WorldWideScience

Sample records for helium-jet coupled on-line

  1. Advances in the helium-jet coupled on-line mass seperator RAMA

    International Nuclear Information System (INIS)

    Moltz, D.M.; Aeystoe, J.; Cable, M.D.; Parry, R.F.; Haustein, P.E.; Wouters, J.M.; Cerny, J.; California Univ., Berkeley

    1981-01-01

    General improvements to the on-line mass separator RAMA have yielded a greater reliability and efficiency for some elements. A new utilitarian helium-jet chamber has been installed to facilitate quick target and degrader foil changes in addition to a new ion source holder. A higher efficiency hollow-cathode, cathode-extraction ion source for lower melting point elements ( 0 C) has also been designed. Tests with the beta-delayed proton emitter 37 Ca showed a factor of five increase in yield over the old hollow-cathode, anode-extraction source. A differentially-pumped tape drive system compatible with both γ-γ and β-γ experiments has been incorporated into the general detection system. All major operating parameters will soon be monitored by a complete stand-alone microprocessor system which will eventually be upgraded to a closed-loop control system. (orig.)

  2. Advances in the helium-jet coupled on-line mass separator RAMA

    International Nuclear Information System (INIS)

    Moltz, D.M.; Aysto, J.; Cable, M.D.; Parry, R.F.; Haustein, P.E.; Wouters, J.M.; Cerny, J.

    1980-01-01

    General improvements to the on-line mass separator RAMA (Recoil Atom Mass Analyzer) have yielded a greater reliability and efficiency for some elements. A new utilitarian helium-jet chamber has been installed to facilitate quick target and degrader foil changes in addition to a new ion source holder. A higher efficiency hollow-cathode, cathode-extraction ion source, for lower melting point elements ( 0 C) has also been designed. Tests with the beta-delayed proton emitter 37 Ca showed a factor of five increase in yield over the old hollow-cathode, anode-extraction source. A differentially-pumped-tape drive system compatible with both γ-γ and β-γ experiments has been incorporated into the general detection system. All major operating parameters will soon be monitored by a complete stand-alone microprocessor system which will eventually be upgraded to a closed-loop control system

  3. Identification of new proton-rich rare earth nuclei by means of the coupled system helium jet-isotope separator of SARA

    International Nuclear Information System (INIS)

    Ollivier, T.

    1986-01-01

    In order to study new exotic nuclei far from stability we built a fast separation system by coupling a helium jet with the medium-current source of the mass separator. First the tests were made in Lyon and then the system used on line with the heavy ion accelerator SARA, in Grenoble. We obtained efficiency greater than 1% for each element and a better chemical independence. This allowed us to perform experiments on rare-earth region near N=82, with fusion-evaporation reactions after an investigation of various ranges of beam energies. The first results allow to identify two new isotopes, 143 Tb (12s) and 138 Eu (12s). The decay schemes obtained are analysed in the frame of existing models [fr

  4. Efficiency of an on-line isotope separator system employing cooled and NaCl-loaded He-jet methods

    International Nuclear Information System (INIS)

    Aeystoe, J.; Rantala, V.; Valli, K.; Hillebrand, S.; Kortelahti, M.; Eskola, K.; Raunemaa, T.

    1976-01-01

    A pure helium-jet at liquid nitrogen temperature coupled to a Nielsen type ion source, and a NaCl-loaded helium-jet coupled to a hollow-cathode ion source have been investigated as means to connect a cyclotron target chamber on-line to a mass separator. Technical details and performances of some critical parts of the system are described. Total separation efficiencies measured under various experimental conditions for several nuclides vary between 0.01 and 1.0%. (Auth.)

  5. The Chalk River helium jet and skimmer system

    International Nuclear Information System (INIS)

    Schmeing, H.; Koslowsky, V.; Wightman, M.; Hardy, J.C.; MacDonald, J.A.; Faestermann, T.; Andrews, H.R.; Geiger, J.S.; Graham, R.L.

    1976-01-01

    A helium jet and skimmer system intended as an interface between a target location at the Chalk River tandem accelerator and the ion source of an on-line separator presently under construction has been developed. The system consists of a target chamber, a 125 cm long capillary, and a one stage skimmer chamber. The designs of the target and skimmer chambers allow one to vary a large number of independent flow and geometrical parameters with accurate reproducibility. Experiments with the β-delayed proton emitter 25 Si (tsub(1/2)=218 ms) produced in the reaction 24 Mg( 3 He,2n) 25 Si show that under optimized conditions about 75% of the reaction products leaving the target are transported to the skimmer. Of those, more than 90% pass through the skimmer orifice, which separates off 97.5% of the transport gas, helium. By introducing an additional helium flow across the skimming orifice the amount of helium separated off the transport jet can be increased to beyond 99.85%, leaving the high throughput of recoils unaffected. (Auth.)

  6. Transportation system of recoil nucleus by helium jet

    International Nuclear Information System (INIS)

    Cabral, S.C.; Borges, A.M.; Lemos Junior, O.F.; Auler, L.T.; Silva, A.G. da

    1981-01-01

    The transportation system of recoil nucleus by helium jet, is studied. It is used a technique aiming to put in the detection area (region of low background) the recoils, produced by nuclear reactions between target and particle beams, those produced with the help of cyclotron CV-28. (E.G.) [pt

  7. Approaches for on-line coupling of extraction and chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Hyoetylaeinen, Tuulia; Riekkola, Marja-Liisa [Laboratory of Analytical Chemistry, Department of Chemistry, University of Helsinki, P.O. Box 55, 00014, Helsinki (Finland)

    2004-04-01

    This review provides an overview of the approaches available in order to perform on-line coupling of various extraction techniques with liquid and gas chromatography, for the analysis of semivolatile and nonvolatile analytes in liquid and solid samples. The main focus is on the instrumental set-up of these techniques. Selected real applications are described by way of illustration. The extraction methods suitable for on-line coupling covered in this review are: liquid-liquid extraction, solid-phase extraction, membrane-based techniques, pressurised liquid extraction, supercritical fluid extraction, and microwave- and sonication-assisted extractions. The following systems are not covered in this review: on-line coupled solid-phase extraction-liquid chromatography, purge-and-trap-GC, and membrane extraction with a sorbent interface-GC. (orig.)

  8. Initial results with the Berkeley on-line mass separator-RAMA

    International Nuclear Information System (INIS)

    Cerny, J.; Moltz, D.M.; Evans, H.C.; Vieira, D.J.; Parry, R.F.; Wouters, J.M.; Gough, R.A.; Zisman, M.S.

    1977-11-01

    Initial performance is described for a reasonably fast and universal (having little or no chemical selectivity) on-line mass analysis system used to expand capabilities in studying nuclei far from stability. The system is termed RAMA, an acronym for Recoil Atom Mass Analyzer. Basically, this system utilizes the helium-jet method to transport activity to a Sidenius hollow-cathode ion source which is coupled to a mass spectrometer. Initial experiments and planned improvements are discussed. Transport efficiencies of between 10 and 60 percent have routinely been achieved, though the latter is much more typical when conditions are optimized

  9. Development of an ion guide coupled to an on-line isotope separation system on Sara. Identification and study of isospin exotic nuclei at Isolde and Sara

    International Nuclear Information System (INIS)

    Bouldjedri, A.

    1992-06-01

    This work is concerned with the study of exotic nuclei located on both sides of the stability-line and known as neutron rich and neutron deficient respectively. For the former, produced by alpha particle-induced fission, an on-line isotope separation with an ion guide (IGISOL) has been developed and submitted to several off-line and on-line optimization tests showing capacity to spectroscopic studies. In the case of neutron deficient nuclei near the magicity Z=82, 182 Tl(3s) has been identified and its decaying modes and those of 183 Tl ground state, studied, using the on-line separator ISOLDE. On the other hand, the β decay of 172,175 Ir produced in 32 S induced reaction is studied using a helium jet system on the SARA accelerator. Existence of isomers is derived from half-lives measurements

  10. Capillary electrophoresis microchip coupled with on-line chemiluminescence detection

    International Nuclear Information System (INIS)

    Su Rongguo; Lin Jinming; Qu Feng; Chen Zhifeng; Gao Yunhua; Yamada, Masaaki

    2004-01-01

    In the present work, chemiluminescence detection was integrated with capillary electrophoresis microchip. The microchip was designed on the principle of flow-injection chemiluminescence system and capillary electrophoresis. It has three main channels, five reservoirs and a detection cell. As model samples, dopamine and catechol were separated and detected using a permanganate chemiluminescent system on the prepared microchip. The samples were electrokinetically injected into the double-T cross section, separated in the separation channel, and then oxidized by chemiluminescent reagent delivered by a home-made micropump to produce light in the detection cell. The electroosmotic flow could be smoothly coupled with the micropump flow. The detection limits for dopamine and catechol were 20.0 and 10.0 μM, respectively. Successful separation and detection of dopamine and catechol demonstrated the distinct advantages of integration of chemiluminescent detection on a microchip for rapid and sensitive analysis

  11. Automation of the helium jet transport system for nuclear recoil products

    International Nuclear Information System (INIS)

    Bellido, Luis F.; Pedrosa, Paulo S.

    1996-09-01

    A computer code and an interface hardware to automate the acquisition data and the sample changer in a helium jet transport system of recoil nucleus was developed for an IBM or compatible personal microcomputer. The software works with a Spectrum-ACE/ADCAM ORTEC's multichannel analysers and the interface card uses the 03EFh port to command the sample changer. This system allows to measure, by gamma spectrometry, radionuclides with half-lives of order of seconds produced from nuclear reactions. (author)

  12. Study of the /sup 233/Th(. gamma. ,xn)226,222/supTh/ reaction at. gamma. -energies <= 60 MeV using a helium jet

    Energy Technology Data Exchange (ETDEWEB)

    Jungclas, H

    1974-01-01

    A helium jet system is set up for the transport and investigation of daughter products of the nuclear reaction /sup 232/Th (..gamma..,xn) at E/sub..gamma../<=60 MeV. The theoretical fundamentals for the target kinematics such as photoexcitation, evaporation cascade and range of heavy ions are presented. Activation experiments with thick thorium tetrafluoride targets and catcher foils for the reaction products emitted showed a nuclide-dependent forwards-backwards ratio which agrees with the calculated values within 1-2 standard deviations of the statistic error. A target system with thorium nitrate coated glass wool is tested with the helium in 'on-line' operation and after irradiation is used for the investigation of the long-lived activities with the excess pressure jet. The radioactive decay series of the transported reaction products are identified by alpha spectroscopy.

  13. Supercritical fluid extraction-capillary gas chromatography: on-line coupling with a programmed temperature vaporizer

    NARCIS (Netherlands)

    Houben, R.J.; Janssen, J.G.M.; Leclercq, P.A.; Rijks, J.A.; Cramers, C.A.M.G.

    1990-01-01

    A simple and versatile system is described for the on-line coupling of SFE to capillary GC. The interfacing consists of a programmed temperature vaporizer (PTV) injector. With this injector it is possible to combine solute trapping, elimination of a high flow of extraction fluid, and quantitative

  14. Numerical modeling and validation of helium jet impingement cooling of high heat flux divertor components

    International Nuclear Information System (INIS)

    Koncar, Bostjan; Simonovski, Igor; Norajitra, Prachai

    2009-01-01

    Numerical analyses of jet impingement cooling presented in this paper were performed as a part of helium-cooled divertor studies for post-ITER generation of fusion reactors. The cooling ability of divertor cooled by multiple helium jets was analysed. Thermal-hydraulic characteristics and temperature distributions in the solid structures were predicted for the reference geometry of one cooling finger. To assess numerical errors, different meshes (hexagonal, tetra, tetra-prism) and discretisation schemes were used. The temperatures in the solid structures decrease with finer mesh and higher order discretisation and converge towards finite values. Numerical simulations were validated against high heat flux experiments, performed at Efremov Institute, St. Petersburg. The predicted design parameters show reasonable agreement with measured data. The calculated maximum thimble temperature was below the tile-thimble brazing temperature, indicating good heat removal capability of reference divertor design. (author)

  15. The 1-way on-line coupled atmospheric chemistry model system MECO(n – Part 2: On-line coupling with the Multi-Model-Driver (MMD

    Directory of Open Access Journals (Sweden)

    A. Kerkweg

    2012-01-01

    Full Text Available A new, highly flexible model system for the seamless dynamical down-scaling of meteorological and chemical processes from the global to the meso-γ scale is presented. A global model and a cascade of an arbitrary number of limited-area model instances run concurrently in the same parallel environment, in which the coarser grained instances provide the boundary data for the finer grained instances. Thus, disk-space intensive and time consuming intermediate and pre-processing steps are entirely avoided and the time interpolation errors of common off-line nesting approaches are minimised. More specifically, the regional model COSMO of the German Weather Service (DWD is nested on-line into the atmospheric general circulation model ECHAM5 within the Modular Earth Submodel System (MESSy framework. ECHAM5 and COSMO have previously been equipped with the MESSy infrastructure, implying that the same process formulations (MESSy submodels are available for both models. This guarantees the highest degree of achievable consistency, between both, the meteorological and chemical conditions at the domain boundaries of the nested limited-area model, and between the process formulations on all scales.

    The on-line nesting of the different models is established by a client-server approach with the newly developed Multi-Model-Driver (MMD, an additional component of the MESSy infrastructure. With MMD an arbitrary number of model instances can be run concurrently within the same message passing interface (MPI environment, the respective coarser model (either global or regional is the server for the nested finer (regional client model, i.e. it provides the data required to calculate the initial and boundary fields to the client model. On-line nesting means that the coupled (client-server models exchange their data via the computer memory, in contrast to the data exchange via files on disk in common off-line nesting approaches. MMD consists of a library

  16. Characterisation of spent nuclear fuels by an on-line coupled HPLC-ICP-MS system

    International Nuclear Information System (INIS)

    Guenther-Leopold, I.; Gabler, F.; Wernli, B.; Kopajtic, Z.

    2000-01-01

    The determination of burn-up is one of the essential components of post-irradiation examination of nuclear fuel samples. In the framework of the ARIANE programme (Actinides Research in a Nuclear Element), at PSI the analysis of the isotopic vectors of uranium, plutonium, neodymium and some other fission and spallation products was carried out for the first time in the Hot Lab using high-performance liquid chromatography (HPLC), coupled on-line with an inductively coupled plasma mass spectrometer (ICP-MS). The results of these investigations, a comparison with the classical technique for burn-up determination, the advantages and limitations of the new method, the accuracy and precision of these types of analyses, the applicability of the technique to other samples and separation problems, and conclusions for further analyses of nuclear fuel samples, are here presented. (authors)

  17. On-line coupled LC-LC-GC for irradiation detection in complex lipid matrices

    International Nuclear Information System (INIS)

    Schulzki, G.; Spiegelberg, A.; Helle, N.; Boegl, K.W.; Schreiber, G.A.

    1993-01-01

    Since sample preparation with HPLC coupled on-line to the GC has been performed for only a few weeks in our laboratory, the results presented give a first look at what can be done by means of this technique. Even difficult samples as the described fish species, where an unequivocal identification regarding an irradiation treatment seemed to become a hopeless enterprise, could be managed. Because of the greater variety of fatty acids in fish ''new'' radiation-induced hydrocarbons were available. According to the theory of Nawar in addition to 16:2 and 17:2 hydrocarbons we have looked for in irradiated meat, further alkadienes appeared in irradiated fish, which were 14:2, 18:2 and 20:2. Analysis of the alkadiene-fraction, transferred to the GC after a two step LC clean up, resulted in an unequivocal identification of all fish samples as well as the fruits and sponge cake. For fruits and sponge cake the detection limit seems to be clearly below 0.5 kGy. It can further be lowered by increasing the amount of lipid whereas the upper limit for a certain LC column has to be determined. In contrast to these samples only qualitative results were obtained for fish. In the case of sponge cake for the first time irradiation of a component of a heat treated food was detected. Further investigations regarding reproducibility, dose dependence and detection limit have to be done. On-line coupled (LC-)LC-GC was proved to be a highly efficient method for analysis of complex samples. In contrast to off-line Florisil column chromatography only a small part of the initial lipid material is needed because the complete hydrocarbon fraction is transferred on-line to the GC. This offers the possibility to analyze even foods with a low fat content like various seafoods. Classification of the hydrocarbon fraction by a two step LC may facilitate the identification of the radiolytic products also if no mass spectrometric detection system is available. (orig./vhe)

  18. Operational on-line coupled chemical weather forecasts for Europe with WRF/Chem

    Science.gov (United States)

    Hirtl, Marcus; Mantovani, Simone; Krüger, Bernd C.; Flandorfer, Claudia; Langer, Matthias

    2014-05-01

    Air quality is a key element for the well-being and quality of life of European citizens. Air pollution measurements and modeling tools are essential for the assessment of air quality according to EU legislation. The responsibilities of ZAMG as the national weather service of Austria include the support of the federal states and the public in questions connected to the protection of the environment in the frame of advisory and counseling services as well as expert opinions. ZAMG conducts daily Air-Quality forecasts using the on-line coupled model WRF/Chem. Meteorology is simulated simultaneously with the emissions, turbulent mixing, transport, transformation, and fate of trace gases and aerosols. The emphasis of the application is on predicting pollutants over Austria. Two domains are used for the simulations: the mother domain covers Europe with a resolution of 12 km, the inner domain includes the alpine region with a horizontal resolution of 4 km; 45 model levels are used in the vertical direction. The model runs 2 times per day for a period of 72 hours and is initialized with ECMWF forecasts. On-line coupled models allow considering two-way interactions between different atmospheric processes including chemistry (both gases and aerosols), clouds, radiation, boundary layer, emissions, meteorology and climate. In the operational set-up direct-, indirect and semi-direct effects between meteorology and air chemistry are enabled. The model is running on the HPCF (High Performance Computing Facility) of the ZAMG. In the current set-up 1248 CPUs are used. As the simulations need a big amount of computing resources, a method to safe I/O-time was implemented. Every MPI task writes all its output into the shared memory filesystem of the compute nodes. Once the WRF/Chem integration is finished, all split NetCDF-files are merged and saved on the global file system. The merge-routine is based on parallel-NetCDF. With this method the model runs about 30% faster on the SGI

  19. Coupling sequential injection on-line preconcentration using a PTFE beads packed column to direct injection nebulization inductively coupled plasma mass spectrometry

    DEFF Research Database (Denmark)

    Wang, Jianhua; Hansen, Elo Harald

    2002-01-01

    An automated sequential injection on-line preconcentration procedure for trace metals by using a PTFE bead-packed microcolumn coupled to ICP-MS is described, and used for simultaneous analyses of cadmium and lead. In dilute nitric acid (0.5%, v/v), neutral complexes between the analytes...

  20. Optical fiber-spectrophotometer coupling: when will the measurement be on line

    International Nuclear Information System (INIS)

    Anon.

    1984-01-01

    Ten years of research and development made at CEA in colorimetry and remote spectrometry by optical fibers allow to define more precisely the best conditions for on-line measurement in industrial process controls and in laboratory analysis in adverse environment. This article presents the new possibilities brought by this type of measurement. One of them is the simultaneous determination of many components; current studies concern the control ''in situ'' of uranium (IV) and (VI) and plutonium (III) and (IV) mixtures [fr

  1. An on-line dilution system for spectrometry using an inductively coupled plasma source

    International Nuclear Information System (INIS)

    Moore, G.L.; Watson, A.E.; Humphries-Cuff, P.J.

    1982-01-01

    An on-line dilution system that uses a two-channel peristaltic pump to feed a GMK Babington type of nebulizer is described. By the use of a diluent containing the appropriate concentrations of acid, sodium, and internal standard element, which was fed at a constant rate to the nebulizer, the system produced analytical results that are not significantly different (less than 3 per cent relative) from those obtained with the normal dilution technique. However, a considerable saving in time is achieved, as well as a saving in the use of expensive reagents

  2. Wireless Power Supply via Coupled Magnetic Resonance for on-line Monitoring Wireless Sensor of High-voltage Electrical Equipment

    DEFF Research Database (Denmark)

    Xingkui, Mao; Qisheng, Huang; Yudi, Xiao

    2016-01-01

    On-line monitoring of high-voltage electrical equipment (HV-EE) aiming to detect faults effectively has become crucial to avoid serious accidents. Moreover, highly reliable power supplies are the key component for the wireless sensors equipped in such on-line monitoring systems. Therefore......, in this paper, the wireless power supply via coupled magnetic resonance (MR-WPS) is proposed for powering the wireless sensor and the associated wireless sensor solution is also proposed. The key specifications of the MR-WPS working in switchgear cabinet with a harsh operation environment are analyzed...... power is able to be delivered to the wireless sensor through the designed MR-WPS, and therefore the theoretical analysis and design is verified....

  3. Basic studies of a gas-jet-coupled ion source for on-line isotope separation

    International Nuclear Information System (INIS)

    Anderl, R.A.; Novick, V.J.; Greenwood, R.C.

    1980-01-01

    A hollow-cathode ion source was used in a gas-jet-coupled configuration to produce ion beams of fission products transported to it from a 252 Cf fission source. Solid aerosols of NaCl and Ag were used effectively as activity carriers in the gas-jet system. Flat-plate skimmers provided an effective coupling of the ion source to the gas jet. Ge(Li) spectrometric measurements of the activity deposited on an ion-beam collector relative to that deposited on a pre-skimmer collector were used to obtain separation efficiencies ranging from 0.1% to > 1% for Sr, Y, Tc, Te, Cs, Ba, Ce, Pr, Nd and Sm. The use of CCl 4 as a support gas resulted in a significant enhancement of the alkaline-earth and rare-earth separation efficiencies

  4. Actinides analysis in emergency situation by on-line coupling between a calix[6]arene-based chromatography column and an Inductively Coupled Plasma-Mass Spectrometer

    International Nuclear Information System (INIS)

    Baghdadi, Sarah

    2015-01-01

    In the event of a nuclear crisis, involving actinides (U, Pu, Am) it is important to have fast analysis methods available in order to identify people that could be contaminated. Usually, they are performed in urine or faeces. Even though, analytical methods used with alpha detection are reliable they are lengthy and tedious to set up. This work consisted in developing an on-line coupling method between a calix[6]arene-based chromatography column and an inductively coupled plasma mass spectrometer (ICP-MS). To do so, a speciation study of actinides in mineralised urine was developed to understand the chemical equilibria happening during the actinides extraction. A protocol was elaborated to extract simultaneously all three actinides at pH = 5, then co-elute them with 0.25 mol.L -1 H 3 PO 4 . Recovery was 56 %, 74 % and 85 % for U, Pu and Am respectively. The column was then coupled to the ICP-MS. A parameter study helped defining mineralisation duration, extraction and elution flow-rates. It was then possible to propose an on-line coupling system allowing reaching detection limits lower than 0.5 mBq.L-1 for 238 U and 243 Am and lower than 5 mBq.L -1 for 239 Pu and 241 Am, for analysis duration lower than 6 hours. These analytical performances show the interest of this technique for a use in a nuclear crisis situation. (author)

  5. Determination of major aromatic constituents in vanilla using an on-line supercritical fluid extraction coupled with supercritical fluid chromatography.

    Science.gov (United States)

    Liang, Yanshan; Liu, Jiaqi; Zhong, Qisheng; Shen, Lingling; Yao, Jinting; Huang, Taohong; Zhou, Ting

    2018-04-01

    An on-line supercritical fluid extraction coupled with supercritical fluid chromatography method was developed for the determination of four major aromatic constituents in vanilla. The parameters of supercritical fluid extraction were systematically investigated using single factor optimization experiments and response surface methodology by a Box-Behnken design. The modifier ratio, split ratio, and the extraction temperature and pressure were the major parameters which have significant effects on the extraction. While the static extraction time, dynamic extraction time, and recycle time had little influence on the compounds with low polarity. Under the optimized conditions, the relative extraction efficiencies of all the constituents reached 89.0-95.1%. The limits of quantification were in the range of 1.123-4.747 μg. The limits of detection were in the range of 0.3368-1.424 μg. The recoveries of the four analytes were in the range of 76.1-88.9%. The relative standard deviations of intra- and interday precision ranged from 4.2 to 7.6%. Compared with other off-line methods, the present method obtained higher extraction yields for all four aromatic constituents. Finally, this method has been applied to the analysis of vanilla from different sources. On the basis of the results, the on-line supercritical fluid extraction-supercritical fluid chromatography method shows great promise in the analysis of aromatic constituents in natural products. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. On-line double isotope dilution laser ablation inductively coupled plasma mass spectrometry for the quantitative analysis of solid materials.

    Science.gov (United States)

    Fernández, Beatriz; Rodríguez-González, Pablo; García Alonso, J Ignacio; Malherbe, Julien; García-Fonseca, Sergio; Pereiro, Rosario; Sanz-Medel, Alfredo

    2014-12-03

    We report on the determination of trace elements in solid samples by the combination of on-line double isotope dilution and laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). The proposed method requires the sequential analysis of the sample and a certified natural abundance standard by on-line IDMS using the same isotopically-enriched spike solution. In this way, the mass fraction of the analyte in the sample can be directly referred to the certified standard so the previous characterization of the spike solution is not required. To validate the procedure, Sr, Rb and Pb were determined in certified reference materials with different matrices, including silicate glasses (SRM 610, 612 and 614) and powdered samples (PACS-2, SRM 2710a, SRM 1944, SRM 2702 and SRM 2780). The analysis of powdered samples was carried out both by the preparation of pressed pellets and by lithium borate fusion. Experimental results for the analysis of powdered samples were in agreement with the certified values for all materials. Relative standard deviations in the range of 6-21% for pressed pellets and 3-21% for fused solids were obtained from n=3 independent measurements. Minimal sample preparation, data treatment and consumption of the isotopically-enriched isotopes are the main advantages of the method over previously reported approaches. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. FI/SI on-line solvent extraction/back extraction preconcentration coupled to direct injection nebulization inductively coupled plasma mass spectrometry for determination of copper and lead

    DEFF Research Database (Denmark)

    Wang, Jianhua; Hansen, Elo Harald

    2002-01-01

    An automated sequential injection on-line preconcentration procedure for determination of trace levels of copper and lead via solvent extraction/back extraction coupled to ICP-MS is described. In citrate buffer of pH 3, neutral complexes between the analytes and the chelating reagent, ammonium...... loop, the content of which is subsequently introduced into the ICP-MS, via a direct injection high efficiency nebulizer (DIHEN), for quantification. Enrichment factors of 29.6 (Cu) and 23.3 (Pb), detection limits of 17 ng/l (Cu) and 11 ng/l (Pb), along with a sampling frequency of 13 s/h were obtained...

  8. On-line preconcentration and determination of chromium in parenteral solutions by inductively coupled plasma optical emission spectrometry

    International Nuclear Information System (INIS)

    Gil, R.A.; Cerutti, S.; Gasquez, J.A.; Olsina, R.A.; Martinez, L.D.

    2005-01-01

    A method for the preconcentration and speciation of chromium was developed. On-line preconcentration and determination were obtained using inductively coupled plasma optical emission spectrometry (ICP-OES) coupled with flow injection. To determinate the chromium (III) present in parenteral solutions, chromium was retained on activated carbon at pH 5.0. On the other hand, a step of reduction was necessary in order to determine total chromium content. The Cr(VI) concentration was then determined by difference between the total chromium concentration and that of Cr(III). A sensitivity enrichment factor of 70-fold was obtained with respect to the chromium determination by ICP-OES without preconcentration. The detection limit for the preconcentration of 25 ml of sample was 29 ng l -1 . The precision for the 10 replicate determinations at the 5 μg l -1 Cr level was 2.3% relative standard deviation, calculated with the peak heights. The calibration graph using the preconcentration method for chromium species was linear with a correlation coefficient of 0.9995 at levels near the detection limits up to at least 60 μg l -1 . The method can be applied to the determination and speciation of chromium in parenteral solutions

  9. Analysis of plant hormones by microemulsion electrokinetic capillary chromatography coupled with on-line large volume sample stacking.

    Science.gov (United States)

    Chen, Zongbao; Lin, Zian; Zhang, Lin; Cai, Yan; Zhang, Lan

    2012-04-07

    A novel method of microemulsion electrokinetic capillary chromatography (MEEKC) coupled with on-line large volume sample stacking was developed for the analysis of six plant hormones including indole-3-acetic acid, indole-3-butyric acid, indole-3-propionic acid, 1-naphthaleneacetic acid, abscisic acid and salicylic acid. Baseline separation of six plant hormones was achieved within 10 min by using the microemulsion background electrolyte containing a 97.2% (w/w) 10 mM borate buffer at pH 9.2, 1.0% (w/w) ethyl acetate as oil droplets, 0.6% (w/w) sodium dodecyl sulphate as surfactant and 1.2% (w/w) 1-butanol as cosurfactant. In addition, an on-line concentration method based on a large volume sample stacking technique and multiple wavelength detection was adopted for improving the detection sensitivity in order to determine trace level hormones in a real sample. The optimal method provided about 50-100 fold increase in detection sensitivity compared with a single MEEKC method, and the detection limits (S/N = 3) were between 0.005 and 0.02 μg mL(-1). The proposed method was simple, rapid and sensitive and could be applied to the determination of six plant hormones in spiked water samples, tobacco leaves and 1-naphthylacetic acid in leaf fertilizer. The recoveries ranged from 76.0% to 119.1%, and good reproducibilities were obtained with relative standard deviations (RSDs) less than 6.6%.

  10. Flow injection on-line oxidizing fluorometry coupled to dialysis sampling for the study of carbamazepine-protein binding

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Zhiqi [School of Chemistry and Materials Science, Shaanxi Normal University, Xi' an 710062 (China)]. E-mail: zqzhang@snnu.edu.cn; Liang Guoxi [School of Chemistry and Materials Science, Shaanxi Normal University, Xi' an 710062 (China)

    2005-04-22

    The mechanism of binding of carbamazepine (CBZ) with bovine serum albumin (BSA) has been investigated in vitro based on a new flow injection fluorometry coupled to the technique of dialysis sampling. The CBZ and BSA were mixed in different molar ratios in 0.050 mol L{sup -1} phosphate buffer (containing 0.9% NaCl), pH 7.4, and incubated at 37 {+-} 0.5 deg. C in a water bath. The dialysis sampler was utilized to sample free CBZ from mixed solution with a relative dialytic efficiency of 7.6%. Then the CBZ in dialysis solution was injected into carrier and on-line oxidized by lead dioxide solid-phase reactor into fluorescent product with a maximum excitation wavelength of 355 nm and a maximum emission wavelength of 478 nm. The fluorescence intensity measured was linear proportional with the concentration of free CBZ in mixed solution over the range of 1 x 10{sup -5} to 2 x 10{sup -4} mol L{sup -1} with the detection limit of 6 x 10{sup -6} mol L{sup -1}. According to the fluorescence measurement results from mixed solution, the association constant (K) estimated for CBZ-BSA binding and the number of the binding site (n) with Scatchard analysis were 1.08 x 10{sup 4} L mol{sup -1} and 0.94, respectively. Stern-Volmer plots indicated the presence of dynamic component in the quenching mechanism. The acting force was suggested to be mainly hydrophobic and the distance between the acceptor and donor was 3.12 nm. The estimated binding parameters agreed well with literature values.

  11. On-line coupling of sample preconcentration by LVSEP with gel electrophoretic separation on T-channel chips.

    Science.gov (United States)

    Kitagawa, Fumihiko; Kinami, Saeko; Takegawa, Yuuki; Nukatsuka, Isoshi; Sueyoshi, Kenji; Kawai, Takayuki; Otsuka, Koji

    2017-01-01

    To achieve an on-line coupling of the sample preconcentration by a large-volume sample stacking with an electroosmotic flow pump (LVSEP) with microchip gel electrophoresis (MCGE), a sample solution, a background solution for LVSEP and a sieving solution for MCGE were loaded in a T-form channel and three reservoirs on PDMS microchips. By utilizing the difference in the flow resistance of the two channels, a low-viscosity sample and a viscous polymer solution were easily introduced into the LVSEP and MCGE channels, respectively. Fluorescence imaging of the sequential LVSEP-MCGE processes clearly demonstrated that a faster stacking of anionic fluorescein and successive introduction into the MCGE channel can be carried out on the T-channel chip. To evaluate the preconcentration performance, a conventional MCZE analysis of fluorescein on the cross-channel chip was compared with LVSEP-MCGE on the short T-channel chip, and as a result that the value of sensitive enhancement factor (SEF) was estimated to be 370. The repeatability of the peak height was good with the RSD value of 3.2%, indicating the robustness of the enrichment performance. In the successive LVSEP-MCGE analysis of φX174/HaeIII digest, the DNA fragments were well enriched to a sharp peak in the LVSEP channel, and they were separated in the MCGE channel, whose electropherogram was well-resembled with that in the conventional MCGE. The values of SEF for the DNA fragments were calculated to be ranging from 74 to 108. Thus, the successive LVSEP-MCGE analysis was effective for both preconcentrating and separating DNA fragments. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Speciation analysis of inorganic arsenic by magnetic solid phase extraction on-line with inductively coupled mass spectrometry determination.

    Science.gov (United States)

    Montoro Leal, P; Vereda Alonso, E; López Guerrero, M M; Cordero, M T Siles; Cano Pavón, J M; García de Torres, A

    2018-07-01

    Arsenic, one of the main environmental pollutants and potent natural poison, is a chemical element that is spread throughout the Earth's crust. It is well known that the toxicity of arsenic is highly dependent on its chemical forms. Generally, the inorganic species are more toxic than its organics forms, and As(III) is 60 times more toxic than As(V). In environmental waters, arsenic exists predominantly in two chemical forms: As(III) and As(V). In view of these facts, fast, sensitive, accurate and simple analytical methods for the speciation of inorganic arsenic in environmental waters are required. In this work, a new magnetic solid phase extraction with a hydride generation system was coupled on line with inductively coupled plasma mass spectrometry (MSPE-HG-ICP-MS). The new system was based on the retention of As(III) and As(V) in two knotted reactors filled with (Fe 3 O 4 ) magnetic nanoparticles functionalized with [1,5-bis (2-pyridyl) 3-sulfophenylmethylene] thiocarbonohydrazide (PSTH-MNPs). As(III) and total inorganic As were sequentially eluted in different reduction conditions. The concentration of As(V) was obtained by subtracting As(III) from total As. The system runs in a fully automated way and the method has proved to have a wide linear range and to be precise, sensitive and fast. The detection limits found were 2.7 and 3.2 ng/L for As(III) and total As, respectively; with relative standard deviations (RSDs) of 2.5% and 2.7% and a sample throughput of 14.4 h -1 . In order to validate the developed method, several certified reference samples of environmental waters including sea water, were analyzed and the determined values were in good agreement with the certified values. The proposed method was successfully applied to the speciation analysis of inorganic arsenic in well-water and sea water. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. The application of HPLC with on-line coupled UV/MS-biochemical detection for isolation of an acetylcholinesterase inhibitor from Narcissus 'Sir Winston Churchill'

    NARCIS (Netherlands)

    Ingkaninan, K.; Hazekamp, A.; de Best, C.M.; Irth, H.; Tjaden, U.R.; van der Heijden, R.; van der Greef, J.; Verpoorte, R.

    2000-01-01

    An HPLC with on-line coupled UV/MS-biochemical detection method for acetylcholinesterase (AChE) inhibitors in natural sources has been developed. The potential of this method is shown by the isolation of a new AChE inhibitor from the alcoholic extract of Narcissus 'Sir Winston Churchill'. Combining

  14. Flow injection on-line dilution for multi-element determination in human urine with detection by inductively coupled plasma mass spectrometry

    DEFF Research Database (Denmark)

    Wang, Jianhua; Hansen, Elo Harald; Gammelgaard, Bente

    2001-01-01

    A simple flow injection on-line dilution procedure with detection by inductively coupled plasma mass spectrometry (ICP-MS) was developed for the determination of copper, zinc, arsenic, lead, selenium, nickel and molybdenum in human urine. Matrix effects were minimized by employing a dilution factor...

  15. Recent advances in on-line coupling of capillary electrophoresis to atomic absorption and fluorescence spectrometry for speciation analysis and studies of metal-biomolecule interactions

    International Nuclear Information System (INIS)

    Li Yan; Yin Xuebo; Yan Xiuping

    2008-01-01

    Speciation information is vital for the understanding of the toxicity, mobility and bioavailability of elements in environmental or biological samples. Hyphenating high resolving power of separation techniques and element-selective detectors provides powerful tools for studying speciation of trace elements in environmental and biological systems. During the last five years several novel hybrid techniques based on capillary electrophoresis (CE) and atomic spectrometry have been developed for speciation analysis and metal-biomolecule interaction study in our laboratory. These techniques include CE on-line coupled with atomic fluorescence spectrometry (AFS), chip-CE on-line coupled with AFS, CE on-line coupled with flame heated quartz furnace atomic absorption spectrometry (FHF-AAS), and CE on-line coupled with electrothermal atomic absorption spectrometry (ETAAS). The necessity for the development of these techniques, their interface design, and applications in speciation analysis and metal-biomolecule interaction study are reviewed. The advantages and limitations of the developed hybrid techniques are critically discussed, and further development is also prospected

  16. Determination of the sulfur mustard hydrolysis product thiodiglycol by microcolumn liquid chromatography coupled on-line with sulfur flame photometric detection using large-volume injections and peak

    NARCIS (Netherlands)

    Hooijschuur, E.W.J.; Kientz, C.E.; Brinkman, U.A.T.

    1999-01-01

    A selective, direct and relatively rapid method has been developed for the determination of thiodiglycol (TDG) in aqueous samples. TDG is the main hydrolysis product of the chemical warfare agent sulfur mustard. The method of analysis is based on the on-line coupling of reversed-phase microcolumn

  17. Automation of the helium jet transport system for nuclear recoil products; Automacao do sistema de transporte de nucleos de recuo por jato de helio

    Energy Technology Data Exchange (ETDEWEB)

    Bellido, Luis F.; Pedrosa, Paulo S

    1996-09-01

    A computer code and an interface hardware to automate the acquisition data and the sample changer in a helium jet transport system of recoil nucleus was developed for an IBM or compatible personal microcomputer. The software works with a Spectrum-ACE/ADCAM ORTEC`s multichannel analysers and the interface card uses the 03EFh port to command the sample changer. This system allows to measure, by gamma spectrometry, radionuclides with half-lives of order of seconds produced from nuclear reactions. (author) 3 refs.

  18. High-performance liquid chromatography on-line coupled to high-field NMR and mass spectrometry for structure elucidation of constituents of Hypericum perforatum L

    DEFF Research Database (Denmark)

    Hansen, S. H.; Jensen, A. G.; Cornett, Claus

    1999-01-01

    The on-line separation and structure elucidation of naphthodianthrones, flavonoids, and other constituents of an extract from Hypericum perforatum L, using high performance liquid chromatography (HPLC) coupled on-line with ultraviolet-visible, nuclear magnetic resonance (NMR), and mass spectrometry...... (MS) is described. A conventional reversed-phase HPLC system using ammonium acetate as the buffer substance in the eluent tvas used, and proton NMR spectra were obtained on a 500 MHz NMR instrument. The MS and MS/MS analyses were performed using negative electrospray ionization, In the present study...

  19. Determination of low cadmium concentrations in wine by on-line preconcentration in a knotted reactor coupled to an inductively coupled plasma optical emission spectrometer with ultrasonic nebulization

    Energy Technology Data Exchange (ETDEWEB)

    Lara, R.F. [Inst. de Investigaciones Mineras, Universidad Nacional de San Juan (Argentina); Wuilloud, R.G.; Salonia, J.A. [Dept. of Analytical Chemistry, National University of San Luis (Argentina); Olsina, R.A.; Martinez, L.D. [Dept. of Analytical Chemistry, National University of San Luis (Argentina); Consejo Nacional de Investigaciones Cientificas y Tecnicas (CONICET) (Argentina)

    2001-12-01

    An on-line cadmium preconcentration and determination system implemented with inductively coupled plasma optical emission spectrometry (ICP-OES) associated to flow injection (FI) with ultrasonic nebulization system (USN) was studied. The cadmium was retained as the cadmium-2-(5-bromo-2-pyridylazo)-5-diethylaminophenol, Cd-(5-Br-PADAP), complex, at pH 9.5. The cadmium complex was removed from the knotted reactor (KR) with 3.0 mol/L nitric acid. A total enhancement factor of 216 was obtained with respect to ICP-OES using pneumatic nebulization (12 for USN and 18 for KR) with a preconcentration time of 60 s. The value of the detection limit for the preconcentration of 5 mL of sample solution was 5 ng/L. The precision for 10 replicate determinations at the 5 {mu}g/L Cd level was 2.9% relative standard deviation (RSD), calculated from the peak heights obtained. The calibration graph using the preconcentration system for cadmium was linear with a correlation coefficient of 0.9998 at levels near the detection limits up to at least 1000 {mu}g/L. The method was successfully applied to the determination of cadmium in wine samples. (orig.)

  20. Trends and perspectives of flow injection/sequential injection on-line sample-pretreatment schemes coupled to ETAAS

    DEFF Research Database (Denmark)

    Wang, Jianhua; Hansen, Elo Harald

    2005-01-01

    Flow injection (FI) analysis, the first generation of this technique, became in the 1990s supplemented by its second generation, sequential injection (SI), and most recently by the third generation (i.e.,Lab-on-Valve). The dominant role played by FI in automatic, on-line, sample pretreatments in ...

  1. On-line coupling of physiologically relevant bioaccessibility testing to inductively coupled plasma spectrometry: Proof of concept for fast assessment of gastrointestinal bioaccessibility of micronutrients from soybeans.

    Science.gov (United States)

    Herrera, Mónica Alejandra; Rosende, María; Arruda, Marco Aurélio Zezzi; Miró, Manuel

    2016-10-05

    In-vitro physiologically relevant gastrointestinal extraction based on the validated Unified BARGE Method (UBM) is in this work hyphenated to inductively coupled plasma optical emission spectrometry in a batch-flow configuration for real-time monitoring of oral bioaccessibility assays with high temporal resolution. A fully automated flow analyzer is designed to foster in-line filtration of gastrointestinal extracts at predefined times (≤15 min) followed by on-line multi-elemental analysis of bioaccessible micro-nutrients, viz., Cu, Fe and Mn, in well-defined volumes of extracts (300 μL) of transgenic and non-transgenic soybean seeds taken as model samples. The hyphenated flow setup allows for recording of temporal extraction profiles to gain full knowledge of the kinetics of the gastrointestinal digestion processes, including element leaching and concomitant precipitation and complexation reactions hindering bioavailability. Simplification of the overall standard procedure is also feasible by identification of steady-state extraction conditions. Our findings indicate that reliable measurement of oral bioaccessible pools of Cu, Fe and Mn in soybean might be obtained in less than 180 min rather than 240 min as endorsed by UBM. Using a matrix-matched external calibration, limits of detection according to the 3s criteria were 0.5 μg/g for Mn, 0.6 μg/g for Cu and 2.3 μg/g for Fe. Trueness of the automatic bioaccessibility method was confirmed by mass balance validation with recoveries ranging from 87 to 116% regardless of the target element and sample. Cu was the micronutrient with the highest oral bioaccessibility ranging from 73% to 83% (7.5-7.9 μg/g) for non-transgenic and transgenic soybeans, respectively, followed by Mn and Fe within the ranges of 29-31% (10.8-11.4 μg/g) and 11-15% (8-14 μg/g), respectively, regardless of transgenesis. The proposed kinetic method is proven suitable for fast and expedient estimation of the nutritional value of

  2. Determination of total and inorganic mercury in fish samples with on-line oxidation coupled to atomic fluorescence spectrometry

    International Nuclear Information System (INIS)

    Shao Lijun; Gan Wuer; Su Qingde

    2006-01-01

    An atomic fluorescence spectrometry system for determination of total and inorganic mercury with electromagnetic induction-assisted heating on-line oxidation has been developed. Potassium peroxodisulphate was used as the oxidizing agent to decompose organomercury compounds. Depending on the temperature selected, inorganic or total mercury could be determined with the same manifold. Special accent was put on the study of the parameters influencing the on-line digestion efficiency. The tolerance to the interference of coexisting ions was carefully examined in this system. Under optimal conditions, the detection limits (3σ) were evaluated to be 2.9 ng l -1 for inorganic mercury and 2.6 ng l -1 for total mercury, respectively. The relative standard deviations for 10 replicate determinations of 1.0 μg l -1 Hg were 2.4 and 3.2% for inorganic mercury and total mercury, respectively. The proposed method was successfully applied to the determination of total and inorganic mercury in fish samples

  3. High-Efficiency On-Line Solid-Phase Extraction Coupling to 15-150 um I.D. Column Liquid Chromatography for Proteomic Analysis

    International Nuclear Information System (INIS)

    Shen, Yufeng; Moore, Ronald J.; Zhao, Rui; Blonder, Josip; Auberry, Deanna L.; Masselon, Christophe D.; Pasa Tolic, Ljiljana; Hixson, Kim K.; Auberry, Kenneth J.; Smith, Richard D.

    2003-01-01

    Flexible manipulation of various properties of proteomic samples is important for proteomic analyses, but it has been little explored for newly developed approaches based on liquid chromatography (LC) in combination with mass spectrometry (MS). With miniaturization of the LC column inner diameter dimensions (required for improving the analysis sensitivity), this issue becomes more challenging due to the small flow rates and the increasing effects of extra column volume on the separation quality and its use for resolving complex proteomic mixtures. In this study, we used commercial switching valves (150-mm channels) to implement the on-line coupling of capillary LC columns with relatively large solid phase extraction (SPE) columns operated at 10,000 psi. With optimized column connections, switching modes, and SPE column dimensions, high-efficiency on-line SPE-capillary and nanoscale LC separations were obtained with peak capacities of ∼1000 for capillaries having inner diameters between 15 to 150 mm. The on-line coupled SPE columns increased the sample processing capabilities by ∼400-fold for sample solution volume and ∼10-fold for sample mass. The proteomic applications of this on-line SPE-capillary LC system were evaluated for analysis of both soluble and membrane protein tryptic digests. Used with an ion trap tandem MS we could typically identify 1100-1500 peptides for analyses in a single 5-hour run. Peptides extracted on the SPE column and eluted from the LC column covered a hydrophilicity/hydrophobicity range that include an estimated ∼98% of all the tryptic peptides. The present implementation also facilitates automation and enables use of both disposable SPE columns and electrospray emitters, providing a robust basis for routine proteomic analyses.

  4. On-line coupling of the MAT 251 with a Carlo Erba elemental analyzer for carbon isotope ratio measurements

    International Nuclear Information System (INIS)

    Pichlmayer, F.

    1986-06-01

    For carbon isotope investigations with a moderate precision demand of about 0.2 per mil in the isotope ratio fast and reliable results are attained by on line combination of the ANA 1500 Elemental Analyzer and the MAT 251 Isotope Mass Spectrometer. The crucial point hereof is the gas splitting device. By proper design and adjustment of the analytical parameters, good sample efficiency and a sharp CO 2 bulk within the He stream is reached. The main characteristics of this combined equipment are described and some isotopic results of organic and anorganic carbon in lake sediment-samples are given as well as deltasup1 3 C-analyses of spiritous liquors. (Author)

  5. Critical comparison of the on-line and off-line molecularly imprinted solid-phase extraction of patulin coupled with liquid chromatography.

    Science.gov (United States)

    Lhotská, Ivona; Holznerová, Anežka; Solich, Petr; Šatínský, Dalibor

    2017-12-01

    Reaching trace amounts of mycotoxin contamination requires sensitive and selective analytical tools for their determination. Improving the selectivity of sample pretreatment steps covering new and modern extraction techniques is one way to achieve it. Molecularly imprinted polymers as selective sorbent for extraction undoubtedly meet these criteria. The presented work is focused on the hyphenation of on-line molecularly imprinted solid-phase extraction with a chromatography system using a column-switching approach. Making a critical comparison with a simultaneously developed off-line extraction procedure, evaluation of pros and cons of each method, and determining the reliability of both methods on a real sample analysis were carried out. Both high-performance liquid chromatography methods, using off-line extraction on molecularly imprinted polymer and an on-line column-switching approach, were validated, and the validation results were compared against each other. Although automation leads to significant time savings, fewer human errors, and required no handling of toxic solvents, it reached worse detection limits (15 versus 6 μg/L), worse recovery values (68.3-123.5 versus 81.2-109.9%), and worse efficiency throughout the entire clean-up process in comparison with the off-line extraction method. The difficulties encountered, the compromises made during the optimization of on-line coupling and their critical evaluation are presented in detail. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. On-line digestion in a focused microwave-assisted oven for elements determination in orange juice by inductively coupled plasma optical emission spectrometry

    Directory of Open Access Journals (Sweden)

    Fili Sabrina P.

    2003-01-01

    Full Text Available A flow injection system coupled to focused microwave-assisted oven was used for on-line orange juice sample digestion for determination of Ca, Cu, Fe, K, Mg, Mn, Na, P, and Zn by inductively coupled plasma optical emission spectrometry. The reactor coil was a PTFE tube (4.0 m long and 1.6 mm i.d. positioned into the commercial glass tube of the focused microwave oven. Aliquots of 500 muL of sample and 1000 muL of reagent (80% v/v HNO3 were mixed in a confluence and carried out to the reactor coil by air carrier. The relative standard deviation for five replicates of sample was lower than 5.0%. Good recoveries varying from 91 to 111% were obtained for added concentrations of the interest elements. The results obtained using the proposed digestion system are in agreement with those obtained for total digestion at the 95% confidence level. With this on-line digestion system was possible to carry out 12 samples h-1, minimizing contamination, saving consumption of samples and reagent and low residue generation.

  7. Tantala-based sol-gel coating for capillary microextraction on-line coupled to high-performance liquid chromatography.

    Science.gov (United States)

    Tran, MinhPhuong; Turner, Erica B; Segro, Scott S; Fang, Li; Seyyal, Emre; Malik, Abdul

    2017-11-03

    A sol-gel organic-inorganic hybrid sorbent, consisting of chemically integrated tantalum (V) ethoxide (TaEO) and polypropylene glycol methacrylate (PPGM), was developed for capillary microextraction (CME). The sol-gel sorbent was synthesized within a fused silica capillary through hydrolytic polycondensation of TaEO and chemical incorporation of PPGM into the evolving sol-gel tantala network. A part of the organic-inorganic hybrid sol-gel network evolving in the vicinity of the capillary walls had favorable conditions to get chemically bonded to the silanol groups on the capillary surface forming a surface-bonded coating. The newly developed sol-gel sorbent was employed to isolate and enrich a variety of analytes from aqueous samples for on-line analysis by high-performance liquid chromatography (HPLC) equipped with a UV detector. CME was performed on aqueous samples containing trace concentrations of analytes representing polycyclic aromatic hydrocarbons, ketones, alcohols, amines, nucleosides, and nucleotides. This sol-gel hybrid coating provided efficient extraction with CME-HPLC detection limits ranging from 4.41pM to 28.19 pM. Due to direct chemical bonding between the sol-gel sorbent coating and the fused silica capillary inner surface, this sol-gel sorbent exhibited enhanced solvent stability. The sol-gel tantala-based sorbent also exhibited excellent pH stability over a wide pH range (pH 0-pH 14). Furthermore, it displayed great performance reproducibility in CME-HPLC providing run-to-run HPLC peak area relative standard deviation (RSD) values between 0.23% and 3.83%. The capillary-to-capillary RSD (n=3), characterizing capillary preparation method reproducibility, ranged from 0.24% to 4.11%. The results show great performance consistency and application potential for the sol-gel tantala-PPGM sorbent in various fields including biomedical, pharmaceutical, and environmental areas. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. On-line system for preconcentration and determination of metals in vegetables by Inductively Coupled Plasma Optical Emission Spectrometry

    International Nuclear Information System (INIS)

    Bezerra, Marcos A.; Santos, Walter N.L. dos; Lemos, Valfredo A.; Korn, Maria das Gracas A.; Ferreira, Sergio L.C.

    2007-01-01

    A procedure has been developed for the simultaneous determination of trace amounts of cadmium, copper, chromium, nickel and lead in digested vegetable samples. The method involves solid-phase extraction of the metals using a minicolumn of Amberlite XAD-4 modified with dihydroxybenzoic acid (DHB) and detection by Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES). The elution of the metals from minicolumn was performed with 1.0 mol L -1 hydrochloric acid. Variables associated with flow preconcentration system performance, such as pH, buffer concentration, eluent concentration and sampling flow rate, were optimized. The developed procedure provides enrichment factors of 100, 72, 16, 91 and 53, for cadmium, copper, chromium, nickel and lead, respectively. Detection limits (3σ B ) were 0.02 (Cd), 0.23 (Cu), 0.58 (Cr), 0.060 (Ni) and 0.54 (Pb) μg L -1 . The procedure was applied for determination of metals in samples of guarana and cabbage. The accuracy of the method was checked by the analysis of a certified reference material (NIST 1571, Orchard leaves). Results found were in agreement with certified values

  9. On-line solid-phase extraction coupled to hydrophilic interaction chromatography-mass spectrometry for the determination of polar drugs.

    Science.gov (United States)

    Fontanals, Núria; Marcé, Rosa M; Borrull, Francesc

    2011-09-02

    The present study describes the first fully automated method based on on-line solid-phase extraction (SPE) coupled to hydrophilic interaction chromatography-electrospray-mass spectrometry (HILIC-(ESI)MS) to determine a group of polar drugs that includes illicit drugs (such as cocaine, morphine, codeine and metabolites) and pharmaceuticals in environmental water samples. The SPE was performed using a highly retentive polymeric sorbent. The HILIC separation was optimised and the initial high organic content of the chromatographic mobile phase, was also suitable for the proper on-line elution of the analytes retained in the SPE column and for enhancing the ESI ionisation efficiency. This method allows the loading of samples of up to 250ml of ultrapure water or 10ml of environmental water samples spiked at low ngl(-1) levels of the analytes. The method yields near 100% recoveries for all the analytes. The method was also validated with environmental water samples with linear ranges from 5 to 1000ngl(-1) and limits of detection ≤2ngl(-1) for most of the compounds. Copyright © 2010 Elsevier B.V. All rights reserved.

  10. Determination of organic and inorganic mercury species in Sungai Kinta, Perak by reversed-phase high performance liquid chromatography (HPLC) on-line coupled with ICP-MS

    International Nuclear Information System (INIS)

    Norshidah Baharuddin; Norashikin Saim; Rozita Osman; Sharifuddin Mohd Zain

    2012-01-01

    This paper describes a simple method for mercury speciation in river water samples of Sungai Kinta, Perak. Separation and measurement were done by high-performance liquid chromatography on-line with inductively coupled plasma mass spectrometry (HPLC/ ICP-MS). Separation of mercury species was accomplished within 6 minutes on an AQ C18 4.6 mm i.d x 150 mm, 5 μm reversed phase column with 0.1 % (w/ v) L-cysteine as mobile phase. Under the optimum instrumental conditions, recoveries of 101-104 % for MeHg + and 96 - 104 % for Hg 2+ were obtained with experimental detection limits of 1ngL -1 for inorganic mercury and 1.5 μgL -1 for organic mercury. (author)

  11. A simple method using on-line continuous leaching and ion exchange chromatography coupled to inductively coupled plasma mass spectrometry for the speciation analysis of bio-accessible arsenic in rice.

    Science.gov (United States)

    Horner, Nolan S; Beauchemin, Diane

    2012-03-02

    A simple method for the speciation analysis of bio-accessible arsenic (As) in rice was developed using a continuous on-line leaching method to release the bio-accessible fraction. The continuous on-line leaching method has several advantages over commonly used batch methods including quicker and easier sample preparation, reduced risk of contamination and access to real time leaching data. The bio-accessibility of As in the samples was monitored using inductively coupled plasma mass spectrometry (ICP-MS). Results from a certified reference material as well as cooked and uncooked white rice showed that the majority of As was leached by saliva. Results obtained using the continuous on-line leaching method were comparable to those obtained using a batch method. Speciation analysis of the saliva leachate was performed using ion exchange chromatography coupled to ICP-MS. The four most toxic forms of As (As(III), monomethylarsonic acid (MMA), dimethylarsinic acid (DMA) and As(V)) were clearly separated within 5 min in a single chromatographic run. Over 92% of bio-accessible As in the certified reference material and uncooked white rice sample was in the form of DMA and As(V), whereas it was present as DMA and As(III) in the cooked white rice. Copyright © 2011 Elsevier B.V. All rights reserved.

  12. Rapid determination of 99Tc in environmental samples by high resolution ICP-MS coupled with on-line flow injection system

    International Nuclear Information System (INIS)

    Kim, C.K.; Kim, C.S.; Rho, B.H.; Lee, J.I.

    2002-01-01

    High resolution inductively coupled plasma mass spectrometry coupled with an on-line flow injection system (FI-HR-ICP-MS) was applied to determine the ultra-trace level 99 Tc in soil. The flow injection system (PrepLab TM ) was composed of two TEVA-Spec R resins, reduced remarkably the sample amounts and the analysis time, compared to the conventional analytical methods. In the flow injection system, Mo and Ru were sufficiently eliminated by using the flow injection system, with the decontamination factors of 1.6 x 10 4 and 9.9 x 10 5 , respectively. With the present method, it was possible to determine ultra-low level of 99 Tc in 3∼6 soil at 3-5 hours of analysis time per sample. The relative standard deviation for each sample was less than 4%. The detection limits for 99 Tc was 85 fg x ml -1 (0.05 mBq x ml -1 ), which was calculated from the three times standard deviation of the count rate of the blank. (author)

  13. Automated on-line solid phase extraction coupled to HPLC-APCI-MS detection as a versatile tool for the analysis of phenols in water samples

    International Nuclear Information System (INIS)

    Wissiack, R.

    2001-05-01

    In this work a liquid chromatography-atmospheric pressure chemical ionization-mass spectrometry (HPLC-APCI-MS) technique was developed for the determination of phenols and anilines in waste water samples. All relevant parameters were optimized for liquid chromatographic (LC) separation and mass spectrometric (MS) detection. Mass spectrometric detection was used in either negative ionization (NI) or positive ionization (PI) mode, which was depending on the physicochemical properties of the analyte. For screening analysis, full scan mode (SCAN) was used, while selected ion monitoring (SIM) mode of acquisition was used for maximum sensitivity. The optimal interface parameters and solvent compositions were evaluated, which mainly determined the ionization of analytes thus strongly influencing the sensitivity. The quasi-molecular ions were the most abundant signals both for phenols ([M-H]- in NI) and for anilines ([M+H]+ in PI). In general, fragmentation was hardly observed for one-ring phenols. Only fragmentation due to neutral losses of NO, HCl, NH3, CO2, CHO or CO from the functional groups were obtained via collision induced dissociation (CID) in a single quadrupole mass spectrometer. A further source of structural information was the relative intensity of positive and negative ions for one analyte: Only in the case of para-methyl substituted phenols, detection was also possible in positive ionization mode with reasonable sensitivity. In contrast to the phenols, anilines offered somewhat higher structural information due to increased fragmentation through CID, when detected in the positive ionization mode. The main goal of this work was the development of a method for the determination of US EPA priority phenols in different environmental matrices. As highest sensitivity and selectivity was required for this task, a preconcentrating step was necessary, and consequently solid phase extraction (SPE) was coupled on-line to HPLC-APCI-MS. The optimized method allowed the

  14. Elemental ratios for characterization of quantum-dots populations in complex mixtures by asymmetrical flow field-flow fractionation on-line coupled to fluorescence and inductively coupled plasma mass spectrometry.

    Science.gov (United States)

    Menendez-Miranda, Mario; Fernandez-Arguelles, Maria T; Costa-Fernandez, Jose M; Encinar, Jorge Ruiz; Sanz-Medel, Alfredo

    2014-08-11

    Separation and identification of nanoparticles of different composition, with similar particle diameter, coexisting in heterogeneous suspensions of polymer-coated CdSe/ZnS quantum dots (QDs) have been thoroughly assessed by asymmetric flow field-flow fractionation (AF4) coupled on-line to fluorescence and inductively coupled plasma mass spectrometry (ICPMS) detectors. Chemical characterization of any previously on-line separated nanosized species was achieved by the measurement of the elemental molar ratios of every element involved in the synthesis of the QDs, using inorganic standards and external calibration by flow injection analysis (FIA). Such elemental molar ratios, strongly limited so far to pure single nanoparticles suspensions, have been achieved with adequate accuracy by coupling for the first time an ICP-QQQ instrument to an AF4 system. This hyphenation turned out to be instrumental to assess the chemical composition of the different populations of nanoparticles coexisting in the relatively complex mixtures, due to its capabilities to detect the hardly detectable elements involved in the synthesis. Interestingly such information, complementary to that obtained by fluorescence, was very valuable to detect and identify unexpected nanosized species, present at significant level, produced during QDs synthesis and hardly detectable by standard approaches. Copyright © 2014. Published by Elsevier B.V.

  15. Elemental ratios for characterization of quantum-dots populations in complex mixtures by asymmetrical flow field-flow fractionation on-line coupled to fluorescence and inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Menendez-Miranda, Mario; Fernandez-Arguelles, Maria T.; Costa-Fernandez, Jose M.; Encinar, Jorge Ruiz; Sanz-Medel, Alfredo

    2014-01-01

    Highlights: • The hyphenated system allows unequivocal identification of nanoparticle populations. • AF4 separation permitted detection of unexpected nanosized species in a sample. • ICP-QQQ provides elemental ratios with adequate accuracy in every nanoparticle. • Purity and chemical composition of different quantum dot samples were assessed. - Abstract: Separation and identification of nanoparticles of different composition, with similar particle diameter, coexisting in heterogeneous suspensions of polymer-coated CdSe/ZnS quantum dots (QDs) have been thoroughly assessed by asymmetric flow field-flow fractionation (AF4) coupled on-line to fluorescence and inductively coupled plasma mass spectrometry (ICPMS) detectors. Chemical characterization of any previously on-line separated nanosized species was achieved by the measurement of the elemental molar ratios of every element involved in the synthesis of the QDs, using inorganic standards and external calibration by flow injection analysis (FIA). Such elemental molar ratios, strongly limited so far to pure single nanoparticles suspensions, have been achieved with adequate accuracy by coupling for the first time an ICP-QQQ instrument to an AF4 system. This hyphenation turned out to be instrumental to assess the chemical composition of the different populations of nanoparticles coexisting in the relatively complex mixtures, due to its capabilities to detect the hardly detectable elements involved in the synthesis. Interestingly such information, complementary to that obtained by fluorescence, was very valuable to detect and identify unexpected nanosized species, present at significant level, produced during QDs synthesis and hardly detectable by standard approaches

  16. The determination of organochlorine pesticides based on dynamic microwave-assisted extraction coupled with on-line solid-phase extraction of high-performance liquid chromatography

    International Nuclear Information System (INIS)

    Chen Ligang; Ding Lan; Jin Haiyan; Song Daqian; Zhang Huarong; Li Jiantao; Zhang Kun; Wang Yutang; Zhang Hanqi

    2007-01-01

    A rapid technique based on dynamic microwave-assisted extraction coupled with on-line solid-phase extraction of high-performance liquid chromatography (DMAE-SPE-HPLC) has been developed. A TM 010 microwave resonance cavity built in the laboratory was applied to concentrate the microwave energy. The sample placed in the zone of microwave irradiation was extracted with 95% acetonitrile (ACN) aqueous solution which was driven by a peristaltic pump at a flow rate of 1.0 mL min -1 . The extraction can be completed in a recirculating system in 10 min. When a number of extraction cycles were completed, the extract (1 mL) was diluted on-line with water. Then the extract was loaded into an SPE column where the analytes were retained while the unretained matrix components were washed away. Subsequently, the analytes were automatically transferred from the SPE column to the analytical column and determined by UV detector at 238 nm. The technique was used for determination of organochlorine pesticides (OCPs) in grains, including wheat, rice, corn and bean. The limits of detection of OCPs are in the range of 19-37 ng g -1 . The recoveries obtained by analyzing the four spiked grain samples are in the range of 86-105%, whereas the relative standard deviation (R.S.D.) values are <8.7% ranging from 1.2 to 8.7%. Our method was demonstrated to be fast, accurate, and precise. In addition, only small quantities of solvent and sample were required

  17. Rapid determination of 18 glucocorticoids in serum using reusable on-line SPE polymeric monolithic column coupled with LC-quadrupole/orbitrap high-resolution mass spectrometer.

    Science.gov (United States)

    Li, Hui; Ai, Lianfeng; Fan, Sufang; Wang, Yan; Sun, Dianxing

    2017-10-15

    A simple, rapid and sensitive method for the simultaneous determination of 18 glucocorticoids in serum was developed by coupling on-line solid-phase extraction (SPE) polymeric monolithic column to a liquid chromatography-quadrupole/orbitrap high-resolution mass spectrometer. A simple poly(ethylene glycol dimethacrylate) monolith column (10mm×2.1mm i.d.) was fabricated, and the morphology, surface area and extraction performance of the monolithic column were characterized. Serum samples were extracted by acetonitrile (ACN). Then, online SPE was achieved on the synthesized monolithic column using a 10mmol/L ammonium acetate solution as the loading solvent. After the transfer from the monolith into analytical column (Capcell Pak ADME column) using ACN, the adsorbed analytes were separated on the analytical column and detected with a high-resolution hybrid quadrupole/orbitrap mass spectrometer with full scan/ddMS 2 scan mode Under optimized conditions, the method was linear with target linear correlation coefficient (R 2 ) higher than 0.995. Detection limits were in range of 0.1-0.6ng/mL, and the quantification limits were 0.3-1.5ng/mL. The recovery was between 71.9% and 89.2% in three spike levels with precision (n=5) of 5.40-12.1%. The serum sample was directly analyzed after a simple extraction procedure, and the on-line SPE and determination were achieved within only 16min. The method was used to analyze the dynamic contents variation of cortisone and hydrocortisone in serum before and after the surgery. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Simultaneous determination of metolazone and valsartan in plasma by on-line SPE coupled with liquid chromatography/tandem mass spectrometry.

    Science.gov (United States)

    Zhou, Jiezhao; Chen, Meiling; Li, Ying; Yu, Fanglin; Cheng, Xiaohui; Yang, Yang; Liu, Yan; Xie, Xiangyang; Li, Zhiping; Zhang, Hui; Mei, Xingguo

    2017-10-01

    Combination of metolazone (0.5 mg) and valsartan (80 mg) has been verified as a promising therapy treatment for hypertension. In order to facilitate to pharmacokinetic research, it needs a method for the simultaneously determination of metolazone and valsartan in biological samples. However, there are no relative reports so far. In order to facilitate to pharmacokinetic research, an on-line solid phase extraction coupled with liquid chromatography-tandem mass spectrometry method for the simultaneous determination of metolazone and valsartan in beagle dog plasma was developed and validated in this study. An on-line solid phase extraction column Retain PEP Javelin (10 mm × 2.1 mm) was used to remove impurities in plasma samples. The metolazone, valsartan and internal standard (losartan) were separated on a Poroshell 120 SB-C18 column (4.6 mm × 50 mm × 2.7 µm) with a gradient elution procedure. Acidified acetonitrile/water mixture was used as a mobile phase. The selected multiple-reaction monitoring mode in positive ion was performed and the parent to the product transitions m/z 366/259, m/z 436.2/291 and m/z 423.4/207 were used to measure the metolazone, valsartan and losartan. The method was linear over the range of 0.1-100 ng/mL and 1-1000 ng/mL for metolazone and valsartan, respectively. This method was validated in terms of specificity, linearity, sensitivity, precision, accuracy, matrix effect, and stability and then successfully applied to pharmacokinetic studies of the metolazone and valsartan combination tablets in beagle dogs.

  19. Modified mesoporous silica materials for on-line separation and preconcentration of hexavalent chromium using a microcolumn coupled with flame atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Wang Zheng, E-mail: wangzheng@mail.sic.ac.cn [Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai 200050 (China); Fang Dongmei; Li Qing [Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai 200050 (China); East China University of Science and Technology, Shanghai 200237 (China); Zhang Lingxia; Qian Rong; Zhu Yan; Qu Haiyun [Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai 200050 (China); Du Yiping [East China University of Science and Technology, Shanghai 200237 (China)

    2012-05-06

    Highlights: Black-Right-Pointing-Pointer A modified SBA-15 mesoporous silica material (NH{sub 2}-SBA-15) was synthesized as sorbent. Black-Right-Pointing-Pointer The material was used for the first time in a flow injection on-line solid phase extraction (SPE) coupled with flame atomic absorption spectrometry (FAAS) to detect trace Cr (VI). Black-Right-Pointing-Pointer The NH{sub 2}-SBA-15 enables retain Cr (VI) with an enrichment factor of 44. Black-Right-Pointing-Pointer The micro-column of NH{sub 2}-SBA-15 underwent more than 100 adsorption/desorption cycles. - Abstract: A modified SBA-15 mesoporous silica material NH{sub 2}-SBA-15 was synthesized successfully by grafting {gamma}-aminopropyl-triethoxysilane. The material was characterized using transmission electron microscopy (TEM) and Fourier transform infrared/Raman (FT-IR/Raman) spectroscopy, and used for the first time in a flow injection on-line solid phase extraction (SPE) coupled with flame atomic absorption spectrometry (FAAS) to detect trace Cr (VI). Effective sorption of Cr (VI) was achieved at pH 2.0 with no interference from Cr (III) and other ions and 0.5 mol L{sup -1} NH{sub 3}{center_dot}H{sub 2}O solution was found optimal for the complete elution of Cr (VI). An enrichment factor of 44 and was achieved under optimized experimental conditions at a sample loading of 2.0 mL min{sup -1} sample loading (300 s) and an elution flow rate of 2.0 mL min{sup -1} (24 s). The precision of the 11 replicate Cr (VI) measurements was 2.1% at the 100 {mu}g L{sup -1} level with a detection limit of 0.2 {mu}g L{sup -1} (3 s, n = 10) using the FAAS. The developed method was successfully applied to trace chromium determination in waste water. The accuracy was validated using a certified reference material of riverine water (GBW08607).

  20. On-line coupling of size exclusion chromatography with mixed-mode liquid chromatography for comprehensive profiling of biopharmaceutical drug product.

    Science.gov (United States)

    He, Yan; Friese, Olga V; Schlittler, Michele R; Wang, Qian; Yang, Xun; Bass, Laura A; Jones, Michael T

    2012-11-02

    A methodology based on on-line coupling of size exclusion chromatography (SEC) with mixed-mode liquid chromatography (LC) has been developed. The method allows for simultaneous measurement of a wide range of components in biopharmaceutical drug products. These components include the active pharmaceutical ingredient (protein) and various kinds of excipients such as cations, anions, nonionic hydrophobic surfactant and hydrophilic sugars. Dual short SEC columns are used to separate small molecule excipients from large protein molecules. The separated protein is quantified using a UV detector at 280 nm. The isolated excipients are switched, online, to the Trinity P1 mixed-mode column for separation, and detected by an evaporative light scattering detector (ELSD). Using a stationary phase with 1.7 μm particles in SEC allows for the use of volatile buffers for both SEC and mix-mode separation. This facilitates the detection of different excipients by ELSD and provides potential for online characterization of the protein with mass spectrometry (MS). The method has been applied to quantitate protein and excipients in different biopharmaceutical drug products including monoclonal antibodies (mAb), antibody drug conjugates (ADC) and vaccines. Copyright © 2012 Elsevier B.V. All rights reserved.

  1. Detection of radiation-induced hydrocarbons in irradiated fish and prawns by means of on-line coupled liquid chromatography-gas chromatography

    International Nuclear Information System (INIS)

    Schulzki, G.; Spiegelberg, A.; Bogl, K.W.; Schreiberg, G.A.

    1997-01-01

    Radiation-induced hydrocarbons were analyzed in a fatty (halibut) and a lean fish (cod) as well as in a prawn species by on-line coupled liquid chromatography (LC) -gas chromatography (GC) combined with mass spectrometry. In irradiated halibut which is known to contain mainly saturated and monounsaturated fatty acids, all expected radiolytic alkanes, alkenes, and alkadienes could be detected. The yields of the C(n-1) and C(n-2:1) hydrocarbons were comparable to those found in irradiated lipids of terrestrial animals and plants. However, in cod and prawns which contain high levels of polyunsaturated fatty acids (PUFA), the C(n-1) hydrocarbons were found in concentrations which were up to 10 times higher whereas the C(n-2:1) products were again comparable to those of terrestrial animals and plants. The identification of radiation-induced hydrocarbons in fish lipids was achieved by transfer of the hydrocarbons from the LC column to the gas chromatographic column in fractions differing in their degree of unsaturation. For the first time, radiation-induced hydrocarbons with more than four double bonds generated from polyunsaturated fatty acids (20:4 omega 6 and 20:5 omega 3) could be identified

  2. Identification of radiation-induced hydrocarbons in halibut, cod and prawns by on-line coupled LC-GC/MS technique

    International Nuclear Information System (INIS)

    Spiegelberg, A.; Schulzki, G.; Boegl, K.W.; Schreiber, G.A.

    1997-01-01

    Radiation-induced hydrocarbons were analysed in a fatty (halibut) and a lean fish (cod) as well as in a prawn species by on-line coupled liquid chromatography (LC) - gas chromatography (GC) combined with mass spectrometrical detection. In irradiated halibut which contains mainly saturated and monounsaturated fatty acids all expected radiolytic alkanes, alkenes and alkadienes could be detected. The yields of the C n-1 and C n-2:1 hydrocarbons were comparable with those found in irradiated lipids of land animals and plants. However, in cod and the prawn species which contain high levels of polyunsaturated fatty acids (PUFA), the C n-1 hydrocarbons were found in concentrations up to tenfold higher whereas the C n-2:1 products were again comparable to those of land animals and plants. The identification of radiation-induced hydrocarbons in fish lipids was achieved by transfer of the hydrocarbons from the LC column to the gas chromatographic column in fractions differing in the degree of unsaturation. For the first time radiation induced hydrocarbons with more than four double bonds generated from polyunsaturated fatty acids (20:4ω6 and 20:5ω3) could be identified. (orig.) [de

  3. Determination of biocides and pesticides by on-line solid phase extraction coupled with mass spectrometry and their behaviour in wastewater and surface water

    International Nuclear Information System (INIS)

    Singer, Heinz; Jaus, Sylvia; Hanke, Irene; Lueck, Alfred; Hollender, Juliane; Alder, Alfredo C.

    2010-01-01

    This study focused on the input of hydrophilic biocides into the aquatic environment and on the efficiency of their removal in conventional wastewater treatment by a mass flux analysis. A fully automated method consisting of on-line solid phase extraction coupled to LC-ESI-MS/MS was developed and validated for the simultaneous trace determination of different biocidal compounds (1,2-benzisothiazoline-3-one (BIT), 3-Iodo-2-propynylbutyl-carbamate (IPBC), irgarol 1051 and 2-N-octyl-4-isothiazolinone (octhilinone, OIT), carbendazim, diazinon, diuron, isoproturon, mecoprop, terbutryn and terbutylazine) and pharmaceuticals (diclofenac and sulfamethoxazole) in wastewater and surface water. In the tertiary effluent, the highest average concentrations were determined for mecoprop (1010 ng/L) which was at comparable levels as the pharmaceuticals diclofenac (690 ng/L) and sulfamethoxazole (140 ng/L) but 1-2 orders of magnitude higher than the other biocidal compounds. Average eliminations for all compounds were usually below 50%. During rain events, increased residual amounts of biocidal contaminants are discharged to receiving surface waters. - Incomplete removal of biocides and pesticides during wastewater treatment.

  4. Determination of biocides and pesticides by on-line solid phase extraction coupled with mass spectrometry and their behaviour in wastewater and surface water

    Energy Technology Data Exchange (ETDEWEB)

    Singer, Heinz; Jaus, Sylvia; Hanke, Irene; Lueck, Alfred; Hollender, Juliane [Eawag, Swiss Federal Institute of Aquatic Science and Technology, Ueberlandstrasse 133, CH-8600 Duebendorf (Switzerland); Alder, Alfredo C., E-mail: alfredo.alder@eawag.c [Eawag, Swiss Federal Institute of Aquatic Science and Technology, Ueberlandstrasse 133, CH-8600 Duebendorf (Switzerland)

    2010-10-15

    This study focused on the input of hydrophilic biocides into the aquatic environment and on the efficiency of their removal in conventional wastewater treatment by a mass flux analysis. A fully automated method consisting of on-line solid phase extraction coupled to LC-ESI-MS/MS was developed and validated for the simultaneous trace determination of different biocidal compounds (1,2-benzisothiazoline-3-one (BIT), 3-Iodo-2-propynylbutyl-carbamate (IPBC), irgarol 1051 and 2-N-octyl-4-isothiazolinone (octhilinone, OIT), carbendazim, diazinon, diuron, isoproturon, mecoprop, terbutryn and terbutylazine) and pharmaceuticals (diclofenac and sulfamethoxazole) in wastewater and surface water. In the tertiary effluent, the highest average concentrations were determined for mecoprop (1010 ng/L) which was at comparable levels as the pharmaceuticals diclofenac (690 ng/L) and sulfamethoxazole (140 ng/L) but 1-2 orders of magnitude higher than the other biocidal compounds. Average eliminations for all compounds were usually below 50%. During rain events, increased residual amounts of biocidal contaminants are discharged to receiving surface waters. - Incomplete removal of biocides and pesticides during wastewater treatment.

  5. Characterisation of organic compounds in aerosol particles from a finnish forest by on-line coupled supercritical fluid extraction-liquid chromatography-gas chromatography-mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Shimmo, Masahiko; Jaentti, Jaana; Hartonen, Kari; Hyoetylaeinen, Tuulia; Riekkola, Marja-Liisa [Laboratory of Analytical Chemistry, Department of Chemistry, University of Helsinki, P.O. Box 55, 00014, Helsinki (Finland); Aalto, Pasi; Kulmala, Markku [Division of Atmospheric Sciences, Department of Physical Sciences, University of Helsinki, P.O. Box 64, 00014, Helsinki (Finland)

    2004-04-01

    During the European Union project Quantification of Aerosol Nucleation in the European Boundary Layer (QUEST), which began in spring 2003, atmospheric aerosol particles were collected in a Finnish Scots pine forest using a high-volume sampler. The organic compounds in the filter samples were then analysed by on-line coupled supercritical fluid extraction-liquid chromatography-gas chromatography-mass spectrometry (SFE-LC-GC-MS). The sample was first extracted by SFE. During LC the extracts were fractionated into three fractions according to polarity. The final separation was carried out by GC-MS. A fraction volume as high as 840 {mu}L was transferred to the GC, using the partial concurrent eluent evaporation technique. The same instrumentation, with an in-situ SFE derivatisation method, was used to analyse organic acids. Major compounds such as n-alkanes and PAH were analysed quantitatively. Their concentrations were lower than those usually observed in urban areas or in other forest areas in Europe. The wind direction was one of the most important factors affecting changes in the daily concentrations of these compounds. Scots pine needles were analysed with the same system to obtain reference data for identification of biogenic compounds in aerosol particles. Other organic compounds found in this study included hopanes, steranes, n-alkanals, n-alkan-2-ones, oxy-PAH, and alkyl-PAH; some biogenic products, including oxidation products of monoterpenes, were also identified. (orig.)

  6. Target and ion source developments for a helium-jet type ISOL at the Kyoto university reactor

    International Nuclear Information System (INIS)

    Kawase, Yoichi; Okano, Kotoyuki; Funakoshi, Yoshihiro

    1985-01-01

    A target system and ion sources for a He-jet type ISOL have been successfully constructed and the characteristics have been studied. The beam intensities of short-lived fission products have been much improved by increasing the He gas pressure owing to a range effect of fission products in the He gas and a short transport time effect of aerosols in a target chamber and a capillary. An oscillating electron ion source has been coupled with the He-jet system and ten kinds of elements have been ionized with efficiencies of 0.4-2.4%. A high temperature thermal ion source has been studied to ionize the alkali, alkaline-earth and rare-earth elements. The effects of the He-jet on the ion source have been discussed. (orig.)

  7. Detection of radiation-induced hydrocarbons in Camembert irradiated before and after the maturing process-comparison of florisil column chromatography and on-line coupled liquid chromatography-gas chromatography

    International Nuclear Information System (INIS)

    Schulzki, G.; Spiegelberg, A.; Bögl, K.W.; Schreiber, G.A.

    1995-01-01

    The influence of the maturing process on the detection of radiation-induced volatile hydrocarbons in the fat of Camembert has been investigated. Two analytical methods for separation of the hydrocarbon fraction from the lipid were applied: Florisil column chromatography with subsequent gas chromatographic-mass spectrometric (GC-MS) determination as well as on-line coupled liquid chromatography-GC-MS. The maturing process had no influence on the detection of radiation-induced volatiles. Comparable results were achieved with both analytical methods. However, preference is given to the more effective on-line coupled LC-GC method

  8. Analysis of heterocyclic amines in hair by on-line in-tube solid-phase microextraction coupled with liquid chromatography−tandem mass spectrometry

    International Nuclear Information System (INIS)

    Kataoka, Hiroyuki; Inoue, Tsutomu; Saito, Keita; Kato, Hisato; Masuda, Kazufumi

    2013-01-01

    Graphical abstract: Mutagenic and carcinogenic heterocyclic amines are accumulated in the hair of smoker. -- Highlights: •On-line in-tube solid-phase microextraction of heterocyclic amines was optimized. •Fourteen heterocyclic amines were simultaneously determined by LC–MS/MS. •Pico gram levels of heterocyclic amines could be easily analyzed within 15 min. •Heterocyclic amines could be quantitatively analyzed from several milligrams of hair. •The method is useful for the assessment of long-term exposure to heterocyclic amines. -- Abstract: Mutagenic and carcinogenic heterocyclic amines (HCAs) are formed during heating of various proteinaceous foods, but human exposure to HCAs has not yet been elucidated in detail. To assess long-term exposure to HCAs, we developed a simple and sensitive method for measuring HCAs in hair by automated on-line in-tube solid-phase microextraction (SPME) coupled with liquid chromatography–tandem mass spectrometry (LC–MS/MS). Using a Zorbax Eclipse XDB-C8 column, 16 HCAs were analyzed within 15 min. The optimum in-tube SPME conditions were 20 draw/eject cycles of 40 μL sample at a flow rate of 200 μL min −1 using a Supel-Q PLOT capillary column as an extraction device. The extracted HCAs were easily desorbed from the column by passage of the mobile phase, with no carryover observed. This in-tube SPME LC–MS/MS method showed good linearity for HCAs in the range of 10–2000 pg mL −1 , with correlation coefficients above 0.9989 (n = 18), using stable isotope-labeled HCA internal standards. The detection limits (S/N = 3) of 14 HCAs except for MeAαC and Glu-P-1 were 0.10–0.79 pg mL −1 . This method was successfully utilized to analyze 14 HCAs in hair samples without any interference peaks, with quantitative limits (S/N = 10) of about 0.17–1.32 pg mg −1 hair. Using this method, we evaluated the exposure to HCAs in cigarette smoke and the suitability of using hair HCAs as exposure biomarkers

  9. Evaluation of slurry preparation procedures for the determination of mercury by axial view inductively coupled plasma optical emission spectrometry using on-line cold vapor generation

    International Nuclear Information System (INIS)

    Santos, Eder Jose dos; Herrmann, Amanda Beatriz; Antunes Vieira, Mariana; Azzolin Frescura, Vera Lucia; Curtius, Adilson Jose

    2005-01-01

    Five different slurry preparation procedures were tested, after grinding the solid samples to a particle size ≤53 μm: (1) using aqua regia plus HF, 30 min of sonication, standing time of 24 h followed by another 30 min of sonication; (2) same as the previous one, except that the standing time and the second ultrasound treatment were omitted; (3) same as the previous one, except that HF was not used; (4) same as the previous one, except that the aqua regia was replaced by nitric acid; (5) same as the previous one, except that the acid nitric was replaced by tetramethylammonium hydroxide (TMAH). The Hg vapor was generated on-line, and the emission signal intensity measured at 253.652 nm by axial view inductively coupled plasma optical emission spectrometry. Initially, four experimental conditions were optimized using a multivariate factorial analysis: the concentrations of HCl and of the reducing agent, NaBH 4 , used in the cold vapor generation, and two instrumental parameters, the plasma radiofrequency power and the carrier gas flow rate. The radiofrequency power was statistically significant, but limited to 1.2 kW for practical reasons. The procedures were applied to 11 biological and environmental materials. Both, the slurries and the filtrates were analyzed, using calibration solutions in the same medium as in the slurries. The first three procedures produced results in agreement with the certified values. The two last procedures, using nitric acid or TMHA could not be used for quantitative analysis. For practical reasons, Procedure 3, with a detection limit (3s, n=10) of 0.06 μg g -1 for a sample mass of 20 mg in a final volume of 15 mL is recommended. The relative standard deviations for mercury in the investigated materials, using the recommended procedure, were lower than 12.5%, indicating a good precision for slurry sampling. The recommended procedure is simple, rapid and robust

  10. Estimation of the bio-accessible fraction of Cr, As, Cd and Pb in locally available bread using on-line continuous leaching method coupled to inductively coupled plasma mass spectrometry.

    Science.gov (United States)

    Lamsal, Ram P; Beauchemin, Diane

    2015-03-31

    A previously developed, efficient and simple on-line leaching method was used to assess the maximum bio-accessible fraction (assuming no synergistic effect from other food and beverage) of potentially toxic elements (Cr, As, Cd and Pb) in whole wheat brown and white bread samples. Artificial saliva, gastric juice and intestinal juice were successively pumped into a mini-column, packed with bread (maintained at 37 °C) connected on-line to the nebulizer of an inductively coupled plasma mass spectrometry (ICP-MS) instrument equipped with a collision-reaction interface (CRI) using hydrogen as reaction gas to minimize carbon- and chlorine-based polyatomic interferences. In contrast to the conventional batch method to which it was compared, this approach provides real-time monitoring of potentially toxic elements that are continuously released during leaching. Mass balance for both methods was verified at the 95% confidence level. Results obtained from the whole wheat brown and white bread showed that the majority of Cr, Cd and Pb was leached by gastric juice but, in contrast, the majority of As was leached by saliva. While there was higher total content for elements in whole wheat bread than in white bread, a higher percentage of elements were bio-accessible in white bread than in whole wheat bread. Both the on-line and batch methods indicate that 40-98% of toxic elements in bread samples are bio-accessible. While comparison of total analyte concentrations with provisional tolerable daily intake values may indicate some serious health concern for children, when accounting for the bio-accessibility of these elements, bread consumption is found to be safe for all ages. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. SPECIATION OF SELENIUM AND ARSENIC COMPOUNDS BY CAPILLARY ELECTROPHORESIS WITH HYDRODYNAMICALLY MODIFIED ELECTROOSMOTIC FLOW AND ON-LINE REDUCTION OF SELENIUM(VI) TO SELENIUM(IV) WITH HYDRIDE GENERATION INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRIC DETECTION

    Science.gov (United States)

    Capillary electrophoresis (CE) with hydride generation inductively coupled plasma mass spectrometry was used to determine four arsenicals and two selenium species. Selenate (SeVI) was reduced on-line to selenite (SeIV') by mixing the CE effluent with concentrated HCl. A microporo...

  12. An automated method for the analysis of phenolic acids in plasma based on ion-pairing micro-extraction coupled on-line to gas chromatography/mass spectrometry with in-liner derivatisation

    NARCIS (Netherlands)

    Peters, S.; Kaal, E.; Horsting, I.; Janssen, H.-G.

    2012-01-01

    A new method is presented for the analysis of phenolic acids in plasma based on ion-pairing ‘Micro-extraction in packed sorbent’ (MEPS) coupled on-line to in-liner derivatisation-gas chromatography-mass spectrometry (GC-MS). The ion-pairing reagent served a dual purpose. It was used both to improve

  13. Quantitative analysis of higher hydrocarbons in natural gas using coupled solid-phase extraction / supercritiacal fluid extraction with on-line GC analysis

    NARCIS (Netherlands)

    Janssen, J.G.M.; Cramers, C.A.M.G.; Meulen-Kuijk, van der L.; Smit, A.L.C.; Sandra, P.; Devos, G.

    1993-01-01

    Characterisation of natural gas with respect to the hydrocarbon content is a challenging analytical problem due to the extremely low concentrations and the complexity of the matrix. In this publication a method is described for fully on-line preconcentration and analysis of n-nonane and higher

  14. On-line sample-pre-treatment schemes for trace-level determinations of metals by coupling flow injection or sequential injection with ICP-MS

    DEFF Research Database (Denmark)

    Wang, Jianhua; Hansen, Elo Harald

    2003-01-01

    a polytetrafluoroethylene (PTFE) knotted reactor (KR), solvent extraction-back extraction and hydride/vapor generation. It also addresses a novel, robust approach, whereby the protocol of SI-LOV-bead injection (BI) on-line separation and pre-concentration of ultra-trace levels of metals by a renewable microcolumn...

  15. Comparison of ultra-violet and inductively coupled plasma-atomic emission spectrometry for the on-line quantification of selenium species after their separation by reversed-phase liquid chromatography

    International Nuclear Information System (INIS)

    Tsopelas, Fotios N.; Ochsenkuehn-Petropoulou, Maria Th.; Mergias, Ioannis G.; Tsakanika, Lambrini V.

    2005-01-01

    An analytical approach for selenium speciation using liquid chromatography (LC) coupled with ultra-violet (UV) and inductively coupled plasma-atomic emission spectrometry (ICP-AES) was developed. The separation of the investigated selenium species, selenites, selenates, selenomethionine, selenocystine, selenocystamine and dimethyldiselenide was accomplished in less than 6 min on a BIO Wide Pore RP-18 column using sodium salt of n-octanesulfonic acid as ion-pairing modifier. The on-line detection of the separated selenium species was performed using UV spectrometry at the optimum wavelength of 192 nm, obtained by the UV spectra of the investigated individual selenium species. ICP-AES was also used as element specific on-line detector, after its coupling with the chromatographic system. The UV and ICP-AES detectors were compared for their suitability, including sensitivity and detection limits, for the on-line quantification of the six selenium species. The developed LC-UV as well as LC-ICP-AES techniques were successfully applied to a selenized yeast candidate reference material, after its enzymatic extraction with protease XIV. It was found that the described LC-UV technique is suitable for the determination of selenomethionine, the main selenium compound in the yeast, with an accuracy of 5%, although the UV detector is not element specific and it is rarely used for selenium speciation. This finding can prove valuable for routine laboratories to perform selenium speciation in such materials

  16. On-line coupling of counter-current chromatography and macroporous resin chromatography for continuous isolation of arctiin from the fruit of Arctium lappa L.

    Science.gov (United States)

    Guo, Mengzhe; Liang, Junling; Wu, Shihua

    2010-08-13

    In this work, we have developed a novel hybrid two-dimensional counter-current chromatography and liquid chromatography (2D CCC x LC) system for the continuous purification of arctiin from crude extract of Arctium lappa. The first dimensional CCC column has been designed to fractionalize crude complex extract into pure arctiin effluent using a one-component organic/salt-containing system, and the second dimensional LC column has been packed with macroporous resin for on-line adsorption, desalination and desorption of arctiin which was effluent purified from the first CCC dimension. Thus, the crude arctiin mixture has been purified efficiently and conveniently by on-line CCC x LC in spite of the use of a salt-containing solvent system in CCC separation. As a result, high purity (more than 97%) of arctiin has been isolated by repeated injections both using the ethyl acetate-8% sodium chloride aqueous solution and butanol-1% sodium chloride aqueous solution. By contrast with the traditional CCC processes using multi-component organic/aqueous solvent systems, the present on-line CCC x LC process only used a one-component organic solvent and thus the solvent is easier to recover and regenerate. All of used solvents such as ethyl acetate, n-butanol and NaCl aqueous solution are low toxicity and environment-friendly. Moreover, the lower phase of salt-containing aqueous solution used as mobile phase, only contained minor organic solvent, which will save much organic solvent in continuous separation. In summary, our results indicated that the on-line hybrid 2D CCC x LC system using one-component organic/salt-containing aqueous solution is very promising and powerful tool for high-throughput purification of arctiin from fruits of A. lappa. 2010 Elsevier B.V. All rights reserved.

  17. Determination of lycopene in food by on-line SFE coupled to HPLC using a single monolithic column for trapping and separation

    Czech Academy of Sciences Publication Activity Database

    Pól, Jaroslav; Hyötyläinen, T.; Ranta-Aho, O.; Riekkola, M. L.

    2004-01-01

    Roč. 1052, 1-2 (2004), s. 25-31 ISSN 0021-9673 R&D Projects: GA AV ČR KJB4031405 Grant - others:Academy of Finland Projects(FI) 48867; Academy of Finland Projects(FI) 52746 Institutional research plan: CEZ:AV0Z4031919 Keywords : lycopene * on-line SFE-LC * supercritical fluid extraction Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 3.359, year: 2004

  18. Rapid Determination of Two Triterpenoid Acids in Chaenomelis Fructus Using Supercritical Fluid Extraction On-line Coupled with Supercritical Fluid Chromatography.

    Science.gov (United States)

    Zhang, Xiaotian; Ji, Feng; Li, Yueqi; He, Tian; Han, Ya; Wang, Daidong; Lin, Zongtao; Chen, Shizhong

    2018-01-01

    In this study, an on-line supercritical fluid extraction (SFE) and supercritical fluid chromatography (SFC) method was developed for the rapid determination of oleanoic acid and ursolic acid in Chaenomelis Fructus. After optimization of the conditions, the two triterpenoid acids was obtained by SFE using 20% methanol as a modifier at 35°C in 8 min. They were resolved on a Shim-pack UC-X Diol column (4.6 × 150 mm, 3 μm) in 14 min (0 - 10 min, 5 - 10%; 10 - 14 min, 10% methanol in CO 2 ) with a backpressure of 15 MPa at 40°C. The on-line SFE-SFC method could be completed within 40 min (10.79 mg/g dry plant, R s = 2.36), while the ultrasound-assisted extraction and HPLC method required at least 90 min (3.55 mg/g dry plant, R s = 1.92). This on-line SFE-SFC method is powerful to simplify the pre-processing and quantitative analysis of natural products.

  19. An on-line coupling of nanofibrous extraction with column-switching high performance liquid chromatography - A case study on the determination of bisphenol A in environmental water samples.

    Science.gov (United States)

    Háková, Martina; Chocholoušová Havlíková, Lucie; Chvojka, Jiří; Solich, Petr; Šatínský, Dalibor

    2018-02-01

    Polyamide 6 nanofiber polymers were used as modern sorbents for on-line solid phase extraction (SPE) coupled with liquid chromatography. The on-line SPE system was tested for the determination of bisphenol A in river water samples. Polyamide nanofibers were prepared using needleless electrospinning, inserted into a mini-column cartridge (5 × 4.6mm) and coupled with HPLC. The effect of column packing and the amount of polyamide 6 on extraction efficiency was tested and the packing process was optimized. The proposed method was performed using a 50-µL sample injection followed by an on-line nanofibrous extraction procedure. The influence of the washing mobile phase on the retention of bisphenol A during the extraction procedure was evaluated. Ascentis ® Express C18 (10cm × 4.6mm) core-shell column was used as an analytical column. Fluorescence detection wavelengths (λ ex = 225nm and λ em = 320nm) were used for identification and quantification of Bisphenol A in river waters. The linearity was tested in the range from 2 to 500µgL -1 (using nine calibration points). The limits of detection and quantification were 0.6 and 2µgL -1 , respectively. The developed method was successfully used for the determination of bisphenol A in various samples of river waters in the Czech Republic (The Ohře, Labe, Nisa, Úpa, and Opava Rivers). Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Dopant-assisted negative photoionization Ion mobility spectrometry coupled with on-line cooling inlet for real-time monitoring H2S concentration in sewer gas.

    Science.gov (United States)

    Peng, Liying; Jiang, Dandan; Wang, Zhenxin; Hua, Lei; Li, Haiyang

    2016-06-01

    Malodorous hydrogen sulfide (H2S) gas often exists in the sewer system and associates with the problems of releasing the dangerous odor to the atmosphere and causing sewer pipe to be corroded. A simple method is in demand for real-time measuring H2S level in the sewer gas. In this paper, an innovated method based on dopant-assisted negative photoionization ion mobility spectrometry (DANP-IMS) with on-line semiconductor cooling inlet was put forward and successfully applied for the real-time measurement of H2S in sewer gas. The influence of moisture was effectively reduced via an on-line cooling method and a non-equilibrium dilution with drift gas. The limits of quantitation for the H2S in ≥60% relative humidity air could be obtained at ≤79.0ng L(-1) with linear ranges of 129-2064ng L(-1). The H2S concentration in a sewer manhole was successfully determined while its product ions were identified by an ion-mobility time-of-fight mass spectrometry. Finally, the correlation between sewer H2S concentration and the daily routines and habits of residents was investigated through hourly or real-time monitoring the variation of sewer H2S in manholes, indicating the power of this DANP-IMS method in assessing the H2S concentration in sewer system. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. On-line solid-phase extraction coupled to liquid chromatography tandem mass spectrometry for the analysis of cyanotoxins in algal blooms.

    Science.gov (United States)

    Fayad, Paul B; Roy-Lachapelle, Audrey; Duy, Sung Vo; Prévost, Michèle; Sauvé, Sébastien

    2015-12-15

    An analytical method based on on-line SPE-LC-HESI-MS/MS has been developed for the detection and quantification of eight selected cyanotoxins in algal bloom waters that include mycrocystins, anatoxin-a and cylindrospermopsin. The injection volume was 2 mL according to the expected concentration of cyanotoxins in matrix. The method provides an analysis time of 7 min per sample, acceptable recovery values (91-101%), good precision (RSD cyanotoxins. All of the targeted cyanotoxins were detected with the exception of cylindrospermopsin. In addition, it was found that total microcystin concentrations in several surface water samples exceeded the proposed guidelines established by the province of Québec in Canada of 1.5 μg L(-1) as well as the World Health Organization of 1 μg L(-1) for both free and cell-bound microcystin-LR equivalent. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Determination of etoricoxib in human plasma using automated on-line solid-phase extraction coupled with LC-APCI/MS/MS

    Directory of Open Access Journals (Sweden)

    Sérgio Luiz Dalmora

    2008-01-01

    Full Text Available A liquid chromatography-tandem mass spectrometry method with atmospheric pressure chemical ionization (LC-APCI/MS/MS was validated for the determination of etoricoxib in human plasma using antipyrin as internal standard, followed by on-line solid-phase extraction. The method was performed on a Luna C18 column and the mobile phase consisted of acetonitrile:water (95:5, v/v/ammonium acetate (pH 4.0; 10 mM, run at a flow rate of 0.6 mL/min. The method was linear in the range of 1-5000 ng/mL (r²>0.99. The lower limit of quantitation was 1 ng/mL. The recoveries were within 93.72-96.18%. Moreover, method validation demonstrated acceptable results for the precision, accuracy and stability studies.

  3. A on-line method for the determination of lead and lead isotope ratios in fresh and saline waters by inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Halicz, Ludwik; Lam, J.W.H.; McLaren, J.W.

    1994-01-01

    A previously reported on-line ICP-MS method for the determination of lead and other trace elements in seawater has been re-examined to determine its suitability for the determination of lead isotope ratios ( 206 Pb/ 207 Pb and 207 Pb/ 208 Pb) in fresh and saline natural waters. A detection limit of 0.9 ng/1 for total lead (for a 5 ml sample) was achieved. Precision of isotope ratio data was 0.2-0.3% RSD at a Pb concentration of 1 μg/l, and was still better than 2% at concentrations of only 10-40 ng/1 in seawater certified reference materials (CRMs). For all three natural water CRMs examined, measured precision was very close to the limit predicted by counting statistics. (Author)

  4. Acquisition of data from on-line laser turbidimeter and calculation of some kinetic variables in computer-coupled automated fed-batch culture

    International Nuclear Information System (INIS)

    Kadotani, Y.; Miyamoto, K.; Mishima, N.; Kominami, M.; Yamane, T.

    1995-01-01

    Output signals of a commercially available on-line laser turbidimeter exhibit fluctuations due to air and/or CO 2 bubbles. A simple data processing algorithm and a personal computer software have been developed to smooth the noisy turbidity data acquired, and to utilize them for the on-line calculations of some kinetic variables involved in batch and fed-batch cultures of uniformly dispersed microorganisms. With this software, about 10 3 instantaneous turbidity data acquired over 55 s are averaged and convert it to dry cell concentration, X, every minute. Also, volume of the culture broth, V, is estimated from the averaged output data of weight loss of feed solution reservoir, W, using an electronic balance on which the reservoir is placed. Then, the computer software is used to perform linear regression analyses over the past 30 min of the total biomass, VX, the natural logarithm of the total biomass, ln(VX), and the weight loss, W, in order to calculate volumetric growth rate, d(VX)/dt, specific growth rate, μ [ = dln(VX)/dt] and the rate of W, dW/dt, every minute in a fed-batch culture. The software used to perform the first-order regression analyses of VX, ln(VX) and W was applied to batch or fed-batch cultures of Escherichia coli on minimum synthetic or natural complex media. Sample determination coefficients of the three different variables (VX, ln(VX) and W) were close to unity, indicating that the calculations are accurate. Furthermore, growth yield, Y x/s , and specific substrate consumption rate, q sc , were approximately estimated from the data, dW/dt and in a ‘balanced’ fed-batch culture of E. coli on the minimum synthetic medium where the computer-aided substrate-feeding system automatically matches well with the cell growth. (author)

  5. On-line complexation/cloud point preconcentration for the sensitive determination of dysprosium in urine by flow injection inductively coupled plasma-optical emission spectrometry

    International Nuclear Information System (INIS)

    Ortega, Claudia; Cerutti, Soledad; Silva, Maria F.; Olsina, Roberto A.; Martinez, Luis D.

    2003-01-01

    An on-line dysprosium preconcentration and determination system based on the hyphenation of cloud point extraction (CPE) to flow injection analysis (FIA) associated with ICP-OES was studied. For the preconcentration of dysprosium, a Dy(III)-2-(5-bromo-2-pyridylazo)-5-diethylaminophenol complex was formed on-line at pH 9.22 in the presence of nonionic micelles of PONPE-7.5. The micellar system containing the complex was thermostated at 30 C in order to promote phase separation, and the surfactant-rich phase was retained in a microcolumn packed with cotton at pH 9.2. The surfactant-rich phase was eluted with 4 mol L -1 nitric acid at a flow rate of 1.5 mL min -1 , directly in the nebulizer of the plasma. An enhancement factor of 50 was obtained for the preconcentration of 50 mL of sample solution. The detection limit value for the preconcentration of 50 mL of aqueous solution of Dy was 0.03 μg L -1 . The precision for 10 replicate determinations at the 2.0 μg L -1 Dy level was 2.2% relative standard deviation (RSD), calculated from the peak heights obtained. The calibration graph using the preconcentration system for dysprosium was linear with a correlation coefficient of 0.9994 at levels near the detection limits up to at least 100 μg L -1 . The method was successfully applied to the determination of dysprosium in urine. (orig.)

  6. High-performance liquid chromatographic separation of biologically important arsenic species utilizing on-line inductively coupled argon plasma atomic emission spectrometric detection

    Energy Technology Data Exchange (ETDEWEB)

    Spall, W.D.; Lynn, J.G.; Andersen, J.L.; Valdez, J.G.; Gurley, L.R.

    1986-06-01

    An anion exchange, high-performance liquid chromatography technique using a 15-min linear gradient from water to 0.5 M ammonium carbonate to separate arsenite, arsenate, methylarsonic acid, and dimethylarsinic acid from neutral arsenic containing compounds was developed for application to a study of arsenic metabolism in cultured cell suspensions. Arsenic detection was accomplished by the direct coupling of the column effluent to an inductively coupled argon plasma atomic emission spectrometer (ICAP-AES) set to monitor the arsenic emission line at 197.19 nm. The analysis requires 20 min and is sensitive to as low as 60 ng of arsenic injected to the column.

  7. Evaluation of operational on-line-coupled regional air quality models over Europe and North America in the context of AQMEII phase 2. Part I: Ozone

    NARCIS (Netherlands)

    Im, U.; Bianconi, R.; Solazzo, E.; Kioutsioukis, I.; Badia, A.; Balzarini, A.; Baró, R.; Bellasio, R.; Brunner, D.; Chemel, C.; Curci, G.; Flemming, J.; Forkel, R.; Giordano, L.; Jiménez-Guerrero, P.; Hirtl, M.; Hodzic, A.; Honzak, L.; Jorba, O.; Knote, C.; Kuenen, J.J.P.; Makar, P.A.; Manders-Groot, A.; Neal, L.; Pérez, J.L.; Pirovano, G.; Pouliot, G.; San Jose, R.; Savage, N.; Schroder, W.; Sokhi, R.S.; Syrakov, D.; Torian, A.; Tuccella, P.; Werhahn, J.; Wolke, R.; Yahya, K.; Zabkar, R.; Zhang, Y.; Zhang, J.; Hogrefe, C.; Galmarini, S.

    2015-01-01

    The second phase of the Air Quality Model Evaluation International Initiative (AQMEII) brought together sixteen modeling groups from Europe and North America, running eight operational online-coupled air quality models over Europe and North America on common emissions and boundary conditions. With

  8. Development of a simple extraction cell with bi-directional continuous flow coupled on-line to ICP-MS for assessment of elemental associations in solid samples

    DEFF Research Database (Denmark)

    Buanuam, Janya; Tiptanasup, Kasipa; Shiowatana, Juwadee

    2006-01-01

    A continuous-flow system comprising a novel, custom-built extraction module and hyphenated with inductively coupled plasma-mass spectrometric (ICP-MS) detection is proposed for assessing metal mobilities and geochemical associations in soil compartments as based on using the three step BCR (now...... the Measurements and Testing Programme of the European Commission) sequential extraction scheme. Employing a peristaltic pump as liquid driver, alternate directional flows of the extractants are used to overcome compression of the solid particles within the extraction unit to ensure a steady partitioning flow rate...... and thus to maintain constant operationally defined extraction conditions. The proposed flow set-up is proven to allow for trouble-free handling of soil samples up to 1 g and flow rates ≤ 10 mL min–1. The miniaturized extraction system was coupled to ICP-MS through a flow injection interface in order...

  9. Liquid chromatography coupled to on-line post column derivatization for the determination of organic compounds: A review on instrumentation and chemistries

    International Nuclear Information System (INIS)

    Zacharis, Constantinos K.; Tzanavaras, Paraskevas D.

    2013-01-01

    Graphical abstract: -- Highlights: •Review on liquid chromatography coupled to post-column derivatization. •Overview of instrumentation for post-column derivatization. •Post-column chemistries for analysis of organic compounds. -- Abstract: Analytical derivatization either in pre or post column modes is one of the most widely used sample pretreatment techniques coupled to liquid chromatography. In the present review article we selected to discuss the post column derivatization mode for the analysis of organic compounds. The first part of the review focuses to the instrumentation of post-column setups including not only fundamental components such as pumps and reactors but also less common parts such as static mixers and back-pressure regulators; the second part of the article discusses the most popular “chemistries” that are involved in post column applications, including reagent-less approaches and new sensing platforms such as the popular gold nanoparticles. Some representative recent applications are also presented as tables

  10. Liquid chromatography coupled to on-line post column derivatization for the determination of organic compounds: A review on instrumentation and chemistries

    Energy Technology Data Exchange (ETDEWEB)

    Zacharis, Constantinos K., E-mail: zacharis@chem.auth.gr [Laboratory of Analytical Chemistry, Department of Chemistry, Aristotelian University of Thessaloniki, GR-54124 Thessaloniki (Greece); Department of Food Technology, School of Food Technology and Nutrition, Alexander Technological Educational Institute (ATEI) of Thessaloniki, 57400 Thessaloniki (Greece); Tzanavaras, Paraskevas D., E-mail: ptzanava@chem.auth.gr [Laboratory of Analytical Chemistry, Department of Chemistry, Aristotelian University of Thessaloniki, GR-54124 Thessaloniki (Greece)

    2013-10-10

    Graphical abstract: -- Highlights: •Review on liquid chromatography coupled to post-column derivatization. •Overview of instrumentation for post-column derivatization. •Post-column chemistries for analysis of organic compounds. -- Abstract: Analytical derivatization either in pre or post column modes is one of the most widely used sample pretreatment techniques coupled to liquid chromatography. In the present review article we selected to discuss the post column derivatization mode for the analysis of organic compounds. The first part of the review focuses to the instrumentation of post-column setups including not only fundamental components such as pumps and reactors but also less common parts such as static mixers and back-pressure regulators; the second part of the article discusses the most popular “chemistries” that are involved in post column applications, including reagent-less approaches and new sensing platforms such as the popular gold nanoparticles. Some representative recent applications are also presented as tables.

  11. Irreducible coupling between physical and biological phenomena: overview of on-line and off-line physical measurements during high cell density cultures of yarrowia lipolytica

    OpenAIRE

    Kraiem, Hazar; Manon, Yannick; Anne-Archard, Dominique; Fillaudeau, Luc

    2012-01-01

    During cell cultures in bioreactor, micro-organism physiology closely interacts with physico-chemical parameters (gas and feed flow rates, mixing, temperature, pH, pressure). The specificity of microbial bioreactions in relation with irreducible couplings between heat and mass transfers and fluid mechanics, led into complex (three phases medium) and dynamic (auto-biocatalytic reaction) systems. Our scientific approach aims to investigate, understand and control dynamic interactions between ph...

  12. Accelerated solvent extraction followed by on-line solid-phase extraction coupled to ion trap LC/MS/MS for analysis of benzalkonium chlorides in sediment samples

    Science.gov (United States)

    Ferrer, I.; Furlong, E.T.

    2002-01-01

    Benzalkonium chlorides (BACs) were successfully extracted from sediment samples using a new methodology based on accelerated solvent extraction (ASE) followed by an on-line cleanup step. The BACs were detected by liquid chromatography/ion trap mass spectrometry (LC/MS) or tandem mass spectrometry (MS/MS) using an electrospray interface operated in the positive ion mode. This methodology combines the high efficiency of extraction provided by a pressurized fluid and the high sensitivity offered by the ion trap MS/MS. The effects of solvent type and ASE operational variables, such as temperature and pressure, were evaluated. After optimization, a mixture of acetonitrile/water (6:4 or 7:3) was found to be most efficient for extracting BACs from the sediment samples. Extraction recoveries ranged from 95 to 105% for C12 and C14 homologues, respectively. Total method recoveries from fortified sediment samples, using a cleanup step followed by ASE, were 85% for C12BAC and 79% for C14-BAC. The methodology developed in this work provides detection limits in the subnanogram per gram range. Concentrations of BAC homologues ranged from 22 to 206 ??g/kg in sediment samples from different river sites downstream from wastewater treatment plants. The high affinity of BACs for soil suggests that BACs preferentially concentrate in sediment rather than in water.

  13. On-line coupling of a miniaturized bioreactor with capillary electrophoresis, via a membrane interface, for monitoring the production of organic acids by microorganisms.

    Science.gov (United States)

    Ehala, S; Vassiljeva, I; Kuldvee, R; Vilu, R; Kaljurand, M

    2001-09-01

    Capillary electrophoresis (CE) can be a valuable tool for on-line monitoring of bioprocesses. Production of organic acids by phosphorus-solubilizing bacteria and fermentation of UHT milk were monitored and controlled by use of a membrane-interfaced dialysis device and a home-made microsampler for a capillary electrophoresis unit. Use of this specially designed sampling device enabled rapid consecutive injections without interruption of the high voltage. No additional sample preparation was required. The time resolution of monitoring in this particular work was approximately 2 h, but could be reduced to 2 min. Analytes were detected at low microg mL(-1) levels with a reproducibility of approximately 10%. To demonstrate the potential of CE in processes of biotechnological interest, results from monitoring phosphate solubilization by bacteria were submitted to qualitative and quantitative analysis. Fermentation experiments on UHT milk showed that monitoring of the processes by CE can provide good resolution of complex mixtures, although for more specific, detailed characterization the identification of individual substances is needed.

  14. On-line micro-volume introduction system developed for lower density than water extraction solvent and dispersive liquid–liquid microextraction coupled with flame atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Anthemidis, Aristidis N.; Mitani, Constantina; Balkatzopoulou, Paschalia; Tzanavaras, Paraskevas D.

    2012-01-01

    Highlights: ► A dispersive liquid–liquid micro extraction method for lead and copper determination. ► A micro-volume transportation system for extractant solvent lighter than water. ► Analysis of natural water samples. - Abstract: A simple and fast preconcentration/separation dispersive liquid–liquid micro extraction (DLLME) method for metal determination based on the use of extraction solvent with lower density than water has been developed. For this purpose a novel micro-volume introduction system was developed enabling the on-line injection of the organic solvent into flame atomic absorption spectrometry (FAAS). The effectiveness and efficiency of the proposed system were demonstrated for lead and copper preconcentration in environmental water samples using di-isobutyl ketone (DBIK) as extraction solvent. Under the optimum conditions the enhancement factor for lead and copper was 187 and 310 respectively. For a sample volume of 10 mL, the detection limit (3 s) and the relative standard deviation were 1.2 μg L −1 and 3.3% for lead and 0.12 μg L −1 and 2.9% for copper respectively. The developed method was evaluated by analyzing certified reference material and it was applied successfully to the analysis of environmental water samples.

  15. Sb(III) and Sb(V) separation and analytical speciation by a continuous tandem on-line separation device in connection with inductively coupled plasma atomic emission spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Menendez Garcia, A. [Oviedo Univ. (Spain). Dept. of Phys. and Anal. Chem.; Perez Rodriguez, M.C. [Oviedo Univ. (Spain). Dept. of Phys. and Anal. Chem.; Sanchez Uria, J.F. [Oviedo Univ. (Spain). Dept. of Phys. and Anal. Chem.; Sanz-Medel, A. [Oviedo Univ. (Spain). Dept. of Phys. and Anal. Chem.

    1995-09-01

    A sensitive, precise and automated non-chromatographic method for Sb(III) and Sb(V) analytical speciation based on a continuous tandem on-line separation device in connection with inductively coupled plasma-atomic emission (ICP-AES) detection is proposed. Two on-line successive separation steps are included into this method: a continuous liquid-liquid extraction of Sb(III) with ammonium pyrrolidine dithiocarbamate (APDC) into methylisobuthylketone (MIBK), followed by direct stibine generation from the organic phase. Both separation steps are carried out in a continuous mode and on-line with the ICP-AES detector. Optimization of experimental conditions for the tandem separation and ICP-AES detection are investigated in detail. Detection limits for Sb(III) were 3 ng.mL{sup -1} and for Sb(V) 8 ng.mL{sup -1}. Precisions observed are in the range {+-} 5%. The proposed methodology has been applied to Sb(III) and Sb(V) speciation in sea-water samples. (orig.)

  16. Molecularly imprinted sol-gel nanofibers based solid phase microextraction coupled on-line with high performance liquid chromatography for selective determination of acesulfame.

    Science.gov (United States)

    Moein, Mohammad Mahdi; Javanbakht, Mehran; Karimi, Mohammad; Akbari-Adergani, Behrouz

    2015-03-01

    Sol-gel based molecularly imprinted polymer (MIP) nanofiber was successfully fabricated by electrospinning technique on the surface of a stainless steel bar. The manufactured tool was applied for on-line selective solid phase microextraction (SPME) and determination of acesulfame (ACF) as an artificial sweetener with high performance liquid chromatography (HPLC). The selective ability of method for the extraction of ACF was investigated in the presence of some selected sweeteners such as saccharine (SCH), aspartame (ASP) and caffeine (CAF). Electrospinning of MIP sol-gel solution on the stainless steel bar provided an unbreakable sorbent with high thermal, mechanical, and chemical stability. Moreover, application of the MIP-SPME tool revealed a unique approach for the selective microextraction of the analyte in beverage samples. In this work, 3-(triethoxysilyl)-propylamine (TMSPA) was chosen as a precursor due to its ability to imprint the analyte by hydrogen bonding, Van der Walls, and dipole-dipole interactions. Nylon 6 was also added as a backbone and support for the precursor in which sol could greatly growth during the sol-gel process and makes the solution electrospinable. Various effective parameters in the extraction efficiency of the MIP-SPME tool such as loading time, flow rate, desorption time, selectivity, and the sample volume were evaluated. The linearity for the ACF in beverage sample was in the range of 0.78-100.5 ng mL(-1). Limit of detection (LOD) and quantification (LOQ) were 0.23 and 0.78 ng mL(-1) respectively. The RSD values (n=5) were all below 3.5%at the 20 ng mL(-1) level. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. On-line coupling of a microelectrode array equipped poly(dimethylsiloxane) microchip with an integrated graphite electrospray emitter for electrospray ionisation mass spectrometry.

    Science.gov (United States)

    Liljegren, Gustav; Dahlin, Andreas; Zettersten, Camilla; Bergquist, Jonas; Nyholm, Leif

    2005-10-01

    A novel method for the manufacturing of microchips for on-chip combinations of electrochemistry (EC) and sheathless electrospray ionisation mass spectrometry (ESI-MS) is described. The technique, which does not require access to clean-room facilities, is based on the incorporation of an array of gold microcoil electrodes into a poly(dimethylsiloxane)(PDMS) microflow channel equipped with an integrated graphite based sheathless ESI emitter. Electrochemical measurements, which were employed to determine the electroactive area of the electrodes and to test the microchips, show that the manufacturing process was reproducible and that the important interelectrode distance in the electrochemical cell could to be adequately controlled. The EC-ESI-MS device was evaluated based on the ESI-MS detection of the oxidation products of dopamine. The results demonstrate that the present on-chip approach enables full potentiostatic control of the electrochemical cell and the attainment of very short transfer times between the electrochemical cell and the electrospray emitter. The transfer times were 0.6 and 1.2 s for flow rates of 1.0 and 0.5 microL min(-1), respectively, while the electrochemical conversion efficiency of the electrochemical cell was found to be 30% at a flow rate of 0.5 microL min(-1). To decouple the electrochemical cell from the ESI-MS high voltage and to increase the user-friendliness, the on-line electrochemistry-ESI-MS experiments were performed using a wireless Bluetooth battery-powered instrument with the chip floating at the potential induced by the ESI high voltage. The described on-chip EC-ESI-MS device can be used for fundamental electrochemical investigations as well as for applications based on the use of electrochemically controlled sample pretreatment, preconcentration and ionisation steps prior to ESI-MS.

  18. Analysis of particulate polycyclic aromatic hydrocarbons by on-line coupled supercritical fluid extraction-liquid chromatography-gas chromatography-mass spectrometry

    Science.gov (United States)

    Shimmo, Masahiko; Adler, Heidi; Hyötyläinen, Tuulia; Hartonen, Kari; Kulmala, Markku; Riekkola, Marja-Liisa

    An on-line supercritical fluid extraction-liquid chromatography-gas chromatography-mass spectrometry (SFE-LC-GC-MS) method was developed for the analysis of the particulate polycyclic aromatic hydrocarbons (PAHs). The limits of detection of the system for the quantification standards were in the range of 0.25-0.57 ng, while the limits of determinations for filter samples varied from 0.02 to 0.04 ng m -3 (24 h sampling). The linearity was excellent from 5 to 300 ng ( R2>0.967). The analysis could be carried out in a closed system without tedious manual sample pretreatment and with no risk of errors by contamination or loss of the analytes. The results of the SFE-LC-GC-MS method were comparable with those for Soxhlet and shake-flask extractions with GC-MS. The new method was applied to the analysis of PAHs collected by high-volume filter in the Helsinki area to study the seasonal trend of the concentrations. The individual PAH concentrations varied from 0.015 to more than 1 ng m -3, while total PAH concentrations varied from 0.81 to 5.68 ng m -3. The concentrations were generally higher in winter than in summer. The mass percentage of the total PAHs in total suspended particulates ranged from 2.85×10 -3% in July to 15.0×10 -3% in December. Increased emissions in winter, meteorological conditions, and more serious artefacts during the sampling in summer season may explain the concentration profiles.

  19. Development of a system for simultaneous - sequential determinations of major and minor actinides (Th, Np, U, Pu, Am, Cm) by on-line extraction chromatography - ion concentration - inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Trivellone, E.; Mariani, M.; Carlos-Marquez, R.; Aldave de las Heras, L.; Betti, M.; )

    2009-01-01

    Full text: Because of the great complexity and time consuming of traditional methods for actinides determination, a procedure for their simultaneous and sequential separation and quantification was developed. A complete circuit constituted by three analytical chromatographic columns packed with TEVA, UTEVA and TRU resins (Eichrom Inc) for retention of tetra-, hexa- and tri-valent actinides and three cation concentrator columns TCC-II (from Dionex Corporation) connected by six (4-way and 6-way) valves is coupled on-line to an ICPMS detector. The use of TCC-II columns just prior of the ICPMS determination allows to improve sensitivity and detection limits down to the ng/l level. The use of a coupled HPLC to an ICPMS system enables the complete analysis of all the six actinides in almost 2 hours. (author)

  20. Use of an Open Port Sampling Interface Coupled to Electrospray Ionization for the On-Line Analysis of Organic Aerosol Particles

    Science.gov (United States)

    Swanson, Kenneth D.; Worth, Anne L.; Glish, Gary L.

    2018-02-01

    A simple design for an open port sampling interface coupled to electrospray ionization (OPSI-ESI) is presented for the analysis of organic aerosols. The design uses minimal modifications to a Bruker electrospray (ESI) emitter to create a continuous flow, self-aspirating open port sampling interface. Considerations are presented for introducing aerosol to the open port sampling interface including aerosol gas flow and solvent flow rates. The device has been demonstrated for use with an aerosol of nicotine as well as aerosol formed in the pyrolysis of biomass. Upon comparison with extractive electrospray ionization (EESI), this device has similar sensitivity with increased reproducibility by nearly a factor of three. The device has the form factor of a standard Bruker/Agilent ESI emitter and can be used without any further instrument modifications.

  1. Improvements to the on-line mass separator, RAMA, and the beta-delayed charged-particle emission of proton-rich sd shell nuclei

    International Nuclear Information System (INIS)

    Ognibene, T.J.

    1996-03-01

    To overcome the extreme difficulties encountered in the experimental decay studies of proton drip line nuclei, several techniques have been utilized, including a helium-jet transport system, particle identification detectors and mass separation. Improvements to the ion source/extraction region of the He-jet coupled on-line Recoil Atom Mass Analyzer (RAMA) and its target/ion source coupling resulted in significant increases in RAMA efficiencies and its mass resolution, as well as reductions in the overall transit time. At the 88-Inch Cyclotron at LBNL, the decays of 31 Cl, 27 P and 28 P, with half-lives of 150 msec, 260 msec and 270.3 msec, respectively, were examined using a he-jet and low-energy gas ΔE-gas ΔE-silicon E detector telescopes. Total beta-delayed proton branches of 0.3% and 0.07% in 31 Cl and 27 P, respectively, were estimated. Several proton peaks that had been previously assigned to the decay of 31 Cl were shown to be from the decay of 25 Si. In 27 P, two proton groups at 459 ± 14 keV and 610 ± 11 keV, with intensities of 7 ± 3% and 92 ± 4% relative to the main (100%) group were discovered. The Gamow-Teller component of the preceding beta-decay of each observed proton transition was compared to results from shell model calculations. Finally, a new proton transition was identified, following the β-decay of 28 P, at 1,444 ± 12 keV with a 1.7 ± 0.5% relative intensity to the 100% group. Using similar low-energy detector telescopes and the mass separator TISOL at TRIUMF, the 109 msec and 173 msec activities, 17 Ne and 33 Ar, were studied. A new proton group with energy 729 ± 15 keV was observed following the beta-decay of 17 Ne. Several discrepancies between earlier works as to the energies, intensities and assignments of several proton transitions from 17 Ne and 33 Ar were resolved

  2. Determination of lead by hydride generation inductively coupled plasma mass spectrometry (HG-ICP-MS): On-line generation of plumbane using potassium hexacyanomanganate(III)

    Energy Technology Data Exchange (ETDEWEB)

    Yilmaz, Vedat [Jackson State University, Department of Chemistry and Biochemistry, Jackson, MS 39217 (United States); Erciyes University, Faculty of Pharmacy, Department of Analytical Chemistry, 38039 Kayseri (Turkey); Arslan, Zikri, E-mail: zikri.arslan@jsums.edu [Jackson State University, Department of Chemistry and Biochemistry, Jackson, MS 39217 (United States); Rose, LaKeysha [Jackson State University, Department of Chemistry and Biochemistry, Jackson, MS 39217 (United States)

    2013-01-25

    Highlights: Black-Right-Pointing-Pointer Potassium hexacyanomanganate(III), (K{sub 3}Mn(CN){sub 6}, was utilized first time for hydride generation (HG). Black-Right-Pointing-Pointer Hexacyanomanganate(III) promoted generation of lead hydride (PbH{sub 4}) remarkably. Black-Right-Pointing-Pointer The HG method using K{sub 3}Mn(CN){sub 6} enhanced sensitivity by at least 40-fold. Black-Right-Pointing-Pointer The method detection limits for Pb were as low as 8 ng L{sup -1} by ICP-MS. Black-Right-Pointing-Pointer The method is highly suitable for quantitative determination of Pb in various samples and salt matrices by ICP-MS. - Abstract: A hydride generation (HG) procedure has been described for determination of Pb by ICP-MS using potassium hexacyanomanganate(III), K{sub 3}Mn(CN){sub 6}, as an additive to facilitate the generation of plumbane (PbH{sub 4}). Potassium hexacyanomanganate(III) was prepared in acidic medium as it was unstable in water. The stability of hexacyanomanganate(III) was examined in dilute solutions of HCl, HNO{sub 3} and H{sub 2}SO{sub 4}. The solutions prepared in 1% v/v H{sub 2}SO{sub 4} were found to be stable for over a period of 24 h. The least suitable medium was 1% v/v HNO{sub 3}. For generation of plumbane, acidic hexacyanomanganate(III) and sample solutions were mixed on-line along a 5-cm long tygon tubing (1.14 mm i.d.) and then reacted with 2% m/v sodium borohydride (NaBH{sub 4}). A concentration of 0.5% m/v K{sub 3}Mn(CN){sub 6} facilitated the generation of PbH{sub 4} remarkably. In comparison to H{sub 2}SO{sub 4}, HCl provided broader working range for which optimum concentration was 1% v/v. No significant interferences were noted from transition metals and hydride forming elements, up to 0.5 {mu}g mL{sup -1} levels, except Cu which depressed the signals severely. The depressive effects in the presence of 0.1 {mu}g mL{sup -1} Cu were alleviated by increasing the concentration of K{sub 3}Mn(CN){sub 6} to 2% m/v. Under these conditions

  3. Molecularly imprinted polymer cartridges coupled on-line with high performance liquid chromatography for simple and rapid analysis of dextromethorphan in human plasma samples.

    Science.gov (United States)

    Moein, Mohammad Mahdi; Javanbakht, Mehran; Akbari-Adergani, Behrouz

    2011-04-01

    In this paper, a novel method is described for automated determination of dextromethorphan in biological fluids using molecularly imprinted solid-phase extraction (MISPE) as a sample clean-up technique combined with high performance liquid chromatography (HPLC). The water-compatible molecularly imprinted polymers (MIPs) were prepared using methacrylic acid as functional monomer, ethylene glycol dimethacrylate as cross-linker, chloroform as porogen and dextromethorphan as template molecule. These imprinted polymers were used as solid-phase extraction sorbent for the extraction of dextromethorphan from human plasma samples. Various parameters affecting the extraction efficiency of the MIP cartridges were evaluated. The high selectivity of the sorbent coupled to the high performance liquid chromatographic system permitted a simple and rapid analysis of this drug in plasma samples with limits of detection (LOD) and quantification (LOQ) of 0.12 ng/mL and 0.35 ng/mL, respectively. The MIP selectivity was evaluated by analyzing of the dextromethorphan in presence of several substances with similar molecular structures and properties. Results from the HPLC analyses showed that the recoveries of dextromethorphan using MIP cartridges from human plasma samples in the range of 1-50 ng/mL were higher than 87%. Copyright © 2011 Elsevier B.V. All rights reserved.

  4. Application of cotton as a solid phase extraction sorbent for on-line preconcentration of copper in water samples prior to inductively coupled plasma optical emission spectrometry determination.

    Science.gov (United States)

    Faraji, Mohammad; Yamini, Yadollah; Shariati, Shahab

    2009-07-30

    Copper, as a heavy metal, is toxic for many biological systems. Thus, the determination of trace amounts of copper in environmental samples is of great importance. In the present work, a new method was developed for the determination of trace amounts of copper in water samples. The method is based on the formation of ternary Cu(II)-CAS-CTAB ion-pair and adsorption of it into a mini-column packed with cotton prior applying inductively coupled plasma optical emission spectrometry (ICP-OES). The experimental parameters that affected the extraction efficiency of the method such as pH, flow rate and volume of the sample solution, concentration of chromazurol S (CAS) and cethyltrimethylammonium bromide (CTAB) as well as type and concentration of eluent were investigated and optimized. The ion-pair (Cu(II)-CAS-CTAB) was quantitatively retained on the cotton under the optimum conditions, then eluted completely using a solution of 25% (v/v) 1-propanol in 0.5 mol L(-1) HNO(3) and directly introduced into the nebulizer of the ICP-OES. The detection limit (DL) of the method for copper was 40 ng L(-1) (V(sample)=100mL) and the relative standard deviation (R.S.D.) for the determination of copper at 10 microg L(-1) level was found to be 1.3%. The method was successfully applied to determine the trace amounts of copper in tap water, deep well water, seawater and two different mineral waters, and suitable recoveries were obtained (92-106%).

  5. Determination of tellurium at ultra-trace levels in drinking water by on-line solid phase extraction coupled to graphite furnace atomic absorption spectrometer

    International Nuclear Information System (INIS)

    Pedro, Juana; Stripekis, Jorge; Bonivardi, Adrian; Tudino, Mabel

    2008-01-01

    In this paper, two time-based flow injection (FI) separation pre-concentration systems coupled to graphite furnace atomic absorption spectrometry (GFAAS) for tellurium determination are studied and compared. The first alternative involves the pre-concentration of the analyte onto Dowex 1X8 employed as packaging material of a micro-column inserted in the flow system. The second set-up is based on the co-precipitation of tellurium with La(OH) 3 followed by retention onto XAD resins. Both systems are compared in terms of limit of detection, linear range, RSD%, sample throughput, micro-columns lifetime and aptitude for fully automatic operation. The features of the Dowex system are: 37% efficiency of retention and an enhancement factor of 42 for a pre-concentration time of 180 seconds (sample flow rate = 3 ml min -1 ) with acetic acid elution volumes of 80 μl. The detection limit (3 s) is 7 ng l -1 and the relative standard deviation (n = 7200 ng l -1 ) is 5.8%. The analytical performance of the XAD system is: 72% efficiency of retention and an enhancement factor of 25 for a pre-concentration time of 180 s (sample flow rate = 3 ml min -1 ) with nitric acid elution volumes of 300 μl. The detection limit is 66 ng l -1 and the relative standard deviation (n = 7200 ng l -1 ) is 8.3%. Applications to the determination of tellurium in tap water and the validation of the analytical methodology employing SRM 1643e as certified reference material are shown

  6. Development of an on-line flow injection Sr/matrix separation method for accurate, high-throughput determination of Sr isotope ratios by multiple collector-inductively coupled plasma-mass spectrometry.

    Science.gov (United States)

    Galler, Patrick; Limbeck, Andreas; Boulyga, Sergei F; Stingeder, Gerhard; Hirata, Takafumi; Prohaska, Thomas

    2007-07-01

    This work introduces a newly developed on-line flow injection (FI) Sr/Rb separation method as an alternative to the common, manual Sr/matrix batch separation procedure, since total analysis time is often limited by sample preparation despite the fast rate of data acquisition possible by inductively coupled plasma-mass spectrometers (ICPMS). Separation columns containing approximately 100 muL of Sr-specific resin were used for on-line FI Sr/matrix separation with subsequent determination of (87)Sr/(86)Sr isotope ratios by multiple collector ICPMS. The occurrence of memory effects exhibited by the Sr-specific resin, a major restriction to the repetitive use of this costly material, could successfully be overcome. The method was fully validated by means of certified reference materials. A set of two biological and six geological Sr- and Rb-bearing samples was successfully characterized for its (87)Sr/(86)Sr isotope ratios with precisions of 0.01-0.04% 2 RSD (n = 5-10). Based on our measurements we suggest (87)Sr/(86)Sr isotope ratios of 0.713 15 +/- 0.000 16 (2 SD) and 0.709 31 +/- 0.000 06 (2 SD) for the NIST SRM 1400 bone ash and the NIST SRM 1486 bone meal, respectively. Measured (87)Sr/(86)Sr isotope ratios for five basalt samples are in excellent agreement with published data with deviations from the published value ranging from 0 to 0.03%. A mica sample with a Rb/Sr ratio of approximately 1 was successfully characterized for its (87)Sr/(86)Sr isotope signature to be 0.718 24 +/- 0.000 29 (2 SD) by the proposed method. Synthetic samples with Rb/Sr ratios of up to 10/1 could successfully be measured without significant interferences on mass 87, which would otherwise bias the accuracy and uncertainty of the obtained data.

  7. Analysis of biogenic carbonates by inductively coupled plasma-mass spectrometry (ICP-MS). Flow injection on-line solid-phase preconcentration for trace element determination in fish otoliths.

    Science.gov (United States)

    Arslan, Z; Paulson, A J

    2002-04-01

    The aragonite deposits within the ear bones (otoliths) of teleost fish retain a chemical signal reflecting the life history of fish (similar to rings of trees) and the nature of fish habitats. Otoliths dissolved in acid solutions contain high concentrations of calcium and a variety of proteins. Elimination of matrix salts and organic interferences during preconcentration is essential for accurate determination of trace elements in otolith solutions by inductively coupled plasma-quadrupole mass spectrometry. An iminodiacetate-based chelating resin (Toyopearl AF-Chelate 650 M) has been used for on-line preconcentration and matrix separation for the determination of 31 transition and rare elements. Successful preconcentration of the elements was achieved at pH 5 by on-line buffering, except Mn which required pH 8.8. Sample solutions were loaded on to the column for 1 min at 3.2 mL min(-1), and then eluted directly into the mass spectrometer with 4% v/v nitric acid. This procedure enabled up to 25-fold preconcentration with successful removal of the calcium matrix. The effect of heat-assisted oxidation with concentrated nitric acid was investigated to eliminate the organic matrix. It was found that heating to dryness after dissolution and further mineralization with the acid significantly improved the retention of the transition elements. The method was validated by analysis of a certified reference material produced from saggittal otoliths of emperor snapper ( Lutjanus sebae), and then applied to the determination of trace metal concentrations in juvenile bluefin tuna ( Thunnus thynnus) from the Western Pacific Ocean.

  8. Metal-organic framework MIL-101 as sorbent based on double-pumps controlled on-line solid-phase extraction coupled with high-performance liquid chromatography for the determination of flavonoids in environmental water samples.

    Science.gov (United States)

    Liu, Yue; Hu, Jia; Li, Yan; Li, Xiao-Shuang; Wang, Zhong-Liang

    2016-10-01

    A novel method with high sensitivity for the rapid determination of chrysin, apigenin and luteolin in environment water samples was developed by double-pumps controlled on-line solid-phase extraction (SPE) coupled with high-performance liquid chromatography (HPLC). In the developed technique, metal organic framework MIL-101 was synthesized and applied as a sorbent for SPE. The as-synthesized MIL-101 was characterized by scanning electron microscope, X-ray diffraction spectrometry, thermal gravimetric analysis and micropore physisorption analysis. The MIL-101 behaved as a fast kinetics in the adsorption of chrysin, apigenin and luteolin. On-line SPE of chrysin, apigenin and luteolin was processed by loading a sample solution at a flow rate of 1.0 mL/min for 10 min. The extracted analytes were subsequently eluted into a ZORBAX Bonus-RP analytical column (25 cm long × 4.6 mm i.d.) for HPLC separation under isocratic condition with a mobile phase (MeOH: ACN: 0.02 M H 3 PO 4 = 35:35:30) at a flow rate of 1.0 mL/min. Experimental conditions, including ionic strength, sample pH, sample loading rates, sample loading time and desorption analytes time, were further optimized to obtain efficient preconcentration and high-precision determination of the analytes mentioned above. The method achieved the merits of simplicity, rapidity, sensitivity, wide linear range and high sample throughput. The possible mechanism for the adsorption of flavonoids on MIL-101 was proposed. The developed method has been applied to determine trace chrysin, apigenin and luteolin in a variety of environmental water samples. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Trace analysis of three antihistamines in human urine by on-line single drop liquid-liquid-liquid microextraction coupled to sweeping micellar electrokinetic chromatography and its application to pharmacokinetic study.

    Science.gov (United States)

    Gao, Wenhua; Chen, Yunsheng; Chen, Gaopan; Xi, Jing; Chen, Yaowen; Yang, Jianying; Xu, Ning

    2012-09-01

    A rapid and efficient dual preconcentration method of on-line single drop liquid-liquid-liquid microextraction (SD-LLLME) coupled to sweeping micellar electrokinetic chromatography (MEKC) was developed for trace analysis of three antihistamines (mizolastine, chlorpheniramine and pheniramine) in human urine. Three analytes were firstly extracted from donor phase (4 mL urine sample) adjusted to alkaline condition (0.5 M NaOH). The unionized analytes were subsequently extracted into a drop of n-octanol layered over the urine sample, and then into a microdrop of acceptor phase (100 mM H(3)PO(4)) suspended from a capillary inlet. The enriched acceptor phase was on-line injected into capillary with a height difference and then analyzed directly by sweeping MEKC. Good linear relationships were obtained for all analytes in a range of 6.25 × 10(-6) to 2.5 × 10(-4)g/L with correlation coefficients (r) higher than 0.987. The proposed method achieved limits of detections (LOD) varied from 1.2 × 10(-7) to 9.5 × 10(-7)g/L based on a signal-to-noise of 3 (S/N=3) with 751- to 1372-fold increases in detection sensitivity for analytes, and it was successfully applied to the pharmacokinetic study of three antihistamines in human urine after an oral administration. The results demonstrated that this method was a promising combination for the rapid trace analysis of antihistamines in human urine with the advantages of operation simplicity, high enrichment factor and little solvent consumption. Copyright © 2012 Elsevier B.V. All rights reserved.

  10. Simple and quick determination of analgesics and other contaminants of emerging concern in environmental waters by on-line solid phase extraction coupled to liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Ferrer-Aguirre, Alejandra; Romero-González, Roberto; Vidal, J L Martínez; Frenich, Antonia Garrido

    2016-05-13

    A simple and quick analytical method has been developed for the determination of pharmaceutical compounds in water. An on-line solid-phase extraction (SPE) coupled to liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been optimized to determine 7 contaminants of emerging concern in environmental waters at ngL(-1) levels. This procedure requires minimal sample handling and small sample volume (900μL) with a total running time of 18min. Several SPE parameters were evaluated and optimized in order to achieve a high sample throughput. Therefore sample volume, carryover and reusability of the cartridges were evaluated. Performance characteristics were evaluated and good linearity was obtained (R(2)>0.98). Recoveries were evaluated in spiked samples at three concentrations and the values ranged from 71 to 104%. Intra and inter-day precision was lower than 10 and 13% respectively. Limits of quantification were equal to or lower than 10ngL(-1), except for 1,7-dimethylxanthine (20ngL(-1)) and ibuprofen (50ngL(-1)). The method was applied to 20 environmental water samples, and ibuprofen was the compound most widely detected at concentrations up to 42.06μgL(-1), whereas the other compounds were detected in fewer samples at lower concentrations (up to 15.99μgL(-1)). Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Development of a method based on on-line reversed phase liquid chromatography and gas chromatography coupled by means of an adsorption-desorption interface for the analysis of selected chiral volatile compounds in methyl jasmonate treated strawberries.

    Science.gov (United States)

    de la Peña Moreno, Fernando; Blanch, Gracia Patricia; Flores, Gema; Ruiz Del Castillo, Maria Luisa

    2010-02-12

    A method based on the use of the through oven transfer adsorption-desorption (TOTAD) interface in on-line coupling between reversed phase liquid chromatography and gas chromatography (RPLC-GC) for the determination of chiral volatile compounds was developed. In particular, the method was applied to the study of the influence of methyl jasmonate (MJ) treatment on the production and enantiomeric composition of selected aroma compounds in strawberry. The compounds studied were ethyl 2-methylbutanoate, linalool and 4-hydroxy-2,5-dimethyl-3(2H)-furanone (i.e. furaneol), which were examined on days 3, 6 and 9 after treatment. The method developed resulted in relative standard deviations (RSDs) of 21.6%, 8.1% and 9.8% and limits of detection (LD) of 0.04, 0.07 and 0.02mg/l for ethyl 2-methylbutanoate, linalool and furaneol, respectively. The application of the RPLC-TOTAD-GC method allowed higher levels of ethyl 2-methylbutanoate, linalool and furaneol to be detected, particularly after 9 days of treatment. Besides, MJ demonstrated to affect the enantiomeric distribution of ethyl 2-methylbutanoate. On the contrary, the enantiomeric composition of linalool and furaneol kept constant in both control and MJ-treated strawberries throughout the study. These results are discussed. Copyright 2009 Elsevier B.V. All rights reserved.

  12. On-line filtering

    International Nuclear Information System (INIS)

    Verkerk, C.

    1978-01-01

    Present day electronic detectors used in high energy physics make it possible to obtain high event rates and it is likely that future experiments will face even higher data rates than at present. The complexity of the apparatus increases very rapidly with time and also the criteria for selecting desired events become more and more complex. So complex in fact that the fast trigger system cannot be designed to fully cope with it. The interesting events become thus contaminated with multitudes of uninteresting ones. To distinguish the 'good' events from the often overwhelming background of other events one has to resort to computing techniques. Normally this selection is made in the first part of the analysis of the events, analysis normally performed on a powerful scientific computer. This implies however that many uninteresting or background events have to be recorded during the experiment for subsequent analysis. A number of undesired consequences result; and these constitute a sufficient reason for trying to perform the selection at an earlier stage, in fact ideally before the events are recorded on magnetic tape. This early selection is called 'on-line filtering' and it is the topic of the present lectures. (Auth.)

  13. On line portal imaging

    International Nuclear Information System (INIS)

    Munro, Peter

    1997-01-01

    Purpose/Objective: The purpose of this presentation is to examine the various imaging devices that have been developed for portal imaging, describe some of the image registration methods that have been developed to determine geometric errors quantitatively, and discuss how portal imaging has been incorporated into clinical practice. Discussion: Verification of patient positioning has always been an important aspect of external beam radiation therapy. Over the past decade many portal imaging devices have been developed by individual investigators and most accelerator manufacturers now offer 'on-line' portal imaging systems. The commercial devices include T.V. camera-based systems, liquid ionisation chamber systems, and shortly, flat panel systems. The characteristics of these imaging systems will be discussed. In addition, other approaches such as the use of kilovoltage x-ray sources, video monitoring, and ultrasound have been proposed for improving patient positioning. Some of the advantages of these approaches will be discussed. One of the major advantages of on-line portal imaging is that many quantitative techniques have been developed to detect errors in patient positioning. The general approach is to register anatomic structures on a portal image with the same structures on a digitized simulator film. Once the anatomic structures have been registered, any discrepancies in the position of the patient can be identified. One problem is finding a common frame of reference for the simulator and portal images, since the location of the radiation field within the pixel matrix may differ for the two images. As a result, a common frame of reference has to be established before the anatomic structures in the images can be registered - generally by registering radiation field edges identified in the simulator and portal images. In addition, distortions in patient geometry or rotations out of the image plane can confound the image registration techniques. Despite the

  14. On line portal imaging

    International Nuclear Information System (INIS)

    Munro, Peter

    1996-01-01

    Purpose/Objective: The purpose of this presentation is to examine the various imaging devices that have been developed for portal imaging; describe some of the image registration methods that have been developed to determine geometric errors quantitatively; discuss some of the ways that portal imaging has been incorporated into routine clinical practice; describe quality assurance procedures for these devices, and discuss the use of portal imaging devices for dosimetry applications. Discussion: Verification of patient positioning has always been an important aspect of external beam radiation therapy. Over the past decade many portal imaging devices have been developed by individual investigators and most accelerator manufacturers now offer 'on-line' portal imaging systems. The commercial devices can be classified into three categories: T.V. camera-based systems, liquid ionisation chamber systems, and amorphous silicon systems. Many factors influence the quality of images generated by these portal imaging systems. These include factors which are unavoidable (e.g., low subject contrast), factors which depend upon the individual imaging device forming the image (e.g., dose utilisation, spatial resolution) as well as factors which depend upon the characteristics of the linear accelerator irradiating the imaging system (x-ray source size, image magnification). The characteristics of individual imaging systems, such as spatial resolution, temporal response, and quantum utilisation will be discussed. One of the major advantages of on-line portal imaging is that many quantitative techniques have been developed to detect errors in patient positioning. The general approach is to register anatomic structures on a portal image with the same structures on a digitized simulator film. Once the anatomic structures have been registered, any discrepancies in the position of the patient can be identified. However, the task is not nearly as straight-forward as it sounds. One problem

  15. Development of a two-dimensional high-performance liquid chromatography system coupled with on-line reduction as a new efficient analytical method of 3-nitrobenzanthrone, a potential human carcinogen.

    Science.gov (United States)

    Hasei, Tomohiro; Nakanishi, Haruka; Toda, Yumiko; Watanabe, Tetsushi

    2012-08-31

    3-Nitrobenzanthrone (3-NBA) is an extremely strong mutagen and carcinogen in rats inducing squamous cell carcinoma and adenocarcinoma. We developed a new sensitive analytical method, a two-dimensional HPLC system coupled with on-line reduction, to quantify non-fluorescent 3-NBA as fluorescent 3-aminobenzanthrone (3-ABA). The two-dimensional HPLC system consisted of reversed-phase HPLC and normal-phase HPLC, which were connected with a switch valve. 3-NBA was purified by reversed-phase HPLC and reduced to 3-ABA with a catalyst column, packed with alumina coated with platinum, in ethanol. An alcoholic solvent is necessary for reduction of 3-NBA, but 3-ABA is not fluorescent in the alcoholic solvent. Therefore, 3-ABA was separated from alcohol and impurities by normal-phase HPLC and detected with a fluorescence detector. Extracts from surface soil, airborne particles, classified airborne particles, and incinerator dust were applied to the two-dimensional HPLC system after clean-up with a silica gel column. 3-NBA, detected as 3-ABA, in the extracts was found as a single peak on the chromatograms without any interfering peaks. 3-NBA was detected in 4 incinerator dust samples (n=5). When classified airborne particles, that is, those 7.0 μm in size, were applied to the two-dimensional HPLC system after purified using a silica gel column, 3-NBA was detected in those particles with particle sizes NBA in airborne particles and the detection of 3-NBA in incinerator dust. Copyright © 2012 Elsevier B.V. All rights reserved.

  16. Simultaneous multi-mycotoxin determination in nutmeg by ultrasound-assisted solid-liquid extraction and immunoaffinity column clean-up coupled with liquid chromatography and on-line post-column photochemical derivatization-fluorescence detection.

    Science.gov (United States)

    Kong, Wei-Jun; Liu, Shu-Yu; Qiu, Feng; Xiao, Xiao-He; Yang, Mei-Hua

    2013-05-07

    A simple and sensitive analytical method based on ultrasound-assisted solid-liquid extraction and immunoaffinity column clean-up coupled with high performance liquid chromatography and on-line post-column photochemical derivatization-fluorescence detection (USLE-IAC-HPLC-PCD-FLD) has been developed for simultaneous multi-mycotoxin determination of aflatoxins B1, B2, G1, G2 (AFB1, AFB2, AFG1, AFG2) and ochratoxin A (OTA) in 13 edible and medicinal nutmeg samples marketed in China. AFs and OTA were extracted from nutmeg samples by ultrasonication using a methanol : water (80 : 20, v/v) solution, followed by an IAC clean-up step. Different USL extraction conditions, pre-processing ways for nutmeg sample and clean-up columns for mycotoxins, as well as HPLC-PCD-FLD parameters (mobile phase, column temperature, elution procedure, excitation and emission wavelengths) were optimized. This method, which was appraised for analyzing nutmeg samples, showed satisfactory results with reference to limits of detection (LODs) (from 0.02 to 0.25 μg kg(-1)), limits of quantification (LOQs) (from 0.06 to 0.8 μg kg(-1)), linear ranges (up to 30 ng mL(-1) for AFB1, AFG1 and OTA and 9 ng mL(-1) for AFB2 and AFG2), intra- and inter-day variability (all application of developed method in nutmeg samples have elucidated that four samples were detected with contamination of AFs and one with OTA. AFB1 was the most frequently found mycotoxin in 30.8% of nutmeg samples at contamination levels of 0.73-16.31 μg kg(-1). At least two different mycotoxins were co-occurred in three samples, and three AFs were simultaneously detected in one sample.

  17. On line portal imaging

    International Nuclear Information System (INIS)

    Munro, Peter

    1995-01-01

    Purpose/Objective: The purpose of this presentation is to review the physics of imaging with high energy x-ray beams; examine the various imaging devices that have been developed for portal imaging; describe some of the image registration methods that have been developed to determine errors in patient positioning quantitatively; and discuss some of the ways that portal imaging has been incorporated into routine clinical practice. Verification of patient positioning has always been an important aspect of external beam radiation therapy. Checks of patient positioning have generally been done with film, however, film suffers from a number of drawbacks, such as poor image display and delays due to film development. Over the past decade many portal imaging devices have been developed by individual investigators and most accelerator manufacturers now offer 'on-line' portal imaging systems, which are intended to overcome the limitations of portal films. The commercial devices can be classified into three categories: T.V. camera-based systems, liquid ionisation chamber systems, and amorphous silicon systems. Many factors influence the quality of images generated by these portal imaging systems. These include factors which are unavoidable (e.g., low subject contrast), factors which depend upon the individual imaging device forming the image (e.g., dose utilisation, spatial resolution) as well as factors which depend upon the characteristics of the linear accelerator irradiating the imaging system (x-ray source size, image magnification). The fundamental factors which limit image quality and the characteristics of individual imaging systems, such as spatial resolution, temporal response, and quantum utilisation will be discussed. One of the major advantages of on-line portal imaging is that many quantitative techniques have been developed to detect errors in patient positioning. The general approach is to register anatomic structures on a portal image with the same

  18. Fast and simple screening for the simultaneous analysis of seven metabolites derived from five volatile organic compounds in human urine using on-line solid-phase extraction coupled with liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Chiang, Wen-Chieh; Chen, Chao-Yu; Lee, Ting-Chen; Lee, Hui-Ling; Lin, Yu-Wen

    2015-01-01

    Recently, the International Agency for Research on cancer classified outdoor air pollution and particulate matter from outdoor air pollution as carcinogenic to humans (IARC Group 1), based on sufficient evidence of carcinogenicity in humans and experimental animals and strong mechanistic evidence. In particular, a wide variety of volatile organic compounds (VOCs) are volatized or released into the atmosphere and can become ubiquitous, as they originate from many different natural and anthropogenic sources, such as paints, pesticides, vehicle exhausts, cooking fumes, and tobacco smoke. Humans may be exposed to VOCs through inhalation, ingestion, or dermal contact, which may increase the risk of leukemia, birth defects, neurocognitive impairment, and cancer. Therefore, the focus of this study was the development of a simple, effective and rapid sample preparation method for the simultaneous determination of seven metabolites (6 mercaptic acids+t,t-muconic acid) derived from five VOCs (acrylamide, 1,3-butadiene, acrylonitrile, benzene, and xylene) in human urine by using automated on-line solid-phase extraction (SPE) coupled with liquid chromatography-electrospray tandem mass spectrometry (LC-MS/MS). An aliquot of each diluted urinary sample was directly injected into an autosampler through a trap column to reduce contamination, and then the retained target compounds were eluted by back-flush mode into an analytical column for separation. Negative electrospray ionization tandem mass spectrometry was utilized for quantification. The coefficients of correlation (r(2)) for the calibration curves were greater than 0.995. Reproducibility was assessed by the precision and accuracy of intra-day and inter-day precision, which showed results for coefficient of variation (CV) that were low 0.9 to 6.6% and 3.7 to 8.5%, respectively, and results for recovery that ranged from 90.8 to 108.9% and 92.1 to 107.7%, respectively. The limits of detection (LOD) and limits of

  19. Determination of the oxidative stress biomarker urinary 8-hydroxy-2'-deoxyguanosine by automated on-line in-tube solid-phase microextraction coupled with liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Kataoka, Hiroyuki; Mizuno, Keisuke; Oda, Eri; Saito, Akihiro

    2016-04-15

    A simple and sensitive method for the determination of 8-hydroxy-2'-deoxyguanosine (8-OHdG), a marker of oxidative DNA damage in human urine, was developed using automated on-line in-tube solid-phase microextraction (SPME) coupled with stable isotope-dilution liquid chromatography-tandem mass spectrometry (LC-MS/MS). Creatinine was also analyzed simultaneously to normalize urine volume by the in-tube SPME LC-MS/MS method, and 8-OHdG and creatinine were separated within 3 min using a Zorbax Eclipse XDB-C8 column. Electrospray MS/MS for these compounds was performed on an API 4000 triple quadruple mass spectrometer in the positive ion mode by multiple reaction monitoring. The optimum in-tube SPME conditions were 20 draw/eject cycles of 40 μL of sample at a flow rate of 200 μL/min using a Carboxen 1006 PLOT capillary column as an extraction device. The extracted compounds were easily desorbed from the capillary by passage of the mobile phase, and no carryover was observed. The calibration curve for 8-OHdG using its stable isotope-labeled internal standard was linear in the range of 0.05-10 ng/mL, and the detection limit was 8.3 pg/mL. The intra-day and inter-day precision (relative standard deviations) were below 3.1% and 9.6% (n=5), respectively. This method was applied successfully to the analysis of urine samples without any other pretreatment and interference peaks, with good recovery rates above 91% in spiked urine samples. The limits of quantification of 8-OHdG and creatinine in 0.1 mL urine samples were about 0.32 and 0.69 ng/mL (S/N=10), respectively. This method was utilized to assess the effects of smoking, green tea drinking and alcohol drinking on the urinary excretion of 8-OHdG. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Analysis of nicotine and cotinine in hair by on-line in-tube solid-phase microextraction coupled with liquid chromatography-tandem mass spectrometry as biomarkers of exposure to tobacco smoke.

    Science.gov (United States)

    Inukai, Takehito; Kaji, Sanae; Kataoka, Hiroyuki

    2018-07-15

    Smoking not only increases the risk of lung cancer but is strongly related to the onset of cardiovascular disease. Particularly, passive smoking due to sidestream smoke is a critical public health problem. To assess active and passive exposure to tobacco smoke, we developed a simple and sensitive method, consisting of on-line in-tube solid phase microextraction (SPME) coupled with liquid chromatography-tandem mass spectrometry (LC-MS/MS), to determine nicotine and its metabolite cotinine in hair samples. These compounds were separated within 5 min using a Polar-RP80A column and detected in the positive ion mode by multiple reaction monitoring. The optimum in-tube SPME conditions were 25 draw/eject cycles of 40 μL of sample at a flow rate of 200 μL/min using a Carboxen 1006 capillary column as an extraction device. The extracted compounds in the stationary phase on the inner wall of the capillary could be dissolved easily into the mobile phase and transferred to an LC column. Using the in-tube SPME LC-MS/MS method, the calibration curves were linear in the 5-1000 pg/mL ranges for nicotine and cotinine, and the detection limits (signal to noise ratio of 3) were 0.45 and 0.13 pg/mL, respectively. The intra-day and inter-day precisions were below 3.4% and 6.0% (n = 5), respectively. This method was utilized successfully to analyze pg/mg levels of nicotine and cotinine in 1 mg of hairs without interference peaks, and good recoveries were obtained. The concentration of cotinine in hair was two orders of magnitude lower than that of nicotine, but a good positive correlation was found between the concentrations of these compounds. This method can automate the extraction, concentration and analysis of samples, and is useful for the assessment of long-term exposure to tobacco smoke. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. Solid-phase extraction of polar pesticides from environmental water samples on graphitized carbon and Empore-activated carbon disks and on-line coupling to octadecyl-bonded silica analytical columns.

    NARCIS (Netherlands)

    Slobodník, J.; Oztekizan, O.; Lingeman, H.; Brinkman, U.A.T.

    1996-01-01

    The suitability of Empore-activated carbon disks (EACD), Envi-Carb graphitized carbon black (GCB) and CPP-50 graphitized carbon for the trace enrichment of polar pesticides from water samples was studied by means of off-line and on-line solid-phase extraction (SPE). In the off-line procedure, 0.5-2

  2. Determination of trace metal ions via on-line separation and preconcentration by means of chelating Sepharose beads in a sequential injection lab-on-valve (SI-LOV) system coupled to electrothermal atomic absorption spectrometric detection

    DEFF Research Database (Denmark)

    Long, Xiangbao; Hansen, Elo Harald; Miró, Manuel

    2005-01-01

    The analytical performance of an on-line sequential injection lab-on-valve (SI-LOV) system using chelating Sepharose beads as sorbent material for the determination of ultra trace levels of Cd(II), Pb(II) and Ni(II) by electrothermal atomic absorption spectrometry (ETAAS) is described and discussed...

  3. A field survey of metal binding to metallothionein and other cytosolic ligands in liver of eels using an on-line isotope dilution method in combination with size exclusion (SE) high pressure liquid chromatography (HPLC) coupled to Inductively Coupled Plasma time-of-flight Mass Spectrometry (ICP-TOFMS).

    Science.gov (United States)

    Van Campenhout, Karen; Goenaga Infante, Heidi; Goemans, Geert; Belpaire, Claude; Adams, Freddy; Blust, Ronny; Bervoets, Lieven

    2008-05-15

    The effect of metal exposure on the accumulation and cytosolic speciation of metals in livers of wild populations of European eel with special emphasis on metallothioneins (MT) was studied. Four sampling sites in Flanders showing different degrees of heavy metal contamination were selected for this purpose. An on-line isotope dilution method in combination with size exclusion (SE) high pressure liquid chromatography (HPLC) coupled to Inductively Coupled Plasma time-of-flight Mass Spectrometry (ICP-TOFMS) was used to study the cytosolic speciation of the metals. The distribution of the metals Cd, Cu, Ni, Pb and Zn among cytosolic fractions displayed strong differences. The cytosolic concentration of Cd, Ni and Pb increased proportionally with the total liver levels. However, the cytosolic concentrations of Cu and Zn only increased above a certain liver tissue threshold level. Cd, Cu and Zn, but not Pb and Ni, were largely associated with the MT pool in correspondence with the environmental exposure and liver tissue concentrations. Most of the Pb and Ni and a considerable fraction of Cu and Zn, but not Cd, were associated to High Molecular Weight (HMW) fractions. The relative importance of the Cu and Zn in the HMW fraction decreased with increasing contamination levels while the MT pool became progressively more important. The close relationship between the cytosolic metal load and the total MT levels or the metals bound on the MT pool indicates that the metals, rather than other stress factors, are the major factor determining MT induction.

  4. Solid-phase extraction of polar pesticides from environmental water samples on graphitized carbon and Empore-activated carbon disks and on-line coupling to octadecyl-bonded silica analytical columns.

    Science.gov (United States)

    Slobodník, J; Oztezkizan, O; Lingeman, H; Brinkman, U A

    1996-10-25

    The suitability of Empore-activated carbon disks (EACD), Envi-Carb graphitized carbon black (GCB) and CPP-50 graphitized carbon for the trace enrichment of polar pesticides from water samples was studied by means of off-line and on-line solid-phase extraction (SPE). In the off-line procedure, 0.5-2 l samples spiked with a test mixture of oxamyl, methomyl and aldicarb sulfoxide were enriched on EnviCarb SPE cartridges or 47 mm diameter EACD and eluted with dichloromethane-methanol. After evaporation, a sample was injected onto a C18-bonded silica column and analysed by liquid chromatography with ultraviolet (LC-UV) detection. EACD performed better than EnviCarb cartridges in terms of breakthrough volumes (> 2 l for all test analytes), reproducibility (R.S.D. of recoveries, 4-8%, n = 3) and sampling speed (100 ml/min); detection limits in drinking water were 0.05-0.16 microgram/l. In the on-line experiments, 4.6 mm diameter pieces cut from original EACD and stacked onto each other in a 9 mm long precolumn, and EnviCarb and CPP-50 packed in 10 x 2.0 mm I.D. precolumn, were tested, and 50-200 ml spiked water samples were preconcentrated. Because of the peak broadening caused by the strong sorption of the analytes on carbon, the carbon-packed precolumns were eluted by a separate stream of 0.1 ml/min acetonitrile which was mixed with the gradient LC eluent in front of the C18 analytical column. The final on-line procedure was also applied for the less polar propoxur, carbaryl and methiocarb. EnviCarb could not be used due to its poor pressure resistance. CPP-50 provided less peak broadening than EACD: peak widths were 0.1-0.3 min and R.S.D. of peak heights 4-14% (n = 3). In terms of analyte trapping efficiency on-line SPE-LC-UV with a CPP-50 precolumn also showed better performance than when Bondesil C18/OH or polymeric PLRP-S was used, but chromatographic resolution was similar. With the CPP-50-based system, detection limits of the test compounds were 0.05-1 microgram

  5. CERN Video News on line

    CERN Multimedia

    2003-01-01

    The latest CERN video news is on line. In this issue : an interview with the Director General and reports on the new home for the DELPHI barrel and the CERN firemen's spectacular training programme. There's also a vintage video news clip from 1954. See: www.cern.ch/video or Bulletin web page

  6. Coupling on-line preconcentration by ion-exchange with ETAAS. A novel flow injection approach based on the use of a renewable microcolumn as demonstrated for the determination of nickel in environmental and biological samples

    DEFF Research Database (Denmark)

    Wang, Jianhua; Hansen, Elo Harald

    2000-01-01

    microcolumn incorporated within an integrated micro FI-system, the column is loaded with a defined volume of small beads of an SP Sephadex C-25 cation-exchange resin and subsequently exposed to a metered amount of sample solution. However, instead of eluting the retained analyte from the organic ion-exchange......A novel way of exploiting flow injection/sequential injection (FIA/SIA) on-line ion-exchange preconcentration with detection by electrothermal atomic absorption spectrometry (ETAAS) is described and demonstrated for the determination of trace-levels of nickel. Based on the use of a renewable...... resin, the beads are along with 30 mul of carrier (buffer) solution transported via air segmentation directly into the graphite tube, where they are ashed during the pyrolysis and atomization process. The ETAAS determination is performed in parallel with the preconcentration process of the ensuing...

  7. Separation of seven arsenic compounds by high performance liquid chromatography with on-line detection by hydrogen-argon flame atomic absorption spectrometry and inductively coupled plasma mass spectrometry

    DEFF Research Database (Denmark)

    Hansen, S. H.; Larsen, Erik Huusfeldt; Pritzl, G.

    1992-01-01

    -to-noise ratio of the on-line AAS detector was optimized. This involved the use of the hydrogen-argon-entrained air flame, a slotted tube atom trap in the flame for signal enhancement, electronic noise damping and a high-intensity light source. The detection limits in mu-g cm-3, using 100 mm3 injections...... of mixtures of arsenic standards into the HPLC system were: arsenite, As(III) 1.1; arsenate, As(V) 1.4; MMA 1.4; DMA 0.7; AsB 0.3; AsC 0.5; and the TMAs 0.4. The HPLC-AAS system was used for the analysis of arsenic species in aqueous extracts of soil samples from a polluted land site. Only arsenate was found...

  8. Sequential injection-bead injection-lab-on-valve schemes for on-line solid phase extraction and preconcentration of ultra-trace levels of heavy metals with determination by electrothermal atomic absorption spectrometry and inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Wang Jianhua; Hansen, Elo Harald; Miro, Manuel

    2003-01-01

    This communication presents an overview of the state-of-the-art of the exploitation of sequential injection (SI)-bead injection (BI)-lab-on-valve (LOV) schemes for automatic on-line sample pre-treatments interfaced with ETAAS and ICPMS detection as conducted in the authors' group. The discussions are focused on the applications of SI-BI-LOV protocols for on-line microcolumn based solid phase extraction of ultra-trace levels of heavy metals, employing the so-called renewable surface separation and preconcentration manipulatory scheme. Two types of sorbents have been employed as packing material, that is, the hydrophilic SP Sephadex C-25 cation exchange and iminodiacetate based Muromac A-1 chelating resins, and the hydrophobic poly(tetrafluoroethylene) (PTFE) and poly(styrene-divinylbenzene) copolymer alkylated with octadecyl groups (C 18 -PS/DVB). Using ETAAS as detection device, the easy-to-handle hydrophilic renewable reactors hold the features of improved R.S.D.s and LODs as compared to those operated in the conventional, permanent mode, in addition to the elimination of flow resistance. The hydrophobic columns fall into two categories, that is, the renewable one packed with C 18 -PS/DVB beads entails analogous R.S.D.s and LODs with respect to the conventional approach, while those with PTFE beads result in slightly inferior R.S.D.s and LODs by similar comparison, yet offering a wider dynamic range than when using an external permanent column. Moreover, the hydrophilic materials result in much higher enrichment of the analyte than the hydrophobic ones, although PTFE is the packing material that exhibits the best retention efficiency

  9. On-line moisture analysis

    CERN Document Server

    Cutmore, N G

    2002-01-01

    Measurement of the moisture content of iron ore has become a key issue for controlling moisture additions for dust suppression. In most cases moisture content is still determined by manual or automatic sampling of the ore stream, followed by conventional laboratory analysis by oven drying. Although this procedure enables the moisture content to be routinely monitored, it is too slow for control purposes. This has generated renewed interest in on-line techniques for the accurate and rapid measurement of moisture in iron ore on conveyors. Microwave transmission techniques have emerged over the past 40 years as the dominant technology for on-line measurement of moisture in bulk materials, including iron ores. Alternative technologies have their limitations. Infra-red analysers are used in a variety of process industries, but rely on the measurement of absorption by moisture in a very thin surface layer. Consequently such probes may be compromised by particle size effects and biased presentation of the bulk mater...

  10. Reversed-phase liquid chromatography coupled on-line with capillary gas chromatography use of an anion-exchange membrane to remove an ion-pair reagent from the eluent.

    NARCIS (Netherlands)

    Brinkman, U.A.T.; Goosens, E.C.; de Jong, D.; de Jong, G.J.; Beerthuizen, I.M.

    1995-01-01

    In order to enable the coupling of reversed-phase liquid chromatography (RPLC) with capillary gas chromatography (GC), the performance of an anion-exchange micromembrane device has been studied to remove the ion-pair reagent methanesulphonic acid from an acetonitrile/water LC eluent. The regenerant

  11. Development of an on-line solid phase extraction ultra-high-performance liquid chromatography technique coupled to tandem mass spectrometry for quantification of bisphenol S and bisphenol S glucuronide: Applicability to toxicokinetic investigations.

    Science.gov (United States)

    Grandin, Flore; Picard-Hagen, Nicole; Gayrard, Véronique; Puel, Sylvie; Viguié, Catherine; Toutain, Pierre-Louis; Debrauwer, Laurent; Lacroix, Marlène Z

    2017-12-01

    Regulatory measures and public concerns regarding bisphenol A (BPA) have led to its replacement by structural analogues, such as Bisphenol S (BPS), in consumer products. At present, no toxicokinetic investigations have been conducted to assess the factors determining human internal exposure to BPS for subsequent risk assessment. Toxicokinetic studies require reliable analytical methods to measure the plasma concentrations of BPS and its main conjugated metabolite, BPS-glucuronide (BPS-G). An efficient on-line SPE-UPLC-MS/MS method for the simultaneous quantification of BPS and BPS-G in ovine plasma was therefore developed and validated in accordance with the European Medicines Agency guidelines for bioanalytical method validation. This method has a limit of quantification of 3ngmL -1 for BPS and 10ngmL -1 for BPS-G, an analytical capacity of 200 samples per day, and is particularly well suited to toxicokinetic studies. Use of this method in toxicokinetic studies in sheep showed that BPS, like BPA, is efficiently metabolized into its glucuronide form. However, the clearances and distributions of BPS and BPS-G were lower than those of the corresponding unconjugated and glucuroconjugated forms of BPA. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. On line ultrasonic integrated backscatter

    International Nuclear Information System (INIS)

    Landini, L.; Picano, E.; Mazzarisi, A.; Santarelli, F.; Benassi, A.; De Pieri, G.

    1988-01-01

    A new equipment for on-line evaluation of index based on two-dimensional integrated backscatter from ultrasonic images is described. The new equipment is fully integrated into a B-mode ultrasonic apparatus which provides a simultaneous display of conventional information together with parameters of tissue characterization. The system has been tested with a backscattering model of microbubbles in polysaccharide solution, characterized by a physiological exponential time decay. An exponential fitting to the experimental data was performed which yielded r=0.95

  13. On-line nuclear orientation

    International Nuclear Information System (INIS)

    Krane, K.S.

    1990-01-01

    This grant has as its overall goal the pursuit of on-line nuclear orientation experiments for the purpose of eliciting details of nuclear structure from the decays of neutron-deficient nuclei, such as those produced by the Holifield Heavy-Ion Research Facility at Oak Ridge and extracted by the UNISOR Isotope Separator. This paper discusses: refrigerator development; the decay of 184 Au; the decay of 191 Hg to 191 Au; the decay of 189 Pt to 189 Ir; the decays of 109,111 Pd; the decay of 172 Er; and solid angle corrections

  14. Couplings

    Science.gov (United States)

    Stošić, Dušan; Auroux, Aline

    Basic principles of calorimetry coupled with other techniques are introduced. These methods are used in heterogeneous catalysis for characterization of acidic, basic and red-ox properties of solid catalysts. Estimation of these features is achieved by monitoring the interaction of various probe molecules with the surface of such materials. Overview of gas phase, as well as liquid phase techniques is given. Special attention is devoted to coupled calorimetry-volumetry method. Furthermore, the influence of different experimental parameters on the results of these techniques is discussed, since it is known that they can significantly influence the evaluation of catalytic properties of investigated materials.

  15. Simultaneous analysis of aspartame and its hydrolysis products of Coca-Cola Zero by on-line postcolumn derivation fluorescence detection and ultraviolet detection coupled two-dimensional high-performance liquid chromatography.

    Science.gov (United States)

    Cheng, Cheanyeh; Wu, Shing-Chen

    2011-05-20

    An innovative two-dimensional high-performance liquid chromatography system was developed for the simultaneous analysis of aspartame and its hydrolysis products of Coca-Cola Zero. A C8 reversed-phase chromatographic column with ultraviolet detection was used as the first dimension for the determination of aspartame, and a ligand-exchange chromatographic column with on-line postcolumn derivation fluorescence detection was employed as the second dimension for the analysis of amino acid enantiomers. The fluorimetric derivative reagent of amino acid enantiomers was o-phthaldialdehyde. The hydrolysis of aspartame in Coca-Cola Zero was induced by electric-heating or microwave heating. Aspartame was quantified by the matrix matched external standard calibration curve with a linear concentration range of 0-50 μg mL(-1) (r(2)=0.9984). The limit of detection (LOD) and the limit of quantification (LOQ) were 1.3 μg mL(-1) and 4.3 μg mL(-1), respectively. The amino acid enantiomers was analyzed by the matrix matched internal standard calibration method (D-leucine as the internal standard) with a linear concentration range of 0-10 μg mL(-1) (r(2)=0.9988-0.9997). The LODs and LOQs for L- and D-aspartic acid and L- and D-phenylalanine were 0.16-0.17 μg mL(-1) and 0.52-0.55 μg mL(-1), respectively, that was 12-13 times more sensitive than ultraviolet detection. The overall analysis accuracy for aspartame and amino acid enantiomers was 90.2-99.2% and 90.4-96.2%, respectively. The overall analysis precision for aspartame and amino acid enantiomers was 0.1-1.7% and 0.5-6.7%, respectively. Generally, the extent of aspartame hydrolysis increases with the increase of electro-thermal temperature, microwave power, and the duration of hydrolysis time. D-aspartic acid and D-phenylalanine can be observed with the electro-thermal racemization at the hydrolysis temperature 120°C for 1 day and only D-aspartic acid can be observed at the hydrolysis temperature 90°C for 2 and 3 days. For

  16. On-line solid-phase enrichment coupled to packed reactor flow injection analysis in a green analytical procedure to determine low levels of folic acid using fluorescence detection

    Directory of Open Access Journals (Sweden)

    Emara Samy

    2012-12-01

    Full Text Available Abstract Background Analysis of folic acid (FA is not an easy task because of its presence in lower concentrations, its lower stability under acidic conditions, and its sensitiveness against light and high temperature. The present study is concerned with the development and validation of an automated environmentally friendly pre-column derivatization combined by solid-phase enrichment (SPEn to determine low levels of FA. Results Cerium (IV trihydroxyhydroperoxide (CTH as a packed oxidant reactor has been used for oxidative cleavage of FA into highly fluorescent product, 2-amino-4-hydroxypteridine-6-carboxylic acid. FA was injected into a carrier stream of 0.04 M phosphate buffer, pH 3.4 at a flow-rate of 0.25 mL/min. The sample zone containing the analyte was passed through the CTH reactor thermostated at 40°C, and the fluorescent product was trapped and enriched on a head of small ODS column (10 mm x 4.6 mm i.d., 5 μm particle size. The enriched product was then back-flush eluted by column-switching from the small ODS column to the detector with a greener mobile phase consisting of ethanol and phosphate buffer (0.04M, pH 3.4 in the ratio of 5:95 (v/v. The eluent was monitored fluorimetrically at emission and excitation wavelengths of 463 and 367 nm, respectively. The calibration graph was linear over concentrations of FA in the range of 1.25-50 ng/mL, with a detection limit of 0.49 ng/mL. Conclusion A new simple and sensitive green analytical procedure including on-line pre-column derivatization combined by SPEn has been developed for the routine quality control and dosage form assay of FA at very low concentration level. The method was a powerful analytical technique that had excellent sensitivity, sufficient accuracy and required relatively simple and inexpensive instrumentation.

  17. The on-line coupled atmospheric chemistry model system MECO(n) - Part 5: Expanding the Multi-Model-Driver (MMD v2.0) for 2-way data exchange including data interpolation via GRID (v1.0)

    Science.gov (United States)

    Kerkweg, Astrid; Hofmann, Christiane; Jöckel, Patrick; Mertens, Mariano; Pante, Gregor

    2018-03-01

    As part of the Modular Earth Submodel System (MESSy), the Multi-Model-Driver (MMD v1.0) was developed to couple online the regional Consortium for Small-scale Modeling (COSMO) model into a driving model, which can be either the regional COSMO model or the global European Centre Hamburg general circulation model (ECHAM) (see Part 2 of the model documentation). The coupled system is called MECO(n), i.e., MESSy-fied ECHAM and COSMO models nested n times. In this article, which is part of the model documentation of the MECO(n) system, the second generation of MMD is introduced. MMD comprises the message-passing infrastructure required for the parallel execution (multiple programme multiple data, MPMD) of different models and the communication of the individual model instances, i.e. between the driving and the driven models. Initially, the MMD library was developed for a one-way coupling between the global chemistry-climate ECHAM/MESSy atmospheric chemistry (EMAC) model and an arbitrary number of (optionally cascaded) instances of the regional chemistry-climate model COSMO/MESSy. Thus, MMD (v1.0) provided only functions for unidirectional data transfer, i.e. from the larger-scale to the smaller-scale models.Soon, extended applications requiring data transfer from the small-scale model back to the larger-scale model became of interest. For instance, the original fields of the larger-scale model can directly be compared to the upscaled small-scale fields to analyse the improvements gained through the small-scale calculations, after the results are upscaled. Moreover, the fields originating from the two different models might be fed into the same diagnostic tool, e.g. the online calculation of the radiative forcing calculated consistently with the same radiation scheme. Last but not least, enabling the two-way data transfer between two models is the first important step on the way to a fully dynamical and chemical two-way coupling of the various model instances.In MMD (v1

  18. The on-line coupled atmospheric chemistry model system MECO(n – Part 5: Expanding the Multi-Model-Driver (MMD v2.0 for 2-way data exchange including data interpolation via GRID (v1.0

    Directory of Open Access Journals (Sweden)

    A. Kerkweg

    2018-03-01

    Full Text Available As part of the Modular Earth Submodel System (MESSy, the Multi-Model-Driver (MMD v1.0 was developed to couple online the regional Consortium for Small-scale Modeling (COSMO model into a driving model, which can be either the regional COSMO model or the global European Centre Hamburg general circulation model (ECHAM (see Part 2 of the model documentation. The coupled system is called MECO(n, i.e., MESSy-fied ECHAM and COSMO models nested n times. In this article, which is part of the model documentation of the MECO(n system, the second generation of MMD is introduced. MMD comprises the message-passing infrastructure required for the parallel execution (multiple programme multiple data, MPMD of different models and the communication of the individual model instances, i.e. between the driving and the driven models. Initially, the MMD library was developed for a one-way coupling between the global chemistry–climate ECHAM/MESSy atmospheric chemistry (EMAC model and an arbitrary number of (optionally cascaded instances of the regional chemistry–climate model COSMO/MESSy. Thus, MMD (v1.0 provided only functions for unidirectional data transfer, i.e. from the larger-scale to the smaller-scale models.Soon, extended applications requiring data transfer from the small-scale model back to the larger-scale model became of interest. For instance, the original fields of the larger-scale model can directly be compared to the upscaled small-scale fields to analyse the improvements gained through the small-scale calculations, after the results are upscaled. Moreover, the fields originating from the two different models might be fed into the same diagnostic tool, e.g. the online calculation of the radiative forcing calculated consistently with the same radiation scheme. Last but not least, enabling the two-way data transfer between two models is the first important step on the way to a fully dynamical and chemical two-way coupling of the various model

  19. On-line moisture analysis

    International Nuclear Information System (INIS)

    Cutmore, N.G.; Mijak, D.G

    2002-01-01

    Measurement of the moisture content of iron ore has become a key issue for controlling moisture additions for dust suppression. In most cases moisture content is still determined by manual or automatic sampling of the ore stream, followed by conventional laboratory analysis by oven drying. Although this procedure enables the moisture content to be routinely monitored, it is too slow for control purposes. This has generated renewed interest in on-line techniques for the accurate and rapid measurement of moisture in iron ore on conveyors. Microwave transmission techniques have emerged over the past 40 years as the dominant technology for on-line measurement of moisture in bulk materials, including iron ores. Alternative technologies have their limitations. Infra-red analysers are used in a variety of process industries, but rely on the measurement of absorption by moisture in a very thin surface layer. Consequently such probes may be compromised by particle size effects and biased presentation of the bulk material. Nuclear-based analysers measure the total hydrogen content in the sample and do not differentiate between free and combined moisture. Such analysers may also be sensitive to material presentation and elemental composition. Very low frequency electromagnetic probes, such as capacitance or conductance probes, operate in the frequency region where the DC conductivity dominates much of the response, which is a function not only of moisture content but also of ionic composition and chemistry. These problems are overcome using microwave transmission techniques, which also have the following advantages, as a true bulk moisture analysis is obtained, because a high percentage of the bulk material is analysed; the moisture estimate is mostly insensitive to any biased presentation of moisture, for example due to stratification of bulk material with different moisture content and because no physical contact is made between the sensor and the bulk material. This is

  20. On-Line Synthesis and Analysis by Mass Spectrometry

    Science.gov (United States)

    Bain, Ryan M.; Pulliam, Christopher J.; Raab, Shannon A.; Cooks, R. Graham

    2015-01-01

    In this laboratory experiment, students learn how to use ESI to accelerate chemical synthesis and to couple it with on-line mass spectrometry for structural analysis. The Hantzsch synthesis of symmetric 1,4-dihydropyridines is a classic example of a one-pot reaction in which multiple intermediates can serve to indicate the progress of the reaction…

  1. Flow analysis by using solenoid valves for As(III determination in natural waters by an on-line separation and pre-concentration system coupled to a tungsten coil atomizer

    Directory of Open Access Journals (Sweden)

    José Y. Neira

    2005-03-01

    Full Text Available A flow system coupled to a tungsten coil atomizer in an atomic absorption spectrometer (TCA-AAS was developed for As(III determination in waters, by extraction with sodium diethyldithiocarbamate (NaDDTC as complexing agent, and by sorption of the As(III-DDTC complex in a micro-column filled with 5 mg C18 reversed phase (10 µL dry sorbent, followed by elution with ethanol. A complete pre-concentration/elution cycle took 208 s, with 30 s sample load time (1.7 mL and 4 s elution time (71 µL. The interface and software for the synchronous control of two peristaltic pumps (RUN/ STOP, an autosampler arm, seven solenoid valves, one injection valve, the electrothermal atomizer and the spectrometer Read function were constructed. The system was characterized and validated by analytical recovery studies performed both in synthetic solutions and in natural waters. Using a 30 s pre-concentration period, the working curve was linear between 0.25 and 6.0 µg L-1 (r = 0.9976, the retention efficiency was 94±1% (6.0 µg L-1, and the pre-concentration coefficient was 28.9. The characteristic mass was 58 pg, the mean repeatability (expressed as the variation coefficient was 3.4% (n=5, the detection limit was 0.058 µg L-1 (4.1 pg in 71 µL of eluate injected into the coil, and the mean analytical recovery in natural waters was 92.6 ± 9.5 % (n=15. The procedure is simple, economic, less prone to sample loss and contamination and the useful lifetime of the micro-column was between 200-300 pre-concentration cycles.

  2. On-line data display

    Science.gov (United States)

    Lang, Sherman Y. T.; Brooks, Martin; Gauthier, Marc; Wein, Marceli

    1993-05-01

    A data display system for embedded realtime systems has been developed for use as an operator's user interface and debugging tool. The motivation for development of the On-Line Data Display (ODD) have come from several sources. In particular the design reflects the needs of researchers developing an experimental mobile robot within our laboratory. A proliferation of specialized user interfaces revealed a need for a flexible communications and graphical data display system. At the same time the system had to be readily extensible for arbitrary graphical display formats which would be required for data visualization needs of the researchers. The system defines a communication protocol transmitting 'datagrams' between tasks executing on the realtime system and virtual devices displaying the data in a meaningful way on a graphical workstation. The communication protocol multiplexes logical channels on a single data stream. The current implementation consists of a server for the Harmony realtime operating system and an application written for the Macintosh computer. Flexibility requirements resulted in a highly modular server design, and a layered modular object- oriented design for the Macintosh part of the system. Users assign data types to specific channels at run time. Then devices are instantiated by the user and connected to channels to receive datagrams. The current suite of device types do not provide enough functionality for most users' specialized needs. Instead the system design allows the creation of new device types with modest programming effort. The protocol, design and use of the system are discussed.

  3. Strengthening weak ties through on-line gaming

    DEFF Research Database (Denmark)

    Sudzina, Frantisek; Razmerita, Liana Virginia; Kirchner, Kathrin

    On-line gaming became widespread in the last couple of years. The aim of the research presented in the paper is to figure out to what extent does game playing helps to strengthen weak ties and what additional factors influence this process. The approach is rather exploratory – some factors...... are grounded in theory, some are new. These factors are age, gender, place of origin, number of their Facebook connections (friends in Facebook terminology), the amount of time they are on Facebook, the amount of time they keep the Facebook site open, the amount of time they play on-line games, and the reasons...... for starting to play on-line games. Regarding the latter, we chose to focus only on escapist reasons....

  4. Modeling of On-Line Catalyst Addition Effects in a Short Contact Time Reactor

    National Research Council Canada - National Science Library

    Zerkle, David K; Allendorf, Mark Donald; Wolf, Markus; Deutschmann, Olaf

    2000-01-01

    ... operating ( on-line catalyst addition). Our simulations indicate that the fundamental behavior of the ethane SCTR prepared with catalyst added online is the result of coupled heterogeneous and homogeneous chemical processes...

  5. Box-Behnken design for optimum extraction of biogenetic chemicals from P. lanceolata with an energy audit (thermal × microwave × acoustic): a case study of HPTLC determination with additional specificity using on-line/off-line coupling with DAD/NIR/ESI-MS.

    Science.gov (United States)

    Srivastava, Pooja; Ajayakumar, P V; Shanker, Karuna

    2014-01-01

    The genus Pluchea comprises about 80 species distributed worldwide, out of them, only Pluchea lanceolata (DC.) Oliv. & Hiern, is used extensively in the traditional system of India. No chromatographic method is available for its quality. To perform the energy audit for the extraction of biogenetic pentacyclic triterpene, its acetate and sterol from P. lanceolata utilising organic and four alternative solvents. Additionally to resolve the uncertainty of TLC determination, on-line/off-line coupling with a diode-array detector (DAD), and near-infrared (NIR) and electrospray ionisation (ESI) MS was introduced. The extraction of taraxasterol (Tx), taraxasterol acetate (TxAc) and stigmasterol (St) from P. lanceolata was performed using three energy modes. The effects of different operating parameters were studied for optimum extraction yield using the design of experiments, that is, the central composite design and Box-Behnken design. In addition to the retention factor (Rf ) and visible spectral matching, two additional optical spectroscopic techniques, that is, NIR and ESI-MS, were applied for extended specificity. The method was developed for Tx, TxAc and St determination using HPTLC at 645 nm. The optimum extraction yield of targeted compounds was found to be higher with organic solvents than eco-friendly surfactants. The pulse ultrasonic assisted extraction (PUAE) has resulted in optimum extraction of compounds comparable to hot extraction. Both NIR and ESI-MS provided extended specificity in determination. The 5/1-PUAE was determined to be effective, reproducible, simple and energy efficient for the determination of Tx, TxAc and St in P. lanceolata. The offline coupling of NIR and ESI-MS with HPTLC led to considerable improvement in specificity. Copyright © 2014 John Wiley & Sons, Ltd.

  6. Shawnee Mission's On-Line Cataloging System

    Directory of Open Access Journals (Sweden)

    Ellen Wasby Miller

    1971-03-01

    Full Text Available An on-line cataloging pilot project for two elementary schools is discussed. The system components are 2740 terminals, upper-lower-case input, IBM's FASTER generalized software package, and usual cards/labels output. Reasons for choosing FASTER, software and hardware features, operating procedures, system performance and costs are detailed. Future expansion to cataloging 100,000 annual K-12 acquisitions, on-line circulation, retrospective conversion, and union book catalogs is set forth.

  7. INIS retrieval service, towards on-line

    International Nuclear Information System (INIS)

    Ebinuma, Yukio; Komatsubara, Yasutoshi

    1983-01-01

    Japan Atomic Energy Research Institute executes the retrieval service of INIS atomic energy information by batch system in cooperation with Genshiryoku Kozaikai. This service is very popular to the users in whole Japan, but the demand of on-line service has increased recently. Therefore, it was decided to begin the INIS on-line service from January, 1984, through the on-line information retrieval system of the Japan Information Center of Science and Technology. It is expected that when the operation will be started, the utilization of INIS atomic energy information in Japan will drastically increase. Also Japan Atomic Energy Research Institute has carried out the retrieval service by on-line system for those in the institute besides the batch system, accordingly, at this opportunity, the state of utilization of both systems and their distinction to use effectively, and the operation and the method of utilization of the on-line information retrieval system of JICST are explained. In the on-line system, the users are accessible to the data base themselves, and immediate information retrieval is possible, while in the batch system, the related information can be retrieved without fail, and the troublesome operation of equipment is not necessary. (Kako, I.)

  8. Structural bifurcation of microwave helium jet discharge at atmospheric pressure

    International Nuclear Information System (INIS)

    Takamura, Shuichi; Kitoh, Masakazu; Soga, Tadasuke

    2008-01-01

    Structural bifurcation of microwave-sustained jet discharge at atmospheric gas pressure was found to produce a stable helium plasma jet, which may open the possibility of a new type of high-flux test plasma beam for plasma-wall interactions in fusion devices. The fundamental discharge properties are presented including hysteresis characteristics, imaging of discharge emissive structure, and stable ignition parameter area. (author)

  9. Connection experiments with a hollow cathode ion source and a helium gas jet system for on-line isotope separation

    International Nuclear Information System (INIS)

    Mazumdar, A.K.; Wagner, H.; Walcher, W.; Lund, T.

    1976-01-01

    A helium jet system was connected to a hollow cathode ion source. Using fission products the efficiencies of the different steps were measured by β-, X-ray and γ-counting while the mass spectrum and the focussing of the extracted ion beam were observed with a small deflecting magnet. Mean transport efficiencies of 50% through the 12 m capillary were obtained and ion source efficiencies in the percent range for several elements. (Auth.)

  10. Integrated on-line accelerator modeling at CEBAF

    International Nuclear Information System (INIS)

    Bowling, B.A.; Shoaee, H.; Van Zeijts, J.; Witherspoon, S.; Watson, W.

    1995-01-01

    An on-line accelerator modeling facility is currently under development at CEBAF. The model server, which is integrated with the EPICS control system, provides coupled and 2nd-order matrices for the entire accelerator, and forms the foundation for automated model- based control and diagnostic applications. Four types of machine models are provided, including design, golden or certified, live, and scratch or simulated model. Provisions are also made for the use of multiple lattice modeling programs such as DIMAD, PARMELA, and TLIE. Design and implementation details are discussed. 2 refs., 4 figs

  11. On-line monitoring for calibration reduction

    International Nuclear Information System (INIS)

    Hoffmann, M.

    2005-09-01

    On-Line Monitoring evaluates instrument channel performance by assessing its consistency with other plant indications. Elimination or reduction of unnecessary field calibrations can reduce associated labour costs, reduce personnel radiation exposure, and reduce the potential for calibration errors. On-line calibration monitoring is an important technique to implement a state-based maintenance approach and reduce unnecessary field calibrations. In this report we will look at how the concept is currently applied in the industry and what the arising needs are as it becomes more commonplace. We will also look at the PEANO System, a tool developed by the Halden Project to perform signal validation and on-line calibration monitoring. Some issues will be identified that are being addressed in the further development of these tools to better serve the future needs of the industry in this area. An outline for how to improve these points and which aspects should be taken into account is described in detail. (Author)

  12. On-line signal trend identification

    International Nuclear Information System (INIS)

    Tambouratzis, T.; Antonopoulos-Domis, M.

    2004-01-01

    An artificial neural network, based on the self-organizing map, is proposed for on-line signal trend identification. Trends are categorized at each incoming signal as steady-state, increasing and decreasing, while they are further classified according to characteristics such signal shape and rate of change. Tests with model-generated signals illustrate the ability of the self-organizing map to accurately and reliably perform on-line trend identification in terms of both detection and classification. The proposed methodology has been found robust to the presence of white noise

  13. On line routing per mobile phone

    DEFF Research Database (Denmark)

    Bieding, Thomas; Görtz, Simon; Klose, Andreas

    2009-01-01

    On-line routing is concerned with building vehicle routes in an ongoing fashion in such a way that customer requests arriving dynamically in time are efficiently and effectively served. An indispensable prerequisite for applying on-line routing methods is mobile communication technology....... Additionally it is of utmost importance that the employed communication system is suitable integrated with the firm’s enterprise application system and business processes. On basis of a case study, we describe in this paper a system that is cheap and easy to implement due to the use of simple mobile phones...

  14. On-line atomic data access

    Energy Technology Data Exchange (ETDEWEB)

    Schultz, D.R. [Oak Ridge National Lab., TN (United States); Nash, J.K. [Lawrence Livermore National Lab., CA (United States)

    1996-04-01

    The need for atomic data is one which continues to expand in a wide variety of applications including fusion energy, astrophysics, laser- produced plasma research, and plasma processing. Modern computer database and communications technology nables this data to be placed on-line and obtained by users of the Internet. Presented here is a summary of the observations and conclusions regarding such on-line atomic data access derived from a forum held at the Tenth APS Topical Conference on Atomic Processes in Plasmas.

  15. On-line monitoring for calibration reduction

    International Nuclear Information System (INIS)

    Hoffmann, Mario; Gran, Frauke Schmitt; Thunem, Harald P-J.

    2004-04-01

    On-Line Monitoring (OLM) of a channel's calibration state evaluates instrument channel performance by assessing its consistency with other plant indications. Industry and experience at several plants has shown this overall approach to be very effective in identifying instrument channels that are exhibiting degrading or inconsistent performance characteristics. The Halden Reactor Project has developed the signal validation system PEANO, which can be used to assist with the tasks of OLM. To further enhance the PEANO System for use as a calibration reduction tool, the following two additional modules have been developed; HRP Prox, which performs pre-processing and statistical analysis of signal data, Batch Monitoring Module (BMM), which is an off-line batch monitoring and reporting suite. The purpose and functionality of the HRP Prox and BMM modules are discussed in this report, as well as the improvements made to the PEANO Server to support these new modules. The Halden Reactor Project has established a Halden On-Line Monitoring User Group (HOLMUG), devoted to the discussion and implementation of on-line monitoring techniques in power plants. It is formed by utilities, vendors, regulatory bodies and research institutes that meet regularly to discuss implementation aspects of on-line monitoring, technical specification changes, cost-benefit analysis and regulatory issues. (Author)

  16. SPIRES I: on-line search guide

    International Nuclear Information System (INIS)

    Addis, L.

    1975-06-01

    SPIRES I is the first generation of the on-line Stanford Public Information Retrieval System. Designed as a prototype system, SPIRES I was later moved to the SLAC computing facility where it has been routinely available to SLAC users in the field of high-energy physics. The scope and use of the SPIRES I system are described in this manual

  17. HOPI: on-line injection optimization program

    International Nuclear Information System (INIS)

    LeMaire, J.L.

    1977-01-01

    A method of matching the beam from the 200 MeV linac to the AGS without the necessity of making emittance measurements is presented. An on-line computer program written on the PDP10 computer performs the matching by modifying independently the horizontal and vertical emittance. Experimental results show success with this method, which can be applied to any matching section

  18. Educational On-Line Gaming Propensity

    DEFF Research Database (Denmark)

    Sudzina, Frantisek; Razmerita, Liana; Kirchner, Kathrin

    2014-01-01

    Educational on-line games are promising for new generations of students who are grown up digital. Th e new generations of students are technology savvy and spend lots of time on the web and on social networks. Based on an exploratory study, this article investigates the factors that infl uence...... students’ willingness to participate in serious games for teaching/learning. Th is study investigates the relationship between students’ behavior on Facebook, Facebook games, and their attitude toward educational on-line games. Th e results of the study reveal that the early adopters of educational games...... are likely to be students, who are young, have only a few Facebook connections, who currently play Facebook game(s). Furthermore, the study emphasizes that there may be differences between students coming from various countries....

  19. Trends in on-line data processing

    International Nuclear Information System (INIS)

    Masetti, M.

    1981-01-01

    The developement of integrated circuits has been characterized by an exponential growth of gates on a single chip that will still continue in the coming years. In parallel the price per bit is dropping down with more or less the same law. As a consequence of this a few statements can be made: The present 16-bit minicomputer in a small configuration is going to be substituted by a 16-bit microcomputer, and the 16-bit microcomputer in a powerful configuration by a 32-bit midi having also a virtual memory facility. Fully programmable or microcoded powerful devices like the LASS hardware processor or MICE, will allow an efficient on-line filter. Higher computing speed can be achieved by a multiprocessor configuration which can be insensitive to hardware failures. Therefore we are moving towards an integrated on-line computing system with much higher computing power than now and the present distinction between on-line and off-line will no longer be so sharp. As more processing can be performed on-line, fast high quality feed-back can be provided for the experiment. In the years to come the trend towards more processing power, at a lower price, and assembled in the same hardware volume will continue for at least five years; at the same time the future large high-energy physics experiments at LEP will be carried out within a wide international collaboration. In this environment methods must be found for a large fraction of the work to be distributed amongst the collaborators. To accomplish this aim it is necessary to introduce common standard practices concerning both hardware and software, in such a way that the seperate parts, developed by the collaborators, will be plug-compatible. (orig.)

  20. New Trends in on-line Marketing

    OpenAIRE

    Palkovič, Lukáš

    2011-01-01

    This bachelor thesis deals with new trend of internet marketing, it focuses especially on viral marketing. The theoretical part charasterizes the process of viral campaigns, furthermore deals with the components and aspects of on-line environment. Another separated chapter presents social networks, their place in viral marketing and at last but not least the viral video making process. The practical part contains different analyses of specific viral campaigns. The next and equally the last pa...

  1. On-Line Maintenance Methodology Development

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyo Won; Kim, Jae Ho; Jae, Moo Sung [Hanyang University, Seoul (Korea, Republic of)

    2012-05-15

    Most of domestic maintenance activities for nuclear power plants are performed while overhaul. Therefore, On-Line Maintenance (OLM) is one of the proper risks informed application techniques for diffusing maintenance burden during overhaul with safety of the plant is secured. The NUMARC 93-01 (Rev.3) presents the OLM state of the art and it provides methodology. This study adopts NUMARC 93-01 (Rev.3) and present OLM. The reference component is Emergency Diesel Generator (EDG) of Ulchin 3, 4

  2. On-line neutron activation analyzers

    International Nuclear Information System (INIS)

    Flahaut, V.; Colmon, A.

    1999-01-01

    A neutronic analyser has been designed to determine the composition of the flow of raw materials entering a cement factory on the conveyor belt. This new system gives a reliable analysis of the whole cargo that outdates the sampling or the usual surface analysis based on fluorescence spectrometry. The accuracy is about 1%.The neutrons interact with the materials on an average depth of 25 cm and are absorbed by nuclei, these nuclei produce photons whose energy is characteristic of the chemical element itself. The composition can be deduced by measuring the number of photons emitted and their energy. The analysis is made on-line and can concern the search for about 10 compounds. In the case of cement the list of compounds is: SiO 2 , CaO, Al 2 O 3 , Fe 2 O 3 , MgO, Na 2 O, TiO 2 , S, Mn 2 O 3 , K 2 O, and H 2 O. The neutron generator involves a deuterium ion source whose deuterium ions are accelerated by means of an electrical field and impinge on a tritiated target, the nuclear reactions between deuterium and tritium produce 14 MeV neutrons. This neutron analysing technique can be adapted to any need of on-line composition determination. (A.C.)

  3. On line nuclear orientation: opportunity and challenge

    International Nuclear Information System (INIS)

    Stone, N.J.

    1985-01-01

    The development of the on-line nuclear orientation (OLNO) technique is reviewed. The present potential of the technique is discussed in the light of the attainable temperatures, the use of ion implantation and the required isotope flux. Limitations associated with spin-lattice relaxation are considered in some detail and a survey of accessible nuclei is presented. An outline comparison is given between OLNO and other methods for producing orientation of nuclei, for measuring nuclear spins and static moments and for the study of level structure and transition probabilities. The conclusion is drawn that the method in its present form has extensive potential over a wide range of nuclei. Future prospects for in-beam polarisation giving access to nuclei of shorter half lives are referred to briefly. (Auth.)

  4. An on-line diagnostic expert system

    International Nuclear Information System (INIS)

    Felkel, L.

    1987-01-01

    As experience with on-line information systems, experts systems and artificial intelligence tools grows, the authors retreat from the first euphoria that AI could help them solve the problem they were unable to solve with conventional programming. The major effort of the development time goes into building the knowledge-base. There is no such thing as a generic knowledge-base for nuclear power plants as there is, for example, for the diagnosis of a Boeing 747 aircraft. AI-methods, tools and hardware are still in a state which does not optimally lend itself to real-time application. The ability of developing prototype systems to investigate variants otherwise too costly to justify is one advantage that the authors gladly accept. Last, but no least the tools provide a flexible and adaptable user interface (desktop window systems) etc. The development of such tools in a project would be prohibitive and room for experimentation would be limited

  5. On-Line Algorithms and Reverse Mathematics

    Science.gov (United States)

    Harris, Seth

    In this thesis, we classify the reverse-mathematical strength of sequential problems. If we are given a problem P of the form ∀X(alpha(X) → ∃Zbeta(X,Z)) then the corresponding sequential problem, SeqP, asserts the existence of infinitely many solutions to P: ∀X(∀nalpha(Xn) → ∃Z∀nbeta(X n,Zn)). P is typically provable in RCA0 if all objects involved are finite. SeqP, however, is only guaranteed to be provable in ACA0. In this thesis we exactly characterize which sequential problems are equivalent to RCA0, WKL0, or ACA0.. We say that a problem P is solvable by an on-line algorithm if P can be solved according to a two-player game, played by Alice and Bob, in which Bob has a winning strategy. Bob wins the game if Alice's sequence of plays 〈a0, ..., ak〉 and Bob's sequence of responses 〈 b0, ..., bk〉 constitute a solution to P. Formally, an on-line algorithm A is a function that inputs an admissible sequence of plays 〈a 0, b0, ..., aj〉 and outputs a new play bj for Bob. (This differs from the typical definition of "algorithm", though quite often a concrete set of instructions can be easily deduced from A.). We show that SeqP is provable in RCA0 precisely when P is solvable by an on-line algorithm. Schmerl proved this result specifically for the graph coloring problem; we generalize Schmerl's result to any problem that is on-line solvable. To prove our separation, we introduce a principle called Predictk(r) that is equivalent to -WKL0 for standard k, r.. We show that WKL0 is sufficient to prove SeqP precisely when P has a solvable closed kernel. This means that a solution exists, and each initial segment of this solution is a solution to the corresponding initial segment of the problem. (Certain bounding conditions are necessary as well.) If no such solution exists, then SeqP is equivalent to ACA0 over RCA 0 + ISigma02; RCA0 alone suffices if only sequences of standard length are considered. We use different techniques from Schmerl to prove

  6. Software for on-line experiments

    International Nuclear Information System (INIS)

    Ivanchenko, I.M.

    1981-01-01

    A review of nowadays development state of software of on-line electron experiments is presented. The principles of organization of real time systems on second generation computer base are considered. The following methods for projections search are considered: combinator methods, global methods, methods of tracking, methods of a supporting band. The following methods for determining parameter estimates based on the Lorentz equation are analysed: analytical simulation of trajectories, determination of parameters by the iterative method using the technique of calculation of recycled integrals, multidimensional statistical analysis. For the purpose of successful usage and development of software the technique of selfdocumented programs is created and the computer is applied for preparing, revising and circulation of external descriptions which as program complexes are constructed according to the hierarchical principle [ru

  7. On line protection systems for induction motors

    International Nuclear Information System (INIS)

    Colak, I.; Celik, H.; Sefa, I.; Demirbas, S.

    2005-01-01

    Protection of induction motors is very important since they are widely used in industry for many applications due to their high robustness, reliability, low cost and maintenance, high efficiency and long service life. So, protecting these motors is crucial for operations. This paper presents a combined protection approach for induction motors. To achieve this, the electrical values of the induction motor were measured with sensitivity ±1% through a data acquisition card and processed with software developed in Visual C++. An on line protection system for induction motors was achieved easily and effectively. The experimental results have shown that the induction motor was protected against the possible problems faced during the operation. The software developed for this protection provides flexible and reliable media for operators and their motors. It is expected that the motor protection achieved in this study might be faster than the classical techniques and also may be applied to larger motors easily after small modifications of the software

  8. Aprender a innovar: una experiencia on line

    Directory of Open Access Journals (Sweden)

    Joaquín MORENO MARCHAL

    2014-11-01

    Full Text Available La creatividad y la innovación se han convertido en recursos clave en la denominada sociedad del conocimiento, que bien podría ser también llamada sociedad de la innovación. Pero innovar es una actividad compleja, que integra la aplicación de múltiples capacidades, el pensamiento divergente y convergente, la gestión de equipos humanos, la comunicación. Ahora bien, a innovar se puede, y se debe, aprender. Aprender a innovar es un reto y también una obligación para el conjunto del sistema educativo en todos sus niveles. Partiendo de estas consideraciones este trabajo expone una experiencia de aprendizaje de la creatividad y de la innovación a través de un curso totalmente on line basado en la plataforma MOODLE, en el marco del Programa de Formación Permanente de la Universidad de Cádiz. Se presenta un modelo del proceso de innovación, denominado CREALAB, de elaboración propia. Este modelo se ha utilizado como base del proceso de aprendizaje de la creatividad y de la innovación y en el diseño del curso, está organizado en torno a actividades y tiene un carácter iterativo y realimentado. Se presentan además el conjunto del diseño metodológico y los resultados obtenidos en las dos ediciones celebradas hasta el momento. El diseño del curso totalmente on line y los resultados alcanzados permiten estimar un alto potencial de aplicación, tanto a nivel personal como a nivel organizacional.

  9. Atmospheric pressure photoionization for enhanced compatibility in on-line micellar electrokinetic chromatography-mass spectrometry

    NARCIS (Netherlands)

    Mol, Roelof; De Jong, Gerhardus J.; Somsen, Govert W.

    2005-01-01

    Atmospheric pressure photoionization (APPI) is presented as a novel means for the combination of micellar electrokinetic chromatography (MEKC) and mass spectrometry (MS). The on-line coupling is achieved using an adapted sheath flow interface installed on an orthogonal APPI source. Acetone or

  10. Antioxidants in Raspberry: On-line analysis links antioxidant activity to a diversity of individual metabolites

    NARCIS (Netherlands)

    Beekwilder, M.J.; Jonker, H.H.; Hall, R.D.; Meer, van der I.M.; Vos, de C.H.

    2005-01-01

    The presence of antioxidant compounds can be considered as a quality parameter for edible fruit. In this paper, we studied the antioxidant compounds in raspberry (Rubus idaeus) fruits by high-performance liquid chromatography (HPLC) coupled to an on-line postcolumn antioxidant detection system. Both

  11. On-line maintenance at Cofrentes NPP

    International Nuclear Information System (INIS)

    Roldan Vilches, J.; Moreno Matarranz, M. A.; Hermana Mendioroz, I.

    1998-01-01

    Cofrentes NPP has begun in 1997 activities related to At Power Preventive Maintenance over trains or systems which lead to a voluntary entry in a Limitative Condition of Operation (LCO) of the Technical Specifications. From others benefits, this program ha improved the risk management and the staff's knowledge over the functions and safety implications of the different systems, the better exploit of the resources, the co-ordination of the different organisations involved (Maintenance an Operation) and the reductions of works during shutdowns. Previous to each work, a feasibility study analyzes qualitative and quantitative (PSA), using the Risk Monitor, the implications on safety of all the tasks, assuring that the global safety of the Plant is always maintained. Tech. Spec. are analyzed in detail and also are analyzed situations of simultaneous unavailabilities of systems which could lead to a high risk situation. Two different risk controls are defined (punctual and accumulated) to assure that high risk situations will not be given. Finally, historical risk profile is analyzed to assure that the accumulated risk increase is not significant. Risk Monitor helps staff in the schedule and follow-up of the activities of On-Line Maintenance. Each one of the tasks are deeply planned and harshly analyzed and are carried out by high qualified workers. By the moment, this program is running with fully satisfaction on the Plant. (Author)

  12. SOL: INNOVACIÓN ON-LINE

    Directory of Open Access Journals (Sweden)

    Rubén Faúndez

    2007-11-01

    Full Text Available Las aplicaciones de simulación tienden a ser cada vez más cercanas a usuarios e industrias. Sin embargo, muchas de ellas no poseen ni la capacidad ni el conocimiento como para desarrollar internamente sus modelos de simulación. Por este motivo, y como una forma de apoyar la toma de decisiones basándose en modelos de simulación, se presenta la plataforma SOL (Simulación On Line. La metodología completa de trabajo, así como la interacción entre SOL, Empresa y Asesor, son presentadas. Su base de datos, los niveles de usuarios, sus funcionalidades, y la creación automatizada de información grafica y visual, también son explicadas. En el caso de aplicación, el uso de SOL para apoyar la toma de decisiones en una operación de movimiento de material, permite a los tomadores de decisión acceder a análisis robustos basados en información extraída de los modelos de simulación. SOL, al almacenar información, funcionar vía web, generar análisis automatizados y crear visualizaciones, permite cumplir con las expectativas de los usuarios respecto a una solución integral en simulación.

  13. Simplified automatic on-line document searching

    International Nuclear Information System (INIS)

    Ebinuma, Yukio

    1983-01-01

    The author proposed searching method for users who need not-comprehensive retrieval. That is to provide flexible number of related documents for the users automatically. A group of technical terms are used as search terms to express an inquiry. Logical sums of the terms in the ascending order of frequency of the usage are prepared sequentially and automatically, and then the search formulas, qsub(m) and qsub(m-1) which meet certain threshold values are selected automatically also. Users justify precision of the search output up to 20 items retrieved by the formula qsub(m). If a user wishes more than 30% of recall ratio, the serach result should be output by qsub(m), and if he wishes less than 30% of it, it should be output by qsub(m-1). The search by this method using one year volume of INIS Database (76,600 items) and five inquiries resulted in 32% of recall ratio and 36% of precision ratio on the average in the case of qsub(m). The connecting time of a terminal was within 15 minutes per an inquiry. It showed more efficiency than that of an inexperienced searcher. The method can be applied to on-line searching system for database in which natural language only or natural language and controlled vocabulary are used. (author)

  14. On-Line Impact Load Identification

    Directory of Open Access Journals (Sweden)

    Krzysztof Sekuła

    2013-01-01

    Full Text Available The so-called Adaptive Impact Absorption (AIA is a research area of safety engineering devoted to problems of shock absorption in various unpredictable scenarios of collisions. It makes use of smart technologies (systems equipped with sensors, controllable dissipaters and specialised tools for signal processing. Examples of engineering applications for AIA systems are protective road barriers, automotive bumpers or adaptive landing gears. One of the most challenging problems for AIA systems is on-line identification of impact loads, which is crucial for introducing the optimum real-time strategy of adaptive impact absorption. This paper presents the concept of an impactometer and develops the methodology able to perform real-time impact load identification. Considered dynamic excitation is generated by a mass M1 impacting with initial velocity V0. An analytical formulation of the problem, supported with numerical simulations and experimental verifications is presented. Two identification algorithms based on measured response of the impacted structure are proposed and discussed. Finally, a concept of the AIA device utilizing the idea of impactometer is briefly presented.

  15. Application of on-line analytical processing technique in accelerator

    International Nuclear Information System (INIS)

    Xie Dong; Li Weimin; He Duohui; Liu Gongfa; Xuan Ke

    2005-01-01

    A method of application of the on-line analytical processing technique in accelerator is described, which includes data pre-processing, the process of constructing of data warehouse and on-line analytical processing. (authors)

  16. Simultaneous Determination of Palladium and Platinum by On-line ...

    African Journals Online (AJOL)

    NJD

    using high performance liquid chromatography equipped with an on-line enrichment technique. Prior to ... The on-line enrichment system (Waters Corporation, USA) that was ... Using an appropriate volume (industrial plant effluents 20 mL,.

  17. Influence of visualization on consumption during on-line shopping

    OpenAIRE

    Hictaler, Urška

    2013-01-01

    This diploma work studies the influence of visualization on consumption during on-line shopping. The first part of the thesis starts with key areas of visualization, consumption and on-line shopping. Visualization, areas of use, human perception and ways of product presentation in on-line shops are defined discussed first. Next, consumption, consumers and factors that influence their decisions and satisfaction are defined. The last topic in the first part of the thesis discusses on-line shopp...

  18. A Distributed System for Learning Programming On-Line

    Science.gov (United States)

    Verdu, Elena; Regueras, Luisa M.; Verdu, Maria J.; Leal, Jose P.; de Castro, Juan P.; Queiros, Ricardo

    2012-01-01

    Several Web-based on-line judges or on-line programming trainers have been developed in order to allow students to train their programming skills. However, their pedagogical functionalities in the learning of programming have not been clearly defined. EduJudge is a project which aims to integrate the "UVA On-line Judge", an existing…

  19. Coupling sequential injection on-line preconcentration by means of a renewable microcolumn with ion-exchange beads with detection by electrothermal atomic absorption spectrometry. Comparing the performance of eluting the loaded beads with transporting them directly into the graphite tube

    DEFF Research Database (Denmark)

    Wang, Jianhua; Hansen, Elo Harald

    2001-01-01

    The design of a flow injection/sequential injection (FIA/SIA) on-line preconcentration system incorporating a renewable microcolumn with ion-exchange beads and interfaced with an electrothermal atomic absorption spectrometry (ETAAS) detector is described, and its practical applicability.......4% for the procedure in which the loaded beads are transported directly to the graphite furnace for pyrolysis and atomization, and even improved in comparison to the traditional unidirectional and bidirectional repetitive elution procedures which under comparable conditions yield R.S.D.-values of 5.8 and 4...

  20. Robust on-line monitoring of biogas processes; Robusta maettekniker on-line foer optimerad biogasproduktion

    Energy Technology Data Exchange (ETDEWEB)

    Nordberg, Aake; Hansson, Mikael; Kanerot, Mija; Krozer, Anatol; Loefving, Bjoern; Sahlin, Eskil

    2010-03-15

    Although demand for biomethane in Sweden is higher than ever, many Swedish codigestion plants are presently operated below their designed capacity. Efforts must be taken to increase the loading rate and guarantee stable operation and high availability of the plants. There are currently no commercial systems for on-line monitoring, and due to the characteristics of the material, including corrosion and tearing, robust applications have to be developed. The objective of this project was to identify and study different monitoring technologies with potential for on-line monitoring of both substrate mixtures and anaerobic digester content. Based on the prerequisites and demands at Boraas Energi och Miljoe AB's (BEMAB, the municipal energy and waste utility in the city of Boraas, Sweden) biogas plant, the extent of the problems, measurement variables and possible ways of managing these issues have been identified and prioritized. The substrate mixtures in question have a high viscosity and are inhomogeneous with variation in composition, which calls for further homogenization, dilution and filtration to achieve high precision in the necessary analyses. Studies of using different mixers and mills showed that the particle size (800 mum) needed for on-line COD measurement could not be achieved. The problem of homogenization can be avoided if indirect measurement methods are used. Laboratory tests with NIR (near-infra red spectroscopy) showed that VS can be predicted (R2=0,78) in the interval of 2-9% VS. Furthermore, impedance can give a measurement of soluble components. However, impedance is not sensitive enough to give a good measurement of total TS. Microwave technology was installed at the production plant and showed a faster response to changes in TS than the existing TS-sensor. However, due to technical problems, the evaluation only could be done during a limited period of ten days. BEMAB will continue the measurements and evaluation of the instrument. The

  1. The on-line low temperature nuclear orientation facility NICOLE

    International Nuclear Information System (INIS)

    Ohtsubo, T; Roccia, S; Gaulard, C; Stone, N J; Stone, J R; Köster, U; Nikolov, J; Veskovic, M; Simpson, G S

    2017-01-01

    We review major experiments and results obtained by the on-line low temperature nuclear orientation method at the NICOLE facility at ISOLDE, CERN since the year 2000 and highlight their general physical impact. This versatile facility, providing a large degree of controlled nuclear polarization, was used for a long-standing study of magnetic moments at shell closures in the region Z  = 28, N  = 28–50 but also for dedicated studies in the deformed region around A  ∼ 180. Another physics program was conducted to test symmetry in the weak sector and constrain weak coupling beyond V–A . Those two programs were supported by careful measurements of the involved solid state physics parameters to attain the full sensitivity of the technique and provide interesting interdisciplinary results. Future plans for this facility include the challenging idea of measuring the beta–gamma–neutron angular distributions from polarized beta delayed neutron emitters, further test of fundamental symmetries and obtaining nuclear structure data used in medical applications. The facility will also continue to contribute to both the nuclear structure and fundamental symmetry test programs. (paper)

  2. DOE-EPRI On-Line Monitoring Implementation Guidelines

    International Nuclear Information System (INIS)

    E. Davis, R. Bickford

    2003-01-01

    Industry and EPRI experience at several plants has shown on-line monitoring to be very effective in identifying out-of-calibration instrument channels or indications of equipment-degradation problems. The EPRI implementation project for on-line monitoring has demonstrated the feasibility of on-line monitoring at several participating nuclear plants. The results have been very encouraging, and substantial progress is anticipated in the coming years

  3. Algorithms for the on-line travelling salesman

    NARCIS (Netherlands)

    Ausiello, G.; Feuerstein, E.; Leonardi, S.; Stougie, L.; Talamo, M.

    1999-01-01

    In this paper the problem of efficiently serving a sequence of requests presented in an on-line fashion located at points of a metric space is considered. We call this problem the On-Line Travelling Salesman Problem (OLTSP). It has a variety of relevant applications in logistics and robotics. We

  4. An algorithm for on-line price discrimination

    NARCIS (Netherlands)

    D.D.B. van Bragt; D.J.A. Somefun (Koye); E. Kutschinski; J.A. La Poutré (Han)

    2002-01-01

    textabstractThe combination of on-line dynamic pricing with price discrimination can be very beneficial for firms operating on the Internet. We therefore develop an on-line dynamic pricing algorithm that can adjust the price schedule for a good or service on behalf of a firm. This algorithm (a

  5. On-Line Voltage Stability Assessment based on PMU Measurements

    DEFF Research Database (Denmark)

    Garcia-Valle, Rodrigo; P. Da Silva, Luiz C.; Nielsen, Arne Hejde

    2009-01-01

    This paper presents a method for on-line monitoring of risk voltage collapse based on synchronised phasor measurement. As there is no room for intensive computation and analysis in real-time, the method is based on the combination of off-line computation and on-line monitoring, which are correlat...

  6. From Off-line to On-line Handwriting Recognition

    NARCIS (Netherlands)

    Lallican, P.; Viard-Gaudin, C.; Knerr, S.

    2004-01-01

    On-line handwriting includes more information on time order of the writing signal and on the dynamics of the writing process than off-line handwriting. Therefore, on-line recognition systems achieve higher recognition rates. This can be concluded from results reported in the literature, and has been

  7. On-line Learning of Prototypes and Principal Components

    NARCIS (Netherlands)

    Biehl, M.; Freking, A.; Hölzer, M.; Reents, G.; Schlösser, E.; Saad, David

    1998-01-01

    We review our recent investigation of on-line unsupervised learning from high-dimensional structured data. First, on-line competitive learning is studied as a method for the identification of prototype vectors from overlapping clusters of examples. Specifically, we analyse the dynamics of the

  8. On-line and bulk analysis for the resource industries

    International Nuclear Information System (INIS)

    Lim, C.S.; Sowerby, B.D.; Tickner, J.R.; Madsen, I.C.

    2001-01-01

    Nuclear techniques are the basis of many CSIRO on-line and bulk analysis systems that are now widely used in the mineral and energy industries. The continuous analysis and rapid response of these systems have led to improved control of mining, processing and blending operations. This paper reviews recent developments in neutron, gamma-ray and X-ray techniques for on-line and bulk analysis by CSIRO Minerals including neutron techniques for the on-conveyor belt determination of the composition of cement raw meal, the on-line analysis of composition in pyrometallurgical applications, the on-conveyor belt determination of ash in coal, and the rapid and accurate determination of gold in bulk laboratory samples. The paper also discusses a new gamma-ray technique for the on-line determination of ash in coal and the application of X-ray diffraction techniques for the on-line determination of mineralogy in the cement industry

  9. Reducing BWR O and M costs through on-line performance monitoring

    International Nuclear Information System (INIS)

    Jonas, T.; Gross, R.; Logback, F.; Josyula, R.

    1995-01-01

    Competition in the electric power industry has placed significant emphasis on reducing operating and maintenance (O and M) costs at nuclear facilities. Therefore, on-line performance monitoring to locate power losses for boiling water reactor (BWR) plants is creating tremendous interest. In addition, the ability to automate activities such as data collection, analysis, and reporting increases the efficiency of plant engineers and gives them more time to concentrate on solving plant efficiency problems. This capability is now available with a unique software product called GEBOPS. GE Nuclear Energy, in conjunction with Joint Venture partner Black and Veatch, has undertaken development of the General Electric/Black and Veatch On-line Performance System (GEBOPS), an on-line performance monitoring system for BWR plants. The experience and expertise of GE Nuclear Energy with BWR plants, coupled with the proven on-line monitoring software development experience and capability of Black and Veatch, provide the foundation for a unique product which addresses the needs of today's BWR plants

  10. Understanding on-line community: the affordances of virtual space

    Directory of Open Access Journals (Sweden)

    Karen Ruhleder

    2002-01-01

    Full Text Available Increasing numbers of on-line venues for learning are emerging as virtual communities become more accessible and commonplace. This paper looks at one particular virtual community, an on-line degree programme at the University of Illinois, Urbana-Champaign, which offers an M.S. in Library and Information Science (called LEEP. It draws on a framework presented by Mynatt, et al. (1998, which provides a lens for talking about on-line community as a set of affordances. This framework is applied to illustrate the interactions, artefacts, and expectations that shape this community.

  11. An Approach to On-line Risk Assessment in NPP

    International Nuclear Information System (INIS)

    Simic, Z.; Mikulicic, V.; O'Brien, J.

    1996-01-01

    Probabilistic Risk Assessment (PRA) can provide safety status information for a plant during different configurations; additional effort is needed to do this in real time for on-line operation. This paper describes an approach to use PRA to achieve these goals. A Risk Assessment On-Line (RAOL) application was developed to monitor maintenance (on-line and planned) activities. RAOL is based on the results from a full-scope PRA, engineering/operational judgment and incorporates a user friendly program interface approach. Results from RAOL can be used by planners or operations to effectively manage the level of risk by controlling the actual plant configuration. (author)

  12. On-line spectroscopy with thermal atomic beams

    International Nuclear Information System (INIS)

    Thibault, C.; Guimbal, P.; Klapisch, R.; Saint Simon, M. de; Serre, J.M.; Touchard, F.; Duong, H.T.; Jacquinot, P.; Juncar, P.

    1981-01-01

    On-line high resolution laser spectroscopy experiments have been performed in which the light from a cw tunable dye laser interacts at right angles with a thermal atomic beam. sup(76-98)Rb, sup(118-145)Cs and sup(208-213)Fr have been studied using the ionic beam delivered by the ISOLDE on-line mass separator at CERN while sup(20-31)Na and sup(38-47)K have been studied by setting the apparaturs directly on-line with the PS 20 GeV proton beam. The principle of the method is briefly explained and some results concerning nuclear structure are given. (orig.)

  13. Comparison of On-Line Maintenance Support Tools

    International Nuclear Information System (INIS)

    Simic, Z.; Follen, S. M.; Mikulicic, V.

    1998-01-01

    Modeling approach to on-line risk monitoring is today in a rapid developing phase. For that reason number of different solutions are available. This paper will attempt to present existing approaches to address on-line risk modeling problem Starting with description of on-line risk monitoring issues in general, then following by presentation of existing software tools (EPRI's Safety Monitor, Equipment Out of Service Monitor, and ORAM-SENTINEL) the current state of the art in this area will be demonstrated. Finally, conclusions and ideas will be outlined. (author)

  14. Microfluidic electrochemical sensor for on-line monitoring of aerosol oxidative activity.

    Science.gov (United States)

    Sameenoi, Yupaporn; Koehler, Kirsten; Shapiro, Jeff; Boonsong, Kanokporn; Sun, Yele; Collett, Jeffrey; Volckens, John; Henry, Charles S

    2012-06-27

    Particulate matter (PM) air pollution has a significant impact on human morbidity and mortality; however, the mechanisms of PM-induced toxicity are poorly defined. A leading hypothesis states that airborne PM induces harm by generating reactive oxygen species in and around human tissues, leading to oxidative stress. We report here a system employing a microfluidic electrochemical sensor coupled directly to a particle-into-liquid sampler (PILS) system to measure aerosol oxidative activity in an on-line format. The oxidative activity measurement is based on the dithiothreitol (DTT) assay, where, after being oxidized by PM, the remaining reduced DTT is analyzed by the microfluidic sensor. The sensor consists of an array of working, reference, and auxiliary electrodes fabricated in a poly(dimethylsiloxane)-based microfluidic device. Cobalt(II) phthalocyanine-modified carbon paste was used as the working electrode material, allowing selective detection of reduced DTT. The electrochemical sensor was validated off-line against the traditional DTT assay using filter samples taken from urban environments and biomass burning events. After off-line characterization, the sensor was coupled to a PILS to enable on-line sampling/analysis of aerosol oxidative activity. Urban dust and industrial incinerator ash samples were aerosolized in an aerosol chamber and analyzed for their oxidative activity. The on-line sensor reported DTT consumption rates (oxidative activity) in good correlation with aerosol concentration (R(2) from 0.86 to 0.97) with a time resolution of approximately 3 min.

  15. On-line methanol sensor system development for recombinant ...

    African Journals Online (AJOL)

    On-line methanol sensor system development for recombinant human serum ... of the methanol sensor system was done in a medium environment with yeast cells ... induction at a low temperature and a pH where protease does not function.

  16. On-line control systems in power plants

    International Nuclear Information System (INIS)

    Freymeyer, P.

    1981-01-01

    This report is a review of on-line control systems as a complex system connected with all problems like, development, planning, degree of automation, economics, service, quality and documentation. (orig.) [de

  17. Why do People Stop Playing On-Line Games?

    DEFF Research Database (Denmark)

    Sudzina, Frantisek; Razmerita, Liana

    2012-01-01

    The recent initial public offering of shares of Zynga, probably the most important on-line game provider, drew interest of potential investors but also of general public to their business model. What the most interested people learned so far is that if Zynga had not changed their accounting...... practice, they would be in red numbers for several months already. This is most likely caused by people stopping to play their games. This paper provides an estimate of what proportion of people, who played on-line games, already stopped playing them. Additionally, it analyzed the reasons why people...... stopped playing on-line games. It also compares Facebook and other on-line games....

  18. Volume overload cleanup: An approach for on-line SPE-GC, GPC-GC, and GPC-SPE-GC

    NARCIS (Netherlands)

    Kerkdijk, H.; Mol, H.G.J.; Nagel, B. van der

    2007-01-01

    A new concept for cleanup, based on volume overloading of the cleanup column, has been developed for on-line coupling of gel permeation chromatography (GPC), solid-phase extraction (SPE), or both, to gas chromatography (GC). The principle is outlined and the applicability demonstrated by the

  19. The Daresbury On-Line Isotope Separator (DOLIS)

    International Nuclear Information System (INIS)

    Grant, I.S.; Eastham, D.A.; Groves, J.; Tolfree, D.W.L.; Walker, P.M.; Green, V.R.; Rikovska, J.; Stone, N.J.; Hamilton, W.D.

    1987-01-01

    The isotope separator DOLIS, which is on-line to the Daresbury Laboratory's 20-MV tandem accelerator, is used to measure nuclear moments and decay schemes. Separated beams may be collected on a tape and transported to a counting station, implanted directly into a host lattice at on-line temperatures down to less than 10 mK, or allowed to interact with a collinear laser beam. The present status of DOLIS and its ancillary equipment is described

  20. The Daresbury on-line isotope separator (DOLIS)

    International Nuclear Information System (INIS)

    Grant, I.S.; Eastham, D.A.; Groves, J.; Tolfree, D.W.L.; Walker, P.M.; Green, V.R.; Rikovska, J.; Stone, N.J.; Hamilton, W.D.

    1987-01-01

    The isotope separator DOLIS, which is on-line to the Daresbury Laboratory's 20-MV tandem accelerator, is used to measure nuclear moments and decay schemes. Separated beams may be collected on a tape and transported to a counting station, implanted directly into a host lattice at on-line temperatures down to less than 10 mK, or allowed to interact with a collinear laser beam. The present status of DOLIS and its ancillary equipment is described. (orig.)

  1. Considerations in applying on-line IC techniques to BWR's

    International Nuclear Information System (INIS)

    Kaleda, R.J.

    1992-01-01

    Ion-Chromatography (IC) has moved from its traditional role as a laboratory analytical tool to a real time, dynamic, on-line measurement device to follow ppb and sub-ppb concentrations of deleterious impurities in nuclear power plants. Electric Power Research Institute (EPRI), individual utilities, and industry all have played significant roles in effecting the transition. This paper highlights considerations and the evolution in current on-line Ion Chromatography systems. The first applications of on-line techniques were demonstrated by General Electric (GE) under EPRI sponsorship at Rancho Seco (1980), Calvert Cliffs, and McGuire nuclear units. The primary use was for diagnostic purposes. Today the on-line IC applications have been expanded to include process control and routine plant monitoring. Current on-line IC's are innovative in design, promote operational simplicity, are modular for simplified maintenance and repair, and use field-proven components which enhance reliability. Conductivity detection with electronic or chemical suppression and spectrometric detection techniques are intermixed in applications. Remote multi-point sample systems have addressed memory effects. Early applications measured ionic species in the part per billion range. Today reliable part per trillion measurements are common for on-line systems. Current systems are meeting the challenge of EPRI guideline requirements. Today's on-line IC's, with programmed sampling systems, monitor fluid streams throughout a power plant, supplying data that can be trended, stored and retrieved easily. The on-line IC has come of age. Many technical challenges were overcome to achieve today's IC

  2. On-line mixture-based alternative to logistic regression

    Czech Academy of Sciences Publication Activity Database

    Nagy, Ivan; Suzdaleva, Evgenia

    2016-01-01

    Roč. 26, č. 5 (2016), s. 417-437 ISSN 1210-0552 R&D Projects: GA ČR GA15-03564S Institutional support: RVO:67985556 Keywords : on-line modeling * on-line logistic regression * recursive mixture estimation * data dependent pointer Subject RIV: BB - Applied Statistics, Operational Research Impact factor: 0.394, year: 2016 http://library.utia.cas.cz/separaty/2016/ZS/suzdaleva-0464463.pdf

  3. The on-line mass separator SIRIUS at the Strasbourg Reactor

    International Nuclear Information System (INIS)

    Zirnheld, J.P.; Schutz, L.

    1979-01-01

    The SIRIUS facility was developed to isolate short-lived neutron-rich nuclides far from the line of β stability. The installation, which consists of a helium-jet fission-product transport system, an ion source, an accelerator and a deviation magnet, is described. The main characteristics of the whole system can be summarized as: (1) the fission-product transmission to the ion source is about 90%: (2) the mass resolving power is of the order of 500: (3) the total transit time between production and detection is less than 1s : (4) the overall efficiency of the system is on the average better than 5x10 -5 . The nuclei available for nuclear spectroscopic studies have been examined. With a neutron flux of 5x10 11 /cm 2 .s and 730 mg for the uranium target, about 50 neutron-rich rare-earth isotopes (many of which had previously been unavailable) are available with sufficient activities for nuclear spectroscopic studies. (Auth.)

  4. On-line supercritical fluid extraction-supercritical fluid chromatography-mass spectrometry of polycyclic aromatic hydrocarbons in soil.

    Science.gov (United States)

    Wicker, A Paige; Carlton, Doug D; Tanaka, Kenichiro; Nishimura, Masayuki; Chen, Vivian; Ogura, Tairo; Hedgepeth, William; Schug, Kevin A

    2018-06-01

    On-line supercritical fluid extraction - supercritical fluid chromatography - mass spectrometry (SFE-SFC-MS) has been applied for the determination of polycyclic aromatic hydrocarbons (PAHs) in soil. The purpose of this study was to develop and validate the first on-line SFE-SFC-MS method for the quantification of PAHs in various types of soil. By coupling the sample extraction on-line with chromatography and detection, sample preparation is minimized, diminishing sample loss and contamination, and significantly decreasing the required extraction time. Parameters for on-line extraction coupled to chromatographic analysis were optimized. The method was validated for concentrations of 10-1500 ng of PAHs per gram of soil in Certified Reference Material (CRM) sediment, clay, and sand with R 2  ≥ 0.99. Limits of detection (LOD) were found in the range of 0.001-5 ng/g, and limits of quantification (LOQ) in the range of 5-15 ng/g. The method developed in this study can be effectively applied to the study of PAHs in the environment, and may lay the foundation for further applications of on-line SFE-SFC-MS. Copyright © 2018 Elsevier B.V. All rights reserved.

  5. On-line maintenance PSA support at NPP Krsko

    International Nuclear Information System (INIS)

    Prosen, R.; Vrbanic, I.; Kastelan, M.

    2000-01-01

    In 1997 Krsko NPP initiated the on-line maintenance (OLM) practice. On-line maintenance constitutes of corrective activities, preventive activities, surveillance activities, tests and inspections, as well as calibrations and modifications, taking place during the normal power operations. The on-line maintenance is a multidisciplinary process consisting of activity specification, planning, and preparation and performing of the OLM activity of interest. The primary role of the PSA group is to assess from the r isk perspective , using the plant-specific NEK PSA model, system unavailability and the impact to the plant operational risk. The intent is to support planning of the on-line maintenance activities from the risk perspective. The risk evaluation of the OLM activities is based on the probability of core damage evaluation for the defined discrete plant configuration states, determined by the OLM activities. Within this application, the optimized, plant-specific PSA model is used on Risk Spectrum platform. To perform the risk assessment of the on-line maintenance activities, first the systems to be affected are defined based on the planned OLM activities. The next important step is the assessment of the planned work schedule. To define the final schedule, the co-ordination and optimizing the planned OLM activities needs activation of all participating departments, supported also from PSA group. The P3 (i.e. Primavera) planning tool system windows are defined for different systems and groups of systems, and the activities are sorted in particular weeks according to these windows. (author)

  6. OLDASS: On-line data acquisition system at SF cyclotron

    International Nuclear Information System (INIS)

    Omata, Kazuo; Yasue, Masaharu; Hamagaki, Hideki

    1982-01-01

    The on-line data acquisition system in the Institute for Nuclear Study, the University of Tokyo, is composed of 2 systems of Fujitsu mini-computer PFU-400 for data processing at the high energy synchrotron and one system of that computer for low energy cyclotron as terminals, the host computer being M 180 II AD of the same company. This system has been developed to have the features of being the on-line system capable of following the improvement of host computer performance, being capable of developing the on-line programmes of other experimenting groups in parallel with batch jobs or the operation of the on-line system, and capable of developing programmes using FORTRAN. The result of about 220 KB/s was obtained for the data transfer rate between the programmes of the host computer and terminals, and this fulfilled the aimed performance. The terminal system on the low energy side is provided with an ADC interface and a display interface specified particularly in addition to the miniature computer PFU400 and standard I/O devices of the manufacture. The accumulating type graphic display of the I/O devices can be switched to be connected to the host computer, and immediately displays the results transferred to the host computer and analyzed. Hard copy is also available. The above hardware and software are explained. The on-line system insures 80 K bytes of the total memory of 224 K bytes for data area. (Wakatsuki, Y.)

  7. Sport Management Taught On-Line: A Discussion

    Directory of Open Access Journals (Sweden)

    William F. Stier Jr

    2009-01-01

    Full Text Available An introduction to the world of on-line courses (distance education/learning is presented. In addition, the world of on-line learning, as it pertains to sport management, is examined within the framework of (a pedagogy, (b finances,(c assessment, and (d choosing to transition from the traditional classroom to on-line learning. Pertinent points relative to each of the four categories are presented from the literature. In an effort to stimulate thought and discussion to the subject of on-line learning for sport management programs/courses the authors provide their reactions to the literature points by presenting their comments/reactions from a sport management perspective. Sport management professors and administrators are encouraged to critically examine the feasibility of such on-line courses (distance education/learning within their own curricula while maintaining an appropriate framework revolving around sound theoretical instructional strategies, methods as well as appropriate use of instructional tools, including but not limited to, computersand the WWW.

  8. Optimization of antibody immobilization for on-line or off-line immunoaffinity chromatography

    DEFF Research Database (Denmark)

    Beyer, Natascha Helena; Schou, Christian; Højrup, Peter

    2009-01-01

    -POROS. Protein G-based matrices are very stable showing essentially no decline in performance after 50 application-wash-elution-reequilibration cycles and being easily prepared within 2-3 h of working time with a typical antibody coupling yield of above 80%. In off-line applications where constant flow....... A systematic study was conducted to determine the most versatile antibody immobilization method for use in on-line and off-line IA chromatography applications using commonly accessible immobilization methods. Four chemistries were examined using polyclonal and monoclonal antibodies and antibody fragments. We...

  9. Initiating Events Modeling for On-Line Risk Monitoring Application

    International Nuclear Information System (INIS)

    Simic, Z.; Mikulicic, V.

    1998-01-01

    In order to make on-line risk monitoring application of Probabilistic Risk Assessment more complete and realistic, a special attention need to be dedicated to initiating events modeling. Two different issues are of special importance: one is how to model initiating events frequency according to current plant configuration (equipment alignment and out of service status) and operating condition (weather and various activities), and the second is how to preserve dependencies between initiating events model and rest of PRA model. First, the paper will discuss how initiating events can be treated in on-line risk monitoring application. Second, practical example of initiating events modeling in EPRI's Equipment Out of Service on-line monitoring tool will be presented. Gains from application and possible improvements will be discussed in conclusion. (author)

  10. Thermographic Sensing For On-Line Industrial Control

    Science.gov (United States)

    Holmsten, Dag

    1986-10-01

    It is today's emergence of thermoelectrically cooled, highly accurate infrared linescanners and imaging systems that has definitely made on-line Infraread Thermography (IRT) possible. Specifically designed for continuous use, these scanners are equipped with dedicated software capable of monitoring and controlling highly complex thermodynamic situations. This paper will outline some possible implications of using IRT on-line by describing some uses of this technology in the steel-making (hot rolling) and automotive industries (machine-vision). A warning is also expressed that IRT technology not originally designed for automated applications e.g. high resolution, imaging systems, should not be directly applied to an on-line measurement situation without having its measurement resolution, accuracy and especially its repeatability, reliably proven. Some suitable testing procedures are briefly outlined at the end of the paper.

  11. An on-line monitoring system for navigation equipment

    Science.gov (United States)

    Wang, Bo; Yang, Ping; Liu, Jing; Yang, Zhengbo; Liang, Fei

    2017-10-01

    Civil air navigation equipment is the most important infrastructure of Civil Aviation, which is closely related to flight safety. In addition to regular flight inspection, navigation equipment's patrol measuring, maintenance measuring, running measuring under special weather conditions are the important means of ensuring aviation flight safety. According to the safety maintenance requirements of Civil Aviation Air Traffic Control navigation equipment, this paper developed one on-line monitoring system with independent intellectual property rights for navigation equipment, the system breakthroughs the key technologies of measuring navigation equipment on-line including Instrument Landing System (ILS) and VHF Omni-directional Range (VOR), which also meets the requirements of navigation equipment ground measurement set by the ICAO DOC 8071, it provides technical means of the ground on-line measurement for navigation equipment, improves the safety of navigation equipment operation, and reduces the impact of measuring navigation equipment on airport operation.

  12. On-line calculation of 3-D power distribution

    International Nuclear Information System (INIS)

    Park, Y. H.; In, W. K.; Park, J. R.; Lee, C. C.; Auh, G. S.

    1996-01-01

    The 3-D power distribution synthesis scheme was implemented in Totally Integrated Core Operation Monitoring System (TICOMS), which is under development as the next generation core monitoring system. The on-line 3-D core power distribution obtained from the measured fixed incore detector readings is used to construct the hot pin power as well as the core average axial power distribution. The core average axial power distribution and the hot pin power of TICOMS were compared with those of the current digital on-line core monitoring system, COLSS, which construct the core average axial power distribution and the pseudo hot pin power. The comparison shows that TICOMS results in the slightly more accurate core average axial power distribution and the less conservative hot pin power. Therefore, these results increased the core operating margins. In addition, the on-line 3-D power distribution is expected to be very useful for the core operation in the future

  13. UNISOR on-line nuclear orientation facility (UNISOR/NOF)

    International Nuclear Information System (INIS)

    Girit, I.C.; Alton, G.D.; Bingham, C.R.; Carter, H.K.; Simpson, M.L.; Cole, J.D.; Croft, W.L.; Hamilton, J.H.; Jones, E.F.; Gore, P.M.; Kormicki, J.; Xie, H.; Kern, B.D.; Krane, K.S.; Xu, Y.S.; Mantica, P.F. Jr.; Zimmermann, B.E.; Nettles, W.G.; Zganjar, E.F.; Kortelahti, M.O.; Newbolt, W.B.

    1988-01-01

    The UNISOR on-line nuclear orientation facility (UNISOR/NOF) consists of a 3 He- 4 He dilution refrigerator on line to the isotope separator. Nuclei are implanted directly into a target foil which is soldered to the bottom accessed cold finger of the refrigerator. A 1.5 T superconducting magnet polarizes the ferromagnetic target foils and determines the axis of symmetry. Up to eight gamma detectors can be positioned around the refrigerator, each 9 cm from the target. A unique feature of this system is that the k=4 term in the directional distribution function can be directly and unambigously deduced so that a single solution for the mixing ratio can be found. The first on-line experiment at this facility reported here was a study of the decay of the 191 Hg and 193 Hg isotopes. (orig.)

  14. Making the most of on-line recruiting.

    Science.gov (United States)

    Cappelli, P

    2001-03-01

    Ninety percent of large U.S. companies are already recruiting via the Internet. By simply logging on to the Web, company recruiters can locate vast numbers of qualified candidates for jobs at every level, screen them in minutes, and contact the most promising ones immediately. The payoffs can be enormous: it costs substantially less to hire someone on-line, and the time saved is equally great. In this article, Peter Cappelli examines some of the emerging service providers and technologies--matchmakers, job boards, hiring management systems software, and applicant-screening mechanisms that test skills and record interests. He also looks at some of the strategies companies are adopting as they enter on-line labor markets. Recruiting needs to be refashioned to resemble marketing, he stresses. Accordingly, smart companies are designing Web pages, and even product ads, with potential recruits in mind. They're giving line managers authority to hire so that candidates in cyberspace aren't lost. They're building internal on-line job networks to retain talent. Integrating recruiting efforts with overall marketing campaigns, especially through coordination and identification with the company's brand, is the most important thing companies can do to ensure success in on-line hiring. Along the way, Cappelli sounds two cautionary notes. First, a human touch, not electronic contact, is vital in the last steps of a successful hiring process. Second, companies must make sure that on-line testing and hiring criteria do not discriminate against women, disabled people, workers over 40, or members of minority groups. When competition for talent is fierce, companies that master the art and science of on-line recruiting will be the ones that attract and keep the best people.

  15. The User-friendly On-Line Diffusion Chamber

    CERN Document Server

    Aviles Acosta, Jaime

    2015-01-01

    The On-Line Diffusion Chamber is a stand-alone apparatus built to carry out short-live radiotracer diffusion studies. The availability of the on-demand production of isotopes in the ISOLDE facility, and the design of the apparatus to streamline the implantation process, annealing treatment, ion gun ablation with a tape transport system, and radiation intensity measurement with a Ge gamma detector all in the same apparatus, gives the On-Line Diffusion Chamber a unique ability to studies with short-lived radioisotopes or isomer states that are not possible in any other facility in the world.

  16. The rationalization of desulfurization by on-line analysis

    Energy Technology Data Exchange (ETDEWEB)

    Murakami, Y; Kohmura, S; Taketomi, H; Matsumura, S; Sasaki, Y

    1986-01-01

    Nippon Kokan uses the Takahax and Sulfiban processes for the desulfurization of coke oven gas. The authors outline the Sulfiban Process and describe a recently developed system for the on-line determination of H/sub 2/S in coke oven gas, and of CO/sub 2/ and monoethanolamine (MEA) in the wash oil. This new on-line analysis system has proved effective in rationalizing the Sulfiban Process via lower MEA production costs and decreased power consumption. The introduction of a computerized control system is now being studied. 7 figs., 4 tabs.

  17. 5th Computer Science On-line Conference

    CERN Document Server

    Senkerik, Roman; Oplatkova, Zuzana; Silhavy, Petr; Prokopova, Zdenka

    2016-01-01

    This volume is based on the research papers presented in the 5th Computer Science On-line Conference. The volume Artificial Intelligence Perspectives in Intelligent Systems presents modern trends and methods to real-world problems, and in particular, exploratory research that describes novel approaches in the field of artificial intelligence. New algorithms in a variety of fields are also presented. The Computer Science On-line Conference (CSOC 2016) is intended to provide an international forum for discussions on the latest research results in all areas related to Computer Science. The addressed topics are the theoretical aspects and applications of Computer Science, Artificial Intelligences, Cybernetics, Automation Control Theory and Software Engineering.

  18. Comparison of Current On-line Payment Technologies

    OpenAIRE

    Mandadi, Ravi

    2006-01-01

    The purpose of this thesis work was to make a survey of current on-line payment technologies and find out which are they and how do they work? Compare and analyze them from a security point of view, as well as a usability point of view. What is good? What is bad? What is lacking? To achieve this purpose, an overview of the current on-line payment technologies was acquired through academic books and papers, Internet sites, magazines. Basic cryptographic and security related techniques were stu...

  19. An on-line adaptive core monitoring system

    International Nuclear Information System (INIS)

    Verspeek, J.A.; Bruggink, J.C.; Karuza, J.

    1997-01-01

    An on-line core monitoring system has been in operation for three years in the Dodewaard Nuclear Power Plant. The core monitor uses the on-line measured reactor data as an input for a power distribution calculation. The measurements are frequently performed. The system is used for monitoring as well as for predicting purposes. The limiting thermal hydraulic parameters are monitored as well as the pellet-clad interaction limits. The data are added to a history file used for cycle burn-up calculations and trending of parameters. The reactor states are presented through a convenient graphical user interface. (authors)

  20. On-Line Generation of 3D-Waves

    DEFF Research Database (Denmark)

    Frigaard, Peter

    1992-01-01

    The paper describes the technique of filtering white noise for on-line generation of 3D-waves on a small computer in the laboratory. The wave generation package is implemented and tested in the 3D-wave basin at the University of Aalborg.......The paper describes the technique of filtering white noise for on-line generation of 3D-waves on a small computer in the laboratory. The wave generation package is implemented and tested in the 3D-wave basin at the University of Aalborg....

  1. Comparing the happiness effects of real and on-line friends.

    Directory of Open Access Journals (Sweden)

    John F Helliwell

    Full Text Available A recent large Canadian survey permits us to compare face-to-face ('real-life' and on-line social networks as sources of subjective well-being. The sample of 5,000 is drawn randomly from an on-line pool of respondents, a group well placed to have and value on-line friendships. We find three key results. First, the number of real-life friends is positively correlated with subjective well-being (SWB even after controlling for income, demographic variables and personality differences. Doubling the number of friends in real life has an equivalent effect on well-being as a 50% increase in income. Second, the size of online networks is largely uncorrelated with subjective well-being. Third, we find that real-life friends are much more important for people who are single, divorced, separated or widowed than they are for people who are married or living with a partner. Findings from large international surveys (the European Social Surveys 2002-2008 are used to confirm the importance of real-life social networks to SWB; they also indicate a significantly smaller value of social networks to married or partnered couples.

  2. Integrated sensor array for on-line monitoring micro bioreactors

    NARCIS (Netherlands)

    Krommenhoek, E.E.

    2007-01-01

    The “Fed��?batch on a chip��?��?project, which was carried out in close cooperation with the Technical University of Delft, aims to miniaturize and parallelize micro bioreactors suitable for on-line screening of micro-organisms. This thesis describes an electrochemical sensor array which has been

  3. On-Line Pesticide Training with Narrated Powerpoint Presentations

    Science.gov (United States)

    Johnson, Steven B.

    2015-01-01

    UMaine Cooperative Extension is the primary educational delivery organization for pesticide recertification credits in Maine. Shrinking budgets and staff numbers are making traditional face-to-face delivery increasingly difficult to maintain. To address this issue, on-line pesticide applicator recertification training credits were developed. The…

  4. Personality Interactions and Scaffolding in On-Line Discussions

    Science.gov (United States)

    Nussbaum, E. Michael; Hartley, Kendall; Sinatra, Gale M.; Reynolds, Ralph E.; Bendixen, Lisa D.

    2004-01-01

    The potential of on-line discussions to prompt greater reflection of course material is often stymied by a tendency of students to agree with one another rather than to formulate counter-arguments. This article describes an experiment using note starters and elaborated cases to encourage counter-argumentation and examines interactions with…

  5. A new electrostatic on-line collection-system

    International Nuclear Information System (INIS)

    Dufour, J.P.; Del Moral, R.; Fleury, A.; Hubert, F.; Llabador, Y.; Mauhourat, M.B.; Bimbot, R.; Gardes, D.; Rivet, M.F.

    1981-01-01

    The working conditions of a new on-line electrostatic collection system are presented. The main characteristics are high efficiency (reaching 20%) and short delay time (down to the millisecond). The salient features of specific devices for measurements of absolute cross sections, recoil range distributions and angular distributions are given. (orig.)

  6. Specialization processes in on-line unsupervised learning

    NARCIS (Netherlands)

    Biehl, M.; Freking, A.; Reents, G.; Schlösser, E.

    1998-01-01

    From the recent analysis of supervised learning by on-line gradient descent in multilayered neural networks it is known that the necessary process of student specialization can be delayed significantly. We demonstrate that this phenomenon also occurs in various models of unsupervised learning. A

  7. A simulation of the SDC on-line processing farm

    International Nuclear Information System (INIS)

    Wang, C.; Chen, Y.; Dorenbosch, J.; Lee, J.; Sayle, R.

    1993-10-01

    In the Solenoidal Detector Collaboration (SDC) data acquisition system (DAQ), an enormous amount of data flows into a processor farm for extraction of interesting physics events. To design an efficient on-line filter, the operations in the farm must be carefully modeled. The authors present a simulation model developed at the Superconducting Super Collider Laboratory which efficiently allocates physics events to the farm

  8. An optimal algorithm for preemptive on-line scheduling

    NARCIS (Netherlands)

    Chen, B.; Vliet, van A.; Woeginger, G.J.

    1995-01-01

    We investigate the problem of on-line scheduling jobs on m identical parallel machines where preemption is allowed. The goal is to minimize the makespan. We derive an approximation algorithm with worst-case guarantee mm/(mm - (m - 1)m) for every m 2, which increasingly tends to e/(e - 1) ˜ 1.58 as m

  9. Comparison between constant methanol feed and on-line ...

    African Journals Online (AJOL)

    Two methanol feeding methods, namely constant methanol feed and on-line monitoring feed control by methanol sensor were investigated to improve the production of recombinant human growth hormone (rhGH) in high cell density cultivation of Pichia pastoris KM71 in 2 L bioreactor. The yeast utilized glycerol as a carbon ...

  10. Children's On-Line Processing of Scrambling in Japanese

    Science.gov (United States)

    Suzuki, Takaaki

    2013-01-01

    This study investigates the on-line processing of scrambled sentences in Japanese by preschool children and adults using a combination of self-paced listening and speeded picture selection tasks. The effects of a filler-gap dependency, reversibility, and case markers were examined. The results show that both children and adults had difficulty in…

  11. AAEC INIS - a large, new, on-line information source

    International Nuclear Information System (INIS)

    Rugg, T.J.; Wong, S.C.

    1984-01-01

    The Australian Atomic Energy Commission's INIS database is available for on-line searching by non-AAEC personnel from all parts of Australia. An introduction to the International Nuclear Information System is followed by information on searching AAEC INIS, AAEC INIS retrieval software and accessing AAEC INIS

  12. ORION-the Omega Remote Interactive On-line System

    CERN Document Server

    Russell, R D; Levratt, B; Lipps, H; Sparrman, P

    1974-01-01

    ORION is a system which permits the manipulation of files, records and characters, remote job submittal and retrieval of output files including the direct loading of remote on-line computers. The system uses the computer hardware of the OMEGA project at CERN and is designed to assist researchers in development and debugging of their programs. (10 refs).

  13. ORION - the OMEGA Remote Interactive On-line System

    CERN Document Server

    Russell, R D; Krieger, M

    1973-01-01

    ORION is a system which permits the manipulation of files, records and characters, remote job submittal and retrieval of output files including the direct loading of remote on-line computers. The system uses the computer hardware of the OMEGA project at CERN, and is designed to assist researchers in development and debugging of their programs.

  14. Booth Library On-Line Circulation System (BLOC

    Directory of Open Access Journals (Sweden)

    Paladugu V. Rao

    1971-06-01

    Full Text Available An on-line circulation system developed at a relatively small university library demonstrates that academic libraries with limited funds can develop automated systems utilizing parent institution's computer facilities in a time-sharing mode. In operation since September 1968, using an IBM 360/50 computer and associated peripheral equipment, it provides control over all stack books.

  15. On-line learning from clustered input examples

    NARCIS (Netherlands)

    Riegler, Peter; Biehl, Michael; Solla, Sara A.; Marangi, Carmela; Marinaro, Maria; Tagliaferri, Roberto

    1996-01-01

    We analyse on-line learning of a linearly separable rule with a simple perceptron. Example inputs are taken from two overlapping clusters of data and the rule is defined through a teacher vector which is in general not aligned with the connection line of the cluster centers. We find that the Hebb

  16. Investigating on-line pornography at the University of Johannesburg

    Directory of Open Access Journals (Sweden)

    P. Laughton

    2008-01-01

    Full Text Available The on-line user of today has access to a vast collection of information resources. In addition, the developments in Internet and Web technologies have made it even easier for surfers to anonymously get access to on-line pornography. The purpose of this research was to investigate the extent to which access to on-line pornography at the University of Johannesburg can be managed. For the empirical part of this research 1037 questionnaires were proportionally distributed to and completed by students on all five campuses of the university. The questionnaire consisted of four sections: biographical information; university computer facility usage; university acceptable use policy; and personal experience with university computer facilities. The gender distribution for the sample was almost even, with a total of 49,4% male participants and 50,6% female, with the largest grouping of respondents (61,6% aged between 19 years and 21 years. Of the respondents, 36,7% indicated that exposure to unsolicited pornography did not bother them. When asked to what extent students should have access to pornography, 60,5% stated 'None' while 32,6% believed that 'Restricted' access should be granted for research purposes and 6,9% believed that students should be granted 'Total' access to pornography. Results from the research will be used to manage access to on-line resources at the University of Johannesburg better.

  17. On-line sample treatment - Capillary gas chromatography

    NARCIS (Netherlands)

    Goosens, EC; de Jong, D; de Jong, GJ; Brinkman, UAT

    Sample pretreatment is often the bottleneck of a trace level analytical procedure. In order to increase performance, increasing attention is therefore being devoted to combining sample pretreatment on-line with the separation technique that has to be used. In the present review, a variety of

  18. A new electrostatic on-line collection-system

    International Nuclear Information System (INIS)

    Dufour, J.P.; Del Moral, R.; Fleury, A.

    1981-06-01

    The working conditions of a new on-line electrostatic collection system are presented. The main charactersitics are high efficiency (reaching 20%) and short delay time (down to the millisecond). The salient features of specific devices for measurements of absolute cross sections, recoil range distributions and angular distributions are given

  19. Summary remarks and prospects for on-line nuclear orientation

    International Nuclear Information System (INIS)

    Krane, K.S.; Hamilton, J.H.

    1984-01-01

    This paper reviews the use of on-line nuclear orientations as a method for determining hyperfine structure. Historical developments and future prospects for the technique are presented. The role that this technique can play in nuclear spectroscopy and the study of nuclei far from the beta stability are outlined

  20. WMI2, the Student's On-Line Symbolic Calculator

    Science.gov (United States)

    Kovacs, Zoltan

    2011-01-01

    Student activities focused on discovering mathematics play an important role in the teaching and learning process. WebMathematics Interactive (WMI2) was developed to offer a fast and user-friendly on-line web interface to enhance the quality of both theoretical and applied mathematics courses. For the teacher, in the classroom, it provides…

  1. ADAPTIVE CONTEXT PROCESSING IN ON-LINE HANDWRITTEN CHARACTER RECOGNITION

    NARCIS (Netherlands)

    Iwayama, N.; Ishigaki, K.

    2004-01-01

    We propose a new approach to context processing in on-line handwritten character recognition (OLCR). Based on the observation that writers often repeat the strings that they input, we take the approach of adaptive context processing. (ACP). In ACP, the strings input by a writer are automatically

  2. Microcomputers as on-line catalogs in special libraries.

    Science.gov (United States)

    Faust, J B

    1986-01-01

    This article discusses the rationale for the conversion of a card catalog to an on-line system in a special library owning approximately 4000 titles. Equipment, software, and procedures are described. Pros and cons of the use of a microcomputer for such a project, as well as costs and personnel needs, are outlined.

  3. Efficient and secure comparison for on-line auctions

    NARCIS (Netherlands)

    Damgard, Ivan; Geisler, M.; Kroigaard, M.; Pieprzyk, J.; Ghodosi, H.; Dawson, E.

    2007-01-01

    We propose a protocol for secure comparison of integers based on homomorphic encryption. We also propose a homomorphic encryption scheme that can be used in our protocol and makes it more efficient than previous solutions. Our protocol is well-suited for application in on-line auctions, both with

  4. The on-line asymmetric traveling salesman problem

    NARCIS (Netherlands)

    Ausiello, G.; Bonifaci, V.; Laura, L.

    2008-01-01

    We consider two on-line versions of the asymmetric traveling salesman problem with triangle inequality. For the homing version, in which the salesman is required to return in the city where it started from, we give a -competitive algorithm and prove that this is best possible. For the nomadic

  5. Facing regulatory challenges of on-line hemodiafiltration.

    Science.gov (United States)

    Kümmerle, Wolfgang

    2011-01-01

    On-line hemodiafiltration (on-line HDF) is the result of a vision that triggered multifarious changes in very different areas. Driven by the idea to offer better medical treatment for renal patients, technological innovations were developed and established that also constituted new challenges in the field of regulatory affairs. The existing regulations predominantly addressed the quality and safety of those products needed to perform dialysis treatment which were supplied by industrial manufacturers. However, the complexity of treatment system required for the provision of on-line fluids demanded a holistic approach encompassing all components involved. Hence, focus was placed not only on single products, but much more on their interfacing, and the clinical infrastructure, in particular, had to undergo substantial changes. The overall understanding of the interaction between such factors, quite different in their nature, was crucial to overcome the arising regulatory obstacles. This essay describes the evolution of the on-line HDF procedure from the regulatory point of view. A simplified diagram demonstrates the path taken from the former regulatory understanding to the realization of necessary changes. That achievement was only possible through 'management of preview' and consequent promotion of technical and medical innovations as well as regulatory re-evaluations. Copyright © 2011 S. Karger AG, Basel.

  6. Project development and commercialization of on-line analysis systems

    International Nuclear Information System (INIS)

    Watt, J.S.

    1997-01-01

    A project team first in the Australian Atomic Energy Commission (AAEC) and since 1982 in CSIRO has developed many on-line analysis systems for the mineral and energy industries. The development of these projects has followed a common pattern of laboratory R and D, field trials, commercialisation and technology transfer. This successful pattern is illustrated using examples of the development of systems for the on-line analysis of mineral slurries, for determination of the ash content of coal on conveyors, and for determination of the flow rates of oil, water and gas in pipelines. The first two systems are licensed to Australian companies, Amdel Ltd and Mineral Control Instrumentation Ltd. Both systems are used by industry worldwide, and are the market leaders for radioisotope gauges in their application field. The third system, the multiphase flow meter, was licensed in 1997 to Kvaerner FSSL Ltd of Aberdeen. This meter has even greater potential than the other two systems for economic benefit from its used and for numbers of installations. The on-line analysis systems have been developed to increase the productivity of the Australian mineral and energy industries, and to provide economic benefit to Australia. The economic benefit sought is predominantly improved process control based on use of the instrument, rather than from its sale. Sales of instruments are significant, however, with about A$80 million from the analysis systems and their derivatives since the 1970s. Some of the issues associated with the development of the on-line analysis system are outlined

  7. Position-specific isotope analysis by on-line pyrolysis coupled to IRMS

    Science.gov (United States)

    Gilbert, A.; Suda, K.; Yamada, K.; Ueno, Y.; Yoshida, N.

    2016-12-01

    Position-specific isotopic analyses (PSIA) provide unique information regarding the sources, sinks and processes related to natural molecules. For instance, PSIA of short-chain hydrocarbons could lead to temperature of formation and maturity of natural gas reservoirs [1][2]. In the last decade, quantitative Nuclear Magnetic Resonance (NMR) specrometry has been used for PSIA of organic molecules such as glucose or n-alkanes [3][4]. However, due to its low sensitivity, application to low amount geochemical samples remains challenging. In 1997, Corso & Brenna proposed to adapt a pyrolysis furnace to an isotope ratio mass spectrometer, making it possible the thermal degradation of the target molecule and the subsequent analysis of the d13C values of the fragments formed [5]. Starting from fatty acid methyl esters they demonstrated the absence of rearrangement during pyrolytic degradation and could determine the d13C value of carboxyl C-atom position. We adapted the system for the full characterization of position-specific isotope composition of small molecules (ethanol, acetic acid, alanine, propane). Nanomole amount of sample can be analyzed with a precision on intramolecular d13C values of 1‰ or lower [2]. We recently analyzed abiotic and thermogenic propane samples both from the field and from lab simulations. PSIA of propane shows systematic differences of position-specific isotope composition between thermogenic and abiotic samples. While the former show 13C-depletion on the terminal C-atom position - consistent with thermal cracking kinetic models [6] - abiotic samples show little or no preference for terminal or central 13C-isotopomer. These results emphasize the potential of PSIA to trace the the processes associated with organic molecules production. [1] Piasecki et al. 2016 GCA 188, 58 [2] Gilbert et al. 2016 GCA 177, 205 [3] Gilbert et al. 2012 PNAS, 109, 18204 [4] Gilbert et al. 2013 Org. Geochem, 62, 56 [5] Corso & Brenna 1997 PNAS, 94, 1049 [6] Tang et al., 2000 GCA 64, 2673

  8. IOOS Data Portals and Uniform On-line Browse Capabilities

    Science.gov (United States)

    Howard, M.; Currier, R. D.; Kobara, S.; Gayanilo, F.

    2015-12-01

    The Gulf of Mexico Coastal Ocean Observing System Regional Association (GCOOS-RA) is one of eleven Regional Associations organized under the NOAA-led U.S. Integrated Ocean Observing System (IOOS) Program Office. Each of the RAs operate standards-based regional data portals designed to aggregate near real-time and historical observed data and modeled outputs from distributed providers and to offer these and derived products in standardized ways to a diverse set of users. The RA's portals are based on the IOOS Data and Communications Plan which describes the functional elements needed for an interoperable system. One of these elements is called "Uniform On-line Browse" which is an informational service designed primarily to visualize the inventory of a portal. An on-line browse service supports the end user's need to discover what parameters are available, to learn the spatial and temporal extend of the holdings, and to examine the character of the data (e.g, variability, gappiness, etc). These pieces of information help the end user decide if the data are fit for his/her purpose and to construct valid data requests. Note that on-line browse is a distinctly different activity than data analysis because it seeks to yield knowledge about the inventory and not about what the data mean. "Uniform" on-line browse is a service that takes advantage of the standardization of the data portal's data access points. Most portals represent station locations on a map. This is a view of the data inventory but these plots are rarely generated by pulling data through the standards-based services offered to the end users but through methods only available to the portal programmers. This work will present results of Uniform On-line browse tools developed within GCOOS-RA and their applicability to other RA portals.

  9. Mentoring Narratives ON-LINE:Teaching the Principalship

    Directory of Open Access Journals (Sweden)

    Allison I. Griffith

    2002-05-01

    Full Text Available The need to develop new models for preparation of school administrators has been a prominent concern in educational discourse in the last decade. Having been criticized for the inadequate preparation of the school leadership cadre, academic departments responsible for training future school administrators have had to revisit their approaches and to reframe their teaching philosophies to ensure the readiness of their graduates for the challenges and complexities of school leadership. This article reports on the new model of principals' training that has been used in York University's Principals' Qualification Program (PQP from the late 1990s onward. One component of the program brings traditional case methodology into a computer-mediated/on-line environment. The on-line cases are narratives from the everyday lives of the Ontario school administrators who serve as mentors in the on-line environment. Situating our discussion within the context of the rapidly changing educational landscape of Ontario, we focus on the PQP model to explore experientially generated case narratives as one method for teaching and learning the work of the local school administrator. We focus particularly on the teaching and learning embedded in computer-mediated or on-line case narratives used in training teachers for school leadership. We argue that the complexities of school leadership—the social, cultural, relational, ethical and moral context of school leadership—can be taught effectively through the reflective processes of on-line case narratives. We seek to contribute to the ongoing dialogue on the potential of new pedagogies and new technologies to help prepare the competent and responsible leaders for tomorrow's schools.

  10. On-line analysis of water contamination by organic compounds; On-line-Analytik der Wasserverschmutzung durch organische Substanzen

    Energy Technology Data Exchange (ETDEWEB)

    Wagt, R. van der; Vos, F. de [Skalar Analytical (Netherlands); Babichenko, S.; Poryvkina, L. [Institute of Ecology, Tallinn (Estonia)

    1999-08-01

    In many environmental applications decomposing the mixture of substances in the water into its various chemical ingredients, for subsequent analysis, is a very complicated task. The most productive approach to on-line diagnosis is to treat the object as an integral spectroscopic sample, characterized by certain specific Spectral Fluorescent Signatures (SFS). The SFS are recorded as a matrix of fluorescent intensity of organic compounds in water, in co-ordinates of excitation and emission spectra, providing a three-dimensional spectrum. Spectral windows of SFS are defined by fluorescent characteristics of basic groups of organic substances in the water sample. The novel Skalar Fluo Imager, based on this principle, is intended for the analysis of organic compounds in natural, domestic, and technological waters in an on-line mode. (orig.) [German] In vielen Umweltschutzanwendungen stellt die Auftrennung eines Substanzgemisches zum Zweck der Analyse eine sehr komplizierte Aufgabe dar. Ein erfolgversprechender Ansatz fuer eine on-line-Diagnostik besteht darin, das Objekt als integrale Spektroskopieprobe zu betrachten, die durch bestimmte spezifische Spektral-Fluoreszenz-Signaturen (SFS) charakterisiert wird. Diese werden als Fluoreszenz-Intensitaets-Matrix organischer Verbindungen in Wasser dargestellt, mit Anregungs- und Emissionsspektren als weiteren Koordinaten, wodurch ein dreidimensionales Spektrum entsteht. Spektrale Fenster der SFS sind definiert als Fluoreszenzcharakteristika von Funktionsgruppen organischer Substanzen in der Wasserprobe. Der auf diesem Prinzip basierende Skalar Fluo Imager ist fuer die on-line-Analyse organischer Bestandteile in natuerlichen, Haus- und technischen Waessern gedacht. (orig.)

  11. Automatic Delineation of On-Line Head-And-Neck Computed Tomography Images: Toward On-Line Adaptive Radiotherapy

    International Nuclear Information System (INIS)

    Zhang Tiezhi; Chi Yuwei; Meldolesi, Elisa; Yan Di

    2007-01-01

    Purpose: To develop and validate a fully automatic region-of-interest (ROI) delineation method for on-line adaptive radiotherapy. Methods and Materials: On-line adaptive radiotherapy requires a robust and automatic image segmentation method to delineate ROIs in on-line volumetric images. We have implemented an atlas-based image segmentation method to automatically delineate ROIs of head-and-neck helical computed tomography images. A total of 32 daily computed tomography images from 7 head-and-neck patients were delineated using this automatic image segmentation method. Manually drawn contours on the daily images were used as references in the evaluation of automatically delineated ROIs. Two methods were used in quantitative validation: (1) the dice similarity coefficient index, which indicates the overlapping ratio between the manually and automatically delineated ROIs; and (2) the distance transformation, which yields the distances between the manually and automatically delineated ROI surfaces. Results: Automatic segmentation showed agreement with manual contouring. For most ROIs, the dice similarity coefficient indexes were approximately 0.8. Similarly, the distance transformation evaluation results showed that the distances between the manually and automatically delineated ROI surfaces were mostly within 3 mm. The distances between two surfaces had a mean of 1 mm and standard deviation of <2 mm in most ROIs. Conclusion: With atlas-based image segmentation, it is feasible to automatically delineate ROIs on the head-and-neck helical computed tomography images in on-line adaptive treatments

  12. On-line soft sensing in upstream bioprocessing.

    Science.gov (United States)

    Randek, Judit; Mandenius, Carl-Fredrik

    2018-02-01

    This review provides an overview and a critical discussion of novel possibilities of applying soft sensors for on-line monitoring and control of industrial bioprocesses. Focus is on bio-product formation in the upstream process but also the integration with other parts of the process is addressed. The term soft sensor is used for the combination of analytical hardware data (from sensors, analytical devices, instruments and actuators) with mathematical models that create new real-time information about the process. In particular, the review assesses these possibilities from an industrial perspective, including sensor performance, information value and production economy. The capabilities of existing analytical on-line techniques are scrutinized in view of their usefulness in soft sensor setups and in relation to typical needs in bioprocessing in general. The review concludes with specific recommendations for further development of soft sensors for the monitoring and control of upstream bioprocessing.

  13. On-line corrosion monitoring in district heating systems

    DEFF Research Database (Denmark)

    Richter, Sonja; Thorarinsdottir, R.I.; Hilbert, Lisbeth Rischel

    2004-01-01

    ), Electrochemical Noise (EN) and Zero Resistance Ammetry (ZRA). Electrochemical Resistance (ER) has also been used to measure corrosion. The method traditionally only measures corrosion off-line but with newly developed high-sensitive ER technique developed by MetriCorr in Denmark, on-line monitoring is possible...... complicates the chemistry of the environment. Hydrogen sulphide is present in geothermal systems and can be formed as a by-product of sulphate-reducing-bacteria (SRB). The application of electrochemical methods makes on-line monitoring possible. These methods include: Linear Polarization Resistance (LPR....... In order to assess both general corrosion and localized corrosion, it is necessary to apply more than one monitoring technique simultaneously, ZRA or EN for measuring localized corrosion and LPR or ER for measuring general corrosion rate. The advantage of monitoring localized corrosion is indisputable...

  14. On-line sources of toxicological information in Canada

    International Nuclear Information System (INIS)

    Racz, William J.; Ecobichon, Donald J.; Baril, Marc

    2003-01-01

    This paper will provide an overview of the on-line resources available in toxicology in Canada. It will describe a brief history of The Society of Toxicology of Canada, with reference to other societies and also provide information on education, research and other resources related to toxicology. Toxicology in Canada emerged as a distinct and vibrant discipline following the thalidomide tragedy of the 1960s. In the pharmaceutical industry and government, toxicology was readily established as an essential component of drug development and safety, and as the need for toxicologists expanded, training programs were established, usually in collaboration with departments of pharmacology. In the last two to three decades other disciplines, environmental biology, analytical chemistry and epidemiology joined the ranks of toxicology. The on-line sources of toxicology information are rapidly expanding. This article describes those sources considered by the authors to be important from a national and international perspective. The majority of these sources are professional organizations and government agencies

  15. On-line chemistry monitoring for the secondary side

    International Nuclear Information System (INIS)

    Anon.

    1990-01-01

    Babcock and Wilcox (B and W) has developed a computerized water chemistry data acquisition and management system for nuclear plant secondary coolant systems. The Integrated Water Chemistry Monitoring System (IWCMS) provides on-line monitoring of conditions and rapid trend analysis of sampled data. So far it has been installed at GPU Three Mile Island unit 1 and at Toledo Edison Davis-Besse. The IWCMS meets the following utility needs for monitoring power plant chemistry: control of chemistry conditions to minimize corrosion and extend component/system life; continuous analysis of data from on-line detectors and grab samples; expediting of transient recovery actions with trend, alarm and evaluation capability; provision for rapid sharing of useful operational chemistry information; concentration of attention on evaluation instead of data manipulation. The system is composed of three functional parts: data acquisition hardware; PC-based computer system and customised system software. (author)

  16. On-line application of the PANTHER advanced nodal code

    International Nuclear Information System (INIS)

    Hutt, P.K.; Knight, M.P.

    1992-01-01

    Over the last few years, Nuclear Electric has developed an integrated core performance code package for both light water reactors (LWRs) and advanced gas-cooled reactors (AGRs) that can perform a comprehensive range of calculations for fuel cycle design, safety analysis, and on-line operational support for such plants. The package consists of the following codes: WIMS for lattice physics, PANTHER whole reactor nodal flux and AGR thermal hydraulics, VIPRE for LWR thermal hydraulics, and ENIGMA for fuel performance. These codes are integrated within a UNIX-based interactive system called the Reactor Physics Workbench (RPW), which provides an interactive graphic user interface and quality assurance records/data management. The RPW can also control calculational sequences and data flows. The package has been designed to run both off-line and on-line accessing plant data through the RPW

  17. UniFlex - Collaborative on-line learning environment tool

    Directory of Open Access Journals (Sweden)

    Ole Borch

    2004-05-01

    Full Text Available

    Første gang publiceret i UNEV nr. 2: E-læringsplatforme - muligheder og potentialer, januar - marts 2004, red. Tom Nyvand og Michael Pedersen. ISSN 1603-5518.

    Increasing demands for remote on-line education are changing the way teaching and learning is performed. New behavior in using pedagogy and supporting technology is needed to drive the learning process. To facilitate the use of services for selected activities to participants in distance education, a web site named UniFlex (University Flexible learning has been developed and brought into use. The site is a comprehensive set of bookmarks including course taking, upload/download, and - of special significance - collaborative on-line project work. UniFlex has been developed to meet the requirement for a simple and cheap personalized interactive site, supporting problem oriented and project organized study form, which has characterized Aalborg University for more than 27 years.

  18. UniFlex - Collaborative on-line learning environment tool

    Directory of Open Access Journals (Sweden)

    Ole Borch

    2004-03-01

    Full Text Available Første gang publiceret i UNEV nr. 2: E-læringsplatforme - muligheder og potentialer, januar - marts 2004, red. Tom Nyvand og Michael Pedersen. ISSN 1603-5518. Increasing demands for remote on-line education are changing the way teaching and learning is performed. New behavior in using pedagogy and supporting technology is needed to drive the learning process. To facilitate the use of services for selected activities to participants in distance education, a web site named UniFlex (University Flexible learning has been developed and brought into use. The site is a comprehensive set of bookmarks including course taking, upload/download, and - of special significance - collaborative on-line project work. UniFlex has been developed to meet the requirement for a simple and cheap personalized interactive site, supporting problem oriented and project organized study form, which has characterized Aalborg University for more than 27 years.

  19. On-line analyzers to distributed control system linking

    Energy Technology Data Exchange (ETDEWEB)

    Peterson, S.F.; Buchanan, B.R.; Sanders, M.A.

    1990-01-01

    The Analytical Development Section (ADS) of the Savannah River Laboratory is developing on-line analyzers to monitor various site processes. Data from some of the on-line analyzers (OLA's) will be used for process control by distributed control systems (DCS's) such as the Fisher PRoVOX. A problem in the past has been an efficient and cost effective way to get analyzer data onto the DCS data highway. ADS is developing a system to accomplish the linking of OLA's to PRoVOX DCS's. The system will be described, and results of operation in a research and development environment given. Plans for the installation in the production environment will be discussed.

  20. On-line Ramsey Numbers for Paths and Stars

    Directory of Open Access Journals (Sweden)

    Jaroslaw Grytczuk

    2008-08-01

    Full Text Available We study on-line version of size-Ramsey numbers of graphs defined via a game played between Builder and Painter: in one round Builder joins two vertices by an edge and Painter paints it red or blue. The goal of Builder is to force Painter to create a monochromatic copy of a fixed graph H in as few rounds as possible. The minimum number of rounds (assuming both players play perfectly is the on-line Ramsey number r(H of the graph H. We determine exact values of r(H for a few short paths and obtain a general upper bound r(Pn ≤ 4n-7. We also study asymmetric version of this parameter when one of the target graphs is a star Sn with n edges. We prove that r(Sn,H≤n ·e(H when H is any tree, cycle or clique.

  1. Laser systems for on-line laser ion sources

    International Nuclear Information System (INIS)

    Geppert, Christopher

    2008-01-01

    Since its initiation in the middle of the 1980s, the resonant ionization laser ion source has been established as a reliable and efficient on-line ion source for radioactive ion beams. In comparison to other on-line ion sources it comprises the advantages of high versatility for the elements to be ionized and of high selectivity and purity for the ion beam generated by resonant laser radiation. Dye laser systems have been the predominant and pioneering working horses for laser ion source applications up to recently, but the development of all-solid-state titanium:sapphire laser systems has nowadays initiated a significant evolution within this field. In this paper an overview of the ongoing developments will be given, which have contributed to the establishment of a number of new laser ion source facilities worldwide during the last five years.

  2. On-Line Metrology with Conoscopic Holography: Beyond Triangulation

    Directory of Open Access Journals (Sweden)

    Ignacio Álvarez

    2009-09-01

    Full Text Available On-line non-contact surface inspection with high precision is still an open problem. Laser triangulation techniques are the most common solution for this kind of systems, but there exist fundamental limitations to their applicability when high precisions, long standoffs or large apertures are needed, and when there are difficult operating conditions. Other methods are, in general, not applicable in hostile environments or inadequate for on-line measurement. In this paper we review the latest research in Conoscopic Holography, an interferometric technique that has been applied successfully in this kind of applications, ranging from submicrometric roughness measurements, to long standoff sensors for surface defect detection in steel at high temperatures.

  3. The Bochum on-line data acquisition system

    International Nuclear Information System (INIS)

    Paul, H.J.; Freiesleben, H.

    1986-01-01

    We describe an on-line data acquisition system based on a PDP 11 computer with CAMAC hardware. The software fully exploits the real-time features of the RSX-11M operating system. The basic characteristics of the program package, mainly written in FORTRAN 77, are: multitasking, shared common blocks, dynamical access to CAMAC hardware and data, and command orientated user interface. The system is particularly tailored for data acquisition in list mode of up to 64 parameters. (orig.)

  4. Recovery Strategies in On-Line Service Failure

    OpenAIRE

    Ozuem, Wilson; Lancaster, Geoff

    2013-01-01

    Despite a proliferation of a number of studies on service failures and recovery in e-service settings, there is a paucity of knowledge of ways in which service failures and recovery practices are implemented in the fashion industry. Drawing on constructivist perspective, this study offers a new perspective on an effective relational mechanism that would bridge the rupture between consumers and companies particularly in the on-line fashion sector. The analysis adds to studies on service failur...

  5. Understanding Cognitive Load Using On-line Dictionaries

    OpenAIRE

    Robert F. , Dilenschneider

    2017-01-01

    Cognitive Load Theory may useful for language instructors to understand how the look up conditions ofusing an on-line dictionary might influence learning. This paper first reviews previous studies that haveinvestigated dictionary use for vocabulary acquisition and reading comprehension Second, it explainsthe various elements of Cognitive Load Theory. Third, it describes how Cognitive Load Theory appliesto language learners' to learn unknown words and comprehend texts Last, it discusses the pe...

  6. On-line diagnostics for a real time system

    International Nuclear Information System (INIS)

    Sreenivasan, P.

    1976-01-01

    The purpose of an on-line diagnostics is to infuse the ability of self diagnosing in an online computer to enhance its dependability in a real time system. Such a diagnostics evolved for the CDPS of the Fast Breeder Test Reactor at Kalpakkam is reported. The two phases of the diagnostics, i.e., the malfunction detection and post detection action are described in some detail. (A.K.)

  7. Isocele I, the Orsay synchrocyclotron on-line separator

    International Nuclear Information System (INIS)

    Caruette, A.; Ferro, A.; Foucher, R.

    1976-01-01

    The main characteristics of the isotope separator Isocele 1 are described. This medium current separator was on line with the Orsay synchrocyclotron (155 MeV p, or 210 MeV 3 He) from March 1974 up to May 1975. Results obtained with different targets (Au, Bi, Er, Pt, Sn, Th) are summarized. They confirm the efficiency of medium current separators of this type [fr

  8. A decision support system for on-line leakage localization

    OpenAIRE

    Meseguer, Jordi; Mirats-Tur, Josep M.; Cembrano, Gabriela; Puig, Vicenç; Quevedo, Joseba; Pérez, Ramon; Sanz, Gerard; Ibarra, David

    2014-01-01

    This paper describes a model-driven decision-support system (software tool) implementing a model-based methodology for on-line leakage detection and localization which is useful for a large class of water distribution networks. Since these methods present a certain degree of complexity which limits their use to experts, the proposed software tool focuses on the integration of a method emphasizing its use by water network managers as a decision support system. The proposed software tool integr...

  9. On-line learning in radial basis functions networks

    OpenAIRE

    Freeman, Jason; Saad, David

    1997-01-01

    An analytic investigation of the average case learning and generalization properties of Radial Basis Function Networks (RBFs) is presented, utilising on-line gradient descent as the learning rule. The analytic method employed allows both the calculation of generalization error and the examination of the internal dynamics of the network. The generalization error and internal dynamics are then used to examine the role of the learning rate and the specialization of the hidden units, which gives ...

  10. On-line production of [11C]cyanogen bromide

    International Nuclear Information System (INIS)

    Westerberg, G.; Laangstroem, B.

    1997-01-01

    The electrophilic labelling precursor [ 11 C]cyanogen bromide was produced in 95% radiochemical yield (decay-corrected) from hydrogen [ 11 C]cyanide within 3 min from the end of bombardment using a simple and convenient solid-phase on-line procedure. The [ 11 C]cyanogen bromide has been used in the synthesis of a number of labelled compounds for use in positron emission tomography. (author)

  11. On-line Monitoring System for Power Transformers

    Directory of Open Access Journals (Sweden)

    Alexandru HOTEA

    2016-12-01

    Full Text Available Power transformers are the most important and expensive equipment from the electricity transmission system, so it is very important to know the real state of health of such equipment in every moment. De-energizing the power transformer accidentally due to internal defects can generate high costs. Annual maintenance proved to be ineffective in many cases to determine the internal condition of the equipment degradation due to faults rapidly evolving. An On-line Monitoring System for Power Transformers help real-time condition assessment and to detect errors early enough to take action to eliminate or minimize them. After abnormality detected, it is still important to perform full diagnostic tests to determine the exact condition of the equipment. On-line monitoring systems can help increase the level of availability and reliability of power transformers and lower costs of accidental interruption. This paper presents cases studies on several power transformers equipped with on-line monitoring systems from Transelectrica substation.

  12. Characterizing chemical systems with on-line computers and graphics

    International Nuclear Information System (INIS)

    Frazer, J.W.; Rigdon, L.P.; Brand, H.R.; Pomernacki, C.L.

    1979-01-01

    Incorporating computers and graphics on-line to chemical experiments and processes opens up new opportunities for the study and control of complex systems. Systems having many variables can be characterized even when the variable interactions are nonlinear, and the system cannot a priori be represented by numerical methods and models. That is, large sets of accurate data can be rapidly acquired, then modeling and graphic techniques can be used to obtain partial interpretation plus design of further experimentation. The experimenter can thus comparatively quickly iterate between experimentation and modeling to obtain a final solution. We have designed and characterized a versatile computer-controlled apparatus for chemical research, which incorporates on-line instrumentation and graphics. It can be used to determine the mechanism of enzyme-induced reactions or to optimize analytical methods. The apparatus can also be operated as a pilot plant to design control strategies. On-line graphics were used to display conventional plots used by biochemists and three-dimensional response-surface plots

  13. On-Line Fringe Tracking and Prediction at IOTA

    Science.gov (United States)

    Wilson, Edward; Mah, Robert; Lau, Sonie (Technical Monitor)

    1999-01-01

    The Infrared/Optical Telescope Array (IOTA) is a multi-aperture Michelson interferometer located on Mt. Hopkins near Tucson, Arizona. To enable viewing of fainter targets, an on-line fringe tracking system is presently under development at NASA Ames Research Center. The system has been developed off-line using actual data from IOTA, and is presently undergoing on-line implementation at IOTA. The system has two parts: (1) a fringe tracking system that identifies the center of a fringe packet by fitting a parametric model to the data; and (2) a fringe packet motion prediction system that uses characteristics of past fringe packets to predict fringe packet motion. Combined, this information will be used to optimize on-line the scanning trajectory, resulting in improved visibility of faint targets. Fringe packet identification is highly accurate and robust (99% of the 4000 fringe packets were identified correctly, the remaining 1% were either out of the scan range or too noisy to be seen) and is performed in 30-90 milliseconds on a Pentium II-based computer. Fringe packet prediction, currently performed using an adaptive linear predictor, delivers a 10% improvement over the baseline of predicting no motion.

  14. Review of trigger and on-line processors at SLAC

    International Nuclear Information System (INIS)

    Lankford, A.J.

    1984-07-01

    The role of trigger and on-line processors in reducing data rates to manageable proportions in e + e - physics experiments is defined not by high physics or background rates, but by the large event sizes of the general-purpose detectors employed. The rate of e + e - annihilation is low, and backgrounds are not high; yet the number of physics processes which can be studied is vast and varied. This paper begins by briefly describing the role of trigger processors in the e + e - context. The usual flow of the trigger decision process is illustrated with selected examples of SLAC trigger processing. The features are mentioned of triggering at the SLC and the trigger processing plans of the two SLC detectors: The Mark II and the SLD. The most common on-line processors at SLAC, the BADC, the SLAC Scanner Processor, the SLAC FASTBUS Controller, and the VAX CAMAC Channel, are discussed. Uses of the 168/E, 3081/E, and FASTBUS VAX processors are mentioned. The manner in which these processors are interfaced and the function they serve on line is described. Finally, the accelerator control system for the SLC is outlined. This paper is a survey in nature, and hence, relies heavily upon references to previous publications for detailed description of work mentioned here. 27 references, 9 figures, 1 table

  15. On-line plant-wide monitoring using neural networks

    International Nuclear Information System (INIS)

    Turkcan, E.; Ciftcioglu, O.; Eryurek, E.; Upadhyaya, B.R.

    1992-06-01

    The on-line signal analysis system designed for a multi-level mode operation using neural networks is described. The system is capable of monitoring the plant states by tracking different number of signals up to 32 simultaneously. The data used for this study were acquired from the Borssele Nuclear Power Plant (PWR type), and using the on-line monitoring system. An on-line plant-wide monitoring study using a multilayer neural network model is discussed in this paper. The back-propagation neural network algorithm is used for training the network. The technique assumes that each physical state of the power plant can be represented by a unique pattern of instrument readings which can be related to the condition of the plant. When disturbance occurs, the sensor readings undergo a transient, and form a different set of patterns which represent the new operational status. Diagnosing these patterns can be helpful in identifying this new state of the power plant. To this end, plant-wide monitoring with neutral networks is one of the new techniques in real-time applications. (author). 9 refs.; 5 figs

  16. Designing effective on-line continuing medical education.

    Science.gov (United States)

    Zimitat, Craig

    2001-03-01

    The Internet, and new information and communication technologies available through the Internet, provides medical educators with an opportunity to develop unique on-line learning environments with real potential to improve physicians' knowledge and effect change in their clinical practice. There are approximately 100 websites offering on-line CME courses in the USA alone. However, few of these CME courses appear to be based on sound educational principles or CME research and may have little chance of achieving the broader goals of CME. The majority of these courses closely resemble their traditional counterparts (e.g. paper-based books are now electronic books) and appear to be mere substitutions for old-technology CME resources. Whilst some CME providers add unique features of the Internet to enrich their websites, they do not employ strategies to optimize the learning opportunities afforded by this new technology. The adoption of adult learning principles, reflective practice and problem-based approaches can be used as a foundation for sound CME course design. In addition, knowledge of Internet technology and the learning opportunities it affords, together with strategies to maintain participation and new assessment paradigms, are all needed for developing online CME. We argue for an evidence-based and strategic approach to the development of on-line CME courses designed to enhance physician learning and facilitate change in clinical behaviour.

  17. On-line radiation teaching materials using IT technology

    International Nuclear Information System (INIS)

    Inoue, Hiroyoshi

    2005-01-01

    We developed the on-line radiation teaching materials using the Internet, in order to provide the teaching support materials of atomic power and radiation educations in on-school study, as well as to create the complementary study system in off-school study. The themes of teaching materials were selected from requests by teachers. In the case of an elementary school, the teaching material 'an environmental problem and atomic power' was created as the aggregate of each content for study without boundary between subjects. The teaching material 'medical treatment and radiation' was created for junior high school students to raise the individual knowledge. In the case of a high school, the teaching material nucleus and radiation' was prepared to supplement the physical study of students. The on-line teaching materials were tried to 300 junior high school and high school students, 68% of students answered that the teaching material is effective to understand atomic power and radiation, though 17% answered they were not effective. Although there are problems to prepare IT learning equipments and learning follow-up system in the material, it is suggested that the on-line teaching materials will provide the novel learning system including debates for the study. This method has no limitation of time and place. (author)

  18. On-line fouling monitor for heat exchangers

    International Nuclear Information System (INIS)

    Tsou, J.L.

    1995-01-01

    Biological and/or chemical fouling in utility service water system heat exchangers adversely affects operation and maintenance costs, and reduced heat transfer capability can force a power deaerating or even a plant shut down. In addition, service water heat exchanger performance is a safety issue for nuclear power plants, and the issue was highlighted by NRC in Generic Letter 89-13. Heat transfer losses due to fouling are difficult to measure and, usually, quantitative assessment of the impact of fouling is impossible. Plant operators typically measure inlet and outlet water temperatures and flow rates and then perform complex calculations for heat exchanger fouling resistance or ''cleanliness''. These direct estimates are often imprecise due to inadequate instrumentation. Electric Power Research Institute developed and patented an on-line condenser fouling monitor. This monitor may be installed in any location within the condenser; does not interfere with routine plant operations, including on-line mechanical and chemical treatment methods; and provides continuous, real-time readings of the heat transfer efficiency of the instrumented tube. This instrument can be modified to perform on-line monitoring of service water heat exchangers. This paper discusses the design, construction of the new monitor, and algorithm used to calculate service water heat exchanger fouling

  19. Denmark's on - line early warning radiation monitoring network

    International Nuclear Information System (INIS)

    Walmod-Larsen, O.; Lippert, J.

    1990-01-01

    In Denmark an emergency response coordination committee was set up to cope with the problems after the Chernobyl accident with participation of all relevant authorities. For help in an emergency situation the ARGOS (Accident Reporting and Guiding Operational System), system will be put into use. The ARGOS emergency evaluation computer system, which has been developed in cooperation with the Danish Environmental Protection Agency, is in operation in connection with the emergency planning for the east region of Denmark with regard to the Swedish nuclear power plant operating at Barseback. Inputs of measurement data are on-line available on data screens for evaluation in the emergency coordination centers, presented on suitable geographical maps, showing iso-contours calculated from the input. In case of an alert situation other systems can be put in operation, f.ex. mobile measuring units from the CDEPA's local, operational emergency centers. Their readings can then be put into the computing system parallel to the on-line stations and be presented by the ARGOS-system for evaluation in the emergency command centers. If another national authority in an alert situation requests a transfer of measurement data, and if this is agreed upon by the competent Danish authority, then the transfer can be arranged from the ARGOS-system, through agreed transmission channels. At present the ARGOS system is being improved and expanded by RNL to cover the whole Danish region and to present measurements from the on-line warning system

  20. In the Jungle of Astronomical On--line Data Services

    Science.gov (United States)

    Egret, D.

    The author tried to survive in the jungle of astronomical on--line data services. In order to find efficient answers to common scientific data retrieval requests, he had to collect many pieces of information, in order to formulate typical user scenarios, and try them against a number of different data bases, catalogue services, or information systems. He discovered soon how frustrating treasure coffers may be when their keys are not available, but he realized also that nice widgets and gadgets are of no help when the information is not there. And, before long, he knew he would have to navigate through several systems because no one was yet offering a general answer to all his questions. I will present examples of common user scenarios and show how they were tested against a number of services. I will propose some elements of classification which should help the end-user to evaluate how adequate the different services may be for providing satisfying answers to specific queries. For that, many aspects of the user interaction will be considered: documentation, access, query formulation, functionalities, qualification of the data, overall efficiency, etc. I will also suggest possible improvements to the present situation: the first of them being to encourage system managers to increase collaboration between one another, for the benefit of the whole astronomical community. The subjective review I will present, is based on publicly available astronomical on--line services from the U.S. and from Europe, most of which (excepting the newcomers) were described in ``Databases and On-Line Data in Astronomy", (Albrecht & Egret, eds, 1991): this includes databases (such as NED and Simbad ), catalog services ( StarCat , DIRA , XCatScan , etc.), and information systems ( ADS and ESIS ).

  1. On-line implant reconstruction in HDR brachytherapy

    International Nuclear Information System (INIS)

    Kolkman-Deurloo, Inger-Karine K.; Kruijf, Wilhelmus J.M. de; Levendag, Peter C.

    2006-01-01

    Background and purpose: To evaluate the accuracy of on-line planning in an Integrated Brachytherapy Unit (IBU) using dedicated image distortion correction algorithms, correcting the geometric distortion and magnetic distortion separately, and to determine the effect of the reconstruction accuracy on clinical treatment plans in terms of deviations in treatment time and dose. Patients and methods: The reconstruction accuracy has been measured using 20 markers, positioned at well known locations in a QA phantom. Treatment plans of two phantoms representing clinical implant geometries, have been compared with reference plans to determine the effect of the reconstruction accuracy on the treatment plan. Before clinical introduction, treatment plans of three representative patients, based on on-line reconstruction, have been compared with reference plans. Results: The average reconstruction error for 10 in. images reduces from -0.6 mm (range -2.6 to +1.0 mm) to -0.2 mm (range -1.2 to +0.6 mm) after image distortion correction and for 15 in. images from 0.8 mm (range -0.5 to +3.0 mm) to 0.0 mm (range -0.8 to +0.8 mm). The error in case of eccentric positioning of the phantom, i.e. 0.8 mm (range -1.0 to +3.3 mm), reduces to 0.1 mm (range -0.5 to +0.9 mm). Correction of the image distortions reduces the deviation in the calculated treatment time of maximally 2.7% to less than 0.8% in case of eccentrically positioned clinical phantoms. The deviation in the treatment time or reference dose in the plans based on on-line reconstruction with image distortion correction of the three patient examples is smaller than 0.3%. Conclusions: Accurate on-line implant reconstruction using the IBU localiser and dedicated correction algorithms separating the geometric distortion and the magnetic distortion is possible. The results fulfill the minimum requirements as imposed by the Netherlands Commission on Radiation Dosimetry (NCS) without limitations regarding the usable range of the field

  2. On-line data processing for scintillation camera

    International Nuclear Information System (INIS)

    Ueyanagi, Hideo

    1974-01-01

    To process on-line the information from scintillation cameras, the computing/processing device of wired program type, with a specialized mini-computer for the processing, is generally used; and by this method, the data processing is done by the users of scintillation cameras. In the device with a mini-computer with processing programming by software, the almost all items in processing can be executed; but the operation requires some skill. With mini-computer operation, on the other hand, there are the problems of data-point number, process-time reduction, and image storage for both long and short terms. (Mori, K.)

  3. Robust Control Methods for On-Line Statistical Learning

    Directory of Open Access Journals (Sweden)

    Capobianco Enrico

    2001-01-01

    Full Text Available The issue of controlling that data processing in an experiment results not affected by the presence of outliers is relevant for statistical control and learning studies. Learning schemes should thus be tested for their capacity of handling outliers in the observed training set so to achieve reliable estimates with respect to the crucial bias and variance aspects. We describe possible ways of endowing neural networks with statistically robust properties by defining feasible error criteria. It is convenient to cast neural nets in state space representations and apply both Kalman filter and stochastic approximation procedures in order to suggest statistically robustified solutions for on-line learning.

  4. Development of an on-line radon monitoring system

    International Nuclear Information System (INIS)

    Guo Huiping; Shang Aiguo; Liu Junfeng; Zhou Chunlin; Di Yuming

    2004-01-01

    Of the actual demand by the strategic missile troops, the author has successfully developed a specially designed passive diffusion collecting chamber to collect the decay products of radon by high voltage static electricity, and using the single-chip microcomputer to reckon the radon concentration in air, which is actually a portable, continuous and automatic on-line monitoring instrument. It was made into a four-slot standard plug-in board of a NIM, and it functions as auto data memory, data process, display, over-threshold alarming and so on. (authors)

  5. On-line Dynamic Security Assessment in Power Systems

    DEFF Research Database (Denmark)

    Weckesser, Johannes Tilman Gabriel

    and solar radiation. Moreover, ongoing research suggests that demand response will be introduced to maintain power balance between generation and consumption at all times. Due to these changes the operating point of the power system will be less predictable and today’s stability and security assessment...... for early prediction of critical voltage sags is described. The method’s performance is compared to other prediction approaches. The results show that the proposed method succeeds in early, accurately and consistently predicting critically low voltage sags. An efficient on-line DSA not only identifies...

  6. Enhancing Learner Autonomy in an On-line Editing Programme

    Directory of Open Access Journals (Sweden)

    Hebe Wong

    2011-09-01

    Full Text Available Little (1999 argues that in formal educational contexts, “the basis of learner autonomy is acceptance of responsibility for one’s own learning” (p.11. An autonomous learner takes responsibility for various aspects of learning (Benson & Voller, 1997; Holec, 1981. This study examines how learner autonomy opportunities were provided at various stages of writing in an on-line editing programme for a group of electronic engineering students and how the students took charge of their language learning when receiving feedback on their technical writing. The impact on their own learning effectiveness of the decisions students made is also discussed.

  7. Investigating on-line pornography at the University of Johannesburg

    Directory of Open Access Journals (Sweden)

    P. Laughton

    2007-12-01

    (61,6% aged between 19 years and 21 years. Of the respondents, 36,7% indicated that exposure to unsolicited pornography did not bother them. When asked to what extent students should have access to pornography, 60,5% stated 'None' while 32,6% believed that 'Restricted' access should be granted for research purposes and 6,9% believed that students should be granted 'Total' access to pornography. Results from the research will be used to manage access to on-line resources at the University of Johannesburg better.

  8. On-line core monitoring with CORE MASTER / PRESTO

    International Nuclear Information System (INIS)

    Lindahl, S.O.; Borresen, S.; Ovrum, S.

    1986-01-01

    Advanced calculational tools are instrumental in improving reactor plant capacity factors and fuel utilization. The computer code package CORE MASTER is an integrated system designed to achieve this objective. The system covers all main activities in the area of in-core fuel management for boiling water reactors; design, operation support, and on-line core monitoring. CORE MASTER operates on a common data base, which defines the reactor and documents the operating history of the core and of all fuel bundles ever used

  9. Core on-line monitoring and computerized procedures systems

    International Nuclear Information System (INIS)

    Gangloff, W.C.

    1986-01-01

    The availability of operating nuclear power plants has been affected significantly by the difficulty people have in coping with the complexity of the plants and the operating procedures. Two ways to use modern computer technology to ease the burden of coping are discussed in this paper, an on-line core monitoring system with predictive capability and a computerized procedures system using live plant data. These systems reduce human errors by presenting information rather than simply data, using the computer to manipulate the data, but leaving the decisions to the plant operator

  10. Lower Bounds and Semi On-line Multiprocessor Scheduling

    Directory of Open Access Journals (Sweden)

    T.C. Edwin Cheng

    2003-10-01

    Full Text Available We are given a set of identical machines and a sequence of jobs from which we know the sum of the job weights in advance. The jobs have to be assigned on-line to one of the machines and the objective is to minimize the makespan. An algorithm with performance ratio 1.6 and a lower bound of 1.5 is presented. This improves recent results by Azar and Regev who published an algorithm with performance ratio 1.625 for the less general problem that the optimal makespan is known in advance.

  11. Adaptive calibration method with on-line growing complexity

    Directory of Open Access Journals (Sweden)

    Šika Z.

    2011-12-01

    Full Text Available This paper describes a modified variant of a kinematical calibration algorithm. In the beginning, a brief review of the calibration algorithm and its simple modification are described. As the described calibration modification uses some ideas used by the Lolimot algorithm, the algorithm is described and explained. Main topic of this paper is a description of a synthesis of the Lolimot-based calibration that leads to an adaptive algorithm with an on-line growing complexity. The paper contains a comparison of simple examples results and a discussion. A note about future research topics is also included.

  12. The development of an on-line gold analyser

    International Nuclear Information System (INIS)

    Robert, R.V.D.; Ormrod, G.T.W.

    1982-01-01

    An on-line analyser to monitor the gold in solutions from the carbon-in-pulp process is described. The automatic system is based on the delivery of filtered samples of the solutions to a distribution valve for measurement by flameless atomic-absorption spectrophotometry. The samples is introduced by the aerosol-deposition method. Operation of the analyser on a pilot plant and on a full-scale carbon-in-pulp plant has shown that the system is economically feasible and capable of providing a continuous indication of the efficiency of the extraction process

  13. NNDC [National Nuclear Data Center] on-line services documentation

    International Nuclear Information System (INIS)

    Dunford, C.L.; Burrows, T.W.; Tuli, J.K.

    1987-01-01

    This document summarizes and describes how to access the on-line services available from the National Nuclear Data Center (NNDC) located at Brookhaven National Laboratory. The services are available free of cost to US Department of Energy, its contractors and others who support the NNDC or supply data to the NNDC. Four of the center's data bases are now accessible to non-NNDC scientists via remote connection to the center's VAX 11/780. To use this service, you must have a terminal with access by either a telephone line or the PHYSNET network. A VT100 terminal or a terminal with VT-100 emulation is recommended but not required

  14. Efficient and Secure Comparison for On-Line Auctions

    DEFF Research Database (Denmark)

    Damgård, Ivan Bjerre; Krøigaard, Mikkel; Geisler, Martin Joakim

    2007-01-01

    We propose a protocol for secure comparison of integers based on homomorphic encryption. We also propose a homomorphic encryption scheme that can be used in our protocol and makes it more efficient than previous solutions. Our protocol is well-suited for application in on-line auctions, both...... with respect to functionality and performance. It minimizes the amount of information bidders need to send, and for comparison of 16 bit numbers with security based on 1024 bit RSA (executed by two parties), our implementation takes 0.28 seconds including all computation and communication. Using precomputation...

  15. On-line computing in a classified environment

    International Nuclear Information System (INIS)

    O'Callaghan, P.B.

    1982-01-01

    Westinghouse Hanford Company (WHC) recently developed a Department of Energy (DOE) approved real-time, on-line computer system to control nuclear material. The system simultaneously processes both classified and unclassified information. Implementation of this system required application of many security techniques. The system has a secure, but user friendly interface. Many software applications protect the integrity of the data base from malevolent or accidental errors. Programming practices ensure the integrity of the computer system software. The audit trail and the reports generation capability record user actions and status of the nuclear material inventory

  16. On-line fatigue monitoring and margins probabilistic assessment

    International Nuclear Information System (INIS)

    Fournier, I.; Morilhat, P.

    1993-01-01

    An on-line computer aided system has been developed by Electricite de France, the French utility, for a fatigue monitoring of critical locations in the nuclear steam supply system. This tool, called fatiguemeter, includes as input data only existing plant parameters and is based on some conservative assumptions at several steps of the damage assessment (thermal boundary conditions, stress computation...). This paper presents recent developments performed toward a better assessing of margins involved in the complete analysis. The methodology is enlightened with an example showing the influence of plant parameters incertitude on the final stress computed at a PWR 900 MW unit pressurizer surge line nozzle. (author)

  17. On-line system for investigation of atomic structure

    International Nuclear Information System (INIS)

    Amus'ya, M.Ya.; Chernysheva, L.V.

    1983-01-01

    A description of the on-line ATOM system is presented that enables to investigate the structure of atomic electron shells and their interactions with different scattering particles-electrons, positronse photons, mesons - with the use of computerized numerical solutions. The problem is stated along with mathematical description of atomic properties including theoretical and numerical models for each investigated physical process. The ATOM system structure is considered. The Hartree-Fock method is used to determine the wave functions of the ground and excited atomic states. The programs are written in the ALGOL langauge. Different atomic characteristics were possible to be calculated for the first time with an accuracy exceeding an experimental one

  18. ELT-MELAS analyzer and its on-line programs

    International Nuclear Information System (INIS)

    Anikeev, V.B.; Berezhnoj, V.A.; Glupova

    1976-01-01

    ELT-MELAS device constructed for an automatic analysis of pictures from big bubble chambers is described. It is controlled by a medium-size ICL-1903A computer and has two measuring modes: analysis of the ''agreement'' signal and digitation of slice-scans. Main features of the hardware and of on-line controlling and diagnostic software are presented. The test results of the MELAS complex as well as preliminary results of the scan-slice measurements of pictures from 15sup(') chamber are given

  19. Expanded beam spectro-ellipsometry for big area on-line monitoring

    Science.gov (United States)

    Fried, M.; Major, C.; Juhasz, G.; Petrik, P.; Horvath, Z.

    2015-05-01

    Non-destructive analysing tools are needed at all stages of thin film process-development, especially photovoltaic (PV) development, and on production lines. In the case of thin films, layer thicknesses, micro-structure, composition, layer optical properties, and their uniformity are important parameters. An important focus is to express the dielectric functions of each component material in terms of a handful of wavelength independent parameters whose variation can cover all process variants of that material. With the resulting database, spectroscopic ellipsometry coupled with multilayer analysis can be developed for on-line point-by-point mapping and on-line line-by-line imaging. Off-line point-by-point mapping can be effective for characterization of non-uniformities in full scale PV panels or big area (even 450 mm diameter) Si-wafers in developing labs but it is slow in the on-line mode when only 15 points can be obtained (within 1 min) as a 120 cm long panel moves by the mapping station. Last years [M. Fried et al, Thin Solid Films 519, 2730 (2011)], a new instrumentation was developed that provides a line image of spectroscopic ellipsometry (wl=350- 1000 nm) data. Earlier a single 30 point line image could be collected in 10 s over a 15 cm width of PV material. Recent years we have built a 30, a 45 and a 60 cm width expanded beam ellipsometer which speed is increased by 10x. Now, 1800 points can be mapped in a 1 min traverse of a 60*120 cm PV panel or flexible roll-to-roll substrate.

  20. Development of on-line core performance evaluation system for 'FUGEN'

    International Nuclear Information System (INIS)

    Natori, Hisahide; Kaneto, Kunikazu; Oteru, Shigeru.

    1982-01-01

    An on-line core performance evaluation system ATROPOS has been developed in order to carry out safe and efficient reactor operation of ''FUGEN''(a heavy water moderated, boiling light water cooled, pressure tube type reactor). This system offers detailed and useful information on such items of core performance as core thermal power, power distribution and thermal operation limits. The power distribution is calculated first by using a three-dimensional nodal coupling model, employing such process data as control rod position and 10 B concentration in the D 2 O moderator. Then the calculated power distribution is corrected by local power monitor readings. An axial one-dimensional nodal coupling model, which considers radial power distribution, and a localized three-dimensional nodal coupling model are used to predict the core thermal power and the power distribution for the region surrounding the control rods respectively, within a short time in advance of control rod operation. The methods employed in this system are verified by comparison with start-up test data from the FUGEN initial core. The estimated power distribution and channel flow agree with values measured by the power calibration monitor and with channel flow converted from measured values of pressure drop, within 3 and 5% respectively, in their root mean square values. The difference in core thermal power between the predicted value and the value measured by the total power monitor is about 1% for control rod operation. (author)

  1. TARMS, an on-line boiling water reactor operation management system

    International Nuclear Information System (INIS)

    Iwamoto, T.; Sakurai, S.; Uematsu, H.; Tsuiki, M.; Makino, K.

    1984-01-01

    The TARMS (Toshiba Advanced Reactor Management System) software package was developed as an effective on-line, on-site tool for boiling water reactor core operation management. It was designed to support a complete function set to meet the requirement to the current on-line process computers. The functions can be divided into two categories. One is monitoring of the present core power distribution as well as related limiting parameters. The other is aiding site engineers or reactor operators in making the future reactor operating plan. TARMS performs these functions with a three-dimensional BWR core physics simulator LOGOS 2, which is based on modified one-group, coarse-mesh nodal diffusion theory. A method was developed to obtain highly accurate nodal powers by coupling LOGOS 2 calculations with the readings of an in-core neutron flux monitor. A sort of automated machine-learning method also was developed to minimize the errors caused by insufficiency of the physics model adopted in LOGOS 2. In addition to these fundamental calculational methods, a number of core operation planning aid packages were developed and installed in TARMS, which were designed to make the operator's inputs simple and easy. (orig.) [de

  2. On line surveillance of large systems: applications to nuclear and chemical plant

    International Nuclear Information System (INIS)

    Zwingelstein, G.

    1978-01-01

    An on line surveillance method for large scale and distributed parameter systems is achieved by comparing in real time the internal physical parameter values to the reference values. It is shown that the following steps are necessary: modeling, model validation using dynamic testing and on line estimation of parameters. For large scale systems where only few outputs are measurable, an estimation algorithm was developed, selecting the measurable output giving the minimum variance of the physical parameters. This estimation scheme uses a quasilinearization technique associated to the sensitivity equation and the recursive least squares techniques. For large scale systems of order greater than 100, two versions of the estimation scheme are proposed to decrease the computation time. An application to a nuclear reactor core (state variable model of order 29) is proposed and used real data. For distributed systems the estimation scheme was developed with either measurements at fixed time or at fixed space. The estimation algorithm selects the set of measurements that gives the minimum variance of the estimates. An application to a liquid-liquid extraction column, modelized by a set of four coupled partial differential equations, demonstrates the efficiency of the method

  3. Human comment dynamics in on-line social systems

    Science.gov (United States)

    Wu, Ye; Zhou, Changsong; Chen, Maoying; Xiao, Jinghua; Kurths, Jürgen

    2010-12-01

    Human comment is studied using data from ‘tianya’ which is one of the most popular on-line social systems in China. We found that the time interval between two consecutive comments on the same topic, called inter-event time, follows a power-law distribution. This result shows that there is no characteristic decay time on a topic. It allows for very long periods without comments that separate bursts of intensive comments. Furthermore, the frequency of a different ID commenting on a topic also follows a power-law distribution. It indicates that there are some “hubs” in the topic who lead the direction of the public opinion. Based on the personal comments habit, a model is introduced to explain these phenomena. The numerical simulations of the model fit well with the empirical results. Our findings are helpful for discovering regular patterns of human behavior in on-line society and the evolution of the public opinion on the virtual as well as real society.

  4. On-Line Core Thermal-Hydraulic Model Improvement

    International Nuclear Information System (INIS)

    In, Wang Kee; Chun, Tae Hyun; Oh, Dong Seok; Shin, Chang Hwan; Hwang, Dae Hyun; Seo, Kyung Won

    2007-02-01

    The objective of this project is to implement a fast-running 4-channel based code CETOP-D in an advanced reactor core protection calculator system(RCOPS). The part required for the on-line calculation of DNBR were extracted from the source of the CETOP-D code based on analysis of the CETOP-D code. The CETOP-D code was revised to maintain the input and output variables which are the same as in CPC DNBR module. Since the DNBR module performs a complex calculation, it is divided into sub-modules per major calculation step. The functional design requirements for the DNBR module is documented and the values of the database(DB) constants were decided. This project also developed a Fortran module(BEST) of the RCOPS Fortran Simulator and a computer code RCOPS-SDNBR to independently calculate DNBR. A test was also conducted to verify the functional design and DB of thermal-hydraulic model which is necessary to calculate the DNBR on-line in RCOPS. The DNBR margin is expected to increase by 2%-3% once the CETOP-D code is used to calculate the RCOPS DNBR. It should be noted that the final DNBR margin improvement could be determined in the future based on overall uncertainty analysis of the RCOPS

  5. Utilities enticing customers to come on-line

    International Nuclear Information System (INIS)

    Anon

    2000-01-01

    The first tentative steps by electric utilities to offer customer services on-line is reported. While most of the on-line communications to date has been merely to present information about products and services, at least a few utilities, -- Newfoundland Power being one of them -- are now offering customers the opportunity to check on their account status, to make inquiries, and on a voluntary basis employees of the utility can receive their bills on the web. BC Hydro is even more advanced; it has offered a similar service since 1997. The option to pay bills at the BC Hydro website is coming shortly. U. S. utility companies are reported to be far more advanced in the use of the Internet; according to a study by Deloitte Consulting, U.S. utilities are advancing to the next stage wherein Web intermediaries will be offering 'shop bots' that do comparison shopping on behalf of a customer, including bidding for power on a customer's behalf at energy auctions, reverse auctions, where sellers are bidding for customers' services, and buyers clubs where customers join together to take advantage of volume buying power

  6. On-line monitoring and inservice inspection in codes

    International Nuclear Information System (INIS)

    Bartonicek, J.; Zaiss, W.; Bath, H.R.

    1999-01-01

    The relevant regulatory codes determine the ISI tasks and the time intervals for recurrent components testing for evaluation of operation-induced damaging or ageing in order to ensure component integrity on the basis of the last available quality data. In-service quality monitoring is carried out through on-line monitoring and recurrent testing. The requirements defined by the engineering codes elaborated by various institutions are comparable, with the KTA nuclear engineering and safety codes being the most complete provisions for quality evaluation and assurance after different, defined service periods. German conventional codes for assuring component integrity provide exclusively for recurrent inspection regimes (mainly pressure tests and optical testing). The requirements defined in the KTA codes however always demanded more specific inspections relying on recurrent testing as well as on-line monitoring. Foreign codes for ensuring component integrity concentrate on NDE tasks at regular time intervals, with time intervals scope of testing activities being defined on the basis of the ASME code, section XI. (orig./CB) [de

  7. Polar On-Line Acquisition Relay and Transmission System (POLARATS)

    Energy Technology Data Exchange (ETDEWEB)

    Yuracko, K.

    2004-07-15

    POLARATS (Polar On-Line Acquisition Relay And Transmission System) is being developed by YAHSGS LLC (YAHSGS) and Oak Ridge National Laboratory (ORNL) to provide remote, unattended monitoring of environmental parameters under harsh environmental conditions. In particular, instrumental design and engineering is oriented towards protection of human health in the Arctic, and with the additional goal of advancing Arctic education and research. POLARATS will obtain and transmit environmental data from hardened monitoring devices deployed in locations important to understanding atmospheric and aquatic pollutant migration as it is biomagnified in Arctic food chains. An Internet- and personal computer (PC)-based educational module will provide real time sensor data, on-line educational content, and will be integrated with workbooks and textbooks for use in middle and high school science programs. The educational elements of POLARATS include an Internet-based educational module that will instruct students in the use of the data and how those data fit into changing Arctic environments and food chains. POLARATS will: (1) Enable students, members of the community, and scientific researchers to monitor local environmental conditions in real time over the Internet; and (2) Provide additional educational benefits through integration with middle- and high-school science curricula. Information will be relayed from POLARATS devices to classrooms and libraries along with custom-designed POLARATS teaching materials that will be integrated into existing curricula to enhance the educational benefits realized from the information obtained.

  8. Aria Sardinia: the on line community joining tradition and innovatiom

    Directory of Open Access Journals (Sweden)

    Fabrizio Lao

    2005-12-01

    Full Text Available The "ARIA Sardinia" project (Network Actions for Italians Abroad has been especially designed to integrate and give value to the network of relationships between public administrations, local socio-economic stakeholders and Italian communities abroad, this goal to be pursued with the support of new technologies and learning approaches emerging within the context of on line interest communities. The general objective of the project is the development of competencies and knowledge, intended to combine specific technical skills with local "territorial knowledge", in a process where the strengthening and the dissemination of these forms of culture come from the prompt use of innovative tools. The main activities of the project are the actions intended to guide and assist entrepreneurs, associations, development projects' partners or promoters in the path of acquisition and dissemination of the competencies which are necessary to the involvement of Italians abroad into the internationalization process of Sardinian economy. ARIA Sardinia was funded by the Italian Foreign Affairs Ministry and the European Social Fund (FSE, within the framework of the National Operational Program for Technical Assistance and System Action (PON ATAS aimed at specific promotion initiatives and fostering of permanent links between Southern Italy economy and Italians living abroad. Keywords: on line community, networking, Italians abroad, Sardinian economy, Sardinia, culture.

  9. On-Line Core Thermal-Hydraulic Model Improvement

    Energy Technology Data Exchange (ETDEWEB)

    In, Wang Kee; Chun, Tae Hyun; Oh, Dong Seok; Shin, Chang Hwan; Hwang, Dae Hyun; Seo, Kyung Won

    2007-02-15

    The objective of this project is to implement a fast-running 4-channel based code CETOP-D in an advanced reactor core protection calculator system(RCOPS). The part required for the on-line calculation of DNBR were extracted from the source of the CETOP-D code based on analysis of the CETOP-D code. The CETOP-D code was revised to maintain the input and output variables which are the same as in CPC DNBR module. Since the DNBR module performs a complex calculation, it is divided into sub-modules per major calculation step. The functional design requirements for the DNBR module is documented and the values of the database(DB) constants were decided. This project also developed a Fortran module(BEST) of the RCOPS Fortran Simulator and a computer code RCOPS-SDNBR to independently calculate DNBR. A test was also conducted to verify the functional design and DB of thermal-hydraulic model which is necessary to calculate the DNBR on-line in RCOPS. The DNBR margin is expected to increase by 2%-3% once the CETOP-D code is used to calculate the RCOPS DNBR. It should be noted that the final DNBR margin improvement could be determined in the future based on overall uncertainty analysis of the RCOPS.

  10. The Automated Threaded Fastening Based on On-line Identification

    Directory of Open Access Journals (Sweden)

    Nicolas Ivan Giannoccaro

    2008-11-01

    Full Text Available The principle of the thread fastenings have been known and used for decades with the purpose of joining one component to another. Threaded fastenings are popular because they permit easy disassembly for maintenance, repair, relocation and recycling. Screw insertions are typically carried out manually. It is a difficult problem to automat. As a result there is very little published research on automating threaded fastenings, and most research on automated assembly focus on the peg-in-hole assembly problem. This paper investigates the problem of automated monitoring of the screw insertion process. The monitoring problem deals with predicting integrity of a threaded insertion, based on the torque vs. insertion depth curve generated during the insertions. The authors have developed an analytical model to predict the torque signature signals during self-tapping screw insertions. However, the model requires parameters on the screw dimensions and plate material properties are difficult to measure. This paper presents a study on on-line identification during screw fastenings. An identification methodology for two unknown parameter estimation during a self-tapping screw insertion process is presented. It is shown that friction and screw properties required by the model can be reliably estimated on-line. Experimental results are presented to validate the identification procedure.

  11. Calibration through on-line monitoring of instruments channels

    International Nuclear Information System (INIS)

    James, R.W.

    1996-01-01

    Plant technical specifications require periodic calibration of instrument channels, and this has traditionally meant calibration at fixed time intervals for nearly all instruments. Experience has shown that unnecessarily frequent calibrations reduce channel availability and reliability, impact outage durations, and increase maintenance costs. An alternative approach to satisfying existing requirements for periodic calibration consists of on-line monitoring and quantitative comparison of instrument channels during operation to identify instrument degradation and failure. A Utility Working Group has been formed by EPRI to support the technical activities necessary to achieve generic NRC acceptance of on-line monitoring of redundant instrument channels as a basis for determining when to perform calibrations. A topical report proposing NRC acceptance of this approach was submitted in August 1995, and the Working Group is currently resolving NRC technical questions. This paper describes the proposed approach and the current status of the topical report with regard to NRC review. While these activities will not preclude utilities from continuing to use existing calibration approaches, successful acceptance of this performance-based approach will allow utilities to substantially reduce the number of calibrations which are performed. Concurrent benefits will include reduced I ampersand C impact on outage durations and improved sensitivity to instrument channel performance

  12. On-line optimal control improves gas processing

    International Nuclear Information System (INIS)

    Berkowitz, P.N.; Papadopoulos, M.N.

    1992-01-01

    This paper reports that the authors' companies jointly funded the first phase of a gas processing liquids optimization project that has the specific purposes to: Improve the return of processing natural gas liquids, Develop sets of control algorithms, Make available a low-cost solution suitable for small to medium-sized gas processing plants, Test and demonstrate the feasibility of line control. The ARCO Willard CO 2 gas recovery processing plant was chosen as the initial test site to demonstrate the application of multivariable on-line optimal control. One objective of this project is to support an R ampersand D effort to provide a standardized solution to the various types of gas processing plants in the U.S. Processes involved in these gas plants include cryogenic separations, demethanization, lean oil absorption, fractionation and gas treating. Next, the proposed solutions had to be simple yet comprehensive enough to allow an operator to maintain product specifications while operating over a wide range of gas input flow and composition. This had to be a supervisors system that remained on-line more than 95% of the time, and achieved reduced plant operating variability and improved variable cost control. It took more than a year to study various gas processes and to develop a control approach before a real application was finally exercised. An initial process for C 2 and CO 2 recoveries was chosen

  13. Amdel on-line analyser at Rooiberg Tin Limited

    International Nuclear Information System (INIS)

    Owen, T.V.

    1987-01-01

    An Amdel on line analysis system was installed on the 'A' mine tin flotation plant at Rooiberg in April 1984. The motivation for the installation was made on account of the large variations in the feed grade to the plant and the resulting need for rapid operational adjustments to control concentrate grades thereby maximising the financial returns. An 'on-line' analyser system presented itself as a suitable alternative to the existing control method of smaller laboratory x-ray fluorescence analysers. On the system as installed at Rooiberg, two probes were fitted in each analysis zone, viz a density probe using high energy gamma radiation from a Cesium 127 source and a specific element absorption probe using low energy gamma radiation from a Americium 241 source. The signals as received from the probes are fed to a line receiver unit in the control room where a micro computer is doing the processing and prints out the information as required. Several advantages of this type of installation were gained at Rooiberg Tin Limited

  14. On-line Social Interactions and Executive Functions

    Directory of Open Access Journals (Sweden)

    Oscar eYbarra

    2012-04-01

    Full Text Available A successful social interaction requires fast, on-line, and active construction of an ever-changing mental-model of another’s person beliefs, expectations, emotions, and desires. It also requires the ability to inhibit inappropriate behaviors, problem-solve, take-turns, and pursue goals in a distraction-rich environment. All these tasks rely on executive functions (EF—working memory, attention/cognitive control, and inhibition. Executive functioning has long been viewed as relatively static. However, starting with recent reports of successful cognitive interventions, this view is changing and now EFs are seen as much more open to both short and long term training, warm-up, and exhaustion effects. Some of the most intriguing evidence comes from research showing how social interaction enhances performance on standard EF tests. Interestingly, the latest research indicates these EF benefits are selectively conferred by certain on-line, dynamic social interactions, which require participants to engage with another person and actively construct the model of their mind. We review this literature and highlight its connection with evolutionary and cultural theories emphasizing links between intelligence and social life.

  15. Project development and commercialisation of on-line analysis systems

    International Nuclear Information System (INIS)

    Watt, J.S.

    2000-01-01

    A project team first in the Australian Atomic Energy Commission (AAEC) and since 1982 in CSIRO has developed many on-line analysis systems for the mineral and energy industries. The development of these projects, usually lasting 7-10 years, has followed a common pattern of laboratory R and D, field trials, commercialisation and technology transfer. This successful pattern is illustrated using examples of the development of systems for the on-line analysis of mineral slurries, for determination of the ash content of coal on conveyors, and for determination of the flow rates of oil, water and gas in pipelines. The first two systems, licensed to Australian companies, are used world-wide. They are now the market leaders for radioisotope gauges in their application field. The third, the multiphase flow meter, was licensed in 1997 to an international company. This meter has even greater potential than the other two systems for economic benefit from its use and for numbers of installations. (author)

  16. Increased Cortical Thickness in Professional On-Line Gamers

    Science.gov (United States)

    Hyun, Gi Jung; Shin, Yong Wook; Kim, Bung-Nyun; Cheong, Jae Hoon; Jin, Seong Nam

    2013-01-01

    Objective The bulk of recent studies have tested whether video games change the brain in terms of activity and cortical volume. However, such studies are limited by several factors including cross-sectional comparisons, co-morbidity, and short-term follow-up periods. In the present study, we hypothesized that cognitive flexibility and the volume of brain cortex would be correlated with the career length of on-line pro-gamers. Methods High-resolution magnetic resonance scans were acquired in twenty-three pro-gamers recruited from StarCraft pro-game teams. We measured cortical thickness in each individual using FreeSurfer and the cortical thickness was correlated with the career length and the performance of the pro-gamers. Results Career length was positively correlated with cortical thickness in three brain regions: right superior frontal gyrus, right superior parietal gyrus, and right precentral gyrus. Additionally, increased cortical thickness in the prefrontal cortex was correlated with winning rates of the pro-game league. Increased cortical thickness in the prefrontal and parietal cortices was also associated with higher performance of Wisconsin Card Sorting Test. Conclusion Our results suggest that in individuals without pathologic conditions, regular, long-term playing of on-line games is associated with volume changes in the prefrontal and parietal cortices, which are associated with cognitive flexibility. PMID:24474988

  17. Power plant experience with artificial intelligence based, on-line diagnostic systems

    International Nuclear Information System (INIS)

    Osborne, R.L.; Coffman, M.

    1987-01-01

    The utility industry is entering a period when generation equipment availability becomes increasingly critical due to the lack of new power plants being planned and built. The increasing percentage of all electric homes adding to peak demands requires more plant equipment to be used in a cyclic duty mode. Availability is on the increase with forced and planned maintenance hours decreasing. Factors that are contributing to this improvement are new units coming on-line with the latest in technology coupled with the installation of retrofit components containing that same technology such as the Rigi-Flex generators and ruggedized turbine rotors. In conjunction with hardware advances, technology advancements in monitoring and diagnostics are permitting the identification of potential malfunctions so that corrective actions can be taken, thus preventing lengthy outages. It is this last area that this paper will address

  18. Application of a Mechanistic Model as a Tool for On-line Monitoring of Pilot Scale Filamentous Fungal Fermentation Processes - The Importance of Evaporation Effects

    DEFF Research Database (Denmark)

    Mears, Lisa; Stocks, Stuart M.; Albæk, Mads Orla

    2017-01-01

    A mechanistic model-based soft sensor is developed and validated for 550L filamentous fungus fermentations operated at Novozymes A/S. The soft sensor is comprised of a parameter estimation block based on a stoichiometric balance, coupled to a dynamic process model. The on-line parameter estimation...... a historical dataset of eleven batches from the fermentation pilot plant (550L) at Novozymes A/S. The model is then implemented on-line in 550L fermentation processes operated at Novozymes A/S in order to validate the state estimator model on fourteen new batches utilizing a new strain. The product...... block models the changing rates of formation of product, biomass, and water, and the rate of consumption of feed using standard, available on-line measurements. This parameter estimation block, is coupled to a mechanistic process model, which solves the current states of biomass, product, substrate...

  19. Self-deformation in a direct current driven helium jet micro discharge

    Energy Technology Data Exchange (ETDEWEB)

    Xu, S. F.; Zhong, X. X., E-mail: xxzhong@sjtu.edu.cn [State Key Laboratory of Advanced Optical Communication Systems and Networks and Key Laboratory for Laser Plasmas (Ministry of Education), Department of Physics and Astronomy, Shanghai Jiao Tong University, Shanghai 200240 (China)

    2016-01-15

    We report on the experimental observation of three dimensional self-deformation in an atmospheric micro discharge of the helium microjet through a tube into the ambient air upon a water electrode. The geometry of the discharge system is axial symmetric. While decreasing the discharge current, three dimensional collective motion of plasma filaments is directly observed. The three dimensional configuration of the discharge self changed from an axial symmetrical horn to a rectangular horn when the water acts as a cathode.

  20. Self-deformation in a direct current driven helium jet micro discharge

    Science.gov (United States)

    Xu, S. F.; Zhong, X. X.

    2016-01-01

    We report on the experimental observation of three dimensional self-deformation in an atmospheric micro discharge of the helium microjet through a tube into the ambient air upon a water electrode. The geometry of the discharge system is axial symmetric. While decreasing the discharge current, three dimensional collective motion of plasma filaments is directly observed. The three dimensional configuration of the discharge self changed from an axial symmetrical horn to a rectangular horn when the water acts as a cathode.

  1. Self-deformation in a direct current driven helium jet micro discharge

    International Nuclear Information System (INIS)

    Xu, S. F.; Zhong, X. X.

    2016-01-01

    We report on the experimental observation of three dimensional self-deformation in an atmospheric micro discharge of the helium microjet through a tube into the ambient air upon a water electrode. The geometry of the discharge system is axial symmetric. While decreasing the discharge current, three dimensional collective motion of plasma filaments is directly observed. The three dimensional configuration of the discharge self changed from an axial symmetrical horn to a rectangular horn when the water acts as a cathode

  2. On-line determination of moisture in coal and coke

    International Nuclear Information System (INIS)

    Cutmore, N.G.; Sowerby, B.D.

    1987-01-01

    The CSIRO Division of Mineral Engineering is developing various techniques for the on-line determination of moisture in coal and coke, and some instruments are now commercially available. These techniques permit accurate and rapid determination of moisture in materials directly on conveyor belts or in bins. The most promising techniques for direct on-belt measurement of moisture in coal are capacitance and microwave transmission. A non-contacting under-belt capacitance and gamma-ray backscatter technique has determined moisture in coal to better than 0.5 wt% in field tests. CSIRO is developing a fast neutron and gamma-ray transmission technique, which is proving very accurate in laboratory tests. This technique overcomes many of the limitations of thermal neutrons moisture gauges

  3. On-line monitoring system for utility boiler diagnostics

    International Nuclear Information System (INIS)

    Radovanovic, P.M.; Afgan, N.H.; Caralho, M.G.

    1997-01-01

    The paper deals with the new developed modular type Monitoring System for Utility Boiler Diagnostics. Each module is intended to assess the specific process and can be used as a stand alone application. Four modules are developed, namely: LTC - module for the on-line monitoring of parameters related to the life-time consumption of selected boiler components; TRD - module for the tube rupture detection by the position and working fluid Ieakage quantity; FAM - module for the boiler surfaces fouling (slagging) assessment and FLAP - module for visualization of the boiler furnace flame position. All four modules are tested on respective pilot plants built oil the 200 and 300 MWe utility boilers. Monitoring System is commercially available and can be realized in any combination of its modules depending on demands induced by the operational problems of specific boiler. Further development of Monitoring System is performed in accordance with the respective EU project on development of Boiler Expert System. (Author)

  4. On-line Certification for All: The PINVOX Algorithm

    Directory of Open Access Journals (Sweden)

    E Canessa

    2012-09-01

    Full Text Available A protoype algorithm: PINVOX (“Personal Identification Number by Voice" for on-line certification is introduced to guarantee that scholars have followed, i.e., listened and watched, a complete recorded lecture with the option of earning a certificate or diploma of completion after remotely attending courses. It is based on the injection of unique, randomly selected and pre-recorded integer numbers (or single letters or words within the audio trace of a video stream at places where silence is automatically detected. The certificate of completion or “virtual attendance” is generated on-the-fly after the successful identification of the embedded PINVOX code by a video viewer student.

  5. On-line control of the nonlinear dynamics for synchrotrons

    Science.gov (United States)

    Bengtsson, J.; Martin, I. P. S.; Rowland, J. H.; Bartolini, R.

    2015-07-01

    We propose a simple approach to the on-line control of the nonlinear dynamics in storage rings, based on compensation of the nonlinear resonance driving terms using beam losses as the main indicator of the strength of a resonance. The correction scheme is built on the analysis of the resonance driving terms in first perturbative order and on the possibility of using independent power supplies in the sextupole magnets, which is nowadays present in many synchrotron light sources. Such freedom allows the definition of "smart sextupole knobs" attacking each resonance separately. The compensation scheme has been tested at the Diamond light source and proved to be effective in opening up the betatron tune space, resonance free, available to the electron beam and to improve the beam lifetime.

  6. On-line control of the nonlinear dynamics for synchrotrons

    Directory of Open Access Journals (Sweden)

    J. Bengtsson

    2015-07-01

    Full Text Available We propose a simple approach to the on-line control of the nonlinear dynamics in storage rings, based on compensation of the nonlinear resonance driving terms using beam losses as the main indicator of the strength of a resonance. The correction scheme is built on the analysis of the resonance driving terms in first perturbative order and on the possibility of using independent power supplies in the sextupole magnets, which is nowadays present in many synchrotron light sources. Such freedom allows the definition of “smart sextupole knobs” attacking each resonance separately. The compensation scheme has been tested at the Diamond light source and proved to be effective in opening up the betatron tune space, resonance free, available to the electron beam and to improve the beam lifetime.

  7. On-line monitoring system for I-131 manufacturing labs

    International Nuclear Information System (INIS)

    Osovizky, A.; Malamud, Y.; Paran, Y.; Tal, N.; Turgeman, S.; Weinstein, M.

    1997-01-01

    An on-line monitoring and safety system has been installed in a lab for manufacturing 1-131 capsules for nuclear medicine use. Production of up to 100mCi batches is performed in shielded glove boxes. The safety system is based on a unique, 'Medi SMARTS' system (Medical Survey Mapping Automatic Radiation Tracing System), that collects continuously the radiation measurements for processing, display, and storage for future retrieval. Radiation is measured by GM tubes, data is transferred to a data processing unit, and then via a RS-485 communication line to a computer. In addition to the operational advantages and radiation levels storage, the system is being evaluated for the purpose of identifying risky stages in the process. (authors)

  8. Issues for Bringing Electron Beam Irradiators On-Line

    International Nuclear Information System (INIS)

    Kaye, R.J.; Turman, B.N.

    1999-01-01

    Irradiation of red meat and poultry has been approved by the U.S. FDA, and the U.S. Department of Agriculture's rule for processing red meat is out for comment. Looking beyond the current issues of packaging materials, labeling, and consumer acceptance, this paper reviews the next step of implementation and how to remove, or at least reduce, the barriers to utilization. Polls of the user community identified their requirements for electron beam or x-ray processing of meat or poultry and their concerns about implementation for on-line processing. These needs and issues are compared to the capabilities of the accelerator industry. The critical issues of beam utilization and dose uniformity, factors affecting floor space requirements, and treatment costs are examined

  9. On-line fatigue monitoring system for reactor pressure vessel

    International Nuclear Information System (INIS)

    Tokunaga, K.; Sakai, A.; Aoki, T.; Ranganath, S.; Stevens, G.L.

    1994-01-01

    A workstation-based, on-line fatigue monitoring system for tracking fatigue usage applied to an operating boiling water reactor (BWR), Tsuruga Unit-1, is described. The system uses the influence function approach and determines component stresses using temperature, pressure, and flow rate data that are made available via signal taps from previously existing plant sensors. Using plant unique influence functions developed specifically for the feedwater nozzle location, the system calculates stresses as a function of time and computed fatigue usage. The analysis method used to compute fatigue usage complies with MITI Code Notification No.501. Fatigue usage results for an entire fuel cycle are presented and compared to assumed design basis events to confirm that actual plant thermal duty is significantly less severe than originally estimated in the design basis stress report. As a result, the system provides the technical basis to more accurately evaluate actual reactor conditions as well as the justification for plant life extension. (author)

  10. On-line fatigue monitoring and probabilistic assessment of margins

    Energy Technology Data Exchange (ETDEWEB)

    Fournier, I. [Electricite de France, 93 - Saint-Denis (France). Direction des Etudes et Recherches; Morilhat, P. [Electricite de France, 93 - Saint-Denis (France). Direction des Etudes et Recherches

    1995-01-01

    An on-line computer-aided system has been developed by Electricite de France, the French utility, for fatigue monitoring of critical locations in the nuclear steam supply system. This tool, called a fatigue meter, includes as input data plant parameters and is based on some conservative assumptions at several steps of the damage assessment (thermal boundary conditions, stress computation,..). In this paper we present recent developments performed towards a better assessment of margins involved in the complete analysis. The methodology is illustrated with an example showing the influence of uncertainty in plant parameters on the final stress computed at a pressurized water reactor 900MW unit pressurizer surge line nozzle. A second example is shown to illustrate the possibility of defining some transient archetypes. ((orig.)).

  11. On-line Monitoring of Instrumentation in Research Reactors

    International Nuclear Information System (INIS)

    2017-12-01

    This publication is the result of a benchmarking effort undertaken under the IAEA coordinated research project on improved instrumentation and control (I&C) maintenance techniques for research reactors. It lays the foundation for implementation of on-line monitoring (OLM) techniques and establishment of the validity of those for improved maintenance practices in research reactors for a number of applications such as change to condition based calibration, performance monitoring of process instrumentation systems, detection of process anomalies and to distinguish between process problems/effects and instrumentation/sensor issues. The techniques and guidance embodied in this publication will serve the research reactor community in providing the technical foundation for implementation of OLM techniques. It is intended to be used by Member States to implement I&C maintenance and to improve performance of research reactors.

  12. On-line control of nuclear fuel reprocessing

    International Nuclear Information System (INIS)

    Parus, I.; Kierzek, J.; Zoltowski, T.

    1977-01-01

    The development trends in the field of chemical processes control and the present state of the development of continuous composition analysers has been described. On this background the peculiarities of on-line control methods for spent nuclear fuel reprocessing have been discussed. The measuring methods for direct and indirect determination of chemical composition and nuclear safety are reviewed in detail. The review comprises such methods as: measurement of α, γ and neutron radiation emitted both by nuclides present in technological solutions and using external sources of different radiation, X-ray fluorescence, measurements of physicochemical parameters connected with the composition (pH, density, electrical conductivity), polarography and spectrophotometry. At the end of this review some new trends in process control based on dynamic process models have been presented. (author)

  13. The Task Manager for the LHCb On-Line Farm

    CERN Document Server

    Bonifazi, F; Carbone, A; Galli, D; Gregori, D; Marconi, U; Peco, G; Vagnoni, V

    2004-01-01

    The Task Manager is a utility to start, stop and list processes on the on-line farm. Each process started by the Task Manager has a string environment variable set, named UTGID (User defined unique Thread Group Identifier) which allows to identify the process. The Task Manager uses the UTGID to list the running processes and to identify the processes to be stopped. It has also the ability to start a process using a particular user name and to set the scheduler type and the priority for the process itself. The Task Manager package includes a Linux DIM server (tmSrv), four Linux command line DIM clients (tmStart, tmLs, tmKill and tmStop) and a JCOP (Joint Control Project) PVSS client.

  14. On-line Corrosion Monitoring in District Heating Systems

    DEFF Research Database (Denmark)

    Richter, Sonja; Thorarinsdottir, R.I.; Hilbert, Lisbeth Rischel

    2005-01-01

    The corrosion control in district heating systems is today performed primarily with control of the water quality. The corrosion rate is kept low by assuring low dissolved oxygen concentration, high pH and low conductivity. Corrosion failures can occur, e.g. as a result of unknown oxygen ingress, ......, precipitation of deposits or crevices. The authors describe methods used for on-line monitoring of corrosion, cover the complications and the main results of a Nordic project.......The corrosion control in district heating systems is today performed primarily with control of the water quality. The corrosion rate is kept low by assuring low dissolved oxygen concentration, high pH and low conductivity. Corrosion failures can occur, e.g. as a result of unknown oxygen ingress...

  15. NOASYS, a system for on-line noise analysis

    International Nuclear Information System (INIS)

    Massier, H.

    1978-07-01

    This report describes NOASYS, a versatile NOise Analysis SYStem for digital on-line signal processing. The system based on a minicomputer, was originally developed for the analysis of noise signals from nuclear reactors. NOASYS computes various statistical functions e.g. cross- und auto-correlation functions and power spectral densities resp., which may be used for reactor diagnosis and malfunction detection. The system processes up to 16 analog signals with a maximum sampling frequency of 100 kcps (1 channel). The processing of the sampled data is done by a number of software tasks, which may be called from a teletype or linked together for specific measuring programs. The standard configuration contains the often used processing routines e.g. Fast Fourier Transform, complex multiplication, summation etc. In addition NOASYS may be extended by users own tasks (in Assembler or Fortran) to fit for specific applications. (orig.) 891 HP [de

  16. On-line efficiency optimization of a synchronous reluctance motor

    Energy Technology Data Exchange (ETDEWEB)

    Lubin, Thierry; Razik, Hubert; Rezzoug, Abderrezak [Groupe de Recherche en Electrotechnique et Electronique de Nancy, GREEN, CNRS-UMR 7037, Universite Henri Poincare, BP 239, 54506 Vandoeuvre-les-Nancy Cedex (France)

    2007-04-15

    This paper deals with an on-line optimum-efficiency control of a synchronous reluctance motor drive. The input power minimization control is implemented with a search controller using Fibonacci search algorithm. It searches the optimal reference value of the d-axis stator current for which the input power is minimum. The input power is calculated from the measured dc-bus current and dc-bus voltage of the inverter. A rotor-oriented vector control of the synchronous reluctance machine with the optimization efficiency controller is achieved with a DSP board (TMS302C31). Experimental results are presented to validate the proposed control methods. It is shown that stability problems can appear during the search process. (author)

  17. Development of on-line monitoring system using smart material

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jin Kyung; Lee, Sang Pill; Park, Yi Hyun [Dongeui Univ., Busan (Korea, Republic of); Park, Young Chul [Donga Univ., Busan (Korea, Republic of)

    2003-07-01

    A hot press method was used to create the optimal fabrication condition for a Shape Memory Alloy(SMA) composite. The bonding strength between the matrix and the reinforcement within the SMA composite by the hot press method was more increased by cold rolling. In this study, the objective was to develop an on-line monitoring system in order to prevent the crack initiation and propagation by shape memory effect in SMA composite. Shape memory effect was used to prevent the SMA composite from crack propagation. For this system an optimal AE parameter should be determined according to the degree of damage and crack initiation. When the SMA composite was heated by the plate heater attached at the composite, the propagating cracks could be controlled by the compressive force of SMA.

  18. Development of on-line monitoring system using smart material

    International Nuclear Information System (INIS)

    Lee, Jin Kyung; Lee, Sang Pill; Park, Yi Hyun; Park, Young Chul

    2003-01-01

    A hot press method was used to create the optimal fabrication condition for a Shape Memory Alloy(SMA) composite. The bonding strength between the matrix and the reinforcement within the SMA composite by the hot press method was more increased by cold rolling. In this study, the objective was to develop an on-line monitoring system in order to prevent the crack initiation and propagation by shape memory effect in SMA composite. Shape memory effect was used to prevent the SMA composite from crack propagation. For this system an optimal AE parameter should be determined according to the degree of damage and crack initiation. When the SMA composite was heated by the plate heater attached at the composite, the propagating cracks could be controlled by the compressive force of SMA

  19. Issues for Bringing Electron Beam Irradiators On-Line

    Energy Technology Data Exchange (ETDEWEB)

    Kaye, R.J.; Turman, B.N.

    1999-04-20

    Irradiation of red meat and poultry has been approved by the U.S. FDA, and the U.S. Department of Agriculture's rule for processing red meat is out for comment. Looking beyond the current issues of packaging materials, labeling, and consumer acceptance, this paper reviews the next step of implementation and how to remove, or at least reduce, the barriers to utilization. Polls of the user community identified their requirements for electron beam or x-ray processing of meat or poultry and their concerns about implementation for on-line processing. These needs and issues are compared to the capabilities of the accelerator industry. The critical issues of beam utilization and dose uniformity, factors affecting floor space requirements, and treatment costs are examined.

  20. Escapist Motives for Playing On-Line Games

    DEFF Research Database (Denmark)

    Sudzina, Frantisek; Razmerita, Liana

    2012-01-01

    Social games have become popular along with the tremendous growth of social networking sites, esp. Facebook. There is a gap in literature on what motivates people to play Facebook games. This paper studies social games usage behavior of students. We focus on escapist reasons, based on Warmelink...... of escapist motives for playing Facebook and other on-line games, we investigate how they are linked to demographic data such as: age, gender, place of origin, along with other social interactions patterns and social network usage behavior, current gaming status and an estimate of gaming time. According...... to our study, only 10% of respondents, who have started to play Facebook games, continued to play them. The most important motives for playing games is mundane breaking, the second reason is pleasure seeking, the third is stress relieving, and the least important is imagination conjuring....

  1. Configuration Database for BaBar On-line

    International Nuclear Information System (INIS)

    Salnikov, Andrei

    2003-01-01

    The configuration database is one of the vital systems in the BaBar on-line system. It provides services for the different parts of the data acquisition system and control system, which require run-time parameters. The original design and implementation of the configuration database played a significant role in the successful BaBar operations since the beginning of experiment. Recent additions to the design of the configuration database provide better means for the management of data and add new tools to simplify main configuration tasks. We describe the design of the configuration database, its implementation with the Objectivity/DB object-oriented database, and our experience collected during the years of operation

  2. 3rd Computer Science On-line Conference

    CERN Document Server

    Senkerik, Roman; Oplatkova, Zuzana; Silhavy, Petr; Prokopova, Zdenka

    2014-01-01

    This book is based on the research papers presented in the 3rd Computer Science On-line Conference 2014 (CSOC 2014).   The conference is intended to provide an international forum for discussions on the latest high-quality research results in all areas related to Computer Science. The topics addressed are the theoretical aspects and applications of Artificial Intelligences, Computer Science, Informatics and Software Engineering.   The authors provide new approaches and methods to real-world problems, and in particular, exploratory research that describes novel approaches in their field. Particular emphasis is laid on modern trends in selected fields of interest. New algorithms or methods in a variety of fields are also presented.   This book is divided into three sections and covers topics including Artificial Intelligence, Computer Science and Software Engineering. Each section consists of new theoretical contributions and applications which can be used for the further development of knowledge of everybod...

  3. On-line Ciphers and the Hash-CBC Constructions

    DEFF Research Database (Denmark)

    Bellare, M.; Boldyreva, A.; Knudsen, Lars Ramkilde

    2012-01-01

    We initiate a study of on-line ciphers. These are ciphers that can take input plaintexts of large and varying lengths and will output the i th block of the ciphertext after having processed only the first i blocks of the plaintext. Such ciphers permit length-preserving encryption of a data stream...... with only a single pass through the data. We provide security definitions for this primitive and study its basic properties. We then provide attacks on some possible candidates, including CBC with fixed IV. We then provide two constructions, HCBC1 and HCBC2, based on a given block cipher E and a family...... of computationally AXU functions. HCBC1 is proven secure against chosen-plaintext attacks assuming that E is a PRP secure against chosen-plaintext attacks, while HCBC2 is proven secure against chosen-ciphertext attacks assuming that E is a PRP secure against chosen-ciphertext attacks....

  4. On-line defected fuel monitoring using GFP data

    International Nuclear Information System (INIS)

    Livingstone, S.; Lewis, B.J.

    2008-01-01

    This paper describes the initial development of an on-line defected fuel diagnostic tool. The tool is based on coolant activity, and uses a quantitative and qualitative approach from existing mechanistic fission product release models, and also empirical rules based on commercial and experimental experience. The model departs from the usual methodology of analyzing steady-state fission product coolant activities, and instead uses steady-state fission product release rates calculated from the transient coolant activity data. An example of real-time defected fuel analysis work is presented using a prototype of this tool with station data. The model is in an early developmental stage, and this paper demonstrates the promising potential of this technique. (author)

  5. An on-line advanced plant simulator (OLAPS)

    International Nuclear Information System (INIS)

    Samuels, J.W.

    1989-01-01

    A PC based on-line advanced plant simulator (OLAPS) for high quality simulations of Portland General Electric's Trojan Nuclear Facility is presented. OLAPS is designed to simulate the thermal-hydraulics of the primary system including core, steam generators, pumps, piping and pressurizer. The simulations are based on a five equation model that has two mass equations, two energy equations, two energy equations, and one momentum equation with a drift flux model to provide closure. A regionwise point reactor kinetics model is used to model the neutron kinetics in the core. The conservation equations, constitutive models and the numerical methods used to solve them are described. OLAPS results are compared with data from chapter 15 of the Trojan Nuclear Facility's final safety analysis report

  6. The Monitor System for the LHCb on-line farm

    CERN Document Server

    Bonifazi, F; Carbone, A; Galli, D; Gregori, D; Marconi, U; Peco, G; Vagnoni, V

    2005-01-01

    The aim of the LHCb on-line farm Monitor System is to keep under control all the working indicators which are relevant for the farm operation, and to set the appropriate alarms whenever an error or a critical condition comes up. Since the most stressing tasks of the farm are the data transfer and processing, relevant indicators includes the CPU and the memory load of the system, the network interface and the TCP/IP stack parameters, the rates of the interrupts raised by the network interface card and the detailed status of the running processes. The monitoring of computers’ physical conditions (temperatures, fan speeds and motherboard voltages) are the subject of a separate technical note, since they are accessed in a different way, by using the IPMI protocol.

  7. On-line monitoring of main coolant pump seals

    International Nuclear Information System (INIS)

    Stevens, D.M.; Spencer, J.W.; Morris, D.J.; Glass, S.W.; Sommerfield, G.A.; Harrison, D.

    1984-06-01

    The Babcock and Wilcox Company has developed and implemented a Reactor Coolant Pump Monitoring and Diagnostic System (RCPM and DS). The system has been installed at Toledo Edison Company's Davis-Besse Nuclear Power Station Unit 1. The RCPM and PS continuously monitors a number of indicators of pump performance and notifies the plant operator of out-of-tolerance conditions or pump performance trending toward out-of-tolerance conditions. Pump seal parameters being monitored include pump internal pressures, temperatures, and flow rates. Rotordynamic performanvce and plant operating conditions are also measured with a variety of dynamic sensors. This paper describes the implementation of the system and the results of on-line monitoring of four RC pumps

  8. PHEBUS on-line aerosol monitor development test program

    International Nuclear Information System (INIS)

    Sprenger, M.H.; Pentecost, C.G.

    1992-03-01

    EG ampersand G Idaho, Inc. developed an on-line aerosol monitor (OLAM) for the French PHEBUS Fission Product Project. Part of the development was to manufacture and test an OLAM prototype. This report presents the results of the testing which determined the mechanical integrity of the monitor at operating temperature and pressure and performed a preliminary test of the optical system. A series of twenty different tests was conducted during the prototype testing sequence. Since no leaks were detected, the OLAM demonstrated that it could provide a pressure boundary at required test conditions. The optical and electrical system also proved its integrity by exceeding the design requirement of less than 105 optical signal drift during an actual two-hour test sequence

  9. On line isotopic separator test benches at GANIL

    International Nuclear Information System (INIS)

    Anne, R.; Bru, B.; Joubert, A.; Leroy, R.; Obert, J.; Putaux, J.C.; Liang, C.F.; Paris, P.; Orr, N.; Steckmeyer, J.C.

    1993-01-01

    A first version of isotopic separator on line test bench has been built in order to test the feasibility of the production of radioactive species from 96 MeV/u of 20 Ne impinging a thick target of MgO. This test bench was equipped with a very compact ECR ion source (Nanogan) entirely made from permanent magnets and operating at 10 Ghz. 18 Ne 2,4+ ; 19N e 1,2,3,4+ and 23,24 Ne 1+ has been produced and ionized. A new more performing separator (SIRa) allowing the use of different types of ion sources will be completed by the end of 1993. (author) 4 refs., 4 figs., 1 tab

  10. Semi-continuous on-line uranium ore analyzer

    International Nuclear Information System (INIS)

    Campbell, P.; Gurdy, E.M.; Hatchowski, L.

    1984-01-01

    The efficient process control of a uranium mill and its associated mining operation requires a nearly continuous knowledge of the uranium concentration in the ore. Generally, the approach is to use laboratory assays of grab samples from the mill feed belt. In some cases, elaborate and expensive systems have been used to ensure random sampling, but even with these systems, mass-balance discrepancies still exist. There is a requirement for an on-line instrument that can give a prompt, accurate analysis of a large portion of the feed stock. The authors have recently evaluated a laboratory system that achieves these goals using neutron activation and delayed neutron counting. The development of the on-line uranium ore analyzer is a consequence of previous work done at the Whiteshell Nuclear Research Establishment (WNRE) (Campbell et al., 1978 and 1981), and is based on the emission of delayed neutrons after the neutron irradiation of fissionable materials. The mechanism of delayed neutron emission has been described (Keepin, 1965), but briefly is as follows. The fission fragments resulting from irradiation are in an excited state. Certain of these delayed fission products, precursors, decay to a more stable state by the emission of a delayed neutron. The delayed neutrons can be divided into six groups with effective half-lives ranging from 0.2-55 sec. It is important to note that more than 50% of the delayed neutrons are emitted within the first 6 sec after irradiation; this has an influence on the design of the analysis instrument

  11. PHENIX On-Line Distributed Computing System Architecture

    International Nuclear Information System (INIS)

    Desmond, Edmond; Haggerty, John; Kehayias, Hyon Joo; Purschke, Martin L.; Witzig, Chris; Kozlowski, Thomas

    1997-01-01

    PHENIX is one of the two large experiments at the Relativistic Heavy Ion Collider (RHIC) currently under construction at Brookhaven National Laboratory. The detector consists of 11 sub-detectors, that are further subdivided into 29 units (''granules'') that can be operated independently, which includes simultaneous data taking with independent data streams and independent triggers. The detector has 250,000 channels and is read out by front end modules, where the data is buffered in a pipeline while awaiting the level trigger decision. Zero suppression and calibration is done after the level accept in custom built data collection modules (DCMs) with DSPs before the data is sent to an event builder (design throughput of 2 Gb/sec) and higher level triggers. The On-line Computing Systems Group (ONCS) has two responsibilities. Firstly it is responsible for receiving the data from the event builder, routing it through a network of workstations to consumer processes and archiving it at a data rate of 20 MB/sec. Secondly it is also responsible for the overall configuration, control and operation of the detector and data acquisition chain, which comprises the software integration for several thousand custom built hardware modules. The software must furthermore support the independent operation of the above mentioned granules, which includes the coordination of processes that run in 60-100 VME processors and workstations. ONOS has adapted the Shlaer- Mellor Object Oriented Methodology for the design of the top layer software. CORBA is used as communication layer between the distributed objects, which are implemented as asynchronous finite state machines. We will give an overview of the PHENIX online system with the main focus on the system architecture, software components and integration tasks of the On-line Computing group ONCS and report on the status of the current prototypes

  12. Progress and performance of on-line analyzers of coal

    International Nuclear Information System (INIS)

    Spencer, C.M.; Brown, D.R.; Gozani, T.; Bozorgmanesh, H.; Bernatowicz, H.; Tassicker, O.J.; Karlson, F.

    1982-01-01

    This paper describes the past year's progress in the laboratory testing of the most comprehensive Nucoalyzer, the CONAC, and the performance of a Nucoalyzer-Sulfurmeter in special field tests. Previous papers and presentations provide more detailed background information. The near real-time analysis provided by a Nucoalyzer can be used in a variety of strategies to optimize efficiency of coal use. Nucoalyzers can be used to monitor coal deliveries and achieve uniformity in coal storage and recovery. In a coal cleaning plant, on-line analysis with a Nucoalyzer can lead to optimum Btu recovery while meeting specifications for the washed coal. A Nucoalyzer can monitor the blending of different coals to maintain a key cosntituent such as sulfur below a specified level, or can predict sulfur dioxide emissions, allowing feed-forward control to gas scrubbers and precipitators. Variability in coal feed to the boiler can lead to gross changes in thermodynamic efficiency in combustion. In addition, fouling and slagging incidents due to poor coal quality cause costly boiler shutdowns and maintenance. Nucoalyzer monitoring of key constituents and Btu in the coal feed allows operators to adjust boiler parameters for increased efficiency. To summarize, the primary advantages of Nucoalyzers relate to their ability to quickly identify changes in coal composition so that adjustments can be made in a timely manner to accommodate these changes in the process being monitored. Nucoalyzers are the only instruments available that can monitor the coal (for ash, Btu, sulfur, etc.) on-line and provide real-time continuous results. One Nucoalyzer is already working in the field, and by the time of the next Symposium we will have had performance reports on two more

  13. On-line chemical sensors for applications in fast reactors

    International Nuclear Information System (INIS)

    Jayaraman, V.

    2015-01-01

    Hydrogen sensors are essential components of fast reactor sodium circuits. These sensors are needed in fast reactors for the immediate detection of any steam leak into sodium during reactor operation which can lead to failure of steam generator. Depending on the operating power of the reactor, sodium-water reaction results in either an increase in dissolved hydrogen level in sodium or an increase in hydrogen content of argon cover gas used above sodium coolant. Hence, on-line monitoring of hydrogen continuously in sodium and cover circuits helps in detection of any steam leak. In the event of accidental leak of high temperature sodium, it reacts with oxygen and moisture in air leading to sodium fires. These fires produce sodium aerosol containing oxides of sodium (Na 2 O and Na 2 O 2 ) and NaOH. For early detection of sodium fires, sensor systems based on sodium ionization detector, pH measurement and modulation of conductivity of graphite films are known in the literature. This presentation deals with the development of on-line sensors for these two applications. A diffusion based sensor using a thin walled nickel coil at 773 K and a sensitive thermal conductivity detector (TCD) has been developed for monitoring hydrogen levels in argon cover gas. This sensor has a lower detection limit of 30 ppm of hydrogen in argon. To extend the detection limit of the sensor, a surface conductivity based sensor has been developed which makes use of a thin film of semi-conducting tin oxide. Integration of this sensor with the TCD, can extend the lower detection limit to 2 ppm of hydrogen in cover gas. Electrochemical sensor based on sodium-beta-alumina has been designed, fabricated and its performance in laboratory and industrial environment was evaluated. This paper presents the logical development of these sensors highlighting their merits and limitations

  14. Review of Worcestershire On-line Fabric Type Series website

    Directory of Open Access Journals (Sweden)

    Beverley Nenk

    2003-06-01

    Full Text Available The study of archaeological ceramics is advanced through the creation and development of regional and national pottery type-series, which contain samples of each type of pottery identified from a particular area or region. Pottery researchers working in any period, from prehistoric to post-medieval, require access to such type-series, and to their associated data, in order to be able to advance the identification of all types of pottery, not only those types produced in the local area, but those produced in surrounding regions, as well as those imported from abroad. The publication of such type-series, as well as their accessibility to researchers, is essential if the information they contain is to be disseminated. The development of the Worcestershire On-Line Fabric Type Series is the first stage in a remarkable project designed to make the complete fabric and form type series for Worcestershire ceramics accessible on the internet. As part of the Historic Environment Record for Worcestershire, formerly the Sites and Monuments Record, it is designed to improve access to finds and environmental data, with the aim of encouraging and facilitating research. Funded by Worcestershire County Council as part of its commitment to e-government, it is being developed by Worcestershire County Council Archaeology Service with OxfordArchDigital. It is one of a proposed series of on-line specialist resources (to include, for example, clay pipes, environmental archaeology, flint tools, historic buildings, which are also designed to stand alone as research tools. The ceramics website is the first part of Pottery in Perspective, a web-based project to provide information on the pottery used and made in Worcestershire from prehistory to c. 1900AD.

  15. Data correlation in on-line solid-phase extraction-gas chromatography-atomic emission/mass spectrometric detection of unknown microcontaminants

    NARCIS (Netherlands)

    Hankemeier, Th.; Rozenbrand, J.; Abhadur, M.; Vreuls, J.J.; Brinkman, U.A.Th.

    1998-01-01

    A procedure is described for the (non-target) screening of hetero-atom-containing compounds in tap and waste water by correlating data obtained by gas chromatography (GC) using atomic emission (AED) and mass selective (MS) detection. Solid-phase extraction (SPE) was coupled on-line to both GC

  16. Comprehensive two-dimensional liquid chromatography with on-line Fourier-transform-infrared-spectroscopy detection for the characterization of copolymers

    NARCIS (Netherlands)

    Kok, S.J.; Hankemeier, T.; Schoenmakers, P.J.

    2005-01-01

    The on-line coupling of comprehensive two-dimensional liquid chromatography (liquid chromatography × size-exclusion chromatography, LC × SEC) and infrared (IR) spectroscopy has been realized by means of an IR flow cell. The system has been assessed by the functional-group analysis of a series of

  17. Determination of anions with an on-line capillary electrophoresis method; Anionien on-line maeaeritys kapillaarielektroforeesilla - MPKT 10

    Energy Technology Data Exchange (ETDEWEB)

    Siren, H; Saerme, T; Kotiaho, T; Hiissa, T; Savolahti, P; Komppa, V [VTT Chemical Technology, Espoo (Finland)

    1999-12-31

    The aim of the study was to set-up an on-line capillary electrophoresis method for determination of anions in process waters of pulp and paper industry with exporting the results to the process control system of the mill. The quantification is important, since it will give information about the possible causes of precipitation. In recent years, the capillary electrophoresis (CE) due to its high separation efficiency has been shown as a method to take into consideration when analyzing chemical species ranging from small inorganic anions to different macromolecules. Many compounds are not easily detected in their native state, why analysis methods must be developed to improve their detection. Especially, small inorganic and organic anions which do not have chromophores are not sensitive enough for direct-UV detection. In such analyses the anions are mostly detected with indirect-UV technique. Capillary electrophoresis instruments are used to analyze samples in off-line, which seldom represent the situation in process. Therefore, on-line instrument technology with autoanalyzing settings will be needed in quality control. The development of a fully automatic capillary electrophoresis system is underway in co-operation with KCL (The Finnish Pulp and Paper Research Institute). In our research, we have first concentrated on the determination of sulphate in waters of paper industry. The method used for detection of sulphate is based on indirect-UV detection with CE, where the background electrolyte (BGE) is an absorbing mixture of secondary amines. The whole procedure for quantification of sulphate is performed within 15 minutes, after which a new sample is analyzed automatically. The only sample pretreatment is filtration, which is necessary before analysis. The concentrations of sulphate in process waters tested were between 300 and 800 ppm. Our tests show that a simultaneous determination of chloride, sulphate, nitrate, nitrite, sulphite, carbonate and oxalate is also

  18. Determination of anions with an on-line capillary electrophoresis method; Anionien on-line maeaeritys kapillaarielektroforeesilla - MPKT 10

    Energy Technology Data Exchange (ETDEWEB)

    Siren, H.; Saerme, T.; Kotiaho, T.; Hiissa, T.; Savolahti, P.; Komppa, V. [VTT Chemical Technology, Espoo (Finland)

    1998-12-31

    The aim of the study was to set-up an on-line capillary electrophoresis method for determination of anions in process waters of pulp and paper industry with exporting the results to the process control system of the mill. The quantification is important, since it will give information about the possible causes of precipitation. In recent years, the capillary electrophoresis (CE) due to its high separation efficiency has been shown as a method to take into consideration when analyzing chemical species ranging from small inorganic anions to different macromolecules. Many compounds are not easily detected in their native state, why analysis methods must be developed to improve their detection. Especially, small inorganic and organic anions which do not have chromophores are not sensitive enough for direct-UV detection. In such analyses the anions are mostly detected with indirect-UV technique. Capillary electrophoresis instruments are used to analyze samples in off-line, which seldom represent the situation in process. Therefore, on-line instrument technology with autoanalyzing settings will be needed in quality control. The development of a fully automatic capillary electrophoresis system is underway in co-operation with KCL (The Finnish Pulp and Paper Research Institute). In our research, we have first concentrated on the determination of sulphate in waters of paper industry. The method used for detection of sulphate is based on indirect-UV detection with CE, where the background electrolyte (BGE) is an absorbing mixture of secondary amines. The whole procedure for quantification of sulphate is performed within 15 minutes, after which a new sample is analyzed automatically. The only sample pretreatment is filtration, which is necessary before analysis. The concentrations of sulphate in process waters tested were between 300 and 800 ppm. Our tests show that a simultaneous determination of chloride, sulphate, nitrate, nitrite, sulphite, carbonate and oxalate is also

  19. On-line meters monitor gas concentrations in transformers

    Energy Technology Data Exchange (ETDEWEB)

    Pirhonen, R.; Lustre, L. [ed.

    1997-11-01

    Power transformers are by far the most expensive single components of 400 kV transmission grid substations. The acquisition price of a transformer is about FIM 15 to 20 million. A good way to extend the service life of a transformer considerably is to conduct a general overhaul. The cornerstone of cost-efficient maintenance is the correct timing of the general overhaul, which usually costs a couple million Finnish marks

  20. On-line milk spectrometry: analysis of bovine milk composition

    Science.gov (United States)

    Spitzer, Kyle; Kuennemeyer, Rainer; Woolford, Murray; Claycomb, Rod

    2005-04-01

    We present partial least squares (PLS) regressions to predict the composition of raw, unhomogenised milk using visible to near infrared spectroscopy. A total of 370 milk samples from individual quarters were collected and analysed on-line by two low cost spectrometers in the wavelength ranges 380-1100 nm and 900-1700 nm. Samples were collected from 22 Friesian, 17 Jersey, 2 Ayrshire and 3 Friesian-Jersey crossbred cows over a period of 7 consecutive days. Transmission spectra were recorded in an inline flowcell through a 0.5 mm thick milk sample. PLS models, where wavelength selection was performed using iterative PLS, were developed for fat, protein, lactose, and somatic cell content. The root mean square error of prediction (and correlation coefficient) for the nir and visible spectrometers respectively were 0.70%(0.93) and 0.91%(0.91) for fat, 0.65%(0.5) and 0.47%(0.79) for protein, 0.36%(0.49) and 0.45%(0.43) for lactose, and 0.50(0.54) and 0.48(0.51) for log10 somatic cells.

  1. On-line electrochemical monitoring of microbially influenced corrosion

    International Nuclear Information System (INIS)

    Dowling, N.J.E.; Stansbury, E.E.; White, D.C.; Borenstein, S.W.; Danko, J.C.

    1989-01-01

    Newly emerging electrochemical measurement techniques can provide on-line, non-destructive monitoring of the average corrosion rate and indications of localized pitting corrosion together with insight into fundamental electrochemical mechanisms responsible for the corrosion process. This information is relevant to evaluating, monitoring, understanding and controlling microbially influenced corrosion (MIC). MIC of coupons exposed in sidestream devices on site or in laboratory-based experiments, where the corrosion response is accelerated by exposure to active consortia of microbes recovered from specific sites, can be utilized to evaluate mitigation strategies. The average corrosion rates can be determined by small amplitude cyclic voltametry (SACV), and AC impedance spectroscopy (EIS). EIS can also give insight into the mechanisms of the MIC and indications of localized corrosion. Pitting corrosion can be detected non-destructively with open circuit potential monitoring (OCP). OCP also responds to bacterial biofilm activities such as oxygen depletion and other electrochemical activities. Utilizing these methods, accelerated tests can be designed to direct the selection of materials, surface treatments of materials, and welding filler materials, as well as the optimization of chemical and mechanical countermeasures with the microbial consortia recovered and characterized from the specific sites of interest

  2. On-line monitoring of low-level plutonium concentrations

    International Nuclear Information System (INIS)

    Hofstetter, K.J.; Huff, G.A.; Rebagay, T.V.

    1979-10-01

    An on-line monitor has been developed to assay plutonium in nitric acid solutions. The performance of the monitor has been assessed by a laboratory experimentation program using solutions with plutonium concentrations from 0.1 to 10 g/l. These conditions are typical of the plutonium solutions in an input stream to a plutonium-purification cycle in a reprocessing plant following uranium/plutonium partitioning. The monitoring system can be fully automated and shows great promise for detecting and quantifying plutonium in situ, thus minimizing the reliance on traditional sampling and laboratory-analysis techniques. The total concentration and isotopic abundance of plutonium are determined by measuring the absolute intensities of the low-energy gamma rays characteristics of 238 Pu, 239 Pu, and 240 Pu nuclides by direct gamma-ray spectroscopy and computer analysis of the spectral data. The addition of a monitoring system of this type to the input stream of a plutonium-purification cycle along with other suitable monitors on the waste streams and on the product stream provides the basis for a near real-time materials control and inventory system. Results of the laboratory-evaluation program employing plutonium in solutions with isotopic compositions typical of those involved in processing light water reactor fuels are presented. The detailed design of a monitoring cell and detection system is given. The precision and accuracy of the results relative to those measured by mass spectrometry and controlled potential coulometry are also summarized

  3. Virtual laboratories: Collaborative environments and facilities-on-line

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, C.E. Jr. [Oak Ridge National Lab., TN (United States). I and C Div.; Cavallini, J.S.; Seweryniak, G.R.; Kitchens, T.A.; Hitchcock, D.A.; Scott, M.A.; Welch, L.C. [Dept. of Energy, Germantown, MD (United States). Mathematical Information, and Computational Sciences Div.; Aiken, R.J. [Dept. of Energy, Germantown, MD (United States). Mathematical Information, and Computational Sciences Div.]|[Lawrence Livermore National Lab., CA (United States); Stevens, R.L. [Argonne National Lab., IL (United States). Mathematics and Computer Sciences Div.

    1995-07-01

    The Department of Energy (DOE) has major research laboratories in a number of locations in the US, typically co-located with large research instruments or research facilities valued at tens of millions to even billions of dollars. Present budget exigencies facing the entire nation are felt very deeply at DOE, just as elsewhere. Advances over the last few years in networking and computing technologies make virtual collaborative environments and conduct of experiments over the internetwork structure a possibility. The authors believe that development of these collaborative environments and facilities-on-line could lead to a ``virtual laboratory`` with tremendous potential for decreasing the costs of research and increasing the productivity of their capital investment in research facilities. The majority of these cost savings would be due to increased productivity of their research efforts, better utilization of resources and facilities, and avoiding duplication of expensive facilities. A vision of how this might all fit together and a discussion of the infrastructure necessary to enable these developments is presented.

  4. The Westinghouse BEACON on-line core monitoring system

    International Nuclear Information System (INIS)

    Buechel, Robert J.; Boyd, William A.; Casadei, Alberto L.

    1995-01-01

    BEACON (Best Estimate Analysis of Core Operations - Nuclear), a core monitoring and operational support package developed by Westinghouse, has been installed at many operating PWRs worldwide. The BEACON system is a real-time monitoring system which can be used in plants with both fixed and movable incore detector systems and utilizes an on-line nodal model combined with core instrumentation data to provide continuous core power distribution monitoring. In addition, accurate core-predictive capabilities utilizing a full core nodal model updated according to plant operating history can be made to provide operational support. Core history information is kept and displayed to help operators anticipate core behavior and take pro-active control actions. The BEACON system has been licensed by the U.S. Nuclear Regulatory Commission for direct, continuous monitoring of DNBR and peak linear heat rate. This allows BEACON to be integrated into the plant technical specifications to permit significant relaxation of operating limitations defined by conventional technical specifications. (author). 4 refs, 2 figs, 1 tab

  5. Development of an On-Line Uranium Enrichment Monitor

    International Nuclear Information System (INIS)

    Xuesheng, L.; Guorong, L.; Yonggang, Z.; Xueyuan, H. X.-Y.

    2015-01-01

    An on-line enrichment monitor was developed to measure the enrichment of UF6 flowing through the processing pipes in centrifuge uranium enrichment plant. A NaI(Tl) detector was used to measure the count rates of the 186 keV gamma ray emitted from 235U, and the total quantity of uranium was determined from thermodynamic characteristics of gaseous uranium hexafluoride. The results show that the maximum relative standard deviation is less than 1% when the measurement time is 120 s or more and the pressure is more than 2 kPa in the measurement chamber. There are two working models for the monitor. The monitor works normally in the continuous model, When the gas's pressure in the pipe fluctuates greatly, it can work in the intermittent model, and the measurement result is very well. The background of the monitor can be measured automatically periodically. It can control automatically electromagnetic valves open and close, so as to change the gas's quantity in the chamber. It is a kind of unattended and remote monitor, all of data can be transfer to central control room. It should be effective for nuclear materials accountability verifications and materials balance verification at uranium enrichment plant by using the monitor to monitor Uranium enrichment of gaseous uranium hexafluoride in the output end of cascade continuously. (author)

  6. On-line mass separator of superheavy atoms

    International Nuclear Information System (INIS)

    Oganesyan, Yu.Ts.

    2002-01-01

    The concept is presented of an on-line Mass Analyzer of SuperHeavy Atoms (MASHA) dedicated to the separation and determination of the mass and decay properties of new elements and isotopes produced in heavy-ion induced reactions. The new nuclides with half-lives T 1/2 ≥ 1 s are transported to an ECR-source working at a frequency of 2.45 GHz and are separated by mass with a mass resolution of M/ΔM ∼ 1500. In the focal plane of the magnetic analyzer a front strip detector surrounded by side detectors will be placed to determine the mass according to the signals from the detected α-particles or fission fragments with efficiency of about 90 %. In comparison to other existing in-flight recoil separators, the present setup will be characterized by higher efficiency and high selectivity relative to background reaction products. The setup MASHA may be used also in the investigation of nuclear reactions of different type induced by stable and radioactive beams

  7. On-Line Mass Separator of Superheavy Atoms

    CERN Document Server

    Oganessian, Yu T

    2002-01-01

    The concept is presented of an on-line Mass Analyzer of SuperHeavy Atoms (MASHA) dedicated to the separation and determination of the mass and decay properties of new elements and isotopes produced in heavy-ion induced reactions. The new nuclides with half-lives T_{1/2}\\ge 1 s are transported to an ECR-source working at a frequency of 2.45 GHz and are separated by mass with a mass resolution of M/\\Delta M\\sim 1500. In the focal plane of the magnetic analyzer a front strip detector surrounded by side detectors will be placed to determine the mass according to the signals from the detected alpha-particles or fission fragments with efficiency of about 90 %. In comparison to other existing in-flight recoil separators, the present setup will be characterized by higher efficiency and high selectivity relative to background reaction products. The setup MASHA may be used also in the investigation of nuclear reactions of different type induced by stable and radioactive beams.

  8. Optimization of an on-line function generation

    CERN Document Server

    Versteele, C

    1977-01-01

    A particular example of process control is the analog function generator of the CERN proton synchrotron. For magnet field correction, some magnets have to follow reference currents synchronous with the pulses of the synchrotron. Depending on the dynamic behaviour of the magnet system to be controlled, the output current will show a somewhat distorted image of the reference current used as input. An on-line computer strategy has been designed to compensate the distortions: i.e. to adjust the input function at successive pulses in such a way that the output current follows the reference as closely as required. However, the identification of such a system is not carried out because it is difficult and singular in any case. Modifications cannot be computed directly, but will result from an iterative strategy: the closed-loop adaptive control is based on a maximization procedure, requiring little memory and no gradient information. The algorithm is a variant of the optimization method called extended sequential se...

  9. On-line monitoring of methane in sewer air.

    Science.gov (United States)

    Liu, Yiwen; Sharma, Keshab R; Murthy, Sudhir; Johnson, Ian; Evans, Ted; Yuan, Zhiguo

    2014-10-16

    Methane is a highly potent greenhouse gas and contributes significantly to climate change. Recent studies have shown significant methane production in sewers. The studies conducted so far have relied on manual sampling followed by off-line laboratory-based chromatography analysis. These methods are labor-intensive when measuring methane emissions from a large number of sewers, and do not capture the dynamic variations in methane production. In this study, we investigated the suitability of infrared spectroscopy-based on-line methane sensors for measuring methane in humid and condensing sewer air. Two such sensors were comprehensively tested in the laboratory. Both sensors displayed high linearity (R(2) > 0.999), with a detection limit of 0.023% and 0.110% by volume, respectively. Both sensors were robust against ambient temperature variations in the range of 5 to 35°C. While one sensor was robust against humidity variations, the other was found to be significantly affected by humidity. However, the problem was solved by equipping the sensor with a heating unit to increase the sensor surface temperature to 35°C. Field studies at three sites confirmed the performance and accuracy of the sensors when applied to actual sewer conditions, and revealed substantial and highly dynamic methane concentrations in sewer air.

  10. Performing maintenance activities on-line a risk perspective

    International Nuclear Information System (INIS)

    Darling, S.S.; Mairs, T.P.

    1993-01-01

    The US nuclear power industry is attempting to deal with the issue of optimizing the performance of maintenance activities with the advent of the maintenance rule. The impact of any maintenance activity on the safe operation of a nuclear power facility can be quantified on the basis of risk. Therefore, it is incumbent upon the industry to accommodate the regulator and present a maintenance optimization program in terms that explicitly address the potential risk inherent in its concept and implementation. The motivation for utilities to perform maintenance while the plant is operating (i.e., on-line) is readily perceived to offer the following advantages: 1. greater system availability; 2. higher plant capacity factor; 3. more evenly distributed workload for the maintenance department; and 4. overall safer plant operation. However, risks inherent in undertaking maintenance activities during power operation could amount to the realization that reapportionment of these tasks is not cost-beneficial. Therefore, it is important that any utility considering implementing such a paradigm in maintenance philosophy establish a rigorous process to select, perform, and monitor maintenance tasks performed while operating

  11. On-line nuclear analysis of coal (Nucoalyzer)

    International Nuclear Information System (INIS)

    Brown, D.R.; Gozani, T.; Bozorgmanesh, H.

    1980-01-01

    Control of quality in the coal process stream is increasingly important in both coal preparation facilities and coal fire power plants. Traditional wet chemistry methods of monitoring coal composition are incapable of providing anything approaching real-time analysis of coal. Typically, small samples of the coal stream are laboratory analyzed and the results made available between a day to a week later. By this time the coal is through the process stream, often already burned and no control is possible. The need of real-time analysis of bulk quantities of the coal has long been recognized and this need motivated Science Applications, Inc. to develop, since 1975, a continuous on-line nuclear analyzer of coal (or CONAC). Over the last three years a prototype of this instrument has undergone extensive testing using 200 pound bulk samples of a wide variety of US coal types. The Nucoalyzer has proven capable of measuring the abundances of all the important elemental constituents of coal along with the ash and calorific value. In the past year the first instrument has been installed and undergone testing at Detroit Edison's Monroe Coal blending facility, where it will control the blending of high and low sulfur coal to meet EPA emission regulations

  12. An on-line tritium-in-water monitor

    International Nuclear Information System (INIS)

    Singh, A.N.; Ratnakaran, M.; Vohra, K.G.

    1985-01-01

    The paper describes the development and operation of a continuous on-line tritium-in-water monitor for the detection of heavy water leaks into the secondary coolant light water of a heavy water power reactor. The heart of the instrument is its plastic scintillator sponge detector, made from 5 μm thick plastic scintillator films. The sponge weighs only about 1 g and is in the form of disc of 48 mm diameter and 8 mm thickness. The total surface area of the films is about 3000 cm 2 . In the coincidence mode of counting, the detector gives 1000 cps for the passage of 3.7 x 10 4 Bq/cm 3 (1 μCi/cm 3 ) of tritiated water. The background in 6 cm thick lead shielding in the laboratory is 0.2 cps, and inside the reactor building it is below 1 cps. The monitor presently scans 18 sample lines in sequence for 5 min each and gives a printout for the activity in each line. (orig.)

  13. An on-line tritium-in-water monitor

    Science.gov (United States)

    Singh, A. N.; Ratnakaran, M.; Vohra, K. G.

    1985-05-01

    The paper describes the development and operation of a continuous on-line tritium-in-water monitor for the detection of heavy water leaks into the secondary coolant light water of a heavy water power reactor. The heart of the instrument is its plastic scintillator sponge detector, made from 5 μm thick plastic scintillator films. The sponge weighs only about 1 g and is in the form of disc of 48 mm diameter and 8 mm thickness. The total surface area of the films is about 3000 cm 2. In the coincidence mode of counting, the detector gives 1000 cps for the passage of 3.7 × 10 4 Bq/cm 3 (1 μCi/cm 3) of tritiated water. The background in 6 cm thick lead shielding in the laboratory is 0.2 cps, and inside the reactor building it is below 1 cps. The monitor presently scans 18 sample lines in sequence for 5 min each and gives a printout for the activity in each line.

  14. Knowledge-based on-line vibration monitoring diagnose

    International Nuclear Information System (INIS)

    Johansson, L.G.; Karlsson, A.; Noeremark, A.

    1990-01-01

    ABB STAL developed some years ago a knowledge-based on-line vibration analysis system (working-name KOVA). KOVA is intended to work together with some type of vibration monitoring system, at present it is adapted to TVM 300. KOVA has no controlling function. It will only diagnose the actual situation and give the user explanations and proposals for actions to be taken. During the developing work, great experience has been gained of the features this type of system demands. This paper will present the outlines of the application and also discuss how to make diagnoses based both on general rules as well as on historical vibration cases for that particular unit (or identical units9. Another subject that this paper will outline, is the representation and evaluation of knowledge. KOVA serves as a decision-support system for the operator. Since KOVA will often give the operator more than one possible diagnosis as the cause of a fault, it is of great importance to give the operator comprehensive explanations and as many facts as possible. It is also important to rank the suggested diagnoses in some way. In KOVA these demands are effectively supported. The models and tools used to realize this functionality will be described in this paper

  15. On-line monitoring of lithium carbonate dissolution

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Yuzhu; Song, Xingfu; Wang, Jin; Luo, Yan; Yu, Jianguo [National Engineering Research Center for Integrated Utilization Salt Lake Resources, East China University of Science and Technology, Shanghai (China)

    2009-11-15

    Dissolution of lithium carbonate (Li{sub 2}CO{sub 3}) in aqueous solution was investigated using three on-line apparatuses: the concentration of Li{sub 2}CO{sub 3} was measured by electrical conductivity equipment; CLD (Chord Length Distribution) was monitored by FBRM (Focused Beam Reflectance Measurement); crystal image was observed by PVM (Particle Video Microscope). Results show dissolution rate goes up with a decrease of particle size, and with an increase in temperature; stirring speed causes little impact on dissolution; ultrasound facilitates dissolution obviously. The CLD evolution and crystal images of Li{sub 2}CO{sub 3}powders in stirred fluid were observed detailedly by FBRM and PVM during dissolution. Experimental data were fitted to Avrami model, through which the activation energy was found to be 34.35 kJ/mol. PBE (Population Balance Equation) and moment transform were introduced to calculate dissolution kinetics, obtaining correlation equations of particle size decreasing rate as a function of temperature and undersaturation. (copyright 2009 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  16. Building collaboration tools and access to on-line facilities

    International Nuclear Information System (INIS)

    Agarwal, D.; Sachs, S.

    1996-11-01

    Network-based facilities will allow researchers at different locations to collaborate on experiments as if they all were together in the same laboratory. The expected value of these geographically distributed environments includes substantially increased effectiveness in doing science, and an enabling capability for analytical and high-value production use by industry. The Distributed, Collaboratory Experiment Environments (DCEE) Program consists of four projects that were established to build prototype remote experiment and collaborative environments. The work undertaken in this project represents some of the research and development of the mechanisms and infrastructure required to make collaboratories a reality. Some of these mechanisms have already been developed. Several other mechanisms, such as data dissemination, resource management for the sharing of experiment control, safety and security, electronic notebooks, elements of telepresence, and integrated user interfaces need further research and development. The pilot application for these collaborative tools is the Advanced Light Source (ALS) Beamline 7.0 at the Ernest Orlando Lawrence Berkeley Laboratory. The ALS is a particle accelerator and is a source of very high brilliance soft X-ray beams. One experimental facility is the Spectro-Microscopy Facility Beamline 7.0. Through this project, the Spectro-Microscopy Facility will be opened up to users from a wide range of organizations. The goal is to build software that will not only put the ALS Beamline 7.0 on-line, but will also serve as building blocks for future collaboratory development

  17. EXPANDING ACADEMIC VOCABULARY WITH AN INTERACTIVE ON-LINE DATABASE

    Directory of Open Access Journals (Sweden)

    Marlise Horst

    2005-05-01

    Full Text Available University students used a set of existing and purpose-built on-line tools for vocabulary learning in an experimental ESL course. The resources included concordance, dictionary, cloze-builder, hypertext, and a database with interactive self-quizzing feature (all freely available at www.lextutor.ca. The vocabulary targeted for learning consisted of (a Coxhead's (2000 Academic Word List, a list of items that occur frequently in university textbooks, and (b unfamiliar words students had met in academic texts and selected for entry into the class database. The suite of tools were designed to foster retention by engaging learners in deep processing, an aspect that is often described as missing in computer exercises for vocabulary learning. Database entries were examined to determine whether context sentences supported word meanings adequately and whether entered words reflected the unavailability of cognates in the various first languages of the participants. Pre- and post-treatment performance on tests of knowledge of words targeted for learning in the course were compared to establish learning gains. Regression analyses investigated connections between use of specific computer tools and gains.

  18. Design considerations for on-line vibration diagnostic systems

    International Nuclear Information System (INIS)

    Branagan, L.A.; Schjeibel, J.R.

    1989-01-01

    The decisions made in the design of a data system for on-line vibration diagnostic system in power plants define how well the system will meet its intended goals. Direct use of the data for performing troubleshooting or developing operating correlations requires an understanding of the subtle impact of the design decisions incorporated in the data system. A data system includes data acquisition, data storage, and data retrieval. Data acquisition includes the selection of sensors, of vibration measurement modes, and of the time stamping format, and the arrangement of data collection cycles. Data storage requires the evaluation of data compression options and of data segregation. Data retrieval design requires an understanding of the data storage and acquisition techniques. Each of these options and design decisions involves compromises, many of which are discussed in this paper. Actual and synthetic data are presented to illustrate these points. The authors' experience with multiple data collection cycles, with frequent monitoring, and with storage by exception suggests that these techniques can be developed into an effective diagnostic system

  19. Study of the on line radioactive multicharged ion production

    International Nuclear Information System (INIS)

    Lecesne, N.

    1997-01-01

    This work is directly related to the SPIRAL project (Systeme de Production d'Ions Radioactifs Acceleres en Ligne) which will start at GANIL at the end of 1998. The aim of the thesis was to study the on line radioactive multicharged ion beam production stages, i.e. the production and diffusion of the radioactive nuclei in a thick target, their possible transfer up to an ECR ion source and their ionisation. Production cross sections of radioactive neutron rich nuclei, formed by fragmentation of a heavy ion beam in a thick target, were measured. An external target-ECR source system, dedicated to the radioactive noble gases production, and two internal target-ECR source systems, dedicated to the radioactive condensable element production, were built and tested on the SIRa tests bench (Separateur d'Ions Radioactifs). Different detection configurations were elaborated in order to identify the radioactive nuclei and estimate their production yields. Finally, a new method for measuring the overall efficiency of the separator was developed and allowed to study the diffusion properties of radioactive noble gases in various targets. (author)

  20. On-line confidence monitoring during decision making.

    Science.gov (United States)

    Dotan, Dror; Meyniel, Florent; Dehaene, Stanislas

    2018-02-01

    Humans can readily assess their degree of confidence in their decisions. Two models of confidence computation have been proposed: post hoc computation using post-decision variables and heuristics, versus online computation using continuous assessment of evidence throughout the decision-making process. Here, we arbitrate between these theories by continuously monitoring finger movements during a manual sequential decision-making task. Analysis of finger kinematics indicated that subjects kept separate online records of evidence and confidence: finger deviation continuously reflected the ongoing accumulation of evidence, whereas finger speed continuously reflected the momentary degree of confidence. Furthermore, end-of-trial finger speed predicted the post-decisional subjective confidence rating. These data indicate that confidence is computed on-line, throughout the decision process. Speed-confidence correlations were previously interpreted as a post-decision heuristics, whereby slow decisions decrease subjective confidence, but our results suggest an adaptive mechanism that involves the opposite causality: by slowing down when unconfident, participants gain time to improve their decisions. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. 3081/E processor and its on-line use

    International Nuclear Information System (INIS)

    Rankin, P.; Bricaud, B.; Gravina, M.

    1985-05-01

    The 3081/E is a second generation emulator of a mainframe IBM. One of it's applications will be to form part of the data acquisition system of the upgraded Mark II detector for data taking at the SLAC linear collider. Since the processor does not have direct connections to I/O devices a FASTBUS interface will be provided to allow communication with both SLAC Scanner Processors (which are responsible for the accumulation of data at a crate level) and the experiment's VAX 8600 mainframe. The 3081/E's will supply a significant amount of on-line computing power to the experiment (a single 3081/E is equivalent to 4 to 5 VAX 11/780's). A major advantage of the 3081/E is that program development can be done on an IBM mainframe (such as the one used for off-line analysis) which gives the programmer access to a full range of debugging tools. The processor's performance can be continually monitored by comparison of the results obtained using it to those given when the same program is run on an IBM computer. 9 refs

  2. Gated Treatment Delivery Verification With On-Line Megavoltage Fluoroscopy

    International Nuclear Information System (INIS)

    Tai An; Christensen, James D.; Gore, Elizabeth; Khamene, Ali; Boettger, Thomas; Li, X. Allen

    2010-01-01

    Purpose: To develop and clinically demonstrate the use of on-line real-time megavoltage (MV) fluoroscopy for gated treatment delivery verification. Methods and Materials: Megavoltage fluoroscopy (MVF) image sequences were acquired using a flat panel equipped for MV cone-beam CT in synchrony with the respiratory signal obtained from the Anzai gating device. The MVF images can be obtained immediately before or during gated treatment delivery. A prototype software tool (named RTReg4D) was developed to register MVF images with phase-sequenced digitally reconstructed radiograph images generated from the treatment planning system based on four-dimensional CT. The image registration can be used to reposition the patient before or during treatment delivery. To demonstrate the reliability and clinical usefulness, the system was first tested using a thoracic phantom and then prospectively in actual patient treatments under an institutional review board-approved protocol. Results: The quality of the MVF images for lung tumors is adequate for image registration with phase-sequenced digitally reconstructed radiographs. The MVF was found to be useful for monitoring inter- and intrafractional variations of tumor positions. With the planning target volume contour displayed on the MVF images, the system can verify whether the moving target stays within the planning target volume margin during gated delivery. Conclusions: The use of MVF images was found to be clinically effective in detecting discrepancies in tumor location before and during respiration-gated treatment delivery. The tools and process developed can be useful for gated treatment delivery verification.

  3. Using Reading Guides and On-Line Quizzes to Improve Reading Compliance and Quiz Scores

    Science.gov (United States)

    Maurer, Trent W.; Longfield, Judith

    2015-01-01

    This study compared students' daily in-class reading quiz scores in an introductory Child Development course across five conditions: control, reading guide only, reading guide and on-line practice quiz, reading guide and on-line graded quiz, and reading guide and both types of on-line quizzes. At the beginning of class, students completed a 5-item…

  4. On-line Versus Face-to-Face Education: Utilizing Technology to Increase Effectiveness

    Science.gov (United States)

    2012-05-17

    Andragogy and learner-centered education provided in on-line education present excellent results. Secondly, the cost of on-line education compared to...13 Pedagogy versus Andragogy ...achieving learning outcomes. However, Andragogy and learner centered education provided in on-line education presents excellent results. Secondly, the cost

  5. On-line monitoring of solar cell module production by ellipsometry technique

    International Nuclear Information System (INIS)

    Fried, M.

    2014-01-01

    Non-destructive analyzing tools are needed at all stages of thin film photovoltaic (PV) development, and on production lines. In thin film PV, layer thicknesses, micro-structure, composition, layer optical properties, and their uniformity (because each elementary cell is connected electrically in series within a big panel) serve as an important starting point in the evaluation of the performance of the cell or module. An important focus is to express the dielectric functions of each component material in terms of a handful of wavelength independent parameters whose variation can cover all process variants of that material. With the resulting database, spectroscopic ellipsometry coupled with multilayer analysis can be developed for on-line point-by-point mapping and on-line line-by-line imaging. This work tries to review the investigations of different types of PV-layers (anti-reflective coating, transparent-conductive oxide (TCO), multi-diode-structure, absorber and window layers) showing the existing dielectric function databases for the thin film components of CdTe, CuInGaSe 2 , thin Si, and TCO layers. Off-line point-by-point mapping can be effective for characterization of non-uniformities in full scale PV panels in developing labs but it is slow in the on-line mode when only 15 points can be obtained (within 1 min) as a 120 cm long panel moves by the mapping station. In the last years [M. Fried et al., Thin Solid Films 519, 2730 (2011)], instrumentation was developed that provides a line image of spectroscopic ellipsometry (wl = 350–1000 nm) data. Up to now a single 30 point line image can be collected in 10 s over a 15 cm width of PV material. This year we are building a 30 and a 60 cm width expanded beam ellipsometer the speed of which will be increased by 10 ×. Then 1800 points can be mapped in a 1 min traverse of a 60 ∗ 120 cm PV panel or flexible roll-to-roll substrate. - Highlights: • Instrumentation developed provides a line image of

  6. On-line monitoring of solar cell module production by ellipsometry technique

    Energy Technology Data Exchange (ETDEWEB)

    Fried, M., E-mail: fried@mfa.kfki.hu

    2014-11-28

    Non-destructive analyzing tools are needed at all stages of thin film photovoltaic (PV) development, and on production lines. In thin film PV, layer thicknesses, micro-structure, composition, layer optical properties, and their uniformity (because each elementary cell is connected electrically in series within a big panel) serve as an important starting point in the evaluation of the performance of the cell or module. An important focus is to express the dielectric functions of each component material in terms of a handful of wavelength independent parameters whose variation can cover all process variants of that material. With the resulting database, spectroscopic ellipsometry coupled with multilayer analysis can be developed for on-line point-by-point mapping and on-line line-by-line imaging. This work tries to review the investigations of different types of PV-layers (anti-reflective coating, transparent-conductive oxide (TCO), multi-diode-structure, absorber and window layers) showing the existing dielectric function databases for the thin film components of CdTe, CuInGaSe{sub 2}, thin Si, and TCO layers. Off-line point-by-point mapping can be effective for characterization of non-uniformities in full scale PV panels in developing labs but it is slow in the on-line mode when only 15 points can be obtained (within 1 min) as a 120 cm long panel moves by the mapping station. In the last years [M. Fried et al., Thin Solid Films 519, 2730 (2011)], instrumentation was developed that provides a line image of spectroscopic ellipsometry (wl = 350–1000 nm) data. Up to now a single 30 point line image can be collected in 10 s over a 15 cm width of PV material. This year we are building a 30 and a 60 cm width expanded beam ellipsometer the speed of which will be increased by 10 ×. Then 1800 points can be mapped in a 1 min traverse of a 60 ∗ 120 cm PV panel or flexible roll-to-roll substrate. - Highlights: • Instrumentation developed provides a line image of

  7. Advanced mathematical on-line analysis in nuclear experiments. Usage of parallel computing CUDA routines in standard root analysis

    Science.gov (United States)

    Grzeszczuk, A.; Kowalski, S.

    2015-04-01

    Compute Unified Device Architecture (CUDA) is a parallel computing platform developed by Nvidia for increase speed of graphics by usage of parallel mode for processes calculation. The success of this solution has opened technology General-Purpose Graphic Processor Units (GPGPUs) for applications not coupled with graphics. The GPGPUs system can be applying as effective tool for reducing huge number of data for pulse shape analysis measures, by on-line recalculation or by very quick system of compression. The simplified structure of CUDA system and model of programming based on example Nvidia GForce GTX580 card are presented by our poster contribution in stand-alone version and as ROOT application.

  8. Influence Of Specific Mechanical Energy On Cornmeal Viscosity Measured By An On-line System During Twin-screw Extrusion

    OpenAIRE

    Chang Y.K.; Martinez-Bustos F.; Park T.S.; Kokini J.L.

    1999-01-01

    The influence of specific mechanical energy (SME) on cornmeal viscosity during the twin-screw extrusion at feed moisture contents of 25 and 30% and screw speeds in the range from 100 to 500 rpm was measured. Cornmeal was extruded in a co-rotating, intermeshing twin-screw coupled to a slit die rheometer. One approach to the on-line rheological measurement is to use a slit die with the extruder. In the present work it was show that shear viscosity decreased as a function of SME. The viscosity o...

  9. On-line Analysis of Catalytic Reaction Products Using a High-Pressure Tandem Micro-reactor GC/MS.

    Science.gov (United States)

    Watanabe, Atsushi; Kim, Young-Min; Hosaka, Akihiko; Watanabe, Chuichi; Teramae, Norio; Ohtani, Hajime; Kim, Seungdo; Park, Young-Kwon; Wang, Kaige; Freeman, Robert R

    2017-01-01

    When a GC/MS system is coupled with a pressurized reactor, the separation efficiency and the retention time are directly affected by the reactor pressure. To keep the GC column flow rate constant irrespective of the reaction pressure, a restrictor capillary tube and an open split interface are attached between the GC injection port and the head of a GC separation column. The capability of the attached modules is demonstrated for the on-line GC/MS analysis of catalytic reaction products of a bio-oil model sample (guaiacol), produced under a pressure of 1 to 3 MPa.

  10. The effect of family therapy on the changes in the severity of on-line game play and brain activity in adolescents with on-line game addiction

    Science.gov (United States)

    Han, Doug Hyun; Kim, Sun Mi; Lee, Young Sik; Renshaw, Perry F.

    2015-01-01

    We evaluated whether a brief 3-week family therapy intervention would change patterns of brain activation in response to affection and gaming cues in adolescents from dysfunctional families who met criteria for on-line game addiction. Fifteen adolescents with on-line game addiction and fifteen adolescents without problematic on-line game play and an intact family structure were recruited. Over 3 weeks, families were asked to carry out homework assignments focused on increasing family cohesion for more than 1 hour/day and 4 days/week. Before therapy, adolescents with on-line game addiction demonstrated decreased activity as measured by functional magnetic resonance imaging (fMRI) within the caudate, middle temporal gyrus, and occipital lobe in response to images depicting parental affection and increased activity of the middle frontal and inferior parietal in response scenes from on-line games, relative to healthy comparison subjects. Improvement in perceived family cohesion following 3 weeks of treatment was associated with an increase in the activity of the caudate nucleus in response to affection stimuli and was inversely correlated with changes in on-line game playing time. With evidence of brain activation changes in response to on-line game playing cues and images depicting parental love, the present findings suggest that family cohesion may be an important factor in the treatment of problematic on-line game playing. PMID:22698763

  11. In situ microscopy for on-line determination of biomass.

    Science.gov (United States)

    Bittner, C; Wehnert, G; Scheper, T

    1998-10-05

    A sensor is presented, which allows on-line microscopic observation of microorganisms during fermentations in bioreactors. This sensor, an In Situ Microscope (ISM) consists of a direct-light microscope with a measuring chamber, integrated in a 25 mm stainless steel tube, two CCD-cameras, and two frame-grabbers. The data obtained are processed by an automatic image analysis system. The ISM is connected with the bioreactor via a standard port, and it is immersed directly in the culture liquid-in our case Saccharomyces cerevisiae in a synthetic medium. The microscopic examination of the liquid is performed in the measuring chamber, which is situated near the front end of the sensor head. The measuring chamber is opened and closed periodically. In the open state, the liquid in the bioreactor flows unrestricted through the chamber. In closing, a defined volume of 2,2. 10(-8) mL of the liquid becomes enclosed. After a few seconds, when the movement of the cells in the enclosed culture has stopped, they are examined with the microscope. The microscopic images of the cells are registered with the CCD-cameras and are visualized on a monitor, allowing a direct view of the cell population. After detection, the measuring chamber reopens, and the enclosed liquid is released. The images obtained are evaluated as to cell concentration, cell size, cell volume, biomass, and other relevant parameters simultaneously by automatic image analysis. With a PC (486/33 MHz), image processing takes about 15 s per image. The detection range tested when measuring cells of S. cerevisiae is about 10(6) to 10(9) cells/mL (equivalent to a biomass of 0.01 g/L to 12 g/L). The calculated biomass values correlate very well with those obtained using dry weight analysis. Furthermore, histograms can be calculated, which are comparable to those obtained by flow cytometry. Copyright 1998 John Wiley & Sons, Inc.

  12. On-line sensor technology for food manufacturing industry. Shokuhin bun prime ya ni okeru on-line sensor gijutsu

    Energy Technology Data Exchange (ETDEWEB)

    Komiya, K. (Ajinomoto Co. Inc., Tokyo (Japan))

    1990-08-05

    This paper introduced the sensor technology for food manufacturing industry. If sugar concentration in main raw material is too high in the amino acid fermentation, control of the concentration is required because fungi growth is inhibited. A controlling method for sugar concentration was developed by using the correlation between consumption of NH {sub 3} for pH adjustment and sugar consumption in place of conventional analyzing method and was introduced in the gulutamic acid fermantation. BOD sensor was developed to enable the selective measurement of organic substances which can be processed by organisms, and measuring time was shortened from previous five days to 30 minutes. Since many organics absorb infrared ray, near infrared analysis is suitable for food analysis and on-line analysis has high possibility. When this method is applied to measure moisture in fishes and meats, continuous measurement can be made nondestructively and without contacting, and further the precision is {plus minus} 0.1%. Simultaneous multi-composition analyses are carried out by continuous spectrum and near infrared method using higher rate scanning. Sensor development for taste and smell has started. 10 refs., 4 figs., 4 refs.

  13. The internet and you getting on-line

    International Nuclear Information System (INIS)

    Anon.

    1995-01-01

    For anyone who hasn't seen a TV or newspaper in the last couple of years, the Internet is here. Those of us with even moderate exposure to the news have probably been flooded with hype, buzzwords, and references to the open-quotes Information Superhighway.close quotes But there's more than hype to the Internet, with inexpensive and almost instantaneous communication all over the world at your fingertips. This article is a summary of presently available Internet/Worldwide Web addresses for a numer of organizations, including: (1) US Department of Commerce, (2) US DOE, (3) US NRC, (4) Thomas, (5) CAPWEB, and (6) Fedworld

  14. On-line gas chromatographic analysis of airborne particles

    Science.gov (United States)

    Hering, Susanne V [Berkeley, CA; Goldstein, Allen H [Orinda, CA

    2012-01-03

    A method and apparatus for the in-situ, chemical analysis of an aerosol. The method may include the steps of: collecting an aerosol; thermally desorbing the aerosol into a carrier gas to provide desorbed aerosol material; transporting the desorbed aerosol material onto the head of a gas chromatography column; analyzing the aerosol material using a gas chromatograph, and quantizing the aerosol material as it evolves from the gas chromatography column. The apparatus includes a collection and thermal desorption cell, a gas chromatograph including a gas chromatography column, heated transport lines coupling the cell and the column; and a quantization detector for aerosol material evolving from the gas chromatography column.

  15. Pressurized capillary electrochromatographic analysis of water-soluble vitamins by combining with on-line concentration technique.

    Science.gov (United States)

    Jia, Li; Liu, Yaling; Du, Yanyan; Xing, Da

    2007-06-22

    A pressurized capillary electrochromatography (pCEC) system was developed for the separation of water-soluble vitamins, in which UV absorbance was used as the detection method and a monolithic silica-ODS column as the separation column. The parameters (type and content of organic solvent in the mobile phase, type and concentration of electrolyte, pH of the electrolyte buffer, applied voltage and flow rate) affecting the separation resolution were evaluated. The combination of two on-line concentration techniques, namely, solvent gradient zone sharpening effect and field-enhanced sample stacking, was utilized to improve detection sensitivity, which proved to be beneficial to enhance the detection sensitivity by enabling the injection of large volumes of samples. Coupling electrokinetic injection with the on-line concentration techniques was much more beneficial for the concentration of positively charged vitamins. Comparing with the conventional injection mode, the enhancement in the detection sensitivities of water-soluble vitamins using the on-line concentration technique is in the range of 3 to 35-fold. The developed pCEC method was applied to evaluate water-soluble vitamins in corns.

  16. Isotopic nuclear reactor with on-line separation

    International Nuclear Information System (INIS)

    Liviu, Popa-Simil

    2007-01-01

    In the new reactor-waste cycle design the nuclear reactor gets features of the living beings - resembling the plants/vegetation -. The separation of waste starts inside the fuel by using the fission reaction to separate the fission products from the fuel. The fuel, which is preferred to be highly isotopic enriched, is fabricated in beads smaller than the fission product range, immersed in a gentle flowing liquid drain. If this liquid is Lead Bismuth (LBE) the fission products will be lighter, while in Sodium-Potassium (NaK) will be heavier, except for gases. This drain liquid will collect both the fission products and the collision damage, drawing them slow to give time to short lives disintegration chains to take place inside the shielded nuclear reactor area outside the reactor core in a separation unit. While the drain liquid with the fission products is outside the reactor core few choices are available: - To solidify the drain liquid freezing all elements inside and transport the metal in cryogenic conditions to a remote separation unit, or to apply a separation partitioning process online stabilizing and packing the fission products only, or a combination of these two. The radioactivity of this drain liquid is smaller than that of the actual used fuel because it represents the accumulation of a very short period (about 1 month or less) and had enough time to cool down all the short lives. The separation unit on-line with the nuclear reactor is composed of a density separation unit, followed by a phase interface concentration unit which moves out of the LBE the fission products as lighter impurities, and an electrochemical separation unit for the fission products. Further, chemical separation, stabilization processes are applied and the fission products are delivered partitioned on groups of chemical compatible products. Finally the specific waste is about 1 Kg/Gw*day, to which the stabilization products have to be added which increases this mass by 10 times

  17. Monitoring of fission products through on-line gamma spectrometry

    International Nuclear Information System (INIS)

    Montagnon, F.; Warlop, R.

    1989-01-01

    Under normal operating conditions, the monitoring of the possible deterioration of the pressurized water reactor core fuel rods is achieved through analysis of the radioactive fission products carried by the primary system. For acquiring results of spectrometric analyses in real time, and avoiding risks of errors linked to manual operations, CEA/DMG and EDF/SEPTEN have jointly developed an entirely automatic system. This system allows measuring permanently the primary system activity of two coupled units, with no human operation nor any handling of active coolant specimens. The PIGAL facility has been set up in the nuclear auxiliary building, common to the two units, and it is used on a demonstration basis for units 2 and 3 of the BUGEY site. This device has been patented

  18. On-Line Detection of Coil Inter-Turn Short Circuit Faults in Dual-Redundancy Permanent Magnet Synchronous Motors

    Directory of Open Access Journals (Sweden)

    Yiguang Chen

    2018-03-01

    Full Text Available In the aerospace and military fields, with high reliability requirements, the dual-redundancy permanent magnet synchronous motor (DRPMSM with weak thermal coupling and no electromagnetic coupling is needed. A common fault in the DRPMSM is the inter-turn short circuit fault (ISCF. However, research on how to diagnose ISCF and the set of faulty windings in the DRPMSM is lacking. In this paper, the structure of the DRPMSM is analyzed and mathematical models of the motor under normal and faulty conditions are established. Then an on-line ISCF detection scheme, which depends on the running modes of the DRPMSM and the average values for the difference of the d-axis voltages between two sets of windings in the latest 20 sampling periods, is proposed. The main contributions of this paper are to analyze the calculation for the inductance of each part of the stator windings and propose the on-line diagnosis method of the ISCF under various operating conditions. The simulation and experimental results show that the proposed method can quickly and effectively diagnose ISCF and determine the set of faulty windings of the DRPMSM.

  19. On-line analysis of algae in water by discrete three-dimensional fluorescence spectroscopy.

    Science.gov (United States)

    Zhao, Nanjing; Zhang, Xiaoling; Yin, Gaofang; Yang, Ruifang; Hu, Li; Chen, Shuang; Liu, Jianguo; Liu, Wenqing

    2018-03-19

    In view of the problem of the on-line measurement of algae classification, a method of algae classification and concentration determination based on the discrete three-dimensional fluorescence spectra was studied in this work. The discrete three-dimensional fluorescence spectra of twelve common species of algae belonging to five categories were analyzed, the discrete three-dimensional standard spectra of five categories were built, and the recognition, classification and concentration prediction of algae categories were realized by the discrete three-dimensional fluorescence spectra coupled with non-negative weighted least squares linear regression analysis. The results show that similarities between discrete three-dimensional standard spectra of different categories were reduced and the accuracies of recognition, classification and concentration prediction of the algae categories were significantly improved. By comparing with that of the chlorophyll a fluorescence excitation spectra method, the recognition accuracy rate in pure samples by discrete three-dimensional fluorescence spectra is improved 1.38%, and the recovery rate and classification accuracy in pure diatom samples 34.1% and 46.8%, respectively; the recognition accuracy rate of mixed samples by discrete-three dimensional fluorescence spectra is enhanced by 26.1%, the recovery rate of mixed samples with Chlorophyta 37.8%, and the classification accuracy of mixed samples with diatoms 54.6%.

  20. Field Trial of LANL On-Line Advanced Enrichment Monitor for UF6 GCEP

    Energy Technology Data Exchange (ETDEWEB)

    Ianakiev, Kiril D. [Los Alamos National Laboratory; Lombardi, Marcie [Los Alamos National Laboratory; MacArthur, Duncan W. [Los Alamos National Laboratory; Parker, Robert F. [Los Alamos National Laboratory; Smith, Morag K. [Los Alamos National Laboratory; Keller, Clifford [Los Alamos National Laboratory; Friend, Peter [URENCO; Dunford, Andrew [URENCO

    2012-07-13

    The outline of this presentation is: (1) Technology basis of on-line enrichment monitoring; (2) Timescale of trial; (3) Description of installed equipment; (4) Photographs; (5) Results; (6) Possible further development; and (7) Conclusions. Summary of the good things about the Advanced Enrichment Monitor (AEM) performance is: (1) High accuracy - normally better than 1% relative, (2) Active system as accurate as passive system, (3) Fast and accurate detection of enrichment changes, (4) Physics is well understood, (5) Elegant method for capturing pressure signal, and (6) Data capture is automatic, low cost and fast. A couple of negative things are: (1) Some jumps in measured passive enrichment - of around +2% relative (due to clock errors?); and (2) Data handling and evaluation is off-line, expensive and very slow. Conclusions are: (1) LANL AEM is being tested on E23 plant at Capenhurst; (2) The trial is going very well; (3) AEM could detect production of HEU at potentially much lower cost than existing CEMO; (4) AEM can measure {sup 235}U assay accurately; (5) Active system using X-Ray source would avoid need for pressure measurement; (6) Substantial work lies ahead to go from current prototype to a production instrument.

  1. Atomic emission spectroscopy for the on-line monitoring of incineration processes

    International Nuclear Information System (INIS)

    Timmermans, E.A.H.; Groote, F.P.J. de; Jonkers, J.; Gamero, A.; Sola, A.; Mullen, J.J.A.M. van der

    2003-01-01

    A diagnostic measurement system based on atomic emission spectroscopy has been developed for the purpose of on-line monitoring of hazardous elements in industrial combustion gases. The aim was to construct a setup with a high durability for rough and variable experimental conditions, e.g. a strongly fluctuating gas composition, a high gas temperature and the presence of fly ash and corrosive effluents. Since the setup is primarily intended for the analysis of combustion gases with extremely high concentrations of pollutants, not much effort has been made to achieve low detection limits. It was found that an inductively coupled argon plasma was too sensitive to molecular gas introduction. Therefore, a microwave induced plasma torch, compromising both the demands of a high durability and an effective evaporation and excitation of the analyte was used as excitation source. The analysis system has been installed at an industrial hazardous waste incinerator and successfully tested on combustion gases present above the incineration process. Abundant elements as zinc, lead and sodium could be easily monitored

  2. Turbidimetric Measurement for On-line Monitoring of SiO2 Particles

    International Nuclear Information System (INIS)

    Kim, In Sook; Lim, H. B.; Kim, Yang Sun

    2004-01-01

    In this work, the fundamental study of on-line monitoring of SiO 2 particles in the size range of 40 nm to 725 nm was carried out using turbidimetry. The size of particle was measured using a field emission scanning electron microscope (FE-SEM). The factors affecting on the turbidity were discussed, for example, wavelength, size, and concentration. In order to observe the dependence of turbidity on the wavelength, a turbidimetric system equipped with charged coupled detector (CCD) was built. The shape of the transmitted peak was changed and the peak maximum was shifted to the red when the concentration of particle was increased. This result indicates that the turbidity is related to the wavelength, which corresponds to the characteristic of the Mie extinction coefficient, Q, that is a function of not only particle diameter and refractive index but also wavelength. It is clear that a linear calibration curve for each particle in different size can be obtained at an optimized wavelength

  3. Rapid assessment of mycotoxins in wine by on-line SPE-UHPLC-FLD

    Directory of Open Access Journals (Sweden)

    Nistor Alina-Mihaela

    2017-01-01

    Full Text Available According to the latest statistics, grapes are one of the largest fruit crops worldwide. In this regard, it is important to consider all factors influencing quality of grapes and wine. In the last years, scientist focused on the study of mycotoxins that can influence the quality of wine. It is considered that toxins produced by moulds, causing significant economic losses, affect approximately one quarter of the world grape production. If the selective sorting of infected grapes is not done adequately, wine will present a major risk to consumers, mycotoxins being considered by the “International Agency for Cancer Research” a carcinogenic compound. The main mycotoxins monitored in this study come from Aspergillus sp., and are represented by aflatoxins B1, B2, G1, G2 and ochratoxin A. This study purpose is to develop a faster method for the analysis of mycotoxins, in order to increase rapidity and efficiency for the evaluation of the degree of infestation in wine. The purposed method is using an on-line large volume injection coupled to pre-concentration of sample (SPE which is directly transfer to the ultra-high-pressure liquid chromatography (UHPLC column for separation and the detection by means of the fluorescence detector (FLD. As the maximum tolerated level for mycotoxins in wines is 2 ppm, this method is able to detect under this limits of quantification with RSD below 2%.

  4. Perceptions Towards On-line Banking Security: An Empirical Investigation of a Developing Country`s Banking Sector, how secure is On-line Banking

    OpenAIRE

    Bongani Ngwenya; Khanyisa Malufu

    2012-01-01

    The increase in computer crime has led to scepticism about themove made by the banks to introduce on-line banking. Someview this as a noble move which has made the banking systemmore efficient, reliable and secure, while others view it as arisky and insecure way of banking. The aim of this study wasto assess whether on-line banking in the developing countriesis secure or not. The researcher chose a descriptive-quantitativeresearch design. Data was collected using a self constructedquestionnai...

  5. BOOK REVIEW: ON-LINE EDUCATION: AN EMANCIPATING VISION

    Directory of Open Access Journals (Sweden)

    Reviewed by Dr. Abdullah KUZU

    2006-04-01

    Full Text Available ON-LINE EDUCATION: AN EMANCIPATING VISION Written by Margarita Victoria Gomez Publisher: Cortez Editora ISBN 85-249-1062-3 São Paulo, Brazil, July 2004. Reviewed by Ricardo Romo TORRES Manuel Moreno Castaneda Maria del Sol Orozco Aguirre Universidad de Guadalajara Virtual MEXICO http://www.udgvirtual.udg.mx "On-line Education " is a book that meets the challenge to present itself as an unfinished text. In addition to demanding an active participation of the reader, it requires a predisposition to complete it through an also inconclusive dialogue. Among its goals we can find the search for education networks that remain under constant reconstruction, maintaining the emancipative vision as an imperative for the reconfiguration, as a constituted tissue for the scaffolding of subjects who impress,imagine, think and have a will. The unfinished part is presented in the following paragraph: "Similar to Babel according to Borges, knowledge is the product of a hazard in which fiction is the universe and where, out of fear of its multiple combinations, individual texts constitute an unfinished tale. In this labyrinth-shaped universe, the mirror and the recurrence do not allow finding the way out" page 134. The sense of being of man within a planetary community is framed by the ontological condition of conclusiveness; the requirement of being more, however, as well. This more is guided by the need for dialogue with others in terms of the opening and maintaining an unconcluded dialogue. The idea of a web or network leads to an articulating demand within the context of the category of wholeness. Based on this category, we will be able to present a reticulum of concepts where we can find included the web, subjectivity, identity, experience, mediation and, of course, digital literacy. This reticulum results in a concept of identified education with a condensed arrival point to something that the author defines as 'the pedagogy of virtuality'. The author is

  6. On-line determination of anions in pulp mills by capillary electrophoresis (CE); Tehdasoloissa tapahtuva anionien kapillaarielektroforeettinen on-line maeaeritys ja sen hyoedyntaeminen prosessivalvonnassa - MPKY 02

    Energy Technology Data Exchange (ETDEWEB)

    Kokkonen, R; Holmberg, M; Vainikka, V [Finnish Pulp and Paper Research Institute, Espoo (Finland)

    1999-12-31

    The aim of the study was to set-up a process control system for on-line measurement of certain anions. Typical anions which forms precipitates in pulp and paper mills are oxalate, carbonate and sulphate. Thus it is important to develop a continuous process analyzing system to control concentration levels of this anions. For the preliminary tests of continuous determinations of chloride and sulphate anions in tap water a simple on-line system was build in KCL (The Finnish Pulp and Paper Research Institute) and connected to a capillary electroforesis apparatus. In the preliminary tests a chromate buffer (ph = 7.6) was used. Separation of chloride and sulphate was excellent but the stability of buffer was not good enough and it was usable only for few hours. After experimental studies VTT developed a stable capillary electrophoresis method based on mixed amine buffer and this was selected for an on-line method for determination of anions in process waters of the pulp and paper industry. In the preliminary on-line test (r = 20) repeatabilities of migration times of sulphate and chloride with the chromate buffer were < 5 % (RSD) and peak heights < 15 % (RSD). With the mixed amine buffer repeatabilities were better. The preliminary tests showed that it is possible to connect a capillary electrophoresis system to on-line measurements. For the moment no commercial on-line CE apparatus is available. (orig.)

  7. On-line determination of anions in pulp mills by capillary electrophoresis (CE); Tehdasoloissa tapahtuva anionien kapillaarielektroforeettinen on-line maeaeritys ja sen hyoedyntaeminen prosessivalvonnassa - MPKY 02

    Energy Technology Data Exchange (ETDEWEB)

    Kokkonen, R.; Holmberg, M.; Vainikka, V. [Finnish Pulp and Paper Research Institute, Espoo (Finland)

    1998-12-31

    The aim of the study was to set-up a process control system for on-line measurement of certain anions. Typical anions which forms precipitates in pulp and paper mills are oxalate, carbonate and sulphate. Thus it is important to develop a continuous process analyzing system to control concentration levels of this anions. For the preliminary tests of continuous determinations of chloride and sulphate anions in tap water a simple on-line system was build in KCL (The Finnish Pulp and Paper Research Institute) and connected to a capillary electroforesis apparatus. In the preliminary tests a chromate buffer (ph = 7.6) was used. Separation of chloride and sulphate was excellent but the stability of buffer was not good enough and it was usable only for few hours. After experimental studies VTT developed a stable capillary electrophoresis method based on mixed amine buffer and this was selected for an on-line method for determination of anions in process waters of the pulp and paper industry. In the preliminary on-line test (r = 20) repeatabilities of migration times of sulphate and chloride with the chromate buffer were < 5 % (RSD) and peak heights < 15 % (RSD). With the mixed amine buffer repeatabilities were better. The preliminary tests showed that it is possible to connect a capillary electrophoresis system to on-line measurements. For the moment no commercial on-line CE apparatus is available. (orig.)

  8. Comparing On-Line to In-Person Course Delivery: An Empirical Study

    OpenAIRE

    Jammie Price; Leslie Hossfeld

    2007-01-01

    Web-based technologies have been used in the classroom for over 15 years, including websites, email, listserves, library reserves, and text books. Among these options, social scientists range widely in their web usage – from simply posting syllabi on-line to delivering a course fully on-line in asynchronous learning networks. Use of web-based technology for instructional purposes is increasing, as is enrollment in distance education courses and on-line course offerings. Many administrators ...

  9. On-Line Booking Policies and Competitive Analysis of Medical Examination in Hospital

    Directory of Open Access Journals (Sweden)

    Li Luo

    2014-01-01

    Full Text Available From the on-line point, we consider the hospital’s medical examination appointment problem with hierarchical machines. This approach eliminates the need for both demand forecasts and a risk-neutrality assumption. Due to different unit revenue, uncertain demand, and arrival of patients, we design on-line booking policies for two kinds of different situations from the perspective of on-line policy and competitive analysis. After that, we prove the optimal competitive ratios. Through numerical examples, we compare advantages and disadvantages between on-line policies and traditional policies, finding that there is different superiority for these two policies under different arrival sequences.

  10. Application of a mechanistic model as a tool for on-line monitoring of pilot scale filamentous fungal fermentation processes-The importance of evaporation effects.

    Science.gov (United States)

    Mears, Lisa; Stocks, Stuart M; Albaek, Mads O; Sin, Gürkan; Gernaey, Krist V

    2017-03-01

    A mechanistic model-based soft sensor is developed and validated for 550L filamentous fungus fermentations operated at Novozymes A/S. The soft sensor is comprised of a parameter estimation block based on a stoichiometric balance, coupled to a dynamic process model. The on-line parameter estimation block models the changing rates of formation of product, biomass, and water, and the rate of consumption of feed using standard, available on-line measurements. This parameter estimation block, is coupled to a mechanistic process model, which solves the current states of biomass, product, substrate, dissolved oxygen and mass, as well as other process parameters including k L a, viscosity and partial pressure of CO 2 . State estimation at this scale requires a robust mass model including evaporation, which is a factor not often considered at smaller scales of operation. The model is developed using a historical data set of 11 batches from the fermentation pilot plant (550L) at Novozymes A/S. The model is then implemented on-line in 550L fermentation processes operated at Novozymes A/S in order to validate the state estimator model on 14 new batches utilizing a new strain. The product concentration in the validation batches was predicted with an average root mean sum of squared error (RMSSE) of 16.6%. In addition, calculation of the Janus coefficient for the validation batches shows a suitably calibrated model. The robustness of the model prediction is assessed with respect to the accuracy of the input data. Parameter estimation uncertainty is also carried out. The application of this on-line state estimator allows for on-line monitoring of pilot scale batches, including real-time estimates of multiple parameters which are not able to be monitored on-line. With successful application of a soft sensor at this scale, this allows for improved process monitoring, as well as opening up further possibilities for on-line control algorithms, utilizing these on-line model outputs

  11. Application status of on-line nuclear techniques in analysis of coal quality

    International Nuclear Information System (INIS)

    Cai Shaohui

    1993-01-01

    Nuclear techniques are favourable for continuous on-line analysis, because they are fast, non-intrusive. They can be used in the adverse circumstances in coal industry. The paper reviews the application status of on-line nuclear techniques in analysis of coal quality and economic benefits derived from such techniques in developed countries

  12. On-line monitoring and control of animal-cell cultures

    NARCIS (Netherlands)

    Pol, van der J.J.

    1996-01-01


    On-line analysis and control of biotechnological processes is still the stepchild in industry. In general, only parameters as dissolved-oxygen concentration, pH and temperature are controlled on-line. Important parameters as substrate and inhibitor concentrations are only measured

  13. On-line scheduling of two-machine open shops where jobs arrive over time

    NARCIS (Netherlands)

    Chen, B.; Vestjens, A.P.A.; Woeginger, G.J.

    1998-01-01

    We investigate the problem of on-line scheduling two-machine open shops with the objective of minimizing the makespan.Jobs arrive independently over time, and the existence of a job is not known until its arrival. In the clairvoyant on-line model, the processing requirement of every job becomes

  14. College Students' Choice Modeling of Taking On-Line International Business Courses

    Science.gov (United States)

    Yeh, Robert S.

    2006-01-01

    To understand students' choice behavior of taking on-line international business courses, a survey study is conducted to collect information regarding students' actual choices of taking on-line courses and potential factors that may have impacts on students' choices of online learning. Potential factors such as enrollment status, demographic…

  15. State of technology, system and solution supporting on-line maintenance - company's activities and products

    International Nuclear Information System (INIS)

    Nishitani, Junichi; Shimizu, Shunichi; Higasa, Hisakazu

    2010-01-01

    The new inspection system based on operator's maintenance and monitoring program of nuclear power plants was introduced in Japan more than one year ago and recommended on-line maintenance (maintenance during operation) will be carried out to increase capacity factor with safe and reliable operation of the plant. In this feature article, nine experts described the state of technology, system and solution supporting on-line maintenance - company's activities and products. These were titled as 'MHI's technology supporting on-line maintenance'. 'Technology supporting on-line maintenance - Toshiba's activities to upgrade monitoring and diagnostic service and maintenance management', 'AsahiKASEI's activities of on-line maintenance', 'Importance of information sharing of on-line maintenance and its ideal method-function of impact plan of IBM Maximo Asset Management for Nuclear', 'US's on-line maintenance and information systems', 'SmartProcedures realizing safe operation of nuclear power plant - proposal of computerized procedures', 'Ultrasonic leak detection system SDT170', 'Application of infrared thermography for equipment maintenance in nuclear power plant' and 'On-line condition monitoring system - condition eye'. (T. Tanaka)

  16. 75 FR 57826 - Culturally Significant Objects Imported for Exhibition Determinations: “On Line: Drawing Through...

    Science.gov (United States)

    2010-09-22

    ... DEPARTMENT OF STATE [Public Notice 7180] Culturally Significant Objects Imported for Exhibition Determinations: ``On Line: Drawing Through the Twentieth Century'' SUMMARY: Notice is hereby given of the... that the objects to be included in the exhibition ``On Line: Drawing Through the Twentieth Century...

  17. Challenges and opportunities in ‘last mile’ logistics for on-line food retail

    NARCIS (Netherlands)

    Trienekens, Jacques; Hvolby, Hans Henrik; Turner, Paul

    2017-01-01

    Conventional approaches to logistics for food retail continue to be challenged by the rapid growth of on-line food retail. At the same time, ‘last mile’ logistics optimization for on-line retail also face challenges as changing consumer expectations, habits and purchasing patterns intersect with

  18. Multi-Mode Operation for On-line Uninterruptible Power Supply System

    DEFF Research Database (Denmark)

    Lu, Jinghang; Savaghebi, Mehdi; Golestan, Saeed

    2018-01-01

    To enhance the robustness and disturbance rejection ability of an on-line uninterruptible power supply (UPS) system, an Internal Model Control (IMC)-based DC-link voltage regulation method is proposed in this paper. Furthermore, the multi-mode operations of the on-line UPS system are investigated...

  19. Analyze On-line Star Economy Basing on Models of Entrepreneurship

    Institute of Scientific and Technical Information of China (English)

    胡志豪

    2016-01-01

    The outstanding performance of the On-line Star Economy is bound up with social media and promotion by fans, stimulating a new round of consumption upgrading and capital tendency. There is no denying that the On-line Star Economy may be the fortuitous outcome of the times. But the fact remains it can be analyzed rationally using Models of Entrepreneurship.

  20. Escapist Motives for On-line Gaming and Strengthening of Weak Ties

    DEFF Research Database (Denmark)

    Sudzina, Frantisek; Razmerita, Liana

    on-line gaming. The research investigates Facebook and other on-line games separate-ly. A surprising result is that while most of the investigated escapist motives are positively correlated with strengthening of weak ties, the mundane breaking motive is negatively correlated with strengthening...

  1. A New Method of On-line Grid Impedance Estimation for PV Inverter

    DEFF Research Database (Denmark)

    Teodorescu, Remus; Asiminoaei, Lucian; Blaabjerg, Frede

    2004-01-01

    for on-line measuring the grid impedance is presented. The presented method requires no extra hardware being accommodated by typical PV inverters, sensors and CPU, to provide a fast and low cost approach of on-line impedance measurement. By injecting a non-characteristic harmonic current and measuring...

  2. Semi-on-line analysis for fast and precise monitoring of bioreaction processes

    DEFF Research Database (Denmark)

    Christensen, L.H.; Marcher, J.; Schulze, Ulrik

    1996-01-01

    Monitoring of substrates and products during fermentation processes can be achieved either by on-line, in situ sensors or by semi-on-line analysis consisting of an automatic sampling step followed by an ex situ analysis of the retrieved sample. The potential risk of introducing time delays...

  3. Supercritical fluid extraction (SFE) of ketamine metabolites from dried urine and on-line quantification by supercritical fluid chromatography and single mass detection (on-line SFE-SFC-MS).

    Science.gov (United States)

    Hofstetter, Robert; Fassauer, Georg M; Link, Andreas

    2018-02-15

    On-line solid-phase supercritical fluid extraction (SFE) and chromatography (SFC) coupled to mass spectrometry (MS) has been evaluated for its usefulness with respect to metabolic profiling and pharmacological investigations of ketamine in humans. The aim of this study was to develop and validate a rapid, highly selective and sensitive SFE-SFC-MS method for the quantification of ketamine and its metabolites in miniature amounts in human urine excluding liquid-liquid extraction (LLE). Several conditions were optimized systematically following the requirements of the European Medicines Agency: selectivity, carry-over, calibration curve parameters (LLOQ, range and linearity), within- and between-run accuracy and precision, dilution integrity, matrix effect, and stability. The method, which required a relatively small volume of human urine (20 μL per sample), was validated for pharmacologically and toxicologically relevant concentrations ranging from 25.0 to 1000 ng/mL (r 2  > 0.995). The lower limit of quantification (LLOQ) for all compounds was found to be as low as 0.5 ng. In addition, stability of analytes during removal of water from the urine samples using different conditions (filter paper or ISOLUTE® HM-N) was studied. In conclusion, the method developed in this study can be successfully applied to studies of ketamine metabolites in humans, and may pave the way for routine application of on-line SFE-SFC-MS in clinical investigations. Copyright © 2018 Elsevier B.V. All rights reserved.

  4. Penjualan on-line berbasis media sosial dalam perspektif ekonomi Islam

    Directory of Open Access Journals (Sweden)

    M. Nur Riyanto Al-Arif

    2013-06-01

    Full Text Available Contemporary transactions along with the development of existing technologies have given rise to other forms of trading i.e. on-line trading. This paper aims to look at how the Islamic economic perspectives associated with on-line trading. The method used in this paper was library research. On-line trading had fulfilled the shariah principle, i.e. al-aqid, s}i>ghah, al-ma’qu>d alaih and the goal of the transaction. The transaction models that can be adopt in trading on line are bay’ al-mura>bah}ah and bay’ al-sala>m. Trading online had several advantage for buyer and seller, but trading on-line also had several problems. So, we must to had a strategy to minimize the various problems that may arise.

  5. FEDIX on-line information service: Design, develop, test, and implement an on-line research and education information service. Annual status report, September 1992--August 1993

    Energy Technology Data Exchange (ETDEWEB)

    Rodman, J.A.

    1993-08-01

    Federal Information Exchange, Inc. (FIE) is a diversified information services company that is recognized as the major electronic link between the higher education community and the Federal government in the field of research administration. FIE provides a range of information related services to the government, academic and private sectors, including database management, software development and technical support. FEDIX is the on-line information service designed, developed and implemented by FIE to accomplish the following objectives: (1). Broaden the participation of the education community in Federal research and education programs by providing free and unrestricted on-line access to information from all participating Federal agencies; and (2). Provide the education community with on-line access to a single keyword-searchable system for research and educational funding opportunities at the participating Federal agencies.

  6. Risk-informed decision-making related to the on-line maintenance

    International Nuclear Information System (INIS)

    Cepin, Marko

    2011-01-01

    On-line maintenance (OLM) represents the term, which includes testing and maintenance that is performed when the main generator of the nuclear power plant is connected to the grid. OLM on one side helps to decrease the number of activities, which would be performed during the scheduled outage, but on the other side it may contribute to a different level of risk, if the activity is performed when the plant is operating. If the risk of OLM during the power operation is much larger than the risk of similar activity performed during the shutdown the OLM may not be the desired strategy. Additionally, if the risk of OLM during the power operation is not larger than the risk of similar activity performed during the shutdown, the OLM would be the preferred strategy. The objective of the paper is to show risk evaluations of selected OLM activities of selected real plants and to examine if the current practices are suitable for the new nuclear power plants. The results of risk evaluations of OLM and their comparison show that the criteria or guidelines developed for existing plants are not completely suitable for new plants. The new power plants with expected lower risk measures, which can be lower for more than couple of orders of magnitude compared to existing plants, would be able to deal with OLM in plant configurations which would increase the risk for orders of magnitude, but would still be acceptable in terms of risk, if the existing criteria or guidelines are used. Results suggest that the risk guidelines for the OLM should be updated for their use in the case of new nuclear power plants.

  7. A study on non-contact ultrasonic technique for on-line inspection of CFRP

    International Nuclear Information System (INIS)

    Lee, Seung-Joon; Park, Won-Su; Lee, Joon-Hyun; Byun, Joon-Hyung

    2007-01-01

    The advantages of carbon fiber reinforced plastic materials (CFRP) are: they are light structure materials, they have corrosion resistance, and higher specific strength and elasticity. The recently developed 3-dimentional fiber placement system is able to produce a more complex and various shaped structures due to less limitations of a product shape according to the problem in conventional fabrication process. This fiber placement system stacks the narrow prepreg tape on the mold according to the designed sequence and thickness. Non-destructive evaluation was rquired for these composites to evaluate changes in strength caused by defects such as delamination and porosity. Additionally, the expectent quality should be satisfied for the high cost fabrication process using the fiber placement system. Therefore, an on line non-destructive evaluation system is required and real-time complement is needed when the defects are detected [1]. Defect imaging by the ultrasonic C-scan method is a useful technique for defect detection in CFRP. However, the conventional ultrasonic C-scan technique cannot be applied during the fabrication process because the test piece should be immersed into the water. Therefore, non-contact ultrasonic techniques should be applied during the fabricating process. For the development of non-contact ultrasonic techniques available in non-destructive evaluation of CFRP, a recent laser-generated ultrasonic technique and an air-coupled transducer that transmit and receive ultrasounds in the air are studied [2-3]. In this study, generating and receiving techniques of laser-generated ultrasound and the characteristics of received signals upon the internal defects of CFRO were studied for non-contact inspection

  8. On-line removal of volatile fatty acids from CELSS anaerobic bioreactor via nanofiltration.

    Science.gov (United States)

    Colon, G; Sager, J C

    2001-01-01

    The CELSS resource recovery system, which is a waste-processing system, uses aerobic and anaerobic bioreactors to recover plants nutrients and secondary foods from the inedible biomass. The anaerobic degradation of the inedible biomass, by means of culture of rumen bacteria, generates organic compounds such as volatile fatty acids (VFA) (acetic, propionic, butyric) and ammonia. The presence of VFA in the bioreactor medium at fairly low concentrations decreases the microbial population's metabolic reactions due to end-product inhibition. Technologies to remove VFA continuously from the bioreactor are of high interest. Several candidate technologies were analyzed, such as organic solvent liquid-liquid extraction, adsorption and/or ion exchange, dialysis, electrodialysis, and pressure-driven membrane separation processes. The proposed technique for the on-line removal of VFA from the anaerobic bioreactor was a nanofiltration membrane recycle bioreactor. In order to establish the nanofiltration process performance variables before coupling it to the bioreactor, a series of experiments was carried out using a 10,000 molecular weight cutoff (MWCO) tubular ceramic membrane module. The variables studied were the bioreactor slurry permeation characteristics, such as: the permeate flux, VFA and nutrient removal rates as a function of applied transmembrane pressure, fluid recirculation velocity, suspended matter concentration, and process operating time. Results indicated that the permeate flux, VFA, and nutrients removal rates are directly proportional to the fluid recirculation velocity in the range between 0.6 and 1.0 m/s, applied pressure when these are lower than 1.5 bar, and inversely proportional to the total suspended solids concentration in the range between 23,466 and 34,880 mg/L. At applied pressure higher than 1.5 bar the flux is not more linearly dependent due to concentration polarization and fouling effects over the membrane surface. It was also found that the

  9. On-line removal of volatile fatty acids from CELSS anaerobic bioreactor via nanofiltration

    Science.gov (United States)

    Colon, Guillermo

    1995-01-01

    The CELSS (controlled ecological life support system) resource recovery system, which is a waste processing system, uses aerobic and anaerobic bioreactors to recover plants nutrients and secondary foods from the inedible biomass. The anaerobic degradation of the inedible biomass by means of culture of rumen bacteria,generates organic compounds such as volatile fatty acids (acetic, propionic, butyric, VFA) and ammonia. The presence of VFA in the bioreactor medium at fairly low concentrations decreases the microbial population's metabolic reactions due to end-product inhibition. Technologies to remove VFA continuously from the bioreactor are of high interest. Several candidate technologies were analyzed, such as organic solvent liquid-liquid extraction, adsorption and/or ion exchange, dialysis, electrodialysis, and pressure driven membrane separation processes. The proposed technique for the on-line removal of VFA from the anaerobic bioreactor was a nanofiltration membrane recycle bioreactor. In order to establish the nanofiltration process performance variables before coupling it to the bioreactor, a series of experiments were carried out using a 10,000 MWCO tubular ceramic membrane module. The variables studied were the bioreactor slurry permeation characteristics, such as, the permeate flux, VFA and the nutrient removal rates as a function of applied transmembrane pressure, fluid recirculation velocity, suspended matter concentration, and process operating time. Results indicate that the permeate flux, VFA and nutrients removal rates are directly proportional to the fluid recirculation velocity in the range between 0.6 to 1.0 m/s, applied pressure when these are low than 1.5 bar, and inversely proportional to the total suspended solids concentration in the range between 23,466 to 34,880. At applied pressure higher than 1.5 bar the flux is not more linearly dependent due to concentration polarization and fouling effects over the membrange surface. It was also found

  10. Entrepreneurial Couples

    DEFF Research Database (Denmark)

    Dahl, Michael S.; Van Praag, Mirjam; Thompson, Peter

    2015-01-01

    We study possible motivations for co-entreprenurial couples to start up a joint firm, using a sample of 1,069 Danish couples that established a joint enterprise between 2001 and 2010. We compare their pre-entry characteristics, firm performance and post-dissolution private and financial outcomes...

  11. TARMS, an on-line boiling water reactor operation management system. [3 D core simulator LOGOS 2

    Energy Technology Data Exchange (ETDEWEB)

    Iwamoto, T.; Sakurai, S.; Uematsu, H.; Tsuiki, M.; Makino, K.

    1984-12-01

    The TARMS (Toshiba Advanced Reactor Management System) software package was developed as an effective on-line, on-site tool for boiling water reactor core operation management. It was designed to support a complete function set to meet the requirement to the current on-line process computers. The functions can be divided into two categories. One is monitoring of the present core power distribution as well as related limiting parameters. The other is aiding site engineers or reactor operators in making the future reactor operating plan. TARMS performs these functions with a three-dimensional BWR core physics simulator LOGOS 2, which is based on modified one-group, coarse-mesh nodal diffusion theory. A method was developed to obtain highly accurate nodal powers by coupling LOGOS 2 calculations with the readings of an in-core neutron flux monitor. A sort of automated machine-learning method also was developed to minimize the errors caused by insufficiency of the physics model adopted in LOGOS 2. In addition to these fundamental calculational methods, a number of core operation planning aid packages were developed and installed in TARMS, which were designed to make the operator's inputs simple and easy.

  12. Tandem on-line continuous separations for atomic spectroscopic indirect analysis: iodide determination by ICP-AES

    International Nuclear Information System (INIS)

    Garcia, A.M.; Sanchez Uria, J.E.; Sanz-Medel, A.; Quintero Ortega, M.C.; Bautista, J.C.

    1992-01-01

    A sensitive and selective indirect determination of iodide by inductively coupled plasma emission spectrometry (ICP-AES) based on the principle of tandem on-line continuous separations as an alternative means of introducing samples into plasmas is proposed. Iodide is continuously extracted as an ion-pair into xylene by mixing the sample with Hg(II) and dipyridil solutions. The organic phase (containing the analyte in [Hg(Dipy) 2 ]I 2 form) is on-line continuously mixed with NaBH 4 (in DMF) and acetic acid solutions. Mercury vapour continuously generated from this organic phase is separated in a classical U-type gas-liquid separation device. The system has been optimized for the continuous extraction of KI, for the direct generation of cold mercury vapour from xylene and for the final ICP-AES determination of mercury. The optimised method has been applied to the determination of iodide (detection limit 20 ng/ml of iodide) in table salt and in synthetic samples. Very good agreement between found and certified results was observed. The usefulness and convenience of such alternative sample chemical pretreatment/presentation to the ICP is thus demonstrated for indirect determinations to be carried out by atomic spectroscopy methods. (authors)

  13. El aprendizaje on-line: oportunidades y retos en instituciones politécnicas Apprenticeship Students Learning On-line: Opportunities and Challenges for Polytechnic Institutions

    Directory of Open Access Journals (Sweden)

    Martha Burkle

    2011-10-01

    Full Text Available Este artículo presenta los retos y las oportunidades actuales respecto a la distribución de contenidos virtuales y online en el marco de la institución de educación superior politécnica. Debido a la recesión económica actual, se está produciendo un retorno de estudiantes aprendices al mundo académico con el fin de actualizar habilidades y conocimientos. Sin embargo, a menudo los estudiantes con este perfil no están dispuestos a dejar de lado el trabajo o su vida personal para volver al estudio. En este contexto, el aprendizaje on-line representa una magnífica oportunidad para acceder a contenidos académicos sin tener que dejar de lado el trabajo. No obstante, para garantizar el éxito en la provisión de materiales on-line para estudiantes aprendices, las instituciones politécnicas de todo el mundo deben enfrentar dos retos: la transformación de contenidos de aprendizaje práctico en objetos educativos en línea, y la creación de ambientes educativos en los que los estudiantes se sientan involucrados y participativos. Más aún, en un ambiente de aprendizaje en el que el uso de tecnologías Web 2.0 es primordial, es importante considerar también el nuevo rol del profesor, que se ha convertido en facilitador del aprendizaje. Con el fin de analizar la experiencia educativa on-line de estos estudiantes, se distribuyeron 57 encuestas entre los estudiantes registrados en programas de formación on-line. El artículo presenta las conclusiones de la investigación y las compara con las aportaciones que se han hecho en lo relativo a la nueva generación de estudiantes y su uso de las tecnologías, así como el comportamiento registrado por la muestra de la investigación (preferencias y estilos de aprendizaje, su uso de las nuevas tecnologías. Se plantean igualmente oportunidades innovadoras para conectar aprendizaje y contexto laboral y recomendaciones para futuras investigaciones.This paper presents the ongoing research on the

  14. Advanced mathematical on-line analysis in nuclear experiments. Usage of parallel computing CUDA routines in standard root analysis

    Directory of Open Access Journals (Sweden)

    Grzeszczuk A.

    2015-01-01

    Full Text Available Compute Unified Device Architecture (CUDA is a parallel computing platform developed by Nvidia for increase speed of graphics by usage of parallel mode for processes calculation. The success of this solution has opened technology General-Purpose Graphic Processor Units (GPGPUs for applications not coupled with graphics. The GPGPUs system can be applying as effective tool for reducing huge number of data for pulse shape analysis measures, by on-line recalculation or by very quick system of compression. The simplified structure of CUDA system and model of programming based on example Nvidia GForce GTX580 card are presented by our poster contribution in stand-alone version and as ROOT application.

  15. Exploiting Sequential Injection on-line Solvent Extraction/Back Extraction with Detection by ETAAS or ICPMS

    DEFF Research Database (Denmark)

    Wang, Jianhua; Hansen, Elo Harald

    presents an on-line SI-solvent extraction/back extraction procedure used in connection with detection by either ETAAS or ICPMS. Incorporating two newly designed dual-conical gravitational phase separators, its performance is demonstrated for the determination of various metals in reference materials.......Electrothermal atomic absorption spectrometry (ETAAS) and inductively coupled plasma mass spectrometry (ICPMS) are highly sensitive techniques for trace metal analyses. Nevertheless, separation/preconcentration procedures are often called for in order to overcome their inherent low matrix...... tolerances. With detection by ETAAS, separation/preconcentration by solvent extraction has enjoyed much use. However, this approach is not necessarily the optimal one since introduction of organic eluates directly into the graphite tube might lead to deteriorated reproducibility and lower sensitivity...

  16. Exploiting sequential injection on-line solvent extraction/back extraction with detection by ETAAS and ICPMS

    DEFF Research Database (Denmark)

    Wang, Jianhua; Hansen, Elo Harald

    presents an on-line SI-solvent extraction/back extraction procedure used in connection with detection by either ETAAS or ICPMS. Incorporating two newly designed dual-conical gravitational phase separators, its performance is demonstrated for the determination of various metals in reference materials.......Electrothermal atomic absorption spectrometry (ETAAS) and inductively coupled plasma mass spectrometry (ICPMS) are highly sensitive techniques for trace metal analyses. Nevertheless, separation/preconcentration procedures are often called for in order to overcome their inherent low matrix tolerance....... With detection by ETAAS, separation/preconcentration by solvent extraction has enjoyed much use. However, this approach is not necessarily the optimal one since introduction of organic eluates directly into the graphite tube might lead to deteriorated reproducibility and lower sensitivity. And for ICPMS...

  17. Rapid dereplication of estrogenic compounds in pomegranate (Punica granatum) using on-line biochemical detection coupled to mass spectrometry

    NARCIS (Netherlands)

    van Elswijk, D.A.; Schobel, U.; Lansky, EP; Irth, H.; de Greef, J

    2004-01-01

    During recent years, phytoestrogens have been receiving an increasing amount of interest, as several lines of evidence suggest a possible role in preventing a range of diseases, including the hormonally dependent cancers. In this context, various parts of the pomegranate fruit (Punica granatum;

  18. Multidrug analysis of pharmaceutical and urine matrices by on-line coupled capillary electrophoresis and triple quadrupole mass spectrometry.

    Science.gov (United States)

    Maráková, Katarína; Piešt'anský, Juraj; Veizerová, Lucia; Galba, Jaroslav; Dokupilová, Svetlana; Havránek, Emil; Mikuš, Peter

    2013-06-01

    The present work illustrates potentialities of CE hyphenated with MS/MS for the simultaneous determination and identification of a mixture of simultaneously acting drugs in pharmaceutical and biological matrices. Here, the hyphenation was provided by ESI interface, while the MS/MS technique was based on the triple quadrupole configuration. Three drugs, namely pheniramine, phenylephrine, and paracetamol were determined and identified with high reliability due to their characterization in three different dimensions, i.e. electrophoresis and MS/MS, that prevented practically any interference. Appropriately selected transitions of the analytes (parent ion-quantifier product ion-qualifier product ion) provided their selective determination at maximum S/N. The proposed CE-MS/MS method was validated (LOD/LOQ, linearity, precision, recovery, accuracy) and applied for (i) the multidrug composition pharmaceuticals, namely Theraflu®, and (ii) human urine taken after per-oral administration of the same pharmaceutical preparation. The method was applied also for the investigation of potential weak associates of the drugs and monitoring of predicted (bio)degradation products of the drugs. Successful validation and application of the proposed method suggest its routine use in highly effective and reliable advanced drug control and biomedical research. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Comparing On-Line to In-Person Course Delivery: An Empirical Study

    Directory of Open Access Journals (Sweden)

    Jammie Price

    2007-05-01

    Full Text Available Web-based technologies have been used in the classroom for over 15 years, including websites, email, listserves, library reserves, and text books. Among these options, social scientists range widely in their web usage – from simply posting syllabi on-line to delivering a course fully on-line in asynchronous learning networks. Use of web-based technology for instructional purposes is increasing, as is enrollment in distance education courses and on-line course offerings. Many administrators and faculty promote on-line instruction as the solution to managing increased college enrollments, particularly among non-traditional students. However, are the academic outcomes of on-line instruction similar to traditional in-person instruction? Few empirical studies have been done. This is unfortunate. The results of an experiment to evaluate the relative effectiveness of on-line verses an in-person course on sociological research are presented. Unfortunately the on-line participants did much worse than the in-person course.

  20. On-line monitoring applications at nuclear power plants. A risk informed approach to calibration reduction

    International Nuclear Information System (INIS)

    Shankar, Ramesh; Hussey, Aaron; Davis, Eddie

    2003-01-01

    On-line monitoring of instrument channels provides increased information about the condition of monitored channels through accurate, more frequent evaluation of each cannel's performance over time. This type of performance monitoring is a methodology that offers an alternate approach to traditional time-directed calibration. EPRI's strategic role in on-line monitoring is to facilitate its implementation and cost-effective use in numerous applications at power plants. To this end, EPRI has sponsored an on-line monitoring implementation project at multiple nuclear plants specifically intended to install and use on-line monitoring technology. The selected on-line monitoring method is based on the Multivariate State Estimation Technique. The project has a planned three-year life; seven plants are participating in the project. The goal is to apply on-line monitoring to all types of power plant applications and document all aspects of the implementation process in a series of EPRI reports. These deliverables cover installation, modeling, optimization, and proven cost-benefit. This paper discusses the actual implementation of on-line monitoring to various nuclear plant instrument systems. Examples of detected instrument drift are provided. (author)

  1. Continuous monitoring of bisulfide variation in microdialysis effluents by on-line droplet-based microfluidic fluorescent sensor.

    Science.gov (United States)

    Zhu, Xiaocui; Xu, Lei; Wu, Tongbo; Xu, Anqin; Zhao, Meiping; Liu, Shaorong

    2014-05-15

    We demonstrate a novel fluorescent sensor for real-time and continuous monitoring of the variation of bisulfide in microdialysis effluents by using a nanoparticle-glutathione-fluorescein isothiocyanate (AuNP-GSH-FITC) probe coupled with on-line droplet-based microfluidic chip. The AuNP-GSH-FITC fluorescent probe was firstly developed and used for bisulfide detection in bulk solution by quantitative real-time PCR, which achieved a linear working range from 0.1 μM to 5.0 μM and a limit of detection of ~50 nM. The response time was less than 2 min. With the aid of co-immobilized thiol-polyethylene glycol, the probe exhibited excellent stability and reproducibility in high salinity solutions, including artificial cerebrospinal fluids (aCSF). By adding 0.1% glyoxal to the probe solution, the assay allowed quantification of bisulfide in the presence of cysteine at the micro-molarity level. Using the AuNP-GSH-FITC probe, a droplet-based microfluidic fluorescent sensor was further constructed for online monitoring of bisulfide variation in the effluent of microdialysis. By using fluorescence microscope-charge-coupled device camera as the detector, the integrated microdialysis/microfluidic chip device achieved a detection limit of 2.0 μM and a linear response from 5.0 μM to 50 μM for bisulfide in the tested sample. The method was successfully applied for the on-line measurement of bisulfide variation in aCSF and serum samples. It will be a very useful tool for tracking the variation of bisulfide or hydrogen sulfide in extracellular fluids. Copyright © 2013 Elsevier B.V. All rights reserved.

  2. On-line reputation systems : the effects of feedback comments and reactions on building and rebuilding trust in on-line auctions

    NARCIS (Netherlands)

    Utz, S.; Matzat, U.; Snijders, C.C.P.

    2009-01-01

    Previous research on reputation systems primarily focused on their trust-building function. The present research addresses their trust-rebuilding function-specifically, the role of the short text comments given in reaction to negative feedback. Rebuilding trust is often necessary because on-line

  3. Development of an on-line mixed-mode gel liquid chromatography×reversed phase liquid chromatography method for separation of water extract from Flos Carthami.

    Science.gov (United States)

    Wang, Yu-Qing; Tang, Xu; Li, Jia-Fu; Wu, Yun-Long; Sun, Yu-Ying; Fang, Mei-Juan; Wu, Zhen; Wang, Xiu-Min; Qiu, Ying-Kun

    2017-10-13

    A novel on-line comprehensive two-dimensional liquid chromatography (2D-LC) method by coupling mixed-mode gel liquid chromatography (MMG-LC) with reversed phase liquid chromatography (RPLC) was developed. A mixture of 17 reference compounds was used to study the separation mechanism. A crude water extract of Flos Carthami was applied to evaluate the performance of the novel 2D-LC system. In the first dimension, the extract was eluted with a gradient of water/methanol over a cross-linked dextran gel Sephadex LH-20 column. Meanwhile, the advantages of size exclusion, reversed phase partition and adsorption separation mechanism were exploited before further on-line reversed phase purification on the second dimension. This novel on-line mixed-mode Sephadex LH-20×RPLC method provided higher peak resolution, sample processing ability (2.5mg) and better orthogonality (72.9%) versus RPLC×RPLC and hydrophilic interaction liquid chromatography (HILIC)×RPLC. To the best of our knowledge, this is the first report of a mixed-mode Sephadex LH-20×RPLC separation method with successful applications in on-line mode, which might be beneficial for harvesting targets from complicated medicinal plants. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Lessons Learned by Comparing On-line Education Strategies Across Disciplines

    Directory of Open Access Journals (Sweden)

    Stephen H. Edwards

    2004-12-01

    Full Text Available When choosing how best to employ educational technologies for on-line learning, there is much to be gained by examining the experience of educators in other disciplines. This paper presents four brief case studies in the disciplines of computer science and social work. Lessons learned by comparing these diverse experiences are discussed, including creating a community of learners, supporting asynchronous student communication, using synchronous on-line meetings, and providing social support. In addition, the experiences presented indicate that stereotypes of student capabilities and expectations may often be inaccurate, and revising one's views may be helpful in achieving better results in on-line education.

  5. Development and Implementation of an Electric Circuits On-Line Course

    Directory of Open Access Journals (Sweden)

    Ahmed Hussain

    2009-02-01

    Full Text Available An electric circuit on-line course has been developed at KFUPM to support student centered learning. The course has been used in the first stage to supplement the class room face-to-face instruction. This paper describes the development stages of the on-line course and highlights its fundamental features that are not available in the traditional methods of instruction. The paper also includes the results of a survey conducted among students who have utilized the on-line material to supplement their traditional study of the electric circuits’ course. The results of the survey showed a general satisfaction with the course content and the instructional effectiveness.

  6. On-line data analysis and monitoring for H1 drift chambers

    Science.gov (United States)

    Düllmann, Dirk

    1992-05-01

    The on-line monitoring, slow control and calibration of the H1 central jet chamber uses a VME multiprocessor system to perform the analysis and a connected Macintosh computer as graphical interface to the operator on shift. Task of this system are: - analysis of event data including on-line track search, - on-line calibration from normal events and testpulse events, - control of the high voltage and monitoring of settings and currents, - monitoring of temperature, pressure and mixture of the chambergas. A program package is described which controls the dataflow between data aquisition, differnt VME CPUs and Macintosh. It allows to run off-line style programs for the different tasks.

  7. On-line preconcentration of fluorescent derivatives of catecholamines in cerebrospinal fluid using flow-gated capillary electrophoresis.

    Science.gov (United States)

    Zhang, Qiyang; Gong, Maojun

    2016-06-10

    Flow-gated capillary electrophoresis (CE) coupled with microdialysis has become an important tool for in vivo bioanalytical measurements because it is capable of performing rapid and efficient separations of complex biological mixtures thus enabling high temporal resolution in chemical monitoring. However, the limit of detection (LOD) is often limited to a micro- or nano-molar range while many important target analytes have picomolar or sub-nanomolar levels in brain and other tissues. To enhance the capability of flow-gated CE for catecholamine detection, a novel and simple on-line sample preconcentration method was developed exclusively for fluorescent derivatives of catecholamines that were fluorogenically derivatized with naphthalene-2,3-dicarboxaldehyde (NDA) in the presence of cyanide. The effective preconcentration coupled with the sensitive laser-induced fluorescence (LIF) detection lowered the LOD down to 20pM for norepinephrine (NE) and 50pM for dopamine (DA) at 3-fold of S/N ratio, and the signal enhancement was estimated to be over 100-fold relative to normal injection when standard analytes were dissolved in artificial cerebrospinal fluid (aCSF). The basic focusing principle is novel since the sample plug contains borate while the background electrolyte (BGE) is void of borate. This strategy took advantage of the complexation between diols and borate, through which one negative charge was added to the complex entity. The sample derivatization mixture was electrokinetically injected into a capillary via the flow-gated injection, and then NE and DA derivatives were selectively focused to a narrow zone by the reversible complexation. Separation of NE and DA derivatives was executed by incoming surfactants of cholate and deoxycholate mixed in the front BGE plug. This on-line preconcentration method was finally applied to the detection of DA in rat cerebrospinal fluid (CSF) via microdialysis and on-line derivatization. It is anticipated that the method would

  8. Entrepreneurial Couples

    DEFF Research Database (Denmark)

    Dahl, Michael S.; Van Praag, Mirjam; Thompson, Peter

    with a selected set of comparable firms and couples. We find evidence that couples often establish a business together because one spouse – most commonly the female – has limited outside opportunities in the labor market. However, the financial benefits for each of the spouses, and especially the female......We study possible motivations for co-entrepenurial couples to start up a joint firm, using a sample of 1,069 Danish couples that established a joint enterprise between 2001 and 2010. We compare their pre-entry characteristics, firm performance and postdissolution private and financial outcomes......, are larger in co-entrepreneurial firms, both during the life of the business and post-dissolution. The start-up of co-entrepreneurial firms seems therefore a sound investment in the human capital of both spouses as well as in the reduction of income inequality in the household. We find no evidence of non...

  9. Entrepreneurial Couples

    DEFF Research Database (Denmark)

    Dahl, Michael S.; Van Praag, Mirjam; Thompson, Peter

    with a selected set of comparable firms and couples. We find evidence that couples often establish a business together because one spouse - most commonly the female - has limited outside opportunities in the labor market. However, the financial benefits for each of the spouses, and especially the female......We study possible motivations for co-entrepenurial couples to start up a joint firm, us-ing a sample of 1,069 Danish couples that established a joint enterprise between 2001 and 2010. We compare their pre-entry characteristics, firm performance and post-dissolution private and financial outcomes......, are larger in co-entrepreneurial firms, both during the life of the business and post-dissolution. The start-up of co-entrepreneurial firms seems therefore a sound in-vestment in the human capital of both spouses as well as in the reduction of income inequality in the household. We find no evidence of non...

  10. On-Line Digital Computer Applications in Gas Chromatography, An Undergraduate Analytical Experiment

    Science.gov (United States)

    Perone, S. P.; Eagleston, J. F.

    1971-01-01

    Presented are some descriptive background materials and the directions for an experiment which provides an introduction to on-line computer instrumentation. Assumes students are familiar with the Purdue Real-Time Basic (PRTB) laboratory computer system. (PR)

  11. First on-line $\\beta$-NMR on oriented nuclei magnetic dipole moments of the $\

    CERN Document Server

    Giles, T; Stone, N J; Van Esbroeck, K; White, G; Wöhr, A; Veskovic, M; Towner, I S; Mantica, P F; Prisciandaro, J I; Morrissey, D J; Fedosseev, V; Mishin, V I; Köster, U; Walters, W B

    2000-01-01

    The first fully on-line use of the angular distribution of $\\beta$ - emission in detection of NMR of nuclei oriented at low temperatures is reported. The magnetic moments of the single valence particle, intermediate mass, isotopes $^{67}$Ni($\

  12. Research progress of on-line automatic monitoring of chemical oxygen demand (COD) of water

    Science.gov (United States)

    Cai, Youfa; Fu, Xing; Gao, Xiaolu; Li, Lianyin

    2018-02-01

    With the increasingly stricter control of pollutant emission in China, the on-line automatic monitoring of water quality is particularly urgent. The chemical oxygen demand (COD) is a comprehensive index to measure the contamination caused by organic matters, and thus it is taken as one important index of energy-saving and emission reduction in China’s “Twelve-Five” program. So far, the COD on-line automatic monitoring instrument has played an important role in the field of sewage monitoring. This paper reviews the existing methods to achieve on-line automatic monitoring of COD, and on the basis, points out the future trend of the COD on-line automatic monitoring instruments.

  13. Multiparametric amplitude analysis with on-line compression using adaptive orthogonal transform

    Energy Technology Data Exchange (ETDEWEB)

    Morhac, M; Matousek, V; Turzo, I

    1996-12-31

    The new method of multiparameter amplitude analysis with on-line compression is developed. The proposed method decreases the memory needed to store multidimensional histograms. Examples of employing the algorithms for three-dimensional spectra are presented. 5 refs.

  14. On-Line Trajectory Retargeting for Alternate Landing Sites, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Barron Associates, Inc. proposes to develop a novel on-line trajectory optimization approach for Reusable Launch Vehicles (RLVs) under failure scenarios, targeting...

  15. The current role of on-line extraction approaches in clinical and forensic toxicology.

    Science.gov (United States)

    Mueller, Daniel M

    2014-08-01

    In today's clinical and forensic toxicological laboratories, automation is of interest because of its ability to optimize processes, to reduce manual workload and handling errors and to minimize exposition to potentially infectious samples. Extraction is usually the most time-consuming step; therefore, automation of this step is reasonable. Currently, from the field of clinical and forensic toxicology, methods using the following on-line extraction techniques have been published: on-line solid-phase extraction, turbulent flow chromatography, solid-phase microextraction, microextraction by packed sorbent, single-drop microextraction and on-line desorption of dried blood spots. Most of these published methods are either single-analyte or multicomponent procedures; methods intended for systematic toxicological analysis are relatively scarce. However, the use of on-line extraction will certainly increase in the near future.

  16. CODE STEM - Moon, Mars, and Beyond; DLESE-Powered On-Line Classroom, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — "CODE (COrps DEvelopment) STEM (Science, Technology, Engineering, and Math) ? Moon Mars and Beyond; DLESE-Powered On-Line Classroom" shares the excitement of...

  17. On-line data processing apparatus for spectroscopic measurements of atomic uranium

    International Nuclear Information System (INIS)

    Miron, E.; Levin, L.A.; Erez, G; Baumatz, D; Goren, I.; Shpancer, I.

    1977-01-01

    A computer-based apparatus for on-line spectroscopic measurements of atomic uranium is described. The system is capable of enhancing the signal-to-noise ratio by averaging, and performing calculations. Computation flow charts and programs are included

  18. Integrated electrochemical sensor array for on-line monitoring of yeast fermentations

    NARCIS (Netherlands)

    Krommenhoek, E.E.; Gardeniers, Johannes G.E.; Bomer, Johan G.; Li, X.; Ottens, M.; van Dedem, G.W.K.; van Leeuwen, M.; van Gulik, W.M.; van der Wielen, L.A.M.; Heijnen, J.J.; van den Berg, Albert

    2007-01-01

    This paper describes the design, modeling, and experimental characterization of an electrochemical sensor array for on-line monitoring of fermentor conditions in both miniaturized cell assays and in industrial scale fertnentations. The viable biomass concentration is determined from impedance

  19. On-line Vibration Diagnostics of the Optical Elements at BL-28 of the Photon Factory

    International Nuclear Information System (INIS)

    Maruyama, T.; Kashiwagi, T.; Kikuchi, T.; Toyoshima, A.; Kubota, M.; Ono, K.

    2007-01-01

    We have analyzed the data of encoders attached to optical elements and developed an on-line vibration diagnostics system of the monochromator. After eliminating the vibration source we have been able to improve the performance of the monochromator

  20. GSA On-Line Procurement Programs Lack Documentation and Reliability Testing

    National Research Council Canada - National Science Library

    Perry, Stephen

    2001-01-01

    .... For example, as part of an effort to improve the functioning of the government and achieve efficiencies of operations, the President has requested agencies to expand their use of on-line procurement in fiscal year 2OO2...

  1. On-line interrogation of pebble bed reactor fuel using passive gamma-ray spectrometry

    Science.gov (United States)

    Chen, Jianwei

    The Pebble Bed Reactor (PBR) is a helium-cooled, graphite-moderated high temperature nuclear power reactor. In addition to its inherently safe design, a unique feature of this reactor is its multipass fuel cycle in which graphite fuel pebbles (of varying enrichment) are randomly loaded and continuously circulated through the core until they reach their prescribed end-of-life burnup limit (˜80,000--100,000 MWD/MTU). Unlike the situation with conventional light water reactors (LWRs), depending solely on computational methods to perform in-core fuel management will be highly inaccurate. As a result, an on-line measurement approach becomes the only accurate method to assess whether a particular pebble has reached its end-of-life burnup limit. In this work, an investigation was performed to assess the feasibility of passive gamma-ray spectrometry assay as an approach for on-line interrogation of PBR fuel for the simultaneous determination of burnup and enrichment on a pebble-by-pebble basis. Due to the unavailability of irradiated or fresh pebbles, Monte Carlo simulations were used to study the gamma-ray spectra of the PBR fuel at various levels of burnup. A pebble depletion calculation was performed using the ORIGEN code, which yielded the gamma-ray source term that was introduced into the input of an MCNP simulation. The MCNP simulation assumed the use of a high-purity coaxial germanium detector. Due to the lack of one-group high temperature reactor cross sections for ORIGEN, a heterogeneous MCNP model was developed to describe a typical PBR core. Subsequently, the code MONTEBURNS was used to couple the MCNP model and ORIGEN. This approach allowed the development of the burnup-dependent, one-group spectral-averaged PBR cross sections to be used in the ORIGEN pebble depletion calculation. Based on the above studies, a relative approach for performing the measurements was established. The approach is based on using the relative activities of Np-239/I-132 in combination

  2. Earth is speaking: listen her! On-line questionnaire about anomalous geological and biological phenomena

    Science.gov (United States)

    Sciarra, Alessandra; Quattrocchi, Fedora; Cantucci, Barbara; Mazzarini, Francesco

    2014-05-01

    Earthquakes can be associated with non-seismic phenomena which may manifest many weeks before and after the main shock. These phenomena are characterized by ground fractures and soil liquefactions at surface often coupled with degassing events, chemical alterations of water and soils, changes in temperature and/or waters level in the epicentral area. Further manifestations include radio disturbances and light emissions. On the other hand, anomalous behavior of animals has been reported to occur before environmental changes. The co-occurrence of several phenomena may be considered as a signal of subsurface changes, and their analysis may be used as possible forecast indicators for seismic events, landslides, damages in infrastructure (e.g., dam) and groundwaters contamination. In order to obtain an accurate statistical analysis of these factors, a pre-crisis large database over a prolonged period of time is a pre-requisite. To this end, we elaborated a questionnaire for the population to pick up signs about anomalous phenomena like as: animal behavior, geological manifestations, effect on vegetation, degassing, changes on aquifers, wells and springs. After the January 25, 2013, mainshock (ML 4.8) in the Garfagnana seismic district, the Bagni di Lucca Municipality was selected as pilot site for testing this questionnaire. The complexity, variety and extension of this territory (165 kmq) sound suitable for this project. Bagni di Lucca is located in the southern border of the Garfagnana seismogenic source, characterized by the carbonate Mesozoic sequences and the Tertiary terrigenous sedimentary deposits of the Tuscan Nappe. The questionnaire was published on Bagni di Lucca web site (https://docs.google.com/file/d/0Bzw3vOYX47XoTGltTVJRbkJuajA/edit) in collaboration with Municipal Commitee, Local Civil Protection and Local Red Cross, and sent by ordinary mail to the citizenry. It is possible to answer to the questionnaire, also anonymously, direct on line (https

  3. On-line monitoring of water amount in fresh concrete by radioactive-wave method

    International Nuclear Information System (INIS)

    Kemi, T.; Arai, M.; Enomoto, S.; Suzki, K.; Kumahara, Y.

    2003-01-01

    The committee on nondestructive inspection for steel reinforced concrete structures in the Federation of Construction Materials Industries, Japan has published a proposed standard for on-line monitoring of water amount in fresh concrete by the radioactive wave method. By applying a neutron technique, water amount in fresh concrete is estimated continuously from the energy consumption of neutron due to hydrogen. A standard is discussed along with results of verification tests. Thus, on-line monitoring for water amount is proposed

  4. Beyond accessibility? Toward an on-line and memory-based model of framing effects

    OpenAIRE

    Matthes, Jörg

    2007-01-01

    This theoretical article investigates the effects of media frames on individuals' judgments. In contrast to previous theorizing, we suggest that framing scholars should embrace both, on-line and memory-based judgment formation processes. Based on that premise, we propose a model that distinguishes between two phases of framing effects. Along the first phase, the media's framing contributes to the formation of an on-line or a memory-based judgment. The second phase describes six hypothetical r...

  5. Challenges and Opportunities in ‘Last Mile’ Logistics for On-Line Food Retail

    OpenAIRE

    Trienekens , Jacques; Hvolby , Hans-Henrik; Turner , Paul

    2017-01-01

    Part 2: Production Management in Food Supply Chains; International audience; Conventional approaches to logistics for food retail continue to be challenged by the rapid growth of on-line food retail. At the same time, ‘last mile’ logistics optimization for on-line retail also face challenges as changing consumer expectations, habits and purchasing patterns intersect with the increasing density of urban environments. Numerous considerations are already in play around servicing of last mile log...

  6. Predictions of On-Line Banks' Fraudulent: A Study on Discriminant Analysis.

    OpenAIRE

    Gabriel Joseph Mukungu; Gwangyong Gim

    2014-01-01

    The information and communication technology (ICT) is growing fast in the community along with some risks. The on-line banks' fraudulent are increasing dramatically resulting in the loss of money and retardate the growth on economic development. Some law enforcers like Tanzanian police yet use the traditional prevention technologies to investigate these on-line banks' fraudulent cases mainly known as cyber crimes. For the purpose of this study, 150 data were collected as cyber...

  7. On-line marketing - princip aukce mění svět reklamy.

    OpenAIRE

    Jankovič, Zdeněk

    2009-01-01

    Diploma thesis 'On-line marketing - Principle of an auction changes the world of advertising' is about internet as a medium, on-line commercial communications, search engines and performance marketing. This thesis is divided into three parts. First part is about internet as a medium and actual situation on the Czech internet market. Second part describes a marketing communication mix on the internet, forms of online advertisement and pros and cons of online advertising. Third part deals with ...

  8. On-Line Path Generation and Tracking for High-Speed Wheeled Autonomous Vehicles

    Science.gov (United States)

    2006-02-17

    On-Line Path Generation and Tracking for High-Speed Wheeled Autonomous Vehicles Report Title ABSTRACT In this work we proposed two semi-analytic...298-102 Enclosure 1 On-Line Path Generation and Tracking for High-Speed Wheeled Autonomous Vehicles by...Specifically, the following problems will be addressed during this project: 2.1 Challenges The problem of trajectory planning for high-speed autonomous vehicles is

  9. Development of On-Line High Performance Liquid Chromatography (HPLC)-Biochemical Detection Methods as Tools in the Identification of Bioactives

    Science.gov (United States)

    Malherbe, Christiaan J.; de Beer, Dalene; Joubert, Elizabeth

    2012-01-01

    Biochemical detection (BCD) methods are commonly used to screen plant extracts for specific biological activities in batch assays. Traditionally, bioactives in the most active extracts were identified through time-consuming bio-assay guided fractionation until single active compounds could be isolated. Not only are isolation procedures often tedious, but they could also lead to artifact formation. On-line coupling of BCD assays to high performance liquid chromatography (HPLC) is gaining ground as a high resolution screening technique to overcome problems associated with pre-isolation by measuring the effects of compounds post-column directly after separation. To date, several on-line HPLC-BCD assays, applied to whole plant extracts and mixtures, have been published. In this review the focus will fall on enzyme-based, receptor-based and antioxidant assays. PMID:22489144

  10. A fixed incore based system for an on line core margin monitoring

    International Nuclear Information System (INIS)

    Mourlevat, J. L.; Carrasco, M.

    2002-01-01

    FRAMATOME-ANP has developed a new core monitoring system which is based on measurements coming from fixed incore sensors and on a 3D power distribution on line reconstruction. After selecting the rhodium self powered neutron detectors as fixed incore sensors, a first step of this development consisted in testing this kind of sensors in the French Golfech Unit 2 reactor (4L, 1300 MWe). (Author)

  11. Human interface for personal information systems. On-line handwriting recognition; Pasonaru joho kiki ni okeru human interface. On-line tegaki ninshiki

    Energy Technology Data Exchange (ETDEWEB)

    Morita, T. [Sharp Corp., Osaka (Japan)

    1996-01-05

    Most of information devices used in the business field use keyboards for the inputting measure, but keyboards are rather awkward for personal use. In contrast to this, the pen input method which everybody can use easily is a product of the latest development. In this articles, on-line handwritten letter recognition is roughly explained which is the basic technique of pen input. Pen input has a demerit that its letter inputting speed is slow, but has much more merits that Chinese ideographs can be directly input, figures, handwritten memoranda, etc. are treated likewise, the device itself can be made compact and no noise is made. The on-line letter recognition methods now used practically can be roughly divided into the pattern matching method and the basic stroke method. Each of them has its own merits and demerits. For the current on-line handwritten letter recognition, the condition is necessary to handwritten a letter in the square style (kaisho) and carefully within the framework for letter entry upon writing, and for this arrangement, input is performed through the work processes of pretreatment/feature extraction, stroke recognition, letter comparison, detail discrimination, and after-treatment. 3 refs., 7 figs.

  12. Enhancing communication skills for pediatric visits through on-line training using video demonstrations

    Directory of Open Access Journals (Sweden)

    Wissow Larry

    2008-02-01

    Full Text Available Abstract Background Training in communication skills for health professionals is important, but there are substantial barriers to individual in-person training for practicing clinicians. We evaluated the feasibility and desirability of on-line training and sought suggestions for future courses. Methods Based on successful in-person curricula for communication skills and our previous on-line curricula, we created an on-line course consisting of 28 modules (4.75 hours CME credit about communication skills during pediatric visits that included a mental health concern; each module included a brief case, a multiple choice question, an explanation, and a 1–2 minute video demonstrating key skills. Specific communication skills included: greeting, setting an agenda, discussing diagnosis and treatment, and managing negative interactions. The course was announced by emails in spring, 2007; the course was available on-line for 60 days; we aimed to enroll 50 clinicians. Outcomes were analyzed for those who evaluated the course within 75 days of its initial availability. Results Overall, 61 clinicians registered, of whom most were nurses (N = 24, physicians (N = 22, or psychologists or social workers (N = 12. Of the 36 (59% clinicians who evaluated the course, over 85% agreed that all course objectives had been met; over 90% reported greater confidence in greetings and agenda-setting; and over 80% reported greater confidence in discussing diagnosis and treatment and managing negative interactions. Nearly all, 97% would recommend the course to other clinicians and trainees. Suggestions for improvement included a library of additional video vignettes and written materials to accompany the on-line training. Conclusion On-line training in communication skills for pediatric mental health visits is feasible, desirable and associated with increased confidence in key skills. Positive feedback from clinicians suggests that a comparison of on-line versus in

  13. Comportamento do Consumidor On-line: a perspectiva da teoria do fluxoOn-line Consumer Behavior: the flow theory perspectiveComportamiento del consumidor On-line: la perspectiva de la teoría del flujo

    Directory of Open Access Journals (Sweden)

    FARIAS, Salomão Alencar de

    2008-03-01

    Full Text Available RESUMOEste artigo investiga o comportamento do consumidor on-line com base no fluxo, definido como a sensação holística que as pessoas sentem quando agem com total envolvimento em uma atividade (CSIKSZENTMIHALYI, 1975. Emprega-se essa teoria para melhor compreender o comportamento de compra pela Internet, embora seja um conceito ainda confuso na literatura do comportamento do consumidor, pois que não existe um consenso a respeito de quais os fatores antecedem, caracterizam ou são conseqüências do estado de fluxo. Desse modo, esta pesquisa buscou identificar os construtos, relacionados ao estado de fluxo, que devem fazer parte de um esquema de comportamento de compra on-line, além de indicar qual a sua aplicabilidade para o alcance da satisfação do consumidor na compra pela rede. Para tanto, foi utilizada uma metodologia de caráter descritivo com aplicação de um survey junto a uma amostra de 237 consumidores do varejo eletrônico. Os dados coletados foram analisados por meio de técnicas estatísticas multivariadas. Os resultados indicaram que o ambiente on-line e a telepresença antecedem o fluxo que, por sua vez, está associado ao comportamento exploratório, efeito positivo do processo de navegação, compra e satisfação com o processo de compra.ABSTRACTThis article investigates the on-line consumer behavior based on the flow theory, defined as the holistic sensation that people feel when acting with total involvement in an activity (CSIKSZENTMIHALYI, 1975. This theory has been used for better understanding the purchase behavior through the Internet, although this concept is still not sufficiently clear in consumer behavior literature, since it does not exist a consensus regarding which factors that precede, characterize or are consequences of the flow state. Thus, the present research was aimed at identifying the constructs related to the flow state that must be part of an on-line purchase behavior framework, indicating which

  14. Preferred Methods of Learning for Nursing Students in an On-Line Degree Program.

    Science.gov (United States)

    Hampton, Debra; Pearce, Patricia F; Moser, Debra K

    Investigators have demonstrated that on-line courses result in effective learning outcomes, but limited information has been published related to preferred teaching strategies. Delivery of on-line courses requires various teaching methods to facilitate interaction between students, content, and technology. The purposes of this study were to understand student teaching/learning preferences in on-line courses to include (a) differences in preferred teaching/learning methods for on-line nursing students across generations and (b) which teaching strategies students found to be most engaging and effective. Participants were recruited from 2 accredited, private school nursing programs (N=944) that admit students from across the United States and deliver courses on-line. Participants provided implied consent, and 217 (23%) students completed the on-line survey. Thirty-two percent of the students were from the Baby Boomer generation (1946-1964), 48% from Generation X (1965-1980), and 20% from the Millennial Generation (born after 1980). The preferred teaching/learning methods for students were videos or narrated PowerPoint presentations, followed by synchronous Adobe Connect educations sessions, assigned journal article reading, and e-mail dialog with the instructor. The top 2 methods identified by participants as the most energizing/engaging and most effective for learning were videos or narrated PowerPoint presentations and case studies. The teaching/learning method least preferred by participants and that was the least energizing/engaging was group collaborative projects with other students; the method that was the least effective for learning was wikis. Baby Boomers and Generation X participants had a significantly greater preference for discussion board (PBaby Boomer and Generation X students and rated on-line games as significantly more energizing/engaging and more effective for learning (PBaby Boomer and Generation X students. In conclusion, the results of this

  15. On-line stable isotope measurements during plant and soil gas exchange

    International Nuclear Information System (INIS)

    Yakir, D.

    2001-01-01

    Recent techniques for on-line stable isotope measurements during plant and soil exchange of CO 2 and/or water vapor are briefly reviewed. For CO 2 , these techniques provide means for on-line measurements of isotopic discrimination during CO 2 exchange by leaves in the laboratory and in the field, of isotopic discrimination during soil respiration and during soil-atmosphere CO 2 exchange, and of isotopic discrimination in O 2 during plant respiration. For water vapor, these techniques provide means to measure oxygen isotopic composition of water vapor during leaf transpiration and for the analysis of sub microliter condensed water vapor samples. Most of these techniques involve on-line sampling of CO 2 and water vapor from a dynamic, intact soil or plant system. In the laboratory, these systems also allow on-line isotopic analysis by continuous-flow isotope ratio mass spectrometry. The information obtained with these on-line techniques is becoming increasingly valuable, and often critical, for ecophysiologial research and in the study of biosphere-atmosphere interactions. (author)

  16. On-Line Monitoring of Instrument Channel Performance in Nuclear Power Plant Using PEANO

    International Nuclear Information System (INIS)

    Fantoni, Paolo F.; Hoffmann, Mario; Shankar, Ramesh; Davis, Eddie L.

    2002-01-01

    On-Line monitoring evaluates instrument channel performance by assessing its consistency with other plant indications. Industry and EPRI experience at several plants has shown this overall approach to be very effective in identifying instrument channels that are exhibiting degrading or inconsistent performance characteristics. On-Line monitoring of instrument channels provides information about the condition of the monitored channels through accurate, more frequent monitoring of each channel's performance over time. This type of performance monitoring is a methodology that offers an alternate approach to traditional time-directed calibration. On-line monitoring of these channels can provide an assessment of instrument performance and provide a basis for determining when adjustments are necessary. Elimination or reduction of unnecessary field calibrations can reduce associated labor costs, reduce personnel radiation exposure and reduce the potential for miss-calibration. PEANO is a system for on-line calibration monitoring developed in the years 1995-2000 at the Institutt for energiteknikk (IFE), Norway, which makes use of Artificial Intelligence techniques for its purpose. The system has been tested successfully in Europe in off-line tests with EDF (France), Tecnatom (Spain) and ENEA (Italy). PEANO is currently installed and used for on-line monitoring at the HBWR reactor in Halden. This paper describes the results of performance tests on PEANO with real data from a US PWR plant, in the framework of a co-operation among IFE, EPRI and Edan Engineering, to evaluate the potentials of PEANO for future installations in US nuclear plants. (authors)

  17. On-line measurement with automatic emulsion analysis system and off-line data processing (E531 neutrino experiment)

    International Nuclear Information System (INIS)

    Miyanishi, Motoaki

    1984-01-01

    The automatic emulsion analysis system developed by Nagoya cosmic ray observation group was practically used for the experiment (FNAL-E531) on determining the lifetime of charm particles for the first time in the world, and achieved a great successful result. The system consists of four large precise coordinate-measuring stages capable of conducting simultaneous measurement and multiple (currently four) DOMS (digitized on-line microscope), supported with one mini-computer (ECLIPS S/130). The purpose of E531 experiment was the determination of charm particle lifetime. The experiment was carried out at FNAL, USA, and by the irradiation of wide band ν sub(μ) beam equivalent to 7 x 10 18 of 350 GeV/c protons. The detector was a hybrid system of emulsions and a counter spectrometer. The scan of neutrino reaction, the scan of charm particles, and charm event measurement were analyzed in emulsions, and the on-line programs for-respective analyses were created. Nagoya group has found 726 neutrino reactions in the first run, obtained 37 charm particle candidates, and found 1442 neutrino reactions in the second run, and obtained 56 charm particle candidates. The capability of the automatic emulsion analysis system in terms of the time equired for analysis is in total 3.5 hours per event; 15 minutes for C.S. scan, 15 minutes for coupling to module, 20 minutes for tracing to vertex, 1 hour for neutrino reaction measurement, 10 minutes for offline data processing and 1.5 hours for charm particle scanning. (Wakatsuki, Y.)

  18. On-line liquid chromatography/tandem mass spectrometry simultaneous determination of opiates, cocainics and amphetamines in dried blood spots.

    Science.gov (United States)

    Saussereau, E; Lacroix, C; Gaulier, J M; Goulle, J P

    2012-02-15

    A novel approach has been developed for the illicit drugs quantitative determination using dried blood spots (DBS) on filter paper. The illicit drugs tested were opiates (morphine and its 3- and 6-glucuronide metabolites, codeine, 6-monoacetylmorphine), cocainics (ecgonine methylester, benzoylecgonine, cocaine, cocaethylene) and amphetamines (amphetamine, methamphetamine, MDA, MDMA, MDEA). The described method, requiring a small blood volume, is based on high performance liquid chromatography coupled to tandem mass spectrometry using on-line extraction. A Whatman card 903 was spotted with 30μL of whole blood and left overnight to dry at room temperature. A 3-mm diameter disk was removed using a manual punch, suspended in 150μL of water for 10min with ultrasonication, and then 100μL was injected in the on-line LC-MS/MS system. An Oasis HLB was used as an extraction column and a C18 Atlantis as an analytical column. The chromatographic cycle was performed with 20mM ammonium formate buffer (pH 2.8) (solvent A) and acetonitrile/solvent A (90:10, v/v) gradient in 16min. Detection was performed in positive electrospray ionization mode (ESI+) with a Quattro Micro (Waters). Recoveries of all analytes were up to 80%. DBS were stored in duplicate at 4°C and -20°C for up to 6 months. Illicit drugs seemed to be much more stabled at -20°C. Furthermore, it was tested whether analysis of DBS may be as reliable as that of whole blood investigating authentic samples; significant correlations were obtained. This DBS assay has potential as rapid, sensitive and inexpensive option for the illicit drugs determination in small blood volumes, which seems of great interest in suspected cases of driving under the influence of drugs. Copyright © 2011 Elsevier B.V. All rights reserved.

  19. The influence of specific mechanical energy on cornmeal viscosity measured by an on-line system during twin-screw extrusion

    OpenAIRE

    CHANG, Y. K.; MARTINEZ-BUSTOS, F.; PARK, T. S.; KOKINI, J .L.

    1999-01-01

    The influence of specific mechanical energy (SME) on cornmeal viscosity during the twin-screw extrusion at feed moisture contents of 25 and 30% and screw speeds in the range from 100 to 500 rpm was measured. Cornmeal was extruded in a co-rotating, intermeshing twin-screw coupled to a slit die rheometer. One approach to the on-line rheological measurement is to use a slit die with the extruder. In the present work it was show that shear viscosity decreased as a function of SME. The viscosity o...

  20. On-line interprofessional learning: introducing constructivism through enquiry-based learning and peer review.

    Science.gov (United States)

    Hughes, Matthew; Ventura, Susie; Dando, Mark

    2004-08-01

    Interest in on-line methods of learning has accelerated in recent years. There has also been an interest in developing student-centred approaches to learning and interprofessional education. This paper illustrates the issues in designing a large (more than 700 students), on-line, inter-professional module for third year, undergraduate students drawn from nine professional healthcare courses and from four campus sites. It uses an enquiry-based learning approach. The learning theories of Piaget, Vygotsky and Schön are integrated with the on-line frameworks of Salmon and Collis et al., together with conclusions drawn from the literature and our own experiences, to produce a design that encourages students to learn through participation, re-iteration, peer-review and reflection. Consideration is given to improving student motivation and attitudes towards change, both in the design and the delivery of the module.

  1. A modular multi-microcomputer system for on-line vibration diagnostics

    International Nuclear Information System (INIS)

    Saedtler, E.

    1988-01-01

    A new modular multi-microprocessor system for on-line vibration monitoring and diagnostics of PWRs is described. The aim of the system is to make feasible an early detection of increasing failures in relevant regions of a reactor plant, to verify the mechanical integrity of the investigated components, and to improve therefore the operational safety of the plant. After a discussion of the implemented surveillance methods and algorithms, which are based on hierarchical structured identification (estimation) and statistical pattern recognition tools, the system architecture (software and hardware) is portrayed. The classification scheme itself works sequential so that samples (or features) can arrive on-line. This on-line classification is important in order to take necessary actions in time. Furthermore, the system has learning capabilities, which means it is adaptable to different, varying states and plant conditions. The main features of the system are presented and its contribution to an automation of complex surveillance and monitoring tasks is shown. (author)

  2. An on-line modified least-mean-square algorithm for training neurofuzzy controllers.

    Science.gov (United States)

    Tan, Woei Wan

    2007-04-01

    The problem hindering the use of data-driven modelling methods for training controllers on-line is the lack of control over the amount by which the plant is excited. As the operating schedule determines the information available on-line, the knowledge of the process may degrade if the setpoint remains constant for an extended period. This paper proposes an identification algorithm that alleviates "learning interference" by incorporating fuzzy theory into the normalized least-mean-square update rule. The ability of the proposed methodology to achieve faster learning is examined by employing the algorithm to train a neurofuzzy feedforward controller for controlling a liquid level process. Since the proposed identification strategy has similarities with the normalized least-mean-square update rule and the recursive least-square estimator, the on-line learning rates of these algorithms are also compared.

  3. Administering Spatial and Cognitive Instruments In-class and On-line: Are These Equivalent?

    Science.gov (United States)

    Williamson, Kenneth C.; Williamson, Vickie M.; Hinze, Scott R.

    2017-02-01

    Standardized, well-established paper-and-pencil tests, which measure spatial abilities or which measure reasoning abilities, have long been found to be predictive of success in the STEM (science, technology, engineering, and mathematics) fields. Instructors can use these tests for prediction of success and to inform instruction. A comparative administration of spatial visualization and cognitive reasoning tests, between in-class (proctored paper and pencil) and on-line (unproctored Internet) ( N = 457), was used to investigate and to determine whether the differing instrument formats yielded equal measures of spatial ability and reasoning ability in large first-semester general chemistry sections. Although some gender differences were found, findings suggest that some differences across administration formats, but that on-line administration had similar properties of predicting chemistry performance as the in-class version. Therefore, on-line administration is a viable option for instructors to consider especially when dealing with large classes.

  4. On-Line Monitoring of Fermentation Processes by Near Infrared and Fluorescence Spectroscopy

    DEFF Research Database (Denmark)

    Svendsen, Carina

    Monitoring and control of fermentation processes is important to ensure high product yield, product quality and product consistency. More knowledge on on-line analytical techniques such as near infrared and fluorescence spectroscopy is desired in the fermentation industry to increase the efficiency...... of on-line monitoring systems. The primary aim of this thesis is to elucidate and explore the dynamics in fermentation processes by spectroscopy. Though a number of successful on-line lab-scale monitoring systems have been reported, it seems that several challenges are still met, which limits the number...... of full-scale systems implemented in industrial fermentation processes. This thesis seeks to achieve a better understanding of the techniques near infrared and fluorescence spectroscopy and thereby to solve some of the challenges that are encountered. The thesis shows the advantages of applying real...

  5. On-line rituals: a new field of research: neo-pagan and Muslim cyber rituals

    Directory of Open Access Journals (Sweden)

    Göran Larsson

    2003-01-01

    Full Text Available Although secularisation and institutional specialisation have reduced the importance and influence of churchoriented religion, people still have a need for religion and transcendence. By looking at two so-called on-line rituals — a neo-pagan blot and a Muslim dhikr, the author examines and illustrates how religiosity may be articulated on the Internet. Although Internet research is often discussed in relation to methodological and theoretical problems, rituals performed on-line should be included in the academic study of religion. Common problems associated with Internet research (questions of representation, source criticism, etc. in themselves stimulate the development of new methods and theories for studying on-line religiosity.

  6. Software development for on-line computation with PDP 15/76 computer

    Energy Technology Data Exchange (ETDEWEB)

    Viyogi, Y P; Bhattacharjee, T K; De, S K; Basu, A K; Ganguly, N K [Bhabha Atomic Research Centre, Bombay (India). Variable Energy Cyclotron Project

    1979-01-01

    Two important capabilities have been incorporated in the on-line data processing system for the pulse height analysis at VEC, for the processing of data by using codes PHA1 and PHA2, the single parameter and dual parameter data acquisition programs. (1) RDMA is written in assembly language for randomly accessing any element of data from data filing devices. This increases the availability of core so that capability of processing programs can be enhanced. (2) PHARAD, also written in assembly language, converts data files created by acquisition programs into FORTRAN compatible files. These are very essential for on-line processing of data. The on-line data acqujsition and processing by PDP 15/76 using these facilities are discussed.

  7. Experience with on-line diagnostics for bushings and current transformers

    Energy Technology Data Exchange (ETDEWEB)

    Brusetti, R.

    2004-02-01

    The application of on-line diagnostic techniques is advocated as an alternative, under certain conditions, for the conventional off-line power factor test used to evaluate the condition of bushings and current transformers. Bushings which are tied to critical system apparatus or which cannot be readily removed from service are considered to be excellent candidates for on-line diagnostics. A case history involving 138-KV bushings is used to demonstrate the value of the on-line diagnostic system which, by taking into account power factor capacitance values along with the rate of change, not only detected the high power factor associated with the bushings, but allowed the high power factor bushings to continue operating with a known problem for over a year. With conventional testing, bushings that exhibited this level of power factor would typically be removed from service. 4 refs., 3 figs.

  8. On-line statistical processing of radiation detector pulse trains with time-varying count rates

    International Nuclear Information System (INIS)

    Apostolopoulos, G.

    2008-01-01

    Statistical analysis is of primary importance for the correct interpretation of nuclear measurements, due to the inherent random nature of radioactive decay processes. This paper discusses the application of statistical signal processing techniques to the random pulse trains generated by radiation detectors. The aims of the presented algorithms are: (i) continuous, on-line estimation of the underlying time-varying count rate θ(t) and its first-order derivative dθ/dt; (ii) detection of abrupt changes in both of these quantities and estimation of their new value after the change point. Maximum-likelihood techniques, based on the Poisson probability distribution, are employed for the on-line estimation of θ and dθ/dt. Detection of abrupt changes is achieved on the basis of the generalized likelihood ratio statistical test. The properties of the proposed algorithms are evaluated by extensive simulations and possible applications for on-line radiation monitoring are discussed

  9. Research on the Influence of Perceived Risk in Consumer On-line Purchasing Decision

    Science.gov (United States)

    Hong, Zhao; Yi, Li

    Perceived risk is an important factor that affects consumer's on-line shopping purchasing decision, through the perceived theories the consumer can know clearly which step owns higher risk in the whole shopping process, then learn how to prevent it, this process also strengthen the consumer confidence, thus lowering to know that the risk adjudicate to the feeling, so the essay has important and realistic meaning for further expand the electronic commerce. At first, investigate, collect, tidy up, analyze the questionnaire information, and thus get the primary data. Finally try to find out the influence of perceived risk to each stage of purchasing decision during consumer on-line shopping process with data and personal analytical. The paper is a complement to the local and existing perceived theories. The result of the study manifests that, the order of main perceived risks which felt by consumer during on-line shopping process are as follow: financial risk, the performance risk and service risk.

  10. On-line Shopping on B2C Markets in the Czech Republic

    Directory of Open Access Journals (Sweden)

    Pilík Michal

    2012-12-01

    Full Text Available The paper deals with the e-commerce theory and is aimed primarily at its usage in business-toconsumer markets. On-line purchasing management is increasing not only in the Czech Republic but also in Europe and all over the world. The customers who think rationally use on-line shopping because of money saving, speed delivery and the possibility of product comparison. This paper presents the results of a project financed by the Czech Science Foundation P403/11/ P175: The factors influencing customers’ on-line behaviour in e-commerce environment on B2C and B2B markets in the Czech Republic. 89 % of respondents use e-shops for buying products in the Czech Republic. 32 % of them use the Internet for regular purchases and 57 % of them irregularly. 11 % of respondents have not used e-shops yet.

  11. On-line data analysis and monitoring for H1 drift chambers

    International Nuclear Information System (INIS)

    Duellmann, D.

    1992-01-01

    The on-line monitoring, slow control and calibration of the H1 central jet chamber uses a VME multiprocessor system to perform the analysis and a connected Macintosh computer as graphical interface to the operator on shift. Tasks of this system are: Analysis of event data including on-line track search; on-line calibration from normal events and testpulse events; control of the high voltage and monitoring of settings and currents; monitoring of temperature, pressure and mixture of the chambergas. A program package is described which controls the dataflow between data aquisition, different VME CPUs and Macintosh. It allows to run off-line style programs for the different tasks. (orig.)

  12. Plasmodium species differentiation by non-expert on-line volunteers for remote malaria field diagnosis.

    Science.gov (United States)

    Ortiz-Ruiz, Alejandra; Postigo, María; Gil-Casanova, Sara; Cuadrado, Daniel; Bautista, José M; Rubio, José Miguel; Luengo-Oroz, Miguel; Linares, María

    2018-01-30

    Routine field diagnosis of malaria is a considerable challenge in rural and low resources endemic areas mainly due to lack of personnel, training and sample processing capacity. In addition, differential diagnosis of Plasmodium species has a high level of misdiagnosis. Real time remote microscopical diagnosis through on-line crowdsourcing platforms could be converted into an agile network to support diagnosis-based treatment and malaria control in low resources areas. This study explores whether accurate Plasmodium species identification-a critical step during the diagnosis protocol in order to choose the appropriate medication-is possible through the information provided by non-trained on-line volunteers. 88 volunteers have performed a series of questionnaires over 110 images to differentiate species (Plasmodium falciparum, Plasmodium ovale, Plasmodium vivax, Plasmodium malariae, Plasmodium knowlesi) and parasite staging from thin blood smear images digitalized with a smartphone camera adapted to the ocular of a conventional light microscope. Visual cues evaluated in the surveys include texture and colour, parasite shape and red blood size. On-line volunteers are able to discriminate Plasmodium species (P. falciparum, P. malariae, P. vivax, P. ovale, P. knowlesi) and stages in thin-blood smears according to visual cues observed on digitalized images of parasitized red blood cells. Friendly textual descriptions of the visual cues and specialized malaria terminology is key for volunteers learning and efficiency. On-line volunteers with short-training are able to differentiate malaria parasite species and parasite stages from digitalized thin smears based on simple visual cues (shape, size, texture and colour). While the accuracy of a single on-line expert is far from perfect, a single parasite classification obtained by combining the opinions of multiple on-line volunteers over the same smear, could improve accuracy and reliability of Plasmodium species

  13. Treatment of hepatic encephalopathy by on-line hemodiafiltration: a case series study

    Directory of Open Access Journals (Sweden)

    Sugiyama Mitsugi

    2010-05-01

    Full Text Available Abstract Background It is thought that a good survival rate of patients with acute liver failure can be achieved by establishing an artificial liver support system that reliably compensates liver function until the liver regenerates or a patient undergoes transplantation. We introduced a new artificial liver support system, on-line hemodiafiltration, in patients with acute liver failure. Methods This case series study was conducted from May 2001 to October 2008 at the medical intensive care unit of a tertiary care academic medical center. Seventeen consecutive patients who admitted to our hospital presenting with acute liver failure were treated with artificial liver support including daily on-line hemodiafiltration and plasma exchange. Results After 4.9 ± 0.7 (mean ± SD on-line hemodiafiltration sessions, 16 of 17 (94.1% patients completely recovered from hepatic encephalopathy and maintained consciousness for 16.4 ± 3.4 (7-55 days until discontinuation of artificial liver support (a total of 14.4 ± 2.6 [6-47] on-line hemodiafiltration sessions. Significant correlation was observed between the degree of encephalopathy and number of sessions of on-line HDF required for recovery of consciousness. Of the 16 patients who recovered consciousness, 7 fully recovered and returned to society with no cognitive sequelae, 3 died of complications of acute liver failure except brain edema, and the remaining 6 were candidates for liver transplantation; 2 of them received living-related liver transplantation but 4 died without transplantation after discontinuation of therapy. Conclusions On-line hemodiafiltration was effective in patients with acute liver failure, and consciousness was maintained for the duration of artificial liver support, even in those in whom it was considered that hepatic function was completely abolished.

  14. On-line Peer Review in Teaching Design-oriented Courses

    Directory of Open Access Journals (Sweden)

    Hai Ning

    2004-02-01

    Full Text Available Peer review has been one of the very important designfacilitating processes practiced in education field, particularly in design-oriented courses such as MIT's 2.007 Robot Design. Typically students exchange ideas sketched on a piece of paper and critique on each other's design within a small team. We designed PREP web application backed up by a range of web services that handle the peer-review process on-line, and we argue that this is a significant step towards supporting designoriented course on-line. We believe that the lessons learned could be applied to other interested institutes that offer designoriented courses.

  15. Experience gained upon industrial application of on-line activation analysis in flotation

    International Nuclear Information System (INIS)

    Braun, H.; Riffel, F.

    1979-01-01

    At the Karlsruhe Nuclear Research Center an anlyzer was developed which allows continuous evaluation of the valuable minerals content in process streams. Experience is reported which has been gathered in several weeks of industrial application in a fluorspar flotation plant, the first industrial scale application of on-line activation analysis in Europe. The use has shown that with the equipment presented on-line monitoring with the desired accuracy is possible of all the strategically important points. This is of considerable importance for the economy of the process. (orig.) [de

  16. An on-line data acquisition system based on Norsk-Data ND-560 computer

    International Nuclear Information System (INIS)

    Bandyopadhyay, A.; Roy, A.; Dey, S.K.; Bhattacharya, S.; Bhowmik, R.K.

    1987-01-01

    This paper describes a high-speed data acquisition system based on CAMAC for Norsk Data ND-560 computer operating in a multiuser environment. As opposed to the present trend, the system has been implemented with minimum hardware at CAMAC level taking advantage of the dual processors of ND-560. The package consists of several coordinated tasks running in the two CPUs which acquire data, record on tape, permit on-line analysis and display the data and perform related control operations. It has been used in several experiments at VECC and its performance in on-line experiments is reported. (orig.)

  17. Consumer opinions about print and on-line pay contents according to primary research results

    Directory of Open Access Journals (Sweden)

    Katalin Jäckel

    2014-07-01

    Full Text Available In this paper we present the sub results of a primer research project process. Themain objective of survey was to explore the effectof the digitalization onto themedia consumption habits, with a strange look ontothe print and the on-line paycontents. During the research we applied qualitative and quantitative methods. Weanalysed the most important changes of the media consumption preferences withthe help of expert interviews and consumers surveystaking the influencing role ofthe international trends onto consideration. Basedon the results of the researchcan be characterised the main target groups of on-line pay contents and the printmediums.

  18. Marketing klubu HC Olomouc zaměřený na on-line komunikaci

    OpenAIRE

    Kramář, Josef

    2015-01-01

    The theoretical part of this Bachelor Thesis on the topic "Marketing of Ice-hockey club Olomouc focusing on on-line communication" has got the aim of introducing general marketing, internet marketing, social sites on the internet and also the specifics of sports marketing. The practical part then introduces the Ice-hockey club Olomouc, assesses the current state of its on-line marketing communication and shows a comparison with its competitors on social sites. There will be also a questionnai...

  19. A nuclear on-line sensor for continuous control of vanadium content in oil pipelines

    International Nuclear Information System (INIS)

    Rizk, R.A.M.

    1989-01-01

    Trace amounts of vanadium in crude oil and in heavy distillate fuels are very harmful due to their corrosive action. Thus the necessity arises for continuous control of the vanadium content in oil pipelines. Moreover, the development of a nuclear on-line sensor that can continuously analyze the vanadium content in oil pipelines may lead to a better control of processing operations. In this paper a feasibility study for on-line analysis of vanadium in crude oil by means of neutron activation analysis is presented. (author)

  20. Probabilistic Forecasting for On-line Operation of Urban Drainage Systems

    DEFF Research Database (Denmark)

    Löwe, Roland

    This thesis deals with the generation of probabilistic forecasts in urban hydrology. In particular, we focus on the case of runoff forecasting for real-time control (RTC) on horizons of up to two hours. For the generation of probabilistic on-line runoff forecasts, we apply the stochastic grey...... and forecasts have on on-line runoff forecast quality. Finally, we implement the stochastic grey-box model approach in a real-world real-time control (RTC) setup and study how RTC can benefit from a dynamic quantification of runoff forecast uncertainty....