ten patients during individual diastoles (0.5 to 1.0 s) using a 20 MHz catheter-tipped, pulsed Doppler transducer. All pressure-flow velocity curves were linear over the diastolic pressure range of 110 +/- 15 (SD) mmHg to 71 +/- 7 mmHg (r = 0.97 +/- 0.01). In the basal state, values for slope and extrapolated zero flow pressure intercept averaged 0.35 +/- 0.12 cm X s-1 X mmHg-1 and 51.7 +/- 8.6 mmHg, respectively. Vasodilatation resulted in a 2.5 +/- 0.5 fold increase in mean flow velocity. The diastolic pressure-flow velocity relationship obtained during peak vasodilatation compared to that during basal conditions was characterised by a steeper slope (0.80 +/- 0.48 cm X s-1 X mmHg-1, p less than 0.001) and lower extrapolated zero flow pressure intercept (37.9 +/- 9.8 mmHg, p less than 0.05). Mean right atrial pressure for the group averaged 4.4 +/- 1.7 mmHg, while left ventricular end-diastolic pressure averaged 8.7 +/- 2.8 mmHg. These observations in man are similar to data reported in the canine coronary circulation which are consistent with a vascular waterfall model of diastolic flow regulation. In this model, coronary blood flow may be regulated by changes in diastolic zero flow pressure as well as in coronary resistance.

  12. Cerebral blood flow response to changes in arterial carbon dioxide tension during hypothermic cardiopulmonary bypass in children

    International Nuclear Information System (INIS)

    Kern, F.H.; Ungerleider, R.M.; Quill, T.J.; Baldwin, B.; White, W.D.; Reves, J.G.; Greeley, W.J.

    1991-01-01

    We examined the relationship of changes in partial pressure of carbon dioxide on cerebral blood flow responsiveness in 20 pediatric patients undergoing hypothermic cardiopulmonary bypass. Cerebral blood flow was measured during steady-state hypothermic cardiopulmonary bypass with the use of xenon 133 clearance methodology at two different arterial carbon dioxide tensions. During these measurements there was no significant change in mean arterial pressure, nasopharyngeal temperature, pump flow rate, or hematocrit value. Cerebral blood flow was found to be significantly greater at higher arterial carbon dioxide tensions (p less than 0.01), so that for every millimeter of mercury rise in arterial carbon dioxide tension there was a 1.2 ml.100 gm-1.min-1 increase in cerebral blood flow. Two factors, deep hypothermia (18 degrees to 22 degrees C) and reduced age (less than 1 year), diminished the effect carbon dioxide had on cerebral blood flow responsiveness but did not eliminate it. We conclude that cerebral blood flow remains responsive to changes in arterial carbon dioxide tension during hypothermic cardiopulmonary bypass in infants and children; that is, increasing arterial carbon dioxide tension will independently increase cerebral blood flow

  13. Comparison of fractional flow reserve of composite Y-grafts with saphenous vein or right internal thoracic arteries.

    Science.gov (United States)

    Glineur, David; Boodhwani, Munir; Poncelet, Alain; De Kerchove, Laurent; Etienne, Pierre Yves; Noirhomme, Philippe; Deceuninck, Paul; Michel, Xavier; El Khoury, Gebrine; Hanet, Claude

    2010-09-01

    Composite Y-grafts, using the left internal thoracic artery as the inflow, allow a more efficient use of conduits without the need to touch a diseased ascending aorta. Among other conduits, the saphenous vein graft may be an alternative to the radial artery in elderly patients. We evaluated the hemodynamic characteristics of 17 composite Y-grafts made with the left internal thoracic artery anastomosed to the left anterior descending coronary artery in all cases and with either the free right internal thoracic artery (RITA group, n = 10) or a saphenous vein graft (SVG group, n = 7) implanted proximally to the left internal thoracic artery and distally to the circumflex territory 6 months after the operation. At baseline, the pressure gradient measured with a 0.014-inch pressure wire was minimal between the aorta and the internal thoracic artery stem (2 +/- 1 mm Hg), the internal thoracic artery and left anterior descending (4 +/- 2 mm Hg), the internal thoracic artery and left circumflex (3 +/- 1 mm Hg), and the saphenous vein graft and left circumflex (2 +/- 2 mm Hg). During hyperemia induced by adenosine, the pressure gradient increased significantly to 6 +/- 2 mm Hg in the internal thoracic artery stem, 9 +/- 4 mm Hg in the internal thoracic artery and left anterior descending artery, 9 +/- 3 mm Hg in the internal thoracic artery and left circumflex, and 7 +/- 4 mm Hg in the saphenous vein graft and left circumflex. Fractional flow reserve was 0.94 +/- 0.02 in internal thoracic artery stem, 0.90 +/- 0.04 mm Hg in the internal thoracic artery and left anterior descending, 0.91 +/- 0.03 mm Hg in the internal thoracic artery and left circumflex, and 0.92 +/- 0.06 mm Hg in the saphenous vein graft and left circumflex. No difference between the two types of composite Y-grafts was observed for pressure gradients or fractional flow reserve measured in internal thoracic artery stem or in distal branches. Composite Y-grafts with saphenous vein or right internal thoracic

  14. The Blood Disappearance Rate of 1{sup 98A}u-Colloid and Changes of Hepatic Blood Flow During Position Change in Normal Persons and in Patients with Various Hepatic Diseases

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Bo Yeon [Capital Armed Force General Hospital, Seoul (Korea, Republic of); Hong, Kee Suk; Koh, Chang Soon; Lee, Mun Ho [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1977-03-15

    To evaluate the diagnostic significance of the blood disappearance rate of {sup 198}Au-colloid and to evaluate the change of hepatic blood flow during position change from supine to erect, we measured the half time of blood disappearance rate of {sup 198}Au-colloid using external counting method in 94 normal persons and in 77 patients with various hepatic diseases. The results obtained were as follows: 1) In normal control, the mean blood disappearance half time of {sup 198}Au-colloid in supine position was 2.7+-0.4 minutes. There was no significant difference of hepatic blood flow in age and sex. 2) In acute hepatitis, chronic hepatitis and hepatic cirrhosis, the mean blood disappearance half times in supine position were 3.0+-0.45, 3.5+-0.74, 7.2+-3.6 minutes respectively. The hepatic blood flow of the patients with chronic hepatitis and hepatic cirrhosis were significantly decreased than that of normal control. 3) In the normal control and acute hepatitis, the decreases of the hepatic blood flow during the position change from supine to erect were 27.7% and 22.6% respectively.

  15. Relationship between haemodynamic impairment and collateral blood flow in carotid artery disease

    DEFF Research Database (Denmark)

    Hartkamp, Nolan S; Petersen, Esben T; Chappell, Michael A

    2018-01-01

    Collateral blood flow plays a pivotal role in steno-occlusive internal carotid artery (ICA) disease to prevent irreversible ischaemic damage. Our aim was to investigate the effect of carotid artery disease upon cerebral perfusion and cerebrovascular reactivity and whether haemodynamic impairment...... is influenced at brain tissue level by the existence of primary and/or secondary collateral. Eighty-eight patients with steno-occlusive ICA disease and 29 healthy controls underwent MR examination. The presence of collaterals was determined with time-of-flight, two-dimensional phase contrast MRA and territorial....... In conclusion, both CBF and cerebrovascular reactivity were found to be reduced in symptomatic patients with steno-occlusive ICA disease. The presence of collateral flow is associated with further haemodynamic impairment. Recruitment of secondary collaterals is associated with severe haemodynamic impairment....

  16. Evaluation of Coronary Artery Stenosis by Quantitative Flow Ratio During Invasive Coronary Angiography

    DEFF Research Database (Denmark)

    Westra, Jelmer; Tu, Shengxian; Winther, Simon

    2018-01-01

    BACKGROUND: Quantitative flow ratio (QFR) is a novel diagnostic modality for functional testing of coronary artery stenosis without the use of pressure wires and induction of hyperemia. QFR is based on computation of standard invasive coronary angiographic imaging. The purpose of WIFI II (Wire...... patients with suspected coronary artery disease on coronary computed tomographic angiography for diagnostic invasive coronary angiography. Fractional flow reserve (FFR) was measured in all segments with 30% to 90% diameter stenosis. Blinded observers calculated QFR (Medis Medical Imaging bv......, The Netherlands) for comparison with FFR. FFR was measured in 292 lesions from 191 patients. Ten (5%) and 9 patients (5%) were excluded because of FFR and angiographic core laboratory criteria, respectively. QFR was successfully computed in 240 out of 255 lesio