WorldWideScience

Sample records for heat source based

  1. Cooling Load Estimation in the Building Based On Heat Sources

    Science.gov (United States)

    Chairani; Sulistyo, S.; Widyawan

    2017-05-01

    Heating, ventilation and air conditioning (HVAC) is the largest source of energy consumption. In this research, we discuss cooling load in the room by considering the different heat source and the number of occupancy. Energy cooling load is affected by external and internal heat sources. External cooling load in this discussion include convection outdoor/exterior using the DOE-2 algorithm, calculation of heat using Thermal Analysis Research Program (TARP), and Conduction Transfer Function (CTF). The internal cooling load is calculated based on the activity of the occupants in the office, a number of occupants, heat gain from lighting, and heat gain from electrics equipment. Weather data used is Surakarta weather and design day used is Jakarta design day. We use the ASHRAE standard for building materials and the metabolic of occupants while on the activity. The results show that the number of occupancies have an influence of cooling load. A large number of occupancy will cause the cooling load is great as well.

  2. Life cycle assessment of base-load heat sources for district heating system options

    Energy Technology Data Exchange (ETDEWEB)

    Ghafghazi, Saeed [University of British Columbia, Vancouver; Sowlati, T. [University of British Columbia, Vancouver; Sokhansanj, Shahabaddine [ORNL; Melin, Staffan [Delta Research Corporation

    2011-03-01

    Purpose There has been an increased interest in utilizing renewable energy sources in district heating systems. District heating systems are centralized systems that provide heat for residential and commercial buildings in a community. While various renewable and conventional energy sources can be used in such systems, many stakeholders are interested in choosing the feasible option with the least environmental impacts. This paper evaluates and compares environmental burdens of alternative energy source options for the base load of a district heating center in Vancouver, British Columbia (BC) using the life cycle assessment method. The considered energy sources include natural gas, wood pellet, sewer heat, and ground heat. Methods The life cycle stages considered in the LCA model cover all stages from fuel production, fuel transmission/transportation, construction, operation, and finally demolition of the district heating system. The impact categories were analyzed based on the IMPACT 2002+ method. Results and discussion On a life-cycle basis, the global warming effect of renewable energy options were at least 200 kgeqCO2 less than that of the natural gas option per MWh of heat produced by the base load system. It was concluded that less than 25% of the upstream global warming impact associated with the wood pellet energy source option was due to transportation activities and about 50% of that was resulted from wood pellet production processes. In comparison with other energy options, the wood pellets option has higher impacts on respiratory of inorganics, terrestrial ecotoxicity, acidification, and nutrification categories. Among renewable options, the global warming impact of heat pump options in the studied case in Vancouver, BC, were lower than the wood pellet option due to BC's low carbon electricity generation profile. Ozone layer depletion and mineral extraction were the highest for the heat pump options due to extensive construction required for these

  3. Heat and power sources based on nuclear shipbuilding technologies

    Energy Technology Data Exchange (ETDEWEB)

    Veshnyakov, K.; Fadeev, Y.; Panov, Y.; Polunichev, V. [JSC Afrikantov OKBM, Nizhny Novgorod (Russian Federation)

    2009-07-01

    The report gives information on the application of power units with small-power nuclear reactors as advanced energy sources to provide world consumers with electric power, domestic and industrial heat and fresh water. The report describes the technical concept of ABV unified reactor plant (RP) for floating and ground small power plants (SPP) developed in JSC 'Afrikantov OKBM'. The report contains the technical specification of the ABV RP utilizing an integral water-cooled reactor with thermal power of 38 to 45 MW, natural coolant circulation and improved inherent safety, as well as main characteristics of the reactor and core fuel ensuring acceptable mobility of the RP and NPP as a whole. The indicated refueling interval is 10-12 years. The report gives a detailed description of the concept for RP safety provision and compliance with international radiation and nuclear safety requirements, as well as the description of passive and other safety systems securing stability to any low-probability internal events, personnel errors and external impacts. The report provides data on application and technological properties of the floating and ground SPPs with a unified ABV RP; absence of spent fuel and radioactive waste at floating nuclear power plants (FNPP); FNPP transportation to consumers in a ready-to-operate state; arrangement, operation and disposal requirements.

  4. Ablation Properties of the Carbon-Based Composites Used in Artificial Heat Source Under Fire Accident

    Institute of Scientific and Technical Information of China (English)

    TANG; Xian; HUANG; Jin-ming; ZHOU; Shao-jian; LUO; Zhi-fu

    2012-01-01

    <正>The ablation properties of the carbon-based composites used in artificial heat source under fire accident were investigated by the arc heater. In this work, we tested the carbon-based composites referring to Fig. 1. Their linear/mass ablation ratio and ablation morphologies were studied. The results showed that the carbon-based composites used in artificial heat source behaved well

  5. Optimum load distribution between heat sources based on the Cournot model

    Science.gov (United States)

    Penkovskii, A. V.; Stennikov, V. A.; Khamisov, O. V.

    2015-08-01

    One of the widespread models of the heat supply of consumers, which is represented in the "Single buyer" format, is considered. The methodological base proposed for its description and investigation presents the use of principles of the theory of games, basic propositions of microeconomics, and models and methods of the theory of hydraulic circuits. The original mathematical model of the heat supply system operating under conditions of the "Single buyer" organizational structure provides the derivation of a solution satisfying the market Nash equilibrium. The distinctive feature of the developed mathematical model is that, along with problems solved traditionally within the bounds of bilateral relations of heat energy sources-heat consumer, it considers a network component with its inherent physicotechnical properties of the heat network and business factors connected with costs of the production and transportation of heat energy. This approach gives the possibility to determine optimum levels of load of heat energy sources. These levels provide the given heat energy demand of consumers subject to the maximum profit earning of heat energy sources and the fulfillment of conditions for formation of minimum heat network costs for a specified time. The practical realization of the search of market equilibrium is considered by the example of a heat supply system with two heat energy sources operating on integrated heat networks. The mathematical approach to the solution search is represented in the graphical form and illustrates computations based on the stepwise iteration procedure for optimization of levels of loading of heat energy sources (groping procedure by Cournot) with the corresponding computation of the heat energy price for consumers.

  6. Cluster banding heat source model

    Institute of Scientific and Technical Information of China (English)

    Zhang Liguo; Ji Shude; Yang Jianguo; Fang Hongyuan; Li Yafan

    2006-01-01

    Concept of cluster banding heat source model is put forward for the problem of overmany increment steps in the process of numerical simulation of large welding structures, and expression of cluster banding heat source model is deduced based on energy conservation law.Because the expression of cluster banding heat source model deduced is suitable for random weld width, quantitative analysis of welding stress field for large welding structures which have regular welds can be made quickly.

  7. Research on a Household Dual Heat Source Heat Pump Water Heater with Preheater Based on ASPEN PLUS

    Directory of Open Access Journals (Sweden)

    Xiang Gou

    2016-12-01

    Full Text Available This article proposes a dual heat source heat pump bathroom unit with preheater which is feasible for a single family. The system effectively integrates the air source heat pump (ASHP and wastewater source heat pump (WSHP technologies, and incorporates a preheater to recover shower wastewater heat and thus improve the total coefficient of performance (COP of the system, and it has no electric auxiliary heating device, which is favorable to improve the security of the system operation. The process simulation software ASPEN PLUS, widely used in the design and optimization of thermodynamic systems, was used to simulate various cases of system use and to analyze the impact of the preheater on the system. The average COP value of a system with preheater is 6.588 and without preheater it is 4.677. Based on the optimization and analysis, under the standard conditions of air at 25 °C, relative humidity of 70%, wastewater at 35 °C, wastewater flow rate of 0.07 kg/s, tap water at 15 °C, and condenser outlet water temperature at 50 °C, the theoretical COP of the system can reach 9.784 at an evaporating temperature of 14.96 °C, condensing temperature of 48.74 °C, and preheated water temperature of 27.19 °C.

  8. [Urban heat island effect based on urban heat island source and sink indices in Shenyang, Northeast China].

    Science.gov (United States)

    Li, Li-Guang; Xu, Shen-Lai; Wang, Hong-Bo; Zhao, Zi-Qi; Cai, Fu; Wu, Jin-Wen; Chen, Peng-Shi; Zhang, Yu-Shu

    2013-12-01

    Based on the remote images in 2001 and 2010, the source and sink areas of urban heat island (UHI) in Shenyang City, Northeast China were determined by GIS technique. The effect of urban regional landscape pattern on UHI effect was assessed with land surface temperature (LST), area rate index (CI) of the source and sink areas and intensity index (LI) of heat island. The results indicated that the land use type changed significantly from 2001 to 2010, which significantly changed the source and sink areas of UHI, especially in the second and third circle regions. The source and sink areas were 94.3% and 5.7% in the first circle region, 64.0% and 36.0% in the third circle region in 2001, while they were 93.4% and 6.6%, 70.2% and 29.8% in 2010, respectively. It suggested that the land use pattern extended by a round shape in Shenyang led to the corresponding UHI pattern. The LST in the study area tended to decrease from the first circle region to the third. The UHI intensity was characterized with a single center in 2001 and with several centers in 2010, and the grade of UHI intensity was in a decreasing trend from 2001 to 2010. The absolute value of CI increased from the first circle region to the third, and the L1 was close to 1, suggesting the change in land use pattern had no significant influence on UHI in Shenyang.

  9. Performance characteristic of thermosyphon heat pipe at radiant heat source

    Science.gov (United States)

    Hrabovský, Peter; Papučík, Štefan; Kaduchová, Katarína

    2016-06-01

    This article discusses about device, which is called heat pipe. This device is with heat source with radiant heat source. Heat pipe is device with high efficiency of heat transfer. The heat pipe, which is describe in this article is termosyphon heat pipe. The experiment with termosyphon heat pipe get a result. On the base of result, it will be in future to create mathematical model in Ansys. Thermosyphon heat pipe is made of copper and distilled water is working fluid. The significance of this experiment consists in getting of the heat transfer and performance characteristic. On the basis of measured and calculated data can be constructed the plots.

  10. Finite Volume Based Computer Program for Ground Source Heat Pump System

    Energy Technology Data Exchange (ETDEWEB)

    Menart, James A. [Wright State University

    2013-02-22

    This report is a compilation of the work that has been done on the grant DE-EE0002805 entitled ?Finite Volume Based Computer Program for Ground Source Heat Pump Systems.? The goal of this project was to develop a detailed computer simulation tool for GSHP (ground source heat pump) heating and cooling systems. Two such tools were developed as part of this DOE (Department of Energy) grant; the first is a two-dimensional computer program called GEO2D and the second is a three-dimensional computer program called GEO3D. Both of these simulation tools provide an extensive array of results to the user. A unique aspect of both these simulation tools is the complete temperature profile information calculated and presented. Complete temperature profiles throughout the ground, casing, tube wall, and fluid are provided as a function of time. The fluid temperatures from and to the heat pump, as a function of time, are also provided. In addition to temperature information, detailed heat rate information at several locations as a function of time is determined. Heat rates between the heat pump and the building indoor environment, between the working fluid and the heat pump, and between the working fluid and the ground are computed. The heat rates between the ground and the working fluid are calculated as a function time and position along the ground loop. The heating and cooling loads of the building being fitted with a GSHP are determined with the computer program developed by DOE called ENERGYPLUS. Lastly COP (coefficient of performance) results as a function of time are provided. Both the two-dimensional and three-dimensional computer programs developed as part of this work are based upon a detailed finite volume solution of the energy equation for the ground and ground loop. Real heat pump characteristics are entered into the program and used to model the heat pump performance. Thus these computer tools simulate the coupled performance of the ground loop and the heat pump

  11. Recovery Act: Finite Volume Based Computer Program for Ground Source Heat Pump Systems

    Energy Technology Data Exchange (ETDEWEB)

    James A Menart, Professor

    2013-02-22

    This report is a compilation of the work that has been done on the grant DE-EE0002805 entitled Finite Volume Based Computer Program for Ground Source Heat Pump Systems. The goal of this project was to develop a detailed computer simulation tool for GSHP (ground source heat pump) heating and cooling systems. Two such tools were developed as part of this DOE (Department of Energy) grant; the first is a two-dimensional computer program called GEO2D and the second is a three-dimensional computer program called GEO3D. Both of these simulation tools provide an extensive array of results to the user. A unique aspect of both these simulation tools is the complete temperature profile information calculated and presented. Complete temperature profiles throughout the ground, casing, tube wall, and fluid are provided as a function of time. The fluid temperatures from and to the heat pump, as a function of time, are also provided. In addition to temperature information, detailed heat rate information at several locations as a function of time is determined. Heat rates between the heat pump and the building indoor environment, between the working fluid and the heat pump, and between the working fluid and the ground are computed. The heat rates between the ground and the working fluid are calculated as a function time and position along the ground loop. The heating and cooling loads of the building being fitted with a GSHP are determined with the computer program developed by DOE called ENERGYPLUS. Lastly COP (coefficient of performance) results as a function of time are provided. Both the two-dimensional and three-dimensional computer programs developed as part of this work are based upon a detailed finite volume solution of the energy equation for the ground and ground loop. Real heat pump characteristics are entered into the program and used to model the heat pump performance. Thus these computer tools simulate the coupled performance of the ground loop and the heat pump. The

  12. 基于复合热源的热泵型空调器%Heat pump air conditioner based on multiple heat sources

    Institute of Scientific and Technical Information of China (English)

    吴国珊; 凌勋

    2012-01-01

    It is proposed that the air-water multiple heat sources could be the heat source of heat pump air conditioner. Based on the current study condition, the heat pump air conditioner which has a air/family waste water multiple heat source is preliminary designed. The working cycle and characteristics of the air conditioner are analyzed by using the thermodynamic principle. The results show that the refrigeration performance of the heat pump air conditioner is better than that of air source heat pump air conditioner, the heating performance and the situation which the outdoor heat exchanger frosts are improved.%提出将空气-水作为热泵型空调器的复合热源.根据当前的研究状况,初步设计空气-水复合热源热泵型空调器,利用热力学原理分析该空调器的工作循环和特点,结果表明该空调器的制冷性能高于空气源热泵空调器,制热和室外换热器结霜状况得到一定改善.

  13. Neutron generator for BNCT based on high current ECR ion source with gyrotron plasma heating.

    Science.gov (United States)

    Skalyga, V; Izotov, I; Golubev, S; Razin, S; Sidorov, A; Maslennikova, A; Volovecky, A; Kalvas, T; Koivisto, H; Tarvainen, O

    2015-12-01

    BNCT development nowadays is constrained by a progress in neutron sources design. Creation of a cheap and compact intense neutron source would significantly simplify trial treatments avoiding use of expensive and complicated nuclear reactors and accelerators. D-D or D-T neutron generator is one of alternative types of such sources for. A so-called high current quasi-gasdynamic ECR ion source with plasma heating by millimeter wave gyrotron radiation is suggested to be used in a scheme of D-D neutron generator in the present work. Ion source of that type was developed in the Institute of Applied Physics of Russian Academy of Sciences (Nizhny Novgorod, Russia). It can produce deuteron ion beams with current density up to 700-800 mA/cm(2). Generation of the neutron flux with density at the level of 7-8·10(10) s(-1) cm(-2) at the target surface could be obtained in case of TiD2 target bombardment with deuteron beam accelerated to 100 keV. Estimations show that it is enough for formation of epithermal neutron flux with density higher than 10(9) s(-1) cm(-2) suitable for BNCT. Important advantage of described approach is absence of Tritium in the scheme. First experiments performed in pulsed regime with 300 mA, 45 kV deuteron beam directed to D2O target demonstrated 10(9) s(-1) neutron flux. This value corresponds to theoretical estimations and proofs prospects of neutron generator development based on high current quasi-gasdynamic ECR ion source.

  14. Errors in Thermographic Camera Measurement Caused by Known Heat Sources and Depth Based Correction

    Directory of Open Access Journals (Sweden)

    Mark Christian E. Manuel

    2016-03-01

    Full Text Available Thermal imaging has shown to be a better tool for the quantitative measurement of temperature than single spot infrared thermometers. However, thermographic cameras can encounter errors in acquiring accurate temperature measurements in the presence of other environmental heat sources. Some of these errors arise due to the inability of the thermal camera to detect objects and features in the infrared domain. In this paper, the thermal image is registered as a stereo image from a Kinect system prior to depth-based correction. Experiments demonstrating the error are presented together with the determination of the measurement errors under prior knowledge of the thermographed scene. The proposed correction scheme improves the accuracy of the thermal image through augmentation using the Kinect system.

  15. Curing of a bisphenol E based cyanate ester using magnetic nanoparticles as an internal heat source through induction heating.

    Science.gov (United States)

    Hubbard, Jeremiah W; Orange, François; Guinel, Maxime J-F; Guenthner, Andrew J; Mabry, Joseph M; Sahagun, Christopher M; Rinaldi, Carlos

    2013-11-13

    We report on the control of cyclotrimerization forming a polycyanurate polymer using magnetic iron oxide nanoparticles in an alternating-current (ac) field as an internal heat source, starting from a commercially available monomer. Magnetic nanoparticles were dispersed in the monomer and catalytic system using sonication, and the mixture was subjected to an alternating magnetic field, causing the magnetic nanoparticles to dissipate the energy of the magnetic field in the form of heat. Internal heating of the particle/monomer/catalyst system was sufficient to start and sustain the polymerization reaction, producing a cyanate ester network with conversion that compared favorably to polymerization through heating in a conventional laboratory oven. The two heating methods gave similar differential scanning calorimetry temperature profiles, conversion rates, and glass transition temperatures when using the same temperature profile. The ability of magnetic nanoparticles in an ac field to drive the curing reaction should allow for other reactions forming high-temperature thermosetting polymers and for innovative ways to process such polymers.

  16. Finite element analysis of keyhole plasma arc welding based on an adaptive heat source mode

    Institute of Scientific and Technical Information of China (English)

    Hu Qingxian; Wu Chuansong; Zhang Yuming

    2007-01-01

    An adaptive heat source mode is proposed to account for the keyhole effect and the characteristics of volumetric distribution along the direction of the workpiece thickness. Finite element analysis of the temperature field in keyhole plasma arc welding is conducted and the weld geometry is obtained. The predicted results are in agreement with the measured ones.

  17. Optimal usage of low temperature heat sources to supply district heating by heat pumps

    DEFF Research Database (Denmark)

    Pieper, Henrik; Ommen, Torben Schmidt; Markussen, Wiebke Brix

    2017-01-01

    This paper presents a theoretical study on the optimal usage of different low temperature heat sources to supply district heating by heat pumps. The study is based on data for the Copenhagen region. The heat sources were prioritized based on the coefficient of performance calculated for each hour....... Groundwater, seawater and air heat sources were compared with each other as well as to a scenario consisting of a combination of these heat sources. In addition, base load and peak load units were included. Characteristic parameters were the coefficient of performance, the number of full load hours...

  18. A proposal for a novel H ion source based on electron cyclotron resonance heating and surface ionization

    Energy Technology Data Exchange (ETDEWEB)

    Tarvainen, Ollie A [Los Alamos National Laboratory; Kurennoy, Sergey [Los Alamos National Laboratory

    2008-01-01

    A design for a novel H{sup -} ion source based on electron cyclotron resonance plasma heating and surface ionization is presented. The plasma chamber of the source is an rf-cavity designed for TE{sub 111} eigenmode at 2.45 GHz. The desired mode is excited with a loop antenna. The ionization process takes place on a cesiated surface of a biased converter electrode. The H{sup -} ion beam is further 'self-extracted' through the plasma region. The magnetic field of the source is optimized for plasma generation by electron cyclotron resonance heating, and beam extraction. The design features of the source are discussed in detail and the attainable H{sup -} ion current, beam emittance and duty factor of the novel source are estimated.

  19. A Proposal for a Novel H- Ion Source Based on Electron Cyclotron Resonance Plasma Heating and Surface Ionization

    Science.gov (United States)

    Tarvainen, O.; Kurennoy, S.

    2009-03-01

    A design for a novel H- ion source based on electron cyclotron resonance plasma heating and surface ionization is presented. The plasma chamber of the source is an rf-cavity designed for TE111 eigenmode at 2.45 GHz. The desired mode is excited with a loop antenna. The ionization process takes place on a cesiated surface of a biased converter electrode. The H- ion beam is further "self-extracted" through the plasma region. The magnetic field of the source is optimized for plasma generation by electron cyclotron resonance heating, and beam extraction. The design features of the source are discussed in detail and the attainable H- ion current, beam emittance and duty factor of the novel source are estimated.

  20. Crystallization Analysis and Control of Ammonia-Based Air Source Absorption Heat Pump in Cold Regions

    Directory of Open Access Journals (Sweden)

    Wei Wu

    2013-01-01

    Full Text Available Energy consumption of heating and domestic hot water is very high and will keep increasing. Air source absorption heat pump (ASAHP was proposed to overcome the problems of low energy efficiency and high air pollution existing in boiler systems, as well as the problem of bad performance under low ambient temperatures for electrical heat pumps. In order to investigate the crystallization possibility of ammonia-salt ASAHP, crystallization margin (evaluated by solution mass concentration at generating temperature ranging from 100 to 150°C, evaporating temperature from −30 to 10°C, and condensing temperature from 30 to 65°C are analyzed. To prevent the NH3–NaSCN solution from crystallizing, ASAHP integrated with pressure booster located between the evaporator and absorber is simulated. Analysis and comparisons show that NH3–NaSCN is easy to crystallize at relatively high generating temperature, low evaporating temperature, and low condensing temperature. But crystallization margin of NH3–LiNO3 can always stay above 5% for most conditions, keeping away from crystallization. Pressure booster can effectively avoid the crystallization problem that will take place in the NH3–NaSCN ASAHP system.

  1. Curing of a Bisphenol-E Based Cyanate Ester using Magnetic Nanoparticles as an Internal Heat Source through Induction Heating

    Science.gov (United States)

    2013-11-01

    reported on the effects of layered silicates in LECy based nanocomposites.42 Similarly, the Gu group has investigated the properties of another...temperature, but the sample must be very thin and in most cases the reaction is highly oxygen sensitive. Our use of magnetic nanoparticles in an AC... superconducting quantum interference device (SQUID) magnetometry, thermogravimetric analysis (TGA), and dynamic light scattering (DLS). The particle size was

  2. Multiple source ground heat storage

    Science.gov (United States)

    Belzile, P.; Lamarche, L.; Rousse, D. R.

    2016-09-01

    Sharing geothermal borefields is usually done with each borehole having the same inlet conditions (flow rate, temperature and fluid). The objective of this research is to improve the energy efficiency of shared and hybrid geothermal borefields by segregating heat transfer sources. Two models are briefly presented: The first model allows the segregation of the inlet conditions for each borefields; the second model allows circuits to be defined independently for each leg of double U-tubes in a borehole. An application couples residential heat pumps and arrays of solar collectors. Independent circuits configuration gave the best energy savings in a symmetric configuration, the largest shank spacing and with solar collectors functioning all year long. The boreholes have been shortened from 300 m to 150 m in this configuration.

  3. 30 CFR 57.4500 - Heat sources.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Heat sources. 57.4500 Section 57.4500 Mineral... HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and Control Installation/construction/maintenance § 57.4500 Heat sources. Heat sources capable of producing...

  4. 30 CFR 56.4500 - Heat sources.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Heat sources. 56.4500 Section 56.4500 Mineral... HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Fire Prevention and Control Installation/construction/maintenance § 56.4500 Heat sources. Heat sources capable of producing...

  5. Performance analysis of a soil-based thermal energy storage system using solar-driven air-source heat pump for Danish buildings sector

    DEFF Research Database (Denmark)

    Jradi, M.; Veje, C.; Jørgensen, B. N.

    2017-01-01

    source. Employing a PV system of 30 kW capacity, it was found that a storage medium of 900 m3 of soil is capable of providing the heating needs for a housing project of 1000 m2 internal floor area. The year round transient behaviour of the thermal energy storage medium is reported in addition to the heat...... and evaluation of the performance of an underground soil-based thermal energy storage system for solar energy storage, coupled with a combined heat and power generation system. A combined PV-Air Source Heat Pump (ASHP) system is utilized to fulfil heating and electricity needs of a housing project in Odense.......2% for the combined PV-ASHP system employing a seasonal underground thermal energy storage block....

  6. Control of heat source in a heat conduction problem

    Science.gov (United States)

    Lyashenko, V.; Kobilskaya, E.

    2014-11-01

    The mathematical model of thermal processes during the heat treatment of a moving axisymmetric environment, for example wire. is considered. The wire is heated by internal constantly or periodically operating heat source. It is presented in the form of initial-boundary value problem for the unsteady heat equation with internal constantly or periodically operating heat source. The purpose of the work is the definition of control parameter of temperature field of a moving area, which is heated by internal heat source. The control parameters are determined by solving a nonlocal problem for the heat equation. The problem of getting an adequate temperature distribution throughout the heating area is considered. Therefore, a problem of heat source control is solved, in particular, control by electric current. Control of the heat source allows to maintain the necessary, from a technological point of view, temperature in the heating area. In this paper, to find additional information about the source of heat. The integral condition is used in the control problem. Integral condition, which is considered in the work, determines the energy balance of the heating zone and connects the desired temperature distribution in the internal points of area with temperatures at the boundaries. Control quality in an extremum formulation of the problem is assessed using the quadratic functional. In function space, from a physical point of view, proposed functional is the absolute difference between the actual emission of energy and absorbed energy in the heating zone. The absorbed energy is calculated by solving of the boundary value problem. Methods of determining the control parameters of temperature field are proposed. The resulting problem is solved by iterative methods. At different physical conditions, numerical calculations are carried out, control parameters of the heat treatment process are obtained.

  7. Irreversible three-heat-source refrigerator with heat transfer law of Q{alpha}{delta}(T{sup -1}) and its performance optimization based on ECOP criterion

    Energy Technology Data Exchange (ETDEWEB)

    Ngouateu Wouagfack, Paiguy Armand [University of Dschang, L2MSP, Department of Physics, PO Box 67, Dschang (Cameroon); Tchinda, Rene [University of Dschang, LISIE, University Institute of Technology Fotso Victor, PO Box 134, Bandjoun (Cameroon)

    2011-11-15

    The new thermo-ecological optimization of an absorption system for cooling applications operating between three temperature levels with the linear phenomenological heat transfer law of Q{alpha}{delta}(T{sup -} {sup 1}) has been performed by taking account the losses of heat resistance, internal irreversibility and leakage. The considered objective function is the ecological coefficient of performance (ECOP) and is defined as the cooling load per unit loss rate of availability. The comparative analysis with the ecological optimization criterion (E) defined in the literature and also with the cooling load optimization criterion (R) has been carried out to prove the utility of the new thermo-ecological optimization criterion (ECOP) for three-heat-source refrigerators with linear phenomenological heat transfer law. The results show that the three-heat-source refrigeration cycle working at maximum ECOP conditions has a significant advantage in terms of entropy production rate and coefficient of performance over the maximum E and maximum R conditions. The obtained results may provide a general theoretical tool for the thermo-ecological design of absorption refrigerator. (orig.)

  8. Construction and realization of the knowledge base and inference engine of an IDSS model for air-conditioning cooling/heating sources selection

    Institute of Scientific and Technical Information of China (English)

    LiuYing; WangRuzhu; LiYunfei; ZhangXiaosong

    2003-01-01

    The knowledge representation mode and inference control strategy were analyzed according to the specialties of air-conditioning cooling/heating sources selection. The constructing idea and working procedure for knowledge base and inference engine were proposed while the realization technique of the C language was discussed. An intelligent decision support system (IDSS) model based on such knowledge representation and inference mechanism was developed by domain engineers. The model was verified to have a small kernel and powerful capability in list processing and data driving, which was successfully used in the design of a cooling/heating sources system for a large-sized office building.

  9. Similarity of Heat Transfer on Heat Source Elements in the Entrance Region in Electronic Equipment

    Institute of Scientific and Technical Information of China (English)

    Jane Z. Jiang; Sui Lin

    2001-01-01

    A similarity equation for heat transfer on heat source elements situated in the entrance region in electronic equipment is developed based on the experimental data obtained by Sparrow et al.[4]. The characteristic of the similarity equation is that the ratio of the heat transfer coefficient at the entrance region to that at the fully developed region is independent of the Reynolds number. It depends only on the row number of the elements situated in the entrance region. An example of the usefulness of the similarity equation is presented that determines the heat transfer on heat source elements in a power unit that contains only a small number of the heat source elements.

  10. Mapping of low temperature heat sources in Denmark

    DEFF Research Database (Denmark)

    Bühler, Fabian; Holm, Fridolin Müller; Huang, Baijia

    2015-01-01

    of those heat sources feasible. In this work a mapping of those heat sources is performed to gain an overview of the potential amount of waste heat and natural heat sources in Denmark. The energy potentials are mapped together with the temperature ranges at which the heat is available and the exergy...... content of the heat. The mapping is based on data and literature primarily published by Statistics Denmark and the Danish Energy Agency, as well as interviews with specialists and engineering estimates. The results indicate that up to 13 % of the energy input to the analysed sectors is available as waste...... and deep geothermal energy. The theoretical solar thermal potential alone would be above 500 PJ per year. For the development of advanced thermodynamic cycles for the integration of heat sources in the Danish energy system, several areas of interest are determined. In the maritime transport sector a high...

  11. Heat transfer interface between a high temperature heat source and a heat sink

    Energy Technology Data Exchange (ETDEWEB)

    du Pre, F.K.; Jaspers, H.A.

    1977-10-11

    A heat-transfer interface between and separating a high temperature heat source and a heat sink is formed by the adjacent walls of the heat source and heat sink with a thin gap between these walls and helium gas sealed in the gap, the walls preferably defining concentric hemispheres; this interface being particularly feasible as separable walls of the heater portion of a Stirling engine and a heat source.

  12. The mechanical measuring method of welding heat source efficiency

    Institute of Scientific and Technical Information of China (English)

    Zhang Jianqiang; Zhang Guodong; He Jie; Wang Chengquan; Chen Bingquan

    2007-01-01

    Based on the principle of residual deformation induced by superposition of the welding residual stress and working stress, the welding heat source efficiency has been determined by measuring displacement changes of specimens under loading and unloading in tensile tests, and combining with calculating welding parameters. Meanwhile, the welding heat source efficiencies obtained are compared with those of the measuring-calculating method. The research results show that the welding heat source efficiencies are almost the same as those obtained by the measuring-calculating method. Therefore, the welding heat source efficiency can be determined accurately by this method, and a new determining method of the heat source efficiency for the welding heat process calculating has been provided.

  13. Microflares as Possible Sources for Coronal Heating

    Indian Academy of Sciences (India)

    Meera Gupta; Rajmal Jain; Jayshree Trivedi; A. P. Mishra

    2008-03-01

    We present a preliminary study of 27 microflares observed by Solar X-ray Spectrometer (SOXS) mission during July 2003 to August 2006. We found that all 27 microflares show the Fe-line feature peaking around 6.7 keV, which is an indicator of the presence of coronal plasma temperature ≥ 9 MK. On the other hand, the spectra of microflares showhybrid model of thermal and non-thermal emission, which further supports them as possible sources of coronal heating. Our results based on the analysis show that the energy relapsed by the microflares is good enough for heating of the active corona. We discuss our results in the light of the hybrid model of microflares production.

  14. Simulation-based assessment of the viability of future heat and power sources for the UK domestic sector

    Energy Technology Data Exchange (ETDEWEB)

    Kelly, N. [Strathclyde Univ., Glasgow, Scotland (United Kingdom). Energy Systems Research Unit

    2005-07-01

    Changes in the way energy is supplied, including fuel mix substitution and more heat and power production from nuclear power or renewable energy sources, will be required in order for the United Kingdom to reach its target of a 60 per cent reduction in greenhouse gas emissions by 2050 compared to 1990 values. Changes will also be required in energy supply, including improvement in energy efficiency and the use of micro heat and power technologies such as photovoltaics (PV), fuel cells, micro wind power, micro-combined heat and power (CHP) and heat pumps. These technologies are cited as one means of reducing carbon dioxide (CO{sub 2}) emissions. The domestic sector, driven by human health needs and the development of energy efficient buildings, can have a significant impact on energy use. Simulation can play an important role in analyzing the impact of such issues. This paper discussed the use of modeling in assessing the demand for heat and power coupled with the performance of local energy supply systems and quantifying any resulting environmental benefits. Simulation can evaluate whether micro-generation will produce environmental savings, given the likely increase in production of electricity from centralized renewable sources such as wind and tidal power. It can also evaluate the levels of efficiency required to produced the savings and whether they are feasible. The performance of the 4 different technologies was analyzed using simulation to find minimum thermodynamic performance criteria required to produce environmental and economic advantages over conventional domestic energy supplies. It was noted the study provides insight into the fundamental viability of each of the 4 technologies but more work is required on energy storage and more complex control strategies before drawing final conclusions. A fixed CO{sub 2} emissions coefficient was assumed in this paper, but in reality, this will vary over time as different central power sources come on and off line

  15. Design of serially connected district heating heat pumps utilising a geothermal heat source

    DEFF Research Database (Denmark)

    Jensen, Jonas Kjær; Ommen, Torben Schmidt; Markussen, Wiebke Brix

    2017-01-01

    The design of two heat pumps (HP), connected in series, was investigated for operation in the district heating (DH) network of the Greater Copenhagen area, Denmark. The installation was dimensioned to supply 7.2 MW of heat at a temperature of 85 °C. The heat pumps utilise a geothermal heat source...

  16. Advanced radioisotope heat source for Stirling Engines

    Science.gov (United States)

    Dobry, T. J.; Walberg, G.

    2001-02-01

    The heat exchanger on a Stirling Engine requires a thermal energy transfer from a heat source to the engine through a very limited area on the heater head circumference. Designing an effective means to assure maximum transfer efficiency is challenging. A single General Purpose Heat Source (GPHS), which has been qualified for space operations, would satisfy thermal requirements for a single Stirling Engine that would produce 55 electrical watts. However, it is not efficient to transfer its thermal energy to the engine heat exchanger from its rectangular geometry. This paper describes a conceptual design of a heat source to improve energy transfer for Stirling Engines that may be deployed to power instrumentation on space missions. .

  17. Optimal Ground Source Heat Pump System Design

    Energy Technology Data Exchange (ETDEWEB)

    Ozbek, Metin [ENVIRON; Yavuzturk, Cy [University of Hartford; Pinder, George [University of Vermont

    2015-04-15

    Despite the facts that GSHPs first gained popularity as early as the 1940’s and they can achieve 30 to 60 percent in energy savings and carbon emission reductions relative to conventional HVAC systems, the use of geothermal energy in the U.S. has been less than 1 percent of the total energy consumption. The key barriers preventing this technically-mature technology from reaching its full commercial potential have been its high installation cost and limited consumer knowledge and trust in GSHP systems to deliver the technology in a cost-effective manner in the market place. Led by ENVIRON, with support from University Hartford and University of Vermont, the team developed and tested a software-based a decision making tool (‘OptGSHP’) for the least-cost design of ground-source heat pump (‘GSHP’) systems. OptGSHP combines state of the art optimization algorithms with GSHP-specific HVAC and groundwater flow and heat transport simulation. The particular strength of OptGSHP is in integrating heat transport due to groundwater flow into the design, which most of the GSHP designs do not get credit for and therefore are overdesigned.

  18. Optimal Ground Source Heat Pump System Design

    Energy Technology Data Exchange (ETDEWEB)

    Ozbek, Metin [Environ Holdings Inc., Princeton, NJ (United States); Yavuzturk, Cy [Univ. of Hartford, West Hartford, CT (United States); Pinder, George [Univ. of Vermont, Burlington, VT (United States)

    2015-04-01

    Despite the facts that GSHPs first gained popularity as early as the 1940’s and they can achieve 30 to 60 percent in energy savings and carbon emission reductions relative to conventional HVAC systems, the use of geothermal energy in the U.S. has been less than 1 percent of the total energy consumption. The key barriers preventing this technically-mature technology from reaching its full commercial potential have been its high installation cost and limited consumer knowledge and trust in GSHP systems to deliver the technology in a cost-effective manner in the market place. Led by ENVIRON, with support from University Hartford and University of Vermont, the team developed and tested a software-based a decision making tool (‘OptGSHP’) for the least-cost design of ground-source heat pump (‘GSHP’) systems. OptGSHP combines state of the art optimization algorithms with GSHP-specific HVAC and groundwater flow and heat transport simulation. The particular strength of OptGSHP is in integrating heat transport due to groundwater flow into the design, which most of the GSHP designs do not get credit for and therefore are overdesigned.

  19. Earth's Heat Source - The Sun

    CERN Document Server

    Manuel, Oliver K

    2009-01-01

    The Sun encompasses planet Earth, supplies the heat that warms it, and even shakes it. The United Nation Intergovernmental Panel on Climate Change (IPCC) assumed that solar influence on our climate is limited to changes in solar irradiance and adopted the consensus opinion of a Hydrogen-filled Sun, the Standard Solar Model (SSM). They did not consider the alternative solar model and instead adopted another consensus opinion: Anthropogenic greenhouse gases play a dominant role in climate change. The SSM fails to explain the solar wind, solar cycles, and the empirical link of solar surface activity with Earth changing climate. The alternative solar model, that was molded from an embarrassingly large number of unexpected observations revealed by space-age measurements since 1959, explains not only these puzzles but also how closely linked interactions between the Sun and its planets and other celestial bodies induce turbulent cycles of secondary solar characteristics that significantly affect Earth climate.

  20. Lunar Base Heat Pump

    Science.gov (United States)

    Walker, D.; Fischbach, D.; Tetreault, R.

    1996-01-01

    The objective of this project was to investigate the feasibility of constructing a heat pump suitable for use as a heat rejection device in applications such as a lunar base. In this situation, direct heat rejection through the use of radiators is not possible at a temperature suitable for lde support systems. Initial analysis of a heat pump of this type called for a temperature lift of approximately 378 deg. K, which is considerably higher than is commonly called for in HVAC and refrigeration applications where heat pumps are most often employed. Also because of the variation of the rejection temperature (from 100 to 381 deg. K), extreme flexibility in the configuration and operation of the heat pump is required. A three-stage compression cycle using a refrigerant such as CFC-11 or HCFC-123 was formulated with operation possible with one, two or three stages of compression. Also, to meet the redundancy requirements, compression was divided up over multiple compressors in each stage. A control scheme was devised that allowed these multiple compressors to be operated as required so that the heat pump could perform with variable heat loads and rejection conditions. A prototype heat pump was designed and constructed to investigate the key elements of the high-lift heat pump concept. Control software was written and implemented in the prototype to allow fully automatic operation. The heat pump was capable of operation over a wide range of rejection temperatures and cooling loads, while maintaining cooling water temperature well within the required specification of 40 deg. C +/- 1.7 deg. C. This performance was verified through testing.

  1. Characterization and modeling of the heat source

    Energy Technology Data Exchange (ETDEWEB)

    Glickstein, S.S.; Friedman, E.

    1993-10-01

    A description of the input energy source is basic to any numerical modeling formulation designed to predict the outcome of the welding process. The source is fundamental and unique to each joining process. The resultant output of any numerical model will be affected by the initial description of both the magnitude and distribution of the input energy of the heat source. Thus, calculated weld shape, residual stresses, weld distortion, cooling rates, metallurgical structure, material changes due to excessive temperatures and potential weld defects are all influenced by the initial characterization of the heat source. Understandings of both the physics and the mathematical formulation of these sources are essential for describing the input energy distribution. This section provides a brief review of the physical phenomena that influence the input energy distributions and discusses several different models of heat sources that have been used in simulating arc welding, high energy density welding and resistance welding processes. Both simplified and detailed models of the heat source are discussed.

  2. Geothermal source heat pump performance for a greenhouse heating system: an experimental study

    Directory of Open Access Journals (Sweden)

    Alexandros Sotirios Anifantis

    2016-09-01

    Full Text Available Greenhouses play a significant function in the modern agriculture economy even if require great amount of energy for heating systems. An interesting solution to alleviate the energy costs and environmental problems may be represented by the use of geothermal energy. The aim of this paper, based on measured experimental data, such as the inside greenhouse temperature and the heat pump performance (input and output temperatures of the working fluid, electric consumption, was the evaluation of the suitability of low enthalpy geothermal heat sources for agricultural needs such as greenhouses heating. The study was carried out at the experimental farm of the University of Bari, where a greenhouse was arranged with a heating system connected to a ground-source heat pump (GSHP, which had to cover the thermal energy request. The experimental results of this survey highlight the capability of the geothermal heat source to ensue thermal conditions suitable for cultivation in greenhouses even if the compressor inside the heat pump have operated continuously in a fluctuating state without ever reaching the steady condition. Probably, to increase the performance of the heat pump and then its coefficient of performance within GSHP systems for heating greenhouses, it is important to analyse and maximise the power conductivity of the greenhouse heating system, before to design an expensive borehole ground exchanger. Nevertheless, according to the experimental data obtained, the GSHP systems are effective, efficient and environmental friendly and may be useful to supply the heating energy demand of greenhouses.

  3. Ground as a possible heat pump source

    Energy Technology Data Exchange (ETDEWEB)

    Lazzarin, R. [Padova Univ. (Germany). Dipt. di Tecnica e Gestione die Istemi Industriali

    2001-06-01

    Heat pumps are devices that can increase the thermal level of heat taken from an available source. Their performances are usually very sensible to the temperatures. This is the reason why sources different from the outside air are welcome, since that source is thermally unfavourable. The ground is a possible very favourable source: temperature variations are damped in the ground so much the more deeper one descends. The variations are also delayed, so that in the coldest period one can find equality very good thermal levels. The two main used systems are: horizontal tubes at a depth between 0.8 and 1.5m and vertical tubes. This last technology has gained an increasing popularity with depths which are sometimes deeper than 100m. It interests a large volume of ground with a comparatively small surface area. It is a technology already widespread in Switzerland (where more than 15.000 ground heat pumps were installed in these years), Germany and Austria. It could be a very favourable technology also in Italy and other mediterranean countries both for the presence of good thermal levels underground with excellent characteristics of heat exchange and for the possible use of the ground as a suitable summer thermal sink. (orig.)

  4. Monitoring actual performance of ground source heat pump system using GPRS-based data transmission:A case analysis in Tangshan

    Institute of Scientific and Technical Information of China (English)

    杜红普; 孔祥飞; 李敏; 齐承英

    2015-01-01

    The energy efficiency monitoring is an essential precondition for ground source heat pump system’s controlling and energy saving operation. Based on the data monitoring applied in the school building, this work is focused on the parameters acquisition and operation analysis of the GSHP system in Tangshan. Results show the average COPs (coefficient of performance) are 2.85 and 2.70 in summer and winter, respectively, and heat(cold) unbalance underground existed after whole year operation. The analysis of data also indicates that the direct borehole air-conditioning saved some power consumption obviously in the early stage of summer and energy saving of the GSHP system depended remarkably on its operation and management level. Besides the observation points of ground temperature are laid for a large-scale GSHP system, and the hydraulic balance of the pipes group needs to be concerned specially in safeguarding better reliability.

  5. MODEL OF LASER-TIG HYBRID WELDING HEAT SOURCE

    Institute of Scientific and Technical Information of China (English)

    Chen Yanbin; Li Liqun; Feng Xiaosong; Fang Junfei

    2004-01-01

    The welding mechanism of laser-TIG hybrid welding process is analyzed. With the variation of arc current, the welding process is divided into two patterns: deep-penetration welding and heat conductive welding. The heat flow model of hybrid welding is presented. As to deep-penetration welding, the heat source includes a surface heat flux and a volume heat flux. The heat source of heat conductive welding is composed of two Gaussian distribute surface heat sources. With this heat source model, a temperature field is calculated. The finite element code MARC is employed for this purpose. The calculation results show a good agreement with the experimental data.

  6. Ion plating with an induction heating source

    Science.gov (United States)

    Spalvins, T.; Brainard, W. A.

    1976-01-01

    Induction heating is introduced as an evaporation heat source in ion plating. A bare induction coil without shielding can be directly used in the glow discharge region with no arcing. The only requirement is to utilize an rf inductive generator with low operating frequency of 75 kHz. Mechanical simplicity of the ion plating apparatus and ease of operation is a great asset for industrial applications; practically any metal such as nickel, iron, and the high temperature refractories can be evaporated and ion plated.

  7. Some comments on air source heat pumps

    Energy Technology Data Exchange (ETDEWEB)

    Haukaas, H.T. (Norges tekniska hoegskola, Trondheim (Norway)). Institutt for kuldeteknikk

    1982-02-01

    Some vital conditions regarding air/water heat pumps are analyzed by use of computer simulators of a middle sized heat pump system. Heat pumps, and specially air source units, should always be used in combination with conventional heating equipment for peak load supply. (Bivalent systems). The economic optimum heat pump capacity compared to system design load is strongly related to the climate. At typical coastal conditions a ratio of 60-70 per cent is found favourable, while 40-50 per cent will be the correct choice for Norwegian inland area. Analysis of the evaporator shows that it should be designed for 120-130 W/m/sup 2/ specific load and 2-2.2 m/s inlet air velocity, which is well below common practice in designing standard air coolers. The condenser LMTD (logaritmic mean temperature difference) should be chosen about 4 degrees C, while the corresponding 'sellers optimum' is calculated to app. 8.5 degrees C. The difference in total heating costs between systems fully designed according to 'sellers optimum' and 'buyers optimum' respectively is found to be about 0.01 Nkr/kWh.

  8. Research on ground heat exchanger of Ground Source Heat Pump technique

    Institute of Scientific and Technical Information of China (English)

    LIU Dong-sheng; SUN You-hong; GAO Ke; WU Xiao-hang

    2004-01-01

    Ground Source Heat Pump technique and its operating principle are described in this paper. Ground heat exchanger is the key technique of ground source heat pump and its pattems are discussed. Software is helpful to design ground heat exchanger. A project of Chinese Ground Source Heat Pump is introduced and its market is more and more extensive.

  9. Carbon footprint of ground source heat pump system in heating solar greenhouse based on life cycle assessment%日光温室地源热泵供暖碳足迹的生命周期分析

    Institute of Scientific and Technical Information of China (English)

    柴立龙; 马承伟; 刘明池; 王宝驹; 武占会; 许勇

    2014-01-01

    The Chinese solar greenhouse, characterized by east-west orientation, a transparent camber south roof, and a solid north roof and east and west walls, is utilized primarily in horticulture in northern China. This design of greenhouse can keep the sheltering plants from freezing in winter because of the“greenhouse effect”. However, the healthy growing of plants still needs assisted heating especially during winter nights. The coal-fired heating system (CFHs) and the natural gas-fired heating system (GFHs) both have been widely applied to heat greenhouses. However, the conventional fossil energy sources, such as coal and natural gas, are non-renewable and are the major greenhouse gas (GHG) contributors. The overusing of fossil fuel in agricultural production has been directly or indirectly related to the global climate change, environmental pollution, and energy crisis. Therefore, renewable and clean energy, such as solar, geothermal, and shallow geothermal has been increasingly applied for greenhouse heating or cooling across the world. Ground source heat pump (GSHP) technology has dual functions in heating and cooling. It is one of the most rapidly growing green technologies for heating and air-conditioning in recent years. The GSHP application for solar greenhouse heating has proven to have a high primary energy ratio or coefficient of performance (COP) in previously studies. However, the environmental performance of the GSHP in heating solar greenhouse, such as its carbon footprint, is still unknown. Systematic and long-term study of the specific GSHP greenhouse-heating was required to evaluate its carbon footprint based on life cycle assessment (LCA) method. The GSHP in a Chinese solar greenhouse was studied to evaluate its environmental performance in greenhouse heating. The environmental performance of the GSHP was analyzed based on the field test data and the performance analysis models that were developed in this study. According to the study, in a 480 m

  10. Accommodation Mode of Wind Power Based on Water Source Heat Pump Technology%基于水源热泵技术的风电消纳模式

    Institute of Scientific and Technical Information of China (English)

    李群英; 冯利民; 许宇辉; 李春亮; 王绍然

    2012-01-01

    Based on the water source heat pump technology,a novel mode on wind power accommodation is proposed.The principle of this mode is analyzed firstly,its impacts on the improvement of the wind power accommodation,the promotion of energy-saving and emission-reduction,the improvement of city heat supply and the economic enhancement of the electrical generation enterprises are studied.With the proposed mode,the residual heat of the circulating water in the heat-engine plants can be recycled to improve the quality of city heat supply,the stability of the heat supply network and the capacity of wind power accommodation in the power grid,and reduce carbon emission during the process of electric power generation.The economic,social,environmental benefits and its application prospect are verified by the research data.%提出了基于水源热泵技术的风电消纳模式。分析了该模式的原理,研究了其在增加风电消纳、促进节能减排、改善城市供热及提高发电企业经济效益等方面的作用。研究表明,通过该模式,可将火力发电厂冷却循环水中的低品位余热转变为有用热能进行城市供暖,提高城市集中供热的质量和稳定性,同时还能够显著增加电网风电消纳能力,并有利于减少电能生产过程中的污染物排放。分析表明,该模式具有良好的经济、社会与环境效益,具备良好的发展前景。

  11. Utilization of low-temperature heat sources for heat and power production

    DEFF Research Database (Denmark)

    Haglind, Fredrik; Elmegaard, Brian

    2014-01-01

    Low-temperature heat sources are available in many applications, ranging from waste heat from marine diesel engines, industries and refrigeration plants to biomass, geothermal and solar heat sources. There is a great potential for enhancing the utilization of these heat sources by novel thermodyn......Low-temperature heat sources are available in many applications, ranging from waste heat from marine diesel engines, industries and refrigeration plants to biomass, geothermal and solar heat sources. There is a great potential for enhancing the utilization of these heat sources by novel.......Both power production and heat pumps may benefit from the development as both technologies utilize a heat source. This makes it possible to cover the complete temperature range of low temperature sources. The development may contribute to significantly lower energy consumption in Danish industry and shipping...

  12. Reflection of ground-source heat pump systems' application

    Institute of Scientific and Technical Information of China (English)

    ZHANGSuyun; LINZhenguo; WUXiangsheng; WUTian

    2003-01-01

    Ground-source heat pump system is an air-conditioning form of energy efficient and environment protection. This article introduced the forms of ground-source heat pump systems, analyzed the problems of ground-source heat pump systems in application in China, and put forward the solutions to these problems.

  13. Development of a Portable Thermogenerator for Uncontrolled Heat Sources

    Science.gov (United States)

    Juanicó, Luis E.; Rinalde, Fabián; Taglialavore, Eduardo; Molina, Marcelo

    2013-07-01

    This paper presents the development of a portable thermogenerator designed to work on uncontrolled heat sources. Its thermal behavior regarding both steady-state and transient regimens was analytically described and numerically solved by using a lumped capacity model. The ranges of heating power and power increasing rates have been determined to ensure safe operation, or give users advance warning in case of failure. In addition, this model is a useful tool for designing a controller system based on which a feasible thermogenerator can be developed. Experimental tests performed on a prototype based on a commercial BiTe module have demonstrated this goal.

  14. A reference heat source for solar collector thermal testing

    Science.gov (United States)

    Harrison, S. J.; Bernier, M. A.

    1984-12-01

    A direct-comparison reference heat source (RHS), used for testing liquid-based solar collectors, is described. A major advantage of the RHS is its capability to measure the product of mass flow and specific heat directly in the test loop. Calibration tests are performed on two reference heat sources over a range of flowrates and inlet temperatures normally encountered in flat-plate solar collector testing (10 C to 95 C). It is shown that at low flowrates (less than or equal to 0.008 kg/s), localized boiling may introduce errors if the heater power density is not reduced as well, whereas operation at flowrates greater than 0.05 kg/s reduces the temperature rise across the RHS, increasing temperature measurement uncertainty. To achieve satisfactory results with an RHS, a stable inlet temperature, good flowrate control, and regulation of the power supplied to the heater are required.

  15. Operation Performance of Air Source Heat Pump System for Space Heating in Tianjin

    Institute of Scientific and Technical Information of China (English)

    ZHAO Jun; CHEN Yan; QU Hang; LI Xinguo

    2007-01-01

    An air source heat pump system (ASHPS) used in an office building is set up and studied experimentally. Its operating performance in winter is evaluated based on test data and a comparative discussion is given on the effect of climate conditions and heating load ratio on the operation behavior.Then heating capacity variation caused by evaporator frosting is analyzed as well. Finally, the defrosting parameters and the technical feasibility are studied for a constant heating demand. The experimental results indicate that both the outlet water temperature drop and the system COP should be taken into account when setting defrosting parameters, and ASHPS is a viable technology for space heating and hotwater production in winter in Tianjin, which can maintain the room temperature above 19 ℃ when the outdoor temperature is -2 ℃.

  16. Research on modeling of heat source for electron beam welding fusion-solidification zone

    Institute of Scientific and Technical Information of China (English)

    Wang Yajun; Fu Pengfei; Guan Yongjun; Lu Zhijun; Wei Yintao

    2013-01-01

    In this paper,the common heat source model of point and linear heat source in the numerical simulation of electron beam welding (EBW) were summarized and introduced.The combined point-linear heat source model was brought forward and to simulate the welding temperature fields of EBW and predicting the weld shape.The model parameters were put forward and regulated in the combined model,which included the ratio of point heat source to linear heat source Qpr and the distribution of linear heat source Lr.Based on the combined model,the welding temperature fields of EBW were investigated.The results show that the predicted weld shapes are conformable to those of the actual,the temperature fields are reasonable and correct by simulating with combined point-linear heat source model and the typical weld shapes are gained.

  17. Upscaling a district heating system based on biogas cogeneration and heat pumps

    NARCIS (Netherlands)

    van Leeuwen, Richard Pieter; Fink, J.; Smit, Gerardus Johannes Maria; de Wit, Jan B.

    2015-01-01

    The energy supply of the Meppel district Nieuwveense landen is based on biogas cogeneration, district heating, and ground source heat pumps. A centrally located combined heat and power engine (CHP) converts biogas from the municipal wastewater treatment facility into electricity for heat pumps and

  18. Upscaling a district heating system based on biogas cogeneration and heat pumps

    NARCIS (Netherlands)

    Leeuwen, van Richard P.; Fink, Jiří; Wit, de Jan B.; Smit, Gerard J.M.

    2015-01-01

    The energy supply of the Meppel district Nieuwveense landen is based on biogas cogeneration, district heating, and ground source heat pumps. A centrally located combined heat and power engine (CHP) converts biogas from the municipal wastewater treatment facility into electricity for heat pumps and h

  19. Upscaling a district heating system based on biogas cogeneration and heat pumps

    NARCIS (Netherlands)

    van Leeuwen, Richard Pieter; Fink, J.; Smit, Gerardus Johannes Maria; de Wit, Jan B.

    2015-01-01

    The energy supply of the Meppel district Nieuwveense landen is based on biogas cogeneration, district heating, and ground source heat pumps. A centrally located combined heat and power engine (CHP) converts biogas from the municipal wastewater treatment facility into electricity for heat pumps and h

  20. Ground Source Heat Pump in Heating System with Electronics Monitoring

    Directory of Open Access Journals (Sweden)

    NEAMŢU Ovidiu

    2013-10-01

    Full Text Available The monitoring system is implemented for a ground coupled heat pump in heating/ system. The borehole heat exchangers – which are 150 m long - are filled with a mixture of water and ethilene glycol calledbrine. Metering and monitoring energy consumption is achieved for: heat pump, circulation pumps, additional electrical heating, hot air ventilation systems, control systems with sensors: analog and smart sensors. Instantaneous values are stored in a local computer.

  1. The impact of in-canopy wind profile formulations on heat flux estimation in an open orchard using the remote sensing-based two-source model

    Directory of Open Access Journals (Sweden)

    C. Cammalleri

    2010-12-01

    Full Text Available For open orchard and vineyard canopies containing significant fractions of exposed soil (>50%, typical of Mediterranean agricultural regions, the energy balance of the vegetation elements is strongly influenced by heat exchange with the bare soil/substrate. For these agricultural systems a "two-source" approach, where radiation and turbulent exchange between the soil and canopy elements are explicitly modelled, appears to be the only suitable methodology for reliably assessing energy fluxes. In strongly clumped canopies, the effective wind speed profile inside and below the canopy layer can strongly influence the partitioning of energy fluxes between the soil and vegetation components. To assess the impact of in-canopy wind profile on model flux estimates, an analysis of three different formulations is presented, including algorithms from Goudriaan (1977, Massman (1987 and Lalic et al. (2003. The in-canopy wind profile formulations are applied to the thermal-based two-source energy balance (TSEB model developed by Norman et al. (1995 and modified by Kustas and Norman (1999. High resolution airborne remote sensing images, collected over an agricultural area located in the western part of Sicily (Italy comprised primarily of vineyards, olive and citrus orchards, are used to derive all the input parameters needed to apply the TSEB. The images were acquired from June to October 2008 and include a relatively wide range of meteorological and soil moisture conditions. A preliminary sensitivity analysis of the three wind profile algorithms highlights the dependence of wind speed just above the soil/substrate to leaf area index and canopy height over the typical range of canopy properties encountered in these agricultural areas. It is found that differences among the models in wind just above the soil surface are most significant under sparse and medium fractional cover conditions (15–50%. The TSEB model heat flux estimates are compared with micro

  2. Cobalt-60 heat source demonstration program. Phase III. Fabrication. Final report

    Energy Technology Data Exchange (ETDEWEB)

    1973-06-01

    Significant accomplishments completed during Phase III of the /sup 60/Co Heat Source Demonstration program include the following: encapsulation of 2 MCi of /sup 60/Co; fabrication of the heat source, including the ASME coded pressure vessel/core assembly, and biological shielding; endurance testing of a prototype heat pipe for a period of 28 months; fabrication and qualification of the heat pipe emergency cooling subsystem; issue of the safety evaluation report, reference 3, and the operations manual, reference 4; and heat source assembly. The planned demonstration test program was modified to include testing of a total power system. Based on an evaluation of available power conversion systems, which included the closed-cycle Brayton and organic Rankine systems, the closed-cycle Brayton system was selected for use. Selection was based on advantages offered by the direct coupling of this conversion system with the gas-cooled heat source. In implementing the test program, the AiResearch BCD power conversion system was to be coupled to the heat source following initial heat source performance testing and part way through the endurance test. In accordance with the program redirection the following Phase IV checkout operations were completed to evaluate procedural and hardware acceptability: heat source dummy fueling; fueling cask sielding survey; and heat source shielding survey (single pin). Completion of these latter activities verified the acceptability of critical characteristics of the heat source and its supporting equipment.

  3. Desalination using low grade heat sources

    Science.gov (United States)

    Gude, Veera Gnaneswar

    A new, low temperature, energy-efficient and sustainable desalination system has been developed in this research. This system operates under near-vacuum conditions created by exploiting natural means of gravity and barometric pressure head. The system can be driven by low grade heat sources such as solar energy or waste heat streams. Both theoretical and experimental studies were conducted under this research to evaluate and demonstrate the feasibility of the proposed process. Theoretical studies included thermodynamic analysis and process modeling to evaluate the performance of the process using the following alternate energy sources for driving the process: solar thermal energy, solar photovoltaic/thermal energy, geothermal energy, and process waste heat emissions. Experimental studies included prototype scale demonstration of the process using grid power as well as solar photovoltaic/thermal sources. Finally, the feasibility of the process in reclaiming potable-quality water from the effluent of the city wastewater treatment plant was studied. The following results have been obtained from theoretical analysis and modeling: (1) The proposed process can produce up to 8 L/d of freshwater for 1 m2 area of solar collector and evaporation chamber respectively with a specific energy requirement of 3122 kJ for 1 kg of freshwater production. (2) Photovoltaic/thermal (PV/T) energy can produce up to 200 L/d of freshwater with a 25 m2 PV/T module which meets the electricity needs of 21 kWh/d of a typical household as well. This configuration requires a specific energy of 3122 kJ for 1 kg of freshwater production. (3) 100 kg/hr of geothermal water at 60°C as heat source can produce up to 60 L/d of freshwater with a specific energy requirement of 3078 kJ for 1 kg of freshwater production. (4) Waste heat released from an air conditioning system rated at 3.25 kW cooling, can produce up to 125 L/d of freshwater. This configuration requires an additional energy of 208 kJ/kg of

  4. Optimal configuration for a finite high-temperature source heat engine cycle with the complex heat transfer law

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    The optimal configuration of a heat engine operating between a finite high-temperature source and an infinite low-temperature reservoir is derived by using finite time thermodynamics based on a complex heat transfer law,including Newtonian heat transfer law,linear phenomenological heat transfer law,radiative heat transfer law,Dulong-Petit heat transfer law,generalized convective heat transfer law and generalized radiative heat transfer law,q ∝(△T n). In the engine model the only irreversibility of finite rate heat transfer is considered. The optimal relation between the power output and efficiency of the heat engine is also derived by using an equivalent temperature of the hot reservoir. The obtained results include those obtained in recent literature and can provide some theoretical guidance for the designs of practical engines.

  5. Optimal configuration for a finite high-temperature source heat engine cycle with the complex heat transfer law

    Institute of Scientific and Technical Information of China (English)

    LI Jun; CHEN LinGen; SUN FengRui

    2009-01-01

    The optimal configuration of a heat engine operating between a finite high-temperature source and an infinite low-temperature reservoir is derived by using finite time thermodynamics based on a complex heat transfer law, including Newtonian heat transfer law, linear phenomenological heat transfer law, radiative heat transfer law, Dulong-Petit heat transfer law, generalized convective heat transfer law and generalized radiative heat transfer law, q∝ (△Tn). In the engine model the only irreversibility of finite rate heat transfer is considered. The optimal relation between the power output and efficiency of the heat engine is also derived by using an equivalent temperature of the hot reservoir. The obtained re-sults include those obtained in recent literature and can provide some theoretical guidance for the de-signs of practical engines.

  6. AN INVESTIGATION OF THERMAL CHARACTERISTICS OF A SINTERED-WICK HEAT PIPE WITH DOUBLE HEAT SOURCES

    Directory of Open Access Journals (Sweden)

    Nattawut Tharawadee

    2013-01-01

    Full Text Available Heat pipes have been used extensively in the electronic industry for decades especially in laptop computers. For cost-effectiveness, a single heat pipe is designed to simultaneously transfer heat from both the Central Processing Unit (CPU and the Graphics Processing Unit (GPU inside the main board to the heat sink. This causes the efficiency of the heat pipe to change without any theoretical prediction. In this research, thermal performance of a sintered-wick heat pipe with double heat sources has been experimentally and numerically investigated by utilizing the Finite Element Method (FEM. The focus being the effect that the distance between the two heat sources and also the power input pattern (heat source#1 (HT1: heat source#2(HT2 has on temperature and thermal resistance of the heat pipe. The first heat source (HT1 was located at one end and the heat sink was located at another end of the heat pipe, while another heat source (HT2 was placed between HT1 and a heat sink. The ratios of heat input power were controlled at 10W:10W, 20W:10W and 30W:10W. Two copper blocks (15 mm×15 mm were used as heat sources for the evaporator section (Le1, Le2 to electrically supply heat to the bottom half of the heat pipe. A mathematical model using the Finite Element Method (FEM was established to calculate temperature and thermal resistance. The speed of the cooling fan was adjusted to maintain constant operating temperature at the adiabatic section throughout the tests. The operating temperature was controlled at 60 ± 3°C. It was noted that, when distance between the heat sources was increased from 0 mm to 75 mm, thermal resistance slightly decreased from 0.589-0.53°C/W respectively. Heat source 2, therefore, should be placed as close as possible to the condenser section. Both heat sources should have a distance between them of at least 12 mm, which minimizes heat accumulation. When the power input of HT1 was increased from 10 W to 30W (HT2 was

  7. Investigation of the Performance of a Heat Pump Using Waste Water as a Heat Source

    Directory of Open Access Journals (Sweden)

    Ali Kahraman

    2009-08-01

    Full Text Available In this research, a water-water heat pump system using waste water as a heat source, a type that is not often used in Turkey and the World, was experimentally modeled. The experiments were performed under the conditions of simulated waste water temperature values of 20 °C, 30 °C and 40 °C. Inlet and outlet water temperatures of the evaporator and condenser, water flow rates in the evaporator and condenser circuits, pressures at the compressor inlet and outlet and power consumption of the system were measured. The heating coefficients of performance were calculated based on the measurements. It was found that the maximum temperature in the energy storage tank was about 50.6 °C. For the heat source temperatures of 20 °C, 30 °C and 40 °C, the heating coefficients of the performance of the system became 3.36, 3.43 and 3.69, respectively, 6 min. after the start time of the experiments and then they were decreased to 1.87, 1.83 and 1.77 with increasing water temperature in the condenser tank. The mean uncertainty value of the measurement parameters was found to be about ±2.47%. Finally, for the purpose of meeting hot water need as well as floor heating system requirements, it is seen that energy quality level of a waste low grade temperature heat source can be increased by using a heat pump system.

  8. Heat transfer analysis of underground U-type heat exchanger of ground source heat pump system.

    Science.gov (United States)

    Pei, Guihong; Zhang, Liyin

    2016-01-01

    Ground source heat pumps is a building energy conservation technique. The underground buried pipe heat exchanging system of a ground source heat pump (GSHP) is the basis for the normal operation of an entire heat pump system. Computational-fluid-dynamics (CFD) numerical simulation software, ANSYS-FLUENT17.0 have been performed the calculations under the working conditions of a continuous and intermittent operation over 7 days on a GSHP with a single-well, single-U and double-U heat exchanger and the impact of single-U and double-U buried heat pipes on the surrounding rock-soil temperature field and the impact of intermittent operation and continuous operation on the outlet water temperature. The influence on the rock-soil temperature is approximately 13 % higher for the double-U heat exchanger than that of the single-U heat exchanger. The extracted energy of the intermittent operation is 36.44 kw·h higher than that of the continuous mode, although the running time is lower than that of continuous mode, over the course of 7 days. The thermal interference loss and quantity of heat exchanged for unit well depths at steady-state condition of 2.5 De, 3 De, 4 De, 4.5 De, 5 De, 5.5 De and 6 De of sidetube spacing are detailed in this work. The simulation results of seven working conditions are compared. It is recommended that the side-tube spacing of double-U underground pipes shall be greater than or equal to five times of outer diameter (borehole diameter: 180 mm).

  9. Heating a chemical current source which operates at low temperature

    Energy Technology Data Exchange (ETDEWEB)

    Mitsumata, T.; Khosikhara, N.

    1983-02-14

    A chamber for catalytic ignition of hydrogen or gasoline is installed in a chemical current source. The isolated heat heats the chemical current source with a low temperature of the environment providing its optimal operational conditions. The fuel is fed into the chamber from a tank or chamber located in the body of the chemical current source.

  10. Irregular spacing of heat sources for treating hydrocarbon containing formations

    Science.gov (United States)

    Miller, David Scott [Katy, TX; Uwechue, Uzo Philip [Houston, TX

    2012-06-12

    A method for treating a hydrocarbon containing formation includes providing heat input to a first section of the formation from one or more heat sources located in the first section. Fluids are produced from the first section through a production well located at or near the center of the first section. The heat sources are configured such that the average heat input per volume of formation in the first section increases with distance from the production well.

  11. Performance analysis of air——water dual source heat pump water heater with heat recovery

    Institute of Scientific and Technical Information of China (English)

    CHEN ZeShao; TAO WenQuan; ZHU YanWen; HU Peng

    2012-01-01

    A new air-water dual source heat pump water heater with heat recovery is proposed.The heat pump system can heat water by using a single air source,a single water source,or air-water dual sources.The water is first pre-heated by waste hot water,then heated by the heat pump.Waste heat is recovered by first preheating the cold water and as water source of the heat pump.According to the correlated formulas of the coefficient of performance of air-source heat pump and water-source heat pump,and the gain coefficient of heat recovery-preheater,the formulas for the coefficient of performance of heat pump in six operating modes are obtained by using the dimensionless correspondence analysis method.The system characteristics of heat absorption and release associated with the heat recovery-preheater are analyzed at different working conditions.The developed approaches can provide reference for the optimization of the operating modes and parameters.The results of analysis and experiments show that the coefficient of performance of the device can reach 4-5.5 in winter,twice as much as air source heat pump water heater.The utilization of waste heat in the proposed system is higher than that in the system which only uses waste water to preheating or as heat source.Thus,the effect of energy saving of the new system is obvious.On the other hand,the dimensionless correspondence analysis method is introduced to performance analysis of the heat pump,which also has theoretical significance and practical value.

  12. Convection heat transfer from discrete heat sources in a liquid cooled rectangular channel

    Energy Technology Data Exchange (ETDEWEB)

    Bhowmik, H. [Department of Mechanical Engineering, Dhaka University of Engineering and Technology, Gazipur 1700 (Bangladesh); Tso, C.P. [Faculty of Engineering and Technology, Multimedia University, Jalan Ayer Keroh Lama, 75450 Melaka (Malaysia); Tou, K.W.; Tan, F.L. [School of Mechanical and Production Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798 (Singapore)

    2005-11-01

    Steady-state experiments are performed to study general convective heat transfer from an in-line four simulated electronic chips in a vertical rectangular channel using water as the working fluid. The experimental data covers a wide range for laminar flow under natural, mixed and forced convection conditions with Reynolds number based on channel hydraulic diameter ranging from 40 to 2220 and Reynolds number based on heat source length ranging from 50 to 2775, respectively. The heat flux ranges from 0.1W/cm{sup 2} to 0.6W/cm{sup 2}. The inlet water temperature is at 24{sup o}C. The effect of heat fluxes, flow rates and geometrical parameters such as chip number are investigated. The experimental results indicate that the heat transfer coefficient is strongly affected by Reynolds number and fully-developed values of heat transfer coefficient are reached before the first chip. Empirical correlations are developed for relations using Nusselt number, Reynolds number and Grashof number, based on channel hydraulic diameter. (author)

  13. Optimal configuration for a finite low-temperature source refrigerator cycle with heat transfer law

    Directory of Open Access Journals (Sweden)

    Jun Li, Lingen Chen, Yanlin Ge, Fengrui Sun

    2016-01-01

    Full Text Available The optimal configuration of a refrigeration cycle operating between a finite low-temperature source and an infinite high-temperature sink are derived by using finite time thermodynamics based on a complex heat transfer law, including Newtonian heat transfer law, linear phenomenological heat transfer law, radiative heat transfer law, Dulong-Petit heat transfer law, generalized convective heat transfer law and generalized radiative heat transfer law. In the refrigeration cycle model the only irreversibility of finite rate heat transfer is considered. The optimal relation between cooling load and coefficient of performance (COP of the refrigeration cycle is also derived by using an equivalent temperature of low-temperature source. The obtained results include those with various heat transfer laws and infinite low-temperature source, and can provide some theoretical guidelines for the designs of practical refrigerators.

  14. Ground-source Heat Pump Barometer

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2011-09-15

    The double whammy dealt by the economic crisis and housing slump has stifled expansion of the ground-source heat pump market in many European countries. The European Union market contracted for the second year running (by 2.9% between 2009 and 2010), and this despite the fact that more than 100,000 units were sold over the twelve-month period, taking the number of installed units past the one million mark. [French] La crise economique ainsi que la crise immobiliere qui touchent de nombreux pays europeens ne facilitent pas l'essor du marche de la pompe a chaleur geothermique. Pour la deuxieme annee consecutive, le marche de l'union europeenne est en baisse (-2,9 % entre 2009 et 2010). il parvient tout de meme a se maintenir au-dessus des 100 000 unites vendues par an, ce qui lui permet de depasser pour la premiere fois le cap du million d'unites installees.

  15. Depth Determination of an Abnormal Heat Source in Biological Tissues

    Institute of Scientific and Technical Information of China (English)

    WANG Qing-Hua; LI Zhen-Hua; LAI Jian-Cheng; HE An-Zhi

    2011-01-01

    We deduce the surface temperature distribution generated by the inner point heat source in biological tissues and propose a graphic method to retrieve the depth of the point heat source. The practical surface temperature distribution can be regarded as the convolution of the temperature distribution of the inner point heat source with the heat source shape function. The depth of an abnormal heat source in biological tissues can be retrieved by using the graphic method combined with the blind deconvolution scheme.%We deduce the surface temperature distribution generated by the inner point heat source in biological tissues and propose a graphic method to retrieve the depth of the point heat source.The practical surface temperature distribution can be regarded as the convolution of the temperature distribution of the inner point heat source with the heat source shape function.The depth of an abnormal heat source in biological tissues can be retrieved by using the graphic method combined with the blind deconvolution scheme.Surface temperature distribution of the biological tissues is closely related to the neighboring metabolic heat production,blood circulation in an organism and environmental temperature.[1] The abnormal metabolic performances of a local region in biological tissue imply malignant changes occurring,which can be distinguished from the variance of surface temperature.Modern development of thermal infrared (TIR) imaging has made the surface temperature measurement of biological tissue easier.Nowadays,several types of tumors,e.g.skin or breast can be recognized with TIR imaging.[2] The diagnostics with TIR imaging require more experienced operators and can not accurately ascertain the site of pathological changes,which limits the value of this technology.Therefore ascertaining the depth of inner heat source in biological body has the extremely important clinical value.

  16. A novel design method for ground source heat pump

    Directory of Open Access Journals (Sweden)

    Dong Xing-Jie

    2014-01-01

    Full Text Available This paper proposes a novel design method for ground source heat pump. The ground source heat pump operation is controllable by using several parameters, such as the total meters of buried pipe, the space between wells, the thermal properties of soil, thermal resistance of the well, the initial temperature of soil, and annual dynamic load. By studying the effect of well number and well space, we conclude that with the increase of the well number, the inlet and outlet water temperatures decrease in summer and increase in winter, which enhance the efficiency of ground source heat pump. The well space slightly affects the water temperatures, but it affects the soil temperature to some extent. Also the ground source heat pump operations matching with cooling tower are investigated to achieve the thermal balance. This method greatly facilitates ground source heat pump design.

  17. Lunar Surface Stirling Power Systems Using Isotope Heat Sources

    Science.gov (United States)

    Schmitz, Paul C.; Penswick, L. Barry; Shaltens, Richard K.

    2010-01-01

    For many years, NASA has used the decay of plutonium-238 (Pu-238) (in the form of the General Purpose Heat Source (GPHS)) as a heat source for Radioisotope Thermoelectric Generators (RTGs), which have provided electrical power for many NASA missions. While RTGs have an impressive reliability record for the missions in which they have been used, their relatively low thermal to electric conversion efficiency and the scarcity of plutonium-238 (Pu-238) has led NASA to consider other power conversion technologies. NASA is considering returning both robotic and human missions to the lunar surface and, because of the long lunar nights (14.75 Earth days), isotope power systems are an attractive candidate to generate electrical power. NASA is currently developing the Advanced Stirling Radioisotope Generator (ASRG) as a candidate higher efficiency power system that produces greater than 160 W with two GPHS modules at the beginning of life (BOL) (32% efficiency). The ASRG uses the same Pu-238 GPHS modules, which are used in RTG, but by coupling them to a Stirling convertor provides a four-fold reduction in the number of GPHS modules. This study considers the use of americium-241 (Am-241) as a substitute for the Pu-238 in Stirling- convertor-based Radioisotope Power Systems (RPS) for power levels from tens of watts to 5 kWe. The Am-241 is used as a substitute for the Pu-238 in GPHS modules. Depending on power level, different Stirling heat input and removal systems are modeled. It was found that substituting Am-241 GPHS modules into the ASRG reduces power output by about one-fifth while maintaining approximately the same system mass. In order to obtain the nominal 160 W of electrical output of the Pu-238 ASRG requires 10 Am-241 GPHS modules. Higher power systems require changing from conductive coupling heat input and removal from the Stirling convertor to either pumped loops or heat pipes. Liquid metal pumped loops are considered as the primary heat transportation on the hot

  18. Study on the Interface Effects Based on Two-Dimensional Green's Functions for the Fluid and Pyroelectric Two-Phase Plane under a Line Heat Source

    Directory of Open Access Journals (Sweden)

    Peng-Fei Hou

    2014-11-01

    Full Text Available Two-dimensional Green's functions for a line heat source applied in the fluid and pyroelectric two-phase plane are presented in this paper. By virtue of the two-dimensional general solutions which are expressed in harmonic functions, six newly introduced harmonic functions with undetermined constants are constructed. Then, all the pyroelectric components in the fluid and pyroelectric two-phase plane can be derived by substituting these harmonic functions into the corresponding general solutions. And the undetermined constants can be obtained by the interface compatibility conditions and the mechanical, electric, and thermal equilibrium conditions. Numerical results are given graphically by contours.

  19. Application of Abaqus to analysis of the temperature field in elements heated by moving heat sources

    Directory of Open Access Journals (Sweden)

    W. Piekarska

    2010-10-01

    Full Text Available Numerical analysis of thermal phenomena occurring during laser beam heating is presented in this paper. Numerical models of surface andvolumetric heat sources were presented and the influence of different laser beam heat source power distribution on temperature field wasanalyzed. Temperature field was obtained by a numerical solution the transient heat transfer equation with activity of inner heat sources using finite element method. Temperature distribution analysis in welded joint was performed in the ABAQUS/Standard solver. The DFLUXsubroutine was used for implementation of the movable welding heat source model. Temperature-depended thermophysical properties for steelwere assumed in computer simulations. Temperature distribution in laser beam surface heated and butt welded plates was numericallyestimated.

  20. Performance analysis on solar-water compound source heat pump for radiant floor heating system

    Institute of Scientific and Technical Information of China (English)

    曲世林; 马飞; 仇安兵

    2009-01-01

    A solar-water compound source heat pump for radiant floor heating (SWHP-RFH) experimental system was introduced and analyzed. The SWHP-RFH system mainly consists of 11.44 m2 vacuum tube solar collector,1 000 L water tank assisted 3 kW electrical heater,a water source heat pump,the radiant floor heating system with cross-linked polyethylene (PE-X) of diameter 20 mm,temperature controller and solar testing system. The SWHP-RFH system was tested from December to February during the heating season in Beijing,China under different operation situations. The test parameters include the outdoor air temperature,solar radiation intensity,indoor air temperature,radiation floor average surface temperature,average surface temperature of the building envelope,the inlet and outlet temperatures of solar collector,the temperature of water tank,the heat medium temperatures of heat pump condenser side and evaporator side,and the power consumption includes the water source heat pump system,the solar source heat pump system,the auxiliary heater and the radiant floor heating systems etc. The experimental results were used to calculate the collector efficiency,heat pump dynamic coefficient of performance (COP),total energy consumption and seasonal heating performance during the heating season. The results indicate that the performance of the compound source heat pump system is better than that of the air source heat pump system. Furthermore,some methods are suggested to improve the thermal performance of each component and the whole SWHP-RFH system.

  1. Heat sources in proton exchange membrane (PEM) fuel cells

    Science.gov (United States)

    Ramousse, Julien; Lottin, Olivier; Didierjean, Sophie; Maillet, Denis

    In order to model accurately heat transfer in PEM fuel cell, a particular attention had to be paid to the assessment of heat sources in the cell. Although the total amount of heat released is easily computed from its voltage, local heat sources quantification and localization are not simple. This paper is thus a discussion about heat sources/sinks distribution in a single cell, for which many bold assumptions are encountered in the literature. The heat sources or sinks under consideration are: (1) half-reactions entropy, (2) electrochemical activation, (3) water sorption/desorption at the GDL/membrane interfaces, (4) Joule effect in the membrane and (5) water phase change in the GDL. A detailed thermodynamic study leads to the conclusion that the anodic half-reaction is exothermic (Δ Sr ev a = - 226 J mo l-1 K-1) , instead of being athermic as supposed in most of the thermal studies. As a consequence, the cathodic half-reaction is endothermic (Δ Sr ev c = + 62.8 J mo l-1 K-1) , which results in a heat sink at the cathode side, proportional to the current. In the same way, depending on the water flux through the membrane, sorption can create a large heat sink at one electrode and an equivalent heat source at the other. Water phase change in the GDL - condensation/evaporation - results in heat sources/sinks that should also be taken into account. All these issues are addressed in order to properly set the basis of heat transfer modeling in the cell.

  2. Adiabatic heating and convection caused by a fixed-heat-flux source in a near-critical fluid.

    Science.gov (United States)

    Soboleva, E B

    2003-10-01

    Dynamics and heat transfer in a near-critical fluid in a square cavity with a finite heat source located at the bottom are studied numerically. A thermally insulated enclosure and a fixed-heat-flux source are considered. The two-dimensional simulation is based on the full Navier-Stokes equations with two-scale splitting of the pressure and the van der Waals equation of state. It is shown that the piston effect is independent of convection. Near the critical point, this effect becomes independent of criticality and convective motions are damped.

  3. On the solution of heat conduction problems involving heat sources via boundary-fitted grids

    Science.gov (United States)

    Grandi, G. M.; Ferreri, J. C.

    1989-01-01

    It is shown that codes employing boundary-fitted grids (BFG) in heat conduction problems involving heat sources must be implemented in strictly numerically conservative form if accurate results are to be obtained. It is demonstrated that, for one-dimensional problems, nonconservative form imply errors originated in grid nonuniformity that cause a spurious increase in the heat source. This in turn leads to significant errors in the computed solution. Therefore, the implementation of BFG codes using nonconservative forms should be avoided. An application to an unsteady, axisymmetric benchmark problem involving a spherical, time-decaying heat source is presented.

  4. Heat pumps using vertical boreholls as heat source; Varmepumper med lodrette boringer som varmeoptager

    Energy Technology Data Exchange (ETDEWEB)

    Pedersen, Svend V. [Teknologisk Institut, Aarhus (Denmark); Thoegersen, L.; Soerensen, Inga [VIA University College, Risskov (Denmark)] [and others

    2013-01-15

    This report presents instructions on what to consider when you have to establish vertical wells as energy sources for ground source heating systems. The report provides an introduction into what to be aware of when it comes to sizing vertical ground hoses as heat absorbers for heat pumps. The initial geological assessments, you have to make are described and there are references to the available tools and websites that exist today. A calculation model is developed for the design of vertical ground hoses. This calculation model is intended as a tool for installers and consultants as well as well drillers. The calculation model contains two computational models, one can be used for initial calculations and dimensioning of vertical ground hoses, and the detailed model can be used for costing by well driller. The simple calculation is based on proven design approach from the German standard VDI 4640, and the detailed calculation is based on a known empirical calculation, which assumes that you know the geology in more detail. In the project measurements were carried out on four installations, and the calculations show that there is good agreement between the measurements and the calculation model. (LN)

  5. Simulation of Velocity and Temperature Distributions of Displacement Ventilation System with Single or Double Heat Sources

    Institute of Scientific and Technical Information of China (English)

    Wenfei Wu; Xuan Wu; Yanhui Feng; Xinxin Zhang

    2007-01-01

    In order to obtain a better understanding of flow characteristics of displacement ventilation, the three-dimensional numerical models are developed using the CFD technology. The numerical simulation results are verified by experiments, based on this, the velocity and temperature distribution of three-dimensional displacement ventilation system with single and double heat sources are studied. Velocity and temperature fields under two different cases of heat source are analyzed and compared. The numerical results show that there are three layers in vertical temperature fields of displacement ventilation system with single or double heat sources, and the vertical temperature distribution of single heat source is different from that of double heat sources. When indoor load is large, the comfort requirement of people indoor can't be satisfied with displacement ventilation system only, thus an additional refrigeration system is necessary. Furthermore, under the condition of two heat sources, the displacement ventilation parameters can't be computed simply according to single heat source inlet parameters, therefore the interaction between heat sources should be considered.

  6. Air Source Cold Climate Heat Pump

    Science.gov (United States)

    2013-08-01

    Unico, Inc. received ISO 9001 :2008 certification. 7.1 COST MODEL The market for CCHP consists includes both residential and light commercial...by electricity that could come from renewable energy. The field demonstration was conducted at the Camp Atterbury Joint Maneuver Training Center...American Society of Heating, Refrigeration, and Air Conditioning Engineers CAJMTC Camp Atterbury Joint Maneuver Training Center CCHP Cold Climate

  7. Heating performance of a ground source heat pump system installed in a school building

    Institute of Scientific and Technical Information of China (English)

    Jaedo; SONG; Kwangho; LEE; Youngman; JEONG; Seongir; CHEONG; Jaekeun; LEE; Yujin; HWANG; Yeongho; LEE; Donghyuk; LEE

    2010-01-01

    The heating performance of a water-to-refrigerant type ground source heat pump system is represented in this paper under the actual working conditions of the GSHP(ground source heat pump) system during the winter season of 2008.Ten heat pump equipments with the capacity of 10 HP each and a closed vertical typed-ground heat exchanger with 24 boreholes of 175 m in depth were constructed.We investigated a variety of working conditions,including the outdoor temperature,the ground temperature,and the water temperature of inlet and outlet of the ground heat exchanger in order to examine the heating performance of the GSHP system.Subsequently,the heating capacity and the input power were investigated to determine the heating performance of the GSHP system.The average heating coefficient of performance(COP) of the heat pump was noted to be 5.1 at partial load of 47%,while the overall system COP was found to be 4.2.Also,performance of the GSHP system was compared with that of air source heat pump.

  8. Oceanic heat sources to Pine Island Bay

    Science.gov (United States)

    Mazloff, M. R.; Gilroy, A. R.; Gille, S. T.; Subramanian, A. C.

    2012-12-01

    The rapid melting of Pine Island Glacier, West Antarctica has been attributed to increased basal melting of its grounded ice-shelf. Recent work suggests that an increased ocean heat supply to Pine Island Bay (PIB) is responsible for this increased melting. There is no consensus, however, on the origin of this increased ocean heat. We use a 2008-2010 state estimate of the Southern Ocean to diagnose the heat budget on the PIB continental shelf. In times of minimal sea-ice coverage, air-sea fluxes dominate the budget. Sea-ice is present over much of the year, however, and on average advection and parameterized small-scale mixing are equally important. The average air-sea fluxes and small scale mixing both act to cool the continental shelf waters, while advection by the large-scale circulation tends to warm these waters. The warmest waters are found on the eastern PIB continental shelf where bathymetric features cause increased advective fluxes and mixing. The average circulation along the PIB continental shelf is eastward consisting of approximately 1 Sv along shelf flow augmented by 1 Sv of across shelf flow to be balanced by a 2 Sv outflow along the eastern PIB shelf. Numerical simulations of passive tracer releases reveal the advective pathways of these waters that reach the continental shelf.

  9. EFFECT OF THE TYPE OF HEAT SOURCES ON CARBON DIOXIDE EMISSIONS

    Directory of Open Access Journals (Sweden)

    Sławomir Rabczak

    2016-11-01

    Full Text Available A lot of attention is nowadays devoted to the problem of generally defined ecology. It is absolutely essential in case of systems and sources generating heat due to their direct influence on the environment through emitting post-process products to the atmosphere which are, most frequently a result of combustion. Therefore, constant searchers are made to optimize the operation of heat sources and to acquire energy from sources for which the general balance of carbon dioxide emission is zero or close to zero. This work compares the emissions of equivalent CO2 from selected systems with the following heat sources: coal, gas furnace, heat pump, and refers results of the analysis to aspects connected with regulations concerning environmental protection. The systems generating thermal energy in the gas furnaces, coal, biomass, as well as the compression heat pumps with the lower heat source as ambient air or ground were taken under consideration, as well as centralized systems for the production of heat based on the combustion of coal, gas, oil, and biomass. the Emission of carbon dioxide for the installation of cogeneration and absorption heat pump were also calculated. Similarly obtained amount of extra emission necessary for the proper operation maintenance of heating devices via the supplied electricity from external source, the mostly fuel-fired power plants for fuels as previously mentioned. The results of the calculations were presented in tables and graphs.

  10. Design of Ground Source Heat Pump Monitoring System Based on MCGS%基于MCGS的地源热泵监控系统的设计

    Institute of Scientific and Technical Information of China (English)

    商家伟; 苏华

    2016-01-01

    A monitoring system is developed for a ground source heat pump system in Chengdu. Equipments are controlled by PLC and monitoring data is transported from PLC to PC. The host PC moni-toring system is developed by MCGS whose functions cover controlling, operation status displaying, data logging and displaying and alarming.%针对成都某别墅地源热泵系统,设计了一个监控系统方案。利用PLC控制空调设备、监测并上传现场数据给上位机。利用MCGS开发上位机监控系统。该监控系统包含设备控制、状态显示、参数采集及显示、报警等功能。

  11. Optimal Hierarchical Decision-Making for Heat Source Selection of District Heating Systems

    Directory of Open Access Journals (Sweden)

    Fang Fang

    2014-01-01

    Full Text Available With the rapid development of China’s urbanization, the proportion between the heating consumption and the energy consumption of the whole society keeps rising in recent years. For a district heating system, the selection of the heat source makes significant impact on the energy efficiency and the pollutant emissions. By integrating the methods of the Analytic Hierarchy Process (AHP and the Preference Ranking Organization Method for Enrichment Evaluation (PROMETHEE, a multiple-attribute decision-making scheme for the heat source selection of district heating systems is proposed in this paper. As a core part of this scheme, a comprehensive benefit index with hierarchical parallel structure is constructed. The economic benefit, environment benefit, and technical benefit can be reflected with a certain percentage in the comprehensive benefit index. To test the efficiency of the proposed scheme, a case study for a large-scale district heating system in Beijing is carried out, where five kinds of heat sources (water source heat pump, ground source heat pump, gas-fired boiler, coal-fired boiler, and oil-fired boiler are taken into account. The analysis and instructions for the final sorting result are also demonstrated.

  12. Evaluation of water source heat pumps for the Juneau, Alaska Area

    Energy Technology Data Exchange (ETDEWEB)

    Jacobsen, J.J.; King, J.C.; Eisenhauer, J.L.; Gibson, C.I.

    1980-07-01

    The purposes of this project were to evaluate the technical and economic feasibility of water source heat pumps (WSHP) for use in Juneau, Alaska and to identify potential demonstration projects to verify their feasibility. Information is included on the design, cost, and availability of heat pumps, possible use of seawater as a heat source, heating costs with WSHP and conventional space heating systems, and life cycle costs for WSHP-based heating systems. The results showed that WSHP's are technically viable in the Juneau area, proper installation and maintenance is imperative to prevent equipment failures, use of WSHP would save fuel oil but increase electric power consumption. Life cycle costs for WSHP's are about 8% above that for electric resistance heating systems, and a field demonstration program to verify these results should be conducted. (LCL)

  13. 基于优属度和层次分析法的冷热源方案优选%Scheme optimization for heat and cold sources based on optimal membership and analytic hierarchy process

    Institute of Scientific and Technical Information of China (English)

    闫加贺; 黄建恩; 冯伟; 张丙利

    2011-01-01

    建立了基于优属度和层次分析法的优选模型,并以海门某办公大楼为实例,对不同的冷热源方案进行优选.结果显示,该模型计算简便,能够达到客观的、科学的优选空调系统冷热源的目的.%The model based on optimal membership and analytic hierarchy process was established. Different heat and cold sources were select for the optimization of central air-conditioning system of a office building in Haimen city. It is proved that the model could optimize the heat and cold sources easy、objectively and scientifically.

  14. Ground Source Integrated Heat Pump (GS-IHP) Development

    Energy Technology Data Exchange (ETDEWEB)

    Baxter, V. D. [ORNL; Rice, K. [ORNL; Murphy, R. [ORNL; Munk, J. [ORNL; Ally, Moonis [ORNL; Shen, Bo [ORNL; Craddick, William [ORNL; Hearn, Shawn A. [ClimateMaster, Inc.

    2013-05-24

    Between October 2008 and May 2013 ORNL and ClimateMaster, Inc. (CM) engaged in a Cooperative Research and Development Agreement (CRADA) to develop a groundsource integrated heat pump (GS-IHP) system for the US residential market. A initial prototype was designed and fabricated, lab-tested, and modeled in TRNSYS (SOLAR Energy Laboratory, et al, 2010) to predict annual performance relative to 1) a baseline suite of equipment meeting minimum efficiency standards in effect in 2006 (combination of air-source heat pump (ASHP) and resistance water heater) and 2) a state-of-the-art (SOA) two-capacity ground-source heat pump with desuperheater water heater (WH) option (GSHPwDS). Predicted total annual energy savings, while providing space conditioning and water heating for a 2600 ft{sup 2} (242 m{sup 2}) house at 5 U.S. locations, ranged from 52 to 59%, averaging 55%, relative to the minimum efficiency suite. Predicted energy use for water heating was reduced 68 to 78% relative to resistance WH. Predicted total annual savings for the GSHPwDS relative to the same baseline averaged 22.6% with water heating energy use reduced by 10 to 30% from desuperheater contributions. The 1st generation (or alpha) prototype design for the GS-IHP was finalized in 2010 and field test samples were fabricated for testing by CM and by ORNL. Two of the alpha units were installed in 3700 ft{sup 2} (345 m{sup 2}) houses at the ZEBRAlliance site in Oak Ridge and field tested during 2011. Based on the steady-state performance demonstrated by the GS-IHPs it was projected that it would achieve >52% energy savings relative to the minimum efficiency suite at this specific site. A number of operational issues with the alpha units were identified indicating design changes needed to the system before market introduction could be accomplished. These were communicated to CM throughout the field test period. Based on the alpha unit test results and the diagnostic information coming from the field test

  15. Performance improvement of air source heat pump by using gas-injected rotary compressor

    Science.gov (United States)

    Wang, B. L.; Liu, X. R.; Ding, Y. C.; Shi, W. X.

    2017-08-01

    Rotary compressor is most widely used in small capacity refrigeration and heat pump systems. For the air source heat pump, the heating capacity and the COP will be obviously degraded when it is utilized in low temperature ambient. Gas injection is an effective method to enhance its performance under those situations, which has been well applied in air source heat pump with scroll compressor. However, the development of the gas injection technology in rotary compressor is relatively slow due to limited performance improvement. In this research, the essential reason constraining the improvement of the gas injection on the rotary compressor and its heat pump system is identified. Two new injection structures for rotary compressors has been put forward to overcome the drawback of traditional injection structures. Based on a verified numerical model, the thermodynamic performance of air source heat pumps with the new gas-injected rotary compressor are investigated. The results indicate that, compared to the air source heat pump with the traditional gas injected rotary compressor, the new injection structures both can enhance heating capacity and COP of the air source heat pump obviously.

  16. Heat pump contracting: a source of heat that takes care of the climate; Klimaschonende Waermeversorgung

    Energy Technology Data Exchange (ETDEWEB)

    Beyeler, F.

    2003-07-01

    This article discusses heat pump 'contracting solutions' used in the refurbishment of the central heating systems of two housing developments in Zurich and Thun, Switzerland. In these and other projects, the high level of investment needed for the installation of the heat pumps was met by third-party contractors, who install and operate the space heating and domestic hot water systems and sell the heat energy to the tenants. The system serving the 96 'Rietlihof' apartments in Zurich is operated by the public utilities of the City of Zurich, EWZ, the housing development in Thun by the Bernese power utility BKW. The article stresses the importance of professional planning and the correct choice of heat sources. The ecological and economical advantages of heating system refurbishment projects that use heat pumps built, financed and operated by contractors are discussed.

  17. Covering of heating load of object by using ground heat as a renewable energy source

    Directory of Open Access Journals (Sweden)

    Čenejac Aleksandra R.

    2012-01-01

    Full Text Available Rational use of energy, improving energy performance of buildings and use of renewable energy sources are the most important measures for reducing consumption of non-renewable primary energy (solid, liquid, and gaseous fuels, environmental protection and for the future sustainable development of mankind. In the total primary energy consumption great part is related to building industry, for heating spaces in which people stay and live. Renewable energy sources (RES present natural resources and they are one of the alternatives that allow obtaining heat for heating buildings, and by that they provide a significant contribution to the energy balance of a country. This paper analyzes the participation of ground source as RES, when the vertical (the probe in the ground and horizontal (registry in the ground heat exchangers are used for covering heating load of the building.

  18. Helium release from radioisotope heat sources

    Energy Technology Data Exchange (ETDEWEB)

    Peterson, D.E.; Early, J.W.; Starzynski, J.S.; Land, C.C.

    1984-05-01

    Diffusion of helium in /sup 238/PuO/sub 2/ fuel was characterized as a function of the heating rate and the fuel microstructure. The samples were thermally ramped in an induction furnace and the helium release rates measured with an automated mass spectrometer. The diffusion constants and activation energies were obtained from the data using a simple diffusion model. The release rates of helium were correlated with the fuel microstructure by metallographic examination of fuel samples. The release mechanism consists of four regimes, which are dependent upon the temperature. Initially, the release is controlled by movement of point defects combined with trapping along grain boundaries. This regime is followed by a process dominated by formation and growth of helium bubbles along grain boundaries. The third regime involves volume diffusion controlled by movement of oxygen vacancies. Finally, the release at the highest temperatures follows the diffusion rate of intragranular bubbles. The tendency for helium to be trapped within the grain boundaries diminishes with small grain sizes, slow thermal pulses, and older fuel.

  19. Ground Source Geothermal District Heating and Cooling System

    Energy Technology Data Exchange (ETDEWEB)

    Lowe, James William [Ball State Univ., Muncie, IN (United States)

    2016-10-21

    Ball State University converted its campus from a coal-fired steam boiler district heating system to a ground source heat pump geothermal district system that produces simultaneously hot water for heating and chilled water for cooling. This system will include the installation of 3,600 four hundred feet deep vertical closed loop boreholes making it the largest ground source geothermal district system in the country. The boreholes will act as heat exchangers and transfer heat by virtue of the earth’s ability to maintain an average temperature of 55 degree Fahrenheit. With growing international concern for global warming and the need to reduce worldwide carbon dioxide loading of the atmosphere geothermal is poised to provide the means to help reduce carbon dioxide emissions. The shift from burning coal to utilizing ground source geothermal will increase electrical consumption but an overall decrease in energy use and reduction in carbon dioxide output will be achieved. This achievement is a result of coupling the ground source geothermal boreholes with large heat pump chiller technology. The system provides the thermodynamic means to move large amounts of energy with limited energy input. Ball State University: http://cms.bsu.edu/About/Geothermal.aspx

  20. Infant respiratory symptoms associated with indoor heating sources.

    Science.gov (United States)

    Triche, Elizabeth W; Belanger, Kathleen; Beckett, William; Bracken, Michael B; Holford, Theodore R; Gent, Janneane; Jankun, Thomas; McSharry, Jean-Ellen; Leaderer, Brian P

    2002-10-15

    This study examined the effects of indoor heating sources on infant respiratory symptoms during the heating season of the first year of life. Mothers delivering babies between 1993 and 1996 at 12 hospitals in Connecticut and Virginia were enrolled. Daily symptom and heating source use information about their infant was obtained every 2 weeks during the first year of life. Heating sources included fireplace, wood stove, kerosene heater, and gas space heater use. Four health outcomes were analyzed by reporting period: days of wheeze, episodes of wheeze, days of cough, and episodes of cough. A large percentage of infants had at least one episode of cough (88%) and wheeze (33%) during the heating season of the first year of life. Wood stove, fireplace, kerosene heater, and gas space heater use was intermittent across the study period. In adjusted Poisson regression models controlling for important confounders, gas space heater use was associated with episodes and days of wheeze. Wood stove use was associated with total days of cough, and kerosene heater use was associated with episodes of cough. Fireplace use was not associated with any of the respiratory symptoms. Use of some heating sources appears related to respiratory symptoms in infants.

  1. Environmental assessment for radioisotope heat source fuel processing and fabrication

    Energy Technology Data Exchange (ETDEWEB)

    1991-07-01

    DOE has prepared an Environmental Assessment (EA) for radioisotope heat source fuel processing and fabrication involving existing facilities at the Savannah River Site (SRS) near Aiken, South Carolina and the Los Alamos National Laboratory (LANL) near Los Alamos, New Mexico. The proposed action is needed to provide Radioisotope Thermoelectric Generators (RTG) to support the National Aeronautics and Space Administration's (NASA) CRAF and Cassini Missions. Based on the analysis in the EA, DOE has determined that the proposed action does not constitute a major Federal action significantly affecting the quality of the human environment within the meaning of the National Environmental Policy Act (NEPA) of 1969. Therefore, an Environmental Impact Statement is not required. 30 refs., 5 figs.

  2. Simulation of embedded heat exchangers of solar aided ground source heat pump system

    Institute of Scientific and Technical Information of China (English)

    王芳; 郑茂余; 邵俊鹏; 李忠建

    2008-01-01

    Aimed at unbalance of soil temperature field of ground source heat pump system, solar aided energy storage system was established. In solar assisted ground-source heat pump (SAGSHP) system with soil storage, solar energy collected in three seasons was stored in the soil by vertical U type soil exchangers. The heat abstracted by the ground-source heat pump and collected by the solar collector was employed to heating. Some of the soil heat exchangers were used to store solar energy in the soil so as to be used in next winter after this heating period; and the others were used to extract cooling energy directly in the soil by circulation pump for air conditioning in summer. After that solar energy began to be stored in the soil and ended before heating period. Three dimensional dynamic numerical simulations were built for soil and soil heat exchanger through finite element method. Simulation was done in different strata month by month. Variation and restoration of soil temperature were studied. Economy and reliability of long term SAGSHP system were revealed. It can be seen that soil temperature is about 3 ℃ higher than the original one after one year’s running. It is beneficial for the system to operate for long period.

  3. Feasibility of drying system using waste heat as the heating source

    Science.gov (United States)

    Xie, M. N.; Shi, Y. L.; Chen, L. X.

    2016-08-01

    In this study, a wastewater heat pump system was proposed and its thermal performance was analyzed. The proposed system includes two evaporators: an air-source evaporator and a water-source evaporator. The air-source evaporator absorbs heat from the moist hot air which exhaust from the drying oven. The water-source evaporator absorbs heat from the waste water, while the waste water recovers heat from the mechanical energy, which was produced by cutting and polishing in stone production. The thermodynamic model was developed to evaluate the performance of the proposed system. The energetic analysis was carried out to investigate the influences of the temperature of fresh air. The results show significantly higher energy efficiency, compact-sized and energy-saving compared with the system which uses air as the heat source. Among the seven of alternative refrigerants (R152a, R123, R1234yf, R1234ze, R600a, R22 and R600) investigated, R123 was suggested to be used in this heat pump for its high heating efficiency, inflammable, very low ODP(Ozone Depletion Potential) and GWP(Global warming potential).

  4. Design, real-time modelling, simulation and digital implementation of phase-locked loop-based auto-synchronising current-sourced converter for an induction heating prototype

    Indian Academy of Sciences (India)

    MOLAY ROY; MAINAK SENGUPTA

    2017-06-01

    Induction heating (IH) converters operate just above resonant frequency, at near unity power factor (UPF), to supply power to the targeted work-piece. Some power electronic converter-fed IH systems use power control strategies based on dynamic tracking of the changing resonant frequency as the work-piece gets heated up (since inductance changes). Therefore, the correct in-process determination of the resonant frequency is essential. A method of dynamically detecting the resonant frequency is by calculating the phase-shift betweencurrent and voltage continuously during the process. In case of CSI- (and VSI-) fed IH, the phase-shift between voltage and current is zero at resonant frequency. Hence one way of identifying the resonant frequency is by varying the frequency until the phase-shift is zero. For controlling this phase-shift between current and voltage waveforms, most of the controllers use a phase-locked loop (PLL) IC. In this paper, a novel method for the dynamic tracking of resonant frequency is proposed and the practical implementation of the same, using a fieldprogrammable gate array (FPGA) based digital-PLL, is presented. The scheme is first simulated with generated off-line signal samples and then implemented on a real-time model of a CSI-fed IH application. Finally, thedigital-PLL logic is implemented on controller hardware and practically tested in a laboratory-made experimental set-up of 2 kW at a nominal frequency of 10 kHz. The switching frequency is auto-synchronising. This fact is practically verified both by varying (i) the geometric dimensions as also (ii) the initial temperature of the work-piece. It is practically observed in the oscillograms that the phase gets locked in few cycles (and hence ensures quick tracking of the dynamically changing resonant frequency for this set-up).

  5. Assessment of dynamic energy conversion systems for radioisotope heat sources

    Energy Technology Data Exchange (ETDEWEB)

    Thayer, G.R.; Mangeng, C.A.

    1985-06-01

    The use of dynamic conversion systems to convert the heat generated in a 7500 W(t) 90 Sr radioisotopic heat source to electricity is examined. The systems studies were Stirling; Brayton Cycle; three organic Rankines (ORCs) (Barber-Nichols/ORMAT, Sundstrand, and TRW); and an organic Rankine plus thermoelectrics. The systems were ranked for a North Warning System mission using a Los Alamos Multiattribute Decision Theory code. Three different heat source designs were used: case I with a beginning of life (BOL) source temperature of 640 C, case II with a BOL source temperature of 745/sup 0/C, and case III with a BOL source temperature of 945/sup 0/C. The Stirling engine system was the top-ranked system of cases I and II, closely followed by the ORC systems in case I and ORC plus thermoelectrics in case II. The Brayton cycle system was top-ranked for case III, with the Stirling engine system a close second. The use of /sup 238/Pu in heat source sizes of 7500 W(t) was examined and found to be questionable because of cost and material availability and because of additional requirements for analysis of safeguards and critical mass.

  6. MELCOR Sensitivity Analysis Focusing on the Heat Source

    Energy Technology Data Exchange (ETDEWEB)

    Maeng, Yunhwan; Sung, Joonyoung; Lee, Jaeyoung [Handong Global Univ., Pohang (Korea, Republic of)

    2015-10-15

    Present study conducted MELCOR code calculation by assuming the situation of complete loss of coolant accident (LOCA) scenario in a PWR 17 x 17 single spent fuel assembly, not an overall spent fuel pool. Present study conducted MELCOR analysis focusing on the heat source (decay heat, oxidation heat) and analysis object was PWR 17x17 spent nuclear fuel assembly. By changing the decay heat and oxidation coefficient, variation of peak cladding temperature to the time of the fuel assembly was analyzed. Different oxidation coefficient results the difference on the initiating time and existence of zirconium fire. From the result of MELCOR analysis, we found the criteria of decay heat that MELCOR simulation result showed the disagreement of peak cladding temperature, about 5.0 kW - 10.0 kW range.

  7. Melting of a phase change material in a horizontal annulus with discrete heat sources

    Directory of Open Access Journals (Sweden)

    Mirzaei Hooshyar

    2015-01-01

    Full Text Available Phase change materials have found many industrial applications such as cooling of electronic devices and thermal energy storage. This paper investigates numerically the melting process of a phase change material in a two-dimensional horizontal annulus with different arrangements of two discrete heat sources. The sources are positioned on the inner cylinder of the annulus and assumed as constant-temperature boundary conditions. The remaining portion of the inner cylinder wall as well as the outer cylinder wall is considered to be insulated. The emphasis is mainly on the effects of the arrangement of the heat source pair on the fluid flow and heat transfer features. The governing equations are solved on a non-uniform O type mesh using a pressure-based finite volume method with an enthalpy porosity technique to trace the solid and liquid interface. The results are obtained at Ra=104 and presented in terms of streamlines, isotherms, melting phase front, liquid fraction and dimensionless heat flux. It is observed that, depending on the arrangement of heat sources, the liquid fraction increases both linearly and non-linearly with time but will slow down at the end of the melting process. It can also be concluded that proper arrangement of discrete heat sources has the great potential in improving the energy storage system. For instance, the arrangement C3 where the heat sources are located on the bottom part of the inner cylinder wall can expedite the melting process as compared to the other arrangements.

  8. Stability of thermal structures with an internal heating source

    CERN Document Server

    Sanchez, Nestor

    2008-01-01

    We study the thermal equilibrium and stability of isobaric, spherical structures having a radiation source located at its center. The thermal conduction coefficient, external heating and cooling rates are represented as power laws of the temperature. The internal heating decreases with distance from the source r approximately as exp(-tau)/(r**2), being tau the optical depth. We find that the influence of the radiation source is important only in the central region, but its effect is enough to make the system thermally unstable above a certain threshold central temperature. This threshold temperature decreases as the internal heating efficiency increases, but, otherwise, it does not depend on the structure size. Our results suggest that a solar-like star migrating into a diffuse interstellar region may destabilize the surrounding medium.

  9. TEM Pump With External Heat Source And Sink

    Science.gov (United States)

    Nesmith, Bill J.

    1991-01-01

    Proposed thermoelectric/electromagnetic (TEM) pump driven by external source of heat and by two or more heat pipe radiator heat sink(s). Thermoelectrics generate electrical current to circulate liquid metal in secondary loop of two-fluid-loop system. Intended for use with space and terrestrial dual loop liquid metal nuclear reactors. Applications include spacecraft on long missions or terrestrial beacons or scientific instruments having to operate in remote areas for long times. Design modified to include multiple radiators, converters, and ducts, as dictated by particular application.

  10. NUMERICAL STUDY OF TRANSIENT THREE-DIMENSIONAL HEAT CONDUCTION PROBLEM WITH A MOVING HEAT SOURCE

    Directory of Open Access Journals (Sweden)

    Marko V Miloš

    2011-01-01

    Full Text Available A numerical study of transient three-dimensional heat conduction problem with a moving source is presented. For numerical solution Douglas-Gunn alternating direction implicit method is applied and for the moving heat source flux distribution Gaussian function is used. An influence on numerical solution of input parameters figuring in flux boundary conditions is examined. This include parameters appearing in Gaussian function and heat transfer coefficient from free convection boundaries. Sensitivity of cooling time from 800 to 500 °C with respect to input parameters is also tested.

  11. Laser induced heat source distribution in bio-tissues

    Science.gov (United States)

    Li, Xiaoxia; Fan, Shifu; Zhao, Youquan

    2006-09-01

    During numerical simulation of laser and tissue thermal interaction, the light fluence rate distribution should be formularized and constituted to the source term in the heat transfer equation. Usually the solution of light irradiative transport equation is given in extreme conditions such as full absorption (Lambert-Beer Law), full scattering (Lubelka-Munk theory), most scattering (Diffusion Approximation) et al. But in specific conditions, these solutions will induce different errors. The usually used Monte Carlo simulation (MCS) is more universal and exact but has difficulty to deal with dynamic parameter and fast simulation. Its area partition pattern has limits when applying FEM (finite element method) to solve the bio-heat transfer partial differential coefficient equation. Laser heat source plots of above methods showed much difference with MCS. In order to solve this problem, through analyzing different optical actions such as reflection, scattering and absorption on the laser induced heat generation in bio-tissue, a new attempt was made out which combined the modified beam broaden model and the diffusion approximation model. First the scattering coefficient was replaced by reduced scattering coefficient in the beam broaden model, which is more reasonable when scattering was treated as anisotropic scattering. Secondly the attenuation coefficient was replaced by effective attenuation coefficient in scattering dominating turbid bio-tissue. The computation results of the modified method were compared with Monte Carlo simulation and showed the model provided reasonable predictions of heat source term distribution than past methods. Such a research is useful for explaining the physical characteristics of heat source in the heat transfer equation, establishing effective photo-thermal model, and providing theory contrast for related laser medicine experiments.

  12. The Polyvalent Heat Supply System for Experimental Building of the Passive Type (area of 300 m2 Based on Renewable and Alternative Energy Sources

    Directory of Open Access Journals (Sweden)

    Basok, B.I.

    2014-11-01

    Full Text Available Results of the development and implementation of heat supply system for experimental building of the passive type are presented, optimal operating conditions are investigated, guidelines for the creation of heat supply systems for passive type buildings are provided.

  13. Heat source models in simulation of heat flow in friction stir welding

    DEFF Research Database (Denmark)

    Schmidt, Henrik Nikolaj Blich; Hattel, Jesper

    2004-01-01

    . The convective heat transfer due to the material flow affects the temperature fields. Models presented previously in the literature allow the heat to flow through the probe volume, and the majority neglects the influence of the contact condition as the sliding condition is assumed. In this work, a number......The objective of the present paper is to investigate the effect of including the tool probe and the material flow in the numerical modelling of heat flow in friction stir welding (FSW). The contact condition at the interface between the tool and workpiece controls the heat transfer mechanisms...... of cases is established. Each case represents a combination of a contact condition, i.e. sliding and sticking, and a stage of refinement regarding the heat source distribution. In the most detailed models, the heat flow is forced around the probe volume by prescribing a velocity field in shear layers...

  14. Heat Source Models in Simulation of Heat Flow in Friction Stir Welding

    DEFF Research Database (Denmark)

    Schmidt, Henrik Nikolaj Blich; Hattel, Jesper

    2004-01-01

    . The convective heat transfer due to the material flow affects the temperature fields. Models presented previously in literature allow the heat to flow through the probe volume, and the majority of them neglect the influence of the contact condition as the sliding condition is assumed. In the present work......The objective of the present paper is to investigate the effect of including the tool probe and the material flow in the numerical modelling of heat flow in Friction Stir Welding (FSW). The contact condition at the interface between the tool and workpiece controls the heat transfer mechanisms......, a number of cases are established. Each case represents a combination of a contact condition, i.e. sliding and sticking, and a stage of refinement regarding the heat source distribution. In the most detailed models the heat flow is forced around the probe volume by prescribing a velocity field in shear...

  15. On an Analog Controlled Precision Heat Power Source

    Science.gov (United States)

    Seilmayer, M.; Katepally, V. K.

    2017-07-01

    The analog controlled precision heat power source is the main part of a sensor development to estimate real time properties of the primary coolant in a 300 kW process cooling system. The measurement of physical properties like thermal conductivity or thermal diffusion requires a precise and accurate heater. The constant heat flux is then applied to the liquid under test to acquire its different properties. Here, commonly established control methods of heating with constant current or constant voltage may fail because the heating resistor changes its resistance with temperature. The idea is to utilize a power monitor circuit like the LT2940, which contains an analog multiplier with a control loop around it. The initial design and its assumed uncertainties will be discussed. The first version of the power controller shows an outstanding performance in terms of precision in a steady state. Compared to conventional switching mode power sources the approach with an analog controlled heater avoids EMI issues as well. The main goal of the present design is a precise source of heat power with less than 0.5% of error.

  16. Multicharged iron ions produced by using induction heating vapor source.

    Science.gov (United States)

    Kato, Yushi; Kubo, Takashi; Muramatsu, Masayuki; Tanaka, Kiyokatsu; Kitagawa, Atsushi; Yoshida, Yoshikazu; Asaji, Toyohisa; Sato, Fuminobu; Iida, Toshiyuki

    2008-02-01

    Multiply charged Fe ions are produced from solid pure material in an electron cyclotron resonance (ECR) ion source. We develop an evaporator by using induction heating with an induction coil which is made of bare molybdenum wire partially covered by ceramic beads in vacuum and surrounding and heating directly the pure Fe rod. Heated material has no contact with insulators, so that outgas is minimized. The evaporator is installed around the mirror end plate outside of the ECR plasma with its hole grazing the ECR zone. Helium or argon gas is usually chosen for supporting gas. The multicharged Fe ions up to Fe(13+) are extracted from the opposite side of mirror and against the evaporator, and then multicharged Fe ion beam is formed. We compare production of multicharged iron ions by using this new source with our previous methods.

  17. EnergyPlus Air Source Integrated Heat Pump Model

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Bo [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Energy and Transportation Science Division; Adams, Mark B. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Energy and Transportation Science Division; New, Joshua Ryan [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Energy and Transportation Science Division

    2016-03-30

    This report summarizes the development of the EnergyPlus air-source integrated heat pump model. It introduces its physics, sub-models, working modes, and control logic. In addition, inputs and outputs of the new model are described, and input data file (IDF) examples are given.

  18. Thermoelectricity without absorbing energy from the heat sources

    Science.gov (United States)

    Whitney, Robert S.; Sánchez, Rafael; Haupt, Federica; Splettstoesser, Janine

    2016-01-01

    We analyze the power output of a quantum dot machine coupled to two electronic reservoirs via thermoelectric contacts, and to two thermal reservoirs - one hot and one cold. This machine is a nanoscale analogue of a conventional thermocouple heat-engine, in which the active region being heated is unavoidably also exchanging heat with its cold environment. Heat exchange between the dot and the thermal reservoirs is treated as a capacitive coupling to electronic fluctuations in localized levels, modeled as two additional quantum dots. The resulting multiple-dot setup is described using a master equation approach. We observe an "exotic" power generation, which remains finite even when the heat absorbed from the thermal reservoirs is zero (in other words the heat coming from the hot reservoir all escapes into the cold environment). This effect can be understood in terms of a non-local effect in which the heat flow from heat source to the cold environment generates power via a mechanism which we refer to as Coulomb heat drag. It relies on the fact that there is no relaxation in the quantum dot system, so electrons within it have a non-thermal energy distribution. More poetically, one can say that we find a spatial separation of the first-law of thermodynamics (heat to work conversion) from the second-law of thermodynamics (generation of entropy). We present circumstances in which this non-thermal system can generate more power than any conventional macroscopic thermocouple (with local thermalization), even when the latter works with Carnot efficiency.

  19. Reprint of : Thermoelectricity without absorbing energy from the heat sources

    Science.gov (United States)

    Whitney, Robert S.; Sánchez, Rafael; Haupt, Federica; Splettstoesser, Janine

    2016-08-01

    We analyze the power output of a quantum dot machine coupled to two electronic reservoirs via thermoelectric contacts, and to two thermal reservoirs - one hot and one cold. This machine is a nanoscale analogue of a conventional thermocouple heat-engine, in which the active region being heated is unavoidably also exchanging heat with its cold environment. Heat exchange between the dot and the thermal reservoirs is treated as a capacitive coupling to electronic fluctuations in localized levels, modeled as two additional quantum dots. The resulting multiple-dot setup is described using a master equation approach. We observe an "exotic" power generation, which remains finite even when the heat absorbed from the thermal reservoirs is zero (in other words the heat coming from the hot reservoir all escapes into the cold environment). This effect can be understood in terms of a non-local effect in which the heat flow from heat source to the cold environment generates power via a mechanism which we refer to as Coulomb heat drag. It relies on the fact that there is no relaxation in the quantum dot system, so electrons within it have a non-thermal energy distribution. More poetically, one can say that we find a spatial separation of the first-law of thermodynamics (heat to work conversion) from the second-law of thermodynamics (generation of entropy). We present circumstances in which this non-thermal system can generate more power than any conventional macroscopic thermocouple (with local thermalization), even when the latter works with Carnot efficiency.

  20. Effect of the Presence of Semi-circular Cylinders on Heat Transfer From Heat Sources Placed in Two Dimensional Channel

    Directory of Open Access Journals (Sweden)

    Ahmed W. Mustava

    2013-04-01

    Full Text Available The effect of a semi-circular cylinders in a two dimensional channel on heat transfer by forced convection from two heat sources with a constant temperature has been studied numerically. Each channel contains two heat sources; one on the upper surface of the channel and the other on the lower surface of the channel. There is semi-circular cylinder under the source in upper surface and there is semi-circular cylinder above the source in lower surface. The location of the second heat source with its semi-cylinder has been changed and keeps the first source with its semi- cylinder at the same location. The flow and temperature field are studied numerically with different values of Reynolds numbers and for different spacing between the centers of the semi-cylinders. The laminar flow field is analyzed numerically by solving the steady forms of the two-dimensional incompressible Navier- Stokes and energy equations.  The Cartesian velocity components and pressure on a collocated (non-staggered grid are used as dependent variables in the momentum equations, which discretized by finite volume method, body fitted coordinates are used to represent the complex channel geometry accurately, and grid generation technique based on elliptic partial differential equations is employed. SIMPLE algorithm is used to adjust the velocity field to satisfy the conservation of mass.  The range of Reynolds number is (Re= 100 – 800 and the range of the spacing between the semi-cylinders is(1-4 and the Prandtl number is 0.7.The results showed that increasing the spacing between the semi-cylinders increases the average of Nusselt number of the first heat source for all Reynolds numbers. As well as the results show that the best case among the cases studied to enhance the heat transfer is when the second heat source and its semi-cylinder located on at the distance (S=1.5 from the first half of the cylinder and the Reynolds number is greater than (Re ≥ 400 because of the

  1. Ground Source Heat Pump Sub-Slab Heat Exchange Loop Performance in a Cold Climate

    Energy Technology Data Exchange (ETDEWEB)

    Mittereder, N.; Poerschke, A.

    2013-11-01

    This report presents a cold-climate project that examines an alternative approach to ground source heat pump (GSHP) ground loop design. The innovative ground loop design is an attempt to reduce the installed cost of the ground loop heat exchange portion of the system by containing the entire ground loop within the excavated location beneath the basement slab. Prior to the installation and operation of the sub-slab heat exchanger, energy modeling using TRNSYS software and concurrent design efforts were performed to determine the size and orientation of the system. One key parameter in the design is the installation of the GSHP in a low-load home, which considerably reduces the needed capacity of the ground loop heat exchanger. This report analyzes data from two cooling seasons and one heating season. Upon completion of the monitoring phase, measurements revealed that the initial TRNSYS simulated horizontal sub-slab ground loop heat exchanger fluid temperatures and heat transfer rates differed from the measured values. To determine the cause of this discrepancy, an updated model was developed utilizing a new TRNSYS subroutine for simulating sub-slab heat exchangers. Measurements of fluid temperature, soil temperature, and heat transfer were used to validate the updated model.

  2. Ground Source Heat Pump Sub-Slab Heat Exchange Loop Performance in a Cold Climate

    Energy Technology Data Exchange (ETDEWEB)

    Mittereder, Nick [IBACOS, Inc., Pittsburgh, PA (United States); Poerschke, Andrew [IBACOS, Inc., Pittsburgh, PA (United States)

    2013-11-01

    This report presents a cold-climate project that examines an alternative approach to ground source heat pump (GSHP) ground loop design. The innovative ground loop design is an attempt to reduce the installed cost of the ground loop heat exchange portion of the system by containing the entire ground loop within the excavated location beneath the basement slab. Prior to the installation and operation of the sub-slab heat exchanger, energy modeling using TRNSYS software and concurrent design efforts were performed to determine the size and orientation of the system. One key parameter in the design is the installation of the GSHP in a low-load home, which considerably reduces the needed capacity of the ground loop heat exchanger. This report analyzes data from two cooling seasons and one heating season.

  3. Innovative commercial ``ground source'' heat pump system sources and sinks: Engineering and economics

    Energy Technology Data Exchange (ETDEWEB)

    Sachs, H.M.; Lowenstein, A.I.; Henderson, H.I. Jr.; Carlson, S.W.; Risser, J.E.

    1998-07-01

    Geothermal heat pumps, which will be called GX systems in this paper, have been employed in specialty applications on both residential and commercial buildings for several decades. GX systems generally have very competitive life cycle costs, but somewhat higher initial costs. The incremental cost of the ground heat exchanger cost is close to the average cost per ton, so GX systems work best with very efficient building shells. Innovative methods can reduce the ground heat exchanger cost. These include better coupling of the heat exchange boreholes to the ground, hybrid systems that use low cost closed fluid coolers to supplement the ground heat exchanger where cooling loads dominate, open loop systems, and opportunistic systems that use sewage effluent or other non-standard sources for heat exchange. These approaches and their benefits are illustrated through five case studies.

  4. Medium-sized rock heat source systems. Mellanstora bergvaermesystem; Dimensioneringsanalyser

    Energy Technology Data Exchange (ETDEWEB)

    Spante, L.

    1989-05-24

    Results from these medium-sized rock heat source systems show that more functional trouble and inferior performance than expected are obtained if the borehole system is not adapted to the temperature demands of the heat pump cold transfer fluid. The design of the evaporator causes the evaporation temperature to become to low when the cold transfer fluid temperature reaches its lowest level for the year in two of the three plants studied. The third plant presents no functional trouble despite being operated at the same lowest cold transfer fluid temperature during the first years of operation. An analysis of complementary addition of boreholes in one of the plants with functional trouble reveals that the solution may be interesting if the heat pumps has to be capacity controlled for long periods during the heating season. In that plant the space for additional boreholes is limited, why the cost of this measure might be higher than the estimated SEK 240 per meter borehole. The computer code SBMA shows good agreement with measured weekly notations of the cold transfer fluid temperature during the first years of operation. The long-term temperature reduction caused by interaction between the closely located boreholes cannot be verified from only three years of operation. This fact gives cause for a follow-up of a number of medium-sized rock heat source systems for some additional years. 13 illus., 16 tabs. (author).

  5. Numerical analysis of heat exchange processes for the ground source heat pump system

    Science.gov (United States)

    Saito, H.; Muto, H.; Moritani, S.; Kohgo, Y.; Hamamoto, S.; Takemura, T.; Ohnishi, J.; Komatsu, T.

    2012-12-01

    Ground source heat pump systems (GSHP) use ground or groundwater as a heat source. They can achieve much higher coefficient of performance (COP) than conventional air source heat pump systems because the temperature of the ground is much more stable than that of the air. Heat energy in the ground is then viewed as one of the renewable energy sources. GSHP has been receiving great interests among countries in North America and Western Europe, as well as some developed countries in Asia because it can potentially reduce energy consumption and greenhouse gas emission. While GSHP can inject heat from the buildings to the ground for cooling during the summer, it can pump heat stored in the ground for heating during the winter. As some physical, chemical, and biological properties of the ground and groundwater are temperature dependent, running GSHP can eventually affect groundwater quality. The main objective of this project was to develop a model that allows predicting not only ground and groundwater temperatures but also changes in physical, chemical, and biological properties of ground and groundwater with GSHP under operations. This particular study aims at simulating heat exchange and transfer processes in the ground for a vertical-loop closed GSHP system. In the closed GSHP system, an anti-freezing solution is circulated inside the closed-loop tube, called U-tube, that is buried in the ground. Heat is then transferred to the anti-freezing solution in the U-tube by a heat exchanger. In this study we used HYDRUS to predict temperature of the anti-freezing solution, as well as that of the ground. HYDRUS allows one to simulate variably-saturated water flow and solute and heat transport in porous media numerically in two- and three-dimensional domains with great flexibility in defining boundary conditions. At first changes in anti-freezing solution temperatures measured were predicted in response to Thermal Response Test (TRT) conducted at our study site. Then, heat

  6. Heat pump using dual heat sources of air and water. Performance in cooling mode; Mizu kuki ryonetsugen heat pump no kenkyu. Reibo unten ni okeru seino

    Energy Technology Data Exchange (ETDEWEB)

    Ito, S.; Miura, N. [Kanagawa Institute of Technology, Kanagawa (Japan); Uchikawa, Y. [Kubota Corp., Osaka (Japan)

    1997-11-25

    When a heat pump is used for cooling purpose, it is possible to utilize different kinds of waste water as high-heat sources. However, these heat sources would have their temperatures vary with seasons and time in a day. Therefore, a discussion was given on performance of a heat pump when water and air heat sources are used for condensers during cooling operation independently, in series and in parallel, respectively. The air condenser shows an equivalent COP as compared with the water condenser when air temperature is lower by about 8 degC than water temperature. At the same heat source temperature, the COP for the water condenser indicated a value higher by about 0.6 than the case of the air condenser. A method to use condensers in parallel experiences little contribution from the air heat source, and performance of the heat pump decreases below the case of using the water heat source independently when the air heat source temperature becomes higher than that of the water heat source. In the case of series use in which a water condenser is installed in front and an air condenser in rear, its effect is exhibited when temperature in the air heat source is lower than that in the water heat source. Better performance was shown than in operating the water heat source independently. 2 refs., 9 figs.

  7. Measured Performance of a Low Temperature Air Source Heat Pump

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, R. K. [Johnson Research LLC, Pueblo West, CO (United States)

    2013-09-01

    A 4-ton Low Temperature Heat Pump (LTHP) manufactured by Hallowell International was installed in a residence near New Haven, Connecticut and monitored over two winters of operation. After attending to some significant service issues, the heat pump operated as designed. This report should be considered a review of the dual compressor 'boosted heat pump' technology. The Low Temperature Heat Pumpsystem operates with four increasing levels of capacity (heat output) as the outdoor temperature drops. The system was shown to select capacity correctly, supplying the appropriate amount of heat to the house across the full range of outdoor temperatures. The system's Coefficient of Performance (Seasonal COP, or SCOP) over two entire winters was calculated, based on measured data, to be 3.29over the first winter and 2.68 over the second winter. A second seasonal efficiency calculation by a different method yielded a SCOP of 2.78 for the first winter and 2.83 for the second winter. This second seasonal efficiency calculation was determined by comparing measured heat pump energy use to the in situ energy use with resistance heat alone. This method is the ratio of the slopes of thedaily energy use load lines.

  8. Promising design options for the encapsulated nuclear heat source reactor

    Energy Technology Data Exchange (ETDEWEB)

    Conway, L.; Carelli, M.D.; Dzodzo, M. [Westinghouse Science and Technology, Pittsburgh, PA (United States); Hossain, Q.; Brown, N.W. [Lawrence Livermore National Lab., CA (United States); Wade, D.C.; Sienick, J.J. [Argonne National Lab., IL (United States); Greenspan, E.; Kastenberg, W.E.; Saphier, D. [University of California Dept of Nuclear Engineering, Berkeley, CA (United States)

    2001-07-01

    Promising design options for the Encapsulated Nuclear Heat Source (ENHS) liquid-metal cooled fast reactor were identified during the first year of the DOE NERI program sponsored feasibility study. Many opportunities for incorporation of innovations in design and fabrication were identified. Three of the innovations are hereby described: a novel IHX (intermediate heat exchanger) made of a relatively small number of rectangular channels, an ENHS module design featuring 100% natural circulation, and a novel conceptual design of core support and fuelling. As a result of the first year study the ENHS concept appears more practical and more promising than perceived at the outset of this study. (authors)

  9. Design of serially connected ammonia-water hybrid absorption-compression heat pumps for district heating with the utilisation of a geothermal heat source

    DEFF Research Database (Denmark)

    Jensen, Jonas Kjær; Ommen, Torben Schmidt; Markussen, Wiebke Brix;

    2016-01-01

    District heating (DH) can reduce the primary energy consumption in urban areas with significant heat demands. The design of a serially connected ammonia-water hybrid absorption-compression heat pump system was investigated for operation in the Greater Copenhagen DH network in Denmark, in order...... to supply 7.2 MW heat at 85 °C utilizing a geothermal heat source at 73 °C. Both the heat source and heat sink experience a large temperature change over the heat transfer process, of which a significant part may be achieved by direct heat exchange. First a generic study with a simple representation...

  10. Modeling and analysis of a transcritical rankine power cycle with a low grade heat source

    DEFF Research Database (Denmark)

    Nguyen, Chan; Veje, Christian

    2011-01-01

    A transcritical carbon dioxide (CO2) Rankine power cycle has been analyzed based on first and second law of thermodynamics. Detailed simulations using distributed models for the heat exchangers have been performed in order to develop the performance characteristics in terms of e.g., thermal effic...... conditions for the high side pressure. In addition the results underline that the investment cost for additional heat exchange components such as an internal heat exchanger may be unprofitable in the case where the heat source is free.......A transcritical carbon dioxide (CO2) Rankine power cycle has been analyzed based on first and second law of thermodynamics. Detailed simulations using distributed models for the heat exchangers have been performed in order to develop the performance characteristics in terms of e.g., thermal...... efficiency, exergetic efficiency and specific net power output. A generic cycle configuration has been used for analysis of a geothermal energy heat source. This model has been validated against similar calculations using industrial waste heat as the energy source. Calculations are done with fixed...

  11. Performance analysis of air source heat pump system for office building

    Energy Technology Data Exchange (ETDEWEB)

    Han, Dong Won; KIm, Yong Chan [Korea University, Seoul (Korea, Republic of); Chang, Young Soo [School of Mechanical System Engineering, Kookmin University, Seoul (Korea, Republic of)

    2016-11-15

    In this study, the performance of an air source heat pump system installed in a commercial building is analyzed using the developed heat pump performance model and building load simulation data of several regions in Korea. The performance test of an air source heat pump system with a variable speed compressor is tested to develop model that considers changes in the performance characteristics of the heat pump system under various operating conditions. The heat pump system is installed in an environmental chamber, and the experimental equipment is set up according to the manufacturer' specifications as well as the AHRI 1230 test specifications. The performance test conditions of the heat pump system are selected using a central composite design method, in which 29 points for each cooling and heating mode are selected. The developed performance model based on experimental data predicts experimental values with an error of ±5 %. Building cooling and heating loads in three regions in Korea are analyzed using TRNSYS software, which includes standard building and weather data from Seoul, Daejeon and Busan in Korea. The effects of outdoor air temperature and part load ratio on the performance and regional monthly average power consumption of the heat pump system are analyzed.

  12. Testing of PCM Heat Storage Modules with Solar Collectors as Heat Source

    DEFF Research Database (Denmark)

    Englmair, Gerald; Dannemand, Mark; Johansen, Jakob Berg;

    2016-01-01

    . In long periods with high level of irradiance several modules were charged in parallel due to the limited heat exchange capacity of the integrated heat exchanger of the modules. After the modules were heated to more than 80° C they were set to passively cool down. Modules reached 30 °C in a period......A latent heat storage based on the phase change material Sodium Acetate Trihydrate (SAT) has been tested as part of a demonstration system. The full heat storage consisted of 4 individual modules each containing about 200 kg of sodium acetate trihydrate with different additives. The aim...... was to actively utilize the ability of the material to supercool to obtain long storage periods. The modules were charged with solar heat supplied by 22.4 m2 evacuated tubular collectors. The investigation showed that it was possible to fully charge one module within a period of 270 minutes with clear skies...

  13. The impact of municipal waste combustion in small heat sources

    Science.gov (United States)

    Vantúch, Martin; Kaduchová, Katarína; Lenhard, Richard

    2016-06-01

    At present there is a tendency to make greater use for heating houses for burning solid fuel, such as pieces of wood, coal, coke, local sources of heat to burn natural gas. This tendency is given both the high price of natural gas as well as the availability of cheaper solid fuel. In many cases, in the context saving heating costs, respectively in the context of the disposal of waste is co-incinerated with municipal solid fuels and wastes of different composition. This co entails increased production emissions such as CO (carbon monoxide), NOx (nitrogen oxides), particulate matter (particulate matter), PM10, HCl (hydrogen chloride), PCDD/F (polychlorinated dibenzodioxins and dibenzofurans), PCBs (polychlorinated biphenyls) and others. The experiment was focused on the emission factors from the combustion of fossil fuels in combination with municipal waste in conventional boilers designed to burn solid fuel.

  14. Development of an Air-Source Heat Pump Integrated with a Water Heating / Dehumidification Module

    Energy Technology Data Exchange (ETDEWEB)

    Rice, C Keith [ORNL; Uselton, Robert B. [Lennox Industries, Inc; Shen, Bo [ORNL; Baxter, Van D [ORNL; Shrestha, Som S [ORNL

    2014-01-01

    A residential-sized dual air-source integrated heat pump (AS-IHP) concept is under development in partnership between ORNL and a manufacturer. The concept design consists of a two-stage air-source heat pump (ASHP) coupled on the air distribution side with a separate novel water heating/dehumidification (WH/DH) module. The motivation for this unusual equipment combination is the forecast trend for home sensible loads to be reduced more than latent loads. Integration of water heating with a space dehumidification cycle addresses humidity control while performing double-duty. This approach can be applied to retrofit/upgrade applications as well as new construction. A WH/DH module capable of ~1.47 L/h water removal and ~2 kW water heating capacity was assembled by the manufacturer. A heat pump system model was used to guide the controls design; lab testing was conducted and used to calibrate the models. Performance maps were generated and used in a TRNSYS sub-hourly simulation to predict annual performance in a well-insulated house. Annual HVAC/WH energy savings of ~35% are predicted in cold and hot-humid U.S. climates compared to a minimum efficiency baseline.

  15. North Village Ground Source Heat Pump Demonstration Project

    Energy Technology Data Exchange (ETDEWEB)

    Redderson, Jeff

    2015-08-03

    This project demonstrated the feasibility of converting from a traditional direct exchange system to a ground source heat pump system on a large scale, multiple building apartment complex on a university campus. A total of ten apartment buildings were converted using vertical well fields and a ground source loop that connected the 24 apartments in each building into a common system. The system has yielded significant operational savings in both energy and maintenance and transformed the living environments of these residential buildings for our students.

  16. Indoor heating sources and respiratory symptoms in nonsmoking women.

    Science.gov (United States)

    Triche, Elizabeth W; Belanger, Kathleen; Bracken, Michael B; Beckett, William S; Holford, Theodore R; Gent, Janneane F; McSharry, Jean-Ellen; Leaderer, Brian P

    2005-05-01

    Secondary heating appliances are important indoor sources of air pollution, including particulate matter, nitrogen dioxide (NO2), and sulfur dioxide (SO2). We hypothesized that the use of secondary heating sources increases respiratory symptoms in women living in nonsmoking households and specifically that concentrations of SO2 and NO2 emitted from heating sources are associated with respiratory symptoms. Mothers who delivered babies at 12 hospitals in Connecticut and Virginia (1993-1996) were enrolled. There were 888 women who contributed symptom and exposure information during the winter heating season (15 October to 15 April), for a total of 9783 reporting periods (median = 12 reporting periods per woman, interquartile range 11-12). Adjusted rate ratios (RRs) of effects of source use and measured concentrations on rate of days with symptoms were obtained using generalized estimating equations for a log-linear Poisson model, controlling age, education, race, history of allergies, number of children, dwelling type, and residence state. In adjusted models, each hour-per-day increase in kerosene heater use is associated with an increase in wheezing (RR = 1.06; 95% confidence interval (CI) = 1.01-1.11). Each hour of fireplace use is associated with increased cough (1.05; 1.01-1.09), sore throat (1.04; 1.00-1.08), and marginally with chest tightness (1.05; 0.99-1.12). Each 10 ppb increase in SO2 (a proxy for sulfate aerosol) is associated with increased wheezing (1.57; 1.10-2.26) and chest tightness (1.32; 1.01-1.71). Emissions from fireplaces, gas space heaters, and kerosene heaters may contribute to respiratory symptoms in a population of nonsmoking women.

  17. Temperature distribution of an infinite slab under point heat source

    Directory of Open Access Journals (Sweden)

    Wu Zhao-Chun

    2014-01-01

    Full Text Available The temperature field in an infinite slab under an instantaneous or continuous point heat source is studied numerically. The numerical results reveal the temperature distribution and its change regularity, which are significant for the temperature control encountered in many practical manufacturing processes, such as the laser treatment processes on the surface of films, welding and cutting, and even the design of measuring devices for thermal properties of material.

  18. Recuperator with microjet technology as a proposal for heat recovery from low-temperature sources

    Science.gov (United States)

    Wajs, Jan; Mikielewicz, Dariusz; Fornalik-Wajs, Elżbieta; Bajor, Michał

    2015-12-01

    A tendency to increase the importance of so-called dispersed generation, based on the local energy sources and the working systems utilizing both the fossil fuels and the renewable energy resources is observed nowadays. Generation of electricity on industrial or domestic scale together with production of heat can be obtained for example through employment of the ORC systems. It is mentioned in the EU directive 2012/27/EU for cogenerative production of heat and electricity. For such systems the crucial points are connected with the heat exchangers, which should be small in size but be able to transfer high heat fluxes. In presented paper the prototype microjet heat exchanger dedicated for heat recovery systems is introduced. Its novel construction is described together with the systematical experimental analysis of heat transfer and flow characteristics. Reported results showed high values of the overall heat transfer coefficient and slight increase in the pressure drop. The results of microjet heat exchanger were compared with the results of commercially available compact plate heat exchanger.

  19. Recuperator with microjet technology as a proposal for heat recovery from low-temperature sources

    Directory of Open Access Journals (Sweden)

    Wajs Jan

    2015-12-01

    Full Text Available A tendency to increase the importance of so-called dispersed generation, based on the local energy sources and the working systems utilizing both the fossil fuels and the renewable energy resources is observed nowadays. Generation of electricity on industrial or domestic scale together with production of heat can be obtained for example through employment of the ORC systems. It is mentioned in the EU directive 2012/27/EU for cogenerative production of heat and electricity. For such systems the crucial points are connected with the heat exchangers, which should be small in size but be able to transfer high heat fluxes. In presented paper the prototype microjet heat exchanger dedicated for heat recovery systems is introduced. Its novel construction is described together with the systematical experimental analysis of heat transfer and flow characteristics. Reported results showed high values of the overall heat transfer coefficient and slight increase in the pressure drop. The results of microjet heat exchanger were compared with the results of commercially available compact plate heat exchanger.

  20. Towards a Future of District Heating Systems with Low-Temperature Operation together with Non-Fossil Fuel Heat Sources

    DEFF Research Database (Denmark)

    Tol, Hakan; Dinçer, Ibrahim; Svendsen, Svend

    2012-01-01

    This study focused on investigation of non-fossil fuel heat sources to be supplied to low-energy district heating systems operating in low temperature such as 55 C and 25 C in terms of, respectively, supply and return. Vast variety of heat sources classed in categories such as fossil fuel, renewa...

  1. Faceted Taxonomy-Based Sources

    Science.gov (United States)

    Tzitzikas, Yannis

    The objective of this chapter is to explain the underlying mathematical structure of faceted taxonomy-based sources and to provide some common notions and notations that are used in some parts of the book. Subsequently, and on the basis of the introduced formalism, this chapter describes the interaction between a user and an information source that supports dynamic taxonomies and faceted search.

  2. Impact factors on the long-term sustainability of Borehole Heat Exchanger coupled Ground Source Heat Pump System

    Science.gov (United States)

    Shao, Haibing; Hein, Philipp; Görke, Uwe-Jens; Bucher, Anke; Kolditz, Olaf

    2016-04-01

    In recent years, Ground Source Heat Pump System (GSHPS) has been recognized as an efficient technology to utilize shallow geothermal energy. Along with its wide application, some GSHPS are experiencing a gradual decrease in Borehole Heat Exchanger (BHE) outflow temperatures and thus have to be turned off after couple of years' operation. A comprehensive numerical investigation was then performed to model the flow and heat transport processes in and around the BHE, together with the dynamic change of heat pump efficiency. The model parameters were based on the soil temperature and surface weather condition in the Leipzig area. Different scenarios were modelled for a service life of 30 years, to reveal the evolution of BHE outflow and surrounding soil temperatures. It is found that lateral groundwater flow and using BHE for cooling will be beneficial to the energy recovery, along with the efficiency improvement of the heat pump. In comparison to other factors, the soil heat capacity and thermal conductivity are considered to have minor impact on the long-term sustainability of the system. Furthermore, the application of thermally enhanced grout material will improve the sustainability and efficiency. In contrast, it is very likely that undersized systems and improper grouting are the causes of strong system degradation.

  3. Wuhan Ground Source Heat Pump Engineering Economic Evaluation Based on the Life Cycle%基于全寿命周期的地源热泵工程经济性评价

    Institute of Scientific and Technical Information of China (English)

    付红阳; 陈伟; 张国辉

    2012-01-01

    通过分析我国地源热泵工程的发展现状及国家和武汉地区政策标准,实地调研武汉地区8个地源热泵工程项目相关经济数据,构建武汉地区地源热泵工程经济性评价体系,通过费用构成分析、能耗分析、运行费用分析和环境评价分析对地源热泵工程进行全寿命周期经济性评价,从而为武汉地区乃至全国推广地源热泵工程提供相关依据和建议。%By analyzing development situation of ground source heat pump engineering and policy standards of China and Wuhan province,the paper investigates related economic data of Wuhan eight ground source heat pump engineering,establishes the economic evaluation system of Wuhan ground source heat pump engineering,and do economic evaluates to ground source heat pump engineering of Wuhan from the analysis of expense components,the energy consumption,the operation cost and the environment evaluation,in order to provide relevant basis and suggestions to promote the promote ground source heat pump engineering of Wuhan to the whole nation.

  4. Ground-source heat pump case studies and utility programs

    Energy Technology Data Exchange (ETDEWEB)

    Lienau, P.J.; Boyd, T.L.; Rogers, R.L.

    1995-04-01

    Ground-source heat pump systems are one of the promising new energy technologies that has shown rapid increase in usage over the past ten years in the United States. These systems offer substantial benefits to consumers and utilities in energy (kWh) and demand (kW) savings. The purpose of this study was to determine what existing monitored data was available mainly from electric utilities on heat pump performance, energy savings and demand reduction for residential, school and commercial building applications. In order to verify the performance, information was collected for 253 case studies from mainly utilities throughout the United States. The case studies were compiled into a database. The database was organized into general information, system information, ground system information, system performance, and additional information. Information was developed on the status of demand-side management of ground-source heat pump programs for about 60 electric utility and rural electric cooperatives on marketing, incentive programs, barriers to market penetration, number units installed in service area, and benefits.

  5. A theoretical estimation of the pre-breakdown-heating time in the underwater discharge acoustic source

    Institute of Scientific and Technical Information of China (English)

    Wang Yi-Bo; Wang Shang-Wu; Zeng Xin-Wu

    2012-01-01

    One of the common characteristics of the electrothermal breakdown in an underwater discharge acoustic source(UDAS)is the existence of a pre-breakdown-heating phase.In our experiment,two phenomena were observed:(1)the breakdown time that takes on high randomicity and obeys a "double-peak" stochastic distribution;(2)the higher salt concentration that reduces the residual voltage and causes 100% non-breakdown.The mechanism of electrothermal breakdown is analysed.To specify the end of the pre-breakdown-heating phase,a "border boiling" assumption is proposed,in which the breakdown time is assumed to be the time needed to heat the border water around the initial arc to 773 K.Based on this ‘border boiling' assumption,the numerical simulation is performed to evaluate the effects of two heating mechanisms:the Joule heating from the ionic current,and the radiation heating from the initial arc.The simulation results verify the theoretical explanations to these two experiment phenomena:(1)the stochastic distribution of the radius of the initial arc results in the randomicity of the breakdown time;(2)the difference in efficiency between the radiation heating and the Joule heating determines that,in the case of higher salt concentration,more energy will be consumed in the pre-breakdown-heating phase.

  6. Work output and efficiency at maximum power of linear irreversible heat engines operating with a finite-sized heat source.

    Science.gov (United States)

    Izumida, Yuki; Okuda, Koji

    2014-05-01

    We formulate the work output and efficiency for linear irreversible heat engines working between a finite-sized hot heat source and an infinite-sized cold heat reservoir until the total system reaches the final thermal equilibrium state with a uniform temperature. We prove that when the heat engines operate at the maximum power under the tight-coupling condition without heat leakage the work output is just half of the exergy, which is known as the maximum available work extracted from a heat source. As a consequence, the corresponding efficiency is also half of its quasistatic counterpart.

  7. Low Temperature Heat Source Utilization Current and Advanced Technology

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, James H. Jr.; Dambly, Benjamin W.

    1992-06-01

    Once a geothermal heat source has been identified as having the potential for development, and its thermal, physical, and chemical characteristics have been determined, a method of utilization must be decided upon. This compendium will touch upon some of these concerns, and hopefully will provide the reader with a better understanding of technologies being developed that will be applicable to geothermal development in East Africa, as well as other parts of the world. The appendices contain detailed reports on Down-the-Well Turbo Pump, The Vapor-Turbine Cycle for Geothermal Power Generation, Heat Exchanger Design for Geothermal Power Plants, and a Feasibility Study of Combined Power and Water Desalting Plant Using Hot Geothermal Water. [DJE-2005

  8. HTGR nuclear heat source component design and experience

    Energy Technology Data Exchange (ETDEWEB)

    Peinado, C.O.; Wunderlich, R.G.; Simon, W.A.

    1982-05-01

    The high-temperature gas-cooled reactor (HTGR) nuclear heat source components have been under design and development since the mid-1950's. Two power plants have been designed, constructed, and operated: the Peach Bottom Atomic Power Station and the Fort St. Vrain Nuclear Generating Station. Recently, development has focused on the primary system components for a 2240-MW(t) steam cycle HTGR capable of generating about 900 MW(e) electric power or alternately producing high-grade steam and cogenerating electric power. These components include the steam generators, core auxiliary heat exchangers, primary and auxiliary circulators, reactor internals, and thermal barrier system. A discussion of the design and operating experience of these components is included.

  9. Urban heat islands in the subsurface as sustainable source for geothermal energy

    Science.gov (United States)

    Menberg, Kathrin; Bayer, Peter; Blum, Philipp

    2014-05-01

    The urban heat island (UHI) is not a phenomenon that solely occurs in the atmosphere with increased air temperatures. We also observe it in the subsurface, and groundwater temperatures in shallow aquifers are strongly influenced by anthropogenic land surface alterations. Widespread thermal anomalies, which are triggered by various processes, such as increased ground surface temperatures (GST) and heat loss from buildings, can be found under many urban areas. With groundwater temperatures elevated by several degrees these aquifers represent large amounts of stored thermal energy. However, to exploit these attractive geothermal reservoirs efficiently and sustainably, the processes, which lead to the profound subsurface urban warming, need to be identified and quantified. In the current study, the spatial extension of the heat anomalies beneath several German cities, such as Berlin, Munich, Karlsruhe and Cologne, is scrutinized by mapping groundwater temperatures in a dense network of observation wells. With the high-resolved spatial distribution of groundwater temperatures, the dominant heat sources and important driving factors can be identified and incorporated into an analytical heat flux model. The annual anthropogenic heat input into the aquifer originating from several heat sources, such as increased GST, basements, sewage networks, district heating networks and reinjections of thermal waste water, is estimated by a Monte Carlo simulation for the cities of Cologne and Karlsruhe. All studied cities exhibit aquifers with significantly elevated temperatures, with the highest temperatures of up to 18°C prevailing in the densely built-up city centers. But also in suburban and industrial areas groundwater temperatures are several degrees above the rural background. The accumulated heat content in the urban aquifers can be estimated based on the thermal ground properties. This content is compared to the annual space heating demand in order to analyze the space

  10. Regularities pertinent to heat transfer between torch gas layers and steam boiler firebox waterwalls. Part I. Geometrical and physical torch model as a source of heat radiation

    Science.gov (United States)

    Makarov, A. N.

    2014-09-01

    The progress seen in the 19th-21st centuries in the development of methods for calculating heat transfer in torch furnaces, fireboxes, and combustion chambers is analyzed. Throughout the 20th century, calculations of heat transfer were carried out based on the law for radiation from solid bodies deduced by Y. Stefan and L. Boltzmann. It is shown that the use of this law for calculating heat transfer of a torch (a gaseous source of radiation) in heating furnaces and power-generating installations leads to incorrect results. It is substantiated that there is crisis of methods for calculating heat transfer in torch furnaces and power-generating installations. Geometrical and physical torch models in the form of radiating cylindrical gas volumes as sources of heat radiation are proposed for overcoming this crisis.

  11. Experimental Study of Melting Heat Transfer in an Enclosure with Three Discrete Protruding Heat Sources

    Institute of Scientific and Technical Information of China (English)

    YonglinJu; ZhongqiChen; 等

    1998-01-01

    To explore the possibility of using solid-liquid phase change cooling to those periodically or intermittently operated electronic equipment,a detail of experimental study of time-dependent melting heat transfer in a rectangular enclosure with three discrete proturding heat sources is presented.A series of experimental measurement in an enclosure with phase change materials (PCM)of n-octadecane of experimental measurement in an enclosure with phase change materials(PCM) of -octadecane heated by three discrete protruding heat sources at a constant rate on one of its vertical wall has been described.The opposite wall of the enclosure is cooled at a constant temperature and all other walls of the enclosure are insulated.The time-dependent solid-liquid shapes of the interface during melting process,the variation of surface temperature and the effects of sulbcooling are investigated.An empirical correlation predicting the relationship between the liquid phase fraction and subcooling is given.

  12. Field experiment on coalmine heat disaster governance using cold source from surface water

    Institute of Scientific and Technical Information of China (English)

    Guo Pingye; Zhu Guolong; Liu Yuqing; Duan Mengmeng; Wu Junyin

    2014-01-01

    Regarding the lack of cold source for underground cooling systems from either mine inflow or return air, field experiments were taken in a high temperature deep coal mine with abundant cold source from surface water. Taking Sanhejian coal mine as an example, this paper introduced the technology scheme of heat disaster governance using surface water cold source. The paper presents the basics of this field experiment at the beginning, following by the design and site layout of the cooling system including the analysis and calculation of cold source. Numerical calculation method is also applied based on the operation parameters to simulate the influence to the surface river ecosystem. The results suggest that the temperature of surface water shall be lower than 34 ?C after heat exchange, and when more cooling capacities are needed in the future, increasing the water flow is more favorable than increasing the cooling range of water, which is better for the ecological environment protection.

  13. Heat buffers improve capacity and exploitation degree of geothermal energy sources

    NARCIS (Netherlands)

    Ooster, van 't A.; Wit, de J.; Janssen, E.G.O.N.; Ruigrok, J.

    2008-01-01

    This research focuses on the role of heat buffers to support optimal use of combinations of traditional and renewable heat sources like geothermal heat for greenhouse heating. The objective was to determine the contribution of heat buffers to effective new combinations of resources that satisfy gree

  14. Effects of aqueous humor hydrodynamics on human eye heat transfer under external heat sources.

    Science.gov (United States)

    Tiang, Kor L; Ooi, Ean H

    2016-08-01

    The majority of the eye models developed in the late 90s and early 00s considers only heat conduction inside the eye. This assumption is not entirely correct, since the anterior and posterior chambers are filled aqueous humor (AH) that is constantly in motion due to thermally-induced buoyancy. In this paper, a three-dimensional model of the human eye is developed to investigate the effects AH hydrodynamics have on the human eye temperature under exposure to external heat sources. If the effects of AH flow are negligible, then future models can be developed without taking them into account, thus simplifying the modeling process. Two types of external thermal loads are considered; volumetric and surface irradiation. Results showed that heat convection due to AH flow contributes to nearly 95% of the total heat flow inside the anterior chamber. Moreover, the circulation inside the anterior chamber can cause an upward shift of the location of hotspot. This can have significant consequences to our understanding of heat-induced cataractogenesis. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.

  15. Convective heat transfer enhancement of laminar flow of latent functionally thermal fluid in a circular tube with constant heat flux: internal heat source model and its application

    Institute of Scientific and Technical Information of China (English)

    张寅平; 胡先旭; 郝磬; 王馨

    2003-01-01

    This paper analyzes the convective heat transfer enhancement mechanism of latent heat functionally thermal fluid. By using the proposed internal heat source model, the influence of each factor affecting the heat transfer enhancement of laminar flow in a circular tube with constant heat flux is analyzed. The main influencing factors and the mechanisms of heat transfer enhancement are clarified, and the influences of the main factors on the heat transfer enhancement are quantitatively analyzed. A modified Nusselt number for internal flow is introduced to describe more effectively the degree of heat transfer enhancement for latent functionally thermal fluid.

  16. Analysis of Magnetic Field Effects on Distributed Heat Sources in a Nanofluid-Filled Enclosure by Natural Convection

    Directory of Open Access Journals (Sweden)

    Alireza Aghaei

    2016-01-01

    Full Text Available This paper studies the effect of magnetic field on the flow field and heat transfer of nanofluid with variable properties in the square enclosure with two arrangements of heat sources. Based upon numerical predictions, the effects of pertinent parameters such as the Rayleigh number (103, 104 and 105, the Hartmann number (0, 25, 50, 75 and 100 and the solid volume fraction (0 to 4% on the flow and temperature fields and the heat transfer performance of the enclosure are examined. For the numerical solution of conservation equations, finite volume method and SIMPLER algorithm was used. The results show that the heat transfer rate influenced by district heat sources and it increases with distributing heat sources on the side walls and it increases with an increase of the Rayleigh number and volume fraction, but decreases with an increase of Hartmann number.

  17. Heat pump using dual heat sources of air and water. Performance with heat sources arranged in parallel; Mizu kuki ryonetsugen heat pump no kenkyu. Netsugen heiretsu unten ni okeru seino

    Energy Technology Data Exchange (ETDEWEB)

    Ito, S.; Miura, N.; Sato, S. [Kanagawa Institute of Technology, Kanagawa (Japan); Uchikawa, Y.; Hamada, K. [Kubota Corp., Osaka (Japan)

    1996-10-27

    A heat pump system using water and air as heat sources was built and evaluated for its performance. In this system, evaporators may be operated singly or as connected in parallel or series, and, for each case, the quantity of heat acquired may be measured and system performance may be quantitatively evaluated. The findings follow. When the two heat sources are equal in temperature in the single-evaporator operation, the evaporation temperature is about 7{degree}C higher on the water side than on the air side, and the performance coefficient is about 0.7 higher. When the air heat source temperature is 25{degree}C in the parallel operation, like quantities of heat are obtained from both heat sources, and collection of heat from the water increases with a decrease in the air heat source temperature but, with an increase, collection from the air increases. When the air heat source temperature decreases, the evaporation temperature decreases in the single-evaporator working on the air and in the parallel operation but it levels off in the single-evaporator working on the water alone. When the water heat source temperature decreases, evaporation temperature drop is sharper in the single-evaporator working on the water than in the parallel operation, which suggests the transfer from the parallel operation to the single-evaporator working on the air. In the single-evaporator operation on the water heat source, the evaporation temperature linearly decreases with an increase in superheating. 1 ref., 10 figs.

  18. NETWORK MODEL AND ALGORITHM FOR SOLVING PROBLEM OF OPTIMUM THERMAL LOAD DISTRIBUTION AMONG HEAT-SOURCES OF ENTERPRISE HEATING SYSTEM

    Directory of Open Access Journals (Sweden)

    V. A. Sednin

    2010-01-01

    Full Text Available The paper  presents an algorithm for optimization of thermal load distribution among heat-sources in the system of centralized heat supply. The algorithm can be used while elaborating plans for development of heat supply systems in cities and settlements.

  19. Hydrogen and renewable energy sources integrated system for greenhouse heating

    Directory of Open Access Journals (Sweden)

    Ileana Blanco

    2013-09-01

    Full Text Available A research is under development at the Department of Agro- Environmental Sciences of the University of Bari “Aldo Moro” in order to investigate the suitable solutions of a power system based on solar energy (photovoltaic and hydrogen, integrated with a geothermal heat pump for powering a self sustained heated greenhouse. The electrical energy for heat pump operation is provided by a purpose-built array of solar photovoltaic modules, which supplies also a water electrolyser system controlled by embedded pc; the generated dry hydrogen gas is conserved in suitable pressured storage tank. The hydrogen is used to produce electricity in a fuel cell in order to meet the above mentioned heat pump power demand when the photovoltaic system is inactive during winter night-time or the solar radiation level is insufficient to meet the electrical demand. The present work reports some theoretical and observed data about the electrolyzer operation. Indeed the electrolyzer has required particular attention because during the experimental tests it did not show a stable operation and it was registered a performance not properly consistent with the predicted performance by means of the theoretical study.

  20. Investigation of the heat source(s) of the Surprise Valley Geothermal System, Northern California

    Science.gov (United States)

    Tanner, N.; Holt, C. D.; Hawkes, S.; McClain, J. S.; Safford, L.; Mink, L. L.; Rose, C.; Zierenberg, R. A.

    2016-12-01

    Concerns about environmental impacts and energy security have led to an increased interest in sustainable and renewable energy resources, including geothermal systems. It is essential to know the permeability structure and possible heat source(s) of a geothermal area in order to assess the capacity and extent of the potential resource. We have undertaken geophysical surveys at the Surprise Valley Hot Springs in Cedarville, California to characterize essential parameters related to a fault-controlled geothermal system. At present, the heat source(s) for the system are unknown. Igneous bodies in the area are likely too old to have retained enough heat to supply the system, so it is probable that fracture networks provide heat from some deeper or more distributed heat sources. However, the fracture system and permeability structure remain enigmatic. The goal of our research is to identify the pathways for fluid transport within the Surprise Valley geothermal system using a combination of geophysical methods including active seismic surveys and short- and long-period magnetotelluric (MT) surveys. We have collected 14 spreads, consisting of 24 geophones each, of active-source seismic data. We used a "Betsy Gun" source at 8 to 12 locations along each spread and have collected and analyzed about 2800 shot-receiver pairs. Seismic velocities reveal shallow lake sediments, as well as velocities consistent with porous basalts. The latter, with velocities of greater than 3.0 km/s, lie along strike with known hot springs and faulted and tilted basalt outcrops outside our field area. This suggests that basalts may provide a permeable pathway through impermeable lake deposits. We conducted short-period (10Hz-60kHz) MT measurements at 33 stations. Our short-period MT models indicate shallow resistive blocks (>100Ωm) with a thin cover of more conductive sediments ( 10Ωm) at the surface. Hot springs are located in gaps between resistive blocks and are connected to deeper low

  1. Integrated Temperature Sensors based on Heat Diffusion

    NARCIS (Netherlands)

    Van Vroonhoven, C.P.L.

    2015-01-01

    This thesis describes the theory, design and implementation of a new class of integrated temperature sensors, based on heat diffusion. In such sensors, temperature is sensed by measuring the time it takes for heat to diffuse through silicon. An on-chip thermal delay can be determined by geometry and

  2. ELM simulation experiments on Pilot-PSI using simultaneous high flux plasma and transient heat/particle source

    NARCIS (Netherlands)

    De Temmerman, G.; Zielinski, J. J.; van Diepen, S.; Marot, L.; Price, M.

    2011-01-01

    A new experimental setup has been developed for edge localized mode (ELM) simulation experiments with relevant steady-state plasma conditions and transient heat/particle source. The setup is based on the Pilot-PSI linear plasma device and allows the superimposition of a transient heat/particle pulse

  3. Design and qualification testing of a strontium-90 fluoride heat source

    Energy Technology Data Exchange (ETDEWEB)

    Fullam, H.T.

    1981-12-01

    The Strontium Heat Source Development Program began at the Pacific Northwest Laboratory (PNL) in 1972 and is scheduled to be completed by the end of FY-1981. The program is currently funded by the US Department of Energy (DOE) By-Product Utilization Program. The primary objective of the program has been to develop the data and technology required to permit the licensing of power systems for terrestrial applications that utilize /sup 90/SrF/sub 2/-fueled radioisotope heat sources. A secondary objective of the program has been to design and qualification-test a general purpose /sup 90/SrF/sub 2/-fueled heat source. The effort expended in the design and testing of the heat source is described. Detailed information is included on: heat source design, licensing requirements, and qualification test requirements; the qualification test procedures; and the fabrication and testing of capsules of various materials. The results obtained in the qualification tests show that the outer capsule design proposed for the /sup 90/SrF/sub 2/ heat source is capable of meeting current licensing requirements when Hastelloy S is used as the outer capsule material. The data also indicate that an outer capsule of Hastelloy C-4 would probably also meet licensing requirements, although Hastelloy S is the preferred material. Therefore, based on the results of this study, the general purpose /sup 90/SrF/sub 2/ heat source will consist of a standard WESF Hastelloy C-276 inner capsule filled with /sup 90/SrF/sub 2/ and a Hastelloy S outer capsule having a 2.375-in. inner diameter and 0.500-in. wall thickness. The end closures for this study, the general purpose /sup 90/SrF/sub 2/ heat a Hastelloy S outer capsule having a 2.375-in. inner diameter and 0.500-in. wall thickness. The end closures for the outer capsule will utilize an interlocking joint design requiring a 0.1-in. penetration closure weld. (LCL)

  4. Characterizing open and non-uniform vertical heat sources: towards the identification of real vertical cracks in vibrothermography experiments

    Science.gov (United States)

    Castelo, A.; Mendioroz, A.; Celorrio, R.; Salazar, A.; López de Uralde, P.; Gorosmendi, I.; Gorostegui-Colinas, E.

    2017-05-01

    Lock-in vibrothermography is used to characterize vertical kissing and open cracks in metals. In this technique the crack heats up during ultrasound excitation due mainly to friction between the defect's faces. We have solved the inverse problem, consisting in determining the heat source distribution produced at cracks under amplitude modulated ultrasound excitation, which is an ill-posed inverse problem. As a consequence the minimization of the residual is unstable. We have stabilized the algorithm introducing a penalty term based on Total Variation functional. In the inversion, we combine amplitude and phase surface temperature data obtained at several modulation frequencies. Inversions of synthetic data with added noise indicate that compact heat sources are characterized accurately and that the particular upper contours can be retrieved for shallow heat sources. The overall shape of open and homogeneous semicircular strip-shaped heat sources representing open half-penny cracks can also be retrieved but the reconstruction of the deeper end of the heat source loses contrast. Angle-, radius- and depth-dependent inhomogeneous heat flux distributions within these semicircular strips can also be qualitatively characterized. Reconstructions of experimental data taken on samples containing calibrated heat sources confirm the predictions from reconstructions of synthetic data. We also present inversions of experimental data obtained from a real welded Inconel 718 specimen. The results are in good qualitative agreement with the results of liquids penetrants testing.

  5. 基于不同可调度热源的风电出力平滑模型%Model of smoothing wind power based on various dispatchable heat sources

    Institute of Scientific and Technical Information of China (English)

    严旭; 吴锴; 周孟戈; 印华; 杨玉龙; 高健超

    2013-01-01

    风能具有随机性和间歇性,导致风电出力具有波动性。计及供暖热源机组爬坡速率、发电出力与供暖出力间约束以及热源距离用户的供暖热水管道距离等因素,以等效风电出力波动最小为目标函数,建立基于不同热源机组的风电出力平滑模型。提出利用电力热泵作为补偿热源,将爬坡速率作为热源机组进行出力调节的响应约束,同时将热源距离用户的供暖热水管道距离转化为热水输送时间,作为风电出力调度的关键参量。模拟计算表明:1)新型风电出力调度方法可以有效平滑风电出力;2)基于不同热源的风电平滑效果存在差异,使用抽凝式热电联产机组的调节效果最好,等效风电出力波动接近于零。%Intermittence and volatility of wind result in the fluctuation of wind power. Considering the climbing rates and the heat-power feasible operation region of different heat sources and the distance between heat sources and end users, mathematical models of wind power dispatch with different heat sources are established, where minimum fluctuations of equivalent wind power are performed as the objective function. This paper puts forward electric heat pumps as additional heat sources for space heating purpose and the climbing rates as the restrict of power adjustments for heat sources, and proposes to switch the pipeline distance of hot water between heat sources and end users into transportation time cost for wind power dispatch as a key parameter. Through the numerical simulation it is revealed that:1) wind power smoothness can be achieved effectively utilizing this novel wind power dispatch method;2) three kinds of heat sources have different influences on the smoothness of wind power. With the extraction-condensing cogeneration units as heat source, the standard deviation of the regulated wind power is almost zero, which is treated as the best result.

  6. Using Ground Source Heat Pumps for Renewable Energy

    Directory of Open Access Journals (Sweden)

    Xhevat BERISHA

    2017-04-01

    Full Text Available This paper provides background information on the current energy supply, energy demand, and energy sources in Kosovo. Moreover, it presents the country‟s current level of applying alternative energy sources. Additionally, this paper focuses on geothermal energy as a renewable energy resource with the potential to contribute to a sustainable use of resources to meet renewable energy and energy efficiency requirements of the European Union (EU, “EU 20 20 by 2020” policy. Hence, a careful analysis is included on how to approach the aforementioned targets through investments in geothermal energy through providing an energy consumption forecast and analysing geothermal energy projects in Europe and specifically in Kosovo. This paper carefully represents the potential usage of geothermal energy in Kosovo, renewable energy source targets, and it addresses the importance of laws, regulations, and reports regarding the utilization of this type of energy. Economic and environmental implications of investing in geothermal energy - geothermal heat pumps for the case of International Village are additionally analysed. Lastly, recommendations and conclusions, for future actions, are derived and addressed to relevant stakeholders, primarily policy-makers, and government representatives.

  7. Nanofluid flow and forced convection heat transfer over a stretching surface considering heat source

    Science.gov (United States)

    Mohammadpour, M.; Valipour, P.; Shambooli, M.; Ayani, M.; Mirparizi, M.

    2015-07-01

    In this paper, magnetic field effects on the forced convection flow of a nanofluid over a stretching surface in the presence of heat generation/absorption are studied. The equations of continuity, momentum and energy are transformed into ordinary differential equations and solved numerically using the fourth-order Runge-Kutta integration scheme featuring the shooting technique. Different types of nanoparticles as copper (Cu), silver (Ag), alumina (Al2O3) and titania (TiO2) with water as their base fluid has been considered. The influence of significant parameters, such as magnetic parameter, volume fraction of the nanoparticles, heat generation/absorption parameter, velocity ratio parameter and temperature index parameter on the flow and heat transfer characteristics are discussed. The results show that the values of temperature profiles increase with increasing heat generation/absorption and volume fraction of the nanoparticles but they decrease with increasing velocity ratio parameter and temperature index parameter. Also, it can be found that selecting silver as nanoparticle leads to the highest heat transfer enhancement.

  8. Optimization for Complex System of Ground Source Heat Pump Based on TRNSYS%基于 TRNSYS 的地源热泵复合系统运行策略的优化

    Institute of Scientific and Technical Information of China (English)

    程晓曼; 刘金祥; 陈高峰; 李帅

    2015-01-01

    TRNSYS is utilized to establish the composite system model of ground source heat pump and cooling tower, and simulate running situation of the composite ground source heat pump system in of-fice building for a long time in the hot summer and cold winter region. On the basis of theoretical analysis and the measured data validation, considering weather conditions, cooling tower open time, soil factors such as heat dissipation, the paper analyzes the joint operation characteristics of cooling tower and the ground source heat pump in local office building. Opening the cooling tower at night with normal operation mode of the ground source heat pump during the day is proposed for office building in the refrigeration period.%利用 TRNSYS 瞬时仿真模拟软件建立地源热泵与冷却塔复合系统模型,模拟出夏热冬冷地区办公楼地源热泵复合系统长期运行情况。在理论分析和实测数据验证的基础上,考虑气象条件、冷却塔开启时间、土壤散热等因素,分析该地区办公建筑冷却塔与地源热泵联合运行的特点;提出制冷期办公建筑夜间开启冷却塔蓄冷、白天地源热泵正常运行的模式。

  9. Ground heat flux and power sources of low-enthalpy geothermal systems

    Science.gov (United States)

    Bayer, Peter; Blum, Philipp; Rivera, Jaime A.

    2015-04-01

    Geothermal heat pumps commonly extract energy from the shallow ground at depths as low as approximately 400 m. Vertical borehole heat exchangers are often applied, which are seasonally operated for decades. During this lifetime, thermal anomalies are induced in the ground and surface-near aquifers, which often grow over the years and which alleviate the overall performance of the geothermal system. As basis for prediction and control of the evolving energy imbalance in the ground, focus is typically set on the ground temperatures. This is reflected in regulative temperature thresholds, and in temperature trends, which serve as indicators for renewability and sustainability. In our work, we examine the fundamental heat flux and power sources, as well as their temporal and spatial variability during geothermal heat pump operation. The underlying rationale is that for control of ground temperature evolution, knowledge of the primary heat sources is fundamental. This insight is also important to judge the validity of simplified modelling frameworks. For instance, we reveal that vertical heat flux from the surface dominates the basal heat flux towards a borehole. Both fluxes need to be accounted for as proper vertical boundary conditions in the model. Additionally, the role of horizontal groundwater advection is inspected. Moreover, by adopting the ground energy deficit and long-term replenishment as criteria for system sustainability, an uncommon perspective is adopted that is based on the primary parameter rather than induced local temperatures. In our synthetic study and dimensionless analysis, we demonstrate that time of ground energy recovery after system shutdown may be longer than what is expected from local temperature trends. In contrast, unrealistically long recovery periods and extreme thermal anomalies are predicted without account for vertical ground heat fluxes and only when the energy content of the geothermal reservoir is considered.

  10. Water source heat pumps for greenhouse soil cooling. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Spieser, H.

    1987-06-01

    In an attempt to diversify and grow flowers which are in high demand, growers are looking to produce certain exotic flowers which require unique growing conditions. One example is the Alstroemerias also knwon as the Peruvian Lily. If the plants are grown continuously at about 12-15/sup 0/C soil temperature, the plant will continue to flower regardless of air temperature and photoriod. These latter two factors are considered secondary to the importance of cool soil temperatures. Alstroemeria production is still relatively new to the greenhouse industry. Some controversy still exists as to the direct benefits of planned soil cooling. This project was set up to evaluate a mechanical soil cooling system for continuous year round Alstroemeria production. A heat pump soil cooling system was installed in two greenhouses each with dimensions of 16 m by 61 m. Combined these greenhouses have a growing area of 1952 m/sup 2/. These greenhouses are older wooden greenhouses, covered by double poly, air-inflated glazing. This system worked very well, maintaining the soil temperature at the proper levels throughout the spring and summer months. During the rest of the year the soil cooling system is used less intensely. During winter months when soil cooling is not required, the heat pumps provide base load heating to the greenhouse through fan forced unit heaters.

  11. Combined radiative and natural or forced convective heat transfer between parallel vertical plates with two-dimensional discrete heat sources

    Energy Technology Data Exchange (ETDEWEB)

    Nickell, T.W.

    1988-01-01

    This study numerically analyzes combined radiative and natural or forced convective heat transfer between vertical parallel plates with two-dimensional discrete heat sources. The numerical method was verified by comparing its results with other published experimental data and the agreement was excellent. It is shown that radiative heat transfer is a significant and useful mode of heat transfer in combination with both natural and forced convection in this situation and cannot be neglected. Radiative heat transfer accounted for 50-60% or more of the total heat transfer in some cases, and usually approximately 30-35% on the top of a discrete heat source. This fact can be used to advantage in the thermal design of electronic circuit boards.

  12. The impact of in-canopy wind profile formulations on heat flux estimation using the remote sensing-based two-source model for an open orchard canopy in southern Italy

    Directory of Open Access Journals (Sweden)

    C. Cammalleri

    2010-07-01

    Full Text Available For open orchard and vineyard canopies containing significant fractions of exposed soil (>50%, typical of Mediterranean agricultural regions, the energy balance of the vegetation elements is strongly influenced by heat exchange with the bare soil/substrate. For these agricultural systems a "two-source" approach, where radiation and turbulent exchange between the soil and canopy elements are explicitly modelled, appears to be the only suitable methodology for reliably assessing energy fluxes. In strongly clumped canopies, the effective wind speed profile inside and below the canopy layer can highly influence the partitioning of energy fluxes between the soil and vegetation components. To assess the impact of in-canopy wind profile on model flux estimates, an analysis of three different formulations is presented, including algorithms from Goudriaan (1977, Massman (1987 and Lalic et al. (2003. The in-canopy wind profile formulations are applied to the thermal-based Two-Source Energy Balance (TSEB model developed by Norman et al. (1995 and modified by Kustas and Norman (1999. High resolution airborne remote sensing images, collected over an agricultural area located in the western part of Sicily (Italy comprised primarily of vineyards, olive and citrus orchards, are used to derive all the input parameters need to apply the TSEB. The images were acquired from June to October 2008 and include a relatively wide range of meteorological and soil moisture conditions. A preliminary sensitivity analysis of the three wind profile algorithms highlight the dependence of wind speed just above the soil/substrate to leaf area index and canopy height over the typical canopy properties range of these agricultural area. It is found that differences in wind just above surface among the models is most significant under sparse and medium fractional cover conditions (20–60%. The TSEB model heat flux estimates are compared with micrometeorological measurements from a

  13. Comparison on welding mode characteristics of arc heat source for heat input control in hybrid welding of aluminum alloy

    Science.gov (United States)

    Song, Moo-Keun; Kim, Jong-Do; Oh, Jae-Hwan

    2015-03-01

    Presently in shipbuilding, transportation and aerospace industries, the potential to apply welding using laser and laser-arc hybrid heat sources is widely under research. This study has the purpose of comparing the weldability depending on the arc mode by varying the welding modes of arc heat sources in applying laser-arc hybrid welding to aluminum alloy and of implementing efficient hybrid welding while controlling heat input. In the experimental study, we found that hybrid welding using CMT mode produced deeper penetration and sounder bead surface than those characteristics produced during only laser welding, with less heat input compared to that required in pulsed arc mode.

  14. Optimal design of district heating and cooling pipe network of seawater-source heat pump

    Energy Technology Data Exchange (ETDEWEB)

    Li, Xiang-li; Duanmu, Lin; Shu, Hai-wen [School of Civil and Hydraulic Engineering, Dalian University of Technology, Dalian, Liaoning Province 116024 (China)

    2010-01-15

    The district heating and cooling (DHC) system of a seawater-source heat pump is large system engineering. The investments and the operational cost of DHC pipe network are higher than a tradition system. Traditional design methods only satisfy the needs of the technology but dissatisfy the needs of the economy, which not only waste a mass of money but also bring problems to the operation, the maintenance and the management. So we build a least-annualized-cost global optimal mathematic model that comprises all constrict conditions. Furthermore, this model considers the variety of heating load and cooling load, the operational adjustment in different periods of the year. Genetic algorithm (GA) is used to obtain the optimal combinations of discrete diameters. Some operators of GA are selected to reduce the calculation time and obtain good calculation accuracy. This optimal method is used to the design of the DHC network of Xinghai Bay commercial district which is a real engineering. The design optimization can avoid the matter of the hydraulic unbalance of the system, enhance the running efficiency and greatly reduce the annualized-cost comparing with the traditional design method. (author)

  15. Measured Performance of a Low Temperature Air Source Heat Pump

    Energy Technology Data Exchange (ETDEWEB)

    R.K. Johnson

    2013-09-01

    A 4-ton Low Temperature Heat Pump (LTHP) manufactured by Hallowell International was installed in a residence near New Haven, Connecticut and monitored over two winters of operation. After attending to some significant service issues, the heat pump operated as designed. This report should be considered a review of the dual compressor “boosted heat pump” technology. The Low Temperature Heat Pump system operates with four increasing levels of capacity (heat output) as the outdoor temperature drops.

  16. Assessment of heat sources on the control of fast flow of Vestfonna Ice Cap, Svalbard

    Directory of Open Access Journals (Sweden)

    M. Schäfer

    2013-10-01

    Full Text Available The dynamic regime of Svalbard's Nordaustlandet ice caps is dominated by fast flowing outlet glaciers, making assessment of their response to climate change challenging. A key element of the challenge lies in the fact that the motion of fast outlet glaciers occurs largely through basal sliding, and is governed by physical processes at the glacier bed, processes that are difficult both to observe and to simulate. Up to now, most of the sliding laws used in ice flow models were based on uniform parameters with a condition on temperature to identify regions of basal sliding. However these models are usually not able to reproduce observed velocities with sufficient accuracy. With the development of inverse methods, it is now common to infer a spatially varying field of sliding parameters from surface ice-velocity observations. These parameter distributions usually reflect a high spatial variability and represent valuable information to understand and test various hypotheses on physical processes involved in sliding. However, in these models, basal sliding is uncoupled from the thermal regime of basal ice and the evolution of the sliding parameters in prognostic simulations remains problematic. Here we explore the role of different heat sources (friction heating, strain heating and latent heat through percolation of melt water on the development of sliding and fast flow through thermomechanical coupling on Nordaustlandet outlet glaciers. We focus on Vestfonna with a special emphasis on Franklinbreen, a fast flowing outlet glacier which has been observed to accelerate between 1995 and 2008 and possibly already prior to 1995. We try to reconcile the impacts of temperature and heat sources on basal friction coefficients inferred from observed surface velocities during these two periods. Our simulations reproduce a temperature profile from borehole measurements, allowing an interpretation of the vertical temperature structure in terms of temporal

  17. About the possible options for models of convective heat transfer in closed volumes with local heating source

    Directory of Open Access Journals (Sweden)

    Maksimov Vyacheslav I.

    2015-01-01

    Full Text Available Results of mathematical modeling of convective heat transfer in air area surrounded on all sides enclosing structures, in the presence of heat source at the lower boundary of the media are presented. Solved the system of differential equations of unsteady Navier-Stokes equations with the appropriate initial and boundary conditions. The process of convective heat transfer is calculated using the models of turbulence Prandtl and Prandtl-Reichard. Takes into account the processes of heat exchange region considered with the environment. Is carried out the analysis of the dimensionless heat transfer coefficient at interfaces “air – enclosures”. The distributions average along the gas temperature range are obtained.

  18. Assessment of heat sources on the control of fast flow of Vestfonna ice cap, Svalbard

    Science.gov (United States)

    Schäfer, M.; Gillet-Chaulet, F.; Gladstone, R.; Pettersson, R.; Pohjola, V. A.; Strozzi, T.; Zwinger, T.

    2014-10-01

    Understanding the response of fast flowing ice streams or outlet glaciers to changing climate is crucial in order to make reliable projections of sea level change over the coming decades. Motion of fast outlet glaciers occurs largely through basal motion governed by physical processes at the glacier bed, which are not yet fully understood. Various subglacial mechanisms have been suggested for fast flow but common to most of the suggested processes is the requirement of presence of liquid water, and thus temperate conditions. We use a combination of modelling, field, and remote observations in order to study links between different heat sources, the thermal regime and basal sliding in fast flowing areas on Vestfonna ice cap. A special emphasis lies on Franklinbreen, a fast flowing outlet glacier which has been observed to accelerate recently. We use the ice flow model Elmer/Ice including a Weertman type sliding law and a Robin inverse method to infer basal friction parameters from observed surface velocities. Firn heating, i.e. latent heat release through percolation of melt water, is included in our model; its parameterisation is calibrated with the temperature record of a deep borehole. We found that strain heating is negligible, whereas friction heating is identified as one possible trigger for the onset of fast flow. Firn heating is a significant heat source in the central thick and slow flowing area of the ice cap and the essential driver behind the ongoing fast flow in all outlets. Our findings suggest a possible scenario of the onset and maintenance of fast flow on the Vestfonna ice cap based on thermal processes and emphasise the role of latent heat released through refreezing of percolating melt water for fast flow. However, these processes cannot yet be captured in a temporally evolving sliding law. In order to simulate correctly fast flowing outlet glaciers, ice flow models not only need to account fully for all heat sources, but also need to incorporate

  19. Lunar base heat pump, phase 1

    Science.gov (United States)

    Goldman, Jeffrey H.; Harvey, A.; Lovell, T.; Walker, David H.

    1994-01-01

    This report describes the Phase 1 process and analysis used to select a refrigerant and thermodynamic cycle as the basis of a vapor compression heat pump requiring a high temperature lift, then to perform a preliminary design to implement the selected concept, including major component selection. Use of a vapor compression heat pump versus other types was based on prior work performed for the Electric Power Research Institute. A high lift heat pump is needed to enable a thermal control system to remove heat down to 275 K from a habitable volume when the external thermal environment is severe. For example, a long-term lunar base habitat will reject heat from a space radiator to a 325 K environment. The first step in the selection process was to perform an optimization trade study, quantifying the effect of radiator operating temperature and heat pump efficiency on total system mass; then, select the radiator operating temperature corresponding to the lowest system mass. Total system mass included radiators, all heat pump components, and the power supply system. The study showed that lunar night operation, with no temperature lift, dictated the radiator size. To operate otherwise would require a high mass penalty to store power. With the defined radiation surface, and heat pump performances assumed to be from 40 percent to 60 percent of the Carnot ideal, the optimum heat rejection temperature ranged from 387 K to 377 K, as a function of heat pump performance. Refrigerant and thermodynamic cycles were then selected to best meet the previously determined design conditions. The system was then adapted as a ground-based prototype lifting temperature to 360 K (versus 385 K for flight unit) and using readily available commercial-grade components. Over 40 refrigerants, separated into wet and dry compression behavioral types, were considered in the selection process. Refrigerants were initially screened for acceptable critical temperature. The acceptable refrigerants were

  20. COMPARATIVE STUDY AMONG HYBRID GROUND SOURCE HEAT PUMP SYSTEM, COMPLETE GROUND SOURCE HEAT PUMP AND CONVENTIONAL HVAC SYSTEM

    Energy Technology Data Exchange (ETDEWEB)

    Jiang Zhu; Yong X. Tao

    2011-11-01

    In this paper, a hotel with hybrid geothermal heat pump system (HyGSHP) in the Pensacola is selected and simulated by the transient simulation software package TRNSYS [1]. To verify the simulation results, the validations are conducted by using the monthly average entering water temperature, monthly facility consumption data, and etc. And three types of HVAC systems are compared based on the same building model and HVAC system capacity. The results are presented to show the advantages and disadvantages of HyGSHP compared with the other two systems in terms of energy consumptions, life cycle cost analysis.

  1. Allothermal gasification of biomass using micron size biomass as external heat source.

    Science.gov (United States)

    Cheng, Gong; Li, Qian; Qi, Fangjie; Xiao, Bo; Liu, Shiming; Hu, Zhiquan; He, Piwen

    2012-03-01

    An allothermal biomass gasification system using biomass micron fuel (BMF) as external heat source was developed. In this system, heat supplied to gasifier was generated from combustion of BMF. Biomass feedstock was gasified with steam and then tar in the produced gas was decomposed in a catalytic bed with NiO/γ-Al(2)O(3) catalyst. Finally the production gas was employed as a substitute for civil fuel gas. An overall energy analysis of the system was also investigated. The results showed that the lower heating value of the product gas reached more than 12 MJ/Nm(3). The combusted BMF accounted for 26.8% of the total energy input. Allothermal gasification based on the substituted BMF for conventional energy was an efficient and economical technology to obtain bioenergy.

  2. Temperature distribution of air source heat pump barn with different air flow

    Science.gov (United States)

    He, X.; Li, J. C.; Zhao, G. Q.

    2016-08-01

    There are two type of airflow form in tobacco barn, one is air rising, the other is air falling. They are different in the structure layout and working principle, which affect the tobacco barn in the distribution of temperature field and velocity distribution. In order to compare the temperature and air distribution of the two, thereby obtain a tobacco barn whose temperature field and velocity distribution are more uniform. Taking the air source heat pump tobacco barn as the investigated subject and establishing relevant mathematical model, the thermodynamics of the two type of curing barn was analysed and compared based on Fluent. Provide a reasonable evidence for chamber arrangement and selection of outlet for air source heat pump tobacco barn.

  3. Hourly Calculation Method of Air Source Heat Pump Behavior

    Directory of Open Access Journals (Sweden)

    Ludovico Danza

    2016-04-01

    Full Text Available The paper describes an hourly simplified model for the evaluation of the energy performance of heat pumps in cooling mode maintaining a high accuracy and low computational cost. This approach differs from the methods used for the assessment of the overall energy consumption of the building, normally placed in the so-called white or black box models, where the transient conduction equation is deterministically and stochastically solved, respectively. The present method wants to be the expression of the grey box model, taking place between the previous approaches. The building envelope is defined using a building thermal model realized with a 3 Resistance 1 Capacitance (3R1C thermal network based on the solution of the lumped capacitance method. The simplified model evaluates the energy efficiency ratio (EER of a heat pump through the determination of the hourly second law efficiency of a reversed Carnot cycle. The results of the simplified method were finally compared with those provided by EnergyPlus, a dynamic building energy simulation program, and those collected from an outdoor test cell in real working conditions. The results are presented in temperatures and energy consumptions profiles and are validated using the Bland-Altman test.

  4. Analysis of classical Fourier, SPL and DPL heat transfer model in biological tissues in presence of metabolic and external heat source

    Science.gov (United States)

    Kumar, Dinesh; Singh, Surjan; Rai, K. N.

    2016-06-01

    In this paper, the temperature distribution in a finite biological tissue in presence of metabolic and external heat source when the surface subjected to different type of boundary conditions is studied. Classical Fourier, single-phase-lag (SPL) and dual-phase-lag (DPL) models were developed for bio-heat transfer in biological tissues. The analytical solution obtained for all the three models using Laplace transform technique and results are compared. The effect of the variability of different parameters such as relaxation time, metabolic heat source, spatial heat source, different type boundary conditions on temperature distribution in different type of the tissues like muscle, tumor, fat, dermis and subcutaneous based on three models are analyzed and discussed in detail. The result obtained in three models is compared with experimental observation of Stolwijk and Hardy (Pflug Arch 291:129-162, 1966). It has been observe that the DPL bio-heat transfer model provides better result in comparison of other two models. The value of metabolic and spatial heat source in boundary condition of first, second and third kind for different type of thermal therapies are evaluated.

  5. local alternative sources for cogeneration combined heat and power system

    Science.gov (United States)

    Agll, Abdulhakim Amer

    Global demand for energy continues to grow while countries around the globe race to reduce their reliance on fossil fuels and greenhouse gas emissions by implementing policy measures and advancing technology. Sustainability has become an important issue in transportation and infrastructure development projects. While several agencies are trying to incorporate a range of sustainability measures in their goals and missions, only a few planning agencies have been able to implement these policies and they are far from perfect. The low rate of success in implementing sustainable policies is primarily due to incomplete understanding of the system and the interaction between various elements of the system. The conventional planning efforts focuses mainly on performance measures pertaining to the system and its impact on the environment but seldom on the social and economic impacts. The objective of this study is to use clean and alternative energy can be produced from many sources, and even use existing materials for energy generation. One such pathway is using wastewater, animal and organic waste, or landfills to create biogas for energy production. There are three tasks for this study. In topic one evaluated the energy saving that produced from combined hydrogen, heat, and power and mitigate greenhouse gas emissions by using local sustainable energy at the Missouri S&T campus to reduce energy consumption and fossil fuel usage. Second topic aimed to estimate energy recovery and power generation from alternative energy source by using Rankin steam cycle from municipal solid waste at Benghazi-Libya. And the last task is in progress. The results for topics one and two have been presented.

  6. Heat Transfer in MHD Dusty Boundary Layer Flow over an Inclined Stretching Sheet with Non-Uniform Heat Source/Sink

    Directory of Open Access Journals (Sweden)

    G. K. Ramesh

    2012-01-01

    Full Text Available This paper presents the study of momentum and heat transfer characteristics in a hydromagnetic flow of dusty fluid over an inclined stretching sheet with non-uniform heat source/sink, where the flow is generated due to a linear stretching of the sheet. Using a similarity transformation, the governing equations of the problem are reduced to a coupled third-order nonlinear ordinary differential equations and are solved numerically by Runge-Kutta-Fehlberg fourth-fifth-order method using symbolic software Maple. Our numerical solutions are shown to agree with the available results in the literature and then employ the numerical results to bring out the effects of the fluid-particle interaction parameter, local Grashof number, angle of inclination, heat source/sink parameter, Chandrasekhar number, and the Prandtl number on the flow and heat transfer characteristics. The results have possible technological applications in liquid-based systems involving stretchable materials.

  7. 基于Monte Carlo方法的压水堆相关组件内热源计算与分析%Calculation and analysis of heat source of PWR assemblies based on Monte Carlo method

    Institute of Scientific and Technical Information of China (English)

    胡也; 陈义学; 杨寿海; 靳忠敏

    2013-01-01

    When fission occurs in nuclear fuel in reactor core,it releases numerous neutron and γ radiation,which takes energy deposition in fuel components and yields many factors such as thermal stressing and radiation damage influencing the safe operation of a reactor.Using the three-dimensional Monte Carlo transport calculation program MCNP and continuous crosssection database based on ENDF/B series to calculate the heat rate of the heat source on reference assemblies of a PWR when loading with 18-month short refueling cycle mode,and get the precise values of the control rod,thimble plug and new burnable poison rod within Gd,so as to provide basis for reactor design and safety verification.%堆芯中核燃料发生裂变时,伴随产生极强的中子及γ辐射,这些辐射在燃料组件中发生能量沉积,产生热应力、辐照损伤等诸多影响反应堆安全运行的因素.尤其对于新型含钆可燃毒物棒组件,国内对此方面的研究需要进一步开展.采用三维蒙特卡罗输运计算程序MCNP和基于ENDF/B的连续截面数据库,对压水堆18个月长、短周期装料方式的堆芯相关组件内热源的释热率分布进行详细计算,计算得出控制棒、阻力塞棒和新型含钆可燃毒物棒释热率精确计算值,并对不同版本数据库中部分关键核素截面对计算结果的影响进行比较分析,为核反应堆堆芯设计提供参考.

  8. Conduction heat transfer in semi-infinite and infinite regions with discrete heat sources

    Energy Technology Data Exchange (ETDEWEB)

    Venkataraman, Nellore S.; Castillo, Omar E. Meza [Puerto Rico Univ., Dept. of Mechanical Engineering, Mayaguez (Puerto Rico)

    2006-01-15

    The steady state temperature distribution in semi-infinite slabs and infinite quadrants due to two- and three-dimensional discrete heating sources shaped in the form of thin electric current carrying wires has been determined. The temperature field is obtained using Green's function integral techniques. The solutions obtained here are compared with numerical solutions obtained from a commercial software package. It is shown that for the cases considered here we get closed form solutions or solutions in the form of simple numerically calculable integrals which are far superior to numerical methods in terms of elegance and labor involved for parametric studies. The behavior of the non-dimensional temperature with the various relevant parameters is discussed. (Author)

  9. 太阳能-空气复合热源热泵热水系统%Solar-air composite heat source heat pump hot water system

    Institute of Scientific and Technical Information of China (English)

    王岗; 全贞花; 赵耀华; 侯隆澍; 徐俊芳; 邓月超

    2014-01-01

    In the light of low efficiency of photovoltaic power generation and the problems of air source heat pump applied in cold regions, a composite heat exchanger evaporator is developed and a new type of solar-air composite heat source heat pump hot water system is designed in this study, which is comprised of independent solar photovoltaic-thermal collector based on flat plate micro heat pipe and air source heat pump. The performance of heat pump hot water system is evaluated experimentally under different operating conditions, including water temperature of the tank, heating time of hot water, suction and discharge pressure, consumption of compressor power and heat pump coefficient of performance (COP), etc. Experimental results show that at ambient temperature of 5℃, 10℃ and 15℃, with 73 L hot water heated by heat pump and water temperature in the tank ranged from 15℃ to 50℃, the running time of composite heat source operation is shorter than that of separate air heat source operation, decreased by 5.14%, 10.29% and 11.38%, respectively. COPs are increased by 5.99%, 9.28%and 11.96%, respectively.%针对光伏发电效率较低和空气源热泵在寒冷地区应用中存在的问题,研发了一种新型复合蒸发器,将平板微热管阵列太阳能光伏光热(PV/T)集热器与空气源热泵相结合,组成新型太阳能-空气复合热源热泵热水系统。并对该热水系统在不同运行工况下的水箱水温、吸排气压力、压缩机功率和性能等进行了实验研究。实验结果表明,在环境温度分别为5、10和15℃的条件下,热泵加热73 L水,水温从15℃加热到50℃时,双热源运行工况的加热时间比单空气热源运行工况依次缩短了5.14%、10.29%和11.38%,COP依次提高了5.99%、9.28%和11.96%。

  10. Forecast of power generation and heat production from renewable energy sources

    Directory of Open Access Journals (Sweden)

    Pydych Tadeusz

    2017-01-01

    Full Text Available The share of renewable energy sources (RES in the end use of energy in the UE will increase from the present level of about 25% to 50 % in 2030 according to the assumptions of the European Commission. In Poland the RES Act was passed in 2015. The act defines mechanisms and instruments for supporting the production of electricity and heat from renewable energy sources. Statistics (2003–2014 of electricity generation and heat production from RES in Poland were used in the research. Because of amendments to regulations connected with promoting RES and the emissions trading system (ETS as well as the uncertainty associated with further directions of the energy and environmental policy, generation of electricity and heat based on the use of RES must be modelled while taking risk into account. A number of dynamic processes incorporating random events may be modelled by stochastic equations using Ito calculus. By applying Euler’s method to solve stochastic differential equations (SDE, it is possible to simulate the development of the use of renewable energy carriers in electricity generation and heat production in the future.

  11. Harvesting Nanocatalytic Heat Localized in Nanoalloy Catalyst as a Heat Source in a Nanocomposite Thin Film Thermoelectric Device.

    Science.gov (United States)

    Zhao, Wei; Shan, Shiyao; Luo, Jin; Mott, Derrick M; Maenosono, Shinya; Zhong, Chuan-Jian

    2015-10-20

    This report describes findings of an investigation of harvesting nanocatalytic heat localized in a nanoalloy catalyst layer as a heat source in a nanocomposite thin film thermoelectric device for thermoelectric energy conversion. This device couples a heterostructured copper-zinc sulfide nanocomposite for thermoelectrics and low-temperature combustion of methanol fuels over a platinum-cobalt nanoalloy catalyst for producing heat localized in the nanocatalyst layer. The possibility of tuning nanocatalytic heat in the nanocatalyst and thin film thermoelectric properties by compositions points to a promising pathway in thermoelectric energy conversion.

  12. Climate Adaptivity and Field Test of the Space Heating Used Air-Source Transcritical CO2 Heat Pump

    Science.gov (United States)

    Song, Yulong; Ye, Zuliang; Cao, Feng

    2017-08-01

    In this study, an innovation of air-sourced transcritical CO2 heat pump which was employed in the space heating application was presented and discussed in order to solve the problem that the heating performances of the transcritical CO2 heat pump water heater deteriorated sharply with the augment in water feed temperature. An R134a cycle was adopted as a subcooling device in the proposed system. The prototype of the presented system was installed and supplied hot water for three places in northern China in winter. The field test results showed that the acceptable return water temperature can be increased up to 55°C, while the supply water temperature was raised rapidly by the presented prototype to up to 70°C directly, which was obviously appropriate to the various conditions of heating radiator in space heating application. Additionally, though the heating capacity and power dissipation decreased with the decline in ambient temperature or the augment in water temperature, the presented heat pump system performed efficiently whatever the climate and water feed temperature were. The real time COP of the presented system was generally more than 1.8 in the whole heating season, while the seasonal performance coefficient (SPC) was also appreciable, which signified that the economic efficiency of the presented system was more excellent than other space heating approaches such as fuel, gas, coal or electric boiler. As a result, the novel system will be a promising project to solve the energy issues in future space heating application.

  13. Investigation of direct expansion in ground source heat pumps

    Science.gov (United States)

    Kalman, M. D.

    A fully instrumented subscale ground coupled heat pump system was developed, and built, and used to test and obtain data on three different earth heat exchanger configurations under heating conditions (ground cooling). Various refrigerant flow control and compressor protection devices were tested for their applicability to the direct expansion system. Undistributed Earth temperature data were acquired at various depths. The problem of oil return at low evaporator temperatures and low refrigerant velocities was addressed. An analysis was performed to theoretically determine what evaporator temperature can be expected with an isolated ground pipe configuration with given length, pipe size, soil conditions and constant heat load. Technical accomplishments to data are summarized.

  14. Thermal Stresses in an Anisotropic Thin Plate Subjected to Moving Plane Heat Sources

    Directory of Open Access Journals (Sweden)

    Malak Naji

    2014-04-01

    Full Text Available The aim of this study is to numerically simulate the plane moving heat source through anisotropic mild steal thin plate. Heat conduction problems in anisotropic material, where the thermal conductivity varies with direction and involving a moving heat source have several industrial applications, such like metal cutting, flame or laser hardening of metals, welding and others. The parabolic heat conduction model is used for the prediction of the temperature history. The temperature distribution inside the plate is determined from the solution of heat equation. Thus, the heat equation is solved numerically using finite deference method and the temperature distributions are determined. The thermal stresses in this case are, also, investigated and computed numerically. It is found that the thermal conductivity ratio affect in both temperature and thermal stresses distributions, in additional to the speed and heat source intensity.

  15. Thermodynamic formalism of minimum heat source temperature for driving advanced adsorption cooling device

    Science.gov (United States)

    Saha, Bidyut Baran; Chakraborty, Anutosh; Koyama, Shigeru; Srinivasan, Kandadai; Ng, Kim Choon; Kashiwagi, Takao; Dutta, Pradip

    2007-09-01

    This letter presents a thermodynamic formulation to calculate the minimum driving heat source temperature of an advanced solid sorption cooling device, and it is validated with experimental data. This formalism has been developed from the rigor of the Boltzmann distribution function and the condensation approximation of adsorptive molecules. An interesting and useful finding has been established from this formalism that it is possible to construct a solid sorption refrigeration device that operates in a cycle transferring heat from a low temperature source to a heat sink with a driving heat source at a temperature close to but above ambient.

  16. General expression of double ellipsoidal heat source model and its error analysis

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    In order to analyze the maximum power density error with different heat flux distribution parameter values for double ellipsoidal heat source model, a general expression of double ellipsoidal heat source model was derived from Goldak double ellipsoidal heat source model, and the error of maximum power density was analyzed under this foundation. The calculation error of thermal cycling parameters caused by the maximum power density error was compared quantitatively by numerical simulation. The results show that for guarantee the accuracy of welding numerical simulation, it is better to introduce an error correction coefficient into the Goldak double ellipsoidal heat source model expression. And, heat flux distribution parameter should get higher value for the higher power density welding methods.

  17. Thermoelectric Exhaust Heat Recovery with Heat Pipe-Based Thermal Control

    Science.gov (United States)

    Brito, F. P.; Martins, Jorge; Hançer, Esra; Antunes, Nuno; Gonçalves, L. M.

    2015-06-01

    Heat pipe (HP)-based heat exchangers can be used for very low resistance heat transfer between a hot and a cold source. Their operating temperature depends solely on the boiling point of their working fluid, so it is possible to control the heat transfer temperature if the pressure of the HP can be adjusted. This is the case of the variable conductance HPs (VCHP). This solution makes VCHPs ideal for the passive control of thermoelectric generator (TEG) temperature levels. The present work assesses, both theoretically and experimentally, the merit of the aforementioned approach. A thermal and electrical model of a TEG with VCHP assist is proposed. Experimental results obtained with a proof of concept prototype attached to a small single-cylinder engine are presented and used to validate the model. It was found that the HP heat exchanger indeed enables the TEG to operate at a constant, optimal temperature in a passive and safe way, and with a minimal overall thermal resistance, under part load, it effectively reduces the active module area without deprecating the temperature level of the active modules.

  18. Design and modelling of a novel compact power cycle for low temperature heat sources

    DEFF Research Database (Denmark)

    Wronski, Jorrit; Skovrup, Morten Juel; Elmegaard, Brian;

    2012-01-01

    Power cycles for the efficient use of low temperature heat sources experience increasing attention. This paper describes an alternative cycle design that offers potential advantages in terms of heat source exploitation. A concept for a reciprocating expander is presented that performs both, work...

  19. Recovery Act: Tennessee Energy Efficient Schools Initiative Ground Source Heat Pump Program

    Energy Technology Data Exchange (ETDEWEB)

    Townsend, Terry [Townsend Engineering, Inc., Davenport, IA (United States); Slusher, Scott [Townsend Engineering, Inc., Davenport, IA (United States)

    2017-04-24

    The Tennessee Energy Efficient Schools Initiative (EESI) Hybrid-Water Source Heat Pump (HY-GSHP) Program sought to provide installation costs and operation costs for different Hybrid water source heat pump systems’ configurations so that other State of Tennessee School Districts will have a resource for comparison purposes if considering a geothermal system.

  20. Temperature and Humidity Independent Control Research on Ground Source Heat Pump Air Conditioning System

    Science.gov (United States)

    Chen, G.; Wang, L. L.

    Taking green demonstration center building air conditioning system as an example, this paper presents the temperature and humidity independent control system combined with ground source heat pump system, emphasis on the design of dry terminal device system, fresh air system and ground source heat pump system.

  1. Thermal Management Controller for Heat Source Temperature Control and Thermal Management

    Institute of Scientific and Technical Information of China (English)

    HUANGFU Yi; WU Jing-yi; WANG Ru-zhu; LI Sheng

    2009-01-01

    In many heat recovery processes, temperature control of heat source is often required to ensure safety and high efficiency of the heat source equipment. In addition, the management of recovered heat is important for the proper use of waste heat. To this aim, the concept of thermal management controller (TMC), which can vary heat transfer rate via the volume variation of non-condensable gas, was presented. Theoretical model and experimental prototype were established. Investigation shows that the prototype is effective in temperature control. With water as the working fluid, the vapor temperature variation is only 1.3 ℃ when the heating power varies from 2.5 to 10.0 kW. In variable working conditions, this TMC can automatically adjust thermal allocation to the heat consumer.

  2. Thermal Stresses in an Anisotropic Thin Plate Subjected to Moving Line Heat Sources

    Directory of Open Access Journals (Sweden)

    Malak Naji

    2014-02-01

    Full Text Available The aim of this present study is to investigate thermal stresses inside a thin anisotropic mild steal plate during moving line heat source. The parabolic heat conduction model is used for the prediction of the temperature history. The temperature distributions are determined numerically using finite difference method. Thermal stresses are computed numerically. It is found that the thermal conductivity ratio affect in both temperature and thermal stresses distributions, in additional to the speed and heat source intensity.

  3. Beam heat load investigations with a cold vacuum chamber for diagnostics in a synchrotron light source

    Energy Technology Data Exchange (ETDEWEB)

    Voutta, Robert

    2016-04-22

    The beam heat load is a crucial input parameter for the cryogenic design of superconducting insertion devices. To understand the discrepancies between the predicted heat load of an electron beam to a cold bore and the heat load observed in superconducting devices, a cold vacuum chamber for diagnostics has been built. Extensive beam heat load measurements were performed at the Diamond light source. They are analysed systematically and combined with complementary impedance bench measurements.

  4. Beam heat load investigations with a cold vacuum chamber for diagnostics in a synchrotron light source

    OpenAIRE

    Voutta, Robert

    2016-01-01

    The beam heat load is a crucial input parameter for the cryogenic design of superconducting insertion devices. To understand the discrepancies between the predicted heat load of an electron beam to a cold bore and the heat load observed in superconducting devices, a cold vacuum chamber for diagnostics has been built. Extensive beam heat load measurements were performed at the Diamond light source. They are analysed systematically and combined with complementary impedance bench measurements.

  5. Development of dual-source hybrid heat pump system using groundwater and air

    Energy Technology Data Exchange (ETDEWEB)

    Nam, Yujin; Ooka, Ryozo [Cw403 Institute of Industry Science, The University of Tokyo, 4-6-1 Komaba, Meguro-ku, Tokyo 153-8505 (Japan); Shiba, Yoshiro [Zeneral Heatpump Industry Co., Ltd., Nagoya 459-8001 (Japan)

    2010-06-15

    To achieve high heat pump efficiency, groundwater heat pump (GWHP) system uses groundwater, which is relatively stable AT temperature compared with outdoor air, as a heat source. However, it is difficult to meet annual heating and cooling loads using only groundwater as a heat source. In order to optimize the operation method of GWHP systems, it is necessary to develop a system utilizing both groundwater and air sources according to the building load conditions. Furthermore, during intermediate seasons (such as spring and autumn) with reduced heating and cooling loads, GWHP system is less efficient than air source heat pump (ASHP) system according to temperature conditions. In order to more efficiently use GWHP systems, it is necessary to develop a system which utilizes both groundwater and air sources according to temperature conditions and building loads. This research has developed a GWHP system that employs a hybrid heat pump system with groundwater wells using dual groundwater and air heat sources. In this paper, the annual performance of the developed system has been calculated, and several case studies have been conducted on the effect of introduction location, refrigerant and pumping rate. Furthermore, the coefficient of system performance and the effects on underground environments have been evaluated by real-scale experiment using two wells. (author)

  6. Estimation of spatially varying heat transfer coefficient from a flat plate with flush mounted heat sources using Bayesian inference

    Science.gov (United States)

    Jakkareddy, Pradeep S.; Balaji, C.

    2016-09-01

    This paper employs the Bayesian based Metropolis Hasting - Markov Chain Monte Carlo algorithm to solve inverse heat transfer problem of determining the spatially varying heat transfer coefficient from a flat plate with flush mounted discrete heat sources with measured temperatures at the bottom of the plate. The Nusselt number is assumed to be of the form Nu = aReb(x/l)c . To input reasonable values of ’a’ and ‘b’ into the inverse problem, first limited two dimensional conjugate convection simulations were done with Comsol. Based on the guidance from this different values of ‘a’ and ‘b’ are input to a computationally less complex problem of conjugate conduction in the flat plate (15mm thickness) and temperature distributions at the bottom of the plate which is a more convenient location for measuring the temperatures without disturbing the flow were obtained. Since the goal of this work is to demonstrate the eficiacy of the Bayesian approach to accurately retrieve ‘a’ and ‘b’, numerically generated temperatures with known values of ‘a’ and ‘b’ are treated as ‘surrogate’ experimental data. The inverse problem is then solved by repeatedly using the forward solutions together with the MH-MCMC aprroach. To speed up the estimation, the forward model is replaced by an artificial neural network. The mean, maximum-a-posteriori and standard deviation of the estimated parameters ‘a’ and ‘b’ are reported. The robustness of the proposed method is examined, by synthetically adding noise to the temperatures.

  7. Air-Source Integrated Heat Pump System Development – Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Baxter, Van D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Rice, C. Keith [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Munk, Jeffrey D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Ally, Moonis R. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Shen, Bo [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Uselton, R. B. [Lennox Industries, Inc., Knoxville, TN (United States)

    2017-07-01

    Between October 2007 and September 2017, Oak Ridge National Laboratory (ORNL) and Lennox Industries, Inc. (Lennox) engaged in a Cooperative Research and Development Agreement (CRADA) to develop an air-source integrated heat pump (AS-IHP) system for the US residential market. The Lennox AS-IHP concept consisted of a high-efficiency air-source heat pump (ASHP) for space heating and cooling services and a separate heat pump water heater/dehumidifier (WH/DH) module for domestic water heating and dehumidification (DH) services. A key feature of this system approach with the separate WH/DH is capability to pretreat (i.e., dehumidify) ventilation air and dedicated whole-house DH independent of the ASHP. Two generations of laboratory prototype WH/DH units were designed, fabricated, and lab tested. Performance maps for the system were developed using the latest research version of the US Department of Energy/ORNL heat pump design model (Rice 1992; Rice and Jackson 2005; Shen et al. 2012) as calibrated against the lab test data. These maps served as the input to TRNSYS (Solar Energy Laboratory et al. 2010) to predict annual performance relative to a baseline suite of equipment meeting minimum efficiency standards in effect in 2006 (i.e., a combination of an ASHP with a seasonal energy efficiency ratio (SEER) of 13 and resistance water heater with an energy factor (EF) of 0.9). Predicted total annual energy savings (based on use of a two-speed ASHP and the second-generation WH/DH prototype for the AS-IHP), while providing space conditioning, water heating, and dehumidification for a tight, well-insulated 2600 ft2 (242 m2) house at three US locations, ranged from 33 to 36%, averaging 35%, relative to the baseline system. The lowest savings were seen at the cold-climate Chicago location. Predicted energy use for water heating was reduced by about 50 to 60% relative to a resistance WH.

  8. Heat Capacity Mapping Mission Digital Source: 1978-1980

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — NASA's Heat Capacity Mapping Mission (HCMM) project collected Earth data in the visible and thermal bands between April 1978 and September 1980. This was an...

  9. Heat Capacity Mapping Mission Digital Source: 1978-1980

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — NASA's Heat Capacity Mapping Mission (HCMM) project collected Earth data in the visible and thermal bands between April 1978 and September 1980. This was an...

  10. Annual investigation of vertical type ground source heat pump system performance on a wall heating and cooling system in Istanbul

    Energy Technology Data Exchange (ETDEWEB)

    Akbulut, U.; Yoru, Y.; Kincay, O. [Department of Mechanical Engineering, Yildiz Technical University (Turkey)], email: akbulutugur@yahoo.com, email: yilmazyoru@gmail.com, email: okincay@yildiz.edu.tr

    2011-07-01

    Wall heating and cooling systems (WHCS) are equipped with heating serpentines or panels for water circulation. These systems operate in a low temperature range so they are preferable to other, conventional systems. Furthermore, when these systems are connected to a ground source heat pump (GSHP) system, energy performance and thermal comfort are further enhanced. The purpose of this paper is to report the results of an annual inspection done on a vertical type ground-coupled heat pump systems (V-GSHP) WHCS in Istanbul and present the results. The performance data from the Yildiz Renewable Energy House at Davutpasa Campus of Yildiz Technical University, Istanbul, Turkey, during the year 2010 were collected and analyzed. The conclusions drawn from the inspection and analysis were listed in this paper. Using renewable energy sources effectively will bring both economic and environmental benefits and it is hoped that the use of these energy efficient WHCS systems will become widespread.

  11. Verification of Conjugate Heat Transfer Models in a Closed Volume with Radiative Heat Source

    Directory of Open Access Journals (Sweden)

    Maksimov Vyacheslav I.

    2016-01-01

    Full Text Available The results of verification of mathematical model of convective-conductive heat transfer in a closed volume with a thermally conductive enclosing structures are presented. Experiments were carried out to determine the temperature of floor premises in the working conditions of radiant heating systems. Comparison of mathematical modelling of temperature fields and experiments showed their good agreement. It is concluded that the mathematical model of conjugate heat transfers in the air cavity with a heat-conducting and heat-retaining walls correspond to the real process of formation of temperature fields in premises with gas infrared heaters system.

  12. Heat transfer in inclined air rectangular cavities with two localized heat sources

    Directory of Open Access Journals (Sweden)

    Samy M. Elsherbiny

    2015-12-01

    The investigation used rectangular enclosures with position ratios of the heaters, B1 = 0.25, B2 = 0.75, size ratio, ɛ = 0.25, and covered Rayleigh numbers based on scale length, s/A ranging from 103 to 106. The tilt angle from the horizontal was changed from Φ = 0° to 180°, and the aspect ratio was taken as A = 1, 5, and 10. The results are presented graphically in the form of streamlines and isotherm contour plots. The heat transfer characteristics, and average Nusselt numbers were also presented. A correlation for Nu is also given.

  13. Investment and Economy Analysis of Water-Source Heat Pump System in Chongqing, China

    Directory of Open Access Journals (Sweden)

    Yong Ding

    2013-01-01

    Full Text Available In China, the application of renewable energy witnesses rapid development. In the near future, a lot of demonstration projects will be built and thus it is urgent to know the economics of renewable energy building application technologies. Based on the renewable energy demonstration projects in Chongqing city, the author discussed the economy issue of water-source heat pump system (WSHPs in order to provide suggestions for the application projects. According to the design information of demonstration projects, the average incremental investment, allowance, and payback period are calculated in this paper. Comparing WSHPs with traditional heating, ventilation, and air conditioning (HVAC system, the saved energy of WSHPs is estimated in the current paper. The author calculated the amount of saved energy in unit applied area and unit intake water. Besides, the economy and efficiency of WSHPs project is analyzed at the end of this paper.

  14. Experiment Research on Freeze-thaw Splitting of Asphalt Concrete of Deicing and Snow Melting Based on Ground-Source Heat Pump%地源热泵融雪化冰沥青混凝土冻融劈裂实验研究

    Institute of Scientific and Technical Information of China (English)

    杨豪; 屠艳平; 朱志刚

    2016-01-01

    The technology of deicing and snow melting based on ground-source heat pump has many advantages, but some scholars pointed out that water damage was intensified because of deicing and snow melting. An experimental program was designed to estimate the degree of water damage of deicing and snow melting based on ground-source heat pump. The tensile splitting strength based on ground-source heat pump is 0.72MPa,but the tensile splitting strength of based on test procedures is 0.68MPa. The results showed that deicing and snow melting technology based on ground-source heat pump not only will increase the water damage of asphalt pavement, but also will improve the capability of resistance to water.%地源热泵融雪化冰技术具有许多优越性,有的学者指出道路融雪化冰会导致沥青路面水损害加剧。通过设计一套试验方案来评价利用地热源泵融雪化冰后路面的水损坏程度。地源热泵加热融化的试件的劈裂抗拉强度为0.72MPa,而根据试验规程测得的劈裂抗拉强度为0.68M孕a,结果表明地源热泵融雪化冰技术不仅不会增加沥青路面的水损害,还会提高路面抗水损害性能。

  15. Case study for ARRA-funded ground-source heat pump (GSHP) demonstration at Oakland University

    Energy Technology Data Exchange (ETDEWEB)

    Im, Piljae [ORNL; Liu, Xiaobing [ORNL

    2015-09-01

    High initial costs and lack of public awareness of ground-source heat pump (GSHP) technology are the two major barriers preventing rapid deployment of this energy-saving technology in the United States. Under the American Recovery and Reinvestment Act (ARRA), 26 GSHP projects have been competitively selected and carried out to demonstrate the benefits of GSHP systems and innovative technologies for cost reduction and/or performance improvement. This paper highlights the findings of a case study of one of the ARRA-funded GSHP demonstration projects, a ground-source variable refrigerant flow (GS-VRF) system installed at the Human Health Building at Oakland University in Rochester, Michigan. This case study is based on the analysis of measured performance data, maintenance records, construction costs, and simulations of the energy consumption of conventional central heating, ventilation, and air-conditioning (HVAC) systems providing the same level of space conditioning as the demonstrated GS-VRF system. The evaluated performance metrics include the energy efficiency of the heat pump equipment and the overall GS-VRF system, pumping performance, energy savings, carbon emission reductions, and cost-effectiveness of the GS-VRF system compared with conventional HVAC systems. This case study also identified opportunities for reducing uncertainties in the performance evaluation, improving the operational efficiency, and reducing the installed cost of similar GSHP systems in the future.

  16. Operation of a microwave plasma source for electron heating and antenna testing

    Science.gov (United States)

    Caughman, J. B. O.; Bigelow, T. S.; Diem, S. J.; Goulding, R. H.; Rasmussen, D. A.; Schaich, C. R.; White, T. L.

    2011-10-01

    One of the major challenges for magnetic fusion is the interaction of the plasma with materials. Linear plasma-material interaction test stands can benefit from additional electron heating of the high-density source plasma to increase the total plasma heat flux at the target to better simulate fusion reactor conditions (10-20 MW/m2). A microwave-based plasma experiment has begun at ORNL to study electron heating of over-dense plasmas and to provide a plasma environment for antenna testing. The plasma is generated by high-field launched whistler waves at 18 GHz to create a moderate-density plasma (ne ~1018/m3). Electron heating of the over-dense plasma is provided by either whistler waves or electron Bernstein waves at 6 GHz. In addition, a single strap mockup antenna, designed to operate at 40-50 MHz, is being constructed to study near-field plasma interactions. The antenna will be placed in the experiment's central vacuum chamber, which will act as an rf test facility. ORNL is managed by UT-Battelle, LLC, for the U.S. DOE under contract DE-AC-05-00OR22725.

  17. Thermoacoustic Instability in a Rijke Tube with a Distributed Heat Source

    Directory of Open Access Journals (Sweden)

    Xiaochuan Yang

    2015-01-01

    Full Text Available A Rijke tube with a distributed heat source is investigated. Driven by the widely existing thermoacoustic instability in lean premixed gas turbine combustors, this work aims to explore the physicochemical underpinning and assist in the elucidation and analysis of this problem. The heat release model consists of a row of distributed heat sources with individual heat release rates. The integrated heat release rate is then coupled with the acoustic perturbation for thermoacoustic analysis. A continuation approach is employed to conduct the bifurcation analysis and capture the nonlinear behaviour inherent in the system. Unlike the conventional approach by the Galerkin method, the acoustic equations are originally discretized using the Method of Lines (MOL to build up a dynamic system. The model is first validated and shown to yield good predictions with available experimental data. Influences of multiple heat sources, time delay, and heat release distribution are then studied to reveal the extensive nonlinear characteristics involved in the case of a distributed heat source. It is found that distributed heat source plays an important role in determining the stability of a thermoacoustic system.

  18. Case Study for the ARRA-Funded Ground Source Heat Pump Demonstration at Ball State University

    Energy Technology Data Exchange (ETDEWEB)

    Im, Piljae [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Liu, Xiaobing [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Henderson, Jr., Hugh [CDH Energy Corp., Beijing (China)

    2016-12-01

    With funding provided by the American Recovery and Reinvestment Act (ARRA), 26 ground-source heat pump (GSHP) projects were competitively selected in 2009 to demonstrate the benefits of GSHP systems and innovative technologies for cost reduction and/or performance improvement. One of the selected demonstration projects is a district central GSHP system installed at Ball State University (BSU) in Muncie, IN. Prior to implementing the district GSHP system, 47 major buildings in BSU were served by a central steam plant with four coal-fired and three natural-gas-fired steam boilers. Cooling was provided by five water-cooled centrifugal chillers at the District Energy Station South (DESS). The new district GSHP system replaced the existing coal-fired steam boilers and conventional water-cooled chillers. It uses ground-coupled heat recovery (HR) chillers to meet the simultaneous heating and cooling demands of the campus. The actual performance of the GSHP system was analyzed based on available measured data from August 2015 through July 2016, construction drawings, maintenance records, personal communications, and construction costs. Since Phase 1 was funded in part by the ARRA grant, it is the focus of this case study. The annual energy consumption of the GSHP system was calculated based on the available measured data and other related information. It was compared with the performance of a baseline scenario— a conventional water-cooled chiller and natural-gas-fired boiler system, both of which meet the minimum energy efficiencies allowed by the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE 90.1-2013). The comparison was made to determine source energy savings, energy cost savings, and CO2 emission reductions achieved by the GSHP system. A cost analysis was performed to evaluate the simple payback of the GSHP system. The following sections summarize the results of the analysis, the lessons learned, and recommendations for improvement

  19. Identification of radiogenic heat source distribution in the crust: A variational approach

    Indian Academy of Sciences (India)

    R N Singh; Ajay Manglik

    2000-04-01

    Radiogenic heat sources present in the continental crust contribute significantly to the total surface heat flow and temperature distribution in the crust. Various modelsforthe depth distribution of radiogenic sources have been proposed. Among these modelsthe exponential model has been shown to be an optimal, smooth model through the variational approach applied to the heat conduction equation. In the present work, a two-layered model of the crust is considered and heat transport by advection is included in the upper layer. The heat transport in the lower layer is by conduction only. Application of variational principle determines the nature of the radiogenic source distribution in both the layers. The resultsthus obtained indicate a radiogenic source distribution which is more complex than a simple exponential model.

  20. Quantifying Systemic Efficiency using Exergy and Energy Analysis for Ground Source Heat Pumps: Domestic Space Conditioning and Water Heating Applications.

    Energy Technology Data Exchange (ETDEWEB)

    Ally, Moonis Raza [ORNL; Baxter, Van D [ORNL; Gehl, Anthony C [ORNL; Munk, Jeffrey D [ORNL

    2017-01-01

    Although air temperatures over land surfaces show wide seasonal and daily variations, the ground, approximately 10 meters below the earth s surface, remains relatively stable in temperature thereby serving as an energy source or sink. Ground source heat pumps can heat, cool, and supply homes with hot water efficiently by utilizing the earth s renewable and essentially inexhaustible energy resources, saving fossil fuels, reducing greenhouse gas emissions, and lowering the environmental footprint. In this paper, evidence is shown that ground source heat pumps can provide up to 79%-87% of domestic hot water energy needs, and up to 77% of space heating needs with the ground s thermal energy resources. The case refers to a 12-month study conducted at a 253 m2 research house located in Oak Ridge, Tennessee, 36.01 N 84.26 W in a mixed-humid climate with HDD of 2218 C-days and CDD of 723 C-days under simulated occupancy conditions. A single 94.5m vertical bore interfaced the heat pump with the ground. The research shows that this technology is capable of achieving US DOE targets of 25 % and 35% energy savings in HVAC, and in water heating, respectively by 2030. It is also a viable technology to meet greenhouse gas target emissions under the IECC 2012 Standard, as well as the European Union (EU) 2020 targets of using renewable energy resources. The paper quantifies systemic efficiencies using Exergy analysis of the major components, clearly pointing areas for further improvement.

  1. Transition to chaos in a square enclosure containing internal heat sources

    Energy Technology Data Exchange (ETDEWEB)

    Baytas, A.C. [Institute For Nuclear Energy, Istanbul (Turkey)

    1995-09-01

    A numerical investigation is performed to study the transition from steady to chaotic flow of a fluid confined in a two-dimensional square cavity. The cavity has rigid walls of constant temperature containing uniformly distributed internal heat source. Effects of the Rayleigh number of flow and heat transfer rates are studied. In addition to, same problem is solved for sinusoidally changing internal heat source to show its effect on the flow model and heat transfer of the enclosures. Details of oscillatory solutions and flow bifurcations are presented.

  2. Comparison between off-resonance and electron Bernstein waves heating regime in a microwave discharge ion source

    Energy Technology Data Exchange (ETDEWEB)

    Castro, G.; Di Giugno, R.; Miracoli, R. [INFN- Laboratori Nazionali del Sud, via S. Sofia 62, 95123 Catania (Italy); Universita degli Studi di Catania, Dipartimento di Fisica e Astronomia, V. S. Sofia 64, 95123 Catania (Italy); Mascali, D. [INFN- Laboratori Nazionali del Sud, via S. Sofia 62, 95123 Catania (Italy); CSFNSM, Viale A. Doria 6, 95125 Catania (Italy); Romano, F. P. [INFN- Laboratori Nazionali del Sud, via S. Sofia 62, 95123 Catania (Italy); CNR-IBAM Via Biblioteca 4, 95124 Catania (Italy); Celona, L.; Gammino, S.; Lanaia, D.; Ciavola, G. [INFN- Laboratori Nazionali del Sud, via S. Sofia 62, 95123 Catania (Italy); Serafino, T. [CSFNSM, Viale A. Doria 6, 95125 Catania (Italy); Di Bartolo, F. [Universita di Messina, Ctr. da Papardo-Sperone, 98100 Messina (Italy); Gambino, N. [INFN- Laboratori Nazionali del Sud, via S. Sofia 62, 95123 Catania (Italy); Universita degli Studi di Catania, Dipartimento di Fisica e Astronomia, V. S. Sofia 64, 95123 Catania (Italy); IET-Institute of Energy Technology, LEC-Laboratory for Energy Conversion, ETH Zurich, Sonneggstrasse 3, CH-8092 Zurich (Switzerland)

    2012-02-15

    A microwave discharge ion source (MDIS) operating at the Laboratori Nazionali del Sud of INFN, Catania has been used to compare the traditional electron cyclotron resonance (ECR) heating with an innovative mechanisms of plasma ignition based on the electrostatic Bernstein waves (EBW). EBW are obtained via the inner plasma electromagnetic-to-electrostatic wave conversion and they are absorbed by the plasma at cyclotron resonance harmonics. The heating of plasma by means of EBW at particular frequencies enabled us to reach densities much larger than the cutoff ones. Evidences of EBW generation and absorption together with X-ray emissions due to high energy electrons will be shown. A characterization of the discharge heating process in MDISs as a generalization of the ECR heating mechanism by means of ray tracing will be shown in order to highlight the fundamental physical differences between ECR and EBW heating.

  3. Numerical simulation of seepage flow field in groundwater source heat pump system and its influence on temperature field

    Institute of Scientific and Technical Information of China (English)

    Jihua HU; Yanjun ZHANG; Danyan DU; Gang WU; Ziwang YU; Chen WANG; Fuquan NI

    2008-01-01

    Energy utilization in the aquifers is a new technology closely related to development of heat pump technique. It is significant for the flow distribution to be predicted in the aquifer surrounding the Groundwater Source Heat Pump System (GSHPS). The authors presented a new concept of "flow transfixion" by analyzing general features of aquifers, and then discussed interaction of the flow transfixion with the heat transfixion, which has practical significance to projects. A numerical model of groundwater flow was established based on the basic tenets of water-heat transferring in the aquifer. On this basis the flow field and the temperature field of GSHPS for a site in Shenyang City were numerically simulated. The basis of the flow transfixion was obtained; it was discussed for the influence of the flow transfixion on the heat transfixion. To a certain extent, the study offers some reference for the projects' design of GSHP in the studied area.

  4. Maximum work for Carnot-like heat engines with infinite heat source

    CERN Document Server

    Long, Rui

    2014-01-01

    An analysis of efficiency and its bounds at maximum work output for Carnot-like heat engines is conducted. The heat transfer processes are described by the linear law with time-dependent heat conductance. The upper bound of efficiency is found to be the CA efficiency,and is independent of the time duration completing each process and the time-dependent conductance. We prove that even the working medium exchanges heat sufficiently with the heat reservoirs, the work which could be extracted is finite and limited. The optimal temperature profiles in the heat exchanging processes are also analyzed. When the dimensionless contact times satisfy certain relations,the endoreversible model is recovered.

  5. Field Investigation of an Air-Source Cold Climate Heat Pump

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Bo [ORNL; Abdelaziz, Omar [ORNL; Rice, C Keith [ORNL; Baxter, Van D [ORNL

    2017-01-01

    In the U.S., there are approximately 2.6 million dwellings that use electricity for heating in cold and very cold regions with an annual energy consumption of 0.16 quads (0.17 EJ). A high performance cold climate heat pump (CCHP) would result in significant savings over current technologies (greater than 60% compared to electric resistance heating). We developed an air-source cold climate heat pump, which uses tandem compressors, with a single compressor rated for the building design cooling load, and running two compressors to provide, at -13 F (-25 C), 75% of rated heating capacity. The tandem compressors were optimized for heating operation and are able to tolerate discharge temperatures up to 280 F (138 C). A field investigation was conducted in the winter of 2015, in an occupied home in Ohio, USA. During the heating season, the seasonal COP was measured at 3.16, and the heat pump was able to operate down to -13 F (-25 C) and eliminate resistance heat use. The heat pump maintained an acceptable comfort level throughout the heating season. In comparison to a previous single-speed heat pump in the home, the CCHP demonstrated more than 40% energy savings in the peak heating load month. This paper illustrates the measured field performance, including compressor run time, frost/defrosting operations, distributions of building heating load and capacity delivery, comfort level, field measured COPs, etc.

  6. 基于多源遥感数据的北京城市热岛研究%Research on Urban Heat Island in Beijing Based on Multi-source Remote Sensing Data

    Institute of Scientific and Technical Information of China (English)

    彭仲

    2009-01-01

    The atmosphere parameter-atmosphere water vapor content that needed in retrieval of land surface temperature was firstly calculated on pixel scale with MODIS data. The land surface temperature was retried with Landsat TM image by generalized single-channel method of Jimenez-Munoz and Sobrino. The inversion result was detected according to the measured data of land surface temperature. The results showed that the accuracy of the inversion result on land surface temperature with multi-source remote sensing data was higher. The urban heat island status in Beijing was studied by this method. It was found that the urban heat island effect in Beijing was obvious, and the low fractional vegetation cover in urban areas was one of the main reasons of urban heat island appearing.%首先利用MODIS数据在像元尺度上获取地表温度反演中所需大气参数-大气水分含量,再利用Landsat TM影像采用Jimenez-Munoz和Sobrino的普适性单通道算法反演地表温度,通过地面实测数据对反演结果进行验证.结果表明,利用多源遥感数据反演地表温度具有较高的精度.用该方法对北京城市热岛状况进行研究,发现北京城市热岛效应十分明显,地表植被覆盖度低是城市热岛出现的主要原因之一.

  7. Novel designs for undulator based positron sources

    OpenAIRE

    Jenkins, Mike; Bailey, Ian

    2015-01-01

    Proposed high energy electron-positron linear colliders require a high ux of positrons. To achieve this a number of new positron source designs have been proposed. One of these is an undulator-based positron source, which is the baseline positron source design for the International Linear Collider. The undulator-based positron source for the International Linear Collider uses a helical undulator to produce a intense photon beam that generates positrons through the pairproduction mechanism. As...

  8. Federal Technology Alert: Ground-Source Heat Pumps Applied to Federal Facilities--Second Edition

    Energy Technology Data Exchange (ETDEWEB)

    Hadley, Donald L.

    2001-03-01

    This Federal Technology Alert, which was sponsored by the U.S. Department of Energy's Office of Federal Energy Management Programs, provides the detailed information and procedures that a Federal energy manager needs to evaluate most ground-source heat pump applications. This report updates an earlier report on ground-source heat pumps that was published in September 1995. In the current report, general benefits of this technology to the Federal sector are described, as are ground-source heat pump operation, system types, design variations, energy savings, and other benefits. In addition, information on current manufacturers, technology users, and references for further reading are provided.

  9. The Suitability Zoning Division for Groundwater Source Heat Pump Based on Analytic Hierarchy Process in Qinhuangdao%基于层次分析法的秦皇岛地下水源热泵适宜性区划

    Institute of Scientific and Technical Information of China (English)

    回广荣

    2015-01-01

    The shallow geothermal energy is a new type of clean energy. The paper makes suitability zoning for groundwa-ter source heat pump in Qinhuangdao by Analytic Hierarchy Process, to provide the basis for exploitation and utilization plan-ning of shallow geothermal energy. It introduces the steps and methods of determining the weights by AHP, and establishes the evaluation index system about suitability zoning of groundwater source heat pump. At last, the comprehensive evaluation index method is used to evaluate the suitability. The evaluation results indicate that the less suitable area 114. 67 km2,accounting for 19% of the study area, and the unsuitable area 304. 09 km2,accounted for 50. 4%.%浅层地温能是一种新型清洁能源,采用层次分析法在秦皇岛进行地下水地源热泵适宜性区划,为浅层地温能开发利用规划提供依据. 讨论层次分析法确定权重的步骤和方法,针对地下水地源热泵适宜性区划指标体系的建立和指标量化,利用综合评价指数法将本区分为地下水地源热泵较适宜区和不适宜区. 较适宜区面积114. 67 km2,占研究区19%,不适宜区分布面积304. 09 km2,占研究区50. 4%.

  10. Link between intermittent electrical energy sources and district heating sector

    DEFF Research Database (Denmark)

    Dominkovic, Dominik Franjo

    2016-01-01

    Energy has always been one of the key challenges in planning of societies' development worldwide. The COP conference in Paris in December 2015 has shown unprecedented mutual understanding of harmful consequences climate change can cause. Integrating power and heating sectors in an efficient way...

  11. Link between intermittent electrical energy sources and district heating sector

    DEFF Research Database (Denmark)

    Dominkovic, Dominik Franjo

    2016-01-01

    Energy has always been one of the key challenges in planning of societies' development worldwide. The COP conference in Paris in December 2015 has shown unprecedented mutual understanding of harmful consequences climate change can cause. Integrating power and heating sectors in an efficient way...

  12. Heat exchanger design based on economic optimisation

    Energy Technology Data Exchange (ETDEWEB)

    Caputo, Antonio C.; Pelagagge, Pacifico M.; Salini, Paolo [University of L' Aquila, Engineering Faculty, Monteluco di Roio 67100, L' Aquila (Italy)

    2008-07-15

    Owing to the wide utilization of heat exchangers in industrial processes, their cost minimization is an important target for both designers and users. Traditional design approaches are based on iterative procedures which gradually change design parameters until a satisfying solution, which meets the design specifications, is reached. However, such methods, besides being time consuming, do not guarantee the reach of an economically optimal solution. In this paper a procedure for optimal design of shell and tube heat exchangers is proposed, which utilizes a genetic algorithm to minimize the total cost of the equipment including capital investment and the sum of discounted annual energy expenditures related to pumping. In order to verify the capability of the proposed method, three case studies are also presented showing that significant cost reductions are feasible with respect to traditionally designed exchangers. In particular, in the examined cases a reduction of total costs up to more than 50% was observed. (author)

  13. Heat exchanger design based on economic optimization

    Energy Technology Data Exchange (ETDEWEB)

    Caputo, Antonio C.; Pelagagge, Marcello P.; Salini, Paolo [University of l' Aquila (Italy). Faculty of Engineering], e-mail: caputo@ing.inivaq.it, e-mail: pelmar@ing.inivaq.it, e-mail: salini@ing.inivaq.it

    2006-07-01

    Owing to the wide utilization of heat exchangers in industrial processes their cost minimization is an important target for both designers and users. Traditional design approaches are based on iterative procedures which assume a configuration and gradually change design parameters until a satisfying solution is reached which meets the design specifications. However, such methods, besides being time consuming, do not guarantee the reach of an optimal solution. In this paper a procedure for optimal design for shell and tube heat exchangers is proposed which utilizes a genetic algorithm to minimize the total discounted cost of the equipment including the capital investment and pumping related annual energy expenditures. In order to verify the performances of the proposed method four case studies are also presented showing that total cost reductions greater than 15% are feasible respect traditionally designed exchangers. (author)

  14. Research on Combined Application Technology of Solar and Ground Source Heat Pump in Severe Cold Area based on TRNSYS%基于TRNSYS的严寒地区太阳能和地源热泵联合应用技术研究

    Institute of Scientific and Technical Information of China (English)

    潘建伍

    2013-01-01

    Based on TRNSYS software numerical simulation, research on the technical feasibility and the parameter optimization of combined application technology of solar energy and ground source heat pump in severe cold area were carried out. The results showed combined application technology of solar energy and ground source heat pump in severe cold area is feasible. Parallel source-side complement heating mode has relatively high efficiency, so flat plate collector was recommended. COP of the source side thermal complement parallel system increases non-linearly with the collector area, but it stabilizes when reaching a certain value.%基于对TRNSYS软件进行数值模拟,在严寒地区对太阳能和地源热泵联合应用技术的可行性和参数优选等问题进行研究.结果表明,在严寒地区采用太阳能和地源热泵联合供热采暖系统是可行的,采用并联型源侧补热模式的效率相对较高,建议选用平板式集热器,并联型源侧补热系统的全年COP随集热器面积的增大,非线性提高到一定值之后,COP趋于稳定.

  15. Economic Model Predictive Control for Hot Water Based Heating Systems in Smart Buildings

    DEFF Research Database (Denmark)

    Awadelrahman, M. A. Ahmed; Zong, Yi; Li, Hongwei

    2017-01-01

    This paper presents a study to optimize the heating energy costs in a residential building with varying electricity price signals based on an Economic Model Predictive Controller (EMPC). The investigated heating system consists of an air source heat pump (ASHP) incorporated with a hot water tank...... as active Thermal Energy Storage (TES), where two optimization problems are integrated together to optimize both the ASHP electricity consumption and the building heating consumption utilizing a heat dynamic model of the building. The results show that the proposed EMPC can save the energy cost by load...

  16. Geothermal heat potential - the source for heating greenhouses in Southestern Europe

    Directory of Open Access Journals (Sweden)

    Urbancl Danijela

    2016-01-01

    Full Text Available The paper presents economically evaluated solutions for heating greenhouses with geothermal potential, if the same greenhouse is placed in two different locations in Southeastern Europe, one in Slovenia and the other in Serbia. The direct geothermal water exploitation using heat exchangers is presented and the remaining heat potential of already used geothermal water is exploited using high temperature heat pumps. Energy demands for heating greenhouses are calculated considering climatic parameters of both locations. Furthermore, different constructions materials are taken into account, and energy demands are evaluated if the same greenhouse is made of 4 mm toughened single glass, double insulated glass or polycarbonate plates. The results show that the geothermal energy usage is economically feasible in both locations, because payback periods are in range from two to almost eight years for different scenarios.

  17. Efficiency of Vertical Geothermal Heat Exchangers in the Ground Source Heat Pump System

    Institute of Scientific and Technical Information of China (English)

    Heyi Zeng; Nairen Diao; Zhaohong Fang

    2003-01-01

    Taking the fluid temperature distribution along the borehole depth into account, a new quasi-three-dimensional model for vertical ground heat exchangers has been established, which provides a better understanding of the heat transfer processes in the geothermal heat exchangers. On this basis the efficiency of the borehole has been defined and its analytical expression derived. Comparison with the previous two-dimensional model shows that the quasi-three-dimensional model is more rational and more accurate to depict the practical feature of the conduction of geothermal heat exchanger, and the efficiency notion can be easily used to determine the inlet and outlet temperature of the circulating fluid inside the heat exchanger.

  18. Multi-Bed Multi-Stage Adsorption Refrigeration Cycle-Reducing Driving Heat Source Temperature

    Science.gov (United States)

    Alam, K. C. Amanul; Akahira, Akira; Hamamoto, Yoshinori; Akisawa, Atsushi; Kashiwagi, Takao; Saha, Bidyut Baran; Koyama, Shigeru; Ng, Kim Choon; Chua, Hui Tong

    The study aims at designing a multi-bed multi-stage adsorption chiller that can be driven by waste heat at near ambient temperature. The chiller is designed such a way that it can be switched into different modes depending on the driving heat source temperature. Stage regeneration techniques have been applied to operate the chiller by relatively low temperature heat source. Driving heat source temperature is validated by simulated data and the performances obtained from different modes are compared. In terms of COP (Coefficient of performance),the chiller shows best performance in conventional single-stage mode for driving heat source temperature greater than 60°C, two stage mode for driving source temperature between 42 and 60°C,in three-stage mode for driving source temperature less than 42°C. In terms of cooling capacity, it shows the best performance in single-stage mode for heat source temperature greater than 70°C. The mass recovery process in single-stage mode is also examined. It is seen that the mass recovery process improve cooling capacity significantly, specially for the low regenerating temperature region.

  19. Buoyancy-Driven Radiative Unsteady Magnetohydrodynamic Heat Transfer over a Stretching Sheet with non-Uniform Heat Source/sink

    Directory of Open Access Journals (Sweden)

    Dulal Pal

    2016-01-01

    Full Text Available In the present study an unsteady mixed convection boundary layer flow of an electrically conduct- ing fluid over an stretching permeable sheet in the presence of transverse magnetic field, thermal radiation and non-uniform heat source/sink effects is investigated. The unsteadiness in the flow and temperature fields is due to the time-dependent nature of the stretching velocity and the surface temperature. Both opposing and assisting flows are considered. The dimensionless governing or- dinary non-linear differential equations are solved numerically by applying shooting method using Runge-Kutta-Fehlberg method. The effects of unsteadiness parameter, buoyancy parameter, thermal radiation, Eckert number, Prandtl number and non-uniform heat source/sink parameter on the flow and heat transfer characteristics are thoroughly examined. Comparisons of the present results with previously published results for the steady case are found to be excellent.

  20. Nanofluid Flow past an Unsteady Permeable Shrinking Sheet with Heat Source or Sink and Newtonian Heating in a Porous Medium

    Directory of Open Access Journals (Sweden)

    M.Lavanya

    2016-02-01

    Full Text Available The consideration of nanofluids has been paid a good attention on the forced convection; the analysis focusing nanofluids in porous media are limited in literature. Thus, the use of nanofluids in porous media would be very much helpful in heat and mass transfer enhancement. In this paper, the influence of variable suction, Newtonian heating and heat source or sink heat and mass transfer over a permeable shrinking sheet embedded in a porous medium filled with a nanofluid is discussed in detail. The solutions of the nonlinear equations governing the velocɨty, temperature and concentration profiles are solved numerically using Runge-Kutta Gill procedure together with shooting method and graphical results for the resulting parameters are displayed and discussed. The influence of the physical parameters on skin-friction coefficient, local Nusselt number and local Sherwood number are shown in a tabulated form.

  1. Thermal non-equilibrium heat transfer in a porous cavity in the presence of bio-chemical heat source

    Directory of Open Access Journals (Sweden)

    Nazari Mohsen

    2015-01-01

    Full Text Available This paper is concerned with thermal non-equilibrium natural convection in a square cavity filled with a porous medium in the presence of a biomass which is transported in the cavity. The biomass can consume a secondary moving substrate. The physics of the presented problem is related to the analysis of heat and mass transfer in a composting process that controlled by internal heat generation. The intensity of the bio-heat source generated in the cavity is equal to the rate of consumption of the substrate by the biomass. It is assumed that the porous medium is homogeneous and isotropic. A two-field model that represents the fluid and solid phase temperature fields separately is used for energy equation. A simplified Monod model is introduced along with the governing equations to describe the consumption of the substrate by the biomass. In other word, the transient biochemical heat source which is dependent on a solute concentration is considered in the energy equations. Investigation of the biomass activity and bio-chemical heat generation in the case of thermal non-equilibrium assumption has not been considered in the literature and they are open research topics. The effects of thermal non-equilibrium model on heat transfer, flow pattern and biomass transfer are investigated. The effective parameters which have a direct impact on the generated bio-chemical heat source are also presented. The influences of the non-dimensional parameters such as fluid-to-solid conductivity ratio on the temperature distribution are presented.

  2. Heat expanded starch-based compositions.

    Science.gov (United States)

    Glenn, Gregory M; Klamczynski, Artur K; Holtman, Kevin M; Shey, Justin; Chiou, Bor-Sen; Berrios, Jose; Wood, Delilah; Orts, William J; Imam, Syed H

    2007-05-16

    A heat expansion process similar to that used for expanded bead polystyrene was used to expand starch-based compositions. Foam beads made by solvent extraction had the appearance of polystyrene beads but did not expand when heated due to an open-cell structure. Nonporous beads, pellets, or particles were made by extrusion or by drying and milling cooked starch slurries. The samples expanded into a low-density foam by heating 190-210 degrees C for more than 20 s at ambient pressures. Formulations containing starch (50-85%), sorbitol (5-15%), glycerol (4-12%), ethylene vinyl alcohol (EVAL, 5-15%), and water (10-20%) were studied. The bulk density was negatively correlated to sorbitol, glycerol, and water content. Increasing the EVAL content increased the bulk density, especially at concentrations higher than 15%. Poly(vinyl alcohol) (PVAL) increased the bulk density more than EVAL. The bulk density was lowest in samples made of wheat and potato starch as compared to corn starch. The expansion temperature for the starch pellets decreased more than 20 degrees C as the moisture content was increased from 10 to 25%. The addition of EVAL in the formulations decreased the equilibrium moisture content of the foam and reduced the water absorption during a 1 h soaking period.

  3. ENERGY STAR Certified Non-AHRI Central Air Conditioner Equipment and Air Source Heat Pump

    Data.gov (United States)

    U.S. Environmental Protection Agency — Certified models meet all ENERGY STAR requirements as listed in the Version 5.0 ENERGY STAR Program Requirements for Air Source Heat Pump and Central Air Conditioner...

  4. Energy well. Ground-source heat in one-family houses; Energiakaivo. Maalaemmoen hyoedyntaeminen pientaloissa

    Energy Technology Data Exchange (ETDEWEB)

    Juvonen, J.; Lapinlampi, T.

    2013-08-15

    This guide deals with the legislation, planning, building, usage and maintenance of ground-source heat systems. The guide gives recommendations and instructions on national level on the permit practices and how to carry out the whole ground-source heat system project. The main focus of the guide is on energy wells for one-family houses. The principle is that an action permit is needed to build a ground-source heat system. On ground water areas a permit according to the water act may also be required. To avoid any problems, the placement of the system needs to be planned precisely. This guide gives a comprehension to the orderer on the issues that need to be considered before ordering, during construction, when the system is running and when giving up the use of the ground-source heat system. (orig.)

  5. Characterization of the Inductively Heated Plasma Source IPG6-B

    Science.gov (United States)

    Dropmann, Michael; Laufer, Rene; Herdrich, Georg; Matthews, Lorin; Hyde, Truell

    2014-10-01

    In close collaboration between the Center for Astrophysics, Space Physics and Engineering Research (CASPER) at Baylor University, Texas, and the Institute of Space Systems (IRS) at the University of Stuttgart, Germany, two plasma facilities have been established using the Inductively heated Plasma Generator 6 (IPG6). The facility at Baylor University (IPG6-B) works at a frequency of 13.56 MHz and a maximum power of 15 kW. A vacuum pump of 160 m3/h in combination with a butterfly valve allows pressure control over a wide range. Intended fields of research include basic investigation into thermo-chemistry and plasma radiation, space plasma environments and high heat fluxes e.g. those found in fusion devices or during atmospheric re-entry of spacecraft. After moving the IPG6-B facility to the Baylor Research and Innovation Collaborative (BRIC) it was placed back into operation during the summer of 2014. Initial characterization in the new lab, using a heat flux probe, Pitot probe and cavity calorimeter, has been conducted for Air, Argon and Helium. The results of this characterization are presented.

  6. Magnetic pumping as a source of particle heating

    Science.gov (United States)

    Lichko, Emily; Egedal, Jan; Daughton, William; Kasper, Justin

    2016-10-01

    Magnetic pumping is a means of heating plasmas for both fusion and astrophysical applications. This study presents a generalized model, related to the compressional pumping model Fisk & Gloeckler applied to the solar wind (2006). Unlike previous models, this model includes diffusion of the anisotropic features which develop in velocity space, thereby allowing energy to be transferred to the particles directly from the turbulence. By using various orderings, the drift kinetic equation can be reduced to a more general form of Parker's equation with an anisotropic distribution function. Through expansions in both pitch angle and in space, it can be shown that this equation has power law solutions and results in an overall heating of the plasma. This form of heating is related to transit-time damping. Kinetic simulations were performed to test the theoretical model and explore regimes where spatial and velocity diffusion are of the same order of importance, regimes not easily available to analytical calculations. These simulations appear to confirm the pumping model in the appropriate limits.

  7. National Certification Standard for Ground Source Heat Pump Personnel

    Energy Technology Data Exchange (ETDEWEB)

    Kelly, John [Geothermal Heat Pump Consortium, Washington, DC (United States)

    2013-07-31

    The National Certification Standard for the Geothermal Heat Pump Industry adds to the understanding of the barriers to rapid growth of the geothermal heat pump (GHP) industry by bringing together for the first time an analysis of the roles and responsibilities of each of the individual job tasks involved in the design and installation of GHP systems. The standard addresses applicable qualifications for all primary personnel involved in the design, installation, commissioning, operation and maintenance of GHP systems, including their knowledge, skills and abilities. The resulting standard serves as a foundation for subsequent development of curriculum, training and certification programs, which are not included in the scope of this project, but are briefly addressed in the standard to describe ways in which the standard developed in this project may form a foundation to support further progress in accomplishing those other efforts. Follow-on efforts may use the standard developed in this project to improve the technical effectiveness and economic feasibility of curriculum development and training programs for GHP industry personnel, by providing a more complete and objective assessment of the individual job tasks necessary for successful implementation of GHP systems. When incorporated into future certification programs for GHP personnel, the standard will facilitate increased consumer confidence in GHP technology, reduce the potential for improperly installed GHP systems, and assure GHP system quality and performance, all of which benefit the public through improved energy efficiency and mitigated environmental impacts of the heating and cooling of homes and businesses.

  8. Performance of water source heat pump system using high-density polyethylene tube heat exchanger wound with square copper wire

    Directory of Open Access Journals (Sweden)

    Xin Wen Zhang

    2015-07-01

    Full Text Available Surface water source heat pump system is an energy-efficient heat pump system. Surface water heat exchanger is an important part of heat pump system that can affect the performance of the system. In order to enhance the performance of the system, the overall heat transfer coefficient (U value of the water exchanger using a 32A square copper coiled high-density polyethylene tube was researched. Comparative experiments were conducted between the performance of the coiled high-density polyethylene tube and the 32A smooth high-density polyethylene tube. At the same time, the coefficient of performance of the heat pump was investigated. According to the result, the U value of the coiled tube was 18% higher than that of the smooth tube in natural convection and 19% higher in forced convection. The coefficient of performance of the heat pump with the coiled tube is higher than that with the smooth tube. The economic evaluation of the coiled tube was also investigated.

  9. On the addition of heat to solar pond from external sources

    NARCIS (Netherlands)

    Ganguly, S.; Jain, Ravi; Date, Abhijit; Akbarzadeh, Aliakbar

    2017-01-01

    This brief note addresses the method of adding heat to a solar pond from an external source which is used to enhance the performance of a solar pond. Heat energy collected by Evacuated Tube Solar Collectors (ETSC) is transferred by circulating fluid from the Lower Convective Zone (LCZ) of a solar po

  10. A flexible and low cost experimental stand for air source heat pump for Smart Buildings

    DEFF Research Database (Denmark)

    Crăciun, Vasile S.; Bojesen, Carsten; Blarke, Morten

    2012-01-01

    prices. A significant part of this challenge may be dealt with in the way space heating, space cooling, and domestic hot water production which is provided to residential and commercial buildings. Air source heat pumps (ASHP) are widely used conversion technologies for providing building thermal energy...

  11. On the addition of heat to solar pond from external sources

    NARCIS (Netherlands)

    Ganguly, S.; Jain, Ravi; Date, Abhijit; Akbarzadeh, Aliakbar

    2017-01-01

    This brief note addresses the method of adding heat to a solar pond from an external source which is used to enhance the performance of a solar pond. Heat energy collected by Evacuated Tube Solar Collectors (ETSC) is transferred by circulating fluid from the Lower Convective Zone (LCZ) of a solar

  12. Technology Solutions Case Study: Ground Source Heat Pump Research, TaC Studios Residence, Atlanta, Georigia

    Energy Technology Data Exchange (ETDEWEB)

    None

    2014-09-01

    This case study describes the construction of a new test home that demonstrates current best practices for the mixed-humid climate, including a high performance ground source heat pump for heating and cooling, a building envelope featuring advanced air sealing details and low-density spray foam insulation, and glazing that exceeds ENERGY STAR requirements.

  13. Using Ground Source Heat Pumps for Renewable Energy

    OpenAIRE

    Xhevat BERISHA

    2017-01-01

    This paper provides background information on the current energy supply, energy demand, and energy sources in Kosovo. Moreover, it presents the country‟s current level of applying alternative energy sources. Additionally, this paper focuses on geothermal energy as a renewable energy resource with the potential to contribute to a sustainable use of resources to meet renewable energy and energy efficiency requirements of the European Union (EU), “EU 20 20 by 2020” policy. Hence, a careful analy...

  14. An Electrothermal Plasma Source Developed for Simulation of Transient Heat Loads in Future Large Fusion Devices

    Science.gov (United States)

    Gebhart, Trey; Baylor, Larry; Winfrey, Leigh

    2016-10-01

    The realization of fusion energy requires materials that can withstand high heat and particle fluxes at the plasma material interface. In this work, an electrothermal (ET) plasma source has been designed as a possible transient heat flux source for a linear plasma material interaction device. An ET plasma source operates in the ablative arc regime, which is driven by a DC capacitive discharge. The current travels through the 4mm bore of a boron nitride liner and subsequently ablates and ionizes the liner material. This results in a high density plasma with a large unidirectional bulk flow out of the source exit. The pulse length for the ET source has been optimized using a pulse forming network to have a duration of 1ms at full-width half maximum. The peak currents and maximum source energies seen in this system are 2kA and 5kJ. The goal of this work is to show that the ET source produces electron densities and heat fluxes that are comparable to transient events in future large magnetic confinement fusion devices. Heat flux, plasma temperature, and plasma density were determined for each test shot using infrared imaging and optical spectroscopy techniques. This work will compare the ET source output (heat flux, temperature, and density) with and without an applied magnetic field. Research sponsored by the Laboratory Directed Research and Development Program of Oak Ridge National Laboratory, managed by UT-Battelle, LLC, for the U. S. Department of Energy.

  15. Flow Conditions in a Mechanically Ventilated Room with a Convective Heat Source

    DEFF Research Database (Denmark)

    Heiselberg, Per; Nielsen, Peter V.

    1988-01-01

    The ventilation of a test room (LxWxH = 5.4x3.6x2.4 m) with a wall mounted heat source is investigated for two different air terminal devices.......The ventilation of a test room (LxWxH = 5.4x3.6x2.4 m) with a wall mounted heat source is investigated for two different air terminal devices....

  16. Ground-Source Integrated Heat Pump for Near-Zero Energy Houses: Technology Status Report

    Energy Technology Data Exchange (ETDEWEB)

    Murphy, Richard W [ORNL; Rice, C Keith [ORNL; Baxter, Van D [ORNL; Craddick, William G [ORNL

    2007-09-01

    . With the greater energy savings the cost of the more energy efficient components required for the IHP can be recovered more quickly than if they were applied to individual pieces of equipment to meet each individual energy service need. An IHP can be designed to use either outdoor air or geothermal resources (e.g., ground, ground water, surface water) as the environmental energy source/sink. Based on a scoping study of a wide variety of possible approaches to meeting the energy service needs for a ZEH, DOE selected the IHP concept as the most promising and has supported research directed toward the development of both air- and ground-source versions. This report describes the ground-source IHP (GS-IHP) design and includes the lessons learned and best practices revealed by the research and development (R&D) effort throughout. Salient features of the GS-IHP include a variable-speed rotary compressor incorporating a brushless direct current permanent magnet motor which provides all refrigerant compression, a variable-speed fan for the indoor section, a multiple-speed ground coil circuit pump, and a single-speed pump for water heating operation. Laboratory IHP testing has thus far used R-22 because of the availability of the needed components that use this refrigerant. It is expected that HFC R-410A will be used for any products arising from the IHP concept. Data for a variable-speed compressor that uses R-410A has been incorporated into the DOE/ORNL Mark VI Heat Pump Design Model (HPDM). HPDM was then linked to TRNSYS, a time-series-dependent simulation model capable of determining the energy use of building cooling and heating equipment as applied to a defined house on a sub-hourly basis. This provided a highly flexible design analysis capability for advanced heat pump equipment; however, the program also took a relatively long time to run. This approach was used with the initial prototype design reported in Murphy et al. (2007a) and in the business case analysis of

  17. Domestic Hot Water Production with Ground Source Heat Pump in Apartment Buildings

    Directory of Open Access Journals (Sweden)

    Jukka Yrjölä

    2015-08-01

    Full Text Available Producing domestic hot water (DHW with a ground source heat pump (GSHP is challenging due to the high temperature (HT of DHW. There are many studies proving the better performance of cascade heat pumps compared to single-stage heat pumps when the difference between the condensing and the evaporation temperature is large. In this system approach study, different GSHP arrangements are described and computationally compared. A two-stage heat pump arrangement is introduced in which water tanks of the heating system are utilized for warming up the DHW in two stages. It is shown that the electricity consumption with this two-stage system is approximately 31% less than with the single-stage heat pump and 12% less than with the cascade system. Further, both low temperature (LT and HT heat pumps can run alone, which is not common in cascade or other two-stage heat pumps. This is advantageous because the high loads of the space heating and DHW production are not simultaneous. Proper insulation of the DHW and recirculation pipe network is essential, and drying towel rails or other heating coils should be avoided when aiming for a high efficiency. The refrigerants in the calculations are R407C for the LT heat pump and R134a for the HT heat pump. Investment costs are excluded from calculations.

  18. Advanced variable speed air source integrated heat pump (AS-IHP) development - CRADA final report

    Energy Technology Data Exchange (ETDEWEB)

    Baxter, Van D. [Oak Ridge National Laboratory (ORNL), Oak Ridge, TN (United States); Rice, C. Keith [Oak Ridge National Laboratory (ORNL), Oak Ridge, TN (United States); Munk, Jeffrey D. [Oak Ridge National Laboratory (ORNL), Oak Ridge, TN (United States); Ally, Moonis Raza [Oak Ridge National Laboratory (ORNL), Oak Ridge, TN (United States); Shen, Bo [Oak Ridge National Laboratory (ORNL), Oak Ridge, TN (United States)

    2015-09-30

    Between August 2011 and September 2015, Oak Ridge National Laboratory (ORNL) and Nordyne, LLC (now Nortek Global HVAC LLC, NGHVAC) engaged in a Cooperative Research and Development Agreement (CRADA) to develop an air-source integrated heat pump (AS-IHP) system for the US residential market. Two generations of laboratory prototype systems were designed, fabricated, and lab-tested during 2011-2013. Performance maps for the system were developed using the latest research version of the DOE/ORNL Heat Pump Design Model, or HPDM, (Rice 1991; Rice and Jackson 2005; Shen et al 2012) as calibrated against the lab test data. These maps were the input to the TRNSYS (SOLAR Energy Laboratory, et al, 2010) system to predict annual performance relative to a baseline suite of equipment meeting minimum efficiency standards in effect in 2006 (combination of 13 SEER air-source heat pump (ASHP) and resistance water heater with Energy Factor (EF) of 0.9). Predicted total annual energy savings, while providing space conditioning and water heating for a tight, well insulated 2600 ft2 (242 m2) house at 5 U.S. locations, ranged from 46 to 61%, averaging 52%, relative to the baseline system (lowest savings at the cold-climate Chicago location). Predicted energy use for water heating was reduced 62 to 76% relative to resistance WH. Based on these lab prototype test and analyses results a field test prototype was designed and fabricated by NGHVAC. The unit was installed in a 2400 ft2 (223 m2) research house in Knoxville, TN and field tested from May 2014 to April 2015. Based on the demonstrated field performance of the AS-IHP prototype and estimated performance of a baseline system operating under the same loads and weather conditions, it was estimated that the prototype would achieve ~40% energy savings relative to the minimum efficiency suite. The estimated WH savings were >60% and SC mode savings were >50%. But estimated SH savings were only about 20%. It is believed that had the test

  19. Electron cyclotron resonance heating by magnetic filter field in a negative hydrogen ion source

    Energy Technology Data Exchange (ETDEWEB)

    Kim, June Young, E-mail: beacoolguy@snu.ac.kr; Cho, Won-Hwi; Dang, Jeong-Jeung; Chung, Kyoung-Jae, E-mail: jkjlsh1@snu.ac.kr; Hwang, Y. S. [Department of Nuclear Engineering, Seoul National University, Seoul 151-742 (Korea, Republic of)

    2016-02-15

    The influence of magnetic filter field on plasma properties in the heating region has been investigated in a planar-type inductively coupled radio-frequency (RF) H{sup −} ion source. Besides filtering high energy electrons near the extraction region, the magnetic filter field is clearly observed to increase the electron temperature in the heating region at low pressure discharge. With increasing the operating pressure, enhancement of electron temperature in the heating region is reduced. The possibility of electron cyclotron resonance (ECR) heating in the heating region due to stray magnetic field generated by a filter magnet located at the extraction region is examined. It is found that ECR heating by RF wave field in the discharge region, where the strength of an axial magnetic field is approximately ∼4.8 G, can effectively heat low energy electrons. Depletion of low energy electrons in the electron energy distribution function measured at the heating region supports the occurrence of ECR heating. The present study suggests that addition of axial magnetic field as small as several G by an external electromagnet or permanent magnets can greatly increase the generation of highly ro-vibrationally excited hydrogen molecules in the heating region, thus improving the performance of H{sup −} ion generation in volume-produced negative hydrogen ion sources.

  20. On the Design and Response of Domestic Ground-Source Heat Pumps in the UK

    Directory of Open Access Journals (Sweden)

    Chris Underwood

    2014-07-01

    Full Text Available The design and response of ground source heat pumps coupled to vertical closed loop arrays in UK domestic applications are investigated in this article. Two typical UK house types are selected as the vehicle for the study and a detailed dynamic thermal modelling method is used to arrive at time-series heating demands for the two houses. A new empirical heat pump model is derived using experimental data taking into account the deteriorating performance of the heat pump during periods of light load. The heat pump model is incorporated into an existing numerical ground model and completed with a classical effectiveness type heat exchange model of the closed loop array. The model is used to analyse array sizing and performance over an extended time period, as well as sensitivity of the design to soil conductivity and borehole heat exchanger resistance and sensitivity to over-sizing and part-load behavior of the heat pump. Results show that the UK’s standard for ground source design (the Microgeneration Certification Scheme may lead to under-estimated array sizes and that heating system over-sizing and deleterious part-load heat pump performance can add up to 20% to the electrical consumption of these systems.

  1. Numerical Prediction of Performance of Water Type Stirling Engine Considering Heat Exchange with Heat Sources

    Science.gov (United States)

    Yamaguchi, Yoshiyuki; Higuchi, Tetsuya

    Two different analytical models were developed on water type Stirling engine. One is the resonance model which qualitatively clarifies the relationship between performance and resonance tube length, and the other is the heat transfer model considering heat transfer between working gas and the tube walls of heating and cooling units. These analyses and experiments were carried out changing the resonance tube length variously, then it was confirmed that the resonance tube length which maximizes the water column amplitude of the power piston agrees well and the oscillations of water columns at that resonance tube length also agrees. In addition, a series of analysis using the heat transfer model was carried out with changing cross sectional area of the resonance tube, loss factors of the elbows, heat transfer area of heating and cooling unit, and pressure of working gas. By this numerical investigation, the effect on the resonance tube length and the work at the length in which these parameters maximize the amplitude of power piston water column was clarified.

  2. Verification of model for heat and mass transfer process in cross flow heat-source tower%叉流热源塔传热传质模型的建立及实验验证

    Institute of Scientific and Technical Information of China (English)

    文先太; 梁彩华; 刘成兴; 张小松

    2012-01-01

    As a new heat and mass transfer device, heat-source tower plays an important role in the heat-source tower heat pump system. Heat is absorbed from the ambient in winter and supplied to the evaporator of heat pump. There are some similarities and differences in heat and mass transfer between heat-source tower and cooling tower. Six primary differences are pointed out as follows: heat resistance, physical property of liquid, ratio of latent heat percentage, flow rate of circular water/liquid, effect of liquid float on the whole system, and direction and rate of heat transfer. Based on the similarities and differences of heat-source tower and cooling tower, the mathematical model of heat and mass transfer in the cross heat-source tower is proposed and the model is confirmed by experiments. Results show that the latent heat percentage of cross flow heat-source tower is less than 35% and the error of heat transfer rate between simulation and experiment is less than 10%. The model is accurate enough to simulate the heat transfer characteristic in the heat-source tower.%热源塔作为新型的热质交换设备,在热源塔热泵机组运行过程中起着重要作用.其在冬季运行时从空气中吸收热量,为热泵机组提供低品位热量.热源塔与冷却塔在传热传质上存在一定异同点,指出了冷却塔与热源塔在传热传质上存在热阻、液体物性、潜热换热量比例、循环水/液体流量、飘液对系统的影响、热量传递方向和换热量大小等方面的差异.根据热源塔与冷却塔差异建立叉流热源塔传热传质数学模型,并采用实验验证模型的准确性.结果表明叉流热源塔潜热百分比低于35%,模型结果与实验结果相比换热性能误差低于10%,该模型能够较为精确地对叉流热源塔换热性能进行模拟.

  3. Mixed convection from a discrete heat source in enclosures with two adjacent moving walls and filled with micropolar nanofluids

    Directory of Open Access Journals (Sweden)

    Sameh E. Ahmed

    2016-03-01

    Full Text Available This paper examines numerically the thermal and flow field characteristics of the laminar steady mixed convection flow in a square lid-driven enclosure filled with water-based micropolar nanofluids by using the finite volume method. While a uniform heat source is located on a part of the bottom of the enclosure, both the right and left sidewalls are considered adiabatic together with the remaining parts of the bottom wall. The upper wall is maintained at a relatively low temperature. Both the upper and left sidewalls move at a uniform lid-driven velocity and four different cases of the moving lid ordinations are considered. The fluid inside the enclosure is a water based micropolar nanofluid containing different types of solid spherical nanoparticles: Cu, Ag, Al2O3, and TiO2. Based on the numerical results, the effects of the dominant parameters such as Richardson number, nanofluid type, length and location of the heat source, solid volume fractions, moving lid orientations and dimensionless viscosity are examined. Comparisons with previously numerical works are performed and good agreements between the results are observed. It is found that the average Nusselt number along the heat source decreases as the heat source length increases while it increases when the solid volume fraction increases. Also, the results of the present study indicate that both the local and the average Nusselt numbers along the heat source have the highest value for the fourth case (C4. Moreover, it is observed that both the Richardson number and moving lid ordinations have a significant effect on the flow and thermal fields in the enclosure.

  4. Low Bandgap InAs-Based Thermophotovoltaic Cells for Heat-Electricity Conversion

    Science.gov (United States)

    Krier, A.; Yin, M.; Marshall, A. R. J.; Krier, S. E.

    2016-06-01

    The practical realization of thermophotovoltaic (TPV) cells, which can directly convert heat into electric power, is of considerable technological interest. However, most existing TPV cells require heat sources at temperatures of ˜1800°C. Here we report a low bandgap mid-infrared cell based on InAs and demonstrate TPV operation with heat sources at temperatures in the range 500-950°C. The maximum open circuit voltage ( V oc) and short circuit current density ( J sc) were measured as 0.06 V and 0.89 A cm-2 for a blackbody temperature of 950°C and an incident power density of 720 mW cm-2 without antireflection coating or electrode optimisation. TPV operation was obtained with heat sources at temperatures as low as 500°C, which represents progress towards energy scavenging and waste heat recovery applications.

  5. Research Progress on the Problem of Fluid, Heat and Energy Distribution near the Earthquake Source Area

    Institute of Scientific and Technical Information of China (English)

    Yan Rui; Jiang Changsheng; Shao Zhigang; Zhou Longquan; Li Yingchun

    2011-01-01

    As the basic problems in seismology, fluid, heat and energy distribution near earthquake sources during earthquake generation have been the leading subjects of concern to seismologists. Currently, more and more research shows fluid around earthquake source areas, which plays an important role in the process of earthquake preparation and generation. However, there is considerable controversy over the source of fluid in the deep crust. As for the problem of heat around earthquake source areas, different models have been proposed to explain the stress heat flow paradox. Among them, the dynamic weakening model has been thought to be the key to solving the heat flow paradox issue. After large earthquakes, energy distribution is directly related to friction heat. It is of timely and important practical significance to immediately implement deep drilling in-site surveying to gain understanding of fluid, friction heat and energy distribution during earthquake generation. The latest international progress in fluid, heat and energy distribution research has been reviewed in this paper which will bring important inspiration for the understanding of earthquake preparation and occurrence.

  6. Experimental investigation on water quality standard of Yangtze River water source heat pump.

    Science.gov (United States)

    Qin, Zenghu; Tong, Mingwei; Kun, Lin

    2012-01-01

    Due to the surface water in the upper reaches of Yangtze River in China containing large amounts of silt and algae, high content of microorganisms and suspended solids, the water in Yangtze River cannot be used for cooling a heat pump directly. In this paper, the possibility of using Yangtze River, which goes through Chongqing, a city in southwest China, as a heat source-sink was investigated. Water temperature and quality of the Yangtze River in the Chongqing area were analyzed and the performance of water source heat pump units in different sediment concentrations, turbidity and algae material conditions were tested experimentally, and the water quality standards, in particular surface water conditions, in the Yangtze River region that adapt to energy-efficient heat pumps were also proposed. The experimental results show that the coefficient of performance heat pump falls by 3.73% to the greatest extent, and the fouling resistance of cooling water in the heat exchanger increases up to 25.6% in different water conditions. When the sediment concentration and the turbidity in the river water are no more than 100 g/m3 and 50 NTU respectively, the performance of the heat pump is better, which can be used as a suitable river water quality standard for river water source heat pumps.

  7. Co-control of source and heat: the generation and distribution of hydrocarbons controlled by source rocks and heat%源热共控论

    Institute of Scientific and Technical Information of China (English)

    张功成

    2012-01-01

    Hydrocarbon generation is co-controlled by source rocks and heat, which are internal and external controlling factors, respectively. The combination of these two factors controls the generation, scale, phase (oil or gas) behavior and regional distribution pattern of hydrocarbons. The controlling factors of potential hydrocarbon source rocks include the type, abundance and scale of source rocks. Their heat field consists of hot, warm and cold models and there are 3 types of thermal evolution, I. E. Temperature-increasing, temperature-decreasing and complex multi-episode types. In potential hydrocarbon-generating sags, there are 4 kinds of combination between source rocks and heat, namely sufficient source and heat, sufficient source but deficient heat, deficient source but sufficient heat, and deficient source and heat. The sufficient source and heat combination can form hydrocarbon-generating sags including hydrocarbon-prolific or hydrocarbon-bearing sags, and the sufficient source but deficient heat combination or the deficient source but sufficient heat combination can also form hydrocarbon-generating or hydrocarbon-prolific sags on condition that source and heat can complement each other, while the deficient source and heat combination can not form hydrocarbon-bearing sags. In a hydrocarbon province co-controlled by source and heat, oil, gas or oil-gas layers generally have a spatially ordered distribution, which is characterized vertically by a lower oil and upper gas pattern or a lower gas and upper oil pattern, and laterally hy an inner and outer belt pattern, an inner and outer circle pattern, or a zoning pattern. The scale of hydrocarbon reserves in this hydrocarbon province depends mainly on the development of the sufficient source and heat sag, and hydrocarbon-bearing basins in China can be roughly classified into extra-prolific, prolific, medium, small and poor hydrocarbon-bearing basins.%源热共控油气形成,潜在烃源岩是油气形成的内因,

  8. The Possibility to use a Nuclear Power Plant as a Source of Electrical Energy and Heat

    Directory of Open Access Journals (Sweden)

    Tomasz Minkiewicz

    2014-09-01

    Full Text Available In this article issues concernig the possibility of nuclear power plant (NPP operation also as a source of heat, which means combined heat and power production, have been described. CHP work is possible and profitable only in those areas where high thermal power demand occurs, which means near city agglomerations such as Warsaw or the Tri-City. Two levels of thermal power delivered to the heating system have been considered. Preliminary technical and economic studies regarding NPP location by Żarnowiec Lake have confirmed the NPP potential to work as a primary source of heat in the heating network system, which would feed the regions of Wejherowo and Gdynia.

  9. Behavioral observations and operant procedures using microwaves as a heat source for young chicks

    Energy Technology Data Exchange (ETDEWEB)

    Morrison, W.D.; McMillan, I.; Bate, L.A.; Otten, L.; Pei, D.C.

    1986-08-01

    Four trials, using operant conditioning procedures, were conducted to study the response of chicks, housed at 16 C, to microwave or infrared heat. Microwave power density was 26 mW/cm2 in Trial 1, 13 mW/cm2 in Trial 2, and 10 mW/cm2 in Trials 3 and 4. Chicks voluntarily demanded between 28 and 63% as much heat (min heat/hr) from microwave source as from infrared source at all power densities. There was no correlation, however, between the ratio of heat demanded and the power density used. There were no significant differences in growth between infrared- or microwave-heated chicks. It is evident from these studies that 8-day-old broiler chicks are capable of associating the performance of a task with a thermal reward provided by the microwaves. They are also able to utilize these microwaves through operant conditioning without any visible detrimental effect to their health or behavior.

  10. Thermoeconomic Evaluation of Modular Organic Rankine Cycles for Waste Heat Recovery over a Broad Range of Heat Source Temperatures and Capacities

    Directory of Open Access Journals (Sweden)

    Markus Preißinger

    2017-02-01

    Full Text Available Industrial waste heat recovery by means of an Organic Rankine Cycle (ORC can contribute to the reduction of CO2 emissions from industries. Before market penetration, high efficiency modular concepts have to be developed to achieve appropriate economic value for industrial decision makers. This paper aims to investigate modularly designed ORC systems from a thermoeconomic point of view. The main goal is a recommendation for a suitable chemical class of working fluids, preferable ORC design and a range of heat source temperatures and thermal capacities in which modular ORCs can be economically feasible. For this purpose, a thermoeconomic model has been developed which is based on size and complexity parameters of the ORC components. Special emphasis has been laid on the turbine model. The paper reveals that alkylbenzenes lead to higher exergetic efficiencies compared to alkanes and siloxanes. However, based on the thermoeconomic model, the payback periods of the chemical classes are almost identical. With the ORC design, the developed model and the boundary conditions of this study, hexamethyldisiloxane is a suitable working fluid and leads to a payback period of less than 5 years for a heat source temperature of 400 to 600 °C and a mass flow rate of the gaseous waste heat stream of more than 4 kg/s.

  11. Marangoni convective MHD flow of SWCNT and MWCNT nanoliquids due to a disk with solar radiation and irregular heat source

    Science.gov (United States)

    Mahanthesh, B.; Gireesha, B. J.; Shashikumar, N. S.; Shehzad, S. A.

    2017-10-01

    Present study addresses the Marangoni transport of dissipating SWCNT and MWCNT nanofluids under the influence of magnetic force and radiation. A novel exponential space dependent heat source is considered. The flow is generated due to a disk with surface tension created by thermal gradient. The partial differential equations system governing the flow of carbon-water nanoliquids and heat transfer through Marangoni convection is established. Subsequent system is reduced to nonlinear ordinary boundary value problem via generalized Karman transformations. Numerical solutions are developed of the arising nonlinear problem via Runge-Kutta based shooting approach. Impacts of embedded parameters are focused on Nusselt number, velocity and heat transport distributions through graphical illustrations. Our simulations figured out that the heat transfer rate increased via Marangoni convection; however it is decayed by applied magnetic force. The temperature of SWCNT-H2O nanoliquid dominates MWCNT-H2O nanoliquid.

  12. Preliminary design study of an alternate heat source assembly for a Brayton isotope power system

    Science.gov (United States)

    Strumpf, H. J.

    1978-01-01

    Results are presented for a study of the preliminary design of an alternate heat source assembly (HSA) intended for use in the Brayton isotope power system (BIPS). The BIPS converts thermal energy emitted by a radioactive heat source into electrical energy by means of a closed Brayton cycle. A heat source heat exchanger configuration was selected and optimized. The design consists of a 10 turn helically wound Hastelloy X tube. Thermal analyses were performed for various operating conditions to ensure that post impact containment shell (PICS) temperatures remain within specified limits. These limits are essentially satisfied for all modes of operation except for the emergency cooling system for which the PICS temperatures are too high. Neon was found to be the best choice for a fill gas for auxiliary cooling system operation. Low cycle fatigue life, natural frequency, and dynamic loading requirements can be met with minor modifications to the existing HSA.

  13. A One-Source Approach for Estimating Land Surface Heat Fluxes Using Remotely Sensed Land Surface Temperature

    Directory of Open Access Journals (Sweden)

    Yongmin Yang

    2017-01-01

    Full Text Available The partitioning of available energy between sensible heat and latent heat is important for precise water resources planning and management in the context of global climate change. Land surface temperature (LST is a key variable in energy balance process and remotely sensed LST is widely used for estimating surface heat fluxes at regional scale. However, the inequality between LST and aerodynamic surface temperature (Taero poses a great challenge for regional heat fluxes estimation in one-source energy balance models. To address this issue, we proposed a One-Source Model for Land (OSML to estimate regional surface heat fluxes without requirements for empirical extra resistance, roughness parameterization and wind velocity. The proposed OSML employs both conceptual VFC/LST trapezoid model and the electrical analog formula of sensible heat flux (H to analytically estimate the radiometric-convective resistance (rae via a quartic equation. To evaluate the performance of OSML, the model was applied to the Soil Moisture-Atmosphere Coupling Experiment (SMACEX in United States and the Multi-Scale Observation Experiment on Evapotranspiration (MUSOEXE in China, using remotely sensed retrievals as auxiliary data sets at regional scale. Validated against tower-based surface fluxes observations, the root mean square deviation (RMSD of H and latent heat flux (LE from OSML are 34.5 W/m2 and 46.5 W/m2 at SMACEX site and 50.1 W/m2 and 67.0 W/m2 at MUSOEXE site. The performance of OSML is very comparable to other published studies. In addition, the proposed OSML model demonstrates similar skills of predicting surface heat fluxes in comparison to SEBS (Surface Energy Balance System. Since OSML does not require specification of aerodynamic surface characteristics, roughness parameterization and meteorological conditions with high spatial variation such as wind speed, this proposed method shows high potential for routinely acquisition of latent heat flux estimation

  14. Modeling tectonic heat flow and source rock maturity in the Rub' Al-Khali Basin (Saudi Arabia), with the help of GOCE satellite gravity data

    NARCIS (Netherlands)

    Abdul Fattah, R.; Meekes, S.; Bouman, J.; Ebbing, J.; Haagmans, R.

    2014-01-01

    A 3D basin modeling study was carried out to reconstruct the regional heat flow and source rock maturity in the Rub'al-Khali basin. Gravity gradient data from the GOCE satellite were used to model deep structures, such as the Moho interface. Tectonic heat flow was modeled using the GOCE-based Moho i

  15. Thermal energy storage system using phase change materials: Constant heat source

    Directory of Open Access Journals (Sweden)

    Reddy Meenakshi R.

    2012-01-01

    Full Text Available The usage of phase change materials (PCM to store the heat in the form of latent heat is increased, because large quantity of thermal energy is stored in smaller volumes. In the present experimental investigation paraffin and stearic acid are employed as PCMs in thermal energy storage (TES system to store the heat as sensible and latent heat also. A constant heat source is used to supply heat transfer fluid (HTF at constant temperature to the TES system. In the TES system PCMs are stored in the form of spherical capsules of 38 mm diameter made of high density poly ethylene (HDPE. The results of the investigation are related to the charging time and recovery of stored energy from the TES system.

  16. Dynamics of charged bulk viscous collapsing cylindrical source with heat flux

    Energy Technology Data Exchange (ETDEWEB)

    Shah, S.M.; Abbas, G. [The Islamia University of Bahawalpur, Department of Mathematics, Bahawalpur (Pakistan)

    2017-04-15

    In this paper, we have explored the effects of dissipation on the dynamics of charged bulk viscous collapsing cylindrical source which allows the out-flow of heat flux in the form of radiations. The Misner-Sharp formalism has been implemented to drive the dynamical equation in terms of proper time and radial derivatives. We have investigated the effects of charge and bulk viscosity on the dynamics of collapsing cylinder. To determine the effects of radial heat flux, we have formulated the heat transport equations in the context of Mueller-Israel-Stewart theory by assuming that thermodynamics viscous/heat coupling coefficients can be neglected within some approximations. In our discussion, we have introduced the viscosity by the standard (non-causal) thermodynamics approach. The dynamical equations have been coupled with the heat transport equation; the consequences of the resulting coupled heat equation have been analyzed in detail. (orig.)

  17. Heat pipes as perspective base elements of heat recovery in heat supply and ventilating systems

    Directory of Open Access Journals (Sweden)

    Matveev Andrey

    2017-01-01

    Full Text Available Thermotechnical characteristics of heat pipes are considered as high-efficient heat-transfer devices, which can provide energy-saving technologies for heat supply and ventilating systems and for different branches of industry. Thermotechnical and working (”performance capability” characteristics of heat pipes are investigated. By ”performance capability” of heat pipes and heat-transfer devices on heat pipes we mean the system state, where it can perform set functions and keep parameter values (thermal power, conductivity, thermal resistance, heat-transfer coefficient, temperature level and differential, etc. within the regulations of standardized specifications. The article presents theoretical and experimental methods of «gaslock» length determination on noncondensable gases during long-lasting tests of ammonia heat pipes made of aluminum shape АS – КRА 7.5 – R1 (alloy АD – 31. The paper gives results of research of thermotechnical characteristics of heat pipes in horizontal and vertical states (separate and as a set part while using different systems of thermal insulation. The obtained results of thermotechnical and resource tests show the advantages of ammonia heat pipes as basic elements for heat exchanger design in heating and ventilation systems.

  18. 地源热泵的地埋管群换热特性研究%Heat transfer characteristics of underground heat exchanger group in ground-source heat pump systems

    Institute of Scientific and Technical Information of China (English)

    於仲义; 陈焰华; 雷建平

    2012-01-01

    结合武汉某实际工程的地埋管群阵列布置情况和地源热泵系统的运行情况,对典型区域的地埋管群运行5年中的埋管换热特性进行了动态数值模拟和分析.提出了温度偏离度和换热保证度的概念,并研究了二者在地源热泵长期运行过程中的变化规律.建议尽量减小冷热负荷不平衡率,以保证地源热泵系统稳定可靠的运行.%Based on the arrangement of the underground heat exchanger group and the operation conditions of the ground-source heat pump system of an actual project in Wuhan, performs a dynamic numerical simulation and analysis of the heat transfer characteristics of the underground heat exchanger group during a five-year operation period in typical zones. Presents the concepts of temperature deviation degree and heat transfer assurance factor, and studies their variation in a long term operation process of ground-source heat pump systems. Proposes that the imbalance rate between cooling and heating load should be reduced as much as possible to ensure the stability and reliability of ground-source heat pump system operation.

  19. Fuel-efficiency of hydrogen and heat storage technologies for integration of fluctuating renewable energy sources

    DEFF Research Database (Denmark)

    Mathiesen, Brian Vad; Lund, Henrik

    2005-01-01

    This paper presents the methodology and results of analysing the use of different energy storage technologies in the task of integration of fluctuating renewable energy sources (RES) into the electricity supply. The analysis is done on the complete electricity system including renewable energy...... sources as well as power plants and CHP (Combined heat and power production). Emphasis is put on the need for ancillary services. Devices to store electricity as well as devices to store heat can be used to help the integration of fluctuating sources. Electricity storage technologies can be used...

  20. Location of energy source for coronal heating on the photosphere

    Science.gov (United States)

    Hong, Zhen-Xiang; Yang, Xu; Wang, Ya; Ji, Kai-Fan; Ji, Hai-Sheng; Cao, Wen-Da

    2017-02-01

    It is reported that ultra-fine dynamic ejections along magnetic loops of an active region originate from intergranular lanes and they are associated with subsequent heating in the corona. As continuing work, we analyze the same set of data but focus on a quiet region and the overlying EUV/UV emission as observed by the Atmospheric Imaging Assembly (AIA) on board Solar Dynamics Observatory (SDO). We find that there appear to be dark patches scattered across the quiet region and the dark patches always stay along intergranular lanes. Over the dark patches, the average UV/EUV emission at 131, 171, 304 and 1600 Å (middle temperature) is more intense than that of other regions and EUV brightness is negatively correlated with 10830 Å intensity, though, such a trend does not exist for high temperature lines at 94, 193, 211 and 335 Å. For the same quiet region, where both TiO 7057 Å broad band images and 10830 Å filtergrams are available, contours for the darkest lane areas on TiO images and dark patches on 10830 Å filtergrams frequently differ in space. The results suggest that the dark patches do not simply reflect the areas with the darkest lanes but are associated with a kind of enhanced absorption (EA) at 10830 Å. A strict definition for EA with narrow band 10830 Å filtergrams is found to be difficult. In this paper, we define enhanced absorption patches (EAPs) of a quiet region as the areas where emission is less than ∼90% of the mean intensity of the region. The value is equivalent to the average intensity along thin dark loops connecting two moss regions of the active region. A more strict definition for EAPs, say 88%, gives even more intense UV/EUV emission over those in the middle temperature range. The results provide further observational evidence that energy for heating the upper solar atmosphere comes from the intergranular lane area where the magnetic field is constantly brought in by convection motion in granules.

  1. Investigation on A Ground Source Heat Pump System Integrated With Renewable Sources

    OpenAIRE

    Qian, Defeng; Niu, Fuxin; Kavanaugh, Steven; O'Neill, Zheng

    2016-01-01

    Buildings consumed 40% of the energy and represented 40% of the carbon emissions in the United States. This is more than any other sector of the U.S. economy, including transportation and industry. About 24% of all energy used in the nation is for space heating, cooling and water heating in buildings. Enhancing building efficiency represents one of the easiest, most immediate and most cost effective ways to reduce carbon emissions. One of energy efficient and environment friendly technologies...

  2. High Performance Cascading Adsorption Refrigeration Cycle with Internal Heat Recovery Driven by a Low Grade Heat Source Temperature

    Directory of Open Access Journals (Sweden)

    Yuki Ueda

    2009-11-01

    Full Text Available This paper presents the performance of an advanced cascading adsorption cycle that utilizes a driven heat source temperature between 90–130 ºC. The cycle consists of four beds that contain silica gel as an adsorber fill. Two of the beds work in a single stage cycle that is driven by an external heat source, while the other two beds work in a mass recovery cycle that is driven by waste heat of sensible and adsorption heat of the high temperature cycle. The performances, in terms of the coefficient of performance (COP and the specific cooling power (SCP, are compared with conventional cascading-without-mass-recovery and single-stage cycles. The paper also presents the effect of the adsorbent mass on performance. The results show that the proposed cycle with mass recovery produces as high of a COP as the COP that is produced by the conventional cascading cycle. However, it produces a lower SCP than that of the single-stage cycle.

  3. An inductively heated hot cavity catcher laser ion source

    CERN Document Server

    Reponen, M; Pohjalainen, I; Rothe, S; Savonen, M; Sonnenschein, V; Voss, A

    2015-01-01

    An inductively heated hot cavity catcher has been constructed for the production of low-energy ion beams of exotic, neutron-deficient Agisotopes. A proof-of-principle experiment has been realized by implanting primary 107Ag21+ ions from a heavy-ion cyclotron into a graphite catcher. A variable-thickness nickel foil was used to degrade the energy of the primary beam in order to mimic the implantation depth expected from the heavy-ion fusion-evaporation recoils of N = Z94Ag. Following implantation, the silver atoms diffused out of the graphite and effused into the catcher cavity and transfer tube, where they were resonantly laser ionized using a three-step excitation and ionization scheme. Following mass separation, the ions were identified by scanning the frequency of the first resonant excitation step while recording the ion count rate. Ion release time profiles were measured for different implantation depths and cavity temperatures with the mean delay time varying from 10 to 600 ms. In addition, the diffusio...

  4. Optimal Heating in Heat-Treatment Process Based on Grey Asynchronous Particle Swarm Optimization

    Institute of Scientific and Technical Information of China (English)

    2012-01-01

    To ensure plate heating quality and reduce energy consumption in heat-treatment process, optimal heating for plates in a roller hearth furnace was investigated and a new strategy for heating procedure optimization was developed. During solving process, plate temperature forecast model based on heat transfer mechanics was established to calculate plate temperature with the assumed heating procedure. In addition, multi-objective feature of optimal heating was analyzed. And the method, which is composed of asynchronous particle swarm optimization and grey relational analysis, was adopted for solving the multi-objective problem. The developed strategy for optimizing heating has been applied to the mass production. The result indicates that the absolute plate discharging temperature deviation between measured value and target value does not exceed ± 8 ℃, and the relative deviation is less than ± 0.77%.

  5. Personalized recommendation based on heat bidirectional transfer

    Science.gov (United States)

    Ma, Wenping; Feng, Xiang; Wang, Shanfeng; Gong, Maoguo

    2016-02-01

    Personalized recommendation has become an increasing popular research topic, which aims to find future likes and interests based on users' past preferences. Traditional recommendation algorithms pay more attention to forecast accuracy by calculating first-order relevance, while ignore the importance of diversity and novelty that provide comfortable experiences for customers. There are some levels of contradictions between these three metrics, so an algorithm based on bidirectional transfer is proposed in this paper to solve this dilemma. In this paper, we agree that an object that is associated with history records or has been purchased by similar users should be introduced to the specified user and recommendation approach based on heat bidirectional transfer is proposed. Compared with the state-of-the-art approaches based on bipartite network, experiments on two benchmark data sets, Movielens and Netflix, demonstrate that our algorithm has better performance on accuracy, diversity and novelty. Moreover, this method does better in exploiting long-tail commodities and cold-start problem.

  6. Joule Heating, Particle Precipitation and Dynamical Heating as Possible Tidal Sources in the Antarctic Winter Lower Thermosphere

    Science.gov (United States)

    Fong, W.; Chu, X.; Lu, X.; Chen, C.; Yu, Z.; Fuller-Rowell, T. J.; Richmond, A. D.; Codrescu, M.

    2014-12-01

    Winter temperature tides observed by lidar at McMurdo (77.8°S, 166.7°E), Antarctica, show less than 3 K diurnal and semidiurnal tidal amplitude below 100 km. However, above 100 km, the diurnal and semidiurnal tidal amplitudes grow super-exponentially and can reach at least 15 K near 110 km, which are exceeding that of the freely propagating tides originating from the lower atmosphere. Such fast growth exists for all Kp index cases and diurnal amplitude increases to 15-30 K at 110 km with larger Kp indices corresponding to larger tidal amplitudes and faster growth rates. Combining with the slopes of diurnal tidal phases being steeper above 100 km, and the tidal phases barely changing with altitude from 100 to 106 km, it indicates that in-situ tidal sources may exist near or above 100 km. In this paper, we utilize the coupled thermosphere ionosphere plasmasphere electrodynamics (CTIPe) model to investigate possible sources/mechanisms that lead to the fast amplitude growth of tides in the polar winter region. Joule heating, particle precipitation, and dynamical heating are likely to be the dominant thermospheric tidal sources, according to CTIPe model. Interestingly, the CTIPe tidal amplitudes induced by these sources form a concentric pattern with its center located at the geomagnetic pole, implying that the geomagnetic activity may play an important role. Furthermore, dynamical heating, which includes adiabatic heating/cooling and vertical advection, is likely to be the explanation of the fast growth of diurnal tidal amplitudes even under quiet condition of geomagnetic activity as observed by lidar. We also found that the tides propagating from the lower atmosphere is a minor factor for the fast increase of thermospheric diurnal tides in Antarctica.

  7. Earliest Deadline Control of a Group of Heat Pumps with a Single Energy Source

    Directory of Open Access Journals (Sweden)

    Jiří Fink

    2016-07-01

    Full Text Available In this paper, we develop and investigate the optimal control of a group of 104 heat pumps and a central Combined Heat and Power unit (CHP. The heat pumps supply space heating and domestic hot water to households. Each house has a buffer for domestic hot water and a floor heating system for space heating. Electricity for the heat pumps is generated by a central CHP unit, which also provides thermal energy to a district heating system. The paper reviews recent smart grid control approaches for central and distributed levels. An online algorithm is described based on the earliest deadline first theory that can be used on the aggregator level to control the CHP and to give signals to the heat pump controllers if they should start or should wait. The central controller requires only a limited amount of privacy-insensitive information from the heat pump controllers about their deadlines, which the heat pump controllers calculate for themselves by model predictions. In this way, a robust heat pump and CHP control is obtained, which is able to minimize energy demand and results in the desired thermal comfort for the households. The simulations demonstrate fast computation times due to minor computational and communication overheads.

  8. Study on the Performance of a Ground Source Heat Pump System Assisted by Solar Thermal Storage

    Directory of Open Access Journals (Sweden)

    Yu Jin Nam

    2015-11-01

    Full Text Available A ground source heat pump system (GSHPS utilizes a relatively stable underground temperature to achieve energy-saving for heating and cooling in buildings. However, continuous long-term operation will reduce the soil temperature in winter, resulting in a decline in system performance. In this research, in order to improve the system performance of a GSHPS, a ground heat pump system integrated with solar thermal storage was developed. This solar-assisted ground heat pump system (SAGHPS can both maintain the balance of the soil temperature effectively and achieve higher system performance than the conventional system. In this paper, in order to examine the characteristics of the system, a dynamic simulation was conducted under various conditions. The results of our case study provide specific operation data such as heat exchange rate, heat source temperature, and heat pump COP. As a result, the heat pump COP of SAGHPS was 4.7%, 9.3% higher than that of the GSHPS.

  9. Solid Waste from Swine Wastewater as a Fuel Source for Heat Production

    Directory of Open Access Journals (Sweden)

    Myung-Ho Park

    2012-11-01

    Full Text Available This study was to evaluate the feasibility of recycling the solids separated from swine wastewater treatment process as a fuel source for heat production and to provide a data set on the gas emissions and combustion properties. Also, in this study, the heavy metals in ash content were analyzed for its possible use as a fertilizer. Proximate analysis of the solid recovered from the swine wastewater after flocculation with organic polymer showed high calorific (5,330.50 kcal/kg and low moisture (15.38% content, indicating that the solid separated from swine wastewater can be used as an alternative fuel source. CO and NOx emissions were found to increase with increasing temperature. Combustion efficiency of the solids was found to be stable (95 to 98% with varied temperatures. Thermogravimetry (TG and differential thermal analysis (DTA showed five thermal effects (four exothermic and one endothermic, and these effects were distinguished in three stages, water evaporation, heterogeneous combustion of hydrocarbons and decomposition reaction. Based on the calorific value and combustion stability results, solid separated from swine manure can be used as an alternative source of fuel, however further research is still warranted regarding regulation of CO and NOx emissions. Furthermore, the heavy metal content in ash was below the legal limits required for its usage as fertilizer.

  10. Study of heat transfer in CI engine using heat transfer correlation based on intake jet velocity

    Energy Technology Data Exchange (ETDEWEB)

    Sharief, A. [Sri Siddharhta Inst. of Technology, Tumkur, Karnataka (India); Samaga, B.S.; Shrinivas Rao, B.R. [Nitte Mahalinga Adyantaya Institute of Technology, Karkala, Karnataka (India); JAntonyc, A. [Sahyadri Inst. of Technology, Mangalore, Karnataka (India)

    2009-07-01

    A reliable heat transfer formulation is needed to simulate reciprocating combustion engines. In order to reduce heat loss and improve thermal efficiency, it is necessary to calculate the rate of heat transfer from the working fluid to the combustion chamber walls. The thermal stresses in the engine components must also be determined. In this study, the author calculated heat transfer coefficient in a diesel engine using a heat transfer correlation based on intake jet velocity instead of mean piston speed. Experiments were conducted in a diesel engine with natural aspiration of hot air at 150 to 300 degrees C. Peak temperature was 1100 degrees C at various loads. The convective heat transfer coefficient and radiative heat transfer coefficient component was also determined separately at various loads. This model based on intake jet velocity instead of mean piston speed was found to be more realistic when considering the influence of gas velocities on the thermal boundary layer thickness. 11 refs., 12 figs.

  11. Electrocaloric devices based on thini-film heat switches

    Energy Technology Data Exchange (ETDEWEB)

    Epstein, Richard I [Los Alamos National Laboratory; Malloy, Kevin J [UNM

    2009-01-01

    We describe a new approach to refrigeration and electrical generation that exploits the attractive properties of thin films of electrocaloric materials. Layers of electrocaloric material coupled with thin-film heat switches can work as either refrigerators or electrical generators, depending on the phasing of the applied voltages and heat switching. With heat switches based on thin layers of liquid crystals, the efficiency of these thin-film heat engines can be at least as high as that of current thermoelectric devices. Advanced heat switches would enable thin-film heat engines to outperform conventional vaporcompression devices.

  12. GIS based analysis of future district heating potential in Denmark

    DEFF Research Database (Denmark)

    Nielsen, Steffen; Möller, Bernd

    2013-01-01

    The physical placement of buildings is important when determining the potential for DH (district heating). Good locations for DH are mainly determined by having both a large heat demand within a certain area and having access to local heat resources. In recent years, the locations of buildings...... in Denmark have been mapped in a heat atlas which includes all buildings and their heat demands. This article focuses on developing a method for assessing the costs associated with supplying these buildings with DH. The analysis is based on the existing DH areas in Denmark. By finding the heat production...

  13. Salmonella source attribution based on microbial subtyping

    DEFF Research Database (Denmark)

    Barco, Lisa; Barrucci, Federica; Olsen, John Elmerdahl

    2013-01-01

    Source attribution of cases of food-borne disease represents a valuable tool for identifying and prioritizing effective food-safety interventions. Microbial subtyping is one of the most common methods to infer potential sources of human food-borne infections. So far, Salmonella microbial subtyping...... source attribution models have been implemented by using serotyping and phage-typing data. Molecular-based methods may prove to be similarly valuable in the future, as already demonstrated for other food-borne pathogens like Campylobacter. This review assesses the state of the art concerning Salmonella...... in the context of their potential applicability for Salmonella source attribution studies....

  14. Viscoelastic Fluid over a Stretching Sheet with Electromagnetic Effects and Nonuniform Heat Source/Sink

    Directory of Open Access Journals (Sweden)

    Kai-Long Hsiao

    2010-01-01

    Full Text Available A magnetic hydrodynamic (MHD of an incompressible viscoelastic fluid over a stretching sheet with electric and magnetic dissipation and nonuniform heat source/sink has been studied. The buoyant effect and the electric number E1 couple with magnetic parameter M to represent the dominance of the electric and magnetic effects, and adding the specific item of nonuniform heat source/sink is presented in governing equations which are the main contribution of this study. The similarity transformation, the finite-difference method, Newton method, and Gauss elimination method have been used to analyze the present problem. The numerical solutions of the flow velocity distributions, temperature profiles, and the important wall unknown values of f''(0 and θ'(0 have been carried out. The parameter Pr, E1, or Ec can increase the heat transfer effects, but the parameter M or A* may decrease the heat transfer effects.

  15. Analysis of Fuel Cell Driven Ground Source Heat Pump Systems in Community Buildings

    Directory of Open Access Journals (Sweden)

    Jong-Keun Shin

    2013-05-01

    Full Text Available In the present study, a fuel cell driven ground source heat pump (GSHP system is applied in a community building and heat pump system performance is analyzed by computational methods. Conduction heat transfer between the brine pipe and ground is analyzed by TEACH code in order to predict the performance of the heat pump system. The predicted coefficient of performance (COP of the heat pump system and the energy cost were compared with the variation of the location of the objective building, the water saturation rate of the soil, and the driven powers of the heat pump system. Compared to the late-night electricity driven system, a significant reduction of energy cost can be accomplished by employing the fuel cell driven heat pump system. This is due to the low cost of electricity production of the fuel cell system and to the application of the recovered waste heat generated during the electricity production process to the heating of the community building.

  16. Thermodynamic inspection of concrete using a controlled heat source

    Science.gov (United States)

    Milne, James M.

    1990-10-01

    Concrete is not quite such a non-destructable material as many are led to believe. It can deteriorate with time due to changes in the chemistry, the effect of moisture penetration and the corrosion of reinforcing steel bars. Much of this damage occurs relatively close to the surface, sometimes revealed by discolourations or the presence of cracks and sometimes as spallation when the corrosion products of steel cause delamination of the near surface concrete. These effects may occur in good quality concrete but their severity and rapidity of onset may be enhanced by fabrication defects when aggregates may not be to specification or the packing conditions cause porosity. It may thus be months or even years afterwards that these defects come to light. As a consequence a new industry has been formed to inspect concrete structures which may include X-ray equipment, linac accelerators, gamma isotope sources, ultrasonics, radar and of course thermography. Each of these nethods will have their own particular attractive features and merits. But most of these activities tend to be used more as a "fire fighting" service than as one ensuring regular maintenance of critical structures or even as quality control of structures during building. Quite often it seems that Non-destructive Testing is turned into a litigation service for dissatisfied customers and thermography is no stranger to this topic. It is heartening to see that the ASTM organisation in the USA and British Standards are encouraging and developing suitable standards for the inspection of concrete by thermographic techniques.

  17. MUNICIPAL WASTEWATER AS AN SOURCE OF WASTE HEAT – CASE STUDY

    Directory of Open Access Journals (Sweden)

    Alina Żogała

    2016-09-01

    Full Text Available The paper describes the possibility of useing treated wastewater from municipal waste water treatment plant as a waste heat source. Presented and calculated theoretical possibilities of receiving heat takes into account the indirect and direct method. A variant case study was carried out on the example of municipal mechanical and biological wastewater treatment plant Ruptawa belonging to Jastrzębskie Przedsiębiorstwo Wodociągów i Kanalizacji (voivodship Silesia, Jastrzębie City.

  18. Parallel Operation Characteristics Analysis of Sewage Source Heat Pump Units in Winter

    Institute of Scientific and Technical Information of China (English)

    庄兆意; 张承虎; 王海燕; 孙德兴

    2010-01-01

    Sewage source heat pump unit operates under partial load most of the time, and study on the law of coefficient of performance (COP) of the unit varying with load ratio can provide basis for the heat pump units running in high efficiency. A mathematical model determining COP, evaporation temperature and condensation temperature of a single unit was proposed. Under the condition of uniform load distribution, the model was established according to different ways of bearing partial load with the same type multi...

  19. Increase of COP for heat transformer in water purification systems. Part II - Without increasing heat source temperature

    Energy Technology Data Exchange (ETDEWEB)

    Romero, R.J. [Centro de Investigacion en Ingenieria y Ciencias Aplicadas, Universidad Autonoma del Estado de Morelos, Av. Universidad 1001, Col. Chamilpa, C.P. 62209 Cuernavaca, Morelos (Mexico)]. E-mail: rosenberg@uaem.mx; Siqueiros, J. [Centro de Investigacion en Ingenieria y Ciencias Aplicadas, Universidad Autonoma del Estado de Morelos, Av. Universidad 1001, Col. Chamilpa, C.P. 62209 Cuernavaca, Morelos (Mexico); Huicochea, A. [Posgrado en Ingenieria y Ciencias Aplicadas, Universidad Autonoma del Estado de Morelos, Av. Universidad 1001, Col. Chamilpa, C.P. 62209 Cuernavaca, Morelos (Mexico)

    2007-04-15

    The integration of a water purification system allows a heat transformer to increase the actual coefficient of performance, by the reduction of the amount of heat supplied by unit of heat. A new defined COP called COP{sub WP} is proposed for the present system, which considers the fraction of heat recycled. Simulation with proven software compares the performance of the modeling of an absorption heat transformer for water purification (AHTWP) operating with water/lithium bromide, as working fluid-absorbent pair. Plots of enthalpy-based coefficients of performance (COP{sub ET}) and water purification coefficient of performance (COP{sub WP}) are shown against absorber temperature for several thermodynamic operating conditions. The results showed that the proposed (AHTWP) system is capable of increasing the original value of COP{sub ET} up to 1.6 times its original value by recycling energy from a water purification system. The proposed COP{sub WP} allows increments for COP values from any experimental data for water purification or for any other distillation system integrated to a heat transformer, regardless of actual COP{sub A} value or working fluid-absorbent pair.

  20. Increase of COP for heat transformer in water purification systems. Pt. 2 - Without increasing heat source temperature

    Energy Technology Data Exchange (ETDEWEB)

    Romero, R.J.; Siqueiros, J. [Centro de Investigacion en Ingenieria y Ciencias Aplicadas, Universidad Autonoma del Estado de Morelos, Av. Universidad 1001, Col. Chamilpa, C.P. 62209 Cuernavaca, Morelos (Mexico); Huicochea, A. [Posgrado en Ingenieria y Ciencias Aplicadas, Universidad Autonoma del Estado de Morelos, Av. Universidad 1001, Col. Chamilpa, C.P. 62209 Cuernavaca, Morelos (Mexico)

    2007-04-15

    The integration of a water purification system allows a heat transformer to increase the actual coefficient of performance, by the reduction of the amount of heat supplied by unit of heat. A new defined COP called COP{sub WP} is proposed for the present system, which considers the fraction of heat recycled. Simulation with proven software compares the performance of the modeling of an absorption heat transformer for water purification (AHTWP) operating with water/lithium bromide, as working fluid-absorbent pair. Plots of enthalpy-based coefficients of performance (COP{sub ET}) and water purification coefficient of performance (COP{sub WP}) are shown against absorber temperature for several thermodynamic operating conditions. The results showed that the proposed (AHTWP) system is capable of increasing the original value of COP{sub ET} up to 1.6 times its original value by recycling energy from a water purification system. The proposed COP{sub WP} allows increments for COP values from any experimental data for water purification or for any other distillation system integrated to a heat transformer, regardless of actual COP{sub A} value or working fluid-absorbent pair. (author)

  1. High-frequency torsional Alfvén waves as an energy source for coronal heating

    Science.gov (United States)

    Srivastava, Abhishek Kumar; Shetye, Juie; Murawski, Krzysztof; Doyle, John Gerard; Stangalini, Marco; Scullion, Eamon; Ray, Tom; Wójcik, Dariusz Patryk; Dwivedi, Bhola N.

    2017-03-01

    The existence of the Sun’s hot atmosphere and the solar wind acceleration continues to be an outstanding problem in solar-astrophysics. Although magnetohydrodynamic (MHD) modes and dissipation of magnetic energy contribute to heating and the mass cycle of the solar atmosphere, yet direct evidence of such processes often generates debate. Ground-based 1-m Swedish Solar Telescope (SST)/CRISP, Hα 6562.8 Å observations reveal, for the first time, the ubiquitous presence of high frequency (~12–42 mHz) torsional motions in thin spicular-type structures in the chromosphere. We detect numerous oscillating flux tubes on 10 June 2014 between 07:17 UT to 08:08 UT in a quiet-Sun field-of-view of 60” × 60” (1” = 725 km). Stringent numerical model shows that these observations resemble torsional Alfvén waves associated with high frequency drivers which contain a huge amount of energy (~105 W m‑2) in the chromosphere. Even after partial reflection from the transition region, a significant amount of energy (~103 W m‑2) is transferred onto the overlying corona. We find that oscillating tubes serve as substantial sources of Alfvén wave generation that provide sufficient Poynting flux not only to heat the corona but also to originate the supersonic solar wind.

  2. High-frequency torsional Alfvén waves as an energy source for coronal heating

    Science.gov (United States)

    Srivastava, Abhishek Kumar; Shetye, Juie; Murawski, Krzysztof; Doyle, John Gerard; Stangalini, Marco; Scullion, Eamon; Ray, Tom; Wójcik, Dariusz Patryk; Dwivedi, Bhola N.

    2017-01-01

    The existence of the Sun’s hot atmosphere and the solar wind acceleration continues to be an outstanding problem in solar-astrophysics. Although magnetohydrodynamic (MHD) modes and dissipation of magnetic energy contribute to heating and the mass cycle of the solar atmosphere, yet direct evidence of such processes often generates debate. Ground-based 1-m Swedish Solar Telescope (SST)/CRISP, Hα 6562.8 Å observations reveal, for the first time, the ubiquitous presence of high frequency (~12–42 mHz) torsional motions in thin spicular-type structures in the chromosphere. We detect numerous oscillating flux tubes on 10 June 2014 between 07:17 UT to 08:08 UT in a quiet-Sun field-of-view of 60” × 60” (1” = 725 km). Stringent numerical model shows that these observations resemble torsional Alfvén waves associated with high frequency drivers which contain a huge amount of energy (~105 W m−2) in the chromosphere. Even after partial reflection from the transition region, a significant amount of energy (~103 W m−2) is transferred onto the overlying corona. We find that oscillating tubes serve as substantial sources of Alfvén wave generation that provide sufficient Poynting flux not only to heat the corona but also to originate the supersonic solar wind. PMID:28256538

  3. Nanofluids and a method of making nanofluids for ground source heat pumps and other applications

    Science.gov (United States)

    Olson, John Melvin

    2013-11-12

    This invention covers nanofluids. Nanofluids are a combination of particles between 1 and 100 nanometers, a surfactant and the base fluid. The nanoparticles for this invention are either pyrogenic nanoparticles or carbon nanotubes. These nanofluids improve the heat transfer of the base fluids. The base fluid can be ethylene glycol, or propylene glycol, or an aliphatic-hydrocarbon based heat transfer fluid. This invention also includes a method of making nanofluids. No surfactant is used to suspend the pyrogenic nanoparticles in glycols.

  4. An evaluation of alternate production methods for Pu-238 general purpose heat source pellets

    Energy Technology Data Exchange (ETDEWEB)

    Mark Borland; Steve Frank

    2009-06-01

    For the past half century, the National Aeronautics and Space Administration (NASA) has used Radioisotope Thermoelectric Generators (RTG) to power deep space satellites. Fabricating heat sources for RTGs, specifically General Purpose Heat Sources (GPHSs), has remained essentially unchanged since their development in the 1970s. Meanwhile, 30 years of technological advancements have been made in the applicable fields of chemistry, manufacturing and control systems. This paper evaluates alternative processes that could be used to produce Pu 238 fueled heat sources. Specifically, this paper discusses the production of the plutonium-oxide granules, which are the input stream to the ceramic pressing and sintering processes. Alternate chemical processes are compared to current methods to determine if alternative fabrication processes could reduce the hazards, especially the production of respirable fines, while producing an equivalent GPHS product.

  5. Eigenvalue approach to fractional order generalized magneto-thermoelastic medium subjected to moving heat source

    Energy Technology Data Exchange (ETDEWEB)

    Abbas, Ibrahim A., E-mail: aabbas5@kau.edu.sa [Department of Mathematics, Faculty of Science and Arts-Khulais, King Abdulaziz University, Jeddah (Saudi Arabia); Department of mathematics, Faculty of Science, Sohag University, Sohag (Egypt)

    2015-03-01

    In the present work, we consider the problem of fractional order thermoelastic interaction in a material placed in a magnetic field and subjected to a moving plane of heat source. The basic equations have been written in the form of a vector–matrix differential equation in the Laplace transform domain, which is then solved by an eigenvalue approach. The inverse Laplace transforms are computed numerically and some comparisons have been shown in figures to estimate the effect of each of the fractional order, heat source velocity, time and the magnetic field and parameters. - Highlights: • The problem of fractional order thermoelastic interaction in a material placed in a magnetic field and subjected to a moving plane of heat source. • The eigenvalue approach gives exact solution in the Laplace domain without any assumed restrictions on the actual physical quantities. • Numerical results for the temperature, displacement and the stress distributions are represented graphically.

  6. STAR: The Secure Tranportable Autonomous Reactor system, Encapsulated Fission Heat Source. Progress report for period terminating March 31, 2000

    Energy Technology Data Exchange (ETDEWEB)

    Greenspan, Ehud

    2000-04-24

    Significant progress has been made since the beginning of this project, in September 1999. Part of the project findings are described in References 1 and 2. So far we have found no ''show-stopper''. In fact, based on the findings accumulated so far it appears to us that the Encapsulated Nuclear Heat Source (ENHS) is technologically feasible and looks even more attractive than initially conceived.

  7. Humans as a Source of Heat and Air Pollution

    DEFF Research Database (Denmark)

    Hyldgård, Carl-Erik

    This is the first part of a planned research into the effect of the human being on the indoor climate. The results are among other things intended for CFD calculations. This part deals with the influence from breathing, smoking, bioeffluents and vapour. The results are mainly based on measurement...... around a breathing thermal model placed in three fundamentally different types of indoor climates: - Quiet surroundings, no ventilation - Displacement ventilation - Constant horizontal flow...

  8. Power optimization of chemically driven heat engine based on first and second order reaction kinetic theory and probability theory

    Science.gov (United States)

    Zhang, Lei; Chen, Lingen; Sun, Fengrui

    2016-03-01

    The finite-time thermodynamic method based on probability analysis can more accurately describe various performance parameters of thermodynamic systems. Based on the relation between optimal efficiency and power output of a generalized Carnot heat engine with a finite high-temperature heat reservoir (heat source) and an infinite low-temperature heat reservoir (heat sink) and with the only irreversibility of heat transfer, this paper studies the problem of power optimization of chemically driven heat engine based on first and second order reaction kinetic theory, puts forward a model of the coupling heat engine which can be run periodically and obtains the effects of the finite-time thermodynamic characteristics of the coupling relation between chemical reaction and heat engine on the power optimization. The results show that the first order reaction kinetics model can use fuel more effectively, and can provide heat engine with higher temperature heat source to increase the power output of the heat engine. Moreover, the power fluctuation bounds of the chemically driven heat engine are obtained by using the probability analysis method. The results may provide some guidelines for the character analysis and power optimization of the chemically driven heat engines.

  9. Optimal Homotopy Asymptotic Solution for Exothermic Reactions Model with Constant Heat Source in a Porous Medium

    Directory of Open Access Journals (Sweden)

    Fazle Mabood

    2015-01-01

    Full Text Available The heat flow patterns profiles are required for heat transfer simulation in each type of the thermal insulation. The exothermic reaction models in porous medium can prescribe the problems in the form of nonlinear ordinary differential equations. In this research, the driving force model due to the temperature gradients is considered. A governing equation of the model is restricted into an energy balance equation that provides the temperature profile in conduction state with constant heat source on the steady state. The proposed optimal homotopy asymptotic method (OHAM is used to compute the solutions of the exothermic reactions equation.

  10. An Open-Source Based ITS Platform

    DEFF Research Database (Denmark)

    Andersen, Ove; Krogh, Benjamin Bjerre; Torp, Kristian

    2013-01-01

    In this paper, a complete platform used to compute travel times from GPS data is described. Two approaches to computing travel time are proposed one based on points and one based on trips. Overall both approaches give reasonable results compared to existing manual estimated travel times. However......, the trip-based approach requires more GPS data and of a higher quality than the point-based approach. The platform has been completely implemented using open-source software. The main conclusion is that large quantity of GPS data can be managed, with a limited budget and that GPS data is a good source...

  11. Demonstration of a non-contact x-ray source using an inductively heated pyroelectric accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Klopfer, Michael; Satchouk, Vladimir; Cao, Anh; Wolowiec, Thomas; Alivov, Yahya; Molloi, Sabee, E-mail: symolloi@uci.edu

    2015-04-11

    X-ray emission from pyroelectric sources can be produced through non-contact thermal cycling using induction heating. In this study, we demonstrated a proof of concept non-contact x-ray source powered via induction heating. An induction heater operating at 62.5 kHz provided a total of 6.5 W of delivered peak thermal power with 140 V DC of driving voltage. The heat was applied to a ferrous substrate mechanically coupled to a cubic 1 cm{sup 3} Lithium Niobate (LiNbO{sub 3}) pyroelectric crystal maintained in a 3–12 mTorr vacuum. The maximum temperature reached was 175 °C in 86 s of heating. The cooling cycle began immediately after heating and was provided by passive radiative cooling. The total combined cycle time was 250 s. x-ray photons were produced and analyzed in both heating and cooling phases. Maximum photon energies of 59 keV and 55 keV were observed during heating and cooling, respectively. Non-contact devices such as this, may find applications in cancer therapy (brachytherapy), non-destructive testing, medical imaging, and physics education fields.

  12. Energy from Waste: Reuse of Compost Heat as a Source of Renewable Energy

    Directory of Open Access Journals (Sweden)

    G. Irvine

    2010-01-01

    Full Text Available An in-vessel tunnel composting facility in Scotland was used to investigate the potential for collection and reuse of compost heat as a source of renewable energy. The amount of energy offered by the compost was calculated and seasonal variations analysed. A heat exchanger was designed in order to collect and transfer the heat. This allowed heated water of 47.3oC to be obtained. The temperature could be further increased to above 60oC by passing it through multiple tunnels in series. Estimated costs for installing and running the system were calculated. In order to analyse these costs alternative solar thermal and ground source heat pump systems were also designed. The levels of supply and economic performance were then compared. A capital cost of £11,662 and operating cost of £1,039 per year were estimated, resulting in a cost of £0.50 per kWh for domestic water and £0.10 per kWh for spatial heat. Using the heat of the compost was found to provide the most reliable level of supply at a similar price to its rivals.

  13. Thermal hydraulic design and decay heat removal of a solid target for a spallation neutron source

    Energy Technology Data Exchange (ETDEWEB)

    Takenaka, N. [Department of Mechanical Engineering, Kobe University, Kobe (Japan)]. E-mail: takenaka@mech.kobe-u.ac.jp; Nio, D. [Hokkaido University, Sapporo (Japan); Kiyanagi, Y. [Hokkaido University, Sapporo (Japan); Mishima, K. [Kyoto University Research Reactor Institute, Kumatori (Japan); Kawai, M. [High Energy Accelerator Research Institute, Tsukuba (Japan); Furusaka, M. [High Energy Accelerator Research Institute, Tsukuba (Japan)

    2005-08-01

    Thermal hydraulic design and thermal stress calculations were conducted for a water-cooled solid target irradiated by a MW-class proton beam for a spallation neutron source. Plate type and rod bundle type targets were examined. The thickness of the plate and the diameter of the rod were determined based on the maximum and the wall surface temperature. The thermal stress distributions were calculated by a finite element method (FEM). The neutronics performance of the target is roughly proportional to its average density. The averaged densities of the designed targets were calculated for tungsten plates, tantalum-clad tungsten plates, tungsten rods sheathed by tantalum and Zircaloy and they were compared with mercury density. It was shown that the averaged density was highest for the tungsten plates and was high for the tantalum cladding tungsten plates, the tungsten rods sheathed by tantalum and Zircaloy in order. They were higher than or equal to that of mercury for the 1-2 MW proton beams. Tungsten target without the cladding or the sheath is not practical due to corrosion by water under irradiation condition. Therefore, the tantalum cladding tungsten plate already made successfully by HIP and the sheathed tungsten rod are the candidate of high performance solid targets. The decay heat of each target was calculated. It was low enough low compared to that of ISIS for the target without tantalum but was about four times as high as that of ISIS when the thickness of the tantalum cladding was 0.5 mm. Heat removal methods of the decay heat with tantalum were examined. It was shown that a special cooling system was required for the target exchange when tantalum was used for the target. It was concluded that the tungsten rod target sheathed with stainless steel or Zircaloy was the most reliable from the safety considerations and had similar neutronics performance to that of mercury.

  14. Thermal hydraulic design and decay heat removal of a solid target for a spallation neutron source

    Science.gov (United States)

    Takenaka, N.; Nio, D.; Kiyanagi, Y.; Mishima, K.; Kawai, M.; Furusaka, M.

    2005-08-01

    Thermal hydraulic design and thermal stress calculations were conducted for a water-cooled solid target irradiated by a MW-class proton beam for a spallation neutron source. Plate type and rod bundle type targets were examined. The thickness of the plate and the diameter of the rod were determined based on the maximum and the wall surface temperature. The thermal stress distributions were calculated by a finite element method (FEM). The neutronics performance of the target is roughly proportional to its average density. The averaged densities of the designed targets were calculated for tungsten plates, tantalum clad tungsten plates, tungsten rods sheathed by tantalum and Zircaloy and they were compared with mercury density. It was shown that the averaged density was highest for the tungsten plates and was high for the tantalum cladding tungsten plates, the tungsten rods sheathed by tantalum and Zircaloy in order. They were higher than or equal to that of mercury for the 1 2 MW proton beams. Tungsten target without the cladding or the sheath is not practical due to corrosion by water under irradiation condition. Therefore, the tantalum cladding tungsten plate already made successfully by HIP and the sheathed tungsten rod are the candidate of high performance solid targets. The decay heat of each target was calculated. It was low enough low compared to that of ISIS for the target without tantalum but was about four times as high as that of ISIS when the thickness of the tantalum cladding was 0.5 mm. Heat removal methods of the decay heat with tantalum were examined. It was shown that a special cooling system was required for the target exchange when tantalum was used for the target. It was concluded that the tungsten rod target sheathed with stainless steel or Zircaloy was the most reliable from the safety considerations and had similar neutronics performance to that of mercury.

  15. Numerical simulation of precessing vortex core dumping by localized nonstationary heat source

    Science.gov (United States)

    Porfiriev, Denis; Gorbunova, Anastasiya; Zavershinsky, Igor; Sugak, Semen; Molevich, Nonna

    2016-10-01

    The precessing vortex core (PVC) is a crucial structure for many technical devices with the heat release. For this purpose, we performed the 3D numerical simulations of PVC in the swirling flow created in the open tube with the paraxial nonstationary heat source. Power of the source was modulated by sinusoidal law. We showed that three turbulence models give the qualitatively similar dependences of PVC frequency and amplitude on the heat-source power. The numerical simulation demonstrated that the obtained PVC is a left-handed co-rotated bending single-vortex structure. For considered values of the swirl and mass flow rate, we obtained that, for wide range of modulation frequencies, the growth of the heat-source power leads to gradual increase in the PVC frequency and slow change in the amplitude of vortex core oscillations. However, for specific modulation frequency, which depends on the tube geometry, dependencies of the PVC frequency and the amplitudes of oscillations have distinct maximum and minimum. Which means that, under specific conditions, flow pattern changes dramatically and precession is almost dumped at the relatively low values of heat power.

  16. Thermal modeling of multi-shape heating sources on n-layer electronic board

    Directory of Open Access Journals (Sweden)

    Monier-Vinard Eric

    2017-01-01

    Full Text Available The present work completes the toolbox of analytical solutions that deal with resolving steady-state temperatures of a multi-layered structure heated by one or many heat sources. The problematic of heating sources having non-rectangular shapes is addressed to enlarge the capability of analytical approaches. Moreover, various heating sources could be located on the external surfaces of the sandwiched layers as well as embedded at interface of its constitutive layers. To demonstrate its relevance, the updated analytical solution has been compared with numerical simulations on the case of a multi-layered electronic board submitted to a set of heating source configurations. The comparison shows a high agreement between analytical and numerical calculations to predict the centroid and average temperatures. The promoted analytical approach establishes a kit of practical expressions, easy to implement, which would be cumulated, using superposition principle, to help electronic designers to early detect component or board temperatures beyond manufacturer limit. The ability to eliminate bad concept candidates with a minimum of set-up, relevant assumptions and low computation time can be easily achieved.

  17. Suppression of cyclotron instability in Electron Cyclotron Resonance ion sources by two-frequency heating

    Energy Technology Data Exchange (ETDEWEB)

    Skalyga, V. [Institute of Applied Physics of Russian Academy of Sciences, 46 Ulyanova st., Nizhny Novgorod (Russian Federation); Lobachevsky State University of Nizhny Novgorod (UNN), 23 Gagarina st., Nizhny Novgorod (Russian Federation); Izotov, I.; Mansfeld, D. [Institute of Applied Physics of Russian Academy of Sciences, 46 Ulyanova st., Nizhny Novgorod (Russian Federation); Kalvas, T.; Koivisto, H.; Komppula, J.; Kronholm, R.; Laulainen, J.; Tarvainen, O. [Department of Physics, University of Jyväskylä, Jyväskylä (Finland)

    2015-08-15

    Multiple frequency heating is one of the most effective techniques to improve the performance of Electron Cyclotron Resonance (ECR) ion sources. The method increases the beam current and average charge state of the extracted ions and enhances the temporal stability of the ion beams. It is demonstrated in this paper that the stabilizing effect of two-frequency heating is connected with the suppression of electron cyclotron instability. Experimental data show that the interaction between the secondary microwave radiation and the hot electron component of ECR ion source plasmas plays a crucial role in mitigation of the instabilities.

  18. Exergy cost analysis of ground source heat pump system%土壤源热泵系统的火用成本分析

    Institute of Scientific and Technical Information of China (English)

    龚光彩; 冯启辉; 苏欢; 徐春雯

    2011-01-01

    在对火用分析与经济学原理研究的基础上,利用火用成本分析方法,建立了土壤源热泵系统的(火用) 成本分析模型.以实际的建筑空调系统为背景,运用所建火用成本分析模型与能量成本分析方法,对土壤源热泵系统与风冷热泵系统进行了对比分析计算,并以空气源热泵为基础对土壤源热泵进行了敏感性分析.对土壤源热泵的实际应用具有指导意义.%Based on the study of the exergy analysis and economics theory, an exergy cost analysis model of ground source heat pump system was established by using the exergy cost analysis method. With the background of an actual building air - conditioning system, the ground source heat pump system and the air source heat pump system were calculated by using exergy cost analysis model and energy cost analysis method. And the sensitivity analysis method was used in the exergy cost of ground source heat pump basing on air source heat pump. The analysis method has guiding significance for practical application of ground source heat pump.

  19. Induction heating pure vapor source of high temperature melting point materials on electron cyclotron resonance ion source.

    Science.gov (United States)

    Kutsumi, Osamu; Kato, Yushi; Matsui, Yuuki; Kitagawa, Atsushi; Muramatsu, Masayuki; Uchida, Takashi; Yoshida, Yoshikazu; Sato, Fuminobu; Iida, Toshiyuki

    2010-02-01

    Multicharged ions that are needed are produced from solid pure material with high melting point in an electron cyclotron resonance ion source. We develop an evaporator by using induction heating (IH) with multilayer induction coil, which is made from bare molybdenum or tungsten wire without water cooling and surrounding the pure vaporized material. We optimize the shapes of induction coil and vaporized materials and operation of rf power supply. We conduct experiment to investigate the reproducibility and stability in the operation and heating efficiency. IH evaporator produces pure material vapor because materials directly heated by eddy currents have no contact with insulated materials, which are usually impurity gas sources. The power and the frequency of the induction currents range from 100 to 900 W and from 48 to 23 kHz, respectively. The working pressure is about 10(-4)-10(-3) Pa. We measure the temperature of the vaporized materials with different shapes, and compare them with the result of modeling. We estimate the efficiency of the IH vapor source. We are aiming at the evaporator's higher melting point material than that of iron.

  20. Hydrothermal-flow regime and magmatic heat source of the Cerro Prieto geothermal system, Baja California, Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Elders, W.A.; Bird, D.K.; Williams, A.E.; Schiffman, P.

    1982-01-01

    This detailed three-dimensional model of the natural flow regime of the Cerro Prieto geothermal field, before steam production began, is based on patterns of hydrothermal mineral zones and light stable isotopic ratios observed in rock samples from more than fifty deep wells, together with temperature gradients, wireline logs and other data. At the level so far penetrated by drilling, this hydrothermal system was heated by a thermal plume of water close to boiling, inclined at 45/sup 0/, rising from the northeast and discharging to the west. To the east a zone of cold water recharge overlies the inclined thermal plume. Fission track annealing studies shows that the reservoir reached 170/sup 0/C only 10/sup 4/ years ago. Oxygen isotope exchange data indicate that a 12 km/sup 3/ volume of rock subsequently reacted with three times its volume of water hotter than 200/sup 0/C. Averaged over the duration of the heating event this would require a flow velocity of about 6 m/year through the pores of a typical cross section of the reservoir having an average porosity of 10%. Although this is an extensional tectonic environment of leaky transform faulting in which repeated intrusions of basalt magma are likely, for simplicity of computation possible heat sources were modelled as simple two dimensional basalt intrusions of various sizes, shapes and locations. We have calculated a series of two-dimensional convective heat transfer models, with different heat sources and permeability distributions. The models which produce the best fit for the temperature distributions observed in the field today have in common a heat source which is a funnel-shaped basalt intrusion, 4 km wide at the top, emplaced at a depth of 5 km to 6 km about 40,000 to 50,000 years ago.

  1. THE NATURAL CONVECTION OF AQUIFERS WITH CONSTANT HEAT SOURCES AND ITS INFLUENCE ON TEMPERATURE FIELDS

    Institute of Scientific and Technical Information of China (English)

    LIU Guo-qing; ZHOU Zhi-fang

    2012-01-01

    By combining sand tank tests with numerical simulations,this paper studies the temperature fields around constant heat sources to reveal the mechanism of the natural convection and its influence on the temperature fields in the process of energy storage.Using the “24-channel temperature auto acquisition system” developed by our research group in the tests,the temperatures are recorded at measuring points within the research area in the tests,the revised Brinkman equation and a transfer-convection balance model are used for solving the aquifer water-thermal coupling problems,and through comparison of the test results with the calculation results,it is discovered that the influence ranges and the variations of the two temperature fields are consistent,which validates the mathematical model.On the basis of this,we also study the influences of the heat source positions and the boundary conditions on the temperature fields,and the results show that,under the natural convection,the heat source positions may influence the distribution of the temperature fields,thus affect the energy storage.For the same energy storage layer,the temperature field for the top energy storage is characterized by a smaller heat influence range and a relatively concentrated temperature distribution.However,when the heat source is at the bottom,the range of a temperature field,and the temperature is relatively dispersed,which is not favorable to heat recycle,with the same heat sourcc position,the boundary conditions determine the size of the critical Rayleigh number,and thus have an influence on the occurrence and the strength of the natural convection,and accordingly,on the temperature fields.

  2. Sustainable renewable energy seawater desalination using combined-cycle solar and geothermal heat sources

    KAUST Repository

    Missimer, Thomas M.

    2013-01-01

    Key goals in the improvement of desalination technology are to reduce overall energy consumption, make the process "greener," and reduce the cost of the delivered water. Adsorption desalination (AD) is a promising new technology that has great potential to reduce the need for conventional power, to use solely renewable energy sources, and to reduce the overall cost of water treatment. This technology can desalt seawater or water of even higher salinity using waste heat, solar heat, or geothermal heat. An AD system can operate effectively at temperatures ranging from 55 to 80 °C with perhaps an optimal temperature of 80 °C. The generally low temperature requirement for the feedwater allows the system to operate quite efficiently using an alternative energy source, such as solar power. Solar power, particularly in warm dry regions, can generate a consistent water temperature of about 90 °C. Although this temperature is more than adequate to run the system, solar energy collection only can occur during daylight hours, thereby necessitating the use of heat storage during nighttime or very cloudy days. With increasing capacity, the need for extensive thermal storage may be problematic and could add substantial cost to the development of an AD system. However, in many parts of the world, there are subsurface geothermal energy sources that have not been extensively used. Combining a low to moderate geothermal energy recovery system to an AD system would provide a solution to the thermal storage issue. However, geothermal energy development from particularly Hot Dry Rock is limited by the magnitude of the heat flow required for the process and the thermal conductivity of the rock material forming the heat reservoir. Combining solar and geothermal energy using an alternating 12-h cycle would reduce the probability of depleting the heat source within the geothermal reservoir and provide the most effective use of renewable energy. © 2013 Desalination Publications.

  3. Mixed Convection Flow of Casson Nanofluid over a Stretching Sheet with Convectively Heated Chemical Reaction and Heat Source/Sink

    Directory of Open Access Journals (Sweden)

    T. Hayat

    2015-01-01

    Full Text Available The present study addresses the mixed convection flow of non-Newtonian nanofluid over a stretching surface in presence of thermal radiation, heat source/sink and first order chemical reaction. Casson fluid model is adopted in the present study. Magnetic field contribution is incorporated in the momentum equation whereas the aspects of nanoparticles are considered in the energy and concentration equations. Convective boundary conditions for both heat and mass transfer are utilized. Similarity transformations are employed to reduce the partial differential equations into ordinary differential equations. Series solutions of the resulting problem are obtained. Impacts of all the physical parameters on the velocity, temperature and concentration fields are analyzed graphically. Numerical values of different involved parameters for local skin friction coefficient, local Nusselt and Sherwood numbers are obtained and discussed.

  4. Observer-based monitoring of heat exchangers.

    Science.gov (United States)

    Astorga-Zaragoza, Carlos-Manuel; Alvarado-Martínez, Víctor-Manuel; Zavala-Río, Arturo; Méndez-Ocaña, Rafael-Maxim; Guerrero-Ramírez, Gerardo-Vicente

    2008-01-01

    The goal of this work is to provide a method for monitoring performance degradation in counter-flow double-pipe heat exchangers. The overall heat transfer coefficient is estimated by an adaptive observer and monitored in order to infer when the heat exchanger needs preventive or corrective maintenance. A simplified mathematical model is used to synthesize the adaptive observer and a more complex model is used for simulation. The reliability of the proposed method was demonstrated via numerical simulations and laboratory experiments with a bench-scale pilot plant.

  5. Internal heating of lithium-ion batteries using alternating current based on the heat generation model in frequency domain

    Science.gov (United States)

    Zhang, Jianbo; Ge, Hao; Li, Zhe; Ding, Zhanming

    2015-01-01

    This study develops a method to internally preheat lithium-ion batteries at low temperatures with sinusoidal alternating current (AC). A heat generation rate model in frequency domain is developed based on the equivalent electrical circuit. Using this model as the source term, a lumped energy conservation model is adopted to predict the temperature rise. These models are validated against the experimental results of preheating an 18650 cell at different thermal insulation conditions. The effects of current amplitude and frequency on the heating rate are illustrated with a series of simulated contours of heating time. These contours indicate that the heating rate increases with higher amplitude, lower frequency and better thermal insulation. The cell subjected to an alternating current with an amplitude of 7 A (2.25 C) and a frequency of 1 Hz, under a calibrated heat transfer coefficient of 15.9 W m-2 K-1, can be heated from -20 °C to 5 °C within 15 min and the temperature distribution remains essentially uniform. No capacity loss is found after repeated AC preheating tests, indicating this method incurs little damage to the battery health. These models are computationally-efficient and can be used in real time to control the preheating devices in electric vehicles.

  6. Sources and potential application of waste heat utilization at a gas processing facility

    Science.gov (United States)

    Alshehhi, Alyas Ali

    Waste heat recovery (WHR) has the potential to significantly improve the efficiency of oil and gas plants, chemical and other processing facilities, and reduce their environmental impact. In this Thesis a comprehensive energy audit at Abu Dhabi Gas Industries Ltd. (GASCO) ASAB gas processing facilities is undertaken to identify sources of waste heat and evaluate their potential for on-site recovery. Two plants are considered, namely ASAB0 and ASAB1. Waste heat evaluation criteria include waste heat grade (i.e., temperature), rate, accessibility (i.e., proximity) to potential on-site waste heat recovery applications, and potential impact of recovery on installation performance and safety. The operating parameters of key waste heat source producing equipment are compiled, as well as characteristics of the waste heat streams. In addition, potential waste heat recovery applications and strategies are proposed, focusing on utilities, i.e., enhancement of process cooling/heating, electrical/mechanical power generation, and steam production. The sources of waste heat identified at ASAB facilities consist of gas turbine and gas generator exhaust gases, flared gases, excess propane cooling capacity, excess process steam, process gas air-cooler heat dissipation, furnace exhaust gases and steam turbine outlet steam. Of the above waste heat sources, exhaust gases from five gas turbines and one gas generator at ASAB0 plant, as well as from four gas turbines at ASAB1 plant, were found to meet the rate (i.e., > 1 MW), grade (i.e., > 180°C), accessibility (i.e., absorption refrigeration unit for gas turbine inlet air cooling, which would result in additional electric or mechanical power generation, and pre-cooling of process gas, which could reduce the need for or eliminate air coolers, as well as reduce propane chiller load, and ii) serve for heating of lean gas, which would reduce furnace load. At ASAB1, it is proposed that exhaust gases from all four gas turbines be used to

  7. Effect of the inter-block spacing on the thermal performance of a PCM based heat sink

    Energy Technology Data Exchange (ETDEWEB)

    Faraji, M.; El Qarnia, H. [Cadi Ayyad Univ., Marrakech (Morocco). Faculte des sciences Semlalia, Dept. de physique, Laboratoire de mecanique des fluides et d' energetique; El Khadir, L. [Cadi Ayyad Univ., Marrakech (Morocco). Faculte des sciences Semlalia, Dept. de physique, Laboratoire d' tomatique de l' Environnement et Procedes de Transferts

    2010-07-01

    Advanced electronic devices require efficient thermal control systems. Heat transfer analysis of such systems is challenging because of constraints regarding space limitations, power consumption and noise level. This study considered the problem of melting and natural convection in a rectangular enclosure heated with 3 heat sources with a constant and uniform volumetric heat generation. The heat sources were protruding and mounted on a vertical conducting plate. Conjugate conduction in a plate and heat sources coupled with natural convection and melting process were examined in an effort to determine the effects of the inter-blocks spacing ratio on the thermal performance of the cooling PCM-heat sink. The percentage contribution of substrate heat conduction on the total removed heat from heat sources was also investigated. Correlations were derived for the non- dimensional secured working time and the corresponding melt fraction. In order to investigate the thermal behaviour of the proposed heat sink, a mathematical model was developed based on the mass, momentum and energy conservation equations. The results revealed that for lower inter-blocks spacing, the dimensionless secured working time needed by the chips to reach the critical temperature was maximized. The highest inter-blocks spacing ratio provoked a sudden rise in chip temperatures and thus reduced the dimensionless secured working time. It was concluded that this approach can be used in the design of PCM-based cooling systems. 9 refs., 2 tabs., 4 figs.

  8. Chemical characteristics and source apportionment of atmospheric particles during heating period in Harbin, China

    Institute of Scientific and Technical Information of China (English)

    Likun Huang; Guangzhi Wang

    2014-01-01

    Atmospheric particles (total suspended particles (TSPs); particulate matter (PM) with particle size below 10 μm,PM10; particulate matter with particle size below 2.5 μm,PM2.5)were collected and analyzed during heating and non-heating periods in Harbin.The sources of PM10 and PM2.5 were identified by the chemical mass balance (CMB) receptor model.Results indicated that PM2.5/TSP was the most prevalent and PM2.5 was the main component of PM10,while the presence of PM10-100 was relatively weak.SC42-and NO3-concentrations were more significant than other ions during the heating period.As compared with the non-heating period,Mn,Ni,Pb,S,Si,Ti,Zn,As,Ba,Cd,Cr,Fe and K were relatively higher during the heating period.In particular,Mn,Ni,S,Si,Ti,Zn and As in PM2.5 were obviously higher during the heating period.Organic carbon (OC) in the heating period was 2-5 times higher than in the non-heating period.Elemental carbon (EC) did not change much.OC/EC ratios were 8-11 during the heating period,which was much higher than in other Chinese cities (OC/EC:4-6).Results from the CMB indicated that 11 pollution sources were identified,of which traffic,coal combustion,secondary sulfate,secondary nitrate,and secondary organic carbon made the greatest contnbution.Before the heating period,dust and petrochemical industry made a larger contribution.In the heating period,coal combustion and secondary sulfate were higher.After the heating period,dust and petrochemical industry were highen Some hazardous components in PM2.5 were higher than in PM10,because PM2.5 has a higher ability to absorb toxic substances.Thus PM2.5 pollution is more significant regarding human health effects in the heating period.

  9. A small-plane heat source method for measuring the thermal conductivities of anisotropic materials

    Science.gov (United States)

    Cheng, Liang; Yue, Kai; Wang, Jun; Zhang, Xinxin

    2017-07-01

    A new small-plane heat source method was proposed in this study to simultaneously measure the in-plane and cross-plane thermal conductivities of anisotropic insulating materials. In this method the size of the heat source element is smaller than the sample size and the boundary condition is thermal insulation due to no heat flux at the edge of the sample during the experiment. A three-dimensional model in a rectangular coordinate system was established to exactly describe the heat transfer process of the measurement system. Using the Laplace transform, variable separation, and Laplace inverse transform methods, the analytical solution of the temperature rise of the sample was derived. The temperature rises calculated by the analytical solution agree well with the results of numerical calculation. The result of the sensitivity analysis shows that the sensitivity coefficients of the estimated thermal conductivities are high and uncorrelated to each other. At room temperature and in a high-temperature environment, experimental measurements of anisotropic silica aerogel were carried out using the traditional one-dimensional plane heat source method and the proposed method, respectively. The results demonstrate that the measurement method developed in this study is effective and feasible for simultaneously obtaining the in-plane and cross-plane thermal conductivities of the anisotropic materials.

  10. Model of the heat source of the Cerro Prieto magma-hydrothermal system, Baja California, Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Elders, W.A.; Bird, D.K.; Williams, A.E.; Schiffman, P.; Cox, B.

    1982-08-10

    Earlier studies at Cerro Prieto by UCR have led to the development of a qualitative model for field flow in the geothermal system before it was drilled and perturbed by production. Current efforts are directed towards numerical modelling of heat and mass transfer in the system in this undisturbed state. A two-dimensional model assumes that the heat sources were a single basalt/gabbro intrusion which provided heat to the system as it cooled. After compiling various information on the physical properties of the reservoir, the enthalpy contained in two 1cm thick section across the reservoir orthogonal to each other was calculated. Next various shapes, sizes and depths for the intrusion as initial conditions and boundary conditions for the calculation of heat transfer were considered. A family of numerical models which so far gives the best matches to the conditions observed in the field today have in common a funnel-shaped intrusion with a top 4km wide emplaced at a depth of 5km some 30,000 to 50,000 years ago, providing heat to the geothermal system. Numerical modelling is still in progress. Although none of the models so far computed may be a perfect match for the thermal history of the reservoir, they all indicate that the intrusive heat source is young, close and large.

  11. Study on a groundwater source heat pump cooling system in solar greenhouse

    Energy Technology Data Exchange (ETDEWEB)

    Chai, Lilong; Ma, Chengwei [China Agricultural Univ., Beijing (China). Coll. of Water Conservancy and Civil Engineering. Dept. of Agricultural Structure and Bio-environmental Engineering], E-mail: macwbs@cau.edu.cn

    2008-07-01

    This study aims at exploiting the potential of ground source heat pump (GSHP) technology in cooling agricultural greenhouse, and advocating the use of renewable and clean energy in agriculture. GSHP has the multi-function of heating, cooling and dehumidifying, which is one of the fastest growing technologies of renewable energy air conditioning in recent years. The authors carried out experiment on the ground source heat pump system in cooling greenhouse in Beijing region during the summertime of 2007, and conducted analysis on the energy efficiency of the system by using coefficient of performance (COP). According to the data collected during Aug.13-18th, 2007, the coefficient of performance of GSHP system (COP{sub sys}) has reached 3.15 on average during the test. (author)

  12. Mathematical Modeling of Magneto Pulsatile Blood Flow Through a Porous Medium with a Heat Source

    Directory of Open Access Journals (Sweden)

    Sharma B.K

    2015-05-01

    Full Text Available In the present study a mathematical model for the hydro-magnetic non-Newtonian blood flow in the non-Darcy porous medium with a heat source and Joule effect is proposed. A uniform magnetic field acts perpendicular to the porous surface. The governing non-linear partial differential equations have been solved numerically by applying the explicit finite difference Method (FDM. The effects of various parameters such as the Reynolds number, hydro-magnetic parameter, Forchheimer parameter, Darcian parameter, Prandtl number, Eckert number, heat source parameter, Schmidt number on the velocity, temperature and concentration have been examined with the help of graphs. The present study finds its applications in surgical operations, industrial material processing and various heat transfer operations.

  13. Study on a groundwater source heat pump cooling system in solar greenhouse

    Energy Technology Data Exchange (ETDEWEB)

    Chai, Lilong; Ma, Chengwei [China Agricultural Univ., Beijing (China). Coll. of Water Conservancy and Civil Engineering. Dept. of Agricultural Structure and Bio-environmental Engineering], E-mail: macwbs@cau.edu.cn

    2008-07-01

    This study aims at exploiting the potential of ground source heat pump (GSHP) technology in cooling agricultural greenhouse, and advocating the use of renewable and clean energy in agriculture. GSHP has the multi-function of heating, cooling and dehumidifying, which is one of the fastest growing technologies of renewable energy air conditioning in recent years. The authors carried out experiment on the ground source heat pump system in cooling greenhouse in Beijing region during the summertime of 2007, and conducted analysis on the energy efficiency of the system by using coefficient of performance (COP). According to the data collected during Aug.13-18th, 2007, the coefficient of performance of GSHP system (COP{sub sys}) has reached 3.15 on average during the test. (author)

  14. General-purpose heat source safety verification test series: SVT-7 through SVT-10

    Science.gov (United States)

    George, T. G.; Pavone, D.

    1985-09-01

    The General-Purpose Heat Source (GPHS) is a modular component of the radioisotope thermoelectric generator that will supply power for the Galileo and Ulysses (formerly ISPM) space missions. The GPHS provides power by transmitting the heat of (238)PuO2 (ALPHA)-decay to an array of thermoelectric elements. Because the possibility of an orbital abort always exists, the heat source was designed and constructed to minimize plutonia release in any accident environment. The Safety Verification Test (SVT) series was formulated to evaluate the effectiveness of GPHS plutonia containment after atmospheric reentry and Earth impact. The first report (covering SVT-1 through SVT-6) described the results of flat and side-on module impacts. This report describes module impacts at angles of 15(0) and 30(0).

  15. General-purpose heat source safety verification test series: SVT-11 through SVT-13

    Science.gov (United States)

    George, T. G.; Pavone, D.

    1986-05-01

    The General-Purpose Heat Source (GPHS) is a modular component of the radioisotope thermoelectric generator that will provide power for the Galileo and Ulysses (formerly ISPM) space missions. The GPHS provides power by transmitting the heat of Pu -decay to an array of thermoelectric elements. Because the possibility of an orbital abort always exists, the heat source was designed and constructed to minimize plutonia release in any accident environment. The Safety Verification Test (SVT) series was formulated to evaluate the effectiveness of GPHS plutonia containment after atmospheric reentry and Earth impact. The first two reports (covering SVT-1 through SVT-10) described the results of flat, side-on, and angular module impacts against steel targets at 54 m/s. This report describes flat-on module impacts against concrete and granite targets, at velocities equivalent to or higher than previous SVTs.

  16. Calculation of temperature field in gas flow with internal heat source

    Directory of Open Access Journals (Sweden)

    Gerasimov Alexander V.

    2015-01-01

    Full Text Available Gas flow sequentially moving through three zones (input z1 of a cylindrical channel was considered. Analytical solutions taking into account the influence of heat source limitation in the axial direction and intensity of air flow in this direction on thermal balance were obtained.

  17. Alternative energy sources for the heating and cooling of a building

    CSIR Research Space (South Africa)

    Strydom, JFS

    1979-11-27

    Full Text Available The objective of two of the studies was to choose the most economical source of heating energy, taking cognizance of the building owner’s particular circumstances; in both cases a suitable alternative to light petroleum oil, which had been used...

  18. Barriers for district heating as a source of flexibility for the electricity system

    DEFF Research Database (Denmark)

    Skytte, Klaus; Olsen, Ole Jess; Soysal, Emilie Rosenlund

    2017-01-01

    The Scandinavian countries Denmark, Norway and Sweden currently deploy large amounts of variable renewable energy (VRE) sources, especially wind power. This calls for additional flexibility in the power market. The right coupling to the underlying national and local district heating (DH) markets...

  19. Plasma diagnostics approach to welding heat source/molten pool interaction

    Energy Technology Data Exchange (ETDEWEB)

    Key, J.F.; McIlwain, M.E.; Isaacson, L.

    1980-01-01

    Plasma diagnostic techniques show that weld fusion zone profile and loss of metal vapors from the molten pool are strongly dependent on both the intensity and distribution of the heat source. These plasma properties, are functions of cathode vertex angle and thermal conductivity of the shielding gas, especially near the anode.

  20. Integration of available regenerative energy sources in community networks for both electricity and heating

    Energy Technology Data Exchange (ETDEWEB)

    Alcalde Melo, Henrique

    2013-03-06

    In the last years, energy prices for German households have been increasing constantly. Some reasons for that include: the dependency of Germany on external fossil fuels to supply its energy demand, the decision to invest in renewable energy generation and to shut down all its nuclear power plants. Nowadays households are already able to generate energy on-site, however the generation potential depends on climatic conditions as well as the specific location and the type of the building. The aim of this work is to evaluate whether a community of new efficient single-family houses can generate enough energy on-site to supply its electricity and heating demand over the year based on renewable energy sources and with the support of energy storage systems, including electric vehicles. The theoretical community is situated in the city of Cottbus, Germany. For this community, an electricity load profile was designed based on the use of common devices and separated in controllable and uncontrollable loads. Electricity is generated on-site through photovoltaic panels and small wind turbines, and the electricity generation potential is evaluated based on the community's available space, which is rather limited, and the actual regulations in the State of Brandenburg. A comparison of the available technologies to supply the heating demand as well as to store energy in the household sector is presented and discussed. It is assumed that each household has an electric vehicle that can be charged and also discharged in the community as an extra energy storage system. A software simulation system was designed with which an energy balance analysis is carried out based on hourly values of supply and demand. Under the assumptions taken for this study, the results of the simulation show that the community is able to generate more energy than consumed throughout a year, however in a few occasions there is not enough energy available to supply the community's energy demand

  1. Boiling heat transfer in a hydrofoil-based micro pin fin heat sink

    Energy Technology Data Exchange (ETDEWEB)

    Kosar, Ali; Peles, Yoav [Department of Mechanical, Aerospace and Nuclear Engineering, Rensselaer Polytechnic Institute, Troy, NY 12180 (United States)

    2007-03-15

    Flow boiling of R-123 in a hydrofoil-based micro pin fin heat sink was investigated. Average two-phase heat transfer coefficients were obtained over effective heat fluxes ranging from 19 to 312 W/cm{sup 2} and mass fluxes from 976 to 2349 kg/m{sup 2} s. The paper presents a flow map, which divides the data into three flow pattern regions: bubbly, wavy intermittent and spray-annular flows. Heat transfer coefficient trends and flow morphologies were used to infer boiling heat transfer mechanisms. Existing conventional scale correlations for circular tubes resulted in large scatter and were not able to predict the heat transfer coefficients accurately. (author)

  2. The Heated Halo for Space-Based Blackbody Emissivity Measurement

    Science.gov (United States)

    Gero, P.; Taylor, J. K.; Best, F. A.; Revercomb, H. E.; Garcia, R. K.; Adler, D. P.; Ciganovich, N. N.; Knuteson, R. O.; Tobin, D. C.

    2012-12-01

    The accuracy of radiance measurements with space-based infrared spectrometers is contingent on the quality of the calibration subsystem, as well as knowledge of its uncertainty. Upcoming climate benchmark missions call for measurement uncertainties better than 0.1 K (k=3) in radiance temperature for the detection of spectral climate signatures. Blackbody cavities impart the most accurate calibration for spaceborne infrared sensors, provided that their temperature and emissivity is traceably determined on-orbit. The On-Orbit Absolute Radiance Standard (OARS) has been developed at the University of Wisconsin and has undergone further refinement under the NASA Instrument Incubator Program (IIP) to meet the stringent requirements of the next generation of infrared remote sensing instruments. It provides on-orbit determination of both traceable temperature and emissivity for calibration blackbodies. The Heated Halo is the component of the OARS that provides a robust and compact method to measure the spectral emissivity of a blackbody in situ. A carefully baffled thermal source is placed in front of a blackbody in an infrared spectrometer system, and the combined radiance of the blackbody and Heated Halo reflection is observed. Knowledge of key temperatures and the viewing geometry allow the blackbody cavity spectral emissivity to be calculated. We present the results from the Heated Halo methodology implemented with a new Absolute Radiance Interferometer (ARI), which is a prototype space-based infrared spectrometer designed for climate benchmarking. We show the evolution of the technical readiness level of this technology and we compare our findings to models and other experimental methods of emissivity determination.

  3. Impacts of New EU and Czech Environmental Legislation on Heat and Electricity Prices of Combined Heat and Power Sources in the Czech Republic

    Directory of Open Access Journals (Sweden)

    J. Vecka

    2011-01-01

    Full Text Available In my economic model I calculate the impact of the new EU ETS Directive, the Industrial Emissions Directive and the new air protection law on future heat and electricity prices for combined heat and power sources. I discover that there will be a significant increase in heat and electricity prices, especially because of the implementation of new so-called benchmark tools for allocating allowances. The main problem of large heat producers in this respect is loss of competitiveness on the heat market due to emerging stricter environmental legislation, which is not applied to competitors on the heat market (smaller heat sources. There is also lack of clarity about the modalities for allocating free allowances, and about the future development of the whole carbon market (the future European allowance price.

  4. Chemical reaction and heat source effects on MHD oscillatory flow in an irregular channel

    Directory of Open Access Journals (Sweden)

    P.V. Satya Narayana

    2016-12-01

    Full Text Available This paper investigates the effect of heat and mass transfer on MHD oscillatory flow in an asymmetric wavy channel with chemical reaction and heat source. The unsteadiness in the flow is due to an oscillatory pressure gradient across the ends of the channel. A magnetic field of uniform strength is applied in the direction perpendicular to the channel. However, the induced magnetic field is neglected due to the assumption of small magnetic Reynolds number. The temperature difference of the channel is also assumed high enough to induce heat transfer due to radiation. The governing equations are solved analytically by regular perturbation method. The analytical results are evaluated numerically and then are presented graphically to discuss the effects of different parameters entering into the problem. It is observed that the heat transport of a system is more increased in oscillatory flow than in ordinary conduction.

  5. Optimization and thermoeconomics research of a large reclaimed water source heat pump system.

    Science.gov (United States)

    Zhang, Zi-ping; Du, Fang-hui

    2013-01-01

    This work describes a large reclaimed water source heat pump system (RWSHPS) and elaborates on the composition of the system and its design principles. According to the characteristics of the reclaimed water and taking into account the initial investment, the project is divided into two stages: the first stage adopts distributed heat pump heating system and the second adopts the combination of centralized and decentralized systems. We analyze the heating capacity of the RWSHPS, when the phase II project is completed, the system can provide hydronic heating water with the supply and return water temperature of 55°C/15°C and meet the hydronic heating demand of 8 million square meters of residential buildings. We make a thermal economics analysis by using Thermal Economics theory on RWSHPS and gas boiler system, it is known that the RWSHPS has more advantages, compared with the gas boiler heating system; both its thermal efficiency and economic efficiency are relatively high. It provides a reference for future applications of the RWSHPS.

  6. Sensitivity analysis on the performances of a closed-loop Ground Source Heat Pump

    Science.gov (United States)

    Casasso, Alessandro; Sethi, Rajandrea

    2014-05-01

    Ground Source Heat Pumps (GSHP) permit to achieve a significant reduction of greenhouse gas emissions, and the margins for economic saving of this technology are strongly correlated to the long-term sustainability of the exploitation of the heat stored in the soil. The operation of a GSHP over its lifetime should be therefore modelled considering realistic conditions, and a thorough characterization of the physical properties of the soil is essential to avoid large errors of prediction. In this work, a BHE modelling procedure with the finite-element code FEFLOW is presented. Starting from the governing equations of the heat transport in the soil around a GSHP and inside the BHE, the most important parameters are individuated and the adopted program settings are explained. A sensitivity analysis is then carried on both the design parameters of the heat exchanger, in order to understand the margins of improvement of a careful design and installation, and the physical properties of the soil, with the aim of quantifying the uncertainty induced by their variability. The relative importance of each parameter is therefore assessed by comparing the statistical distributions of the fluid temperatures and estimating the energy consumption of the heat pump, and practical conclusions are from these results about the site characterization, the design and the installation of a BHE. References Casasso A., Sethi R., 2014 Efficiency of closed loop geothermal heat pumps: A sensitivity analysis, Renewable Energy 62 (2014), pp. 737-746 Chiasson A.C., Rees S.J., Spitler J.D., 2000, A preliminary assessment of the effects of groundwater flow on closed-loop ground-source heat pump systems, ASHRAE Transactions 106 (2000), pp. 380-393 Delaleux F., Py X., Olives R., Dominguez A., 2012, Enhancement of geothermal borehole heat exchangers performances by improvement of bentonite grouts conductivity, Applied Thermal Engineering 33-34, pp. 92-99 Diao N., Li Q., Fang Z., 2004, Heat transfer in

  7. Shallow Groundwater Temperatures and the Urban Heat Island Effect: the First U.K City-wide Geothermal Map to Support Development of Ground Source Heating Systems Strategy

    Science.gov (United States)

    Patton, Ashley M.; Farr, Gareth J.; Boon, David P.; James, David R.; Williams, Bernard; Newell, Andrew J.

    2015-04-01

    The first UK city-wide heat map is described based on measurements of groundwater from a shallow superficial aquifer in the coastal city of Cardiff, Wales, UK. The UK Government has a target of reducing greenhouse gas emissions by 80% by 2050 (Climate Change Act 2008) and low carbon technologies are key to achieving this. To support the use of ground source heating we characterised the shallow heat potential of an urban aquifer to produce a baseline dataset which is intended to be used as a tool to inform developers and to underpin planning and regulation. We exploited an existing network of 168 groundwater monitoring boreholes across the city, recording the water temperature in each borehole at 1m depth intervals up to a depth of 20m. We recorded groundwater temperatures during the coldest part of 2014, and repeat profiling of the boreholes in different seasons has added a fourth dimension to our results and allowed us to characterise the maximum depth of seasonal temperature fluctuation. The temperature profiles were used to create a 3D model of heat potential within the aquifer using GOCAD® and the average borehole temperatures were contoured using Surfer® 10 to generate a 2D thermal resource map to support future assessment of urban Ground Source Heat Pumps prospectively. The average groundwater temperature in Cardiff was found to be above the average for England and Wales (11.3°C) with 90% of boreholes in excess of this figure by up to 4°C. The subsurface temperature profiles were also found to be higher than forecast by the predicted geothermal gradient for the area. Potential sources for heat include: conduction from buildings, basements and sub-surface infrastructure; insulation effects of the urban area and of the geology, and convection from leaking sewers. Other factors include recharge inhibition by drains, localised confinement and rock-water interaction in specific geology. It is likely to be a combination of multiple factors which we are hoping

  8. Dynamic effects on containment of air-curtain fume hood operated with heat source.

    Science.gov (United States)

    Chen, Jia-Kun; Huang, Rong Fung; Hsin, Pei-Yi

    2012-01-01

    This study focused on the leakage characteristics of the air-curtain fume hood that are subject to the influences of sash movement and walk-by motion while a high temperature heat source was operated in the hood. The flow visualization and trace gas test method were used to investigate the performance of the air-curtain fume hood. An electric heater was placed in the hood to simulate the heat source. The temperature of the heat source installed inside the air-curtain fume hood varied between 180°C and 300°C. Trace gas tests following the dynamic test methods of EN-14175 protocol were employed to measure the spillages of sulfur hexafluoride gas that were released in the hood. When subject to the influence of sash movement at a heat source temperature lower than 260°C, the leakage level was high at the suction velocity V(s) 10 m/sec. When subject to the influence of people walk-by, the leakage level was relatively low at the suction velocity larger than 8 m/sec at sash height H = 50 cm. The height of the sash opening was a crucial parameter for the containment of the air-curtain fume hood. At the sash opening lower than about 25 cm, suction velocity less than or equal to 6 m/sec was enough to make the sulfur hexafluoride leakage less than the threshold value, 0.65 ppm, suggested by the BG Chemie. The air-curtain fume hood presented a great performance to resist the effect of drafts even though there was a high temperature heat source working in the hood.

  9. Identifying (subsurface) anthropogenic heat sources that influence temperature in the drinking water distribution system

    Science.gov (United States)

    Agudelo-Vera, Claudia M.; Blokker, Mirjam; de Kater, Henk; Lafort, Rob

    2017-09-01

    The water temperature in the drinking water distribution system and at customers' taps approaches the surrounding soil temperature at a depth of 1 m. Water temperature is an important determinant of water quality. In the Netherlands drinking water is distributed without additional residual disinfectant and the temperature of drinking water at customers' taps is not allowed to exceed 25 °C. In recent decades, the urban (sub)surface has been getting more occupied by various types of infrastructures, and some of these can be heat sources. Only recently have the anthropogenic sources and their influence on the underground been studied on coarse spatial scales. Little is known about the urban shallow underground heat profile on small spatial scales, of the order of 10 m × 10 m. Routine water quality samples at the tap in urban areas have shown up locations - so-called hotspots - in the city, with relatively high soil temperatures - up to 7 °C warmer - compared to the soil temperatures in the surrounding rural areas. Yet the sources and the locations of these hotspots have not been identified. It is expected that with climate change during a warm summer the soil temperature in the hotspots can be above 25 °C. The objective of this paper is to find a method to identify heat sources and urban characteristics that locally influence the soil temperature. The proposed method combines mapping of urban anthropogenic heat sources, retrospective modelling of the soil temperature, analysis of water temperature measurements at the tap, and extensive soil temperature measurements. This approach provided insight into the typical range of the variation of the urban soil temperature, and it is a first step to identifying areas with potential underground heat stress towards thermal underground management in cities.

  10. A review of solar energy based heat and power generation systems

    DEFF Research Database (Denmark)

    Modi, Anish; Bühler, Fabian; Andreasen, Jesper Graa

    2017-01-01

    The utilization of solar energy based technologies has attracted increased interest in recent times in order to satisfy the various energy demands of our society. This paper presents a thorough review of the open literature on solar energy based heat and power plants. In order to limit the scope...... of the review, only fully renewable plants with at least the production of electricity and heat/hot water for end use are considered. These include solar photovoltaic and solar thermal based plants with both concentrating and non-concentrating collectors in both solar-only and solar-hybrid configurations....... The paper also presents a selection of case studies for the evaluation of solar energy based combined heat and power generation possibility in Denmark. The considered technologies for the case studies are (1) solar photovoltaic modules, (2) solar flat plate collectors, (3) a ground source heat pump, (4...

  11. Improvement of efficiency and temperature control of induction heating vapor source on electron cyclotron resonance ion source.

    Science.gov (United States)

    Takenaka, T; Kiriyama, R; Muramatsu, M; Kitagawa, A; Uchida, T; Kurisu, Y; Nozaki, D; Yano, K; Yoshida, Y; Sato, F; Kato, Y; Iida, T

    2012-02-01

    An electron cyclotron resonance ion source (ECRIS) is used to generate multicharged ions for many kinds of the fields. We have developed an evaporator by using induction heating method that can generate pure vapor from solid state materials in ECRIS. We develop the new matching and protecting circuit by which we can precisely control the temperature of the induction heating evaporator. We can control the temperature within ±15 °C around 1400 °C under the operation pressure about 10(-4) Pa. We are able to use this evaporator for experiment of synthesizing process to need pure vapor under enough low pressure, e.g., experiment of generation of endohedral Fe-fullerene at the ECRIS.

  12. Swedish Homeowners' Attitude towards Water-Based Heating Systems

    Energy Technology Data Exchange (ETDEWEB)

    Gustavsson, L.; Mahapatra, K. (Mid Sweden Univ., Ecotechnology, SE-831 25 Oestersund (Sweden)). e-mail: leif.gustavsson@miun.se

    2008-10-15

    In 2004 and 2007, we conducted questionnaire surveys of 1,500 randomly selected Swedish homeowners of detached houses to understand their attitude towards adopting an innovative heating system (IHS). The results showed that there was no substantial change in homeowners' attitude towards IHSs. More than 80% of the respondents did not intend to install a new heating system. Economic aspects and functional reliability were the most important factors in the respondents' choice of heating system while environmental factors were of less importance. Installers were the most frequently consulted source of information on heating systems. Respondents perceived the relative advantage of pellet boilers over oil or electricity-based heating systems, but bedrock heat pump system was ranked higher than pellet heating system in every aspect except for investment cost. Pellet heating system has advantages with respect to investment cost. District heating system was considered as most functionally reliable and automatic. Keywords: Heat sector, socio-economic aspects, market implementation

  13. An Experimental Study of Waveguide Coupled Microwave Heating with Conventional Multicusp Negative Ion Source

    CERN Document Server

    Komppula, J; Koivisto, H; Laulainen, J; Tarvainen, O

    2015-01-01

    Negative ion production with conventional multicusp plasma chambers utilizing 2.45 GHz microwave heating is demonstrated. The experimental results were obtained with the multicusp plasma chambers and extraction systems of the RFdriven RADIS ion source and the filament driven arc discharge ion source LIISA. A waveguide microwave coupling system, which is almost similar to the one used with the SILHI ion source, was used. The results demonstrate that at least one third of negative ion beam obtained with inductive RF-coupling (RADIS) or arc discharge (LIISA) can be achieved with 1 kW of 2.45 GHz microwave power in CW mode without any modification of the plasma chamber. The co-extracted electron to H^- ratio and the optimum pressure range were observed to be similar for both heating methods. The behaviour of the plasma implies that the energy transfer from the microwaves to the plasma electrons is mainly an off-resonance process.

  14. An experimental study of waveguide coupled microwave heating with conventional multicusp negative ion sources

    Science.gov (United States)

    Komppula, J.; Kalvas, T.; Koivisto, H.; Laulainen, J.; Tarvainen, O.

    2015-04-01

    Negative ion production with conventional multicusp plasma chambers utilizing 2.45 GHz microwave heating is demonstrated. The experimental results were obtained with the multicusp plasma chambers and extraction systems of the RF-driven RADIS ion source and the filament driven arc discharge ion source LIISA. A waveguide microwave coupling system, which is almost similar to the one used with the SILHI ion source, was used. The results demonstrate that at least one third of negative ion beam obtained with inductive RF-coupling (RADIS) or arc discharge (LIISA) can be achieved with 1 kW of 2.45 GHz microwave power in CW mode without any modification of the plasma chamber. The co-extracted electron to H- ratio and the optimum pressure range were observed to be similar for both heating methods. The behaviour of the plasma implies that the energy transfer from the microwaves to the plasma electrons is mainly an off-resonance process.

  15. Simulations of the L H transition dynamics with different heat and particle sources

    Institute of Scientific and Technical Information of China (English)

    李会东; 王占辉; Jan Weiland; 冯灏; 孙卫国

    2015-01-01

    It is crucial to increase the total stored energy by realizing the transition from a low confinement (L-mode) state to a high confinement (H-mode) state in magnetic confinement fusion. The L–H transition process is simulated by using the predictive transport code based on Weiland’s fl uid model. Based on the equilibrium parameters obtained from equilibrium fitting (EFIT) in the experiment, the electron density ne, electron temperature Te, ion temperatures Ti, ion poloidal Vp, and toroidal momenta Vt are simulated self-consistently. The L–H transition dynamic behaviors with the formation of the transport barriers of ion and electron temperatures, the electron density, and the ion toroidal momenta are analyzed. During the L–H transition, the strong poloidal fl ow shear in the edge transport barrier region is observed. The crashes of the electron and ion temperature pedestals are also observed during the L–H transition. The effects of the heating and particle sources on the L–H transition process are studied systematically, and the critical power threshold of the L–H transition is also found.

  16. Nanomaterial-based x-ray sources

    Science.gov (United States)

    Cole, Matthew T.; Parmee, R. J.; Milne, William I.

    2016-02-01

    Following the recent global excitement and investment in the emerging, and rapidly growing, classes of one and two-dimensional nanomaterials, we here present a perspective on one of the viable applications of such materials: field electron emission based x-ray sources. These devices, which have a notable history in medicine, security, industry and research, to date have almost exclusively incorporated thermionic electron sources. Since the middle of the last century, field emission based cathodes were demonstrated, but it is only recently that they have become practicable. We outline some of the technological achievements of the past two decades, and describe a number of the seminal contributions. We explore the foremost market hurdles hindering their roll-out and broader industrial adoption and summarise the recent progress in miniaturised, pulsed and multi-source devices.

  17. Waste heat recovery from the European Spallation Source cryogenic helium plants - implications for system design

    Science.gov (United States)

    Jurns, John M.; Bäck, Harald; Gierow, Martin

    2014-01-01

    The European Spallation Source (ESS) neutron spallation project currently being designed will be built outside of Lund, Sweden. The ESS design includes three helium cryoplants, providing cryogenic cooling for the proton accelerator superconducting cavities, the target neutron source, and for the ESS instrument suite. In total, the cryoplants consume approximately 7 MW of electrical power, and will produce approximately 36 kW of refrigeration at temperatures ranging from 2-16 K. Most of the power consumed by the cryoplants ends up as waste heat, which must be rejected. One hallmark of the ESS design is the goal to recycle waste heat from ESS to the city of Lund district heating system. The design of the cooling system must optimize the delivery of waste heat from ESS to the district heating system and also assure the efficient operation of ESS systems. This report outlines the cooling scheme for the ESS cryoplants, and examines the effect of the cooling system design on cryoplant design, availability and operation.

  18. IMPACT OF GEOTHERMAL GRADIENT ON GROUND SOURCE HEAT PUMP SYSTEM MODELING

    Directory of Open Access Journals (Sweden)

    Tomislav Kurevija

    2014-07-01

    Full Text Available ndisturbed ground temperature is one of the most crucial thermogeological parameters needed for shallow geothermal resources assessment. Energy considered to be geothermal is energy stored in the ground at depths where solar radiation has no effect. At depth where undisturbed ground temperature occurs there is no influence of seasonal variations in air temperature from surface. Exact temperature value, and depth where it occurs, is functionally dependent on surface climate parameters and thermogeologic properties of ground. After abovementioned depth, increase of ground temperature is solely dependent on geothermal gradient. Accurately determined value of undisturbed ground temperature is beneficial for proper sizing of borehole heat exchangers. On practical example of building which is being heated and cooled with shallow geothermal resource, influences of undisturbed ground temperature and geothermal gradient, on size of borehole heat exchanger are going to be presented. Sizing of borehole heat exchanger was calculated with commercial software Ground Loop Designer (GLD, which uses modified line source and cylinder source solutions of heat conduction in solids.

  19. 基于太阳能光伏光热组件的双热源热泵机组的实验研究%Experimental Research of Dual-source Heat Pump Unit Based on Solar Photovoltaic and Photothermal Component

    Institute of Scientific and Technical Information of China (English)

    陈剑波; 孙坤; 聂琳杰; 陈雷田

    2015-01-01

    本文基于太阳能光伏光热一体化系统,设计出应用太阳能光伏光热及空气源的双热源热泵机组。使热泵与太阳能光伏光热组件结合组成太阳能热泵系统,利用太阳能光伏光热组件( PV/T)内循环水及空气源的能量制取生活热水,同时降低太阳能光伏光热组件内循环水的温度,从而降低太阳能光伏板的温度。通过实验测得机组在水冷蒸发侧进水温度20℃,热水出水温度50℃的额定工况下,制冷量为2.855 kW,制热量为3.594 kW,COP为3.6。机组在水-水工况及水-风工况下运行的节能性研究结果表明,相对于单一空气源热泵,双热源热泵机组在满足家庭用生活热水需求的前提下,利用热泵技术回收太阳能光伏光热的热量制取生活热水节能性显著。%Based on the solar photovoltaic-thermal integrated system, we designed a dual-source, i. e. , solar photovoltaic-thermal and air source, heat pump unit. The unit becomes solar assisted heat pump system when combined with solar photovoltaic thermal unit, which produces domestic hot water by air source and circulating water in the solar photovoltaic solar-thermal components ( PV/T) and reduces circulating water temperature and solar photovoltaic panel temperature. We drew the conclusion by experiment that when the inflow water temperature is 20 ℃ on the evaporation side and the outflow hot water temperature is 50 ℃ under the rated conditions, the unit capacity is 2. 855 kW for refrigeration and 3. 594 kW for heating, and the COP is 3. 6. When the unit operates in the water-water condition and wa-ter-air condition, the experiment result shows the dual-source heat pump unit has remarkable energy-saving compared with single air source heat pump when the photovoltaic-thermal solar heat is used for domestic hot water.

  20. A Peltier-based variable temperature source

    Science.gov (United States)

    Molki, Arman; Roof Baba, Abdul

    2014-11-01

    In this paper we propose a simple and cost-effective variable temperature source based on the Peltier effect using a commercially purchased thermoelectric cooler. The proposed setup can be used to quickly establish relatively accurate dry temperature reference points, which are necessary for many temperature applications such as thermocouple calibration.

  1. Performance and Economic Modeling of Horizontally Drilled Ground-Source Heat Pumps in Select California Climates

    Science.gov (United States)

    Wiryadinata, Steven

    Service life modeling was performed to gage the viability of unitary 3.5 kWt, ground-source terminal heat pumps (GTHP) employing horizontal directionally drilled geothermal heat exchangers (GHX) over air-source terminal heat pumps (PTHP) in hotels and motels and residential apartment building sectors in California's coastal and inland climates. Results suggest the GTHP can reduce hourly peak demand for the utility by 7%-25% compared to PTHP, depending on the climate and building type. The annual energy savings, which range from -1% to 5%, are highly dependent on the GTHP pump energy use relative to the energy savings attributed to the difference in ground and air temperatures (DeltaT). In mild climates with small ?T, the pump energy use may overcome any advantage to utilizing a GHX. The majority of total levelized cost savings - ranging from 0.18/ft2 to 0.3/ft 2 - are due to reduced maintenance and lifetime capital cost normally associated with geothermal heat pump systems. Without these reductions (not validated for the GTHP system studied), the GTHP technology does not appear to offer significant advantages over PTHP in the climate zones studied here. The GTHP levelized cost was most sensitive to variations in installed cost and in some cases, energy use (influenced by climate zone choice), which together highlights the importance of climate selection for installation, and the need for larger market penetration of ground-source systems in order to bring down installed costs as the technology matures.

  2. Model-based control of district heating supply temperature

    Energy Technology Data Exchange (ETDEWEB)

    Saarinen, Linn

    2010-11-15

    A model-based control strategy for the supply temperature to a district heating network was tested during three weeks at Idbaecken's CHP plant. The aim was to increase the electricity efficiency by a lower supply temperature, without risking the delivery reliability of heat to the district heating customers. Simulations and tests showed that at high loads, the mean supply temperature could be reduced by 4 deg C and the electricity production could be increased by 2.5%

  3. Heat transfer optimization of SCO2 porous flow based on Brinkman model

    Directory of Open Access Journals (Sweden)

    Lin David T.W.

    2016-01-01

    Full Text Available The purpose of this study is to obtain the optimal operating condition in order to find the maximum supercritical CO2 heat extraction in the enhanced geothermal system (EGS. In this study, the heat transfer model conjugated with the Brinkman model is used to evaluate the thermal behavior in the reservoir of the EGS. This numerical model is validated by experiment. Optimization is processed based on the Nelder-Mead approach. The optimal operating conditions are proposed with different pressure, porosity. This study will build the optimal platform of heat source of geothermal power plant.

  4. Air Source Heat Pump a Key Role in the Development of Smart Buildings in Future Energy Systems

    DEFF Research Database (Denmark)

    Craciun, Vasile S.; Trifa, Viorel; Bojesen, Carsten

    2012-01-01

    of energy is used for space heating, space cooling, and domestic hot water production which are provided to residential and commercial buildings. Air source heat pumps (ASHP) are widely used conversion technologies all over the world for providing building thermal energy services as: cooling, heating...

  5. 太阳能辅助地源热泵供暖实验研究%Experimental study of a solar assisted ground source heat pump for heating

    Institute of Scientific and Technical Information of China (English)

    赵忠超; 丰威仙; 巩学梅; 米浩君; 成华; 云龙

    2014-01-01

    An experimental study is performed to determine the performance of the solar assisted ground source heat pump(SAGSHP)by using a solar-ground source heat pump hybrid system in the city of Ningbo. The result shows that comparing with the ground source heat pump(GSHP),when the ratio of solar energy to the whole en-ergy is 41. 9% ,the coefficient of performance( COP)of the heat pump and system can improve 15. 1% and 7. 7% respectively. Therefore,the solar assisted ground source heat pump has a significant performance advan-tage according to the experimental result.%选取宁波某公用建筑的太阳能-地源热泵复合系统为实验系统,对太阳能辅助地源热泵( solar assisted ground source heat pump,SAGSHP)供暖进行了实验研究.研究结果表明:与单一的地源热泵(ground source heat pump,GSHP)相比,当太阳能承担41.9%负荷时,热泵机组和整个系统的能效比(coefficient of performance,COP)分别提高了15.1%和7.7%, SAGSHP 供暖运行模式具有明显的性能优势.

  6. MEMS-based IR-sources

    Science.gov (United States)

    Weise, Sebastian; Steinbach, Bastian; Biermann, Steffen

    2016-03-01

    The series JSIR350 sources are MEMS based infrared emitters. These IR sources are characterized by a high radiation output. Thus, they are excellent for NDIR gas analysis and are ideally suited for using with our pyro-electric or thermopile detectors. The MEMS chips used in Micro-Hybrid's infrared emitters consist of nano-amorphous carbon (NAC). The MEMS chips are produced in the USA. All Micro-Hybrid Emitter are designed and specified to operate up to 850°C. The improvements we have made in the source's packaging enable us to provide IR sources with the best performance on the market. This new technology enables us to seal the housings of infrared radiation sources with soldered infrared filters or windows and thus cause the parts to be impenetrable to gases. Micro-Hybrid provide various ways of adapting our MEMS based infrared emitter JSIR350 to customer specifications, like specific burn-in parameters/characteristic, different industrial standard housings, producible with customized cap, reflector or pin-out.

  7. Application analysis of ground source heat pumps in building space conditioning

    Energy Technology Data Exchange (ETDEWEB)

    Qian, Hua; Wang, Yungang

    2013-07-01

    The adoption of geothermal energy in space conditioning of buildings through utilizing ground source heat pump (GSHP, also known as geothermal heat pump) has increased rapidly during the past several decades. However, the impacts of the GSHP utilization on the efficiency of heat pumps and soil temperature distribution remained unclear and needs further investigation. This paper presents a novel model to calculate the soil temperature distribution and the coefficient of performance (COP) of GSHP. Different scenarios were simulated to quantify the impact of different factors on the GSHP performance, including heat balance, daily running mode, and spacing between boreholes. Our results show that GSHP is suitable for buildings with balanced cooling and heating loads. It can keep soil temperature at a relatively constant level for more than 10 years. Long boreholes, additional space between boreholes, intermittent running mode will improve the performance of GSHP, but large initial investment is required. The improper design will make the COP of GSHP even lower than traditional heat pumps. Professional design and maintenance technologies are greatly needed in order to promote this promising technology in the developing world.

  8. Plasma-Based Ion Beam Sources

    Energy Technology Data Exchange (ETDEWEB)

    Loeb, H. W.

    2005-07-01

    Ion beam sources cover a broad spectrum of scientific and technical applications delivering ion currents between less than 1 mA and about 100 A at acceleration voltages between 100 V and 100 kV. The ions are mostly generated by electron collisions in a gas discharge and then extracted from the discharge plasma, focused and post-accelerated by single- or multi-aperture electrode systems. Some important applications require the neutralization of the exhausted beam either by charge exchange or by admixture of electrons. In the first part of the paper, the theory of ionization by electron impact, the energy and carrier balances in the plasma, and the extraction and focusing mechanisms will be outlined. The principles of the preferred gas discharges and of the ion beam sources based on them are discussed; i.e. of the Penning, bombardment, arc, duoplasmatron, radio frequency, and microwave types. In the second part of the paper, the special requirements of the different applications are described together with the related source hardware. One distinguishes: 1. Single-aperture ion sources producing protons, heavy ions, isotope ions, etc. for particle accelerators, ion microprobes, mass spectrometers, isotope separators, etc.; quality determinative quantities are brightness, emittance, energy width, etc. 2. Broad-beam multi-aperture injector sources for fusion machines with positive or negative deuterium ions; very high beam densities, small portions of molecular ions, flat beam profiles with small divergence angles, etc. are required. 3. Broad-beam multi-aperture ion thrusters for space propulsion operated with singly charged xenon ions; high efficiencies, reliable operation, and long lifetimes are most important. Spin-offs are applied in industry for material processing. Referring to these applications, the following sources will be described in some detail: 1. Cold cathode and filament driven sources, capillary arc and plasmatron types, microwave and ECR-sources. 2

  9. Modeling the Heating of Biological Tissue based on the Hyperbolic Heat Transfer Equation

    CERN Document Server

    Tung, M M; Molina, J A Lopez; Rivera, M J; Berjano, E J

    2008-01-01

    In modern surgery, a multitude of minimally intrusive operational techniques are used which are based on the punctual heating of target zones of human tissue via laser or radio-frequency currents. Traditionally, these processes are modeled by the bioheat equation introduced by Pennes, who considers Fourier's theory of heat conduction. We present an alternative and more realistic model established by the hyperbolic equation of heat transfer. To demonstrate some features and advantages of our proposed method, we apply the obtained results to different types of tissue heating with high energy fluxes, in particular radiofrequency heating and pulsed laser treatment of the cornea to correct refractive errors. Hopefully, the results of our approach help to refine surgical interventions in this novel field of medical treatment.

  10. Thermal energy storage in the form of heat or cold with using of the PCM-based accumulation panels

    Directory of Open Access Journals (Sweden)

    Skovajsa Jan

    2016-01-01

    Full Text Available This article describes the usage of thermal energy storage in the form of heat and cold with an adaptation of the special device which is composed of the thermal panels. These panels are based on the phase change materials (PCM for normal inner environment temperature in buildings. The energy for the thermal energy storage is possible to get from built-in electric heating foil or from the tube heat exchanger, which is build in the thermal panels. This technology is able to use renewable energy sources, for example, solar thermal collectors and air-to-water heat pump as a source of heat for heating of the hot water tank. In the cooling mode, there is able to use the heat pump or photovoltaics panels in combination with thermoelectric coolers for cooling.

  11. Agent-based modelling of heating system adoption in Norway

    Energy Technology Data Exchange (ETDEWEB)

    Sopha, Bertha Maya; Kloeckner, Christian A.; Hertwich, Edgar G.

    2010-07-01

    Full text: This paper introduces agent-based modelling as a methodological approach to understand the effect of decision making mechanism on the adoption of heating systems in Norway. The model is used as an experimental/learning tool to design possible interventions, not for prediction. The intended users of the model are therefore policy designers. Primary heating system adoptions of electric heating, heat pump and wood pellet heating were selected. Random topology was chosen to represent social network among households. Agents were households with certain location, number of peers, current adopted heating system, employed decision strategy, and degree of social influence in decision making. The overall framework of decision-making integrated theories from different disciplines; customer behavior theory, behavioral economics, theory of planned behavior, and diffusion of innovation, in order to capture possible decision making processes in households. A mail survey of 270 Norwegian households conducted in 2008 was designed specifically for acquiring data for the simulation. The model represents real geographic area of households and simulates the overall fraction of adopted heating system under study. The model was calibrated with historical data from Statistics Norway (SSB). Interventions with respects to total cost, norms, indoor air quality, reliability, supply security, required work, could be explored using the model. For instance, the model demonstrates that a considerable total cost (investment and operating cost) increase of electric heating and heat pump, rather than a reduction of wood pellet heating's total cost, are required to initiate and speed up wood pellet adoption. (Author)

  12. Effect of working fluids and internal diameters on thermal performance of vertical and horizontal closed-loop pulsating heat pipes with multiple heat sources

    Directory of Open Access Journals (Sweden)

    Kammuang-Lue Niti

    2016-01-01

    Full Text Available Some electrical applications have a number of heat sources. The closed-loop pulsating heat pipe (CLPHP is applied to transfer heat from these devices. Since the CLPHP primarily transfers heat by means of the working fluid’s phase change in a capillary tube, the thermal performance of the CLPHP significantly depends on the working fluid type and the tube’s internal diameter. In order to provide the fundamental information for manufacturers of heat exchangers, this study on the effect of working fluids and internal diameters has been conducted. Three electrical plate heaters were installed on the CLPHP as the heat sources. The experiments were conducted by varying the working fluid to be R123, ethanol, and water, and the internal diameter to be 1.0 mm, 1.5 mm, and 2.0 mm. For each set of the same working fluid and internal diameter, the input heat fluxes of the heat sources were also made to vary within six different patterns. It can be concluded that when the latent heat of evaporation increases - in the case of vertical CLPHP - and when the dynamic viscosity of the liquid increases - in the case of horizontal CLPHP - the thermal performance decreases. Moreover, when the internal diameter increases, the thermal performance increases for both of vertical and horizontal CLPHPs.

  13. Operation of the CAPRICE electron cyclotron resonance ion source applying frequency tuning and double frequency heating.

    Science.gov (United States)

    Maimone, F; Tinschert, K; Celona, L; Lang, R; Mäder, J; Rossbach, J; Spädtke, P

    2012-02-01

    The properties of the electromagnetic waves heating the electrons of the ECR ion sources (ECRIS) plasma affect the features of the extracted ion beams such as the emittance, the shape, and the current, in particular for higher charge states. The electron heating methods such as the frequency tuning effect and the double frequency heating are widely used for enhancing the performances of ECRIS or even for the routine operation during the beam production. In order to better investigate these effects the CAPRICE ECRIS has been operated using these techniques. The ion beam properties for highly charged ions have been measured with beam diagnostic tools. The reason of the observed variations of this performance can be related to the different electromagnetic field patterns, which are changing inside the plasma chamber when the frequency is varying.

  14. Environmental considerations for geothermal energy as a source for district heating

    Energy Technology Data Exchange (ETDEWEB)

    Rafferty, Kevin D.

    1996-01-01

    Geothermal energy currently provides a stable and environmentally attractive heat source for approximately 20 district heating (DH) systems in the United States. The use of this resource eliminates nearly 100% of the conventional fuel consumption (and, hence, the emissions) of the loads served by these systems. As a result, geothermal DH systems can rightfully claim the title of the most fuel-efficient CH systems in operations today. The cost of producing heat from a geothermal resource (including capitalization of the production facility and cost for pumping) amounts to an average of $1.00 per mission Btu (0.0034 $/kWh). The major environmental challenge for geothermal systems is proper management of the producing aquifer. Many systems are moving toward injection of the geothermal fluids to ensure long-term production.

  15. The cryogenic cooling program in high-heat-load optics at the Advanced Photon Source

    Energy Technology Data Exchange (ETDEWEB)

    Rogers, C.S.

    1993-07-01

    This paper describes some of the aspects of the cryogenic optics program at the Advanced Photon Source (APS). A liquid-nitrogen-cooled, high-vacuum, double crystal monochromator is being fabricated at Argonne National Laboratory (ANL). A pumping system capable of delivering a variable flow rate of up to 10 gallons per minute of pressurized liquid nitrogen and removing 5 kilowatts of x-ray power is also being constructed. This specialized pumping system and monochromator will be used to test the viability of cryogenically cooled, high-heat-load synchrotron optics. It has been determined that heat transfer enhancement will be required for optics used with APS insertion devices. An analysis of a porous-matrix-enhanced monochromator crystal is presented. For the particular case investigated, a heat transfer enhancement factor of 5 to 6 was calculated.

  16. ENERGY STAR Certified Non-AHRI Central Air Conditioner Equipment and Air Source Heat Pump

    Science.gov (United States)

    Certified models meet all ENERGY STAR requirements as listed in the Version 5.0 ENERGY STAR Program Requirements for Air Source Heat Pump and Central Air Conditioner Equipment that are effective as of September 15, 2015. A detailed listing of key efficiency criteria are available at http://www.energystar.gov/index.cfm?c=airsrc_heat.pr_crit_as_heat_pumps Listed products have been submitted to EPA by ENERGY STAR partners that do not participate in the AHRI certification program. EPA will continue to update this list with products that are certified by EPA-recognized certification bodies other than AHRI. The majority of ENERGY STAR products, certified by AHRI, can be found on the CEE/AHRI Verified Directory at http://www.ceedirectory.org/

  17. System simulation for an untreated sewage source heat pump (USSHP) in winter

    Science.gov (United States)

    Qin, Na; Hao, Peng Z.

    2017-01-01

    The paper discusses the system characteristics of an untreated sewage source heat pump in winter. In this system, the sewage enters into the evaporator directly. The variable parameters to control the system contain the sewage temperature at evaporator inlet and the water temperature at condenser inlet. It is found that most parameters, except the condensation heat transfer coefficient, change in the form of sine wave the same as the sewage temperature at inlet. The heating load and consumed power are 12.9kW and 3.45kW when the sewage temperature at inlet is 13°C. COP is about 3.75 in the range of the sewage temperature at inlet of 12-13°C.

  18. Investigation of acoustic gravity waves created by anomalous heat sources: experiments and theoretical analysis

    Science.gov (United States)

    Pradipta, R.; Lee, M. C.

    2013-07-01

    We have been investigating high-power radio wave-induced acoustic gravity waves (AGWs) at Gakona, Alaska, using the High-frequency Active Aurora Research Program (HAARP) heating facility (i.e. HF heater) and extensive diagnostic instruments. This work was aimed at performing a controlled study of the space plasma turbulence triggered by the AGWs originating from anomalous heat sources, as observed in our earlier experiments at Arecibo, Puerto Rico (Pradipta 2007 MS Thesis MIT Press, Cambridge, MA). The HF heater operated in continuous wave (CW) O-mode can heat ionospheric plasmas effectively to yield a depleted magnetic flux tube as rising plasma bubbles (Lee et al 1998 Geophys. Res. Lett. 25 579). Two processes are responsible for the depletion of the magnetic flux tube: (i) thermal expansion and (ii) chemical reactions caused by heated ions. The depleted plasmas create large density gradients that can augment spread F processes via generalized Rayleigh-Taylor instabilities (Lee et al 1999 Geophys. Res. Lett. 26 37). It is thus expected that the temperature of neutral particles in the heated ionospheric region can be increased. Such a heat source in the neutral atmosphere may potentially generate AGWs in the form of traveling ionospheric plasma disturbances (TIPDs). We should point out that these TIPDs have features distinctively different from electric and magnetic field (ExB) drifts of HF wave-induced large-scale non-propagating plasma structures. Moreover, it was noted in our recent study of naturally occurring AGW-induced TIDs that only large-scale AGWs can propagate upward to reach higher altitudes. Thus, in our Gakona experiments we select optimum heating schemes for HF wave-induced AGWs that can be distinguished from the naturally occurring ones. The generation and propagation of AGWs are monitored by MUIR (Modular Ultra high-frequency Ionospheric Radar), Digisonde and GPS/low-earth-orbit satellites. Our theoretical and experimental studies have shown that

  19. Cyclotron-based neutron source for BNCT

    Science.gov (United States)

    Mitsumoto, T.; Yajima, S.; Tsutsui, H.; Ogasawara, T.; Fujita, K.; Tanaka, H.; Sakurai, Y.; Maruhashi, A.

    2013-04-01

    Kyoto University Research Reactor Institute (KURRI) and Sumitomo Heavy Industries, Ltd. (SHI) have developed a cyclotron-based neutron source for Boron Neutron Capture Therapy (BNCT). It was installed at KURRI in Osaka prefecture. The neutron source consists of a proton cyclotron named HM-30, a beam transport system and an irradiation & treatment system. In the cyclotron, H- ions are accelerated and extracted as 30 MeV proton beams of 1 mA. The proton beams is transported to the neutron production target made by a beryllium plate. Emitted neutrons are moderated by lead, iron, aluminum and calcium fluoride. The aperture diameter of neutron collimator is in the range from 100 mm to 250 mm. The peak neutron flux in the water phantom is 1.8×109 neutrons/cm2/sec at 20 mm from the surface at 1 mA proton beam. The neutron source have been stably operated for 3 years with 30 kW proton beam. Various pre-clinical tests including animal tests have been done by using the cyclotron-based neutron source with 10B-p-Borono-phenylalanine. Clinical trials of malignant brain tumors will be started in this year.

  20. Cyclotron-based neutron source for BNCT

    Energy Technology Data Exchange (ETDEWEB)

    Mitsumoto, T.; Yajima, S.; Tsutsui, H.; Ogasawara, T.; Fujita, K. [Sumitomo Heavy Industries, Ltd (Japan); Tanaka, H.; Sakurai, Y.; Maruhashi, A. [Kyoto University Research Reactor Institute (Japan)

    2013-04-19

    Kyoto University Research Reactor Institute (KURRI) and Sumitomo Heavy Industries, Ltd. (SHI) have developed a cyclotron-based neutron source for Boron Neutron Capture Therapy (BNCT). It was installed at KURRI in Osaka prefecture. The neutron source consists of a proton cyclotron named HM-30, a beam transport system and an irradiation and treatment system. In the cyclotron, H- ions are accelerated and extracted as 30 MeV proton beams of 1 mA. The proton beams is transported to the neutron production target made by a beryllium plate. Emitted neutrons are moderated by lead, iron, aluminum and calcium fluoride. The aperture diameter of neutron collimator is in the range from 100 mm to 250 mm. The peak neutron flux in the water phantom is 1.8 Multiplication-Sign 109 neutrons/cm{sup 2}/sec at 20 mm from the surface at 1 mA proton beam. The neutron source have been stably operated for 3 years with 30 kW proton beam. Various pre-clinical tests including animal tests have been done by using the cyclotron-based neutron source with {sup 10}B-p-Borono-phenylalanine. Clinical trials of malignant brain tumors will be started in this year.

  1. Heat Source Neutron Emission Rate Reduction Studies - Water Induced HF Liberation

    Science.gov (United States)

    Matonic, John; Brown, John; Foltyn, Liz; Garcia, Lawrence; Hart, Ron; Herman, David; Huling, Jeff; Pansoy-Hjelvik, M. E. Lisa; Sandoval, Fritz; Spengler, Diane

    2004-02-01

    Plutonium-238 oxide (238PuO2) is used in the fabrication of general purpose heat sources (GPHS) or light-weight radioisotope heater units (LWRHUs). The heat sources supply the thermal energy used in radioisotope thermoelectric generators to power spacecraft for deep space missions and to heat critical components in the cold environs of space. Los Alamos National Laboratory has manufactured heat sources for approximately two decades. The aqueous purification of 238PuO2 is required, due to rigorous total Pu-content, actinide and non-actinide metal impurity, and neutron emission rate specifications. The 238PuO2 aqueous purification process is a new capability at Los Alamos National Laboratory as previously, aqueous purified 238PuO2 occurred at other DOE complexes. The Pu-content and actinide and non-actinide metal impurity specifications are met well within specification in the Los Alamos process, though reduction in neutron emission rates have been challenging. High neutron emission rates are typically attributed to fluoride content in the oxide. The alpha decay from 238Pu results in α,n reactions with light elements such as 17O, 18O, and 19F resulting in high neutron emission rates in the purified 238PuO2. Simple 16O-exchange takes care of the high NER due to 17O, and 18O. A new method to reduce the NER due to 19F in the purified 238PuO2 is presented in this paper. The method involves addition of water to purified 238PuO2, followed by heating to remove the water and liberating fluoride as HF.

  2. A Strongly Heated Neutron Star in the Transient Z Source MAXI J0556-332

    Science.gov (United States)

    Homan, Jeroen; Fridriksson, Joel K.; Wijnands, Rudy; Cackett, Edward M.; Degenaar, Nathalie; Linares, Manuel; Lin, Dacheng; Remillard, Ronald A.

    2014-11-01

    We present Chandra, XMM-Newton, and Swift observations of the quiescent neutron star in the transient low-mass X-ray binary MAXI J0556-332. Observations of the source made during outburst (with the Rossi X-ray Timing Explorer) reveal tracks in its X-ray color-color and hardness-intensity diagrams that closely resemble those of the neutron-star Z sources, suggesting that MAXI J0556-332 had near- or super-Eddington luminosities for a large part of its ~16 month outburst. A comparison of these diagrams with those of other Z sources suggests a source distance of 46 ± 15 kpc. Fits to the quiescent spectra of MAXI J0556-332 with a neutron-star atmosphere model (with or without a power-law component) result in distance estimates of 45 ± 3 kpc, for a neutron-star radius of 10 km and a mass of 1.4 M ⊙. The spectra show the effective surface temperature of the neutron star decreasing monotonically over the first ~500 days of quiescence, except for two observations that were likely affected by enhanced low-level accretion. The temperatures we obtain for the fits that include a power law (kT_eff∞ = 184-308 eV) are much higher than those seen for any other neutron star heated by accretion, while the inferred cooling (e-folding) timescale (~200 days) is similar to other sources. Fits without a power law yield higher temperatures (kT_eff∞ = 190-336 eV) and a shorter e-folding time (~160 days). Our results suggest that the heating of the neutron-star crust in MAXI J0556-332 was considerably more efficient than for other systems, possibly indicating additional or more efficient shallow heat sources in its crust.

  3. A strongly heated neutron star in the transient z source MAXI J0556-332

    Energy Technology Data Exchange (ETDEWEB)

    Homan, Jeroen; Remillard, Ronald A. [MIT Kavli Institute for Astrophysics and Space Research, 77 Massachusetts Avenue 37-582D, Cambridge, MA 02139 (United States); Fridriksson, Joel K.; Wijnands, Rudy [Anton Pannekoek Institute for Astronomy, University of Amsterdam, Postbus 94249, 1090 GE Amsterdam (Netherlands); Cackett, Edward M. [Department of Physics and Astronomy, Wayne State University, 666 W. Hancock St., Detroit, MI 48201 (United States); Degenaar, Nathalie [Department of Astronomy, University of Michigan, 500 Church Street, Ann Arbor, MI 48109 (United States); Linares, Manuel [Instituto de Astrofísica de Canarias, c/ Vía Láctea s/n, E-38205 La Laguna, Tenerife (Spain); Lin, Dacheng, E-mail: jeroen@space.mit.edu [Space Science Center, University of New Hampshire, Durham, NH 03824 (United States)

    2014-11-10

    We present Chandra, XMM-Newton, and Swift observations of the quiescent neutron star in the transient low-mass X-ray binary MAXI J0556-332. Observations of the source made during outburst (with the Rossi X-ray Timing Explorer) reveal tracks in its X-ray color-color and hardness-intensity diagrams that closely resemble those of the neutron-star Z sources, suggesting that MAXI J0556-332 had near- or super-Eddington luminosities for a large part of its ∼16 month outburst. A comparison of these diagrams with those of other Z sources suggests a source distance of 46 ± 15 kpc. Fits to the quiescent spectra of MAXI J0556-332 with a neutron-star atmosphere model (with or without a power-law component) result in distance estimates of 45 ± 3 kpc, for a neutron-star radius of 10 km and a mass of 1.4 M {sub ☉}. The spectra show the effective surface temperature of the neutron star decreasing monotonically over the first ∼500 days of quiescence, except for two observations that were likely affected by enhanced low-level accretion. The temperatures we obtain for the fits that include a power law (kT{sub eff}{sup ∞} = 184-308 eV) are much higher than those seen for any other neutron star heated by accretion, while the inferred cooling (e-folding) timescale (∼200 days) is similar to other sources. Fits without a power law yield higher temperatures (kT{sub eff}{sup ∞} = 190-336 eV) and a shorter e-folding time (∼160 days). Our results suggest that the heating of the neutron-star crust in MAXI J0556-332 was considerably more efficient than for other systems, possibly indicating additional or more efficient shallow heat sources in its crust.

  4. Performance tests of air source heat pumps under frosting conditions. Quality of results

    Science.gov (United States)

    Fahlen, P.

    This report focuses on the analysis of uncertainties in research regarding air-source heat pumps. The principles recommended by the Western European Calibration Conference (WECC) are applied and the generated information is condensed in the form of uncertainty budgets. The ensuring discussion, and the Measurement Assurance Program that was applied during the research work are also relevant to general testing of cooling coils, e.g. for air source heat pumps. The general conclusion of the analysis is that the method of determining frost mass by continuous weighing and frost density by inference from pressure drop considerations, which is presented in the report, has the potential to produce results with an accuracy on a par with the best previously used techniques to investigate frosting and defrosting phenomena. Furthermore, the methodology has the distinct advantage of yielding online measuring possibilities and being much less time consuming than traditional techniques.

  5. Organic Rankine-cycle turbine power plant utilizing low temperature heat sources

    Science.gov (United States)

    Maizza, V.

    1980-03-01

    Utilizing and converting of existing low temperature and waste heat sources by the use of a high efficiency bottoming cycle is attractive and should be possible for many locations. This paper presents a theoretical study on possible combination of an organic Rankine-cycle turbine power plate with the heat pump supplied by waste energy sources. Energy requirements and system performances are analyzed using realistic design operating condition for a middle town. Some conversion systems employing working fluids other than water are being studied for the purpose of proposed application. Thermodynamic efficiencies, with respect to available resource, have been calculated by varying some system operating parameters at various reference temperature. With reference to proposed application equations and graphs are presented which interrelate the turbine operational parameters for some possible working fluids with computation results.

  6. Performance prediction between horizontal and vertical source heat pump systems for greenhouse heating with the use of artificial neural networks

    Science.gov (United States)

    Benli, Hüseyin

    2016-08-01

    This paper presents the suitability of artificial neural networks (ANNs) to predict the performance and comparison between a horizontal and a vertical ground source heat pump system. Performance forecasting is the precondition for the optimal control and energy saving operation of heat pump systems. In this study, performance parameters such as air temperature entering condenser fan-coil unit, air temperature leaving condenser fan-coil unit, and ground temperatures (2 and 60 m) obtained experimental studies are input data; coefficient of performance of system (COPsys) is in output layer. The back propagation learning algorithm with three different variants such as Levenberg-Marguardt, Pola-Ribiere conjugate gradient, and scaled conjugate gradient, and also tangent sigmoid transfer function were used in the network so that the best approach can be found. The results showed that LM with three neurons in the hidden layer is the most suitable algorithm with maximum correlation coefficients R2 of 0.999, minimum root mean square RMS value and low coefficient variance COV. The reported results confirmed that the use of ANN for performance prediction of COPsys,H-V is acceptable in these studies.

  7. A new power generation method utilizing a low grade heat source

    Institute of Scientific and Technical Information of China (English)

    Wei-feng WU; Kin-ping LONG; Xiao-ling YU; Quan-ke FENG

    2012-01-01

    Energy crisis make the effective use of low grade energy more and more urgent.It is still a worldwide difficult conundrum.To efficiently recover low grade heat,this paper deals with a theoretical analysis of a new power generation method driven by a low grade heat source.When the temperature of the low grade heat source exceeds the saturated temperature,it can heat the liquid into steam.If the steam is sealed and cooled in a container,it will lead to a negative pressure condition.The proposed power generation method utilizes the negative pressure condition in the sealed container,called as a condensator.When the condensator is connected to a liquid pool,the liquid will be pumped into it by the negative pressure condition.After the condensator is filled by liquid,the liquid flows back into the pool and drives the turbine to generate electricity.According to our analysis,for water,the head pressure of water pumped into the condensator could reach 9.5 m when the temperature of water in the pool is 25 ℃,and the steam temperature is 105 ℃.Theoretical thermal efficiency of this power generation system could reach 3.2% to 5.8% varying with the altitude of the condensator to the water level,ignoring steam leakage loss.

  8. 铁路站房地源热泵系统工程热平衡分析%Analysis on Heat Balance of Ground Source Heat Pump System in Railway Station

    Institute of Scientific and Technical Information of China (English)

    沈德安

    2013-01-01

    Abstract:In regard to an actual railway station,based on its design circumstance of air-condition heating system and its testing report of ground heat transfer characteristics,the ground source heat pump system was adopted as its cold and heat source.Considering the need for heat balance of the ground source heat pump system,this thesis analyzes the two different schemes used in railway station buildings:the one is a ground source heat pump system assisted by boiler,and the other is a coupled system of solar energy with ground source heat pump.And then respectively for both schemes,this thesis calculates the required capacity of ground source heat pump unit and the required design scale of ground heat exchanger.This thesis also discusses how to achieve the cold and heat balance for the two different schemes,and analyzes each characteristics and applicability in actual projects.Finally this thesis points out:it is necessary to use suitable and customized heat balance modes for different projects on the basis of local conditions.%结合具体工程,根据某车站空调采暖系统设计工况及该工程地埋管换热特性测试报告,采用地源热泵系统作为冷热源.考虑地源热泵系统的冷热平衡需要,分析采用地源热泵+锅炉辅助系统及太阳能地源热泵耦合系统两种不同热平衡方案用于铁路站房,计算各自需要的热泵机组容量及室外埋管换热器具体设计规模.详细介绍两种系统的冷热平衡方式,并对各自特点及工程运用进行论述,提出在具体工程中因地制宜,应根据不同情况,采用合适的系统热平衡方式.

  9. Finite line-source model for borehole heat exchangers. Effect of vertical temperature variations

    Energy Technology Data Exchange (ETDEWEB)

    Bandos, Tatyana V.; Fernandez, Esther; Santander, Juan Luis G.; Isidro, Jose Maria; Perez, Jezabel; Cordoba, Pedro J. Fernandez de [Instituto Universitario de Matematica Pura y Aplicada, Universidad Politecnica de Valencia, Camino de Vera s/n, 46022 Valencia (Spain); Montero, Alvaro; Urchueguia, Javier F. [Instituto de Ingenieria Energetica, Universidad Politecnica de Valencia, Camino de Vera s/n, 46022 Valencia (Spain)

    2009-06-15

    A solution to the three-dimensional finite line-source (FLS) model for borehole heat exchangers (BHEs) that takes into account the prevailing geothermal gradient and allows arbitrary ground surface temperature changes is presented. Analytical expressions for the average ground temperature are derived by integrating the exact solution over the line-source depth. A self-consistent procedure to evaluate the in situ thermal response test (TRT) data is outlined. The effective thermal conductivity and the effective borehole thermal resistance can be determined by fitting the TRT data to the time-series expansion obtained for the average temperature. (author)

  10. Open Source GIS based integrated watershed management

    Science.gov (United States)

    Byrne, J. M.; Lindsay, J.; Berg, A. A.

    2013-12-01

    Optimal land and water management to address future and current resource stresses and allocation challenges requires the development of state-of-the-art geomatics and hydrological modelling tools. Future hydrological modelling tools should be of high resolution, process based with real-time capability to assess changing resource issues critical to short, medium and long-term enviromental management. The objective here is to merge two renowned, well published resource modeling programs to create an source toolbox for integrated land and water management applications. This work will facilitate a much increased efficiency in land and water resource security, management and planning. Following an 'open-source' philosophy, the tools will be computer platform independent with source code freely available, maximizing knowledge transfer and the global value of the proposed research. The envisioned set of water resource management tools will be housed within 'Whitebox Geospatial Analysis Tools'. Whitebox, is an open-source geographical information system (GIS) developed by Dr. John Lindsay at the University of Guelph. The emphasis of the Whitebox project has been to develop a user-friendly interface for advanced spatial analysis in environmental applications. The plugin architecture of the software is ideal for the tight-integration of spatially distributed models and spatial analysis algorithms such as those contained within the GENESYS suite. Open-source development extends knowledge and technology transfer to a broad range of end-users and builds Canadian capability to address complex resource management problems with better tools and expertise for managers in Canada and around the world. GENESYS (Generate Earth Systems Science input) is an innovative, efficient, high-resolution hydro- and agro-meteorological model for complex terrain watersheds developed under the direction of Dr. James Byrne. GENESYS is an outstanding research and applications tool to address

  11. Combined Cycle for Power Generation and Refrigeration Using Low Temperature Heat Sources

    OpenAIRE

    Vijay Chauhan; P. Anil Kishan; Sateesh Gedupudi

    2014-01-01

    A combined refrigeration and power cycle, which uses ammonia-water as the working fluid, is proposed by combining Rankine and vapour absorption cycles with an advantage of varying refrigeration capacity to power output ratio. The study investigates the usage of low temperature heat sources for the cycle operation. Results of parametric analysis are presented, which show the scope for optimization. Results of thermodynamic optimization of the cycle for second law efficiency performed using gen...

  12. Free convection of a nanofluid in a square cavity with a heat source on the bottom wall and partially cooled from sides

    Directory of Open Access Journals (Sweden)

    Mahmoodi Mostafa

    2014-01-01

    Full Text Available The problem of free convection fluid flow and heat transfer in a square cavity with a flush mounted heat source on its bottom wall and two heat sinks on its vertical side walls has been investigated numerically. Via changing the location of the heat sinks, six different arrangements have been generated. The cavity was filled with Cu-water nanofluid. The governing equations were discretized using the finite volume method and SIMPLER algorithm. Using the developed code, a parametric study was undertaken, and effects of Rayleigh number, arrangements of the heat sinks and volume fraction of the nanoparticles on fluid flow and heat transfer inside the cavity were investigated. Also for the middle-middle heat sinks arrangement, capability of five different water based nanofluids on enhancement of the rate of heat transfer was examined and compared. From the obtained results it was found that the average Nusselt number, for all six different arrangements of the heat sinks, was an increasing function of the Rayleigh number and the volume fraction of the nanoparticles. Also it was found that at high Rayleigh numbers, maximum and minimum average Nusselt number occurred for middle-middle and top-bottom arrangement, respectively. Moreover it was found that for the middle-middle arrangement, at high Rayleigh numbers, maximum and minimum rate of heat transfer was obtained by Cu-water and TiO2-water nanofluids respectively.

  13. Geometric Characteristics of Methane Steam Reforming with Low Temperature Heat Source

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Gahui; Yun, Jinwon; Yu, Sangseok [Chungnam Nat’l Univ., Daejeon (Korea, Republic of)

    2016-12-15

    In a hybrid fuel cell system, low-temperature reforming technology, which uses waste heat as a heat source, is applied to improve system efficiency. A low temperature reformer is required to optimize geometry in low thermal conditions so that the reformer can achieve the proper methane conversion rate. This study analyzed internal temperature distributions and the reaction patterns of a reformer by considering the change of the shape factor on the limited heat supply condition. Unlike the case of a high temperature reformer, analysis showed that the reaction of a low temperature reformer takes place primarily in the high temperature region of the reactor exit. In addition, it was confirmed that the efficiency can be improved by reducing the GHSV (gas hourly space velocity) or increasing the heat transfer area in the radial direction. Through reacting characteristic analysis, according to change of the aspect ratio, it was confirmed that a low temperature reformer can improve the efficiency by increasing the heat transfer in the radial direction, rather than in the longitudinal direction.

  14. Model for the heat source of the Cerro Prieto magma-hydrothermal system, Baja California, Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Elders, W.A.; Bird, D.K.; Williams, A.E.; Schiffman, P.; Cox, B.

    1981-01-01

    Earlier studies at Cerro Prieto led to the development of a qualitative model for fluid flow in the geothermal system before it was drilled and perturbed by production. Current efforts are directed towards numerical modeling of heat and mass transfer in the system in this undisturbed state. This one-dimensional model assumes that the heat source was a single basalt/gabbro intrusion which provided heat to the system as it cooled. After compilation of various information of the physical properties of the reservoir, the enthalpy contained in two 1 cm thick sections across the reservoir orthogonal to each other was calculated. Various shapes, sizes and depths for the intrusion were considered as initial conditions and boundary conditions for the calculations of heat transfer. A family of numerical models which so far gives the best matches to the conditions observed in the field today have in common a funnel-shaped intrusion with a top 4 km wide emplaced at a depth of 5 km some 30,000 to 50,000 years ago, providing heat to the geothermal system.

  15. A strong shallow heat source in the accreting neutron star MAXI J0556-332

    CERN Document Server

    Deibel, Alex; Brown, Edward F; Page, Dany

    2015-01-01

    An accretion outburst in an X-ray transient deposits material onto the neutron star primary; this accumulation of matter induces reactions in the neutron star's crust. During the accretion outburst these reactions heat the crust out of thermal equilibrium with the core. When accretion halts, the crust cools to its long-term equilibrium temperature on observable timescales. Here we examine the accreting neutron star transient MAXI J0556-332, which is the hottest transient, at the start of quiescence, observed to date. Models of the quiescent light curve require a large deposition of heat in the shallow outer crust from an unknown source. The additional heat injected is $\\approx 4\\textrm{-}10\\,\\mathrm{MeV}$ per accreted nucleon; when the observed decline in accretion rate at the end of the outburst is accounted for, the required heating increases to $\\approx 6\\textrm{-}16\\,\\mathrm{MeV}$. This shallow heating is still required to fit the lightcurve even after taking into account a second accretion episode, uncer...

  16. Energy Efficiency Modelling of Residential Air Source Heat Pump Water Heater

    Directory of Open Access Journals (Sweden)

    Cong Toan Tran

    2016-03-01

    Full Text Available The heat pump water heater is one of the most energy efficient technologies for heating water for household use. The present work proposes a simplified model of coefficient of performance and examines its predictive capability. The model is based on polynomial functions where the variables are temperatures and the coefficients are derived from the Australian standard test data, using regression technics. The model enables to estimate the coefficient of performance of the same heat pump water heater under other test standards (i.e. US, Japanese, European and Korean standards. The resulting estimations over a heat-up phase and a full test cycle including a draw off pattern are in close agreement with the measured data. Thus the model allows manufacturers to avoid the need to carry out physical tests for some standards and to reduce product cost. The limitations of the methodology proposed are also discussed.

  17. Construction Technology of Soil Source Heat Exchanger of Ground Source Heat Pump%地源热泵土壤源换热器的施工技术

    Institute of Scientific and Technical Information of China (English)

    程金明; 王巧真

    2007-01-01

    地源热泵(Ground Source Heat Pump, GSHP)作为最有发展潜力的热泵技术在各级政府的积极推介下发展迅速,但由于地源换热器施工安装成本高,技术的发展遇到了很大的阻力.探讨了土壤源换热器施工技术和土壤源换热器的热平衡问题,力图提高土源换热器施工技术,降低地源热泵成本,促进该技术的推广应用.

  18. Crank-Nicholson Scheme for the Estimation of Thermal Disturbance on the Peripheral Tissues of Human Body Subjected to Oscillatory Boundary Condition and Time Dependent Heat Source

    Science.gov (United States)

    Khanday, M. A.; Hussain, Fida

    2015-07-01

    To predict the behaviour of thermal physiology of a finite biological tissue in severe cold climatic conditions, a mathematical model has been established based on Pennes' bio-heat transfer equation with oscillatory boundary condition and time dependent heat source term. Crank-Nicholson scheme has been employed to obtain the solution of the boundary value problem to understand the change in stable temperature profiles at the peripheral tissues of human body subjected to forced convection due to cold. Thermal stress at these regions with respect to different input parameters has been computed under extreme environmental conditions using MATLAB Software. The results have shown a relative significance and provide a reasonable outcome in terms of variable metabolic heat generation and oscillatory heat source. The oscillations of the temperature profiles from the mean temperatures were computed in relation with tissue medium and other physiological parameters.

  19. Case Study for the ARRA-funded Ground Source Heat Pump Demonstration at Denver Museum of Nature & Science

    Energy Technology Data Exchange (ETDEWEB)

    Im, Piljae [ORNL; Liu, Xiaobing [ORNL

    2016-09-01

    High initial costs and lack of public awareness of ground-source heat pump (GSHP) technology are the two major barriers preventing rapid deployment of this energy-saving technology in the United States. Under the American Recovery and Reinvestment Act (ARRA), 26 GSHP projects were competitively selected and carried out to demonstrate the benefits of GSHP systems and innovative technologies for cost reduction and/or performance improvement. This report highlights the findings of a case study of one such GSHP demonstration projects that uses a recycled water heat pump (RWHP) system installed at the Denver Museum of Nature & Science in Denver, Colorado. The RWHP system uses recycled water from the city’s water system as the heat sink and source for a modular water-to-water heat pump (WWHP). This case study was conducted based on the available measured performance data from December 2014 through August 2015, utility bills of the building in 2014 and 2015, construction drawings, maintenance records, personal communications, and construction costs. The annual energy consumption of the RWHP system was calculated based on the available measured data and other related information. It was compared with the performance of a baseline scenario— a conventional VAV system using a water-cooled chiller and a natural gas fired boiler, both of which have the minimum energy efficiencies allowed by ASHRAE 90.1-2010. The comparison was made to determine energy savings, operating cost savings, and CO2 emission reductions achieved by the RWHP system. A cost analysis was performed to evaluate the simple payback of the RWHP system. Summarized below are the results of the performance analysis, the learned lessons, and recommended improvement in the operation of the RWHP system.

  20. Case Study for the ARRA-funded Ground Source Heat Pump Demonstration at Denver Museum of Nature & Science

    Energy Technology Data Exchange (ETDEWEB)

    Im, Piljae [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Energy and Transportation Science Division; Liu, Xiaobing [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Energy and Transportation Science Division

    2015-11-30

    High initial costs and lack of public awareness of ground-source heat pump (GSHP) technology are the two major barriers preventing rapid deployment of this energy-saving technology in the United States. Under the American Recovery and Reinvestment Act (ARRA), 26 GSHP projects were competitively selected and carried out to demonstrate the benefits of GSHP systems and innovative technologies for cost reduction and/or performance improvement. This report highlights the findings of a case study of one such GSHP demonstration projects that uses a recycled water heat pump (RWHP) system installed at the Denver Museum of Nature & Science in Denver, Colorado. The RWHP system uses recycled water from the city’s water system as the heat sink and source for a modular water-to-water heat pump (WWHP). This case study was conducted based on the available measured performance data from December 2014 through August 2015, utility bills of the building in 2014 and 2015, construction drawings, maintenance records, personal communications, and construction costs. The annual energy consumption of the RWHP system was calculated based on the available measured data and other related information. It was compared with the performance of a baseline scenario— a conventional VAV system using a water-cooled chiller and a natural gas fired boiler, both of which have the minimum energy efficiencies allowed by ASHRAE 90.1-2010. The comparison was made to determine energy savings, operating cost savings, and CO2 emission reductions achieved by the RWHP system. A cost analysis was performed to evaluate the simple payback of the RWHP system. Summarized below are the results of the performance analysis, the learned lessons, and recommended improvement in the operation of the RWHP system.

  1. Optimization of systems with the combination of ground-source heat pump and solar collectors in dwellings

    DEFF Research Database (Denmark)

    Kjellsson, Elisabeth; Hellström, Göran; Perers, Bengt

    2010-01-01

    The use of ground-source heat pumps for heating and domestic hot water in dwellings is common in Sweden. The combination with solar collectors has been introduced to reduce the electricity demand in the system. In order to analyze different systems with combinations of solar collectors and ground......-source heat pumps, computer simulations have been carried out with the simulation program TRNSYS. Large differences were found between the system alternatives. The optimal design is when solar heat produces domestic hot water during summertime and recharges the borehole during wintertime. The advantage...... is related to the rate of heat extraction from the borehole as well as the overall design of the system. The demand of electricity may increase with solar recharging, because of the increased operating time of the circulation pumps. Another advantage with solar heat in combination with heat pumps is when...

  2. Effect of heat radiation in a Walter’s liquid B fluid over a stretching sheet with non-uniform heat source/sink and elastic deformation

    Directory of Open Access Journals (Sweden)

    A.K. Abdul Hakeem

    2014-07-01

    Full Text Available In this present article heat transfer in a Walter’s liquid B fluid over an impermeable stretching sheet with non-uniform heat source/sink, elastic deformation and radiation are reported. The basic boundary layer equations for momentum and heat transfer, which are non-linear partial differential equations, are converted into non-linear ordinary differential equations by means of similarity transformation. The dimensionless governing equations for this investigation are solved analytically using hyper geometric functions. The results are carried out for prescribed surface temperature (PST and prescribed power law surface heat flux (PHF. The effects of viscous dissipation, Prandtl number, Eckert number, heat source/sink parameter with elastic deformation and radiation are shown in the several plots and addressed.

  3. The Analysis of Ground Source Heat Pump Applied in Mianyang City%地源热泵在绵阳地区的应用分析

    Institute of Scientific and Technical Information of China (English)

    刘东; 蒋斌; 韩如冰; 邹国荣

    2013-01-01

      介绍了地源热泵的工作原理,并结合绵阳地区的地质情况及地源热泵系统形式,分析了地源热泵技术在绵阳地区的应用方式,并针对地表水、地下水和地下耦合地源热泵系统的可行性进行了分析和说明,为地源热泵技术在绵阳地区的工程应用提供参考。%This paper introduced the operational principle of ground source heat pump. Based on the geologic environment of Mianyang city and the ground source heat pump forms, the application of different ground source heat pump were compared. And analyses the feasibility of surface water,ground water and underground coupling source heat pump in Mianyang city. This paper can provide the reference for the ground source heat pump engineering application in Mianyang city.

  4. Measuring Modularity in Open Source Code Bases

    Directory of Open Access Journals (Sweden)

    Roberto Milev

    2009-03-01

    Full Text Available Modularity of an open source software code base has been associated with growth of the software development community, the incentives for voluntary code contribution, and a reduction in the number of users who take code without contributing back to the community. As a theoretical construct, modularity links OSS to other domains of research, including organization theory, the economics of industry structure, and new product development. However, measuring the modularity of an OSS design has proven difficult, especially for large and complex systems. In this article, we describe some preliminary results of recent research at Carleton University that examines the evolving modularity of large-scale software systems. We describe a measurement method and a new modularity metric for comparing code bases of different size, introduce an open source toolkit that implements this method and metric, and provide an analysis of the evolution of the Apache Tomcat application server as an illustrative example of the insights gained from this approach. Although these results are preliminary, they open the door to further cross-discipline research that quantitatively links the concerns of business managers, entrepreneurs, policy-makers, and open source software developers.

  5. Heat transfer performance of a pulsating heat pipe charged with acetone-based mixtures

    Science.gov (United States)

    Wang, Wenqing; Cui, Xiaoyu; Zhu, Yue

    2017-06-01

    Pulsating heat pipes (PHPs) are used as high efficiency heat exchangers, and the selection of working fluids in PHPs has a great impact on the heat transfer performance. This study investigates the thermal resistance characteristics of the PHP charged with acetone-based binary mixtures, where deionized water, methanol and ethanol were added to and mixed with acetone, respectively. The volume mixing ratios were 2:1, 4:1 and 7:1, and the heating power ranged from 10 to 100 W with filling ratios of 45, 55, 62 and 70%. At a low filling ratio (45%), the zeotropic characteristics of the binary mixtures have an influence on the heat transfer performance of the PHP. Adding water, which has a substantially different boiling point compared with that of acetone, can significantly improve the anti-dry-out ability inside the PHP. At a medium filling ratio (55%), the heat transfer performance of the PHP is affected by both phase transition characteristics and physical properties of working fluids. At high heating power, the thermal resistance of the PHP with acetone-water mixture is between that with pure acetone and pure water, whereas the thermal resistance of the PHP with acetone-methanol and acetone-ethanol mixtures at mixing ratios of 2:1 and 4:1 is less than that with the corresponding pure fluids. At high filling ratios (62 and 70%), the heat transfer performance of the PHP is mainly determined by the properties of working fluids that affects the flow resistance. Thus, the PHP with acetone-methanol and acetone-ethanol mixtures that have a lower flow resistance shows better heat transfer performance than that with acetone-water mixture.

  6. Heat transfer performance of a pulsating heat pipe charged with acetone-based mixtures

    Science.gov (United States)

    Wang, Wenqing; Cui, Xiaoyu; Zhu, Yue

    2016-12-01

    Pulsating heat pipes (PHPs) are used as high efficiency heat exchangers, and the selection of working fluids in PHPs has a great impact on the heat transfer performance. This study investigates the thermal resistance characteristics of the PHP charged with acetone-based binary mixtures, where deionized water, methanol and ethanol were added to and mixed with acetone, respectively. The volume mixing ratios were 2:1, 4:1 and 7:1, and the heating power ranged from 10 to 100 W with filling ratios of 45, 55, 62 and 70%. At a low filling ratio (45%), the zeotropic characteristics of the binary mixtures have an influence on the heat transfer performance of the PHP. Adding water, which has a substantially different boiling point compared with that of acetone, can significantly improve the anti-dry-out ability inside the PHP. At a medium filling ratio (55%), the heat transfer performance of the PHP is affected by both phase transition characteristics and physical properties of working fluids. At high heating power, the thermal resistance of the PHP with acetone-water mixture is between that with pure acetone and pure water, whereas the thermal resistance of the PHP with acetone-methanol and acetone-ethanol mixtures at mixing ratios of 2:1 and 4:1 is less than that with the corresponding pure fluids. At high filling ratios (62 and 70%), the heat transfer performance of the PHP is mainly determined by the properties of working fluids that affects the flow resistance. Thus, the PHP with acetone-methanol and acetone-ethanol mixtures that have a lower flow resistance shows better heat transfer performance than that with acetone-water mixture.

  7. Existing climate data sources and Their Use in Heat IslandResearch

    Energy Technology Data Exchange (ETDEWEB)

    Akbari, Hashem; Pon, Brian; Smith, Craig Kenton; Stamper-Kurn, Dan Moses

    1998-10-01

    Existing climate data sources can be used in two general types of analysis for the detection of urban heat islands. Historical analyses use long-term data records-preferentially from several locations in and around an urban area-to trace the gradual influence of urban development on its climate. Primary sources of such data include the cooperative network, first-order National Weather Service stations, and military weather stations. Analyses of short-term data use information from a dense urban weather station network to discern the location, extent, and magnitude of urban heat islands. Such analyses may use the aforementioned national networks or regional networks such as agricultural, air quality monitoring, or utility networks. We demonstrate the use of existing data sources with a historical analysis of temperature trends in Los Angeles, California, and an analysis of short-term data of the urban temperature profile for Phoenix, Arizona. The Los Angeles climate was examined with eleven long-term data records from the cooperative network. Statistically significant trends of rising temperature were detected at Los Angeles Civic Center and other stations over some parts of the year, although timing of the increase varied from station to station. Observed increases in temperatures maybe due to long-term climate changes, microclimate influences, or local-scale heat islands. The analysis of short-term data was made for Phoenix using the PRISMS station network. Mean diurnal temperature profiles for a month were examined and compared with those for adjacent rural areas. Data fi-om stations in the center of Phoenix showed clear and significant nighttime and daytime temperature differences of 1- 2K (3 - 4"F). These temperature increases maybe attributable to a local-scale heat island.

  8. Source extension based on ε-entropy

    Institute of Scientific and Technical Information of China (English)

    ZHANG Jian; YU Sheng-sheng; ZHOU Jing-li; ZHENG Xin-wei

    2005-01-01

    It is known by entropy theory that image is a source correlated with a certain characteristic of probability. The entropy rate of the source and ? entropy (rate-distortion function theory) are the information content to identify the characteristics of video images, and hence are essentially related with video image compression. They are fundamental theories of great significance to image compression, though impossible to be directly turned into a compression method. Based on the entropy theory and the image compression theory, by the application of the rate-distortion feature mathematical model and Lagrange multipliers to some theoretical problems in the H.264 standard, this paper presents a new the algorithm model of coding rate-distortion. This model is introduced into complete test on the capability of the test model of JM61e (JUT Test Model). The result shows that the speed of coding increases without significant reduction of the rate-distortion performance of the coder.

  9. A critical evaluation of semianalytic methods in the study of centrally heated, unresolved, infrared sources

    Science.gov (United States)

    Doty, Steven D.; Leung, Chun Ming

    1994-01-01

    We critically evaluate current methods of analysis in infrared (IR) astronomy and investigate the conditions under which these semianalytic methods are reliable. Specifically we examine the usual assumptions of homogeneities in dust density and temperature, and neglect of opacity effects when applied to internally heated, unresolved IR sources. To accomplish this, a series of radiation transport models for these sources have been constructed. The model results are treated as observed quantities and analyzed to derive the source parameters, using simple semianalytic methods. The discrepancies between the derived and actual model parameters can then be attributed to the limitations of the analysis methods and provide a measure of their reliability. Applying this approach to centrally heated, unresolved IR sources, we have studied in detail the following diagnostic problems: (1) determination of dust mass from monochromatic and integrated luminosities; (2) estimation of dust temperature distribution from color temperatures derived from the flux spectrum; and (3) determination of the empirical grain emissivity law (opacity function) for both continuum and spectral features.

  10. Enhanced primary sludge sonication by heat insulation to reclaim carbon source for biological phosphorous removal.

    Science.gov (United States)

    Tian, Qing; Wang, Qi; Zhu, Yanbing; Li, Fang; Zhuang, Lin; Yang, Bo

    2017-01-01

    Ultrasound pretreatment is a potent step to disintegrate primary sludge (PS). The supernatant of sonicated PS is recycled as an alternative carbon source for biological phosphorus removal. In this study, we investigated the role of temperature on PS disintegration during sonication. We found that a temperature of 60°C yielded a dissolution rate of about 2% soluble chemical oxygen demand (SCOD) as compared to 7% SCOD using sonication at the specific energy (SE) of 7359kJ/kg TS. Using the SE of 6000kJ/kg TS with heat insulation during sonication, the SCOD dissolution rate of PS was similar to the result at the SE of 7051kJ/kg TS without heat insulation. Upon treatment with sonication, the PS released low concentrations of Cu and Zn into the supernatant. The phosphorus-accumulating organisms (PAOs) used the supernatant of sonicated PS as the carbon source. Supplementation with the diluted sonicated PS supernatant (SCOD≈1000mg/L) in anaerobic phase resulted in the release of phosphorus (36mg/L) and the production of polyhydroxyalkanoates (PHAs) (0.36g PHA/g SS). Compared with sodium acetate, higher polyhydroxyvalerate (PHV) faction in the polyhydroxyalkanoates (PHAs) was observed in the biomass when incubated with sonicated PS as the carbon source. This work provides a simple pathway to conserve energy and to enhance efficiencies of ultrasonic pretreatment and the recovery of carbon source from the sludge for improving the phosphorus removal in the ENR system.

  11. Optimization-based design of a heat flux concentrator

    Science.gov (United States)

    Peralta, Ignacio; Fachinotti, Víctor D.; Ciarbonetti, Ángel A.

    2017-01-01

    To gain control over the diffusive heat flux in a given domain, one needs to engineer a thermal metamaterial with a specific distribution of the generally anisotropic thermal conductivity throughout the domain. Until now, the appropriate conductivity distribution was usually determined using transformation thermodynamics. By this way, only a few particular cases of heat flux control in simple domains having simple boundary conditions were studied. Thermal metamaterials based on optimization algorithm provides superior properties compared to those using the previous methods. As a more general approach, we propose to define the heat control problem as an optimization problem where we minimize the error in guiding the heat flux in a given way, taking as design variables the parameters that define the variable microstructure of the metamaterial. In the present study we numerically demonstrate the ability to manipulate heat flux by designing a device to concentrate the thermal energy to its center without disturbing the temperature profile outside it. PMID:28084451

  12. Base fluid in improving heat transfer for EV car battery

    Science.gov (United States)

    Bin-Abdun, Nazih A.; Razlan, Zuradzman M.; Shahriman, A. B.; Wan, Khairunizam; Hazry, D.; Ahmed, S. Faiz; Adnan, Nazrul H.; Heng, R.; Kamarudin, H.; Zunaidi, I.

    2015-05-01

    This study examined the effects of base fluid (as coolants) channeling inside the heat exchanger in the process of the increase in thermal conductivity between EV car battery and the heat exchanger. The analysis showed that secondary cooling system by means of water has advantages in improving the heat transfer process and reducing the electric power loss on the form of thermal energy from batteries. This leads to the increase in the efficiency of the EV car battery, hence also positively reflecting the performance of the EV car. The present work, analysis is performed to assess the design and use of heat exchanger in increasing the performance efficiency of the EV car battery. This provides a preface to the use this design for nano-fluids which increase and improve from heat transfer.

  13. 地源热泵单U型地埋管换热器的传热模拟分析%Simulation Analysis of Single U-tube Underground Heat Exchanger for Ground Source Heat Pump

    Institute of Scientific and Technical Information of China (English)

    张晓伟; 曹红奋

    2016-01-01

    Aunderground heat exchanger heat transfer model for single U -tube underground heat exchanger was es-tablished based on the heat transfer characteristics of the ground source heat pump .The influences of the different in-let water temperature , different flow rate and different backfill materials on the single U -tube underground heat ex-changer capability were simulation analysis .The results may provide guidance for the same type of ground source heat pump.%本文针对地源热泵单U型地埋管换热器的换热特性,建立了地埋管换热器的传热模型,模拟分析了不同的进口水温、不同的流速以及不同的回填材料对单U型地埋管换热器换热能力的影响,研究结果可为同类型的地源热泵项目提供参考和借鉴。

  14. The feasibility of retrieving nuclear heat sources from orbit with the space shuttle

    Energy Technology Data Exchange (ETDEWEB)

    Pyatt, D.W.; Englehart, R.W.

    1980-01-01

    Spacecraft launched for orbital missions have a finite orbital lifetime. Current estimates for the lifetime of the nine nuclear powered U.S. satellites now in orbit range from 150 years to 10{sup 6} years. Orbital lifetime is determined primarily by altitude, solar activity, and the satellite ballistic coefficient. There is also the potential of collision with other satellites or space debris, which would reduce the lifetime in orbit. These orbiting power sources contain primarily Pu-238 and Pu-239 as the fuel material. Pu-238 has an approximate 87-year half life and so considerable amounts of daughter products are present after a few tens of years. In addition, there are minor but possibly significant amounts of impurity isotopes present with their own decay chains. Radioisotopic heat sources have been designed to evolving criteria since the first launches. Early models were designed to burn up upon reentry. Later designs were designed to reenter intact. After tens or hundreds of years in orbit, the ability of any orbiting heat source to reenter intact and impact while maintaining containment integrity is in doubt. Such ability could only be verified by design to provide protection in the case of early mission failures such as launch aborts, failure to achieve orbit, or the attainment of only a short orbit. With the development of the Space Shuttle there exists the potential ability to recover heat sources in orbit after their missions are completed. Such retrieval could allow the risk of eventual reentry burnup or impact with atmospheric dispersion and subsequent radiation doses to the public to be avoided.

  15. Focus group discussions among owners and non-owners of ground source heat pumps

    Energy Technology Data Exchange (ETDEWEB)

    Roberson, B.F.

    1988-07-01

    This research was sponsored by the Office of Buildings and Community Systems and conducted by the Pacific Northwest Laboratory as part of an ongoing effort to enhance the commercial use of federally developed technology. Federal dollars have supported research on the development of ground source heat pumps (GSHP) for several years. Though several companies currently sell GSHP's for residential use, their share of the total heating and air conditioning business remains less than one percent. Large manufacturing companies with national distribution have not yet added GSHP equipment to their product line. GSHP's use only about one half (Braud 1987) to one third (Bose 1987) of the energy needed to operate conventional furnaces and air conditioners. Consequently, a high level of market penetration by the GSHP offers direct benefits to both utility companies and individual users of the systems. Widespread use of these highly efficient systems will reduce both total energy consupmtion, and problems associated with high levels of energy use during peak periods. This will allow utility companies to delay capital expenditures for new facilities to meet the growing energy demand during peak periods. The cost effective use of electricity also reduces the likelihood of homeowners switching to a different fuel source for heating. 5 refs.

  16. Preliminary analysis on the relationships between Tibetan Plateau NDVI change and its surface heat source and precipitation of China

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    Using the automatic weather station data obtained from the Tibetan Plateau (TP), the normalized dif- ference vegetation index and the monthly precipitation data of China and by the methods of correlation and composite analysis, preliminary analytical results are achieved concerning the relationships be- tween TP NDVI change and its surface heat source and precipitation of China. The results of our re- search may lead to the following conclusions: (1) A positive correlation relationship exists between TP NDVI change and its surface heat source, including the sensible heat and the latent heat. As to the correlation of the former, it is more remarkable in western TP than in eastern TP, and as to the correla- tion of the latter, however it turns out contrary. (2) With the improvement of TP vegetation, its surface heat source of every season is also mainly reinforced, especially in summer. As to the contribution of the sensible heat and the latent heat to the increment of the TP surface heat source intensity, the for- mer is comparatively more significant than the latter in winter and spring, while in summer and autumn, the two have almost the same importance. (3) The correlation coefficient between summer NDVI over TP and the corresponding period precipitation of China displays a belt distribution of "+?+" from south to north China. (4) Anomalous surface heating field over TP derived from vegetation change is probably an important factor to affect summer precipitation of China.

  17. Transient natural ventilation of a room with a distributed heat source

    Science.gov (United States)

    Fitzgerald, Shaun D.; Woods, Andrew W.

    We report on an experimental and theoretical study of the transient flows which develop as a naturally ventilated room adjusts from one temperature to another. We focus on a room heated from below by a uniform heat source, with both high- and low-level ventilation openings. Depending on the initial temperature of the room relative to (i) the final equilibrium temperature and (ii) the exterior temperature, three different modes of ventilation may develop. First, if the room temperature lies between the exterior and the equilibrium temperature, the interior remains well-mixed and gradually heats up to the equilibrium temperature. Secondly, if the room is initially warmer than the equilibrium temperature, then a thermal stratification develops in which the upper layer of originally hot air is displaced upwards by a lower layer of relatively cool inflowing air. At the interface, some mixing occurs owing to the effects of penetrative convection. Thirdly, if the room is initially cooler than the exterior, then on opening the vents, the original air is displaced downwards and a layer of ambient air deepens from above. As this lower layer drains, it is eventually heated to the ambient temperature, and is then able to mix into the overlying layer of external air, and the room becomes well-mixed. For each case, we present new laboratory experiments and compare these with some new quantitative models of the transient flows. We conclude by considering the implications of our work for natural ventilation of large auditoria.

  18. 浙北地区地源热泵土壤换热性能测试研究%Study on Measurement of Heat Transfer Characteristics of Ground Source in a Ground Source Heat Pump System in Northern Zhejiang

    Institute of Scientific and Technical Information of China (English)

    刘晓勤; 郑锦龙; 郑翀

    2011-01-01

    The heat transfer characteristics of ground source in Ground Source Heat Pump (GSHP) in Northem Zhejiang were experimentally measured. The experimental results showed that the initial ground source temperature in the coldest month was approximately 17.0℃, which was significantly higher than the temperature of the outside environment. The mean thermal conductivity of the ground source was 1.73W/(m· ℃). It indicated that the ground source had good heat transfer capacity and could be used for the ground source heat pump system. The experimental measurement of the heat transfer coefficient was also conducted on a single U type underground heat exchanger at the depth of 60 m. The experimental results showed that the heat dissipating capacity of the single pipe were 3666W in summer and 2508 W in winter, respectively. The heat dissipating capacity could meet the requirement of the ground source heat pump system.%对浙北地区某地源热泵工程土壤换热性能进行了实验测试,结果显示,浙北地区冬季最冷月地下土壤初始温度稳定在17.0℃左右,远高于室外环境温度;土壤的平均导热系数为1.73W/(m·℃),有较强的地下换热能力,适合做地源热泵系统;对60m深的单U形式地下换热器进行换热性能测试,夏季单根盘管散热量3666W,冬季单根盘管散热量2508W,能满足系统工作要求。

  19. Characterization of zeolite-based coatings for adsorption heat pumps

    CERN Document Server

    Freni, Angelo; Bonaccorsi, Lucio; Chmielewski, Stefanie; Frazzica, Andrea; Calabrese, Luigi; Restuccia, Giovanni

    2015-01-01

    This book proposes a radically new approach for characterizing thermophysical and mechanical properties of zeolite-based adsorbent coatings for Adsorptive Heat Transformers (AHT). It presents a developed standard protocol for the complete characterization of advanced coated adsorbers. Providing an in-depth analysis of the different procedures necessary for evaluating the performance of adsorbers, it also presents an analysis of their stability under the hydrothermal and mechanical stresses during their entire life cycle. Adsorptive Heat Transformers (AHT), especially adsorption chillers and

  20. Control strategy research of variable flow at heat source side for water source heat pump%水源热泵系统热源侧变流量控制策略研究

    Institute of Scientific and Technical Information of China (English)

    蒋小强; 龙惟定; 李敏

    2012-01-01

    分析水源热泵系统供热运行的技术经济性.建立适用于TRNSYS软件模拟的水源热泵系统模型,针对不同水源温度通过改变热源侧水流量方式优化运行.比较水源热泵系统、燃气和燃油3种供热方式的运行经济性,结果表明,不同水源温度下的最佳供热方式不同.%Technical economy analysis of water source heat pump system is done in heating operation. The model of water source heat pump is established at TRNSYS platform, the optimal operation under different temperature of source water are carried by changing the water flow of heat source side. The running economy of heating by wate soure heat pump system, the combustion gas or oil is compared, the best heating mode is obtained at different water source temperature.

  1. Study of heat sources interacting in integrated circuits by laser mirage effect

    Energy Technology Data Exchange (ETDEWEB)

    Perpiñà, X.; Jordà, X.; Vellvehi, M. [Centre Nacional de Microelectrònica IMB-CNM (CSIC), Campus UAB, 08193 Bellaterra (Barcelona) (Spain); Altet, J. [Departament d' Enginyeria Electrònica, Universitat Politècnica de Catalunya, Barcelona 08034 (Spain)

    2014-08-25

    This work exploits the mirage effect to analyze multiple heat sources thermally interacting in an integrated circuit (IC) by means of a probe IR laser beam, which strikes on the die lateral walls and passes through the die substrate. Under such conditions, the criteria for locating such hot spots, as well as their relative power dissipation, are discussed on the basis of a theoretical model inferred in this work. Finally, the technique feasibility is shown in a real application scenario, obtaining 5-μm spatial lateral resolution and an error in power dissipation measurements below 5%. This method may become a practical alternative to usual off-chip techniques for inspecting hot spots in ICs and to experimentally characterize heat flow in the semiconductor substrate.

  2. Introduction of renewable energy sources in the district heating system of Greece

    Directory of Open Access Journals (Sweden)

    Nikolaos Margaritis

    2016-06-01

    Full Text Available The district heating (DH system of Greece, mainly supported from lignite fired stations, is facing lately significant challenges. Stricter emission limits, decreased efficiency due to old age and increased costs are major challenges of the lignite sector and are expected to result in the decommissioning of several lignite-fired units in the coming years. As a result, managers of DH networks are currently investigating alternative scenarios for the substitution of thermal power that it is expected to be lost, through the integration of Renewable Energy Sources (RES into the system. In this paper, the DH systems of Kozani and Ptolemaida are examined regarding possible introduction of RES. The first study examines district heating of Kozani and alternative future options for covering a part of city’s thermal load whereas the second study refers to a biomass CHP plant (ORC technology, 1MWe, 5MWth to be powered from a biomass mixture (wood chips and straw.

  3. In Situ Measurement of the Undisturbed Ground Temperature for Ground Source Heat Pump System

    Institute of Scientific and Technical Information of China (English)

    ZHOU Ya-su

    2008-01-01

    The undisturbed ground are important for design of the ground heat exchangers in ground source heat pump (GSHP) systems. In this paper, the undisturbed ground temperatures measured in two different methods are presented. The investigation was carried out in two cases. The temperature measured with the direct method is assumed to give the correct undisturbed ground temperature profile. The temperature measured with indirect method overestimates the undisturbed ground temperature by 2.1℃ and 1.7℃. This difference is mainly caused by the circulation pump and ambient air to the fluid. Therefore, the results that are decreased about 2℃ as compared with the indirect measured are recommended to estimate the undisturbed ground temperature in situ measuring. A smaller pump or deeper borehole or mild weather would result in a more correct temperature. Because the undisturbed ground temperature is affected by many factors. Whether or not these conclusions are correct to other areas, this would need further investigation.

  4. Second law analysis of advanced power generation systems using variable temperature heat sources

    Science.gov (United States)

    Bliem, C. J.; Mines, G. L.

    Many systems produce power using variable temperature (sensible) heat sources. The Heat Cycle Research Program is currently investigating the potential improvements to such power cycles utilizing moderate temperature geothermal resources to produce electrical power. It has been shown that mixtures of saturated hydrocarbons (alkanes) or halogenated hydrocarbons operating with a supercritical Rankine cycle gave improved performance over boiling Rankine cycles with the pure working fluids for typical applications. Recently, in addition to the supercritical Rankine Cycle, other types of cycles have been proposed for binary geothermal service. This paper explores the limits on efficiency of a feasible plant and discusses the methods used in these advanced concept plants to achieve the maximum possible efficiency. The advanced plants considered appear to be approaching the feasible limit of performance so that the designer must weigh all considerations to fine the best plant for a given service. These results would apply to power systems in other services as well as to geothermal power plants.

  5. Evaluation of geothermal energy as a heat source for the oilsands industry in Northern Alberta (Canada)

    Science.gov (United States)

    Majorowicz, J. A.; Unsworth, M.; Gray, A.; Nieuwenhuis, G.; Babadagli, T.; Walsh, N.; Weides, S.; Verveda, R.

    2012-12-01

    The extraction and processing of bitumen from the oilsands of Northern Alberta requires very large amounts of heat that is obtained by burning natural gas. At current levels, the gas used represents 6% of Canada's natural gas production. Geothermal energy could potentially provide this heat, thereby reducing both the financial costs and environmental impact of the oilsands industry. The Helmholtz Alberta Initiative is evaluating this application of geothermal energy through an integrated program of geology, geophysics, reservoir simulation and calculations of the cost benefit. A first stage in this evaluation is refining estimates of subsurface temperature beneath Northern Alberta. This has involved three stages: (1) Corrected industrial thermal data have been used to revise estimates of the upper crustal temperatures beneath the oilsands regions in Alberta. The geothermal gradient map produced using heat flow and thermal conductivity for the entire Phanerozoic column suggests that the overall gradient of the entire column is less than the gradients calculated directly from industry measurements. (2) Paleoclimatic corrections must be applied , since this region has experienced a significant increase in surface temperatures since the end of the last ice age causing a perturbation of shallow heat flow. For this reason, estimates of geothermal gradient based on shallow data are not necessarily characteristic of the whole sedimentary column and can lead to errors in temperature prediction at depth. (3) Improved measurements have been made of the thermal conductivity of the crystalline basement rocks (average = 2.9±0.8 W/m K). Thermal conductivity exhibits significant spatial variability and to a large degree controls the temperature conditions in the Precambrian crystalline basement rocks and its heat content at given heat flow-heat generation. When these steps are used to calculate subsurface temperatures, it can be shown that the temperatures required for geothermal

  6. Source Code Generator Based on Dynamic Frames

    Directory of Open Access Journals (Sweden)

    Danijel Radošević

    2011-06-01

    Full Text Available Normal 0 21 false false false HR X-NONE X-NONE MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Obična tablica"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0cm 5.4pt 0cm 5.4pt; mso-para-margin:0cm; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:"Times New Roman"; mso-bidi-theme-font:minor-bidi;} This paper presents the model of source code generator based on dynamic frames. The model is named as the SCT model because if its three basic components: Specification (S, which describes the application characteristics, Configuration (C, which describes the rules for building applications, and Templates (T, which refer to application building blocks. The process of code generation dynamically creates XML frames containing all building elements (S, C ant T until final code is produced. This approach is compared to existing XVCL frames based model for source code generating. The SCT model is described by both XML syntax and the appropriate graphical elements. The SCT model is aimed to build complete applications, not just skeletons. The main advantages of the presented model are its textual and graphic description, a fully configurable generator, and the reduced overhead of the generated source code. The presented SCT model is shown on development of web application example in order to demonstrate its features and justify our design choices.

  7. Plasma-based EUV light source

    Science.gov (United States)

    Shumlak, Uri; Golingo, Raymond; Nelson, Brian A.

    2010-11-02

    Various mechanisms are provided relating to plasma-based light source that may be used for lithography as well as other applications. For example, a device is disclosed for producing extreme ultraviolet (EUV) light based on a sheared plasma flow. The device can produce a plasma pinch that can last several orders of magnitude longer than what is typically sustained in a Z-pinch, thus enabling the device to provide more power output than what has been hitherto predicted in theory or attained in practice. Such power output may be used in a lithography system for manufacturing integrated circuits, enabling the use of EUV wavelengths on the order of about 13.5 nm. Lastly, the process of manufacturing such a plasma pinch is discussed, where the process includes providing a sheared flow of plasma in order to stabilize it for long periods of time.

  8. Improved heating efficiency with High-Intensity Focused Ultrasound using a new ultrasound source excitation.

    Science.gov (United States)

    Bigelow, Timothy A

    2009-01-01

    High-Intensity Focused Ultrasound (HIFU) is quickly becoming one of the best methods to thermally ablate tissue noninvasively. Unlike RF or Laser ablation, the tissue can be destroyed without inserting any probes into the body minimizing the risk of secondary complications such as infections. In this study, the heating efficiency of HIFU sources is improved by altering the excitation of the ultrasound source to take advantage of nonlinear propagation. For ultrasound, the phase velocity of the ultrasound wave depends on the amplitude of the wave resulting in the generation of higher harmonics. These higher harmonics are more efficiently converted into heat in the body due to the frequency dependence of the ultrasound absorption in tissue. In our study, the generation of the higher harmonics by nonlinear propagation is enhanced by transmitting an ultrasound wave with both the fundamental and a higher harmonic component included. Computer simulations demonstrated up to a 300% increase in temperature increase compared to transmitting at only the fundamental for the same acoustic power transmitted by the source.

  9. An experimental study of waveguide coupled microwave heating with conventional multicusp negative ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Komppula, J.; Kalvas, T.; Koivisto, H.; Laulainen, J.; Tarvainen, O.

    2015-04-08

    Negative ion production with conventional multicusp plasma chambers utilizing 2.45 GHz microwave heating is demonstrated. The experimental results were obtained with the multicusp plasma chambers and extraction systems of the RF-driven RADIS ion source and the filament driven arc discharge ion source LIISA. A waveguide microwave coupling system, which is almost similar to the one used with the SILHI ion source, was used. The results demonstrate that at least one third of negative ion beam obtained with inductive RF-coupling (RADIS) or arc discharge (LIISA) can be achieved with 1 kW of 2.45 GHz microwave power in CW mode without any modification of the plasma chamber. The co-extracted electron to H{sup −} ratio and the optimum pressure range were observed to be similar for both heating methods. The behaviour of the plasma implies that the energy transfer from the microwaves to the plasma electrons is mainly an off-resonance process.

  10. Synchrotron based spallation neutron source concepts

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Y.

    1998-07-01

    During the past 20 years, rapid-cycling synchrotrons (RCS) have been used very productively to generate short-pulse thermal neutron beams for neutron scattering research by materials science communities in Japan (KENS), the UK (ISIS) and the US (IPNS). The most powerful source in existence, ISIS in the UK, delivers a 160-kW proton beam to a neutron-generating target. Several recently proposed facilities require proton beams in the MW range to produce intense short-pulse neutron beams. In some proposals, a linear accelerator provides the beam power and an accumulator ring compresses the pulse length to the required {approx} 1 {micro}s. In others, RCS technology provides the bulk of the beam power and compresses the pulse length. Some synchrotron-based proposals achieve the desired beam power by combining two or more synchrotrons of the same energy, and others propose a combination of lower and higher energy synchrotrons. This paper presents the rationale for using RCS technology, and a discussion of the advantages and disadvantages of synchrotron-based spallation sources.

  11. Heating of thermoplastic-based unidirectional composite prepregs

    Energy Technology Data Exchange (ETDEWEB)

    Wang, X.; Weber, M.E.; Charrier, J.M. (McGill Univ., Montreal (Canada))

    1989-04-01

    Thermoplastic-based prepregs offer a potential for faster manufacture of composite products than with thermoset-based prepregs. The winding or controlled placement of thermoplastic-based prepreg tapes requires the rapid heating of the moving tape, just prior to its contact with the substrate on the mandrel. In the case of complex shapes, geometrical constraints and significant variations in tape speeds in the course of manufacture, make it particularly desirable to be able to model the heating process. A mathematical model and its experimental verification for convection/conduction heat transfer to and through either a homogeneous thermoplastic material, or thermoplastic-based unidirectional composites featuring glass, aramid and carbon fibers, is discussed. 12 refs.

  12. Micro- and Nanoscale Energetic Materials as Effective Heat Energy Sources for Enhanced Gas Generators.

    Science.gov (United States)

    Kim, Sang Beom; Kim, Kyung Ju; Cho, Myung Hoon; Kim, Ji Hoon; Kim, Kyung Tae; Kim, Soo Hyung

    2016-04-13

    In this study, we systematically investigated the effect of micro- and nanoscale energetic materials in formulations of aluminum microparticles (Al MPs; heat source)/aluminum nanoparticles (Al NPs; heat source)/copper oxide nanoparticles (CuO NPs; oxidizer) on the combustion and gas-generating properties of sodium azide microparticles (NaN3 MPs; gas-generating agent) for potential applications in gas generators. The burn rate of the NaN3 MP/CuO NP composite powder was only ∼0.3 m/s. However, the addition of Al MPs and Al NPs to the NaN3 MP/CuO NP matrix caused the rates to reach ∼1.5 and ∼5.3 m/s, respectively. In addition, the N2 gas volume flow rate generated by the ignition of the NaN3 MP/CuO NP composite powder was only ∼0.6 L/s, which was significantly increased to ∼1.4 and ∼3.9 L/s by adding Al MPs and Al NPs, respectively, to the NaN3 MP/CuO NP composite powder. This suggested that the highly reactive Al MPs and NPs, with the assistance of CuO NPs, were effective heat-generating sources enabling the complete thermal decomposition of NaN3 MPs upon ignition. Al NPs were more effective than Al MPs in the gas generators because of the increased reactivity induced by the reduced particle size. Finally, we successfully demonstrated that a homemade airbag with a specific volume of ∼140 mL could be rapidly and fully inflated by the thermal activation of nanoscale energetic material-added gas-generating agents (i.e., NaN3 MP/Al NP/CuO NP composites) within the standard time of ∼50 ms for airbag inflation.

  13. Effects of thermal radiation and heat transfer over an unsteady stretching surface embedded in a porous medium in the presence of heat source or sink

    Directory of Open Access Journals (Sweden)

    Elsayed M. A Elbashbeshy

    2011-01-01

    Full Text Available The effects of thermal radiation and heat transfer over an unsteady stretching surface embedded in a porous medium in the presence of heat source or sink are studied. The governing time dependent boundary layer equations are transformed to ordinary differential equations containing radiation parameter, permeability parameter, heat source or sink parameter, Prandtl number, and unsteadiness parameter. These equations are solved numerically by applying Nachtsheim-Swinger shooting iteration technique together with Rung-Kutta fourth order integration scheme. The velocity profiles, temperature profiles, the skin friction coefficient, and the rate of heat transfer are computed and discussed in details for various values of the different parameters. Comparison of the obtained numerical results is made with previously published results.

  14. FEM Simulation of Dissimilar Aluminum Titanium Fiber Laser Welding Using 2D and 3D Gaussian Heat Sources

    Directory of Open Access Journals (Sweden)

    Sonia D’Ostuni

    2017-08-01

    Full Text Available For a dissimilar laser weld, the model of the heat source is a paramount boundary condition for the prediction of the thermal phenomena, which occur during the welding cycle. In this paper, both two-dimensional (2D and three-dimensional (3D Gaussian heat sources were studied for the thermal analysis of the fiber laser welding of titanium and aluminum dissimilar butt joint. The models were calibrated comparing the fusion zone of the experiment with that of the numerical model. The actual temperature during the welding cycle was registered by a thermocouple and used for validation of the numerical model. When it came to calculate the fusion zone dimensions in the transversal section, the 2D heat source showed more accurate results. The 3D heat source provided better results for the simulated weld pool and cooling rate.

  15. Air-Source Integrated Heat Pump for Near-Zero Energy Houses: Technology Status Report

    Energy Technology Data Exchange (ETDEWEB)

    Murphy, Richard W [ORNL; Rice, C Keith [ORNL; Baxter, Van D [ORNL; Craddick, William G [ORNL

    2007-07-01

    This report documents the development of an air-source integrated heat pump (AS-IHP) through the third quarter of FY2007. It describes the design, analyses and testing of the AS-IHP, and provides performance specifications for a field test prototype and proposed control strategy. The results obtained so far continue to support the AS-IHP being a promising candidate to meet the energy service needs for DOE's development of a Zero Energy Home (ZEH) by the year 2020.

  16. Minimization of operator-balance interactive warmup by use of an alter ego heat source

    Science.gov (United States)

    Braudaway, D. W.

    Operator-equipment interaction is a well-known but frustrating part of many high precision measurements. Deterioration in performance of a high-precision balance required testing to identify the cause of the problem and to establish effectiveness of the solution. An unexpected result of the tests was a clear characterization of a significant operator-balance thermal interaction and verification of the empirically determined warmup requirement. The repeatability of the interactive effect inspired development of a replacement for the operator using an alter ego heat source.

  17. Monolithic fuel cell based power source for burst power generation

    Science.gov (United States)

    Fee, D. C.; Blackburn, P. E.; Busch, D. E.; Dees, D. W.; Dusek, J.; Easler, T. E.; Ellingson, W. A.; Flandermeyer, B. K.; Fousek, R. J.; Heiberger, J. J.

    A unique fuel cell coupled with a low power nuclear reactor presents an attractive approach for SDI burst power requirements. The monolithic fuel cell looks attractive for space applications and represents a quantum jump in fuel cell technology. Such a breakthrough in design is the enabling technology for lightweight, low volume power sources for space based pulse power systems. The monolith is unique among fuel cells in being an all solid state device. The capability for miniaturization, inherent in solid state devices, gives the low volume required for space missions. In addition, the solid oxide fuel cell technology employed in the monolith has high temperature reject heat and can be operated in either closed or open cycles. Both these features are attractive for integration into a burst power system.

  18. Effect of Thermo-Diffusion and Chemical Reaction on Mixed Convective Heat And Mass Transfer Through A Porous Medium In Cylindrical Annulus With Heat Source.

    Directory of Open Access Journals (Sweden)

    Dr.K.Gnaneswar

    2014-09-01

    Full Text Available A finite element study of combined heat and mass transfer flow through a porous medium in a circular cylindrical annulus with Soret and Dufour effects in the presence of heat sources has been analyzed. The coupled velocity, energy, and diffusion equations are solved numerically by using Galerkin- finite element technique. Shear stress, Nusslet number and Sherwood number are evaluated numerically for different values of the governing parameters under consideration and are shown in tabular form.

  19. The Influence of the Heat Source Temperature on the Multivane Expander Output Power in an Organic Rankine Cycle (ORC System

    Directory of Open Access Journals (Sweden)

    Piotr Kolasiński

    2015-04-01

    Full Text Available Organic Rankine Cycle (ORC power systems are nowadays an option for local and domestic cogeneration of heat and electric power. Very interesting are micropower systems for heat recovery from low potential (40–90 °C waste and renewable heat sources. Designing an ORC system dedicated to heat recovery from such a source is very difficult. Most important problems are connected with the selection of a suitable expander. Volumetric machines, such as scroll and screw expanders, are adopted as turbine alternative in small-power ORC systems. However, these machines are complicated and expensive. Vane expanders on the other hand are simple and cheap. This paper presents a theoretical and experimental analysis of the operation of a micro-ORC rotary vane expander under variable heat source temperature conditions. The main objective of this research was therefore a comprehensive analysis of relation between the vane expander output power and the heat source temperature. A series of experiments was performed using the micropower ORC test-stand. Results of these experiments are presented here, together with a mathematical description of multivane expanders. The analysis presented in this paper indicates that the output power of multivane expanders depend on the heat source temperature, and that multivane expanders are cheap alternatives to other expanders proposed for micropower ORC systems.

  20. Subscale Water Based Phase Change Material Heat Exchanger Development

    Science.gov (United States)

    Sheth, Rubik; Hansen, Scott

    2016-01-01

    Supplemental heat rejection devices are required in many spacecraft as the radiators are not sized to meet the full heat rejection demand. One means of obtaining additional heat rejection is through the use of phase change material heat exchangers (PCM HX's). PCM HX's utilize phase change to store energy in unfavorable thermal environments (melting) and reject the energy in favorable environments (freezing). Traditionally, wax has been used as a PCM on spacecraft. However, water is an attractive alternative because it is capable of storing about 40% more energy per unit mass due to its higher latent heat of fusion. The significant problem in using water as a PCM is its expansion while freezing, leading to structural integrity concerns when housed in an enclosed heat exchanger volume. Significant investigation and development has taken place over the past five years to understand and overcome the problems associated with water PCM HX's. This paper reports on the final efforts by Johnson Space Center's Thermal Systems Branch to develop a water based PCM HX. The test article developed and reported on is a subscale version of the full-scale water-based PCM HX's constructed by Mezzo Technologies. The subscale unit was designed by applying prior research on freeze front propagation and previous full-scale water PCM HX development. Design modifications to the subscale unit included use of urethane bladder, decreased aspect ratio, perforated protection sheet, and use of additional mid-plates. Testing of the subscale unit was successful and 150 cycles were completed without fail.

  1. Fuel rod model based on Non-Fourier heat conduction equation

    Energy Technology Data Exchange (ETDEWEB)

    Espinosa-Paredes, G. [Area de Ingenieria en Recursos Energeticos, Universidad Autonoma Metropolitana-Iztapalapa, Av. San Rafael Atlixco 186, Col. Vicentina, Mexico DF., CP 09340 (Mexico)], E-mail: gepe@xanum.uam.mx; Espinosa-Martinez, E-G. [Retorno Quebec 6, Col. Burgos de Cuernavaca 62580, Temixco, Mor. (Mexico)

    2009-05-15

    In this paper we explore the applicability of a fuel rod mathematical model based on Non-Fourier transient heat conduction as constitutive law for the Light Water Reactors transient analysis (LWRs). In the classical theory of diffusion, Fourier law of heat conduction is used to describe the relation between the heat flux vector and the temperature gradient assuming that the heat propagation speeds are infinite. The motivation for this research was to eliminate the paradox of an infinite thermal wave speed. The time-dependent heat sources were considered in the fuel rod heat transfer model. The close of the Main Steam Isolated Valves (MSIV) transient in a Boiling Water Reactor (BWR) was analyzed by different relaxation times. The results show that for long-times the heat fluxes on the clad surface under Non-Fourier approach can be important, while for short-times and from the engineering point of view the changes are very small. Some results from transient calculations are examined.

  2. Solar Water Heating as a Potential Source for Inland Norway Energy Mix

    Directory of Open Access Journals (Sweden)

    Dejene Assefa Hagos

    2014-01-01

    Full Text Available The aim of this paper is to assess solar potential and investigate the possibility of using solar water heating for residential application in Inland Norway. Solar potential based on observation and satellite-derived data for four typical populous locations has been assessed and used to estimate energy yield using two types of solar collectors for a technoeconomic performance comparison. Based on the results, solar energy use for water heating is competitive and viable even in low solar potential areas. In this study it was shown that a typical tubular collector in Inland Norway could supply 62% of annual water heating energy demand for a single residential household, while glazed flat plates of the same size were able to supply 48%. For a given energy demand in Inland Norway, tubular collectors are preferred to flat plate collectors for performance and cost reasons. This was shown by break-even capital cost for a series of collector specifications. Deployment of solar water heating in all detached dwellings in Inland could have the potential to save 182 GWh of electrical energy, equivalent to a reduction of 15,690 tonnes of oil energy and 48.6 ktCO2 emissions, and contributes greatly to Norway 67.5% renewable share target by 2020.

  3. X-ray Sources Generated from Gas-Filled Laser-Heated Targets

    Energy Technology Data Exchange (ETDEWEB)

    Back, C A; Grun, J; Decker, C D; Davis, J; Laming, J M; Feldman, U; Suter, L J; Landen, O L; Miller, M; Serduke, F; Wuest, C

    2000-06-06

    The X-ray sources in the 4-7 keV energy regime can be produced by laser-irradiating high-Z gas-filled targets with high-powered lasers. A series of experiments have been performed using underdense targets that are supersonically heated with {approx} 35 W of 0.35 {micro}m laser light. These targets were cylindrical Be enclosures that were filled with 1-2 atms of Xe gas. L-shell x-ray emission is emitted from the plasma and detected by Bragg crystal spectrometers and x-ray diodes. Absolute flux measurements show conversion efficiencies of {approx} 10% in the multi-kilovolt x-ray emission. These sources can be used as bright x-ray backlighters or for material testing.

  4. Magnetohydrodynamic 3D slip flow in a suspension of carbon nanotubes over a slendering sheet with heat source/sink

    Science.gov (United States)

    Kumar, R. V. M. S. S. Kiran; Varma, S. Vijaya Kumar; Raju, C. S. K.; Ibrahim, S. M.; Lorenzini, G.; Lorenzini, E.

    2017-05-01

    Carbon nanotubes are allotropes of carbon with a cylindrical nanostructure. These cylindrical carbon molecules have unusual properties, which are valuable for nanotechnology, electronics, optics and other fields of materials science and technology. With this intention, we investigate the three-dimensional magnetohydrodynamic convective heat and mass transfer of nanofluid over a slendering stretching sheet filled with porous medium and heat source/sink. For balancing the flow, temperature and concentration slip mechanisms are also taken into account. In this investigation simulation performed by mixing the two types of carbon nanotubes, namely single- and multi-walled carbon nanotubes, into water as base fluid. The governing system of partial differential equations is transformed into nonlinear ordinary differential equations which answered by using R-K-Fehlberg-integration scheme. The impact of various pertinent parameters on velocity, temperature and concentration as well as the friction factor coefficient, local Nusselt and local Sherwood number is derived and discussed through graphs and tables for both single- and multi-walled carbon nanotubes cases. It is found that the momentum boundary layer thickness of SWCNTs is thicker than MWCNTs. These results can help us to conclude that SWCNTs are helpful for minimizing the friction between the particles, whereas MWCNTs are helpful for boosting the heat and mass transfer rate.

  5. Solar water heating system for a lunar base

    Science.gov (United States)

    Somers, Richard E.; Haynes, R. Daniel

    1992-01-01

    An investigation of the feasibility of using a solar water heater for a lunar base is described. During the investigation, computer codes were developed to model the lunar base configuration, lunar orbit, and heating systems. Numerous collector geometries, orientation variations, and system options were identified and analyzed. The results indicate that the recommended solar water heater could provide 88 percent of the design load and would not require changes in the overall lunar base design. The system would give a 'safe-haven' water heating capability and use only 7 percent to 10 percent as much electricity as an electric heating system. As a result, a fixed position photovoltaic array can be reduced by 21 sq m.

  6. Preliminary analysis on the relationships between Tibetan Plateau NDVI change and its surface heat source and precipitation of China

    Institute of Scientific and Technical Information of China (English)

    HUA Wei; FAN GuangZhou; ZHOU DingWen; NI ChangJian; LI XueMin; WANG YongLi; LIU YaQin; HUANG XianLun

    2008-01-01

    Using the automatic weather station data obtained from the Tibetan Plateau (TP), the normalized dif-ference vegetation index and the monthly precipitation data of China and by the methods of correlation and composite analysis, preliminary analytical results are achieved concerning the relationships be-tween TP NDVI change and its surface heat source and precipitation of China. The results of our re-search may lead to the following conclusions: (1) A positive correlation relationship exists between TP NDVI change and its surface heat source, including the sensible heat and the latent heat. As to the correlation of the former, it is more remarkable in western TP than in eastern TP, and as to the correla-tion of the latter, however it turns out contrary. (2) With the improvement of TP vegetation, its surface heat source of every season is also mainly reinforced, especially in summer. As to the contribution of the sensible heat and the latent heat to the increment of the TP surface heat source intensity, the for-mer is comparatively more significant than the latter in winter and spring, while in summer and autumn, the two have almost the same importance. (3) The correlation coefficient between summer NDVI over TP and the corresponding period precipitation of China displays a belt distribution of "+-+" from south to north China. (4) Anomalous surface heating field over TP derived from vegetation change is probably an important factor to affect summer precipitation of China.keywords Tibetan Plateau, vegetation change, surface heat source, precipitation of China.

  7. Phase Change Material Based Accumulation Panels in Combination with Renewable Energy Sources and Thermoelectric Cooling

    Directory of Open Access Journals (Sweden)

    Jan Skovajsa

    2017-01-01

    Full Text Available The article deals with the use of modern materials and technologies that can improve the thermal comfort in buildings. The article describes the design and usage of a special accumulation device, which is composed of thermal panels based on phase change materials (PCMs. The thermal panels have an integrated tube heat exchanger and heating foils. The technology can be used as a passive or active system for heating and cooling. It is designed as a “green technology”, so it is able to use renewable energy sources, e.g., photovoltaic (PV panels, solar thermal collectors and heat pumps. Moreover, an interesting possibility is the ability to use thermoelectric coolers. In the research, measurements of the different operating modes were made, and the results are presented in the text. The measurement approves that the technology improves the thermal capacity of the building, and it is possible to use it for active heating and cooling.

  8. Hybrid Ground-Source Heat Pump Installations: Experiences, Improvements, and Tools

    Energy Technology Data Exchange (ETDEWEB)

    Scott Hackel; Amanda Pertzborn

    2011-06-30

    One innovation to ground-source heat pump (GSHP, or GHP) systems is the hybrid GSHP (HyGSHP) system, which can dramatically decrease the first cost of GSHP systems by using conventional technology (such as a cooling tower or a boiler) to meet a portion of the peak heating or cooling load. This work uses three case studies (two cooling-dominated, one heating-dominated) to demonstrate the performance of the hybrid approach. Three buildings were studied for a year; the measured data was used to validate models of each system. The models were used to analyze further improvements to the hybrid approach, and establish that this approach has positive impacts, both economically and environmentally. Lessons learned by those who design and operate the systems are also documented, including discussions of equipment sizing, pump operation, and cooling tower control. Finally, the measured data sets and models that were created during this work are described; these materials have been made freely available for further study of hybrid systems.

  9. Methionine sources do not affect performance and carcass yield of broilers fed vegetable diets and aubmitted to cyclic heat stress

    Directory of Open Access Journals (Sweden)

    AML Ribeiro

    2005-09-01

    Full Text Available The supplementation of vegetal diets with L-methionine (100% molar, methionine hydroxyl analogue (HMB (88% molar or DL-methionine (99% molar was compared as to the performance of broilers allocated in cages and submitted to cyclic heat stress (CHS. The trial was carried out from 21 to 42 days of age. Two levels of synthetic methionine were supplemented for each methionine source (0.1 or 0.3 %, and the control treatment was not supplemented with synthetic methionine (negative control. Statistical analyses included the negative control treatment or were performed in a 3 x 2 factorial design (sources x levels. Addition of synthetic methionine to the basal level containing 0.63 % of total sulphur amino acids significantly improved feed conversion (FC independent of the source. On the other hand, improvements in weight gain (WG and body weight (BW were more consistent comparing the negative control to HMB-supplemented treatments. Factorial analysis showed better FC for L-Met compared to DL-Met, whereas HMB showed intermediate results. The supplementation level of 0.3% methionine showed better FC than 0.1%. Methionine levels or sources had no effects on carcass, yields of cuts or feathering results. Therefore, results of DL-Met and HMB added to vegetal-based diets in comparable molar terms promoted similar performance in broilers under CHS conditions.

  10. Heat Transfer by Thermo-capillary Convection -Sounding Rocket COMPERE Experiment SOURCE

    Science.gov (United States)

    Dreyer, Michael; Fuhrmann, Eckart

    The sounding rocket COMPERE experiment SOURCE was successfully flown on MASER 11, launched in Kiruna (ESRANGE), May 15th, 2008. SOURCE has been intended to partly ful-fill the scientific objectives of the European Space Agency (ESA) Microgravity Applications Program (MAP) project AO-2004-111 (Convective boiling and condensation). Three parties of principle investigators have been involved to design the experiment set-up: ZARM for thermo-capillary flows, IMFT (Toulouse, France) for boiling studies, EADS Astrium (Bremen, Ger-many) for depressurization. The topic of this paper is to study the effect of wall heat flux on the contact line of the free liquid surface and to obtain a correlation for a convective heat trans-fer coefficient. The experiment has been conducted along a predefined time line. A preheating sequence at ground was the first operation to achieve a well defined temperature evolution within the test cell and its environment inside the rocket. Nearly one minute after launch, the pressurized test cell was filled with the test liquid HFE-7000 until a certain fill level was reached. Then the free surface could be observed for 120 s without distortion. Afterwards, the first depressurization was started to induce subcooled boiling, the second one to start saturated boiling. The data from the flight consists of video images and temperature measurements in the liquid, the solid, and the gaseous phase. Data analysis provides the surface shape versus time and the corresponding apparent contact angle. Computational analysis provides information for the determination of the heat transfer coefficient in a compensated gravity environment where a flow is caused by the temperature difference between the hot wall and the cold liquid. The paper will deliver correlations for the effective contact angle and the heat transfer coefficient as a function of the relevant dimensionsless parameters as well as physical explanations for the observed behavior. The data will be used

  11. Characterization of Site for Installing Open Loop Ground Source Heat Pump System

    Science.gov (United States)

    Yun, S. W.; Park, Y.; Lee, J. Y.; Yi, M. J.; Cha, J. H.

    2014-12-01

    This study was conducted to understand hydrogeological properties of site where open loop ground source heat pump system will be installed and operated. Groundwater level and water temperature were hourly measured at the well developed for usage of open loop ground source heat pump system from 11 October 2013 to 8 January 2014. Groundwater was sampled in January and August 2013 and its chemical and isotopic compositions were analyzed. The bedrock of study area is the Jurassic granodiorite that mainly consists of quartz (27.9 to 46.8%), plagioclase (26.0 to 45.5%), and alkali feldspar (9.5 to 18.7%). The groundwater level ranged from 68.30 to 68.94 m (above mean sea level). Recharge rate was estimated using modified watertable fluctuation method and the recharge ratios was 9.1%. The water temperature ranged from 14.8 to 15.0oC. The vertical Increase rates of water temperature were 1.91 to 1.94/100 m. The water temperature showed the significant seasonal variation above 50 m depth, but had constant value below 50 m depth. Therefore, heat energy of the groundwater can be used securely in open loop ground source heat pump system. Electrical conductivity ranged from 120 to 320 µS/cm in dry season and from 133 to 310 µS/cm in wet season. The electrical conductivity gradually decreased with depth. In particular, electrical conductivity in approximately 30 m depth decreased dramatically (287 to 249 µS/cm) in wet season. The groundwater was Ca-HCO3 type. The concentrations of dissolved components did not show the vertically significant variations from 0 to 250 m depth. The δ18O and δD ranged from -9.5 to -9.4‰ and from -69 to -68‰. This work is supported by the New and Renewable Energy of the Korea Institute of Energy Technology Evaluation and Planning (KETEP) grant funded by the Korea government Ministry of Knowledge Economy (No.20123040110010).

  12. ELF/VLF wave generation from the beating of two HF ionospheric heating sources

    Science.gov (United States)

    Cohen, M. B.; Moore, R. C.; Golkowski, M.; Lehtinen, N. G.

    2012-12-01

    It is well established that Extremely Low Frequency (ELF, 0.3-3 kHz) and Very Low Frequency (VLF, 3-30 kHz) radio waves can be generated via modulated High Frequency (HF, 3-10 MHz) heating of the lower ionosphere (60-100 km). The ionospheric absorption of HF power modifies the conductivity of the lower ionosphere, which in the presence of natural currents such as the auroral electrojet, creates an `antenna in the sky.' We utilize a theoretical model of the HF to ELF/VLF conversion and the ELF/VLF propagation, and calculate the amplitudes of the generated ELF/VLF waves when two HF heating waves, separated by the ELF/VLF frequency, are transmitted from two adjacent locations. The resulting ELF/VLF radiation pattern exhibits a strong directional dependence (as much as 15 dB) that depends on the physical spacing of the two HF sources. This beat wave source can produce signals 10-20 dB stronger than those generated using amplitude modulation, particularly for frequencies greater than 5-10 kHz. We evaluate recent suggestions that beating two HF waves generates ELF/VLF waves in the F-region (>150 km), and conclude that those experimental results may have misinterpreted, and can be explained strictly by the much more well established D region mechanism.

  13. Mixed convection flow with non-uniform heat source/sink in a doubly stratified magnetonanofluid

    Science.gov (United States)

    Mehmood, K.; Hussain, S.; Sagheer, M.

    2016-06-01

    In this study, we explore the unsteady flow of viscous nanofluid driven by an inclined stretching sheet. The novelty of the present study is to account for the effect of a non-uniform heat source/sink in a thermally and solutally stratified magnetonanofluid. Governing system of nonlinear partial differential equations is converted into a system of nonlinear ordinary differential equations. Solution of the transformed system is obtained using RK4 method with shooting technique. It is observed that increase in the values of thermal and mass stratification parameter reduce the velocity profile and increase in the values of variable thermal conductivity parameter and non-uniform heat source/sink parameters enhance the temperature distribution. Moreover, skin friction coefficient, Nusselt number and Sherwood number are discussed. Obtained results are displayed both graphically and in tabular form to illustrate the effect of different parameters on the velocity, temperature and concentration profiles. Numerical results are compared with previous published results and found to be in good agreement for special cases of the emerging parameters.

  14. A comparative assessment of future heat and power sources for the UK domestic sector

    Energy Technology Data Exchange (ETDEWEB)

    Cockroft, Jeremy; Kelly, Nick [Energy Systems Research Unit, Department of Mechanical Engineering, 75 Montrose Street, University of Strathclyde, Glasgow G1 1XJ (United Kingdom)

    2006-09-15

    In 2003, the UK government announced its aspiration for a 60% reduction in CO{sub 2} emissions by 2050 relative to 1990 levels. To achieve this radical target, action is required across all sectors of the economy to reduce energy demand significantly and to increase the supply of energy from zero or low carbon sources. Focusing on the domestic sector, where energy consumption is currently rising, technologies such as fuel cells, Stirling and internal combustion engine micro-CHP and heat pumps are often cited as the means to reduce carbon emissions. However, there is much uncertainty as to the potential environmental benefits (if any) of the aforementioned technologies when set against a picture of changing energy supply and demand. The paper describes an analysis in which the performance of the four different technologies mentioned above was compared against a common datum of energy supply from condensing gas boilers and grid electricity for a number of scenarios. The aim of the analysis was to determine if significant CO{sub 2} savings could be made and to determine the minimum thermodynamic performance criteria that these technologies must attain if they are to yield any environmental benefits. The main finding of the work is that air source heat pumps yield significantly more CO{sub 2} savings than any of the other technologies examined. (author)

  15. Clinical applications of internal heat source analysis for breast cancer identification.

    Science.gov (United States)

    Han, F; Liang, C W; Shi, G L; Wang, L; Li, K Y

    2015-02-13

    Nondestructive preoperative breast imaging techniques are widely used for breast cancer testing and diagnosis. This study aimed to evaluate the feasibility and efficacy of quantitative diagnosis via the thermal analysis of abnormal metabolism. Nine hundred forty-eight women who underwent breast biopsy from 2009 to 2013 were investigated. Thermal analysis was used to calculate the internal heat source (i.e., tumor) thermal power for each participant. The applicability and effectiveness of our approach were estimated using the chi-square test, kappa statistics (k), and odds ratios (OR). Breast density and tumor size were considered during this estimation. A thermal power q = 0.2 w was determined as the optimal separation threshold between breast cancer and benign disease. Moreover, good agreement (k = 0.837) with the gold-standard assessment (breast biopsy) was confirmed in 93.2% of the patients (N = 884/948), and the sensitivity and specificity were 94.2 and 92.9%, respectively. The results also found no significant differences in methodological accuracy between the fatty and dense breasts (OR = 1.194, P = 0.524). Furthermore, after dividing the cohort into three groups according to tumor size (T1: 5 cm), the tumor size had no effect on the proposed method (ORs = 1, P = 0.724). Internal heat source analysis can feasibly and efficiently distinguish between breast cancer and benign disease.

  16. Flow characteristics of the raw sewage for the design of sewage-source heat pump systems.

    Science.gov (United States)

    Xu, Ying; Wu, Yuebin; Sun, Qiang

    2014-01-01

    The flow characteristics of raw sewage directly affect the technical and economic performance of sewage-source heat pump systems. The purpose of this research is to characterize the flow characteristics of sewage by experimental means. A sophisticated and flexible experimental apparatus was designed and constructed. Then the flow characteristics of the raw sewage were studied through laboratorial testing and theoretical analyses. Results indicated that raw sewage could be characterized as a power-law fluid with the rheological exponent n being 0.891 and the rheological coefficient k being 0.00175. In addition, the frictional loss factor formula in laminar flow for raw sewage was deduced by theoretical analysis of the power-law fluid. Furthermore, an explicit empirical formula for the frictional loss factor in turbulent flow was obtained through curve fitting of the experimental data. Finally, the equivalent viscosity of the raw sewage is defined in order to calculate the Reynolds number in turbulent flow regions; it was found that sewage had two to three times the viscosity of water at the same temperature. These results contributed to appropriate parameters of fluid properties when designing and operating sewage-source heat pump systems.

  17. Production of 238PuO2 heat sources for the Cassini mission

    Science.gov (United States)

    George, Timothy G.; Foltyn, Elizabeth M.

    1998-01-01

    NASA's Cassini mission to Saturn, scheduled to launch in October, 1997, is perhaps the most ambitious interplanetary explorer ever constructed. Electric power for the spacecraft's science instruments and on-board computers will be provided by three radioisotope thermoelectric generators (RTGs) powered by 216 238PuO2-fueled General-Purpose Heat Source (GPHS) capsules. In addition, critical equipment and instruments on the spacecraft and Huygens probe will be warmed by 128 Light-Weight Radioisotope Heater Units (LWRHUs). Fabrication and assembly of the GPHS capsules and LWRHU heat sources was performed at Los Alamos National Laboratory (LANL) between January 1994 and September 1996. During this production campaign, LANL pressed and sintered 315 GPHS fuel pellets and 181 LWRHU pellets. By October 1996, NMT-9 had delivered a total of 235 GPHS capsules to EG&G Mound Applied Technologies (EG&G MAT) in Miamisburg, Ohio. EG&G MAT conditioned the capsules for use, loaded the capsules into the Cassini RTGs, tested the RTGs, and coordinated transportation to Kennedy Space Center (KSC). LANL also fabricated and assembled a total of 180 LWRHUs. The LWRHUs required for the Cassini spacecraft were shipped to KSC in mid-1997.

  18. General-Purpose Heat Source Development: Safety Test Program. Postimpact evaluation, Design Iteration Test 3

    Energy Technology Data Exchange (ETDEWEB)

    Schonfeld, F.W.; George, T.G.

    1984-07-01

    The General-Purpose Heat Source(GPHS) provides power for space missions by transmitting the heat of /sup 238/PuO/sub 2/ decay to thermoelectric elements. Because of the inevitable return of certain aborted missions, the heat source must be designed and constructed to survive both re-entry and Earth impact. The Design Iteration Test (DIT) series is part of an ongoing test program. In the third test (DIT-3), a full GPHS module was impacted at 58 m/s and 930/sup 0/C. The module impacted the target at an angle of 30/sup 0/ to the pole of the large faces. The four capsules used in DIT-3 survived impact with minimal deformation; no internal cracks other than in the regions indicated by Savannah River Plant (SRP) preimpact nondestructive testing were observed in any of the capsules. The 30/sup 0/ impact orientation used in DIT-3 was considerably less severe than the flat-on impact utilized in DIT-1 and DIT-2. The four capsules used in DIT-1 survived, while two of the capsules used in DIT-2 breached; a small quantity (approx. = 50 ..mu..g) of /sup 238/PuO/sub 2/ was released from the capsules breached in the DIT-2 impact. All of the capsules used in DIT-1 and DIT-2 were severely deformed and contained large internal cracks. Postimpact analyses of the DIT-3 test components are described, with emphasis on weld structure and the behavior of defects identified by SRP nondestructive testing.

  19. Thermal stresses induced by a point heat source in a circular plate by quasi-static approach

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    The present paper deals with the determination of quasi-static thermal stresses due to an instantaneous point heat source of strength g_(pi) situated at certain circle along the radial direction of the circular plate and releasing its heat spontaneously at time t=τ.A circular plate is considered having arbitrary initial temperature and subjected to time dependent heat flux at the fixed circular boundary of r=b.The governing heat conduction equation is solved by using the integral transform method,and res...

  20. Numerical simulations of the impact of seasonal heat storage on source zone emission in a TCE contaminated aquifer

    Science.gov (United States)

    Popp, Steffi; Beyer, Christof; Dahmke, Andreas; Bauer, Sebastian

    2016-04-01

    In urban regions, with high population densities and heat demand, seasonal high temperature heat storage in the shallow subsurface represents an attractive and efficient option for a sustainable heat supply. In fact, the major fraction of energy consumed in German households is used for room heating and hot water production. Especially in urbanized areas, however, the installation of high temperature heat storage systems is currently restricted due to concerns on negative influences on groundwater quality caused e.g. by possible interactions between heat storages and subsurface contaminants, which are a common problem in the urban subsurface. Detailed studies on the overall impact of the operation of high temperature heat storages on groundwater quality are scarce. Therefore, this work investigates possible interactions between groundwater temperature changes induced by heat storage via borehole heat exchangers and subsurface contaminations by numerical scenario analysis. For the simulation of non-isothermal groundwater flow, and reactive transport processes the OpenGeoSys code is used. A 2D horizontal cross section of a shallow groundwater aquifer is assumed in the simulated scenario, consisting of a sandy sediment typical for Northern Germany. Within the aquifer a residual trichloroethene (TCE) contaminant source zone is present. Temperature changes are induced by a seasonal heat storage placed within the aquifer with scenarios of maximum temperatures of 20°C, 40°C and 60°C, respectively, during heat injection and minimum temperatures of 2°C during heat extraction. In the scenario analysis also the location of the heat storage relative to the TCE source zone and plume was modified. Simulations were performed in a homogeneous aquifer as well as in a set of heterogeneous aquifers with hydraulic conductivity as spatially correlated random fields. In both cases, results show that the temperature increase in the heat plume and the consequential reduction of water

  1. A helium based pulsating heat pipe for superconducting magnets

    Science.gov (United States)

    Fonseca, Luis Diego; Miller, Franklin; Pfotenhauer, John

    2014-01-01

    This study was inspired to investigate an alternative cooling system using a helium-based pulsating heat pipes (PHP), for low temperature superconducting magnets. In addition, the same approach can be used for exploring other low temperature applications. The advantages of PHP for transferring heat and smoothing temperature profiles in various room temperature applications have been explored for the past 20 years. An experimental apparatus has been designed, fabricated and operated and is primarily composed of an evaporator and a condenser; in which both are thermally connected by a closed loop capillary tubing. The main goal is to measure the heat transfer properties of this device using helium as the working fluid. The evaporator end of the PHP is comprised of a copper winding in which heat loads up to 10 watts are generated, while the condenser is isothermal and can reach 4.2 K via a two stage Sumitomo RDK408A2 GM cryocooler. Various experimental design features are highlighted. Additionally, performance results in the form of heat transfer and temperature characteristics are provided as a function of average condenser temperature, PHP fill ratio, and evaporator heat load. Results are summarized in the form of a dimensionless correlation and compared to room temperature systems. Implications for superconducting magnet stability are highlighted.

  2. Trellis-based source and channel coding

    NARCIS (Netherlands)

    Van der Vleuten, R.J.

    1994-01-01

    This thesis concerns the efficient transmission of digital data, such as digitized sounds or images, from a source to its destination. To make the best use of the limited capacity of the source-destination channel, a source coder is used to delete the less significant information. To correct the occ

  3. Design Optimization and the Limits of Steady-State Heating Efficiency for Conventional Single-Speed Air-Source Heat Pumps

    Energy Technology Data Exchange (ETDEWEB)

    Rice, C.K.

    2001-06-06

    The ORNL Heat Pump Model and an optimizing program were used to explore the limits of steady-state heating efficiency for conventional air-source heat pumps. The method used allows for the simultaneous optimization of ten selected design variables, taking proper account of their interactions, while constraining other parameters to chosen limits or fixed values. Designs were optimized for a fixed heating capacity, but the results may be scaled to other capacities. Substantial performance improvement is predicted compared to today's state of the art heat pump. With increased component efficiencies that are expected in the near future and with modest increases in heat exchanger area, a 28% increase in heating efficiency is predicted; for long-term improvements with considerably larger heat exchangers, a 56% increase is possible. The improved efficiencies are accompanied by substantial reductions in the requirements for compressor and motor size. The predicted performance improvements are attributed not only to improved components and larger heat exchangers but also to the use of an optimizing design procedure. Deviations from the optimized design may be necessary to make use of available component sizes and to maintain good cooling-mode performance while improving the heating efficiency. Sensitivity plots (i.e., COP as a function of one or more design parameters) were developed to explore design flexibilities and to evaluate their consequences. The performance of the optimized designs was compared to that of modified ideal cycles to assess the factors that limit further improvement. It is hoped that the design methods developed will be useful to designers in the heat pump industry.

  4. Influence of Heat Sources and Relaxation Time on Temperature Distribution in Tissues

    Directory of Open Access Journals (Sweden)

    Sharma S.

    2014-05-01

    Full Text Available In the present study, the temperature fluctuations in tissues based on Penne’s bio-heat transfer equation is investigated by applying the Laplace and Hankel transforms. To get the solution in a physical form, a numerical inversion technique has been applied. The temporal and spatial distribution of temperature is investigated with the effect of relaxation time and is presented graphically.

  5. 地源热泵能效比试验与研究%Source Heat Pump Energy Efficiency Ratio Experiments and Studies

    Institute of Scientific and Technical Information of China (English)

    郭彬; 刘林; 王劲松; 季家艳; 张圣勇

    2014-01-01

    We used to test different models of well pipe to the cooling capacity, heat transfer capability of further study the impact of ground source heat pump. Ground source heat pump energy efficiency ratio of prospects for a brief introduction, the test part through the sensor calibration and error analysis, to ensure the accuracy of experimental test data, cooling, thermal test and test taking, as applied heat transfer model, based on heat and get hot water flow in the pipe flow and temperature, horizontal tube can be calculated in a variety of conditions, the average cooling and heating capacity to take in view of the ground source heat pump applications, the ground heat exchanger design is the most critical part, while the energy efficiency of ground source heat pump is closely linked with another, to know the different types of wells can be buried on the energy efficiency of ground source heat pump.%采用对比试验,对不同型号井埋管的散热能力、传热能力进行研究,从而得出不同井埋管对地源热泵的不同影响。对地源热泵能效比研究前景作简单介绍,在试验部分,通过对传感器进行校正与误差分析,保证试验中数据的精确性,使散热试验和取热试验一样。应用传热模型,根据散热和取热中管内水流的流量和温度,就可以计算出水平管在各种工况下的平均散热和取热能力,鉴于在地源热泵系统应用中,地埋管换热器的设计是最关键的部分,而地源热泵的能效比又与其有密切联系,可以由此知道不同型号井埋管对地源热泵能效比的影响。

  6. X-RAY SOURCE HEIGHTS IN A SOLAR FLARE: THICK-TARGET VERSUS THERMAL CONDUCTION FRONT HEATING

    Energy Technology Data Exchange (ETDEWEB)

    Reep, J. W. [National Research Council Post-Doc Program, Naval Research Laboratory, Washington, DC 20375 (United States); Bradshaw, S. J. [Department of Physics and Astronomy, Rice University, Houston, TX 77005 (United States); Holman, G. D., E-mail: jeffrey.reep.ctr@nrl.navy.mil, E-mail: stephen.bradshaw@rice.edu, E-mail: gordon.d.holman@nasa.gov [Solar Physics Laboratory, Code 671, NASA Goddard Space Flight Center, Greenbelt, MD 20771 (United States)

    2016-02-10

    Observations of solar flares with RHESSI have shown X-ray sources traveling along flaring loops, from the corona down to the chromosphere and back up. The 2002 November 28 C1.1 flare, first observed with RHESSI by Sui et al. and quantitatively analyzed by O’Flannagain et al., very clearly shows this behavior. By employing numerical experiments, we use these observations of X-ray source height motions as a constraint to distinguish between heating due to a non-thermal electron beam and in situ energy deposition in the corona. We find that both heating scenarios can reproduce the observed light curves, but our results favor non-thermal heating. In situ heating is inconsistent with the observed X-ray source morphology and always gives a height dispersion with photon energy opposite to what is observed.

  7. X-ray Source Heights in a Solar Flare: Thick-target versus Thermal Conduction Front Heating

    CERN Document Server

    Reep, Jeffrey W; Holman, Gordon D

    2015-01-01

    Observations of solar flares with RHESSI have shown X-ray sources traveling along flaring loops, from the corona down to the chromosphere and back up. The 28 November 2002 C1.1 flare, first observed with RHESSI by Sui et al. 2006 and quantitatively analyzed by O'Flannagain et al. 2013, very clearly shows this behavior. By employing numerical experiments, we use these observations of X-ray source height motions as a constraint to distinguish between heating due to a non-thermal electron beam and in situ energy deposition in the corona. We find that both heating scenarios can reproduce the observed light curves, but our results favor non-thermal heating. In situ heating is inconsistent with the observed X-ray source morphology and always gives a height dispersion with photon energy opposite to what is observed.

  8. Ion source based on the cathodic arc

    Science.gov (United States)

    Sanders, David M.; Falabella, Steven

    1994-01-01

    A cylindrically symmetric arc source to produce a ring of ions which leave the surface of the arc target radially and are reflected by electrostatic fields present in the source to a point of use, such as a part to be coated. An array of electrically isolated rings positioned in the source serves the dual purpose of minimizing bouncing of macroparticles and providing electrical insulation to maximize the electric field gradients within the source. The source also includes a series of baffles which function as a filtering or trapping mechanism for any macroparticles.

  9. An MHD Heat Source Based on Intermetallic Reactions

    Science.gov (United States)

    2007-11-02

    02 —> Ti02 + B203 + 6.42 kcal/g. Figure A.3 shows typical DTA (Differential Thermal Analysis) and TGA (Thermogravimetric Analysis) response. At 928... Ti02 and B203. The weight increases as noted of 91% and 88% compare favorably with the theoretical increase of 115%. The ratio of the area under the...TOTiB, FORMATION 2ND EXOTHERM DUETOTiB2 COMBUSTION ( Ti02 & B203) TOTAL ENERGY RELEASED 6.2 kcal/g (82% THEORETICAL) TIME FIGURE A.3. TWO

  10. Diamond-based heat spreaders for power electronic packaging applications

    Science.gov (United States)

    Guillemet, Thomas

    As any semiconductor-based devices, power electronic packages are driven by the constant increase of operating speed (higher frequency), integration level (higher power), and decrease in feature size (higher packing density). Although research and innovation efforts have kept these trends continuous for now more than fifty years, the electronic packaging technology is currently facing a challenge that must be addressed in order to move toward any further improvements in terms of performances or miniaturization: thermal management. Thermal issues in high-power packages strongly affect their reliability and lifetime and have now become one of the major limiting factors of power modules development. Thus, there is a strong need for materials that can sustain higher heat flux levels while safely integrating into the electronic package architecture. In such context, diamond is an attractive candidate because of its outstanding thermal conductivity, low thermal expansion, and high electrical resistivity. Its low heat capacity relative to metals such as aluminum or copper makes it however preferable for heat spreading applications (as a heat-spreader) rather than for dissipating the heat flux itself (as a heat sink). In this study, a dual diamond-based heat-spreading solution is proposed. Polycrystalline diamond films were grown through laser-assisted combustion synthesis on electronic substrates (in the U.S) while, in parallel, diamond-reinforced copper-matrix composite films were fabricated through tape casting and hot pressing (in France). These two types of diamond-based heat-spreading films were characterized and their microstructure and chemical composition were related to their thermal performances. Particular emphasize was put on the influence of interfaces on the thermal properties of the materials, either inside a single material (grain boundaries) or between dissimilar materials (film/substrate interface, matrix/reinforcement interface). Finally, the packaging

  11. Earliest Deadline Control of a Group of Heat Pumps with a Single Energy Source

    NARCIS (Netherlands)

    Fink, J.; van Leeuwen, Richard Pieter

    2016-01-01

    In this paper, we develop and investigate the optimal control of a group of 104 heat pumps and a central Combined Heat and Power unit (CHP). The heat pumps supply space heating and domestic hot water to households. Each house has a buffer for domestic hot water and a floor heating system for space h

  12. Earliest Deadline Control of a Group of Heat Pumps with a Single Energy Source

    NARCIS (Netherlands)

    Fink, J.; van Leeuwen, Richard Pieter

    2016-01-01

    In this paper, we develop and investigate the optimal control of a group of 104 heat pumps and a central Combined Heat and Power unit (CHP). The heat pumps supply space heating and domestic hot water to households. Each house has a buffer for domestic hot water and a floor heating system for space

  13. Prediction of heat transfer of nanofluid on critical heat flux based on fractal geometry

    Institute of Scientific and Technical Information of China (English)

    Xiao Bo-Qi

    2013-01-01

    Analytical expressions for nucleate pool boiling heat transfer of nanofluid in the critical heat flux (CHF) region are derived taking into account the effect of nanoparticles moving in liquid based on the fractal geometry theory.The proposed fractal model for the CHF of nanofluid is explicitly related to the average diameter of the nanoparticles,the volumetric nanoparticle concentration,the thermal conductivity of nanoparticles,the fractal dimension of nanoparticles,the fractal dimension of active cavities on the heated surfaces,the temperature,and the properties of the fluid.It is found that the CHF of nanofluid decreases with the increase of the average diameter of nanoparticles.Each parameter of the proposed formulas on CHF has a clear physical meaning.The model predictions are compared with the existing experimental data,and a good agreement between the model predictions and experimental data is found.The validity of the present model is thus verified.The proposed fractal model can reveal the mechanism of heat transfer in nanofluid.

  14. Convective heat and mass transfer in three-dimensional mixed convection flow of viscoelastic fluid in presence of chemical reaction and heat source/sink

    Science.gov (United States)

    Bilal Ashraf, M.; Alsaedi, A.; Hayat, T.; Shehzad, S. A.

    2017-06-01

    Heat and mass transfer effects in the three-dimensional mixed convection flow of a viscoelastic fluid with internal heat source/sink and chemical reaction have been investigated in the present work. The flow generation is because of an exponentially stretching surface. Magnetic field normal to the direction of flow is considered. Convective conditions at the surface are also encountered. Appropriate similarity transformations are utilized to reduce the boundary layer partial differential equations into the ordinary differential equations. The homotopy analysis method is used to develop the solution expressions. Impacts of different controlling parameters such as ratio parameter, Hartman number, internal heat source/sink, chemical reaction, mixed convection, concentration buoyancy parameter and Biot numbers on the velocity, temperature and concentration profiles are analyzed. The local Nusselt and Sherwood numbers are sketched and examined.

  15. Experimental Optimization of Passive Cooling of a Heat Source Array Flush-Mounted on a Vertical Plate

    Directory of Open Access Journals (Sweden)

    Antoine Baudoin

    2016-11-01

    Full Text Available Heat sources, such as power electronics for offshore power, could be cooled passively—mainly by conduction and natural convection. The obvious advantage of this strategy is its high reliability. However, it must be implemented in an efficient manner (i.e., the area needs to be kept low to limit the construction costs. In this study, the placement of multiple heat sources mounted on a vertical plate was studied experimentally for optimization purposes. We chose a regular distribution, as this is likely to be the preferred choice in the construction process. We found that optimal spacing can be determined for a targeted source density by tuning the vertical and horizontal spacing between the heat sources. The optimal aspect ratio was estimated to be around two.

  16. Simulation and optimisation of a ground source heat pump with different ground heat exchanger configurations for a single-family residential house

    DEFF Research Database (Denmark)

    Pavlov, Georgi Krasimiroy; Olesen, Bjarne W.

    2012-01-01

    In the future there will be an increased demand for energy efficient cooling of residential buildings. Therefore it is essential to develop cooling concepts that are passive and/or using very little primary energy. A possible solution is a ground source heat pump combined with a low....... For the studied geographical location, passive cooling by bypassing the heat pump and using only the ground heat exchanger can provide acceptable room temperatures.......-temperature heating and high-temperature cooling system. The present work evaluates the performance in relation to thermal comfort and energy consumption of a GSHP with different GHE concepts. The different configurations are analyzed being part of the energy supply system of a low-energy residential house...

  17. ADAPTIVE CONTENT BASED TEXTUAL INFORMATION SOURCE PRIORITIZATION

    Directory of Open Access Journals (Sweden)

    Nikhil Mitra

    2014-10-01

    Full Text Available The world-wide-web offers a posse of textual information sources which are ready to be utilized for several applications. In fact, given the rapidly evolving nature of online data, there is a real risk of information overload unless we continue to develop and refine techniques to meaningfully segregate these information sources. Specifically, there is a dearth of content-oriented and intelligent techniques which can learn from past search experiences and also adapt to a user’s specific requirements during her current search. In this paper, we tackle the core issue of prioritizing textual information sources on the basis of the relevance of their content to the central theme that a user is currently exploring. We propose a new Source Prioritization Algorithm that adopts an iterative learning approach to assess the proclivity of given information sources towards a set of user-defined seed words in order to prioritise them. The final priorities obtained serve as initial priorities for the next search request. This serves a dual purpose. Firstly, the system learns incrementally from several users’ cumulative search experiences and re-adjusts the source priorities to reflect the acquired knowledge. Secondly, the refreshed source priorities are utilized to direct a user’s current search towards more relevant sources while adapting also to the new set of keywords acquired from that user. Experimental results show that the proposed algorithm progressively improves the system’s ability to discern between different sources, even in the presence of several random sources. Further, it is able to scale well to identify the augmented information source when a new enriched information source is generated by clubbing existing ones.

  18. Quantum heat engines based on electronic Mach-Zehnder interferometers

    Science.gov (United States)

    Hofer, Patrick P.; Sothmann, Björn

    2015-05-01

    We theoretically investigate the thermoelectric properties of heat engines based on Mach-Zehnder interferometers. The energy dependence of the transmission amplitudes in such setups arises from a difference in the interferometer arm lengths. Any thermoelectric response is thus of purely quantum-mechanical origin. In addition to an experimentally established three-terminal setup, we also consider a two-terminal geometry as well as a four-terminal setup consisting of two interferometers. We find that Mach-Zehnder interferometers can be used as powerful and efficient heat engines which perform well under realistic conditions.

  19. SPECIFIC HEAT CAPACITY AND THERMAL CONDUCTIVITY OF HEAT STORAGE MATERIALS BASED ON PARAFFIN, BROWN-COAL WAX AND POLYETHYLENE WAX

    Directory of Open Access Journals (Sweden)

    Snezhkin Yu.

    2014-08-01

    Full Text Available The present paper overviews heat storage materials (HSM with phase change based on organic compounds. They consist of paraffin, brown-coal wax and polyethylene wax. These materials are produced on an industrial scale for the foundry work. It is shown that heat capacity of HSM in the solid and liquid states can be used for heat storage in addition to the heat of phase change. The results of investigations of phase change during heating and cooling HSM are presented. The studies are carried out by differential scanning calorimetry (DSC. The measurement techniques of the specific heat capacity and the coefficient of thermal conductivity are shown. Temperature dependences of the specific heat capacity of HSM in the solid and liquid states are researched by DSC. Values of the coefficient of thermal conductivity are determined by contact stationary technique of the flat plate over the entire temperature range of the operation of heat storage system.

  20. Stability of Continental Lithosphere based on Analogue Experiments with Microwave Induced Internal Heating

    Science.gov (United States)

    Fourel, Loic; Limare, Angela; Surducan, Emanoil; Surducan, Vasile; Neamtu, Camelia; Vilella, Kenny; Farnetani, Cinzia; Kaminski, Edouard; Jaupart, Claude

    2015-04-01

    Continental lithosphere is usually depicted as the upper conductive layer of the Earth. Its formation is achieved through melt depletion that generates a residue that is less dense and more viscous than the underlying convecting mantle. As it is cooled from above, continental lithosphere can develop its own convective currents and may become unstable depending on its thickness and density contrast with the mantle. But chemical differentiation due to mantle magmatism also enriches continental lithosphere in heat producing elements. According to present estimates, the Earth's mantle may have lost as much as half of its radioactive elements in favour of continental crust and this stratified redistribution of heat sources has two main effects. First, mantle convection vigor decreases and becomes increasingly sensitive to heat supply from the core. Second, localized heat production at the top surface increases the continental insulating effects and competes against lithospheric instabilities. In the present study, we focus on the later and we determine which amount of internal heating is required to keep the lithosphere stable for a given rate of cooling from the top. The physics underlying instability triggering corresponds to the problem of a two differentially heated layered system cooled from above, where the top layer is less dense and more viscous than the bottom one, representative of the lithosphere-mantle system. Few studies have been devoted to the intrinsic characteristics of this layered type of convection. Here, we present a state of the art laboratory setup to generate internal heating in controlled conditions based on microwave (MW) absorption. The volumetric heat source can be localized in space and its intensity can be varied in time. Our tank prototype has horizontal dimensions of 30 cm x 30 cm and 5 cm height. A uniform and constant temperature is maintained at the upper boundary by an aluminium heat exchanger and adiabatic conditions are imposed at

  1. Experimental study on heat supply of soil-seawater-source heat pump%土壤海水源热泵供暖实验研究

    Institute of Scientific and Technical Information of China (English)

    吴君华; 李海山; 牛林

    2014-01-01

    Sets up a field test platform of soil-seawater-source heat pump and performs heating experiment.The experimental results show that the higher the sand soil temperature is,the more the inlet water temperature of heat pump is,which results in larger heat exchanger capacity per unit length and higher COP of the heat pump system.Under the experimental conditions,the average value of heat exchanger capacity per unit length is 38.2 W/m,and the average value of COP is 1.8.The heat exchanger of soil-seawater-source heat pump system has little effect on the soil thermal environment due to stronger temperature restoration ability of shallow layer seabed soil.%搭建了土壤海水源现场实验台,进行了供暖实验。结果表明,沙层土壤温度越高,则机组进水温度也越高,单位管长换热量也就越大,热泵系统 COP 也就越大;实验工况下,单位管长换热量平均值为38.2 W/m,热泵系统COP 平均值为1.8;浅层海底沙层土壤温度恢复能力较强,盘管换热器对周围土壤热环境影响较小。

  2. Performance Evaluation of Air-Based Heat Rejection Systems

    Directory of Open Access Journals (Sweden)

    Hannes Fugmann

    2015-01-01

    Full Text Available On the basis of the Number of Transfer Units (NTU method a functional relation between electric power for fans/pumps and effectiveness in dry coolers and wet cooling towers is developed. Based on this relation, a graphical presentation method of monitoring and simulation data of heat rejection units is introduced. The functional relation allows evaluating the thermodynamic performance of differently sized heat rejection units and comparing performance among them. The method is used to evaluate monitoring data of dry coolers of different solar cooling field projects. The novelty of this approach is that performance rating is not limited by a design point or standardized operating conditions of the heat exchanger, but is realizable under flexible conditions.

  3. Embedded water-based surface heating part 2: experimental validation

    DEFF Research Database (Denmark)

    Karlsson, Henrik

    2010-01-01

    : hybrid 3D numerical model. Journal of Building Physics 33: 357-391). The thermal response of the system is tested in both long (16 h) and short (30 min) cycle experiments where the water flow alters between on and off. Temperature distribution, within the floor construction, and the heat exchange process...... are studied throughout the test cycles. The model underestimates the steady-state heat exchange from the pipe loop by 16% when boundary conditions and thermal properties according to the reference case are applied. Temperatures at the floor surface are assessed with good precision while temperatures......The transient operation of an embedded water-based floor heating system has been studied by means of a numerical simulation tool. Prior to this study, Caccavelli and Richard (Caccavelli D, Richard P (1994) Etude portant sur le dimensionnement d'un plancher chauffant a eau chaude en CIC. Rapport n...

  4. Continued Water-Based Phase Change Material Heat Exchanger Development

    Science.gov (United States)

    Hansen, Scott W.; Sheth, Rubik B.; Poynot, Joe; Giglio, Tony; Ungar, Gene K.

    2015-01-01

    In a cyclical heat load environment such as low Lunar orbit, a spacecraft's radiators are not sized to meet the full heat rejection demands. Traditionally, a supplemental heat rejection device (SHReD) such as an evaporator or sublimator is used to act as a "topper" to meet the additional heat rejection demands. Utilizing a Phase Change Material (PCM) heat exchanger (HX) as a SHReD provides an attractive alternative to evaporators and sublimators as PCM HX's do not use a consumable, thereby leading to reduced launch mass and volume requirements. In continued pursuit of water PCM HX development two full-scale, Orion sized water-based PCM HX's were constructed by Mezzo Technologies. These HX's were designed by applying prior research on freeze front propagation to a full-scale design. Design options considered included bladder restraint and clamping mechanisms, bladder manufacturing, tube patterns, fill/drain methods, manifold dimensions, weight optimization, and midplate designs. Two units, Units A and B, were constructed and differed only in their midplate design. Both units failed multiple times during testing. This report highlights learning outcomes from these tests and are applied to a final sub-scale PCM HX which is slated to be tested on the ISS in early 2017.

  5. Temperature and energy deficit in the ground during operation and recovery phases of closed-loop ground source heat pump system: Effect of the groundwater flow

    Science.gov (United States)

    Erol, Selcuk; Francois, Bertrand

    2016-04-01

    The advection/dispersion mechanism of the groundwater flow in the ground has a significant effect on a borehole heat exchanger (BHE) to enhance its thermal performance. However, the amount of energy extracted from the ground never disappears and only shifts with the magnitude of the effective thermal velocity in the infinite domain. In this work, we focus on the temperature and the energy balance of the ground in an advection/dispersion dominated heat transfer system during the operation period of a BHE and the subsequent recovery phase when the system is idle. The problem is treated with single BHE and multi-BHEs systems, for different representative geology and different groundwater flow velocity. In order to assess the thermal energy deficit due to heat extraction from the ground, we used the finite line source analytical model, developed recently (Erol et al., 2015) that provides the temperature distributions around the boreholes for discontinuous heat extraction. The model is developed based on the Green's function, which is the solution of heat conduction/advection/dispersion equation in porous media, for discontinuous heat extraction by analytically convoluting rectangular function or pulses in time domain. The results demonstrate the significant positive impact of the groundwater flow for the recovery in terms of temperature deficit at the location of the borehole. However, the total thermal energy deficit is not affected by the groundwater movement. The energy balance of the ground is the same no matter the prevailing heat transfer system, which can be only conduction or advection/dispersion. In addition, the energy balance of the ground is not based on either the duration of the production period operation or of the recovery phase, but depends on the total amount of heat that is extracted and on the bulk volumetric heat capacity of the ground.

  6. Influence of outdoor temperature fluctuation on air-source heat pump radiant floor heating%室外温度波动对空气源热泵辐射地板供暖的影响

    Institute of Scientific and Technical Information of China (English)

    李元哲

    2014-01-01

    根据3组实测数据分析了空气源热泵用于寒冷地区(ⅡB)时的热特性。针对典型的辐射供暖地板,用数值计算方法对某示范工程的空气源热泵辐射地板供暖进行了传热过程计算,发现室温计算值和实测值吻合较好,说明由于地板有较大的热容量,采用这种系统室温稳定性可以得到保障。%According to three group testing data,analyses thermal characteristics of the air-source heat pump applied to cold zone (ⅡB).Based on the typical radiant heating floor,calculates the heat transfer performance of the air-source heat pump radiant floor heating for a demonstration project using numerical calculation method,and the calculation values are coincident with the testing data,which indicates that the stability of indoor temperature can be guaranteed because of the large thermal capacity of the floor.

  7. Moving heat source response in micropolar half-space with two-temperature theory

    Science.gov (United States)

    Shaw, Soumen; Mukhopadhyay, Basudeb

    2013-03-01

    The present paper deals with the moving heat source response in a homogeneous, isotropic, micropolar semi-infinite medium in the presence of a finite rotation about its axis. In this context, two-temperature generalized thermoelasticity theory has been considered. In order to obtain the physical aspects of displacement, microrotation, stress distribution and temperature changes, a complex quartic equation has been solved by employing Descartes' algorithm with the help of an irreducible Cardan's method. To illustrate the analytical developments, the numerical solutions have been carried out for aluminum-epoxy composite, and the variations in displacement, microrotation, stress distribution and temperature changes have been shown graphically. This work may find applications in geophysics.

  8. Titanium tritide radioisotope heat source development : palladium-coated titanium hydriding kinetics and tritium loading tests.

    Energy Technology Data Exchange (ETDEWEB)

    Van Blarigan, Peter; Shugard, Andrew D.; Walters, R. Tom (Savannah River National Labs, Aiken, SC)

    2012-01-01

    We have found that a 180 nm palladium coating enables titanium to be loaded with hydrogen isotopes without the typical 400-500 C vacuum activation step. The hydriding kinetics of Pd coated Ti can be described by the Mintz-Bloch adherent film model, where the rate of hydrogen absorption is controlled by diffusion through an adherent metal-hydride layer. Hydriding rate constants of Pd coated and vacuum activated Ti were found to be very similar. In addition, deuterium/tritium loading experiments were done on stacks of Pd coated Ti foil in a representative-size radioisotope heat source vessel. The experiments demonstrated that such a vessel could be loaded completely, at temperatures below 300 C, in less than 10 hours, using existing department-of-energy tritium handling infrastructure.

  9. Comparative study of beam losses and heat loads reduction methods in MITICA beam source

    Energy Technology Data Exchange (ETDEWEB)

    Sartori, E., E-mail: emanuele.sartori@igi.cnr.it; Agostinetti, P.; Dal Bello, S.; Marcuzzi, D.; Serianni, G.; Veltri, P. [Consorzio RFX, Euratom-ENEA association, C.so Stati Uniti 4, 35127 Padova (Italy); Sonato, P. [Consorzio RFX, Euratom-ENEA association, C.so Stati Uniti 4, 35127 Padova (Italy); Dipartimento di Ingegneria Elettrica, Padova University, Via Gradenigo 6/a, 35131 Padova (Italy)

    2014-02-15

    In negative ion electrostatic accelerators a considerable fraction of extracted ions is lost by collision processes causing efficiency loss and heat deposition over the components. Stripping is proportional to the local density of gas, which is steadily injected in the plasma source; its pumping from the extraction and acceleration stages is a key functionality for the prototype of the ITER Neutral Beam Injector, and it can be simulated with the 3D code AVOCADO. Different geometric solutions were tested aiming at the reduction of the gas density. The parameter space considered is limited by constraints given by optics, aiming, voltage holding, beam uniformity, and mechanical feasibility. The guidelines of the optimization process are presented together with the proposed solutions and the results of numerical simulations.

  10. Comparative study of beam losses and heat loads reduction methods in MITICA beam source

    Science.gov (United States)

    Sartori, E.; Agostinetti, P.; Dal Bello, S.; Marcuzzi, D.; Serianni, G.; Sonato, P.; Veltri, P.

    2014-02-01

    In negative ion electrostatic accelerators a considerable fraction of extracted ions is lost by collision processes causing efficiency loss and heat deposition over the components. Stripping is proportional to the local density of gas, which is steadily injected in the plasma source; its pumping from the extraction and acceleration stages is a key functionality for the prototype of the ITER Neutral Beam Injector, and it can be simulated with the 3D code AVOCADO. Different geometric solutions were tested aiming at the reduction of the gas density. The parameter space considered is limited by constraints given by optics, aiming, voltage holding, beam uniformity, and mechanical feasibility. The guidelines of the optimization process are presented together with the proposed solutions and the results of numerical simulations.

  11. Attenuation of Scintillation of Discrete Cosmic Sources during Nonresonant HF Heating of the Upper Ionosphere

    Science.gov (United States)

    Bezrodny, V. G.; Watkins, B.; Charkina, O. V.; Yampolski, Y. M.

    2014-03-01

    The aim of the work is to experimentally investigate the response of scintillation spectra and indices of discrete cosmic sources (DCS) to modification of the ionospheric F-region by powerful electromagnetic fields with frequencies exceeding the Langmuir and upper hybrid ones. The results of a special experiment on the scintillations of radiation from DCS Cygnus A observed with using the 64-beam imaging riometer located near the Gakona village (Alaska, USA) are here presented. The ionosphere was artificially disturbed by powerful HAARP heater. Under the studied conditions of nonresonant heating of the ionospheric plasma, an earlier unknown effect of reducing the level of DCS scintillation was discovered. The theoretical interpretation has been given for the discovered effect, which using allowed the proposed technique of solving the inverse problem (recovery deviations of average electron density and temperature in the modified region from their unperturbed values).

  12. Aerodynamic levitation and laser heating: Applications at synchrotron and neutron sources

    Energy Technology Data Exchange (ETDEWEB)

    Hennet, L.; Pozdnyakova, I.; Drewitt, J.W.E.; Leydier, M.; Brassamin, S.; Zanghi, D.; Magazu, S.; Price, D.L. [CEMHTI and University of Orleans, 45071 Orleans Cedex 02 (France); Cristiglio, V.; Kozaily, J.; Fischer, H.E.; Cuello, G.J.; Koza, M. [ILL, BP. 156, 38042 Grenoble Cedex 09 (France); Bytchkov, A. [ESRF, BP. 220, 38043 Grenoble Cedex 09 (France); Thiaudiere, D. [Synchrotron SOLEIL, BP. 48, 91192 Gif-sur-Yvette Cedex (France); Gruner, S. [Institute of Physics, Chemnitz UT, 09107 Chemnitz (Germany); Greaves, G.N. [IMAPS, University of Wales, Aberystwyth, SY23 3BZ (United Kingdom)

    2011-05-15

    Aerodynamic levitation is an effective way to suspend samples which can be heated with CO{sub 2} lasers. The advantages of this container-less technique are the simplicity and compactness of the device, making it possible to integrate it easily in different kinds of experiments. In addition, all types of materials can be used, including metals and oxides. The integration of aerodynamic levitation at synchrotron and neutron sources provides powerful tools to study the structure and dynamics of molten materials. We present here an overview of the existing techniques (electromagnetic levitation, electrostatic levitation, single-axis acoustic levitation, and aerodynamic levitation) and of the developments made at the CEMHTI in Orleans, as well as a few examples of experimental results already obtained. (authors)

  13. Literature Review: Weldability of Iridium DOP-26 Alloy for General Purpose Heat Source

    Energy Technology Data Exchange (ETDEWEB)

    Burgardt, Paul [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Pierce, Stanley W. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-10-19

    The basic purpose of this paper is to provide a literature review relative to fabrication of the General Purpose Heat Source (GPHS) that is used to provide electrical power for deep space missions of NASA. The particular fabrication operation to be addressed here is arc welding of the GPHS encapsulation. A considerable effort was made to optimize the fabrication of the fuel pellets and of other elements of the encapsulation; that work will not be directly addressed in this paper. This report consists of three basic sections: 1) a brief description of the GPHS will be provided as background information for the reader; 2) mechanical properties and the optimization thereof as relevant to welding will be discussed; 3) a review of the arc welding process development and optimization will be presented. Since the welding equipment must be upgraded for future production, some discussion of the historical establishment of relevant welding variables and possible changes thereto will also be discussed.

  14. Regulatory framework and examples of ground-source heating/cooling technology in the Winnipeg area

    Energy Technology Data Exchange (ETDEWEB)

    Matthews, R. [Manitoba Conservation, Winnipeg, MB (Canada)

    2003-07-01

    Winnipeg, Manitoba lies over a highly transmissive Carbonate Aquifer of Ordovician age, which provides a suitable environment for groundwater supply and return wells. Many licensed ground-source heating cooling (GSHC) systems have been installed in and around the Winnipeg urban area over the last several decades. A water rights licence, issued by the Provincial Department of Conservation, is required for all groundwater supply and return wells. This licence comes with certain rights and responsibilities. This paper describes the regulatory framework which governs the licensing process. The author emphasized that the future use and success of the technology depends, in large part, on the development of a critical mass of experienced contractors, hydrogeologists and consulting engineers. 2 refs.

  15. Advanced RF Sources Based on Novel Nonlinear Transmission Lines

    Science.gov (United States)

    2015-01-26

    crowding and therefore highest temperature due to joule heating, occurs at the constriction corner near the source side , which is point B in Fig. 4(c...Boltzmann transport equation in orifice and disk geometry,” Proc. Phys. Soc. 89, 927 (1966). [23] Peng Zhang, Y. Y. Lau, and R. M. Gilgenbach, “Analysis of

  16. MULTI-HEAT SOURCE SOLAR HEAT PUMP HEAT SUPPLY SYSTEM AND PERFORMANCE SIMULATION%复合热源太阳能热泵供热系统及其性能模拟

    Institute of Scientific and Technical Information of China (English)

    杨磊; 张小松

    2011-01-01

    提出了一种复合热源太阳能热泵供热系统,通过阀门切换,可根据不同的天气状况改变运行模式,以空气和太阳辐射作为热源制取供暖用水.针对所设计的lOkw供热系统,建立了系统的数学模型,对热泵串联集热器(SC+HP)及集热器串联热泵(HP+SC)两种运行模式下的循环性能进行了计算机模拟分析,并计算了系统的全年运行状况.从模拟结果可以看出,在模拟进水温度区间内,HP+SC模式下热泵COP较高,最高比SC+HP模式高2.58%;而SC+HP模式集热器热性能较好,总热效率更高,最高比HP+SC模式高2.62%.%A compound solar heat pump heat supply system was presented. The system can make heating water from air source and solar radiation by valve switching, based on different weather conditions. A numerical model for a l0kW heating utilizing was established. The circulation performances of solar collector with heat pump( SC + HP) and heat pump with solar collector( Hp + SC) operation modes were simulated. The all year round operation status was also caculated.The results have shown that the COP of HP + SC mode is at most 2.58 % higher than SC + HP mode in simulation water temperature range. But the latter has a better collector thermal performance and overall thermal efficiency is at most 2.62 % higher than the former.

  17. On the Response of an OST to a Point-like Heat Source

    CERN Document Server

    Quadt, A; Uhrmacher, M; Weingarten, J; Willenberg, B; Vennekate, H

    2011-01-01

    A new technique of superconducting cavity diagnostics has been introduced by D. Hartrill at Cornell University, Ithaca, USA. Oscillating Superleak Transducers (OST) detect the heat transferred from a cavity's quench point via "Second Sound" through the superfluid He bath, needed to cool the superconducting cavity. The observed response of an OST is a complex, but reproducible pattern of oscillations. A small helium evaporation cryostat was built which allows the investigation of the response of an OST in greater detail. The distance between a point-like electrical heater and the OST can be varied. The OST can be mounted either parallel or perpendicular to the plate, housing the heat source. If the artificial quench-point releases an amount of energy compatible to a real quench spot on a cavity's surface, the OST signal starts with a negative pulse, which is usually strong enough to allow automatic detection. Furthermore, the reflection of the Second Sound on the wall is observed. A reflection coefficient R = ...

  18. Geothermal(Ground-Source)Heat Pumps: Market Status, Barriers to Adoption, and Actions to Overcome Barriers

    Energy Technology Data Exchange (ETDEWEB)

    Hughes, Patrick [ORNL

    2008-12-01

    More effective stewardship of our resources contributes to the security, environmental sustainability, and economic well-being of the nation. Buildings present one of the best opportunities to economically reduce energy consumption and limit greenhouse gas emissions. Geothermal heat pumps (GHPs), sometimes called ground-source heat pumps, have been proven capable of producing large reductions in energy use and peak demand in buildings. However, GHPs have received little attention at the policy level as an important component of a national strategy. Have policymakers mistakenly overlooked GHPs, or are GHPs simply unable to make a major contribution to the national goals for various reasons? This brief study was undertaken at DOE's request to address this conundrum. The scope of the study includes determining the status of global GHP markets and the status of the GHP industry and technology in the United States, assembling previous estimates of GHP energy savings potential, identifying key barriers to application of GHPs, and identifying actions that could accelerate market adoption of GHPs. The findings are documented in this report along with conclusions and recommendations.

  19. Promoting renewable energy sources for heating and cooling in EU-27 countries

    Energy Technology Data Exchange (ETDEWEB)

    Cansino, Jose M., E-mail: jmcansino@us.es [Department of Economic Analysis and Political Economy, Seville University, Avda. Ramon y Cajal, no. 1, 41018 Seville (Spain); Pablo-Romero, Maria del P. [Department of Economic Analysis and Political Economy, Seville University, Avda. Ramon y Cajal, no. 1, 41018 Seville (Spain); Roman, Rocio, E-mail: rroman@us.es [Department of Economic Analysis and Political Economy, Seville University, Avda. Ramon y Cajal, no. 1, 41018 Seville (Spain); Yniguez, Rocio [Department of Economic Analysis and Political Economy, Seville University, Avda. Ramon y Cajal, no. 1, 41018 Seville (Spain)

    2011-06-15

    In addition to public policies aimed at improving the energy efficiency of buildings, EU authorities have also promoted the use of Renewable Energy Sources for heating and cooling uses (RES H and C). This paper analyses the main policy measures implemented in EU-27 countries up to 2009: i.e. subsidies, tax incentives, financial support and feed-in tariffs. Twenty-three Member States (MSs) have developed some of these policy measures. The most widespread measure is the subsidy (22 MSs have implemented these) because from a political point of view, subsidies provide a straightforward approach to promote the use of RES H and C. Secondly, tax incentives have been used for reducing investment costs and making renewable energy profitable. Thirdly, financial incentives and feed-in tariffs have been used sparingly. While financial incentives might be used more extensively for promoting RES H and C if they are accompanied by other policy measures, feed-in tariffs are not likely to be implemented significantly in the future because this measure is not designed for household heat producers. - Highlights: > Main EU policies to reduce energy consumption are focused on buildings' efficiency. > Alternative incentives to promote the use of RES H and C in EU-27 are now studied. > Subsidies are the most widespread measure. > Tax incentives are used for reducing investment costs and making RES profitable. > Financial incentives and feed-in tariffs have been used sparingly.

  20. High current multicharged metal ion source using high power gyrotron heating of vacuum