WorldWideScience

Sample records for heparin reduction algorithm

  1. Evidence-based algorithm for heparin dosing before cardiopulmonary bypass. Part 1: Development of the algorithm.

    Science.gov (United States)

    McKinney, Mark C; Riley, Jeffrey B

    2007-12-01

    The incidence of heparin resistance during adult cardiac surgery with cardiopulmonary bypass has been reported at 15%-20%. The consistent use of a clinical decision-making algorithm may increase the consistency of patient care and likely reduce the total required heparin dose and other problems associated with heparin dosing. After a directed survey of practicing perfusionists regarding treatment of heparin resistance and a literature search for high-level evidence regarding the diagnosis and treatment of heparin resistance, an evidence-based decision-making algorithm was constructed. The face validity of the algorithm decisive steps and logic was confirmed by a second survey of practicing perfusionists. The algorithm begins with review of the patient history to identify predictors for heparin resistance. The definition for heparin resistance contained in the algorithm is an activated clotting time 450 IU/kg heparin loading dose. Based on the literature, the treatment for heparin resistance used in the algorithm is anti-thrombin III supplement. The algorithm seems to be valid and is supported by high-level evidence and clinician opinion. The next step is a human randomized clinical trial to test the clinical procedure guideline algorithm vs. current standard clinical practice.

  2. Clinical effectiveness of a Bayesian algorithm for the diagnosis and management of heparin-induced thrombocytopenia.

    Science.gov (United States)

    Raschke, R A; Gallo, T; Curry, S C; Whiting, T; Padilla-Jones, A; Warkentin, T E; Puri, A

    2017-08-01

    Essentials We previously published a diagnostic algorithm for heparin-induced thrombocytopenia (HIT). In this study, we validated the algorithm in an independent large healthcare system. The accuracy was 98%, sensitivity 82% and specificity 99%. The algorithm has potential to improve accuracy and efficiency in the diagnosis of HIT. Background Heparin-induced thrombocytopenia (HIT) is a life-threatening drug reaction caused by antiplatelet factor 4/heparin (anti-PF4/H) antibodies. Commercial tests to detect these antibodies have suboptimal operating characteristics. We previously developed a diagnostic algorithm for HIT that incorporated 'four Ts' (4Ts) scoring and a stratified interpretation of an anti-PF4/H enzyme-linked immunosorbent assay (ELISA) and yielded a discriminant accuracy of 0.97 (95% confidence interval [CI], 0.93-1.00). Objectives The purpose of this study was to validate the algorithm in an independent patient population and quantitate effects that algorithm adherence could have on clinical care. Methods A retrospective cohort comprised patients who had undergone anti-PF4/H ELISA and serotonin release assay (SRA) testing in our healthcare system from 2010 to 2014. We determined the algorithm recommendation for each patient, compared recommendations with the clinical care received, and enumerated consequences of discrepancies. Operating characteristics were calculated for algorithm recommendations using SRA as the reference standard. Results Analysis was performed on 181 patients, 10 of whom were ruled in for HIT. The algorithm accurately stratified 98% of patients (95% CI, 95-99%), ruling out HIT in 158, ruling in HIT in 10 and recommending an SRA in 13 patients. Algorithm adherence would have obviated 165 SRAs and prevented 30 courses of unnecessary antithrombotic therapy for HIT. Diagnostic sensitivity was 0.82 (95% CI, 0.48-0.98), specificity 0.99 (95% CI, 0.97-1.00), PPV 0.90 (95% CI, 0.56-0.99) and NPV 0.99 (95% CI, 0.96-1.00). Conclusions An

  3. Unfractionated heparin versus low molecular weight heparins for avoiding heparin-induced thrombocytopenia in postoperative patients.

    Science.gov (United States)

    Junqueira, Daniela R; Zorzela, Liliane M; Perini, Edson

    2017-04-21

    the accepted definition of HIT. This was defined as a relative reduction in the platelet count of 50% or greater from the postoperative peak (even if the platelet count at its lowest remained greater than 150 x 10 9 /L) occurring within five to 14 days after the surgery, with or without a thrombotic event occurring in this timeframe. Additionally, we required circulating antibodies associated with the syndrome to have been investigated through laboratory assays. Two review authors independently extracted data and assessed the risk of bias. Disagreements were resolved by consensus with participation of a third author. In this update, we included three trials involving 1398 postoperative participants. Participants were submitted to general surgical procedures, minor and major, and the minimum mean age was 49 years. Pooled analysis showed a significant reduction in the risk of HIT with LMWH compared with UFH (risk ratio (RR) 0.23, 95% confidence interval (CI) 0.07 to 0.73); low-quality evidence. The number needed to treat for an additional beneficial outcome (NNTB) was 59. The risk of HIT was consistently reduced comparing participants undergoing major surgical procedures exposed to LMWH or UFH (RR 0.22, 95% CI 0.06 to 0.75); low-quality evidence. The occurrence of HIT complicated by venous thromboembolism was significantly lower in participants receiving LMWH compared with UFH (RR 0.22, 95% CI 0.06 to 0.84); low-quality evidence. The NNTB was 75. Arterial thrombosis occurred in only one participant who received UFH. There were no amputations or deaths documented. Although limited evidence is available, it appears that HIT induced by both types of heparins is common in people undergoing major surgical procedures (incidence greater than 1% and less than 10%). This updated review demonstrated low-quality evidence of a lower incidence of HIT, and HIT complicated by venous thromboembolism, in postoperative patients undergoing thromboprophylaxis with LMWH compared with UFH

  4. Heparin kinetics

    International Nuclear Information System (INIS)

    Swart, C.A.M. de.

    1983-01-01

    The author has studied the kinetics of heparin and heparin fractions after intravenous administration in humans and in this thesis the results of this study are reported. Basic knowledge about the physico-chemical properties of heparin and its interactions with proteins resulting in anticoagulant and lipolytic effects are discussed in a review (chapter II), which also comprises some clinical aspects of heparin therapy. In chapter III the kinetics of the anticoagulant effect are described after intravenous administration of five commercial heparin preparations. A mathematical model is presented that fits best to these kinetics. The kinetics of the anticoagulant and lipolytic effects after intravenous injection of various 35 S-radiolabelled heparin fractions and their relationship with the disappearance of the radiolabel are described in chapter IV. Chapter V gives a description of the kinetics of two radiolabels after injection of in vitro formed complexes consisting of purified, 125 I-radiolabelled antithrombin III and various 35 S-radiolabelled heparin fractions. (Auth.)

  5. Voltammetric determination of heparin based on its interaction with malachite green

    Directory of Open Access Journals (Sweden)

    Xueliang Niu

    2008-08-01

    Full Text Available In this paper malachite green (MG was used as a bioprobe to determine heparin concentration by linear sweep voltammetry on the dropping mercury working electrode (DME. In Britton-Robinson (B-R buffer solution of pH 1.5, MG had a well-defined second order derivative linear sweep voltammetric reductive peak at –0.618 V (vs. SCE. After the addition of heparin into the MG solution, the reductive peak current decreased apparently without the movement of peak potential. Based on the difference of the peak current, a new voltammetric method for the determination of heparin was established. The conditions for the binding reaction and the electrochemical detection were optimized. Under the selected experimental conditions the difference of peak current was directly proportional to the concentration of heparin in the range from 0.3 to 10.0 mg/L with the linear regression equation as ∆ip″ (nA = 360.19 C (mg/L + 178.88 (n = 15, γ = 0.998 and the detection limit as 0.28 mg/L (3σ. The effects of coexisting substances such as metal ions, amino acids on the determination of heparin were investigated and the results showed that this method had good selectivity. This method was further applied to determine the heparin content in heparin sodium injection samples with satisfactory results and good recovery. The stoichiometry of the biocomplex was calculated by the electrochemical method and the binding mechanism was further discussed.

  6. An algorithm for reduct cardinality minimization

    KAUST Repository

    AbouEisha, Hassan M.

    2013-12-01

    This is devoted to the consideration of a new algorithm for reduct cardinality minimization. This algorithm transforms the initial table to a decision table of a special kind, simplify this table, and use a dynamic programming algorithm to finish the construction of an optimal reduct. Results of computer experiments with decision tables from UCI ML Repository are discussed. © 2013 IEEE.

  7. An algorithm for reduct cardinality minimization

    KAUST Repository

    AbouEisha, Hassan M.; Al Farhan, Mohammed; Chikalov, Igor; Moshkov, Mikhail

    2013-01-01

    This is devoted to the consideration of a new algorithm for reduct cardinality minimization. This algorithm transforms the initial table to a decision table of a special kind, simplify this table, and use a dynamic programming algorithm to finish the construction of an optimal reduct. Results of computer experiments with decision tables from UCI ML Repository are discussed. © 2013 IEEE.

  8. Parallel Algorithms for Groebner-Basis Reduction

    Science.gov (United States)

    1987-09-25

    22209 ELEMENT NO. NO. NO. ACCESSION NO. 11. TITLE (Include Security Classification) * PARALLEL ALGORITHMS FOR GROEBNER -BASIS REDUCTION 12. PERSONAL...All other editions are obsolete. Productivity Engineering in the UNIXt Environment p Parallel Algorithms for Groebner -Basis Reduction Technical Report

  9. Parent heparin and daughter LMW heparin correlation analysis using LC-MS and NMR

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Xinyue, E-mail: liux22@rpi.edu [National Glycoengineering Research Center, Shandong Provincial Key Laboratory of Carbohydrate Chemistry and Glycobiology, State Key Laboratory of Microbial Technology, Shandong University, Jinan, Shandong, 250100 (China); Department of Chemistry and Chemical Biology, Department of Chemical and Biological Engineering, Department of Biology, Department of Biomedical Engineering, Center for Biotechnology and Interdisciplinary Studies, Rensselaer Polytechnic Institute, Troy, NY, 12180 (United States); St Ange, Kalib, E-mail: stangk2@rpi.edu [Department of Chemistry and Chemical Biology, Department of Chemical and Biological Engineering, Department of Biology, Department of Biomedical Engineering, Center for Biotechnology and Interdisciplinary Studies, Rensselaer Polytechnic Institute, Troy, NY, 12180 (United States); Wang, Xiaohua, E-mail: wangx35@rpi.edu [Department of Chemistry and Chemical Biology, Department of Chemical and Biological Engineering, Department of Biology, Department of Biomedical Engineering, Center for Biotechnology and Interdisciplinary Studies, Rensselaer Polytechnic Institute, Troy, NY, 12180 (United States); School of Computer and Information, Hefei University of Technology, Hefei (China); Lin, Lei, E-mail: Linl5@rpi.edu [Department of Chemistry and Chemical Biology, Department of Chemical and Biological Engineering, Department of Biology, Department of Biomedical Engineering, Center for Biotechnology and Interdisciplinary Studies, Rensselaer Polytechnic Institute, Troy, NY, 12180 (United States); Zhang, Fuming, E-mail: zhangf2@rpi.edu [Department of Chemistry and Chemical Biology, Department of Chemical and Biological Engineering, Department of Biology, Department of Biomedical Engineering, Center for Biotechnology and Interdisciplinary Studies, Rensselaer Polytechnic Institute, Troy, NY, 12180 (United States); and others

    2017-04-08

    Heparin is a structurally complex, polysaccharide anticoagulant derived from livestock, primarily porcine intestinal tissues. Low molecular weight (LMW) heparins are derived through the controlled partial depolymerization of heparin. Increased manufacturing and regulatory concerns have provided the motivation for the development of more sophisticated analytical methods for determining both their structure and pedigree. A strategy, for the comprehensive comparison of parent heparins and their LMW heparin daughters, is described that relies on the analysis of monosaccharide composition, disaccharide composition, and oligosaccharide composition. Liquid chromatography-mass spectrometry is rapid, robust, and amenable to automated processing and interpretation of both top-down and bottom-up analyses. Nuclear magnetic resonance spectroscopy provides complementary top-down information on the chirality of the uronic acid residues and glucosamine substitution. Principal component analysis (PCA) was applied to the normalized abundance of oligosaccharides, calculated in the bottom-up analysis, to show parent and daughter correlation in oligosaccharide composition. Using these approaches, six pairs of parent heparins and their daughter generic enoxaparins from two different manufacturers were comprehensively analyzed. Enoxaparin is the most widely used LMW heparin and is prepared through controlled chemical β-eliminative cleavage of porcine intestinal heparin. Lovenox{sup ®}, the innovator version of enoxaparin marketed in the US, was analyzed as a reference for the daughter LMW heparins. The results, show similarities between LMW heparins from two different manufacturers with Lovenox{sup ®}, excellent lot-to-lot consistency of products from each manufacturer, and detects a correlation between each parent heparin and daughter LMW heparin. - Highlights: • Low molecular weight heparins prepared from different heparin parents were analyzed. • An integrated analytical

  10. Parent heparin and daughter LMW heparin correlation analysis using LC-MS and NMR

    International Nuclear Information System (INIS)

    Liu, Xinyue; St Ange, Kalib; Wang, Xiaohua; Lin, Lei; Zhang, Fuming

    2017-01-01

    Heparin is a structurally complex, polysaccharide anticoagulant derived from livestock, primarily porcine intestinal tissues. Low molecular weight (LMW) heparins are derived through the controlled partial depolymerization of heparin. Increased manufacturing and regulatory concerns have provided the motivation for the development of more sophisticated analytical methods for determining both their structure and pedigree. A strategy, for the comprehensive comparison of parent heparins and their LMW heparin daughters, is described that relies on the analysis of monosaccharide composition, disaccharide composition, and oligosaccharide composition. Liquid chromatography-mass spectrometry is rapid, robust, and amenable to automated processing and interpretation of both top-down and bottom-up analyses. Nuclear magnetic resonance spectroscopy provides complementary top-down information on the chirality of the uronic acid residues and glucosamine substitution. Principal component analysis (PCA) was applied to the normalized abundance of oligosaccharides, calculated in the bottom-up analysis, to show parent and daughter correlation in oligosaccharide composition. Using these approaches, six pairs of parent heparins and their daughter generic enoxaparins from two different manufacturers were comprehensively analyzed. Enoxaparin is the most widely used LMW heparin and is prepared through controlled chemical β-eliminative cleavage of porcine intestinal heparin. Lovenox"®, the innovator version of enoxaparin marketed in the US, was analyzed as a reference for the daughter LMW heparins. The results, show similarities between LMW heparins from two different manufacturers with Lovenox"®, excellent lot-to-lot consistency of products from each manufacturer, and detects a correlation between each parent heparin and daughter LMW heparin. - Highlights: • Low molecular weight heparins prepared from different heparin parents were analyzed. • An integrated analytical approach relied

  11. Algorithm FIRE-Feynman Integral REduction

    International Nuclear Information System (INIS)

    Smirnov, A.V.

    2008-01-01

    The recently developed algorithm FIRE performs the reduction of Feynman integrals to master integrals. It is based on a number of strategies, such as applying the Laporta algorithm, the s-bases algorithm, region-bases and integrating explicitly over loop momenta when possible. Currently it is being used in complicated three-loop calculations.

  12. Cutaneous reactions to heparin therapy: when are they caused by heparin allergy?

    Directory of Open Access Journals (Sweden)

    Giuliana Zisa

    2013-03-01

    Full Text Available Introduction: Little is known about the incidence and causes of heparin-induced skin lesions. The most commonly reported causes are delayed-type hypersensitivity reactions. We describe 3 patients who were referred to our staff between March and October 2009 for suspected heparin allergies. All were scheduled to undergo major surgery (cardiovascular or orthopedic. Materials and methods: All 3 patients reported the development of itchy, erythematous rashes a few days after the subcutaneous administration of heparin (nadroparin calcium in cases 1 and 2, unspecified in case 3. Each of them underwent a diagnostic work-up for heparin allergy, which included prick and intradermal tests with commonly used heparins and patch testing with undiluted heparins and disinfectants. Results: Patch tests with disinfectants were negative in all 3 cases. In case 2, all allergological tests were negative. In cases 1 and 3, delayed positivity emerged for nadroparin calcium and at least one other heparin tested. Intravenous and/or subcutaneous provocation testing was done with an alternative heparin which produced negative results in skin tests (heparin sodium in case 1, pentasaccharide fondaparinux in case 3. In both cases the alternative drug was tolerated. After our evaluation, all 3 patients underwent surgery with no heparin-related complications. Discussion: The presenting clinical features in these 3 cases provided no information on which reactions were likely to be allergic: all 3 patients presented with similar local delayed reaction. The allergic reactions were identified only after cutaneous testing.

  13. N-Dimensional LLL Reduction Algorithm with Pivoted Reflection

    Directory of Open Access Journals (Sweden)

    Zhongliang Deng

    2018-01-01

    Full Text Available The Lenstra-Lenstra-Lovász (LLL lattice reduction algorithm and many of its variants have been widely used by cryptography, multiple-input-multiple-output (MIMO communication systems and carrier phase positioning in global navigation satellite system (GNSS to solve the integer least squares (ILS problem. In this paper, we propose an n-dimensional LLL reduction algorithm (n-LLL, expanding the Lovász condition in LLL algorithm to n-dimensional space in order to obtain a further reduced basis. We also introduce pivoted Householder reflection into the algorithm to optimize the reduction time. For an m-order positive definite matrix, analysis shows that the n-LLL reduction algorithm will converge within finite steps and always produce better results than the original LLL reduction algorithm with n > 2. The simulations clearly prove that n-LLL is better than the original LLL in reducing the condition number of an ill-conditioned input matrix with 39% improvement on average for typical cases, which can significantly reduce the searching space for solving ILS problem. The simulation results also show that the pivoted reflection has significantly declined the number of swaps in the algorithm by 57%, making n-LLL a more practical reduction algorithm.

  14. Chitosan-capped gold nanoparticles for selective and colorimetric sensing of heparin

    International Nuclear Information System (INIS)

    Chen, Zhanguang; Wang, Zhen; Chen, Xi; Xu, Haixiong; Liu, Jinbin

    2013-01-01

    In this contribution, novel chitosan-stabilized gold nanoparticles (AuNPs) were prepared by mixing chitosan with citrate-reductive AuNPs under appropriate conditions. The as-prepared chitosan-stabilized AuNPs were positively charged and highly stably dispersed in aqueous solution. They exhibited weak resonance light scattering (RLS) intensity and a wine red color. In addition, the chitosan-stabilized AuNPs were successfully utilized as novel sensitive probes for the detection of heparin for the first time. It was found that the addition of heparin induced a strong increase of RLS intensity for AuNPs and the color change from red to blue. The increase in RLS intensity and the color change of chitosan-stabilized AuNPs caused by heparin allowed the sensitive detection of heparin in the range of 0.2–60 μM (∼6.7 U/mL). The detection limit for heparin is 0.8 μM at a signal-to-noise ratio of 3. The present sensor for heparin detection possessed a low detection limit and wide linear range. Additionally, the proposed method was also applied to the detection of heparin in biological media with satisfactory results

  15. Chitosan-capped gold nanoparticles for selective and colorimetric sensing of heparin

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Zhanguang, E-mail: kqlu@stu.edu.cn; Wang, Zhen; Chen, Xi [Shantou University, Department of Chemistry (China); Xu, Haixiong [Shantou Central Hospital, Affiliated Shantou Hospital of SUN YAT-SEN University (China); Liu, Jinbin [University of Texasat Dallas, Department of Chemistry (United States)

    2013-09-15

    In this contribution, novel chitosan-stabilized gold nanoparticles (AuNPs) were prepared by mixing chitosan with citrate-reductive AuNPs under appropriate conditions. The as-prepared chitosan-stabilized AuNPs were positively charged and highly stably dispersed in aqueous solution. They exhibited weak resonance light scattering (RLS) intensity and a wine red color. In addition, the chitosan-stabilized AuNPs were successfully utilized as novel sensitive probes for the detection of heparin for the first time. It was found that the addition of heparin induced a strong increase of RLS intensity for AuNPs and the color change from red to blue. The increase in RLS intensity and the color change of chitosan-stabilized AuNPs caused by heparin allowed the sensitive detection of heparin in the range of 0.2-60 {mu}M ({approx}6.7 U/mL). The detection limit for heparin is 0.8 {mu}M at a signal-to-noise ratio of 3. The present sensor for heparin detection possessed a low detection limit and wide linear range. Additionally, the proposed method was also applied to the detection of heparin in biological media with satisfactory results.

  16. Interactions between nattokinase and heparin/GAGs.

    Science.gov (United States)

    Zhang, Fuming; Zhang, Jianhua; Linhardt, Robert J

    2015-12-01

    Nattokinase (NK) is a serine protease extracted from a traditional Japanese food called natto. Due to its strong fibrinolytic and thrombolytic activity, NK is regarded as a valuable dietary supplement or nutraceutical for the oral thrombolytic therapy. In addition, NK has been investigated for some other medical applications including treatment of hypertension, Alzheimer's disease, and vitreoretinal disorders. The most widely used clinical anticoagulants are heparin and low molecular weight heparins. The interactions between heparin and proteins modulate diverse patho-physiological processes and heparin modifies the activity of serine proteases. Indeed, heparin plays important roles in almost all of NK's potential therapeutically applications. The current report relies on surface plasmon resonance spectroscopy to examine NK interacting with heparin as well as other glycosaminoglycans (GAGs). These studies showed that NK is a heparin binding protein with an affinity of ~250 nM. Examination with differently sized heparin oligosaccharides indicated that the interaction between NK and heparin is chain-length dependent and the minimum size for heparin binding is a hexasaccharide. Studies using chemically modified heparin showed the 6-O-sulfo as well as the N-sulfo groups but not the 2-O-sulfo groups within heparin, are essential for heparin's interaction with NK. Other GAGs (including HS, DS, and CSE) displayed modest binding affinity to NK. NK also interfered with other heparin-protein interactions, including heparin's interaction with antithrombin and fibroblast growth factors.

  17. P-selectin- and heparanase-dependent antimetastatic activity of non-anticoagulant heparins.

    Science.gov (United States)

    Hostettler, Nina; Naggi, Annamaria; Torri, Giangiacomo; Ishai-Michaeli, Riva; Casu, Benito; Vlodavsky, Israel; Borsig, Lubor

    2007-11-01

    Vascular cell adhesion molecules, P- and L-selectins, facilitate metastasis of cancer cells in mice by mediating interactions with platelets, endothelium, and leukocytes. Heparanase is an endoglycosidase that degrades heparan sulfate of extracellular matrix, thereby promoting tumor invasion and metastasis. Heparin is known to efficiently attenuate metastasis in different tumor models. Here we identified modified, nonanticoagulant species of heparin that specifically inhibit selectin-mediated cell-cell interactions, heparanase enzymatic activity, or both. We show that selective inhibition of selectin interactions or heparanase with specific heparin derivatives in mouse models of MC-38 colon carcinoma and B16-BL6 melanoma attenuates metastasis. Selectin-specific heparin derivatives attenuated metastasis of MC-38 carcinoma, but heparanase-specific derivatives had no effect, in accordance with the virtual absence of heparanase activity in these cells. Heparin derivatives had no further effect on metastasis in mice deficient in P- and L-selectin, indicating that selectins are the primary targets of heparin antimetastatic activity. Selectin-specific and heparanase-specific derivatives attenuated metastasis of B16-BL6 melanomas to a similar extent. When mice were injected with a derivative containing both heparanase and selectin inhibitory activity, no additional attenuation of metastasis could be observed. Thus, selectin-specific heparin derivatives efficiently attenuated metastasis of both tumor cell types whereas inhibition of heparanase led to reduction of metastasis only in tumor cells producing heparanase.

  18. Sterilization of heparinized cuprophan hemodialysis membranes

    OpenAIRE

    ten Hoopen, Hermina W.M.; Hinrichs, W.L.J.; Hinrichs, W.L.J.; Engbers, G.H.M.; Feijen, Jan

    1996-01-01

    The effects of sterilization of dry heparinized Cuprophan hemodialysis membranes by means of ethylene oxide (EtO) exposure, gamma irradiation, or steam on the anticoagulant activity and chemical characteristics of immobilized heparin and the permeability of the membrane were investigated. Sterilization did not result in a release of heparin or heparin fragments from heparinized Cuprophan. Sterilization of heparinized Cuprophan by means of EtO exposure and gamma irradiation induced a slight, i...

  19. Heparin pharmacovigilance in Brazil.

    Science.gov (United States)

    Junqueira, Daniela Rezende Garcia; Viana, Thércia Guedes; Peixoto, Eliane R de M; Barros, Fabiana C R de; Carvalho, Maria das Graças; Perini, Edson

    2011-01-01

    To investigate the biological origin of injectable unfractioned heparin available in Brazilian market by discussing the impact of the profile of commercial products and the changes in heparin monograph on the drug safety. The Anvisa data base for the Registered Products of Pharmaceutical Companies and the Dictionary of Pharmaceutical Specialties (DEF 2008/2009) were searched. A survey with industries having an active permission for marketing the drug in Brazil was conducted. Five companies were granted a permission to market unfractioned heparin in Brazil. Three of them are porcine in origin and two of them are bovine in origin, with only one explicitly showing this information in the package insert. The effectiveness and safety of heparin studied in non-Brazilian populations may not represent the Brazilian reality, since most countries no longer produce bovine heparin. The currently marketed heparin has approximately 10% less anticoagulant activity than that previously produced and this change may have clinical implications. Evidence about the lack of dose interchangeability between bovine and porcine heparins and the unique safety profile of these drugs indicates the need to follow the treatment and the patients' response. Events threatening the patient's safety must be reported to the pharmacovigilance system in each particular country.

  20. Oral heparin results in the appearance of heparin fragments in the plasma of rats

    International Nuclear Information System (INIS)

    Larsen, A.K.; Lund, D.P.; Langer, R.; Folkman, J.

    1986-01-01

    We have previously shown that angiogenesis inhibition and tumor regression can be accomplished by combinations of heparin or heparin fragments with cortisone. Oral heparin was also effective in combination with cortisone. We now show that a single oral dose of [ 35 S]heparin or [ 3 H]heparin (15,000 units/kg) results in continuous release of radioactive material into the bloodstream for at least 12 hr. This is associated with the presence of anti-factor Xa activity at a level of approximately equal to 0.1 unit/ml. The radioactive material is identified as oligo-, di-, and monosaccharides by its behavior in chromatographic systems, its possession of anti-factor Xa activity, and the effect of treatment with bacterial heparinase. The heparin fragments are extensively metabolized to fragments without anti-factor Xa activity that are readily subject to urinary excretion

  1. Heparin: Past, Present, and Future.

    Science.gov (United States)

    Oduah, Eziafa I; Linhardt, Robert J; Sharfstein, Susan T

    2016-07-04

    Heparin, the most widely used anticoagulant drug in the world today, remains an animal-derived product with the attendant risks of adulteration and contamination. A contamination crisis in 2007-2008 increased the impetus to provide non-animal-derived sources of heparin, produced under cGMP conditions. In addition, recent studies suggest that heparin may have significant antineoplastic activity, separate and distinct from its anticoagulant activity, while other studies indicate a role for heparin in treating inflammation, infertility, and infectious disease. A variety of strategies have been proposed to produce a bioengineered heparin. In this review, we discuss several of these strategies including microbial production, mammalian cell production, and chemoenzymatic modification. We also propose strategies for creating "designer" heparins and heparan-sulfates with various biochemical and physiological properties.

  2. Low molecular weight heparin versus unfractionated heparin in the initial treatment of venous thromboembolism

    NARCIS (Netherlands)

    Hettiarachchi, R. J.; Prins, M. H.; Lensing, A. W.; Buller, H. R.

    1998-01-01

    In this review, we analyze data from randomized trials in which low molecular weight heparin was compared with unfractionated heparin, both to estimate the treatment effect of low molecular weight heparin in the initial treatment of venous thromboembolism and to evaluate the effect of the varied

  3. Targeting Heparin to Collagen within Extracellular Matrix Significantly Reduces Thrombogenicity and Improves Endothelialization of Decellularized Tissues.

    Science.gov (United States)

    Jiang, Bin; Suen, Rachel; Wertheim, Jason A; Ameer, Guillermo A

    2016-12-12

    Thrombosis within small-diameter vascular grafts limits the development of bioartificial, engineered vascular conduits, especially those derived from extracellular matrix (ECM). Here we describe an easy-to-implement strategy to chemically modify vascular ECM by covalently linking a collagen binding peptide (CBP) to heparin to form a heparin derivative (CBP-heparin) that selectively binds a subset of collagens. Modification of ECM with CBP-heparin leads to increased deposition of functional heparin (by ∼7.2-fold measured by glycosaminoglycan composition) and a corresponding reduction in platelet binding (>70%) and whole blood clotting (>80%) onto the ECM. Furthermore, addition of CBP-heparin to the ECM stabilizes long-term endothelial cell attachment to the lumen of ECM-derived vascular conduits, potentially through recruitment of heparin-binding growth factors that ultimately improve the durability of endothelialization in vitro. Overall, our findings provide a simple yet effective method to increase deposition of functional heparin on the surface of ECM-based vascular grafts and thereby minimize thrombogenicity of decellularized tissue, overcoming a significant challenge in tissue engineering of bioartificial vessels and vascularized organs.

  4. Collection of heparinized plasma by plasmapheresis

    NARCIS (Netherlands)

    van der Meer, P. F.; Vrielink, H.; Pietersz, R. N.; Dekker, W. J.; Reesink, H. W.

    1999-01-01

    BACKGROUND AND OBJECTIVES: Heparinized plasma can be used for exchange transfusions in neonates and is usually collected by drawing whole blood using heparin as anticoagulant. The heparinized red blood cells and buffy coat cannot be used and are therefore discarded. To collect heparinized plasma

  5. Analysis and characterization of heparin impurities.

    Science.gov (United States)

    Beni, Szabolcs; Limtiaco, John F K; Larive, Cynthia K

    2011-01-01

    This review discusses recent developments in analytical methods available for the sensitive separation, detection and structural characterization of heparin contaminants. The adulteration of raw heparin with oversulfated chondroitin sulfate (OSCS) in 2007-2008 spawned a global crisis resulting in extensive revisions to the pharmacopeia monographs on heparin and prompting the FDA to recommend the development of additional physicochemical methods for the analysis of heparin purity. The analytical chemistry community quickly responded to this challenge, developing a wide variety of innovative approaches, several of which are reported in this special issue. This review provides an overview of methods of heparin isolation and digestion, discusses known heparin contaminants, including OSCS, and summarizes recent publications on heparin impurity analysis using sensors, near-IR, Raman, and NMR spectroscopy, as well as electrophoretic and chromatographic separations.

  6. Heparin-induced thrombocytopenia: real-world issues.

    Science.gov (United States)

    Linkins, Lori-Ann; Warkentin, Theodore E

    2011-09-01

    Heparin-induced thrombocytopenia (HIT) is a prothrombotic drug reaction caused by platelet-activating antibodies. HIT sera often activate platelets without needing heparin-such heparin-"independent" platelet activation can be associated with HIT beginning or worsening despite stopping heparin ("delayed-onset HIT"). We address important issues in HIT diagnosis and therapy, using a recent cohort of HIT patients to illustrate influences of heparin type; triggers for HIT investigation; serological features of heparin-independent platelet activation; and treatment. In our cohort of recent HIT cases ( N = 13), low-molecular-weight heparin (dalteparin) was a common causative agent ( N = 8, 62%); most patients were diagnosed after HIT-thrombosis had occurred; and danaparoid was the most frequently selected treatment. Heparin-independent platelet activation was common (7/13 [54%]) and predicted slower platelet count recovery (>1 week) among evaluable patients (5/5 vs 1/6; P = 0.015). In our experience with argatroban-treated patients, HIT-associated consumptive coagulopathy confounds anticoagulant monitoring. Our observations provide guidance on practical aspects of HIT diagnosis and management. Thieme Medical Publishers.

  7. 77 FR 7584 - Draft Guidance for Industry on Heparin for Drug and Medical Device Use; Monitoring Crude Heparin...

    Science.gov (United States)

    2012-02-13

    ... strategies to ensure that the heparin supply chain is not contaminated with OSCS or any non- porcine origin... device manufacturers of finished products, and others to the potential risk of crude heparin...) among patients injected with heparin sodium in 2008, FDA identified the contaminant OSCS in heparin API...

  8. 78 FR 38058 - Guidance for Industry on Heparin for Drug and Medical Device Use: Monitoring Crude Heparin for...

    Science.gov (United States)

    2013-06-25

    ... public health. FDA developed this guidance to alert manufacturers to the risks of crude heparin contaminants and to recommend strategies to ensure that the heparin supply chain is not contaminated with OSCS... heparin sodium in 2008, FDA identified the contaminant OSCS in crude heparin sourced from China. FDA is...

  9. Sensitive detection of oversulfated chondroitin sulfate in heparin sodium or crude heparin with a colorimetric microplate based assay.

    Science.gov (United States)

    Sommers, Cynthia D; Mans, Daniel J; Mecker, Laura C; Keire, David A

    2011-05-01

    In this work we describe a 96-well microplate assay for oversulfated chondroitin sulfate A (OSCS) in heparin, based on a water-soluble cationic polythiophene polymer (3-(2-(N-(N'-methylimidazole))ethoxy)-4-methylthiophene (LPTP)) and heparinase digestion of heparin. The assay takes advantage of several unique properties of heparin, OSCS, and LPTP, including OSCS inhibition of heparinase I and II activity, the molecular weight dependence of heparin-LPTP spectral shifts, and the distinct association of heparin fragments and OSCS to LPTP. These factors combine to enable detection of the presence of 0.003% w/w spiked OSCS in 10 μg of heparin sodium active pharmaceutical ingredient (API) using a plate reader and with visual detection to 0.1% levels. The same detection limit for OSCS was observed in the presence of 10% levels of dermatan sulfate (DS) or chondroitin sulfate A (CSA) impurities. In addition, we surveyed a selection of crude heparin samples received by the agency in 2008 and 2009 to determine average and extreme DS, CSA, and galactosamine weight percent levels. In the presence of these impurities and the variable heparin content in the crude heparin samples, spiked OSCS was reliably detected to the 0.1% w/w level using a plate reader. Finally, authentically OSCS contaminated heparin sodium API and crude samples were distinguished visually by color from control samples using the LPTP/heparinase test.

  10. Click-coated, heparinized, decellularized vascular grafts.

    Science.gov (United States)

    Dimitrievska, Sashka; Cai, Chao; Weyers, Amanda; Balestrini, Jenna L; Lin, Tylee; Sundaram, Sumati; Hatachi, Go; Spiegel, David A; Kyriakides, Themis R; Miao, Jianjun; Li, Guoyun; Niklason, Laura E; Linhardt, Robert J

    2015-02-01

    A novel method enabling the engineering of a dense and appropriately oriented heparin-containing layer on decellularized aortas has been developed. Amino groups of decellularized aortas were first modified to azido groups using 3-azidobenzoic acid. Azide-clickable dendrons were attached onto the azido groups through "alkyne-azide" click chemistry, affording a tenfold amplification of adhesions sites. Dendron end groups were finally decorated with end-on modified heparin chains. Heparin chains were oriented like heparan sulfate groups on native endothelial cells surface. X-ray photoelectron spectroscopy, nuclear magnetic resonance imaging, mass spectrometry and Fourier transform infrared FTIR spectroscopy were used to characterize the synthesis steps, building the final heparin layered coatings. The continuity of the heparin coating was verified using fluorescent microscopy and histological analysis. The efficacy of heparin linkage was demonstrated with factor Xa anti-thrombogenic assay and platelet adhesion studies. The results suggest that oriented heparin immobilization to decellularized aortas may improve the in vivo blood compatibility of decellularized aortas and vessels. Copyright © 2014 Acta Materialia Inc. All rights reserved.

  11. Heparin for assisted reproduction.

    Science.gov (United States)

    Akhtar, Muhammad A; Sur, Shyamaly; Raine-Fenning, Nick; Jayaprakasan, Kannamannadiar; Thornton, Jim G; Quenby, Siobhan

    2013-08-17

    Heparin as an adjunct in assisted reproduction (peri-implantation heparin) is given at or after egg collection or at embryo transfer during assisted reproduction. Heparin has been advocated to improve embryo implantation and clinical outcomes.  It has been proposed that heparin enhances the intra-uterine environment by improving decidualisation with an associated activation of growth factors and a cytokine expression profile in the endometrium that is favourable to pregnancy. To investigate whether the administration of heparin around the time of implantation (peri-implantation heparin) improves clinical outcomes in subfertile women undergoing assisted reproduction. A comprehensive and exhaustive search strategy was developed in consultation with the Trials Search Co-ordinator of the Cochrane Menstrual Disorders and Subfertility Group (MDSG). The strategy was used in an attempt to identify all relevant studies regardless of language or publication status (published, unpublished, in press, and in progress). Relevant trials were identified from both electronic databases and other resources (last search 6 May 2013). All randomised controlled trials (RCTs) were included where peri-implantation heparin was given during assisted reproduction. Peri-implantation low molecular weight heparin (LMWH) during IVF/ICSI was given at or after egg collection or at embryo transfer in the included studies. Live birth rate was the primary outcome. Two review authors independently assessed the eligibility and quality of trials and extracted relevant data. The quality of the evidence was evaluated using GRADE methods. Three RCTs (involving 386 women) were included in the review.Peri-implantation LMWH administration during assisted reproduction was associated with a significant improvement in live birth rate compared with placebo or no LMWH (odds ratio (OR) 1.77, 95% confidence interval (CI) 1.07 to 2.90, three studies, 386 women, I(2) = 51%, very low quality evidence with high

  12. ANALYSIS OF PARAMETERIZATION VALUE REDUCTION OF SOFT SETS AND ITS ALGORITHM

    Directory of Open Access Journals (Sweden)

    Mohammed Adam Taheir Mohammed

    2016-02-01

    Full Text Available In this paper, the parameterization value reduction of soft sets and its algorithm in decision making are studied and described. It is based on parameterization reduction of soft sets. The purpose of this study is to investigate the inherited disadvantages of parameterization reduction of soft sets and its algorithm. The algorithms presented in this study attempt to reduce the value of least parameters from soft set. Through the analysis, two techniques have been described. Through this study, it is found that parameterization reduction of soft sets and its algorithm has yielded a different and inconsistency in suboptimal result.

  13. Heparin and heparin-induced thrombocytopenia

    African Journals Online (AJOL)

    2007-06-15

    Jun 15, 2007 ... Heparin is one of the most widely used drugs. It is used routinely for treatment and thromboprophylaxis in a broad spectrum of conditions including venous thromboembolism, atrial fibrillation, acute coronary syndromes, peripheral vascular disease and to maintain the patency of indwelling catheters and ...

  14. Results of the HepZero study comparing heparin-grafted membrane and standard care show that heparin-grafted dialyzer is safe and easy to use for heparin-free dialysis

    NARCIS (Netherlands)

    Laville, Maurice; Dorval, Marc; Ros, Joan Fort; Fay, Renaud; Cridlig, Joelle; Nortier, Joelle L.; Juillard, Laurent; Debska-Slizien, Alicja; Lorente, Loreto Fernandez; Thibaudin, Damien; Franssen, Casper; Schulz, Michael; Moureau, Frederique; Loughraieb, Nathalie; Rossignol, Patrick

    2014-01-01

    Heparin is used to prevent clotting during hemodialysis, but heparin-free hemodialysis is sometimes needed to decrease the risk of bleeding. The HepZero study is a randomized, multicenter international controlled open-label trial comparing no-heparin hemodialysis strategies designed to assess

  15. Prevention of equine herpesvirus myeloencephalopathy - Is heparin a novel option? A case report.

    Science.gov (United States)

    Walter, Jasmin; Seeh, Christoph; Fey, Kerstin; Bleul, Ulrich; Osterrieder, Nikolaus

    2016-10-12

    Equine herpesvirus myeloencephalopathy (EHM) is a severe manifestation of equine herpesvirus 1 (EHV-1) infection. Prevention and treatment of EHM during EHV-1 outbreaks is critical, but no reliable and tested specific medication is available. Due to the thromboischemic nature of EHM and due to the fact that EHV-1 entry in cells is blocked by heparin, it was hypothesized that this compound may be useful in reduction of EHM incidence and severity. Therefore, during an acute EHV-1 outbreak with the neuropathogenic G 2254 /D 752 Pol variant, metaphylactic treatment with heparin to prevent EHM was initiated. Clinical signs were present in 61 horses (fever n = 55; EHM n = 8; abortion n = 6). Heparin (25000 IU subcutaneously twice daily for 3 days) was given to 31 febrile horses from day 10 of the outbreak, while the first 30 horses exhibiting fever remained untreated. Treatment outcome was analyzed retrospectively. Heparin-treated horses showed a lower EHM incidence (1/31; 3.2%) than untreated horses (7/30; 23.3%; p = 0.03). Results indicate that heparin may be useful for prevention of EHM during an EHV-1 outbreak. These promising data highlight the need for randomized and possibly blinded studies for the use of heparin in EHV-1 outbreaks.

  16. Layer-by-Layer Heparinization of the Cell Surface by Using Heparin-Binding Peptide Functionalized Human Serum Albumin.

    Science.gov (United States)

    Song, Guowei; Hu, Yaning; Liu, Yusheng; Jiang, Rui

    2018-05-20

    Layer-by-layer heparinization of therapeutic cells prior to transplantation is an effective way to inhibit the instant blood-mediated inflammatory reactions (IBMIRs), which are the major cause of early cell graft loss during post-transplantation. Here, a conjugate of heparin-binding peptide (HBP) and human serum albumin (HSA), HBP-HSA, was synthesized by using heterobifunctional crosslinker. After the first heparin layer was coated on human umbilical vein endothelial cells (HUVECs) by means of the HBP-polyethylene glycol-phospholipid conjugate, HBP-HSA and heparin were then applied to the cell surface sequentially to form multiple layers. The immobilization and retention of heparin were analyzed by confocal microscopy and flow cytometry, respectively, and the cytotoxity of HBP-HSA was further evaluated by cell viability assay. Results indicated that heparin was successfully introduced to the cell surface in a layer-by-layer way and retained for at least 24 h, while the cytotoxity of HBP-HSA was negligible at the working concentration. Accordingly, this conjugate provides a promising method for co-immobilization of heparin and HSA to the cell surface under physiological conditions with improved biocompatibility.

  17. On distribution reduction and algorithm implementation in inconsistent ordered information systems.

    Science.gov (United States)

    Zhang, Yanqin

    2014-01-01

    As one part of our work in ordered information systems, distribution reduction is studied in inconsistent ordered information systems (OISs). Some important properties on distribution reduction are studied and discussed. The dominance matrix is restated for reduction acquisition in dominance relations based information systems. Matrix algorithm for distribution reduction acquisition is stepped. And program is implemented by the algorithm. The approach provides an effective tool for the theoretical research and the applications for ordered information systems in practices. For more detailed and valid illustrations, cases are employed to explain and verify the algorithm and the program which shows the effectiveness of the algorithm in complicated information systems.

  18. Severe heparin osteoporosis in pregnancy.

    OpenAIRE

    Griffiths, H. T.; Liu, D. T.

    1984-01-01

    A case of severe osteoporosis following administration of low dose subcutaneous heparin in pregnancy is reported. Possible reasons for the condition are suggested which caution against the indiscriminate use of subcutaneous heparin in pregnancy.

  19. Implementing peak load reduction algorithms for household electrical appliances

    International Nuclear Information System (INIS)

    Dlamini, Ndumiso G.; Cromieres, Fabien

    2012-01-01

    Considering household appliance automation for reduction of household peak power demand, this study explored aspects of the interaction between household automation technology and human behaviour. Given a programmable household appliance switching system, and user-reported appliance use times, we simulated the load reduction effectiveness of three types of algorithms, which were applied at both the single household level and across all 30 households. All three algorithms effected significant load reductions, while the least-to-highest potential user inconvenience ranking was: coordinating the timing of frequent intermittent loads (algorithm 2); moving period-of-day time-flexible loads to off-peak times (algorithm 1); and applying short-term time delays to avoid high peaks (algorithm 3) (least accommodating). Peak reduction was facilitated by load interruptibility, time of use flexibility and the willingness of users to forgo impulsive appliance use. We conclude that a general factor determining the ability to shift the load due to a particular appliance is the time-buffering between the service delivered and the power demand of an appliance. Time-buffering can be ‘technologically inherent’, due to human habits, or realised by managing user expectations. There are implications for the design of appliances and home automation systems. - Highlights: ► We explored the interaction between appliance automation and human behaviour. ► There is potential for considerable load shifting of household appliances. ► Load shifting for load reduction is eased with increased time buffering. ► Design, human habits and user expectations all influence time buffering. ► Certain automation and appliance design features can facilitate load shifting.

  20. Allergic anaphylaxis due to subcutaneously injected heparin

    Directory of Open Access Journals (Sweden)

    Anders Diana

    2013-01-01

    Full Text Available Abstract Heparins are one of the most used class of anticoagulants in daily clinical practice. Despite their widespread application immune-mediated hypersensitivity reactions to heparins are rare. Among these, the delayed-type reactions to s.c. injected heparins are well-known usually presenting as circumscribed eczematous plaques at the injection sites. In contrast, potentially life-threatening systemic immediate-type anaphylactic reactions to heparins are extremely rare. Recently, some cases of non-allergic anaphylaxis could be attributed to undesirable heparin contaminants. A 43-year-old patient developed severe anaphylaxis symptoms within 5–10 minutes after s.c. injection of enoxaparin. Titrated skin prick testing with wheal and flare responses up to an enoxaparin dilution of 1:10.000 indicated a probable allergic mechanism of the enoxaparin-induced anaphylaxis. The basophil activation test as an additional in-vitro test method was negative. Furthermore, skin prick testing showed rather broad cross-reactivity among different heparin preparations tested. In the presented case, history, symptoms, and results of skin testing strongly suggested an IgE-mediated allergic hypersensitivity against different heparins. Therefore, as safe alternative anticoagulants the patient could receive beneath coumarins the hirudins or direct thrombin inhibitors. Because these compounds have a completely different molecular structure compared with the heparin-polysaccharides.

  1. Interference of heparin in carcinoembryonic antigen radioimmunoassays

    International Nuclear Information System (INIS)

    Wu, J.T.

    1983-01-01

    A false Roche carcinoembryonic antigen (CEA) activity could be detected in all commercial and noncommercial heparin preparations examined. The possibility of 'due to contamination' has been ruled out. Using the Roche procedure, heparin solutions, in the absence of CEA, gave positive CEA activity; on the other hand, no CEA activity was detected in solutions containing only heparin when the Abbott Kit was used. When heparin was present in specimens containing CEA, the Abbott Kit underestimated the CEA activity, whereas the Roche Kit gave false elevated values. However, the negative effect of heparin could be reduced by heat treatment in the presence of plasma proteins. (Auth.)

  2. Changes in heparin dose response slope during cardiac surgery: possible result in inaccuracy in predicting heparin bolus dose requirement to achieve target ACT.

    Science.gov (United States)

    Ichikawa, Junko; Mori, Tetsu; Kodaka, Mitsuharu; Nishiyama, Keiko; Ozaki, Makoto; Komori, Makiko

    2017-09-01

    The substantial interpatient variability in heparin requirement has led to the use of a heparin dose response (HDR) technique. The accuracy of Hepcon-based heparin administration in achieving a target activated clotting time (ACT) using an HDR slope remains controversial. We prospectively studied 86 adult patients scheduled for cardiac surgery requiring cardiopulmonary bypass. The total dose of calculated heparin required for patient and pump priming was administered simultaneously to achieve a target ACT of 450 s for HDR on the Hepcon HMS system. Blood samples were obtained after the induction of anesthesia, at 3 min after heparin administration and after the initiation of CPB to measure kaolin ACT, HDR slope, whole-blood heparin concentration based on the HDR slope and anti-Xa heparin concentration, antithrombin and complete blood count. The target ACT of 450 s was not achieved in 68.6% of patients. Compared with patients who achieved the target ACT, those who failed to achieve their target ACT had a significantly higher platelet count at baseline. Correlation between the HDR slope and heparin sensitivity was poor. Projected heparin concentration and anti-Xa heparin concentration are not interchangeable based on the Bland-Altman analysis. It can be hypothesized that the wide discrepancy in HDR slope versus heparin sensitivity may be explained by an inaccurate prediction of the plasma heparin level and/or the change in HDR of individual patients, depending on in vivo factors such as extravascular sequestration of heparin, decreased intrinsic antithrombin activity level and platelet count and/or activity.

  3. Influence of heparin on radioimmunological assay of ACTH

    International Nuclear Information System (INIS)

    Dupouy, J.P.; Godaut, M.; Chatelain, A.

    1986-01-01

    1 - Heparin traps plasma ACTH, promoting the formation of aggregates with apparent high molecular weight as shown by chromatography on Sephadex G 50 fine columns. The percentage of 125 I-ACTH which appeared in the void volume of the column, increased linearly with the log. dose of heparin. 2 - Heparin at concentrations of up to 100 IU/ml does not impair ACTH adsorption on either silicic acid or Quso G 32 as well as further elution by acetic acid/acetone/water (I: 40: 59; V/V) or HCl O.I N. Silicic acid traps selectively ACTH but not heparin. 3 - Heparin interferes with direct RIA-ACTH in the plasma by decreasing 125 I-ACTH binding to the antibodies and modifying the slope of the standard curve. Unsuitable artefacts induced by heparin, as overestimation or underestimation of plasma ACTH levels by RIA, can be avoid by previous hormone extraction from heparinized plasmas. Such results emphasized the importance of the sample preparation in order to obtain consistent results [fr

  4. Preparation and characterization of microspheres of albumin-heparin conjugates

    NARCIS (Netherlands)

    Kwon, Glen S.; Bae, You Han; Kim, Sung Wan; Cremers, Harry; Cremers, H.F.M.; Feijen, Jan

    1991-01-01

    Albumin-heparin microspheres have been prepared as a new drug carrier. A soluble albumin-heparin conjugate was synthesized by forming amide bonds between human serum albumin and heparin. After purification the albumin-heparin conjugate was crosslinked in a water-in-oil emulsion to form

  5. How to give a heparin shot

    Science.gov (United States)

    ... you put the injection. Storing Your Heparin and Supplies Ask your pharmacist how to store your heparin ... M. is also a founding member of Hi-Ethics and subscribes to the principles of the Health ...

  6. Endogenous heparin levels in the controlled asthmatic patient ...

    African Journals Online (AJOL)

    Background. Since heparin possesses anti-inflammatory properties, it is hypothesised that asthmatic patients have decreased levels of circulating heparin compared with healthy individuals. Design. We compared endogenous heparin levels in controlled asthmatic patients (53 adults) from the Asthma Clinic at ...

  7. Heparin increases food intake through AgRP neurons

    Science.gov (United States)

    Although the widely used anticoagulant drug heparin has been shown to have many other biological functions independent of its anticoagulant role, its effects on energy homeostasis are unknown. Here, we demonstrate that heparin level is negatively associated with nutritional states and that heparin t...

  8. Sterilization of heparinized cuprophan hemodialysis membranes

    NARCIS (Netherlands)

    ten Hoopen, Hermina W.M.; Hinrichs, W.L.J.; Hinrichs, W.L.J.; Engbers, G.H.M.; Feijen, Jan

    1996-01-01

    The effects of sterilization of dry heparinized Cuprophan hemodialysis membranes by means of ethylene oxide (EtO) exposure, gamma irradiation, or steam on the anticoagulant activity and chemical characteristics of immobilized heparin and the permeability of the membrane were investigated.

  9. Structural characterization of pharmaceutical heparins prepared from different animal tissues.

    Science.gov (United States)

    Fu, Li; Li, Guoyun; Yang, Bo; Onishi, Akihiro; Li, Lingyun; Sun, Peilong; Zhang, Fuming; Linhardt, Robert J

    2013-05-01

    Although most pharmaceutical heparin used today is obtained from porcine intestine, heparin has historically been prepared from bovine lung and ovine intestine. There is some regulatory concern about establishing the species origin of heparin. This concern began with the outbreak of mad cow disease in the 1990s and was exacerbated during the heparin shortage in the 2000s and the heparin contamination crisis of 2007-2008. Three heparins from porcine, ovine, and bovine were characterized through state-of-the-art carbohydrate analysis methods with a view profiling their physicochemical properties. Differences in molecular weight, monosaccharide and disaccharide composition, oligosaccharide sequence, and antithrombin III-binding affinity were observed. These data provide some insight into the variability of heparins obtained from these three species and suggest some analytical approaches that may be useful in confirming the species origin of a heparin active pharmaceutical ingredient. Copyright © 2013 Wiley Periodicals, Inc.

  10. Does ′heparin-induced thrombocytopenia′ hit our minds?

    Directory of Open Access Journals (Sweden)

    Arun R Thangavel

    2016-01-01

    Full Text Available Unfractionated heparin is a widely used drug to prevent deep vein thrombosis and pulmonary emboli in patients at risk. With the advent of newer anticoagulants having lesser side effects, its use has diminished but not out of service. Here, we report a case of deep venous thrombosis, in a patient on prophylactic dose of heparin, which was later found to be a manifestation of heparin-induced thrombocytopenia (HIT. Thrombosis in the presence of heparin prophylaxis should be considered as HIT rather than a failure of anticoagulation.

  11. Heparin- induced thrombocytopenia (HIT: a case report of CABG patient

    Directory of Open Access Journals (Sweden)

    Alireza Jahangirifard

    2016-08-01

    Full Text Available Heparin- induced thrombocytopenia (HIT is an antibody mediated adverse effect of heparin therapy which is classified into two subtypes, HITI which is non-immune, spontaneously reversible thrombocytopenia and; HITII which is an autoimmune-mediated adverse effect of heparin therapy. In this case report, we described a 65-year old male patient with HITII after coronary artery bypass grafting.Key words: Heparin- induced thrombocytopenia, Heparin- induced thrombosis, coronary artery bypass grafting.

  12. Structural and binding studies of SAP-1 protein with heparin.

    Science.gov (United States)

    Yadav, Vikash K; Mandal, Rahul S; Puniya, Bhanwar L; Kumar, Rahul; Dey, Sharmistha; Singh, Sarman; Yadav, Savita

    2015-03-01

    SAP-1 is a low molecular weight cysteine protease inhibitor (CPI) which belongs to type-2 cystatins family. SAP-1 protein purified from human seminal plasma (HuSP) has been shown to inhibit cysteine and serine proteases and exhibit interesting biological properties, including high temperature and pH stability. Heparin is a naturally occurring glycosaminoglycan (with varied chain length) which interacts with a number of proteins and regulates multiple steps in different biological processes. As an anticoagulant, heparin enhances inhibition of thrombin by the serpin antithrombin III. Therefore, we have employed surface plasmon resonance (SPR) to improve our understanding of the binding interaction between heparin and SAP-1 (protease inhibitor). SPR data suggest that SAP-1 binds to heparin with a significant affinity (KD = 158 nm). SPR solution competition studies using heparin oligosaccharides showed that the binding of SAP-1 to heparin is dependent on chain length. Large oligosaccharides show strong binding affinity for SAP-1. Further to get insight into the structural aspect of interactions between SAP-1 and heparin, we used modelled structure of the SAP-1 and docked with heparin and heparin-derived polysaccharides. The results suggest that a positively charged residue lysine plays important role in these interactions. Such information should improve our understanding of how heparin, present in the reproductive tract, regulates cystatins activity. © 2014 John Wiley & Sons A/S.

  13. Profiling Heparin-Chemokine Interactions Using Synthetic Tools

    Science.gov (United States)

    de Paz, Jose L.; Moseman, E. Ashley; Noti, Christian; Polito, Laura; von Andrian, Ulrich H.; Seeberger, Peter H.

    2009-01-01

    Glycosaminoglycans (GAGs), such as heparin or heparan sulfate, are required for the in vivo function of chemokines. Chemokines play a crucial role in the recruitment of leukocyte subsets to sites of inflammation and lymphocytes trafficking. GAG-chemokine interactions mediate cell migration and determine which leukocyte subsets enter tissues. Identifying the exact GAC sequences that bind to particular chemokines is key to understand chemokine function at the molecular level and develop strategies to interfere with chemokine-mediated processes. Here, we characterize the heparin binding profiles of eight chemokines (CCL21, IL-8, CXCL12, CXCL13, CCL19, CCL25, CCL28, and CXCL16) by employing heparin microarrays containing a small library of synthetic heparin oligosaccharides. The chemokines differ significantly in their interactions with heparin oligosaccharides: While some chemokines, (e.g., CCL21) strongly bind to a hexasaccharide containing the GlcNSO3(6-OSO3)-IdoA(2-OSO3) repeating unit, CCL19 does not bind and CXCL12 binds only weakly. The carbohydrate microarray binding results were validated by surface plasmon resonance experiments. In vitro chemotaxis assays revealed that dendrimers coated with the fully sulfated heparin hexasaccharide inhibit lymphocyte migration toward CCL21. Migration toward CXCL12 or CCL19 was not affected. These in vitro homing assays indicate that multivalent synthetic heparin dendrimers inhibit the migration of lymphocytes toward certain chemokine gradients by blocking the formation of a chemokine concentration gradient on GAG endothelial chains. These findings are in agreement with preliminary in vivo measurements of circulating lymphocytes. The results presented here contribute to the understanding of GAG-chemokine interactions, a first step toward the design of novel drugs that modulate chemokine activity. PMID:18030990

  14. 21 CFR 864.7525 - Heparin assay.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Heparin assay. 864.7525 Section 864.7525 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Hematology Kits and Packages § 864.7525 Heparin assay. (a) Identification. A...

  15. Advanced nanocarriers based on heparin and its derivatives for cancer management.

    Science.gov (United States)

    Yang, Xiaoye; Du, Hongliang; Liu, Jiyong; Zhai, Guangxi

    2015-02-09

    To obtain a satisfying anticancer effect, rationally designed nanocarriers are intensively studied. In this field, heparin and its derivatives have been widely attempted recently as potential component of nanocarriers due to their unique biological and physiochemical features, especially the anticancer activity. This review focuses on state-of-the-art nanocarriers with heparin/heparin derivatives as backbone or coating material. At the beginning, the unique advantages of heparin used in cancer nanotechnology are discussed. After that, different strategies of heparin chemical modification are reviewed, laying the foundation of developing various nanocarriers. Then a systematic summary of diverse nanoparticles with heparin as component is exhibited, involving heparin-drug conjugate, polymeric nanoparticles, nanogels, polyelectrolyte complex nanoparticles, and heparin-coated organic and inorganic nanoparticles. The application of these nanoparticles in various novel cancer therapy (containing targeted therapy, magnetic therapy, photodynamic therapy, and gene therapy) will be highlighted. Finally, future challenges and opportunities of heparin-based biomaterials in cancer nanotechnology are discussed.

  16. A sensitive competitive binding assay for exogenous and endogenous heparins

    International Nuclear Information System (INIS)

    Dawes, J.; Pepper, D.S.

    1982-01-01

    A new type of assay for heparins has been devised, in which the test material competes with 125 I-labelled heparin for binding to protamine-Sepharose. The assay is very sensitive and will measure heparin concentrations down to 10 ng ml-1. It responds to both the degree of sulphation and the molecular weight of acidic polysaccharides, but is independent of their biological activities. It can be used to quantitate heparins in biological fluids after pretreatment of the samples with protease. In this way endogenous heparins were measured in normal human serum, plasma and urine. The assay is extremely versatile and has great potential for the investigation of endogenous and exogenous heparins

  17. Characterization of heparin aerosols generated in jet and ultrasonic nebulizers

    DEFF Research Database (Denmark)

    Bendstrup, K.E.; Newhouse, M.T.; Pedersen, Ole Finn

    1999-01-01

    Inhaled heparin has been used for asthma treatment, but results have been inconsistent, probably due to highly varying lung doses. We determined the output per unit time and the particle size distributions of sodium heparin, calcium heparin, and low molecular weight (LMW) heparin formulations in ...... on the exhalation filter, and 15,000 IU was captured on the inhalation filter (inhaled mass). This corresponds to a respirable mass of 10,000 IU of heparin with a high probability of reaching the lower respiratory tract in normal healthy adults....

  18. Effects of heparin on insulin binding and biological activity

    International Nuclear Information System (INIS)

    Kriauciunas, K.M.; Grigorescu, F.; Kahn, C.R.

    1987-01-01

    The effect of heparin, a polyanionic glycosaminoglycan known to alter the function of many proteins, on insulin binding and bioactivity was studied. Cultured human lymphocytes (IM-9) were incubated with varying concentrations of heparin, then extensively washed, and 125 I-labeled insulin binding was measured. Heparin at concentrations used clinically for anticoagulation (1-50 U/ml) inhibited binding in a dose-dependent manner; 50% inhibition of binding occurred with 5-10 U/ml. Scatchard analysis indicated that the decrease in binding was due to a decrease in both the affinity and the apparent number of available insulin receptors. The effect occurred within 10 min at 22 degrees C and persisted even after the cells were extensively washed. Inhibition of insulin binding also occurred when cells were preincubated with heparinized plasma or heparinized serum but not when cells were incubated with normal serum or plasma from blood anticoagulated with EDTA. By contrast, other polyanions and polycations, e.g., poly-L-glutamic acid, poly-L-lysine, succinylated poly-L-lysine, and histone, did not inhibit binding. Heparin also inhibited insulin binding in Epstein-Barr (EB) virus-transformed lymphocytes but had no effect on insulin binding to isolated adipocytes, human erythrocytes, or intact hepatoma cells. When isolated adipocytes were incubated with heparin, there was a dose-dependent inhibition of insulin-stimulated glucose oxidation and, to a lesser extent, of basal glucose oxidation. Although heparin has no effect on insulin binding to intact hepatoma cells, heparin inhibited both insulin binding and insulin-stimulated autophosphorylation in receptors solubilized from these cells

  19. Citrate Anticoagulation for CRRT in Children: Comparison with Heparin

    Directory of Open Access Journals (Sweden)

    Sara Nicole Fernández

    2014-01-01

    Full Text Available Regional anticoagulation with citrate is an alternative to heparin in continuous renal replacement therapies, which may prolong circuit lifetime and decrease hemorrhagic complications. A retrospective comparative cohort study based on a prospective observational registry was conducted including critically ill children undergoing CRRT. Efficacy, measured as circuit survival, and secondary effects of heparin and citrate were compared. 12 patients on CRRT with citrate anticoagulation and 24 patients with heparin anticoagulation were analyzed. Median citrate dose was 2.6 mmol/L. Median calcium dose was 0.16 mEq/kg/h. Median heparin dose was 15 UI/kg/h. Median circuit survival was 48 hours with citrate and 31 hours with heparin (P=0.028. 66.6% of patients treated with citrate developed mild metabolic alkalosis, which was directly related to citrate dose. There were no cases of citrate intoxication: median total calcium/ionic calcium index (CaT/I of 2.16 and a maximum CaT/I of 2.33, without metabolic acidosis. In the citrate group, 45.5% of patients developed hypochloremia and 27.3% hypomagnesemia. In the heparin group, 27.8% developed hypophosphatemia. Three patients were moved from heparin to citrate to control postoperatory bleeding. In conclusion citrate is a safe and effective anticoagulation method for CRRT in children and it achieves longer circuit survival than heparin.

  20. Development and performance analysis of a lossless data reduction algorithm for voip

    International Nuclear Information System (INIS)

    Misbahuddin, S.; Boulejfen, N.

    2014-01-01

    VoIP (Voice Over IP) is becoming an alternative way of voice communications over the Internet. To better utilize voice call bandwidth, some standard compression algorithms are applied in VoIP systems. However, these algorithms affect the voice quality with high compression ratios. This paper presents a lossless data reduction technique to improve VoIP data transfer rate over the IP network. The proposed algorithm exploits the data redundancies in digitized VFs (Voice Frames) generated by VoIP systems. Performance of proposed data reduction algorithm has been presented in terms of compression ratio. The proposed algorithm will help retain the voice quality along with the improvement in VoIP data transfer rates. (author)

  1. Electrophoresis for the analysis of heparin purity and quality.

    Science.gov (United States)

    Volpi, Nicola; Maccari, Francesca; Suwan, Jiraporn; Linhardt, Robert J

    2012-06-01

    The adulteration of raw heparin with oversulfated chondroitin sulfate (OSCS) in 2007-2008 produced a global crisis resulting in extensive revisions to the pharmacopeia monographs and prompting the FDA to recommend the development of additional methods for the analysis of heparin purity. As a consequence, a wide variety of innovative analytical approaches have been developed for the quality assurance and purity of unfractionated and low-molecular-weight heparins. This review discusses recent developments in electrophoresis techniques available for the sensitive separation, detection, and partial structural characterization of heparin contaminants. In particular, this review summarizes recent publications on heparin quality and related impurity analysis using electrophoretic separations such as capillary electrophoresis (CE) of intact polysaccharides and hexosamines derived from their acidic hydrolysis, and polyacrylamide gel electrophoresis (PAGE) for the separation of heparin samples without and in the presence of its relatively specific depolymerization process with nitrous acid treatment. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Biological distribution of 51Cr-heparin

    International Nuclear Information System (INIS)

    Almeida, M.A.T.M. de.

    1979-01-01

    The kinetics of heparin in normal Wistar rats using the radioactive tracer 51 Cr, has been studied. The labeled and purified 51 Cr-heparin was injected into rats intravenously and by intraperitoneal injection. In measuring the radioactivity of organs it was possible to conclude that the tissues rich in mast cells, liver and spleen, were found to take up the greater amounts of heparin. The curve that represents the logarithm of the concentration of heparin versus time is biexponential. The half-lives of the two exponential were determined. The volume of distribution, the rate constant and the renal clearance were determined by the values of the plasma levels and urinary excretions. The biological half-time, the turnover rate and the turnover time were determined by measuring the residual radioactivity of the total body and urinary excretions. With the data obtained from the mentioned experiments a compartmental model was performed in which the plasma is the central compartment for the distribution of the drug, exchanging with another extraplasmatic compartment and finally the drug being stored in reticulo endothelial system cells. (Author) [pt

  3. Immunomodulating effects of heparin on human B cell proliferation

    International Nuclear Information System (INIS)

    Wasik, Maria; Stepien-Sopniewska, Barbara; Gorski, Andrzej

    1993-01-01

    Recent data indicate that heparin may act as an immunomodulator. In this paper we have analyzed the effect of this agent on human B cell proliferation ''in vitro'' induced by ''S. aureus'' Cowan. The action of heparin is complex, but there was a trend for inhibition of B cell responses obtained from defibrinated but not heparinized blood samples. This suggest that heparin interacts with platelet products (growth factors, cytokines) and the results of such interactions determine the final effect. (author). 6 refs, 4 figs

  4. Heparin and Heparin-Derivatives in Post-Subarachnoid Hemorrhage Brain Injury: A Multimodal Therapy for a Multimodal Disease

    Directory of Open Access Journals (Sweden)

    Erik G. Hayman

    2017-05-01

    Full Text Available Pharmacologic efforts to improve outcomes following aneurysmal subarachnoid hemorrhage (aSAH remain disappointing, likely owing to the complex nature of post-hemorrhage brain injury. Previous work suggests that heparin, due to the multimodal nature of its actions, reduces the incidence of clinical vasospasm and delayed cerebral ischemia that accompany the disease. This narrative review examines how heparin may mitigate the non-vasospastic pathological aspects of aSAH, particularly those related to neuroinflammation. Following a brief review of early brain injury in aSAH and heparin’s general pharmacology, we discuss potential mechanistic roles of heparin therapy in treating post-aSAH inflammatory injury. These roles include reducing ischemia-reperfusion injury, preventing leukocyte extravasation, modulating phagocyte activation, countering oxidative stress, and correcting blood-brain barrier dysfunction. Following a discussion of evidence to support these mechanistic roles, we provide a brief discussion of potential complications of heparin usage in aSAH. Our review suggests that heparin’s use in aSAH is not only safe, but effectively addresses a number of pathologies initiated by aSAH.

  5. Heparin-Induced Thrombocytopenia

    Science.gov (United States)

    ... HIT information card. Early identification of HIT and avoidance of inappropriate heparin therapy can help promote a ... Heart Association is a qualified 501(c)(3) tax-exempt organization. *Red Dress™ DHHS, Go Red™ AHA; ...

  6. Environmental Optimization Using the WAste Reduction Algorithm (WAR)

    Science.gov (United States)

    Traditionally chemical process designs were optimized using purely economic measures such as rate of return. EPA scientists developed the WAste Reduction algorithm (WAR) so that environmental impacts of designs could easily be evaluated. The goal of WAR is to reduce environme...

  7. A spectroscopic study of interaction of cationic dyes with heparin

    Directory of Open Access Journals (Sweden)

    R. Nandini

    2010-01-01

    Full Text Available The interaction of two cationic dyes namely, acridine orange and pinacyanol chloride with an anionic polyelectrolyte, heparin, has been investigated by spectrophotometric method.The polymer induced metachromasy in the dyes resulting in the shift of the absorption maxima of the dyes towards shorter wavelengths. The stability of the complexes formed between acridine orange and heparin was found to be lesser than that formed between pinacyanol chloride and heparin. This fact was further confirmed by reversal studies using alcohols, urea and surfactants. The interaction of acridine orange with heparin has also been investigated fluorimetrically.The interaction parameters revealed that binding between acridine orange and heparin arises due to electrostatic interaction while that between pinacyanol chloride and heparin is found to involve both electrostatic and hydrophobic forces. The effect of the structure of the dye in inducing metachromasy has also been discussed.

  8. Identification of a novel structure in heparin generated by potassium permanganate oxidation

    Science.gov (United States)

    Beccati, Daniela; Roy, Sucharita; Yu, Fei; Gunay, Nur Sibel; Capila, Ishan; Lech, Miroslaw; Linhardt, Robert J.; Venkataraman, Ganesh

    2012-01-01

    The worldwide heparin contamination crisis in 2008 led health authorities to take fundamental steps to better control heparin manufacture, including implementing appropriate analytical and bio-analytical methods to ensure production and release of high quality heparin sodium product. Consequently, there is an increased interest in the identification and structural elucidation of unusually modified structures that may be present in heparin. Our study focuses on the structural elucidation of species that give rise to a signal observed at 2.10 ppm in the N-acetyl region of the 1H NMR spectrum of some pharmaceutical grade heparin preparations. Structural elucidation experiments were carried out using homonuclear (COSY, TOSCY and NOESY) and heteronuclear (HSQC, HSQC-DEPT, HMQC-COSY, HSQC-TOCSY, and HMBC) 2D NMR spectroscopy on both heparin as well as heparin-like model compounds. Our results identify a novel type of oxidative modification of the heparin chain that results from a specific step in the manufacturing process used to prepare heparin. PMID:25147414

  9. Heparin-associated thrombocytopenia: antibody binding specificity to platelet antigens.

    Science.gov (United States)

    Lynch, D M; Howe, S E

    1985-11-01

    Sera from four patients with heparin-associated thrombocytopenia (HAT) were evaluated by a quantitative enzyme-linked immunosorbent assay (ELISA) to detect heparin-dependent serum platelet-bindable immunoglobulin (S-PBIg) and by Western blotting and immunoprecipitation to investigate the specificity of the antibody binding. All HAT sera showed mildly increased S-PBIg (mean, 7.8 fg per platelet; normal, less than 6.0 fg per platelet) to intact target platelets in the ELISA, which was markedly increased in the presence of heparin (mean, 20.9 fg per platelet). This increase was 20-fold greater than normal control sera, which showed a mean differential increase of only 0.5 fg per platelet. Immunoglobulin binding specificity to platelet antigens was investigated using sodium dodecyl sulfate-polyacrylamide gel electrophoresis of platelet lysate with transfer of the platelet fractions onto nitrocellulose strips (Western blotting) and subsequent immunoassay using HAT and normal sera. In the presence of heparin, the four HAT patients demonstrated increased binding of immunoglobulin to platelet antigens of apparent molecular weights of 180, 124, and 82 kd. Radiolabeled heparin when incubated with HAT sera, normal sera, or albumin blanks bound to platelet proteins of the same apparent molecular weights. These observations are consistent with current hypotheses suggesting that HAT antibody is directed to heparin-platelet complexes or, alternatively, that heparin induces conformational change of antigenic sites on the platelet membrane.

  10. Column Reduction of Polynomial Matrices; Some Remarks on the Algorithm of Wolovich

    NARCIS (Netherlands)

    Praagman, C.

    1996-01-01

    Recently an algorithm has been developed for column reduction of polynomial matrices. In a previous report the authors described a Fortran implementation of this algorithm. In this paper we compare the results of that implementation with an implementation of the algorithm originally developed by

  11. Acid-citrate-dextrose compared with heparin in the preparation of in vivo/in vitro technetium-99m red blood cells

    International Nuclear Information System (INIS)

    Porter, W.C.; Dees, S.M.; Freitas, J.E.; Dworkin, H.J.

    1983-01-01

    Red blood cells labeled in vivo/in vitro with Tc-99m (Tc-99m RBC) were prepared in a series of 21 patients and two normal volunteers. In each subject both heparin and acid-citrate-dextrose (ACD) solutions were used to label tandem blood samples. The immediate preinjection binding efficiency (BE) was then determined. In each of the 23 studies, the ACD preparation yielded superior BE. The average BE was 93.47% (+/- 3.78) with ACD and 87.23% (+/- 4.29) with heparin. With the ACD method the effect of carrier Tc-99 may be as great as a 24% reduction in BE observed when initial eluates from long-ingrowth-time generators were used. Improved image quality with minimal renal and urinary-bladder activity results with ACD labeling. It is concluded that the use of ACD results in superior RBC labeling with less nontarget activity relative to heparin and is preferred over heparin for preparing in vivo/in vitro Tc-99m RBC

  12. Quantitative description of thermodynamic and kinetic properties of the platelet factor 4/heparin bonds

    Science.gov (United States)

    Nguyen, Thi-Huong; Greinacher, Andreas; Delcea, Mihaela

    2015-05-01

    Heparin is the most important antithrombotic drug in hospitals. It binds to the endogenous tetrameric protein platelet factor 4 (PF4) forming PF4/heparin complexes which may cause a severe immune-mediated adverse drug reaction, so-called heparin-induced thrombocytopenia (HIT). Although new heparin drugs have been synthesized to reduce such a risk, detailed bond dynamics of the PF4/heparin complexes have not been clearly understood. In this study, single molecule force spectroscopy (SMFS) is utilized to characterize the interaction of PF4 with heparins of defined length (5-, 6-, 8-, 12-, and 16-mers). Analysis of the force-distance curves shows that PF4/heparin binding strength rises with increasing heparin length. In addition, two binding pathways in the PF4/short heparins (=8-mers) are identified. We provide a model for the PF4/heparin complexes in which short heparins bind to one PF4 tetramer, while long heparins bind to two PF4 tetramers. We propose that the interaction between long heparins and PF4s is not only due to charge differences as generally assumed, but also due to hydrophobic interaction between two PF4s which are brought close to each other by long heparin. This complicated interaction induces PF4/heparin complexes more stable than other ligand-receptor interactions. Our results also reveal that the boundary between antigenic and non-antigenic heparins is between 8- and 12-mers. These observations are particularly important to understand processes in which PF4-heparin interactions are involved and to develop new heparin-derived drugs.Heparin is the most important antithrombotic drug in hospitals. It binds to the endogenous tetrameric protein platelet factor 4 (PF4) forming PF4/heparin complexes which may cause a severe immune-mediated adverse drug reaction, so-called heparin-induced thrombocytopenia (HIT). Although new heparin drugs have been synthesized to reduce such a risk, detailed bond dynamics of the PF4/heparin complexes have not been clearly

  13. The Use of Heparin during Endovascular Peripheral Arterial Interventions: A Synopsis

    Directory of Open Access Journals (Sweden)

    Arno M. Wiersema

    2016-01-01

    Full Text Available A large variety exists for many aspects of the use of heparin as periprocedural prophylactic antithrombotics (PPAT during peripheral arterial interventions (PAI. This variation is present, not only within countries, but also between them. Due to a lack of (robust data, no systematic review on the use of heparin during PAI could be justified. A synopsis of all available literature on heparin during PAI describes that heparin is used on technical equipment to reduce the thrombogenicity and in the flushing solution with saline. Heparin could have a cumulative anticoagulant effect when used in combination with ionic contrast medium. No level-1 evidence exists on the use of heparin. A measurement of actual anticoagulation status by means of an activated clotting time should be mandatory.

  14. Analyses of Interactions Between Heparin and the Apical Surface Proteins of Plasmodium falciparum

    Science.gov (United States)

    Kobayashi, Kyousuke; Takano, Ryo; Takemae, Hitoshi; Sugi, Tatsuki; Ishiwa, Akiko; Gong, Haiyan; Recuenco, Frances C.; Iwanaga, Tatsuya; Horimoto, Taisuke; Akashi, Hiroomi; Kato, Kentaro

    2013-11-01

    Heparin, a sulfated glycoconjugate, reportedly inhibits the blood-stage growth of the malaria parasite Plasmodium falciparum. Elucidation of the inhibitory mechanism is valuable for developing novel invasion-blocking treatments based on heparin. Merozoite surface protein 1 has been reported as a candidate target of heparin; however, to better understand the molecular mechanisms involved, we characterized the molecules that bind to heparin during merozoite invasion. Here, we show that heparin binds only at the apical tip of the merozoite surface and that multiple heparin-binding proteins localize preferentially in the apical organelles. To identify heparin-binding proteins, parasite proteins were fractionated by means of heparin affinity chromatography and subjected to immunoblot analysis with ligand-specific antibodies. All tested members of the Duffy and reticulocyte binding-like families bound to heparin with diverse affinities. These findings suggest that heparin masks the apical surface of merozoites and blocks interaction with the erythrocyte membrane after initial attachment.

  15. Use of heparin in the investigation of obscure gastrointestinal bleeding

    International Nuclear Information System (INIS)

    Mernagh, J.R.; O'Donovan, N.; Somers, S.; Gill, G.; Sridhar, S.

    2001-01-01

    To determine if the administration of heparin improves the predictive value of angiography in the investigation of obscure gastrointestinal (GI) bleeding. 18 patients with a history of chronic GI bleeding were investigated with angiography. For 6 patients, the cause of GI bleeding was established with angiography; the 12 patients who had negative results were given heparin for 24 h and were reassessed with angiography. After heparin administration, the source of GI bleeding was determined with angiography for 6 of the remaining 12 patients. Thus, heparinization increased diagnostic yield from 33% (6 of 18) to 67% (12 of 18). No significant complications, such as uncontrolled GI bleeding, occurred. Heparinization improves the diagnostic yield of angiography when obscure GI bleeding is being investigated. (author)

  16. Qualitative and quantitative analysis of heparin and low molecular weight heparins using size exclusion chromatography with multiple angle laser scattering/refractive index and inductively coupled plasma/mass spectrometry detectors.

    Science.gov (United States)

    Ouyang, Yilan; Zeng, Yangyang; Yi, Lin; Tang, Hong; Li, Duxin; Linhardt, Robert J; Zhang, Zhenqing

    2017-11-03

    Heparin, a highly sulfated glycosaminoglycan, has been used as a clinical anticoagulant over 80 years. Low molecular weight heparins (LMWHs), heparins partially depolymerized using different processes, are widely used as clinical anticoagulants. Qualitative molecular weight (MW) and quantitative mass content analysis are two important factors that contribute to LMWH quality control. Size exclusion chromatography (SEC), relying on multiple angle laser scattering (MALS)/refractive index (RI) detectors, has been developed for accurate analysis of heparin MW in the absence of standards. However, the cations, which ion-pair with the anionic polysaccharide chains of heparin and LMWHs, had not been considered in previous reports. In this study, SEC with MALS/RI and inductively coupled plasma/mass spectrometry detectors were used in a comprehensive analytical approach taking both anionic polysaccharide and ion-paired cations heparin products. This approach was also applied to quantitative analysis of heparin and LMWHs. Full profiles of MWs and mass recoveries for three commercial heparin/LMWH products, heparin sodium, enoxaparin sodium and nadroparin calcium, were obtained and all showed higher MWs than previously reported. This important improvement more precisely characterized the MW properties of heparin/LMWHs and potentially many other anionic polysaccharides. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. The clinical significance and risk factors of anti-platelet factor 4/heparin antibody on maintenance hemodialysis patients: a two-year prospective follow-up.

    Directory of Open Access Journals (Sweden)

    Delong Zhao

    Full Text Available BACKGROUND: Heparin-induced thrombocytopenia is an immune response mediated by anti-PF4/heparin antibody, which is clinically characterized by thrombocytopenia and thromboembolic events. In this study, a prospective and multi-center clinical investigation 1 determined the positive rate of anti-PF4/heparin antibody in maintenance hemodialysis patients in China, 2 identified the related risk factors, and 3 further explored the effect of the anti-PF4/heparin antibody on bleeding, thromboembolic events, and risk of death in the patients. METHODS: The serum anti-PF4/heparin antibody was measured in 661 patients from nine hemodialysis centers, detected by IgG-specific ELISA and followed by confirmation with excess heparin. Risk factors of these patients were analyzed. Based on a two-year follow-up, the association between the anti-PF4/heparin antibody and bleeding, thromboembolic events, and risk of death in the patients was investigated. RESULTS: 1 The positivity rate of the anti-PF4/heparin antibody in maintenance hemodialysis patients was 5.6%. With diabetes as an independent risk factor, the positivity rate of the anti-PF4/heparin antibody decreased in the patients undergoing weekly dialyses ≥3 times. 2 The positivity rate of the anti-PF4/heparin antibody was not related to the occurrence of clinical thromboembolic events and was not a risk factor for death within two years in maintenance hemodialysis patients. 3 Negativity for the anti-PF4/heparin antibody combined with a reduction of the platelet count or combined with the administration of antiplatelet drugs yielded a significant increase in bleeding events. However, the composite determination of the anti-PF4/heparin antibody and thrombocytopenia, as well as the administration of antiplatelet drugs, was not predictive for the risk of thromboembolic events in the maintenance hemodialysis patients. CONCLUSIONS: A single detection of the anti-PF4/heparin antibody did not predict the occurrence

  18. Parameter-free Network Sparsification and Data Reduction by Minimal Algorithmic Information Loss

    KAUST Repository

    Zenil, Hector

    2018-02-16

    The study of large and complex datasets, or big data, organized as networks has emerged as one of the central challenges in most areas of science and technology. Cellular and molecular networks in biology is one of the prime examples. Henceforth, a number of techniques for data dimensionality reduction, especially in the context of networks, have been developed. Yet, current techniques require a predefined metric upon which to minimize the data size. Here we introduce a family of parameter-free algorithms based on (algorithmic) information theory that are designed to minimize the loss of any (enumerable computable) property contributing to the object\\'s algorithmic content and thus important to preserve in a process of data dimension reduction when forcing the algorithm to delete first the least important features. Being independent of any particular criterion, they are universal in a fundamental mathematical sense. Using suboptimal approximations of efficient (polynomial) estimations we demonstrate how to preserve network properties outperforming other (leading) algorithms for network dimension reduction. Our method preserves all graph-theoretic indices measured, ranging from degree distribution, clustering-coefficient, edge betweenness, and degree and eigenvector centralities. We conclude and demonstrate numerically that our parameter-free, Minimal Information Loss Sparsification (MILS) method is robust, has the potential to maximize the preservation of all recursively enumerable features in data and networks, and achieves equal to significantly better results than other data reduction and network sparsification methods.

  19. Investigation of the heparin-thrombin interaction by dynamic force spectroscopy.

    Science.gov (United States)

    Wang, Congzhou; Jin, Yingzi; Desai, Umesh R; Yadavalli, Vamsi K

    2015-06-01

    The interaction between heparin and thrombin is a vital step in the blood (anti)coagulation process. Unraveling the molecular basis of the interactions is therefore extremely important in understanding the mechanisms of this complex biological process. In this study, we use a combination of an efficient thiolation chemistry of heparin, a self-assembled monolayer-based single molecule platform, and a dynamic force spectroscopy to provide new insights into the heparin-thrombin interaction from an energy viewpoint at the molecular scale. Well-separated single molecules of heparin covalently attached to mixed self-assembled monolayers are demonstrated, whereby interaction forces with thrombin can be measured via atomic force microscopy-based spectroscopy. Further these interactions are studied at different loading rates and salt concentrations to directly obtain kinetic parameters. An increase in the loading rate shows a higher interaction force between the heparin and thrombin, which can be directly linked to the kinetic dissociation rate constant (koff). The stability of the heparin/thrombin complex decreased with increasing NaCl concentration such that the off-rate was found to be driven primarily by non-ionic forces. These results contribute to understanding the role of specific and nonspecific forces that drive heparin-thrombin interactions under applied force or flow conditions. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Current Trends in Heparin Use During Arterial Vascular Interventional Radiology

    International Nuclear Information System (INIS)

    Durran, Alexandra C.; Watts, Christopher

    2012-01-01

    Purpose: This study was designed to assess the current use of heparinized saline and bolus doses of heparin in non-neurological interventional radiology and to determine whether consensus could be reached to produce guidance for heparin use during arterial vascular intervention. Methods: An interactive electronic questionnaire was distributed to members of the British Society of Interventional Radiology regarding their current practice in the use, dosage, and timing of heparin boluses and heparinized flushing solutions.ResultsA total of 108 completed questionnaires were received. More than 80% of respondents used heparinized saline with varying concentrations; the most prevalent was 1,000 IU/l (international units of heparin per liter) and 5,000 IU/l. Fifty-one percent of interventionalists use 3,000 IU as their standard bolus dose; however, the respondents were split regarding the timing of bolus dose with ∼60% administering it after arterial access is obtained and 40% after crossing the lesion. There was no consensus on altering dose according to body weight, and only 4% monitored clotting parameters. Conclusions: There seems to be some coherence among practicing interventionalists regarding heparin administration. We hypothesize that heparinized saline should be used at a recognized standard concentration of 1,000 IU/l as a flushing concentration in all arterial vascular interventions and that 3,000 IU bolus is considered the standard dose for straightforward therapeutic procedures and 5000 IU for complex, crural, and endovascular aneurysm repair work. The bolus should be given after arterial access is obtained to allow time for optimal anticoagulation to be achieved by the time of active intervention and stenting. Further research into clotting abnormalities following such interventional procedures would be an interesting quantifiable follow-up to this initial survey of opinions and practice.

  1. The intracellular uptake and protracted release of exogenous heparins by cultured endothelial cells

    International Nuclear Information System (INIS)

    Hiebert, L.M.; McDuffie, N.M.

    1989-01-01

    Heparins from bovine or porcine sources were fed in media for 48 hrs to cultured porcine aortic and human umbilical vein endothelial cells. Heparin was found in pericellular and cellular fractions after extraction by chemical methods and 125 I radiolabelled heparins were recovered when radiolabelled heparin was included in the feed. Even after washing and media changes heparin was detected in media and cell fractions up to 6 days post feeding. Metachromatic vacuoles within cells were demonstrated histologically up to 7 days post feeding after staining with toluidine blue. This is the first report of protracted internalization of exogenous heparin by cultured endothelial cells with concurrent prolonged release of the heparin to the media. This clearly demonstrates that the endothelium plays an important role in the distribution and metabolism of heparin

  2. Comparison of established and novel purity tests for the quality control of heparin by means of a set of 177 heparin samples.

    Science.gov (United States)

    Alban, Susanne; Lühn, Susanne; Schiemann, Simone; Beyer, Tanja; Norwig, Jochen; Schilling, Claudia; Rädler, Oliver; Wolf, Bernhard; Matz, Magnus; Baumann, Knut; Holzgrabe, Ulrike

    2011-01-01

    The widespread occurrence of heparin contaminated with oversulfated chrondroitin sulfate (OSCS) in 2008 initiated a comprehensive revision process of the Pharmacopoeial heparin monographs and stimulated research in analytical techniques for the quality control of heparin. Here, a set of 177 heparin samples from the market in 2008 as well as pure heparin sodium spiked with defined amounts of OSCS and DS were used to evaluate established and novel methods for the quality control of heparin. Besides (1)H nuclear magnetic resonance spectroscopy (NMR), the assessment included two further spectroscopic methods, i.e., attenuated total reflection-infrared spectroscopy (ATR-IR) and Raman spectroscopy, three coagulation assays, i.e., activated partial thromboplastin time (aPTT) performed with both sheep and human plasma and the prothrombin time (PT), and finally two novel purity assays, each consisting of an incubation step with heparinase I followed by either a fluorescence measurement (Inc-PolyH-assay) or by a chromogenic aXa-assay (Inc-aXa-assay). NMR was shown to allow not only sensitive detection, but also quantification of OSCS by using the peak-height method and a response factor determined by calibration. Chemometric evaluation of the NMR, ATR-IR, and Raman spectra by statistical classification techniques turned out to be best with NMR spectra concerning the detection of OSCS. The validity of the aPTT, the current EP assay, could be considerably improved by replacing the sheep plasma by human plasma. In this way, most of the contaminated heparin samples did not meet the novel potency limit of 180 IU/mg. However, also more than 50% of the uncontaminated samples had interpretation of the results.

  3. Heparin: The Silver Bullet of Aneurysmal Subarachnoid Hemorrhage?

    Directory of Open Access Journals (Sweden)

    Nicolas K. Khattar

    2018-03-01

    Full Text Available Various neurological diseases have recently been associated with neuroinflammation and worsening outcomes. Subarachnoid hemorrhage has been shown to generate a potent neuroinflammatory response. Heparin is a potential effective anti-inflammatory agent to prevent initial injury as well as delayed neurological decline. Different mechanisms of action for heparin have been proposed including, but not limited to the binding and neutralization of oxyhemoglobin, decreased transcription and signal transduction of endothelin-1, inhibition of binding to vessel wall selectins and vascular leakage into the subarachnoid space as well as direct binding and neutralization of inflammatory molecules. With a reasonably safe side-effect profile, heparin has shown significant promise in small series in human studies of aneurysmal subarachnoid hemorrhage in decreasing both initial and delayed neurological injury. Further studies are needed to validate various neuroprotective features of heparin in subarachnoid hemorrhage as well as other disease states.

  4. Image noise reduction algorithm for digital subtraction angiography: clinical results.

    Science.gov (United States)

    Söderman, Michael; Holmin, Staffan; Andersson, Tommy; Palmgren, Charlotta; Babic, Draženko; Hoornaert, Bart

    2013-11-01

    To test the hypothesis that an image noise reduction algorithm designed for digital subtraction angiography (DSA) in interventional neuroradiology enables a reduction in the patient entrance dose by a factor of 4 while maintaining image quality. This clinical prospective study was approved by the local ethics committee, and all 20 adult patients provided informed consent. DSA was performed with the default reference DSA program, a quarter-dose DSA program with modified acquisition parameters (to reduce patient radiation dose exposure), and a real-time noise-reduction algorithm. Two consecutive biplane DSA data sets were acquired in each patient. The dose-area product (DAP) was calculated for each image and compared. A randomized, blinded, offline reading study was conducted to show noninferiority of the quarter-dose image sets. Overall, 40 samples per treatment group were necessary to acquire 80% power, which was calculated by using a one-sided α level of 2.5%. The mean DAP with the quarter-dose program was 25.3% ± 0.8 of that with the reference program. The median overall image quality scores with the reference program were 9, 13, and 12 for readers 1, 2, and 3, respectively. These scores increased slightly to 12, 15, and 12, respectively, with the quarter-dose program imaging chain. In DSA, a change in technique factors combined with a real-time noise-reduction algorithm will reduce the patient entrance dose by 75%, without a loss of image quality. RSNA, 2013

  5. A Turn-on Fluorescence Sensor for Heparin Detection Based on a Release of Taiwan Cobra Cardiotoxin from a DNA Aptamer or Adenosine-Based Molecular Beacon.

    Science.gov (United States)

    Shi, Yi-Jun; Wang, Liang-Jun; Lee, Yuan-Chin; Huang, Chia-Hui; Hu, Wan-Ping; Chang, Long-Sen

    2018-02-19

    This study presents two sensitive fluorescent assays for sensing heparin on the basis of the electrostatic interaction between heparin and Naja naja atra cardiotoxin 3 (CTX3). Owing to CTX3-induced folded structure of an adenosine-based molecular beacon (MB) or a DNA aptamer against CTX3, a reduction in the fluorescent signal of the aptamer or MB 5'-end labeled with carboxyfluorescein (FAM) and 3'-end labeled with 4-([4-(dimethylamino)phenyl]azo)-benzoic acid (DABCYL) was observed upon the addition of CTX3. The presence of heparin and formation of the CTX3-heparin complex caused CTX3 detachment from the MB or aptamer, and restoration of FAM fluorescence of the 5'-FAM-and-3'-DABCYL-labeled MB and aptamer was subsequently noted. Moreover, the detection of heparin with these CTX3-aptamer and CTX3-MB sensors showed high sensitivity and selectivity toward heparin over chondroitin sulfate and hyaluronic acid regardless of the presence of plasma. The limit of detection for heparin in plasma was determined to be 16 ng/mL and 15 ng/mL, respectively, at a signal-to-noise ratio of 3. This study validates the practical utility of the CTX3-aptamer and CTX3-MB systems for determining the concentration of heparin in a biological matrix.

  6. Community nurse resource implications for a change in heparin prophylaxis policy

    Directory of Open Access Journals (Sweden)

    Parker Martyn J.

    2015-01-01

    Full Text Available Introduction: A review was undertaken for a consecutive series of hip fracture patients for the year before and then after a change in low dose heparin prophylaxis policy. Patients and methods: For the first year heparin was administered in hospital for a maximum of 14 days only. Patients sent home before this time were not discharged taking heparin. For the second year heparin was administered as recommended by NICE guidelines for 28 days from admission regardless of whether the patient was discharged. Results: For the first year 486 patients were treated with a mean of 10.4 doses of heparin per patient. For the second year 465 patients were treated with a mean of 24.3 doses per patient. In total an extra 6,464 doses of heparin were administered. 33.8% of patients were unable to administer their heparin at home therefore a district nurse administered 2,284 of these doses of subcutaneous heparin at the patient’s home. The increased cost associated with the change in policy was estimated to be £161 per patient, with over 90% of this increase being incurred by the district nurse expense. If applied nationally for the England, using extended heparin prophylaxis for hip fracture patients would cost in excess of 12 million pounds each year. Conclusion: Whilst the necessity for and duration of thromboembolic prophylaxis for these patients remains undetermined, there is a need to re-evaluate the cost effectiveness of the current recommendations for hip fracture patients.

  7. Influence of spacer length on heparin coupling efficiency and fibrinogen adsorption of modified titanium surfaces

    Directory of Open Access Journals (Sweden)

    Gbureck Uwe

    2007-07-01

    Full Text Available Abstract Background Chemical bonding of the drug onto surfaces by means of spacer molecules is accompanied with a reduction of the biological activity of the drug due to a constricted mobility since normally only short spacer molecule like aminopropyltrimethoxysilane (APMS are used for drug coupling. This work aimed to study covalent attachment of heparin to titanium(oxide surfaces by varying the length of the silane coupling agent, which should affect the biological potency of the drug due to a higher mobility with longer spacer chains. Methods Covalent attachment of heparin to titanium metal and TiO2 powder was carried out using the coupling agents 3-(Trimethoxysilyl-propylamine (APMS, N- [3-(Trimethoxysilylpropyl]ethylenediamine (Diamino-APMS and N1- [3-(Trimethoxy-silyl-propyl]diethylenetriamine (Triamino-APMS. The amount of bound coupling agent and heparin was quantified photometrically by the ninhydrin reaction and the tolidine-blue test. The biological potency of heparin was determined photometrically by the chromogenic substrate Chromozym TH and fibrinogen adsorption to the modified surfaces was researched using the QCM-D (Quartz Crystal Microbalance with Dissipation Monitoring technique. Results Zeta-potential measurements confirmed the successful coupling reaction; the potential of the unmodified anatase surface (approx. -26 mV shifted into the positive range (> + 40 mV after silanisation. Binding of heparin results in a strongly negatively charged surface with zeta-potentials of approx. -39 mV. The retaining biological activity of heparin was highest for the spacer molecule Triamino-APMS. QCM-D measurements showed a lower viscosity for adsorbed fibrinogen films on heparinised surfaces by means of Triamino-APMS. Conclusion The remaining activity of heparin was found to be highest for the covalent attachment with Triamino-APMS as coupling agent due to the long chain of this spacer molecule and therefore the highest mobility of the drug

  8. Heparin conjugated quantum dots for in vitro imaging applications.

    Science.gov (United States)

    Maguire, Ciaran Manus; Mahfoud, Omar Kazem; Rakovich, Tatsiana; Gerard, Valerie Anne; Prina-Mello, Adriele; Gun'ko, Yurii; Volkov, Yuri

    2014-11-01

    In this work heparin-gelatine multi-layered cadmium telluride quantum dots (QDgel/hep) were synthesised using a novel 'one-pot' method. The QDs produced were characterised using various spectroscopic and physiochemical techniques. Suitable QDs were then selected and compared to thioglycolic acid stabilised quantum dots (QDTGA) and gelatine coated quantum dots (QDgel) for utilisation in in vitro imaging experiments on live and fixed permeabilised THP-1, A549 and Caco-2 cell lines. Exposure of live THP-1 cells to QDgel/hep resulted in localisation of the QDs to the nucleus of the cells. QDgel/hep show affinity for the nuclear compartment of fixed permeabilised THP-1 and A549 cells but remain confined to cytoplasm of fixed permeabilised Caco-2 cells. It is postulated that heparin binding to the CD11b receptor facilitates the internalisation of the QDs into the nucleus of THP-1 cells. In addition, the heparin layer may reduce the unfavourable thrombogenic nature of quantum dots observed in vivo. In this study, heparin conjugated quantum dots were found to have superior imaging properties compared to its native counterparts. The authors postulate that heparin binding to the CD11b receptor facilitates QD internalization to the nucleus, and the heparin layer may reduce the in vivo thrombogenic properties of quantum dots. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. Bioinspired Heparin Nanosponge Prepared by Photo-crosslinking for Controlled Release of Growth Factors

    DEFF Research Database (Denmark)

    Choi, Won Il; Sahu, Abhishek; Vilos, Cristian

    2017-01-01

    to overcome these limitations. Herein, we have developed a thermosensitive heparin nanosponge (Hep-NS) by a one step photopolymerization reaction between diacrylated pluronic and thiolated heparin molecules. The amount of heparin in Hep-NS was precisely controlled by varying the heparin amount in the reaction...

  10. Preparation and in vitro evaluation of heparin-loaded polymeric nanoparticles.

    Science.gov (United States)

    Jiao, Y Y; Ubrich, N; Marchand-Arvier, M; Vigneron, C; Hoffman, M; Maincent, P

    2001-01-01

    Nanoparticles of a highly soluble macromolecular drug, heparin, were formulated with two biodegradable polymers (poly-E-caprolactone [PCL] and poly (D, L-lactic-co-glycolic-acid) 50/50 [PLAGA]) and two nonbiodegradable positively charged polymers (Eudragit RS and RL) by the double emulsion and solvent evaporation method, using a high-pressure homogenization device. The encapsulation efficiency and heparin release profiles were studied as a function of the type of polymers employed (alone or in combination) and the concentration of heparin. Optimal encapsulation efficiency was observed when 5000 IU of heparin were incorporated in the first emulsion. High drug entrapment efficiency was observed in both Eudragit RS and RL nanoparticles (60% and 98%, respectively), compared with PLAGA and PCL nanoparticles (PLAGA increased the encapsulation efficiency compared with these two biodegradable polymers used alone; however, the in vitro drug release was not modified and remained low. On the other hand, the addition of esterase to the dissolution medium resulted in a significant increase in heparin release. The in vitro biological activity of released heparin, evaluated by measuring the anti-Xa activity by a colorimetric assay, was conserved after the encapsulation process.

  11. Comparison of order reduction algorithms for application to electrical networks

    Directory of Open Access Journals (Sweden)

    Lj. Radić-Weissenfeld

    2009-05-01

    Full Text Available This paper addresses issues related to the minimization of the computational burden in terms of both memory and speed during the simulation of electrical models. In order to achieve a simple and computational fast model the order reduction of its reducible part is proposed. In this paper the overview of the order reduction algorithms and their application are discussed.

  12. The regulatory role of heparin on c-Met signaling in hepatocellular carcinoma cells.

    Science.gov (United States)

    İşcan, Evin; Güneş, Aysim; Korhan, Peyda; Yılmaz, Yeliz; Erdal, Esra; Atabey, Neşe

    2017-06-01

    The role of heparin as an anticoagulant is well defined; however, its role in tumorigenesis and tumor progression is not clear yet. Some studies have shown that anticoagulant treatment in cancer patients improve overall survival, however, recent clinical trials have not shown a survival benefit in cancer patients receiving heparin treatment. In our previous studies we have shown the inhibitory effects of heparin on Hepatocyte Growth Factor (HGF)-induced invasion and migration in hepatocellular carcinoma (HCC) cells. In this study, we showed the differential effects of heparin on the behaviors of HCC cells based on the presence or absence of HGF. In the absence of HGF, heparin activated HGF/c-Met signaling and promoted motility and invasion in HCC cells. Heparin treatment led to c-Met receptor dimerization and activated c-Met signaling in an HGF independent manner. Heparin-induced c-Met activation increased migration and invasion through ERK1/2, early growth response factor 1 (EGR1) and Matrix Metalloproteinases (MMP) axis. Interestingly, heparin modestly decreased the proliferation of HCC cells by inhibiting activatory phosphorylation of Akt. The inhibition of c-Met signaling reversed heparin-induced increase in motility and invasion and, proliferation inhibition. Our study provides a new perspective into the role of heparin on c-Met signaling in HCC.

  13. Effects of the repeated administration of adenosine and heparin on myocardial perfusion in patients with chronic stable angina pectoris.

    Science.gov (United States)

    Barron, H V; Sciammarella, M G; Lenihan, K; Michaels, A D; Botvinick, E H

    2000-01-01

    The mechanism by which ischemia stimulates angiogenesis is unknown. Adenosine is released during myocardial ischemia and may be a mediator of this process. Experimental data suggest that heparin may enhance this effect. The purpose of this open-labeled, placebo-controlled trial was to determine whether repeated intravenous administration of adenosine and heparin could mimic physiologic angiogenesis and reduce the amount of exercise-induced myocardial ischemia in patients with coronary artery disease. Subjects with chronic stable angina refractory to conventional medical therapy and not suitable for revascularization received either adenosine (140 microg/kg/min for 6 minutes) and heparin (10,000 U bolus), (n = 14), or placebo, (n = 7) daily for 10 days. All patients underwent baseline and follow-up exercise testing with thallium-201 single-photon emission computed tomography myocardial perfusion imaging. A semiquantitative assessment of the extent and severity of the perfusion abnormalities was calculated by 2 blinded investigators. There was no significant change in exercise duration or in the peak heart rate systolic blood pressure product associated with adenosine and heparin compared with placebo treatment. There was, however, a 9% reduction in the extent (60.6 +/- 4.0 vs 54.9 +/- 4.1, p = 0.03) and a 14% improvement in severity (41.5 +/- 3.2 vs 35.7 +/- 2.9, p = 0.01) of the myocardial perfusion abnormalities seen in patients who received adenosine and heparin compared with placebo. Thus, in this pilot study, repeated administration of adenosine and heparin reduced the amount of exercise-induced ischemia in patients with chronic stable angina refractory to conventional treatment.

  14. DEGRADATION AND INTRAHEPATIC COMPATIBILITY OF ALBUMIN-HEPARIN CONJUGATE MICROSPHERES

    NARCIS (Netherlands)

    CREMERS, HFM; WOLF, RFE; BLAAUW, EH; SCHAKENRAAD, JM; LAM, KH; NIEUWENHUIS, P; VERRIJK, R; KWON, G; BAE, YH; KIM, SW; FEIJEN, J

    The in vitro degradation properties of glutaraldehyde cross-linked albumin and albumin-heparin conjugate microspheres (AMS and AHCMS respectively) were evaluated using light microscopy, turbidity measurements and heparin release determinations, showing that the microspheres are degraded by

  15. In vitro anticoagulation monitoring of low-molecular-weight heparin

    Institute of Scientific and Technical Information of China (English)

    WANG Jian-qi; SHI Xu-bo; YANG Jin-gang; HU Da-yi

    2009-01-01

    Background Although low-molecular-weight heparin has replaced unfractionated heparin to become the primary anticoagulation drug for treatment of acute coronary syndrome, there is no convenient bedside monitoring method. We explored the best laboratory monitoring method of low-molecular-weight heparins (enoxapadn, dalteparin, and nadroparin) by use of the Sonoclot coagulation analyzer to monitor the activated clotting time.Methods Atotal of 20 healthy volunteers were selected and 15 ml of fasting venous blood samples were collected and incubated. Four coagulants, kaolin, diatomite, glass bead, and magnetic stick, were used to determine the activated clotting time of the low-molecular-weight heparins at different in vitro anti-Xa factor concentrations. A correlation analysis was made to obtain the regression equation. The activated clotting time of the different low-molecular-weight heparins with the same anti-Xa factor concentration was monitored when the coagulant glass beads were applied. Results The activated clotting time measured using the glass beads, diatomite, kaolin, and magnetic stick showed a linear correlation with the concentration of nadroparin (r= 0.964, 0.966, 0.970, and 0.947, respectively). The regression equation showed that the linear slopes of different coagulants were significantly different (glass beads 230.03 s/IU,diatomite 89.91 s/IU, kaolin 50.87 s/IU, magnetic stick could not be calculated). When the concentration of the anti-Xa factor was the same for different low-molecular-weight heparins, the measured activated clotting time was different after the application of the glass bead coagulant.Conclusions The glass bead coagulant is most feasible for monitoring the in vitro anticoagulation activity of nadroparin.The different effects of different low-molecular-weight heparins on the activated clotting time may be related to the different anti-Ila activities.

  16. The Support Reduction Algorithm for Computing Non-Parametric Function Estimates in Mixture Models

    OpenAIRE

    GROENEBOOM, PIET; JONGBLOED, GEURT; WELLNER, JON A.

    2008-01-01

    In this paper, we study an algorithm (which we call the support reduction algorithm) that can be used to compute non-parametric M-estimators in mixture models. The algorithm is compared with natural competitors in the context of convex regression and the ‘Aspect problem’ in quantum physics.

  17. Increased accuracy in heparin and protamine administration decreases bleeding

    DEFF Research Database (Denmark)

    Runge, Marx; Møller, Christian H; Steinbrüchel, Daniel A

    2009-01-01

    Three to 5 percent of the patients undergoing cardiac surgery are reoperated because of bleeding. When a surgical cause can be excluded, heparin/protamine mismatch may be considered. Insufficient reversal of heparin and overdosing of protamine may cause postoperative bleeding. The purpose......). A reduced number of patients needed blood transfusions in the RxDx group, although this was not statistically significant (19% vs. 38%, respectively; p = .13). Initial heparin dose was significantly reduced in the RxDx group (250 mg; range, 100-375 mg) compared with the control group (300 mg; range, 200...

  18. Prophylaxis of postoperative thromboembolism with low molecular weight heparins

    DEFF Research Database (Denmark)

    Jørgensen, L N; Wille-Jørgensen, P; Hauch, O

    1993-01-01

    To evaluate the thromboprophylactic use of low molecular weight heparins (LMWHs), publications from 27 orthopaedic trials and 35 studies of patients undergoing general or gynaecological surgery were scrutinized and subjected to a partial meta-analysis. In orthopaedic surgery, LMWHs were superior...... to placebo or dextran and at least as efficient as unfractionated heparin in the prevention of deep vein thrombosis (DVT). Compared with unfractionated heparin, one of the LMWH preparations significantly reduced the total incidence of DVT. The rate of non-fatal pulmonary embolism was 0.49 per cent...

  19. Reduction rules-based search algorithm for opportunistic replacement strategy of multiple life-limited parts

    Directory of Open Access Journals (Sweden)

    Xuyun FU

    2018-01-01

    Full Text Available The opportunistic replacement of multiple Life-Limited Parts (LLPs is a problem widely existing in industry. The replacement strategy of LLPs has a great impact on the total maintenance cost to a lot of equipment. This article focuses on finding a quick and effective algorithm for this problem. To improve the algorithm efficiency, six reduction rules are suggested from the perspectives of solution feasibility, determination of the replacement of LLPs, determination of the maintenance occasion and solution optimality. Based on these six reduction rules, a search algorithm is proposed. This search algorithm can identify one or several optimal solutions. A numerical experiment shows that these six reduction rules are effective, and the time consumed by the algorithm is less than 38 s if the total life of equipment is shorter than 55000 and the number of LLPs is less than 11. A specific case shows that the algorithm can obtain optimal solutions which are much better than the result of the traditional method in 10 s, and it can provide support for determining to-be-replaced LLPs when determining the maintenance workscope of an aircraft engine. Therefore, the algorithm is applicable to engineering applications concerning opportunistic replacement of multiple LLPs in aircraft engines.

  20. Heparin induced thrombocytopenia type ii and myocardial infarction: Two case reports

    Directory of Open Access Journals (Sweden)

    Antonijević Nebojša

    2004-01-01

    Full Text Available Heparin-induced thrombocytopenia (HIT type II is an acquired thrombophylic state and life-threatening immune complication of a heparin treatment mainly clinically manifested by marked thrombocytopenia, frequently by arterial and venous thrombosis, and sometimes by skin changes. Functional assay as heparin aggregation test and 14C-serotonin release assays are used in diagnostics as well as antigen assays of which detection tests for heparin-platelet factor 4 antibodies are most frequently used. Considering the fact that there is no single reliable assays for HIT II detection available, sometimes it is necessary to combine both of the above-mentioned types of assays. We present the case of a 57-year-old patient with an acute anterior myocardial infarction with cardiac insufficiency of III and IV degree according to Killip, recurrent ventricular fibrillation and diabetes mellitus type II developing thrombocytopenia to 37x10 9/l accompanied with typical skin changes. The diagnosis was confirmed by the heparin aggregation test. The second patient aged 70 undergoing the treatment for anteroseptal myocardial infarction and reinfarction of the inferior wall complicated by a cardiogenic shock and acute right bundle branch block developed thrombocytopenia 59x10 9/I on the third day of the heparin therapy, with the remark that he had received a heparin therapy during the first infarction as well. Antibodies against heparin-platelet factor 4 were detected by particle gel ID-HPF4 immunoassay. In both patients, the disease had a lethal outcome despite all then available therapeutic measures applied. Further on we discuss advantages of certain types of tests, a therapy doctrine, need for urgent therapeutic measures, inclusive of the administration of anitithrombins, avoidance of harmful procedures like low-molecular-weight heparins administration and prophylactic platelet transfusion as well as preventive measures.

  1. Heparin induces an accumulation of atherogenic lipoproteins during hemodialysis in normolipidemic end-stage renal disease patients.

    Science.gov (United States)

    Barbagallo, Carlo M; Noto, Davide; Cefalù, Angelo B; Ganci, Antonia; Giammarresi, Carlo; Panno, Donata; Cusumano, Gaspare; Greco, Massimiliano; Di Gaudio, Francesca; Averna, Maurizio R

    2015-07-01

    Dyslipidemias may account for the excess of cardiovascular mortality in end-stage renal disease (ESRD). Lipoprotein studies in ESRD patients are usually relative to prehemodialysis samples even if significative changes may occur after dialysis. In this study, we aimed to investigate the effects of ESRD on triglyceride-rich lipoproteins (TRL) subpopulations distribution and acute change following hemodialytic procedures, including the relative contribution of heparin administration. We selected a group of normolipidemic male middle-aged ESRD patients free of any concomitant disease affecting lipoprotein remnant metabolism compared with controls. We separated TRL subfractions according to density and apoE content and evaluated the changes of these particles after hemodialytic procedures with or without heparin. ESRD subjects had higher TRL subfractions, with the exception of apoE-rich particles, lower high-density lipoprotein (HDL) largest subclasses, and a smaller low-density lipoprotein peak particle size than controls. After a hemodialytic standard procedure with heparin, we demonstrated a significant reduction of triglyceride, an increase of HDL-cholesterol levels, and a raise of small very-low-density lipoprotein, intermediate-density lipoproteins (IDL), apoE-rich particles, and non-HDL-cholesterol levels. When hemodialysis was performed without heparin, no significant changes were observed. In the absence of concomitant hyperlipidemic triggers, ESRD patients show significant lipoprotein abnormalities before dialysis, but without any increased remnant particles concentrations. We speculate that hemodialysis, in particular heparin administration during this procedure, leads to a massive atherogenic TRLs production because of the acute stimulation of the dysfunctional lipolytic system not followed by an efficient removal, determining a recurrent lipoprotein remnant accumulation. © 2014 International Society for Hemodialysis.

  2. Heparin release from thermosensitive polymer coatings: in vivo studies

    NARCIS (Netherlands)

    Gutowska, Anna; Bae, You Han; Jacobs, Harvey; Mohammad, Fazal; Mix, Donald; Feijen, Jan; Kim, Sung Wan

    1995-01-01

    Biomer/poly(N-isopropylacrylamide)/[poly(NiPAAm)] thermosensitive polymer blends were prepared and their application as heparin-releasing polymer coatings for the prevention of surface-induced thrombosis was examined. The advantage of using poly(NiPAAm)-based coatings as heparin-releasing polymers

  3. Poly(vinyl alcohol)-heparin hydrogels as sensor catheter membranes

    NARCIS (Netherlands)

    Brinkman, E.; van der Does, L.; Bantjes, A.

    1991-01-01

    Poly(vinyl alcohol)-heparin hydrogels with varying water content were synthesized for use as sensor catheter membranes. Films were cast from aqueous mixtures of poly(viny) alcohol) (PVA), a photosensitive cross-linker p-diazonium diphenyl amine polymer (PA), glutaraldehyde (GA) and heparin. After

  4. From Farm to Pharma: An Overview of Industrial Heparin Manufacturing Methods.

    Science.gov (United States)

    van der Meer, Jan-Ytzen; Kellenbach, Edwin; van den Bos, Leendert J

    2017-06-21

    The purification of heparin from offal is an old industrial process for which commercial recipes date back to 1922. Although chemical, chemoenzymatic, and biotechnological alternatives for this production method have been published in the academic literature, animal-tissue is still the sole source for commercial heparin production in industry. Heparin purification methods are closely guarded industrial secrets which are not available to the general (scientific) public. However by reviewing the academic and patent literature, we aim to provide a comprehensive overview of the general methods used in industry for the extraction of heparin from animal tissue.

  5. In vivo studies on the binding of heparin and its fractions with platelet factor 4

    International Nuclear Information System (INIS)

    Walz, D.A.; Hung, G.L.

    1985-01-01

    PF4 has a half-life in plasma of less than 3 minutes, and its rapid clearance appears to be a function of binding to the vascular endothelium. Once bound to the endothelium, PF4 can be released by heparin in a time-dependent manner; recovery is greater the sooner heparin is administered following PF4 infusion. This heparin-induced release of PF4 can be abolished if the heparin is first complexed with hexadimethrine bromide. Likewise, this heparin-induced release of PF4 is dependent upon the type of heparin used; low molecular weight heparin fractions and fragments do not cause the PF4 rebound seen with intact heparin. Thus, it would appear that low molecular weight forms of heparin are advantageous in that their in vivo administration would not be mediated by such platelet modulators as PF4

  6. Heparin modulates human intestinal smooth muscle (HISM) cell proliferation and matrix production

    International Nuclear Information System (INIS)

    Graham, M.; Perr, H.; Drucker, D.E.; Diegelmann, R.F.

    1986-01-01

    (HISM) cell proliferation and collagen production may play a role in the pathogenesis of intestinal stricture in Crohn's disease. The present studies were performed to evaluate the effects of heparin, a known modulator of vascular smooth muscle cells, on HISM cell proliferation and collagen production. Heparin (100 μg/ml) was added daily to HISM cell cultures for cell proliferation studies and for 24 hours at various time points during culture for collagen synthesis studies. Collagen synthesis was determined by the uptake of 3 H proline into collagenase-sensitive protein. Heparin completely inhibited cell proliferation for 7 days, after which cell numbers increased but at a slower rate than controls. Cells released from heparin inhibition demonstrated catch-up growth to control levels. Collagen production was significantly inhibited by 24 hours exposure to heparin but only at those times during culture when collagen synthesis was maximal (8 to 12 days). Non-collagen protein synthesis was inhibited by heparin at all time points during culture. Heparin through its modulation of HISM cells may play an important role in the control of the extracellular matrix of the intestinal wall

  7. Activation of M1 macrophages in sepsis-induced acute kidney injury in response to heparin-binding protein.

    Directory of Open Access Journals (Sweden)

    Li Xing

    Full Text Available In the early stage of sepsis, M1 macrophages result in the production of inflammatory mediators and AKI. Heparin-binding protein (HBP have been shown to play important roles in sepsis-induced AKI. In this study, we investigate the association of HBP with M1 macrophages in sepsis-induced AKI.Male C57BL6 mice were subjected to cecal ligation and puncture (CLP or sham surgery. Biochemical and histological renal damage was assessed. Macrophage infiltration was assessed by immunohistochemistry. RT-PCR was used to investigate the expression of heparin-binding protein (HBP, the inducible nitric oxide synthase (iNOS and arginase 1 (Arg-1 mRNAs. Western blots were performed to assay the tissue levels of HBP, tumor necrosis factor alpha (TNF-α and interleukin-6 (IL-6.High levels of HBP were obviously detected 24 h after sepsis-induced AKI. Heparin inhibited HBP expression during sepsis-induced AKI. The suppression of HBP expression by heparin injection after the establishment of sepsis-induced AKI resulted in a reduction in renal injury severity accompanied with a significant repression of M1 macrophage activation and expression of TNF-α and IL-6.HBP plays an important role in the initial inflammatory reaction associated with sepsis-induced AKI, presumably by activating M1 macrophages and suppressing TNF-α and IL-6 secretion.

  8. Metabolic engineering of Chinese hamster ovary cells: towards a bioengineered heparin.

    Science.gov (United States)

    Baik, Jong Youn; Gasimli, Leyla; Yang, Bo; Datta, Payel; Zhang, Fuming; Glass, Charles A; Esko, Jeffrey D; Linhardt, Robert J; Sharfstein, Susan T

    2012-03-01

    Heparin is the most widely used pharmaceutical to control blood coagulation in modern medicine. A health crisis that took place in 2008 led to a demand for production of heparin from non-animal sources. Chinese hamster ovary (CHO) cells, commonly used mammalian host cells for production of foreign pharmaceutical proteins in the biopharmaceutical industry, are capable of producing heparan sulfate (HS), a related polysaccharide naturally. Since heparin and HS share the same biosynthetic pathway, we hypothesized that heparin could be produced in CHO cells by metabolic engineering. Based on the expression of endogenous enzymes in the HS/heparin pathways of CHO-S cells, human N-deacetylase/N-sulfotransferase (NDST2) and mouse heparan sulfate 3-O-sulfotransferase 1 (Hs3st1) genes were transfected sequentially into CHO host cells growing in suspension culture. Transfectants were screened using quantitative RT-PCR and Western blotting. Out of 120 clones expressing NDST2 and Hs3st1, 2 clones, Dual-3 and Dual-29, were selected for further analysis. An antithrombin III (ATIII) binding assay using flow cytometry, designed to recognize a key sugar structure characteristic of heparin, indicated that Hs3st1 transfection was capable of increasing ATIII binding. An anti-factor Xa assay, which affords a measure of anticoagulant activity, showed a significant increase in activity in the dual-expressing cell lines. Disaccharide analysis of the engineered HS showed a substantial increase in N-sulfo groups, but did not show a pattern consistent with pharmacological heparin, suggesting that further balancing the expression of transgenes with the expression levels of endogenous enzymes involved in HS/heparin biosynthesis might be necessary. Copyright © 2012 Elsevier Inc. All rights reserved.

  9. Heparin-Based Nanoparticles: An Overview of Their Applications

    Directory of Open Access Journals (Sweden)

    Maria del Pilar Rodriguez-Torres

    2018-01-01

    Full Text Available This review deals with nanoparticles synthesized using heparin. Such nanoparticles have been widely studied since a long time ago, obtaining satisfactory outcomes. An outstanding aspect of these nanoparticles is that they possess good biocompatible characteristics, and since heparin is produced in the human body within the mast cells, this makes these nanoparticles useful for future applications like imaging, disease and cancer treatment, and antibacterial activity. They can also be used for applications that are not oriented directly to the medical and biological areas such as in the case of analyte detection in aqueous solution, although such studies are very few. These nanoparticles synthesis is mainly through wet chemistry methods, using heparin that could have been modified or not.

  10. Anticoagulant effect of low molecular weight heparin on central ...

    African Journals Online (AJOL)

    Purpose: To analyse the effect of low molecular weight heparin on venous catheters in haemodialysis patients. Methods: This study included 140 eligible patients who were randomly and evenly divided into two groups, viz, a study group that received low molecular weight heparin and a control group that received ...

  11. Nerve growth factor loaded heparin/chitosan scaffolds for accelerating peripheral nerve regeneration.

    Science.gov (United States)

    Li, Guicai; Xiao, Qinzhi; Zhang, Luzhong; Zhao, Yahong; Yang, Yumin

    2017-09-01

    Artificial chitosan scaffolds have been widely investigated for peripheral nerve regeneration. However, the effect was not as good as that of autologous grafts and therefore could not meet the clinical requirement. In the present study, the nerve growth factor (NGF) loaded heparin/chitosan scaffolds were fabricated via electrostatic interaction for further improving nerve regeneration. The physicochemical properties including morphology, wettability and composition were measured. The heparin immobilization, NGF loading and release were quantitatively and qualitatively characterized, respectively. The effect of NGF loaded heparin/chitosan scaffolds on nerve regeneration was evaluated by Schwann cells culture for different periods. The results showed that the heparin immobilization and NGF loading did not cause the change of bulk properties of chitosan scaffolds except for morphology and wettability. The pre-immobilization of heparin in chitosan scaffolds could enhance the stability of subsequently loaded NGF. The NGF loaded heparin/chitosan scaffolds could obviously improve the attachment and proliferation of Schwann cells in vitro. More importantly, the NGF loaded heparin/chitosan scaffolds could effectively promote the morphology development of Schwann cells. The study may provide a useful experimental basis to design and develop artificial implants for peripheral nerve regeneration and other tissue regeneration. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. [Thrombocytopenia induced by type II heparin and myocardial infarct: 2 case reports].

    Science.gov (United States)

    Antonijević, Nabojsa; Stanojević, Milica; Perunicić, Jovan; Djokić, Milan; Miković, Danijla; Kovac, Mirjana; Miljić, Predrag; Milosević, Rajko; Terzić, Branka; Vasiljević, Zorana

    2004-01-01

    Heparin-induced thrombocytopenia (HIT) type II is an acquired thrombophylic state and life-threatening immune complication of a heparin treatment mainly clinically manifested by marked thrombocytopenia, frequently by arterial and venous thrombosis, and sometimes by skin changes. Functional assay as heparin aggregation test and 14C-serotonin release assays are used in diagnostics as well as antigen assays of which detection tests for heparin-platelet factor 4 antibodies are most frequently used. Considering the fact that there is no single reliable assays for HIT II detection available, sometimes it is necessary to combine both of the above-mentioned types of assays. We present the case of a 57-year-old patient with an acute anterior myocardial infarction with cardiac insufficiency of III and IV degree according to Killip, recurrent ventricular fibrillation and diabetes mellitus type II developing thrombocytopenia to 37 x 10(9)/l accompanied with typical skin changes. The diagnosis was confirmed by the heparin aggregation test. The second patient aged 70 undergoing the treatment for anteroseptal myocardial infarction and reinfarction of the inferior wall complicated by a cardiogenic shock and acute right bundle branch block developed thrombocytopenia 59 x 10(9)/l on the third day of the heparin therapy, with the remark that he had received a heparin therapy during the first infarction as well. Antibodies against heparin-platelet factor 4 were detected by particle gel ID-HPF4 immuno-assay. In both patients, the disease had a lethal outcome despite all then available therapeutic measures applied. Further on we discuss advantages of certain types of tests, a therapy doctrine, need for urgent therapeutic measures, inclusive of the administration of antithrombins, avoidance of harmful procedures like low-molecular-weight heparins administration and prophylactic platelet transfusion as well as preventive measures.

  13. Distribution of heparin-/sup 67/Ga in tumor-bearing rats

    Energy Technology Data Exchange (ETDEWEB)

    Hiraki, T; Ando, A; Sanada, S [Kanazawa Univ. (Japan). School of Paramedicine; Ando, I; Hisada, K

    1976-06-01

    Heparin is a kind of acidic mucopolysaccharide. The distribution of heparin-/sup 67/Ga complex in tumor-bearing rats was investigated by administering it to rats into which Yoshida sarcoma had been transplanted subcutaneously. These rats were sacrificed at 10 minutes, 30 minutes, 1 hour and 3 hours after injection. Radioactivity of the tumor, blood, muscle, liver, kidney, spleen and urine were measured with a well-type scintillation counter. Retention values in these organs and excretion rates in the urine were calculated. Excretion rates (%/dose) of heparin-/sup 67/Ga in 10 min., 30 min., 1 hour, and 3 hours were 38.2%, 67.5%, 79.5% and 78.0%, respectively. From these facts, it was thought that heparin-/sup 67/Ga complex was not suitable for tumor scanning, but that this compound might be a suitable agent for the renal function test.

  14. Endostatin competes with bFGF for binding to heparin-like glycosaminoglycans

    International Nuclear Information System (INIS)

    Reis, Renata C.M.; Schuppan, Detlef; Barreto, Aline C.; Bauer, Michael; Bork, Jens P.; Hassler, Gerda; Coelho-Sampaio, Tatiana

    2005-01-01

    Endostatin is a potent inhibitor of angiogenesis and tumor growth. Here, we used human endothelial cells from lung capillaries to investigate if endostatin competes with the proangiogenic growth factors, bFGF and VEGF, for binding to costimulatory heparan sulfate molecules. Endostatin inhibited 79% and 95% of the increase in proliferation induced by bFGF and VEGF 165 , respectively. The stimulatory effect of VEGF 165 was not affected by the presence of exogenous heparin, while that of bFGF was further enhanced in the presence of up to 0.1 μg/ml heparin. The heparin-binding protein protamine completely blocked bFGF-stimulated proliferation, while it did not affect the response to VEGF 165 . Simultaneous addition of endostatin and protamine led to additive effects both in inhibition of proliferation and induction of apoptosis. Although bFGF was found to bind more strongly to heparin-Sepharose than endostatin, the latter, but not the former, displaced protamine from heparin in solution, which supports the notion that endostatin can compete with bFGF for binding to heparan sulfate in vivo. Taken as a whole, our results demonstrate that there is a direct connection between the dependence of endostatin activity on heparin-like glycosaminoglycans and its ability to antagonize bFGF

  15. High-performance bidiagonal reduction using tile algorithms on homogeneous multicore architectures

    KAUST Repository

    Ltaief, Hatem

    2013-04-01

    This article presents a new high-performance bidiagonal reduction (BRD) for homogeneous multicore architectures. This article is an extension of the high-performance tridiagonal reduction implemented by the same authors [Luszczek et al., IPDPS 2011] to the BRD case. The BRD is the first step toward computing the singular value decomposition of a matrix, which is one of the most important algorithms in numerical linear algebra due to its broad impact in computational science. The high performance of the BRD described in this article comes from the combination of four important features: (1) tile algorithms with tile data layout, which provide an efficient data representation in main memory; (2) a two-stage reduction approach that allows to cast most of the computation during the first stage (reduction to band form) into calls to Level 3 BLAS and reduces the memory traffic during the second stage (reduction from band to bidiagonal form) by using high-performance kernels optimized for cache reuse; (3) a data dependence translation layer that maps the general algorithm with column-major data layout into the tile data layout; and (4) a dynamic runtime system that efficiently schedules the newly implemented kernels across the processing units and ensures that the data dependencies are not violated. A detailed analysis is provided to understand the critical impact of the tile size on the total execution time, which also corresponds to the matrix bandwidth size after the reduction of the first stage. The performance results show a significant improvement over currently established alternatives. The new high-performance BRD achieves up to a 30-fold speedup on a 16-core Intel Xeon machine with a 12000×12000 matrix size against the state-of-the-art open source and commercial numerical software packages, namely LAPACK, compiled with optimized and multithreaded BLAS from MKL as well as Intel MKL version 10.2. © 2013 ACM.

  16. Output Current Ripple Reduction Algorithms for Home Energy Storage Systems

    Directory of Open Access Journals (Sweden)

    Jin-Hyuk Park

    2013-10-01

    Full Text Available This paper proposes an output current ripple reduction algorithm using a proportional-integral (PI controller for an energy storage system (ESS. In single-phase systems, the DC/AC inverter has a second-order harmonic at twice the grid frequency of a DC-link voltage caused by pulsation of the DC-link voltage. The output current of a DC/DC converter has a ripple component because of the ripple of the DC-link voltage. The second-order harmonic adversely affects the battery lifetime. The proposed algorithm has an advantage of reducing the second-order harmonic of the output current in the variable frequency system. The proposed algorithm is verified from the PSIM simulation and experiment with the 3 kW ESS model.

  17. Quantitation of heparosan with heparin lyase III and spectrophotometry.

    Science.gov (United States)

    Huang, Haichan; Zhao, Yingying; Lv, Shencong; Zhong, Weihong; Zhang, Fuming; Linhardt, Robert J

    2014-02-15

    Heparosan is Escherichia coli K5 capsule polysaccharide, which is the key precursor for preparing bioengineered heparin. A rapid and effective quantitative method for detecting heparosan is important in the large-scale production of heparosan. Heparin lyase III (Hep III) effectively catalyzes the heparosan depolymerization, forming unsaturated disaccharides that are measurable using a spectrophotometer at 232 nm. We report a new method for the quantitative detection of heparosan with heparin lyase III and spectrophotometry that is safer and more specific than the traditional carbazole assay. In an optimized detection system, heparosan at a minimum concentration of 0.60 g/L in fermentation broth can be detected. Copyright © 2013 Elsevier Inc. All rights reserved.

  18. Quantitative determination of heparin levels in serum with microtiter plate-format optode

    International Nuclear Information System (INIS)

    Kim, Sung Bae; Kang, Tae Young; Cha, Geun Sig; Nam, Hakhyun

    2006-01-01

    A new assay method has been developed for the quantitative determination of heparin in serum using a microtiter plate-format optode (MPO). Heparin and proton in physiological sample are favorably co-extracted into the solvent polymeric optode membrane containing both cationic lipophilic additive, tridodecylmethyl ammonium chloride (TDMAC), and proton-selective ionophore, 3-hydroxy-4-(4-nitrophenylazo)-phenyloctadecanoate (ETH 2412), resulting in the absorbance change of the membrane to varying heparin levels. The optimized MPO composition contains low polymer-to-plasticizer ratio compared to those of conventional ion-selective optodes or electrodes, i.e., poly(vinyl chloride) (20.0)/dioctylsebacate (76.3)/ETH 2412 (1.7)/TDMAC (1.0) (wt.%): it resulted in a quantitative response to heparin from 0 to 15 unit/mL in serum with high sensitivity. The heparin-protamine titration on the MPO could provide rapid and precise determination of heparin. It was shown that the heparin levels in serum sample could be determined from the rate of absorbance change over time (ΔA/Δt); this method was more effective than the direct absorbance measurement in minimizing the interferences from color and turbidity of serum samples. MPO has been developed as a high throughput and convenient disposable sensing device, and may find a wide application in the determination of polyions and charged macromolecules

  19. Cancer Cell Adhesion and Metastasis: Selectins, Integrins, and the Inhibitory Potential of Heparins

    Directory of Open Access Journals (Sweden)

    Gerd Bendas

    2012-01-01

    Full Text Available Cell adhesion molecules play a significant role in cancer progression and metastasis. Cell-cell interactions of cancer cells with endothelium determine the metastatic spread. In addition, direct tumor cell interactions with platelets, leukocytes, and soluble components significantly contribute to cancer cell adhesion, extravasation, and the establishment of metastatic lesions. Clinical evidence indicates that heparin, commonly used for treatment of thromboembolic events in cancer patients, is beneficial for their survival. Preclinical studies confirm that heparin possesses antimetastatic activities that lead to attenuation of metastasis in various animal models. Heparin contains several biological activities that may affect several steps in metastatic cascade. Here we focus on the role of cellular adhesion receptors in the metastatic cascade and discuss evidence for heparin as an inhibitor of cell adhesion. While P- and L-selectin facilitation of cellular contacts during hematogenous metastasis is being accepted as a potential target of heparin, here we propose that heparin may also interfere with integrin activity and thereby affect cancer progression. This review summarizes recent findings about potential mechanisms of tumor cell interactions in the vasculature and antimetastatic activities of heparin.

  20. 99m Tc-labeled heparin test in orthopaedic surgery

    International Nuclear Information System (INIS)

    Bouvier, J.F.; Lafon, J.C.; Colin, M.; Chatelut, J.; Beaubatie, F.

    1983-01-01

    99m Tc-labeled heparin test was performed for early detection of phlebitis or pulmonary embolism after orthopaedic prothesis. Heparinic treatment and surgery per se were demonstrated to have no effect on the results. If this test demonstrates a statistical difference for pathologic patients, it is of greater value to consider ratio between rates before and after intervention [fr

  1. Anti-Platelet Factor 4/Heparin Antibody Formation Occurs Endogenously and at Unexpected High Frequency in Polycythemia Vera

    Directory of Open Access Journals (Sweden)

    Sara C. Meyer

    2017-01-01

    Full Text Available Background. Myeloproliferative neoplasms (MPN encounter thromboses due to multiple known risk factors. Heparin-induced thrombocytopenia (HIT is a thrombotic syndrome mediated by anti-platelet factor 4 (PF4/heparin antibodies with undetermined significance for thrombosis in MPN. We hypothesized that anti-PF4/heparin Ab might occur in MPN and promote thrombosis. Methods. Anti-PF4/heparin antibodies were analyzed in 127 MPN patients including 76 PV and 51 ET. Screening, validation testing, and isotype testing of anti-PF4/heparin Ab were correlated with disease characteristics. Results. Anti-PF4/heparin antibodies were detected in 21% of PV and 12% of ET versus 0.3–3% in heparin-exposed patients. Validation testing confirmed anti-PF4/heparin immunoglobulins in 15% of PV and 10% of ET. Isotype testing detected 9.2% IgG and 5.3% IgM in PV and exclusively IgM in ET. IgG-positive PV patients encountered thromboses in 57.1% suggesting anti-PF4/heparin IgG may contribute to higher risk for thrombosis in MPN. Overall, 45% of PV patients experienced thromboses with 11.8% positive for anti-PF4/heparin IgG versus 7.1% in PV without thrombosis. Conclusion. Anti-PF4/heparin antibodies occur endogenously and more frequently in MPN than upon heparin exposure. Thrombotic risk increases in anti-PF4/heparin IgG-positive PV reflecting potential implications and calling for larger, confirmatory cohorts. Anti-PF4/heparin IgG should be assessed upon thrombosis in PV to facilitate avoidance of heparin in anti-PF4/heparin IgG-positive PV.

  2. Biomimetic synthesis and biocompatibility evaluation of carbonated apatites template-mediated by heparin

    Energy Technology Data Exchange (ETDEWEB)

    Deng, Yi [Department of Oral and Maxillofacial Surgery, Laboratory of Interdisciplinary Studies, School and Hospital of Stomatology, Peking University, Beijing 100081 (China); Center for Biomedical Materials and Tissue Engineering, Academy for Advanced Interdisciplinary Studies, Peking University, Beijing 100871 (China); Sun, Yuhua [Department of Oral and Maxillofacial Surgery, Laboratory of Interdisciplinary Studies, School and Hospital of Stomatology, Peking University, Beijing 100081 (China); Chen, Xiaofang [Center for Biomedical Materials and Tissue Engineering, Academy for Advanced Interdisciplinary Studies, Peking University, Beijing 100871 (China); Zhu, Peizhi, E-mail: pzzhu@umich.edu [Center for Biomedical Materials and Tissue Engineering, Academy for Advanced Interdisciplinary Studies, Peking University, Beijing 100871 (China); Department of Chemistry, University of Michigan, Ann Arbor, MI 48109-1055 (United States); Wei, Shicheng, E-mail: sc-wei@pku.edu.cn [Department of Oral and Maxillofacial Surgery, Laboratory of Interdisciplinary Studies, School and Hospital of Stomatology, Peking University, Beijing 100081 (China); Center for Biomedical Materials and Tissue Engineering, Academy for Advanced Interdisciplinary Studies, Peking University, Beijing 100871 (China)

    2013-07-01

    Biomimetic synthesis of carbonated apatites with good biocompatibility is a promising strategy for the broadening application of apatites for bone tissue engineering. Most researchers were interested in collagen or gelatin-based templates for synthesis of apatite minerals. Inspired by recent findings about the important role of polysaccharides in bone biomineralization, here we reported that heparin, a mucopolysaccharide, was used to synthesize carbonated apatites in vitro. The results indicated that the Ca/P ratio, carbon content, crystallinity and morphology of the apatites varied depending on the heparin concentration and the initial pH value. The morphology of apatite changed from flake-shaped to needle-shaped, and the degree of crystallinity decreased with the increasing of heparin concentration. Biocompatibility of the apatites was tested by proliferation and alkaline phosphatase activity of MC3T3-E1 cells. The results suggested that carbonated apatites synthesized in the presence of heparin were more favorable to the proliferation and differentiation of MC3T3-E1 cells compared with traditional method. In summary, the heparin concentration and the initial pH value play a key role in the chemical constitution and morphology, as well as biological properties of apatites. These biocompatible nano-apatite crystals hold great potential to be applied as bioactive materials for bone tissue engineering. - Highlights: • Heparin was used as a template to synthesize needle-shaped nano-apatite. • Changing the pH value and concentration led to different properties of apatite. • Apatite prepared by heparin was more favorable to the osteogenic differentiation. • Possible synthesis mechanism of apatite templated by heparin was described.

  3. Characterization of currently marketed heparin products: key tests for LMWH quality assurance.

    Science.gov (United States)

    Ye, Hongping; Toby, Timothy K; Sommers, Cynthia D; Ghasriani, Houman; Trehy, Michael L; Ye, Wei; Kolinski, Richard E; Buhse, Lucinda F; Al-Hakim, Ali; Keire, David A

    2013-11-01

    During the 2007-2008 heparin crisis it was found that the United States Pharmacopeia (USP) testing monograph for heparin sodium or low molecular weight heparins did not detect the presence of the contaminant, oversulfated chondroitin sulfate (OSCS). In response to this concern, new tests and specifications were developed by the Food and Drug Administration (FDA) and USP and put in place to detect not only the contaminant OSCS, but also to improve assurance of quality and purity of these drug products. The USP monographs for the low molecular weight heparins (LMWHs) approved for use in the United States (dalteparin, tinzaparin and enoxaparin) are also undergoing revision to include many of the same tests used for heparin sodium, including; one-dimensional (1D) 500 MHz (1)H NMR, SAX-HPLC, percent galactosamine in total hexosamine and anticoagulation time assays with purified Factor IIa or Factor Xa. These tests represent orthogonal approaches for heparin identification, measurement of bioactivity and for detection of process impurities or contaminants in these drug products. Here we describe results from a survey of multiple lots from three types of LMWHs in the US market which were collected after the 2009 heparin sodium monograph revision. In addition, innovator and generic versions of formulated enoxaparin products purchased in 2011 are compared using these tests and found to be highly similar within the discriminating power of the assays applied. Published by Elsevier B.V.

  4. Effects of directional microphone and adaptive multichannel noise reduction algorithm on cochlear implant performance.

    Science.gov (United States)

    Chung, King; Zeng, Fan-Gang; Acker, Kyle N

    2006-10-01

    Although cochlear implant (CI) users have enjoyed good speech recognition in quiet, they still have difficulties understanding speech in noise. We conducted three experiments to determine whether a directional microphone and an adaptive multichannel noise reduction algorithm could enhance CI performance in noise and whether Speech Transmission Index (STI) can be used to predict CI performance in various acoustic and signal processing conditions. In Experiment I, CI users listened to speech in noise processed by 4 hearing aid settings: omni-directional microphone, omni-directional microphone plus noise reduction, directional microphone, and directional microphone plus noise reduction. The directional microphone significantly improved speech recognition in noise. Both directional microphone and noise reduction algorithm improved overall preference. In Experiment II, normal hearing individuals listened to the recorded speech produced by 4- or 8-channel CI simulations. The 8-channel simulation yielded similar speech recognition results as in Experiment I, whereas the 4-channel simulation produced no significant difference among the 4 settings. In Experiment III, we examined the relationship between STIs and speech recognition. The results suggested that STI could predict actual and simulated CI speech intelligibility with acoustic degradation and the directional microphone, but not the noise reduction algorithm. Implications for intelligibility enhancement are discussed.

  5. The US regulatory and pharmacopeia response to the global heparin contamination crisis.

    Science.gov (United States)

    Szajek, Anita Y; Chess, Edward; Johansen, Kristian; Gratzl, Gyöngyi; Gray, Elaine; Keire, David; Linhardt, Robert J; Liu, Jian; Morris, Tina; Mulloy, Barbara; Nasr, Moheb; Shriver, Zachary; Torralba, Pearle; Viskov, Christian; Williams, Roger; Woodcock, Janet; Workman, Wesley; Al-Hakim, Ali

    2016-06-09

    The contamination of the widely used lifesaving anticoagulant drug heparin in 2007 has drawn renewed attention to the challenges that are associated with the characterization, quality control and standardization of complex biological medicines from natural sources. Heparin is a linear, highly sulfated polysaccharide consisting of alternating glucosamine and uronic acid monosaccharide residues. Heparin has been used successfully as an injectable antithrombotic medicine since the 1930s, and its isolation from animal sources (primarily porcine intestine) as well as its manufacturing processes have not changed substantially since its introduction. The 2007 heparin contamination crisis resulted in several deaths in the United States and hundreds of adverse reactions worldwide, revealing the vulnerability of a complex global supply chain to sophisticated adulteration. This Perspective discusses how the US Food and Drug Administration (FDA), the United States Pharmacopeial Convention (USP) and international stakeholders collaborated to redefine quality expectations for heparin, thus making an important natural product better controlled and less susceptible to economically motivated adulteration.

  6. Interactions of oversulfated chondroitin sulfate (OSCS) from different sources with unfractionated heparin.

    Science.gov (United States)

    Gray, Angel; Litinas, Evangelos; Jeske, Walter; Fareed, Jawed; Hoppensteadt, Debra

    2012-01-01

    In 2008, oversulfated chondroitin sulfate (OSCS) was identified as the main contaminant in recalled heparin. Oversulfated chondroitin sulfate can be prepared from bovine (B), porcine (P), shark (Sh), or skate (S) origin and may produce changes in the antithrombotic, bleeding, and hemodynamic profile of heparins. This study examines the interactions of various OSCSs on heparin in animal models of thrombosis and bleeding, as well as on the anticoagulant and antiprotease effects in in vitro assays. Mixtures of 70% unfractionated heparin (UFH) with 30% OSCS from different sources were tested. In the in vitro activated partial thromboplastin time (aPTT) assay, all contaminant mixtures showed a decrease in clotting times. In addition, a significant increase in bleeding time compared to the control (UFH/saline) was observed. In the thrombosis model, no significant differences were observed. The OSCSs significantly increased anti-Xa activity in ex vivo blood samples. These results indicate that various sources of OSCS affect the hemostatic properties of heparin.

  7. A genome-wide association study of heparin-induced thrombocytopenia using an electronic medical record

    DEFF Research Database (Denmark)

    Karnes, Jason H; Cronin, Robert M; Rollin, Jerome

    2015-01-01

    Heparin-induced thrombocytopenia (HIT) is an unpredictable, potentially catastrophic adverse effect of heparin treatment resulting from an immune response to platelet factor 4 (PF4)/heparin complexes. No genome-wide evaluations have been performed to identify potential genetic influences on HIT. ...

  8. Veno-venous bypass without systemic heparinization using a centrifugal pump: a blind comparison of a heparin bonded circuit versus a non heparin bonded circuit

    NARCIS (Netherlands)

    van der Hulst, V. P.; Henny, C. P.; Moulijn, A. C.; Engbers, G.; ten Cate, H.; Gründeman, P. F.; Klopper, P. J.

    1989-01-01

    Veno-venous bypass without the use of systemic heparinization has recently become of increasing interest for application during liver transplantation and surgery on the large abdominal veins. However, possible adverse effects on blood components as demonstrated by means of hematologic and hemostatic

  9. Heparin concentration is critical for cell culture with human platelet lysate.

    Science.gov (United States)

    Hemeda, Hatim; Kalz, Jana; Walenda, Gudrun; Lohmann, Michael; Wagner, Wolfgang

    2013-09-01

    Culture media for mesenchymal stromal cells (MSCs) are generally supplemented with fetal bovine serum. Human platelet lysate (hPL) has been proven to be a very effective alternative without the risk of xenogeneic infections or immune reactions. In contrast to fetal bovine serum, hPL comprises plasma, and anticoagulants-usually unfractionated heparin (UFH)-need to be added to prevent gel formation. Cultures of MSCs in hPL media with various concentrations of UFH and enoxaparin, a low-molecular-weight heparin (LMWH), were systematically compared with regard to proliferation, fibroblastoid colony-forming unit frequency, immunophenotype and in vitro differentiation. At least 0.61 IU/mL UFH or 0.024 mg/mL LMWH was necessary for reliable prevention of coagulation of hPL pools used in this study. Higher concentrations impaired cellular proliferation in a dose-dependent manner even without benzyl alcohol, which is commonly added to heparins as a bacteriostatic agent. Colony-forming unit frequency was also reduced at higher heparin concentrations, particularly with LMWH, whereas no significant effect was observed on cellular morphology or immunophenotype. High concentrations of heparins reduced the in vitro differentiation toward adipogenic and osteogenic lineages. Heparin concentration is critical for culture of MSCs in hPL media; this is of particular relevance for cellular therapy where cell culture procedures need to be optimized and standardized. Copyright © 2013 International Society for Cellular Therapy. Published by Elsevier Inc. All rights reserved.

  10. Low-molecular weight heparin increases circulating sFlt-1 levels and enhances urinary elimination.

    Directory of Open Access Journals (Sweden)

    Henning Hagmann

    Full Text Available RATIONALE: Preeclampsia is a devastating medical complication of pregnancy which leads to maternal and fetal morbidity and mortality. While the etiology of preeclampsia is unclear, human and animal studies suggest that excessive circulating levels of soluble fms-like tyrosine-kinase-1 (sFlt-1, an alternatively spliced variant of VEGF-receptor1, contribute to the signs and symptoms of preeclampsia. Since sFlt-1 binds to heparin and heparan sulfate proteoglycans, we hypothesized that the anticoagulant heparin, which is often used in pregnancy, may interfere with the levels, distribution and elimination of sFlt-1 in vivo. OBJECTIVE: We systematically determined serum and urine levels of angiogenic factors in preeclamptic women before and after administration of low molecular weight heparin and further characterized the interaction with heparin in biochemical studies. METHODS AND RESULTS: Serum and urine samples were used to measure sFlt-1 levels before and after heparin administration. Serum levels of sFlt-1 increased by 25% after heparin administration in pregnant women. The magnitude of the increase in circulating sFlt-1 correlated with initial sFlt-1 serum levels. Urinary sFlt-1 levels were also elevated following heparin administration and levels of elimination were dependent on the underlying integrity of the glomerular filtration barrier. Biochemical binding studies employing cation exchange chromatography revealed that heparin bound sFlt-1 had decreased affinity to negatively charged surfaces when compared to sFlt-1 alone. CONCLUSION: Low molecular weight heparin administration increased circulating sFlt1 levels and enhanced renal elimination. We provide evidence that both effects may be due to heparin binding to sFlt1 and masking the positive charges on sFlt1 protein.

  11. The effect of different forms of heparin on point-of-care blood gas ...

    African Journals Online (AJOL)

    and heparin vacutainers on blood gas and electrolyte analysis and ... This prospective, cross-sectional study took place in the ED of a ... the effect of two concentrations of liquid heparin and the use of heparin vacutainers on the reliability of blood gas ... Germany) and (iv) a 2 mL plastic syringe (BD) washed with 5 000 IU/.

  12. Prospective multicentre cohort study of heparin-induced thrombocytopenia in acute ischaemic stroke patients

    Science.gov (United States)

    Kawano, Hiroyuki; Yamamoto, Haruko; Miyata, Shigeki; Izumi, Manabu; Hirano, Teruyuki; Toratani, Naomi; Kakutani, Isami; Sheppard, Jo-Ann I; Warkentin, Theodore E; Kada, Akiko; Sato, Shoichiro; Okamoto, Sadahisa; Nagatsuka, Kazuyuki; Naritomi, Hiroaki; Toyoda, Kazunori; Uchino, Makoto; Minematsu, Kazuo

    2011-01-01

    Acute ischaemic stroke patients sometimes receive heparin for treatment and/or prophylaxis of thromboembolic complications. This study was designed to elucidate the incidence and clinical features of heparin-induced thrombocytopenia (HIT) in acute stroke patients treated with heparin. We conducted a prospective multicentre cohort study of 267 patients who were admitted to three stroke centres within 7 d after stroke onset. We examined clinical data until discharge and collected blood samples on days 1 and 14 of hospitalization to test anti-platelet factor 4/heparin antibodies (anti-PF4/H Abs) using an enzyme-linked immunosorbent assay (ELISA); platelet-activating antibodies were identified by serotonin-release assay (SRA). Patients with a 4Ts score ≥4 points, positive-ELISA, and positive-SRA were diagnosed as definite HIT. Heparin was administered to 172 patients (64·4%: heparin group). Anti-PF4/H Abs were detected by ELISA in 22 cases (12·8%) in the heparin group. Seven patients had 4Ts ≥ 4 points. Among them, three patients (1·7% overall) were also positive by both ELISA and SRA. National Institutes of Health Stroke Scale score on admission was high (range, 16–23) and in-hospital mortality was very high (66·7%) in definite HIT patients. In this study, the incidence of definite HIT in acute ischaemic stroke patients treated with heparin was 1·7% (95% confidence interval: 0·4–5·0). The clinical severity and outcome of definite HIT were unfavourable. PMID:21671895

  13. Heparin removal by ecteola-cellulose pre-treatment enables the use of plasma samples for accurate measurement of anti-Yellow fever virus neutralizing antibodies.

    Science.gov (United States)

    Campi-Azevedo, Ana Carolina; Peruhype-Magalhães, Vanessa; Coelho-Dos-Reis, Jordana Grazziela; Costa-Pereira, Christiane; Yamamura, Anna Yoshida; Lima, Sheila Maria Barbosa de; Simões, Marisol; Campos, Fernanda Magalhães Freire; de Castro Zacche Tonini, Aline; Lemos, Elenice Moreira; Brum, Ricardo Cristiano; de Noronha, Tatiana Guimarães; Freire, Marcos Silva; Maia, Maria de Lourdes Sousa; Camacho, Luiz Antônio Bastos; Rios, Maria; Chancey, Caren; Romano, Alessandro; Domingues, Carla Magda; Teixeira-Carvalho, Andréa; Martins-Filho, Olindo Assis

    2017-09-01

    Technological innovations in vaccinology have recently contributed to bring about novel insights for the vaccine-induced immune response. While the current protocols that use peripheral blood samples may provide abundant data, a range of distinct components of whole blood samples are required and the different anticoagulant systems employed may impair some properties of the biological sample and interfere with functional assays. Although the interference of heparin in functional assays for viral neutralizing antibodies such as the functional plaque-reduction neutralization test (PRNT), considered the gold-standard method to assess and monitor the protective immunity induced by the Yellow fever virus (YFV) vaccine, has been well characterized, the development of pre-analytical treatments is still required for the establishment of optimized protocols. The present study intended to optimize and evaluate the performance of pre-analytical treatment of heparin-collected blood samples with ecteola-cellulose (ECT) to provide accurate measurement of anti-YFV neutralizing antibodies, by PRNT. The study was designed in three steps, including: I. Problem statement; II. Pre-analytical steps; III. Analytical steps. Data confirmed the interference of heparin on PRNT reactivity in a dose-responsive fashion. Distinct sets of conditions for ECT pre-treatment were tested to optimize the heparin removal. The optimized protocol was pre-validated to determine the effectiveness of heparin plasma:ECT treatment to restore the PRNT titers as compared to serum samples. The validation and comparative performance was carried out by using a large range of serum vs heparin plasma:ECT 1:2 paired samples obtained from unvaccinated and 17DD-YFV primary vaccinated subjects. Altogether, the findings support the use of heparin plasma:ECT samples for accurate measurement of anti-YFV neutralizing antibodies. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Nycthemeral variations of 99Tcsup(m)-labelled heparin pharmacokinetic parameters

    International Nuclear Information System (INIS)

    Decousus, M.; Gremillet, E.; Decousus, H.; Champailler, A.; Houzard, C.; Perpoint, B.; Jaubert, J.

    1985-01-01

    Six healthy volunteers received four i.v.boluses of 99 Tcsup(m)-heparin at 8.00, 14.00, 20.00 and 02.00 hours at seven-day intervals. Nine blood samples were taken covering a period of 2 h after administration. Simultaneously urine was collected and diuresis not noted. Plasma and urinary radioactivity were measured and standard pharmacokinetic parameters were calculated. Nycthemeral variations of these kinetic parameters were detected by means of distribution-free tests. Circadian rhythms were analysed by means of the cosinor method and the Gauss-Marquardt method. The mean raw value of the following parameters: apparent volume of distribution, plasmatic clearance and extra-renal metabolic clearance, increased significantly between 8.00 and 14.00 and decreased between 14.00 and 20.00. A circadian rhythm was found for the plasmatic clearance only. On the other hand the elimination half-lives and the renal clearance were unaffected by the time of the injections. These results obtained for low doses of 99 Tcsup(m)-heparin suggest a circadian rhythm of the bio-availability of heparin in man. This fact should be taken into account for the use of 99 Tcsup(m)-heparin in the diagnosis of deep-vein thrombosis and for the safe adjustment of the heparin dosages in the treatment of severe thromboembolism. (author)

  15. Highly sensitive ratiometric detection of heparin and its oversulfated chondroitin sulfate contaminant by fluorescent peptidyl probe.

    Science.gov (United States)

    Mehta, Pramod Kumar; Lee, Hyeri; Lee, Keun-Hyeung

    2017-05-15

    The selective and sensitive detection of heparin, an anticoagulant in clinics as well as its contaminant oversulfated chondroitin sulfate (OSCS) is of great importance. We first reported a ratiometric sensing method for heparin as well as OSCS contaminants in heparin using a fluorescent peptidyl probe (Pep1, pyrene-GSRKR) and heparin-digestive enzyme. Pep1 exhibited a highly sensitive ratiometric response to nanomolar concentration of heparin in aqueous solution over a wide pH range (2~11) and showed highly selective ratiometric response to heparin among biological competitors such as hyaluronic acid and chondroitin sulfate. Pep1 showed a linear ratiometric response to nanomolar concentrations of heparin in aqueous solutions and in human serum samples. The detection limit for heparin was calculated to be 2.46nM (R 2 =0.99) in aqueous solutions, 2.98nM (R 2 =0.98) in 1% serum samples, and 3.43nM (R 2 =0.99) in 5% serum samples. Pep1 was applied to detect the contaminated OSCS in heparin with heparinase I, II, and III, respectively. The ratiometric sensing method using Pep1 and heparinase II was highly sensitive, fast, and efficient for the detection of OSCS contaminant in heparin. Pep1 with heparinase II could detect as low as 0.0001% (w/w) of OSCS in heparin by a ratiometric response. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Heparin induced alterations in clearance and distribution of blood-borne microparticles following operative trauma.

    Science.gov (United States)

    Saba, T M; Antikatzides, T G

    1979-04-01

    The influence of systemic heparin administration on the vascular clearance and tissue distribution of blood-borne microparticles was evaluated in normal rats and rats after operation (laparotomy plus intestinal manipulation) utilizing an (131)I- colloid which is phagocytized by the reticuloendothelial system (RES). Intravenous heparin administration (100 USP/100g body weight) into normal animals three minutes prior to colloid injection (50 mg/lOOg) induced a significant increase in pulmonary localization of the microparticles as compared to nonheparinized control rats, while hepatic and splenic uptake were decreased. Surgical trauma decreased hepatic RE uptake and increased pulmonary localization of the microparticles when injected systemically at 60 minutes postsurgery. Heparin administration 60 minutes after surgery and three minutes prior to colloid injection, magnified the increased pulmonary localization response with an associated further depression of the RES. The ability of heparin to alter both RE clearance function and lung localization of microparticles was dose dependent and a function of the interval between heparin administration and systemic particulate infusion. Thus, low dose heparin administration was capable of stimulating RE activity while heparin in doses of excess of 50 USP units/lOOg body weight decreased RE function. These findings suggest that the functional state of the hepatic RE system can be greatly affected in a dose-dependent manner by systemic heparin administration which may influence distribution of blood-borne microparticles.

  17. 12500 E heparin and 12500 E of a semisynthetic heparin analogue (SSHA) in preventing thrombosis during radiotherapy of gynaecological carcinomas

    International Nuclear Information System (INIS)

    Hilscher, T.M.

    1983-01-01

    The effects of 12500 E calcium heparin given once daily were contrasted with those seen under daily treatment with 12500 E of a semisynthetic heparin analogue (SSHA) and evaluated using iodine-125-labelled fibrinogen. The study included 80 patients, who were randomly assigned to the two treatment groups on a 1:1 basis. The findings revealed here led to the conclusion that both drugs, administered once daily by the subcutaneous route, were effective in preventing the occurrence of thrombosis during radiation treatment of gynaecological tumours. (orig./MG) [de

  18. Heparin and glutathione II: correlation between decondensation of bull sperm cells and its nucleons.

    Science.gov (United States)

    Delgado, N M; Flores-Alonso, J C; Rodríguez-Hernández, H M; Merchant-Larios, H; Reyes, R

    2001-01-01

    The correlation between the kinetics of bull sperm nuclear and nucleon decondensation induced by the action of physiological concentrations of heparin/GSH was studied. Sperm and nucleon suspensions were incubated at 37 degrees C in salt medium, at a constant concentration of either heparin or GSH and increasing concentrations of the other reagent. Even though nucleons are pretreated with DTT/CTAB, when they are incubated alone with GSH for 96 h, they remain intact, no matter which concentration is employed, and it was impossible to observe the slightest sign of nuclei decondensation. Therefore, rupture of disulfide bridges is not the main mechanism to induce nuclei decondensation and perhaps the GSH role resides in potentate the heparin effect by increasing its negative charge. Nevertheless, nucleons reach 95% of chromatin decondensation in the presence of heparin plus GSH or heparin alone. The fact that the correlation between heparin and GSH concentrations needed to induce sperm nuclei decondensation was 3- to 4-fold greater that in nucleons might be due to the complete lack of nucleon membranes. Heparin/GSH seem to induce nuclei decondensation by an ionic chromatin charge neutralization mechanism.

  19. Cationization of heparin for film applications

    Czech Academy of Sciences Publication Activity Database

    Šimkovic, I.; Mendichi, R.; Kelnar, Ivan; Filip, J.; Hricovíni, M.

    2015-01-01

    Roč. 115, 22 January (2015), s. 551-558 ISSN 0144-8617 Institutional support: RVO:61389013 Keywords : heparin * cationization * NMR Subject RIV: CD - Macromolecular Chemistry Impact factor: 4.219, year: 2015

  20. Structure-Activity Relationships of Bioengineered Heparin/Heparan Sulfates Produced in Different Bioreactors

    Directory of Open Access Journals (Sweden)

    Ha Na Kim

    2017-05-01

    Full Text Available Heparin and heparan sulfate are structurally-related carbohydrates with therapeutic applications in anticoagulation, drug delivery, and regenerative medicine. This study explored the effect of different bioreactor conditions on the production of heparin/heparan sulfate chains via the recombinant expression of serglycin in mammalian cells. Tissue culture flasks and continuously-stirred tank reactors promoted the production of serglycin decorated with heparin/heparan sulfate, as well as chondroitin sulfate, while the serglycin secreted by cells in the tissue culture flasks produced more highly-sulfated heparin/heparan sulfate chains. The serglycin produced in tissue culture flasks was effective in binding and signaling fibroblast growth factor 2, indicating the utility of this molecule in drug delivery and regenerative medicine applications in addition to its well-known anticoagulant activity.

  1. SPECIFIC ASPECTS OF INTERACTION OF PLATELETS WITH THE HEPARINIZED MATERIALS

    Directory of Open Access Journals (Sweden)

    E.A. Nemets

    2012-01-01

    Full Text Available Comparative analysis of anticoagulant nature on medical materials testing was done. It was found that change of citrate by heparin is accompanied by significant changes in platelet adhesion and activation. This results allowed us to arrive at a conclusion about reasonability of heparin usage as anticoagulant in in vitro testing. 

  2. Safety of low-molecular-weight heparin in pregnancy: a systematic review

    NARCIS (Netherlands)

    Sanson, B. J.; Lensing, A. W.; Prins, M. H.; Ginsberg, J. S.; Barkagan, Z. S.; Lavenne-Pardonge, E.; Brenner, B.; Dulitzky, M.; Nielsen, J. D.; Boda, Z.; Turi, S.; Mac Gillavry, M. R.; Hamulyák, K.; Theunissen, I. M.; Hunt, B. J.; Büller, H. R.

    1999-01-01

    Unfractionated heparin (UFH) remains the anticoagulant of choice during pregnancy. Low-molecular-weight heparins (LMWH) are an attractive alternative to UFH due to their logistic advantages and their association with a lower incidence of osteoporosis and HIT. We reviewed all published clinical

  3. Qualitative and Quantitative Analysis of Heparin during Precipitation by Near-Infrared Spectroscopy

    OpenAIRE

    Lian Li; Jinfeng Wang; Hengchang Zang; Hui Zhang; Wei Jiang; Shang Chen; Fengshan Wang

    2016-01-01

    Heparin is a glycosaminoglycan (GAG) that plays an important role in the blood coagulation system. Its quality is of great importance, so it is necessary to develop a fast analytical method during the manufacture process to analyse the quality of heparin produced. In this study, the heparin contents of 80 samples collected from five batches during the precipitation process were analysed using nearinfrared (NIR) spectroscopy and a chemometrics approach. This was done in order to improve the ef...

  4. Dansyl (5-dimethylaminonaphthalene-1-sulphonyl)-heparin binds antithrombin III and platelet factor 4 at separate sites

    Science.gov (United States)

    Piepkorn, Michael W.

    1981-01-01

    Antithrombin III binds to, and thereby augments the fluorescence of, dansyl-(5-dimethylaminonaphthalene-1-sulphonyl)-heparin; platelet factor 4 binding to the fluorescent heparin has little of this effect. Competition studies in which antithrombin III competes with platelet factor 4 for heparin binding demonstrate that heparin can simultaneously bind both proteins. PMID:7317004

  5. An MPCA/LDA Based Dimensionality Reduction Algorithm for Face Recognition

    Directory of Open Access Journals (Sweden)

    Jun Huang

    2014-01-01

    Full Text Available We proposed a face recognition algorithm based on both the multilinear principal component analysis (MPCA and linear discriminant analysis (LDA. Compared with current traditional existing face recognition methods, our approach treats face images as multidimensional tensor in order to find the optimal tensor subspace for accomplishing dimension reduction. The LDA is used to project samples to a new discriminant feature space, while the K nearest neighbor (KNN is adopted for sample set classification. The results of our study and the developed algorithm are validated with face databases ORL, FERET, and YALE and compared with PCA, MPCA, and PCA + LDA methods, which demonstrates an improvement in face recognition accuracy.

  6. The role of heparin in sepsis: much more than just an anticoagulant.

    Science.gov (United States)

    Li, Xu; Ma, Xiaochun

    2017-11-01

    Despite progress in antibiotic treatment, mechanical ventilation, fluid resuscitation and blood glucose maintenance, sepsis remains a cause of high mortality in the intensive care unit to date, there are no proven treatment strategies for the routine management of septic patients. The extensive interaction between inflammation and coagulation contributes to the basic pathophysiology of sepsis. Thus, the agents that attenuate the activation of both inflammation and coagulation may improve the outcome in sepsis. Apart from the well-known anticoagulant effects of heparin, it also possesses various immunomodulatory properties and protects glycocalyx from shedding. Hence, heparin seems to be such an agent. Immunothrombosis plays an important role in early host defence against bacterial dissemination, thus the proper timing for anticoagulant therapy should be determined. We review the available experimental and clinical data supporting the use of heparin in sepsis. At this time the use of heparin in the treatment of sepsis is conflicting. Future trials of heparin therapy for sepsis should concentrate on the very severely ill patients, in whom benefit is most likely to be demonstrated. © 2017 John Wiley & Sons Ltd.

  7. Feature Reduction Based on Genetic Algorithm and Hybrid Model for Opinion Mining

    Directory of Open Access Journals (Sweden)

    P. Kalaivani

    2015-01-01

    Full Text Available With the rapid growth of websites and web form the number of product reviews is available on the sites. An opinion mining system is needed to help the people to evaluate emotions, opinions, attitude, and behavior of others, which is used to make decisions based on the user preference. In this paper, we proposed an optimized feature reduction that incorporates an ensemble method of machine learning approaches that uses information gain and genetic algorithm as feature reduction techniques. We conducted comparative study experiments on multidomain review dataset and movie review dataset in opinion mining. The effectiveness of single classifiers Naïve Bayes, logistic regression, support vector machine, and ensemble technique for opinion mining are compared on five datasets. The proposed hybrid method is evaluated and experimental results using information gain and genetic algorithm with ensemble technique perform better in terms of various measures for multidomain review and movie reviews. Classification algorithms are evaluated using McNemar’s test to compare the level of significance of the classifiers.

  8. Update on the clinical use of the low-molecular-weight heparin, parnaparin

    Directory of Open Access Journals (Sweden)

    Giuseppe Camporese

    2009-09-01

    Full Text Available Giuseppe Camporese1, Enrico Bernardi2, Franco Noventa31Unit of Angiology and 3Department of Clinical and Experimental Medicine, Clinical Epidemiology Group, University Hospital of Padua, Italy; 2Department of Emergency and Accident Medicine, Hospital of Conegliano Veneto, ItalyAbstract: Parnaparin is a low-molecular-weight heparin that has widely shown its efficacy and safety in prevention of venous thromboembolism, in the treatment of chronic venous disorders, and in the treatment of venous and arterial (stable and unstable angina, acute ST-segment elevation myocardial infarction thrombosis. Parnaparin at the respective dosages of 3200, 4250, 6400, or 12800 IUaXa for a period ranging from 3 to 5 days to 6 months, is usually administered subcutaneously by means of once-daily regimen and is better tolerated than unfractionated heparin at the injection site. In the variety of commercially available low-molecular-weight heparins, parnaparin represents a useful therapeutic option, even though little evidence is available comparing the superiority or the equivalent efficacy and safety of parnaparin to that of the unfractionated heparin or placebo. This review summarizes the available literature on the use of parnaparin in different settings of cardiovascular diseases, including papers published during the past year and ongoing studies.Keywords: low-molecular-weight heparin, heparin, parnaparin, acute coronary syndromes, venous thromboembolism

  9. Purification of foot-and-mouth disease virus by heparin as ligand for certain strains.

    Science.gov (United States)

    Du, Ping; Sun, Shiqi; Dong, Jinjie; Zhi, Xiaoying; Chang, Yanyan; Teng, Zhidong; Guo, Huichen; Liu, Zaixin

    2017-04-01

    The goal of this project was to develop an easily operable and scalable process for the recovery and purification of foot-and-mouth disease virus (FMDV) from cell culture. Heparin resins HipTrap Heparin HP and AF-Heparin HC-650 were utilized to purify FMDV O/HN/CHA/93. Results showed that the purity of AF-Heparin HC-650 was ideal. Then, the O/HN/CHA/93, O/Tibet/CHA/99, Asia I/HN/06, and A/CHA/HB/2009 strains were purified by AF-Heparin HC-650. Their affinity/virus recoveries were approximately 51.2%/45.8%, 71.5%/70.9%, 96.4%/73.5, and 59.5%/42.1%, respectively. During a stepwise elution strategy, the viral particles were mainly eluted at 300mM ionic strength peaks. The heparin affinity chromatography process removed more than 94% of cellular and medium proteins. Anion exchange resin Capto Q captured four FMD virus particles; 40% of binding proteins and 80%-90% of viral particles were eluted at 450mM NaCl. Moreover, ionic strength varied from 30 to 450mM had no effect on the immunity to FMDV. The results revealed that heparin sulfate may be the main receptor for CHA/99 strain attachment-susceptible cells. Heparin affinity chromatography can reach perfect results, especially when used as a ligand of the virus. Anion exchange is useful only as previous step for further purification. Copyright © 2016. Published by Elsevier B.V.

  10. Covalently bound conjugates of albumin and heparin: Synthesis, fractionation and characterization

    NARCIS (Netherlands)

    Hennink, Wim E.; Feijen, Jan; Ebert, Charles D.; Kim, Sung Wan

    1983-01-01

    Covalently bound conjugates of human serum albumin and heparin were prepared as compounds which could improve the blood-compatibility of polymer surfaces either by preadsorption or by covalent coupling of the conjugates onto blood contacting surfaces. The conjugates (10–16 weight % of heparin) were

  11. Effect of a solution containing citrate/Methylene Blue/parabens on Staphylococcus aureus bacteria and biofilm, and comparison with various heparin solutions.

    Science.gov (United States)

    Sauer, Karin; Steczko, Janusz; Ash, Stephen R

    2009-05-01

    Some antibiotic solutions increase bacterial resistance and may cause toxic side effects. Heparin, frequently used as an anticoagulant in catheter lock solutions, may cause bleeding and stimulate biofilm formation. The aim of this study was to investigate the effect of a new antibacterial/antithrombotic solution, citrate/Methylene Blue/parabens (C/MB/P), versus various heparin solutions on the viability and the structure of preformed mature biofilms of Staphylococcus aureus bacteria. The degree of eradication of both planktonic and sessile microorganisms was evaluated. The changes in the structure of biofilms after exposure to C/MB/P and several concentrations of heparin were analysed by means of confocal laser scanning microscopy. COMSTAT image analysis was utilized to compare biofilm biomass, average and maximum height, surface coverage and roughness coefficient. Viability studies were performed on both biofilms and supernatant solutions. C/MB/P, in contrast to heparin solutions, significantly reduced biofilm biomass and thickness and reduced viability by 5 log when compared with saline treatment. No viable planktonic bacteria were detected and the few remaining biofilm cells appeared to be lysed. In contrast, most heparin solutions only reduced viability up to 1.0 log and failed to eradicate planktonic bacteria. C/MB/P has a rapid bactericidal effect on the preformed, mature biofilm of S. aureus. The structural changes of biofilms treated with C/MB/P, together with the observed log reduction of viable biofilm cells, confirmed the high potential of this solution to eliminate sessile bacteria. Furthermore, the tested solution entirely eliminated planktonic bacteria detached from the biofilm.

  12. Characterization of currently marketed heparin products: key tests for quality assurance.

    Science.gov (United States)

    Keire, David A; Ye, Hongping; Trehy, Michael L; Ye, Wei; Kolinski, Richard E; Westenberger, Benjamin J; Buhse, Lucinda F; Nasr, Moheb; Al-Hakim, Ali

    2011-01-01

    During the 2007-2008 heparin crisis, it was found that the United States Pharmacopeia (USP) testing monograph for unfractionated heparin sodium (UFH) did not detect the presence of the contaminant, oversulfated chondroitin sulfate (OSCS) in heparin. In response to this concern, new tests and specifications were developed by the Food and Drug Administration (FDA) and USP and put in place to not only detect the contaminant OSCS but also to improve assurance of quality and purity of the drug product. Additional tests were also developed to monitor the heparin supply chain for other possible economically motivated additives or impurities. In 2009, a new USP monograph was put in place that includes 500 MHz (1)H NMR, SAX-HPLC, %galactosamine in total hexosamine, and anticoagulation time assays with purified factor IIa or factor Xa. These tests represent orthogonal approaches for UFH identification, measurement of bioactivity, and for detection of process impurities or contaminants in UFH. The FDA has applied these analytical approaches to the study of UFH active pharmaceutical ingredients in the marketplace. Here, we describe results from a comprehensive survey of UFH collected from seven different sources after the 2009 monograph revision and compare these data with results obtained on other heparin samples collected during the 2007-2008 crisis.

  13. A Heparin Binding Motif Rich in Arginine and Lysine is the Functional Domain of YKL-40

    Directory of Open Access Journals (Sweden)

    Nipaporn Ngernyuang

    2018-02-01

    Full Text Available The heparin-binding glycoprotein YKL-40 (CHI3L1 is intimately associated with microvascularization in multiple human diseases including cancer and inflammation. However, the heparin-binding domain(s pertinent to the angiogenic activity have yet been identified. YKL-40 harbors a consensus heparin-binding motif that consists of positively charged arginine (R and lysine (K (RRDK; residues 144–147; but they don't bind to heparin. Intriguingly, we identified a separate KR-rich domain (residues 334–345 that does display strong heparin binding affinity. A short synthetic peptide spanning this KR-rich domain successfully competed with YKL-40 and blocked its ability to bind heparin. Three individual point mutations, where alanine (A substituted for K or R (K337A, K342A, R344A, led to remarkable decreases in heparin-binding ability and angiogenic activity. In addition, a neutralizing anti-YKL-40 antibody that targets these residues and prevents heparin binding impeded angiogenesis in vitro. MDA-MB-231 breast cancer cells engineered to express ectopic K337A, K342A or R344A mutants displayed reduced tumor development and compromised tumor vessel formation in mice relative to control cells expressing wild-type YKL-40. These data reveal that the KR-rich heparin-binding motif is the functional heparin-binding domain of YKL-40. Our findings shed light on novel molecular mechanisms underlying endothelial cell angiogenesis promoted by YKL-40 in a variety of diseases.

  14. Hydrolysis and Sulfation Pattern Effects on Release of Bioactive Bone Morphogenetic Protein-2 from Heparin-Based Microparticles.

    Science.gov (United States)

    Tellier, Liane E; Miller, Tobias; McDevitt, Todd C; Temenoff, Johnna S

    2015-10-28

    Glycosaminoglycans (GAGs) such as heparin are promising materials for growth factor delivery due to their ability to efficiently bind positively charged growth factors including bone morphogenetic protein-2 (BMP-2) through their negatively charged sulfate groups. Therefore, the goal of this study was to examine BMP-2 release from heparin-based microparticles (MPs) after first, incorporating a hydrolytically degradable crosslinker and varying heparin content within MPs to alter MP degradation and second, altering the sulfation pattern of heparin within MPs to vary BMP-2 binding and release. Using varied MP formulations, it was found that the time course of MP degradation for 1 wt% heparin MPs was ~4 days slower than 10 wt% heparin MPs, indicating that MP degradation was dependent on heparin content. After incubating 100 ng BMP-2 with 0.1 mg MPs, most MP formulations loaded BMP-2 with ~50% efficiency and significantly more BMP-2 release (60% of loaded BMP-2) was observed from more sulfated heparin MPs (MPs with ~100% and 80% of native sulfation). Similarly, BMP-2 bioactivity in more sulfated heparin MP groups was at least four-fold higher than soluble BMP-2 and less sulfated heparin MP groups, as determined by an established C2C12 cell alkaline phosphatase (ALP) assay. Ultimately, the two most sulfated 10 wt% heparin MP formulations were able to efficiently load and release BMP-2 while enhancing BMP-2 bioactivity, making them promising candidates for future growth factor delivery applications.

  15. Removal of glycosaminoglycans from bovine granulosa cells contributes to increased binding of hydrogen-3 heparin

    Energy Technology Data Exchange (ETDEWEB)

    Ax, R.L.; Stodd, C.M.; Boehm, S.K.; Bellin, M.E.

    1986-02-01

    Granulosa cells from small or large bovine follicles were pretreated with enzymes that hydrolyze various glycosaminoglycans, and binding of (/sup 3/H)-heparin to the granulosa was measured. Binding of (/sup 3/H) heparin increased significantly after enzymatic pretreatments with chondroitinase ABC and fungal hyaluronidase, and similar results were obtained with granulosa from small and large follicles. No changes in binding of (/sup 3/H) heparin were detected after hydrolyses with chondroitinase AC and heparinase in either follicle size. Heparitinase, which hydrolyzes heparan sulfate, led to a significant 50% increase in binding of (/sup 3/H) heparin to granulosa from large follicles but was without effect in small follicles. These results suggest that the lower binding of (/sup 3/H) heparin, which has been reported with follicular enlargement, may be due to heparan sulfate occupying or obstructing binding sites for heparin on granulosa from large follicles.

  16. Heparin Interaction with the Primed Polymorphonuclear Leukocyte CD11b Induces Apoptosis and Prevents Cell Activation

    Directory of Open Access Journals (Sweden)

    Meital Cohen-Mazor

    2015-01-01

    Full Text Available Heparin is known to have anti-inflammatory effects, yet the mechanisms are not completely understood. In this study, we tested the hypothesis that heparin has a direct effect on activated polymorphonuclear leukocytes (PMNLs, changing their activation state, and can explain its anti-inflammatory effect. To test our hypothesis, we designed both in vitro and ex vivo studies to elucidate the mechanism by which heparin modulates PMNL functions and therefore the inflammatory response. We specifically tested the hypothesis that priming of PMNLs renders them more susceptible to heparin. Amplified levels of CD11b and increased rate of superoxide release manifested PMNL priming. Increase in cell priming resulted in a dose-dependent increase in heparin binding to PMNLs followed by augmented apoptosis. Blocking antibodies to CD11b inhibited heparin binding and abolished the apoptotic response. Moreover, heparin caused a significant dose-dependent decrease in the rate of superoxide release from PMNLs, which was blunted by blocking antibodies to CD11b. Altogether, this study shows that the interaction of heparin with the PMNL CD11b results in cell apoptosis and explains heparin’s anti-inflammatory effects.

  17. Optimization Solutions for Improving the Performance of the Parallel Reduction Algorithm Using Graphics Processing Units

    Directory of Open Access Journals (Sweden)

    Ion LUNGU

    2012-01-01

    Full Text Available In this paper, we research, analyze and develop optimization solutions for the parallel reduction function using graphics processing units (GPUs that implement the Compute Unified Device Architecture (CUDA, a modern and novel approach for improving the software performance of data processing applications and algorithms. Many of these applications and algorithms make use of the reduction function in their computational steps. After having designed the function and its algorithmic steps in CUDA, we have progressively developed and implemented optimization solutions for the reduction function. In order to confirm, test and evaluate the solutions' efficiency, we have developed a custom tailored benchmark suite. We have analyzed the obtained experimental results regarding: the comparison of the execution time and bandwidth when using graphic processing units covering the main CUDA architectures (Tesla GT200, Fermi GF100, Kepler GK104 and a central processing unit; the data type influence; the binary operator's influence.

  18. Heparin-based hydrogels with tunable sulfation & degradation for anti-inflammatory small molecule delivery.

    Science.gov (United States)

    Peng, Yifeng; Tellier, Liane E; Temenoff, Johnna S

    2016-08-16

    Sustained release of anti-inflammatory agents remains challenging for small molecule drugs due to their low molecular weight and hydrophobicity. Therefore, the goal of this study was to control the release of a small molecule anti-inflammatory agent, crystal violet (CV), from hydrogels fabricated with heparin, a highly sulfated glycosaminoglycan capable of binding positively-charged molecules such as CV. In this system, both electrostatic interactions between heparin and CV and hydrogel degradation were tuned simultaneously by varying the level of heparin sulfation and varying the amount of dithiothreitol within hydrogels, respectively. It was found that heparin sulfation significantly affected CV release, whereby more sulfated heparin hydrogels (Hep and Hep(-N)) released CV with near zero-order release kinetics (R-squared values between 0.96-0.99). Furthermore, CV was released more quickly from fast-degrading hydrogels than slow-degrading hydrogels, providing a method to tune total CV release between 5-15 days while maintaining linear release kinetics. In particular, N-desulfated heparin hydrogels exhibited efficient CV loading (∼90% of originally included CV), near zero-order CV release kinetics, and maintenance of CV bioactivity after release, making this hydrogel formulation a promising CV delivery vehicle for a wide range of inflammatory diseases.

  19. Morbidity associated with heparin therapy in spinal surgery patients with cardiovascular diseases

    International Nuclear Information System (INIS)

    Sawakami, Kimihiko; Ishikawa, Seiichi; Ito, Takui

    2011-01-01

    The objectives of this study were to investigate morbidity associated with heparin therapy in spinal surgery patients. The management of patients on anticoagulant therapy who undergo spinal surgery is becoming a common clinical problem. Although guidelines for the management of gastrointestinal endoscopy patients on heparin therapy have been published, spinal surgery may lead to specific complications, especially because of heparin therapy. However, only few studies have examined the clinical significance of heparin therapy in spinal surgery patients. The subjects of this study were 116 consecutive patients who were on anticoagulant or antiplatelet therapy. This says that all of the patients were receiving heparin or another anticoagunt. The patients were divided into 2 groups: a group that received heparin therapy before and after surgery (H group, n=25) and a group that did not receive heparin therapy (NH group, n=91). The results of clinical examinations and magnetic resonance imaging (MRI) in the 2 groups were compared. There were no significant differences between the 2 groups in baseline data. Comorbidities in both groups included valvular heart disease, atrial fibrillation, angina pectoris/myocardial infarction, and cerebral infarction. Mean intraoperative and postoperative blood loss in the H group were 324 ml and 536 ml, respectively, and the corresponding values in the NH group were 431 ml and 449 ml, respectively. MRI of all patients was performed within 10 days after surgery and T2-weighted images in the axial plane were examined for evidence of an epidural hematoma. Although the proportion of patients with an epidural hematoma, detected by MRI was higher in the H group than in the NH group (71% vs. 64%), none of the patients in either group required revision surgery because of intolerable pain or muscle weakness. Thrombocytopenia and skin necrosis were observed as complications of the heparin therapy in 1 patient in the H group (4%). The rate of

  20. How much heparin do we really need to go on pump? A rethink of current practices.

    LENUS (Irish Health Repository)

    Shuhaibar, M N

    2012-02-03

    OBJECTIVES: Patients undergoing myocardial revascularisation using extracorporeal circulation require heparin anticoagulation. We aimed to evaluate the effect of reducing heparin dosage on target activated clotting time (ACT) and postoperative blood loss. METHODS: In a prospective randomised trial, 195 patients undergoing isolated primary CABG were randomised into four groups A, B, C, and D receiving an initial heparin dosage of 100, 200, 250 and 300 iu\\/kg, respectively. Extra incremental heparin (50 iu\\/kg) was added if required to achieve a target ACT of 480 s before initiating cardiopulmonary bypass. Postoperative blood loss was measured from the time of heparin reversal to drain removal 24h later. RESULTS: Target ACT was achieved in 0, 63, 68.3 and 82.4% of patients in groups A, B, C and D, respectively, after the initial dose of heparin. In group B, of those not achieving target act a single increment of heparin was sufficient to achieve target ACT in further 18.6%. The mean ACT after the initial dose in groups B, C and D was 482.9, 519 and 588 s, respectively (P<0.05). Postoperative blood loss in millilitre per kilogram was directly proportional to preoperative heparin dose. CONCLUSIONS: Patients receiving lower dose of heparin has lower postoperative blood loss. Of those achieving the target ACT, group B was significantly the closest to the target ACT. A starting dose of 200 iu\\/kg of heparin and if necessary one 50 iu\\/kg increment achieved target ACT in 81.5% of patients. The added benefit of significant drop in postoperative blood loss is evident.

  1. Development and evaluation of thermal model reduction algorithms for spacecraft

    Science.gov (United States)

    Deiml, Michael; Suderland, Martin; Reiss, Philipp; Czupalla, Markus

    2015-05-01

    This paper is concerned with the topic of the reduction of thermal models of spacecraft. The work presented here has been conducted in cooperation with the company OHB AG, formerly Kayser-Threde GmbH, and the Institute of Astronautics at Technische Universität München with the goal to shorten and automatize the time-consuming and manual process of thermal model reduction. The reduction of thermal models can be divided into the simplification of the geometry model for calculation of external heat flows and radiative couplings and into the reduction of the underlying mathematical model. For simplification a method has been developed which approximates the reduced geometry model with the help of an optimization algorithm. Different linear and nonlinear model reduction techniques have been evaluated for their applicability in reduction of the mathematical model. Thereby the compatibility with the thermal analysis tool ESATAN-TMS is of major concern, which restricts the useful application of these methods. Additional model reduction methods have been developed, which account to these constraints. The Matrix Reduction method allows the approximation of the differential equation to reference values exactly expect for numerical errors. The summation method enables a useful, applicable reduction of thermal models that can be used in industry. In this work a framework for model reduction of thermal models has been created, which can be used together with a newly developed graphical user interface for the reduction of thermal models in industry.

  2. The Effect of Low Molecular Weight Heparins on Fracture Healing.

    Science.gov (United States)

    Kapetanakis, Stylianos; Nastoulis, Evangelos; Demesticha, Theano; Demetriou, Thespis

    2015-01-01

    Venous Thromboembolism is a serious complication in the trauma patient. The most commonly studied and used anticoagulant treatment in prophylaxis of thrombosis is heparin. The prolonged use of unfractionated heparin has been connected with increased incidence of osteoporotic fractures. Low molecular-weight-heparins (LMWHs) have been the golden rule in antithrombotic therapy during the previous two decades as a way to overcome the major drawbacks of unfractioned heparin. However there are few studies reporting the effects of LMWHs on bone repair after fractures. This review presents the studies about the effects of LMWHs on bone biology (bone cells and bone metabolism) and underlying the mechanisms by which LMWHs may impair fracture healing process. The authors' research based on literature concluded that there are no facts and statistics for the role of LMWHs on fracture healing process in humans and the main body of evidence of their role comes from in vitro and animal studies. Further large clinical studies designed to compare different types of LMWHs, in different dosages and in different patient or animal models are needed for exploring the effects of LMWHs on fracture healing process.

  3. Heparin-Induced Cardiac Tamponade and Life-Threatening Hyperkalemia in a Patient with Chronic Hemodialysis

    Directory of Open Access Journals (Sweden)

    Ho-Ming Su

    2005-03-01

    Full Text Available Heparin, a commonly used anticoagulant agent, is frequently used in patients undergoing hemodialysis. As with most medications, heparin has a significant side effect profile. Two of its most important side effects, major bleeding and hyperkalemia, may be devastating without immediate diagnosis and treatment. Major bleeding such as gastrointestinal, genitourinary or intracranial bleeding is occasionally encountered and rarely neglected. However, heparin-induced cardiac tamponade is rarely encountered and may be easily overlooked. Another side effect, heparin-induced hyperkalemia, an unusual but well-described side effect, is frequently forgotten until life-threatening arrhythmia has occurred. We report a case involving a 40-year-old male patient with uremia, who had received heparin for 10 days for deep vein thrombosis in the left lower extremity. Hemopericardium with cardiac tamponade and life-threatening hyperkalemia were both noted in this patient.

  4. Heparinization of alimentation solutions administered through peripheral veins in premature infants: a controlled study.

    Science.gov (United States)

    Alpan, G; Eyal, F; Springer, C; Glick, B; Goder, K; Armon, J

    1984-09-01

    A randomized controlled study was done to determine whether the addition of heparin (1 U/mL) to peripheral intravenous alimentation solutions would affect the incidence of phlebitis and duration of patency of intravenous catheters in premature infants. Twenty-two-gauge Teflon catheters were uniformly used. One hundred five catheters infused with heparin were placed in 13 infants, and 122 catheters were placed in the control group of 13 infants. The time, nature, and incidence of complications were noted for each infusion site. Infusion of heparin was found to double the duration of patency of intravenous catheters and to reduce significantly the incidence of phlebitis. No complications related to the administration of heparin were noted. Heparinization of intravenous alimentation solutions should therefore be considered in premature infants as a means of reducing the work load and incidence of complications associated with peripheral lines.

  5. Dosimetric Evaluation of Metal Artefact Reduction using Metal Artefact Reduction (MAR) Algorithm and Dual-energy Computed Tomography (CT) Method

    Science.gov (United States)

    Laguda, Edcer Jerecho

    Purpose: Computed Tomography (CT) is one of the standard diagnostic imaging modalities for the evaluation of a patient's medical condition. In comparison to other imaging modalities such as Magnetic Resonance Imaging (MRI), CT is a fast acquisition imaging device with higher spatial resolution and higher contrast-to-noise ratio (CNR) for bony structures. CT images are presented through a gray scale of independent values in Hounsfield units (HU). High HU-valued materials represent higher density. High density materials, such as metal, tend to erroneously increase the HU values around it due to reconstruction software limitations. This problem of increased HU values due to metal presence is referred to as metal artefacts. Hip prostheses, dental fillings, aneurysm clips, and spinal clips are a few examples of metal objects that are of clinical relevance. These implants create artefacts such as beam hardening and photon starvation that distort CT images and degrade image quality. This is of great significance because the distortions may cause improper evaluation of images and inaccurate dose calculation in the treatment planning system. Different algorithms are being developed to reduce these artefacts for better image quality for both diagnostic and therapeutic purposes. However, very limited information is available about the effect of artefact correction on dose calculation accuracy. This research study evaluates the dosimetric effect of metal artefact reduction algorithms on severe artefacts on CT images. This study uses Gemstone Spectral Imaging (GSI)-based MAR algorithm, projection-based Metal Artefact Reduction (MAR) algorithm, and the Dual-Energy method. Materials and Methods: The Gemstone Spectral Imaging (GSI)-based and SMART Metal Artefact Reduction (MAR) algorithms are metal artefact reduction protocols embedded in two different CT scanner models by General Electric (GE), and the Dual-Energy Imaging Method was developed at Duke University. All three

  6. Effects of heparin on platelet aggregation and release and thromboxane A2 production

    International Nuclear Information System (INIS)

    Mohammad, S.F.; Anderson, W.H.; Smith, J.B.; Chuang, H.Y.; Mason, R.G.

    1981-01-01

    Heparin, when added to citrated platelet-rich plasma (PRP), caused potentiation of platelet aggregation and the release reaction induced by the aggregating agents adenosine diphosphate (ADP), arachidonic acid, collagen, and epinephrine. At low concentrations (4.7 x 10(-5) M) arachidonic acid failed to cause aggregation of platelets in citrated PRP. However, in the presence of heparin, the same concentration of arachidonic acid caused aggregation. Examination of PRP for the presence of thromboxane A2 (TxA2) by use of a bioassay revealed that heparin also stimulated release of TxA2. This finding indicated that platelets released more TxA2 when they were challenged by low concentrations of arachidonic acid in the presence of heparin than in its absence. Platelets were labeled with 3 H-arachidonic acid and 14 C-serotonin, and attempts were made to determine whether heparin stimulated the platelet release reaction first with subsequent increased production of TxA2, or alternatively, whether heparin stimulated TxA2 production first with subsequent enhancement of the release reaction. In view of the demonstrated simultaneous release of 14 C-serotonin and 3 H-arachidonic acid metabolites, it appeared that either release of 14 C and 3 H occurs concurrently or, even if one of these events is dependent on the other, both events take place in rapid succession. Timed sequential studies revealed that in the presence of arachidonic acid, the addition of heparin hastened the apparently simultaneous release of both 14 C and 3 H

  7. Increased accuracy in heparin and protamine administration decreases bleeding: a pilot study

    DEFF Research Database (Denmark)

    Runge, Marx; Møller, Christian H; Steinbrüchel, Daniel A

    2009-01-01

    Three to 5 percent of the patients undergoing cardiac surgery are reoperated because of bleeding. When a surgical cause can be excluded, heparin/protamine mismatch may be considered. Insufficient reversal of heparin and overdosing of protamine may cause postoperative bleeding. The purpose......). A reduced number of patients needed blood transfusions in the RxDx group, although this was not statistically significant (19% vs. 38%, respectively; p = .13). Initial heparin dose was significantly reduced in the RxDx group (250 mg; range, 100-375 mg) compared with the control group (300 mg; range, 200...

  8. Elimination of heparin interference during microarray processing of fresh and biobank-archived blood samples.

    Science.gov (United States)

    Hebels, Dennie G A J; van Herwijnen, Marcel H M; Brauers, Karen J J; de Kok, Theo M C M; Chalkiadaki, Georgia; Kyrtopoulos, Soterios A; Kleinjans, Jos C S

    2014-07-01

    In the context of environmental health research, biobank blood samples have recently been identified as suitable for high-throughput omics analyses enabling the identification of new biomarkers of exposure and disease. However, blood samples containing the anti-coagulant heparin could complicate transcriptomic analysis because heparin may inhibit RNA polymerase causing inefficient cRNA synthesis and fluorophore labelling. We investigated the inhibitory effect of heparin and the influence of storage conditions (0 or 3 hr bench times, storage at room temperature or -80°C) on fluorophore labelling in heparinized fresh human buffy coat and whole blood biobank samples during the mRNA work-up protocol for microarray analysis. Subsequently, we removed heparin by lithium chloride (LiCl) treatment and performed a quality control analysis of LiCl-treated biobank sample microarrays to prove their suitability for downstream data analysis. Both fresh and biobank samples experienced varying degrees of heparin-induced inhibition of fluorophore labelling, making most samples unusable for microarray analysis. RNA derived from EDTA and citrate blood was not inhibited. No effect of bench time was observed but room temperature storage gave slightly better results. Strong correlations were observed between original blood sample RNA yield and the amount of synthesized cRNA. LiCl treatment restored sample quality to normal standards in both fresh and biobank samples and the previously identified correlations disappeared. Microarrays hybridized with LiCl-treated biobank samples were of excellent quality with no identifiable influence of heparin. We conclude that, to obtain high quality results, in most cases heparin removal is essential in blood-derived RNA samples intended for microarray analysis. Copyright © 2014 Wiley Periodicals, Inc.

  9. Investigation of a Potential Protective Mechanism Against Heparin-Induced Thrombocytopenia in Patients on Chronic Intermittent Hemodialysis

    Science.gov (United States)

    Tanhehco, Yvette C.; Cuker, Adam; Rudnick, Michael; Sachais, Bruce S.

    2015-01-01

    BACKGROUND Heparin-induced thrombocytopenia (HIT) develops as a result of platelet (PLT) activation by anti-platelet factor 4 (PF4)/heparin complex antibodies. Despite repeated exposure to heparin, patients undergoing chronic intermittent hemodialysis (HD) rarely develop HIT. We investigated the possibility that HD decreases/removes PF4 from PLT surfaces and/or plasma, thereby disfavoring immune complex formation as a mechanism of protection against HIT. MATERIALS AND METHODS We enrolled 20 patients undergoing chronic HD at the Penn Presbyterian Medical Center. Blood samples were drawn before, during and after treatment in the presence and absence of heparin. PF4, PF4/heparin antibody, heparin, and P-selectin levels were measured. RESULTS No patients demonstrated clinical symptoms of HIT. PLT surface PF4 levels decreased and plasma PF4 levels increased concurrently with increase in plasma heparin concentration. In the absence of heparin, PLT surface and plasma PF4 levels were unchanged. Anti-PF4/heparin antibodies, which were non-functional by the serotonin release assay, were detectable in 8 patients. PLT surface P-selectin levels did not change during treatment. CONCLUSIONS Removal of PLT surface and/or plasma PF4 as a mechanism of protection against HIT in patients undergoing HD is not supported by the results of our study, although the transient decrease in PLT surface PF4 in the presence of large amounts of heparin remains a candidate mechanism. The small sample size, single type of dialyzer membrane, and early sampling time points may have led to the inability to detect changes in PF4 levels. Future studies should explore other potential protective mechanisms. PMID:23305841

  10. Relationship of nonreturn rates of dairy bulls to binding affinity of heparin to sperm

    International Nuclear Information System (INIS)

    Marks, J.L.; Ax, R.L.

    1985-01-01

    The binding of the glycosaminoglycan [ 3 H] heparin to bull spermatozoa was compared with nonreturn rates of dairy bulls. Semen samples from five bulls above and five below an average 71% nonreturn rate were used. Samples consisted of first and second ejaculates on a single day collected 1 d/wk for up to 5 consecutive wk. Saturation binding assays using [ 3 H] heparin were performed to quantitate the binding characteristics of each sample. Scatchard plot analyses indicated a significant difference in the binding affinity for [ 3 H] heparin between bulls of high and low fertility. Dissociation constants were 69.0 and 119.3 pmol for bulls of high and low fertility, respectively. In contrast, the number of binding sites for [ 3 H] heparin did not differ significantly among bulls. Differences in binding affinity of [ 3 H] heparin to bull sperm might be used to predict relative fertility of dairy bulls

  11. THE WASTE REDUCTION (WAR) ALGORITHM: ENVIRONMENTAL IMPACTS, ENERGY CONSUMPTION, AND ENGINEERING ECONOMICS

    Science.gov (United States)

    A general theory known as the WAste Reduction (WAR) algorithm has been developed to describe the flow and the generation of potential environmental impact through a chemical process. This theory defines potential environmental impact indexes that characterize the generation and t...

  12. Simple and Efficient Purification of Recombinant Proteins Using the Heparin-Binding Affinity Tag.

    Science.gov (United States)

    Jayanthi, Srinivas; Gundampati, Ravi Kumar; Kumar, Thallapuranam Krishnaswamy Suresh

    2017-11-01

    Heparin, a member of the glycosaminoglycan family, is known to interact with more than 400 different types of proteins. For the past few decades, significant progress has been made to understand the molecular details involved in heparin-protein interactions. Based on the structural knowledge available from the FGF1-heparin interaction studies, we have designed a novel heparin-binding peptide (HBP) affinity tag that can be used for the simple, efficient, and cost-effective purification of recombinant proteins of interest. HBP-tagged fusion proteins can be purified by heparin Sepharose affinity chromatography using a simple sodium chloride gradient to elute the bound fusion protein. In addition, owing to the high density of positive charges on the HBP tag, recombinant target proteins are preferably expressed in their soluble forms. The purification of HBP-fusion proteins can also be achieved in the presence of chemical denaturants, including urea. Additionally, polyclonal antibodies raised against the affinity tag can be used to detect HBP-fused target proteins with high sensitivity. © 2017 by John Wiley & Sons, Inc. Copyright © 2017 John Wiley & Sons, Inc.

  13. Preparation and characterization of chitosan-heparin composite matrices for blood contacting tissue engineering

    International Nuclear Information System (INIS)

    He Qing; Gong Kai; Gong Yandao; Zhang Xiufang; Ao Qiang; Zhang Lihai; Hu Min

    2010-01-01

    Chitosan has been widely used for biomaterial scaffolds in tissue engineering because of its good mechanical properties and cytocompatibility. However, the poor blood compatibility of chitosan has greatly limited its biomedical utilization, especially for blood contacting tissue engineering. In this study, we exploited a polymer blending procedure to heparinize the chitosan material under simple and mild conditions to improve its antithrombogenic property. By an optimized procedure, a macroscopically homogeneous chitosan-heparin (Chi-Hep) blended suspension was obtained, with which Chi-Hep composite films and porous scaffolds were fabricated. X-ray photoelectron spectroscopy and sulfur elemental analysis confirmed the successful immobilization of heparin in the composite matrices (i.e. films and porous scaffolds). Toluidine blue staining indicated that heparin was distributed homogeneously in the composite matrices. Only a small amount of heparin was released from the matrices during incubation in normal saline for 10 days. The composite matrices showed improved blood compatibility, as well as good mechanical properties and endothelial cell compatibility. These results suggest that the Chi-Hep composite matrices are promising candidates for blood contacting tissue engineering.

  14. Laboratory tests for identification or exclusion of heparin induced thrombocytopenia: HIT or miss?

    Science.gov (United States)

    Favaloro, Emmanuel J

    2018-02-01

    Heparin induced thrombocytopenia (HIT) is a potentially fatal condition that arises subsequent to formation of antibodies against complexes containing heparin, usually platelet-factor 4-heparin ("anti-PF4-heparin"). Assessment for HIT involves both clinical evaluation and, if indicated, laboratory testing for confirmation or exclusion, typically using an initial immunological assay ("screening"), and only if positive, a secondary functional assay for confirmation. Many different immunological and functional assays have been developed. The most common contemporary immunological assays comprise enzyme-linked immunosorbent assay [ELISA], chemiluminescence, lateral flow, and particle gel techniques. The most common functional assays measure platelet aggregation or platelet activation events (e.g., serotonin release assay; heparin-induced platelet activation (HIPA); flow cytometry). All assays have some sensitivity and specificity to HIT antibodies, but differ in terms of relative sensitivity and specificity for pathological HIT, as well as false negative and false positive error rate. This brief article overviews the different available laboratory methods, as well as providing a suggested approach to diagnosis or exclusion of HIT. © 2017 Wiley Periodicals, Inc.

  15. Heparin-Induced Thrombocytopenia in a Patient with Essential Thrombocythemia: A Case Based Update

    Directory of Open Access Journals (Sweden)

    Edva Noel

    2015-01-01

    Full Text Available Vascular thrombosis is a common clinical feature of both essential thrombocythemia (ET and heparin-induced thrombocytopenia (HIT. The development of HIT in a patient with ET is rare and underrecognized. We report the case of a 77-year-old woman with preexisting ET, who was admitted with acute coronary syndrome, and IV heparin was started. She was exposed to unfractionated heparin (UFH 5 days prior to this admission. Decrease in platelet count was noted, and HIT panel was sent. Heparin was discontinued. Patient developed atrial fibrillation, and Dabigatran was started. On day three, patient also developed multiple tiny cerebral infarctions and acute right popliteal DVT. On day ten of admission, HIT panel was positive, and Dabigatran was changed to Lepirudin. Two days later, Lepirudin was also discontinued because patient developed pseudoaneurysm on the right common femoral artery at the site of cardiac catheterization access. A progressive increase in the platelet count was noted after discontinuing heparin. Physicians should be aware of the coexistence of HIT and ET, accompanied challenges of the prompt diagnosis, and initiation of appropriate treatment.

  16. Heparin interferes with the radioenzymatic and homogeneous enzyme immunoassays for aminoglycosides

    International Nuclear Information System (INIS)

    Krogstad, D.J.; Granich, G.G.; Murray, P.R.; Pfaller, M.A.; Valdes, R.

    1981-01-01

    Heparin interferes with measurement of aminoglycosides in serum by biological, radioenzymatic, and homogeneous enzyme immunoassay techniques, but not with radioimmunoassay. At concentrations greater than or equal to 10 5 and greater than or equal to 3 X 10 6 USP units/L, respectively, it interferes with the radioenzymatic assay by inhibiting the gentamicin 3-acetyltransferase and kanamycin 6'-acetyltransferase enzymes used in the assay. It interferes with the homogeneous enzyme immunoassays for gentamicin and tobramycin (at concentrations greater than or equal to 10 5 and greater than or equal to10 4 USP units/L, respectively), but not with the commercially available homogeneous enzyme immunoassays for other drugs. Heparin interference with the homogeneous enzyme immunoassay for aminoglycosides requires both the heparin polyanion and glucose-6-phosphate dehydrogenase bound to a cationic aminoglycoside. This interference can be reproduced with dextran sulfate (but not dextran), and does not occur with free enzyme (glucose-6-phosphate dehydrogenase) alone. Heparin interference with these two assays and at concentrations that may be present in intravenous infusions or in seriously underfilled blood-collection tubes is described

  17. Preparation of Low Molecular Weight Heparin by Microwave Discharge Electrodeless Lamp/TiO2 Photo-Catalytic Reaction.

    Science.gov (United States)

    Lee, Do-Jin; Kim, Byung Hoon; Kim, Sun-Jae; Kim, Jung-Sik; Lee, Heon; Jung, Sang-Chul

    2015-01-01

    An MDEL/TiO2 photo-catalyst hybrid system was applied, for the first time, for the production of low molecular weight heparin. The molecular weight of produed heparin decreased with increasing microwave intensity and treatment time. The abscission of the chemical bonds between the constituents of heparin by photo-catalytic reaction did not alter the characteristics of heparin. Formation of by-products due to side reaction was not observed. It is suggested that heparin was depolymerized by active oxygen radicals produced during the MDEL/TiO2 photo-chemical reaction.

  18. Cost-utility of enoxaparin compared with unfractionated heparin in unstable coronary artery disease

    Directory of Open Access Journals (Sweden)

    Milne Ruairidh

    2001-10-01

    Full Text Available Abstract Background Low molecular weight heparins hold several advantages over unfractionated heparin including convenience of administration. Enoxaparin is one such heparin licensed in the UK for use in unstable coronary artery disease (unstable stable angina and non-Q wave myocardial infarction. In these patients, two large randomised controlled trials and their meta-analysis showed small benefits for enoxaparin over unfractionated heparin at 30–43 days and potentially at one year. We found no relevant published full economic evaluations, only cost studies, one of which was conducted in the UK. The other studies, from the US, Canada and France, are difficult to interpret since their resource use and costs may not reflect UK practice. Methods We aimed to compare the benefits and costs of short-term treatment (two to eight days with enoxaparin and unfractionated heparin in unstable coronary artery disease. We used published data sources to estimate the incremental cost per quality adjusted life year (QALY, adopting a NHS perspective and using 1998 prices. Results The base case was a 0.013 QALY gain and net cost saving of £317 per person treated with enoxaparin instead of unfractionated heparin. All but one sensitivity analysis showed net savings and QALY gains, the exception (the worst case being a cost per QALY of £3,305. Best cases were a £495 saving and 0.013 QALY gain, or a £317 saving and 0.014 QALY gain per person. Conclusions Enoxaparin appears cost saving compared with unfractionated heparin in patients with unstable coronary artery disease. However, cost implications depend on local revascularisation practice.

  19. Heparan sulfate C5-epimerase is essential for heparin biosynthesis in mast cells.

    Science.gov (United States)

    Feyerabend, Thorsten B; Li, Jin-Ping; Lindahl, Ulf; Rodewald, Hans-Reimer

    2006-04-01

    Biosynthesis of heparin, a mast cell-derived glycosaminoglycan with widespread importance in medicine, has not been fully elucidated. In biosynthesis of heparan sulfate (HS), a structurally related polysaccharide, HS glucuronyl C5-epimerase (Hsepi) converts D-glucuronic acid (GlcA) to L-iduronic acid (IdoA) residues. We have generated Hsepi-null mouse mutant mast cells, and we show that the same enzyme catalyzes the generation of IdoA in heparin and that 'heparin' lacking IdoA shows a distorted O-sulfation pattern.

  20. Heparin-induced increase in serum levels of aminotranferases. A controlled clinical trial.

    Science.gov (United States)

    Nielsen, H K; Husted, S E; Koopmann, H D; Fasting, H; Simonsen, O; Andersen, K; Husegaard, H C; Petersen, T K

    1984-01-01

    Sixty-four patients over the age of 40 years, undergoing elective surgery of at least one hour's duration, were randomized to treatment with either a thromboembolic deterrent ( TED ) stocking (Kendall Co.) or subcutaneous low-dose heparin 5 000 IU every 12 hours. Serum levels of alanine aminotransferase (S-ALAT), aspartate aminotransferase (S-ASAT), gamma-glutamyl transpeptidase (S-gamma-GT) and alkaline phosphatase (S-ALP) were measured. S-ALAT increased significantly on the 5th and 10th postoperative day, from 27 +/- 2 (x +/- SE) to 40 +/- 4 (p less than 0.01) and 55 +/- 7 U/l (p less than 0.001), respectively, in the heparin group and was significantly higher in the heparin than in the TED group both on the 5th (p less than 0.01) and 10th (p less than 0.05) postoperative day. S-ASAT and S-gamma-GT increased significantly during heparin treatment, but did not differ significantly from the values of the TED group. No change in S-ALP was registered in either group. It is concluded that prophylactic treatment with low-dose heparin induces a significant increase in S-aminotransferase levels, especially in S-ALAT. The phenomenon has profound differential diagnostic implications in conditions such as pulmonary embolism and acute myocardial infarction.

  1. [Heparin-induced thrombocytopenia developed during the acute phase after left upper lobectomy for lung cancer].

    Science.gov (United States)

    Mitomo, Hideki; Miyamoto, Akira; Tabata, Toshiharu; Sugawara, Takafumi; Yabuki, Hiroshi; Fujimura, Shigefumi

    2014-12-01

    Heparin-induced thrombocytopenia (HIT) is a serious adverse effect of heparin administration. This must not be rarely encountered but is not often reported in Japan compared to Western countries. A 68-year-old woman underwent left upper lobectomy for lung cancer. Low-dose unfractionated heparin was administrated to prevent thromboembolism after the operation. Two days later, sudden dyspnea appeared and ultracardiosonography showing an extensive thromboembolus from the main trunk to both main branches of pulmonary artery indicated pulmonary embolization. After the establishment of percutaneous cardiopulmonary support (PCPS) support, the embolus was removed by emergent open heart surgery. However, despite further unfractionated heparin administration following embolization surgery, other thrombus was identified in both the bi-lateral internal jagular veins and inferior vena cava by ultrasonography and contrast computed tomography( CT). Her platelet count was decreased gradually despite platelet transfusion. Plate factor 4( PF4) antibody against heparin in her blood examination was found, and HIT II was diagnosed. Discontinuation of unfractionated heparin and administration of antithrombin agent improved platelet count, and no additional embolization was identified.

  2. Alternative method for determination of contaminated heparin using chiral recognition.

    Science.gov (United States)

    Szekely, J; Collins, M; Currie, C A

    2014-05-15

    Since 2008 a significant amount of work has focused on the development of methods to analyze contaminated heparin. This work focuses on utilizing heparin's ability to serve as a chiral selector as a means for determining contamination. Specifically, the effect of contamination on the separation of pheniramine and chloroquine enantiomers was explored. Separations were conducted using heparin contaminated with chondroitin sulfate at varying levels. For each pair of enantiomers, electrophoretic mobility and resolution were calculated. For pheniramine enantiomers, an increase in contamination leads to a decrease in the electrophoretic mobility and resolution. A linear relationship between contamination level and electrophoretic mobility of the pheniramine enantiomers was observed for the entire contamination range. A linear relationship was also found between contamination level and resolution of the enantiomers between 0 and 70 percent contamination. For the separation of chloroquine enantiomers, it was found that at low levels of contamination, the resolution of enantiomers was increased due to the secondary interaction between the chloroquine enantiomers and the chondroitin sulfate. Results of this study illustrate the potential of using chiral recognition as a means to determine heparin contamination as well as the improvement of the chiral resolution of chloroquine with the additional of low levels of chondroitin sulfate A. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. Preparation of tin -heparin complex to be applied for myocardial infarct diagnosis

    International Nuclear Information System (INIS)

    Badi, J. M.; Al-Azzawi, H. A.; Resen, H. M.; Abed, I. G.; Owiad, H.; Manji, A. N.

    2012-12-01

    Tin-heparin complex has been prepared (liquid form) to be labeled with technetium-99 can be applied for diagnosis of myocardial infarcts vascular diseases and deep vein thrombosis. The preparation contents are 0.1mg tin chloride dehydrate and 1250 1.U of heparin. The results of the pH effect on the labeling yield indicated that high percentage of labeling yield (96.1%) was obtained in the optimal pH (5.50). The obtained results showed that the quantity of reducing agent (tin chloride dehydrate) and chelating agent (heparin) has no effect on the labeling yield. Results of radio analytical studies by paper chromatography technique wear confirmed by data obtained by Gel chromatography column scanning techniques. These techniques showed the high labeling yield of the tin-heparin complex. The persistence of high labeling yield for 8 hours is a good indication for its stability and efficiency for radio diagnosis examination in nuclear medicine centers. (Author)

  4. Improved assay for measuring heparin binding to bull sperm

    International Nuclear Information System (INIS)

    Miller, D.J.; Ax, R.L.

    1988-01-01

    The binding of heparin to sperm has been used to study capacitation and to rank relative fertility of bulls. Previous binding assays were laborious, used 10 7 sperm per assay point, and required large amounts of radiolabeled heparin. A modified heparin-binding assay is described that used only 5 x 10 4 cells per incubation well and required reduced amounts of [ 3 H] heparin. The assay was performed in 96-well Millititer plates, enabling easy incubation and filtering. Dissociation constants and concentrations of binding sites did not differ if analyzed by Scatchard plots, Woolf plots, or by log-logit transformed weighted nonlinear least squares regression, except in the case of outliers. In such cases, Scatchard analysis was more sensitive to outliers. Nonspecific binding was insignificant using nonlinear logistic fit regression and a proportion graph. The effects were tested of multiple free-thawing of sperm in either a commercial egg yolk extender, 40 mM Tris buffer with 8% glycerol, or 40 mM Tris buffer without glycerol. Freeze-thawing in extender did not affect the dissociation constant or the concentration of binding sites. However, freeze-thawing three times in 40 mM Tris reduced the concentration of binding sites and lowered the dissociation constant (raised the affinity). The inclusion of glycerol in the 40 mM Tris did not significantly affect the estimated dissociation constant or the concentration of binding sites as compared to 40 mM Tris without glycerol

  5. PAPR Reduction in OFDM-based Visible Light Communication Systems Using a Combination of Novel Peak-value Feedback Algorithm and Genetic Algorithm

    Science.gov (United States)

    Deng, Honggui; Liu, Yan; Ren, Shuang; He, Hailang; Tang, Chengying

    2017-10-01

    We propose an enhanced partial transmit sequence technique based on novel peak-value feedback algorithm and genetic algorithm (GAPFA-PTS) to reduce peak-to-average power ratio (PAPR) of orthogonal frequency division multiplexing (OFDM) signals in visible light communication (VLC) systems(VLC-OFDM). To demonstrate the advantages of our proposed algorithm, we analyze the flow of proposed technique and compare the performances with other techniques through MATLAB simulation. The results show that GAPFA-PTS technique achieves a significant improvement in PAPR reduction while maintaining low bit error rate (BER) and low complexity in VLC-OFDM systems.

  6. Heparin binding domain of antithrombin III: Characterization using a synthetic peptide directed polyclonal antibody

    International Nuclear Information System (INIS)

    Smith, J.W.; Dey, B.; Knauer, D.J.

    1990-01-01

    Antithrombin III (ATIII) is a plasma-borne serine protease inhibitor that apparently forms covalent complexes with thrombin. The interaction between ATIII and thrombin is enhanced several thousandfold by the glycosaminoglycan, heparin. The authors have previously proposed that the heparin binding site of ATIII residues within a region extending from amino acid residues 114-156. Computer-assisted analysis of this region revealed the presence of a 22 amino acid domain (residues 124-145), part of which shows a strong potential for the formation of an amphipathic helix: hydrophobic on one face and highly positively charged on the other. In the presence studies, polyclonal antisera were generated against a synthetic peptide corresponding to residues 124-145 in native human ATIII. Affinity-purified IgG from these antisera, as well as monovalent Fab's derived from them, specifically blocked the binding of heparin to ATIII. Additionally, occupancy of the heparin binding site by these same monovalent and bivalent IgG's at least partially substituted for heparin, accelerating linkage formation between ATIII and thrombin. These results provide the first immunological evidence that region 124-145 is directly involved in the binding of heparin to ATIII and that an antibody-induced conformational change within this region can mediate ATIII activation

  7. High-throughput differentiation of heparin from other glycosaminoglycans by pyrolysis mass spectrometry.

    Science.gov (United States)

    Nemes, Peter; Hoover, William J; Keire, David A

    2013-08-06

    Sensors with high chemical specificity and enhanced sample throughput are vital to screening food products and medical devices for chemical or biochemical contaminants that may pose a threat to public health. For example, the rapid detection of oversulfated chondroitin sulfate (OSCS) in heparin could prevent reoccurrence of heparin adulteration that caused hundreds of severe adverse events including deaths worldwide in 2007-2008. Here, rapid pyrolysis is integrated with direct analysis in real time (DART) mass spectrometry to rapidly screen major glycosaminoglycans, including heparin, chondroitin sulfate A, dermatan sulfate, and OSCS. The results demonstrate that, compared to traditional liquid chromatography-based analyses, pyrolysis mass spectrometry achieved at least 250-fold higher sample throughput and was compatible with samples volume-limited to about 300 nL. Pyrolysis yielded an abundance of fragment ions (e.g., 150 different m/z species), many of which were specific to the parent compound. Using multivariate and statistical data analysis models, these data enabled facile differentiation of the glycosaminoglycans with high throughput. After method development was completed, authentically contaminated samples obtained during the heparin crisis by the FDA were analyzed in a blinded manner for OSCS contamination. The lower limit of differentiation and detection were 0.1% (w/w) OSCS in heparin and 100 ng/μL (20 ng) OSCS in water, respectively. For quantitative purposes the linear dynamic range spanned approximately 3 orders of magnitude. Moreover, this chemical readout was successfully employed to find clues in the manufacturing history of the heparin samples that can be used for surveillance purposes. The presented technology and data analysis protocols are anticipated to be readily adaptable to other chemical and biochemical agents and volume-limited samples.

  8. Data Reduction Algorithm Using Nonnegative Matrix Factorization with Nonlinear Constraints

    Science.gov (United States)

    Sembiring, Pasukat

    2017-12-01

    Processing ofdata with very large dimensions has been a hot topic in recent decades. Various techniques have been proposed in order to execute the desired information or structure. Non- Negative Matrix Factorization (NMF) based on non-negatives data has become one of the popular methods for shrinking dimensions. The main strength of this method is non-negative object, the object model by a combination of some basic non-negative parts, so as to provide a physical interpretation of the object construction. The NMF is a dimension reduction method thathasbeen used widely for numerous applications including computer vision,text mining, pattern recognitions,and bioinformatics. Mathematical formulation for NMF did not appear as a convex optimization problem and various types of algorithms have been proposed to solve the problem. The Framework of Alternative Nonnegative Least Square(ANLS) are the coordinates of the block formulation approaches that have been proven reliable theoretically and empirically efficient. This paper proposes a new algorithm to solve NMF problem based on the framework of ANLS.This algorithm inherits the convergenceproperty of the ANLS framework to nonlinear constraints NMF formulations.

  9. Reduction of metallic coil artefacts in computed tomography body imaging: effects of a new single-energy metal artefact reduction algorithm

    Energy Technology Data Exchange (ETDEWEB)

    Kidoh, Masafumi; Utsunomiya, Daisuke; Ikeda, Osamu; Tamura, Yoshitaka; Oda, Seitaro; Yuki, Hideaki; Nakaura, Takeshi; Hirai, Toshinori; Yamashita, Yasuyuki [Kumamoto University, Department of Diagnostic Radiology, Faculty of Life Sciences, Kumamoto (Japan); Funama, Yoshinori [Kumamoto University, Department of Medical Physics, Faculty of Life Sciences, Kumamoto (Japan); Kawano, Takayuki [Kumamoto University Graduate School, Department of Neurosurgery, Faculty of Life Sciences Research, Kumamoto (Japan)

    2016-05-15

    We evaluated the effect of a single-energy metal artefact reduction (SEMAR) algorithm for metallic coil artefact reduction in body imaging. Computed tomography angiography (CTA) was performed in 30 patients with metallic coils (10 men, 20 women; mean age, 67.9 ± 11 years). Non-SEMAR images were reconstructed with iterative reconstruction alone, and SEMAR images were reconstructed with the iterative reconstruction plus SEMAR algorithms. We compared image noise around metallic coils and the maximum diameters of artefacts from coils between the non-SEMAR and SEMAR images. Two radiologists visually evaluated the metallic coil artefacts utilizing a four-point scale: 1 = extensive; 2 = strong; 3 = mild; 4 = minimal artefacts. The image noise and maximum diameters of the artefacts of the SEMAR images were significantly lower than those of the non-SEMAR images (65.1 ± 33.0 HU vs. 29.7 ± 10.3 HU; 163.9 ± 54.8 mm vs. 10.3 ± 19.0 mm, respectively; P < 0.001). Better visual scores were obtained with the SEMAR technique (3.4 ± 0.6 vs. 1.0 ± 0.0, P < 0.001). The SEMAR algorithm significantly reduced artefacts caused by metallic coils compared with the non-SEMAR algorithm. This technique can potentially increase CT performance for the evaluation of post-coil embolization complications. (orig.)

  10. Reduction of metallic coil artefacts in computed tomography body imaging: effects of a new single-energy metal artefact reduction algorithm

    International Nuclear Information System (INIS)

    Kidoh, Masafumi; Utsunomiya, Daisuke; Ikeda, Osamu; Tamura, Yoshitaka; Oda, Seitaro; Yuki, Hideaki; Nakaura, Takeshi; Hirai, Toshinori; Yamashita, Yasuyuki; Funama, Yoshinori; Kawano, Takayuki

    2016-01-01

    We evaluated the effect of a single-energy metal artefact reduction (SEMAR) algorithm for metallic coil artefact reduction in body imaging. Computed tomography angiography (CTA) was performed in 30 patients with metallic coils (10 men, 20 women; mean age, 67.9 ± 11 years). Non-SEMAR images were reconstructed with iterative reconstruction alone, and SEMAR images were reconstructed with the iterative reconstruction plus SEMAR algorithms. We compared image noise around metallic coils and the maximum diameters of artefacts from coils between the non-SEMAR and SEMAR images. Two radiologists visually evaluated the metallic coil artefacts utilizing a four-point scale: 1 = extensive; 2 = strong; 3 = mild; 4 = minimal artefacts. The image noise and maximum diameters of the artefacts of the SEMAR images were significantly lower than those of the non-SEMAR images (65.1 ± 33.0 HU vs. 29.7 ± 10.3 HU; 163.9 ± 54.8 mm vs. 10.3 ± 19.0 mm, respectively; P < 0.001). Better visual scores were obtained with the SEMAR technique (3.4 ± 0.6 vs. 1.0 ± 0.0, P < 0.001). The SEMAR algorithm significantly reduced artefacts caused by metallic coils compared with the non-SEMAR algorithm. This technique can potentially increase CT performance for the evaluation of post-coil embolization complications. (orig.)

  11. Coexistence of Antiphospholipid Syndrome and Heparin-Induced Thrombocytopenia in a Patient with Recurrent Venous Thromboembolism

    Directory of Open Access Journals (Sweden)

    Samuel Adediran

    2017-01-01

    Full Text Available Heparin-induced thrombocytopenia (HIT is a prothrombotic adverse drug reaction in which heparin forms complexes with platelet factor 4 forming neoantigens that are recognized by autoantibodies. Antiphospholipid syndrome (APS is similar to HIT in that it is mediated by autoantibodies that are also prothrombotic. We present a case of rare coexistence of antiphospholipid antibody syndrome and heparin-induced thrombocytopenia.

  12. In vitro effects of heparin and tissue factor pathway inhibitor on factor VII assays. possible implications for measurements in vivo after heparin therapy

    DEFF Research Database (Denmark)

    Bladbjerg, E-M; Larsen, L F; Ostergaard, P

    2000-01-01

    The coagulant activity of blood coagulation factor VII (FVII:C) can be lowered by changes in lifestyle and by therapeutic intervention, e.g. heparin infusion. The question is, however, whether FVII:C determined ex vivo is a valid measure of the FVII activity in vivo. We measured plasma FVII......:C, activated FVII (FVIIa), FVII protein (FVII:Ag), tissue factor pathway inhibitor (TFPI), triglycerides, and free fatty acids (FFA) before and 15 min after infusion of a bolus of unfractionated heparin (50 IU/kg body weight) in 12 healthy subjects. Additionally, we conducted in vitro experiments...

  13. N-acetyl-heparin attenuates acute lung injury caused by acid aspiration mainly by antagonizing histones in mice.

    Science.gov (United States)

    Zhang, Yanlin; Zhao, Zanmei; Guan, Li; Mao, Lijun; Li, Shuqiang; Guan, Xiaoxu; Chen, Ming; Guo, Lixia; Ding, Lihua; Cong, Cuicui; Wen, Tao; Zhao, Jinyuan

    2014-01-01

    Acute lung injury (ALI) is the leading cause of death in intensive care units. Extracellular histones have recently been recognized to be pivotal inflammatory mediators. Heparin and its derivatives can bind histones through electrostatic interaction. The purpose of this study was to investigate 1) the role of extracellular histones in the pathogenesis of ALI caused by acid aspiration and 2) whether N-acetyl-heparin (NAH) provides more protection than heparin against histones at the high dose. ALI was induced in mice via intratracheal instillation of hydrochloric acid (HCl). Lethality rate, blood gas, myeloperoxidase (MPO) activity, lung edema and pathological changes were used to evaluate the degree of ALI. Heparin/NAH was administered intraperitoneally, twice a day, for 3 days or until death. Acid aspiration caused an obvious increase in extracellular histones. A significant correlation existed between the concentration of HCl aspirated and the circulating histones. Heparin/NAH (10 mg/kg) improved the lethality rate, blood gas, MPO activity, lung edema and pathological score. At a dose of 20 mg/kg, NAH still provided protection, however heparin tended to aggravate the injury due to hemorrhagic complications. The specific interaction between heparin and histones was verified by the binding assay. In summary, high levels of extracellular histones can be pathogenic in ALI caused by acid aspiration. By neutralizing extracellular histones, heparin/NAH can offer similar protection at the moderate doses. At the high dose, NAH provides better protection than heparin.

  14. Evidence for a saturable mechanism of disappearance of standard heparin in rabbits

    International Nuclear Information System (INIS)

    Boneu, B.; Caranobe, C.; Gabaig, A.M.; Dupouy, D.; Sie, P.; Buchanan, M.R.; Hirsh, J.

    1987-01-01

    This work demonstrates that after bolus intravenous injection standard heparin (SH) disappearance results from the combination of a saturable and a non saturable mechanism. Pharmacokinetics and pharmacodynamics of SH were studied by measuring the disappearance of increasing doses (5 - 500 anti-factor Xa U/kg) of 125 I-heparin and of its biological effects. CPM curves allowed the determination of the half lives of heparin according to the dose injected. The half lives were clearly dose dependent and reached a plateau over 100 anti-factor Xa U/kg. The complex curve which describes the amount of heparin cleared per time unit after any given dose has been resolved into its two components reflecting a saturable and a non saturable mechanism of disappearance. For the doses less than 100 anti-factor Xa U/kg the saturable mechanism was preeminent and the anti-factor Xa activity disappearance followed an exponential pattern; for the doses less than 100 anti-factor Xa U/kg the contribution of the non saturable mechanism becomes more important and the anti-factor Xa activity disappearance followed a concave-convex pattern. Further experiments showed that the heparin half life shortened as the circulating anti-factor Xa activity decreased; this phenomenon may explain the concave-convex pattern of the curve of the anticoagulant effect observed after injection of large doses of SH

  15. Analytical characterization of heparin by capillary zone electrophoresis with conductivity detection and polymeric buffer additives.

    Science.gov (United States)

    Mikus, Peter; Valásková, Iva; Havránek, Emil

    2004-11-15

    A capillary zone electrophoresis (CZE) method for the analytical characterization of intact (high-molecular-weight) heparin was developed. For the first time, a hydrodynamically closed CZE separation system with conductivity detector was used for the separation, detection and quantitation of this highly sulfated, linear polysaccharide. Glycine (25mM) adjusted to pH 9.0 by bis-Tris-propane served as the running electrolyte system. Polymeric additives, polyvinylpyrrolidone (PVP), dextran (DEX), were used to improve the separation selectivity as they strongly retarded the heparin macromolecule while they did not practically influence comigrating inorganic anions. The proposed electrophoretic method was successfully validated. It was convenient for the sensitive, simple, rapid and reproducible assay of heparin in raw materials and isotonic saline. Here, the use of the conductivity detector was advantageous as it allowed heparin to be analyzed without a sample pretreatment. The CZE method should be an alternative to the pharmacopoeial conventional gel electrophoresis having used in the quality control of heparin so far. In addition, it should be convenient to quantitative estimation of heparin present in a preparation used, e.g., as the chiral selector in CE separations.

  16. Heparin and insulin in the management of hypertriglyceridemia-associated pancreatitis: case series and literature review.

    Science.gov (United States)

    Kuchay, Mohammad Shafi; Farooqui, Khalid J; Bano, Tarannum; Khandelwal, Manoj; Gill, Harmandeep; Mithal, Ambrish

    2017-01-01

    Severe hypertriglyceridemia accounts for up to 7% of all cases of acute pancreatitis. Heparin and insulin activate lipoprotein lipase (LPL), thereby reducing plasma triglyceride levels. However, the safety and efficacy of heparin and insulin in the treatment of hypertriglyceridemia-associated acute pancreatitis have not been well established yet. We successfully used heparin and insulin as first-line therapy in four consecutive patients with acute pancreatitis secondary to hypertriglyceridemia. In a literature search, we revised almost all reports published to date of patients managed successfully with this combination. Heparin and insulin appear to be a safe, effective, and inexpensive first-line therapy for hypertriglyceridemia-associated acute pancreatitis.

  17. Prevention of fatal postoperative pulmonary embolism by low doses of heparin. An international multicentre trial.

    Science.gov (United States)

    1975-07-12

    The efficacy of low-dose heparin in preventing fatal postoperative pulmonary embolism has been investigated in a multicentre prospective randomised trial. 4121 patients over the age of forty years undergoing a variety of elective major surgical procedures were included in the trial; 2076 of these were in the control group and 2045 patients received heparin. The two groups were well matched for age, sex, weight, blood-group, and other factors which could predispose to the development of venous thromboembolism. 180 (4-4 %) patients died during the postoperative period, 100 in the control and 80 in the heparin group: 72% of deaths in the control and 66% in the heparin group had necropsy examination. 16 patients in the control group and 2 in the heparin group were found at necropsy to have died due to acute massive pulmonary embolism (P smaller than 0-005). In addition, emboli found at necropsy in 6 patients in the control group and 3 in the heparin group were considered either contributory to death or an incidental finding since death in these patients was attributed to other causes. Taking all pulmonary emboli together, the findings were again significant (P smaller than 0-005). Of 1292 patients in whom the 125-I-fibrinogen test was performed to detect deep-vein thrombosis (D.V.T.) 667 were in the control group and 625 in the heparin group. The frequency of isotopic D.V.T. was reduced from 24-6% in the control group 7-7% in the heparin group (P smaller 0-005). In 30 patients D.V.T. was detected at necropsy; 24 in the control and 6 in the heparin group (P smaller 0-005). 32 patients in the control group and 11 in the heparin group developed clinically diagnosed D.V.T. which was confirmed by venography (P smaller than 0-005). In addition, 24 patients in the control and 8 in the heparin group were treated for clinically suspected pulmonary emoblism. The difference in the number of patients requiring treatment for D.V.T. and/or pulmonary embolism in the two groups was

  18. Partial Transmit Sequence Optimization Using Improved Harmony Search Algorithm for PAPR Reduction in OFDM

    Directory of Open Access Journals (Sweden)

    Mangal Singh

    2017-12-01

    Full Text Available This paper considers the use of the Partial Transmit Sequence (PTS technique to reduce the Peak‐to‐Average Power Ratio (PAPR of an Orthogonal Frequency Division Multiplexing signal in wireless communication systems. Search complexity is very high in the traditional PTS scheme because it involves an extensive random search over all combinations of allowed phase vectors, and it increases exponentially with the number of phase vectors. In this paper, a suboptimal metaheuristic algorithm for phase optimization based on an improved harmony search (IHS is applied to explore the optimal combination of phase vectors that provides improved performance compared with existing evolutionary algorithms such as the harmony search algorithm and firefly algorithm. IHS enhances the accuracy and convergence rate of the conventional algorithms with very few parameters to adjust. Simulation results show that an improved harmony search‐based PTS algorithm can achieve a significant reduction in PAPR using a simple network structure compared with conventional algorithms.

  19. Bilateral adrenal haemorrhage associated with heparin-induced thrombocytopaenia during treatment of Fournier gangrene.

    Science.gov (United States)

    Tattersall, Timothy Lee; Thangasamy, Isaac A; Reynolds, Jamie

    2014-10-14

    We present a case of bilateral adrenal haemorrhage (BAH) associated with heparin-induced thrombocytopaenia (HIT) in a 61-year-old man admitted to hospital for the treatment of Fournier's gangrene. He presented to hospital with scrotal swelling and fever, and developed spreading erythaema and a gangrenous scrotum. His scrotum was surgically debrided and intravenous broad-spectrum antibiotics were administered. Unfractionated heparin was given postoperatively for venous thromboembolism prophylaxis. The patient deteriorated clinically 8-11 days postoperatively with delirium, chest pain and severe hypertension followed by hypotension and thrombocytopaenia. Abdominal CT scan revealed bilateral adrenal haemorrhage. Antibodies to the heparin-platelet factor 4 complex were present. HIT-associated BAH was diagnosed and heparin was discontinued. Intravenous bivalirudin and hydrocortisone were started, with rapid improvement in clinical status. BAH is a rare complication of HIT and should be considered in the postoperative patient with unexplained clinical deterioration. 2014 BMJ Publishing Group Ltd.

  20. Subtle differences in commercial heparins can have serious consequences for cardiopulmonary bypass patients: A randomized controlled trial.

    Science.gov (United States)

    Arsenault, Kyle A; Paikin, Jeremy S; Hirsh, Jack; Dale, Brian; Whitlock, Richard P; Teoh, Kevin; Young, Ed; Ginsberg, Jeffrey S; Weitz, Jeffrey I; Eikelboom, John W

    2012-10-01

    To compare the potency, reversibility, and perioperative bleeding risk of Hepalean with those of PPC heparin. Because in vitro testing failed to detect differences in the potency or protamine reversibility of the 2 heparin preparations, we conducted a parallel group, single-center, double-blind, randomized, controlled trial to compare the anticoagulant effects of Hepalean to those of PPC heparin in patients undergoing coronary artery bypass grafting with cardiopulmonary bypass. From June 1, 2011, to June 30, 2011, we randomly assigned 11 patients to receive PPC heparin and 10 to receive Hepalean. Despite similar initial doses of heparin, the median initial activated clotting time was numerically lower in the PPC heparin group than in the Hepalean group (median, 516.0 seconds; interquartile range, 481.0-633.0; vs median, 584.0 seconds, interquartile range, 520.0-629.0; P = .418). Those given PPC heparin required a greater total heparin dose (median, 46,000.0 U; interquartile range, 39,500.0-60,000.0 vs median, 34,500.0 U; interquartile range, 32,250.0-37,000.0; P = .011) and a greater dose of heparin per kilogram than those given Hepalean (median, 572.9 U/kg; interquartile range, 443.0-659.7 vs median, 401.1 U/kg; interquartile range, 400.0-419.4; P = .003). The key secondary results included an increased median total protamine dose (median, 600.0 mg; interquartile range, 550.0-700.0; vs median, 500.0 mg; interquartile range, 425.0-542.5; P = .026) and a trend toward increased chest tube output within 24 hours (median, 830.0 mL; interquartile range, 425.0-1135.0; vs median, 702.5 mL; interquartile range, 550.0-742.5; P = .324). PPC heparin use was associated with greater heparin and protamine dose requirements than Hepalean. These findings indicate that heparin preparations are not interchangeable and suggest that a direct comparison of the potency with the brand in use is needed if a change is made to ensure that the agents exert similar anticoagulant

  1. Anticoagulation and endothelial cell behaviors of heparin-loaded graphene oxide coating on titanium surface

    Energy Technology Data Exchange (ETDEWEB)

    Pan, Chang-Jiang, E-mail: panchangjiang@hyit.edu.cn [Jiangsu Provincial Key Laboratory for Interventional Medical Devices, Huaiyin Institute of Technology, Huai' an 223003 (China); Pang, Li-Qun [Department of General Surgery, Huai' an First People' s Hospital, Nanjing Medical University, Huai' an 223300 (China); Gao, Fei [Zhejiang Zylox Medical Devices Co., Ltd., Hangzhou 310000 (China); Wang, Ya-Nan; Liu, Tao; Ye, Wei; Hou, Yan-Hua [Jiangsu Provincial Key Laboratory for Interventional Medical Devices, Huaiyin Institute of Technology, Huai' an 223003 (China)

    2016-06-01

    Owing to its unique physical and chemical properties, graphene oxide (GO) has attracted tremendous interest in many fields including biomaterials and biomedicine. The purpose of the present study is to investigate the endothelial cell behaviors and anticoagulation of heparin-loaded GO coating on the titanium surface. To this end, the titanium surface was firstly covered by the polydopamine coating followed by the deposition of the GO coating. Heparin was finally loaded on the GO coating to improve the blood compatibility. The results of attenuated total reflectance Fourier transform infrared spectroscopy (ATR-FTIR), Raman spectroscopy and X-ray photoelectron spectroscopy (XPS) indicated that the heparin-loaded GO coating was successfully created on the titanium surface. The scanning electron microscopy (SEM) images indicated that a relative uniform GO coating consisting of multilayer GO sheets was formed on the substrate. The hydrophilicity of the titanium surface was enhanced after the deposition of GO and further improved significantly by the loading heparin. The GO coating can enhance the endothelial cell adhesion and proliferation as compared with polydopamine coating and the blank titanium. Loading heparin on the GO coating can significantly reduce the platelet adhesion and prolong the activated partial thromboplastin time (APTT) while not influence the endothelial cell adhesion and proliferation. Therefore, the heparin-loaded GO coating can simultaneously enhance the cytocompatibility to endothelial cells and blood compatibility of biomaterials. Because the polydopamine coating can be easily prepared on most of biomaterials including polymer, ceramics and metal, thus the approach of the present study may open up a new window of promising an effective and efficient way to promote endothelialization and improve the blood compatibility of blood-contact biomedical devices such as intravascular stents. - Highlights: • Heparin-loaded graphene oxide coating was

  2. Functionalization of chitosan/poly(lactic acid-glycolic acid) sintered microsphere scaffolds via surface heparinization for bone tissue engineering.

    Science.gov (United States)

    Jiang, Tao; Khan, Yusuf; Nair, Lakshmi S; Abdel-Fattah, Wafa I; Laurencin, Cato T

    2010-06-01

    Scaffolds exhibiting biological recognition and specificity play an important role in tissue engineering and regenerative medicine. The bioactivity of scaffolds in turn influences, directs, or manipulates cellular responses. In this study, chitosan/poly(lactic acid-co-glycolic acid) (chitosan/PLAGA) sintered microsphere scaffolds were functionalized via heparin immobilization. Heparin was successfully immobilized on chitosan/PLAGA scaffolds with controllable loading efficiency. Mechanical testing showed that heparinization of chitosan/PLAGA scaffolds did not significantly alter the mechanical properties and porous structures. In addition, the heparinized chitosan/PLAGA scaffolds possessed a compressive modulus of 403.98 +/- 19.53 MPa and a compressive strength of 9.83 +/- 0.94 MPa, which are in the range of human trabecular bone. Furthermore, the heparinized chitosan/PLAGA scaffolds had an interconnected porous structure with a total pore volume of 30.93 +/- 0.90% and a median pore size of 172.33 +/- 5.89 mum. The effect of immobilized heparin on osteoblast-like MC3T3-E1 cell growth was investigated. MC3T3-E1 cells proliferated three dimensionally throughout the porous structure of the scaffolds. Heparinized chitosan/PLAGA scaffolds with low heparin loading (1.7 microg/scaffold) were shown to be capable of stimulating MC3T3-E1 cell proliferation by MTS assay and cell differentiation as evidenced by elevated osteocalcin expression when compared with nonheparinized chitosan/PLAGA scaffold and chitosan/PLAGA scaffold with high heparin loading (14.1 microg/scaffold). This study demonstrated the potential of functionalizing chitosan/PLAGA scaffolds via heparinization with improved cell functions for bone tissue engineering applications.

  3. Design of a new type of coating for the controlled release of heparin

    NARCIS (Netherlands)

    Hinrichs, W.L.J.; Hinrichs, W.L.J.; ten Hoopen, Hermina W.M.; Wissink, M.J.B.; Engbers, G.H.M.; Feijen, Jan

    1997-01-01

    Thrombus formation at the surface of blood contacting devices can be prevented by local release of heparin. Preferably, the release rate should be constant for prolonged periods of time. The minimum heparin release rate to achieve thromboresistance will be different for various applications and

  4. Platelet count recovery and seroreversion in immune HIT despite continuation of heparin: further observations and literature review.

    Science.gov (United States)

    Shih, Andrew W; Sheppard, Jo-Ann I; Warkentin, Theodore E

    2017-10-05

    One of the standard distinctions between type 1 (non-immune) and type 2 (immune-mediated) heparin-induced thrombocytopenia (HIT) is the transience of thrombocytopenia: type 1 HIT is viewed as early-onset and transient thrombocytopenia, with platelet count recovery despite continuing heparin administration. In contrast, type 2 HIT is viewed as later-onset (i. e., 5 days or later) thrombocytopenia in which it is generally believed that platelet count recovery will not occur unless heparin is discontinued. However, older reports of type 2 HIT sometimes did include the unexpected observation that platelet counts could recover despite continued heparin administration, although without information provided regarding changes in HIT antibody levels in association with platelet count recovery. In recent years, some reports of type 2 HIT have confirmed the observation that platelet count recovery can occur despite continuing heparin administration, with serological evidence of waning levels of HIT antibodies ("seroreversion"). We now report two additional patient cases of type 2 HIT with platelet count recovery despite ongoing therapeutic-dose (1 case) or prophylactic-dose (1 case) heparin administration, in which we demonstrate concomitant waning of HIT antibody levels. We further review the literature describing this phenomenon of HIT antibody seroreversion and platelet count recovery despite continuing heparin administration. Our observations add to the concept that HIT represents a remarkably transient immune response, including sometimes even when heparin is continued.

  5. Assessment of Heparin Anticoagulation Measured Using i-STAT and Hemochron Activated Clotting Time.

    Science.gov (United States)

    Maslow, Andrew; Chambers, Alison; Cheves, Tracey; Sweeney, Joseph

    2018-01-31

    Adequate anticoagulation, measured using activated clotting time (ACT), is important during vascular and cardiac surgeries. Unfractionated heparin is the most common anticoagulant used. The purpose of this analysis was to compare the i-STAT ACT (iACT) to the Hemochron ACT (hACT), both of which were then compared to anti-factor Xa (anti-Xa) assay, a representation of heparin level and activity. Prospective study. Tertiary care cardiovascular center. Eleven consecutive elective adult cardiac surgical patients. Prior to cardiopulmonary bypass, ACTs were measured using i-STAT and Hemochron technologies and compared to each other and to anti-Xa assay prior to and during a cumulative administration of heparin. Data were compared using bias analyses. Heparin (300 U/kg) was administered in quarterly doses. Coagulation labs were collected prior to and 3 minutes after each quarterly dose of heparin. The baseline ACTs for i-STAT and Hemochron were 147 and 142 seconds, respectively. A significant association was found between iACT and hACT (p = 0.002). The iACT measurements underestimated hACT at ACT levels >180 seconds or anti-Xa levels >0.75 U/mL. No significant difference was found between ACT data at anti-Xa levels 0.75 U/mL. Copyright © 2018 Elsevier Inc. All rights reserved.

  6. Ultrasensitive colorimetric detection of heparin based on self-assembly of gold nanoparticles on graphene oxide.

    Science.gov (United States)

    Fu, Xiuli; Chen, Lingxin; Li, Jinhua

    2012-08-21

    A novel colorimetric method was developed for ultrasensitive detection of heparin based on self-assembly of gold nanoparticles (AuNPs) onto the surface of graphene oxide (GO). Polycationic protamine was used as a medium for inducing the self-assembly of citrate-capped AuNPs on GO through electrostatic interaction, resulting in a shift in the surface plasmon resonance (SPR) absorption of AuNPs and exhibiting a blue color. Addition of polyanionic heparin disturbed the self-assemble of AuNPs due to its strong affinity to protamine. With the increase of heparin concentration, the amounts of self-assembly AuNPs decreased and the color changed from blue to red in solution. Therefore, a "blue-to-red" colorimetric sensing strategy based on self-assembly of AuNPs could be established for heparin detection. Compared with the commonly reported aggregation-based methods ("red-to-blue"), the color change from blue to red was more eye-sensitive, especially in low concentration of target. Moreover, stronger interaction between protamine and heparin led to distinguish heparin from its analogues as well as various potentially coexistent physiological species. The strategy was simply achieved by the self-assembly nature of AuNPs and the application of two types of polyionic media, showing it to be label-free, simple, rapid and visual. This method could selectively detect heparin with a detection limit of 3.0 ng mL(-1) in standard aqueous solution and good linearity was obtained over the range 0.06-0.36 μg mL(-1) (R = 0.9936). It was successfully applied to determination of heparin in fetal bovine serum samples as low as 1.7 ng mL(-1) with a linear range of 0-0.8 μg mL(-1).

  7. Human IGF-I propeptide A promotes articular chondrocyte biosynthesis and employs glycosylation-dependent heparin binding.

    Science.gov (United States)

    Shi, Shuiliang; Kelly, Brian J; Wang, Congrong; Klingler, Ken; Chan, Albert; Eckert, George J; Trippel, Stephen B

    2018-03-01

    Insulin-like growth factor I (IGF-I) is a key regulator of chondrogenesis, but its therapeutic application to articular cartilage damage is limited by rapid elimination from the repair site. The human IGF-I gene gives rise to three IGF-I propeptides (proIGF-IA, proIGF-IB and proIGF-IC) that are cleaved to create mature IGF-I. In this study, we elucidate the processing of IGF-I precursors by articular chondrocytes, and test the hypotheses that proIGF-I isoforms bind to heparin and regulate articular chondrocyte biosynthesis. Human IGF-I propeptides and mutants were overexpressed in bovine articular chondrocytes. IGF-I products were characterized by ELISA, western blot and FPLC using a heparin column. The biosynthetic activity of IGF-I products on articular chondrocytes was assayed for DNA and glycosaminoglycan that the cells produced. Secreted IGF-I propeptides stimulated articular chondrocyte biosynthetic activity to the same degree as mature IGF-I. Of the three IGF-I propeptides, only one, proIGF-IA, strongly bound to heparin. Interestingly, heparin binding of proIGF-IA depended on N-glycosylation at Asn92 in the EA peptide. To our knowledge, this is the first demonstration that N-glycosylation determines the binding of a heparin-binding protein to heparin. The biosynthetic and heparin binding abilities of proIGF-IA, coupled with its generation of IGF-I, suggest that proIGF-IA may have therapeutic value for articular cartilage repair. These data identify human pro-insulin-like growth factor IA as a bifunctional protein. Its combined ability to bind heparin and augment chondrocyte biosynthesis makes it a promising therapeutic agent for cartilage damage due to trauma and osteoarthritis. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Implementation of on-line data reduction algorithms in the CMS Endcap Preshower Data Concentrator Cards

    CERN Document Server

    Barney, D; Kokkas, P; Manthos, N; Sidiropoulos, G; Reynaud, S; Vichoudis, P

    2007-01-01

    The CMS Endcap Preshower (ES) sub-detector comprises 4288 silicon sensors, each containing 32 strips. The data are transferred from the detector to the counting room via 1208 optical fibres running at 800Mbps. Each fibre carries data from two, three or four sensors. For the readout of the Preshower, a VME-based system, the Endcap Preshower Data Concentrator Card (ES-DCC), is currently under development. The main objective of each readout board is to acquire on-detector data from up to 36 optical links, perform on-line data reduction via zero suppression and pass the concentrated data to the CMS event builder. This document presents the conceptual design of the Reduction Algorithms as well as their implementation in the ES-DCC FPGAs. These algorithms, as implemented in the ES-DCC, result in a data-reduction factor of 20.

  9. Implementation of On-Line Data Reduction Algorithms in the CMS Endcap Preshower Data Concentrator Card

    CERN Document Server

    Barney, David; Kokkas, Panagiotis; Manthos, Nikolaos; Reynaud, Serge; Sidiropoulos, Georgios; Vichoudis, Paschalis

    2006-01-01

    The CMS Endcap Preshower (ES) sub-detector comprises 4288 silicon sensors, each containing 32 strips. The data are transferred from the detector to the counting room via 1208 optical fibres running at 800Mbps. Each fibre carries data from 2, 3 or 4 sensors. For the readout of the Preshower, a VME-based system - the Endcap Preshower Data Concentrator Card (ES-DCC) is currently under development. The main objective of each readout board is to acquire on-detector data from up to 36 optical links, perform on-line data reduction (zero suppression) and pass the concentrated data to the CMS event builder. This document presents the conceptual design of the Reduction Algorithms as well as their implementation into the ES-DCC FPGAs. The algorithms implemented into the ES-DCC resulted in a reduction factor of ~20.

  10. INCORPORATING ENVIRONMENTAL AND ECONOMIC CONSIDERATIONS INTO PROCESS DESIGN: THE WASTE REDUCTION (WAR) ALGORITHM

    Science.gov (United States)

    A general theory known as the WAste Reduction (WASR) algorithm has been developed to describe the flow and the generation of potential environmental impact through a chemical process. This theory integrates environmental impact assessment into chemical process design Potential en...

  11. Antiproliferative heparin (glycosaminoglycans) isolated from giant ...

    African Journals Online (AJOL)

    STORAGESEVER

    2009-05-18

    May 18, 2009 ... source of these sulfated polysaccharides (Nader and. Dietrich, 1989) and it often corresponds up to 90% of the total GAG content of these organisms. Heparin and heap- rin-like substances have a wide range of important biolo- gical activities including inhibition of pulmonary artery smooth muscle cell ...

  12. A Problem-Reduction Evolutionary Algorithm for Solving the Capacitated Vehicle Routing Problem

    Directory of Open Access Journals (Sweden)

    Wanfeng Liu

    2015-01-01

    Full Text Available Assessment of the components of a solution helps provide useful information for an optimization problem. This paper presents a new population-based problem-reduction evolutionary algorithm (PREA based on the solution components assessment. An individual solution is regarded as being constructed by basic elements, and the concept of acceptability is introduced to evaluate them. The PREA consists of a searching phase and an evaluation phase. The acceptability of basic elements is calculated in the evaluation phase and passed to the searching phase. In the searching phase, for each individual solution, the original optimization problem is reduced to a new smaller-size problem. With the evolution of the algorithm, the number of common basic elements in the population increases until all individual solutions are exactly the same which is supposed to be the near-optimal solution of the optimization problem. The new algorithm is applied to a large variety of capacitated vehicle routing problems (CVRP with customers up to nearly 500. Experimental results show that the proposed algorithm has the advantages of fast convergence and robustness in solution quality over the comparative algorithms.

  13. Gold and silver nanoparticles conjugated with heparin derivative possess anti-angiogenesis properties

    Science.gov (United States)

    Kemp, Melissa M.; Kumar, Ashavani; Mousa, Shaymaa; Dyskin, Evgeny; Yalcin, Murat; Ajayan, Pulickel; Linhardt, Robert J.; Mousa, Shaker A.

    2009-11-01

    Silver and gold nanoparticles display unique physical and biological properties that have been extensively studied for biological and medical applications. Typically, gold and silver nanoparticles are prepared by chemical reductants that utilize excess toxic reactants, which need to be removed for biological purposes. We utilized a clean method involving a single synthetic step to prepare metal nanoparticles for evaluating potential effects on angiogenesis modulation. These nanoparticles were prepared by reducing silver nitrate and gold chloride with diaminopyridinyl (DAP)-derivatized heparin (HP) polysaccharides. Both gold and silver nanoparticles reduced with DAPHP exhibited effective inhibition of basic fibroblast growth factor (FGF-2)-induced angiogenesis, with an enhanced anti-angiogenesis efficacy with the conjugation to DAPHP (Pcancer and inflammatory diseases.

  14. Furin proteolytically processes the heparin-binding region of extracellular superoxide dismutase

    DEFF Research Database (Denmark)

    Bowler, Russell P; Nicks, Mike; Olsen, Dorte Aa

    2002-01-01

    Extracellular superoxide dismutase (EC-SOD) is an antioxidant enzyme that attenuates brain and lung injury from oxidative stress. A polybasic region in the carboxyl terminus distinguishes EC-SOD from other superoxide dismutases and determines EC-SOD's tissue half-life and affinity for heparin....... There are two types of EC-SOD that differ based on the presence or absence of this heparin-binding region. It has recently been shown that proteolytic removal of the heparin-binding region is an intracellular event (Enghild, J. J., Thogersen, I. B., Oury, T. D., Valnickova, Z., Hojrup, P., and Crapo, J. D...... of intracellular proteases implicate furin as a processing protease. In vitro experiments using furin and purified EC-SOD suggest that furin proteolytically cleaves EC-SOD in the middle of the polybasic region and then requires an additional carboxypeptidase to remove the remaining lysines and arginines...

  15. Indium-111-labeled platelets: effect of heparin on uptake by venous thrombi and relationship to the activated partial thromboplastin time

    International Nuclear Information System (INIS)

    Fedullo, P.F.; Moser, K.M.; Moser, K.S.; Konopka, R.; Hartman, M.T.

    1982-01-01

    The goal of heparin thepapy in deep vein thrombosis is to prevent thrombus extension. The relationship between thrombus extension and the results of coagulation tests used to monitor heparin thepapy is unclear. To expose this relationship, we studied the effect of several heparin regimens on the accretion of indium-111-labeled platelets on fresh venous thrombi, as detected by gamma imaging, and monitored the activated partial thromboplastin time (APTT). Six dogs were treated with a 300-U/kg bolus of heparin followed by a 90-U/kg/hour heparin infusion, a dose of heparin sufficient to increase the APTT to levels greater than eight times baseline (APTT ratio); platelet accretion (thrombus imaging) occurred only after the heparin effect was reversed with protamine sulfate. Nineteen dogs were treated with a 150-U/kg bolus of heparin followed by a 4-hour, 45-U/kg/hour heparin infusion; a thrombus was demonstrated only after protamine injection in 12 (mean APTT ratio 1.3 +/- 0.19) and before protamine injection in seven. In thirteen of these 19 dogs, 30 minutes separated the platelet injection from heparin therapy, while in six this duration was less than 30 minutes. In four of these six dogs, thrombi were demonstrated before protamine therapy and at APTT ratios greater than 3.0. Finally, 10 dogs were treated with a 100-U/kg bolus followed by a 3-hour, 50-U/kg/hour heparin infusion, after which the APTT was allowed to return to baseline values spontaneously. In all 10 dogs, a thrombus was demonstrated only after cessation of the heparin infusion, and at a mean APTT ratio of 1.4 +/- 0.15 times baseline. These results suggest that, except with very early platelet injection, platelet accretion by thrombi is consistently inhibited by heparin at APTT ratios greater than 2.5

  16. Molecular Weights of Bovine and Porcine Heparin Samples: Comparison of Chromatographic Methods and Results of a Collaborative Survey

    Directory of Open Access Journals (Sweden)

    Sabrina Bertini

    2017-07-01

    Full Text Available In a collaborative study involving six laboratories in the USA, Europe, and India the molecular weight distributions of a panel of heparin sodium samples were determined, in order to compare heparin sodium of bovine intestinal origin with that of bovine lung and porcine intestinal origin. Porcine samples met the current criteria as laid out in the USP Heparin Sodium monograph. Bovine lung heparin samples had consistently lower average molecular weights. Bovine intestinal heparin was variable in molecular weight; some samples fell below the USP limits, some fell within these limits and others fell above the upper limits. These data will inform the establishment of pharmacopeial acceptance criteria for heparin sodium derived from bovine intestinal mucosa. The method for MW determination as described in the USP monograph uses a single, broad standard calibrant to characterize the chromatographic profile of heparin sodium on high-resolution silica-based GPC columns. These columns may be short-lived in some laboratories. Using the panel of samples described above, methods based on the use of robust polymer-based columns have been developed. In addition to the use of the USP’s broad standard calibrant for heparin sodium with these columns, a set of conditions have been devised that allow light-scattering detected molecular weight characterization of heparin sodium, giving results that agree well with the monograph method. These findings may facilitate the validation of variant chromatographic methods with some practical advantages over the USP monograph method.

  17. Molecular Weights of Bovine and Porcine Heparin Samples: Comparison of Chromatographic Methods and Results of a Collaborative Survey.

    Science.gov (United States)

    Bertini, Sabrina; Risi, Giulia; Guerrini, Marco; Carrick, Kevin; Szajek, Anita Y; Mulloy, Barbara

    2017-07-19

    In a collaborative study involving six laboratories in the USA, Europe, and India the molecular weight distributions of a panel of heparin sodium samples were determined, in order to compare heparin sodium of bovine intestinal origin with that of bovine lung and porcine intestinal origin. Porcine samples met the current criteria as laid out in the USP Heparin Sodium monograph. Bovine lung heparin samples had consistently lower average molecular weights. Bovine intestinal heparin was variable in molecular weight; some samples fell below the USP limits, some fell within these limits and others fell above the upper limits. These data will inform the establishment of pharmacopeial acceptance criteria for heparin sodium derived from bovine intestinal mucosa. The method for MW determination as described in the USP monograph uses a single, broad standard calibrant to characterize the chromatographic profile of heparin sodium on high-resolution silica-based GPC columns. These columns may be short-lived in some laboratories. Using the panel of samples described above, methods based on the use of robust polymer-based columns have been developed. In addition to the use of the USP's broad standard calibrant for heparin sodium with these columns, a set of conditions have been devised that allow light-scattering detected molecular weight characterization of heparin sodium, giving results that agree well with the monograph method. These findings may facilitate the validation of variant chromatographic methods with some practical advantages over the USP monograph method.

  18. Iterative metal artefact reduction (MAR) in postsurgical chest CT: comparison of three iMAR-algorithms.

    Science.gov (United States)

    Aissa, Joel; Boos, Johannes; Sawicki, Lino Morris; Heinzler, Niklas; Krzymyk, Karl; Sedlmair, Martin; Kröpil, Patric; Antoch, Gerald; Thomas, Christoph

    2017-11-01

    The purpose of this study was to evaluate the impact of three novel iterative metal artefact (iMAR) algorithms on image quality and artefact degree in chest CT of patients with a variety of thoracic metallic implants. 27 postsurgical patients with thoracic implants who underwent clinical chest CT between March and May 2015 in clinical routine were retrospectively included. Images were retrospectively reconstructed with standard weighted filtered back projection (WFBP) and with three iMAR algorithms (iMAR-Algo1 = Cardiac algorithm, iMAR-Algo2 = Pacemaker algorithm and iMAR-Algo3 = ThoracicCoils algorithm). The subjective and objective image quality was assessed. Averaged over all artefacts, artefact degree was significantly lower for the iMAR-Algo1 (58.9 ± 48.5 HU), iMAR-Algo2 (52.7 ± 46.8 HU) and the iMAR-Algo3 (51.9 ± 46.1 HU) compared with WFBP (91.6 ± 81.6 HU, p algorithms, respectively. iMAR-Algo2 and iMAR-Algo3 reconstructions decreased mild and moderate artefacts compared with WFBP and iMAR-Algo1 (p algorithms led to a significant reduction of metal artefacts and increase in overall image quality compared with WFBP in chest CT of patients with metallic implants in subjective and objective analysis. The iMARAlgo2 and iMARAlgo3 were best for mild artefacts. IMARAlgo1 was superior for severe artefacts. Advances in knowledge: Iterative MAR led to significant artefact reduction and increase image-quality compared with WFBP in CT after implementation of thoracic devices. Adjusting iMAR-algorithms to patients' metallic implants can help to improve image quality in CT.

  19. Study of the Efficacy, Safety and Tolerability of Low-Molecular-Weight Heparin vs. Unfractionated Heparin as Bridging Therapy in Patients with Embolic Stroke due to Atrial Fibrillation.

    Science.gov (United States)

    Feiz, Farnia; Sedghi, Reyhane; Salehi, Alireza; Hatam, Nahid; Bahmei, Jamshid; Borhani-Haghighi, Afshin

    2016-06-01

    Anticoagulation with adjusted dose warfarin is a well-accepted treatment for the prevention of recurrent stroke in patients with atrial fibrillation. Meanwhile, using bridging therapy with heparin or heparinoids before warfarin for initiation of anticoagulation is a matter of debate. We compared safety, efficacy, and tolerability of low-molecular-weight heparin (LMWH) and unfractionated heparin (UFH) as a bridging method in patients with recent ischemic stroke due to atrial fibrillation. This study was a randomized single-blind controlled trial in patients with acute ischemic stroke due to atrial fibrillation who were eligible for receiving warfarin and were randomly treated with 60 milligrams (mg) of LMWH (enoxaparin) subcutaneously every 12 h, or 1000 units/h of continuous intravenous heparin. The primary efficacy endpoints were recurrence of new ischemic stroke, myocardial infarction and/or death. The primary safety endpoint was central nervous system and/or systemic bleeding. Seventy-four subjects were recruited. Baseline demographic and clinical characteristics of two groups were matched. Composite endpoint outcome of new ischemic stroke, myocardial infarction, and/or death in follow-up period was seen in 10 subjects (27.03%) in UFH group and in four subjects (10.81%) in LMWH group (p value: 0.136). All hemorrhages and symptomatic central nervous system (CNS) hemorrhages in follow-up period were in 7 (18.9%) and 4 (10.8%) patients in UFH group, in 5 (13.5%), and 3 (8.1%) patients in LMWH group (p values: 0.754 and 0.751), respectively. Drop out and major adverse-effects such as heparin-induced thrombocytopenia and drug hypersensitivity were not seen in any patient. Enoxaparin can be a safe and efficient alternative for UFH as bridging therapy.

  20. 111In-labeled platelets: effects of heparin on uptake by venous thrombi and relationship to the activated partial thromboplastin time

    International Nuclear Information System (INIS)

    Fedullo, P.F.; Moser, K.M.; Moser, K.S.; Konopka, R.; Hartman, M.T.

    1982-01-01

    The goal of heparin therapy in deep vein thrombosis is to prevent thrombus extension. The relationship between thrombus extension and the results of coagulation tests used to monitor heparin therapy is unclear. To explore this relationship, we studied the effect of several heparin regimens on the accretion of 111 In-labeled platelets on fresh venous thrombi, as detected by gamma imaging, and monitored the activated partial thromboplastin time (APTT). Six dogs were treated with a 300-U/kg bolus of heparin followed by a 90-U/kg/hour heparin infusion, a dose of heparin sufficient to increase the APTT to levels greater than eight times baseline (APTT ratio); platelet accretion (thrombus imaging) occurred only after the heparin effect was reversed with protamine sulfate. Nineteen dogs were treated with a 150-U/kg bolus of heparin followed by a 4-hour, 45-U/kg/hour heparin infusion; a thrombus was demonstrated only after protamine injection in 12 (mean APTT ratio 1.3 +/- 0.19) and before protamine injection in seven. In thirteen of these 19 dogs, 30 minutes separated the platelet injection from heparin therapy, while in six this duration was less than 30 minutes. In four of these six dogs, thrombi were demonstrated before protamine therapy and at APTT ratios greater than 3.0. Finally, 10 dogs were treated with a 100-U/kg bolus followed by a 3-hour, 50-U/kg/hour heparin infusion, after which the APTT was allowed to return to baseline values spontaneously. In all 10 dogs, a thrombus was demonstrated only after cessation of the heparin infusion, and at a mean APTT ratio of 1.4 +/- 0.15 times baseline. These results suggest that, except with very early platelet injection, platelet accretion by thrombi is consistently inhibited by heparin at APTT ratios greater than 2.5. Platelet accretion by venous thrombi occurs within narrow limits of heparin effect as reflected by the APTT

  1. Safety and Efficacy of Argatroban in the Management of Heparin-Induced Thrombocytopenia

    Directory of Open Access Journals (Sweden)

    Bernd Saugel

    2011-01-01

    Full Text Available Heparin-induced thrombocytopenia (HIT is a life-threatening adverse reaction to heparin therapy that is characterized by thrombocytopenia and an increased risk of venous and arterial thrombosis. According to guidelines, in patients with strongly suspected or confirmed HIT all sources of heparin have to be discontinued and an alternative, nonheparin anticoagulant for HIT treatment must immediately be started. For both the prophylaxis of thrombembolic events in HIT and the treatment of HIT with thrombosis the direct thrombin inhibitor argatroban is approved in the United States. The objective of this review is to describe the mechanism of action and the pharmacokinetic profile of argatroban, to characterize argatroban regarding its safety and therapeutic efficacy and to discuss its place in therapy in HIT.

  2. Study on the Noise Reduction of Vehicle Exhaust NOX Spectra Based on Adaptive EEMD Algorithm

    Directory of Open Access Journals (Sweden)

    Kai Zhang

    2017-01-01

    Full Text Available It becomes a key technology to measure the concentration of the vehicle exhaust components with the transmission spectra. But in the conventional methods for noise reduction and baseline correction, such as wavelet transform, derivative, interpolation, polynomial fitting, and so forth, the basic functions of these algorithms, the number of decomposition layers, and the way to reconstruct the signal have to be adjusted according to the characteristics of different components in the transmission spectra. The parameter settings of the algorithms above are not transcendental, so with them, it is difficult to achieve the best noise reduction effect for the vehicle exhaust spectra which are sharp and drastic in the waveform. In this paper, an adaptive ensemble empirical mode decomposition (EEMD denoising model based on a special normalized index optimization is proposed and used in the spectral noise reduction of vehicle exhaust NOX. It is shown with the experimental results that the method can effectively improve the accuracy of the spectral noise reduction and simplify the denoising process and its operation difficulty.

  3. Genetic Algorithm-Based Model Order Reduction of Aeroservoelastic Systems with Consistant States

    Science.gov (United States)

    Zhu, Jin; Wang, Yi; Pant, Kapil; Suh, Peter M.; Brenner, Martin J.

    2017-01-01

    This paper presents a model order reduction framework to construct linear parameter-varying reduced-order models of flexible aircraft for aeroservoelasticity analysis and control synthesis in broad two-dimensional flight parameter space. Genetic algorithms are used to automatically determine physical states for reduction and to generate reduced-order models at grid points within parameter space while minimizing the trial-and-error process. In addition, balanced truncation for unstable systems is used in conjunction with the congruence transformation technique to achieve locally optimal realization and weak fulfillment of state consistency across the entire parameter space. Therefore, aeroservoelasticity reduced-order models at any flight condition can be obtained simply through model interpolation. The methodology is applied to the pitch-plant model of the X-56A Multi-Use Technology Testbed currently being tested at NASA Armstrong Flight Research Center for flutter suppression and gust load alleviation. The present studies indicate that the reduced-order model with more than 12× reduction in the number of states relative to the original model is able to accurately predict system response among all input-output channels. The genetic-algorithm-guided approach exceeds manual and empirical state selection in terms of efficiency and accuracy. The interpolated aeroservoelasticity reduced order models exhibit smooth pole transition and continuously varying gains along a set of prescribed flight conditions, which verifies consistent state representation obtained by congruence transformation. The present model order reduction framework can be used by control engineers for robust aeroservoelasticity controller synthesis and novel vehicle design.

  4. FPGA based algorithms for data reduction at Belle II

    Energy Technology Data Exchange (ETDEWEB)

    Muenchow, David; Gessler, Thomas; Kuehn, Wolfgang; Lange, Jens Soeren; Liu, Ming; Spruck, Bjoern [II. Physikalisches Institut, Universitaet Giessen (Germany)

    2011-07-01

    Belle II, the upgrade of the existing Belle experiment at Super-KEKB in Tsukuba, Japan, is an asymmetric e{sup +}e{sup -} collider with a design luminosity of 8.10{sup 35}cm{sup -2}s{sup -1}. At Belle II the estimated event rate is {<=}30 kHz. The resulting data rate at the Pixel Detector (PXD) will be {<=}7.2 GB/s. This data rate needs to be reduced to be able to process and store the data. A region of interest (ROI) selection is based upon two mechanisms. a.) a tracklet finder using the silicon strip detector and b.) the HLT using all other Belle II subdetectors. These ROIs and the pixel data are forwarded to an FPGA based Compute Node for processing. Here a VHDL based algorithm on FPGA with the benefit of pipelining and parallelisation will be implemented. For a fast data handling we developed a dedicated memory management system for buffering and storing the data. The status of the implementation and performance tests of the memory manager and data reduction algorithm is presented.

  5. Hemocompatible ɛ-polylysine-heparin microparticles: A platform for detecting triglycerides in whole blood.

    Science.gov (United States)

    Xu, Tingting; Chi, Bo; Chu, Meilin; Zhang, Qicheng; Zhan, Shuyue; Shi, Rongjia; Xu, Hong; Mao, Chun

    2018-01-15

    Triglycerides are clinically important marker for atherosclerosis, heart disease and hypertension. Here, a platform for detecting triglycerides in whole blood directly was developed based on hemocompatible ɛ-polylysine-heparin microparticles. The obtained products of ɛ-polylysine-heparin microparticles were characterized by fourier transform infrared (FT-IR) spectra, transmission electron microscopy (TEM) and ζ-potential. Moreover, the blood compatibility of ɛ-polylysine-heparin microparticles was characterized by in vitro coagulation tests, hemolysis assay and whole blood adhesion tests. Considering of uniform particle size, good dispersibility and moderate long-term anticoagulation capability of the microparticles, a Lipase-(ɛ-polylysine-heparin)-glassy carbon electrode (GCE) was constructed to detect triglycerides. The proposed biosensor had good electrocatalytic activity towards triglycerides, in which case the sensitivity was 0.40μAmg -1 dLcm -2 and the detection limit was 4.67mgdL -1 (S/N = 3). Meanwhile, the Lipase-(ɛ-polylysine-heparin)-GCE electrode had strong anti-interference ability as well as a long shelf-life. Moreover, for the detection of triglycerides in whole blood directly, the detection limit was as low as 5.18mgdL -1 . The new constructed platform is suitable for detecting triglycerides in whole blood directly, which provides new analytical systems for clinical illness diagnosis. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Printed microfluidic filter for heparinized blood.

    Science.gov (United States)

    Bilatto, Stanley E R; Adly, Nouran Y; Correa, Daniel S; Wolfrum, Bernhard; Offenhäusser, Andreas; Yakushenko, Alexey

    2017-05-01

    A simple lab-on-a-chip method for blood plasma separation was developed by combining stereolithographic 3D printing with inkjet printing, creating a completely sealed microfluidic device. In some approaches, one dilutes the blood sample before separation, reducing the concentration of a target analyte and increasing a contamination risk. In this work, a single drop (8  μ l) of heparinized whole blood could be efficiently filtered using a capillary effect without any external driving forces and without dilution. The blood storage in heparin tubes during 24 h at 4 °C initiated the formation of small crystals that formed auto-filtration structures in the sample upon entering the 3D-printed device, with pores smaller than the red blood cells, separating plasma from the cellular content. The total filtration process took less than 10 s. The presented printed plasma filtration microfluidics fabricated with a rapid prototyping approach is a miniaturized, fast and easy-to-operate device that can be integrated into healthcare/portable systems for point-of-care diagnostics.

  7. Heparin-independent, PF4-dependent binding of HIT antibodies to platelets: implications for HIT pathogenesis.

    Science.gov (United States)

    Padmanabhan, Anand; Jones, Curtis G; Bougie, Daniel W; Curtis, Brian R; McFarland, Janice G; Wang, Demin; Aster, Richard H

    2015-01-01

    Antibodies specific for platelet factor 4 (PF4)/heparin complexes are the hallmark of heparin-induced thrombocytopenia and thrombosis (HIT), but many antibody-positive patients have normal platelet counts. The basis for this is not fully understood, but it is believed that antibodies testing positive in the serotonin release assay (SRA) are the most likely to cause disease. We addressed this issue by characterizing PF4-dependent binding of HIT antibodies to intact platelets and found that most antibodies testing positive in the SRA, but none of those testing negative, bind to and activate platelets when PF4 is present without any requirement for heparin (P HIT antibodies recognize PF4 in a complex with heparin, only a subset of these antibodies recognize more subtle epitopes induced in PF4 when it binds to CS, the major platelet glycosaminoglycan. Antibodies having this property could explain "delayed HIT" seen in some individuals after discontinuation of heparin and the high risk for thrombosis that persists for weeks in patients recovered from HIT. © 2015 by The American Society of Hematology.

  8. Effect of heparin calcium different concentrations on some physical properties and structure in polyacrylamide matrix

    International Nuclear Information System (INIS)

    Abdelrazek, E.M.; Ibrahim, Hosam S.

    2010-01-01

    Films of polyacrylamide (PAAm) doped with different concentrations of heparin calcium, from 0.0 to 8 wt%, have been prepared by casting method. Studies were carried out utilizing X-ray, FT-IR, UV/VIS, DSC and DC electrical conduction to characterize the structural, optical and thermal properties of the films. Results revealed that the structural and chemical characterizations of PAAm films are affected by the addition of heparin calcium content. XRD spectra revealed that the amorphous phases increase with increase in filling levels of heparin (FLs). FT-IR analysis revealed that incorporation of heparin calcium leads to a small modification in the spectra of films. The optical absorption spectra in the UV/VIS region revealed structural variation increases with increase in concentration, which is reflected in the form of decrease in the energy band gap E g . Significant changes of DSC curves of the films suggest that strong interaction established between heparin calcium and PAAm molecules. The DC electric conduction data were interpreted on the basis of an intrachain one-dimensional interpolaron hopping model of Kuivalainen.

  9. Selective interaction of heparin with the variable region 3 within surface glycoprotein of laboratory-adapted feline immunodeficiency virus.

    Directory of Open Access Journals (Sweden)

    Qiong-Ying Hu

    Full Text Available Heparan sulfate proteoglycans (HSPG can act as binding receptors for certain laboratory-adapted (TCA strains of feline immunodeficiency virus (FIV and human immunodeficiency virus (HIV. Heparin, a soluble heparin sulfate (HS, can inhibit TCA HIV and FIV entry mediated by HSPG interaction in vitro. In the present study, we further determined the selective interaction of heparin with the V3 loop of TCA of FIV. Our current results indicate that heparin selectively inhibits infection by TCA strains, but not for field isolates (FS. Heparin also specifically interferes with TCA surface glycoprotein (SU binding to CXCR4, by interactions with HSPG binding sites on the V3 loop of the FIV envelope protein. Peptides representing either the N- or C-terminal side of the V3 loop and containing HSPG binding sites were able to compete away the heparin block of TCA SU binding to CXCR4. Heparin does not interfere with the interaction of SU with anti-V3 antibodies that target the CXCR4 binding region or with the interaction between FS FIV and anti-V3 antibodies since FS SU has no HSPG binding sites within the HSPG binding region. Our data show that heparin blocks TCA FIV infection or entry not only through its competition of HSPG on the cell surface interaction with SU, but also by its interference with CXCR4 binding to SU. These studies aid in the design and development of heparin derivatives or analogues that can inhibit steps in virus infection and are informative regarding the HSPG/SU interaction.

  10. A new approach for heparin standardization: combination of scanning UV spectroscopy, nuclear magnetic resonance and principal component analysis.

    Directory of Open Access Journals (Sweden)

    Marcelo A Lima

    Full Text Available The year 2007 was marked by widespread adverse clinical responses to heparin use, leading to a global recall of potentially affected heparin batches in 2008. Several analytical methods have since been developed to detect impurities in heparin preparations; however, many are costly and dependent on instrumentation with only limited accessibility. A method based on a simple UV-scanning assay, combined with principal component analysis (PCA, was developed to detect impurities, such as glycosaminoglycans, other complex polysaccharides and aromatic compounds, in heparin preparations. Results were confirmed by NMR spectroscopy. This approach provides an additional, sensitive tool to determine heparin purity and safety, even when NMR spectroscopy failed, requiring only standard laboratory equipment and computing facilities.

  11. Assessment of HIT Antibody Complex in Hip Fracture Patients Receiving Enoxaparin or Unfractionated Heparin

    DEFF Research Database (Denmark)

    Griffin, Justin W; Hopkinson, William J; Rud-Lassen, Michael

    2011-01-01

    of antiheparin-PF4 antibodies and a greater prevalence of immunoglobulin G (IgG) subtype. Heparin and enoxaparin are capable of generating heparin-induced thrombocytopenia (HIT) antibodies in elderly patients undergoing orthopedic surgery but perhaps not to the same extent. When comparing low...

  12. Blooming Artifact Reduction in Coronary Artery Calcification by A New De-blooming Algorithm: Initial Study.

    Science.gov (United States)

    Li, Ping; Xu, Lei; Yang, Lin; Wang, Rui; Hsieh, Jiang; Sun, Zhonghua; Fan, Zhanming; Leipsic, Jonathon A

    2018-05-02

    The aim of this study was to investigate the use of de-blooming algorithm in coronary CT angiography (CCTA) for optimal evaluation of calcified plaques. Calcified plaques were simulated on a coronary vessel phantom and a cardiac motion phantom. Two convolution kernels, standard (STND) and high-definition standard (HD STND), were used for imaging reconstruction. A dedicated de-blooming algorithm was used for imaging processing. We found a smaller bias towards measurement of stenosis using the de-blooming algorithm (STND: bias 24.6% vs 15.0%, range 10.2% to 39.0% vs 4.0% to 25.9%; HD STND: bias 17.9% vs 11.0%, range 8.9% to 30.6% vs 0.5% to 21.5%). With use of de-blooming algorithm, specificity for diagnosing significant stenosis increased from 45.8% to 75.0% (STND), from 62.5% to 83.3% (HD STND); while positive predictive value (PPV) increased from 69.8% to 83.3% (STND), from 76.9% to 88.2% (HD STND). In the patient group, reduction in calcification volume was 48.1 ± 10.3%, reduction in coronary diameter stenosis over calcified plaque was 52.4 ± 24.2%. Our results suggest that the novel de-blooming algorithm could effectively decrease the blooming artifacts caused by coronary calcified plaques, and consequently improve diagnostic accuracy of CCTA in assessing coronary stenosis.

  13. Heparin-Functionalized chitosan/ κ-carrageenan complexes as potential scaffolds for tissue engineering

    International Nuclear Information System (INIS)

    Dofeliz, Joni L.; Rojas, Nina Rosario L.

    2015-01-01

    Cell-based approaches to tissue regeneration are playing an increasingly important role in bone and cartilage repair. This is made possible through the use of growth factors, which are signaling molecules that induce a number of effects such as cell proliferation, migration and differentiation. But problems arise as these growth factors tend to be expensive, short-lived and slow moving through the extracellular matrix, making them very inefficient in their current form of introduction. One such growth factor is basic fibroblast growth factor (bFGF). The general objective of this study is to construct heparin-functionalized chitosan/κ-carrageenan scaffolds, which when bound to basic fibroblast growth factor (bFGF), may be used in the culture of mesenchymal stem cells for differentiation into cartilage. In this study, gels of semi-interpenetrating networks (semi-IPN) of chitosan and κ-carrageenan (2:4:1 blend ration) were prepared using calcium chloride as a cross-linker. The gels were then functionalized with heparin, which is known for its growth factor binding ability, using 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide (EDC) as cross-linker. The functionalized gels were then reshaped into scaffold on the wells of 48-well plates through freeze-dry method. The scaffolds were found to be realatively porous with pore sizes larger than 100 μm which satisfies the requirements for cell culture. Subsequent thermogravimetric analysis shows that the scaffolds were relatively stable with a degradation temperature of 277°C. Additionally, there was no observable separation of the individual degradation temperatures of chitosan and κ-carrageenan, confirming that a single miscible phase in the form of a semi-IPN structure was created. Results of scanning electron microscopy also showed that the scaffolds were stable under 2 hours of UV sterilization. The FTIR spectra of the heparinized PEC showed characteristic absorption bands (S=O asymetric stretch) in the area of 1160

  14. TPSLVM: a dimensionality reduction algorithm based on thin plate splines.

    Science.gov (United States)

    Jiang, Xinwei; Gao, Junbin; Wang, Tianjiang; Shi, Daming

    2014-10-01

    Dimensionality reduction (DR) has been considered as one of the most significant tools for data analysis. One type of DR algorithms is based on latent variable models (LVM). LVM-based models can handle the preimage problem easily. In this paper we propose a new LVM-based DR model, named thin plate spline latent variable model (TPSLVM). Compared to the well-known Gaussian process latent variable model (GPLVM), our proposed TPSLVM is more powerful especially when the dimensionality of the latent space is low. Also, TPSLVM is robust to shift and rotation. This paper investigates two extensions of TPSLVM, i.e., the back-constrained TPSLVM (BC-TPSLVM) and TPSLVM with dynamics (TPSLVM-DM) as well as their combination BC-TPSLVM-DM. Experimental results show that TPSLVM and its extensions provide better data visualization and more efficient dimensionality reduction compared to PCA, GPLVM, ISOMAP, etc.

  15. Heparin defends against the toxicity of circulating histones in sepsis.

    Science.gov (United States)

    Wang, Feifei; Zhang, Naipu; Li, Biru; Liu, Lanbo; Ding, Lei; Wang, Ying; Zhu, Yimin; Mo, Xi; Cao, Qing

    2015-06-01

    Although circulating histones were demonstrated as major mediators of death in septic mice models, their roles in septic patients are not clarified. The present study sought to evaluate the clinical relevance of the circulating histone levels in septic children, and the antagonizing effects of heparin on circulating histones. Histone levels in the plasma of septic children were significantly higher than healthy controls, and positively correlated with disease severity. Histone treatment could activate NF-κB pathway of the endothelial cells and induce the secretion of large amount of cytokines that further amplify inflammation, subsequently leading to organ damage. Co-injection of low dose heparin with lethal dose histones could protect mouse from organ damage and death by antagonizing circulating histones, and similar effects were also observed in other septic models. Collectively, these findings indicated that circulating histones might serve as key factors in the pathogenesis of sepsis and their levels in plasma might be a marker for disease progression and prognosis. Furthermore, low dose heparin might be an effective therapy to hamper sepsis progression and reduce the mortality.

  16. Bleeding risk during treatment of acute thrombotic events with subcutaneous LMWH compared to intravenous unfractionated heparin; a systematic review.

    Directory of Open Access Journals (Sweden)

    Giorgio Costantino

    Full Text Available BACKGROUND: Low Molecular Weight Heparins (LMWH are at least as effective antithrombotic drugs as Unfractionated Heparin (UFH. However, it is still unclear whether the safety profiles of LMWH and UFH differ. We performed a systematic review to compare the bleeding risk of fixed dose subcutaneous LMWH and adjusted dose UFH for treatment of venous thromboembolism (VTE or acute coronary syndromes (ACS. Major bleeding was the primary end point. METHODS: Electronic databases (MEDLINE, EMBASE, and the Cochrane Library were searched up to May 2010 with no language restrictions. Randomized controlled trials in which subcutaneous LMWH were compared to intravenous UFH for the treatment of acute thrombotic events were selected. Two reviewers independently screened studies and extracted data on study design, study quality, incidence of major bleeding, patients' characteristics, type, dose and number of daily administrations of LMWH, co-treatments, study end points and efficacy outcome. Pooled odds ratios (OR and 95% confidence intervals (CI were calculated using the random effects model. RESULTS: Twenty-seven studies were included. A total of 14,002 patients received UFH and 14,635 patients LMWH. Overall, no difference in major bleeding was observed between LMWH patients and UFH (OR = 0.79, 95% CI 0.60-1.04. In patients with VTE LMWH appeared safer than UFH, (OR = 0.68, 95% CI 0.47-1.00. CONCLUSION: The results of our systematic review suggest that the use of LMWH in the treatment of VTE might be associated with a reduction in major bleeding compared with UFH. The choice of which heparin to use to minimize bleeding risk must be based on the single patient, taking into account the bleeding profile of different heparins in different settings.

  17. Spectral CT metal artifact reduction with an optimization-based reconstruction algorithm

    Science.gov (United States)

    Gilat Schmidt, Taly; Barber, Rina F.; Sidky, Emil Y.

    2017-03-01

    Metal objects cause artifacts in computed tomography (CT) images. This work investigated the feasibility of a spectral CT method to reduce metal artifacts. Spectral CT acquisition combined with optimization-based reconstruction is proposed to reduce artifacts by modeling the physical effects that cause metal artifacts and by providing the flexibility to selectively remove corrupted spectral measurements in the spectral-sinogram space. The proposed Constrained `One-Step' Spectral CT Image Reconstruction (cOSSCIR) algorithm directly estimates the basis material maps while enforcing convex constraints. The incorporation of constraints on the reconstructed basis material maps is expected to mitigate undersampling effects that occur when corrupted data is excluded from reconstruction. The feasibility of the cOSSCIR algorithm to reduce metal artifacts was investigated through simulations of a pelvis phantom. The cOSSCIR algorithm was investigated with and without the use of a third basis material representing metal. The effects of excluding data corrupted by metal were also investigated. The results demonstrated that the proposed cOSSCIR algorithm reduced metal artifacts and improved CT number accuracy. For example, CT number error in a bright shading artifact region was reduced from 403 HU in the reference filtered backprojection reconstruction to 33 HU using the proposed algorithm in simulation. In the dark shading regions, the error was reduced from 1141 HU to 25 HU. Of the investigated approaches, decomposing the data into three basis material maps and excluding the corrupted data demonstrated the greatest reduction in metal artifacts.

  18. The effect of heparin administration on the FT4-levels and on an unspecific peripheral thyroid parameter

    International Nuclear Information System (INIS)

    Eber, B.; Borkenstein, J.; Leb, G.

    1984-01-01

    Heparin produces changes in FT 4 -levels both in vivo and in vitro as determined by commercial kits. Methods utilising the principle of equilibrium dialysis show significant increases whereas methods using T 4 -tracer analogue techniques reveal marked decreases in FT 4 -values. Possible clinical side-effects of heparin administration such as heparin-induced hyperthyroidism and tachyarrhythmias are discussed. The present results confirm the FT 4 -decreasing effect of in vivo and in vitro administration of heparin with FT 4 -RIAs based on the tracer analogue technique; however, the unspecific peripheral thyroid parameter of systolic time-intervals did not reveal any tendency towards hyperthyroidism. Also the discrepant results dependent on the method used, indicate that, following heparin administration FT 4 -levels do not reflect that hormone concentration is relevant to the metabolism of the whole body. (orig.) [de

  19. Prototype metal artefact reduction algorithm in flat panel computed tomography - evaluation in patients undergoing transarterial hepatic radioembolisation.

    Science.gov (United States)

    Hamie, Qeumars Mustafa; Kobe, Adrian Raoul; Mietzsch, Leif; Manhart, Michael; Puippe, Gilbert Dominique; Pfammatter, Thomas; Guggenberger, Roman

    2018-01-01

    To investigate the effect of an on-site prototype metal artefact reduction (MAR) algorithm in cone-beam CT-catheter-arteriography (CBCT-CA) in patients undergoing transarterial radioembolisation (RE) of hepatic masses. Ethical board approved retrospective study of 29 patients (mean 63.7±13.7 years, 11 female), including 16 patients with arterial metallic coils, undergoing CBCT-CA (8s scan, 200 degrees rotation, 397 projections). Image reconstructions with and without prototype MAR algorithm were evaluated quantitatively (streak-artefact attenuation changes) and qualitatively (visibility of hepatic parenchyma and vessels) in near- (3cm) of artefact sources (metallic coils and catheters). Quantitative and qualitative measurements of uncorrected and MAR corrected images and different artefact sources were compared RESULTS: Quantitative evaluation showed significant reduction of near- and far-field streak-artefacts with MAR for both artefact sources (p0.05). Inhomogeneities of attenuation values were significantly higher for metallic coils compared to catheters (pprototype MAR algorithm improves image quality in proximity of metallic coil and catheter artefacts. • Metal objects cause artefacts in cone-beam computed tomography (CBCT) imaging. • These artefacts can be corrected by metal artefact reduction (MAR) algorithms. • Corrected images show significantly better visibility of nearby hepatic vessels and tissue. • Better visibility may facilitate image interpretation, save time and radiation exposure.

  20. Anticoagulant effects of inhaled unfractionated heparin in the dog as determined by partial thromboplastin time and factor Xa activity.

    Science.gov (United States)

    Manion, Jill S; Thomason, John M; Langston, Vernon C; Claude, Andrew K; Brooks, Marjory B; Mackin, Andrew J; Lunsford, Kari V

    2016-01-01

    To evaluate the anticoagulant effects of inhaled heparin in dogs. This study was conducted in 3 phases. In phase 1, bronchoalveolar lavage fluid (BALf) was collected to generate an in vitro calibration curve to relate heparin concentration to the activated partial thromboplastin time (aPTT). In phase 2, heparin was administered via nebulization to determine the threshold dose needed to prolong systemic aPTT. In phase 3, the local anticoagulant activity of inhaled heparin was determined by measurement of BALf anti-Xa activity and aPTT. University teaching hospital. Six healthy intact female Walker Hounds were used in this study. Two dogs were used for each phase. Inhaled unfractionated sodium heparin was administered in doses ranging from 50,000 to 200,000 IU. In vitro addition of heparin to BALf caused a prolongation in aPTT. Inhaled heparin at doses as high as 200,000 IU failed to prolong systemic aPTT, and a threshold dose could not be determined. No significant local anticoagulant effects were detected. Even at doses higher than those known to be effective in people, inhaled heparin appears to have no detectable local or systemic anticoagulant effects in dogs with the current delivery method. © Veterinary Emergency and Critical Care Society 2015.

  1. Heparin-binding peptide amphiphile supramolecular architectures as platforms for angiogenesis and drug delivery

    Science.gov (United States)

    Chow, Lesleyann W.

    A fascinating phenomenon in nature is the self-assembly of molecules into a functional, hierarchical structure. In the past decade, the Stupp Laboratory has developed several classes of self-assembling biomaterials, one of which is the synthetic peptide amphiphile (PA). Self-assembling PAs are attractive and versatile biomolecules that can be customized for specific applications in regenerative medicine. In particular, a heparin-binding peptide amphiphile (HBPA) containing a specific heparin-binding peptide sequence was used here to induce angiogenesis and serve as a delivery vehicle for growth factors and small hydrophobic molecules. Throughout this dissertation, the HBPA/heparin system is used in different architectures for a variety of regenerative medicine applications. In one aspect of this work, hybrid scaffolds made from HBPA/heparin gelled on a poly(L-lactic acid) (PLLA) fiber mesh were used to promote angiogenesis to facilitate pancreatic islet transplantation for the treatment of type 1 diabetes. Delivery of growth factors with HBPA/PLLA scafflolds increased vessel density in vivo and correlated with improved transplant outcomes in a streptozotocin-induced diabetic mouse model. Soluble HBPA nanofiber architectures were also useful for islet transplantation applications. These nanofibers were used at concentrations below gelation to deliver growth factors into the dense islet cell aggregate, promoting cell survival and angiogenesis in vitro. The nanostructures infiltrated the islets and promoted the retention of heparin and growth factors within the islet. Another interesting growth factor release system discussed here is the HBPA membrane structure. HBPA was found to self-assemble with hyaluronic acid, a large biopolymer found in the body, into macroscopic, hierarchically-ordered membranes. Heparin was incorporated into these membranes and affected the membrane's mechanical properties and growth factor release. Human mesenchymal stem cells were also shown

  2. Heparin for prolonging peripheral intravenous catheter use in neonates: a randomized controlled trial.

    Science.gov (United States)

    Upadhyay, A; Verma, K K; Lal, P; Chawla, D; Sreenivas, V

    2015-04-01

    To determine the efficacy of heparinized saline administered as intermittent flush on functional duration of the peripheral intravenous catheter (PIVC) in neonates. Randomized, double-blind and placebo-controlled trial. Neonatal intensive care unit of a teaching hospital. Term and preterm neonates born at >32 weeks of gestation who required PIVC only for intermittent administration of antibiotics. Eligible neonates were randomized to receive 1 ml of either heparinized saline (10 U ml(-1)) (n=60) or normal saline (n=60) every 12 h before and after intravenous antibiotics. Functional duration of first peripheral intravenous catheter. A total of 120 neonates were randomized to two groups of 60 neonates each. The mean (s.d.) of age of babies in case and control group was 5.7 (2.5) days and 4.6 (3.1) days, respectively. The average weight of babies in both the groups was 2.1 kg. Mean functional duration of first catheter was more in heparinized saline group, mean (s.d.) of 71.68 h  (27.3) as compared with 57.7 h (23.6) in normal saline group (P<0.005). The mean (95% confidence interval) difference in functional duration in the two groups was 13.9 h (4.7-23.15). Mean duration of patency for any catheter was also significantly more in heparinized saline group than control group. Heparinized saline flush increases the functional duration of peripheral intravenous catheter.

  3. Prevention of after-cataract by application of heparin treatment of capsular tension ring in Marfan syndrome and subluxation of lens

    Directory of Open Access Journals (Sweden)

    Zhong-Qing Li

    2013-08-01

    Full Text Available AIM: To investigate the effect of heparin treatment on capsular tension ring(CTRin the prevention of after-cataract postoperative patients with Marfan syndrome and subluxation of lens.METHODS: Totally 34 cases(56 eyeswere divided randomly into experimental and control groups. Preoperative heparin 12500 units was added to 500mL Ringer's infusion, and CTR was dealt with heparin stock solution soak for 20 minutes in experimental group; there was no any drugs in the control group's solution, and CTR was not dealt with heparin. Postoperative IOP, anterior chamber reaction, corneal edema, IOL position, posterior capsular opacification were observed.RESULTS: There was statistically significant difference in the posterior capsular opacification between the heparin group(13.3%and the contral group no-heparin(69.2%(PCONCLUSION: The present results indicate that there is the preventive effect on posterior capsular opacification by CTR soaked in heparin in postoperative patients with Marfan syndrome and subluxation of lens, thus contributing to the recovery of visual function.

  4. Vascular access site complication in transfemoral coronary angiography between uninterrupted warfarin and heparin bridging.

    Science.gov (United States)

    Wongcharoen, Wanwarang; Pinyosamosorn, Kittipong; Gunaparn, Siriluck; Boonnayhun, Suchada; Thonghong, Tasalak; Suwannasom, Pannipa; Phrommintikul, Arintaya

    2017-08-01

    Warfarin discontinuation with heparin bridging is a common practice in patients receiving warfarin prior to elective coronary angiography (CAG). The uninterrupted warfarin strategy has been suggested to be alternative option for patients with high thromboembolic risk. Therefore, we aimed to assess the safety of elective transfemoral CAG during uninterrupted warfarin therapy compared to heparin bridging. This study was a randomized open-label design with blinded event evaluation. The 110 consecutive patients (age ≥ 18 years) receiving warfarin before the planned transfemoral CAG were randomly assigned to either heparin bridging or uninterrupted warfarin with targeted INR (2.0-3.0). The primary outcome was the incidence of major vascular access site complications. The baseline characteristics were comparable between two groups (mean age was 60.1 ± 7.8 years, 49 males). The mean INR on the day of CAG of heparin bridging and uninterrupted warfarin groups was 1.2 ± 0.3 and 2.2 ± 0.5 (P warfarin patients (P = 0.243). The total vascular access site complications occurred in 6 (10.9%) heparin-bridging and one (1.8%) uninterrupted warfarin patients (P = 0.113). No patient developed either other bleeding or thromboembolic events during 7 days after CAG. We demonstrated that an uninterrupted warfarin strategy did not increase vascular access site complications in patients undergoing transfemoral CAG compared to heparin bridging therapy. Due to the safety and the ease of uninterrupted warfarin strategy, this approach should be encouraged in patients receiving long-term warfarin who undergo elective transfemoral CAG. © 2017, Wiley Periodicals, Inc.

  5. 21 CFR 864.5680 - Automated heparin analyzer.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Automated heparin analyzer. 864.5680 Section 864.5680 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Automated and Semi-Automated Hematology Devices § 864...

  6. Analysis of the complex formation of heparin with protamine by light scattering and analytical ultracentrifugation: implications for blood coagulation management.

    Science.gov (United States)

    Maurer, Jürgen; Haselbach, Stephanie; Klein, Oliver; Baykut, Doan; Vogel, Vitali; Mäntele, Werner

    2011-02-02

    Heparin, a linear glycosaminoglycan, is used in different forms in anticoagulation treatment. Protamine, a highly positive charged peptide containing about 32 amino acids, acts as an antagonist for heparin to restore normal blood coagulation. The complex formation of protamine with heparin was analyzed by a combination of analytical ultracentrifugation and light scattering. Titration of heparin with protamine in blood plasma preparations results in a drastic increase of turbidity, indicating the formation of nanoscale particles. A similar increase of turbidity was observed in physiological saline solution with or without human serum albumin (HSA). Particle size analysis by analytical ultracentrifugation revealed a particle radius of approximately 30 nm for unfractionated heparin and of approximately 60 nm for low molecular weight heparin upon complexation with excess protamine, in agreement with atomic force microscopy data. In the absence of HSA, larger and more heterogeneous particles were observed. The particles obtained were found to be stable for hours. The particle formation kinetics was analyzed by light scattering at different scattering angles and was found to be complete within several minutes. The time course of particle formation suggests a condensation reaction, with sigmoidal traces for low heparin concentrations and quasi-first-order reaction for high heparin concentrations. Under all conditions, the final scattering intensity reached after several minutes was found to be proportional to the amount of heparin in the blood plasma or buffer solution, provided that excess protamine was available and no multiple scattering occurred. On the basis of a direct relation between particle concentration and the heparin concentration present before protaminization, a light scattering assay was developed which permits the quantitative analysis of the heparin concentration in blood plasma and which could complement or even replace the activated clotting time test

  7. Biosynthesis of heparin. Effects of n-butyrate on cultured mast cells

    International Nuclear Information System (INIS)

    Jacobsson, K.G.; Riesenfeld, J.; Lindahl, U.

    1985-01-01

    Murine mastocytoma cells were incubated in vitro with inorganic [ 35 S]sulfate, in the absence or presence of 2.5 mM n-butyrate, and labeled heparin was isolated. The polysaccharide produced in the presence of butyrate showed a lower charge density on anion exchange chromatography than did the control material and a 3-fold increased proportion of components with high affinity for antithrombin. Structural analysis of heparin labeled with [ 3 H] glucosamine in the presence of butyrate showed that approximately 35% of the glucosamine units were N-acetylated, as compared to approximately 10% in the control material; the nonacetylated glucosamine residues were N-sulfated. The presence of butyrate thus leads to an inhibition of the N-deacetylation/N-sulfation process in heparin biosynthesis, along with an augmented formation of molecules with high affinity for antithrombin. Preincubation of the mastocytoma cells with butyrate was required for manifestation of either effect; when the preincubation period was reduced from 24 to 10 h the effects of butyrate were no longer observed. A polysaccharide formed on incubating mastocytoma microsomal fraction with UDP-[ 3 H]glucuronic acid, UDP-N-acetylglucosamine, and 3'-phosphoadenylylsulfate in the presence of 5 mM butyrate showed the same N-acetyl/N-sulfate ratio as did the corresponding control polysaccharide, produced in the absence of butyrate. These findings suggest that the effect of butyrate on heparin biosynthesis depends on the integrity of the cell

  8. Association between Activated Partial Thromboplastin Time and the Amount of Infused Heparin at Bone Marrow Transplantation.

    Science.gov (United States)

    Kusuda, Machiko; Kimura, Shun-Ichi; Misaki, Yukiko; Yoshimura, Kazuki; Gomyo, Ayumi; Hayakawa, Jin; Tamaki, Masaharu; Akahoshi, Yu; Ugai, Tomotaka; Kameda, Kazuaki; Wada, Hidenori; Ishihara, Yuko; Kawamura, Koji; Sakamoto, Kana; Sato, Miki; Terasako-Saito, Kiriko; Kikuchi, Misato; Nakasone, Hideki; Kako, Shinichi; Tanihara, Aki; Kanda, Yoshinobu

    2018-03-27

    The actual heparin concentration of harvested allogeneic bone marrow varies among harvest centers. We monitor the activated partial thromboplastin time (APTT) of the patient during bone marrow infusion and administer prophylactic protamine according to the APTT. We retrospectively reviewed the charts of consecutive patients who underwent bone marrow transplantation without bone marrow processing at our center between April 2007 and March 2016 (n = 94). APTT was monitored during marrow transfusion in 52 patients. We analyzed the relationship between the APTT ratio and several parameters related to heparin administration. As a result, the weight-based heparin administration rate (U/kg/hour) seemed to be more closely related to the APTT ratio (r = .38, P = .005) than to the total amount of heparin. There was no significant correlation between the APTT ratio and renal or liver function. Bleeding complications during and early after infusion were seen in 3 of 52 patients, and included intracranial, nasal, and punctured-skin bleeding. The APTT ratio during transfusion was over 5.88 in the former 2 patients and 2.14 in the latter. All of these patients recovered without sequelae. In conclusion, slow bone marrow infusion is recommended to decrease the weight-based heparin administration rate when the heparin concentration per patient body weight is high. Copyright © 2018 The American Society for Blood and Marrow Transplantation. Published by Elsevier Inc. All rights reserved.

  9. Optimal design of minimum mean-square error noise reduction algorithms using the simulated annealing technique.

    Science.gov (United States)

    Bai, Mingsian R; Hsieh, Ping-Ju; Hur, Kur-Nan

    2009-02-01

    The performance of the minimum mean-square error noise reduction (MMSE-NR) algorithm in conjunction with time-recursive averaging (TRA) for noise estimation is found to be very sensitive to the choice of two recursion parameters. To address this problem in a more systematic manner, this paper proposes an optimization method to efficiently search the optimal parameters of the MMSE-TRA-NR algorithms. The objective function is based on a regression model, whereas the optimization process is carried out with the simulated annealing algorithm that is well suited for problems with many local optima. Another NR algorithm proposed in the paper employs linear prediction coding as a preprocessor for extracting the correlated portion of human speech. Objective and subjective tests were undertaken to compare the optimized MMSE-TRA-NR algorithm with several conventional NR algorithms. The results of subjective tests were processed by using analysis of variance to justify the statistic significance. A post hoc test, Tukey's Honestly Significant Difference, was conducted to further assess the pairwise difference between the NR algorithms.

  10. Taurolidine lock is superior to heparin lock in the prevention of catheter related bloodstream infections and occlusions.

    Directory of Open Access Journals (Sweden)

    Evelyn D Olthof

    Full Text Available Patients on home parenteral nutrition (HPN are at risk for catheter-related complications; mainly infections and occlusions. We have previously shown in HPN patients presenting with catheter sepsis that catheter locking with taurolidine dramatically reduced re-infections when compared with heparin. Our HPN population therefore switched from heparin to taurolidine in 2008. The aim of the present study was to compare long-term effects of this catheter lock strategy on the occurrence of catheter-related bloodstream infections and occlusions in HPN patients.Data of catheter-related complications were retrospectively collected from 212 patients who received HPN between January 2000 and November 2011, comprising 545 and 200 catheters during catheter lock therapy with heparin and taurolidine, respectively. We evaluated catheter-related bloodstream infection and occlusion incidence rates using Poisson-normal regression analysis. Incidence rate ratios were calculated by dividing incidence rates of heparin by those of taurolidine, adjusting for underlying disease, use of anticoagulants or immune suppressives, frequency of HPN/fluid administration, composition of infusion fluids, and duration of HPN/fluid use before catheter creation.Bloodstream infection incidence rates were 1.1/year for heparin and 0.2/year for taurolidine locked catheters. Occlusion incidence rates were 0.2/year for heparin and 0.1/year for taurolidine locked catheters. Adjusted incidence ratios of heparin compared to taurolidine were 5.9 (95% confidence interval, 3.9-8.7 for bloodstream infections and 1.9 (95% confidence interval, 1.1-3.1 for occlusions.Given that no other procedural changes than the catheter lock strategy were implemented during the observation period, these data strongly suggest that taurolidine decreases catheter-related bloodstream infections and occlusions in HPN patients compared with heparin.

  11. Heparin modulates the endopeptidase activity of Leishmania mexicana cysteine protease cathepsin L-Like rCPB2.8.

    Directory of Open Access Journals (Sweden)

    Wagner A S Judice

    Full Text Available Cysteine protease B is considered crucial for the survival and infectivity of the Leishmania in its human host. Several microorganism pathogens bind to the heparin-like glycosaminoglycans chains of proteoglycans at host-cell surface to promote their attachment and internalization. Here, we have investigated the influence of heparin upon Leishmania mexicana cysteine protease rCPB2.8 activity.THE DATA ANALYSIS REVEALED THAT THE PRESENCE OF HEPARIN AFFECTS ALL STEPS OF THE ENZYME REACTION: (i it decreases 3.5-fold the k 1 and 4.0-fold the k -1, (ii it affects the acyl-enzyme accumulation with pronounced decrease in k 2 (2.7-fold, and also decrease in k 3 (3.5-fold. The large values of ΔG  =  12 kJ/mol for the association and dissociation steps indicate substantial structural strains linked to the formation/dissociation of the ES complex in the presence of heparin, which underscore a conformational change that prevents the diffusion of substrate in the rCPB2.8 active site. Binding to heparin also significantly decreases the α-helix content of the rCPB2.8 and perturbs the intrinsic fluorescence emission of the enzyme. The data strongly suggest that heparin is altering the ionization of catalytic (Cys(25-S(-/(His(163-Im(+ H ion pair of the rCPB2.8. Moreover, the interaction of heparin with the N-terminal pro-region of rCPB2.8 significantly decreased its inhibitory activity against the mature enzyme.Taken together, depending on their concentration, heparin-like glycosaminoglycans can either stimulate or antagonize the activity of cysteine protease B enzymes during parasite infection, suggesting that this glycoconjugate can anchor parasite cysteine protease at host cell surface.

  12. Convective Leakage Makes Heparin Locking of Central Venous Catheters Ineffective Within Seconds: Experimental Measurements in a Model Superior Vena Cava.

    Science.gov (United States)

    Barbour, Michael C; McGah, Patrick M; Ng, Chin H; Clark, Alicia M; Gow, Kenneth W; Aliseda, Alberto

    2015-01-01

    Central venous catheters (CVCs), placed in the superior vena cava (SVC) for hemodialysis or chemotherapy, are routinely filled while not in use with heparin, an anticoagulant, to maintain patency and prevent thrombus formation at the catheter tip. The heparin-locking procedure, however, places the patient at risk for systemic bleeding, as heparin is known to leak from the catheter into the blood stream. We provide evidence from detailed in vitro experiments that shows the driving mechanism behind heparin leakage to be convective-diffusive transport due to the pulsatile flow surrounding the catheter. This novel mechanism is supported by experimental planar laser-induced fluorescence (PLIF) and particle image velocimetry (PIV) measurements of flow velocity and heparin transport from a CVC placed inside a model SVC inside a pulsatile flow loop. The results predict an initial, fast (<10 s), convection-dominated phase that rapidly depletes the concentration of heparin in the near-tip region, the region of the catheter with side holes. This is followed by a slow, diffusion-limited phase inside the catheter lumen, where the concentration is still high, that is insufficient at replenishing the lost heparin concentration in the near-tip region. The results presented here, which are consistent with previous in vivo estimates of 24 hour leakage rates, predict that the concentration of heparin in the near-tip region is essentially zero for the majority of the interdialytic phase, rendering the heparin locking procedure ineffective.

  13. Metal artifact reduction algorithm based on model images and spatial information

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Jay [Institute of Radiological Science, Central Taiwan University of Science and Technology, Taichung, Taiwan (China); Shih, Cheng-Ting [Department of Biomedical Engineering and Environmental Sciences, National Tsing-Hua University, Hsinchu, Taiwan (China); Chang, Shu-Jun [Health Physics Division, Institute of Nuclear Energy Research, Taoyuan, Taiwan (China); Huang, Tzung-Chi [Department of Biomedical Imaging and Radiological Science, China Medical University, Taichung, Taiwan (China); Sun, Jing-Yi [Institute of Radiological Science, Central Taiwan University of Science and Technology, Taichung, Taiwan (China); Wu, Tung-Hsin, E-mail: tung@ym.edu.tw [Department of Biomedical Imaging and Radiological Sciences, National Yang-Ming University, No.155, Sec. 2, Linong Street, Taipei 112, Taiwan (China)

    2011-10-01

    Computed tomography (CT) has become one of the most favorable choices for diagnosis of trauma. However, high-density metal implants can induce metal artifacts in CT images, compromising image quality. In this study, we proposed a model-based metal artifact reduction (MAR) algorithm. First, we built a model image using the k-means clustering technique with spatial information and calculated the difference between the original image and the model image. Then, the projection data of these two images were combined using an exponential weighting function. At last, the corrected image was reconstructed using the filter back-projection algorithm. Two metal-artifact contaminated images were studied. For the cylindrical water phantom image, the metal artifact was effectively removed. The mean CT number of water was improved from -28.95{+-}97.97 to -4.76{+-}4.28. For the clinical pelvic CT image, the dark band and the metal line were removed, and the continuity and uniformity of the soft tissue were recovered as well. These results indicate that the proposed MAR algorithm is useful for reducing metal artifact and could improve the diagnostic value of metal-artifact contaminated CT images.

  14. Implementation of the U.S. Environmental Protection Agency's Waste Reduction (WAR) Algorithm in Cape-Open Based Process Simulators

    Science.gov (United States)

    The Sustainable Technology Division has recently completed an implementation of the U.S. EPA's Waste Reduction (WAR) Algorithm that can be directly accessed from a Cape-Open compliant process modeling environment. The WAR Algorithm add-in can be used in AmsterChem's COFE (Cape-Op...

  15. Clinical effects of low-molecular-weight heparin combined with ...

    African Journals Online (AJOL)

    Tropical Journal of Pharmaceutical Research August 2016; 15 (8): 1787-1792 ... Keywords: Acute pancreatitis, Low-molecular-weight heparin, Multiple organ function syndrome,. APACHE II score ... mediators by lowering the expression of.

  16. [Morphology research of the rat sciatic nerve bridged by collage-heparin sulfate scaffold].

    Science.gov (United States)

    Wang, Shu-sen; Hu, Yun-yu; Luo, Zhuo-jing; Chen, Liang-wei; Liu, Hui-ling; Meng, Guo-lin; Lü, Rong; Xu, Xin-zhi

    2005-04-15

    To observe the treating effect of collage-heparin sulfate after the 10 mm rat sciatic nerve defect was bridged by it. A new kind of nervous tissue engineering scaffold was produced by freeze-drying technique from collagen-heparin sulfate. Thirty-two SD rats were randomly divided into A, B, C and D groups. Sciatic nerve defect in group A was bridged by collagen-heparin sulfate. In group B, sciatic nerve was bridged by auto-nerve transplantation. Group C was the blank control group. Animals in group D were normal. And 10 mm sciatic nerve defect was bridged in the experiment. Thirty-six weeks after the operation, the experimental animals were detected by HRP labeled retrograde trace, HE staining, toluidine staining, silvering staining, S100, GAP-43 and NF immunohistological staining, MBP immunofluorescence staining and transmission electron microscope to observe the nerve regeneration inducing effect of this new scaffold. Nine months after operation, the collage-heparin sulfate scaffold was replaced by newly regenerated nerve. The number of HRP labeled spinal cord anterior horn cells and the area of sensation nerve fiber at the posterior horn were similar with that was repaired by auto-nerve. GAP-43, NF and S100 labeled regenerated nerve fiber had passed the total scaffold and entered the distal terminal. The regenerated nerve fibers were paralleled, lineage arranged, coincide with the prearranged regenerating "channel" in the collagen-heparin sulfate scaffold. MBP immunofluorescence staining also proved that the newly regenerated nerve fiber could be ensheathed. In the experimental group, the area of myelinated nerve fiber and the thickness of the myelin sheath had no obvious difference with that of the group repaired by auto-nerve, except that the density of the regenerated myelinated sheath fiber was lower than that of the control group. Nervous tissue engineering scaffold produced by collagen-heparin sulfate can guide the regeneration of nerve fibers. The nerve

  17. Missing texture reconstruction method based on error reduction algorithm using Fourier transform magnitude estimation scheme.

    Science.gov (United States)

    Ogawa, Takahiro; Haseyama, Miki

    2013-03-01

    A missing texture reconstruction method based on an error reduction (ER) algorithm, including a novel estimation scheme of Fourier transform magnitudes is presented in this brief. In our method, Fourier transform magnitude is estimated for a target patch including missing areas, and the missing intensities are estimated by retrieving its phase based on the ER algorithm. Specifically, by monitoring errors converged in the ER algorithm, known patches whose Fourier transform magnitudes are similar to that of the target patch are selected from the target image. In the second approach, the Fourier transform magnitude of the target patch is estimated from those of the selected known patches and their corresponding errors. Consequently, by using the ER algorithm, we can estimate both the Fourier transform magnitudes and phases to reconstruct the missing areas.

  18. Prolonged Activated Clotting Time after Protamine Administration Does Not Indicate Residual Heparinization after Cardiopulmonary Bypass in Pediatric Open Heart Surgery.

    Science.gov (United States)

    Yamamoto, Tomohiro; Wolf, Hans-Gerd; Sinzobahamvya, Nicodème; Asfour, Boulos; Hraska, Victor; Schindler, Ehrenfried

    2015-08-01

    In open heart surgery, heparinization is commonly neutralized using an empirical heparin:protamine ratio ranging between 1:1 and 1:1.5. However, these ratios may result in protamine overdose that should be avoided for its negative side effects on the coagulation system. This study aimed to indicate the appropriate treatment for prolonged activated clotting time (ACT) after protamine administration following cardiopulmonary bypass (CPB) in pediatric open heart surgery by investigating the underlying reasons for it. Twenty-seven children (open heart surgery were included. Heparin was administered only before CPB (400 IU/kg) and in the pump priming volume for CPB (2,000 IU) and was neutralized by 1:1 protamine after CPB. The blood heparin concentration was measured using anti-Xa assay. ACT and blood concentrations of heparin, coagulation factors, thrombin-antithrombin complex, and prothrombin fragment 1 + 2 were assessed. A rotational thromboelastometry (ROTEM; Tem International GmbH, München, Bayern, Germany) was used to confirm the coagulation status and residual heparin after protamine administration. Anti-Xa assay showed that there is no residual heparin in the blood after 1:1 protamine administration. Nevertheless, ACT (128.89 ± 3.09 seconds before heparin administration) remained prolonged (177.14 ± 5.43 seconds at 10 minutes after protamine, 182.00 ± 5.90 seconds at 30 minutes after protamine). The blood concentrations of coagulation factors were significantly lower than those before heparin administration (p < 0.01). The low FIBTEM MCF of ROTEM (4.43 ± 0.32 mm) at 10 minutes after protamine indicated low fibrinogen concentration. Prolonged ACT after heparin neutralization by 1:1 protamine administration does not necessarily indicate residual heparin, but low blood concentrations of coagulation factors should be considered as a reason as well. Accordingly, supply of coagulation factors instead of additional protamine should be

  19. Farmacovigilância da heparina no Brasil Heparin pharmacovigilance in Brazil

    Directory of Open Access Journals (Sweden)

    Daniela Rezende Garcia Junqueira

    2011-06-01

    Full Text Available OBJETIVO: Investigar a origem das preparações de heparina, na forma farmacêutica injetável, disponíveis no mercado brasileiro, discutindo o impacto do perfil dos produtos comercializados e das alterações na monografia da heparina na segurança do fármaco. MÉTODOS: Pesquisou-se o banco de dados de Produtos Registrados das Empresas de Medicamentos da Anvisa e o Dicionário de Especialidades Farmacêuticas (DEF 2008/2009. Foi realizado inquérito com as indústrias com autorização ativa para o comércio do fármaco no Brasil. RESULTADOS: Cinco indústrias possuem autorização para o comércio de heparina não fracionada no Brasil. Três são de origem suína e duas de origem bovina, sendo que apenas uma possui essa informação explicitada na bula. A efetividade e a segurança da heparina, estudadas em populações estrangeiras, podem não representar a nossa realidade, já que a maioria dos países não produz a heparina bovina. A heparina atualmente comercializada tem, ainda, aproximadamente 10% menos atividade anticoagulante que a anteriormente produzida, e essa alteração pode ter implicações clínicas. CONCLUSÃO: Evidências acerca da ausência de intercambialidade de doses entre as heparinas de origem bovina e suína e o diferenciado perfil de segurança entre esses fármacos indicam necessidade de acompanhamento do tratamento e da resposta dos pacientes. Eventos que ameacem a segurança do paciente devem ser comunicados ao sistema da farmacovigilância do país.OBJECTIVE: To investigate the biological origin of injectable unfractioned heparin available in Brazilian market by discussing the impact of the profile of commercial products and the changes in heparin monograph on the drug safety. METHODS: The Anvisa data base for the Registered Products of Pharmaceutical Companies and the Dictionary of Pharmaceutical Specialties (DEF 2008/2009 were searched. A survey with industries having an active permission for marketing the drug

  20. Inversion of lithium heparin gel tubes after centrifugation is a significant source of bias in clinical chemistry testing.

    Science.gov (United States)

    Lippi, Giuseppe; Salvagno, Gian Luca; Danese, Elisa; Lima-Oliveira, Gabriel; Brocco, Giorgio; Guidi, Gian Cesare

    2014-09-25

    This study was planned to establish whether random orientation of gel tubes after centrifugation may impair sample quality. Eight gel tubes were collected from 17 volunteers: 2 Becton Dickinson (BD) serum tubes, 2 Terumo serum tubes, 2 BD lithium heparin tubes and 2 Terumo lithium heparin tubes. One patient's tube for each category was kept in a vertical, closure-up position for 90 min ("upright"), whereas paired tubes underwent bottom-up inversion every 15 min, for 90 min ("inverted"). Immediately after this period of time, 14 clinical chemistry analytes, serum indices and complete blood count were then assessed in all tubes. Significant increases were found for phosphate and lipaemic index in all inverted tubes, along with AST, calcium, cholesterol, LDH, potassium, hemolysis index, leukocytes, erythrocytes and platelets limited to lithium heparin tubes. The desirable quality specifications were exceeded for AST, LDH, and potassium in inverted lithium heparin tubes. Residual leukocytes, erythrocytes, platelets and cellular debris were also significantly increased in inverted lithium heparin tubes. Lithium heparin gel tubes should be maintained in a vertical, closure-up position after centrifugation. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Efficacy of a protocol including heparin ointment for treatment of multikinase inhibitor-induced hand-foot skin reactions.

    Science.gov (United States)

    Li, Jian-ri; Yang, Chi-rei; Cheng, Chen-li; Ho, Hao-chung; Chiu, Kun-yuan; Su, Chung-Kuang; Chen, Wen-Ming; Wang, Shian-Shiang; Chen, Chuan-Shu; Yang, Cheng-Kuang; Ou, Yen-chuan

    2013-03-01

    The purpose of this study is to evaluate the efficacy of a protocol including topical heparin therapy for hand-foot skin reactions (HFSR) during multikinase (MKI) treatment. We prospectively collected 26 patients who had HFSRs during treatment with the MKIs, sunitinib, sorafenib, or axitinib. The age distribution ranged from 46 to 87 years, with a mean of 66 years. The distribution of HFSR severity was 12 patients with grade 1, 12 with grade 2, and 2 with grade 3. A heparin-containing topical ointment treatment, combined with hand-foot shock absorbers and skin moisturizers, was used at the lesion sites. Changes in the grade of HFSR, MKI dosage, and interruptions of MKI therapy were recorded. The results showed that 66.7% of grade 1 patients were cured of disease, 83.3% of grade 2 patients had improved symptoms, and both grade 3 patients (100%) had improved symptoms and were downgraded to grade 2. Four (15.4%) patients required reduction of MKI dosage, but there were no treatment interruptions or dropouts. Our protocol is beneficial in promoting resolution of HFSRs induced by MKIs. Further validation in large control studies should be investigated.

  2. Immobilized enzymes to convert N-sulfo, N-acetyl heparosan to a critical intermediate in the production of bioengineered heparin.

    Science.gov (United States)

    Xiong, Jian; Bhaskar, Ujjwal; Li, Guoyun; Fu, Li; Li, Lingyun; Zhang, Fuming; Dordick, Jonathan S; Linhardt, Robert J

    2013-09-10

    Heparin is a critically important anticoagulant drug that is prepared from pig intestine. In 2007-2008, there was a crisis in the heparin market when the raw material was adulterated with the toxic polysaccharide, oversulfated chondroitin sulfate, which was associated with 100 deaths in the U.S. alone. As the result of this crisis, our laboratory and others have been actively pursuing alternative sources for this critical drug, including synthetic heparins and bioengineered heparin. In assessing the bioengineering processing costs it has become clear that the use of both enzyme-catalyzed cofactor recycling and enzyme immobilization will be needed for commercialization. In the current study, we examine the use of immobilization of C₅-epimerase and 2-O-sulfotransferase involved in the first enzymatic step in the bioengineered heparin process, as well as arylsulfotransferase-IV involved in cofactor recycling in all three enzymatic steps. We report the successful immobilization of all three enzymes and their use in converting N-sulfo, N-acetyl heparosan into N-sulfo, N-acetyl 2-O-sulfo heparin. Copyright © 2013 Elsevier B.V. All rights reserved.

  3. A new biocompatible delivery scaffold containing heparin and bone morphogenetic protein 2

    Directory of Open Access Journals (Sweden)

    Thanyaphoo Suphannee

    2016-09-01

    Full Text Available Silicon-substituted calcium phosphate (Si-CaP was developed in our laboratory as a biomaterial for delivery in bone tissue engineering. It was fabricated as a 3D-construct of scaffolds using chitosan-trisodium polyphosphate (TPP cross-linked networks. In this study, heparin was covalently bonded to the residual -NH2 groups of chitosan on the scaffold applying carbodiimide chemistry. Bonded heparin was not leached away from scaffold surfaces upon vigorous washing or extended storage. Recombinant human bone morphogenetic protein 2 (rhBMP-2 was bound to conjugated scaffolds by ionic interactions between the negatively charged SO42- clusters of heparin and positively charged amino acids of rhBMP-2. The resulting scaffolds were inspected for bone regenerative capacity by subcutaneous implanting in rats. Histological observation and mineralization assay were performed after 4 weeks of implantation. Results from both in vitro and in vivo experiments suggest the potential of the developed scaffolds for bone tissue engineering applications in the future.

  4. Managing cancer-related venous thromboembolic disease: low-molecular-weight heparins and beyond.

    Science.gov (United States)

    O'Connell, Casey L; Liebman, Howard A

    2008-12-01

    Venous thromboembolism is a major contributor to the morbidity and mortality of patients with cancer. For patients undergoing cancer surgery, several trials support the safety and efficacy of unfractionated heparin and of low-molecular-weight heparin for the prevention of venous thromboembolism, while data regarding the efficacy and safety of these agents in the setting of medical hospitalization is less definitive and must be extracted from trials including noncancer patients with different thrombotic risk factors. Randomized clinical studies confirm that patients with cancer who develop venous thromboembolism have superior outcomes when treated with long-term low-molecular-weight heparin as compared with warfarin. Novel anticoagulants that are orally bioavailable and function by directly inhibiting factor Xa or thrombin are entering the market. To date, data regarding the efficacy and safety of these novel anticoagulants as venous thromboembolism prophylaxis and treatment in cancer patients are not available and must be extracted from larger trials with heterogeneous patient populations.

  5. Obstacles in the diagnostics and therapy of heparin-induced thrombocytopenia.

    Science.gov (United States)

    Antonijević, Nebojsa M; Radovanović, Nebojsa; Obradović, Slobodan; Vucelić, Dragica; Stojanović, Bojan; Miković, Danijela; Kovac, Mirjana; Kocica, Tina; Tadić, Svetlana; Antonijević, Irina; Drasković, Snezana; Djordjević, Valentina; Calija, Branko; Perunicić, Jovan; Vasiljević, Zorana

    2010-01-01

    An immune-mediated, severe, acquired prothrombotic disorder, heparin-induced thrombocytopenia type II (HIT II) occurs in 0.5-5% of patients exposed to unfractionated heparin longer than 5-7 days. Arterial and venous thromboses are induced by HIT II in about 35-50% of patients. Typical death rate for HIT is about 29%, while 21% of HIT patients result in amputation of a limb. The trend towards the occurrence of HIT due to the administration of low molecular weight heparins (LMWH) taking ever conspicuous place in the standard venous thromboembolism (VTE) prophylaxis has been more frequently observed recently. It is considered that LMWH may cause HIT II in about 0.25-1%. The need for further modification of HIPA assays with LMWH has been imposed in the HIT laboratory diagnostics, heretofore overburdened with complexity. There are several constantly opposing problems arising in HIT laboratory diagnostics, one of which is that in a certain number of patients immunologic assays detect nonpathogenic antibodies (mainly IgM or IgA heparin-PF4 antibodies) while, on the other hand, the occurrence of HIT pathogenetically mediated by minor antigens (neutrophil-activating peptide 2 or interleukin 8) may be neglected in certain cases. The following factors play an important role in the interpretation of each laboratory HIT assays performed: 1. correlation with HIT clinical probability test, the best known of which is 4T'score, 2. the interpretation of the laboratory findings dependent on the time of the thrombocytopenia onset, as well as 3. the sensitivity and specificity of each test respectively. The HIT diagnostics in the presence of other comorbid states which may also induce thrombocytopenia, more precisely known as pseudo HIT (cancer, sepsis, disseminated intravascular coagulation, pulmonary embolism, antiphospholipid syndrome, etc), represents a specific clinical problem.

  6. The physiologic and therapeutic role of heparin in implantation and placentation

    Directory of Open Access Journals (Sweden)

    Michela Quaranta

    2015-01-01

    Full Text Available Implantation, trophoblast development and placentation are crucial processes in the establishment and development of normal pregnancy. Abnormalities of these processes can lead to pregnancy complications known as the great obstetrical syndromes: preeclampsia, intrauterine growth restriction, fetal demise, premature prelabor rupture of membranes, preterm labor, and recurrent pregnancy loss. There is mounting evidence regarding the physiological and therapeutic role of heparins in the establishment of normal gestation and as a modality for treatment and prevention of pregnancy complications. In this review, we will summarize the properties and the physiological contributions of heparins to the success of implantation, placentation and normal pregnancy.

  7. Protein interactions with quaternized chitosan/heparin multilayers

    Czech Academy of Sciences Publication Activity Database

    Kumorek, Marta M.; Kubies, Dana; Riedel, Tomáš

    2016-01-01

    Roč. 65, Suppl. 2 (2016), S253-S261 ISSN 0862-8408 R&D Projects: GA MŠk(CZ) LQ1604 Institutional support: RVO:61389013 Keywords : heparin * chitosan * protein Subject RIV: EB - Genetics ; Molecular Biology Impact factor: 1.461, year: 2016 http://www.biomed.cas.cz/physiolres/pdf/65%20Suppl%202/65_S253.pdf

  8. Basic fibroblast growth factor binds to subendothelial extracellular matrix and is released by heparitinase and heparin-like molecules

    International Nuclear Information System (INIS)

    Bashkin, P.; Doctrow, S.; Klagsbrun, M.; Svahn, C.M.; Folkman, J.; Vlodavsky, I.

    1989-01-01

    Basic fibroblast growth factor (bFGF) exhibits specific binding to the extracellular matrix (ECM) produced by cultured endothelial cells. Binding was saturable as a function both of time and of concentration of 125 I-bFGF. Scatchard analysis of FGF binding revealed the presence of about 1.5 x 10 12 binding sites/mm 2 ECM with an apparent k D of 610 nM. FGF binds to heparan sulfate (HS) in ECM as evidenced by (i) inhibition of binding in the presence of heparin or HS at 0.1-1 μg/mL, but not by chondroitin sulfate, keratan sulfate, or hyaluronic acid at 10 μg/mL, (ii) lack of binding to ECM pretreated with heparitinase, but not with chondroitinase ABC, and (iii) rapid release of up to 90% of ECM-bound FGF by exposure to heparin, HS, or heparitinase, but not to chondroitin sulfate, keratan sulfate, hyaluronic acid, or chondroitinase ABC. Oligosaccharides derived from depolymerized heparin, and as small as the tetrasaccharide, released the ECM-bound FGF, but there was little or no release of FGF by modified nonanticoagulant heparins such as totally desulfated heparin, N-desulfated heparin, and N-acetylated heparin. FGF released from ECM was biologically active, as indicated by its stimulation of cell proliferation and DNA synthesis in vascular endothelial cells and 3T3 fibroblasts. Similar results were obtained in studies on release of endogenous FGF-like mitogenic activity from Descement's membranes of bovine corneas. It is suggested that ECM storage and release of bFGF provide a novel mechanism for regulation of capillary blood vessel growth. Whereas ECM-bound FGF may be prevented from acting on endothelial cells, its displacement by heparin-like molecules and/or HS-degrading enzymes may elicit a neovascular response

  9. The N-terminal of a heparin-binding sperm membrane mitogen possess lectin-like sequence

    International Nuclear Information System (INIS)

    Mor, Visesato; Chatterjee, Tapati

    2007-01-01

    Glycosaminoglycans like heparin and heparin sulfate in follicular fluid induce changes in the intracellular environment during the spermatozoal functional maturation. We previously reported the isolation, purification and partial characterization of a heparin binding sperm membrane protein (HBSM). In the present study, the amino acids analysis provided evidence of a single sequence, which suggest the homogeneity of the purified HBSM. Fourteen amino acids- 1 A D T I V A V E L D T Y P N 14 -correspond to the amino terminal sequence of Concanavalin A (Con A) and contain 45.2% carbohydrate by weight. HBSM possess mitogenic property on lymphocytes with comparable magnitude to the well-known mitogen; Con A, inducing 83% radiolabel thymidine incorporation in growing lymphocytes. Unlike Con A, there was no agglutination of cell by HBSM upto 5 ng/ml concentration. Interestingly, we found that heparin and chondroitin sulfate-conjugated HBSM inhibit the proliferative activity. Similar effect was also found with an in-house isolate sulfated glycans; G-I (28% sulfate). In contrast, there was no inhibition by the desulfated form; G-ID. Altogether, our data suggest that the mechanism of cell proliferative pathway may be different for HBSM and Con A

  10. An Algorithmic Comparison of the Hyper-Reduction and the Discrete Empirical Interpolation Method for a Nonlinear Thermal Problem

    Directory of Open Access Journals (Sweden)

    Felix Fritzen

    2018-02-01

    Full Text Available A novel algorithmic discussion of the methodological and numerical differences of competing parametric model reduction techniques for nonlinear problems is presented. First, the Galerkin reduced basis (RB formulation is presented, which fails at providing significant gains with respect to the computational efficiency for nonlinear problems. Renowned methods for the reduction of the computing time of nonlinear reduced order models are the Hyper-Reduction and the (Discrete Empirical Interpolation Method (EIM, DEIM. An algorithmic description and a methodological comparison of both methods are provided. The accuracy of the predictions of the hyper-reduced model and the (DEIM in comparison to the Galerkin RB is investigated. All three approaches are applied to a simple uncertainty quantification of a planar nonlinear thermal conduction problem. The results are compared to computationally intense finite element simulations.

  11. Assessment of anti-factor Xa activity of heparin in binary parenteral nutrition admixtures for premature neonates.

    Science.gov (United States)

    Foinard, A; Perez, M; Barthélémy, C; Lannoy, D; Flamein, F; Storme, L; Tournoys, A; Décaudin, B; Odou, P

    2015-07-01

    An in vitro study was carried out to determine the anti-Xa activity of heparin in binary parenteral nutrition (BPN) admixtures for premature neonates in our neonatal intensive care unit (NICU) after a 24-hour infusion, as well as to assess drug interaction with a 50% glucose solution. Two types of bags were prepared: (1) BPN admixtures (composition defined in the NICU) including sodium heparin at 77 UI/mL and (2) bags containing only G50% with sodium heparin at 193 UI/mL. The anti-Xa activity of heparin was measured in bags at T0, after the 24-hour infusion and in eluates at the outlet of the infusion line after 24hours, using a validated chromogenic anti-Xa method. Comparisons of the mean concentration observed with the theoretical value for anti-Xa activity were performed with the Student t-test. Mean values of anti-Xa activity do not differ significantly from the values expected for all conditions. We found a slight variation in anti-Xa activity when infused over 24hours for both types of bags, with and without in-line filtration, showing that heparin remains stable during this infusion period in both BPN admixtures and G50%. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  12. Coherency Identification of Generators Using a PAM Algorithm for Dynamic Reduction of Power Systems

    Directory of Open Access Journals (Sweden)

    Seung-Il Moon

    2012-11-01

    Full Text Available This paper presents a new coherency identification method for dynamic reduction of a power system. To achieve dynamic reduction, coherency-based equivalence techniques divide generators into groups according to coherency, and then aggregate them. In order to minimize the changes in the dynamic response of the reduced equivalent system, coherency identification of the generators should be clearly defined. The objective of the proposed coherency identification method is to determine the optimal coherent groups of generators with respect to the dynamic response, using the Partitioning Around Medoids (PAM algorithm. For this purpose, the coherency between generators is first evaluated from the dynamic simulation time response, and in the proposed method this result is then used to define a dissimilarity index. Based on the PAM algorithm, the coherent generator groups are then determined so that the sum of the index in each group is minimized. This approach ensures that the dynamic characteristics of the original system are preserved, by providing the optimized coherency identification. To validate the effectiveness of the technique, simulated cases with an IEEE 39-bus test system are evaluated using PSS/E. The proposed method is compared with an existing coherency identification method, which uses the K-means algorithm, and is found to provide a better estimate of the original system. 

  13. Disappearance of a low molecular weight heparin fraction (CY 216) differs from standard heparin in rabbits

    International Nuclear Information System (INIS)

    Boneu, B.; Buchanan, M.R.; Caranobe, C.; Gabaig, A.M.; Dupouy, D.; Sie, P.; Hirsh, J.

    1987-01-01

    In previous studies, we have reported that standard heparin (SH) was cleared by two mechanisms, a saturable mechanism which predominated at low doses (less than 100 anti-factor Xa U/kg) and a non-saturable mechanism which predominated at higher doses, when the first mechanism became saturated. In this study, we examined the importance of these two mechanisms in the disappearance of a low molecular weight heparin fraction (LMWH) (CY 216), by comparing the pharmacokinetics and the pharmacodynamics of a wide range of doses of SH and CY 216 (1.5 to 500 anti-factor Xa U/kg). Pharmacokinetics was measured as the disappearance of 125 I-radiolabelled SH or CY 216. Pharmacodynamics was measured as the disappearance of the anti-factor Xa activity of SH and CY 216. We found that the saturable mechanism contributed little to the disappearance of CY 216 and that it was cleared predominantly by the non-saturable mechanism at all doses tested. Thus, at low doses (less than 100 anti-factor Xa U/kg), SH was cleared more rapidly than CY 216, whereas at higher doses, CY 216 was cleared more rapidly than SH. We conclude that the mechanism of disappearance of LMWH's differ significantly from those of SH, and that this difference may explain the apparent prolonged anticoagulant activity of LMWH's within the therapeutic range doses

  14. Platelet-derived growth factor inhibits platelet activation in heparinized whole blood.

    Science.gov (United States)

    Selheim, F; Holmsen, H; Vassbotn, F S

    1999-08-15

    We previously have demonstrated that human platelets have functionally active platelet-derived growth factor alpha-receptors. Studies with gel-filtered platelets showed that an autocrine inhibition pathway is transduced through this tyrosine kinase receptor during platelet activation. The physiological significance of this inhibitory effect of platelet-derived growth factor on gel-filtered platelets activation is, however, not known. In the present study, we investigated whether platelet-derived growth factor inhibits platelet activation under more physiological conditions in heparinized whole blood, which represents a more physiological condition than gel-filtered platelets. Using flow cytometric assays, we demonstrate here that platelet-derived growth factor inhibits thrombin-, thrombin receptor agonist peptide SFLLRN-, and collagen-induced platelet aggregation and shedding of platelet-derived microparticles from the platelet plasma membrane during platelet aggregation in stirred heparinized whole blood. The inhibitory effect of platelet-derived growth factor was dose dependent. However, under nonaggregating conditions (no stirring), we could not demonstrate any significant effect of platelet-derived growth factor on thrombin- and thrombin receptor agonist peptide-induced platelet surface expression of P-selectin. Our results demonstrate that platelet-derived growth factor appears to be a true antithrombotic agent only under aggregating conditions in heparinized whole blood.

  15. Influences of apolipoprotein E on soluble and heparin-immobilized hepatic lipase

    International Nuclear Information System (INIS)

    Landis, B.A.; Rotolo, F.S.; Meyers, W.C.; Clark, A.B.; Quarfordt, S.H.

    1987-01-01

    The effect of human apolipoprotein E (apoE), either alone or in combination with apoC, on the lipolysis of a radiolabeled triglyceride emulsion was studied with hepatic lipase in solution and immobilized on heparin-Sepharose. The soluble hepatic lipase was inhibited, whereas the heparin-immobilized lipase was stimulated by apoE. This stimulation was attenuated by combining apoE with either apoC-II or C-III. The heparin-immobilized lipase demonstrated much less lipolysis of the zwitterionic phosphatidylcholine-stabilized triglyceride emulsion than did the soluble enzyme. This difference was less when the emulsion was stabilized by a nonionic detergent. apoE inhibited lipase activity when assayed under conditions (0.4 M NaCl) of bound enzyme and unbound substrate. Increasing the emulsion apoE content beyond optimum inhibited lipolysis by the immobilized enzyme. Kinetic analysis of phosphatidylcholine-stabilized triglyceride emulsions revealed a significant decrease in immobilized enzyme K/sub m/ and an increase in V/sub max/ when the emulsion was supplemented with apoE. Distributing the immobilized lipase in clustered aggregates produced more lipolysis than when the same enzyme content was uniformly bound

  16. The effect of heparin on pregnancy associated plasma protein-A concentration in healthy, non-pregnant individuals

    DEFF Research Database (Denmark)

    Jespersen, Camilla H B; Vestergaard, Kirstine R.; Schou, Morten

    2015-01-01

    Objectives: The objective of this study was to determine the differences in pregnancy associated plasma protein-A (PAPP-A) concentrations in heparin naive and heparin treated healthy men and non-pregnant women, to find a possible difference in different age groups, and to determine the response...

  17. Impact of anticoagulation strategy with bivalirudin or heparin on nonaccess site bleeding in percutaneous coronary interventions: A meta-analysis of randomized trials.

    Science.gov (United States)

    Verdoia, Monica; Barbieri, Lucia; Parodi, Guido; Bellandi, Benedetta; Schaffer, Alon; Suryapranata, Harry; De Luca, Giuseppe

    2017-10-01

    Transradial approach has significantly decreased the rate of access site bleeding in patients undergoing percutaneous coronary interventions (PCI), therefore potentially mitigating the benefits offered by bivalirudin in lowering major bleeding complications as compared to heparin. However, nonaccess site bleeding, that represent the majority of hemorrhagic complications, still carry negative prognostic consequences for these patients and no study has so far defined the exact impact of bivalirudin on nonaccess site bleeding, that was therefore the aim of present meta-analysis. Literature archives (Pubmed, EMBASE, Cochrane) and main scientific sessions were scanned comparing bivalirudin vs. heparin in patients undergoing PCI. Primary endpoint was the occurrence of nonaccess site bleeding within 30 days. Secondary endpoints were 30 days mortality and the occurrence of access-site bleeding. A total of nine randomized clinical trials were finally included, involving 32,587 patients, 55.8% randomized to bivalirudin. Bivalirudin significantly reduced the rate of nonaccess site bleeding (2.6 vs. 3.8%, OR [95% CI] = 0.68 [0.60-0.77], P site bleeding (OR [95% CI] = 0.67 [0.57-0.79], P translate into mortality benefits (OR [95% CI] = 0.89 [0.76-1.05], P = 0.18; P het  = 0.12; r = 0.21 (-1.12; 1.53), P = 0.76). The present meta-analysis shows that bivalirudin can provide a significant reduction of both access and nonaccess site bleeding in patients undergoing PCI. However, these hemorrhagic benefits did not impact on survival, and moreover, were significantly conditioned by the association of heparin with potent antithrombotic strategies, such as glycoprotein IIbIIIa inhibitors, rather than by heparin or bivalirudin alone. Therefore, we could not provide any clinical evidence for the routine use of bivalirudin as preferred anticoagulation strategy for PCI. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  18. Adaptive iterative dose reduction algorithm in CT: Effect on image quality compared with filtered back projection in body phantoms of different sizes

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Milim; Lee, Jeong Min; Son, Hyo Shin; Han, Joon Koo; Choi, Byung Ihn [College of Medicine, Seoul National University, Seoul (Korea, Republic of); Yoon, Jeong Hee; Choi, Jin Woo [Dept. of Radiology, Seoul National University Hospital, Seoul (Korea, Republic of)

    2014-04-15

    To evaluate the impact of the adaptive iterative dose reduction (AIDR) three-dimensional (3D) algorithm in CT on noise reduction and the image quality compared to the filtered back projection (FBP) algorithm and to compare the effectiveness of AIDR 3D on noise reduction according to the body habitus using phantoms with different sizes. Three different-sized phantoms with diameters of 24 cm, 30 cm, and 40 cm were built up using the American College of Radiology CT accreditation phantom and layers of pork belly fat. Each phantom was scanned eight times using different mAs. Images were reconstructed using the FBP and three different strengths of the AIDR 3D. The image noise, the contrast-to-noise ratio (CNR) and the signal-to-noise ratio (SNR) of the phantom were assessed. Two radiologists assessed the image quality of the 4 image sets in consensus. The effectiveness of AIDR 3D on noise reduction compared with FBP were also compared according to the phantom sizes. Adaptive iterative dose reduction 3D significantly reduced the image noise compared with FBP and enhanced the SNR and CNR (p < 0.05) with improved image quality (p < 0.05). When a stronger reconstruction algorithm was used, greater increase of SNR and CNR as well as noise reduction was achieved (p < 0.05). The noise reduction effect of AIDR 3D was significantly greater in the 40-cm phantom than in the 24-cm or 30-cm phantoms (p < 0.05). The AIDR 3D algorithm is effective to reduce the image noise as well as to improve the image-quality parameters compared by FBP algorithm, and its effectiveness may increase as the phantom size increases.

  19. Adaptive iterative dose reduction algorithm in CT: Effect on image quality compared with filtered back projection in body phantoms of different sizes

    International Nuclear Information System (INIS)

    Kim, Milim; Lee, Jeong Min; Son, Hyo Shin; Han, Joon Koo; Choi, Byung Ihn; Yoon, Jeong Hee; Choi, Jin Woo

    2014-01-01

    To evaluate the impact of the adaptive iterative dose reduction (AIDR) three-dimensional (3D) algorithm in CT on noise reduction and the image quality compared to the filtered back projection (FBP) algorithm and to compare the effectiveness of AIDR 3D on noise reduction according to the body habitus using phantoms with different sizes. Three different-sized phantoms with diameters of 24 cm, 30 cm, and 40 cm were built up using the American College of Radiology CT accreditation phantom and layers of pork belly fat. Each phantom was scanned eight times using different mAs. Images were reconstructed using the FBP and three different strengths of the AIDR 3D. The image noise, the contrast-to-noise ratio (CNR) and the signal-to-noise ratio (SNR) of the phantom were assessed. Two radiologists assessed the image quality of the 4 image sets in consensus. The effectiveness of AIDR 3D on noise reduction compared with FBP were also compared according to the phantom sizes. Adaptive iterative dose reduction 3D significantly reduced the image noise compared with FBP and enhanced the SNR and CNR (p < 0.05) with improved image quality (p < 0.05). When a stronger reconstruction algorithm was used, greater increase of SNR and CNR as well as noise reduction was achieved (p < 0.05). The noise reduction effect of AIDR 3D was significantly greater in the 40-cm phantom than in the 24-cm or 30-cm phantoms (p < 0.05). The AIDR 3D algorithm is effective to reduce the image noise as well as to improve the image-quality parameters compared by FBP algorithm, and its effectiveness may increase as the phantom size increases.

  20. Proteomic analysis of heparin-binding proteins from human seminal ...

    Indian Academy of Sciences (India)

    Prakash

    (MALDI TOF/MS) for protein analysis of human HBPs. We resolved 70 ... Thus, the combined effects of seminal plasma components support the survival of ...... The BBXB motif of RANTES is the principal site for heparin binding and controls ...

  1. Vitamin K antagonists or low-molecular-weight heparin for the long term treatment of symptomatic venous thromboembolism

    NARCIS (Netherlands)

    van der Heijden, J. F.; Hutten, B. A.; Büller, H. R.; Prins, M. H.

    2002-01-01

    BACKGROUND: People with venous thromboembolism are generally treated for five days with intravenous unfractionated heparin or subcutaneous low-molecular-weight heparin followed by three months of vitamin K antagonists treatment. Treatment with vitamin K antagonists requires regular laboratory

  2. Safety and potential anticoagulant effects of nebulised heparin in burns patients with inhalational injury at Singapore General Hospital Burns Centre.

    Science.gov (United States)

    Yip, Lian Yee; Lim, Yen Fang; Chan, Hong Ngee

    2011-11-01

    Nebulised heparin, N-acetylcysteine (NAC) and salbutamol were shown to decrease reintubation rates, incidence of atelectasis and mortality in paediatric patients and reduce lung injury scores in adult burns patients with inhalational lung injury (ILI). Nebulised heparin, NAC and salbutamol treatment protocol was introduced in Singapore General Hospital (SGH) Burns Centre in 2006. However, safety data on the use of nebulised heparin and NAC for burns patients with ILI is not well established. In this study, we investigated the safety and potential anticoagulant effects of nebulised heparin in burns patients with ILI. A retrospective study with historical control was conducted. The treatment group consisted of 52 mechanically ventilated adult patients, with a diagnosis of ILI as confirmed by bronchoscopy, admitted to burn intensive care unit (BICU) from the year 2006 to 2009. The group was treated with nebulised heparin, NAC and salbutamol. The control group consists of 11 mechanically ventilated BICU ILI patients treated from year 2001 to 2005 before protocol initiation. Blood coagulation indices (prothrombin time (PT), activated partial thromboplastin time (APTT) and platelet count) were monitored and bleeding incidences were assessed. Blood coagulation indices did not suggest an increase risk of bleeding with nebulised heparin. The APTT, PT and platelet count followed a similar trend for both groups over 7 days. No clinically significant increase in bleeding risk was found to be associated with nebulised heparin. Nebulised heparin was not found to potentiate the risk of bleeding in burns patients with ILI. Copyright © 2011 Elsevier Ltd and ISBI. All rights reserved.

  3. ADRIAMYCIN-LOADED ALBUMIN-HEPARIN CONJUGATE MICROSPHERES FOR INTRAPERITONEAL CHEMOTHERAPY

    NARCIS (Netherlands)

    CREMERS, HFM; SEYMOUR, LW; LAM, K; LOS, G; KWON, G; BAE, YH; KIM, SW; FEIJEN, J

    1994-01-01

    Adriamycin-loaded albumin-heparin conjugate microspheres (ADR-AHCMS) were evaluated as possible intraperitoneal (i.p.) delivery systems for site-specific cytotoxic action. The biocompatibility of the microspheres after intraperitoneal injection was tested first. 1 day after i.p. administration of

  4. Detection of growth factor binding to gelatin and heparin using a photonic crystal optical biosensor

    International Nuclear Information System (INIS)

    Morgan, Abby W.; Chan, Leo L.; Sendemir-Urkmez, Aylin; Cunningham, Brian T.; Jamison, Russell D.

    2010-01-01

    Drug-carrier interactions are important to protein controlled release systems to protect the protein from denaturation and ensure properly timed release. A novel photonic crystal biosensor was used to investigate a gelatin-protein controlled release system to determine the amount of protein bound to the carrier at physiological conditions. The Biomolecular Interaction Detection (BIND) system reflects a narrow band of wavelengths when white light is shone incident to the grating. As mass is deposited onto the surface, the peak wavelength value is shifted due to changes in the optical density of the biosensor. The BIND system was used to detect the binding of growth factors onto acidic gelatin, basic gelatin, and heparin on the sensor surface. Through a series of experiments, including functionalizing the sensor, adjusting the ionic strength of the solution, adjusting the substrate concentration, and minimizing non-specific signal, the adsorption of the gelatins and heparin on the sensor was enhanced. The binding interaction of recombinant human transforming growth factor (rhTGF)-β1 and bone morphogenetic protein (rhBMP)-2 with the two types of gelatin and heparin were investigated. The strength of the interaction between rhTGF-β1 and the substrates is in the following order: heparin > acidic gelatin > basic gelatin. RhBMP-2 bound to the substrates but with less intensity than TGF-β1: heparin > basic gelatin > acidic gelatin. This work provides support for the controlled release mechanism through degradation of the gelatin carrier.

  5. Robust frequency diversity based algorithm for clutter noise reduction of ultrasonic signals using multiple sub-spectrum phase coherence

    Energy Technology Data Exchange (ETDEWEB)

    Gongzhang, R.; Xiao, B.; Lardner, T.; Gachagan, A. [Centre for Ultrasonic Engineering, University of Strathclyde, Glasgow, G1 1XW (United Kingdom); Li, M. [School of Engineering, University of Glasgow, Glasgow, G12 8QQ (United Kingdom)

    2014-02-18

    This paper presents a robust frequency diversity based algorithm for clutter reduction in ultrasonic A-scan waveforms. The performance of conventional spectral-temporal techniques like Split Spectrum Processing (SSP) is highly dependent on the parameter selection, especially when the signal to noise ratio (SNR) is low. Although spatial beamforming offers noise reduction with less sensitivity to parameter variation, phased array techniques are not always available. The proposed algorithm first selects an ascending series of frequency bands. A signal is reconstructed for each selected band in which a defect is present when all frequency components are in uniform sign. Combining all reconstructed signals through averaging gives a probability profile of potential defect position. To facilitate data collection and validate the proposed algorithm, Full Matrix Capture is applied on the austenitic steel and high nickel alloy (HNA) samples with 5MHz transducer arrays. When processing A-scan signals with unrefined parameters, the proposed algorithm enhances SNR by 20dB for both samples and consequently, defects are more visible in B-scan images created from the large amount of A-scan traces. Importantly, the proposed algorithm is considered robust, while SSP is shown to fail on the austenitic steel data and achieves less SNR enhancement on the HNA data.

  6. Cooperative control of blood compatibility and re-endothelialization by immobilized heparin and substrate topography.

    Science.gov (United States)

    Ding, Yonghui; Yang, Meng; Yang, Zhilu; Luo, Rifang; Lu, Xiong; Huang, Nan; Huang, Pingbo; Leng, Yang

    2015-03-01

    A wide variety of environmental cues provided by the extracellular matrix, including biophysical and biochemical cues, are responsible for vascular cell behavior and function. In particular, substrate topography and surface chemistry have been shown to regulate blood and vascular compatibility individually. The combined impact of chemical and topographic cues on blood and vascular compatibility, and the interplay between these two types of cues, are subjects that are currently being explored. In the present study, a facile polydopamine-mediated approach is introduced for immobilization of heparin on topographically patterned substrates, and the combined effects of these cues on blood compatibility and re-endothelialization are systematically investigated. The results show that immobilized heparin and substrate topography cooperatively modulate anti-coagulation activity, endothelial cell (EC) attachment, proliferation, focal adhesion formation and endothelial marker expression. Meanwhile, the substrate topography is the primary determinant of cell alignment and elongation, driving in vivo-like endothelial organization. Importantly, combining immobilized heparin with substrate topography empowers substantially greater competitive ability of ECs over smooth muscle cells than each cue individually. Moreover, a model is proposed to elucidate the cooperative interplay between immobilized heparin and substrate topography in regulating cell behavior. Copyright © 2014 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  7. Heparin binding chitosan derivatives for production of pro-angiogenic hydrogels for promoting tissue healing

    Energy Technology Data Exchange (ETDEWEB)

    Yar, Muhammad, E-mail: drmyar@ciitlahore.edu.pk [Interdisciplinary Research Center in Biomedical Materials, COMSATS Institute of Information Technology, Lahore 54000 (Pakistan); Shahzad, Sohail [Interdisciplinary Research Center in Biomedical Materials, COMSATS Institute of Information Technology, Lahore 54000 (Pakistan); Department of Chemistry, The Islamia University of Bahawalpur, Bahawalpur 63100 (Pakistan); Shahzadi, Lubna [Interdisciplinary Research Center in Biomedical Materials, COMSATS Institute of Information Technology, Lahore 54000 (Pakistan); Shahzad, Sohail Anjum [Department of Chemistry, COMSATS Institute of Information Technology, Abbottabad 22060 (Pakistan); Mahmood, Nasir [Department of Allied Health Sciences and Chemical Pathology, University of Health Sciences, Lahore (Pakistan); Department of Human Genetics and Molecular Biology, University of Health Sciences, Lahore (Pakistan); Chaudhry, Aqif Anwar [Interdisciplinary Research Center in Biomedical Materials, COMSATS Institute of Information Technology, Lahore 54000 (Pakistan); Rehman, Ihtesham ur [Interdisciplinary Research Center in Biomedical Materials, COMSATS Institute of Information Technology, Lahore 54000 (Pakistan); Materials Science and Engineering, North Campus, University of Sheffield, Broad Lane, Sheffield S3 7HQ (United Kingdom); MacNeil, Sheila, E-mail: s.macneil@sheffield.ac.uk [Materials Science and Engineering, North Campus, University of Sheffield, Broad Lane, Sheffield S3 7HQ (United Kingdom)

    2017-05-01

    Our aim was to develop a biocompatible hydrogel that could be soaked in heparin and placed on wound beds to improve the vasculature of poorly vascularized wound beds. In the current study, a methodology was developed for the synthesis of a new chitosan derivative (CSD-1). Hydrogels were synthesized by blending CSD-1 for either 4 or 24 h with polyvinyl alcohol (PVA). The physical/chemical interactions and the presence of specific functional groups were confirmed by Fourier transform infrared (FT-IR) spectroscopy and proton nuclear magnetic resonance ({sup 1}H NMR). The porous nature of the hydrogels was confirmed by scanning electron microscopy (SEM). Thermal gravimetric analysis (TGA) showed that these hydrogels have good thermal stability which was slightly increased as the blending time was increased. Hydrogels produced with 24 h of blending supported cell attachment more and could be loaded with heparin to induce new blood vessel formation in a chick chorionic allantoic membrane assay. - Highlights: • Chitosan based hydrogels were designed to stimulate angiogenesis. • Two new derivatives of chitosan were produced using a Mannich type reaction. • Blending a chitosan derivative with PVA gave a porous biocompatible hydrogel. • Heparin bound to the hydrogel on immersion changing its morphology. • Heparin loaded hydrogel stimulated blood vessel formation in a chick model.

  8. Heparin sodium compliance to USP monograph: structural elucidation of an atypical 2.18 ppm NMR signal.

    Science.gov (United States)

    Mourier, Pierre A J; Guichard, Olivier Y; Herman, Fréderic; Viskov, Christian

    2012-01-01

    The ¹H nuclear magnetic resonance (NMR) acceptance criteria in the new heparin US Pharmacopeia (USP) monograph do not take into account potential structural modifications responsible for any extra signals observed in ¹H NMR spectra, some purified heparins may be non-compliant under the proposed new USP guidelines and incorrectly classified as unsuitable for pharmaceutical use. Heparins from the "ES" source, containing an extra signal at 2.18 ppm, were depolymerized under controlled conditions using heparinases I, II, and III. The oligosaccharides responsible for the 2.18 ppm signal were enriched using orthogonal chromatographic techniques. After multiple purification steps, we obtained an oligosaccharide mixture containing a highly enriched octasaccharide bearing the structural modification responsible for the extra signal. Following heparinase I depolymerization, a pure tetrasaccharide containing the fingerprint structural modification was isolated for full structural determination. Using 1D and 2D ¹H NMR spectroscopy, the structural moiety responsible for the extra signal at 2.18 ppm was identified as an acetyl group on the heparin backbone, most likely resulting from a very minor manufacturing process side reaction that esterifies the uronic acid at position 3. Such analytical peculiarity has always been present in this heparin source and it was used safety over the years. Copyright © 2012 Elsevier B.V. All rights reserved.

  9. Histones Differentially Modulate the Anticoagulant and Profibrinolytic Activities of Heparin, Heparin Derivatives, and Dabigatran.

    Science.gov (United States)

    Ammollo, Concetta Tiziana; Semeraro, Nicola; Carratù, Maria Rosaria; Colucci, Mario; Semeraro, Fabrizio

    2016-02-01

    The antithrombin activity of unfractionated heparin (UFH) is offset by extracellular histones, which, along with DNA, represent a novel mediator of thrombosis and a structural component of thrombi. Here, we systematically evaluated the effect of histones, DNA, and histone-DNA complexes on the anticoagulant and profibrinolytic activities of UFH, its derivatives enoxaparin and fondaparinux, and the direct thrombin inhibitor dabigatran. Thrombin generation was assessed by calibrated automated thrombinography, inhibition of factor Xa and thrombin by synthetic substrates, tissue plasminogen activator-mediated clot lysis by turbidimetry, and thrombin-activatable fibrinolysis inhibitor (TAFI) activation by a functional assay. Histones alone delayed coagulation and slightly stimulated fibrinolysis. The anticoagulant activity of UFH and enoxaparin was markedly inhibited by histones, whereas that of fondaparinux was enhanced. Histones neutralized both the anti-Xa and anti-IIa activities of UFH and preferentially blocked the anti-IIa activity of enoxaparin. The anti-Xa activity of fondaparinux was not influenced by histones when analyzed by chromogenic substrates, but was potentiated in a plasma prothrombinase assay. Histones inhibited the profibrinolytic activity of UFH and enoxaparin and enhanced that of fondaparinux by acting on the modulation of TAFI activation by anticoagulants. Histone H1 was mainly responsible for these effects. Histone-DNA complexes, as well as intact neutrophil extracellular traps, impaired the activities of UFH, enoxaparin, and fondaparinux. Dabigatran was not noticeably affected by histones and/or DNA, whatever the assay performed. In conclusion, histones and DNA present in the forming clot may variably influence the antithrombotic activities of anticoagulants, suggesting a potential therapeutic advantage of dabigatran and fondaparinux over heparins. Copyright © 2016 by The American Society for Pharmacology and Experimental Therapeutics.

  10. Spurious hypocalcemia in hemodialysis patients after heparinization. In-vitro formation of calcium soaps.

    Science.gov (United States)

    Godolphin, W; Cameron, E C; Frohlich, J; Price, J D

    1979-02-01

    Patients on long-term hemodialysis via arteriovenous fistula received heparin when the fistula needle was inserted, before a sample of blood was obtained for chemical analysis. The resultant release of lipoprotein lipase activity in vivo and continued lipolytic activity in vitro sometimes produced sufficient free fatty acid to precipitate calcium soaps. The consequent spurious hypocalcemia was most frequently observed when the patients had chylomicronemia. This cause of apparent hypocalcemia was eliminated either by immediate analyses of the blood samples or by obtaining samples before systemic heparinization.

  11. Vitamin K antagonists or low-molecular-weight heparin for the long term treatment of symptomatic venous thromboembolism

    NARCIS (Netherlands)

    van der Heijden, J. F.; Hutten, B. A.; Büller, H. R.; Prins, M. H.

    2000-01-01

    Patients who have had an episode of symptomatic venous thromboembolism are usually treated for at least five days with intravenous unfractionated heparin or subcutaneous low-molecular-weight heparin. Thereafter, they received a three month course of a vitamin K antagonist, with a dose adjusted to

  12. Accelerating the peroxidase-like activity of gold nanoclusters at neutral pH for colorimetric detection of heparin and heparinase activity.

    Science.gov (United States)

    Hu, Lianzhe; Liao, Hong; Feng, Lingyan; Wang, Min; Fu, Wensheng

    2018-04-26

    The peroxidase-like catalytic activity of gold nanoclusters (NCs) is quite low around physiological pH, which greatly limits their biological applications. Herein, we found heparin can greatly accelerate the peroxidase-like activity of Au-NCs at neutral pH. The catalytic activity of Au-NCs toward the peroxidase substrate 3,3',5,5'-tetramethylbenzidine (TMB) oxidation by H2O2 was 25-fold increased in the presence of heparin at pH 7. The addition of heparin not only accelerated the initial catalytic rate of Au-NCs, but also prevented the Au-NCs from catalyst deactivation. This allows the sensitive colorimetric detection of heparin at neutral pH. In the presence of heparinase, heparin was hydrolyzed into small fragments, weakening the enhancement effect of catalytic activity. Based on this phenomenon, the sensitive colorimetric determination of heparinase in biological samples was also developed.

  13. Targeting hepatic heparin-binding EGF-like growth factor (HB-EGF) induces anti-hyperlipidemia leading to reduction of angiotensin II-induced aneurysm development.

    Science.gov (United States)

    Kim, Seonwook; Yang, Lihua; Kim, Seongu; Lee, Richard G; Graham, Mark J; Berliner, Judith A; Lusis, Aldons J; Cai, Lei; Temel, Ryan E; Rateri, Debra L; Lee, Sangderk

    2017-01-01

    The upregulated expression of heparin binding EGF-like growth factor (HB-EGF) in the vessel and circulation is associated with risk of cardiovascular disease. In this study, we tested the effects of HB-EGF targeting using HB-EGF-specific antisense oligonucleotide (ASO) on the development of aortic aneurysm in a mouse aneurysm model. Low-density lipoprotein receptor (LDLR) deficient mice (male, 16 weeks of age) were injected with control and HB-EGF ASOs for 10 weeks. To induce aneurysm, the mice were fed a high fat diet (22% fat, 0.2% cholesterol; w/w) at 5 week point of ASO administration and infused with angiotensin II (AngII, 1,000ng/kg/min) for the last 4 weeks of ASO administration. We confirmed that the HB-EGF ASO administration significantly downregulated HB-EGF expression in multiple tissues including the liver. Importantly, the HB-EGF ASO administration significantly suppressed development of aortic aneurysms including thoracic and abdominal types. Interestingly, the HB-EGF ASO administration induced a remarkable anti-hyperlipidemic effect by suppressing very low density lipoprotein (VLDL) level in the blood. Mechanistically, the HB-EGF targeting suppressed hepatic VLDL secretion rate without changing heparin-releasable plasma triglyceride (TG) hydrolytic activity or fecal neutral cholesterol excretion rate. This result suggested that the HB-EGF targeting induced protection against aneurysm development through anti-hyperlipidemic effects. Suppression of hepatic VLDL production process appears to be a key mechanism for the anti-hyperlipidemic effects by the HB-EGF targeting.

  14. Heparin-binding epidermal growth factor-like growth factor promotes neuroblastoma differentiation.

    Science.gov (United States)

    Gaviglio, Angela L; Knelson, Erik H; Blobe, Gerard C

    2017-05-01

    High-risk neuroblastoma is characterized by undifferentiated neuroblasts and low schwannian stroma content. The tumor stroma contributes to the suppression of tumor growth by releasing soluble factors that promote neuroblast differentiation. Here we identify heparin-binding epidermal growth factor-like growth factor (HBEGF) as a potent prodifferentiating factor in neuroblastoma. HBEGF mRNA expression is decreased in human neuroblastoma tumors compared with benign tumors, with loss correlating with decreased survival. HBEGF protein is expressed only in stromal compartments of human neuroblastoma specimens, with tissue from high-stage disease containing very little stroma or HBEGF expression. In 3 human neuroblastoma cell lines (SK-N-AS, SK-N-BE2, and SH-SY5Y), soluble HBEGF is sufficient to promote neuroblast differentiation and decrease proliferation. Heparan sulfate proteoglycans and heparin derivatives further enhance HBEGF-induced differentiation by forming a complex with the epidermal growth factor receptor, leading to activation of the ERK1/2 and STAT3 pathways and up-regulation of the inhibitor of DNA binding transcription factor. These data support a role for loss of HBEGF in the neuroblastoma tumor microenvironment in neuroblastoma pathogenesis.-Gaviglio, A. L., Knelson, E. H., Blobe, G. C. Heparin-binding epidermal growth factor-like growth factor promotes neuroblastoma differentiation. © FASEB.

  15. Heparin-Induced Thrombocytopenia Associated with Massive Intracardiac Thrombosis: A Case Report

    Directory of Open Access Journals (Sweden)

    Atheer Ahmed

    2012-01-01

    Full Text Available A 60-years old patient was admitted to a community hospital with septic arthritis. He was treated with antibiotics and subcutaneous unfractionated heparin (UH was used for venous thromboprophylaxis. After three days, he developed leg deep venous thrombosis and was treated with IV heparin. One day later, the patient developed pulmonary emboli, which was found using ventilation/perfusion scan. He was transferred to the University Hospital for further management. Upon arrival, antibiotic and intravenous UH were continued. Trans-Esophageal Echocardiogram showed a thrombus in the right atrium, a small portion of which extended to the left atrium through a patent foramen ovale. Another large thrombus was noted in the right ventricle, which extended to the pulmonary artery. Review of the patient’s medical records revealed a halving of his platelet count three days following the heparin administration. Therefore, HIT seemed very likely. Intravenous UH was stopped and an emergency thrombectomy was performed. ELISA testing of HIT antibodies came negative. This made HIT diagnosis unlikely and the patient received dalteparin. A week later, as the platelet count declined again, HIT antibodies’ testing using ELISA and C-14 serotonin release was repeated, and both assays were positive. Argatroban was restarted and the platelet count normalized.

  16. Metal artifact reduction in x-ray computed tomography by using analytical DBP-type algorithm

    Science.gov (United States)

    Wang, Zhen; Kudo, Hiroyuki

    2012-03-01

    This paper investigates a common metal artifacts problem in X-ray computed tomography (CT). The artifacts in reconstructed image may render image non-diagnostic because of inaccuracy beam hardening correction from high attenuation objects, satisfactory image could not be reconstructed from projections with missing or distorted data. In traditionally analytical metal artifact reduction (MAR) method, firstly subtract the metallic object part of projection data from the original obtained projection, secondly complete the subtracted part in original projection by using various interpolating method, thirdly reconstruction from the interpolated projection by filtered back-projection (FBP) algorithm. The interpolation error occurred during the second step can make unrealistic assumptions about the missing data, leading to DC shift artifact in the reconstructed images. We proposed a differentiated back-projection (DBP) type MAR method by instead of FBP algorithm with DBP algorithm in third step. In FBP algorithm the interpolated projection will be filtered on each projection view angle before back-projection, as a result the interpolation error is propagated to whole projection. However, the property of DBP algorithm provide a chance to do filter after the back-projection in a Hilbert filter direction, as a result the interpolation error affection would be reduce and there is expectation on improving quality of reconstructed images. In other word, if we choose the DBP algorithm instead of the FBP algorithm, less contaminated projection data with interpolation error would be used in reconstruction. A simulation study was performed to evaluate the proposed method using a given phantom.

  17. Chronic intravascular coagulation associated with chronic myelocytic leukemia. Use of heparin in connection with a surgical procedure.

    Science.gov (United States)

    German, H J; Smith, J A; Lindenbaum, J

    1976-10-01

    A women with Philadelphia chromosome-positive chronic myelocytic leukemia lived nearly 12 years from the time of diagnosis. During most of this period she received no therapy, and marked cyclic oscillations in the white blood cell count were documented. The last two years of her illness were marked by a hemorrhagic disorder associated with hypofibrinogenemia, thrombocytopenia, increased plasma fibrinopeptide A concentration and markedly elevated serum levels of fibrin degradation products. The coagulation disorder was rapidly reversible on several occasions with heparin therapy. After treatment with heparin and platelet transfusions, the patient underwent successful resection of a large ovarian cyst with excellent hemostasis during the procedure. Postoperatively, the administration of heparin and platelets was discontinued and a large wound hematoma developed. After resumption of therapy with heparin and platelets, the remainder of her postoperative course was uneventful. The literature on the subject is reviewed and tentative guidelines are offered concerning the management of patients with intravascular coagulation who require diagnostic or therapeutic surgical procedures.

  18. A need for evidence-based clinical practice guidelines for the use of heparins in the elderly

    Directory of Open Access Journals (Sweden)

    Isabelle Gouin-Thibault

    2010-04-01

    Full Text Available Isabelle Gouin-Thibault1,2, Virginie Siguret1,2, Eric Pautas2,31Assistance Publique Hôpitaux de Paris, Laboratoire d’Hématologie, Hôpital Charles Foix, Paris, France; 2Université Paris Descartes, INSERM U, Paris, France; 3Assistance Publique Hôpitaux de Paris, Unité de Gériatrie Aiguë, Hôpital Charles Foix, Paris, FranceAbstract: Low-molecular-weight heparins (LMWHs have been widely studied in pivotal clinical trials or in several meta-analyses. However, the safety and optimal use of LMWHs in high-risk patients such as the very elderly remains uncertain since these patients are usually excluded from clinical trials. In terms of LMWHs in the elderly, the main concerns are renal failure and the risk of accumulation. A clinical approach consisting of a LMWH dose reduction in the elderly should be considered with great caution in terms of efficacy, since it has been tested neither in the treatment of VTE nor in VTE prophylaxis. If monitoring is considered in patients receiving therapeutic dose LMWHs, appropriate target ranges for peak anti-Xa activity levels should be used and so far, no anti-Xa activity-based guidelines have been issued. Moreover, no data support any laboratory monitoring in elderly patients treated with prophylactic dose LMWHs.Keywords: elderly patients, low-molecular-weight heparin, renal insufficiency, evidence-based medicine

  19. Gold and silver nanoparticles conjugated with heparin derivative possess anti-angiogenesis properties

    International Nuclear Information System (INIS)

    Kemp, Melissa M; Linhardt, Robert J; Kumar, Ashavani; Ajayan, Pulickel; Mousa, Shaymaa; Dyskin, Evgeny; Yalcin, Murat; Mousa, Shaker A

    2009-01-01

    Silver and gold nanoparticles display unique physical and biological properties that have been extensively studied for biological and medical applications. Typically, gold and silver nanoparticles are prepared by chemical reductants that utilize excess toxic reactants, which need to be removed for biological purposes. We utilized a clean method involving a single synthetic step to prepare metal nanoparticles for evaluating potential effects on angiogenesis modulation. These nanoparticles were prepared by reducing silver nitrate and gold chloride with diaminopyridinyl (DAP)-derivatized heparin (HP) polysaccharides. Both gold and silver nanoparticles reduced with DAPHP exhibited effective inhibition of basic fibroblast growth factor (FGF-2)-induced angiogenesis, with an enhanced anti-angiogenesis efficacy with the conjugation to DAPHP (P<0.01) as compared to glucose conjugation. These results suggest that DAPHP-reduced silver nanoparticles and gold nanoparticles have potential in pathological angiogenesis accelerated disorders such as cancer and inflammatory diseases.

  20. Gold and silver nanoparticles conjugated with heparin derivative possess anti-angiogenesis properties

    Energy Technology Data Exchange (ETDEWEB)

    Kemp, Melissa M; Linhardt, Robert J [Department of Biology, Rensselaer Polytechnic Institute, Troy, NY 12180 (United States); Kumar, Ashavani; Ajayan, Pulickel [Department of Mechanical Engineering and Materials Science, Rice University, Houston, TX 77005 (United States); Mousa, Shaymaa; Dyskin, Evgeny; Yalcin, Murat; Mousa, Shaker A, E-mail: Shaker.mousa@acphs.ed [Pharmaceutical Research Institute, Albany College of Pharmacy and Health Sciences, Albany, NY 12208 (United States)

    2009-11-11

    Silver and gold nanoparticles display unique physical and biological properties that have been extensively studied for biological and medical applications. Typically, gold and silver nanoparticles are prepared by chemical reductants that utilize excess toxic reactants, which need to be removed for biological purposes. We utilized a clean method involving a single synthetic step to prepare metal nanoparticles for evaluating potential effects on angiogenesis modulation. These nanoparticles were prepared by reducing silver nitrate and gold chloride with diaminopyridinyl (DAP)-derivatized heparin (HP) polysaccharides. Both gold and silver nanoparticles reduced with DAPHP exhibited effective inhibition of basic fibroblast growth factor (FGF-2)-induced angiogenesis, with an enhanced anti-angiogenesis efficacy with the conjugation to DAPHP (P<0.01) as compared to glucose conjugation. These results suggest that DAPHP-reduced silver nanoparticles and gold nanoparticles have potential in pathological angiogenesis accelerated disorders such as cancer and inflammatory diseases.

  1. Prolonged thromboprophylaxis with low molecular weight heparin for abdominal or pelvic surgery

    DEFF Research Database (Denmark)

    Rasmussen, Morten Schnack; Jørgensen, Lars Nannestad; Wille-Jørgensen, Peer

    2009-01-01

    BACKGROUND: Major abdominal and pelvic surgery carries a high risk of venous thromboembolism (VTE). The efficacy of thromboprophylaxis with low-molecular weight heparin (LMWH) administered during the in-hospital period is well documented, but the optimal duration of thromboprophylaxis after surgery...... evaluating prolonged thromboprophylaxis with LMWH as compared to control or placebo. 133 studies were found in the searches, of which only 4 were found eligible for inclusion, and 129 were excluded. The incidence of overall VTE after major abdominal or pelvic surgery was 14.3% (95% confidence interval 11...... significant reduction of even the incidence of symptomatic VTE from 1.7% (95% CI 0.8% - 3.4%) in the control group to 0.2 % (95% CI 0.0% - 1.2%) in patients receiving prolonged thromboprophylaxis, Peto Odds ratio 0.22 (95% CI 0.06 -0.80), P = 0.02. The respective incidence of bleeding in the control and LMWH...

  2. A Fast and High-precision Orientation Algorithm for BeiDou Based on Dimensionality Reduction

    Directory of Open Access Journals (Sweden)

    ZHAO Jiaojiao

    2015-05-01

    Full Text Available A fast and high-precision orientation algorithm for BeiDou is proposed by deeply analyzing the constellation characteristics of BeiDou and GEO satellites features.With the advantage of good east-west geometry, the baseline vector candidate values were solved by the GEO satellites observations combined with the dimensionality reduction theory at first.Then, we use the ambiguity function to judge the values in order to obtain the optical baseline vector and get the wide lane integer ambiguities. On this basis, the B1 ambiguities were solved. Finally, the high-precision orientation was estimated by the determinating B1 ambiguities. This new algorithm not only can improve the ill-condition of traditional algorithm, but also can reduce the ambiguity search region to a great extent, thus calculating the integer ambiguities in a single-epoch.The algorithm is simulated by the actual BeiDou ephemeris and the result shows that the method is efficient and fast for orientation. It is capable of very high single-epoch success rate(99.31% and accurate attitude angle (the standard deviation of pitch and heading is respectively 0.07°and 0.13°in a real time and dynamic environment.

  3. Comparison of hematologic values in blood samples with lithium heparin or dipotassium ethylenediaminetetraacetic acid anticoagulants in Hispaniolan Amazon parrots (Amazona ventralis).

    Science.gov (United States)

    Guzman, David Sanchez-Migallon; Mitchell, Mark A; Gaunt, Stephen D; Beaufrère, Hugues; Tully, Thomas N

    2008-06-01

    Blood samples were collected from 20 Hispaniolan Amazon parrots (Amazona ventralis) and were divided into tubes that contained dipotassium ethylenediaminetetraacetic acid (K2EDTA) and lithium heparin. Complete blood cell counts were determined in each sample within 2 hours of collection. The level of agreement in results was moderate for plasma protein, packed cell volume (PCV), and leukocyte, monocyte, and lymphocyte counts between the anticoagulants. Plasma protein and PCV values were significantly lower in samples with lithium heparin than in those with K2EDTA, whereas lymphocyte numbers were significantly higher in lithium heparin samples than in K2EDTA samples. The level of agreement was good for the other cell types (heterophils, eosinophils, and basophils) when comparing the different anticoagulants. The poor level of agreement between anticoagulants with the increase in thrombocyte clumping in lithium heparin samples indicates that the use of lithium heparin as anticoagulant may affect thrombocyte count. No negative effects on morphology and staining of blood cells were apparent in smears from heparin samples compared with K2EDTA samples. Within the different values compared, the limits of agreement are small enough to be confident that lithium heparin can be used for routine CBC counts in a clinical setting. The use of the same anticoagulant should be recommended to follow trends within the same patient, especially when considering plasma protein concentration, PCV, and lymphocyte count.

  4. Effect of combined topical heparin and steroid on corneal neovascularization in children.

    Science.gov (United States)

    Michels, Rike; Michels, Stephan; Kaminski, Stephan

    2012-01-01

    To demonstrate the effect of topical heparin combined with topical steroid on corneal neovascularization (CN) in children. Four children (5 eyes) with new-onset progressive CN in at least one eye received topical rimexolone or dexamethasone in combination with heparin until complete regression of CN was obtained. The regression of CN was documented by slit-lamp or anterior segment photography. All 5 eyes showed complete regression of CN within 5 months. An anti-angiogenic effect was found as early as 1 week after starting topical combination treatment. No ocular and systemic side effects were detected and treatment was well tolerated by all children. In the 3 eyes with involvement of the optical axis, symmetrical visual acuity was obtained by amblyopia treatment. Recurrence of the CN was detectable in 2 eyes at 1 and 6 months, respectively, after ending combination therapy. Both eyes responded favorably to re-treatment. Combination of topical heparin and steroid leads to rapid regression and complete inactivity of CN. This therapeutic approach is promising, especially in children with limited therapeutic alternatives and a high risk for amblyopia. Copyright 2012, SLACK Incorporated.

  5. Heparin molecularly imprinted polymer thin flm on gold electrode by plasma-induced graft polymerization for label-free biosensor.

    Science.gov (United States)

    Orihara, Kouhei; Hikichi, Atsushi; Arita, Tomohiko; Muguruma, Hitoshi; Yoshimi, Yasuo

    2018-03-20

    Heparin, a highly sulfated glycosaminoglycan, is an important biomaterial having biological and therapeutic functionalities such as anticoagulation, regeneration, and protein stabilization. This study addresses a label-free quartz crystal microbalance (QCM) biosensor for heparin detection based on a macromolecularly imprinted polymer (MIP) as an artificial recognition element. We demonstrate the novel strategy for MIP in the form of thin film on a gold (Au) electrode with the plasma-induced graft polymerization (PIP) technique. The procedure of PIP is as follows: (i) Hexamethyldisiloxane plasma-polymerized thin film (PPF) as a pre-coating scaffold of active species for PIP (post-polymerization) is deposited on an Au electrode. (ii) The PPF/Au electrode is soaked in an water solution containing heparin (template), (2-(methacryloxy)-ethyl)trimethylammonium chloride acrylamide (functional monomer), acrylamide, and N,N-methylenebisacrylamide (crosslinker). Double bonds of monomer and crosslinker attacked by residually active species in pre-coating PPF cause radical chain reaction. Consequently, a growing polymer network of 20 nm thickness of PIP-MIP thin film is formed and grafted on the PPF/Au surface. (iii) The PIP-MIP/PPF/Au is washed by sodium chloride solution so as to remove the template. Non-imprinted polymer (NIP) is carried out like the same procedure without a template. The AFM, XPS, and QCM measurements show that the PIP process facilitates macromolecularly surface imprinting of template heparin where the template is easily removed and is rapidly rebound to PIP-MIP without a diffusional barrier. The heparin-PIP-MIP specifically binds to heparin compared with heparin analog chondroitin sulfate C (selective factor: 4.0) and a detectable range of heparin in the presence of CS (0.1 wt%) was 0.001-0.1 wt%. The PIP-NIP does not show selectivity between them. The evaluated binding kinetics are association (k a  = 350 ± 100 M -1  s -1

  6. Clinical effects of low-molecular-weight heparin combined with ...

    African Journals Online (AJOL)

    Purpose: To explore the clinical effects of low-molecular-weight heparin (LMWH) combined with ulinastatin (UTI) in children with acute pancreatitis. Methods: In total, 560 patients with severe acute pancreatitis treated at Binzhou People's Hospital, Shandong, China, from April 2012 to June 2014 were enrolled in this study.

  7. Mapping the heparin-binding site of the BMP antagonist gremlin by site-directed mutagenesis based on predictive modelling.

    Science.gov (United States)

    Tatsinkam, Arnold Junior; Mulloy, Barbara; Rider, Christopher C

    2015-08-15

    Gremlin is a member of the CAN (cerberus and DAN) family of secreted BMP (bone morphogenetic protein) antagonists and also an agonist of VEGF (vascular endothelial growth factor) receptor-2. It is critical in limb skeleton and kidney development and is re-expressed during tissue fibrosis. Gremlin binds strongly to heparin and heparan sulfate and, in the present study, we sought to investigate its heparin-binding site. In order to explore a putative non-contiguous binding site predicted by computational molecular modelling, we substituted a total of 11 key arginines and lysines located in three basic residue sequence clusters with homologous sequences from cerberus and DAN (differential screening selected gene abberative in neuroblastoma), CAN proteins which lack basic residues in these positions. A panel of six Myc-tagged gremlin mutants, MGR-1-MGR-6 (MGR, mutant gremlin), each containing different combinations of targeted substitutions, all showed markedly reduced affinity for heparin as demonstrated by their NaCl elution on heparin affinity chromatography, thus verifying our predictions. Both MGR-5 and MGR-6 retained BMP-4-binding activity comparable to that of wild-type gremlin. Low-molecular-mass heparin neither promoted nor inhibited BMP-4 binding. Finally, glutaraldehyde cross-linking demonstrated that gremlin forms non-covalent dimers, similar behaviour to that of DAN and also PRDC (protein related to cerberus and DAN), another CAN protein. The resulting dimer would possess two heparin-binding sites, each running along an exposed surface on the second β-strand finger loop of one of the monomers. © 2015 Authors; published by Portland Press Limited.

  8. Early Heparin Administration Reduces Risk for Left Atrial Thrombus Formation during Atrial Fibrillation Ablation Procedures

    Directory of Open Access Journals (Sweden)

    Stefan Asbach

    2011-01-01

    Full Text Available Objective. Despite the use of anticoagulation during left atrial (LA ablation procedures, ischemic cerebrovascular accidents (CVAs are recognized as a serious complication. Heparin is usually given after safe transseptal access has been obtained, resulting in a short unprotected dwell time of catheters within the LA, which may account for CVAs. We investigated the frequency of CVAs and LA thrombus formation as detected by intracardiac ultrasound (ICE depending on the timing of heparin administration. Methods and Results. Sixty LA ablation procedures with the use of ICE were performed in 55 patients. Patients were grouped by heparin administration after (Group I, =13 and before (Group II, =47 transseptal access. Group I patients were younger (56.6±13.7 versus 65.9±9.9 years, =.01; other clinical and echocardiographic characteristics did not differ between groups. Early thrombus formation was observed in 2 (15.4% of group I patients as compared to 0% of group II patients (=.04. One CVA (2.1% occurred in one group II patient without prior thrombus detection, and none occurred in group I patients (=ns. Conclusion. Early administration of heparin reduces the risk of early intracardiac thrombus formation during LA ablation procedures. This did not result in reduced rate of CVAs.

  9. Gender-based outcomes of bivalirudin versus heparin in patients undergoing percutaneous coronary interventions: Meta-analysis of randomized controlled trials.

    Science.gov (United States)

    Mina, George S; Firouzbakht, Tina; Modi, Kalgi; Dominic, Paari

    2017-11-01

    We aimed to perform a gender-based meta-analysis of the outcome of bivalirudin versus heparin in patients undergoing percutaneous coronary interventions (PCI). Bivalirudin has been shown to decrease major bleeding when compared to heparin ± glycoprotein IIb/IIIa inhibitors (GPI) in patients undergoing PCI. It is unclear, however, if those differences in outcomes are the same for men and women. We included randomized controlled trials (RCTs) that compared bivalirudin to heparin with or without GPI in patients undergoing PCI and reported outcome data that were stratified by gender. Random effect model was used to pool odds ratio (OR) and 95% confidence intervals (CI). We included 9 trials with 33,224 patients. Bivalirudin decreased major bleeding when compared to heparin plus routine GPI in both men (OR: 0.51, P < 0.001) and women (OR: 0.55, P < 0.001). However, when GPI were used selectively with heparin, the bleeding lowering effect of bivalirudin was statistically significant in men (OR: 0.69, P = 0.02) but not in women (OR: 0.71, P = 0.21). When compared to heparin ± GPI, there was a nonstatistically significant trend toward lower all-cause mortality with bivalirudin in both men (OR: 0.76, P = 0.055) and women (OR: 0.79, P = 0.21). There were no significant differences in major adverse cardiovascular events between heparin and bivalirudin in both men and women. Bivalirudin decreases major bleeding in both men and women when compared to heparin plus routine GPI. However, when compared to heparin alone, the bleeding lowering benefit of bivalirudin is less evident in women. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  10. Biochemical and microscopic evidence for the internalization and degradation of heparin-containing mast cell granules by bovine endothelial cells

    International Nuclear Information System (INIS)

    Atkins, F.M.; Friedman, M.M.; Metcalfe, D.D.

    1985-01-01

    Incubation of [ 35 S]heparin-containing mast cell granules with cultured bovine endothelial cells was followed by the appearance of 35 S-granule-associated radioactivity within the endothelial cells and a decrease in radioactivity in the extracellular fluid. These changes occurred during the first 24 hours of incubation and suggested ingestion of the mast cell granules by the endothelial cells. Periodic electron microscopic examination of the monolayers confirmed this hypothesis by demonstrating apposition of the granules to the plasmalemma of endothelial cells, which was followed by the engulfment of the granules by cytoplasmic projections. Under light microscopic examination, mast cell granules within endothelial cells then appeared to undergo degradation. The degradation of [ 35 S]heparin in mast cell granules was demonstrated by a decrease in the amount of intracellular [ 35 S]heparin proteoglycan after 24 hours and the appearance of free [ 35 S]sulfate in the extracellular compartment. Intact endothelial cells were more efficient at degrading [ 35 S]heparin than were cell lysates or cell supernatants. These data provide evidence of the ability of endothelial cells to ingest mast cell granules and degrade native heparin that is presented as a part of the mast cell granule

  11. Heparin as a pharmacologic intervention to induce positive scintiscan in occult gastrointestinal bleeding

    International Nuclear Information System (INIS)

    Chaudhuri, T.K.; Brantly, M.

    1984-01-01

    The value of using heparin as a pharmacologic intervention to induce a positive scintiscan was studied in a patient with chronic occult gastrointestinal bleeding. When all standard diagnostic tests (upper and lower gastrointestinal series, upper and lower endoscopy, and conventional noninterventional Tc-99m RBC imaging) fail to detect and localize gastrointestinal bleeding in a patient who has definite clinical evidence (guaiac positive stool and dropping hemoglobin, hematocrit) of chronic occult gastrointestinal oozing, heparin may be used (with proper precaution) as a last resort to aid in the scintigraphic detection and localization of chronic occult gastrointestinal bleeding

  12. Successful Implantation of a Left Ventricular Assist Device in a Patient with Heparin-Induced Thrombocytopenia and Thrombosis

    Science.gov (United States)

    Garland, Cassandra; Somogyi, David

    2014-01-01

    Abstract: We report the case of a 27-year-old woman with signs of heparin-induced thrombocytopenia and thrombosis (HITT) and left heart failure presenting for urgent implantation of a left ventricular assist device (LVAD). HITT can occur in 4.2–6.1% of patients with LVADs. If the patient remains hemodynamically stable, implantation can be delayed for several months until the heparin/PF-4 antibodies decline allowing the use of heparin on cardiopulmonary bypass, However, in most cases related to cardiogenic shock, surgery cannot be delayed. We present the case of a patient who underwent implantation of a HeartMate II LVAD and discuss management strategy using bivalirudin during cardiopulmonary bypass. PMID:25208434

  13. Intravitreal low molecular weight heparin in PVR surgery.

    Directory of Open Access Journals (Sweden)

    Kumar Atul

    2003-01-01

    Full Text Available Purpose: To evaluate the efficacy of low molecular weight heparin (LMWH in prevention of postoperative fibrin formation following vitreoretinal surgery with proliferative vitreoretinopathy (PVR. Material and Methods: Thirty consecutive patients of retinal detachment with advanced PVR were enrolled in the study. They were randomised to study and control groups (n = 15 each. Study group patients received vitreoretinal surgery with 5 IU/cc of LMWH in vitrectomy infusion fluid. The control group patients received vitroretinal surgery without heparin in the infusion fluid. Patients were followed up at 1 week, 1 month and 3 months after surgery. Postoperative bleeding, media clarity, best-corrected visual acuity and success of the surgery at the end of 3 months were compared between the two groups. Results: At each follow-up visit, the study group showed a better media clarity, which was statistically significant ( P = 0.0042. The study group had a 50% better chance of retinal reattachment compared to the control group. Five patients had intraoperative bleeding in the study group (33% compared to 3 patients in the control group (20%. Conclusion: Use of intravitreal LMWH prevents postoperative fibrin formation and is beneficial in repair of retinal detachments with PVR.

  14. Deciphering the Role of Sulfonated Unit in Heparin-Mimicking Polymer to Promote Neural Differentiation of Embryonic Stem Cells.

    Science.gov (United States)

    Lei, Jiehua; Yuan, Yuqi; Lyu, Zhonglin; Wang, Mengmeng; Liu, Qi; Wang, Hongwei; Yuan, Lin; Chen, Hong

    2017-08-30

    Glycosaminoglycans (GAGs), especially heparin and heparan sulfate (HS), hold great potential for inducing the neural differentiation of embryonic stem cells (ESCs) and have brought new hope for the treatment of neurological diseases. However, the disadvantages of natural heparin/HS, such as difficulty in isolating them with a sufficient amount, highly heterogeneous structure, and the risk of immune responses, have limited their further therapeutic applications. Thus, there is a great demand for stable, controllable, and well-defined synthetic alternatives of heparin/HS with more effective biological functions. In this study, based upon a previously proposed unit-recombination strategy, several heparin-mimicking polymers were synthesized by integrating glucosamine-like 2-methacrylamido glucopyranose monomers (MAG) with three sulfonated units in different structural forms, and their effects on cell proliferation, the pluripotency, and the differentiation of ESCs were carefully studied. The results showed that all the copolymers had good cytocompatibility and displayed much better bioactivity in promoting the neural differentiation of ESCs as compared to natural heparin; copolymers with different sulfonated units exhibited different levels of promoting ability; among them, copolymer with 3-sulfopropyl acrylate (SPA) as a sulfonated unit was the most potent in promoting the neural differentiation of ESCs; the promoting effect is dependent on the molecular weight and concentration of P(MAG-co-SPA), with the highest levels occurring at the intermediate molecular weight and concentration. These results clearly demonstrated that the sulfonated unit in the copolymers played an important role in determining the promoting effect on ESCs' neural differentiation; SPA was identified as the most potent sulfonated unit for copolymer with the strongest promoting ability. The possible reason for sulfonated unit structure as a vital factor influencing the ability of the copolymers

  15. Release of proteins via ion exchange from albumin-heparin microspheres

    NARCIS (Netherlands)

    Kwon, Glen S.; Bae, You Han; Cremers, H.F.M.; Cremers, Harry; Feijen, Jan; Kim, Sung Wan

    1992-01-01

    Albumin-heparin and albumin microspheres were prepared as ion exchange gels for the controlled release of positively charged polypeptides and proteins. The adsorption isotherms of chicken egg and human lysozyme, as model proteins, on microspheres were obtained. An adsorption isotherm of chicken egg

  16. Thermodynamic parameters associated with the binding of adrenaline and norephedrine to heparin

    International Nuclear Information System (INIS)

    Ali-Ali, A.K.; Buchanan, J.D.; Power, D.M.; Butler, J.

    1983-01-01

    Pulse radiolysis was used to determine the thermodynamic parameters (ΔG', ΔH' and ΔS') governing the binding of adrenalin and norephedrine to heparin. The complexes were completely dissociated by increasing concentrations of inorganic salts. Lower concentrations of divalent cations (e.g. Ca 2+ ) were more necessary to affect dissociation than those of monovalent cations (e.g. Na + ). For each interaction, an increase in drug binding occurred as the temperature was increased from ambient. However, a transition temperature was observed (48 degC) above which the drug was progressively released as temperature was increased. These observations probably reflect conformational changes induced in the heparin below and above its melting temperature. (author)

  17. Photochemically synthesized heparin-based silver nanoparticles: an antimicrobial activity study

    Science.gov (United States)

    Rodriguez-Torres, Maria del Pilar; Acosta-Torres, Laura Susana; Díaz-Torres, Luis Armando

    2017-08-01

    The antimicrobial activity of silver nanoparticles has been extensively studied in the last years. Such nanoparticles constitute a potential and promising approach for the development of new antimicrobial systems especially due to the fact that several microorganisms are developing resistance to some already existing antimicrobial agents, therefore making antibacterial and antimicrobial studies on alternative materials necessary to overcome this issue. Silver nanoparticle concentration and size are determining factors on the antimicrobial activity of these nano systems. Heparin is a polysaccharide that belongs to the glycosaminoglycans (GAGs) family, molecules formed by a base disaccharide whose components are joined by a glycosidic linkage that is a repeating unit along their structure. It is highly sulfated making it a negatively charged material that is also widely used as an anticoagulant in Medicine because its biocompatibility besides it is also produced within the human body, specifically in the mast cells. Heparin alone possesses antimicrobial activity although it has not been studied very much in detail, it only has been demonstrated that it inhibits E. coli, P. aeruginosa, S. aureus and S. epidermidis, so taking this into account, this study is dedicated to assess UV photochemically-synthesized (λ=254 nm) heparin-based silver nanoparticles antimicrobial activity using the agar disk diffusion method complemented by the broth microdilution method to estimate de minimum inhibitory concentration (MIC), that is the lowest concentration at which an antimicrobial will inhibit visible growth of a microorganism. The strains used were the ones aforementioned to assess the antimicrobial activity degree these heparinbased nanoparticles exhibit.

  18. Heparin-mimicking multilayer coating on polymeric membrane via LbL assembly of cyclodextrin-based supramolecules.

    Science.gov (United States)

    Deng, Jie; Liu, Xinyue; Ma, Lang; Cheng, Chong; Shi, Wenbin; Nie, Chuanxiong; Zhao, Changsheng

    2014-12-10

    In this study, multifunctional and heparin-mimicking star-shaped supramolecules-deposited 3D porous multilayer films with improved biocompatibility were fabricated via a layer-by-layer (LbL) self-assembly method on polymeric membrane substrates. Star-shaped heparin-mimicking polyanions (including poly(styrenesulfonate-co-sodium acrylate; Star-PSS-AANa) and poly(styrenesulfonate-co-poly(ethylene glycol)methyl ether methacrylate; Star-PSS-EGMA)) and polycations (poly(methyl chloride-quaternized 2-(dimethylamino)ethyl methacrylate; Star-PMeDMA) were first synthesized by atom transfer radical polymerization (ATRP) from β-cyclodextrin (β-CD) based cores. Then assembly of 3D porous multilayers onto polymeric membrane surfaces was carried out by alternating deposition of the polyanions and polycations via electrostatic interaction. The surface morphology and composition, water contact angle, blood activation, and thrombotic potential as well as cell viability for the coated heparin-mimicking films were systematically investigated. The results of surface ATR-FTIR spectra and XPS spectra verified successful deposition of the star-shaped supramolecules onto the biomedical membrane surfaces; scanning electron microscopy (SEM) and atomic force microscopy (AFM) observations revealed that the modified substrate had 3D porous surface morphology, which might have a great biological influence on the biointerface. Furthermore, systematic in vitro investigation of protein adsorption, platelet adhesion, human platelet factor 4 (PF4, indicates platelet activation), activate partial thromboplastin time (APTT), thrombin time (TT), coagulation activation (thrombin-antithrombin III complex (TAT, indicates blood coagulant)), and blood-related complement activation (C3a and C5a, indicates inflammation potential) confirmed that the heparin-mimicking multilayer coated membranes exhibited ultralow blood component activations and excellent hemocompatibility. Meanwhile, after surface coating

  19. Identification of heparin samples that contain impurities or contaminants by chemometric pattern recognition analysis of proton NMR spectral data

    Energy Technology Data Exchange (ETDEWEB)

    Zang, Qingda [University of Medicine and Dentistry of New Jersey, Department of Pharmacology, Robert Wood Johnson Medical School, Piscataway, NJ (United States); Snowdon, Inc., Monmouth Junction, NJ (United States); University of Medicine and Dentistry of New Jersey, Department of Health Informatics, School of Health Related Professions, Newark, NJ (United States); Keire, David A.; Buhse, Lucinda F.; Trehy, Michael L. [Food and Drug Administration, CDER, Division of Pharmaceutical Analysis, St. Louis, MO (United States); Wood, Richard D. [Snowdon, Inc., Monmouth Junction, NJ (United States); Mital, Dinesh P.; Haque, Syed; Srinivasan, Shankar [University of Medicine and Dentistry of New Jersey, Department of Health Informatics, School of Health Related Professions, Newark, NJ (United States); Moore, Christine M.V.; Nasr, Moheb; Al-Hakim, Ali [Food and Drug Administration, CDER, Office of New Drug Quality Assessment, Silver Spring, MD (United States); Welsh, William J. [University of Medicine and Dentistry of New Jersey, Department of Pharmacology, Robert Wood Johnson Medical School, Piscataway, NJ (United States)

    2011-08-15

    Chemometric analysis of a set of one-dimensional (1D) {sup 1}H nuclear magnetic resonance (NMR) spectral data for heparin sodium active pharmaceutical ingredient (API) samples was employed to distinguish USP-grade heparin samples from those containing oversulfated chondroitin sulfate (OSCS) contaminant and/or unacceptable levels of dermatan sulfate (DS) impurity. Three chemometric pattern recognition approaches were implemented: classification and regression tree (CART), artificial neural network (ANN), and support vector machine (SVM). Heparin sodium samples from various manufacturers were analyzed in 2008 and 2009 by 1D {sup 1}H NMR, strong anion-exchange high-performance liquid chromatography, and percent galactosamine in total hexosamine tests. Based on these data, the samples were divided into three groups: Heparin, DS {<=} 1.0% and OSCS = 0%; DS, DS > 1.0% and OSCS = 0%; and OSCS, OSCS > 0% with any content of DS. Three data sets corresponding to different chemical shift regions (1.95-2.20, 3.10-5.70, and 1.95-5.70 ppm) were evaluated. While all three chemometric approaches were able to effectively model the data in the 1.95-2.20 ppm region, SVM was found to substantially outperform CART and ANN for data in the 3.10-5.70 ppm region in terms of classification success rate. A 100% prediction rate was frequently achieved for discrimination between heparin and OSCS samples. The majority of classification errors between heparin and DS involved cases where the DS content was close to the 1.0% DS borderline between the two classes. When these borderline samples were removed, nearly perfect classification results were attained. Satisfactory results were achieved when the resulting models were challenged by test samples containing blends of heparin APIs spiked with non-, partially, or fully oversulfated chondroitin sulfate A, heparan sulfate, or DS at the 1.0%, 5.0%, and 10.0% (w/w) levels. This study demonstrated that the combination of 1D {sup 1}H NMR spectroscopy

  20. Improved synthesis of polystyrene-poly(ethylene oxide)-heparin block copolymers

    NARCIS (Netherlands)

    Vulic, I.; Loman, A.J.B.; Feijen, Jan; Okano, T.; Kim, S.W.

    1990-01-01

    A novel procedure for the synthesis of block copolymers composed of a hydrophobic block of polystyrene, a hydrophilic block of poly(ethylene oxide) and a bioactive block of nitrous acid-degraded heparin was developed. Amino-semitelechelic polystyrene was prepared by anionic polymerization of styrene

  1. Intra-articular TSG-6 delivery from heparin-based microparticles reduces cartilage damage in a rat model of osteoarthritis.

    Science.gov (United States)

    Tellier, Liane E; Treviño, Elda A; Brimeyer, Alexandra L; Reece, David S; Willett, Nick J; Guldberg, Robert E; Temenoff, Johnna S

    2018-05-01

    As a potential treatment for osteoarthritis (OA), we have developed injectable and hydrolytically degradable heparin-based biomaterials with tunable sulfation for the intra-articular delivery of tumor necrosis factor-alpha stimulated gene-6 (TSG-6), a protein known to inhibit plasmin which may degrade extracellular matrix within OA joints. We first assessed the effect of heparin sulfation on TSG-6 anti-plasmin activity and found that while fully sulfated (Hep) and heparin desulfated at only the N position (Hep-N) significantly enhanced TSG-6 bioactivity in vitro, fully desulfated heparin (Hep-) had no effect, indicating that heparin sulfation plays a significant role in modulating TSG-6 bioactivity. Next, TSG-6 loaded, degradable 10 wt% Hep-N microparticles (MPs) were delivered via intra-articular injection into the knee at 1, 7, and 15 days following medial meniscal transection (MMT) injury in a rat model. After 21 days, cartilage thickness, volume, and attenuation were significantly increased with soluble TSG-6, indicating degenerative changes. In contrast, no significant differences were observed with TSG-6 loaded MP treatment, demonstrating that TSG-6 loaded MPs reduced cartilage damage following MMT injury. Ultimately, our results indicate that Hep-N can enhance TSG-6 anti-plasmin activity and that Hep-N-based biomaterials may be an effective method for TSG-6 delivery to treat OA.

  2. Heparin Assisted Photochemical Synthesis of Gold Nanoparticles and Their Performance as SERS Substrates

    Science.gov (United States)

    Rodríguez-Torres, Maria del Pilar; Díaz-Torres, Luis Armando; Romero-Servin, Sergio

    2014-01-01

    Reactive and pharmaceutical-grade heparins were used as biologically compatible reducing and stabilizing agents to photochemically synthesize colloidal gold nanoparticles. Aggregates and anisotropic shapes were obtained photochemically under UV black-light lamp irradiation (λ = 366 nm). Heparin-functionalized gold nanoparticles were characterized by Scanning Electron Microscopy and UV-Vis spectroscopy. The negatively charged colloids were used for the Surface Enhanced Raman Spectroscopy (SERS) analysis of differently charged analytes (dyes). Measurements of pH were taken to inspect how the acidity of the medium affects the colloid-analyte interaction. SERS spectra were taken by mixing the dyes and the colloidal solutions without further functionalization or addition of any aggregating agent. PMID:25342319

  3. Cyclic Voltammetry of Biopolymer Heparin at PVC Plasticized Liquid Membrane

    Czech Academy of Sciences Publication Activity Database

    Samec, Zdeněk; Trojánek, Antonín; Langmaier, Jan; Samcová, E.

    2003-01-01

    Roč. 5, - (2003), s. 867-870 ISSN 1388-2481 R&D Projects: GA ČR GA203/04/0424 Institutional research plan: CEZ:AV0Z4040901 Keywords : cyclic voltammetry * PVC plasticized liquit membrane * heparin Subject RIV: CG - Electrochemistry Impact factor: 2.300, year: 2003

  4. Heparin crisis 2008: a tipping point for increased FDA enforcement in the pharma sector?

    Science.gov (United States)

    Rosania, Larry

    2010-01-01

    Against a backdrop of steady deregulation, the pharmaceutical industry is increasingly outsourcing manufacturing, resulting in decentralized control of the global supply chain. Established products such as heparin have been held to outdated analytical standards. Ten million Americans receive heparin every year; Baxter International accounts for half of this market. In 2008, contamination of Baxter's heparin--sourced in China--resulted in about 350 adverse events and 150 deaths in the United States. In future, increasingly stringent FDA inspections and enforcement are expected for imported drugs and ingredients. More regional FDA offices will be set up overseas. FDA funding will likely be supplemented in future by user fees charged to importers. For newer products, companies will face pressure to adopt Quality by Design, with solid control of the global supply chain and a proactive focus on GMP. Older products will be held to modern standards. Long-term, imports of drugs and ingredients from developing markets will continue. This makes sense to companies from an economic standpoint, but protections will be essential to ensure that it is also justifiable from a public health perspective.

  5. Puzzle Imaging: Using Large-Scale Dimensionality Reduction Algorithms for Localization.

    Science.gov (United States)

    Glaser, Joshua I; Zamft, Bradley M; Church, George M; Kording, Konrad P

    2015-01-01

    Current high-resolution imaging techniques require an intact sample that preserves spatial relationships. We here present a novel approach, "puzzle imaging," that allows imaging a spatially scrambled sample. This technique takes many spatially disordered samples, and then pieces them back together using local properties embedded within the sample. We show that puzzle imaging can efficiently produce high-resolution images using dimensionality reduction algorithms. We demonstrate the theoretical capabilities of puzzle imaging in three biological scenarios, showing that (1) relatively precise 3-dimensional brain imaging is possible; (2) the physical structure of a neural network can often be recovered based only on the neural connectivity matrix; and (3) a chemical map could be reproduced using bacteria with chemosensitive DNA and conjugative transfer. The ability to reconstruct scrambled images promises to enable imaging based on DNA sequencing of homogenized tissue samples.

  6. Cefotaxime-heparin lock prophylaxis against hemodialysis catheter-related sepsis among Staphylococcus aureus nasal carriers

    Directory of Open Access Journals (Sweden)

    Anil K Saxena

    2012-01-01

    Full Text Available Staphylococcus aureus nasal carriers undergoing hemodialysis (HD through tunneled cuffed catheters (TCCs form a high-risk group for the development of catheter-related bloodstream infections (CRBSI and ensuing morbidity. The efficacy of antibiotic-locks on the outcomes of TCCs among S. aureus nasal carriers has not been studied earlier. Persistent nasal carriage was defined by two or more positive cultures for methicillin-susceptible (MSSA or methicillin-resistant (MRSA S. aureus of five standardized nasal swabs taken from all the participants dialyzed at a large out-patient HD center affiliated to a tertiary care hospital. Of 218 participants, 82 S. aureus nasal carriers dialyzed through TCCs (n = 88 were identified through April 2005 to March 2006 and randomized to two groups. Group I comprised of 39 nasal carriers who had TCCs (n = 41 "locked" with cefotaxime/heparin while group II included 43 patients with TCCs (n = 47 filled with standard heparin. The CRBSI incidence and TCC survival at 365 days were statistically compared between the two groups. A significantly lower CRBSI incidence (1.47 vs. 3.44/1000 catheter-days, P <0.001 and higher infection-free TCC survival rates at 365 days (80.5 vs. 40.4%, P <0.0001 were observed in the cefotaxime group compared with the stan-dard heparin group. However, no significant difference in MRSA-associated CRBSI incidence was observed between the two groups. Cefotaxime-heparin "locks" effectively reduced CRBSI-incidence associated with gram-positive cocci, including MSSA, among S. aureus nasal carriers. There remains a compelling requirement for antibiotic-locks effective against MRSA.

  7. Test and data reduction algorithm for the evaluation of lead-acid battery packs

    Energy Technology Data Exchange (ETDEWEB)

    Nowak, D.

    1986-01-15

    Experience from the DOE Electric Vehicle Demonstration Project indicated severe battery problems associated with driving electric cars in temperature extremes. The vehicle batteries suffered from a high module failure rate, reduced capacity, and low efficiency. To assess the nature and the extent of the battery problems encountered at various operating temperatures, a test program was established at the University of Alabama in Huntsville (UAH). A test facility was built that is based on Propel cycling equipment, the Hewlett Packard 3497A Data Acquisition System, and the HP85F and HP87 computers. The objective was to establish a cost effective facility that could generate the engineering data base needed for the development of thermal management systems, destratification systems, central watering systems and proper charge algorithms. It was hoped that the development and implementation of these systems by EV manufacturers and fleet operators of EVs would eliminate the most pressing problems that occurred in the DOE EV Demonstration Project. The data reduction algorithm is described.

  8. A two-domain real-time algorithm for optimal data reduction: A case study on accelerator magnet measurements

    CERN Document Server

    Arpaia, P; Inglese, V

    2010-01-01

    A real-time algorithm of data reduction, based on the combination a two lossy techniques specifically optimized for high-rate magnetic measurements in two domains (e.g. time and space), is proposed. The first technique exploits an adaptive sampling rule based on the power estimation of the flux increments in order to optimize the information to be gathered for magnetic field analysis in real time. The tracking condition is defined by the target noise level in the Nyquist band required by post-processing procedure of magnetic analysis. The second technique uses a data reduction algorithm in order to improve the compression ratio while preserving the consistency of the measured signal. The allowed loss is set equal to the random noise level in the signal in order to force the loss and the noise to cancel rather than to add, by improving the signal-to-noise ratio. Numerical analysis and experimental results of on-field performance characterization and validation for two case studies of magnetic measurement syste...

  9. Surface biomimetic modification with laminin-loaded heparin/poly-L-lysine nanoparticles for improving the biocompatibility

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Tao, E-mail: 11140021@hyit.edu.cn [Jiangsu Provincial Key Laboratory for Interventional Medical Devices, Huaiyin Institute of Technology, Huai' an (China); Hu, Youdong [Department of Geriatrics, The Affiliated Huai' an Hospital of Xuzhou Medical College, Huai' an (China); Tan, Jianying [Key Lab. of Advanced Technology for Materials of Chinese Education Ministry, School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu (China); Liu, Shihui [Jiangsu Provincial Key Laboratory for Interventional Medical Devices, Huaiyin Institute of Technology, Huai' an (China); Chen, Junying [Key Lab. of Advanced Technology for Materials of Chinese Education Ministry, School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu (China); Guo, Xin; Pan, Changjiang [Jiangsu Provincial Key Laboratory for Interventional Medical Devices, Huaiyin Institute of Technology, Huai' an (China); Li, Xia, E-mail: xial_li@qq.com [Department of Geriatrics, The Affiliated Huai' an Hospital of Xuzhou Medical College, Huai' an (China)

    2017-02-01

    Late thrombus and restenosis caused by delayed endothelialization and insufficient biocompatibility of polymer coating continue to be the greatest limitations of drug-eluting stents. In this study, based on the specific structure of vascular basement membrane, a novel biomimetic nano-coating was constructed by incorporating laminin into electrostatic-assembled heparin/poly-L-lysine nanoparticles. Alteration of heparin and poly-L-lysine concentration ratio in a certain range has no significantly influence nanoparticle size, uniformity and stability, but may affect the chemical property and subsequently the binding efficiency to dopamine-coated titanium surface. By use of this feature, four different nanoparticles were synthesized and immobilized on titanium surface for creating gradient nanoparticle binding density. According to in vitro biocompatibility evaluation, the nanoparticle modified surfaces were found to effectively block coagulation pathway and reduce thrombosis formation. Moreover, NP10L and NP15L modified surface with relatively low heparin exposing density (4.9 to 7.1 μg/cm2) showed beneficial effect in selective promoting EPCs and ECs proliferation, as well as stimulating cell migration and NO synthesis. - Highlights: • A novel laminin-loaded anticoagulant nanoparticle was prepared and used for titanium surface modification. • The nanoparticle binding density was adjustable by alteration the concentration ratio of heparin and poly-L-lysine. • In a certain range of NPs density, the surface was found to selectively direct platelet and vascular cells behavior.

  10. Surface biomimetic modification with laminin-loaded heparin/poly-L-lysine nanoparticles for improving the biocompatibility

    International Nuclear Information System (INIS)

    Liu, Tao; Hu, Youdong; Tan, Jianying; Liu, Shihui; Chen, Junying; Guo, Xin; Pan, Changjiang; Li, Xia

    2017-01-01

    Late thrombus and restenosis caused by delayed endothelialization and insufficient biocompatibility of polymer coating continue to be the greatest limitations of drug-eluting stents. In this study, based on the specific structure of vascular basement membrane, a novel biomimetic nano-coating was constructed by incorporating laminin into electrostatic-assembled heparin/poly-L-lysine nanoparticles. Alteration of heparin and poly-L-lysine concentration ratio in a certain range has no significantly influence nanoparticle size, uniformity and stability, but may affect the chemical property and subsequently the binding efficiency to dopamine-coated titanium surface. By use of this feature, four different nanoparticles were synthesized and immobilized on titanium surface for creating gradient nanoparticle binding density. According to in vitro biocompatibility evaluation, the nanoparticle modified surfaces were found to effectively block coagulation pathway and reduce thrombosis formation. Moreover, NP10L and NP15L modified surface with relatively low heparin exposing density (4.9 to 7.1 μg/cm2) showed beneficial effect in selective promoting EPCs and ECs proliferation, as well as stimulating cell migration and NO synthesis. - Highlights: • A novel laminin-loaded anticoagulant nanoparticle was prepared and used for titanium surface modification. • The nanoparticle binding density was adjustable by alteration the concentration ratio of heparin and poly-L-lysine. • In a certain range of NPs density, the surface was found to selectively direct platelet and vascular cells behavior.

  11. Voltammetric determination of heparin based on its interaction with ...

    African Journals Online (AJOL)

    ... with the linear regression equation as ∆ip″ (nA) = 360.19 C (mg/L) + 178.88 (n = 15, γ = 0.998) and the detection limit as 0.28 mg/L (3σ). The effects of coexisting substances such as metal ions, amino acids on the determination of heparin were investigated and the results showed that this method had good selectivity.

  12. Parallel Landscape Driven Data Reduction & Spatial Interpolation Algorithm for Big LiDAR Data

    Directory of Open Access Journals (Sweden)

    Rahil Sharma

    2016-06-01

    Full Text Available Airborne Light Detection and Ranging (LiDAR topographic data provide highly accurate digital terrain information, which is used widely in applications like creating flood insurance rate maps, forest and tree studies, coastal change mapping, soil and landscape classification, 3D urban modeling, river bank management, agricultural crop studies, etc. In this paper, we focus mainly on the use of LiDAR data in terrain modeling/Digital Elevation Model (DEM generation. Technological advancements in building LiDAR sensors have enabled highly accurate and highly dense LiDAR point clouds, which have made possible high resolution modeling of terrain surfaces. However, high density data result in massive data volumes, which pose computing issues. Computational time required for dissemination, processing and storage of these data is directly proportional to the volume of the data. We describe a novel technique based on the slope map of the terrain, which addresses the challenging problem in the area of spatial data analysis, of reducing this dense LiDAR data without sacrificing its accuracy. To the best of our knowledge, this is the first ever landscape-driven data reduction algorithm. We also perform an empirical study, which shows that there is no significant loss in accuracy for the DEM generated from a 52% reduced LiDAR dataset generated by our algorithm, compared to the DEM generated from an original, complete LiDAR dataset. For the accuracy of our statistical analysis, we perform Root Mean Square Error (RMSE comparing all of the grid points of the original DEM to the DEM generated by reduced data, instead of comparing a few random control points. Besides, our multi-core data reduction algorithm is highly scalable. We also describe a modified parallel Inverse Distance Weighted (IDW spatial interpolation method and show that the DEMs it generates are time-efficient and have better accuracy than the one’s generated by the traditional IDW method.

  13. The differences in heparin binding for the C-terminal basic-sequence-rich peptides of HPV-16 and HPV-18 capsid protein L1

    International Nuclear Information System (INIS)

    Sun Jian; Yu Jisheng; Yu Zhiwu; Zha Xiao; Wu Yuqing

    2012-01-01

    Graphial abstract: The differences in heparin binding for the C-terminal basic-sequence-rich peptides of HPV-16 and HPV-18 capsid protein L1. Highlights: ► Several driving forces contribute to the interaction between heparin and peptides. ► C-terminal of HPV L1 is a potential candidate for the attachment to host cells. ► The C-terminal peptides of HPV-16 and -18 L1 have different heparin-binding. ► The different heparin-binding provides an explanation for the distinct prevalences. - Abstract: The high-risk types of human papillomaviruses (HPV) HPV-16 and -18 are the predominant types associated with cervical cancer. HPV-16 and -18 account for about 50% and 20%, respectively, of cervical cancers worldwide. While the reason and molecular mechanism of the distinct prevalence and distributions between them remain poorly understood, the binding affinity of cell surface receptor with capsid proteins, especially L1, may be involved. We examined heparin binding with two synthetic peptides corresponding to the 14 amino acid C-terminal peptides of HPV-16 and -18 L1 with the goal of comparing the equivalent residues in different HPV types. Using isothermal titration calorimetry (ITC) and static right-angle light scattering (SLS), we determined the binding constant K, reaction enthalpy ΔH, and other thermodynamic parameters in the interaction. Especially, we assessed the role of specific residues in binding with heparin by comparing the NMR spectra of free and heparin-bound peptides.

  14. Determination of Oversulphated Chondroitin Sulphate and Dermatan Sulphate in unfractionated heparin by (1)H-NMR - Collaborative study for quantification and analytical determination of LoD.

    Science.gov (United States)

    McEwen, I; Mulloy, B; Hellwig, E; Kozerski, L; Beyer, T; Holzgrabe, U; Wanko, R; Spieser, J-M; Rodomonte, A

    2008-12-01

    Oversulphated Chondroitin Sulphate (OSCS) and Dermatan Sulphate (DS) in unfractionated heparins can be identified by nuclear magnetic resonance spectrometry (NMR). The limit of detection (LoD) of OSCS is 0.1% relative to the heparin content. This LoD is obtained at a signal-to-noise ratio (S/N) of 2000:1 of the heparin methyl signal. Quantification is best obtained by comparing peak heights of the OSCS and heparin methyl signals. Reproducibility of less than 10% relative standard deviation (RSD) has been obtained. The accuracy of quantification was good.

  15. Disparate effects of heparin on free thyroxine measured by two different radioimmunoassays

    International Nuclear Information System (INIS)

    McDougall, I.R.; Bayer, M.F.; Nierenberg, D.; Lewis, S.J.

    1983-01-01

    Heparin causes a rise in free thyroxine (FT4) measured by equilibrium dialysis (E.D.). With the introduction of at least 4 commercial radioimmunoassays (RIA) for FT4, FT4 measurements have become accepted as one of the best routine thyroid function tests. Investigators have indicated that FT4 levels determined by RIA may be of particular value in patients hospitalized for various severe nonthyroidal illnesses in whom conventional thyroid function tests tend to be abnormal. However, very little information is as yet available on possible effects of various drugs on FT4 levels measured by these new methods. A study was undertaken to evaluate the effect of heparin on FT4 measured by 2 different RIA procedures: RIA-I, GammaCoat FT4 by clinical Assays and RIA-II, Amerlex FT4 by Amersham

  16. Simultaneous estimation of vitamin K1 and heparin with low limit of detection using cascaded channels fiber optic surface plasmon resonance.

    Science.gov (United States)

    Tabassum, Rana; Gupta, Banshi D

    2016-12-15

    We report an approach for the simultaneous estimation of vitamin K1 (VK1) and heparin via cascaded channel multianalyte sensing probe employing fiber optic surface plasmon resonance technique. Cladding from two well separated portions of the fiber is removed and are respectively coated with thin films of silver (channel-1) and copper (channel-2). The nanohybrid of multiwalled carbon nanotube in chitosan is fabricated over silver layer for the sensing of VK1 whereas core shell nanostructure of polybrene@ZnO is coated over copper layer for the sensing of heparin. Spectral interrogation method is used for the characterization of the sensor. Analyte selectivity of both the channels is performed by carrying out experiments using independent solutions of VK1 and heparin. Experiments performed on the solution of the mixture of VK1 and heparin show red shifts in both the channels on changing the concentration of both the analytes in the mixture. The operating range of both VK1 and heparin is from 0 to 10(-3)g/l. The limit of detection of the sensor is 2.66×10(-4)µg/l and 2.88×10(-4)µg/l for VK1 and heparin respectively which are lower than the reported ones. The additional advantages of the present sensor are low cost, possibility of online monitoring and remote sensing. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. A Novel Sidelobe Reduction Algorithm Based on Two-Dimensional Sidelobe Correction Using D-SVA for Squint SAR Images

    Directory of Open Access Journals (Sweden)

    Min Liu

    2018-03-01

    Full Text Available Sidelobe reduction is a very primary task for synthetic aperture radar (SAR images. Various methods have been proposed for broadside SAR, which can suppress the sidelobes effectively while maintaining high image resolution at the same time. Alternatively, squint SAR, especially highly squint SAR, has emerged as an important tool that provides more mobility and flexibility and has become a focus of recent research studies. One of the research challenges for squint SAR is how to resolve the severe range-azimuth coupling of echo signals. Unlike broadside SAR images, the range and azimuth sidelobes of the squint SAR images no longer locate on the principal axes with high probability. Thus the spatially variant apodization (SVA filters could hardly get all the sidelobe information, and hence the sidelobe reduction process is not optimal. In this paper, we present an improved algorithm called double spatially variant apodization (D-SVA for better sidelobe suppression. Satisfactory sidelobe reduction results are achieved with the proposed algorithm by comparing the squint SAR images to the broadside SAR images. Simulation results also demonstrate the reliability and efficiency of the proposed method.

  18. Multifunctional silk-heparin biomaterials for vascular tissue engineering applications

    Science.gov (United States)

    Seib, F. Philipp; Herklotz, Manuela; Burke, Kelly A.; Maitz, Manfred F.; Werner, Carsten; Kaplan, David L.

    2013-01-01

    Over the past 30 years, silk has been proposed for numerous biomedical applications that go beyond its traditional use as a suture material. Silk sutures are well tolerated in humans, but the use of silk for vascular engineering applications still requires extensive biocompatibility testing. Some studies have indicated a need to modify silk to yield a hemocompatible surface. This study examined the potential of low molecular weight heparin as a material for refining silk properties by acting as a carrier for vascular endothelial growth factor (VEGF) and improving silk hemocompatibility. Heparinized silk showed a controlled VEGF release over 6 days; the released VEGF was bioactive and supported the growth of human endothelial cells. Silk samples were then assessed using a humanized hemocompatibility system that employs whole blood and endothelial cells. The overall thrombogenic response for silk was very low and similar to the clinical reference material polytetrafluoroethylene. Despite an initial inflammatory response to silk, apparent as complement and leukocyte activation, the endothelium was maintained in a resting, anticoagulant state. The low thrombogenic response and the ability to control VEGF release support the further development of silk for vascular applications. PMID:24099708

  19. Effect of crosslinking chemistry of albumin/heparin multilayers on FGF-2 adsorption and endothelial cell behavior

    Energy Technology Data Exchange (ETDEWEB)

    Kumorek, Marta, E-mail: kumorek@imc.cas.cz [Institute of Macromolecular Chemistry, Academy of Sciences of the Czech Republic v.v.i., Heyrovského Square 2, Prague 162 06 (Czech Republic); Janoušková, Olga, E-mail: janouskova@imc.cas.cz [Institute of Macromolecular Chemistry, Academy of Sciences of the Czech Republic v.v.i., Heyrovského Square 2, Prague 162 06 (Czech Republic); Höcherl, Anita, E-mail: hocherl@imc.cas.cz [Institute of Macromolecular Chemistry, Academy of Sciences of the Czech Republic v.v.i., Heyrovského Square 2, Prague 162 06 (Czech Republic); Houska, Milan, E-mail: houska@imc.cas.cz [Institute of Macromolecular Chemistry, Academy of Sciences of the Czech Republic v.v.i., Heyrovského Square 2, Prague 162 06 (Czech Republic); Mázl-Chánová, Eliška, E-mail: chanova@imc.cas.cz [Institute of Macromolecular Chemistry, Academy of Sciences of the Czech Republic v.v.i., Heyrovského Square 2, Prague 162 06 (Czech Republic); Kasoju, Naresh, E-mail: naresh.kasoju@eng.ox.ac.uk [Institute of Macromolecular Chemistry, Academy of Sciences of the Czech Republic v.v.i., Heyrovského Square 2, Prague 162 06 (Czech Republic); Cuchalová, Lucie, E-mail: cuchaloval@gmail.com [Institute of Macromolecular Chemistry, Academy of Sciences of the Czech Republic v.v.i., Heyrovského Square 2, Prague 162 06 (Czech Republic); and others

    2017-07-31

    Highlights: • Amine, carboxyl, and induced aldehyde groups of heparin were used for crosslinking of LbL film. • The carbodiimide-mediated cross-linking was the most efficient fixation method. • FGF-2 bound the most effectively to the glutaraldehyde-cross-linked LbL film. • Films cross-linked through carboxyl and aldehyde groups showed a slow FGF-2 release. • FGF-2-loaded LbL films stimulated the HUVECs growth better than the soluble FGF-2. - Abstract: The biomaterials that efficiently deliver growth factors represent an important challenge in cell-based tissue engineering. Layer-by-layer (LbL) thin films are attractive for incorporating controlled amounts of growth factors and releasing them over time. Herein, we investigated the effect of a method of cross-linking of albumin/heparin layer-by-layer (LbL) assembly ((Alb/Hep){sub 3}) on the loading and release of basic fibroblast growth factor (FGF-2), and subsequent proliferation of human endothelial cells (HUVECs). The (Alb/Hep){sub 3} assemblies were cross-linked using glutaraldehyde, reductive amination or carbodiimide chemistries, and then biofunctionalized with FGF-2. The (Alb/Hep){sub 3} assemblies were characterized by the infrared multi-internal reflection spectroscopy, atomic force microscopy, ellipsometry, and surface plasmon resonance (SPR). The FGF-2 loading was quantified by the SPR in situ analysis. Our results showed that the (Alb/Hep){sub 3} cross-linking affected the amount of the bound heparin (from 150 to 315 ng/cm{sup 2}), amount of FGF-2 loaded (from 75 to 125 ng/cm{sup 2}), FGF-2 release (from 15 to 53% over 8 days), and consequently the HUVEC cell proliferation (from 50 to 80 × 10{sup 3} cells/cm{sup 2} at day 5). All FGF-2 loaded assemblies stimulated the cell growth more than a soluble FGF-2 added into the cell media. In particular, the highest HUVECs proliferation was detected on the carbodiimide-cross-linked assembly. Overall, these biocompatible cross-linked assemblies can fine

  20. THE IMPACT OF HEPARIN IMPLEMENTER (GAG IN THE RABBIT INSEMINATION DOSE

    Directory of Open Access Journals (Sweden)

    Martin Fik

    2013-10-01

    Full Text Available The aim of this work was to evaluate the impact of implementer heparin in insemination dose in rabbits selected on reproductive parameters.The experiment was monitored reproductive parameters (conceptual relationship, the number of live-born pups per litter, the number of dead-born pups per litter, the number of live-born pups per inseminated does 156 does in the experimental group and 165 does in the control group. We used the ejaculate of synthetic broiler rabbit population with concentration of sperm 25-50 mil. / 0.5 ml / 1 ID. Heparin was added at a dose - 0.06 ml = 10 mg per 0.5 ml semen / 1 ID. Assessing selected reproductive parameters in does inseminated with insemination dose with the addition of heparin, we observed a higher conceptual proportion of 14.12 % in the experimental group compared to the control group. These differences did not show a statistically significant difference (χ 2 3.56-. The number of live-born pups per litter was 8.69 ± 4.10 pc in the experimental group and 8.41 ± 3.62 pc in the control group (P> 0.05. The number of dead-born pups was recorded 0.74 pc in the experimental group and 0.76 pc in the control group (P> 0.05. The number of live-born pups per litter per inseminated does we have seen improvement in favor of experimental group by 1.39 pc. This parameter was within each of experiments ranged from 0.91 to 1.66 pc live-born pups to inseminated does.

  1. Prediction of the oversulphated chondroitin sulphate contamination of unfractionated heparin by ATR-IR spectrophotometry.

    Science.gov (United States)

    Norwig, J; Beyer, T; Brinz, D; Holzgrabe, U; Diller, M; Manns, D

    2009-03-01

    The detection of a contamination of heparin with oversulphated chondroitin sulphate (OSCS) was first analysed in an unfractionated heparin batch supplied to the US API-market in April 2006. OSCS is a semi-synthetic derivative of the natural occuring glycosaminoglycan chondroitin sulphate. Moreover some spectroscopic characteristics of the substance overlap with those of heparin, so that the infrared (IR) spectra are visually difficult to distinguish whereas (1)H-NMR (Nuclear Magnetic Resonance) spectroscopy or capillary electrophoresis (CE) provides identification by a simple visual inspection of either the spectrum or the electropherogram respectively. However, applying special tools of Multivariate Data Analysis (MVA) to the IR spectra an identification of the contaminated samples is possible. In detail a rapid Attenuation Total Reflectance-Infrared (ATR-IR) measurement was selected, which does not require any sample preparation. The result (contaminated or not contaminated) is predicted within a few minutes. A method transfer to mobile ATR-IR spectrometers seems to be possible. The analysis is based on the fact that the fingerprint of the OSCS IR spectrum (1st derivative) complies with a theoretically calculated principal component in the MVA.

  2. Improved patency and reduced intimal hyperplasia in PTFE grafts with luminal immobilized heparin compared with standard PTFE grafts at six months in a sheep model.

    Science.gov (United States)

    Pedersen, G; Laxdal, E; Ellensen, V; Jonung, T; Mattsson, E

    2010-06-01

    The aim of this study was to compare the performance of polytetrafluoroethylene (PTFE) grafts with luminal coating of immobilized heparin to that of standard PTFE grafts at six months. Twenty-eight common carotid arteries in fourteen sheep were bypassed with heparin-coated PTFE grafts (6 mm diameter, 6 cm length) on one side and standard PTFE grafts on the other. The grafts were explanted after six months. The thickness of intimal hyperplasia (IH) in open grafts was measured with histomorphometrical methods. Two of 14 heparinized PTFE grafts and nine of 14 grafts in the control PTFE-group were occluded at explantation (P=0.006). Six-month patency rates for heparinized PTFE grafts and for standard PTFE grafts were 86% and 36%, respectively. Mean graft anastomotic IH thickness in open grafts were 0.074 mm for heparinized PTFE grafts and 0.259 mm for PTFE-grafts (P=0.006). PTFE grafts with luminal coating containing immobilized heparin had significantly better patency and recruited less intimal hyperplasia than standard PTFE grafts at six months.

  3. A triad of lys12, lys41, arg78 spatial domain, a novel identified heparin binding site on tat protein, facilitates tat-driven cell adhesion.

    Directory of Open Access Journals (Sweden)

    Jing Ai

    Full Text Available Tat protein, released by HIV-infected cells, has a battery of important biological effects leading to distinct AIDS-associated pathologies. Cell surface heparan sulfate protoglycans (HSPGs have been accepted as endogenous Tat receptors, and the Tat basic domain has been identified as the heparin binding site. However, findings that deletion or substitution of the basic domain inhibits but does not completely eliminate Tat-heparin interactions suggest that the basic domain is not the sole Tat heparin binding site. In the current study, an approach integrating computational modeling, mutagenesis, biophysical and cell-based assays was used to elucidate a novel, high affinity heparin-binding site: a Lys12, Lys41, Arg78 (KKR spatial domain. This domain was also found to facilitate Tat-driven β1 integrin activation, producing subsequent SLK cell adhesion in an HSPG-dependent manner, but was not involved in Tat internalization. The identification of this new heparin binding site may foster further insight into the nature of Tat-heparin interactions and subsequent biological functions, facilitating the rational design of new therapeutics against Tat-mediated pathological events.

  4. Finding optimal exact reducts

    KAUST Repository

    AbouEisha, Hassan M.

    2014-01-01

    The problem of attribute reduction is an important problem related to feature selection and knowledge discovery. The problem of finding reducts with minimum cardinality is NP-hard. This paper suggests a new algorithm for finding exact reducts with minimum cardinality. This algorithm transforms the initial table to a decision table of a special kind, apply a set of simplification steps to this table, and use a dynamic programming algorithm to finish the construction of an optimal reduct. I present results of computer experiments for a collection of decision tables from UCIML Repository. For many of the experimented tables, the simplification steps solved the problem.

  5. Comparison of Algorithms for the Optimal Location of Control Valves for Leakage Reduction in WDNs

    Directory of Open Access Journals (Sweden)

    Enrico Creaco

    2018-04-01

    Full Text Available The paper presents the comparison of two different algorithms for the optimal location of control valves for leakage reduction in water distribution networks (WDNs. The former is based on the sequential addition (SA of control valves. At the generic step Nval of SA, the search for the optimal combination of Nval valves is carried out, while containing the optimal combination of Nval − 1 valves found at the previous step. Therefore, only one new valve location is searched for at each step of SA, among all the remaining available locations. The latter algorithm consists of a multi-objective genetic algorithm (GA, in which valve locations are encoded inside individual genes. For the sake of consistency, the same embedded algorithm, based on iterated linear programming (LP, was used inside SA and GA, to search for the optimal valve settings at various time slots in the day. The results of applications to two WDNs show that SA and GA yield identical results for small values of Nval. When this number grows, the limitations of SA, related to its reduced exploration of the research space, emerge. In fact, for higher values of Nval, SA tends to produce less beneficial valve locations in terms of leakage abatement. However, the smaller computation time of SA may make this algorithm preferable in the case of large WDNs, for which the application of GA would be overly burdensome.

  6. Mapping of low molecular weight heparins using reversed phase ion pair liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Li, Daoyuan; Chi, Lequan; Jin, Lan; Xu, Xiaohui; Du, Xuzhao; Ji, Shengli; Chi, Lianli

    2014-01-01

    Low molecular weight heparins (LMWHs) are structurally complex, highly sulfated and negatively charged, linear carbohydrate polymers prepared by chemical or enzymatic depolymerization of heparin. They are widely used as anticoagulant drugs possessing better bioavailability, longer half-life, and lower side effects than heparin. Comprehensive structure characterization of LMWHs is important for drug quality assurance, generic drug application, and new drug research and development. However, fully characterization of all oligosaccharide chains in LMWHs is not feasible for current available analytical technologies due to their structure complexity and heterogeneity. Fingerprinting profiling is an efficient way for LMWHs' characterization and comparison. In this work, we present a simple, sensitive, and powerful analytical approach for structural characterization of LMWHs. Two different LMWHs, enoxaparin and nadroparin, were analyzed using reversed phase ion pair electrospray ionization mass spectrometry (RPIP-ESI-MS). More than 200 components were identified, including major structures, minor structures, and process related impurities. This approach is robust for high resolution and complementary fingerprinting analysis of LMWHs. Copyright © 2013 Elsevier Ltd. All rights reserved.

  7. Prototype metal artefact reduction algorithm in flat panel computed tomography - evaluation in patients undergoing transarterial hepatic radioembolisation

    International Nuclear Information System (INIS)

    Hamie, Qeumars Mustafa; Kobe, Adrian Raoul; Mietzsch, Leif; Puippe, Gilbert Dominique; Pfammatter, Thomas; Guggenberger, Roman; Manhart, Michael

    2018-01-01

    To investigate the effect of an on-site prototype metal artefact reduction (MAR) algorithm in cone-beam CT-catheter-arteriography (CBCT-CA) in patients undergoing transarterial radioembolisation (RE) of hepatic masses. Ethical board approved retrospective study of 29 patients (mean 63.7±13.7 years, 11 female), including 16 patients with arterial metallic coils, undergoing CBCT-CA (8s scan, 200 degrees rotation, 397 projections). Image reconstructions with and without prototype MAR algorithm were evaluated quantitatively (streak-artefact attenuation changes) and qualitatively (visibility of hepatic parenchyma and vessels) in near- (<1cm) and far-field (>3cm) of artefact sources (metallic coils and catheters). Quantitative and qualitative measurements of uncorrected and MAR corrected images and different artefact sources were compared Quantitative evaluation showed significant reduction of near- and far-field streak-artefacts with MAR for both artefact sources (p<0.001), while remaining stable for unaffected organs (all p>0.05). Inhomogeneities of attenuation values were significantly higher for metallic coils compared to catheters (p<0.001) and decreased significantly for both after MAR (p<0.001). Qualitative image scores were significantly improved after MAR (all p<0.003) with by trend higher artefact degrees for metallic coils compared to catheters. In patients undergoing CBCT-CA for transarterial RE, prototype MAR algorithm improves image quality in proximity of metallic coil and catheter artefacts. (orig.)

  8. Prototype metal artefact reduction algorithm in flat panel computed tomography - evaluation in patients undergoing transarterial hepatic radioembolisation

    Energy Technology Data Exchange (ETDEWEB)

    Hamie, Qeumars Mustafa; Kobe, Adrian Raoul; Mietzsch, Leif; Puippe, Gilbert Dominique; Pfammatter, Thomas; Guggenberger, Roman [University Hospital Zurich, Department of Radiology, Zurich (Switzerland); Manhart, Michael [Imaging Concepts, HC AT IN IMC, Siemens Healthcare GmbH, Advanced Therapies, Innovation, Forchheim (Germany)

    2018-01-15

    To investigate the effect of an on-site prototype metal artefact reduction (MAR) algorithm in cone-beam CT-catheter-arteriography (CBCT-CA) in patients undergoing transarterial radioembolisation (RE) of hepatic masses. Ethical board approved retrospective study of 29 patients (mean 63.7±13.7 years, 11 female), including 16 patients with arterial metallic coils, undergoing CBCT-CA (8s scan, 200 degrees rotation, 397 projections). Image reconstructions with and without prototype MAR algorithm were evaluated quantitatively (streak-artefact attenuation changes) and qualitatively (visibility of hepatic parenchyma and vessels) in near- (<1cm) and far-field (>3cm) of artefact sources (metallic coils and catheters). Quantitative and qualitative measurements of uncorrected and MAR corrected images and different artefact sources were compared Quantitative evaluation showed significant reduction of near- and far-field streak-artefacts with MAR for both artefact sources (p<0.001), while remaining stable for unaffected organs (all p>0.05). Inhomogeneities of attenuation values were significantly higher for metallic coils compared to catheters (p<0.001) and decreased significantly for both after MAR (p<0.001). Qualitative image scores were significantly improved after MAR (all p<0.003) with by trend higher artefact degrees for metallic coils compared to catheters. In patients undergoing CBCT-CA for transarterial RE, prototype MAR algorithm improves image quality in proximity of metallic coil and catheter artefacts. (orig.)

  9. Endothelial cell capture of heparin-binding growth factors under flow.

    Directory of Open Access Journals (Sweden)

    Bing Zhao

    2010-10-01

    Full Text Available Circulation is an important delivery method for both natural and synthetic molecules, but microenvironment interactions, regulated by endothelial cells and critical to the molecule's fate, are difficult to interpret using traditional approaches. In this work, we analyzed and predicted growth factor capture under flow using computer modeling and a three-dimensional experimental approach that includes pertinent circulation characteristics such as pulsatile flow, competing binding interactions, and limited bioavailability. An understanding of the controlling features of this process was desired. The experimental module consisted of a bioreactor with synthetic endothelial-lined hollow fibers under flow. The physical design of the system was incorporated into the model parameters. The heparin-binding growth factor fibroblast growth factor-2 (FGF-2 was used for both the experiments and simulations. Our computational model was composed of three parts: (1 media flow equations, (2 mass transport equations and (3 cell surface reaction equations. The model is based on the flow and reactions within a single hollow fiber and was scaled linearly by the total number of fibers for comparison with experimental results. Our model predicted, and experiments confirmed, that removal of heparan sulfate (HS from the system would result in a dramatic loss of binding by heparin-binding proteins, but not by proteins that do not bind heparin. The model further predicted a significant loss of bound protein at flow rates only slightly higher than average capillary flow rates, corroborated experimentally, suggesting that the probability of capture in a single pass at high flow rates is extremely low. Several other key parameters were investigated with the coupling between receptors and proteoglycans shown to have a critical impact on successful capture. The combined system offers opportunities to examine circulation capture in a straightforward quantitative manner that

  10. Comparison of two doses of heparin on outcome in off-pump coronary artery bypass surgery patients: A prospective randomized control study

    Directory of Open Access Journals (Sweden)

    Murali Chakravarthy

    2017-01-01

    Full Text Available Introduction: While off pump coronary artery bypass surgery is practiced with an intention to reduce the morbidity associated with cardiopulmonary bypass, the resultant ′hypercoagulability′ needs to be addressed. Complications such as cavitary thrombus possibly due to the hyper coagulability after off pump coronary artery bypass surgery have been described. Many clinicians use higher doses of heparin - up to 5 mg/kg in order to thwart this fear. Overall, there appears to be no consensus on the dose of heparin in off pump coronary artery bypass surgeries. Aim of the Study: The aim of the study was understand the differences in outcome of such as transfusion requirement, myocardial ischemia, and morbidity when two different doses were used for systemic heparinization. Methods: Elective patients scheduled for off pump coronary artery bypass surgery were included. Ongoing anti platelet medication was not an exclusion criteria, however, anti platelet medications were ceased about a week prior to surgery when possible. Thoracic epidural anesthesia was administered as an adjunct in patients who qualified for it. By computer generated randomization chart, patients were chosen to receive either 2 or 3 mg/kg of intravenous unfractioned heparin to achieve systemic heparinization with activated clotting time targeted at >240 secs. Intraoperative blood loss, postoperative blood loss, myocardial ischemic episodes, requirement of intraaortic balloon counter pulsation and transfusion requirement were analyzed. Results: Sixty two patients participated in the study. There was one conversion to cardiopulmonary bypass. The groups had comparable ACT at baseline (138.8 vs. 146.64 seconds, P = 0.12; 3 mg/kg group had significantly higher values after heparin, as expected. But after reversal with protamine, ACT and need for additional protamine was similar among the groups. Intraoperative (685.56 ± 241.42 ml vs. 675.15 ± 251.86 ml, P = 0.82 and postoperative

  11. Subcutis calcinosis caused by injection of calcium-containing heparin in a chronic kidney injury patient

    Directory of Open Access Journals (Sweden)

    Lilia Ben Fatma

    2014-01-01

    Full Text Available Subcutis calcinosis, characterized by abnormal calcium deposits in the skin, is a rare complication of using calcium-containing heparin occurring in patients with advanced renal failure. We report the case of an 83-year-old female, a known case of chronic kidney disease (CKD for four years with recent worsening of renal failure requiring hospitalization and hemodialysis. She developed subcutis calcinosis following injection of calcium-containing heparin. Biochemical tests showed serum parathormone level at 400 pg/dL, hypercalcemia, elevated calcium-phosphate product and monoclonal gammopathy related to multiple myeloma. She developed firm subcu-taneous nodules in the abdomen and the thighs, the injection sites of Calciparin ® (calcium nadroparin that was given as a preventive measure against deep vein thrombosis. The diagnosis of subcutis calcinosis was confirmed by the histological examination showing calcium deposit in the dermis and hypodermis. These lesions completely disappeared after discontinuing calcium nadro-parin injections. Subcutis calcinosis caused by injections of calcium-containing heparin is rare, and, to the best our knowledge, not more than 12 cases have been reported in the literature. Pathogenesis is not well established but is attributed to the calcium disorders usually seen in advanced renal failure. Diagnosis is confirmed by histological tests. Outcome is mostly favorable. The main differential diagnosis is calciphylaxis, which has a poor prognosis. Even though rarely reported, we should be aware that CKD patients with elevated calcium-phosphorus product can develop subcutis calcinosis induced by calcium-containing heparin. When it occurs, fortunately and unlike calci-phylaxis, outcome is favorable.

  12. Polyguluronate sulfate and its oligosaccharides but not heparin promotes FGF19/FGFR1c signaling

    Science.gov (United States)

    Lan, Ying; Zeng, Xuan; Guo, Zhihua; Zeng, Pengjiao; Hao, Cui; Zhao, Xia; Yu, Guangli; Zhang, Lijuan

    2017-06-01

    Fibroblast growth factor 19(FGF19) functions as a hormone by affecting glucose metabolism. FGF19 improves glucose tolerance when overexpressed in mice with impaired glucose tolerance or diabetes. A functional cellular FGF19 receptor consists of FGF receptor (FGFR) and glycosaminoglycan complexed with either α Klotho or β Klotho. Interestingly, in mice with diet-induced diabetes, a single injection of FGF1 is enough to restore blood sugar levels to a healthy range. FGF1 binds heparin with high affinity whereas FGF19 does not, indicating that polysaccharides other than heparin might enhance FGF19/FGFR signaling. Using a FGFs/FGFR1c signaling-dependent BaF3 cell proliferation assay, we discovered that polyguluronate sulfate (PGS) and its oligosaccharides, PGS12 and PGS25, but not polyguluronate (PG), a natural marine polysaccharide, enhanced FGF19/FGFR1c signaling better than that of heparin based on 3H-thymidine incorporation. Interestingly, PGS6, PGS8, PGS10, PGS12, PGS25, and PGS, but not PG, had comparable FGF1/FGFR1c signal-stimulating activity compared to that of heparin. These results indicated that PGS and its oligosaccharides were excellent FGF1/FGFR1c and FGF19/FGFR1c signaling enhancers at cellular level. Since the inexpensive PGS and PGS oligosaccharides can be absorbed through oral route, these seaweed-derived compounds merit further investigation as novel agents for the treatment of type 2 diabetes through enhancing FGF1/FGFR1c and FGF19/FGFR1c signaling in future.

  13. Development and in vivo evaluation of an oral delivery system for low molecular weight heparin based on thiolated polycarbophil.

    Science.gov (United States)

    Kast, Constantia E; Guggi, Davide; Langoth, Nina; Bernkop-Schnürch, Andreas

    2003-06-01

    It was the purpose of this study to develop a new oral drug delivery system for low molecular weight heparin (LMWH) providing an improved bioavailability and a prolonged therapeutic effect. The permeation enhancing polycarbophil-cysteine conjugate (PCP-Cys) used in this study displayed 111.4 +/- 6.4 microM thiol groups per gram polymer. Permeation studies on freshly excised intestinal mucosa were performed in Ussing chambers demonstrating a 2-fold improved uptake of heparin as a result of the addition of 0.5% (w/v) PCP-Cys and the permeation mediator glutathione (GSH). Tablets containing PCP-Cys, GSH, and 279 IU of LMWH showed a sustained drug release over 4 h. To guarantee the swelling of the polymeric carrier matrix in the small intestine tablets were enteric coated. They were orally given to rats. For tablets being based on the thiomer/GSH system an absolute bioavailability of 19.9 +/- 9.3% (means +/- SD; n = 5) vs. intravenous injection could be achieved. whereas tablets comprising unmodified PCP did not lead to a significant (p < 0.01) heparin concentration in plasma. The permeation enhancing effect and subsequently a therapeutic heparin level was maintained for 24 h after a single dose. Because of the strong and prolonged lasting permeation enhancing effect of the thiomer/GSH system, the oral bioavailability of LMWH could be significantly improved. This new delivery system represents therefore a promising tool for the oral administration of heparin.

  14. Comparison on Anticoagulation and Antiplatelet Aggregation Effects of Puerarin with Heparin Sodium and Tirofiban Hydrochloride: An In Vitro Study.

    Science.gov (United States)

    Li, Si-Wei; Feng, Xue; Xu, Hao; Chen, Ke-Ji

    2018-02-01

    To detect the anticoagulation and antiplatelet effects of different concentrations of puerarin, heparin sodium and tirofiban hydrochloride on the blood samples of healthy volunteers by Sonoclot coagulation and platelet function analyzer. Peripheral blood samples were extracted from 20 healthy volunteers, followed by adding different concentrations of puerarin, heparin sodium and tirofiban hydrochloride. Samples were detected for activated clotting time (ACT), clot rate (CR) and platelet function (PF) by Sonoclot coagulation and platelet function analyzer instrument. For puerarin and heparin sodium, the values of ACT gradually increased, and the values of CR and PF gradually decreased with increasing in drug concentration. There was a linear (or log linear) relationship between ACT, CR, PF value and drug concentration (Phydrochloride, the values of ACT and CR had no significant changes, while PF values gradually decreased with concentration increasing. There was also a linear relationship between PF values and concentrations of tirofiban hydrochloride (Psodium. For high concentrations of puerarin (e.g. 3.8 mg/600 μL) and tirofiban hydrochloride (e.g. 0.8 μg/600 μL), PF values had no significant difference. However, PF values for high puerarin concentration had a larger variance. Puerarin has similar anticoagulant and antiplatelet effects with the heparin sodium, and may have a lower hemorrhage risk than heparin sodium when obtained the same anticoagulation effect in the concentration range of this experiment. In addition, for high concentration, puerarin had the same antiplatelet function as tirofiban hydrochloride but with a larger individual variability.

  15. Synthesis and characterization of polystyrene-poly(ethylene oxide)-heparin block copolymers

    NARCIS (Netherlands)

    Vulić, I.; Okano, T.; Kim, S.W.; Feijen, Jan

    1988-01-01

    A procedure for the preparation of new block copolymers composed of a hydrophobic block of polystyrene, a hydrophilic spacer-block of poly(ethylene oxide) and a bioactive block of heparin was investigated. Polystyrene with one amino group per chain was synthesized by free radical oligomerization of

  16. Capillary electrophoresis of heparin and other glycosaminoglycans using a polyamine running electrolyte

    Energy Technology Data Exchange (ETDEWEB)

    Loegel, Thomas N.; Trombley, John D.; Taylor, Richard T. [Department of Chemistry and Biochemistry, Miami University, Oxford, OH 45056 (United States); Danielson, Neil D., E-mail: danielnd@muohio.edu [Department of Chemistry and Biochemistry, Miami University, Oxford, OH 45056 (United States)

    2012-11-13

    Highlights: Black-Right-Pointing-Pointer Ethylenediamine is likely acting as an ion-pairing agent. Black-Right-Pointing-Pointer Oversulfated chondroitin sulfate is last peak instead of first peak. Black-Right-Pointing-Pointer There is about a factor of five improved detectability with a 12.5 min analysis time. Black-Right-Pointing-Pointer Use of a 50 {mu}m ID capillary is possible. - Abstract: This study involves the use of polyamines as potential resolving agents for the capillary electrophoresis (CE) of glycosaminoglycans (GAGs), specifically heparin, dermatan sulfate, chondroitin sulfate, over-sulfated chondroitin sulfate (OSCS), and hyaluronan. All of the compounds can be separated from each other with the exception of chondroitin sulfate and hyaluronan. Using optimization software, the final run conditions are found to be 200 mM ethylenediamine and 45.5 mM phosphate as the electrolyte with -14 V applied across a 50 {mu}m ID Multiplication-Sign 24.5 cm fused silica capillary at 15 Degree-Sign C. The ion migration order, with OSCS as the last instead of the first peak, is in contrast to previous reports using either a high molarity TRIS or lithium phosphate run buffer with narrower bore capillaries. Total analysis time is 12. 5 min and the relative standard deviation of the heparin migration time is about 2.5% (n = 5). The interaction mechanism between selected polyamines and heparin is explored using conductivity measurements in addition to CE experiments to show that an ion-pairing mechanism is likely.

  17. Capillary electrophoresis of heparin and other glycosaminoglycans using a polyamine running electrolyte

    International Nuclear Information System (INIS)

    Loegel, Thomas N.; Trombley, John D.; Taylor, Richard T.; Danielson, Neil D.

    2012-01-01

    Highlights: ► Ethylenediamine is likely acting as an ion-pairing agent. ► Oversulfated chondroitin sulfate is last peak instead of first peak. ► There is about a factor of five improved detectability with a 12.5 min analysis time. ► Use of a 50 μm ID capillary is possible. - Abstract: This study involves the use of polyamines as potential resolving agents for the capillary electrophoresis (CE) of glycosaminoglycans (GAGs), specifically heparin, dermatan sulfate, chondroitin sulfate, over-sulfated chondroitin sulfate (OSCS), and hyaluronan. All of the compounds can be separated from each other with the exception of chondroitin sulfate and hyaluronan. Using optimization software, the final run conditions are found to be 200 mM ethylenediamine and 45.5 mM phosphate as the electrolyte with −14 V applied across a 50 μm ID × 24.5 cm fused silica capillary at 15 °C. The ion migration order, with OSCS as the last instead of the first peak, is in contrast to previous reports using either a high molarity TRIS or lithium phosphate run buffer with narrower bore capillaries. Total analysis time is 12. 5 min and the relative standard deviation of the heparin migration time is about 2.5% (n = 5). The interaction mechanism between selected polyamines and heparin is explored using conductivity measurements in addition to CE experiments to show that an ion-pairing mechanism is likely.

  18. Heparin surface stent-graft for the treatment of a carotid pseudoaneurysm.

    Science.gov (United States)

    Tsolaki, Elpiniki; Elpiniki, Tsolaki; Salviato, Elisabetta; Rocca, Tiberio; Braccini, Lucia; Galeotti, Roberto; Mascoli, Francesco

    2010-10-01

    Carotid pseudoaneurysms are a rare consequence of carotid surgery, trauma, and infection. Historically, carotid aneurysms and pseudoaneurysms were treated surgically. However, endovascular techniques have recently become a valid alternative for the treatment of carotid pseudoaneurysms. The case of a 57-year-old male patient with a pseudoaneurysm of the right internal carotid artery is described. The patient came to our unit with a painless and pulsatile mass in the neck, which was growing slowly. Five years earlier, he had undergone surgery on a saccular aneurysm located on the distal extracranial segment of the right internal carotid artery. The pseudoaneurysm was successfully treated with a heparin surface Viabahn stent-graft system (Gore AL, Flagstaff, AZ). Heparin surface stent-grafts can be used for the treatment of carotid lesions and may offer protection against intimal hyperplasia and thrombosis. Further studies are needed to evaluate the long-term results. Copyright © 2010 Annals of Vascular Surgery Inc. Published by Elsevier Inc. All rights reserved.

  19. Heparin binding sites on Ross River virus revealed by electron cryo-microscopy

    International Nuclear Information System (INIS)

    Zhang Wei; Heil, Marintha; Kuhn, Richard J.; Baker, Timothy S.

    2005-01-01

    Cell surface glycosaminoglycans play important roles in cell adhesion and viral entry. Laboratory strains of two alphaviruses, Sindbis and Semliki Forest virus, have been shown to utilize heparan sulfate as an attachment receptor, whereas Ross River virus (RRV) does not significantly interact with it. However, a single amino acid substitution at residue 218 in the RRV E2 glycoprotein adapts the virus to heparan sulfate binding and expands the host range of the virus into chicken embryo fibroblasts. Structures of the RRV mutant, E2 N218R, and its complex with heparin were determined through the use of electron cryo-microscopy and image reconstruction methods. Heparin was found to bind at the distal end of the RRV spikes, in a region of the E2 glycoprotein that has been previously implicated in cell-receptor recognition and antibody binding

  20. Comparison of heparinized saline and 0.9% sodium chloride for maintaining peripheral intravenous catheter patency in dogs.

    Science.gov (United States)

    Ueda, Yu; Odunayo, Adesola; Mann, F A

    2013-01-01

    To determine whether heparinized saline would be more effective in maintaining the patency of peripheral IV catheters in dogs compared to 0.9% sodium chloride. Prospective blinded randomized study. University Veterinary Teaching Hospital. Thirty healthy purpose bred dogs, intended for use in the junior surgery laboratory, were utilized. The dogs were randomized into 1 of 3 groups, 2 treatment groups and a control group. An 18-Ga cephalic catheter was placed in the cephalic vein of each dog. Each dog in the treatment group had their catheter flushed with either 10 IU/mL heparinized saline or 0.9% sodium chloride every 6 hours for 42 hours. The dogs in the control group did not have their catheters flushed until the end of the study period. Immediately prior to flushing catheters, each catheter was evaluated for patency by aspiration of blood and the catheter site was evaluated for phlebitis. All dogs in the heparinized saline and 0.9% sodium chloride group had catheters that flushed easily at each evaluation point. More dogs in the saline group had catheters from which blood could not be aspirated, but there was no significant difference between these groups. All dogs in the control group had catheters that flushed easily at the end of the assigned 6 hour interval except in 1 dog. Phlebitis was not detected in any dog. Flushes of 0.9% sodium chloride were found to be as effective as 10 IU/mL heparinized saline flushes in maintaining patency of 18-Ga peripheral venous catheters in dogs for up to 42 hours. For peripheral catheters placed with the intention of performing serial blood draws, heparinized flushes may be warranted. © Veterinary Emergency and Critical Care Society 2013.

  1. Nuclear androgen receptors in human prostatic tissue. Extraction with heparin and estimation of the number of binding sites with different methods

    International Nuclear Information System (INIS)

    Foekens, J.A.; Bolt-de Vries, J.; Mulder, E.; Blankenstein, M.A.; Schroeder, F.H.; Molen, H.J. van der

    1981-01-01

    A procedure for the estimation of nuclear androgen receptors in benign prostatic hyperplastic tissue is described, which employs extraction of receptors from nuclei with buffers containing heparin. Extraction of a nuclear pellet with a heparin-containing (1 g/l) buffer appeared to have definite advantages over 0.4 mol/l KCl extraction. Heparin appeared to be twice as efficient in extracting androgen receptors. In addition aggregated receptor proteins, formed after storage at -80 0 C, were partly deaggregated by heparin. Specific isolation of the androgen receptor was performed using either agar gel electrophoresis, protamine sulphate precipitation or LH-20 gel filtration. A comparison was made between the amounts of estimated receptors with these different techniques. Protamine sulphate precipitation resulted in the highest estimates of receptor-bound 5α-[ 3 H]dihydrotestosterone ( 3 H-DHT). Treatment of the labelled nuclear extracts with a charcoal suspension prior to the receptor assay resulted in lower amounts of estimated androgen receptors. A method for routine evaluation of nuclear androgen receptors in prostatic tissue has been evaluated, which involves extraction of nuclear pellets with a heparin-containing (1 g/l) buffer, exchange labelling of the nuclear extracts for 20 h at 10 0 C and quantification of the receptors with protamine sulphate precipitation. (Auth.)

  2. Genetic Algorithm-Guided, Adaptive Model Order Reduction of Flexible Aircrafts

    Science.gov (United States)

    Zhu, Jin; Wang, Yi; Pant, Kapil; Suh, Peter; Brenner, Martin J.

    2017-01-01

    This paper presents a methodology for automated model order reduction (MOR) of flexible aircrafts to construct linear parameter-varying (LPV) reduced order models (ROM) for aeroservoelasticity (ASE) analysis and control synthesis in broad flight parameter space. The novelty includes utilization of genetic algorithms (GAs) to automatically determine the states for reduction while minimizing the trial-and-error process and heuristics requirement to perform MOR; balanced truncation for unstable systems to achieve locally optimal realization of the full model; congruence transformation for "weak" fulfillment of state consistency across the entire flight parameter space; and ROM interpolation based on adaptive grid refinement to generate a globally functional LPV ASE ROM. The methodology is applied to the X-56A MUTT model currently being tested at NASA/AFRC for flutter suppression and gust load alleviation. Our studies indicate that X-56A ROM with less than one-seventh the number of states relative to the original model is able to accurately predict system response among all input-output channels for pitch, roll, and ASE control at various flight conditions. The GA-guided approach exceeds manual and empirical state selection in terms of efficiency and accuracy. The adaptive refinement allows selective addition of the grid points in the parameter space where flight dynamics varies dramatically to enhance interpolation accuracy without over-burdening controller synthesis and onboard memory efforts downstream. The present MOR framework can be used by control engineers for robust ASE controller synthesis and novel vehicle design.

  3. Low-thrombogenic fibrin-heparin coating promotes in vitro endothelialization

    Czech Academy of Sciences Publication Activity Database

    Kaplan, Ondřej; Hierlemann, T.; Krajewski, S.; Kurz, J.; Nevoralová, Martina; Houska, Milan; Riedel, Tomáš; Riedelová, Zuzana; Zárubová, Jana; Wendel, H. P.; Brynda, Eduard

    2017-01-01

    Roč. 105, č. 11 (2017), s. 2995-3005 ISSN 1549-3296 R&D Projects: GA MZd(CZ) NV15-29153A Institutional support: RVO:61389013 ; RVO:67985823 Keywords : fibrin-heparin coating * hemocompatibility * endothelialization Subject RIV: FA - Cardiovascular Diseases incl. Cardiotharic Surgery; FA - Cardiovascular Diseases incl. Cardiotharic Surgery (FGU-C) OBOR OECD: Cardiac and Cardiovascular systems; Cardiac and Cardiovascular systems (FGU-C) Impact factor: 3.076, year: 2016

  4. In vitro Heparin Precipitation in the Plasma of Euthyroid women with ...

    African Journals Online (AJOL)

    OBJECTIVE: Women with elevated Lp(a), who are susceptible to atherosclerosis, get to reduce, their cardiovascular disease by in-vivo administration of low dose heparin. And history of recurrent miscarriage associated with auto antibodies have had a high rate of life births in subsequent pregnancies when they were ...

  5. Graft patency after off-pump coronary artery bypass surgery is inferior even with identical heparinization protocols

    DEFF Research Database (Denmark)

    Houlind, Kim; Fenger-Grøn, Morten; Holme, Susanne J

    2014-01-01

    OBJECTIVE: To determine whether graft patency after on-pump and off-pump coronary artery bypass surgery is similar when performed using the same heparinization protocol. METHODS: In a randomized, controlled, multicenter trial, 900 patients more than 70 years of age received either on-pump or off......-pump coronary artery bypass surgery. Heparin was given to achieve an activated clotting time of 400 seconds before arteriotomy in both groups. After the procedure, protamine sulfate was given to revert the activated clotting time to less than 120 seconds. Coronary angiography was performed 6 months after...

  6. Venous thromboembolism in pregnancy: prophylaxis and treatment with low molecular weight heparin

    DEFF Research Database (Denmark)

    Andersen, Anita Sylvest; Berthelsen, Jørgen G; Bergholt, Thomas

    2010-01-01

    OBJECTIVE: To evaluate the safety of individually dosed low molecular weight heparin (LMWH) for prophylaxis and treatment of thromboembolic complications in pregnancy. DESIGN: Cohort study with a chronologic register-based control group. SETTING: Department of Obstetrics and Gynecology, Hillerød ...

  7. Role of the A+ helix in heparin binding to protein C inhibitor

    NARCIS (Netherlands)

    Elisen, M. G.; Maseland, M. H.; Church, F. C.; Bouma, B. N.; Meijers, J. C.

    1996-01-01

    Interactions between proteins and heparin(-like) structures involve electrostatic forces and structural features. Based on charge distributions in the linear sequence of protein C inhibitor (PCI), two positively charged regions of PCI were proposed as possible candidates for this interaction. The

  8. Comparison of a priori versus provisional heparin therapy on radial artery occlusion after transradial coronary angiography and patent hemostasis (from the PHARAOH Study).

    Science.gov (United States)

    Pancholy, Samir B; Bertrand, Olivier F; Patel, Tejas

    2012-07-15

    Systemic anticoagulation decreases the risk of radial artery occlusion (RAO) after transradial catheterization and standard occlusive hemostasis. We compared the efficacy and safety of provisional heparin use only when the technique of patent hemostasis was not achievable to standard a priori heparin administration after radial sheath introduction. Patients referred for coronary angiography were randomized in 2 groups. In the a priori group, 200 patients received intravenous heparin (50 IU/kg) immediately after sheath insertion. In the provisional group, 200 patients did not receive heparin during the procedure. After sheath removal, hemostasis was obtained using a TR band (Terumo corporation, Tokyo, Japan) with a plethysmography-guided patent hemostasis technique. In the provisional group, no heparin was given if radial artery patency could be obtained and maintained. If radial patency was not achieved, a bolus of heparin (50 IU/kg) was given. Radial artery patency was evaluated at 24 hours (early RAO) and 30 days after the procedure (late RAO) by plethysmography. Patent hemostasis was obtained in 67% in the a priori group and 74% in the provisional group (p = 0.10). Incidence of RAO remained similar in the 2 groups at the early (7.5% vs 7.0%, p = 0.84) and late (4.5% vs 5.0%, p = 0.83) evaluations. Women, patients with diabetes, patients having not received heparin, and patients without radial artery patency during hemostasis had more RAO. By multivariate analysis, patent radial artery during hemostasis (odds ratio [OR] 0.03, 95% confidence interval [CI] 0.004 to 0.28, p = 0.002) and diabetes (OR 11, 95% CI 3 to 38,p patent hemostasis is maintained. Copyright © 2012 Elsevier Inc. All rights reserved.

  9. Construction of mussel-inspired coating via the direct reaction of catechol and polyethyleneimine for efficient heparin immobilization

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Yujie [School of Material Science and Engineering, Southwest Jiaotong University, Chengdu 610031 (China); The Institute of Biomaterials and Surface Engineering, Southwest Jiaotong University, Chengdu 610031 (China); Luo, Rifang, E-mail: lrifang@126.com [School of Material Science and Engineering, Southwest Jiaotong University, Chengdu 610031 (China); The Institute of Biomaterials and Surface Engineering, Southwest Jiaotong University, Chengdu 610031 (China); Shen, Fangyu; Tang, Linlin [School of Material Science and Engineering, Southwest Jiaotong University, Chengdu 610031 (China); The Institute of Biomaterials and Surface Engineering, Southwest Jiaotong University, Chengdu 610031 (China); Wang, Jin, E-mail: jinxxwang@263.net [School of Material Science and Engineering, Southwest Jiaotong University, Chengdu 610031 (China); The Institute of Biomaterials and Surface Engineering, Southwest Jiaotong University, Chengdu 610031 (China); Huang, Nan [School of Material Science and Engineering, Southwest Jiaotong University, Chengdu 610031 (China); The Institute of Biomaterials and Surface Engineering, Southwest Jiaotong University, Chengdu 610031 (China)

    2015-02-15

    Highlights: • Catechol (CA) and PEI copolymerization was a mimetic and dopamine-like coating method. • CA/PEI film provided amine groups and was effective in heparin immobilization. • CA/PEI coating could inhibit smooth muscle cell proliferation. • CA/PEI coating did not show any significant cytotoxicity to endothelial cell. - Abstract: Dopamine could self-polymerize to form the coating on various substrates and the co-existence of catechols and amines was crucial in performing such polymerization process. In this work, a mimetic approach of coating formation was carried out based on the co-polymerization of catechol (CA) and polyethyleneimine (PEI). Mussel-inspired CA/PEI coating was deposited on 316L stainless steel (SS). Fourier transform infrared spectra (FTIR) and X-ray photoelectron spectroscopy (XPS) demonstrated the successful coating formation. QCM measurement showed good affinity of heparin immobilization on CA/PEI coating surface ascribed to the amine groups. Herein, vascular cell-material interactions like endothelial cells (ECs) and smooth muscle cells (SMCs) were also investigated. Interestingly, CA/PEI and heparin modified coatings presented no cytotoxicity to ECs, however to a certain extent, decreased SMCs proliferation. Moreover, heparin-binding surface presented significant anti-platelet adhesion and activation properties. These results effectively suggested that the mussel-inspired CA/PEI coating might be promising when served as a platform for biomolecule immobilization.

  10. Identification of chondroitin sulfate E proteoglycans and heparin proteoglycans in the secretory granules of human lung mast cells

    International Nuclear Information System (INIS)

    Stevens, R.L.; Austen, K.F.; Fox, C.C.; Lichtenstein, L.M.

    1988-01-01

    The predominant subclasses of mast cells in both the rat and the mouse can be distinguished from one another by their preferential synthesis of 35 S-labeled proteoglycans that contain either heparin or oversulfated chondroitin sulfate glycosaminoglycans. Although [ 35 S]heparin proteoglycans have been isolated from human lung mast cells of 40-70% purity and from a skin biopsy specimen of a patient with urticaria pigmentosa, no highly sulfated chondroitin sulfate proteoglycan has been isolated from any enriched or highly purified population of human mast cells. The authors demonstrate that human lung mast cells of 96% purity incorporate [ 35 S]sulfate into separate heparin and chondroitin sulfate proteoglycans in an ∼2:1 ratio. As assessed by HPLC of the chondroitinase ABC digests, the chondroitin [ 35 S]sulfate proteoglycans isolated from these human lung mast cells contain the same unusual chondroitin sulfate E disaccharide that is present in proteoglycans produced by interleukin 3-dependent mucosal-like mouse mast cells. Both the chondroitin [ 35 S]sulfate E proteoglycans and the [ 35 S]heparin proteoglycans were exocytosed from the [ 35 S]sulfate-labeled cells via perturbation of the IgE receptor, indicating that both types of 35 S-labeled proteoglycans reside in the secretory granules of these human lung mast cells

  11. Deep vein thrombosis, ecythyma gangrenosum and heparin-induced thrombocytopenia occurring in a man with a heterozygous Factor V Leiden mutation

    Directory of Open Access Journals (Sweden)

    Mariya Apostolova

    2012-11-01

    Full Text Available Skin necrosis and limb gangrene are occasional thrombotic manifestations of anticoagulation therapy. We report a man heterozygous for the Factor V Leiden (FVL mutation, and with a history of recurrent deep venous thrombosis, who initially presented with a necrotic skin lesion of the right flank while on warfarin therapy with a therapeutic international normalized ratio. Warfarin was discontinued and he received intravenous heparin. Thereafter he developed thrombocytopenia and pedal erythema and was diagnosed with heparin-induced thrombocytopenia (HIT. Heparin was replaced with argatroban. He ultimately underwent bilateral below-knee amputations for the thrombotic complications of the HIT. The initial necrotic lesion healed with antibiotics and wound care. Pathologic examination of multiple biopsy specimens revealed two separate lesions. One was necrotic tissue infiltrated with methicillin resistant Staphylococcus aureus having features of ecthyma gangrenosum. The second showed thrombotic changes consistent with HIT. The case illustrates the differential diagnosis of skin necrosis and limb gangrene in patients on warfarin and heparin, and also the clinical complexities that can occur in a FVL heterozygote.

  12. Comparison study of noise reduction algorithms in dual energy chest digital tomosynthesis

    Science.gov (United States)

    Lee, D.; Kim, Y.-S.; Choi, S.; Lee, H.; Choi, S.; Kim, H.-J.

    2018-04-01

    Dual energy chest digital tomosynthesis (CDT) is a recently developed medical technique that takes advantage of both tomosynthesis and dual energy X-ray images. However, quantum noise, which occurs in dual energy X-ray images, strongly interferes with diagnosis in various clinical situations. Therefore, noise reduction is necessary in dual energy CDT. In this study, noise-compensating algorithms, including a simple smoothing of high-energy images (SSH) and anti-correlated noise reduction (ACNR), were evaluated in a CDT system. We used a newly developed prototype CDT system and anthropomorphic chest phantom for experimental studies. The resulting images demonstrated that dual energy CDT can selectively image anatomical structures, such as bone and soft tissue. Among the resulting images, those acquired with ACNR showed the best image quality. Both coefficient of variation and contrast to noise ratio (CNR) were the highest in ACNR among the three different dual energy techniques, and the CNR of bone was significantly improved compared to the reconstructed images acquired at a single energy. This study demonstrated the clinical value of dual energy CDT and quantitatively showed that ACNR is the most suitable among the three developed dual energy techniques, including standard log subtraction, SSH, and ACNR.

  13. Potentiation of C1-esterase inhibitor by heparin and interactions with C1s protease as assessed by surface plasmon resonance.

    Science.gov (United States)

    Rajabi, Mohsen; Struble, Evi; Zhou, Zhaohua; Karnaukhova, Elena

    2012-01-01

    Human C1-esterase inhibitor (C1-INH) is a multifunctional plasma protein with a wide range of inhibitory and non-inhibitory properties, mainly recognized as a key down-regulator of the complement and contact cascades. The potentiation of C1-INH by heparin and other glycosaminoglycans (GAGs) regulates a broad spectrum of C1-INH activities in vivo both in normal and disease states. SCOPE OF RESEARCH: We have studied the potentiation of human C1-INH by heparin using Surface Plasmon Resonance (SPR), circular dichroism (CD) and a functional assay. To advance a SPR for multiple-unit interaction studies of C1-INH we have developed a novel (consecutive double capture) approach exploring different immobilization and layout. Our SPR experiments conducted in three different design versions showed marked acceleration in C1-INH interactions with complement protease C1s as a result of potentiation of C1-INH by heparin (from 5- to 11-fold increase of the association rate). Far-UV CD studies suggested that heparin binding did not alter C1-INH secondary structure. Functional assay using chromogenic substrate confirmed that heparin does not affect the amidolytic activity of C1s, but does accelerate its consumption due to C1-INH potentiation. This is the first report that directly demonstrates a significant acceleration of the C1-INH interactions with C1s due to heparin by using a consecutive double capture SPR approach. The results of this study may be useful for further C-INH therapeutic development, ultimately for the enhancement of current C1-INH replacement therapies. Published by Elsevier B.V.

  14. Venous thromboembolism in pregnancy: prophylaxis and treatment with low molecular weight heparin

    DEFF Research Database (Denmark)

    Andersen, Anita Sylvest; Berthelsen, Jørgen G.; Bergholt, Thomas

    2010-01-01

    OBJECTIVE: To evaluate the safety of individually dosed low molecular weight heparin (LMWH) for prophylaxis and treatment of thromboembolic complications in pregnancy. DESIGN: Cohort study with a chronologic register-based control group. SETTING: Department of Obstetrics and Gynecology, Hillerød...

  15. Effects of inhaled nitric oxide on hemostasis in healthy adults treated with heparin: a randomized, controlled, blinded crossover study

    Directory of Open Access Journals (Sweden)

    Goldstein Brahm

    2012-01-01

    Full Text Available Abstract Background Effects of nitric oxide (NO on hemostasis have been studied in various investigational settings, but data regarding inhaled NO on bleeding and platelet function are conflicting. It is not known if inhaled NO has an effect when administered with drugs that influence hemostasis. This trial evaluated effects of inhaled NO on hemostasis in the presence of heparin using aspirin as a positive control. Patients/Methods Twelve healthy adult males were enrolled in a single-center, randomized, single-blind, four-way crossover trial. Subjects received 80 ppm NO or medical air (placebo inhalation for 30 min with simultaneous injection of placebo or heparin. Aspirin capsules were used as a positive control. Parameters of hemostasis were measured before treatment and at post-treatment intervals. Results Activated clotting time (ACT, prothrombin time (PT and activated partial thromboplastin time (aPTT increased only in groups that received heparin. Areas under the curve for ACT in heparin groups receiving inhaled NO were judged to be equivalent to those receiving medical air for both 0- to 4-h (ratio: 1.00; 90% CI, 0.90-1.11 and 0- to 24-h time intervals (ratio: 1.01; 90% CI, 0.92-1.12. Changes in bleeding time and platelet aggregation were observed only in aspirin groups. No clinically significant changes in hemoglobin, red blood cell counts or haematocrit were observed in any group. Conclusions Inhaled NO, when administered with heparin, exhibited no significant additive effects on ACT, PT, aPTT, bleeding time or platelet aggregation.

  16. Simultaneous optical image compression and encryption using error-reduction phase retrieval algorithm

    International Nuclear Information System (INIS)

    Liu, Wei; Liu, Shutian; Liu, Zhengjun

    2015-01-01

    We report a simultaneous image compression and encryption scheme based on solving a typical optical inverse problem. The secret images to be processed are multiplexed as the input intensities of a cascaded diffractive optical system. At the output plane, a compressed complex-valued data with a lot fewer measurements can be obtained by utilizing error-reduction phase retrieval algorithm. The magnitude of the output image can serve as the final ciphertext while its phase serves as the decryption key. Therefore the compression and encryption are simultaneously completed without additional encoding and filtering operations. The proposed strategy can be straightforwardly applied to the existing optical security systems that involve diffraction and interference. Numerical simulations are performed to demonstrate the validity and security of the proposal. (paper)

  17. Sustained Thromboresistant Bioactivity with Reduced Intimal Hyperplasia of Heparin-Bonded Polytetrafluoroethylene Propaten Graft in a Chronic Canine Femoral Artery Bypass Model.

    Science.gov (United States)

    Freeman, John; Chen, Aaron; Weinberg, Roy J; Okada, Tamuru; Chen, Changyi; Lin, Peter H

    2018-05-01

    Bypass graft thrombosis remains a significant mode of failure in prosthetic graft revascularization. The purpose of this investigation was to evaluate the long-term thromboresistant effect of heparin-bonded expanded polytetrafluoroethylene (ePTFE) graft using Carmeda BioActive Surface technology in a canine model. Bilateral femorofemoral artery bypass grafts with ePTFE grafts were performed in 25 adult grayhound dogs. In each animal, a heparin-bonded ePTFE graft (Propaten, WL Gore) was placed on one side, whereas a control nonheparin graft was placed on the contralateral side. The graft patency was assessed at 1, 6, 12, 18, and 24 months (n = 5 per group) following the bypass. Heparin bioactivity of the graft material was analyzed. The effect of intimal hyperplasia was also assessed. All bypass grafts were patent at 1 month. Significantly greater patency rates were noted in the Propaten group compared to the control group at 12, 18, and 24 months, which were 84%, 80%, and 80% vs. 55%, 35%, and 20%, respectively (P  0.05). Heparin-bonded ePTFE graft provides a thromboresistant surface and reduced anastomotic intimal hyperplasia at 2 years. The stable heparin bioactivity of the Propaten graft confers an advantage in long-term graft patency. Copyright © 2017 The Author(s). Published by Elsevier Inc. All rights reserved.

  18. An error reduction algorithm to improve lidar turbulence estimates for wind energy

    Directory of Open Access Journals (Sweden)

    J. F. Newman

    2017-02-01

    Full Text Available Remote-sensing devices such as lidars are currently being investigated as alternatives to cup anemometers on meteorological towers for the measurement of wind speed and direction. Although lidars can measure mean wind speeds at heights spanning an entire turbine rotor disk and can be easily moved from one location to another, they measure different values of turbulence than an instrument on a tower. Current methods for improving lidar turbulence estimates include the use of analytical turbulence models and expensive scanning lidars. While these methods provide accurate results in a research setting, they cannot be easily applied to smaller, vertically profiling lidars in locations where high-resolution sonic anemometer data are not available. Thus, there is clearly a need for a turbulence error reduction model that is simpler and more easily applicable to lidars that are used in the wind energy industry. In this work, a new turbulence error reduction algorithm for lidars is described. The Lidar Turbulence Error Reduction Algorithm, L-TERRA, can be applied using only data from a stand-alone vertically profiling lidar and requires minimal training with meteorological tower data. The basis of L-TERRA is a series of physics-based corrections that are applied to the lidar data to mitigate errors from instrument noise, volume averaging, and variance contamination. These corrections are applied in conjunction with a trained machine-learning model to improve turbulence estimates from a vertically profiling WINDCUBE v2 lidar. The lessons learned from creating the L-TERRA model for a WINDCUBE v2 lidar can also be applied to other lidar devices. L-TERRA was tested on data from two sites in the Southern Plains region of the United States. The physics-based corrections in L-TERRA brought regression line slopes much closer to 1 at both sites and significantly reduced the sensitivity of lidar turbulence errors to atmospheric stability. The accuracy of machine

  19. Transfer of heparin polyion across a polarized water/ionic liquid membrane interface

    Czech Academy of Sciences Publication Activity Database

    Langmaier, Jan; Samec, Zdeněk; Samcová, E.; Tůma, P.

    2012-01-01

    Roč. 24, OCT 2012 (2012), s. 25-27 ISSN 1388-2481 R&D Projects: GA ČR GAP206/11/0707 Institutional support: RVO:61388955 Keywords : heparin polyion * ionic liquid membrane * amperometric detection Subject RIV: CG - Electrochemistry Impact factor: 4.425, year: 2012

  20. Low-molecular-weight heparin in the treatment of patients with venous thromboembolism

    NARCIS (Netherlands)

    tenCate, JW; Buller, HR; Gent, M; Hirsh, J; Prins, MH; Baildon, R; Lensing, AWA; Anderson, DR; vanBeek, EJR; Fiesinger, JN; Tijssen, JGP; vanBarneveld, A; Eimers, LT; Graafsma, YP; Hettiarachchi, R; Hutten, B; Redekop, K; Haley, S; LIberale, L; Finch, T; Whittaker, S; Wilkinson, L; Prandoni, P; Villalta, S; Girolami, B; Bagatella, P; Rossi, L; Girolami, A; Piovella, F; Barone, M; Beltrametti, C; Serafini, S; Siragusa, S; Ascari, E; Kovacs, MJ; Morrow, B; Kovacs, J; Kuijer, PMM; Koopman, MMW; Jagt, H; Weitz, J; Kearon, C; Biagioni, L; Haas, S; Lossner, F; Spengel, FA; Berger, M; Demers, C; Poulin, J; vanderMeer, J; Que, GTH; Smid, WM; Robinson, KS; Boyle, E; Leclerc, [No Value; StJacques, B; Finkenbine, S; Gallus, AS; Cohlan, D; Rich, C; Brandjes, DPM; Hoefnagel, CA; deRijk, M; Turkstra, F; Desjardins, L; CoteDesjardins, J; Couture, L; Ruel, M; Villenueve, J; Geerts, WH; Jay, RM; Code, EKI; Turpie, AGG; Johnson, J; Nguyen, P; Cusson, [No Value; Roy, S; Wells, PS; Bormanis, J; Goudie, D; Cruickshank, M; vonLewinski, M; Monreal, M; Sahuquillo, JC; Lafoz, E; Simonneau, G; Parent, F; Jagot, J; Douketis, JD; Kinnon, K; Ginsberg, JS; BrillEdwards, P; Donovan, D; Ockelford, PA; Kassis, J; Bornais, S; Planchon, B; ElKouri, D; Pistorius, MA; Escribano, M; Garrido, G; Chesterman, CN; Chong, BH; Pritchard, S; Cade, JF; Bynon, T; Stanford, J; Brien, WM; Palmer, B; Faivre, R; Petiteau, B; Manucci, PM; Moia, M; Bucciarelli, P

    1997-01-01

    Background Low-molecular-weight heparin is known to be safe and effective for the initial Treatment of patients with proximal deep-vein thrombosis. However, its application to patients with pulmonary embolism or previous episodes of thromboembolism has not been studied. Methods We randomly assigned

  1. Economic impact of enoxaparin versus unfractionated heparin for venous thromboembolism prophylaxis in patients with acute ischemic stroke: a hospital perspective of the PREVAIL trial.

    Science.gov (United States)

    Pineo, Graham; Lin, Jay; Stern, Lee; Subrahmanian, Tarun; Annemans, Lieven

    2012-03-01

    The PREVAIL (Prevention of VTE [venous thromboembolism] after acute ischemic stroke with LMWH [low-molecular-weight heparin] and UFH [unfractionated heparin]) study demonstrated a 43% VTE risk reduction with enoxaparin versus UFH in patients with acute ischemic stroke (AIS). A 1% rate of symptomatic intracranial and major extracranial hemorrhage was observed in both groups. To determine the economic impact, from a hospital perspective, of enoxaparin versus UFH for VTE prophylaxis after AIS. A decision-analytic model was constructed and hospital-based costs analyzed using clinical information from PREVAIL. Total hospital costs were calculated based on mean costs in the Premier™ database and from wholesalers acquisition data. Costs were also compared in patients with severe stroke (National Institutes of Health Stroke Scale [NIHSS] score ≥14) and less severe stroke (NIHSS score <14). The average cost per patient due to VTE or bleeding events was lower with enoxaparin versus UFH ($422 vs $662, respectively; net savings $240). The average anticoagulant cost, including drug-administration cost per patient, was lower with UFH versus enoxaparin ($259 vs $360, respectively; net savings $101). However, when both clinical events and drug-acquisition costs were considered, the total hospital cost was lower with enoxaparin versus UFH ($782 vs $922, respectively; savings $140). Hospital cost-savings were greatest ($287) in patients with NIHSS scores ≥14. The higher drug cost of enoxaparin was offset by the reduction in clinical events as compared to the use of UFH for VTE prophylaxis after an AIS, particularly in patients with severe stroke. Copyright © 2011 Society of Hospital Medicine.

  2. Metal-induced streak artifact reduction using iterative reconstruction algorithms in x-ray computed tomography image of the dentoalveolar region.

    Science.gov (United States)

    Dong, Jian; Hayakawa, Yoshihiko; Kannenberg, Sven; Kober, Cornelia

    2013-02-01

    The objective of this study was to reduce metal-induced streak artifact on oral and maxillofacial x-ray computed tomography (CT) images by developing the fast statistical image reconstruction system using iterative reconstruction algorithms. Adjacent CT images often depict similar anatomical structures in thin slices. So, first, images were reconstructed using the same projection data of an artifact-free image. Second, images were processed by the successive iterative restoration method where projection data were generated from reconstructed image in sequence. Besides the maximum likelihood-expectation maximization algorithm, the ordered subset-expectation maximization algorithm (OS-EM) was examined. Also, small region of interest (ROI) setting and reverse processing were applied for improving performance. Both algorithms reduced artifacts instead of slightly decreasing gray levels. The OS-EM and small ROI reduced the processing duration without apparent detriments. Sequential and reverse processing did not show apparent effects. Two alternatives in iterative reconstruction methods were effective for artifact reduction. The OS-EM algorithm and small ROI setting improved the performance. Copyright © 2012 Elsevier Inc. All rights reserved.

  3. Option-4 algorithm for Florida pocket depth probe: reduction in the variance of site-specific probeable crevice depth measurements.

    Science.gov (United States)

    Breen, H J; Rogers, P; Johnson, N W; Slaney, R

    1999-08-01

    Clinical periodontal measurement is plagued by many sources of error which result in aberrant values (outliers). This study sets out to compare probeable crevice depth measurements (PCD) selected by the option-4 algorithm against those recorded with a conventional double-pass method and to quantify any reduction in site-specific PCD variances. A single clinician recorded full-mouth PCD at 1 visit in 32 subjects (mean age 45.5 years) with moderately advanced chronic adult periodontitis. PCD was recorded over 2 passes at 6 sites per tooth with the Florida Pocket Depth Probes, a 3rd generation probe. The option-4 algorithm compared the 1st pass site-specific PCD value (PCD1) to the 2nd pass site-specific PCD value (PCD2) and, if the difference between these values was >1.00 mm, allowed the recording of a maximum of 2 further measurements (3rd and 4th pass measurements PCD3 and PCD4): 4 site-specific measure-meets were considered to be the maximum subject and tissue tolerance. The algorithm selected the 1st 2 measurements whose difference was difference Y) (Y=[(A-B)/A]X 100) and a 75% reduction in the median site-specific variance of PCD1/PCD2.

  4. Post-heparin plasma lipoprotein lipase, but not hepatic lipase activity, is related to plasma adiponectin in type 2 diabetic patients and healthy subjects

    NARCIS (Netherlands)

    De Vries, R; Wolffenbuttel, BHR; Sluiter, WJ; Van Tol, A; Dullaart, RPF

    2005-01-01

    The aim of this study was to determine the relationships of plasma adiponectin with post-heparin plasma lipoprotein lipase (LPL) and hepatic lipase (HL) activities, and to evaluate whether plasma adiponectin contributes to diabetes-associated dyslipidaemia. Plasma adiponectin, post-heparin plasma

  5. Enhancement of antibacterial properties of polyurethanes by chitosan and heparin immobilization

    International Nuclear Information System (INIS)

    Kara, Filiz; Aksoy, E. Ayse; Yuksekdag, Zehranur; Aksoy, Serpil; Hasirci, Nesrin

    2015-01-01

    Graphical abstract: - Highlights: • Polyurethane elastomer was synthesized in medical purity. • Chitosan (CH) and heparin (Hep) were immobilized on polyurethane films. • Modification with CH and Hep increased hydrophilicity and surface free energy. • Immobilized films had high antibacterial activity against four bacteria. • Bacterial adhesion significantly decreased on the modified surfaces. - Abstract: Being antibacterial is a required property for the materials used in medical devices and instruments. Polyurethanes (PUs) are one class of polymers widely used in the production of devices that especially come in contact with blood (e.g. heart valves, blood vessels, vascular grafts and catheters). In this study, hexamethylene diisocyanate based polyurethanes (PUh) were synthesized and antibacterial and anti-adhesive properties were added by immobilizing chitosan (CH) and heparin (Hep) on the samples of PUh via a stepwise process. Chemistry and topography of the modified film samples (PUh-CH and PUh-CH-Hep) were examined by Fourier Transform Infrared Spectrophotometry-Attenuated Total Reflectance (FTIR-ATR), Electron Spectroscopy for Chemical Analysis (ESCA) and Atomic Force Microscopy (AFM), and surface free energy (SFE) values after each step were determined by goniometer. PUh-CH and PUh-CH-Hep samples were found to be antibacterial against Staphylococcus aureus (S. aureus) and Staphylococcus epidermidis (S. epidermidis) (both Gram positive) and Escherichia coli (E. coli) and Pseudomonas aeruginosa (P. aeruginosa) (both Gram negative) bacteria, and bacterial adhesion results showed a significant decrease in the number of viable bacteria on both modified samples where PUh-CH-Hep was the most effective. The findings of this study show that polymeric surfaces can be effectively modified and converted to be antibacterial by chitosan and heparin immobilization, and presence of both chemicals enhance efficacy against bacteria.

  6. Enhancement of antibacterial properties of polyurethanes by chitosan and heparin immobilization

    Energy Technology Data Exchange (ETDEWEB)

    Kara, Filiz [Department of Chemistry, Faculty of Science, Gazi University, 06500 Ankara (Turkey); Aksoy, E. Ayse [Department of Basic Pharmaceutical Sciences, Faculty of Pharmacy, Hacettepe University, 06100 Ankara (Turkey); Yuksekdag, Zehranur [Biotechnology Laboratory, Department of Biology, Faculty of Science, Gazi University, 06500 Ankara (Turkey); Aksoy, Serpil [Department of Chemistry, Faculty of Science, Gazi University, 06500 Ankara (Turkey); Hasirci, Nesrin, E-mail: nhasirci@metu.edu.tr [BIOMATEN, Center of Excellence in Biomaterials and Tissue Engineering, Middle East Technical University, 06800 Ankara (Turkey); Department of Chemistry, Faculty of Arts and Sciences, Middle East Technical University, 06800 Ankara (Turkey)

    2015-12-01

    Graphical abstract: - Highlights: • Polyurethane elastomer was synthesized in medical purity. • Chitosan (CH) and heparin (Hep) were immobilized on polyurethane films. • Modification with CH and Hep increased hydrophilicity and surface free energy. • Immobilized films had high antibacterial activity against four bacteria. • Bacterial adhesion significantly decreased on the modified surfaces. - Abstract: Being antibacterial is a required property for the materials used in medical devices and instruments. Polyurethanes (PUs) are one class of polymers widely used in the production of devices that especially come in contact with blood (e.g. heart valves, blood vessels, vascular grafts and catheters). In this study, hexamethylene diisocyanate based polyurethanes (PUh) were synthesized and antibacterial and anti-adhesive properties were added by immobilizing chitosan (CH) and heparin (Hep) on the samples of PUh via a stepwise process. Chemistry and topography of the modified film samples (PUh-CH and PUh-CH-Hep) were examined by Fourier Transform Infrared Spectrophotometry-Attenuated Total Reflectance (FTIR-ATR), Electron Spectroscopy for Chemical Analysis (ESCA) and Atomic Force Microscopy (AFM), and surface free energy (SFE) values after each step were determined by goniometer. PUh-CH and PUh-CH-Hep samples were found to be antibacterial against Staphylococcus aureus (S. aureus) and Staphylococcus epidermidis (S. epidermidis) (both Gram positive) and Escherichia coli (E. coli) and Pseudomonas aeruginosa (P. aeruginosa) (both Gram negative) bacteria, and bacterial adhesion results showed a significant decrease in the number of viable bacteria on both modified samples where PUh-CH-Hep was the most effective. The findings of this study show that polymeric surfaces can be effectively modified and converted to be antibacterial by chitosan and heparin immobilization, and presence of both chemicals enhance efficacy against bacteria.

  7. A two-domain real-time algorithm for optimal data reduction: a case study on accelerator magnet measurements

    International Nuclear Information System (INIS)

    Arpaia, Pasquale; Buzio, Marco; Inglese, Vitaliano

    2010-01-01

    A real-time algorithm of data reduction, based on the combination of two lossy techniques specifically optimized for high-rate magnetic measurements in two domains (e.g. time and space), is proposed. The first technique exploits an adaptive sampling rule based on the power estimation of the flux increments in order to optimize the information to be gathered for magnetic field analysis in real time. The tracking condition is defined by the target noise level in the Nyquist band required by the post-processing procedure of magnetic analysis. The second technique uses a data reduction algorithm in order to improve the compression ratio while preserving the consistency of the measured signal. The allowed loss is set equal to the random noise level in the signal in order to force the loss and the noise to cancel rather than to add, by improving the signal-to-noise ratio. Numerical analysis and experimental results of on-field performance characterization and validation for two case studies of magnetic measurement systems for testing magnets of the Large Hadron Collider at the European Organization for Nuclear Research (CERN) are reported

  8. Observer Evaluation of a Metal Artifact Reduction Algorithm Applied to Head and Neck Cone Beam Computed Tomographic Images

    Energy Technology Data Exchange (ETDEWEB)

    Korpics, Mark; Surucu, Murat; Mescioglu, Ibrahim; Alite, Fiori; Block, Alec M.; Choi, Mehee; Emami, Bahman; Harkenrider, Matthew M.; Solanki, Abhishek A.; Roeske, John C., E-mail: jroeske@lumc.edu

    2016-11-15

    Purpose and Objectives: To quantify, through an observer study, the reduction in metal artifacts on cone beam computed tomographic (CBCT) images using a projection-interpolation algorithm, on images containing metal artifacts from dental fillings and implants in patients treated for head and neck (H&N) cancer. Methods and Materials: An interpolation-substitution algorithm was applied to H&N CBCT images containing metal artifacts from dental fillings and implants. Image quality with respect to metal artifacts was evaluated subjectively and objectively. First, 6 independent radiation oncologists were asked to rank randomly sorted blinded images (before and after metal artifact reduction) using a 5-point rating scale (1 = severe artifacts; 5 = no artifacts). Second, the standard deviation of different regions of interest (ROI) within each image was calculated and compared with the mean rating scores. Results: The interpolation-substitution technique successfully reduced metal artifacts in 70% of the cases. From a total of 60 images from 15 H&N cancer patients undergoing image guided radiation therapy, the mean rating score on the uncorrected images was 2.3 ± 1.1, versus 3.3 ± 1.0 for the corrected images. The mean difference in ranking score between uncorrected and corrected images was 1.0 (95% confidence interval: 0.9-1.2, P<.05). The standard deviation of each ROI significantly decreased after artifact reduction (P<.01). Moreover, a negative correlation between the mean rating score for each image and the standard deviation of the oral cavity and bilateral cheeks was observed. Conclusion: The interpolation-substitution algorithm is efficient and effective for reducing metal artifacts caused by dental fillings and implants on CBCT images, as demonstrated by the statistically significant increase in observer image quality ranking and by the decrease in ROI standard deviation between uncorrected and corrected images.

  9. Improved distribution and reduced toxicity of adriamycin bound to albumin-heparin microspheres

    NARCIS (Netherlands)

    Cremers, Harry; Cremers, H.F.M.; Bayon, L.G.; Verrijk, R.; Wesseling, M.M.; Wondergem, J.; Heuff, G.; Kwon, G.S.; Bae, Y.H.; Feijen, Jan; Kim, S.W.

    1995-01-01

    Adriamycin (ADR) was formulated in albumin-heparin conjugate microspheres (AHCMS) to improve site-specific delivery and to reduce the toxicity of the drug. The effect of formulating ADR in AHCMS was investigated upon intrahepatic administration to male Wag/Rij rats. After intraveno-portal (i.v.p.)

  10. A Suboptimal PTS Algorithm Based on Particle Swarm Optimization Technique for PAPR Reduction in OFDM Systems

    Directory of Open Access Journals (Sweden)

    Ho-Lung Hung

    2008-08-01

    Full Text Available A suboptimal partial transmit sequence (PTS based on particle swarm optimization (PSO algorithm is presented for the low computation complexity and the reduction of the peak-to-average power ratio (PAPR of an orthogonal frequency division multiplexing (OFDM system. In general, PTS technique can improve the PAPR statistics of an OFDM system. However, it will come with an exhaustive search over all combinations of allowed phase weighting factors and the search complexity increasing exponentially with the number of subblocks. In this paper, we work around potentially computational intractability; the proposed PSO scheme exploits heuristics to search the optimal combination of phase factors with low complexity. Simulation results show that the new technique can effectively reduce the computation complexity and PAPR reduction.

  11. A Suboptimal PTS Algorithm Based on Particle Swarm Optimization Technique for PAPR Reduction in OFDM Systems

    Directory of Open Access Journals (Sweden)

    Lee Shu-Hong

    2008-01-01

    Full Text Available Abstract A suboptimal partial transmit sequence (PTS based on particle swarm optimization (PSO algorithm is presented for the low computation complexity and the reduction of the peak-to-average power ratio (PAPR of an orthogonal frequency division multiplexing (OFDM system. In general, PTS technique can improve the PAPR statistics of an OFDM system. However, it will come with an exhaustive search over all combinations of allowed phase weighting factors and the search complexity increasing exponentially with the number of subblocks. In this paper, we work around potentially computational intractability; the proposed PSO scheme exploits heuristics to search the optimal combination of phase factors with low complexity. Simulation results show that the new technique can effectively reduce the computation complexity and PAPR reduction.

  12. A Spectral Algorithm for Envelope Reduction of Sparse Matrices

    Science.gov (United States)

    Barnard, Stephen T.; Pothen, Alex; Simon, Horst D.

    1993-01-01

    The problem of reordering a sparse symmetric matrix to reduce its envelope size is considered. A new spectral algorithm for computing an envelope-reducing reordering is obtained by associating a Laplacian matrix with the given matrix and then sorting the components of a specified eigenvector of the Laplacian. This Laplacian eigenvector solves a continuous relaxation of a discrete problem related to envelope minimization called the minimum 2-sum problem. The permutation vector computed by the spectral algorithm is a closest permutation vector to the specified Laplacian eigenvector. Numerical results show that the new reordering algorithm usually computes smaller envelope sizes than those obtained from the current standard algorithms such as Gibbs-Poole-Stockmeyer (GPS) or SPARSPAK reverse Cuthill-McKee (RCM), in some cases reducing the envelope by more than a factor of two.

  13. SU-E-J-218: Evaluation of CT Images Created Using a New Metal Artifact Reduction Reconstruction Algorithm for Radiation Therapy Treatment Planning

    Energy Technology Data Exchange (ETDEWEB)

    Niemkiewicz, J; Palmiotti, A; Miner, M; Stunja, L; Bergene, J [Lehigh Valley Health Network, Allentown, PA (United States)

    2014-06-01

    Purpose: Metal in patients creates streak artifacts in CT images. When used for radiation treatment planning, these artifacts make it difficult to identify internal structures and affects radiation dose calculations, which depend on HU numbers for inhomogeneity correction. This work quantitatively evaluates a new metal artifact reduction (MAR) CT image reconstruction algorithm (GE Healthcare CT-0521-04.13-EN-US DOC1381483) when metal is present. Methods: A Gammex Model 467 Tissue Characterization phantom was used. CT images were taken of this phantom on a GE Optima580RT CT scanner with and without steel and titanium plugs using both the standard and MAR reconstruction algorithms. HU values were compared pixel by pixel to determine if the MAR algorithm altered the HUs of normal tissues when no metal is present, and to evaluate the effect of using the MAR algorithm when metal is present. Also, CT images of patients with internal metal objects using standard and MAR reconstruction algorithms were compared. Results: Comparing the standard and MAR reconstructed images of the phantom without metal, 95.0% of pixels were within ±35 HU and 98.0% of pixels were within ±85 HU. Also, the MAR reconstruction algorithm showed significant improvement in maintaining HUs of non-metallic regions in the images taken of the phantom with metal. HU Gamma analysis (2%, 2mm) of metal vs. non-metal phantom imaging using standard reconstruction resulted in an 84.8% pass rate compared to 96.6% for the MAR reconstructed images. CT images of patients with metal show significant artifact reduction when reconstructed with the MAR algorithm. Conclusion: CT imaging using the MAR reconstruction algorithm provides improved visualization of internal anatomy and more accurate HUs when metal is present compared to the standard reconstruction algorithm. MAR reconstructed CT images provide qualitative and quantitative improvements over current reconstruction algorithms, thus improving radiation

  14. SU-E-J-218: Evaluation of CT Images Created Using a New Metal Artifact Reduction Reconstruction Algorithm for Radiation Therapy Treatment Planning

    International Nuclear Information System (INIS)

    Niemkiewicz, J; Palmiotti, A; Miner, M; Stunja, L; Bergene, J

    2014-01-01

    Purpose: Metal in patients creates streak artifacts in CT images. When used for radiation treatment planning, these artifacts make it difficult to identify internal structures and affects radiation dose calculations, which depend on HU numbers for inhomogeneity correction. This work quantitatively evaluates a new metal artifact reduction (MAR) CT image reconstruction algorithm (GE Healthcare CT-0521-04.13-EN-US DOC1381483) when metal is present. Methods: A Gammex Model 467 Tissue Characterization phantom was used. CT images were taken of this phantom on a GE Optima580RT CT scanner with and without steel and titanium plugs using both the standard and MAR reconstruction algorithms. HU values were compared pixel by pixel to determine if the MAR algorithm altered the HUs of normal tissues when no metal is present, and to evaluate the effect of using the MAR algorithm when metal is present. Also, CT images of patients with internal metal objects using standard and MAR reconstruction algorithms were compared. Results: Comparing the standard and MAR reconstructed images of the phantom without metal, 95.0% of pixels were within ±35 HU and 98.0% of pixels were within ±85 HU. Also, the MAR reconstruction algorithm showed significant improvement in maintaining HUs of non-metallic regions in the images taken of the phantom with metal. HU Gamma analysis (2%, 2mm) of metal vs. non-metal phantom imaging using standard reconstruction resulted in an 84.8% pass rate compared to 96.6% for the MAR reconstructed images. CT images of patients with metal show significant artifact reduction when reconstructed with the MAR algorithm. Conclusion: CT imaging using the MAR reconstruction algorithm provides improved visualization of internal anatomy and more accurate HUs when metal is present compared to the standard reconstruction algorithm. MAR reconstructed CT images provide qualitative and quantitative improvements over current reconstruction algorithms, thus improving radiation

  15. Immobilization of heparin to EDC/NHS-crosslinked collagen. Characterization and in vitro evaluation

    NARCIS (Netherlands)

    Wissink, M.J.B.; Beernink, R.; Pieper, J.S.; Poot, Andreas A.; Engbers, G.H.M.; Beugeling, T.; Beugeling, T.; van Aken, W.G.; Feijen, Jan

    2001-01-01

    In the present study, heparin immobilization to a non-cytotoxic crosslinked collagen substrate for endothelial cell seeding was investigated. Crosslinking of collagen using N-(3-dimethylaminopropyl)-N′-ethylcarbodiimide (EDC) and N-hydroxysuccinimide (NHS) resulted in a material containing 14 free

  16. The impact of heparin-coated circuits on hemodynamics during and after cardiopulmonary bypass

    NARCIS (Netherlands)

    de Vroege, R; Huybregts, R; van Oeveren, W; van Klarenbosch, J; Linley, G; Mutlu, J; Jansen, E; Hack, E; Eijsman, L; Wildevuur, C

    This study was performed to investigate if heparin-coated extracorporeal circuits can reduce the systemic inflammatory reaction with the subsequent release of vasoactive substances during and after cardiopulmonary bypass. Fifty-one patients scheduled for coronary artery bypass grafting were perfused

  17. Angiogenic Factor Profiles in Pregnant Women With a History of Early-Onset Severe Preeclampsia Receiving Low-Molecular-Weight Heparin Prophylaxis.

    Science.gov (United States)

    Lecarpentier, Edouard; Gris, Jean Christophe; Cochery-Nouvellon, Eva; Mercier, Erick; Touboul, Cyril; Thadhani, Ravi; Karumanchi, S Ananth; Haddad, Bassam

    2018-01-01

    To evaluate whether daily low-molecular-weight (LMW) heparin prophylaxis during pregnancy alters profile of circulating angiogenic factors that have been linked with the pathogenesis of preeclampsia and fetal growth restriction. This is a planned ancillary study of the Heparin-Preeclampsia trial, a randomized trial in pregnant women with a history of severe early-onset preeclampsia (less than 34 weeks of gestation). In the parent study, all women were treated with aspirin and then randomized to receive LMW heparin or aspirin alone. In this study, we measured serum levels of circulating angiogenic factors (soluble fms-like tyrosine kinase-1, placental growth factor, and soluble endoglin by immunoassay) at the following gestational windows: 10-13 6/7 weeks, 14-17 6/7 weeks, 18-21 6/7 weeks, 22-25 6/7 weeks, 26-29 6/7 weeks, 30-33 6/7 weeks, and 34-37 6/7 weeks. Samples were available from 185 patients: LMW heparin+aspirin (n=92) and aspirin alone (n=93). The two groups had comparable baseline characteristics and had similar adverse composite outcomes (35/92 [38.0%] compared with 36/93 [38.7%]; P=.92). There were no significant differences in serum levels of soluble fms-like tyrosine kinase-1, placental growth factor, and soluble endoglin in the participants who received LMW heparin and aspirin compared with those who received aspirin alone regardless of gestational age period. Finally, women who developed an adverse composite outcome at less than 34 weeks of gestation demonstrated significant alterations in serum angiogenic profile as early as 10-13 6/7 weeks that was most dramatic 6-8 weeks preceding delivery. Prophylactic LMW heparin therapy when beginning from before 14 weeks of gestation with aspirin during pregnancy is not associated with an improved angiogenic profile. This may provide a molecular explanation for the lack of clinical benefit noted in recent trials. ClinicalTrials.gov, NCT00986765.

  18. Bivalirudin is superior to heparins alone with bailout GP IIb/IIIa inhibitors in patients with ST-segment elevation myocardial infarction transported emergently for primary percutaneous coronary intervention

    DEFF Research Database (Denmark)

    Zeymer, Uwe; van 't Hof, Arnoud; Adgey, Jennifer

    2014-01-01

    was the composites of death or non-CABG-related major bleeding at 30 days. This pre-specified analysis compared patients receiving bivalirudin (n = 1089) with those receiving heparins with routine upstream GPI (n = 649) and those receiving heparins only with GPI use restricted to bailout (n = 460). The primary...... outcome death and major bleeding occurred in 5.1% with bivalirudin, 7.6% with heparin plus routine GPI (HR 0.67 and 95% CI 0.46-0.97, P = 0.034), and 9.8% with heparins plus bailout GPI (HR 0.52 and 95% CI 0.35-0.75, P = 0.006). Following adjustment by logistic regression, bivalirudin was still associated...

  19. Heparin sodium compliance to the new proposed USP monograph: elucidation of a minor structural modification responsible for a process dependent 2.10 ppm NMR signal.

    Science.gov (United States)

    Mourier, Pierre A J; Guichard, Olivier Y; Herman, Fréderic; Viskov, Christian

    2011-01-25

    Heparin is a highly sulfated hetero polysaccharide mixture found and extracted from mammalian tissues. It has been widely used as an anticoagulant drug during the past decades. In the new proposed USP heparin monograph, the ¹H NMR acceptance criteria to prevent contamination by over sulfated chondroitin sulfate (OSCS), or other persulfated glycosaminoglycans, specifies that no unidentified signals greater than 4% of the mean of signal height of 1 and 2 should be present in the following ranges: 0.10-2.00, 2.10-3.20, and 5.70-8.00 ppm. However, those criteria do not take into account the impact of potential structural modifications generated by the heparin manufacturing processes. In fact, starting from pig mucosa, heparin purification involves oxidizing reagents such as sodium peroxide, potassium permanganate and peracetic acid. In the present work, we demonstrate that potassium permanganate treated heparins show a small but characteristic extra signal at 2.10 ppm. Controlled heparinase I depolymerisation is used to target and excise the oligosaccharide responsible for this extra signal from the polysaccharide backbone. By using orthogonal chromatographic techniques, the fingerprint oligosaccharide was isolated and its structure elucidated. Without the identification of this structural moiety, such purified heparins may have been considered as non-compliant drug substance and not suitable for pharmaceutical use. Copyright © 2010 Elsevier B.V. All rights reserved.

  20. Comparison of digoxin concentration in plastic serum tubes with clot activator and heparinized plasma tubes.

    Science.gov (United States)

    Dukić, Lora; Simundić, Ana-Maria; Malogorski, Davorin

    2014-01-01

    Sample type recommended by the manufacturer for the digoxin Abbott assay is either serum collected in glass tubes or plasma (sodium heparin, lithium heparin, citrate, EDTA or oxalate as anticoagulant) collected in plastic tubes. In our hospital samples are collected in plastic tubes. Our hypothesis was that the serum sample collected in plastic serum tube can be used interchangeably with plasma sample for measurement of digoxin concentration. Our aim was verification of plastic serum tubes for determination of digoxin concentration. Concentration of digoxin was determined simultaneously in 26 venous blood plasma (plastic Vacuette, LH Lithium heparin) and serum (plastic Vacuette, Z Serum Clot activator; both Greiner Bio-One GmbH, Kremsmünster, Austria) samples, on Abbott AxSYM analyzer using the original Abbott Digoxin III assay (Abbott, Wiesbaden, Germany). Tube comparability was assessed using the Passing Bablok regression and Bland-Altman plot. Serum and plasma digoxin concentrations are comparable. Passing Bablok intercept (0.08 [95% CI = -0.10 to 0.20]) and slope (0.99 [95% CI = 0.92 to 1.11]) showed there is no constant or proportional error. Blood samples drawn in plastic serum tubes and plastic plasma tubes can be interchangeably used for determination of digoxin concentration.

  1. Relationship between heparin anticoagulation and clinical outcomes in coronary stent intervention: observations from the ESPRIT trial.

    Science.gov (United States)

    Tolleson, Thaddeus R; O'Shea, J Conor; Bittl, John A; Hillegass, William B; Williams, Kathryn A; Levine, Glenn; Harrington, Robert A; Tcheng, James E

    2003-02-05

    We evaluated the relationship between the degree of heparin anticoagulation and clinical efficacy and bleeding in patients undergoing contemporary percutaneous coronary intervention (PCI) with stent implantation. Despite universal acceptance of heparin anticoagulation as a standard of care in PCI, considerable controversy still exists regarding the appropriate dosing of heparin. The study population (n = 2,064) comprised all patients enrolled in the Enhanced Suppression of the Platelet IIb/IIIa Receptor with Integrilin Therapy (ESPRIT) trial. The index activated clotting time (ACT) was defined as the ACT measured after the last heparin dose and before first device activation and was correlated with outcome and bleeding events. No association was observed between decreasing ACT levels and the rate of ischemic events in the treatment or placebo arms. The incidence of the primary composite end point (death, myocardial infarction, urgent target vessel revascularization, and thrombotic bailout glycoprotein IIb/IIIa inhibitor therapy at 48 h) was actually lowest in the lowest ACT tertile for both the placebo (10.0%) and treatment groups (6.1%). When analyzed by tertile, major bleeding rates did not increase in the lowest ACT tertile in patients given placebo (0.6%) versus those receiving eptifibatide (0.7%). Major bleeding rates increased as the ACT increased in the eptifibatide-treated patients. Ischemic end points in patients undergoing contemporary PCI with stent placement do not increase by decreasing ACT levels, at least to a level of 200 s. Bleeding events do increase with increasing ACT levels and are enhanced with eptifibatide treatment. An ACT of 200 to 250 s is reasonable in terms of efficacy and safety with the use of contemporary technology and pharmacotherapy.

  2. Influence of heparin on the assay of amitriptyline, clomipramine, and their metabolites

    NARCIS (Netherlands)

    Levering, S.C.M.; Oostelbos, M.C.J.M.; Toll, P.J.M.M.; Loonen, A.J.M.

    1996-01-01

    In this study the effect of the use of lithium heparin containers on the plasma levels of amitriptyline, clomipramine, and their metabolites was investigated. Twenty-five patients (10 men and 15 women, mean age 51.8 ± 14.9 years) taking either amitriptyline or clomipramine in a daily dosage varying

  3. Developing a Highly Active Blood Anticoagulant—a Heparin Complex with Glutamic Acid—by Simulating Chemical Equilibria Based on pH-Metric Data

    Science.gov (United States)

    Nikolaeva, L. S.; Semenov, A. N.

    2018-02-01

    The anticoagulant activity of high-molecular-weight heparin is increased by developing a new highly active heparin complex with glutamate using the thermodynamic model of chemical equilibria based on pH-metric data. The anticoagulant activity of the developed complexes is estimated in the pH range of blood plasma according to the drop in the calculated equilibrium Ca2+ concentration associated with the formation of mixed ligand complexes of Ca2+ ions, heparin (Na4hep), and glutamate (H2Glu). A thermodynamic model is calculated by mathematically modelling chemical equilibria in the CaCl2-Na4hep-H2Glu-H2O-NaCl system in the pH range of 2.30 ≤ pH ≤ 10.50 in diluted saline that acts as a background electrolyte (0.154 M NaCl) at 37°C and initial concentrations of the main components of ν × 10-3 M, where n ≤ 4. The thermodynamic model is used to determine the main complex of the monomeric unit of heparin with glutamate (HhepGlu5-) and the most stable mixed ligand complex of Ca2+ with heparin and glutamate (Ca2hepGlu2-) in the pH range of blood plasma (6.80 ≤ pH ≤ 7.40). It is concluded that the Ca2hepGlu2- complex reduces the Ca2+ concentration 107 times more than the Ca2+ complex with pure heparin. The anticoagulant effect of the developed HhepGlu5- complex is confirmed in vitro and in vivo via coagulation tests on the blood plasma of laboratory rats. Additional antithrombotic properties of the developed complex are identified. The new highly active anticoagulant, HhepGlu5- complex with additional antithrombotic properties, is patented.

  4. A randomised controlled trial of Heparin versus EthAnol Lock THerapY for the prevention of Catheter Associated infecTion in Haemodialysis patients – the HEALTHY-CATH trial

    Directory of Open Access Journals (Sweden)

    Broom Jennifer K

    2012-11-01

    Full Text Available Abstract Background Tunnelled central venous dialysis catheter use is significantly limited by the occurrence of catheter-related infections. This randomised controlled trial assessed the efficacy of a 48 hour 70% ethanol lock vs heparin locks in prolonging the time to the first episode of catheter related blood stream infection (CRBSI. Methods Patients undergoing haemodialysis (HD via a tunnelled catheter were randomised 1:1 to once per week ethanol locks (with two heparin locks between other dialysis sessions vs thrice per week heparin locks. Results Observed catheter days in the heparin (n=24 and ethanol (n=25 groups were 1814 and 3614 respectively. CRBSI occurred at a rate of 0.85 vs. 0.28 per 1000 catheter days in the heparin vs ethanol group by intention to treat analysis (incident rate ratio (IRR for ethanol vs. heparin 0.17; 95%CI 0.02-1.63; p=0.12. Flow issues requiring catheter removal occurred at a rate of 1.6 vs 1.4 per 1000 catheter days in the heparin and ethanol groups respectively (IRR 0.85; 95% CI 0.20-3.5 p =0.82 (for ethanol vs heparin. Conclusions Catheter survival and catheter-related blood stream infection were not significantly different but there was a trend towards a reduced rate of infection in the ethanol group. This study establishes proof of concept and will inform an adequately powered multicentre trial to definitively examine the efficacy and safety of ethanol locks as an alternative to current therapies used in the prevention of catheter-associated blood stream infections in patients dialysing with tunnelled catheters. Trial Registration Australian New Zealand Clinical Trials Registry ACTRN12609000493246

  5. The Scandinavian Propaten(®) trial - 1-year patency of PTFE vascular prostheses with heparin-bonded luminal surfaces compared to ordinary pure PTFE vascular prostheses - a randomised clinical controlled multi-centre trial.

    Science.gov (United States)

    Lindholt, J S; Gottschalksen, B; Johannesen, N; Dueholm, D; Ravn, H; Christensen, E D; Viddal, B; Flørenes, T; Pedersen, G; Rasmussen, M; Carstensen, M; Grøndal, N; Fasting, H

    2011-05-01

    To compare 1-year potencies' of heparin-bonded PTFE [(Hb-PTFE) (Propaten(®))] grafts with those of ordinary polytetraflouroethylene (PTFE) grafts in a blinded, randomised, clinically controlled, multi-centre study. Eleven Scandinavian centres enrolled 569 patients with chronic functional or critical lower limb ischaemia who were scheduled to undergo femoro-femoral bypass or femoro-poplitaeal bypass. The patients were randomised 1:1 stratified by centre. Patency was assessed by duplex ultrasound scanning. A total of 546 patients (96%) completed the study with adequate follow-up. Perioperative bleeding was, on average, 370 ml with PTFE grafts and 399 ml with Heparin-bonded PTFE grafts (p = 0.32). Overall, primary patency after 1 year was 86.4% for Hb-PTFE grafts and 79.9% for PTFE grafts (OR = 0.627, 95% CI: 0.398; 0.989, p = 0.043). Secondary patency was 88% in Hb-PTFE grafts and 81% in PTFE grafts (OR = 0.569 (0.353; 0.917, p = 0.020)). Subgroup analyses revealed that significant reduction in risk (50%) was observed when Hb-PTFE was used for femoro-poplitaeal bypass (OR = 0.515 (0.281; 0.944, p = 0.030)), and a significant reduction in risk (50%) was observed with Hb-PTFE in cases with critical ischaemia (OR = 0.490 (0.249; 0.962, p = 0.036)). The Hb-PTFE graft significantly reduced the overall risk of primary graft failure by 37%. Risk reduction was 50% in femoro-poplitaeal bypass cases and in cases with critical ischaemia. Copyright © 2011. Published by Elsevier Ltd.

  6. CCN5 modulates the antiproliferative effect of heparin and regulates cell motility in vascular smooth muscle cells

    Directory of Open Access Journals (Sweden)

    Castellot John J

    2003-11-01

    Full Text Available Abstract Background Vascular smooth muscle cell (VSMC hyperplasia plays an important role in both chronic and acute vascular pathologies including atherosclerosis and restenosis. Considerable work has focused on the mechanisms regulating VSMC proliferation and motility. Earlier work in our lab revealed a novel growth arrest-specific (gas gene induced in VSMC exposed to the antiproliferative agent heparin. This gene is a member of the CCN family and has been given the name CCN5. The objective of the present study is to elucidate the function of CCN5 protein and to explore its mechanism of action in VSMC. Results Using RNA interference (RNAi, we first demonstrate that CCN5 is required for the antiproliferative effect of heparin in VSMC. We also use this gene knockdown approach to show that CCN5 is an important negative regulator of motility. To explore the mechanism of action of CCN5 on VSMC motility, we use RNAi to demonstrate that knock down of CCN5 up regulates expression of matrix metalloproteinase-2 (MMP-2, an important stimulator of motility in VSMC. In addition, forced expression of CCN5 via adenovirus results in reduced MMP-2 activity, this also corroborates the gene knock down results. Finally, we show that loss of CCN5 expression in VSMC causes changes in VSMC morphology and cytoskeletal organization, including a reduction in the amount and macromolecular assembly of smooth muscle cell α-actin. Conclusions This work provides important new insights into the regulation of smooth muscle cell proliferation and motility by CCN5 and may aid the development of therapies for vascular diseases.

  7. Fondaparinux for intra and perioperative anticoagulation in patients with heparin-induced thrombocytopenia candidates for peripheral vascular surgery: Report of 4 cases.

    Science.gov (United States)

    Illuminati, Giulio; Calio', Francesco G; Pizzardi, Giulia; Amatucci, Chiara; Masci, Federica; Palumbo, Piergaspare

    2016-01-01

    Intra and perioperative anticoagulation in patients with heparin induced thrombocytopenia (HIT), candidates for peripheral vascular surgery remains a challenge, as the best alternative to heparin has not yet been established. We evaluated the off-label use of fondaparinux in four patients with HIT, undergoing peripheral vascular surgery procedures. Four patients of whom 3 men of a mean age of 66 years, with proven heparin induced thrombocytopenia (HIT) underwent two axillo-femoral bypasses, one femoro-popliteal bypass and one resection of a splenic artery aneurysm under fondaparinux. No intra or perioperative bleeding or thrombosis of new onset was observed. In the absence of a valid alternative to heparin for intra and perioperative anticoagulation in HIT, several other anticoagulants can be used in an off-label setting. However, no general consensus exist on which should be the one of choice. In this small series fondaparinux appeared to be both safe and effective. These preliminary results seem to justify the off-label use of fondaparinux for intra and perioperative anticoagulation in patients with HIT, candidates for peripheral vascular surgery interventions. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  8. A verified LLL algorithm

    NARCIS (Netherlands)

    Divasón, Jose; Joosten, Sebastiaan; Thiemann, René; Yamada, Akihisa

    2018-01-01

    The Lenstra-Lenstra-Lovász basis reduction algorithm, also known as LLL algorithm, is an algorithm to find a basis with short, nearly orthogonal vectors of an integer lattice. Thereby, it can also be seen as an approximation to solve the shortest vector problem (SVP), which is an NP-hard problem,

  9. Human recombinant interleukin-1 beta- and tumor necrosis factor alpha-mediated suppression of heparin-like compounds on cultured porcine aortic endothelial cells

    International Nuclear Information System (INIS)

    Kobayashi, M.; Shimada, K.; Ozawa, T.

    1990-01-01

    Cytokines are known to tip the balance of the coagulant-anticoagulant molecules on the endothelial cell surface toward intravascular coagulation. Their effects on endothelial cell surface-associated heparin-like compounds have not been examined yet. Incorporation of [35S]sulfate into heparan sulfate on cultured porcine aortic endothelial cells was suppressed by human recombinant interleukin-1 beta (rIL-1 beta) or tumor necrosis factor alpha (rTNF alpha) in a dose- and time-dependent manner with little effect on cell number, protein content, and [3H]leucine incorporation of cells. Maximal inhibition was achieved by incubation of cells with 100 ng/ml of rIL-1 beta or 5 ng/ml of rTNF alpha for 12-24 hours, resulting in a reduction of the synthesis of heparan sulfate on the cell surface by approximately 50%. The dose dependency was consistent with that seen in the stimulation of endothelial cell procoagulant activity by each cytokine. The suppression of heparan sulfate synthesis was sustained for at least 48 hours after pretreatment of cells with cytokines and was unchanged after the addition of indomethacin or polymyxin B. The rate of degradation of prelabeled 35S-heparan sulfate on the cell surface was not altered by cytokine treatments. Neither the size, the net negative charge, nor the proportion of the molecule with high affinity for antithrombin III of endothelial cell heparan sulfate was changed by cytokines. Furthermore, specific binding of 125I-labeled antithrombin III to the endothelial cell surface was reduced to 40-60% of control by cytokines. In parallel with reduction in binding, antithrombin III cofactor activity was partially diminished in cytokine-treated endothelial cells. Thus, cytokine-mediated suppression of heparin-like substance on endothelial cells appears to be another cytokine-inducible endothelial effects affecting coagulation

  10. Optical sensing of sulfate by polymethinium salt receptors: colorimetric sensor for heparin

    Czech Academy of Sciences Publication Activity Database

    Bříza, T.; Kejík, Z.; Císařová, I.; Králová, Jarmila; Martásek, P.; Král, V.

    2008-01-01

    Roč. 16, - (2008), s. 1901-1903 ISSN 1359-7345 R&D Projects: GA AV ČR KAN200200651; GA ČR(CZ) GA203/06/1038 Institutional research plan: CEZ:AV0Z50520514 Keywords : colorimetric sensor * heparin * polymethinium salt Subject RIV: EB - Genetics ; Molecular Biology Impact factor: 5.340, year: 2008

  11. Low dose intravesical heparin as prophylaxis against recurrent noninvasive (stage Ta) bladder cancer

    DEFF Research Database (Denmark)

    Bitsch, M; Hermann, G G; Andersen, J P

    1990-01-01

    A controlled randomized clinical trial was conducted to examine the efficacy of topical low dose heparin (0.125 gm./l., 25,000 units per l.) as prophylaxis against recurrent noninvasive (stage Ta) transitional cell bladder cancer. Transurethral tumor resection was done with irrigation fluid conta...

  12. Cooperative vehicles for robust traffic congestion reduction: An analysis based on algorithmic, environmental and agent behavioral factors.

    Directory of Open Access Journals (Sweden)

    Prajakta Desai

    Full Text Available Traffic congestion continues to be a persistent problem throughout the world. As vehicle-to-vehicle communication develops, there is an opportunity of using cooperation among close proximity vehicles to tackle the congestion problem. The intuition is that if vehicles could cooperate opportunistically when they come close enough to each other, they could, in effect, spread themselves out among alternative routes so that vehicles do not all jam up on the same roads. Our previous work proposed a decentralized multiagent based vehicular congestion management algorithm entitled Congestion Avoidance and Route Allocation using Virtual Agent Negotiation (CARAVAN, wherein the vehicles acting as intelligent agents perform cooperative route allocation using inter-vehicular communication. This paper focuses on evaluating the practical applicability of this approach by testing its robustness and performance (in terms of travel time reduction, across variations in: (a environmental parameters such as road network topology and configuration; (b algorithmic parameters such as vehicle agent preferences and route cost/preference multipliers; and (c agent-related parameters such as equipped/non-equipped vehicles and compliant/non-compliant agents. Overall, the results demonstrate the adaptability and robustness of the decentralized cooperative vehicles approach to providing global travel time reduction using simple local coordination strategies.

  13. Cooperative vehicles for robust traffic congestion reduction: An analysis based on algorithmic, environmental and agent behavioral factors.

    Science.gov (United States)

    Desai, Prajakta; Loke, Seng W; Desai, Aniruddha

    2017-01-01

    Traffic congestion continues to be a persistent problem throughout the world. As vehicle-to-vehicle communication develops, there is an opportunity of using cooperation among close proximity vehicles to tackle the congestion problem. The intuition is that if vehicles could cooperate opportunistically when they come close enough to each other, they could, in effect, spread themselves out among alternative routes so that vehicles do not all jam up on the same roads. Our previous work proposed a decentralized multiagent based vehicular congestion management algorithm entitled Congestion Avoidance and Route Allocation using Virtual Agent Negotiation (CARAVAN), wherein the vehicles acting as intelligent agents perform cooperative route allocation using inter-vehicular communication. This paper focuses on evaluating the practical applicability of this approach by testing its robustness and performance (in terms of travel time reduction), across variations in: (a) environmental parameters such as road network topology and configuration; (b) algorithmic parameters such as vehicle agent preferences and route cost/preference multipliers; and (c) agent-related parameters such as equipped/non-equipped vehicles and compliant/non-compliant agents. Overall, the results demonstrate the adaptability and robustness of the decentralized cooperative vehicles approach to providing global travel time reduction using simple local coordination strategies.

  14. A heparin-functionalized carbon nanotube-based affinity biosensor for dengue virus.

    Science.gov (United States)

    Wasik, Daniel; Mulchandani, Ashok; Yates, Marylynn V

    2017-05-15

    Dengue virus is an arthropod-borne virus transmitted primarily by Aedes mosquitos and is major cause of disease in tropical and subtropical regions. Colloquially known as Dengue Fever, infection can cause hemorrhagic disorders and death in humans and non-human primates. We report a novel electronic biosensor based on a single-walled carbon nanotube network chemiresistive transducer that is functionalized with heparin for low-cost, label-free, ultra-sensitive, and rapid detection of whole dengue virus (DENV). Heparin, an analog of the heparan sulfate proteoglycans that are receptors for dengue virus during infection of Vero cells and hepatocytes, was used for the first time in a biosensor as a biorecognition element instead of traditional antibody. Detection of DENV in viral culture supernatant has similar sensitivity as the corresponding viral titer in phosphate buffer despite the presence of growth media and Vero cell lysate. The biosensor demonstrated sensitivity within the clinically relevant range for humans and infected Aedes aegypti. It has potential application in clinical diagnosis and can improve point-of-care diagnostics of dengue infection. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Covalent Binding of Heparin to Functionalized PET Materials for Improved Haemocompatibility

    Directory of Open Access Journals (Sweden)

    Metod Kolar

    2015-03-01

    Full Text Available The hemocompatibility of vascular grafts made from poly(ethylene terephthalate (PET is insufficient due to the rapid adhesion and activation of blood platelets that occur upon incubation with whole blood. PET polymer was treated with NHx radicals created by passing ammonia through gaseous plasma formed by a microwave discharge, which allowed for functionalization with amino groups. X-ray photoelectron spectroscopy characterization using derivatization with 4-chlorobenzaldehyde indicated that approximately 4% of the –NH2 groups were associated with the PET surface after treatment with the gaseous radicals. The functionalized polymers were coated with an ultra-thin layer of heparin and incubated with fresh blood. The free-hemoglobin technique, which is based on the haemolysis of erythrocytes, indicated improved hemocompatibility, which was confirmed by imaging the samples using confocal optical microscopy. A significant decrease in number of adhered platelets was observed on such samples. Proliferation of both human umbilical vein endothelial cells and human microvascular endothelial cells was enhanced on treated polymers, especially after a few hours of cell seeding. Thus, the technique represents a promising substitute for wet-chemical modification of PET materials prior to coating with heparin.

  16. Successful Use of Alternative Anticoagulants in the Management of Heparin-induced Thrombocytopenia with Thrombotic Complications: Report of 5 cases and review of literature.

    LENUS (Irish Health Repository)

    Alkindi, Salam

    2011-08-01

    Heparin is one of the most frequently used anticoagulants. It is easy to use, but can be associated with life-threatening side effects. One of these is heparin-induced thrombocytopenia syndrome (HITS), which develops in about 3-5% of patients exposed to heparin and is associated with thrombosis in 1% of cases. We report here the successful treatment of five patients with HITS who were treated with alternative anticoagulants namely danaparoid or hirudin. The median time between their exposure to heparin and onset of symptoms and or signs was 10.2 days (range 7-14 days). Platelet counts decreased to a mean of 38.4 x 10(9) \\/l (12-82 x 10(9)\\/l). All five patients had evidence of thrombosis; four patients had clinical and radiological evidence of pulmonary emboli, one patient had confirmed deep vein thrombosis (DVT) and one patient had extensive skin necrosis of the thighs and abdomen. Platelet aggregation test were positive in two patients, inconclusive in one patient and negative in two patients. Two patients were anticoagulated with danaparoid and three with hirudin until their platelet counts returned to normal between 4 and 14 days (average 6 days) following the recognition of the syndrome. Our patients had significant morbidity, but no mortality. Immediate withdrawal of heparin is of paramount importance and introduction of alternative anticoagulant is necessary in the presence of thrombosis.

  17. Dosagem da heparina em cirurgia cardíaca com circulação extracorpórea Measurement of heparin in cardiac surgery wilh extracorporea circulation

    Directory of Open Access Journals (Sweden)

    Fernando Moraes

    1996-09-01

    Full Text Available Com o objetivo de quantificar o nível sérico de heparina, sua atenuação em função do tempo e o valor residual após a neutralização com sulfato de protamina, foram coletadas amostras de sangue em tempos pré-estabelecidos em 27 pacientes submetidos a revascularização do miocárdio com circulação extracorpórea. Após a heparinização (400 Ul/kg as amostras de sangue foram coletadas nos tempos de 5, 10,30 e 60 minutos e subseqüentemente a cada 30 minutos, dependendo do tempo da circulação extracorpórea. A cada hora, após a heparinização, administrava-se nova dose de heparina (200 Ul/kg. As amostras eram armazenadas à temperatura de 4ºC antes do processo de extração da heparina que foi realizado por métodos físico-químicos. As dosagens mostraram que 5 minutos após a heparinização os pacientes apresentaram concentração sangüínea máxima de heparina e, ao tempo de 60 minutos, a sua concentração é de aproximadamente 68% da encontrada aos 5 minutos. Ao tempo de 90 minutos, ou seja, após a reheparinização a concentração de heparina é 96% da evidenciada aos cinco minutos e, após a neutralização com sulfato de protamina (1,5:1, ainda se encontra um valor residual de heparina que corresponde a 4% do observado inicialmente. Observou-se que os pacientes mais idosos têm uma tendência a manter um nível sérico mais prolongado e através da equação (Cone. de heparina = 104,7 + (- 12,85 x minutos (In + 0,25 x idade podemos estimar a concentração de heparina em determinado tempo.In order to quantify seric levels of heparin, its attenuation as a time function and its residual value after neutralization with protamine sulfate, blood samples were collected, at pre-set intervals, from 27 patients undergoing myocardial revascularization surgery under extracorporeal circulation. After heparinization (400 Ul/Kg, blood samples were collected at 5, 10, 30 and 60 minutes and subsequently every 30 minutes depending upon

  18. Blood interaction with a Bioline heparin coated HIA-VAD : A study on calves

    NARCIS (Netherlands)

    vanderKamp, KWHJ; Magielse, CPE; Elstrodt, JM; vanderMeer, J; vanOeveren, W; Rakhorst, G

    The blood compatibility of ventricular assist devices developed by the Helmholtz institute Aachen (HA-VAD's) was tested on calves. Seven calves received a non-coated HIA-VAD (control) and three a Bioline heparin coated device. The circulatory support of these HIA-VAD's lasted one week. Mechanical

  19. Extrapulmonary colony formation after intravenous injection of tumour cells into heparin treated animals

    NARCIS (Netherlands)

    Maat, B.

    1978-01-01

    Recent data on extrapulmonary colony formation after heparin administration are inconclusive. A systemic study of this topic was undertaken with 4 experimental tumour systems and 2 distinct periods of reduced clotting capacity in rats and mice. I.v. injection of various numbers of tumour cells into

  20. Heparin free coating on PLA membranes for enhanced hemocompatibility via iCVD

    Science.gov (United States)

    Wang, Hui; Shi, Xiao; Gao, Ailin; Lin, Haibo; Chen, Yongliang; Ye, Yumin; He, Jidong; Liu, Fu; Deng, Gang

    2018-03-01

    In the present work, we report one-step immobilization of nano-heparin coating on PLA membranes via initiated chemical vapor deposition (iCVD) for enhanced hemocompatibility. The nano-coating introduced onto the membrane surface via the crosslinking of P(MAA-EGDA) was confirmed by the FTIR, SEM and weight measurement respectively. The negative carboxyl groups could form the hydration interaction with the protein and platelets and electrostatic interaction with amide groups of thrombin by the mediation of antithrombin, which is similar but different with heparin. The P(MAA-EGDA) coated membranes showed suppressed platelet adhesion and prolonged clotting time (APTTs increased to 59 s, PTs increased to 20.4 s, TTs increased to 17.5 s, and the FIBs declined by 30 mg/dL). Moreover, the complement activation tests demonstrated the formation of C3a and C5a was inhibited. All results demonstrated that the nano-coating of P(MAA-EGDA) via iCVD significantly enhanced the hemocompatibility of PLA membranes, which is also applicable for various membranes.

  1. Comparison of Efficacy Compressive Stockings with Heparin in Prevention of Deep Vein Thrombosis in Stroke Patients

    Directory of Open Access Journals (Sweden)

    Nastaran Majdi-Nasab

    2013-04-01

    Full Text Available Background: The present study is carried out to make a comparison between two pharmacological (heparin and physical (compression stockings in the prevention of deep vein thrombosis in lower limb of the patients suffered from acute stroke. Materials and Methods: In this investigation as a clinical trial, the effectiveness of the above methods on 100 patients with the stroke was compared in two groups of 50 persons. Results: Three patients in physical group and two patients in pharmacological group got deep vein thrombosis that showed no significant difference between two groups.Conclusion: In spite of no significant relationship and due to less incurrence of thrombosis in heparin group, it is more reasonable to use pharmacological methods.

  2. [Obstetrical APS: Is there a place for additional treatment to aspirin-heparin combination?

    Science.gov (United States)

    Mekinian, A; Kayem, G; Cohen, J; Carbillon, L; Abisror, N; Josselin-Mahr, L; Bornes, M; Fain, O

    2017-01-01

    Obstetrical APS is defined by thrombosis and/or obstetrical morbidity associated with persistent antiphospholipid antibodies. The aspirin and low molecular weighted heparin combination dramatically improved obstetrical outcome in APS patients. Several factors could be associated with obstetrical prognosis, as previous history of thrombosis, associated SLE, the presence of lupus anticoagulant and triple positivity of antiphospholipid antibodies. Obstetrical APS with isolated recurrent miscarriages is mostly associated with isolated anticardiolipids antibodies and have better obstetrical outcome. The pregnancy loss despite aspirin and heparin combination define the refractory obstetrical APS, and the prevalence could be estimated to 20-39%. Several other treatments have been used in small and open labeled studies, as steroids, intravenous immunoglobulins, plasma exchanges and hydroxychloroquine to improve the obstetrical outcome. Some other drugs as eculizumab and statins could also have physiopathological rational, but studies are necessary to define the place of these various drugs. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  3. Network reconfiguration for loss reduction in electrical distribution system using genetic algorithm

    International Nuclear Information System (INIS)

    Adail, A.S.A.A.

    2012-01-01

    Distribution system is a critical links between the utility and the nuclear installation. During feeding electricity to that installation there are power losses. The quality of the network depends on the reduction of these losses. Distribution system which feeds the nuclear installation must have a higher quality power. For example, in Inshas site, electrical power is supplied to it from two incoming feeders (one from new abu-zabal substation and the other from old abu-zabal substation). Each feeder is designed to carry the full load, while the operator preferred to connect with a new abu-zabal substation, which has a good power quality. Bad power quality affects directly the nuclear reactor and has a negative impact on the installed sensitive equipment's of the operation. The thesis is Studying the electrical losses in a distribution system (causes and effected factors), feeder reconfiguration methods, and applying of genetic algorithm in an electric distribution power system. In the end, this study proposes an optimization technique based on genetic algorithms for distribution network reconfiguration to reduce the network losses to minimum. The proposed method is applied to IEEE test network; that contain 3 feeders and 16 nodes. The technique is applied through two groups, distribution have general loads, and nuclear loads. In the groups the technique applied to seven cases at normal operation state, system fault condition as well as different loads conditions. Simulated results are drawn to show the accuracy of the technique.

  4. An algorithm for reduction of extracted power from photovoltaic strings in grid-tied photovoltaic power plants during voltage sags

    DEFF Research Database (Denmark)

    Tafti, Hossein Dehghani; Maswood, Ali Iftekhar; Pou, Josep

    2016-01-01

    strings should be reduced during voltage sags. In this paper, an algorithm is proposed for determining the reference voltage of the PV string which results in a reduction of the output power to a certain amount. The proposed algorithm calculates the reference voltage for the dc/dc converter controller......, based on the characteristics of the power-voltage curve of the PV string and therefore, no modification is required in the the controller of the dc/dc converter. Simulation results on a 50-kW PV string verified the effectiveness of the proposed algorithm in reducing the power from PV strings under......Due to the high penetration of the installed distributed generation units in the power system, the injection of reactive power is required for the medium-scale and large-scale grid-connected photovoltaic power plants (PVPPs). Because of the current limitation of the grid-connected inverter...

  5. The use of anatomical information for molecular image reconstruction algorithms: Attention/Scatter correction, motion compensation, and noise reduction

    Energy Technology Data Exchange (ETDEWEB)

    Chun, Se Young [School of Electrical and Computer Engineering, Ulsan National Institute of Science and Technology (UNIST), Ulsan (Korea, Republic of)

    2016-03-15

    PET and SPECT are important tools for providing valuable molecular information about patients to clinicians. Advances in nuclear medicine hardware technologies and statistical image reconstruction algorithms enabled significantly improved image quality. Sequentially or simultaneously acquired anatomical images such as CT and MRI from hybrid scanners are also important ingredients for improving the image quality of PET or SPECT further. High-quality anatomical information has been used and investigated for attenuation and scatter corrections, motion compensation, and noise reduction via post-reconstruction filtering and regularization in inverse problems. In this article, we will review works using anatomical information for molecular image reconstruction algorithms for better image quality by describing mathematical models, discussing sources of anatomical information for different cases, and showing some examples.

  6. Finding optimal exact reducts

    KAUST Repository

    AbouEisha, Hassan M.

    2014-01-01

    The problem of attribute reduction is an important problem related to feature selection and knowledge discovery. The problem of finding reducts with minimum cardinality is NP-hard. This paper suggests a new algorithm for finding exact reducts

  7. Gene expression of cyclin-dependent kinase inhibitors and effect of heparin on their expression in mice with hypoxia-induced pulmonary hypertension

    International Nuclear Information System (INIS)

    Yu Lunyin; Quinn, Deborah A.; Garg, Hari G.; Hales, Charles A.

    2006-01-01

    The balance between cell proliferation and cell quiescence is regulated delicately by a variety of mediators, in which cyclin-dependent kinases (CDK) and CDK inhibitors (CDKI) play a very important role. Heparin which inhibits pulmonary artery smooth muscle cell (PASMC) proliferation increases the levels of two CDKIs, p21 and p27, although only p27 is important in inhibition of PASMC growth in vitro and in vivo. In the present study we investigated the expression profile of all the cell cycle regulating genes, including all seven CDKIs (p21, p27, p57, p15, p16, p18, and p19), in the lungs of mice with hypoxia-induced pulmonary hypertension. A cell cycle pathway specific gene microarray was used to profile the 96 genes involved in cell cycle regulation. We also observed the effect of heparin on gene expression. We found that (a) hypoxic exposure for two weeks significantly inhibited p27 expression and stimulated p18 activity, showing a 98% decrease in p27 and 81% increase in p18; (b) other CDKIs, p21, p57, p15, p16, and p19 were not affected significantly in response to hypoxia; (c) heparin treatment restored p27 expression, but did not influence p18; (d) ERK1/2 and p38 were mediators in heparin upregulation of p27. This study provides an expression profile of cell cycle regulating genes under hypoxia in mice with hypoxia-induced pulmonary hypertension and strengthens the previous finding that p27 is the only CDKI involved in heparin regulation of PASMC proliferation and hypoxia-induced pulmonary hypertension

  8. Multiphase flows of N immiscible incompressible fluids: A reduction-consistent and thermodynamically-consistent formulation and associated algorithm

    Science.gov (United States)

    Dong, S.

    2018-05-01

    We present a reduction-consistent and thermodynamically consistent formulation and an associated numerical algorithm for simulating the dynamics of an isothermal mixture consisting of N (N ⩾ 2) immiscible incompressible fluids with different physical properties (densities, viscosities, and pair-wise surface tensions). By reduction consistency we refer to the property that if only a set of M (1 ⩽ M ⩽ N - 1) fluids are present in the system then the N-phase governing equations and boundary conditions will exactly reduce to those for the corresponding M-phase system. By thermodynamic consistency we refer to the property that the formulation honors the thermodynamic principles. Our N-phase formulation is developed based on a more general method that allows for the systematic construction of reduction-consistent formulations, and the method suggests the existence of many possible forms of reduction-consistent and thermodynamically consistent N-phase formulations. Extensive numerical experiments have been presented for flow problems involving multiple fluid components and large density ratios and large viscosity ratios, and the simulation results are compared with the physical theories or the available physical solutions. The comparisons demonstrate that our method produces physically accurate results for this class of problems.

  9. Low molecular weight heparins in the prevention of deep-vein thrombosis in general surgery.

    Science.gov (United States)

    Breddin, H K

    1999-01-01

    Unfractionated heparin (UFH) was the established treatment in the early 1980s for the prophylaxis of venous thromboembolic disease (VTED) in patients undergoing general surgery. This was one of the earliest indications in which low molecular weight heparins (LMWHs) were tested, and about 40 trials have revealed that these agents are at least as effective and safe as UFH with a tendency of superiority when higher dosages are used. In most trials, the fibrinogen uptake test has been used to assess the frequency of deep vein thrombosis. LMWHs exhibit a number of improved features over UFH, including ease of administration and convenient once daily dosing, facilitating outpatient management. A still open question is the ideal time and dose of the first one or two injections of a LMWH. To determine the clinical relevance of product differentiation further, clinical trials, directly comparing different LMWHs, are required.

  10. Comparing the ISO-recommended and the cumulative data-reduction algorithms in S-on-1 laser damage test by a reverse approach method

    Science.gov (United States)

    Zorila, Alexandru; Stratan, Aurel; Nemes, George

    2018-01-01

    We compare the ISO-recommended (the standard) data-reduction algorithm used to determine the surface laser-induced damage threshold of optical materials by the S-on-1 test with two newly suggested algorithms, both named "cumulative" algorithms/methods, a regular one and a limit-case one, intended to perform in some respects better than the standard one. To avoid additional errors due to real experiments, a simulated test is performed, named the reverse approach. This approach simulates the real damage experiments, by generating artificial test-data of damaged and non-damaged sites, based on an assumed, known damage threshold fluence of the target and on a given probability distribution function to induce the damage. In this work, a database of 12 sets of test-data containing both damaged and non-damaged sites was generated by using four different reverse techniques and by assuming three specific damage probability distribution functions. The same value for the threshold fluence was assumed, and a Gaussian fluence distribution on each irradiated site was considered, as usual for the S-on-1 test. Each of the test-data was independently processed by the standard and by the two cumulative data-reduction algorithms, the resulting fitted probability distributions were compared with the initially assumed probability distribution functions, and the quantities used to compare these algorithms were determined. These quantities characterize the accuracy and the precision in determining the damage threshold and the goodness of fit of the damage probability curves. The results indicate that the accuracy in determining the absolute damage threshold is best for the ISO-recommended method, the precision is best for the limit-case of the cumulative method, and the goodness of fit estimator (adjusted R-squared) is almost the same for all three algorithms.

  11. Amperometric Sensor for Heparin: Sensing Mechanism and Application in Human Blood Plasma Analysis

    Czech Academy of Sciences Publication Activity Database

    Langmaier, Jan; Olšák, J.; Samcová, E.; Samec, Zdeněk; Trojánek, Antonín

    2006-01-01

    Roč. 18, 13-14 (2006), s. 1329-1338 ISSN 1040-0397 R&D Projects: GA ČR GA203/04/0424 Institutional research plan: CEZ:AV0Z40400503 Keywords : heparin * amperometry * PVC membrane electrode * sensing mechanism * human blood plasma Subject RIV: CG - Electrochemistry Impact factor: 2.444, year: 2006

  12. Decoding Interleaved Gabidulin Codes using Alekhnovich's Algorithm

    DEFF Research Database (Denmark)

    Puchinger, Sven; Müelich, Sven; Mödinger, David

    2017-01-01

    We prove that Alekhnovich's algorithm can be used for row reduction of skew polynomial matrices. This yields an O(ℓ3n(ω+1)/2log⁡(n)) decoding algorithm for ℓ-Interleaved Gabidulin codes of length n, where ω is the matrix multiplication exponent.......We prove that Alekhnovich's algorithm can be used for row reduction of skew polynomial matrices. This yields an O(ℓ3n(ω+1)/2log⁡(n)) decoding algorithm for ℓ-Interleaved Gabidulin codes of length n, where ω is the matrix multiplication exponent....

  13. Radioiodine therapy of hyperfunctioning thyroid nodules: usefulness of an implemented dose calculation algorithm allowing reduction of radioiodine amount.

    Science.gov (United States)

    Schiavo, M; Bagnara, M C; Pomposelli, E; Altrinetti, V; Calamia, I; Camerieri, L; Giusti, M; Pesce, G; Reitano, C; Bagnasco, M; Caputo, M

    2013-09-01

    Radioiodine is a common option for treatment of hyperfunctioning thyroid nodules. Due to the expected selective radioiodine uptake by adenoma, relatively high "fixed" activities are often used. Alternatively, the activity is individually calculated upon the prescription of a fixed value of target absorbed dose. We evaluated the use of an algorithm for personalized radioiodine activity calculation, which allows as a rule the administration of lower radioiodine activities. Seventy-five patients with single hyperfunctioning thyroid nodule eligible for 131I treatment were studied. The activities of 131I to be administered were estimated by the method described by Traino et al. and developed for Graves'disease, assuming selective and homogeneous 131I uptake by adenoma. The method takes into account 131I uptake and its effective half-life, target (adenoma) volume and its expected volume reduction during treatment. A comparison with the activities calculated by other dosimetric protocols, and the "fixed" activity method was performed. 131I uptake was measured by external counting, thyroid nodule volume by ultrasonography, thyroid hormones and TSH by ELISA. Remission of hyperthyroidism was observed in all but one patient; volume reduction of adenoma was closely similar to that assumed by our model. Effective half-life was highly variable in different patients, and critically affected dose calculation. The administered activities were clearly lower with respect to "fixed" activities and other protocols' prescription. The proposed algorithm proved to be effective also for single hyperfunctioning thyroid nodule treatment and allowed a significant reduction of administered 131I activities, without loss of clinical efficacy.

  14. Naked eye detection of infertility based on sperm protamine-induced aggregation of heparin gold nanoparticles.

    Science.gov (United States)

    Vidya, Raj; Saji, Alex

    2018-05-01

    The development of an easy to use, one-pot, environmentally friendly, non-invasive and label-free colorimetric probe for the determination of semen protamines, the biochemical marker of male fertility, using heparin gold nanoparticles (HAuNPs) is presented. The affinity of HAuNPs for protamines was due to the electrostatic interactions between polycationic protamine and polyanionic heparin. The binding of HAuNPs to protamine was characterized by variation in the plasmon absorption spectra followed by a visibly observable colour change of the solution from red to blue. We observed a red shift in the plasmon peak and the method exhibited linearity in the range of 10-70 ng/mL with a detection limit of 5 ng/mL, which is much lower than that reported for colorimetric sensors of protamine. The colour change and the variation in the absorbance of HAuNPs were highly specific for protamines in the presence of different interfering compounds and the method was successfully applied for determining protamine in real samples of semen and serum. Rather than a quantitative estimation, it seems that the method provides a quick screening between a large array of positive and negative samples and, moreover, it maintains the privacy of the user. The method appears to be simple and would be very useful in third-world countries where high-tech diagnostic aids are inaccessible to the majority of the population. Graphical Abstract Heparin gold nanoparticles aided visual detection of infertility.

  15. Sensitive and selective turn off-on fluorescence detection of heparin based on the energy transfer platform using the BSA-stabilized Au nanoclusters/amino-functionalized graphene oxide hybrids.

    Science.gov (United States)

    Lan, Jing; Zou, Hong Yan; Wang, Qiang; Zeng, Ping; Li, Yuan Fang; Huang, Cheng Zhi

    2016-12-01

    An ultra-sensitive and selective turn off-on fluorescence detection of heparin based on the energy transfer in the BSA-stabilized gold nanoclusters/amino-functionalized graphene oxide (BSA-AuNCs/NH 2 -GO) hybrids was successfully realized. The BSA-AuNCs containing amounts of carboxyl groups could be absorbed on the surface of NH 2 -GO through the electrostatic interaction, which resulted in the fluorescence quenching of BSA-AuNCs with high efficiency. However, heparin, possessing high density of negative charge, could compete with BSA-AuNCs to bind NH 2 -GO and block the energy transfer from BSA-AuNCs to NH 2 -GO. The fluorescence recovery of BSA-AuNCs was closely related to the amount of heparin and there was a good linear relationship between fluorescence recovery of BSA-AuNCs and heparin over the range of 100ng/mL to 30μg/mL with a detection limit of 40ng/mL. What's more, the fluorescence assay was successfully applied for heparin sensing in human serums and intracellular imaging. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Increased synthesis of heparin affin regulatory peptide in the perforant path lesioned mouse hippocampal formation

    DEFF Research Database (Denmark)

    Poulsen, F R; Lagord, C; Courty, J

    2000-01-01

    Heparin affin regulatory peptide (HARP), also known as pleiotrophin or heparin-binding growth-associated molecule, is a developmentally regulated extracellular matrix protein that induces cell proliferation and promotes neurite outgrowth in vitro as well as pre- and postsynaptic developmental...... differentiation in vivo. Here we have investigated the expression of HARP mRNA and protein in the perforant path lesioned C57B1/6 mouse hippocampal formation from 1 to 35 days after surgery. This type of lesion induces a dense anterograde and terminal axonal degeneration, activation of glial cells, and reactive...... axonal sprouting within the perforant path zones of the fascia dentata and hippocampus as well as axotomy-induced retrograde neuronal degeneration in the entorhinal cortex. Analysis of sham- and unoperated control mice showed that HARP mRNA is expressed in neurons and white and gray matter glial cells...

  17. Geometric approximation algorithms

    CERN Document Server

    Har-Peled, Sariel

    2011-01-01

    Exact algorithms for dealing with geometric objects are complicated, hard to implement in practice, and slow. Over the last 20 years a theory of geometric approximation algorithms has emerged. These algorithms tend to be simple, fast, and more robust than their exact counterparts. This book is the first to cover geometric approximation algorithms in detail. In addition, more traditional computational geometry techniques that are widely used in developing such algorithms, like sampling, linear programming, etc., are also surveyed. Other topics covered include approximate nearest-neighbor search, shape approximation, coresets, dimension reduction, and embeddings. The topics covered are relatively independent and are supplemented by exercises. Close to 200 color figures are included in the text to illustrate proofs and ideas.

  18. Network Reduction Algorithm for Developing Distribution Feeders for Real-Time Simulators: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Nagarajan, Adarsh; Nelson, Austin; Prabakar, Kumaraguru; Hoke, Andy; Asano, Marc; Ueda, Reid; Nepal, Shaili

    2017-06-15

    As advanced grid-support functions (AGF) become more widely used in grid-connected photovoltaic (PV) inverters, utilities are increasingly interested in their impacts when implemented in the field. These effects can be understood by modeling feeders in real-time systems and testing PV inverters using power hardware-in-the-loop (PHIL) techniques. This paper presents a novel feeder model reduction algorithm using a Monte Carlo method that enables large feeders to be solved and operated on real-time computing platforms. Two Hawaiian Electric feeder models in Synergi Electric's load flow software were converted to reduced order models in OpenDSS, and subsequently implemented in the OPAL-RT real-time digital testing platform. Smart PV inverters were added to the real-time model with AGF responses modeled after characterizing commercially available hardware inverters. Finally, hardware inverters were tested in conjunction with the real-time model using PHIL techniques so that the effects of AGFs on the choice feeders could be analyzed.

  19. Thrombolytic treatment for acute ischemic cerebral stroke: intraarterial urokinase infusion vs. intravenous heparin and urokinase infusion

    International Nuclear Information System (INIS)

    Ko, Gi Young; Suh, Dae Chul; Lee, Jae Hong; Kim, Jun Hyoung; Choi, Choong Gon; Lee, Ho Kyu; Lee, Myoung Chong

    1996-01-01

    To evaluate the efficacy and limitation of intra-arterial urokinase (IAUK) infusion for treatment of acute cerebral stroke. Twenty-seven acute cerebral stroke patients treated with IAUK infusion within six hours of stroke onset were reviewed. All patients showed normal initial brain findings on CT. In 21 patients, urokinase(5-15 x 10 5 IU) was administered through a microcatheter placed into or proximal to occluded segment. Mechanical disruption of thrombus by guidewire was performed in 17 patients. Angiographic and clinical responses and complications after IAUK infusion, were evaluated and the results were compared with those of intravenous heparin(N=19) and urokinase infusion(N=19). Complete or partial angiographic recanalization of occluded segment was found in 18 patients (67%), and neurologic improvement was followed in 14 patients(52%). The degree of improvement on the stroke scale score after IAUK infusion was statistically more significant(p<0.05) than that shown after intravenous heparin and urokinase infusion. Complications after IAUK infusion were large(15%) and small amount intracerebral hemorrhage(15%), contrast leakage into brain parenchyma(11%), and gastrointestinal bleeding(4%). Between the IAVK and the intravenous urokinase infusion group, differences in extent and types of complications were statistically insignificant, but were significantly higher in those two groups than in the intravenous heparin infusion group. IAUK infusion may be effective for the treatment of acute cerebral stroke

  20. Comparison of the therapeutic effects of sildenafil citrate, heparin and neuropeptides in a rat model of acetic acid-induced gastric ulcer.

    Science.gov (United States)

    Kalayci, Mehmet; Kocdor, Mehmet Ali; Kuloglu, Tuncay; Sahin, İbrahim; Sarac, Mehmet; Aksoy, Aziz; Yardim, Meltem; Dalkilic, Semih; Gursu, Onur; Aydin, Suna; Akkoc, Ramazan Fazil; Ugras, Meltem; Artas, Gokhan; Ozercan, İbrahim Hanifi; Ugur, Kader; Aydin, Suleyman

    2017-10-01

    The purpose of our investigative work has been to determine whether there can be therapeutic roles in the administration of sildenafil citrate, heparin and several neuropeptides on an animal model where gastric ulcers were induced with acetic acid, and to compare their efficacy. The animals were divided into 13 groups, with 4 animals in each. Gastric ulcers was induced in the animals of 12 groups with one untreated group being left as the control (Group I - control; given normal saline (NS)). The other groups were: Group II (ulcer+NS); Group III (5mg/kg sildenafil citrate, low dose); Group IV (10mg/kg sildenafil citrate, high dose); Group V (0.6mg/kg heparin, low dose); Group VI (6mg/kg heparin, high dose); Group VII (20nmol/kg des-acyl ghrelin); Group VIII (40nmol/kg des-acyl ghrelin); Group IX (4nmol/kg acyl ghrelin); Group X (8nmol/kg acly ghrelin); Group XI (20pmol/kg Nesfatin-1); Group XII (15nmol/kg Obestatin) and Group XIII (5nmol/kg Neuropeptide Y). Gastric neuropeptide expression was measured using an immunohistochemical method, and the amount in circulation was detected using ELISA. To compare with no treatment, the controls and other treatment groups, we recorded loss of the surface epithelium of the stomach, erosion, bleeding and inflammatory cell infiltration in the upper halves of the gastric glands. The muscularis and the layers beneath it were, however, apparently normal. The gastric mucosa healed with little or no inflammation when sildenafil citrate, low dose heparin, ghrelin, NUCB2/Nesfatin-1, obestatin, Neuropeptide Y were administered. Overall the data indicate that low dose heparin, and especially sildenafil citrate and neuropeptides, can be used clinically as an alternative approach in the treatment of the gastric ulcer. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Effect of low-dose heparin on urinary albumin excretion in insulin-dependent diabetes mellitus

    DEFF Research Database (Denmark)

    Myrup, B; Hansen, P M; Jensen, T

    1995-01-01

    We investigated the effect of heparin on urinary albumin excretion in patients with insulin-dependent diabetes mellitus. 39 patients with persistent urinary albumin excretion of 30-300 mg/24 h were randomly treated for 3 months with subcutaneous injections twice daily of isotonic saline, 5000 IU...

  2. Effect of low-dose heparin on urinary albumin excretion in insulin-dependent diabetes mellitus

    NARCIS (Netherlands)

    Myrup, B.; Hansen, P.M.; Jensen, T.; Kofoed-Enevoldsen, A.; Feldt-Rasmussen, B.; Gram, J.; Kluft, C.; Jespersen, J.; Deckert, T.

    1995-01-01

    We investigated the effect of heparin on urinary albumin excretion in patients with insulin-dependent diabetes mellitus. 39 patients with persistent urinary albumin excretion of 30-300 mg/24 h were randomly treated for 3 months with subcutaneous injections twice daily of isotonic saline, 5000 IU

  3. Use of low molecular weight Heparin for Hemodialysis: A short term study

    International Nuclear Information System (INIS)

    Al-Arrayed, S.; Seshadri, R.

    2002-01-01

    Although unfractionated heparin (UFH) is the anticoagulant commonly usedfor Hemodialysis (HD), low molecular weight heparin (LMWH) has been found tobe equally efficacious. The aim of this study was to explore the safety andefficacy of a single bolus dose of the LMWH, enoxaparin. Thirty-eightpatients on maintenance HD were randomly divided into two equal groups. Themean age and body-weight of the two were comparable. While one group received1 mg/kg body-weight (the manufacturer's recommended dose) of enoxaparin forthree dialysis sessions of three-hour duration each, the either groupreceived a fixed dose of 40 mg for the same number of dialysis. For the nextthree dialysis sessions, these doses were exchanged between the groups. Inall, total of 228 HD sessions were monitored for clotting of bloodlines/dialyzers and bleeding from vascular access and other sites. The rateof complications was compared with the historical data while UFH was beingused for the same patients. In general, enoxapirin was associated with fewerepisodes of bleeding and clotting. Our study confirms that LMWH is ofcomparable efficacy to UFH and probably a lesser than recommended dose isadequate for three-hour HD session. (author)

  4. Centrifugation protocols: tests to determine optimal lithium heparin and citrate plasma sample quality.

    Science.gov (United States)

    Dimeski, Goce; Solano, Connie; Petroff, Mark K; Hynd, Matthew

    2011-05-01

    Currently, no clear guidelines exist for the most appropriate tests to determine sample quality from centrifugation protocols for plasma sample types with both lithium heparin in gel barrier tubes for biochemistry testing and citrate tubes for coagulation testing. Blood was collected from 14 participants in four lithium heparin and one serum tube with gel barrier. The plasma tubes were centrifuged at four different centrifuge settings and analysed for potassium (K(+)), lactate dehydrogenase (LD), glucose and phosphorus (Pi) at zero time, poststorage at six hours at 21 °C and six days at 2-8°C. At the same time, three citrate tubes were collected and centrifuged at three different centrifuge settings and analysed immediately for prothrombin time/international normalized ratio, activated partial thromboplastin time, derived fibrinogen and surface-activated clotting time (SACT). The biochemistry analytes indicate plasma is less stable than serum. Plasma sample quality is higher with longer centrifugation time, and much higher g force. Blood cells present in the plasma lyse with time or are damaged when transferred in the reaction vessels, causing an increase in the K(+), LD and Pi above outlined limits. The cells remain active and consume glucose even in cold storage. The SACT is the only coagulation parameter that was affected by platelets >10 × 10(9)/L in the citrate plasma. In addition to the platelet count, a limited but sensitive number of assays (K(+), LD, glucose and Pi for biochemistry, and SACT for coagulation) can be used to determine appropriate centrifuge settings to consistently obtain the highest quality lithium heparin and citrate plasma samples. The findings will aid laboratories to balance the need to provide the most accurate results in the best turnaround time.

  5. Use of prestudy heparin did not influence the efficacy and safety of rivaroxaban in patients treated for symptomatic venous thromboem-bolism in the EINSTEIN DVT and EINSTEIN PE studies.

    Science.gov (United States)

    Prandoni, Paolo; Prins, Martin H; Cohen, Alexander T; Müller, Katharina; Pap, Ákos F; Tewes, Miriam C; Lensing, Anthonie W A

    2015-02-01

    In the EINSTEIN DVT and EINSTEIN PE studies, the majority of patients received heparins to bridge the period during venous thromboembolism (VTE) diagnosis confirmation and the start of the study. In contrast to vitamin K antagonists (VKAs), rivaroxaban may not require initial heparin treatment. To evaluate the effect of prestudy heparin on the efficacy and safety of rivaroxaban relative to enoxaparin/VKA, the 3-month incidence of recurrent VTE, and the 14-day incidence of major and nonmajor clinically relevant bleeding were compared in patients who did and did not receive prestudy heparin. Of the 8,281 patients randomized, 6,937 (83.8%) received prestudy heparin (mean ± SD duration = rivaroxaban: 1.04 [± 0.74] days; enoxaparin 1.03 [± 0.42] days), and 1,344 (16.2%) did not. In patients who did not receive prestudy heparin, the incidences of recurrent VTE were similar in rivaroxaban (15 of 649, 2.3%) and enoxaparin/VKA (13 of 695, 1.9%) patients (adjusted hazard ratio [HR] = 1.11; 95% confidence interval [CI] = 0.52 to 2.37). The incidences of recurrent VTE were also similar in rivaroxaban (54 of 3,501, 1.5%) and enoxaparin/VKA (69 of 3,436, 2.0%) patients who did receive prestudy heparin (adjusted HR = 0.74; 95% CI = 0.52 to 1.06; pinteraction  = 0.32). The incidences of major or nonmajor clinically relevant bleeding with rivaroxaban were not significantly different from those with enoxaparin/VKA, either with (105 of 3,485, 3.0% vs. 104 of 3,428, 3.0%; adjusted HR = 0.98; 95% CI = 0.75 to 1.29) or without (24 of 645, 3.7% vs. 30 of 688, 4.4%; adjusted HR = 0.81; 95% CI = 0.46 to 1.40; pinteraction  = 0.68) prestudy heparin. Although the majority of patients in the EINSTEIN studies received prestudy heparin, there were no notable differences in treatment effect of rivaroxaban versus enoxaparin/VKA in those who did and did not receive it. © 2015 by the Society for Academic Emergency Medicine.

  6. Isolation of non-heprin-binding and heparin-binding proteins of boar prostate

    Czech Academy of Sciences Publication Activity Database

    Maňásková, Pavla; Liberda, J.; Tichá, M.; Jonáková, Věra

    2002-01-01

    Roč. 770, - (2002), s. 137-143 ISSN 1570-0232. [International Symposium /2./ - Separation in the BioSciences. Praha, 17.09.2001-20.09.2001] R&D Projects: GA ČR GA303/99/0357; GA ČR GV524/96/K162 Institutional research plan: CEZ:AV0Z5052915 Keywords : isolation * prostatic proteins * heparin Subject RIV: CE - Biochemistry Impact factor: 1.913, year: 2002

  7. Aggregated forms of bull seminal plasma proteins and their heparin-binding activity

    Czech Academy of Sciences Publication Activity Database

    Jelínková, Petra; Ryšlavá, H.; Liberda, J.; Jonáková, Věra; Tichá, M.

    2004-01-01

    Roč. 69, - (2004), s. 616-630 ISSN 0010-0765 R&D Projects: GA ČR GA303/02/0433; GA ČR GP303/02/P069; GA MZd NJ7463 Institutional research plan: CEZ:AV0Z5052915; CEZ:MSM 113100001 Keywords : bull seminal plasma proteins * heparin-binding proteins * aggregated forms of proteins Subject RIV: CE - Biochemistry Impact factor: 1.062, year: 2004

  8. Magnet sorting algorithms

    International Nuclear Information System (INIS)

    Dinev, D.

    1996-01-01

    Several new algorithms for sorting of dipole and/or quadrupole magnets in synchrotrons and storage rings are described. The algorithms make use of a combinatorial approach to the problem and belong to the class of random search algorithms. They use an appropriate metrization of the state space. The phase-space distortion (smear) is used as a goal function. Computational experiments for the case of the JINR-Dubna superconducting heavy ion synchrotron NUCLOTRON have shown a significant reduction of the phase-space distortion after the magnet sorting. (orig.)

  9. Heparin-bonded, expanded polytetrafluoroethylene-lined stent graft in the treatment of femoropopliteal artery disease: 1-year results of the VIPER (Viabahn Endoprosthesis with Heparin Bioactive Surface in the Treatment of Superficial Femoral Artery Obstructive Disease) trial.

    Science.gov (United States)

    Saxon, Richard R; Chervu, Arun; Jones, Paul A; Bajwa, Tanvir K; Gable, Dennis R; Soukas, Peter A; Begg, Richard J; Adams, John G; Ansel, Gary M; Schneider, Darren B; Eichler, Charles M; Rush, Michael J

    2013-02-01

    To evaluate the performance of a heparin-bonded, expanded polytetrafluoroethylene (ePTFE)-lined nitinol endoprosthesis in the treatment of long-segment occlusive disease of the femoropopliteal artery (FPA) and to identify factors associated with loss of patency. In a single-arm, prospective, 11-center study (VIPER [Gore Viabahn Endoprosthesis with Heparin Bioactive Surface in the Treatment of Superficial Femoral Artery Obstructive Disease] trial), 119 limbs (113 patients; 69 men; mean age, 67 y), including 88 with Rutherford category 3-5 disease and 72 with Inter-Society Consensus for the Management of Peripheral Arterial Disease (TASC II) C or D lesions of the FPA, underwent stent graft implantation. The mean lesion length was 19 cm; 56% of lesions were occlusions. Follow-up evaluations included color duplex ultrasonography in all patients, with patency defined as a peak systolic velocity ratio20% was 70% (P = .047). Primary patency was not significantly affected by device diameter (5 vs 6 vs 7 mm) or lesion length (≤20 cm vs>20 cm). The 30-day major adverse event rate was 0.8%. The heparin-bonded, ePTFE/nitinol stent graft provided clinical improvement and a primary patency rate of 73% at 1 year in the treatment of long-segment FPA disease. Careful sizing of the device relative to vessel landing zones is essential for achieving optimal outcomes. Copyright © 2013 SIR. Published by Elsevier Inc. All rights reserved.

  10. Enhancement of trophoblast differentiation and survival by low molecular weight heparin requires heparin-binding EGF-like growth factor.

    Science.gov (United States)

    Bolnick, Alan D; Bolnick, Jay M; Kohan-Ghadr, Hamid-Reza; Kilburn, Brian A; Pasalodos, Omar J; Singhal, Pankaj K; Dai, Jing; Diamond, Michael P; Armant, D Randall; Drewlo, Sascha

    2017-06-01

    Does low molecular weight heparin (LMWH) require heparin-binding epidermal growth factor (EGF)-like growth factor (HBEGF) signaling to induce extravillous trophoblast differentiation and decrease apoptosis during oxidative stress? LMWH increased HBEGF expression and secretion, and HBEGF signaling was required to stimulate trophoblast extravillous differentiation, increase invasion in vitro and reduce trophoblast apoptosis during oxidative stress. Abnormal trophoblast differentiation and survival contribute to placental insufficiency syndromes, including preeclampsia and intrauterine growth restriction. Preeclampsia often manifests as a pro-thrombotic state, with unsuccessful transformation of the spiral arteries that reduces oxygen supply and can produce placental infarction. LMWH improves placental function by increasing blood flow. Recent data suggest that the actions of LMWH transcend its anti-coagulative properties, but the molecular mechanism is unknown. There is evidence that LMWH alters the expression of human HBEGF in trophoblast cells, which regulates human trophoblast pathophysiology. HBEGF, itself, is capable of increasing trophoblast survival and invasiveness. First-trimester placental explants and the HTR-8/SVneo cell line, established using extravillous trophoblast outgrowths from first-trimester villous explants, were treated in vitro with LMWH to examine the effects on HBEGF signaling and trophoblast function under normal physiological and pathological conditions. A highly specific antagonist of HBEGF and other inhibitors of HBEGF downstream signaling were used to determine the relationship between LMWH treatment and HBEGF. Placental tissues (n = 5) were obtained with IRB approval and patient consent from first-trimester terminations. Placental explants and HTR-8/SVneo cells were cultured on plastic or Matrigel™ and treated with a therapeutic dose of LMWH (Enoxaparin; 10 IU/ml), with or without CRM197, pan Erb-B2 Receptor Tyrosine Kinase (ERBB

  11. Admissible Crosstalk Limits in a Two Colour Interferometers for Plasma Density Diagnostics. A Reduction Algorithm

    International Nuclear Information System (INIS)

    Sanchez, M.; Esteban, L.; Kornejew, P.; Hirsch, M.

    2008-01-01

    Mid Infrared (10,6 μm CO 2 laser lines) interferometers as a plasma density diagnostic must use two-colour systems with superposed interferometers beams at different wavelengths in order to cope with mechanical vibrations and drifts. They require a highly precise phase difference measurement where all sources of error must be reduced. One of these is the cross-talk between the signals which creates nonlinear spurious periodic mixing products. The reason may be either optical or electrical crosstalk both resulting in similar perturbations of the measurement. In the TJII interferometer a post-processing algorithm is used to reduce the crosstalk in the data. This post-processing procedure is not appropriate for very long pulses, as it is the case for in new tokamak (ITER) or stellarator (W7-X) projects. In both cases an on-line reduction process is required or--even better--the unwanted signal components must be reduced in the system itself CO 2 laser interferometers which as the second wavelength use the CO laser line (5,3 μm), may apply a single common detector sensitive to both wavelengths and separate the corresponding IF signals by appropriate bandpass filters. This reduces complexity of the optical arrangement and avoids a possible source of vibration induced phase noise as both signals share the same beam path. To avoid cross talk in this arrangement filtering must be appropriate. In this paper we present calculations to define the limits of crosstalk for a desired plasma density precision. A crosstalk reduction algorithm has been developed and is applied to experimental results from TJ-II pulses. Results from a single detector arrangement as under investigation for the CO 2 /CO laser interferometer developed for W7-X are presented

  12. Motion tolerant iterative reconstruction algorithm for cone-beam helical CT imaging

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Hisashi; Goto, Taiga; Hirokawa, Koichi; Miyazaki, Osamu [Hitachi Medical Corporation, Chiba-ken (Japan). CT System Div.

    2011-07-01

    We have developed a new advanced iterative reconstruction algorithm for cone-beam helical CT. The features of this algorithm are: (a) it uses separable paraboloidal surrogate (SPS) technique as a foundation for reconstruction to reduce noise and cone-beam artifact, (b) it uses a view weight in the back-projection process to reduce motion artifact. To confirm the improvement of our proposed algorithm over other existing algorithm, such as Feldkamp-Davis-Kress (FDK) or SPS algorithm, we compared the motion artifact reduction, image noise reduction (standard deviation of CT number), and cone-beam artifact reduction on simulated and clinical data set. Our results demonstrate that the proposed algorithm dramatically reduces motion artifacts compared with the SPS algorithm, and decreases image noise compared with the FDK algorithm. In addition, the proposed algorithm potentially improves time resolution of iterative reconstruction. (orig.)

  13. Effect of low molecular weight heparin in combined with Shuxuetong in preventing the post-traumatic deep venous thrombosis

    Directory of Open Access Journals (Sweden)

    Li-Mian Xu

    2016-05-01

    Full Text Available Objective: To observe the effect of low molecular weight heparin in combined with Shuxuetong in preventing the post-traumatic deep venous thrombosis (DVT. Methods: A total of 120 patients with post-traumatic DVT who were admitted in our hospital from February, 2014 to February, 2015 were included in the study and divided into the treatment group and the control group with 60 cases in each group according to different treatment protocols. The patients in the treatment group were given subcutaneous injection of low molecular weight heparin calcium and intravenous drip of Shuxuetong, while the patients in the control group were only given subcutaneous injection of low molecular weight heparin calcium. The changes of swelling degrees and coagulation indicators of the affected limb before and after treatment, and the clinical efficacy in the two groups were compared. Results: The total effective rate in the treatment group was significantly higher than that in the control group. The mean range of the perimeter 15cm above and below the bilateral knee joints after treatment in the treatment group was significantly lower than that in the control group. The shrinking rate of the mean range of the perimeter of the bilateral limbs in the treatment group was significantly higher than that in the control group. The comparison of PT, APTT, FIB, and INR before treatment between the two groups was not statistically significant. PT, APTT, and INR after treatment in the treatment group were significantly higher than those in the control group, while FIB was significantly lower than that in the control group. Conclusions: The low molecular weight heparin in combined with Shuxuetong can effectively prevent the post-traumatic DVT, with no requirement of monitoring of the bleeding tendency and safety.

  14. The heparin-binding site in tetranectin is located in the N-terminal region and binding does not involve the carbohydrate recognition domain.

    Science.gov (United States)

    Lorentsen, R H; Graversen, J H; Caterer, N R; Thogersen, H C; Etzerodt, M

    2000-04-01

    Tetranectin is a homotrimeric plasma and extracellular-matrix protein that binds plasminogen and complex sulphated polysaccharides including heparin. In terms of primary and tertiary structure, tetranectin is related to the collectin family of Ca(2+)-binding C-type lectins. Tetranectin is encoded in three exons. Exon 3 encodes the carbohydrate recognition domain, which binds to kringle 4 in plasminogen at low levels of Ca(2+). Exon 2 encodes an alpha-helix, which is necessary and sufficient to govern the trimerization of tetranectin by assembling into a triple-helical coiled-coil structural element. Here we show that the heparin-binding site in tetranectin resides not in the carbohydrate recognition domain but within the N-terminal region, comprising the 16 amino acid residues encoded by exon 1. In particular, the lysine residues in the decapeptide segment KPKKIVNAKK (tetranectin residues 6-15) are shown to be of primary importance in heparin binding.

  15. Monitoring of unfractionated heparin with rotational thrombelastometry using the prothrombinase-induced clotting time reagent (PiCT®).

    Science.gov (United States)

    Schaden, E; Jilch, S; Hacker, S; Schober, A; Kozek-Langenecker, S

    2012-12-24

    To achieve sufficient and safe anticoagulation with unfractionated heparin (UFH) a close and reliable drug monitoring is necessary. In general, the activated partial thromboplastin time (APTT) is used for this purpose. In acute phase response, however, the APTT test procedure might be unreliable e.g. with false low results in the presence of elevated factor VIII. In this so called heparin resistance, measurement of anti-Xa activity is recommended over APTT to avoid potentially harmful dose escalation. A combination of anti-Xa measurement and global hemostatic testing with ROTEM® employing the anti-Xa sensitive PiCT® reagent showed high correlation with enoxaparin levels. This test modification could also be suitable for monitoring UFH. Aim of the study was to evaluate the correlation between PiCT®-ROTEM® and levels of UFH. In this in-vitro study blood samples from healthy volunteers were spiked with UFH and subjected to different ROTEM® tests. There was a linear correlation between UFH level and clotting time (CT) in the PiCT®-ROTEM® test with an excellent correlation coefficient of 0.92. Additional endpoints showed similar results (PiCT®-ROTEM® MaxVel r = -0.85 and PiCT®-ROTEM® t_MaxVel r = 0.88). As a point-of-care applicable tool ROTEM® is immediately at hand. If further clinical studies confirm sensitivity in heparin resistance, PiCT®-ROTEM® could permit rapid UFH dose adjustments especially required in critical illness with acute phase response. Copyright © 2012 Elsevier B.V. All rights reserved.

  16. Self-Assembled Lipid Nanoparticles for Oral Delivery of Heparin-Coated Iron Oxide Nanoparticles for Theranostic Purposes.

    Science.gov (United States)

    Truzzi, Eleonora; Bongio, Chiara; Sacchetti, Francesca; Maretti, Eleonora; Montanari, Monica; Iannuccelli, Valentina; Vismara, Elena; Leo, Eliana

    2017-06-09

    Recently, solid lipid nanoparticles (SLNs) have attracted increasing attention owing to their potential as an oral delivery system, promoting intestinal absorption in the lymphatic circulation which plays a role in disseminating metastatic cancer cells and infectious agents throughout the body. SLN features can be exploited for the oral delivery of theranostics. Therefore, the aim of this work was to design and characterise self-assembled lipid nanoparticles (SALNs) to encapsulate and stabilise iron oxide nanoparticles non-covalently coated with heparin (Fe@hepa) as a model of a theranostic tool. SALNs were characterised for physico-chemical properties (particle size, surface charge, encapsulation efficiency, in vitro stability, and heparin leakage), as well as in vitro cytotoxicity by methyl thiazole tetrazolium (MTT) assay and cell internalisation in CaCo-2, a cell line model used as an indirect indication of intestinal lymphatic absorption. SALNs of about 180 nm, which are stable in suspension and have a high encapsulation efficiency (>90%) were obtained. SALNs were able to stabilise the heparin coating of Fe@hepa, which are typically unstable in physiological environments. Moreover, SALNs-Fe@hepa showed no cytotoxicity, although their ability to be internalised into CaCo-2 cells was highlighted by confocal microscopy analysis. Therefore, the results indicated that SALNs can be considered as a promising tool to orally deliver theranostic Fe@hepa into the lymphatic circulation, although further in vivo studies are needed to comprehend further potential applications.

  17. Redox and pH Responsive Poly (Amidoamine Dendrimer-Heparin Conjugates via Disulfide Linkages for Letrozole Delivery

    Directory of Open Access Journals (Sweden)

    Thanh Luan Nguyen

    2017-01-01

    Full Text Available Heparin (Hep conjugated to poly (amidoamine dendrimer G3.5 (P via redox-sensitive disulfide bond (P-SS-Hep was studied. The redox and pH dual-responsive nanocarriers were prepared by a simple method that minimized many complex steps as previous studies. The functional characterization of G3.5 coated Hep was investigated by the proton nuclear magnetic resonance spectroscopy. The size and formation were characterized by the dynamic light scattering, zeta potential, and transmission electron microscopy. P-SS-Hep was spherical in shape with average diameter about 11 nm loaded with more than 20% letrozole. This drug carrier could not only eliminate toxicity to cells and improve the drugs solubility but also increase biocompatibility of the system under reductive environment of glutathione. In particular, P-SS-Hep could enhance the effectiveness of cancer therapy after removing Hep from the surface. These results demonstrated that the P-SS-Hep conjugates could be a promising candidate as redox and pH responsive nanocarriers for cancer chemotherapy.

  18. Covalent co-immobilization of heparin/laminin complex that with different concentration ratio on titanium surface for selectively direction of platelets and vascular cells behavior

    International Nuclear Information System (INIS)

    Wang, Jian; Chen, Yuan; Liu, Tao; Wang, Xue; Liu, Yang; Wang, Yuan; Chen, Junying; Huang, Nan

    2014-01-01

    Highlights: • Extracellular matrix inspired surface modification with fibronectin, heparin and VEGF to construct a favorable microenvironment for selectively anticoagulant and promote endothelialization. • Take the advantage of specific intermolecular interaction, the bioactivity of above biomolecules was more efficiently maintained in compared with the common used covalent immobilization method. • Poly-l-lysine was used as a novel interlayer for surface amination, and in comparison, PLL coating was more feasible and the degradation product had no harm to human body. - Abstract: Surface biofunctional modification of coronary artery stent to improve the hemocompatibility and selectively accelerate endothelium regeneration but prevent restenosis have been become a new hotspot. For this, a novel method was developed in this work by co-immobilization of Ln and heparin complex on poly-L-lysine modified Ti surface. Take the advantage of the specific interaction between Ln and heparin, Ln and heparin complexes with different concentration ratios were set up for creating different exposure density of these two types of biomolecules. According to biocompatibility evaluation results, the Hep/Ln complexes modified surface displayed less platelet adhesion and activation. Especially, on L(150)H and L(200)H surface, the AT III binding quantity, APTT value and anti-coagulation property of modified surface were significantly promoted. Furthermore, the adherent density and proliferation activity of ECs and EPCs were positively correlated with Ln concentration. Notably, the proliferation of both ECs and EPCs on L(100)H, L(150)H and L(200)H surface were greatly promoted. Another hand, the proliferation activity of SMCs was significantly inhibited on Hep/Ln modified surfaces, which was considered mainly due to the inhibitory effect of heparin to SMCs. According to the existing results, this study demonstrated that in a certain range of heparin and laminin concentration ratio

  19. A single center retrospective cohort study comparing low-molecular-weight heparins to direct oral anticoagulants for the treatment of venous thromboembolism in patients with cancer - A real world experience.

    Science.gov (United States)

    Phelps, Megan K; Wiczer, Tracy E; Erdeljac, H Paige; Van Deusen, Kelsey R; Porter, Kyle; Philips, Gary; Wang, Tzu-Fei

    2018-01-01

    Introduction Low-molecular-weight heparins are the standard treatment for cancer-associated thrombosis. Recently, direct oral anticoagulants are a new option for thrombosis treatment; however, data supporting the use of direct oral anticoagulants for cancer-associated thrombosis are limited. Objectives The primary objective of this study was to determine the rate of recurrent cancer-associated thrombosis and major bleeding within 6 months of starting either low-molecular-weight heparin or direct oral anticoagulant for treatment of cancer-associated thrombosis. Secondary objectives were to determine the rates of clinically relevant-non-major bleeding and all-cause mortality. Patients/methods This is a retrospective cohort study including adults with cancer-associated thrombosis treated with low-molecular-weight heparin or direct oral anticoagulant between 2010 and 2016 at the Ohio State University. Medical records were reviewed for 6 months after initiation of anticoagulation or until the occurrence of recurrent cancer-associated thrombosis, major bleeding, cessation of anticoagulation of interest, or death, whichever occurred first. Results Four hundred and eighty patients were included (290 low-molecular-weight heparin and 190 direct oral anticoagulant). Patients treated with direct oral anticoagulant were found to carry "lower risk" features including cancer with lower VTE risk and lower rate of metastatic disease. After adjustment for baseline differences, there was no significant difference in the rate of recurrent cancer-associated thrombosis (7.2% low-molecular-weight heparin vs 6.3% direct oral anticoagulant, p = 0.71) or major bleeding (7.6% low-molecular-weight heparin vs 2.6% direct oral anticoagulant, p = 0.08). Conclusions Our study demonstrates that in a select population of cancer patients with VTE, direct oral anticoagulant use can be as effective and safe compared to the standard therapy with low-molecular-weight heparin.

  20. Reduction of artifacts caused by orthopedic hardware in the spine in spectral detector CT examinations using virtual monoenergetic image reconstructions and metal-artifact-reduction algorithms

    Energy Technology Data Exchange (ETDEWEB)

    Grosse Hokamp, Nils; Neuhaus, V.; Abdullayev, N.; Laukamp, K.; Lennartz, S.; Mpotsaris, A.; Borggrefe, J. [University Hospital Cologne, Department of Diagnostic and Interventional Radiology, Cologne (Germany)

    2018-02-15

    Aim of this study was to assess the artifact reduction in patients with orthopedic hardware in the spine as provided by (1) metal-artifact-reduction algorithms (O-MAR) and (2) virtual monoenergetic images (MonoE) as provided by spectral detector CT (SDCT) compared to conventional iterative reconstruction (CI). In all, 28 consecutive patients with orthopedic hardware in the spine who underwent SDCT-examinations were included. CI, O-MAR and MonoE (40-200 keV) images were reconstructed. Attenuation (HU) and noise (SD) were measured in order to calculate signal-to-noise ratio (SNR) of paravertebral muscle and spinal canal. Subjective image quality was assessed by two radiologists in terms of image quality and extent of artifact reduction. O-MAR and high-keV MonoE showed significant decrease of hypodense artifacts in terms of higher attenuation as compared to CI (CI vs O-MAR, 200 keV MonoE: -396.5HU vs. -115.2HU, -48.1HU; both p ≤ 0.001). Further, artifacts as depicted by noise were reduced in O-MAR and high-keV MonoE as compared to CI in (1) paravertebral muscle and (2) spinal canal - CI vs. O-MAR/200 keV: (1) 34.7 ± 19.0 HU vs. 26.4 ± 14.4 HU, p ≤ 0.05/27.4 ± 16.1, n.s.; (2) 103.4 ± 61.3 HU vs. 72.6 ± 62.6 HU/60.9 ± 40.1 HU, both p ≤ 0.001. Subjectively both O-MAR and high-keV images yielded an artifact reduction in up to 24/28 patients. Both, O-MAR and high-keV MonoE reconstructions as provided by SDCT lead to objective and subjective artifact reduction, thus the combination of O-MAR and MonoE seems promising for further reduction. (orig.)

  1. Mr 25,000 heparin-binding protein from guinea pig brain is a high molecular weight form of basic fibroblast growth factor.

    OpenAIRE

    Moscatelli, D; Joseph-Silverstein, J; Manejias, R; Rifkin, D B

    1987-01-01

    A Mr 25,000 form of basic fibroblast growth factor (bFGF) has been isolated from guinea pig brain along with the typical Mr 18,000 form. Both forms were purified to homogeneity by a combination of heparin-affinity chromatography and ion-exchange chromatography on an FPLC Mono S column. The Mr 25,000 form, like the Mr 18,000 form, was not eluted from the heparin-affinity column with 0.95 M NaCl, but was eluted with 2 M NaCl. The Mr 25,000 guinea pig protein stimulated plasminogen activator pro...

  2. In vitro induction of protein complexes between bevacizumab, VEGF-A¹⁶⁵ and heparin: explanation for deposits observed on endothelial veins in monkey eyes.

    Science.gov (United States)

    Julien, Sylvie; Biesemeier, Antje; Schraermeyer, Ulrich

    2013-04-01

    By investigating the effects of intravitreal bevacizumab on retinal vessels of monkeys, we found that bevacizumab accumulated locally at high concentration within individual blood vessels. It formed electron-dense fibrous deposits between endothelial cells and erythrocytes or granulocytes inducing retinal vein thrombosis. To better characterise the observed deposits, we investigated in vitro whether these deposits result from a complex between bevacizumab, vascular endothelial growth factor (VEGF)-A(165) and heparin. Cynomolgus monkeys were intravitreally injected with 1.25 mg bevacizumab. The eyes were enucleated between 1 and 14 days after injection and investigated by electron microscopy and immunohistochemistry. Human umbilical vein endothelial cells (HUVEC) were incubated with bevacizumab, VEGF-A(165) and heparin at different concentrations. Treatments with ranibizumab served as control. Bevacizumab and ranibizumab were detected immunohistochemically using Cy-3 or immunogold labelled antibodies. Treated animals showed bevacizumab locally at high concentration within retinal blood vessels. Electron-dense deposits inside retinal vessels and between erythrocytes were detected in three out of four treated monkeys. In vitro, many globular aggregates heavily stained with anti-human IgG were only observed with equimolar amounts (240 nM) of bevacizumab and VEGF-A(165) and 0.2 U/ml heparin and not after ranibizumab treatment. The immunogold labelling specifically localised ultrastructurally the complexes formed between bevacizumab, VEGF-A(165) and heparin at the surfaces of HUVEC cells. Heparin promotes bevacizumab immune complex deposition on to endothelial cells. Our in vitro results could explain the presence of deposits observed on endothelial veins in monkey eyes intravitreally injected with bevacizumab.

  3. Heparin-immobilized hydroxyapatite nanoparticles as a lactoferrin delivery system for improving osteogenic differentiation of adipose-derived stem cells

    International Nuclear Information System (INIS)

    Kim, Sung Eun; Yun, Young-Pil; Kim, Hak-Jun; Lee, Deok-Won; Shim, Kyu-Sik; Jeon, Daniel I; Rhee, Jin-Kyu; Park, Kyeongsoon

    2016-01-01

    The aim of this study is to fabricate lactoferrin (LF)-carrying hydroxyapatite nanoparticles (HAp NPs) to enhance osteogenic differentiation of rabbit adipose-derived stem cells (rADSCs). HAp NPs were modified with heparin-dopamine (Hep-DOPA) (Hep-HAp) and further immobilized with LF (LF/Hep-HAp). Heparin immobilization on HAp NPs prevented aggregation of HAp NPs in aqueous solution and prolonged the release of LF from LF/Hep-HAp NPs. In vitro studies of rADSCs have demonstrated that LF-Hep/HAp NPs significantly increase alkaline phosphatase (ALP) activity, calcium deposition, and both mRNA expression of osteocalcin (OCN) and osteopontin (OPN) in comparison with HAp and Hep-HAp NPs. These results suggest that LF/Hep-HAp NPs can effectively induce osteogenic differentiation of rADSCs. (paper)

  4. Assessing image quality and dose reduction of a new x-ray computed tomography iterative reconstruction algorithm using model observers

    International Nuclear Information System (INIS)

    Tseng, Hsin-Wu; Kupinski, Matthew A.; Fan, Jiahua; Sainath, Paavana; Hsieh, Jiang

    2014-01-01

    Purpose: A number of different techniques have been developed to reduce radiation dose in x-ray computed tomography (CT) imaging. In this paper, the authors will compare task-based measures of image quality of CT images reconstructed by two algorithms: conventional filtered back projection (FBP), and a new iterative reconstruction algorithm (IR). Methods: To assess image quality, the authors used the performance of a channelized Hotelling observer acting on reconstructed image slices. The selected channels are dense difference Gaussian channels (DDOG).A body phantom and a head phantom were imaged 50 times at different dose levels to obtain the data needed to assess image quality. The phantoms consisted of uniform backgrounds with low contrast signals embedded at various locations. The tasks the observer model performed included (1) detection of a signal of known location and shape, and (2) detection and localization of a signal of known shape. The employed DDOG channels are based on the response of the human visual system. Performance was assessed using the areas under ROC curves and areas under localization ROC curves. Results: For signal known exactly (SKE) and location unknown/signal shape known tasks with circular signals of different sizes and contrasts, the authors’ task-based measures showed that a FBP equivalent image quality can be achieved at lower dose levels using the IR algorithm. For the SKE case, the range of dose reduction is 50%–67% (head phantom) and 68%–82% (body phantom). For the study of location unknown/signal shape known, the dose reduction range can be reached at 67%–75% for head phantom and 67%–77% for body phantom case. These results suggest that the IR images at lower dose settings can reach the same image quality when compared to full dose conventional FBP images. Conclusions: The work presented provides an objective way to quantitatively assess the image quality of a newly introduced CT IR algorithm. The performance of the

  5. The impact of preparation parameters on typical attributes of chitosan-heparin nanohydrogels: particle size, loading efficiency, and drug release.

    Science.gov (United States)

    Shahbazi, Mohammad-Ali; Hamidi, Mehrdad

    2013-11-01

    Today, developing an optimized nanoparticle (NP) preparation procedure is of paramount importance in all nanoparticulate drug delivery researches, leading to expanding more operative and clinically validated nanomedicines. In this study, a one-at-a-time experimental approach was used for evaluating the effect of various preparation factors on size, loading, and drug release of hydrogel NPs prepared with ionotropic gelation between heparin and chitosan. The size, loading efficiency (LE) and drug release profile of the NPs were evaluated when the chitosan molecular weight, chitosan concentration, heparin addition time to chitosan solution, heparin concentration, pH value of chitosan solution, temperature, and mixing rate were changed separately while other factors were in optimum condition. The results displayed that size and LE are highly influenced by chitosan concentration, getting an optimum of 63 ± 0.57 and 75.19 ± 2.65, respectively, when chitosan concentration was 0.75 mg/ml. Besides, heparin addition time of 3 min leaded to 74.1 ± 0.79 % LE with no sensible effect on size and release profile. In addition, pH 5.5 showed a minimum size of 63 ± 1.87, maximum LE of 73.81 ± 3.13 and the slowest drug release with 63.71 ± 3.84 % during one week. Although LE was not affected by temperature, size and release reduced to 63 ± 0 and 74.21 ± 1.99% when temperature increased from 25°C to 55°C. Also, continuous increase of mixer rate from 500 to 3500 rpm resulted in constant enhancement of LE from 58.3 ± 3.6 to 74.4 ± 2.59 as well as remarkable decrease in size from 148 ± 4.88 to 63 ± 2.64.

  6. Effect of alteplase thrombolysis sequenced by low molecular heparin calcium antithrombosis on the neurological function and serum cytokines in patients with cerebral infarction

    Directory of Open Access Journals (Sweden)

    Yi-Ping Dan

    2017-04-01

    Full Text Available Objective: To study the effect of alteplase thrombolysis sequenced by low molecular heparin calcium antithrombosis on the neurological function and serum cytokines in patients with cerebral infarction. Methods: Patients with acute cerebral infarction who received alteplase thrombolysis in Zigong Fourth People's Hospital between June 2014 and October 2016 were retrospectively analyzed and divided into the intervention group who received low molecular heparin calcium treatment and the control group who did not receive low molecular heparin calcium treatment. The serum was collected before and after treatment to determine the contents of platelet activation factors, nerve injury molecules, soluble apoptotic molecules and growth factors. Results: Serum CD62p, CD63, PAF, GMP-140, NSE, S100B, GFAP, sFas, sFasL, sTRAIL, IGF-1, VEGF, BDNF and bFGF levels of both groups of patients after treatment were lower than those before treatment, serum CD62p, CD63, PAF, GMP-140, NSE, S100B, GFAP, sFas, sFasL and sTRAIL levels of intervention group after treatment were lower than those of control group while IGF-1, VEGF, BDNF and bFGF levels were higher than those of control group. Conclusion: Alteplase thrombolysis sequenced by low molecular heparin calcium antithrombosis for acute cerebral infarction can inhibit platelet activation and cell apoptosis, alleviate nerve injury and improve neurotrophy status.

  7. Impact of INR monitoring, reversal agent use, heparin bridging, and anticoagulant interruption on rebleeding and thromboembolism in acute gastrointestinal bleeding.

    Directory of Open Access Journals (Sweden)

    Naoyoshi Nagata

    Full Text Available Anticoagulant management of acute gastrointestinal bleeding (GIB during the pre-endoscopic period has not been fully addressed in American, European, or Asian guidelines. This study sought to evaluate the risks of rebleeding and thromboembolism in anticoagulated patients with acute GIB.Baseline, endoscopy, and outcome data were reviewed for 314 patients with acute GIB: 157 anticoagulant users and 157 age-, sex-, and important risk-matched non-users. Data were also compared between direct oral anticoagulants (DOACs and warfarin users.Between anticoagulant users and non-users, of whom 70% underwent early endoscopy, no endoscopy-related adverse events or significant differences were found in the rate of endoscopic therapy need, transfusion need, rebleeding, or thromboembolism. Rebleeding was associated with shock, comorbidities, low platelet count and albumin level, and low-dose aspirin use but not HAS-BLED score, any endoscopic results, heparin bridge, or international normalized ratio (INR ≥ 2.5. Risks for thromboembolism were INR ≥ 2.5, difference in onset and pre-endoscopic INR, reversal agent use, and anticoagulant interruption but not CHA2DS2-VASc score, any endoscopic results, or heparin bridge. In patients without reversal agent use, heparin bridge, or anticoagulant interruption, there was only one rebleeding event and no thromboembolic events. Warfarin users had a significantly higher transfusion need than DOACs users.Endoscopy appears to be safe for anticoagulant users with acute GIB compared with non-users. Patient background factors were associated with rebleeding, whereas anticoagulant management factors (e.g. INR correction, reversal agent use, and drug interruption were associated with thromboembolism. Early intervention without reversal agent use, heparin bridge, or anticoagulant interruption may be warranted for acute GIB.

  8. Degranulating mast cells in fibrotic regions of human tumors and evidence that mast cell heparin interferes with the growth of tumor cells through a mechanism involving fibroblasts

    International Nuclear Information System (INIS)

    Samoszuk, Michael; Kanakubo, Emi; Chan, John K

    2005-01-01

    The purpose of this study was to test the hypothesis that mast cells that are present in fibrotic regions of cancer can suppress the growth of tumor cells through an indirect mechanism involving peri-tumoral fibroblasts. We first immunostained a wide variety of human cancers for the presence of degranulated mast cells. In a subsequent series of controlled in vitro experiments, we then co-cultured UACC-812 human breast cancer cells with normal fibroblasts in the presence or absence of different combinations and doses of mast cell tryptase, mast cell heparin, a lysate of the human mast cell line HMC-1, and fibroblast growth factor-7 (FGF-7), a powerful, heparin-binding growth factor for breast epithelial cells. Degranulating mast cells were localized predominantly in the fibrous tissue of every case of breast cancer, head and neck cancer, lung cancer, ovarian cancer, non-Hodgkin's lymphoma, and Hodgkin's disease that we examined. Mast cell tryptase and HMC-1 lysate had no significant effect on the clonogenic growth of cancer cells co-cultured with fibroblasts. By contrast, mast cell heparin at multiple doses significantly reduced the size and number of colonies of tumor cells co-cultured with fibroblasts, especially in the presence of FGF-7. Neither heparin nor FGF-7, individually or in combination, produced any significant effect on the clonogenic growth of breast cancer cells cultured without fibroblasts. Degranulating mast cells are restricted to peri-tumoral fibrous tissue, and mast cell heparin is a powerful inhibitor of clonogenic growth of tumor cells co-cultured with fibroblasts. These results may help to explain the well-known ability of heparin to inhibit the growth of primary and metastatic tumors

  9. Degranulating mast cells in fibrotic regions of human tumors and evidence that mast cell heparin interferes with the growth of tumor cells through a mechanism involving fibroblasts

    Directory of Open Access Journals (Sweden)

    Kanakubo Emi

    2005-09-01

    Full Text Available Abstract Background The purpose of this study was to test the hypothesis that mast cells that are present in fibrotic regions of cancer can suppress the growth of tumor cells through an indirect mechanism involving peri-tumoral fibroblasts. Methods We first immunostained a wide variety of human cancers for the presence of degranulated mast cells. In a subsequent series of controlled in vitro experiments, we then co-cultured UACC-812 human breast cancer cells with normal fibroblasts in the presence or absence of different combinations and doses of mast cell tryptase, mast cell heparin, a lysate of the human mast cell line HMC-1, and fibroblast growth factor-7 (FGF-7, a powerful, heparin-binding growth factor for breast epithelial cells. Results Degranulating mast cells were localized predominantly in the fibrous tissue of every case of breast cancer, head and neck cancer, lung cancer, ovarian cancer, non-Hodgkin's lymphoma, and Hodgkin's disease that we examined. Mast cell tryptase and HMC-1 lysate had no significant effect on the clonogenic growth of cancer cells co-cultured with fibroblasts. By contrast, mast cell heparin at multiple doses significantly reduced the size and number of colonies of tumor cells co-cultured with fibroblasts, especially in the presence of FGF-7. Neither heparin nor FGF-7, individually or in combination, produced any significant effect on the clonogenic growth of breast cancer cells cultured without fibroblasts. Conclusion Degranulating mast cells are restricted to peri-tumoral fibrous tissue, and mast cell heparin is a powerful inhibitor of clonogenic growth of tumor cells co-cultured with fibroblasts. These results may help to explain the well-known ability of heparin to inhibit the growth of primary and metastatic tumors.

  10. New Search Space Reduction Algorithm for Vertical Reference Trajectory Optimization

    Directory of Open Access Journals (Sweden)

    Alejandro MURRIETA-MENDOZA

    2016-06-01

    Full Text Available Burning the fuel required to sustain a given flight releases pollution such as carbon dioxide and nitrogen oxides, and the amount of fuel consumed is also a significant expense for airlines. It is desirable to reduce fuel consumption to reduce both pollution and flight costs. To increase fuel savings in a given flight, one option is to compute the most economical vertical reference trajectory (or flight plan. A deterministic algorithm was developed using a numerical aircraft performance model to determine the most economical vertical flight profile considering take-off weight, flight distance, step climb and weather conditions. This algorithm is based on linear interpolations of the performance model using the Lagrange interpolation method. The algorithm downloads the latest available forecast from Environment Canada according to the departure date and flight coordinates, and calculates the optimal trajectory taking into account the effects of wind and temperature. Techniques to avoid unnecessary calculations are implemented to reduce the computation time. The costs of the reference trajectories proposed by the algorithm are compared with the costs of the reference trajectories proposed by a commercial flight management system using the fuel consumption estimated by the FlightSim® simulator made by Presagis®.

  11. A Dynamic Enhancement With Background Reduction Algorithm: Overview and Application to Satellite-Based Dust Storm Detection

    Science.gov (United States)

    Miller, Steven D.; Bankert, Richard L.; Solbrig, Jeremy E.; Forsythe, John M.; Noh, Yoo-Jeong; Grasso, Lewis D.

    2017-12-01

    This paper describes a Dynamic Enhancement Background Reduction Algorithm (DEBRA) applicable to multispectral satellite imaging radiometers. DEBRA uses ancillary information about the clear-sky background to reduce false detections of atmospheric parameters in complex scenes. Applied here to the detection of lofted dust, DEBRA enlists a surface emissivity database coupled with a climatological database of surface temperature to approximate the clear-sky equivalent signal for selected infrared-based multispectral dust detection tests. This background allows for suppression of false alarms caused by land surface features while retaining some ability to detect dust above those problematic surfaces. The algorithm is applicable to both day and nighttime observations and enables weighted combinations of dust detection tests. The results are provided quantitatively, as a detection confidence factor [0, 1], but are also readily visualized as enhanced imagery. Utilizing the DEBRA confidence factor as a scaling factor in false color red/green/blue imagery enables depiction of the targeted parameter in the context of the local meteorology and topography. In this way, the method holds utility to both automated clients and human analysts alike. Examples of DEBRA performance from notable dust storms and comparisons against other detection methods and independent observations are presented.

  12. M4GB : Efficient Groebner Basis algorithm

    NARCIS (Netherlands)

    R.H. Makarim (Rusydi); M.M.J. Stevens (Marc)

    2017-01-01

    textabstractWe introduce a new efficient algorithm for computing Groebner-bases named M4GB. Like Faugere's algorithm F4 it is an extension of Buchberger's algorithm that describes: how to store already computed (tail-)reduced multiples of basis polynomials to prevent redundant work in the reduction

  13. Bilateral rectal sheath hematomas after low-molecular weight heparin treatment in uremia.

    Science.gov (United States)

    Xu, Lu; Liu, Lei; Li, Xinjian

    2017-11-01

    Rectus sheath hematomas (RSHs) are uncommon. They are usually unilateral and rarely bilateral. In this paper, we report the first case of spontaneous bilateral RSHs in a uremic patient after the administration of the first dose of low-molecular weight heparin during hemodialysis. The most interesting aspect of this case is that the main symptom of RSH in our patient was urinary bladder irritation. We highlight the importance of the prompt diagnosis and management of this medical emergency.

  14. Successful Deep Inferior Epigastric Perforator Flap Harvest despite Preoperative Therapeutic Subcutaneous Heparin Administration into the Abdominal Pannus.

    Science.gov (United States)

    Duncumb, Joseph W; Miyagi, Kana; Forouhi, Parto; Malata, Charles M

    2016-01-01

    Abdominal free flaps for microsurgical breast reconstruction are most commonly harvested based on the deep inferior epigastric vessels that supply skin and fat via perforators through the rectus muscle and sheath. Intact perforator anatomy and connections are vital for subsequent optimal flap perfusion and avoidance of necrosis, be it partial or total. The intraflap vessels are delicate and easily damaged and it is generally advised that patients should avoid heparin injection into the abdominal pannus preoperatively as this may compromise the vascular perforators through direct needle laceration, pressure from bruising, haematoma formation, or perforator thrombosis secondary to external compression. We report three cases of successful deep inferior epigastric perforator (DIEP) flap harvest despite patients injecting therapeutic doses of low molecular weight heparin into their abdomens for thrombosed central venous lines (portacaths™) used for administering primary chemotherapy in breast cancer.

  15. Successful Deep Inferior Epigastric Perforator Flap Harvest despite Preoperative Therapeutic Subcutaneous Heparin Administration into the Abdominal Pannus

    Directory of Open Access Journals (Sweden)

    Joseph W. Duncumb

    2016-01-01

    Full Text Available Abdominal free flaps for microsurgical breast reconstruction are most commonly harvested based on the deep inferior epigastric vessels that supply skin and fat via perforators through the rectus muscle and sheath. Intact perforator anatomy and connections are vital for subsequent optimal flap perfusion and avoidance of necrosis, be it partial or total. The intraflap vessels are delicate and easily damaged and it is generally advised that patients should avoid heparin injection into the abdominal pannus preoperatively as this may compromise the vascular perforators through direct needle laceration, pressure from bruising, haematoma formation, or perforator thrombosis secondary to external compression. We report three cases of successful deep inferior epigastric perforator (DIEP flap harvest despite patients injecting therapeutic doses of low molecular weight heparin into their abdomens for thrombosed central venous lines (portacaths™ used for administering primary chemotherapy in breast cancer.

  16. The Orthogonally Partitioned EM Algorithm: Extending the EM Algorithm for Algorithmic Stability and Bias Correction Due to Imperfect Data.

    Science.gov (United States)

    Regier, Michael D; Moodie, Erica E M

    2016-05-01

    We propose an extension of the EM algorithm that exploits the common assumption of unique parameterization, corrects for biases due to missing data and measurement error, converges for the specified model when standard implementation of the EM algorithm has a low probability of convergence, and reduces a potentially complex algorithm into a sequence of smaller, simpler, self-contained EM algorithms. We use the theory surrounding the EM algorithm to derive the theoretical results of our proposal, showing that an optimal solution over the parameter space is obtained. A simulation study is used to explore the finite sample properties of the proposed extension when there is missing data and measurement error. We observe that partitioning the EM algorithm into simpler steps may provide better bias reduction in the estimation of model parameters. The ability to breakdown a complicated problem in to a series of simpler, more accessible problems will permit a broader implementation of the EM algorithm, permit the use of software packages that now implement and/or automate the EM algorithm, and make the EM algorithm more accessible to a wider and more general audience.

  17. The dangerous gamble of heparinization within two weeks of nonoperative traumatic acute subdural hematoma in patients with increased stroke risk: a case series.

    Science.gov (United States)

    McClelland, S; Mackey, S J; Kim, S S

    2014-01-01

    In traumatic acute subdural hematoma (aSDH) management, systemic anticoagulation is contraindicated, particularly during the first 2 weeks. We present two cases of patients with nonoperative aSDH whose stroke risk led to heparinization within 2 weeks of the initial hemorrhage and examine their outcomes to illustrate the risks and benefits associated with systemic anticoagulation. Two elderly males, on warfarin at baseline who developed traumatic nonoperative aSDH were heparinized within 2 weeks of aSDH onset. One patient showed a decreased SDH volume on Day 19. The second patient developed sudden onset headache with fixed/dilated pupils on Day 5. In this patient, a CT scan of the brain revealed marked enlargement of the aSDH from 0.9 to 2.4 cm with midline shift of 1.5 cm, and uncal herniation that was incompatible with life. Heparinization within two weeks of aSDH may cause SDH enlargement resulting in rapidly fatal neurologic deterioration. Further study is needed to more definitively address this issue.

  18. Endothelial glycocalyx degradation induces endogenous heparinization in patients with severe injury and early traumatic coagulopathy

    DEFF Research Database (Denmark)

    Ostrowski, Sisse R; Johansson, Pär I

    2012-01-01

    There is emerging evidence that early trauma-induced coagulopathy (TIC) is mechanistically linked to disruption of the vascular endothelium and its glycocalyx, assessed by thrombomodulin and syndecan 1, respectively. This study evaluated if degradation of the endothelial glycocalyx and ensuing...... release of its heparin-like substances induce autoheparinization and thereby contributes to TIC....

  19. LOW-MOLECULAR-WEIGHT HEPARIN TREATMENT FAILURE IN PREVENTION OF PROSTHETIC MITRAL VALVE THROMBOSIS

    OpenAIRE

    David Šuran; Vojko Kanič; Tatjana Golob Gulič; Husam Franjo Naji; Robert Lipovec

    2009-01-01

    Background Prosthetic heart valve thrombosis (PHVT) represents a dangerous postoperative complication following prosthetic heart valve replacement. Incidence varies according to different data from 0.5–4 % per year following mitral or aortic valve replacement in spite of adequate oral anticoagulation with coumarins. Case report We are presenting a case of prosthetic mitral valve thrombosis as a result of 6-month lowmolecular-weight heparin (LMWH) (nadroparine) treatment failure. Our pat...

  20. [Effect of early intervention with heparin on function of coagulopathy, liver and kidney in rats with exertional heatstroke under the ambient air of high temperature and low humidity].

    Science.gov (United States)

    Yu, Yang; Wei, Yuying; Zhang, Xiangrong; Li, Xinyu

    2018-03-01

    To explore the effects of early intervention with heparin on function of coagulopathy, liver and kidney as well as the prognosis in rats with exertional heatstroke (EHS) under the ambient air of high temperature and low humidity. 108 healthy SPF male Sprague-Dawley (SD) rats were randomly divided into normal temperature control group, EHS + normal saline (NS) group and EHS + heparin group. Of which 54 rats were collected for survival analysis (18 rats in each group), the weight change and 8-hour survival rate were observed, and Kaplan-Meier survival curves were drawn. Other 54 rats were collected for intervention experiment, the rats in each group were subdivided into 0, 1, 2 hours subgroups according to the time points of intervention with heparin after model reproduction, with 6 rats in each subgroup. The rats were placed in an artificial experiment cabin with northwest special environment, and the temperature and the relative humidity were (25.0±1.0) centigrade and (35±5)%, respectively, in normal temperature control group, and the rats were not treated in the cabin. The rats in EHS + NS group and EHS + heparin group kept running in the cabin which temperature and relative humidity were set at (43.0±0.5) centigrade and (35±5)% until the anus temperature of rats reached 43.0 centigrade, and then the rats were placed in room temperature. The rats were injected with 1 mL/kg NS or 250 U/kg heparin sodium injection through their caudal veins at 0, 1, and 2 hours, respectively, and then the blood was collected after 1.5 hours to determine the biochemical parameters including coagulation, liver and kidney as well as platelet count (PLT). (1) The weight loss of EHS + NS group and EHS + heparin group was more significant than that of normal temperature control group (g: 8.28±1.41, 8.39±1.38 vs. 2.06±1.06, both P < 0.05), but there was no significant difference between EHS + NS group and EHS + heparin group. (2) As the time went on after modeling, serum creatinine

  1. PROPOSAL OF ALGORITHM FOR ROUTE OPTIMIZATION

    OpenAIRE

    Robert Ramon de Carvalho Sousa; Abimael de Jesus Barros Costa; Eliezé Bulhões de Carvalho; Adriano de Carvalho Paranaíba; Daylyne Maerla Gomes Lima Sandoval

    2016-01-01

    This article uses “Six Sigma” methodology for the elaboration of an algorithm for routing problems which is able to obtain more efficient results than those from Clarke and Wright´s (CW) algorithm (1964) in situations of random increase of product delivery demands, facing the incapability of service level increase . In some situations, the algorithm proposed obtained more efficient results than the CW algorithm. The key factor was a reduction in the number of mistakes (on...

  2. Multichannel transfer function with dimensionality reduction

    KAUST Repository

    Kim, Han Suk

    2010-01-17

    The design of transfer functions for volume rendering is a difficult task. This is particularly true for multi-channel data sets, where multiple data values exist for each voxel. In this paper, we propose a new method for transfer function design. Our new method provides a framework to combine multiple approaches and pushes the boundary of gradient-based transfer functions to multiple channels, while still keeping the dimensionality of transfer functions to a manageable level, i.e., a maximum of three dimensions, which can be displayed visually in a straightforward way. Our approach utilizes channel intensity, gradient, curvature and texture properties of each voxel. The high-dimensional data of the domain is reduced by applying recently developed nonlinear dimensionality reduction algorithms. In this paper, we used Isomap as well as a traditional algorithm, Principle Component Analysis (PCA). Our results show that these dimensionality reduction algorithms significantly improve the transfer function design process without compromising visualization accuracy. In this publication we report on the impact of the dimensionality reduction algorithms on transfer function design for confocal microscopy data.

  3. Waste reduction algorithm used as the case study of simulated bitumen production process

    Directory of Open Access Journals (Sweden)

    Savić Marina A.

    2011-01-01

    Full Text Available Waste reduction algorithm - WAR is a tool helping process engineers for environmental impact assessment. WAR algorithm is a methodology for determining the potential environmental impact (PEI of a chemical process. In particular, the bitumen production process was analyzed following three stages: a atmospheric distillation unit, b vacuum distillation unit, and c bitumen production unit. Study was developed for the middle sized oil refinery with capacity of 5000000 tones of crude oil per year. Results highlight the most vulnerable aspects of the environmental pollution that arise during the manufacturing process of bitumen. The overall rates of PEI leaving the system (PEI/h - Iout PEI/h are: a 2.14105, b 7.17104 and c 2.36103, respectively. The overall rates of PEI generated within the system - Igen PEI/h are: a 7.75104, b -4.31104 and c -4.32102, respectively. Atmospheric distillation unit have the highest overall rate of PEI while the bitumen production unit have the lowest overall rate of PEI. Comparison of Iout PEI/h and Igen PEI/h values for the atmospheric distillation unit, shows that the overall rate of PEI generated in the system is 36.21% of the overall rate of PEI leaving the system. In the cases of vacuum distillation and bitumen production units, the overall rate of PEI generated in system have negative values, i.e. the overall rate of PEI leaving the system is reduced at 60.11% (in the vacuum distillation unit and at 18.30% (in the bitumen production unit. Analysis of the obtained results for the overall rate of PEI, expressed by weight of the product, confirms conclusions.

  4. N-terminal and C-terminal heparin-binding domain polypeptides derived from fibronectin reduce adhesion and invasion of liver cancer cells

    International Nuclear Information System (INIS)

    Tang, Nan-Hong; Chen, Yan-Lin; Wang, Xiao-Qian; Li, Xiu-Jin; Wu, Yong; Zou, Qi-Lian; Chen, Yuan-Zhong

    2010-01-01

    Fibronectin (FN) is known to be a large multifunction glycoprotein with binding sites for many substances, including N-terminal and C-terminal heparin-binding domains. We investigated the effects of highly purified rhFNHN29 and rhFNHC36 polypeptides originally cloned from the two heparin-binding domains on the adhesion and invasion of highly metastatic human hepatocellular carcinoma cells (MHCC97H) and analyzed the underlying mechanism involved. The MHCC97H cells that adhered to FN in the presence of various concentrations of rhFNHN29 and rhFNHC36 polypeptides were stained with crystal violet and measured, and the effects of rhFNHN29 and rhFNHC36 on the invasion of the MHCC97H cells were then detected using the Matrigel invasion assay as well as a lung-metastasis mouse model. The expression level of integrins and focal adhesion kinase (FAK) phosphotyrosyl protein was examined by Western blot, and the activity of matrix metalloproteinases (MMPs) and activator protein 1 (AP-1) was analyzed by gelatin zymography and the electrophoretic mobility band-shift assay (EMSA), respectively. Both of the polypeptides rhFNHN29 and rhFNHC36 inhibited adhesion and invasion of MHCC97H cells; however, rhFNHC36 exhibited inhibition at a lower dose than rhFNHN29. These inhibitory effects were mediated by integrin αvβ3 and reversed by a protein tyrosine phosphatase inhibitor. Polypeptides rhFNHN29 and rhFNHC36 abrogated the tyrosine phosphorylation of focal adhesion kinase (p-FAK) and activation of activator protein 1 (AP-1), resulting in the decrease of integrin αv, β3 and β1 expression as well as the reduction of MMP-9 activity. Polypeptides rhFNHN29 and rhFNHC36 could potentially be applicable to human liver cancer as anti-adhesive and anti-invasive agents

  5. Isolation of RNA for dot hybridization by heparin-DNase I treatment of whole cell lysate.

    Science.gov (United States)

    Krawczyk, Z; Wu, C

    1987-08-15

    We have developed a new procedure for the rapid preparation of undegraded total RNA from cultured cells for specific quantitation by dot blotting analysis. Pelleted cells are resuspended in hypotonic solution containing a ribonuclease inhibitor and heparin and disrupted by freeze-thaw. Heparin is employed as an agent for nuclear lysis, dissociation of chromosomal protein, and release of mRNA from rough endoplasmic reticulum. We eliminate chromosomal DNA by digestion with DNase I and denature the RNA in the lysate with formaldehyde. After centrifugation to remove debris, the supernatant is used directly for dot blotting. All manipulations are performed in the same microfuge tube and recovery of RNA is quantitative. The procedure is especially useful for processing large numbers of samples. We illustrate its versatility by analysis of specific RNAs in Drosophila, rat, and human cell lines. In reconstruction experiments, less than 80 molecules per cell of a small RNA (beta-globin) can be detected under highly stringent hybridization conditions, using only moderately labeled double-stranded plasmid DNA probes and short film exposures.

  6. Octasaccharide is the minimal length unit required for efficient binding of cyclophilin B to heparin and cell surface heparan sulphate.

    Science.gov (United States)

    Vanpouille, Christophe; Denys, Agnès; Carpentier, Mathieu; Pakula, Rachel; Mazurier, Joël; Allain, Fabrice

    2004-09-01

    Cyclophilin B (CyPB) is a heparin-binding protein first identified as a receptor for cyclosporin A. In previous studies, we reported that CyPB triggers chemotaxis and integrin-mediated adhesion of T-lymphocytes by way of interaction with two types of binding sites. The first site corresponds to a signalling receptor; the second site has been identified as heparan sulphate (HS) and appears crucial to induce cell adhesion. Characterization of the HS-binding unit is critical to understand the requirement of HS in pro-adhesive activity of CyPB. By using a strategy based on gel mobility shift assays with fluorophore-labelled oligosaccharides, we demonstrated that the minimal heparin unit required for efficient binding of CyPB is an octasaccharide. The mutants CyPB(KKK-) [where KKK- refers to the substitutions K3A(Lys3-->Ala)/K4A/K5A] and CyPB(DeltaYFD) (where Tyr14-Phe-Asp16 has been deleted) failed to interact with octasaccharides, confirming that the Y14FD16 and K3KK5 clusters are required for CyPB binding. Molecular modelling revealed that both clusters are spatially arranged so that they may act synergistically to form a binding site for the octasaccharide. We then demonstrated that heparin-derived octasaccharides and higher degree of polymerization oligosaccharides inhibited the interaction between CyPB and fluorophore-labelled HS chains purified from T-lymphocytes, and strongly reduced the HS-dependent pro-adhesive activity of CyPB. However, oligosaccharides or heparin were unable to restore adhesion of heparinase-treated T-lymphocytes, indicating that HS has to be present on the cell membrane to support the pro-adhesive activity of CyPB. Altogether, these results demonstrate that the octasaccharide is likely to be the minimal length unit required for efficient binding of CyPB to cell surface HS and consequent HS-dependent cell responses.

  7. SU-F-J-175: Evaluation of Metal Artifact Reduction Algorithms in Computed Tomography and Their Application to Radiation Therapy Treatment Planning

    International Nuclear Information System (INIS)

    Norris, H; Rangaraj, D; Kim, S

    2016-01-01

    Purpose: High-Z (metal) implants in CT scans cause significant streak-like artifacts in the reconstructed dataset. This results in both inaccurate CT Hounsfield units for the tissue as well as obscuration of the target and organs at risk (OARs) for radiation therapy planning. Herein we analyze two metal artifact reduction algorithms: GE’s Smart MAR and a Metal Deletion Technique (MDT) for geometric and Hounsfield Unit (HU) accuracy. Methods: A CT-to-electron density phantom, with multiple inserts of various densities and a custom Cerrobend insert (Zeff=76.8), is utilized in this continuing study. The phantom is scanned without metal (baseline) and again with the metal insert. Using one set of projection data, reconstructed CT volumes are created with filtered-back-projection (FBP) and the MAR and the MDT algorithms. Regions-of-Interest (ROIs) are evaluated for each insert for HU accuracy; the metal insert’s Full-Width-Half-Maximum (FWHM) is used to evaluate the geometric accuracy. Streak severity is quantified with an HU error metric over the phantom volume. Results: The original FBP reconstruction has a Root-Mean-Square-Error (RMSE) of 57.55 HU (STD=29.19, range=−145.8 to +79.2) compared to baseline. The MAR reconstruction has a RMSE of 20.98 HU (STD=13.92, range=−18.3 to +61.7). The MDT reconstruction has a RMSE of 10.05 HU (STD=10.5, range=−14.8 to +18.6). FWHM for baseline=162.05; FBP=161.84 (−0.13%); MAR=162.36 (+0.19%); MDT=162.99 (+0.58%). Streak severity metric for FBP=19.73 (22.659% bad pixels); MAR=8.743 (9.538% bad); MDT=4.899 (5.303% bad). Conclusion: Image quality, in terms of HU accuracy, in the presence of high-Z metal objects in CT scans is improved by metal artifact reduction reconstruction algorithms. The MDT algorithm had the highest HU value accuracy (RMSE=10.05 HU) and best streak severity metric, but scored the worst in terms of geometric accuracy. Qualitatively, the MAR and MDT algorithms increased detectability of inserts

  8. SU-F-J-175: Evaluation of Metal Artifact Reduction Algorithms in Computed Tomography and Their Application to Radiation Therapy Treatment Planning

    Energy Technology Data Exchange (ETDEWEB)

    Norris, H; Rangaraj, D; Kim, S [Baylor Scott & White Health, Temple, TX (United States)

    2016-06-15

    Purpose: High-Z (metal) implants in CT scans cause significant streak-like artifacts in the reconstructed dataset. This results in both inaccurate CT Hounsfield units for the tissue as well as obscuration of the target and organs at risk (OARs) for radiation therapy planning. Herein we analyze two metal artifact reduction algorithms: GE’s Smart MAR and a Metal Deletion Technique (MDT) for geometric and Hounsfield Unit (HU) accuracy. Methods: A CT-to-electron density phantom, with multiple inserts of various densities and a custom Cerrobend insert (Zeff=76.8), is utilized in this continuing study. The phantom is scanned without metal (baseline) and again with the metal insert. Using one set of projection data, reconstructed CT volumes are created with filtered-back-projection (FBP) and the MAR and the MDT algorithms. Regions-of-Interest (ROIs) are evaluated for each insert for HU accuracy; the metal insert’s Full-Width-Half-Maximum (FWHM) is used to evaluate the geometric accuracy. Streak severity is quantified with an HU error metric over the phantom volume. Results: The original FBP reconstruction has a Root-Mean-Square-Error (RMSE) of 57.55 HU (STD=29.19, range=−145.8 to +79.2) compared to baseline. The MAR reconstruction has a RMSE of 20.98 HU (STD=13.92, range=−18.3 to +61.7). The MDT reconstruction has a RMSE of 10.05 HU (STD=10.5, range=−14.8 to +18.6). FWHM for baseline=162.05; FBP=161.84 (−0.13%); MAR=162.36 (+0.19%); MDT=162.99 (+0.58%). Streak severity metric for FBP=19.73 (22.659% bad pixels); MAR=8.743 (9.538% bad); MDT=4.899 (5.303% bad). Conclusion: Image quality, in terms of HU accuracy, in the presence of high-Z metal objects in CT scans is improved by metal artifact reduction reconstruction algorithms. The MDT algorithm had the highest HU value accuracy (RMSE=10.05 HU) and best streak severity metric, but scored the worst in terms of geometric accuracy. Qualitatively, the MAR and MDT algorithms increased detectability of inserts

  9. Effects of chronic intraventricular infusion of heparin glycosaminoglycan on learning and brain acetylcholine parameters in aged rats

    Czech Academy of Sciences Publication Activity Database

    Ježek, Karel; Schulz, D.; De Souza Silva, M. A.; Müller, H. W.; Huston, J. P.; Hasenöhrl, R. U.

    2003-01-01

    Roč. 147, 1-2 (2003), s. 115-123 ISSN 0166-4328 Grant - others:Deutsche Forschungsgemeinschaft(DE) HU 306/11-3 Institutional research plan: CEZ:AV0Z5011922 Keywords : heparin * memory * ageing Subject RIV: FH - Neurology Impact factor: 2.817, year: 2003

  10. Noise Reduction with Microphone Arrays for Speaker Identification

    Energy Technology Data Exchange (ETDEWEB)

    Cohen, Z

    2011-12-22

    Reducing acoustic noise in audio recordings is an ongoing problem that plagues many applications. This noise is hard to reduce because of interfering sources and non-stationary behavior of the overall background noise. Many single channel noise reduction algorithms exist but are limited in that the more the noise is reduced; the more the signal of interest is distorted due to the fact that the signal and noise overlap in frequency. Specifically acoustic background noise causes problems in the area of speaker identification. Recording a speaker in the presence of acoustic noise ultimately limits the performance and confidence of speaker identification algorithms. In situations where it is impossible to control the environment where the speech sample is taken, noise reduction filtering algorithms need to be developed to clean the recorded speech of background noise. Because single channel noise reduction algorithms would distort the speech signal, the overall challenge of this project was to see if spatial information provided by microphone arrays could be exploited to aid in speaker identification. The goals are: (1) Test the feasibility of using microphone arrays to reduce background noise in speech recordings; (2) Characterize and compare different multichannel noise reduction algorithms; (3) Provide recommendations for using these multichannel algorithms; and (4) Ultimately answer the question - Can the use of microphone arrays aid in speaker identification?

  11. Neutralisation of the anti-coagulant effects of heparin by histones in blood plasma and purified systems.

    Science.gov (United States)

    Longstaff, Colin; Hogwood, John; Gray, Elaine; Komorowicz, Erzsebet; Varjú, Imre; Varga, Zoltán; Kolev, Krasimir

    2016-03-01

    Neutrophil extracellular traps (NETs) composed primarily of DNA and histones are a link between infection, inflammation and coagulation. NETs promote coagulation and approaches to destabilise NETs have been explored to reduce thrombosis and treat sepsis. Heparinoids bind histones and we report quantitative studies in plasma and purified systems to better understand physiological consequences. Unfractionated heparin (UFH) was investigated by activated partial thromboplastin time (APTT) and alongside low-molecular-weight heparins (LMWH) in purified systems with thrombin or factor Xa (FXa) and antithrombin (AT) to measure the sensitivity of UFH or LMWH to histones. A method was developed to assess the effectiveness of DNA and non-anticoagulant heparinoids as anti-histones. Histones effectively neutralised UFH, the IC50 value for neutralisation of 0.2 IU/ml UFH was 1.8 µg/ml histones in APTT and 4.6 µg/ml against 0.6 IU/ml UFH in a purified system. Histones also inhibited the activities of LMWHs with thrombin (IC50 6.1 and 11.0 µg/ml histones, for different LMWHs) or FXa (IC50 7.8 and 7.0 µg/ml histones). Direct interactions of UFH and LMWH with DNA and histones were explored by surface plasmon resonance, while rheology studies showed complex effects of histones, UFH and LMWH on clot resilience. A conclusion from these studies is that anticoagulation by UFH and LMWH will be compromised by high affinity binding to circulating histones even in the presence of DNA. A complete understanding of the effects of histones, DNA and heparins on the haemostatic system must include an appreciation of direct effects on fibrin and clot structure.

  12. Totally parallel multilevel algorithms

    Science.gov (United States)

    Frederickson, Paul O.

    1988-01-01

    Four totally parallel algorithms for the solution of a sparse linear system have common characteristics which become quite apparent when they are implemented on a highly parallel hypercube such as the CM2. These four algorithms are Parallel Superconvergent Multigrid (PSMG) of Frederickson and McBryan, Robust Multigrid (RMG) of Hackbusch, the FFT based Spectral Algorithm, and Parallel Cyclic Reduction. In fact, all four can be formulated as particular cases of the same totally parallel multilevel algorithm, which are referred to as TPMA. In certain cases the spectral radius of TPMA is zero, and it is recognized to be a direct algorithm. In many other cases the spectral radius, although not zero, is small enough that a single iteration per timestep keeps the local error within the required tolerance.

  13. A New Block Processing Algorithm of LLL for Fast High-dimension Ambiguity Resolution

    Directory of Open Access Journals (Sweden)

    LIU Wanke

    2016-02-01

    Full Text Available Due to high dimension and precision for the ambiguity vector under GNSS observations of multi-frequency and multi-system, a major problem to limit computational efficiency of ambiguity resolution is the longer reduction time when using conventional LLL algorithm. To address this problem, it is proposed a new block processing algorithm of LLL by analyzing the relationship between the reduction time and the dimensions and precision of ambiguity. The new algorithm reduces the reduction time to improve computational efficiency of ambiguity resolution, which is based on block processing ambiguity variance-covariance matrix that decreased the dimensions of single reduction matrix. It is validated that the new algorithm with two groups of measured data. The results show that the computing efficiency of the new algorithm increased by 65.2% and 60.2% respectively compared with that of LLL algorithm when choosing a reasonable number of blocks.

  14. Ergotism of the lower limb complicating DHE-heparin thrombosis prophylaxis. Observation by serial angiography

    Energy Technology Data Exchange (ETDEWEB)

    Warmuth-Metz, M.

    1988-10-01

    Today ergotism is becoming more and more important as a complication in the treatment of migraine headache or thrombosis prophylaxis with DHE heparin. Although complete recovery is seldom reported in the current literature, in our case it was possible to resolve a spasm of the left lower limb completely by early diagnosis and adaequate pharmacological treatment. The case was well documented by serial angiography.

  15. Use of transsplenic injection of agitated saline and heparinized blood for the ultrasonographic diagnosis of macroscopic portosystemic shunts in dogs.

    Science.gov (United States)

    Gómez-Ochoa, Pablo; Llabrés-Díaz, Francisco; Ruiz, Sergio; Corda, Andrea; Prieto, Saul; Sosa, Ivan; Gregori, Tommaso; Gascón, Manuel; Couto, Guillermo C

    2011-01-01

    We describe the use of ultrasonography-guided percutaneous splenic injection of agitated saline and heparinized blood for the diagnosis of portosystemic shunts (PSS) in 34 dogs. Agitated saline mixed with 1 ml of heparinized autologous blood was injected into the spleen of 34 sedated dogs under sonographic guidance. The transducer was then sequentially repositioned to visualize the portal vein, the caudal vena cava, and the right atrium through different acoustic windows. It was possible to differentiate between intrahepatic and extrahepatic shunts depending on the entry point of the microbubbles into the caudal vena cava. Portoazygos shunts and portocaval shunts could be differentiated based on the presence of microbubbles in the caudal vena cava and/or the right atrium. In one dog, collateral circulation due to portal hypertension was identified. In dogs with a single extrahepatic shunt, the microbubbles helped identify the shunting vessel. The technique was also used postoperatively to assess the efficacy of shunt closure. All abnormal vessels were confirmed by exploratory laparotomy or with ultrasonographic identification of the shunting vessel. Ultrasound-guided transsplenic injection of agitated saline with heparinized blood should be considered as a valuable technique for the diagnosis of PSS; it is easy to perform, safe, and the results are easily reproducible.

  16. A Robust Computational Technique for Model Order Reduction of Two-Time-Scale Discrete Systems via Genetic Algorithms

    Directory of Open Access Journals (Sweden)

    Othman M. K. Alsmadi

    2015-01-01

    Full Text Available A robust computational technique for model order reduction (MOR of multi-time-scale discrete systems (single input single output (SISO and multi-input multioutput (MIMO is presented in this paper. This work is motivated by the singular perturbation of multi-time-scale systems where some specific dynamics may not have significant influence on the overall system behavior. The new approach is proposed using genetic algorithms (GA with the advantage of obtaining a reduced order model, maintaining the exact dominant dynamics in the reduced order, and minimizing the steady state error. The reduction process is performed by obtaining an upper triangular transformed matrix of the system state matrix defined in state space representation along with the elements of B, C, and D matrices. The GA computational procedure is based on maximizing the fitness function corresponding to the response deviation between the full and reduced order models. The proposed computational intelligence MOR method is compared to recently published work on MOR techniques where simulation results show the potential and advantages of the new approach.

  17. A flexibility-based method via the iterated improved reduction system and the cuckoo optimization algorithm for damage quantification with limited sensors

    International Nuclear Information System (INIS)

    Zare Hosseinzadeh, Ali; Ghodrati Amiri, Gholamreza; Bagheri, Abdollah; Koo, Ki-Young

    2014-01-01

    In this paper, a novel and effective damage diagnosis algorithm is proposed to localize and quantify structural damage using incomplete modal data, considering the existence of some limitations in the number of attached sensors on structures. The damage detection problem is formulated as an optimization problem by computing static displacements in the reduced model of a structure subjected to a unique static load. The static responses are computed through the flexibility matrix of the damaged structure obtained based on the incomplete modal data of the structure. In the algorithm, an iterated improved reduction system method is applied to prepare an accurate reduced model of a structure. The optimization problem is solved via a new evolutionary optimization algorithm called the cuckoo optimization algorithm. The efficiency and robustness of the presented method are demonstrated through three numerical examples. Moreover, the efficiency of the method is verified by an experimental study of a five-story shear building structure on a shaking table considering only two sensors. The obtained damage identification results for the numerical and experimental studies show the suitable and stable performance of the proposed damage identification method for structures with limited sensors. (paper)

  18. Efficient algorithms of multidimensional γ-ray spectra compression

    International Nuclear Information System (INIS)

    Morhac, M.; Matousek, V.

    2006-01-01

    The efficient algorithms to compress multidimensional γ-ray events are presented. Two alternative kinds of compression algorithms based on both the adaptive orthogonal and randomizing transforms are proposed. In both algorithms we employ the reduction of data volume due to the symmetry of the γ-ray spectra

  19. Changes in perfusion scintigraphy in the first days of heparin therapy in patients with acute pulmonary embolism

    NARCIS (Netherlands)

    de Groot, M. R.; Oostdijk, A. H.; Engelage, A. H.; van Marwijk Kooy, M.; Büller, H. R.

    2000-01-01

    Patients with suspected pulmonary embolism often receive heparin therapy for hours to days before ventilation/perfusion scintigraphy is completed. We assessed to what extent the lung scan classification and pulmonary vascular perfusion changed over a period of 2-4 days of full anticoagulant therapy.

  20. Analysis of Individual Preferences for Tuning Noise-Reduction Algorithms

    NARCIS (Netherlands)

    Houben, Rolph; Dijkstra, Tjeerd M. H.; Dreschler, Wouter A.

    2012-01-01

    There is little research on user preference for different settings of noise reduction, especially for individual users. We therefore measured individual preferences for pairs of audio streams differing in the trade-off between noise reduction and speech distortion. A logistic probability model was