WorldWideScience

Sample records for hemodialysis catheter insertion

  1. Insertion of central venous catheters for hemodialysis using angiographic techniques in patients with previous multiple catheterizations

    Energy Technology Data Exchange (ETDEWEB)

    Kotsikoris, Ioannis, E-mail: gkotsikoris@gmail.com [Department of Vascular Surgery, “Erythros Stauros” General Hospital (Greece); Zygomalas, Apollon, E-mail: azygomalas@upatras.gr [Department of General Surgery, University Hospital of Patras (Greece); Papas, Theofanis, E-mail: pfanis@otenet.gr [Department of Vascular Surgery, “Erythros Stauros” General Hospital (Greece); Maras, Dimitris, E-mail: dimmaras@gmail.com [Department of Vascular Surgery, “Erythros Stauros” General Hospital (Greece); Pavlidis, Polyvios, E-mail: polpavlidis@yahoo.gr [Department of Vascular Surgery, “Erythros Stauros” General Hospital (Greece); Andrikopoulou, Maria, E-mail: madric@gmail.com [Department of Vascular Surgery, “Erythros Stauros” General Hospital (Greece); Tsanis, Antonis, E-mail: atsanis@gmail.com [Department of Interventional Radiology, “Erythros Stauros” General Hospital (Greece); Alivizatos, Vasileios, E-mail: valiviz@hol.gr [Department of General Surgery and Artificial Nutrition Unit, “Agios Andreas” General Hospital of Patras (Greece); Bessias, Nikolaos, E-mail: bessias@otenet.gr [Department of Vascular Surgery, “Erythros Stauros” General Hospital (Greece)

    2012-09-15

    Introduction: Central venous catheter placement is an effective alternative vascular access for dialysis in patients with chronic renal failure. The purpose of this study was to evaluate the insertion of central venous catheters for hemodialysis using angiographic techniques in patients with previous multiple catheterizations in terms of efficacy of the procedure and early complications. Materials and methods: Between 2008 and 2010, the vascular access team of our hospital placed 409 central venous catheters in patients with chronic renal failure. The procedure was performed using the Seldinger blind technique. In 18 (4.4%) cases it was impossible to advance the guidewire, and so the patients were transported to the angiography suite. Results: Using the angiographic technique, the guidewire was advanced in order to position the central venous catheter. The latter was inserted into the subclavian vein in 12 (66.6%) cases, into the internal jugular vein in 4 (22.2%) and into the femoral vein in 2 (11.1%) cases. There was only one complicated case with severe arrhythmia in 1 (5.5%) patient. Conclusion: Our results suggest that insertion of central venous catheters using angiographic techniques in hemodialysis patients with previous multiple catheterizations is a safe and effective procedure with few complications and high success rates.

  2. Insertion of central venous catheters for hemodialysis using angiographic techniques in patients with previous multiple catheterizations

    International Nuclear Information System (INIS)

    Kotsikoris, Ioannis; Zygomalas, Apollon; Papas, Theofanis; Maras, Dimitris; Pavlidis, Polyvios; Andrikopoulou, Maria; Tsanis, Antonis; Alivizatos, Vasileios; Bessias, Nikolaos

    2012-01-01

    Introduction: Central venous catheter placement is an effective alternative vascular access for dialysis in patients with chronic renal failure. The purpose of this study was to evaluate the insertion of central venous catheters for hemodialysis using angiographic techniques in patients with previous multiple catheterizations in terms of efficacy of the procedure and early complications. Materials and methods: Between 2008 and 2010, the vascular access team of our hospital placed 409 central venous catheters in patients with chronic renal failure. The procedure was performed using the Seldinger blind technique. In 18 (4.4%) cases it was impossible to advance the guidewire, and so the patients were transported to the angiography suite. Results: Using the angiographic technique, the guidewire was advanced in order to position the central venous catheter. The latter was inserted into the subclavian vein in 12 (66.6%) cases, into the internal jugular vein in 4 (22.2%) and into the femoral vein in 2 (11.1%) cases. There was only one complicated case with severe arrhythmia in 1 (5.5%) patient. Conclusion: Our results suggest that insertion of central venous catheters using angiographic techniques in hemodialysis patients with previous multiple catheterizations is a safe and effective procedure with few complications and high success rates

  3. Non-imaging assisted insertion of un-cuffed, non-tunneled internal jugular venous catheters for hemodialysis: Safety and utility in modern day world

    Directory of Open Access Journals (Sweden)

    Manish Rathi

    2016-08-01

    Full Text Available Background: Absolute necessity in acute kidney injury (AKI and ignorance in chronic kidney disease (CKD make the use of un-cuffed, non-tunneled catheters an indispensable vascular access for hemodialysis. Although these catheters should be inserted under radiological guidance, it may not be feasible in certain circumstances. The aim of the present study was to evaluate safety and outcome of non-imaging assisted insertion of these catheters in internal jugular vein (IJV for hemodialysis. Methods: We analyzed 233 attempts of non-imaging assisted un-cuffed, non-tunneled IJV catheterization at our center. The immediate insertion complications, duration of use, rate and type of infection and other complications were assessed. Results: Out of the 233 attempts, 223 (213-right, 10-left were successful. The most common indication was AKI (n = 127, 54.5%, followed by CKD (n = 99, 42.5%. Successful catheterization at first attempt was achieved in 78.9%. Insertion complications were noted in 12.8% and included arterial puncture (5.2%, hematoma (3.0% and malposition (2.1%. Amongst 219 catheters followed for 4825 days, the mean duration of use was 22 days. Catheter related infections occurred in 42 patients with an incidence of 8.7 per 1000 catheter days. Bacteraemia was present in 10/36 cases (27.7%, positive catheter tip cultures in 71.4% cases and staphylococcal species were the most common organism. Cumulative hazard analysis by Cox regression revealed a linear increase in the risk for infection with each week. Conclusion: Non-imaging assisted insertion of uncuffed, non-tunneled catheters is associated with slightly higher rate of insertion complication but comparable outcome in terms of infection rate or days of use. Keywords: Hemodialysis, Internal jugular vein catheterization, Catheter related infection

  4. Mitral and aortic valve endocarditis together with mitral cleft developing due to an incorrectly inserted permanent hemodialysis catheter

    Directory of Open Access Journals (Sweden)

    Oktay Şenöz

    2015-06-01

    Full Text Available Infective endocarditis (IE usually affects the right-sided valves in hemodialysis (HD patients. Hemodialysis catheter-related left-sided endocarditis is a very rare condition and has a high mortality. A 58-year-old male patient who had been inserted a permanent HD catheter from the right subclavian vein 6 months ago was admitted with fever and dyspnea. Transesophageal echocardiography (TEE revealed that the HD catheter extended to the left atrium by passing from interatrial septum (IAS. A vegetation in the interatrial septum, aortic valve, which formed a perforation in the mitral valve and leading to severe valve insufficiency was observed. The patient was planned to undergo an operation however he died as a result of impaired hemodynamic stability. Catheter site should be confirmed through an imaging method performed during or after the procedure in order to prevent catheter malposition. A proper antibiotic treatment should be started as soon as a catheter-related endocarditis is detected, a surgical decision should be done in the shortest and the most proper time.

  5. Central venous catheter insertion problem solving using intravenous catheter: technical communication

    Directory of Open Access Journals (Sweden)

    Alemohammad M

    2013-02-01

    Full Text Available Insertion of central venous catheter is an accepted method for hemodynamic monitor-ring, drug and fluid administration, intravenous access, hemodialysis and applying cardiac pace-maker in hospitalized patients. This procedure can be associated with severe complications. The aim of this article is to provide a practical approach to prevent catheter malposition in states that the guide wire will not pass freely.During central venous insertion in internal jugular vein using modified seldinger technique, when after venous insertion, the passage of the guide wire shows difficulties and don’t pass freely, insertion of an intravenous cannula over the wire and re-insertion of the wire can help to prevent malposition of the wire and the catheter. Use of an intravenous cannula over the guide, in situations that the guide wire cannot pass freely among the needle inserted in internal jugular vein, and re-insertion of the guide can probably prevent or reduce the tissue or vascular trauma and the associated complica-tions. This simple maneuver can be helpful in difficult cases especially in cardiac surgery patients who receive high dose heparin and it is necessary to avoid traumatize-tion of carotid artery.

  6. Thrombosis caused by polyurethane double-lumen subclavian superior vena cava catheter and hemodialysis

    DEFF Research Database (Denmark)

    Wanscher, Maria Rørbæk; Frifelt, J J; Smith-Sivertsen, C

    1988-01-01

    During an 18-month period, 82 consecutive patients (37 women and 45 men), with a mean age of 50 yr (range 15 to 74), underwent hemodialysis with 91 polyurethane double-lumen subclavian superior vena cava catheters inserted via the right subclavian vein. Upon catheter removal, venograms were...

  7. Previous PICC Placement May Be Associated With Catheter-Related Infections in Hemodialysis Patients

    International Nuclear Information System (INIS)

    Butler, Philip J.; Sood, Shreya; Mojibian, Hamid; Tal, Michael G.

    2011-01-01

    Background: Catheter-related infections (CRIs) are a significant source of morbidity and mortality in hemodialysis patients. The identification of novel, modifiable risk factors for CRIs may lead to improved outcomes in this population. Peripherally inserted central catheters (PICCs) have been hypothesized to compromise vascular access due to vascular damage and venous thrombosis, whereas venous thrombosis has been linked to the development of CRIs. Here we examine the association between PICC placement and CRIs. Methods: A retrospective review was performed of all chronic hemodialysis catheter placements and exchanges performed at a large university hospital from September 2003 to September 2008. History of PICC line use was determined by examining hospital radiologic records from December 1993 to September 2008. Catheter-related complications were assessed and correlated with PICC line history. Results: One hundred eighty-five patients with 713 chronic tunneled hemodialysis catheter placements were identified. Thirty-eight of those patients (20.5%) had a history of PICC placement; these patients were more likely to have CRIs (odds ratio = 2.46, 95% confidence interval = 1.71–3.53, p < .001) compared with patients without a history of PICC placement. There was no difference between the two groups in age or number of catheters placed. Conclusion: Previous PICC placement may be associated with catheter-related infections in hemodialysis patients.

  8. Patency of Femoral Tunneled Hemodialysis Catheters and Factors Predictive of Patency Failure

    International Nuclear Information System (INIS)

    Burton, Kirsteen R.; Guo, Lancia L. Q.; Tan, Kong T.; Simons, Martin E.; Sniderman, Kenneth W.; Kachura, John R.; Beecroft, John R.; Rajan, Dheeraj K.

    2012-01-01

    Purpose: To determine the patency rates of and factors associated with increased risk of patency failure in patients with femoral vein tunneled hemodialysis catheters. Methods: All femoral tunneled catheter insertions from 1996 to 2006 were reviewed, during which time 123 catheters were inserted. Of these, 66 were exchanges. Patients with femoral catheter failure versus those with femoral catheter patency were compared. Confounding factors, such as demographic and procedural factors, were incorporated and assessed using univariate and multivariable Cox proportional hazards regression analyses. Results: Mean catheter primary patency failure time was 96.3 days (SE 17.9 days). Primary patency at 30, 60, 90, and 180 days was 53.8%, 45.4%, 32.1%, and 27.1% respectively. Crude rates of risk of catheter failure did not suggest a benefit for patients receiving catheters introduced from one side versus the other, but more cephalad location of catheter tip was associated with improved patency. Multivariate analysis showed that patients whose catheters were on the left side (p = 0.009), were of increasing age at the time of insertion (p = 0.002) and that those who had diabetes (p = 0.001) were at significantly greater risk of catheter failure. The catheter infection rate was 1.4/1000 catheter days. Conclusion: Patients who were of a more advanced age and had diabetes were at greater risk of femoral catheter failure, whereas those who received femoral catheters from the right side were less at risk of catheter failure.

  9. Central vein perforation during tunneled dialysis catheter insertion: principles of acute management.

    Science.gov (United States)

    Pua, Uei

    2014-10-01

    Central venous perforation during dialysis catheter insertion is a potentially fatal complication. Prompt recognition and judicious initial steps are important in optimizing the outcome. The purpose of this manuscript is to illustrate the imaging features and steps in initial management. © 2014 International Society for Hemodialysis.

  10. Impact of short-term hemodialysis catheters on the central veins: a catheter venographic study

    Energy Technology Data Exchange (ETDEWEB)

    Oguzkurt, Levent E-mail: loguzkurt@yahoo.com; Tercan, Fahri; Torun, Dilek; Yildirim, Tuelin; Zuemruetdal, Ayseguel; Kizilkilic, Osman

    2004-12-01

    Objective: To determine the incidence of pericatheter sleeve formation, thrombus formation, and stenosis of the central veins in hemodialysis patients with temporary catheters. Methods and material: In this prospective study, 57 patients (40 males, 17 females) with temporary dialysis catheters had catheter venography by pulling back the catheter just before removal. Patient's age range was 25-87 years (mean age, 51 years). The venographic studies were evaluated for pericatheter sleeve formation, thrombus formation, and stenosis of the brachiocephalic vein (BCV) and the superior vena cava (SVC). The IJV could only be evaluated if there was adequate filling during contrast administration. In a subgroup of patients who had had only right IJV or only right SCV catheters, impact of these catheters on the central veins was compared. Results: The catheter location was right internal jugular vein (IJV) in 26 cases, right subclavian vein (SCV) in 27 cases, left IJV in 1 case, and left SCV in 3 cases. Thirty-two patients (56%) had had only one temporary catheter and the rest had had more than one inserted. The mean dwell time for the catheters was 21 days (range 7-59 days). A pericatheter sleeve was detected on venography in 32 (56%) patients and thrombus formation was noted in 16 patients (28%). A total of 41 patients (72%) exhibited pericatheter sleeve and/or thrombus formation. While 19 of the 32 patients (59%) without previous catheterization had a sleeve around the catheter, only 13 (52%) of 25 patients who had had multiple catheters inserted had a sleeve (P>0.05). Of the eight patients (14%) with BCV stenosis, two had >50% stenosis. Only one patient (2%) had mild stenosis of the SVC. Three patients out of 15 (20%) who had diagnostic venography for the IJV had severe stenosis of the vein. Pericatheter sleeve formation was more frequent in women (P<0.05). However, there were no statistical differences with respect to pericatheter sleeve formation, luminal filling

  11. [Fistulae or catheter for elderly who start hemodialysis without permanent vascular access?].

    Science.gov (United States)

    García Cortés, Ma J; Viedma, G; Sánchez Perales, M C; Borrego, F J; Borrego, J; Pérez del Barrio, P; Gil Cunquero, J M; Liébana, A; Pérez Bañasco, V

    2005-01-01

    Autologous access is the best vascular access for dialysis also in older patients and it should be mature when patient needs hemodialysis. It is not always possible. Surgeon availability and demographic characteristics of patients (age, diabetes, vascular disease...) are factors that determine primary vascular access. To analyse outcome and vascular access complications in elderly who start hemodialysis without vascular access. All patients older than 75 years who initiated hemodialysis without vascular access between January 2000 and June 2002 were included, They were divided en two groups depending on primary vascular access. GI: arterio-venous fistulae. GIIl: Tunnelled cuffed catheter. Epidemiological and analytical data, vascular access complications related, as well as patient and first permanent vascular access survival from their inclusion in dialysis up to December 2002 were analysed and compared in both groups. 32 patients were studied. GI: n = 17 (4 men) and GIIl: n =1 5 (8 men), age: 79.9 +/- 3.8 and 81.7 +/- 4 years respectively (ns). There were no differences in sex and comorbidity (diabetes, ischemic heart disease, peripheral vascular disease and hypertension). It took GI 3 months to get a permanent vascular access suitable for using, while it took GIIl 1.3 months (p catheters was higher in GI (3.35 vs 1.87 p central venous thrombosis happen in GI (I: 25 CVT/100 patients-year) vs 30% in GIIl (I = 14.4/100 patients-year) (ns). No significant differences neither in bleeding (66.7% vs 33.3%) nor ischemia (75% vs 25%) were found. Dialysis dose (Kt/V) as well as anaemia degree were similar in both groups. Permanent vascular access survival after 2 years was 45.8% in GI and 24% in GII (ns). Patient survival was similar in GI and GII (72% vs 51% ns). Elderly who start hemodialysis without vascular access took longer to get a suitable permanent vascular access when arterio-venous fistulae is placed than with a tunnelled cuffed hemodialysis catheter. As a

  12. Hemodialysis Catheter Heat Transfer for Biofilm Prevention and Treatment.

    Science.gov (United States)

    Richardson, Ian P; Sturtevant, Rachael; Heung, Michael; Solomon, Michael J; Younger, John G; VanEpps, J Scott

    2016-01-01

    Central line-associated bloodstream infections (CLABSIs) are not easily treated, and many catheters (e.g., hemodialysis catheters) are not easily replaced. Biofilms (the source of infection) on catheter surfaces are notoriously difficult to eradicate. We have recently demonstrated that modest elevations of temperature lead to increased staphylococcal susceptibility to vancomycin and significantly soften the biofilm matrix. In this study, using a combination of microbiological, computational, and experimental studies, we demonstrate the efficacy, feasibility, and safety of using heat as an adjuvant treatment for infected hemodialysis catheters. Specifically, we show that treating with heat in the presence of antibiotics led to additive killing of Staphylococcus epidermidis with similar trends seen for Staphylococcus aureus and Klebsiella pneumoniae. The magnitude of temperature elevation required is relatively modest (45-50°C) and similar to that used as an adjuvant to traditional cancer therapy. Using a custom-designed benchtop model of a hemodialysis catheter, positioned with tip in the human vena cava as well as computational fluid dynamic simulations, we demonstrate that these temperature elevations are likely achievable in situ with minimal increased in overall blood temperature.

  13. Transhepatic venous catheters for hemodialysis

    Directory of Open Access Journals (Sweden)

    Mohamed El Gharib

    2014-06-01

    Conclusion: Based on our findings, transhepatic hemodialysis catheters have proven to achieve good long-term functionality. A high level of maintenance is required to preserve patency, although this approach provides remarkably durable access for patients who have otherwise exhausted access options.

  14. Incidence of catheter-related complications in patients with central venous or hemodialysis catheters: a health care claims database analysis.

    Science.gov (United States)

    Napalkov, Pavel; Felici, Diana M; Chu, Laura K; Jacobs, Joan R; Begelman, Susan M

    2013-10-16

    Central venous catheter (CVC) and hemodialysis (HD) catheter usage are associated with complications that occur during catheter insertion, dwell period, and removal. This study aims to identify and describe the incidence rates of catheter-related complications in a large patient population in a United States-based health care claims database after CVC or HD catheter placement. Patients in the i3 InVision DataMart® health care claims database with at least 1 CVC or HD catheter insertion claim were categorized into CVC or HD cohorts using diagnostic and procedural codes from the US Renal Data System, American College of Surgeons, and American Medical Association's Physician Performance Measures. Catheter-related complications were identified using published diagnostic and procedural codes. Incidence rates (IRs)/1000 catheter-days were calculated for complications including catheter-related bloodstream infections (CRBSIs), thrombosis, embolism, intracranial hemorrhage (ICH), major bleeding (MB), and mechanical catheter-related complications (MCRCs). Thirty percent of the CVC cohort and 54% of the HD cohort had catheter placements lasting <90 days. Catheter-related complications occurred most often during the first 90 days of catheter placement. IRs were highest for CRBSIs in both cohorts (4.0 [95% CI, 3.7-4.3] and 5.1 [95% CI, 4.7-5.6], respectively). Other IRs in CVC and HD cohorts, respectively, were thrombosis, 1.3 and 0.8; MCRCs, 0.6 and 0.7; embolism, 0.4 and 0.5; MB, 0.1 and 0.3; and ICH, 0.1 in both cohorts. Patients with cancer at baseline had significantly higher IRs for CRBSIs and thrombosis than non-cancer patients. CVC or HD catheter-related complications were most frequently seen in patients 16 years or younger. The risk of catheter-related complications is highest during the first 90 days of catheter placement in patients with CVCs and HD catheters and in younger patients (≤16 years of age) with HD catheters. Data provided in this study can be applied

  15. Radiologic placement of hemodialysis central venous catheters: a practical guide

    Energy Technology Data Exchange (ETDEWEB)

    Schemmer, D.; Sadler, D.J.; Gray, R.R.; Saliken, J.C.; So, C.B. [Foothills Hospital, Dept. of Diagnostic Imaging, Calgary, Alberta (Canada)

    2001-04-01

    Typical indications for central venous catheters (CVCs) are hemodialysis (HD), apheresis, total parenteral nutrition, analgesia, chemotherapy, long-term antibiotic therapy and cases of difficult or absent peripheral venous access. One of the largest medical services requesting CVC insertion is nephrology for HD patients. Demographics dictate that the demand for CVCs will continue to grow over the next few decades, placing striking demands on interventional radiology departments. In our centre, interventional radiologists now place nearly all percutaneously inserted HD CVCs. Radiologists provide rapid access to CVC services with significantly fewer complications than CVCs placed by other clinicians. With the demand for CVC management increasing and available operating room time decreasing, many clinicians now refer CVC insertions to radiologists. As well, clinicians who ordinarily place their own lines often refer high-risk patients, such as those who are obese or uncooperative and those with burns or coagulopathy. Our experience, derived from over 7000 CVC insertions, manipulations and removals, has allowed us to continually progress and improve our techniques, many of which are summarized here. (author)

  16. Catheter-related fungal endocarditis caused by Candida parapsilosis in a hemodialysis patient.

    Science.gov (United States)

    Shu, Ying; Yu, Shaobin; Zha, Ling; Fu, Ping; Cui, Tianlei

    2017-10-01

    Fungal endocarditis (FE) is commonly regarded as a rare but fatal disease. The incidence of infective endocarditis (IE) in hemodialysis (HD) patients is thought to be obviously higher than that in the general population. Moreover, IE occurs more likely in HD patients with catheters. With the increase of HD population and extensive use of catheters in HD patients, FE, as a special form of IE, may increase and bring new challenges to clinicians. We reported a case of FE associated with catheter infection in a 44-year-old woman on HD. The risk factors and treatment strategies of FE in HD patients were discussed. © 2017 International Society for Hemodialysis.

  17. Radiological Tenckhoff catheter insertion for peritoneal dialysis: A cost-effective approach.

    Science.gov (United States)

    Lee, James; Mott, Nigel; Mahmood, Usman; Clouston, John; Summers, Kara; Nicholas, Pauline; Gois, Pedro Henrique França; Ranganathan, Dwarakanathan

    2018-04-01

    Radiological insertion of Tenckhoff catheters can be an alternative option for peritoneal dialysis access creation, as compared to surgical catheter insertion. This study will review the outcomes and complications of radiological Tenckhoff catheter insertion in a metropolitan renal service and compare costs between surgical and radiological insertion. Data were collected prospectively for all patients who had a Tenckhoff catheter insertion for peritoneal dialysis (PD) under radiological guidance at our hospital from May 2014 to November 2016. The type of catheter used and complications, including peri-catheter leak, exit site infection and peritonitis were reviewed. Follow-up data were also collected at points 3, 6 and 12 months from catheter insertion. Costing data were obtained from Queensland Health Electronic Reporting System (QHERS) data, average staff salaries and consumable contract price lists. In the 30-month evaluation period, 70 catheters were inserted. Two patients had an unsuccessful procedure due to the presence of abdominal adhesions. Seven patients had an episode of peri-catheter leak, and four patients had an exit site infection following catheter insertion. Peritonitis was observed in nine patients during the study period. The majority of patients (90%) remained on peritoneal dialysis at 3-month follow-up. The average costs of surgical and radiological insertion were noted to be AUD$7788.34 and AUD$1597.35, respectively. Radiological Tenckhoff catheter insertion for peritoneal dialysis appears to be an attractive and cost-effective option given less waiting periods for the procedure, the relatively low cost of insertion and comparable rates of complications. © 2017 The Royal Australian and New Zealand College of Radiologists.

  18. Nursing care of indwelling catheter thrombolysis for acute thrombosis in the arteriovenous fistula in hemodialysis patients

    International Nuclear Information System (INIS)

    Gao Peizhu; Ding Wenbin; Ming Zhibing; Sun Juyun

    2010-01-01

    Objective: To summarize the experience of the nursing care of indwelling catheter thrombolysis for acute thrombosis in the arteriovenous fistula in eight hemodialysis patients. Methods: After breaking thrombus through indwelling catheter, both bolus injection and micro-pump continuous infusion of urokinase was employed in eight hemodialysis patients with acute thrombosis in the arteriovenous fistula. The necessary nursing measures were carried out to assist the whole therapeutic procedure. Results: All the patients could well cooperate with the procedure of indwelling catheter thrombolysis and urokinase infusion. The reopening rate of the obstructed fistula was 100%. Conclusion: Indwelling catheter thrombolysis with urokinase infusion is a simple, effective and safe treatment for acute thrombosis in the arteriovenous fistula in hemodialysis patients. In order to obtain optimal results, necessary nursing measures must be carried out. (authors)

  19. Vascular access in neonatology: peripherally inserted central catheter and peripheral venous catheter

    Directory of Open Access Journals (Sweden)

    Marcia Lienemann

    2014-04-01

    The objective of this paper is to present aspects of peripherally inserted central catheter and peripheral venous catheter, highlighting important points in choosing the type of access. For the passage of peripherally inserted central catheter is previously performing specific course necessary, while the primary indication occurs when it is necessary to access the patient's stay for a long period of time. Whereas peripheral venipuncture is the most appropriate in cases of needing an IV line quickly and safely, for the administration of fluids, blood collection, blood transfusion and other.

  20. Peripherally inserted central catheters. Guidewire versus nonguidewire use: a comparative study.

    Science.gov (United States)

    Loughran, S C; Edwards, S; McClure, S

    1992-01-01

    To date, no research articles have been published that explore the practice of using guidewires for placement of peripherally inserted central catheters. The literature contains speculations regarding the pros and cons of guidewire use. However, no studies to date have compared patient outcomes when peripherally inserted central catheter lines are inserted with and without guidewires. To examine the use of guidewires for peripherally inserted central lines, a comparative study was conducted at two acute care facilities, one using guidewires for insertion and one inserting peripherally inserted central catheter lines without guidewires. 109 catheters were studied between January 1, 1990 and January 1, 1991. The primary focus of this study was to examine whether guidewire use places patients at higher risk for catheter-related complications, particularly phlebitis. No significant differences in phlebitis rates between the two study sites were found. Other catheter-related and noncatheter-related complications were similar between the two facilities. The results of this study do not support the belief that guidewire use increases complication rates.

  1. High dose urokinase for restoration of patency of occluded permanent central venous catheters in hemodialysis patients.

    Science.gov (United States)

    Shavit, L; Lifschitz, M; Plaksin, J; Grenader, T; Slotki, I

    2010-10-01

    Catheter thrombosis is common and results in inadequate dialysis treatment and, frequently, in catheter loss. Since dialysis treatment runs on a strict schedule, occluded catheters need to be restored in a timely and cost effective manner. We present a new shortened protocol of urokinase infusion that allows hemodialysis to be performed within 90 minutes. To chronic hemodialysis patients, who developed complete catheter occlusion, urokinase was infused simultaneously through both lumens of the catheter (125,000 units to each lumen) over 90 minutes. Technical success was defined as restoring blood pump speed to at least 250 ml/min. We determined the average time from catheter placement to first clot event (primary patency PP), recurrent clot event after urokinase treatment (secondary patency SP), catheter salvage rate and cause for removal. 37 catheters developed total thrombosis and urokinase was used to restore patency one or more times (total 47 treatments). Catheter salvage rate was 97 %. The average time of PP was 152 ± 56 days (7 - 784 days). Nine patients (30%) developed recurrent occlusion and the average time of SP was 64 ± 34 days (2 - 364 days). One catheter was removed because of dysfunction due to thrombosis. Other catheters were removed due to infection, fistula maturation or fell out spontaneously. Hemodialysis was performed immediately after treatment with blood speed of 250 ml/min in all patients. Our protocol is highly effective, short, and allows to restore patency of totally occluded central venous catheters with minimal disruption of the dialysis session.

  2. Prevalence of infection in patients with temporary catheter for hemodialysis in a teaching hospital

    Directory of Open Access Journals (Sweden)

    Palmiane de Rezende Ramim Borges

    2017-08-01

    Full Text Available This study aimed to determine the prevalence of infection related to the provisional catheter for hemodialysis in a teaching hospital and evaluate the risk factors associated with these infections.  A cross-sectional study analyzed by descriptive statistics and parametric tests. It was found that out of 129 patients, 48.8 % had catheter-related infection in hemodialysis, 65 % were male, 33.3 % were 60 years old and over, and 88 % of patients were admitted to intensive care unit. The prevalence of infection in this group was high, and the vast majority of diagnoses of infection were empirical. Given this, it is suggested to establish the routine culture of the catheter tip in all cases of suspected catheter infection to improve the quality of patient care, and the relentless pursuit of the causes that trigger the infection process in line with good practice from across the healthcare team.

  3. Minimizing Hemodialysis Catheter Dysfunction: An Ounce of Prevention

    Directory of Open Access Journals (Sweden)

    Timmy Lee

    2012-01-01

    Full Text Available The maintenance of tunneled catheter (TC patency is critical for the provision of adequate hemodialysis in patients who are TC-dependent. TC dysfunction results in the need for costly and inconvenient interventions, and reduced quality of life. Since the introduction of TCs in the late 1980s, heparin catheter lock has been the standard prophylactic regimen for the prevention of TC dysfunction. More recently, alternative catheter locking agents have emerged, and in some cases have shown to be superior to heparin lock with respect to improving TC patency and reducing TC-associated infections. These include citrate, tissue plasminogen activator, and a novel agent containing sodium citrate, methylene blue, methylparaben, and propylparaben. In addition, prophylaxis using oral anticoagulants/antiplatelet agents, including warfarin, aspirin, ticlodipine, as well as the use of modified heparin-coated catheters have also been studied for the prevention of TC dysfunction with variable results. The use of oral anticoagulants and/or antiplatelet agents as primary or secondary prevention of TC dysfunction must be weighed against their potential adverse effects, and should be individualized for each patient.

  4. Preprocedural ultrasound examination versus manual palpation for thoracic epidural catheter insertion

    Directory of Open Access Journals (Sweden)

    Ahmed M Hasanin

    2017-01-01

    Conclusion: Preprocedural ultrasound imaging increased the incidence of first pass success in thoracic epidural catheter insertion and reduced the catheter insertion time compared to manual palpation method.

  5. Epidemiology, surveillance, and prevention of bloodstream infections in hemodialysis patients.

    Science.gov (United States)

    Patel, Priti R; Kallen, Alexander J; Arduino, Matthew J

    2010-09-01

    Infections cause significant morbidity and mortality in patients undergoing hemodialysis. Bloodstream infections (BSIs) are particularly problematic, accounting for a substantial number of hospitalizations in these patients. Hospitalizations for BSI and other vascular access infections appear to have increased dramatically in hemodialysis patients since 1993. These infections frequently are related to central venous catheter (CVC) use for dialysis access. Regional initiatives that have shown successful decreases in catheter-related BSIs in hospitalized patients have generated interest in replicating this success in outpatient hemodialysis populations. Several interventions have been effective in preventing BSIs in the hemodialysis setting. Avoiding the use of CVCs in favor of access types with lower associated BSI risk is among the most important. When CVCs are used, adherence to evidence-based catheter insertion and maintenance practices can positively influence BSI rates. In addition, facility-level surveillance to detect BSIs and stimulate examination of vascular access use and care practices is essential to a comprehensive approach to prevention. This article describes the current epidemiology of BSIs in hemodialysis patients and effective prevention strategies to decrease the incidence of these devastating infections.

  6. A catheter malpositioned patient with pain and paresthesia

    Directory of Open Access Journals (Sweden)

    Akbar Fadaei Haghi

    2017-01-01

    Full Text Available We report a 54-year-old woman with the history of end-stage renal disease (ESRD who was admitted to our hospital because of volume overload. Due to long-term use of peripheral veins and arteriovenous fistula (AVF failure, central venous catheterization was the only choice for hemodialysis. She developed right upper extremiti’s pain and paresis during hemodialysis. A posteroanterior chest x-ray showed the catheter tip was accidently pushed from right internal jugular vein into right subclavian vein during hemodialysis by the dialysis center nurse. Therefore, we believe that the physician should be aware of any changes in the catheter size after insertion. And a chest x-ray should ensure the catheter’s correct position in any patient who develops complications.

  7. Bedside prediction of right subclavian venous catheter insertion length

    Directory of Open Access Journals (Sweden)

    Yoon Ji Choi

    2014-12-01

    Full Text Available Background and objective: The present study aimed to evaluate whether right subclavian vein (SCV catheter insertion depth can be predicted reliably by the distances from the SCV insertion site to the ipsilateral clavicular notch directly (denoted as I-IC, via the top of the SCV arch, or via the clavicle (denoted as I-T-IC and I-C-IC, respectively. Method: In total, 70 SCV catheterizations were studied. The I-IC, I-T-IC, and I-C-IC distances in each case were measured after ultrasound-guided SCV catheter insertion. The actual length of the catheter between the insertion site and the ipsilateral clavicular notch, denoted as L, was calculated by using chest X-ray. Results: L differed from the I-T-IC, I-C-IC, and I-IC distances by 0.14±0.53, 2.19±1.17, and -0.45 ±0.68 cm, respectively. The mean I-T-IC distance was the most similar to the mean L (intraclass correlation coefficient = 0.89. The mean I-IC was significantly shorter than L, while the mean I-C-IC was significantly longer. Linear regression analysis provided the following formula: Predicted SCV catheter insertion length (cm = -0.037 + 0.036 × Height (cm + 0.903 × I-T-IC (cm (adjusted r2 =0.64. Conclusion: The I-T-IC distance may be a reliable bedside predictor of the optimal insertion length for a right SCV cannulation.

  8. Use of a National Continuing Medical Education Meeting to Provide Simulation-Based Training in Temporary Hemodialysis Catheter Insertion Skills: A Pre-Test Post-Test Study

    Directory of Open Access Journals (Sweden)

    Edward G Clark

    2014-10-01

    Full Text Available Background: Simulation-based-mastery-learning (SBML is an effective method to train nephrology fellows to competently insert temporary, non-tunneled hemodialysis catheters (NTHCs. Previous studies of SBML for NTHC-insertion have been conducted at a local level. Objectives: Determine if SBML for NTHC-insertion can be effective when provided at a national continuing medical education (CME meeting. Describe the correlation of demographic factors, prior experience with NTHC-insertion and procedural self-confidence with simulated performance of the procedure. Design: Pre-test – post-test study. Setting: 2014 Canadian Society of Nephrology annual meeting. Participants: Nephrology fellows, internal medicine residents and medical students. Measurements: Participants were surveyed regarding demographics, prior NTHC-insertion experience, procedural self-confidence and attitudes regarding the training they received. NTHC-insertion skills were assessed using a 28-item checklist. Methods: Participants underwent a pre-test of their NTHC-insertion skills at the internal jugular site using a realistic patient simulator and ultrasound machine. Participants then had a training session that included a didactic presentation and 2 hours of deliberate practice using the simulator. On the following day, trainees completed a post-test of their NTHC-insertion skills. All participants were required to meet or exceed a minimum passing score (MPS previously set at 79%. Trainees who did not reach the MPS were required to perform more deliberate practice until the MPS was achieved. Results: Twenty-two individuals participated in SBML training. None met or exceeded the MPS at baseline with a median checklist score of 20 (IQR, 7.25 to 21. Seventeen of 22 participants (77% completed post-testing and improved their scores to a median of 27 (IQR, 26 to 28; p < 0.001. All met or exceeded the MPS on their first attempt. There were no significant correlations between demographics

  9. Use of a national continuing medical education meeting to provide simulation-based training in temporary hemodialysis catheter insertion skills: a pre-test post-test study.

    Science.gov (United States)

    Clark, Edward G; Paparello, James J; Wayne, Diane B; Edwards, Cedric; Hoar, Stephanie; McQuillan, Rory; Schachter, Michael E; Barsuk, Jeffrey H

    2014-01-01

    Simulation-based-mastery-learning (SBML) is an effective method to train nephrology fellows to competently insert temporary, non-tunneled hemodialysis catheters (NTHCs). Previous studies of SBML for NTHC-insertion have been conducted at a local level. Determine if SBML for NTHC-insertion can be effective when provided at a national continuing medical education (CME) meeting. Describe the correlation of demographic factors, prior experience with NTHC-insertion and procedural self-confidence with simulated performance of the procedure. Pre-test - post-test study. 2014 Canadian Society of Nephrology annual meeting. Nephrology fellows, internal medicine residents and medical students. Participants were surveyed regarding demographics, prior NTHC-insertion experience, procedural self-confidence and attitudes regarding the training they received. NTHC-insertion skills were assessed using a 28-item checklist. Participants underwent a pre-test of their NTHC-insertion skills at the internal jugular site using a realistic patient simulator and ultrasound machine. Participants then had a training session that included a didactic presentation and 2 hours of deliberate practice using the simulator. On the following day, trainees completed a post-test of their NTHC-insertion skills. All participants were required to meet or exceed a minimum passing score (MPS) previously set at 79%. Trainees who did not reach the MPS were required to perform more deliberate practice until the MPS was achieved. Twenty-two individuals participated in SBML training. None met or exceeded the MPS at baseline with a median checklist score of 20 (IQR, 7.25 to 21). Seventeen of 22 participants (77%) completed post-testing and improved their scores to a median of 27 (IQR, 26 to 28; p < 0.001). All met or exceeded the MPS on their first attempt. There were no significant correlations between demographics, prior experience or procedural self-confidence with pre-test performance. Small sample-size and

  10. [Incidence of phlebitis due to peripherally inserted venous catheters: impact of a catheter management protocol].

    Science.gov (United States)

    Ferrete-Morales, C; Vázquez-Pérez, M A; Sánchez-Berna, M; Gilabert-Cerro, I; Corzo-Delgado, J E; Pineda-Vergara, J A; Vergara-López, S; Gómez-Mateos, J

    2010-01-01

    To assess the impact on the incidence of PPIVC by implementing a catheter management protocol and to determine risk factors for PPIVC development in hospitalized patients. A total of 3978 episodes of venous catheterization were prospectively included from September 2002 to December 2007. A catheter management protocol was implemented during this period of time. The incidence and variables associated to the occurrence of PPIVC were determined. The incidence of PPIVC from 2002 to 2007 was 4.8%, 4.3%, 3.6%, 2.5%, 1.3% and 1.8% (phistory of phlebitis was the only factor independently associated to phlebitis due to peripherally inserted central venous catheters (AOR 3.24; CI at 95% CI= 1.05-9.98, p=0.04). A catheter management protocol decreases the incidence of PPIVC in hospitalized patients. The risk of PPIVC increases for peripherally inserted central venous catheters when the patients have a history of phlebitis and for peripheral venous catheters when amiodarone or cefotaxime are infused. Catheterization of peripheral veins performed during morning shifts is associated with a lower incidence of PPIVC when compared with night shift catheterizations.

  11. NURSING CARE IN PATIENTS NEONATES WITH PERIPHERALLY INSERTED CENTRAL CATHETER

    Directory of Open Access Journals (Sweden)

    Anacilda Oliveira Vieira

    2013-12-01

    Full Text Available Introduction: The PICC (peripherally inserted central catheter is a long flexible catheter which is inserted through a peripheral vein, progresses through a needle introducer until the final portion of the vena cava, acquiring characteristics of a central catheter. Objective: To point out the main theoretical and scientific ideas that demonstrate the reliability, competence and ability of nurses to perform the PICC. Methodology: Systematic review of articles, which were found by searching the database scientific journals and bibliographies area. Results: The success of integration depends on the patient assessment and choice of venous access where the catheter will be positioned, and its tip should be in the middle third of the superior vena cava, or the middle third of the inferior vena cava. In neonates, which are used more frequently, proper positioning of the catheter is through nursing care in making the dressing, and the first 24 hours it should be compressive. Ideally, the PICC remains in the vein for periods longer than seven days or until the end of treatment, thus decreasing invasive procedures. Conclusion: According to the Federal Board of Nursing (COFEN, it is lawful for the insertion of PICC nurses, provided it has undergone professional training.

  12. Training of nurses on Foley catheter insertion in intensive care unit patients: limits and possibilities

    Directory of Open Access Journals (Sweden)

    Magno Conceição Merces

    2013-04-01

    Full Text Available Backgound and Objectives: Nursing has an important role in urinary tract infection prevention and control. Urinary catheters insertion represents the local topography with the highest rate of hospital infection. Foley catheter placement is performed solely by the nurse and requires aseptic techniques during its performance, thus preventing risks to the patients. The study aimed to evaluate the training of nurses on Foley catheter insertion and point out limits and possibilities of this practice in patients at the Intensive Care Unit (ICU of Hospital Geral do Interior da Bahia (HGIB. Methods: This was a qualitative, exploratory and descriptive study. Data collection was carried out through semi-structured interviews. After data analysis, two categories were evaluated, namely: the training of nurses on Foley catheter insertion in ICU patients and the limits and possibilities of Foley catheter insertion practice by nurses in ICU patients. Bardin analysis was used for data analysis. Results: The study shows that the nurse’s practice on Foley catheter insertion in ICU patients is based on the use of aseptic techniques for urinary tract infection prevention, theoretical and practical knowledge on Foley catheter insertion in ICU patients, knowledge on urinary tract infections and associations with catheter insertion, whereas the limits and possibilities of Foley catheter insertion practice by nurses are understood through measures to minimize the risk of hospital infection caused by long-term catheter use in the ICU. Nurses point out that the risks of hospital infection are inherent to long-term catheter use. This is an important fact, as the knowledge or its absence may constitute a limit or possibility for Foley catheter insertion practice by the nurse in ICU patients. Conclusion: Nurses must seek the systematization of knowledge, which warrants support for the team, as well as information, safety and prompt care, allowing the reduction of urinary

  13. Ultrasonic Guided Insertion of Central Venous Catheter in Infants ...

    African Journals Online (AJOL)

    Background/Purpose: ultrasound is licensed for application of regional blocks and insertion of vascular access. We aimed to compare ultrasonic guided (USG) and anatomical landmark technique (ALT) for insertion of central venous catheter (CVC) as regard success rate and rate of complications in infants and children.

  14. Migration of a Central Venous Catheter in a Hemodialysis Patient Resulted in Left Atrial Perforation and Thrombus Formation Requiring Open Heart Surgery.

    Science.gov (United States)

    Wong, Kevin; Marks, Barry A; Qureshi, Anwer; Stemm, Joseph J

    2016-07-01

    Central venous catheterization is widely used in patients on hemodialysis. A rare complication associated with the clinical use of central venous catheters is perforation of the heart or major vessels. We report a case of inadvertent perforation of the left atrium and thrombosis after the placement of a hemodialysis catheter in the right internal jugular vein. In such cases, surgical removal of the central venous catheter from perforation sites in the heart and vessel walls poses anesthetic challenges because of the high risk of pneumothorax, hemorrhage, arrhythmias, thrombosis, and death.

  15. Risk Factors Related to Peripherally Inserted Central Venous Catheter Nonselective Removal in Neonates

    Directory of Open Access Journals (Sweden)

    Xiaohe Yu

    2018-01-01

    Full Text Available We aimed to investigate the incidence and risk factors associated with nonselective removal of peripherally inserted central venous catheter (PICC in neonates. In this prospective cohort study, neonates who underwent PICC placement at neonatal intensive care units (NICUs in China from October 2012 to November 2015 were included. The patient demographics, catheter characteristics, catheter duration, PICC insertion site, indication for PICC insertion, infuscate composition, PICC tip location, and catheter complications were recorded in a computerized database. Risk factors for nonselective removal were analyzed. A total of 497 PICCs were placed in 496 neonates. Nonselective removal occurred in 9.3% of PICCs during 10,540 catheter-days (4.6 nonselective removals per 1,000 catheter-days. These included occlusion (3%, infection (1.4%, leakage (2.0%, phlebitis (0.6%, displacement (1%, pleural effusion(0.6%, and breaks (0.6%. Noncentral tip position was independently associated with an increased risk of nonselective removal (odds ratio 2.621; 95% confidence interval, 1.258-5.461 after adjusting for gestational age, sex, birth weight, and PICC dwell time. No significant differences in the rate of complications occurred between silastic and polyurethane PICC or different insertion sites. Noncentral PICC tip position was the only independent risk factor for nonselective removal of PICC.

  16. Blood flow measurements during hemodialysis vascular access interventions - Catheter-based thermodilution or Doppler ultrasound?

    DEFF Research Database (Denmark)

    Heerwagen, Søren T; Hansen, Marc A; Schroeder, Torben V

    2012-01-01

    by ultrasound dilution was determined within three days of the procedure. The methods were compared using regression analysis and tested for systematic bias. Results: Failure to position the thermodilutional catheter correctly was observed in 8 out of 46 (17%) pre-intervention measurements. Post-intervention......Purpose: To test the clinical performance of catheter-based thermodilution and Doppler ultrasound of the feeding brachial artery for blood flow measurements during hemodialysis vascular access interventions.Methods: Thirty patients with arteriovenous fistulas who underwent 46 interventions had...

  17. Direction of catheter insertion and the incidence of paresthesia during continuous epidural anesthesia in the elderly patients

    Science.gov (United States)

    Kim, Jong-Hak; Lee, Jun Seop

    2013-01-01

    Background Continuous epidural anesthesia is useful for endoscopic urologic surgery, as mostly performed in the elderly patients. In such a case, it is necessary to obtain successful sacral anesthesia, and the insertion of epidural catheter in the caudad direction may be needed. However, continuous epidural catherization has been related to paresthesias. This study aimed to evaluate the effects of the direction of the catheter insertion on the incidence of paresthesias in the elderly patients. Methods Two hundred elderly patients scheduled for endoscopic urologic surgery were enrolled. The epidural catheter was inserted at L2-3, L3-4, and L4-5 using the Tuohy needle. In Group I (n = 100), the Tuohy needle with the bevel directed the cephalad during the catheter insertion. In Group II (n = 100), it directed the caudad. During the catheter insertion, an anesthesiologist evaluated the presence of paresthesias and the ease or difficulty during the catheter insertion. Results In Group I (n = 97), 15.5% of the patients had paresthesias versus 18.4% in Group II (n = 98), and there was no significant difference between the two groups. In paresthesia depending on the insertion site and the ease or difficulty during the catheter insertion, there were no significant differences between the two groups. Conclusions Our results concluded that the direction of epidural catheter insertion did not significantly influence the incidence of paresthesias in the elderly patients. PMID:23741568

  18. Laparoscopic versus open peritoneal dialysis catheter insertion, the LOCI-trial: a study protocol

    Directory of Open Access Journals (Sweden)

    Hagen Sander M

    2011-12-01

    Full Text Available Abstract Background Peritoneal dialysis (PD is an effective treatment for end-stage renal disease. It allows patients more freedom to perform daily activities compared to haemodialysis. Key to successful PD is the presence of a well-functioning dialysis catheter. Several complications, such as in- and outflow obstruction, peritonitis, exit-site infections, leakage and migration, can lead to catheter removal and loss of peritoneal access. Currently, different surgical techniques are in practice for PD-catheter placement. The type of insertion technique used may greatly influence the occurrence of complications. In the literature, up to 35% catheter failure has been described when using the open technique and only 13% for the laparoscopic technique. However, a well-designed randomized controlled trial is lacking. Methods/Design The LOCI-trial is a multi-center randomized controlled, single-blind trial (pilot. The study compares the laparoscopic with the open technique for PD catheter insertion. The primary objective is to determine the optimum placement technique in order to minimize the incidence of catheter malfunction at 6 weeks postoperatively. Secondary objectives are to determine the best approach to optimize catheter function and to study the quality of life at 6 months postoperatively comparing the two operative techniques. Discussion This study will generate evidence on any benefits of laparoscopic versus open PD catheter insertion. Trial registration Dutch Trial Register NTR2878

  19. An intervention to improve the catheter associated urinary tract infection rate in a medical intensive care unit: Direct observation of catheter insertion procedure.

    Science.gov (United States)

    Galiczewski, Janet M; Shurpin, Kathleen M

    2017-06-01

    Healthcare associated infections from indwelling urinary catheters lead to increased patient morbidity and mortality. The purpose of this study was to determine if direct observation of the urinary catheter insertion procedure, as compared to the standard process, decreased catheter utilization and urinary tract infection rates. This case control study was conducted in a medical intensive care unit. During phase I, a retrospective data review was conducted on utilsiation and urinary catheter infection rates when practitioners followed the institution's standard insertion algorithm. During phase II, an intervention of direct observation was added to the standard insertion procedure. The results demonstrated no change in utilization rates, however, CAUTI rates decreased from 2.24 to 0 per 1000 catheter days. The findings from this study may promote changes in clinical practice guidelines leading to a reduction in urinary catheter utilization and infection rates and improved patient outcomes. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Technique to Avoid Hemodialysis Catheter in Patients with Failing Aneurysmal Arteriovenous Fistula by Creating a Concomitant New Arteriovenous Fistula.

    Science.gov (United States)

    Lara, Kelly A; Chua, Rochelle Anne; Vo, Trung D

    2018-05-01

    Autogenous arteriovenous fistula (AVF) is the primary recommended access for hemodialysis. Long-term use will not uncommonly result in AVF aneurysmal degeneration. Aneurysm-associated complications encompass pain, skin ulceration, infection, thrombosis, cannulation difficulties, and life-threatening bleeding. Various methods to repair aneurysmal AVFs have been described. However, there may be circumstances when this is not possible and require insertion of a temporary hemodialysis catheter (HDC) until a new arteriovenous access is created. We describe a case series of creating a new simultaneous AVF while continuing to use the primary failing aneurysmal AVF to avoid placement of an HDC. Once the new AVF becomes operational, the primary aneurysmal AVF can be abandoned. Six patients underwent simultaneous new AVF creation, 4 ipsilateral, and 2 contralateral. None of the patients developed symptomatic steal syndrome or congestive heart failure. Five of 6 patients had successful usage of the new AVF, and subsequently underwent ligation and excision of the aneurysmal AVF, thus avoiding a temporary HDC. Close monitoring for skin compromise and bleeding in the aneurysmal AVF is recommended while the new AVF matures. Copyright © 2018 Elsevier Inc. All rights reserved.

  1. Hemodialysis Access Usage Patterns in the Incident Dialysis Year and Associated Catheter-Related Complications

    Science.gov (United States)

    Xue, Hui; Ix, Joachim H.; Wang, Weiling; Brunelli, Steven M.; Lazarus, Michael; Hakim, Raymond; Lacson, Eduardo

    2012-01-01

    Background Hemodialysis(HD) access is considered a critical and actionable determinant of morbidity, with a growing literature suggesting that initial HD access type is an important marker of long term outcomes. Accordingly, we examined HD access during the incident dialysis period, focusing on infection risk and successful fistula creation over the first dialysis year. Study Design Longitudinal cohort Setting & Participants All United States adults admitted to Fresenius Medical Care North America facilities within 15 days of first maintenance dialysis session between January 1 and December 31, 2007. Predictor Vascular access type at HD initiation Outcomes Vascular access type at 90 days and at the end of the first year on HD, bloodstream infection within the first year by access type, and catheter complication rate. Results Amongst the 25,003 incident dialysis patients studied, 19,622(78.5%) initiated dialysis with a catheter, 4,151(16.6%) with a fistula, and 1,230(4.9%) with a graft. At 90 days, 14,105(69.7%) had a catheter, 4432(21.9%) patients had a fistula, and 1705(8.4%) had a graft. Functioning fistulas and grafts at dialysis initiation had first year failure rates of 10% and 15%, respectively. Grafts were seldom replaced by fistulas (3%), while 7,064 (47.6%) of all patients who initiated with a catheter alone still had only a catheter at 1 year. Overall, 3,327 (13.3%) patients had at least one positive blood culture during follow-up, with the risk being similar between fistula and graft groups, but approximately 3-fold higher in patients with a catheter (p<0.001 for either comparison). Nearly one in three catheters (32.5%) will require TPA use by median time of 41 days, with 59% requiring more than one TPA administration. Limitations Potential underestimation of bacteremia because follow-up blood culture results did not include samples sent to local laboratories. Conclusions Among a large and representative population of incident US dialysis patients

  2. Cost of installing and turning off hemodialysis on patients with central venous catheters

    Directory of Open Access Journals (Sweden)

    Gillene Santos Ferreira

    2014-12-01

    Full Text Available The objective was to identify the average total cost (ATC for installing and turning off hemodialysis on patients with central venous catheters. This quantitative, exploratory, and descriptive research, in the mode of a single-case study, was conducted in a public university hospital. The non-probabilistic sample corresponded to the observation of 100 installations and 100 terminations of hemodialysis on 42 patients during 23 days of collection. The ATC was calculated by multiplying the time spent by nurses by the unit cost of direct labor, and adding the cost of materials, solutions, and medications. The Brazilian currency (R$ was used for the calculations. The ATC for installation was R$ 80.10 and for shutting off was R$ 13.04, totaling R$ 93.14 per hemodialysis session. The results obtained will facilitate a better planning of the allocation of human, material, and financial resources enabling the increase of managerial strategies aimed at economic efficiency. doi: 10.5216/ree.v16i4.23044.

  3. The development of a risk score for unplanned removal of peripherally inserted central catheter in newborns

    Directory of Open Access Journals (Sweden)

    Priscila Costa

    2015-06-01

    Full Text Available OBJECTIVE: to develop a risk score for unplanned removal of peripherally inserted central catheter in newborns.METHOD: prospective cohort study conducted in a neonatal intensive care unit with newborn babies who underwent 524 catheter insertions. The clinical characteristics of the newborn, catheter insertion and intravenous therapy were tested as risk factors for the unplanned removal of catheters using bivariate analysis. The risk score was developed using logistic regression. Accuracy was internally validated based on the area under the Receiver Operating Characteristic curve.RESULTS: the risk score was made up of the following risk factors: transient metabolic disorders; previous insertion of catheter; use of a polyurethane double-lumen catheter; infusion of multiple intravenous solutions through a single-lumen catheter; and tip in a noncentral position. Newborns were classified into three categories of risk of unplanned removal: low (0 to 3 points, moderate (4 to 8 points, and high (≥ 9 points. Accuracy was 0.76.CONCLUSION: the adoption of evidence-based preventative strategies based on the classification and risk factors faced by the newborn is recommended to minimize the occurrence of unplanned removals.

  4. Clinical implications of acute pelvicaliceal hematoma formation during percutaneous catheter nephrostomy insertion.

    Science.gov (United States)

    Stewart, Jessica K; Smith, Tony P; Kim, Charles Y

    To determine the clinical implications of acute pelvicaliceal hematoma formation during percutaneous catheter nephrostomy (PCN) insertion. Collecting system hematoma burden was retrospectively assessed for 694 PCN insertions in 502 patients. Pelvicaliceal hematoma formation occurred in 146 kidneys (21%) in 136 patients. Clinically significant blood loss occurred in 3 patients with hematomas within one week compared to 4 patients without hematomas (p=0.39). Twenty-four patients with hematomas underwent catheter exchange within one week, compared to 55 patients without hematomas (p=0.49). Pelvicaliceal hematoma formation after PCN insertion is not uncommon and is associated with very rare clinical sequelae. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Surface-Treated versus Untreated Large-Bore Catheters as Vascular Access in Hemodialysis and Apheresis Treatments

    Directory of Open Access Journals (Sweden)

    Rolf Bambauer

    2012-01-01

    Full Text Available Background. Catheter-related infections, thrombosis, and stenosis are among the most frequent complications associated with catheters, which are inserted in vessels. Surface treatment processes of the outer surface, such as ion-beam-assisted deposition, can be used to mitigate such complications. Methods. This retrospective study (1992–2007 evaluated silver-coated (54 patients and noncoated (105 patients implanted large-bore catheters used for extracorporeal detoxification. The catheters were inserted into the internal jugular or subclavian veins. After removal, the catheters were cultured for bacterial colonization using standard microbiologic assays. They also were examined using scanning electron microscope. Results. The silver coated catheters showed a tendency towards longer in situ time. The microbiologic examinations of the catheter tips were in both catheter types high positive, but not significant. Conclusion. The silver-coated catheters showed no significantly reduction in infection rate by evaluation of all collected data in this retrospective study. There was no association between both catheters in significantly reducing savings in treatment costs and in reducing patient discomfort. Other new developed catheter materials such as the microdomain-structured inner and outer surface are considered more biocompatible because they mimic the structure of natural biological surface.

  6. Complications of Peripherally Inserted Central Venous Catheters: A Retrospective Cohort Study.

    Directory of Open Access Journals (Sweden)

    Paula Parás-Bravo

    Full Text Available The use of venous catheters is a widespread practice, especially in oncological and oncohematological units. The objective of this study was to evaluate the complications associated with peripherally inserted central catheters (PICCs in a cohort of patients.In this retrospective cohort study, we included all patient carrying PICCs (n = 603 inserted at our institute between October 2010 and December 2013. The main variables collected were medical diagnosis, catheter care, location, duration of catheterization, reasons for catheter removal, complications, and nursing care. Complications were classified as infection, thrombosis, phlebitis, migration, edema, and/or ecchymosis.All patients were treated according to the same "nursing care" protocol. The incidence rate of complications was two cases per 1000 days of catheter duration. The most relevant complications were infection and thrombosis, both with an incidence of 0.17 cases per 1000 days of the total catheterization period. The total average duration of catheterization was 170 days [SD 6.06]. Additionally to "end of treatment" (48.42% and "exitus", (22.53% the most frequent cause of removal was migration (displacement towards the exterior of the catheter (5.80%.PICCs are safe devices that allow the administration of long-term treatment and preserve the integrity of the venous system of the patient. Proper care of the catheter is very important to improve the quality life of patients with oncologic and hematologic conditions. Therefore, correct training of professionals and patients as well as following the latest scientific recommendations are particularly relevant.

  7. COST ANALYSIS OF PERIPHERALLY INSERTED CENTRAL CATHETER IN PEDIATRIC PATIENTS.

    Science.gov (United States)

    Dong, Zhaoxin; Connolly, Bairbre L; Ungar, Wendy J; Coyte, Peter C

    2018-01-01

    A peripherally inserted central catheter (PICC) is a useful option in providing secure venous access, which enables patients to be discharged earlier with the provision of home care. The objective was to identify the costs associated with having a PICC from a societal perspective, and to identify factors that are associated with total PICC costs. Data were obtained from a retrospective cohort of 469 hospitalized pediatric patients with PICCs inserted. Both direct and indirect costs were estimated from a societal perspective. Insertion costs, complication costs, nurse and physician assessment costs, inpatient ward costs, catheter removal costs, home care costs, travel costs, and the cost associated with productivity losses incurred by parents were included in this study. Based on catheter dwell time, the median total cost associated with a PICC per patient per day (including inpatient hospital costs) was $3,133.5 ($2,210.7-$9,627.0) in 2017 Canadian dollars ($1.00USD = $1.25CAD in 2017). The adjusted mean cost per patient per day was $2,648.2 ($2,402.4-$2,920.4). Excluding inpatient ward costs, the median total and adjusted costs per patient per day were $198.8 ($91.8-$2,475.8) and $362.7($341.0-$386.0), respectively. Younger age, occurrence of complications, more catheter dwell days, wards with more intensive care, and the absence of home care were significant factors associated with higher total PICC costs. This study has demonstrated the costs associated with PICCs. This information may be helpful for healthcare providers to understand PICC related cost in children and resource implications.

  8. Tinzaparin is safe and effective in the management of hemodialysis catheter thrombosis.

    LENUS (Irish Health Repository)

    Quinlan, Catherine

    2012-08-27

    Children on hemodialysis are at increased risk of thrombosis, especially when dialyzed via a central venous catheter (CVC); there are limited published data regarding the safety and efficacy of tinzaparin in this group. We conducted a retrospective chart review of all children in the National Pediatric Hemodialysis Centre for Ireland diagnosed with a CVC thrombus and treated with subcutaneous tinzaparin over a 10 year period. Seven children were treated with subcutaneous tinzaparin for 10 CVC thrombi. Tinzaparin was commenced at 175 IU\\/kg\\/day and the dose was titrated by measuring anti-factor Xa levels, aiming for levels of 0.3-1.0 IU\\/ml. Treatment was continued until resolution of the CVC thrombus. Restoration of normal flows during dialysis occurred within 3 days in all patients. There were no episodes of bleeding and all children tolerated the treatment well.

  9. A Retrospective Quality Study of Hemodialysis Catheter-Related Bacteremia in a Danish Hospital

    DEFF Research Database (Denmark)

    Kaarup, Sophie; Olesen, Bente; Pourarsalan, Mahshid

    2016-01-01

    and surveillance is a critical aspect of infection control and prevention. Aim: To analyze incidence, causative species, and treatment of HD CRB in adult chronic HD patients at Nordsjaellands Hospital (NOH), Denmark. Methods: All episodes of bacteremia in the Department of Cardiology, Nephrology and Endocrinology......%), enterobacteriaceae (20%) and enterococci (8%). The most commonly used empiric antimicrobials were cefuroxime and vancomycin and the overall efficacy was 77%. Conclusion: The well-functioning infection prevention strategy seems to be successful resulting in a relatively low incidence rate of HD CRB compared......Background: Hemodialysis catheter-related bacteremia (HD CRB) is a major complication of long-term hemodialysis (HD) therapy and bacteremia is secondary only to cardiovascular disease as the leading cause of death in patients receiving renal replacement therapy. A large part may be preventable...

  10. SURVIVAL OF CONTINUOUS AMBULATORY PERITONEAL DIALYSIS CATHETERS: AN EVALUATION OF SURGICAL AND NON-SURGICAL FACTORS (SINGLE CENTER STUDY

    Directory of Open Access Journals (Sweden)

    A. Keshvari

    2006-06-01

    Full Text Available Peritoneal dialysis is an established form of renal replacement therapy used in many patients with end-stage renal disease. The key to a successful chronic peritoneal dialysis is a permanent and safe access to the peritoneal cavity. This study was conducted in order to evaluate the catheter survival and its related factors in Imam Khomeini Hospital. A total of 80 catheters were inserted into 69 patients (52 men and 28 women with end-stage chronic renal failure during a period of 84 months. Retrospectively the correlation between catheter survival (overall and event free with demographic factors (sex and age, surgical factors (surgeons and surgical methods, nephrologic factors (the causes of peritoneal dialysis selection and the history of hemodialysis and peritonitis factors (the history and number of peritonitis has been evaluated. The mean age of the patients was 48.35 years (16 to 79 years. The overall survival of catheters or the probability of having a functioning catheter after one, two and three years was 53%, 41%, 22%, respectively. The event free survival of the catheter or the probability of having a functioning catheter without any problems after one year was 14%. It has been found out that among all factors in this study only history of hemodialysis had statistically significant effect on the overall survival of continuous ambulatory peritoneal dialysis catheter (P = 0.04. It seems that the overall survival of catheters is better when CAPD is started before any other attempts for hemodialysis.

  11. The effects of lavender aromatherapy on pain following needle insertion into a fistula in hemodialysis patients.

    Science.gov (United States)

    Bagheri-Nesami, Masoumeh; Espahbodi, Fatemeh; Nikkhah, Attieh; Shorofi, Seyed Afshin; Charati, Jamshid Yazdani

    2014-02-01

    This study sought to determine the effects of lavender aromatherapy on pain following needle insertion into a fistula in patients undergoing hemodialysis. This is a randomized controlled clinical trial in which 92 patients undergoing hemodialysis with arteriovenous fistulas were randomly divided into two groups. The experimental-group patients inhaled lavender essence with a concentration of 10% for 5 min during 3 hemodialysis sessions, while the control-group patients received aromatherapy free of lavender essence. The mean VAS pain intensity score in the experimental and control groups before the intervention was 3.78 ± 0.24 and 4.16 ± 0.32, respectively (p = 0.35). The mean VAS pain intensity score in the experimental and control groups after three aromatherapy sessions was 2.36 ± 0.25 and 3.43 ± 0.31, respectively (p = 0.009). Lavender aromatherapy may be an effective technique to reduce pain following needle insertion into a fistula in hemodialysis patients. Copyright © 2013 Elsevier Ltd. All rights reserved.

  12. Central venous obstruction in hemodialysis patients: the usefulness of percutaneous treatment

    International Nuclear Information System (INIS)

    Kim, Cheol Young; Goo, Dong Erk; Kim, Dae Ho; Hong, Hyun Suk; Lee, Hae Kyoung; Choi, Duk Lin; Yang, Sung Boo; Moon, Chul

    2002-01-01

    To analyse the effectiveness of percutaneous treatment of central venous obstruction in patients undergoing hemodialysis. In 100 patients, 107 central venous strictures (56 subclavian (occlusion:21, stenosis:35) and 51 innominate (occlusion:23,stenosis:28)) were assessed, and 170 percutaneous angioplasty procedures were performed. Balloon dilation of the venous lumen was the preferred mode, but if dilation was incomplete we inserted a stent at the site of the stricture. Technical success, procedural complications and the long-term patency rate were evaluated, and the patency difference according to location and degree of stricture, the existence of DM, and any history of central catheter insertion was also determined. We inserted 52 stents in 170 procedures, in 157 (92.4%) of which initial technical success was achieved. Stent migration occurred in two cases and balloon rupture in three. The 6- and 12-month primary patency rates were 46.2% and 24.1%, respectively, and the mean patency rate was 8.5 months. The 1-, 2-and 3-year accumulative patency rates were 59.8%, 47.5% and 35.7%, respectively, and the mean patency rate was 23.5 months. Other than in the history of central catheter insertion, there were no statistically significant differences in patency rates (p=0.0128). In hemodialysis patients with a central venous stricture, percutaneous angioplasty is a safe and useful procedure, but to maintain long-term central venous patency, repeated interventions are required

  13. Infectious Complications of Radiologically Inserted Hickman Catheters in Patients with Hematologic Disorders

    International Nuclear Information System (INIS)

    Bakker, Jeannette; Overhagen, Hans van; Wielenga, Jenne; Marie, Siem de; Nouwen, Jan; Ridder, Marie A.J. de; Lameris, Johan S.

    1998-01-01

    Purpose: To assess the incidence of infections and its influence on the survival of radiologically inserted Hickman catheters (HCs) in patients with hematologic disorders and to determine factors associated with premature HC removal. Methods: Survival and complications of 175 HCs in 115 patients were studied retrospectively. To describe the data the Kaplan-Meier method and the log-rank test were used, using the date of HC removal due to HC-related infection as endpoint. A stratified Cox regression model was used to determine explanatory factors. Results: Seventy (40%) HCs were removed prematurely because of proven or probable HC-related infections. The incidence of infection leading to HC removal was 4.78 per 1000 catheter-days for proven HC infections. Univariate analysis revealed that acute myeloid leukemia, acute lymphocytic leukemia, or treatment for these diseases, gender, each subsequent catheter in the same patient and insertion site increased the risk of premature removal of the catheter due to infection. Conclusion: Infection is a major problem in patients with HCs. Unfortunately, the factors associated with increased infection rates that were found in this study cannot be influenced. Further studies are necessary to determine the role of environmental conditions in a radiology suite in relation to the risk of developing a catheter-related infection

  14. Peripherally inserted central catheters in infants and children - indications, techniques, complications and clinical recommendations

    DEFF Research Database (Denmark)

    Westergaard, B; Classen, V; Walther-Larsen, S

    2013-01-01

    of perioperative complications. Assisted visualisation, preferably with ultrasound, yields high rates of insertion success. With good catheter care, rates of mechanical, infectious and thrombotic complications are low and compare favourably with those of traditional central venous catheters. Even in the case...... of occlusion or infection, fibrinolytics and antibiotic locks often allow the catheter to be retained....

  15. Hemodialysis catheter insertion: is increased PO2 a sign of arterial cannulation? A case report.

    Science.gov (United States)

    Chirinos, Julio C; Neyra, Javier A; Patel, Jiten; Rodan, Aylin R

    2014-07-29

    Ultrasound-guided Central Venous Catheterization (CVC) for temporary vascular access, preferably using the right internal jugular vein, is widely accepted by nephrologists. However CVC is associated with numerous potential complications, including death. We describe the finding of a rare left-sided partial anomalous pulmonary vein connection during central venous catheterization for continuous renal replacement therapy (CRRT). Ultrasound-guided cannulation of a large bore temporary dual-lumen Quinton-Mahurkar catheter into the left internal jugular vein was performed for CRRT initiation in a 66 year old African-American with sepsis-related oliguric acute kidney injury. The post-procedure chest X-ray suggested inadvertent left carotid artery cannulation. Blood gases obtained from the catheter showed high partial pressure of oxygen (PO2) of 140 mmHg and low partial pressure of carbon dioxide (PCO2) of 22 mmHg, suggestive of arterial cannulation. However, the pressure-transduced wave forms appeared venous and Computed Tomography Angiography located the catheter in the left internal jugular vein, but demonstrated that the tip of the catheter was lying over a left pulmonary vein which was abnormally draining into the left brachiocephalic (innominate) vein rather than into the left atrium. Although several mechanical complications of dialysis catheters have been described, ours is one of the few cases of malposition into an anomalous pulmonary vein, and highlights a sequential approach to properly identify the catheter location in this uncommon clinical scenario.

  16. [The ISP (Safe Insertion of PICCs) protocol: a bundle of 8 recommendations to minimize the complications related to the peripherally inserted central venous catheters (PICC)].

    Science.gov (United States)

    Emoli, Alessandro; Cappuccio, Serena; Marche, Bruno; Musarò, Andrea; Scoppettuolo, Giancarlo; Pittiruti, Mauro

    2014-01-01

    The ISP (Safe Insertion of PICCs) protocol: a bundle of 8 recommendations to minimize the complications related to the peripherally inserted central venous catheters (PICC). The insertion of a peripherally inserted central venous catheter (PICC) is not without risks. The Italian Group for the Study of Long-Term Central Venous Access Devices (GAVeCeLT) has developed a protocol (SIP: Safe Implantation of PICCs) with the aim of minimizing the risks which may be associated with the placement of PICCs. The protocol is based on recommendations available in the literature and on the main clinical practice guidelines. The SIP protocol, a bundle of evidence-based recommendations, it is is easy to use, inexpensive, and cost-effective. If routinely used and carefully inplemented, it greatly reduces complications such as failure of venipuncture, accidental arterial puncture, damage of median nerve, infection and catheter related venous thrombosis.

  17. The effect of peripherally inserted central catheter (PICC) valve technology on catheter occlusion rates--the 'ELeCTRiC' study.

    Science.gov (United States)

    Johnston, Andrew J; Streater, Carmel T; Noorani, Remy; Crofts, Joanne L; Del Mundo, Aldwin B; Parker, Richard A

    2012-01-01

    Peripherally Inserted Central Catheters (PICCs) are increasingly being used to provide short to medium-term central venous access. The current study was designed to test the hypothesis that PICC valve technology does not influence PICC occlusion rates. Intensive care unit (ICU) patients who required a PICC were randomized to one of three types of dual lumen PICC (open ended non-valved, Groshong valve, PASV valve). PICC occlusions were recorded and managed with a protocol that used urokinase. A total of 102 patients were recruited to the study. The overall risk of occlusion per catheter was 35% (95% CI 26% to 44%). The overall rate of occlusion was 76 occlusions per 1000 catheter days (95% CI 61 to 95). Presence or type of valve did not significantly influence this rate (open-ended non-valved PICC 38% of catheters, 79 occlusions per 1000 catheter days; Groshong 38% of catheters, 60 occlusions per 1000 catheter days; PASV 27% of catheters, 99 occlusions per 1000 catheter days). The dose of urokinase required to treat PICC occlusions did not significantly differ between PICC types. Valved PICCs do not appear to influence PICC occlusion rates.

  18. Does Guidewire Exchange Influence Infection Rate Related to Catheters Used for Vascular Access in Children on Chronic Hemodialysis?

    Science.gov (United States)

    Rus, Rina R; Battelino, Nina; Ponikvar, Rafael; Premru, Vladimir; Novljan, Gregor

    2017-02-01

    A central venous catheter (CVC) can either be inserted "de novo" or placed by guidewire exchange (GWE). From September 1998 to September 2015, 32 children (19 boys, 13 girls) were hemodialyzed in our unit by using a CVC. The mean age at CVC insertion was 12.6 ± 0.5 years. A total of 121 uncuffed catheters were placed, either "de novo" or by GWE in 64 (52.9%) and 57 (47.1%) cases, respectively. The most frequent cause for line revision was catheter dysfunction in 40/121 (33.1%) patients. The overall incidence of bacteremia was 1.5/1000 catheter-days. The incidence in newly inserted and GWE catheters was 1.4 and 1.7/1000 catheter-days, respectively. The difference did not reach statistical significance (P = 0.939). The infection rate correlated with patient age, and was higher in younger children (P = 0.006). GWE is an effective option of line revision, and did not influence the infection rate in our study. © 2016 International Society for Apheresis, Japanese Society for Apheresis, and Japanese Society for Dialysis Therapy.

  19. Surgical insertion of central venous catheters in low-birth-weight ...

    African Journals Online (AJOL)

    Aim: Neonatal central vascular access (CVA) represents a daily practice in neonatal intensive care unit. Low birth weight (LBW) neonates pose a challenge to anesthetists who try the landmark technique to cannulate central veins. We reported our experience of open surgical cutdown (OSC) to insert catheters through right ...

  20. Improving patient safety during insertion of peripheral venous catheters: an observational intervention study

    Directory of Open Access Journals (Sweden)

    Kampf, Günter

    2013-11-01

    Full Text Available [english] Background: Peripheral venous catheters are frequently used in hospitalized patients but increase the risk of nosocomial bloodstream infection. Evidence-based guidelines describe specific steps that are known to reduce infection risk. However, the degree of guideline implementation in clinical practice is not known. The aim of this study was to determine the use of specific steps for insertion of peripheral venous catheters in clinical practice and to implement a multimodal intervention aimed at improving both compliance and the optimum order of the steps.Methods: The study was conducted at University Hospital Hamburg. An optimum procedure for inserting a peripheral venous catheter was defined based on three evidence-based guidelines (WHO, CDC, RKI including five steps with 1A or 1B level of evidence: hand disinfection before patient contact, skin antisepsis of the puncture site, no palpation of treated puncture site, hand disinfection before aseptic procedure, and sterile dressing on the puncture site. A research nurse observed and recorded procedures for peripheral venous catheter insertion for healthcare workers in four different departments (endoscopy, central emergency admissions, pediatrics, and dermatology. A multimodal intervention with 5 elements was established (teaching session, dummy training, e-learning tool, tablet and poster, and direct feedback, followed by a second observation period. During the last observation week, participants evaluated the intervention.Results: In the control period, 207 insertions were observed, and 202 in the intervention period. Compliance improved significantly for four of five steps (e.g., from 11.6% to 57.9% for hand disinfection before patient contact; p<0.001, chi-square test. Compliance with skin antisepsis of the puncture site was high before and after intervention (99.5% before and 99.0% after. Performance of specific steps in the correct order also improved (e.g., from 7.7% to 68

  1. Percutaneous insertion of peritoneal dialysis catheters using ultrasound and fluoroscopic guidance: A single centre experience and review of literature

    International Nuclear Information System (INIS)

    De Boo, Diederick W.; Mott, Nigel; Tregaskis, Peter; Quach, Trung; Menahem, Solomon; Walker, Rowan G.; Koukounaras, Jim

    2015-01-01

    Various methods of peritoneal dialysis (PD) catheter insertion are available. The purpose of this study was to evaluate a percutaneous insertion technique using ultrasound (US) and fluoroscopy performed under conscious sedation and as day case procedure. Data of 87 percutaneous inserted dialysis catheters were prospectively collected, including patients' age, gender, body mass index, history of previous abdominal surgery and cause of end stage renal failure. Length of hospital stay, early complications and time to first use were also recorded. Institutional review board approval was obtained. A 100% technical success rate was observed. Early complications included bleeding (n = 3), catheter dysfunction (n = 6), exit site infection (n = 1) and exit site leakage (n = 1). All cases of catheter dysfunction and one case of bleeding required surgical revision. Median time of follow-up was 18 months (range 3–35), and median time from insertion to first use was days 14 (1–47). Of the 82 patients who started dialysis, 20 (23%) ceased PD at some stage during follow-up. Most frequently encountered reasons include deteriorating patient cognitive or functional status (n = 5), successful transplant kidney (n = 4) and pleuro-peritoneal fistula (n = 4). Sixty-two (71%) PD catheter insertions were performed as day case. The remaining insertions were performed on patients already admitted to the hospital. Percutaneous insertion of dialysis catheter using US and fluoroscopy is not only safe but can be performed as day case procedure in most patients, even with a medical history of abdominal surgery and/or obesity.

  2. A nurse led peripherally inserted central catheter line insertion service is effective with radiological support

    International Nuclear Information System (INIS)

    Barber, Jonathan M.; Booth, Doris M.; King, Julia A.; Chakraverty, Sam

    2002-01-01

    AIM: Peripherally inserted central catheters (PICC) are increasingly used as a route of chemotherapy administration. Our aims were to assess a collaborative approach to PICC placement, with radiological support for a nurse led line insertion service in a minority of cases, and to determine whether PICC provided a safe and reliable method of chemotherapy administration. MATERIALS AND METHODS: Prospective data on 100 consecutive patients undergoing PICC placement for chemotherapy were collected. Lines were inserted by ward based nurses or under ultrasound guidance by radiologists. End points were successful completion of treatment or patient death. RESULTS: One hundred and forty-four lines were placed for 118 courses of chemotherapy. 107 (74%) were placed by nurses and 37 (26%) by radiologists. Ninety-five percent of patients completed therapy with either one or two lines. Seventy percent of lines were removed on achieving the primary end points. In two additional patients PICC could not be placed radiologically. Twelve patients were unable to complete treatment with PICC alone, nine of these required an alternative administration route. The catheter related sepsis rate was 4.9%. CONCLUSION: The majority of PICC can be successfully placed by trained nurses, reserving image guidance only for more difficult cases. PICC have an acceptable complication profile, and decrease the need for tunnelled central lines. Barber, J.M. et al. (2002)

  3. Comparative study of peripherally inserted central venous catheter and traditional central catheter assisted with X-ray

    International Nuclear Information System (INIS)

    Yu Jianchun; Wang Xiurong; Jiang Zhuming

    1999-01-01

    Objective: To study the feasibility, complications, mid- and long-term advantages of peripherally inserted central catheters (PICC) compared with central venous access assisted with X-ray. Methods: From Jan 1997 to Dec 1998, the authors conducted a study in 60 patients with placed PICC lines and 60 patients with central lines. Study variables included tip placement and complication rates. Results: Tere were on significant differences between PICC and CVC in the successful placement 95.0% and 88.3%, t = 1.745, P 0.19; the mean duration 13(6-98) days and 14 (7-104) days, F = 0.049, P = 0.83; the total occlusion rate 6.7% (4/60) and 5.0%(3/60), t = 0.152, P = 0.70. In PICC patients, the occlusion rate was slightly higher in 3 Fr (20-gauge) catheter (3/20, 15.0%) than in 4 Fr(18-gauge) catheters (1/20, 5.0%), t = 1.111, P=0.29. Phlebitis occurred in 5.0% of patients (3/60) and one catheter fracture was happened on the catheter hub junction (1.7%). In 3 catheter tips dislocation cases, the catheter tips were moved to the optional position assisted with X-ray image. In CVC group, pneumothorax happened in 1 case (1.7%). In 4 catheter dislocation cases, the catheters were with drawn. No catheter-related sepsis and hemo-pneumothorax happened in both group patients. Conclusions: Both PICC and CVC can be acceptable in clinical use. PICC assisted with X-ray possesses the advantages of less trauma, accurate localization preventing some possible severe complications of central venous access such as pneumothorax. The new method provides a reliable, effective venous access for mid-and long-term usage in patients receiving a variety of solutions, primarily parenteral alimentation, chemotherapy or antibiotic infusion

  4. Can femoral dialysis catheter insertion cause a life threatening complication?

    Directory of Open Access Journals (Sweden)

    Nurkay Katrancıoğlu

    2014-09-01

    Full Text Available Venous catheter (VC insertion may be necessary for the patients with renal failure facing vascular access problem. Femoral VCs are commonly used for their lower complication rates especially in emergency clinics. The incidence of bleeding associated with VC is reported 0.5-1.6%, however, life threatening hemorrhage and complications requiring surgical intervention are very rare. In this manuscript, we aimed to present a case with hemolytic uremic syndrome complicated with retroperitoneal hematoma after femoral VC insertion. J Clin Exp Invest 2014; 5 (3: 472-474

  5. Feasibility of Endovascular Radiation Therapy Using Holmium-166 Filled Balloon Catheter in a Swine Hemodialysis Fistula Model: Preliminary Results

    Energy Technology Data Exchange (ETDEWEB)

    Won, Jong Yun; Lee, Kwang Hun; Lee, Do Yun [Dept. of Radiology, Research Institute of Radiological Science, Yensei University College of Medicine, Seoul (Korea, Republic of); Kim, Myoung Soo [Dept. of Radiology, Yensei University College of Medicine, Seoul (Korea, Republic of); Kang, Byung Chul [Dept. of Radiology, Internal Medicine, EwhaWoman' s University School of Medicine, Seoul (Korea, Republic of); Kim, Seung Jung [Dept. of Internal Medicine, EwhaWoman' s University School of Medicine, Seoul (Korea, Republic of)

    2011-08-15

    To describe how to make a swine hemodialysis fistula model and report our initial experience to test the feasibility of endovascular radiation therapy with Holmium-166 filled balloon catheters. The surgical formation of arterio-venous fistula (AVF) was performed by end-to-side anastomosis of the bilateral jugular vein and carotid artery of 6 pigs. After 4 weeks, angiograms were taken and endovascular radiation was delivered to the venous side of AVF with Holmium-166 filled balloon catheters. Pigs were sacrificed 4 weeks after the radiation and AVFs were harvested for histological examination. All animals survived without any morbidity during the experimental periods. The formation of fistula on the sides of necks was successful in 11 of the 12 pigs (92%). One AVF failed from the small jugular vein. On angiograms, 4 of the 11 AVFs showed total occlusion or significant stenosis and therefore, endovascular radiation could not be performed. Of 7 eligible AVFs, five underwent successful endovascular radiation and two AVFs did not undergo radiation for the control. Upon histologic analysis, one non-radiated AVF showed total occlusion and others showed intimal thickening from the neointimal hyperplasia. Formation of the swine carotid artery-jugular vein hemodialysis fistula model was successful. Endovascular radiation using a Holmium-166 filled balloon catheter was safe and feasible.

  6. Incidence of upper limb venous thrombosis associated with peripherally inserted central catheters (PICC).

    Science.gov (United States)

    Abdullah, B J J; Mohammad, N; Sangkar, J V; Abd Aziz, Y F; Gan, G G; Goh, K Y; Benedict, I

    2005-07-01

    The objective of this study was to prospectively determine the incidence of venous thrombosis (VT) in the upper limbs in patients with peripherally inserted central catheters (PICC). We prospectively investigated the incidence of VT in the upper limbs of 26 patients who had PICC inserted. The inclusion criteria were all patients who had a PICC inserted, whilst the exclusion criterion was the inability to perform a venogram (allergies, previous contrast medium reaction and inability of gaining venous access). Both valved and non-valved catheters were evaluated. Prior to removal of the PICC, an upper limb venogram was performed. The number of segments involved with VT were determined. The duration of central venous catheterization was classified as; less than 6 days, between 6 days and 14 days and more than 14 days. VT was confirmed in 38.5% (10/26) of the patients. The majority 85.7% (12/14) were complete occlusive thrombi and the majority of VT only involved one segment. There was no statistical correlation between the site of insertion of the PICC and the location of VT. Neither was there any observed correlation between the occurrence of VT with the patient's history of hypertension, hypercholesterolaemia, coronary artery disease, diabetes mellitus, cardiac insufficiency, smoking or cancer. There was also no statistical correlation with the size of the catheter. In conclusion, PICCs are associated with a significant risk of upper extremity deep vein thrombosis (UEVT).

  7. Hemodialysis Catheters: How to Keep Yours Working Well

    Science.gov (United States)

    ... for specific treatment recommendations. Print Email Read related articles Home Hemodialysis Nocturnal Hemodialysis What Is Dry Weight Nutrition and Hemodialysis The Buttonhole Technique The National Kidney ...

  8. [Peripherally inserted central catheter antibiotic therapy for cystic fibrosis patients].

    Science.gov (United States)

    Betegnie, A-L; Cracowski, C; Bedouch, P; Segond, C; Robein-Dobremez, M-J; Pin, I; Allenet, B

    2014-11-01

    Peripherally inserted central catheters (PICC) are more and more used for intravenous antibiotic infusions in cystic fibrosis (CF) patients in the Grenoble area (France). The aim of this study was to assess the use of this technique in this indication. 1. Retrospective evaluation of 102 consecutive PICC insertions over 3years and the incidence of adverse events during the therapy. 2. Prospective evaluation of 12 patient's satisfaction and their nurses over a 3-month period. 3. Comparative analysis of single domiciliary treatment costs using PICC versus peripheral catheter (PC). 102 PICC insertions were attempted in 31 patients. Seven failures and 7 complications occurred during the treatment requiring removal of the PICC, i.e. an overall success rate of 86.2% (88/102). Pain during PICC introduction was 4.2/10 (visual analogical scale). Mean satisfaction levels during therapy were 9.3/10 for patients and 8.7/10 for nurses. Compared with PC, all the patients said that PICC was "more comfortable". Differential costs of treatment with PC and with PICC at home were estimated at 57.15€ and 590.16€ respectively. PICC is an alternative to CP for intravenous antibiotherapy in CF patients, providing better safety and comfort. PICC use should be promoted in this indication. Copyright © 2013 SPLF. Published by Elsevier Masson SAS. All rights reserved.

  9. Incidence of thrombosis in children with tunneled central venous access devices versus peripherally inserted central catheters (PICCs).

    Science.gov (United States)

    Kanin, Maralee; Young, Guy

    2013-11-01

    The recent proliferation of deep vein thrombosis in children has been attributed to the increased use of central venous catheters, specifically tunneled lines and peripherally inserted central catheters. A formal comparison of the incidence rate for deep vein thrombosis between tunneled lines and peripherally inserted central catheters has not been undertaken. Children inclusion. Data were extracted from the hospital discharge database which includes data on all procedures and up to 20 diagnoses per admission. Diagnoses and procedures were identified by International Classification of Disease, Ninth Revision coding. Patients were excluded if they received more than one central line. Data collected included type of central line, deep vein thrombosis event, and underlying medical illnesses classified according to chronic complex conditions. Over the seven year study period there was an overall rate of 73 deep vein thromboses per 10,000 hospital discharges. Of the 6915 eligible subjects, 181 had a deep vein thrombosis for an overall incidence rate of 2.6%. There were 152 thrombi (2.6%) in subjects with peripherally inserted central catheters and 29 thrombi (3.1%) in subjects with tunneled lines [OR=.83 (0.55, 1.29), p=0.38]. Despite the relative ease and simplicity of use of peripherally inserted central catheters leading to a substantial rise in their use, this study demonstrates that such lines pose a substantial risk for venous thrombosis and no difference in incidence was detected between such lines and tunneled lines. © 2013.

  10. REcanalisation and Balloon-Oriented Puncture for Re-Insertion of Dialysis Catheter in Nonpatent Central Veins (REBORN)

    International Nuclear Information System (INIS)

    Too, Chow Wei; Sayani, Raza; Lim, Elvin Yuan Ting; Leong, Sum; Gogna, Apoorva; Teo, Terence K.

    2016-01-01

    PurposeTo describe a technique involving REcanalisation and Balloon-Oriented puncture for Re-insertion of dialysis catheter in Nonpatent central veins (REBORN) and to report long-term results.Materials and MethodsThis is a retrospective study of ten subjects in whom dialysis catheters were inserted using the REBORN technique from March 2012 to October 2014 and followed up till April 2016. Data on the duration of catheter usage, complications and reasons for removal were obtained. Seven patients had partially occluded lower internal jugular veins (IJV) recanalised in an antegrade fashion via a more cranial puncture. The balloon was then inflated at usual puncture site with an 18G needle. The collapsed balloon was cannulated with a guide wire, and both balloon and guide wire were advanced together into the superior vena cava. This was followed by tunnelled catheter placement using standard techniques. Two patients had catheters placed in the subclavian vein using a similar antegrade technique, and one patient had catheter placed via the left IJV following retrograde recanalisation from a right femoral puncture.ResultsMean duration of catheter use was 278 days (range 32–503). Three catheters were removed due to matured arteriovenous accesses. Four patients had successful catheter change over the same subcutaneous track due to catheter malfunction. One catheter was removed after 7 months because of sepsis. No complications were reported.ConclusionThe REBORN technique allows for the preservation of central veins for future haemodialysis access, which can be challenging in patients requiring long-term dialysis.

  11. REcanalisation and Balloon-Oriented Puncture for Re-Insertion of Dialysis Catheter in Nonpatent Central Veins (REBORN)

    Energy Technology Data Exchange (ETDEWEB)

    Too, Chow Wei, E-mail: toochowwei@gmail.com [Singapore General Hospital (Singapore); Sayani, Raza [Aga Khan University Hospital (Pakistan); Lim, Elvin Yuan Ting; Leong, Sum; Gogna, Apoorva [Singapore General Hospital (Singapore); Teo, Terence K. [Mount Elizabeth Novena Hospital (Singapore)

    2016-08-15

    PurposeTo describe a technique involving REcanalisation and Balloon-Oriented puncture for Re-insertion of dialysis catheter in Nonpatent central veins (REBORN) and to report long-term results.Materials and MethodsThis is a retrospective study of ten subjects in whom dialysis catheters were inserted using the REBORN technique from March 2012 to October 2014 and followed up till April 2016. Data on the duration of catheter usage, complications and reasons for removal were obtained. Seven patients had partially occluded lower internal jugular veins (IJV) recanalised in an antegrade fashion via a more cranial puncture. The balloon was then inflated at usual puncture site with an 18G needle. The collapsed balloon was cannulated with a guide wire, and both balloon and guide wire were advanced together into the superior vena cava. This was followed by tunnelled catheter placement using standard techniques. Two patients had catheters placed in the subclavian vein using a similar antegrade technique, and one patient had catheter placed via the left IJV following retrograde recanalisation from a right femoral puncture.ResultsMean duration of catheter use was 278 days (range 32–503). Three catheters were removed due to matured arteriovenous accesses. Four patients had successful catheter change over the same subcutaneous track due to catheter malfunction. One catheter was removed after 7 months because of sepsis. No complications were reported.ConclusionThe REBORN technique allows for the preservation of central veins for future haemodialysis access, which can be challenging in patients requiring long-term dialysis.

  12. Placement of a peripherally inserted central catheter into the azygous vein

    Energy Technology Data Exchange (ETDEWEB)

    Franklin, Iain, E-mail: iain.franklin@health.qld.gov.au; Gilmore, Christopher [The Prince Charles Hospital, Brisbane, Queensland (Australia)

    2015-06-15

    Peripherally inserted central catheters (PICC) are used for a variety of infusion therapies. They are indicated in patients requiring long-term venous access. Incorrect positioning of the insertion of a PICC line is one of the known complications when inserting the device in clinical practice. Radiographers once performing imaging will commonly check if the tip of a PICC has entered the superior vena cava. This case study will report on a lesser known incorrect placement of a PICC line into the azygous vein and how this can be detected on radiographic imaging. This outcome for the patient can be detrimental as it has an increased risk of perforation, thrombus, and fistula formation.

  13. Efficacy of two antiseptic regimens on skin colonization of insertion sites for two different catheter types: a randomized, clinical trial.

    Science.gov (United States)

    Lutz, Juergen Thomas; Diener, Isabel Victoria; Freiberg, Kerstin; Zillmann, Robert; Shah-Hosseini, Kija; Seifert, Harald; Berger-Schreck, Bettina; Wisplinghoff, Hilmar

    2016-12-01

    Catheter-related bloodstream infections affect patients in surgical and intensive care settings worldwide, causing complications, aggravation of existing symptoms and increased length of stay. The trial aimed at comparing two registered skin antiseptics with respect to their residual and therefore infection-preventing effects. In a parallel, monocentric, prospective, triple-blind, randomized trial the difference in bacterial recolonization of catheter skin sites in central venous (CVC) and epidural catheters (EC) was investigated by comparing two alcoholic-based skin disinfectants. Patients receiving planned surgeries or intensive care were eligible for the trial. Those in the trial group received skin disinfection with the additive octenidine dihydrochloride (OCT) (n = 51), those in the control group were treated with benzalkonium chloride as additive (BAC) (n = 59) prior to catheter insertion. Randomization was carried out by assigning patients to groups week-wise. Endpoints of the investigation were skin colonization of the catheter site counted in colony forming units per swab at three time points: (1) prior to catheter insertion, on untreated skin; (2) directly after catheter insertion, prior to sterile coverage; (3) 48 h after catheter insertion. The hypothesis was tested by a Wilcoxon test with a two-sided alpha = 5 %. From second to third swab, recolonization of the catheter-surrounding skin was significantly lower in the trial group for both sorts of catheters: delta 2-3 OCT group: 0.72 (95 % CI: 0.42; 1.02); delta 2-3 BAC group: 1.97 (95 % CI: 1.45; 2.50); p < 0.001. None of the patients enrolled developed a catheter-related blood stream infection (CRBSI) during follow-up. Previous studies have shown that skin colonization is strongly associated with the occurrence of CRBSI. This randomized controlled trial supports the observations made in previous trials that octenidine dihydrochloride in disinfectants is more effective than agents

  14. Validation of a Low Cost, Disposable, and Ultrasound-guided Suprapubic Catheter Insertion Trainer.

    Science.gov (United States)

    Nonde, James; Adam, Ahmed; Laher, Abdullah Ebrahim

    2018-02-27

    To validate the newly designed ultrasound-guided suprapubic catheter insertion trainer (US-SCIT) model against the real life experience by enrolling participants with prior confidence in the technique of US-guided suprapubic catheter (SPC) insertion. The US-SCIT was self-constructed from common disposables and equipment found in the emergency department. A validation questionnaire was completed by all participants after SPC insertion on the US-SCIT model. Fifty participants enrolled in the study. Each participant had reported confidence in the SPC insertion technique, prior to participation in this study. There were 13 "super-users" (>65 previous successful real life SPC insertions) in the study. The total material cost per US-SCIT unit was 1.71 USD. The US-SCIT's value in understanding the principals of US-guided SPC insertion had a mean score of 8.86 (standard deviation [SD] 1.03), whereas its value in simulating contextual anatomy had a mean score of 8.26 (SD 1.48). The mean score of the model's ability to provide realistic sensory feedback was 8.12 (SD 1.78), whereas that of realism of initial urine outflow was 9.06 (SD 1.20). Simulation with the model compared well with real life SPC insertion, with a mean score of 8.30 (SD1.48). The US-SCIT model performed well in various spheres developed to assess its ability to simulate real life SPC insertion. We are confident that this low-cost, validated, US compatible SPC trainer, constructed from common material present in the ED, will be a valuable learning asset to trainees across the globe. Copyright © 2018 Elsevier Inc. All rights reserved.

  15. Acesso vascular para hemodiálise com cateter temporário de duplo lúmen em cães com insuficiência renal aguda Hemodialysis vascular access with temporary double-lumen catheter in dogs with acute renal failure

    Directory of Open Access Journals (Sweden)

    Alessandra Melchert

    2008-08-01

    Full Text Available A hemodiálise é uma modalidade terapêutica que pode sustentar a vida do paciente com insuficiência renal aguda (IRA, enquanto este recupera a função renal. Para sua realização, é necessário estabelecer circulação extracorpórea, para que seja realizada a filtração do sangue, impondo a necessidade de um acesso vascular viável e eficiente. O objetivo deste estudo foi avaliar a eficiência e as complicações do acesso vascular para hemodiálise (HD, com cateter temporário de duplo lúmen inserido na veia jugular externa. Foram estudados 10 cães com IRA induzida por gentamicina, submetidos a sessões diárias de HD, com duração de uma hora, até a recuperação da função renal ou óbito. Foram realizadas 104 sessões de HD nos animais estudados, observando-se necessidade de troca do cateter em sete sessões (6,7%, devido à obstrução do lúmen do cateter em seis sessões (5,8% ou por saída acidental do mesmo em uma sessão (1,0%. Não se observou migração do cateter, infecção, hemorragia ou hematoma no local de entrada do cateter na pele, obtendo-se fluxo sanguíneo patente em 90,4% das sessões. Concluiu-se que o acesso vascular na veia jugular externa com cateter temporário de duplo-lúmen mostrou-se viável, com ocorrência de poucas complicações, sendo, portanto, indicado como forma de acesso para a circulação extracorpórea para HD em cães com IRA.Hemodialysis is a therapeutic procedure that can sustain the patient's life in acute renal failure (ARF, during the renal function recover. To perform hemodialysis (HD, an extracorporeal circulation is established to blood filtration, imposing the need of a viable and efficient vascular access. The aim of this study was to evaluate the effectiveness and complications of the HD vascular access with temporary double-lumen catheter inserted into the external jugular vein. Ten mongrel dogs with ARF, induced by gentamicin administration, were submitted to daily

  16. Randomised Controlled Trial to determine the appropriate time to initiate peritoneal dialysis after insertion of catheter to minimise complications (Timely PD study

    Directory of Open Access Journals (Sweden)

    Fassett Robert G

    2010-06-01

    Full Text Available Abstract Background The most appropriate time to initiate dialysis after surgical insertion of Tenckhoff catheters is not clear in the literature. There is the possibility of peritoneal dialysis (PD complications such as leakage and infection if dialysis is started too soon after insertion. However, much morbidity and expense could be saved by reducing dependency on haemodialysis (HD by earlier initiation of PD post catheter insertion. Previous studies are observational and mostly compare immediate with delayed use. The primary objective is to determine the safest and shortest time interval between surgical placement of a Tenckhoff catheter and starting PD. Methods/Design This is a randomised controlled trial of patients who will start PD after insertion of Tenckhoff catheter at Royal Brisbane and Women's Hospital (RBWH or Rockhampton Base Hospital (RBH who meet the inclusion criteria. Patients will be stratified by site and diabetic status. The patients will be randomised to one of three treatment groups. Group 1 will start PD one week after Tenckhoff catheter insertion, group 2 at two weeks and group 3 at four weeks. Nurses and physicians will be blinded to the randomised allocation. The primary end point is the complication rate (leaks and infection after initiation of PD. Discussion The study will determine the most appropriate time to initiate PD after placement of a Tenckhoff catheter. Trial Registration ACTRN12610000076077

  17. Applications and complications of subclavian vein catheterization for hemodialysis

    International Nuclear Information System (INIS)

    Kamran, T.; Zaheer, K.; Khan, A.A.; Khalid, M.; Akhtar, M.S.

    2003-01-01

    Objective: To study the indications, complications and duration of 605 subclavian catheters inserted over a period of 4 years as venous access for the management of renal failure in local setup. Results: Among the patients who underwent subclavian vien catheterization, 75.2% patients were suffering from chronic renal failure and 24.7% patients were admitted for acute renal failure. Among chronic renal failure patients, 21.9% catheters had to be replaced due to various complications e.g. thrombosis, infection or kinking of the catheter. The subclavian catheters remained in place for a mean duration of 4 weeks. Early complications encountered were arterial puncture, inability to cannulate the innominate vein, hemo thorax, punctures of thoracic duct, hemo mediastinum, arrhythmias and pulmonary hematoma in 10.7%, 16.5%, 0.5%, 0.2%, 0.6% and 0.2% of patients respectively. Mortality attributed to the procedure occurred in 0.1 % cases. Delayed complications included early infection in 15% catheterizations while delayed infection occurred in 39 % cases. Conclusion: Percutaneous subclavian catheterization is valuable, relatively easy to learn and safe method with acceptable rate of complications for patients necessitating hemodialysis and no established permanent vascular access. (author)

  18. Nosocomial infective endocarditis in Hemodialysis

    International Nuclear Information System (INIS)

    Bhat, A.W.; Solangi, S.; Murtada, O.

    2002-01-01

    There is an increased risk of infective endocarditis catheterization usedfor Hemodialysis. We report a case of a young man who had endocarditissecondary to the use of a permanent jugular catheter for hemodialysis. Bloodcultures were repeatedly negative, but vegetations were seen on the tricuspidvalve on echocardiography. A high index of suspicion is recommended for thisserious complication. (author)

  19. Peripherally Inserted Central Catheter-Related Infections in a Cohort of Hospitalized Adult Patients

    Energy Technology Data Exchange (ETDEWEB)

    Bouzad, Caroline, E-mail: caroline.bouzad@gmail.com [Percy Military Teaching Hospital, Radiology Department (France); Duron, Sandrine, E-mail: duronsandrine@yahoo.fr [GSBdD, Military Centre for Epidemiology and Public Health (CESPA) (France); Bousquet, Aurore, E-mail: aurorebousquet@yahoo.fr [Begin Military Teaching Hospital, Bacteriology Department (France); Arnaud, François-Xavier, E-mail: fxa0160@hotmail.com [Percy Military Teaching Hospital, Radiology Department (France); Valbousquet, Laura, E-mail: laura.valbousquet@gmail.com [Begin Military Teaching Hospital, Radiology Department (France); Weber-Donat, Gabrielle, E-mail: weberdonatgabrielle@yahoo.fr; Teriitehau, Christophe, E-mail: cteriitehau@me.com; Baccialone, Jacques, E-mail: jacques.baccialone@wanadoo.fr; Potet, Julien, E-mail: potet-julien@yahoo.fr [Percy Military Teaching Hospital, Radiology Department (France)

    2016-03-15

    PurposeTo determine the incidence and the risks factors of peripherally inserted central catheter (PICC)-related infectious complications.Materials and MethodsMedical charts of every in-patient that underwent a PICC insertion in our hospital between January 2010 and October 2013 were reviewed. All PICC-related infections were recorded and categorized as catheter-related bloodstream infections (CR-BSI), exit-site infections, and septic thrombophlebitis.ResultsNine hundred and twenty-three PICCs were placed in 644 unique patients, mostly male (68.3 %) with a median age of 58 years. 31 (3.4 %) PICC-related infections occurred during the study period corresponding to an infection rate of 1.64 per 1000 catheter-days. We observed 27 (87.1 %) CR-BSI, corresponding to a rate of 1.43 per 1000 catheter-days, 3 (9.7 %) septic thrombophlebitis, and 1 (3.2 %) exit-site infection. Multivariate logistic regression analysis showed a higher PICC-related infection rate with chemotherapy (odds ratio (OR) 7.2–confidence interval (CI) 95 % [1.77–29.5]), auto/allograft (OR 5.9–CI 95 % [1.2–29.2]), and anti-coagulant therapy (OR 2.2–95 % [1.4–12]).ConclusionChemotherapy, auto/allograft, and anti-coagulant therapy are associated with an increased risk of developing PICC-related infections.Clinical AdvanceChemotherapy, auto/allograft, and anti-coagulant therapy are important predictors of PICC-associated infections. A careful assessment of these risk factors may be important for future success in preventing PICC-related infections.

  20. Peripherally Inserted Central Catheter-Related Infections in a Cohort of Hospitalized Adult Patients

    International Nuclear Information System (INIS)

    Bouzad, Caroline; Duron, Sandrine; Bousquet, Aurore; Arnaud, François-Xavier; Valbousquet, Laura; Weber-Donat, Gabrielle; Teriitehau, Christophe; Baccialone, Jacques; Potet, Julien

    2016-01-01

    PurposeTo determine the incidence and the risks factors of peripherally inserted central catheter (PICC)-related infectious complications.Materials and MethodsMedical charts of every in-patient that underwent a PICC insertion in our hospital between January 2010 and October 2013 were reviewed. All PICC-related infections were recorded and categorized as catheter-related bloodstream infections (CR-BSI), exit-site infections, and septic thrombophlebitis.ResultsNine hundred and twenty-three PICCs were placed in 644 unique patients, mostly male (68.3 %) with a median age of 58 years. 31 (3.4 %) PICC-related infections occurred during the study period corresponding to an infection rate of 1.64 per 1000 catheter-days. We observed 27 (87.1 %) CR-BSI, corresponding to a rate of 1.43 per 1000 catheter-days, 3 (9.7 %) septic thrombophlebitis, and 1 (3.2 %) exit-site infection. Multivariate logistic regression analysis showed a higher PICC-related infection rate with chemotherapy (odds ratio (OR) 7.2–confidence interval (CI) 95 % [1.77–29.5]), auto/allograft (OR 5.9–CI 95 % [1.2–29.2]), and anti-coagulant therapy (OR 2.2–95 % [1.4–12]).ConclusionChemotherapy, auto/allograft, and anti-coagulant therapy are associated with an increased risk of developing PICC-related infections.Clinical AdvanceChemotherapy, auto/allograft, and anti-coagulant therapy are important predictors of PICC-associated infections. A careful assessment of these risk factors may be important for future success in preventing PICC-related infections

  1. Is guidewire exchange a better approach for subclavian vein re-catheterization for chronic hemodialysis patients?

    Science.gov (United States)

    Hou, Shaw-Min; Chou, Po-Ching; Huang, Chi-Hung; Chin, Chih-Hui; Wang, Pa-Chun; Chen, Ya-Hui

    2006-01-01

    The objectives of this study were to compare outcomes and survival rates of subclavian vein re-catheterization through guide wire exchange (GWE) or de novo insertion (DN). The study was conducted in a retrospective manner. Medical records of 36 patients who received percutaneous subclavian vein re-catheterization for hemodialysis in our institution during the period from April 1, 2001 to September 30, 2004 were reviewed. All patients had at least 2 catheter insertions records in our institute. Incidences of adverse events (infection, thrombosis) were compared between GWE and DN groups using x2 test. Predictors for adverse event occurrences were analyzed using logistic regression models. Cox proportional hazard model was used to investigate the predictors for adverse event-free catheter days. Kaplan-Meire survival curves were computed and compared using log rank test. Information were generated from 98 catheters (41 from DN, 57 from GWE groups). The average catheter usage was 2.8+/-0.9 devices per patient and the mean catheter-indwelling-day was 125.4+/-129.5 days in this cohort. We found GWE group had significantly lower thrombosis rate (49.1% vs. 85.4% for DN group, Prates for GWE were > or =30 days, 85.4%; > or =60 days, 75.5%; > or =90 days, 64.5%; > or =180 days, 44.3%. The actuarial survival rates for DN were > or =30 days, 70.7%; > or =60 days, 58.5%; > or =90 days, 34.2%; > or =180 days, 18.4%. GWE group catheters had significantly higher catheter survival rates (P=0.0009). Mahukar catheter (hazard ratio 0.514, P=0.03), non-shock (hazard ratio 3.358, P=0.04), and older age (hazard ratio 0.958, P=0.026) were predictors of adverse event-free remaining catheter days. We suggest that GWE might be a favorable option over DN insertion when revised subclavian vein catheterization is inevitable. GWE can be performed repeatedly without compromising catheter outcomes.

  2. Peripherally inserted central catheters and upper extremity deep vein thrombosis

    International Nuclear Information System (INIS)

    Ong, B.; Gibbs, H.; Catchpole, I.; Hetherington, R.; Harper, J.

    2006-01-01

    The purpose of the study was to determine the incidence and risk factors for venous thrombosis in patients with a peripherally inserted central catheter (PICC). A retrospective study of all upper extremity venous duplex scans was carried out in the Vascular Medicine department from year 2000 to 2002 inclusive. A chart review of positive scans was undertaken to identify possible thrombotic risk factors. Of 317 upper extremity venous duplex scans carried out, 115, or 32%, were positive for upper extremity deep vein thrombosis. Three main risk factors were identified - presence of a central line, malignancy and administration of chemotherapy. PICC were the most common central line present. Symptomatic thrombosis occurred in 7% of PICC inserted for chemotherapy compared with 1% of PICC inserted for other reasons. Ten per cent of the patients receiving chemotherapy through a PICC developed a thrombosis. The post-thrombotic syndrome was infrequent following upper extremity deep vein thrombosis. Patients receiving chemotherapy through a PICC are at increased risk of thrombosis. There may be a role for prophylactic low-dose anticoagulation in these high-risk patients

  3. Relationship between peripheral insertion site and catheter-related phlebitis in adult hospitalized patients: a systematic review.

    Science.gov (United States)

    Comparcini, Dania; Simonetti, Valentina; Blot, Stijn; Tomietto, Marco; Cicolini, Giancarlo

    2017-01-01

    To explore the relationship between the anatomical site of peripheral venous catheterization and risk of catheter-related phlebitis. Peripheral venous catheterization is frequently associated with phlebitis. Recent guidelines, recommend the use of an upper-extremity site for catheter insertion but no univocal consensus exists on the anatomical site with lower risk of phlebitis. Systematic review. We searched Medline (PubMed) and CINAHL (EBSCOhost) databases until the end of January 2017. We also reviewed the reference lists of retrieved articles and gray literature was excluded. Searches were limited to articles published in English with no restriction imposed to date of publication. The primary outcome was the incidence of phlebitis associated with anatomical site of peripheral catheterization. We included randomized controlled trials and observational studies on adult patients who required a peripheral catheter for the administration of medi- cation, intermittent or continuous fluid infusion. Antecubital fossa veins are associated with lower phlebitis rates, while hands veins are the most risky sites to develop phlebitis. There is no consensus regarding vein in forearm. Choosing the right anatomical site to insert a peripheral venous catheter is important to decrease phlebitis rate. Further studies should compare indwelling time in different anatomical sites with phlebitis rate. A more standardized approach in defining and assessing phlebitis among studies is recommended.

  4. Peripheral venous catheter insertion simulation training: A randomized controlled trial comparing performance after instructor-led teaching versus peer-assisted learning.

    Science.gov (United States)

    Pelloux, Sophie; Grégoire, Arnaud; Kirmizigul, Patrice; Maillot, Sandrine; Bui-Xuan, Bernard; Llorca, Guy; Boet, Sylvain; Lehot, Jean-Jacques; Rimmelé, Thomas

    2017-12-01

    Peripheral venous catheter insertion is a procedural skill that every medical student should master. Training is often limited to a small number of students and is poorly evaluated. The objective of this study was to evaluate the performance of peer-assisted learning in comparison to instructor-led teaching for peripheral venous catheter insertion training. Students were randomized to the control group attending a traditional instructor-led training session (slideshow and demonstration by an anesthetist instructor, followed by training on a procedural simulator) or to the test group attending a peer-assisted training session (slideshow and demonstration video-recorded by the same instructor, followed by training on a procedural simulator). The primary endpoint was the performance of peripheral venous catheter insertion, assessed on procedural simulator one week later by blinded experts using a standardized 20-item grid. Students self-evaluated their confidence levels using a numeric 10-point scale. Eighty-six students were included, 73 of whom attended the assessment session. The median performance score was 12/20 [8-15] in the instructor-led teaching group versus 13/20 [11-15] in the peer-assisted learning group (P=0.430). Confidence levels improved significantly after the assessment session and were significantly higher in the peer-assisted learning group (7.6/10 [7.0-8.0] versus 7.0/10 [5.0-8.0], P=0.026). Peer-assisted learning is effective for peripheral venous catheter insertion training and can be as effective as instructor-led teaching. Given the large number of students to train, this finding is important for optimizing the cost-effectiveness of peripheral venous catheter insertion training. Copyright © 2017 Société française d’anesthésie et de réanimation (Sfar). Published by Elsevier Masson SAS. All rights reserved.

  5. Comparison of conventional straight and swan-neck straight catheters inserted by percutaneous method for continuous ambulatory peritoneal dialysis: a single-center study.

    Science.gov (United States)

    Singh, Shivendra; Prakash, Jai; Singh, R G; Dole, P K; Pant, Pragya

    2015-10-01

    To evaluate the incidence of mechanical and infectious complications of conventional straight catheter (SC) versus swan-neck straight catheter (SNSC) implanted by percutaneous method. We retrospectively analyzed 45 catheter insertions being done by percutaneous method from January 1, 2011, to May 31, 2014. SC was inserted in 24 patients, and SNSC was inserted in 21 patients. Baseline characteristics for the two groups were similar with respect to age, sex and diabetic nephropathy as the cause for end-stage renal disease. Incidence of mechanical and infectious complications in SNSC group was found to be low as compared to the SC group and was statistically significant (1 in 11.6 patient months vs. 1 in 14.4 patient months, p = 0.02). Catheter migration was found to be the most common mechanical complication (20 %), and peritonitis was found to be the most common infectious complication in conventional SC group (27 episodes in 420 patient months vs. 11 episodes in 333 patient months, p = 0.03). The incidence of exit site and tunnel infection rates revealed no difference between the groups. SNSC insertion by percutaneous method is associated with low mechanical and infectious complications.

  6. Percutaneous Placement of Central Venous Catheters: Comparing the Anatomical Landmark Method with the Radiologically Guided Technique for Central Venous Catheterization Through the Internal Jugular Vein in Emergent Hemodialysis Patients

    Energy Technology Data Exchange (ETDEWEB)

    Koroglu, M.; Demir, M.; Koroglu, B.K.; Sezer, M.T.; Akhan, O.; Yildiz, H.; Yavuz, L.; Baykal, B.; Oyar, O. [Suleyman Demirel Univ., Isparta (Turkey). Depts. of Radiology, Internal Medicine and Anesthesiology

    2006-02-15

    Purpose: To compare the success and immediate complication rates of the anatomical landmark method (group 1) and the radiologically (combined real-time ultrasound and fluoroscopy) guided technique (group 2) in the placement of central venous catheters in emergent hemodialysis patients. Material and Methods: The study was performed prospectively in a randomized manner. The success and immediate complication rates of radiologically guided placement of central venous access catheters through the internal jugular vein (n = 40) were compared with those of the anatomical landmark method (n 40). The success of placement, the complications, the number of passes required, and whether a single or double-wall puncture occurred were also noted and compared. Results: The groups were comparable in age and sex. The indication for catheter placement was hemodialysis access in all patients. Catheter placement was successful in all patients in group 2 and unsuccessful in 1 (2.5%) patient in group 1. All catheters functioned adequately and immediately after the placement (0% initial failure rate) in group 2, but 3 catheters (7.5% initial failure rate) were non-functional just after placement in group 1. The total number of needle passes, double venous wall puncture, and complication rate were significantly lower in group 2. Conclusion: Percutaneous central venous catheterization via the internal jugular vein can be performed by interventional radiologists with better technical success rates and lower immediate complications. In conclusion, central venous catheterization for emergent dialysis should be performed under both real-time ultrasound and fluoroscopic guidance.

  7. Catheter Angiography

    Medline Plus

    Full Text Available ... few millimeters) in the skin where the catheter can be inserted into an artery. The catheter is ... need for surgery. If surgery remains necessary, it can be performed more accurately. Catheter angiography presents a ...

  8. Catheter Angiography

    Medline Plus

    Full Text Available ... resonance imaging (MRI) In catheter angiography, a thin plastic tube, called a catheter , is inserted into an ... The catheter used in angiography is a long plastic tube about as thick as a strand of ...

  9. A comparison of buffered lidocaine versus ELA-Max before peripheral intravenous catheter insertions in children.

    Science.gov (United States)

    Luhmann, Janet; Hurt, Sarah; Shootman, Mario; Kennedy, Robert

    2004-03-01

    Peripheral intravenous catheter (PIV) insertion is a common, painful experience for many children in the pediatric emergency department. Although local anesthetics such as injected buffered lidocaine have been shown to be effective at reducing pain and anxiety associated with PIV insertion, they are not routinely used. ELA-Max, a topical local anesthetic, has the advantage of needle-free administration but has not been compared with buffered lidocaine for PIV insertion. To compare the reduction of pain and anxiety during PIV insertion provided by subcutaneous buffered 1% lidocaine or topical ELA-Max in children. A randomized trial in children 4 to 17 years old undergoing PIV insertion with 22-gauge catheters was conducted. Children received either buffered lidocaine or ELA-Max. Buffered lidocaine was administered by using 30-gauge needles to inject 0.1 to 0.2 mL subcutaneously just before PIV insertion. ELA-Max was applied to the skin and occluded with Tegaderm 30 minutes before PIV insertion. Self-reported Visual Analog Scale (VAS) questionnaires (rating on a scale of 1-10; 1 = no pain, anxiety) were completed by patients and their parents before PIV insertion to assess baseline perceptions about pain and anxiety associated with PIV insertion and immediately after PIV insertion to assess pain and anxiety associated with the experience. After PIV insertion, the nurse who inserted the PIV also completed a VAS questionnaire assessing technical difficulty and satisfaction with the local anesthesia. A blinded observer also completed a VAS questionnaire to assess pain and anxiety associated with the PIV insertion. Data were analyzed by using chi2 and t tests. Sixty-nine subjects were enrolled, and questionnaires were competed by all (mean age: 12.1 +/- 4.5 years; 61% female). There were no differences for buffered lidocaine and ELA-Max groups in age, gender, race, prior IV experience, or baseline pain and anxiety. There were no significant differences between buffered

  10. Cefotaxime-heparin lock prophylaxis against hemodialysis catheter-related sepsis among Staphylococcus aureus nasal carriers

    Directory of Open Access Journals (Sweden)

    Anil K Saxena

    2012-01-01

    Full Text Available Staphylococcus aureus nasal carriers undergoing hemodialysis (HD through tunneled cuffed catheters (TCCs form a high-risk group for the development of catheter-related bloodstream infections (CRBSI and ensuing morbidity. The efficacy of antibiotic-locks on the outcomes of TCCs among S. aureus nasal carriers has not been studied earlier. Persistent nasal carriage was defined by two or more positive cultures for methicillin-susceptible (MSSA or methicillin-resistant (MRSA S. aureus of five standardized nasal swabs taken from all the participants dialyzed at a large out-patient HD center affiliated to a tertiary care hospital. Of 218 participants, 82 S. aureus nasal carriers dialyzed through TCCs (n = 88 were identified through April 2005 to March 2006 and randomized to two groups. Group I comprised of 39 nasal carriers who had TCCs (n = 41 "locked" with cefotaxime/heparin while group II included 43 patients with TCCs (n = 47 filled with standard heparin. The CRBSI incidence and TCC survival at 365 days were statistically compared between the two groups. A significantly lower CRBSI incidence (1.47 vs. 3.44/1000 catheter-days, P <0.001 and higher infection-free TCC survival rates at 365 days (80.5 vs. 40.4%, P <0.0001 were observed in the cefotaxime group compared with the stan-dard heparin group. However, no significant difference in MRSA-associated CRBSI incidence was observed between the two groups. Cefotaxime-heparin "locks" effectively reduced CRBSI-incidence associated with gram-positive cocci, including MSSA, among S. aureus nasal carriers. There remains a compelling requirement for antibiotic-locks effective against MRSA.

  11. A New Formula to Estimate the Length of Right Upper Extremity Vein from Elbow Crease to Carina Calculated by Peripherally Inserted Central Catheter Insertion through Right Basilic Vein Puncture

    International Nuclear Information System (INIS)

    Cho, Hyun Hwan; Jeon, Eui Yong; Lee, Hyun Jung; Lee, Hyun; Koh, Sung Hye; Choi, Sun Young; Lee, Kwan Seop; Yoon, Dae Young; Im, Hyoung June

    2012-01-01

    To measure the length of the upper extremity vein between the elbow crease and the carina (elbow crease to carina length, ECL), to facilitate the appropriate positioning of the tip of the peripherally inserted central catheter (PICC). A total of 124 patients (64 men and 60 women; mean age 65.2 ± 15.4 years; range, 21-90 years) inserted with PICC through the right basilic vein under fluoroscopy were included in this retrospective study. The ECL was determined as follows: ECL = (distance from elbow crease to puncture site) + (the catheter length of PICC) - (distance from carina to catheter tip on post-procedural chest radiograph). We analyzed the relationship between ECL and patient height. The mean ECL through right basilic vein was 42.07 ±4.03 cm (27.5 to 52.2 cm). ECL was found to be significantly correlated with patient height: ECL (cm) = 0.24 X patient height (cm) + 3.75. The formula developed in our study would be helpful for predicting the optimal catheter length during a blind bedside procedure of PICC via the right basilic vein.

  12. Coil embolization of internal mammary artery injured during central vein catheter and cardiac pacemaker lead insertion

    Energy Technology Data Exchange (ETDEWEB)

    Chemelli, A.P. [Department of Radiology, Innsbruck Medical University, Anichstrasse 35, 6020 Innsbruck (Austria)], E-mail: Andreas.Chemelli@i-med.ac.at; Chemelli-Steingruber, I.E. [Department of Radiology, Innsbruck Medical University, Anichstrasse 35, 6020 Innsbruck (Austria); Bonaros, N. [Department of Cardiovascular Surgery, Innsbruck Medical University (Austria); Luckner, G. [Department of Anaesthesiology and Critical Care Medicine, Innsbruck Medical University (Austria); Millonig, G. [Department of Gastroenterology and Hepatology, Innsbruck Medical University (Austria); Seppi, K. [Department of Neurology, Innsbruck Medical University (Austria); Lottersberger, C.; Jaschke, W. [Department of Radiology, Innsbruck Medical University, Anichstrasse 35, 6020 Innsbruck (Austria)

    2009-08-15

    Purpose: This study describes several cases of endovascular coil embolization of the proximal internal mammary artery injured by blind approach to the subclavian vein for central venous catheter or pacemaker lead insertion. Materials and methods: We conducted a retrospective analysis of five patients with iatrogenic arterial lesions of the internal mammary artery (IMA). The lesions occurred in three patients from a puncture of the subclavian vein during insertion of a central venous catheter and in two patients from a puncture of the subclavian vein for insertion of a pacemaker lead. Four patients had acute symptoms of bleeding with mediastinal hematoma and hematothorax and one patient was investigated in a chronic stage. A pseudoaneurysm was detected in all five patients. All four acute and hemodynamic unstable patients required hemodynamic support. Results: In all patients, embolization was performed using a coaxial catheter technique, and a long segment of the IMA adjacent distally and proximally to the source of bleeding was occluded with pushable microcoils. In one patient, additional mechanically detachable microcoils were used at the very proximal part of the IMA. Microcoil embolization of the IMA was successful in all patients, and the source of bleeding was eliminated in all patients. Conclusion: Transarterial coil embolization is a feasible and efficient method in treating acute bleeding and pseudoaneurysm of the IMA and should be considered if mediastinal hematoma or hemathorax occurs after blind puncture of the subclavian vein.

  13. Complications of central venous stenosis due to permanent central venous catheters in children on hemodialysis.

    Science.gov (United States)

    Rinat, Choni; Ben-Shalom, Efrat; Becker-Cohen, Rachel; Feinstein, Sofia; Frishberg, Yaacov

    2014-11-01

    Central venous catheters are frequently used as access for hemodialysis (HD) in children. One of the known complications is central venous stenosis. Although this complication is not rare, it is often asymptomatic and therefore unacknowledged. Superior vena cava (SVC) stenosis is obviously suspected in the presence of upper body edema, but several other signs and symptoms are often unrecognized as being part of this syndrome. We describe four patients with various manifestations of central venous stenosis and SVC syndrome. These sometimes life- or organ-threatening conditions include obstructive sleep apnea, unresolving stridor, increased intracranial pressure, increased intraocular pressure, right-sided pleural effusion, protein-losing enteropathy and lymphadenopathy. The temporal relationship of these complications associated with the use of central venous catheters and documentation of venous stenosis, together with their resolution after alleviation of high venous pressure, points to a causal role. We suggest pathophysiological mechanisms for the formation of each of these complications. In patients with occlusion of the SVC, various unexpected clinical entities can be caused by high central venous pressure. As often the etiology is not obvious, a high index of suspicion is needed as in some cases prompt alleviation of the high pressure is mandatory.

  14. Risk Factors of Catheter-related Bloodstream Infection With Percutaneously Inserted Central Venous Catheters in Very Low Birth Weight Infants: A Center's Experience in Taiwan

    Directory of Open Access Journals (Sweden)

    Jen-Fu Hsu

    2010-12-01

    Conclusion: It is important to avoid inserting a PICC at the femoral site. Strict catheter care protocol should also be applied to reduce local site bacterial colonization and removal of PICCs as soon as they are no longer essential for patient care to reduce the incidence of infection.

  15. Catheter Angiography

    Medline Plus

    Full Text Available ... lessen your anxiety during the procedure. The area of the groin or arm where the catheter will be inserted is shaved, ... contrast material is injected through the catheter and reaches the blood vessels being studied, several sets of x-rays are taken. Then the catheter is ...

  16. Severe neutropenia at time of port insertion is not a risk factor for catheter-associated infections in children with acute lymphoblastic leukemia.

    Science.gov (United States)

    Junqueira, Beatriz L P; Connolly, Bairbre; Abla, Oussama; Tomlinson, George; Amaral, Joao G

    2010-09-15

    The objective of this study was to determine whether severe neutropenia on the day of port-a-catheter (PORT) insertion was a risk factor for catheter-associated infection (CAI) in children with acute lymphoblastic leukemia (ALL). This was a retrospective study of children with ALL who had a PORT insertion between January 2005 and August 2008. Early (≤ 30 days) and late (>30 days) postprocedure complications were reviewed. The length of follow-up ranged between 7 months and 42 months. In total, 192 PORTs were inserted in 179 children. There were 43 CAIs (22%), and the infection rate was 0.35 per 1000 catheter-days. The CAI rate (15%) in children who had severe neutropenia on the day of the procedure did not differ statistically from the CAI rate (24%) in children who did not have severe neutropenia (P = .137). Conversely, patients with severe neutropenia who had a CAI were more likely to have their PORT removed (P = .019). The most common organisms to cause catheter removal were coagulase-negative Staphylococcus and Staphylococcus aureus. Patients with high-risk ALL had a statistically significant higher incidence of late CAI than patients with standard-risk ALL (P = .012). Age (P = .272), positive blood culture preprocedure (P = 1.0), and dexamethasone use (P = .201) were not risk factors for CAI. Patients who had an early CAI did not have a greater chance of having a late CAI. The catheter infection-free survival rate at 1 year was 88.6%. The current results indicated that severe neutropenia on the day of PORT insertion does not increase the risk of CAI in children with ALL. © 2010 American Cancer Society.

  17. A team-based multidisciplinary approach to managing peripherally inserted central catheter complications in high-risk haematological patients: a prospective study.

    Science.gov (United States)

    Curto-García, Natalia; García-Suárez, Julio; Callejas Chavarria, Marta; Gil Fernández, Juan José; Martín Guerrero, Yolanda; Magro Mazo, Elena; Marcellini Antonio, Shelly; Juárez, Luis Miguel; Gutierrez, Isabel; Arranz, Juan José; Montalvo, Irene; Elvira, Carmen; Domínguez, Pilar; Díaz, María Teresa; Burgaleta, Carmen

    2016-01-01

    Use of peripherally inserted central catheters (PICCs) has markedly increased during the last decade. However, there are few studies on use of PICCs in patients with haematological malignancies (HM) receiving intensive chemotherapy. Preliminary data suggest a higher rate of PICC-related complications in these high-risk patients. This prospective observational single-centre study aimed to investigate PICC-related complications after implementation of a multidisciplinary approach to PICC care and compared it with previous literature. A total of 44 PICCs were inserted in 36 patients (27.3%, thrombocytopenia <50 × 10(9)/L at insertion) over 5045 PICC days (median duration, 114.5 days). No major insertion-related complications were observed. Major late complications were obstruction in 13.6% (1.19/1000 PICC days) of patients, catheter-related bloodstream infection in 6.8% (0.59/1000 PICC days), and catheter-related thrombosis in 4.5% (0.39/1000 PICC days). Premature PICC removal occurred in 34% (2.97/1000 PICC days) of patients. The overall rate of potentially major dangerous complications was particularly low (11.36%, 0.99/1000 PICC days) compared with previous studies. This study highlights the utility of a multidisciplinary approach for PICC care in adults with HM receiving intensive chemotherapy. We provide further data to support use of PICCs in such patient populations.

  18. Variables decreasing tip movement of peripherally inserted central catheters in pediatric patients.

    Science.gov (United States)

    Gnannt, Ralph; Connolly, Bairbre L; Parra, Dimitri A; Amaral, Joao; Moineddin, Rahim; Thakor, Avnesh S

    2016-10-01

    The position of the tip of a peripherally inserted central catheter (PICC) is crucial; malposition can lead to malfunction of the line or life-threatening events (e.g., arrhythmias, perforation). To determine what factors other than arm position and accessed vein might influence the tip position of a PICC. Inclusion criteria were upper limb PICC placement, body weight central tip movement in rib units. We included 112 children who received a PICC (42 girls/70 boys, mean age 31±13 months, mean weight 6.5±4.9 kg). The overall range of central tip movement was -1 to +4 rib units (mean +0.8±0.7 rib units). Silicone PICCs moved significantly less than polyurethane PICCs (Pcentral tip movement of a PICC (P>0.05). Silicone PICCs and PICCs inserted into the cephalic vein move less than PICCs made of polyurethane and PICCs inserted into the brachial and basilic veins. These findings might assist operators in deciding which PICC to place in children in a given clinical context.

  19. Catheter Angiography

    Medline Plus

    Full Text Available ... imaging (MRI) In catheter angiography, a thin plastic tube, called a catheter , is inserted into an artery ... examined, a contrast material is injected through the tube and images are captured using a small dose ...

  20. Catheter Angiography

    Medline Plus

    Full Text Available ... incision in the skin. Once the catheter is guided to the area being examined, a contrast material ... inserted into an artery. The catheter is then guided through the arteries to the area to be ...

  1. Catheter Angiography

    Medline Plus

    Full Text Available ... catheter , is inserted into an artery through a small incision in the skin. Once the catheter is ... the tube and images are captured using a small dose of ionizing radiation ( x-rays ). top of ...

  2. Catheter Angiography

    Medline Plus

    Full Text Available ... an artery through a small incision in the skin. Once the catheter is guided to the area ... small incision (usually a few millimeters) in the skin where the catheter can be inserted into an ...

  3. Frequency of nursing care of vascular access in hemodialysis patients

    Directory of Open Access Journals (Sweden)

    Iman Taghizade Firoozjayi

    2016-03-01

    Full Text Available Background: Hemodialysis is a critical treatment method, which depends on the vascular access route. Lack of care for the vascular access route could diminish its efficiency in a short time. Regarding this, the present study aimed to evaluate the frequency of nursing care for vascular access route in the hemodialysis patients. Methods: This cross-sectional study was conducted on 20 nurses and 120 hemodialysis patients, who referred to the Hemodialysis Department of Shahid Beheshti Hospital, Babol, Iran, in 2015. The method of nursing care for vascular access route was evaluated using a researcher-made checklist. The data analysis was performed using the descriptive statistics in the SPSS version 16. Results: In total, 14 cases of nursing care were evaluated, in 100% of which all the caring steps, including wearing gloves and a mask, early bolus injections of heparin, washing the catheter tubing, frequent monitoring of blood pressure, rinsing the catheter tubing, returning the blood to the body after hemodialysis, and sterile covering of the puncture site, were observed. However, some of the other techniques, such as the care related to appropriate pump speed when starting the dialysis machine (81.66%, observance of the needle distance from fistula (75.83%, appropriate placement of catheter (75%, pressing the injection site (54.17%, blood pressure monitoring at the end of dialysis (50%, and change of the needle site between two sessions (27.5%, were not adhered to by the nurses. Conclusion: According to the results of this study, some of the nursing care steps, which are necessary in the beginning and end of the hemodialysis, were not accurately followed by the nurses. It is recommended that constant training courses be held for the nurses in this regard.

  4. Barriers and Facilitators to Central Venous Catheter Insertion: A Qualitative Study.

    Science.gov (United States)

    Cameron, Kenzie A; Cohen, Elaine R; Hertz, Joelle R; Wayne, Diane B; Mitra, Debi; Barsuk, Jeffrey H

    2018-03-14

    The aims of the study were to identify perceived barriers and facilitators to central venous catheter (CVC) insertion among healthcare providers and to understand the extent to which an existing Simulation-Based Mastery Learning (SBML) program may address barriers and leverage facilitators. Providers participating in a CVC insertion SBML train-the-trainer program, in addition to intensive care unit nurse managers, were purposively sampled from Veterans Administration Medical Centers located in geographically diverse areas. We conducted semistructured interviews to assess perceptions of barriers and facilitators to CVC insertion. Deidentified transcripts were analyzed using a grounded theory approach and the constant comparative method. We subsequently mapped identified barriers and facilitators to our SBML curriculum to determine whether or not the curriculum addresses these factors. We interviewed 28 providers at six Veterans Administration Medical Centers, identifying the following five overarching factors of perceived barriers to CVC insertion: (1) equipment, (2) personnel/staff, (3) setting or organizational context, (4) patient or provider, and (5) time-related barriers. Three overarching factors of facilitators emerged: (1) equipment, (2) personnel, and (3) setting or organizational context facilitators. The SBML curriculum seems to address most identified barriers, while leveraging many facilitators; building on the commonly identified facilitator of nursing staff contribution by expanding the curriculum to explicitly include nurse involvement could improve team efficiency and organizational culture of safety. Many identified facilitators (e.g., ability to use ultrasound, personnel confidence/competence) were also identified as barriers. Evidence-based SBML programs have the potential to amplify these facilitators while addressing the barriers by providing an opportunity to practice and master CVC insertion skills.

  5. Malfunctioning and infected tunneled infusion catheters: over-the-wire catheter exchange versus catheter removal and replacement.

    Science.gov (United States)

    Guttmann, David M; Trerotola, Scott O; Clark, Timothy W; Dagli, Mandeep; Shlansky-Goldberg, Richard D; Itkin, Maxim; Soulen, Michael C; Mondschein, Jeffrey I; Stavropoulos, S William

    2011-05-01

    To compare the safety and effectiveness of over-the-wire catheter exchange (catheter-exchange) with catheter removal and replacement (removal-replacement) at a new site for infected or malfunctioning tunneled infusion catheters. Using a quality assurance database, 61 patients with tunneled infusion catheters placed during the period July 2001 to June 2009 were included in this study. Patients receiving hemodialysis catheters were excluded. Catheter-exchange was performed in 25 patients, and same-day removal-replacement was performed in 36 patients. Data collected included demographic information, indication for initial catheter placement and replacement, dwell time for the new catheter, and ultimate fate of the new device. Statistical comparisons between the two cohorts were analyzed using the Kaplan-Meier technique and Fisher exact test. Catheters exchanged over the wire remained functional without infection for a median of 102 days (range, 2-570 days), whereas catheters removed and replaced were functional for a median 238 days (range, 1-292 days, P = .12). After catheter replacement, there were 11 instances of subsequent infection in the catheter-exchange group and 7 instances in the removal-replacement cohort, accounting for infection rates of 4.4 and 2.3 per 1,000 catheter days (P = .049). Patients in the catheter-exchange group had 3.2 greater odds of infection compared with patients in the removal-replacement group. Five malfunction events occurred in each group, accounting for 2.0 and 1.7 malfunctions per 1,000 catheter days in the catheter-exchange and removal-replacement groups (P = .73). Catheter-exchange of tunneled infusion catheters results in a higher infection rate compared with removal-replacement at a new site. The rate of catheter malfunction is not significantly different between the two groups. Catheter-exchange is an alternative for patients with tunneled infusion catheters who have limited venous access, but this technique should not be

  6. Safety related to the implantation of jugular catheters for haemodialysis and usefulness of PA chest X rays post procedure

    International Nuclear Information System (INIS)

    Restrepo, Cesar A; Chacon, Jose Arnob; Mauricio Villota, Duvan

    2007-01-01

    The objective is to determine how safe the implantation of transient double lumen jugular catheters is for hemodialysis in patients with renal disease, and who require dialysis therapy and Posterior Anterior (PA) chest X-Ray post procedure. Design: observational descriptive study. Site: renal units at RTS Ltda. Sucursal Caldas (Hospital Santa Sofia y Hospital Infantil Rafael Henao Toro de la Cruz Roja). Patients: all patients with renal disease in whom it was necessary to do hemodyalitic therapy with implantation of a jugular catheter, with medical records of the events and complications that occurred during the procedure, with subsequent control AP chest X Ray and that showed reports made by the radiologist or physician who carried out the procedure, about the findings in the chest X Ray. Patients with renal disease, in whom jugular catheters had been inserted: Methods: variables such as age, gender, race, body mass index (BMI) etiology of the renal failure,time of evolution of the disease, indications for insertion, priority of catheter insertion, type of catheter inserted, amount of punctures, physician who carried out the procedure and patient's co-morbidities were analyzed. The events considered as complicated were analyzed as well as if there was any relationship with co-morbidities and the analyzed variables. Findings in the PA chest X-Ray were recorded and their relationship with the difficulties encountered during the procedure. A bi-variance analysis was done. The dependent and independent variables were classified in the nominal measurement scale. Results: 774 clinical histories were reviewed. 562 were excluded due to lack of variables and impossibility to read the notes. Men older than de 55 (45,7%). 212 (97.1%) patients with diagnosis of chronic renal disease (CRD) and in whom 238 procedures were carried out. seven patients (2,85%) had acute renal failure (ARF). The fi rst indication for central catheter insertion was in patients with chronic uremia

  7. Comparison of complications between pediatric peripherally inserted central catheter placement techniques

    International Nuclear Information System (INIS)

    Dasgupta, Niloy; Lungren, Matthew P.; Patel, Manish N.; Racadio, John M.; Johnson, Neil D.

    2016-01-01

    Peripherally inserted central catheter (PICC) is among the most common procedures performed in children in the hospital setting. PICC insertion can be simplified with the use of a sheathed needle as an alternative to the modified Seldinger technique. To retrospectively evaluate PICC placement for the technique used and the incidence of complications at a large pediatric tertiary care center. We retrospectively reviewed all PICC placements at a single institution over a 4-year period. We reviewed patient records for demographic data, PICC placement technique, catheter size and number of lumens, and the incidence of complications (i.e. multiple attempted puncture sites, phlebitis and vessel thrombosis). We analyzed complication rates between two placement techniques using a chi-square test. We identified 8,816 successful PICC placements, 4,749 (53.9%) in males and 4,067 (46.1%) in females. The average age of the patients for which a line was placed was 5.6 years (range 1 day to 45 years). A direct sheathed needle puncture technique was used in 8,362 (94.9%) placements and a modified Seldinger technique was used in 454 (5.1%). Complications occurred in 312 (3.7%) of direct sheathed needle puncture placements versus 17 (3.7%) of modified Seldinger placements (P = 0.99). Multiple puncture sites were required in 175 (2.1%) attempted direct sheathed needle puncture placements compared with 8 (1.7%) attempted modified Seldinger placements (P = 0.63). Phlebitis occurred in 94 (1.1%) direct sheathed needle puncture lines versus 5 (1.1%) modified Seldinger placed lines (P = 0.96). Vessel thrombosis occurred in 43 (0.5%) direct sheathed needle puncture lines versus 4 (0.9%) modified Seldinger placed lines (P = 0.30). The direct peel-away sheathed needle vessel puncture technique and the modified Seldinger technique used to place PICC lines in children have similar complication rates. (orig.)

  8. Comparison of complications between pediatric peripherally inserted central catheter placement techniques

    Energy Technology Data Exchange (ETDEWEB)

    Dasgupta, Niloy; Lungren, Matthew P. [Lucile Packard Children' s Hospital Stanford, Department of Radiology, Palo Alto, CA (United States); Patel, Manish N.; Racadio, John M.; Johnson, Neil D. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati, OH (United States)

    2016-09-15

    Peripherally inserted central catheter (PICC) is among the most common procedures performed in children in the hospital setting. PICC insertion can be simplified with the use of a sheathed needle as an alternative to the modified Seldinger technique. To retrospectively evaluate PICC placement for the technique used and the incidence of complications at a large pediatric tertiary care center. We retrospectively reviewed all PICC placements at a single institution over a 4-year period. We reviewed patient records for demographic data, PICC placement technique, catheter size and number of lumens, and the incidence of complications (i.e. multiple attempted puncture sites, phlebitis and vessel thrombosis). We analyzed complication rates between two placement techniques using a chi-square test. We identified 8,816 successful PICC placements, 4,749 (53.9%) in males and 4,067 (46.1%) in females. The average age of the patients for which a line was placed was 5.6 years (range 1 day to 45 years). A direct sheathed needle puncture technique was used in 8,362 (94.9%) placements and a modified Seldinger technique was used in 454 (5.1%). Complications occurred in 312 (3.7%) of direct sheathed needle puncture placements versus 17 (3.7%) of modified Seldinger placements (P = 0.99). Multiple puncture sites were required in 175 (2.1%) attempted direct sheathed needle puncture placements compared with 8 (1.7%) attempted modified Seldinger placements (P = 0.63). Phlebitis occurred in 94 (1.1%) direct sheathed needle puncture lines versus 5 (1.1%) modified Seldinger placed lines (P = 0.96). Vessel thrombosis occurred in 43 (0.5%) direct sheathed needle puncture lines versus 4 (0.9%) modified Seldinger placed lines (P = 0.30). The direct peel-away sheathed needle vessel puncture technique and the modified Seldinger technique used to place PICC lines in children have similar complication rates. (orig.)

  9. FACTORS AND COMPLICATIONS AFFECTING CATHETER AND TECHNIQUE SURVIVAL WITH PERMANENT SINGLE-LUMEN DIALYSIS CATHETERS

    NARCIS (Netherlands)

    DEMEESTER, J; VANHOLDER, R; DEROOSE, J; RINGOIR, S

    1994-01-01

    This long-term study on the outcome of permanent silicone single-lumen dialysis catheters consisted of 43 surgically inserted catheters in 33 patients. All catheters were attached to a pressure-pressure single-cannula dialysis system. Technique and catheter survival were 80 and 59% at 1 year, and 63

  10. Radiologic placement of Hickman catheters

    International Nuclear Information System (INIS)

    Robertson, L.J.; Mauro, M.A.; Jaques, P.F.

    1988-01-01

    Hickman catheter inserter has previously been predominantly accomplished surgically by means of venous cutdown or percutaneous placement in the operating room. The authors describe their method and results for 55 consecutive percutaneous placements of Hickman catheters in the interventional radiology suite. Complication rates were comparable to those for surgical techniques. Radiologic placement resulted in increased convenience, decreased time and cost of insertion, and super fluoroscopic control of catheter placement and any special manipulations. Modern angiographic materials provide safer access to the subclavian vein than traditional methods. The authors conclude that radiologic placement of Hickman catheters offers significant advantages over traditional surgical placement

  11. Central Venous Occlusion in the Hemodialysis Patient.

    Science.gov (United States)

    Krishna, Vinay Narasimha; Eason, Joseph B; Allon, Michael

    2016-11-01

    Central venous stenosis (CVS) is encountered frequently among hemodialysis patients. Prior ipsilateral central venous catheterization and cardiac rhythm device insertions are common risk factors, but CVS can also occur in the absence of this history. Chronic CVS can cause thrombosis with partial or complete occlusion of the central vein at the site of stenosis. CVS is frequently asymptomatic and identified as an incidental finding during imaging studies. Symptomatic CVS presents most commonly as an upper- or lower-extremity edema ipsilateral to the CVS. Previously unsuspected CVS may become symptomatic after placement of an ipsilateral vascular access. The likelihood of symptomatic CVS may be affected by the central venous catheter (CVC) location; CVC side; duration of CVC dependence; type, location, and blood flow of the ipsilateral access; and extent of collateral veins. Venous angiography is the gold standard for diagnosis. Percutaneous transluminal angioplasty and stent placement can improve the stenosis and alleviate symptoms, but CVS typically recurs frequently, requiring repeated interventions. Refractory symptomatic CVS may require ligation of the ipsilateral vascular access. Because no available treatment option is curative, the goal should be to prevent CVS by minimizing catheters and central vein instrumentation in patients with chronic kidney disease and dialysis patients. Copyright © 2016 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.

  12. Surgical Management of Multiple Valve Endocarditis Associated with Dialysis Catheter

    Directory of Open Access Journals (Sweden)

    R. Zea-Vera

    2016-01-01

    Full Text Available Endocarditis associated with dialysis catheter is a disease that must be suspected in every patient with hemodialysis who develops fever. Multiple valve disease is a severe complication of endocarditis that needs to be managed in a different way. There is very limited data for treatment and every case must be considered individually. We present a patient with this complication and describe the medical treatment and surgical management. We report the case of a 15-year-old patient with acute renal failure that develops trivalvular endocarditis after the hemodialysis catheter was placed, with multiple positive blood culture for Staphylococcus aureus. Transesophageal echocardiography was done and aortic and tricuspid valvular vegetations and mitral insufficiency were reported. Patient was successfully treated by surgery on the three valves, including aortic valve replacement. There is limited data about the appropriate treatment for multiple valvular endocarditis; it is important to consider this complication in the setting of hemodialysis patients that develop endocarditis and, despite the appropriate treatment, have a torpid evolution. In countries where endovenous drug abuse is uncommon, right sided endocarditis is commonly associated with vascular catheters. Aggressive surgical management should be the treatment of choice in these kinds of patients.

  13. Insertion of an active fixation lead in the inferior interatrial septum via a 9.0 Fr guiding catheter

    Directory of Open Access Journals (Sweden)

    Shumpei Mori, MD

    2014-04-01

    Full Text Available Placing an atrial lead in the inferior interatrial septum (IAS reportedly reduces the incidence of paroxysmal atrial fibrillation (AF and slows the progression to chronic AF; however, in certain cases, inferior IAS pacing is technically difficult. When this procedure is unsuccessful, insertion of the lead in the right atrial appendage can be considered, but it is associated with a risk of cardiac perforation. Here, we describe a technique for lead insertion in the inferior IAS via a 9.0 Fr guiding catheter, which may serve as an alternative technique for inferior IAS pacing when the conventional stylet-guided insertion is not successful.

  14. Impact of ultrasonography on central venous catheter insertion in intensive care

    International Nuclear Information System (INIS)

    Palepu, Gopal B; Deven, Juneja; Subrahmanyam, M; Mohan, S

    2009-01-01

    The insertion of central venous catheters (CVCs) is an integral part of the management of critically ill patients. We aimed to study the impact of ultrasonography (USG) on CVC insertion in intensive care. A prospective study of 450 patients requiring CVC in the intensive care unit (ICU) of a tertiary care hospital. The patients were randomized into two groups: to have CVC insertion with USG-guidance or with the anatomic landmark technique (ALT). Data were collected on patient demographics; operator experience; and method, site and side of insertion. Outcome measures included successful insertion of CVC, number of attempts needed and complications. Internal jugular vein (IJV) cannulation was successful in 177/194 patients (91.2%) using ALT and in 200/205 patients (97.6%) using USG guidance, a significant difference of 6.4% (P = 0.006). Using ALT, 72.7% of cannulations could be accomplished in the first attempt as compared with 84.4% with USG guidance (P = 0.004). The overall complication rate was 28/399 (7%), with 19 (9.8%) complications in the ALT group and 9 (4.4%) in the USG group (age-, sex-, and operator-adjusted OR = 0.35, 95% CI: 0.13–0.96; P = 0.03). For subclavian vein catheterization, the success rate was 26/28 (92.9%) in the ALT group and 17/17 (100%) in the USG group (P = 0.52). Using ALT, 71.4% cannulation could be accomplished in the first attempt as compared with 82.4% under USG guidance (P = 0.49). The overall complication rate was 6/45 (13.3%), with 4 (14.3%) complications in the ALT group and 2 (11.8%) in the USG group (P > 0.99). Real-time USG guidance improves success rates, reduces the number of attempts and decreases the complications associated with CVC insertion, especially for the IJV, and should become the standard of care in intensive care

  15. Incremental short daily home hemodialysis: a case series.

    Science.gov (United States)

    Toth-Manikowski, Stephanie M; Mullangi, Surekha; Hwang, Seungyoung; Shafi, Tariq

    2017-07-05

    Patients starting dialysis often have substantial residual kidney function. Incremental hemodialysis provides a hemodialysis prescription that supplements patients' residual kidney function while maintaining total (residual + dialysis) urea clearance (standard Kt/Vurea) targets. We describe our experience with incremental hemodialysis in patients using NxStage System One for home hemodialysis. From 2011 to 2015, we initiated 5 incident hemodialysis patients on an incremental home hemodialysis regimen. The biochemical parameters of all patients remained stable on the incremental hemodialysis regimen and they consistently achieved standard Kt/Vurea targets. Of the two patients with follow-up >6 months, residual kidney function was preserved for ≥2 years. Importantly, the patients were able to transition to home hemodialysis without automatically requiring 5 sessions per week at the outset and gradually increased the number of treatments and/or dialysate volume as the residual kidney function declined. An incremental home hemodialysis regimen can be safely prescribed and may improve acceptability of home hemodialysis. Reducing hemodialysis frequency by even one treatment per week can reduce the number of fistula or graft cannulations or catheter connections by >100 per year, an important consideration for patient well-being, access longevity, and access-related infections. The incremental hemodialysis approach, supported by national guidelines, can be considered for all home hemodialysis patients with residual kidney function.

  16. Dialysis catheter-related superior vena cava syndrome with patent vena cava: Long term efficacy of unilateral viatorr stent-graft avoiding catheter manipulation

    Energy Technology Data Exchange (ETDEWEB)

    Quaretti, Pietro; Galli, Franco; Maramarco, Lorenzo Paplo; Corti, Riccardo; Leati, Giovanni; Fiorina, Ilaria; Maestri, Marcello [IRCCS Policlinico San Matteo Foundation, Pavia (Italy)

    2014-06-15

    Central venous catheters are the most frequent causes of benign central vein stenosis. We report the case of a 79-year-old woman on hemodialysis through a twin catheter in the right internal jugular vein, presenting with superior vena cava (SVC) syndrome with patent SVC. The clinically driven endovascular therapy was conducted to treat the venous syndrome with a unilateral left brachiocephalic stent-graft without manipulation of the well-functioning catheter. The follow-up was uneventful until death 94 months later.

  17. Dialysis catheter-related superior vena cava syndrome with patent vena cava: Long term efficacy of unilateral viatorr stent-graft avoiding catheter manipulation

    International Nuclear Information System (INIS)

    Quaretti, Pietro; Galli, Franco; Maramarco, Lorenzo Paplo; Corti, Riccardo; Leati, Giovanni; Fiorina, Ilaria; Maestri, Marcello

    2014-01-01

    Central venous catheters are the most frequent causes of benign central vein stenosis. We report the case of a 79-year-old woman on hemodialysis through a twin catheter in the right internal jugular vein, presenting with superior vena cava (SVC) syndrome with patent SVC. The clinically driven endovascular therapy was conducted to treat the venous syndrome with a unilateral left brachiocephalic stent-graft without manipulation of the well-functioning catheter. The follow-up was uneventful until death 94 months later.

  18. Utilization of a biomedical device (VeinViewer® ) to assist with peripheral intravenous catheter (PIV) insertion for pediatric nurses.

    Science.gov (United States)

    McNeely, Heidi L; Ream, Theresa L; Thrasher, Jodi M; Dziadkowiec, Oliwier; Callahan, Tiffany J

    2018-04-01

    Vascular access in pediatric patients can be challenging even with the currently available technological resources. This nurse-driven research study explored time, cost, and resources for intravenous access to determine if a biomedical device, VeinViewer ® Vision, would facilitate improvements in pediatric access. In addition, this study looked at nurse perceptions of skills and confidence around intravenous insertion and if the use of the VeinViewer ® impacted these perceptions. Literature examining pediatric intravenous access success rates compared with nurse perceived skills and confidence is lacking. Nonblinded randomized control trial of pediatric nurses working in an acute care hospital setting. A preliminary needs assessment solicited feedback from nurses regarding their practice, perceived skills, and confidence with placing peripheral intravenous catheters (PIVs). Due to the results of the preliminary needs assessment, a research study was designed and 40 nurses were recruited to participate. The nurses were randomized into either a VeinViewer ® or standard practice group. Nurse participants placed intravenous catheters on hospitalized pediatric patients using established procedures while tracking data for the study. Needs assessment showed a majority of nurses felt a biomedical device would be helpful in building their intravenous insertion skills and their confidence. The study results did not demonstrate any clinically significant differences between VeinViewer ® use and standard practice for intravenous catheter insertion in pediatric patients for success of placement, number of attempts, or overall cost. In addition, no difference was noted between nurses in either group on perceived skills or confidence with insertion of PIVs. The ongoing need for resources focused on building nurse skills and confidence for PIV insertion was highlighted and organizations should continue to direct efforts toward developing skills and competency for staff that

  19. The risk of bloodstream infection associated with peripherally inserted central catheters compared with central venous catheters in adults: a systematic review and meta-analysis.

    Science.gov (United States)

    Chopra, Vineet; O'Horo, John C; Rogers, Mary A M; Maki, Dennis G; Safdar, Nasia

    2013-09-01

    Peripherally inserted central catheters (PICCs) are associated with central line-associated bloodstream infection (CLABSI). The magnitude of this risk relative to central venous catheters (CVCs) is unknown. To compare risk of CLABSI between PICCs and CVCs. MEDLINE, CinAHL, Scopus, EmBASE, and Cochrane CENTRAL were searched. Full-text studies comparing the risk of CLABSI between PICCs and CVCs were included. Studies involving adults 18 years of age or older who underwent insertion of a PICC or a CVC and reported CLABSI were included in our analysis. Studies were evaluated using the Downs and Black scale for risk of bias. Random effects meta-analyses were used to generate summary estimates of CLABSI risk in patients with PICCs versus CVCs. Of 1,185 studies identified, 23 studies involving 57,250 patients met eligibility criteria. Twenty of 23 eligible studies reported the total number of CLABSI episodes in patients with PICCs and CVCs. Pooled meta-analyses of these studies revealed that PICCs were associated with a lower risk of CLABSI than were CVCs (relative risk [RR], 0.62; 95% confidence interval [CI], 0.40-0.94). Statistical heterogeneity prompted subgroup analysis, which demonstrated that CLABSI reduction was greatest in outpatients (RR [95% CI], 0.22 [0.18-0.27]) compared with hospitalized patients who received PICCs (RR [95% CI], 0.73 [0.54-0.98]). Thirteen of the included 23 studies reported CLABSI per catheter-day. Within these studies, PICC-related CLABSI occurred as frequently as CLABSI from CVCs (incidence rate ratio [95% CI], 0.91 [0.46-1.79]). Only 1 randomized trial met inclusion criteria. CLABSI definition and infection prevention strategies were variably reported. Few studies reported infections by catheter-days. Although PICCs are associated with a lower risk of CLABSI than CVCs in outpatients, hospitalized patients may be just as likely to experience CLABSI with PICCs as with CVCs. Consideration of risks and benefits before PICC use in inpatient

  20. Tunnel unroofing effectiveness in chronic peritoneal catheter infection

    Directory of Open Access Journals (Sweden)

    Lorena Carranza

    2017-04-01

    Full Text Available Introduction: Chronic catheter infection usually involves external Dacron cuff colonization, without its removal, antibiotic treatment proved ineffective. Catheter unroofing technique has been described as an alternative to peritoneal catheter removal. Material and methods: We analyzed the data from 13 patients retrospectively. Evolution after unroofing was evaluated, considering as treatment failure the appearance of new infection in the hole, tunnel or peritonitis associated to the same germ. Results: Between 1997-2014 years, unroofing was performed on 13 patients. Mean age-rate: 46.2 (IC 95%: 35.9 years – 56.5 years male sex 9, 69.23%. Germs: staphylococcus 7, pseudomona 2, polymicrobial 1, negative culture 3. Nine patiens healed: 69.2%; there was no statistical association among sex, age, microbiological result, previous hemodialysis use, type of catheter, surgical technique or with the surgeon who performed the procedure (p≥ 0.05. Discussion: Catheter removal implies transient transference to hemodialysis and new replacement surgery, although there is few experience with this technique, it could be an acceptable alternative, enabling a group of patients to continue with PD treatment. Conclusion: Unroofing technique proved to be beneficial in 69.2% of the cases (9 patients independently of the type of germ present, representing an acceptable treatment which avoids catheter removal, enabling the procedure to continue, and decreasing the need to employ more aggressive therapies.

  1. Iatrogenic Bowel Injury at Exchange of Supra-Pubic Catheter

    LENUS (Irish Health Repository)

    Foran, AT

    2018-04-01

    Suprapubic catheter insertion and exchange is a common urological procedure, but it is not without risks and complications. While bowel perforation is a recognised complication at suprapubic catheter insertion, it is not commonly reported at suprapubic catheter exchange. We report our experience of recognition, diagnosis and subsequent successful management of the most important complication related to suprapubic catheters.

  2. Evaluation of the conformity of assistential practice in the maintenance of the temporary double-lumen dialysis catheter.

    Science.gov (United States)

    Rosetti, Késia Alves Gomes; Tronchin, Daisy Maria Rizatto

    2014-01-01

    to evaluate the conformity of the assistential practice in the maintenance of the temporary double-lumen catheter for hemodialysis, by means of the use of the process indicator, in the University Hospital of the University of São Paulo. a quantitative, exploratory-descriptive and observational study. The sample was made up of 155 observations of persons with temporary double-lumen catheters, in the period March-November 2011, using the Indicator of the Maintenance of the Temporary Double Lumen Catheter for Hemodialysis. the rate of general conformity of the assistential practice corresponded to 65.8%. Of the practice's 13 components, 9 (69.2%) attained 100% conformity. The hygienization of hands by the professionals and the use of a mask by the patients during the disconnection from the hemodialysis had the worst rates (83.9%). although the actions evaluated are implemented in the unit, it is necessary to propose and apply educational strategies with the health team, as well as to institute periodical assessments, so as to raise the conformity rates, ensuring the quality of the hemodialysis services.

  3. STUDY OF CENTRAL VENOUS CATHETER RELATED BLOOD STREAM INFECTIONS IN PATIENTS ON HAEMODIALYSIS

    Directory of Open Access Journals (Sweden)

    Pranjal Pankaj

    2018-01-01

    Full Text Available BACKGROUND Temporary and permanent central venous catheters are used in majority of patients of CKD when initiated on hemodialysis and mostly these catheters act as bridge before permanent AV fistula assess could be obtained. Blood stream infections related to these central venous catheters are an important cause of morbidity and mortality in these patients. Appropriate antiseptic precautions while inserting central venous catheter and early identification of catheter related blood stream infections (CRBSI are of utmost importance for reducing hospital stay, cost of therapy and mortality. MATERIALS AND METHODS A total of 50 patients of CKD were included in the study who had central venous catheter in situ (internal jugular or subclavian and developed symptoms related to blood stream infections. Blood cultures were obtained from the catheter lumen and a separate venous site 1 hour apart. All the culture sensitivity reports were obtained from department of microbiology of our institute. Inclusion Criteria- Known case of CKD patients aged more than 18yrs on hemodialysis with symptoms and signs of catheter related blood stream infections were included in the study. Exclusion Criteria- Patients with other associated comorbid infections like Koch’s, urinary tract infection or others mimicking symptoms of CRBSI. RESULTS The cultures were found positive in 38 patients (76% while in rest 24% cases positive cultures could not be obtained. Out of culture positive patients 52.63% cases were found to have gram positive infections while 44.74% had gram negative infections. In 2.63% patients, fungus was isolated to be the causative organism. Among the gram positive organisms 50% had CoNS, 30% had MSSA and 20% had MRSA infections. Among the gram negative group, 47.06% had klebsiella, 23.53% had acinetobacter, 17.65% had E.coli and 11.76% had pseudomonas as the causative organisms. Mortality was observed in 14% patients out of which 28.57% were culture

  4. Vascular access complications and risk factors in hemodialysis ...

    African Journals Online (AJOL)

    Tarek A. Ghonemy

    2015-08-18

    Aug 18, 2015 ... BMI were significant in patients with central blood infection (p < 0.008, <0.008 and <0.001 ... grafts) for hemodialysis over using the venous catheter as they ... were subjected to the following: thorough full history taking.

  5. Computer Identification of Symptomatic Deep Venous Thrombosis Associated with Peripherally Inserted Central Catheters

    Science.gov (United States)

    Evans, R. Scott; Linford, Lorraine H.; Sharp, Jamie H.; White, Gayle; Lloyd, James F.; Weaver, Lindell K.

    2007-01-01

    Peripherally inserted central catheters (PICCs) are considered a safe method to provide long-term antibiotic therapy, chemotherapy and nutrition support. Deep venous thrombosis (DVT) is a complication that requires early PICC removal, may extend hospitalization and can result in pulmonary embolism. PICC insertion teams strive to understand risk factors and develop methods to prevent DVTs. However, they can only manage what they can measure. At LDS Hospital, identification of PICC associated DVTs was dependent on verbal notification or manual surveillance of more than a thousand free-text vascular reports. Accurate DVT rates were not known which hindered prevention. We describe the development of a computer application (PICC-DVT monitor) to identify PICC associated DVTs each day. A one-year evaluation of the monitor by the PICC team and a review of 445 random vascular reports found a positive predictive value of 98%, sensitivity of 94%, specificity of 100% and a PICC team associated DVT rate of 2.8%. PMID:18693831

  6. Computer identification of symptomatic deep venous thrombosis associated with peripherally inserted venous catheters.

    Science.gov (United States)

    Evans, R Scott; Linford, Lorraine H; Sharp, Jamie H; White, Gayle; Lloyd, James F; Weaver, Lindell K

    2007-10-11

    Peripherally inserted central catheters (PICCs) are considered a safe method to provide long-term antibiotic therapy, chemotherapy and nutrition support. Deep venous thrombosis (DVT) is a complication that requires early PICC removal, may extend hospitalization and can result in pulmonary embolism. PICC insertion teams strive to understand risk factors and develop methods to prevent DVTs. However, they can only manage what they can measure. At LDS Hospital, identification of PICC associated DVTs was dependent on verbal notification or manual surveillance of more than a thousand free-text vascular reports. Accurate DVT rates were not known which hindered prevention. We describe the development of a computer application (PICC-DVT monitor) to identify PICC associated DVTs each day. A one-year evaluation of the monitor by the PICC team and a review of 445 random vascular reports found a positive predictive value of 98%, sensitivity of 94%, specificity of 100% and a PICC team associated DVT rate of 2.8%.

  7. Cost analysis of the Hemodialysis Reliable Outflow (HeRO) Graft compared to the tunneled dialysis catheter.

    Science.gov (United States)

    Al Shakarchi, Julien; Inston, Nicholas; Jones, Robert G; Maclaine, Grant; Hollinworth, David

    2016-04-01

    In end-stage renal disease patients with central venous obstruction, who have limited vascular access options, the Hemodialysis Reliable Outflow (HeRO) Graft is a new alternative with a lower incidence of complications and longer effective device life compared to tunneled dialysis catheters (TDCs). We undertook an economic analysis of introducing the HeRO Graft in the UK. A 1-year cost-consequence decision analytic model was developed comparing management with the HeRO Graft to TDCs from the perspective of the National Health Service in England. The model comprises four 3-month cycles during which the vascular access option either remains functional for hemodialysis or fails, patients can experience access-related infection and device thrombosis, and they can also accrue associated costs. Clinical input data were sourced from published studies and unit cost data from National Health Service 2014-15 Reference Costs. In the base case, a 100-patient cohort managed with the HeRO Graft experienced 6 fewer failed devices, 53 fewer access-related infections, and 67 fewer device thromboses compared to patients managed with TDCs. Although the initial device and placement costs for the HeRO Graft are greater than those for TDCs, savings from the lower incidence of device complications and longer effective device patency reduces these costs. Overall net annual costs are £2600 for each HeRO Graft-managed patient compared to TDC-managed patients. If the National Health Service were to reimburse hemodialysis at a uniform rate regardless of the type of vascular access, net 1-year savings of £1200 per patient are estimated for individuals managed with the HeRO Graft. The base case results showed a marginal net positive cost associated with vascular access with the HeRO Graft compared with TDCs for the incremental clinical benefit of reductions in patency failures, device-related thrombosis, and access-related infection events in a patient population with limited options for

  8. Catheter-related bloodstream infection.

    Science.gov (United States)

    Goede, Matthew R; Coopersmith, Craig M

    2009-04-01

    Catheter-related bloodstream infections (CR-BSIs) are a common, frequently preventable complication of central venous catheterization. CR-BSIs can be prevented by strict attention to insertion and maintenance of central venous catheters and removing unneeded catheters as soon as possible. Antiseptic- or antibiotic-impregnated catheters are also an effective tool to prevent infections. The diagnosis of CR-BSI is made largely based on culture results. CR-BSIs should always be treated with antibiotics, and except in rare circumstances the infected catheter needs to be removed.

  9. Suction catheter guided insertion of ProSeal laryngeal mask airway: Experience by untrained physicians

    Directory of Open Access Journals (Sweden)

    Valter Perilli

    2014-01-01

    Full Text Available Background: The use of suction catheter (SC has been shown to improve success rate during ProSeal laryngeal mask airway (PLMA insertion in expert users. Aims: The aim of this study was to compare insertion of PLMA performed by untrained physicians using a SC or the digital technique (DT in anaesthetised non-paralysed patients. Methods: In this prospective randomised double-blind study, conducted in the operating setting, 254 patients (American Society of Anaesthesiologists I-II, aged 18-65 years, undergoing minor surgery were enrolled. Exclusion criteria were body mass index >35 kg/m 2 , laryngeal or oesophageal varices, risk of aspiration or difficult face mask ventilation either referred or suspected (Langeron′s criteria ≥2 and modified Mallampati classification score >2. Participants were randomly allocated to one of the two groups in which PLMA was inserted using DT (DT-group or SC (SC-group. Statistical Analysis: Chi-square test with Yates′ correction, Mann-Whitney U-test or Student′s t-test were carried-out as appropriate. Results: The final insertion success rate was greater in SC-groupcompared with DT-group 90.1% (n = 109 versus 74.4% (n = 99 respectively (P = 0.002. Mean airway leak pressure was higher in SC-group compared to DT-group (23.7 ± 3.9 vs. 21.4 ± 3.2 respectively; (P = 0.001. There were no differences in insertion time, post-operative airway morbidity and complications. Conclusion: The findings of this study suggest that SC-technique improves the success rate of PLMA insertion by untrained physicians.

  10. Percutaneous transfemoral repositioning of malpositioned central venous catheters.

    Science.gov (United States)

    Hartnell, G G; Roizental, M

    1995-04-01

    Central venous catheters inserted by blind surgical placement may not advance into a satisfactory position and may require repositioning. Malpositioning via surgical insertion is common in patients in whom central venous catheters have previously been placed, as these patients are more likely to have central venous thrombosis and distortion of central venous anatomy. This is less of a problem when catheter placement is guided by imaging; however, even when insertion is satisfactory, central venous catheters may become displaced spontaneously after insertion (Fig. 1). Repositioning can be effected by direct manipulation using guidewires or tip-deflecting wires [1, 2], by manipulation via a transfemoral venous approach [3-5], and by injection of contrast material or saline [6]. Limitations of the direct approach include (1) the number and type of maneuvers that can be performed to effect repositioning when anatomy is distorted, (2) difficulty in accessing the catheter, and (3) the risk of introducing infection. Moreover, these patients are often immunosuppressed, and there is a risk of introducing infection by exposing and directly manipulating the venous catheter. Vigorous injection of contrast material or saline may be unsuccessful for the same reasons: It seldom exerts sufficient force to reposition large-caliber central venous catheters and may cause vessel damage or rupture if injection is made into a small or thrombosed vessel. We illustrate several alternative methods for catheter repositioning via a transfemoral venous approach.

  11. Peripherally Inserted Central Catheters in Pediatric Patients: To Repair or Not Repair

    International Nuclear Information System (INIS)

    Gnannt, Ralph; Patel, Premal; Temple, Michael; Al Brashdi, Yahya; Amaral, Joao; Parra, Dimitri; Rea, Vanessa; Stephens, Derek; Connolly, Bairbre

    2017-01-01

    IntroductionPreservation of venous access in children is a major concern in pediatric interventional radiology. If a peripherally inserted central catheter (PICC) breaks, there are two options: repair the line with a repair kit or exchange the line over a wire in the interventional suite. The purpose of this study is to assess the outcome of PICC repairs in children and to compare these with the outcomes of PICC exchange.Materials and MethodsThis is a single-center, retrospective study of central line-associated bloodstream infection (CLABSI) following management of externally broken PICCs (2010–2014). The occurrence of CLABSI within 30 days after repair (Group A) or exchange (Group B) of a line was analyzed, as well as PICCs exchanged following an initial and failed repair.ResultsA total of 235 PICC breaks were included in the study, of which 161 were repaired, and 116 of whom were successful (68%, Group A). No repair was performed in 74 PICCs—55/74 of these were exchanged over a wire (74%, Group B), and 19/74 lines were removed. The 30 days post-repair CLABSI rate (Group A) was 2.0 infections per 1000 catheter days, and the calculated risk was 4.3%. In comparison the 30 days post-exchange CLABSI rate (Group B) was 4.0 per 1000 catheter days and the calculated risk 10.9%. This difference was significant when adjusted for antibiotic use (OR 3.87; 95% CI 1.07–14.0, p = 0.039).ConclusionThe results of this study support repairing a broken PICC instead of removing or replacing the line.

  12. Peripherally Inserted Central Catheters in Pediatric Patients: To Repair or Not Repair

    Energy Technology Data Exchange (ETDEWEB)

    Gnannt, Ralph, E-mail: ralph.gnannt@usz.ch; Patel, Premal; Temple, Michael; Al Brashdi, Yahya; Amaral, Joao; Parra, Dimitri; Rea, Vanessa [University of Toronto, Image Guided Therapy, Diagnostic Imaging, The Hospital for Sick Children (Canada); Stephens, Derek [University of Toronto, Child Health Evaluative Sciences (Canada); Connolly, Bairbre [University of Toronto, Image Guided Therapy, Diagnostic Imaging, The Hospital for Sick Children (Canada)

    2017-06-15

    IntroductionPreservation of venous access in children is a major concern in pediatric interventional radiology. If a peripherally inserted central catheter (PICC) breaks, there are two options: repair the line with a repair kit or exchange the line over a wire in the interventional suite. The purpose of this study is to assess the outcome of PICC repairs in children and to compare these with the outcomes of PICC exchange.Materials and MethodsThis is a single-center, retrospective study of central line-associated bloodstream infection (CLABSI) following management of externally broken PICCs (2010–2014). The occurrence of CLABSI within 30 days after repair (Group A) or exchange (Group B) of a line was analyzed, as well as PICCs exchanged following an initial and failed repair.ResultsA total of 235 PICC breaks were included in the study, of which 161 were repaired, and 116 of whom were successful (68%, Group A). No repair was performed in 74 PICCs—55/74 of these were exchanged over a wire (74%, Group B), and 19/74 lines were removed. The 30 days post-repair CLABSI rate (Group A) was 2.0 infections per 1000 catheter days, and the calculated risk was 4.3%. In comparison the 30 days post-exchange CLABSI rate (Group B) was 4.0 per 1000 catheter days and the calculated risk 10.9%. This difference was significant when adjusted for antibiotic use (OR 3.87; 95% CI 1.07–14.0, p = 0.039).ConclusionThe results of this study support repairing a broken PICC instead of removing or replacing the line.

  13. Endovascular Revascularization of Hemodialysis Thrombosed Grafts with the Hydrodynamic Thrombectomy Catheter. Our 7-Year Experience

    Energy Technology Data Exchange (ETDEWEB)

    Bermudez, Patrícia, E-mail: pbermude@clinic.ub.es [Clinic Hospital of Barcelona, Vascular and Interventional Radiology Unit, Diagnostic Imaging Institute (Spain); Fontseré, Nestor, E-mail: fontsere@clinic.ub.es [Clinic Hospital of Barcelona, Vascular Access Unit, Nephrologic and Urologic Diseases Clinical Institute (Spain); Mestres, Gaspar, E-mail: gmestres@clinic.ub.es [Clinic Hospital of Barcelona, Cardiovascular Diseases Institute (Spain); García-Gámez, Andres, E-mail: garciagam@clinic.ub.es; Barrufet, Marta, E-mail: barrufet@clinic.ub.es; Burrel, Marta, E-mail: mburrel@clinic.ub.es; Gilabert, Rosa, E-mail: gilabert@clinic.ub.es; Gómez, Fernando, E-mail: fegomez@clinic.ub.es; Macho, Juan, E-mail: jmmacho@clinic.ub.es [Clinic Hospital of Barcelona, Vascular and Interventional Radiology Unit, Diagnostic Imaging Institute (Spain)

    2017-02-15

    PurposeTo evaluate the efficacy and safety of the hydrodynamic thrombectomy catheter (AngioJet DVX) in the salvage of thrombosed hemodialysis vascular grafts.Materials and MethodsA retrospective study was designed, including all patients with occluded arteriovenous grafts treated with the AngioJet system between 2007 and 2014 in our institution. Outcomes included technical success, clinical success, complications, and primary and secondary patencies. Procedural success was defined as angiographic confirmation of flow restoration, the presence of a pulsatile thrill along the graft, and successful resumption of at least one hemodialysis session. Primary and secondary patencies after first AVG thrombectomy were calculated with Kaplan–Meier curves. Cox regression was used to determine prognostic factors of primary patency after every thrombectomy episode.ResultsA total of 149 thrombectomies were performed in 68 grafts. After thrombectomy, endovascular treatment of one or more stenosis was performed in all cases. Technical success was 93% and clinical success was 86%. Complications occurred in 7 thrombectomies, most of them were minor except for one anastomosis rupture requiring surgery. Primary and secondary patencies were 52, 41, and 23 and 76, 68, and 57% at 3, 6 and 12 months, respectively. Independent prognostic factors of poor patency after every thrombectomy episode were the presence of residual thrombus (OR 1.831, P = 0.008) and time from last thrombosis (less than 1 month; and OR 7.116, P < 0.001).ConclusionPercutaneous mechanical thrombectomy with AngioJet is a safe technique with a high-clinical success rate. The presence of residual thrombus after thrombectomy and early re-occlusions are related to poorer results.

  14. Intracorporeal knotting of a femoral nerve catheter

    Directory of Open Access Journals (Sweden)

    Ghanem, Mohamed

    2015-01-01

    Full Text Available Peripheral nerve catheters are effective and well-established tools to provide postoperative analgesia to patients undergoing orthopedic surgery. The performance of these techniques is usually considered safe. However, placement of nerve catheters may be associated with a considerable number of side effects and major complications have repeatedly been published. In this work, we report on a patient who underwent total knee replacement with spinal anesthesia and preoperative insertion of femoral and sciatic nerve catheters for postoperative analgesia. During insertion of the femoral catheter, significant resistance was encountered upon retracting the catheter. This occurred due to knotting of the catheter. The catheter had to be removed by operative intervention which has to be considered a major complication. The postoperative course was uneventful. The principles for removal of entrapped peripheral catheters are not well established, may differ from those for neuroaxial catheters, and range from cautious manipulation up to surgical intervention.

  15. A Simulation-Based Blended Curriculum for Short Peripheral Intravenous Catheter Insertion: An Industry-Practice Collaboration.

    Science.gov (United States)

    Glover, Kevin R; Stahl, Brian R; Murray, Connie; LeClair, Matthew; Gallucci, Susan; King, Mary Anne; Labrozzi, Laura J; Schuster, Catherine; Keleekai, Nowai L

    2017-09-01

    Despite peripheral intravenous catheter (PIVC) insertion being a commonly performed skill, practicing nurses may receive little substantive education, training, or opportunities to practice this skill at a competent level. This article describes a collaboration between private industry and a hospital to modify, implement, and evaluate a simulation-based blended PIVC insertion continuing education program for staff nurses. Included is an overview of the practical and theoretical rationale for the initial development of the curriculum to address an identified PIVC insertion education gap, the collaborative modification and implementation of the program, and an evaluation of the program. The curriculum combined self-paced e-learning and classroom-based deliberate practice with simulation tools of varying fidelity in a peer-to-peer learning environment. Given the mutual challenges of resource allocation in industry training and clinical nursing education departments, interprofessional partnerships may be an effective option for sharing instructional knowledge and resources to promote innovation and improve patient care. J Contin Educ Nurs. 2017;48(9):397-406. Copyright 2017, SLACK Incorporated.

  16. Greece reports prototype intervention with first peripherally inserted central catheter: case report and literature review.

    Science.gov (United States)

    Konstantinou, Evangelos A; Stafylarakis, Emmanuil; Kapritsou, Maria; Mitsos, Aristotelis P; Fotis, Theofanis G; Kiekkas, Panagiotis; Mariolis-Sapsakos, Theodoros; Argyras, Eriphyli; Nomikou, Irini Th; Dimitrakopoulos, Antonios

    2012-09-01

    Placement of peripherally inserted central catheters (PICCs), definitely offers a clear advantage over any other method regarding central venous catheterization. Its ultrasonographic orientation enhances significantly its accuracy, safety and efficacy, making this method extremely comfortable for the patient who can continue his or her therapy even in an outpatient basis. We present the first reported case of a PICCS insertion in Greece, which has been performed by a university-degree nurse. The aim of this review of literature was to present the evolution in nursing practice in Greece. A PICC was inserted in a 77-year-old male patient suffering from a recent chemical pneumonia with a history of Alzheimer's disease. A description of all the technical details of this insertion is reported, focusing on the pros and cons of the method and a thorough review of the history and advances in central venous catheterization throughout the years is also presented. PICCs provide long-term intravenous access and facilitate the delivery of extended antibiotic therapy, chemotherapy and total parenteral nutrition. We strongly believe that PICCs are the safest and most effective method of peripherally inserted central venous catheterization. Larger series are necessary to prove the above hypothesis, and they are under construction by our team. Copyright © 2012 Society for Vascular Nursing, Inc. Published by Mosby, Inc. All rights reserved.

  17. Delayed Migration and Perforation of the Jugular Vein by a Peripherally Inserted Central Catheter

    Directory of Open Access Journals (Sweden)

    Joshua J. Oliver

    2017-10-01

    Full Text Available We report a case of peripherally inserted central catheter (PICC migration and perforation of the left internal jugular vein in a home health setting in an 80-year-old female. A left sided PICC was placed for treatment of diverticulitis following hospital discharge. She complained of sudden onset left sided neck pain immediately after starting an infusion of vancomycin. In the emergency department the injury was identified by portable chest radiograph and computed tomography of her neck. Following removal of the line, she had an uneventful course. Emergency physicians should be aware of this possible PICC line complication.

  18. PTFE grafts versus tunneled cuffed catheters for hemodialysis: which is the second choice when arteriovenous fistula is not feasible?

    Science.gov (United States)

    Donati, Gabriele; Cianciolo, Giuseppe; Mauro, Raffaella; Rucci, Paola; Scrivo, Anna; Marchetti, Antonio; Giampalma, Emanuela; Golfieri, Rita; Panicali, Laura; Iorio, Mario; Stella, Andrea; La Manna, Gaetano; Stefoni, Sergio

    2015-02-01

    Vascular access-related complications are still one of the leading causes of morbidity in hemodialysis patients. The aim of this study was to compare polytetrafluoroethylene (PTFE) grafts versus tunneled cuffed permanent catheters (TCCs) in terms of vascular access and patients' survival. An observational study was carried out with a 2-year follow-up. Eighty-seven chronic hemodialysis patients were enrolled: 31 with a PTFE graft as vascular access for hemodialysis versus 56 with a TCC. Patients' mean age was 63.8 ± 14.6 (grafts) versus 73.5 ± 11.3 years (TCCs), P = 0.001. Significantly more patients with TCC had atrial fibrillation than patients with grafts (30.3% versus 6.5%, P = 0.01). In an unadjusted Kaplan-Meier analysis, median TCC survival at 24 months was 5.4 months longer than that of PTFE grafts but not significantly (log-rank test = 1.3, P = ns). In a Cox regression analysis adjusted for age, gender, number of previous vascular accesses, diabetes, atrial fibrillation, smoking, and any complication, this lack of significant difference in survival of the vascular access between TCC and PTFE groups was confirmed and diabetes proved to be an independent risk factor for the survival of both vascular accesses considered (P = 0.02). In an unadjusted Kaplan-Meier analysis, a higher mortality was found in the TCC group than in the PTFE group at 24 months (log-rank test = 10.07, P PTFE grafts. When an arteriovenous fistula (AVF) is not possible, PTFE grafts can be considered the vascular access of second choice, whereas TCCs can be used when an AVF or PTFE graft are not feasible or as a bridge to AVF or PTFE graft creation. Copyright © 2014 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  19. Central venous catheters: the role of radiology

    International Nuclear Information System (INIS)

    Tan, P.L.; Gibson, M.

    2006-01-01

    The insertion and management of long-term venous catheters have long been the province of anaesthetists, intensive care physicians and surgeons. Radiologists are taking an increasing role in the insertion of central venous catheters (CVCs) because of their familiarity with the imaging equipment and their ability to manipulate catheters and guide-wires. The radiological management of the complications of CVCs has also expanded as a result. This article reviews the role of radiology in central venous access, covering the detection and management of their complications

  20. Catheter Displacement into Inferior Epigastric Vein Causing Local Phlebitis and Cellulitis

    Directory of Open Access Journals (Sweden)

    Noriko Hattori

    2012-01-01

    Full Text Available Catheter insertion for intravenous hyperalimentation is a commonly and widely used clinical technique. When compared with the incidence of complications associated with insertions into the internal jugular vein or the subclavian vein, complications associated with insertions into the femoral vein are less frequent. In this paper, we describe a very rare complication of femoral vein catheter insertion—namely, catheter displacement into the inferior epigastric vein.

  1. Analysis of risk factors and the establishment of a risk model for peripherally inserted central catheter thrombosis

    OpenAIRE

    Fang Hu; Ruo-Nan Hao; Jie Zhang; Zhi-Cheng Ma

    2016-01-01

    Objective: To investigate the main risk factors of peripherally inserted central catheter (PICC) related upper extremity deep venous thrombosis and establish the risk predictive model of PICC-related upper extremity deep venous thrombosis. Methods: Patients with PICC who were hospitalized between January 2014 and July 2015 were studied retrospectively; they were divided into a thrombosis group (n = 52), with patients who had a venous thrombosis complication after PICC, and a no-thrombosis ...

  2. Adjusting the displaced tip of peripherally inserted central catheter under DSA guidance

    International Nuclear Information System (INIS)

    Mao Yanjun; Dong Huijuan; Zhang Lingjuan; Li Hongmei; Xu Lianqin

    2009-01-01

    Objective: To explore a new method to adjust the displaced tip of peripherally inserted central catheter (PICC) under DSA guidance. Methods: Under DSA guidance, the displaced tip of PICC was repositioned to the ideal junction area of superior vena cava with right atrium with proper manipulation. Results: Under DSA guidance, the displaced tip of PICC was successfully corrected in 13 cases. The mean operative time was 15.53 minutes, which was markedly shorter than that needed by blind adjusting beside the bed. Conclusion: The displacement of PICC tip is a common occurrence, which is hard to be avoided. Under DSA guidance, the adjusting manipulation of the displaced PICC tip is safe and time-saving with high successful rate. It is worth popularizing this technique in clinical practice. (authors)

  3. Dialysis catheter-related septicaemia--focus on Staphylococcus aureus septicaemia

    DEFF Research Database (Denmark)

    Nielsen, J; Ladefoged, S D; Kolmos, H J

    1998-01-01

    BACKGROUND: Dialysis catheters are a common cause of nosocomial septicaemia in haemodialysis units usually due to staphylococci, of which Staphylococcus aureus is the most pathogenic. In this study, the epidemiology and pathogenesis of dialysis catheter-related infections were studied, and methods...... to infection were measured. After catheter insertion, all patients were screened for nasal carriage of S. aureus, and a culture was taken from the skin overlying the catheter insertion site. Once a week, cultures were taken from the insertion site and from the hub, and aerobic and anaerobic blood cultures were...... drawn from the catheter. If clinical signs of septicaemia occurred, peripheral blood cultures were also performed, when it was possible. RESULTS: The incidence of septicaemia was 49% (21/43) in patients, and 56% of all cases were caused by S. aureus. The mortality was 14% (3/21) and the incidence...

  4. Epidural Catheter Breakage In-Situ

    Directory of Open Access Journals (Sweden)

    Geetanjali S Verma

    2014-09-01

    Full Text Available A 45yr old woman diagnosed with dysfunctional uterine bleeding and incisional hernia was planned for total abdominal hysterectomy with bilateral salpingo-oophorectomy and mesh repair under combined spinal and epidural anaesthesia. Using VYGON® epidural catheter with its recommended introducer, the catheter was inserted but it snapped off at 11cm mark while positioning the catheter. After radiological confirmation, the neurosurgeon removed the catheter under general anaesthesia, which was followed by the scheduled surgery.

  5. Efficacy of Prophylactic Antibiotics at Peritoneal Catheter Insertion on Early Peritonitis: Data from the Catheter Section of the French Language Peritoneal Dialysis Registry.

    Science.gov (United States)

    Lanot, Antoine; Lobbedez, Thierry; Bechade, Clémence; Verger, Christian; Fabre, Emmanuel; Dratwa, Max; Vernier, Isabelle

    2016-01-01

    International guidelines recommend the use of a prophylactic antibiotic before the peritoneal dialysis (PD) catheter can be inserted. The main objective of this study was to assess whether this practice is associated with a lower risk of early peritonitis and to estimate the magnitude of the centre effect. A retrospective, multi-centric study was conducted, in which data from the French Language Peritoneal Dialysis Registry was analysed. Patients were separated into 2 groups based on whether or not prophylactic antibiotics were used prior to catheter placement. Out of the 2,014 patients who had a PD catheter placed between February 1, 2012 and December 31, 2014, 1,105 were given a prophylactic antibiotic. In a classical logit model, the use of prophylactic antibiotics was found to protect the individual against the risk of early peritonitis (OR 0.67, 95% CI 0.49-0.92). However, this association lost significance in a mixed logistic regression model with centre as a random effect: OR 0.73 (95% CI 0.48-1.09). Covariates associated with the risk of developing early peritonitis were age over 65: OR 0.73 (95% CI 0.39-0.85), body mass index over 35 kg/m2: OR 1.99 (95% CI 1.13-3.47), transfer to PD due to graft failure: OR 2.24 (95% CI 1.22-4.11), assisted PD: OR 1.96 (95% CI 1.31-2.93), and the use of the Moncrief technique: OR 3.07 (95% CI 1.85-5.11). There is a beneficial effect of prophylactic antibiotic used prior to peritoneal catheter placement, on the occurence of early peritonitis. However, the beneficial effect could be masked by a centre effect. © 2016 S. Karger AG, Basel.

  6. Outcome of tunneled infusion catheters inserted via the right internal jugular vein

    International Nuclear Information System (INIS)

    Shin, Sung Wook; Do, Young Soo; Choo, Sung Wook; Yoo, Wi Kang; Choo, In Wook; Kim, Jae Hyung

    2003-01-01

    To assess the outcome of tunneled central venous catheter placement via the right internal jugular vein. Between June 2001 and May 2002, 670 consecutive Hickman catheters were placed in 654 patients via the right internal jugular vein. The procedural complications arising and follow-up data obtained from May to July 2002 were evaluated. The technical success rate for catheter placement was 99.9% (669/670). Procedural complications were limited to eight cases (1.2%), including three pneumothoraces, one early migration of the catheter, one clinically unimportant air embolism, one catheter injury, one catheter kinking and one primary malpositioning in the azygos vein. Catheter dwelling time ranged from 1 to 407 (mean 107.1) days. During the follow-up period, 416 catheter were removed for various reasons: treatment had ended (n=334), patients declined treatment or their drug regimen was changed (n=16), late complications arose (n=53), or other circumstances intervened (n=13). Late complications included 44 cases of catheter-related infection (6.6%), five of catheter migration (0.7%), two of catheter occlusion (0.3%), one of thrombophlebitis (0.15%), and one of catheter-related right atrial thrombosis (0.15%). Only one instance of symptomatic venous thrombosis or stenosis was noted, namely the one case of thrombophlebitis. Because the incidence of subsequent symptomatic venous thrombosis or stenosis is lower, the preferred route for tunneled central venous catheter placement is the right internal jugular vein

  7. Randomized Controlled Trial Comparing Open Versus Laparoscopic Placement of a Peritoneal Dialysis Catheter and Outcomes: The CAPD I Trial.

    Science.gov (United States)

    van Laanen, Jorinde H H; Cornelis, Tom; Mees, Barend M; Litjens, Elisabeth J; van Loon, Magda M; Tordoir, Jan H M; Peppelenbosch, Arnoud G

    2018-01-01

    To determine the best operation technique, open versus laparoscopic, for insertion of a peritoneal dialysis (PD) catheter with regard to clinical success. Clinical success was defined as an adequate function of the catheter 2 - 4 weeks after insertion. All patients with end-stage renal disease who were suitable for PD and gave informed consent were randomized for either open surgery or laparoscopic surgery. A previous laparotomy was not considered an exclusion criterion. Laparoscopic placement had the advantage of pre-peritoneal tunneling, the possibility for adhesiolysis, and placement of the catheter under direct vision. Catheter fixation techniques, omentopexy, or other adjunct procedures were not performed. Other measured parameters were in-hospital morbidity and mortality and post-operative infections. Between 2010 and 2016, 95 patients were randomized to this study protocol. After exclusion of 5 patients for various reasons, 44 patients received an open procedure and 46 patients a laparoscopic procedure. Gender, age, body mass index (BMI), hypertension, current hemodialysis, severe heart failure, and previous an abdominal operation were not significantly different between the groups. However, in the open surgery group, fewer patients had a previous median laparotomy compared with the laparoscopic group (6 vs 16 patients; p = 0.027). There was no statistically significant difference in mean operation time (36 ± 24 vs 38 ± 15 minutes) and hospital stay (2.1 ± 2.7 vs 3.1 ± 7.3 days) between the groups. In the open surgery group 77% of the patients had an adequate functioning catheter 2 - 4 weeks after insertion compared with 70% of patients in the laparoscopic group ( p = not significant [NS]). In the open surgery group there was 1 post-operative death (2%) compared with none in the laparoscopic group ( p = NS). The morbidity in both groups was low and not significantly different. In the open surgery group, 2 patients had an exit-site infection and 1 patient

  8. An Evaluation of Complications in Ultrasound-Guided Central Venous Catheter Insertion in the Emergency Department

    Directory of Open Access Journals (Sweden)

    Engin OZAKIN

    2014-06-01

    Full Text Available SUMMARY: Objectives: In emergency departments, emergency physicians frequently have to perform central venous access. In cases where peripheral venous access is not possible, central venous access is required for dialysis, fulfillment of urgent fluid need, or central venous pressure measurement. This study was carried out to evaluate the emergence of complications in the process of and in the 15 days following the insertion of central venous catheter under ultrasound guidance in the emergency department. Methods: For this study, patients who presented to the emergency department over a period of eight months with an urgent need for central catheter were examined prospectively. Age, gender, and accompanying diseases of patients as well as the type, time, duration, and indication of the venous access were recorded. Furthermore, the amount of experience of the physician was taken into consideration. Results: In the emergency department, physicians performed ultrasound-guided central venous catheter insertion for 74 patients (40 men and 34 women. For access, internal jugular vein was used in 65 (87.8% patients, and femoral vein was used in 9 (12.2% patients. The reason for access was urgent dialysis need in 55 (74.3%, CVP measurement in 3 (4.1%, fluid support due to severe hypovolemia in 6 (8.1%, and difficulty of peripheral venous access in 10 (13.5% patients. None of the patients developed complications in the process of or after the insertion. Patients did not have infections related to the catheter in 15 days following the insertion. Conclusions: Central venous access is frequently required in emergency departments. The risk of complication is little if any in ultrasonographyguided access carried out under appropriate conditions. ÖZET: Amaç: Acil servislerde acil tıp hekimlerince santral damar yolu işlemi sık uygulanır. Periferik damar yolu açılamadığı hallerde, diyaliz, acil sıvı ihtiyacı veya santral venöz basınç

  9. A hospital-acquired outbreak of catheter-related nontuberculous mycobacterial infection in children on peritoneal dialysis

    OpenAIRE

    Yamada, Takuji; Ushijima, Katsumi; Uemura, Osamu

    2014-01-01

    Catheter-related nontuberculous mycobacterial infection in children with chronic renal failure on peritoneal dialysis (PD) is rare. However, there have been five such infections in infants among PD patients at our center. Although the patients were treated with antibiotics to which the organisms showed in vitro sensitivity, they were clinically drug resistant. Hence, all PD catheters needed to be removed. Thereafter, following hemodialysis treatment for approximately 1 month, the PD catheters...

  10. Fluoroscopy guided percutaneous catheter drainage of pneumothorax in good mid-term patency with tube drainage

    International Nuclear Information System (INIS)

    Park, Ga Young; Oh, Joo Hyung; Yoon, Yup; Sung, Dong Wook

    1995-01-01

    To evaluate efficacy and the safety of percutaneous catheter drainage in patients with pneumothorax that is difficult to treat with closed thoracotomy. We retrospectively reviewed effectiveness of percutaneous catheter drainage (PCD) in 10 patients with pneumothorax. The catheter was inserted under fluoroscopic guidance. Seven patients had spontaneous pneumothorax caused by tuberculosis (n =4), reptured bullae (n = 2), and histiocytosis-X (n = 1). Three patients had iatrogenic pneumothorax caused by trauma (n = 1) and surgery (n = 2). All procedures were performed by modified Seldinger's method by using 8F-20F catheter. All catheter were inserted successfully. In 9 of 10 patients, the procedure was curative without further therapy. Duration of catheter insertion ranged from 1 day to 26 days. In the remaining 1 patient in whom multiple pneumothorax occurred after operation, catheter insertion was performed twice. Percutaneous catheter drainage under fluoroscopic guidance is effective and safe procedure for treatment of pneumothorax in patients with failed closed thoracotomy

  11. Fluoroscopy guided percutaneous catheter drainage of pneumothorax in good mid-term patency with tube drainage

    Energy Technology Data Exchange (ETDEWEB)

    Park, Ga Young; Oh, Joo Hyung; Yoon, Yup; Sung, Dong Wook [Kyung Hee University Hospital, Seoul (Korea, Republic of)

    1995-10-15

    To evaluate efficacy and the safety of percutaneous catheter drainage in patients with pneumothorax that is difficult to treat with closed thoracotomy. We retrospectively reviewed effectiveness of percutaneous catheter drainage (PCD) in 10 patients with pneumothorax. The catheter was inserted under fluoroscopic guidance. Seven patients had spontaneous pneumothorax caused by tuberculosis (n =4), reptured bullae (n = 2), and histiocytosis-X (n = 1). Three patients had iatrogenic pneumothorax caused by trauma (n = 1) and surgery (n = 2). All procedures were performed by modified Seldinger's method by using 8F-20F catheter. All catheter were inserted successfully. In 9 of 10 patients, the procedure was curative without further therapy. Duration of catheter insertion ranged from 1 day to 26 days. In the remaining 1 patient in whom multiple pneumothorax occurred after operation, catheter insertion was performed twice. Percutaneous catheter drainage under fluoroscopic guidance is effective and safe procedure for treatment of pneumothorax in patients with failed closed thoracotomy.

  12. The bowed catheter sign: a risk for pericardial tamponade

    Energy Technology Data Exchange (ETDEWEB)

    Towbin, Richard [Phoenix Children' s Hospital, Department of Radiology, Phoenix, AZ (United States)

    2008-03-15

    The use of a central venous catheter (CVC) has become commonplace in the care of children with a wide variety of medical and surgical problems. Complications resulting from the insertion of these catheters are well recognized and can be life-threatening. When a temporary CVC or other catheter is inserted into the central venous system it is secured to the skin with a combination of sutures and sterile dressing. This fixes the catheter in place and does not allow it to retract, thereby putting pressure on the right atrial wall via the catheter tip if it is too long. The probability of wall penetration is increased if a catheter or device is tapered at the point of contact. The purpose of this case report is to present the bowed catheter sign and to review the anatomy of the cavotricuspid isthmus, a possible predisposing factor to cardiac perforation and tamponade. (orig.)

  13. The bowed catheter sign: a risk for pericardial tamponade

    International Nuclear Information System (INIS)

    Towbin, Richard

    2008-01-01

    The use of a central venous catheter (CVC) has become commonplace in the care of children with a wide variety of medical and surgical problems. Complications resulting from the insertion of these catheters are well recognized and can be life-threatening. When a temporary CVC or other catheter is inserted into the central venous system it is secured to the skin with a combination of sutures and sterile dressing. This fixes the catheter in place and does not allow it to retract, thereby putting pressure on the right atrial wall via the catheter tip if it is too long. The probability of wall penetration is increased if a catheter or device is tapered at the point of contact. The purpose of this case report is to present the bowed catheter sign and to review the anatomy of the cavotricuspid isthmus, a possible predisposing factor to cardiac perforation and tamponade. (orig.)

  14. Using an indwelling catheter for the domiciliary management of malignant effusions

    Directory of Open Access Journals (Sweden)

    Ramkumar P

    2003-01-01

    Full Text Available Background: Many patients with malignant pleural effusions and ascites require repeated hospital visits for paracentesis. Materials and Methods: Patients and caregivers were taught to drain malignant effusions at home, using an indwelling catheter inserted into the pleural/ peritoneal cavity. The catheter, (ARROW 14 wire gauge with three additional side holes made to prevent blockage was inserted using the Seldenger technique for central venous cannulation and secured with a stitch. A three way stopcock was used to regulate fluid drainage. The caregiver was taught to do biweekly dressings with antiseptic ointment. Results: The catheter has been used in 200 patients over a period of five years. Two patients developed infections in the pleural cavity, which were managed with antibiotics. Two patients needed catheter change because of blockage. Other patients retained the catheter till last follow up or death. The procedure can be carried out as a day case. This article describes practical guidelines for inserting and maintaining the catheter.

  15. Catheter Associated Urinary Tract Infection Prevention bundle

    Directory of Open Access Journals (Sweden)

    O. Zarkotou

    2017-01-01

    Full Text Available Catheter-associated urinary tract infections (CAUTI are among the most common healthcare-associated infections, and potentially lead to significant morbidity and mortality. Multifaceted infection control strategies implemented as bundles can prevent nosocomial infections associated with invasive devices such as CAUTIs. The components of the CAUTI bundle proposed herein, include appropriate indications for catheterization and recommendations for the procedures of catheter insertion and catheter maintenance and care. Avoiding unnecessary urinary catheter use is the most effective measure for their prevention. To minimize the risk of CAUTI, urinary catheters should be placed only when a clinical valid indication is documented and they should be removed as soon as possible; alternatives to catheterization should also be considered. Aseptic insertion technique, maintenance of closed drainage system and strict adherence to hand hygiene are essential for preventing CAUTI. The successful implementation of the bundle requires education and training for all healthcare professionals and evaluation of surveillance data.

  16. Impact of Peritoneal Dialysis Catheter Insertion by a Nephrologist: Results of a Questionnaire Survey of Patients and Nurses.

    Science.gov (United States)

    Washida, Naoki; Aikawa, Kayoko; Inoue, Shuji; Kasai, Takahiro; Shinozuka, Keisuke; Morimoto, Kohkichi; Hosoya, Kozi; Hayashi, Koichi; Itoh, Hiroshi

    2015-01-01

    Peritoneal dialysis (PD) is an excellent dialysis mo- dality, but it is underutilized in the United States and Japan. In the present study, we evaluated the impact of interventional nephrology in PD on the impres- sions held by patients and nurses about selection of a renal replacement therapy and the complications associated with PD therapy. Over aperiod of 7 years, PD catheter insertion in 120 patients with end-stage renal disease (age: 63.0 ± 13.3 years) was performed by nephrologists at Keio University Hospital or Saitama Medical Center. A questionnaire survey evaluating the advantages and disadvantages of this interventional nephrology approach in PD was distributed to 72 PD patients and to 53 nurses in charge of those patients. After interventional nephrology in PD was adopted, the number of patients selecting PD therapy increased. The incidence of peritonitis was relatively low (1 episode in 101.1 patient-months). Responses to the questionnaire survey showed that neither patients nor nurses were concerned about catheter insertion by physicians, and no communication problems between the patients, nurses, and physicians were reported. Approximately 60% of the nurses specializing in PD therapy showed higher motivation with interventional nephrology, which might have a favorable effect on the selection of PD therapy, on the incidence of peritonitis, and on the tripartite communication between patients, nurses, and physicians.

  17. Laparoscopic Placement of Peritoneal Dialysis Catheters in CAPD Patients: Complications and Survival

    Directory of Open Access Journals (Sweden)

    A Roueentan

    2008-06-01

    Full Text Available Background: Laparoscopic techniques for the placement of peritoneal dialysis catheters are becoming increasingly popular. Recently, with the improvements in laparoscopic surgery, various methods for the insertion of peritoneal dialysis catheters have been reported, indicating that the laparoscopic insertion is preferred over the open and percutaneous techniques. The aim of this study was to introduce and assess a simplified laparoscopic method for the insertion of peritoneal dialysis catheters in continuous ambulatory peritoneal dialysis (CAPD patients.Methods: We enrolled 79 consecutive end-stage renal patients (46 men and 33 women with a mean age of 50 years (range: 19-83 years in this study. During the surgery, a 5-mm trocar was placed in the left upper quadrant for the optics and another 5-mm trocar was placed to the left of the umbilicus. Using the second trocar, a tunnel was formed 2 cm left of the umbilical plane for the insertion of a Tenckhoff catheter. Under direct vision, the catheter was advanced into the abdomen. The catheter was tested for patency. Catheters of all subjects were capped for two weeks before dialysis initiation.Results: The mean duration of the operation was 15 minutes. Ten patients died during the follow-up period, all due to other medical problems, and six patients underwent renal transplantation; however, no deaths or complications were observed during surgery. Early onset complications were seen in 12 patients (15.1%. The most frequent late-onset medical and mechanical complications were peritonitis (6.3% and hernia (3.7%. During a follow-up period of four years, removal of the catheter was required in two patients as a result of peritonitis.Conclusion: We obtained a low complication rate and a high catheter survival rate with this laparoscopic insertion of the Tenckhoff catheter. We believe future experience will encourage the use of this safe, simple and quick procedure.

  18. Dedicated radial ventriculography pigtail catheter

    Energy Technology Data Exchange (ETDEWEB)

    Vidovich, Mladen I., E-mail: miv@uic.edu

    2013-05-15

    A new dedicated cardiac ventriculography catheter was specifically designed for radial and upper arm arterial access approach. Two catheter configurations have been developed to facilitate retrograde crossing of the aortic valve and to conform to various subclavian, ascending aortic and left ventricular anatomies. The “short” dedicated radial ventriculography catheter is suited for horizontal ascending aortas, obese body habitus, short stature and small ventricular cavities. The “long” dedicated radial ventriculography catheter is suited for vertical ascending aortas, thin body habitus, tall stature and larger ventricular cavities. This new design allows for improved performance, faster and simpler insertion in the left ventricle which can reduce procedure time, radiation exposure and propensity for radial artery spasm due to excessive catheter manipulation. Two different catheter configurations allow for optimal catheter selection in a broad range of patient anatomies. The catheter is exceptionally stable during contrast power injection and provides equivalent cavity opacification to traditional femoral ventriculography catheter designs.

  19. Endovascular technique using a snare and suture for retrieving a migrated peripherally inserted central catheter in the left pulmonary artery

    Science.gov (United States)

    Teragawa, Hiroki; Sueda, Takashi; Fujii, Yuichi; Takemoto, Hiroaki; Toyota, Yasushi; Nomura, Shuichi; Nakagawa, Keigo

    2013-01-01

    We report a successful endovascular technique using a snare with a suture for retrieving a migrated broken peripherally inserted central catheter (PICC) in a chemotherapy patient. A 62-year-old male received monthly chemotherapy through a central venous port implanted into his right subclavian area. The patient completed chemotherapy without complications 1 mo ago; however, he experienced pain in the right subclavian area during his last chemotherapy session. Computed tomography on that day showed migration of a broken PICC in his left pulmonary artery, for which the patient was admitted to our hospital. We attempted to retrieve the ectopic PICC through the right jugular vein using a gooseneck snare, but were unsuccessful because the catheter was lodged in the pulmonary artery wall. Therefore, a second attempt was made through the right femoral vein using a snare with triple loops, but we could not grasp the migrated PICC. Finally, a string was tied to the top of the snare, allowing us to curve the snare toward the pulmonary artery by pulling the string. Finally, the catheter body was grasped and retrieved. The endovascular suture technique is occasionally extremely useful and should be considered by interventional cardiologists for retrieving migrated catheters. PMID:24109502

  20. Prevalence and Risk Factors of Central Venous Stenosis among Prevalent Hemodialysis Patients, a Single Center Experience.

    Science.gov (United States)

    Osman, Osama O; El-Magzoub, Abdul-Rahman A; Elamin, Sarra

    2014-01-01

    Central vein stenosis (CVS) is a common complication of central venous catheter (CVC) insertion. In this study we evaluated the prevalence and risk factors of CVS among hemodialysis (HD) patients in a single center in Sudan, using Doppler ultrasound as a screening tool. The study included 106 prevalent HD patients. For every patient, we performed Duplex Doppler for the right and left jugular, subclavian and femoral veins. A patient was considered to have hemodynamically significant stenosis if the pre-stenosis to the post-stenosis velocities ratio was ≥ 2.5 or they had complete vein occlusion. Overall, 28.3% of patients had Doppler detected CVS, including 25.5% with hemodynamically significant stenosis and 2.8% with compromised flow. The prevalence of CVS was 68.4% among symptomatic patients compared to 19.5% in asymptomatic patients. The prevalence of CVS among patients with history of 0-1, 2-3 and ≥ 4 central venous catheters was 3.4%, 29.4% and 53.8% respectively (p=0.00). CVS was not more common in patients with history of previous/current jugular or femoral vein catheterization compared to no catheter placement in these veins (28.3% vs 28.6% and 35% vs 26.7% respectively; p >0.1). However, CVS was significantly more common in patients with previous/ current subclavian vein catheterization compared to no catheter placement in this vein (47.8% vs 22.9%, p = 0.02). CVS is highly prevalent among studied HD patients, particularly in the presence of suggestive clinical signs. The number of HD catheter placements and subclavian vein utilization for dialysis access impose a significantly higher risk of CVS.

  1. Septic Thrombophlebitis of the Cephalic Vein Caused by a Peripherally Inserted Venous Catheter

    Directory of Open Access Journals (Sweden)

    M Mirmohammadsadeghi

    2005-07-01

    Full Text Available Septic thrombophlebitis of a vein is a rare but life-threatening complication of an intravascular (IV catheter placed percutaneously in the veins. Most published clinical experiences with IV catheters, mainly in the outpatient settings, have reported very low rates of catheter-related bloodstream infection compared to rates with central venous catheters placed in a subclavian or internal jugular vein. Most of the complications reported with IV catheters have been non-infectious, particularly sterile phlebitis or thrombosis. We report a case of cephalic vein suppurative thrombophlebitis from an intravascular catheter and offer guidelines for diagnosis and management of this complication. Key words: Septic thrombophlebitis, Intravascular catheter, Suppurative thrombophlebitis

  2. 21 CFR 880.5200 - Intravascular catheter.

    Science.gov (United States)

    2010-04-01

    ... Devices § 880.5200 Intravascular catheter. (a) Identification. An intravascular catheter is a device that consists of a slender tube and any necessary connecting fittings and that is inserted into the patient's vascular system for short term use (less than 30 days) to sample blood, monitor blood pressure, or...

  3. Renal access in PNL under sonographic guidance: Do we really need to insert an open end ureteral catheter in dilated renal systems? A prospective randomized study.

    Science.gov (United States)

    Eryildirim, Bilal; Tuncer, Murat; Camur, Emre; Ustun, Fatih; Tarhan, Fatih; Sarica, Kemal

    2017-10-03

    To evaluate the true necessity of open end ureteral catheter insertion in patients with moderate to severe pelvicalyceal system dilation treated with percutaneous nephrolithotomy (PNL) under sonographic guidance. 50 cases treated with PNL under sonographic guidance in prone position for solitary obstructing renal stones were evaluated. Patients were randomly divided into two groups; Group 1: Patients in whom a open end ureteral catheter was inserted prior to the procedure; Group 2: Patients receiving no catheter before PNL. In addition to the duration of the procedure as a whole and also all relevant stages as well, radiation exposure time, hospitalization period, mean nephrostomy tube duration, mean drop in Hb levels and all intra and postoperative complications have been evaluated. Mean size of the stones was 308.5 ± 133.2 mm2. Mean total duration of the PNL procedure in cases with open end ureteral catheter was significantly longer than the other cases (p < 0.001). Evaluation of the outcomes of the PNL procedures revealed no statistically significant difference between two groups regarding the stone-free rates (86% vs 84%). Additionally, there was no significant difference with respect to the duration of nephrostomy tube, hospitalization period and secondary procedures needed, complication rates as well as the post-operative Hb drop levels in both groups (p = 0.6830). Our results indicate that the placement of an open end ureteral catheter prior to a PNL procedure performed under sonographic access may not be indicated in selected cases presenting with solitary obstructing renal pelvic and/or calyceal stones.

  4. Counterbalancing clinical supervision and independent practice: case studies in learning thoracic epidural catheter insertion.

    Science.gov (United States)

    Johnson, T

    2010-12-01

    Thoracic epidural catheter placement is an example of a demanding and high-risk clinical skill that junior anaesthetists need to learn by experience and under the supervision of consultants. This learning is known to present challenges that require further study. Ten consultant and 10 trainee anaesthetists in a teaching hospital were interviewed about teaching and learning this skill in the operating theatre, and a phenomenological analysis of their experience was performed. Trainee participation was limited by time pressure, lack of familiarity with consultants, and consultants' own need for clinical experience. There was a particular tension between safe and effective consultant practice and permitting trainees' independence. Three distinct stages of participation and assistance were identified from reports of ideal practice: early (part-task or basic procedure, consultant always present giving instruction and feedback), middle (independent practice with straightforward cases without further instruction), and late (skill extension and transfer). Learning assistance provided by consultants varied, but it was often not matched to the trainees' stages of learning. Negotiation of participation and assistance was recognized as being useful, but it did not happen routinely. There are many obstacles to trainees' participation in thoracic epidural catheter insertion, and learning assistance is not matched to need. A more explicit understanding of stages of learning is required to benefit the learning of this and other advanced clinical skills.

  5. Central venous pressure monitoring via peripherally or centrally inserted central catheters: a systematic review and meta-analysis.

    Science.gov (United States)

    Sanfilippo, Filippo; Noto, Alberto; Martucci, Gennaro; Farbo, Marco; Burgio, Gaetano; Biasucci, Daniele G

    2017-07-14

    The central venous pressure (CVP) is the most commonly used static marker of preload for guiding fluid therapy in critically ill patients, though its usefulness remains controversial. Centrally inserted central catheters (CICCs) are the gold-standard devices for CVP monitoring but peripherally inserted central catheters (PICCs) may represent a valid alternative. We undertook a systematic review and meta-analysis with the aim to investigate whether the difference between PICC- and CICC-measured CVP is not significant. We searched for clinical studies published in PubMed and EMBASE databases from inception until December 21st 2016. We included studies providing data on paired and simultaneous CVP measurement from PICCs and CICCs. We conducted two analyses on the values of CVP, the first one according to the total number of CVP assessments, the second one considering the number of patients recruited. Four studies matched the inclusion criteria, but only three of them provided data for the meta-analyses. Both analyses showed non-significant differences between PICC-measured and CICC-measured CVP: 1489 paired simultaneous CVP assessments (MD 0.16, 95%CI -0.14, 0.45, p = 0.30) on a total of 57 patients (MD 0.22, 95%CI -1.46, 1.91, p = 0.80). Both analyses showed no heterogeneity (I2 = 0%). Available evidence supports that CVP monitoring with PICCs is accurate and reproduces similar values to those obtained from CICCs. The possibility to monitor CVP should not be used among clinical criteria for preferring a CICC over a PICC line.

  6. A Simplified Technique of Percutaneous Hepatic Artery Port-Catheter Insertion for the Treatment of Advanced Hepatocellular Carcinoma with Portal Vein Invasion

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Sun Young [Hallym University Sacred Heart Hospital, Anyang (Korea, Republic of); Kim, Ah Hyun; Lee, Do Yun; Lee, Kwang Hun; Won, Jong Yun [Yonsei University College of Medicine, Severance Hospital, Seoul (Korea, Republic of); Kim, Kyung Ah [Inje University Ilsan Paik Hospital, Ilsan (Korea, Republic of)

    2010-12-15

    We assessed the outcomes of a simplified technique for the percutaneous placement of a hepatic artery port-catheter system for chemotherapy infusion in advanced hepatocellular carcinoma with portal vein invasion. From February 2003 to February 2008, percutaneous hepatic artery port-catheter insertion was performed in 122 patients who had hepatocellular carcinoma with portal vein invasion. The arterial access route was the common femoral artery. The tip of the catheter was wedged into the right gastroepiploic artery without an additional fixation device. A side hole was positioned at the distal common hepatic artery to allow the delivery of chemotherapeutic agents into the hepatic arteries. Coil embolization was performed only to redistribute to the hepatic arteries or to prevent the inadvertent delivery of chemotherapeutic agents into extrahepatic arteries. The port chamber was created at either the supra-inguinal or infra-inguinal region. Technical success was achieved in all patients. Proper positioning of the side hole was checked before each scheduled chemotherapy session by port angiography. Catheter-related complications occurred in 19 patients (16%). Revision was achieved in 15 of 18 patients (83%). This simplified method demonstrates excellent technical feasibility, an acceptable range of complications, and is hence recommended for the management of advanced hepatocellular carcinoma with portal vein thrombosis

  7. Inpatient Peripherally Inserted Central Venous Catheter Complications: Should Peripherally Inserted Central Catheter Lines Be Placed in the Intensive Care Unit Setting?

    Science.gov (United States)

    Martyak, Michael; Kabir, Ishraq; Britt, Rebecca

    2017-08-01

    Peripherally inserted central venous catheters (PICCs) are now commonly used for central access in the intensive care unit (ICU) setting; however, there is a paucity of data evaluating the complication rates associated with these lines. We performed a retrospective review of all PICCs placed in the inpatient setting at our institution during a 1-year period from January 2013 to December 2013. These were divided into two groups: those placed at the bedside in the ICU and those placed by interventional radiology in non-ICU patients. Data regarding infectious and thrombotic complications were collected and evaluated. During the study period, 1209 PICC line placements met inclusion criteria and were evaluated; 1038 were placed by interventional radiology in non-ICU patients, and 171 were placed at the bedside in ICU patients. The combined thrombotic and central line associated blood stream infection rate was 6.17 per cent in the non-ICU group and 10.53 per cent in the ICU group (P = 0.035). The thrombotic complication rate was 5.88 per cent in the non-ICU group and 7.60 per cent in the ICU group (P = 0.38), whereas the central line associated blood stream infection rate was 0.29 per cent in the non-ICU group and 2.92 per cent in the ICU group (P = 0.002). This study seems to suggest that PICC lines placed at the bedside in the ICU setting are associated with higher complication rates, in particular infectious complications, than those placed by interventional radiology in non-ICU patients. The routine placement of PICC lines in the ICU settings needs to be reevaluated given these findings.

  8. Paravertebral block catheter breakage by electrocautery during thoracic surgery.

    Science.gov (United States)

    Saeki, Noboru; Sugimoto, Yuki; Mori, Yoko; Kato, Takahiro; Miyoshi, Hirotsugu; Nakamura, Ryuji; Koga, Tomomichi

    2017-06-01

    Advantages of thoracic paravertebral analgesia (TPA) include placement of the catheter closer to the surgical field; however, the catheter can become damaged during the operation. We experienced a case of intraoperative TPA catheter breakage that prompted us to perform an experiment to investigate possible causes. A 50-year-old male underwent a thoracoscopic lower lobectomy under general anesthesia with TPA via an intercostal approach. Following surgery, it was discovered that the catheter had become occluded, as well as cut and fused, so we reopened the incision and removed the residual catheter. From that experience, we performed an experiment to examine electrocautery-induced damage in normal (Portex™, Smith's Medical), radiopaque (Perifix SoftTip™, BBraun), and reinforced (Perifix FX™, BBraun) epidural catheters (n = 8 each). Chicken meat was penetrated by each catheter and then cut by electrocautery. In the normal group, breakage occurred in 8 and occlusion in 6 of the catheters, and in the radiopaque group breakage occurred in 8 and occlusion in 7. In contrast, breakage occurred in only 3 and occlusion in none in the reinforced group, with the 5 without breakage remaining connected only by the spring coil. Furthermore, in 7 of the reinforced catheters, electric arc-induced thermal damage was observed at the tip of the catheter. A TPA catheter for thoracic surgery should be inserted via the median approach, or it should be inserted after surgery to avoid catheter damage during surgery.

  9. Usefulness of Interventional Treatment for Dysfunctional Hemodialysis Shunts of the Upper Arm by Means of the Retrograde Transradial Approach

    International Nuclear Information System (INIS)

    Shin, Hwa Seon; Shin, Tae Beom; Na, Jae Beom; Jung, Seong Hoon; Kim, Hyun Jung; Lee, Jung Eun; Song, Yun Gyu; Jung, Gyoo Sik

    2010-01-01

    This study was designed to evaluate the technical feasibility and clinical outcome of endovascular intervention using the retrograde transradial approach to treat dysfunctional hemodialysis shunts of the upper arms. During the last 3 years, sixteen procedures were performed by the transradial approach in 13 patients with dysfunctional hemodialysis shunts of the upper arms. The radial artery was accessed with the use of 20-gauge needle and a 6-Fr sheath. Angiography was performed using a 5-Fr catheter placed in the brachial artery, and then the interventional procedure was performed. The technical and clinical success rates, complications and patency rates were evaluated. Fistulography and percutaneous transluminal angioplasty via the transradial approach were performed in 16 cases of the 13 patients. Fistulography demonstrated stenosis in 7 cases and occlusions in 9 cases. Lesion multiplicity was identified in 9 out of 16 cases. Balloon angioplasty was performed in all cases and a stent was placed to overcome restenosis or to treat venous rupture in two cases. The technical success rate of balloon angioplasty was 87.5% (14/16) and the technical success rate with including stent insertion was 100% (16/16). The clinical success rate was 93.8%. There was one procedural-related complication. The primary patency rates at 6 and 12 months were 84.6% and 74%, respectively. The transradial approach seems to be technically feasible and effective for the management of insufficient hemodialysis shunts of the upper arms

  10. Pigtail Catheter: A Less Invasive Option for Pleural Drainage in Egyptian Patients with Recurrent Hepatic Hydrothorax

    Directory of Open Access Journals (Sweden)

    Mohamed Sharaf-Eldin

    2016-01-01

    Full Text Available Background and Aims. Treatment of hepatic hydrothorax is a clinical challenge. Chest tube insertion for hepatic hydrothorax is associated with high complication rates. We assessed the use of pigtail catheter as a safe and practical method for treatment of recurrent hepatic hydrothorax as it had not been assessed before in a large series of patients. Methods. This study was conducted on 60 patients admitted to Tanta University Hospital, Egypt, suffering from recurrent hepatic hydrothorax. The site of pigtail catheter insertion was determined by ultrasound guidance under complete aseptic measures and proper local anesthesia. Insertion was done by pushing the trocar and catheter until reaching the pleural cavity and then the trocar was withdrawn gradually while inserting the catheter which was then connected to a collecting bag via a triple way valve. Results. The use of pigtail catheter was successful in pleural drainage in 48 (80% patients with hepatic hydrothorax. Complications were few and included pain at the site of insertion in 12 (20% patients, blockage of the catheter in only 2 (3.3% patients, and rapid reaccumulation of fluid in 12 (20% patients. Pleurodesis was performed on 38 patients with no recurrence of fluid within three months of observation. Conclusions. Pigtail catheter insertion is a practical method for treatment of recurrent hepatic hydrothorax with a low rate of complications. This trial is registered with ClinicalTrials.gov Identifier: NCT02119169.

  11. Managing malignant pleural effusion with an indwelling pleural catheter: factors associated with spontaneous pleurodesis.

    Science.gov (United States)

    Wong, W M; Tam, T Cc; Wong, M Ky; Lui, M Ms; Ip, M Sm; Lam, D Cl

    2016-08-01

    Malignant pleural effusion can be recurrent despite active anti-cancer treatment. Significant malignant pleural effusion leads to debilitating dyspnoea and worsening quality of life in patients with advanced cancer. An indwelling pleural catheter offers a novel means to manage recurrent malignant pleural effusion and may remove the need for repeated thoracocentesis. Spontaneous pleurodesis is another unique advantage of indwelling pleural catheter placement but the factors associated with its occurrence are not clearly established. The aims of this study were to explore the safety of an indwelling pleural catheter in the management of symptomatic recurrent malignant pleural effusion, and to identify the factors associated with spontaneous pleurodesis. This case series with internal comparisons was conducted in the Division of Respiratory Medicine, Department of Medicine, Queen Mary Hospital, Hong Kong. All patients who underwent insertion of an indwelling pleural catheter from the initiation of such service from January 2010 to December 2014 were included for data analysis. Patients were monitored until December 2014, with the last catheter inserted in July 2014. Between 2010 and 2014, a total of 23 indwelling pleural catheters were inserted in 22 consecutive patients with malignant pleural effusion, including 15 (65.2%) cases with malignant pleural effusion as a result of metastatic lung cancer. Ten (43.5%) cases achieved minimal output according to defined criteria, in five of whom the pleural catheter was removed without subsequent re-accumulation of effusion (ie spontaneous pleurodesis). Factors associated with minimal output were the absence of trapped lung (P=0.036), shorter time from first appearance of malignant pleural effusion to catheter insertion (P=0.017), and longer time from catheter insertion till patient's death or end of study (P=0.007). An indwelling pleural catheter provides a safe means to manage symptomatic malignant pleural effusion

  12. The blind pushing technique for peripherally inserted central catheter placement through brachial vein puncture.

    Science.gov (United States)

    Lee, Jae Myeong; Cho, Young Kwon; Kim, Han Myun; Song, Myung Gyu; Song, Soon-Young; Yeon, Jae Woo; Yoon, Dae Young; Lee, Sam Yeol

    2018-03-01

    The objective of this study was to conduct a prospective clinical trial evaluating the technical feasibility and short-term clinical outcome of the blind pushing technique for placement of pretrimmed peripherally inserted central catheters (PICCs) through brachial vein access. Patients requiring PICC placement at any of the three participating institutions were prospectively enrolled between January and December 2016. The review boards of all participating institutions approved this study, and informed consent was obtained from all patients. PICC placement was performed using the blind pushing technique and primary brachial vein access. The following data were collected from unified case report forms: access vein, obstacles during PICC advancement, procedure time, and postprocedural complications. During the 12-month study period, 1380 PICCs were placed in 1043 patients. Of these, 1092 PICCs placed in 837 patients were enrolled, with 834 PICCs (76%) and 258 PICCs (34%) placed through brachial vein and nonbrachial vein access, respectively. In both arms, obstacles were most commonly noted in the subclavian veins (n = 220) and axillary veins (n = 94). Successful puncture of the access vein was achieved at first try in 1028 PICCs (94%). The technical success rate was 99%, with 1055 PICCs (97%) placed within 120 seconds of procedure time and 1088 PICCs (99%) having the tip located at the ideal position. Follow-up Doppler ultrasound detected catheter-associated upper extremity deep venous thrombosis (UEDVT) for 18 PICCs in 16 patients and late symptomatic UEDVT for 16 PICCs in 16 patients (3.1%). Catheter-associated UEDVT was noted for 28 PICCs (82%) and 6 PICCs (18%) placed through brachial vein and nonbrachial vein access, respectively. The incidence of obstacles and the procedure time (pushing technique and primary brachial vein access is technically feasible and may represent an alternative to the conventional PICC placement technique, having low incidences of

  13. Central Venous Catheter-Related Bloodstream Infection with Kocuria kristinae in a Patient with Propionic Acidemia

    OpenAIRE

    Kimura, Masato; Kawai, Eichiro; Yaoita, Hisao; Ichinoi, Natsuko; Sakamoto, Osamu; Kure, Shigeo

    2017-01-01

    Kocuria kristinae is a catalase-positive, coagulase-negative, Gram-positive coccus found in the environment and in normal skin and mucosa in humans; however, it is rarely isolated from clinical specimens and is considered a nonpathogenic bacterium. We describe a case of catheter-related bacteremia due to K. kristinae in a young adult with propionic acidemia undergoing periodic hemodialysis. The patient had a central venous catheter implanted for total parenteral nutrition approximately 6 mont...

  14. Risk of venous thromboembolism associated with peripherally inserted central catheters: a systematic review and meta-analysis.

    Science.gov (United States)

    Chopra, Vineet; Anand, Sarah; Hickner, Andy; Buist, Michael; Rogers, Mary Am; Saint, Sanjay; Flanders, Scott A

    2013-07-27

    Peripherally inserted central catheters (PICCs) are associated with an increased risk of venous thromboembolism. However, the size of this risk relative to that associated with other central venous catheters (CVCs) is unknown. We did a systematic review and meta-analysis to compare the risk of venous thromboembolism associated with PICCs versus that associated with other CVCs. We searched several databases, including Medline, Embase, Biosis, Cochrane Central Register of Controlled Trials, Conference Papers Index, and Scopus. Additional studies were identified through hand searches of bibliographies and internet searches, and we contacted study authors to obtain unpublished data. All human studies published in full text, abstract, or poster form were eligible for inclusion. All studies were of adult patients aged at least 18 years who underwent insertion of a PICC. Studies were assessed with the Newcastle-Ottawa risk of bias scale. In studies without a comparison group, the pooled frequency of venous thromboembolism was calculated for patients receiving PICCs. In studies comparing PICCs with other CVCs, summary odds ratios (ORs) were calculated with a random effects meta-analysis. Of the 533 citations identified, 64 studies (12 with a comparison group and 52 without) including 29 503 patients met the eligibility criteria. In the non-comparison studies, the weighted frequency of PICC-related deep vein thrombosis was highest in patients who were critically ill (13·91%, 95% CI 7·68-20·14) and those with cancer (6·67%, 4·69-8·64). Our meta-analysis of 11 studies comparing the risk of deep vein thrombosis related to PICCs with that related to CVCs showed that PICCs were associated with an increased risk of deep vein thrombosis (OR 2·55, 1·54-4·23, p<0·0001) but not pulmonary embolism (no events). With the baseline PICC-related deep vein thrombosis rate of 2·7% and pooled OR of 2·55, the number needed to harm relative to CVCs was 26 (95% CI 13-71). PICCs are

  15. Reducing unnecessary urinary catheter use and other strategies to prevent catheter-associated urinary tract infection: an integrative review.

    Science.gov (United States)

    Meddings, Jennifer; Rogers, Mary A M; Krein, Sarah L; Fakih, Mohamad G; Olmsted, Russell N; Saint, Sanjay

    2014-04-01

    Catheter-associated urinary tract infections (CAUTI) are costly, common and often preventable by reducing unnecessary urinary catheter (UC) use. To summarise interventions to reduce UC use and CAUTIs, we updated a prior systematic review (through October 2012), and a meta-analysis regarding interventions prompting UC removal by reminders or stop orders. A narrative review summarises other CAUTI prevention strategies including aseptic insertion, catheter maintenance, antimicrobial UCs, and bladder bundle implementation. 30 studies were identified and summarised with interventions to prompt removal of UCs, with potential for inclusion in the meta-analyses. By meta-analysis (11 studies), the rate of CAUTI (episodes per 1000 catheter-days) was reduced by 53% (rate ratio 0.47; 95% CI 0.30 to 0.64, pSMD) in catheterisation duration (days) was -1.06 overall (p=0.065) including a statistically significant decrease in stop-order studies (SMD -0.37; pSMD, -1.54; p=0.071). No significant harm from catheter removal strategies is supported. Limited research is available regarding the impact of UC insertion and maintenance technique. A recent randomised controlled trial indicates antimicrobial catheters provide no significant benefit in preventing symptomatic CAUTIs. UC reminders and stop orders appear to reduce CAUTI rates and should be used to improve patient safety. Several evidence-based guidelines have evaluated CAUTI preventive strategies as well as emerging evidence regarding intervention bundles. Implementation strategies are important because reducing UC use involves changing well-established habits.

  16. UK Renal Registry 15th annual report: Chapter 8 UK multisite peritoneal dialysis access catheter audit for first PD catheters 2011.

    Science.gov (United States)

    Briggs, Victoria; Pitcher, David; Braddon, Fiona; Fogarty, Damian; Wilkie, Martin

    2013-01-01

    The central paradigm of effective peritoneal dialysis (PD) is an appropriate standard of PD catheter function. The aim of the project was to develop an effective national PD access audit which would identify an 'appropriate standard' of PD catheter function. The UK Renal Registry collected centre specific information on various PD access outcome measures including catheter functionality and post-insertion complications. The first PD access audit covering England, Northern Ireland and Wales was conducted during April to June 2012 looking at incident dialysis patients in 2011. Forty three data collection spreadsheets were returned from a total of 65 centres describing 917 PD catheter placements. The median age of PD patients was 61 years and 61.5% were male. The proportion of patients initiated on PD in comparison to HD was lower in socially deprived areas. There was a relationship between the timing of nephrology referral and the likelihood of surgical assessment regarding PD catheter placement. Patients with diabetes did not have higher rates of PD catheter failure or of early peritonitis. A comparative PD catheter audit has the potential to provide valuable information on an important patient related outcome measure and lead to an improvement in patient experience. There was wide variation between centres of PD catheter use for late presenting patients. Overall patients were more likely to get a PD catheter if they had been known to the service for more than 1 year. The percutaneous insertion technique was associated with a higher early (less than 2 week) peritonitis rate and more catheter flow problems. Copyright © 2013 S. Karger AG, Basel.

  17. An artifice in the insertion of the Hickman catheter in small children

    African Journals Online (AJOL)

    Annals of Pediatric Surgery 2015, 11:59–60. Keywords: central venous catheter, children, Hickman catheter. Department of Transplantation and Pediatric Surgery, Graduate School of Medical Sciences, Kumamoto University, Kumamoto, Japan. Correspondence to Yuki Ohya, MD, PhD, Department of Transplantation and.

  18. Central venous catheter placement by an interventional radiology unit: an australian experience

    International Nuclear Information System (INIS)

    Lee, M. K. S.; Mossop, P. J.; Vrazas, J. I.

    2007-01-01

    The aim of this retrospective study was to analyse the outcomes of central venous catheter (CVC) placement carried out by an interventional radiology unit. A review of our hospital records identified 331 consecutive patients who underwent insertion of a tunnelled or non-tunnelled CVC between January 2000 and December 2004. Key outcome measures included the technical success rate of CVC insertion and the percentage of immediate ( 30 days) complications. A total of 462 CVCs were placed under radiological guidance, with an overall success rate of 98.9%. Immediate complications included one pneumothorax, which was diagnosed 7 days after subclavian CVC insertion, and eight episodes of significant haematoma or bleeding within 24 h of CVC insertion. No cases were complicated by arterial puncture or air embolus. Catheter-related sepsis occurred in 2% of non-tunnelled CVC and 8.9% of tunnelled CVC. The overall incidence of catheter-related sepsis was 0.17 per 100 catheter days. As the demand for chemotherapy and haemodialysis grows with our ageing population, interventional radiology suites are well placed to provide a safe and reliable service for the placement of central venous access devices

  19. Correction of malfunctioning peritoneal dialysis catheter with guidewire and stiffener under fluoroscopic guidance

    International Nuclear Information System (INIS)

    Lee, Seung Ryong; Baek, Kyong Hee; Jung, Gyoo Sik; Huh, Jin Do; Joh, Young Duk; Rim, Hark

    1997-01-01

    To determine the efficacy of correction of a malfunctioning peritoneal dialysis catheter with guidewire and stiffener under fluoroscopic guidance. Between November 1994 and March 1997, we performed 15 manipulations in 12 patients in whom a dual-cuff, straight Tenckhoff peritoneal dialysis catheter had been implanted due to chronic renal failure. The causes of catheter malfunctioning were inadequate drainage of the dialysate(n=14) and painful dialysis(n=1). Under fluoroscopic guidance, adhesiolysis and repositioning of the malfunctioning catheter were performed with an Amplatz Super Stiff guidewire and the stiffener from a biliary drainage catheter. The results of procedures were categorized as either immediate or durable success, this latter being defined as adequate catheter function for at least one month after the procedure. Immediate success was achieved in 14 of 15 procedures (93%), and durable success in 7 of 15(47%). The mean duration of catheter function was 157 (range, 30 to 578) days. After manipulation, abdominal pain developed in eight patients and peritonitis in two, but with conservative treatment, these symptoms improved. The correction of a malfunctioning peritoneal dialysis catheter with guidewire and stiffener under fluoroscopic guidance is an effective means of restoring catheter function and may be an effective alternative to surgical reimplantation of the catheter, or hemodialysis

  20. Correction of malfunctioning peritoneal dialysis catheter with guidewire and stiffener under fluoroscopic guidance

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seung Ryong; Baek, Kyong Hee; Jung, Gyoo Sik; Huh, Jin Do; Joh, Young Duk; Rim, Hark [Kosin Medical College, Pusan (Korea, Republic of)

    1997-11-01

    To determine the efficacy of correction of a malfunctioning peritoneal dialysis catheter with guidewire and stiffener under fluoroscopic guidance. Between November 1994 and March 1997, we performed 15 manipulations in 12 patients in whom a dual-cuff, straight Tenckhoff peritoneal dialysis catheter had been implanted due to chronic renal failure. The causes of catheter malfunctioning were inadequate drainage of the dialysate(n=14) and painful dialysis(n=1). Under fluoroscopic guidance, adhesiolysis and repositioning of the malfunctioning catheter were performed with an Amplatz Super Stiff guidewire and the stiffener from a biliary drainage catheter. The results of procedures were categorized as either immediate or durable success, this latter being defined as adequate catheter function for at least one month after the procedure. Immediate success was achieved in 14 of 15 procedures (93%), and durable success in 7 of 15(47%). The mean duration of catheter function was 157 (range, 30 to 578) days. After manipulation, abdominal pain developed in eight patients and peritonitis in two, but with conservative treatment, these symptoms improved. The correction of a malfunctioning peritoneal dialysis catheter with guidewire and stiffener under fluoroscopic guidance is an effective means of restoring catheter function and may be an effective alternative to surgical reimplantation of the catheter, or hemodialysis.

  1. [Peripheral intravenous catheter-related phlebitis].

    Science.gov (United States)

    van der Sar-van der Brugge, Simone; Posthuma, E F M Ward

    2011-01-01

    Phlebitis is a very common complication of the use of intravenous catheters. Two patients with an i.v. catheter complicated by thrombophlebitis are described. Patient A was immunocompromised due to chronic lymphatic leukaemia and developed septic thrombophlebitis with positive blood cultures for S. Aureus. Patient B was being treated with flucloxacillin because of an S. Aureus infection and developed chemical phlebitis. Septic phlebitis is rare, but potentially serious. Chemical or mechanical types of thrombophlebitis are usually less severe, but happen very frequently. Risk factors include: female sex, previous episode of phlebitis, insertion at (ventral) forearm, emergency placement and administration of antibiotics. Until recently, routine replacement of peripheral intravenous catheters after 72-96 h was recommended, but randomised controlled trials have not shown any benefit of this routine. A recent Cochrane Review recommends replacement of peripheral intravenous catheters when clinically indicated only.

  2. Evaluation of two different epidural catheters in clinical practice. narrowing down the incidence of paresthesia!

    Science.gov (United States)

    Bouman, E A C; Gramke, H F; Wetzel, N; Vanderbroeck, T H T; Bruinsma, R; Theunissen, M; Kerkkamp, H E M; Marcus, M A E

    2007-01-01

    Although epidural anesthesia is considered safe, several complications may occur during puncture and insertion of a catheter. Incidences of paresthesia vary between 0.2 and 56%. A prospective, open, cohort-controlled pilot study was conducted in 188 patients, ASA I-III, age 19-87 years, scheduled for elective surgery and epidural anesthesia. We evaluated a 20 G polyamide (standard) catheter and a 20 G combined polyurethane-polyamide (new) catheter. Spontaneous reactions upon catheter-insertion, paresthesia on questioning, inadvertent dural or intravascular puncture, and reasons for early catheter removal were recorded. The incidence of paresthesia reported spontaneously was 21.3% with the standard catheter and 16.7% with the new catheter. Systematically asking for paresthesia almost doubled the paraesthesia rate. Intravascular cannulation occurred in 5%. No accidental dural punctures occurred. An overall incidence of 13.3% of technical problems led to early catheter removal. The new catheter was at least equivalent to the standard regarding epidural success rate and safety : rate of paresthesia, intravascular and dural cannulation.

  3. Needle catheter duodenostomy: a technique for duodenal alimentation of birds.

    Science.gov (United States)

    Goring, R L; Goldman, A; Kaufman, K J; Roberts, C; Quesenberry, K E; Kollias, G V

    1986-11-01

    A technique for duodenal alimentation (needle catheter duodenostomy) of birds was developed, using the domestic pigeon (Columba livia) as the experimental model. A needle catheter was inserted into the descending duodenum of 5 pigeons and was secured to the body wall and dorsum of each bird. A liquid diet was administered daily (in equal amounts of 0, 4, 8, 12, and 16 hours) for 14 days without adverse effects. On day 15, the catheters were removed, and the birds immediately resumed normal consumption of a pigeon ration and water diet. Although 4 of the 5 birds had minor weight loss, dietary alterations probably could be used on an individual basis to alleviate this problem. After oral alimentation was resumed, the 5 birds exceeded their initial body weight within 7 days. Four weeks after catheter removal, positive-contrast radiographic evaluations indicated that the duodenum of each pigeon appeared normal. Needle catheter duodenostomy was a viable method of alimentation in the domestic pigeon. This technique should be applicable for other avian species requiring bypass of the upper gastrointestinal tract proximal to the region of catheter insertion in the duodenum.

  4. A pilot study to assess adductor canal catheter tip migration in a cadaver model.

    Science.gov (United States)

    Leng, Jody C; Harrison, T Kyle; Miller, Brett; Howard, Steven K; Conroy, Myles; Udani, Ankeet; Shum, Cynthia; Mariano, Edward R

    2015-04-01

    An adductor canal catheter may facilitate early ambulation after total knee arthroplasty, but there is concern over preoperative placement since intraoperative migration of catheters may occur from surgical manipulation and result in ineffective analgesia. We hypothesized that catheter type and subcutaneous tunneling may influence tip migration for preoperatively inserted adductor canal catheters. In a male unembalmed human cadaver, 20 catheter insertion trials were divided randomly into one of four groups: flexible epidural catheter either tunneled or not tunneled; or rigid stimulating catheter either tunneled or not tunneled. Intraoperative patient manipulation was simulated by five range-of-motion exercises of the knee. Distance and length measurements were performed by a blinded regional anesthesiologist. Changes in catheter tip to nerve distance (p = 0.225) and length of catheter within the adductor canal (p = 0.467) were not different between the four groups. Two of five non-tunneled stimulating catheters (40 %) were dislodged compared to 0/5 in all other groups (p = 0.187). A cadaver model may be useful for assessing migration of regional anesthesia catheters; catheter type and subcutaneous tunneling may not affect migration of adductor canal catheters based on this preliminary study. However, future studies involving a larger sample size, actual patients, and other catheter types are warranted.

  5. Evaluation of the safety of latrogenic lntestinal perforation during placement of percutaneous drainage catheter in rabbit

    International Nuclear Information System (INIS)

    Lee, Choon Hyeong; Oh, Joo Hyung; Park, Ga Young; Shin, Hong Sub; Kim, In Sub; Yoon, Yup; Lee, Dong Ho; Ko, Young Tae; Choi, Woo Suk; Lim, Joo Won

    1996-01-01

    To evaluate the safety of transgression of the bowel during intraperitoneal percutaneous catheter placement in an animal model. Eight 8-F straight catheters were percutaneously inserted into the small and large bowel of eight rabbits. In four animals, the catheters were left in place until autopsy, whereas in the remaining four, the catheters were withdrawn five days after insertion. Autopsy was performed in all animals ten days after catheter placement, and gross and microscopic examination was carried out. Transgressing the bowel during intraperitoneal percutaneous catheter placement did not contribute to any clinically significant complications. At autopsy, there was no bowel leakage, peritonitis, or abscess, although peritoneal adhesions were found around the catheter tract. Although further study is warranted, our study with an animal model indicated that transgression of the intestine during percutaneous placement of an intraabdominal catheter did not produce significant complications

  6. Evaluation of the safety of latrogenic lntestinal perforation during placement of percutaneous drainage catheter in rabbit

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Choon Hyeong; Oh, Joo Hyung; Park, Ga Young; Shin, Hong Sub; Kim, In Sub; Yoon, Yup; Lee, Dong Ho; Ko, Young Tae; Choi, Woo Suk; Lim, Joo Won [Kyunghee Univ. Hospital, Seoul (Korea, Republic of)

    1996-10-01

    To evaluate the safety of transgression of the bowel during intraperitoneal percutaneous catheter placement in an animal model. Eight 8-F straight catheters were percutaneously inserted into the small and large bowel of eight rabbits. In four animals, the catheters were left in place until autopsy, whereas in the remaining four, the catheters were withdrawn five days after insertion. Autopsy was performed in all animals ten days after catheter placement, and gross and microscopic examination was carried out. Transgressing the bowel during intraperitoneal percutaneous catheter placement did not contribute to any clinically significant complications. At autopsy, there was no bowel leakage, peritonitis, or abscess, although peritoneal adhesions were found around the catheter tract. Although further study is warranted, our study with an animal model indicated that transgression of the intestine during percutaneous placement of an intraabdominal catheter did not produce significant complications.

  7. [Vascular access guidelines for hemodialysis].

    Science.gov (United States)

    Rodríguez Hernández, J A; González Parra, E; Julián Gutiérrez, J M; Segarra Medrano, A; Almirante, B; Martínez, M T; Arrieta, J; Fernández Rivera, C; Galera, A; Gallego Beuter, J; Górriz, J L; Herrero, J A; López Menchero, R; Ochando, A; Pérez Bañasco, V; Polo, J R; Pueyo, J; Ruiz, Camps I; Segura Iglesias, R

    2005-01-01

    Quality of vascular access (VA) has a remarkable influence in hemodialysis patients outcomes. Dysfunction of VA represents a capital cause of morbi-mortality of these patients as well an increase in economical. Spanish Society of Neprhology, aware of the problem, has decided to carry out a revision of the issue with the aim of providing help in comprehensión and treatment related with VA problems, and achieving an homogenization of practices in three mayor aspects: to increase arteriovenous fistula utilization as first vascular access, to increment vascular access monitoring practice and rationalise central catheters use. We present a consensus document elaborated by a multidisciplinar group composed by nephrologists, vascular surgeons, interventional radiologysts, infectious diseases specialists and nephrological nurses. Along six chapters that cover patient education, creation of VA, care, monitoring, complications and central catheters, we present the state of the art and propose guidelines for the best practice, according different evidence based degrees, with the intention to provide help at the professionals in order to make aproppiate decissions. Several quality standars are also included.

  8. Conversion from temporary to tunneled catheters by nephrologists: report of a single-center experience

    Directory of Open Access Journals (Sweden)

    Silva BC

    2016-04-01

    Full Text Available Bruno C Silva, Camila E Rodrigues, Regina CRM Abdulkader, Rosilene M Elias Nephrology Division, Hospital das Clínicas, University of São Paulo, São Paulo, Brazil Background: Nephrologists have increasingly participated in the conversion from temporary catheters (TC to tunneled-cuffed catheters (TCCs for hemodialysis. Objective: To prospectively analyze the outcomes associated with TCC placement by nephrologists with expertise in such procedure, in different time periods at the same center. The impact of vancomycin or cefazolin as prophylactic antibiotics on the infection outcomes was also tested. Patients and methods: Hemodialysis patients who presented to such procedure were divided into two cohorts: A (from 2004 to 2008 and B (from 2013 to 2015. Time from TC to TCC conversion, prophylactic antibiotics, and reasons for TCC removal were evaluated. Results: One hundred and thirty patients were included in cohort A and 228 in cohort B. Sex, age, and follow-up time were similar between cohorts. Median time from TC to TCC conversion was longer in cohort A than in cohort B (14 [3; 30] vs 4 [1; 8] days, respectively; P<0.0001. Infection leading to catheter removal occurred in 26.4% vs 18.9% of procedures in cohorts A and B, respectively, and infection rate was 0.93 vs 0.73 infections per 1,000 catheter-days, respectively (P=0.092. Infection within 30 days from the procedure occurred in 1.4% of overall cohort. No differences were observed when comparing vancomycin and cefazolin as prophylactic antibiotics on 90-day infection-free TCC survival in a Kaplan–Meier model (log-rank = 0.188. TCC removal for low blood flow occurred in 8.9% of procedures. Conclusion: Conversion of TC to TCC by nephrologists had overall infection, catheter patency, and complications similar to data reported in the literature. Vancomycin was not superior to cefazolin as a prophylactic antibiotic. Keywords: renal dialysis, tunneled catheters, interventional nephrology

  9. Relato de caso: implante transparietohepático de cateter de longa permanência para diálise Case report: transhepatic insertion of long-term dialysis catheter

    Directory of Open Access Journals (Sweden)

    Felipe Nasser

    2007-12-01

    Full Text Available O implante transhepático de cateteres de diálise de longa permanência é um procedimento de exceção, utilizado para obter um acesso em pacientes com oclusão de veias centrais de membros superiores e inferiores. O caso descrito relata um paciente jovem, com história de 15 anos de diálise, que foi submetido no passado a um transplante renal sem sucesso. Esse paciente encontrava-se em urgência dialítica e oclusão comprovada de veias centrais de membros superiores e de veias ilíacas. Foi realizado o implante do cateter de longa permanência pelo acesso transparietohepático sob anestesia geral. A ponta do cateter foi posicionada ao nível do átrio direito. A diálise foi realizada satisfatoriamente no mesmo dia.Transhepatic insertion of long-term dialysis catheter is an exception procedure used to obtain access in patients with central vein occlusion of lower and upper limbs. We report on a case of a young patient with history of dialysis for 15 years, who was submitted to an unsuccessful renal transplantation. This patient was in dialytic emergency and had confirmed occlusion of upper limb central veins and iliac veins. Transhepatic insertion of a long-term catheter was performed under general anesthesia. The catheter tip was placed at the level of the right atrium. Dialysis was satisfactorily performed on the same day.

  10. Dosimetric equivalence of nonstandard HDR brachytherapy catheter patterns

    International Nuclear Information System (INIS)

    Cunha, J. A. M.; Hsu, I-C.; Pouliot, J.

    2009-01-01

    Purpose: To determine whether alternative high dose rate prostate brachytherapy catheter patterns can result in similar or improved dose distributions while providing better access and reducing trauma. Materials and Methods: Standard prostate cancer high dose rate brachytherapy uses a regular grid of parallel needle positions to guide the catheter insertion. This geometry does not easily allow the physician to avoid piercing the critical structures near the penile bulb nor does it provide position flexibility in the case of pubic arch interference. This study used CT datasets with 3 mm slice spacing from ten previously treated patients and digitized new catheters following three hypothetical catheter patterns: conical, bi-conical, and fireworks. The conical patterns were used to accommodate a robotic delivery using a single entry point. The bi-conical and fireworks patterns were specifically designed to avoid the critical structures near the penile bulb. For each catheter distribution, a plan was optimized with the inverse planning algorithm, IPSA, and compared with the plan used for treatment. Irrelevant of catheter geometry, a plan must fulfill the RTOG-0321 dose criteria for target dose coverage (V 100 Prostate >90%) and organ-at-risk dose sparing (V 75 Bladder 75 Rectum 125 Urethra <<1 cc). Results: The three nonstandard catheter patterns used 16 nonparallel, straight divergent catheters, with entry points in the perineum. Thirty plans from ten patients with prostate sizes ranging from 26 to 89 cc were optimized. All nonstandard patterns fulfilled the RTOG criteria when the clinical plan did. In some cases, the dose distribution was improved by better sparing the organs-at-risk. Conclusion: Alternative catheter patterns can provide the physician with additional ways to treat patients previously considered unsuited for brachytherapy treatment (pubic arch interference) and facilitate robotic guidance of catheter insertion. In addition, alternative catheter

  11. Indwelling urinary catheter management and catheter-associated urinary tract infection prevention practices in Nurses Improving Care for Healthsystem Elders hospitals.

    Science.gov (United States)

    Fink, Regina; Gilmartin, Heather; Richard, Angela; Capezuti, Elizabeth; Boltz, Marie; Wald, Heidi

    2012-10-01

    Indwelling urinary catheters (IUCs) are commonly used in hospitalized patients, especially elders. Catheter-associated urinary tract infections (CAUTIs) account for 34% of all health care associated infections in the United States, associated with excess morbidity and health care costs. Adherence to CAUTI prevention practices has not been well described. This study used an electronic survey to examine IUC care practices for CAUTI prevention in 3 areas-(1) equipment and alternatives and insertion and maintenance techniques; (2) personnel, policies, training, and education; and (3) documentation, surveillance, and removal reminders-at 75 acute care hospitals in the Nurses Improving the Care of Healthsystem Elders (NICHE) system. CAUTI prevention practices commonly followed included wearing gloves (97%), handwashing (89%), maintaining a sterile barrier (81%), and using a no-touch insertion technique (73%). Silver-coated catheters were used to varying degrees in 59% of the hospitals; 4% reported never using a catheter-securing device. Urethral meatal care was provided daily by 43% of hospitals and more frequently that that by 41% of hospitals. Nurses were the most frequently reported IUC inserters. Training in aseptic technique and CAUTI prevention at the time of initial nursing hire was provided by 64% of hospitals; however, only 47% annually validated competency in IUC insertion. Systems for IUC removal were implemented in 56% of hospitals. IUC documentation and routine CAUTI surveillance practices varied widely. Although many CAUTI prevention practices at NICHE hospitals are in alignment with evidence-based guidelines, there is room for improvement. Further research is needed to identify the effect of enhanced compliance with CAUTI prevention practices on the prevalence of CAUTI in NICHE hospitals. Copyright © 2012 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  12. A survey of the use of arterial catheters in anesthetized dogs and cats: 267 cases.

    Science.gov (United States)

    Trim, Cynthia M; Hofmeister, Erik H; Quandt, Jane E; Shepard, Molly K

    2017-01-01

    To describe the clinical practice of insertion of arterial catheters in anesthetized dogs and cats, to document complications of arterial catheterization, and to determine risk factors associated with the complications. Prospective clinical study and retrospective evaluation of medical records. University teaching hospital. Dogs (n = 251) and 13 cats anesthetized for clinical procedures with arterial catheters inserted for blood pressure monitoring. None. Details of the animal and catheter were collected at the time of anesthesia. On the following day, the catheter site was palpated and observed for abnormalities and the medical records of all animals were reviewed retrospectively for complications. Details of catheter placement were available for 216 catheters: 158 catheters in a dorsal pedal artery, 50 catheters in the median caudal (coccygeal) artery, 6 in the median artery, and 1 each in a cranial tibial and lingual artery. Blood pressure was obtained from 200 catheters, and 12 catheters failed before the end of anesthesia. Postoperative observational data obtained from 112 catheters described a palpable arterial pulse at 73 sites and no pulse at 21 sites. No risk factor for arterial occlusion was identified. No complications resulting from arterial catheterization were noted in the medical records. Arterial catheterization resulted in loss of a peripheral pulse postoperatively in 21/94 (22.3%) of animals examined, although no evidence of tissue ischemia was noted in the medical records of any of the patients in this study. These results suggest that insertion of a catheter in the dorsal pedal or coccygeal arteries was not associated with a high risk for complications. However, the course of arterial occlusion postoperatively warrants further investigation. © Veterinary Emergency and Critical Care Society 2016.

  13. Insertion of a straight peritoneal catheter in an arcuate subcutaneous tunnel by a tunneler: long-term experience.

    Science.gov (United States)

    Favazza, A; Petri, R; Montanaro, D; Boscutti, G; Bresadola, F; Mioni, G

    1995-01-01

    This study describes the results of the insertion of a straight Tenckhoff peritoneal catheter (PC) in an arcuate, caudally concave tunnel using a tunneler designed by the authors. It has a semicircular shape and a bending radius of 4.5 cm. A hospital renal unit. From June 1988 to February 1994, 112 straight Tenckhoff PCs, 62 with one deep cuff (single-cuff PC) and 50 with two cuffs (double-cuff PC), were inserted as first catheters in 112 patients (mean age 62 +/- 13 years), who underwent continuous ambulatory peritoneal dialysis (CAPD). The follow-up was 1099 months (mean 18 +/- 13 months) for single-cuff PCs and 1264 months (mean 25 +/- 15 months) for double-cuff PCs, respectively. After intraperitoneal placement of the PCs by median laparotomy, a 180 degrees arc bend tunnel, with both external and peritoneal exits directed downwards, was created by means of the tunneler. The rate of exit-site infection (ESI) was 0.27 episodes/year (epis/year). The probability of remaining ESI-free was 76%, 60%, and 55% at 1, 2, and 3 years. The rate of tunnel infection (TI) was 0.046 epis/year. The incidence of the double-cuff PC-related ESI and TI tended to be lower than the incidence observed with the single-cuff PC. Episodes of peritonitis were 60 (0.30 epis/year), where 6 were subsequent to ESI and/or TI. Two PCs were lost due to ESI, 3 due to TI, and 11 due to peritonitis. Drainage failure, due to displacement of the PC caused by straightening, involved 3 PCs; 2 were lost. PC survival was 92%, 82%, and 74% at 1, 2 and 3 years, respectively. By an easily used semicircular tunneler, the standard straight Tenckhoff PC can be stably positioned in an arcuate tunnel with both inner and outer exits directed downwards. This tunnel shape, as already suggested by some authors, appears to be an effective technical solution to reducing the PC-related complication rates.

  14. The dangers of long-term catheter drainage.

    Science.gov (United States)

    Lowthian, P

    There are many dangers associated with long-term urinary bladder drainage by catheter. For various reasons, the choice of catheter is important, and its initial insertion can be particularly hazardous. All catheterizations should, however, be safer when there is some urine (or other fluid) in the bladder. The appropriate choice of drainage system attached to the catheter can delay bacterial invasion of the bladder. Great care is needed to prevent blockage of the system, particularly when bacteriuria is present. Recent evidence indicates that some bacteria encourage the development of encrustations, so that, in some circumstances, catheters may become blocked within 24 hours. This, together with other considerations, strongly suggests that indwelling catheters should be changed at intervals of not more than 5 days. The practical implications of this are considered, as are the benefits that may accrue. Accidental catheter traction is another danger, and some possible methods of avoiding this are discussed. Finally, the need for a new kind of drainage-bag support is highlighted.

  15. A Study of Use of “PORT” Catheter in Patients with Cancer: A Single-Center Experience

    Directory of Open Access Journals (Sweden)

    Irappa Madabhavi

    2017-02-01

    Full Text Available Background: Effective and reliable venous access is one of the cornerstones of modern medical therapy in oncology. Materials and methods: This is a prospective observational study, which collected data of patients who require “PORT” catheter insertion for any cancer, at a tertiary care oncology hospital in Ahmadabad, Gujarat, India, during a 2-year period. Aims and objectives: The main objective of this study was to study the various complications and outcomes related to “PORT” catheters. Results: “PORT” catheter was inserted in 100 patients and was most commonly used in solid malignancies (n = 86, 86%, followed by hematologic malignancies (n = 14, 14%. Among the solid malignancies, breast cancer (38, 38% was the most common underlying disease, whereas among the hematologic malignancies, acute lymphoblastic leukemia (6, 6% was the most common underlying disease for “PORT” catheter insertion. Chemotherapy was started on the first day of “PORT” catheter in 74% of patients in the “PORT” study group. The various complications developed in the “PORT” study group in the descending order are as follows: 4 patients (4% developed early infection (⩽30 days after “PORT” placement, 4 (4% late infection (⩾30 days after “PORT” placement, 4 (4% bloodstream infection, 2 (2% local skin infection at the “PORT” insertion site, 2 (2% dislodgment of the “PORT” catheter, 2 (2% fracture of the “PORT” catheter, and 1 recurrent pleural effusion. One patient (1% developed thrombosis as the complication of “PORT” catheter insertion. Conclusions: The most disturbing aspect of treatment for a patient with cancer is multiple painful venipunctures made for administration of cytotoxic agents, antibiotics, blood products, and nutritional supplements. The focus of this prospective observational research is to study the various underlying diseases for which “PORT” catheter is needed in different solid and hematologic

  16. Ultrasound as a Screening Tool for Central Venous Catheter Positioning and Exclusion of Pneumothorax.

    Science.gov (United States)

    Amir, Rabia; Knio, Ziyad O; Mahmood, Feroze; Oren-Grinberg, Achikam; Leibowitz, Akiva; Bose, Ruma; Shaefi, Shahzad; Mitchell, John D; Ahmed, Muneeb; Bardia, Amit; Talmor, Daniel; Matyal, Robina

    2017-07-01

    Although real-time ultrasound guidance during central venous catheter insertion has become a standard of care, postinsertion chest radiograph remains the gold standard to confirm central venous catheter tip position and rule out associated lung complications like pneumothorax. We hypothesize that a combination of transthoracic echocardiography and lung ultrasound is noninferior to chest radiograph when used to accurately assess central venous catheter positioning and screen for pneumothorax. All operating rooms and surgical and trauma ICUs at the institution. Single-center, prospective noninferiority study. Patients receiving ultrasound-guided subclavian or internal jugular central venous catheters. During ultrasound-guided central venous catheter placement, correct positioning of central venous catheter was accomplished by real-time visualization of the guide wire and positive right atrial swirl sign using the subcostal four-chamber view. After insertion, pneumothorax was ruled out by the presence of lung sliding and seashore sign on M-mode. Data analysis was done for 137 patients. Chest radiograph ruled out pneumothorax in 137 of 137 patients (100%). Lung ultrasound was performed in 123 of 137 patients and successfully screened for pneumothorax in 123 of 123 (100%). Chest radiograph approximated accurate catheter tip position in 136 of 137 patients (99.3%). Adequate subcostal four-chamber views could not be obtained in 13 patients. Accurate positioning of central venous catheter with ultrasound was then confirmed in 121 of 124 patients (97.6%) as described previously. Transthoracic echocardiography and lung ultrasound are noninferior to chest x-ray for screening of pneumothorax and accurate central venous catheter positioning. Thus, the point of care use of ultrasound can reduce central venous catheter insertion to use time, exposure to radiation, and improve patient safety.

  17. US-guided placement of temporary internal jugular vein catheters: immediate technical success and complications in normal and high-risk patients

    International Nuclear Information System (INIS)

    Oguzkurt, Levent; Tercan, Fahri; Kara, Gulcan; Torun, Dilek; Kizilkilic, Osman; Yildirim, Tulin

    2005-01-01

    Objective: : To evaluate the technical success and immediate complication rates of temporary internal jugular vein (IJV) haemodialysis catheter placement in normal and high-risk patients. Methods and materials: Two-hundred and twenty temporary internal jugular vein catheters inserted under ultrasound guidance in 172 patients were prospectively analyzed. Of 172 patients, 93 (54%) were males and 79 (46%) were females (age range, 18-83; mean, 56.0 years). Of 220 catheters, 171 (78%) were placed in patients who had a risk factor for catheter placement like patients with disorder of haemostasis, poor compliance, and previous multiple catheter insertion in the same IJV. Forty-seven (21.3%) procedures were performed on bed-side. A catheter was inserted in the right IJV in 178 procedures (80.9%) and left IJV in 42 procedures. Of 172 patients, 112 (65%) had only one catheter placement and the rest had had more than one catheter placement (range, 1-5). Results: Technical success was achieved in all patients (100%). Average number of puncture was 1.24 (range, 1-3). One hundred and eighty-three insertions (83.1%) were single-wall punctures, whereas 37 punctures were double wall punctures. Nine (4%) minor complications were encountered. Inadvertent carotid artery puncture without a sequel in four procedures (1.8%), oozing of blood around the catheter in three procedures (1.4%), a small hematoma in one procedure (0.4%), and puncture through the pleura in one procedure (0.4%) without development of pneumothorax. Oozing of blood was seen only in patients with disorder of haemostasis. Conclusion: Ultrasound-guided placement of internal jugular vein catheters is very safe with very high success rate and few complications. It can safely be performed in high-risk patients, like patients with disorders of haemostasis and patients with previous multiple catheter insertion in the same vein

  18. Endovascular intervention for central venous cannulation in patients with vascular occlusion after previous catheterization.

    Science.gov (United States)

    Pikwer, Andreas; Acosta, Stefan; Kölbel, Tilo; Åkeson, Jonas

    2010-01-01

    This study was designed to assess endovascular intervention for central venous cannulation in patients with vascular occlusion after previous catheterization. Patients referred for endovascular management of central venous occlusion during a 42-month period were identified from a regional endovascular database, providing prospective information on techniques and clinical outcome. Corresponding patient records, angiograms, and radiographic reports were analyzed retrospectively. Sixteen patients aged 48 years (range 0.5-76), including 11 females, were included. All patients but 1 had had multiple central venous catheters with a median total indwelling time of 37 months. Eleven patients cannulated for hemodialysis had had significantly fewer individual catheters inserted compared with 5 patients cannulated for nutritional support (mean 3.6 vs. 10.2, pvenous occlusions. Patients were subjected to recanalization (n=2), recanalization and percutaneous transluminal angioplasty (n=5), or stenting for vena cava superior syndrome (n=1) prior to catheter insertion. The remaining 8 patients were cannulated by avoiding the occluded route. Central venous occlusion occurs particularly in patients under hemodialysis and with a history of multiple central venous catheterizations with large-diameter catheters and/or long total indwelling time periods. Patients with central venous occlusion verified by CT or MRT venography and need for central venous access should be referred for endovascular intervention.

  19. Change in Vascular Access and Hospitalization Risk in Long-Term Hemodialysis Patients

    Science.gov (United States)

    Wang, Weiling; Lazarus, J. Michael; Hakim, Raymond M.

    2010-01-01

    Background and objectives: Conversion from central venous catheters to a graft or a fistula is associated with lower mortality risk in long-term hemodialysis (HD) patients; however, a similar association with hospitalization risk remains to be elucidated. Design, setting, participants, & measurements: We conducted a prospective observational study all maintenance in-center HD patients who were treated in Fresenius Medical Care, North America legacy facilities; were alive on January 1, 2007; and had baseline laboratory data from December 2006. Access conversion (particularly from a catheter to a fistula or a graft) during the 4-month period from January 1 through April 30, 2007, was linked using Cox models to hospitalization risk during the succeeding 1-year follow-up period (until April 30, 2008). Results: The cohort (N = 79,545) on January 1, 2007 had 43% fistulas, 29% catheters, and 27% grafts. By April 30, 2007, 70,852 patients were still on HD, and among 19,792 catheters initially, only 10.3% (2045 patients) converted to either a graft or a fistula. With catheters as reference, patients who converted to grafts/fistulas had similar adjusted hazard ratios (0.69) as patients on fistulas (0.71), while patients with fistulas/grafts who converted to catheters did worse (1.22), all P < 0.0001. Conclusions: Catheters remain associated with the greatest hospitalization risk. Conversion from a catheter to either graft or fistula had significantly lower hospitalization risk relative to keeping the catheter. Prospective studies are needed to determine whether programs that reduce catheters will decrease hospitalization risk in HD patients. PMID:20884778

  20. Prevention of catheter-related blood stream infection.

    Science.gov (United States)

    Byrnes, Matthew C; Coopersmith, Craig M

    2007-08-01

    Catheter-related blood stream infections are a morbid complication of central venous catheters. This review will highlight a comprehensive approach demonstrated to prevent catheter-related blood stream infections. Elements of prevention important to inserting a central venous catheter include proper hand hygiene, use of full barrier precautions, appropriate skin preparation with 2% chlorhexidine, and using the subclavian vein as the preferred anatomic site. Rigorous attention needs to be given to dressing care, and there should be daily assessment of the need for central venous catheters, with prompt removal as soon as is practicable. Healthcare workers should be educated routinely on methods to prevent catheter-related blood stream infections. If rates remain higher than benchmark levels despite proper bedside practice, antiseptic or antibiotic-impregnated catheters can also prevent infections effectively. A recent program utilizing these practices in 103 ICUs in Michigan resulted in a 66% decrease in infection rates. There is increasing recognition that a comprehensive strategy to prevent catheter-related blood stream infections can prevent most infections, if not all. This suggests that thousands of infections can potentially be averted if the simple practices outlined herein are followed.

  1. Dexmedetomidine in a surgically inserted catheter for transversus abdominis plane block in donor hepatectomy: A prospective randomized controlled study.

    Science.gov (United States)

    Aboelela, Mohamed Adel; Kandeel, Al-Refaey; Elsayed, Usama; Elmorshedi, Mohamed; Elsarraf, Waleed; Elsayed, Eman; Elgawalby, Ahmed; Sultan, Ahmed Mohamed; Wahab, Mohamed Abdel; Yassen, Amr

    2018-01-01

    Transversus abdominis plane (TAP) block is a promising technique for analgesia after abdominal surgery. This prospective, randomized controlled trial assessed the effect of adding dexmedetomidine to bupivacaine in TAP block for donor hepatectomy. We hypothesized that this would improve postoperative morphine consumption and reduce analgesia related complication and inflammation. A total of 50 donor hepatectomy were enrolled in this study. Patients divided into two equal groups according to drugs used for TAP block. Group (B) received 20 ml of bupivacaine hydrochloride 0.25%, Group (BD) received 20 ml of bupivacaine hydrochloride 0.25% and 0.3 μg/kg dexmedetomidine, on both sides at the end of surgery and every 8 h for 48 h at right side only through inserted catheter. Primary outcome objective was morphine consumption at first 72 h. Secondary outcome objectives were morphine requirement, numbers of intake, time to first intake, pain score numerical analog scale (NAS), postoperative analgesia related complications, recovery of intestinal motility, and inflammatory markers. Data were analyzed, rescue morphine analgesia was significantly lower in (BD) group compared with (B) groups as considering total morphine consumption (B 4 ± 1.9, BD 1.5 ± 0.5, P = 0.03), numbers of morphine intake ( P = 0.04), morphine requirement ( P = 0.03), and first time of analgesia intake ( P = 0.04). NAS was significantly lower in group (BD) compared with group (B) group in the first 12 h (NAS 0 - P = 0.001, NAS 1 - P = 0.03). Adding dexmedetomidine improved gut motility, first oral intake without detectable anti-inflammatory effect. Adding dexmedetomidine to bupivacine in a surgically inserted catheter for TAP block in donor hepatectomy reduced morphine consumption without detectable anti-inflammatory effect.

  2. Complications of Percutaneous Nephrostomy, Percutaneous Insertion of Ureteral Endoprosthesis, and Replacement Procedures

    International Nuclear Information System (INIS)

    Kaskarelis, Ioannis S.; Papadaki, Marina G.; Malliaraki, Niki E.; Robotis, Epaminondas D.; Malagari, Katerina S.; Piperopoulos, Ploutarchos N.

    2001-01-01

    Purpose: The aim of the present study was to record and identify the frequency of complications following percutaneous nephrostomy, replacement of nephrostomy drains and percutaneous insertion of ureteral endoprostheses.Methods: During a 10-year period 341 patients were referred to our department with indications for percutaneous nephrostomy and/or percutaneous insertion of a ureteral endoprosthesis, and a total of 1036 interventional procedures were performed (nephrostomy, catheter change, stenting).Results: There were three major complications (0.29%): two patients died during the first 30 days after the procedure, due to aggravation of their condition caused by the procedure, and one patient had retroperitoneal bleeding requiring surgery. There were 76 complications of intermediate severity (7.33%): catheter or stent displacement (n = 37, 3.57%) catheter occlusion (n = 18, 1.73%), hematuria (n = 12, 1.16%), and urinary tract infection (n = 9, 0.87%). The 55 minor complications (5.3%) comprised inflammation of the skin at the site of insertion of the percutaneous catheter.Conclusion: The small number of complications observed during acts of interventional uroradiology prove transcutaneous manipulations to be safe medical procedures

  3. Swan-neck versus straight peritoneal dialysis catheter: Long-term effect on patient and method survival.

    Science.gov (United States)

    Filiopoulos, V; Biblaki, D; Takouli, L; Dounavis, A; Hadjiyannakos, D; Vlassopoulos, D

    2016-09-01

    Peritoneal dialysis (PD) is limited mainly by a higher technique failure rate as compared to hemodialysis (HD), catheter malfunction being an important reason. Intra- and extra-peritoneal catheter configuration may be associated with mechanical and infectious complications affecting method survival. We report our experience with two extra-peritoneal catheter configurations: the straight and the swan-neck (SN) catheters. A total of 85 consecutive patients, 58 males and 27 females were included in the study. Among them, 26 were diabetics; 52 were treated with automated PD (APD) and 33 with continuous ambulatory PD (CAPD). Straight catheters were used in 38 patients (straight group) and SN catheters in 47 patients (SN group). Straight catheters were mostly used in the first 6-year period while SN catheters in the last 6-year period. The baseline demographics were similar between the two groups. A significantly higher frequency of APD use was observed in SN group. Technique survival was better with SN versus straight (log-rank test, P = 0.01) while patient and catheter survival were similar. A better technique survival is noted in our group of patients with SN catheters. An additional factor could be the significantly higher frequency of APD use in this group. Changes in PD solutions' composition could also contribute to improvement in technique survival. The outcome for patients and catheter types used was similar.

  4. Reducing unnecessary urinary catheter use and other strategies to prevent catheter-associated urinary tract infection: an integrative review

    Science.gov (United States)

    Meddings, Jennifer; Rogers, Mary A M; Krein, Sarah L; Fakih, Mohamad G; Olmsted, Russell N; Saint, Sanjay

    2014-01-01

    Background Catheter-associated urinary tract infections (CAUTI) are costly, common and often preventable by reducing unnecessary urinary catheter (UC) use. Methods To summarise interventions to reduce UC use and CAUTIs, we updated a prior systematic review (through October 2012), and a meta-analysis regarding interventions prompting UC removal by reminders or stop orders. A narrative review summarises other CAUTI prevention strategies including aseptic insertion, catheter maintenance, antimicrobial UCs, and bladder bundle implementation. Results 30 studies were identified and summarised with interventions to prompt removal of UCs, with potential for inclusion in the meta-analyses. By meta-analysis (11 studies), the rate of CAUTI (episodes per 1000 catheter-days) was reduced by 53% (rate ratio 0.47; 95% CI 0.30 to 0.64, p<0.001) using a reminder or stop order, with five studies also including interventions to decrease initial UC placement. The pooled (nine studies) standardised mean difference (SMD) in catheterisation duration (days) was −1.06 overall (p=0.065) including a statistically significant decrease in stop-order studies (SMD −0.37; p<0.001) but not in reminder studies (SMD, −1.54; p=0.071). No significant harm from catheter removal strategies is supported. Limited research is available regarding the impact of UC insertion and maintenance technique. A recent randomised controlled trial indicates antimicrobial catheters provide no significant benefit in preventing symptomatic CAUTIs. Conclusions UC reminders and stop orders appear to reduce CAUTI rates and should be used to improve patient safety. Several evidence-based guidelines have evaluated CAUTI preventive strategies as well as emerging evidence regarding intervention bundles. Implementation strategies are important because reducing UC use involves changing well-established habits. PMID:24077850

  5. Fifty years of hemodialysis access literature: The fifty most cited publications in the medical literature.

    Science.gov (United States)

    Skripochnik, Edvard; O'Connor, David J; Trestman, Eric B; Lipsitz, Evan C; Scher, Larry A

    2018-02-01

    Objectives The modern era of hemodialysis access surgery began with the publication in 1966 by Brescia et al. describing the use of a surgically created arteriovenous fistula. Since then, the number of patients on chronic hemodialysis and the number of publications dealing with hemodialysis access have steadily increased. We have chronicled the increase in publications in the medical literature dealing with hemodialysis access by evaluating the characteristics of the 50 most cited articles. Methods We queried the Science Citation Index from the years 1960-2014. Articles were selected based on a subject search and were ranked according to the number of times they were cited in the medical literature. Results The 50 most frequently cited articles were selected for further analysis and the number of annual publications was tracked. The landmark publication by Dr Brescia et al. was unequivocally the most cited article dealing with hemodialysis access (1109 citations). The subject matter of the papers included AV fistula and graft (9), hemodialysis catheter (9), complications and outcomes (24), and other topics (8). Most articles were published in nephrology journals (33), with fewer in surgery (7), medicine (7), and radiology (3) journals. Of the 17 journals represented, Kidney International was the clear leader, publishing 18 articles. There has been an exponential rise in the frequency of publications regarding dialysis access with 42 of 50 analyzed papers being authored after 1990. Conclusion As the number of patients on hemodialysis has increased dramatically over the past five decades, there has been a commensurate increase in the overall number of publications related to hemodialysis access.

  6. A COMPARATIVE ANALYSIS OF PERCUTANEOUS AND OPEN SURGICAL TECHNIQUESFOR PERITONEAL CATHETER PLACEMENT.

    LENUS (Irish Health Repository)

    Medani, Samar

    2012-05-01

    BACKGROUND: Peritoneal dialysis (PD) is the preferred available option of renal replacement therapy for a significant number of end-stage kidney disease patients. A major limiting factor to the successful continuation of PD is the long-term viability of the PD catheter (PDC). Bedside percutaneous placement of the PDC is not commonly practiced despite published data encouraging use of this technique. Its advantages include faster recovery and avoidance of general anesthesia.♢ METHODS: We carried out a retrospective analysis of the outcomes of 313 PDC insertions at our center, comparing all percutaneous PDC insertions between July 1998 and April 2010 (group P, n = 151) with all surgical PDC insertions between January 2003 and April 2010 (group S, n = 162).♢ RESULTS: Compared with group P patients, significantly more group S patients had undergone previous abdominal surgery or PDC insertion (41.8% vs 9.3% and 33.3% vs 3.3% respectively, p = 0.00). More exit-site leaks occurred in group P than in group S (20.5% vs 6.8%, p = 0.002). The overall incidence of peritonitis was higher in group S than in group P (1 episode in 19 catheter-months vs 1 episode in 26 catheter-months, p = 0.017), but the groups showed no significant difference in the peritonitis rate within 1 month of catheter insertion (5% in group P vs 7.4% in group S, p =0.4) or in poor initial drainage or secondary drainage failure (9.9% vs 11.7%, p = 0.1, and 7.9% vs 12.3%, p = 0.38, for groups P and S respectively). Technical survival at 3 months was significantly better for group P than for group S (86.6% vs 77%, p = 0.037); at 12 months, it was 77.7% and 68.7% respectively (p = 0.126). No life-threatening complications attributable to the insertion of the PDC occurred in either group.♢ CONCLUSIONS: Our analysis demonstrates further encouraging outcomes of percutaneous PDC placement compared with open surgical placement. However, the members of the percutaneous insertion group were primarily a

  7. [Anatomical and clinical evaluation regarding the removal of the peritoneal dialysis catheter].

    Science.gov (United States)

    Tăranu, T; Covic, A; Târcoveanu, E; Florea, Laura

    2005-01-01

    To describe CAPD technique survival and causes for catheter removal. The study included 320 end stage renal disease (ESRD) patients, initiated on CAPD between 1995-2003. Definitive catheter removal was required in 44 cases (15.1%), 11 of these (3.79%) receiving renal transplant. Causes for catheter removal were: mechanical obstruction by fibrin (8 cases/2.75%), obstruction by tub bower (1 case/0.34%), by omental muff (6 cases/2%); abdominal wall sepsis (30 cases/ 10.3%); non-responsive bacterial peritonitis (13 cases/4.05%), fungal peritonitis (7 cases/ 2.4%), fecal peritonitis (2 cases/0.68%); transfer to hemodialysis program (31 cases/10.6%); renal transplant (11 cases/3.79%); emergency surgical pathology for: necrotic-hemorrhagic pancreatitis (two cases), intestinal occlusions (six cases), locked hernias (three cases) and locked eventrations(three cases), appendicular peritonitis (two cases). Mortality associated with these procedures and underlying pathology was 1.73%.

  8. Decreasing dialysis catheter rates by creating a multidisciplinary dialysis access program.

    Science.gov (United States)

    Rosenberry, Patricia M; Niederhaus, Silke V; Schweitzer, Eugene J; Leeser, David B

    2018-03-01

    Centers for Medicare and Medicaid Services have determined that chronic dialysis units should have 45%. A multidisciplinary program was established with goals of decreasing catheter rates in order to decrease central line-associated bloodstream infections, decrease mortality associated with central line-associated bloodstream infection, decrease hospital days, and provide savings to the healthcare system. We collected the catheter rates within three dialysis centers served over a 5-year period. Using published data surrounding the incidence and related costs of central line-associated bloodstream infection and mortality per catheter day, the number of central line-associated bloodstream infection events, the costs, and the related mortality could be determined prior to and after the initiation of the dialysis access program. An organized dialysis access program resulted in a 82% decrease in the number of central venous catheter days which lead to a concurrent reduction in central line-associated bloodstream infection and deaths. As a result of creating an access program, central venous catheter rates decreased from an average rate of 45% to 8%. The cost savings related to the program was calculated to be over US$5 million. The decrease in the number of mortalities is estimated to be between 13 and 27 patients. We conclude that a formalized access program decreases catheter rates, central line-associated bloodstream infection, and the resultant hospitalizations, mortality, and costs. Areas with high hemodialysis catheter rates should develop access programs to better serve their patient population.

  9. Clinical evaluation of the use of an intracardiac electrocardiogram to guide the tip positioning of peripherally inserted central catheters.

    Science.gov (United States)

    Zhao, Ruiyi; Chen, Chunfang; Jin, Jingfen; Sharma, Komal; Jiang, Nan; Shentu, Yingqin; Wang, Xingang

    2016-06-01

    The use of peripherally inserted central catheters (PICCs) provides important central venous accesses for clinical treatments, tests and monitoring. Compared with the traditional methods, intracardiac electrocardiogram (ECG)-guided method has the potential to guide more accurate tip positioning of PICCs. This study aimed to clinically evaluate the effectiveness of an intracardiac ECG to guide the tip positioning by monitoring characteristic P-wave changes. In this study, eligible patients enrolled September 2011 to May 2012 according to the inclusion and exclusion criteria received the catheterization monitored by intracardiac ECG. Then chest radiography was performed to check the catheter position. The results revealed that, with 117 eligible patients, all bar one patient who died (n = 116) completed the study, including 60 males and 56 females aged 51.2 ± 15.1 years. Most (n = 113, > 97%) had characteristic P-wave changes. The intracardiac ECG-guided positioning procedure achieved correct placement for 112 patients (96.56%), demonstrating 99.12% sensitivity and 100% specificity. In conclusion, the intracardiac ECG can be a promising technique to guide tip positioning of PICCs. However, since the sample size in this study is limited, more experience and further study during clinical practice are needed to demonstrate achievement of optimal catheterization outcomes. © 2015 John Wiley & Sons Australia, Ltd.

  10. Emergency Department Catheter-Associated Urinary Tract Infection Prevention: Multisite Qualitative Study of Perceived Risks and Implemented Strategies.

    Science.gov (United States)

    Carter, Eileen J; Pallin, Daniel J; Mandel, Leslie; Sinnette, Corine; Schuur, Jeremiah D

    2016-02-01

    Existing knowledge of emergency department (ED) catheter-associated urinary tract infection (CAUTI) prevention is limited. We aimed to describe the motivations, perceived risks for CAUTI acquisition, and strategies used to address CAUTI risk among EDs that had existing CAUTI prevention programs. In this qualitative comparative case study, we enrolled early-adopting EDs, that is, those using criteria for urinary catheter placement and tracking the frequency of catheters placed in the ED. At 6 diverse facilities, we conducted 52 semistructured interviews and 9 focus groups with hospital and ED participants. All ED CAUTI programs originated from a hospitalwide focus on CAUTI prevention. Staff were motivated to address CAUTI because they believed program compliance improved patient care. ED CAUTI prevention was perceived to differ from CAUTI prevention in the inpatient setting. To identify areas of ED CAUTI prevention focus, programs examined ED workflow and identified 4 CAUTI risks: (1) inappropriate reasons for urinary catheter placement; (2) physicians' limited involvement in placement decisions; (3) patterns of urinary catheter overuse; and (4) poor insertion technique. Programs redesigned workflow to address risks by (1) requiring staff to specify the medical reason for catheter at the point of order entry and placement; (2) making physicians responsible for determining catheter use; (3) using catheter alternatives to address patterns of overuse; and (4) modifying urinary catheter insertion practices to ensure proper placement. Early-adopting EDs redesigned workflow to minimize catheter use and ensure proper insertion technique. Assessment of ED workflow is necessary to identify and modify local practices that may increase CAUTI risk.

  11. Improving Nurses' Peripheral Intravenous Catheter Insertion Knowledge, Confidence, and Skills Using a Simulation-Based Blended Learning Program

    Science.gov (United States)

    Keleekai, Nowai L.; Schuster, Catherine A.; Murray, Connie L.; King, Mary Anne; Stahl, Brian R.; Labrozzi, Laura J.; Gallucci, Susan; LeClair, Matthew W.; Glover, Kevin R.

    2016-01-01

    Introduction Peripheral intravenous catheter (PIVC) insertion is one of the most common invasive procedures performed in a hospital, but most nurses receive little formal training in this area. Blended PIVC insertion training programs that incorporate deliberate simulated practice have the potential to improve clinical practice and patient care. Methods The study was a randomized, wait-list control group with crossover using nurses on three medical/surgical units. Baseline PIVC knowledge, confidence, and skills assessments were completed for both groups. The intervention group then received a 2-hour PIVC online course, followed by an 8-hour live training course using a synergistic mix of three simulation tools. Both groups were then reassessed. After crossover, the wait-list group received the same intervention and both groups were reassessed. Results At baseline, both groups were similar for knowledge, confidence, and skills. Compared with the wait-list group, the intervention group had significantly higher scores for knowledge, confidence, and skills upon completing the training program. After crossover, the wait-list group had similarly higher scores for knowledge, confidence, and skills than the intervention group. Between the immediate preintervention and postintervention periods, the intervention group improved scores for knowledge by 31%, skills by 24%, and decreased confidence by 0.5%, whereas the wait-list group improved scores for knowledge by 28%, confidence by 16%, and skills by 15%. Conclusions Results demonstrate significant improvements in nurses' knowledge, confidence, and skills with the use of a simulation-based blended learning program for PIVC insertion. Transferability of these findings from a simulated environment into clinical practice should be further explored. PMID:27504890

  12. Randomized clinical trial of pigtail catheter versus chest tube in injured patients with uncomplicated traumatic pneumothorax.

    Science.gov (United States)

    Kulvatunyou, N; Erickson, L; Vijayasekaran, A; Gries, L; Joseph, B; Friese, R F; O'Keeffe, T; Tang, A L; Wynne, J L; Rhee, P

    2014-01-01

    Small pigtail catheters appear to work as well as the traditional large-bore chest tubes in patients with traumatic pneumothorax, but it is not known whether the smaller pigtail catheters are associated with less tube-site pain. This study was conducted to compare tube-site pain following pigtail catheter or chest tube insertion in patients with uncomplicated traumatic pneumothorax. This prospective randomized trial compared 14-Fr pigtail catheters and 28-Fr chest tubes in patients with traumatic pneumothorax presenting to a level I trauma centre from July 2010 to February 2012. Patients who required emergency tube placement, those who refused and those who could not respond to pain assessment were excluded. Primary outcomes were tube-site pain, as assessed by a numerical rating scale, and total pain medication use. Secondary outcomes included the success rate of pneumothorax resolution and insertion-related complications. Forty patients were enrolled. Baseline characteristics of 20 patients in the pigtail catheter group were similar to those of 20 patients in the chest tube group. No patient had a flail chest or haemothorax. Pain scores related to chest wall trauma were similar in the two groups. Patients with a pigtail catheter had significantly lower mean(s.d.) tube-site pain scores than those with a chest tube, at baseline after tube insertion (3.2(0.6) versus 7.7(0.6); P pneumothorax, use of a 14-Fr pigtail catheter is associated with reduced pain at the site of insertion, with no other clinically important differences noted compared with chest tubes. NCT01537289 (http://clinicaltrials.gov). © 2013 BJS Society Ltd. Published by John Wiley & Sons Ltd.

  13. Using the Theory of Planned Behavior to explore hospital-based nurses' intention to use peripherally inserted central catheter (PICC): a survey study.

    Science.gov (United States)

    Bertani, Laura; Carone, Maria; Caricati, Luca; Demaria, Serena; Fantuzzi, Silvia; Guarasci, Alessandro; Pirazzoli, Luca

    2016-11-22

    The peripherally inserted central catheters (PICC) have become an alternative to the traditional CVC. PICCs are usually inserted by trained nurses who decided to attend and complete a special training on PICC insertion and management. The present work aimed to investigate the intention of using PICC in a sample of hospital-based nurses using the theory of planned behavior as theoretical framework. A cross-sectional design was used in which a questionnaire was delivered to 199 nurses. According to the theory of planned behavior, the attitude toward the use of PICC, subjective norms and perceived self-efficacy predicted the intention to use PICC. Contrary to the expectations, the effect of subjective norms on intention to use PICC was mediated by attitude and self-efficacy. Finally, age of participants was negatively related to the intention to use the PICC. The theory of planned behavior offers a useful framework to explain nurses' intention to use PICC. Shared norms favoring the use of PICC seem to increase both nurse's positive attitudes and self-efficacy whit respect to the use of these devices. Thus, it appears that to train professionals individually does not necessarily results in an increased use of PICC.

  14. Health-related quality of life of cancer patients with peripherally inserted central catheter: a pilot study.

    Science.gov (United States)

    Kang, Junren; Chen, Wei; Sun, Wenyan; Ge, Ruibin; Li, Hailong; Ma, Enling; Su, Qingxia; Cheng, Fang; Hong, Jinhua; Zhang, Yuanjuan; Lei, Cheng; Wang, Xinchuan; Jin, Aiyun; Liu, Wanli

    2017-09-11

    This pilot exploratory study aimed to compare the health-related quality of life (HRQOL) among patients diagnosed with different types of cancer receiving peripherally inserted central catheters (PICCs). A multicenter cross-section study of cancer patients with PICCs was performed from February 1, 2013 to April 24, 2014. The primary objective of this study was to compare HRQOL in different cancer type patients with PICC. HRQOL was examined based on European Organisation for Research and Treatment of Cancer Quality-of-Life Questionnaire-Core 30 (EORTC QLQ-C30). Multiple linear regression models were conducted for coping with potential confounding variables. We also examined PICC-related quality of daily life with a self-made questionnaire. Three hundred and fifty-seven cancer patients with PICC completed the survey in nine teaching hospitals. Lung cancer patients with PICC reported the worst dyspnea. Digestive tract cancer patients reported the worst appetite loss. Patients with hematologic malignancy reported the worst emotional, social function, fatigue and financial impact. Breast cancer patients reported better HRQOL. Baseline variables were proven not significant predictors of EORTC QLQ-C30 global health status. In self-made survey, pain after PICC insertion was null or a little in 98.6% of cancer patients. Limitation of upper extremity activity was null or a little in 94.1% of patients. HRQOL varies in different types of cancer patients with PICC. PICC may have a low impact on cancer patients' HRQOL. Further large sample studies are needed.

  15. Effect of steel and teflon infusion catheters on subcutaneous adipose tissue blood flow and infusion counter pressure in humans

    DEFF Research Database (Denmark)

    Højbjerre, Lise; Skov-Jensen, Camilla; Kaastrup, Peter

    2009-01-01

    BACKGROUND: Subcutaneous tissue is an important target for drug deposition or infusion. A local trauma may induce alterations in local microcirculation and diffusion barriers with consequences for drug bioavailability. We examined the influence of infusion catheters' wear time on local...... microcirculation and infusion counter pressure. METHODS: One steel catheter and one Teflon (Dupont, Wilmington, DE) catheter were inserted in subcutaneous, abdominal adipose tissue (SCAAT) in 10 healthy, lean men. The catheters were infused with isotonic saline at a rate of 10 microL/h for 48 h. Another steel...... catheter and a Teflon catheter were inserted contralateral to the previous catheters after 48 h. The infusion counter pressure was measured during a basal infusion rate followed by a bolus infusion. The measurements during a basal rate infusion were repeated after the bolus infusion. Adipose tissue blood...

  16. Ultrasound Thrombolysis in Hemodialysis Access: In Vitro Investigation

    International Nuclear Information System (INIS)

    Wildberger, Joachim Ernst; Schmitz-Rode, Thomas; Haage, Patrick; Pfeffer, Joachim; Ruebben, Alexander; Guenther, Rolf W.

    2001-01-01

    Purpose: To evaluate the effectiveness of ultrasound thrombolysis in occluded hemodialysis access shunts using an in vitro model.Methods: Thrombosed hemodialysis accesses were simulated by clotted bovine blood in a flow model (silicone tubing; inner diameters 4, 6, and 9 mm). After retrograde and antegrade sheath placement (7 Fr), mechanical thrombolysis was performed using an ultrasound probe (Acolysis, Angiosonics, Morrisville, NC, USA). The tip of the device measured 2.2 mm in diameter. During sonication, the catheter was moved slowly back and forth using an over-the-wire system. Thirty complete occlusions [tubing diameters 4 mm (n = 12), 6 mm (n = 12), 9 mm (n = 6)] were treated. Initial thrombus weights were 3.5 (± 0.76) g, 7.7 (± 1.74) g, and 19.4 (± 2.27) g for the three diameters. Maximum sonication time was 15 min for each probe.Results: With this device, we were able to restore a continuous lumen in all 12 occluded 4∼mm silicone tubes. No wall-adherent thrombi remained after sonication for 3.5-9.6 min. In hemodialysis access models with diameters of 6 mm, thrombus fragments persisted in 25% (3/12 accesses). These were located in the medial portion of the access loop and near to the puncture sites. However, flow was re-established after 5.0-13.0 min of treatment in all settings. Mechanical dissolution of thrombus material failed in five of six access models with diameters of 9 mm, even though ultrasound energy was applied for the maximum of 15 min.Conclusion: In a clotted hemodialysis shunt model, successful ultrasound thrombolysis was limited to small access diameters and small amounts of thrombus

  17. Intra-vesical knot of bladder catheter in an extremely low birthweight neonate: A case report

    Directory of Open Access Journals (Sweden)

    Paula M.Y. Tang

    2015-07-01

    Full Text Available Premature and extremely low birth weight (ELBW neonates are at high risk of developing multiple co-morbidities and often require urinary catheterization for various medical indications. Intra-vesical knotting of bladder catheter is a known but uncommon complication of this procedure. We report a case of an ELBW baby boy with a knotted bladder catheter requiring surgical retrieval. After an elective operation for the closure of patent ductus arteriosus, a 4 French urinary catheter was inserted into an ELBW baby boy for urine output monitoring and left in-situ. Resistance was encountered in attempt to remove the urinary catheter. Abdominal X Ray confirmed intra-vesical knotting of the tube. Knot unravelling by interventional radiology was attempted but was unsuccessful. Open extra-peritoneal bladder exploration was performed for the retrieval of the tightly knotted catheter. A 6 French transurethral Foley catheter was inserted for bladder drainage. Upon removal of the Foley's catheter on day 5 post op, the baby was able to void spontaneously. With literature review, we postulated the potential risk factors resulting in this potentially avoidable iatrogenic unusual complication. Recommendations were suggested to avoid further incidences.

  18. Stabilization of a percutaneously implanted port catheter system for hepatic artery chemotherapy infusion

    International Nuclear Information System (INIS)

    Shindoh, Noboru; Ozaki, Yutaka; Kyogoku, Shinsuke; Yamana, Daigo; Sumi, Yukiharu; Katayama, Hitoshi

    1999-01-01

    A port catheter system for hepatic artery infusion chemotherapy was implanted percutaneously via the left subclavian artery in 41 patients for treatment of unresectable liver metastases. The catheter tip was inserted into the gastroduodenal artery (GDA), the end hole was occluded with a guidewire fragment, and a side-hole for infusion was positioned at the bifurcation of the proper hepatic artery and the GDA. The GDA was embolized with steel coils around the infusion catheter tip via a transfemoral catheter. This procedure is designed to reduce the incidence of hepatic artery occlusion and infusion catheter dislocation.

  19. Advantages and disadvantages of peripherally inserted central venous catheters (PICC) compared to other central venous lines: a systematic review of the literature.

    Science.gov (United States)

    Johansson, Eva; Hammarskjöld, Fredrik; Lundberg, Dag; Arnlind, Marianne Heibert

    2013-06-01

    The use of central venous lines carries a significant risk for serious complications and high economic costs. Lately, the peripherally inserted central venous catheter (PICC) has gained in popularity due to presumed advantages over other central venous lines. The aim of this systematic literature review was to identify scientific evidence justifying the use of PICC. The literature review was performed according to the principles of Cochrane Collaboration. The electronic literature search included common databases up to March 2011. Only those studies rated as high or moderate quality were used for grading of evidence and conclusions. The search resulted in 827 abstracts, 48 articles were read in full text, and 11 met the inclusion criteria. None of the articles was classified as high quality and two had moderate quality. The results of these two studies indicate that PICC increases the risk for deep venous thrombosis (DVT), but decreases the risk for catheter occlusion. The quality of scientific evidence behind these conclusions, however, was limited. Due to the lack of studies with sufficiently high quality, questions such as early complications, patient satisfaction and costs could not be answered. We conclude that although PICCs are frequently used in oncology, scientific evidence supporting any advantage or disadvantage of PICC when comparing PICC with traditional central venous lines is limited, apart from a tendency towards increased risk for DVT and a decreased risk for catheter occlusion with PICC.

  20. Usefulness of a Biliary Manipulation Catheter in Percutaneous Transhepatic Biliary Drainage

    Energy Technology Data Exchange (ETDEWEB)

    Paek, Auh Whan [Dept. of Radiology, Virginia University Heath Center, Charlottesville (United States); Won, Je Hwan; Lee, Jei Hee; Sun, Joo Sung; Kwak, Kyu Sung; Bae, Jae Ik [Dept. of Radiology, Ajou University School of Medicine, Suwon (Korea, Republic of)

    2011-04-15

    To evaluate usefulness of a manipulation catheter in percutaneous transhepatic biliary drainage (PTBD). A biliary manipulation catheter was used for the aspiration of retained bile and lesion crossing during an initial PTBD in 91 consecutive patients over a 6 month period. This catheter allowed for a 0.035 inch guide wire made of 5F short steel braided polyurethane. The terminal 1 cm segment was tapered and 45 degree angulated. Two side holes were made in the terminal segment to facilitate the aspiration of bile. The safety of this procedure was evaluated based on whether the catheters caused complications during insertion and manipulation, and whether cholangitis was aggravated after the procedure. Effectiveness of the procedure was evaluated based on the ability to aspirate retained bile and to cross the lesion. Both the insertion of a 0.035 inch hydrophilic guide wire and aspiration of sufficient retained bile were successful with the catheter. Crossing the common bile duct (CBD) lesion had a 98.1% success rate during the initial PTBD. Crossing the hilar obstruction lesion was had a 94.7% success rate to the CBD and 92.1% to the contralateral lobe. Cholangitis improved in 97% of cases, and aggravated transiently in only 3% of cases after PTBD.

  1. Usefulness of a Biliary Manipulation Catheter in Percutaneous Transhepatic Biliary Drainage

    International Nuclear Information System (INIS)

    Paek, Auh Whan; Won, Je Hwan; Lee, Jei Hee; Sun, Joo Sung; Kwak, Kyu Sung; Bae, Jae Ik

    2011-01-01

    To evaluate usefulness of a manipulation catheter in percutaneous transhepatic biliary drainage (PTBD). A biliary manipulation catheter was used for the aspiration of retained bile and lesion crossing during an initial PTBD in 91 consecutive patients over a 6 month period. This catheter allowed for a 0.035 inch guide wire made of 5F short steel braided polyurethane. The terminal 1 cm segment was tapered and 45 degree angulated. Two side holes were made in the terminal segment to facilitate the aspiration of bile. The safety of this procedure was evaluated based on whether the catheters caused complications during insertion and manipulation, and whether cholangitis was aggravated after the procedure. Effectiveness of the procedure was evaluated based on the ability to aspirate retained bile and to cross the lesion. Both the insertion of a 0.035 inch hydrophilic guide wire and aspiration of sufficient retained bile were successful with the catheter. Crossing the common bile duct (CBD) lesion had a 98.1% success rate during the initial PTBD. Crossing the hilar obstruction lesion was had a 94.7% success rate to the CBD and 92.1% to the contralateral lobe. Cholangitis improved in 97% of cases, and aggravated transiently in only 3% of cases after PTBD.

  2. Peripheral intravenous catheter-related phlebitis and related risk factors.

    Science.gov (United States)

    Nassaji-Zavareh, M; Ghorbani, R

    2007-08-01

    Peripheral intravenous catheter-related phlebitis is a common and significant problem in clinical practice. This study aims to investigate the incidence of phlebitis and to evaluate some important related factors. 300 patients admitted to medical and surgical wards of hospitals in Semnan, Iran from April 2003 to February 2004 were prospectively studied. Variables evaluated were age, gender, site and size of catheter, type of insertion and underlying conditions (diabetes mellitus, trauma, infectious disease and burns). Phlebitis was defined when at least four criteria were fulfilled (erythema, pain, tenderness, warmth, induration, palpable cord and swelling). Any patient who was discharged or their catheter removed before three days were excluded. Phlebitis occurred in 26 percent (95 percent confidence interval [CI] 21- 31 percent) of patients. There was no significant relationship between age, catheter bore size, trauma and phlebitis. Related risk factors were gender (odds-ratio [OR] 1.50, 95 percent CI 1.01-2.22), site (OR 3.25, 95 percent CI 2.26-4.67) and type of insertion (OR 2.04, 95 percent CI 1.36-3.05) of catheter, diabetes mellitus (OR 7.78, 95 percent CI 4.59-13.21), infectious disease (OR 6.21, 95 percent CI 4.27-9.03) and burns (OR 3.96, 95 percent CI 3.26-4.82). Phlebitis is still an important and ongoing problem in medical practice. In patients with diabetes mellitus and infectious diseases, more attention is needed.

  3. Missed signs of autonomic dysreflexia in a tetraplegic patient after incorrect placement of urethral Foley catheter: a case report.

    Science.gov (United States)

    Vaidyanathan, Subramanian; Soni, Bakul M; Oo, Tun; Hughes, Peter L; Singh, Gurpreet

    2014-01-01

    Autonomic dysreflexia is poorly recognised outside of spinal cord injury centres, and may result in adverse outcomes including mortality from delayed diagnosis and treatment. We present a spinal cord injury patient, who developed autonomic dysreflexia following incorrect placement of urethral Foley catheter. Health professionals failed to recognise signs and symptoms of autonomic dysreflexia as well as its significance in this tetraplegic patient. A tetraplegic patient started sweating profusely following insertion of a Foley catheter per urethra. The catheter was draining urine; there was no bypassing, no bleeding per urethra, and no haematuria. Patient's wife, who had been looking after her tetraplegic husband for more than forty years, told the health professionals that the catheter might have been placed incorrectly but her concerns were ignored. Ultrasound scan of urinary tract revealed no urinary calculi, no hydronephrosis. The balloon of Foley catheter was not seen in urinary bladder but this finding was not recognised by radiologist and spinal cord physician. Patient continued to sweat profusely; therefore, CT of pelvis was performed, but there was a delay of ten days. CT revealed the balloon of Foley catheter in the over-stretched prostate-membranous urethra; the tip of catheter was not located within the urinary bladder but was lying distal to bladder neck. Flexible cystoscopy was performed and Foley catheter was inserted into the bladder over a guide wire. The intensity of sweating decreased; noxious stimuli arising from traumatised urethra might take a long while to settle. Inserting a catheter in a tetraplegic patient should be carried out by a senior health professional, who is familiar with spasm of bladder neck which occurs frequently in tetraplegic patients. Facilities for urgent CT scan should be available to check the position of Foley catheter in spinal cord injury patients when a patient manifests signs and symptoms of autonomic dysreflexia

  4. Rare malposition following left jugular vein catheterization: Case reports and a literature review.

    Science.gov (United States)

    Wang, Lin; Liu, Zhangsuo; Wang, Changan; Liu, Dongwei; Yuan, Yiqiang

    2015-01-01

    The number of patients requiring chronic hemodialysis via a tunneled cuffed catheter is increasing. The right internal jugular vein (IJV) is generally the preferred site of percutaneous insertion. In certain situations, for example, in patients with a history of multiple access failures, catheterization of the left IJV is an important option. In this report, we present two rare cases of catheter malposition after left IJV catheterization; catheter adjustments, with the help of chest radiographs, resulted in a positive outcome in both cases. These cases exemplify the difficulties associated with left IJV catheterization, of which there are few reports in the published literature.

  5. Value of modified Foley catheter method in the removal of blunt esophageal foreign bodies

    International Nuclear Information System (INIS)

    Kim, Kyung In; Cha, Yoo Mi; Han, Heon; Yang, Dal Mo; Kim, Hyung Sik; Lee, Young Seok

    1993-01-01

    Removal of blunt esophageal foreign bodies using Foley catheter under a fluoroscopic guidance is a well recognized procedure. However, since this procedure is rather cumbersome and uncomfortable to the patient, the authors tried to find an easier and more convenient modified technique. For 10 patients with esophageal foreign body, we tried the method to the patient who is lying in the right lateral decubitus position and 3 assistants hold head, arms, trunk and legs of the patient without tilting the table and without using immobilizer. Foley catheter is inserted through nostril, nasal cavity and pharynx to esophagus. in order to identify the Foley catheter in esophagus, 0.025 inch short wire was inserted in the Foley catheter. The balloon of a Foley catheter was inflated by 10 cc of air, and the syringe was kept attached to the Foley catheter during the procedure. After passage of the foreign body through the upper esophageal sphinter, the balloon was deflated immediately and the foreign body was removed through the mouth. We successfully removed in removing all the blunt esophageal foreign body with ease. This modified method is also fast, safe and efficient

  6. Bloodstream infection rates in outpatient hemodialysis facilities participating in a collaborative prevention effort: a quality improvement report.

    Science.gov (United States)

    Patel, Priti R; Yi, Sarah H; Booth, Stephanie; Bren, Virginia; Downham, Gemma; Hess, Sally; Kelley, Karen; Lincoln, Mary; Morrissette, Kathy; Lindberg, Curt; Jernigan, John A; Kallen, Alexander J

    2013-08-01

    Bloodstream infections (BSIs) cause substantial morbidity in hemodialysis patients. In 2009, the US Centers for Disease Control and Prevention (CDC) sponsored a collaborative project to prevent BSIs in outpatient hemodialysis facilities. We sought to assess the impact of a set of interventions on BSI and access-related BSI rates in participating facilities using data reported to the CDC's National Healthcare Safety Network (NHSN). Quality improvement project. Patients in 17 outpatient hemodialysis facilities that volunteered to participate. Facilities reported monthly event and denominator data to NHSN, received guidance from the CDC, and implemented an evidence-based intervention package that included chlorhexidine use for catheter exit-site care, staff training and competency assessments focused on catheter care and aseptic technique, hand hygiene and vascular access care audits, and feedback of infection and adherence rates to staff. Crude and modeled BSI and access-related BSI rates. Up to 12 months of preintervention (January 2009 through December 2009) and 15 months of intervention period (January 2010 through March 2011) data from participating centers were analyzed. Segmented regression analysis was used to assess changes in BSI and access-related BSI rates during the preintervention and intervention periods. Most (65%) participating facilities were hospital based. Pooled mean BSI and access-related BSI rates were 1.09 and 0.73 events per 100 patient-months during the preintervention period and 0.89 and 0.42 events per 100 patient-months during the intervention period, respectively. Modeled rates decreased 32% (P = 0.01) for BSIs and 54% (P facilities were not representative of all outpatient hemodialysis centers nationally. There was no control arm to this quality improvement project. Facilities participating in a collaborative successfully decreased their BSI and access-related BSI rates. The decreased rates appeared to be maintained in the intervention

  7. [Assertiveness and peripheral intravenous catheters dwell time with ultrasonography-guided insertion in children and adolescents].

    Science.gov (United States)

    Avelar, Ariane Ferreira Machado; Peterlini, Maria Angélica Sorgini; da Pedreira, Mavilde Luz Gonçalves

    2013-06-01

    Randomized controlled trial which aimed to verify whether the use of vascular ultrasound (VUS) increases assertiveness in the use of peripheral venous catheter in children, and the catheter dwell time, when compared to traditional puncture. Data were collected after approval of theethical merit. Children and adolescents undergoing VUS-guided peripheral intravenous (GVUS) or puncture guided by clinical assessment of the venous conditions(CG) were included in the study. Significance level was set at pAssertiveness was found in 73 (71.6%) GVUS catheters and in 84(71.8%) of the CG (p=0.970), and catheter dwell time presented a median of less than one day in both groups (p=0.121), showing nostatistically significant difference. VUS did not significantly influence the results of the dependent variables investigated. ClinicalTrials.govNCT00930254.

  8. The Effect of Model Fidelity on Learning Outcomes of a Simulation-Based Education Program for Central Venous Catheter Insertion.

    Science.gov (United States)

    Diederich, Emily; Mahnken, Jonathan D; Rigler, Sally K; Williamson, Timothy L; Tarver, Stephen; Sharpe, Matthew R

    2015-12-01

    Simulation-based education for central venous catheter (CVC) insertion has been repeatedly documented to improve performance, but the impact of simulation model fidelity has not been described. The aim of this study was to examine the impact of the physical fidelity of the simulation model on learning outcomes for a simulation-based education program for CVC insertion. Forty consecutive residents rotating through the medical intensive care unit of an academic medical center completed a simulation-based education program for CVC insertion. The curriculum was designed in accordance with the principles of deliberate practice and mastery learning. Each resident underwent baseline skills testing and was then randomized to training on a commercially available CVC model with high physical fidelity (High-Fi group) or a simply constructed model with low physical fidelity (Low-Fi group) in a noninferiority trial. Upon completion of their medical intensive care unit rotation 4 weeks later, residents returned for repeat skills testing on the high-fidelity model using a 26-item checklist. The mean (SD) posttraining score on the 26-item checklist for the Low-Fi group was 23.8 (2.2) (91.5%) and was not inferior to the mean (SD) score for the High-Fi group of 22.5 (2.6) (86.5%) (P Simulation-based education using equipment with low physical fidelity can achieve learning outcomes comparable with those with high-fidelity equipment, as long as other aspects of fidelity are maintained and robust educational principles are applied during the design of the curriculum.

  9. Severe upper extremity polyneuropathy due to inferior brachial plexus compression as a result of left subclavian artery pseudoaneurism

    Directory of Open Access Journals (Sweden)

    George Kosmadakis

    2012-01-01

    Full Text Available In the present report, we describe the case of a 76-year-old hemodialysis patient who was admitted with clinical features of neurological thoracic exit syndrome due to subclavian artery pseudoaneurism following the insertion of a dual lumen vascular internal jugular catheter (vascath with excellent outcome after endo-arterial stent placement.

  10. Simulation-based medical education training improves short and long-term competency in, and knowledge of central venous catheter insertion: A before and after intervention study.

    Science.gov (United States)

    Cartier, Vanessa; Inan, Cigdem; Zingg, Walter; Delhumeau, Cecile; Walder, Bernard; Savoldelli, Georges L

    2016-08-01

    Multimodal educational interventions have been shown to improve short-term competency in, and knowledge of central venous catheter (CVC) insertion. To evaluate the effectiveness of simulation-based medical education training in improving short and long-term competency in, and knowledge of CVC insertion. Before and after intervention study. University Geneva Hospital, Geneva, Switzerland, between May 2008 and January 2012. Residents in anaesthesiology aware of the Seldinger technique for vascular puncture. Participants attended a half-day course on CVC insertion. Learning objectives included work organization, aseptic technique and prevention of CVC complications. CVC insertion competency was tested pretraining, posttraining and then more than 2 years after training (sustainability phase). The primary study outcome was competency as measured by a global rating scale of technical skills, a hand hygiene compliance score and a checklist compliance score. Secondary outcome was knowledge as measured by a standardised pretraining and posttraining multiple-choice questionnaire. Statistical analyses were performed using paired Student's t test or Wilcoxon signed-rank test. Thirty-seven residents were included; 18 were tested in the sustainability phase (on average 34 months after training). The average global rating of skills was 23.4 points (±SD 4.08) before training, 32.2 (±4.51) after training (P Simulation-based medical education training was effective in improving short and long-term competency in, and knowledge of CVC insertion.

  11. Vascular access choice in incident hemodialysis patients: a decision analysis.

    Science.gov (United States)

    Drew, David A; Lok, Charmaine E; Cohen, Joshua T; Wagner, Martin; Tangri, Navdeep; Weiner, Daniel E

    2015-01-01

    Hemodialysis vascular access recommendations promote arteriovenous (AV) fistulas first; however, it may not be the best approach for all hemodialysis patients, because likelihood of successful fistula placement, procedure-related and subsequent costs, and patient survival modify the optimal access choice. We performed a decision analysis evaluating AV fistula, AV graft, and central venous catheter (CVC) strategies for patients initiating hemodialysis with a CVC, a scenario occurring in over 70% of United States dialysis patients. A decision tree model was constructed to reflect progression from hemodialysis initiation. Patients were classified into one of three vascular access choices: maintain CVC, attempt fistula, or attempt graft. We explicitly modeled probabilities of primary and secondary patency for each access type, with success modified by age, sex, and diabetes. Access-specific mortality was incorporated using preexisting cohort data, including terms for age, sex, and diabetes. Costs were ascertained from the 2010 USRDS report and Medicare for procedure costs. An AV fistula attempt strategy was found to be superior to AV grafts and CVCs in regard to mortality and cost for the majority of patient characteristic combinations, especially younger men without diabetes. Women with diabetes and elderly men with diabetes had similar outcomes, regardless of access type. Overall, the advantages of an AV fistula attempt strategy lessened considerably among older patients, particularly women with diabetes, reflecting the effect of lower AV fistula success rates and lower life expectancy. These results suggest that vascular access-related outcomes may be optimized by considering individual patient characteristics. Copyright © 2015 by the American Society of Nephrology.

  12. Phlebitis and infiltration: vascular trauma associated with the peripheral venous catheter

    Science.gov (United States)

    Braga, Luciene Muniz; Parreira, Pedro Miguel; Oliveira, Anabela de Sousa Salgueiro; Mónico, Lisete dos Santos Mendes; Arreguy-Sena, Cristina; Henriques, Maria Adriana

    2018-01-01

    ABSTRACT Objective: to determine the incidence rate and risk factors for the nursing-sensitive indicators phlebitis and infiltration in patients with peripheral venous catheters (PVCs). Method: cohort study with 110 patients. Scales were used to assess and document phlebitis and infiltration. Socio-demographic variables, clinical variables related to the PVC, medication and hospitalization variables were collected. Descriptive and inferential analysis and multivariate logistic models were used. Results: the incidence rate of phlebitis and infiltration was respectively 43.2 and 59.7 per 1000 catheter-days. Most PVCs with these vascular traumas were removed in the first 24 hours. Risk factors for phlebitis were: length of hospital stay (p=0.042) and number of catheters inserted (p<0.001); risk factors for infiltration were: piperacillin/tazobactan (p=0.024) and the number of catheters inserted (p<0.001). Conclusion: the investigation documented the incidence of nursing-sensitive indicators (phlebitis and infiltration) and revealed new risk factors related to infiltration. It also allowed a reflection on the nursing care necessary to prevent these vascular traumas and on the indications and contraindications of the PVC, supporting the implementation of the PICC as an alternative to PVC. PMID:29791668

  13. Postprocedural Aspiration Test to Predict Adequacy of Dialysis Following Tunneled Catheter Placement

    International Nuclear Information System (INIS)

    Smith, Jason C.; Sullivan, Kevin L.; Michael, Beckie

    2006-01-01

    The objective of the study was to determine if a timed aspiration technique with a 20-ml syringe can be used to predict adequacy of blood flow in tunneled dialysis catheters. Sixteen patients referred for de novo placement or manipulation of failing tunneled hemodialysis catheters had the time it takes to fill a 20-ml syringe with the plunger fully withdrawn measured to the nearest tenth of a second. These measurements were correlated with flow rates recorded in dialysis just prior to (if failed catheter) and in the following dialysis session with adequacy determined as at least 300 ml/min. Syringe-filling time (22 catheters in 16 patients) was plotted against adequacy of dialysis. The mean time to fill a 20-ml syringe was 2.2 sec, with a range of 1.0-4.7 sec. The mean time to fill syringes for catheters with adequate dialysis was 1.7 ± 0.5 sec, and for inadequate catheters, it was 2.8 ± 0.8 sec. These differences are statistically significant (p < 0.001). Using a filling time of greater than or equal to 2 sec as a threshold gives the highest sensitivity (100%) for predicting inadequate dialysis while maintaining high specificity (75%). To achieve a specificity of 100%, a 3-sec cutoff would be necessary, but would lead to a sensitivity of only 20%. A simple and objective aspiration technique can be performed at the time of tunneled dialysis catheter placement/manipulation to reasonably predict adequacy of subsequent dialysis

  14. Image-guided chemoport insertion by interventional radiologists: A single-center experience on periprocedural complications

    International Nuclear Information System (INIS)

    Yaacob, Yazmin; Nguyen, Dang V; Mohamed, Zahiah; Ralib, A Razali A; Zakaria, Rozman; Muda, Sobri

    2013-01-01

    To report our early experience in image-guided chemoport insertions by interventional radiologists. This was a cross-sectional study conducted in a tertiary center with 161 chemoport insertions done from June 2008 to June 2010. The chemoports were inserted either at the angiography suite or at the mobile operation theater unit. Ninety percent of the chemoports had right internal jugular vein (IJV) as the entry site. Other entry sites included the left IJV, subclavian veins and the inferior vena cava. Immediate and early complications were recorded. All insertions were performed under image guidance with the aid of ultrasound and fluoroscopy. The technical success rate was 99.4%. In terms of immediate complications, there were only two cases of arterial puncture that resolved with local compression. No pneumothorax or air embolism was documented. Twenty-six early complications were recorded. The most common early complication was catheter blockage (12/161; 7.4%), followed by catheter-related infection (9/161; 5.6%). Other complications were catheter malposition, venous thrombosis and catheter dislodgement or leak. A total of 11 (6.8%) chemoports had to be removed within 30 days; most of them were due to infections that failed to respond to systemic antibiotic therapy. In terms of place of procedure, there were no significant differences in complication rates between the angiography suite and the mobile operation theater unit. Image-guided chemoport insertion by interventional radiologist gives low periprocedural complication rates. Using right IJV as the entry site, the image guidance gives good success rate with least complication

  15. Radiologic placement of tunneled central catheters: rates of success and of immediate complications in a large series.

    Science.gov (United States)

    Docktor, B L; Sadler, D J; Gray, R R; Saliken, J C; So, C B

    1999-08-01

    The objective was to examine the success and immediate complication rates in a large series of radiologically placed tunneled central venous catheters. We prospectively recorded the success and immediate complication rates in 880 consecutive radiologically placed tunneled central venous catheters. We also recorded the indication for placement, the success of placement, the number of passes required, and whether a double- or single-wall puncture occurred. Hemodialysis was the most common indication for long-term venous access. Venous access was successful in all patients, and catheter placement was successful in 99.4% of patients, with only five failed placements. All patients in whom placement was initially unsuccessful underwent successful placement the same day. All catheters were placed using real-time sonographic guidance. Most were placed in an internal jugular vein, with 87.4% requiring only a single needle pass. The immediate complication rate was only 4.0%, and no major complications occurred. To our knowledge, this series is the largest for which the immediate complication and success rates for radiologically placed central venous catheters have been reported. Our results suggest that radiologic placement of tunneled central venous catheters is a safe and effective alternative to surgery.

  16. Hemodialysis-related headache.

    Science.gov (United States)

    Sav, Murat Yusuf; Sav, Tansu; Senocak, Elif; Sav, Nadide Melike

    2014-10-01

    Headache is one of the most frequently encountered neurological symptoms during hemodialysis. According to International Classification of Headache criteria dialysis-related headache was defined as the headache occurring during hemodialysis with no specific characteristic. It resolves spontaneously within 72 hours after the hemodialysis session ends. There are few studies in the literature investigating the clinical features of dialysis headache. The pathophysiology of hemodialysis-related headache is not known, but various triggering factors have been identified, including changes in blood pressure, serum sodium and magnesium levels during hemodialysis sessions, caffeine deprivation and stress. The aim of this article is to evaluate and analyze features of headache in patients undergoing hemodialysis. © 2014 International Society for Hemodialysis.

  17. The effect of self-selected soothing music on fistula puncture-related pain in hemodialysis patients.

    Science.gov (United States)

    Shabandokht-Zarmi, Hosniyeh; Bagheri-Nesami, Masoumeh; Shorofi, Seyed Afshin; Mousavinasab, Seyed Nouraddin

    2017-11-01

    This study was intended to examine the effect of selective soothing music on fistula puncture-related pain in hemodialysis patients. This is a randomized clinical trial in which 114 participants were selected from two hemodialysis units by means of a non-random, convenience sampling method. The participants were then allocated in three groups of music (N = 38), headphone (N = 38), and control (N = 38). The fistula puncture-related pain was measured 1 min after venipuncture procedure in all three groups. The music group listened to their self-selected and preferred music 6 min before needle insertion into a fistula until the end of procedure. The headphone group wore a headphone alone without listening to music 6 min before needle insertion into a fistula until the end of procedure. The control group did not receive any intervention from the research team during needle insertion into a fistula. The pain intensity was measured immediately after the intervention in all three groups. This study showed a significant difference between the music and control groups, and the music and headphone groups in terms of the mean pain score after the intervention. However, the analysis did not indicate any significant difference between the headphone and control groups with regard to the mean pain score after the intervention. It is concluded that music can be used effectively for pain related to needle insertion into a fistula in hemodialysis patients. Future research should investigate the comparative effects of pharmacological and non-pharmacological interventions on fistula puncture-related pain. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Bloodstream infection in patients with end-stage renal disease in a teaching hospital in central-western Brazil

    Directory of Open Access Journals (Sweden)

    Tamara Trelha Gauna

    2013-08-01

    Full Text Available Introduction Vascular access in patients undergoing hemodialysis is considered a critical determinant of bloodstream infection (BSI and is associated with high morbidity and mortality. The purpose of this study was to investigate the occurrence of BSI in patients with end-stage renal disease using central venous catheters for hemodialysis. Methods A cohort study was conducted in a public teaching hospital in central-western Brazil from April 2010 to December 2011. For every patient, we noted the presence of hyperemia/exudation upon catheter insertion, as well as fever, shivering, and chills during hemodialysis. Results Fifty-nine patients were evaluated. Thirty-five (59.3% patients started dialysis due to urgency, 37 (62.7% had BSI, and 12 (20% died. Hyperemia at the catheter insertion site (64.9% was a significant clinical manifestation in patients with BSI. Statistical analysis revealed 1.7 times more cases of BSI in patients with hypoalbuminemia compared with patients with normal albumin levels. The principal infective agents identified in blood cultures and catheter-tip cultures were Staphylococcus species (24 cases, non-fermentative Gram-negative bacilli (7 cases of Stenotrophomonas maltophilia and 5 cases of Chryseobacterium indologenes, and Candida species (6. Among the Staphylococci identified, 77.7% were methicillin-resistant, coagulase-negative Staphylococci. Of the bacteria isolated, the most resistant were Chryseobacterium indologenes and Acinetobacter baumannii. Conclusions Blood culture was demonstrated to be an important diagnostic test and identified over 50% of positive BSI cases. The high frequency of BSI and the isolation of multiresistant bacteria were disturbing findings. Staphylococcus aureus was the most frequently isolated microorganism, although Gram-negative bacteria predominated overall. These results highlight the importance of infection prevention and control measures in dialysis units.

  19. Central Venous Catheter-Related Bloodstream Infection with Kocuria kristinae in a Patient with Propionic Acidemia.

    Science.gov (United States)

    Kimura, Masato; Kawai, Eichiro; Yaoita, Hisao; Ichinoi, Natsuko; Sakamoto, Osamu; Kure, Shigeo

    2017-01-01

    Kocuria kristinae is a catalase-positive, coagulase-negative, Gram-positive coccus found in the environment and in normal skin and mucosa in humans; however, it is rarely isolated from clinical specimens and is considered a nonpathogenic bacterium. We describe a case of catheter-related bacteremia due to K. kristinae in a young adult with propionic acidemia undergoing periodic hemodialysis. The patient had a central venous catheter implanted for total parenteral nutrition approximately 6 months prior to the onset of symptoms because of repeated acute pancreatitis. K. kristinae was isolated from two sets of blood cultures collected from the catheter. Vancomycin followed by cefazolin for 16 days and 5-day ethanol lock therapy successfully eradicated the K. kristinae bacteremia. Although human infections with this organism appear to be rare and are sometimes considered to result from contamination, physicians should not underestimate its significance when it is isolated in clinical specimens.

  20. Femoral venous catheters: a safe alternative for delivering parenteral alimentation.

    Science.gov (United States)

    Friedman, B; Kanter, G; Titus, D

    1994-04-01

    Femoral vein catheterization is an alternative method of obtaining central venous access. Placement of femoral venous catheters (FVCs) is possible in the majority of patients, suitable for most indications, and associated with a low complication rate during insertion. We wished to determine the incidence of infections or other complications resulting when parenteral nutrition was delivered through FVCs. Fifty-two patients were followed from a hospital-wide population including patients in the critical care units. Triple-lumen catheters were placed by using the sterile Seldinger technique, and sites were examined daily for inflammation. Bacteriologic surveillance was accomplished by submitting the catheter tip for semiquantitative cultures. If catheter line sepsis was suspected, blood samples for cultures were drawn through the catheter and peripherally. The rate of occurrence of colonized catheters was 9.6% (five of 52), and catheter sepsis was found in one case (1.9%). Other than inflammation at six (11.5%) of 52 catheter sites, noninfectious complications of FVCs were not found. On the basis of these findings, we consider FVC-delivered parenteral alimentation a safe and effective alternative to other forms of central venous access.

  1. [Catheter-associated bloodstream infections: implementation of a new consensus protocol].

    Science.gov (United States)

    Urrea Ayala, M; Rozas Quesada, L

    2009-07-01

    Catheter-associated bloodstream infection is highly prevalent and often associated with fatal complications. Some studies have shown that applying preventive interventions could help to reduce and control this type of infection. To determine whether a new consensus protocol for the manipulation and maintenance of central venous catheters would decrease catheter-associated bloodstream infections (CA-BSIs) in paediatric patients. To evaluate its compliance in intensive care units. Prospective study in the paediatric (PICU) and neonatal (NICU) intensive cares units, haematology, oncology and hospital wards in a Maternal and Paediatric reference Hospital in Barcelona. The study period is divided into two periods: before (first semester) and after the start of the new protocol (second semester) in 2007. The most important changes have been the insertion of the hermetic connection in the proximal and distal site (between the line and the syringe) of the central venous catheter (CVC), the labelling of the medication line and the CVC with the date of placement. A check-list to evaluate compliance was introduced in both intensive care units (paediatrics and neonatal) during the second study period. The rates of bloodstream infection per 1000 catheter-days were assessed. The rate of bloodstream infections per 1000 catheter-days before and after the start of the new protocol was 5.7 and 4.9 in PICU; 24.6 and 18.0 in NICU; 7.6 and 4.6 in haematology-oncology, and 11.9 and 10.3 in hospital wards. As regards compliance to the protocol, we found that proximal sealed connectors were used in more than 95% of the cases and up to 85% of the central venous catheter were labelled with the insertion date in both intensive care units. A consensus protocol for the use and maintenance of central venous catheters and healthcare worker training helped to control the rate of CA-BSIs. We reaffirm the importance of epidemiological surveillance as a measure for controlling nosocomial infections.

  2. Improving Nurses' Peripheral Intravenous Catheter Insertion Knowledge, Confidence, and Skills Using a Simulation-Based Blended Learning Program: A Randomized Trial.

    Science.gov (United States)

    Keleekai, Nowai L; Schuster, Catherine A; Murray, Connie L; King, Mary Anne; Stahl, Brian R; Labrozzi, Laura J; Gallucci, Susan; LeClair, Matthew W; Glover, Kevin R

    2016-12-01

    Peripheral intravenous catheter (PIVC) insertion is one of the most common invasive procedures performed in a hospital, but most nurses receive little formal training in this area. Blended PIVC insertion training programs that incorporate deliberate simulated practice have the potential to improve clinical practice and patient care. The study was a randomized, wait-list control group with crossover using nurses on three medical/surgical units. Baseline PIVC knowledge, confidence, and skills assessments were completed for both groups. The intervention group then received a 2-hour PIVC online course, followed by an 8-hour live training course using a synergistic mix of three simulation tools. Both groups were then reassessed. After crossover, the wait-list group received the same intervention and both groups were reassessed. At baseline, both groups were similar for knowledge, confidence, and skills. Compared with the wait-list group, the intervention group had significantly higher scores for knowledge, confidence, and skills upon completing the training program. After crossover, the wait-list group had similarly higher scores for knowledge, confidence, and skills than the intervention group. Between the immediate preintervention and postintervention periods, the intervention group improved scores for knowledge by 31%, skills by 24%, and decreased confidence by 0.5%, whereas the wait-list group improved scores for knowledge by 28%, confidence by 16%, and skills by 15%. Results demonstrate significant improvements in nurses' knowledge, confidence, and skills with the use of a simulation-based blended learning program for PIVC insertion. Transferability of these findings from a simulated environment into clinical practice should be further explored.

  3. Cutting-balloon angioplasty of resistant ureteral stenosis as bridge to stent insertion

    Energy Technology Data Exchange (ETDEWEB)

    Iezzi, R., E-mail: iezzir@virgilio.it [Department of Bioimaging and Radiological Sciences, Institute of Radiology, ' A. Gemelli' Hospital - Catholic University, L.go A Gemelli 8, 00168 Rome (Italy); Di Stasi, C.; Simeone, A.; Bonomo, L. [Department of Bioimaging and Radiological Sciences, Institute of Radiology, ' A. Gemelli' Hospital - Catholic University, L.go A Gemelli 8, 00168 Rome (Italy)

    2011-07-15

    Ureteral stenting is a routine, minimally invasive procedure performed for relief of benign or malignant obstruction. In case of ureteral stenosis, to allow a correct insertion of the stent, a predilatation of the ureter stenosis with a conventional balloon catheter can be necessary. In exceptional cases, it can be difficult to advance an 7-8 Fr JJ-catheter over a tight resistant ureter stenosis following unsuccessful high-pressure balloon dilatation. In the present report, we describe two cases of resistant ureter stenosis successfully dilated by a cutting-balloon following the failure of high-pressure balloon dilatation, allowing a correct and uncomplicated antegrade stent insertion.

  4. Cutting-balloon angioplasty of resistant ureteral stenosis as bridge to stent insertion

    International Nuclear Information System (INIS)

    Iezzi, R.; Di Stasi, C.; Simeone, A.; Bonomo, L.

    2011-01-01

    Ureteral stenting is a routine, minimally invasive procedure performed for relief of benign or malignant obstruction. In case of ureteral stenosis, to allow a correct insertion of the stent, a predilatation of the ureter stenosis with a conventional balloon catheter can be necessary. In exceptional cases, it can be difficult to advance an 7-8 Fr JJ-catheter over a tight resistant ureter stenosis following unsuccessful high-pressure balloon dilatation. In the present report, we describe two cases of resistant ureter stenosis successfully dilated by a cutting-balloon following the failure of high-pressure balloon dilatation, allowing a correct and uncomplicated antegrade stent insertion.

  5. Flow Rate Through Pigtail Catheter Used for Left Heart Decompression in an Artificial Model of Extracorporeal Membrane Oxygenation Circuit.

    Science.gov (United States)

    Kim, Won Ho; Hong, Tae Hee; Byun, Joung Hun; Kim, Jong Woo; Kim, Sung Hwan; Moon, Sung Ho; Park, Hyun Oh; Choi, Jun Young; Yang, Jun Ho; Jang, In Seok; Lee, Chung Eun; Yun, Jeong Hee

    In refractory cardiogenic shock, veno-arterial extracorporeal membrane oxygenation (ECMO) can be initiated. Although left heart decompression can be accomplished by insertion of a left atrial (LA) or left ventricular (LV) cannula using a percutaneous pigtail catheter, the venting flow rate according to catheter size and ECMO flow rate is unknown. We developed an artificial ECMO circuit. One liter saline bag with its pressure set to 20 mm Hg was connected to ECMO to mimic LV failure. A pigtail catheter was inserted into the 1 L saline bag to simulate LV unloading. For each pigtail catheter size (5-8 Fr) and ECMO flow rate (2.0-4.0 L/min), the moving distance of an air bubble that was injected through a three-way stopcock was measured in the arterial pressure line between the pigtail catheter and ECMO inflow limb. The flow rate was then calculated. We obtained the following equation to estimate the pigtail catheter flow rate.Pigtail vent catheter flow rate (ml/min) = 8×ECMOflow rate(L /min)+9×pigtail catheter size(Fr)- 57This equation would aid in designing of a further study to determine optimal venting flow rate. To achieve optimal venting flow, our equation would enable selection of an adequate catheter size.

  6. Central Venous Catheter-Related Bloodstream Infection with Kocuria kristinae in a Patient with Propionic Acidemia

    Directory of Open Access Journals (Sweden)

    Masato Kimura

    2017-01-01

    Full Text Available Kocuria kristinae is a catalase-positive, coagulase-negative, Gram-positive coccus found in the environment and in normal skin and mucosa in humans; however, it is rarely isolated from clinical specimens and is considered a nonpathogenic bacterium. We describe a case of catheter-related bacteremia due to K. kristinae in a young adult with propionic acidemia undergoing periodic hemodialysis. The patient had a central venous catheter implanted for total parenteral nutrition approximately 6 months prior to the onset of symptoms because of repeated acute pancreatitis. K. kristinae was isolated from two sets of blood cultures collected from the catheter. Vancomycin followed by cefazolin for 16 days and 5-day ethanol lock therapy successfully eradicated the K. kristinae bacteremia. Although human infections with this organism appear to be rare and are sometimes considered to result from contamination, physicians should not underestimate its significance when it is isolated in clinical specimens.

  7. A simple method of using a Foley catheter to drain pleural effusion.

    Science.gov (United States)

    Ben-Nun, Alon; Best, Lael Anson

    2008-01-01

    Pleural effusion is a common problem, and various techniques of pleural fluid drainage have been described. We report our experience of using a Foley-type catheter to drain pleural effusion. After the injection of local anesthesia, the catheter is inserted, usually through the 7th intercostal space, with the patient sitting upright. The size of the catheter is selected according to the predicted fluid characteristics, and ranges from 18 to 24 F. Once the catheter is positioned in the pleural space, the balloon is inflated with diluted soluble contrast material and connected to a urine collection bag. During the last 10 years, we have used 3500 catheters for this purpose. The catheter site can be used as a port for various procedures, including needle biopsy of the parietal pleura, talc-slurry pleurodesis, and intra-pleural fibrinolysis. This method of pleural drainage is simple, reliable, and inexpensive.

  8. A chronic hemodialysis patient with isolated pulmonary valve infective endocarditis caused by non-albicans Candida: a rare case and literature review.

    Science.gov (United States)

    Chang, Chih-Hao; Huang, Myo-Ming; Yeih, Dong-Feng; Lu, Kuo-Cheng; Hou, Yi-Chou

    2017-09-06

    Isolated pulmonary valve infective endocarditis caused by Candida is rare in chronic hemodialysis patients. The 2009 Infectious Diseases Society of America guidelines suggest the combined use of surgery and antibiotics to treat candidiasis; however, successful nonsurgical treatment of Candida endocarditis has been reported. A 63-year-old woman with end-stage kidney disease was admitted to our hospital after experiencing disorientation for 5 days. The patient was permanently bedridden because of depression, and denied active intravenous drug use. She received maintenance hemodialysis through a tunneled-cuffed catheter. An initial blood culture grew Candida guilliermondii without other bacteria. Subsequent blood cultures and tip culture of tunneled-cuffed catheter also grew C. guilliermondii, even after caspofungin replaced fluconazole. A 1.2-cm mobile mass was observed on the pulmonary valve. Surgical intervention was suggested, but the family of the patient declined because of her multiple comorbidities. The patient was discharged with a prescription of fluconazole, but she died soon after. Our patient is the first case with isolated pulmonary valve endocarditis caused by C. guilliermondii in patients with uremia. Hematologic disorders, in addition to long-term central venous catheter use, prolonged antibiotic intravenous injection, and congenital cardiac anomaly, predispose to the condition. The diagnosis "isolated" pulmonary IE is difficult, and combing surgery with antifungal antibiotics is the appropriate therapeutic management for Candida related pulmonary IE.

  9. Virtual 5-French intra-aortic pumping using a Glidesheath Slender and 6-French intra-aortic balloon catheter

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Akihiko, E-mail: a-takahashi@wine.ocn.ne.jp; Taniguchi, Norimasa; Mizuguchi, Yukio; Yamada, Takeshi; Nakajima, Shunsuke; Hashimoto, Sho; Hata, Tetsuya

    2015-07-15

    Objectives: The aim of this study was to evaluate the feasibility and safety of the 6-Fr Glidesheath Slender, which has equivalent outer size to the conventional 5-Fr sheath, for use with the 6-Fr intra-aortic balloon pump (IABP) catheter. Methods: Between May 2014 and March 2015, 24 patients with acute coronary syndrome underwent percutaneous coronary intervention using a 6-Fr IABP catheter through a 6-Fr Glidesheath Slender for support. The adverse events, including access site complications, kinking of the sheath during the procedure, and any evidence of balloon pump failure, were retrospectively investigated. Results: Insertion of the IABP catheter through either the femoral or brachial artery was successful in all patients. The mean support time was 32.4 ± 22.0 h. No major hemorrhagic event or severe limb ischemia was observed. Kinking of the shaft occurred during insertion in one patient; however, the subsequent balloon pumping was well maintained and did not require exchange of the sheath or IABP catheter. No kind of IABP failure was observed. Conclusion: Although this sheath was originally designed to allow radial access, our results suggest that the use of the Glidesheath Slender is feasible for insertion of the 6-Fr IABP catheter through the brachial and femoral arteries, and may reduce vascular complications in patients who undergo percutaneous coronary intervention.

  10. Displacement of popliteal sciatic nerve catheters after major foot and ankle surgery: a randomized controlled double-blinded magnetic resonance imaging study

    DEFF Research Database (Denmark)

    Hauritz, R W; Pedersen, E M; Linde, F S

    2016-01-01

    Popliteal sciatic nerve catheters (PSNCs) are associated with a high frequency of displacement. We aimed to estimate the frequency of catheter displacement after 48 h with magnetic resonance imaging (MRI) in patients with PSNCs after major foot and ankle surgery randomized to catheter insertion e...

  11. Percutaneous catheter drainage of lung abscess

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Shin; Chun, Kyung Ah; Choi, Hyo Sun; Ha, Hyun Kown; Shinn, Kyung Sub [Catholic University Medical college, Seoul (Korea, Republic of)

    1993-09-15

    From March 1987 to July 1989, six patients (five adults and one child) with lung abscess (size, 5-13 cm in diameter) were treated with percutaneous aspiration and drainage. In each case, the puncture was made where the wall of the abscess was in contact with the pleural surface. An 8 to 10 Fr cartheter was inserted for drainage. Five of 6 had a dynamatic clinical response within 24 hours of the drainage. Percutaneous drainage was successful with complete abscess resolution in four and partial resolution in one patient. No response was seen in the rest one. The duration of drainage ranged from 7 to 18 days(average, 15.5 days) in successful cases. One case of the failure in drainage was due tio persistent aspiration of the neurologically impaired patient. In one patient, the abscess resolved after drainage but recurred after inadvertent removal of the catheter 7 days after insertion. In two patients, concurrent pleural empyema was resolved completely by the drainage. Computed tomography provide anatomic details necessary for choosing the puncture site and avoiding a puncture of the lung parenchyma. Percutaneous catheter drainage is safe and effective method for treating patient with lung abscess.

  12. Percutaneous catheter drainage of lung abscess

    International Nuclear Information System (INIS)

    Kim, Young Shin; Chun, Kyung Ah; Choi, Hyo Sun; Ha, Hyun Kown; Shinn, Kyung Sub

    1993-01-01

    From March 1987 to July 1989, six patients (five adults and one child) with lung abscess (size, 5-13 cm in diameter) were treated with percutaneous aspiration and drainage. In each case, the puncture was made where the wall of the abscess was in contact with the pleural surface. An 8 to 10 Fr cartheter was inserted for drainage. Five of 6 had a dynamatic clinical response within 24 hours of the drainage. Percutaneous drainage was successful with complete abscess resolution in four and partial resolution in one patient. No response was seen in the rest one. The duration of drainage ranged from 7 to 18 days(average, 15.5 days) in successful cases. One case of the failure in drainage was due tio persistent aspiration of the neurologically impaired patient. In one patient, the abscess resolved after drainage but recurred after inadvertent removal of the catheter 7 days after insertion. In two patients, concurrent pleural empyema was resolved completely by the drainage. Computed tomography provide anatomic details necessary for choosing the puncture site and avoiding a puncture of the lung parenchyma. Percutaneous catheter drainage is safe and effective method for treating patient with lung abscess

  13. Hemodialysis in a patient with severe hemophilia A and factor VIII inhibitor.

    Science.gov (United States)

    Gopalakrishnan, Natarajan; Usha, Thiruvengadam; Thopalan, Balasubramaniyan; Dhanapriya, Jeyachandran; Dineshkumar, Thanigachalam; Thirumalvalavan, Kaliaperumal; Sakthirajan, Ramanathan

    2016-10-01

    Hemophilia A is a hereditary X-linked recessive disease caused by mutations in the gene encoding factor VIII (FVIII), occurring in 1 out of 10,000 persons. Life expectancy and quality of life have dramatically improved recently in patients with hemophilia. Chronic kidney disease and need for renal replacement therapy in these patients are rare. The development of inhibitors to FVIII is the most serious complication of hemophilia and makes treatment of bleeds very challenging. We describe here a 28-year-old male patient with severe hemophilia A with presence of factor VIII inhibitor, who had end stage renal disease. Central venous access device was inserted along with infusion of factor eight inhibitor bypass activity before and after the procedure. He is currently on thrice weekly hemodialysis and doing well for 6 months without bleeding episodes. To our knowledge, hemophilia A with factor VIII inhibitor managed with hemodialysis has not been reported so far. © 2016 International Society for Hemodialysis.

  14. Definite Infective Endocarditis: Clinical and Microbiological Features of 155 Episodes in One Japanese University Hospital

    Directory of Open Access Journals (Sweden)

    Yoko Takayama

    2010-11-01

    Conclusion: The most frequently isolated pathogens were viridans group streptococci, which differed from other recent studies. In the present study, no penicillin-resistant strains were detected and there was a higher mortality rate for IE caused by MRSA than MSSA. IE should be considered in MRSA patients with the following risk factors: nosocomial infection, hemodialysis, and surgery or intravascular catheter insertion.

  15. Choice of Hemodialysis Access in Older Adults: A Cost-Effectiveness Analysis.

    Science.gov (United States)

    Hall, Rasheeda K; Myers, Evan R; Rosas, Sylvia E; O'Hare, Ann M; Colón-Emeric, Cathleen S

    2017-06-07

    Although arteriovenous fistulas have been found to be the most cost-effective form of hemodialysis access, the relative benefits of placing an arteriovenous fistula versus an arteriovenous graft seem to be least certain for older adults and when placed preemptively. However, older adults' life expectancy is heterogeneous, and most patients do not undergo permanent access creation until after dialysis initiation. We evaluated cost-effectiveness of arteriovenous fistula placement after dialysis initiation in older adults as a function of age and life expectancy. Using a hypothetical cohort of patients on incident hemodialysis with central venous catheters, we constructed Markov models of three treatment options: ( 1 ) arteriovenous fistula placement, ( 2 ) arteriovenous graft placement, or ( 3 ) continued catheter use. Costs, utilities, and transitional probabilities were derived from existing literature. Probabilistic sensitivity analyses were performed by age group (65-69, 70-74, 75-79, 80-84, and 85-89 years old) and quartile of life expectancy. Costs, quality-adjusted life-months, and incremental cost-effectiveness ratios were evaluated for up to 5 years. The arteriovenous fistula option was cost effective compared with continued catheter use for all age and life expectancy groups, except for 85-89 year olds in the lowest life expectancy quartile. The arteriovenous fistula option was more cost effective than the arteriovenous graft option for all quartiles of life expectancy among the 65- to 69-year-old age group. For older age groups, differences in cost-effectiveness between the strategies were attenuated, and the arteriovenous fistula option tended to only be cost effective in patients with life expectancy >2 years. For groups for which the arteriovenous fistula option was not cost saving, the cost to gain one quality-adjusted life-month ranged from $2294 to $14,042. Among older adults, the cost-effectiveness of an arteriovenous fistula placed within the first

  16. Placement of central venous port catheters and peripherally inserted central catheters in the routine clinical setting of a radiology department: analysis of costs and intervention duration learning curve.

    Science.gov (United States)

    Rotzinger, Roman; Gebauer, Bernhard; Schnapauff, Dirk; Streitparth, Florian; Wieners, Gero; Grieser, Christian; Freyhardt, Patrick; Hamm, Bernd; Maurer, Martin H

    2017-12-01

    Background Placement of central venous port catheters (CVPS) and peripherally inserted central catheters (PICC) is an integral component of state-of-the-art patient care. In the era of increasing cost awareness, it is desirable to have more information to comprehensively assess both procedures. Purpose To perform a retrospective analysis of interventional radiologic implantation of CVPS and PICC lines in a large patient population including a cost analysis of both methods as well as an investigation the learning curve in terms of the interventions' durations. Material and Methods All CVPS and PICC line related interventions performed in an interventional radiology department during a three-year period from January 2011 to December 2013 were examined. Documented patient data included sex, venous access site, and indication for CVPS or PICC placement. A cost analysis including intervention times was performed based on the prorated costs of equipment use, staff costs, and expenditures for disposables. The decrease in intervention duration in the course of time conformed to the learning curve. Results In total, 2987 interventions were performed by 16 radiologists: 1777 CVPS and 791 PICC lines. An average implantation took 22.5 ± 0.6 min (CVPS) and 10.1 ± 0.9 min (PICC lines). For CVPS, this average time was achieved by seven radiologists newly learning the procedures after performing 20 CVPS implantations. Total costs per implantation were €242 (CVPS) and €201 (PICC lines). Conclusion Interventional radiologic implantations of CVPS and PICC lines are well-established procedures, easy to learn by residents, and can be implanted at low costs.

  17. Sex-specific differences in hemodialysis prevalence and practices and the male-to-female mortality rate: the Dialysis Outcomes and Practice Patterns Study (DOPPS.

    Directory of Open Access Journals (Sweden)

    Manfred Hecking

    2014-10-01

    Full Text Available BACKGROUND: A comprehensive analysis of sex-specific differences in the characteristics, treatment, and outcomes of individuals with end-stage renal disease undergoing dialysis might reveal treatment inequalities and targets to improve sex-specific patient care. Here we describe hemodialysis prevalence and patient characteristics by sex, compare the adult male-to-female mortality rate with data from the general population, and evaluate sex interactions with mortality. METHODS AND FINDINGS: We assessed the Human Mortality Database and 206,374 patients receiving hemodialysis from 12 countries (Australia, Belgium, Canada, France, Germany, Italy, Japan, New Zealand, Spain, Sweden, the UK, and the US participating in the international, prospective Dialysis Outcomes and Practice Patterns Study (DOPPS between June 1996 and March 2012. Among 35,964 sampled DOPPS patients with full data collection, we studied patient characteristics (descriptively and mortality (via Cox regression by sex. In all age groups, more men than women were on hemodialysis (59% versus 41% overall, with large differences observed between countries. The average estimated glomerular filtration rate at hemodialysis initiation was higher in men than women. The male-to-female mortality rate ratio in the general population varied from 1.5 to 2.6 for age groups <75 y, but in hemodialysis patients was close to one. Compared to women, men were younger (mean = 61.9 ± standard deviation 14.6 versus 63.1 ± 14.5 y, were less frequently obese, were more frequently married and recipients of a kidney transplant, more frequently had coronary artery disease, and were less frequently depressed. Interaction analyses showed that the mortality risk associated with several comorbidities and hemodialysis catheter use was lower for men (hazard ratio [HR] = 1.11 than women (HR = 1.33, interaction p<0.001. This study is limited by its inability to establish causality for the observed sex

  18. 2016 Expert consensus document on prevention, diagnosis and treatment of short-term peripheral venous catheter-related infections in adults

    Directory of Open Access Journals (Sweden)

    Josep A. Capdevila

    2016-07-01

    Full Text Available The use of endovascular catheters is a routine practice in secondary and tertiary care level hospitals. The short-term use of peripheral catheters has been found to be associated with the risk of nosocomial bacteraemia, resulting in morbidity and mortality. Staphylococcus aureus is mostly associated with peripheral catheter insertion. This Consensus Document has been prepared by a panel of experts of the Spanish Society of Cardiovascular Infections, in cooperation with experts from the Spanish Society of Internal Medicine, Spanish Society of Chemotherapy, and the Spanish Society of Thoracic-Cardiovascular Surgery, and aims to define and establish guidelines for the management of short duration peripheral vascular catheters. The document addresses the indications for insertion, catheter maintenance, registering, diagnosis and treatment of infection, indications for removal, as well as placing an emphasis on continuous education as a drive toward quality. Implementation of these guidelines will allow uniformity in use, thus minimizing the risk of infections and their complications.

  19. Comparing the Efficacy and Side Effects of Trans-Cervical Catheter and Vaginal Misoprostol on Cervical Ripening

    Directory of Open Access Journals (Sweden)

    F. Mallah

    2016-08-01

    Full Text Available Background: The success of labor induction is extremely dependent on the state of the cervix. There are various methods available in modern obstetrics practice for ripening the cervix, such as intravaginal prostaglandins and mechanical devices like transcervical catheters. Although plenty of studies have already compared the two methods for the unripened cervices, more studies are warranted in nulliparous patients only. This study aimed to compare the efficacy of intravaginal misoprostol tablets with transcervical Foley catheter for cervical ripening in nulliparous patients. Methods & Materials: In this randomized clinical trial, 120 nulliparous candidates for labor induction were recruited from two teaching centers in Tabriz within a 17-month period of time. All the enrolled cases had a live singleton fetus with cephalic presentation at term (≥37 weeks, on-admission Bishop Score≤4, intact membranes and reactive non-stress test results. They were randomly assigned to two equal age-matched groups receiving either intravaginal misoprostol (25 microgram, n=59, or transcervical insertion of 16F Foley catheter (n=60. Results: One time successful induction (i.e. successful induction after a single insertion of misoprostol, or expulsion of transcervical Foley catheter within 12 h of insertion was achieved in all the patients without employment of other methods such as use of syntocinon. Misoprostol was more effective in terms of induction-to-cervical ripening interval (15.16±3.59 h vs. 18.30±1.59 h; p<0.001. Tachysystole, on the other hand, was significantly more frequent in the misoprostol receivers (25.4% vs. 0%; p<0.001. The two groups were comparable for the rate of cesarean section (misoprostol, 37.3%; Folly catheter, 30%; p=0.40. Comparing the two groups, there was no significant difference with regard to change in Bishop Score (misoprostol, 1.90±0.54 h-1; Folly catheter, 1.89±0.74 h-1; p=0.95 and miscellaneous pregnancy-related and fetal

  20. Isolated Calyx Mistaken for a Cyst: Inappropriately Performed Catheter-Directed Sclerotherapy and Safe Removal of the Catheter After Selective Embolization

    Energy Technology Data Exchange (ETDEWEB)

    Gwak, Jng Won, E-mail: jjungwonie@hanmail.net; Lee, Seung Hwa, E-mail: gareureung@daum.net; Chung, Hwan Hoon, E-mail: chungmic@korea.ac.kr; Je, Bo Kyung, E-mail: purity21@hanmail.net; Yeom, Suk kyu, E-mail: pagoda20@hanmail.net [Korea University College of Medicine, Department of Radiology, Ansan Hospital (Korea, Republic of); Sung, Deuk Jae, E-mail: urora@korea.ac.kr [Korea University College of Medicine, Department of Radiology, Anam Hospital (Korea, Republic of)

    2015-02-15

    We present a case of isolated calyx that was mistaken for a large cyst. A 47-year-old woman was referred for sclerotherapy of a large cystic lesion on her left kidney. Computed tomography (CT) and ultrasound showed that the cystic lesion was a large cyst. We noticed that the cystic lesion was not a typical simple cyst, even after two sessions of catheter-mediated sclerotherapy. Isolated calyx was presumed by medical history review and was confirmed by aspirated fluid analysis and far delayed-phase CT after intravenous contrast injection. We performed meticulous selective arterial embolization for an isolated calyx and inserted a catheter that could be removed without complication.

  1. Percutaneous placement of peritoneal port-catheter in oncologic patients

    International Nuclear Information System (INIS)

    Orsi, Franco; Vigna, Paolo Della; Bonomo, Guido; Penco, Silvia; Lovati, Elena; Bellomi, Massimo

    2004-01-01

    The aim of this paper is to describe the technique of percutaneous ultrasound (US)-guided placement of a peritoneal port-catheter in an interventional radiological setting. Nineteen patients with peritoneal carcinomatosis were selected for intraperitoneal port-catheter placement in order to perform intracavitary receptor-immuno- or radio-immunotherapy with Ytrium-90. All the procedures were performed percutaneously under US and fluoro guidance; the insertion site for catheters was chosen according to abdominal conditions and US findings: all devices were implanted at the lower abdominal quadrants. All patients were followed up with CT and US according to the therapy protocol. The procedure was successfully completed in 15/19 patients, in 4 being contraindicated by peritoneal adhesions. No procedure-related complications and device occlusions during therapy were observed; one catheter displaced 7 months later the placement. In our experience, this procedure was feasible, reliable and easy to perform, allowing the correct administration of the planned intracavitary therapy. Peritoneal adhesions are the main limitation of peritoneal port placement. (orig.)

  2. Ultrasound Pulsed-Wave Doppler Detects an Intrathecal Location of an Epidural Catheter Tip: A Case Report.

    Science.gov (United States)

    Elsharkawy, Hesham; Saasouh, Wael; Patel, Bimal; Babazade, Rovnat

    2018-04-01

    Currently, no gold standard method exists for localization of an epidural catheter after placement. The technique described in this report uses pulsed-wave Doppler (PWD) ultrasound to identify intrathecal location of an epidural catheter. A thoracic epidural catheter was inserted after multiple trials with inconclusive aspiration and test dose. Ultrasound PWD confirmed no flow in the epidural space and positive flow in the intrathecal space. A fluid aspirate was positive for glucose, reconfirming intrathecal placement. PWD is a potential tool that can be used to locate the tip of an epidural catheter.

  3. Acute Urinary Obstruction in a Tetraplegic Patient from Misplacement of Catheter in Urethra.

    Science.gov (United States)

    Vaidyanathan, Subramanian; Singh, Gurpreet; Hughes, Peter L; Soni, Bakul M

    2016-01-01

    A male tetraplegic patient attended accident and emergency with a blocked catheter; on removing the catheter, he passed bloody urine. After three unsuccessful attempts were made to insert a catheter by nursing staff, a junior doctor inserted a three-way Foley catheter with a 30-mL balloon but inflated the balloon with 10 mL of water to commence the bladder irrigation. The creatinine level was mostly 19 µmol/L (range: 0-135 µmol/L) but increased to 46 µmol/L on day 7. Computerized tomography urogram revealed that the bilateral hydronephrosis with hydroureter was extended down to urinary bladder, the bladder was distended, prostatic urethra was dilated and filled with urine, and although the balloon of Foley catheter was not seen in the bladder, the tip of the catheter was seen lying in the urethra. Following the re-catheterization, the creatinine level decreased to 21 µmol/L. A follow-up ultrasound scan revealed no evidence of hydronephrosis in both kidneys. Flexible cystoscopy revealed inflamed bladder mucosa, catheter reaction, and tiny stones. There was no bladder tumor. This case report concludes that the cause of bilateral hydronephrosis, hydroureter, and distended bladder was inadequate drainage of urinary bladder as the Foley balloon that was under-filled slipped into the urethra resulting in an obstruction to urine flow. Urethral catheterization in tetraplegic patients should be performed by senior, experienced staff in order to avoid trauma and incorrect positioning. Tetraplegic subjects with decreased muscle mass have low creatinine level. Increase in creatinine level (>1.5 times the basal level) indicates acute kidney injury, although peak creatinine level may still be within laboratory reference range. While scanning the urinary tract of spinal cord injury patients with indwelling urinary catheter, if Foley balloon is not seen within the bladder, urethra should be scanned to locate the Foley balloon.

  4. CENTRAL VENOUS CATHETER AS A VASCULAR APPROACH TO HEMODIALYSTS

    Directory of Open Access Journals (Sweden)

    Verica Djordjevic

    2001-03-01

    Full Text Available The application of the central venous catheter (CVC as a temporary orpermanent vascular approach to hemodialysis has been practiced in our Center since1994. So far 30 (12,6% patients have been thus treated. The primary application hasbeen done in 25 patients, namely: the first making of the A V fistula has been done in16, the ABT in 6, while the vascular approach correction in 3 patients. The secondaryapplication has been done in 5 patients. The infection episode incidence concerningthe CVC application is 20 infections per 1.000 patients. This is the upper limitaccording to the data given in the literature (5, rang 3-20. The average duration of thecatheter is 21 + - 13 days (rang 1-47. Two-volume catheters have been used for ajugular approach though less often for a femoral one. The unsuccessful placing due tothe catheter thrombosis has occurred in 4 patients, the catheter drop-out and itsreplacing have been done in 2 patients, while no replacement has happened in onečaše. The treatment has been stopped in one patient. Tn four patients the cerebrovascularinsult has happened after placing the CVC. The mortality rate is 26,6%,that is, K patients, namely: 4 due to cerebrovascular insult, one due to lung emboly,one due to heart weakness and one due to the sepsis from the V fistula. One patientdied at home for unknown reason. A high infection episode incidence rate is related toinadequate patients' placing so that their location in the rooms for intensive care is away of reducing it. It is necessary to provide for general aseptic procedure at work aswell as for betterment of the accompanying procedures (hemoculture, antibiograms,sterilization in order to maintain a safe catheter function.

  5. An epidural catheter removal after recent percutaneous coronary intervention and coronary artery stenting: Epidural catheter and antiaggregation therapy

    Directory of Open Access Journals (Sweden)

    Joksić Nikola

    2016-01-01

    Full Text Available Introduction: Anticoagulation and antiplatelet therapy in the presence of the epidural catheter is still controversial. It is well known that dual antiplatelet therapy is indicated for 12 months after the placement of drug-eluting stents (DES. Removal of an epidural catheter during that period is related to an increased risk of stent occlusion in case of discontinuation of platelet function inhibitors or, on the other hand, increased risk of epidural hematoma associated with neurological deficit if suppressed platelet function is still present. Case Report: Here we present a case of a 63-year-old man who was admitted to Institute for Cardiovascular Diseases Dedinje for elective aortic surgery. Before the induction, an epidural catheter was inserted at the Th10-Th11 epidural space. Uneventful surgery was performed under the combined epidural and general anesthesia. On the 2nd postoperative day, the patient sustained a ST depression myocardial infarction treated with percutaneous coronary intervention with DES placement, while epidural catheter was still in place. Dual antiplatelet therapy with 600mg of clopidogrel, 100 mg of acetilsalicylic acid (ASA and low molecular weight heparin (LMWH were started during the procedure. The next day, clopidogrel (75 mg and ASA (100 mg were continued as well as LMWH. The decision to remove the epidural catheter was made on the 9th postoperative day, after platelet aggregation assays were performed. Six hours after catheter removal the patient again received clopidogrel, ASA and LMWH. There were no signs of epidural hematoma. Conclusion: This case shows that point-of-care testing with platelet aggregation assays may be useful in increasing the margin of safety for epidural catheter removal during dual antiplatelet therapy.

  6. Usefulness of a pleuroperitoneal shunt for treatment of refractory pleural effusion in a patient receiving maintenance hemodialysis.

    Science.gov (United States)

    Habuka, Masato; Ito, Toru; Yoshizawa, Yuta; Matsuo, Koji; Murakami, Shuichi; Kondo, Daisuke; Kanazawa, Hiroshi; Narita, Ichiei

    2018-03-23

    Refractory pleural effusion can be a life-threatening complication in patients receiving maintenance hemodialysis. We report successful treatment of refractory pleural effusion using a Denver® pleuroperitoneal shunt in one such patient. A 54-year-old Japanese man, who had previously undergone left nephrectomy, was admitted urgently to our department because of a high C-reactive protein (CRP) level, right pleural effusion, and right renal abscess. Because antibiotics proved ineffective and his general state was deteriorating, he underwent emergency insertion of a thoracic drainage tube and nephrectomy, and hemodialysis was started. Although his general state improved slowly thereafter, the pleural effusion, which was unilateral and transudative, remained refractory and therefore he needed to be on oxygenation. To control the massive pleural effusion, a pleuroperitoneal shunt was inserted. Thereafter, his respiratory condition became stable without oxygenation and he was discharged. His general condition has since been well. Although pleural effusion is a common complication of maintenance hemodialysis, few reports have documented the use of pleuroperitoneal shunt to control refractory pleural effusion. Pleuroperitoneal shunt has been advocated as an effective and low-morbidity treatment for refractory pleural effusion, and its use for some patients with recurrent pleural effusion has also been reported, without any severe complications. In the present case, pleuroperitoneal shunt improved the patient's quality of life sufficiently to allow him to be discharged home without oxygenation. Pleuroperitoneal shunt should be considered a useful treatment option for hemodialysis patients with refractory pleural effusion.

  7. Tunneled dialysis catheter exchange with fibrin sheath disruption is not associated with increased rate of bacteremia.

    Science.gov (United States)

    Valliant, Amanda M; Chaudhry, Muhammad K; Yevzlin, Alexander S; Astor, Brad; Chan, Micah R

    2015-01-01

    Tunneled dialysis catheters are the most common form of vascular access among incident dialysis patients in the United States. Fibrin sheath formation is a frequent cause of late catheter dysfunction requiring an exchange procedure with balloon disruption of the fibrin sheath. It is unknown whether fibrin sheath disruption is associated with increased incidence of bacteremia or catheter failure. We reviewed all tunneled dialysis catheter exchange procedures at the University of Wisconsin between January 2008 and December 2011. The primary outcome was incidence of bacteremia, defined as positive blood cultures within 2 weeks of the procedure. Catheter failure, requiring intervention or replacement, was examined as a secondary outcome. Baseline characteristics examined included diabetic status, gender, race and age. A total of 163 procedures were reviewed; 67 (41.1%) had fibrin sheath disruption and 96 did not. Bacteremia occurred in 4.5% (3/67) of those with and 3.1% (3/97) of those without fibrin sheath disruption (p=0.65). Fibrin sheath disruption was not significantly associated with the risk of catheter failure (adjusted hazard ratio [aHR]=1.34; 95% confidence interval [CI]: 0.87-2.10; p=0.18). Diabetes was associated with greater risk of catheter failure (aHR=1.88; 95% CI: 1.19-2.95; p=0.006), whereas higher age was associated with a lower risk of catheter failure (aHR per 10 years=0.83; 95% CI: 0.72-0.96; p=0.01). This study demonstrates that there is no significant increase in bacteremia and subsequent catheter dysfunction rates after fibrin sheath disruption compared to simple over the wire exchange. These results are encouraging given the large numbers of patients utilizing tunneled catheters for initial hemodialysis access and the known rates of fibrin sheath formation leading to catheter failure.

  8. Use of Flexible Cystoscopy to Insert a Foley Catheter over a Guide Wire in Spinal Cord Injury Patients: Special Precautions to be Observed.

    Science.gov (United States)

    Vaidyanathan, Subramanian; Soni, Bakul; Singh, Gurpreet; Hughes, Peter; Oo, Tun

    2011-01-01

    When urethral catheterisation is difficult or impossible in spinal cord injury patients, flexible cystoscopy and urethral catheterisation over a guide wire can be performed on the bedside, thus obviating the need for emergency suprapubic cystostomy. Spinal cord injury patients, who undergo flexible cystoscopy and urethral catheterisation over a guide wire, may develop potentially serious complications. (1) Persons with lesion above T-6 are susceptible to develop autonomic dysreflexia during cystoscopy and urethral catheterisation over a guide wire; nifedipine 5-10 milligrams may be administered sublingually just prior to the procedure to prevent autonomic dysreflexia. (2) Spinal cord injury patients are at increased risk for getting urine infections as compared to able-bodied individuals. Therefore, antibiotics should be given to patients who get haematuria or urethral bleeding following urethral catheterisation over a guide wire. (3) Some spinal cord injury patients may have a small capacity bladder; in these patients, the guide wire, which is introduced into the urinary bladder, may fold upon itself with the tip of guide wire entering the urethra. If this complication is not recognised and a catheter is inserted over the guide wire, the Foley catheter will then be misplaced in urethra despite using cystoscopy and guide wire.

  9. Use of Flexible Cystoscopy to Insert a Foley Catheter over a Guide Wire in Spinal Cord Injury Patients: Special Precautions to be Observed

    Directory of Open Access Journals (Sweden)

    Subramanian Vaidyanathan

    2011-01-01

    Full Text Available When urethral catheterisation is difficult or impossible in spinal cord injury patients, flexible cystoscopy and urethral catheterisation over a guide wire can be performed on the bedside, thus obviating the need for emergency suprapubic cystostomy. Spinal cord injury patients, who undergo flexible cystoscopy and urethral catheterisation over a guide wire, may develop potentially serious complications. (1 Persons with lesion above T-6 are susceptible to develop autonomic dysreflexia during cystoscopy and urethral catheterisation over a guide wire; nifedipine 5–10 milligrams may be administered sublingually just prior to the procedure to prevent autonomic dysreflexia. (2 Spinal cord injury patients are at increased risk for getting urine infections as compared to able-bodied individuals. Therefore, antibiotics should be given to patients who get haematuria or urethral bleeding following urethral catheterisation over a guide wire. (3 Some spinal cord injury patients may have a small capacity bladder; in these patients, the guide wire, which is introduced into the urinary bladder, may fold upon itself with the tip of guide wire entering the urethra. If this complication is not recognised and a catheter is inserted over the guide wire, the Foley catheter will then be misplaced in urethra despite using cystoscopy and guide wire.

  10. Increased Intracranial Pressure during Hemodialysis in a Patient with Anoxic Brain Injury

    Directory of Open Access Journals (Sweden)

    Anton Lund

    2017-01-01

    Full Text Available Dialysis disequilibrium syndrome (DDS is a serious neurological complication of hemodialysis, and patients with acute brain injury are at increased risk. We report a case of DDS leading to intracranial hypertension in a patient with anoxic brain injury and discuss the subsequent dialysis strategy. A 13-year-old girl was admitted after prolonged resuscitation from cardiac arrest. Computed tomography (CT revealed an inferior vena cava aneurysm and multiple pulmonary emboli as the likely cause. An intracranial pressure (ICP monitor was inserted, and, on day 3, continuous renal replacement therapy (CRRT was initiated due to acute kidney injury, during which the patient developed severe intracranial hypertension. CT of the brain showed diffuse cerebral edema. CRRT was discontinued, sedation was increased, and hypertonic saline was administered, upon which ICP normalized. Due to persistent hyperkalemia and overhydration, ultrafiltration and intermittent hemodialysis were performed separately on day 4 with a small dialyzer, low blood and dialysate flow, and high dialysate sodium content. During subsequent treatments, isolated ultrafiltration was well tolerated, whereas hemodialysis was associated with increased ICP necessitating frequent pauses or early cessation of dialysis. In patients at risk of DDS, hemodialysis should be performed with utmost care and continuous monitoring of ICP should be considered.

  11. Increased Intracranial Pressure during Hemodialysis in a Patient with Anoxic Brain Injury.

    Science.gov (United States)

    Lund, Anton; Damholt, Mette B; Strange, Ditte G; Kelsen, Jesper; Møller-Sørensen, Hasse; Møller, Kirsten

    2017-01-01

    Dialysis disequilibrium syndrome (DDS) is a serious neurological complication of hemodialysis, and patients with acute brain injury are at increased risk. We report a case of DDS leading to intracranial hypertension in a patient with anoxic brain injury and discuss the subsequent dialysis strategy. A 13-year-old girl was admitted after prolonged resuscitation from cardiac arrest. Computed tomography (CT) revealed an inferior vena cava aneurysm and multiple pulmonary emboli as the likely cause. An intracranial pressure (ICP) monitor was inserted, and, on day 3, continuous renal replacement therapy (CRRT) was initiated due to acute kidney injury, during which the patient developed severe intracranial hypertension. CT of the brain showed diffuse cerebral edema. CRRT was discontinued, sedation was increased, and hypertonic saline was administered, upon which ICP normalized. Due to persistent hyperkalemia and overhydration, ultrafiltration and intermittent hemodialysis were performed separately on day 4 with a small dialyzer, low blood and dialysate flow, and high dialysate sodium content. During subsequent treatments, isolated ultrafiltration was well tolerated, whereas hemodialysis was associated with increased ICP necessitating frequent pauses or early cessation of dialysis. In patients at risk of DDS, hemodialysis should be performed with utmost care and continuous monitoring of ICP should be considered.

  12. Image-guided Ommaya reservoir insertion for intraventricular chemotherapy: a retrospective series.

    Science.gov (United States)

    Lau, Jonathan C; Kosteniuk, Suzanne E; Macdonald, David R; Megyesi, Joseph F

    2018-03-01

    Ayub Ommaya proposed a surgical technique for subcutaneous reservoir and pump placement in 1963 to allow access to intraventricular cerebrospinal fluid (CSF). Currently, the most common indication for Ommaya reservoir insertion (ORI) in adults is for patients with hematologic or leptomeningeal disorders requiring repeated injection of chemotherapy into the CSF space. Historically, the intraventricular catheter has been inserted blindly based on anatomical landmarks. The purpose of this study was to examine short-term complication rates with ORI with image guidance (IG) and without image guidance (non-IG). We retrospectively evaluated all operative cases of ORI from 2000 to 2014 by the senior author. Patient demographic data, surgical outcomes, and peri-operative complications were collected. Accurate placement and early (30-day) morbidity or mortality were considered primary outcomes. Fifty-five consecutive patients underwent ORI by the senior author over the study period (43.5 ± 16.6 years; 40.0% female). Indications for placement included acute lymphoblastic leukemia, diffuse large B-cell lymphoma, and leptomeningeal carcinomatosis. There were seven (12.7%) total complications: three (37.5%) with no-IG versus four (8.5%) with IG. Catheter malpositions were significantly higher in the non-IG group at 37.5% compared to 2.1%. Catheters were also more likely to require multiple passes with non-IG at 25% compare to 0% with IG. There were no early infections in either group. We demonstrate improved accuracy and decreased complications using an image-guided approach compared with a traditional approach. Our results support routine use of intra-operative image guidance for proximal catheter insertion in elective ORI for intraventricular chemotherapy.

  13. Effect of High-Cutoff Hemodialysis vs Conventional Hemodialysis on Hemodialysis Independence Among Patients With Myeloma Cast Nephropathy: A Randomized Clinical Trial.

    Science.gov (United States)

    Bridoux, Frank; Carron, Pierre-Louis; Pegourie, Brigitte; Alamartine, Eric; Augeul-Meunier, Karine; Karras, Alexandre; Joly, Bertrand; Peraldi, Marie-Noëlle; Arnulf, Bertrand; Vigneau, Cécile; Lamy, Thierry; Wynckel, Alain; Kolb, Brigitte; Royer, Bruno; Rabot, Nolwenn; Benboubker, Lotfi; Combe, Christian; Jaccard, Arnaud; Moulin, Bruno; Knebelmann, Bertrand; Chevret, Sylvie; Fermand, Jean-Paul

    2017-12-05

    Cast nephropathy is the main cause of acute kidney injury in multiple myeloma and persistent reduction in kidney function strongly affects prognosis. Strategies to rapidly remove nephrotoxic serum-free light chains combined with novel antimyeloma agents have not been evaluated prospectively. To compare the hemodialysis independence rate among patients newly diagnosed with myeloma cast nephropathy treated with hemodialysis using a high-cutoff dialyzer (with very large membrane pores and high permeability to immunoglobulin light chains) or a conventional high-flux dialyzer (with small pores and lower permeability). Randomized clinical trial involving 98 patients with biopsy-proven myeloma cast nephropathy requiring hemodialysis treated at 48 French centers between July 2011 and June 2016; the final date of follow-up was June 29, 2016. Intensive hemodialysis (eight 5-hour sessions over 10 days) with either a high-cutoff dialyzer (46 patients) or a conventional high-flux dialyzer (48 patients). All patients received the same chemotherapy regimen of bortezomib and dexamethasone. Primary end point was hemodialysis independence at 3 months; secondary end points: hemodialysis independence rates at 6 and 12 months, hemodialysis- and chemotherapy-related adverse events, and death. Among 98 randomized patients, 94 (96%) (median age, 68.8 years [interquartile range, 61.2-75.3 years]; 45% women) were included in the modified intent-to-treat analysis. The hemodialysis independence rate at 3 months was 41.3% (n = 19) in the high-cutoff hemodialysis group vs 33.3% (n = 16) in the conventional hemodialysis group (between-group difference, 8.0% [95% CI, -12.0% to 27.9%], P = .42); at 6 months, the rate was 56.5% (n = 26) vs 35.4% (n = 17), respectively (between-group difference, 21.1% [95% CI, 0.9% to 41.3%], P = .04); and at 12 months, the rate was 60.9% (n = 28) vs 37.5% (n = 18) (between-group difference, 23.4% [95% CI, 3.2% to 43.5%], P = .02

  14. Emergent Start Peritoneal Dialysis for End-Stage Renal Disease: Outcomes and Advantages.

    Science.gov (United States)

    Nayak, K Shivanand; Subhramanyam, Sreepada V; Pavankumar, Navva; Antony, Sinoj; Sarfaraz Khan, M A

    2018-01-01

    Initiating renal replacement therapy in late referred patients with central venous catheter (CVC) hemodialysis (HD) causes serious complications. In urgent start peritoneal dialysis, initiating peritoneal dialysis (PD) within 14 days of catheter insertion still needs HD with CVC. We initiated Emergent start PD (ESPD) with Automated PD (APD) at our center within 48 h from the time of presentation. A prospective, case-controlled, intention-to-treat study with 56 patients was conducted between March 2016 and August 2017. Group A (24 patients) underwent conventional PD 14 days after catheter insertion. Group B (32 patients), underwent ESPD with APD. Exit site leak (ESL), catheter blockage, and peritonitis at 90 days were primary outcomes. Technique survival was secondary outcome. Baseline characteristics were similar with 3 episodes of ESLs (9.4%) in the study group and none in the control group (p = 0.123). Catheter blockage (16.7%-Group A, 25%-Group B) and peritonitis (none vs. 9.4% in study group) were similar in terms of statistical details just as technique survival (95%-Group A, 88.2%-Group B at 90 days). ESPD with APD in the unplanned patient is an appropriate approach. © 2018 S. Karger AG, Basel.

  15. Fibrin Sheath Angioplasty: A Technique to Prevent Superior Vena Cava Stenosis Secondary to Dialysis Catheters

    Science.gov (United States)

    Hacker, Robert I.; Garcia, Lorena De Marco; Chawla, Ankur; Panetta, Thomas F.

    2012-01-01

    Fibrin sheaths are a heterogeneous matrix of cells and debris that form around catheters and are a known cause of central venous stenosis and catheter failure. A total of 50 cases of central venous catheter fibrin sheath angioplasty (FSA) after catheter removal or exchange are presented. A retrospective review of an outpatient office database identified 70 eligible patients over a 19-month period. After informed consent was obtained, the dialysis catheter exiting the skin was clamped, amputated, and a wire was inserted. The catheter was then removed and a 9-French sheath was inserted into the superior vena cava, a venogram was performed. If a fibrin sheath was present, angioplasty was performed using an 8 × 4 or 10 × 4 balloon along the entire length of the fibrin sheath. A completion venogram was performed to document obliteration of the sheath. During the study, 50 patients were diagnosed with a fibrin sheath, and 43 had no pre-existing central venous stenosis. After FSA, 39 of the 43 patient's (91%) central systems remained patent without the need for subsequent interventions; 3 patients (7%) developed subclavian stenoses requiring repeat angioplasty and stenting; 1 patent (2.3%) developed an occlusion requiring a reintervention. Seven patients with prior central stenosis required multiple angioplasties; five required stenting of their central lesions. Every patient had follow-up fistulograms to document long-term patency. We propose that FSA is a prudent and safe procedure that may help reduce the risk of central venous stenosis from fibrin sheaths due to central venous catheters. PMID:23997555

  16. Transposition of cephalic vein to rescue hemodialysis access arteriovenous fistula and treat symptomatic central venous obstruction

    Directory of Open Access Journals (Sweden)

    Felipe Jose Skupien

    2014-03-01

    Full Text Available It is known that stenosis or central venous obstruction affects 20 to 50% of patients who undergo placement of catheters in central veins. For patients who are given hemodialysis via upper limbs, this problem causes debilitating symptoms and increases the risk of loss of hemodialysis access. We report an atypical case of treatment of a dialysis patient with multiple comorbidities, severe swelling and pain in the right upper limb (RUL, few alternative sites for hemodialysis vascular access, a functioning brachiobasilic fistula in the RUL and severe venous hypertension in the same limb, secondary to central vein occlusion of the internal jugular vein and right brachiocephalic trunk. The alternative surgical treatment chosen was to transpose the RUL cephalic vein, forming a venous necklace at the anterior cervical region, bypassing the site of venous occlusion. In order to achieve this, we dissected the cephalic vein in the right arm to its junction with the axillary vein, devalved the cephalic vein and anastomosed it to the contralateral external jugular vein, providing venous drainage to the RUL, alleviating symptoms of venous hypertension and preserving function of the brachiobasilic fistula.

  17. Evaluation of mupirocin ointment in control of central venous catheter related infections: a randomized clinical trial

    Directory of Open Access Journals (Sweden)

    Rezaei J

    2009-09-01

    Full Text Available "n Normal 0 false false false EN-US X-NONE AR-SA MicrosoftInternetExplorer4 st1":*{behavior:url(#ieooui } /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:Arial; mso-bidi-theme-font:minor-bidi;} Background: Central venous catheter (CVC related infections are important complications of cathter application. This study assessed the usefulness of mupirocin in prevention and control of these infections."n"nMethods: In this randomized clinical trial, consecutive surgical patients requiring central venous catheter (for more than 2 days in Amir-Alam Hospital from 2006-2008 were enrolled. Patients were divided in two groups; in "case group" patients received topical mupirocin 2% every 48 hours at the time of insertion of catheter and dressing change and for "control group" mupirocin was not used. All of the patients received chlorhexidine and enoxoparin as complementary treatments. Two groups were comparable in regard of age, sex and risk factors."n"nResults: One hundred eighteen patients enrolled in the study (57 in case and 61 in control group completed the study. 84 catheters in case group and 88 catheters in control group were inserted. The catheters in 90% of patients were inserted in jugular vein. At the end of study 29(16.8% patients (16 in control versus 13 in case group had catheter colonization (p=NS. Catheter related bloodstream infection was observed in 16(9.3% patients (6 in

  18. Anchor balloons assisted deep intubation of 5F catheters for ...

    African Journals Online (AJOL)

    2015-07-24

    Jul 24, 2015 ... However, cardiologists still encounter some difficult scenarios such as variant coronary artery origins, severely calcified and ... Medical University, 300, Guangzhou Road, Nanjing,. Jiangsu .... (l) The ST segment elevated while the 5F catheter was inserted into the proximal left anterior descending artery d.

  19. Ultrasound-guided approach to the paravertebral space for catheter insertion in infants and children.

    Science.gov (United States)

    Boretsky, Karen; Visoiu, Mihaela; Bigeleisen, Paul

    2013-12-01

    Paravertebral perineural blocks are used to prevent pain in the thoracoabdominal dermatomes. Traditionally, a landmark-based technique is used in children, while ultrasound-guided (UG) techniques are being employed in adult patients. To describe an UG technique for placement of thoracic paravertebral nerve block (TPVNB) catheters in pediatric patients. Retrospective chart review of a series of 22 pediatric patients' ages 6 months to 17 years with weights from 6.25 kg to 135 kg using a transverse in-plane technique. Catheters were placed both bilateral and unilateral for a variety of thoracic and abdominal procedures. A linear ultrasound transducer was used in all cases with frequency of oscillation and transducer length chosen based on individual patient characteristics of age, weight, and BMI. The median pain scores at 12, 24, 36, and 48 h were 1.2 (interquartile range, 4.5), 0.84 (interquartile range 3.0), 1.6 (interquartile range 2.9), and 0.83 (interquartile range 1.74), respectively. The median dose of opioid expressed as morphine equivalents consumed during the first 24 h after surgery was 0.14 mg·kg(-1) (interquartile range, 0.78 mg·kg(-1) ) and from 24 to 48 h the median dose was 0.11 mg·kg(-1) (interquartile range 0.44 mg·kg(-1) ). No complications were noted, and catheters were left an average of 3 days with a range of 1-5 days with good pain relief. This technical description demonstrates the feasibility of placing PVNB catheters using a transverse in-line ultrasound-guided technique in a wide range of pediatric patients. © 2013 John Wiley & Sons Ltd.

  20. Prostate HDR brachytherapy catheter displacement between planning and treatment delivery

    International Nuclear Information System (INIS)

    Whitaker, May; Hruby, George; Lovett, Aimee; Patanjali, Nitya

    2011-01-01

    Background and purpose: HDR brachytherapy is used as a conformal boost for treating prostate cancer. Given the large doses delivered, it is critical that the volume treated matches that planned. Our outpatient protocol comprises two 9 Gy fractions, two weeks apart. We prospectively assessed catheter displacement between CT planning and treatment delivery. Materials and methods: Three fiducial markers and the catheters were implanted under transrectal ultrasound guidance. Metal marker wires were inserted into 4 reference catheters before CT; marker positions relative to each other and to the marker wires were measured from the CT scout. Measurements were repeated immediately prior to treatment delivery using pelvic X-ray with marker wires in the same reference catheters. Measurements from CT scout and film were compared. For displacements of 5 mm or more, indexer positions were adjusted prior to treatment delivery. Results: Results are based on 48 implants, in 25 patients. Median time from planning CT to treatment delivery was 254 min (range 81–367 min). Median catheter displacement was 7.5 mm (range −2.9–23.9 mm), 67% of implants had displacement of 5 mm or greater. Displacements were predominantly caudal. Conclusions: Catheter displacement can occur in the 1–3 h between the planning CT scan and treatment. It is recommended that departments performing HDR prostate brachytherapy verify catheter positions immediately prior to treatment delivery.

  1. Number and location of drainage catheter side holes: in vitro evaluation.

    Science.gov (United States)

    Ballard, D H; Alexander, J S; Weisman, J A; Orchard, M A; Williams, J T; D'Agostino, H B

    2015-09-01

    To evaluate the influence of number and location of catheter shaft side holes regarding drainage efficiency in an in vitro model. Three different drainage catheter models were constructed: open-ended model with no side holes (one catheter), unilateral side hole model (six catheters with one to six unilateral side holes), and bilateral side hole model (six catheters with one to six bilateral side holes). Catheters were inserted into a drainage output-measuring device with a constant-pressure reservoir of water. The volume of water evacuated by each of the catheters at 10-second intervals was measured. A total of five trials were performed for each catheter. Data were analysed using one-way analysis of variance. The open-ended catheter had a mean drainage volume comparable to the unilateral model catheters with three, four, and five side holes. Unilateral model catheters had significant drainage volume increases up to three side holes; unilateral model catheters with more than three side holes had no significant improvement in drainage volume. All bilateral model catheters had significantly higher mean drainage volumes than their unilateral counterparts. There was no significant difference between the mean drainage volume with one, two, or three pairs of bilateral side holes. Further, there was no drainage improvement by adding additional bilateral side holes. The present in vitro study suggests that beyond a critical side hole number threshold, adding more distal side holes does not improve catheter drainage efficiency. These results may be used to enhance catheter design towards improving their drainage efficiency. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  2. Physiopathological approach to infective endocarditis in chronic hemodialysis patients: left heart versus right heart involvement.

    Science.gov (United States)

    Bentata, Yassamine

    2017-11-01

    Infectious endocarditis (IE), a complication that is both cardiac and infectious, occurs frequently and is associated with a heavy burden of morbidity and mortality in chronic hemodialysis patients (CHD). About 2-6% of chronic hemodialysis patients develop IE and the incidence is 50-60 times higher among CHD patients than in the general population. The left heart is the most frequent location of IE in CHD and the different published series report a prevalence of left valve involvement varying from 80% to 100%. Valvular and perivalvular abnormalities, alteration of the immune system, and bacteremia associated with repeated manipulation of the vascular access, particularly central venous catheters, comprise the main factors explaining the left heart IE in CHD patients. While left-sided IE develops in altered valves in a high-pressure system, right-sided IE on the contrary, generally develops in healthy valves in a low-pressure system. Right-sided IE is rare, with its incidence varying from 0% to 26% depending on the study, and the tricuspid valve is the main location. Might the massive influx of pathogenic and virulent germs via the central venous catheter to the right heart, with the tricuspid being the first contact valve, have a role in the physiopathology of IE in CHD, thus facilitating bacterial adhesion? While the physiopathology of left-sided IE entails multiple and convincing mechanisms, it is not the case for right-sided IE, for which the physiopathological mechanism is only partially understood and remains shrouded in mystery.

  3. Laparoscopic versus open peritoneal dialysis catheter insertion, the LOCI-trial: A study protocol

    NARCIS (Netherlands)

    S.M. Hagen (Sander); A.M. van Alphen (Adriaan); J.N.M. IJzermans (Jan); F.J.M.F. Dor (Frank)

    2011-01-01

    textabstractBackground: Peritoneal dialysis (PD) is an effective treatment for end-stage renal disease. It allows patients more freedom to perform daily activities compared to haemodialysis. Key to successful PD is the presence of a well-functioning dialysis catheter. Several complications, such as

  4. Minimally Invasive Catheter Procedures to Assist Complicated Pacemaker Lead Extraction and Implantation in the Operating Room

    International Nuclear Information System (INIS)

    Kröpil, Patric; Lanzman, Rotem S.; Miese, Falk R.; Blondin, Dirk; Winter, Joachim; Scherer, Axel; Fürst, Günter

    2011-01-01

    We report on percutaneous catheter procedures in the operating room (OR) to assist complicated manual extraction or insertion of pacemaker (PM) and implantable cardioverter defibrillator leads. We retrospectively reviewed complicated PM revisions and implantations performed between 2004 and 2009 that required percutaneous catheter procedures performed in the OR. The type of interventional procedure, catheter and retrieval system used, venous access, success rates, and procedural complications were analyzed. In 41 (12 female and 29 male [mean age 62 ± 17 years]) of 3021 (1.4%) patients, standard manual retrieval of old leads or insertion of new leads was not achievable and thus required percutaneous catheter intervention for retrieval of misplaced leads and/or recanalisation of occluded central veins. Thirteen of 18 (72.2%) catheter-guided retrieval procedures for misplaced (right atrium [RA] or ventricle [RV; n = 3], superior vena cava [n = 2], brachiocephalic vein [n = 5], and subclavian vein [n = 3]) lead fragments in 16 patients were successful. Percutaneous catheter retrieval failed in five patients because there were extremely fixed or adhered lead fragments. Percutaneous transluminal angiography (PTA) of central veins for occlusion or high-grade stenosis was performed in 25 patients. In 22 of 25 patients (88%), recanalization of central veins was successful, thus enabling subsequent lead replacement. Major periprocedural complications were not observed. In the case of complicated manual PM lead implantation or revision, percutaneous catheter-guided extraction of misplaced lead fragments or recanalisation of central veins can be performed safely in the OR, thus enabling subsequent implantation or revision of PM systems in the majority of patients.

  5. Effects of frequent hemodialysis on perceived caregiver burden in the Frequent Hemodialysis Network trials.

    Science.gov (United States)

    Suri, Rita S; Larive, Brett; Hall, Yoshio; Kimmel, Paul L; Kliger, Alan S; Levin, Nathan; Tamura, Manjula Kurella; Chertow, Glenn M

    2014-05-01

    Patients receiving hemodialysis often perceive their caregivers are overburdened. We hypothesize that increasing hemodialysis frequency would result in higher patient perceptions of burden on their unpaid caregivers. In two separate trials, 245 patients were randomized to receive in-center daily hemodialysis (6 days/week) or conventional hemodialysis (3 days/week) while 87 patients were randomized to receive home nocturnal hemodialysis (6 nights/week) or home conventional hemodialysis for 12 months. Changes in overall mean scores over time in the 10-question Cousineau perceived burden scale were compared. In total, 173 of 245 (70%) and 80 of 87 (92%) randomized patients in the Daily and Nocturnal Trials, respectively, reported having an unpaid caregiver at baseline or during follow-up. Relative to in-center conventional dialysis, the 12-month change in mean perceived burden score with in-center daily hemodialysis was -2.1 (95% confidence interval, -9.4 to +5.3; P=0.58). Relative to home conventional dialysis, the 12-month change in mean perceived burden score with home nocturnal dialysis was +6.1 (95% confidence interval, -0.8 to +13.1; P=0.08). After multiple imputation for missing data in the Nocturnal Trial, the relative difference between home nocturnal and home conventional hemodialysis was +9.4 (95% confidence interval, +0.55 to +18.3; P=0.04). In the Nocturnal Trial, changes in perceived burden were inversely correlated with adherence to dialysis treatments (Pearson r=-0.35; P=0.02). Relative to conventional hemodialysis, in-center daily hemodialysis did not result in higher perceptions of caregiver burden. There was a trend to higher perceived caregiver burden among patients randomized to home nocturnal hemodialysis. These findings may have implications for the adoption of and adherence to frequent nocturnal hemodialysis.

  6. Slow nocturnal home hemodialysis (SNHHD)--one year later.

    Science.gov (United States)

    Ouwendyk, M; Pierratos, A; Francoeur, R; Wallace, L; Sit, W; Vas, S

    1996-01-01

    High costs and overcrowding of dialysis centres are leading to a global crisis in health care provision. We are developing slow nocturnal home hemodialysis (SNHHD) in which patients dialyze for eight to 10 hours during sleep five to seven nights per week. Vascular access is by means of the Cook silastic jugular catheter. Special precautions are taken to prevent accidental disconnection and air embolism. Dialysis functions are remotely monitored on computer via a modem by trained staff. Five patients have completed five to seven weeks of training and have been successfully performing SNHHD single-handedly (three out of five patients live alone) for 14, 14, 11, 10 and four months respectively. All have discontinued their phosphate binders and increased dietary phosphate intake. Compared with conventional hemodialysis (CHD) results, average pre-dialysis urea and creatinine levels are remarkably reduced to 9.6 mmol/l and 486 umol/l respectively. The average cumulative weekly Kt/V for CHD is 5.0 as compared to 7.7 while on SNHHD. Four out of five patients report sleeping soundly and experience greatly increased energy and stamina. Their days are entirely free. Repeated in-situ re-use of the dialyzer and blood lines will reduce the patient's work and make SNHHD a very inexpensive modality. SNHHD appears to be a widely applicable treatment with many advantages to both the patient and the health care system.

  7. Endovascular Treatment of an Iatrogenic Right Internal Jugular Vein- Right Subclavian Artery Fistula and Pseudoaneurysm During the Attempt of a Hemodialysis Catheter Insertion: A Case Report

    International Nuclear Information System (INIS)

    Cho, Eui Min; Kim, Hyun Lee; Kim, Dong Hyun

    2009-01-01

    Complications during the placement of a central venous catheter, via the right internal jugular vein puncture include local hematoma, hemothorax, pneumothorax, central vein thrombosis, and hemopericardium. Iatrogenic right internal jugular vein-right subclavian artery fistula with the formation of right subclavian artery pseudoaneurysms is an extremely rare complication in patients undergoing a central vein puncture. We report the case of a patient who developed a local hematoma at the vein puncture site and dyspnea due to a right internal jugular vein-subclavian artery fistula and a right subclavian artery pseudoaneurysm at the mediastinum after puncture of right internal jugular vein. The patient was successfully treated by embolization using microcoils

  8. The challenge of methicillin-resistant Staphylococcus aureus prevention in hemodialysis therapy.

    Science.gov (United States)

    Parker, Mark G; Doebbeling, Bradley N

    2012-01-01

    Methicillin-resistant Staphylococcus aureus (MRSA) infections have challenged care process and resource utilization in the acute hospital care setting for nearly 30 years. These infections have become important causes of morbidity, mortality, and a source of concern in the primary and emergency care context over the past decade. As individuals receiving recurrent therapy with features of both ambulatory care and acute care, hemodialysis patients are exposed to numerous opportunities for MRSA acquisition. Surprisingly, high prevalence rates for MRSA colonization have been demonstrated for both hemodialysis patients and their care providers. The necessity of vascular access and the persistent high prevalence of endovascular catheter use among patients repeatedly exposed to healthcare settings provide the perfect milieu for the troubling rates of MRSA infection, particularly bloodstream infections, in outpatient dialysis care. Dialysis industry shifts, including increased requirements for compliance and reporting in other areas of dialysis care, tax resources for infection prevention processes. Multifaceted strategies that include reassessment of vascular access care, attention to the interruption of MRSA transmission dynamics, and emphasis on organizational learning processes are needed to accomplish a meaningful reduction in the morbidity, mortality, and cost associated with MRSA infections in dialysis care. © 2011 Wiley Periodicals, Inc.

  9. Fecal containment in bedridden patients: economic impact of 2 commercial bowel catheter systems.

    Science.gov (United States)

    Kowal-Vem, Areta; Poulakidas, Stathis; Barnett, Barbara; Conway, Deborah; Culver, Daniel; Ferrari, Michelle; Potenza, Bruce; Koenig, Michael; Mah, John; Majewski, Mary; Morris, Linda; Powers, Jan; Stokes, Elizabeth; Tan, Michael; Salstrom, Sara-Jane; Zaletel, Cindy; Ambutas, Shirley; Casey, Kathleen; Stein, Jayne; DeSane, Mary; Berry, Kathy; Konz, Elizabeth C; Riemer, Michael R; Cullum, Malford E

    2009-05-01

    Fecal contamination is a major challenge in patients in acute/critical care settings that is associated with increased cost of care and supplies and with development of pressure ulcers, incontinence dermatitis, skin and soft tissue infections, and urinary tract infections. To assess the economic impact of fecal containment in bedridden patients using 2 different indwelling bowel catheters and to compare infection rates between groups. A multicenter, observational study was done at 12 US sites (7 that use catheter A, 5 that use catheter B). Patients were followed from insertion of an indwelling bowel catheter system until the patient left the acute/critical care unit or until 29 days after enrollment, whichever came first. Demographic data, frequency of bedding/dressing changes, incidence of infection, and Braden scores (risk of pressure ulcers) were recorded. The study included 146 bedridden patients (76 with catheter A, 70 with catheter B) who had similar Braden scores at enrollment. The rate of bedding/dressing changes per day differed significantly between groups (1.20 for catheter A vs 1.71 for catheter B; P = .004). According to a formula that accounted for personnel resources and laundry cycle costs, catheter A cost $13.94 less per patient per day to use than did catheter B. Catheter A was less likely than was catheter B to be removed during the observational period (P = .03). Observed infection rates were low. Catheter A may be more cost-effective than catheter B because it requires fewer unscheduled linen changes per patient day.

  10. (Mis)placed central venous catheter in the left superior intercostal vein

    International Nuclear Information System (INIS)

    Padovan, Ranka Stern; Paar, Maja Hrabak; Aurer, Igor

    2010-01-01

    Chest X-ray is routinely performed to check the position of the central venous catheter (CVC) inserted through the internal jugular or subclavian vein, while the further evaluation of CVC malfunction is usually performed by contrast venography. In patients with superior vena cava obstruction, the tip of the catheter is often seen in collateral mediastinal venous pathways, rather than in the superior vena cava. In such cases detailed knowledge of thoracic vessel anatomy is necessary to identify the exact location of the catheter. We report a case of 32-year-old female patient with relapsing mediastinal lymphoma and previous superior vena cava obstruction with collateral azygos-hemiazygos venous pathways. The patient had CVC inserted through the left subclavian vein and its position was detected by CT to be in the dilated left superior intercostal vein and accessory hemiazygos vein. Considering that dilated accessory hemiazygos vein can tolerate infusion, the CVC was left in place and the patient had no complaints related to CVC (mal)position. Furthermore, we present anatomical and radiological observations on the azygos-hemiazygos venous system with the special emphasis on the left superior intercostal vein. Non-contrast CT scans can be a valuable imaging tool in the detection of the CVC position, especially in patients with renal insufficiency and contrast media hypersensitivity

  11. Frequency of colonization and isolated bacteria from the tip of epidural catheter implanted for postoperative analgesia.

    Science.gov (United States)

    Stabille, Débora Miranda Diogo; Diogo Filho, Augusto; Mandim, Beatriz Lemos da Silva; de Araújo, Lúcio Borges; Mesquita, Priscila Miranda Diogo; Jorge, Miguel Tanús

    2015-01-01

    The increased use of epidural analgesia with catheter leads to the need to demonstrate the safety of this method and know the incidence of catheter colonization, inserted postoperatively for epidural analgesia, and the bacteria responsible for this colonization. From November 2011 to April 2012, patients electively operated and maintained under epidural catheter for postoperative analgesia were evaluated. The catheter tip was collected for semiquantitative and qualitative microbiological analysis. Of 68 cultured catheters, six tips (8.8%) had positive cultures. No patient had superficial or deep infection. The mean duration of catheter use was 43.45 h (18-118) (p=0.0894). The type of surgery (contaminated or uncontaminated), physical status of patients, and surgical time showed no relation with the colonization of catheters. Microorganisms isolated from the catheter tip were Staphylococcus aureus, Pseudomonas aeruginosa and Sphingomonas paucimobilis. Postoperative epidural catheter analgesia, under these study conditions, was found to be low risk for bacterial colonization in patients at surgical wards. Copyright © 2014 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.

  12. Implantation of peritoneal catheters by laparotomy: nephrologists obtained similar results to general surgeons

    Directory of Open Access Journals (Sweden)

    Restrepo CA

    2014-10-01

    Full Text Available Cesar A Restrepo, Carlos Alberto Buitrago, Cielo Holguin Division of Nephrology, Department of Health Sciences, Caldas University, Caldas, ColombiaPurpose: To analyze the complications and costs of minilaparotomies performed by a nephrologist (group A compared with conventional laparotomies performed by a surgeon (group B for peritoneal catheter implantation.Setting: Two university hospitals (Santa Sofia and Caldas in Manizales, Caldas, Colombia.Methods: The study included stage 5 chronic kidney disease patients, with indication of renal replacement therapy, who were candidates for peritoneal dialysis and gave informed consent for a peritoneal catheter implant. Minilaparotomies were performed by a nephrologist in a minor surgery room under local anesthesia. Conventional laparotomies were performed by a surgeon in an operating room under general anesthesia.Results: Two nephrologists inserted 157 peritoneal catheters, and seven general surgeons inserted 185 peritoneal catheters. The groups had similar characteristics: the mean age was 55 years, 49.5% were men, and the primary diagnoses were diabetic nephropathy, hypertensive nephropathy, and unknown etiology. The implant was successful for 98.09% of group A and 99.46% of group B. There was no procedure-related mortality. The most frequent complications in the first 30 days postsurgery in group A versus group B, respectively, were: peritonitis (6.37% versus 3.78%, exit-site infection (3.82% versus 2.16%, tunnel infection (0% versus 0.54%, catheter entrapment by omentum (1.27% versus 3.24%, peritoneal effluent spillover (1.91% versus 2.16%, draining failure (4.46% versus 6.49%, hematoma (0% versus 1.08%, catheter migration with kinking (3.18% versus 2.70%, hemoperitoneum (1.27% versus 0%, and hollow viscera accidental puncture (1.91% versus 0.54%. There were no statistically significant differences in the number of complications between groups. In 2013, the cost of a surgeon-implanted peritoneal

  13. Effect of insulin catheter wear-time on subcutaneous adipose tissue blood flow and insulin absorption in humans

    DEFF Research Database (Denmark)

    Clausen, Trine Schnedler; Kaastrup, Peter; Stallknecht, Bente

    2009-01-01

    blood flow (ATBF) and absorption of the rapid-acting insulin analog insulin aspart over a period of 4 days. METHODS: Teflon insulin catheters (Medtronic, Minneapolis, MN) were inserted into the abdominal SAT of 10 healthy men without diabetes (mean +/- SEM age, 23.0 +/- 1.1 years; body mass index, 22...... +/- 3 min on day 0 to 45 +/- 4 min on day 4 (P = 0.019). Neither peak plasma concentration nor area under the curve of insulin aspart changed significantly. CONCLUSIONS: Insertion of a Teflon insulin catheter into the SAT results in increased ATBF and faster absorption of insulin aspart in a period of 4...

  14. A comparative analysis of radiological and surgical placement of central venous catheters

    International Nuclear Information System (INIS)

    McBride, Kieran D.; Fisher, Ross; Warnock, Neil; Winfield, David A.; Reed, Malcolm W.; Gaines, Peter A.

    1997-01-01

    Purpose. To compare the differences in practice and outcome of all radiologically and surgically placed central venous catheters retrospectively over a 2-year period simultaneously, at a single institution. Methods.A total of 253 Hickman catheters were inserted in 209 patients; 120 were placed radiologically in 102 patients and 133 were placed surgically in 107 patients. The indication was chemotherapy in 76% of radiological and in 47% of surgical cases; the remainder were for total parenteral nutrition and venous access. Results. There were 6 (4.5%) primary surgical failures and a further 17 (13%) surgical cases requiring multiple placement attempts. Pneumothorax occurred once (0.8%) surgically and four times (3.3%) radiologically. There were no radiological primary misplacements but there were five (3.7%) surgical ones. Catheter or central vein thrombosis occurred in four (3.3%) radiological and five (3.7%) surgical cases. The rate of infection per 1000 catheter-days was 1.9 in radiologically placed catheters and 4.0 in surgically placed ones (p<0.001). Average catheter life-span was similar for the two placement methods (100±23 days). Conclusion. Radiological placement is consistently more reliable than surgical placement. There are fewer placement complications and fewer catheter infections overall

  15. Intravesical knotting of feeding tube used as urinary catheter in an infant

    Directory of Open Access Journals (Sweden)

    Mamatha Basavaraju

    2016-09-01

    Full Text Available Infant feeding tube is commonly used to temporarily drain the bladder in pediatric population. A case is described where the tube got knotted inside the bladder probably due to over insertion or bladder spasm caused by irritation of catheter.

  16. Empyema and Effusion: Outcome of Image-Guided Small-Bore Catheter Drainage

    International Nuclear Information System (INIS)

    Keeling, A. N.; Leong, S.; Logan, P. M.; Lee, M. J.

    2008-01-01

    Empyema and complicated pleural effusion represent common medical problems. Current treatment options are multiple. The purpose of this study was to access the outcome of image-guided, small-bore catheter drainage of empyema and effusion. We evaluated 93 small-bore catheters in 82 patients with pleural effusion (n = 30) or empyema (n = 52), over a 2-year period. Image guidance was with ultrasound (US; n = 56) and CT (n = 37). All patients were followed clinically, with catheter dwell times, catheter outcome, pleural fluid outcome, reinsertion rates, and need for urokinase or surgery recorded. Ninety-three small-bore chest drains (mean=10.2 Fr; range, 8.2-12.2 Fr) were inserted, with an average dwell time of 7.81 days for empyemas and 7.14 days for effusions (p > 0.05). Elective removal rates (73% empyema vs 86% effusions) and dislodgement rates (12% empyema vs 13% effusions) were similar for both groups. Eight percent of catheters became blocked and 17% necessitated reinsertion in empyemas, with no catheters blocked or requiring reinsertion in effusions (p < 0.05). Thirty-two patients (51%) required urokinase in the empyema group, versus 2 patients (6%) in the effusion group (p < 0.05). All treatment failures, requiring surgery, occurred in the empyema group (19%; n = 12; p < 0.05). In conclusion, noninfected pleural collections are adequately treated with small-bore catheters, however, empyemas have a failure rate of 19%. The threshold for using urokinase and larger-bore catheters should be low in empyema

  17. Transvaginal closure of urethra and correction of uterovaginal prolapse in neurologically impaired patient with chronic indwelling catheter.

    Science.gov (United States)

    Kubal, U; Arunkalaivanan, A S; Baptiste, M

    2009-08-01

    We report the case of a 38-year-old neurologically impaired woman with continuous urinary incontinence as a result of a chronic indwelling catheter for neurogenic bladder. Long-term catheter resulted in dilatation of urethra and pressure necrosis of urethra, with subsequent incontinence despite the catheter. She also had a stage 3 uterovaginal prolapse. She underwent cystoscopy, closure of urethra and bladder neck by transvaginal route (Feneley procedure), insertion of a suprapubic catheter, sacrospinous fixation and posterior colporrhaphy with prolene mesh (Apogee). Vaginal hysterectomy was declined by the patient and her family. She remained dry at follow-up visit and is happy with the outcome.

  18. Catheter Angiography

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Catheter Angiography Catheter angiography uses a catheter, x-ray ... are the limitations of Catheter Angiography? What is Catheter Angiography? Angiography is a minimally invasive medical test ...

  19. [Frequency of colonization and isolated bacteria from the tip of the epidural catheter implanted for postoperative analgesia].

    Science.gov (United States)

    Stabille, Débora Miranda Diogo; Filho, Augusto Diogo; Mandim, Beatriz Lemos da Silva; Araújo, Lúcio Borges de; Mesquita, Priscila Miranda Diogo; Jorge, Miguel Tanús

    2015-01-01

    The increased use of epidural analgesia with catheter leads to the need to demonstrate the safety of this method and know the incidence of catheter colonization, inserted postoperatively for epidural analgesia, and the bacteria responsible for this colonization. From November 2011 to April 2012, patients electively operated and maintained under epidural catheter for postoperative analgesia were evaluated. The catheter tip was collected for semiquantitative and qualitative microbiological analysis. Of 68 cultured catheters, six tips (8.8%) had positive cultures. No patient had superficial or deep infection. The mean duration of catheter use was 43.45hours (18-118) (p=0.0894). The type of surgery (contaminated or uncontaminated), physical status of patients, and surgical time showed no relation with the colonization of catheters. Microorganisms isolated from the catheter tip were Staphylococcus aureus, Pseudomonas aeruginosa and Sphingomonas paucimobilis. Postoperative epidural catheter analgesia, under this study conditions, was found to be low risk for bacterial colonization in patients at surgical wards. Copyright © 2014 Sociedade Brasileira de Anestesiologia. Publicado por Elsevier Editora Ltda. All rights reserved.

  20. Implementation of the updated 2015 Commission for Hospital Hygiene and Infection Prevention (KRINKO) recommendations "Prevention and control of catheter-associated urinary tract infections" in the hospitals in Frankfurt/Main, Germany.

    Science.gov (United States)

    Heudorf, Ursel; Grünewald, Miriam; Otto, Ulla

    2016-01-01

    The Commission for Hospital Hygiene and Infection Prevention (KRINKO) updated the recommendations for the prevention of catheter-associated urinary tract infections in 2015. This article will describe the implementation of these recommendations in Frankfurt's hospitals in autumn, 2015. In two non-ICU wards of each of Frankfurt's 17 hospitals, inspections were performed using a checklist based on the new KRINKO recommendations. In one large hospital, a total of 5 wards were inspected. The inspections covered the structure and process quality (operating instructions, training, indication, the placement and maintenance of catheters) and the demonstration of the preparation for insertion of a catheter using an empty bed and an imaginary patient, or insertion in a model. Operating instructions were available in all hospital wards; approximately half of the wards regularly performed training sessions. The indications were largely in line with the recommendations of the KRINKO. Alternatives to urinary tract catheters were available and were used more often than the urinary tract catheters themselves (15.9% vs. 13.5%). In accordance with the recommendations, catheters were placed without antibiotic prophylaxis or the instillation of antiseptic or antimicrobial substances or catheter flushing solutions. The demonstration of catheter placement was conscientiously performed. Need for improvement was seen in the daily documentation and the regular verification of continuing indication for a urinary catheter, as well as the omission of regular catheter change. Overall, the recommendations of the KRINKO on the prevention of catheter-associated urinary tract infections were adequately implemented. However, it cannot be ruled out that in situations with time pressure and staff shortage, the handling of urinary tract catheters may be of lower quality than that observed during the inspections, when catheter insertion was done by two nurses. Against this background, a sufficient

  1. Permanent catheters for recurrent ascites-a critical and systematic review of study methodology

    DEFF Research Database (Denmark)

    Christensen, Lars; Wildgaard, Lorna Elizabeth; Wildgaard, Kim

    2016-01-01

    fulfilled the inclusion criteria. Only three studies reported technical success less than 100 %. Data on complications and treatment were not available in all papers; peritonitis (48 %), cellulitis (41 %), prophylactic antibiotics (48 %) and complications to catheter insertion were difficult to distinguish...

  2. Performance evaluation of a robot-assisted catheter operating system with haptic feedback.

    Science.gov (United States)

    Song, Yu; Guo, Shuxiang; Yin, Xuanchun; Zhang, Linshuai; Hirata, Hideyuki; Ishihara, Hidenori; Tamiya, Takashi

    2018-06-20

    In this paper, a novel robot-assisted catheter operating system (RCOS) has been proposed as a method to reduce physical stress and X-ray exposure time to physicians during endovascular procedures. The unique design of this system allows the physician to apply conventional bedside catheterization skills (advance, retreat and rotate) to an input catheter, which is placed at the master side to control another patient catheter placed at the slave side. For this purpose, a magnetorheological (MR) fluids-based master haptic interface has been developed to measure the axial and radial motions of an input catheter, as well as to provide the haptic feedback to the physician during the operation. In order to achieve a quick response of the haptic force in the master haptic interface, a hall sensor-based closed-loop control strategy is employed. In slave side, a catheter manipulator is presented to deliver the patient catheter, according to position commands received from the master haptic interface. The contact forces between the patient catheter and blood vessel system can be measured by designed force sensor unit of catheter manipulator. Four levels of haptic force are provided to make the operator aware of the resistance encountered by the patient catheter during the insertion procedure. The catheter manipulator was evaluated for precision positioning. The time lag from the sensed motion to replicated motion is tested. To verify the efficacy of the proposed haptic feedback method, the evaluation experiments in vitro are carried out. The results demonstrate that the proposed system has the ability to enable decreasing the contact forces between the catheter and vasculature.

  3. Effectiveness of Fluoroscopic and US - Guided Percutaneous Catheter Drainage for Iliopsoas Abscess through the Anterolateral Transabdominal Approach

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Ho Cheol; Shin, Tae Beom; Park, Mee Jung; Kim, Ji Eun; Choi, Hye Young; Bae, Kyung Soo; Choi, Dae Seob; Na, Jae Boem; Jeong, Seong Hoon [Gyeongsang National University Hospital, College of Medicine, Jinju (Korea, Republic of)

    2011-02-15

    We evaluated the effectiveness of performing fluoroscopic and ultrasonography guided percutaneous catheter drainage (PCD) through the anterolateral transabdominal approach for treating iliopsoas abscess. From January 2008 to December 2009, fluoroscopic and US-guided PCD through the anterolateral transabdominal approach was performed on sixteen iliopsoas abscesses of fourteen patients (7 males and 7 females; mean age: 63 years; age range: 30-87 years). Six abscesses were on the right side and ten abscesses were on the left side. The location of the abscesses were the psoas muscle (n=7), the iliacus muscle (n=7) and the iliopsoas muscle (n=2). All the procedures were performed under fluoroscopy and US guidance in the angiography room. The clinical findings before and after the procedure, the duration of catheter insertion and the procedure-related complications were evaluated. 15 out of the 16 iliopsoas abscesses were effectively treated. The duration of catheter insertion was 5- 27 days (mean: 14.6) days. No patient had significant complications during or after drainage. One patient died of uncontrolled diabetes complications and shock on the 9th day after percutaneous catheter drainage. One recurrence was noted 5 months after removal of the catheter. This patient underwent aspiration and antibiotic treatment for this lesion and the patient improved. Fluoroscopic and US-guided PCD for iliopsoas abscess through the anterolateral transabdominal approach is an effective and safe procedure

  4. Urinary catheters

    Science.gov (United States)

    Catheter - urine; Foley catheter; Indwelling catheter; Suprapubic catheters ... stones Blood infections ( septicemia ) Blood in the urine (hematuria) Kidney damage (usually only with long-term, indwelling ...

  5. Implementation of the updated 2015 Commission for Hospital Hygiene and Infection Prevention (KRINKO recommendations “Prevention and control of catheter-associated urinary tract infections” in the hospitals in Frankfurt/Main, Germany

    Directory of Open Access Journals (Sweden)

    Heudorf, Ursel

    2016-06-01

    Full Text Available Aim: The Commission for Hospital Hygiene and Infection Prevention (KRINKO updated the recommendations for the prevention of catheter-associated urinary tract infections in 2015. This article will describe the implementation of these recommendations in Frankfurt’s hospitals in autumn, 2015.Material and methods: In two non-ICU wards of each of Frankfurt’s , inspections were performed using a checklist based on the new KRINKO recommendations. In one large hospital, a total of were inspected. The inspections covered the structure and process quality (operating instructions, training, indication, the placement and maintenance of catheters and the demonstration of the preparation for insertion of a catheter using an empty bed and an imaginary patient, or insertion in a model.Results: Operating instructions were available in all hospital wards; approximately half of the wards regularly performed training sessions. The indications were largely in line with the recommendations of the KRINKO. Alternatives to urinary tract catheters were available and were used more often than the urinary tract catheters themselves (15.9% vs. 13.5%. In accordance with the recommendations, catheters were placed without antibiotic prophylaxis or the instillation of antiseptic or antimicrobial substances or catheter flushing solutions. The demonstration of catheter placement was conscientiously performed. Need for improvement was seen in the daily documentation and the regular verification of continuing indication for a urinary catheter, as well as the omission of regular catheter change.Conclusion: Overall, the recommendations of the KRINKO on the prevention of catheter-associated urinary tract infections were adequately implemented. However, it cannot be ruled out that in situations with time pressure and staff shortage, the handling of urinary tract catheters may be of lower quality than that observed during the inspections, when catheter insertion was done by two

  6. Prospective study of catheter-related central vein thrombosis in home parenteral nutrition patients with benign disease using serial venous Doppler ultrasound.

    Science.gov (United States)

    Cuerda, Cristina; Joly, Francisca; Corcos, Olivier; Concejo, Javier; Puiggrós, Carolina; Gil, Carmen; Pironi, Loris

    2016-02-01

    Catheter-related central vein thrombosis (CRVT) is a severe complication of home parenteral nutrition (HPN) that may be clinically manifest or subclinical. The aims of the study were to prospectively investigate the incidence of CRVT in patients on HPN with benign disease and determine the influence of different variables on this complication. A prospective, multicentre, observational study in the Home Artificial Nutrition-Chronic Intestinal Failure ESPEN group was performed. Patients with benign disease starting HPN or already on HPN after the insertion of a new catheter, were recruited and followed up with Color Doppler Duplex Sonography (CDDS) evaluations at baseline, 1 week, 3, 6 and 12 months after catheter insertion. Fisher's exact test was used to calculate the association of different variables (related to the patient, type of catheter, vascular access, insertion method, catheter care and anticoagulant treatment) with CRVT events. Sixty-two patients (31 males, 31 females) aged 50 ± 19 (19-83) years were included and followed for a median 363 days, with an Inter Quartile Range of 180-365 days, and a total of 16,186 catheter-days. Six patients had previous CRVT and 16 had history of thromboembolic disease (pulmonary and mesenteric). Forty one patients were receiving anticoagulant treatment. Fifty two patients had tunneled catheters and 10 implanted ports. Two patients had symptomatic thrombosis at 3 and 12 months of follow-up (2 and 3 weeks after normal routine CDDS evaluation). The incidence of CRVT was 0.045/catheter/year. CRVT was not significantly associated with any of the variables analyzed. The incidence of CRVT in patients on HPN for benign disease followed by CDDS is low in the first year of catheterization. We did not observe any case of asymptomatic CRVT. Based on our data, CDDS seems to have low effectiveness as a screening tool for CRVT in asymptomatic patients on HPN with benign disease. Copyright © 2015 Elsevier Ltd and European Society for

  7. Short daily hemodialysis is associated with lower plasma FGF23 levels when compared with conventional hemodialysis.

    Science.gov (United States)

    Zaritsky, Joshua; Rastogi, Anjay; Fischmann, George; Yan, Jieshi; Kleinman, Kenneth; Chow, Georgina; Gales, Barbara; Salusky, Isidro B; Wesseling-Perry, Katherine

    2014-02-01

    The utilization of short-term daily hemodialysis has increased over the last few years, but little is known on its effects on the control of serum phosphate and fibroblast growth factor 23 (FGF23) levels. We therefore performed a cross-sectional study to compare FGF23 levels as well as other biochemical variables between 24 patients undergoing short daily hemodialysis using the NxStage System® and 54 patients treated with conventional in-center hemodialysis. FGF23 levels were measured using the second-generation Immutopics® C-terminal assay. Short daily hemodialysis patients were younger than patients on conventional hemodialysis but there were no differences between groups in the duration of end-stage renal disease nor in the number of patients with residual renal function. A greater number of short daily hemodialysis patients received vitamin D sterol therapy than did conventional in-center hemodialysis patients while there were no differences in the use of different phosphate binders and calcimimetic therapy between groups. Overall serum calcium, phosphorus and intact parathyroid hormone levels were similar between groups. While serum phosphorus levels correlated with FGF23 concentrations in each group separately [r=0.522 (P<0.01) and r=0.42 (P<0.01) in short daily and conventional in-center hemodialysis, respectively], FGF23 levels were lower [823 RU/mL (263, 2169)] in the patients receiving short daily hemodialysis than in patients treated with conventional hemodialysis [2521 RU/mL (909, 5556)] (P<0.01 between groups). These findings demonstrate that FGF23 levels are significantly lower in short daily hemodialysis patients and suggest that FGF23 levels may be a more sensitive biomarker of cumulative phosphate burden than single or multiple serum phosphorus determinations in patients treated with hemodialysis.

  8. Value of local electrogram characteristics predicting successful catheter ablation of left-versus right-sided accessory atrioventricular pathways by radiofrequency current.

    Science.gov (United States)

    Lin, J L; Schie, J T; Tseng, C D; Chen, W J; Cheng, T F; Tsou, S S; Chen, J J; Tseng, Y Z; Lien, W P

    1995-01-01

    Despite similar guidance by local electrogram criteria, catheter ablation of right-sided accessory atrioventricular (AV) pathways by radiofrequency current has been less effective than that of left-sided ones. In order to elucidate the possible diversities in local electrosignal criteria, we systematically analyzed the morphological and timing characteristics of 215 bipolar local electrograms from catheter ablation sites of 65 left-sided accessory AV pathways and of 356 from those of 37 right-sided ones in 92 consecutive patients with Wolff-Parkinson-White syndrome or AV reentrant tachycardia incorporating concealed accessory AV pathways. After stepwise multivariate analysis, we selected the presence of a possible accessory pathway potential, local ventricular activation preceding QRS complex for 20 ms or more during ventricular insertion mapping, and the local retrograde ventriculoatrial (VA) continuity, local retrograde VA interval right-sided targets only) during atrial insertion mapping, as independent local electrogram predictors for successful ablation of left- and right-sided accessory AV pathways. Combination of all local electrogram predictors could have moderate chance of success (80 and 51%) for the ventricular and atrial insertion ablation of left-sided accessory AV pathways, but only low probability of success (40% in ventricular insertion ablation) or very low sensitivity (12.5% in atrial insertion ablation) for right-sided ones. In conclusion, with the present approach, successful catheter ablation of right-sided accessory AV pathways, compared to left-sided ones, still necessitate a breakthrough in the precision mapping and the efficiency of energy delivery.

  9. Catheter-related Mycobacterium abscessus bacteremia manifested with skin nodules, pneumonia, and mediastinal lymphadenopathy

    Directory of Open Access Journals (Sweden)

    Shou-Hsin Su

    2013-01-01

    Full Text Available Although previously rare, catheter-related bloodstream infection caused by rapidly growing mycobacteria is now increasingly encountered, especially among cancer patients who have catheters implanted for chemotherapy treatments. A 73-year-old female patient with acute myeloid leukemia (AML had Mycobacterium abscessus bacteremia with manifestations of multiple skin nodules, pneumonia, and mediastinal lymphadenopathy 4 months after the implantation of a peripherally inserted central catheter (PICC for the delivery of chemotherapy. The catheter-related M. abscessus bacteremia was confirmed by positive blood cultures of specimens drawn from a PICC line and a peripheral vein. She defervesced with the administration of meropenem, amikacin, levofloxacin, clarithromycin, and by the removal of PICC. Her fever subsided for 3 months with the disappearance of skin and lung lesions; however, she died of AML relapse. Bacteremia and skin infection caused by M. abscessus can be detected by culture and pathological examinations and should be considered in leukemia patients with a PICC. With appropriate laboratory diagnosis, M. abscessus bacteremia with disseminated infections can improve with catheter removal and combination antimicrobial therapy.

  10. Effects of starting hemodialysis with an arteriovenous fistula or central venous catheter compared with peritoneal dialysis: a retrospective cohort study

    Directory of Open Access Journals (Sweden)

    Coentrão Luis

    2012-08-01

    Full Text Available Abstract Background Although several studies have demonstrated early survival advantages with peritoneal dialysis (PD over hemodialysis (HD, the reason for the excess mortality observed among incident HD patients remains to be established, to our knowledge. This study explores the relationship between mortality and dialysis modality, focusing on the role of HD vascular access type at the time of dialysis initiation. Methods A retrospective cohort study was performed among local adult chronic kidney disease patients who consecutively initiated PD and HD with a tunneled cuffed venous catheter (HD-TCC or a functional arteriovenous fistula (HD-AVF in our institution in the year 2008. A total of 152 patients were included in the final analysis (HD-AVF, n = 59; HD-TCC, n = 51; PD, n = 42. All cause and dialysis access-related morbidity/mortality were evaluated at one year. Univariate and multivariate analysis were used to compare the survival of PD patients with those who initiated HD with an AVF or with a TCC. Results Compared with PD patients, both HD-AVF and HD-TCC patients were more likely to be older (pp = 0.017 and cardiovascular disease (p = 0.020. Overall, HD-TCC patients were more likely to have clinical visits (p = 0.069, emergency room visits (ppvs. 0.93 vs. 0.64, per patient-year; pvs. 0.07 vs. 0.14, per patient-year; p = 0.034 than HD-AVF and PD patients, respectively. The survival rates at one year were 96.6%, 74.5% and 97.6% for HD-AVF, HD-TCC and PD groups, respectively (pp = 0.024. Conclusion Our results suggest that HD vascular access type at the time of renal replacement therapy initiation is an important modifier of the relationship between dialysis modality and survival among incident dialysis patients.

  11. Efficacy of Minocycline and EDTA Lock Solution in Preventing Catheter-Related Bacteremia, Septic Phlebitis, and Endocarditis in Rabbits

    Science.gov (United States)

    Raad, Issam; Hachem, Ray; Tcholakian, Robert K.; Sherertz, Robert

    2002-01-01

    To determine the efficacy of antibiotic catheter lock solution in preventing catheter-related infections, silicone catheters were tunneled and inserted into the jugular veins of 18 rabbits. The catheters were challenged with an intraluminal injection of 105 CFU of slime-producing Staphylococcus epidermidis in 0.1 ml of water. The catheters were maintained on heparin (100 IU/ml) flush for the first 3 days. On day 3, quantitative blood samples for culture were obtained from the catheters and ear veins, which documented catheter-related bacteremia, and the rabbits were randomized to have their catheters flushed as follows: five animals were continued on heparin (100 IU/ml), five animals received vancomycin (3 mg/ml) with heparin (100 IU/ml), and eight animals received 3 mg of minocycline per ml with 30 mg of EDTA per ml (M-EDTA). All animals were killed at day 7. Blood, catheters, jugular veins, and heart valves were cultured quantitatively. Animals maintained on heparin developed catheter-related colonization, bacteremia, septic phlebitis, and endocarditis. Vancomycin-heparin partially prevented catheter colonization, bacteremia, and phlebitis (P = 0.2). M-EDTA completely prevented catheter colonization, catheter-related bacteremia, and phlebitis in all of the animals (P phlebitis, and endocarditis in rabbits. PMID:11796338

  12. Using central venous catheter for suprapubic catheterization in cardiac surgery

    Directory of Open Access Journals (Sweden)

    Bilehjani E

    2017-01-01

    Full Text Available Eissa Bilehjani,1 Solmaz Fakhari2 1Department of Cardiovascular Anesthesia, Tabriz University of Medical Sciences, Madani Heart Hospital, 2Department of Anesthesiology, Tabriz University of Medical Sciences, Madani Heart Hospital, Tabriz, Iran Abstract: Suprapubic catheterization is an alternative method for urinary drainage that is used when transurethral catheterization fails. Traditionally, inserted large-bore suprapubic catheters may cause fatal complications. During the past decade, we used a small central venous catheter (CVC suprapubicly in 16 male patients for the purpose of urinary drainage, when transurethral catheterization failed. The procedure is performed in no more than 10 minutes. Success rate was 100% and this approach did not lead to any complications. In conclusion, placing a CVC for suprapubic drainage is a safe method with a high success rate and we recommend it in patients with failed transurethral catheterization after a few attempts (2–3 attempts. Keywords: suprapubic catheterization complication, urethral catheterization, central venous catheter, Seldinger’s technique, cardiac surgery

  13. Comparison of three types of central venous catheters in patients with malignant tumor receiving chemotherapy

    Directory of Open Access Journals (Sweden)

    Fang S

    2017-07-01

    Full Text Available Shirong Fang,1 Jinhong Yang,2 Lei Song,3 Yan Jiang,1 Yuxiu Liu4 1Department of Anesthesiology, 2Department of Oncology, Weifang People’s Hospital, Weifang, 3Intensive Care Unit, The Affiliated Hospital of Qingdao University, Qingdao, 4Nursing College, Weifang Medical University, Weifang, People’s Republic of China Background: Central venous catheters (CVCs have been an effective access for chemotherapy instead of peripherally intravenous catheters. There were limited studies on the choices and effects of different types of CVCs for chemotherapy. The aim of this study was to compare the complications, cost, and patients’ quality of life and satisfaction of three commonly used CVCs for chemotherapy, such as implanted venous port, peripherally inserted central catheters (PICCs, and external non-tunneled central venous catheters (NTCs.Methods: A double-center prospective cohort study was carried out from March 2014 to December 2016. Catheterization situation, complications, catheter maintenance, cost, and patients’ quality of life and satisfaction were recorded, investigated, and analyzed. Forty-five ports, 60 PICCs and 40 NTCs were included. All the CVCs were followed up to catheter removal.Results: There was no statistical difference in catheterization success rates between port and PICC. NTC had less success rate by one puncture compared with port. Ports had fewer complications compared with PICCs and NTCs. The complication rates of ports, PICCs and NTCs were 2.2%, 40%, and 27.5%, respectively. If the chemotherapy process was <12 months, NTCs cost least, and the cost of port was much higher than PICC and NTC. When the duration time was longer than 12 months, the cost of port had no difference with the cost of PICC. Quality of life and patients’ satisfaction of port group were significantly higher than the other two groups. Conclusion: Although port catheterization costs more and needs professional medical staff and strict operational

  14. Central venous catheters: detection of catheter complications and therapeutical options

    International Nuclear Information System (INIS)

    Gebauer, B.; Beck, A.; Wagner, H.J.; Vivantes-Kliniken, Hellersdorf und Prenzlauer Berg

    2008-01-01

    For modern medicine central venous catheters play an important role for diagnostic and therapeutic options. Catheter implantation, complication detection and therapy of catheter complications are an increasing demand for the radiologist. The review article provides an overview of different catheter types, their indications, advantages and disadvantages. Catheter malpositions are usually detectable in conventional X-ray. Most malpositions are correctable using interventional-radiological techniques. In addition therapeutical options for thrombotic complications (venous thrombosis, catheter occlusion, fibrin sheath) are discussed. In case of an infectious catheter complication, usually a catheter extraction and re-implantation is necessary

  15. Variable pulmonary manifestations in hemodialysis patients

    International Nuclear Information System (INIS)

    Kim, Yoo Kyung; Shim, Sung Shine; Shin, Jung Hee; Choi, Gyu Bock; Lee, Kyung Soo; Yi, Chin A; Oh, Yu Whan

    2003-01-01

    A wide variety of pulmonary disorders related to hemodialysis or pre-existing renal disease occurs in hemodialysis patients. The disorders may be classified as 1) pulmonary abnormalities associated with chronic renal failures; 2) pulmonary complications arising during hemodialysis; 3) pulmonary infection; or 4) pulmonary-renal syndrome. An awareness of the various possible pulmonary disorders arising in hemodialysis patients may be helpful for the proper and timely management of such patients. We describe and illustrate various radiographic and CT findings of variable pulmonary disorders in hemodialysis patients

  16. Catheter Angiography

    Medline Plus

    Full Text Available ... Z Catheter Angiography Catheter angiography uses a catheter, x-ray imaging guidance and an injection of contrast material ... vessels in the body. Angiography is performed using: x-rays with catheters computed tomography (CT) magnetic resonance imaging ( ...

  17. WE-G-17A-05: Real-Time Catheter Localization Using An Active MR Tracker for Interstitial Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Wang, W; Damato, A; Viswanathan, A; Cormack, R [Dana Farber Cancer Institute / Brigham and Women' s Hospital, Boston, MA (United States); Harvard Medical School, Boston, MA (United States); Penzkofer, T; Schmidt, E [Brigham and Women' s Hospital, Boston, MA (United States); Pan, L; Gilson, W [Siemens Corporation, Corporate Technology, Baltimore, MD (United States); Seethamraju, R [Siemens Healthcare, Boston, MA (United States)

    2014-06-15

    Purpose: To develop a novel active MR-tracking system which can provide accurate and rapid localization of brachytherapy catheters, and assess its reliability and spatial accuracy in comparison to standard catheter digitization using MR images. Methods: An active MR tracker for brachytherapy was constructed by adding three printed-circuit micro-coils to the shaft of a commercial metallic stylet. A gel phantom with an embedded framework was built, into which fifteen 14-Gauge catheters were placed, following either with parallel or crossed paths. The tracker was inserted sequentially into each catheter, with MR-tracking running continuously. Tracking was also performed during the tracker's removal from each catheter. Catheter trajectories measured from the insertion and the removal procedures using the same micro-coil were compared, as well as trajectories obtained using different micro-coils. A 3D high-resolution MR image dataset of the phantom was acquired and imported into a treatment planning system (TPS) for catheter digitization. A comparison between MR-tracked positions and positions digitized from MR images by TPS was performed. Results: The MR tracking shows good consistency for varying catheter paths and for all micro-coils (mean difference ∼1.1 mm). The average distance between the MR-tracking trajectory and catheter digitization from the MR images was 1.1 mm. Ambiguity in catheter assignment from images due to crossed paths was resolved by active tracking. When tracking was interleaved with imaging, real-time images were continuously acquired at the instantaneous tip positions and displayed on an external workstation. Conclusion: The active MR tracker may be used to provide an independent measurement of catheter location in the MR environment, potentially eliminating the need for subsequent CT. It may also be used to control realtime imaging of catheter placement. This will enable MR-based brachytherapy planning of interstitial implants without

  18. WE-G-17A-05: Real-Time Catheter Localization Using An Active MR Tracker for Interstitial Brachytherapy

    International Nuclear Information System (INIS)

    Wang, W; Damato, A; Viswanathan, A; Cormack, R; Penzkofer, T; Schmidt, E; Pan, L; Gilson, W; Seethamraju, R

    2014-01-01

    Purpose: To develop a novel active MR-tracking system which can provide accurate and rapid localization of brachytherapy catheters, and assess its reliability and spatial accuracy in comparison to standard catheter digitization using MR images. Methods: An active MR tracker for brachytherapy was constructed by adding three printed-circuit micro-coils to the shaft of a commercial metallic stylet. A gel phantom with an embedded framework was built, into which fifteen 14-Gauge catheters were placed, following either with parallel or crossed paths. The tracker was inserted sequentially into each catheter, with MR-tracking running continuously. Tracking was also performed during the tracker's removal from each catheter. Catheter trajectories measured from the insertion and the removal procedures using the same micro-coil were compared, as well as trajectories obtained using different micro-coils. A 3D high-resolution MR image dataset of the phantom was acquired and imported into a treatment planning system (TPS) for catheter digitization. A comparison between MR-tracked positions and positions digitized from MR images by TPS was performed. Results: The MR tracking shows good consistency for varying catheter paths and for all micro-coils (mean difference ∼1.1 mm). The average distance between the MR-tracking trajectory and catheter digitization from the MR images was 1.1 mm. Ambiguity in catheter assignment from images due to crossed paths was resolved by active tracking. When tracking was interleaved with imaging, real-time images were continuously acquired at the instantaneous tip positions and displayed on an external workstation. Conclusion: The active MR tracker may be used to provide an independent measurement of catheter location in the MR environment, potentially eliminating the need for subsequent CT. It may also be used to control realtime imaging of catheter placement. This will enable MR-based brachytherapy planning of interstitial implants without

  19. Challenges for Nurses Caring for Individuals with Peripherally Inserted Central Catheters in Skilled Nursing Facilities.

    Science.gov (United States)

    Harrod, Molly; Montoya, Ana; Mody, Lona; McGuirk, Helen; Winter, Suzanne; Chopra, Vineet

    2016-10-01

    To understand the perceived preparedness of frontline nurses (registered nurses (RNs), licensed practical nurses (LPNs)), unit nurse managers, and skilled nursing facility (SNF) administrators in providing care for residents with peripherally inserted central catheters (PICCs) in SNFs. Exploratory, qualitative pilot study. Two community based SNFs. Residents with PICCs, frontline nurses (RNs, LPNs), unit nurse managers, and SNF administrators. Over 36 weeks, 56 residents with PICCs and their nurses were observed and informally interviewed, focusing on PICC care practices and documentation. In addition, baseline PICC data were collected on placement indication (e.g., antimicrobial administration), placement setting (hospital vs SNF), and dwell time. Focus groups were then conducted with frontline nurses and unit nurse managers, and semistructured interviews were conducted with SNF administrators to evaluate perceived preparedness for PICC care. Data were analyzed using a descriptive analysis approach. Variations in documentation were observed during weekly informal interviews and observations. Differences were noted between resident self-reported PICC concerns (quality of life) and those described by frontline nurses. Deficiencies in communication between hospitals and SNFs with respect to device care, date of last dressing change, and PICC removal time were also noted. During focus group sessions, perceived inadequacy of information at the time of care transitions, limited availability of resources to care for PICCs, and gaps in training and education were highlighted as barriers to improving practice and safety. Practices for PICC care in SNFs can be improved. Multimodal strategies that enhance staff education, improve information exchange during care transitions, and increase resource availability in SNFs appear necessary to enhance PICC care and safety. © 2016, Copyright the Authors Journal compilation © 2016, The American Geriatrics Society.

  20. Convective Leakage Makes Heparin Locking of Central Venous Catheters Ineffective Within Seconds: Experimental Measurements in a Model Superior Vena Cava.

    Science.gov (United States)

    Barbour, Michael C; McGah, Patrick M; Ng, Chin H; Clark, Alicia M; Gow, Kenneth W; Aliseda, Alberto

    2015-01-01

    Central venous catheters (CVCs), placed in the superior vena cava (SVC) for hemodialysis or chemotherapy, are routinely filled while not in use with heparin, an anticoagulant, to maintain patency and prevent thrombus formation at the catheter tip. The heparin-locking procedure, however, places the patient at risk for systemic bleeding, as heparin is known to leak from the catheter into the blood stream. We provide evidence from detailed in vitro experiments that shows the driving mechanism behind heparin leakage to be convective-diffusive transport due to the pulsatile flow surrounding the catheter. This novel mechanism is supported by experimental planar laser-induced fluorescence (PLIF) and particle image velocimetry (PIV) measurements of flow velocity and heparin transport from a CVC placed inside a model SVC inside a pulsatile flow loop. The results predict an initial, fast (<10 s), convection-dominated phase that rapidly depletes the concentration of heparin in the near-tip region, the region of the catheter with side holes. This is followed by a slow, diffusion-limited phase inside the catheter lumen, where the concentration is still high, that is insufficient at replenishing the lost heparin concentration in the near-tip region. The results presented here, which are consistent with previous in vivo estimates of 24 hour leakage rates, predict that the concentration of heparin in the near-tip region is essentially zero for the majority of the interdialytic phase, rendering the heparin locking procedure ineffective.

  1. Safety of a New Compact Male Intermittent Catheter: Randomized, Cross-Over, Single-Blind Study in Healthy Male Volunteers

    DEFF Research Database (Denmark)

    Bagi, Per; Hannibalsen, Jane; Permild, Rikke

    2011-01-01

    in hematuria (p = 0.54) or discomfort/stinging/pain at first micturition (p = 0.56). During insertion, handling was easier (p = 0.0001) and touching the coating was necessary less often (2.2 vs. 81.3% of catheterizations; p catheter; it was preferred by nurses for 20 of 23......Introduction: A new compact male intermittent catheter was compared with a regular intermittent male catheter in terms of safety and acceptability. Methods: In this randomized, single-blind, cross-over study, healthy male volunteers were catheterized twice with a compact catheter and twice...... with a regular catheter. Results: 28 participants were enrolled. Mean ± SD discomfort (visual analogue scale; primary objective) was 2.25 ± 1.5 and 2.52 ± 1.8 for the compact and regular catheters, respectively (difference -0.27; 95% confidence interval -0.73 to 0.19); there was no significant difference...

  2. Role of ultrasound for central catheter tip localization in neonates: a review of the current evidence.

    Science.gov (United States)

    Sharma, Deepak; Farahbakhsh, Nazanin; Tabatabaii, Seyyed Ahmad

    2018-02-15

    Central catheters are known as "life lines" in intensive care units and are used frequently in neonatal intensive care unit (NICU) for multiple indications. The central catheters used in NICU includes umbilical venous catheter (UVC), umbilical arterial catheter (UAC) and peripherally inserted central catheter (PICC) lines. The tip of these central lines needs to be in a correct position as malpositioned central line tips lead to many neonatal complications. Radiograph either abdomen or chest is the most widely used modality for locating the tip of the central catheter. There are many disadvantages of radiographic confirmation of tip position and recently ultrasound (USG)/echocardiography has been used for localization of catheter tip. USG provides real-time assessment of the tip position with other added advantages like no radiation exposure, need for minimal training for performing USG, minimal handling of the neonate, identification of migration of central lines and making repositioning of central lines under USG guidance. The present evidence supports the use of USG/Echo for localization of central catheter tip and USG has shown to have good sensitivity, specificity, positive predictive value and negative predictive value when compared with a radiograph. In this review, we discuss about the role of USG/Echo in the identification of tip of central catheters in neonatal care.

  3. Infection and natural history of emergency department-placed central venous catheters.

    Science.gov (United States)

    LeMaster, Christopher H; Schuur, Jeremiah D; Pandya, Darshan; Pallin, Daniel J; Silvia, Jennifer; Yokoe, Deborah; Agrawal, Ashish; Hou, Peter C

    2010-11-01

    Central line-associated bloodstream infection (CLABSI, hereafter referred to in this paper as "bloodstream infection") is a leading cause of hospital-acquired infection. To our knowledge, there are no previously published studies designed to determine the rate of bloodstream infection among central venous catheters placed in the emergency department (ED). We design a retrospective chart review methodology to determine bloodstream infection and duration of catheterization for central venous catheters placed in the ED. Using hospital infection control, administrative, and ED billing databases, we identified patients with central venous catheters placed in the ED between January 1, 2007, and December 31, 2008, at one academic, urban ED with an annual census of 57,000. We performed a structured, explicit chart review to determine duration of catheterization and confirm bloodstream infection. We screened 4,251 charts and identified 656 patients with central venous catheters inserted in the ED, 3,622 catheter-days, and 7 bloodstream infections. The rate of bloodstream infection associated with central venous catheters placed in the ED was 1.93 per 1,000 catheter-days (95% confidence interval 0.50 to 3.36). The mean duration of catheterization was 5.5 days (median 4; range 1 to 29 days). Among infected central venous catheters, the mean duration of catheterization was 8.6 days (median 7; range 2 to 19 days). A total of 667 central venous catheters were placed in the internal jugular (392; 59%), subclavian (145; 22%), and femoral (130; 19%) veins. The sensitivity of using ED procedural billing code for identifying ED-placed central venous catheters among patients subsequently admitted to any ICU was 74.9% (95% confidence interval 71.4% to 78.3%). The rate of ED bloodstream infection at our institution is similar to current rates in ICUs. Central venous catheters placed in the ED remain in admitted patients for a substantial period. Copyright © 2010 American College of

  4. Relative incidence of phlebitis associated with peripheral intravenous catheters in the lower versus upper extremities.

    Science.gov (United States)

    Benaya, A; Schwartz, Y; Kory, R; Yinnon, A M; Ben-Chetrit, E

    2015-05-01

    Peripheral venous access in elderly, hospitalized patients is often challenging. The usual alternative is insertion of a central venous catheter, with associated risk for complications. The purpose of this investigation was to determine the relative incidence of phlebitis secondary to lower as compared to upper extremity intravenous catheters (IVCs) and associated risk factors. A non-randomized, observational, cohort-controlled study was carried out. Consecutive patients receiving a lower extremity IVC were enrolled and compared with patients receiving an upper extremity IVC. Patients were followed from insertion until removal of the IVC. The major endpoint was phlebitis. The incidence of phlebitis secondary to upper extremity IVCs was 3/50 (6 %) compared to 5/53 (9.4 %) in lower extremity IVCs (χ(2) Yates = 0.08, p = 0.776). Age, gender, obesity, diabetes mellitus, site (arm versus leg, left versus right), and size of needle were not found to be risk factors for phlebitis according to univariate analysis. None of the patients developed bloodstream infection. In elderly patients with poor venous access, lower extremity IVCs are a reasonable and low-risk alternative to central venous catheters.

  5. The effect of acupuncture treatment for insomnia in chronic hemodialysis patients

    Science.gov (United States)

    Widjaja, J. A.; Simadibrata, C.; Srilestari, A.; Marbun, M. B. H.

    2017-08-01

    Insomnia is a problem often experienced by patients on chronic dialysiswhich reduces their quality of life. Current management of insomnia with this specific group of patients has yet to produce optimum results. In this study, we explored the roleof acupuncture as a treatment for symptoms of insomnia in patients on chronic dialysis. Twenty-eight hemodialysis patients suffering from insomnia were divided randomly into two groups, an acupuncture group (n = 15) who received acupuncture treatment at the points HT7 Shenmen, PC6 Neiguan, GV20 Baihui, and EX-HN1 Sishenchong, anda control group (n = 13) who underwenta sham procedure in which a needle was inserted into an elastic bandage at the same points. The acupuncture treatment was done during hemodialysis twice a week for five weeks. PSQI scores and the WHOQOL-BREF were assessed before treatment, after the fifth treatment, and at the end of the treatment. Significant differences were found in the PSQI score ((4.20±2.27 vs. 11.23±3.37) p = 0.000) and in the WHOQOL-BREF ((94.53±10.08 vs. 82.69±11.90) p = 0.008) between the acupuncture group and the control group by the end of the period of treatment. Acupuncture treatment effectively improved the quality of sleep and the quality of life for these chronic hemodialysis patients.

  6. Urinary catheter - infants

    Science.gov (United States)

    Bladder catheter - infants; Foley catheter - infants; Urinary catheter - neonatal ... A urinary catheter is a small, soft tube placed in the bladder. This article addresses urinary catheters in babies. WHY IS ...

  7. Inadvertent positioning of suprapubic catheter in urethra: a serious complication during change of suprapubic cystostomy in a spina bifida patient - a case report.

    Science.gov (United States)

    Vaidyanathan, Subramanian; Hughes, Peter L; Soni, Bakul M; Oo, Tun; Singh, Gurpreet

    2009-12-22

    Spinal cord injury patients are at risk for developing unusual complications such as autonomic dysreflexia while changing suprapubic cystostomy. We report a male patient with spina bifida in whom the Foley catheter was placed in the urethra during change of suprapubic cystostomy with serious consequences. A male patient, born in 1972 with spina bifida and paraplaegia, underwent suprapubic cystostomy in 2003 because of increasing problems with urethral catheter. The patient would come to spinal unit for change of suprapubic catheter every four to six weeks. Two days after a routine catheter change in November 2009, this patient woke up in the morning and noticed that the suprapubic catheter had come out. He went straight to Accident and Emergency. The suprapubic catheter was changed by a health professional and this patient was sent home. But the suprapubic catheter did not drain urine. This patient developed increasing degree of pain and swelling in suprapubic region. He did not pass any urine per urethra. He felt sick and came to spinal unit five hours later. About twenty ml of contrast was injected through suprapubic catheter and X-rays were taken. The suprapubic catheter was patent; the catheter was not blocked. The Foley catheter could be seen going around in a circular manner through the urinary bladder into the urethra. The contrast did not opacify urinary bladder; but proximal urethra was seen. The tip of Foley catheter was lying in proximal urethra. The balloon of Foley catheter had been inflated in urethra. When the balloon of Foley catheter was deflated, this patient developed massive bleeding per urethra. A sterile 22 French Foley catheter was inserted through suprapubic track. The catheter drained bloody urine. He was admitted to spinal unit and received intravenous fluids and meropenem. Haematuria subsided after 48 hours. The patient was discharged home a week later in a stable condition. This case shows that serious complications can occur during

  8. Stent tunnel technique to save thrombosed native hemodialysis fistula with extensive venous aneurysm

    Directory of Open Access Journals (Sweden)

    Rabellino M

    2017-07-01

    Full Text Available Martin Rabellino,1 Guillermo J Rosa-Diez,2 Sergio A Shinzato,1 Pablo Rodriguez,1 Oscar A Peralta,1 Maria S Crucelegui,2 Rosario Luxardo,2 Agustina Heredia-Martinez,2 Mariela I Bedini-Rocca,2 Ricardo D García-Mónaco1 1Department of Angiography and Endovascular Therapy, 2Department of Nephrology, Hospital Italiano de Buenos Aires, Buenos Aires, Argentina Introduction and purpose: The increasing number of patients undergoing hemodialysis and the limited number of access sites have resulted in an increasing number of techniques to maintain vascular access for hemodialysis. Thrombosed arteriovenous (AV fistulas with large venous aneurysms have poor treatment results, with both endovascular and surgical techniques, leading to a high rate of definitive AV access loss. The purpose of this study was to review the feasibility and initial results of this novel endovascular treatment of thrombosed AV fistulas with large venous aneurysms.Materials and methods: A novel endovascular treatment technique of inserting nitinol auto-expandable uncovered stents stretching through the whole puncture site area, thus creating a tunnel inside the thrombus, was retrospectively analyzed and described.Results: A total of 17 stents were placed in 10 hemodialysis fistulas, with a mean venous coverage length of 17.8 cm. In all the cases, 100% technical success was achieved, with complete restoration of blood flow in all patients. There were no procedure-related complications. The mean follow-up was 167 days (range 60–420 days, with a primary and assisted patency of 80% and 100%, respectively. No multiple trans-stent struts-related complications were observed. Three stent fractures were diagnosed with plain films at the site of puncture without consequence in the venous access permeability.Conclusion: The “stent tunnel technique” is a feasible, safe and effective alternative to salvage native hemodialysis access, thus extending the function of the venous access with

  9. Reducing catheter-associated urinary tract infections: a quality-improvement initiative.

    Science.gov (United States)

    Davis, Katherine Finn; Colebaugh, Ann M; Eithun, Benjamin L; Klieger, Sarah B; Meredith, Dennis J; Plachter, Natalie; Sammons, Julia Shaklee; Thompson, Allison; Coffin, Susan E

    2014-09-01

    Catheter-associated urinary tract infections (CAUTIs) are among the most common health care-associated infections in the United States, yet little is known about the prevention and epidemiology of pediatric CAUTIs. An observational study was conducted to assess the impact of a CAUTI quality improvement prevention bundle that included institution-wide standardization of and training on urinary catheter insertion and maintenance practices, daily review of catheter necessity, and rapid review of all CAUTIs. Poisson regression was used to determine the impact of the bundle on CAUTI rates. A retrospective cohort study was performed to describe the epidemiology of incident pediatric CAUTIs at a tertiary care children's hospital over a 3-year period (June 2009 to June 2012). Implementation of the CAUTI prevention bundle was associated with a 50% reduction in the mean monthly CAUTI rate (95% confidence interval: -1.28 to -0.12; P = .02) from 5.41 to 2.49 per 1000 catheter-days. The median monthly catheter utilization ratio remained unchanged; ∼90% of patients had an indication for urinary catheterization. Forty-four patients experienced 57 CAUTIs over the study period. Most patients with CAUTIs were female (75%), received care in the pediatric or cardiac ICUs (70%), and had at least 1 complex chronic condition (98%). Nearly 90% of patients who developed a CAUTI had a recognized indication for initial catheter placement. CAUTI is a common pediatric health care-associated infection. Implementation of a prevention bundle can significantly reduce CAUTI rates in children. Copyright © 2014 by the American Academy of Pediatrics.

  10. Evaluation of a respiratory assist catheter that uses an impeller within a hollow fiber membrane bundle.

    Science.gov (United States)

    Mihelc, Kevin M; Frankowski, Brian J; Lieber, Samuel C; Moore, Nathan D; Hattler, Brack G; Federspiel, William J

    2009-01-01

    Respiratory assist using an intravenous catheter may be a potential treatment for patients suffering from acute or acute-on-chronic lung failure. The objective of this study was to evaluate a novel respiratory catheter that uses an impeller within the fiber bundle to enhance gas exchange efficiency, thus requiring a smaller fiber bundle and insertional size (25 Fr) and permitting simple percutaneous insertion. Bench testing of gas exchange in deionized water was used to evaluate eight impeller designs. The three best performing impeller designs were evaluated in acute studies in four calves (122 + or - 10 kg). Gas exchange increased significantly with increasing impeller rotation rate. The degree of enhancement varied with impeller geometry. The maximum gas exchange efficiency (exchange per unit surface area) for the catheter with the best performing impeller was 529 + or - 20 ml CO(2)/min/m(2) and 513 + or - 21 ml CO(2)/min/m(2) for bench and animal studies, respectively, at a rotation rate of 20,000 rpm. Absolute CO(2) exchange was 37 and 36 ml CO(2)/min, respectively. Active mixing by rotating impellers produced 70% higher gas exchange efficiency than pulsating balloon catheters. The sensitivity of gas exchange to impeller design suggests that further improvements can be made by computational fluid dynamics-based optimization of the impeller.

  11. Percutaneous central venous catheters versus peripheral cannulae for delivery of parenteral nutrition in neonates.

    Science.gov (United States)

    Ainsworth, S B; Clerihew, L; McGuire, W

    2007-07-18

    Parenteral nutrition for neonates may be delivered via a short peripheral cannula or a central venous catheter. The latter may either be inserted via the umbilicus or percutaneously. Because of the complications associated with umbilical venous catheter use, many neonatal units prefer to use percutaneously inserted catheters following the initial stabilisation period. The method of parenteral nutrition delivery may affect nutrient input and consequently growth and development. Although potentially more difficult to place, percutaneous central venous catheters may be more stable than peripheral cannulae, and need less frequent replacement. These delivery methods may also be associated with different risks of adverse events, including acquired systemic infection and extravasation injury. To determine the effect of infusion via a percutaneous central venous catheter versus a peripheral cannula on nutrient input, growth and development, and complications including systemic infection, or extravasation injuries in newborn infants who require parenteral nutrition. The standard search strategy of the Cochrane Neonatal Review Group was used. This included searches of the Cochrane Central Register of Controlled Trials (CENTRAL, The Cochrane Library, Issue 1, 2007), MEDLINE (1966 - February 2007), EMBASE (1980 - February 2007), conference proceedings, and previous reviews. Randomised controlled trials that compared the effect of delivering parenteral nutrition via a percutaneous central venous catheter versus a peripheral cannulae in neonates. Data were extracted the data using the standard methods of the Cochrane Neonatal Review Group, with separate evaluation of trial quality and data extraction by each author, and synthesis of data using relative risk, risk difference and mean difference. Four trials eligible for inclusion were found. These trials recruited a total of 368 infants and reported a number of different outcomes. One study showed that the use of a percutaneous

  12. Factors associated with the quality of life of adults subjected to hemodialysis in a city in northeast Brazil.

    Science.gov (United States)

    Cavalcante, Milady Cutrim Vieira; Lamy, Zeni Carvalho; Lamy Filho, Fernando; França, Ana Karina Teixeira da Cunha; dos Santos, Alcione Miranda; Thomaz, Erika Bárbara Abreu Fonseca; da Silva, Antonio Augusto Moura; Salgado Filho, Natalino

    2013-01-01

    There is a known association between low scores for quality of life (QOL) and higher rates of hospitalization, mortality in hemodialysis vascular access catheter, older age, lack of regular occupation, presence of comorbidities and hypoalbuminemia. There is still no agreement about the influence of sex, educational level, socioeconomic status and treatment time on the worst levels of QOL. Identify socioeconomic, demographic, clinical, nutritional and laboratory factors associated with worse QOL in adults undergoing hemodialysis in Sao Luís, Maranhão, Brazil. A cross-sectional study which evaluated the QOL of patients with chronic renal disease, aged 20-59 years, undergoing hemodialysis. Two instruments were used: the Kidney Disease Quality of Life -Short Form 1.3 (KDQOL-SF™ 1.3) and a questionnaire on socioeconomic, demographic, clinical, nutritional and laboratory data. The reliability of KDQOL-SF™ 1.3 was assessed by Cronbach's alpha. For the multivariable analysis a Poisson regression model with robust adjustment of the standard error was used. The reliability assessment of KDQOL-SF™ 1.3 showed a Cronbach's alpha test greater than 0.8 in all areas. The areas with the worst levels of QOL were "work situation", "burden of kidney disease", "patient satisfaction", "physical function" and "general health". Having less than 8 years of schooling, coming from the countryside and having cardiovascular disease were associated to the areas with the worst levels of QOL. KDQOL-SF™ 1.3 is a reliable instrument to measure quality of life of hemodialysis patients. Demographic and clinical conditions can negatively influence QOL in chronic renal failure patients.

  13. Home hemodialysis

    DEFF Research Database (Denmark)

    Agar, John W; Perkins, Anthony; Heaf, James G

    2015-01-01

    We describe the infrastructure that is necessary for hemodialysis in the home focusing on physical requirements, the organization of plumbing and water, and the key features that should guide the selection of machines that are suitable for home use.......We describe the infrastructure that is necessary for hemodialysis in the home focusing on physical requirements, the organization of plumbing and water, and the key features that should guide the selection of machines that are suitable for home use....

  14. Pre-puncture ultrasound guided epidural insertion before vaginal delivery.

    Science.gov (United States)

    Nassar, Mahmoud; Abdelazim, Ibrahim A

    2015-10-01

    Palpation method is widely used in clinical practice to identify the puncture site during combined spinal-epidural (CSE) blocks. Tuffier's line, is an anatomical landmark between two iliac crests (inter-cristal), which is widely used to identify the puncture site during CSE blocks is not always an indicator for specific vertebral level or inter-vertebral space. One hundred and Ten (110) women were scheduled for normal vaginal delivery and were randomized into two equal groups; palpation group and an ultrasound guided group to detect the efficacy of puncture ultrasound before CSE blocks to increase chances of successful CSE procedure on the first attempt and to reduce the number of attempts or punctures during insertion of CSE catheter. There were no significant differences between two studied groups regarding; maternal age, weight and height, while, there was a significant difference between two studied groups regarding; parity. Percentage of successful CSE procedure on the first attempt was significantly higher (67.27%) in ultrasound compared to palpation group (40%). Number of punctures (attempts) were significantly less in ultrasound (1.2 ± 0.6) compared to palpation group (2.3 ± 0.8) and the number of redirections was also significantly less in ultrasound (1.4 ± 0.5) compared to palpation group (2.8 ± 1.6). Although, time to identify puncture site was significantly longer in ultrasound compared to palpation group and total procedure time was longer in ultrasound (9.1 ± 1.5 min) compared to palpation group (6.2 ± 1.2 min), there was no significant difference between two studied groups regarding; time to identify puncture site and total procedure time. Two cases of dural puncture in palpation versus no cases in ultrasound group and two cases of intravascular catheter placement (one in each group), with no significant difference between two groups. Pre- puncture ultrasound guided epidural insertion before vaginal delivery, increases the chance of a

  15. An experimental comparative study of radiography, ultrasonography and CT imaging in the IV catheter fragment

    International Nuclear Information System (INIS)

    Kweon, Dae Cheol

    2016-01-01

    The objective of this study was to detect the fragments generated during IV (intravenous) catheter injection of contrast medium and drug administration in a clinical setting and removal was performed by experimentally producing a phantom, and to compare the radiography, ultrasonography, and multi-detector computed tomography (MDCT) imaging and radiation dose. A 1 cm fragment of an 18 gage Teflon® IV catheter with saline was inserted into the IV control line. Radiography, CT, and ultrasonography were performed and radiography and CT dose were calculated. CT and ultrasonography showed an IV catheter fragment clinically and radiography showed no visible difference in the ability to provide a useful image of an IV catheter fragment modality (p >.05). Radiography of effective dose (0.2139 mSv·Gy-1·cm-2) form DAP DAP (0.93 μGy·m2 ), and dose length product (DLP) (201 mGy·cm) to effective dose was calculated as 0.483 mSv. IV catheter fragment were detected of radiography, ultrasonography and CT. These results can be obtained by menas of an excellent IV catheter fragment of detection capability CT. However, CT is followed by radiation exposure. IV catheter fragment confirming the position and information recommend an ultrasonography

  16. Catheter ablation as a treatment of atrioventricular block.

    Science.gov (United States)

    Tuohy, Stephen; Saliba, Walid; Pai, Manjunath; Tchou, Patrick

    2018-01-01

    Symptomatic second-degree atrioventricular (AV) block is typically treated by implantation of a pacemaker. An otherwise healthy AV conduction system can nevertheless develop AV block due to interference from junctional extrasystoles. When present with a high burden, these can produce debilitating symptoms from AV block despite an underlying normal AV node and His-Purkinje system properties. The purpose of this study was to describe a catheter ablation approach for alleviating symptomatic AV block due to a ventricular nodal pathway interfering with AV conduction. Common clinical monitoring techniques such as Holter and event recorders were used. Standard electrophysiological study techniques using multipolar recording and ablation catheters were utilized during procedures. A 55-year-old woman presented with highly symptomatic, high-burden second-degree AV block due to concealed and manifest junctional premature beats. Electrophysiological characteristics indicated interference of AV conduction due to a concealed ventricular nodal pathway as the cause of the AV block. The patient's AV nodal and His-Purkinje system conduction characteristics were otherwise normal. Radiofrequency catheter ablation of the pathway was successful in restoring normal AV conduction and eliminating her clinical symptoms. Pathways inserting into the AV junction can interfere with AV conduction. When present at a high burden, this type of AV block can be highly symptomatic. Catheter ablation techniques can be used to alleviate this type of AV block and restore normal AV conduction. Copyright © 2017 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  17. Hemodialysis: stressors and coping strategies.

    Science.gov (United States)

    Ahmad, Muayyad M; Al Nazly, Eman K

    2015-01-01

    End-stage renal disease (ESRD) is an irreversible and life-threatening condition. In Jordan, the number of ESRD patients treated with hemodialysis is on the rise. Identifying stressors and coping strategies used by patients with ESRD may help nurses and health care providers to gain a clearer understanding of the condition of these patients and thus institute effective care planning. The purpose of this study was to identify stressors perceived by Jordanian patients on hemodialysis, and the coping strategies used by them. A convenience sample of 131 Jordanian men and women was recruited from outpatients' dialysis units in four hospitals. Stressors perceived by participants on hemodialysis and the coping strategies were measured using Hemodialysis Stressor Scale, and Ways of Coping Scale-Revised. Findings showed that patients on hemodialysis psychosocial stressors scores mean was higher than the physiological stressors mean. Positive reappraisal coping strategy had the highest mean among the coping strategies and the lowest mean was accepting responsibility. Attention should be focused towards the psychosocial stressors of patients on hemodialysis and also helping patients utilize the coping strategies that help to alleviate the stressors. The most used coping strategy was positive reappraisal strategy which includes faith and prayer.

  18. A new device for the prevention of pulmonary embolism in critically ill patients: Results of the European Angel Catheter Registry.

    Science.gov (United States)

    Taccone, Fabio S; Bunker, Nicholas; Waldmann, Carl; De Backer, Daniel; Brohi, Karim; Jones, Robert G; Vincent, Jean-Louis

    2015-09-01

    Pulmonary embolism (PE) is a potentially life-threatening complication of critical illness. In trauma and neurosurgical patients with contraindications to anticoagulation, inferior vena cava (IVC) filters have been used to prevent PE, but their associated long-term complication rates and difficulties associated with filter removal have limited their use. The Angel catheter is a temporary device, which combined an IVC filter with a triple-lumen central venous catheter (IVC filter-catheter) and is intended for bedside placement and removal when no longer indicated. This study presents data from a European Registry of 60 critically ill patients in whom the IVC filter-catheter was used to prevent PE. The patients were all at high risk of PE development or recurrence and had contraindications to anticoagulation. The primary end points of this study were to evaluate the safety (in particular, the presence of infectious or thrombotic events) and effectiveness (the numbers of PEs and averted PEs) of the IVC filter-catheter. The main diagnosis before catheter insertion was major trauma in 33 patients (55%), intracerebral hemorrhage or stroke in 9 (15%), a venous thromboembolic event in 9 (15%), and active bleeding in 6 (10%). The IVC filter-catheter was placed as prophylaxis in 51 patients (85%) and as treatment in the 9 patients (15%) with venous thromboembolic event. The devices were inserted at the bedside without fluoroscopic guidance in 54 patients (90%) and within a median of 4 days after hospital admission. They were left in place for a mean of 6 days (4-8 days). One patient developed a PE, without hemodynamic compromise; two PEs were averted. No serious adverse events were reported. Early bedside placement of an IVC filter-catheter is possible, and our results suggest that this is a safe, effective alternative to short-term PE prophylaxis for high-risk patients with contraindications to anticoagulation. Therapeutic study, level V.

  19. Epidemiology of peritonitis following maintenance peritoneal dialysis catheter placement during infancy: a report of the SCOPE collaborative.

    Science.gov (United States)

    Zaritsky, Joshua Jacob; Hanevold, Coral; Quigley, Raymond; Richardson, Troy; Wong, Cynthia; Ehrlich, Jennifer; Lawlor, John; Rodean, Jonathan; Neu, Alicia; Warady, Bradley A

    2018-04-01

    Maintenance peritoneal dialysis (PD) is the dialysis modality of choice for infants and young children. However, there are limited outcome data for those who undergo PD catheter insertion and initiate maintenance PD within the first year of life. Using data from the Children's Hospital Association's Standardizing Care to Improve Outcomes in Pediatric End Stage Renal Disease (ESRD) Collaborative (SCOPE), we examined peritonitis rates and patient survival in 156 infants from 29 North American pediatric dialysis centers who had a chronic PD catheter placed prior to their first birthday. In-hospital and overall annualized rates of peritonitis were 1.73 and 0.76 episodes per patient-year, respectively. Polycystic kidney disease was the most frequent renal diagnosis and pulmonary hypoplasia the most common co-morbidity in infants with peritonitis. Multivariable regression models demonstrated that nephrectomy at or prior to PD catheter placement and G-tube insertion after catheter placement were associated with a nearly sixfold and nearly threefold increased risk of peritonitis, respectively. Infants with peritonitis had longer initial hospital stays and lower overall survival (86.3 vs. 95.6%, respectively; P high and several risk factors associated with the development of peritonitis were identified. Given that peritonitis was associated with a longer duration of initial hospitalization and increased mortality, increased attention to the potentially modifiable risk factors for infection is needed.

  20. Bicytopenia, especially thrombocytopenia in hemodialysis and non-hemodialysis patients treated with linezolid therapy.

    Science.gov (United States)

    Kato, Hideo; Hamada, Yukihiro; Hagihara, Mao; Hirai, Jun; Yamagishi, Yuka; Matsuura, Katsuhiko; Mikamo, Hiroshige

    2015-10-01

    One of the major adverse events associated with linezolid treatment is pancytopenia. However, there are few reports about the tolerability of linezolid among patients undergoing hemodialysis. This study retrospectively investigated the frequency of bicytopenia (thrombocytopenia and erythropenia) secondary to linezolid treatment in patients undergoing and not-undergoing hemodialysis. In total, 181 patients treated with linezolid from January 2010 to July 2012 at Aichi Medical University Hospital were divided into three groups; patients undergoing hemodialysis (HD group), those with creatinine clearance (CLCR) of linezolid therapy were compared among three groups. Thrombocytopenia (linezolid therapy. In particular, the PLT nadir in HD group occurred earlier than that in non-HD groups (HD, 11.5 days [4-31 days]; CLCR linezolid treatment in patients undergoing hemodialysis. Copyright © 2015 Japanese Society of Chemotherapy and The Japanese Association for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  1. Sharp Central Venous Recanalization in Hemodialysis Patients: A Single-Institution Experience

    Energy Technology Data Exchange (ETDEWEB)

    Arabi, Mohammad, E-mail: marabi2004@hotmail.com; Ahmed, Ishtiaq; Mat’hami, Abdulaziz [Prince Sultan Military Medical City (PSMMC), Division of Endovascular Interventional Radiology, Department of Medical Imaging (Saudi Arabia); Ahmed, Dildar; Aslam, Naveed [Prince Sultan Military Medical City (PSMMC), Department of Nephrology (Saudi Arabia)

    2016-06-15

    PurposeWe report our institutional experience with sharp central venous recanalization in chronic hemodialysis patients who failed standard techniques.Materials and MethodsSince January 2014, a series of seven consecutive patients (four males and three females), mean age 35 years (18–65 years), underwent sharp central venous recanalization. Indications included obtaining hemodialysis access (n = 6) and restoration of superior vena cava (SVC) patency to alleviate occlusion symptoms and restore fistula function (n = 1). The transseptal needle was used for sharp recanalization in six patients, while it could not be introduced in one patient due to total occlusion of the inferior vena cava. Instead, transmediastinal SVC access using Chiba needle was obtained.ResultsTechnical success was achieved in all cases. SVC recanalization achieved symptoms’ relief and restored fistula function in the symptomatic patient. One patient underwent arteriovenous fistula creation on the recanalized side 3 months after the procedure. The remaining catheters were functional at median follow-up time of 9 months (1–14 months). Two major complications occurred including a right hemothorax and a small hemopericardium, which were managed by covered stent placement across the perforated SVC.ConclusionSharp central venous recanalization using the transseptal needle is feasible technique in patients who failed standard recanalization procedures. The potential high risk of complications necessitates thorough awareness of anatomy and proper technical preparedness.

  2. Sharp Central Venous Recanalization in Hemodialysis Patients: A Single-Institution Experience

    International Nuclear Information System (INIS)

    Arabi, Mohammad; Ahmed, Ishtiaq; Mat’hami, Abdulaziz; Ahmed, Dildar; Aslam, Naveed

    2016-01-01

    PurposeWe report our institutional experience with sharp central venous recanalization in chronic hemodialysis patients who failed standard techniques.Materials and MethodsSince January 2014, a series of seven consecutive patients (four males and three females), mean age 35 years (18–65 years), underwent sharp central venous recanalization. Indications included obtaining hemodialysis access (n = 6) and restoration of superior vena cava (SVC) patency to alleviate occlusion symptoms and restore fistula function (n = 1). The transseptal needle was used for sharp recanalization in six patients, while it could not be introduced in one patient due to total occlusion of the inferior vena cava. Instead, transmediastinal SVC access using Chiba needle was obtained.ResultsTechnical success was achieved in all cases. SVC recanalization achieved symptoms’ relief and restored fistula function in the symptomatic patient. One patient underwent arteriovenous fistula creation on the recanalized side 3 months after the procedure. The remaining catheters were functional at median follow-up time of 9 months (1–14 months). Two major complications occurred including a right hemothorax and a small hemopericardium, which were managed by covered stent placement across the perforated SVC.ConclusionSharp central venous recanalization using the transseptal needle is feasible technique in patients who failed standard recanalization procedures. The potential high risk of complications necessitates thorough awareness of anatomy and proper technical preparedness.

  3. The effectiveness of a nurse-initiated intervention to reduce catheter-associated bloodstream infections in an urban acute hospital: an intervention study with before and after comparison.

    Science.gov (United States)

    Tsuchida, Toshie; Makimoto, Kiyoko; Toki, Masayo; Sakai, Keiko; Onaka, Emiko; Otani, Yoshiko

    2007-11-01

    Catheter care is considered to be important for prevention of catheter-associated bloodstream infections (CABSIs) although epidemiological evidence is sparse. To identify problems associated with catheter care and evaluate the effectiveness of nurse-initiated interventions to reduce CABSIs. An intervention study with before and after comparison. CABSI surveillance was conducted in a 560-bed acute hospital located in a major urban area in Japan. Patients were enrolled in this study from April 2000 to December 2002 based on the following criteria: (1) adult inpatients; and (2) those in whom central venous lines or Swan-Ganz catheters were inserted for 2 days or longer. In the first year, risk factors for CABSI and problems associated with catheter care were identified by inspection of the infection control nurse (ICN) or four trained link nurses, and the laboratory results. In the subsequent 2 years, the following interventions based on the surveillance results were implemented: (1) enhanced skin preparation by scrubbing with regular bathing soap and tap water; (2) a new method for stabilisation of the catheter inserted into the internal jugular vein, where additional dressing was placed over the sterilised dressing; (3) educating the staff on maximal sterile precautions by teaching staff members at their section meetings and displaying posters; (4) use of a check list and observation of catheter insertion by link nurses to monitor compliance; and (5) selection of a disinfectant that requires shorter contact time and has longer residual effect. After these interventions were implemented, the overall bloodstream infection (BSI) rate declined from 4.0/1000 device-days to 1.1/1000 device-days (p<0.005). We identified four problems-those related to skin preparation, dressing, sterile precautions and disinfectant. We implemented a series of interventions to reduce CABSIs; the overall CABSI rate decreased significantly.

  4. The establishment of implanted VX2 liver tumor model in rabbits and discussion on superselective left hepatic arterial catheterization with micro-catheter technique via femoral artery

    International Nuclear Information System (INIS)

    Jiang Xiongying; Luo Rongguang; Huang Jinhua; Miao Bijian; Wang Yan

    2011-01-01

    Objective: To establish the implanted VX2 liver tumor model in rabbits and to discuss the feasibility and technical features of superselective left hepatic arterial catheterization by using micro-catheter through the femoral artery catheter sheath. Methods: Forty New Zealand white rabbits were inoculated with fragments of VX2 tumor into the medial left lobe of liver by using a 16G lumbar puncture needle through laparotomy route. Two weeks later, all the rabbits were proved to be successfully inoculated with liver neoplasm on CT scanning. Then, the catheter sheath was inserted into one of the femoral arteries, which was followed by celiac artery angiography and left hepatic artery catheterization with a micro-catheter under DSA guidance in order to evaluate the main branches of celiac artery and the imaging manifestations of VX2 liver tumor. After that, some scheduled interventional experiments were carried out. Results: Imaging examination and histopathologic study showed that the successful rate of implanted rabbit VX2 liver tumor was 100% (40/40). And the successful rate of the catheter sheath inserted to femoral artery was 97.5% (39/40). The successful rate of celiac artery, gastro-hepatic artery, common hepatic artery, proper hepatic artery and left hepatic artery catheterizations was 100% (39/39), 100% (39/39), 100% (39/39), 94.9% (37/39) and 71.2% (28/39) respectively. Conclusion: To implant tumor tissue mass through laparotomy is a stable and reliable method to establish rabbit VX2 liver tumor model. The insertion of micro-catheter through rabbit femoral catheter sheath approach is a convenient and simple technique to be carried out for the left hepatic artery catheterization and it can efficiently solve the technical difficulties when performing the interventional treatment of the rabbit VX2 hepatic tumor via left hepatic artery approach. (authors)

  5. Changes in Plasma Copeptin Levels during Hemodialysis: Are the Physiological Stimuli Active in Hemodialysis Patients?

    Directory of Open Access Journals (Sweden)

    Esmée M Ettema

    Full Text Available Plasma levels of copeptin, a surrogate marker for the vasoconstrictor hormone arginine vasopressin (AVP, are increased in hemodialysis patients. Presently, it is unknown what drives copeptin levels in hemodialysis patients. We investigated whether the established physiological stimuli for copeptin release, i.e. plasma osmolality, blood volume and mean arterial pressure (MAP, are operational in hemodialysis patients.One hundred and eight prevalent, stable hemodialysis patients on a thrice-weekly dialysis schedule were studied during hemodialysis with constant ultrafiltration rate and dialysate conductivity in this observational study. Plasma levels of copeptin, sodium, MAP, and blood volume were measured before, during and after hemodialysis. Multivariate analysis was used to determine the association between copeptin (dependent variable and the physiological stimuli plasma sodium, MAP, excess weight as well as NT-pro-BNP immediately prior to dialysis and between copeptin and changes of plasma sodium, MAP and blood volume with correction for age, sex and diabetes during dialysis treatment.Patients were 63 ± 15.6 years old and 65% were male. Median dialysis vintage was 1.6 years (IQR 0.7-4.0. Twenty-three percent of the patients had diabetes and 82% had hypertension. Median predialysis copeptin levels were 141.5 pmol/L (IQR 91.0-244.8 pmol/L. Neither predialysis plasma sodium levels, nor NT-proBNP levels, nor MAP were associated with predialysis copeptin levels. During hemodialysis, copeptin levels rose significantly (p<0.01 to 163.0 pmol/L (96.0-296.0 pmol/L. Decreases in blood volume and MAP were associated with increases in copeptin levels during dialysis, whereas there was no significant association between the change in plasma sodium levels and the change in copeptin levels.Plasma copeptin levels are elevated predialysis and increase further during hemodialysis. Volume stimuli, i.e. decreases in MAP and blood volume, rather than osmotic

  6. Magnetic resonance imaging guided transatrial electrophysiological studies in swine using active catheter tracking - experience with 14 cases

    Energy Technology Data Exchange (ETDEWEB)

    Grothoff, Matthias; Gutberlet, Matthias [University of Leipzig - Heart Center, Department of Radiology, Leipzig (Germany); Hindricks, Gerhard; Sommer, Philipp; Hilbert, Sebastian [University of Leipzig - Heart Center, Department of Electrophysiology, Leipzig (Germany); Fleiter, Christian [Helios Klinikum Berlin-Buch, Department of Orthopaedic Surgery, Berlin (Germany); Schnackenburg, Bernhard [Philips Healthcare, Hamburg (Germany); Weiss, Steffen; Krueger, Sascha [Philips Innovative Technologies, Hamburg (Germany); Piorkowski, Christopher; Gaspar, Thomas [University of Dresden - Heart Center, Department of Electrophysiology, Dresden (Germany); Wedan, Steve; Lloyd, Thomas [Imricor Medical Systems, Burnsville, MN (United States)

    2017-05-15

    To evaluate the feasibility of performing comprehensive Cardiac Magnetic resonance (CMR) guided electrophysiological (EP) interventions in a porcine model encompassing left atrial access. After introduction of two femoral sheaths 14 swine (41 ± 3.6 kg) were transferred to a 1.5 T MR scanner. A three-dimensional whole-heart sequence was acquired followed by segmentation and the visualization of all heart chambers using an image-guidance platform. Two MR conditional catheters were inserted. The interventional protocol consisted of intubation of the coronary sinus, activation mapping, transseptal left atrial access (n = 4), generation of ablation lesions and eventually ablation of the atrioventricular (AV) node. For visualization of the catheter tip active tracking was used. Catheter positions were confirmed by passive real-time imaging. Total procedure time was 169 ± 51 minutes. The protocol could be completed in 12 swine. Two swine died from AV-ablation induced ventricular fibrillation. Catheters could be visualized and navigated under active tracking almost exclusively. The position of the catheter tips as visualized by active tracking could reliably be confirmed with passive catheter imaging. Comprehensive CMR-guided EP interventions including left atrial access are feasible in swine using active catheter tracking. (orig.)

  7. Catheter Angiography

    Medline Plus

    Full Text Available ... of a catheter makes it possible to combine diagnosis and treatment in a single procedure. Catheter angiography ... of a catheter makes it possible to combine diagnosis and treatment in a single procedure. An example ...

  8. Ultrasound-guided pigtail catheters for drainage of various pleural diseases.

    Science.gov (United States)

    Liu, Yi-Heng; Lin, Yu-Chao; Liang, Shinn-Jye; Tu, Chih-Yen; Chen, Chia-Hung; Chen, Hung-Jen; Chen, Wei; Shih, Chuen-Ming; Hsu, Wu-Huei

    2010-10-01

    Little is known about the efficacy and safety of ultrasound-guided pigtail catheters for the management of various pleural diseases in the emergency department, ward, and intensive care unit. We conducted a retrospective study in a university hospital during a 1-year interval. A total of 276 patients (178 men and 98 women) underwent 332 pigtail catheters (the drain size ranged from 10F to 16F) under ultrasound guidance. The mean ± SEM patient age was 59 ± 18 years, and mean duration of drainage was 6.1 ± 2 days. A total of 64 drains (19.2%) were inserted for pneumothoraces; 98 drains (29.5%), for malignant effusions; 119 drains (35.8%), for parapneumonic effusions/empyemas; and 38 drains (11.4%), for massive transudate pleural effusions. The overall success rate was 72.9%. The success rate was highest when the drain was used to treat massive transudate effusions (81.6%) and malignant pleural effusions (75.5%), followed by parapneumonic effusions/empyemas (72.2%), hemothoraces (66.6%), and pneumothoraces (64.0%). Only 10 (3.0%) drains had complications due to the procedure, including infection (n = 4, 1.2%), dislodgment (n = 4, 1.2%), wound bleeding at the pigtail catheter puncture area complicated with hemothoraces (n = 1, 0.3%), and lung puncture (n = 1, 0.3%). There was no significant difference in success rate when different catheter sizes were used to treat pleural diseases. Ultrasound-guided pigtail catheters provide a safe and effective method of draining various pleural diseases. We strongly suggest that ultrasound-guided pigtail catheters be considered as the initial draining method for a variety of pleural diseases. Copyright © 2010 Elsevier Inc. All rights reserved.

  9. Catheter Angiography

    Medline Plus

    Full Text Available ... using: x-rays with catheters computed tomography (CT) magnetic resonance imaging (MRI) In catheter angiography, a thin plastic ... called superselective angiography. Unlike computed tomography (CT) or magnetic resonance (MR) angiography , use of a catheter makes it ...

  10. Removing Nasal Packing in Epistaxis: What to Do in the Case of an Undeflatable Foley Catheter Balloon

    Directory of Open Access Journals (Sweden)

    Gaspar-Sobrinho, Fernando Pena

    2014-01-01

    Full Text Available Introduction Undeflatable Foley catheter balloons adapted for use as nasal packing in epistaxis represent a possible complication. Case Reports We report on three cases in which Foley catheter balloons adapted for use as posterior nasal packing in epistaxis failed to deflate. In one patient, deflation was achieved by simply using the fingertips to massage the segment of the catheter collapsed by the fixation device. In the second case, the Foley balloon was removed by the oral route after sectioning the catheter. In the third patient, the Foley catheter was successfully deflated after sectioning. Discussion The probable causes of the undeflatable balloons in these cases were a blockage or lumen collapse of the balloon or a malfunction in the valve system. Although no definitive method has been established for dealing with this complication, the options proposed are the following: manipulation to restore the permeability of the segment of the catheter collapsed by the fixation device, if this is the case; sectioning the catheter or inserting a stiletto catheter; bursting the balloon; or removing it by the oral route. The latter option is apparently the most appropriate for the otolaryngologist in cases unrelated to simple collapse caused by the fixation device.

  11. Hospitalization in daily home hemodialysis and matched thrice-weekly in-center hemodialysis patients.

    Science.gov (United States)

    Weinhandl, Eric D; Nieman, Kimberly M; Gilbertson, David T; Collins, Allan J

    2015-01-01

    Cardiovascular disease is a common cause of hospitalization in dialysis patients. Daily hemodialysis improves some parameters of cardiovascular function, but whether it associates with lower hospitalization risk is unclear. Observational cohort study using US Renal Data System data. Medicare-enrolled daily (5 or 6 sessions weekly) home hemodialysis (HHD) patients initiating NxStage System One use from January 1, 2006, through December 31, 2009, and contemporary thrice-weekly in-center hemodialysis patients, matched 5 to 1. Daily HHD or thrice-weekly in-center hemodialysis. All-cause and cause-specific hospital admissions, hospital readmissions, and hospital days assessed from Medicare Part A claims. For 3,480 daily HHD and 17,400 thrice-weekly in-center hemodialysis patients in intention-to-treat analysis, the HR of all-cause admission for daily HHD versus in-center hemodialysis was 1.01 (95%CI, 0.98-1.03). Cause-specific admission HRs were 0.89 (95%CI, 0.86-0.93) for cardiovascular disease, 1.18 (95%CI, 1.13-1.23) for infection, 1.01 (95%CI, 0.93-1.09) for vascular access dysfunction, and 1.02 (95%CI, 0.99-1.06) for other morbidity. Regarding cardiovascular disease, first admission and readmission HRs for daily HHD versus in-center hemodialysis were 0.91 and 0.87, respectively. Regarding infection, first admission and readmission HRs were 1.35 and 1.03, respectively. Protective associations of daily HHD with heart failure and hypertensive disease were most pronounced, as were adverse associations of daily HHD with bacteremia/sepsis, cardiac infection, osteomyelitis, and vascular access infection. Results may be confounded by unmeasured factors, including vascular access type; information about dialysis frequency, duration, and dose was lacking; causes of admission may be misclassified; results may not apply to patients without Medicare coverage. All-cause hospitalization risk was similar in daily HHD and thrice-weekly in-center hemodialysis patients. However

  12. Dialyzability of gadodiamide in hemodialysis patients

    International Nuclear Information System (INIS)

    Saitoh, Tomoya; Tanaka, Yoshiaki; Kuno, Tsutomu; Nagura, Yuji; Hayasaka, Kazumasa

    2006-01-01

    The aim of this study was to evaluate the contrast enhancement, pharmacokinetics, dialyzability, and safety of gadodiamide in patients on hemodialysis. Thirteen hemodialysis patients with abdominal disease were examined after receiving intravenous gadodiamide (0.1 mmol/kg body weight) by magnetic resonance imaging (MRI) and were dialyzed at 1, 3, 5, and 8 days. Blood samples were obtained immediately before, during, and at the end of the first hemodialysis session and immediately before and at the end of the next three sessions. The complete blood count, blood biochemistry, β 2 -microglobulin, and gadolinium were measured. Dialysis of urea, creatinine, and gadolinium during the first hemodialysis session was assessed. Precontrast and postcontrast MRI and Gd-enhanced MR angiography (MRA) images were reviewed and visually evaluated by two radiologists; their evaluation was based on consensus. Gadodiamide did not cause any changes in renal function. An average of 73.8%, 92.4%, and 98.9% of the gadodiamide dose was eliminated by the end of the first, second, and third hemodialysis sessions, respectively. The average half-time of gadodiamide was 1.93 h (SD 0.55). The mean clearance of gadodiamide during hemodialysis was 63.5 ml/min (SD 21.9). There were no side effects related to the injection of gadodiamide. In all cases, diagnosable MRI and MRA images were obtained after gadodiamide injection in the hemodialysis patients. In hemodialysis patients, gadodiamide achieves diagnosable images. It is dialyzable and can be used safely without measures to increase excretion. (author)

  13. Detection of an embolized central venous catheter fragment with endobronchial ultrasound.

    Science.gov (United States)

    Dhillon, Samjot Singh; Harris, Kassem; Alraiyes, Abdul H; Picone, Anthony L

    2018-01-01

    An 84-year-old woman underwent Convex-probe Endobronchial Ultrasound (CP-EBUS) for 18 F-fluorodeoxyglucose avid subcarinal lymphadenopathy on Positron Emission Tomogram (PET) scan. Endobronchial ultrasound-guided transbronchial needle aspiration of the subcarinal lymph node revealed squamous cell lung carcinoma. A small hyperechoic rounded density was noted inside the lumen of the azygous vein. Based on chest computed tomography findings and her clinical history, this was felt to be a broken fragment of a peripherally inserted central catheter, which was placed for intravenous antibiotics, a few months prior to this presentation. To the best of our knowledge, this is the first ever CP-EBUS description of a broken fragment of central venous catheter. © 2016 John Wiley & Sons Ltd.

  14. Incremental short daily home hemodialysis: a case series

    OpenAIRE

    Toth-Manikowski, Stephanie M.; Mullangi, Surekha; Hwang, Seungyoung; Shafi, Tariq

    2017-01-01

    Background Patients starting dialysis often have substantial residual kidney function. Incremental hemodialysis provides a hemodialysis prescription that supplements patients? residual kidney function while maintaining total (residual + dialysis) urea clearance (standard Kt/Vurea) targets. We describe our experience with incremental hemodialysis in patients using NxStage System One for home hemodialysis. Case presentation From 2011 to 2015, we initiated 5 incident hemodialysis patients on an ...

  15. Catheter indwell time and phlebitis development during peripheral intravenous catheter administration.

    Science.gov (United States)

    Pasalioglu, Kadriye Burcu; Kaya, Hatice

    2014-07-01

    Intravenous catheters have been indispensable tools of modern medicine. Although intravenous applications can be used for a multitude of purposes, these applications may cause complications, some of which have serious effects. Of these complications, the most commonly observed is phlebitis. This study was conducted to determine the effect of catheter indwell time on phlebitis development during peripheral intravenous catheter administration. This study determined the effect of catheter indwell time on phlebitis development during peripheral intravenous catheter administration. The study included a total of 103 individuals who were administered 439 catheters and satisfied the study enrollment criteria at one infectious diseases clinic in Istanbul/Turkey. Data were compiled from Patient Information Forms, Peripheral Intravenous Catheter and Therapy Information Forms, reported grades based on the Visual Infusion Phlebitis Assessment Scale, and Peripheral Intravenous Catheter Nurse Observation Forms. The data were analyzed using SPSS. Results : The mean patient age was 53.75±15.54 (standard deviation) years, and 59.2% of the study participants were men. Phlebitis was detected in 41.2% of peripheral intravenous catheters, and the rate decreased with increased catheter indwell time. Analyses showed that catheter indwell time, antibiotic usage, sex, and catheterization sites were significantly associated with development of phlebitis. The results of this study show that catheters can be used for longer periods of time when administered under optimal conditions and with appropriate surveillance.

  16. Anterior ischemic optic neuropathy in patients undergoing hemodialysis

    NARCIS (Netherlands)

    DoorenbosBot, ACC; Geerlings, W; Houtman, IA

    Four patients are discussed who underwent hemodialysis and developed anterior ischemic optic neuropathy (AION). Three patients had been treated by hemodialysis for several years. One patient developed bilateral optic neuropathy after the first hemodialysis session, So far, only four hemodialysis

  17. Spurious hypocalcemia in hemodialysis patients after heparinization. In-vitro formation of calcium soaps.

    Science.gov (United States)

    Godolphin, W; Cameron, E C; Frohlich, J; Price, J D

    1979-02-01

    Patients on long-term hemodialysis via arteriovenous fistula received heparin when the fistula needle was inserted, before a sample of blood was obtained for chemical analysis. The resultant release of lipoprotein lipase activity in vivo and continued lipolytic activity in vitro sometimes produced sufficient free fatty acid to precipitate calcium soaps. The consequent spurious hypocalcemia was most frequently observed when the patients had chylomicronemia. This cause of apparent hypocalcemia was eliminated either by immediate analyses of the blood samples or by obtaining samples before systemic heparinization.

  18. Evaluation of electrical nerve stimulation for epidural catheter positioning in the dog.

    Science.gov (United States)

    Garcia-Pereira, Fernando L; Sanders, Robert; Shih, Andre C; Sonea, Ioana M; Hauptman, Joseph G

    2013-09-01

    To evaluate the accuracy of epidural catheter placement at different levels of the spinal cord guided solely by electrical nerve stimulation and resultant segmental muscle contraction. Prospective, experiment. Six male and two female Beagles, age (1 ± 0.17 years) and weight (12.9 ± 1.1 kg). Animals were anesthetized with propofol and maintained with isoflurane. An insulated epidural needle was used to reach the lumbosacral epidural space. A Tsui epidural catheter was inserted and connected to a nerve stimulator (1.0 mA, 0.1 ms, 2 Hz) to assess positioning of the tip at specific spinal cord segments. The catheter was advanced to three different levels of the spinal cord: lumbar (L2-L5), thoracic (T5-T10) and cervical (C4-C6). Subcutaneous needles were previously placed at these spinal levels and the catheter was advanced to match the needle location, guided only by corresponding muscle contractions. Catheter position was verified by fluoroscopy. If catheter tip and needle were at the same vertebral body a score of zero was assigned. When catheter tip was cranial or caudal to the needle, positive or negative numbers, respectively, corresponding to the number of vertebrae between them, were assigned. The mean and standard deviation of the number of vertebrae between catheter tip and needle were calculated to assess accuracy. Results are given as mean ± SD. The catheter position in relation to the needle was within 0.3 ± 2.0 vertebral bodies. Positive predictive values (PPV) were 57%, 83% and 71% for lumbar, thoracic and cervical regions respectively. Overall PPV was 70%. No significant difference in PPV among regions was found. Placement of an epidural catheter at specific spinal levels using electrical nerve stimulation was feasible without radiographic assistance in dogs. Two vertebral bodies difference from the target site may be clinically acceptable when performing segmental epidural regional anesthesia. © 2013 Association of Veterinary

  19. Intra-operative placement of catheters for interstitial microwave-induced hyperthermia and iridium brachytherapy

    International Nuclear Information System (INIS)

    Coughlin, C.T.; Wong, T.Z.; Strohbehn, J.W.; Colacchio, T.A.; Belch, R.Z.; Sutton, J.E. Jr.; Douple, E.B.

    1984-01-01

    The authors have previously described a system for delivery of microwave-induced hyperthermia utilizing flexible coaxial cables that are modified to serve as microwave antennas. These small (--1.6mm o.d.) antennas ae introduced into 2mm o.d. nylon catheters implanted in the tumor. This system has been further modified for use in the treatment of surgically unresectible abdominal, pelvic, and head and neck tumors. The modifications are described that were used to treat two pelvic, one upper abdominal, and one base of tongue tumor. The nylon catheters are implanted during surgery. After a short recovery period, the microwave antennas are inserted and the tumor region is heated for --1hr. The antennas are removed, iridium-192 seeds are placed in the catheters, 2800 - 5000 rad (CGy) doses are delivered, followed by a 1hr hyperthermia treatment. The temperature distributions and future applications are discussed

  20. Development of a New Coaxial Balloon Catheter System for Balloon-Occluded Retrograde Transvenous Obliteration (B-RTO)

    International Nuclear Information System (INIS)

    Tanoue, Shuichi; Kiyosue, Hiro; Matsumoto, Shunro; Hori, Yuzo; Okahara, Mika; Kashiwagi, Junji; Mori, Hiromu

    2006-01-01

    Purpose. To develop a new coaxial balloon catheter system and evaluate its clinical feasibility for balloon-occluded retrograde transvenous obliteration (B-RTO). Methods. A coaxial balloon catheter system was constructed with 9 Fr guiding balloon catheter and 5 Fr balloon catheter. A 5 Fr catheter has a high flexibility and can be coaxially inserted into the guiding catheter in advance. The catheter balloons are made of natural rubber and can be inflated to 2 cm (guiding) and 1 cm (5 Fr) maximum diameter. Between July 2003 and April 2005, 8 consecutive patients (6 men, 2 women; age range 33-72 years, mean age 55.5 years) underwent B-RTO using the balloon catheter system. Five percent ethanolamine oleate iopamidol (EOI) was used as sclerosing agent. The procedures, including maneuverability of the catheter, amount of injected sclerosing agent, necessity for coil embolization of collateral draining veins, and initial clinical results, were evaluated retrospectively. The occlusion rate was assessed by postcontrast CT within 2 weeks after B-RTO. Results. The balloon catheter could be advanced into the proximal potion of the gastrorenal shunt beyond the collateral draining vein in all cases. The amount of injected EOI ranged from 3 to 34 ml. Coil embolization of the collateral draining vein was required in 2 cases. Complete obliteration of gastric varices on initial follow-up CT was obtained in 7 cases. The remaining case required re-treatment that resulted in complete obstruction of the varices after the second B-RTO. No procedure-related complications were observed. Conclusion. B-RTO using the new coaxial balloon catheter is feasible. Gastric varices can be treated more simply by using this catheter system

  1. Infraclavicular versus axillary nerve catheters: A retrospective comparison of early catheter failure rate.

    Science.gov (United States)

    Quast, Michaela B; Sviggum, Hans P; Hanson, Andrew C; Stoike, David E; Martin, David P; Niesen, Adam D

    2018-05-01

    Continuous brachial plexus catheters are often used to decrease pain following elbow surgery. This investigation aimed to assess the rate of early failure of infraclavicular (IC) and axillary (AX) nerve catheters following elbow surgery. Retrospective study. Postoperative recovery unit and inpatient hospital floor. 328 patients who received IC or AX nerve catheters and underwent elbow surgery were identified by retrospective query of our institution's database. Data collected included unplanned catheter dislodgement, catheter replacement rate, postoperative pain scores, and opioid administration on postoperative day 1. Catheter failure was defined as unplanned dislodging within 24 h of placement or requirement for catheter replacement and evaluated using a covariate adjusted model. 119 IC catheters and 209 AX catheters were evaluated. There were 8 (6.7%) failed IC catheters versus 13 (6.2%) failed AX catheters. After adjusting for age, BMI, and gender there was no difference in catheter failure rate between IC and AX nerve catheters (p = 0.449). These results suggest that IC and AX nerve catheters do not differ in the rate of early catheter failure, despite differences in anatomic location and catheter placement techniques. Both techniques provided effective postoperative analgesia with median pain scores < 3/10 for patients following elbow surgery. Reasons other than rate of early catheter failure should dictate which approach is performed. Copyright © 2018. Published by Elsevier Inc.

  2. A prospective clinical trial to assess peripheral venous catheter-related phlebitis using needleless connectors in a surgery department.

    Science.gov (United States)

    Ronen, Ohad; Shlomo, Fanny; Ben-Adiva, Gila; Edri, Zehava; Shema-Didi, Lilach

    2017-10-01

    The use of intravascular catheters is often complicated by phlebitis, which is associated with increased morbidity and extended duration of hospitalization. We conducted a study to investigate the impact of needleless intravenous access devices on the rate of phlebitis in peripheral venous catheters (PVCs). We prospectively recruited patients in 2 phases. The first group was treated with a regular cap, and the second group was treated with a needleless connector. The incidence of catheter-related phlebitis (CRP) was recorded as the primary end point. A total of 620 PVCs using regular caps were inserted into 340 patients and CRP rates were recorded. In the second phase of the study, 169 PVCs using needleless connectors were inserted into 135 patients. In the group treated with the regular cap, the CRP rate was 60% compared with 7% in the group treated with the needleless cap (P phlebitis had a statistically significant longer mean hospitalization period (P <.001), as were patients in the regular cap group (P <.01). The use of needleless connectors was found to be associated with a significant reduction of CRP in peripheral veins in a surgery department setting. The decreased morbidity resulted in a lower number of catheter replacements and duration of hospitalization. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  3. Needle localization using a moving stylet/catheter in ultrasound-guided regional anesthesia: a feasibility study

    Science.gov (United States)

    Beigi, Parmida; Rohling, Robert

    2014-03-01

    Despite the wide range and long history of ultrasound guided needle insertions, an unresolved issue in many cases is clear needle visibility. A well-known ad hoc technique to detect the needle is to move the stylet and look for changes in the needle appearance. We present a new method to automatically locate a moving stylet/catheter within a stationary cannula using motion detection. We then use this information to detect the needle trajectory and the tip. The differences between the current frame and the previous frame are detected and localized, to minimize the influence of tissue global motions. A polynomial fit based on the detected needle axis determines the estimated stylet shaft trajectory, and the extent of the differences along the needle axis represents the tip. Over a few periodic movements of the stylet including its full insertion into the cannula to the tip, a combination of polynomial fits determines the needle trajectory and the last detected point represents the needle tip. Experiments are conducted in water bath and bovine muscle tissue for several stylet/catheter materials. Results show that a plastic stylet has the best needle shaft and tip localization accuracy in the water bath with RMSE = 0:16 mm and RMSE = 0:51 mm, respectively. In the bovine tissue, the needle tip was best localized with the plastic catheter with RMSE = 0:33 mm. The stylet tip localization was most accurate with the steel stylet, with RMSE = 2:81 mm and the shaft was best localized with the plastic catheter, with RMSE = 0:32 mm.

  4. Simulation training for pediatric residents on central venous catheter placement: a pilot study.

    Science.gov (United States)

    Thomas, Scott M; Burch, Wesley; Kuehnle, Sarah E; Flood, Robert G; Scalzo, Anthony J; Gerard, James M

    2013-11-01

    To assess the effect of simulation training on pediatric residents' acquisition and retention of central venous catheter insertion skills. A secondary objective was to assess the effect of simulation training on self-confidence to perform the procedure. Prospective observational pilot study. Single university clinical simulation center. Pediatric residents, postgraduate years 1-3. Residents participated in a 60- to 90-minute ultrasound-guided central venous catheter simulation training session. Video recordings of residents performing simulated femoral central venous catheter insertions were made before (baseline), after, and at 3-month following training. Three blinded expert raters independently scored the performances using a 24-item checklist and 100-mm global rating scale. At each time point, residents rated their confidence to perform the procedure on a 100-mm scale. Twenty-six residents completed the study. Compared with baseline, immediately following training, median checklist score (54.2% [interquartile range, 40.8-68.8%] vs 83.3% [interquartile range, 70.0-91.7%]), global rating score (8.0 mm [interquartile range, 0.0-64.3 mm] vs 79.5 mm [interquartile range, 16.3-91.7 mm]), success rate (38.5% vs 80.8%), and self-confidence (8.0 mm [interquartile range, 3.8-19.0 mm] vs 52.0 mm [interquartile range, 43.5-66.5 mm]) all improved (p interquartile range, 40.8-68.8%] vs 54.2% [interquartile range, 45.8-80.4%], p = 0.47), global rating score (8.0 mm [interquartile range, 0.0-64.3 mm] vs 35.5 mm [interquartile range, 5.3-77.0], p = 0.62), and success rate (38.5% vs 65.4%, p = 0.35) were similar at 3-month follow-up. Self-confidence, however, remained above baseline at 3-month follow-up (8.0 mm [interquartile range, 3.8-19.0 mm] vs 61.0 mm [interquartile range, 31.5-71.8 mm], p < 0.01). Simulation training improved pediatric residents' central venous catheter insertion procedural skills. Decay in skills was found at 3-month follow-up. This suggests that

  5. IgA antibodies against β2 glycoprotein I in hemodialysis patients are an independent risk factor for mortality.

    Science.gov (United States)

    Serrano, Antonio; García, Florencio; Serrano, Manuel; Ramírez, Elisa; Alfaro, F Javier; Lora, David; de la Cámara, Agustín Gómez; Paz-Artal, Estela; Praga, Manuel; Morales, Jose M

    2012-06-01

    Cardiovascular complications are the most important cause of death in patients on dialysis with end-stage renal disease. Antibodies reacting with β-glycoprotein I seem to play a pathogenic role in antiphospholipid syndrome and stroke and are involved in the origin of atherosclerosis. Here we evaluated the presence of anticardiolipin and anti-β-glycoprotein I antibodies together with other vascular risk factors and their relationship with mortality and cardiovascular morbidity in a cohort of 124 hemodialysis patients prospectively followed for 2 years. Of these, 41 patients were significantly positive for IgA anti-β-glycoprotein I, and the remaining had normal values. At 24 months, overall and cardiovascular mortality and thrombotic events were all significantly higher in patients with high anti-β-glycoprotein I antibodies. Multivariate analysis using Cox regression modeling found that age, hypoalbuminemia, use of dialysis catheters, and IgA β-glycoprotein I antibodies were independent risk factors for death. Thus, IgA antibodies to β-glycoprotein I are detrimental to the clinical outcome of hemodialysis patients.

  6. Observations on the development of the crystalline bacterial biofilms that encrust and block Foley catheters.

    Science.gov (United States)

    Stickler, D J; Morgan, S D

    2008-08-01

    The care of many patients undergoing long-term bladder catheterisation is complicated when the flow of urine through the catheter is blocked by encrustation. The problem results from infection by urease-producing bacteria, especially Proteus mirabilis, and the subsequent formation of crystalline biofilms on the catheter. The aim of this study was to discover how P. mirabilis initiates the development of these crystalline biofilms. The early stages in the formation of the biofilms were observed on a range of Foley catheters in a laboratory model of the catheterised bladder. Scanning electron micrographs revealed that when all-silicone, silicone-coated latex, hydrogel-coated latex, hydrogel/silver-coated latex and nitrofurazone silicone catheters were inserted into bladder models containing P. mirabilis and alkaline urine, their surfaces were rapidly coated with a microcrystalline foundation layer. X-ray microanalysis showed that this material was composed of calcium phosphate. Bacterial colonisation of the foundation layer followed and by 18h the catheters were encrusted by densely populated crystalline P. mirabilis biofilms. These observations have important implications for the development of encrustation-resistant catheters. In the case of silver catheters for example, bacterial cells can attach to the crystalline foundation layer and continue to grow, protected from contact with the underlying silver. If antimicrobials are to be incorporated into catheters to prevent encrustation, it is important that they diffuse into the urine and prevent the rise in pH that triggers crystal formation.

  7. Verification of intravenous catheter placement by auscultation--a simple, noninvasive technique.

    Science.gov (United States)

    Lehavi, Amit; Rudich, Utay; Schechtman, Moshe; Katz, Yeshayahu Shai

    2014-01-01

    Verification of proper placement of an intravenous catheter may not always be simple. We evaluated the auscultation technique for this purpose. Twenty healthy volunteers were randomized for 18G catheter inserted intravenously either in the right (12) or left arm (8), and subcutaneously in the opposite arm. A standard stethoscope was placed over an area approximately 3 cm proximal to the tip of the catheter in the presumed direction of the vein to grade on a 0-6 scale the murmur heard by rapidly injecting 2 mL of NaCl 0.9% solution. The auscultation was evaluated by a blinded staff anesthesiologist. All 20 intravenous injection were evaluated as flow murmurs, and were graded an average 5.65 (±0.98), whereas all 20 subcutaneous injections were evaluated as either crackles or no sound, and were graded an average 2.00 (±1.38), without negative results. Sensitivity was calculated as 95%. Specificity and Kappa could not be calculated due to an empty false-positive group. Being simple, handy and noninvasive, we recommend to use the auscultation technique for verification of the proper placement of an intravenous catheter when uncertain of its position. Data obtained in our limited sample of healthy subjects need to be confirmed in the clinical setting.

  8. Peripherally Inserted Central Catheters (PICCs) and Potential Cost Savings and Shortened Bed Stays In an Acute Hospital Setting.

    LENUS (Irish Health Repository)

    O’Brien, C

    2018-01-01

    Peripheral inserted central catheters (PICCs) have increasingly become the mainstay of patients requiring prolonged treatment with antibiotics, transfusions, oncologic IV therapy and total parental nutrition. They may also be used in delivering a number of other medications to patients. In recent years, bed occupancy rates have become hugely pressurized in many hospitals and any potential solutions to free up beds is welcome. Recent introductions of doctor or nurse led intravenous (IV) outpatient based treatment teams has been having a direct effect on early discharge of patients and in some cases avoiding admission completely. The ability to deliver outpatient intravenous treatment is facilitated by the placement of PICCs allowing safe and targeted treatment of patients over a prolonged period of time. We carried out a retrospective study of 2,404 patients referred for PICCs from 2009 to 2015 in a university teaching hospital. There was an exponential increase in the number of PICCs requested from 2011 to 2015 with a 64% increase from 2012 to 2013. The clear increase in demand for PICCs in our institution is directly linked to the advent of outpatient intravenous antibiotic services. In this paper, we assess the impact that the use of PICCs combined with intravenous outpatient treatment may have on cost and hospital bed demand. We advocate that a more widespread implementation of this service throughout Ireland may result in significant cost savings as well as decreasing the number of patients on hospital trollies.

  9. Experience with the bonanno catheter in the management of OHSS from IVF-ET Cycles.

    Science.gov (United States)

    Okohue, J E; Oriji, V K; Ikimalo, J I

    2017-07-01

    To document our experience with the use of the Bonanno catheter as a closed abdominal drain for OHSS Methods: A retrospective study of all IVF embryo transfer (ET) treatment cycles carried out between May 2006 and April 2009 at a dedicated IVF centre. Case notes of patients with OHSS were retrieved and the outcome of the continuous closed abdominal drain with Bonanno catheter documented. Within the period under review, 234 patients had controlled ovarian stimulation with ultrasound guided egg retrieval. Two hundred and twenty eight (228) got to the stage of embryo transfer with 72 clinical pregnancies. The clinical pregnancy rate was 31.58%. Fourteen (6%) of those who were stimulated developed OHSS and had a closed abdominal drain of the ascitic fluid using the Bonanno catheter. The average number of days of the abdominal drainage was 7.5days and the average volume of ascitic fluid drained from a patient per day was 2454.9 + 748mls. Eight (8) patients who had OHSS achieved clinical pregnancy (six intrauterine, one ectopic and one heterotopic pregnancies), giving a clinical pregnancy rate of 57.14% in patients with OHSS. Four patients had blocked Bonanno catheters and three of them had the catheter changed while the fourth had the catheter successfully flushed. Four patients had the insertion site dressing changed due to soaking with ascitic fluid. There was no incidence of injury to intra abdominal organs or broken catheter. Bonanno Catheter is both effective and safe in draining ascitic fluid following OHSS.

  10. Intraventricular catheter placement by electromagnetic navigation safely applied in a paediatric major head injury patient.

    Science.gov (United States)

    Aufdenblatten, Christoph Alexander; Altermatt, Stefan

    2008-09-01

    In the management of severe head injuries, the use of intraventricular catheters for intracranial pressure (ICP) monitoring and the option of cerebrospinal fluid drainage is gold standard. In children and adolescents, the insertion of a cannula in a compressed ventricle in case of elevated intracranial pressure is difficult; therefore, a pressure sensor is placed more often intraparenchymal as an alternative option. In cases of persistent elevated ICP despite maximal brain pressure management, the use of an intraventricular monitoring device with the possibility of cerebrospinal fluid drainage is favourable. We present the method of intracranial catheter placement by means of an electromagnetic navigation technique.

  11. Catheter-related infections in a northwestern São Paulo reference unit for burned patients care

    Directory of Open Access Journals (Sweden)

    Cláudio Penido Campos Júnior

    Full Text Available Despite improvements in care and rehabilitation of burned patients, infections still remain the main complication and death cause. Catheter-related infections are among the four most common infections and are associated with skin damage and insertion site colonization. There are few studies evaluating this kind of infection worldwide in this special group of patients. Padre Albino Hospital Burn Care Unit (PAHBCU is the only reference center in the Northwestern São Paulo for treatment of burned patients. This paper presents the results of a retrospective study aiming at describing the epidemiological and clinical features of catheter-related infections at PAHBCU.

  12. Intensive Home Hemodialysis: An Eye at the Past Looking for the Hemodialysis of the Future.

    Science.gov (United States)

    Naso, Agostino; Scaparrotta, Giuseppe; Naso, Elena; Calò, Lorenzo A

    2015-09-01

    Multiple observational studies along with a limited number of randomized clinical trials suggest that intensive hemodialysis (IHD) not only improves outcomes for uremic patients undergoing chronic dialysis but does so with a more favorable cost/benefit ratio compared with conventional hemodialysis. As a result of this, there has been a rapid increase in the interest in home hemodialysis (HHD) as HHD represents the easiest means of implementing IHD. While HHD has generated increased interest given its association with better outcomes/reduced hospitalizations, there are very few randomized controlled trials comparing HHD with other hemodialysis methods. Reported HHD-associated increased survival benefits compared with in-center hemodialysis are from uncontrolled studies, which raise patient selection bias as underlying the differences found. Thus, while HHD draws increasing attention, studies that pay careful attention to the psychosocial, demographic, and clinical factors associated with patients selected to undergo HHD will be needed to ultimately demonstrate its benefits, clarify the clinical applications, and determine the limits of IHD use in dialysis patients. Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  13. Phlebitis associated with peripheral intravenous catheters in adults admitted to hospital in the Western Brazilian Amazon

    Directory of Open Access Journals (Sweden)

    Sandra Maria Sampaio Enes

    2016-04-01

    Full Text Available Abstract OBJECTIVE To identify the presence of phlebitis and the factors that influence the development of this complication in adult patients admitted to hospital in the western Brazilian Amazon. METHOD Exploratory study with a sample of 122 peripheral intravenous catheters inserted in 122 patients in a medical unit. Variables related to the patient and intravenous therapy were analyzed. For the analysis, we used chi-square tests of Pearson and Fisher exact test, with 5% significance level. RESULTS Complication was the main reason for catheter removal (67.2%, phlebitis was the most frequent complication (31.1%. The mean duration of intravenous therapy use was 8.81 days in continuous and intermittent infusion (61.5%, in 20G catheter (39.3%, inserted in the dorsal hand vein arc (36.9 %, with mean time of usage of 68.4 hours. The type of infusion (p=0.044 and the presence of chronic disease (p=0.005 and infection (p=0.007 affected the development of phlebitis. CONCLUSION There was a high frequency of phlebitis in the sample, being influenced by concomitant use of continuous and intermittent infusion of drugs and solutions, and more frequent in patients with chronic diseases and infection.

  14. Unplanned Start on Peritoneal Dialysis Right after PD Catheter Implantation for Older People with End-Stage Renal Disease.

    Science.gov (United States)

    Povlsen, Johan V; Sørensen, Anette Bagger; Ivarsen, Per

    2015-11-01

    Unplanned start on dialysis remains a major problem for the dialysis community worldwide. Late-referred patients with end-stage renal disease (ESRD) and urgent need for dialysis are overrepresented among older people. These patients are particularly likely to be started on in-center hemodialysis (HD), with a temporary vascular access known to be associated with excess mortality and increased risks of potentially lethal complications such as bacteremia and central venous thrombosis or stenosis.The present paper describes in detail our program for unplanned start on automated peritoneal dialysis (APD) right after PD catheter implantation and summarizes our experiences with the program so far. Compared with planned start on PD after at least 2 weeks of break-in between PD catheter implantation and initiation of dialysis, unplanned start may be associated with a slight increased risk of mechanical complications but apparently no detrimental effect on mortality, peritonitis-free survival, or PD technique survival.In our opinion and experience, the risk of serious complications associated with the implantation and immediate use of a PD catheter is less than the risk of complications associated with unplanned start on HD with a temporary central venous catheter (CVC). Unplanned start on APD is a gentle, safe, and feasible alternative to unplanned start on HD with a temporary CVC that is also valid for the late-referred older patient with ESRD and urgent need for dialysis. Copyright © 2015 International Society for Peritoneal Dialysis.

  15. Smoking has no impact on survival and it is not associated with ACE gene I/D polymorphism in hemodialysis patients.

    Science.gov (United States)

    Kiss, István; Kiss, Zoltán; Kerkovits, Lóránt; Paksy, András; Ambrus, Csaba

    2017-01-01

    The relationship between smoking and mortality in patients on hemodialysis is controversial. Earlier studies showed that the insertion/deletion (I/D) polymorphism of the ACE gene might have an effect on mortality. The aim of this study was to test the impact of smoking on survival and whether this association was influenced by ACE gene I/D polymorphism in patients on maintenance hemodialysis. In this prospective, multicenter cohort study we analyzed 709 prevalent patients on maintenance hemodialysis. Patients were allocated into groups based on their smoking habit. Outcome data were collected during the 144-month follow-up period. Outcomes of current smokers and lifelong non-smokers were compared. In order to control for interactions between predictor variables, we also identified 160 matched pairs for further sub-analysis. The vast majority of patients (67%) were non-smokers, followed by current smokers (22.2%) and ex-smokers (9.8%). Smoking had no impact on survival in the matched pair analysis ( p = 0.99). After adjustment for ACE I/D polymorphism and other co-variates, smoking had no effect on survival. Our data suggest that smoking has no impact on survival; neither is it associated with ACE gene I/D polymorphism in hemodialysis patients.

  16. Discrepancy between effects of carbapenems and flomoxef in treating nosocomial hemodialysis access-related bacteremia secondary to extended spectrum beta-lactamase producing Klebsiella pneumoniae in patients on maintenance hemodialysis.

    Science.gov (United States)

    Yang, Chih-Chao; Li, Shau-Hsuan; Chuang, Feng-Rong; Chen, Chih-Hung; Lee, Chih-Hsiung; Chen, Jin-Bor; Wu, Chien-Hsing; Lee, Chien-Te

    2012-09-05

    Hemodialysis (HD) patients are susceptible to extended spectrum beta-lactamase (ESBL)-producing bacterial infections. Because the optimal treatment and clinical significance of ESBL-producing Klebsiella pneumoniae (ESBL-Kp) HD access-related bacteremia remain unclear, we conducted this retrospective study to determine the clinical outcomes of patients treated with either flomoxef or a carbapenem. The eligibility criterion was fistula or graft- or catheter- related ESBL-Kp bacteremia in patients on maintenance HD. The clinical characteristics and antibiotic management were analyzed. Outcome was determined by mortality resulting from bacteremia during the 14-day period after the first positive blood culture for flomoxef-susceptible ESBL-Kp. The 57 patients studied were predominantly elderly, malnourished, with a history of severe illnesses and broad-spectrum antibiotic use before the onset of bacteremia, and with severe septicemia as determined by the Pitt bacteremia score (PBS). The study population comprised 7 fistula, 8 graft, and 42 HD catheter-related bacteremia (CRB) cases, and the mortality rate was high (36/57, 63.2%) in these 57 patients. Of 42 patients with CRB, those in the deceased group (27/42, 64.3%) had significantly lower levels of serum albumin, longer prior hospital stay and duration of catheter-dependent HD, and higher PBS than patients in the survived group. Failure to receive effective antibiotics (flomoxef or a carbapenem) within 5 days after onset of bacteremia and treatment with flomoxef both significantly contributed to higher mortality. Multivariate analyses revealed that flomoxef use, PBS, and catheter-dependent HD >30 days were independently associated with increased mortality (OR, 3.52; 95% CI, 1.19-58.17, OR, 2.92; 95% CI, 1.36-6.26 and OR, 5.73; 95% CI, 1.21-63.2, respectively). Considering the high mortality rate, ESBL-Kp should be recognized as a possible pathogen in patients on maintenance HD at high risk of acquiring HD access

  17. Discrepancy between effects of carbapenems and flomoxef in treating nosocomial hemodialysis access-related bacteremia secondary to extended spectrum beta-lactamase producing klebsiella pneumoniae in patients on maintenance hemodialysis

    Directory of Open Access Journals (Sweden)

    Yang Chih-Chao

    2012-09-01

    Full Text Available Abstract Background Hemodialysis (HD patients are susceptible to extended spectrum beta-lactamase (ESBL-producing bacterial infections. Because the optimal treatment and clinical significance of ESBL-producing Klebsiella pneumoniae (ESBL-Kp HD access-related bacteremia remain unclear, we conducted this retrospective study to determine the clinical outcomes of patients treated with either flomoxef or a carbapenem. Methods The eligibility criterion was fistula or graft- or catheter- related ESBL-Kp bacteremia in patients on maintenance HD. The clinical characteristics and antibiotic management were analyzed. Outcome was determined by mortality resulting from bacteremia during the 14‐day period after the first positive blood culture for flomoxef-susceptible ESBL-Kp. Results The 57 patients studied were predominantly elderly, malnourished, with a history of severe illnesses and broad-spectrum antibiotic use before the onset of bacteremia, and with severe septicemia as determined by the Pitt bacteremia score (PBS. The study population comprised 7 fistula, 8 graft, and 42 HD catheter-related bacteremia (CRB cases, and the mortality rate was high (36/57, 63.2% in these 57 patients. Of 42 patients with CRB, those in the deceased group (27/42, 64.3% had significantly lower levels of serum albumin, longer prior hospital stay and duration of catheter-dependent HD, and higher PBS than patients in the survived group. Failure to receive effective antibiotics (flomoxef or a carbapenem within 5 days after onset of bacteremia and treatment with flomoxef both significantly contributed to higher mortality. Multivariate analyses revealed that flomoxef use, PBS, and catheter-dependent HD >30 days were independently associated with increased mortality (OR, 3.52; 95% CI, 1.19–58.17, OR, 2.92; 95% CI, 1.36–6.26 and OR, 5.73; 95% CI, 1.21–63.2, respectively. Conclusions Considering the high mortality rate, ESBL-Kp should be recognized as a possible pathogen in

  18. Endovascular Revascularization of Chronically Thrombosed Arteriovenous Fistulas and Grafts for Hemodialysis: A Retrospective Study in 15 Patients With 18 Access Sites

    International Nuclear Information System (INIS)

    Weng Meijui; Chen, Matt Chiung-Yu; Chi Wenche; Liu Yichun; Liang, Huei-Lung; Pan, Huay-Ben

    2011-01-01

    The current study retrospectively evaluated whether endovascular revascularization of chronically thrombosed and long-discarded vascular access sites for hemodialysis was feasible. Technical and clinical success rates, postintervention primary and secondary patency rates, and complications were reported. During a 1-year period, we reviewed a total of 924 interventions performed for dysfunction and/or failed hemodialysis vascular access sites and permanent catheters in 881 patients. In patients whose vascular access-site problems were considered untreatable or were considered treatable with a high risk of failure and access-site abandonment, we attempted to revascularize (resurrect) the chronically occluded and long-discarded (mummy) vascular access sites. We attempted to resurrect a total of 18 mummy access sites (mean age 46.6 ± 38.7 months; range 5–144) in 15 patients (8 women and 7 men; mean age 66.2 ± 11.5 years; age range 50–85) and had an overall technical success rate of 77.8%. Resurrection failure occurred in 3 fistulas and in 1 straight graft. The clinical success rate was 100% at 2 months after resurrection. In the 14 resurrected vascular access sites, 6 balloon-assisted maturation procedures were required in 5 fistulas; after access-site maturation, a total of 22 interventions were performed to maintain access-site patency. The mean go-through time for successful resurrection procedures was 146.6 ± 34.3 min (range 74–193). Postmaturation primary patency rates were 71.4 ± 12.1% at 30 days, 57.1 ± 13.2% at 60 days, 28.6 ± 13.4% at 90 days, and 19 ± 11.8% at 180 days. Postmaturation secondary patency rates were 100% at 30, 60, and 90 days and 81.8 ± 11.6% at 180 days. There were 2 major complications consisting of massive venous ruptures in 2 mummy access sites during balloon dilation; in both cases, prolonged balloon inflation failed to achieve hemostasis, but percutaneous N-butyl cyanoacrylate glue seal-off was performed successfully

  19. Changes in Plasma Copeptin Levels during Hemodialysis : Are the Physiological Stimuli Active in Hemodialysis Patients?

    NARCIS (Netherlands)

    Ettema, Esmee M.; Kuipers, Johanna; Assa, Solmaz; Bakker, Stephan J. L.; Groen, Henk; Westerhuis, Ralf; Gaillard, Carlo A. J. M.; Gansevoort, Ron T.; Franssen, Casper F. M.

    2015-01-01

    Objectives Plasma levels of copeptin, a surrogate marker for the vasoconstrictor hormone arginine vasopressin (AVP), are increased in hemodialysis patients. Presently, it is unknown what drives copeptin levels in hemodialysis patients. We investigated whether the established physiological stimuli

  20. Combined ultrasound and fluoroscopy guided port catheter implantation-High success and low complication rate

    International Nuclear Information System (INIS)

    Gebauer, Bernhard; El-Sheik, Michael; Vogt, Michael; Wagner, Hans-Joachim

    2009-01-01

    Purpose: To evaluate peri-procedural, early and late complications as well as patients' acceptance of combined ultrasound and fluoroscopy guided radiological port catheter implantation. Materials and methods: In a retrospective analysis, all consecutive radiological port catheter implantations (n = 299) between August 2002 and December 2004 were analyzed. All implantations were performed in an angio suite under analgosedation and antibiotic prophylaxis. Port insertion was guided by ultrasonographic puncture of the jugular (n = 298) or subclavian (n = 1) vein and fluoroscopic guidance of catheter placement. All data of the port implantation had been prospectively entered into a database for interventional radiological procedures. To assess long-term results, patients, relatives or primary physicians were interviewed by telephone; additional data were generated from the hospital information system. Patients and/or the relatives were asked about their satisfaction with the port implantion procedure and long-term results. Results: The technical success rate was 99% (298/299). There were no major complications according to the grading system of SIR. A total of 23 (0.33 per 1000 catheter days) complications (early (n = 4), late (n = 19)) were recorded in the follow-period of a total of 72,727 indwelling catheter days. Infectious complications accounted for 0.15, thrombotic for 0.07 and migration for 0.04 complications per 1000 catheter days. Most complications were successfully treated by interventional measures. Twelve port catheters had to be explanted due to complications, mainly because of infection (n = 9). Patients' and relatives' satisfaction with the port catheter system was very high, even if complications occurred. Conclusion: Combined ultrasound and fluoroscopy guided port catheter implantation is a very safe and reliable procedure with low peri-procedural, early and late complication rate. The intervention achieves very high acceptance by the patients and

  1. Unusual Complication of Suprapubic Cystostomy in a Male Patient with Tetraplegia: Traction on Foley Catheter Leading to Extrusion of Foley Balloon from Urinary Bladder and Suprapubic Urinary Fistula – Importance of Securely Anchoring Suprapubic Catheter with Adhesive Tape or BioDerm Tube Holder

    Directory of Open Access Journals (Sweden)

    Subramanian Vaidyanathan

    2007-01-01

    Full Text Available Suprapubic cystostomy is recommended to patients with neuropathic bladder to prevent complications of long-term urethral catheter drainage. We present a 50-year-old male patient with tetraplegia who had long-term urethral catheter drainage. Following flexible cystoscopy, he developed a urine leak from the right side of the scrotum. Suprapubic cystostomy was performed. After suprapubic cystostomy, the urinary fistula healed completely. A follow-up cystourethrogram confirmed an intact urethra with no leak of contrast. Six weeks later, this patient presented with a hole below the suprapubic cystostomy through which a small amount of urine was leaking. A keyhole dressing had been applied around the suprapubic catheter and the catheter was hanging loosely, thus permitting traction on the catheter, especially when the urine bag was full. Computerised tomography of the pelvis showed extrusion of the Foley balloon from the urinary bladder, but the tip of the catheter was still located within the bladder. The extruded catheter was removed and a Foley catheter was inserted, ensuring that the balloon was inflated within the urinary bladder. The suprapubic catheter was secured firmly to the anterior abdominal wall with a BioDerm Tube Holder, thus preventing any traction on the catheter or Foley balloon. The urine leak through the hole below the suprapubic cystostomy stopped and the sinus healed. This case illustrates the need to anchor the suprapubic catheter securely to the anterior abdominal wall with adhesive tape or BioDerm Tube Holder to prevent traction and consequent displacement of the catheter or Foley balloon.

  2. CT guided transthoracic catheter drainage of intrapulmonary abscess.

    Science.gov (United States)

    Yunus, Mahira

    2009-10-01

    To determine the efficacy of CT- guided transthoracic catheter drainage of intrapulmonary abscess considering success rate versus complications. This prospective study was carried out at radiology department of Al-Noor Specialist Hospital, Makkah, Saudi Arabia, from 1.1.2003 to 31.12.2005. Nineteen patients were selected for CT guided percutaneous drainage. Under CT guidance catheter placement was carried out using Seldinger technique. Nineteen patients with lung abscess were selected for the percutaneous CT guided drainage. Eight (42.105%) patients encountered no complications and lung abscess completely resolved with no residual cavity. Five (26.31%) patients developed pneumothorax, which was the most common complication of this study. These patients were kept under observation and followed-up by chest X-rays. Three (15.78%) had mild pneumothorax, which resolved and needed no further management, while two (10.52%) patients developed moderate pneumothorax and chest tube was inserted. Two (10.52%) patients developed mild haemoptysis which resolved within two hours, hence, no further management was required. Two (10.52%) patients had residual cavity and surgery was performed. Congenital cystic adenomatoid malformation (CCAM) was found in both cases. Two patients out of nineteen patients (10.52%) developed bronchopleural fistula and were operated. No mortality occurred during or after the procedure. CT allows optimal placement of catheter and hence enables safe and effective percutaneous evacuation of lung abscess. The morbidity and mortality of patients with percutaneous catheter drainage is lower than with surgical resection. Hence, CT guided drainage should be considered the first therapeutic choice in most patients of lung abscess who do not respond to medical therapy.

  3. A Brief Recap of Tips and Surgical Manoeuvres to Enhance Optimal Outcome of Surgically Placed Peritoneal Dialysis Catheters

    Directory of Open Access Journals (Sweden)

    Jodie H. Frost

    2012-01-01

    Full Text Available Background. Peritoneal dialysis (PD is an effective option of renal replacement therapy for ESRF, offering advantages over haemodialysis. Peritoneal dialysis catheter (PDC placement is thought to be the key to successful PD and the economic advantages are lost if a patient switches to HD in the 1st year. This paper is a brief document elaborating a recap of published literature, looking at various surgical tips and manoeuvres to enhance optimal outcome of PDC placement. Methods. A search strategy assessing for access team, preoperative antibiotic prophylaxis, type of catheter, catheter exit site, intraoperative catheter trial, optimal time to commence PD, hernia repairs, number of cuffs, catheter-embedding procedures, rectus sheath tunnelling, laparoscopic fixing, omentopexy, omentectomy, the “Y”-Tec system, resection of epiploic appendages, adhesiolysis, a trained surgeon, and perioperative catheter care protocol was used looking at various databases. Findings. The complications of catheterrelated dysfunction can be reduced with advanced planning of access placement, immaculate surgery, and attention to catheter insertion techniques. Conclusion. The success of a peritoneal dialysis programme depends upon functional and durable long term access to the peritoneal cavity; this depends on placement techniques and competent surgeons and psychosocial support to the patient. The various technical tips and manoeuvres elaborated here should be considered options carried out to improve outcome and reduce catheter dysfunction.

  4. Indwelling catheter care

    Science.gov (United States)

    Foley catheter ... You will need to make sure your indwelling catheter is working properly. You will also need to ... not get an infection or skin irritation. Make catheter and skin care part of your daily routine. ...

  5. Comparison of the Effectiveness of a Virtual Simulator With a Plastic Arm Model in Teaching Intravenous Catheter Insertion Skills.

    Science.gov (United States)

    Günay İsmailoğlu, Elif; Zaybak, Ayten

    2018-02-01

    The objective of this study was to compare the effectiveness of a virtual intravenous simulator with a plastic arm model in teaching intravenous catheter insertion skills to nursing students. We used a randomized controlled quasi-experimental trial design and recruited 65 students who were assigned to the experimental (n = 33) and control (n = 32) groups using the simple random sampling method. The experimental group received intravenous catheterization skills training on the virtual intravenous simulator, and the control group received the same training on a plastic model of a human arm. Data were collected using the personal information form, intravenous catheterization knowledge assessment form, Intravenous Catheterization Skill Test, Self-Confidence and Satisfaction Scale, and Fear Symptoms Scale. In the study, the mean scores in the control group were 20.44 for psychomotor skills, 15.62 for clinical psychomotor skills, 31.78 for self-confidence, and 21.77 for satisfaction. The mean scores in the experimental group were 45.18 for psychomotor skills, 16.28 for clinical psychomotor skills, 34.18 for self-confidence, and 43.89 for satisfaction. The results indicated that psychomotor skills and satisfaction scores were higher in the experimental group, while the clinical psychomotor skills and self-confidence scores were similar in both groups. More students in the control group reported experiencing symptoms such as cold and sweaty hands, significant restlessness, and tense muscles than those in the experimental group.

  6. Thermistor guided radiofrequency ablation of atrial insertion sites in patients with accessory pathways.

    Science.gov (United States)

    Tracy, C M; Moore, H J; Solomon, A J; Rodak, D J; Fletcher, R D

    1995-11-01

    Radiofrequency ablation has gained acceptance in the treatment of patients with symptomatic Wolff-Parkinson-White syndrome. The purpose of this study was to characterize the relation between temperature and other electroconductive parameters in patients undergoing atrial insertion accessory pathway ablation utilizing a thermistor equipped catheter. The mean temperature and power at sites of atrial insertion ablation are lower than has been previously associated with creation of radiofrequency lesions in the ventricle. While high cavitary blood flow in the atrium may result in cooling, the thinner atrial tissue may require less energy to achieve adequate heating than ventricular myocardium.

  7. The Effect of the Type of Hemodialysis Buffer on the QTc Interval in Patients on Chronic Hemodialysis

    Directory of Open Access Journals (Sweden)

    Reza Hekmat

    2009-03-01

    Full Text Available Background: Identifying the sources of variation in QTc measurementsis important for preventing arrhythmias during and afterhemodialysis. The present study was designed to determine thecorrelation between the type of hemodialysis buffer and thechanges in QTc interval in patients on chronic hemodialysis.Methods: Fifty-nine patients on chronic hemodialysis whoreferred in winter 2007 to hemodialysis centers of Ghaem andHashemi Nejad hospitals, in Mashhad, Iran, were divided intotwo groups according to their last dialysate buffer: acetate orbicarbonate. Electrocardiography, arterial blood gas parameters,serum K+, Na+, ionized calcium, and albumin levels weremeasured prior to and after hemodialysis in all patients.Results: All arterial blood gas parameters and serum electrolytesconcentrations were increased except K+ levels that weresignificantly decreased with hemodialysis. PCO2 and QTc intervalswere slightly increased in all patients, however thisincrease was not statistically significant. We found that thetype of dialysate affected the QTc interval, HCO3, base excess,base excess of extra cellular fluid, and base bufferchanges with no effect on ionized calcium, pH, PCO2, andserum albumin concentration. QTc interval was prolonged byusing bicarbonate and shortened by using acetate dialysatebuffer. We found no correlation between the variations of QTcinterval and serum electrolytes or arterial blood gas parametersin either group.Conclusion: Bicarbonate buffer use in hemodialysis prolongedQTc interval and acetate buffer shortened it. This effectis independent of serum electrolytes and pH changes duringhemodialysis. The effect of bicarbonate buffer is probablydue to more tolerability of ultra filtration, more effectiveedema reduction and augmented body electro-conductivity.

  8. Frequent hemodialysis in children.

    Science.gov (United States)

    Warady, Bradley A; Fischbach, Michel; Geary, Denis; Goldstein, Stuart L

    2007-07-01

    Frequent hemodialysis is currently conducted in a limited number of pediatric dialysis centers. However, the preliminary experience with children who have undergone procedures such as "daily" intensive hemodiafiltration and nocturnal hemodialysis has been positive, with the allowance for unrestricted diets and fluid intake, the lack of need for phosphate binders, excellent metabolic and blood pressure control, and, in the case of hemodiafiltration, excellent growth. The provision of frequent daily hemodialysis with the NxStage System has also recently been introduced to pediatrics. An overview about what is currently understood regarding the technical and clinical application of these approaches to therapy for children with end-stage renal disease form the basis for this article and highlight the impact of the procedures to date and the need for additional experience and collaborative data collection.

  9. Extending the use of the pacing pulmonary artery catheter for safe minimally invasive cardiac surgery.

    Science.gov (United States)

    Levin, Ricardo; Leacche, Marzia; Petracek, Michael R; Deegan, Robert J; Eagle, Susan S; Thompson, Annemarie; Pretorius, Mias; Solenkova, Nataliya V; Umakanthan, Ramanan; Brewer, Zachary E; Byrne, John G

    2010-08-01

    In this study, the therapeutic use of pacing pulmonary artery catheters in association with minimally invasive cardiac surgery was evaluated. A retrospective study. A single institutional university hospital. Two hundred twenty-four consecutive patients undergoing minimally invasive cardiac surgery through a small (5-cm) right anterolateral thoracotomy using fibrillatory arrest without aortic cross-clamping. Two hundred eighteen patients underwent mitral valve surgery (97%) alone or in combination with other procedures. Six patients underwent other cardiac operations. In all patients, the pacing pulmonary artery catheter was used intraoperatively to induce ventricular fibrillation during the cooling period, and in the postoperative period it also was used in 37 (17%) patients who needed to be paced, mainly for bradyarrhythmias (51%). There were no complications related to the insertion of the catheters. Six (3%) patients experienced a loss of pacing capture, and 2 (1%) experienced another complication requiring the surgical removal of the catheter. Seven (3%) patients needed postoperative implantation of a permanent pacemaker. In combination with minimally invasive cardiac surgery, pacing pulmonary artery catheters were therapeutically useful to induce ventricular fibrillatory arrest intraoperatively and for obtaining pacing capability in the postoperative period. Their use was associated with a low number of complications. Copyright 2010 Elsevier Inc. All rights reserved.

  10. Arterial line pressure control enhanced extracorporeal blood flow prescription in hemodialysis patients

    Directory of Open Access Journals (Sweden)

    Rosales Laura

    2008-11-01

    Full Text Available Abstract Background In hemodialysis, extracorporeal blood flow (Qb recommendation is 300–500 mL/min. To achieve the best Qb, we based our prescription on dynamic arterial line pressure (DALP. Methods This prospective study included 72 patients with catheter Group 1 (G1, 1877 treatments and 35 arterio-venous (AV fistulae Group 2 (G2, 1868 treatments. The dialysis staff was trained to prescribe Qb sufficient to obtain DALP between -200 to -250 mmHg. We measured ionic clearance (IK: mL/min, access recirculation, DALP (mmHg and Qb (mL/min. Six prescription zones were identified: from an optimal A zone (Qb > 400, DALP -200 to -250 to zones with lower Qb E (Qb -199. Results Treatments distribution in A was 695 (37% in G1 vs. 704 (37.7% in G2 (P = 0.7. In B 150 (8% in G1 vs. 458 (24.5% in G2 (P P = 0.62. IK in A was 214 ± 34 (G1 vs. 213 ± 35 (G2 (P = 0.65. IK Anova between G2 zones was: A vs. C and D (P P = 0.02. Conclusion In conclusion, an optimal Qb can de prescribed with DALP of -200 mmHg. Staff adherence to DLAP treatment prescription could be reached up to 81.3% in catheters and 84.1% in AV fistulae.

  11. Effect of hemodialysis on leflunomide plasma concentrations.

    Science.gov (United States)

    Beaman, Jasmine M; Hackett, L Peter; Luxton, Grant; Illett, Kenneth F

    2002-01-01

    To report on the influence of hemodialysis on the disposition of leflunomide in a woman with end-stage renal disease. A 65-year-old white woman with a history of diabetes, end-stage renal disease, rheumatoid arthritis, vasculitis, and leg ulcers was admitted to the hospital with a flare in the symptoms of joint pain and vasculitis. Prior to admission, she had been treated for rheumatoid arthritis with methotrexate 7.5 mg once a week. Due to adverse effects from methotrexate and continuing painful joints, leflunomide was considered as a therapeutic alternative. A loading dose of 100 mg was followed two days later by a daily dose of 10 mg. The active metabolite of leflunomide (A771726) was measured before and after hemodialysis and between hemodialysis sessions over a period of 80 days. Pre- and post-hemodialysis concentrations were compared for 17 sessions during this time. Based on the initial measured concentrations, the leflunomide dose was increased to 20 mg/d for several weeks before being reduced to 15 mg due to elevated liver enzymes. Although renal pathways are responsible in part for excretion of A771726, the concentrations achieved in this patient at doses of 10-20 mg/d were at the low end of the range reported in the literature. It was shown that pre- and post-hemodialysis concentrations of A771726 did not differ significantly. Thus, the low concentrations of A771726 were not a result of the hemodialysis. Steady-state concentrations of A771726 in plasma were not affected by hemodialysis or renal impairment. Reduction of the dose of leflunomide in patients with chronic renal failure undergoing hemodialysis does not appear to be required.

  12. De-implementation strategy to Reduce the Inappropriate use of urinary and intravenous CATheters: study protocol for the RICAT-study.

    Science.gov (United States)

    Laan, Bart J; Spijkerman, Ingrid J B; Godfried, Mieke H; Pasmooij, Berend C; Maaskant, Jolanda M; Borgert, Marjon J; Opmeer, Brent C; Vos, Margreet C; Geerlings, Suzanne E

    2017-01-10

    Urinary and (peripheral and central) intravenous catheters are widely used in hospitalized patients. However, up to 56% of the catheters do not have an appropriate indication and some serious complications with the use of these catheters can occur. The main objective of our quality improvement project is to reduce the use of catheters without an appropriate indication by 25-50%, and to evaluate the affecting factors of our de-implementation strategy. In a multicenter, prospective interrupted time series analysis, several interventions to avoid inappropriate use of catheters will be conducted in seven hospitals in the Netherlands. Firstly, we will define a list of appropriate indications for urinary and (peripheral and central) intravenous catheters, which will restrict the use of catheters and urge catheter removal when the indication is no longer appropriate. Secondly, after the baseline measurements, the intervention will take place, which consists of a kick-off meeting, including a competitive feedback report of the baseline measurements, and education of healthcare workers and patients. Additional strategies based on the baseline data and local conditions are optional. The primary endpoint is the percentage of catheters with an inappropriate indication on the day of data collection before and after the de-implementation strategy. Secondary endpoints are catheter-related infections or other complications, catheter re-insertion rate, length of hospital (and ICU) stay and mortality. In addition, the cost-effectiveness of the de-implementation strategy will be calculated. This study aims to reduce the use of urinary and intravenous catheters with an inappropriate indication, and as a result reduce the catheter-related complications. If (cost-) effective it provides a tool for a nationwide approach to reduce catheter-related infections and other complications. Dutch trial registry: NTR6015 . Registered 9 August 2016.

  13. Bacillus Cereus catheter related bloodstream infection in a patient in a patient with acute lymphblastic leukemia

    Directory of Open Access Journals (Sweden)

    Lütfiye Öksüz

    2012-01-01

    Full Text Available Bacillus cereus infection is rarely associated with actual infection and for this reason single positive blood culture is usually regarded as contamination . However it may cause a number of infections, such catheter-related blood stream infections. Significant catheter-related bloodstream infections (CRBSI caused by Bacillus spp. are mainly due to B.cereus and have been predominantly reported in immunocompromised hosts1 . Catheter removal is generally advised for management of infection. In this report, catheter-related bacteremia caused by B.cereus in a patient with acute lymphoblastıc leukemia (ALL in Istanbul Medical Faculty was presented.A 44-year old man presented with fatigue, weight loss, epistaxis and high fever. A double-lumen Hickman–catheter (Bard 12.0 Fr, Round Dual Lumen was inserted by surgical cut-down to access the right subclavian vein which would be necessary for allogeneic stem cell transplantation. Three weeks later the patient presented with high fever and headache. Bacillus spp. was isolated from the cathether while blood culture obtained from the peripheral vein remained negative. The bacterial identification was confirmed as B.cereus using VITEK identification system It has been reported Bacillus cereus septicemia may be fatal in immunocompromised hosts despite broad-spectrum appropriate treatment10. Catheter removal is essential for prevention of recurrent bacteremia. Long-term cathater salvage should be reserved for appropriate patient group.

  14. Thyroid hormone concentrations in dialysate during hemodialysis in children

    International Nuclear Information System (INIS)

    Waters, W.; Bulla, M.; Buschsieweke, U.; Kutzim, H.; Koeln Univ.

    1981-01-01

    Thyroxine (T4) concentration in dialysate in the course of hemodialysis was determined in 15 children. Concentrations were measured by a modified radioimmunoassay. During hemodialysis there was a slight increase in T4 concentration. At the end of hemodialysis T4 concentration was about 50% higher than soon after the onset of hemodialysis. The loss of T4 into dialysate during hemodialysis was 19.2 μg; the loss of T3 was less than 75 ng. The amount of the daily loss of thyroid hormones into dialysate was found to be in the range of normal urinary excretion. The lowering of serum thyroid hormone concentrations in children on hemodialysis cannot be explained by the loss of these hormones into dialysate. (orig.) [de

  15. Liquid- and air-filled catheters without balloon as an alternative to the air-filled balloon catheter for measurement of esophageal pressure.

    Science.gov (United States)

    Beda, Alessandro; Güldner, Andreas; Carvalho, Alysson R; Zin, Walter Araujo; Carvalho, Nadja C; Huhle, Robert; Giannella-Neto, Antonio; Koch, Thea; de Abreu, Marcelo Gama

    2014-01-01

    Measuring esophageal pressure (Pes) using an air-filled balloon catheter (BC) is the common approach to estimate pleural pressure and related parameters. However, Pes is not routinely measured in mechanically ventilated patients, partly due to technical and practical limitations and difficulties. This study aimed at comparing the conventional BC with two alternative methods for Pes measurement, liquid-filled and air-filled catheters without balloon (LFC and AFC), during mechanical ventilation with and without spontaneous breathing activity. Seven female juvenile pigs (32-42 kg) were anesthetized, orotracheally intubated, and a bundle of an AFC, LFC, and BC was inserted in the esophagus. Controlled and assisted mechanical ventilation were applied with positive end-expiratory pressures of 5 and 15 cmH2O, and driving pressures of 10 and 20 cmH2O, in supine and lateral decubitus. Cardiogenic noise in BC tracings was much larger (up to 25% of total power of Pes signal) than in AFC and LFC (<3%). Lung and chest wall elastance, pressure-time product, inspiratory work of breathing, inspiratory change and end-expiratory value of transpulmonary pressure were estimated. The three catheters allowed detecting similar changes in these parameters between different ventilation settings. However, a non-negligible and significant bias between estimates from BC and those from AFC and LFC was observed in several instances. In anesthetized and mechanically ventilated pigs, the three catheters are equivalent when the aim is to detect changes in Pes and related parameters between different conditions, but possibly not when the absolute value of the estimated parameters is of paramount importance. Due to a better signal-to-noise ratio, and considering its practical advantages in terms of easier calibration and simpler acquisition setup, LFC may prove interesting for clinical use.

  16. Liquid- and air-filled catheters without balloon as an alternative to the air-filled balloon catheter for measurement of esophageal pressure.

    Directory of Open Access Journals (Sweden)

    Alessandro Beda

    Full Text Available BACKGROUND: Measuring esophageal pressure (Pes using an air-filled balloon catheter (BC is the common approach to estimate pleural pressure and related parameters. However, Pes is not routinely measured in mechanically ventilated patients, partly due to technical and practical limitations and difficulties. This study aimed at comparing the conventional BC with two alternative methods for Pes measurement, liquid-filled and air-filled catheters without balloon (LFC and AFC, during mechanical ventilation with and without spontaneous breathing activity. Seven female juvenile pigs (32-42 kg were anesthetized, orotracheally intubated, and a bundle of an AFC, LFC, and BC was inserted in the esophagus. Controlled and assisted mechanical ventilation were applied with positive end-expiratory pressures of 5 and 15 cmH2O, and driving pressures of 10 and 20 cmH2O, in supine and lateral decubitus. MAIN RESULTS: Cardiogenic noise in BC tracings was much larger (up to 25% of total power of Pes signal than in AFC and LFC (<3%. Lung and chest wall elastance, pressure-time product, inspiratory work of breathing, inspiratory change and end-expiratory value of transpulmonary pressure were estimated. The three catheters allowed detecting similar changes in these parameters between different ventilation settings. However, a non-negligible and significant bias between estimates from BC and those from AFC and LFC was observed in several instances. CONCLUSIONS: In anesthetized and mechanically ventilated pigs, the three catheters are equivalent when the aim is to detect changes in Pes and related parameters between different conditions, but possibly not when the absolute value of the estimated parameters is of paramount importance. Due to a better signal-to-noise ratio, and considering its practical advantages in terms of easier calibration and simpler acquisition setup, LFC may prove interesting for clinical use.

  17. Catheter visualisation in MR tomography: first animal experimental experiences with field inhomogeneity catheters

    International Nuclear Information System (INIS)

    Adam, G.; Glowinski, A.; Neuerburg, J.; Buecker, A.; Vaals, J.J. van; Hurtak, W.; Guenther, R.W.

    1997-01-01

    Purpose: To assess the feasibility of a new developed field inhomogeneity catheter for interventional MR imaging in vivo. Materials and methods: Three different prototypes of a field inhomogeneity catheter were investigated in 6 pigs. The catheters were introduced in Seldinger technique via the femoral vessels over a guide wire on an interventional MR system (Philips Gyroscan NT combined with a C-arm fluoroscopy unit [Philips BV 212[). Catheters were placed in veins and arteries. The catheter position was controlled by a fast gradient echo sequence (Turbo Field Echo [TEF[). Results: Catheters were introduced over a guide wire without complications in all cases. Using the field inhomogeneity concept, catheters were easily visualised in the inferior vena cava and the aorta by the fast gradient echo technique on MR in all cases. Although aortic branches were successfully cannulated, the catheters were not displayed by the TFE technique due to the complex and tortuous anatomy. All animals survived the experiments without complications. Conclusion: MR guided visualisation of a field inhomogeneity catheter is a simple concept which can be realised on each MR scanner and may allow intravascular MR guided interventions in future. (orig.) [de

  18. Catheter Angiography

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Catheter Angiography Catheter angiography ...

  19. [The Carboclip, a new, atraumatic vascular access for hemodialysis].

    Science.gov (United States)

    Bonnaud, P; Jehenne, G; Man, N K

    1994-01-01

    The Carboclip is a no-needle vascular access device made of an inverted Titanium body. The horizontal bar of 6 mm inner diameter is connected with artery and vein via a vascular graft. The vertical body houses an elastic plug in which is inserted a double canula diving in the blood stream for extracorporeal blood circulation (EBC). The body is wrapped by a flange made of microporous biocarbon in which the subcutaneous fibroblast will growth, forming an antimicrobial barrier and fixing the port to the skin. We report our experience on 30 devices implanted in 30 sheep with 26 extracorporeal circulation simulating hemodialysis. The results demonstrate good tightness of the plug as well at rest as during EBC procedure, sufficient blood flow rate of about 400 ml/min, and benefits of the microporous carbon flange.

  20. Catheter Angiography

    Medline Plus

    Full Text Available ... it will make the rest of the procedure pain-free. You will not feel the catheter in ... nurse if you notice any bleeding, swelling or pain at the site where the catheter entered the ...

  1. Catheter Angiography

    Medline Plus

    Full Text Available ... should inform the nurse if you notice any bleeding, swelling or pain at the site where the ... Rarely, the catheter punctures the artery, causing internal bleeding. It also is possible that the catheter tip ...

  2. Catheter Angiography

    Medline Plus

    Full Text Available ... or other procedures such as chemoembolization or selective internal radiation therapy. identify dissection or splitting in the ... days. Rarely, the catheter punctures the artery, causing internal bleeding. It also is possible that the catheter ...

  3. Catheter Angiography

    Medline Plus

    Full Text Available ... is performed using: x-rays with catheters computed tomography (CT) magnetic resonance imaging (MRI) In catheter angiography, ... tumor; this is called superselective angiography. Unlike computed tomography (CT) or magnetic resonance (MR) angiography , use of ...

  4. Catheter Angiography

    Medline Plus

    Full Text Available ... Catheter angiography uses a catheter, x-ray imaging guidance and an injection of contrast material to examine ... removable dental appliances, eye glasses and any metal objects or clothing that might interfere with the x- ...

  5. Catheter Angiography

    Medline Plus

    Full Text Available ... most cases, the kidneys will regain their normal function within five to seven days. Rarely, the catheter ... limitations of Catheter Angiography? Patients with impaired kidney function, especially those who also have diabetes, are not ...

  6. Multicenter study in monitoring central venous catheters complications in hematologic patiennts

    Directory of Open Access Journals (Sweden)

    Carmen García Gabás

    2013-05-01

    Full Text Available Most hematological patients suffer a significant venous damage related to different administrated intravenous therapy, being necessary to place central venous catheters (CVC. CVC is associated with various complications. The most common catheter-related complications are occlusion and infection. To avoid such of them, the development of protocols for insertion and care are needed, as well as recording and following up complications. To this end, we propose a cross-sectional carried out during 13 months whose main goal is to know the incidence of CVC- related complications (mainly occlusion and infection in hematological patients.Population included all the =14 ages patients admitted to different hematological units at Ramon y Cajal and Gregorio Marañón hospitals in Madrid and who signed informed consent. Socio-demographic, clinical characteristics and complications were entered into a log which included a pursuit of care protocol.

  7. Catheter Angiography

    Medline Plus

    Full Text Available ... lies. The catheter used in angiography is a long plastic tube about as thick as a strand of spaghetti. top of page How does the procedure work? Catheter angiography works much the same as a ...

  8. Catheter Angiography

    Medline Plus

    Full Text Available ... is performed using: x-rays with catheters computed tomography (CT) magnetic resonance imaging (MRI) In catheter angiography, a ... tumor; this is called superselective angiography. Unlike computed tomography (CT) or magnetic resonance (MR) angiography , use of a ...

  9. A central venous catheter coated with benzalkonium chloride for the prevention of catheter-related microbial colonization.

    Science.gov (United States)

    Moss, H A; Tebbs, S E; Faroqui, M H; Herbst, T; Isaac, J L; Brown, J; Elliott, T S

    2000-11-01

    In an attempt to overcome infections associated with central venous catheters, a new antiseptic central venous catheter coated with benzalkonium chloride on the internal and external surfaces has been developed and evaluated in a clinical trial. Patients (235) randomly received either a triple-lumen central venous catheter coated with benzalkonium chloride (117) or a polyurethane non-antiseptic catheter (118). The incidence of microbial colonization of both catheters and retained antiseptic activity of the benzalkonium chloride device following removal were determined. The benzalkonium chloride resulted in a significant reduction of the incidence of microbial colonization on both the internal and external catheter surfaces. The reduction in colonization was detected at both the intradermal (21 benzalkonium chloride catheters vs. 38 controls, P = 0.0016) and distal segments of the antiseptic-coated catheters. Following catheter removal retained activity was demonstrated in benzalkonium chloride catheters which had been in place for up to 12 days. No patients developed adverse reactions to the benzalkonium chloride catheters. The findings demonstrate that the benzalkonium chloride catheter significantly reduced the incidence of catheter-associated colonization.

  10. Reduction of Urinary Tract Infections Caused By Urethral Catheter through the Implementation of Hydrophobic Coating and Geometrical Modifications

    Science.gov (United States)

    Gare, Aya

    2013-11-01

    Catheter-Associated Urinary Tract Infection (CAUTI) is the most common nosocomial infection in the U.S. healthcare system. The obstruction of urine caused by confined air bubbles result in the development of urinary back-flow and stagnation, wherein microbial pathogens could multiply rapidly and colonization within catheters become commonplace. Infections can be prevented by aseptic insertion and the maintenance of a closed drainage system, keeping high infection control standards, and preventing back-flow from the catheter bag. The goal of this study is to assess the effectiveness of a simple, low cost, modification that may be implemented into current catheter designs to reduce the incidence of CAUTI. Using the principle of transmission of fluid-pressure and the Young-Laplace equation for capillary pressure difference, this research focuses on improving the liquid flow in the presence of confined bubbles to prevent stagnation and reflux of bacteria-ridden urine into the body. Preliminary experiments are performed on a variety of tubes with hydrophobic-coating the interior, as well as geometrically modifying the tubes. Proof-of-Concept Prototype tubes are used to represent the drainage system of the catheter structure.

  11. Effect of Isometric Hand Grip Exercises on Blood Flow and Placement of IV Catheters for Administration of Chemotherapy.

    Science.gov (United States)

    Ozkaraman, Ayse; Yesilbalkan, Öznur Usta

    2016-04-01

    Complications may occur in the subcutaneous or subdermal tissues during IV administration of chemotherapy related to blood flow and catheter placement. Daily isometric hand grip exercises were evaluated for their effect on blood flow in the vessels of the nondominant arm before placement of IV catheters and the success rate of IV catheter placement on the first attempt. The study focused on patients with non-Hodgkin lymphoma receiving the first and second cycles of chemotherapy. The intervention group performed daily isometric hand grip exercises before chemotherapy with peripheral catheter insertion. The control group performed routine activities only. Blood flow was measured by ultrasound in the brachial artery (BA) and brachial vein (BV) of the nondominant arm before the first (T1) and second (T2) cycles of chemotherapy. Blood flow slightly increased in the intervention group at T2 compared to T1. In the control group, blood flow decreased in the BA and did not change in the BV at T2 compared to T1. The success rate for first-attempt placement of a peripheral IV catheter was the same for the intervention and control groups.

  12. [Successful Awake Nasal Endotracheal Intubation with the McGrath Videolaryngoscope and a Soft-tipped Extra Firm Exchange Catheter in a Patient with a Necrotic Mandible].

    Science.gov (United States)

    Komasawa, Nobuyasu; Matsunami, Sayuri; Nakao, Kenta; Minami, Toshiaki

    2015-03-01

    Here we report a case of successful awake nasal intubation with the McGrath videolaryngscope (McGrath) in conjunction with a soft-tipped extra firm exchange catheter in a patient with a necrotic mandible developing a hole. An 81-year-old woman underwent partial tongue resection and cervical lymph node dissection. After additional radiation therapy, she developed a necrotic mandible with a hole from the oral cavity to the neck region. She was scheduled for resection of the necrotic mandible under general anesthesia. Upon sedation with dexmedetomidine 1.0 μg xkg-(1 )-xhr-(1 )and applying topical anesthesia with lido-aine, we inserted the McGrath orally and the soft- ipped extra firm tube exchange catheter (TE) nasally. Under the guide of the McGrath's monitor, we inserted the TE, using Magill forceps, into her trachea. A 6.0 mm internal diameter spiral tracheal tube was inserted via the TE uneventfully.

  13. Peripherally inserted central catheter - insertion

    Science.gov (United States)

    ... to Advanced Skills . 9th ed. New York, NY: Pearson; 2016:chap 29. Review Date 11/20/2017 ... Bethesda, MD 20894 U.S. Department of Health and Human Services National Institutes of Health Page last updated: ...

  14. Predisposing factors to phlebitis in patients with peripheral intravenous catheters: a descriptive study.

    Science.gov (United States)

    Uslusoy, Esin; Mete, Samiye

    2008-04-01

    The purpose of this study was to investigate the predisposing factors in the development of phlebitis in peripheral intravenous (IV) catheterization sites in patients treated with a variety of IV infusion solutions and drugs. Systematic observation of 568 IV sites inserted for fluid infusion and drug administration in 355 patients in the Department of General Surgery of a University Hospital in Turkey. A data collection tool was based on standards established by the Infusion Nurses Society. Patients' infusion sites were monitored every 24 h during treatment and for 48 h after discontinuation of the IV. In contrast to the usual findings in the literature, the authors found that infusion through an infusion pump and insertion of catheters in the veins around the elbow increased the risk of phlebitis. Also, the number of times infusions were started led to an increased rate of phlebitis. However, conflicting results were obtained about the relation between phlebitis, gender, and catheter size. Phlebitis causes sepsis, pain, additional diagnostic investigations, and treatments, and may lead to increased duration of hospitalization, patient's stress level, and financial burden, as well as increasing staff workload. Advanced practice nurses need to be aware of the factors that increase the likelihood of phlebitis and take appropriate measures to prevent it.

  15. Clinical usefulness of catheter-drawn blood samples and catheter tip cultures for the diagnosis of catheter-related bloodstream infections in neonatology: A systematic review.

    Science.gov (United States)

    Ferreira, Janita; Camargos, Paulo Augusto Moreira; Clemente, Wanessa Trindade; Romanelli, Roberta Maia de Castro

    2018-01-01

    Neonatal sepsis is the most frequent health care-associated infection in neonatal units. This study aimed to analyze articles on the clinical usefulness of catheter-drawn blood samples and catheter tip cultures for the diagnosis of intravascular catheter-related bloodstream infection (CRBSI) in neonates. A systematic search was performed for studies published from 1987-2017, without language restriction. Observational studies carried out in neonates with CRBSI diagnosed using catheter-drawn blood samples or catheter tip cultures were included. A total of 412 articles were identified in the databases and 10 articles were included. The 7 studies that evaluated central venous catheter tip cultures and cultures of catheter fragments presented sensitivities ranging from 58.5%-100% and specificities ranging from 60%-95.7%. Three studies that evaluated catheter-drawn blood cultures, paired with peripheral blood cultures, reported sensitivity and specificity of 94% and 71% when evaluated for the differential time to positivity. When quantitative evaluation was performed, the sensitivity and specificity were 80% and 99.4%. Most of the studies analyzed cultures from the central venous catheter tip and catheter fragments for the diagnosis of CRBSI in neonatal populations. The results of this review suggest that the analysis of the catheter-drawn blood samples and catheter tip cultures, paired with peripheral blood cultures, are efficient methods for the diagnosis of CRBSI in neonates. Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  16. Increased Cerebral Water Content in Hemodialysis Patients

    OpenAIRE

    Reetz, Kathrin; Abbas, Zaheer; Eitner, Frank; Gross, Theresa; Schulz, Jörg Bernhard; Floege, Jürgen; Shah, N. J.; Costa, Ana Sofia; Gras, Vincent; Tiffin-Richards, Frances; Mirzazade, Shahram; Holschbach, Bernhard; Frank, Rolf Dario; Vassiliadou, Athina; Krüger, Thilo

    2015-01-01

    Little information is available on the impact of hemodialysis on cerebral water homeostasis and its distribution in chronic kidney disease. We used a neuropsychological test battery, structural magnetic resonance imaging (MRI) and a novel technique for quantitative measurement of localized water content using 3T MRI to investigate ten hemodialysis patients (HD) on a dialysis-free day and after hemodialysis (2.4±2.2 hours), and a matched healthy control group with the same time interval. Neuro...

  17. Bacillus Cereus catheter related bloodstream infection in a patient in a patient with acute lymphblastic leukemia

    Directory of Open Access Journals (Sweden)

    Lütfiye Öksüz

    2012-01-01

    Full Text Available

    Bacillus cereus infection is rarely associated with actual infection and for this reason single positive blood culture is usually regarded as contamination . However it may cause a number of infections, such catheter-related blood stream infections. Significant catheter-related bloodstream infections (CRBSI caused by Bacillus spp. are mainly due to B.cereus and have been predominantly reported in immunocompromised hosts1 . Catheter removal is generally advised for management of infection. In this report, catheter-related bacteremia caused by B.cereus in a patient with acute lymphoblastıc leukemia (ALL in Istanbul Medical Faculty was presented.A 44-year old man presented with fatigue, weight loss, epistaxis and high fever. A double-lumen Hickman–catheter (Bard 12.0 Fr, Round Dual Lumen was inserted by surgical cut-down to access the right subclavian vein which would be necessary for allogeneic stem cell transplantation. Three weeks later the patient presented with high fever and headache. Bacillus spp. was isolated from the cathether while blood culture obtained from the peripheral vein remained negative. The bacterial identification was confirmed as B.cereus using VITEK identification system

    It has been reported Bacillus cereus septicemia may be fatal in immunocompromised hosts despite broad-spectrum appropriate treatment10. Catheter removal is essential for prevention of recurrent bacteremia. Long-term cathater salvage should be reserved for appropriate patient group.

  18. Catheter Angiography

    Medline Plus

    Full Text Available ... is injected through the catheter and reaches the blood vessels being studied, several sets of x-rays are taken. Then the catheter is removed and the incision site is closed by applying pressure on the area for approximately 10 to 20 ...

  19. Use of hemodialysis in meprobamate overdosage.

    Science.gov (United States)

    Lobo, P I; Spyker, D; Surratt, P; Westervelt, F B

    1977-02-01

    A case of meprobamate overdosage successfully treated with hemodialysis is described. The patient was admitted 4 hours after an overdosage of meprobamate (30-40 g) deeply unconscious, hypotensive, in respiratory failure and with a serum meprobamate level of 50 mg/100 ml. Hemodialysis was instituted using a Gambro parallel flow dialyzer and a portable re-circulating dialyzate delivery system (Redy, CCi Life Systems). Meprobamate removal with hemodialysis was 672+/-167 mg/hr with a corresponding clearance of 61.97+/-9.9 ml/min. Drug removal with forced diuresis was 177+/-23.4 mg/hr. Metabolic degradation of the drug was approximately 482 mg/hr with a plasma disappearance rate of 5.2%/hr. No drug could be detected in the dialyzate fluid after its passage through the Redy re-circulating dialyzate system. Because of the rapidity of metabolic degradation of meprobamate, we feel that hemodialysis should be reserved for severe clinical intoxication and either compromised normal excretory routes or progressive clinical deterioration.

  20. Severe Hemorrhage from Cervical Cancer Managed with Foley Catheter Balloon Tamponade

    Directory of Open Access Journals (Sweden)

    Tomohiro Sonoo

    2015-10-01

    Full Text Available A 67-year-old woman complaining of continuous fresh vaginal hemorrhage came to our emergency department in a pre-shock state. Examinations revealed an irregularly shaped mass in the uterus and active arterial bleeding. Emergent hysterectomy and interventional radiology were not immediately available. Foley catheter with 20mL water was inserted into the uterine cavity, then the balloon was pulled to obstruct the uterus output (Figure. Her vital signs became stabilized, and she was transferred to another hospital two days later.

  1. Peripheral Insertion of a Central Venous Access Device Under Fluoroscopic Guidance Using a Peripherally Accessed System (PAS) Port in the Forearm

    International Nuclear Information System (INIS)

    Hata, Yasuhiro; Morita, Sojiro; Morita, Yoshitaka; Awatani, Toshihide; Takasaki, Motohiro; Horimi, Tadashi; Ozawa, Zen

    1998-01-01

    Purpose: We describe the technique, efficacy, and complications of fluoroscopy-guided implantation of a central venous access device using a peripherally accessed system (PAS) port via the forearm. Methods: Beginning in July 1994, 105 central venous access devices were implanted in 104 patients for the long-term infusion of antibiotics or antineoplasmic agents, blood products, or parenteral nutrition. The devices was inserted under fluoroscopic guidance with real-time venography from a peripheral route. Results: All ports were successfully implanted. There were no procedure-related complications. No thrombosis or local infection was observed; however, in six patients catheter-related phlebitis occurred. Conclusion: Fluoroscopy-guided implantation of a central venous access device using a PAS port via the forearm is safe and efficacious, and injection of contrast medium through a peripheral IV catheter before introduction of the catheter helps to avoid catheter-related phlebitis

  2. 21 CFR 876.5665 - Water purification system for hemodialysis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Water purification system for hemodialysis. 876... SERVICES (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Therapeutic Devices § 876.5665 Water purification system for hemodialysis. (a) Identification. A water purification system for hemodialysis is a...

  3. Serum trypsin inhibitory capacity in hemodialysis patients

    International Nuclear Information System (INIS)

    Hashemi, Mohammad; Mehrabifar, Hamid; Homayooni, Fatemeh; Naderi, Mohammad; Montazerifar, Farzaneh; Ghavami, Saeid

    2009-01-01

    It has been established that overproduction of reactive oxygen species (ROS) occurs during hemodialysis causing oxidation of proteins. Alpha-1-antitrypsin is the major circulating anti-protease which contains methionine in the active site. The aim of the present study was to measure the level of serum trypsin inhibitory capacity (sTIC) in hemodialysis patients. This case-control study was performed in 52 hemodialysis patients and 49 healthy controls. sTIC was measured by enzymatic assay. The sTIC was significantly (P< 0.001) lower in hemodialysis patients (1.87 + - 0.67 micron mol/min/mL) than healthy controls (2.83 + - 0.44 micron mol/min/L). Reduction of sTIC may be due to the oxidation of methionine residue in the reactive site of alpha-1 antitrypsin. (author)

  4. A National Implementation Project to Prevent Catheter-Associated Urinary Tract Infection in Nursing Home Residents.

    Science.gov (United States)

    Mody, Lona; Greene, M Todd; Meddings, Jennifer; Krein, Sarah L; McNamara, Sara E; Trautner, Barbara W; Ratz, David; Stone, Nimalie D; Min, Lillian; Schweon, Steven J; Rolle, Andrew J; Olmsted, Russell N; Burwen, Dale R; Battles, James; Edson, Barbara; Saint, Sanjay

    2017-08-01

    Catheter-associated urinary tract infection (UTI) in nursing home residents is a common cause of sepsis, hospital admission, and antimicrobial use leading to colonization with multidrug-resistant organisms. To develop, implement, and evaluate an intervention to reduce catheter-associated UTI. A large-scale prospective implementation project was conducted in community-based nursing homes participating in the Agency for Healthcare Research and Quality Safety Program for Long-Term Care. Nursing homes across 48 states, Washington DC, and Puerto Rico participated. Implementation of the project was conducted between March 1, 2014, and August 31, 2016. The project was implemented over 12-month cohorts and included a technical bundle: catheter removal, aseptic insertion, using regular assessments, training for catheter care, and incontinence care planning, as well as a socioadaptive bundle emphasizing leadership, resident and family engagement, and effective communication. Urinary catheter use and catheter-associated UTI rates using National Healthcare Safety Network definitions were collected. Facility-level urine culture order rates were also obtained. Random-effects negative binomial regression models were used to examine changes in catheter-associated UTI, catheter utilization, and urine cultures and adjusted for covariates including ownership, bed size, provision of subacute care, 5-star rating, presence of an infection control committee, and an infection preventionist. In 4 cohorts over 30 months, 568 community-based nursing homes were recruited; 404 met inclusion criteria for analysis. The unadjusted catheter-associated UTI rates decreased from 6.78 to 2.63 infections per 1000 catheter-days. With use of the regression model and adjustment for facility characteristics, the rates decreased from 6.42 to 3.33 (incidence rate ratio [IRR], 0.46; 95% CI, 0.36-0.58; P project. Catheter utilization remained unchanged (4.50 at baseline, 4.45 at conclusion of project; IRR, 0

  5. Fast, automatic, and accurate catheter reconstruction in HDR brachytherapy using an electromagnetic 3D tracking system

    Energy Technology Data Exchange (ETDEWEB)

    Poulin, Eric; Racine, Emmanuel; Beaulieu, Luc, E-mail: Luc.Beaulieu@phy.ulaval.ca [Département de physique, de génie physique et d’optique et Centre de recherche sur le cancer de l’Université Laval, Université Laval, Québec, Québec G1V 0A6, Canada and Département de radio-oncologie et Axe Oncologie du Centre de recherche du CHU de Québec, CHU de Québec, 11 Côte du Palais, Québec, Québec G1R 2J6 (Canada); Binnekamp, Dirk [Integrated Clinical Solutions and Marketing, Philips Healthcare, Veenpluis 4-6, Best 5680 DA (Netherlands)

    2015-03-15

    Purpose: In high dose rate brachytherapy (HDR-B), current catheter reconstruction protocols are relatively slow and error prone. The purpose of this technical note is to evaluate the accuracy and the robustness of an electromagnetic (EM) tracking system for automated and real-time catheter reconstruction. Methods: For this preclinical study, a total of ten catheters were inserted in gelatin phantoms with different trajectories. Catheters were reconstructed using a 18G biopsy needle, used as an EM stylet and equipped with a miniaturized sensor, and the second generation Aurora{sup ®} Planar Field Generator from Northern Digital Inc. The Aurora EM system provides position and orientation value with precisions of 0.7 mm and 0.2°, respectively. Phantoms were also scanned using a μCT (GE Healthcare) and Philips Big Bore clinical computed tomography (CT) system with a spatial resolution of 89 μm and 2 mm, respectively. Reconstructions using the EM stylet were compared to μCT and CT. To assess the robustness of the EM reconstruction, five catheters were reconstructed twice and compared. Results: Reconstruction time for one catheter was 10 s, leading to a total reconstruction time inferior to 3 min for a typical 17-catheter implant. When compared to the μCT, the mean EM tip identification error was 0.69 ± 0.29 mm while the CT error was 1.08 ± 0.67 mm. The mean 3D distance error was found to be 0.66 ± 0.33 mm and 1.08 ± 0.72 mm for the EM and CT, respectively. EM 3D catheter trajectories were found to be more accurate. A maximum difference of less than 0.6 mm was found between successive EM reconstructions. Conclusions: The EM reconstruction was found to be more accurate and precise than the conventional methods used for catheter reconstruction in HDR-B. This approach can be applied to any type of catheters and applicators.

  6. Fast, automatic, and accurate catheter reconstruction in HDR brachytherapy using an electromagnetic 3D tracking system

    International Nuclear Information System (INIS)

    Poulin, Eric; Racine, Emmanuel; Beaulieu, Luc; Binnekamp, Dirk

    2015-01-01

    Purpose: In high dose rate brachytherapy (HDR-B), current catheter reconstruction protocols are relatively slow and error prone. The purpose of this technical note is to evaluate the accuracy and the robustness of an electromagnetic (EM) tracking system for automated and real-time catheter reconstruction. Methods: For this preclinical study, a total of ten catheters were inserted in gelatin phantoms with different trajectories. Catheters were reconstructed using a 18G biopsy needle, used as an EM stylet and equipped with a miniaturized sensor, and the second generation Aurora ® Planar Field Generator from Northern Digital Inc. The Aurora EM system provides position and orientation value with precisions of 0.7 mm and 0.2°, respectively. Phantoms were also scanned using a μCT (GE Healthcare) and Philips Big Bore clinical computed tomography (CT) system with a spatial resolution of 89 μm and 2 mm, respectively. Reconstructions using the EM stylet were compared to μCT and CT. To assess the robustness of the EM reconstruction, five catheters were reconstructed twice and compared. Results: Reconstruction time for one catheter was 10 s, leading to a total reconstruction time inferior to 3 min for a typical 17-catheter implant. When compared to the μCT, the mean EM tip identification error was 0.69 ± 0.29 mm while the CT error was 1.08 ± 0.67 mm. The mean 3D distance error was found to be 0.66 ± 0.33 mm and 1.08 ± 0.72 mm for the EM and CT, respectively. EM 3D catheter trajectories were found to be more accurate. A maximum difference of less than 0.6 mm was found between successive EM reconstructions. Conclusions: The EM reconstruction was found to be more accurate and precise than the conventional methods used for catheter reconstruction in HDR-B. This approach can be applied to any type of catheters and applicators

  7. Successful retrieval of an entrapped Rotablator burr using 5 Fr guiding catheter.

    Science.gov (United States)

    Kimura, Masayoshi; Shiraishi, Jun; Kohno, Yoshio

    2011-10-01

    Although burr entrapment is a rare complication of the Rotablator, it is extremely difficult to retrieve a fixedly entrapped burr without surgical procedure. An 84-year-old male with effort angina had heavily calcified coronary trees as well as severe stenosis in the mid LCx, and moderate stenosis in the proximal LCx, and in the LMT. We planned to perform rotational atherectomy in the LCx lesions. Using 7 Fr Q-curve guiding catheter and Rotawire floppy, we began to ablate using 1.5-mm burr at 200,000 rpm. Because the burr could not pass the proximal stenosis, we exchanged the wire for Rotawire extrasupport and the burr for 1.25-mm burr, and restarted the ablation at 220,000 rpm. Although the burr could manage to pass the proximal stenosis, it had become trapped in the mid LCx lesion. Simple pull on the Rotablator, rotation of the burr, and crossing the Conquest (Confianza) wire could not retrieve it. Thus, we cut off the drive shaft and sheath of the Rotablator, inserted 5 Fr 120-cm straight guiding catheter (Heartrail ST01; Terumo) through the remaining Rotablator system, pushed the catheter tip to the lesion around the burr as well as simultaneously pulled the Rotablator, and finally could retrieve it. Then we implanted stents in the LCx and in the LMT without difficulty. The 5 Fr straight guiding catheter might be useful for retrieving an entrapped burr (1.25-mm burr). Copyright © 2011 Wiley-Liss, Inc.

  8. Catheter versus non-catheter angiography in isolated third nerve palsy

    International Nuclear Information System (INIS)

    Lee, A.G.

    2007-01-01

    To discuss the controversies surrounding the indications for catheter angiography versus non-catheter and less invasive angiography techniques (e.g. magnetic resonance angiography (MRA) and computerized tomography angiography (CTA)) in the evaluation of patients with a third nerve palsy. Clinical opinion-perspective and literature review. The patient with an isolated third nerve palsy might have a vasculopathic (and typically benign, self limited course) etiology or a life threatening intracranial posterior communicating artery aneurysm. Although it is clear that non-isolated third nerve palsies require imaging directed at the topographical localization of the clinical findings, the evaluation of the neurologically isolated third nerve palsy remains controversial. The completeness of the external (i.e. somatic) motor dysfunction and the presence or absence of internal (i.e. pupillary) dysfunction are generally used to guide the choice of initial neuroimaging. Advances in MRA and CTA technology have reduced but not eliminated our dependence upon catheter angiography in this setting. A properly performed and interpreted MRA or CTA probably will be able to detect greater than 95 % of aneurysms producing a third nerve palsy. The issues surrounding the use of catheter angiography in third nerve palsy are reviewed. If the clinician is highly confident in the capability, availability, and reliability of the neuroradiologist and of their institutional experience and quality of less invasive non-catheter MRA and CTA and if the risk of aneurysm is low or if the risk of angiography is high (e.g. elderly, renal failure, iodinated contrast allergy, risk of stroke) then MRI and MRA (or CTA) may be a reasonable alternative to catheter angiography. Patients with a moderate or uncertain risk of aneurysm and a lower risk for catheter angiography or if there is a low confidence in the quality or the interpretation of the institutional MRA (or CTA) may still require catheter

  9. Phlebitis risk varies by peripheral venous catheter site and increases after 96 hours: a large multi-centre prospective study.

    Science.gov (United States)

    Cicolini, Giancarlo; Manzoli, Lamberto; Simonetti, Valentina; Flacco, Maria Elena; Comparcini, Dania; Capasso, Lorenzo; Di Baldassarre, Angela; Eltaji Elfarouki, Ghaleb

    2014-11-01

    This multi-centre prospective field study evaluated whether peripheral venous catheter site of insertion influences the risk of catheter-related phlebitis. Potential predictors of phlebitis were also investigated. Millions of patients worldwide use peripheral venous catheters, which frequently cause local complications including phlebitis, infection and obstruction. Although phlebitis predictors have been broadly investigated, uncertainties remain on the potential effect of cannulation anatomical site, duration and the appropriate time for catheter removal. A prospective cohort design was carried out from January-June 2012. The clinical course of each patient who received a new peripheral venous catheter for any cause in five Italian hospitals was followed by trained nurses until catheter removal. The presence of phlebitis was assessed every 24 hours using the Visual Infusion Phlebitis score. Analyses were based upon multilevel mixed-effects regression. The final sample consisted of 1498 patients. The average time for catheters in situ was 65·6 hours and 23·6% of the catheters were in place beyond 96 hours. Overall phlebitis incidence was 15·4%, 94·4% of which were grade 1. The likelihood of phlebitis independently increased with increasing catheter duration, being highest after 96 hours. Compared with patients with catheter placed in the dorsum of the hand (22·8% of the sample), those with the catheter located in the antecubital fossa (34·1%) or forearm were less likely to have a phlebitis of any grade. Antecubital fossa and forearm veins may be preferential sites for peripheral venous cannulation. Our results support Centers for Disease Control and Prevention recommendations to replace catheters in adults no later than 96 hours. A relevant proportion of healthcare personnel did not adhere to such guidelines - more attention to this issue is required. © 2014 John Wiley & Sons Ltd.

  10. Percutaneous catheter drainage of thoracic fluid: the usefulness and safety of bedside trocar placement under ultrasound guidance

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Heon [Seoul Medical Center, Seoul (Korea, Republic of)

    2006-07-15

    The author wanted to evaluate the usefulness and safety of the trocar technique for US-guided bedside catheter placement into thoracic fluid collections, and this technique has generally been reserved for the larger or superficial fluid collections. 42 drainage procedures were performed in 38 patients at the bedside. The patients were positioned supine or semi-upright. A drainage catheter system with a stylet and cannula assembly was used and all of the catheters were inserted using the trocar technique. The procedures consisted of drainage of empyema (n=14), malignant effusion (n=13), lung abscess (n=3), massive transudate (n=8), hemothorax (n=2) and chest wall hematoma (n=2). The clinical results were classified as successful (complete and partially successful), failure or undetermined. The medical records and images were retrospectively reviewed to evaluate the success rate, the complications and the procedure time. Technical success was achieved in all of the 42 procedures. With using the trocar technique, all the catheters were placed into even the small collections without significant complications. Drainage was successful in 36 (85.7%) of the 42 procedures. The average volume of thoracic fluid that was aspirated manually at the time of catheter placement was 420 mL (range: 35 to 1470 mL). The procedure time was less than 10 minutes from US-localization to complete catheter placement in all of the procedures. The trocar technique under US guidance can be an efficient and safe alternative to the Seldinger or guide-wire exchange technique for bedside catheter placement in the critically ill or hemodynamically unstable patients.

  11. A system to use electromagnetic tracking for the quality assurance of brachytherapy catheter digitization

    Energy Technology Data Exchange (ETDEWEB)

    Damato, Antonio L., E-mail: adamato@lroc.harvard.edu; Viswanathan, Akila N.; Don, Sarah M.; Hansen, Jorgen L.; Cormack, Robert A. [Department of Radiation Oncology, Dana-Farber Cancer Institute/Brigham and Women’s Hospital, Boston, Massachusetts 02115 (United States)

    2014-10-15

    Purpose: To investigate the use of a system using electromagnetic tracking (EMT), post-processing and an error-detection algorithm for detecting errors and resolving uncertainties in high-dose-rate brachytherapy catheter digitization for treatment planning. Methods: EMT was used to localize 15 catheters inserted into a phantom using a stepwise acquisition technique. Five distinct acquisition experiments were performed. Noise associated with the acquisition was calculated. The dwell location configuration was extracted from the EMT data. A CT scan of the phantom was performed, and five distinct catheter digitization sessions were performed. No a priori registration of the CT scan coordinate system with the EMT coordinate system was performed. CT-based digitization was automatically extracted from the brachytherapy plan DICOM files (CT), and rigid registration was performed between EMT and CT dwell positions. EMT registration error was characterized in terms of the mean and maximum distance between corresponding EMT and CT dwell positions per catheter. An algorithm for error detection and identification was presented. Three types of errors were systematically simulated: swap of two catheter numbers, partial swap of catheter number identification for parts of the catheters (mix), and catheter-tip shift. Error-detection sensitivity (number of simulated scenarios correctly identified as containing an error/number of simulated scenarios containing an error) and specificity (number of scenarios correctly identified as not containing errors/number of correct scenarios) were calculated. Catheter identification sensitivity (number of catheters correctly identified as erroneous across all scenarios/number of erroneous catheters across all scenarios) and specificity (number of catheters correctly identified as correct across all scenarios/number of correct catheters across all scenarios) were calculated. The mean detected and identified shift was calculated. Results: The

  12. A system to use electromagnetic tracking for the quality assurance of brachytherapy catheter digitization

    International Nuclear Information System (INIS)

    Damato, Antonio L.; Viswanathan, Akila N.; Don, Sarah M.; Hansen, Jorgen L.; Cormack, Robert A.

    2014-01-01

    Purpose: To investigate the use of a system using electromagnetic tracking (EMT), post-processing and an error-detection algorithm for detecting errors and resolving uncertainties in high-dose-rate brachytherapy catheter digitization for treatment planning. Methods: EMT was used to localize 15 catheters inserted into a phantom using a stepwise acquisition technique. Five distinct acquisition experiments were performed. Noise associated with the acquisition was calculated. The dwell location configuration was extracted from the EMT data. A CT scan of the phantom was performed, and five distinct catheter digitization sessions were performed. No a priori registration of the CT scan coordinate system with the EMT coordinate system was performed. CT-based digitization was automatically extracted from the brachytherapy plan DICOM files (CT), and rigid registration was performed between EMT and CT dwell positions. EMT registration error was characterized in terms of the mean and maximum distance between corresponding EMT and CT dwell positions per catheter. An algorithm for error detection and identification was presented. Three types of errors were systematically simulated: swap of two catheter numbers, partial swap of catheter number identification for parts of the catheters (mix), and catheter-tip shift. Error-detection sensitivity (number of simulated scenarios correctly identified as containing an error/number of simulated scenarios containing an error) and specificity (number of scenarios correctly identified as not containing errors/number of correct scenarios) were calculated. Catheter identification sensitivity (number of catheters correctly identified as erroneous across all scenarios/number of erroneous catheters across all scenarios) and specificity (number of catheters correctly identified as correct across all scenarios/number of correct catheters across all scenarios) were calculated. The mean detected and identified shift was calculated. Results: The

  13. Executive summary: Diagnosis and Treatment of Catheter-Related Bloodstream Infection: Clinical Guidelines of the Spanish Society of Clinical Microbiology and Infectious Diseases (SEIMC) and the Spanish Society of Intensive Care Medicine and Coronary Units (SEMICYUC).

    Science.gov (United States)

    Chaves, Fernando; Garnacho-Montero, José; Del Pozo, José Luis; Bouza, Emilio; Capdevila, José Antonio; de Cueto, Marina; Domínguez, M Ángeles; Esteban, Jaime; Fernández-Hidalgo, Nuria; Fernández Sampedro, Marta; Fortún, Jesús; Guembe, María; Lorente, Leonardo; Paño, Jose Ramón; Ramírez, Paula; Salavert, Miguel; Sánchez, Miguel; Vallés, Jordi

    2018-02-01

    Catheter-related bloodstream infections (CRBSI) constitute an important cause of hospital-acquired infection associated with morbidity, mortality, and cost. The aim of these guidelines is to provide updated recommendations for the diagnosis and management of CRBSI in adults. Prevention of CRBSI is excluded. Experts in the field were designated by the two participating Societies (Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica and the Sociedad Española de Medicina Intensiva, Crítica y Unidades Coronarias). Short-term peripheral venous catheters, non-tunneled and long-term central venous catheters, tunneled catheters and hemodialysis catheters are covered by these guidelines. The panel identified 39 key topics that were formulated in accordance with the PICO format. The strength of the recommendations and quality of the evidence were graded in accordance with ESCMID guidelines. Recommendations are made for the diagnosis of CRBSI with and without catheter removal and of tunnel infection. The document establishes the clinical situations in which a conservative diagnosis of CRBSI (diagnosis without catheter removal) is feasible. Recommendations are also made regarding empirical therapy, pathogen-specific treatment (coagulase-negative staphylococci, Sthaphylococcus aureus, Enterococcus spp, Gram-negative bacilli, and Candida spp), antibiotic lock therapy, diagnosis and management of suppurative thrombophlebitis and local complications. Copyright © 2017 Elsevier España, S.L.U. and Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica. All rights reserved.

  14. Declotting a Thrombosed Brescia-Cimino Fistula by Manual Catheter-Directed Aspiration of the Thrombus

    International Nuclear Information System (INIS)

    Turmel-Rodrigues, Luc A

    2005-01-01

    Acute thrombosis of native fistulae for hemodialysis occurs more rarely than for prosthetic grafts. The vascular access should be reopened as soon as possible in order to resume regular dialysis and to avoid resorting to a temporary central line. Manual aspiration is one of the numerous methods described in this setting. Clinical examination is essential to rule out local infection, which is the only serious contraindication to percutaneous maneuvers. Two introducer-sheaths are placed in a criss-cross fashion in order to gain access to the venous outflow and to the anastomosis. Access to the venous outflow is performed first in order to check the proximal extent of the thrombosis. Heparin and antibiotics are injected systemically. A similar maneuver is then performed in the direction of the anastomosis. The aspiration phase is then initiated. A 7-9 Fr aspiration catheter is pushed through the 'venous' introducer. Manual aspiration is created through a 50 ml syringe while the catheter is progressively removed with back and forth movements. The catheter and the contents of the syringe are flushed through a gauze on the working table to evaluate the amount of thrombus which has been removed and the maneuver is repeated as often as necessary to remove all the thrombus. Once all the clots located downstream from the venous introducer have been removed, any unmasked underlying stenosis is NOT dilated at this stage since it provides protection against major embolism coming from the inflow. The aspiration catheter is then pushed through the 'arterial' introducer down to the anastomosis in order to aspirate the thrombus located between the tip of the introducer and the anastomosis. Dilatation of unmasked stenoses is finally performed using high-pressure balloons. The holes made by the two introducers are closed using a U-shaped suture with interposition of a short piece of plastic and the patient is sent back to the nephrologists for dialysis

  15. Silicone Foley′s catheter: A useful splint in ear surgeries

    Directory of Open Access Journals (Sweden)

    Karanth Siddharth

    2008-01-01

    Full Text Available Maintenance of ear projection and post auricular sulcus in staged ear reconstruction in microtia is a trying problem. So also is the maintenance of the patency of the external auditory meatus following recanalization and meatoplasty. Numerous splints and dressing techniques have been described for the above situations. Some of the problems encountered include the availability of the materials, cost, expertise in fabrication and compliance. Aims: To devise a simple, reliable, inexpensive and readily available splint for the maintenance of post auricular sulcus and external auditory meatus opening. Settings and Design: A silicone catheter is made out of a soft and inert material that doesn′t cause tissue necrosis or any loss of skin graft. The basic design is that of a simple, self-retaining type of splint that doesn′t dislodge and can be prepared within minutes on the operating table. Materials and Methods: This splint has been used in four cases of microtia reconstruction and one case of congenital external auditory meatus stenosis between June 2006 and August 2007. A 14 or 16 Fr silicone Foley′s catheter was used. The proximal end of a catheter of required length was retained and the distal part was cut off. The catheter was looped into a circle around the base of the reconstructed ear and secured in position with a suture. A similar construct was used in cases of external auditory meatus reconstruction or recanalization. The funnel-shaped distal drainage end was sutured to the circular frame near the region of the tragus. This funnel was inserted into the external auditory canal. Results: The catheter was found to sit snugly in the newly created sulcus, thereby maintaining the sulcus and ear projection. It aided in maintaining the meatal opening of a satisfactory diameter in the case of external auditory canal recanalization. It was never found to slip or get dislodged in any of the cases. There was no skin graft loss or tissue necrosis

  16. Bronchial lumen is the safer route for an airway exchange catheter in double-lumen tube replacement: preventable complication in airway management for thoracic surgery.

    Science.gov (United States)

    Wu, Hsiang-Ling; Tai, Ying-Hsuan; Wei, Ling-Fang; Cheng, Hung-Wei; Ho, Chiu-Ming

    2017-10-01

    There is no current consensus on which lumen an airway exchange catheter (AEC) should be passed through in double-lumen endotracheal tube (DLT) to exchange for a single-lumen endotracheal tube (SLT) after thoracic surgery. We report an unusual case to provide possible solution on this issue. A 71-year-old man with lung adenocarcinoma had an event of a broken exchange catheter used during a DLT replacement with a SLT, after a video-assisted thoracic surgery. The exchange catheter was impinged at the distal tracheal lumen and snapped during manipulation. All three segments of the catheter were retrieved without further airway compromises. Placement of airway tube exchanger into the tracheal lumen of double-lumen tube is a potential contributing factor of the unusual complication. We suggest an exchange catheter be inserted into the bronchial lumen in optimal depth with the adjunct of video laryngoscope, as the safe method for double-lumen tube exchange.

  17. The efficacy of Jackson drain in the application to be a tunnel pleural catheter (TPC) in the management of malignant pleural effusion.

    Science.gov (United States)

    Tscheikuna, Jamsak; Thomrongpairoj, Preecha; Disayabutr, Suppareurg

    2011-06-01

    Malignant pleural effusion (MPE) is a common clinical problem in patients with advanced cancer and portends a poor prognosis, which means survival of less than six months. In June 1997, the US-FDA approved an indwelling TPC with a one-way drainage valve to be used in the management of MPE. Although popularity of this TPC has increased over the past few years, the experience with this device remains limited in Thai patients. One of the reasons is its high cost. Assess the efficacy and the safety of customary indwelling TPC by using Jackson drain in the management of patients with symptomatic MPE. Ten patients with symptomatic MPE were receiving these catheters (18 Fr Silicone catheters with 25 cm fenestrated length) to drain effusion via plastic vacuum bottles (250 ml) every other day or as needed to relieve dyspnea. The patient's dyspnic respiration, quality of life, and comfort during the catheter's application were quantified with a Borg score, the St. George Respiratory Disease Questionnaire (SGRQ), and the comfort's score, respectively. These parameters were recorded at initial (before insertion) and 2-week follow-up visit. Pain after 24 hours of each insertion was quantified by visual pain analogue scale (VPAS). Patients were followed until either death or catheter removal. The Borg score, SGRQ, and comfort's score showed significant improvement at 2-week visit (p drain was effective in the treatment of MPE as a TPC without early complications.

  18. Severe Valproic Acid Intoxication Responding to Hemodialysis

    Directory of Open Access Journals (Sweden)

    Ali Ertuğ Arslanköylü

    2017-08-01

    Full Text Available Valproic acid is a commonly used antiepileptic drug which causes intoxication easily due to its narrow therapeutic window. Here, we present a child with valproic acid poisoning who responded to hemodialysis. A 14-year-old male patient with epilepsy and mental motor retardation was admitted to the pediatric intensive care unit due to valproic acid intoxication. Plasma valproic acid level was 710 µg/mL. The patient’s vital signs were stable and a decrease was observed in the valproic acid and ammonia levels with supportive treatment at the beginning. On the third day of the admission, hemodynamic and mental status of the patient deteriorated, plasma ammonia and lactate levels elevated, thus, we decided to perform hemodialysis. After hemodialysis, the patient’s hemodynamic status and mental function improved in conjunction with the reduction in valproic acid, ammonia and lactate levels. Thus he was transferred to the pediatric ward. Hemodialysis may be considered an effective treatment choice for severe valproic acid intoxication. Here, it was shown that hemodialysis may also be effective in patients with deteriorated general status under supportive treatment in the late phase of valproic acid intoxication.

  19. The safety and feasibility of guidezilla catheter in complex coronary interventions and an observational study.

    Science.gov (United States)

    Ma, Jianying; Hou, Lei; Qian, Juying; Ge, Lei; Zhang, Feng; Chang, Shufu; Xu, Rende; Qin, Qing; Ge, Junbo

    2017-10-01

    The monorail Guidezilla guide extension catheter was designed to provide additional backup and facilitate device delivery in percutaneous coronary intervention (PCI) for complex coronary anatomy such as chronic total occlusion (CTO), extreme vessel tortuosity, diseased bypass grafts, and anomalous coronary arteries, among others.The present retrospective, single-center study included 188 consecutive patients who underwent PCI using the Guidezilla catheter from March 2015 to August 2016. Study outcomes were rates of target lesion crossing success, procedural success, and complications.The Guidezilla catheter was used most commonly in PCI of CTOs (45%) and heavy proximal calcification (37%), followed by tortuosity (10%), previously deployed proximal stents (4%), and coronary artery anomaly (4%). The right coronary artery (48%) was most commonly intervened followed by the left ascending (35%) and left circumflex (17%) arteries. Rates of target lesion crossing success and procedural success were both 99%, with one device-related periprocedural complication, namely proximal vessel dissection secondary to deep insertion which was successfully treated with stent implantation. Ninety percent of PCI were performed and completed successfully by radial access.In a single center with experienced operators, the use of the Guidezilla guide extension catheter in PCI of complex coronary anatomy performed mostly via radial artery access appeared safe and efficacious, and greatly facilitated device delivery.

  20. Proteomic Investigations into Hemodialysis Therapy

    Directory of Open Access Journals (Sweden)

    Mario Bonomini

    2015-12-01

    Full Text Available The retention of a number of solutes that may cause adverse biochemical/biological effects, called uremic toxins, characterizes uremic syndrome. Uremia therapy is based on renal replacement therapy, hemodialysis being the most commonly used modality. The membrane contained in the hemodialyzer represents the ultimate determinant of the success and quality of hemodialysis therapy. Membrane’s performance can be evaluated in terms of removal efficiency for unwanted solutes and excess fluid, and minimization of negative interactions between the membrane material and blood components that define the membrane’s bio(incompatibility. Given the high concentration of plasma proteins and the complexity of structural functional relationships of this class of molecules, the performance of a membrane is highly influenced by its interaction with the plasma protein repertoire. Proteomic investigations have been increasingly applied to describe the protein uremic milieu, to compare the blood purification efficiency of different dialyzer membranes or different extracorporeal techniques, and to evaluate the adsorption of plasma proteins onto hemodialysis membranes. In this article, we aim to highlight investigations in the hemodialysis setting making use of recent developments in proteomic technologies. Examples are presented of why proteomics may be helpful to nephrology and may possibly affect future directions in renal research.

  1. Proteomic Investigations into Hemodialysis Therapy

    Science.gov (United States)

    Bonomini, Mario; Sirolli, Vittorio; Pieroni, Luisa; Felaco, Paolo; Amoroso, Luigi; Urbani, Andrea

    2015-01-01

    The retention of a number of solutes that may cause adverse biochemical/biological effects, called uremic toxins, characterizes uremic syndrome. Uremia therapy is based on renal replacement therapy, hemodialysis being the most commonly used modality. The membrane contained in the hemodialyzer represents the ultimate determinant of the success and quality of hemodialysis therapy. Membrane’s performance can be evaluated in terms of removal efficiency for unwanted solutes and excess fluid, and minimization of negative interactions between the membrane material and blood components that define the membrane’s bio(in)compatibility. Given the high concentration of plasma proteins and the complexity of structural functional relationships of this class of molecules, the performance of a membrane is highly influenced by its interaction with the plasma protein repertoire. Proteomic investigations have been increasingly applied to describe the protein uremic milieu, to compare the blood purification efficiency of different dialyzer membranes or different extracorporeal techniques, and to evaluate the adsorption of plasma proteins onto hemodialysis membranes. In this article, we aim to highlight investigations in the hemodialysis setting making use of recent developments in proteomic technologies. Examples are presented of why proteomics may be helpful to nephrology and may possibly affect future directions in renal research. PMID:26690416

  2. Concurrent use of pigtail and loop snare catheters for percutaneous retrieval of dislodged central venous port catheter

    Directory of Open Access Journals (Sweden)

    Ming-Tsung Chuang

    2011-11-01

    Full Text Available The purpose of this study was to report our experience of percutaneous retrieval of dislodged port catheters with concurrent use of pigtail and loop snare catheters. During a 5-year period at our institute (June 2005 to July 2010, a total of 23 dislodged port catheters were retrieved. The interval between port catheter implantation and dislodged catheter retrieval ranged from 43 days to 1,414 days (mean 586.7 days. The time of delayed retrieval ranged from 1 day to 45 days (mean 4.6 days. All dislodged catheters were retrieved with the concurrent use of pigtail and loop snare catheters via femoral venous route. The prevalence of port catheter dislodgement at our institute was 3.4%. All dislodged port catheters were removed successfully with pigtail and loop snare catheters together. No procedure-related complications were encountered, except for transient arrhythmia in two patients, which required no medication. In conclusion, the concurrent use of pigtail and loop snare catheters is a feasible and easy way for percutaneous retrieval of a dislodged central venous port catheter.

  3. Metal stents insertion in the treatment of the patients with benign oesophageal strictures

    International Nuclear Information System (INIS)

    Valek, V.; Benda, K.; Hrobar, P.; Mrazova, J.; Prasek, J.; Vomela, J.; Muenzova, H.; Hep, A.; Stefl, M.

    1996-01-01

    Between October 1993 and June 1995 the authors inserted in the Department of Radiology in University Hospital Bohunice in 16 of their patients with benign stenosis of the oesophagus an expandable metals stent. the aetiology of the stenosis was long-term reflux oesophagitis (6x), postoperative benign stenosis in anastomosis (3x), corrosive structure (2x), epidermolysis bulosa oesophagi (2x) and post-radiation structure (1x). In two patients the aetiology of the stenosis was unknown. All the patients suffered at the the of the stent insertion from marked dysphagia (stage 3 and/or 4). The indication for oesophageal stent implantation was always carefully considered by an interdisciplinary indication committee. Before the stent insertion all the stenoses have been repeatedly unsuccessfully dilated with balloon dilatation catheter. In total, 25 stents were used. In seven patients were inserted more as one stent. The intervention itself was preceded by a double contrast X-ray examination of oesophagus, oesophagoscopy with biopsy to verify the stricture aetiology, computed tomography and endosonography. No complications associated with the intervention have been encountered and stent insertions have always been well tolerated. (authors). 1 tab., 3 figs., 9 refs

  4. Innovative Approaches to Neuraxial Blockade in Children: The Introduction of Epidural Nerve Root Stimulation and Ultrasound Guidance for Epidural Catheter Placement

    Directory of Open Access Journals (Sweden)

    Ban CH Tsui

    2006-01-01

    Full Text Available Continuous epidural blockade remains the cornerstone of pediatric regional anesthesia. However, the risk of catastrophic trauma to the spinal cord when inserting direct thoracic and high lumbar epidural needles in anesthetized or heavily sedated pediatric patients is a concern. To reduce this risk, research has focused on low lumbar or caudal blocks (ie, avoiding the spinal cord and threading catheters from distal puncture sites in a cephalad direction. However, with conventional epidural techniques, including loss-of-resistance for localization of the needle, optimal catheter tip placement is difficult to assess because considerable distances are required during threading. Novel approaches include electrical epidural stimulation for physiological confirmation and segmental localization of epidural catheters, and ultrasound guidance for assessing related neuroanatomy and real-time observation of the needle puncture and, potentially, catheter advancement. The present article provides a brief and focused review of these two advances, and outlines recent clinical experiences relevant to pediatric epidural anesthesia.

  5. A Simple Radiological Technique for Demonstration of Incorrect Positioning of a Foley Catheter with Balloon Inflated in the Urethra of a Male Spinal Cord Injury Patient

    Directory of Open Access Journals (Sweden)

    Subramanian Vaidyanathan

    2006-01-01

    Full Text Available In a male patient with cervical spinal cord injury, the urinary bladder may go into spasm when a urethral catheter is removed and a new Foley catheter is inserted. Before the balloon is inflated, the spastic bladder may push the Foley catheter out or the catheter may slip out of a small-capacity bladder. An inexperienced health professional may inflate the balloon of a Foley catheter in the urethra without realizing that the balloon segment of the catheter is lying in the urethra instead of the urinary bladder. When a Foley balloon is inflated in the urethra, a tetraplegic patient is likely to develop autonomic dysreflexia. This is a medical emergency and requires urgent treatment. Before the incorrectly placed Foley catheter is removed, it is important to document whether the balloon has been inflated in the urinary bladder or not. The clinician should first use the always available tools of observation and palpation at the bedside without delays of transportation. A misplaced balloon will often be evident by a long catheter sign, indicating excessive catheter remaining outside the patient. Radiological diagnosis is not frequently required and, when needed, should employ the technique most readily available, which might be a body and pelvic CT without intravenous contrast. An alternative radiological technique to demonstrate the position of the balloon of the Foley catheter is described. Three milliliters of nonionic X-ray contrast medium, Ioversol (OPTIRAY 300, is injected through the side channel of the Foley catheter, which is used for inflating the balloon. Then, with a catheter-tip syringe, 30 ml of sterile Ioversol is injected through the main lumen of the Foley catheter. Immediately thereafter, an X-ray of the pelvis (including perineum is taken. By this technique, both the urinary bladder and balloon of the Foley catheter are visualized by the X-ray contrast medium. When a Foley catheter has been inserted correctly, the balloon of the

  6. Progression of scoliosis in patients with spastic quadriplegia after the insertion of an intrathecal baclofen pump.

    Science.gov (United States)

    Ginsburg, Glen M; Lauder, Anthony J

    2007-11-15

    Medical and radiographic review of 19 consecutive patients with spastic quadriplegia before and after intrathecal baclofen pump insertion with special attention paid to progression of scoliosis. Many orthopedic surgeons who treat spastic quadriplegic patients have noticed a trend of marked scoliosis progression after the administration of intrathecal baclofen (ITB) via subcutaneous pump and catheter. The purpose of this study is to quantify scoliosis progression in this patient population before and after baclofen administration and compare this to published natural history data. The authors had noted rapid progression of scoliosis in spastic quadriplegic patients after intrathecal baclofen pump insertion. This had been noted at other centers, but no significant statistical analysis had been done comparing prepump to postpump scoliosis progression in these patients. To document the magnitude and rate of scoliosis progressions after the placement of an ITB pump, the charts and radiographs of 19 consecutive nonambulatory patients with spastic quadriplegia and an ITB pump were reviewed. To document the rate of scoliosis progression, each patient had at least 2 pre and 2 postpump insertion spinal radiographs made. All radiographs were made with the patients in the supine position without orthoses. A board-certified orthopedic surgeon reviewed these radiographs. Skeletal maturity was assessed using Risser grading. Catheter tip location and rate of baclofen administration were recorded. For 19 patients with complete radiographic data, average Cobb angles were 10.2 degrees before pump insertion and 25 degrees at an average of 20.9 months after pump insertion (P quadriplegia and ITB pump. The authors are now performing spinal fusions for curves that exceed 40 degrees to 50 degrees in the presence of an ITB pump as recommended by previous reviews of scoliosis and accompanying quadriplegia.

  7. WE-A-17A-03: Catheter Digitization in High-Dose-Rate Brachytherapy with the Assistance of An Electromagnetic (EM) Tracking System

    Energy Technology Data Exchange (ETDEWEB)

    Damato, AL; Bhagwat, MS; Buzurovic, I; Devlin, PM; Friesen, S; Hansen, JL; Kapur, T; Lee, LJ; Mehrtash, A; Nguyen, PL; O' Farrell, D; Wang, W; Viswanathan, AN; Cormack, RA [Brigham and Women' s Hospital, Boston, MA (United States)

    2014-06-15

    Purpose: To investigate the use of a system using EM tracking, postprocessing and error-detection algorithms for measuring brachytherapy catheter locations and for detecting errors and resolving uncertainties in treatment-planning catheter digitization. Methods: An EM tracker was used to localize 13 catheters in a clinical surface applicator (A) and 15 catheters inserted into a phantom (B). Two pairs of catheters in (B) crossed paths at a distance <2 mm, producing an undistinguishable catheter artifact in that location. EM data was post-processed for noise reduction and reformatted to provide the dwell location configuration. CT-based digitization was automatically extracted from the brachytherapy plan DICOM files (CT). EM dwell digitization error was characterized in terms of the average and maximum distance between corresponding EM and CT dwells per catheter. The error detection rate (detected errors / all errors) was calculated for 3 types of errors: swap of two catheter numbers; incorrect catheter number identification superior to the closest position between two catheters (mix); and catheter-tip shift. Results: The averages ± 1 standard deviation of the average and maximum registration error per catheter were 1.9±0.7 mm and 3.0±1.1 mm for (A) and 1.6±0.6 mm and 2.7±0.8 mm for (B). The error detection rate was 100% (A and B) for swap errors, mix errors, and shift >4.5 mm (A) and >5.5 mm (B); errors were detected for shifts on average >2.0 mm (A) and >2.4 mm (B). Both mix errors associated with undistinguishable catheter artifacts were detected and at least one of the involved catheters was identified. Conclusion: We demonstrated the use of an EM tracking system for localization of brachytherapy catheters, detection of digitization errors and resolution of undistinguishable catheter artifacts. Automatic digitization may be possible with a registration between the imaging and the EM frame of reference. Research funded by the Kaye Family Award 2012.

  8. Transbronchial Catheter Drainage via Fiberoptic Bronchoscope in Intractable Lung Abscess

    Science.gov (United States)

    Jeong, Man Pyo; Kim, Woo Sung; Han, Sung Koo; Shim, Young Soo; Kim, Keun Youl; Han, Yong Chol

    1989-01-01

    The use of the fiberoptic bronchoscope as a drainage procedure for lung abscess has become more and more widespread. We have recently adopted the technique of inserting a simple polyethylene catheter through the flexible fiberoptic bronchoscope into the abscess cavity of 11 patients with lung absess. All cases had not responded to aggressive postural drainage and adequate antibiotic therapy for at least a week. The results were as follows: Among 11 patients, the therapeutic response was dramatic in 6 patients.In the successful group, the abscess sizes were greater than 8cm in diameter and the air-fluid levels were higher than two-thirds of the cavity.Additional diagnoses, other than bacterial lung abscess, could be made in 2 cases when otherwise the diagnosis would have remained in doubt. The authors suggest that catheter drainage via fiberoptic bronchoscpope is an effective treatment modality in the large lung abscess with a high air-fluid level which is intractable to other medical approaches, and it is also a safe procedure. PMID:2487405

  9. The efficacy of noble metal alloy urinary catheters in reducing catheter-associated urinary tract infection

    Directory of Open Access Journals (Sweden)

    Alanood Ahmed Aljohi

    2016-01-01

    Results: A 90% relative risk reduction in the rate of CAUTI was observed with the noble metal alloy catheter compared to the standard catheter (10 vs. 1 cases, P = 0.006. When considering both catheter-associated asymptomatic bacteriuria and CAUTI, the relative risk reduction was 83% (12 vs. 2 cases, P = 0.005. In addition to CAUTI, the risk of acquiring secondary bacteremia was lower (100% for the patients using noble metal alloy catheters (3 cases in the standard group vs. 0 case in the noble metal alloy catheter group, P = 0.24. No adverse events related to any of the used catheters were recorded. Conclusion: Results from this study revealed that noble metal alloy catheters are safe to use and significantly reduce CAUTI rate in ICU patients after 3 days of use.

  10. Button self-retaining drainage catheter

    International Nuclear Information System (INIS)

    Caridi, James G.; Hawkins, Irvin F.; Akins, E. William; Young, Ronald S.

    1997-01-01

    To help improve patient acceptance of long-term internal/external catheter access to the biliary tract in those with benign biliary obstruction, a simple design allows the catheter end to remain flush with the skin. It consists of a clothes button affixed to the drainage catheter with a wood screw after the catheter has been cut off at the skin exit. This button/screw device has been used successfully in 22 patients over the last 10 years; catheter exchanges were easily accomplished

  11. Knowledge and Practice of Hemodialysis Amongst Dialysis Nurses.

    Science.gov (United States)

    Manandhar, Dhiraj Narayan; Chhetri, Pramod Kumar; Poudel, Prakash; Baidya, Samir Keshari; Agrawaal, Krishna Kumar

    2017-01-01

    Dialysis nurses should have a good knowledge regarding hemodialysis treatment. The status of Nepalese dialysis nurses on this aspect is unknown. This study was done to assess the knowledge and practice on different aspects of the hemodialysis treatment. We distributed validated questionnaires to the participants in a biannual conference in Kathmandu on 24th September as most of the dialysis nurses attend the event. We calculated mean and standard deviation for continuous variables and frequencies and percentage for the responses and compared counseling with different parameters. Total 94 out of 116 participants who were giving care to dialysis patients were in the study. Total 39 (42%) received formal nursing training in hemodialysis and 71 (78%) respondents always counseled patients regarding fluid intake. A total of 37 (96%) trained nurses always counseled the importance of regular dialysis. Seventy-six (81.7%) respondents did counseling on vaccination against Hepatitis B. Counseling on vaccination against influenza and pneumococcus was 47 (50%). When comparing educational status, respondents below bachelor level did more frequent counseling than level above (P=0.03). All the respondents knew the importance of hand washing and BP monitoring during hemodialysis. Ninety-one (96.7%) respondents knew how to deal with BP changes during hemodialysis. Seventy-three (77.6%) respondents were very confident on managing complications. Only 31 (33%) respondents knew how to deal with patients on continuous ambulatory peritoneal dialysis. Dialysis nurses have knowledge on basic procedures of hemodialysis but there is a space for improvement in dealing with complications to provide quality service to hemodialysis patients.

  12. Implantation port-catheter permanent indwelling of pulmonary artery in treating lung metastasis from HCC

    International Nuclear Information System (INIS)

    Cheng Jiemin; Wang Jianhua; Yan Zhiping; Wang Xiaolin; Gong Gaoquan; Liu Qingxin

    2000-01-01

    Objective: To observe the efficacy of a percutaneous implantation port-catheter permanent indwelling pulmonary artery for regional chemotherapy of the metastatic lung cancer from HCC. Methods: Between 1995 and 1999, 62 patients (42 males, 20 females; mean age 46 years) suffering from the metastatic lung cancer from HCC underwent percutaneous implantation of port-catheter permanent indwelling pulmonary artery using the right subclavian vein. In 19 patients with metastatic tumor located on one side of the lung, an indwelling catheter was placed into the ipsilateral side pulmonary artery. With metastasis of both sides, the catheter was inserted into the main trunk of pulmonary artery. The regimens of the chemotherapy were 5-FU + CDDP + MMC(FDM) or 5-FU + CDDP + MMC(FDA). Results: The interventional procedure was successfully completed in all 62 cases (100%). The complications occurred in 8% cases, including infections (3.2%), unhealed wound (1.6%) and pneumothorax (3.2%). The treatment effects of 3-months after the procedure were as follows: the obvious decrease of lung tumor size was 35.5%; stable disease (SD) 32.3% and progressive disease (PD) 32.3%. 6 months follow-up: 12 patients were dead (12/62) and the others are still doing well. The response rates were 22.6%, partial response (PR) 32.3%; stable disease (SD) 25.8% and progressive disease (PD) 32.3%. Conclusions: The percutaneous implantation techniques of pulmonary arterial port-catheter could be a good method in the treatment of metastatic lung cancer from HCC because of it is simple, with few complications and positive effect

  13. Influence of combination hemodialysis/hemoperfusion against score of depression in regular hemodialysis patients

    Science.gov (United States)

    Permatasari, T. D.; Thamrin, A.; Hanum, H.

    2018-03-01

    Patients with chronic kidney disease, have a higher risk for psychological distress such as anxiety, depression and cognitive decline. Combination of Hemodialysis (HD)/hemoperfusion (HP) regularly able to eliminate uremic toxin with mild-to-large molecular weight better. HD/HP can remove metabolites, toxin, and pathogenic factors and regulate the water, electrolyte and acid-base balance to improve the quality of patient’s sleep and appetite also reduces itching of the skin, which in turn improve the quality and life expectancy. This research was a cross sectional research with a pre-experimental design conducted from July to September 2015 with 17 regular hemodialysis patients as samples. Inclusion criteria were regular hemodialysis patients and willingly participated in the research. The assessmentwas conducted using BDI to assess depression. To obtained the results, data were analyzed using T-Test and showed that that the average BDI score before the combination of HD/HP 18.59±9 to 8.18±2.83 after the combination (p<0.001). In conclusion, combination HD/HP can lower depression scores in patients with regular HD.

  14. How effective is tetracaine 4% gel, before a peripherally inserted central catheter, in reducing procedural pain in infants: a randomized double-blind placebo controlled trial [ISRCTN75884221

    Directory of Open Access Journals (Sweden)

    Blanchard Colline

    2006-05-01

    Full Text Available Abstract Background Procedural pain relief is sub-optimal in infants, especially small and vulnerable ones. Tetracaine gel 4% (Ametop®, Smith-Nephew provides pain relief in children and larger infants, but its efficacy in smaller infants and for peripherally inserted central catheters (PICC remains uncertain. The objective of this trial was to assess the safety and efficacy of tetracaine gel on the pain response of very low birth weight (VLBW infants during insertion of a PICC. Methods Medically stable infants greater than or equal to 24 weeks gestation, requiring a non-urgent PICC, were included. Following randomization and double blinding, 1.1 g of tetracaine or placebo was applied to the skin for 30 minutes. The PICC was inserted according to a standard protocol. Pain was assessed using the Premature Infant Pain Profile (PIPP. A 3-point change in the pain score was considered clinically significant, leading to a sample size of 54 infants, with 90% statistical power. Local skin reactions and immediate adverse cardiorespiratory events were noted. The primary outcome, PIPP score at 1 minute, was analysed using an independent Student's t-test. Results Fifty-four infants were included, 27 +/- 2 weeks gestation, 916 +/- 292 grams and 6.5 +/- 3.2 days of age. Baseline characteristics were similar between groups. The mean PIPP score in the first minute was 10.88 in the treatment group as compared to 11.74 in the placebo group (difference 0.86, 95% CI -1.86, 3.58. Median duration of crying in non-intubated infants was 181 seconds in the tetracaine group compared to 68 seconds in the placebo group (difference -78, 95% CI -539, 117. Local skin erythema was observed transiently in 4 infants (3 in the treatment and 1 in the placebo group. No serious harms were observed. Conclusion Tetracaine 4% when applied for 30 minutes was not beneficial in decreasing procedural pain associated with a PICC in very small infants.

  15. Application of new balloon catheters in the treatment of congenital heart defects

    Directory of Open Access Journals (Sweden)

    Roland Fiszer

    2016-08-01

    Full Text Available Introduction : Balloon angioplasty (BAP and aortic or pulmonary balloon valvuloplasty (BAV, BPV are well-established treatment options in congenital heart defects. Recently, significant technological progress has been made and new catheters have been implemented in clinical practice. Aim: To analyze the results of BAP, BAV and BPV with the new balloon catheter Valver and its second generation Valver II, which the company Balton (Poland launched and developed. These catheters have not been clinically evaluated yet. Material and methods: We performed 64 interventions with Valver I and Valver II. With Valver I the following procedures were performed: 17 BPV (including 9 in tetralogy of Fallot – TOF, 10 BAV and 27 BAP in coarctations of the aorta (CoA – including 9 native and 18 after surgery. With Valver II ten interventions were done – 3 BPV, 2 pulmonary supravalvular BAP (after switch operations, 2 BAP of recoarctations and 3 other BAP. Age of the patients ranged from a few days to 40 years. Results: All procedures were completed successfully, without rupture of any balloon catheters. The pressure gradient drop was statistically significant in all groups: BPV in isolated pulmonary valvular stenosis 28.1 mm Hg (mean, BPV in TOF 18.7 mm Hg, BAV 32.8 mm Hg, BAP in native CoA 15.4 mm Hg and in recoarctations 18.6 mm Hg. In 3 cases during rapid deflation of Valver I, wrinkles of the balloons made it impossible to insert the whole balloon into the vascular sheath (all were removed surgically from the groin. No such complication occured with Valver II. Conclusions : Valver balloon catheters are an effective treatment modality in different valvular and vascular stenoses.

  16. Influence of the hole geometry on the flow distribution in ventricular catheters for hydrocephalus.

    Science.gov (United States)

    Giménez, Ángel; Galarza, Marcelo; Pellicer, Olga; Valero, José; Amigó, José M

    2016-07-15

    Hydrocephalus is a medical condition consisting of an abnormal accumulation of cerebrospinal fluid within the brain. A catheter is inserted in one of the brain ventricles and then connected to an external valve to drain the excess of cerebrospinal fluid. The main drawback of this technique is that, over time, the ventricular catheter ends up getting blocked by the cells and macromolecules present in the cerebrospinal fluid. A crucial factor influencing this obstruction is a non-uniform flow pattern through the catheter, since it facilitates adhesion of suspended particles to the walls. In this paper we focus on the effects that tilted holes as well as conical holes have on the flow distribution and shear stress. We have carried out 3D computational simulations to study the effect of the hole geometry on the cerebrospinal fluid flow through ventricular catheters. All the simulations were done with the OpenFOAM® toolbox. In particular, three different groups of models were investigated by varying (i) the tilt angles of the holes, (ii) the inner and outer diameters of the holes, and (iii) the distances between the so-called hole segments. The replacement of cylindrical holes by conical holes was found to have a strong influence on the flow distribution and to lower slightly the shear stress. Tilted holes did not involve flow distribution changes when the hole segments are sufficiently separated, but the mean shear stress was certainly reduced. The authors present new results about the behavior of the fluid flow through ventricular catheters. These results complete earlier work on this topic by adding the influence of the hole geometry. The overall objective pursued by this research is to provide guidelines to improve existing commercially available ventricular catheters.

  17. Designing a model to minimize inequities in hemodialysis facilities distribution

    Directory of Open Access Journals (Sweden)

    Teresa M. Salgado

    2011-11-01

    Full Text Available Portugal has an uneven, city-centered bias in the distribution of hemodialysis centers found to contribute to health care inequities. A model has been developed with the aim of minimizing access inequity through the identification of the best possible localization of new hemodialysis facilities. The model was designed under the assumption that individuals from different geographic areas, ceteris paribus, present the same likelihood of requiring hemodialysis in the future. Distances to reach the closest hemodialysis facility were calculated for every municipality lacking one. Regions were scored by aggregating weights of the “individual burden”, defined as the burden for an individual living in a region lacking a hemodialysis center to reach one as often as needed, and the “population burden”, defined as the burden for the total population living in such a region. The model revealed that the average travelling distance for inhabitants in municipalities without a hemodialysis center is 32 km and that 145,551 inhabitants (1.5% live more than 60 min away from a hemodialysis center, while 1,393,770 (13.8% live 30-60 min away. Multivariate analysis showed that the current localization of hemodialysis facilities is associated with major urban areas. The model developed recommends 12 locations for establishing hemodialysis centers that would result in drastically reduced travel for 34 other municipalities, leaving only six (34,800 people with over 60 min of travel. The application of this model should facilitate the planning of future hemodialysis services as it takes into consideration the potential impact of travel time for individuals in need of dialysis, as well as the logistic arrangements required to transport all patients with end-stage renal disease. The model is applicable in any country and health care planners can opt to weigh these two elements differently in the model according to their priorities.

  18. Hemodialysis, plea of availability versus adequecy gezira experience

    African Journals Online (AJOL)

    Methods: Pre and post hemodialysis blood sample were obtained from the study ... duration of hemodialysis session, increase blood flow rate and dialysate flow rate. ... renal replacement therapy (peritoneal dialysis and renal transplantations).

  19. Predictors of nonfunctional arteriovenous access at hemodialysis initiation and timing of access creation: A registry-based study.

    Directory of Open Access Journals (Sweden)

    Natalia Alencar de Pinho

    Full Text Available Determinants of nonfunctional arteriovenous (AV access, including timing of AV access creation, have not been sufficiently described. We studied 29 945 patients who had predialysis AV access placement and were included in the French REIN registry from 2005 through 2013. AV access was considered nonfunctional when dialysis began with a catheter. We estimated crude and adjusted odds ratio (OR with 95% confidence intervals (CI of nonfunctional versus functional AV access associated with case-mix, facility characteristics, and timing of AV access creation. Analyses were stratified by dialysis start condition (planned or as an emergency and comorbidity profile. Overall, 18% patients had nonfunctional AV access at hemodialysis initiation. In the group with planned dialysis start, female gender (OR 1.43, 95% CI 1.32-1.56, diabetes (OR 1.28, 95% CI 1.15-1.44, and a higher number of cardiovascular comorbidities (OR 1.27, 95% CI 1.09-1.49, and 1.31, 1.05-1.64, for 3 and >3 cardiovascular comorbidities versus none, respectively were independent predictors of nonfunctional AV access. A higher percentage of AV access creation at the region level was associated with a lower rate of nonfunctional AV access (OR 0.98, 95% CI 0.98-0.99 per 1% increase. The odds of nonfunctional AV access decreased as time from creation to hemodialysis initiation increased up to 3 months in nondiabetic patients with fewer than 2 cardiovascular comorbidities and 6 months in patients with diabetes or 2 or more such comorbidities. In conclusion, both patient characteristics and clinical practices may play a role in successful AV access use at hemodialysis initiation. Adjusting the timing of AV access creation to patients' comorbidity profiles may improve functional AV access rates.

  20. Brachial insertion of fully implantable venous catheters for chemotherapy: complications and quality of life assessment in 35 patients.

    Science.gov (United States)

    Fonseca, Igor Yoshio Imagawa; Krutman, Mariana; Nishinari, Kenji; Yazbek, Guilherme; Teivelis, Marcelo Passos; Bomfim, Guilherme André Zottele; Cavalcante, Rafael Noronha; Wolosker, Nelson

    2016-01-01

    To prospectively evaluate the perioperative safety, early complications and satisfaction of patients who underwent the implantation of central catheters peripherally inserted via basilic vein. Thirty-five consecutive patients with active oncologic disease requiring chemotherapy were prospectively followed up after undergoing peripheral implantation of indwelling venous catheters, between November 2013 and June 2014. The procedures were performed in the operating room by the same team of three vascular surgeons. The primary endpoints assessed were early postoperative complications, occurring within 30 days after implantation. The evaluation of patient satisfaction was based on a specific questionnaire used in previous studies. In all cases, ultrasound-guided puncture of the basilic vein was feasible and the procedure successfully completed. Early complications included one case of basilic vein thrombophlebitis and one case of pocket infection that did not require device removal. Out of 35 patients interviewed, 33 (94.3%) would recommend the device to other patients. Implanting brachial ports is a feasible option, with low intraoperative risk and similar rates of early postoperative complications when compared to the existing data of the conventional technique. The patients studied were satisfied with the device and would recommend the procedure to others. Avaliar prospectivamente segurança perioperatória, complicações precoces e grau de satisfação de pacientes submetidos ao implante de cateteres centrais de inserção periférica pela veia basílica. Foram acompanhados prospectivamente e submetidos ao implante de cateteres de longa permanência de inserção periférica, entre novembro de 2013 e junho de 2014, 35 pacientes consecutivos com doença oncológica ativa necessitando de quimioterapia. Os procedimentos foram realizados em centro cirúrgico por uma mesma equipe composta por três cirurgiões vasculares. Os desfechos primários avaliados foram as

  1. Exploring relationships of catheter-associated urinary tract infection and blockage in people with long-term indwelling urinary catheters.

    Science.gov (United States)

    Wilde, Mary H; McMahon, James M; Crean, Hugh F; Brasch, Judith

    2017-09-01

    To describe and explore relationships among catheter problems in long-term indwelling urinary catheter users, including excess healthcare use for treating catheter problems. Long-term urinary catheter users experience repeated problems with catheter-related urinary tract infection and blockage of the device, yet little has been reported of the patterns and relationships among relevant catheter variables. Secondary data analysis was conducted from a sample in a randomised clinical trial, using data from the entire sample of 202 persons over 12 months' participation. Descriptive statistics were used to characterise the sample over time. Zero-inflated negative binomial models were employed for logistic regressions to evaluate predictor variables of the presence/absence and frequencies of catheter-related urinary tract infection and blockage. Catheter-related urinary tract infection was marginally associated with catheter blockage. Problems reported at least once per person in the 12 months were as follows: catheter-related urinary tract infection 57%, blockage 34%, accidental dislodgment 28%, sediment 87%, leakage (bypassing) 67%, bladder spasms 59%, kinks/twists 42% and catheter pain 49%. Regression analysis demonstrated that bladder spasms were significantly related to catheter-related urinary tract infection and sediment amount, and catheter leakages were marginally significantly and positively related to catheter-related urinary tract infection. Frequencies of higher levels of sediment and catheter leakage were significantly associated with higher levels of blockage, and being female was associated with fewer blockages. Persons who need help with eating (more disabled) were also more likely to have blockages. Catheter-related urinary tract infection and blockage appear to be related and both are associated with additional healthcare expenditures. More research is needed to better understand how to prevent adverse catheter outcomes and patterns of problems in

  2. Virtual Breakthrough Series, Part 1: Preventing Catheter-Associated Urinary Tract Infection and Hospital-Acquired Pressure Ulcers in the Veterans Health Administration.

    Science.gov (United States)

    Zubkoff, Lisa; Neily, Julia; King, Beth J; Dellefield, Mary Ellen; Krein, Sarah; Young-Xu, Yinong; Boar, Shoshana; Mills, Peter D

    2016-11-01

    In 2014 the Veterans Health Administration (VHA) of the Department of Veterans Affairs (VA) implemented a Virtual Breakthrough Series (VBTS) collaborative to help VHA facilities prevent hospital-acquired conditions: catheter-associated urinary tract infection (CAUTI) and hospital-acquired pressure ulcers (HAPUs). During the prework phase, participating facilities assembled a multidisciplinary team, assessed their current system for CAUTI or HAPU prevention, and examined baseline data to set improvement aims. The action phase consisted of educational conference calls, coaching, and monthly team reports. Learning was conducted via phone, web-based options, and e-mail. The CAUTI bundle focused on four key principles: (1) avoidance of indwelling urinary catheters, (2) proper insertion technique, (3) proper catheter maintenance, and (4) timely removal of the indwelling catheter. The HAPU bundle focused on assessment and inspection, pressure-relieving surfaces, turning and repositioning, incontinence management, and nutrition/hydration assessment and intervention. For the 18 participating units, the mean aggregated CAUTI rate decreased from 2.37 during the prework phase to 1.06 per 1,000 catheter-days during the action (implementation) phase (p model for implementing a virtual model for improvement. Copyright 2016 The Joint Commission.

  3. Intrathecal catheter-syringe adaptor for short-term intrathecal analgesia with an externalized pump: a case report.

    Science.gov (United States)

    Wilkes, Denise; Cook, Michael; Solanki, Daneshvari

    2010-01-01

    In most patients, cancer pain is effectively treated with conservative medical management consisting of oral and/or transdermal analgesics. Cancer patients tend to fail conservative medical management near the end of their life expectancy, thus requiring alternative routes of analgesia such as intravenous, epidural, or intrathecal. The intrathecal route provides the most effective analgesia due to the close proximity of the opioid receptors in the spinal cord. Though there are many techniques that exist for intrathecal drug delivery, complications can limit effectiveness such as infection, bleeding, cerebrospinal fluid (CSF) leaks, post-dural puncture headaches (PDPH), pump and/or catheter malfunctions, or limitations of technical expertise. Therefore, an important goal in palliative cancer pain therapy is to use equipment that is going to have the fewest number of complications and will be the most familiar to the health care providers. We describe the combination of the Medtronic Indura 1P catheter, which has the least catheter-related complications and can be used with any external drug infusion pump. These are regular infusion pumps that the health care workers are familiar with so they can provide excellent and efficient service to the patient. In an operating room, the intrathecal catheter was placed using sterile technique under fluoroscopic guidance. The epidural space was identified with loss of resistance technique. Then the introducer needle (supplied in the Indura 1P catheter kit) was advanced until free-flowing CSF was obtained. The spinal catheter was advanced into the intrathecal space through the introducer needle to lumbar 2-3 level. The catheter was tunneled subcutaneously 10 cm lateral to the catheter exit site. A syringe filling device was inserted into the catheter opening and was secured with silk suture. A luer lock syringe was attached to the syringe filling device and CSF was aspirated. The syringe filling device was capped and later

  4. Depression in hemodialysis patients

    International Nuclear Information System (INIS)

    Anees, M.; Barki, H.; Masood, M.

    2008-01-01

    To measure the frequency of depression and its risk factors in patients under going hemodialysis. It is a cross-sectional prospective study conducted at Hemodialysis unit of Shalamar Hospital and Shaikh Zayed Hospital, Lahore from 1/sup st/ January 2006 to 30/sup th/ April 2006. All patients getting regular hemodialysis for more than three months were included. Beck's Depression Inventory- II (BDI-II; adapted in Urdu) was administered on all the patients who were able to read or understand it. Blood sample were drawn at the same time for routine hematological, biochemical parameters and viral markers (Anti HCV and HbsAg). Diagnosis was made as per Diagnostic and Statistical Manual of Mental Disorders, fourth edition (DSM IV) for correlation of psychological variables with clinical, hematological and biochemical parameters. Eighty nine patients were enrolled which included fifty two (58.4%) were male and seventy seven (86.5%) were married. Major causes of renal failure were diabetes, hypertension and chronic glomerulonephrotis. Duration of dialysis was from 03 to 49 months with mean of 19.64 +- 11.7 months. Severity of depression was categorized in to mild, moderate and severe on the basis of BDI score. Majority of the patients fifty (56.1%) were moderately to severely depressed and there was no gender difference in the prevalence of depression. Majority of patients undergoing hemodialysis were depressed. Major risk factors for depression were marital status, illiteracy, number of children, socioeconomic factors, gender, hypertension and hypoalbuminemia. Patients with anemia, hyponatremia and hyperkalemia had suicidal tendency. Patients with hepatitis C and disturbed liver function have strong correlation with psychological parameters. (author)

  5. 78 FR 25747 - Gastroenterology and Urology Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2013-05-02

    ... Devices and Radiological Health, Food and Drug Administration, 10903 New Hampshire Ave., Silver Spring, MD... as catheters, cannulae or hollow needles. Chronic hemodialysis catheters are soft, blunt-tipped...

  6. Treatment of hemodialysis vascular access rupture irresponsive to prolonged balloon tamponade: Retrospective evaluation of the effectiveness of N-butyl cyanoacrylate seal-off technique

    Energy Technology Data Exchange (ETDEWEB)

    Weng, Mei Jul; Liang, Huei Lung; Pan, Huay Ben [Dept. of Radiology, Kaohsiung Veterans General Hospital, Kaohsiung (China); Chen, Matt Chiung Yu [Dept. of Radiology, Yuan' s General Hospital, Kaohsiung (China)

    2013-01-15

    The current study retrospectively evaluated whether the percutaneous N-butyl cyanoacrylate (NBCA) seal-off technique is an effective treatment for controlling the angioplasty-related ruptures, which are irresponsive to prolonged balloon tamponade, during interventions for failed or failing hemodialysis vascular accesses. We reviewed 1588 interventions performed during a 2-year period for dysfunction and/or failed hemodialysis vascular access sites in 1569 patients. For the angioplasty-related ruptures, which could not be controlled with repeated prolonged balloon tamponade, the rupture sites were sealed off with an injection of a glue mixture (NBCA and lipiodol), via a needle/needle sheath to the rupture site, under a sonographic guidance. Technical success rate, complications and clinical success rate were reported. The post-seal-off primary and secondary functional patency rates were calculated by a survival analysis with the Kaplan-Meier method. Twenty ruptures irresponsive to prolonged balloon tamponade occurred in 1588 interventions (1.3%). Two technical failures were noted; one was salvaged with a bailout stent-graft insertion and the other was lost after access embolization. Eighteen accesses (90.0%) were salvaged with the seal-off technique; of them, 16 ruptures were completely sealed off, and two lesions were controlled as acute pseudoaneurysms. Acute pseudoaneurysms were corrected with stentgraft insertion in one patient, and access ligation in the other. The most significant complication during the follow-up was delayed pseudoaneurysm, which occurred in 43.8% (7 of 16) of the completely sealed off accesses. Delayed pseudoaneurysms were treated with surgical revision (n = 2), access ligation (n = 2) and observation (n = 3). During the follow-up, despite the presence of pseudoaneurysms (acute = 1, delayed = 7), a high clinical success rate of 94.4% (17 of 18) was achieved, and they were utilized for hemodialysis at the mean of 411.0 days. The post

  7. Reconstruction of Intima and Adventitia Models into a State Undeformed by a Catheter by Using CT, IVUS, and Biplane X-Ray Angiogram Images

    Directory of Open Access Journals (Sweden)

    Jinwon Son

    2017-01-01

    Full Text Available The number of studies on blood flow analysis using fluid-structure interaction (FSI analysis is increasing. Though a 3D blood vessel model that includes intima and adventitia is required for FSI analysis, there are difficulties in generating it using only one type of medical imaging. In this paper, we propose a 3D modeling method for accurate FSI analysis. An intravascular ultrasound (IVUS image is used with biplane X-ray angiogram images to calculate the position and orientation of the blood vessel. However, these images show that the blood vessel is deformed by the catheter inserted into the blood vessel for IVUS imaging. To eliminate such deformation, a CT image was added and the two models were registered. First, a 3D model of the undeformed intima was generated using a CT image. In the second stage, a model of intima and adventitia deformed by the catheter was generated by combining the IVUS image and the X-ray angiogram images. A 3D model of intima and adventitia with the deformation caused by insertion of the catheter eliminated was generated by matching these 3D blood vessel models in different states. In addition, a 3D blood vessel model including bifurcation was generated using the proposed method.

  8. Peritoneal catheter fixation combined with straight upward tunnel and low implant position to prevent catheter malfunction.

    Science.gov (United States)

    Zhang, Qingyan; Jiang, Chunming; Zhu, Wei; Sun, Cheng; Xia, Yangyang; Tang, Tianfeng; Wan, Cheng; Shao, Qiuyuan; Liu, Jing; Jin, Bo; Zhang, Miao

    2018-03-01

    Catheter malfunction is the main reason for early peritoneal dialysis (PD) technique failure. This study aimed to evaluate the effect of a new surgery technique with catheter fixation to the lower abdominal wall combined with straight upward tunnel and low implant position in reducing catheter malfunction. Patients with end stage renal disease who received PD in our centre from January 2013 to December 2015 were involved in this study. They were randomly divided into three groups according to surgical technique: traditional open surgery group, modified open surgery group and modified open surgery with catheter fixation group. All patients were followed up for six months after surgery. Catheter- related complications were analyzed. A total of 152 patients were involved. Among them, 49 received traditional open surgery (TOS group), 49 received modified open surgery (MOS group), and 54 received modified open surgery with catheter fixation (MOS-F group). During follow-up, no patients (0%) in MOS-F group developed catheter malfunction which was significantly lower than that of the TOS group (0 vs 16.33%, P = 0.002). Although not statistically significant, the incidence of catheter malfunction was lower in MOS-F group than that in MOS group (0 vs 4.08%, P = 0.134). No significant difference was observed in the episodes of infection, bleeding, leakage, inflow or outflow pain, hernia and delayed wound healing among the three groups (all P > 0.05). Catheter fixation combined with straight upward tunnel and low implant position can effectively prevent catheter malfunction in PD catheter placement. © 2016 Asian Pacific Society of Nephrology.

  9. Establishing Core Outcome Domains in Hemodialysis: Report of the Standardized Outcomes in Nephrology-Hemodialysis (SONG-HD) Consensus Workshop.

    Science.gov (United States)

    Tong, Allison; Manns, Braden; Hemmelgarn, Brenda; Wheeler, David C; Evangelidis, Nicole; Tugwell, Peter; Crowe, Sally; Van Biesen, Wim; Winkelmayer, Wolfgang C; O'Donoghue, Donal; Tam-Tham, Helen; Shen, Jenny I; Pinter, Jule; Larkins, Nicholas; Youssouf, Sajeda; Mandayam, Sreedhar; Ju, Angela; Craig, Jonathan C

    2017-01-01

    Evidence-informed decision making in clinical care and policy in nephrology is undermined by trials that selectively report a large number of heterogeneous outcomes, many of which are not patient centered. The Standardized Outcomes in Nephrology-Hemodialysis (SONG-HD) Initiative convened an international consensus workshop on November 7, 2015, to discuss the identification and implementation of a potential core outcome set for all trials in hemodialysis. The purpose of this article is to report qualitative analyses of the workshop discussions, describing the key aspects to consider when establishing core outcomes in trials involving patients on hemodialysis therapy. Key stakeholders including 8 patients/caregivers and 47 health professionals (nephrologists, policymakers, industry, and researchers) attended the workshop. Attendees suggested that identifying core outcomes required equitable stakeholder engagement to ensure relevance across patient populations, flexibility to consider evolving priorities over time, deconstruction of language and meaning for conceptual consistency and clarity, understanding of potential overlap and associations between outcomes, and an assessment of applicability to the range of interventions in hemodialysis. For implementation, they proposed that core outcomes must have simple, inexpensive, and validated outcome measures that could be used in clinical care (quality indicators) and trials (including pragmatic trials) and endorsement by regulatory agencies. Integrating these recommendations may foster acceptance and optimize the uptake and translation of core outcomes in hemodialysis, leading to more informative research, for better treatment and improved patient outcomes. Copyright © 2016 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.

  10. Establishing Core Outcome Domains in Hemodialysis: Report of the Standardized Outcomes in Nephrology−Hemodialysis (SONG-HD) Consensus Workshop

    Science.gov (United States)

    Tong, Allison; Manns, Braden; Hemmelgarn, Brenda; Wheeler, David C.; Evangelidis, Nicole; Tugwell, Peter; Crowe, Sally; Van Biesen, Wim; Winkelmayer, Wolfgang C.; O’Donoghue, Donal; Tam-Tham, Helen; Shen, Jenny; Pinter, Jule; Larkins, Nicholas; Youssouf, Sajeda; Mandayam, Sreedhar; Ju, Angela; Craig, Jonathan C.

    2017-01-01

    Evidence-informed decision-making in clinical care and policy in nephrology is undermined by trials that selectively report a large number of heterogeneous outcomes, many of which are not patient-centered. The Standardized Outcomes in Nephrology−Hemodialysis (SONG-HD) Initiative convened an international consensus workshop on November 7, 2015, to discuss the identification and implementation of a potential core outcome set for all trials in hemodialysis. The purpose of this article is to report qualitative analyses of the workshop discussions, describing the key aspects to consider when establishing core outcomes in trials involving patients on hemodialysis. Key stakeholders including eight patients/caregivers and 47 health professionals (nephrologists, policy makers, industry, researchers) attended the workshop. Attendees suggested that identifying core outcomes required equitable stakeholder engagement to ensure relevance across patient populations; flexibility to consider evolving priorities over time; deconstruction of language and meaning for conceptual consistency and clarity; understanding of potential overlap and associations between outcomes; and an assessment of applicability to the range of interventions in hemodialysis. For implementation, they proposed that core outcomes must have simple, inexpensive and validated outcome measures that could be used in clinical care (quality ndicators) and trials (including pragmatic trials), and endorsement by regulatory agencies. Integrating these recommendations may foster acceptance and optimize the uptake and translation of core outcomes in hemodialysis, leading to more informative research, for better treatment, and improved patient outcomes. PMID:27497527

  11. Effect of Hemodialysis on Left and Right Ventricular Volume and Function

    International Nuclear Information System (INIS)

    Han, Jin Suk; Koh, Chang Soon

    1985-01-01

    With the improvement of hemodialysis, the course of thc discase in patient with endstage renal disease has been clearly improved. Nevertheless, among several shortcomings to our present mode of renal replacement therapy, cardiovascular complications have been the leading cause of morbidity and mortality. Several factors such as anemia, arteriovenous shunting of blood, intermittent extracorporeal circulation and hypertension may be contributing. But little is known about the quantitative cardiac hemodynamic characteristics occurred during hemodialysis. The purpose of this study is to observe the sequential hemodynamic changes before, during and after the hemodialysis and to investigate: reliable parameters in the detection of ventricular dysfunction. In the present study, equilibrium radionuclide cardiac angiography was performed and left and right ventricular volume indices, ejection phase indices of both ventricular, performance were measured in the 16 stable patients with chronic renal failure treated with maintenance hemodialysis sequentially i.e. before, during (carly and late phase) and after the hemodialysis. The results obtained were as follows; 1) The indices of the left ventricular function were not changed during the hemodialysis but increased after the hemodialysis. 2) The indices of the right ventricular function(EF, SVI) were significantly decreased in the early phase (15, 30 minutes after starting extracorporeal circulation) but recovered after the hemodialysis, 3) The ratio of right ventricular to left ventricular ejection fraction was significantly decreased in the early phase and the lung volume indices were significantly increased at the same phase. As a conclusion, hemodialysis improves left ventricular function maybe du to increased contractility, and effects on the right ventricular function maybe due to the increased lung volume in the early phase of hemodialysis.

  12. Effect of Hemodialysis on Left and Right Ventricular Volume and Function

    Energy Technology Data Exchange (ETDEWEB)

    Han, Jin Suk; Koh, Chang Soon [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1985-09-15

    With the improvement of hemodialysis, the course of thc discase in patient with endstage renal disease has been clearly improved. Nevertheless, among several shortcomings to our present mode of renal replacement therapy, cardiovascular complications have been the leading cause of morbidity and mortality. Several factors such as anemia, arteriovenous shunting of blood, intermittent extracorporeal circulation and hypertension may be contributing. But little is known about the quantitative cardiac hemodynamic characteristics occurred during hemodialysis. The purpose of this study is to observe the sequential hemodynamic changes before, during and after the hemodialysis and to investigate: reliable parameters in the detection of ventricular dysfunction. In the present study, equilibrium radionuclide cardiac angiography was performed and left and right ventricular volume indices, ejection phase indices of both ventricular, performance were measured in the 16 stable patients with chronic renal failure treated with maintenance hemodialysis sequentially i.e. before, during (carly and late phase) and after the hemodialysis. The results obtained were as follows; 1) The indices of the left ventricular function were not changed during the hemodialysis but increased after the hemodialysis. 2) The indices of the right ventricular function(EF, SVI) were significantly decreased in the early phase (15, 30 minutes after starting extracorporeal circulation) but recovered after the hemodialysis, 3) The ratio of right ventricular to left ventricular ejection fraction was significantly decreased in the early phase and the lung volume indices were significantly increased at the same phase. As a conclusion, hemodialysis improves left ventricular function maybe du to increased contractility, and effects on the right ventricular function maybe due to the increased lung volume in the early phase of hemodialysis.

  13. Survival with Three-Times Weekly In-Center Nocturnal Versus Conventional Hemodialysis

    Science.gov (United States)

    Xu, Jianglin; Suri, Rita S.; Nesrallah, Gihad; Lindsay, Robert; Garg, Amit X.; Lester, Keith; Ofsthun, Norma; Lazarus, Michael; Hakim, Raymond M.

    2012-01-01

    Whether the duration of hemodialysis treatments improves outcomes remains controversial. Here, we evaluated survival and clinical changes associated with converting from conventional hemodialysis (mean=3.75 h/treatment) to in-center nocturnal hemodialysis (mean=7.85 h/treatment). All 959 consecutive patients who initiated nocturnal hemodialysis for the first time in 77 Fresenius Medical Care facilities during 2006 and 2007 were eligible. We used Cox models to compare risk for mortality during 2 years of follow-up in a 1:3 propensity score–matched cohort of 746 nocturnal and 2062 control patients on conventional hemodialysis. Two-year mortality was 19% among nocturnal hemodialysis patients compared with 27% among conventional patients. Nocturnal hemodialysis associated with a 25% reduction in the risk for death after adjustment for age, body mass index, and dialysis vintage (hazard ratio=0.75, 95% confidence interval=0.61–0.91, P=0.004). With respect to clinical features, interdialytic weight gain, albumin, hemoglobin, dialysis dose, and calcium increased on nocturnal therapy, whereas postdialysis weight, predialysis systolic blood pressure, ultrafiltration rate, phosphorus, and white blood cell count declined (all P<0.001). In summary, notwithstanding the possibility of residual selection bias, conversion to treatment with nocturnal hemodialysis associates with favorable clinical features, laboratory biomarkers, and improved survival compared with propensity score–matched controls. The potential impact of extended treatment time on clinical outcomes while maintaining a three times per week hemodialysis schedule requires evaluation in future clinical trials. PMID:22362905

  14. [Effects of midodrine on symptomatic hypotension during hemodialysis].

    Science.gov (United States)

    Cotera, Alejandro; Alvo, Miriam; Sanhueza, María Eugenia; Elgueta, Leticia; Gormaz, Juan Pablo; Ibáñez, Carlos; Cuadra, Cristián

    2002-09-01

    Hypotension occurs in 20% of hemodialysis procedures. To study the effects of midodrine on hypotension during hemodialysis. Ten patients on chronic hemodialysis and with a history of hypotension during the procedure, were studied. They received midodrine 10 mg per os or placebo during 5 dialytic procedures each, in a double blind cross over design. Blood pressure levels prior to dialysis were similar during the midodrine or placebo administration periods. During dialysis, systolic blood pressure fell 19.3 +/- 28 mmHg with midodrine and 23.4 +/- 28 mmHg with placebo. Diastolic blood pressure fell 7.3 +/- 11.5 mmHg with midodrine and 11.1 +/- 12 mmHg with placebo. The reduction in median arterial pressure was also less pronounced with midodrine. Midodrine lessens the fall in arterial pressure during hemodialysis, in patients with symptomatic hypotension.

  15. Clinical Performance of a Salivary Amylase Activity Monitor During Hemodialysis Treatment

    Directory of Open Access Journals (Sweden)

    Masaru Shimazaki

    2008-01-01

    Full Text Available The hemodialysis procedure is thought to be a physical stressor in the majority of hemodialyzed patients. Previous studies suggest that elevated salivary amylase level may correlate with increased plasma norepinephrine level under psychological and physical stress conditions. In this study, we investigated biological stress reactivity during hemodialysis treatment using salivary amylase activity as a biomarker. Seven patients (male/female = 5/2, age:67.7+ /− 5.9 years who had been receiving regular 4 h hemodialysis were recruited. Salivary amylase activity was measured using a portable analyzer every hour during the hemodialysis session. Salivary amylase activity was shown to be relatively stable and constant throughout hemodialysis, whereas there were significant changes in systolic blood pressure and pulse rate associated with blood volume reduction. Our results show that hemodialysis treatment per se dose not affect salivary amylase activity.

  16. [The role of the uretral catheter in the development of catheter- related urinary tract infection].

    Science.gov (United States)

    Vasilyev, A O; Govorov, A V; Shiryaev, A A; Pushkar, D Yu

    2017-12-01

    The most common source of nosocomial infection is the urinary tract, especially if they it is drained with a urethral catheter. Catheter-associated urinary tract infections account for at least 80% of all complicated urinary tract infections and are the most common type of hospital-acquired infection. Intestinal microflora plays the leading role in the pathogenesis of catheter-associated urinary tract infections, whereas the most important risk factor for their development is the long duration of urinary catheter drainage. In the case of short-term and intermittent catheterization, routine antibiotic prophylaxis is not required, but if a patient develops clinically significant infection, antibiotic therapy is required followed by definitive therapy based on culture. Urethral catheters coated with antimicrobial substances and anti-inflammatory agents can significantly reduce the adhesion and migration of bacteria, thereby reducing the incidence of urinary tract infections. Despite this, the incidence of catheter-associated infection remains high. We have reviewed recent literature related to catheter-associated urinary tract infections and the best means of preventing this condition.

  17. Views of Japanese patients on the advantages and disadvantages of hemodialysis and peritoneal dialysis.

    Science.gov (United States)

    Nakamura-Taira, Nanako; Muranaka, Yoshimi; Miwa, Masako; Kin, Seikon; Hirai, Kei

    2013-08-01

    The preference for dialysis modalities is not well understood in Japan. This study explored the subjective views of Japanese patients undergoing dialysis regarding their treatments. The participants were receiving in-center hemodialysis (CHD) or continuous ambulatory peritoneal dialysis (CAPD). In Study 1, 34 participants (17 CHD and 17 CAPD) were interviewed about the advantages and disadvantages of dialysis modalities. In Study 2, 454 dialysis patients (437 CHD and 17 CAPD) rated the advantages and disadvantages of CHD and CAPD in a cross-sectional survey. Interviews showed that professional care and dialysis-free days were considered as advantages of CHD, while independence, less hospital visits, and flexibility were considered as advantages of CAPD. Disadvantages of CHD included restriction of food and fluids and unpleasant symptoms after each dialysis session. Catheter care was an additional disadvantage of CAPD. Survey showed that the highly ranked advantages were professional care in CHD and less frequent hospital visits in CAPD, while the highly ranked disadvantages were concerns about emergency and time restrictions in CHD, and catheter care and difficulty in soaking in a bath in CAPD. The total scores of advantages and disadvantages showed that CHD patients subjectively rated their own modality better CHD over CAPD, while CAPD patients had the opposite opinion. The results of this study indicate that the factors affecting the decision-making process of Japanese patients are unique to Japanese culture, namely considering the trouble caused to the people around patients (e.g., families, spouses, and/or caregivers).

  18. Development of Needle Insertion Manipulator for Central Venous Catheterization

    Science.gov (United States)

    Kobayashi, Yo; Hong, Jaesung; Hamano, Ryutaro; Hashizume, Makoto; Okada, Kaoru; Fujie, Masakatsu G.

    Central venous catheterization is a procedure, which a doctor insert a catheter into the patient’s vein for transfusion. Since there are risks of bleeding from arterial puncture or pneumothorax from pleural puncture. Physicians are strictly required to make needle reach up into the vein and to stop the needle in the middle of vein. We proposed a robot system for assisting the venous puncture, which can relieve the difficulties in conventional procedure, and the risks of complication. This paper reports the design structuring and experimental results of needle insertion manipulator. First, we investigated the relationship between insertion force and angle into the vein. The results indicated that the judgment of perforation using the reaction force is possible in case where the needling angle is from 10 to 20 degree. The experiment to evaluate accuracy of the robot also revealed that it has beyond 0.5 mm accuracy. We also evaluated the positioning accuracy in the ultrasound images. The results displays that the accuracy is beyond 1.0 mm and it has enough for venous puncture. We also carried out the venous puncture experiment to the phantom and confirm our manipulator realized to make needle reach up into the vein.

  19. Predictors of Venous Thromboembolic Events Associated with Central Venous Port Insertion in Cancer Patients

    Directory of Open Access Journals (Sweden)

    Christine Hohl Moinat

    2014-01-01

    Full Text Available Insertion of central venous port (CVP catheter in the cancer population is associated with increased incidence of venous thromboembolic events (VTE. However, trials have shown limited benefit of antithrombotic treatment to prevent catheter-related venous thrombosis. This prospective observational cohort study was designed to assess the incidence of VTE closely related to CVP implantation in patients with cancer and undergoing chemotherapy, and to identify a high risk subgroup of patients. Between February 2006 and December 2011, 1097 consecutive cancer patients with first CVP implantation were included. Catheter-related VTE were defined as deep venous thrombosis in the arm, with or without pulmonary embolism (PE, or isolated PE. The incidence of CVP-associated VTE was 5.9% (IC95 4.4–7.3% at 3 months, and 11.3% (IC95 9.4–13.2% at 12 months. The incidence of any VTE was 7.6% (IC95 6.0–9.3% at 3 months, and 15.3% (IC95 13.1–17.6% at 12 months. High Khorana risk score and lung cancer were significant predictors of 3 month VTE. In conclusion, this large cohort study of patients with first CVP catheter implantation confirms the high incidence of VTE associated with the CVP implantation and allow identifying high risk patients who may benefit from thromboprophylaxis.

  20. Hepatitis C Is Less Aggressive in Hemodialysis Patients than in Nonuremic Patients

    Science.gov (United States)

    Trevizoli, Jose Eduardo; de Paula Menezes, Raissa; Ribeiro Velasco, Lara Franciele; Amorim, Regina; de Carvalho, Mauro Birche; Mendes, Liliana Sampaio; Neto, Columbano Junqueira; de Deus Macedo, José Roberto; de Assis, Francisco; Neves, Rocha

    2008-01-01

    Background and objectives: The severity of liver disease among hepatitis C patients on hemodialysis is controversial. The aim of this study was to compare the clinical, biochemical, and liver histologic characteristics of hepatitis C virus (HCV) in hemodialysis patients and in those with normal renal function. Design, setting, participants, & measurements: A case-control study was carried out with 36 HCV patients on hemodialysis and 37 HCV patients with normal renal function matched for gender, age at infection, and estimated time of infection. Results: HCV patients on hemodialysis had lower levels of alanina aminotransferase and lower viral load. Hepatic fibrosis was significantly higher in the patients with normal renal function (73%) than in hemodialysis patients (47.2%, P < 0.025); the same was observed for inflammatory activity (control group 59.5% versus hemodialysis patients 27.7%, P = 0.003). In addition, the risk of tissue inflammation was four times lower in hemodialysis patients (odds ratio = 0.23, P < 0.004), and severe inflammatory activity on biopsy was the only independent risk factor for fibrosis (P < 0.001). Conclusions: The lower biochemical and inflammatory activities observed in hemodialysis patients suggest that hemodialysis and uremia may have a protective role against progression of the disease caused by HCV. PMID:18650408

  1. Erectile Dysfunction in Males on Hemodialysis

    International Nuclear Information System (INIS)

    Haider, E.; Iftikhar, R.; Ghazanfar, A.; Afzal, M.; Mir, A. W.; Mansoor, K.; Taj, R.; Samiullah, R.

    2013-01-01

    Objective: The determine the frequency of erectile dysfunction in males on hemodialysis. Study Design: Descriptive study. Place and duration: Hemodialysis unit, Combined Military Hospital Kharian from October 2011 to April 2012. Patients and Methods: A total of 150 married male patients of end stage renal disease (ESRD) on hemodialysis were included in the study. Patients with cognitive and/or communication deficits and on hemodialysis for less than 06 months were excluded from the study. Erectile dysfunction (ED) was assessed using International Index of Erectile Function-5 (IIEF-5). Frequency of erectile dysfunction (ED) was analyzed using Statistical Package for Social Sciences (SPSS) version 17. Results: Mean age of the patients were 52.89 = 8.25 years. Mean duration of hemodialysis was 34 +- 9.62 months. The underlying etiology of end stage renal disease were diabetic nephropathy 69(46%), hypertensive nephropathy 51(34%), obstructive nephropathy 18(12%), glomerulonephritis 9(6%), autosomal polycystic kidney disease 3(2%). Mean IIEF-5 score was 13.29 +- 6.38. The frequency of erectile dysfunction was 74%. The majority of the patients, 73(48.7%) had moderate erectile dysfunction, while 24 (16%) had severe and 14 (9.3%) had mild erectile dysfunction. Out of total 150 patients enrolled, 39 (26%) patients had no erectile dysfunction. Conclusion: ED is a highly prevalent problem in men with ESRD. Physicians are urged to recognize the high prevalence of erection problems in men with ESRD and proactively question all patients regarding their sexual function. This will not only improve the recognition of this condition among these patients but also improve the quality of life after adequate treatment. (author)

  2. Clinical variables, lifestyle and coping in hemodialysis.

    Science.gov (United States)

    Comelis Bertolin, Daniela

    2016-10-01

    To verify the relationship between coping strategies of people with chronic kidney disease undergoing hemodialysis and their clinical variables and lifestyle habits. It was developed a cross-sectional study that used the Coping Strategies Inventory of Folkman and Lazarus and a semi-structured questionnaire for collecting clinical variables and lifestyles of patients undergoing hemodialysis in the Urology and Nephrology Institute of São Jose do Rio Preto-SP (Brazil). Participants were 107 adults undergoing hemodialysis, with an average age of 51 years; 62.4% were men. The main causes of chronic kidney disease were chronic glomerulonephritis, diabetes mellitus, undetermined cause and hypertension. The most reported coping strategies were focused on emotion. There were greater coping scores among people who had diabetes, those who had leisure and those who referred religion. People who exercised and those who had undergone renal transplantation had more positive coping. Clinical variables of people undergoing hemodialysis can be sources of stress, and lifestyle habits are associated with coping strategies to mitigate the effects of stress. Copyright© by the Universidad de Antioquia.

  3. [Catheter fracture and pulmonary embolization of the distal fragment: a rare complication of the totally implantable venous access port].

    Science.gov (United States)

    Rebahi, H; El Adib, A G; Mouaffak, Y; El Hattaoui, M; Chaara, A; Sadek, H; Khouchani, M; Mahmal, L; Younous, S

    2015-01-01

    Totally implantable venous access port plays a crucial role in the treatment of patients in oncology. However, its use can result sporadically in catheter fracture with catheter tip embolization into pulmonary arteries. We report this unusual but potentially serious complication in four patients. In these patients, the port had been inserted percutaneously into the subclavian vein using the infra-clavicular approach. This side effect occurred late in three patients. In all patients, the catheter fracture was asymptomatic or pauci-symptomatic and was caused by the pinch-off syndrome. The retrieval of the embolized fragments was successfully performed by transcatheter procedure in the cardiac catheterisation laboratory. We reviewed the literature and the newest guidelines and recommendations to detail the clinico-radiological features, the possible causes of this complication and discussed means to recognize, manage and prevent it. Copyright © 2013 Société nationale française de médecine interne (SNFMI). Published by Elsevier SAS. All rights reserved.

  4. In-center hemodialysis attendance: patient perceptions of risks, barriers, and recommendations.

    Science.gov (United States)

    Chenitz, Kara B; Fernando, Michael; Shea, Judy A

    2014-04-01

    Missed hemodialysis treatments lead to increased morbidity and mortality in the end-stage renal disease population. Little is known about why patients have difficulty attending their scheduled in-center dialysis treatments. Semistructured interviews with 15 adherent and 15 nonadherent hemodialysis patients were conducted to determine patients' attitudes about dialysis, health beliefs and risk perception regarding missed treatments, barriers and facilitators to hemodialysis attendance, and recommendations to improve the system to facilitate dialysis attendance. Average time on dialysis was 2.5 years for the nonadherent group and 7.3 years in the adherent group. In both groups, patients felt that dialysis is life-saving and a necessity. A substantial number of patients in both groups understood that missing hemodialysis treatments is dangerous and several patients could clearly communicate the risk of skipping. The most common barriers to hemodialysis were inadequate or unreliable transportation (mentioned in both groups) and a lack of motivation to get to dialysis or that dialysis is not a priority (typically mentioned by the nonadherent group). Facilitators to hemodialysis attendance included explanations from the health care team regarding the risk of skipping and relationships with other dialysis patients. Patient recommendations to improve dialysis attendance included continued education about the risk of poor attendance and more accessible transportation. Patients did not feel that home dialysis would improve adherence. Hemodialysis patients must adhere to a complex and burdensome regimen. Through the elucidation of barriers and facilitators to hemodialysis attendance and through specific patient recommendations, at least three interventions may be further investigated to improve hemodialysis attendance: Improvement of the transportation system, education and supportive encouragement from the health care team, and peer support mentorship. © 2014 International

  5. The Initial Vascular Access Type Contributes to Inflammation in Incident Hemodialysis Patients

    Directory of Open Access Journals (Sweden)

    Mala Sachdeva

    2012-01-01

    Full Text Available Background. The contribution of the hemodialysis (HD vascular access type to inflammation is unclear. Methods. We conducted a prospective observational study in an incident HD population. C-reactive protein (CRP, interleukin-6 (IL-6, and interferon-γ-induced protein (IP-10 were measured before and at 6-time points after access placement for 1 year. Results. Sixty-four incident HD patients were included (tunneled catheter (TC, =40, arteriovenous fistula (AVF, =14, and arteriovenous graft (AVG, =10. A mixed effects model was performed to adjust for age, sex, race, coronary artery disease, diabetes mellitus, infections, access thrombosis, initiation of HD, and days after access surgery. In comparison to AVFs, the presence of a TC was associated with significantly higher levels of CRP (=0.03, IL-6 (=0.07, and IP-10 (=0.03. The presence of an AVG was associated with increases in CRP (=0.01 and IP-10 (=0.07. Conclusions. Patients who initiate HD with a TC or an AVG have a heightened state of inflammation, which may contribute to the excess 90-day mortality after HD initiation.

  6. Effect of One versus Two Drain Insertion on Postoperative Seroma Formation after Modified Radical Mastectomy

    Directory of Open Access Journals (Sweden)

    farzaneh ebrahimifard

    2016-04-01

    Full Text Available Background: Modified radical mastectomy (MRM is still one of globally accepted surgical techniques for breast cancer and in some selected patient is the gold standard type of surgery. The most frequent complication of this procedure is seroma under skin flaps or in the axilla as reported as much as 30% in some studies. The use of closed suction drainage system to reduce the incidence of this complication has been routinely accepted by surgeons; however, length of catheter stay and the number of catheters inserted in the wound are still controversial. The present study compares the results of single versus double drain insertion in patients undergoing MRM for breast cancer.Materials and Methods: The study was conducted on 100 women with breast cancer who were candidate for MRM surgery during 2007-2010 referred to Modarres hospital, Tehran, Iran as a randomized group matched controlled trial.Results: There was no significant difference between the two groups in terms of age, BMI, and tumor weight (P=0.406 (Table 1. Similarly, the difference between the two groups was insignificant in tumor size (T and number of lymph nodes involved (P=0.145. There was no significant difference between the two groups in timing of axillary drain removal (P=0.064. No significant differences were observed between the two groups in mean aspirated fluid (P=0.071 and mean aspirated sera (P=0.484 after removal of drains.Conclusion: This study revealed one drain insertion in MRM surgery is as effective as two drain and probably less morbidity and cost.

  7. The mothers' experiences in the pediatrics hemodialysis unit.

    Science.gov (United States)

    Mieto, Fernanda Stella Risseto; Bousso, Regina Szylit

    2014-01-01

    The need for hemodialysis exerts a deep impact on the lives of children and adolescents with end-stage kidney chronic failure and their mothers, who predominantly assume the care related to treatment. The hemodialysis requires that the mother accompanies the child during sessions at least three times a week and, since it is not a healing practice, they also experience the waiting for a kidney transplant, attributing different meanings to this experience. To understand what it means for the mothers to accompany the child in a Pediatric Hemodialysis Unit and to construct a theoretical model representing this experience. The Symbolic Interactionism was adopted as a theoretical model and the Grounded Theory as a methodological framework. Data were collected through interviews with 11 mothers. The comparative analysis of the data enabled the identification of two phenomena that compose the experience: "Seeing the child´s life being sucked by the hemodialysis machine" expresses the experiences of the mothers that generates new demands to comprehend the new health conditions of their children and "Giving new meaning to the dependence of the hemodialysis machine" that represents the strategies employed to endure the experience. The relationship of these phenomena allowed the identification of the main category: "Having the mother's life imprisoned by the hemodialysis machine", from which we propose a new theoretical model. The results of the study allow us to provide a theoretical ground for planning an assistance that meets the real needs of the mothers, identifying aspects that require intervention.

  8. Liver enzymes in patients with chronic kidney disease undergoing peritoneal dialysis and hemodialysis

    Directory of Open Access Journals (Sweden)

    Isabella Ramos de Oliveira Liberato

    2012-01-01

    Full Text Available OBJECTIVE: The present study was designed to analyze the serum levels of aspartate and alanine aminotransferases, gamma-glutamyl transferase, and the hematocrit in patients with chronic kidney disease who were undergoing peritoneal dialysis or hemodialysis. PATIENTS AND METHODS: Twenty patients on peritoneal dialysis and 40 on hemodialysis were assessed, and the patients were matched according to the length of time that they had been on dialysis. Blood samples were collected (both before and after the session for those on hemodialysis to measure the enzymes and the hematocrit. RESULTS: In the samples from the patients who were undergoing peritoneal dialysis, the aspartate and alanine aminotransferase levels were slightly higher compared with the samples collected from the patients before the hemodialysis session and slightly lower compared with the samples collected after the hemodialysis session. The levels of gamma-glutamyl transferase in the hemodialysis patients were slightly higher than the levels in the patients who were undergoing peritoneal dialysis. In addition, the levels of aminotransferases and gamma-glutamyl transferase that were collected before the hemodialysis session were significantly lower than the values collected after the session. The hematocrit levels were significantly lower in the patients who were on peritoneal dialysis compared with the patients on hemodialysis (both before and after the hemodialysis session, and the levels were also significantly lower before hemodialysis compared with after hemodialysis. CONCLUSION: The aminotransferase levels in the patients who were undergoing peritoneal dialysis were slightly higher compared with the samples collected before the hemodialysis session, whereas the aminotransferase levels were slightly lower compared with the samples collected after the session. The hematocrits and the aminotransferase and gamma-glutamyl transferase levels of the samples collected after the

  9. The effect of foot massage on night sleep quality in hemodialysis patients

    Directory of Open Access Journals (Sweden)

    farhad Ariamanesh

    2015-05-01

    Full Text Available Background : Studies have shown, about 20 to 80 percent of hemodialysis patients have sleep problems that can lead to reduction of their quality of life. With regard to high number of hemodialysis patients in the present age, promoting the level of their health issues are deemed important. In this regared, the purpose of this research was to determine the effect of foot massage on night sleeping in hemodialysis patients. Materials and Methods: This experimental clinical trial design, was conducted on 80 hemodialysis patients, admitted to the hemodialysis wards of Shahid Rahimi and Shohada hospitals of Khorramabad city in 2014. Data gathering was done by Pittsburg questionnaire and Sleep Log, by which the sleep condition of the subjects was assessed before and after the night of massage therapy. The treatment was Stroke Foot Massage, carried out during dialysis for 10 minutes, three times a week, for four consecutive weeks. Results: Changes in the Pittsburg questionnaire score indicated that, using foot massage can improve sleep quality of hemodialysis patients and sleep hours increased and generally sleep condition was progressively improving each week than the week before (p<0/001. Conclusion: According to the results of this study, foot massage has a favorable impact on sleep quality in hemodialysis patients undergoing hemodialysis and can be applied and trained as a useful method to improve sleep quality of patients in hemodialysis wards.

  10. Blastocystis sp. and other intestinal parasites in hemodialysis patients.

    Science.gov (United States)

    Kulik, Rose Anne; Falavigna, Dina Lúcia Morais; Nishi, Letícia; Araujo, Silvana Marques

    2008-08-01

    Chronic renal insufficiency disease (CRI) leads to uremia in hemodialysis patients and induces a state of immunodepression that results in higher frequencies of infections and diarrhea. Hemodialysis patients resident in the city of Campo Mourão, Paraná, Brazil were analyzed from April 2006 through September 2007 for Blastocystis sp. and other intestinal parasites and for associated diarrhea. Fecal samples from 86 hemodialysis patients and 146 healthy (reference) persons were examined by standard methods for detecting ova, larvae and cysts, which included preservation in 10% formalin and the Kinyoun method. Thirty-three hemodialysis patients (45.1%) and 36 reference individuals (25.7%) were found to be parasitized. The differences in the percentages of parasitism and polyparasitism between the reference group and the chronic renal patients was significant (p= 0.0318 and 0.0019, respectively). Blastocystis sp. (18%-20.1%), Endolimax nana (14%-16.3%), Cryptosporidium sp. (4%-4.7%) and Entamoeba coli (4%-4.7%) were the most frequent protozoa found in the hemodialysis patients. Parasitism was not significantly associated with diarrhea (p=0.9947) or with decreased white blood cell counts (p=0.7046) in these individuals. Because parasitic infections may be an important comorbidity factor in hemodialysis patients, we suggest that parasitological stool examinations, especially for Blastocystis sp. and Cryptosporidium sp., be included in routine medical follow-up examinations of these patients.

  11. Blastocystis sp. and other intestinal parasites in hemodialysis patients

    Directory of Open Access Journals (Sweden)

    Rose Anne Kulik

    Full Text Available Chronic renal insufficiency disease (CRI leads to uremia in hemodialysis patients and induces a state of immunodepression that results in higher frequencies of infections and diarrhea. Hemodialysis patients resident in the city of Campo Mourão, Paraná, Brazil were analyzed from April 2006 through September 2007 for Blastocystis sp. and other intestinal parasites and for associated diarrhea. Fecal samples from 86 hemodialysis patients and 146 healthy (reference persons were examined by standard methods for detecting ova, larvae and cysts, which included preservation in 10% formalin and the Kinyoun method. Thirty-three hemodialysis patients (45.1% and 36 reference individuals (25.7% were found to be parasitized. The differences in the percentages of parasitism and polyparasitism between the reference group and the chronic renal patients was significant (p= 0.0318 and 0.0019, respectively. Blastocystis sp. (18%-20.1%, Endolimax nana (14%-16.3%, Cryptosporidium sp. (4%-4.7% and Entamoeba coli (4%-4.7% were the most frequent protozoa found in the hemodialysis patients. Parasitism was not significantly associated with diarrhea (p=0.9947 or with decreased white blood cell counts (p=0.7046 in these individuals. Because parasitic infections may be an important comorbidity factor in hemodialysis patients, we suggest that parasitological stool examinations, especially for Blastocystis sp. and Cryptosporidium sp., be included in routine medical follow-up examinations of these patients.

  12. Sleep quality and spiritual well-being in hemodialysis patients.

    Science.gov (United States)

    Eslami, Ahmad Ali; Rabiei, Leili; Khayri, Freidoon; Rashidi Nooshabadi, Mohammad Reza; Masoudi, Reza

    2014-07-01

    Sleep disorders are considered as one of the most important problems in hemodialysis patients, making their everyday life a serious hazard. Sleep quality of hemodialysis patients and consequences of sleep disorders on other aspects of health such as spiritual well-being are important issues. This study examined the relationship between spiritual well-being and quality of sleep in hemodialysis patients in Isfahan, Iran. This study was a correlation research, carried out on 190 hemodialysis patients. Data collection Questionnaires included demographic forms, Pittsburgh sleep quality index (PSQI), and Ellison and Paloutzian spiritual well-being scale. Data were analyzed using descriptive and inferential statistics (Pearson correlation and linear regression analysis) at P spiritual health conditions. Pearson correlation test showed significant relationship between the sleep quality items of Pittsburg and spiritual well-being (P spiritual health, family, education, financial status, marital status, occupation, and use of sleep medication, the predictive power of these variables was found 0.417% and prediction of spiritual well-being was more than others (ß = 0.209). Considering bed as one of the most vital physical, mental, and emotional needs, it is very important in mental and spiritual well-being of hemodialysis patients as an influencing factor in mental relaxation and reducing disease tensions. Paying attention to sleep quality and spiritual well-being components of hemodialysis patients in formulating and promoting healthcare programs is recommended.

  13. Endovascular treatment of central venous stenosis and obstruction in hemodialysis patients.

    Science.gov (United States)

    Shi, Ya-xue; Ye, Meng; Liang, Wei; Zhang, Hao; Zhao, Yi-ping; Zhang, Ji-wei

    2013-02-01

    Central venous stenosis and obstruction (CVD) is a serious and prevalent challenge to both resolve the venous hypertension symptoms and maintain the pantency of the ipsilateral hemodialysis access in hemodialysis patients. This study aimed to summarize our experience of the endovascular management of the central venous stenosis or obstruction in hemodialysis patients. Twenty-four haemodialysis cases of central vein stenosis or obstruction with ipsilateral functional vascular access in our hospital between July 2006 and February 2012 were treated by interventional therapy and the data were analyzed retrospectively. Eighteen males and six females with mean age of (66.4 ± 13.8) years and manifesting with arm swelling and venous hypertension were enrolled; 62.5% of them had a history of catheterization. Venography showed stenotic lesion in 10 cases including eight cases of brachiocephalic vein stenosis and two cases of subclavian vein stenosis and 14 cases of obstruction lesions including seven cases of short brachiocephalic obstruction and seven cases of long segment obstruction. Interventional therapy was performed and the technique success rate was 83.3%. Percutaneous transluminal angioplasty (PTA) was performed in nine cases and stent was performed in 11 cases firstly. The symptoms of venous hypertension were resolved after intervention in all the cases. There was no major complication and death perioperatively. During follow-up, reintervention was done, the primary patency rates were (88.9 ± 10.5)%, (64.8 ± 10.5)% and (48.6 ± 18.7)% at 3 months, 6 months and 1 year after treatment in the PTA group; (90.0 ± 9.5)% and (77.1 ± 14.4)% at 6 months and 1 year after treatment in the stent group, respectively. The secondary patency rates were (48.6 ± 18.7)% in the PTA group and (83.3 ± 15.2)% in the stent group 1 year after treatment, respectively. There was no significant difference between the two groups (primary patency, P = 0.20; secondary patency, P = 0

  14. Skin Perfusion Pressure Is a Prognostic Factor in Hemodialysis Patients

    Directory of Open Access Journals (Sweden)

    Shingo Hatakeyama

    2012-01-01

    Full Text Available Peripheral arterial disease (PAD is common in hemodialysis patients and predicts a poor prognosis. We conducted a prospective cohort study to identify risk factors for PAD including skin perfusion pressure (SPP in hemodialysis patients. The cohort included 373 hemodialysis patients among 548 patients who received hemodialysis at Oyokyo Kidney Research Institute, Hirosaki, Japan from August 2008 to December 2010. The endpoints were lower limb survival (peripheral angioplasty or amputation events and overall survival of 2 years. Our results showed that <70 mmHg SPP was a poor prognosis for the lower limb survival and overall survival. We also identified age, history of cardiovascular disease, presence of diabetes mellitus, smoking history, and SPP < 70 mmHg as independent risk factors for lower limb survival and overall survival. Then, we constructed risk criteria using the significantly independent risk factors. We can clearly stratify lower limb survival and overall survival of the hemodialysis patients into 3 groups. Although the observation period is short, we conclude that SPP value has the potential to be a risk factor that predicts both lower limb survival and the prognosis of hemodialysis patients.

  15. Emergency coronary angioplasty with stenting using Cordis® diagnostic coronary catheters when there is difficulty in engaging guide catheters and bench evaluation of diagnostic and guide catheters.

    Science.gov (United States)

    Arokiaraj, Mark Christopher

    2018-02-01

    Difficulty in engaging with guide catheters is not uncommon in acute emergencies. We aimed to evaluate the use of Cordis ® INFINITI diagnostic catheters to perform angioplasty in patients in whom the coronaries cannot be engaged using standard guide catheters. In 34 cases of acute coronary syndrome, when difficulty in engagement with two standard guide catheters was encountered with reasonable manipulations, angioplasty was performed using diagnostic catheters. In total, 40 stents were placed by this technique. Pushability and trackability, distal tip flexion and three-point bending tests were performed to evaluate the performance of the guide and diagnostic catheters. Angioplasty was performed easily in a setting where it would have been very difficult to perform. Coronary dissection occurred in one patient, treated by a stent. The stent and dilatation balloons were easily passed through the diagnostic catheters. Pressure tracings were clearly preserved with certain stent delivery systems, and at angioplasty, although there was slightly reduced opacification of the respective artery, the coronary anatomy was sufficiently visualized to perform angioplasty. No periprocedural target lesion complications were seen in any cases. Pushability and trackability tests showed good force transmission along a tortuous path with diagnostic catheters, and balanced force-displacement curves from three-point bending tests and distal tip softness tests. Angioplasty with stenting can be performed safely through 6F Cordis ® infiniti diagnostic catheters when difficulty in engaging guide catheters is encountered. Copyright © 2018 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  16. The effect of hemodialysis on balance measurements and risk of fall.

    Science.gov (United States)

    Erken, Ertugrul; Ozelsancak, Ruya; Sahin, Safak; Yılmaz, Emine Ece; Torun, Dilek; Leblebici, Berrin; Kuyucu, Yunus Emre; Sezer, Siren

    2016-10-01

    Patients with end-stage renal disease (ESRD) have increased risk of falls and fall-related complications. Other than aging and factors related to chronic kidney disease, treatment of hemodialysis may also contribute to this increased risk. The aim of this study was to demonstrate the impairment of balance after a session of hemodialysis with a quantitative assessment and reveal an increased fall risk that would possibly be related to treatment of hemodialysis for patients on maintenance hemodialysis. Fifty-six patients with ESRD on chronic hemodialysis program and 53 healthy individuals were involved in this study. Fall Index percentages were calculated, and fall risk categories were determined for all patients and healthy controls using Tetrax posturography device (Sunlight Medical Ltd Israel). The patient group was evaluated twice for balance, before and after a routine session of hemodialysis. Fall Index scores of healthy controls were lower than that of ESRD patients (p = 0.001). In the patient group, we found the mean Fall Index to be significantly higher at the post-dialysis assessment compared to the pre-dialysis assessment (p = 0.003). The number of patients with high risk of falling also increased at the post-dialysis assessment yet the difference did not reach significance. Fall Index was correlated with the increase in age only at the pre-dialysis balance measurement (p = 0.038). Patients with better dialysis adequacy had significantly lower Fall Index scores than the others at the pre-dialysis balance measurement (p = 0.004). The difference was not significant at the post-dialysis measurement. In the current study, we evaluated the balance of ESRD patients before and after a routine session of hemodialysis treatment. This is the first study to investigate the effect of hemodialysis on balance, using an electronic posturographic balance system. We found the Fall Index score to be significantly higher after hemodialysis, indicating a negative

  17. Percutaneous pigtail catheter in the treatment of pneumothorax in major burns: the best alternative? Case report and review of literature.

    Science.gov (United States)

    Sebastian, Raul; Ghanem, Omar; Diroma, Frank; Milner, Stephen M; Gerold, Kevin B; Price, Leigh A

    2015-05-01

    Multiple factors place burn patients at a high risk of pneumothorax development. Currently, no specific recommendations for the management of pneumothorax in large total body surface area (TBSA) burn patients exist. We present a case of a major burn patient who developed pneumothorax after central line insertion. After the traditional large bore (24 Fr) chest tube failed to resolve the pneumothorax, the pneumothorax was ultimately managed by a percutaneous placed pigtail catheter thoracostomy placement and resulted in its complete resolution. We will review the current recommendations of pneumothorax treatment and will highlight on the use of pigtail catheters in pneumothorax management in burn patients. Copyright © 2014 Elsevier Ltd and ISBI. All rights reserved.

  18. Efficacy and safety of rotating pigtail catheter: lower extremity deep vein thrombosis of may-thurner syndrome

    International Nuclear Information System (INIS)

    Kim, Yoon Kyung; Kang, Byung Chul; Gang, Sung Gown

    2004-01-01

    The purpose of this study was to evaluate the efficacy and safety of mechanical fragmentation of iliofemoral deep vein thromboses (DVTs) with a rotating pigtail catheter followed by aspiration thrombectomy. Ten patients (eight females, two males, 56.8 +/- 21.37 years) with iliofemoral DVT underwent treatment for a total of ten affected limbs. Approximately 5-10 min after infusing 400,000-700,000 IU urokinase (UK) into the thrombosed deep veins, the thromboses were fragmented by the mechanical action of the rotating pigtail catheter tip. Following their fragmentation, the fragmented thromboses were aspirated. After completion of the above procedure, a stent was inserted if iliac vein stenosis was demonstrated. We evaluated the total procedure time, volume of thrombolytic agent (urokinase), valvular injury, symptom-free time interval and success rate (primary patency rate). In all 10 patients, the iliofemoral deep vein thrombosis was successfully fragmented and aspirated using the combination method of a rotating pigtail catheter and aspiration thrombectomy (clinical and technical success rate, 100%). The thromboses were declotted by means of a rotating pigtail catheter with an average treatment time of 5.7 minutes. The average duration of the total intervention was 108 min. The mean primary patency was approximately 4 months with no recurrence. The total UK dose was 890,000 IU on average. There were no major complications, such as pulmonary embolism or cerebral hemorrhage, while performing the thrombus-fragmentation procedure using the rotating pigtail catheter. The combination method of a rotating pigtail catheter and aspiration thrombectomy for the treatment of iliofemoral deep vein thrombosis was found to be rapid, safe and effective for accomplishing recanalization in all cases without complication. Therefore, this procedure constitutes a potential treatment option in patients presenting with iliofemoral vein thrombosis

  19. The Language of Coping: Understanding Filipino Geriatric Patients' Hemodialysis Lived Experiences

    Science.gov (United States)

    de Guzman, Allan B.; Chy, Mark Anthony S.; Concepcion, April Faye P.; Conferido, Alvin John C.; Coretico, Kristine I.

    2009-01-01

    The majority of patients with chronic kidney disease (CKD) are undergoing maintenance hemodialysis. Hemodialysis is a process of removing metabolic waste, other poisons, and excess fluids from the blood and replacing essential blood constituents through a dialysis machine. With hemodialysis causing stress not only to physical status but also to…

  20. Hemodialysis Reliable Outflow (HeRO) device in end-stage dialysis access: a decision analysis model.

    Science.gov (United States)

    Dageforde, Leigh Anne; Bream, Peter R; Moore, Derek E

    2012-09-01

    The Hemodialysis Reliable Outflow (HeRO) dialysis access device is a permanent tunneled dialysis graft connected to a central venous catheter and is used in patients with end-stage dialysis access (ESDA) issues secondary to central venous stenosis. The safety and effectiveness of the HeRO device has previously been proven, but no study thus far has compared the cost of its use with tunneled dialysis catheters (TDCs) and thigh grafts in patients with ESDA. A decision analytic model was developed to simulate outcomes for patients with ESDA undergoing placement of a HeRO dialysis access device, TDC, or thigh graft. Outcomes of interest were infection, thrombosis, and ischemic events. Baseline values, ranges, and costs were determined from a systematic review of the literature. Total costs were based on 1 year of post-procedure outcomes. Sensitivity analyses were conducted to test model strength. The HeRO dialysis access device is the least costly dialysis access with an average 1-year cost of $6521. The 1-year cost for a TDC was $8477. A thigh graft accounted for $9567 in a 1-year time period. The HeRO dialysis access device is the least costly method of ESDA. The primary determinants of cost in this model are infection in TDCs and leg ischemia necessitating amputation in thigh grafts. Further study is necessary to incorporate patient preference and quality of life into the model. Copyright © 2012 Elsevier Inc. All rights reserved.