Sample records for heat recovering units

  1. Waste heat recovering device for reactors

    Sonoda, Masanobu; Shiraishi, Tadashi; Mizuno, Hiroyuki; Sekine, Yasuhiro.

    1982-01-01

    Purpose: To enable utilization of auxiliary-equipment-cooling water from a non-regenerative heat exchanger as a heat source, as well as prevent radioactive contamination. Constitution: A water warming device for recovering the heat of auxiliary equipment cooling water from a non-regenerative heat exchanger is disposed at the succeeding stage of the heat exchanger. Heat exchange is performed in the water warming device between the auxiliary equipment cooling water and a heat source water set to a higher pressure and recycled through the water warming device. The heat recovered from the auxiliary equipment cooling water is utilized in the heat source water for operating relevant equipments. (Aizawa, K.)

  2. Recovering heat from waste air from stables

    1983-01-01

    A milk cow gives off 35.7 kW h/d via its body, excreta and urine. 68.4% of this is body heat. Part of this waste heat escapes with the waste air from the cowsheds. The heat can be recovered from the waste air by an air/air heat exchanger. The air is collected and taken to a heat exchanger. In the heat exchanger, fresh air is heated by the waste air, and is distributed over the cowshed by a system of ducts. The heated waste air escapes through a central chimney at the end of the heat exchanger. It is sensible to fit the heat exchanger above the cowshed roof, if there is sufficient space available and the chimney should run upwards from the cowshed. A double heat exchanger makes it possible to allocate each half of the cowshed to half of the heat exchanger.

  3. Selection of cooling fluid for an organic Rankine cycle unit recovering heat on a container ship sailing in the Arctic region

    Suárez de la Fuente, Santiago; Larsen, Ulrik; Pierobon, Leonardo

    2017-01-01

    As Arctic sea ice coverage declines it is expected that marine traffic could increase in this northern region due to shorter routes. Navigating in the Arctic offers opportunities and challenges for waste heat recovery systems (WHRS). Lower temperatures require larger heating power on board, hence...... air as coolant. This paper explores the use of two different coolants, air and seawater, for an organic Rankine cycle (ORC) unit using the available waste heat in the scavenge air system of a container ship navigating in Arctic Circle. Using a two-step single objective optimisation process, detailed...

  4. Control system pre-feedbacked for the super heated steam temperature in heat recovering units; Sistema de control pre-retroalimentado para la temperatura de vapor sobrecalentado en recuperadores de calor

    Lopez Alvarez, Hilario; Madrigal Espinosa, Guadalupe [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1996-12-31

    The study that is presented corresponds to the analysis, design and development of a pre-feedbacked control system for the superheated steam temperature regulation in the heat recovery units of a combined cycle thermoelectric power plant. The designs of the feedback controller and the pre-feedback control system were implemented based in a linear model of the tempering zone. This linear model was obtained through the application of parametric identification techniques to the non-linear mathematical model of a combined cycle power plant. [Espanol] El estudio que se presenta corresponde al analisis, diseno y desarrollo de un sistema de control pre-retroalimentado para regular la temperatura de vapor sobrecalentado en los recuperadores de calor de una central termoelectrica de ciclo combinado. Los disenos del controlador retroalimentado y del sistema de control prealimentado se realizaron con base en un modelo lineal de la zona de atemperacion. Este modelo lineal se obtuvo aplicando tecnicas de identificacion parametrica al modelo matematico no-lineal de una central de ciclo combinado.

  5. Control system pre-feedbacked for the super heated steam temperature in heat recovering units; Sistema de control pre-retroalimentado para la temperatura de vapor sobrecalentado en recuperadores de calor

    Lopez Alvarez, Hilario; Madrigal Espinosa, Guadalupe [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1997-12-31

    The study that is presented corresponds to the analysis, design and development of a pre-feedbacked control system for the superheated steam temperature regulation in the heat recovery units of a combined cycle thermoelectric power plant. The designs of the feedback controller and the pre-feedback control system were implemented based in a linear model of the tempering zone. This linear model was obtained through the application of parametric identification techniques to the non-linear mathematical model of a combined cycle power plant. [Espanol] El estudio que se presenta corresponde al analisis, diseno y desarrollo de un sistema de control pre-retroalimentado para regular la temperatura de vapor sobrecalentado en los recuperadores de calor de una central termoelectrica de ciclo combinado. Los disenos del controlador retroalimentado y del sistema de control prealimentado se realizaron con base en un modelo lineal de la zona de atemperacion. Este modelo lineal se obtuvo aplicando tecnicas de identificacion parametrica al modelo matematico no-lineal de una central de ciclo combinado.

  6. Technologies and Materials for Recovering Waste Heat in Harsh Environments

    Nimbalkar, Sachin U. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Thekdi, Arvind [E3M, Inc. North Potomac, MD (United States); Rogers, Benjamin M. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Kafka, Orion L. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Wenning, Thomas J. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2014-12-15

    A large amount (7,204 TBtu/year) of energy is used for process heating by the manufacturing sector in the United States (US). This energy is in the form of fuels mostly natural gas with some coal or other fuels and steam generated using fuels such as natural gas, coal, by-product fuels, and some others. Combustion of these fuels results in the release of heat, which is used for process heating, and in the generation of combustion products that are discharged from the heating system. All major US industries use heating equipment such as furnaces, ovens, heaters, kilns, and dryers. The hot exhaust gases from this equipment, after providing the necessary process heat, are discharged into the atmosphere through stacks. This report deals with identification of industries and industrial heating processes in which the exhaust gases are at high temperature (>1200 F), contain all of the types of reactive constituents described, and can be considered as harsh or contaminated. It also identifies specific issues related to WHR for each of these processes or waste heat streams.

  7. A system recovering heat from exhaust gases. Abgasenergie-Rueckgewinnungseinrichtung

    John, E; Hultsch, H; Brendorp, W

    1990-08-16

    The proposed exhaust gas heat recovery system is provided with a hydraulic clutch (8) which is located between a gas tubine (2) to be driven by the exhaust gases of an internal combustion engine (20) and a drive unit (18) of the internal combustion engine (20). A mechanical blocking device (6) prevents the turbine from running at explosion speed when the hydraulic clutch (8) is emptied or when the oil pressure of the hydraulic clutch drops below a certain minimum.

  8. Organic Rankine Cycle recovering stage heat from MSF desalination distillate water

    Al-Weshahi, Mohammed A.; Anderson, Alexander; Tian, Guohong

    2014-01-01

    Highlights: • The ORC model is validated against measured performance of an existing ORC unit. • This ORC model highlights the importance of refrigerant choice (R245fa performs better than R134a for this specific application). • For heat recovery from desalination plant, ORC evaporator and cooling water temperatures significantly influence the performance. - Abstract: This investigation addresses the potential for heat recovery from Multi Stage Flash (MSF) desalination plant hot distillate water to power an Organic Rankine Cycle (ORC), comparing R134a and R245fa refrigerants as the working fluid. Using design characteristics of an existing ORC unit, the model was first validated against its measured output. The distillate hot water from MSF stages is utilised to provide heat to the ORC and performance is investigated for both working fluids and for the number of MSF stages for heat recovery. For the specific MSF plant investigated, the net produced ORC power is found the highest with extraction up to MSF powering stage 8, generating 359 kW when R245fa is used and 307 kW when R134a is used. Both refrigerants exhibit an increase of power output and decrease of energy efficiency as heat is recovered from more MSF stages. The influence of variation of the evaporator and cooling temperature on ORC performance is demonstrated to be significant for both refrigerants, with R245fa performing better in this specific application

  9. An experimental study of the enhanced heating capacity of an electric heat pump (EHP) using the heat recovered from a gas engine generator

    Kim, Cheol Min; Chang, Se Dong [HAC R and D Laboratory, LG Electronics, 327-23 Gasan-Dong, Geumcheon-gu, Seoul 153-802 (Korea); Lee, Jaekeun; Hwang, Yujin [School of Mechanical Engineering, Pusan National University, San 30, Changjeon-Dong, Keumjeong-Ku, Busan 609-735 (Korea)

    2009-11-15

    This paper is concerned with the effect of recovered heat on the heating capacity of an Electric Heat Pump (EHP), which is supplied with electric power and recovered heat from a gas engine generator system. Two methods of supplying recovery heat are examined: (i) to the refrigerant with the discharge line heat exchanger (HEX), and (ii) to the refrigerant of the evaporator with the sub-evaporator. Heating capacity, input power and coefficient of performance (COP) were investigated and compared for each heat recovery method. Conclusively, we found that the second method was most reasonable to recover wasted heat and increased system COP by 215%. (author)

  10. Projecting recovered paper supply in the United States.

    James L. Howard; Ken Skog; Peter J. Ince

    2002-01-01

    The use of recovered paper has an influence on the amount of timber harvested as well as the feasibility of expanded recycling programs. During the 1990’s markets and prices for recovered materials have fluctuated widely. There are a number of factors driving these market changes including economic conditions domestically and internationally. The objective of this...

  11. New device architecture of a thermoelectric energy conversion for recovering low-quality heat

    Kim, Hoon; Park, Sung-Geun; Jung, Buyoung; Hwang, Junphil; Kim, Woochul

    2014-03-01

    Low-quality heat is generally discarded for economic reasons; a low-cost energy conversion device considering price per watt, /W, is required to recover this waste heat. Thin-film based thermoelectric devices could be a superior alternative for this purpose, based on their low material consumption; however, power generated in conventional thermoelectric device architecture is negligible due to the small temperature drop across the thin film. To overcome this challenge, we propose new device architecture, and demonstrate approximately 60 Kelvin temperature differences using a thick polymer nanocomposite. The temperature differences were achieved by separating the thermal path from the electrical path; whereas in conventional device architecture, both electrical charges and thermal energy share same path. We also applied this device to harvest body heat and confirmed its usability as an energy conversion device for recovering low-quality heat.

  12. Ukrainian brown-coal tars recovered at low-temperature carbonization with solid heating medium

    Kuznetsov, V I; Govorova, R P; Fadeicheva, A G; Kigel, T B; Chernykh, M K

    1955-01-01

    Three samples of tar were recovered in the laboratory from brown coals carbonized at 375/sup 0/ to 456/sup 0/ +- 25/sup 0/ in a retort with inner heating by solid circulating medium, namely, semicoke (ratio: 4 or 3:1) first heated to 700/sup 0/. One comparative (parallel) experiment was carried out in a retort with inner heating by inert gases entering the retort at 580/sup 0/ to 600/sup 0/ and leaving it at 115/sup 0/ to 120/sup 0/. The tars that were recovered from the retort with the solid heating medium contained a high percentage of coal dust and moisture, which were separated from the tars in supercentrifuges (15,000 rpm). Four samples of cleaned tars were fractionated in a Cu flask with a 2-ball fractional column. The tars from the retort with the solid-heating medium are characterized by increased yield of the petroleum-ether fraction (16.3 or 19.3%) and decreased yield of the paraffin fraction (15.1 to 21.2%) in comparison with those of tar from the retort with gas heating (5.9% of the petroleum ether fraction and 36.5% of paraffin fraction). The yield of paraffin from the paraffin fraction also decreased from 90.6% to 62.6-74.3%. This result shows that in the first case the carbonized products were cracked to a higher degree than those from the retort with gas heating. In raw phenols recovered from fractions of investigated tars, the yield of the phenol-cresol fraction (182/sup 0/ to 204/sup 0/) decreased from 25.9% to 13.0-18.9%.

  13. Prototype implementation and experimental analysis of water heating using recovered waste heat of chimneys

    Mahmoud Khaled

    2015-03-01

    Full Text Available This work discusses a waste heat recovery system (WHRS applied to chimneys for heating water in residential buildings. A prototype illustrating the suggested system is implemented and tested. Different waste heat scenarios by varying the quantity of burned firewood (heat input are experimented. The temperature at different parts of the WHRS and the gas flow rates of the exhaust pipes are measured. Measurements showed that the temperature of 95 L tank of water can be increased by 68 °C within one hour. Obtained results show that the convection and radiation exchanges at the bottom surface of the tank have a considerable impact on the total heat transfer rate of the water (as high as 70%.

  14. Recov'Heat: An estimation tool of urban waste heat recovery potential in sustainable cities

    Goumba, Alain; Chiche, Samuel; Guo, Xiaofeng; Colombert, Morgane; Bonneau, Patricia

    2017-02-01

    Waste heat recovery is considered as an efficient way to increase carbon-free green energy utilization and to reduce greenhouse gas emission. Especially in urban area, several sources such as sewage water, industrial process, waste incinerator plants, etc., are still rarely explored. Their integration into a district heating system providing heating and/or domestic hot water could be beneficial for both energy companies and local governments. EFFICACITY, a French research institute focused on urban energy transition, has developed an estimation tool for different waste heat sources potentially explored in a sustainable city. This article presents the development method of such a decision making tool which, by giving both energetic and economic analysis, helps local communities and energy service companies to make preliminary studies in heat recovery projects.

  15. Energetic and Exergy Efficiency of a Heat Storage Unit for Building Heating

    Hazami, Mejdi; Kooli, Sami; Lazaar, Meriem; Farhat, Abdelhamid; Belghith, Ali

    2009-01-01

    This paper deals with a numerical and experimental investigation of a daily solar storage system conceived and built in Laboratoire de Maitrise des Technologies de l Energie (LMTE, Borj Cedria). This system consists mainly of the storage unit connected to a solar collector unit. The storage unit consists of a wooden case with dimension of 5 m 3 (5 m x 1m x 1m) filed with fin sand. Inside the wooden case was buried a network of a polypropylene capillary heat exchanger with an aperture area equal to 5 m 2 . The heat collection unit consisted of 5 m 2 of south-facing solar collector mounted at a 37 degree tilt angle. In order to evaluate the system efficiency during the charging period (during the day) and discharging period (during the night) an energy and exergy analyses were applied. Outdoor experiments were also carried out under varied environmental conditions for several consecutive days. Results showed that during the charging period, the average daily rates of thermal energy and exergy stored in the heat storage unit were 400 and 2.6 W, respectively. It was found that the net energy and exergy efficiencies in the charging period were 32 pour cent and 22 pour cent, respectively. During the discharging period, the average daily rates of the thermal energy and exergy recovered from the heat storage unit were 2 kW and 2.5 kW, respectively. The recovered heat from the heat storage unit was used for the air-heating of a tested room (4 m x 3 m x 3 m). The results showed that 30 pour cent of the total heating requirement of the tested room was obtained from the heat storage system during the whole night in cold seasons

  16. A systematic method to customize an efficient organic Rankine cycle (ORC) to recover waste heat in refineries

    Yu, Haoshui; Feng, Xiao; Wang, Yufei; Biegler, Lorenz T.; Eason, John

    2016-01-01

    Highlights: • Multiple waste heat streams in refinery are recovered for an ORC using a hot water intermediate. • WHCC and GCC are used to identify opportunities to save utility and/or upgrade waste heat. • The methods consider the interaction between the HEN and ORC in an integrated manner. - Abstract: Organic Rankine cycles (ORCs) convert low temperature waste heat into power. When there are multiple waste heat sources in a refinery, operability and safety considerations may make it more practical to use hot water as the medium to recover waste heat. The hot water stream can then release the heat to the organic working fluid in an ORC system. In this paper, how to customize an efficient ORC for a heat exchanger network (HEN) to optimally recover multiple strands of waste heat is investigated. Because the heat exchanger network structure, the hot water loop, and ORC system interact with each other, the coordination and synthesis of these systems ought to be considered simultaneously to maximize the energy performance. A methodology is proposed using the waste heat composite curve (WHCC) and grand composite curve (GCC) to diagnose inefficiencies in an existing heat exchanger network. In addition, the WHCC can be used to solve the problem of the tradeoff between waste heat quality and quantity recovered with an intermediate stream. WHCCs are classified into two types, and procedures for designing the recovery network for each type are presented while considering the interaction with working fluid selection. The methods proposed in this paper can help engineers diagnose problems with the original heat exchanger network, and determine the flowrate of hot water, the structure of the waste heat recovery network, the best working fluid and the operating conditions of ORC system in an integrated manner. The ideas are applied to an illustrative case study in collaboration with Sinopec. The case study shows the effectiveness of this method and compares different

  17. A unified approach to assess performance of different techniques for recovering exhaust heat from gas turbines

    Carapellucci, Roberto

    2009-01-01

    Exhaust heat from gas turbines can be recovered externally or internally to the cycle itself. Of the technology options for external recovery, the combined gas-steam power plant is by far the most effective and commonly used worldwide. For internal recovery conventional solutions are based on thermodynamic regeneration and steam injection, while innovative solutions rely on humid air regeneration and steam reforming of fuel. In this paper a unified approach for analysing different exhaust heat recovery techniques is proposed. It has been possible to define a characteristic internal heat recovery plane, based on a few meaningful parameters and to identify an innovative scheme for repowering existing combined cycles. The characteristic plane indicates directly the performance obtainable with the different recovery techniques, showing that performances close to combined cycle plants (external recovery) can only be achieved with combined recovery techniques (humid air regeneration, steam reforming of fuel). The innovative repowering scheme, which requires the addition of a gas turbine and one-pressure level HRSG to an existing combined gas-steam power plant, significantly increases power output with fairly high marginal efficiency.

  18. Distillation of shale and other bituminous substances. [shale granules wetted, mixed with lime, heated; sulfur recovered

    Noad, J

    1912-09-23

    A process is described for the treatment of shale and other bituminous substances containing sulfur and recovering desulfurized distillates. The process consists of first grinding the shale and mixing the granules obtained with a convenient liquid. The shale granules coated or covered with liquid and mixed with slacked lime are fed into a retort with a series of steps or their equivalent, made to descend, step by step, in such manner that they are continually agitated and heated. The volatile constituents escape through the coating or sheath of lime and are carried away at the upper part of the retort to a convenient condensing apparatus, the sulfur being retained by the sheath of lime and is discharged at the bottom of the retort with the spent shale and other impurities.

  19. Indoor unit for electric heat pump

    Draper, R.; Lackey, R.S.; Fagan, T.J. Jr.; Veyo, S.E.; Humphrey, J.R.

    1984-05-22

    An indoor unit for an electric heat pump is provided in modular form including a refrigeration module, an air mover module, and a resistance heat package module, the refrigeration module including all of the indoor refrigerant circuit components including the compressor in a space adjacent the heat exchanger, the modules being adapted to be connected to air flow communication in several different ways as shown to accommodate placement of the unit in various orientations. 9 figs.

  20. Opportunity Analysis for Recovering Energy from Industrial Waste Heat and Emissions

    Viswanathan, Vish V.; Davies, Richard W.; Holbery, Jim D.

    2006-04-01

    United States industry consumed 32.5 Quads (34,300 PJ) of energy during 2003, which was 33.1% of total U.S. energy consumption (EIA 2003 Annual Energy Review). The U.S. industrial complex yields valuable goods and products. Through its manufacturing processes as well as its abundant energy consumption, it supports a multi-trillion dollar contribution to the gross domestic product and provides millions of jobs in the U.S. each year. Industry also yields waste products directly through its manufacturing processes and indirectly through its energy consumption. These waste products come in two forms, chemical and thermal. Both forms of waste have residual energy values that are not routinely recovered. Recovering and reusing these waste products may represent a significant opportunity to improve the energy efficiency of the U.S. industrial complex. This report was prepared for the U.S. Department of Energy Industrial Technologies Program (DOE-ITP). It analyzes the opportunity to recover chemical emissions and thermal emissions from U.S. industry. It also analyzes the barriers and pathways to more effectively capitalize on these opportunities. A primary part of this analysis was to characterize the quantity and energy value of the emissions. For example, in 2001, the industrial sector emitted 19% of the U.S. greenhouse gases (GHG) through its industrial processes and emitted 11% of GHG through electricity purchased from off-site utilities. Therefore, industry (not including agriculture) was directly and indirectly responsible for emitting 30% of the U.S. GHG. These emissions were mainly comprised of carbon dioxide (CO2), but also contained a wide-variety of CH4 (methane), CO (carbon monoxide), H2 (hydrogen), NMVOC (non-methane volatile organic compound), and other chemicals. As part of this study, we conducted a survey of publicly available literature to determine the amount of energy embedded in the emissions and to identify technology opportunities to capture and

  1. Thermal and economic analyses of a compact waste heat recovering system for the marine diesel engine using transcritical Rankine cycle

    Yang, Min-Hsiung

    2015-01-01

    Graphical abstract: Schematic diagram of the CWHRS for a marine diesel engine. - Highlights: • The economic optimization of a CWHRS of a marine engine is investigated. • The environmental protection refrigerant, R1234yf is used as the working fluid of the TRC system. • The optimal analysis and comparison of three models for waste heat recovering have been carried out. • The optimization of payback periods, CO_2 emission reducing and diesel oil saving are reported. - Abstract: The aim of this study is to investigate the economic performance of a novel compact waste heat recovering system for the marine diesel engine. The transcritical Rankine cycle is employed to convert the waste heat resources to useful work with R1234yf. To evaluate the utilizing efficiency and economic performance of waste heat resources, which are exhaust gas, cylinder cooling water and scavenge air cooling water, three operating models of the system are investigated and compared. The levelized energy cost, which represents the total cost per kilo-watt power, is employed to evaluate the economic performance of the system. The economic optimization and its corresponding optimal parameters of each operating model in the compact waste heat recovering system are obtained theoretically. The results show that the minimal levelized energy cost of the proposed system operated in Model I is the lowest of the three models, and then are Model II and Model III, which are 2.96% and 9.36% lower for, respectively. Similarly, the CO_2 emission reduction is the highest for Model I of the three models, and 21.6% and 30.1% lower are obtained for Model II and Model III, respectively. The compact waste heat recovering system operated in Model I has superiority on the payback periods and heavy diesel oil saving over the others. Finally, the correlations using specific work of working fluid and condensation temperature as parameters are proposed to assess the optimal conditions in economic performance

  2. Opportunity Analysis for Recovering Energy from Industrial Waste Heat and Emissions

    Viswanathan, V. V. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Davies, R. W. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Holbery, J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2006-04-01

    This report analyzes the opportunity to recover chemical emissions and thermal emissions from U.S. industry. It also analyzes the barriers and pathways to more effectively capitalize on these opportunities.

  3. Technique for recovering rare-earth metals from spent sintered Nd-Fe-B magnets without external heating

    Ryo Sasai

    2016-06-01

    Full Text Available To selectively recover rare-earth metals with higher purity from spent sintered Nd-Fe-B magnets without external heating, we investigated the mechano-chemical treatment of spent sintered Nd-Fe-B magnet powder with a reaction solution of HCl and (COOH2 at room temperature. The results of various experiments showed that the mechano-chemical treatment with HCl and (COOH2 is very effective for recovering the rare-earth metals contained in spent sintered Nd-Fe-B magnet powder; the recovery rate and purity of the rare-earth metals were 95.3 and 95.0 mass%, respectively, under optimal conditions ([HCl] = 0.2 mol/dm3 and [(COOH2] = 0.25 mol/dm3.

  4. Method of recovering oil from alum shales. [heating by electric currents

    Wennerstrom, K G

    1918-06-04

    A method of treating alum shale and other bituminous shales in order to extract oil et cetera, is characterized by bringing the shale to a temperature at which it melts, and at which the necessary amount of heat is transferred to the molten shale to be distilled. The patent claim is characterized by heating the shale by means of electric current. The patent has one additional claim.

  5. Technical Feasibility Evaluation on The Use of A Peltier Thermoelectric Module to Recover Automobile Exhaust Heat

    Sugiartha, N.; Sastra Negara, P.

    2018-01-01

    A thermoelectric module composes of integrated p-n semiconductors as hot and cold side junctions and uses Seebeck effect between them to function as a thermoelectric generator (TEG) to directly convert heat into electrical power. Exhaust heat from engines as otherwise wasted to the atmosphere is one of the heat sources freely available to drive the TEG. This paper evaluates technical feasibility on the use of a Peltier thermoelectric module for energy recovery application of such kind of waste heat. An experimental apparatus has been setup to simulate real conditions of automobile engine exhaust piping system. It includes a square section aluminium ducting, an aluminium fin heat sink and a TEC1 12706 thermoelectric module. A heater and a cooling fan are employed to simulate hot exhaust gas and ambient air flows, respectively. Electrical loading is controlled by resistors. Dependent variables measured during the test are cold and hot side temperatures, open and loaded circuit output voltages and electrical current. The test results revealed a promising application of the Peltier thermoelectric module for the engine exhaust heat recovery, though the loaded output power produced and loaded output voltage are still far lower than the commercially thermoelectric module originally purposed for the TEG application.

  6. 42 CFR 52b.9 - What is the right of the United States to recover Federal funds when facilities are not used for...

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false What is the right of the United States to recover... HEALTH CONSTRUCTION GRANTS § 52b.9 What is the right of the United States to recover Federal funds when... purposes authorized under the Act. (d) The right of recovery of the United States set forth in paragraph (a...

  7. An integrated appraisal of energy recovery options in the United Kingdom using solid recovered fuel derived from municipal solid waste.

    Garg, A; Smith, R; Hill, D; Longhurst, P J; Pollard, S J T; Simms, N J

    2009-08-01

    This paper reports an integrated appraisal of options for utilising solid recovered fuels (SRF) (derived from municipal solid waste, MSW) in energy intensive industries within the United Kingdom (UK). Four potential co-combustion scenarios have been identified following discussions with industry stakeholders. These scenarios have been evaluated using (a) an existing energy and mass flow framework model, (b) a semi-quantitative risk analysis, (c) an environmental assessment and (d) a financial assessment. A summary of results from these evaluations for the four different scenarios is presented. For the given ranges of assumptions; SRF co-combustion with coal in cement kilns was found to be the optimal scenario followed by co-combustion of SRF in coal-fired power plants. The biogenic fraction in SRF (ca. 70%) reduces greenhouse gas (GHG) emissions significantly ( approximately 2500 g CO(2) eqvt./kg DS SRF in co-fired cement kilns and approximately 1500 g CO(2) eqvt./kg DS SRF in co-fired power plants). Potential reductions in electricity or heat production occurred through using a lower calorific value (CV) fuel. This could be compensated for by savings in fuel costs (from SRF having a gate fee) and grants aimed at reducing GHG emission to encourage the use of fuels with high biomass fractions. Total revenues generated from coal-fired power plants appear to be the highest ( 95 pounds/t SRF) from the four scenarios. However overall, cement kilns appear to be the best option due to the low technological risks, environmental emissions and fuel cost. Additionally, cement kiln operators have good experience of handling waste derived fuels. The scenarios involving co-combustion of SRF with MSW and biomass were less favourable due to higher environmental risks and technical issues.

  8. An integrated appraisal of energy recovery options in the United Kingdom using solid recovered fuel derived from municipal solid waste

    Garg, A.; Smith, R.; Hill, D.; Longhurst, P.J.; Pollard, S.J.T.; Simms, N.J.

    2009-01-01

    This paper reports an integrated appraisal of options for utilising solid recovered fuels (SRF) (derived from municipal solid waste, MSW) in energy intensive industries within the United Kingdom (UK). Four potential co-combustion scenarios have been identified following discussions with industry stakeholders. These scenarios have been evaluated using (a) an existing energy and mass flow framework model, (b) a semi-quantitative risk analysis, (c) an environmental assessment and (d) a financial assessment. A summary of results from these evaluations for the four different scenarios is presented. For the given ranges of assumptions; SRF co-combustion with coal in cement kilns was found to be the optimal scenario followed by co-combustion of SRF in coal-fired power plants. The biogenic fraction in SRF (ca. 70%) reduces greenhouse gas (GHG) emissions significantly (∼2500 g CO 2 eqvt./kg DS SRF in co-fired cement kilns and ∼1500 g CO 2 eqvt./kg DS SRF in co-fired power plants). Potential reductions in electricity or heat production occurred through using a lower calorific value (CV) fuel. This could be compensated for by savings in fuel costs (from SRF having a gate fee) and grants aimed at reducing GHG emission to encourage the use of fuels with high biomass fractions. Total revenues generated from coal-fired power plants appear to be the highest ( Pounds 95/t SRF) from the four scenarios. However overall, cement kilns appear to be the best option due to the low technological risks, environmental emissions and fuel cost. Additionally, cement kiln operators have good experience of handling waste derived fuels. The scenarios involving co-combustion of SRF with MSW and biomass were less favourable due to higher environmental risks and technical issues.

  9. Heat stress assessment in artistic glass units.

    d'AMBROSIO Alfano, Francesca Romana; Palella, Boris Igor; Riccio, Giuseppe; Bartalini, Massimo; Strambi, Fabio; Malchaire, Jacques

    2018-04-07

    Heat stress in glass industry is mainly studied in large and highly mechanized manufacturing Units. To the contrary, few studies were carried out in small factories specialized in hand-made products. To stress the need of combined objective and medical surveys in these environments, this paper deals with a simultaneous climatic and physiological investigation of working conditions in artistic crystal glass factories in Tuscany (Italy). The microclimatic monitoring, through a continuous survey has been carried out in early spring. The main physiological parameters (metabolic rate, heart rate, tympanic temperature and water loss) were measured over the whole shifts. The results show that, despite the arduousness of the working conditions, the heat stress levels are physiologically tolerable. The predictions made using the PHS model at the Analysis level described in ISO 15265 agree closely to the observed values, validating the use of PHS model in these conditions. This model was then used to analyse what is likely to be the situation during the summer. It is concluded that the heat constraint will be very high and that some steps must be taken from the spring to monitor closely the exposed workers in the summer and take measures to prevent any heat accident.

  10. 21 CFR 890.5950 - Powered heating unit.

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Powered heating unit. 890.5950 Section 890.5950...) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Therapeutic Devices § 890.5950 Powered heating unit. (a) Identification. A powered heating unit is a device intended for medical purposes that...

  11. Heating great residential units with combustion-motor heat pumps

    Vossen, W

    1982-10-01

    Economic usage of combustion-motor heat pumps requires: reliable technology and delivery of the heat pump; design and operation. The heat pump must be integrated perfectly into the heating system. This contributions is based on a three-year operational experience with over 150 heat pumps used mainly in residential and administrative buildings (plus commercial buildings, swimming pools, sport centres etc.). These are heat pumps operating on the compression principle with natural gas, liquid gas, or fuel oil.

  12. Performance investigation on a multi-unit heat pump for simultaneous temperature and humidity control

    Fan, Hongming; Shao, Shuangquan; Tian, Changqing

    2014-01-01

    Highlights: • A multi-unit heat pump is proposed for simultaneous temperature and humidity control. • Condensation heat is non, partly or fully recovered for temperature regulation. • Highly integrated heat pump for residential cooling, dehumidification and heating. • High energy saving potential for all-year-round operation in wet and warm regions. - Abstract: A multi-unit heat pump is presented for simultaneous humidity and temperature control to improve the energy efficiency and the thermal comfort. Two parallel connected condensers are employed in the system, locating at the back of the indoor evaporator and the outdoor unit, respectively. The heat pump can operate in four modes, including heating, cooling and dehumidification without and/or with partial or total condensing heat recovery. The experimental investigation shows that the temperature control capacity is from 3.5 kW for cooling to 3.8 kW for heating with the cooling and heating efficiency higher than 3.5 kW kW −1 , and the dehumidification rate is about 2.0 kg h −1 with the efficiency about 2.0 kg h −1 kW −1 . The supply air temperature and humidity can be simultaneously regulated with high accuracy and high efficiency by adjusting the indoor and/or outdoor air volumes. It provides an integrated and effective solution for simultaneous indoor air temperature and humidity control for all-year-round operation in residential buildings

  13. Parametric Investigation and Thermoeconomic Optimization of a Combined Cycle for Recovering the Waste Heat from Nuclear Closed Brayton Cycle

    Lihuang Luo

    2016-01-01

    Full Text Available A combined cycle that combines AWM cycle with a nuclear closed Brayton cycle is proposed to recover the waste heat rejected from the precooler of a nuclear closed Brayton cycle in this paper. The detailed thermodynamic and economic analyses are carried out for the combined cycle. The effects of several important parameters, such as the absorber pressure, the turbine inlet pressure, the turbine inlet temperature, the ammonia mass fraction, and the ambient temperature, are investigated. The combined cycle performance is also optimized based on a multiobjective function. Compared with the closed Brayton cycle, the optimized power output and overall efficiency of the combined cycle are higher by 2.41% and 2.43%, respectively. The optimized LEC of the combined cycle is 0.73% lower than that of the closed Brayton cycle.

  14. Organic Rankine cycle unit for waste heat recovery on ships (PilotORC)

    Haglind, Fredrik; Montagud, Maria E. Mondejar; Andreasen, Jesper Graa

    The project PilotORC was aimed at evaluating the technical and economic feasibility of the use of organic Rankine cycle (ORC) units to recover low-temperature waste heat sources (i.e. exhaust gases, scavenge air, engine cooling system, and lubricant oil system) on container vessels. The project...... included numerical simulations and experimental tests on a 125 kW demonstration ORC unit that utilizes the waste heat of the main engine cooling system on board one of Mærsk's container vessels. During the design of the demonstration ORC unit, different alternatives for the condenser were analyzed in order...... of using ORC units for maritime applications, and the relevance of this technology for new-building projects. Firstly, an evaluation of the waste heat resources available on board Mærsk containers fleet, and an estimation of the potential energy recovery by means of the ORC technology was performed...

  15. Economic research of the transcritical Rankine cycle systems to recover waste heat from the marine medium-speed diesel engine

    Yang, Min-Hsiung; Yeh, Rong-Hua

    2017-01-01

    The aim of this study is to investigate the economic performance of a transcritical Rankine cycle (TRC) system for recovering waste heat from the exhaust gas of a marine medium-speed diesel engine. The variation of net power output, total cost of equipments and exergy destruction are investigated for the TRC system. Furthermore, to evaluate the economic performance of energy utilization, a parameter, net power output index, which is the ratio of net power output to the total cost, is introduced of the TRC system using R125, R143a, R218 and R1234yf as working fluids. The results show that R1234yf performs the highest economic performance, followed by R143a, R125 and R218 of the TRC system. It reveals that R1234yf not only has the smallest high and low pressures of the TRC system for reducing the purchased cost of equipments, but also promotes a larger pressure ratio of the expander for generating power output among these working fluids. The comparisons of optimal pressure ratios obtained from thermodynamic and economic optimizations for these working fluids in the TRC system are also reported. In addition, an evaluation method using thermal efficiency and operating pressure ratio as parameters is proposed to assess the suitability of the working fluids of TRC system in economic analysis for waste heat recovery from the exhaust gas of a diesel engine.

  16. Some performance characteristics of a fluidized bed heat recovery unit

    Militzer, J.; Basu, P.; Adaikkappan, N.

    1985-01-01

    The advantages of using fluidized bed heat recovery units with diesel engines are well documented. Two of those are: significantly less tube fouling and heat transfer coefficient four to five time higher than that of conventional shell and tube heat exchangers. The high concentration of soot in the exhaust gases of diesel engines make fouling a major concern in design of any kind of heat recovery unit. In the experiment a conventional fluidized bed heat exchanger was connected to the exhaust of a diesel engine mounted on a dynamometer. With this arrangement it was possible to test the heat recovery unit under a wide range of operating conditions. The main objective of this experiment was the determination of the performance characteristics of the heat recovery unit, especially with reference to its heat transfer and fouling characteristics. (author)

  17. Heat transfer unit and method for prefabricated vessel

    Tamburello, David A.; Kesterson, Matthew R; Hardy, Bruce J.

    2017-11-07

    Vessel assemblies, heat transfer units for prefabricated vessels, and methods for heat transfer prefabricated vessel are provided. A heat transfer unit includes a central rod, and a plurality of peripheral rods surrounding the central rod and connected to the central rod. The plurality of peripheral rods are movable between a first collapsed position and a second bowed position, wherein in the second bowed position a midpoint of each of the plurality of peripheral rods is spaced from the central rod relative to in the first position. The heat transfer unit further includes a heat transfer element connected to one of the plurality of peripheral rods.

  18. Thermodynamic investigation of waste heat driven desalination unit based on humidification dehumidification (HDH) processes

    He, W.F.; Xu, L.N.; Han, D.; Gao, L.; Yue, C.; Pu, W.H.

    2016-01-01

    Highlights: • HDH desalination system powered by waste heat is proposed. • Performance of the desalination unit and the relevant heat recovery effect is calculated. • Sensitive analysis of the performance for the HDH desalination system is investigated. • Mathematical model based on the first and second laws of thermodynamics is established. - Abstract: Humidification dehumidification (HDH) technology is an effective pattern to separate freshwater from seawater or brackish water. In this paper, a closed-air open-water (CAOW) desalination unit coupled with plate heat exchangers (PHEs) is applied to recover the waste heat from the gas exhaust. Sensitivity analysis for the HDH desalination unit as well as the PHEs from the key parameters including the top and initial temperature of the seawater, operation pressure, and the terminal temperature difference (TTD) of the PHEs are accomplished, and the corresponding performance of the whole HDH desalination system is calculated and presented. The simulation results show that the balance condition of the dehumidifier is allowed by the basic thermodynamic laws, followed by a peak value of gained-output-ratio (GOR) and a bottom value of total specific entropy generation. It is concluded that excellent results including the system performance, heat recovery effect and investment of the PHEs can be simultaneously obtained with a low top temperature, while the obtained desalination performance and the heat recovery effect from other measures are always conflicting. Different from other parameters of the desalination unit, the terminal temperature difference of the PHEs has little influences on the final value of GOR.

  19. EDF feedback on recent EPRI SGOG SG chemical cleanings applications for TSP blockage reduction and heat transfer recover

    Dijoux, M.; De Bouvier, O.; Mercier, S.; Pages, D.; Bretelle, J.-L.; Leclercq, P.; Mermillod, A.

    2010-01-01

    Between 2007 and 2008, six Steam Generators Chemical Cleanings (SGCC) with the inhibitor free high temperature process were applied on EDF PWR units. The main goal was to reduce the excessive Tube Support Plate blockages observed on several units of the EDF fleet and the consequences on wide range levels and the risk of tube cracks. The heat transfer recovery was the second objective. Despite the correct results obtained, the corrosion impact of the high temperature process on internal metallic surfaces, higher than expected, and the environmental issues led EDF to move to a new cleaning process. The low temperature process developed by EPRI SGOG and applied for many years was selected for the same purpose. Some qualification laboratory tests were performed by Dominion Engineering Inc (DEI) to demonstrate the innocuousness an the efficiency of the process to achieve these goals. The EPRI SGOG process was then applied seven times by Westinghouse on the EDF units Cruas 3, Cruas 2, Belleville 1, Cattenom 1, Cattenom 3, Chinon B3 and Cattenom 4 between 2008 and 2010. All these units operate from the initial start at low AVT pH 25 o C (9,2) in the secondary circuit. Due to copper presence in the deposits to remove, the cleaning sequence 'Copper - Iron - Copper steps' was performed each time. After a short description of the process, including the specific adaptation in France, lessons learned are reported in this paper in the following areas: process monitoring, corrosion, efficiency, liquid and gaseous wastes, chemical pollution during start-up. Based on the 3 first applications in 2008, some modifications of the process were implemented, particularly for the copper step. For the units cleaned, 1100 to 4500 kg of deposits per SG have been removed, including TS sludge lancing. The reduction of TSP blockages was satisfying. The effect on steam pressure improvement and the wide range level is then discussed. The paper concludes on EDF perspectives for soft

  20. Computer aided heat transfer analysis in a laboratory scaled heat exchanger unit

    Gunes, M.

    1998-01-01

    In this study. an explanation of a laboratory scaled heat exchanger unit and a software which is developed to analyze heat transfer. especially to use it in heat transfer courses, are represented. Analyses carried out in the software through sample values measured in the heat exchanger are: (l) Determination of heat transfer rate, logarithmic mean temperature difference and overall heat transfer coefficient; (2)Determination of convection heat transfer coefficient inside and outside the tube and the effect of fluid velocity on these; (3)Investigation of the relationship between Nusselt Number. Reynolds Number and Prandtl Number by using multiple non-linear regression analysis. Results are displayed on the screen graphically

  1. Consumer Unit for Low Energy District Heating Net

    Paulsen, Otto; Fan, Jianhua; Furbo, Simon

    2008-01-01

    to reduce heat loss in the network. The consumer’s installation is a unit type with an accumulation tank for smoothing the heat load related to the domestic hot water. The building heat load is delivered by an under-floor heating system. The heavy under-floor heating system is assumed to smooth the room...... heat load on a daily basis, having a flow temperature control based on outdoor climate. The unit is designed for a near constant district heating water flow. The paper describes two concepts. The analyses are based on TRNSYS (Klein et al., 2006) simulation, supplied with laboratory verification......A low energy/ low temperature consumer installation is designed and analyzed. The consumer type is a low energy single family house 145 m2 with annual energy consumption in the range of 7000 kWh, incl. domestic hot water in a 2800 degree day climate. The network is an extreme low temperature system...

  2. The role of heat pipes in intensified unit operations

    Reay, David; Harvey, Adam

    2013-01-01

    Heat pipes are heat transfer devices that rely, most commonly, on the evaporation and condensation of a working fluid contained within them, with passive pumping of the condensate back to the evaporator. They are sometimes referred to as ‘thermal superconductors’ because of their exceptionally high effective thermal conductivity (substantially higher than any metal). This, together with several other characteristics make them attractive to a range of intensified unit operations, particularly reactors. The majority of modern computers deploy heat pipes for cooling of the CPU. The application areas of heat pipes come within a number of broad groups, each of which describes a property of the heat pipe. The ones particularly relevant to chemical reactors are: i. Separation of heat source and sink. ii. Temperature flattening, or isothermalisation. iii. Temperature control. Chemical reactors, as a heat pipe application area, highlight the benefits of the heat pipe based on isothermalisation/temperature flattening device and on being a highly effective heat transfer unit. Temperature control, done passively, is also of relevance. Heat pipe technology offers a number of potential benefits to reactor performance and operation. The aim of increased yield of high purity, high added value chemicals means less waste and higher profitability. Other intensified unit operations, such as those employing sorption processes, can also profit from heat pipe technology. This paper describes several variants of heat pipe and the opportunities for their use in intensified plant, and will give some current examples. -- Highlights: ► Heat pipes – thermal superconductors – can lead to improved chemical reactor performance. ► Isothermalisation within a reactor vessel is an ideal application. ► The variable conductance heat pipe can control reaction temperatures within close limits. ► Heat pipes can be beneficial in intensified reactors

  3. Low Temperature District Heating Consumer Unit with Micro Heat Pump for Domestic Hot Water Preparation

    Zvingilaite, Erika; Ommen, Torben Schmidt; Elmegaard, Brian

    2012-01-01

    In this paper we present and analyse the feasibility of a district heating (DH) consumer unit with micro heat pump for domestic hot water (DHW) preparation in a low temperature (40 °C) DH network. We propose a micro booster heat pump of high efficiency (COP equal to 5,3) in a consumer DH unit...... in order to boost the temperature of the district heating water for heating the DHW. The paper presents the main designs of the suggested system and different alternative micro booster heat pump concepts. Energy efficiency and thermodynamic performance of these concepts are calculated and compared....... The results show that the proposed system has the highest efficiency. Furthermore, we compare thermodynamic and economic performance of the suggested heat pump-based concept with different solutions, using electric water heater. The micro booster heat pump system has the highest annualised investment (390 EUR...

  4. Manufacturing A Refrigerator with Heat Recovery Unit

    Mustafa Mohammed Kadhim

    2018-02-01

    Full Text Available This study aims to exploite the rejected heating energy from condenser and benefit from it to reheat the foods and other materials. It can also be employed to improve the coefficient of performance of a refrigerator at the same time by using approximately the same consumption electrical energy used to operate the compressor and refrigerator in general. This idea has been implemented by manufacturing of a refrigerator with using additional part has the same metal and condenser pipe diameters but its surface area does not exceed 40% from total surface area of the condenser and its design as an insulated cabinet from all sides to prevent heat leakage through it and located between the compressor and the condenser. Small electrical fan has been added inside this cabinet to provide a suitable air circulation and a homogenous temperature distribution inside the cabinet space. It is expected that the super heating energy of refrigerant (R134a which comes out of the compressor would be removed  inside this cabinet and this insist to condensate the refrigerant (cooling fluid with a rate higher than that used in the normal refrigerator only. Three magnetic valves have been used in order to control the refrigerant flow in state of operation the refrigerator only or to gather with heating cabinet. To measure the temperatures at each process of the simple vapor compression refrigeration cycle, nine temperature sensors at input and output of each compressor, condenser and an evaporator in additional to input of cabinet and inside it and on evaporator surface have been provided. Five pressure gages have been used to measure the value of pressure and compare it for the two states of operation. The consumption of electrical energy  can be calculated by adding an ammeter and a voltmeter and compare between the consumption energy of both states. The obtained results show that there is an improvement in the coeffecient of performance in state of operation the

  5. Method of recovering deeply submerged support strings of a self-lifting floating unit from the ground

    Dzhafarov, A M; Leybenzon, S R; Sarkisov, V G

    1982-01-01

    A method is proposed for recovering from the ground deeply submerged strings of self-lifting floating unit consisting of application of vertical forces through a lifter to the support string from surplus buoyancy of the housing submerged into the water. It is distinguished by the fact that in order to improve reliability and to expand the area of operation in water areas with deep occurrence of the bearing ground, submersion of the housing is done with its inclination. This applies to the support string or a group of support strings a permissible momentum, after which water ballast is used towards the housing opposite the inclined, with simultaneous preservation of the permissible moment applied to the support string or group of support strings, and the permissible momentum is determined from the formula-..mu.. = ..sqrt..theta/sup 2/ + /PSI//sup 2//A where M--momentum permitted according to the conditions of strength of the support string; /PSI/--angle of trim; /ETA/-- angle of list; A--coefficient of flexibility of the string submerged into the ground.

  6. Heating unit of Berovo by co-generation (Macedonia)

    Armenski, Slave; Dimitrov, Konstantin; Tashevski, Done

    1999-01-01

    A plant for combined heat and electric power production, for central heating of the town Berovo (Macedonia) is proposed. The common reason to use a co-generation unit is the energy efficiency and a significant reduction of environmental pollution. The heat consumption of town Berovo is analyzed and determined. Based on the energy consumption of a whole power plant, e. i. the plant for combined and simultaneous production of power is proposed. The quantity of annually heat and electrical production and annually coal consumption are estimated. (Author)

  7. Analyzing the optimization of an organic Rankine cycle system for recovering waste heat from a large marine engine containing a cooling water system

    Yang, Min-Hsiung; Yeh, Rong-Hua

    2014-01-01

    Highlights: • Employing the thermodynamic analysis and a heat-transfer method, an ORC optimization is presented. • An optimal objective parameter evaluation of six working fluids is presented. • Refrigerants with superior thermodynamic properties do not necessary have excellent performance. • Cylinder jacket water temperature strongly affects optimal evaporation temperature. - Abstract: In this study, six working fluids with zero ozone depletion potential and low global warming potential are used in an organic Rankine cycle (ORC) system to recover waste heat from cylinder jacket water of large marine diesel engines. Thermodynamic analysis and a finite-temperature-difference heat-transfer method are developed to evaluate the thermal efficiency, total heat-exchanger area, objective parameter, and exergy destruction of the ORC system. The optimal evaporation and condensation temperatures for achieving the maximal objective parameter, the ratio of net power output to the total heat-transfer area of heat exchangers, of an ORC system are investigated. The results show that, among the working fluids, R600a performs the best in the optimal objective parameter evaluation followed by R1234ze, R1234yf, R245fa, R245ca, and R1233zd at evaporation temperatures ranging from 58 °C to 68 °C and condensation temperatures ranging from 35 °C to 45 °C. The optimal operating temperatures and corresponding thermal efficiency and exergy destruction are proposed. Furthermore, the influences of inlet temperatures on cylinder jacket water and cooling water in the ORC are presented for recovering waste heat. The results of this work were verified with theoretical solutions and experimental results in the literature and it was revealed that they were consistent with them

  8. Heat pipes and heat pipe exchangers for heat recovery systems

    Vasiliev, L L; Grakovich, L P; Kiselev, V G; Kurustalev, D K; Matveev, Yu

    1984-01-01

    Heat pipes and heat pipe exchangers are of great importance in power engineering as a means of recovering waste heat of industrial enterprises, solar energy, geothermal waters and deep soil. Heat pipes are highly effective heat transfer units for transferring thermal energy over large distance (tens of meters) with low temperature drops. Their heat transfer characteristics and reliable working for more than 10-15 yr permit the design of new systems with higher heat engineering parameters.

  9. Outdoor unit construction for an electric heat pump

    Draper, R.; Lackey, R.S.

    1984-09-11

    The outdoor unit for an electric heat pump is provided with an upper portion containing propeller fan means for drawing air through the lower portion containing refrigerant coil means in the form of four discrete coils connected together in a subassembly forming a W shape, the unit being provided with four adjustable legs which are retracted in shipment, and are adjusted on site to elevate the unit to a particular height suitable for the particular location in which the unit is installed. 4 figs.

  10. A New Approach for Heating the Plastics Injection Units

    Virgilius Vasilache

    2010-06-01

    Full Text Available The plastics injection molding machines are one of the most eager consumers of energy. The plasticizing unit itself is the most important energetic consumer among the subassemblies of these machines; that is why this subassembly is the target of most actions of consumption decreasing on such machines. Our concerns on this direction got the shape of developing a new heating system for the plasticizing unit, which system was already patented [1].

  11. The urban heat island dynamics during heat waves: a study of cities in the United States

    Hu, Leiqiu

    2016-04-01

    The urban heat island (UHI) is a common phenomenon describing that metropolitan areas are usually warmer than their rural surroundings. This effect is compounded by extreme heat events, which are a leading cause of weather-related human mortality in many countries worldwide. However, the spatial and diurnal variability of temperature and humidity in urban and adjacent rural areas during extreme heat events is not well measured and therefore not well understood. The recently developed dataset of near-surface air and dew temperature from MODIS atmospheric profiles and the new method for the UHI quantification--urban heat island curve are used to quantify the urban climatic changes during heat waves in cities of the United States. The enhanced and weakened UHIs are observed in various cities. The causes of UHI changes during heat waves are discussed, including climate region, vegetation type and amount, city geolocation, etc.

  12. Sustainability assessment of heat exchanger units for spray dryers

    Caglayan, Hasan; Caliskan, Hakan

    2017-01-01

    In this study, the sustainability assessment is performed to the system known as heat exchanger unit with spray dryer. The five-different dead state temperatures (0-5-10-15-20 °C) are considered. It is found that the heat exchanger has the highest energy efficiency (63.32%), while the overall system has the lowest one (5.56%). So, the combination of the spray dryer with the heat exchanger is more effective. On the other hand, the overall exergy efficiency of the system is lower than the heat exchanger and spray dryer for all of the dead state (environmental) temperatures. The exergy efficiency of the heat exchanger is inversely proportional to the dead state temperature, and the maximum rate is found as 49.65% at 0 °C. Furthermore, the exergy efficiencies of the spray dryer and overall system are directly proportional to the dead state temperatures, and the corresponding maximum rates are found to be 26.41% and 24.32% at 20 °C, respectively. Also, the exergy destruction is directly proportional to the dead state temperatures. The minimum and maximum exergy destruction rates are found at the dead state temperatures of 0 °C and 20 °C, respectively. Furthermore, the most sustainable system is found as the heat exchanger unit. - Highlights: • Thermodynamic analyses of industrial heat exchangers and spray dryers. • Sustainability of heat exchangers for spray dryers. • Dead state temperature effects on exergy efficiencies of heat exchangers and spray dryers.

  13. Recovering hydrogen production performance of upflow anaerobic sludge blanket reactor (UASBR) fed with galactose via repeated heat treatment strategy.

    Sivagurunathan, Periyasamy; Anburajan, Parthiban; Kumar, Gopalakrishnan; Park, Jong-Hun; Kim, Sang-Hyoun

    2017-09-01

    This study evaluated the effect of repeated heat treatment towards the enhancement of hydrogen fermentation from galactose in an upflow anaerobic sludge blanket reactor with the hydraulic retention time of 6h and the operation temperature of 37°C. The hydrogen production rate (HPR) and hydrogen yield (HY) gradually increased up to 9.1L/L/d and 1.1mol/mol galactose, respectively, until the 33rd day of operation. When heat treatment at 80°C for 30min was applied, hydrogen production performance was enhanced by 37% with the enrichment of hydrogen producing bacteria population. The HPR and HY were achieved at 12.5L/L/d and 1.5mol/mol hexose, respectively, during further 30 cycles of reactor operation. The repeated heat treatment would be a viable strategy to warrant reliable continuous hydrogen production using mixed culture. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Airflow and Heat Transfer in the Slot-Vented Room with Radiant Floor Heating Unit

    Xiang-Long Liu

    2012-01-01

    Full Text Available Radiant floor heating has received increasing attention due to its diverse advantages, especially the energy saving as compared to the conventional dwelling heating system. This paper presents a numerical investigation of airflow and heat transfer in the slot-vented room with the radiant floor heating unit. Combination of fluid convection and thermal radiation has been implemented through the thermal boundary conditions. Spatial distributions of indoor air temperature and velocity, as well as the heat transfer rates along the radiant floor and the outer wall, have been presented and analyzed covering the domains from complete natural convection to forced convection dominated flows. The numerical results demonstrate that the levels of average temperature in the room with lateral slot-ventilation are higher than those without slot-ventilation, but lower than those in the room with ceiling slot-ventilation. Overall, the slot-ventilation room with radiant floor heating unit could offer better indoor air quality through increasing the indoor air temperature and fresh air exchanging rate simultaneously. Concerning the airborne pollutant transports and moisture condensations, the performance of radiant floor heating unit will be further optimized in our future researches.

  15. Heat recovery from UPS units - Analysis of a first unit and technology assessment; Waermerueckgewinnung in USV-Anlagen. Analyse einer Erstanlage und Potentialabschaetzung

    Stahl, S.; Schlegel, A.

    2009-11-15

    UPS units (uninterruptible power supply) generate large heat losses, which have to be dissipated with cooling units. awtec has developed a unique UPS system with integrated heat recovery which was installed in 2001 (Building Gretag/SAP in Regensdorf) and which is still running error-free. With this system the waste heat can be recovered and electrical energy for the refrigeration system can be saved likewise. The measured data shows that during the heating season, the unit transfers virtually all heat loss (about 20 MWh/year) to the space heating system. The building's refrigeration system, however, has its own heat recovery system, so the actual annual energy savings can be estimated to be only about 4 MWh of electricity. The prototype shows that awtec built a robust unit which - given an appropriate cooling and heating system - has the potential for high energy savings (without central heat recovery system: 4 MWh electric + 20 MWh thermal) without increased investment. Based on the UPS heat recovery development, previous projects of the Swiss Federal Office of Energy and a market survey, scenarios for the cooling and heat recovery from UPS units were developed. Since the same concepts also apply to the cooling of servers and other IT components, they were also included in the analysis. The scenario analysis shows that a high potential for savings of electric energy and heat exists in this area. In particular, the direct cooling of the IT components with cooling water offers big benefits for heat recovery and free cooling (cooling without the use of the refrigeration system) compared to conventional air cooling. These direct cooling systems are currently mainly used for special applications or as a fallback in case of overheating problems. Passive cooling through geothermal probes, which are now mainly used for buildings with small heat pump systems, provides an interesting approach to the cooling of IT equipment in accordance with the temperature level. It

  16. Empirical Analysis for the Heat Exchange Effectiveness of a Thermoelectric Liquid Cooling and Heating Unit

    Hansol Lim

    2018-03-01

    Full Text Available This study aims to estimate the performance of thermoelectric module (TEM heat pump for simultaneous liquid cooling and heating and propose empirical models for predicting the heat exchange effectiveness. The experiments were conducted to investigate and collect the performance data of TEM heat pump where the working fluid was water. A total of 57 sets of experimental data were statistically analyzed to estimate the effects of each independent variable on the heat exchange effectiveness using analysis of variance (ANOVA. To develop the empirical model, the six design parameters were measured: the number of transfer units (NTU of the heat exchangers (i.e., water blocks, the inlet water temperatures and temperatures of water blocks at the cold and hot sides of the TEM. As a result, two polynomial equations predicting heat exchange effectiveness at the cold and hot sides of the TEM heat pump were derived as a function of the six selected design parameters. Also, the proposed models and theoretical model of conventional condenser and evaporator for heat exchange effectiveness were compared with the additional measurement data to validate the reliability of the proposed models. Consequently, two conclusions have been made: (1 the possibility of using the TEM heat pump for simultaneous cooling and heating was examined with the maximum temperature difference of 30 °C between cold and hot side of TEM, and (2 it is revealed that TEM heat pump has difference with the conventional evaporator and condenser from the comparison results between the proposed models and theoretical model due to the heat conduction and Joule effect in TEM.

  17. Characterization of heat emission of light-curing units.

    Wahbi, Mohammed A; Aalam, F A; Fatiny, F I; Radwan, S A; Eshan, I Y; Al-Samadani, K H

    2012-04-01

    This study was designed to analyze the heat emissions produced by light-curing units (LCUs) of different intensities during their operation. The null hypothesis was that the tested LCUs would show no differences in their temperature rises. FIVE COMMERCIALLY AVAILABLE LCUS WERE TESTED: a "Flipo" plasma arc, "Cromalux 100" quartz-tungsten-halogen, "L.E. Demetron 1" second-generation light-emitting diode (LED), and "Blue Phase C5" and "UltraLume 5" third-generation LED LCUs. The intensity of each LCU was measured with two radiometers. The temperature rise due to illumination was registered with a type-K thermocouple, which was connected to a computer-based data acquisition system. Temperature changes were recorded in continues 10 and 20 s intervals up to 300 s. The Flipo (ARC) light source revealed the highest mean heat emission while the L.E. Demetron 1 LED showing the lowest mean value at 10 and 20 s exposure times. Moreover, Cromalux (QTH) recorded the second highest value for all intervals (12.71, 14.63, 14.60) of heat emission than Blue Phase C5 (LED) (12.25, 13.87, 13.69), interestingly at 20 s illumination for all intervals the highest results (18.15, 19.27, 20.31) were also recorded with Flipo (PAC) LCU, and the lowest (6.71, 5.97, 5.55) with L.E. Demetron 1 LED, while Blue Phase C5 (LED) recorded the second highest value at the 1st and 2nd 20 s intervals (14.12, 11.84, 10.18) of heat emission than Cromalux (QTH) (12.26, 11.43, 10.26). The speed of temperature or heat rise during the 10 and 20 s depends on light intensity of emitted light. However, the QTH LCU was investigated resulted in a higher temperature rise than LED curing units of the same power density. The PAC curing unit induced a significantly higher heat emission and temperature increase in all periods, and data were statistically different than the other tested groups (p < .05). LED (Blue Phase C5) was not statistically significant (p < .05) (at 10 s) than QTH units, also LED (Blue

  18. A heated vapor cell unit for DAVLL in atomic rubidium

    McCarron, Daniel J.; Hughes, Ifan G.; Tierney, Patrick; Cornish, Simon L.

    2007-01-01

    The design and performance of a compact heated vapor cell unit for realizing a dichroic atomic vapor laser lock (DAVLL) for the D2 transitions in atomic rubidium is described. A 5 cm-long vapor cell is placed in a double-solenoid arrangement to produce the required magnetic field; the heat from the solenoid is used to increase the vapor pressure and correspondingly the DAVLL signal. We have characterized experimentally the dependence of important features of the DAVLL signal on magnetic field...

  19. Heat recovery unit operation of HVAC system in IMEF

    Paek, S. R.; Oh, Y. W.; Song, E. S.; Park, D. K.; Joo, Y. S.; Hong, K. P.

    2003-01-01

    HVAC system including a supply and exhaust air system in IMEF(Irradiated Materials Examination Facility) is an essential facility for preventing a leakage of radioactive materials and for a preservation of a working environment. It costs a lot to operate the HVAC system in IMEF because our ventilation type is once-through system, and an air flow is maintained from low level contamination area to high level and maintained high turns of ventilation air under certain conditions. As HRU(Heat Recovery Unit) at HVAC system based on PIEF(Post Irradiation Examination Facility) operation experiences is designed and adopted, it prevents from a heating coil freezing destruction in winter and makes much energy saving etc.. Heat pipe type HRU is adopted in IMEF, and a construction and operation result of HRU is examined

  20. HEAT ENGINEERING TESTING OF AIR COOLING UNIT OF HORIZONTAL TYPE

    Rohachov, Valerii Andriiovych; Semeniako, Oleksandr Volodymyrovych; Лазоренко, Р. О.; Середа, Р. М.; Parafeinyk, Volodymyr Petrovych

    2018-01-01

    The results of the thermal tests of the section of air cooler, the heat-exchange surface of which is made up of chess package of bimetal finned tubes are presented. The methods of research are presented, the experimental stand is described, the measurement errors are given. The efficiency of the experimental stand and the accuracy of the experimental data on it are confirmed. Proposed to use the stand for researches of air cooling units with other types and sections of finned tubes.

  1. Part-Load Performance Prediction and Operation Strategy Design of Organic Rankine Cycles with a Medium Cycle Used for Recovering Waste Heat from Gaseous Fuel Engines

    Xuan Wang

    2016-07-01

    Full Text Available The Organic Rankine Cycle (ORC is regarded as a suitable way to recover waste heat from gaseous fuel internal combustion engines. As waste heat recovery systems (WHRS have always been designed based on rated working conditions, while engines often work under part-load conditions, it is quite significant to analyze the part-load performance and corresponding operation strategy of ORC systems. This paper presents a dynamic model of ORC with a medium cycle used for a large gaseous fuel engine and analyzes the effect of adjustable parameters on the system performance, giving effective control directions under various conditions. The results indicate that the intermediary fluid mass flow rate has nearly no effect on the output power and thermal efficiency of the ORC, while the mass flow rate of working fluid has a great effect on them. In order to get a better system performance under different working conditions, the system should be operated with the working fluid mass flow rate as large as possible, but with a slight degree of superheating. Then, with the control of constant superheat degree at the end of the heating process, the performance of the combined system that consists of ORC and the engine at steady state under seven typical working conditions is also analyzed. The results indicate that the energy-saving effect of WHRS becomes worse and worse as the working condition decreases. Especially at 40% working condition the WHRS nearly has no energy-saving effect anymore.

  2. Comparison of the heat generation of light curing units.

    Bagis, Bora; Bagis, Yildirim; Ertas, Ertan; Ustaomer, Seda

    2008-02-01

    The aim of this study was to evaluate the heat generation of three different types of light curing units. Temperature increases were recorded from a distance of 1 mm from a thermocouple to the tip of three different types of light curing units including one quartz-tungsten halogen (QTH), one plasma arc (PAC), and one light emitting diode (LED) unit. An experimental model was designed to fix the 1 mm distance between the tip of the light curing units and the thermocouple wire. Temperature changes were recorded in 10 second intervals up to 40 seconds. (10, 20, 30, and 40 seconds). Temperature measurements were repeated three times for every light curing unit after a one hour standby period. Statistical analysis of the results was performed using the analysis of variance (ANOVA) and the Bonferroni Test. The highest temperature rises (54.4+/-1.65 degrees C) occurred during activation of a PAC light curing unit for every test period (pdamage to the pulp.

  3. Carbapenemase-Producing Enterobacteriaceae Recovered from the Environment of a Swine Farrow-to-Finish Operation in the United States.

    Mollenkopf, Dixie F; Stull, Jason W; Mathys, Dimitria A; Bowman, Andrew S; Feicht, Sydnee M; Grooters, Susan V; Daniels, Joshua B; Wittum, Thomas E

    2017-02-01

    Carbapenem-resistant Enterobacteriaceae (CRE) present an urgent threat to public health. While use of carbapenem antimicrobials is restricted for food-producing animals, other β-lactams, such as ceftiofur, are used in livestock. This use may provide selection pressure favoring the amplification of carbapenem resistance, but this relationship has not been established. Previously unreported among U.S. livestock, plasmid-mediated CRE have been reported from livestock in Europe and Asia. In this study, environmental and fecal samples were collected from a 1,500-sow, U.S. farrow-to-finish operation during 4 visits over a 5-month period in 2015. Samples were screened using selective media for the presence of CRE, and the resulting carbapenemase-producing isolates were further characterized. Of 30 environmental samples collected from a nursery room on our initial visit, 2 (7%) samples yielded 3 isolates, 2 sequence type 218 (ST 218) Escherichia coli and 1 Proteus mirabilis, carrying the metallo-β-lactamase gene bla IMP-27 on IncQ1 plasmids. We recovered on our third visit 15 IMP-27-bearing isolates of multiple Enterobacteriaceae species from 11 of 24 (46%) environmental samples from 2 farrowing rooms. These isolates each also carried bla IMP-27 on IncQ1 plasmids. No CRE isolates were recovered from fecal swabs or samples in this study. As is common in U.S. swine production, piglets on this farm receive ceftiofur at birth, with males receiving a second dose at castration (≈day 6). This selection pressure may favor the dissemination of bla IMP-27 -bearing Enterobacteriaceae in this farrowing barn. The absence of this selection pressure in the nursery and finisher barns likely resulted in the loss of the ecological niche needed for maintenance of this carbapenem resistance gene. Copyright © 2017 American Society for Microbiology.

  4. Possibility of using adsorption refrigeration unit in district heating network

    Grzebielec, Andrzej; Rusowicz, Artur; Jaworski, Maciej; Laskowski, Rafał

    2015-09-01

    Adsorption refrigeration systems are able to work with heat sources of temperature starting with 50 °C. The aim of the article is to determine whether in terms of technical and economic issues adsorption refrigeration equipment can work as elements that produce cold using hot water from the district heating network. For this purpose, examined was the work of the adsorption air conditioning equipment cooperating with drycooler, and the opportunities offered by the district heating network in Warsaw during the summer. It turns out that the efficiency of the adsorption device from the economic perspective is not sufficient for production of cold even during the transitional period. The main problem is not the low temperature of the water supply, but the large difference between the coefficients of performance, COPs, of adsorption device and a traditional compressor air conditioning unit. When outside air temperature is 25 °C, the COP of the compressor type reaches a value of 4.49, whereas that of the adsorption device in the same conditions is 0.14. The ratio of the COPs is 32. At the same time ratio between the price of 1 kWh of electric power and 1 kWh of heat is only 2.85. Adsorption refrigeration equipment to be able to compete with compressor devices, should feature COPads efficiency to be greater than 1.52. At such a low driving temperature and even changing the drycooler into the evaporative cooler it is not currently possible to achieve.

  5. Linking Excessive Heat with Daily Heat-Related Mortality over the Coterminous United States

    Quattrochi, Dale A.; Crosson, William L.; Al-Hamdan, Mohammad Z.; Estes, Maurice G., Jr.

    2014-01-01

    In the United States, extreme heat is the most deadly weather-related hazard. In the face of a warming climate and urbanization, which contributes to local-scale urban heat islands, it is very likely that extreme heat events (EHEs) will become more common and more severe in the U.S. This research seeks to provide historical and future measures of climate-driven extreme heat events to enable assessments of the impacts of heat on public health over the coterminous U.S. We use atmospheric temperature and humidity information from meteorological reanalysis and from Global Climate Models (GCMs) to provide data on past and future heat events. The focus of research is on providing assessments of the magnitude, frequency and geographic distribution of extreme heat in the U.S. to facilitate public health studies. In our approach, long-term climate change is captured with GCM outputs, and the temporal and spatial characteristics of short-term extremes are represented by the reanalysis data. Two future time horizons for 2040 and 2090 are compared to the recent past period of 1981- 2000. We characterize regional-scale temperature and humidity conditions using GCM outputs for two climate change scenarios (A2 and A1B) defined in the Special Report on Emissions Scenarios (SRES). For each future period, 20 years of multi-model GCM outputs are analyzed to develop a 'heat stress climatology' based on statistics of extreme heat indicators. Differences between the two future and the past period are used to define temperature and humidity changes on a monthly time scale and regional spatial scale. These changes are combined with the historical meteorological data, which is hourly and at a spatial scale (12 km) much finer than that of GCMs, to create future climate realizations. From these realizations, we compute the daily heat stress measures and related spatially-specific climatological fields, such as the mean annual number of days above certain thresholds of maximum and minimum air

  6. Studies on split heat pipe type adsorption ice-making test unit for fishing boats: Choice of heat pipe medium and experiments under unsteady heating sources

    Wang, L.W.; Wang, R.Z.; Lu, Z.S.; Chen, C.J.

    2006-01-01

    The split heat pipe type compound adsorption ice maker for fishing boats not only has the advantage of large volume cooling density but also has the advantage of less power consumption and high heat transfer performance. The available heat pipe media for the split heat pipe type compound adsorption ice maker, which are methanol, acetone and water are studied and compared in this paper, and the heat pipe medium of water shows the better performance for the reason of its stable heating and cooling process and high heat transfer performance. Considering the waste heat recovered from the diesel engine on fishing boats varies when the velocity of the fishing boat changes, the refrigeration performances at the condition of different values of heating power are studied while water is used as the heat pipe medium. Results show that the cooling power, as while as COP and SCP decrease when the heating power decreases. The highest COP and SCP are 0.41 and 731 W/kg, respectively, at the highest heating power of 4.2 kW, and the values decrease by 22% and 33%, respectively, when the heating power decreases by 15%. The values decrease by 32% and 51%, respectively, when the heating power decreases by 30%. The performance of the adsorption ice maker for the fishing boat with the 6160A type diesel engine is estimated, and the results show that the cooling power and ice productivity are as high as 5.44 kW and 1032 kg ice per day, respectively, even if the recovered waste heat decreases by 30% compared with the normal value. It can satisfy the ice requirements of such a fishing boat

  7. Population and Whole Genome Sequence Based Characterization of Invasive Group A Streptococci Recovered in the United States during 2015

    Sopio Chochua

    2017-09-01

    Full Text Available Group A streptococci (GAS are genetically diverse. Determination of strain features can reveal associations with disease and resistance and assist in vaccine formulation. We employed whole-genome sequence (WGS-based characterization of 1,454 invasive GAS isolates recovered in 2015 by Active Bacterial Core Surveillance and performed conventional antimicrobial susceptibility testing. Predictions were made for genotype, GAS carbohydrate, antimicrobial resistance, surface proteins (M family, fibronectin binding, T, R28, secreted virulence proteins (Sda1, Sic, exotoxins, hyaluronate capsule, and an upregulated nga operon (encodes NADase and streptolysin O promoter (Pnga3. Sixty-four M protein gene (emm types were identified among 69 clonal complexes (CCs, including one CC of Streptococcus dysgalactiae subsp. equisimilis. emm types predicted the presence or absence of active sof determinants and were segregated into sof-positive or sof-negative genetic complexes. Only one “emm type switch” between strains was apparent. sof-negative strains showed a propensity to cause infections in the first quarter of the year, while sof+ strain infections were more likely in summer. Of 1,454 isolates, 808 (55.6% were Pnga3 positive and 637 (78.9% were accounted for by types emm1, emm89, and emm12. Theoretical coverage of a 30-valent M vaccine combined with an M-related protein (Mrp vaccine encompassed 98% of the isolates. WGS data predicted that 15.3, 13.8, 12.7, and 0.6% of the isolates were nonsusceptible to tetracycline, erythromycin plus clindamycin, erythromycin, and fluoroquinolones, respectively, with only 19 discordant phenotypic results. Close phylogenetic clustering of emm59 isolates was consistent with recent regional emergence. This study revealed strain traits informative for GAS disease incidence tracking, outbreak detection, vaccine strategy, and antimicrobial therapy.

  8. Solid recovered fuels in the cement industry--semi-automated sample preparation unit as a means for facilitated practical application.

    Aldrian, Alexia; Sarc, Renato; Pomberger, Roland; Lorber, Karl E; Sipple, Ernst-Michael

    2016-03-01

    One of the challenges for the cement industry is the quality assurance of alternative fuel (e.g., solid recovered fuel, SRF) in co-incineration plants--especially for inhomogeneous alternative fuels with large particle sizes (d95⩾100 mm), which will gain even more importance in the substitution of conventional fuels due to low production costs. Existing standards for sampling and sample preparation do not cover the challenges resulting from these kinds of materials. A possible approach to ensure quality monitoring is shown in the present contribution. For this, a specially manufactured, automated comminution and sample divider device was installed at a cement plant in Rohožnik. In order to prove its practical suitability with methods according to current standards, the sampling and sample preparation process were validated for alternative fuel with a grain size >30 mm (i.e., d95=approximately 100 mm), so-called 'Hotdisc SRF'. Therefore, series of samples were taken and analysed. A comparison of the analysis results with the yearly average values obtained through a reference investigation route showed good accordance. Further investigations during the validation process also showed that segregation or enrichment of material throughout the comminution plant does not occur. The results also demonstrate that compliance with legal standards regarding the minimum sample amount is not sufficient for inhomogeneous and coarse particle size alternative fuels. Instead, higher sample amounts after the first particle size reduction step are strongly recommended in order to gain a representative laboratory sample. © The Author(s) 2016.

  9. Possibility of using adsorption refrigeration unit in district heating network

    Grzebielec Andrzej

    2015-09-01

    Full Text Available Adsorption refrigeration systems are able to work with heat sources of temperature starting with 50 °C. The aim of the article is to determine whether in terms of technical and economic issues adsorption refrigeration equipment can work as elements that produce cold using hot water from the district heating network. For this purpose, examined was the work of the adsorption air conditioning equipment cooperating with drycooler, and the opportunities offered by the district heating network in Warsaw during the summer. It turns out that the efficiency of the adsorption device from the economic perspective is not sufficient for production of cold even during the transitional period. The main problem is not the low temperature of the water supply, but the large difference between the coefficients of performance, COPs, of adsorption device and a traditional compressor air conditioning unit. When outside air temperature is 25 °C, the COP of the compressor type reaches a value of 4.49, whereas that of the adsorption device in the same conditions is 0.14. The ratio of the COPs is 32. At the same time ratio between the price of 1 kWh of electric power and 1 kWh of heat is only 2.85. Adsorption refrigeration equipment to be able to compete with compressor devices, should feature COPads efficiency to be greater than 1.52. At such a low driving temperature and even changing the drycooler into the evaporative cooler it is not currently possible to achieve.

  10. Experimental investigations on cylindrical latent heat storage units with sodium acetate trihydrate composites utilizing supercooling

    Dannemand, Mark; Johansen, Jakob Berg; Kong, Weiqiang

    2016-01-01

    Latent heat storage units utilizing stable supercooling of sodium acetate trihydrate (SAT) composites were tested in a laboratory. The stainless steel units were 1.5 m high cylinders with internal heat exchangers of tubes with fins. One unit was tested with 116 kg SAT with 6% extra water. Another...... in the thickened phase change material after melting. The heat content in the fully charged state and the heat released after solidification of the supercooled SAT mixtures at ambient temperature was higher for the unit with the thickened SAT mixture. The heat discharged after solidification of the supercooled SAT...

  11. Recovering oil from shale

    Leahey, T; Wilson, H

    1920-11-13

    To recover oil free from inorganic impurities and water, and utilize the oil vapor and tarry matter for the production of heat, shale is heated in a retort at a temperature of not less than 120/sup 0/C. The vapors pass by a pipe into a water jacketed condenser from which the condensate and gas pass through a pipe into a chamber and then by a pipe to a setting chamber from where the light oils are decanted through a pipe into a tank. The heavy oil is siphoned through a pipe into a tank, while the gas passes through a pipe into a scrubber and then into a drier, exhauster and pipe to the flue and ports, above the fire-bars, into the retort. Air is introduced through a pipe, flue, and ports.

  12. Design and operation of gas-heated thermal pumping units

    Rostek, H A [Ruhrgas A.G., Essen (Germany, F.R.)

    1979-03-01

    The first gas heat pump systems have been operated since spring 1977. These are applied in living houses, school, swimming pools, and sport places and administration buildings. The heating performance of these systems is 150-3800 kW. Two of these systems, one in a swimming pool and one in a house for several families are operating, each of them for one heating period. The operational experiences with these gas heat pumps are reported on, basing on measurement results. The experience gathered from the operation of gas heat pumps systems is applied to the planning of other plants. The development of a standardized gas heat pump-series is emphasized.

  13. Experimental Evaluation of a Total Heat Recovery Unit with Polymer Membrane Foils

    Fang, Lei; Yuan, Shu; Nie, Jinzhe

    2014-01-01

    A laboratory experimental study was conducted to investigate the energy performance of a total heat recovery unit using a polymer membranes heat exchanger. The study was conducted in twin climate chambers. One of the chambers simulated outdoor climate conditions and the other simulated the climate...... condition indoors. The airflows taken from the two chambers were connected into the total heat recovery unit and exchange heat in a polymer membrane foil heat exchanger installed inside the unit. The temperature and humidity of the air upstream and downstream of the heat exchanger were measured. Based...... on the measured temperature and humidity values, the temperature, humidity, and enthalpy efficiencies of the total heat recovery unit were calculated. The experiment was conducted in different combinations of outdoor climate conditions simulating warm and humid outdoor climates and air-conditioned indoor climate...

  14. Analysis and Choice of Optimal Heating Ventilation Air Conditioning System for a Teaching Unit

    Marina Verdeş

    2007-01-01

    Full Text Available Under the conditions of present society in which providing an optimum interior comfort is confronted with the necessity of the energy consumption reduction, solving this problem depends on the factors which contribute to the achievements of this comfort. Modern buildings -- implicitly teaching unit -- may be equipped with installations which have low energy consumption, respective a heating, cooling and ventilating integrated system with heat pumps system which can assure all the required comfort conditions. This paper underlines the necessity to use the heat pump in heating system for a teaching unit, energetic and economic guides and the possibility to increase them when using cooling and heating mixed. The solution of heat pumps for heating of the teaching unit and the energetic and economic advantages of the system is made in study.

  15. Electric heating of a unit for uranium trioxide production

    Faron, R.; Striff, A.

    1985-01-01

    Ammonium diuranate U 2 O 7 (NH 4 ) 2 containing about 50% of water is dried and transformed by calcination in uranium trioxide UO 3 . Drying and calcination was obtained by air heated by two burners using domestic fuel. In 1984 the plant was transformed for utilization of electric heating improving maintenance cost, decreasing heat losses and by energy saving the payback period on investment is of 2.6 years [fr

  16. Developing maintenance technologies for FBR's heat exchanger units by advanced laser processing

    Nishimura, Akihiko; Shimada, Yukihiro

    2011-01-01

    Laser processing technologies were developed for the purpose of maintenance of FBR's heat exchanger units. Ultrashort laser processing fabricated fiber Bragg grating sensor for seismic monitoring. Fiber laser welding with a newly developed robot system repair cracks on inner wall of heat exchanger tubes. Safety operation of the heat exchanger units will be improved by the advanced laser processing technologies. These technologies are expected to be applied to the maintenance for the next generation FBRs. (author)

  17. Process of recovering shale oil

    1949-01-17

    A process is disclosed for recovering oil from shale rock by means of channels cut in the shale deposit, to which heat is carried for warming the shale mass and which are separated from the fume channels formed in the shale by parts of the shale rock, characterized in that heating elements are put down in the heating channels, which occupy less cross section than these channels, and in the so-formed space between the channel wall and the heating element a filling is placed, which facilitates heat transfer between the heating element and the shale and simultaneously prevents a streaming of the oily product gasified out of the shale from working into the heating element and stopping it.

  18. In vitro studies of the antibacterial activity of Copaifera spp. oleoresins, sodium hypochlorite, and peracetic acid against clinical and environmental isolates recovered from a hemodialysis unit

    Rosimara Gonçalves Leite Vieira

    2018-01-01

    Full Text Available Abstract Background Patients submitted to hemodialysis therapy are more susceptible to infection, especially to infection by Gram-positive bacteria. Various research works have attempted to discover new antimicrobial agents from plant extracts and other natural products. Methods The present study aimed to assess the antibacterial activities of Copaifera duckei, C. reticulata, and C. oblongifolia oleoresins; sodium hypochlorite; and peracetic acid against clinical and environmental isolates recovered from a Hemodialysis Unit. The Minimum Inhibitory Concentration and the Fractionated Inhibitory Concentration Index were determined; the ability of the tested compounds/extracts to inhibit biofilm formation was evaluated by calculating the MICB50 and IC50. Results C. duckei was the most efficient among the assayed Copaifera species, and its oleoresin was more effective than peracetic acid and sodium hypochlorite. Copaifera oleoresins and disinfectants did not act synergistically at any of the tested combinations. Certain of C. duckei oleoresin, peracetic acid, and sodium hypochlorite concentrations inhibited biofilm formation and eradicated 50% of the biofilm population. Conclusion C. duckei oleoresin is a potential candidate for disinfectant formulations. Based on these results and given the high incidence of multi-resistant bacteria in hemodialysis patients, it is imperative that new potential antibacterial agents like C. duckei oleoresin, which is active against Staphylococcus, be included in disinfectant formulations.

  19. In vitro studies of the antibacterial activity of Copaifera spp. oleoresins, sodium hypochlorite, and peracetic acid against clinical and environmental isolates recovered from a hemodialysis unit.

    Vieira, Rosimara Gonçalves Leite; Moraes, Thaís da Silva; Silva, Larissa de Oliveira; Bianchi, Thamires Chiquini; Veneziani, Rodrigo Cassio Sola; Ambrósio, Sérgio Ricardo; Bastos, Jairo Kenupp; Pires, Regina Helena; Martins, Carlos Henrique Gomes

    2018-01-01

    Patients submitted to hemodialysis therapy are more susceptible to infection, especially to infection by Gram-positive bacteria. Various research works have attempted to discover new antimicrobial agents from plant extracts and other natural products. The present study aimed to assess the antibacterial activities of Copaifera duckei , C. reticulata , and C. oblongifolia oleoresins; sodium hypochlorite; and peracetic acid against clinical and environmental isolates recovered from a Hemodialysis Unit. The Minimum Inhibitory Concentration and the Fractionated Inhibitory Concentration Index were determined; the ability of the tested compounds/extracts to inhibit biofilm formation was evaluated by calculating the MICB 50 and IC 50 . C. duckei was the most efficient among the assayed Copaifera species, and its oleoresin was more effective than peracetic acid and sodium hypochlorite. Copaifera oleoresins and disinfectants did not act synergistically at any of the tested combinations. Certain of C. duckei oleoresin, peracetic acid, and sodium hypochlorite concentrations inhibited biofilm formation and eradicated 50% of the biofilm population. C. duckei oleoresin is a potential candidate for disinfectant formulations. Based on these results and given the high incidence of multi-resistant bacteria in hemodialysis patients, it is imperative that new potential antibacterial agents like C. duckei oleoresin, which is active against Staphylococcus , be included in disinfectant formulations.

  20. Isolation of Enterobacter aerogenes carrying blaTEM-1 and blaKPC-3 genes recovered from a hospital Intensive Care Unit.

    Pulcrano, Giovanna; Pignanelli, Salvatore; Vollaro, Adriana; Esposito, Matilde; Iula, Vita Dora; Roscetto, Emanuela; Soriano, Amata Amy; Catania, Maria Rosaria

    2016-06-01

    Enterobacter aerogenes has recently emerged as an important hospital pathogen. In this study, we showed the emergence of E. aerogenes isolates carrying the blaKPC gene in patients colonized by carbapenem-resistant Klebsiella pneumoniae strains. Two multiresistant E. aerogenes isolates were recovered from bronchial aspirates of two patients hospitalized in the Intensive Care Unit at the "Santa Maria della Scaletta" Hospital, Imola. The antimicrobial susceptibility test showed the high resistance to carbapenems and double-disk synergy test confirmed the phenotype of KPC and AmpC production. Other investigation revealed that ESBL and blaKPC genes were carried on the conjugative pKpQIL plasmid. This is a relevant report in Italy that describes a nosocomial infection due to the production of KPC beta-lactamases by an E. aerogenes isolate in patients previously colonized by K. pneumoniae carbapenem-resistant. In conclusion, it's necessary a continuous monitoring of multidrug-resistant strains for the detection of any KPC-producing bacteria that could expand the circulation of carbapenem-resistant pathogens. © 2016 APMIS. Published by John Wiley & Sons Ltd.

  1. Alternative Procedure of Heat Integration Tehnique Election between Two Unit Processes to Improve Energy Saving

    Santi, S. S.; Renanto; Altway, A.

    2018-01-01

    The energy use system in a production process, in this case heat exchangers networks (HENs), is one element that plays a role in the smoothness and sustainability of the industry itself. Optimizing Heat Exchanger Networks (HENs) from process streams can have a major effect on the economic value of an industry as a whole. So the solving of design problems with heat integration becomes an important requirement. In a plant, heat integration can be carried out internally or in combination between process units. However, steps in the determination of suitable heat integration techniques require long calculations and require a long time. In this paper, we propose an alternative step in determining heat integration technique by investigating 6 hypothetical units using Pinch Analysis approach with objective function energy target and total annual cost target. The six hypothetical units consist of units A, B, C, D, E, and F, where each unit has the location of different process streams to the temperature pinch. The result is a potential heat integration (ΔH’) formula that can trim conventional steps from 7 steps to just 3 steps. While the determination of the preferred heat integration technique is to calculate the potential of heat integration (ΔH’) between the hypothetical process units. Completion of calculation using matlab language programming.

  2. Uranium oxide recovering method

    Ota, Kazuaki; Takazawa, Hiroshi; Teramae, Naoki; Onoue, Takeshi.

    1997-01-01

    Nitrates containing uranium nitrate are charged in a molten salt electrolytic vessel, and a heat treatment is applied to prepare molten salts. An anode and a cathode each made of a graphite rod are disposed in the molten salts. AC voltage is applied between the anode and the cathode to conduct electrolysis of the molten salts. Uranium oxides are deposited as a recovered product of uranium, on the surface of the anode. The nitrates containing uranium nitrate are preferably a mixture of one or more nitrates selected from sodium nitrate, potassium nitrate, calcium nitrate and magnesium nitrate with uranium nitrate. The nitrates may be liquid wastes of nitrates. The temperature for the electrolysis of the molten salts is preferably from 150 to 300degC. The voltage for the electrolysis of the molten salts is preferably an AC voltage of from 2 to 6V, more preferably from 4 to 6V. (I.N.)

  3. Cold and heat waves in the United States.

    Barnett, A G; Hajat, S; Gasparrini, A; Rocklöv, J

    2012-01-01

    Extreme cold and heat waves, characterized by a number of cold or hot days in succession, place a strain on people's cardiovascular and respiratory systems. The increase in deaths due to these waves may be greater than that predicted by extreme temperatures alone. We examined cold and heat waves in 99 US cities for 14 years (1987-2000) and investigated how the risk of death depended on the temperature threshold used to define a wave, and a wave's timing, duration and intensity. We defined cold and heat waves using temperatures above and below cold and heat thresholds for two or more days. We tried five cold thresholds using the first to fifth percentiles of temperature, and five heat thresholds using the 95-99 percentiles. The extra wave effects were estimated using a two-stage model to ensure that their effects were estimated after removing the general effects of temperature. The increases in deaths associated with cold waves were generally small and not statistically significant, and there was even evidence of a decreased risk during the coldest waves. Heat waves generally increased the risk of death, particularly for the hottest heat threshold. Cold waves of a colder intensity or longer duration were not more dangerous. Cold waves earlier in the cool season were more dangerous, as were heat waves earlier in the warm season. In general there was no increased risk of death during cold waves above the known increased risk associated with cold temperatures. Cold or heat waves earlier in the cool or warm season may be more dangerous because of a build up in the susceptible pool or a lack of preparedness for extreme temperatures. Copyright © 2011 Elsevier Inc. All rights reserved.

  4. Analysis of Thermal Design of Heating Units with Meteorological Climate Peculiarities

    Seminenko, A. S.; Elistratova, Y. V.; Pererva, M. I.; Moiseev, M. V.

    2018-03-01

    This article is devoted to the analysis of thermal design of heating units, one of the compulsory calculations of heating systems, which ensures their stable and efficient operation. The article analyses the option of a single-pipe heating system with shifted end-capping areas and the overhead supply main; the difference is shown in the calculation results between heat balance equation of the heating unit and calculation of the actual heat flux (heat transfer coefficient) taking into account deviation from the standardized (technical passport) operating conditions. The calculation of the thermal conditions of residential premises is given, the deviation of the internal air temperature is shown taking into account the discrepancy between the calculation results for thermal energy.

  5. Experimental investigations on cylindrical latent heat storage units with sodium acetate trihydrate composites utilizing supercooling

    Dannemand, Mark; Johansen, Jakob Berg; Kong, Weiqiang

    2016-01-01

    unit was tested with 116.3 kg SAT with 0.5% Xanthan rubber as a thickening agent and 4.4% graphite powder. The heat exchange capacity rate during charge was significantly lower for the unit with SAT and Xanthan rubber compared to the unit with SAT and extra water. This was due to less convection...

  6. Experimental investigations on prototype heat storage units utilizing stable supercooling of sodium acetate trihydrate mixtures

    Dannemand, Mark; Dragsted, Janne; Fan, Jianhua

    2016-01-01

    Laboratory tests of two heat storage units based on the principle of stable supercooling of sodium acetate trihydrate (SAT) mixtures were carried out. One unit was filled with 199.5 kg of SAT with 9% extra water to avoid phase separation of the incongruently melting salt hydrate. The other unit...

  7. Simulation of a passive house coupled with a heat pump/organic Rankine cycle reversible unit

    Dumont, Olivier; Carmo, Carolina; Randaxhe, François

    2014-01-01

    This paper presents a dynamic model of a passive house located in Denmark with a large solar absorber, a horizontal ground heat exchanger coupled with a HP/ORC unit. The HP/ORC reversible unit is a module able to work as an Organic Rankine Cycle (ORC) or as a heat pump (HP). There are 3 possible ...... presents a higher global COP because the heat produced on the roof can heat the storage directly.......This paper presents a dynamic model of a passive house located in Denmark with a large solar absorber, a horizontal ground heat exchanger coupled with a HP/ORC unit. The HP/ORC reversible unit is a module able to work as an Organic Rankine Cycle (ORC) or as a heat pump (HP). There are 3 possible...... modes that need to be chosen optimally depending on the weather conditions, the heat demand and the temperature level of the storage. The ORC mode is activated, as long as the heat demand of the house is covered by the storage to produce electricity based upon the heat generated by the solar roof...

  8. An application of the gas-fired chilling and heating units to domestic houses

    Choi, J.H.; Yang, Y.M.; Chae, J.M.; Bang, H.S.; Kwon, O.B.; Yoo, S.I.; Kim, T.H. [R and D Center, Korea Gas Co. (Korea); Lee, T.W.; Kim, T.H.; Kim, B.H.; Hwang, I.J.; Kim, J.Y.; Kim, C.D.; Park, S.J. [Korea Institute of Construction Technology (Korea)

    1999-10-01

    Following researches and considerations were performed in this study for an efficient application of gas-fired chilling and heating units to the residential buildings. (1) Status of domestic cooling and heating for residential building. (2) Various introduction schemes of outdoor unit. (3) Design exclusive area for the gas appliance and installation of it. (4) Ventilation of exhaust gas and heat. (5) Prepare the installation specifications or standards for gas-fired chilling and heating units. (6) Design technique of plumbing for cooling and heating. (7) Evaluation of unit's capacity considering the thermal load of domestic buildings. (8) Cooling and heating system with the unit. (9) Fundamental test for evaluation of applicability. (10) Actual design and construction of experimental house for an application and a demonstration of the developed gas units. (11) Field test for cooling and heating. (12) Evaluation of economic efficiency. (13) Establish a business potential. (14) Establishment of legal and systematic support, energy rate. (15) Troubleshooting in the course of development and application of the new gas appliance. 41 refs., 214 figs., 52 tabs.

  9. Integrating Solar Heating into an Air Handling Unit to Minimize Energy Consumption

    Wilson, Scott A

    2010-01-01

    The purpose of this project was to test a method of integrating solar heating with a small commercial air handling unit (AHU). In order to accomplish this a heat exchanger was placed in the reheat position of the AHU and piped to the solar heating system. This heat exchanger is used to supplement or replace the existing electric reheat. This method was chosen for its ability to utilize solar energy on a more year round basis when compared to a traditional heating system. It allows solar h...

  10. Assessment of the Performance of a Ventilated Window Coupled with a Heat Recovery Unit through the Co-Heating Test

    Ludovico Danza

    2016-01-01

    Full Text Available The aim of the article is to describe the results of an experimental campaign based on the assessment of a heat recovery unit coupled with a dynamic window. Two fully monitored and calibrated outdoor test cells are used, in order to evaluate the energy performance and the related thermal comfort. The former presents a traditional window with double-glazing, aluminum frame and indoor blind and a centrifugal extractor for the air circulation. The latter is equipped with a dynamic window with ventilated and blinded double-glazing provided with a heat exchanger. The connection of the dynamic window and heat recovery unit provides different actions: heat recovery; heat transfer reduction; pre-heating before the exchanger. Different operating configurations allowed the trends of the dynamic system to be assessed in different seasons in terms of energy saving, thermal comfort behavior and energy efficiency. The results showed an overall lower consumption of the innovative system, both in winter and summer, with 20% and 15% energy saving, respectively. In general, the dynamic system provided the best comfort conditions, even if it involves a worse behavior than expected, in the summer season.

  11. Evaluation of heat stress in dry cleaner units:A case study in Qom, Iran

    Javad Malakouti

    2016-04-01

    Full Text Available Background & Aims of the Study: Nowadays, heat stress is one of the most harmful physical agents in workplaces. According to the consequences of heat stress and have no information about it in Qom dry cleaner units, Iran, this study have been designed to evaluate the heat stress among workers of dry cleaner units in Qom province of Iran, in Jul-Aug 2011. Materials & Methods: This cross-sectional study was conducted in 113 units of active dry cleaner units. WBGT (Wet Bulb Globe Temperature index was selected for heat stress evaluation. In order to measure the requisite parameters, WBGT meter made of Casella Company had been used according to ISO 7243. Data had been analyzed according to Occupational Exposure Limits (OELs with SPSS V.16, using analysis of variance, independent T and LSD tests. Results: The average of WBGT index in Qom dry cleaner units of Iran were 28.98±1.64 °C. The average of WBGT index in 66.4% of units was up to 28°C. The average of relative humidity was 42.86%, the average of wet bulb temperature and globe temperature were 25.56°C and 36.72°C, respectively. The findings showed a significant correlation between the average of WBGT index and the standard recommendation level (p<0.0001. In dry cleaner units with less than 10 m2 area, heat stress was higher than other units  significantly (p<0.05. Conclusions: Heat stress in many dry cleaner units in Qom, Iran, was more than recommended OELs. Because of wet bulb and globe temperature in units were high value, the most important measures to heat controls, are technical engineering controls such as  radiation shield, insulation on boilers and modify the cooling systems.

  12. Nuclear safety inspection in treatment process for SG heat exchange tubes deficiency of unit 1, TNPS

    Zhang Chunming; Song Chenxiu; Zhao Pengyu; Hou Wei

    2006-01-01

    This paper describes treatment process for SG heat exchange tubes deficiency of Unit 1, TNPS, nuclear safety inspection of Northern Regional Office during treatment process for deficiency and further inspection after deficiency had been treated. (authors)

  13. 40 CFR 63.6092 - Are duct burners and waste heat recovery units covered by subpart YYYY?

    2010-07-01

    ... Combustion Turbines What This Subpart Covers § 63.6092 Are duct burners and waste heat recovery units covered by subpart YYYY? No, duct burners and waste heat recovery units are considered steam generating units... 40 Protection of Environment 12 2010-07-01 2010-07-01 true Are duct burners and waste heat...

  14. Waste heat recovery for offshore applications

    Pierobon, Leonardo; Kandepu, Rambabu; Haglind, Fredrik

    2012-01-01

    vary in the range 20-30%. There are several technologies available for onshore gas turbines (and low/medium heat sources) to convert the waste heat into electricity. For offshore applications it is not economical and practical to have a steam bottoming cycle to increase the efficiency of electricity...... production, due to low gas turbine outlet temperature, space and weight restrictions and the need for make-up water. A more promising option for use offshore is organic Rankine cycles (ORC). Moreover, several oil and gas platforms are equipped with waste heat recovery units to recover a part of the thermal...... energy in the gas turbine off-gas using heat exchangers, and the recovered thermal energy acts as heat source for some of the heat loads on the platform. The amount of the recovered thermal energy depends on the heat loads and thus the full potential of waste heat recovery units may not be utilized...

  15. Annual cycle solar energy utilization with seasonal storage. Part 7. Examination on design and control of the system partially recovering exhaust heat of heat pump; Kisetsukan chikunetsu ni yoru nenkan cycle taiyo energy riyo system ni kansuru kenkyu. 7. Bubuntekina hainetsu kaishu wo koryoshita baai no sekkei seigyoho no kento

    Tanaka, H; Okumiya, M [Nagoya University, Nagoya (Japan)

    1996-10-27

    The capacity and performance of the existing system that recovers the overall heating and cooling exhaust heat completely into a seasonal storage tank and the system that discharges the exhaust heat slightly to the outside and recovers it partially were compared and investigated. The system uses a central single-duct discharge system as an air-conditioning system. A heat pump and a flat-plate solar collector installed on the roof of a building are used as the heat source. The seasonal storage tank in the ground just under the building is a cylindrical water tank of 5 m deep with the concrete used as body. The upper surface of a storage tank is heat-insulated by a stylo-platform of 200 mm, and the lower side surface by a stylo-platform of 100 mm. Calculation when the difference in temperature used in a seasonal storage tank is set to 35{degree}C and 25{degree}C was performed for the system that has two control methods. The overall exhaust heat recovery system is almost the same in energy performance as the partial exhaust heat recovery system. The partial exhaust heat recovery system is more advantageous on the economic side. 4 refs., 6 figs., 3 tabs.

  16. Thermal Efficiency of Cogeneration Units with Multi-Stage Reheating for Russian Municipal Heating Systems

    Evgeny Lisin

    2016-04-01

    Full Text Available This paper explores the layout of an optimum process for supplying heat to Russian municipal heating systems operating in a market environment. We analyze and compare the standard cogeneration unit design with two-stage reheating of service water coming from controlled extraction locations and layouts that employ three in-line reheaters with heat the supply controlled by a rotary diaphragm and qualitative/quantitative methods (so-called “uncontrolled extraction”. Cogeneration unit designs are benchmarked in terms of their thermal efficiency expressed as a fuel consumption rate. The specific fuel consumption rate on electricity production is viewed as a key parameter of thermal efficiency.

  17. Trial production of ceramic heat storage unit and study on thermal properties and thermal characteristics of the heat storage unit. Mixed salts of Na2CO3, MgCl2 and CaCl2 as heat storage medium

    Shiina, Yasuaki

    1998-12-01

    Heat storage technique of high temperature and high density latent heat can be applied to an accumulator of heat generated by nuclear power plant in the night and to a thermal load absorber. For the practical use of the heat storage technique, it is important to improve heat exchange characteristics between heat storage medium, such as molten salts, and heat transfer fluid because of low thermal conductivity of the molten salts, to improve durability among molten salt and structure materials and to develop the molten salt with stable thermal properties for a long period. Considering the possibility for the improvement of heat exchange characteristics of phase change heat storage system by absorbing molten salt in porous ceramics with high thermal conductivity, high temperature proof and high resistance to corrosion, several samples of the ceramics heat storage unit were made. Basic characteristics of the samples (strength, thermal properties, temperature characteristics during phase change) were measured experimentally and analytically to study the utility and applicability of the samples for the heat storage system. The results show that the heat storage unit should be used in inactive gas condition because water in the air absorbed in the molten salts would yield degeneration of properties and deterioration of strength and that operation temperature should be confined near fusion temperature because some molten salts would be vaporized and mass would be decreased in considerable high temperature. The results also show that when atmospheric temperature changes around the melting temperature, change in ceramic temperature becomes small. This result suggests the possibility that ceramic heat storage unit could be used as thermal load absorber. (J.P.N.)

  18. Large-Scale Combined Heat and Power (CHP) Generation at Loviisa Nuclear Power Plant Unit 3

    Bergroth, N.

    2010-01-01

    Fortum has applied for a Decision in Principle concerning the construction of a new nuclear power plant unit (Loviisa 3) ranging from 2800-4600 MWth at its site located at the southern coast of Finland. An attractive alternative investigated is a co-generation plant designed for large-scale district heat generation for the Helsinki metropolitan area that is located approximately 75 km west of the site. The starting point is that the district heat generation capacity of 3 unit would be around 1 000 MWth.The possibility of generating district heat for the metropolitan area by Loviisa's two existing nuclear power plant units was investigated back in the 1980s, but it proved unpractical at the time. With the growing concern of the climate change and the subsequent requirements on heat and power generation, the idea is much more attractive today, when recognising its potential to decrease Finland's carbon dioxide emissions significantly. Currently the district heat generation in metropolitan area is based on coal and natural gas, producing some five to seven million tonnes of carbon dioxide emissions annually. Large-scale combined heat and power (CHP) generation at the 3 unit could cut this figure by up to four million tonnes. This would decrease carbon dioxide emissions by as much as six percent. In addition, large-scale CHP generation would increase the overall efficiency of the new unit significantly and hence, reduce the environmental impact on the local marine environment by cutting heat discharges into the Gulf of Nuclear energy has been used for district heating in several countries both in dedicated nuclear heating plants and in CHP generation plants. However, the heat generation capacity is usually rather limited, maximum being around 250 MWth per unit. Set against this, the 3 CHP concept is much more ambitious, not only because of the much larger heat generation output envisaged, but also because the district heating water would have to be transported over a

  19. Thermal performance analysis of a phase change thermal storage unit for space heating

    Halawa, E.; Saman, W. [Institute for Sustainable Systems and Technologies School of Advanced Manufacturing and Mechanical Engineering, University of South Australia, Mawson Lakes SA 5095 (Australia)

    2011-01-15

    This paper presents the results of a comprehensive numerical study on the thermal performance of an air based phase change thermal storage unit (TSU) for space heating. The unit is designed for integration into space heating and cooling systems. The unit consists of a number of one dimensional phase change material (PCM) slabs contained in a rectangular duct where air passes between the slabs. The numerical analysis was based on an experimentally validated model. A parametric study has been carried out including the study on the effects of charge and discharge temperature differences, air mass flow rate, slab thicknesses, air gaps and slab dimensions on the air outlet temperatures and heat transfer rates of the thermal storage unit. The paper introduces and discusses quantities called charge and discharge temperature differences which play an important role in the melting and freezing processes. (author)

  20. Heat-transfer, inside of the ground heat-transfer units, from liquid, additionally cooling the oil-immersed transformer

    Madyshev Ilnur

    2017-01-01

    Full Text Available A device for cooling the oil-immersed transformer by means of thermoelectric transducers has been developed. Their operating principle is based on the fact that at night at minimum ambient temperature, the cold is accumulated inside of a vessel due to formation of water ice layer on the developed surfaces of thermoelectric transducers` ribs. Melting of this layer is used in the hottest time of a day for additional cooling of transformer oil in the cooling system of the transformer. Pre-cooling of the circulating water takes place in vertical ground heat-transfer units (VGHT units, mounted into ground drilled boreholes. Certain estimate calculations of the heat-transfer process have been carried out.

  1. Field tests for the comparative evaluation of heat and enthalpy exchangers in compact ventilation units; Feldvergleich von Waerme- und Enthalpieuebertragern in Kompakt-Lueftungsgeraeten - Schlussbericht

    Frei, B.

    2007-07-01

    In an efficiency review on low energy buildings promoted by the Swiss Federal Office of Energy, low air humidity has been measured during thousands of annual hours. Modern compact ventilation units are being increasingly offered with transmission of heat and moisture. One possibility to raise the air humidity level is an enthalpy exchanger with steam-permeable membranes. With an enthalpy exchanger you can not only recover heat but also a good part of the humidity of the return air. In a comparative field study alternate applications with enthalpy or heat exchangers have been analysed at four different locations. Also calculations have been made to estimate how a rotating heat exchanger with ion-exchange resin would have performed. The comparative field study has shown that the enthalpy exchanger is able to raise the humidity level. Conditions for this are internal humidity loads, balanced air volume rates which correspond to occupancy as well as low leakages of the ventilation unit. Over-moistening due to the system with enthalpy exchanger was not found. The measurements have been affected by a sequence of winter months which have been partially warmer than usual. Otherwise the difference between enthalpy and heat exchangers would have been more significant. (author)

  2. Do diurnal patterns of branch carbon uptake and transpiration recover after heat waves? Results from a Mediterranean-type ecosystem experiencing seasonal and exceptional drought

    Pivovaroff, A. L.; Pesqueira, A.; Sun, W.; Seibt, U.

    2016-12-01

    Mediterranean-type ecosystems are biodiversity hotspots, but increasing temperature and changes in precipitation will have significant impacts on vegetation, as evidenced by the current die-back of many woody species in southern California, USA, due to exceptional drought conditions. We installed flow-through chambers on four native woody plant species at Stunt Ranch, a University of California Natural Reserve System site, in order to continuously monitor fluxes of carbon and water at the branch-scale from the growing season through the annual seasonal drought period. Study species included Heteromeles arbutifolia, Malosma laurina, Salvia leucophylla, and Quercus agrifolia. Here we present the results of diurnal flux patterns before, during, and after two extreme heat waves events, when daily maximum temperatures doubled. Under typical summer conditions, which include hot, sunny days, study species exhibited two peaks in carbon assimilation during a diurnal cycle: a peak in the morning and a smaller, secondary peak in the afternoon, separated by a midday depression. During heat wave events, which generally lasted 3 days, species exhibited a small morning peak and no afternoon peak at all. All study species returned to their pre-heat wave diurnal flux patterns, which included the second afternoon peak, when weather conditions returned to normal. Since soil moisture was not affected by the short-term heat wave events, we conclude that the pronounced changes in diurnal patterns, including disappearance of the secondary afternoon peak, are the result of stomatal regulation in response to atmospheric water demand rather than root responses to soil moisture deficits. Our results demonstrate that carbon uptake of native species may be impacted under ongoing climate change when increased temperatures and drought conditions may be sustained.

  3. Calculation method for the seasonal performance of heat pump compact units and validation. Final report

    Wemhoener, C.; Dott, R.; Afjei, Th. [University of Applied Sciences Northwestern Switzerland, Institute of Energy in Buildings, Muttenz (Switzerland); Huber, H.; Helfenfinger, D.; Keller, P.; Furter, R. [University of Applied Sciences Lucerne (HTA), Test center HLKS, Horw (Switzerland)

    2007-02-15

    This comprehensive final report for the Swiss Federal Office of Energy (SFOE) takes a look at compact heat pump units that have been developed for the heating of low energy consumption houses built to MINERGIE or MINERGIE-P standards. These units, which combine the functions of space heating, domestic hot water preparation and ventilation in one unit are described. A testing procedure developed at the University of Applied Science in Lucerne, Switzerland, using a test rig for the measurement of the seasonal performance factor (SPF) is described. A calculation method based on temperature classes for the calculation of the SPF of combined heat pump systems for space heating and domestic hot water preparation that was developed by the Institute of Energy in Buildings at the University of Applied Sciences Northwestern Switzerland is examined. Two pilot plants allowing detailed field monitoring of two compact units are described. One pilot plant installed in a single-family house built to MINERGIE standard in Gelterkinden, Switzerland, provided data on a compact unit. These results of measurements made on this and a further installation in a MINERGIE-P ultra-low energy consumption house in Zeiningen, Switzerland, are presented and discussed. Calculation methods, including exergy considerations are reviewed and their validation is discussed.

  4. Cooperation of Horizontal Ground Heat Exchanger with the Ventilation Unit During Summer - Case Study

    Romańska-Zapała, Anna; Furtak, Marcin; Dechnik, Mirosław

    2017-10-01

    Renewable energy sources are used in the modern energy-efficient buildings to improve their energy balance. One of them is used in the mechanical ventilation system ground air heat exchanger (earth-air heat exchanger - EAHX). This solution, right after heat recovery from exhaust air (recuperation), allows the reduction in the energy needed to obtain the desired temperature of supply air. The article presents the results of "in situ" measurements of pipe ground air heat exchanger cooperating with the air handling unit, supporting cooling the building in the summer season, in Polish climatic conditions. The laboratory consists of a ventilation unit intake - exhaust with rotor for which the source of fresh air is the air intake wall and two air intakes field cooperating with the tube with ground air heat exchangers. Selection of the source of fresh air is performed using sprocket with actuators. This system is part of the ventilation system of the Malopolska Laboratory of Energy-Efficient Building (MLBE) building of Cracow University of Technology. The measuring system are, among others, the sensors of parameters of air inlets and outlets of the heat exchanger channels EAHX and weather station that senses the local weather conditions. The measurement data are recorded and archived by the integrated process control system in the building of MLBE. During the study measurements of operating parameters of the ventilation unit cooperating with the selected source of fresh air were performed. Two cases of operation of the system: using EAHX heat exchanger and without it, were analyzed. Potentially the use of ground air heat exchanger in the mechanical ventilation system can reduce the energy demand for heating or cooling rooms by the pre-adjustment of the supply air temperature. Considering the results can be concluded that the continuous use of these exchangers is not optimal. This relationship is appropriate not only on an annual basis for the transitional periods (spring

  5. Calculation method for the seasonal performance of heat pump compact units and validation. Appendix

    Wemhoener, C.; Dott, R.; Afjei, Th. [University of Applied Sciences Northwestern Switzerland, Institute of Energy in Buildings, Muttenz (Switzerland); Huber, H.; Helfenfinger, D.; Keller, P.; Furter, R. [University of Applied Sciences Lucerne (HTA), Test center HLKS, Horw (Switzerland)

    2007-02-15

    This appendix to a comprehensive final report for the Swiss Federal Office of Energy (SFOE) presents the results of tests made on compact heat pump units that have been developed for the heating of low energy consumption houses built to MINERGIE or MINERGIE-P standards. The tests on these units, which combine the functions of space heating, domestic hot water preparation and ventilation in one unit are presented and discussed. Test conditions are described; these cover ventilation, acoustic, hygiene and safety aspects. Detailed results from the two test objects - buildings built to MINERGIE and MINERGIE-P low energy consumption standards - are presented and discussed. The calculation methods used are examined and discussed.

  6. SOME METHODS FOR SAVING HEAT ENERGY WHILE MANUFACTURING VERTICAL INSULATING GLASS UNITS

    S. A. Shybeka

    2018-01-01

    Full Text Available The paper proposes and considers two constructive methods for saving heat energy while manufacturing vertical insulating glass units with various gas filling of inter-glass space. The first method presupposes manufacturing of insulating glass units having specific thickness which is calculated in accordance with specific features of convective heat exchange in the closed loop circuit. Value of the heat-exchange coefficient depends on gas properties which is filling a chamber capacity (coefficients of thermal conductivity, volumetric expansion, kinematic viscosity, thermometric conducivity, temperature difference on the boundary of interlayer and its thickness. It has been shown that while increasing thickness of gas layer convective heat exchange coefficient is initially decreasing up to specific value and then after insignificant increase it practically remains constant. In this connection optimum thicknesses of filled inter-layers for widely-spread gas in production (dry air, argon, krypton, xenon and for carbon dioxide have determined in the paper. Manufacturing of insulating glass units with large thickness of gas chamber practically does not lead to an increase in resistance to heat transfer but it will increase gas consumption rate. The second industrial economic method is interrelated with application of carbon dioxide СО2 as a filler of inter-glass space which has some advantages in comparison with other gases (small cost due to abundance, nontoxicity, transparency for visual light and absorption of heat rays. Calculations have shown that application of carbon dioxide will make it possible to increase resistance to heat transfer of one-chamber glass unit by 0.05 m²×K/W (with emissivity factor of internal glass – 0.837 or by 0.16 m²×K/W (with emission factor – 0.1 in comparison with the glass unit where a chamber is filled with dry air.

  7. Performance analysis of phase-change material storage unit for both heating and cooling of buildings

    Waqas, Adeel; Ali, Majid; Ud Din, Zia

    2017-04-01

    Utilisation of solar energy and the night ambient (cool) temperatures are the passive ways of heating and cooling of buildings. Intermittent and time-dependent nature of these sources makes thermal energy storage vital for efficient and continuous operation of these heating and cooling techniques. Latent heat thermal energy storage by phase-change materials (PCMs) is preferred over other storage techniques due to its high-energy storage density and isothermal storage process. The current study was aimed to evaluate the performance of the air-based PCM storage unit utilising solar energy and cool ambient night temperatures for comfort heating and cooling of a building in dry-cold and dry-hot climates. The performance of the studied PCM storage unit was maximised when the melting point of the PCM was ∼29°C in summer and 21°C during winter season. The appropriate melting point was ∼27.5°C for all-the-year-round performance. At lower melting points than 27.5°C, declination in the cooling capacity of the storage unit was more profound as compared to the improvement in the heating capacity. Also, it was concluded that the melting point of the PCM that provided maximum cooling during summer season could be used for winter heating also but not vice versa.

  8. Energy Savings and Breakeven Costs for Residential Heat Pump Water Heaters in the United States

    Maguire, Jeff [National Renewable Energy Lab. (NREL), Golden, CO (United States); Burch, Jay [National Renewable Energy Lab. (NREL), Golden, CO (United States); Merrigan, Tim [National Renewable Energy Lab. (NREL), Golden, CO (United States); Ong, Sean [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2013-07-01

    Heat pump water heaters (HPWHs) have recently re-emerged in the U.S. residential water heating market and have the potential to provide homeowners with significant energy savings. However, there are questions as to the actual performance and energy savings potential of these units, in particular in regards to the heat pump's performance in unconditioned space and the impact of the heat pump on space heating and cooling loads when it is located in conditioned space. To help answer these questions, NREL performed simulations of a HPWH in both conditioned and unconditioned space at over 900 locations across the continental United States and Hawaii. Simulations included a Building America benchmark home so that any interaction between the HPWH and the home's HVAC equipment could be captured. Comparisons were performed to typical gas and electric water heaters to determine the energy savings potential and cost effectiveness of a HPWH relative to these technologies. HPWHs were found to have a significant source energy savings potential when replacing typical electric water heaters, but only saved source energy relative to gas water heater in the most favorable installation locations in the southern United States. When replacing an electric water heater, the HPWH is likely to break even in California, the southern United States, and parts of the northeast in most situations. However, the HPWH will only break even when replacing a gas water heater in a few southern states.

  9. Centrifugal Compressor Unit-based Heat Energy Recovery at Compressor Stations

    V. S. Shadrin

    2016-01-01

    Full Text Available About 95% of the electricity consumed by air compressor stations around the world, is transformed into thermal energy, which is making its considerable contribution to global warming. The present article dwells on the re-use (recovery of energy expended for air compression.The article presents the energy analysis of the process of compressing air from the point of view of compressor drive energy conversion into heat energy. The temperature level of excess heat energy has been estimated in terms of a potential to find the ways of recovery of generated heat. It is shown that the temperature level formed by thermal energy depends on the degree of air compression and the number of stages of the compressor.Analysis of technical characteristics of modern equipment from leading manufacturers, as well as projects of the latest air compressor stations have shown that there are two directions for the recovery of heat energy arising from the air compression: Resolving technological problems of compressor units. The use of the excess heat generation to meet the technology objectives of the enterprise. This article examines the schematic diagrams of compressor units to implement the idea of heat recovery compression to solve technological problems: Heating of the air in the suction line during operation of the compressor station in winter conditions. Using compression heat to regenerate the adsorbent in the dryer of compressed air.The article gives an equity assessment of considered solutions in the total amount of heat energy of compressor station. Presented in the present work, the analysis aims to outline the main vectors of technological solutions that reduce negative impacts of heat generation of compressor stations on the environment and creating the potential for reuse of energy, i.e. its recovery.

  10. Study of the thermal behavior of a latent heat cold storage unit operating under frosting conditions

    Simard, A.P.; Lacroix, M.

    2003-01-01

    A study is performed of the thermal behavior of a latent heat cold storage unit operating under frosting conditions. This unit is employed to maintain the temperature inside the refrigerated compartment of a truck below 265 K. The system consists of parallel plates filled with a phase change material (PCM) that absorbs heat from the flow of warm moist air. A mathematical model for the system is first presented and, next, validated with numerical and experimental data. It is then exploited to assess the effects of design parameters and operating conditions on the performance of the system. The recommended thickness and distance separating the PCM plates are found to be 50x10 -3 and 30x10 -3 m, respectively. The results indicate that the performance of the unit is enhanced by turbulent air flow in spite of the increased pressure loss and accentuated frost growth. The unit also performs well even when the surrounding relative humidity is 100%

  11. Accelerating the energy policy turnaround with combined heat and power units; Mit Blockheizkraftwerken die Energiewende rund machen

    Lange, Joerg; Geiler, Nikolaus [Klimabuendnis Freiburg, Freiburg im Breisgau (Germany)

    2013-03-15

    No other type of decentralized power plants transforms natural gas to electric power so efficiently as a combined heat and power unit. In the long term, the climate-friendly effect using renewable hydrogen or renewably generated 'natural gas' even could be increased. Thus, combined heat and power units are ideal to achieve the national climate change objectives. Despite their advantages, the implementation of combined heat and power units advances only sluggishly.

  12. Study on constraints for heat removal duties of the main fractionator in delayed coking units

    Lei, Yang; Zhang, Bingjian; Qi, Xin; Chen, Qinglin; Hui, Chi-Wai

    2014-01-01

    A novel method is presented in this paper to quantitatively define the heat removal of the main fractionator in delayed coking units on the basis of a fractionating precision diagram (Houghland diagram) and column grand composite curve (CGCC). By referring to the CGCC method, several envelopes are illustrated at draw trays including the top pumparound draw, diesel draw, intermediate pumparound draw and gas oil draw, the energy and material balances are then calculated. Assuming practical near-minimum thermodynamic condition (PNMTC), the minimum liquid reflux flow is zero in the envelope for pumparound trays without product draw and the minimum liquid reflux flow is defined by Houghland diagram for pumparound trays with product draw. The PNMTC-CGCC is constructed by calculating the enthalpy-flow deficit to quantitatively define the heat removal constraints in each envelope. Meanwhile, the corresponding practical heat removal curve is constructed. A case study shows that the high temperature heat removal ratio within the main fractionator increased by 8%. The proposed method offers heat removal inequality constraints for the model to optimize the heat integration between the main fractionator and the heat exchanger network. - Highlights: • A novel method defines the heat removal constraints of the main fractionator. • Fractionating precision diagram and column grand composite curve are combined. • The results are the inequality constraints in a simultaneous optimization model

  13. He II Heat Exchanger Test Unit for the LHC Inner Triplet

    Blanco-Viñuela, E; Huang, Y; Nicol, T H; Peterson, T; Van Weelderen, R

    2002-01-01

    The Inner Triplet Heat Exchanger Test Unit (IT-HXTU) is a 30-m long thermal model designed at Fermilab, built in US industry, fully automated and tested at CERN as part of the US LHC program to develop the LHC Interaction Region quadrupole system. The cooling scheme of the IT-HXTU is based on heat exchange between stagnant pressurized He II in the magnet cold mass and saturated He II (two-phase) flowing in a heat exchanger located outside of and parallel to the cold mass. The purposes of this test are, among others, to validate the proposed cooling scheme and to define an optimal control strategy to be implemented in the future LHC accelerator. This paper discusses the results for the heat exchanger test runs and emphasizes the thermal and hydraulic behavior of He II for the inner triplet cooling scheme.

  14. Early emergence of anthropogenically forced heat waves in the western United States and Great Lakes

    Lopez, Hosmay; West, Robert; Dong, Shenfu; Goni, Gustavo; Kirtman, Ben; Lee, Sang-Ki; Atlas, Robert

    2018-05-01

    Climate projections for the twenty-first century suggest an increase in the occurrence of heat waves. However, the time at which externally forced signals of anthropogenic climate change (ACC) emerge against background natural variability (time of emergence (ToE)) has been challenging to quantify, which makes future heat-wave projections uncertain. Here we combine observations and model simulations under present and future forcing to assess how internal variability and ACC modulate US heat waves. We show that ACC dominates heat-wave occurrence over the western United States and Great Lakes regions, with ToE that occurred as early as the 2020s and 2030s, respectively. In contrast, internal variability governs heat waves in the northern and southern Great Plains, where ToE occurs in the 2050s and 2070s; this later ToE is believed to be a result of a projected increase in circulation variability, namely the Great Plain low-level jet. Thus, greater mitigation and adaptation efforts are needed in the Great Lakes and western United States regions.

  15. Energy Savings and Breakeven Cost for Residential Heat Pump Water Heaters in the United States

    Maguire, J.; Burch, J.; Merrigan, T.; Ong, S.

    2013-07-01

    Heat pump water heaters (HPWHs) have recently reemerged in the U.S. residential water heating market and have the potential to provide homeowners with significant energy savings. However, there are questions as to the actual performance and energy savings potential of these units, in particular in regards to the heat pump's performance in unconditioned space and the impact of the heat pump on space heating and cooling loads when it is located in conditioned space. To help answer these questions, simulations were performed of a HPWH in both conditioned and unconditioned space at over 900 locations across the continental United States and Hawaii. Simulations included a Building America benchmark home so that any interaction between the HPWH and the home's HVAC equipment could be captured. Comparisons were performed to typical gas and electric water heaters to determine the energy savings potential and cost effectiveness of a HPWH relative to these technologies. HPWHs were found to have a significant source energy savings potential when replacing typical electric water heaters, but only saved source energy relative to gas water heater in the most favorable installation locations in the southern US. When replacing an electric water heater, the HPWH is likely to break even in California, the southern US, and parts of the northeast in most situations. However, the HPWH will only break even when replacing a gas water heater in a few southern states.

  16. Comparison of Advanced Residential Water Heating Technologies in the United States

    Maguire, Jeff [National Renewable Energy Lab. (NREL), Golden, CO (United States); Fang, Xia [National Renewable Energy Lab. (NREL), Golden, CO (United States); Wilson, Eric [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2013-05-01

    In this study, gas storage, gas tankless, condensing, electric storage, heat pump, and solar water heaters were simulated in several different climates across the United States, installed in both conditioned and unconditioned space and subjected to several different draw profiles. While many pre-existing models were used, new models of condensing and heat pump water heaters were created specifically for this work. In each case modeled, the whole house was simulated along with the water heater to capture any interactions between the water heater and the space conditioning equipment.

  17. A heated vapor cell unit for dichroic atomic vapor laser lock in atomic rubidium.

    McCarron, Daniel J; Hughes, Ifan G; Tierney, Patrick; Cornish, Simon L

    2007-09-01

    The design and performance of a compact heated vapor cell unit for realizing a dichroic atomic vapor laser lock (DAVLL) for the D(2) transitions in atomic rubidium is described. A 5 cm long vapor cell is placed in a double-solenoid arrangement to produce the required magnetic field; the heat from the solenoid is used to increase the vapor pressure and correspondingly the DAVLL signal. We have characterized experimentally the dependence of important features of the DAVLL signal on magnetic field and cell temperature. For the weaker transitions both the amplitude and gradient of the signal are increased by an order of magnitude.

  18. A heated vapor cell unit for dichroic atomic vapor laser lock in atomic rubidium

    McCarron, Daniel J.; Hughes, Ifan G.; Tierney, Patrick; Cornish, Simon L.

    2007-01-01

    The design and performance of a compact heated vapor cell unit for realizing a dichroic atomic vapor laser lock (DAVLL) for the D 2 transitions in atomic rubidium is described. A 5 cm long vapor cell is placed in a double-solenoid arrangement to produce the required magnetic field; the heat from the solenoid is used to increase the vapor pressure and correspondingly the DAVLL signal. We have characterized experimentally the dependence of important features of the DAVLL signal on magnetic field and cell temperature. For the weaker transitions both the amplitude and gradient of the signal are increased by an order of magnitude

  19. HEAT STORAGE SYSTEM WITH PHASE CHANGE MATERIALS IN COGENERATION UNITS: STUDY OF PRELIMINARY MODEL

    Claudio Caprara

    2008-12-01

    Full Text Available The continuous increase in the mechanization of farm activities, the rise in fuel prices and the environmental aspects concerning gas emissions are the main driving forces behind efforts toward more effective use of renewable energy sources and cogeneration systems even in agricultural and cattle farms. Nevertheless these systems are still not very suitable for this purpose because of their little flexibility in following the changing energy demand as opposed to the extremely various farm load curves, both in daytime and during the year. In heat recovery systems, the available thermal energy supply is always linked to power production, thus it does not usually coincide in time with the heat demand. Hence some form of thermal energy storage (TES is necessary in order to reach the most effective utilization of the energy source. This study deals with the modelling of a packed bed latent heat TES unit, integrating a cogeneration system made up of a reciprocating engine. The TES unit contains phase change materials (PCMs filled in spherical capsules, which are packed in an insulated cylindrical storage tank. Water is used as heat transfer fluid (HTF to transfer heat from the tank to the final uses, and exhausts from the engine are used as thermal source. PCMs are considered especially for their large heat storage capacity and their isothermal behaviour during the phase change processes. Despite their high energy storage density, most of them have an unacceptably low thermal conductivity, hence PCMs encapsulation technique is adopted in order to improve heat transfer. The special modular configuration of heat exchange tubes and the possibility of changing water flow through them allow to obtain the right amount of thermal energy from the tank, according to the hourly demand of the day. The model permits to choose the electrical load of the engine, the dimensions of the tank and the spheres, thickness and diameter of heat exchanger and the nature of

  20. Method for heating of the primary circuit of WWER electric power units at cold start-up

    Ivanov, I.N.; Dimitrov, B.D.; Korkinova, M.I.

    1982-01-01

    The method increases the heating rate and shorten the start-up time of the electric power units. It comprises a primary stopping of the reactor core heating and provides a forced circulation of the heat-carrier through the circulation cycles of the primary circuit. The thermal energy is supplied in one or several steam generators in the secondary circuit of an NPP operating unit. 1 cl., 3 figs

  1. Heat recovery from a cement plant with a Marnoch Heat Engine

    Saneipoor, P.; Naterer, G.F.; Dincer, I.

    2011-01-01

    This paper examines the performance of a new Marnoch Heat Engine (MHE) that recovers waste heat from within a typical cement plant. Two MHE units with compressed air as the working fluid are installed to recover the waste heat. The first unit on the main stack has four pairs of shell and tube heat exchangers. The second heat recovery unit is installed on a clinker quenching system. This unit operates with three pairs of shell and tube heat exchangers. The recovered heat is converted to electricity through the MHE system and used internally within the cement plant. A predictive model and results are presented and discussed. The results show the promising performance of the MHE's capabilities for efficient generation of electricity from waste heat sources in a cement plant. The new heat recovery system increases the efficiency of the cement plant and lowers the CO 2 emissions from the clinker production process. Moreover, it reduces the amount of waste heat to the environment and lowers the temperature of the exhaust gases. - Highlights: → This paper examines the thermodynamic performance of a new Marnoch Heat Engine (MHE) that recovers waste heat to produce electricity and improve the operating efficiency of a typical cement plant. → The first unit of the MHE on the main stack has four pairs of shell and tube heat exchangers and the second heat recovery unit is installed on a clinker quenching system. → Both predicted and experimental results demonstrate the promising performance of the MHE's capabilities for efficient generation of electricity from waste heat sources in a cement plant.

  2. Simulation and design of distillation units for treatment of sulfite pulping condensates to recover methanol and furfural. Part II. Applicability of multiple-effect distillation using live steam

    Aly, G.; Zacchi, G.

    1979-06-01

    A distillation unit has been designed for a capacity of 73 t/h of condensate and for at least 90% recovery of the contaminating organics. This unit consists of three columns: a primary stripper to remove volatile organics and two upgrading columns to purify the methanol and furfural byproducts. Three different energy-saving alternatives for satisfying the energy requirements have been studied: utilisation of secondary steam from the evaporation plant, and application of the principle of multi-effect distillation in one-stripper and in two-stripper configurations. Investment cost needed in all alternatives amounts to 5.5 to 6.0 MCr (millions of Swedish Crowns) while operating cost varies between 0.8 to 3.1 MCr. The first design alternative has a payoff period of 2.3 years while the two multi-effect distillation alternatives have a payoff period of about 3 years.

  3. PROCESS OF RECOVERING URANIUM

    Carter, J.M.; Larson, C.E.

    1958-10-01

    A process is presented for recovering uranium values from calutron deposits. The process consists in treating such deposits to produce an oxidlzed acidic solution containing uranium together with the following imparities: Cu, Fe, Cr, Ni, Mn, Zn. The uranium is recovered from such an impurity-bearing solution by adjusting the pH of the solution to the range 1.5 to 3.0 and then treating the solution with hydrogen peroxide. This results in the precipitation of uranium peroxide which is substantially free of the metal impurities in the solution. The peroxide precipitate is then separated from the solution, washed, and calcined to produce uranium trioxide.

  4. Evaluation of the performance of combined cooling, heating, and power systems with dual power generation units

    Knizley, Alta A.; Mago, Pedro J.; Smith, Amanda D.

    2014-01-01

    The benefits of using a combined cooling, heating, and power system with dual power generation units (D-CCHP) is examined in nine different U.S. locations. One power generation unit (PGU) is operated at base load while the other is operated following the electric load. The waste heat from both PGUs is used for heating and for cooling via an absorption chiller. The D-CCHP configuration is studied for a restaurant benchmark building, and its performance is quantified in terms of operational cost, primary energy consumption (PEC), and carbon dioxide emissions (CDE). Cost spark spread, PEC spark spread, and CDE spark spread are examined as performance indicators for the D-CCHP system. D-CCHP system performance correlates well with spark spreads, with higher spark spreads signifying greater savings through implementation of a D-CCHP system. A new parameter, thermal difference, is introduced to investigate the relative performance of a D-CCHP system compared to a dual PGU combined heat and power system (D-CHP). Thermal difference, together with spark spread, can explain the variation in savings of a D-CCHP system over a D-CHP system for each location. The effect of carbon credits on operational cost savings with respect to the reference case is shown for selected locations. - Highlights: • We investigate benefits from using combined cooling, heating, and power systems. • A dual power generation unit configuration is considered for CCHP and CHP. • Spark spreads for cost, energy, and emissions correlate with potential savings. • Thermal difference parameter helps to explain variations in potential savings. • Carbon credits may increase cost savings where emissions savings are possible

  5. A Direct Heat Exchanger Unit used for Domestic Hot Water Supply in a Single-family House Supplied by Low Energy District Heating

    Brand, Marek; Thorsen, Jan Eric; Svendsen, Svend

    2010-01-01

    The increasing number of new and renovated buildings with reduced heating requirements will soon make traditional District Heating (DH) systems uneconomic. To keep DH competitive in the future, the heat loss in DH networks needs to be reduced. One option is to reduce the supply temperature of DH...... as much as possible. This requires a review of the behaviour of the whole domestic hot water (DHW) supply system with focus on the user comfort and overall costs. This paper describes some practical approaches to the implementation of this Low Energy District Heating (LEDH) concept. It reports...... on the testing of the dynamic behaviour of an Instantaneous Heat Exchanger Unit(IHEU) designed for DHW heating and space heating in detached family houses supplied by LEDH ensuring an entry-to-substation temperature of 51 °C. We measured the time it takes for the IHEU to produce DHW with a temperature of 42 °C...

  6. ANALYSIS OF THE INFLUENCE OF PARAMETERS OF CONTROL OF HEATING POWER GENERATING UNITS ON FUEL CONSUMPTION

    Shchinnikov P.A.

    2011-04-01

    Full Text Available It is presented analysis of the influence of parameters of state of the process of control on the increase of the fuel consumption of heat power generating units. There are presented results of calculations of the increase of the fuel consumption at the deviation of the working steam temperature and pressure from rated values. Result of calculus is compared with the experiment.

  7. Sizing Combined Heat and Power Units and Domestic Building Energy Cost Optimisation

    Dongmin Yu; Yuanzhu Meng; Gangui Yan; Gang Mu; Dezhi Li; Simon Le Blond

    2017-01-01

    Many combined heat and power (CHP) units have been installed in domestic buildings to increase energy efficiency and reduce energy costs. However, inappropriate sizing of a CHP may actually increase energy costs and reduce energy efficiency. Moreover, the high manufacturing cost of batteries makes batteries less affordable. Therefore, this paper will attempt to size the capacity of CHP and optimise daily energy costs for a domestic building with only CHP installed. In this paper, electricity ...

  8. Thermal-economic optimization of an air-cooled heat exchanger unit

    Alinia Kashani, Amir Hesam; Maddahi, Alireza; Hajabdollahi, Hassan

    2013-01-01

    Thermodynamic modeling and optimal design of an air-cooled heat exchanger (ACHE) unit are developed in this study. For this purpose, ε–NTU method and mathematical relations are applied to estimate the fluids outlet temperatures and pressure drops in tube and air sides. The main goal of this study is minimizing of two conflicting objective functions namely the temperature approach and the minimum total annual cost, simultaneously. For this purpose, fast and elitist non-dominated sorting genetic-algorithm (NSGA-II) is applied to minimize the objective functions by considering ten design parameters. In addition, a set of typical constraints, governing on the ACHE unit design, is subjected to obtain more practical optimum design points. Furthermore, sensitivity analysis of change in the objective functions, when the optimum design parameters vary, is conducted and the degree of each parameter on conflicting objective functions has been investigated. Finally, a selection procedure of the best optimum point is introduced and final optimum design point is determined. -- Highlights: ► Multi-objective optimization of air-cooled heat exchanger. ► Considering ten new design parameters in this type of heat exchanger. ► A detailed cost function is used to estimate the heat exchanger investment cost. ► Presenting a mathematical relation for optimum total cost vs. temperature approach. ► The sensitivity analysis of parameters in the optimum situation

  9. Exertional heat stroke management strategies in United States high school football.

    Kerr, Zachary Y; Marshall, Stephen W; Comstock, R Dawn; Casa, Douglas J

    2014-01-01

    The 5-year period of 2005-2009 saw more exertional heat stroke-related deaths in organized sports than any other 5-year period in the past 35 years. The risk of exertional heat stroke appears highest in football, particularly during the preseason. To estimate the incidence of exertional heat stroke events and assess the utilization of exertional heat stroke management strategies during the 2011 preseason in United States high school football programs. Cross-sectional study; Level of evidence, 3. A self-administered online questionnaire addressing the incidence of exertional heat stroke events and utilization of exertional heat stroke management strategies (eg, removing athlete's football equipment, calling Emergency Medical Services [EMS]) was completed in May to June 2012 by 1142 (18.0%) athletic trainers providing care to high school football athletes during the 2011 preseason. Among all respondents, 20.3% reported treating at least 1 exertional heat stroke event. An average of 0.50 ± 1.37 preseason exertional heat stroke events were treated per program. Athletic trainers responding to exertional heat stroke reported using an average of 6.6 ± 1.8 management strategies. The most common management strategies were low-level therapeutic interventions such as removing the athlete's football equipment (98.2%) and clothing (77.8%) and moving the athlete to a shaded area (91.6%). Few athletic trainers reported active management strategies such as calling EMS (29.3%) or using a rectal thermometer to check core body temperature (0.9%). Athletic trainers in states with mandated preseason heat acclimatization guidelines reported a higher utilization of management strategies such as cooling the athlete through air conditioning (90.1% vs 65.0%, respectively; P football programs. The standard of care is (and should be) to treat proactively; therefore, treatment is not a perfect proxy for incidence. Nevertheless, there is an urgent need for improved education and awareness of

  10. Emission factors of modern wood-pellet heating units under typical heating conditions - Final report; Emissionsfaktoren moderner Pelletkessel unter typischen Heizbedingungen - Schlussbericht

    Good, J.; Nussbaumer, T.

    2009-12-15

    This final report for the Swiss Federal Office of Energy (SFOE) reports on the results of measurements made concerning the emission factors of two modern wood-pellet heating units under typical heating conditions. Using simulations, typical operation in single-family homes and apartment blocks were examined. Emissions during the different phases of operation were examined. Systems with and without buffer storage were also examined. The minimum running times to be striven for are quoted which would lead to a reduction of emissions to an acceptable level. The characteristic operating modes for the two heating units and the results obtained for various emissions are presented and discussed.

  11. Heat stress control in the TMI-2 [Three Mile Island Unit 2] defueling and decontamination activities

    Schork, J.S.; Parfitt, B.A.

    1988-01-01

    During the initial stages of the Three Mile Island Unit 2 (TMI-2) defueling and decontamination activities for the reactor building, it was realized that the high levels of loose radioactive contamination would require the use of extensive protective clothing by entry personnel. While there was no doubt that layered protective clothing protects workers from becoming contaminated, it was recognized that these same layers of clothing would impose a very significant heat stress burden. To prevent the potentially serious consequences of a severe reaction to heat stress by workers in the hostile environment of the TMI-2 reactor building and yet maintain the reasonable work productivity necessary to perform the recovery adequately, an effective program of controlling worker exposure to heat stress had to be developed. Body-cooling devices produce a flow of cool air, which is introduced close to the skin to remove body heat through convection and increased sweat evaporation. The cooling effect produced by the Vortex tube successfully protected the workers from heat stress, however, there were several logistical and operational problems that hindered extensive use of these devices. The last type of cooling garment examined was the frozen water garment (FWG) developed by Elizier Kamon at the Pennsylvania State University as part of an Electric Power Research Institute research grant. Personal protection, i.e., body cooling, engineering controls, and administrative controls, have been implemented successfully

  12. Heat transfer and thermal storage performance of an open thermosyphon type thermal storage unit with tubular phase change material canisters

    Wang, Ping-Yang; Hu, Bo-Wen; Liu, Zhen-Hua

    2015-01-01

    Highlights: • A novel open heat pipe thermal storage unit is design to improve its performance. • Mechanism of its operation is phase-change heat transfer. • Tubular canisters with phase change material were placed in thermal storage unit. • Experiment and analysis are carried out to investigate its operation properties. - Abstract: A novel open thermosyphon-type thermal storage unit is presented to improve design and performance of heat pipe type thermal storage unit. In the present study, tubular canisters filled with a solid–liquid phase change material are vertically placed in the middle of the thermal storage unit. The phase change material melts at 100 °C. Water is presented as the phase-change heat transfer medium of the thermal storage unit. The tubular canister is wrapped tightly with a layer of stainless steel mesh to increase the surface wettability. The heat transfer mechanism of charging/discharging is similar to that of the thermosyphon. Heat transfer between the heat resource or cold resource and the phase change material in this device occurs in the form of a cyclic phase change of the heat-transfer medium, which occurs on the surface of the copper tubes and has an extremely high heat-transfer coefficient. A series of experiments and theoretical analyses are carried out to investigate the properties of the thermal storage unit, including power distribution, start-up performance, and temperature difference between the phase change material and the surrounding vapor. The results show that the whole system has excellent heat-storage/heat-release performance

  13. Optimization model of a system of crude oil distillation units whit heat integration and meta modeling

    Lopez, Diana C; Mahecha, Cesar A; Hoyos, Luis J; Acevedo, Leonardo; Villamizar Jaime F

    2009-01-01

    The process of crude distillation impacts the economy of any refinery in a considerable manner. Therefore, it is necessary to improve it taking good advantage of the available infrastructure, generating products that conform to the specifications without violating the equipment operating constraints or plant restrictions at industrial units. The objective of this paper is to present the development of an optimization model for a Crude Distillation Unit (CDU) system at a ECOPETROL S.A. refinery in Barrancabermeja, involving the typical restrictions (flow according to pipeline capacity, pumps, distillation columns, etc) and a restriction that has not been included in bibliographic reports for this type of models: the heat integration of streams from Atmospheric Distillation Towers (ADTs) and Vacuum Distillation Towers (VDT) with the heat exchanger networks for crude pre-heating. On the other hand, ADTs were modeled with Meta models in function of column temperatures and pressures, pumparounds flows and return temperatures, stripping steam flows, Jet EBP ASTM D-86 and Diesel EBP ASTM D-86. Pre-heating trains were modeled with mass and energy balances, and design equation of each heat exchanger. The optimization model is NLP, maximizing the system profit. This model was implemented in GAMSide 22,2 using the CONOPT solver and it found new operating points with better economic results than those obtained with the normal operation in the real plants. It predicted optimum operation conditions of 3 ADTs for constant composition crude and calculated the yields and properties of atmospheric products, additional to temperatures and duties of 27 Crude Oil exchangers.

  14. Optimization model of a system of crude oil distillation units with heat integration and metamodeling

    Lopez, Diana C; Mahecha, Cesar A; Hoyos, Luis J; Acevedo, Leonardo; Villamizar Jaime F

    2010-01-01

    The process of crude distillation impacts the economy of any refinery in a considerable manner. Therefore, it is necessary to improve it taking good advantage of the available infrastructure, generating products that conform to the specifications without violating the equipment operating constraints or plant restrictions at industrial units. The objective of this paper is to present the development of an optimization model for a Crude Distillation Unit (CDU) system at a ECOPETROL S.A. refinery in Barrancabermeja, involving the typical restrictions (flow according to pipeline capacity, pumps, distillation columns, etc) and a restriction that has not been included in bibliographic reports for this type of models: the heat integration of streams from Atmospheric Distillation Towers (ADTs) and Vacuum Distillation Towers (VDT) with the heat exchanger networks for crude pre-heating. On the other hand, ADTs were modeled with Metamodels in function of column temperatures and pressures, pump a rounds flows and return temperatures, stripping steam flows, Jet EBP ASTM D-86 and Diesel EBP ASTM D-86. Pre-heating trains were modeled with mass and energy balances, and design equation of each heat exchanger. The optimization model is NLP, maximizing the system profit. This model was implemented in GAMSide 22,2 using the CONOPT solver and it found new operating points with better economic results than those obtained with the normal operation in the real plants. It predicted optimum operation conditions of 3 ADTs for constant composition crude and calculated the yields and properties of atmospheric products, additional to temperatures and duties of 27 Crude Oil exchangers.

  15. Sodium aerosol recovering device

    Fujimori, Koji; Ueda, Mitsuo; Tanaka, Kazuhisa.

    1997-01-01

    A main body of a recovering device is disposed in a sodium cooled reactor or a sodium cooled test device. Air containing sodium aerosol is sucked into the main body of the recovering device by a recycling fan and introduced to a multi-staged metal mesh filter portion. The air about against each of the metal mesh filters, and the sodium aerosol in the air is collected. The air having a reduced sodium aerosol concentration circulates passing through a recycling fan and pipelines to form a circulation air streams. Sodium aerosol deposited on each of the metal mesh filters is scraped off periodically by a scraper driving device to prevent clogging of each of the metal filters. (I.N.)

  16. METHOD OF RECOVERING URANIUM COMPOUNDS

    Poirier, R.H.

    1957-10-29

    S>The recovery of uranium compounds which have been adsorbed on anion exchange resins is discussed. The uranium and thorium-containing residues from monazite processed by alkali hydroxide are separated from solution, and leached with an alkali metal carbonate solution, whereby the uranium and thorium hydrorides are dissolved. The carbonate solution is then passed over an anion exchange resin causing the uranium to be adsorbed while the thorium remains in solution. The uranium may be recovered by contacting the uranium-holding resin with an aqueous ammonium carbonate solution whereby the uranium values are eluted from the resin and then heating the eluate whereby carbon dioxide and ammonia are given off, the pH value of the solution is lowered, and the uranium is precipitated.

  17. Global Warming Impacts on Heating and Cooling Degree-Days in the United States

    Petri, Y.; Caldeira, K.

    2014-12-01

    Anthropogenic climate change is expected to significantly alter residential air conditioning and space heating requirements, which account for 41% of U.S. household energy expenditures. The degree-day method can be used for reliable estimation of weather related building energy consumption and costs, as well as outdoor climatic thermal comfort. Here, we use U.S. Climate Normals developed by NOAA based on weather station observations along with Climate Model Intercomparison Project phase 5 (CMIP5) multi-model ensemble simulations. We add the projected change in heating and cooling degree-days based on the climate models to the estimates based on the NOAA U.S. Climate Normals to project future heating and cooling degree-days. We find locations with the lowest and highest combined index of cooling (CDDs) and heating degree-days (HDDs) for the historical period (1981 - 2010) and future period (2080 - 2099) under the Representation Concentration Pathway 8.5 (RCP8.5) climate change scenario. Our results indicate that in both time frames and among the lower 48 states, coastal areas in the West and South California will have the smallest degree-day sum (CDD + HDD), and hence from a climatic perspective become the best candidates for residential real estate. The Rocky Mountains region in Wyoming, in addition to northern Minnesota and North Dakota, will have the greatest CDD + HDD. While global warming is projected to reduce the median heating and cooling demand (- 5%) at the end of the century, CDD + HDD will decrease in the North, with an opposite effect in the South. This work could be helpful in deciding where to live in the United States based on present and future thermal comfort, and could also provide a basis for estimates of changes in heating and cooling energy demand.

  18. Heat Flow and Geothermal Potential in the South-Central United States

    Negraru, Petru T.; Blackwell, David D.; Erkan, Kamil

    2008-01-01

    Geothermal exploration is typically limited to high-grade hydrothermal reservoirs that are usually found in the western United States, yet large areas with subsurface temperatures above 150 deg. C at economic drilling depths can be found east of the Rocky Mountains. The object of this paper is to present new heat flow data and to evaluate the geothermal potential of Texas and adjacent areas. The new data show that, west of the Ouachita Thrust Belt, the heat flow values are lower than east of the fault zone. Basement heat flow values for the Palo Duro and Fort Worth Basins are below 50 mW/m 2 while, in the frontal zone of the belt, they can exceed 60 mW/m 2 . Further east, along the Balcones fault system the heat flow is in general higher than 55 mW/m 2 . The eastern most heat flow sites are in Louisiana and they show very high heat flow (over 80 mW/m 2 ), which is associated with the apparently highly radioactive basement of the Sabine uplift. The geothermal resource in this area is large and diverse, and can be divided in high grade (temperature above 150 deg. C) convective systems, conductive based enhanced geothermal systems and geothermal/geopressured systems. One of the most attractive areas east of the cordillera extends from eastern Texas across Louisiana and Arkansas to western Mississippi. Here temperatures reach exploitation range at depths below 4 km, and tapping such a resource from shut in hydrocarbon fields is relatively easy. The initial costs of the development can be greatly reduced if existing hydrocarbon infrastructure is used, and therefore using shut-in hydrocarbon fields for geothermal purposes should not be neglected

  19. The energy efficiency ratio of heat storage in one shell-and-one tube phase change thermal energy storage unit

    Wang, Wei-Wei; Wang, Liang-Bi; He, Ya-Ling

    2015-01-01

    Highlights: • A parameter to indicate the energy efficiency ratio of PCTES units is defined. • The characteristics of the energy efficiency ratio of PCTES units are reported. • A combined parameter of the physical properties of the working mediums is found. • Some implications of the energy efficiency ratio in design of PCTES units are analyzed. - Abstract: From aspect of energy consuming to pump heat transfer fluid, there is no sound basis on which to create an optimum design of a thermal energy storage unit. Thus, it is necessary to develop a parameter to indicate the energy efficiency of such unit. This paper firstly defines a parameter that indicates the ratio of heat storage of phase change thermal energy storage unit to energy consumed in pumping heat transfer fluid, which is called the energy efficiency ratio, then numerically investigates the characteristics of this parameter. The results show that the energy efficiency ratio can clearly indicate the energy efficiency of a phase change thermal energy storage unit. When the fluid flow of a heat transfer fluid is in a laminar state, the energy efficiency ratio is larger than in a turbulent state. The energy efficiency ratio of a shell-and-tube phase change thermal energy storage unit is more sensitive to the outer tube diameter. Under the same working conditions, within the heat transfer fluids studied, the heat storage property of the phase change thermal energy storage unit is best for water as heat transfer fluid. A combined parameter is found to indicate the effects of both the physical properties of phase change material and heat transfer fluid on the energy efficiency ratio

  20. Use of Artificial Neural Networks for Prediction of Convective Heat Transfer in Evaporative Units

    Romero-Méndez Ricardo

    2014-01-01

    Full Text Available Convective heat transfer prediction of evaporative processes is more complicated than the heat transfer prediction of single-phase convective processes. This is due to the fact that physical phenomena involved in evaporative processes are very complex and vary with the vapor quality that increases gradually as more fluid is evaporated. Power-law correlations used for prediction of evaporative convection have proved little accuracy when used in practical cases. In this investigation, neural-network-based models have been used as a tool for prediction of the thermal performance of evaporative units. For this purpose, experimental data were obtained in a facility that includes a counter-flow concentric pipes heat exchanger with R134a refrigerant flowing inside the circular section and temperature controlled warm water moving through the annular section. This work also included the construction of an inverse Rankine refrigeration cycle that was equipped with measurement devices, sensors and a data acquisition system to collect the experimental measurements under different operating conditions. Part of the data were used to train several neural-network configurations. The best neural-network model was then used for prediction purposes and the results obtained were compared with experimental data not used for training purposes. The results obtained in this investigation reveal the convenience of using artificial neural networks as accurate predictive tools for determining convective heat transfer rates of evaporative processes.

  1. Sizing Combined Heat and Power Units and Domestic Building Energy Cost Optimisation

    Dongmin Yu

    2017-06-01

    Full Text Available Many combined heat and power (CHP units have been installed in domestic buildings to increase energy efficiency and reduce energy costs. However, inappropriate sizing of a CHP may actually increase energy costs and reduce energy efficiency. Moreover, the high manufacturing cost of batteries makes batteries less affordable. Therefore, this paper will attempt to size the capacity of CHP and optimise daily energy costs for a domestic building with only CHP installed. In this paper, electricity and heat loads are firstly used as sizing criteria in finding the best capacities of different types of CHP with the help of the maximum rectangle (MR method. Subsequently, the genetic algorithm (GA will be used to optimise the daily energy costs of the different cases. Then, heat and electricity loads are jointly considered for sizing different types of CHP and for optimising the daily energy costs through the GA method. The optimisation results show that the GA sizing method gives a higher average daily energy cost saving, which is 13% reduction compared to a building without installing CHP. However, to achieve this, there will be about 3% energy efficiency reduction and 7% input power to rated power ratio reduction compared to using the MR method and heat demand in sizing CHP.

  2. Process and system for recovering energy

    Trichet, J.-C.

    1975-01-01

    The invention concerns a system for heating a room or similar, using a 'dibare' cycle working with a less volatile fluid and a more volatile fluid and employing a coupling between a fractionated separation area working at high pressure and a fractionated mixing zone working at low pressure. The invention relates to the following uses: heating a room or building, drying any material and recovering the thermal discharge from a motive cycle, particularly the recovery of the thermal discharge of an electric nuclear power station to carry out district heating [fr

  3. A basic study on Thermosyphon-type thermal storage unit (TSU) using Nanofluid as the heat transfer medium

    Li, Shuang-Fei; Wang, Ping-Yang; Liu, Zhen-hua

    2017-11-01

    This study proposed a novel thermosyphon-type thermal storage unit using water-based CuO nanofluid as the phase-change heat transfer medium. Seven tubular canisters containing solid-liquid phase-change material (PCM) with peak melting temperature of 100 °C were placed vertically into the center of the TSU which is a vertical cylindrical vessel made of stainless steel. Coat formed by depositing nanoparticles during the phase-change process was adopted to increase the wettability of the heat transfer surfaces of the canisters. We investigated the phase-change heat transfer, as well as the heat-storage and heat-release properties, of the TSU through experimental and computational analysis. Our results demonstrate that this thermal storage unit construction can propose good heat transfer and heat-storage/heat-release performance. The coating of nanoparticles onto the heat transfer surfaces increases the surface wettability and improves both the evaporation and condensation heat transfer. The main thermal resistance in the TSU results from the conductive heat transfer inside of the PCM. All phase-change thermal resistance of liquid film in charging and discharging processes can be ignored in this TSU.

  4. A basic study on Thermosyphon-type thermal storage unit (TSU) using Nanofluid as the heat transfer medium

    Li, Shuang-Fei; Wang, Ping-Yang; Liu, Zhen-hua

    2018-05-01

    This study proposed a novel thermosyphon-type thermal storage unit using water-based CuO nanofluid as the phase-change heat transfer medium. Seven tubular canisters containing solid-liquid phase-change material (PCM) with peak melting temperature of 100 °C were placed vertically into the center of the TSU which is a vertical cylindrical vessel made of stainless steel. Coat formed by depositing nanoparticles during the phase-change process was adopted to increase the wettability of the heat transfer surfaces of the canisters. We investigated the phase-change heat transfer, as well as the heat-storage and heat-release properties, of the TSU through experimental and computational analysis. Our results demonstrate that this thermal storage unit construction can propose good heat transfer and heat-storage/heat-release performance. The coating of nanoparticles onto the heat transfer surfaces increases the surface wettability and improves both the evaporation and condensation heat transfer. The main thermal resistance in the TSU results from the conductive heat transfer inside of the PCM. All phase-change thermal resistance of liquid film in charging and discharging processes can be ignored in this TSU.

  5. Recovering valuable liquid hydrocarbons

    Pier, M

    1931-06-11

    A process for recovering valuable liquid hydrocarbons from coking coal, mineral coal, or oil shale through treatment with hydrogen under pressure at elevated temperature is described. Catalysts and grinding oil may be used in the process if necessary. The process provides for deashing the coal prior to hydrogenation and for preventing the coking and swelling of the deashed material. During the treatment with hydrogen, the coal is either mixed with coal low in bituminous material, such as lean coal or active coal, as a diluent or the bituminous constituents which cause the coking and swelling are removed by extraction with solvents. (BLM)

  6. Cogeneration of heat and electricity from rape oil with a little CHP unit in a car wash

    Pilz, H.D.; Thomas, S.; Zeilinger, J.

    2002-01-01

    Environmentally friendly energy supply system for smaller houses is described. In Elsbett system the so-called multi fuel engine starts the combined electricity and heat production unit. In such a system one can use also natural fuels, animal oils and fats besides heating oil. Therefore no additional CO 2 is produced, but it will be brought to the balanced natural circle

  7. Heat waves in the United States: mortality risk during heat waves and effect modification by heat wave characteristics in 43 U.S. communities.

    Anderson, G Brooke; Bell, Michelle L

    2011-02-01

    Devastating health effects from recent heat waves, and projected increases in frequency, duration, and severity of heat waves from climate change, highlight the importance of understanding health consequences of heat waves. We analyzed mortality risk for heat waves in 43 U.S. cities (1987-2005) and investigated how effects relate to heat waves' intensity, duration, or timing in season. Heat waves were defined as ≥ 2 days with temperature ≥ 95th percentile for the community for 1 May through 30 September. Heat waves were characterized by their intensity, duration, and timing in season. Within each community, we estimated mortality risk during each heat wave compared with non-heat wave days, controlling for potential confounders. We combined individual heat wave effect estimates using Bayesian hierarchical modeling to generate overall effects at the community, regional, and national levels. We estimated how heat wave mortality effects were modified by heat wave characteristics (intensity, duration, timing in season). Nationally, mortality increased 3.74% [95% posterior interval (PI), 2.29-5.22%] during heat waves compared with non-heat wave days. Heat wave mortality risk increased 2.49% for every 1°F increase in heat wave intensity and 0.38% for every 1-day increase in heat wave duration. Mortality increased 5.04% (95% PI, 3.06-7.06%) during the first heat wave of the summer versus 2.65% (95% PI, 1.14-4.18%) during later heat waves, compared with non-heat wave days. Heat wave mortality impacts and effect modification by heat wave characteristics were more pronounced in the Northeast and Midwest compared with the South. We found higher mortality risk from heat waves that were more intense or longer, or those occurring earlier in summer. These findings have implications for decision makers and researchers estimating health effects from climate change.

  8. Recovering recyclable materials from shredder residue

    Jody, Bassam J.; Daniels, Edward J.; Bonsignore, Patrick V.; Brockmeier, Norman F.

    1994-02-01

    Each year, about 11 million tons of metals are recovered in the United States from about 10 million discarded automobiles. The recovered metals account for about 75 percent of the total weight of the discarded vehicles. The balance of the material, known as shredder residue, amounts to about three million tons annually and is currently landfilled. The residue contains a diversity of potentially recyclable materials, including polyurethane foams, iron oxides, and certain thermoplastics. This article discusses a process under development at Argonne National Laboratory to separate and recover the recyclable materials from this waste stream. The process consists essentially of two stages. First, a physical separation is used to recover the foams and the metal oxides, followed by a chemical process to extract certain thermoplastics. The status of the technology and the process economics are reviewed here.

  9. Flue gas moisture capacity calculation at the outlet of the condensation heat recovery unit

    Galashov Nikolay

    2017-01-01

    Full Text Available As a result, study equation has been obtained which determine the flue gas moisture capacity at the outlet of the condensation heat recovery unit with an error of less than 1%. It possible to at the temperature of the flue gas below the dew point and the known air-fuel ratio efficient. The equation can be used to calculate plants operating on products of gas combustion without Use of tables and programs for calculating the water-vapor saturation pressure.

  10. Discussion on application of water source heat pump technology to uranium mines

    An Qiang

    2011-01-01

    Application of water source heat pump units in recovering waste heat from uranium mines is discussed, and several forms of waste heat recovery are introduced. The problems in the application of water source heat pump technology are analyzed. Analysis results show that the water source heat pump technology has broad application prospects in uranium mines, and it is a way to exchange existing structure of heat and cold sources in uranium mines. (authors)

  11. Thermal Analysis of a Thermal Energy Storage Unit to Enhance a Workshop Heating System Driven by Industrial Residual Water

    Wenqiang Sun

    2017-02-01

    Full Text Available Various energy sources can be used for room heating, among which waste heat utilization has significantly improved in recent years. However, the majority of applicable waste heat resources are high-grade or stable thermal energy, while the low-grade or unstable waste heat resources, especially low-temperature industrial residual water (IRW, are insufficiently used. A thermal energy storage (TES unit with paraffin wax as a phase change material (PCM is designed to solve this problem in a pharmaceutical plant. The mathematical models are developed to simulate the heat storage and release processes of the TES unit. The crucial parameters in the recurrence formulae are determined: the phase change temperature range of the paraffin wax used is 47 to 56 °C, and the latent heat is 171.4 kJ/kg. Several thermal behaviors, such as the changes of melting radius, solidification radius, and fluid temperature, are simulated. In addition, the amount of heat transferred, the heat transfer rate, and the heat storage efficiency are discussed. It is presented that the medicine production unit could save 10.25% of energy consumption in the investigated application.

  12. Method of recovering hydrocarbons from oil shale

    Walton, D.K.; Slusser, M.S.

    1970-11-24

    A method is described for recovering hydrocarbons from an oil-shale formation by in situ retorting. A well penetrating the formation is heated and gas is injected until a pressure buildup within the well is reached, due to a decrease in the conductivity of naturally occurring fissures within the formation. The well is then vented, in order to produce spalling of the walls. This results in the formation of an enlarged cavity containing rubberized oil shale. A hot gas then is passed through the rubberized oil shale in order to retort hydrocarbons and these hydrocarbons are recovered from the well. (11 claims)

  13. Simulation and design of distillation units for treatment of sulfite pulping condensates to recover methanol and furfural. Part I. Incorporation with an evaporation unit and use of secondary steam

    Zacchi, G.; Aly, G.

    1979-06-01

    A distillation unit was simulated using DESTLA, a computer program for steady-state calculations of general multicomponent distillation units. Vapor-liquid and liquid-liquid equilibria were both computed by EQUIL, a computer program for computation and plotting of such equilibria. The simulations resulted in a distillation unit consisting of three columns. Energy consumed in the first column dominates the operating costs of the unit. The first of the three different alternatives studied for satisfying the energy requirements of the first column is presented. Incorporating the first column into an evaporation unit yields low steam consumption. However, a decrease in evaporation capacity due to the temperature drop in the first column and complex control design are the disadvantages associated with this alternative.

  14. Heat Mortality Versus Cold Mortality: A Study of Conflicting Databases in the United States.

    Dixon, P. G.; Brommer, D. M.; Hedquist, B. C.; Kalkstein, A. J.; Goodrich, G. B.; Walter, J. C.; Dickerson, C. C., IV; Penny, S. J.; Cerveny, R. S.

    2005-07-01

    Studies, public reports, news reports, and Web sites cite a wide range of values associated with deaths resulting from excessive heat and excessive cold. For example, in the United States, the National Climatic Data Center's Storm Data statistics of temperature- related deaths are skewed heavily toward heat-related deaths, while the National Center for Health Statistics Compressed Mortality Database indicates the reverse—4 times more people die of “excessive cold” conditions in a given year than of “excessive heat.” In this study, we address the fundamental differences in the various temperature-related mortality databases, assess their benefits and limitations, and offer suggestions as to their use. These datasets suffer from potential incompleteness of source information, long compilation times, limited quality control, and the subjective determination of a direct versus indirect cause of death. In general, these separate mortality datasets should not be combined or compared, particularly with regard to policy determination. The use of gross mortality numbers appears to be one of the best means of determining temperature-related mortality, but those data must be detrended into order to remove a persistent winter-dominant death maximum and are difficult to obtain on a regional daily basis.

  15. Impacts of global warming on residential heating and cooling degree-days in the United States.

    Petri, Yana; Caldeira, Ken

    2015-08-04

    Climate change is expected to decrease heating demand and increase cooling demand for buildings and affect outdoor thermal comfort. Here, we project changes in residential heating degree-days (HDD) and cooling degree-days (CDD) for the historical (1981-2010) and future (2080-2099) periods in the United States using median results from the Climate Model Intercomparison Project phase 5 (CMIP5) simulations under the Representation Concentration Pathway 8.5 (RCP8.5) scenario. We project future HDD and CDD values by adding CMIP5 projected changes to values based on historical observations of US climate. The sum HDD + CDD is an indicator of locations that are thermally comfortable, with low heating and cooling demand. By the end of the century, station median HDD + CDD will be reduced in the contiguous US, decreasing in the North and increasing in the South. Under the unmitigated RCP8.5 scenario, by the end of this century, in terms of HDD and CDD values considered separately, future New York, NY, is anticipated to become more like present Oklahoma City, OK; Denver, CO, becomes more like Raleigh, NC, and Seattle, WA, becomes more like San Jose, CA. These results serve as an indicator of projected climate change and can help inform decision-making.

  16. Experimental comparison between R409A and R437A performance in a heat pump unit

    Duarte M. V.

    2017-04-01

    Full Text Available This paper reports an experimental comparison between the use of the refrigerants R409A and R437A in a heat pump unit designed and developed to work with R12. Although the use of both refrigerants in new equipments were abolished in EU and US according the new F-Gas Regulation of EU and SNAP, they still being used as options for R12 in old equipments, especially in developing countries. Both refrigerants were studied for the same test conditions, according to two groups of tests: group A (variation of the heat source temperature and group B (variation of refrigerant flow rate. The results obtained showed that the R437A presents a higher discharge pressure and a lower discharge temperature. The heating and cooling capacities of both refrigerants were similar, as well as the exergetic efficiency. For the group A of tests the COP of both refrigerants was similar and for the group B of tests the R409A presented an average COP 15% higher. According to the results obtained it is recommended the use of R409A in old equipments (as transition refrigerant until the acquisition of equipments operating with refrigerants with low-GWP becomes technically and economic feasible.

  17. Impacts of global warming on residential heating and cooling degree-days in the United States

    Petri, Yana; Caldeira, Ken

    2015-01-01

    Climate change is expected to decrease heating demand and increase cooling demand for buildings and affect outdoor thermal comfort. Here, we project changes in residential heating degree-days (HDD) and cooling degree-days (CDD) for the historical (1981–2010) and future (2080–2099) periods in the United States using median results from the Climate Model Intercomparison Project phase 5 (CMIP5) simulations under the Representation Concentration Pathway 8.5 (RCP8.5) scenario. We project future HDD and CDD values by adding CMIP5 projected changes to values based on historical observations of US climate. The sum HDD + CDD is an indicator of locations that are thermally comfortable, with low heating and cooling demand. By the end of the century, station median HDD + CDD will be reduced in the contiguous US, decreasing in the North and increasing in the South. Under the unmitigated RCP8.5 scenario, by the end of this century, in terms of HDD and CDD values considered separately, future New York, NY, is anticipated to become more like present Oklahoma City, OK; Denver, CO, becomes more like Raleigh, NC, and Seattle, WA, becomes more like San Jose, CA. These results serve as an indicator of projected climate change and can help inform decision-making. PMID:26238673

  18. Analysis of chiller units capacity for different heat loads considering variation of ambient air and cooling water temperature

    Coman, Aurelia Camelia; Tenescu, Mircea

    2010-01-01

    The paper purpose is to analyze the chiller units capacity to determine whether they can cope with high air and cooling water temperatures during summer time to remove heat loads imposed from Heating, Ventilation and Air Conditioning (HVAC) units in a CANDU 6 Nuclear Power Plant. The starting point is calculation of the overall heat transfer coefficient at the evaporator and condenser. They are used in heat balance equations of heat exchangers. A mathematical model was developed that simulates the refrigeration cycle to assess the response of chilled water system and its performance at different heat loads. In this analysis there were calculated values for inlet/outlet chilled water temperature and the refrigerant cycle thermodynamic parameters (condenser and evaporator pressure/temperature, refrigerant mass flowrate, refrigerant quality at the evaporator, refrigerant vapour superheated temperature at the compressor outlet, refrigerant subcooled temperature at the condenser outlet). To find the adequate functioning parameters of the installation, the MathCAD 13 software was used in all cases analyzed. The behaviour of the chiller units was investigated by examining the variation of three basic parameters, namely: - cooling water (river water) temperature; - air temperature; - heat load. The simultaneous variation of these three independent parameters allows to identify the actual chillers unit operating point (including chiller trip). (authors)

  19. Process for recovering uranium

    MacWood, G. E.; Wilder, C. D.; Altman, D.

    1959-03-24

    A process useful in recovering uranium from deposits on stainless steel liner surfaces of calutrons is presented. The deposit is removed from the stainless steel surface by washing with aqueous nitric acid. The solution obtained containing uranium, chromium, nickel, copper, and iron is treated with an excess of ammonium hydroxide to precipitnte the uranium, iron, and chromium and convert the nickel and copper to soluble ammonio complexions. The precipitated material is removed, dried and treated with carbon tetrachloride at an elevated temperature of about 500 to 600 deg C to form a vapor mixture of UCl/ sub 4/, UCl/sub 5/, FeCl/sub 3/, and CrCl/sub 4/. The UCl/sub 4/ is separated from this vapor mixture by selective fractional condensation at a temperature of about 500 to 400 deg C.

  20. Cooling energy efficiency and classroom air environment of a school building operated by the heat recovery air conditioning unit

    Wang, Yang; Zhao, Fu-Yun; Kuckelkorn, Jens; Liu, Di; Liu, Li-Qun; Pan, Xiao-Chuan

    2014-01-01

    The recently-built school buildings have adopted novel heat recovery ventilator and air conditioning system. Heat recovery efficiency of the heat recovery facility and energy conservation ratio of the air conditioning unit were analytically modeled, taking the ventilation networks into account. Following that, school classroom displacement ventilation and its thermal stratification and indoor air quality indicated by the CO 2 concentration have been numerically modeled concerning the effects of delivering ventilation flow rate and supplying air temperature. Numerical results indicate that the promotion of mechanical ventilation rate can simultaneously boost the dilution of indoor air pollutants and the non-uniformity of indoor thermal and pollutant distributions. Subsequent energy performance analysis demonstrates that classroom energy demands for ventilation and cooling could be reduced with the promotion of heat recovery efficiency of the ventilation facility, and the energy conservation ratio of the air conditioning unit decreases with the increasing temperatures of supplying air. Fitting correlations of heat recovery ventilation and cooling energy conservation have been presented. - Highlights: • Low energy school buildings and classroom environment. • Heat recovery facility operating with an air conditioning unit. • Displacement ventilation influenced by the heat recovery efficiency. • Energy conservation of cooling and ventilation through heat recovery. • Enhancement of classroom environment with reduction of school building energy

  1. Regional implications of heat flow of the Snake River Plain, Northwestern United States

    Blackwell, D. D.

    1989-08-01

    The Snake River Plain is a major topographic feature of the Northwestern United States. It marks the track of an upper mantle and crustal melting event that propagated across the area from southwest to northeast at a velocity of about 3.5 cm/yr. The melting event has the same energetics as a large oceanic hotspot or plume and so the area is the continental analog of an oceanic hotspot track such as the Hawaiian Island-Emperor Seamount chain. Thus, the unique features of the area reflect the response of a continental lithosphere to a very energetic hotspot. The crust is extensively modified by basalt magma emplacement into the crust and by the resulting massive rhyolite volcanism from melted crustal material, presently occurring at Yellowstone National Park. The volcanism is associated with little crustal extension. Heat flow values are high along the margins of the Eastern and Western Snake River Plains and there is abundant evidence for low-grade geothermal resources associated with regional groundwater systems. The regional heat flow pattern in the Western Snake River Plains reflects the influence of crustal-scale thermal refraction associated with the large sedimentary basin that has formed there. Heat flow values in shallow holes in the Eastern Snake River Plains are low due to the Snake River Plains aquifer, an extensive basalt aquifer where water flow rates approach 1 km/yr. Below the aquifer, conductive heat flow values are about 100 mW m -2. Deep holes in the region suggest a systematic eastward increase in heat flow in the Snake River Plains from about 75-90 mW m -2 to 90-110 mW m -2. Temperatures in the upper crust do not behave similarly because the thermal conductivity of the Plio-Pleistocene sedimentary rocks in the west is lower than that in the volcanic rocks characteristic of the Eastern Snake River Plains. Extremely high heat loss values (averaging 2500 mW m -2) and upper crustal temperatures are characteristic of the Yellowstone caldera.

  2. Climate Change and Health Risks from Extreme Heat and Air Pollution in the Eastern United States

    Limaye, V.; Vargo, J.; Harkey, M.; Holloway, T.; Meier, P.; Patz, J.

    2013-12-01

    Climate change is expected to exacerbate health risks from exposure to extreme heat and air pollution through both direct and indirect mechanisms. Directly, warmer ambient temperatures promote biogenic emissions of ozone precursors and favor the formation of ground-level ozone, while an anticipated increase in the frequency of stagnant air masses will allow fine particulates to accumulate. Indirectly, warmer summertime temperatures stimulate energy demand and exacerbate polluting emissions from the electricity sector. Thus, while technological adaptations such as air conditioning can reduce risks from exposures to extreme heat, they can trigger downstream damage to air quality and public health. Through an interdisciplinary modeling effort, we quantify the impacts of climate change on ambient temperatures, summer energy demand, air quality, and public health. The first phase of this work explores how climate change will directly impact the burden of heat-related mortality. Climatic patterns, demographic trends, and epidemiologic risk models suggest that populations in the eastern United States are likely to experience an increasing heat stress mortality burden in response to rising summertime air temperatures. We use North American Regional Climate Change Assessment Program modeling data to estimate mid-century 2-meter air temperatures and humidity across the eastern US from June-August, and quantify how long-term changes in actual and apparent temperatures from present-day will affect the annual burden of heat-related mortality across this region. With the US Environmental Protection Agency's Environmental Benefits Mapping and Analysis Program, we estimate health risks using concentration-response functions, which relate temperature increases to changes in annual mortality rates. We compare mid-century summertime temperature data, downscaled using the Weather Research and Forecasting model, to 2007 baseline temperatures at a 12 km resolution in order to estimate

  3. Loss of residual heat removal system: Diablo Canyon, Unit 2, April 10, 1987

    1987-06-01

    This report presents the findings of an NRC Augmented Inspection Team (AIT) investigation into the circumstances associated with the loss of residual heat removal (RHR) system capability for a period of approximately one and one-half hours at the Diablo Canyon, Unit 2 reactor facility on April 10, 1987. This event occurred while the Diablo Canyon, Unit 2, a pressurized water reactor, was shutdown with the reactor coolant system (RCS) water level drained to approximately mid-level of the hot leg piping. The reactor containment building equipment hatch was removed at the time of the event, and plant personnel were in the process of removing the primary side manways to gain access into the steam generator channel head areas. Thus, two fission product barriers were breached throughout the event. The RCS temperature increased from approximately 87 0 F to bulk boiling conditions without RCS temperature indication available to the plant operators. The RCS was subsequently pressurized to approximately 7 to 10 psig. The NRC AIT members concluded that the Diablo Canyon, Unit 2 plant was, at the time of the event, in a condition not previously analyzed by the NRC staff. The AIT findings from this event appear significant and generic to other pressurized water reactor facilities licensed by the NRC

  4. Project recovers free wasted energy from an OSB dryer while eliminating a hog boiler

    Normandin, A.; Levesque, S.; Laflamme, Y.; Charron, R. [Mesar-Environair Inc., Quebec, PQ (Canada)

    2008-09-15

    This article described how a mill producing oriented strand board (OSB) in Quebec optimized its energy balance with the installation of a flue gas heat recovery (FGHR) system developed by Mesar-Environair Inc. Many OSB mills produce enough wood waste heat to supply their hog boilers with valuable, yet inexpensive, fuel. The objective of this project was to recover waste heat and to find an application in the milling process to re-valorize it. The plant was using 3 hog boilers to heat thermal oil for their process, but only the newest hog boiler was in compliance for particulate emissions levels. The solution involved the use of a direct contact heat exchanger to meet the mill's requirements. The process consisted of pumping the log pond water in a counter-current direction to the humid OSB dryer flue gas. The energy was transferred from the gas to the water via vapor condensation. The customized equipment recovered most of the wasted heat and transferred it to the plant's log ponds. Cool process water from the log ponds was then recirculated through the condenser to trap the wasted energy. The efficiency of the main hog boiler and the chip dry was about 80 per cent. The FGHR process was designed to recover 85 per cent of the wasted energy that was directed to the atmosphere. The heat recovery unit can typically generate temperatures of 70 to 80 degrees C. In addition to fewer emissions of carbon dioxide and nitrogen oxides going out the stack, the FGHR system offers the advantages of heating the process water without additional fuel, and shutting down an old hog boiler. 1 tabs., 3 figs.

  5. Experimental characterization, modeling and simulation of a wood pellet micro-combined heat and power unit used as a heat source for a residential building

    Thiers, Stephane; Aoun, Bernard; Peuportier, Bruno [MINES ParisTech, CEP - Centre Energetique et Procedes, 60 Boulevard St Michel, 75272 Paris Cedex 06 (France)

    2010-06-15

    Cogeneration provides heat and power in a more efficient way than separate production. Micro-cogeneration (micro-CHP) is an emerging solution for the improvement of energy and environmental assessments of residential buildings. A wood pellet Stirling engine micro-CHP unit has been studied in order to characterize its annual performance when integrated to a building. First, through a test bench experiment, both transient and steady state behaviors of the micro-CHP unit have been characterized and modeled. Then a more complete model representing a hot water and heating system including the micro-CHP unit and a stratified storage tank has been carried out. This model has been coupled to a building model. A sensitivity analysis by simulation shows that the dimensioning of different elements of the system strongly influences its global energy performance. (author)

  6. Optimum Design of Heat Exchangers Networks Part-2: case study: Atmospheric Crude Distillation Unit

    Gabr, E.M.A.; EI-Temtamy, S.A.; Deriasl, S.F.; Moustafa, H.A.

    2004-01-01

    In this paper the computerized framework introduced in part-I for Heat Exchanger Network Synthesis (HENS) with optimality conditions of achieving the least operating and capital cost has been applied on an industrial atmospheric distillation unit existing in one of the Egyptian refineries . The application includes two types of designing: grass-root and revamp of the existing design. For the final grass-root design, the saving of utilities is 50% of the actual consumption while the net annual saving reaches 2,193,690 S/year .For revamping of existing design the % saving of hot and cold utilities are 38.1% and 43.2% respectively and the annual saving of 1,723,104 $/year is achieved

  7. Experimental investigation on AC unit integrated with sensible heat storage (SHS)

    Aziz, N. A.; Amin, N. A. M.; Majid, M. S. A.; Hussin, A.; Zhubir, S.

    2017-10-01

    The growth in population and economy has increases the energy demand and raises the concerns over the sustainable energy source. Towards the sustainable development, energy efficiency in buildings has become a prime objective. In this paper, the integration of thermal energy storage was studied. This paper presents an experimental investigation on the performance of an air conditioning unit integrated with sensible heat storage (SHS) system. The results were compared to the conventional AC systems in the terms of average electricity usage, indoor temperature and the relative humidity inside the experimented room (cabin container). Results show that the integration of water tank as an SHS reduces the electricity usage by 5%, while the integration of well-insulated water tank saves up to 8% of the electricity consumption.

  8. Non-linear advanced control of the LHC inner triplet heat exchanger test unit

    Vinuela, E. Blanco; Cubillos, J. Casas; Prada Moraga, C. de; Cristea, S.

    2002-01-01

    The future Large Hadron Collider (LHC) at CERN will include eight interaction region final focus magnet systems, the so-called 'Inner Triplet', one on each side of the four beam collision points. The Inner Triplets will be cooled in a static bath of pressurized He II nominally at 1.9 K. This temperature is a control parameter and has very severe constraints in order to avoid the transition from the superconducting to normal resistive state. The main difference in these special zones with respect to a regular LHC cell is higher dynamic heat load unevenly distributed which modifies largely the process characteristics and hence the controller performance. Several control strategies have already been tested at CERN in a pilot plant (LHC String Test) which reproduced a LHC half-cell. In order to validate a common control structure along the whole LHC ring, a Nonlinear Model Predictive Control (NMPC) has been developed and implemented in the Inner Triplet Heat Exchanger Unit (IT-HXTU) at CERN. Automation of the Inner Triplet setup and the advanced control techniques deployed based on the Model Based Predictive Control (MBPC) principle are presented

  9. Stochastic Multicriteria Acceptability Analysis for Evaluation of Combined Heat and Power Units

    Haichao Wang

    2014-12-01

    Full Text Available Combined heat and power (CHP is a promising technology that can contribute to energy efficiency and environmental protection. More CHP-based energy systems are planned for the future. This makes the evaluation and selection of CHP systems very important. In this paper, 16 CHP units representing different technologies are taken into account for multicriteria evaluation with respect to the end users’ requirements. These CHP technologies cover a wide range of power outputs and fuel types. They are evaluated from the energy, economy and environment (3E points of view, specifically including the criteria of efficiency, investment cost, electricity cost, heat cost, CO2 production and footprint. Uncertainties and imprecision are common both in criteria measurements and weights, therefore the stochastic multicriteria acceptability analysis (SMAA model is used in aiding this decision making problem. These uncertainties are treated better using a probability distribution function and Monte Carlo simulation in the model. Moreover, the idea of “feasible weight space (FWS” which represents the union of all preference information from decision makers (DMs is proposed. A complementary judgment matrix (CJM is introduced to determine the FWS. It can be found that the idea of FWS plus CJM is well compatible with SMAA and thus make the evaluation reliable.

  10. District space heating potential of low temperature hydrothermal geothermal resources in the southwestern United States. Technical report

    McDevitt, P.K.; Rao, C.R.

    1978-10-01

    A computer simulation model (GIRORA-Nonelectric) is developed to study the economics of district space heating using geothermal energy. GIRORA-Nonelectric is a discounted cashflow investment model which evaluates the financial return on investment for space heating. This model consists of two major submodels: the exploration for and development of a geothermal anomaly by a geothermal producer, and the purchase of geothermal fluid by a district heating unit. The primary output of the model is a calculated rate of return on investment earned by the geothermal producer. The results of the sensitivity analysis of the model subject to changes in physical and economic parameters are given in this report. Using the results of the economic analysis and technological screening criteria, all the low temperature geothermal sites in Southwestern United States are examined for economic viability for space heating application. The methodology adopted and the results are given.

  11. Clonal diversity and detection of carbapenem resistance encoding genes among multidrug-resistant Acinetobacter baumannii isolates recovered from patients and environment in two intensive care units in a Moroccan hospital

    Jean Uwingabiye

    2017-09-01

    Full Text Available Abstract Background Carbapenem-resistant Acinetobacter baumannii has recently been defined by the World Health Organization as a critical pathogen. The aim of this study was to compare clonal diversity and carbapenemase-encoding genes of A. baumannii isolates collected from colonized or infected patients and hospital environment in two intensive care units (ICUs in Morocco. Methods The patient and environmental sampling was carried out in the medical and surgical ICUs of Mohammed V Military teaching hospital from March to August 2015. All A. baumannii isolates recovered from clinical and environmental samples, were identified using routine microbiological techniques and Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry. Antimicrobial susceptibility testing was performed using disc diffusion method. The carbapenemase-encoding genes were screened for by PCR. Clonal relatedness was analyzed by digestion of the DNA with low frequency restriction enzymes and pulsed field gel electrophoresis (PFGE and the multi locus sequence typing (MLST was performed on two selected isolates from two major pulsotypes. Results A total of 83 multidrug-resistant A. baumannii isolates were collected: 47 clinical isolates and 36 environmental isolates. All isolates were positive for the bla OXA51-like and bla OXA23-like genes. The coexistence of bla NDM-1 /bla OXA-23-like and bla OXA 24-like /bla OXA-23-like were detected in 27 (32.5% and 2 (2.4% of A. baumannii isolates, respectively. The environmental samples and the fecally-colonized patients were significantly identified (p < 0.05 as the most common sites of isolation of NDM-1-harboring isolates. PFGE grouped all isolates into 9 distinct clusters with two major groups (0007 and 0008 containing up to 59% of the isolates. The pulsotype 0008 corresponds to sequence type (ST 195 while pulsotype 0007 corresponds to ST 1089.The genetic similarity between the clinical and environmental isolates

  12. The critical role of extreme heat for maize production in the United States

    Lobell, David B.; Hammer, Graeme L.; McLean, Greg; Messina, Carlos; Roberts, Michael J.; Schlenker, Wolfram

    2013-05-01

    Statistical studies of rainfed maize yields in the United States and elsewhere have indicated two clear features: a strong negative yield response to accumulation of temperatures above 30°C (or extreme degree days (EDD)), and a relatively weak response to seasonal rainfall. Here we show that the process-based Agricultural Production Systems Simulator (APSIM) is able to reproduce both of these relationships in the Midwestern United States and provide insight into underlying mechanisms. The predominant effects of EDD in APSIM are associated with increased vapour pressure deficit, which contributes to water stress in two ways: by increasing demand for soil water to sustain a given rate of carbon assimilation, and by reducing future supply of soil water by raising transpiration rates. APSIM computes daily water stress as the ratio of water supply to demand, and during the critical month of July this ratio is three times more responsive to 2°C warming than to a 20% precipitation reduction. The results suggest a relatively minor role for direct heat stress on reproductive organs at present temperatures in this region. Effects of elevated CO2 on transpiration efficiency should reduce yield sensitivity to EDD in the coming decades, but at most by 25%.

  13. Experimental study of enhancing heating performance of the air-source heat pump by using a novel heat recovery device designed for reusing the energy of the compressor shell

    Huang, Bi; Jian, Qifei; Luo, Lizhong; Zhao, Jing

    2017-01-01

    Highlights: • A novel heat recovery device was designed and tested. • Aiming at avoiding liquid slugging in cold areas. • Recovery of the waste energy of compressor housing. • Refrigerant is heated with the energy recovered before it is sucked into the compressor. • Requires no extra power while the recovery system is operating. - Abstract: A novel heat recovery device designed to recover the heat that is released from the outer surface of heat pump compressors, and to enhance the performance of heat pumps in cold areas was made and tested in this study. The novel heat recovery device consists of three fundamental units: a heat absorption unit, a heat emission unit and heat pipes. An amount of work focused on recovering the heat of compressors through oil system, but few studies concentrated on the housing. The main advantage of the heat recovery device is no need for extra energy consumption for its only driving force is the temperature difference between the compressor shell and the working fluid inside the suction line. The experimental results were obtained from a series of tests with a R410A air-source heat pump. Effects of the device are analyzed with respect of the suction temperature, temperature distribution among the housing, input power and exergy destruction. Moreover, the impact on the heating capacity is also discussed. Further, direction for improvement is also given based on the analysis.

  14. Thermal performance evaluation of a latent heat storage unit for late evening cooking in a solar cooker having three reflectors

    Buddhi, D.; Sharma, A. [Devi Ahilya University, Indore (India). School of Energy and Environmental Studies, Thermal Energy Storage Laboratory; Sharma, S.D. [Mie University, Tsu (Japan). Faculty of Engineering, Department of Architecture

    2003-04-01

    In this paper, a phase change material (PCM) storage unit for a solar cooker was designed and developed to store energy during sunshine hours. The stored energy was utilised to cook food in the late evening. Commercial grade acetanilide (melting point 118.9 {sup o}C, latent heat of fusion 222 kJ/kg) was used as a latent heat storage material. Evening cooking experiments were conducted with different loads and loading times during the winter season. The experimental results showed that late evening cooking is possible in a solar cooker having three reflectors to enhance the incident solar radiation with the PCM storage unit. (author)

  15. Cernavoda NPP Unit 1: Ensuring heat sink at very low Danube river levels

    Urjan, D.

    2005-01-01

    Full text: On August 24, 2003 the summer heat wave has caused the Danube River to drop to its lowest level in more than a century, forcing a government commission of experts and a team of technical specialists from Cernavoda NPP to close Romania's unique nuclear reactor in operation at Cernavoda. The paper presents some of the required actions needed for plant shutdown and ensuring adequate fuel cooling at very low suction bay levels, due to the Danube River level drop (Danube waters cools the reactor). The water level in the Danube River at Cernavoda village, where the reactor is located, fell to a depth of less than three meters (10 feet) on Saturday, down from its usual level of almost seven meters (23 feet). Consequently, the Unit 1 nuclear power plant was shut down Sunday due to this record drought, which left insufficient water to cool down the reactor. Operating Instruction procedures were elaborated in order to provide a logical sequence of actions when the bay level decreases under 2.25 m, or the estimated level after 3 days will be lower than 1.8 m. When Raw Service Water (RSW) is lost, Recirculated Cooling Water (RCW) will remain in service only for Moderator, ESC, HT Pumps, HT Purification, D/C Cooler, LAC's, and D 2 O Feed Pump. Alternate water sources, like potable water and water from the fire protection system were taken in consideration in order to ensure heat sink to the RCW loads. At the same time, in case of total loss of Class III and Class IV Power, and Stand-By Diesel Generators unavailable because of the loss of heat sink provided by the RSW, Emergency Power System (EPS) was configured to supply directly the Class III Power 6 kV bus (BUG bus). Economical Impact According to a report, closing the nuclear plant costs Romania $500,000 a day. The total cost includes also losses due to a 40 percent reduction in hydroelectric power generation due to reduced river flow. The country had to cease power exports until the reactor comes back on line

  16. Development of a unit suitable for corrosion monitoring in district heating systems. Experiences with the LOCOR-cell test method

    Andersen, Asbjørn; Hilbert, Lisbeth Rischel

    2004-01-01

    A by-pass unit suitable for placement of a number of different probes for corrosion monitoring has been designed. Also measurements of water parameters are allowed in a side stream from the unit. The project is a part of the Nordic Innovation Fund project KORMOF. The by-pass unit has been installed...... in 6 pressurised circulating heating systems and in one cooling system. 7 different corrosion monitoring methods have been used to study corrosion rates and types in dependency of water chemistry. This paper describes the design of the by-pass unit including water analysis methods. It also describes...... the purpose, background and gained results of one of the used monitoring techniques, the crevice corrosion measurements obtained by the LOCOR-Cell„§. The crevice corrosion cell was developed by FORCE Technology in a previous district heating project financed by Nordic Industrial Fund (1)(2). Results from...

  17. Study of regeneration system of 300 MW power unit based on nondeaerating heat balance diagram at reduced load

    Esin, S. B.; Trifonov, N. N.; Sukhorukov, Yu. G.; Yurchenko, A. Yu.; Grigor'eva, E. B.; Snegin, I. P.; Zhivykh, D. A.; Medvedkin, A. V.; Ryabich, V. A.

    2015-09-01

    More than 30 power units of thermal power stations, based on the nondeaerating heat balance diagram, successfully operate in the former Soviet Union. Most of them are power units with a power of 300 MW, equipped with HTGZ and LMZ turbines. They operate according to a variable electric load curve characterized by deep reductions when undergoing night minimums. Additional extension of the range of power unit adjustment makes it possible to maintain the dispatch load curve and obtain profit for the electric power plant. The objective of this research is to carry out estimated and experimental processing of the operating regimes of the regeneration system of steam-turbine plants within the extended adjustment range and under the conditions when the constraints on the regeneration system and its equipment are removed. Constraints concerning the heat balance diagram that reduce the power unit efficiency when extending the adjustment range have been considered. Test results are presented for the nondeaerating heat balance diagram with the HTGZ turbine. Turbine pump and feed electric pump operation was studied at a power unit load of 120-300 MW. The reliability of feed pump operation is confirmed by a stable vibratory condition and the absence of cavitation noise and vibration at a frequency that characterizes the cavitation condition, as well as by oil temperature maintenance after bearings within normal limits. Cavitation performance of pumps in the studied range of their operation has been determined. Technical solutions are proposed on providing a profitable and stable operation of regeneration systems when extending the range of adjustment of power unit load. A nondeaerating diagram of high-pressure preheater (HPP) condensate discharge to the mixer. A regeneration system has been developed and studied on the operating power unit fitted with a deaeratorless thermal circuit of the system for removing the high-pressure preheater heating steam condensate to the mixer

  18. Preprototype vapor compression distillation subsystem. [recovering potable water from wastewater

    Ellis, G. S.; Wynveen, R. A.; Schubert, F. H.

    1979-01-01

    A three-person capacity preprototype vapor compression distillation subsystem for recovering potable water from wastewater aboard spacecraft was designed, assembled, and tested. The major components of the subsystem are: (1) a distillation unit which includes a compressor, centrifuge, central shaft, and outer shell; (2) a purge pump; (3) a liquids pump; (4) a post-treat cartridge; (5) a recycle/filter tank; (6) an evaporator high liquid level sensor; and (7) the product water conductivity monitor. A computer based control monitor instrumentation carries out operating mode change sequences, monitors and displays subsystem parameters, maintains intramode controls, and stores and displays fault detection information. The mechanical hardware occupies 0.467 m3, requires 171 W of electrical power, and has a dry weight of 143 kg. The subsystem recovers potable water at a rate of 1.59 kg/hr, which is equivalent to a duty cycle of approximately 30% for a crew of three. The product water has no foul taste or odor. Continued development of the subsystem is recommended for reclaiming water for human consumption as well as for flash evaporator heat rejection, urinal flushing, washing, and other on-board water requirements.

  19. Application and design of an economizer for waste heat recovery in a cogeneration plant

    Martić Igor I.

    2016-01-01

    Full Text Available Energy increase cost has required its more effective use. However, many industrial heating processes generate waste energy. Use of waste-heat recovery systems decreases energy consumption. This paper presents case study of waste heat recovering of the exhaust flue gas in a 1415 kWe cogeneration plant. This waste heat can be recovered by installing an economizer to heat the condensed and fresh water in thermal degasification unit and reduce steam use for maintaining the temperature of 105˚C for oxygen removal. Design methodology of economizer is presented.

  20. 40 CFR 75.81 - Monitoring of Hg mass emissions and heat input at the unit level.

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Monitoring of Hg mass emissions and... AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTINUOUS EMISSION MONITORING Hg Mass Emission Provisions § 75.81 Monitoring of Hg mass emissions and heat input at the unit level. The owner or operator of the...

  1. Development of a new distillation unit combined with compressed heat pump (heat integrated distillation column (HIDiC)) (eco-energy city project)

    Nakanishi, Toshinari; Aso, Kazumasa [Kimura Chemical Plants Co., Ltd., Amagasaki City, Hyogo (Japan); Takamatsu, Takeichiro [Research Inst. of Industrial Technology, Suita-City, Osaka (Japan); Nakaiwa, Masaru [National Inst. of Materials and Chemical Research, Tsukuba, Ibaraki (Japan); Noda, Hideo; Kuratani, Nobuyuki [Kansai Chemical Engineearing Co., Ltd., Amagasaki-city, Hyogo (Japan); Yoshida, Kazufumi [Maruzen Petrochemical Co., Ltd., 25-10, Tokyo (Japan)

    1999-07-01

    To reduce the irreversible loss the Heat Integrated Distillation Column (HIDiC) is proposed by application of heat-pump technology. (Distillation column, which is an energy consuming separation unit, has been widely used in oil refinery and the other chemical-related plants. The reason why it is a major energy consumer is that a large amount of irreversible loss occurs in heat transfer within the process.) In this paper, current results on the study of HIDiC in both simulations and experiments are shown. HIDiC must be operated at a higher pressure in the rectifying section so as to make its temperature higher than that of the stripping section which stands parallel with the rectifying section. That makes heat transfer from the rectifying section to the stripping section. Because of vaporization in the stripping section and condensation in the rectifying section, the energy for the reboiler can be saved. The degree of energy saving can be expected to be much more than 30%, although the exact value depends on the characteristics of mixture to be separated. (The degree of energy saving is higher than the above, if the exhaust vapor from the HIDiC is used to heat the feed or the other processes.) To save energy by the HIDiC, high separation performances and heat transfer capabilities are required. It has been found out that the HIDiC, whose shape is like vertical shell and tube heat exchanger was enough to be practical use of the HIDiC from the static design principle points of view. (orig.)

  2. Behavior of copper corrosion products in water loops of heat-exchange units

    Zarembo, V.I.; Kritskii, V.G.; Slobodov, A.A.; Puchkov, L.V.

    1989-01-01

    This communication is dedicated to an examination of copper corrosion products (CP) in the conditions of real aqueous-chemical regime (ACR) parameters. The deposition of these CP in steam-generating zones (up to 85% of their total amount) stimulate local types of corrosion. The solubility in Cu CP (Cu 2 O, CuO, Cu(OH) 2 )-water (H 2 O)-gas (H 2 , O 2 )-conditioning additives (HCl, KOH) systems was determined by computer modeling according to the minimum Gibbs energy criterion on the basis of selected and matched thermodynamic constants for various chemical forms of copper under standard conditions. As a result of the authors' calculations they obtained the solubilities in water of CuO, Cu 2 O and Cu(OH) 2 when changing the dosage of active gases from 0 to 10 -2 mole/kg of water, of acid or equal to that of saturated vapor of pure water. Thus, they were able to monitor the behavior of copper CP in conditions modeling those of real ACR in operating heat exchange units, including in conditions deviating from the standard

  3. Optical Coating Performance and Thermal Structure Design for Heat Reflectors of JWST Electronic Control Unit

    Quijada, Manuel A.; Threat, Felix; Garrison, Matt; Perrygo, Chuck; Bousquet, Robert; Rashford, Robert

    2008-01-01

    The James Webb Space Telescope (JWST) consists of an infrared-optimized Optical Telescope Element (OTE) that is cooled down to 40 degrees Kelvin. A second adjacent component to the OTE is the Integrated Science Instrument Module, or ISIM. This module includes the electronic compartment, which provides the mounting surfaces and ambient thermally controlled environment for the instrument control electronics. Dissipating the 200 watts generated from the ISIM structure away from the OTE is of paramount importance so that the spacecraft's own heat does not interfere with the infrared light detected from distant cosmic sources. This technical challenge is overcome by a thermal subsystem unit that provides passive cooling to the ISIM control electronics. The proposed design of this thermal radiator consists of a lightweight structure made out of composite materials and low-emittance metal coatings. In this paper, we will present characterizations of the coating emittance, bidirectional reflectance, and mechanical structure design that will affect the performance of this passive cooling system.

  4. Energy-Efficient Supermarket Heating, Ventilation, and Air Conditioning in Humid Climates in the United States

    Clark, J. [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2015-03-01

    Supermarkets are energy-intensive buildings that consume the greatest amount of electricity per square foot of building of any building type in the United States and represent 5% of total U.S. commercial building primary energy use (EIA 2005). Refrigeration and heating, ventilation, and air-conditioning (HVAC) systems are responsible for a large proportion of supermarkets’ total energy use. These two systems sometimes work together and sometimes compete, but the performance of one system always affects the performance of the other. To better understand these challenges and opportunities, the Commercial Buildings team at the National Renewable Energy Laboratory investigated several of the most promising strategies for providing energy-efficient HVAC for supermarkets and quantified the resulting energy use and costs using detailed simulations. This research effort was conducted on behalf of the U.S. Department of Energy (DOE) Commercial Building Partnerships (CBP) (Baechler et al. 2012; Parrish et al. 2013; Antonopoulos et al. 2014; Hirsch et al. 2014). The goal of CBP was to reduce energy use in the commercial building sector by creating, testing, and validating design concepts on the pathway to net zero energy commercial buildings. Several CBP partners owned or operated buildings containing supermarkets and were interested in optimizing the energy efficiency of supermarket HVAC systems in hot-humid climates. These partners included Walmart, Target, Whole Foods Market, SUPERVALU, and the Defense Commissary Agency.

  5. Optimal coordinated scheduling of combined heat and power fuel cell, wind, and photovoltaic units in micro grids considering uncertainties

    Bornapour, Mosayeb; Hooshmand, Rahmat-Allah; Khodabakhshian, Amin; Parastegari, Moein

    2016-01-01

    In this paper, a stochastic model is proposed for coordinated scheduling of combined heat and power units in micro grid considering wind turbine and photovoltaic units. Uncertainties of electrical market price; the speed of wind and solar radiation are considered using a scenario-based method. In the method, scenarios are generated using roulette wheel mechanism based on probability distribution functions of input random variables. Using this method, the probabilistic specifics of the problem are distributed and the problem is converted to a deterministic one. The type of the objective function, coordinated scheduling of combined heat and power, wind turbine, and photovoltaic units change this problem to a mixed integer nonlinear one. Therefore to solve this problem modified particle swarm optimization algorithm is employed. The mentioned uncertainties lead to an increase in profit. Moreover, the optimal coordinated scheduling of renewable energy resources and thermal units in micro grids increase the total profit. In order to evaluate the performance of the proposed method, its performance is executed on modified 33 bus distributed system as a micro grid. - Highlights: • Stochastic model is proposed for coordinated scheduling of renewable energy sources. • The effect of combined heat and power is considered. • Maximizing profits of micro grid is considered as objective function. • Considering the uncertainties of problem lead to profit increasing. • Optimal scheduling of renewable energy sources and thermal units increases profit.

  6. Evaluating the energy and CO2 emissions impacts of shifts in residential water heating in the United States

    Sanders, Kelly T.; Webber, Michael E.

    2015-01-01

    Water heating represented nearly 13% of 2010 residential energy consumption making it an important target for energy conservation efforts. The objective of this work is to identify spatially-resolved strategies for energy conservation, since little analysis has been done to identify how regional characteristics affect the energy consumed for water heating. We present a first-order thermodynamic analysis, utilizing ab initio calculations and regression methods, to quantify primary energy consumption and CO 2 emissions with regional specificity by considering by considering local electricity mixes, heat rates, solar radiation profiles, heating degrees days, and water heating unit sales for 27 regions of the US. Results suggest that shifting from electric towards natural gas or solar water heating offered primary energy and CO 2 emission reductions in most US regions, but these reductions varied considerably according to regional electricity mix and solar resources. We find that regions that would benefit most from technology transitions, are often least likely to switch due to limited economic incentives. Our results suggest that federal energy factor metrics, which ignore upstream losses in power generation, are insufficient in informing consumers about the energy performance of residential end use appliances. - Highlights: • US energy factor ratings for water heaters ignore upstream losses. • Switching from electric storage water heating reduces CO 2 emissions in most US regions. • Regions with greatest potential for CO 2 avoidance are least likely to shift technologies. • Benefits vary significantly according to climate and regional electricity fuel mix

  7. Economic feasibility of heat supply from nuclear power plants in the United States

    Roe, K.K.; Oliker, I.

    1987-01-01

    Nuclear energy is regarded as competitive for urban district heating applications. Hot water heat transoport systems of up to 50 miles are feasible for heat loads over 1500 MWt, and heat load density of over 130 MWt/mi 2 is most suitable for nuclear applications. An incremental approach and a nuclear plant design provision for future heat extraction are recommended. Nuclear district heating technology status is discussed, particularly turbine design. Results of a study for retrofitting a major existing nuclear power plant to cogeneration operation are presented. The study indicates that for transmission distances up to 20 miles it is economical to generate and transport between 600 and 1200 MWt of district heat (author)

  8. Monitoring and understanding changes in heat waves, cold waves, floods, and droughts in the United States: State of knowledge

    Peterson, Thomas C.; Heim, Richard R.; Hirsch, Robert M.; Kaiser, Dale P.; Brooks, Harold; Diffenbaugh, Noah S.; Dole, Randall M.; Giovannettone, Jason P.; Guirguis, Kristen; Karl, Thomas R.; Katz, Richard W.; Kunkel, Kenneth E.; Lettenmaier, Dennis P.; McCabe, Gregory J.; Paciorek, Christopher J.; Ryberg, Karen R.; K Wolter, BS Silva; Schubert, Siegfried; Silva, Viviane B. S.; Stewart, Brooke C.; Vecchia, Aldo V.; Villarini, Gabriele; Vose, Russell S.; Walsh, John; Wehner, Michael; Wolock, David; Wolter, Klaus; Woodhouse, Connie A.; Wuebbles, Donald

    2013-01-01

    Weather and climate extremes have been varying and changing on many different time scales. In recent decades, heat waves have generally become more frequent across the United States, while cold waves have been decreasing. While this is in keeping with expectations in a warming climate, it turns out that decadal variations in the number of U.S. heat and cold waves do not correlate well with the observed U.S. warming during the last century. Annual peak flow data reveal that river flooding trends on the century scale do not show uniform changes across the country. While flood magnitudes in the Southwest have been decreasing, flood magnitudes in the Northeast and north-central United States have been increasing. Confounding the analysis of trends in river flooding is multiyear and even multidecadal variability likely caused by both large-scale atmospheric circulation changes and basin-scale “memory” in the form of soil moisture. Droughts also have long-term trends as well as multiyear and decadal variability. Instrumental data indicate that the Dust Bowl of the 1930s and the drought in the 1950s were the most significant twentieth-century droughts in the United States, while tree ring data indicate that the megadroughts over the twelfth century exceeded anything in the twentieth century in both spatial extent and duration. The state of knowledge of the factors that cause heat waves, cold waves, floods, and drought to change is fairly good with heat waves being the best understood.

  9. Study of fuel cell powerplant with heat recovery

    King, J. M.; Grasso, A. P.; Clausi, J. V.

    1975-01-01

    It was shown that heat can be recovered from fuel cell power plants by replacing the air-cooled heat exchangers in present designs with units which transfer the heat to the integrated utility system. Energy availability for a 40-kW power plant was studied and showed that the total usable energy at rated power represents 84 percent of the fuel lower heating value. The effects of design variables on heat availability proved to be small. Design requirements were established for the heat recovery heat exchangers, including measurement of the characteristics of two candidate fuel cell coolants after exposure to fuel cell operating conditions. A heat exchanger test program was defined to assess fouling and other characteristics of fuel cell heat exchangers needed to confirm heat exchanger designs for heat recovery.

  10. Heat illness and death among workers - United States, 2012-2013.

    Arbury, Sheila; Jacklitsch, Brenda; Farquah, Opeyemi; Hodgson, Michael; Lamson, Glenn; Martin, Heather; Profitt, Audrey

    2014-08-08

    Exposure to heat and hot environments puts workers at risk for heat stress, which can result in heat illnesses and death. This report describes findings from a review of 2012‒2013 Occupational Safety and Health Administration (OSHA) federal enforcement cases (i.e., inspections) resulting in citations under paragraph 5(a)(1), the "general duty clause" of the Occupational Safety and Health Act of 1970. That clause requires that each employer "furnish to each of his employees employment and a place of employment which are free from recognized hazards that are causing or are likely to cause death or serious physical harm to his employees". Because OSHA has not issued a heat standard, it must use 5(a)(1) citations in cases of heat illness or death to enforce employers' obligations to provide a safe and healthy workplace. During the 2-year period reviewed, 20 cases of heat illness or death were cited for federal enforcement under paragraph 5(a)(1) among 18 private employers and two federal agencies. In 13 cases, a worker died from heat exposure, and in seven cases, two or more employees experienced symptoms of heat illness. Most of the affected employees worked outdoors, and all performed heavy or moderate work, as defined by the American Conference of Governmental Industrial Hygienists. Nine of the deaths occurred in the first 3 days of working on the job, four of them occurring on the worker's first day. Heat illness prevention programs at these workplaces were found to be incomplete or absent, and no provision was made for the acclimatization of new workers. Acclimatization is the result of beneficial physiologic adaptations (e.g., increased sweating efficiency and stabilization of circulation) that occur after gradually increased exposure to heat or a hot environment. Whenever a potential exists for workers to be exposed to heat or hot environments, employers should implement heat illness prevention programs (including acclimatization requirements) at their

  11. Quantity, Quality, and Availability of Waste Heat from United States Thermal Power Generation.

    Gingerich, Daniel B; Mauter, Meagan S

    2015-07-21

    Secondary application of unconverted heat produced during electric power generation has the potential to improve the life-cycle fuel efficiency of the electric power industry and the sectors it serves. This work quantifies the residual heat (also known as waste heat) generated by U.S. thermal power plants and assesses the intermittency and transport issues that must be considered when planning to utilize this heat. Combining Energy Information Administration plant-level data with literature-reported process efficiency data, we develop estimates of the unconverted heat flux from individual U.S. thermal power plants in 2012. Together these power plants discharged an estimated 18.9 billion GJ(th) of residual heat in 2012, 4% of which was discharged at temperatures greater than 90 °C. We also characterize the temperature, spatial distribution, and temporal availability of this residual heat at the plant level and model the implications for the technical and economic feasibility of its end use. Increased implementation of flue gas desulfurization technologies at coal-fired facilities and the higher quality heat generated in the exhaust of natural gas fuel cycles are expected to increase the availability of residual heat generated by 10.6% in 2040.

  12. Heat balance calculation and feasibility analysis for initial startup of Fuqing nuclear turbine unit with non-nuclear steam

    He Liu; Xiao Bo; Song Yumeng

    2014-01-01

    Non-nuclear steam run up compared with nuclear steam run up, can verify the design, manufacture, installation quality of the unit, at the same time shorten the follow-up duration of the entire group ready to start debugging time. In this paper, starting from the first law of thermodynamics, Analyzed Heat balance Calculation and Feasibility analysis for Initial startup of Fuqing nuclear Turbine unit with Non-nuclear steam, By the above calculation, to the system requirements and device status on the basis of technical specifications, confirmed the feasibility of Non-nuclear steam running up in theory. After the implementation of the Non-nuclear turn of Fuqing unit, confirmed the results fit with the actual process. In summary, the Initial startup of Fuqing turbine unit with Non-nuclear steam is feasible. (authors)

  13. A novel algorithm for demand-control of a single-room ventilation unit with a rotary heat exchanger

    Smith, Kevin Michael; Jansen, Anders Lund; Svendsen, Svend

    in the indoor environment. Based on these values, a demand-control algorithm varies fan speeds to change airflow rates and varies the rotational speed of the heat exchanger to modulate heat and moisture recovery. The algorithm varies airflow rates to provide free cooling and limit CO2 concentrations and varies...... moisture recovery by varying the rotational speed and then safely unbalances airflows in a worst-case scenario. In the algorithm, frost protection and minimum supply temperature take the highest priority and override other controls. This paper documents the proposed demand control algorithm and analyses...... its impacts on compliance of building regulations in Denmark. The paper presents an algorithm that manufacturers can program into their controls. The commercially available single-room ventilation unit with a rotary heat exchanger uses this algorithm coded in the C language. Future work will document...

  14. Comparison of Advanced Residential Water Heating Technologies in the United States

    Maguire, J.; Fang, X.; Wilson, E.

    2013-05-01

    Gas storage, gas tankless, condensing, electric storage, heat pump, and solar water heaters were simulated in several different climates across the US installed in both conditioned and unconditioned space and subjected to several different draw profiles. While many preexisting models were used, new models of condensing and heat pump water heaters were created specifically for this work.

  15. Experimental analysis of an air-to-air heat recovery unit for balanced ventilation systems in residential buildings

    Fernandez-Seara, Jose; Diz, Ruben; Uhia, Francisco J.; Dopazo, Alberto; Ferro, Jose M.

    2011-01-01

    This paper deals with the experimental analysis of an air-to-air heat recovery unit equipped with a sensible polymer plate heat exchanger (PHE) for balanced ventilation systems in residential buildings. The PHE is arranged in parallel triangular ducts. An experimental facility was designed to reproduce the typical outdoor and exhaust air conditions with regard to temperature and humidity. The unit was tested under balanced operation conditions, as commonly used in practice. A set of tests was conducted under the reference operating conditions to evaluate the PHE performance. Afterwards, an experimental parametric analysis was conducted to investigate the influence of changing the operating conditions on the PHE performance. Experiments were carried out varying the inlet fresh air temperature, the exhaust air relative humidity and the air flow rate. The experimental results are shown and discussed in this paper.

  16. Recovering method for high level radioactive material

    Fukui, Toshiki

    1998-01-01

    Offgas filters such as of nuclear fuel reprocessing facilities and waste control facilities are burnt, and the burnt ash is melted by heating, and then the molten ashes are brought into contact with a molten metal having a low boiling point to transfer the high level radioactive materials in the molten ash to the molten metal. Then, only the molten metal is evaporated and solidified by drying, and residual high level radioactive materials are recovered. According to this method, the high level radioactive materials in the molten ashes are transferred to the molten metal and separated by the difference of the distribution rate of the molten ash and the molten metal. Subsequently, the molten metal to which the high level radioactive materials are transferred is heated to a temperature higher than the boiling point so that only the molten metal is evaporated and dried to be removed, and residual high level radioactive materials are recovered easily. On the other hand, the molten ash from which the high level radioactive material is removed can be discarded as ordinary industrial wastes as they are. (T.M.)

  17. Investigation of the Dynamic Melting Process in a Thermal Energy Storage Unit Using a Helical Coil Heat Exchanger

    Xun Yang

    2017-08-01

    Full Text Available In this study, the dynamic melting process of the phase change material (PCM in a vertical cylindrical tube-in-tank thermal energy storage (TES unit was investigated through numerical simulations and experimental measurements. To ensure good heat exchange performance, a concentric helical coil was inserted into the TES unit to pipe the heat transfer fluid (HTF. A numerical model using the computational fluid dynamics (CFD approach was developed based on the enthalpy-porosity method to simulate the unsteady melting process including temperature and liquid fraction variations. Temperature measurements using evenly spaced thermocouples were conducted, and the temperature variation at three locations inside the TES unit was recorded. The effects of the HTF inlet parameters were investigated by parametric studies with different temperatures and flow rate values. Reasonably good agreement was achieved between the numerical prediction and the temperature measurement, which confirmed the numerical simulation accuracy. The numerical results showed the significance of buoyancy effect for the dynamic melting process. The system TES performance was very sensitive to the HTF inlet temperature. By contrast, no apparent influences can be found when changing the HTF flow rates. This study provides a comprehensive solution to investigate the heat exchange process of the TES system using PCM.

  18. Micro-cogeneration units based on Stirling engine for heating and their real operation

    Čierny, Jaroslav; Patsch, Marek

    2014-08-01

    This article was deal with micro-cogeneration units based on Stirling engine. We watched problematic of real working Stirling engine. The article also contain hookup of unit constructed at University of Zilina.

  19. A variant of the dynamic programming algorithm for unit commitment of combined heat and power systems

    Rong, Aiying; Hakonen, Henri; Lahdelma, Risto

    2008-01-01

    introduce in this paper the DP-RSC1 algorithm, which is a variant of the dynamic programming (DP) algorithm based on linear relaxation of the ON/OFF states of the units and sequential commitment of units one by one. The time complexity of DP-RSC1 is proportional to the number of generating units...

  20. Evaluation of European District Heating Systems for Application to Army Installations in the United States

    2006-07-01

    of the conurbation, the effectiveness of the investments as well as the plant’s management and the owner’s return requirements ( Energia 2004...37 p. Design Manual of ThermoNet Systems. 32 p. (In Finnish). ECONET Manual. 2005. Fläktwoods. Energia 2004. Energy year 2004. “District Heating...Pulliainen, K. 2005. Helsingin Energia . Oral source. Seppänen, O. 1995. ISBN 951-97233-1-5. Heating of Buildings. Publisher Suomen LVI- yhdistyken

  1. Complementary-relationship-based 30 year normals (1981-2010) of monthly latent heat fluxes across the contiguous United States

    Szilagyi, Jozsef

    2015-11-01

    Thirty year normal (1981-2010) monthly latent heat fluxes (ET) over the conterminous United States were estimated by a modified Advection-Aridity model from North American Regional Reanalysis (NARR) radiation and wind as well as Parameter-Elevation Regressions on Independent Slopes Model (PRISM) air and dew-point temperature data. Mean annual ET values were calibrated with PRISM precipitation (P) and validated against United States Geological Survey runoff (Q) data. At the six-digit Hydrologic Unit Code level (sample size of 334) the estimated 30 year normal runoff (P - ET) had a bias of 18 mm yr-1, a root-mean-square error of 96 mm yr-1, and a linear correlation coefficient value of 0.95, making the estimates on par with the latest Land Surface Model results but without the need for soil and vegetation information or any soil moisture budgeting.

  2. Process of recovering bituminous materials

    1920-08-22

    A modification of the process covered by German Patent 389,393 for recovering bituminous materials from oil shale by extraction is disclosed consisting, in place of or besides wood spirit oil, of acetone oil, suitably of boiling point 80 to 130/sup 0/C, being used as the extraction medium.

  3. Analysis of loss of decay heat removal sequences at Browns Ferry Unit One: Chapter 17

    Harrington, R.M.

    1983-01-01

    This paper summarizes the Oak Ridge National Laboratory (ORNL) report ''Loss of DHR Sequences at Browns Ferry Unit One - Accident Sequence Analysis'' (NUREG/CR-2973). The Loss of DHR investigation is the third in a series of accident studies concerning the BWR 4 - MK I containment plant design. These studies, sponsored by the Nuclear Regulatory Commission Severe Accident Sequence Analysis (SASA) program, have been conducted at ORNL with the full cooperation of the Tennessee Valley Authority (TVA), using Unit One of the Browns Ferry Nuclear Plant as the model design. Each unit of this three-unit plant has a maximum authorized power of 3293 MW(t) or 1067 net MW(e). The primary containments are of the Mark I pressure suppression pool type and the three units share a secondary containment of the controlled leakage, elevated release design. Each unit occupies a separate reactor building located in one structure underneath the common refueling floor

  4. Differences in Heat-Related Mortality by Citizenship Status: United States, 2005-2014.

    Taylor, Ethel V; Vaidyanathan, Ambarish; Flanders, W Dana; Murphy, Matthew; Spencer, Merianne; Noe, Rebecca S

    2018-04-01

    To determine whether non-US citizens have a higher mortality risk of heat-related deaths than do US citizens. We used place of residence reported in mortality data from the National Vital Statistics System from 2005 to 2014 as a proxy for citizenship to examine differences in heat-related deaths between non-US and US citizens. Estimates from the US Census Bureau American Community Survey of self-reported citizenship status and place of birth provided the numbers for the study population. We calculated the standardized mortality ratio and relative risk for heat-related deaths between non-US and US citizens nationally. Heat-related deaths accounted for 2.23% (n = 999) of deaths among non-US citizens and 0.02% (n = 4196) of deaths among US citizens. The age-adjusted standardized mortality ratio for non-US citizens compared with US citizens was 3.4 (95% confidence ratio [CI] = 3.2, 3.6). This risk was higher for Hispanic non-US citizens (risk ratio [RR] = 3.6; 95% CI = 3.2, 3.9) and non-US citizens aged 18 to 24 years (RR = 20.6; 95% CI = 16.5, 25.7). We found an increased mortality risk among non-US citizens compared with US citizens for heat-related deaths, especially those younger and of Hispanic ethnicity.

  5. The epidemiology of occupational heat exposure in the United States: a review of the literature and assessment of research needs in a changing climate

    Gubernot, Diane M.; Anderson, G. Brooke; Hunting, Katherine L.

    2014-10-01

    In recent years, the United States has experienced record-breaking summer heat. Climate change models forecast increasing US temperatures and more frequent heat wave events in the coming years. Exposure to environmental heat is a significant, but overlooked, workplace hazard that has not been well-characterized or studied. The working population is diverse; job function, age, fitness level, and risk factors to heat-related illnesses vary. Yet few studies have examined or characterized the incidence of occupational heat-related morbidity and mortality. There are no federal regulatory standards to protect workers from environmental heat exposure. With climate change as a driver for adaptation and prevention of heat disorders, crafting policy to characterize and prevent occupational heat stress for both indoor and outdoor workers is increasingly sensible, practical, and imperative.

  6. Nonazeotropic Heat Pump

    Ealker, David H.; Deming, Glenn

    1991-01-01

    Heat pump collects heat from water circulating in heat-rejection loop, raises temperature of collected heat, and transfers collected heat to water in separate pipe. Includes sealed motor/compressor with cooling coils, evaporator, and condenser, all mounted in outer housing. Gradients of temperature in evaporator and condenser increase heat-transfer efficiency of vapor-compression cycle. Intended to recover relatively-low-temperature waste heat and use it to make hot water.

  7. Development of a method for calculating steady-state equipment sensible heat ratio of direct expansion air conditioning units

    Xia Liang; Chan, M.Y.; Deng Shiming

    2008-01-01

    A complete set of calculation method for steady-state equipment sensible heat ratio (SHR) for a direct expansion (DX) cooling coil has been developed and reported. The method was based on the fundamentals of energy conservation and heat and mass transfer taking place in the DX cooling coil, and was experimentally validated using an experimental DX A/C rig. With the method developed, the effect of refrigerant evaporating temperature at fixed inlet air conditions on equipment SHR has been theoretically analyzed. The validated method can be useful in further studying the inherent operating characteristics of a DX air conditioning (A/C) unit and in developing suitable control strategies for achieving higher energy efficiency and better indoor thermal environment

  8. Metallurgical investigation of cracking of the isolation valve downstream piping of regenerative heat exchanger at beaver valley unit 1 station

    Rao, G.V.

    1998-01-01

    A metallurgical investigation was conducted to establish the mechanism and cause of cracking in the regenerative heat exchanger piping at Beaver Valley Unit 1 PWR station in the USA. The investigation, which was centered on an eight inch long pipe section containing the cracking included surface examinations, metallographic and fractographic examinations, and chemistry evaluations. The results of the examinations showed that there were two types of pipe degradation mechanisms that affected the type 304 stainless schedule 40 piping. These consisted of localized corrosive attack on the OD surface due to the presence of chlorides, sulphates and phosphates, and transgranular stress corrosion cracking in the pipe wall due to the presence of chloride contaminants. The overall results of the investigation showed that the introduction of contaminants from external sources other than pipe insulation was the cause of heat exchanger pipe cracking. (author)

  9. Recovering valuable shale oils, etc

    Engler, C

    1922-09-26

    A process is described for the recovery of valuable shale oils or tars, characterized in that the oil shale is heated to about 300/sup 0/C or a temperature not exceeding this essentially and then is treated with a solvent with utilization of this heat.

  10. Economic and policy factors driving adoption of institutional woody biomass heating systems in the United States

    Jesse D. Young; Nathaniel M. Anderson; Helen T. Naughton; Katrina Mullan

    2018-01-01

    Abundant stocks of woody biomass that are associated with active forest management can be used as fuel for bioenergy in many applications. Though factors driving large-scale biomass use in industrial settings have been studied extensively, small-scale biomass combustion systems commonly used by institutions for heating have received less attention. A zero inflated...

  11. Treating effluents; recovering coal, etc

    Jones, F B; Bury, E

    1920-02-18

    Liquor obtained by scrubbing coal gas with sea-water or fresh water, and containing or having added to it finely-divided carbonaceous material in suspension, is subjected to a froth-flotation process to recover the carbonaceous matter and organic materials in the froth, and render the remaining liquor innocuous. Liquor obtained by scrubbing distillation gases, such as coal gas, may be used as a frothing-agent in a froth flotation process for the recovery of carbonaceous substances such as coal from materials containing them, thereby producing a froth containing the coal, etc., and also the organic materials from the liquor. In some cases the effluent may be diluted with sea-water, and, in recovering carbonaceous shales, there may be added to the liquor a small proportion of paraffin oil.

  12. Parameter effect of a phase change thermal energy storage unit with one shell and one finned tube on its energy efficiency ratio and heat storage rate

    Wang, Wei-Wei; Wang, Liang-Bi; He, Ya-Ling

    2016-01-01

    Highlights: • The parameter effect on the performance of PCTES unit using fins is reported. • The configurations of PCTES unit using fins in optimum performance are suggested. • Two parameters to indicate the effects of PCM and tube material properties are found. • The working conditions of PCTES unit using fins in optimum performance are analyzed. - Abstract: The performance of a phase change thermal energy storage (PCTES) unit using circular finned tube is affected by many parameters. Thorough studies of the parameter effect on the performance of PCTES unit are strongly required in its optimum design process. Based on a reported energy efficiency ratio and a newly defined parameter named the heat storage rate, the parameter effect on the performance of PCTES unit using circular finned tube is numerically investigated. When the fin pitch is greater than 4 times of the inner radius of the tube, the fin height and the fin thickness have little effect on the energy efficiency ratio and the heat storage rate. When the fin pitch is small, the performance of PCTES unit becomes better using large fin height and width. The energy efficiency ratio and the heat storage rate are more sensitive to the outer tube diameter. The performance of PCTES unit using circular finned tube is best when water is used as the heat transfer fluid (HTF). When the fluid flow of HTF is in a laminar state, the energy efficiency ratio and the heat storage rate are larger than that in a turbulent state.

  13. Methods of recovering alkali metals

    Krumhansl, James L; Rigali, Mark J

    2014-03-04

    Approaches for alkali metal extraction, sequestration and recovery are described. For example, a method of recovering alkali metals includes providing a CST or CST-like (e.g., small pore zeolite) material. The alkali metal species is scavenged from the liquid mixture by the CST or CST-like material. The alkali metal species is extracted from the CST or CST-like material.

  14. Heat Transfer Reactor Experiment (HTRE)-3 Container Storage Unit Resource Conservation Recovery Act closure plan

    Spry, M.J.

    1992-11-01

    This document describes the closure of the HTRE-3 Container Storage Unit under the requirements of the Resource Conservation and Recovery Act. The unit's location, size, history, and current status are described. The document also summarizes the decontamination and decommissioning efforts performed in 1983 and provides an estimate of,waste residues remaining in the HTRE-3 assembly. A risk evaluation was performed that demonstrates that the residue does not pose a hazard to public health or the environment. Based on the risk evaluation, it is proposed that the HTRE-3 Container Storage Unit be closed in its present condition, without further decontamination or removal activities

  15. Fundamental research on the gravity assisted heat pipe thermal storage unit (GAHP-TSU) with porous phase change materials (PCMs) for medium temperature applications

    Hu, Bo-wen; Wang, Qian; Liu, Zhen-Hua

    2015-01-01

    Highlights: • A novel gravity-assisted heat pipe thermal storage unit (GAHP-TSU) is presented and tested. • Composite granular solid–liquid PCM is piled up as the porous medium layer in GAHP-TSU. • GAHP-TSU avoids the major obstacle of low thermal conductivity of the PCM. • GAHP-TSU enables the thermal storage unit with outstanding heat transfer performance. - Abstract: In this study, a novel gravity-assisted heat pipe type thermal storage unit (GAHP-TSU) has been presented for the potential application in solar air conditioning and refrigeration systems, in which composite granular solid–liquid PCMs compounded by RT100 and high-density polyethylene with phase change temperature of 100 °C are piled up as a porous PCMs medium layer. Water is used as heat transfer fluid in the GAHP-TSU. The heat transfer mechanism of heat storage/release in the GAHP-TSU is similar to that of the gravity-assisted heat pipe, which is superior to traditional direct-contact or indirect-contact thermal storage units. The properties of start-up, heat transfer characteristics on the stages of heat absorption and release of the GAHP-TSU are studied in detailed, including necessary calculations based on heat transfer theory. The results show that the whole system is almost isothermal at the temperature over 70 °C and the heat transfer properties are excellent both for heat absorption and release stages. The GAHP-TSU device with low thermal conductivity of the PCMs is promising in potential industry applications

  16. Recovering energy and materials from hazardous waste

    Anon.

    2003-12-01

    The tannery industry faces growing environmental concerns because of the high hazardous metal content of its process waste. The formation, during the tanning process, of the highly toxic hexavalent chromium precludes the use of conventional thermal incineration processes. Borge Tannery in Norway, which processes 600 cattle hides per day, has solved the problem by using new PyroArc technology. The PyroArc waste processing plant can treat all of the tannery's production wastes, transforming them into useful products such as fuel gas and re-usable metal. The fuel gas consists mainly of carbon monoxide, hydrogen and nitrogen, and has a calorific value of about 4 MJ/Nm{sub 3}. About 65-70% of the energy content of the source material (waste or biomass) is recovered in the gas, and this is used to produce steam and/or electricity in a gas engine with a capacity of 580 kW. A further 20-25% of the initial energy content is recovered as heat or low-pressure steam. The plant is designed to be self-sufficient in energy (1.5 MW) and to meet the tannery's maximum requirements for hot water and steam. (UK)

  17. Performance of double source boiler with coal-fired and solar power tower heat for supercritical power generating unit

    Zhang, Maolong; Du, Xiaoze; Pang, Liping; Xu, Chao; Yang, Lijun

    2016-01-01

    An approach of high-efficiency utilization of solar energy was proposed, by which the high concentrated heat received by the solar tower was integrated to the supercritical coal-fired boiler. Two schemes that solar energy was used to heat superheat steam or subcooled feed water were presented. The thermodynamic and heat transfer models were established. For a practical 660 MW supercritical power generating unit, the standard coal consumption of power generation could be decreased by more than 17 g/kWh by such double source boiler. The drawbacks of both schemes were found and then were amended by adding a flue gas bypass to the boiler. It also can be concluded that the maximum solar contribution of two schemes for the gross power generation are 6.11% and 4.90%, respectively. The solar power efficiency of the re-modified designs were demonstrated be superior to that of PS10. In terms of turbine efficiency, the comparisons with Solar Two plant having similar initial temperature found that the efficiency of Scheme I was 5.25% higher than that of Solar Two while the advantage of Scheme II was existing either. Additionally, in two schemes with flue bypass when the medium was extracted, the thermal efficiency of boiler could be improved as well. - Highlights: • High concentrated solar tower heat is integrated to the supercritical coal-fired boiler. • The double source boiler can use solar energy to heat superheat steam or subcooled feed water. • Power generating coal consumption can be reduced by more than 17 g/kWh by the double source boiler. • The solar contribution of double source boiler for the gross power generation can be as high as 6.11%.

  18. Cesarean Section: Recovering After Surgery

    Full Text Available ... unit (NICU) Birth defects & other health conditions Loss & grief Tools & Resources Frequently asked health questions Calculating your ... unit (NICU) Birth defects & other health conditions Loss & grief Tools & Resources Frequently asked health questions Calculating your ...

  19. Stochastic PSO-based heat and power dispatch under environmental constraints incorporating CHP and wind power units

    Piperagkas, G.S.; Anastasiadis, A.G.; Hatziargyriou, N.D. [National Technical University of Athens, School of Electrical and Computer Engineering, Electric Power Division, 9, Iroon Polytechneiou Str., GR-15773 Zografou, Athens (Greece)

    2011-01-15

    In this paper an extended stochastic multi-objective model for economic dispatch (ED) is proposed, that incorporates in the optimization process heat and power from CHP units and expected wind power. Stochastic restrictions for the CO{sub 2}, SO{sub 2} and NO{sub x} emissions are used as inequality constraints. The ED problem is solved using a multi-objective particle swarm optimization technique. The available wind power is estimated from a transformation of the wind speed considered as a random variable to wind power. Simulations are performed on the modified IEEE 30 bus network with 2 cogeneration units and actual wind data. Results concerning minimum cost and emissions reduction options are finally drawn. (author)

  20. Initial Investigation into the Potential of CSP Industrial Process Heat for the Southwest United States

    Kurup, Parthiv [National Renewable Energy Lab. (NREL), Golden, CO (United States); Turchi, Craig [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2015-11-01

    After significant interest in the 1970s, but relatively few deployments, the use of solar technologies for thermal applications, including enhanced oil recovery (EOR), desalination, and industrial process heat (IPH), is again receiving global interest. In particular, the European Union (EU) has been a leader in the use, development, deployment, and tracking of Solar Industrial Process Heat (SIPH) plants. The objective of this study is to ascertain U.S. market potential of IPH for concentrating collector technologies that have been developed and promoted through the U.S. Department of Energy's Concentrating Solar Power (CSP) Program. For this study, the solar-thermal collector technologies of interest are parabolic trough collectors (PTCs) and linear Fresnel (LF) systems.

  1. Heat Release Rate of an Open Kitchen Fire of Small Residential Units in Tall Buildings

    Chow, W.K.

    2014-01-01

    Many small units of area less than 30 m2 in residential buildings over 200 m tall are equipped with open kitchens in Asia, including Hong Kong. Fire safety provisions of these kitchens are determined by performance-based design (PBD). In most PBD projects, only the spread of smoke from the kitchen on fire to the outside was commonly studied. However, a fire load survey in Hong Kong indicated large quantities of combustibles are stored in residential units. Cooking oil was found to be ignited ...

  2. Break-Even Cost for Residential Solar Water Heating in the United States: Key Drivers and Sensitivities

    Cassard, H.; Denholm, P.; Ong, S.

    2011-02-01

    This paper examines the break-even cost for residential rooftop solar water heating (SWH) technology, defined as the point where the cost of the energy saved with a SWH system equals the cost of a conventional heating fuel purchased from the grid (either electricity or natural gas). We examine the break-even cost for the largest 1,000 electric and natural gas utilities serving residential customers in the United States as of 2008. Currently, the break-even cost of SWH in the United States varies by more than a factor of five for both electricity and natural gas, despite a much smaller variation in the amount of energy saved by the systems (a factor of approximately one and a half). The break-even price for natural gas is lower than that for electricity due to a lower fuel cost. We also consider the relationship between SWH price and solar fraction and examine the key drivers behind break-even costs. Overall, the key drivers of the break-even cost of SWH are a combination of fuel price, local incentives, and technical factors including the solar resource location, system size, and hot water draw.

  3. An improved unit decommitment algorithm for combined heat and power systems

    Rong, Aiying; Lahdelma, R.; Grunow, Martin

    2009-01-01

    can decommit (switch off) the least cost-efficient plants properly. The improved initial solution for the committed plants is generated by a heuristic procedure. The heuristic procedure utilizes both the Lagrangian relaxation principle that relaxes the system-wide (heat and power) demand constraints...... cases. The maximum improvement is 11.3% and the maximum degradation is only 0.04% (only two sub-cases out of 216 sub-cases) with an average improvement of 0.3-0.5%, for different planning horizons. Moreover, IUD is more efficient (1.1-3 times faster on average) than UD. (C) 2008 Elsevier B.V. All rights...

  4. Heat and Molecules. Seychelles Integrated Science. [Teacher and Pupil Booklets]. Unit 10.

    Brophy, M.; Fryars, M.

    Seychelles Integrated Science (SIS), a 3-year laboratory-based science program for students (ages 11-15) in upper primary grades 7, 8, and 9, was developed from an extensive evaluation and modification of previous P7-P9 materials. This P8 SIS unit deals with: (1) changes in temperature which make matter expand and contract (and how this affects…

  5. Study on a heat recovery system for the thermal power plant utilizing air cooling island

    Sun, Jian; Fu, Lin; Sun, Fangtian; Zhang, Shigang

    2014-01-01

    A new heat recovery system for CHP (combined heat and power) systems named HRU (heat recovery unit) is presented, which could recover the low grade heat of exhausted steam from the turbine at the thermal power plant directly. Heat recovery of exhausted steam is often accomplished by recovering the heat of cooling water in current systems. Therefore, two processes of heat transfer is needed at least. However, exhausted steam could be condensed in the evaporator of HRU directly, which reduce one process of heat transfer. A special evaporator is designed condense the exhausted steam directly. Simulated results are compared to experiments, which could include the calculation of heat transfer coefficients of different parts of HRU. It is found that about 25Mw of exhausted steam is recovered by this system. HRU could be promising for conventional CHP systems, which could increase the total energy efficiency obviously and enlarge the heating capacity of a built CHP system. - Highlights: • A new heat recovery system for thermal power plant is presented. • A mathematical model including heat transfer coefficients calculation is given. • This heat recovery system is experimented at a thermal power plant. • Performances of this system under different working conditions are simulated

  6. Upgraded RECOVER system - CASDAC system

    Yamamoto, Yoichi; Koyama, Kinji

    1992-03-01

    The CASDAC (Containment And Surveillance Data Authenticated Communication) system has been developed by JAERI for nuclear safeguards and physical protection of nuclear material. This system was designed and constructed as an upgraded RECOVER system, design concept of which was based on the original RECOVER system and also the TRANSEAVER system. Both of them were developed several years ago as a remote monitoring system for continual verification of security and safeguards status of nuclear material. The system consists of two subsystems, one of them is a Grand Command Center (GCC) subsystem and the other is a facility subsystem. Communication between the two subsystems is controlled through the international telephone line network. Therefore all communication data are encrypted to prevent access by an unauthorized person who may intend to make a falsification, or tapping. The facility subsystem has an appropriate measure that ensure data security and reliable operation under unattended mode of operator. The software of this system is designed so as to be easily used in other different types of computers. This report describes the outline of the CASDAC system and the results of its performance test. This work has been carried out in the framework of Japan Support Programme for Agency Safeguards (JASPAS) as a project, JA-1. (author)

  7. Simple equation for estimating actual evapotranspiration using heat units for wheat in arid regions

    M.A. Salama

    2015-07-01

    Application of treatment (B resulted in highly significant increase in yield production of Gemmeza10 and Misr2 as compared to treatment (A. Grain yield of different wheat varieties grown under treatment (B could be ranked in the following descending order: Misr2 > Gemmeza10 > Sids12. While under treatment (A it could be arranged in the following descending order: Misr2 > Sids12 > Gemmeza10. On the other hand, the overall means indicated non-significant difference between all wheat verities. The highest values of water and irrigation use efficiency as well as heat use efficiency were obtained with treatment (B. The equation used in the present study is available to estimate ETa under arid climate with drip irrigation system.

  8. Recovering uranium from phosphoric acid

    Anon.

    1979-01-01

    Wet-process phosphoric acid contains a significant amount of uranium. This uranium totals more than 1,500 tons/yr in current U.S. acid output--and projections put the uranium level at 8,000 tons/yr in the year 2000. Since the phosphoric acid is a major raw material for fertilizers, uranium finds its way into those products and is effectively lost as a resource, while adding to the amount of radioactive material that can contaminate the food chain. So, resource-conservation and environmental considerations both make recovery of the uranium from phosphoric acid desirable. This paper describes the newly developed process for recovering uranium from phosphoric acid by using solvent-extraction technique. After many extractants had been tested, the researchers eventually selected the combination of di (2-ethylhexyl) phosphoric acid (DEPA) and trioctylphosphine oxide (TOPO) as the most suitable. The flowscheme of the process is included

  9. Cesarean Section: Recovering After Surgery

    Full Text Available ... premature birth The newborn intensive care unit (NICU) Birth defects & other health conditions Loss & grief Tools & Resources Frequently asked health questions Calculating your due date Ovulation calendar Order bereavement materials News Moms Need Blog Stories & Media ...

  10. Cesarean Section: Recovering After Surgery

    Full Text Available ... for your baby Feeding your baby Family health & safety Complications & Loss Pregnancy complications Preterm labor & premature birth The newborn intensive care unit (NICU) Birth defects & other health conditions Loss & grief Tools & Resources Frequently asked health questions ...

  11. Uranium material removing and recovering device

    Takita, Shin-ichi.

    1997-01-01

    A uranium material removing and recovering device for use in removing surplus uranium heavy metal (UO 2 ) generated in a uranium handling facility comprises a uranium material removing device and a uranium material recovering device. The uranium material removing device comprises an adsorbing portion filled with a uranium adsorbent, a control portion for controlling the uranium adsorbent of the uranium adsorbing portion by a controlling agent, a uranium adsorbing device connected thereto and a jetting device for jetting the adsorbing liquid to equipments deposited with uranium. The recovering device comprises a recovering apparatus for recovering uranium materials deposited with the adsorbent liquid removed by the jetting device and a recovering tank for storing the recovered uranium materials. The device of the present invention can remove surplus uranium simply and safely, mitigate body's load upon removing and recovering operations, facilitate the processing for the exchange of the adsorbent and reduces the radioactive wastes. (T.M.)

  12. Regenerator heat exchanger – calculation of heat recovery efficiency and pressure loss

    Pomianowski, Michal Zbigniew; Heiselberg, Per Kvols

    Performance of heat exchangers is determined based on two main parameters: efficiency to exchange / recover heat and pressure loss due to friction between fluid and exchanger surfaces. These two parameters are contradicting each other which mean that the higher is efficiency the higher becomes...... pressure loss. The aim of the optimized design of heat exchanger is to reach the highest or the required heat efficiency and at the same time to keep pressure losses as low as possible keeping total exchanger size within acceptable size. In this report is presented analytical calculation method...... to calculate efficiency and pressure loss in the regenerator heat exchanger with a fixed matrix that will be used in the decentralized ventilation unit combined in the roof window. Moreover, this study presents sensitivity study of regenerator heat exchanger performance, taking into account, such parameters as...

  13. Large-scale heat pumps in sustainable energy systems: System and project perspectives

    Blarke Morten B.

    2007-01-01

    Full Text Available This paper shows that in support of its ability to improve the overall economic cost-effectiveness and flexibility of the Danish energy system, the financially feasible integration of large-scale heat pumps (HP with existing combined heat and power (CHP plants, is critically sensitive to the operational mode of the HP vis-à-vis the operational coefficient of performance, mainly given by the temperature level of the heat source. When using ground source for low-temperature heat source, heat production costs increases by about 10%, while partial use of condensed flue gasses for low-temperature heat source results in an 8% cost reduction. Furthermore, the analysis shows that when a large-scale HP is integrated with an existing CHP plant, the projected spot market situation in The Nordic Power Exchange (Nord Pool towards 2025, which reflects a growing share of wind power and heat-supply constrained power generation electricity, further reduces the operational hours of the CHP unit over time, while increasing the operational hours of the HP unit. In result, an HP unit at half the heat production capacity as the CHP unit in combination with a heat-only boiler represents as a possibly financially feasible alternative to CHP operation, rather than a supplement to CHP unit operation. While such revised operational strategy would have impacts on policies to promote co-generation, these results indicate that the integration of large-scale HP may jeopardize efforts to promote co-generation. Policy instruments should be designed to promote the integration of HP with lower than half of the heating capacity of the CHP unit. Also it is found, that CHP-HP plant designs should allow for the utilization of heat recovered from the CHP unit’s flue gasses for both concurrent (CHP unit and HP unit and independent operation (HP unit only. For independent operation, the recovered heat is required to be stored. .

  14. Environmental compatibility of biogas operated combined heat and power units in practice; Umweltvertraeglichkeit biogasbetriebener Blockheizkraftwerke in der Praxis

    Aschmann, V.; Kissel, R.; Gronauer, A. [Bayerische Landesanstalt fuer Landwirtschaft (LfL), Freising (Germany). Inst. fuer Landtechnik und Tierhaltung

    2008-07-01

    Since the amendment of the Renewable Energies Act the number of start-ups of new biogas plants increased substantially. For a sustainable and environmentally friendly power production the output of pollutants is to be minimized. Under this aspect, the authors of the contribution under consideration report on investigations at six biogas operated combined heat and power units on agricultural biogas facilities. The limit values of exhaust gas relative to nitrogen oxides cannot be kept during operation at full load. A falling below of the limit value can be achieved only under acceptance of losses of the efficiency and simultaneous increase of the portion of unburned hydrocarbons in the exhaust gas. There is a direct connection between the reduction of the concentration of nitrogen oxides and the output quantity of hydrocarbons.

  15. Bone heat generated using conventional implant drills versus piezosurgery unit during apical cortical plate perforation.

    Lajolo, Carlo; Valente, Nicola Alberto; Romandini, William Giuseppe; Petruzzi, Massimo; Verdugo, Fernando; D'Addona, Antonio

    2018-03-09

    The apical portion of the implant osteotomy receives less irrigation and cooling during surgical preparation. High bone temperatures, above the critical 10°C threshold, may impair osseointegration, particularly, around dense cortical bone. The aim of this study is to evaluate the apical cortical plate temperature increase with two different devices and pressure loads in a porcine rib ex-vivo model. Twenty-four implant sites were prepared on porcine ribs divided into 4 groups of 6 samples each according to the device used (conventional drill system or piezosurgery) and pressure load applied (1000 g or 1500 g). A rubber dam was used to isolate the apical cortical plate from the cooling effect of irrigation. Temperature variation measurements were taken using an infrared thermometer. The piezosurgery unit was 2 times more likely to increase the osteotomy temperature by 10.0°C (OR = 2; 95% CI = 1.136-3.522; p piezosurgery-1000 g) and 8.17°C (SD = 6.12) for group 4 (piezosurgery-1,500 g). The piezosurgery site preparation caused significantly higher temperature increase than conventional drills (p piezosurgery unit is a potential risk during implant site preparation. The piezosurgical device reached significantly higher temperatures than conventional drilling at the apical cortical portion of the osteotomy. The temperature increase is often higher than the critical 10°C threshold. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  16. Optimal stochastic coordinated scheduling of proton exchange membrane fuel cell-combined heat and power, wind and photovoltaic units in micro grids considering hydrogen storage

    Bornapour, Mosayeb; Hooshmand, Rahmat-Allah; Khodabakhshian, Amin; Parastegari, Moein

    2017-01-01

    Highlights: •Stochastic model is proposed for coordinated scheduling of renewable energy sources. •The effect of combined heat and power is considered. •Hydrogen storage is considered for fuel cells. •Maximizing profits of micro grid is considered as objective function. •Considering the uncertainties of problem lead to profit increasing. -- Abstract: Nowadays, renewable energy sources and combined heat and power units are extremely used in micro grids, so it is necessary to schedule these units to improve the performance of the system. In this regard, a stochastic model is proposed in this paper to schedule proton exchange membrane fuel cell-combined heat and power, wind turbines, and photovoltaic units coordinately in a micro grid while considering hydrogen storage. Hydrogen storage strategy is considered for the operation of proton exchange membrane fuel cell-combined heat and power units. To consider stochastic generation of renewable energy source units in this paper, a scenario-based method is used. In this method, the uncertainties of electrical market price, the wind speed, and solar irradiance are considered. This stochastic scheduling problem is a mixed integer- nonlinear programming which considers the proposed objective function and variables of coordinated scheduling of PEMFC-CHP, wind turbines and photovoltaic units. It also considers hydrogen storage strategy and converts it to a mixed integer nonlinear problem. In this study a modified firefly algorithm is used to solve the problem. This method is examined on modified 33-bus distributed network as a MG for its performance.

  17. Water from abandoned mines as a heat source: practical experiences of open- and closed-loop strategies, United Kingdom

    Banks, D; Athresh, A; Al-Habaibeh, A; Burnside, N

    2017-01-01

    Pilot heat pump systems have been installed at two former collieries in Yorkshire/Derbyshire, England, to extract heat from mine water. The installations represent three fundamental configurations of heat exchanger. At Caphouse Colliery, mine water is pumped through a heat exchanger coupled to a heat pump and then discharged to waste (an open-loop heat exchange system). The system performs with high thermal efficiency, but the drawbacks are: (1) it can only be operated when mine water is bein...

  18. Combined heat and power unit using renewable raw materials. A cogeneration power plant with wood chips and pellets; BHKW auf Basis nachwachsender Rohstoffe. KWK mit Holzhackschnitzeln und Pellets

    Lennartz, Marc Wilhelm

    2013-07-15

    The combined heat and power units of the next generation operate with renewable resources. The plants working with wood chips or pellets now are ready for mass production. So, farmers and foresters, trade and municipalities may pile in the decentralized, energetic self-sufficiency. Two companies have developed procedures with which combined heat and power plants based can be operated on wood chips or pellets.

  19. Process for recovering oil from shale and other bituminous materials

    1918-08-23

    A process for recovering oil from shale and other bituminous minerals in rotary retorts heated from outside and flushed with water vapor or other oxygen-free gases is characterized by the fact that all kinds of minerals are carbonized, and that during the carbonization process the temperature of the superheated steam or gases is about 50/sup 0/ C higher than the temperature of the carbonized mineral.

  20. Analysis of the use of waste heat obtained from coal-fired units in Organic Rankine Cycles and for brown coal drying

    Łukowicz, Henryk; Kochaniewicz, Andrzej

    2012-01-01

    The ever-increasing restrictions on greenhouse gas emissions have created a need for new energy technologies. One way to meet these new requirements is to optimise the efficiency of power units. This paper presents two energy technologies that, if used, will increase the efficiency of electricity generation. One of the most effective ways to improve the efficiency of brown coal-fired units is by drying the coal that is fed into the boiler. Here, we describe a technology that uses the waste heat obtained from exhaust gases. This paper also presents an analysis of the feasibility of and potential for using waste heat obtained from exhaust gases to feed Organic Rankine Cycles (ORCs). Several low-temperature working fluids were considered, which were selected based on properties that were best suited for these types of cycles. The impact of these working fluids on the efficiency and capacity of the ORC was also examined. The calculations for ORCs fed with waste heat obtained from exhaust gases from hard coal- and brown coal-fired boilers were compared. -- Highlights: ► We describe a technology that uses the waste heat obtained from exhaust gases. ► The impact of using different working fluids with a low boiling point is examined. ► We describe integrating the ORC with the power unit. ► The use of waste heat from boiler exhaust gases to dry brown coal is proposed. ► We demonstrate a possible increase in power unit efficiency.

  1. A study of the reverse cycle defrosting performance on a multi-circuit outdoor coil unit in an air source heat pump – Part I: Experiments

    Qu, Minglu; Xia, Liang; Deng, Shiming; Jiang, Yiqiang

    2012-01-01

    Highlights: ► We experimental study the defrosting performance on a multi-circuit outdoor coil unit in an ASHP unit. ► We find that defrosting is quicker on the airside of upper circuits than that on the lower circuits. ► We discuss the effects of downwards flowing of the melted frost along the outdoor coil surface on defrosting performance. -- Abstract: When an air source heat pump (ASHP) unit operates in heating mode, frost can be accumulated on the surface of its finned outdoor coil which normally has multiple parallel circuits on its refrigerant side for minimized refrigerant pressure loss and enhanced heat transfer efficiency. On its airside, however, there is usually no segmentation corresponding to the number of refrigerant circuit. Frosting deteriorates the operation and energy efficiency of the ASHP unit and periodic defrosting becomes necessary. Currently the most widely used standard defrosting method for ASHPs is reverse cycle defrost. This paper, the first part of a two-part series, reports on the experimental part of a study of the reverse cycle defrosting performance on a multi-circuit outdoor coil unit in an experimental 6.5 kW heating capacity residential ASHP unit. Firstly the experimental ASHP unit is described and experimental procedures detailed. Secondly, the experimental results are reported. This is followed by the discussion on the effects of downwards flowing of the melted frost along a multi-circuit outdoor coil surface on defrosting performance. Finally, the evaluation of the defrosting efficiency for the experimental ASHP unit is provided. In the second part of the series, a modeling analysis on the effects of downwards flowing of the melted frost along the multi-circuit outdoor coil surface on defrosting performance of the experimental ASHP unit will be presented.

  2. Cesarean Section: Recovering After Surgery

    Full Text Available ... intensive care unit (NICU) Birth defects & other health conditions Loss & grief Tools & ... Dimes fights for the health of all moms and babies. We're advocating for policies to protect them. We're working to radically improve the health care they receive. ...

  3. Heat Maps of Hypertension, Diabetes Mellitus, and Smoking in the Continental United States.

    Loop, Matthew Shane; Howard, George; de Los Campos, Gustavo; Al-Hamdan, Mohammad Z; Safford, Monika M; Levitan, Emily B; McClure, Leslie A

    2017-01-01

    Geographic variations in cardiovascular mortality are substantial, but descriptions of geographic variations in major cardiovascular risk factors have relied on data aggregated to counties. Herein, we provide the first description of geographic variation in the prevalence of hypertension, diabetes mellitus, and smoking within and across US counties. We conducted a cross-sectional analysis of baseline risk factor measurements and latitude/longitude of participant residence collected from 2003 to 2007 in the REGARDS study (Reasons for Geographic and Racial Differences in Stroke). Of the 30 239 participants, all risk factor measurements and location data were available for 28 887 (96%). The mean (±SD) age of these participants was 64.8(±9.4) years; 41% were black; 55% were female; 59% were hypertensive; 22% were diabetic; and 15% were current smokers. In logistic regression models stratified by race, the median(range) predicted prevalence of the risk factors were as follows: for hypertension, 49% (45%-58%) among whites and 72% (68%-78%) among blacks; for diabetes mellitus, 14% (10%-20%) among whites and 31% (28%-41%) among blacks; and for current smoking, 12% (7%-16%) among whites and 18% (11%-22%) among blacks. Hypertension was most prevalent in the central Southeast among whites, but in the west Southeast among blacks. Diabetes mellitus was most prevalent in the west and central Southeast among whites but in south Florida among blacks. Current smoking was most prevalent in the west Southeast and Midwest among whites and in the north among blacks. Geographic disparities in prevalent hypertension, diabetes mellitus, and smoking exist within states and within counties in the continental United States, and the patterns differ by race. © 2017 American Heart Association, Inc.

  4. Heat and Humidity in the City: Neighborhood Heat Index Variability in a Mid-Sized City in the Southeastern United States.

    Hass, Alisa L; Ellis, Kelsey N; Reyes Mason, Lisa; Hathaway, Jon M; Howe, David A

    2016-01-11

    Daily weather conditions for an entire city are usually represented by a single weather station, often located at a nearby airport. This resolution of atmospheric data fails to recognize the microscale climatic variability associated with land use decisions across and within urban neighborhoods. This study uses heat index, a measure of the combined effects of temperature and humidity, to assess the variability of heat exposure from ten weather stations across four urban neighborhoods and two control locations (downtown and in a nearby nature center) in Knoxville, Tennessee, USA. Results suggest that trees may negate a portion of excess urban heat, but are also associated with greater humidity. As a result, the heat index of locations with more trees is significantly higher than downtown and areas with fewer trees. Trees may also reduce heat stress by shading individuals from incoming radiation, though this is not considered in this study. Greater amounts of impervious surfaces correspond with reduced evapotranspiration and greater runoff, in terms of overall mass balance, leading to a higher temperature, but lower relative humidity. Heat index and relative humidity were found to significantly vary between locations with different tree cover and neighborhood characteristics for the full study time period as well as for the top 10% of heat index days. This work demonstrates the need for high-resolution climate data and the use of additional measures beyond temperature to understand urban neighborhood exposure to extreme heat, and expresses the importance of considering vulnerability differences among residents when analyzing neighborhood-scale impacts.

  5. Investigation and optimization of the depth of flue gas heat recovery in surface heat exchangers

    Bespalov, V. V.; Bespalov, V. I.; Melnikov, D. V.

    2017-09-01

    Economic issues associated with designing deep flue gas heat recovery units for natural gas-fired boilers are examined. The governing parameter affecting the performance and cost of surface-type condensing heat recovery heat exchangers is the heat transfer surface area. When firing natural gas, the heat recovery depth depends on the flue gas temperature at the condenser outlet and determines the amount of condensed water vapor. The effect of the outlet flue gas temperature in a heat recovery heat exchanger on the additionally recovered heat power is studied. A correlation has been derived enabling one to determine the best heat recovery depth (or the final cooling temperature) maximizing the anticipated reduced annual profit of a power enterprise from implementation of energy-saving measures. Results of optimization are presented for a surface-type condensing gas-air plate heat recovery heat exchanger for the climatic conditions and the economic situation in Tomsk. The predictions demonstrate that it is economically feasible to design similar heat recovery heat exchangers for a flue gas outlet temperature of 10°C. In this case, the payback period for the investment in the heat recovery heat exchanger will be 1.5 years. The effect of various factors on the optimal outlet flue gas temperature was analyzed. Most climatic, economical, or technological factors have a minor effect on the best outlet temperature, which remains between 5 and 20°C when varying the affecting factors. The derived correlation enables us to preliminary estimate the outlet (final) flue gas temperature that should be used in designing the heat transfer surface of a heat recovery heat exchanger for a gas-fired boiler as applied to the specific climatic conditions.

  6. ‘That’s when we started using the living room’ : lessons from a local history of domestic heating in the United Kingdom

    Kuijer, L.; Watson, M.

    Indoor climate control forms a major share of residential energy demand. Policy measures to curb this demand tend to focus on energy-efficient technologies. However, while the energy efficiency of domestic heat provision in the United Kingdom (UK) has increased considerably over the past century,

  7. Capability to Recover Plutonium-238 in H-Canyon/HB-Line - 13248

    Fuller, Kenneth S. Jr.; Smith, Robert H. Jr.; Goergen, Charles R. [Savannah River Nuclear Solutions, LLC, Savannah River Site, Aiken, SC 29802 (United States)

    2013-07-01

    Plutonium-238 is used in Radioisotope Thermoelectric Generators (RTGs) to generate electrical power and in Radioisotope Heater Units (RHUs) to produce heat for electronics and environmental control for deep space missions. The domestic supply of Pu-238 consists of scrap material from previous mission production or material purchased from Russia. Currently, the United States has no significant production scale operational capability to produce and separate new Pu-238 from irradiated neptunium-237 targets. The Department of Energy - Nuclear Energy is currently evaluating and developing plans to reconstitute the United States capability to produce Pu-238 from irradiated Np-237 targets. The Savannah River Site had previously produced and/or processed all the Pu-238 utilized in Radioisotope Thermoelectric Generators (RTGs) for deep space missions up to and including the majority of the plutonium for the Cassini Mission. The previous full production cycle capabilities included: Np- 237 target fabrication, target irradiation, target dissolution and Np-237 and Pu-238 separation and purification, conversion of Np-237 and Pu-238 to oxide, scrap recovery, and Pu-238 encapsulation. The capability and equipment still exist and could be revitalized or put back into service to recover and purify Pu-238/Np-237 or broken General Purpose Heat Source (GPHS) pellets utilizing existing process equipment in HB-Line Scrap Recovery, and H-Canyon Frame Waste Recovery processes. The conversion of Np-237 and Pu-238 to oxide can be performed in the existing HB-Line Phase-2 and Phase- 3 Processes. Dissolution of irradiated Np-237 target material, and separation and purification of Np-237 and Pu-238 product streams would be possible at production rates of ∼2 kg/month of Pu-238 if the existing H-Canyon Frames Process spare equipment were re-installed. Previously, the primary H-Canyon Frames equipment was removed to be replaced: however, the replacement project was stopped. The spare equipment

  8. Exergo-economic analysis of finned tube for waste heat recovery including phase change heat transfer

    Wu, Shuang Ying; Jiu, Jing Rui; Xiao, Lan; Li, You Rong; Liu, Chao; Xu, Jin Liang

    2013-01-01

    In this paper, an exergo-economic criterion, i.e. the net profit per unit transferred heat load, is established from the perspective of exergy recovery to evaluate the performance of finned tube used in waste heat recovery. Also, the dimensionless exergy change number is introduced to investigate the effect of the flow (mechanical) exergy loss rate on the recovered thermal exergy. Selecting R245fa as a working fluid and exhaust flue gas as a heat source, the effects of the internal Reynolds number Re_i, the external Reynolds number Re_o , the unit cost of thermal exergy ε_q , the geometric parameter of finned tube η_oβ and the phase change temperature T_v etc. on the performance of finned tube are discussed in detail. The results show that the higher T_v and η_oβ, and lower Re_i may lead to the negligible flow(mechanical) exergy loss rate. There exists an optimal value of Re_i where the net profit per unit transferred heat load peaks, while the variations of Re_o, ε_q and T_v cause monotonic change of the net profit per unit transferred heat load. The phase change temperature exerts relatively greater influence on the exergo-economic performance of finned tube in comparison with other parameters. And there exists a critical phase change temperature, where the net profit per unit transferred heat load is equal to zero.

  9. Mathematical modelling and optimization of a large-scale combined cooling, heat, and power system that incorporates unit changeover and time-of-use electricity price

    Zhu, Qiannan; Luo, Xianglong; Zhang, Bingjian; Chen, Ying

    2017-01-01

    Highlights: • We propose a novel superstructure for the design and optimization of LSCCHP. • A multi-objective multi-period MINLP model is formulated. • The unit start-up cost and time-of-use electricity prices are involved. • Unit size discretization strategy is proposed to linearize the original MINLP model. • A case study is elaborated to demonstrate the effectiveness of the proposed method. - Abstract: Building energy systems, particularly large public ones, are major energy consumers and pollutant emission contributors. In this study, a superstructure of large-scale combined cooling, heat, and power system is constructed. The off-design unit, economic cost, and CO_2 emission models are also formulated. Moreover, a multi-objective mixed integer nonlinear programming model is formulated for the simultaneous system synthesis, technology selection, unit sizing, and operation optimization of large-scale combined cooling, heat, and power system. Time-of-use electricity price and unit changeover cost are incorporated into the problem model. The economic objective is to minimize the total annual cost, which comprises the operation and investment costs of large-scale combined cooling, heat, and power system. The environmental objective is to minimize the annual global CO_2 emission of large-scale combined cooling, heat, and power system. The augmented ε–constraint method is applied to achieve the Pareto frontier of the design configuration, thereby reflecting the set of solutions that represent optimal trade-offs between the economic and environmental objectives. Sensitivity analysis is conducted to reflect the impact of natural gas price on the combined cooling, heat, and power system. The synthesis and design of combined cooling, heat, and power system for an airport in China is studied to test the proposed synthesis and design methodology. The Pareto curve of multi-objective optimization shows that the total annual cost varies from 102.53 to 94.59 M

  10. Heat and Humidity in the City: Neighborhood Heat Index Variability in a Mid-Sized City in the Southeastern United States

    Alisa L. Hass

    2016-01-01

    Full Text Available Daily weather conditions for an entire city are usually represented by a single weather station, often located at a nearby airport. This resolution of atmospheric data fails to recognize the microscale climatic variability associated with land use decisions across and within urban neighborhoods. This study uses heat index, a measure of the combined effects of temperature and humidity, to assess the variability of heat exposure from ten weather stations across four urban neighborhoods and two control locations (downtown and in a nearby nature center in Knoxville, Tennessee, USA. Results suggest that trees may negate a portion of excess urban heat, but are also associated with greater humidity. As a result, the heat index of locations with more trees is significantly higher than downtown and areas with fewer trees. Trees may also reduce heat stress by shading individuals from incoming radiation, though this is not considered in this study. Greater amounts of impervious surfaces correspond with reduced evapotranspiration and greater runoff, in terms of overall mass balance, leading to a higher temperature, but lower relative humidity. Heat index and relative humidity were found to significantly vary between locations with different tree cover and neighborhood characteristics for the full study time period as well as for the top 10% of heat index days. This work demonstrates the need for high-resolution climate data and the use of additional measures beyond temperature to understand urban neighborhood exposure to extreme heat, and expresses the importance of considering vulnerability differences among residents when analyzing neighborhood-scale impacts.

  11. Thermal analysis and modeling of a swimming pool heating system by utilizing waste energy rejected from a chiller unit of an ice rink

    Kuyumcu Muhammed Enes

    2017-01-01

    Full Text Available This study deals with the thermal analysis and modeling of a swimming pool heating system in which the waste energy rejected from the chiller unit of an ice rink is used as an energy source. The system consists of a swimming pool and an ice rink coupled by a chiller unit. The swimming pool and the ice rink both indoor types and were constructed in city of Gaziantep, Turkey. The thermal energy requirement for each section is determined by thermal analysis of each component of the system. Effects of different design parameters such as ceiling insulation thickness, ceiling emissivity, Carnot efficiency factor and size of the ice rink on the thermal energy requirements and coefficient of performance of the chiller unit are investigated. As a result of analyses of the system, the minimum ice rink area is determined in order to meet annual total heat energy demand of the olympic-sized swimming pool.

  12. Flow boiling heat transfer and pressure drop characteristics of R134a, R1234yf and R1234ze in a plate heat exchanger for organic Rankine cycle units

    Zhang, Ji; Desideri, Adriano; Kærn, Martin Ryhl

    2017-01-01

    . This paper is aimed at obtaining flow boiling heat transfer and pressure drop characteristics in a plate heat exchanger under the working conditions prevailing in the evaporator of organic Rankine cycle units. Two hydrofluoroolefins R1234yf and R1234ze, and one hydrofluorocarbon R134a, were selected...... as the working fluids. The heat transfer coefficients and pressure drops of the three working fluids were measured with varying saturation temperatures, mass fluxes, heat fluxes and outlet vapour qualities, which range from 60°C to 80°C, 86 kg/m2 s to 137 kg/m2 s, 9.8 kW/m2 to 36.8 kW/m2 and 0.5 to 1...... developed that are more suitable for evaporation in organic Rankine cycles. The experimental results indicate that heat transfer coefficients are strongly dependent upon the heat flux and saturation temperature. Moreover, the results suggest better thermal-hydraulic performance for R1234yf than the other...

  13. Conceptual design of a FGM thermoelectric energy conversion system for high temperature heat source. 1. Design of thermoelectric energy conversion unit

    Kambe, Mitsuru; Teraki, Junichi; Hirano, Toru.

    1996-01-01

    Thermoelectric (TE) power conversion system has been focused as a candidate of direct energy conversion systems for high temperature heat source to meet the various power requirements in next century. A concept of energy conversion unit by using TE cell elements combined with FGM compliant pads has been presented to achieve high thermal energy density as well as high energy conversion efficiency. An energy conversion unit consists of 8 couples of P-N cell elements sandwiched between two FGM compliant pads. Performance analysis revealed that the power generated by this unit was 11 watts which is nearly ten times as much as conventional unit of the same size. Energy conversion efficiency of 12% was expected based on the assumption of ZT = 1. All the member of compliant pads as well as TE cells could be bonded together to avoid thermal resistance. (author)

  14. Performance of a reversible heat pump/organic Rankine cycle unit coupled with a passive house to get a positive energy building

    Dumont, Olivier; Carmo, Carolina; Fontaine, Valentin

    2016-01-01

    This paper presents an innovative technology that can be used to deliver more renewable electricity production than the total electrical consumption of a building while covering the heat demand on a yearly basis. The technology concept uses a heat pump (HP), slightly modified to revert its cycle...... and generate electricity, coupled to a solar thermal collector roof. This reversible HP/organic Rankine cycle unit presents three operating modes: direct heating, HP and organic Rankine cycle. This work focuses on describing the dynamic model of the multi-component system followed by a techno-economic analysis......Wh/year and total electrical consumption of 2318 kWh/year) with a 138.8 m2 solar roof in Denmark....

  15. STEAM GENERATOR TUBE INTEGRITY ANALYSIS OF A TOTAL LOSS OF ALL HEAT SINKS ACCIDENT FOR WOLSONG NPP UNIT 1

    HEOK-SOON LIM

    2014-02-01

    Full Text Available A total loss of all heat sinks is considered a severe accident with a low probability of occurrence. Following a total loss of all heat sinks, the degasser/condenser relief valves (DCRV become the sole means available for the depressurization of the primary heat transport system. If a nuclear power plant has a total loss of heat sinks accident, high-temperature steam and differential pressure between the primary heat transport system (PHTS and the steam generator (SG secondary side can cause a SG tube creep rupture. To protect the PHTS during a total loss of all heat sinks accident, a sufficient depressurization capability of the degasser/condenser relief valve and the SG tube integrity is very important. Therefore, an accurate estimation of the discharge through these valves is necessary to assess the impact of the PHTS overprotection and the SG tube integrity of the primary circuit. This paper describes the analysis of DCRV discharge capacity and the SG tube integrity under a total loss of all heat sink using the CATHENA code. It was found that the DCRV's discharge capacity is enough to protect the overpressure in the PHTS, and the SG tube integrity is maintained in a total loss of all heat accident.

  16. Steam Generator Tube Integrity Analysis of A Total Loss of all Heat Sinks Accident for Wolsong NPP Unit 1

    Lim, Heoksoon; Song, Taeyoung; Chi, Moongoo [Korea Htydro and Nuclear Power Co., Ltd., Daejeon (Korea, Republic of); Kim, Seoungrae [Nuclear Engineering Service and Solution, Daejeon (Korea, Republic of)

    2014-02-15

    A total loss of all heat sinks is considered a severe accident with a low probability of occurrence. Following a total loss of all heat sinks, the degasser/condenser relief valves (DCRV) become the sole means available for the depressurization of the primary heat transport system. If a nuclear power plant has a total loss of heat sinks accident, high-temperature steam and differential pressure between the primary heat transport system (PHTS) and the steam generator (SG) secondary side can cause a SG tube creep rupture. To protect the PHTS during a total loss of all heat sinks accident, a sufficient depressurization capability of the degasser/condenser relief valve and the SG tube integrity is very important. Therefore, an accurate estimation of the discharge through these valves is necessary to assess the impact of the PHTS overprotection and the SG tube integrity of the primary circuit. This paper describes the analysis of DCRV discharge capacity and the SG tube integrity under a total loss of all heat sink using the CATHENA code. It was found that the DCRV's discharge capacity is enough to protect the overpressure in the PHTS, and the SG tube integrity is maintained in a total loss of all heat accident.

  17. Steam Generator Tube Integrity Analysis of A Total Loss of all Heat Sinks Accident for Wolsong NPP Unit 1

    Lim, Heoksoon; Song, Taeyoung; Chi, Moongoo; Kim, Seoungrae

    2014-01-01

    A total loss of all heat sinks is considered a severe accident with a low probability of occurrence. Following a total loss of all heat sinks, the degasser/condenser relief valves (DCRV) become the sole means available for the depressurization of the primary heat transport system. If a nuclear power plant has a total loss of heat sinks accident, high-temperature steam and differential pressure between the primary heat transport system (PHTS) and the steam generator (SG) secondary side can cause a SG tube creep rupture. To protect the PHTS during a total loss of all heat sinks accident, a sufficient depressurization capability of the degasser/condenser relief valve and the SG tube integrity is very important. Therefore, an accurate estimation of the discharge through these valves is necessary to assess the impact of the PHTS overprotection and the SG tube integrity of the primary circuit. This paper describes the analysis of DCRV discharge capacity and the SG tube integrity under a total loss of all heat sink using the CATHENA code. It was found that the DCRV's discharge capacity is enough to protect the overpressure in the PHTS, and the SG tube integrity is maintained in a total loss of all heat accident

  18. Heat and Mass Transfer during Hydrogen Generation in an Array of Fuel Bars of a BWR Using a Periodic Unit Cell

    H. Romero-Paredes

    2012-01-01

    Full Text Available This paper presents, the numerical analysis of heat and mass transfer during hydrogen generation in an array of fuel cylinder bars, each coated with a cladding and a steam current flowing outside the cylinders. The analysis considers the fuel element without mitigation effects. The system consists of a representative periodic unit cell where the initial and boundary-value problems for heat and mass transfer were solved. In this unit cell, we considered that a fuel element is coated by a cladding with steam surrounding it as a coolant. The numerical simulations allow describing the evolution of the temperature and concentration profiles inside the nuclear reactor and could be used as a basis for hybrid upscaling simulations.

  19. Thermal analysis and modeling of a swimming pool heating system by utilizing waste energy rejected from a chiller unit of an ice rink

    Kuyumcu Muhammed Enes; Yumrutaş Recep

    2017-01-01

    This study deals with the thermal analysis and modeling of a swimming pool heating system in which the waste energy rejected from the chiller unit of an ice rink is used as an energy source. The system consists of a swimming pool and an ice rink coupled by a chiller unit. The swimming pool and the ice rink both indoor types and were constructed in city of Gaziantep, Turkey. The thermal energy requirement for each section is determined by thermal analysis of each component of the system. Effec...

  20. New Turbo Compound Systems in Automotive Industry for Internal Combustion Engine to Recover Energy

    Chiriac, R.; Chiru, A.; Condrea, O.

    2017-10-01

    The large amount of heat is scattered in the internal combustion engine through exhaust gas, coolant, convective and radiant heat transfer. Of all these residual heat sources, exhaust gases have the potential to recover using various modern heat recovery techniques. Waste heat recovery from an engine could directly reduce fuel consumption, increase available electrical power and improve overall system efficiency and if it would be used a turbochargers that can also produce energy. This solution is called turbo aggregation and has other ways to develop it in other areas of research like the electrical field. [1-3

  1. Automated monitoring of recovered water quality

    Misselhorn, J. E.; Hartung, W. H.; Witz, S. W.

    1974-01-01

    Laboratory prototype water quality monitoring system provides automatic system for online monitoring of chemical, physical, and bacteriological properties of recovered water and for signaling malfunction in water recovery system. Monitor incorporates whenever possible commercially available sensors suitably modified.

  2. Probabilistic assessment of the potential indoor air impacts of vent-free gas heating appliances in energy-efficient homes in the United States.

    Whitmyre, Gary K; Pandian, Muhilan D

    2018-06-01

    Use of vent-free gas heating appliances for supplemental heating in U.S. homes is increasing. However, there is currently a lack of information on the potential impact of these appliances on indoor air quality for homes constructed according to energy-efficient and green building standards. A probabilistic analysis was conducted to estimate the impact of vent-free gas heating appliances on indoor air concentrations of carbon monoxide (CO), nitrogen dioxide (NO 2 ), carbon dioxide (CO 2 ), water vapor, and oxygen in "tight" energy-efficient homes in the United States. A total of 20,000 simulations were conducted for each Department of Energy (DOE) heating region to capture a wide range of home sizes, appliance features, and conditions, by varying a number of parameters, e.g., room volume, house volume, outdoor humidity, air exchange rates, appliance input rates (Btu/hr), and house heat loss factors. Predicted airborne levels of CO were below the U.S. Environmental Protection Agency (EPA) standard of 9 ppm for all modeled cases. The airborne concentrations of NO 2 were below the U.S. Consumer Product Safety Commission (CPSC) guideline of 0.3 ppm and the Health Canada benchmark of 0.25 ppm in all cases and were below the World Health Organization (WHO) standard of 0.11 ppm in 99-100% of all cases. Predicted levels of CO 2 were below the Health Canada standard of 3500 ppm for all simulated cases. Oxygen levels in the room of vent-free heating appliance use were not significantly reduced. The great majority of cases in all DOE regions were associated with relative humidity (RH) levels from all indoor water vapor sources that were less than the EPA-recommended 70% RH maximum to avoid active mold and mildew growth. The conclusion of this investigation is that when installed in accordance with the manufacturer's instructions, vent-free gas heating appliances maintain acceptable indoor air quality in tight energy-efficient homes, as defined by the standards referenced in

  3. Heat unit accumulation and inflorescence and fruit development in ‘Ubá’ mango trees grown in Visconde do Rio Branco-MG

    Lorena Moreira Carvalho Lemos

    2018-04-01

    Full Text Available Abstract There are little information in the scientific literature on flowering and fruiting of ‘Ubá’ mango trees. These information enables to know the proportion of hermaphrodite flowers in inflorescence, fruit set percentage and developmental stages of the fruit. In this study evaluations on inflorescence and fruit development of the ‘Ubá’ mango tree (Mangifera indica L. were carried out, as well as the determination of the required number of heat units for full fruit development. Thirty branches whose terminal buds were swollen were selected from five mango trees. With the aid of a camera and a caliper, the panicle and fruit development were evaluated weekly until full fruit development. A digital thermometer was used to record ambient temperatures during fruit development in order to estimate the number of heat units required for complete development of the fruits. Male and hermaphrodite flowers of the panicles were also identified and counted. The developmental cycle of ‘Ubá’ mango from the beginning of apical bud swelling to commercial harvest of the fruit lasted 168 days in 2011 and 154 days in 2012. The number of hermaphrodite flowers and the percentage of fruit set in the inflorescence in 2011 were 32.3 and 0.066%, respectively; and 122.1 and 0.099% in 2012, respectively. There was accumulation of 3,173 heat units from flower bud swelling to full development of the ‘Ubá’ mangoes.

  4. New arrangement for the air cleanup system to recover tritium

    Nishikawa, Masabumi; Takahashi, Kohsaku; Munakata, Kenzo; Fukada, Satoshi; Kotoh, Kenji; Takeishi, Toshiharu

    1997-01-01

    At present, the standard arrangement of the air cleanup system responsible for emergency tritium recovery from room air is a catalytic oxidation bed with a heater followed by an adsorption bed with a cooler. One disadvantage of this arrangement is that trouble with the heater or the cooler could result in a loss of capacity to recover tritium. Another disadvantage of the catalyst-adsorption-bed arrangement is that tritiated water must be recovered with a high decontamination factor after dilution with a large amount of water vapor in the working atmosphere. The performance of a new arrangement for the air cleanup system, which consists of a precious metal catalyst bed preceded by an adsorption bed without heating equipment, is discussed. According to calculations, most of the tritium released to the room air is recovered in the catalyst bed through oxidation, adsorption, and isotope exchange reaction when the new arrangement is applied. The adsorption bed placed before the catalyst bed dehumidifies the process gas to such a degree that the oxidation reaction of tritium in the catalyst bed is not hindered by water vapor. 15 refs., 6 figs., 6 tabs

  5. Split heat pipe heat recovery system

    E. Azad

    2008-01-01

    This paper describes a theoretical analysis of a split heat pipe heat recovery system. The analysis is based on an Effectiveness-NTU approach to deduce its heat transfer characteristics. In this study the variation of overall effectiveness of heat recovery with the number of transfer units are presented. Copyright , Manchester University Press.

  6. Assessment of the Long Term Trends in Extreme Heat Events and the Associated Health Impacts in the United States

    Bell, J.; Rennie, J.; Kunkel, K.; Herring, S.; Cullen, H. M.

    2017-12-01

    Land surface air temperature products have been essential for monitoring the evolution of the climate system. Before a temperature dataset is included in such reports, it is important that non-climatic influences be removed or changed so the dataset is considered homogenous. These inhomogeneities include changes in station location, instrumentation and observing practices. While many homogenized products exist on the monthly time scale, few daily products exist, due to the complication of removing breakpoints that are truly inhomogeneous rather than solely by chance (for example, sharp changes due to synoptic conditions). Recently, a sub monthly homogenized dataset has been developed using data and software provided by NOAA's National Centers for Environmental Information (NCEI). Homogeneous daily data are useful for identification and attribution of extreme heat events over a period of time. Projections of increasing temperatures are expected to result in corresponding increases in the frequency, duration, and intensity of extreme heat events. It is also established that extreme heat events can have significant public health impacts, including short-term increases in mortality and morbidity. In addition, it can exacerbate chronic health conditions in vulnerable populations, including renal and cardiovascular issues. To understand how heat events impact a specific population, it will be important to connect observations on the duration and intensity of extreme heat events with health impacts data including insurance claims and hospital admissions data. This presentation will explain the methodology to identify extreme heat events, provide a climatology of heat event onset, length and severity, and explore a case study of an anomalous heat event with available health data.

  7. An assessment of the present and future opportunities for combined heat and power with district heating (CHP-DH) in the United Kingdom

    Kelly, Scott; Pollitt, Michael

    2010-01-01

    As global fuel reserves are depleted, alternative and more efficient forms of energy generation and delivery will be required. Combined heat and power with district heating (CHP-DH) provides an alternative energy production and delivery mechanism that is less resource intensive, more efficient and provides greater energy security than many popular alternatives. It will be shown that the economic viability of CHP-DH networks depends on several principles, namely (1) the optimisation of engineering and design principles; (2) organisational and regulatory frameworks; (3) financial and economic factors. It was found that in the long term DH is competitive with other energy supply and distribution technologies such as electricity and gas. However, in the short to medium term it is shown that economic risk, regulatory uncertainty and lock-in of existing technology are the most significant barriers to CHP-DH development. This research suggests that under the present regulatory and economic paradigm, the infrastructure required for DH networks remains financially prohibitive; the implementation of government policies are complicated and impose high transaction costs, while engineering solutions are frequently not implemented or economically optimised. If CHP-DH is going to play any part in meeting climate change targets then collaboration between public and private organisations will be required. It is clear from this analysis that strong local government involvement is therefore necessary for the co-ordination, leadership and infrastructural deployment of CHP-DH.

  8. Layout of heating units for solar-heated gas turbine systems with paraboloid collectors. Die Auslegung von Erhitzern Solar beheizter Gasturbinenanlagen mit Paraboloidkollektoren

    Seifert, P

    1983-07-04

    Solar energy is converted in a gas turbine plant, with solar radiation collected in a parabolic collector and reflected into a hollow receiver. The receiver, which is rigidly connected to the collector, consists of a conical bottom part and a cylindrical upper part. The highly focussed radiation enters through the aperture of the conus. The cool, compressed working fluid of the gas turbine flows through pipes arranged in front of the cylindrical inner wall. The distribution of the radiation was studied as well as the resulting receiver wall temperature, radiation losses and useful heat absorbed by the working fluid. Temperature distributions and three-dimensional fields of thermal stresses were calculated. The influence of geometric and thermodynamic parameters on the stresses inside the pipes was studied in consideration of thermal stresses and stresses due to working fluid pressure. The findings will help to optimize the heating surface load, material utilisation, and efficiency of the receiver. The interdependences between receiver characteristics and gas turbine operation are explained.

  9. Gas heat pump installation at Paderborn

    1978-01-01

    A gas heat pump installation at the swimming pool and sport center in Paderborn, developed by Ruhrgas A.G. has a heat capacity of 4650 kW, the largest up to this time and recovers heat from ground water under the sport center, shower, and swimming pool effluent, and air exhausted from the swimming pool to provide 182% of the energy obtained from the natural gas alone. This compares with an 80% efficiency for a conventional boiler fired with natural gas. Natural gas consumption by the sport center has been reduced from 1.2 million m/sup 3/ y to 520,000 m/sup 3//y, a 56% savings. Three identical units each have an eight-cylinder, four-cycle, 253 kW-gas engine.

  10. Cognitive bias in symptomatic and recovered agoraphobics.

    Stoler, L S; McNally, R J

    1991-01-01

    Symptomatic agoraphobics, recovered agoraphobics, and normal control subjects completed a series of sentence stems that had either ambiguous or unambiguous meanings, and had either a potentially threatening or a nonthreatening connotation. The written completions made by subjects to these stems were classified as indicating either a biased (i.e. threat-related) or unbiased interpretation of the meaning of the stem, and if a biased interpretation was made, whether the subject indicated efforts at adaptive coping with the perceived threat. Results indicated that symptomatic agoraphobics exhibited strong biases for interpreting information as threatening, relative to normal control subjects. Moreover, recovered agoraphobics resembled symptomatic agoraphobics more than normal control subjects, thus indicating that cognitive biases may persist following cessation of panic attacks and reductions in avoidance behavior. However, recovered agoraphobics also exhibited tendencies to cope adaptively with perceived threats whereas symptomatic agoraphobics did not.

  11. Ergonomic analysis jobs in recovered factories.

    Cuenca, Gabriela; Zotta, Gastón

    2012-01-01

    With the advent of the deep economic crisis in Argentina on 2001, the recovery of companies through to the creation of the Cooperatives Working Self-Management or Factories Recovered by its workers was constituted as one of the ways in which the salaried disobeyed the increasing unemployment. When the companies turn into recovered factories they tend to leave of side practices that have been seen like imposed by the previous organization and not understanding them as a primary condition for the execution of his tasks. Safety and ergonomics are two disciplines that are no longer considered relevant to the daily work. Therefore this investigation aims to revalue, undergo semantic to give back to a place in every organization analyzed. This research developed a self-diagnostic tool for working conditions, and the environment, present in the recovered factories.

  12. Numerical Study of the Dynamic Response of Heat and Mass Transfer to Operation Mode Switching of a Unitized Regenerative Fuel Cell

    Hong Xiao

    2016-12-01

    Full Text Available Knowledge concerning the complicated changes of mass and heat transfer is desired to improve the performance and durability of unitized regenerative fuel cells (URFCs. In this study, a transient, non-isothermal, single-phase, and multi-physics mathematical model for a URFC based on the proton exchange membrane is generated to investigate transient responses in the process of operation mode switching from fuel cell (FC to electrolysis cell (EC. Various heat generation mechanisms, including Joule heat, reaction heat, and the heat attributed to activation polarizations, have been considered in the transient model coupled with electrochemical reaction and mass transfer in porous electrodes. The polarization curves of the steady-state models are validated by experimental data in the literatures. Numerical results reveal that current density, gas mass fractions, and temperature suddenly change with the sudden change of operating voltage in the mode switching process. The response time of temperature is longer than that of current density and gas mass fractions. In both FC and EC modes, the cell temperature and gradient of gas mass fraction in the oxygen side are larger than that in the hydrogen side. The temperature difference of the entire cell is less than 1.5 K. The highest temperature appears at oxygen-side catalyst layer under the FC mode and at membrane under a more stable EC mode. The cell is exothermic all the time. These dynamic responses and phenomena have important implications for heat analysis and provide proven guidelines for the improvement of URFCs mode switching.

  13. CO{sub 2} reduction: potential of heat pumps when used together with combined heat and power units; Potentiel energetique des pompes a chaleur combinees au couplage chaleur-force. Pour une reduction maximale des emissions de CO{sub 2} et pour une production de courant fossile avec reduction des emissions de CO{sub 2} en Suisse - Rapport final

    Rognon, F.

    2005-07-01

    This final report for the Swiss Federal Office of Energy (SFOE) presents the results of a project that examined the potential of using heat pumps in combination with Combined Heat and Power (CHP) units as a replacement for fossil-fuel fired heating units in Switzerland. The electrical power produced by the CHP units can be used to provide power for the drives of heat pump systems. The author states that the fossil fuel consumption and the resulting emissions of carbon dioxide can be halved using this combination. Also, even more efficient systems using power produced in larger combined-cycle power generation are discussed. Further examples of how fossil-fired power generation in combination with heat pumps can not only replace fossil-fuelled heating systems but also provide additional electricity too are given. This overview includes figures on the potential of such combined systems.

  14. Solid recovered fuels in the steel industry.

    Kepplinger, Werner L; Tappeiner, Tamara

    2012-04-01

    By using waste materials as alternative fuels in metallurgical plants it is possible to minimize the traditionally used reducing agents, such as coke, coal, oil or natural gas. Moreover, by using waste materials in the metallurgical industry it is feasible to recover these materials as far as possible. This also represents another step towards environmental protection because carbon dioxide emissions can be reduced, if the H(2) content of the waste material is greater in comparison with that of the substituted fuel and the effects of global warming can therefore be reduced. In the present article various solid recovered fuels and their applications in the metallurgical industry are detailed.

  15. Steady natural convection heat transfer experiments in a horizontal annulus for the United States Spent Fuel Shipping Cask Technology Program

    Boyd, R.D.

    1981-04-01

    This experimental study deals with the measurement of the heat transfer across a horizontal annulus which is formed by an inner hexagonal cylinder and an outer concentric circular cylinder. The geometry simulates, in two dimensions, a liquid metal fast breeder reactor radioactive fuel subassembly inside a shipping container. This geometry is also similar to a radioactive fuel pin inside a horizontal reactor subassembly. The objective of the experiments is to measure the local and mean heat transfer at the surface of the inner hexagonal cylinder

  16. European ErP Directive. Total condensing technology: the solution for heating and DHW units in the hotel sector

    Martín, G.

    2016-01-01

    Since 26 September 2015, the Ecodesign ErP Directive has been of compulsory application for EU Member States as regards the design of Energy-related Products (ErP) and as from its entry into force only those products manufactured according to the ErP requirements can be sold with the EC label. Although this directive affects over 1,000 product categories, for those relating to HVAC and DHW production, it covers boilers, heat pumps, accumulators, cogeneration systems, combined products systems, establishing their minimum efficiency levels, the maximum levels of NOX emissions, the minimum insulation for accumulators and the maximum level of acoustic emissions for heat pumps. (Author)

  17. Heat pipes for ground heating and cooling

    Vasiliev, L L

    1988-01-01

    Different versions of heat pipe ground heating and cooling devices are considered. Solar energy, biomass, ground stored energy, recovered heat of industrial enterprises and ambient cold air are used as energy and cold sources. Heat pipe utilization of air in winter makes it possible to design accumulators of cold and ensures deep freezing of ground in order to increase its mechanical strength when building roadways through the swamps and ponds in Siberia. Long-term underground heat storage systems are considered, in which the solar and biomass energy is accumulated and then transferred to heat dwellings and greenhouses, as well as to remove snow from roadways with the help of heat pipes and solar collectors.

  18. Assessment of Coping Capability of KORI Unit 1 under Extended Loss AC Power and Loss of Ultimate Heat Sink Initiated by Beyond Design Natural Disaster

    Kim, Chang Hyun; Ha, Sang Jun [KHNP CRI, Daejeon (Korea, Republic of); Han, Kee Soo [Nuclear Engineering Service and Solution (NESS) Co. Ltd., Deajeon (Korea, Republic of); Park, Chan Eok [KEPCO Engineering and Constructd., Deajeon (Korea, Republic of)

    2016-10-15

    In Korea, the government and industry performed comprehensive safety inspection on all domestic nuclear power plants against beyond design basis external events and fifty action items have been issued. In addition to post- Fukushima action items, the stress tests for all domestic nuclear power plants are on the way to enhance the safety of domestic nuclear power plants through finding the vulnerabilities in intentional stress conditions initiated by beyond design natural disaster. This paper presents assessment results of coping capability of KORI Unit 1 under the simultaneous Extended Loss of AC Power (ELAP) and Loss of Ultimate Heat Sink (LUHS) which is a representative plant condition initiated by beyond design natural disaster. The assessment of the coping capability of KORI Unit 1 has been performed under simultaneous the extended loss of AC power and loss of ultimate heat sink initiated by beyond design natural disaster. It is concluded that KORI Unit 1 has the capability, in the event of loss of safety functions by beyond design natural disaster, to sufficiently cool down the reactor core without fuel damage, to keep pressure boundaries of the reactor coolant system in transient condition and to control containment and temperature to maintain the integrity of the containment buildings.

  19. Assessment of Coping Capability of KORI Unit 1 under Extended Loss AC Power and Loss of Ultimate Heat Sink Initiated by Beyond Design Natural Disaster

    Kim, Chang Hyun; Ha, Sang Jun; Han, Kee Soo; Park, Chan Eok

    2016-01-01

    In Korea, the government and industry performed comprehensive safety inspection on all domestic nuclear power plants against beyond design basis external events and fifty action items have been issued. In addition to post- Fukushima action items, the stress tests for all domestic nuclear power plants are on the way to enhance the safety of domestic nuclear power plants through finding the vulnerabilities in intentional stress conditions initiated by beyond design natural disaster. This paper presents assessment results of coping capability of KORI Unit 1 under the simultaneous Extended Loss of AC Power (ELAP) and Loss of Ultimate Heat Sink (LUHS) which is a representative plant condition initiated by beyond design natural disaster. The assessment of the coping capability of KORI Unit 1 has been performed under simultaneous the extended loss of AC power and loss of ultimate heat sink initiated by beyond design natural disaster. It is concluded that KORI Unit 1 has the capability, in the event of loss of safety functions by beyond design natural disaster, to sufficiently cool down the reactor core without fuel damage, to keep pressure boundaries of the reactor coolant system in transient condition and to control containment and temperature to maintain the integrity of the containment buildings

  20. Department of Defense Recovering Warrior Task Force

    2014-09-02

    accessible and available to the Veterans Benefits Administration ( VBA ) as soon as possible381; however, because military service records include health...programs are meeting expectations ........................................... 35 Facilitating Access to Health Care...Enduring RW Mission, Facilitating RW Recovery and Transition, and Facilitating Access to Health Care. SUMMARY 2  DoD Recovering Warrior Task Force

  1. Recovering Parameters of Johnson's SB Distribution

    Bernard R. Parresol

    2003-01-01

    A new parameter recovery model for Johnson's SB distribution is developed. This latest alternative approach permits recovery of the range and both shape parameters. Previous models recovered only the two shape parameters. Also, a simple procedure for estimating the distribution minimum from sample values is presented. The new methodology...

  2. Process for recovering oil from shale, etc

    1920-08-20

    A process is described for recovering oil from oil-shale and the like, by the direct action of the hot gases obtained by burning the carbonized shale residue. It is immediately carried out in separate adjacent chambers, through which the feed goes from one to the other intermittently, from the upper to the lower.

  3. Recovering uranium from coal in situ

    Terry, R.C.

    1978-01-01

    An underground carbonaceous deposit containing other mineral values is burned in situ. The underground hot zone is cooled down to temperature below the boiling point of a leachig solution. The leaching solution is percolated through the residial ash, with the pregnant solution recovered for separation of the mineral values in surface facilities

  4. Applications for Energy Recovering Free Electron Lasers

    George Neil

    2007-08-01

    The availability of high-power, high-brilliance sources of tunable photons from energy-recovered Free Electron Lasers is opening up whole new fields of application of accelerators in industry. This talk will review some of the ideas that are already being put into production, and some of the newer ideas that are still under development.

  5. Design of a unit to produce hot distilled water for the same power consumption as a water heater

    Bambenek, R. A.; Nuccio, P. P.

    1973-01-01

    Unit recovers 97% of water contained in pretreated waste water. Some factors are: cleansing agent prevents fouling of heat transfer surface by highly concentrated waste; absence of dynamic seals reduces required purge gas flow rate; and recycle loop maintains constant flushing process to carry cleansing agent across evaporation surface.

  6. Energy Savings and Economics of Advanced Control Strategies for Packaged Air-Conditioning Units with Gas Heat

    Wang, Weimin; Katipamula, Srinivas; Huang, Yunzhi; Brambley, Michael R.

    2011-12-31

    Pacific Northwest National Laboratory (PNNL) with funding from the U.S. Department of Energy's Building Technologies Program (BTP) evaluated a number of control strategies that can be implemented in a controller, to improve the operational efficiency of the packaged air conditioning units. The two primary objectives of this research project are: (1) determine the magnitude of energy savings achievable by retrofitting existing packaged air conditioning units with advanced control strategies not ordinarily used for packaged units and (2) estimating what the installed cost of a replacement control with the desired features should be in various regions of the U.S. This document reports results of the study.

  7. Results of Steam-Water-Oxygen Treatment of the Inside of Heating Surfaces in Heat-Recovery Steam Generators of the PGU-800 Power Unit at the Perm' District Thermal Power Station

    Ovechkina, O. V.; Zhuravlev, L. S.; Drozdov, A. A.; Solomeina, S. V.

    2018-05-01

    Prestarting, postinstallation steam-water-oxygen treatment (SWOT) of the natural circulation/steam reheat heat-recovery steam generators (HRSG) manufactured by OAO Krasny Kotelshchik was performed at the PGU-800 power unit of the Perm District Thermal Power Station (GRES). Prior to SWOT, steam-oxygen cleaning, passivation, and preservation of gas condensate heaters (GCH) of HRSGs were performed for 10 h using 1.3MPa/260°C/70 t/h external steam. After that, test specimens were cut out that demonstrated high strength of the passivating film. SWOT of the inside of the heating surfaces was carried out during no-load operation of the gas turbine unit with an exhaust temperature of 280-300°C at the HRSG inlet. The steam turbine was shutdown, and the generated steam was discharged into the atmosphere. Oxygen was metered into the discharge pipeline of the electricity-driven feed pumps and downcomers of the evaporators. The behavior of the concentration by weight of iron compounds and the results of investigation of cutout specimens by the drop or potentiometric method indicate that the steam-water-oxygen process makes it possible to remove corrosion products and reduce the time required to put a boiler into operation. Unlike other processes, SWOT does not require metal-intensive cleaning systems, temporary metering stations, and structures for collection of the waste solution.

  8. Biogas combined-heat-and-power-unit in practice: emission behaviour and performance behaviour; Biogas-BHKW in der Praxis: Emissions- und Leistungsverhalten

    Aschmann, V.; Kissel, R.; Gronauer, A. [Bayerische Landesanstalt fuer Landwirtschaft (LfL), Freising-Weihenstephan (Germany). Inst. fuer Landtechnik und Tierhaltung

    2007-07-01

    The electrical power output of the combined-heat-and-power-unit (CHPU) is prioritized when biogas is used for electricity production. However, during servicing and adjusting of engines, beside power output, exhaust gas emissions should also be taken into consideration. Investigations at several biogas driven CHPU prior to maintenance revealed NO{sub x}-levels in the exhaust gas that were in part considerably in excess of respective limit values. The limit values could be met by servicing and adjusting the engine, but this resulted in decreased electrical efficiency and power output. (orig.)

  9. A new tool of decentralized power supply. Micro-cogeneration unit for heat and power supply; Neuer Spielball der dezentralen Energieversorgung. Mikro-Waermekraftkopplung liefert Strom und Waerme

    Anon.

    2001-07-01

    Small fuel cell heating systems have renewed interest in decentralized power supply. The Dutch company EnAtEc recently announced their intention of presenting a micro-cogeneration unit ({mu}WK) at this year's ISH. The unit is a combination of a gas-fuelled high-efficiency boiler and a free-piston Stirling engine. With 1 kW{sub el} and 6 - 24 kW{sub th} it is suited for single-family dwellings. [German] Kleine Brennstoffzellenheizgeraete haben eine rege Diskussion um die dezentrale Energieversorgung entfacht. Juengst ueberraschte die niederlaendische Firma EnAtEc mit der Ankuendigung, zur ISH eine ''Mikro-Waermekraftkopplung'' ({mu}WK) vorzustellen. Das Geraet kombiniert einen Gas-Brennwertkessel mit einer Freikolben-Stirlingmaschine. Mit Leistungen von 1 kW{sub el} und 6 bis 24 kW{sub th} zielt die {mu}WK auf Einfamilienhaushalte. (orig.)

  10. NUMERICAL MODELING OF CONJUGATE HEAT TRANSFER IN AN INSULATED GLASS UNIT (IGU WITH ACCOUNT FOR ITS DEFORMATION

    Golubev Stanislav Sergeevich

    2012-12-01

    The effects of different climatic impacts lead to the deformation of glasses within an IGU (and its vertical cavity, respectively. Deformation of glasses and vertical cavities reduces the thermal resistance of an IGU. A numerical simulation of conjugate heat transfer within an IGU was implemented as part of the research into this phenomenon. Calculations were performed in ANSYS FLUENT CFD package. Basic equations describing the conservation of mass, conservation of momentum (in the Boussinesq approximation, conservation of energy were solved. Also, the radiation of the cavity wall was taken into account. Vertical walls were considered as non-isothermal, while horizontal walls were adiabatic. Calculations were made for several patterns of glass deformations. Calculation results demonstrate that the heat flow over vertical walls intensifies as the distance between centres of IGU glasses is reduced. The temperature in the central area of the hot glass drops.

  11. Solar unit

    Sukhanov, A M; Trushevskiy, S N; Tveryanovich, E V

    1982-01-01

    A solar unit is proposed which contains an inclined solar collector with supply and outlet pipelines, the first of which is connected to the source of a heat carrier, while the second is connected through the valve to the tank for collecting heated heat carrier equipped with a device for recovery. In order to improve the effectiveness of heating the heat carrier, it additionally contains a concentrator of solar radiation and a device for maintaining a level of the heat carrier in the collector in the zone of the focal spot of the concentrator, while the heat pipeline is connected to the source of the heat carrier with the help of a device for maintaining the level of the heat carrier.

  12. Heat Stroke

    Mørch, Sofie Søndergaard; Andersen, Johnny Dohn Holmgren; Bestle, Morten Heiberg

    2017-01-01

    not diagnosed until several days after admittance; hence treatment with cooling was delayed. Both patients were admitted to the intensive care unit, where they were treated with an external cooling device and received treatment for complications. Both cases ended fatally. As global warming continues, more heat......Heat stroke is an acute, life-threatening emergency characterized clinically by elevated body temperature and central nervous system dysfunction. Early recognition and treatment including aggressive cooling and management of life-threatening systemic complications are essential to reduce morbidity...... and mortality. This case report describes two Danish patients diagnosed with heat stroke syndrome during a heat wave in the summer of 2014. Both patients were morbidly obese and had several predisposing illnesses. However since heat stroke is a rare condition in areas with temperate climate, they were...

  13. Recovering of images degraded by atmosphere

    Lin, Guang; Feng, Huajun; Xu, Zhihai; Li, Qi; Chen, Yueting

    2017-08-01

    Remote sensing images are seriously degraded by multiple scattering and bad weather. Through the analysis of the radiative transfer procedure in atmosphere, an image atmospheric degradation model considering the influence of atmospheric absorption multiple scattering and non-uniform distribution is proposed in this paper. Based on the proposed model, a novel recovering method is presented to eliminate atmospheric degradation. Mean-shift image segmentation and block-wise deconvolution are used to reduce time cost, retaining a good result. The recovering results indicate that the proposed method can significantly remove atmospheric degradation and effectively improve contrast compared with other removal methods. The results also illustrate that our method is suitable for various degraded remote sensing, including images with large field of view (FOV), images taken in side-glance situations, image degraded by atmospheric non-uniform distribution and images with various forms of clouds.

  14. New waste heat district heating system with combined heat and power based on absorption heat exchange cycle in China

    Sun Fangtian; Fu Lin; Zhang Shigang; Sun Jian

    2012-01-01

    A new waste heat district heating system with combined heat and power based on absorption heat exchange cycle (DHAC) was developed to increase the heating capacity of combined heat and power (CHP) through waste heat recovery, and enhance heat transmission capacity of the existing primary side district heating network through decreasing return water temperature by new type absorption heat exchanger (AHE). The DHAC system and a conventional district heating system based on CHP (CDH) were analyzed in terms of both thermodynamics and economics. Compared to CDH, the DHAC increased heating capacity by 31% and increased heat transmission capacity of the existing primary side district heating network by 75%. The results showed that the exergetic efficiency of DHAC was 10.41% higher and the product exergy monetary cost was 36.6¥/GJ less than a CHD. DHAC is an effective way to increase thermal utilization factor of CHP, and to reduce district heating cost. - Highlights: ► Absorption heat pumps are used to recover waste heat in CHP. ► Absorption heat exchanger can reduce exergy loss in the heat transfer process. ► New waste heat heating system (DHAC) can increase heating capacity of CHP by 31%. ► DHAC can enhance heat transmission capacity of the primary pipe network by 75%. ► DHAC system has the higher exergetic efficiency and the better economic benefit.

  15. Method for recovering uranium from sea water

    Schwochau, K.; Astheimer, L.; Schenk, H.J.; Schmitz, J.

    1977-04-01

    In view of the augmenting uranium demand for energy supply and of the anticipated depletion of the actually assured and economic uranium resources the possibility of recovering uranium from sea water receives increasing attention. It is the purpose of the present report to give a detailed discussion of fundamental problems involved and a critical survey of hitherto proposed processes of recovery and to recommend some general directives for further work. (orig.) [de

  16. A dynamic regrouping based sequential dynamic programming algorithm for unit commitment of combined heat and power systems

    Rong, Aiying; Hakonen, Henri; Lahdelma, Risto

    2009-01-01

    efficiency of the plants. We introduce in this paper the DRDP-RSC algorithm, which is a dynamic regrouping based dynamic programming (DP) algorithm based on linear relaxation of the ON/OFF states of the units, sequential commitment of units in small groups. Relaxed states of the plants are used to reduce...... the dimension of the UC problem and dynamic regrouping is used to improve the solution quality. Numerical results based on real-life data sets show that this algorithm is efficient and optimal or near-optimal solutions with very small optimality gap are obtained....

  17. Process heat recovery: hot prospects

    1982-03-01

    By updating established technologies to recover heat at higher temperatures and under more corrosive conditions, British industry could recover six to eight million tons of coal equivalent that it currently wastes. Organic liquids in organic Rankine cycle (ORC) engines and simpler designs than steam turbines can increase efficiency. They also eliminate the need for vacuum pumps and permit the use of air cooling. Cooperative government-private industry research programs are exploring the use of ORC engines. Other heat-recovery projects include a Scottish paper mill, a metal decorating and printing plant, a falling-cloud heat exchanger, and heat-pipe development. 4 figures, 1 table. (DCK)

  18. Recovering hydrocarbons with surfactants from lignin

    Naae, D.G.; Whittington, L.E.; Ledoux, W.A.; Debons, F.E.

    1988-11-29

    This patent describes a method of recovering hydrocarbons from an underground hydrocarbon formation penetrated by at least one injection well and at least one production well, which comprises: injecting into the formation through an injection well a surfactant slug comprising about 0.1% to about 10% by weight of surfactants produced from lignin, the surfactants produced by placing lignin in contact with water, converting the lignin into low molecular weight lignin phenols by reducing the lignin in the presence of a reducing agent of carbon monoxide or hydrogen creating a reduction reaction mixture comprising oil soluble lignin phenols, the reduction occurring at a temperature greater than about 200/sup 0/C and a pressure greater than about 100 psi, recovering the oil soluble lignin phenols from the reduction mixture, and converting the lignin phenols into lignin surfactants by a reaction selected from the group consisting of alkoxylation, sulfonation, sulfation, aklylation, sulfomethylation, and alkoxysulfation; injecting into the formation through the injection well a drive fluid to push the surfactant slug towards a production well; and recovering hydrocarbons at the production well.

  19. Process for recovering xenon from radioactive gaseous wastes

    Kishimoto, Tsuneo.

    1980-01-01

    Purpose: To recover pure xenon economically and efficiently by amply removing radioactive krypton mixed in xenon without changing the rectifying capacity of an xenon rectifying system itself. Method: Xe containing radioactive Kr(Kr-85) is rectified to reduce the concentration of radioactive Kr. Thereafter, non-radioactive Kr or Ar is added to Xe and further the rectification is carried out. The raw material Xe from the Xe adsorption system of, for example, a radioactive gaseous waste disposal system is cooled to about 100 0 C by a heat-exchanger and thereafter supplied to a rectifying tower to carry out normal rectification of Xe thereby to reduce the concentration of Kr contained in Xe at the tower bottom to the rectification limit concentration. Then, non-radioactive Kr is supplied via a precooler to the tower bottom to continue the rectification, thus the Xe fractions at the tower bottom, in which the concentration of radioactive Kr is reduced, being compressed and recovered. (Kamimura, M.)

  20. An improvement of the base bleed unit on base drag reduction and heat energy addition as well as mass addition

    Xue, Xiaochun; Yu, Yonggang

    2016-01-01

    Highlights: • A 2D axisymmetric Navier-Stokes equation for a multi-component reactive system is solved. • The coupling of the internal and wake flow field with secondary combustion is calculated. • Detailed data with combined effects of boattailing and post-combustion are obtained. • The mechanism of heat energy addition and thermodynamics performances is investigated. - Abstract: Numerical simulations are carried out to investigate the base drag and energy characteristics of a base-bleed projectile with and without containing the effect of a post-combustion process for a boattailed afterbody in a supersonic flow, and then to analyze the key factor of drag reduction and pressure decreasing of base bleed projectile. Detailed chemistry models for H_2−CO combustion have been incorporated into a Navier-Stokes computer code and applied to flow field simulation in the base region of a base-bleed projectile. Detailed numerical results for the flow patterns and heat energy addition as well as mass addition for different conditions are presented and compared with existing experimental data. The results shows that, the post-combustion contributes to energy addition and base drag reduction up to 78% on account of that the heat energy released from the post-combustion using fuel-rich reaction products as the fuel in the wake region is much higher than for the corresponding cold bleed and hot bleed cases. In addition, the temperature distribution regularities are changed under post-combustion effect, presenting that the peak appears in a couple of recirculation regions. The fuel-rich bleed gas flows into the shear layer along the crack between these two recirculation regions and then those can readily burn when mixing with the freestream, thus causing component changes of H_2 and CO in the base flowfield.

  1. Monitoring Urban Heat Island Through Google Earth Engine: Potentialities and Difficulties in Different Cities of the United States

    Ravanelli, R.; Nascetti, A.; Cirigliano, R. V.; Di Rico, C.; Monti, P.; Crespi, M.

    2018-04-01

    The aim of this work is to exploit the large-scale analysis capabilities of the innovative Google Earth Engine platform in order to investigate the temporal variations of the Urban Heat Island phenomenon as a whole. A intuitive methodology implementing a largescale correlation analysis between the Land Surface Temperature and Land Cover alterations was thus developed.The results obtained for the Phoenix MA are promising and show how the urbanization heavily affects the magnitude of the UHI effects with significant increases in LST. The proposed methodology is therefore able to efficiently monitor the UHI phenomenon.

  2. Thermodynamic and economic analysis of integrating lignocellulosic bioethanol production in a Danish combined heat and power unit

    Lythcke-Jørgensen, Christoffer Ernst; Haglind, Fredrik; Clausen, Lasse Røngaard

    bioethanol production in the Danish CHP unit Avedøreværket 1. Numerical models of the plants were developed, and feasible integration solutions were identified and optimised using exergy analysis. Hour-wise production simulations were run over a reference year, and market prices and economic parameters from...

  3. A parametric study of a humidification dehumidification (HDH) desalination system using low grade heat sources

    He, W.F.; Han, D.; Yue, C.; Pu, W.H.

    2015-01-01

    Highlights: • The HDH desalination system coupling with the waste heat plate LGHC is proposed. • Performance of the desalination system and the plate LGHC is presented. • Influence from the operation pressure on the system performance is investigated. • Gained investment ratio is proposed to characterize the desalination system consumption. - Abstract: Humidification dehumidification (HDH) desalination system is applicable to recover the low grade heat source to heat the seawater before the humidifier. In the paper, plate heat exchangers are integrated to recover the waste heat from the exhaust in the water heated closed air open water (CAOW) HDH desalination system. The performance of the HDH desalination system as well as the plate type of low grade heat collector (LGHC) is investigated at different operation pressures. Gain investment ratio (GIR) is proposed and defined to depict the overall consumption of the whole system. The simulation results show that the modified heat capacity ratio of the dehumidifier (HCRd) is vital for the performance of the HDH desalination system as well as the plate LGHC with a top value of gain output ratio (GOR) at the balance point, HCRd = 1, and the maximum GOR, GOR = 2.44, results from the raised pressure of p = 0.15 MPa. Furthermore, taking the cost for the heat transfer surface area of the LGHC and the air and seawater pipes into consideration, it is revealed that the conditions, HCRd > 1, are more economical due to the increase of GIR, which indicates the profit of unit consumption is more significant.

  4. Direct Heat

    Lienau, P J

    1990-01-01

    Potential resources and applications of earth heat in the form of geothermal energy are large. United States direct uses amount to 2,100 MWt thermal and worldwide 8,850 MWt above a reference temperature of 35 degrees Celsius. Space and district heating are the major direct uses of geothermal energy. Equipment employed in direct use projects is of standard manufacture and includes downhole and circulation pumps, transmission and distribution pipelines, heat exchangers and convectors, heat pumps and chillers. Direct uses of earth heat discussed are space and district heating, greenhouse heating and fish farming, process and industrial applications. The economic feasibility of direct use projects is governed by site specific factors such as location of user and resource, resource quality, system load factor and load density, as well as financing. Examples are presented of district heating in Klamath Falls, and Elko. Further developments of direct uses of geothermal energy will depend on matching user needs to the resource, and improving load factors and load density.

  5. Recovering a hidden polarization by ghost polarimetry.

    Janassek, Patrick; Blumenstein, Sébastien; Elsäßer, Wolfgang

    2018-02-15

    By exploiting polarization correlations of light from a broadband fiber-based amplified spontaneous emission source we succeed in reconstructing a hidden polarization in a ghost polarimetry experiment in close analogy to ghost imaging and ghost spectroscopy. Thereby, an original linear polarization state in the object arm of a Mach-Zehnder interferometer configuration which has been camouflaged by a subsequent depolarizer is recovered by correlating it with light from a reference beam. The variation of a linear polarizer placed inside the reference beam results in a Malus law type second-order intensity correlation with high contrast, thus measuring a ghost polarigram.

  6. Recovering valuable metals from recycled photovoltaic modules.

    Yi, Youn Kyu; Kim, Hyun Soo; Tran, Tam; Hong, Sung Kil; Kim, Myong Jun

    2014-07-01

    Recovering valuable metals such as Si, Ag, Cu, and Al has become a pressing issue as end-of-life photovoltaic modules need to be recycled in the near future to meet legislative requirements in most countries. Of major interest is the recovery and recycling of high-purity silicon (> 99.9%) for the production of wafers and semiconductors. The value of Si in crystalline-type photovoltaic modules is estimated to be -$95/kW at the 2012 metal price. At the current installed capacity of 30 GW/yr, the metal value in the PV modules represents valuable resources that should be recovered in the future. The recycling of end-of-life photovoltaic modules would supply > 88,000 and 207,000 tpa Si by 2040 and 2050, respectively. This represents more than 50% of the required Si for module fabrication. Experimental testwork on crystalline Si modules could recover a > 99.98%-grade Si product by HNO3/NaOH leaching to remove Al, Ag, and Ti and other metal ions from the doped Si. A further pyrometallurgical smelting at 1520 degrees C using CaO-CaF2-SiO2 slag mixture to scavenge the residual metals after acid leaching could finally produce > 99.998%-grade Si. A process based on HNO3/NaOH leaching and subsequent smelting is proposed for recycling Si from rejected or recycled photovoltaic modules. Implications: The photovoltaic industry is considering options of recycling PV modules to recover metals such as Si, Ag, Cu, Al, and others used in the manufacturing of the PV cells. This is to retain its "green" image and to comply with current legislations in several countries. An evaluation of potential resources made available from PV wastes and the technologies used for processing these materials is therefore of significant importance to the industry. Of interest are the costs of processing and the potential revenues gained from recycling, which should determine the viability of economic recycling of PV modules in the future.

  7. Apparatus for recovering oil from Posidonien shale

    1920-04-13

    Equipment for recovering oil from shale and the like, as well as the distilling of coal is characterized in that a number of chambers provided in a known way with upper and lower air supply are arranged open to the receiver of the oil vapors through removable domes which can be attached to the usual oil-vapor carry-off. Arrangement is characterized in that the domes are movable to the side, so that they can be interchangeably attached to the different chambers.

  8. Process for recovering cesium from cesium alum

    Mein, P.G.

    1984-01-01

    Cesium is recovered from cesium alum, CsAl(SO 4 ) 2 , by an aqueous conversion and precipitation reaction using a critical stoichiometric excess of a water-soluble permanganate to form solid cesium permanganate (CsMnO 4 ) free from cesium alum. The other metal salts remain in solution, providing the final pH does not cause hydroxides of aluminium or iron to form. The precipitate is separated from the residual solution to obtain CsMnO 4 of high purity

  9. Recovering an obstacle using integral equations

    Rundell, William

    2009-05-01

    We consider the inverse problem of recovering the shape, location and surface properties of an object where the surrounding medium is both conductive and homogeneous and we measure Cauchy data on an accessible part of the exterior boundary. It is assumed that the physical situation is modelled by harmonic functions and the boundary condition on the obstacle is one of Dirichlet type. The purpose of this paper is to answer some of the questions raised in a recent paper that introduced a nonlinear integral equation approach for the solution of this type of problem.

  10. Long-term storage of recovered krypton

    Horii, Yuji; Yamamoto, Yoshimasa

    1983-01-01

    Various storage methods for krypton-85 recovered from a nuclear fuel reprocessing plant are under development in many countries. These methods include:(1) direct storage in pressurized cylinders, (2) storage of krypton adsorbed on charcoal or zeolite in pressurized cylinders and (3) immobilization (encapsulation) in zeolite. A krypton storage facility using pressurized cylinders has been constructed in the krypton recovery pilot plant in Tokaimura and other methods are now under development. These three methods are evaluated and the features of the constructed facility are also reported. (author)

  11. Recovering the fine structures in solar images

    Karovska, Margarita; Habbal, S. R.; Golub, L.; Deluca, E.; Hudson, Hugh S.

    1994-01-01

    Several examples of the capability of the blind iterative deconvolution (BID) technique to recover the real point spread function, when limited a priori information is available about its characteristics. To demonstrate the potential of image post-processing for probing the fine scale and temporal variability of the solar atmosphere, the BID technique is applied to different samples of solar observations from space. The BID technique was originally proposed for correction of the effects of atmospheric turbulence on optical images. The processed images provide a detailed view of the spatial structure of the solar atmosphere at different heights in regions with different large-scale magnetic field structures.

  12. Five years post whiplash injury: Symptoms and psychological factors in recovered versus non-recovered

    Stålnacke Britt-Marie

    2010-07-01

    Full Text Available Abstract Background Few studies have focused on the differences between persons who are recovered after whiplash injury and those who suffer from persistent disability. The primary aim of this study was therefore to examine differences in symptoms, psychological factors and life satisfaction between subjects classified as recovered and those with persistent disability five years after whiplash injury based on the Neck Disability Index (NDI. Methods A set of questionnaires was answered by 158 persons (75 men, 83 women to assess disability (NDI, pain intensity (VAS, whiplash-related symptoms (Rivermead Post-Concussion Symptoms Questionnaire, RPQ, post-traumatic stress (Impact of Event Scale, IES, depression (Beck's depression inventory, BDI and life satisfaction (LiSat-11. The participants were divided into three groups based on the results of the NDI: recovered (34.8%, mild disability (37.3% and moderate/severe disability (27.3%. Results The moderate/severe group reported significantly higher VAS, BDI and IES scores and lower level of physical health and psychological health compared to the mild and the recovered groups. Less significant differences were reported between the mild and the recovered groups. Conclusions The group with the highest disability score reported most health problems with pain, symptoms, depression, post-traumatic stress and decreased life satisfaction. These findings indicate that classifying these subjects into subgroups based on disability levels makes it possible to optimize the management and treatment after whiplash injury.

  13. Hydrogen isotope recovering and reutilizing method and its device

    Ide, Takahiro.

    1988-01-01

    Purpose: To enable safety and convenient recovery and reutilization of gaseous tritium and other hydrogen isotopes. Constitution: Two kinds of metal hydrides different from each other in the dissociation pressure at an identical temperature are combined, in which a metal hydride of higher dissociation pressure is used for recovery and reutilization for most portion of gaseous hydrogen isotope gases, while the metal hydride of lower dissociation pressure is used for the recovery and reutilization of the remaining gaseous hydrogen isotopes. This enables to extremely lower the concentration of the remaining gaseous hydrogen isotopes, that is, the concentration of tritium in the recoverying system. In addition, since the heating temperature required for releasing the gaseous hydrogen isotopes absorbed in both of the metal hydrides is within such a range as causing no problem for the permeation of the gaseous hydrogen isotopes, there is no requirement for the countermeasure to tritium permeation or the facility for recovering permeated tritium and there is no problem for the material degradation due to the heating at high temperature. (Kawakami, Y.)

  14. PROCESS OF RECOVERING URANIUM FROM ITS ORES

    Galvanek, P. Jr.

    1959-02-24

    A process is presented for recovering uranium from its ores. The crushed ore is mixed with 5 to 10% of sulfuric acid and added water to about 5 to 30% of the weight of the ore. This pugged material is cured for 2 to 3 hours at 100 to 110 deg C and then cooled. The cooled mass is nitrate-conditioned by mixing with a solution equivalent to 35 pounds of ammunium nitrate and 300 pounds of water per ton of ore. The resulting pulp containing 70% or more solids is treated by upflow percolation with a 5% solution of tributyl phosphate in kerosene at a rate equivalent to a residence time of about one hour to extract the solubilized uranium. The uranium is recovered from the pregnant organic liquid by counter-current washing with water. The organic extractant may be recycled. The uranium is removed from the water solution by treating with ammonia to precipitate ammonium diuranate. The filtrate from the last step may be recycled for the nitrate-conditioning treatment.

  15. When will the Antarctic Ozone Hole Recover?

    Newman, Paul A.; Nash, Eric R.; Kawa, S. Randolph; Montzka, Steve

    2006-01-01

    The Antarctic ozone hole develops each year and culminates by early Spring. Antarctic ozone values have been monitored since 1979 using satellite observations from the .TOMS instrument. The severity of the hole has been assessed from TOMS using the minimum total ozone value from the October monthly mean (depth of the hole) and by calculating the average size during the September-October period. Ozone is mainly destroyed by halogen catalytic cycles, and these losses are modulated by temperature variations in the collar of the polar lower stratospheric vortex. In this presentation, we show the relationships of halogens and temperature to, both the size and depth of the hole. Because atmospheric halogen levels are responding to international agreements that limit or phase out production, the amount of halogens in the stratosphere should decrease over the next few decades. Using projections of halogen levels combined with age-of-air estimates, we find that the ozone hole is recovering at an extremely slow rate and that large ozone holes will regularly recur over the next 2 decades. The ozone hole will begin to show first signs of recovery in about 2023, and the hole will fully recover to pre-1980 levels in approximately 2070. This 2070 recovery is 20 years later than recent projections.

  16. A device for locating intercircuit leaks in heat transfer components of WWER steam generators during unit outage

    Matal, O.; Klinga, J.; Holy, F.; Fabian, S.

    1991-01-01

    The device is based on the following principle. The space between the tubes of the cold steam generator is filled with pressurized gas, the spaces of primary collectors in their bottom neck and in the attached tubing are waterproof-closed, and the inner spaces of the heat transfer tubes are gradually filled with modified water. This water is illuminated and its level is monitored. The formation and magnitude of flow and locality of source of gas bubbles leaking into the primary collector space are optically observed and acoustically measured. The device for this includes a module attached to a support, which is slidably located on a column. The module houses a water level indicator, a camera, a light source, and at least one acoustic sensor located under the water level. On the bottom part of the column, along which a water filling hose and a water tubing are led, is suspended an inflatable bag placed into the bottom neck of the primary collector and into the tubing. The water tubing empties in the lowest space, which is formed by the bottom neck of the primary collector and the surface of the inflated bag. On the inflatable bag is located a flange fitted with a light source oriented into the water-filled space of the primary collector, and with safety and attachment valves. (P.A.). 2 figs

  17. Spatially explicit estimation of heat stress-related impacts of climate change on the milk production of dairy cows in the United Kingdom

    Topp, Cairistiona F. E.; Moorby, Jon M.; Pásztor, László; Foyer, Christine H.

    2018-01-01

    Dairy farming is one the most important sectors of United Kingdom (UK) agriculture. It faces major challenges due to climate change, which will have direct impacts on dairy cows as a result of heat stress. In the absence of adaptations, this could potentially lead to considerable milk loss. Using an 11-member climate projection ensemble, as well as an ensemble of 18 milk loss estimation methods, temporal changes in milk production of UK dairy cows were estimated for the 21st century at a 25 km resolution in a spatially-explicit way. While increases in UK temperatures are projected to lead to relatively low average annual milk losses, even for southern UK regions (cow), the ‘hottest’ 25×25 km grid cell in the hottest year in the 2090s, showed an annual milk loss exceeding 1300 kg/cow. This figure represents approximately 17% of the potential milk production of today’s average cow. Despite the potential considerable inter-annual variability of annual milk loss, as well as the large differences between the climate projections, the variety of calculation methods is likely to introduce even greater uncertainty into milk loss estimations. To address this issue, a novel, more biologically-appropriate mechanism of estimating milk loss is proposed that provides more realistic future projections. We conclude that South West England is the region most vulnerable to climate change economically, because it is characterised by a high dairy herd density and therefore potentially high heat stress-related milk loss. In the absence of mitigation measures, estimated heat stress-related annual income loss for this region by the end of this century may reach £13.4M in average years and £33.8M in extreme years. PMID:29738581

  18. Spatially explicit estimation of heat stress-related impacts of climate change on the milk production of dairy cows in the United Kingdom.

    Nándor Fodor

    Full Text Available Dairy farming is one the most important sectors of United Kingdom (UK agriculture. It faces major challenges due to climate change, which will have direct impacts on dairy cows as a result of heat stress. In the absence of adaptations, this could potentially lead to considerable milk loss. Using an 11-member climate projection ensemble, as well as an ensemble of 18 milk loss estimation methods, temporal changes in milk production of UK dairy cows were estimated for the 21st century at a 25 km resolution in a spatially-explicit way. While increases in UK temperatures are projected to lead to relatively low average annual milk losses, even for southern UK regions (<180 kg/cow, the 'hottest' 25×25 km grid cell in the hottest year in the 2090s, showed an annual milk loss exceeding 1300 kg/cow. This figure represents approximately 17% of the potential milk production of today's average cow. Despite the potential considerable inter-annual variability of annual milk loss, as well as the large differences between the climate projections, the variety of calculation methods is likely to introduce even greater uncertainty into milk loss estimations. To address this issue, a novel, more biologically-appropriate mechanism of estimating milk loss is proposed that provides more realistic future projections. We conclude that South West England is the region most vulnerable to climate change economically, because it is characterised by a high dairy herd density and therefore potentially high heat stress-related milk loss. In the absence of mitigation measures, estimated heat stress-related annual income loss for this region by the end of this century may reach £13.4M in average years and £33.8M in extreme years.

  19. Use of an Esophageal Heat Exchanger to Maintain Core Temperature during Burn Excisions and to Attenuate Pyrexia on the Burns Intensive Care Unit

    David Williams

    2016-01-01

    Full Text Available Introduction. Burns patients are vulnerable to hyperthermia due to sepsis and SIRS and to hypothermia due to heat loss during excision surgery. Both states are associated with increased morbidity and mortality. We describe the first use of a novel esophageal heat exchange device in combination with a heater/cooler unit to manage perioperative hypothermia and postoperative pyrexia. Material and Methods. The device was used in three patients with full thickness burns of 51%, 49%, and 45% body surface area to reduce perioperative hypothermia during surgeries of >6 h duration and subsequently to control hyperthermia in one of the patients who developed pyrexia of 40°C on the 22nd postoperative day due to E. coli/Candida septicaemia which was unresponsive to conventional cooling strategies. Results. Perioperative core temperature was maintained at 37°C for all three patients, and it was possible to reduce ambient temperature to 26°C to increase comfort levels for the operating team. The core temperature of the pyrexial patient was reduced to 38.5°C within 2.5 h of instituting the device and maintained around this value thereafter. Conclusion. The device was easy to use with no adverse incidents and helped maintain normothermia in all cases.

  20. Financial analysis on the proposed renewable heat incentive for residential houses in the United Kingdom: A case study on the solar thermal system

    Abu-Bakar, Siti Hawa; Muhammad-Sukki, Firdaus; Ramirez-Iniguez, Roberto; Munir, Abu Bakar; Mohd Yasin, Siti Hajar; Mallick, Tapas Kumar; McLennan, Campbell; Abdul Rahim, Ruzairi

    2014-01-01

    This short communication paper focuses on the renewable heat incentive (RHI) scheme in the United Kingdom (UK); and in particular, on its implication on domestic installations of solar thermal systems (STSs). First, a short review on the STS in the UK is provided. Then, a detailed description of the RHI is discussed. A financial analysis is presented afterwards, analysing the impact of the RHI scheme on the applicants, in terms of the net present value and the internal rate of return. From the financial analysis it has been found that the RHI scheme for domestic installations is only attractive if a longer period of RHI payment, i.e. 17 years, or a higher RHI rate i.e. £0.32 per kW h is implemented. The current proposal from the UK government is not financially viable, and as a result, it may hinder the penetration of domestic solar thermal systems in the residential sector in the UK. - Highlights: • A short review on solar thermal system (STS) is presented. • The renewable heat incentive (RHI) scheme is discussed. • A financial analysis is evaluated under the RHI scheme in the UK. • The analysis indicates the current proposal is not desirable to consumers

  1. Heat and fluid flow in accident of Fukushima Daiichi Nuclear Power Plant, Unit 2. Accident scenario based on thermodynamic model

    Maruyama, Shigenao

    2012-01-01

    An accident scenario of Fukushima Daiichi Nuclear Power Plant, Unit 2 is analyzed from the data open to the public. Phase equilibrium process model was introduced that the vapor and water are at saturation point in the vessels. Proposed accident scenario agrees very well with the data of the plant parameters obtained just after the accident. The estimation describes that the rupture time of the reactor pressure vessel (RPV) was at 22:50 14/3/2011. The estimation shows that the rupture time of the pressure containment vessel (RCP) was at 7:40 15/3/2011. These estimations are different from the ones by TEPCO, however; many measured evidences show good accordance with the present scenario. (author)

  2. Sampling, characterisation and processing of solid recovered fuel production from municipal solid waste: An Italian plant case study.

    Ranieri, Ezio; Ionescu, Gabriela; Fedele, Arcangela; Palmieri, Eleonora; Ranieri, Ada Cristina; Campanaro, Vincenzo

    2017-08-01

    This article presents the classification of solid recovered fuel from the Massafra municipal solid waste treatment plant in Southern Italy in compliancy with the EN 15359 standard. In order to ensure the reproducibility of this study, the characterisation methods of waste input and output flow, the mechanical biological treatment line scheme and its main parameters for each stage of the processing chain are presented in details, together with the research results in terms of mass balance and derived fuel properties. Under this study, only 31% of refused municipal solid waste input stream from mechanical biological line was recovered as solid recovered fuel with a net heating value (NC=HV) average of 15.77 MJ kg -1 ; chlorine content average of 0.06% on a dry basis; median of mercury solid recovered fuel produced meets the European Union standard requirements and can be classified with the class code: Net heating value (3); chlorine (1); mercury (1).

  3. Method of recovering neptunium from spent nuclear fuel

    Tsuboya, T.; N.

    1976-01-01

    An improved Purex wet recovery process including the step of extracting and separating uranium and plutonium simultaneously from the fission products in the presence of nitric acid and nitrous acid by using a multistage extractor unit having an extracting section and a washing section is provided for separating and recovering neptunium simultaneously with uranium and plutonium contained in spent nuclear fuel. The improved method comprises the steps of maintaining the nitrous acid concentration in said extracting section at a level suited for effecting oxidation of neptunium from (V) to (VI) valence, while lowering the nitrous acid concentration in said washing section so as to suppress reduction of neptunium from (VI) to (V) valence, and maintaining the nitric acid concentration in said washing section at a high level

  4. Supervision of the thermal performance of heat exchanger trains

    Negrao, C.O.R.; Tonin, P.C.; Madi, M. [Federal University of Technology Parana UTFPR, Post-graduate Program in Mechanical and Materials Engineering PPGEM, Thermal Science Laboratory LACIT, Av. Sete de Setembro, 3165, CEP 80230-901, Curitiba, Parana (Brazil)

    2007-02-15

    In oil refining, heat exchanger networks are employed to recover heat and therefore save energy of the plant. However, many heat exchangers in crude oil pre-heat trains are under high risk of fouling. Under fouling conditions, the thermal performance of heat exchangers is continuously reduced and its supervision becomes an important task. The large number of heat exchangers in pre-heat trains and the change of operation conditions and feedstock charges make the daily supervision a difficult task. This work applies an approach to follow the performance of heat exchangers [M.A.S. Jeronimo, L.F. Melo, A.S. Braga, P.J.B.F. Ferreira, C. Martins, Monitoring the thermal efficiency of fouled heat exchangers - A simplified method, Experimental Thermal and Fluid Science 14 (1997) 455-463] and extends it to monitor the whole train. The approach is based on the comparison of measured and predicted heat exchanger effectiveness. The measured value is computed from the four inlet and outlet temperatures of a heat exchanger unit. The predicted clean and dirty values of effectiveness are calculated from classical literature relations as a function of NTU and of heat capacity ratio (R). NTU and R are continuously adjusted according to mass flow rate changes. An index of fouling is defined for the whole network and the results show the performance degradation of the network with time. The work also suggests that Jeronimo's index of fouling can be used to estimate the fouling thermal resistance of heat exchangers. (author)

  5. Process of recovering bitumen from shale

    Ryan, H D

    1918-03-26

    A step in the recovery of bitumen from solids which consists in digesting the solids with heavy oil under the action of heat and agitation at a temperature insufficiently high to effect substantial distillation of heavy fractions, but high enough to liquefy heavy hydrocarbons contained in the solids, and then separating solid residual matter, substantially as described.

  6. Energy consumption analysis and simulation of waste heat recovery technology of ceramic rotary kiln

    Chen, Zhiguang; Zhou, Yu; Qin, Chaokui; Zhang, Xuemei

    2018-03-01

    Ceramsite is widely used in the construction industry, insulation works and oil industry in China, and the manufacture equipment is mainly industrial kiln. In this paper, energy consumption analysis had been carried out through experimental test of a Ceramsite kiln in Henan province. Results showed that the discharge temperature of Ceramsite was about 1393K, and the waste heat accounted for 22.1% of the total energy consumption. A structure of cyclone preheater which recovered waste heat of the high temperature Ceramsite by blast cooling was designed. Then, using Fluent software, performance of the unit was simulated. The minimum temperature that Ceramsite could reach, heat dissipating capacity of Ceramsite, temperature at air outlet, wall temperature of the unit and pressure loss were analyzed. Performance of the designed unit under different inlet velocity was analyzed as well.

  7. Process for recovering cesium from cesium alum

    Mein, P.G.

    1984-01-01

    Cesium is recovered from cesium alum, CsAl(SO 4 ) 2 , by a two-reaction sequence in which the cesium alum is first dissolved in an aqueous hydroxide solution to form cesium alum hydroxide, CsAl(OH) 3 , and potassium sulfate, K 2 SO 4 . Part of the K 2 SO 4 precipitates and is separated from the supernatant solution. In the second reaction, a water-soluble permanganate, such as potassium permanganate, KMnO 4 , is added to the supernatant. This reaction forms a precipitate of cesium permanganate, CsMnO 4 . This precipitate may be separated from the residual solution to obtain cesium permanganate of high purity, which can be sold as a product or converted into other cesium compounds

  8. Process for recovering cesium from pollucite

    Mein, P.G.

    1985-01-01

    Cesium is recovered from a cesium-bearing mineral such as pollucite by extraction with hydrochloric acid to obtain an extract of cesium chloride and other alkali metal and polyvalent metal chlorides. The iron and aluminum chlorides can be precipitated as the hydroxides and separated from the solution of the alkali metal chlorides to which is added potassium permanganate or other water-soluble permanganate to selectively precipitate cesium permanganate. The cesium precipitate is then separated from the residual solution containing the metal chlorides. The cesium permanganate, which is in a very pure form, can be converted to other cesium compounds by reaction with a reducing agent to obtain cesium carbonate and cesium delta manganese dioxide

  9. Heat Roadmap Europe

    Connolly, David; Mathiesen, Brian Vad; Lund, Henrik

    2015-01-01

    This document is a summary of the key technical inputs for the modelling of the heat strategy for Europe outlined in the latest Heat Roadmap Europe studies [1, 2]. These studies quantify the impact of alternative heating strategies for Europe in 2030 and 2050. The study is based on geographical...... information systems (GIS) and energy system analyses. In this report, the inputs for other modelling tools such as PRIMES are presented, in order to enable other researches to generate similar heating scenarios for Europe. Although Heat Roadmap Europe presents a complete heat strategy for Europe, which...... includes energy efficiency, individual heating units (such as boilers and heat pumps), and heat networks, the recommendations here are primarily relating to the potential and modelling of district heating. Although other solutions will play a significant role in decarbonising the heating and cooling sector...

  10. Power generation from residual industrial heat

    Nguyen, T.Q.; Slawnwhite, J.D.; Boulama, K.Goni

    2010-01-01

    Industrial plants continuously reject large amounts of thermal energy through warm liquid or gaseous effluents during normal operation. These energy losses contribute to an inflation of production costs and also threaten the environment. This paper investigates methods of recovering the residual low grade thermal energy and converting it into higher quality mechanical energy using the thermodynamic Rankine cycle principle. For the temperature range of the available thermal energy, water was shown to be a poor working fluid for the conversion system, thus several potential working fluids, including ammonia, synthetic refrigerants, and organic compounds have been considered as alternatives. A comparative analysis led to the identification of different performance evaluation criteria. For example, the water-based Rankine cycle and, to a lesser extent, the ammonia-based Rankine cycle proved to be interesting when the power generation potential per unit working fluid mass flow rate was considered. On the other hand, Rankine-like cycles using dry hydrocarbon working fluids proved much more interesting in terms of energy conversion efficiency, as well as in terms of the net mechanical power generation potential for a given heat source. All performance indicators were low at low temperatures, and improved as the primary heat source was available at higher temperatures. This paper also discusses the influence of various external and internal operating parameters, such as heat source and heat sink temperatures, turbine and pump isentropic efficiencies and the addition of an internal heat exchanger on the overall performance of the energy recovery and conversion system.

  11. Swedish recovered wood waste: linking regulation and contamination.

    Krook, J; Mårtensson, A; Eklund, M; Libiseller, C

    2008-01-01

    In Sweden, large amounts of wood waste are generated annually from construction and demolition activities, but also from other discarded products such as packaging and furniture. A large share of this waste is today recovered and used for heat production. However, previous research has found that recovered wood waste (RWW) contains hazardous substances, which has significant implications for the environmental performance of recycling. Improved sorting is often suggested as a proper strategy to decrease such implications. In this study, we aim to analyse the impacts of waste regulation on the contamination of RWW. The occurrence of industrial preservative-treated wood, which contains several hazardous substances, was used as an indicator for contamination. First the management of RWW during 1995-2004 was studied through interviews with involved actors. We then determined the occurrence of industrial preservative-treated wood in RWW for that time period for each supplier (actor). From the results, it can be concluded that a substantially less contaminated RWW today relies on extensive source separation. The good news is that some actors, despite several obstacles for such upstream efforts, have already today proved capable of achieving relatively efficient separation. In most cases, however, the existing waste regulation has not succeeded in establishing strong enough incentives for less contaminated waste in general, nor for extensive source separation in particular. One important factor for this outcome is that the current market forces encourage involved actors to practice weak quality requirements and to rely on end-of-pipe solutions, rather than put pressure for improvements on upstream actors. Another important reason is that there is a lack of communication and oversight of existing waste regulations. Without such steering mechanisms, the inherent pressure from regulations becomes neutralized.

  12. The surface urban heat island response to urban expansion: A panel analysis for the conterminous United States

    Li, Xiaoma; Zhou, Yuyu; Asrar, Ghassem R.; Imhoff, Marc; Li, Xuecao

    2017-12-01

    Abstract: Urban heat island (UHI), a major concern worldwide, affects human health and energy use. With current and anticipated rapid urbanization, improved understanding of the response of UHI to urbanization is important for impact analysis and developing effective adaptation measures and mitigation strategies. Current studies mainly focus on a single or a few big cities and knowledge on the response of UHI to urbanization for large areas is very limited. Modelling UHI caused by urbanization for large areas that encompass multiple metropolitans remains a major scientific challenge/opportunity. As a major indicator of urbanization, urban area size lends itself well for representation in prognostic models to investigate the impacts of urbanization on UHI and the related socioeconomic and environmental effects. However, we have little knowledge on how UHI responds to the increase of urban area size, namely urban expansion, and its spatial and temporal variation over large areas. In this study, we investigated the relationship between surface UHI (SUHI) and urban area size in the climate and ecological context, and its spatial and temporal variations, based on a panel analysis of about 5000 urban areas of 10 km2 or larger, in the conterminous U.S. We found statistically significant positive relationship between SUHI and urban area size, and doubling the urban area size led to a SUHI increase of higher than 0.7 °C. The response of SUHI to the increase of urban area size shows spatial and temporal variations, with stronger SUHI increase in the Northern region of U.S., and during daytime and summer. Urban area size alone can explain as much as 87% of the variance of SUHI among cities studied, but with large spatial and temporal variations. Urban area size shows higher association with SUHI in regions where the thermal characteristics of land cover surrounding the urban are more homogeneous, such as in Eastern U.S., and in the summer months. This study provides a

  13. Numerical investigation of the energy performance of an Opaque Ventilated Façade system employing a smart modular heat recovery unit and a latent heat thermal energy system

    Diallo, Thierno M.O.; Zhao, Xudong; Dugue, Antoine; Bonnamy, Paul; Javier Miguel, Francisco; Martinez, Asier; Theodosiou, Theodoros; Liu, Jing-Sheng; Brown, Nathan

    2017-01-01

    Highlights: •An innovative E2VENT ventilated façade system is presented and modelled with TRNSYS. •The energy efficiency of the system is assessed for five climates in Europe. •The E2VENT retrofitting system is compared with a traditional retrofit method. •The E2VENT system achieves 16.5–23.5% primary energy saving. •The E2VENT system saves twice as much primary energy as the traditional retrofit. -- Abstract: The building sector is responsible for more than 40% of the EU’s total energy consumption. To reduce the energy consumption in buildings and to achieve the EU’s fossil fuel saving targets for 2020 and beyond 2050, the energy efficient retrofitting strategies are critically important and need to be implemented effectively. This paper presents a dynamic numerical investigation of the energy performance of an innovative façade integrate-able energy efficient ventilation system (E2VENT) that incorporates a smart modular heat recovery unit (SMHRU) and a latent heat thermal energy system (LHTES). A number of component simulation models, including SMHRU, LHTES, Cladding and Building Energy Management System (BEMS), were developed and then integrated using the TRNSYS software which is an advanced building energy performance simulation tool. On this basis, sizing, optimisation and characterisation of the system elements including the HVAC system and insulation layer thickness were carried out. The overall energy efficiency of the E2VENT system and its impact on the energy performance of a post-retrofit building were then investigated. In particular, the heating and cooling energy performance of the E2VENT façade module was numerically studied at five different climatic conditions in Europe. Furthermore, the innovative E2VENT retrofitting was compared with traditional retrofittings in terms of the energy efficiency and primary energy savings. It was found that the innovative E2VENT solution can achieve 16.5–23.5% building primary energy saving and

  14. Microwave processing heats up

    Microwaves are a common appliance in many households. In the United States microwave heating is the third most popular domestic heating method food foods. Microwave heating is also a commercial food processing technology that has been applied for cooking, drying, and tempering foods. It's use in ...

  15. High-efficiency heat pump technology using metal hydrides (eco-energy city project)

    Morita, Y.; Harada, T.; Niikura, J.; Yamamoto, Y.; Suzuki, J. [Human Environmental Systems Development Center, Matsushita Electric Industrial Co., Ltd., Moriguchi, Osaka (Japan); Gamo, T. [Corporate Environmental Affairs Div., Matsushita Electric Industrial Co., Ltd., Kadoma, Osaka (Japan)

    1999-07-01

    Metal hybrides are effective materials for utilizing hydrogen as a clean energy medium. That is, when the metal hydrides absorb or desorb the hydrogen, a large heat output of reaction occurs. So, the metal hydrides can be applied to a heat pump. We have researched on a high efficiency heat pump technology using their metal hydrides. In this report, a double effect type metal hydride heat pump configuration is described in which the waste heat of 160 C is recovered in a factory cite and transported to areas far distant from the industrial district. In the heat recovery unit, a low pressure hydrogen is converted into highly effective high pressure hydrogen by applying the metal hydrides. Other metal hydrides perform the parts of heating by absorbing the hydrogen and cooling by desorbing the hydrogen in the heat supply unit. One unit scale of the system is 3 kW class as the sum of heating and cooling. This system using the hydrogen absorbing alloy also has good energy storage characteristics and ambient hydrogen pressure self-safety control ability. Furthermore, this heating and cooling heat supply system is not harmful to the natural environment because it is a chlorofluorocarbon-free, and low noise type system. We have developed in the following element technologies to attain the above purposes, that is development of hydrogen absorbing alloys with high heat outputs and technologies to construct the heat pump system. This study is proceeded at present as one of the programs in New Sunshine Project, which aims for development of ingenious energy utilization technology to achieve reduction of primary energy consumption with keeping cultural and wealthy life and preventing deterioration of global environment. (orig.)

  16. Heat recovery optimization in a steam-assisted gravity drainage (SAGD) plant

    Ashrafi, Omid; Navarri, Philippe; Hughes, Robin; Lu, Dennis

    2016-01-01

    Pinch Analysis was used to improve the energy performance of a typical steam-assisted gravity drainage (SAGD) process. The objective of this work was to reduce the amount of natural gas used for steam generation in the plant and the associated greenhouse gas emissions. The INTEGRATION software was used to analyze how heat is being used in the existing design and identify inefficient heat exchanges causing excessive use of energy. Several modifications to improve the base case heat exchanger network (HEN) were identified. The proposed retrofit projects reduced the process heating demands by improving the existing heat recovery system and by recovering waste heat and decreased natural gas consumption in the steam production unit by approximately 40 MW, representing approximately 8% of total consumption. As a result, the amount of glycol used to transfer energy across the facility was also reduced, as well as the electricity consumption related to glycol pumping. It was shown that the proposed heat recovery projects reduced natural gas costs by C$3.8 million/y and greenhouse gas emissions by 61,700 t/y of CO_2. - Highlights: • A heat integration study using Pinch analysis was performed in a SAGD process. • Several modifications are suggested to improve the existing heat recovery system. • Heat recovery projects increased boiler feed water and combustion air temperatures. • The proposed modifications reduced natural gas use for steam generation. • Heat recovery significantly reduced operating costs and greenhouse gas emissions.

  17. Self-Recovering Sensor-Actor Networks

    Maryam Kamali

    2010-07-01

    Full Text Available Wireless sensor-actor networks are a recent development of wireless networks where both ordinary sensor nodes and more sophisticated and powerful nodes, called actors, are present. In this paper we formalize a recently introduced algorithm that recovers failed actor communication links via the existing sensor infrastructure. We prove via refinement that the recovery is terminating in a finite number of steps and is distributed, thus self-performed by the actors. Most importantly, we prove that the recovery can be done at different levels, via different types of links, such as direct actor links or indirect links between the actors, in the latter case reusing the wireless infrastructure of sensors. This leads to identifying coordination classes, e.g., for delegating the most security sensitive coordination to the direct actor-actor coordination links, the least real-time constrained coordination to indirect links, and the safety critical coordination to both direct actor links and indirect sensor paths between actors. Our formalization is done using the theorem prover in the RODIN platform.

  18. Method for chromatographically recovering scandium and yttrium

    Snyder, T.S.; Stoltz, R.A.

    1991-01-01

    This paper describes a method for chromatographically recovering scandium and yttrium from the residue of a sand chlorinator. It comprises: providing a residue from a sand chlorinator, the residue containing scandium, yttrium, sodium, calcium and at least one radioactive metal of the group consisting of radium, thorium and uranium; digesting the residue with an acid to produce an aqueous liquid containing scandium, yttrium, sodium, calcium and at least one radioactive metal of the group consisting of radium, thorium and uranium; feeding the metal containing liquid through a cation exchanger; eluding the cation exchanger with an acid eluant to to produce: a first eluate containing at least half of the total weight of the calcium and sodium in the feed liquid; a second eluate containing at least half of the total weight of the one or more radioactive metals in the feed liquid; a third eluate containing at least half of the yttrium in the feed liquid, and a fourth eluate containing at least half of the weight of the scandium in the feed liquid

  19. Small Sized Drone Fall Recover Mechanism Design

    LIU, Tzu-Heng; CHAO, Fang-Lin; LIOU, Jhen-Yuan

    2017-12-01

    Drones uses four motors to rotate clockwise, counter-clockwise, or change in rotational speed to change its status of motion. The problem of Unmanned Aerial Vehicle turnover causes personal loses and harm local environment. Designs of devices that can let falling drones recover are discussed. The models attempt to change the orientation, so that the drone may be able to improve to the point where it can take off again. The design flow included looking for functional elements, using simplify model to estimate primary functional characteristics, and find the appropriate design parameters. For reducing the complexity, we adopted the simple rotate mechanism with rotating arms to change the fuselage angle and reduce the dependence on the extra-components. A rough model was built to verify structure, and then the concept drawing and prototype were constructed. We made the prototype through the integration of mechanical part and the electronic control circuit. The electronic control module that selected is Arduino-mini pro. Through the Bluetooth modules, user can start the rebound mechanism by the motor control signal. Protections frames are added around each propeller to improve the body rotate problem. Limited by current size of Arduino module, motor and rebound mechanism make the main chassis more massive than the commercial product. However, built-in sensor and circuit miniaturization will improve it in future.

  20. Reward banding to determine reporting rate of recovered mourning dove bands

    Tomlinson, R.E.

    1968-01-01

    Reward bands placed on the other leg of certain regularly banded immature mourning doves (Zenaidura macroura) were used to develop information on reporting rates of recovered dove bands. Reports from 15 widely separated sections of the United States showed considerable variation in recovery rate of doves both with and without reward bands. The overall percentages of banded doves that were reported as recovered were 9.69% for those with reward bands and 3.83% for controls. The bandreporting rate for states influenced by publicity was 66%; that for states not influenced was 32%.

  1. Utilising heat from nuclear waste for space heating

    Deacon, D.

    1982-01-01

    A heating unit utilising the decay heat from irradiated material comprises a storage envelope for the material associated with a heat exchange system, means for producing a flow of air over the heat exchange system to extract heat from the material, an exhaust duct capable of discharging the heated air to the atmosphere, and means for selectively diverting at least some of the heated air to effect the required heating. With the flow of air over the heat exchange system taking place by a natural thermosyphon process the arrangement is self regulating and inherently reliable. (author)

  2. Techno-economic evaluation of a ventilation system assisted with exhaust air heat recovery, electrical heater and solar energy

    Özyoğurtçu, Gamze; Mobedi, Moghtada; Özerdem, Barış

    2014-01-01

    The energy consumed to condition fresh air is considerable, particularly for the buildings such as cinema, theatre or gymnasium saloons. The aim of the present study is to design a ventilation system assisted with exhaust air heat recovery unit, electrical heater and stored solar energy, then to make an economical analysis based on life cycle cost (LCC) to find out its payback period. The system is able to recover thermal energy of exhaust air, store solar energy during the sunlight period an...

  3. Plate heat exchangers in air conditioning applications. Development of air-coolers, air-heaters and air-conditioning units with low pressure loss. Plattenwaermetauscher in raumlufttechnischen Anlagen. Entwicklung stroemungsoptimierter Luftkuehler, Lufterhitzer und Klimageraete

    Bach, H; Diemer, R; Eisenmann, G; Goettling, D; Madjidi, M

    1989-08-01

    To prepare the development of a water to air plate heat exchanger the state of the art, i.e. the technological knowhow and the design basis are given. The concept and ideas are presented which lead to a slightly wavy plate. Furthermore an exemplary design of a plate heat exchanger and an air-conditioning unit is described and finally the application of plate heat exchangers as direct evaporators and the potential icing problems are investigated. Comparing measured and calculated data shows that the performance of plates with plane surfaces can be predicted fairly well by the presented design methods. The performance of plates with strongly wavy surface however has to be measured. Optimization calculations yield to an air gap of slightly over 4 mm. Comparison with an air-conditioning unit demonstrates that the strongest advantage is for the air cooler (one third of the pressure loss) that a new concept of an air-conditioning unit has lower losses in the fan unit and that it does not need an eliminator. This results in half the volume for the new unit, in a pressure drop of 88%, fan power of 90% and fan revolutions of 50%. (orig./GL).

  4. Optimal usage of low temperature heat sources to supply district heating by heat pumps

    Pieper, Henrik; Ommen, Torben Schmidt; Markussen, Wiebke Brix

    2017-01-01

    This paper presents a theoretical study on the optimal usage of different low temperature heat sources to supply district heating by heat pumps. The study is based on data for the Copenhagen region. The heat sources were prioritized based on the coefficient of performance calculated for each hour...... and the covered demand of each heat source as well as required peak unit capacity. The results showed that heat pumps using different heat sources yield better performance than a heat pump based on a single one. The performance was influenced by the composition of the different heat sources. It was found that 78......% groundwater, 22% seawater and 0% air resulted in highest COP of 3.33 for the given heat demand. Furthermore, the implementation of rule based short term storage made peak units redundant. The variation in base load capacity showed that heat pumps utilizing the analyzed heat sources could perform very...

  5. Heat and power from combustibles

    Zogg, M.

    2002-01-01

    This article compares four ways of generating heat and power from liquid and gaseous fuels. Various combinations of conventional boilers, heat pumps, combined heat and power units and combined-cycle power plants are considered and the ratio of heat to electrical power produced is discussed. Fuel requirements for the four combinations are looked at and net emissions of carbon dioxide, oxides of nitrogen and carbon monoxide presented in graphical form. The author makes recommendations on the choice of the technology to be used to generate heat and electricity for different heat/power ratios and criticises the all too slack emission limits for small combined heat and power units

  6. Nuclear Security Summit and Workshop 2015: Preventing, Understanding and Recovering from Nuclear Accidents lessons learned from Chernobyl and Fukushima

    2016-09-01

    Workshop 2015 "Preventing, Understanding and Recovering from Nuclear Accidents"--lessons learned from Chernobyl and Fukushima Distribution Statement...by the factor to get the U.S. customary unit. “Preventing, Understanding and Recovering from Nuclear Accidents” – lessons learned from Chernobyl ...and Fukushima NUCLEAR SECURITY SUMMIT & WORKSHOP 2015 2 Background The 1986 Chernobyl and the 2011 Fukushima accidents provoked world-wide concern

  7. Waste heat and water recovery opportunities in California tomato paste processing

    Amón, Ricardo; Maulhardt, Mike; Wong, Tony; Kazama, Don; Simmons, Christopher W.

    2015-01-01

    Water and energy efficiency are important for the vitality of the food processing industry as demand for these limited resources continues to increase. Tomato processing, which is dominated by paste production, is a major industry in California – where the majority of tomatoes are processed in the United States. Paste processing generates large amounts of condensate as moisture is removed from the fruit. Recovery of the waste heat in this condensate and reuse of the water may provide avenues to decrease net energy and water use at processing facilities. However, new processing methods are needed to create demand for the condensate waste heat. In this study, the potential to recover condensate waste heat and apply it to the tomato enzyme thermal inactivation processing step (the hot break) is assessed as a novel application. A modeling framework is established to predict heat transfer to tomatoes during the hot break. Heat recovery and reuse of the condensate water are related to energy and monetary savings gained through decreased use of steam, groundwater pumping, cooling towers, and wastewater processing. This analysis is informed by water and energy usage data from relevant unit operations at a commercial paste production facility. The case study indicates potential facility seasonal energy and monetary savings of 7.3 GWh and $166,000, respectively, with most savings gained through reduced natural gas use. The sensitivity of heat recovery to various process variables associated with heat exchanger design and processing conditions is presented to identify factors that affect waste heat recovery. - Highlights: • The potential to recovery waste heat in tomato paste processing is examined. • Heat transfer from evaporator condensate to tomatoes in the hot break is modeled. • Processing facility data is used in model to predict heat recovery energy savings. • The primary benefit of heat recovery is reduced use of natural gas in boilers. • Reusing

  8. Collector for recovering gallium from weapons plutonium

    Philip, C.V.; Anthony, R.G.; Chokkaram, S.

    1998-09-01

    Currently, the separation of gallium from weapons plutonium involves the use of aqueous processing using either solvent extraction of ion exchange. However, this process generates significant quantities of liquid radioactive wastes. A Thermally Induced Gallium Removal process, or TIGR, developed by researchers at Los Alamos National Laboratories, is a simpler alternative to aqueous processing. This research examined this process, and the behavior of gallium suboxide, a vapor that is swept away by passing hydrogen/argon over gallium trioxide/plutonium oxide heated at 1100 C during the TIGR process. Through experimental procedures, efforts were made to prevent the deposition of corrosive gallium onto furnace and vent surfaces. Experimental procedures included three options for gallium removal and collection: (1) collection of gallium suboxide through use of a cold finger; (2) collection by in situ air oxidation; and (3) collection of gallium on copper. Results conclude all three collection mechanisms are feasible. In addition, gallium trioxide exists in three crystalline forms, and each form was encountered during each experiment, and that each form will have a different reactivity

  9. Pentachlorophenol (PCP) sludge recycling unit

    1994-08-01

    The Guelph Utility Pole Company treats utility poles by immersion in pentachlorophenol (PCP) or by pressure treatment with chromated copper arsenate (CCA). The PCP treatment process involves a number of steps, each producing a certain amount of sludge and other wastes. In a plant upgrading program to improve processing and treatment of poles and to reduce and recycle waste, a PCP recovery unit was developed, first as an experimental pilot-scale unit and then as a full-scale unit. The PCP recovery unit is modular in design and can be modified to suit different requirements. In a recycling operation, the sludge is pumped through a preheat system (preheated by waste heat) and suspended solids are removed by a strainer. The sludge is then heated in a tank and at a predetermined temperature it begins to separate into its component parts: oil, steam, and solids. The steam condenses to water containing low amounts of light oil, and this water is pumped through an oil/water separator. The recovered oil is reused in the wood treatment process and the water is used in the CCA plant. The oil remaining in the tank is reused in PCP treatment and the solid waste, which includes small stones and wood particles, is removed and stored. By the third quarter of operation, the recovery unit was operating as designed, processing ca 10,000 gal of sludge. This sludge yielded 6,500 gal of water, 3,500 gal of oil, and ca 30 gal of solids. Introduction of the PCP sludge recycling system has eliminated long-term storage of PCP sludge and minimized costs of hazardous waste disposal. 4 figs

  10. Evaluation of the potential of different high calorific waste fractions for the preparation of solid recovered fuels.

    Garcés, Diego; Díaz, Eva; Sastre, Herminio; Ordóñez, Salvador; González-LaFuente, José Manuel

    2016-01-01

    Solid recovered fuels constitute a valuable alternative for the management of those non-hazardous waste fractions that cannot be recycled. The main purpose of this research is to assess the suitability of three different wastes from the landfill of the local waste management company (COGERSA), to be used as solid recovered fuels in a cement kiln near their facilities. The wastes analyzed were: End of life vehicles waste, packaging and bulky wastes. The study was carried out in two different periods of the year: November 2013 and April 2014. In order to characterize and classify these wastes as solid recovered fuels, they were separated into homogeneous fractions in order to determine different element components, such as plastics, cellulosic materials, packagings or textile compounds, and the elemental analysis (including chlorine content), heavy metal content and the heating value of each fraction were determined. The lower heating value of the waste fractions on wet basis varies between 10 MJ kg(-1) and 42 MJ kg(-1). One of the packaging wastes presents a very high chlorine content (6.3 wt.%) due to the presence of polyvinylchloride from pipe fragments, being the other wastes below the established limits. Most of the wastes analyzed meet the heavy metals restrictions, except the fine fraction of the end of life vehicles waste. In addition, none of the wastes exceed the mercury limit content, which is one of the parameters considered for the solid recovered fuels classification. A comparison among the experimental higher heating values and empirical models that predict the heating value from the elemental analysis data was carried out. Finally, from the three wastes measured, the fine fraction of the end of life vehicles waste was discarded for its use as solid recovered fuels due to the lower heating value and its high heavy metals content. From the point of view of the heating value, the end of life vehicles waste was the most suitable residue with a lower

  11. NOx generation method from recovered nitric acid by electrolysis

    Suzuki, Y.; Shimizu, H.; Inoue, M.; Fujiso, M.; Shibuya, M.; Iwamoto, F.; Outou, Y.; Ochi, E.; Tsuyuki, T.

    1998-01-01

    An R and D has been conducted on an electrolytic NO x generation process utilizing recovered nitric acid from a PUREX reprocessing plant. The purpose of the study is to drastically reduce the amount of low-level-liquid waste(LLW). The research program phase-1, constituting mainly of electrochemical reaction mechanism study, material balance evaluation and process design study, finished in 1995. The results were presented in the previous papers). The research program phase-2 has started in 1995. The schedule is as follows: FY 1991-1994: Research program phase-1 Basic study using electrolysis equipment with 100-700 cm 2 electrodes FY 1995-1999: Research program phase-2 Process performance test by larger scale electrolysis equipment with 3.6 m 2 electrodes - pilot plant design (FY 1995) - pilot plant construction (FY 1996) - engineering data acquisition (FY 1997-1999). The process consists of many unit operations such as electrolysis, oxidation, nitric acid concentration, NO x compression and storage, NO x recovery, off-gas treatment and acid supplier. This paper outlines the pilot test plant. (author)

  12. Industrial excess heat for district heating in Denmark

    Bühler, Fabian; Petrović, Stefan; Karlsson, Kenneth; Elmegaard, Brian

    2017-01-01

    Highlights: •Method for utilisation potential of industrial excess heat for district heating. •Industrial excess heat from thermal processes is quantified at single production units. •Linking of industrial excess heat sources and district heating demands done in GIS. •Excess heat recovery using direct heat transfer and heat pumps. •5.1% of the Danish district heating demand could be supplied by industrial excess heat. -- Abstract: Excess heat is available from various sources and its utilisation could reduce the primary energy use. The accessibility of this heat is however dependent amongst others on the source and sink temperature, amount and potential users in its vicinity. In this work a new method is developed which analyses excess heat sources from the industrial sector and how they could be used for district heating. This method first allocates excess heat to single production units by introducing and validating a new approach. Spatial analysis of the heat sources and consumers are then performed to evaluate the potential for using them for district heating. In this way the theoretical potential of using the excess heat for covering the heating demand of buildings is determined. Through the use of industry specific temperature profiles the heat usable directly or via heat pumps is further found. A sensitivity analysis investigates the impact of future energy efficiency measures in the industry, buildings and the district heating grid on the national potential. The results show that for the case study of Denmark, 1.36 TWh of district heat could be provided annually with industrial excess heat from thermal processes which equals 5.1% of the current demand. More than half of this heat was found to be usable directly, without the need for a heat pump.

  13. Heat Recovery Ventilation for Housing: Air-to-Air Heat Exchangers.

    Corbett, Robert J.; Miller, Barbara

    The air-to-air heat exchanger (a fan powered ventilation device that recovers heat from stale outgoing air) is explained in this six-part publication. Topic areas addressed are: (1) the nature of air-to-air heat exchangers and how they work; (2) choosing and sizing the system; (3) installation, control, and maintenance of the system; (4) heat…

  14. Effect of enhanced ultraviolet germicidal irradiation in the heating ventilation and air conditioning system on ventilator-associated pneumonia in a neonatal intensive care unit.

    Ryan, R M; Wilding, G E; Wynn, R J; Welliver, R C; Holm, B A; Leach, C L

    2011-09-01

    The objective of this study was to test the hypothesis that enhanced ultraviolet germicidal irradiation (eUVGI) installed in our neonatal intensive care unit (NICU) heating ventilation and air conditioning system (HVAC) would decrease HVAC and NICU environment microbes, tracheal colonization and ventilator-associated pneumonia (VAP). The study was designed as a prospective interventional pre- and post-single-center study. University-affiliated Regional Perinatal Center NICU. Intubated patients in the NICU were evaluated for colonization, and a high-risk sub-population of infants <30 weeks gestation ventilated for ≥ 14 days was studied for VAP. eUVGI was installed in the NICU's remote HVACs. The HVACs, NICU environment and intubated patients' tracheas were cultured pre- and post-eUVGI for 12 months. The high-risk patients were studied for VAP (positive bacterial tracheal culture, increased ventilator support, worsening chest radiograph and ≥ 7 days of antibiotics). Pseudomonas, Klebsiella, Serratia, Acinetobacter, Staphylococcus aureus and Coagulase-negative Staphylococcus species were cultured from all sites. eUVGI significantly decreased HVAC organisms (baseline 500,000 CFU cm(-2); P=0.015) and NICU environmental microbes (P<0.0001). Tracheal microbial loads decreased 45% (P=0.004), and fewer patients became colonized. VAP in the high-risk cohort fell from 74% (n=31) to 39% (n=18), P=0.04. VAP episodes per patient decreased (Control: 1.2 to eUVGI: 0.4; P=0.004), and antibiotic usage was 62% less (P=0.013). eUVGI decreased HVAC microbial colonization and was associated with reduced NICU environment and tracheal microbial colonization. Significant reductions in VAP and antibiotic use were also associated with eUVGI in this single-center study. Large randomized multicenter trials are needed.

  15. Heat exchanger

    Harada, F; Yanagida, T; Fujie, K; Futawatari, H

    1975-04-30

    The purpose of this construction is the improvement of heat transfer in finned tube heat exchangers, and therefore the improvement of its efficiency or its output per unit volume. This is achieved by preventing the formation of flow boundary layers in gaseous fluid. This effect always occurs on flow of smooth adjacent laminae, and especially if these have pipes carrying liquid passing through them; it worsens the heat transfer of such a boundary layer considerably compared to that in the turbulent range. The fins, which have several rows of heat exchange tubes passing through them, are fixed at a small spacing on theses tubes. The fins have slots cut in them by pressing or punching, where the pressed-out material remains as a web, which runs parallel to the level of the fin and at a small distance from it. These webs and slots are arranged radially around every tube hole, e.g. 6 in number. For a suitable small tube spacing, two adjacent tubes opposite each other have one common slot. Many variants of such slot arrangements are illustrated.

  16. The health effects of hotter summers and heat waves in the population of the United Kingdom: a review of the evidence.

    Arbuthnott, Katherine G; Hajat, Shakoor

    2017-12-05

    It is widely acknowledged that the climate is warming globally and within the UK. In this paper, studies which assess the direct impact of current increased temperatures and heat-waves on health and those which project future health impacts of heat under different climate change scenarios in the UK are reviewed.This review finds that all UK studies demonstrate an increase in heat-related mortality occurring at temperatures above threshold values, with respiratory deaths being more sensitive to heat than deaths from cardiovascular disease (although the burden from cardiovascular deaths is greater in absolute terms). The relationship between heat and other health outcomes such as hospital admissions, myocardial infarctions and birth outcomes is less consistent. We highlight the main populations who are vulnerable to heat. Within the UK, these are older populations, those with certain co-morbidities and those living in Greater London, the South East and Eastern regions.In all assessments of heat-related impacts using different climate change scenarios, deaths are expected to increase due to hotter temperatures, with some studies demonstrating that an increase in the elderly population will also amplify burdens. However, key gaps in knowledge are found in relation to how urbanisation and population adaptation to heat will affect health impacts, and in relation to current and future strategies for effective, sustainable and equitable adaptation to heat. These and other key gaps in knowledge, both in terms of research needs and knowledge required to make sound public- health policy, are discussed.

  17. Heat pumps: heat recovery

    Pielke, R

    1976-01-01

    The author firstly explains in a general manner the functioning of the heat pump. Following a brief look at the future heat demand and the possibilities of covering it, the various methods of obtaining energy (making use of solar energy, ground heat, and others) and the practical applications (office heating, swimming pool heating etc.) are explained. The author still sees considerable difficulties in using the heat pump at present on a large scale. Firstly there is not enough maintenance personnel available, secondly the electricity supply undertakings cannot provide the necessary electricity on a wide basis without considerable investments. Other possibilities to save energy or to use waste energy are at present easier and more economical to realize. Recuperative and regenerative systems are described.

  18. Agglomeration and Deposition Behaviour of Solid Recovered Fuel

    Pedersen, Morten Nedergaard; Jensen, Peter Arendt; Nielsen, Mads

    2015-01-01

    Waste derived fuels such as Solid Recovered Fuel (SRF) are increasingly being used in the cement industry as a means to reduce cost [1]. SRF is produced by separating the combustible fraction from industrial or municipal solid waste (MSW). The recovered fraction has a higher content of combustibl...

  19. 33 CFR 385.20 - Restoration Coordination and Verification (RECOVER).

    2010-07-01

    ... applying system-wide models and tools; and evaluating modifications to the Plan. RECOVER is not a policy... accordance with § 385.31, RECOVER shall conduct credible scientific assessments of hydrological, water... available science and that the results are provided for external peer review, as appropriate, and are made...

  20. On the recovering of a coupled nonlinear Schroedinger potential

    Corona, Gulmaro Corona [Area de Analisis Matematico y sus Aplicaciones, Universidad Autonoma Metropolitana, Atzcapotzalco, DF (Mexico)]. E-mail: ccg@hp9000a1.uam.mx

    2000-04-28

    We establish a priori conditions for a Gel'fand-Levitan (GL) integral using some results of the Fredholm theory. As consequence, we obtain a recovering formula for the potential of the coupled nonlinear Schroedinger equations. The remarkable fact is that the recovering formula is given in terms of the solutions of a classical GL-integral equation. (author)

  1. Evaluation of an automated struvite reactor to recover phosphorus ...

    In the present study we attempted to develop a reactor system to recover phosphorus by struvite precipitation, and which can be installed anywhere in the field without access to a laboratory. A reactor was developed that can run fully automated and recover up to 93% of total phosphorus (total P). Turbidity and conductivity ...

  2. Research on a Household Dual Heat Source Heat Pump Water Heater with Preheater Based on ASPEN PLUS

    Xiang Gou

    2016-12-01

    Full Text Available This article proposes a dual heat source heat pump bathroom unit with preheater which is feasible for a single family. The system effectively integrates the air source heat pump (ASHP and wastewater source heat pump (WSHP technologies, and incorporates a preheater to recover shower wastewater heat and thus improve the total coefficient of performance (COP of the system, and it has no electric auxiliary heating device, which is favorable to improve the security of the system operation. The process simulation software ASPEN PLUS, widely used in the design and optimization of thermodynamic systems, was used to simulate various cases of system use and to analyze the impact of the preheater on the system. The average COP value of a system with preheater is 6.588 and without preheater it is 4.677. Based on the optimization and analysis, under the standard conditions of air at 25 °C, relative humidity of 70%, wastewater at 35 °C, wastewater flow rate of 0.07 kg/s, tap water at 15 °C, and condenser outlet water temperature at 50 °C, the theoretical COP of the system can reach 9.784 at an evaporating temperature of 14.96 °C, condensing temperature of 48.74 °C, and preheated water temperature of 27.19 °C.

  3. Evaluating the potential of process sites for waste heat recovery

    Oluleye, Gbemi; Jobson, Megan; Smith, Robin; Perry, Simon J.

    2016-01-01

    Highlights: • Analysis considers the temperature and duties of the available waste heat. • Models for organic Rankine cycles, absorption heat pumps and chillers proposed. • Exploitation of waste heat from site processes and utility systems. • Concept of a site energy efficiency introduced. • Case study presented to illustrate application of the proposed methodology. - Abstract: As a result of depleting reserves of fossil fuels, conventional energy sources are becoming less available. In spite of this, energy is still being wasted, especially in the form of heat. The energy efficiency of process sites (defined as useful energy output per unit of energy input) may be increased through waste heat utilisation, thereby resulting in primary energy savings. In this work, waste heat is defined and a methodology developed to identify the potential for waste heat recovery in process sites; considering the temperature and quantity of waste heat sources from the site processes and the site utility system (including fired heaters and, the cogeneration, cooling and refrigeration systems). The concept of the energy efficiency of a site is introduced – the fraction of the energy inputs that is converted into useful energy (heat or power or cooling) to support the methodology. Furthermore, simplified mathematical models of waste heat recovery technologies using heat as primary energy source, including organic Rankine cycles (using both pure and mixed organics as working fluids), absorption chillers and absorption heat pumps are developed to support the methodology. These models are applied to assess the potential for recovery of useful energy from waste heat. The methodology is illustrated for an existing process site using a case study of a petroleum refinery. The energy efficiency of the site increases by 10% as a result of waste heat recovery. If there is an infinite demand for recovered energy (i.e. all the recoverable waste heat sources are exploited), the site

  4. Solid recovered fuel production through the mechanical-biological treatment of wastes

    Velis, C. A.

    2010-01-01

    This thesis is concerned with the production of solid recovered fuel (SRF) from municipal solid waste using mechanical biological treatment (MBT) plants. It describes the first in-depth analysis of a UK MBT plant and addresses the fundamental research question: are MBT plants and their unit operations optimised to produce high quality SRF in the UK? A critical review of the process science and engineering of MBT provides timely insights into the quality management and standa...

  5. Recovering method for solid waste and facility therefor

    Omura, Yutaka

    1998-01-01

    When recovering solid wastes in a dry-type storage vessel, a crusher is hoisted down from a cask, and the crusher is operated to crush the solid wastes while holding them. The crushed wastes are temporarily stored at the upper portion of the crusher, and recovered as crushed wastes. In this case, the crusher is turned down, and a shielding vessel is laid the recover downwardly to temporary store the crushed wastes in the shielding vessel. Then, the crusher and the shielding vessel are turned 180deg to contain the crushed wastes into the shielding vessel. With such procedures, the stored solid wastes can be recovered reliably, the stored solid wastes can be reduced in the size, and efficiency of recovering operation can be improved. (T.M.)

  6. Industrial excess heat for district heating in Denmark

    Bühler, Fabian; Petrovic, Stefan; Karlsson, Kenneth Bernard

    2017-01-01

    analyses excess heat sources from the industrial sector and how they could be used for district heating. This method first allocates excess heat to single production units by introducing and validating a new approach. Spatial analysis of the heat sources and consumers are then performed to evaluate...... the potential for using them for district heating. In this way the theoretical potential of using the excess heat for covering the heating demand of buildings is determined. Through the use of industry specific temperature profiles the heat usable directly or via heat pumps is further found. A sensitivity...... analysis investigates the impact of future energy efficiency measures in the industry, buildings and the district heating grid on the national potential. The results show that for the case study of Denmark, 1.36 TWh of district heat could be provided annually with industrial excess heat from thermal...

  7. Environmental and energy efficiency evaluation of residential gas and heat pump heating

    Ganji, A.R.

    1993-01-01

    Energy efficiency and source air pollutant emission factors of gas heaters, gas engine heat pumps, and electric heat pumps for domestic heating have been evaluated and compared. The analysis shows that with the present state of technology, gas engine heat pumps have the highest energy efficiency followed by electric heat pumps and then gas heaters. Electric heat pumps produce more than twice as much NO x , and comparable CO 2 and CO per unit of useful heating energy compared to natural gas heaters. CO production per unit of useful heating energy from gas engine heat pumps without any emission control is substantially higher than electric heat pumps and natural gas heaters. NO x production per unit of useful heating energy from natural gas engine heat pumps (using lean burn technology) without any emission control is about the same as effective NO x production from electric heat pumps. Gas engine heat pumps produce about one-half CO 2 compared to electric heat pumps

  8. Performance investigation of advanced adsorption desalination cycle with condenser-evaporator heat recovery scheme

    Thu, Kyaw

    2013-01-01

    Energy or heat recovery schemes are keys for the performance improvement of any heat-activated cycles such as the absorption and adsorption cycles. We present two innovative heat recovery schemes between the condensing and evaporating units of an adsorption desalination (AD) cycle. By recovering the latent heat of condenser and dumping it into the evaporative process of the evaporator, it elevates the evaporating temperature and hence the adsorption pressure seen by the adsorbent. From isotherms, this has an effect of increasing the vapour uptake. In the proposed configurations, one approach is simply to have a run-about water circuit between the condenser and the evaporator and a pump is used to achieve the water circulation. This run-around circuit is a practical method for retrofitting purposes. The second method is targeted towards a new AD cycle where an encapsulated condenser-evaporator unit is employed. The heat transfer between the condensing and evaporative vapour is almost immediate and the processes occur in a fully integrated vessel, thereby minimizing the heat transfer resistances of heat exchangers. © 2013 Desalination Publications.

  9. Heat pipe heat storage performance

    Caruso, A; Pasquetti, R [Univ. de Provence, Marseille (FR). Inst. Universitaire des Systemes; Grakovich, L P; Vasiliev, L L [A.V. Luikov Heat and Mass Transfer Inst. of the BSSR, Academy of Sciences, Minsk (BY)

    1989-01-01

    Heat storage offers essential thermal energy saving for heating. A ground heat store equipped with heat pipes connecting it with a heat source and to the user is considered in this paper. It has been shown that such a heat exchanging system along with a batch energy source meets, to a considerable extent, house heating requirements. (author).

  10. Simulation and experimental study of solar-absorption heat transformer integrating with two-stage high temperature vapor compression heat pump

    Nattaporn Chaiyat

    2014-11-01

    Full Text Available In this study, simulation and experiment studies of a 10 kW solar H2O–LiBr absorption heat transformer (AHT integrating with a two-stage vapor compression heat pump (VCHP were carried out. The whole system was named as compression/absorption heat transformer (CAHT. The VCHP was used to recover rejected heat at the AHT condenser which was transferred back to the AHT evaporator at a higher temperature. The AHT unit took solar heat from a set of flat-plate solar collectors in parallel connection. R-134a and R-123 were refrigerants in the VCHP cycle. From the simulation, the total cycle coefficient (COP of the solar-CAHT was 0.71 compared with 0.49 of the normal solar-AHT. From the experiment, the total cycle COPs of the solar-CAHT and the solar-AHT were 0.62 and 0.39, respectively. The experimental results were lower than those of the simulated models due to the oversize of the experimental compressor. The annual expense of the solar-CAHT was found to be 5113 USD which was lower than 5418 USD of the solar-AHT. So it could be concluded that the modified unit was beneficial than the normal unit in terms of energy efficiency and economic expense.

  11. IEA Annex 26: Advanced Supermarket Refrigeration/Heat Recovery Systems

    Baxter, VAN

    2003-05-19

    has its own refrigeration unit; low-charge direct expansion--similar to conventional multiplex refrigeration systems but with improved controls to limit charge. Means to integrate store HVAC systems for space heating/cooling with the refrigeration system have been investigated as well. One approach is to use heat pumps to recover refrigeration waste heat and raise it to a sufficient level to provide for store heating needs. Another involves use of combined heating and power (CHP) or combined cooling, heating, and power (CCHP) systems to integrate the refrigeration, HVAC, and power services in stores. Other methods including direct recovery of refrigeration reject heat for space and water heating have also been examined.

  12. Result of comparative experiment on environmental comfort in room using hot heat environment testing unit. Onnetsu kankyo shiken unit ni yoru shitsunai kankyo no kaitekisa no hikaku jikken kekka ni tsuite

    Fujiwara, T; Kawashima, K [The Hokkaido Electric Power Co. Inc., Sapporo (Japan)

    1991-11-20

    Measurements were carried out on three buildings having different heat insulation, airtightness and heat capacity for testing the hot heast enviroments (having a room size of about 4.6 m{times}3.7m{times}2.3 m) as to the temperature differences between the upper and lower parts of the room and the MRT (mean radiation temperature, representing the temperature of radiation from the wall face). These are compared according to types of heating appliance. The result is summarize as follows: The temperature difference in the upper and lower parts is affected largely by the airtightness of the building, the difference being capable of getting reduced by rasing the airtightness even in a buildings low in heat insulation. In a building with low airtightness, type of heating appliance and its installation location affect the temperature difference. The MRT is determined determined nearly completely by the heat insulation of the wall face in a room, but it tends to be affected easily by the specification and area of windows. A floor heating system increases the MRT and generates very little difference in temperatures in the upper and lower parts of the room. A comparison using a PMV (one of the indexes for enviromental comfort in a room) was also conducted. 12 figs., 7tabs.

  13. Heat transfer

    First page Back Continue Last page Overview Graphics. Heat transfer. Heat conduction in solid slab. Convective heat transfer. Non-linear temperature. variation due to flow. HEAT FLUX AT SURFACE. conduction/diffusion.

  14. Heat Waves

    Heat Waves Dangers we face during periods of very high temperatures include: Heat cramps: These are muscular pains and spasms due ... that the body is having trouble with the heat. If a heat wave is predicted or happening… - ...

  15. Heat Islands

    EPA's Heat Island Effect Site provides information on heat islands, their impacts, mitigation strategies, related research, a directory of heat island reduction initiatives in U.S. communities, and EPA's Heat Island Reduction Program.

  16. Thermodynamic analysis and performance optimization of an ORC (Organic Rankine Cycle) system for multi-strand waste heat sources in petroleum refining industry

    Song, Jian; Li, Yan; Gu, Chun-wei; Zhang, Li

    2014-01-01

    Low-grade waste heat source accounts for a large part of the total industrial waste heat, which cannot be efficiently recovered. The ORC (Organic Rankine Cycle) system has been proved to be a promising solution for the utilization of low-grade heat sources. It is evident that there might be several waste heat sources distributing in different temperature levels in one industry unit, and the entire recovery system will be extremely large and complex if the different heat sources are utilized one by one through several independent ORC subsystems. This paper aims to design and optimize a comprehensive ORC system to recover multi-strand waste heat sources in Shijiazhuang Refining and Chemical Company in China, involving defining suitable working fluids and operating parameters. Thermal performance is a first priority criterion for the system, and system simplicity, technological feasibility and economic factors are considered during optimization. Four schemes of the recovery system are presented in continuous optimization progress. By comparison, the scheme of dual integrated subsystems with R141B as a working fluid is optimal. Further analysis is implemented from the view of economic factors and off-design conditions. The analytical method and optimization progress presented can be widely applied in similar multi-strand waste heat sources recovery. - Highlights: • This paper focuses on the recovery of multi-strand waste heat sources. • ORC technology is used as a promising solution for the recovery. • Thermal performance, system simplicity and economic factors are considered

  17. Miniature Heat Pipes

    1997-01-01

    Small Business Innovation Research contracts from Goddard Space Flight Center to Thermacore Inc. have fostered the company work on devices tagged "heat pipes" for space application. To control the extreme temperature ranges in space, heat pipes are important to spacecraft. The problem was to maintain an 8-watt central processing unit (CPU) at less than 90 C in a notebook computer using no power, with very little space available and without using forced convection. Thermacore's answer was in the design of a powder metal wick that transfers CPU heat from a tightly confined spot to an area near available air flow. The heat pipe technology permits a notebook computer to be operated in any position without loss of performance. Miniature heat pipe technology has successfully been applied, such as in Pentium Processor notebook computers. The company expects its heat pipes to accommodate desktop computers as well. Cellular phones, camcorders, and other hand-held electronics are forsible applications for heat pipes.

  18. Champagne Heat Pump

    Jones, Jack A.

    2004-01-01

    The term champagne heat pump denotes a developmental heat pump that exploits a cycle of absorption and desorption of carbon dioxide in an alcohol or other organic liquid. Whereas most heat pumps in common use in the United States are energized by mechanical compression, the champagne heat pump is energized by heating. The concept of heat pumps based on other absorption cycles energized by heat has been understood for years, but some of these heat pumps are outlawed in many areas because of the potential hazards posed by leakage of working fluids. For example, in the case of the water/ammonia cycle, there are potential hazards of toxicity and flammability. The organic-liquid/carbon dioxide absorption/desorption cycle of the champagne heat pump is similar to the water/ammonia cycle, but carbon dioxide is nontoxic and environmentally benign, and one can choose an alcohol or other organic liquid that is also relatively nontoxic and environmentally benign. Two candidate nonalcohol organic liquids are isobutyl acetate and amyl acetate. Although alcohols and many other organic liquids are flammable, they present little or no flammability hazard in the champagne heat pump because only the nonflammable carbon dioxide component of the refrigerant mixture is circulated to the evaporator and condenser heat exchangers, which are the only components of the heat pump in direct contact with air in habitable spaces.

  19. Mechanical lifter for recovering highly viscous oil and bitumens

    Rakhmanov, R N; Akhunov, A M; Asfandiyarov, Kh A; Maksutov, R A

    1982-01-01

    A mechanical lifter is described for recovering highly viscous oil and bitumens. The lifter differs from the known and has significant advantages over them. The lifter was made and tested on a stand well.

  20. Transuranium element recovering method for spent nuclear fuel

    Todokoro, Akio; Kihara, Yoshiyuki; Okada, Hisashi

    1998-01-01

    Spent fuels are dissolved in nitric acid, the obtained dissolution liquid is oxidized by electrolysis, and nitric acid of transuranium elements are precipitated together with nitric acid of uranium elements from the dissolution solution and recovered. Namely, the transuranium elements are oxidized to an atomic value level at which nitric acid can be precipitated by an oxidizing catalyst, and cooled to precipitate nitric acid of transuranium elements together with nitric acid of transuranium elements, accordingly, it is not necessary to use a solvent which has been used so far upon recovering transuranium elements. Since no solvent waste is generated, a recovery method taking the circumstance into consideration can be provided. Further, nitric acid of uranium elements and nitric acid of transuranium elements precipitated and recovered together are dissolved in nitric acid again, cooled and only uranium elements are precipitated selectively, and recovered by filtration. The amount of wastes can be reduced to thereby enabling to mitigate control for processing. (N.H.)

  1. Pyrochemical investigations into recovering plutonium from americium extraction salt residues

    Fife, K.W.; West, M.H.

    1987-05-01

    Progress into developing a pyrochemical technique for separating and recovering plutonium from spent americium extraction waste salts has concentrated on selective chemical reduction with lanthanum metal and calcium metal and on the solvent extraction of americium with calcium metal. Both techniques are effective for recovering plutonium from the waste salt, although neither appears suitable as a separation technique for recycling a plutonium stream back to mainline purification processes. 17 refs., 13 figs., 2 tabs

  2. Recovering heavy rare earth metals from magnet scrap

    Ott, Ryan T.; McCallum, Ralph W.; Jones, Lawrence L.

    2017-08-08

    A method of treating rare earth metal-bearing permanent magnet scrap, waste or other material in a manner to recover the heavy rare earth metal content separately from the light rare earth metal content. The heavy rare earth metal content can be recovered either as a heavy rare earth metal-enriched iron based alloy or as a heavy rare earth metal based alloy.

  3. Decentralized central heating

    Savic, S.; Hudjera, A.

    1994-08-04

    The decentralized central heating is essentially based on new technical solutions for an independent heating unit, which allows up to 20% collectible energy savings and up to 15% savings in built-in-material. These savings are already made possible by the fact that the elements described under point A are thus eliminated from the classical heating. The thus superfluous made elements are replaced by new technical solutions described under point B - technical problem - and point E - patent claim. The technical solutions described in detail under point B and point E form together a technical unit and are essential parts of the invention protected by the patent. (author)

  4. Solar heating system

    Schreyer, James M.; Dorsey, George F.

    1982-01-01

    An improved solar heating system in which the incident radiation of the sun is absorbed on collector panels, transferred to a storage unit and then distributed as heat for a building and the like. The improvement is obtained by utilizing a storage unit comprising separate compartments containing an array of materials having different melting points ranging from 75.degree. to 180.degree. F. The materials in the storage system are melted in accordance with the amount of heat absorbed from the sun and then transferred to the storage system. An efficient low volume storage system is provided by utilizing the latent heat of fusion of the materials as they change states in storing and releasing heat for distribution.

  5. Improved solar heating systems

    Schreyer, J.M.; Dorsey, G.F.

    1980-05-16

    An improved solar heating system is described in which the incident radiation of the sun is absorbed on collector panels, transferred to a storage unit and then distributed as heat for a building and the like. The improvement is obtained by utilizing a storage unit comprising separate compartments containing an array of materials having different melting points ranging from 75 to 180/sup 0/F. The materials in the storage system are melted in accordance with the amount of heat absorbed from the sun and then transferred to the storage system. An efficient low volume storage system is provided by utilizing the latent heat of fusion of the materials as they change states in storing ad releasing heat for distribution.

  6. Heat jettisoning from solar-thermal driven LiBr-H{sub 2}O absorber cooling units by pulsed spraying a dry cooler with water; Waermeabwurf aus einer solarthermisch getriebenen LiBr- H{sub 2}O Absorptionskaeltemaschine durch gepulstes Bespruehen eines Trockenkuehlers mit Wasser

    Gantenbein, P.; Helfenberger, R.; Frank, E.

    2010-07-01

    This short, illustrated final report discusses the removal of heat from solar-thermal driven LiBr-H{sub 2}O absorber cooling units by pulsed spraying a dry cooler with water. The reduction of electricity consumption for room cooling using conventional chillers is examined. Heat dissipation using open cooling towers and the disadvantages encountered are compared with heat dissipation using a dry cooler with heat-exchanger and fans. Additional evaporation cooling achieved by spraying the heat exchanger with water is described and discussed. The results of measurements made at the Institute for Solar Technology in Rapperswil, Switzerland, are presented and discussed.

  7. Bulk and mechanical properties of the Paintbrush tuff recovered from borehole USW NRG-6: Data report

    Martin, R.J.; Boyd, P.J.; Noel, J.S.; Price, R.H.

    1994-11-01

    Experimental results are presented for bulk and mechanical properties measurements on specimens of the Paintbrush tuff recovered from borehole USW NRG-6 at Yucca Mountain, Nevada. Measurements have been performed on four thermal/mechanical units, TCw, PTn, TSw1 and TSw2. On each specimen the following bulk properties have been reported: dry bulk density, saturated bulk density, average grain density, and porosity. Unconfined compression to failure, confined compression to failure, and indirect tensile strength tests were performed on selected specimens recovered from the borehole. In addition, compressional and shear wave velocities were measured on specimens designated for unconfined compression and confined compression experiments. Measurements were conducted at room temperature on nominally water saturated specimens; however, some specimens of PTn were tested in a room dry condition. The nominal strain rate for the fracture experiments was 10 -5 s -1

  8. Heat exchangers

    Schmidt, E L; Eisenmann, G; Hahne, E [Stuttgart Univ. (TH) (F.R. Germany). Inst. fuer Thermodynamik und Waermetechnik

    1976-04-01

    A survey is presented on publications on design, heat transfer, form factors, free convection, evaporation processes, cooling towers, condensation, annular gap, cross-flowed cylinders, axial flow through a bundle of tubes, roughnesses, convective heat transfer, loss of pressure, radiative heat transfer, finned surfaces, spiral heat exchangers, curved pipes, regeneraters, heat pipes, heat carriers, scaling, heat recovery systems, materials selection, strength calculation, control, instabilities, automation of circuits, operational problems and optimization.

  9. Analysis of the heat transfer mechanisms during energy storage in a Phase Change Material filled vertical finned cylindrical unit for free cooling application

    Solomon, Gnanadurai Ravikumar; Velraj, Ramalingam

    2013-01-01

    Highlights: • Freezing behavior of a PCM, in a cylinder with annular longitudinal fins is presented. • Among various fin heights, 20 mm fin contribute maximum heat transfer enhancement. • Addition of fins plays a contradictory role during the sensible cooling of liquid PCM. • The fin effect along with external cooling, vary the sensible cooling rate of liquid PCM. • The surface convective resistance dominated over the conductive resistance of PCM. - Abstract: The heat transfer performance of the Phase Change Material (PCM) used in free cooling application is low due to poor thermal conductivity. The addition of fins to enhance the heat transfer during solidification process is commonly employed, to address this. However for application such as free cooling, where the driving temperature potential is very less, the present experimental study is intended to investigate the sensible and subcooling phenomena during the outward cylindrical solidification of the PCM stored on the annulus side, along with 8 longitudinal uniformly spaced copper fins of different heights. The performance of the fins during solidification is analyzed, and the best suitable height is arrived at. The addition of fins plays a contradicting role during the sensible cooling of the liquid PCM, due to the suppression of free convection. The external cooling conditions along with the effect of the fin, vary the sensible cooling rate of the liquid PCM, that influences the subcooling effect, and also drifts the temperature at which major phase change occurs. In addition, the effects due to the inlet velocity of the heat transfer fluid, and its temperature on heat transfer are investigated and reported. The increase in velocity decreases the duration of solidification, and this effect is more pronounced towards the entry region, due to the higher local convective heat transfer co-efficient and a comparatively higher driving temperature potential

  10. Modeling of Heat and Mass Transfer in a TEC-Driven Lyophilizer

    Yuan, Zeng-Guang; Hegde, Uday; Litwiller, Eric; Flynn, Michael; Fisher, John

    2006-01-01

    Dewatering of wet waste during space exploration missions is important for crew safety as it stabilizes the waste. It may also be used to recover water and serve as a preconditioning step for waste compaction. A thermoelectric cooler (TEC)-driven lyophilizer is under development at NASA Ames Research Center for this purpose. It has three major components: (i) an evaporator section where water vapor sublimes from the frozen waste, (ii) a condenser section where this water vapor deposits as ice, and (iii) a TEC section which serves as a heat pump to transfer heat from the condenser to the evaporator. This paper analyses the heat and mass transfer processes in the lyophilizer in an effort to understand the ice formation behavior in the condenser. The analysis is supported by experimental observations of ice formation patterns in two different condenser units.

  11. Method of recovering phosphoric acid type decontaminating electrolytes by electrodeposition

    Sasaki, Takashi; Wada, Koichi; Kobayashi, Toshio.

    1985-01-01

    Purpose: To recoving phosphoric acid type highly concentrated decontaminating liquid used for the electrolytic decontamination of contaminated equipments, components, etc in nuclear power plants or the like through electrodeposition by diaphragm electrolysis. Method: Before supplying phosphoric acid decontaminating liquid at high concentration used in the electrolytic decontaminating step to an electrodeposition recovering tank, phosphoric acid in the decontaminating electrolyte is extracted with solvents and decomposed liquid extracts (electrolyte reduced with the phosphoric acid component) are supplied to the cathode chamber of the electrodeposition recovering tank, where phosphoric acid is back-extracted with water from the solvents after extraction of phosphoric acid. Then, the back-extracted liquids (aqueous phosphoric acid solution scarcely containing metal ions) are sent to the anode chamber of the electrodeposition recovering tank. Metal ions in the liquid are captured by electrodeposition in the cathode chamber, as well as phosphoric acid in the liquids is concentrated to the initial concentration of the electrolyte in the anode chamber for reuse as the decontaminating electrolyte. As the phosphoric acid extracting agent used in the electrodeposition recovering step for the decontaminating electrolyte, water-insoluble and non-combustible tributyl phosphate (TBP) is most effective. (Horiuchi, T.)

  12. Heat recovery system series arrangements

    Kauffman, Justin P.; Welch, Andrew M.; Dawson, Gregory R.; Minor, Eric N.

    2017-11-14

    The present disclosure is directed to heat recovery systems that employ two or more organic Rankine cycle (ORC) units disposed in series. According to certain embodiments, each ORC unit includes an evaporator that heats an organic working fluid, a turbine generator set that expands the working fluid to generate electricity, a condenser that cools the working fluid, and a pump that returns the working fluid to the evaporator. The heating fluid is directed through each evaporator to heat the working fluid circulating within each ORC unit, and the cooling fluid is directed through each condenser to cool the working fluid circulating within each ORC unit. The heating fluid and the cooling fluid flow through the ORC units in series in the same or opposite directions.

  13. Primary energy savings using heat storage for biomass heating systems

    Mitrović Dejan M.

    2012-01-01

    Full Text Available District heating is an efficient way to provide heat to residential, tertiary and industrial users. The heat storage unit is an insulated water tank that absorbs surplus heat from the boiler. The stored heat in the heat storage unit makes it possible to heat even when the boiler is not working, thus increasing the heating efficiency. In order to save primary energy (fuel, the boiler operates on nominal load every time it is in operation (for the purpose of this research. The aim of this paper is to analyze the water temperature variation in the heat storage, depending on the heat load and the heat storage volume. Heat load is calculated for three reference days, with average daily temperatures from -5 to 5°C. The primary energy savings are also calculated for those days in the case of using heat storage in district heating.[Projekat Ministarstva nauke Republike Srbije, br. TR 33051: The concept of sustainable energy supply of settlements with energy efficient buildings

  14. Energy-Storage Modules for Active Solar Heating and Cooling

    Parker, J. C.

    1982-01-01

    34 page report describes a melting salt hydrate that stores 12 times as much heat as rocks and other heavy materials. Energy is stored mostly as latent heat; that is, heat that can be stored and recovered without any significant change in temperature. Report also describes development, evaluation and testing of permanently sealed modules containing salt hydrate mixture.

  15. Heat Stress

    ... Publications and Products Programs Contact NIOSH NIOSH HEAT STRESS Recommend on Facebook Tweet Share Compartir OSHA-NIOSH ... hot environments may be at risk of heat stress. Exposure to extreme heat can result in occupational ...

  16. Mothers recovering from cocaine addiction: factors affecting parenting skills.

    Coyer, S M

    2001-01-01

    To identify factors that may influence parenting by mothers who are recovering from cocaine addiction. Exploratory descriptive, with in-depth unstructured interviews. Interviews were conducted in the woman's home or in a treatment center. A convenience sample of 11 women recovering from cocaine addiction who were mothers of children 3 years of age and younger. A content analysis was used to analyze the interview data. Two themes, personal/psychologic factors and environmental/contextual factors, and four subthemes emerged. They identify issues that may affect parenting by mothers being treated for cocaine addiction. Subthemes included low self-esteem, difficulty developing a maternal identity, isolation from friends and family, and chronic life stress. This study provides a better understanding of the sources contributing to vulnerability in the parenting role for mothers recovering from cocaine addiction and will assist nurses in providing care for these mothers and their children.

  17. Methods for recovering metals from electronic waste, and related systems

    Lister, Tedd E; Parkman, Jacob A; Diaz Aldana, Luis A; Clark, Gemma; Dufek, Eric J; Keller, Philip

    2017-10-03

    A method of recovering metals from electronic waste comprises providing a powder comprising electronic waste in at least a first reactor and a second reactor and providing an electrolyte comprising at least ferric ions in an electrochemical cell in fluid communication with the first reactor and the second reactor. The method further includes contacting the powders within the first reactor and the second reactor with the electrolyte to dissolve at least one base metal from each reactor into the electrolyte and reduce at least some of the ferric ions to ferrous ions. The ferrous ions are oxidized at an anode of the electrochemical cell to regenerate the ferric ions. The powder within the second reactor comprises a higher weight percent of the at least one base metal than the powder in the first reactor. Additional methods of recovering metals from electronic waste are also described, as well as an apparatus of recovering metals from electronic waste.

  18. A theoretical framework for understanding recovered memory experiences.

    Brewin, Chris R

    2012-01-01

    If recovered memory experiences appear counter-intuitive, this is in part due to misconceptions about trauma and memory, and to a failure to adopt a comprehensive model of memory that distinguishes personal semantic memory, autobiographical event memory, and memory appraisal. Memory performance is generally superior when events, including traumas, are central to identity. Prolonged trauma in childhood, however, can produce severe identity disturbances that may interfere with the encoding and later retrieval of personal semantic and autobiographical event information. High levels of emotion either at encoding or recall can also interfere with the creation of coherent narrative memories. For example, high levels of shock and fear when memories are recovered unexpectedly may lead to the experience of vivid flashbacks. Memory appraisals may also influence the sense that an event has been forgotten for a long time. Recovered memories, although unusual, do not contradict what we know about how memory works.

  19. Solid-Solid Vacuum Regolith Heat-Exchanger for Oxygen Production, Phase I

    National Aeronautics and Space Administration — This SBIR Phase-1 project will demonstrate the feasibility of using a novel coaxial counterflow solid-solid heat exchanger to recover heat energy from spent regolith...

  20. Two-phase plate-fin heat exchanger modeling for waste heat recovery systems in diesel engines

    Feru, E.; Jager, de A.G.; Willems, F.P.T.; Steinbuch, M.

    2014-01-01

    This paper presents the modeling and model validation for a modular two-phase heat exchanger that recovers energy in heavy-duty diesel engines. The model is developed for temperature and vapor quality prediction and for control design of the waste heat recovery system. In the studied waste heat

  1. Simultaneous power generation and heat recovery using a heat pipe assisted thermoelectric generator system

    Remeli, Muhammad Fairuz; Tan, Lippong; Date, Abhijit; Singh, Baljit; Akbarzadeh, Aliakbar

    2015-01-01

    Highlights: • A new passive power cogeneration system using industrial waste heat was introduced. • Heat pipes and thermoelectrics were used for recovering waste heat and electricity. • Theoretical model predicted the 2 kW test rig could recover 1.345 kW thermal power. • 10.39 W electrical power was produced equivalent to 0.77% conversion efficiency. - Abstract: This research explores a new method of recovering waste heat and electricity using a combination of heat pipes and thermoelectric generators (HP-TEG). The HP-TEG system consists of Bismuth Telluride (Bi 2 Te 3 ) based thermoelectric generators (TEGs), which are sandwiched between two finned heat pipes to achieve a temperature gradient across the TEG for thermoelectricity generation. A theoretical model was developed to predict the waste heat recovery and electricity conversion performances of the HP-TEG system under different parametric conditions. The modelling results show that the HP-TEG system has the capability of recovering 1.345 kW of waste heat and generating 10.39 W of electrical power using 8 installed TEGs. An experimental test bench for the HP-TEG system is under development and will be discussed in this paper

  2. Air source integrated heat pump simulation model for EnergyPlus

    Shen, Bo; New, Joshua; Baxter, Van

    2017-12-01

    An Air Source Integrated Heat Pump (AS-IHP) is an air source, multi-functional spacing conditioning unit with water heating function (WH), which can lead to great energy savings by recovering the condensing waste heat for domestic water heating. This paper summarizes development of the EnergyPlus AS-IHP model, introducing the physics, sub-models, working modes, and control logic. Based on the model, building energy simulations were conducted to demonstrate greater than 50% annual energy savings, in comparison to a baseline heat pump with electric water heater, over 10 US cities, using the EnergyPlus quick-service restaurant template building. We assessed water heating energy saving potentials using AS-IHP versus both gas and electric baseline systems, and pointed out climate zones where AS-IHPs are promising. In addition, a grid integration strategy was investigated to reveal further energy saving and electricity cost reduction potentials, via increasing the water heating set point temperature during off-peak hours and using larger water tanks.

  3. Process for recovering uranium from wet process phosphoric acid

    Pyrih, R.Z.; Rickard, S.; Carrington, F.

    1982-01-01

    A process for recovering uranium from phosphoric acid solutions uses an acidified alkali metal carbonate solution for the second-stage strip of uranyl uranium from the ion-exchange solution. The stripped solution is then recycled to the ion-exchange circuit. In the first stripping stage the ion-exchange solution containing the recovered uranyl uranium and an inert organic diluent is stripped with ammonium carbonate, producing a slurry of ammonium uranyl tricarbonate. The second strip, with a solution of 50-200 grams per litre of sodium carbonate eliminates the problems of inadequate removal of phosphorus, iron and vanadium impurities, solids accumulation, and phase separation in the strip circuit

  4. Recovering metal values hydrometallurgically from spent dry battery cells

    Rabah, M. A.; Barakat, M. A.; Mahrous, Y. Sh.

    1999-12-01

    A hydro-pyrometallurgical method was used to recover metal values from spent dry battery cells. Water-soluble ingredients were filtered, and solid residue was sorted by magnetic separation and water flotation. Parameters affecting the recovery efficiency were also studied. Results revealed that metallic parts, carbon rods, and paper were safely recovered; pure NH4Cl, MnO2, and ZnCl2 salts were obtained. Maximum recovery efficiencies reached 93 percent for manganese and 99.5 percent for zinc and NH4.

  5. Beam position monitor for energy recovered linac beams

    Powers, Thomas; Evtushenko, Pavel

    2017-06-06

    A method of determining the beam position in an energy recovered linac (ERL). The method makes use of in phase and quadrature (I/Q) demodulation techniques to separate the pickup signal generated by the electromagnetic fields generated by the first and second pass beam in the energy recovered linac. The method includes using analog or digital based I/Q demodulation techniques in order to measure the relative amplitude of the signals from a position sensitive beam pickup such as a button, strip line or microstripline beam position monitor.

  6. Research of the heat exchanging processes running in the heating and hot water supply loops of the coil heat exchangers

    Ірина Геннадіївна Шитікова

    2016-11-01

    Full Text Available The fuel-energy complex research has made it possible to disclose a huge power-saving potential in the municipal heat-and-power engineering. Power-and-resource-saving units and systems are becoming extremely urgent because of the power engineering crisis expansion. The self-adjusting heat supply system from the individual heating points with the heat-accumulating units and coil heat exchangers for independent heating and water supply systems has been examined. Coil heat exchangers are used in municipal heating for heat transfer (e.g. geothermal waters for the independent mains of the heating and hot water supply systems. The heat engineering calculation of the heating and accumulating unit with the coil heat exchanger for independent heat supply systems from individual heater was performed and experimental data were received at the experimental industrial unit under the laboratory conditions. The peculiarities of the flows in the intertubular space, their influence on the heat exchange and temperatures of the first and intermediate mains have been shown. It is important to know the processes running inside the apparatus to be able to improve the technical characteristics of the three-loop coil heat exchanger. The task solution will make it possible to save the materials consumption for the three-loop coil heat exchangers in the future

  7. Solar/electric heating systems for the future energy system

    Furbo, Simon; Dannemand, Mark; Perers, Bengt

    elements/heat pump, advanced heat storage tanks and advanced control systems. Heat is produced by solar collectors in sunny periods and by electrical heating elements/heat pump. The electrical heating elements/heat pump will be in operation in periods where the heat demand cannot be covered by solar energy....... The aim is to use the auxiliary heating units when the electricity price is low, e.g. due to large electricity production by wind turbines. The unit is equipped with an advanced control system where the control of the auxiliary heating is based on forecasts of the electricity price, the heat demand...

  8. Non-linear model predictive supervisory controller for building, air handling unit with recuperator and refrigeration system with heat waste recovery

    Minko, Tomasz; Wisniewski, Rafal; Bendtsen, Jan Dimon

    2016-01-01

    . The retrieved heat excess can be stored in the water tank. For this purpose the charging and the discharging water loops has been designed. We present the non-linear model of the above described system and a non-linear model predictive supervisory controller that according to the received price signal......, occupancy information and ambient temperature minimizes the operation cost of the whole system and distributes set points to local controllers of supermarkets subsystems. We find that when reliable information about the high price period is available, it is profitable to use the refrigeration system...... to generate heat during the low price period, store it and use it to substitute the conventional heater during the high price period....

  9. A Study on Heat-up Phenomena of the RHR Pump Room in KORI Unit 2 for the Loss of HVAC Accidents

    Yoon, Churl; Park, Jin Hee; Lim, Ho Gon; Han, Sang Hoon

    2009-01-01

    In PSA(Probabilistic Safety Analysis) Models, the HVAC(Heating, Ventilation, and Air Condition) system is essential for the various vital mitigation safety systems operating during a mission time. So far, the unavailability of a safety system when the HVAC system fails has been applied conservatively or optimistically based on operating experience and expert judgment, so the total core damage frequency could be unrealistic. When the HVAC system of a nuclear power plant fails, it is one of the main issues in a PSA FT (Fault Tree) model to estimate the transient temperature variations of some component rooms. The purpose of this study is to establish a heat-up prediction model by using direct measuring and CFD(Computational Fluid Dynamics) analyses

  10. Design of A District Heating System Including The Upgrading of Residual Industrial Waste Heat

    Falcao, P.W.; Mesbah, A.; Suherman, M.V.; Wennekes, S.

    2005-01-01

    This study was aimed to evaluate the feasibility of using a waste heat stream from DSM for a District Heating System. A conceptual design was carried out with emphasis on the unit for upgrading the residual waste heat. Having reviewed heat pump technology, mechanical heat pump was found to be the

  11. Cooldown to residual heat removal entry conditions using atmospheric dump valves and auxiliary pressurizer spray following a loss-of-offsite power at Calvert Cliffs, Unit 1

    Jenks, R.P.

    1984-01-01

    An investigation of cooldown using atmospheric dump valves (ADVs) and auxiliary pressurizer spray (APS) following loss-of-offsite power at Calvert Cliffs-1 showed residual heat removal entry conditions could not be reached with the plant ADVs alone. Use of APS with the plant ADVs enhanced depressurization, but still provided insufficient cooldown. Effective cooldown and depressurization was shown to occur when rated steady state flow through the ADVs was increased by a factor of four. 6 refs., 30 figs., 2 tabs

  12. Thermodynamic performance analysis of a novel electricity-heating cogeneration system (EHCS) based on absorption heat pump applied in the coal-fired power plant

    Zhang, Hongsheng; Li, Zhenlin; Zhao, Hongbin

    2015-01-01

    Highlights: • Presented a novel waste heat recovery method for Combined Heat and Power system. • Established models of the integrated system based on energy and exergy analysis. • Adopted both design and actual data ensuring the reliability of analysis results. - Abstract: A novel electricity-heating cogeneration system (EHCS) which is equipped with an absorption heat pump (AHP) system to recover waste heat from exhaust steam of the steam turbines in coal-fired thermal power plants is proposed to reduce heating energy consumption and improve the utilization of the fossil fuels in existing CHP (Combined Heat and Power) systems. According to the first and second thermodynamic law, the changes of the performance evaluation indicators are analyzed, and exergy analyses for key components of the system are carried out as well as changes of exergy indexes focusing on 135 MW direct air cooling units before and after modification. Compared with the conventional heating system, the output power increases by about 3.58 MW, gross coal consumption rate and total exergy loss respectively reduces by 11.50 g/kW h and 4.649 MW, while the total thermal and exergy efficiency increases by 1.26% and 1.45% in the EHCS when the heating load is 99,918 kJ at 75% THA condition. Meanwhile, the decrement of total exergy loss and increment of total exergy efficiency increase with the increasing of the heating load. The scheme cannot only bring great economic benefits but also save fossil resources, which has a promising market application potential.

  13. Energetic benefits of enhanced summer roosting habitat for little brown bats (Myotis lucifugus) recovering from white-nose syndrome.

    Wilcox, Alana; Willis, Craig K R

    2016-01-01

    Habitat modification can improve outcomes for imperilled wildlife. Insectivorous bats in North America face a range of conservation threats, including habitat loss and white-nose syndrome (WNS). Even healthy bats face energetic constraints during spring, but enhancement of roosting habitat could reduce energetic costs, increase survival and enhance recovery from WNS. We tested the potential of artificial heating of bat roosts as a management tool for threatened bat populations. We predicted that: (i) after hibernation, captive bats would be more likely to select a roost maintained at a temperature near their thermoneutral zone; (ii) bats recovering from WNS at the end of hibernation would show a stronger preference for heated roosts compared with healthy bats; and (iii) heated roosts would result in biologically significant energy savings. We housed two groups of bats (WNS-positive and control) in separate flight cages following hibernation. Over 7.5 weeks, we quantified the presence of individuals in heated vs. unheated bat houses within each cage. We then used a series of bioenergetic models to quantify thermoregulatory costs in each type of roost under a number of scenarios. Bats preferentially selected heated bat houses, but WNS-affected bats were much more likely to use the heated bat house compared with control animals. Our model predicted energy savings of up to 81.2% for bats in artificially heated roosts if roost temperature was allowed to cool at night to facilitate short bouts of torpor. Our results are consistent with research highlighting the importance of roost microclimate and suggest that protection and enhancement of high-quality, natural roosting environments should be a priority response to a range of threats, including WNS. Our findings also suggest the potential of artificially heated bat houses to help populations recover from WNS, but more work is needed before these might be implemented on a large scale.

  14. Investigation of Counter-Flow in a Heat Pipe-Thermoelectric Generator (HPTEG)

    Remeli, Muhammad Fairuz; Singh, Baljit; Affandi, Nor Dalila Nor; Ding, Lai Chet; Date, Abhijit; Akbarzadeh, Aliakbar

    2017-05-01

    This study explores a method of generating electricity while recovering waste heat through the integration of heat pipes and thermoelectric generators (i.e. HPTEG system). The simultaneous waste heat recovery and power generation processes are achieved without the use of any moving parts. The HPTEG system consists of bismuth telluride thermoelectric generators (TEG), which are sandwiched between two finned pipes to achieve a temperature gradient across the TEG for electricity generation. A counter-flow heat exchanger was built using two separate air ducts. The air ducts were thermally coupled using the HPTEG modules. The evaporator section of the heat pipe absorbed the waste heat in a hot air duct. The heat was then transferred across the TEG surfaces. The condenser section of the HPTEG collected the excess heat from the TEG cold side before releasing it to the cold air duct. A 2-kW electrical heater was installed in the hot air duct to simulate the exhaust gas. An air blower was installed at the inlet of each duct to direct the flow of air into the ducts. A theoretical model was developed for predicting the performance of the HPTEG system using the effectiveness-number of transfer units method. The developed model was able to predict the thermal and electrical output of the HPTEG, along with the rate of heat transfer. The results showed that by increasing the cold air velocity, the effectiveness of the heat exchanger was able to be increased from approximately 52% to 58%. As a consequence of the improved heat transfer, maximum power output of 4.3 W was obtained.

  15. Simulation of heat and mass transfer processes in the experimental section of the air-condensing unit of Scientific Production Company "Turbocon"

    Artemov, V. I.; Minko, K. B.; Yan'kov, G. G.; Kiryukhin, A. V.

    2016-05-01

    A mathematical model was developed to be used for numerical analysis of heat and mass transfer processes in the experimental section of the air condenser (ESAC) created in the Scientific Production Company (SPC) "Turbocon" and mounted on the territory of the All-Russia Thermal Engineering Institute. The simulations were performed using the author's CFD code ANES. The verification of the models was carried out involving the experimental data obtained in the tests of ESAC. The operational capability of the proposed models to calculate the processes in steam-air mixture and cooling air and algorithms to take into account the maldistribution in the various rows of tube bundle was shown. Data on the influence of temperature and flow rate of the cooling air on the pressure in the upper header of ESAC, effective heat transfer coefficient, steam flow distribution by tube rows, and the dimensions of the ineffectively operating zones of tube bundle for two schemes of steam-air mixture flow (one-pass and two-pass ones) were presented. It was shown that the pressure behind the turbine (in the upper header) increases significantly at increase of the steam flow rate and reduction of the flow rate of cooling air and its temperature rise, and the maximum value of heat transfer coefficient is fully determined by the flow rate of cooling air. Furthermore, the steam flow rate corresponding to the maximum value of heat transfer coefficient substantially depends on the ambient temperature. The analysis of the effectiveness of the considered schemes of internal coolant flow was carried out, which showed that the two-pass scheme is more effective because it provides lower pressure in the upper header, despite the fact that its hydraulic resistance at fixed flow rate of steam-air mixture is considerably higher than at using the one-pass schema. This result is a consequence of the fact that, in the two-pass scheme, the condensation process involves the larger internal surface of tubes

  16. Heat recovery from flue gas of coal fired installations with reduced pollutant emission - the Zittau process

    Mueller, H; Strauss, R; Hofmann, K -D; Suder, M; Hultsch, T; Wetzel, W; Gabrysch, H; Jung, J [Technische Hochschule, Zittau (German Democratic Republic)

    1989-01-01

    Explains the Zittau technology of combined flue gas heat recovery and flue gas desulfurization in small brown coal fired power plants. Steam generators to be equipped with this technology have 6.5 or 10 t/h steam capacity and are intended for combustion of low-grade brown coal (8.2 MJ/kg). An industrial 6.5 t/h prototype steam generator is in operation and it achieves 95% SO{sub 2} removal from flue gas with 5600 to 7800 mg SO{sub 2} per m{sup 3} of dry flue gas. The Zittau technology is available in 3 variants: with maximum waste heat recovery, with partial waste heat recovery or without waste heat recovery and only wet flue gas scrubbing. Two flowsheets of flue gas and suspension circulation are provided. The first variant recovers 25.7% of nominal heat capacity (1.1 thermal MW from a 4.2 MW steam generator with 6.5 t/h steam capacity), which amounts to economizing 2,400 t/a brown coal equivalent over 4,000 annual operating hours. The second variant recovers 6.5% of waste heat, requiring less investment by installing smaller heat exchangers than used in the first variant. All three variants have contact spray separators, suction units and suspension preparation equipment. Flue gas suspension scrubbing is carried out with fly ash produced by the steam generator. This ash is capable of absorbing 50 to 70% of flue gas SO{sub 2}. Supply of additional ash from other plants achieve a further 25% SO{sub 2} removal; a higher desulfurization degree is obtained by adding limestone to suspensions. 5 refs.

  17. Phosphorus uptake by potato from fertilizers recovered from anaerobic digestion

    Field experiments were conducted in the Columbia Basin of South Central Washington to assess the yield of potato (Solanum tuberosum) in response to application of phosphorus enriched materials recovered from anaerobic digestion of manure. The treatments were comprised of four rates (0, 56, 112 and ...

  18. A probabilistic model to recover individual genomes from metagenomes

    J. Dröge (Johannes); A. Schönhuth (Alexander); A.C. McHardy (Alice)

    2017-01-01

    textabstractShotgun metagenomics of microbial communities reveal information about strains of relevance for applications in medicine, biotechnology and ecology. Recovering their genomes is a crucial but very challenging step due to the complexity of the underlying biological system and technical

  19. Thermoset composite recycling: Properties of recovered glass fiber

    Beauson, Justine; Fraisse, Anthony; Toncelli, C.

    2015-01-01

    Recycling of glass fiber thermoset polymer composite is a challenging topic and a process able to recover the glass fibers original properties in a limited cost is still under investigation. This paper focuses on the recycling technique separating the glass fiber from the matrix material. Four...

  20. Physical activity level among children recovering from severe acute malnutrition

    Babirekere-Iriso, Esther; Rytter, Maren Johanne Heilskov; Namusoke, Hanifa

    2018-01-01

    OBJECTIVE: To assess the level and predictors of physical activity at discharge among children recovering from severe acute malnutrition (SAM). METHODS: We conducted a prospective study among 69 children 6 - 59 months of age admitted with SAM for nutritional rehabilitation at Mulago National...

  1. Method for recovering or recirculating stable nitroxide radicals

    Heeres, Andre; Van Doren, Hendrik Arend; Bleeker, Ido Pieter; Gotlieb, Kornelis Fester.

    1996-01-01

    The invention relates fo a method for recovering stable nitroxide radicals, wherein at least a part of a reaction mixt. consisting of a soln. or suspension, or a filtrate or supernatant of a suspension, in which stable nitroxide radicals are present in non-solid form, is subjected to an azeotropic

  2. Genomovirus Genomes Recovered from Echinothrips americanus Sampled in Florida, USA

    Kraberger, Simona; Polston, Jane E.; Capobianco, Heather M.; Alcalá-Briseño, Ricardo I.; Fontenele, Rafaela S.

    2017-01-01

    ABSTRACT Four genomovirus genomes were recovered from thrips (Echinothrips americanus) collected in Florida, USA. These represent four new species which are members of the Gemycircularvirus (n = 2), Gemyduguivirus (n = 1), and Gemykibivirus (n = 1) genera. This is the first record, to our knowledge, of genomoviruses associated with a phytophagous insect. PMID:28546499

  3. 26 CFR 1.1336-1 - Basis of recovered property.

    2010-04-01

    ... benefits by reason of the basis determined under subparagraph (1) of this paragraph, that it would be... recovered it has an unadjusted basis of $100. After $70 depreciation has been allowed on A, an allocation is sought which would give A an unadjusted basis of $60. Since this is less than the depreciation which is...

  4. Evaluation of an automated struvite reactor to recover phosphorus ...

    2015-04-03

    Apr 3, 2015 ... A reactor was developed that can run fully automated and recover up to 93% ..... uncertainty. This technique will work best when the concentration of ... Ken Jack at the School of Chemical Engineering to help build the reactor ...

  5. Return to Education for Recovering Drug Addicts: The Soilse Project

    Barter, Eric

    2010-01-01

    This article is an account of a return to education course set up to cater to the needs of recovering heroin addicts in a Dublin rehabilitation project in the summer of 2008. It begins with a brief outline of the HSE Soilse rehabilitation and recovery programme and the rationale for seeking association with the Department of Adult and Community…

  6. Waste heat recovery system

    Phi Wah Tooi

    2010-01-01

    Full text: The Konzen in-house designed anaerobic digester system for the POME (Palm Oil Mill Effluent) treatment process is one of the registered Clean Development Mechanism (CDM) projects in Malaysia. It is an organic wastewater treatment process which achieves excellent co-benefits objectives through the prevention of water pollution and reduction of greenhouse gas emissions, which is estimated to be 40,000 to 50,000 t-CO 2 per year. The anaerobic digester was designed in mesophile mode with temperature ranging from 37 degree Celsius to 45 degree Celsius. A microorganisms growth is optimum under moderately warm temperature conditions. The operating temperature of the anaerobic digester needs to be maintained constantly. There are two waste heat recovery systems designed to make the treatment process self-sustaining. The heat recovered will be utilised as a clean energy source to heat up the anaerobic digester indirectly. The first design for the waste heat recovery system utilises heat generated from the flue gas of the biogas flaring system. A stainless steel water tank with an internal water layer is installed at the top level of the flare stack. The circulating water is heated by the methane enriched biogas combustion process. The second design utilizes heat generated during the compression process for the biogas compressor operation. The compressed biogas needs to be cooled before being recycled back into the digester tank for mixing purposes. Both the waste heat recovery systems use a design which applies a common water circulation loop and hot water tank to effectively become a closed loop. The hot water tank will perform both storage and temperature buffer functions. The hot water is then used to heat up recycled sludge from 30 degree Celsius to 45 degree Celsius with the maximum temperature setting at 50 degree Celsius. The recycled sludge line temperature will be measured and monitored by a temperature sensor and transmitter, which will activate the

  7. Heat pumps

    Macmichael, DBA

    1988-01-01

    A fully revised and extended account of the design, manufacture and use of heat pumps in both industrial and domestic applications. Topics covered include a detailed description of the various heat pump cycles, the components of a heat pump system - drive, compressor, heat exchangers etc., and the more practical considerations to be taken into account in their selection.

  8. Process and installation for heat recovery. Verfahren und Anlage zur Waermerueckgewinnung

    Zeller, M.

    1990-01-10

    The patent describes a method for heat recovery from the warmer of two separately conducted streams of a fluid, whereby heat is recovered through a first heat exchanger in the warmer stream of medium, a heat transfer medium in a transmitting circuit and a second heat exchanger in the cooler stream of fluid, whereby the transmitting circuit includes both heat exchangers, characterized in that the recovered thermic output ({Delta}t.Q) is continuously detected and a regulation of the quantity (Q) of heat transfer medium in this circuit to maximum thermic output is effected. (author) 4 figs., 2 refs.

  9. Exergy efficiency enhancement of MSF desalination by heat recovery from hot distillate water stages

    Al-Weshahi, Mohammed A.; Anderson, Alexander; Tian, Guohong

    2013-01-01

    This detailed exergy analysis of a 3800 m 3 /h Multi-Stage Flash (MSF) desalination plant is based on the latest published thermodynamics properties of water and seawater. The parameters of the study were extracted from a validated model of MSF desalination using IPSEpro software. The results confirmed that the overall exergy efficiency of the unit is lower than would be desirable at only 5.8%. Exergy inputs were destroyed by 55%, 17%, 10%, 4.3%, and 14% respectively, in the heat recovery stages, brine heater, heat rejection stages, pumps and brine streams disposal. Moreover, the detail of the study showed that the lowest exergy destruction occurs in the first stage, increasing gradually in heat recovery stages and sharply in heat rejection stages. The study concludes that recovering the heat from the hot distillate water stages can improve unit exergy efficiency from its low 5.8% to a more economical 14%, with the hot water parameters suitable for powering other thermal systems such as absorption chiller and multi-effect desalination

  10. Fighting fire in the heat of the day: An analysis of operational and environmental conditions of use for large airtankers in United States fire suppression

    Crystal S. Stonesifer; Dave Calkin; Matthew P. Thompson; Keith D. Stockmann

    2016-01-01

    Large airtanker use is widespread in wildfire suppression in the United States. The current approach to nationally dispatching the fleet of federal contract airtankers relies on filling requests for airtankers to achieve suppression objectives identified by fire managers at the incident level. In general, demand is met if resources are available, and the...

  11. A synopsis of the wood-based energy and heating industries in the northeastern United States with consideration of potential impacts on future demand for roundwood

    Jan Wiedenback; Chuck D. Ray; Li. Ma

    2011-01-01

    The project team identified 323 facilities in the northeastern United States that input pulpwood or "energy wood." Of these, 88 are located in Pennsylvania, Ohio, and West Virginia, part of the central hardwood forest region. In the 13-state northeastern region, 81 percent of the facilities that use pulp-type roundwood produce an energy-related product. For...

  12. IEA HPP Annex 42 Heat Pumps in Smart Grids - Task 1 Market Overview United States: ORNL/TM-2014/73

    Baxter, Van D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Sikes, Karen [SRA International, Inc., Fairfax, VA (United States); Domitrovic, Ronald [Electric Power Research Institute (EPRI), Palo Alto, CA (United States); Amrane, Karim [Air-Conditioning, Heating, and Refrigeration Inst., Arlington, VA (United States)

    2014-04-01

    As a result of the American Recovery and Reinvestment Act of 2009 (ARRA), rapid deployment of smart meters occurred between 2009 and 2012 in the United States. Now that this large amount of advanced metering infrastructure is installed, utilities are revisiting how to best incorporate them into operations to enhanced power distribution.

  13. Long-term and clinical profile of heart failure with recovered ejection fraction in a non-tertiary hospital.

    Martínez-Mateo, Virgilio; Fernández-Anguita, Manuel; Cejudo, Laura; Martín-Barrios, Eugenia; Paule, Antonio J

    2018-06-05

    Heart failure (HF) with recovered ejection fraction (EF) is emerging as a different HF subtype. There is little information about his clinical profile in hospitals that are not a reference. We analysed characteristics and prognosis in patients with recovered HF followed prospectively in the HF Unit of a non-tertiary hospital. A total of 431 patients with HF with reduced EF were followed (median 50 months, 79.3% males, mean age 70.3±12.2years). Of the patients, 26.9% (N 116) recovered EF, mainly in the first year of follow-up (76.7%). Compared with patients that did not recovered EF in the follow-up, they were younger, rate of ischemic origin of cardiomyopathy was less frequent and presented less comorbidity. Mortality was lower in patients with recovered HF (survival median of 85.2±2.1 vs. 74.2±1.9 months [log-rank χ 2 11.5, P=0.001], hazard ratio 0.37, 95% confidence interval [CI]: 0.21-0.67, P=0.002). Aetiology of deaths was not mainly secondary to HF. Younger age of 68 years (odds ratio [OR] 0-98, 95% CI: 0.96-0,99; P=0.025), ischemic origin (OR 1.12, 95% CI: 1.01-1.21; P=0.003) and use of aldosterone antagonists (OR 1.89, 95% CI: 1.09-3.26; P=0.023) were the variables independently associated to normalisation of EF. HF with recovered EF is a frequent phenomenon. It has a more favourable clinical course, prognosis and basal characteristics than HF with persistent reduced EF. Further studies are needed to identify natural history and optimal medications for HF-recovered patients. Copyright © 2018 Elsevier España, S.L.U. All rights reserved.

  14. Manufacture of heat exchangers

    Burton, J.E.; Tombs, R.W.T.

    1980-01-01

    A tube bundle for use in a heat exchanger has a series of spaced parallel tubes supported by tube plates and is manufactured by depositing welding material around the end of each tube, machining the deposited material to form an annular flange around the end of the tube and welding the flange into apertures in the tube plate. Preferably the tubes have a length which is slightly less than the distance between the outer surfaces of the tube plates and the deposited material is deposited so that it overlaps and protects the end surfaces of the tubes. A plug may be inserted in the bore of the tubes during the welding material deposition which, as described, is effected by manual metal arc welding. One use of heat exchangers incorporating a tube bundle manufactured as above is in apparatus for reducing the volume of, and recovering nitric acid from, radioactive effluents from a nuclear reprocessing plant. (author)

  15. Ventilation with heat recovery

    Tommerup, Henrik M.; Svendsen, Svend

    2005-01-01

    This paper presents the experiences from the use of ventilation with heat recovery in several experimental single-family houses developed and built within the last four years to meet the new Danish energy requirements of 2005. Included are descriptions of the ventilation system components...... and the main functional demands as well as measurements of the thermal efficiency, electricity consumptions and building air tightness. The paper addresses the aspects of minimizing the heat loss from the duct system and the heat recovery unit (when placed in an unheated attic space) in order to obtain...

  16. Industrial waste heat utilization for low temperature district heating

    Fang, Hao; Xia, Jianjun; Zhu, Kan; Su, Yingbo; Jiang, Yi

    2013-01-01

    Large quantities of low grade waste heat are discharged into the environment, mostly via water evaporation, during industrial processes. Putting this industrial waste heat to productive use can reduce fossil fuel usage as well as CO 2 emissions and water dissipation. The purpose of this paper is to propose a holistic approach to the integrated and efficient utilization of low-grade industrial waste heat. Recovering industrial waste heat for use in district heating (DH) can increase the efficiency of the industrial sector and the DH system, in a cost-efficient way defined by the index of investment vs. carbon reduction (ICR). Furthermore, low temperature DH network greatly benefits the recovery rate of industrial waste heat. Based on data analysis and in-situ investigations, this paper discusses the potential for the implementation of such an approach in northern China, where conventional heat sources for DH are insufficient. The universal design approach to industrial-waste-heat based DH is proposed. Through a demonstration project, this approach is introduced in detail. This study finds three advantages to this approach: (1) improvement of the thermal energy efficiency of industrial factories; (2) more cost-efficient than the traditional heating mode; and (3) CO 2 and pollutant emission reduction as well as water conservation. -- Highlights: •We review situation of industrial waste heat recovery with a global perspective. •We present a way to analyze the potential to utilize industrial waste heat for DH. •Northern China has huge potential for using low-grade industrial waste heat for DH. •A demonstration project is introduced using the universal approach we propose. •It proves huge benefits for factories, heat-supply companies and the society

  17. Fuel fired heat sources

    Ortlinghaus, U

    1977-09-08

    Fuel fired heat sources with a valve-controlled ignition and main burner, whose flame is monitored and whose control valve is closed or opened by a controller according to the control deviation between actual and reference heat source temperature, previously suffered the disadvantage of high consumption of ignition gas. According to the invention this disadvantage is avoided by closing the ignition valve from the controller via a delay unit and having the delay time of the delay unit controlled either by the temperature measured by the sensor or increasing it with increasing deviation of the actual value of pre-temperature from the reference value of the pre-temperature.

  18. Investigation of four problems on the units of material and its properties, energy with heat and temperature in the secondary school physics textbooks

    Kavcar, Nevzat; Özen, Ali Ihsan

    2017-02-01

    In the present study, three units in textbooks in accordance with the 2013 Secondary School Physics Curriculum were analyzed in defined four problems, and some recommendations were made. The study carried out in the Spring semester of education year 2015-2016, within the scope of an undergraduate course. Method of the study is the descriptive model based on qualitative research technics. The data collection instruments were textbook evaluation reports prepared by the participants and pre-service teachers, and presentations reflecting teachers' and pre-service teachers' ideas on the textbooks. A document analysis was conducted by means of these data collection tools. It has been concluded that in the related units a significant shortcoming is not found regarding being student-centered, activity and contex-based approximations. However, some shortcomings were found in activity-gain concordance with measurement and evaluation applications. On the basis of the collected data, some recommendations for improving the textbooks have been presented.

  19. Failure study of helium-cooled tungsten divertor plasma-facing units tested at DEMO relevant steady-state heat loads

    Ritz, G; Pintsuk, G; Linke, J; Hirai, T; Norajitra, P; Reiser, J; Giniyatulin, R; Makhankov, A; Mazul, I

    2009-01-01

    Tungsten was selected as armor material for the helium-cooled divertor in future DEMO-type fusion reactors and fusion power plants. After realizing the design and testing of them under cyclic thermal loads of up to ∼14 MW m -2 , the tungsten divertor plasma-facing units were examined by metallography; they revealed failures such as cracks at the thermal loaded and as-machined surfaces, as well as degradation of the brazing layers. Furthermore, in order to optimize the machining processes, the quality of tungsten surfaces prepared by turning, milling and using a diamond cutting wheel were examined. This paper presents a metallographic examination of the tungsten plasma-facing units as well as technical studies and the characterization on machining of tungsten and alternative brazing joints.

  20. Failure study of helium-cooled tungsten divertor plasma-facing units tested at DEMO relevant steady-state heat loads

    Ritz, G.; Hirai, T.; Norajitra, P.; Reiser, J.; Giniyatulin, R.; Makhankov, A.; Mazul, I.; Pintsuk, G.; Linke, J.

    2009-12-01

    Tungsten was selected as armor material for the helium-cooled divertor in future DEMO-type fusion reactors and fusion power plants. After realizing the design and testing of them under cyclic thermal loads of up to ~14 MW m-2, the tungsten divertor plasma-facing units were examined by metallography; they revealed failures such as cracks at the thermal loaded and as-machined surfaces, as well as degradation of the brazing layers. Furthermore, in order to optimize the machining processes, the quality of tungsten surfaces prepared by turning, milling and using a diamond cutting wheel were examined. This paper presents a metallographic examination of the tungsten plasma-facing units as well as technical studies and the characterization on machining of tungsten and alternative brazing joints.

  1. WASTE HEAT RECOVERY IN HEAT PUMP SYSTEMS: SOLUTION TO REDUCE GLOBAL WARMING

    Y. Baradey

    2015-11-01

    Full Text Available Energy conversion technologies, where waste heat recovery systems are included, have received significant attention in recent years due to reasons that include depletion of fossil fuel, increasing oil prices, changes in climatic conditions, and global warming. For low temperature applications, there are many sources of thermal waste heat, and several recovery systems and potential useful applications have been proposed by researchers [1-4]. In addition, many types of equipment are used to recover waste thermal energy from different systems at low, medium, and high temperature applications, such as heat exchangers, waste heat recovery boiler, thermo-electric generators, and recuperators. In this paper, the focus is on waste heat recovery from air conditioners, and an efficient application of these energy resources. Integration of solar energy with heat pump technologies and major factors that affect the feasibility of heat recovery systems have been studied and reviewed as well. KEYWORDS: waste heat recovery; heat pump.

  2. Ethical dilemma of recovering organs before donor death.

    Khalid, Umair; Khalil, Sarwat

    2011-08-01

    Organ transplant has had a momentous effect in improving global health over the years. However, there exists a sizeable discrepancy between the supply and demand of organs, especially in developing countries, where lack of expertise, financial constraints, and inadequate transplant facilities have been obstacles. According to current practice, donors must be dead before unpaired vital organs can be recovered. Equal health warrants needs-based health care for everyone. Recovering viable organs from donors while they are alive, but with death inevitable, may be significant to persons on waiting lists. Future policies in organ transplantation must be made after thorough consideration of all aspects of donation and dealing with the inequalities of health care. These pose a challenge for medicolegal and ethical organizations.

  3. Recovering and recycling uranium used for production of molybdenum-99

    Reilly, Sean Douglas; May, Iain; Copping, Roy; Dale, Gregory Edward

    2017-12-12

    A processes for recycling uranium that has been used for the production of molybdenum-99 involves irradiating a solution of uranium suitable for forming fission products including molybdenum-99, conditioning the irradiated solution to one suitable for inducing the formation of crystals of uranyl nitrate hydrates, then forming the crystals and a supernatant and then separating the crystals from the supernatant, thus using the crystals as a source of uranium for recycle. Molybdenum-99 is recovered from the supernatant using an adsorbent such as alumina. Another process involves irradiation of a solid target comprising uranium, forming an acidic solution from the irradiated target suitable for inducing the formation of crystals of uranyl nitrate hydrates, then forming the crystals and a supernatant and then separating the crystals from the supernatant, thus using the crystals as a source of uranium for recycle. Molybdenum-99 is recovered from the supernatant using an adsorbent such as alumina.

  4. Recovering from conflict in romantic relationships: a developmental perspective.

    Salvatore, Jessica E; Kuo, Sally I-Chun; Steele, Ryan D; Simpson, Jeffry A; Collins, W Andrew

    2011-03-01

    This study adopted a developmental perspective on recovery from conflict in romantic relationships. Participants were 73 young adults (target participants), studied since birth, and their romantic partners. A novel observational coding scheme was used to evaluate each participant's degree of conflict recovery, operationalized as the extent to which the participant disengaged from conflict during a 4-min "cool-down" task immediately following a 10-min conflict discussion. Conflict recovery was systematically associated with developmental and dyadic processes. Targets who were rated as securely attached more times in infancy recovered from conflict better, as did their romantic partners. Concurrently, having a romantic partner who displayed better recovery predicted more positive relationship emotions and greater relationship satisfaction. Prospectively, target participants' early attachment security and their partners' degree of conflict recovery interacted to predict relationship stability 2 years later, such that having a partner who recovered from conflict better buffered targets with insecure histories.

  5. The susceptible-infected-recovered (SIR) model for viral marketing

    Ismail, Siti Suhaila; Akil, Ku Azlina Ku; Chulan, Majdah; Sharif, Noorzila

    2017-11-01

    Viral marketing is a marketing strategy utilizes social media to spread information about a product or services provided. It is the most powerful way to share information in a short amount of time. The objective of this study is to investigate the dynamic of viral marketing within a time duration in the point of view of mathematics. This study used the epidemiological model known as Susceptible-Infected-Recovered (SIR). The model consists of a system of three differential equations with three state variables namely susceptible (S), infected (I) and recovered (R). It considers a case of SIR model with demography. Numerical experiments have been performed. The results show that viral marketing reaches its peak within two days. The online messages shared will become higher if the initial number of the infected individual has been increased.

  6. Quality standards and requirements for solid recovered fuels: a review.

    Flamme, Sabine; Geiping, Julia

    2012-04-01

    The utilization of solid recovered fuels (SRF) for energy recovery has been increasing steadily in recent years, and this development is set to continue. In order to use SRF efficiently, it is necessary to define quality standards and introduce targeted quality assurance measures. SRF can be used both in mono-incineration and in co-incineration systems, for instance in power generation and cement plants; but as quality requirements differ, it is necessary to unambiguously define the term 'solid recovered fuel'. The purpose of this article is to provide an overview of the origin, development and the current status of quality assurance for SRF. The basic principles of quality assurance for SRF are explained with reference to the development of the German RAL Quality Assurance System and in addition specifications that have emerged from European standardization work of CEN/TC 343 are analysed.

  7. Heat pumps

    Brodowicz, Kazimierz; Wyszynski, M L; Wyszynski

    2013-01-01

    Heat pumps and related technology are in widespread use in industrial processes and installations. This book presents a unified, comprehensive and systematic treatment of the design and operation of both compression and sorption heat pumps. Heat pump thermodynamics, the choice of working fluid and the characteristics of low temperature heat sources and their application to heat pumps are covered in detail.Economic aspects are discussed and the extensive use of the exergy concept in evaluating performance of heat pumps is a unique feature of the book. The thermodynamic and chemical properties o

  8. Process for recovering tritium from molten lithium metal

    Maroni, Victor A.

    1976-01-01

    Lithium tritide (LiT) is extracted from molten lithium metal that has been exposed to neutron irradiation for breeding tritium within a thermonuclear or fission reactor. The extraction is performed by intimately contacting the molten lithium metal with a molten lithium salt, for instance, lithium chloride - potassium chloride eutectic to distribute LiT between the salt and metal phases. The extracted tritium is recovered in gaseous form from the molten salt phase by a subsequent electrolytic or oxidation step.

  9. Optimization of heat pump using fuzzy logic and genetic algorithm

    Sahin, Arzu Sencan [Sueleyman Demirel University, Technology Faculty, Isparta (Turkey); Kilic, Bayram; Kilic, Ulas [Bucak Emin Guelmez Vocational School, Mehmet Akif Ersoy University, Bucak (Turkey)

    2011-12-15

    Heat pumps offer economical alternatives of recovering heat from different sources for use in various industrial, commercial and residential applications. In this study, single-stage air-source vapor compression heat pump system has been optimized using genetic algorithm (GA) and fuzzy logic (FL). The necessary thermodynamic properties for optimization were calculated by FL. Thermodynamic properties obtained with FL were compared with actual results. Then, the optimum working conditions of heat pump system were determined by the GA. (orig.)

  10. Methods for recovering precious metals from industrial waste

    Canda, L.; Heput, T.; Ardelean, E.

    2016-02-01

    The accelerated rate of industrialization increases the demand for precious metals, while high quality natural resources are diminished quantitatively, with significant operating costs. Precious metals recovery can be successfully made from waste, considered to be secondary sources of raw material. In recent years, concerns and interest of researchers for more increasing efficient methods to recover these metals, taking into account the more severe environmental protection legislation. Precious metals are used in a wide range of applications, both in electronic and communications equipment, spacecraft and jet aircraft engines and for mobile phones or catalytic converters. The most commonly recovered precious metals are: gold from jewellery and electronics, silver from X- ray films and photographic emulsions, industrial applications (catalysts, batteries, glass/mirrors), jewellery; platinum group metals from catalytic converters, catalysts for the refining of crude oil, industrial catalysts, nitric acid manufacturing plant, the carbon-based catalyst, e-waste. An important aspect is the economic viability of recycling processes related to complex waste flows. Hydrometallurgical and pyrometallurgical routes are the most important ways of processing electrical and electronic equipment waste. The necessity of recovering precious metals has opened new opportunities for future research.

  11. Recovering low-turbidity cutting liquid from silicon slurry waste.

    Tsai, Tzu-Hsuan; Shih, Yu-Pei

    2014-04-30

    In order to recover a low-turbidity polyalkylene glycol (PAG) liquid from silicon slurry waste by sedimentation, temperatures were adjusted, and acetone, ethanol or water was used as a diluent. The experimental results show that the particles in the waste would aggregate and settle readily by using water as a diluent. This is because particle surfaces had lower surface potential value and weaker steric stabilization in PAG-water than in PAG-ethanol or PAG-acetone solutions. Therefore, water is the suggested diluent for recovering a low-turbidity PAG (sedimentation. After 50 wt.% water-assisted sedimentation for 21 days, the solid content of the upper liquid reduced to 0.122 g/L, and the turbidity decreased to 44 NTU. The obtained upper liquid was then vacuum-distillated to remove water. The final recovered PAG with 0.37 NTU had similar viscosity and density to the unused PAG and could be reused in the cutting process. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. A novel process for recovering valuable metals from waste nickel-cadmium batteries.

    Huang, Kui; Li, Jia; Xu, Zhenming

    2009-12-01

    The environment is seriously polluted due to improper and inefficient recycling of waste nickel-cadmium (Ni-Cd) batteries in China. The aim of this work is aimed to seek an environmentally friendly recycling process for resolving the negative impacts on environmental and human health resulting from waste Ni-Cd batteries. This work investigates the fundamentals of waste Ni-Cd batteries recycling through vacuum metallurgy separation (VMS) and magnetic separation (MS). The results obtained demonstrate that the optimal temperature, the addition of carbon powder, and heating time in VMS are 1023 K, 1 wt %, 1.5 h, respectively. More than 99.2 wt % Cd is recovered under the optimal experimental condition, and the Cd purity is 99.98%. Around 98.0 wt % ferromagnetic materials are recovered through MS under 60 rpm rotational speed and the recovery ratios of Fe, Ni and Co are 99.2 wt %, 96.1 wt %, and 86.4 wt %, respectively. The composition of ferromagnetic fractions in the residue after VMS increases from 82.3 to 99.6%. Based on these results, a process (including dismantling and crushing, VMS and MS) for recycling of waste Ni-Cd batteries is proposed. This novel process provides a possibility for recycling waste Ni-Cd batteries in a large industrial scale.

  13. Novel approach to recover cobalt and lithium from spent lithium-ion battery using oxalic acid.

    Zeng, Xianlai; Li, Jinhui; Shen, Bingyu

    2015-09-15

    With the booming of consumer electronics (CE) and electric vehicle (EV), a large number of spent lithium-ion battery (LIBs) have been generated worldwide. Resource depletion and environmental concern driven from the sustainable industry of CE and EV have motivated spent LIBs should be recovered urgently. However, the conventional process combined with leaching, precipitating, and filtering was quite complicated to recover cobalt and lithium from spent LIBs. In this work, we developed a novel recovery process, only combined with oxalic acid leaching and filtering. When the optimal parameters for leaching process is controlled at 150 min retention time, 95 °C heating temperature, 15 g L(-1) solid-liquid ratio, and 400 rpm rotation rate, the recovery rate of lithium and cobalt from spent LIBs can reach about 98% and 97%, respectively. Additionally, we also tentatively discovered the leaching mechanism of lithium cobalt oxide (LiCoO2) using oxalic acid, and the leaching order of the sampling LiCoO2 of spent LIBs. All the obtained results can contribute to a short-cut and high-efficiency process of spent LIBs recycling toward a sound closed-loop cycle. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Effectiveness of heating, ventilation and air conditioning system with HEPA filter unit on indoor air quality and asthmatic children's health

    Xu, Ying; Raja, Suresh; Ferro, Andrea R.; Jaques, Peter A.; Hopke, Philip K. [Clarkson University, 8 Clarkson Avenue, Center for Air Resources Engineering and Science, Potsdam, NY 13699 (United States); Gressani, Cheryl; Wetzel, Larry E. [Air Innovations, Inc, 7000 Performance Drive, North Syracuse, NY 13212 (United States)

    2010-02-15

    Poor indoor air quality has been linked to the exacerbation of asthma symptoms in children. Because people spend most of their time indoors, improving indoor air quality may provide some relief to asthma sufferers. A study was conducted to assess whether operating an air cleaning/ventilating unit (HEPAiRx {sup registered}) in a child's bedroom can improve his/her respiratory health. Thirty children diagnosed with asthma were randomly split into two groups. For the first six weeks, group A had the air cleaning/ventilating unit (HEPAiRx {sup registered}) running in the bedrooms of the participants and group B did not; for the second six weeks, both groups had the cleaners running in the bedrooms; and, for the final six weeks, group A turned the cleaners off and group B kept theirs running. Indoor air quality parameters, including temperature, relative humidity, particulate matter (PM 0.5-10 {mu}m), carbon monoxide, carbon dioxide and total volatile organic compound (TVOC) concentrations, were monitored in each bedroom using an AirAdvice indoor air quality multi-meter. As a measure of pulmonary inflammation, exhaled breath condensate (EBC) was collected every sixth day and analyzed for nitrate and pH. Peak expiratory flow (PEF) was also measured. PM and TVOC concentrations decreased with operation of the HEPAiRx an average of 72% and 59%, respectively. The EBC nitrate concentrations decreased significantly and the EBC pH and PEF values increased significantly with operation of the unit (p < 0.001 when comparing on/off sample means). These results indicate that air cleaning in combination with ventilation can effectively reduce symptoms for asthma sufferers. (author)

  15. Heat Capacity Analysis Report

    Findikakis, A.

    2004-01-01

    The purpose of this report is to provide heat capacity values for the host and surrounding rock layers for the waste repository at Yucca Mountain. The heat capacity representations provided by this analysis are used in unsaturated zone (UZ) flow, transport, and coupled processes numerical modeling activities, and in thermal analyses as part of the design of the repository to support the license application. Among the reports that use the heat capacity values estimated in this report are the ''Multiscale Thermohydrologic Model'' report, the ''Drift Degradation Analysis'' report, the ''Ventilation Model and Analysis Report, the Igneous Intrusion Impacts on Waste Packages and Waste Forms'' report, the ''Dike/Drift Interactions report, the Drift-Scale Coupled Processes (DST and TH Seepage) Models'' report, and the ''In-Drift Natural Convection and Condensation'' report. The specific objective of this study is to determine the rock-grain and rock-mass heat capacities for the geologic stratigraphy identified in the ''Mineralogic Model (MM3.0) Report'' (BSC 2004 [DIRS 170031], Table 1-1). This report provides estimates of the heat capacity for all stratigraphic layers except the Paleozoic, for which the mineralogic abundance data required to estimate the heat capacity are not available. The temperature range of interest in this analysis is 25 C to 325 C. This interval is broken into three separate temperature sub-intervals: 25 C to 95 C, 95 C to 114 C, and 114 C to 325 C, which correspond to the preboiling, trans-boiling, and postboiling regimes. Heat capacity is defined as the amount of energy required to raise the temperature of a unit mass of material by one degree (Nimick and Connolly 1991 [DIRS 100690], p. 5). The rock-grain heat capacity is defined as the heat capacity of the rock solids (minerals), and does not include the effect of water that exists in the rock pores. By comparison, the rock-mass heat capacity considers the heat capacity of both solids and pore

  16. Neutron activation analysis of maltenes recovered from EUROBITUM simulates

    Impens, N

    2006-01-01

    According to the present Belgian reference scenario, Eurobitum bituminised radioactive waste has to be disposed off in a deep underground repository in a stable geological formation such as Boom Clay. This waste originated mainly from mixtures of nuclear fuel decladding slurries and waste concentrates from the nuclear fuel cycle. Even though safety assessment studies up till present do not show that this waste is unacceptable for deep underground disposal, a final decision about the disposal of the bituminised waste has not been taken so far, and alternative solutions are still conceivable. To support the decision-making we investigate methods to recondition this bituminised waste. We continued studying a room temperature re-treatment method for Eurobitum. The aim of the method is the stabilisation and minimisation of final waste, and the free release of recovered materials. The method comprises the recovery of maltenes and water soluble salts. The recovery of maltenes is performed by dissolving the complete bitumen matrix with a 'solvent', followed by the precipitation of the asphaltenes by addition of a so-called 'nonsolvent'. The 'solvent' is a 50 percent aromatic blend of Shellsol A150 and Shellsol H, whereas the 'nonsolvent' is aliphatic Shellsol T. The recovered maltenes represent 40 % wt of the waste, as shown in the inner pie chart. Part of the maltenes could not be recovered and remain in the asphaltene matrix, as can be seen from the difference between the inner and outer pie chart, representing the real composition and the weight fractions after separation, respectively. A second step of the room temperature re-treatment method covers the complete removal of the water soluble (nitrate) salts, and is described in the main reference and references therein. Application of the room temperature re-treatment method results in a final waste that consists of water insoluble salts embedded in an asphaltene matrix which is less sensitive towards radiolysis than

  17. Heat transfer

    Saad, M.A.

    1985-01-01

    Heat transfer takes place between material systems as a result of a temperature difference. The transmission process involves energy conversions governed by the first and second laws of thermodynamics. The heat transfer proceeds from a high-temperature region to a low-temperature region, and because of the finite thermal potential, there is an increase in entropy. Thermodynamics, however, is concerned with equilibrium states, which includes thermal equilibrium, irrespective of the time necessary to attain these equilibrium states. But heat transfer is a result of thermal nonequilibrium conditions, therefore, the laws of thermodynamics alone cannot describe completely the heat transfer process. In practice, most engineering problems are concerned with the rate of heat transfer rather than the quantity of heat being transferred. Resort then is directed to the particular laws governing the transfer of heat. There are three distinct modes of heat transfer: conduction, convection, and radiation. Although these modes are discussed separately, all three types may occur simultaneously

  18. Microbial investigation of biofilms recovered from endotracheal tubes using sonication in intensive care unit pediatric patients

    Thiago de Oliveira Ferreira

    2016-09-01

    Conclusions: Our study demonstrated that sonication technique can be applied to ET biofilms to identify microorganisms attached to their surface with a great variety of species identified. However, we did not find significant differences in comparison with the traditional tracheal aspirate culture approach.

  19. Recovering value from beef carcasses classified as dark cutters by United States Department of Agriculture graders.

    Bass, P D; Scanga, J A; Chapman, P L; Smith, G C; Tatum, J D; Belk, K E

    2008-07-01

    Effects of the dark-cutting condition were examined on commercially slaughtered beef carcass sides that were classified into groups exhibiting 1/3, 1/2, and full degrees of the dark-cutting (DEGDC) condition, as evaluated by a USDA-Agricultural Marketing Service grader (n = 20 per group). Twenty-nine muscles of each carcass side were evaluated to determine the ultimate pH and color (L*, a*, and b*). Fourteen beef muscles (biceps femoris, deep pectoral, chuck complexus, gluteus medius, infraspinatus, latissimus dorsi, psoas major, longissimus thoracis, longissimus lumborum, semimembranosus, semitendinosus, triceps brachii long head, tensor fasciae latae, and vastus lateralis) were evaluated using Warner-Bratzler Shear force (WBSF) and a trained sensory panel. The muscle x DEGDC interaction was significant for ultimate pH, L*, a*, and b* values (P sensory panel scores (P > 0.05), but differences were detected among muscles (P sensory scores or WBSF between DEGDC classes suggested equal sensory expectations for muscles from dark-cutting carcasses.

  20. Heat exchanger

    Daman, Ernest L.; McCallister, Robert A.

    1979-01-01

    A heat exchanger is provided having first and second fluid chambers for passing primary and secondary fluids. The chambers are spaced apart and have heat pipes extending from inside one chamber to inside the other chamber. A third chamber is provided for passing a purge fluid, and the heat pipe portion between the first and second chambers lies within the third chamber.

  1. Assessing the impacts of droughts and heat waves at thermoelectric power plants in the United States using integrated regression, thermodynamic, and climate models

    Margaret A. Cook

    2015-11-01

    Full Text Available Recent droughts and heat waves have revealed the vulnerability of some power plants to effects from higher temperature intake water for cooling. In this evaluation, we develop a methodology for predicting whether power plants are at risk of violating thermal pollution limits. We begin by developing a regression model of average monthly intake temperatures for open loop and recirculating cooling pond systems. We then integrate that information into a thermodynamic model of energy flows within each power plant to determine the change in cooling water temperature that occurs at each plant and the relationship of that water temperature to other plants in the river system. We use these models together with climate change models to estimate the monthly effluent temperature at twenty-six power plants in the Upper Mississippi River Basin and Texas between 2015 and 2035 to predict which ones are at risk of reaching thermal pollution limits. The intake model shows that two plants could face elevated intake temperatures between 2015 and 2035 compared to the 2010–2013 baseline. In general, a rise in ambient cooling water temperature of 1 °C could cause a drop in power output of 0.15%–0.5%. The energy balance shows that twelve plants might exceed state summer effluent limits.

  2. A combination of Stirling engine and high-efficiency boiler. Microsize cogeneration unit for heat and power supply; Stirlingmotor und Brennwertkessel vereint. Mikro-Waermekraftkopplung liefert Strom und Waerme

    Donnerbauer, R.

    2001-03-01

    Apart from the heat pump and fuel cell, there is another new development: At the ISH in March, the Dutch producer EnAtEc intends to present a microsize cogeneration unit consisting of a gas-fuelled high-efficiency boiler and a free-piston Stirling motor. [German] Sind die Wirkungsgrade in der Heiztechnik ausgenutzt? Auf die Frage 'Was kommt nach der Brennwerttechnik?' gibt es jetzt neben Waermepumpe und Brennstoffzelle eine neue Antwort. Zur kommenden ISH Ende Maerz hat die niederlaendische Firma EnAtEc die Vorstellung einer 'Mikro-Waermekraftkopplung' ({mu}WK) angekuendigt. Das Geraet kombiniert einen Gas-Brennwertkessel mit einer Freikolben-Stirlingmaschine. (orig.)

  3. Thermal construction unit activation with supply air gains significance. Ceilings cooling - supply air heating - more than 50 % energy conservation; Thermische Bauteilaktivierung mit Zuluft gewinnt an Bedeutung. Decke kuehlen - Zuluft erwaermen - mehr als 50% Energie einsparen

    Schmid, Wolfgang

    2009-05-15

    In the year 2001, in Stuttgart (Federal Republic of Germany) the first office building was established which uses a thermal construction unit activation with air as cooling agent. Today, the system ''Concret-cool'' already is installed in more than 40 buildings. Computations show that due to the room heating by means of internally finned ventilation pipes embedded in concrete more than 50 % less energy in comparison to comparable systems can be used. In his Green Building project ''Skyline Tower'' in Munich (Federal Republic of Germany), also star architect Helmut Jahn uses the know-how of the manufacturer of ventilation systems from Stuttgart. As one of the first multi-storied buildings in Munich, ''Skyline Tower'' with its 23 floors was prized with the pre-certificate of the German quality seal ''sustainable building ''in gold.

  4. Ingot formation using uranium dendrites recovered by electrolysis in LiCl-KCl-PuCl3-UCl3 melt

    Mineo Fukushima; Akira Nakayoshi; Shinichi Kitawaki; Masaki Kurata; Noboru Yahagi

    2008-01-01

    Products on solid cathodes recovered by the metal pyrochemical processing were processed to obtain uranium ingot. Studies on process conditions of uranium formation, assay recovered uranium products and by-products and evaluation of mass balance were carried out. In these tests, it is confirmed that uranium ingots can be obtained with heating the products more than melting temperature of metal uranium under atmospheric pressure because adhered salt cover the uranium not to oxidize it during uranium cohering. Covered salt can be removed after ingot formation. Inside the ingot, there were a lump of uranium and dark brown colored dross was observed. Material balance of uranium is 77 ∼ 96%, that of plutonium is 71 ∼ 109%, and that of americium that is a volatile substance more than uranium and plutonium become 79 ∼ 119%. Volatilization of americium is very small under the condition of high temperature. (authors)

  5. The United States of America Country Update

    Lund, John W. (1); Bloomquist, R. Gordon (2); Boyd, Tonya L. (1); Renner, Joel (3); (1) Geo-Heat Center, Oregon Institute of Technology, Klamath Falls, OR; (2) Washington State University Energy Program, Olympia, WA; (3) Idaho National Engineering and Environmental Laboratory, Idaho Falls, ID

    0001-01-01

    Geothermal energy is used for electric power generation and direct utilization in the United States. The present installed capacity (gross) for electric power generation is 2,534 MWe with about 2,000 MWe net delivering power to the grid producing approximately 17,840 GWh per year for a 80.4% gross capacity factor. Geothermal electric power plants are located in California, Nevada, Utah and Hawaii. The two largest concentrations of plants are at The Geysers in northern California and the Imperial Valley in southern California. The latest development at The Geysers, starting in 1998, is injecting recycled wastewater from two communities into the reservoir, which presently has recovered about 100 MWe of power generation. The second pipeline from the Santa Rosa area has just come on line. The direct utilization of geothermal energy includes the heating of pools and spas, greenhouses and aquaculture facilities, space heating and district heating, snow melting, agricultural drying, industrial applications and groundsource heat pumps. The installed capacity is 7,817 MWt and the annual energy use is about 31,200 TJ or 8,680 GWh. The largest application is ground-source (geothermal) heat pumps (69% of the energy use), and the next largest direct-uses are in space heating and agricultural drying. Direct utilization (without heat pumps) is increasing at about 2.6% per year; whereas electric power plant development is almost static, with only about 70 MWe added since 2000 (there were errors in the WGC2000 tabulation). A new 185-MWe plant being proposed for the Imperial Valley and about 100 MWe for Glass Mountain in northern California could be online by 2007-2008. Several new plants are proposed for Nevada totaling about 100 MWe and projects have been proposed in Idaho, New Mexico, Oregon and Utah. The total planned in the next 10 years is 632 MWe. The energy savings from electric power generation, direct-uses and ground-source heat pumps amounts to almost nine million tonnes

  6. The United States of America Country Update

    Lund, John W [1; Bloomquist, R Gordon [2; Boyd, Tonya L [1; Renner, Joel [3; (1) Geo-Heat Center, Oregon Institute of Technology, Klamath Falls, OR; (2) Washington State University Energy Program, Olympia, WA; (3) Idaho National Engineering and Environmental Laboratory, Idaho Falls, ID

    0000-12-30

    Geothermal energy is used for electric power generation and direct utilization in the United States. The present installed capacity (gross) for electric power generation is 2,534 MWe with about 2,000 MWe net delivering power to the grid producing approximately 17,840 GWh per year for a 80.4% gross capacity factor. Geothermal electric power plants are located in California, Nevada, Utah and Hawaii. The two largest concentrations of plants are at The Geysers in northern California and the Imperial Valley in southern California. The latest development at The Geysers, starting in 1998, is injecting recycled wastewater from two communities into the reservoir, which presently has recovered about 100 MWe of power generation. The second pipeline from the Santa Rosa area has just come on line. The direct utilization of geothermal energy includes the heating of pools and spas, greenhouses and aquaculture facilities, space heating and district heating, snow melting, agricultural drying, industrial applications and groundsource heat pumps. The installed capacity is 7,817 MWt and the annual energy use is about 31,200 TJ or 8,680 GWh. The largest application is ground-source (geothermal) heat pumps (69% of the energy use), and the next largest direct-uses are in space heating and agricultural drying. Direct utilization (without heat pumps) is increasing at about 2.6% per year; whereas electric power plant development is almost static, with only about 70 MWe added since 2000 (there were errors in the WGC2000 tabulation). A new 185-MWe plant being proposed for the Imperial Valley and about 100 MWe for Glass Mountain in northern California could be online by 2007-2008. Several new plants are proposed for Nevada totaling about 100 MWe and projects have been proposed in Idaho, New Mexico, Oregon and Utah. The total planned in the next 10 years is 632 MWe. The energy savings from electric power generation, direct-uses and ground-source heat pumps amounts to almost nine million tonnes

  7. The United States of America country update

    Lund, John W.; Bloomquist, R. Gordon; Boyd, Tonya L.; Renner, Joel

    2005-01-01

    Geothermal energy is used for electric power generation and direct utilization in the United States. The present installed capacity (gross) for electric power generation is 2,534 MWe with about 2,000 MWe net delivering power to the grid producing approximately 17,840 GWh per year for a 80.4% gross capacity factor. Geothermal electric power plants are located in California, Nevada, Utah and Hawaii. The two largest concentrations of plants are at The Geysers in northern California and the Imperial Valley in southern California. The latest development at The Geysers, starting in 1998, is injecting recycled wastewater from two communities into the reservoir, which presently has recovered about 100 MWe of power generation. The second pipeline from the Santa Rosa area has just come on line. The direct utilization of geothermal energy includes the heating of pools and spas, greenhouses and aquaculture facilities, space heating and district heating, snow melting, agricultural drying, industrial applications and groundsource heat pumps. The installed capacity is 7,817 MWt and the annual energy use is about 31,200 TJ or 8,680 GWh. The largest application is ground-source (geothermal) heat pumps (69% of the energy use), and the next largest direct-uses are in space heating and agricultural drying. Direct utilization (without heat pumps) is increasing at about 2.6% per year; whereas electric power plant development is almost static, with only about 70 MWe added since 2000 (there were errors in the WGC2000 tabulation). A new 185-MWe plant being proposed for the Imperial Valley and about 100 MWe for Glass Mountain in northern California could be online by 2007-2008. Several new plants are proposed for Nevada totaling about 100 MWe and projects have been proposed in Idaho, New Mexico, Oregon and Utah. The total planned in the next 10 years is 632 MWe. The energy savings from electric power generation, direct-uses and ground-source heat pumps amounts to almost nine million tonnes

  8. Reduction of energy cost and CO2 emission for the furnace using energy recovered from waste tail-gas

    Jou, Chih-Ju G.; Wu, Chung-Rung; Lee, Chien-Li

    2010-01-01

    In this research, the waste tail gas emitted from petrochemical processes, e.g. catalytic reforming unit, catalytic cracking unit and residue desulfurization unit, was recovered and reused as a replacement of natural gas (NG). On-site experimental results show that both the flame length and orange-yellowish brightness decrease with more proportion of waste gas fuel added to the natural gas, and that the adiabatic temperature of the mixed fuel is greater than 1800 o C. A complete replacement of natural gas by the recovered waste gas fuel will save 5.8 x 10 6 m 3 of natural gas consumption, and 3.5 x 10 4 tons of CO 2 emission annually. In addition, the reduction of residual O 2 concentration in flue gases from 4% to 3% will save 1.1 x 10 6 m 3 of natural gas consumption, reduce 43.0% of NO x emission, and 1.3 x 10 3 tons of CO 2 emission annually. Thus, from the viewpoint of the overall economics and sustainable energy policy, recovering the waste tail gas energy as an independent fuel source to replace natural gas is of great importance for saving energy, reducing CO 2 emission reduction, and lowering environmental impact.

  9. Temperature ranges of the application of air-to-air heat recovery ventilator in supermarkets in winter, China

    Kang, Yanming; Wang, Youjun; Zhong, Ke [School of Environmental Science and Engineering, Donghua University, Shanghai 201620 (China); Liu, Jiaping [School of Architecture, Xi' an University of Architecture and Technology, Xi' an 710055 (China)

    2010-12-15

    Energy consumption is an important issue in China. In heating, ventilation and air conditioning (HVAC) systems, more and more commercial buildings use air-to-air heat recovery ventilators as energy saving units for recovering heat from the exhaust air in ventilation systems in current years. In the present paper, critical temperatures of air-to-air heat recovery systems for supermarkets in winter are recommended and discussed for the four cities in different climate zones of China. The analysis shows that the temperature of fresh air in winter can be categorized into three regions, i.e., recovery region, transition region and impermissible recovery region. The results also indicate that the latent heat recovery is not suitable for ventilation energy savings in supermarkets in winter. Meanwhile, the applicability of sensible heat recovery in supermarkets depends on outdoor climate and fresh air flow rate. If a variable rotational speed fan is used to introduce fresh air into the building, heat recovery does always function as planned in winter for all the selected cities except Guangzhou, and most values of the COP are much higher than 2.5. Otherwise, there is the risk of negative impact on building energy savings in all cities except Harbin. (author)

  10. Loss of vital ac power and the residual heat removal system during mid-loop operations at Vogtle Unit 1 on March 20, 1990

    1990-06-01

    On March 20, 1990, the Vogtle Electric Generating Plant Unit 1, located in Burke County, Georgia, about 25 miles southeast of Augusta, experienced a loss of all safety (vital) ac power. The plant was in cold shutdown with reactor coolant level lowered to ''mid-loop'' for various maintenance tasks. Both the containment building personnel hatch and equipment hatch were open. One emergency diesel generator and one reserve auxiliary transformer were out of service for maintenance, with the remaining reserve auxiliary transformer supplying both Unit 1 safety buses. A truck in the low voltage switchyard backed into the support column for an offsite power feed to the reserve auxiliary transformer which was supplying safety power. The insulator broke, a phase-to-ground fault occurred, and the feeder circuit breakers for the safety buses opened. The operable emergency diesel generator started automatically because of the undervoltage condition on the safety bus, but tripped off after about 1 minute. About 20 minutes later the diesel generator load sequencer was reset, causing the diesel generator to start a second time. The diesel generator operated for about 1 minute, and tripped off. The diesel generator was restarted in the manual emergency mode 36 minutes after the loss of power. The generator remained on line and provided power to its safety bus. During the 36 minutes without safety bus power, the reactor coolant system temperature rose from about 90 degree F to 136 degree F. This report documents the results of an Incident Investigation Team sent to Vogtle by the Executive Director for Operations of the US Nuclear Regulatory Commission to determine what happened, identify the probable causes, and make appropriate findings and conclusions. 79 figs., 16 tabs

  11. Heat pipe

    Triggs, G.W.; Lightowlers, R.J.; Robinson, D.; Rice, G.

    1986-01-01

    A heat pipe for use in stabilising a specimen container for irradiation of specimens at substantially constant temperature within a liquid metal cooled fast reactor, comprises an evaporator section, a condenser section, an adiabatic section therebetween, and a gas reservoir, and contains a vapourisable substance such as sodium. The heat pipe further includes a three layer wick structure comprising an outer relatively fine mesh layer, a coarse intermediate layer and a fine mesh inner layer for promoting unimpeded return of condensate to the evaporation section of the heat pipe while enhancing heat transfer with the heat pipe wall and reducing entrainment of the condensate by the upwardly rising vapour. (author)

  12. Towards an intermittency-friendly energy system: Comparing electric boilers and heat pumps in distributed cogeneration

    Blarke, Morten B.

    2012-01-01

    Highlights: ► We propose an “intermittency-friendly” energy system design. ► We compare intermittency-friendly concepts in distributed cogeneration. ► We investigate a new concept involving a heat pump and intermediate cold storage. ► We find significant improvements in operational intermittency-friendliness. ► Well-designed heat pump concepts are more cost-effective than electric boilers. -- Abstract: Distributed cogeneration has played a key role in the implementation of sustainable energy policies for three decades. However, increasing penetration levels of intermittent renewables is challenging that position. The paradigmatic case of West Denmark indicates that distributed operators are capitulating as wind power penetration levels are moving above 25%; some operators are retiring cogeneration units entirely, while other operators are making way for heat-only boilers. This development is jeopardizing the system-wide energy, economic, and environmental benefits that distributed cogeneration still has to offer. The solution is for distributed operators to adapt their technology and operational strategies to achieve a better co-existence between cogeneration and wind power. Four options for doing so are analysed including a new concept that integrates a high pressure compression heat pump using low-temperature heat recovered from flue gasses in combination with an intermediate cold storage, which enables the independent operation of heat pump and cogenerator. It is found that an electric boiler provides consistent improvements in the intermittency-friendliness of distributed cogeneration. However, well-designed heat pump concepts are more cost-effective than electric boilers, and in future markets where the gas/electricity price ratio is likely to increase, compression heat pumps in combination with intermediate thermal storages represent a superior potential for combining an intermittency-friendly pattern of operation with the efficient use of

  13. Process integration study of a kraft pulp mill converted to an ethanol production plant – Part A: Potential for heat integration of thermal separation units

    Fornell, Rickard; Berntsson, Thore

    2012-01-01

    Energy efficiency is an important parameter for the profitability of biochemical ethanol production from lignocellulosic raw material. The yield of ethanol is generally low due to the limited amount of fermentable compounds in the raw material. Increasing energy efficiency leads to possibilities of exporting more by-products, which in turn might reduce the net production cost of ethanol. Energy efficiency is also an important issue when discussing the repurposing of kraft pulp mills to biorefineries, since the mills in question most likely will be old and inefficient. Investing in energy efficiency measures might therefore have a large effect on the economic performance. This paper discusses energy efficiency issues related to the repurposing of a kraft pulp mill into a lignocellulosic ethanol production plant. The studied process is a typical Scandinavian kraft pulp mill that has been converted to a biorefinery with ethanol as main product. A process integration study, using pinch analysis and process simulations, has been performed in order to assess alternative measures for improving the energy efficiency. The improvements found have also been related to the possibilities for by-product sales from the plant (electricity and/or lignin). In a forthcoming paper, which is the second part of this process integration study, an economic analysis based on the results from this paper will be presented. - Highlights: ► Conversion of a kraft pulp mill to ethanol production. ► Heat integration of distillation/evaporation in a lignocellulosic ethanol plant. ► Advanced pinch curves used to find new integration possibilities. ► 35–40% reduction of steam demand.

  14. Techno-economic analysis and optimization of the heat recovery of utility boiler flue gas

    Xu, Gang; Huang, Shengwei; Yang, Yongping; Wu, Ying; Zhang, Kai; Xu, Cheng

    2013-01-01

    Highlights: • Four typical flue gas heat recovery schemes are quantitatively analyzed. • The analysis considers thermodynamic, heat transfer and hydrodynamics factors. • Techno-economic analysis and optimization design are carried out. • High-stage steam substitute scheme obtains better energy-saving effect. • Large heat transfer area and high flue gas resistances weaken overall performance. - Abstract: Coal-fired power plants in China consume nearly half of available coals, and the resulting CO 2 emissions cover over 40% of total national emissions. Therefore, reducing the energy expenditure of coal-fired power plants is of great significance to China’s energy security and greenhouse gas reduction programs. For coal-fired power plants, the temperature of a boiler’s exhaust gas reaches 120–150 °C or even higher. The thermal energy of boiler’s exhaust accounts for approximately 3–8% of the total energy of fuel input. Given these factors, we conducted a techno-economic analysis and optimization design of the heat recovery system using boiler exhaust gas. This research is conformed to the principles of thermodynamic, heat transfer, and hydrodynamics. Based on the data from an existing 1000 MW typical power generation unit in China, four typical flue gas heat recovery schemes are quantitatively analyzed from the thermodynamics perspective. The impacts of flue gas heat recovery on net work output and standard coal consumption rate of various schemes are performed. Furthermore, the transfer area of heat recovery exchanger and the draft fan work increment due to the flue gas pressure drop are analyzed. Finally, a techno-economic analysis of the heat recovery schemes is conducted, and some recommendations on optimization design parameters are proposed, with full consideration of various factors such as the decrease on fuel cost due to energy conservation as well as the investment cost of heat recovery retrofitting. The results revealed that, high

  15. Advances in heat pump systems: A review

    Chua, K.J.; Chou, S.K.; Yang, W.M.

    2010-01-01

    Heat pump systems offer economical alternatives of recovering heat from different sources for use in various industrial, commercial and residential applications. As the cost of energy continues to rise, it becomes imperative to save energy and improve overall energy efficiency. In this light, the heat pump becomes a key component in an energy recovery system with great potential for energy saving. Improving heat pump performance, reliability, and its environmental impact has been an ongoing concern. Recent progresses in heat pump systems have centred upon advanced cycle designs for both heat- and work-actuated systems, improved cycle components (including choice of working fluid), and exploiting utilisation in a wider range of applications. For the heat pump to be an economical proposition, continuous efforts need to be devoted to improving its performance and reliability while discovering novel applications. Some recent research efforts have markedly improved the energy efficiency of heat pump. For example, the incorporation of a heat-driven ejector to the heat pump has improved system efficiency by more than 20%. Additionally, the development of better compressor technology has the potential to reduce energy consumption of heat pump systems by as much as 80%. The evolution of new hybrid systems has also enabled the heat pump to perform efficiently with wider applications. For example, incorporating a desiccant to a heat pump cycle allowed better humidity and temperature controls with achievable COP as high as 6. This review paper provides an update on recent developments in heat pump systems, and is intended to be a 'one-stop' archive of known practical heat pump solutions. The paper, broadly divided into three main sections, begins with a review of the various methods of enhancing the performance of heat pumps. This is followed by a review of the major hybrid heat pump systems suitable for application with various heat sources. Lastly, the paper presents novel

  16. Recovering gold from thiosulfate leach pulps via ion exchange

    Nicol, Michael J.; O'Malley, Glen

    2002-10-01

    Increasing environmental and occupational safety concerns about the use of cyanide in gold processing has increased interest in more acceptable alternative lixiviants, the most promising of which is thiosulfate. However, the thiosulfate process lacks a proven inpulp method of recovering the dissolved gold because activated carbon is not effective for the absorption of the gold-thiosulfate complex. This paper describes work aimed at evaluating the effectiveness of commercially available anion exchange resins for the recovery of gold from thiosulfate leach liquors and pulps.

  17. Process for recovering uranium from wet process phosphoric acid (III)

    Pyrih, R.Z.; Rickard, R.S.; Carrington, O.F.

    1983-01-01

    Uranium is conventionally recovered from wet-process phosphoric acid by two liquid ion exchange steps using a mixture of mono- and disubstituted phenyl esters of orthophosphoric acid (OPPA). Efficiency of the process drops as the mono-OPPA is lost preferentially to the aqueous phase. This invention provides a process for the removal of the uranium process organics (OPPA and organic solvents) from the raffinate of the first liquid ion exchange step and their return to the circuit. The process organics are removed by a combination flotation and absorption step, which results in the recovery of the organics on beads of a hydrophobic styrene polymer

  18. A computer-implemented method of recovering a visual event

    2017-01-01

    a synchronization marker at least for a first occurrence of a temporal section classified as a smooth pursuit eye movement; wherein the synchronization marker comprises a link to or impression information of the contents of the viewport at the point in time when the first occurrence of a smooth pursuit eye movement...... occurred; via the synchronization marker, recovering the impression information or the contents of the viewport that was displayed at the point in time when the first occurrence of the smooth pursuit occurred....

  19. Preliminary fee methodology for recovering GTCC-LLW management costs

    Clark, L.L.

    1990-06-01

    The US Department of Energy (DOE) is currently planning a fee to recover costs of managing Greater-Than-Class-C Low-Level Waste (GTCC-LLW). A cash flow basis will be used for fee calculations to ensure recovery of all applicable program costs. Positive cash flows are revenues received from waste generators. Negative cash flows are program expenses for storage, transportation, treatment, and disposal of the wastes and for program development, evaluation, and administration. Program balances are the net result of positive and negative cash flows each year. The methodology calculates fees that will recovery all program expenses taking into account cost inflation. 3 refs., 1 tab

  20. Recovering of thorium contained in wastes from Thorium Purification Plant

    Brandao Filho, D.; Hespanhol, E.C.B.; Baba, S.; Miranda, L.E.T.; Araujo, J.A. de.

    1992-08-01

    A study has been developed in order to establish a chemical process for recovering thorium from wastes produced at the Thorium Purification Plant of the Instituto de Pesquisas Energeticas e Nucleares. The recovery of thorium in this process will be made by means of solvent extraction technique. Solutions of TBP/Varsol were employed as extracting agent during the runs. The influence of thorium concentration in the solution, aqueous phase acidity, volume ratio of the phases, percentage of TBP/Varsol and the contact time of the phases on the extraction of thorium and lanthanides was determined. (author)

  1. Aerobic training in persons who have recovered from juvenile dermatomyositis

    Riisager, M; Mathiesen, P R; Vissing, J

    2013-01-01

    A recent study has shown that 36 persons who had recovered from juvenile dermatomyositis (JDM) have on average an 18% decrease in maximal oxygen uptake. The objective of this study was to investigate the effect of a 12-week aerobic training program in this group, and assess whether aerobic training...... can normalize aerobic capacity to the expected level for age and gender. The patients participating in the study, one male and nine females (16-42years of age), were in remission from JDM, defined as no clinical or biochemical evidence of disease activity and no medical treatment for 1year...

  2. HEAT PUMP USING SUBSOIL WATERS AS LOW TEMPERATURE HEAT SOURCE

    Denysova Alla

    2015-08-01

    Full Text Available One of the basic directions of perfection of heat supply systems is the tendency of transition to the low-temperature heating systems based on application of heat pump installations. We consider heat supply system with heat pump installations using subsoil waters. Numerical simulation of thermal processes in the elements of a single-stage and double-stage heat pump systems has been worked out. Values of depths of wells and their quantity, necessary for effective operation of the offered installations, and values of capacity of electric water pumps for subsoil waters unit are calculated. Capacity of compressor electric drive and coefficient of performance of heat pump for the conditions of the city of Odessa are presented.

  3. Effect of limestone addition on chlorine compound emissions in grate and fluidized-bed combustion of recovered fuels

    Vesterinen, R.; Ruuskanen, J.

    2000-01-01

    The aim was to verify the positive results of laboratory experiments concerning the reducing effect of limestone addition on emissions of organic chlorine compounds and acidifying compounds (HCl, HF, SO 2 ) in grate and fluidized-bed combustion of recovered fuels in commercial boilers. The final aim is to develop a cheap and practical way of reducing emissions of organic chlorine compounds in co-combustion of recovered fuels. Pellets produced from the mixture of recovered fuel and limestone is a product ready for use in plants without any need of additional employees or equipment for limestone feed. Pellets produced by Ewapower Oy are used as recovered fuel and Gotland limestone of Partek Nordkalk Oyj Abp as limestone. Ewapower Oy produces pellets by feeding a certain proportion of limestone among recovered fuel at the production stage. Experiments are carried out in one grate-combustion plant and in one or two fluidized-bed plants. The first experiments were carried out in a 3 MWth BioGrate boiler at the new heating station of Pielavesi municipality in autumn 1999. The flue gases are cleaned with a cyclone (FinCleaner). The main fuel was a mixture of bark and sawdust (3:1) from a sawmill. Ewapower pellets with an addition of Gotland limestone were used as recovered fuel. The experiments were carried out at about 2 MW boiler output. Temperatures of the furnace and flue gas, pressure and fuel gas composition were measured continuously. For determining the composition of gas, O 2 , CO, CO 2 , hydrocarbons and N 2 O(FTIR), NO x and SO 2 were measured continuously. HCl, heavy metals (As, Cd, Cr, Cu, Hg, Ni, Pb, Zn), polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/PCDF), polyaromatic hydrocarbons (PAH), chlorobenzenes, chlorophenols and PCB were measured as one-shot determinations. Fuel and ash samples were also collected during the experiments. The organic compounds were analyzed by the Department of Environmental Science of the University of Kuopio, which is

  4. Chapter 11. Heat Exchangers

    Rafferty, Kevin D.; Culver, Gene

    1998-01-01

    Most geothermal fluids, because of their elevated temperature, contain a variety of dissolved chemicals. These chemicals are frequently corrosive toward standard materials of construction. As a result, it is advisable in most cases to isolate the geothermal fluid from the process to which heat is being transferred. The task of heat transfer from the geothermal fluid to a closed process loop is most often handled by a plate heat exchanger. The two most common types used in geothermal applications are: bolted and brazed. For smaller systems, in geothermal resource areas of a specific character, downhole heat exchangers (DHEs) provide a unique means of heat extraction. These devices eliminate the requirement for physical removal of fluid from the well. For this reason, DHE-based systems avoid entirely the environmental and practical problems associated with fluid disposal. Shell and tube heat exchangers play only a minor role in low-temperature, direct-use systems. These units have been in common use in industrial applications for many years and, as a result, are well understood. For these reasons, shell and tube heat exchangers will not be covered in this chapter.

  5. Heat and fluid flow in accident of Fukushima Daiichi Nuclear Power Plant, Unit 3. Behaviour of high pressure coolant injection system (HPCI) based on thermodynamic model

    Maruyama, Shigenao

    2014-01-01

    In order to clarify the process of Accident of Fukushima Nuclear Plants, an accident scenario of Fukushima Daiichi Nuclear Power Plant, Unit 3 is analyzed from the data open to the public. Phase equilibrium process model was introduced in which the vapor and water are at saturation point in the vessels. The present accident scenario assumes that the high pressure coolant injection system (HPCI) did not worked properly, but the steam in the reactor pressure vessel (RPV) leaked through the turbine of HPCI to the suppression chamber since 12/3/2011 12:35. It is assumed that the Tsunami flooded the torus room where the suppression chamber was placed. Proposed accident scenario agrees with the data of the plant parameters obtained just after the accident. It is estimated that the water injection by HPIC was stopped since around at 13/3 19:00 and the water level in RPV decreased since then. It is estimated that the RPV broke at 14/3 8:55 and water could injected from fire engines due to the depression due to the rupture of RPV. There was little water left in RPV at the time of the rupture. If the present scenario is correct, the behavior that operators in the plant stopped HPCI at 13/3 2:42 did not affect seriously on the RPV rupture. If HPCI was working properly until the operators stopped it, the plant parameters obtained in the accident cannot be explained. (author)

  6. Heat Roadmap Europe 3 (STRATEGO)

    Connolly, David; Hansen, Kenneth; Drysdale, David

    Heat Roadmap Europe 3 is from work package 2 of the STRATEGO project (http://stratego-project.eu/). It quantifies the impact of implementing various energy efficiency measures in the heating and cooling sectors of five EU Member States: Czech Republic, Croatia, Italy, Romania, and the United...... of approximately €1.1 trillion in energy efficiency measures across all five of these countries, between 2010 and 2050, will save enough fuel to reduce the costs of their energy systems. After considering both the initial investment and the resulting savings, the total annual cost of the heating, cooling......, and electricity sectors is reduced by an average of ~15% in each country. These initial investments are primarily required in heat savings for the buildings, district heating in urban areas, and electric heat pumps in rural areas. In essence, energy efficiency measures in the heating sector will enable EU Member...

  7. How to recover more value from small pine trees: Essential oils and resins

    Kelkar, Vasant M.; Geils, Brian W.; Becker, Dennis R.; Overby, Steven T.; Neary, Daniel G.

    2006-01-01

    In recent years, the young dense forests of northern Arizona have suffered extreme droughts, wildfires, and insect outbreaks. Improving forest health requires reducing forest density by cutting many small-diameter trees with the consequent production of large volumes of residual biomass. To offset the cost of handling this low-value timber, additional marketing options for current operations are urgently needed to recover more value as wood products, energy, and chemicals. Northern Arizona forests are predominantly composed of ponderosa pine (Pinus ponderosa) which, besides producing abundant timber, can also yield many useful chemicals such as essential oils and resins. We describe a case study to assess the opportunities, constraints, and information required to integrate recovery of essential oils into forest and mill operations as might be used in northern Arizona. Preliminary results support the proposition there is an available, large supply of biomass with high concentrations of essential oils. The chemistry and process engineering for recovering these essential oils by distillation are well known. The potential output and uses also appear attractive given the substantial United States market for such products. However, less is known of the capability of essential oils extracted from ponderosa pine to compete with products imported from other countries. A more detailed assessment of product uses and further analysis of viable markets and environmental benefits are justified. (author)

  8. Phytoremediation of 1,4-dioxane-containing recovered groundwater.

    Ferro, Ari M; Kennedy, Jean; LaRue, James C

    2013-01-01

    The results of a pilot-scale phytoremediation study are reported in this paper. Small plots of trees established on a closed municipal waste landfill site were irrigated with recovered groundwater containing 1,4-dioxane (dioxane) and other volatile organic compounds (VOCs). The plots were managed to minimize the leaching of irrigation water, and leaching was quantified by the use of bromide tracer. Results indicated that the dioxane (2.5 microg/L) was effectively removed, probably via phytovolatilization, and that a full-scale phytoremediation system could be used. A system is now in place at the site in which the recovered groundwater can be treated using two different approaches. A physical treatment system (PTS) will be used during the winter months, and a 12 ha phytoremediation system (stands of coniferous trees) will be used during the growing season. The PTS removes VOCs using an air-stripper, and destroys dioxane using a photo-catalytic oxidation process. Treated water will be routed to the local sewer system. The phytoremediation system, located on the landfill, will be irrigated with effluent from the PTS air-stripper containing dioxane. Seasonal use of the phytoremediation system will reduce reliance on the photo-catalytic oxidation process that is extremely energy consumptive and expensive to operate.

  9. Recovering Nimbus era Observations at the NASA GES DISC

    Meyer, D. J.; Johnson, J. E.; Esfandiari, A. E.; Zamkoff, E. B.; Al-Jazrawi, A. F.; Gerasimov, I. V.; Alcott, G. T.

    2017-12-01

    Between 1964 and 1978, NASA launched a series of seven Nimbus meteorological satellites which provided Earth observations for 30 years. These satellites, carrying a total of 33 instruments to observe the Earth at visible, infrared, ultraviolet, and microwave wavelengths, revolutionized weather forecasting, provided early observations of ocean color and atmospheric ozone, and prototyped location-based search and rescue capabilities. The Nimbus series paved the way for a number of currently operational systems such as the EOS Terra, Aqua and Aura platforms.The original data archive included both magnetic tapes and film media. These media are well past their expected end of life, placing at risk valuable data that are critical to extending the history of Earth observations back in time. GES DISC has been incorporating these data into a modern online archive by recovering the digital data files from the tapes, and scanning images of the data from film strips. The original data products were written on obsolete hardware systems in outdated file formats, and in the absence of metadata standards at that time, were often written in proprietary file structures. Through a tedious and laborious process, oft-corrupted data are recovered, and incomplete metadata and documentation are reconstructed.

  10. Recovering missing mesothelioma deaths in death certificates using hospital records.

    Santana, Vilma S; Algranti, Eduardo; Campos, Felipe; Cavalcante, Franciana; Salvi, Leonardo; Santos, Simone A; Inamine, Rosemeire N; Souza, William; Consonni, Dario

    2018-04-02

    In Brazil, underreporting of mesothelioma and cancer of the pleura (MCP) is suspected to be high. Records from death certificates (SIM) and hospital registers (SIH-SUS) can be combined to recover missing data but only anonymous databases are available. This study shows how common data can be used for linkage and as an assessment of accuracy. Mesothelioma (all sites, ICD-10 codes C45.0-C45.9) and cancer of the pleura (C38.4) were retrieved from both information systems and combined using a linkage algorithm. Accuracy was examined with non-anonymous databases, limited to the state of São Paulo. We found 775 cases in death certificates and 283 in hospital registers. The linkage matched 57 cases, all accurately paired. Three cases, 0.4% in SIM and 1.3% in SIH-SUS, could not be matched because of data inconsistencies. A computer linkage can recover MCP cases from hospital records not found in death certificates in Brazil. © 2018 Wiley Periodicals, Inc.

  11. CFD as a Design Tool for a Concentric Heat Exchanger

    Oosterhuis, Joris; Bühler, Simon; wilcox, D; van der Meer, Theodorus H.

    2012-01-01

    A concentric gas-to-gas heat exchanger is designed for application as a recuperator in the domestic boiler industry. The recuperator recovers heat from the exhaust gases of a combustion process to preheat the ingoing gaseous fuel mixture resulting in increased fuel efficiency. This applied study

  12. Comparison of silorane and methacrylate-based composites on the polymerization heat generated with different light-curing units and dentin thicknesses.

    Guiraldo, Ricardo Danil; Consani, Simonides; Consani, Rafael Leonardo Xediek; Berger, Sandrine Bittencourt; Correr, Américo Bortolazzo; Sinhoreti, Mário Alexandre Coelho; Correr-Sobrinho, Lourenço

    2013-01-01

    This study evaluated the temperature variation in the pulp chamber during photoactivation of two restorative composite resins (Filtek P90 silorane-based composite and Heliomolar methacrylate-based composite) with either a quartz-tungsten-halogen (QTH) or light-emitting diodes (LED) light-curing unit (LCU) and using dentin thicknesses (0.5 and 1.0 mm). Standardized cavities (2x2x2 mm) were prepared in 80 bovine incisors, which were randomly assigned to 8 groups according to the photoactivation method and dentin thickness. Filtek P90 and Heliomolar (both in shade A3) were used with their respective adhesive systems (P90 self-etch primer / P90 adhesive bond and Excite adhesive). All experiments were carried out in a controlled environment (37°C). The temperature variations (°C) were recorded using a digital thermometer attached to a K-type thermocouple. The results were analyzed statistically by ANOVA and Tukey's test (α=0.05). For composite/dentin thickness interaction, temperature increase was significantly higher in 0.5 mm dentin thickness (40.07°C) compared with 1.0 mm dentin thickness (39.61°C) for Filtek P90. For composite/LCU interaction, the temperature increase was significantly higher for Filtek P90 (39.21°C - QTH and 40.47°C - LED) compared with Heliomolar (38.40°C - QTH and 39.30°C - LED). The silorane-based composite promoted higher temperature increase in the pulp chamber than the methacrylate-based composite.

  13. Performance and availability of seawater distiller with heat pipe utilizing low grade waste heat

    Park, Chang Dae; Chung, Kyung Yul [Korea Institute of Machinery and Materials, Daejeon (Korea, Republic of); Tanaka, Hiroshi [Department of Mechanical Engineering, Ulsan (Korea, Republic of)

    2013-01-15

    Exhaust gas from a small portable electric generator is simply exhausted to the surroundings because the capacity and quality of the waste heat of this gas is generally not sufficient to recover and utilize. We have proposed a seawater distiller utilizing the thermal energy of waste gas from an electric generator. The distiller recovers heat from the waste gas by means of a heat pipe and uses it effectively through a multiple effect diffusion type structure. We constructed an experimental apparatus with a vertical single effect still having a 4 stroke 50cc generator engine and found that the experimental results for distillate productivity show good agreement with the theoretical predictions. The results show that the distiller can recover 52W of waste heat from the gas at 171.deg.C, and {approx}85%, of the recovered heat can be utilized for distillation to produce 70g/h of fresh water. This is equivalent to a productivity of 500g/h in the case of a 10 effect still. Therefore, the proposed distiller should be useful in remote areas where electricity and water grids are inadequate.

  14. Combined heat and power economic dispatch by a fish school search algorithm

    Santos, Leonardo Trigueiro dos; Costa e Silva, Marsil de Athayde [Undergraduate in Mechatronics Engineering, Pontifical Catholic University of Parana, Curitiba, PR (Brazil); Coelho, Leandro dos Santos [Industrial and Systems Engineering Graduate Program, PPGEPS, Pontifical Catholic University of Parana, Curitiba, PR (Brazil)], e-mail: leandro.coelho@pucpr.br

    2010-07-01

    The conversion of primary fossil fuels, such as coal and gas, to electricity is a a relatively inefficient process. Even the most modern combined cycle plants can only achieve efficiencies of between 50-60%. A great portion of the energy wasted in this conversion process is released to the environment as waste heat. The principle of combined heat and power, also known as cogeneration, is to recover and make beneficial use of this heat, significantly raising the overall efficiency of the conversion process. However, the optimal utilization of multiple combined heat and power systems is a complicated problem which needs powerful methods to solve. This paper presents a fish school search (FSS) algorithm to solve the combined heat and power economic dispatch problem. FSS is a novel approach recently proposed to perform search in complex optimization problems. Some simulations presented in the literature indicated that FSS can outperform many bio-inspired algorithms, mainly in multimodal functions. The search process in FSS is carried out by a population of limited-memory individuals - the fishes. Each fish represents a possible solution to the problem. Similarly to particle swarm optimization or genetic algorithm, search guidance in FSS is driven by the success of some individual members of the population. A four-unit system proposed recently which is a benchmark case in the power systems field has been validated as a case study in this paper. (author)

  15. A Thermoelectric Waste-Heat-Recovery System for Portland Cement Rotary Kilns

    Luo, Qi; Li, Peng; Cai, Lanlan; Zhou, Pingwang; Tang, Di; Zhai, Pengcheng; Zhang, Qingjie

    2015-06-01

    Portland cement is produced by one of the most energy-intensive industrial processes. Energy consumption in the manufacture of Portland cement is approximately 110-120 kWh ton-1. The cement rotary kiln is the crucial equipment used for cement production. Approximately 10-15% of the energy consumed in production of the cement clinker is directly dissipated into the atmosphere through the external surface of the rotary kiln. Innovative technology for energy conservation is urgently needed by the cement industry. In this paper we propose a novel thermoelectric waste-heat-recovery system to reduce heat losses from cement rotary kilns. This system is configured as an array of thermoelectric generation units arranged longitudinally on a secondary shell coaxial with the rotary kiln. A mathematical model was developed for estimation of the performance of waste heat recovery. Discussions mainly focus on electricity generation and energy saving, taking a Φ4.8 × 72 m cement rotary kiln as an example. Results show that the Bi2Te3-PbTe hybrid thermoelectric waste-heat-recovery system can generate approximately 211 kW electrical power while saving 3283 kW energy. Compared with the kiln without the thermoelectric recovery system, the kiln with the system can recover more than 32.85% of the energy that used to be lost as waste heat through the kiln surface.

  16. Modeling the dynamic operation of a small fin plate heat exchanger – parametric analysis

    Motyliński Konrad

    2015-09-01

    Full Text Available Given its high efficiency, low emissions and multiple fuelling options, the solid oxide fuel cells (SOFC offer a promising alternative for stationary power generators, especially while engaged in micro-combined heat and power (μ-CHP units. Despite the fact that the fuel cells are a key component in such power systems, other auxiliaries of the system can play a critical role and therefore require a significant attention. Since SOFC uses a ceramic material as an electrolyte, the high operating temperature (typically of the order of 700–900 °C is required to achieve sufficient performance. For that reason both the fuel and the oxidant have to be preheated before entering the SOFC stack. Hot gases exiting the fuel cell stack transport substantial amount of energy which has to be partly recovered for preheating streams entering the stack and for heating purposes. Effective thermal integration of the μ-CHP can be achieved only when proper technical measures are used. The ability of efficiently preheating the streams of oxidant and fuel relies on heat exchangers which are present in all possible configurations of power system with solid oxide fuel cells. In this work a compact, fin plate heat exchanger operating in the high temperature regime was under consideration. Dynamic model was proposed for investigation of its performance under the transitional states of the fuel cell system. Heat exchanger was simulated using commercial modeling software. The model includes key geometrical and functional parameters. The working conditions of the power unit with SOFC vary due to the several factors, such as load changes, heating and cooling procedures of the stack and others. These issues affect parameters of the incoming streams to the heat exchanger. The mathematical model of the heat exchanger is based on a set of equations which are simultaneously solved in the iterative process. It enables to define conditions in the outlets of both the hot and the

  17. Amphotericin B and caspofungin resistance in Candida glabrata isolates recovered from a critically ill patient

    Krogh-Madsen, Mikkel; Arendrup, Maiken Cavling; Heslet, Lars

    2006-01-01

    BACKGROUND: Consecutive Candida glabrata isolates recovered from a patient in an intensive care unit were resistant to amphotericin B (minimum inhibitory concentration, up to 32 mu g/mL; determined by Etest [AB Biodisk]). Analyses at the national reference laboratory showed that some isolates were...... also resistant to azoles and caspofungin. In this study, 4 isolates were studied thoroughly using susceptibility assays and a mouse model and to determine clonality. METHODS: Different broth microdilution tests, Etests, and time-kill studies for antifungals were performed in different media. Three...... isolates obtained from nonrelated patients, and a reference strain. RESULTS: The murine model indicated that 1 isolate was resistant to amphotericin B, 1 had intermediate susceptibility, and 1 was fully susceptible. Two of the 3 isolates were resistant to caspofungin. Microdilution methods did not reliably...

  18. Proposal for a district heat supply system

    Alefeld, G.

    1976-01-01

    A district heating scheme is proposed which makes it possible to use the waste heat from power stations for the supply of households and industry. The heat is stored by evaporation of ammonia salts or liquids with dissolved salts. Both substances are transported on existing rail- or waterways to heating stations near the consumers, and the heat recovered by reaction of the two components. Then the product of reaction is transported back to the power stations, and reactivated by heat again. Based on a cost estimation, it can be shown that the proposed heat transport with heat trains or ships, at distances up to 100 km, results in heat costs which are to-day already below that of heat from fuel oil. The investment required for the heat transport system is unusually low due to the use of transport ways which already exist. The district heating system is not only favourable in respect of the environment, but actually reduces its present strain, both at the consumer and at the power stations. The technical advantages of the suggested concept, especially the possibility of introducing it in stages, are discussed. The consequences for the national economy regarding the safety of supply and the trade balance, as well as for the public transport undertakings, are obvious, and therefore not included in the paper. (orig.) [de

  19. Recovery of low temperature heat in oil mills

    Carré Patrick

    2012-11-01

    Full Text Available Energy consumption in oil mills is a major item of costs and a sensitive point in the production of biofuels. To improve their performance, industrials can recover lowtemperature heat thanks to a new technology of heat exchangers suitable for treating granular solid materials. Information about the energy requirements of the rapeseed crushing being not readily available, the article gives a detailed assessment of consumption items (per ton of seed: 263 MJ for preparation operations and 284 MJ for solvent extraction. These exchangers used as pre-conditioners saves about 55 MJ.t−1 of heat by use of steam condensates. We could go further in use of these devices on the one hand to recover heat from press cake and meal, and secondly to use recovered energy to dry and warm up the seeds before pre-pressing. In this configuration, the energy savings could reach 38% of current needs.

  20. Geothermal heat pump performance

    Boyd, Tonya L.; Lienau, Paul J.

    1995-01-01

    Geothermal heat pump systems are a promising new energy technology that has shown rapid increase in usage over the past ten years in the United States. These systems offer substantial benefits to customers and utilities in energy (kWh) and demand (kW) savings. The purpose of this study was to determine what existing monitored data was available mainly from electric utilities on heat pump performance, energy savings and demand reduction for residential, school, and commercial building applications. Information was developed on the status of electric utility marketing programs, barriers to market penetration, incentive programs, and benefits.