WorldWideScience

Sample records for heat load synchrotron

  1. Beam heat load investigations with a cold vacuum chamber for diagnostics in a synchrotron light source

    Energy Technology Data Exchange (ETDEWEB)

    Voutta, Robert

    2016-04-22

    The beam heat load is a crucial input parameter for the cryogenic design of superconducting insertion devices. To understand the discrepancies between the predicted heat load of an electron beam to a cold bore and the heat load observed in superconducting devices, a cold vacuum chamber for diagnostics has been built. Extensive beam heat load measurements were performed at the Diamond light source. They are analysed systematically and combined with complementary impedance bench measurements.

  2. Beam heat load investigations with a cold vacuum chamber for diagnostics in a synchrotron light source

    OpenAIRE

    Voutta, Robert

    2016-01-01

    The beam heat load is a crucial input parameter for the cryogenic design of superconducting insertion devices. To understand the discrepancies between the predicted heat load of an electron beam to a cold bore and the heat load observed in superconducting devices, a cold vacuum chamber for diagnostics has been built. Extensive beam heat load measurements were performed at the Diamond light source. They are analysed systematically and combined with complementary impedance bench measurements.

  3. Potential Remedies for the High Synchrotron-Radiation-Induced Heat Load for Future Highest-Energy-Proton Circular Colliders

    Science.gov (United States)

    Cimino, R.; Baglin, V.; Schäfers, F.

    2015-12-01

    We propose a new method for handling the high synchrotron radiation (SR) induced heat load of future circular hadron colliders (like FCC-hh). FCC-hh are dominated by the production of SR, which causes a significant heat load on the accelerator walls. Removal of such a heat load in the cold part of the machine, as done in the Large Hadron Collider, will require more than 100 MW of electrical power and a major cooling system. We studied a totally different approach, identifying an accelerator beam screen whose illuminated surface is able to forward reflect most of the photons impinging onto it. Such a reflecting beam screen will transport a significant part of this heat load outside the cold dipoles. Then, in room temperature sections, it could be more efficiently dissipated. Here we will analyze the proposed solution and address its full compatibility with all other aspects an accelerator beam screen must fulfill to keep under control beam instabilities as caused by electron cloud formation, impedance, dynamic vacuum issues, etc. If experimentally fully validated, a highly reflecting beam screen surface will provide a viable and solid solution to be eligible as a baseline design in FCC-hh projects to come, rendering them more cost effective and sustainable.

  4. Potential Remedies for the High Synchrotron-Radiation-Induced Heat Load for Future Highest-Energy-Proton Circular Colliders

    CERN Document Server

    AUTHOR|(CDS)2084568; Baglin, Vincent; Schaefers, Franz

    2015-01-01

    We propose a new method for handling the high synchrotron radiation (SR) induced heat load of future circular hadron colliders (like FCC-hh). FCC-hh are dominated by the production of SR, which causes a significant heat load on the accelerator walls. Removal of such a heat load in the cold part of the machine, as done in the Large Hadron Collider, will require more than 100 MW of electrical power and a major cooling system. We studied a totally different approach, identifying an accelerator beam screen whose illuminated surface is able to forward reflect most of the photons impinging onto it. Such a reflecting beam screen will transport a significant part of this heat load outside the cold dipoles. Then, in room temperature sections, it could be more efficiently dissipated. Here we will analyze the proposed solution and address its full compatibility with all other aspects an accelerator beam screen must fulfill to keep under control beam instabilities as caused by electron cloud formation, impedance, dynamic...

  5. Potential Remedies for the High Synchrotron-Radiation-Induced Heat Load for Future Highest-Energy-Proton Circular Colliders.

    Science.gov (United States)

    Cimino, R; Baglin, V; Schäfers, F

    2015-12-31

    We propose a new method for handling the high synchrotron radiation (SR) induced heat load of future circular hadron colliders (like FCC-hh). FCC-hh are dominated by the production of SR, which causes a significant heat load on the accelerator walls. Removal of such a heat load in the cold part of the machine, as done in the Large Hadron Collider, will require more than 100 MW of electrical power and a major cooling system. We studied a totally different approach, identifying an accelerator beam screen whose illuminated surface is able to forward reflect most of the photons impinging onto it. Such a reflecting beam screen will transport a significant part of this heat load outside the cold dipoles. Then, in room temperature sections, it could be more efficiently dissipated. Here we will analyze the proposed solution and address its full compatibility with all other aspects an accelerator beam screen must fulfill to keep under control beam instabilities as caused by electron cloud formation, impedance, dynamic vacuum issues, etc. If experimentally fully validated, a highly reflecting beam screen surface will provide a viable and solid solution to be eligible as a baseline design in FCC-hh projects to come, rendering them more cost effective and sustainable.

  6. In situ surface monitoring system for synchrotron mirrors under high heat load.

    Science.gov (United States)

    Mui, P H; Srajer, G; Mills, D M

    1997-08-01

    A portable electro-optical system capable of real-time measurements of surface slope distortions down to 0.5 murad is described; the system is limited primarily by its short-term stability. The system employs an angle measurement technique that, in combination with the least-squares signal extraction method, reduces system fluctuations. In addition, a multireflection technique is used to enhance the detectable resolution. Although designed for use with mirrors for synchrotron radiation sources, this system has the flexibility to be applied to other optical components. The prototype system has been tested on a sample mirror piece, and preliminary results are presented. A brief discussion about the extension of this metrology unit to adaptive optics is also given.

  7. Synchrotron radiation absorber for high density loads

    Science.gov (United States)

    Anashin, V. V.; Kuzminych, V. S.; Trakhtenberg, E. M.; Zholents, A. A.

    1991-10-01

    A design of a special synchrotron radiation absorber for the storage ring VEPP-4M is presented. The density of the synchrotron radiation power on the absorber surface is up to 500 W/mm 2. The absorber is made from a beryllium plate, brazed inside to the copper vacuum chamber, which is intensively water-cooled from outside.

  8. Synchrotron-based FTIR spectromicroscopy: Cytotoxicity and heating considerations

    Energy Technology Data Exchange (ETDEWEB)

    Holman, Hoi-Ying N.; Martin, Michael C.; McKinney, Wayne R.

    2002-12-13

    Synchrotron radiation-based Fourier transform infrared (SR-FTIR) spectromicroscopy is a newly emerging bioanalytical and imaging tool. This unique technique provides mid-infrared (IR) spectra, hence chemical information, with high signal-to-noise at spatial resolutions as fine as 3 to 10 microns. Thus it enables researchers to locate, identify, and track specific chemical events within an individual living mammalian cell. Mid-IR photons are too low in energy (0.05 - 0.5 eV) to either break bonds or to cause ionization. In this review, we show that the synchrotron IR beam has no detectable effects on the short- and long-term viability, reproductive integrity, cell-cycle progression, and mitochondrial metabolism in living human cells, and produces only minimal sample heating (< 0.5 degrees C). These studies have established an important foundation for SR-FTIR spectromicroscopy in biological and biomedical research.

  9. Synchrotron-based FTIR spectromicroscopy Cytotoxicity and heating considerations

    CERN Document Server

    Holman, H Y N; McKinney, W R

    2002-01-01

    Synchrotron radiation-based Fourier transform infrared (SR-FTIR) spectromicroscopy is a newly emerging bioanalytical and imaging tool. This unique technique provides mid-infrared (IR) spectra, hence chemical information, with high signal-to-noise at spatial resolutions as fine as 3 to 10 microns. Thus it enables researchers to locate, identify, and track specific chemical events within an individual living mammalian cell. Mid-IR photons are too low in energy (0.05 - 0.5 eV) to either break bonds or to cause ionization. In this review, we show that the synchrotron IR beam has no detectable effects on the short- and long-term viability, reproductive integrity, cell-cycle progression, and mitochondrial metabolism in living human cells, and produces only minimal sample heating (< 0.5 degrees C). These studies have established an important foundation for SR-FTIR spectromicroscopy in biological and biomedical research.

  10. SYNCHROTRON HEATING BY A FAST RADIO BURST IN A SELF-ABSORBED SYNCHROTRON NEBULA AND ITS OBSERVATIONAL SIGNATURE

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Yuan-Pei; Dai, Zi-Gao [School of Astronomy and Space Science, Nanjing University, Nanjing 210093 (China); Zhang, Bing, E-mail: zhang@physics.unlv.edu [Department of Physics and Astronomy, University of Nevada, Las Vegas, NV 89154 (United States)

    2016-03-01

    Fast radio bursts (FRBs) are mysterious transient sources. If extragalactic, as suggested by their relative large dispersion measures, their brightness temperatures must be extremely high. Some FRB models (e.g., young pulsar model, magnetar giant flare model, or supra-massive neutron star collapse model) suggest that they may be associated with a synchrotron nebula. Here we study a synchrotron-heating process by an FRB in a self-absorbed synchrotron nebula. If the FRB frequency is below the synchrotron self-absorption frequency of the nebula, electrons in the nebula would absorb FRB photons, leading to a harder electron spectrum and enhanced self-absorbed synchrotron emission. In the meantime, the FRB flux is absorbed by the nebula electrons. We calculate the spectra of FRB-heated synchrotron nebulae, and show that the nebula spectra would show a significant hump in several decades near the self-absorption frequency. Identifying such a spectral feature would reveal an embedded FRB in a synchrotron nebula.

  11. Laser-heating-based active optics for synchrotron radiation applications

    CERN Document Server

    Yang, Fugui; Zhang, Xiaowei

    2016-01-01

    Active optics has attracted considerable interest from researchers in synchrotron radiation facilities, because of its capacity for x-ray wavefront correction. Here, we report a novel and efficient technique for correcting or modulating a mirror surface profile based on laser-heating-induced thermal expansion. An experimental study of the characteristics of the surface thermal deformation response indicates that the power of a milliwatt laser yields a bump height as low as sub-nanometer scale, and that variation of the spot size modulates the response function width effectively. In addition, the capacity of the laser-heating technique for free-form surface modulation is demonstrated via a surface correction experiment. The developed method is a promising new approach towards effective x-ray active optics coupled with at-wavelength metrology techniques.

  12. Heat transfer studies for a crystal in a synchrotron radiation beamline

    Indian Academy of Sciences (India)

    A K Sinha

    2009-04-01

    Heat load studies have been performed for the first crystal of a double crystal monochromator to be installed in a beamline of the 2·5 GeV synchrotron radiation source Indus-2. Finite element analysis (FEA) has been used to calculate the temperature distribution and the mechanical distortions on these crystals. Several cases of cooling schemes and heat loads have been studied. Based on these FEA results, the analytical relationships available in the literature have been modified. It is shown that modified analytical results compare well with the empirical results obtained from FEA. The optimisation of the cooling conditions can be achieved by doing FEA calculations for only one case. All other cases can then be calculated by using analytical relations proposed here. The proposed analytical equations are generic in nature and can be applied for any source—crystal combination and therefore would be useful for performance prediction of any new monochromator on a new synchrotron source without taking recourse to time consuming, computation-intensive FEA.

  13. Workshop on high heat load x-ray optics

    Energy Technology Data Exchange (ETDEWEB)

    1990-01-01

    A workshop on High Heat Load X-Ray Optics'' was held at Argonne National Laboratory on August 3--5, 1989. The object of this workshop was to discuss recent advances in the art of cooling x-ray optics subject to high heat loads from synchrotron beams. The cooling of the first optical element in the intense photon beams that will be produced in the next generation of synchrotron sources is recognized as one of the major challenges that must be faced before one will be able to use these very intense beams in future synchrotron experiments. Considerable advances have been made in this art during the last few years, but much work remains to be done before the heating problem can be said to be completely solved. Special emphasis was placed on recent cooling experiments and detailed finite element'' and finite difference'' calculations comparing experiment with theory and extending theory to optimize performance.

  14. APS high heat load monochromator

    Energy Technology Data Exchange (ETDEWEB)

    Lee, W.K.; Mills, D.

    1993-02-01

    This document contains the design specifications of the APS high heat load (HHL) monochromator and associated accessories as of February 1993. It should be noted that work is continuing on many parts of the monochromator including the mechanical design, crystal cooling designs, etc. Where appropriate, we have tried to add supporting documentation, references to published papers, and calculations from which we based our decisions. The underlying philosophy behind performance specifications of this monochromator was to fabricate a device that would be useful to as many APS users as possible, that is, the design should be as generic as possible. In other words, we believe that this design will be capable of operating on both bending magnet and ID beamlines (with the appropriate changes to the cooling and crystals) with both flat and inclined crystal geometries and with a variety of coolants. It was strongly felt that this monochromator should have good energy scanning capabilities over the classical energy range of about 4 to 20 keywith Si (111) crystals. For this reason, a design incorporating one rotation stage to drive both the first and second crystals was considered most promising. Separate rotary stages for the first and second crystals can sometimes provide more flexibility in their capacities to carry heavy loads (for heavily cooled first crystals or sagittal benders of second crystals), but their tuning capabilities were considered inferior to the single axis approach.

  15. Beam heat load and pressure rise in a cold vacuum chamber

    Directory of Open Access Journals (Sweden)

    S. Casalbuoni

    2007-09-01

    Full Text Available The beam heat load and the pressure in the vacuum chamber of the cold bore superconducting undulator installed at ANKA (ANgstrom source KArlsruhe have been monitored for almost two years. Possible sources of the observed heat load could be synchrotron radiation from upstream magnets, image currents, electron and ion bombardment. In this paper, the various possible contributions to the heat load are discussed and compared with experimental results. The dynamic pressure increases nonlinearly with the average beam current. The current where it assumes a maximum varies both with the bunch intensity and with the initial vacuum pressure. A correlation between the heat load and the dynamic pressure has been observed. This study suggests that electron bombardment could explain the beam heat load and pressure rise observed for a bunch length of 10 mm.

  16. Heat Load Estimator for Smoothing Pulsed Heat Loads on Supercritical Helium Loops

    Science.gov (United States)

    Hoa, C.; Lagier, B.; Rousset, B.; Bonnay, P.; Michel, F.

    Superconducting magnets for fusion are subjected to large variations of heat loads due to cycling operation of tokamaks. The cryogenic system shall operate smoothly to extract the pulsed heat loads by circulating supercritical helium into the coils and structures. However the value of the total heat loads and its temporal variation are not known before the plasma scenario starts. A real-time heat load estimator is of interest for the process control of the cryogenic system in order to anticipate the arrival of pulsed heat loads to the refrigerator and finally to optimize the operation of the cryogenic system. The large variation of the thermal loads affects the physical parameters of the supercritical helium loop (pressure, temperature, mass flow) so those signals can be used for calculating instantaneously the loads deposited into the loop. The methodology and algorithm are addressed in the article for estimating the heat load deposition before it reaches the refrigerator. The CEA patented process control has been implemented in a Programmable Logic Controller (PLC) and has been successfully validated on the HELIOS test facility at CEA Grenoble. This heat load estimator is complementary to pulsed load smoothing strategies providing an estimation of the optimized refrigeration power. It can also effectively improve the process control during the transient between different operating modes by adjusting the refrigeration power to the need. This way, the heat load estimator participates to the safe operation of the cryogenic system.

  17. Load Management in District Heating Operation

    DEFF Research Database (Denmark)

    Li, Hongwei; Wang, Stephen Jia

    2015-01-01

    heating load can be reduced through building demand side management. The building thermal mass can be used to shift the heating supply under the circumstance without jeopardizing the consumer thermal comfort. In this paper, the multi-agent framework is applied to a simplified building dynamic model...

  18. Residential Variable-Capacity Heat Pumps Sized to Heating Loads

    Energy Technology Data Exchange (ETDEWEB)

    Munk, Jeffrey D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Jackson, Roderick K. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Odukomaiya, Adewale [Georgia Inst. of Technology, Atlanta, GA (United States); Gehl, Anthony C. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2014-01-01

    Variable capacity heat pumps are an emerging technology offering significant energy savings potential and improved efficiency. With conventional single-speed systems, it is important to appropriately size heat pumps for the cooling load as over-sizing would result in cycling and insufficient latent capacity required for humidity control. These appropriately sized systems are often under-sized for the heating load and require inefficient supplemental electric resistance heat to meet the heating demand. Variable capacity heat pumps address these shortcomings by providing an opportunity to intentionally size systems for the dominant heating season load without adverse effects of cycling or insufficient dehumidification in the cooling season. This intentionally-sized system could result in significant energy savings in the heating season, as the need for inefficient supplemental electric resistance heat is drastically reduced. This is a continuation of a study evaluating the energy consumption of variable capacity heat pumps installed in two unoccupied research homes in Farragut, a suburb of Knoxville, Tennessee. In this particular study, space conditioning systems are intentionally sized for the heating season loads to provide an opportunity to understand and evaluate the impact this would have on electric resistance heat use and dehumidification. The results and conclusions drawn through this research are valid and specific for portions of the Southeastern and Midwestern United States falling in the mixed-humid climate zone. While other regions in the U.S. do not experience this type of climate, this work provides a basis for, and can help understand the implications of other climate zones on residential space conditioning energy consumption. The data presented here will provide a framework for fine tuning residential building EnergyPlus models that are being developed.

  19. Residential Variable-Capacity Heat Pumps Sized to Heating Loads

    Energy Technology Data Exchange (ETDEWEB)

    Munk, Jeffrey D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Jackson, Roderick K. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Odukomaiya, Adewale [Georgia Inst. of Technology, Atlanta, GA (United States); Gehl, Anthony C. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2014-01-01

    Variable capacity heat pumps are an emerging technology offering significant energy savings potential and improved efficiency. With conventional single-speed systems, it is important to appropriately size heat pumps for the cooling load as over-sizing would result in cycling and insufficient latent capacity required for humidity control. These appropriately sized systems are often under-sized for the heating load and require inefficient supplemental electric resistance heat to meet the heating demand. Variable capacity heat pumps address these shortcomings by providing an opportunity to intentionally size systems for the dominant heating season load without adverse effects of cycling or insufficient dehumidification in the cooling season. This intentionally-sized system could result in significant energy savings in the heating season, as the need for inefficient supplemental electric resistance heat is drastically reduced. This is a continuation of a study evaluating the energy consumption of variable capacity heat pumps installed in two unoccupied research homes in Farragut, a suburb of Knoxville, Tennessee. In this particular study, space conditioning systems are intentionally sized for the heating season loads to provide an opportunity to understand and evaluate the impact this would have on electric resistance heat use and dehumidification. The results and conclusions drawn through this research are valid and specific for portions of the Southeastern and Midwestern United States falling in the mixed-humid climate zone. While other regions in the U.S. do not experience this type of climate, this work provides a basis for, and can help understand the implications of other climate zones on residential space conditioning energy consumption. The data presented here will provide a framework for fine tuning residential building EnergyPlus models that are being developed.

  20. High-Intensity Synchrotron Radiation Effects

    CERN Document Server

    Suetsugu, Y

    2016-01-01

    Various effects of intense synchrotron radiation on the performance of particle accelerators, especially for storage rings, are discussed. Following a brief introduction to synchrotron radiation, the basic concepts of heat load, gas load, electron emission, and the countermeasures against these effects are discussed.

  1. Indirect solar loading of waste heat radiators

    Energy Technology Data Exchange (ETDEWEB)

    Kirkpatrick, R.C.; Tabor, J.E.; Lindman, E.L.; Cooper, A.J.

    1988-01-01

    Waste heat from space based power systems must ultimately be radiated away into space. The local topology around the radiators must be considered from two stand-points: the scattering of sunlight onto the surfaces of the radiator and the heat load that the radiator may put on near-by components of the system. A view factor code (SNAP) developed at Los Alamos allows the computation of the steady-state radiation environment for complex 3-D geometries. An example of the code's utility is given. 4 refs., 2 figs., 1 tab.

  2. Analyzing Design Heating Loads in Superinsulated Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Arena, Lois [Consortium for Advanced Residential Buildings, Norwalk, CT (United States)

    2015-06-16

    The U.S. Department of Energy’s Building America research team Consortium for Advanced Residential Buildings (CARB) worked with the EcoVillage cohousing community in Ithaca, New York, on the Third Residential EcoVillage Experience neighborhood. This communityscale project consists of 40 housing units—15 apartments and 25 single-family residences. Units range in size from 450 ft2 to 1,664 ft2 and cost from $80,000 for a studio apartment to $235,000 for a three- or four-bedroom single-family home. For the research component of this project, CARB analyzed current heating system sizing methods for superinsulated homes in cold climates to determine if changes in building load calculation methodology should be recommended. Actual heating energy use was monitored and compared to results from the Air Conditioning Contractors of America’s Manual J8 (MJ8) and the Passive House Planning Package software. Results from that research indicate that MJ8 significantly oversizes heating systems for superinsulated homes and that thermal inertia and internal gains should be considered for more accurate load calculations.

  3. Beam heat load due to geometrical and resistive wall impedance in COLDDIAG

    Science.gov (United States)

    Casalbuoni, S.; Migliorati, M.; Mostacci, A.; Palumbo, L.; Spataro, B.

    2012-11-01

    One of the still open issues for the development of superconductive insertion devices is the understanding of the heat intake from the electron beam. With the aim of measuring the beam heat load to a cold bore and the hope to gain a deeper understanding in the underlying mechanisms, a cold vacuum chamber for diagnostics (COLDDIAG) was built. It is equipped with the following instrumentation: retarding field analyzers to measure the electron flux, temperature sensors to measure the beam heat load, pressure gauges, and mass spectrometers to measure the gas content. Possible beam heat load sources are: synchrotron radiation, wakefield effects due to geometrical and resistive wall impedance and electron/ion bombardment. The flexibility of the engineering design will allow the installation of the cryostat in different synchrotron light sources. COLDDIAG was first installed in the Diamond Light Source (DLS) in 2011. Due to a mechanical failure of the thermal transition of the cold liner, the cryostat had to be removed after one week of operation. After having implemented design changes in the thermal liner transition, COLDDIAG has been reinstalled in the DLS at the end of August 2012. In order to understand the beam heat load mechanism it is important to compare the measured COLDDIAG parameters with theoretical expectations. In this paper we report on the analytical and numerical computation of the COLDDIAG beam heat load due to coupling impedances deriving from unavoidable step transitions, ports used for pumping and diagnostics, surface roughness, and resistive wall. The results might have an important impact on future technological solutions to be applied to cold bore devices.

  4. Analyzing Design Heating Loads in Superinsulated Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Arena, Lois [Consortium for Advanced Residential Buildings, Norwalk, CT (United States)

    2015-06-01

    Super-insulated homes offer many benefits including improved comfort, reduced exterior noise penetration, lower energy bills, and the ability to withstand power and fuel outages under much more comfortable conditions than a typical home. While these homes aren't necessarily constructed with excessive mass in the form of concrete floors and walls, the amount of insulation and the increase in the thickness of the building envelope can lead to a mass effect, resulting in the structures ability to store much more heat than a code built home. This results in a very low thermal inertia making the building much less sensitive to drastic temperature swings thereby decreasing the peak heating load demand. During the winter of 2013/2014, CARB monitored the energy use of three homes in climate zone 6 in an attempt to evaluate the accuracy of two different mechanical system sizing methods for low load homes. Based on the results, it is recommended that internal and solar gains be included and some credit for thermal inertia be used in sizing calculations for super insulated homes.

  5. Static Heat Loads in the LHC Arc Cryostats: Final Assessment

    CERN Document Server

    Parma, V

    2010-01-01

    This note presents the final assessment of the static heat loads in the LHC arc cryostats, using different experimental methods during the first commissioning period in 2007. This assessment further develops and completes previous estimates made during the commissioning of sector 7_8 [1]. The estimate of the helium inventory, a prerequisite for the heat load calculation, is also presented. Heat loads to the cold mass are evaluated from the internal energy balance during natural as well as powered warm-ups of the helium baths in different subsector. The helium inventory is calculated from the internal energy balance during powered warm-ups and matched with previous assessments. Furthermore, heat loads to the thermal shield are estimated from the non-isothermal cooling of the supercritical helium in line E. The comparison of measured heat loads with previous estimates and with budgeted values is then presented, while their correlation with some important parameters like insulation vacuum pressure and some heat ...

  6. Heat loading limits for solid transuranic wastes storage

    Energy Technology Data Exchange (ETDEWEB)

    Spatz, T.L.

    1993-07-01

    Heat loading limits have been established for four storage configurations of TRU wastes. The calculations were performed assuming the worst case scenario whereby all the heat generated within a drum was generated within one ``cut`` and that this cut was located in the very center of the drum. Poly-boxes containing one HEPA filter were assumed to have a uniform heat generation throughout the filter. The maximum allowable temperatures were based on the materials in the containers. A comparison between the drum center temperature for a uniform heat load distribution and for the center temperature when the heat load is confined to one cut in the center of the drum is also illustrated. This comparison showed that the heat load of a particular drum can be more than doubled by distributing the sources of heat uniformly throughout the container.

  7. Short-term heat load forecasting for single family houses

    DEFF Research Database (Denmark)

    Bacher, Peder; Madsen, Henrik; Nielsen, Henrik Aalborg;

    2013-01-01

    This paper presents a method for forecasting the load for space heating in a single-family house. The forecasting model is built using data from sixteen houses located in Sønderborg, Denmark, combined with local climate measurements and weather forecasts. Every hour the hourly heat load for each ...

  8. The cryogenic cooling program in high-heat-load optics at the Advanced Photon Source

    Energy Technology Data Exchange (ETDEWEB)

    Rogers, C.S.

    1993-07-01

    This paper describes some of the aspects of the cryogenic optics program at the Advanced Photon Source (APS). A liquid-nitrogen-cooled, high-vacuum, double crystal monochromator is being fabricated at Argonne National Laboratory (ANL). A pumping system capable of delivering a variable flow rate of up to 10 gallons per minute of pressurized liquid nitrogen and removing 5 kilowatts of x-ray power is also being constructed. This specialized pumping system and monochromator will be used to test the viability of cryogenically cooled, high-heat-load synchrotron optics. It has been determined that heat transfer enhancement will be required for optics used with APS insertion devices. An analysis of a porous-matrix-enhanced monochromator crystal is presented. For the particular case investigated, a heat transfer enhancement factor of 5 to 6 was calculated.

  9. Aerodynamic levitation and laser heating: Applications at synchrotron and neutron sources

    Energy Technology Data Exchange (ETDEWEB)

    Hennet, L.; Pozdnyakova, I.; Drewitt, J.W.E.; Leydier, M.; Brassamin, S.; Zanghi, D.; Magazu, S.; Price, D.L. [CEMHTI and University of Orleans, 45071 Orleans Cedex 02 (France); Cristiglio, V.; Kozaily, J.; Fischer, H.E.; Cuello, G.J.; Koza, M. [ILL, BP. 156, 38042 Grenoble Cedex 09 (France); Bytchkov, A. [ESRF, BP. 220, 38043 Grenoble Cedex 09 (France); Thiaudiere, D. [Synchrotron SOLEIL, BP. 48, 91192 Gif-sur-Yvette Cedex (France); Gruner, S. [Institute of Physics, Chemnitz UT, 09107 Chemnitz (Germany); Greaves, G.N. [IMAPS, University of Wales, Aberystwyth, SY23 3BZ (United Kingdom)

    2011-05-15

    Aerodynamic levitation is an effective way to suspend samples which can be heated with CO{sub 2} lasers. The advantages of this container-less technique are the simplicity and compactness of the device, making it possible to integrate it easily in different kinds of experiments. In addition, all types of materials can be used, including metals and oxides. The integration of aerodynamic levitation at synchrotron and neutron sources provides powerful tools to study the structure and dynamics of molten materials. We present here an overview of the existing techniques (electromagnetic levitation, electrostatic levitation, single-axis acoustic levitation, and aerodynamic levitation) and of the developments made at the CEMHTI in Orleans, as well as a few examples of experimental results already obtained. (authors)

  10. Analytical study of the heat loss attenuation by clothing on thermal manikins under radiative heat loads

    NARCIS (Netherlands)

    Hartog, E.A. den; Havenith, G.

    2010-01-01

    For wearers of protective clothing in radiation environments there are no quantitative guidelines available for the effect of a radiative heat load on heat exchange. Under the European Union funded project ThermProtect an analytical effort was defined to address the issue of radiative heat load whil

  11. Transient behavior of heat pipe with thermal energy storage under pulse heat loads

    Science.gov (United States)

    Chang, Ming-, Jr.

    1991-02-01

    Future space missions will require thermal transport devices with the ability to handle transient pulse heat loads. A novel design of a high-temperature axially grooved heat pipe (HP) which incorporates thermal energy storage (TES) to migrate pulse heat loads was presented. A phase-change material (PCM) which is encapsulated in cylindrical containers was used for the thermal energy storage. The transient response of the HP/TES system under two different types of pulse heat loads was studied analytically. The first type is pulse heat loads applied at the heat pipe evaporator, the second type is reversed-pulse heat loads applied at the condenser. In this research, a new three-dimensional alternating-direction-implicit (ADI) method was developed to model the heat conduction through the heat pipe wall and wicks, including the liquid flow in grooves. A very important characteristic of this new ADI method is that it is consistent with physical considerations. Compared with the well-known Brian's and Douglas's ADI methods, this new ADI method had higher accuracy and requires less computer storage. In the numerical solution of heat transfer problems with phase change (Stefan-type problem), a modified Pham's method which includes features from enthalpy and heat capacity methods was used to simulate the melting and solidification processes of the PCG. The vapor flow was assumed quasi-steady and one-dimensional, and was coupled with the evaporation and condensation on the heat pipe inside wall surface and the surfaces of the PCM containers. The transient responses of three different HP/TES configurations were compared: (1) a heat pipe with a large empty cylinder installed in the vapor core, (2) a heat pipe with a large PCM cylinder, and (3) a heat pipe with six small PCM cylinders. From the numerical results, it was found that the PCM is very effective in mitigrating the adverse effect of pulse heat loads. The six small PCM cylinders are more efficient than the large PCM

  12. Cooling Load Estimation in the Building Based On Heat Sources

    Science.gov (United States)

    Chairani; Sulistyo, S.; Widyawan

    2017-05-01

    Heating, ventilation and air conditioning (HVAC) is the largest source of energy consumption. In this research, we discuss cooling load in the room by considering the different heat source and the number of occupancy. Energy cooling load is affected by external and internal heat sources. External cooling load in this discussion include convection outdoor/exterior using the DOE-2 algorithm, calculation of heat using Thermal Analysis Research Program (TARP), and Conduction Transfer Function (CTF). The internal cooling load is calculated based on the activity of the occupants in the office, a number of occupants, heat gain from lighting, and heat gain from electrics equipment. Weather data used is Surakarta weather and design day used is Jakarta design day. We use the ASHRAE standard for building materials and the metabolic of occupants while on the activity. The results show that the number of occupancies have an influence of cooling load. A large number of occupancy will cause the cooling load is great as well.

  13. Interaction of adhered metallic dust with transient plasma heat loads

    NARCIS (Netherlands)

    Ratynskaia, S.; Tolias, P.; I. Bykov,; Rudakov, D.; de Angeli, M.; Vignitchouk, L.; Ripamonti, D.; Riva, G.; Bardin, S.; van der Meiden, H.; Vernimmen, J.; Bystrov, K.; De Temmerman, G.

    2016-01-01

    The first study of the interaction of metallic dust (tungsten, aluminum) adhered on tungsten substrates with transient plasma heat loads is presented. Experiments were carried out in the Pilot-PSI linear device with transient heat fluxes up to 550 MW m −2 and in the DIII-D divertor tokamak. The cent

  14. An Efficient Computation of Coherent Synchrotron Radiation in a Rectangular Chamber, Applied to Resistive Wall Heating

    CERN Document Server

    Warnock, Robert L

    2016-01-01

    We study coherent synchrotron radiation (CSR) in a perfectly conducting vacuum chamber of rectangular cross section, in a formalism allowing an arbitrary sequence of bends and straight sections. We apply the paraxial method in the frequency domain, with a Fourier development in the vertical coordinate but with no other mode expansions. A line charge source is handled numerically by a new method that rids the equations of singularities through a change of dependent variable. The resulting algorithm is fast compared to earlier methods, works for short bunches with complicated structure, and yields all six field components at any space-time point. As an example we compute the tangential magnetic field at the walls. From that one can make a perturbative treatment of the Poynting flux to estimate the energy deposited in resistive walls. The calculation was motivated by a design issue for LCLS-II, the question of how much wall heating from CSR occurs in the last bend of a bunch compressor and the following straight...

  15. 24 CFR 3280.508 - Heat loss, heat gain and cooling load calculations.

    Science.gov (United States)

    2010-04-01

    ... Thermal Protection § 3280.508 Heat loss, heat gain and cooling load calculations. (a) Information, values... Floor Systems 23.15Pipes 23.17Tanks, Vessels, and Equipment 23.18Refrigerated Rooms and Buildings 24... heat-flow paths (“thermal shorts”) shall be explicitly accounted for in the calculation of...

  16. In situ synchrotron IR study relating temperature and heating rate to surface functional group changes in biomass.

    Science.gov (United States)

    Kirtania, Kawnish; Tanner, Joanne; Kabir, Kazi Bayzid; Rajendran, Sharmen; Bhattacharya, Sankar

    2014-01-01

    Three types of woody biomass were investigated under pyrolysis condition to observe the change in the surface functional groups by Fourier transform infrared (FTIR) technique with increasing temperature under two different (5 and 150°C/min) heating rates. The experiments were carried out in situ in the infrared microscopy beamline (IRM) of the Australian Synchrotron. The capability of the beamline made it possible to focus on single particles to obtain low noise measurements without mixing with KBr. At lower heating rate, the surface functional groups were completely removed by 550°C. In case of higher heating rate, a delay was observed in losing the functional groups. Even at a high temperature, significant number of functional groups was retained after the higher heating rate experiments. This implies that at considerably high heating rates typical of industrial reactors, more functional groups will remain on the surface.

  17. Space Heating Load Estimation Procedure for CHP Systems sizing

    Science.gov (United States)

    Vocale, P.; Pagliarini, G.; Rainieri, S.

    2015-11-01

    Due to its environmental and energy benefits, the Combined Heat and Power (CHP) represents certainly an important measure to improve energy efficiency of buildings. Since the energy performance of the CHP systems strongly depends on the fraction of the useful cogenerated heat (i.e. the cogenerated heat that is actually used to meet building thermal demand), in building applications of CHP, it is necessary to know the space heating and cooling loads profile to optimise the system efficiency. When the heating load profile is unknown or difficult to calculate with a sufficient accuracy, as may occur for existing buildings, it can be estimated from the cumulated energy uses by adopting the loads estimation procedure (h-LEP). With the aim to evaluate the useful fraction of the cogenerated heat for different operating conditions in terms of buildings characteristics, weather data and system capacity, the h-LEP is here implemented with a single climate variable: the hourly average dry- bulb temperature. The proposed procedure have been validated resorting to the TRNSYS simulation tool. The results, obtained by considering a building for hospital use, reveal that the useful fraction of the cogenerated heat can be estimated with an average accuracy of ± 3%, within the range of operative conditions considered in the present study.

  18. Short-term heat load forecasting for single family houses

    DEFF Research Database (Denmark)

    Bacher, Peder; Madsen, Henrik; Nielsen, Henrik Aalborg

    2013-01-01

    This paper presents a method for forecasting the load for space heating in a single-family house. The forecasting model is built using data from sixteen houses located in Sønderborg, Denmark, combined with local climate measurements and weather forecasts. Every hour the hourly heat load for each...... characteristics for each house, such as the level of adaptivity and the thermal dynamical response of the building, which is modeled with simple transfer functions. Identification of a model, which is suitable for all the houses, is carried out. The results show that the one-step ahead errors are close to white...

  19. Competitive molecular interaction among paeonol-loaded liposomes: differential scanning calorimetry and synchrotron X-ray diffraction studies.

    Science.gov (United States)

    Wu, Rui-guang; Dai, Jun-dong; Wu, Fu-gen; Zhang, Xiao-hua; Li, Wei-heng; Wang, Yu-rong

    2012-11-15

    Thermotropic phase behavior of 1,2-dipalmitoyl-sn-glycero-3-phosphocholine (DPPC) liposomes containing 5 mol% cholesterol, or 5 mol% stigmasterol, or 5 mol% paeonol have been investigated by differential scanning calorimetry (DSC) and synchrotron X-ray diffraction (XRD) techniques, to investigate the competitive molecular interaction among paeonol-loaded liposomes. The results show that both sterol and paeonol can incorporate into hydrophobic region and interact with acyl chains of DPPC. Both 5 mol% sterols and 5 mol% paeonol can promote the formation of rippled gel phase of DPPC liposomes at room temperature. 5 mol% paeonol can induce the occurrence of phase separation in DPPC liposomes, but 5 mol% cholesterol or 5 mol% stigmasterol cannot induce this phenomenon. Both the repeat distance and the correlation length of paeonol-poor domain are larger than those of coexisted paeonol-rich domain. Both calorimetric data and SAXS patterns show that sterols have more favorable, stabilizing interactions with DPPC than paeonol, implying that high concentrations of sterols will have a negative effect on the loading of paeonol. In addition, calorimetric data show that cholesterol have a little more favorable, stabilizing interactions with DPPC than stigmasterol. The results of this study will play an important role in optimizing the formulation of paeonol-loaded liposomes. Copyright © 2012 Elsevier B.V. All rights reserved.

  20. Particle loading rates for HVAC filters, heat exchangers, and ducts.

    Science.gov (United States)

    Waring, M S; Siegel, J A

    2008-06-01

    The rate at which airborne particulate matter deposits onto heating, ventilation, and air-conditioning (HVAC) components is important from both indoor air quality (IAQ) and energy perspectives. This modeling study predicts size-resolved particle mass loading rates for residential and commercial filters, heat exchangers (i.e. coils), and supply and return ducts. A parametric analysis evaluated the impact of different outdoor particle distributions, indoor emission sources, HVAC airflows, filtration efficiencies, coils, and duct system complexities. The median predicted residential and commercial loading rates were 2.97 and 130 g/m(2) month for the filter loading rates, 0.756 and 4.35 g/m(2) month for the coil loading rates, 0.0051 and 1.00 g/month for the supply duct loading rates, and 0.262 g/month for the commercial return duct loading rates. Loading rates are more dependent on outdoor particle distributions, indoor sources, HVAC operation strategy, and filtration than other considered parameters. The results presented herein, once validated, can be used to estimate filter changing and coil cleaning schedules, energy implications of filter and coil loading, and IAQ impacts associated with deposited particles. The results in this paper suggest important factors that lead to particle deposition on HVAC components in residential and commercial buildings. This knowledge informs the development and comparison of control strategies to limit particle deposition. The predicted mass loading rates allow for the assessment of pressure drop and indoor air quality consequences that result from particle mass loading onto HVAC system components.

  1. Heat loads and cryogenics for HE-LHC

    CERN Document Server

    Delikaris, D

    2011-01-01

    We report preliminary considerations on cryogenics for a higher-energy LHC ("HE-LHC") with about 16.5 TeV beam energy and 20-T dipole magnets. In particular we sketch the heat loads scaled on the proposed principal beam parameters and size the cryogenic plants for different operating temperature of the beam screens.

  2. Cryogenic heat loads analysis from SST-1 plasma experiments

    Science.gov (United States)

    Bairagi, N.; Tanna, V. L.; Pradhan, S.

    2017-02-01

    Cryogenic heat load analysis is an important aspect for stable operation of Tokamaks employing large scale superconducting magnets. Steady State Superconducting Tokamak (SST-1) at IPR is equipped with superconducting magnets system (SCMS) comprising sixteen numbers of modified ‘D’ shaped toroidal field (TF) and nine poloidal field (PF) superconducting coils which are wound using NbTi/Cu based cable-in conduit conductor (CICC). SST-1 magnets operation has flexibility to cool either in two-phase with sub-cooling, two-phase without sub-cooling or single phase (supercritical) helium using a dedicated 1.3 kW helium refrigerator cum liquefier (HRL). Here, we report gross heat losses for integrated TF superconducting magnets of SST-1 during the plasma campaign using cryogenic helium supply/return thermodynamic data from cryoplant. Heat loads mainly comprising of steady state as well as transient loads are smoothly absorbed by SST-1 cryogenic helium plant during plasma experiments. The corresponding heat produced in the coils is totally released to the helium flowing through the TF coils, which in turn is dumped into liquid helium stored in main control Dewar. These results are very useful reference for heat loss analysis for TF as well as PF coils and provides database for future operation of SST-1 machine.

  3. A simple external resistance heating diamond anvil cell and its application for synchrotron radiation x-ray diffraction.

    Science.gov (United States)

    Fan, Dawei; Zhou, Wenge; Wei, Shuyi; Liu, Yonggang; Ma, Maining; Xie, Hongsen

    2010-05-01

    A simple external heating assemblage allowing diamond anvil cell experiments at pressures up to 34 GPa and temperatures up to 653 K was constructed. This cell can be connected to the synchrotron radiation conveniently. The design and construction of this cell are fully described, as well as its applications for x-ray diffraction. Heating is carried out by using an external-heating system, which is made of NiCr resistance wire, and the temperature was measured by a NiCr-NiSi or PtRh-Pt thermocouple. We showed the performance of the new system by introducing the phase transition study of cinnabar (alpha-HgS) and thermal equation of state study of almandine at high pressure and temperature with this cell.

  4. Heat recovery improves part-load turbine sfc

    Energy Technology Data Exchange (ETDEWEB)

    Lester, J.W.; Ware, R.N.

    1982-12-01

    Explains how energy efficiencies can be held almost constant for full- and half-load operation of gas turbine powered mobile generators via heat recovery techniques. Two basic types of gas turbine heat recovery systems are considered: recuperative and regenerative. Effectiveness of a heat recovery device is usually defined as a ratio of the actual air-side temperature rise to the maximum theoretical temperature rise. This theoretical increase would raise the air temperature to that of the gasside temperature. A prototype was prepared, the only modification to the existing model GTP36-51 being incorporation of recuperator ducting and addition of the recuperator itself. The test program's goal was to demonstrate sfc reduction of the order of 40%. Results, corrected to a sea-level, 15C day, adequately demonstrated the improvement. A 36% reduction in fuel consumption at a 30-kW load, and a 32% reduction at a 15-kW load, were demonstrated. For further sfc reduction, increased operating temperatures are essential. Optimized pressure ratio was found to lie between four and five to one. An engine rotor speed of 112,000 rpm was found necessary for the high-temperature component match. Concludes that heat recovery, together with the higher component efficiencies projected for 1983 and beyond, is expected to permit an sfc of the order of 190 g/kWh for devices of the types described.

  5. Dynamic Loading of Carrara Marble in a Heated State

    Science.gov (United States)

    Wong, Louis Ngai Yuen; Li, Zhihuan; Kang, Hyeong Min; Teh, Cee Ing

    2017-06-01

    Useable land is a finite space, and with a growing global population, countries have been exploring the use of underground space as a strategic resource to sustain the growth of their society and economy. However, the effects of impact loading on rocks that have been heated, and hence the integrity of the underground structure, are still not fully understood and has not been included in current design standards. Such scenarios include traffic accidents and explosions during an underground fire. This study aims to provide a better understanding of the dynamic load capacity of Carrara marble at elevated temperatures. Dynamic uniaxial compression tests are performed on Carrara marble held at various temperatures using a split-Hopkinson Pressure Bar (SHPB) setup with varying input force. A customized oven is included in the SHPB setup to allow for testing of the marble specimens in a heated state. After the loading test, a three-wave analysis is performed to obtain the dynamic stress-strain curve of the specimen under loading. The fragments of the failed specimens were also collected and dry-sieved to obtain the particle size distribution. The results reveal that the peak stress of specimens that have been heated is negatively correlated with the heating temperature. However, the energy absorbed by the specimens at peak stress at all temperatures is similar, indicating that a significant amount of energy is dissipated via plastic deformation. Generally, fragment size is also found to show a negative correlation with heating temperature and loading pressure. However, in some cases this relationship does not hold true, probably due to the occurrence of stress shadowing. Linear Elastic Fracture Mechanics has been found to be generally applicable to specimens tested at low temperatures; but at higher temperatures, Elastic-Plastic Fracture Mechanics will give a more accurate prediction. Another contribution of this study is to show that other than the peak stress of the

  6. Surface heat loads on the ITER divertor vertical targets

    Science.gov (United States)

    Gunn, J. P.; Carpentier-Chouchana, S.; Escourbiac, F.; Hirai, T.; Panayotis, S.; Pitts, R. A.; Corre, Y.; Dejarnac, R.; Firdaouss, M.; Kočan, M.; Komm, M.; Kukushkin, A.; Languille, P.; Missirlian, M.; Zhao, W.; Zhong, G.

    2017-04-01

    The heating of tungsten monoblocks at the ITER divertor vertical targets is calculated using the heat flux predicted by three-dimensional ion orbit modelling. The monoblocks are beveled to a depth of 0.5 mm in the toroidal direction to provide magnetic shadowing of the poloidal leading edges within the range of specified assembly tolerances, but this increases the magnetic field incidence angle resulting in a reduction of toroidal wetted fraction and concentration of the local heat flux to the unshadowed surfaces. This shaping solution successfully protects the leading edges from inter-ELM heat loads, but at the expense of (1) temperatures on the main loaded surface that could exceed the tungsten recrystallization temperature in the nominal partially detached regime, and (2) melting and loss of margin against critical heat flux during transient loss of detachment control. During ELMs, the risk of monoblock edge melting is found to be greater than the risk of full surface melting on the plasma-wetted zone. Full surface and edge melting will be triggered by uncontrolled ELMs in the burning plasma phase of ITER operation if current models of the likely ELM ion impact energies at the divertor targets are correct. During uncontrolled ELMs in pre-nuclear deuterium or helium plasmas at half the nominal plasma current and magnetic field, full surface melting should be avoided, but edge melting is predicted.

  7. Transformation Heat Treatment of Rapidly Quenched Nb3A1 Precursor Monitored in situ by High Energy Synchrotron Diffraction

    CERN Document Server

    Scheuerlein, C; Di Michiel, M; Jin, X; Takeuchi, T; Kikuchi, A; Tsuchiya, K; Nakagawa, K; Nakamoto, T

    2013-01-01

    Nb3Al superconductors are studied for use in high field magnets. Fine grained Nb3Al with nearly stoichiometric Al content is obtained by a Rapid Heating Quenching and Transformation (RHQT) process. We describe a non destructive in situ study of the transformation process step of a RHQ Nb3Al precursor wire with ramp rates of either 120 °C/h or 800 °C/h. High energy synchrotron x-ray diffraction measurements show the transformation from a Nb(Al)SS supersaturated solid solution into Nb3Al. When heating with a ramp rate of 120 °C/h a strong reduction of the Nb(Al)SS (110) diffraction peak component is observed when the temperature exceeds 660 °C. Additional diffraction peaks are detectable in the approximate temperature interval 610 °C - 750 °C and significant Nb3Al growth is observed above 730 °C.

  8. High Heat-Load Slits for the PLS Multipole Wiggler

    CERN Document Server

    Gil, Kyehwan; Kim, Young-Chan; Lee, Heung-Soo; Wha Chung, Chin

    2005-01-01

    The HFMX (High Flux Macromolecular X-ray crystallography) beamline under commissioning at Pohang Accelerator Laboratory uses beam from a multipole wiggler for MAD experiment. Two horizontal and vertical slits relevant to high heat load are installed at its front-end. In order to treat high heat load and to reduce beam scattering, the horizontal slit has two glidcop blocks with 10° of vertical inclination and its tungsten blades defining beam size are bolted on backsides of both blocks. The blocks of the slit are adjusted on fixed slides by two actuating bars, respectively. Water through channels machined along the actuating bars cool down the heat load of both blocks. The vertical slit has the same structure as the horizontal slit except its installation direction and angle of vertical inclination. The installed slits show stable operation performance and no alignment for the blocks is required by virtue of a pair of blocks translating on slides. The cooling performance of two slits is also shown to ...

  9. Improving Automation Routines for Automatic Heating Load Detection in Buildings

    Directory of Open Access Journals (Sweden)

    Stephen Timlin

    2012-11-01

    Full Text Available Energy managers use weather compensation data and heating system cut off routines to reduce heating energy consumption in buildings and improve user comfort. These routines are traditionally based on the calculation of an estimated building load that is inferred from the external dry bulb temperature at any point in time. While this method does reduce heating energy consumption and accidental overheating, it can be inaccurate under some weather conditions and therefore has limited effectiveness. There remains considerable scope to improve on the accuracy and relevance of the traditional method by expanding the calculations used to include a larger range of environmental metrics. It is proposed that weather compensation and automatic shut off routines that are commonly used could be improved notably with little additional cost by the inclusion of additional weather metrics. This paper examines the theoretical relationship between various external metrics and building heating loads. Results of the application of an advanced routine to a recently constructed building are examined, and estimates are made of the potential savings that can be achieved through the use of the routines proposed.

  10. Life cycle assessment of base-load heat sources for district heating system options

    Energy Technology Data Exchange (ETDEWEB)

    Ghafghazi, Saeed [University of British Columbia, Vancouver; Sowlati, T. [University of British Columbia, Vancouver; Sokhansanj, Shahabaddine [ORNL; Melin, Staffan [Delta Research Corporation

    2011-03-01

    Purpose There has been an increased interest in utilizing renewable energy sources in district heating systems. District heating systems are centralized systems that provide heat for residential and commercial buildings in a community. While various renewable and conventional energy sources can be used in such systems, many stakeholders are interested in choosing the feasible option with the least environmental impacts. This paper evaluates and compares environmental burdens of alternative energy source options for the base load of a district heating center in Vancouver, British Columbia (BC) using the life cycle assessment method. The considered energy sources include natural gas, wood pellet, sewer heat, and ground heat. Methods The life cycle stages considered in the LCA model cover all stages from fuel production, fuel transmission/transportation, construction, operation, and finally demolition of the district heating system. The impact categories were analyzed based on the IMPACT 2002+ method. Results and discussion On a life-cycle basis, the global warming effect of renewable energy options were at least 200 kgeqCO2 less than that of the natural gas option per MWh of heat produced by the base load system. It was concluded that less than 25% of the upstream global warming impact associated with the wood pellet energy source option was due to transportation activities and about 50% of that was resulted from wood pellet production processes. In comparison with other energy options, the wood pellets option has higher impacts on respiratory of inorganics, terrestrial ecotoxicity, acidification, and nutrification categories. Among renewable options, the global warming impact of heat pump options in the studied case in Vancouver, BC, were lower than the wood pellet option due to BC's low carbon electricity generation profile. Ozone layer depletion and mineral extraction were the highest for the heat pump options due to extensive construction required for these

  11. Covering of heating load of object by using ground heat as a renewable energy source

    Directory of Open Access Journals (Sweden)

    Čenejac Aleksandra R.

    2012-01-01

    Full Text Available Rational use of energy, improving energy performance of buildings and use of renewable energy sources are the most important measures for reducing consumption of non-renewable primary energy (solid, liquid, and gaseous fuels, environmental protection and for the future sustainable development of mankind. In the total primary energy consumption great part is related to building industry, for heating spaces in which people stay and live. Renewable energy sources (RES present natural resources and they are one of the alternatives that allow obtaining heat for heating buildings, and by that they provide a significant contribution to the energy balance of a country. This paper analyzes the participation of ground source as RES, when the vertical (the probe in the ground and horizontal (registry in the ground heat exchangers are used for covering heating load of the building.

  12. Study of a scattering shield in a high heat load monochromator

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Rong, E-mail: rh66@cornell.edu [IMCA-CAT, Hauptman-Woodward Institute (United States); Meron, Mati [CARS, The University of Chicago (United States)

    2013-07-11

    The techniques for the cooling of the first crystal of a monochromator are by now mature and are used routinely to deal with the heat loads resulting from the intense beams generated by third generation synchrotron insertion device sources. However, the thermal stability of said monochromators, which crucially depends on proper shielding of X-ray scattering off the first crystal, remains a serious consideration. This will become even more so in the near future, as many synchrotron facilities are upgrading to higher beam currents and energies. During a recent upgrade of the 17-ID beamline at the APS it was recognized that accurate simulation of the spatial distribution of the power scattered off the first crystal was essential for the understanding and remediation of the observed large temperature increase of the first crystal's scattering shield. The calculation is complex, due to the broad energy spectrum of the undulator and the prevalence of multiple X-ray scattering events within the bulk of the crystal, thus the Monte Carlo method is the natural tool for such a task. A successful simulation was developed, for the purpose of the 17-ID upgrade, and used to significantly improve the design of the first crystal's scattering shield. -- Highlights: • We use the Monte Carlo method to simulate X-ray scattering from monochromator crystals. • Scattered X-ray power on each surface of the scattering shield has been calculated. • Overheating on the original shield is well explained with simulated scattering power. • The thermal stability of the modified scattering shield is satisfactory.

  13. Modeling and Simulation of Heat Transfer in Loaded Continuous Heat Treatment Furnace

    Institute of Scientific and Technical Information of China (English)

    KANG Jin-wu; HUANG Tian-you; PURUSHOTHAMAN Radhakrishnan; WANG Wei-wei; RONG Yi-ming

    2004-01-01

    Continuous furnaces are widely used in the heat treatment of mass-produced parts. However, the heating up process of parts in continuous furnace is still decided by experience. In this paper the heat transfer in the continuous furnace is formulated firstly. The heat balance in each zone is discussed and equations are given. Coupled with the model for heat transfer between workpieces and furnace and the heat transfer in the workload as well presented in the former developed CHT-bf for batch furnaces, a program CHT-cf for continuous furnaces was developed. The model deals with two typical movements of parts: continuous or step by step. The moving speed of parts and load pattern can be optimized based on the calculated temperature distributions and curves, especially, the fastest heated and slowest-heated temperature-distance profiles. A case study is carried out for the heat treatment of a kind of hook-shaped part. The calculated results are analyzed and in good agreement with the measured ones.

  14. Optimization of Boiler Heat Load in Water-Heating Boiler-House

    Directory of Open Access Journals (Sweden)

    B. A. Bayrashevsky

    2009-01-01

    Full Text Available An analytical method for optimization of water-heating boiler loads has been developed on the basis of approximated semi-empirical dependences pertaining to changes of boiler gross efficiency due to its load. A complex (∂tух/∂ξΔξ is determined on the basis of a systematic analysis (monitoring of experimental data and the Y. P. Pecker’s formula for calculation of balance losses q2. This complex makes it possible to set a corresponding correction to a standard value of the boiler gross efficiency due to contamination of heating surfaces.Software means for optimization of water-heating boilers has been developed and it is recommended to be applied under operational conditions.

  15. Series load induction heating inverter state estimator using Kalman filter

    Directory of Open Access Journals (Sweden)

    Szelitzky T.

    2011-12-01

    Full Text Available LQR and H2 controllers require access to the states of the controlled system. The method based on description function with Fourier series results in a model with immeasurable states. For this reason, we proposed a Kalman filter based state estimator, which not only filters the input signals, but also computes the unobservable states of the system. The algorithm of the filter was implemented in LabVIEW v8.6 and tested on recorded data obtained from a 10-40 kHz series load frequency controlled induction heating inverter.

  16. Determination of polycrystal diffraction elastic constants of Ti–2.5Cu by using in situ tensile loading and synchrotron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Maawad, E., E-mail: grossflotbek2000@gmail.com [Helmholtz-Zentrum Geesthacht, Max-Plank-Str. 1, D-21502 Geesthacht (Germany); Brokmeier, H.-G. [Helmholtz-Zentrum Geesthacht, Max-Plank-Str. 1, D-21502 Geesthacht (Germany); Institute of Materials Science and Engineering, Clausthal University of Technology, Agricolastr. 6, D-38678 Clausthal-Zellerfeld (Germany); Zhong, Z.Y.; Al-Hamdany, N.; Salih, M.; Wagner, L. [Institute of Materials Science and Engineering, Clausthal University of Technology, Agricolastr. 6, D-38678 Clausthal-Zellerfeld (Germany); Schell, N. [Helmholtz-Zentrum Geesthacht, Max-Plank-Str. 1, D-21502 Geesthacht (Germany)

    2014-01-31

    Residual stress determination in engineering components from diffraction strain measurements needs reliable diffraction elastic constants (DECs). From this sense, in situ uniaxial tensile loading experiment was performed on alpha titanium alloy Ti–2.5Cu at the HEMS beamline at DESY by means of a monochromatic synchrotron X-ray diffraction. A comparison between measured (polycrystal) and calculated (single crystal) DECs using for example the Kröner model was presented and discussed. The results revealed that the measured DECs slightly differ from the calculated ones. Furthermore, changes in the lattice parameters a and c as well as c/a ratio during tensile loading were also investigated.

  17. High Heat Load Properties of Ultra Fine Grain Tungsten

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Z.; Du, J.; Ge, C. [Lab. of Special Ceramic and P/M, University of Science and Technology, 100083 Beijing (China); Linke, J.; Pintsuk, G. [FZJ-Forschungszentrum Juelich GmbH, Association Euratom-FZJ, Institut fur Plasmaphysik, Postfach 1913, D-52425 Juelich (Germany); Song, S.X. [Research Center on Fusion Materials (RCFM), University of Science and Technology Beijing (USTB), 100083 Beijing (China)

    2007-07-01

    Full text of publication follows: Tungsten is increasingly considered as a promising candidate armour materials facing the plasma in tokamaks for medium to high heat flux components (EAST, ASDEX, ITER). Fabrication tungsten with ultra fine grain size is considered as an effective way to ameliorate some disadvantages of tungsten, such as its brittleness at room temperature. But the research data on the performance of ultra fine grain tungsten is still very limit. In this work, high heat load properties of pure ultra-fine grain tungsten have been studied. The ultra fine grain tungsten samples with average grain size of 0.2 {mu}m, 1 {mu}m and 3 {mu}m were fabricated by resistance sintering under ultra high pressure. The annealing experiments for the investigation of the material resistance against grain growth have been done by annealing samples in a vacuum furnace at different temperature holding for 2 hours respectively. It is found that recrystallization and grain growth occur at heating temperature of 1250 deg. c. The finer the initial grain sizes of tungsten, the smaller its grain growth grain. The effects of transient high thermal loads (off normal events like disruptions) on tungsten surface morphology have been performed in electron beam test facility JUDITH. The thermal loads tests have been carried out with 4 ms pulses at different power density of 0.22, 0.33, 0.44, 0.55 and 0.88 GW/m{sup 2} respectively. Horizontal cracks formed for all tungsten samples at 0.44 GW/m{sup 2}. Particle erosions occurred for tungsten with 3 {mu}m size at 0.33 GW/m{sup 2} and for tungsten with 0.2 and 1 {mu}m size at 0.55 GW/m{sup 2}. The weight loss of tungsten with 0.2, 1 and 3 {mu}m size are 2,0.1,0.6 mg respectively at 0.88 GW/m{sup 2}. The effects of a large number of very short transient repetitive thermal loads (ELM-like) on tungsten surface morphology also have been performed by using a fundamental wave of a YAG laser. It is found that tungsten with 0.2 {mu}m size has

  18. Investigation of vacuum properties of CuCrZr alloy for high-heat-load absorber

    Science.gov (United States)

    Shueh, C.; Chan, C. K.; Chang, C. C.; Sheng, I. C.

    2017-01-01

    The Taiwan Photon Source (TPS) uses high-heat-load (HHL) absorbers to protect downstream ultrahigh-vacuum chambers from overheating. In this work, we propose to use the CuCrZr alloy (ASTM C18150) for the HHL absorber body and the ConFlat flanges. We use the throughput method to measure the thermal outgassing rate and a helium leak detector to verify the vacuum seal between the CuCrZr alloy and stainless-steel flanges. The measured outgassing rate of the CuCrZr alloy was 5.8×10-10 Pa m/s after 72 h of pumping and decreased to 2.0 × 10-10 Pa m/s after 100 h of pumping. The leak rate through the vacuum seal between a CuCrZr flange and a stainless-steel flange was less than 1 × 10-10 Pa m3/s even after mounting and unmounting the flanges ten times and baking them at 250 °C. These results indicate that CuCrZr alloy is suitable for integrating HHL components with ConFlat CuCrZr flanges for the absorption of the synchrotron radiation generated by the TPS.

  19. In situ laser heating and radial synchrotron X-ray diffraction ina diamond anvil cell

    Energy Technology Data Exchange (ETDEWEB)

    Kunz, Martin; Caldwell, Wendel A.; Miyagi, Lowell; Wenk,Hans-Rudolf

    2007-06-29

    We report a first combination of diamond anvil cell radialx-ray diffraction with in situ laser heating. The laser-heating setup ofALS beamline 12.2.2 was modified to allow one-sided heating of a samplein a diamond anvil cell with an 80 W yttrium lithium fluoride laser whileprobing the sample with radial x-ray diffraction. The diamond anvil cellis placed with its compressional axis vertical, and perpendicular to thebeam. The laser beam is focused onto the sample from the top while thesample is probed with hard x-rays through an x-ray transparentboron-epoxy gasket. The temperature response of preferred orientation of(Fe,Mg)O is probed as a test experiment. Recrystallization was observedabove 1500 K, accompanied by a decrease in stress.

  20. In situ laser heating and radial synchrotron X-ray diffraction ina diamond anvil cell

    Energy Technology Data Exchange (ETDEWEB)

    Kunz, Martin; Caldwell, Wendel A.; Miyagi, Lowell; Wenk,Hans-Rudolf

    2007-06-29

    We report a first combination of diamond anvil cell radialx-ray diffraction with in situ laser heating. The laser-heating setup ofALS beamline 12.2.2 was modified to allow one-sided heating of a samplein a diamond anvil cell with an 80 W yttrium lithium fluoride laser whileprobing the sample with radial x-ray diffraction. The diamond anvil cellis placed with its compressional axis vertical, and perpendicular to thebeam. The laser beam is focused onto the sample from the top while thesample is probed with hard x-rays through an x-ray transparentboron-epoxy gasket. The temperature response of preferred orientation of(Fe,Mg)O is probed as a test experiment. Recrystallization was observedabove 1500 K, accompanied by a decrease in stress.

  1. Integrated Behavior of Carbon and Copper Alloy Heat Sink Under Different Heat Loads and Cooling Conditions

    Institute of Scientific and Technical Information of China (English)

    Li Hua; Li Jiangang; Chen Junling; Hu Jiansheng

    2005-01-01

    An actively water-cooled limiter has been designed for the long pulse operation of an HT-7 device, by adopting an integrated structure-doped graphite and a copper alloy heat sink with a super carbon sheet serving as a compliant layer between them. The behaviors of the integrated structure were evaluated in an electron beam facility under different heat loads and cooling conditions. The surface temperature and bulk temperature distribution were carefully measured by optical pyrometers and thermocouples under a steady state heat flux of 1 to 5 MW/m2 and a water flow rate of 3 m3/h, 4.5 m3/h and 6 m3/h, respectively. It was found that the surface temperature increased rapidly with the heat flux rising, but decreased only slightly with the water flow rate rising. The surface temperature reached approximately 1200℃ at 5 MW/m2 of heat flux and 6 ms/h of water flow. The primary experimental results indicate that the integrated design meets the requirements for the heat expelling capacity of the HT-7 device. A set of numerical simulations was also completed, whose outcome was in good accord with the experimental results.

  2. Monochromator on a synchrotron undulator source for liquid surface studies

    DEFF Research Database (Denmark)

    Als-Nielsen, Jens Aage; Freund, A.K.

    1992-01-01

    a monochromator made of a beryllium mosaic crystal using the (002) reflection in Laue geometry placed in undulator beams of DORIS III at the Hamburger Synchrotronstrahlungslabor and of the European Synchrotron Radiation Facility. An analysis of the diffraction properties in terms of mosaic spread, heat load...

  3. An analysis of representative heating load lines for residential HSPF ratings

    Energy Technology Data Exchange (ETDEWEB)

    Rice, C. Keith [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Shen, Bo [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Shrestha, Som S. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2015-07-01

    This report describes an analysis to investigate representative heating loads for single-family detached homes using current EnergyPlus simulations (DOE 2014a). Hourly delivered load results are used to determine binned load lines using US Department of Energy (DOE) residential prototype building models (DOE 2014b) developed by Pacific Northwest National Laboratory (PNNL). The selected residential single-family prototype buildings are based on the 2006 International Energy Conservation Code (IECC 2006) in the DOE climate regions. The resulting load lines are compared with the American National Standards Institute (ANSI)/Air-Conditioning, Heating, and Refrigeration Institute (AHRI) Standard 210/240 (AHRI 2008) minimum and maximum design heating requirement (DHR) load lines of the heating seasonal performance factor (HSPF) ratings procedure for each region. The results indicate that a heating load line closer to the maximum DHR load line, and with a lower zero load ambient temperature, is more representative of heating loads predicted for EnergyPlus prototype residential buildings than the minimum DHR load line presently used to determine HSPF ratings. An alternative heating load line equation was developed and compared to binned load lines obtained from the EnergyPlus simulation results. The effect on HSPF of the alternative heating load line was evaluated for single-speed and two-capacity heat pumps, and an average HSPF reduction of 16% was found. The alternative heating load line relationship is tied to the rated cooling capacity of the heat pump based on EnergyPlus autosizing, which is more representative of the house load characteristics than the rated heating capacity. The alternative heating load line equation was found to be independent of climate for the six DOE climate regions investigated, provided an adjustable zero load ambient temperature is used. For Region IV, the default DOE climate region used for HSPF ratings, the higher load line results in an ~28

  4. Performance of synchrotron X-ray monochromators under heat load Part 1 finite element modeling

    CERN Document Server

    Zhang, L; Migliore, J S; Mocella, V; Ferrero, C; Freund, A K

    2001-01-01

    In this paper we present the details of the finite element modeling (FEM) procedure used to calculate the thermal deformation generated by the X-ray power absorbed in silicon crystals. Different parameters were varied systematically such as the beam footprint on the crystal, the reflection order and the white beam slit settings. Moreover, the influence of various cooling parameters such as the cooling coefficient and the temperature of the coolant were studied. The finite element meshing was carefully optimized to generate a deformation output that could be easily read by a diffraction simulation code. Comparison with the experiments shows that the peak-to-valley slope error calculated by the FEM is an excellent approximation of the rocking curve width for a liquid nitrogen cooled silicon (3 3 3) crystal, and a quite good approximation for significantly deformed silicon (1 1 1) crystals.

  5. Study on heat under dynamic loading of rubber

    Directory of Open Access Journals (Sweden)

    T. I. Igumenova

    2016-01-01

    Full Text Available A number of studies on heat buildup in tire rubber surface scan method samples using a thermal imaging camera. Investigated the exothermic chemical reaction mechanical destruction rubber when loading designs permanent cyclic stretching with deformation of the working zone 50%. Percentage of deformation of the working zone was chosen on the basis of the actual data on the stretch-compression zone "Rusk" tires, which is the maximum level difference of deformation during run-in. Experiment plan provided for periodic relaxation samples of at least 72 hours for more accurate simulation of operation process of structural products. Created and processed data on temperature changes in samples for bar and line profile for rubber compounds with the introduction of nanomodificator (fullerene-containing technical carbon in comparison with the control sample without him. The data obtained reflect the nature of heat depending on the composition of the compound. Identified common patterns of thermal nature of physicochemical process mechanical destruction rubbers. For rubber with nanomodifikatorom there has been an increase in the temperature interval reaction from a minimum to a maximum 2 degrees that is also linked to the rise in the average temperature of the reaction on the histogram also at 2-3 degrees of deformation under the same conditions and the level of cyclic loading. However, the temperature in the control sample that is associated with the beginning of the formation of hardened rubber structures, economies of Mallinza-Petrikeeva, occurs with delay twice compared with modified Fullerenes. Measurement of physic-mechanical indicators selected in the course of testing of samples showed the beginning of formation of structure with increased strength of samples in the sample temperature zone that corresponds to the thermal effect of èndotermičeskomu recombination reactions of macromolecules.

  6. Numerical Model for Conduction-Cooled Current Lead Heat Loads

    CERN Document Server

    White, M J; Brueck, H D; 10.1063/1.4706965

    2012-01-01

    Current leads are utilized to deliver electrical power from a room temperature junction mounted on the vacuum vessel to a superconducting magnet located within the vacuum space of a cryostat. There are many types of current leads used at laboratories throughout the world, however, conduction-cooled current leads are often chosen for their simplicity and reliability. Conduction-cooled leads have the advantage of using common materials, have no superconducting/normal state transition, and have no boil-off vapor to collect. The XFEL (X-Ray Free Electron Laser) magnets are operated at 2 K, which makes vapor-cooled current leads impractical due to the sub-atmospheric bath pressure. This paper presents a numerical model for conduction-cooled current lead heat loads. This model takes into account varying material and fluid thermal properties, varying thicknesses along the length of the lead, heat transfer in the circumferential and longitudinal directions, electrical power dissipation, and the effect of thermal inte...

  7. NETWORK MODEL AND ALGORITHM FOR SOLVING PROBLEM OF OPTIMUM THERMAL LOAD DISTRIBUTION AMONG HEAT-SOURCES OF ENTERPRISE HEATING SYSTEM

    Directory of Open Access Journals (Sweden)

    V. A. Sednin

    2010-01-01

    Full Text Available The paper  presents an algorithm for optimization of thermal load distribution among heat-sources in the system of centralized heat supply. The algorithm can be used while elaborating plans for development of heat supply systems in cities and settlements.

  8. Heat load characteristics and new design using one-coil model superconducting magnets

    Science.gov (United States)

    Jizo, Yoshihiro; Akagi, Hidenari; Yamaguchi, Takashi; Terai, Motoaki; Shinobu, Masatoshi

    Superconducting magnets (SCM) for Maglev trains are vibrated by the electromagnetic force arising from the magnetic field of higher harmonics, which is due to the arrangement of the ground coils. The heat load within the liquid helium temperature region increases by the vibration of the magnets. This paper reports a heat load generation estimation mechanism due to the above-mentioned vibration, as well as effective measures of reducing heat load generation. In addition, we show how a one-coil type SCM can reduce the heat load generation in electromagnetic disturbance tests.

  9. Pulse mitigation and heat transfer enhancement techniques. Volume 4: Transient behavior of heat pipe with thermal energy storage under pulse heat loads

    Science.gov (United States)

    Chow, L. C.; Chang, M. J.

    1992-08-01

    A novel design of a high-temperature axially grooved heat pipe (HP), which utilizes thermal energy storage (TES) to mitigate pulse heat loads, was presented. Phase-change material (PCM) encapsulated in cylindrical containers was used for thermal energy storage. The transient responses of the HP/TES system under two types of pulse heat loads were studied numerically. The first type is pulse heat loads applied at the heat pipe evaporator; the second type is reversed-pulse heat loads applied at the condenser. The transient response of three different HP/TES configurations were compared: (1) a heat pipe with a large empty cylinder installed in the vapor core, (2) a heat pipe with a large PCM cylinder, and (3) a heat pipe with six small PCM cylinders. It was found that the PCM is very effective in mitigating the adverse effect of pulse heat loads. The six small PCM cylinders are more efficient than the large PCM cylinder in relaxing the heat pipe temperature increase under pulse heat loads.

  10. Observations on PVP-protected noble metallic nanoparticle deposits upon heating via in situ synchrotron radiation X-ray diffraction.

    Science.gov (United States)

    Song, Jenn-Ming; Chiou, Guan-Di; Chen, Wei-Ting; Chen, Shih-Yun; Kao, Tzu-Hsuan; Chen, In-Gann; Lee, Hsin-Yi

    2011-03-21

    Through monitoring the evolution of the X-ray diffraction peaks, the phase transformation of PVP-protected Ag and Au nanoparticle deposits (NPDs) on electronic substrates of Cu and Ni upon heating in air was investigated via in situ synchrotron radiation X-ray diffraction. With an increasing temperature, the broad diffraction peak of nano-sized Ag and Au particles with the original average diameters of 4.2 nm and 9.6 nm, respectively, became sharp because of particle coarsening and coalescence. Complex phase transitions among Au, Cu, AuCu(3) and CuO(x) were observed, mainly due to the negative enthalpy of mixing between Au and Cu. The interactions between NPDs and the substrates affected the shift of diffraction peaks to lower angles, caused by thermal expansion and also the temperature for the oxide formation. Compared to Au, Ag NPDs did not form intermetallic compounds with Cu and the formation of copper oxides can also be retarded mainly due to the phase separation feature of the Ag-Cu system.

  11. Daily simulations of urban heat load in Vienna for 2011

    Science.gov (United States)

    Hollosi, Brigitta; Zuvela-Aloise, Maja; Koch, Roland

    2014-05-01

    In this study, the dynamical urban climate model MUKLIMO3 (horizontal resolution of 100 m) is uni-directionally coupled with the operational weather forecast model ALARO-ALADIN of the ZAMG (horizontal resolution of 4.8 km) to simulate the development of the urban heat island in Vienna on a daily basis. The aim is to evaluate the performance of the urban climate model applied for climatological studies in a weather prediction mode. The focus of the investigation is on assessment of the urban heat load during day-time. We used the archived daily forecast data for the summer period in 2011 (April - October) as input data for the urban climate model. The high resolution simulations were initialized with vertical profiles of temperature and relative humidity and prevailing wind speed and direction in the rural area near the city in the early morning hours. The model output for hourly temperature and relative humidity has been evaluated against the monitoring data at 9 weather stations in the area of the city. Additionally, spatial gradients in temperature were evaluated by comparing the grid point values with the data collected during a mobile measuring campaign taken on a multi-vehicle bicycle tour on the 7th of July, 2011. The results show a good agreement with observations on a district scale. Particular challenge in the modeling approach is achieving robust and numerically stable model solutions for different weather situation. Therefore, we analyzed modeled wind patterns for different atmospheric conditions in the summer period. We found that during the calm hot days, due to the inhomogeneous surface and complex terrain, the local-scale temperature gradients can induce strong anomalies, which in turn could affect the circulation on a larger scale. However, these results could not be validated due to the lack of observations. In the following years extreme hot conditions are very likely to occur more frequently and with higher intensity. Combining urban climate

  12. Scaling STI's sapphire cryocooler for applications requiring higher heat loads

    Science.gov (United States)

    Karandikar, Abhijit; Fiedler, Andreas

    2012-06-01

    Superconductor Technologies Inc. (STI) developed the Sapphire cryocooler specifically for the SuperLink® product; a high performance superconducting Radio Frequency (RF) front-end receiver used by wireless carriers such as Verizon Wireless and AT&T to improve network cell coverage and data speeds. STI has built and deployed over 6,000 systems operating 24 hours a day (24/7), 7 days a week in the field since 1999. Sapphire is an integrated free piston Stirling cycle cryocooler with a cooling capacity of 5 Watts at 77 Kelvin (K) with less than 100 Watts (W) input power. It has a field-proven Mean Time Between Failure (MTBF) of well over 1 million hours, requires zero maintenance and has logged over 250 million cumulative runtime hours. The Sapphire cooler is built on a scalable technology platform, enabling the design of machines with cooling capacities greater than 1 kilowatt (kW). This scalable platform also extends the same outstanding attributes as the Sapphire cooler, namely high reliability, zero maintenance, and compact size - all at a competitive cost. This paper will discuss emerging applications requiring higher heat loads and these attributes, describe Sapphire, and show a preliminary concept of a scaled machine with a 100 W cooling capacity.

  13. A combined gray neural network model of seasonal heating load forecast

    Institute of Scientific and Technical Information of China (English)

    QIAOXiaozhuang; YANGChangzhi

    2003-01-01

    Seasonal heating load time sequence has the double trends of increasing and fluctuating, so it''s difficult to select a model to forecast it. In this paper, a combined model of gray model and artificial neural network model was presented to forecast seasonal heating load. A concrete model was established and was verified through actual examples.

  14. Sensitivity Analysis of Depletion Parameters for Heat Load Evaluation of PWR Spent Fuel Storage Pool

    Energy Technology Data Exchange (ETDEWEB)

    Kim, In Young; Lee, Un Chul [Seoul National University, Seoul (Korea, Republic of)

    2011-12-15

    As necessity of safety re-evaluation for spent fuel storage facility has emphasized after the Fukushima accident, accuracy improvement of heat load evaluation has become more important to acquire reliable thermal-hydraulic evaluation results. As groundwork, parametric and sensitivity analyses of various storage conditions for Kori Unit 4 spent fuel storage pool and spent fuel depletion parameters such as axial burnup effect, operation history, and specific heat are conducted using ORIGEN2 code. According to heat load evaluation and parametric sensitivity analyses, decay heat of last discharged fuel comprises maximum 80.42% of total heat load of storage facility and there is a negative correlation between effect of depletion parameters and cooling period. It is determined that specific heat is most influential parameter and operation history is secondly influential parameter. And decay heat of just discharged fuel is varied from 0.34 to 1.66 times of average value and decay heat of 1 year cooled fuel is varied from 0.55 to 1.37 times of average value in accordance with change of specific power. Namely depletion parameters can cause large variation in decay heat calculation of short-term cooled fuel. Therefore application of real operation data instead of user selection value is needed to improve evaluation accuracy. It is expected that these results could be used to improve accuracy of heat load assessment and evaluate uncertainty of calculated heat load.

  15. Heating load of buildings. Room heat from decentralized renewable electricity; Heizlast von Gebaeuden. Raumwaerme aus dezentral erneuerbarem Strom

    Energy Technology Data Exchange (ETDEWEB)

    Hartmann, Frank

    2013-10-15

    If one would like to get the heating load of a building by using peripheral generated electrical energy from photovoltaics or small wind power, one must deal with both the specific building, as well as the heating load, the heating temperature limit and the differentiation of specific heating period for the building. Here, a ground source heat pump with an intelligent energy storage system seems to be the first choice. [German] Moechte man mit dezentral erzeugter elektrischer Energie aus Photovoltaik oder Kleinst-Windkraft die Heizlast eines Gebaeudes besorgen, muss man sich sowohl mit dem spezifischen Gebaeude, als auch mit der Heizlast, der Heizgrenztemperatur und der Differenzierung der spezifischen Heizperiode fuer das Gebaeude auseinandersetzen. Dabei scheint eine erdgekoppelte Waermepumpe mit einem intelligenten Speichersystem die erste Wahl.

  16. Quantitative evaluation of wall heat loads by lost fast ions in the Large Helical Device

    Science.gov (United States)

    Morimoto, Junki; Suzuki, Yasuhiro; Seki, Ryosuke

    2016-10-01

    In fusion plasmas, fast ions are produced by neutral beam injections (NBI), ion cyclotron heating (ICH) and fusion reactions. Some of fast ions are lost from fusion plasmas because of some kinds of drift and instability. These lost fast ions may cause damages on plasma facing components such as divertors and diagnostic instruments in fusion reactors. Therefore, wall heat loads by lost fast ions in the Large Helical Device (LHD) is under investigation. For this purpose, we have been developing the Monte-Carlo code for the quantitative evaluation of wall heat loads based on following the guiding center orbits of fast ions. Using this code, we investigate wall heat loads and hitting points of lost fast ions produced by NBI in LHD. Magnetic field configurations, which depend on beta values, affect orbits of fast ions and wall heat loads. Therefore, the wall heat loads by fast ions in equilibrium magnetic fields including finite beta effect and magnetic islands are quantitatively evaluated. The differences of wall heat loads and particle deposition patterns for cases of the vacuum field and various beta equilibrium fields will be presented at the meeting.

  17. Synchrotron-based microspectroscopic study on the effects of heat treatments on cotyledon tissues in yellow-type canola (Brassica) seeds.

    Science.gov (United States)

    Yu, Peiqiang; Theodoridou, Katerina; Xin, Hangshu; Huang, Pei-Yu; Lee, Yao-Chang; Wood, Bayden R

    2013-07-31

    Synchrotron-based infrared (IR) microspectroscopy is able to reveal structural features of biomaterials within intact tissue at both cellular and molecular levels. Heat-related treatments have been used to improve nutrient availability of canola seeds and meal. However, hitherto, there has been no study on the sensitivity and response of each layer in canola seeds to heat-related treatments. It is not known which layer (epiderm/mucllage, spermoderm, endosperm, or cotyledon) is the most sensitive to heat when heat treatment is applied to the seeds. Traditional wet chemical analysis is unable to answer such questions. The objective of this study is to use synchrotron IR microspectroscopy with multivariate molecular spectral analyses as a research tool to study heat treatment effects in a fast way on the structural changes in cotyledon tissues of yellow-type canola (Brassica) seeds among raw (treatment code "A"), wet heating (autoclaving at 121 °C for 60 min, treatment code "B"), and dry heating (dry roasting at 120 °C for 60 min, treatment code "C"). The hypothesis of this study was that different heat treatments have different heat penetration abilities on cotyledon tissues in yellow-type canola seeds. The multivariate analytical tools principal component analysis (PCA) and agglomerative hierarchal cluster analysis (AHCA) were applied to investigate variance and groupings within the spectral data set [whole spectral range of ca. 4000-650 cm(-1), spectral range of ca. 1300-900 cm(-1) (cellulose or saccarides), spectral range of ca. 1800-1500 cm(-1) (secondary structures of protein) and spectral range of ca. 1500-1300 cm(-1) (bending motion of methylene and methyl group; this change is consistent with the change in the range of ca. 3000-2800 cm(-1))]. The results showed that there were no clear cluster and groups formed in the cotyledon tissues among the three treatments (A, B, and C). There were no clear distinguished responses of the cotyledon tissues to different

  18. Optimal Cooling Load and COP Relationship of a Four-Heat-Reservoir Endoreversible Absorption Refrigeration Cycle

    Directory of Open Access Journals (Sweden)

    Chih Wu

    2004-06-01

    Full Text Available Abstract: On the basis of a four-heat-reservoir endoreversible absorption refrigeration cycle model, another linear heat transfer law [i.e., the heat-flux] is adopted, the fundamental optimal relation between the coefficient of performance (COP and the cooling load, as well as the maximum cooling load and the corresponding COP of the cycle coupled to constant-temperature heat reservoirs are derived by using finite-time thermodynamics or thermodynamic optimization. The optimal distribution of the heat-transfer surface areas is also obtained. Moreover, the effects of the cycle parameters on the COP and the cooling load of the cycle are studied by detailed numerical examples. The results obtained herein are of importance to the optimal design and performance improvement of an absorption refrigeration cycle.

  19. Analysis of the cryogenic system behavior for pulsed heat load in EAST

    Science.gov (United States)

    Hu, L. B.; Zhuang, M.; Zhou, Z. W.; Xia, G. H.

    2014-01-01

    EAST is the first full superconducting fusion device. The plasma is confined by the magnetic fields generated from a large set of superconducting magnets which are made of cable in-conduit conductor (CICC). In operation, these magnets suffer heat loads from thermal and nuclear radiation from the surrounding components and plasma as well as the eddy currents and the AC losses generated within the magnets, together with the heat conduction through supports and the resistive heat generated at the current lead transiting to room temperature. The cryogenic system of our EAST consists of a 2kW/4K helium refrigerator and a distribution system for the cooling of poloidal field (PF) and toroidal field (TF) coils, structures, thermal shields, buslines and current leads. Pulsed heat load is the main difference between the cryogenic system of a full superconducting Tokamak system and other large scale cryogenic systems. The cryogenic system operates in a pulsed heat loads mode requiring the helium refrigerator to remove periodically large heat loads in time. At the same time, the cryogenic system parameters such as helium cooling superconducting magnets, helium refrigerator and helium distribution system are changing. In this paper, the variation range of the parameters of superconducting magnets and refrigerator has been analyzed in the typical plasma discharge mode. The control scheme for the pulsed loads characteristics of the cryogenic system has been proposed, the implementation of which helps to smooth the pulse loads and to improve the stability of the operation of the cryogenic system.

  20. Assessment of Static Heat Loads in the LHC Arc, from the Commissioning of Sector 7-8

    CERN Document Server

    Maglioni, C

    2008-01-01

    This note presents first estimates of the static heat loads in the LHC arc cryostats, evaluated experimentally during the commissioning of sector 7-8 in April 2007. Heat loads to the thermal shielding are estimated from the non-isothermal cooling of the supercritical helium in line E, while heat loads to the 1.9K level of the cold masses are estimated from the internal energy balance during a natural warm-up of the sector in the absence of active cooling. A comparison of the measured heat loads with the budgeted heat loads is then presented and discussed.

  1. Heat Transfer and Impact Load of Steel and Concrete Double Containment

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Tae-Soon; Choi, Choeng-Ryul [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    A CFD analysis technique was applied. The impact load on the concrete wall by aircraft and thermal heat release rate by steel containment were evaluated. We could confirm the structural role of added structure, and in conclusion, the case of adding cooling water tank to SUS containment vessel could obtain bigger impact load dispersion effect.

  2. Mechanical stability of individual austenite grains in TRIP steel studied by synchrotron X-ray diffraction during tensile loading

    Energy Technology Data Exchange (ETDEWEB)

    Blondé, R. [Fundamental Aspects of Materials and Energy, Faculty of Applied Sciences, Delft University of Technology, Mekelweg 15, 2629 JB Delft (Netherlands); Materials Innovation Institute, Mekelweg 2, 2628 CD Delft (Netherlands); Jimenez-Melero, E. [Dalton Cumbrian Facility, The University of Manchester, Westlakes Science and Technology Park, Moor Row, Cumbria, CA24 3HA (United Kingdom); Zhao, L. [Materials Innovation Institute, Mekelweg 2, 2628 CD Delft (Netherlands); Department of Materials Science and Engineering, Delft University of Technology, Mekelweg 2, 2628 CD Delft (Netherlands); Wright, J.P. [European Synchrotron Radiation Facility, 6 Rue Jules Horowitz, BP 220, 38043 Grenoble Cedex (France); Brück, E. [Fundamental Aspects of Materials and Energy, Faculty of Applied Sciences, Delft University of Technology, Mekelweg 15, 2629 JB Delft (Netherlands); Zwaag, S. van der [Novel Aerospace Materials Group, Faculty of Aerospace Engineering, Delft University of Technology, Kluyverweg 1, 2629 HS, Delft (Netherlands); Dijk, N.H. van, E-mail: N.H.vanDijk@tudelft.nl [Fundamental Aspects of Materials and Energy, Faculty of Applied Sciences, Delft University of Technology, Mekelweg 15, 2629 JB Delft (Netherlands)

    2014-11-17

    The stability of individual metastable austenite grains in low-alloyed TRIP steels has been studied during tensile loading using high-energy X-ray diffraction. The carbon concentration, grain volume and grain orientation with respect to the loading direction was monitored for a large number of individual grains in the bulk microstructure. Most austenite grains transform into martensite in a single transformation step once a critical load is reached. The orientation-dependent stability of austenite grains was found to depend on their Schmid factor with respect to the loading direction. Under the applied tensile stress the average Schmid factor decreased from an initial value of 0.44 to 0.41 at 243 MPa. The present study reveals the complex interplay of microstructural parameters on the mechanical stability of individual austenite grains, where the largest grains with the lowest carbon content tend to transform first. Under the applied tensile stress the average carbon concentration of the austenite grains increased from an initial value of 0.90 to 1.00 wt% C at 243 MPa, while the average grain volume of the austenite grains decreased from an initial value of 19 to 15 µm{sup 3} at 243 MPa.

  3. Combined impact of transient heat loads and steady-state plasma exposure on tungsten

    Energy Technology Data Exchange (ETDEWEB)

    Huber, Alexander, E-mail: A.Huber@fz-juelich.de [Forschungszentrum Jülich GmbH, Institut für Energie- und Klimaforschung, 52425 Jülich (Germany); Wirtz, Marius; Sergienko, Gennady; Steudel, Isabel [Forschungszentrum Jülich GmbH, Institut für Energie- und Klimaforschung, 52425 Jülich (Germany); Arakcheev, Aleksey; Burdakov, Aleksander [Budker Institute of Nuclear Physics (BINP), Novosibirsk 630090 (Russian Federation); Esser, Hans Guenter; Freisinger, Michaele; Kreter, Arkadi; Linke, Jochen; Linsmeier, Christian; Mertens, Philippe; Möller, Sören; Philipps, Volker; Pintsuk, Gerald; Reinhart, Michael; Schweer, Bernd [Forschungszentrum Jülich GmbH, Institut für Energie- und Klimaforschung, 52425 Jülich (Germany); Shoshin, Andrey [Budker Institute of Nuclear Physics (BINP), Novosibirsk 630090 (Russian Federation); Terra, Alexis; Unterberg, Bernhard [Forschungszentrum Jülich GmbH, Institut für Energie- und Klimaforschung, 52425 Jülich (Germany)

    2015-10-15

    Highlights: • W-samples under combined loading conditions show a lower damage threshold. • The pre-loaded W-samples show a lower damage threshold due to the D- embrittlement. • Pronounced increase of the D retention has been observed during the combined loads. • Enhanced blister formation has been observed under combined loading conditions. - Abstract: Cracking thresholds and crack patterns in tungsten targets have been studied in recent experiments after repetitive ITER-like ELM heat pulses in combination with plasma exposure in PSI-2 (Γ{sub target} = 2.5–4.0 × 10{sup 21} m{sup −2} s{sup −1}, ion energy on surface E{sub ion} = 60 eV, T{sub e} ≈ 10 eV). The heat pulses were simulated by laser irradiation. A Nd:YAG laser with energy per pulse of up to 32 J and a duration of 1 ms at the fundamental wavelength (λ = 1064 nm, repetition rate 0.5 Hz) was used to irradiate ITER-grade W samples with repetitive heat loads. In contrast to pure thermal exposure with a laser beam where the damage threshold under pure heat loads for ITER-grade W lies between 0.38 and 0.76 GW/m{sup 2}, the experiments with pre-loaded W-samples as well as under combined loading conditions show a lower damage threshold of 0.3 GW/m{sup 2}. This is probably due to deuterium embrittlement and/or a higher defect concentration in a region close to the surface due to supersaturation with deuterium. A pronounced increase in the D retention (more than a factor of five) has been observed during the combined transient heat loads and plasma exposure. Enhanced blister formation has been observed under these combined loading conditions.

  4. Cooling load optimization of an irreversible refrigerator with combined heat transfer

    Directory of Open Access Journals (Sweden)

    M. El Haj Assad

    2013-01-01

    Full Text Available In this work a mathematical model to study the performance of an irreversible refrigerator has been presented with the consideration of heat exchange by combined convection and radiation. The external irreversibility effects due to finite rate heat transfer as well as the effects of internal dissipations have been considered in the analysis. The relation between the cooling load and the coefficient of performance of the refrigerator has been derived. Furthermore an expression for the maximum cooling rate has been derived. The parameters that affect the cooling load have been investigated. The cooling load has been discussed and the effect of internal irreversibility has been investigated.

  5. Diffuse Ceiling Ventilation and the Influence of Room Height and Heat Load Distribution

    DEFF Research Database (Denmark)

    Nielsen, Peter Vilhelm; Vilsbøll, Rasmus W; Liu, Li;

    2015-01-01

    Diffuse ceiling (inlet) ventilation is an air distribution system that supplies air from the entire ceiling surface, giving a low supply velocity. The flow pattern in the room is controlled by the heat sources. The system generates high mixing flow and the air velocities in the room are expected...... with a large room height and it decreases in connection with certain heat load distributions. Room geometries and heat load distributions that are optimal for diffuse ceiling ventilation are discussed. A simplified design procedure is introduced....

  6. Measurements of SCRF cavity dynamic heat load in horizontal test system

    Energy Technology Data Exchange (ETDEWEB)

    DeGraff, B.D.; Bossert, R.J.; Pei, L.; Soyars, W.M.; /Fermilab

    2009-11-01

    The Horizontal Test System (HTS) at Fermilab is currently testing fully assembled, dressed superconducting radio frequency (SCRF) cavities. These cavities are cooled in a bath of superfluid helium at 1.8K. Dissipated RF power from the cavities is a dynamic heat load on the cryogenic system. The magnitude of heat flux from these cavities into the helium is also an important variable for understanding cavity performance. Methods and hardware used to measure this dynamic heat load are presented. Results are presented from several cavity tests and testing accuracy is discussed.

  7. Calorimetric measurement of heat load in full non-inductive LHCD plasmas on TRIAM-1M

    Science.gov (United States)

    Hanada, K.; Shinoda, N.; Sugata, T.; Sasaki, K.; Zushi, H.; Nakamura, K.; Sato, K. N.; Sakamoto, M.; Idei, H.; Hasegawa, M.; Kawasaki, S.; Nakashima, H.; Higashijima, A.; Triam Group

    2007-06-01

    Calorimetric measurements using the temperature increment of cooling-water were carried out to estimate the heat load distribution on the plasma facing components (PFCs) in the limiter discharges on TRIAM-1M. Line averaged electron density, ne, and LH power, PLH, dependences of the heat load on PFCs were measured. The heat load on the limiters was proportional to ne1.5 in the range of ne = 0.2-1.0 × 1019 m-3 and PLH1 in the range of PLH = 0.005-0.09 MW. For PLH > 0.1 MW, the plasma transition to an enhanced current drive (ECD) mode appeared and the ne dependences on the heat load on the limiter moderated. This indicates that the heat flux to scrape-off layer (SOL) region was reduced due to the improvement of the plasma confinement. The up-down asymmetry of the heat load on the vacuum vessel was enhanced in the ECD mode, which may be caused by the increasing of the direct loss of energetic electrons.

  8. Estimation of heat load in waste tanks using average vapor space temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Crowe, R.D.; Kummerer, M.; Postma, A.K.

    1993-12-01

    This report describes a method for estimating the total heat load in a high-level waste tank with passive ventilation. This method relates the total heat load in the tank to the vapor space temperature and the depth of waste in the tank. Q{sub total} = C{sub f} (T{sub vapor space {minus}} T{sub air}) where: C{sub f} = Conversion factor = (R{sub o}k{sub soil}{sup *}area)/(z{sub tank} {minus} z{sub surface}); R{sub o} = Ratio of total heat load to heat out the top of the tank (function of waste height); Area = cross sectional area of the tank; k{sub soil} = thermal conductivity of soil; (z{sub tank} {minus} z{sub surface}) = effective depth of soil covering the top of tank; and (T{sub vapor space} {minus} T{sub air}) = mean temperature difference between vapor space and the ambient air at the surface. Three terms -- depth, area and ratio -- can be developed from geometrical considerations. The temperature difference is measured for each individual tank. The remaining term, the thermal conductivity, is estimated from the time-dependent component of the temperature signals coming from the periodic oscillations in the vapor space temperatures. Finally, using this equation, the total heat load for each of the ferrocyanide Watch List tanks is estimated. This provides a consistent way to rank ferrocyanide tanks according to heat load.

  9. Thermally determining flow and/or heat load distribution in parallel paths

    Energy Technology Data Exchange (ETDEWEB)

    Chainer, Timothy J.; Iyengar, Madhusudan K.; Parida, Pritish R.

    2017-08-01

    A method including obtaining calibration data for at least one sub-component in a heat transfer assembly, wherein the calibration data comprises at least one indication of coolant flow rate through the sub-component for a given surface temperature delta of the sub-component and a given heat load into said sub-component, determining a measured heat load into the sub-component, determining a measured surface temperature delta of the sub-component, and determining a coolant flow distribution in a first flow path comprising the sub-component from the calibration data according to the measured heat load and the measured surface temperature delta of the sub-component.

  10. Thermally determining flow and/or heat load distribution in parallel paths

    Energy Technology Data Exchange (ETDEWEB)

    Chainer, Timothy J.; Iyengar, Madhusudan K.; Parida, Pritish R.

    2016-12-13

    A method including obtaining calibration data for at least one sub-component in a heat transfer assembly, wherein the calibration data comprises at least one indication of coolant flow rate through the sub-component for a given surface temperature delta of the sub-component and a given heat load into said sub-component, determining a measured heat load into the sub-component, determining a measured surface temperature delta of the sub-component, and determining a coolant flow distribution in a first flow path comprising the sub-component from the calibration data according to the measured heat load and the measured surface temperature delta of the sub-component.

  11. Experimental study of plasma energy transfer and material erosion under ELM-like heat loads

    Energy Technology Data Exchange (ETDEWEB)

    Garkusha, I.E., E-mail: garkusha@ipp.kharkov.u [Institute of Plasma Physics of the NSC KIPT, Akademicheskaya 1, 61108 Kharkov (Ukraine); Makhlaj, V.A.; Chebotarev, V.V. [Institute of Plasma Physics of the NSC KIPT, Akademicheskaya 1, 61108 Kharkov (Ukraine); Landman, I. [Forschungszentrum Karlsruhe, IHM, 76021 Karlsruhe (Germany); Tereshin, V.I.; Aksenov, N.N.; Bandura, A.N. [Institute of Plasma Physics of the NSC KIPT, Akademicheskaya 1, 61108 Kharkov (Ukraine)

    2009-06-15

    Main features of plasma-surface interaction and energy transfer to tokamak plasma facing components are studied at different heat loads in ELM simulation experiments with the plasma gun QSPA Kh-50. Repetitive plasma exposures of tungsten, graphite and different combined W-C targets were performed at the pulse duration of 0.25 ms and the heat loads varied in the range 0.2-2.5 MJ/m{sup 2}. The onset of vapor shield in front of the surface was investigated. The evaporation is immediately followed by a saturation of surface heat load if further increasing the impact energy. The presence of graphite essentially decreases the heat flux to the nearby tungsten surface, which is due to the carbon vapor shield. Droplet splashing at the tungsten surface and formation of hot spots on the graphite surface are discussed.

  12. Diffusion-controlled startup of a gas-loaded liquid-metal heat pipe

    Science.gov (United States)

    Ponnappan, R.; Boehman, L. I.; Mahefkey, E. T.

    1990-07-01

    Liquid-metal heat pipes have exhibited difficulties starting up from a frozen-state. Inert gas loading is a possible solution to the frozen-state startup problem. The present study deals with the diffusion-controlled startup analysis and testing of an argon-loaded, 2-m-long, stainless steel-sodium heat pipe of the double-walled type with artery channel and long adiabatic section. A two-dimensional, quasi-steady state, binary vapor-gas diffusion model determined the energy transport rate of vapor at the diffusion front. The analytical solution to the diffusion problem provided the vapor flux, which in turn was used in the one-dimensional transient thermal model of the heat pipe to predict the time rate-of-change of temperature and position of the hot front. The experimental test results successfully demonstrated the startup of a gas-loaded sodium heat pipe and validated the diffusion model of the startup.

  13. Comfort air temperature influence on heating and cooling loads of a residential building

    Science.gov (United States)

    Stanciu, C.; Șoriga, I.; Gheorghian, A. T.; Stanciu, D.

    2016-08-01

    The paper presents the thermal behavior and energy loads of a two-level residential building designed for a family of four, two adults and two students, for different inside comfort levels reflected by the interior air temperature. Results are intended to emphasize the different thermal behavior of building elements and their contribution to the building's external load. The most important contributors to the building thermal loss are determined. Daily heating and cooling loads are computed for 12 months simulation in Bucharest (44.25°N latitude) in clear sky conditions. The most important aspects regarding sizing of thermal energy systems are emphasized, such as the reference months for maximum cooling and heating loads and these loads’ values. Annual maximum loads are encountered in February and August, respectively, so these months should be taken as reference for sizing thermal building systems, in Bucharest, under clear sky conditions.

  14. Optimum load distribution between heat sources based on the Cournot model

    Science.gov (United States)

    Penkovskii, A. V.; Stennikov, V. A.; Khamisov, O. V.

    2015-08-01

    One of the widespread models of the heat supply of consumers, which is represented in the "Single buyer" format, is considered. The methodological base proposed for its description and investigation presents the use of principles of the theory of games, basic propositions of microeconomics, and models and methods of the theory of hydraulic circuits. The original mathematical model of the heat supply system operating under conditions of the "Single buyer" organizational structure provides the derivation of a solution satisfying the market Nash equilibrium. The distinctive feature of the developed mathematical model is that, along with problems solved traditionally within the bounds of bilateral relations of heat energy sources-heat consumer, it considers a network component with its inherent physicotechnical properties of the heat network and business factors connected with costs of the production and transportation of heat energy. This approach gives the possibility to determine optimum levels of load of heat energy sources. These levels provide the given heat energy demand of consumers subject to the maximum profit earning of heat energy sources and the fulfillment of conditions for formation of minimum heat network costs for a specified time. The practical realization of the search of market equilibrium is considered by the example of a heat supply system with two heat energy sources operating on integrated heat networks. The mathematical approach to the solution search is represented in the graphical form and illustrates computations based on the stepwise iteration procedure for optimization of levels of loading of heat energy sources (groping procedure by Cournot) with the corresponding computation of the heat energy price for consumers.

  15. Comparison of ELM heat loads in snowflake and standard divertors

    Energy Technology Data Exchange (ETDEWEB)

    Rognlien, T D; Cohen, R H; Ryutov, D D; Umansky, M V

    2012-05-08

    An analysis is given of the impact of the tokamak divertor magnetic structure on the temporal and spatial divertor heat flux from edge localized modes (ELMs). Two configurations are studied: the standard divertor where the poloidal magnetic field (B{sub p}) varies linearly with distance (r) from the magnetic null and the snowflake where B{sub p} varies quadratrically with r. Both one and two-dimensional models are used to analyze the effect of the longer magnetic field length between the midplane and the divertor plate for the snowflake that causes a temporal dilation of the ELM divertor heat flux. A second effect discussed is the appearance of a broad region near the null point where the poloidal plasma beta can substantially exceed unity, especially for the snowflake configuration during the ELM; such a condition is likely to drive additional radial ELM transport.

  16. Testing and analysis of load-side immersed heat exchangers for solar domestic hot water systems

    Energy Technology Data Exchange (ETDEWEB)

    Farrington, R.B.; Bingham, C.E.

    1987-10-01

    This report describes work to determine the performance of load-side heat exchangers for use in residential solar domestic hot water systems. We measured the performance of four heat exchangers: a smooth coil and a finned coil having heat transfer areas of 2.5 m/sup 2/ (26 ft/sup 2/) and those having areas of 1.7 m/sup 2/ (19 ft/sup 2/). A numerical model using the thermal network program MITAS was constructed, and results were compared to the experimental results. Research showed a smooth coil with only 70% of the surface area of a finned coil performed better than the finned coil. Also, load-side heat exchangers can maintain and enhance stratification in storage tanks, permitting the use of control strategies that take advantage of stratified storage tanks to increase system performance. The analytical model, which agreed reasonably well with the experimental results, was used to vary heat exchanger flow rate and area and initial tank temperature for both a smooth- and a finned-coil heat exchanger. Increasing the heat exchanger flow rate and area results in higher heat transfer rates but not necessarily optimal performance. Lower initial tank temperatures resulted in reduced tank stratification. The smooth heat exchanger outperformed the finned heat exchanger with the same outside surface area. 15 refs., 37 figs., 9 tabs.

  17. Response of NSTX liquid lithium divertor to high heat loads

    Energy Technology Data Exchange (ETDEWEB)

    Abrams, T., E-mail: tabrams@pppl.gov [Princeton Plasma Physics Laboratory, Princeton, NJ 08543 (United States); Jaworski, M.A. [Princeton Plasma Physics Laboratory, Princeton, NJ 08543 (United States); Kallman, J. [Lawrence Livermore National Laboratory, Livermore, CA 94550 (United States); Kaita, R. [Princeton Plasma Physics Laboratory, Princeton, NJ 08543 (United States); Foley, E.L. [Nova Photonics, Inc., Princeton, NJ 08543 (United States); Gray, T.K. [Oak Ridge National Laboratory, Oak Ridge, TN 37831 (United States); Kugel, H. [Princeton Plasma Physics Laboratory, Princeton, NJ 08543 (United States); Levinton, F. [Nova Photonics, Inc., Princeton, NJ 08543 (United States); McLean, A.G. [Lawrence Livermore National Laboratory, Livermore, CA 94550 (United States); Skinner, C.H. [Princeton Plasma Physics Laboratory, Princeton, NJ 08543 (United States)

    2013-07-15

    Samples of the NSTX Liquid Lithium Divertor (LLD) with and without an evaporative Li coating were directly exposed to a neutral beam ex-situ at a power of ∼1.5 MW/m{sup 2} for 1–3 s. Measurements of front face and bulk sample temperature were obtained. Predictions of temperature evolution were derived from a 1D heat flux model. No macroscopic damage occurred when the “bare” sample was exposed to the beam but microscopic changes to the surface were observed. The Li-coated sample developed a lithium hydroxide (LiOH) coating, which did not change even when the front face temperature exceeded the pure Li melting point. These results are consistent with the lack of damage to the LLD surface and imply that heating alone may not expose pure liquid Li if the melting point of surface impurities is not exceeded. This suggests that flow and heat are needed for future PFCs requiring a liquid Li surface.

  18. AUTOMATIC CONTROL SYSTEM OF HEAT PUMP STATION GAS COOLER AT THE WIDE RANGE OF HEAT LOAD

    Directory of Open Access Journals (Sweden)

    Juravleov A.A.

    2008-08-01

    Full Text Available There is examined the structure the of control system of gas cooler of heat pump station, which uses the carbon dioxide as the working fluid in the transctitical thermodynamical cycle. It is analiyed the structure of the complex: heat pump station – district heating system.

  19. Heat load tests of superconducting magnets vibrated electromagnetically for the Maglev train

    Science.gov (United States)

    Ohmori, J.; Nakao, H.; Yamashita, T.; Sanada, Y.; Shudou, M.; Kawai, M.; Fujita, M.; Terai, M.; Miura, A.

    Superconducting magnets on Maglev trains vibrate due to harmonic ripples of electromagnetic flux generated by ground coils. Heat load caused by vibration in the magnet amounted to several tens of watts in the electromagnetic vibration test. This was mainly because a.c. loss was induced in the helium vessel housing the superconducting coil, due to relative vibration between the aluminium thermal shield and the coil. The heat load caused by vibration should be strictly restricted to less than 4W due to limited cryogenic refrigeration capacity. The heat load was tested using electromagnetic flux ripples for a superconducting magnet model of one coil which corresponds to 1/4 of an actual magnet. The flux ripples simulated the 6th harmonic of the actual ground levitation coil. Some ideas to reduce the heat load were tried for the magnet model, such as applying high resistance thermal radiation shielding, increasing rigidity of the vacuum vessel, and using high purity copper plating on the helium vessel. These ideas proved effective, and the maximum heat load due to vibration was held to less than 4 W per magnet for the one coil magnet model.

  20. Characterization of heat loads from mitigated and unmitigated vertical displacement events in DIII-D

    Science.gov (United States)

    Hollmann, E. M.; Commaux, N.; Eidietis, N. W.; Humphreys, D. A.; Jernigan, T. J.; Lasnier, C. J.; Moyer, R. A.; Pitts, R. A.; Sugihara, M.; Strait, E. J.; Watkins, J.; Wesley, J. C.

    2013-06-01

    Experiments have been conducted on the DIII-D tokamak to study the distribution and repeatability of heat loads and vessel currents resulting from vertical displacement events (VDEs). For unmitigated VDEs, the radiated power fraction appears to be of order 50%, with the remaining power dominantly conducted to the vessel walls. Shot-to-shot scatter in heat loads measured at one toroidal location is not large (<±50%), suggesting that toroidal asymmetries in conducted heat loads are not large. Conducted heat loads are clearly observed during the current quench (CQ) of both mitigated and unmitigated disruptions. Significant poloidal asymmetries in heat loads and radiated power are often observed in the experiments but are not yet understood. Energy dissipated resistively in the conducting walls during the CQ appears to be small (<5%). The mitigating effect of neon massive gas injection (MGI) as a function of MGI trigger delay has also been studied. Improved mitigation is observed as the MGI trigger delay is decreased. For sufficiently early MGI mitigation, close to 100% radiated energy and a reduction of roughly a factor 2 in vessel forces is achieved.

  1. Characterization of heat loads from mitigated and unmitigated vertical displacement events in DIII-D

    Energy Technology Data Exchange (ETDEWEB)

    Hollmann, E. M.; Moyer, R. A. [University of California-San Diego, La Jolla, California 92093 (United States); Commaux, N.; Jernigan, T. J. [Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831 (United States); Eidietis, N. W.; Humphreys, D. A.; Strait, E. J.; Wesley, J. C. [General Atomics, San Diego, California 92186 (United States); Lasnier, C. J. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States); Pitts, R. A.; Sugihara, M. [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul Lez Durance (France); Watkins, J. [Sandia National Laboratory, Albuquerque, New Mexico 87185 (United States)

    2013-06-15

    Experiments have been conducted on the DIII-D tokamak to study the distribution and repeatability of heat loads and vessel currents resulting from vertical displacement events (VDEs). For unmitigated VDEs, the radiated power fraction appears to be of order 50%, with the remaining power dominantly conducted to the vessel walls. Shot-to-shot scatter in heat loads measured at one toroidal location is not large (<±50%), suggesting that toroidal asymmetries in conducted heat loads are not large. Conducted heat loads are clearly observed during the current quench (CQ) of both mitigated and unmitigated disruptions. Significant poloidal asymmetries in heat loads and radiated power are often observed in the experiments but are not yet understood. Energy dissipated resistively in the conducting walls during the CQ appears to be small (<5%). The mitigating effect of neon massive gas injection (MGI) as a function of MGI trigger delay has also been studied. Improved mitigation is observed as the MGI trigger delay is decreased. For sufficiently early MGI mitigation, close to 100% radiated energy and a reduction of roughly a factor 2 in vessel forces is achieved.

  2. Heat Loads Due to Small Penetrations in Multilayer Insulation Blankets

    Science.gov (United States)

    Johnson, W. L.; Heckle, K. W.; Fesmire, J. E.

    2017-01-01

    The main penetrations (supports and piping) through multilayer insulation systems for cryogenic tanks have been previously addressed by heat flow measurements. Smaller penetrations due to fasteners and attachments are now experimentally investigated. The use of small pins or plastic garment tag fasteners to each the handling and construction of multilayer insulation (MLI) blankets goes back many years. While it has long been understood that penetrations and other discontinuities degrade the performance of the MLI blanket, quantification of this degradation has generally been lumped into gross performance multipliers (often called degradation factors or scale factors). Small penetrations contribute both solid conduction and radiation heat transfer paths through the blanket. The conduction is down the stem of the structural element itself while the radiation is through the hole formed during installation of the pin or fastener. Analytical models were developed in conjunction with MLI perforation theory and Fouriers Law. Results of the analytical models are compared to experimental testing performed on a 10 layer MLI blanket with approximately 50 small plastic pins penetrating the test specimen. The pins were installed at 76-mm spacing inches in both directions to minimize the compounding of thermal effects due to localized compression or lateral heat transfer. The testing was performed using a liquid nitrogen boil-off calorimeter (Cryostat-100) with the standard boundary temperatures of 293 K and 78 K. Results show that the added radiation through the holes is much more significant than the conduction down the fastener. The results are shown to be in agreement with radiation theory for perforated films.

  3. Erosion of newly developed CFCs and Be under disruption heat loads

    Science.gov (United States)

    Nakamura, K.; Akiba, M.; Araki, M.; Dairaku, M.; Sato, K.; Suzuki, S.; Yokoyama, K.; Linke, J.; Duwe, R.; Bolt, H.; Roedig, M.

    1996-10-01

    An evaluation of the erosion under disruption heat loads is very important to the lifetime prediction of divertor armour tiles of next fusion devices such as ITER. In particular, erosion data on CFCs (carbon fiber reinforced composites) and beryllium (Be) as the armour materials is urgently required in the ITER design. For CFCs, high heat flux experiments on the newly developed CFCs with high thermal conductivity have been performed under the heat flux of around 800-2000 MW/m 2 and the pulse length of 2-5 ms in JAERI electron beam irradiation systems (JEBIS). As a result, the weight losses of B 4C doped CFCs after heating were almost same to those of the non doped CFC up to 5 wt% boron content. For Be, we have carried out our first disruption experiments on S65/C grade Be specimens in the Juelich divertor test facility in hot cells (JUDITH) facility as a frame work of the J—EU collaboration. The heating conditions were heat loads of 1250-5000 MW/m 2 for 2-8 ms, and the heated area was 3 × 3 mm 2. As a result, the protuberances of the heated area of Be were observed under the lower heat flux.

  4. Simulation of electron-cloud heat load for the cold arcs of the Large Hadron Collider

    CERN Document Server

    Maury Cuna, Humberto; Rumolo, Giovanni; Zimmermann, Frank

    2013-01-01

    The heat load due to the electron cloud in the Large Hadron Collider (LHC) cold arcs is a concern for its performance near and beyond nominal beam current. We report the results of simulation studies, which examine the electron-cloud induced heat load for different values of low-energy electron reflectivity and secondary emission yield at injection energy, as well as at beam energies of 4 TeV and 7 TeV, for two different bunch spacing: 25 ns and 50 ns. Benchmarking the simulations against heat-load observations at different beam energies and bunch spacings allows an estimate of the secondary emission yield in the cold arcs of the LHC and of its evolution as a function of time.

  5. Long-Haul Truck Sleeper Heating Load Reduction Package for Rest Period Idling

    Energy Technology Data Exchange (ETDEWEB)

    Lustbader, Jason Aaron; Kekelia, Bidzina; Tomerlin, Jeff; Kreutzer, Cory J.; Yeakel, Skip; Adelman, Steven; Luo, Zhiming; Zehme, John

    2016-04-05

    Annual fuel use for sleeper cab truck rest period idling is estimated at 667 million gallons in the United States, or 6.8% of long-haul truck fuel use. Truck idling during a rest period represents zero freight efficiency and is largely done to supply accessory power for climate conditioning of the cab. The National Renewable Energy Laboratory's CoolCab project aims to reduce heating, ventilating, and air conditioning (HVAC) loads and resulting fuel use from rest period idling by working closely with industry to design efficient long-haul truck thermal management systems while maintaining occupant comfort. Enhancing the thermal performance of cab/sleepers will enable smaller, lighter, and more cost-effective idle reduction solutions. In addition, if the fuel savings provide a one- to three-year payback period, fleet owners will be economically motivated to incorporate them. For candidate idle reduction technologies to be implemented by original equipment manufacturers and fleets, their effectiveness must be quantified. To address this need, several promising candidate technologies were evaluated through experimentation and modeling to determine their effectiveness in reducing rest period HVAC loads. Load reduction strategies were grouped into the focus areas of solar envelope, occupant environment, conductive pathways, and efficient equipment. Technologies in each of these focus areas were investigated in collaboration with industry partners. The most promising of these technologies were then combined with the goal of exceeding a 30% reduction in HVAC loads. These technologies included 'ultra-white' paint, advanced insulation, and advanced curtain design. Previous testing showed more than a 35.7% reduction in air conditioning loads. This paper describes the overall heat transfer coefficient testing of this advanced load reduction technology package that showed more than a 43% reduction in heating load. Adding an additional layer of advanced insulation

  6. Long-Haul Truck Sleeper Heating Load Reduction Package for Rest Period Idling: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Lustbader, Jason; Kekelia, Bidzina; Tomerlin, Jeff; Kreutzer, Cory; Adelman, Steve; Yeakel, Skip; Luo, Zhiming; Zehme, John

    2016-03-24

    Annual fuel use for sleeper cab truck rest period idling is estimated at 667 million gallons in the United States, or 6.8% of long-haul truck fuel use. Truck idling during a rest period represents zero freight efficiency and is largely done to supply accessory power for climate conditioning of the cab. The National Renewable Energy Laboratory's CoolCab project aims to reduce heating, ventilating, and air conditioning (HVAC) loads and resulting fuel use from rest period idling by working closely with industry to design efficient long-haul truck thermal management systems while maintaining occupant comfort. Enhancing the thermal performance of cab/sleepers will enable smaller, lighter, and more cost-effective idle reduction solutions. In addition, if the fuel savings provide a one- to three-year payback period, fleet owners will be economically motivated to incorporate them. For candidate idle reduction technologies to be implemented by original equipment manufacturers and fleets, their effectiveness must be quantified. To address this need, several promising candidate technologies were evaluated through experimentation and modeling to determine their effectiveness in reducing rest period HVAC loads. Load reduction strategies were grouped into the focus areas of solar envelope, occupant environment, conductive pathways, and efficient equipment. Technologies in each of these focus areas were investigated in collaboration with industry partners. The most promising of these technologies were then combined with the goal of exceeding a 30% reduction in HVAC loads. These technologies included 'ultra-white' paint, advanced insulation, and advanced curtain design. Previous testing showed more than a 35.7% reduction in air conditioning loads. This paper describes the overall heat transfer coefficient testing of this advanced load reduction technology package that showed more than a 43% reduction in heating load. Adding an additional layer of advanced insulation

  7. Long-Haul Truck Sleeper Heating Load Reduction Package for Rest Period Idling

    Energy Technology Data Exchange (ETDEWEB)

    Lustbader, Jason; Kekelia, Bidzina; Tomerlin, Jeff; Kreutzer, Cory; Adelman, Steve; Yeakel, Skip; Luo, Zhiming; Zehme, John

    2016-06-01

    Annual fuel use for sleeper cab truck rest period idling is estimated at 667 million gallons in the United States, or 6.8% of long-haul truck fuel use. Truck idling during a rest period represents zero freight efficiency and is largely done to supply accessory power for climate conditioning of the cab. The National Renewable Energy Laboratory's CoolCab project aims to reduce heating, ventilating, and air conditioning (HVAC) loads and resulting fuel use from rest period idling by working closely with industry to design efficient long-haul truck thermal management systems while maintaining occupant comfort. Enhancing the thermal performance of cab/sleepers will enable smaller, lighter, and more cost-effective idle reduction solutions. In addition, if the fuel savings provide a one- to three-year payback period, fleet owners will be economically motivated to incorporate them. For candidate idle reduction technologies to be implemented by original equipment manufacturers and fleets, their effectiveness must be quantified. To address this need, several promising candidate technologies were evaluated through experimentation and modeling to determine their effectiveness in reducing rest period HVAC loads. Load reduction strategies were grouped into the focus areas of solar envelope, occupant environment, conductive pathways, and efficient equipment. Technologies in each of these focus areas were investigated in collaboration with industry partners. The most promising of these technologies were then combined with the goal of exceeding a 30% reduction in HVAC loads. These technologies included 'ultra-white' paint, advanced insulation, and advanced curtain design. Previous testing showed more than a 35.7% reduction in air conditioning loads. This paper describes the overall heat transfer coefficient testing of this advanced load reduction technology package that showed more than a 43% reduction in heating load. Adding an additional layer of advanced insulation

  8. Value analysis of district heating system with gas-fired peak load boiler in secondary network

    Institute of Scientific and Technical Information of China (English)

    郑雪晶; 穆振英

    2009-01-01

    In district heating(DH) system with gas-fired peak load regulating boiler in the secondary network,by prolonging run time of base load plants under rated condition,the mean energy efficiency could be increased. The fuels of the system,including coal and gas,would cause different environmental impacts. Meanwhile,the reliability of the heating networks would be changed because the peak load regulating boiler could work as a standby heat source. A model for assessment of heating system was established by value analysis to optimize this kind of system. Energy consumption,greenhouse gas emission,pollution emission and system reliability were selected as functional assessment indexes in the model. Weights of each function were determined by analytical hierarchy process (AHP) and experts consultation. Life cycle cost was used as the cost in the model. A real case as an example was discussed to obtain the optimal base load ratio. The result shows that the optimal base load ratio of the case is 0.77.

  9. Sorbate rearrangement and cation migration in HFC-134 loaded NaY zeolite: a temperature dependent synchrotron powder diffraction study

    Energy Technology Data Exchange (ETDEWEB)

    Gualtieri, A.F. [Dipt. di Scienze della Terra, Univ. di Modena e R.E. (Italy); Norby, P. [Chemistry Dept., Univ. of Aarhus (Denmark); Grey, C.P. [Chemistry Dept., SUNY Stony Brook, NY (United States); Hanson, J.C. [Chemistry Dept., Brookhaven National Lab., Upton, NY (United States)

    2004-07-01

    The HFC-134/NaY binding has been monitored by temperature dependent X-ray powder diffraction. Diffraction patterns were obtained as a function of different loading levels to investigate the rearrangement of the cations and of the HFC-134 molecules, in the temperature range 100-230 K. In situ real-time data were collected using a Translating Imaging Plate System (TIPS) at the NSLS (USA). Rietveld structure refinements were performed for the HFC-134 (32 molecules per unit cell [m/uc=molecules per unit cell] or 4 molecules per supercage [m/sc=molecules per supercage]) using data collected from 100 to 230 K. A phase transition is observed at about 180 K (A to B phase transition) where a disordering of the HFC-134 molecule takes place and modification of its surrounding due to Na{sup +} migrations is observed. These results are preliminary and the experiment with the 32 m/uc should be repeated in order to assess whether the observed effect is reproducible. (orig.)

  10. Heat load of a GaAs photocathode in an SRF electron gun

    Institute of Scientific and Technical Information of China (English)

    WANG Er-Dong; ZHAO Kui; J(o)rg Kewisch; Ilan Ben-Zvi; Andrew Burrill; Trivini Rao; WU Qiong; Animesh Jain; Ramesh Gupta; Doug Holmes

    2011-01-01

    A great deal of effort has been made over the last decades to develop a better polarized electron source for high energy physics. Several laboratories operate DC guns with a gallium arsenide photocathode, which yield a highly polarized electron beam. However, the beam's emittance might well be improved by using a superconducting radio frequency (SRF) electron gun, which delivers beams of a higher brightness than that from DC guns because the field gradient at the cathode is higher. SRF guns with metal and CsTe cathodes have been tested successfully. To produce polarized electrons, a Gallium-Arsenide photo-cathode must be used: an experiment to do so in a superconducting RF gun is under way at BNL. Since a bulk gallium arsenide (GaAs) photocathode is normal conducting, a problem arises from the heat load stemming from the cathode. We present our measurements of the electrical resistance of GaAs at cryogenic temperatures, a prediction of the heat load and verification by measuring the quality factor of the gun with and without the cathode at 2 K. We simulate heat generation and flow from the GaAs cathode using the ANSYS program. By following the findings with the heat load model, we designed and fabricated a new cathode holder (plug) to decrease the heat load from GaAs.

  11. Simulation of Be armour cracking under ITER-like transient heat loads [in press

    OpenAIRE

    Pestchanyi, S.; Spilker, B.; Bazylev, B.

    2016-01-01

    Simulation of beryllium cracking under action of multiple severe surface heatings has been performed using the PEGASUS-3D code and verified by experiments in the JUDITH 1 facility. Analysis of the results has revealed beryllium thermo conductivity degradation under action of repetitive pulsed heat load due to accumulation of the cracks in the surface layer. Thermo conductivity degradation is found to be at least 4 times after 100 pulses in JUDITH 1 facility. An analytical model for the Be cra...

  12. Simulation of Be armour cracking under ITER-like transient heat loads

    OpenAIRE

    Pestchanyi, S.; Spilker, B.; Bazylev, B

    2016-01-01

    Simulation of beryllium cracking under action of multiple severe surface heatings has been performed using the PEGASUS-3D code and verified by experiments in the JUDITH 1 facility. Analysis of the results has revealed beryllium thermo conductivity degradation under action of repetitive pulsed heat load due to accumulation of the cracks in the surface layer. Thermo conductivity degradation is found to be at least 4 times after 100 pulses in JUDITH 1 facility. An analytical model for the Be cra...

  13. Effect of particle loading on heat transfer enhancement in a gas-solid suspension cross flow

    Institute of Scientific and Technical Information of China (English)

    周劲松; 骆仲泱; 高翔; 倪明江; 岑可法

    2002-01-01

    Heat transfer between gas-solid multiphase flow and tubes occurs in m a ny industry processes, such as circulating fluidized bed process, pneumatic conv eying process, chemical process, drying process, etc. This paper focuses on the influence of the presence of particles on the heat transfer between a tube and g as-solid suspension. The presence of particles causes positive enhancement of h e at transfer in the case of high solid loading ratio, but heat transfer reduction has been found for in the case of very low solid loading ratio (Ms of les s than 0.05 kg/kg). A useful correlation incorporating solid loading ratio, particle s ize and flow Reynolds number was derived from experimental data. In addition, th e k-ε two-equation model and the Fluctuation-Spectrum- Random-Trajecto ry Model ( FSRT Model) are used to simulate the flow field and heat transfer of the gas-ph a se and the solid-phase, respectively. Through coupling of the two phases the mo d el can predict the local and total heat transfer characteristics of tube in gas - solid cross flow. For the total heat transfer enhancement due to particles loadi ng the model predictions agreed well with experimental data.

  14. Surface modifications of W divertor components for EAST during exposure to high heat loads with He

    Energy Technology Data Exchange (ETDEWEB)

    Li, C., E-mail: lichun10@mails.tsinghua.edu.cn [Laboratory of Advanced Materials, School of Materials Science and Engineering, Tsinghua University, Beijing 100084 (China); Greuner, H. [Max Planck Institute for Plasma Physics, Boltzmannstr. 2, 85748 Garching (Germany); Yuan, Y. [School of Physics and Nuclear Energy Engineering, Beihang University, Beijing 100191 (China); Zhao, S.X.; Luo, G.N. [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui 230031 (China); Böswirth, B. [Max Planck Institute for Plasma Physics, Boltzmannstr. 2, 85748 Garching (Germany); Fu, B.Q.; Jia, Y.Z. [Laboratory of Advanced Materials, School of Materials Science and Engineering, Tsinghua University, Beijing 100084 (China); Liu, X. [Southwestern Institute of Physics, Chengdu, Sichuan 610041 (China); Liu, W., E-mail: liuw@mail.tsinghua.edu.cn [Laboratory of Advanced Materials, School of Materials Science and Engineering, Tsinghua University, Beijing 100084 (China)

    2015-08-15

    Flat-type W/Cu plasma-facing components have been developed for the new generation divertor of the Chinese Experimental Advanced Superconducting Tokamak. Surface modifications of such actively water-cooled W components following short and long pulse high heat loading coupled with He particle loads with fluence of 3 × 10{sup 22} m{sup −2} have been investigated. An adiabatically loaded W block was investigated as a comparison and exposed to short pulse loads. Blistering was observed on all sample surfaces, but was less pronounced on the components than on the W block, due to the significant lower surface temperature caused by active cooling. For components, longer pulse loads gave rise to a rougher surface. Furthermore, most blisters on components are found to be less than 1 μm in diameter, with just a very few blisters larger than 1 μm, observed only in some near 〈1 1 1〉 grains.

  15. Simulation of Be armour cracking under ITER-like transient heat loads

    Directory of Open Access Journals (Sweden)

    S. Pestchanyi

    2016-12-01

    Full Text Available Simulation of beryllium cracking under action of multiple severe surface heatings has been performed using the PEGASUS-3D code and verified by experiments in the JUDITH 1 facility. Analysis of the results has revealed beryllium thermo conductivity degradation under action of repetitive pulsed heat load due to accumulation of the cracks in the surface layer. Thermo conductivity degradation is found to be at least 4 times after 100 pulses in JUDITH 1 facility. An analytical model for the Be cracking threshold under action of arbitrary heat pulses has been developed.

  16. Influence of resonant magnetic perturbations on transient heat load deposition and fast ion losses

    Energy Technology Data Exchange (ETDEWEB)

    Rack, Michael Thomas

    2014-07-11

    Thermonuclear fusion is the energy conversion process which keeps the sun shining. For the last six decades, researchers have been investigating the physics involved in order to enable the usage of this energy supply on Earth. The most promising candidates for fusion power plants are based on magnetic confinement of plasma to provide the ideal conditions for efficient thermonuclear fusion in well controlled surroundings. One important aspect is the control of instabilities that occur in the edge region of the plasma and lead to an ejection of huge amounts of energy. Magnetic perturbation fields which are resonant in the plasma edge are found to modify the plasma favourably and reduce the impact of these instabilities. This dissertation focuses on the effects of resonant magnetic perturbation fields on the ejected energy as well as on the drawbacks of these perturbation fields. The transient energy ejection which is triggered by the instabilities causes extreme heat loads on the wall components in fusion devices. Therefore, it is crucial to understand how resonant magnetic perturbation fields affect the heat load deposition. Furthermore, the impact of resonant magnetic perturbation fields on the confinement of fast ions is an important aspect as fast ions are still required to be well confined in order to avoid additional wall loads and increase the fusion efficiency. Recent upgrades on the Joint European Torus allow for a detailed study of the heat load deposition profiles caused by transient events. Throughout this work, the new features are used for the study of the modifications of the transient heat load depositions that occur if resonant magnetic perturbation fields are applied. This leads to a further understanding of the processes involved during the plasma edge instabilities. Additionally, an alternative method using lower hybrid waves for applying resonant magnetic perturbations is investigated. Furthermore, a new diagnostic, capable of detecting fast ion

  17. Effect of particle loading on heat transfer enhancement in a gas-solid suspension cross flow

    Institute of Scientific and Technical Information of China (English)

    周劲松; 骆仲泱; 高翔; 倪明江; 岑可法

    2002-01-01

    Heat transfer between gas-solid multiphase flow and tubes occurs in many industry processes, such as circulating fluidized bed process, pneumatic conveying process, chemical process, drying process, etc. (This paper focuses on the influence of the presence of particles on the heat transfer between a tube and gas-solid sus-pension. The presence of particles causes positive enhancement of heat transfer in the case of high solid loading ratio, but heat transfer reduction has been found for in the case of very low soliding ratio (Ms of less than 0.05 kg/kg). A usefial correlation ineorpomting solid lolling ratio, particle size and flow Reytmlds number was derived from experimental data. In addition, the κ-ε two-equation model and the Fluctuation-Spectrum-Random-Trajectory Model (FSRT Model) are used to simulate the flow field and heat transit of the gas-phase and the solid-phase, respectively. Through coupling of the two phases the model can predict the local and total heat transfer characteristics of tube in gas-solid cross flow. For the total heat transfer enhancement due to particles loading the model predictions agreed well wih experimental data.

  18. Fast heating and cooling in nanoimprint using a spring-loaded adapter in a preheated press

    DEFF Research Database (Denmark)

    Schift, Helmut; Bellini, Sandro; Gobrecht, Jens

    2007-01-01

    By using a spring-loaded adapter, instant heating and cooling of wafer-type substrates was implemented in standard hot embossing equipment. This was possible by using the well-known concept of a clamped stack of stamp and substrate, pre-assembled in an alignment fixture. A number of thermoplastic...

  19. Cluster analysis of residential heat load profiles and the role of technical and household characteristics

    DEFF Research Database (Denmark)

    Carmo, Carolina; Christensen, Toke Haunstrup

    2016-01-01

    segments; a main cluster with a relatively constant load profile and a minor cluster with a more distinct variation during the day. The difference between the clusters is primarily correlated with building characteristics like floor area, building year and type of space heating distribution system, while...

  20. Technology Solutions Case Study: Calculating Design Heating Loads for Superinsulated Buildings

    Energy Technology Data Exchange (ETDEWEB)

    None

    2015-08-01

    Designing a superinsulated home has many benefits including improved comfort, reduced exterior noise penetration, lower energy bills, and the ability to withstand power and fuel outages under much more comfortable conditions than a typical home. Extremely low heating and cooling loads equate to much smaller HVAC equipment than conventionally required. Sizing the mechanical system to these much lower loads reduces first costs and the size of the distribution system needed. While these homes aren't necessarily constructed with excessive mass in the form of concrete floors and walls, the amount of insulation and the increase in the thickness of the building envelope can lead to a mass effect, resulting in the structures ability to store much more heat than a code built home. This results in a very low thermal inertia making the building much less sensitive to drastic temperature swings thereby decreasing the peak heating load demand. Alternative methods that take this inertia into account along with solar and internal gains result in smaller more appropriate design loads than those calculated using Manual J version 8. During the winter of 2013/2014, the Consortium for Advanced Residential Buildings team monitored the energy use of three homes in climate zone 6 in an attempt to evaluate the accuracy of two different mechanical system sizing methods for low load homes. Based on the results, it is recommended that internal and solar gains be included and some credit for thermal inertia be used in sizing calculations for superinsulated homes.

  1. Study on mitigation of pulsed heat load for ITER cryogenic system

    Science.gov (United States)

    Peng, N.; Xiong, L. Y.; Jiang, Y. C.; Tang, J. C.; Liu, L. Q.

    2015-03-01

    One of the key requirements for ITER cryogenic system is the mitigation of the pulsed heat load deposited in the magnet system due to magnetic field variation and pulsed DT neutron production. As one of the control strategies, bypass valves of Toroidal Field (TF) case helium loop would be adjusted to mitigate the pulsed heat load to the LHe plant. A quasi-3D time-dependent thermal-hydraulic analysis of the TF winding packs and TF case has been performed to study the behaviors of TF magnets during the reference plasma scenario with the pulses of 400 s burn and repetition time of 1800 s. The model is based on a 1D helium flow and quasi-3D solid heat conduction model. The whole TF magnet is simulated taking into account thermal conduction between winding pack and case which are cooled separately. The heat loads are given as input information, which include AC losses in the conductor, eddy current losses in the structure, thermal radiation, thermal conduction and nuclear heating. The simulation results indicate that the temperature variation of TF magnet stays within the allowable range when the smooth control strategy is active.

  2. Experimental temperature distribution and heat load characteristics of rotating heat pipes

    Science.gov (United States)

    Daniels, T. C.; Williams, R. J.

    1978-01-01

    Experimental results show conclusively that the presence of a small quantity of a noncondensable gas (NCG) mixed with the working fluid has a considerable effect on the condensation process in a rotating heat pipe. The temperature distribution in the condenser shows the blanketing effect of the NCG and the ratio of the molecular weight of the working fluid to that of the NCG has a very definite effect on the shape of this distribution. Some of the effects are quite similar to the well-established data on stationary heat pipes.

  3. Colloid volume loading does not mitigate decreases in central blood volume during simulated hemorrhage while heat stressed

    DEFF Research Database (Denmark)

    Crandall, Craig G; Wilson, Thad E; Marving, Jens

    2012-01-01

    Heat stress results in profound reductions in the capacity to withstand a simulated hemorrhagic challenge; however, this capacity is normalized if the individual is volume loaded prior to the challenge. The present study tested the hypothesis that volume loading during passive heat stress attenua...

  4. Erosion simulation of first wall beryllium armour under ITER transient heat loads

    Science.gov (United States)

    Bazylev, B.; Janeschitz, G.; Landman, I.; Pestchanyi, S.; Loarte, A.

    2009-04-01

    The beryllium is foreseen as plasma facing armour for the first wall in the ITER in form of Be-clad blanket modules in macrobrush design with brush size about 8-10 cm. In ITER significant heat loads during transient events (TE) are expected at the main chamber wall that may leads to the essential damage of the Be armour. The main mechanisms of metallic target damage remain surface melting and melt motion erosion, which determines the lifetime of the plasma facing components. Melting thresholds and melt layer depth of the Be armour under transient loads are estimated for different temperatures of the bulk Be and different shapes of transient loads. The melt motion damages of Be macrobrush armour caused by the tangential friction force and the Lorentz force are analyzed for bulk Be and different sizes of Be-brushes. The damage of FW under radiative loads arising during mitigated disruptions is numerically simulated.

  5. Phase change based cooling for high burst mode heat loads with temperature regulation above the phase change temperature

    Science.gov (United States)

    The United States of America as represented by the United States Department of Energy

    2009-12-15

    An apparatus and method for transferring thermal energy from a heat load is disclosed. In particular, use of a phase change material and specific flow designs enables cooling with temperature regulation well above the fusion temperature of the phase change material for medium and high heat loads from devices operated intermittently (in burst mode). Exemplary heat loads include burst mode lasers and laser diodes, flight avionics, and high power space instruments. Thermal energy is transferred from the heat load to liquid phase change material from a phase change material reservoir. The liquid phase change material is split into two flows. Thermal energy is transferred from the first flow via a phase change material heat sink. The second flow bypasses the phase change material heat sink and joins with liquid phase change material exiting from the phase change material heat sink. The combined liquid phase change material is returned to the liquid phase change material reservoir. The ratio of bypass flow to flow into the phase change material heat sink can be varied to adjust the temperature of the liquid phase change material returned to the liquid phase change material reservoir. Varying the flowrate and temperature of the liquid phase change material presented to the heat load determines the magnitude of thermal energy transferred from the heat load.

  6. More power and less loads in wind farms. 'Heat and flux'

    Energy Technology Data Exchange (ETDEWEB)

    Corten, G.P.; Schaak, P. [ECN Wind Energy, Petten (Netherlands)

    2004-11-01

    We consider a farm as a single energy extracting body instead of a superposition of individual energy extractors, i.e. wind turbines. As a result we found two new hypotheses called Heat and Flux. Both hypotheses reveal that the classical operation of turbines in a wind farm at the Lanchester-Betz optimum does not lead to maximum farm output. However, when the turbines at the windward side of the farm are operated below their optimum, then the power of the turbines under the lee increases in such a way that the net farm production increases slightly. Next to this production advantage of Heat and Flux operation there is also a loading advantage. The average axial loading of the upwind turbines of a farm is reduced in a 'Heat and Flux'-farm. As a result those turbines generate less turbines so that the fatigue loads of the downwind turbines reduce too. The results were confirmed by in a boundary layer tunnel by means of differential measurements between a 'Heat and Flux'-farm and a classical farm.

  7. Kinetic modeling of divertor heat load fluxes in the Alcator C-Mod and DIII-D tokamaks

    Energy Technology Data Exchange (ETDEWEB)

    Pankin, A. Y. [Tech-X Corporation, Boulder, Colorado 80303 (United States); Rafiq, T.; Kritz, A. H. [Department of Physics, Lehigh University, Bethlehem, Pennsylvania 18015 (United States); Park, G. Y. [National Fusion Research Institute, Daejeon, 305-333 (Korea, Republic of); Chang, C. S.; Ku, S. [Princeton Plasma Physics Laboratory, Princeton, New Jersey 08540 (United States); Brunner, D.; Hughes, J. W.; LaBombard, B.; Terry, J. L. [MIT Plasma Science and Fusion Center, Cambridge, Massachusetts 02139 (United States); Groebner, R. J. [General Atomics, San Diego, California 92121 (United States)

    2015-09-15

    The guiding-center kinetic neoclassical transport code, XGC0 [Chang et al., Phys. Plasmas 11, 2649 (2004)], is used to compute the heat fluxes and the heat-load width in the outer divertor plates of Alcator C-Mod and DIII-D tokamaks. The dependence of the width of heat-load fluxes on neoclassical effects, neutral collisions, and anomalous transport is investigated using the XGC0 code. The XGC0 code includes realistic X-point geometry, a neutral source model, the effects of collisions, and a diffusion model for anomalous transport. It is observed that the width of the XGC0 neoclassical heat-load is approximately inversely proportional to the total plasma current I{sub p.} The scaling of the width of the divertor heat-load with plasma current is examined for an Alcator C-Mod discharge and four DIII-D discharges. The scaling of the divertor heat-load width with plasma current is found to be weaker in the Alcator C-Mod discharge compared to scaling found in the DIII-D discharges. The effect of neutral collisions on the 1/I{sub p} scaling of heat-load width is shown not to be significant. Although inclusion of poloidally uniform anomalous transport results in a deviation from the 1/I{sub p} scaling, the inclusion of the anomalous transport that is driven by ballooning-type instabilities results in recovering the neoclassical 1/I{sub p} scaling. The Bohm or gyro-Bohm scalings of anomalous transport do not strongly affect the dependence of the heat-load width on plasma current. The inclusion of anomalous transport, in general, results in widening the width of neoclassical divertor heat-load and enhances the neoclassical heat-load fluxes on the divertor plates. Understanding heat transport in the tokamak scrape-off layer plasmas is important for strengthening the basis for predicting divertor conditions in ITER.

  8. Online short-term heat load forecasting for single family houses

    DEFF Research Database (Denmark)

    Bacher, Peder; Madsen, Henrik; Nielsen, Henrik Aalborg

    2013-01-01

    This paper presents a method for forecasting the load for heating in a single-family house. Both space and hot tap water heating are forecasted. The forecasting model is built using data from sixteen houses in Sønderborg, Denmark, combined with local climate measurements and weather forecasts....... The models are optimized to fit the level of optimal adaptivity and the thermal dynamical response of the building. Identification of a model, which is suitable for application to all the houses, is carried out. The results show that the forecasting errors mainly are related to: unpredictable high frequency...

  9. New heating load calculation in practice; Neue Heizlastberechnung in der Praxis

    Energy Technology Data Exchange (ETDEWEB)

    Kroeber, C. [REHAU AG und Co., REHAU-Akademie, Erlangen (Germany)

    2004-07-01

    First the heating demand/standard heat load of the building is calculated related to DIN 4701 and than by DIN EN 12831. The topic is to considerate not new formulas and calculation steps but looking on the results of the calculation and discussing it. (GL) [German] Am Beispiel eines Mehrfamilienhauses soll dieser Frage auf den Grund gegangen werden. Dazu wird der Norm-Waermebedarf/die Norm-Heizlast des Gebaeudes zuerst nach DIN 4701 und dann nach DIN EN 12831 berechnet. Dabei liegt der Schwerpunkt der Betrachtung nicht auf den neuen Berechnungsansaetzen und Formeln, sondern vielmehr auf der Betrachtung der Berechnungsergebnisse. (orig.)

  10. Measuring the Heat Load on the Flight ASTRO-H Soft Xray Spectrometer Dewar

    Science.gov (United States)

    DiPirro, M.; Shirron, P.; Yoshida, S.; Kanao, K.; Tsunematsu, S.; Fujimoto, R.; Sneiderman, G.; Kimball, M.; Ezoe, Y.; Ishikawa, K.; Takei, Y.; Mitsuda, K.; Kelley, R.

    2015-01-01

    The Soft Xray Spectrometer (SXS) instrument on-board the ASTRO-H X-ray mission is based on microcalorimeters operating at 50 mK. Low temperature is achieved by use of an adiabatic demagnetization refrigerator (ADR) cyclically operating up to a heat sink at either 1.2 K or 4.5 K. The 1.2 K heat sink is provided by a 40 liter superfluid helium dewar. The parasitic heat to the helium from supports, plumbing, wires, and radiation, and the cyclic heat dumped by the ADR operation determine the liquid helium lifetime. To measure this lifetime we have used various techniques to rapidly achieve thermal equilibrium and then measure the boil-off rate of the helium. We have measured a parasitic heat of 650 microwatts and a cyclic heat of 100 microwatts for a total of 750 microwatts. This closely matches the predicted heat load. Starting with a fill level at launch of more than 33 liters results in a lifetime of greater than 4 years for the liquid helium. The techniques and accuracy for this measurement will be explained in this paper.

  11. Calibration of a silver thin film gauge for short duration convective step heat load

    Indian Academy of Sciences (India)

    SHRUTIDHARA SARMA; NIRANJAN SAHOO; AYNUR UNAL

    2016-07-01

    Thin film gauges (TFGs) are a promising candidate for measuring transient heat fluxes in the applications involving very short duration of heating environment. They are basically resistance temperature detectors (RTDs) having the capability of responding in the range of few microseconds. In the present study, asilver thin film gauge (STFG) is fabricated and calibrated in-house with a view to assess the performance of STFGs in dynamic environment. Convective heat load is supplied by a hot-air gun where the heated air jet strikes the gauge and its response is obtained through voltage signal. Subsequently, the surface heat fluxes are estimated by using one dimensional heat conduction modeling. The similar experimental environment is studied to obtain the flow behavior of hot-air jet emanating into atmosphere by using numerical simulations. The selfsimilar velocities are plotted as well as the interference of outer domain into the experiment parameters has been studied. Ultimately, the surface heat fluxes obtained from various methods are compared to analyse the performance of this hand-made STFG. This study reveals the ability of STFGs to be used in practical short duration transient situations.

  12. An Optimal Control Approach for an Overall Cryogenic Plant Under Pulsed Heat Loads

    CERN Document Server

    Gómez Palacin, Luis; Blanco Viñuela, Enrique; Maekawa, Ryuji; Chalifour, Michel

    2015-01-01

    This work deals with the optimal management of a cryogenic plant composed by parallel refrigeration plants, which provide supercritical helium to pulsed heat loads. First, a data reconciliation approach is proposed to estimate precisely the refrigerator variables necessary to deduce the efficiency of each refrigerator. Second, taking into account these efficiencies, an optimal operation of the system is proposed and studied. Finally, while minimizing the power consumption of the refrigerators, the control system maintains stable operation of the cryoplant under pulsed heat loads. The management of the refrigerators is carried out by an upper control layer, which balances the relative production of cooling power in each refrigerator. In addition, this upper control layer deals with the mitigation of malfunctions and faults in the system. The proposed approach has been validated using a dynamic model of the cryoplant developed with EcosimPro software, based on first principles (mass and energy balances) and the...

  13. Design and implementation of a multiaxial loading capability during heating on an engineering neutron diffractometer

    Energy Technology Data Exchange (ETDEWEB)

    Benafan, O., E-mail: othmane.benafan@nasa.gov [NASA Glenn Research Center, Structures and Materials Division, Cleveland, Ohio 44135 (United States); Advanced Materials Processing and Analysis Center, Materials Science and Engineering Department, University of Central Florida, Orlando, Florida 32816 (United States); Padula, S. A. [NASA Glenn Research Center, Structures and Materials Division, Cleveland, Ohio 44135 (United States); Skorpenske, H. D.; An, K. [Spallation Neutron Source, Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831 (United States); Vaidyanathan, R. [Advanced Materials Processing and Analysis Center, Materials Science and Engineering Department, University of Central Florida, Orlando, Florida 32816 (United States)

    2014-10-01

    A gripping capability was designed, implemented, and tested for in situ neutron diffraction measurements during multiaxial loading and heating on the VULCAN engineering materials diffractometer at the spallation neutron source at Oak Ridge National Laboratory. The proposed capability allowed for the acquisition of neutron spectra during tension, compression, torsion, and/or complex loading paths at elevated temperatures. The design consisted of age-hardened, Inconel{sup ®} 718 grips with direct attachment to the existing MTS load frame having axial and torsional capacities of 100 kN and 400 N·m, respectively. Internal cooling passages were incorporated into the gripping system for fast cooling rates during high temperature experiments up to ~1000 K. The specimen mounting couplers combined a threaded and hexed end-connection for ease of sample installation/removal without introducing any unwanted loads. Instrumentation of this capability is documented in this work along with various performance parameters. The gripping system was utilized to investigate deformation in NiTi shape memory alloys under various loading/control modes (e.g., isothermal, isobaric, and cyclic), and preliminary results are presented. The measurements facilitated the quantification of the texture, internal strain, and phase fraction evolution in NiTi shape memory alloys under various loading/control modes.

  14. Design and implementation of a multiaxial loading capability during heating on an engineering neutron diffractometer

    Science.gov (United States)

    Benafan, O.; Padula, S. A.; Skorpenske, H. D.; An, K.; Vaidyanathan, R.

    2014-10-01

    A gripping capability was designed, implemented, and tested for in situ neutron diffraction measurements during multiaxial loading and heating on the VULCAN engineering materials diffractometer at the spallation neutron source at Oak Ridge National Laboratory. The proposed capability allowed for the acquisition of neutron spectra during tension, compression, torsion, and/or complex loading paths at elevated temperatures. The design consisted of age-hardened, Inconel® 718 grips with direct attachment to the existing MTS load frame having axial and torsional capacities of 100 kN and 400 N.m, respectively. Internal cooling passages were incorporated into the gripping system for fast cooling rates during high temperature experiments up to ˜1000 K. The specimen mounting couplers combined a threaded and hexed end-connection for ease of sample installation/removal without introducing any unwanted loads. Instrumentation of this capability is documented in this work along with various performance parameters. The gripping system was utilized to investigate deformation in NiTi shape memory alloys under various loading/control modes (e.g., isothermal, isobaric, and cyclic), and preliminary results are presented. The measurements facilitated the quantification of the texture, internal strain, and phase fraction evolution in NiTi shape memory alloys under various loading/control modes.

  15. A Large-scale Test Facility for Heat Load Measurements down to 1.9 K

    CERN Document Server

    Dufay, L; Rieubland, Jean Michel; Vandoni, Giovanna

    2002-01-01

    Laboratory-scale tests aimed at minimizing the thermal loads of the LHC magnet cryostat have gone along with the development of the various mechanical components. For final validation of the industrial design with respect to heat inleaks between large surfaces at different temperatures, a full-scale test cryostat has been constructed. The facility reproduces the same pattern of temperature levels as the LHC dipole cryostat, avoiding the heat inleaks from local components like supports and feedthroughs and carefully minimizing fringe effects due to the truncated geometry of the facility with respect to the LHC cryostats serial layout. Thermal loads to the actively cooled radiation screen, operated between 50 K and 65 K, are measured by enthalpy difference along its length. At 1.9 K, the loads are obtained from the temperature difference across a superfluid helium exchanger. On the beam screen, the electrical power needed to stabilize the temperature at 20 K yields a direct reading of the heat losses. Precise i...

  16. Titanium tritide radioisotope heat source development : palladium-coated titanium hydriding kinetics and tritium loading tests.

    Energy Technology Data Exchange (ETDEWEB)

    Van Blarigan, Peter; Shugard, Andrew D.; Walters, R. Tom (Savannah River National Labs, Aiken, SC)

    2012-01-01

    We have found that a 180 nm palladium coating enables titanium to be loaded with hydrogen isotopes without the typical 400-500 C vacuum activation step. The hydriding kinetics of Pd coated Ti can be described by the Mintz-Bloch adherent film model, where the rate of hydrogen absorption is controlled by diffusion through an adherent metal-hydride layer. Hydriding rate constants of Pd coated and vacuum activated Ti were found to be very similar. In addition, deuterium/tritium loading experiments were done on stacks of Pd coated Ti foil in a representative-size radioisotope heat source vessel. The experiments demonstrated that such a vessel could be loaded completely, at temperatures below 300 C, in less than 10 hours, using existing department-of-energy tritium handling infrastructure.

  17. Transient modelling of heat loading of phase change material for energy storage

    Directory of Open Access Journals (Sweden)

    Asyraf W.M.

    2017-01-01

    Full Text Available As the development of solar energy is getting advance from time to time, the concentration solar technology also get the similar attention from the researchers all around the globe. This technology concentrate a large amount of energy into main spot. To collect all the available energy harvest from the solar panel, a thermal energy storage is required to convert the heat energy to one of the purpose such as electrical energy. With the idea of energy storage application that can be narrow down to commercial application such as cooking stove. Using latent heat type energy storage seem to be appropriate with the usage of phase change material (PCM that can release and absorb heat energy at nearly constant temperature by changing its state. Sodium nitrate (NaNO3 and potassium nitrate (KNO3 was selected to use as PCM in this project. This paper focus on the heat loading process and the melting process of the PCM in the energy storage using a computer simulation. The model of the energy storage was created as solid three dimensional modelling using computer aided software and the geometry size of it depend on how much it can apply to boil 1 kg of water in cooking application. The materials used in the tank, heat exchanger and the heat transfer fluid are stainless steel, copper and XCELTHERM MK1, respectively. The analysis was performed using a commercial simulation software in a transient state. The simulation run on different value of velocity but kept controlled under laminar state only, then the relationship of velocity and heat distribution was studied and the melting process of the PCM also has been analyzed. On the effect of heat transfer fluid velocity, the higher the velocity resulted in higher the rate of heat transfer. The comparison between the melting percentages of the PCMs under test conditions show that NaNO3 melts quite faster than KNO3.

  18. Current Status and Performance Tests of Korea Heat Load Test Facility KoHLT-EB

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sukkwon; Jin, Hyunggon; Shin, Kyuin; Choi, Boguen; Lee, Eohwak; Yoon, Jaesung; Lee, Dongwon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Kim, Duckhoi; Cho, Seungyon [National Fusion Research Institute, Daejeon (Korea, Republic of)

    2013-05-15

    A commissioning test has been scheduled to establish the installation and preliminary performance experiments of the copper hypervapotron mockups. And a qualification test will be performed to evaluate the CuCrZr duct liner in the ITER neutral beam injection facility and the ITER first wall small-scale mockups of the semi-prototype, at up to 1.5 and 5 MW/m{sup 2} high heat flux. Also, this system will be used to test other PFCs for ITER and materials for tokamak reactors. Korean high heat flux test facility(KoHLT-EB; Korea Heat Load Test facility - Electron Beam) by using an electron beam system has been constructed in KAERI to perform the qualification test for ITER blanket FW semi-prototype mockups, hypervapotron cooling devices in fusion devices, and other ITER plasma facing components. The commissioning and performance tests with the supplier of e-gun system have been performed on November 2012. The high heat flux test for hypervapotron cooling device and calorimetry were performed to measure the surface heat flux, the temperature profile and cooling performance. Korean high heat flux test facility for the plasma facing components of nuclear fusion machines will be constructed to evaluate the performance of each component. This facility for the plasma facing materials will be equipped with an electron beam system with a 60 kV acceleration gun.

  19. Oligonol Supplementation Affects Leukocyte and Immune Cell Counts after Heat Loading in Humans

    Directory of Open Access Journals (Sweden)

    Jeong Beom Lee

    2014-06-01

    Full Text Available Oligonol is a low-molecular-weight form of polyphenol and has antioxidant and anti-inflammatory activity, making it a potential promoter of immunity. This study investigates the effects of oligonol supplementation on leukocyte and immune cell counts after heat loading in 19 healthy male volunteers. The participants took a daily dose of 200 mg oligonol or a placebo for 1 week. After a 2-week washout period, the subjects were switched to the other study arm. After each supplement, half-body immersion into hot water was made, and blood was collected. Then, complete and differential blood counts were performed. Flow cytometry was used to enumerate and phenotype lymphocyte subsets. Serum concentrations of interleukin (IL-1β and IL-6 in blood samples were analyzed. Lymphocyte subpopulation variables included counts of total T cells, B cells, and natural killer (NK cells. Oligonol intake attenuated elevations in IL-1β (an 11.1-fold change vs. a 13.9-fold change immediately after heating; a 12.0-fold change vs. a 12.6-fold change 1h after heating and IL-6 (an 8.6-fold change vs. a 9.9-fold change immediately after heating; a 9.1-fold change vs. a 10.5-fold change 1h after heating immediately and 1 h after heating in comparison to those in the placebo group. Oligonol supplementation led to significantly higher numbers of leukocytes (a 30.0% change vs. a 21.5% change immediately after heating; a 13.5% change vs. a 3.5% change 1h after heating and lymphocytes (a 47.3% change vs. a 39.3% change immediately after heating; a 19.08% change vs. a 2.1% change 1h after heating relative to those in the placebo group. Oligonol intake led to larger increases in T cells, B cells, and NK cells at rest (p < 0.05, p < 0.05, and p < 0.001, respectively and immediately after heating (p < 0.001 in comparison to those in the placebo group. In addition, levels of T cells (p < 0.001 and B cells (p < 0.001 were significantly higher 1 h after heating in comparison to those in

  20. Initiation of Heated PBX-9501 Explosive When Exposed to Dynamic Loading

    Energy Technology Data Exchange (ETDEWEB)

    Urtiew, P A; Vandersall, K S; Tarver, C M; Garcia, F

    2005-08-16

    Shock initiation experiments on the heated PBX9501 explosive (95% HMX, 2.5% estane, and 2.5% nitro-plasticizer by weight) were performed at temperatures 150 C and 180 C to obtain in-situ pressure gauge data. A 101 mm diameter propellant driven gas gun was utilized to initiate the PBX9501 explosive and manganin piezo-resistive pressure gauge packages were placed between sample slices to measure time resolved local pressure histories. The run-distance-to-detonation points on the Pop-plot for these experiments showed the sensitivity of the heated material to shock loading. This work shows that heated PBX-9501 is more shock sensitive than it is at ambient conditions. Proper Ignition and Growth modeling parameters were obtained to fit the experimental data. This parameter set will allow accurate code predictions to be calculated for safety scenarios involving PBX9501 explosives at temperatures close to those at which experiments were performed.

  1. Using Simulink Simulation to Evaluate Load Following Characteristics of SOFC Generator with Heat Exchanger Considering Heat Balance

    Science.gov (United States)

    Tuyen, Nguyen Duc; Fujita, Goro; Yokoyama, Ryuichi; Koyanagi, Kaoru; Funabashi, Toshihisa; Nomura, Masakatsu

    That ever increasing electricity consumption, progress in power deregulation, and rising public awareness for environment have created more interest in fuel cell distributed generation. Among different types of fuel cells, solid oxide fuel cells (SOFCs) manifest themselves as great potential applications due to many advantages such as low emission, high efficiency, and high power rating. On the other hand, SOFC systems are beneficial because they can convert fuel such as natural gas (almost CH4) which is supplied by widespread systems in many countries into electricity efficiently using internal reforming. In facts, the load demand changes flexibly and fuel cell life time decreases by rapid thermal change. Its lifetime may be extended by maintaining in appropriate temperature. Therefore, it is important to acquire the load following performance as well as control of operation temperature. This paper addresses components of the simple SOFC power unit model with heat exchanger (HX) included. Typical dynamical submodels are used to follow the variation of load demand at a local location that considers temperature characteristics using the Matlab-SIMULINK program.

  2. Development of a laser-based heating system for in situ synchrotron-based X-ray tomographic microscopy.

    Science.gov (United States)

    Fife, Julie L; Rappaz, Michel; Pistone, Mattia; Celcer, Tine; Mikuljan, Gordan; Stampanoni, Marco

    2012-05-01

    Understanding the formation of materials at elevated temperatures is critical for determining their final properties. Synchrotron-based X-ray tomographic microscopy is an ideal technique for studying such processes because high spatial and temporal resolutions are easily achieved and the technique is non-destructive, meaning additional analyses can take place after data collection. To exploit the state-of-the-art capabilities at the tomographic microscopy and coherent radiology experiments (TOMCAT) beamline of the Swiss Light Source, a general-use moderate-to-high-temperature furnace has been developed. Powered by two diode lasers, it provides controlled localized heating, from 673 to 1973 K, to examine many materials systems and their dynamics in real time. The system can also be operated in various thermal modalities. For example, near-isothermal conditions at a given sample location can be achieved with a prescribed time-dependent temperature. This mode is typically used to study isothermal phase transformations; for example, the formation of equiaxed grains in metallic systems or to nucleate and grow bubble foams in silicate melts under conditions that simulate volcanic processes. In another mode, the power of the laser can be fixed and the specimen moved at a constant speed in a user-defined thermal gradient. This is similar to Bridgman solidification, where the thermal gradient and cooling rate control the microstructure formation. This paper details the experimental set-up and provides multiple proofs-of-concept that illustrate the versatility of using this laser-based heating system to explore, in situ, many elevated-temperature phenomena in a variety of materials.

  3. Influence of the heater material on the critical heat load at boiling of liquids on surfaces with different sizes

    Science.gov (United States)

    Anokhina, E. V.

    2010-05-01

    Data on critical heat loads q cr for the saturated and unsaturated pool boiling of water and ethanol under atmospheric pressure are reported. It is found experimentally that the critical heat load does not necessarily coincide with the heat load causing burnout of the heater, which should be taken into account. The absolute values of q cr for the boiling of water and ethanol on copper surfaces 65, 80, 100, 120, and 200 μm in diameter; tungsten surface 100 μm in diameter; and nichrome surface 100 μm in diameter are obtained experimentally.

  4. Tungsten joining with copper alloy and its high heat load performance

    Science.gov (United States)

    Liu, Xiang; Lian, Youyun; Chen, Lei; Cheng, Zengkui; Chen, Jiming; Duan, Xuru; Song, Jioupeng; Yu, Yang

    2014-12-01

    W-CuCrZr joining technology by using low activation Cu-Mn filler metal was developed at Southwestern Institute of Physics (SWIP) for the manufacturing of divertor components of fusion experiment devices. In addition, a fast W coating technology by chemical vapor deposition (CVD) was also developed and CVD-W/CuCrZr and CVD-W/C mockups with a W coating thickness of 2 mm were prepared. In order to assess their high heat flux (HHF) performances, a 60 kW Electron-beam Material testing Scenario (EMS-60) equipped with a 150 keV electron beam welding gun was constructed at SWIP. Experimental results indicated that brazed W/CuCrZr mockups can withstand 8 MW/m2 heat flux for 1000 cycles without visible damages and CVD-W/CuCrZr mockups with W-Cu gradient interface can survive 1000 cycles under 11 MW/m2 heat flux. An ultrasonic inspection method for non-destructive tests (NDT) of brazed W/CuCrZr mockups was established and 2 mm defect can be detected. Infinite element analysis and heat load tests indicated that 5 mm defect had less noticeable influence on the heat transfer.

  5. Risk Assessment of Heating, Ventilating, and Air-Conditioning Strategies in Low-Load Homes

    Energy Technology Data Exchange (ETDEWEB)

    Poerschke, Andrew [IBACOS, Inc., Pittsburgh, PA (United States)

    2016-02-17

    "Modern, energy efficient homes conforming to the Zero Energy Ready Home standard face the challenge of meeting high customer expectations for comfort. Traditional heating, ventilation, and air conditioning (HVAC) sizing and control strategies may be insufficient to adequately condition each zone due to unique load patterns in each room caused by a number of factors. These factors include solar heat gains, occupant-related gains, and gains associated with appliances and electronics. Because of shrinking shell loads, these intermittent factors are having an increasingly significant impact on the thermal load in each zone. Consequently, occupant comfort can be compromised. To evaluate the impact of climate and house geometry, as well as HVAC system and control strategies on comfort conditions, IBACOS analyzed the results of 99 TRNSYS multiple-zone simulations. The results of this analysis indicate that for simple-geometry and single-story plans, a single zone and thermostat can adequately condition the entire house. Demanding house geometry and houses with multiple stories require the consideration of multiple thermostats and multiple zones.

  6. Blast load estimation using Finite Volume Method and linear heat transfer

    Directory of Open Access Journals (Sweden)

    Lidner Michał

    2016-01-01

    Full Text Available From the point of view of people and building security one of the main destroying factor is the blast load. Rational estimating of its results should be preceded with knowledge of complex wave field distribution in time and space. As a result one can estimate the blast load distribution in time. In considered conditions, the values of blast load are estimating using the empirical functions of overpressure distribution in time (Δp(t. The Δp(t functions are monotonic and are the approximation of reality. The distributions of these functions are often linearized due to simplifying of estimating the blast reaction of elements. The article presents a method of numerical analysis of the phenomenon of the air shock wave propagation. The main scope of this paper is getting the ability to make more realistic the Δp(t functions. An explicit own solution using Finite Volume Method was used. This method considers changes in energy due to heat transfer with conservation of linear heat transfer. For validation, the results of numerical analysis were compared with the literature reports. Values of impulse, pressure, and its duration were studied.

  7. Recrystallization and grain growth induced by ELMs-like transient heat loads in deformed tungsten samples.

    Science.gov (United States)

    Suslova, A; El-Atwani, O; Sagapuram, D; Harilal, S S; Hassanein, A

    2014-11-04

    Tungsten has been chosen as the main candidate for plasma facing components (PFCs) due to its superior properties under extreme operating conditions in future nuclear fusion reactors such as ITER. One of the serious issues for PFCs is the high heat load during transient events such as ELMs and disruption in the reactor. Recrystallization and grain size growth in PFC materials caused by transients are undesirable changes in the material, since the isotropic microstructure developed after recrystallization exhibits a higher ductile-to-brittle transition temperature which increases with the grain size, a lower thermal shock fatigue resistance, a lower mechanical strength, and an increased surface roughening. The current work was focused on careful determination of the threshold parameters for surface recrystallization, grain growth rate, and thermal shock fatigue resistance under ELM-like transient heat events. Transient heat loads were simulated using long pulse laser beams for two different grades of ultrafine-grained tungsten. It was observed that cold rolled tungsten demonstrated better power handling capabilities and higher thermal stress fatigue resistance compared to severely deformed tungsten. Higher recrystallization threshold, slower grain growth, and lower degree of surface roughening were observed in the cold rolled tungsten.

  8. Modelling reduction of urban heat load in Vienna by modifying surface properties of roofs

    Science.gov (United States)

    Žuvela-Aloise, Maja; Andre, Konrad; Schwaiger, Hannes; Bird, David Neil; Gallaun, Heinz

    2017-01-01

    The study examines the potential of urban roofs to reduce the urban heat island (UHI) effect by changing their reflectivity and implementing vegetation (green roofs) using the example of the City of Vienna. The urban modelling simulations are performed based on high-resolution orography and land use data, climatological observations, surface albedo values from satellite imagery and registry of the green roof potential in Vienna. The modelling results show that a moderate increase in reflectivity of roofs (up to 0.45) reduces the mean summer temperatures in the densely built-up environment by approximately 0.25 °C. Applying high reflectivity materials (roof albedo up to 0.7) leads to average cooling in densely built-up area of approximately 0.5 °C. The green roofs yield a heat load reduction in similar order of magnitude as the high reflectivity materials. However, only 45 % of roof area in Vienna is suitable for greening and the green roof potential mostly applies to industrial areas in city outskirts and is therefore not sufficient for substantial reduction of the UHI effect, particularly in the city centre which has the highest heat load. The strongest cooling effect can be achieved by combining the green roofs with high reflectivity materials. In this case, using 50 or 100 % of the green roof potential and applying high reflectivity materials on the remaining surfaces have a similar cooling effect.

  9. Behavior of Brazed W/Cu Mockup Under High Heat Flux Loads

    Science.gov (United States)

    Chen, Lei; Lian, Youyun; Liu, Xiang

    2014-03-01

    In order to transfer the heat from the armor to the coolant, tungsten has to be connected with a copper heat sink. The joint technology is the most critical issue for manufacturing plasma facing components. Consequently, the reliability of the joints should be verified by a great number of high-heat-flux (HHF) tests to simulate the real load conditions. W/Cu brazed joint technology with sliver free filler metal CuMnNi has been developed at Southwestern Institute of Physics (SWIP). Screening and thermal fatigue tests of one small-scale flat tile W/CuCrZr mockup were performed on a 60 kW electron-beam Material testing scenario (EMS-60) constructed recently at SWIP. The module successfully survived screening test with the absorbed power density (Pabs) of 2 MW/m2 to 10 MW/m2 and the following 1000 cycles at Pabs of 7.2 MW/m2 without hot spots and overheating zones during the whole test campaign. Metallurgy and SEM observations did not find any cracks at both sides and the interface, indicating a good bonding of W and CuCrZr alloy. In addition, finite element simulations by ANSYS 12.0 under experimental load conditions were performed and compared with experimental results.

  10. Time-resolved soft X-ray core-level photoemission spectroscopy at 880 °C using the pulsed laser and synchrotron radiation and the pulse heating current

    Science.gov (United States)

    Abukawa, T.; Yamamoto, S.; Yukawa, R.; Kanzaki, S.; Mukojima, K.; Matsuda, I.

    2017-02-01

    We developed a time-resolved photoemission spectroscopy system for tracking the temporal variation in an electronic state of a heated sample. Our pump-probe method used laser and synchrotron radiation pulses on a silicon surface that was heated by a synchronized pulse current that did not interfere with the measurements. The transient surface photovoltage effect on the Si 2p core spectra was measured from room temperature to 880 °C and was found to be consistent with the thermal carrier distributions in silicon crystals at the corresponding temperatures. This versatile technique may have applications studying molecular dynamics on high temperature surfaces such as in catalytic reactions.

  11. Impact of Groundwater Flow and Energy Load on Multiple Borehole Heat Exchangers.

    Science.gov (United States)

    Dehkordi, S Emad; Schincariol, Robert A; Olofsson, Bo

    2015-01-01

    The effect of array configuration, that is, number, layout, and spacing, on the performance of multiple borehole heat exchangers (BHEs) is generally known under the assumption of fully conductive transport. The effect of groundwater flow on BHE performance is also well established, but most commonly for single BHEs. In multiple-BHE systems the effect of groundwater advection can be more complicated due to the induced thermal interference between the boreholes. To ascertain the influence of groundwater flow and borehole arrangement, this study investigates single- and multi-BHE systems of various configurations. Moreover, the influence of energy load balance is also examined. The results from corresponding cases with and without groundwater flow as well as balanced and unbalanced energy loads are cross-compared. The groundwater flux value, 10(-7) m/s, is chosen based on the findings of previous studies on groundwater flow interaction with BHEs and thermal response tests. It is observed that multi-BHE systems with balanced loads are less sensitive to array configuration attributes and groundwater flow, in the long-term. Conversely, multi-BHE systems with unbalanced loads are influenced by borehole array configuration as well as groundwater flow; these effects become more pronounced with time, unlike when the load is balanced. Groundwater flow has more influence on stabilizing loop temperatures, compared to array characteristics. Although borehole thermal energy storage (BTES) systems have a balanced energy load function, preliminary investigation on their efficiency shows a negative impact by groundwater which is due to their dependency on high temperature gradients between the boreholes and surroundings.

  12. USE OF GAS BURNERS TYPE "DAVA" OPERATING UNDER VARIABLE LOAD TO PRODUCE HEAT AND HOT WATER

    Directory of Open Access Journals (Sweden)

    Daud V.

    2014-12-01

    Full Text Available The article brings additional information referred to upgraded gas burners type "DAVA", which are characterized by high performance at variable load. Adaptation of burner operation is carried out automatically. There are presented design features that allow increase of the efficiency and the reliability of these burners at variable load, and reducing natural gas consumption. The range of variation of the coefficient of excess air affects the efficiency of the burner. The experimental results of the tests of gas burners of different power had confirmed the economic effect of the upgraded burners at heat production. It is proved that economic effect increases with increasing of burner output and of operation time during the season.

  13. Simulation of CO2 Brayton Cycle for Engine Exhaust Heat Recovery under Various Operating Loads

    Institute of Scientific and Technical Information of China (English)

    舒歌群; 张承宇; 田华; 高媛媛; 李团兵; 仇荣赓

    2015-01-01

    A bottoming cycle system based on CO2 Brayton cycle is proposed to recover the engine exhaust heat. Its performance is compared with the conventional air Brayton cycle under five typical engine conditions. The results show that CO2 Brayton cycle proves to be superior to the air Brayton cycle in terms of the system net output power, thermal efficiency and recovery efficiency. In most cases, the recovery efficiency of CO2 Brayton cycle can be higher than 9%and the system has a better performance at the engine’s high operating load. The thermal efficiency can be as large as 24.83%under 100%operating load, accordingly, the net output power of 14.86 kW is obtained.

  14. Heat load and deuterium plasma effects on SPS and WSP tungsten

    Directory of Open Access Journals (Sweden)

    Vilémová Monika

    2015-06-01

    Full Text Available Tungsten is a prime choice for armor material in future nuclear fusion devices. For the realization of fusion, it is necessary to address issues related to the plasma–armor interactions. In this work, several types of tungsten material were studied, i.e. tungsten prepared by spark plasma sintering (SPS and by water stabilized plasma spraying (WSP technique. An intended surface porosity was created in the samples to model hydrogen/helium bubbles. The samples were subjected to a laser heat loading and a radiation loading of deuterium plasma to simulate edge plasma conditions of a nuclear fusion device (power density of 108 W/cm2 and 107 W/cm2, respectively, in the pulse intervals up to 200 ns. Thermally induced changes in the morphology and the damage to the studied surfaces are described. Possible consequences for the fusion device operation are pointed out.

  15. Investigation of damages induced by ITER-relevant heat loads during massive gas injections on Beryllium

    Directory of Open Access Journals (Sweden)

    B. Spilker

    2016-12-01

    Full Text Available Massive gas injections (MGIs will be used in ITER to mitigate the strong damaging effect of full performance plasma disruptions on the plasma facing components. The MGI method transforms the stored plasma energy to radiation that is spread across the vacuum vessel with poloidal and toroidal asymmetries. This work investigated the impact of MGI like heat loading on the first wall armor material beryllium. ITER-relevant power densities of 90-260MWm−2in combination with pulse durations of 5-10ms were exerted onto the S-65 grade beryllium specimens in the electron beam facility JUDITH 1. All tested loading conditions led to noticeable surface morphology changes and in the expected worst case scenario, a crater with thermally induced cracks with a depth of up to ∼340µm formed in the loaded area. The level of destruction in the loaded area was strongly dependent on the pulse number but also on the formation of beryllium oxide. The cyclic melting of beryllium could lead to an armor thinning mechanism under the presence of melt motion driving forces such as surface tension, magnetic forces, and plasma pressure.

  16. Volume loading augments cutaneous vasodilatation and cardiac output of heat stressed older adults.

    Science.gov (United States)

    Gagnon, Daniel; Romero, Steven A; Ngo, Hai; Sarma, Satyam; Cornwell, William K; Poh, Paula Y S; Stoller, Douglas; Levine, Benjamin D; Crandall, Craig G

    2017-08-21

    Age-related changes in cutaneous microvascular and cardiac functions limit the extent of cutaneous vasodilatation and the increase in cardiac output that healthy older adults can achieve during passive heat stress. However, it is unclear if these age-related changes in microvascular and cardiac functions maximally restrain the levels of cutaneous vasodilatation and cardiac output that healthy older adults can achieve during heat stress. We observed that rapid volume loading, performed during passive heat stress, augments both cutaneous vasodilatation and cardiac output in healthy older humans. These findings demonstrate that the microcirculation of healthy aged skin can further dilate during passive heat exposure, despite peripheral limitations to vasodilatation. Furthermore, healthy older humans can augment cardiac output when cardiac pre-load is increased during heat stress. Primary ageing markedly attenuates cutaneous vasodilatation and the increase in cardiac output during passive heating. However, it remains unclear if these responses are maximally restrained by age-related changes in cutaneous microvascular and cardiac functions. We hypothesized that rapid volume loading performed during heat stress would increase cardiac output in older adults without parallel increases in cutaneous vasodilatation. Twelve young (Y: 26 ± 5 years) and ten older (O: 69 ± 3 years) healthy adults were passively heated until core temperature increased by 1.5°C. Cardiac output (thermodilution), forearm vascular conductance (FVC, venous occlusion plethysmography) and cutaneous vascular conductance (CVC, laser-Doppler) were measured before and after rapid infusion of warmed saline (15 mL kg(-1) , ∼7 min). While heat stressed, but prior to saline infusion, cardiac output (O: 6.8 ± 0.4 vs. Y: 9.4 ± 0.6 L min(-1) ), FVC (O: 0.08 ± 0.01 vs. Y: 0.17 ± 0.02 mL (100 mL min(-1)  mmHg(-1) )(-1) ), and CVC (O: 1.29 ± 0.34 vs. Y: 1.93 ± 0.30

  17. Optimal control of a fuel cell/wind/PV/grid hybrid system with thermal heat pump load

    CSIR Research Space (South Africa)

    Sichilalu, S

    2016-10-01

    Full Text Available This paper presents an optimal energy management strategy for a grid-tied photovoltaic–wind-fuel cell hybrid power supply system. The hybrid system meets the load demand consisting of an electrical load and a heat pump water heater supplying thermal...

  18. Temperature calculations of heat loads in rotating target wheels exposed to high beam currents.

    Energy Technology Data Exchange (ETDEWEB)

    Greene, J. P.; Gabor, R.; Neubauer, J.

    2000-11-29

    In heavy-ion physics, high beam currents can eventually melt or destroy the target. Tightly focused beams on stationary targets of modest melting point will exhibit short lifetimes. Defocused or wobbled beams are employed to enhance target survival. Rotating targets using large diameter wheels can help overcome target melting and allow for higher beam currents to be used in experiments. The purpose of the calculations in this work is to try and predict the safe maximum beam currents which produce heat loads below the melting point of the target material.

  19. Simultaneous optimization of the cavity heat load and trip rates in linacs using a genetic algorithm

    Directory of Open Access Journals (Sweden)

    Balša Terzić

    2014-10-01

    Full Text Available In this paper, a genetic algorithm-based optimization is used to simultaneously minimize two competing objectives guiding the operation of the Jefferson Lab’s Continuous Electron Beam Accelerator Facility linacs: cavity heat load and radio frequency cavity trip rates. The results represent a significant improvement to the standard linac energy management tool and thereby could lead to a more efficient Continuous Electron Beam Accelerator Facility configuration. This study also serves as a proof of principle of how a genetic algorithm can be used for optimizing other linac-based machines.

  20. Inner cladding influence on large mode area photonic crystal fiber properties under severe heat load

    Science.gov (United States)

    Coscelli, Enrico; Poli, Federica; Dauliat, Romain; Darwich, Dia; Cucinotta, Annamaria; Selleri, Stefano; Schuster, Kay; Benoît, Aurélien; Jamier, Raphael; Roy, Philippe

    2016-03-01

    Constant innovations of fiber technology over the last twenty years has fueled a huge improvement of the performances of fiber lasers. Further power scaling of fiber lasers is currently hindered by the phenomenon of transverse mode instabilities, a sudden deterioration of output beam quality occurring beyond a certain power threshold due to energy transfer from the fiber fundamental mode to high-order modes. Several studies have pinpointed a thermal origin for this phenomenon. A possible solution is to implement fiber designs capable of providing a robust single-mode operation even under severe heat load, in order to prevent such coupling. In this paper the effects on the propagating modes of the change of the inner cladding size and microstructuration in double-cladding photonic crystal fibers under heating condition are discussed, and related to field confinement and single-mode regime.

  1. Analysis of Unsteady Tip and Endwall Heat Transfer in a Highly Loaded Transonic Turbine Stage

    Science.gov (United States)

    Shyam, Vikram; Ameri, Ali; Chen, Jen-Ping

    2010-01-01

    In a previous study, vane-rotor shock interactions and heat transfer on the rotor blade of a highly loaded transonic turbine stage were simulated. The geometry consists of a high pressure turbine vane and downstream rotor blade. This study focuses on the physics of flow and heat transfer in the rotor tip, casing and hub regions. The simulation was performed using the Unsteady Reynolds-Averaged Navier-Stokes (URANS) code MSU-TURBO. A low Reynolds number k-epsilon model was utilized to model turbulence. The rotor blade in question has a tip gap height of 2.1 percent of the blade height. The Reynolds number of the flow is approximately 3x10(exp 6) per meter. Unsteadiness was observed at the tip surface that results in intermittent "hot spots". It is demonstrated that unsteadiness in the tip gap is governed by inviscid effects due to high speed flow and is not strongly dependent on pressure ratio across the tip gap contrary to published observations that have primarily dealt with subsonic tip flows. The high relative Mach numbers in the tip gap lead to a choking of the leakage flow that translates to a relative attenuation of losses at higher loading. The efficacy of new tip geometry is discussed to minimize heat flux at the tip while maintaining choked conditions. In addition, an explanation is provided that shows the mechanism behind the rise in stagnation temperature on the casing to values above the absolute total temperature at the inlet. It is concluded that even in steady mode, work transfer to the near tip fluid occurs due to relative shearing by the casing. This is believed to be the first such explanation of the work transfer phenomenon in the open literature. The difference in pattern between steady and time-averaged heat flux at the hub is also explained.

  2. Experimental validation of advanced regulations for superconducting magnet cooling undergoing periodic heat loads

    Science.gov (United States)

    Lagier, B.; Rousset, B.; Hoa, C.; Bonnay, P.

    2014-01-01

    Superconducting magnets used in tokamaks undergo periodic heat load caused by cycling plasma operations inducing AC losses, neutrons fluxes and eddy currents in magnet structures. In the cryogenic system of JT60-SA tokamak, the Auxiliary Cold Box (ACB) distributes helium from the refrigerator to the cryogenic users and in particular to the superconducting magnets. ACB comprises a saturated helium bath with immersed heat exchangers, extracting heat from independent cooling loops. The supercritical helium flow in each cooling loop is driven by a cold circulator. In order to safely operate the refrigerator during plasma pulses, the interface between the ACB and the refrigerator shall be as stable as possible, with well-balanced bath inlet and outlet mass flows during cycling operation. The solution presented in this paper relies on a combination of regulations to smooth pulsed heat loads and to keep a constant refrigeration power during all the cycle. Two smoothing strategies are presented, both regulating the outlet mass flow of the bath: the first one using the bath as a thermal buffer and the second one storing energy in the loop by varying the cold circulator speed. The bath outlet mass flow is also controlled by an immersed resistive heater which enables a constant evaporation rate in the bath when power coming from the loops is decreasing. The refrigeration power is controlled so that the compensating power remains within an acceptable margin. Experimental validation is achieved using the HELIOS facility. This facility running at CEA Grenoble since 2010 is a scaled down model of the ACB bath and Central Solenoid magnet cooling loop of the JT60-SA tokamak. Test results show performances and robustness of the regulations.

  3. Experimental validation of advanced regulations for superconducting magnet cooling undergoing periodic heat loads

    Energy Technology Data Exchange (ETDEWEB)

    Lagier, B.; Rousset, B.; Hoa, C.; Bonnay, P. [CEA Grenoble INAC/SBT, 17 rue des Martyrs, 38054 Grenoble Cedex 9 (France)

    2014-01-29

    Superconducting magnets used in tokamaks undergo periodic heat load caused by cycling plasma operations inducing AC losses, neutrons fluxes and eddy currents in magnet structures. In the cryogenic system of JT60-SA tokamak, the Auxiliary Cold Box (ACB) distributes helium from the refrigerator to the cryogenic users and in particular to the superconducting magnets. ACB comprises a saturated helium bath with immersed heat exchangers, extracting heat from independent cooling loops. The supercritical helium flow in each cooling loop is driven by a cold circulator. In order to safely operate the refrigerator during plasma pulses, the interface between the ACB and the refrigerator shall be as stable as possible, with well-balanced bath inlet and outlet mass flows during cycling operation. The solution presented in this paper relies on a combination of regulations to smooth pulsed heat loads and to keep a constant refrigeration power during all the cycle. Two smoothing strategies are presented, both regulating the outlet mass flow of the bath: the first one using the bath as a thermal buffer and the second one storing energy in the loop by varying the cold circulator speed. The bath outlet mass flow is also controlled by an immersed resistive heater which enables a constant evaporation rate in the bath when power coming from the loops is decreasing. The refrigeration power is controlled so that the compensating power remains within an acceptable margin. Experimental validation is achieved using the HELIOS facility. This facility running at CEA Grenoble since 2010 is a scaled down model of the ACB bath and Central Solenoid magnet cooling loop of the JT60-SA tokamak. Test results show performances and robustness of the regulations.

  4. Modeling of limiter heat loads and impurity transport in Wendelstein 7-X startup plasmas

    Science.gov (United States)

    Effenberg, Florian; Feng, Y.; Frerichs, H.; Schmitz, O.; Hoelbe, H.; Koenig, R.; Krychowiak, M.; Pedersen, T. S.; Bozhenkov, S.; Reiter, D.

    2015-11-01

    The quasi-isodynamic stellarator Wendelstein 7-X starts plasma operation in a limiter configuration. The field consists of closed magnetic flux surfaces avoiding magnetic islands in the plasma boundary. Because of the small size of the limiters and the absence of wall-protecting elements in this phase, limiter heat loads and impurity generation due to plasma surface interaction become a concern. These issues are studied with the 3D fluid plasma edge and kinetic neutral transport code EMC3-Eirene. It is shown that the 3D SOL consists of three separate helical magnetic flux bundles of different field line connection lengths. A density scan at input power of 4MW reveals a strong modulation of the plasma paramters with the connection length. The limiter peak heat fluxes drop from 14 MWm-2 down to 10 MWm-2 with raising the density from 1 ×1018m-3 to 1.9 ×1019m-3, accompanied by an increase of the heat flux channel widths λq. Radiative power losses can help to avoid thermal overloads of the limiters at the upper margin of the heating power. The power removal feasibility of the intrinsic carbon and other extrinsic light impurities via active gas injection is discussed as a preparation of this method for island divertor operation. Work supported in part by start up funds of the Department of Engineering Physics at the University of Wisconsin - Madison, USA and by the U.S. Department of Energy under grant DE-SC0013911.

  5. Heat load behaviors of plasma sprayed tungsten coatings on copper alloys with different compliant layers

    Energy Technology Data Exchange (ETDEWEB)

    Chong, F.L. [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China)], E-mail: flch@ipp.ac.cn; Chen, J.L.; Li, J.G. [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Hu, D.Y.; Zheng, X.B. [Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai 200051 (China)

    2008-04-15

    Plasma sprayed tungsten (PS-W) coatings with the compliant layers of titanium (Ti), nickel-chromium-aluminum (NiCrAl) alloys and W/Cu mixtures were fabricated on copper alloys, and their properties of the porosity, oxygen content, thermal conductivity and bonding strength were measured. High heat flux tests of actively cooled W coatings were performed by means of an electron beam facility. The results indicated that APS-W coating showed a poorer heat transfer capability and thermo-mechanical properties than VPS-W coating, and the compliant layers improved W coating performance under the heat flux load. Among three compliant layers, W/Cu was the preferable because of its better effects on heat removal and stress alleviating. The optimization of W/Cu compliant layer found that 0.1 mm and 25 vol.%W was optimum compliant layer structure for 1 mm W coating, which induced a 23% reduction of the maximum stress compared to the sharp interface, and the plastic strain was reduced to 0.01% from 1.55%.

  6. Heat load behaviors of plasma sprayed tungsten coatings on copper alloys with different compliant layers

    Science.gov (United States)

    Chong, F. L.; Chen, J. L.; Li, J. G.; Hu, D. Y.; Zheng, X. B.

    2008-04-01

    Plasma sprayed tungsten (PS-W) coatings with the compliant layers of titanium (Ti), nickel-chromium-aluminum (NiCrAl) alloys and W/Cu mixtures were fabricated on copper alloys, and their properties of the porosity, oxygen content, thermal conductivity and bonding strength were measured. High heat flux tests of actively cooled W coatings were performed by means of an electron beam facility. The results indicated that APS-W coating showed a poorer heat transfer capability and thermo-mechanical properties than VPS-W coating, and the compliant layers improved W coating performance under the heat flux load. Among three compliant layers, W/Cu was the preferable because of its better effects on heat removal and stress alleviating. The optimization of W/Cu compliant layer found that 0.1 mm and 25 vol.%W was optimum compliant layer structure for 1 mm W coating, which induced a 23% reduction of the maximum stress compared to the sharp interface, and the plastic strain was reduced to 0.01% from 1.55%.

  7. Changes in heat load profile of typical Danish multi-storey buildings when energy-renovated and supplied with low-temperature district heating

    DEFF Research Database (Denmark)

    Harrestrup, Maria; Svendsen, Svend

    2013-01-01

    end-use savings are implemented in buildings concurrent with the application of low-temperature district heating (LTDH), the heat profiles of the buildings will change. Reducing peak loads is important, since this is the dimensioning foundation for future district heating systems. To avoid oversized...... RE-based capacity, a long-term perspective needs to be taken. Applying LTDH in existing buildings without changing the heating system implies reduced radiator performance, so it is of great importance that acceptable comfort temperatures can still be provided. The results indicate that it is possible...

  8. Kinetic modeling of divertor heat load fluxes in the Alcator C-Mod and DIII-D tokamaks

    CERN Document Server

    Pankin, A Y; Kritz, A H; Park, G Y; Chang, C S; Brunner, D; Groebner, R J; Hughes, J W; LaBombard, B; Terry, J L; Ku, S

    2015-01-01

    The guiding-center kinetic neoclassical transport code, XGC0, [C.S. Chang et. al, Phys. Plasmas 11, 2649 (2004)] is used to compute the heat fluxes and the heat-load width in the outer divertor plates of Alcator C-Mod and DIII-D tokamaks. The dependence of the width of heat-load fluxes on neoclassical effects, neutral collisions and anomalous transport is investigated using the XGC0 code. The XGC0 code includes realistic X-point geometry, a neutral source model, the effects of collisions, and a diffusion model for anomalous transport. It is observed that width of the XGC0 neoclassical heat-load is approximately inversely proportional to the total plasma current $I_{\\rm p}$. The scaling of the width of the divertor heat-load with plasma current is examined for an Alcator C-Mod discharge and four DIII-D discharges. The scaling of the divertor heat-load width with plasma current is found to be weaker in the Alcator C-Mod discharge compared to scaling found in the DIII-D discharges. The effect of neutral collisio...

  9. Heat Load Measurements on a Large Superconducting Magnet An Application of a Void Fraction Meter

    CERN Document Server

    Pengo, R; Junker, S; Passardi, Giorgio; ten Kate, H H J

    2004-01-01

    ATLAS is one of the two major experiments of the LHC project at CERN using cryogenics. The superconducting magnet system of ATLAS is composed of the Barrel Toroid (BT), two End Caps Toroids and the Central Solenoid. The BT is formed of 8 race-track superconducting dipoles, each one 25 m long and 5 m wide. A reduced scale prototype (named B0) of one of the 8 dipoles, about one third of the length, has been constructed and tested in a dedicated cryogenic facility at CERN. To simulate the final thermal and hydraulic operating conditions, the B0 was cooled by a forced flow of 4.5 K saturated liquid helium provided by a centrifugal pump of 80 g/s nominal capacity. Both static and dynamic heat loads, generated by the induced currents on the B0 casing during a slow dump or a ramp up, have been measured to verify the expected thermal budget of the entire BT. The instrument used for the heat load measurements was a Void Fraction Meter (VFM) installed on the magnet return line. The instrument constructed at CERN was ca...

  10. Surface cracking of tungsten-vanadium alloys under transient heat loads

    Directory of Open Access Journals (Sweden)

    Kameel Arshad

    2015-07-01

    Full Text Available To evaluate high heat load performance of tungsten-vanadium (W-V alloys as a potential candidate for plasma facing materials of fusion devices, the target materials with three different V concentrations (1, 5 and 10 wt% are exposed to thermal shock loading. The alloys are fabricated by cold isostatic pressing and subsequently sintered in a vacuum furnace. Thereafter, they are exposed to different high heat flux densities ranging from 340 to 675 MW/m2 for single shot of 5 ms duration in an intense electron beam test facility. The alloys with lowest V concentration (1 wt% are highly damaged in form of seriously cracking. The ones with intermediate V content (5 wt% has shown comparatively better performance than both highest and lowest V contents alloys. The results indicate that improved mechanical properties and reduced thermal conductivity due to V addition comprehensively affect the cracking behavior of W-V alloy under transient thermal shock.

  11. Coupled Kinetic-MHD Simulations of Divertor Heat Load with ELM Perturbations

    Science.gov (United States)

    Cummings, Julian; Chang, C. S.; Park, Gunyoung; Sugiyama, Linda; Pankin, Alexei; Klasky, Scott; Podhorszki, Norbert; Docan, Ciprian; Parashar, Manish

    2010-11-01

    The effect of Type-I ELM activity on divertor plate heat load is a key component of the DOE OFES Joint Research Target milestones for this year. In this talk, we present simulations of kinetic edge physics, ELM activity, and the associated divertor heat loads in which we couple the discrete guiding-center neoclassical transport code XGC0 with the nonlinear extended MHD code M3D using the End-to-end Framework for Fusion Integrated Simulations, or EFFIS. In these coupled simulations, the kinetic code and the MHD code run concurrently on the same massively parallel platform and periodic data exchanges are performed using a memory-to-memory coupling technology provided by EFFIS. The M3D code models the fast ELM event and sends frequent updates of the magnetic field perturbations and electrostatic potential to XGC0, which in turn tracks particle dynamics under the influence of these perturbations and collects divertor particle and energy flux statistics. We describe here how EFFIS technologies facilitate these coupled simulations and discuss results for DIII-D, NSTX and Alcator C-Mod tokamak discharges.

  12. RELATIONSHIP BETWEEN BLOOD LACTATE AND HYPERVENTILATION DURING HIGH-INTENSITY CONSTANT-LOAD EXERCISE IN HEAT

    Directory of Open Access Journals (Sweden)

    T. Chiba

    2011-09-01

    Full Text Available The purpose of this study was to examine the relationship between hyperventilation and increase in blood lactate during high-intensity constant-load exercise in heat and normal conditions. Seven male volunteers exercised for 10 min on a cycle ergometer at 80%·VO2max in heat (40ºC, 50%relative humidity: HT and normal conditions (20ºC, 50% relative humidity: CON. Oxygen uptake, carbon dioxide output, ventilation, blood lactate and blood electrolytes (K , Na , Cl− were measured in HT and CON. We found that ventilation was significantly higher during exercise in HT compared with CON (p<0.05 and RER tends to be higher in HT than in CON. Blood lactate was significantly higher at 3 min during exercise in HT compared with CON (5.96 ± 0.57 mEq·l-1 5.00 ± 0.28 mEq·l-1, p<0.05. Change in strong ion difference [∆SID = (∆K ∆Na − (∆Cl− ∆La−], which affects ∆HCO3− in blood significantly, was lower at 5 min during exercise in HT compared with in CON (p<0.05. These results suggest that hyperventilation during exercise in heat would induce lower HCO3− in blood and consequently would result in an increase in blood lactate at an earlier time during high-intensity exercise in heat. It was concluded that hyperventilation during short-term high-intensity exercise in heat is temporarily associated with an increase in blood lactate.

  13. Performance Test of Korea Heat Load Test Facility (KoHLT-EB) for the Plasma Facing Components of Fusion Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Suk-Kwon; Jin, Hyung Gon; Lee, Eo Hwak; Yoon, Jae-Sung; Lee, Dong Won [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Cho, Seungyon [National Fusion Research Institute, Daejeon (Korea, Republic of)

    2014-10-15

    The main components of the plasma facing components (PFCs) in the tokamak are the blanket first wall and divertor, which include the armour materials, the heat sink with the cooling mechanism, and the diagnostics devices for the temperature measurement. The Korea Heat Load Test facility by using electron beam (KoHLT-EB) has been operating for the plasma facing components to develop fusion engineering. This electron beam facility was constructed using a 300 kW electron gun and a cylindrical vacuum chamber. Performance tests were carried out for the calorimetric calibrations with Cu dummy mockup and for the heat load test of large Cu module. For the simulation of the heat load test of each mockup, the preliminary thermal-hydraulic analyses with ANSYS-CFX were performed. For the development of the plasma facing components in the fusion reactors, test mockups were fabricated and tested in the high heat flux test facility. To perform a beam profile test, an assessment of the possibility of electron beam Gaussian power density profile and the results of the absorbed power for that profile before the test starts are needed. To assess the possibility of a Gaussian profile, for the qualification test of the Gaussian heat load profile, a calorimeter mockup and large Cu module were manufactured to simulate real heat. For this high-heat flux test, the Korean high-heat flux test facility using an electron beam system was constructed. In this facility, a cyclic heat flux test will be performed to measure the surface heat flux, surface temperature profile, and cooling capacity.

  14. Oxide segregation and melting behavior of transient heat load exposed beryllium

    Science.gov (United States)

    Spilker, B.; Linke, J.; Pintsuk, G.; Wirtz, M.

    2016-10-01

    In the experimental fusion reactor ITER, beryllium will be applied as first wall armor material. However, the ITER-like wall project at JET already experienced that the relatively low melting temperature of beryllium can easily be exceeded during plasma operation. Therefore, a detailed study was carried out on S-65 beryllium under various transient, ITER-relevant heat loads that were simulated in the electron beam facility JUDITH 1. Hereby, the absorbed power densities were in the range of 0.15-1.0 GW m-2 in combination with pulse durations of 1-10 ms and pulse numbers of 1-1000. In metallographic cross sections, the emergence of a transition region in a depth of ~70-120 µm was revealed. This transition region was characterized by a strong segregation of oxygen at the grain boundaries, determined with energy dispersive x-ray spectroscopy element mappings. The oxide segregation strongly depended on the maximum temperature reached at the end of the transient heat pulse in combination with the pulse duration. A threshold for this process was found at 936 °C for a pulse duration of 10 ms. Further transient heat pulses applied to specimens that had already formed this transition region resulted in the overheating and melting of the material. The latter occurred between the surface and the transition region and was associated with a strong decrease of the thermal conductivity due to the weakly bound grains across the transition region. Additionally, the transition region caused a partial separation of the melt layer from the bulk material, which could ultimately result in a full detachment of the solidified beryllium layers from the bulk armor. Furthermore, solidified beryllium filaments evolved in several locations of the loaded area and are related to the thermally induced crack formation. However, these filaments are not expected to account for an increase of the beryllium net erosion.

  15. Air-to-Water Heat Pumps With Radiant Delivery in Low-Load Homes

    Energy Technology Data Exchange (ETDEWEB)

    Backman, C.; German, A.; Dakin, B.; Springer, D.

    2013-12-01

    Space conditioning represents nearly 50% of average residential household energy consumption, highlighting the need to identify alternative cost-effective, energy-efficient cooling and heating strategies. As homes are better built, there is an increasing need for strategies that are particularly well suited for high performance, low load homes. ARBI researchers worked with two test homes in hot-dry climates to evaluate the in-situ performance of air-to-water heat pump (AWHP) systems, an energy efficient space conditioning solution designed to cost-effectively provide comfort in homes with efficient, safe, and durable operation. Two monitoring projects of test houses in hot-dry climates were initiated in 2010 to test this system. Both systems were fully instrumented and have been monitored over one year to capture complete performance data over the cooling and heating seasons. Results are used to quantify energy savings, cost-effectiveness, and system performance using different operating modes and strategies. A calibrated TRNSYS model was developed and used to evaluate performance in various climate regions. This strategy is most effective in tight, insulated homes with high levels of thermal mass (i.e. exposed slab floors).

  16. Air-to-Water Heat Pumps With Radiant Delivery in Low-Load Homes

    Energy Technology Data Exchange (ETDEWEB)

    Backman, C. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States); German, A. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States); Dakin, B. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States); Springer, D. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States)

    2013-12-01

    Space conditioning represents nearly 50% of average residential household energy consumption, highlighting the need to identify alternative cost-effective, energy-efficient cooling and heating strategies. As homes are better built, there is an increasing need for strategies that are particularly well suited for high performance, low load homes. ARBI researchers worked with two test homes in hot-dry climates to evaluate the in-situ performance of air-to-water heat pump systems, an energy efficient space conditioning solution designed to cost-effectively provide comfort in homes with efficient, safe, and durable operation. Two monitoring projects of test houses in hot-dry climates were initiated in 2010 to test this system. Both systems were fully instrumented and have been monitored over one year to capture complete performance data over the cooling and heating seasons. Results are used to quantify energy savings, cost-effectiveness, and system performance using different operating modes and strategies. A calibrated TRNSYS model was developed and used to evaluate performance in various climate regions. This strategy is most effective in tight, insulated homes with high levels of thermal mass (i.e. exposed slab floors).

  17. Specific Aspects Regarding Coupled Numerical Modeling of Inverter and Load Equipments in an Induction Heating Installation

    Directory of Open Access Journals (Sweden)

    Claudiu MICH-VANCEA

    2008-05-01

    Full Text Available The most propitious projection of inductiveelectrothermic installation requires a deep study ofcoupled electrothermic and circuits problems; thereforethe present paper follows the same line. Research inspecific literature have emphasized that induction heatinghas a much higher efficiency if the supply of the charge(inductor – piece is done at frequencies other thatindustrial one. [1]. Due to material alter depending ontemperature and, implicitly, the variation of the electricalparameters of the heating installation it is necessary totackle the projection of these inductive electrothermicinstallation projected through coupled numericalmodeling of the inverter circuit and of the heatingthrough induction process. The paper presents thenumerical modeling of the continuous current –alternating current conversion bridge (inverter withelements of static switch – over, the type of commandsignal (PWM of elements of static switch of power, thenumerical modeling of the heating throughelectromagnetic induction process and aspects ofcorrelation regarding the functioning/ working of theinstallation depending on the parameters of the load. Theparameters get modified due to material alter dependingon temperature during the heating process.

  18. Urban summer heat load. Meteorological data as a proxy for metropolitan biodiversity

    Energy Technology Data Exchange (ETDEWEB)

    Kappes, Heike [Naturalis Biodiversity Center, Leiden (Netherlands); Katzschner, Lutz [Kassel Univ. (Germany). Environmental Meteorological Dept.; Nowak, Carsten [Senckenberg Gesellschaft fuer Naturforschung, Gelnhausen (Germany). Conservation Genetics Section; Biodiversity and Climate Research Centre (BiK-F), Frankfurt am Main (Germany)

    2012-10-15

    Regional climate models forecast that the incidence of extreme heat waves will increase in Central Europe, and the associated intensification of urban heat islands causes concerns about human health and biodiversity. We investigated species diversity of terrestrial gastropods across an urban gradient in a metropolitan area. We considered 34 sites of different degrees of urbanization and of different thermal stress classes (TSC) that were derived from a classification of urban heat load based on the physiological equivalent temperature (PET). A total of 31 species were recorded with 0-21 species per site (mean: 4.4 {+-} 5.2 species per site). Alpha diversity was best explained by TSC, bush cover and perennial vegetation cover, and it decreased with increasing thermal stress. Overall, thermal stress predicted snail and slug species richness better than urban cover (ANOVA(analysis of variance); TSC: F = 10.0, p < 0.001; urbanization: F = 3.9, p = 0.018), and the proportional loss in species richness was higher for native species than for introduced species. The results indicate that climatic stress contributes to the impoverishment of biodiversity in urban areas. We propose that TSC and/or PET are useful indicators for environmental stress levels in biodiversity studies in natural and anthropogenically transformed landscapes. (orig.)

  19. Three-dimensional numerical analysis of convection and conduction cooling of spherical biocrystals with localized heating from synchrotron X-ray beams.

    Science.gov (United States)

    Mhaisekar, Ashutosh; Kazmierczak, Michael J; Banerjee, Rupak

    2005-05-01

    The differential momentum and thermal energy equations for fluid flow and convective heat-transfer around the sample biocrystal, with coupled internal heat conduction, are solved using advanced computational fluid dynamics techniques. Average \\bar{h} as well as local h(theta) values of the convective heat-transfer coefficients are obtained from the fundamental equations. The results of these numerical solutions show the three-dimensional fluid flow field around the sample in conjunction with the detailed internal temperature distribution inside the crystal. The external temperature rise and maximum internal temperature increase are reported for various cases. The effect of the important system parameters, such as gas velocity and properties, crystal size and thermal conductivity and incident beam conditions (intensity and beam size), are all illustrated with comparative examples. For the reference case, an external temperature rise of 7 K and internal temperature increase of 0.5 K are calculated for a 200 microm-diameter cryocooled spherical biocrystal subjected to a 13 keV X-ray beam of 4 x 10(14) photons s(-1) mm(-2) flux density striking half the sample. For all the cases investigated, numerical analysis shows that the controlling thermal resistance is the rate of convective heat-transfer and not internal conduction. Thermal diffusion results in efficient thermal spreading of the deposited energy and this results in almost uniform internal crystal temperatures (DeltaT(internal) approximately 0.5 K), in spite of the non-uniform h(theta) with no more than 1.3 K internal temperature difference for the worst case of localized and focused beam heating. Rather, the major temperature variation occurs between the outer surface of the crystal/loop system and the gas stream, T(s) - T(gas), which itself is only about DeltaT(external) approximately 5-10 K, and depends on the thermal loading imposed by the X-ray beam, the rate of convection and the size of the loop

  20. INDUSTRIAL CARBON DIOXIDE HEAT PUMP STATION WITH EVAPORATORS WORKING AT VARIOUS TEMPERATURE LEVELS AND AT VARIABLE LOAD

    Directory of Open Access Journals (Sweden)

    Sit M.L.

    2010-08-01

    Full Text Available The block diagram of an industrial carbon dioxide heat pump working in a supercritical cycle, with two evaporators included in parallel working at different temperature levels (mainly for wine-making factories is developed. Heat pump is intended for simultaneous production of heat and cold and works at variable thermal loading. It is shown, how an ejector inclusion in the heat pump scheme provides growth of its thermal efficiency. The way of construction of the hydraulic scheme and a control system provides full controllability of the thermal pump.

  1. Method to Estimate Long-term Change of Heat and Electric Power Daily Load Curves in Japan

    Science.gov (United States)

    Oda, Takuya; Akisawa, Atushi; Kashiwagi, Takao

    The rapid spread of CHP systems will put pressure on the regional power system to requiring an examination of the power and heat output of CHP systems. When considering the country-wide potential of the CHP system one should examine such system in coordination with the grid power system. It is essential to calculate the heat and power demand at end-use level. In the paper, annual heat and power demands of end-use sectors are forecast to the year 2025 based on 20 year data. Regression analysis is used. Estimated annual demands are divided into the seasonal hourly demands considering demand characteristics. Daily load curves of heat and power demands are determined for the Japanese end-use sectors, and the annual changes of such demands are shown by duration curves of heat to power ratios. Moreover, the grid power daily load curves are computed numerically from the estimated heat and power demands at manufacturing, residential and commercial sectors. Such load curves also consider self-generated power at manufacturing industry and own consumption of the grid power. Estimating heat and power demands allow for a joint analysis between the power system and the future phasing in of CHP systems.

  2. ELM simulation experiments using transient heat and particle load produced by a magnetized coaxial plasma gun

    Science.gov (United States)

    Shoda, K.; Sakuma, I.; Iwamoto, D.; Kikuchi, Y.; Fukumoto, N.; Nagata, M.

    2011-10-01

    It is considered that thermal transient events such as type I edge-localized modes (ELMs) and disruptions will limit the lifetime of plasma-facing components (PFCs) in ITER. It is predicted that the heat load onto the PFCs during type I ELMs in ITER is 0.2-2MJ/m2 with pulse length of ~0.1-1ms. We have investigated interaction between transient heat and particle load and the PFCs by using a magnetized coaxial plasma gun (MCPG) at University of Hyogo. In the experiment, a pulsed plasma with duration of ~0.5ms, incident ion energy of ~30eV, and surface absorbed energy density of ~0.3-0.7MJ/m2 was produced by the MCPG. However, no melting occurred on a tungsten surface exposed to a single plasma pulse of ~0.7MJ/m2, while cracks clearly appeared at the edge part of the W surface. Thus, we have recently started to improve the performance of the MCPG in order to investigate melt layer dynamics of a tungsten surface such as vapor cloud formation. In the modified MCPG, the capacitor bank energy for the plasma discharge is increased from 24.5 kJ to 144 kJ. In the preliminary experiments, the plasmoid with duration of ~0.6 ms, incident ion energy of ~ 40 eV, and the surface absorbed energy density of ~2 MJ/m2 was successfully produced at the gun voltage of 6 kV.

  3. Thermal models of buildings. Determination of temperatures, heating and cooling loads. Theories, models and computer programs

    Energy Technology Data Exchange (ETDEWEB)

    Kaellblad, K.

    1998-05-01

    The need to estimate indoor temperatures, heating or cooling load and energy requirements for buildings arises in many stages of a buildings life cycle, e.g. at the early layout stage, during the design of a building and for energy retrofitting planning. Other purposes are to meet the authorities requirements given in building codes. All these situations require good calculation methods. The main purpose of this report is to present the authors work with problems related to thermal models and calculation methods for determination of temperatures and heating or cooling loads in buildings. Thus the major part of the report deals with treatment of solar radiation in glazing systems, shading of solar and sky radiation and the computer program JULOTTA used to simulate the thermal behavior of rooms and buildings. Other parts of thermal models of buildings are more briefly discussed and included in order to give an overview of existing problems and available solutions. A brief presentation of how thermal models can be built up is also given and it is a hope that the report can be useful as an introduction to this part of building physics as well as during development of calculation methods and computer programs. The report may also serve as a help for the users of energy related programs. Independent of which method or program a user choose to work with it is his or her own responsibility to understand the limits of the tool, else wrong conclusions may be drawn from the results 52 refs, 22 figs, 4 tabs

  4. α-Tocopherol-loaded niosome prepared by heating method and its release behavior.

    Science.gov (United States)

    Basiri, Ladan; Rajabzadeh, Ghadir; Bostan, Aram

    2017-04-15

    α-Tocopherol-loaded niosome was developed using modified heating method. The influence of surfactants (Span60 and Tween60) in different mole ratios, presence or absence of cholesterol (Chol) and dicetyl phosphate (DCP) as well as different concentration of α-tocopherol (α-TOC) on mean size, polydispersity index, zeta potential and entrapment efficiency (EE) was evaluated. The results showed that α-TOC loaded niosomes exhibited a small mean size (73.85±0.6-186±0.58nm), narrow size distribution and high EE (61.13±0.52-98.92±0.92). By decreasing the HLB, the EE and stability of the niosomes increased. The DCP and Chol improved the physicochemical properties of niosomes. 3:1 mole ratio of Span 60:Tween 60, 4mg/ml of α-TOC and 25:12.5:2.5 mole ratio of surfactant:Chol:DCP was the optimum formulation in the encapsulation of α-TOC applying niosome system. The niosomes had sustained release profile in the simulated gastric and intestinal fluid.

  5. Thermal Energy Storage for Building Load Management: Application to Electrically Heated Floor

    Directory of Open Access Journals (Sweden)

    Hélène Thieblemont

    2016-07-01

    Full Text Available In cold climates, electrical power demand for space conditioning becomes a critical issue for utility companies during certain periods of the day. Shifting a portion or all of it to off-peak periods can help reduce peak demand and reduce stress on the electrical grid. Sensible thermal energy storage (TES systems, and particularly electrically heated floors (EHF, can store thermal energy in buildings during the off-peak periods and release it during the peak periods while maintaining occupants’ thermal comfort. However, choosing the type of storage system and/or its configuration may be difficult. In this paper, the performance of an EHF for load management is studied. First, a methodology is developed to integrate EHF in TRNSYS program in order to investigate the impact of floor assembly on the EHF performance. Then, the thermal comfort (TC of the night-running EHF is studied. Finally, indicators are defined, allowing the comparison of different EHF. Results show that an EHF is able to shift 84% of building loads to the night while maintaining acceptable TC in cold climate. Moreover, this system is able to provide savings for the customer and supplier if there is a significant difference between off-peak and peak period electricity prices.

  6. Recrystallization and grain growth behavior of rolled tungsten under VDE-like short pulse high heat flux loads

    Science.gov (United States)

    Yuan, Y.; Greuner, H.; Böswirth, B.; Krieger, K.; Luo, G.-N.; Xu, H. Y.; Fu, B. Q.; Li, M.; Liu, W.

    2013-02-01

    Short pulse heat loads expected for vertical displacement events (VDEs) in ITER were applied in the high heat flux (HHF) test facility GLADIS at IPP-Garching onto samples of rolled W. Pulsed neutral beams with the central heat flux of 23 MW/m2 were applied for 0.5, 1.0 and 1.5 s, respectively. Rapid recrystallization of the adiabatically loaded 3 mm thick samples was observed when the pulse duration was up to 1.0 s. Grains grew markedly following recrystallization with increasing pulse length. The recrystallization temperature and temperature dependence of the recrystallized grain size were also investigated. The results showed that the recrystallization temperature of the W grade was around 2480 °C under the applied heat loading condition, which was nearly 1150 °C higher than the conventional recrystallization temperature, and the grains were much finer. A linear relationship between the logarithm of average grain size (ln d) and the inverse of maximum surface temperature (1/Tmax) was found and accordingly the activation energy for grain growth in temperature evolution up to Tmax in 1.5 s of the short pulse HHF load was deduced to be 4.1 eV. This provided an effective clue to predict the structure evolution under short pulse HHF loads.

  7. Electric Heating Property from Butyl Rubber-Loaded Boron Carbide Composites

    Institute of Scientific and Technical Information of China (English)

    MENG Dechuan; WANG Ninghui; LI Guofeng

    2014-01-01

    We researched the electric heating property from butyl rubber-loaded boron carbide composite. The effects of boron carbide content on bulk resistivity, voltage-current characteristic, thermal conductivity and thermal stability of boron carbide/butyl rubber (IIR) polymer composite were introduced. The analysis results indicated that the bulk resistivity decreased greatly with increasing boron carbide content, and when boron carbide content reached to 60%, the bulk resistivity achieved the minimum. Accordingly, electric heating behavior of the composite is strongly dependent on boron carbide content as well as applied voltage. The content of boron carbide was found to be effective in achieving high thermal conductivity in composite systems. The thermal conductivity of the composite material with added boron carbide was improved nearly 20 times than that of the pure IIR. The thermal stability test showed that, compared with pure IIR, the thermal stable time of composites was markedly extended, which indicated that the boron carbide can significantly improve the thermal stability of boron carbide/IIR composite.

  8. Tympanic temperature in confined beef cattle exposed to excessive heat load

    Science.gov (United States)

    Mader, T. L.; Gaughan, J. B.; Johnson, L. J.; Hahn, G. L.

    2010-11-01

    Angus crossbred yearling steers ( n = 168) were used to evaluate effects on performance and tympanic temperature (TT) of feeding additional potassium and sodium to steers exposed to excessive heat load (maximum daily ambient temperature exceeded 32°C for three consecutive days) during seasonal summer conditions. Steers were assigned one of four treatments: (1) control; (2) potassium supplemented (diet containing 2.10% KHCO3); (3) sodium supplemented (diet containing 1.10% NaCl); or (4) potassium and sodium supplemented (diet containing 2.10% KHCO3 and 1.10% NaCl). Overall, additional KHCO3 at the 2% level or NaCl at the 1% level did not improve performance or heat stress tolerance with these diet formulations. However, the addition of KHCO3 did enhance water intake. Independent of treatment effects, TT of cattle displaying high, moderate, or low levels of stress suggest that cattle that do not adequately cool down at night are prone to achieving greater body temperatures during a subsequent hot day. Cattle that are prone to get hot but can cool at night can keep average tympanic temperatures at or near those of cattle that tend to consistently maintain lower peak and mean body temperatures. In addition, during cooler and moderately hot periods, cattle change TT in a stair-step or incremental pattern, while under hot conditions, average TT of group-fed cattle moves in conjunction with ambient conditions, indicating that thermoregulatory mechanisms are at or near maximum physiological capacity.

  9. FLASHPOINT - a tool to routinely calculate the heat load in the irradiated fuel bays

    Energy Technology Data Exchange (ETDEWEB)

    Vyskocil, E.; Morrison, C.; Gifford, E.; Inglot, A.; Kozlowski, K.; Gocmanac, M. [AMEC NSS, Reactor and Radiation Physics, Toronto, Ontario (Canada); Parlatan, Y. [Ontario Power Generation, Safety Analysis Improvement Project Dept., Pickering, Ontario (Canada); Alabasha, H. [Bruce Power, Nuclear Safety Analysis and Support, Toronto, Ontario (Canada)

    2013-07-01

    At the recommendation of the World Association of Nuclear Operators (WANO), a tool was developed as an enhancement of NuFLASH (Nuclear Fuel Location and Storage History) in order to routinely calculate the Irradiated Fuel Bay (IFB) heat load. It uses information stored in NuFLASH regarding the location and details of spent fuel bundle properties to calculate the decay power on a bundle by bundle basis and then sum the decay powers of all bundles in a particular IFB. FLASHPOINT employs a two-step approximation of the bundle irradiation history based on the record of the life cycle for each individual fuel bundle. The primary parameter affecting the decay power of any individual irradiated CANDU fuel bundle following its discharge from core is the period of time elapsed since the bundle last operated at power within the reactor. The remaining factors influencing the decay power of an individual fuel bundle concern the irradiation history of that bundle while in core. The accuracy of the FLASHPOINT methodology has been assessed primarily through comparison of results obtained using the two step history representation implemented in FLASHPOINT against results from a more detailed ORIGEN-S calculation of the decay heat based on the SORO power history for a randomly selected sample of bundles. The results for individual bundles and the aggregate group are presented and the accuracy of the two-step approximation is demonstrated to be acceptable. (author)

  10. Revised Heating Load Line Analysis: Addendum to ORNL/TM-2015/281

    Energy Technology Data Exchange (ETDEWEB)

    Rice, C. Keith [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Shen, Bo [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Shrestha, Som S. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-07-01

    The original heating load line analysis of ORNL TM-2015/281 was modified to incorporate two adjustments of (1) removing mechanical ventilation and (2) resizing the heat pump units based on new criteria. This resulted in a lowering of the HLL slope factor from the originally rounded 1.3 level to 1.15 in DOE Region IV and V while leaving unchanged the zero-load ambient at a rounded value of 55 F. For the other four DOE regions, the zero-load ambients dropped by 1 to 2 F from those found earlier and the rounded HLL slope factors ranged from 1.05 to 1.3. The average rounded HLL slope factor over all six DOE regions is 1.15. Effects of the revised slope factor on rated HSPFs (Region IV) for single- and two-capacity units dropped from 16% in the original work to 12.6% in this report. For VS units, the HSPF reductions of 14 to 25% in the original report were lowered to a range of 9 to 21%. As in the original report, for VS units that do not limit minimum speed operation below 47 F ambient, the average HSPF reduction for the cases evaluated is approximately the same as for single- and two-capacity units. For VS units that do limit minimum speed operation below 47 F ambient, the lower 1.15 slope factor of this report generally results in small overpredictions of rated HSPF by 1 to 3% compared to functional HSPF. An exception is minimum-speed-limited VS units where the minimum speed COP at 47 F is higher than that at 62 F; one such unit was found to have an HSPF overprediction of over 14% with the 1.15 HLL slope factor level. For such VS exception cases, a default HSPF penalty should be considered. For the more typical VS units that limit minimum speed operation, use of a 1.15 slope factor for rated HSPF was found to still acceptably limit the HSPF error. If slope factors lower than 1.15 are used for HSPF ratings, some means should be considered to appropriately derate the HSPFs for VS units which limit minimum speed operation below 47 F ambient.

  11. Multiharmonic rf feedforward system for compensation of beam loading and periodic transient effects in magnetic-alloy cavities of a proton synchrotron

    Science.gov (United States)

    Tamura, Fumihiko; Ohmori, Chihiro; Yamamoto, Masanobu; Yoshii, Masahito; Schnase, Alexander; Nomura, Masahiro; Toda, Makoto; Shimada, Taihei; Hasegawa, Katsushi; Hara, Keigo

    2013-05-01

    Beam loading compensation is a key for acceleration of a high intensity proton beam in the main ring (MR) of the Japan Proton Accelerator Research Complex (J-PARC). Magnetic alloy loaded rf cavities with a Q value of 22 are used to achieve high accelerating voltages without a tuning bias loop. The cavity is driven by a single harmonic (h=9) rf signal while the cavity frequency response also covers the neighbor harmonics (h=8,10). Therefore the wake voltage induced by the high intensity beam consists of the three harmonics, h=8,9,10. The beam loading of neighbor harmonics is the source of periodic transient effects and a possible source of coupled bunch instabilities. In the article, we analyze the wake voltage induced by the high intensity beam. We employ the rf feedforward method to compensate the beam loading of these three harmonics (h=8,9,10). The full-digital multiharmonic feedforward system was developed for the MR. We describe the system architecture and the commissioning methodology of the feedforward patterns. The commissioning of the feedforward system has been performed by using high intensity beams with 1.0×1014 proteins per pulse. The impedance seen by the beam is successfully reduced and the longitudinal oscillations due to the beam loading are reduced. By the beam loading compensation, stable high power beam operation is achieved. We also report the reduction of the momentum loss during the debunching process for the slow extraction by the feedforward.

  12. Study of heat and synchrotron radiation transport in fusion tokamak plasmas. Application to the modelling of steady state and fast burn termination scenarios for the international experimental fusion reactor ITER

    Energy Technology Data Exchange (ETDEWEB)

    Villar Colome, J. [Association Euratom-CEA, Centre d`Etudes de Cadarache, 13 - Saint-Paul-lez-Durance (France). Dept. de Recherches sur la Fusion Controlee]|[Universitat Polytechnica de Catalunya (Spain)

    1997-12-01

    The aim of this thesis is to give a global scope of the problem of energy transport within a thermonuclear plasma in the context of its power balance and the implications when modelling ITER operating scenarios. This is made in two phases. First, by furnishing new elements to the existing models of heat and synchrotron radiation transport in a thermonuclear plasma. Second, by applying the improved models to plasma engineering studies of ITER operating scenarios. The scenarios modelled are the steady state operating point and the transient that appears to have the biggest technological implications: the fast burn termination. The conduction-convection losses are modelled through the energy confinement time. This parameter is empirically obtained from the existing experimental data, since the underlying mechanisms are not well understood. In chapter 2 an expression for the energy confinement time is semi-analytically deduced from the Rebut-Lallia-Watkins local transport model. The current estimates of the synchrotron radiation losses are made with expressions of the dimensionless transparency factor deduced from a 0-dimensional cylindrical model proposed by Trubnikov in 1979. In chapter 3 realistic hypothesis for the cases of cylindrical and toroidal geometry are included in the model to deduce compact explicit expressions for the fast numerical computation of the synchrotron radiation losses. Numerical applications are provided for the cylindrical case. The results are checked against the existing models. In chapter 4, the nominal operating point of ITER and its thermal stability is studied by means of a 0-dimensional burn model of the thermonuclear plasma in ignition. This model is deduced by the elements furnished by the plasma particle and power balance. Possible heat overloading on the plasma facing components may provoke severe structural damage, implying potential safety problems related to tritium inventory and metal activation. In chapter 5, the assessment

  13. Synchrotron X-ray adaptative monochromator: study and realization of a prototype; Monochromateur adaptatif pour rayonnement X synchrotron: etude et realisation d`un prototype

    Energy Technology Data Exchange (ETDEWEB)

    Dezoret, D.

    1995-12-12

    This work presents a study of a prototype of a synchrotron X-ray monochromator. The spectral qualities of this optic are sensitive to the heat loads which are particularly important on third synchrotron generation like ESRF. Indeed, powers generated by synchrotron beams can reach few kilowatts and power densities about a few tens watts per square millimeters. The mechanical deformations of the optical elements of the beamlines issue issue of the heat load can damage their spectral efficiencies. In order to compensate the deformations, wa have been studying the transposition of the adaptive astronomical optics technology to the x-ray field. First, we have considered the modifications of the spectral characteristics of a crystal induced by x-rays. We have established the specifications required to a technological realisation. Then, thermomechanical and technological studies have been required to transpose the astronomical technology to an x-ray technology. After these studies, we have begun the realisation of a prototype. This monochromator is composed by a crystal of silicon (111) bonded on a piezo-electric structure. The mechanical control is a loop system composed by a infrared light, a Shack-Hartmann CDD and wave front analyser. This system has to compensate the deformations of the crystal in the 5 kcV to 60 kcV energy range with a power density of 1 watt per square millimeters. (authors).

  14. Thermal management of next-generation contact-cooled synchrotron x-ray mirrors

    Energy Technology Data Exchange (ETDEWEB)

    Khounsary, A.

    1999-10-29

    In the past decade, several third-generation synchrotrons x-ray sources have been constructed and commissioned around the world. Many of the major problems in the development and design of the optical components capable of handling the extremely high heat loads of the generated x-ray beams have been resolved. It is expected, however, that in the next few years even more powerful x-ray beams will be produced at these facilities, for example, by increasing the particle beam current. In this paper, the design of a next generation of synchrotron x-ray mirrors is discussed. The author shows that the design of contact-cooled mirrors capable of handing x-ray beam heat fluxes in excess of 500 W/mm{sup 2} - or more than three times the present level - is well within reach, and the limiting factor is the thermal stress rather then thermally induced slope error.

  15. Recrystallization and grain growth behavior of rolled tungsten under VDE-like short pulse high heat flux loads

    Energy Technology Data Exchange (ETDEWEB)

    Yuan, Y. [Laboratory of Advanced Materials, Department of Material Science and Engineering, Tsinghua University, Beijing 100084 (China); Greuner, H.; Böswirth, B.; Krieger, K. [Max-Planck-Institut für Plasmaphysik, EURATOM Association, 85748 Garching (Germany); Luo, G.-N. [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui 230031 (China); Xu, H.Y.; Fu, B.Q.; Li, M. [Laboratory of Advanced Materials, Department of Material Science and Engineering, Tsinghua University, Beijing 100084 (China); Liu, W., E-mail: liuw@mail.tsinghua.edu.cn [Laboratory of Advanced Materials, Department of Material Science and Engineering, Tsinghua University, Beijing 100084 (China)

    2013-02-15

    Highlights: ► Recrystallization temperature of a rolled W was ∼2480 °C under applied HHF loads. ► Fine grains were obtained under HHF loads with appropriate short pulse length. ► With increasing pulse length, the recrystallized grains significantly grew larger. ► A linear relationship between ln d and 1/T{sub max} was found. ► Activation energy for grain growth in T evolution up to T{sub max} in 1.5 s was obtained. -- Abstract: Short pulse heat loads expected for vertical displacement events (VDEs) in ITER were applied in the high heat flux (HHF) test facility GLADIS at IPP-Garching onto samples of rolled W. Pulsed neutral beams with the central heat flux of 23 MW/m{sup 2} were applied for 0.5, 1.0 and 1.5 s, respectively. Rapid recrystallization of the adiabatically loaded 3 mm thick samples was observed when the pulse duration was up to 1.0 s. Grains grew markedly following recrystallization with increasing pulse length. The recrystallization temperature and temperature dependence of the recrystallized grain size were also investigated. The results showed that the recrystallization temperature of the W grade was around 2480 °C under the applied heat loading condition, which was nearly 1150 °C higher than the conventional recrystallization temperature, and the grains were much finer. A linear relationship between the logarithm of average grain size (ln d) and the inverse of maximum surface temperature (1/T{sub max}) was found and accordingly the activation energy for grain growth in temperature evolution up to T{sub max} in 1.5 s of the short pulse HHF load was deduced to be 4.1 eV. This provided an effective clue to predict the structure evolution under short pulse HHF loads.

  16. Heat loads on JET plasma facing components from ICRF and LH wave absorption in the SOL

    Science.gov (United States)

    Jacquet, P.; Colas, L.; Mayoral, M.-L.; Arnoux, G.; Bobkov, V.; Brix, M.; Coad, P.; Czarnecka, A.; Dodt, D.; Durodie, F.; Ekedahl, A.; Frigione, D.; Fursdon, M.; Gauthier, E.; Goniche, M.; Graham, M.; Joffrin, E.; Korotkov, A.; Lerche, E.; Mailloux, J.; Monakhov, I.; Noble, C.; Ongena, J.; Petrzilka, V.; Portafaix, C.; Rimini, F.; Sirinelli, A.; Riccardo, V.; Vizvary, Z.; Widdowson, A.; Zastrow, K.-D.; EFDA Contributors, JET

    2011-10-01

    In JET, lower hybrid (LH) and ion cyclotron resonance frequency (ICRF) wave absorption in the scrape-off layer can lead to enhanced heat fluxes on some plasma facing components (PFCs). Experiments have been carried out to characterize these heat loads in order to: (i) prepare JET operation with the Be wall which has a reduced power handling capability as compared with the carbon wall and (ii) better understand the physics driving these wave absorption phenomena and propose solutions for next generation systems to reduce them. When using ICRF, hot spots are observed on the antenna structures and on limiters close to the powered antennas and are explained by acceleration of ions in RF-rectified sheath potentials. High temperatures up to 800 °C can be reached on locations where a deposit has built up on tile surfaces. Modelling which takes into account the fast thermal response of surface layers can reproduce well the surface temperature measurements via infrared (IR) imaging, and allow evaluation of the heat fluxes local to active ICRF antennas. The flux scales linearly with the density at the antenna radius and with the antenna voltage. Strap phasing corresponding to wave spectra with lower kpar values can lead to a significant increase in hot spot intensity in agreement with antenna modelling that predicts, in that case, an increase in RF sheath rectification. LH absorption in front of the antenna through electron Landau damping of the wave with high Npar components generates hot spots precisely located on PFCs magnetically connected to the launcher. Analysis of the LH hot spot surface temperature from IR measurements allows a quantification of the power flux along the field lines: in the worst case scenario it is in the range 15-30 MW m-2. The main driving parameter is the LH power density along the horizontal rows of the launcher, the heat fluxes scaling roughly with the square of the LH power density. The local electron density in front of the grill increases

  17. Application of silicon carbide to synchrotron-radiation mirrors

    Energy Technology Data Exchange (ETDEWEB)

    Takacs, P.Z.; Hursman, T.L.; Williams, J.T.

    1983-09-01

    Damage to conventional mirror materials exposed to the harsh synchrotron radiation (SR) environment has prompted the SR user community to search for more suitable materials. Next-generation insertion devices, with their attendant flux increases, will make the problem of mirror design even more difficult. A parallel effort in searching for better materials has been underway within the laser community for several years. The technology for dealing with high thermal loads is highly developed among laser manufacturers. Performance requirements for laser heat exchangers are remarkably similar to SR mirror requirements. We report on the application of laser heat exchanger technology to the solution of typical SR mirror design problems. The superior performance of silicon carbide for laser applications is illustrated by various material trades studies, and its superior performance for SR applications is illustrated by means of model calculations.

  18. Enhancement of urban heat load through social inequalities on an example of a fictional city King's Landing

    Science.gov (United States)

    Žuvela-Aloise, M.

    2017-03-01

    The numerical model MUKLIMO_3 is used to simulate the urban climate of an imaginary city as an illustrative example to demonstrate that the residential areas with deprived socio-economic conditions can exhibit an enhanced heat load at night, and thus more disadvantageous environmental conditions, compared with the areas of higher socio-economic status. The urban climate modelling simulations differentiate between orographic, natural landscape, building and social effects, where social differences are introduced by selection of location, building type and amount of vegetation. The model results show that the increase of heat load can be found in the areas inhabited by the poor population as a combined effect of natural and anthropogenic factors. The unfavourable location in the city and the building type, consisting of high density, low housing with high fraction of pavement and small amount of vegetation contribute to the formation of excessive heat load. This abstract example shows that the enhancement of urban heat load can be linked to the concept of a socially stratified city and is independent of the historical development of any specific city.

  19. Behavioural evidence for heat-load problems in Great Knots in tropical Australia fuelling for long-distance flight

    NARCIS (Netherlands)

    Battley, PF; Rogers, DI; Piersma, T; Koolhaas, A; Battley, Phil F.; Rogers, Danny I.

    2003-01-01

    Migratory shorebirds that live in the tropics prior to embarking on long (> 5000 km) flights may face heat-load problems. The behaviour of a large sandpiper, the Great Knot (Calidris tenuirostris), was studied in Roebuck Bay, north-west Australia, from February to April 2000. We determined the incid

  20. Enhancement of urban heat load through social inequalities on an example of a fictional city King's Landing

    Science.gov (United States)

    Žuvela-Aloise, M.

    2016-08-01

    The numerical model MUKLIMO_3 is used to simulate the urban climate of an imaginary city as an illustrative example to demonstrate that the residential areas with deprived socio-economic conditions can exhibit an enhanced heat load at night, and thus more disadvantageous environmental conditions, compared with the areas of higher socio-economic status. The urban climate modelling simulations differentiate between orographic, natural landscape, building and social effects, where social differences are introduced by selection of location, building type and amount of vegetation. The model results show that the increase of heat load can be found in the areas inhabited by the poor population as a combined effect of natural and anthropogenic factors. The unfavourable location in the city and the building type, consisting of high density, low housing with high fraction of pavement and small amount of vegetation contribute to the formation of excessive heat load. This abstract example shows that the enhancement of urban heat load can be linked to the concept of a socially stratified city and is independent of the historical development of any specific city.

  1. Effect of second-phase particles on the properties of W-based materials under high-heat loading

    Directory of Open Access Journals (Sweden)

    Xiao–Yue Tan

    2016-12-01

    Full Text Available W, W-TaC, and W-TiC materials were subjected to heat–load tests in an electron beam facility (10keV, 8kW at 100 pulses. After heat loading, severe cracks and plastic deformation were detected on the surface of pure W materials. However, plastic deformation was the primary change on the surfaces of W-TaC and W-TiC alloys. This phenomenon was due to the second-phase (TaC and TiC particles dispersed in the W matrix, which strengthened the grain boundaries and prevented crack formation and propagation. In addition, the microhardness of W and W-TiC obviously decreased, whereas that of W-TaC did not change considerably before and after heat loading.

  2. Study of regeneration system of 300 MW power unit based on nondeaerating heat balance diagram at reduced load

    Science.gov (United States)

    Esin, S. B.; Trifonov, N. N.; Sukhorukov, Yu. G.; Yurchenko, A. Yu.; Grigor'eva, E. B.; Snegin, I. P.; Zhivykh, D. A.; Medvedkin, A. V.; Ryabich, V. A.

    2015-09-01

    More than 30 power units of thermal power stations, based on the nondeaerating heat balance diagram, successfully operate in the former Soviet Union. Most of them are power units with a power of 300 MW, equipped with HTGZ and LMZ turbines. They operate according to a variable electric load curve characterized by deep reductions when undergoing night minimums. Additional extension of the range of power unit adjustment makes it possible to maintain the dispatch load curve and obtain profit for the electric power plant. The objective of this research is to carry out estimated and experimental processing of the operating regimes of the regeneration system of steam-turbine plants within the extended adjustment range and under the conditions when the constraints on the regeneration system and its equipment are removed. Constraints concerning the heat balance diagram that reduce the power unit efficiency when extending the adjustment range have been considered. Test results are presented for the nondeaerating heat balance diagram with the HTGZ turbine. Turbine pump and feed electric pump operation was studied at a power unit load of 120-300 MW. The reliability of feed pump operation is confirmed by a stable vibratory condition and the absence of cavitation noise and vibration at a frequency that characterizes the cavitation condition, as well as by oil temperature maintenance after bearings within normal limits. Cavitation performance of pumps in the studied range of their operation has been determined. Technical solutions are proposed on providing a profitable and stable operation of regeneration systems when extending the range of adjustment of power unit load. A nondeaerating diagram of high-pressure preheater (HPP) condensate discharge to the mixer. A regeneration system has been developed and studied on the operating power unit fitted with a deaeratorless thermal circuit of the system for removing the high-pressure preheater heating steam condensate to the mixer

  3. The Australian synchrotron; Le synchrotron australien

    Energy Technology Data Exchange (ETDEWEB)

    Farhi, R

    2005-06-15

    This document recalls the historical aspects of the Australian Synchrotron which will be implemented in 2007. It presents then the objectives of this program, the specifications of the ring and the light lines. (A.L.B.)

  4. Transient Stability Improvement for Combined Heat and Power System Using Load Shedding

    Directory of Open Access Journals (Sweden)

    Hung-Cheng Chen

    2014-01-01

    Full Text Available The purpose of the paper is to analyze and improve the transient stability of an industrial combined heat and power (CHP system in a high-tech science park in Taiwan. The CHP system installed two 161 kV/161 kV high-impendence transformers to connect with Taipower System (TPS for both decreasing the short-circuit fault current and increasing the fault critical clearing time. The transient stabilities of three types of operation modes in CHP units, 3G1S, 2G1S, and 1G1S, are analyzed. Under the 3G1S operation mode, the system frequency is immediately restored to 60 Hz after tie line tripping with the TPS. Under the 1G1S and 2G1S operation modes, the system frequencies will continuously decrease and eventually become unstable. A novel transient stability improvement approach using load shedding technique based on the change in frequency is proposed to improve the transient stability.

  5. Limiter heat loads during the first operation of the W7-X stellarator

    Science.gov (United States)

    Wurden, Glen; Niemann, Holger; Jakubowski, Marcin; Bozhenkov, Sergey; Biedermann, Christoph; Marsen, Stefan; Effenberg, Florian; Stephey, Laurie; Schmitz, Oliver; W7-X Team

    2016-10-01

    During the first operational phase (OP1.1) of the new W7-X stellarator, five poloidal graphite limiters served as the main boundary for the plasma. There was a dedicated set of diagnostics to observe the performance of the temporary poloidal limiters and infer basic transport behavior of the 3-D helical SOL plasma. We describe IR imaging of the limiters, which resulted in observations of 1) heat flux determination as a function of time and space, 2) total energy into the limiters, 3) high-frequency helical patterns of energy bursts onto the limiters, 4) changes in surface emissivity, and 5) detection of UFO's (small-to-large dusts). These measurements were made in 2 magnetic configuration discharges (differing iota), and in ones where the power loads to the limiters were systematically modified by the use of trim coils. Observed power fractions on the limiters ranged from 40% to 20% of the 0.6 to 4 MW ECRH input powers. Acknowledgement: Funded under DOE LANS Contract DE-AC5026NA25396 and DE-SC0014210, and within the EUROfusion Consortium under Euratom Grant 633053.

  6. Affect of Air Leakage into a Thermal-Vacuum Chamber on Helium Refrigeration Heat Load

    Science.gov (United States)

    Garcia, Sam; Meagher, Daniel; Linza, Robert; Saheli, Fariborz; Vargas, Gerardo; Lauterbach, John; Reis, Carl; Ganni, Venkatarao (Rao); Homan, Jonathan

    2008-01-01

    NASA s Johnson Space Center (JSC) Building 32 houses two large thermal-vacuum chambers (Chamber A and Chamber B). Within these chambers are liquid nitrogen shrouds to provide a thermal environment and helium panels which operate at 20K to provide cryopumping. Some amount of air leakage into the chambers during tests is inevitable. This causes "air fouling" of the helium panel surfaces due to the components of the air that adhere to the panels. The air fouling causes the emittance of the helium panels to increase during tests. The increase in helium panel emittance increases the heat load on the helium refrigerator that supplies the 20K helium for those panels. Planning for thermal-vacuum tests should account for this increase to make sure that the helium refrigerator capacity will not be exceeded over the duration of a test. During a recent test conducted in Chamber B a known-size air leak was introduced to the chamber. Emittance change of the helium panels and the affect on the helium refrigerator was characterized. A description of the test and the results will be presented.

  7. Lesson from Tungsten Leading Edge Heat Load Analysis in KSTAR Divertor

    Science.gov (United States)

    Hong, Suk-Ho; Pitts, Richard Anthony; Lee, Hyeong-Ho; Bang, Eunnam; Kang, Chan-Soo; Kim, Kyung-Min; Kim, Hong-Tack; ITER Organization Collaboration; Kstar Team Team

    2016-10-01

    An important design issue for the ITER tungsten (W) divertor and in fact for all such components using metallic plasma-facing elements and which are exposed to high parallel power fluxes, is the question of surface shaping to avoid melting of leading edges. We have fabricated a series of tungsten blocks with a variety of leading edge heights (0.3, 0.6, 1.0, and 2.0 mm), from the ITER worst case to heights even beyond the extreme value tested on JET. They are mounted into adjacent, inertially cooled graphite tile installed in the central divertor region of KSTAR, within the field of view of an infra-red (IR) thermography system with a spatial resolution to 0.4 mm/pixel. Adjustment of the outer divertor strike point position is used to deposit power on the different blocks in different discharges. The measured power flux density on flat regions of the surrounding graphite tiles is used to obtain the parallel power flux, q|| impinging on the various W blocks. Experiments have been performed in Type I ELMing H-mode with Ip = 600 kA, BT = 2 T, PNBI = 3.5 MW, leading to a hot attached divertor with typical pulse lengths of 10 s. Three dimensional ANSYS simulations using q|| and assuming geometric projection of the heat flux are found to be consistent with the observed edge loading. This research was partially supported by Ministry of Science, ICT, and Future Planning under KSTAR project.

  8. On the influence of the urban heat island on the cooling load of a school building in Athens, Greece

    Science.gov (United States)

    Bagiorgas, H. S.; Mihalakakou, G.

    2016-02-01

    The present study investigates the effect of the urban heat island (UHI) phenomenon, measured in the Greater Athens Area (GAA), on the energy consumption of a typical modern school building. The energy performance of the selected building has been calculated using an accurate, extensively validated, transient simulation model for 17 different sites of the GAA, for the summer period. Calculations showed that the urban heat island phenomenon affects remarkably the thermal behavior of the school building, as suburban areas presented much lower cooling loads. The cooling load values fluctuated between 3304.3 kWh for the rural stations and 14,585.1 kWh for the central stations (for the year 2011) or between 3206.5 kWh and 14,208.3 kWh (for the year 2012), respectively. Moreover, the mean monthly cooling load values varied between 0.4-2 kWh/m2 for the rural stations and 4-6.9 kWh/m2 for the central stations, for the selected time period. Furthermore, a neural network model was designed and developed in order to quantify the contribution of various meteorological parameters (such as the mean daily air temperature values, the mean daily solar radiation values, the average wind speed and the urban heat island intensity) to the energy consumption of the building and it was found that the urban heat island intensity is the predominant parameter, influencing remarkably the energy consumption of the typical school building.

  9. Investigations of pulsed heat loads on a forced flow supercritical helium loop. Part B: Simulation of the cryogenic circuit

    Science.gov (United States)

    Vallcorba, R.; Hitz, D.; Rousset, B.; Lagier, B.; Hoa, C.

    2012-07-01

    The VINCENTA software is applied to model the transient thermal-hydraulic flow of the HELIOS supercritical helium circuit. This cryogenic circuit is equipped with dedicated heating to simulate pulsed heat loads - See Part A for the description of the experimental set up. Currently, one of the main important problems to be solved is the control and smoothing of heat pulses in the cryogenic circuit to keep the refrigerator in stable operation. In this context, the aim of the present development is to get a predictive model for the experimental management of overall heat loads absorbed by the refrigerator as well as to better understand the associated physical phenomena. This preliminary model is validated with early experiments performed with the HELIOS test facility which is dedicated to simulate representative pulsed loads related to the Japanese tokamak JT60-SA. This article presents the first comparison between model and experiments for two JT60-SA relevant scaled down pulses: (20 s/600 s-1000 W) and (60 s/1800 s-750 W).

  10. Preliminary study on heat load using calorimetric measurement during long-pulse high-performance discharges on EAST

    Science.gov (United States)

    Liu, Y. K.; Hamada, N.; Hanada, K.; Gao, X.; Liu, H. Q.; Yu, Y. W.; Qian, J. P.; Yang, L.; Xu, T. J.; Jie, Y. X.; Yao, Y.; Wang, S. S.; Xu, J. C.; Yang, Z. D.; Li, G. S.; EAST Team

    2017-04-01

    Experimental Advanced Superconducting Tokamak (EAST) aims to demonstrate steady-state advanced high-performance H-mode plasmas with an ITER-like configuration, plasma control and heating schemes. The plasma-facing components in EAST are actively cooled, providing good conditions for researching long-pulse and high-energy discharges. A long-pulse high-performance plasma discharge (#59892 discharge) of up to 103 s with a core electron temperature of up to 4.5 keV was sustained with an injected energy exceeding 0.22 GJ in the 2015–2016 experimental campaign. A calorimetric measurement utilizing the temperature increment of cooling water is carried out to calculate the heat load on the strike point region of the lower divertor during long-pulse discharges in EAST. For the long-pulse and high-energy discharges, the comparison of the measurement results for the heat load measured by divertor Langmuir probes and the calorimetry diagnostic indicates that most of the heat load is delivered to the divertor panels as plasma, not radiation, and charge exchange neutrals. The ratio of the heat load on the strike point region of the lower divertor to the total injected energy is on average 42.5% per discharge with the lower single null divertor configuration. If the radiated energy loss measured by the fast bolometer diagnostic is taken into consideration, the ratio is found to be 61.6%. The experimental results and the analysis of the physics involved in these discharges are reported and discussed.

  11. Analysis of the temperature and thermal stress in pure tungsten monoblock during heat loading and the influences of alloying and dispersion strengthening on these responses

    Energy Technology Data Exchange (ETDEWEB)

    Fukuda, Makoto, E-mail: makoto.fukuda@qse.tohoku.ac.jp [Tohoku University, 6-6-01-2 Aramaki-aza Aoba, Aobaku, Sendai, 980-8579 (Japan); Nogami, Shuhei; Guan, Wenhai; Hasegawa, Akira [Tohoku University, 6-6-01-2 Aramaki-aza Aoba, Aobaku, Sendai, 980-8579 (Japan); Muroga, Takeo [National Institute for Fusion Science, 322-6 Oroshi-cho, Gifu, 509-5292 (Japan)

    2016-06-15

    Highlights: • The heat load response of pure W and its alloys monoblock was investigated by FEA. • The effect of alloying on heat load response of W was not clearly observed. • The possibility of cracking during cooling phase after heat load was suggested. • The effects of recrystallization and irradiation embrittlement were discussed. • W alloys will show better reliability than pure W during fusion reactor operation. - Abstract: The effects of 3% Re addition and K-bubble dispersion on temperature and stress values and the distributions thereof in a W monoblock during heat loading were investigated using finite element analysis. K-doped W-3%Re exhibited the highest recrystallization resistance but showed a higher surface temperature than pure W or K-doped W during the heat loading. The effect of K-bubble dispersion and 3% Re addition on thermal stress distribution during heat loading was not clearly observed, and residual tensile stress after heat loading, which could possibly cause cracking, was observed at the top surfaces of all materials. Because of the higher strength and temperature at which recrystallization starts for the K-doped W-3%Re and K-doped W, the probability of crack formation at the top surface might be lower compared to that in pure W. The improvement in the material properties and resistance to crack initiation and propagation in W during cyclic heat loading is crucial for the design and development of plasma-facing components. This work suggests possibility of the crack formation in a pure W monoblock in the cooling phase after a 20 MW/m{sup 2} heat loading cycle and the effectiveness of K-bubble dispersion and Re addition for improving the heat loading resistance of monoblock W.

  12. Synchrotron radiation facilities

    CERN Multimedia

    1972-01-01

    Particularly in the past few years, interest in using the synchrotron radiation emanating from high energy, circular electron machines has grown considerably. In our February issue we included an article on the synchrotron radiation facility at Frascati. This month we are spreading the net wider — saying something about the properties of the radiation, listing the centres where synchrotron radiation facilities exist, adding a brief description of three of them and mentioning areas of physics in which the facilities are used.

  13. Numerical study of plasma generation process and internal antenna heat loadings in J-PARC RF negative ion source

    Energy Technology Data Exchange (ETDEWEB)

    Shibata, T., E-mail: shibat@post.j-parc.jp; Ueno, A.; Oguri, H.; Ohkoshi, K.; Ikegami, K.; Takagi, A.; Asano, H.; Naito, F. [J-PARC Center, Tokai-mura, Naka-gun, Ibaraki-ken 319-1195 (Japan); Nishida, K.; Mochizuki, S.; Hatayama, A. [Keio University, Hiyoshi, Kohoku-ku, Yokohama-shi, Kanagawa-ken 223-8522 (Japan); Mattei, S.; Lettry, J. [European Organization for Nuclear Research (CERN), 1211 Geneva 23 (Switzerland)

    2016-02-15

    A numerical model of plasma transport and electromagnetic field in the J-PARC (Japan Proton Accelerator Research Complex) radio frequency ion source has been developed to understand the relation between antenna coil heat loadings and plasma production/transport processes. From the calculation, the local plasma density increase is observed in the region close to the antenna coil. Electrons are magnetized by the magnetic field line with absolute magnetic flux density 30–120 Gauss which leads to high local ionization rate. The results suggest that modification of magnetic configuration can be made to reduce plasma heat flux onto the antenna.

  14. submitter Numerical study of plasma generation process and internal antenna heat loadings in J-PARC RF negative ion source

    CERN Document Server

    Shibata, T; Mochizuki, S; Mattei, S; Lettry, J; Hatayama, A; Ueno, A; Oguri, H; Ohkoshi, K; Ikegami, K; Takagi, A; Asano, H; Naito, F

    2016-01-01

    A numerical model of plasma transport and electromagnetic field in the J-PARC (Japan Proton Accelerator Research Complex) radio frequency ion source has been developed to understand the relation between antenna coil heat loadings and plasma production/transport processes. From the calculation, the local plasma density increase is observed in the region close to the antenna coil. Electrons are magnetized by the magnetic field line with absolute magnetic flux density 30-120 Gauss which leads to high local ionization rate. The results suggest that modification of magnetic configuration can be made to reduce plasma heat flux onto the antenna.

  15. Qualification Program of Korea Heat Load Test Facility KoHLT-EB for ITER Plasma Facing Components

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Suk-Kwon; Park, Seoung Dae; Jin, Hyung Gon; Lee, Eo Hwak; Yoon, Jae-Sung; Lee, Dong Won [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Cho, Seungyon [National Fusion Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    The qualification tests were performed to evaluate the high heat flux test facility for the PFCs and fusion reactor materials. For the thermal fatigue test, two types of tungsten mock-ups were fabricated. The cooling performance was tested under the similar operation condition of ITER and fusion reactor. After the completion of the preliminary mockup test and facility qualification, the high heat flux test facility will assess the performance test for the various plasma facing components in fusion reactor materials. Preliminary thermo-hydraulic and performance tests were conducted using various test mockups for the plasma facing components in the high heat flux test facilities of the world. The previous heat flux tests were performed by using the graphite heater facilities in Korea. Several facilities which equipped with an electron beam as the uniform heat source were fabricated for the tokamak PFCs in the EU, Russia and US. These heat flux test facilities are utilized for a cyclic heat flux test of the PFCs. Each facility working for their own purpose in EU FZJ, US SNL, and Russia Efremov institute. For this purpose, KoHLTEB was constructed and this facility will be used for ITER TBM performance test with the small-scale and large-scale mockups, and prototype. Also, it has been used for other fusion application for developing plasma facing component (PFC) for ITER FW, tungsten divertor, and heat transfer experiment and so on under the domestic R and D program. Korea heat load test facility by using electron beam KoHLT-EB was constructed for the high heat flux test to verify the plasma facing components, including ITER TBM first wall.

  16. Comparison of the Performance of Chilled Beam with Swirl Jet and Diffuse Ceiling Air Supply: Impact of Heat Load Distribution

    DEFF Research Database (Denmark)

    Bertheussen, Bård; Mustakallio, Panu; Kosonen, Risto

    2013-01-01

    (ventilation effectiveness of 0.4) and the air flow rate had to be above minimum to safeguard the indoor air quality. The radial swirl jet of chilled beam also was not capable of creating complete mixing at high and concentrated heat load (ventilation effectiveness of 0.7)....... (L x W x H)). A window (6.5 m2) was simulated by radiant panels. Four chilled beam units were installed symmetrically on the suspended ceiling together with two exhaust vents. The diffuse ceiling inlet was made of standard perforated acoustic tiles (0.5% total degree of perforation). The room air...... temperature was controlled at 24 °C. The quality of the generated indoor environment as defined in ISO standard 7730 (2005) was assessed based on comprehensive physical measurements. The systems created Category A thermal environment in cooling situations at heat load of 50 W∙m−2 and 78 W∙m−2 (office room...

  17. Measurement of heat load density profile on acceleration grid in MeV-class negative ion accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Hiratsuka, Junichi, E-mail: hiratsuka.junichi@jaea.go.jp; Hanada, Masaya; Kojima, Atsushi; Umeda, Naotaka; Kashiwagi, Mieko; Yoshida, Masafumi; Nishikiori, Ryo; Ichikawa, Masahiro; Watanabe, Kazuhiro; Tobari, Hiroyuki [Japan Atomic Energy Agency, 801-1 Mukoyama, Naka 311-0193 (Japan); Miyamoto, Kenji [Naruto University of Education, 748 Nakashima, Takashima, Naruto-cho, Naruto-shi, Tokushima 772-8502 (Japan)

    2016-02-15

    To understand the physics of the negative ion extraction/acceleration, the heat load density profile on the acceleration grid has been firstly measured in the ITER prototype accelerator where the negative ions are accelerated to 1 MeV with five acceleration stages. In order to clarify the profile, the peripheries around the apertures on the acceleration grid were separated into thermally insulated 34 blocks with thermocouples. The spatial resolution is as low as 3 mm and small enough to measure the tail of the beam profile with a beam diameter of ∼16 mm. It was found that there were two peaks of heat load density around the aperture. These two peaks were also clarified to be caused by the intercepted negative ions and secondary electrons from detailed investigation by changing the beam optics and gas density profile. This is the first experimental result, which is useful to understand the trajectories of these particles.

  18. Experimental Investigation of Heat Transfer in Separated Flow on a Highly Loaded LP Turbine Cascade

    Science.gov (United States)

    2003-03-01

    W Q e Q c Q f c Fig. 5 Heat-rate balance of a glue-on hot-film sensor The forced convective heat flux fcQ can be determined from the heat-rate...constant in x-direction, fcQ results in: )cTw(TAhfc Q −= (10) The heat generation rate by an electrical current I of the hot- film with a resistance Rw

  19. Vehicle Exhaust Waste Heat Recovery Model with Integrated Thermal Load Leveling

    Science.gov (United States)

    2015-08-01

    finned heat pipes, a high forced convection coefficient (>250 W/m2K, the high end of the range suggested by Incropera and DeWitt20), and no...20. Incropera FP, DeWitt DP. Fundamentals of heat and mass transfer. New York (NY): Wiley; 2002. 21. Heat Pipes. Advanced Cooling Technologies, Inc

  20. Effect of Enhanced Air Temperature (extreme heat, and Load of Non-Linear Against the Use of Electric Power

    Directory of Open Access Journals (Sweden)

    I Ketut Wijaya

    2015-12-01

    Full Text Available Usage Electric power is very easy to do, because the infrastructure for connecting  already available and widely sold. Consumption electric power is not accompanied by the ability to recognize electric power. The average increase of electricity power in Bali in extreme weather reaches 10% in years 2014, so that Bali suffered power shortages and PLN as the manager of electric power to perform scheduling on of electric power usage. Scheduling is done because many people use electric power as the load  of fan and Air Conditioner exceeding the previous time. Load of fan, air conditioning, and computers including non-linear loads which can add heat on the conductor of electricity. Non-linear load and hot weather can lead to heat on conductor so  insulation damaged  and cause electrical short circuit. Data of electric power obtained through questionnaires, surveys, measurement and retrieve data from various parties. Fires that occurred in 2014, namely 109 events, 44 is  event caused by an electric short circuit (approximately 40%. Decrease power factors can cause losses of electricity and hot. Heat can cause and adds heat on the  conductor electric. The analysis showed  understanding electric power of the average  is 27,700 with value between 20 to 40. So an understanding of the electrical power away from the understand so that many errors because of the act own. Installation tool ELCB very necessary but very necessary provide counseling   of electricity to the community.

  1. An In-Depth Look at Ground Source Heat Pumps and Other Electric Loads in Two GreenMax Homes

    Energy Technology Data Exchange (ETDEWEB)

    Puttagunta, Srikanth [Consortium for Advanced Residential Buildings (CARB), Norwalk, CT (United States); Shapiro, Carl [Consortium for Advanced Residential Buildings (CARB), Norwalk, CT (United States)

    2012-04-01

    Building America research team Consortium for Advanced Residential Buildings (CARB) partnered with WPPI Energy to answer key research questions on in-field performance of ground-source heat pumps and lighting, appliance, and miscellaneous loads (LAMELs) through extensive field monitoring at two WPPI GreenMax demonstration homes in Wisconsin. These two test home evaluations provided valuable data on the true in-field performance of various building mechanical systems and LAMELs.

  2. 集中供热系统不同调峰供热方式的技术经济性分析%Technical and Economic Analysis on Different Peak Heating Load Regulation Methods for District Heating System

    Institute of Scientific and Technical Information of China (English)

    张群力; 狄洪发

    2012-01-01

    本文主要分析了分布式调峰供热方式在集中供热系统应用中的技术经济性.通过节能性和经济性对比分析可知,相对于集中调峰供热方式,分布式调峰供热方式可以降低集中供热系统的供热能耗,提高承担基础负荷的集中热源的满负荷运行小时数、提高集中热源的供热效率,同时可以降低一次供热管网的初投资、减少一次供热管网的热损失.%In this paer,the technical and economic analysis on the district heating system with distributed peak heating load regulation method was given out. Compared with the district heating system with centralized peak heating load regulation method, the total heating energy consumption of the district heating system with distributed peak heating load regulation method was reduced. Meanwhile,the operation hours under full load condition and the heating efficiency of the centralized heating source of district heating system were increased,while the initial investiment and heat loss of the primary heating network were decreased.

  3. Influence of high temperatures and relative humidity on heat exchange of miners subjected to measured physical load

    Energy Technology Data Exchange (ETDEWEB)

    Knapik, Z.; Lyubchin' ska-Koval' ska, V.; Kozerovski, Ch.; Yuzva, V.; Tsader, Ya.; Ponerevka, E.; Paradovski, L.; Stolyarska, B.

    1987-12-01

    Investigates influence of microclimate of mines (temperature and humidity) on health of miners. Two groups of healthy men (18 to 45 and 46 to 58 years of age) performed controlled amounts of physical work on a bicycle ergometer under conditions of microclimate of mines at temperatures of 28 to 34 C and relative humidity of 100%. Increase in body heat of miners was measured by a thermocouple in the external auditory meatus 1 to 2 mm from the eardrum. Results showed a significant increase in internal temperature of body and that internal temperature of body rises with increases in external temperatures from 28 to 34 C. Conditions of test in which healthy men carry out controlled work loads significantly decrease removal of endogenous heat from body. Humidity of 100% eliminates removal of body heat by evaporation, radiation and convection. Overheating of body produces exhaustion, loss of concentration, limits diuresis and thickens urine. Miners over 45 years of age overheat more than younger men under the same conditions and work loads; men of greater body weight exhibit the same response. Tables determining approximate energy demands at the time of carrying out controlled physical work loads must take into consideration size of body, temperature of work place and relative humidity of air. 6 refs.

  4. Application of powerful quasi-steady-state plasma accelerators for simulation of ITER transient heat loads on divertor surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Tereshin, V I [Institute of Plasma Physics of the NSC KIPT, Kharkov 61108 (Ukraine); Bandura, A N [Institute of Plasma Physics of the NSC KIPT, Kharkov 61108 (Ukraine); Byrka, O V [Institute of Plasma Physics of the NSC KIPT, Kharkov 61108 (Ukraine); Chebotarev, V V [Institute of Plasma Physics of the NSC KIPT, Kharkov 61108 (Ukraine); Garkusha, I E [Institute of Plasma Physics of the NSC KIPT, Kharkov 61108 (Ukraine); Landman, I [Forschungszentrum Karlsruhe, IHM, Karlsruhe 76021 (Germany); Makhlaj, V A [Institute of Plasma Physics of the NSC KIPT, Kharkov 61108 (Ukraine); Neklyudov, I M [Institute of Plasma Physics of the NSC KIPT, Kharkov 61108 (Ukraine); Solyakov, D G [Institute of Plasma Physics of the NSC KIPT, Kharkov 61108 (Ukraine); Tsarenko, A V [Institute of Plasma Physics of the NSC KIPT, Kharkov 61108 (Ukraine)

    2007-05-15

    The paper presents the investigations of high power plasma interaction with material surfaces under conditions simulating the ITER disruptions and type I ELMs. Different materials were exposed to plasma with repetitive pulses of 250 {mu}s duration, the ion energy of up to 0.6 keV, and the heat loads varying in the 0.5-25 MJ m{sup -2} range. The plasma energy transfer to the material surface versus impact load has been analysed. The fraction of plasma energy that is absorbed by the target surface is rapidly decreased with the achievement of the evaporation onset for exposed targets. The distributions of evaporated material in front of the target surface and the thickness of the shielding layer are found to be strongly dependent on the target atomic mass. The surface analysis of tungsten targets exposed to quasi-steady-state plasma accelerators plasma streams is presented together with measurements of the melting onset load and evaporation threshold, and also of erosion patterns with increasing heat load and the number of plasma pulses.

  5. Study on Improving Partial Load by Connecting Geo-thermal Heat Pump System to Fuel Cell Network

    Science.gov (United States)

    Obara, Shinya; Kudo, Kazuhiko

    Hydrogen piping, the electric power line, and exhaust heat recovery piping of the distributed fuel cells are connected with network, and operational planning is carried out. Reduction of the efficiency in partial load is improved by operation of the geo-thermal heat pump linked to the fuel cell network. The energy demand pattern of the individual houses in Sapporo was introduced. And the analysis method aiming at minimization of the fuel rate by the genetic algorithm was described. The fuel cell network system of an analysis example assumed connecting the fuel cell co-generation of five houses. When geo-thermal heat pump was introduced into fuel cell network system stated in this paper, fuel consumption was reduced 6% rather than the conventional method

  6. A contribution to the investigation of the heat load of shock absorbers of semi-active suspensions in motor vehicles

    Directory of Open Access Journals (Sweden)

    Miroslav D. Demić

    2013-10-01

    Full Text Available Dynamic simulation, based on modeling, has a significant role during the process of vehicle development. It is especially important in the first stages of vehicle design, when relevant vehicle parameters are to be defined. Shock absorbers as executive parts of vehicle semi-active suspension systems suffer thermal loads, which may result in damage and degradation of ther characteristics. Therefore,this paper shows an attempt to analyze converting of mechanical work into heat by using the dynamic simulation method. Introduction Shock absorbers are integral elements of semi-active suspension systems for vehicles (hereinafter SASS. They directly affect the active vehicle safety. The role of shock absorbers is to absorb mechanical vibrations transferred from the road and to ensure the safety of passengers in a vehicle. The kinetic energy of vehicle vibrations transforms into mechanical work or heat in shock absorbers. In practice, in the first stage of vehicle development, the shock absorber parameters are chosen from the condition of damping vibrations of vehicles, but their thermal shock loads should be also taken into account. Motor vehicles have complex dynamic characteristics manifested by spatial movement, parameters change during operation, a number of disturbing influences, backlash, friction, hysteresis, etc. The above-mentioned dynamic phenomena, especially vibration, lead to fatigue of driver and users, reduce the life of the vehicle and its systems, etc. The main objective of the system is to reduce the reliance of the above-mentioned negative effects, improving the vehicle behavior on the road and allow the exploitation of vehicles in a wide range of service conditions. Classical systems cannot satisfiy these conditions, so there was a need to introduce new suspension systems with controlled characteristics (briefly called "semi-active", or "active" systems. Oscillatory model of vehicle The differential equations of vibratory motion of

  7. Lava heating and loading of ice sheets on early Mars: Predictions for meltwater generation, groundwater recharge, and resulting landforms

    Science.gov (United States)

    Cassanelli, James P.; Head, James W.

    2016-06-01

    Recent modeling studies of the early Mars climate predict a predominantly cold climate, characterized by the formation of regional ice sheets across the highland areas of Mars. Formation of the predicted "icy highlands" ice sheets is coincident with a peak in the volcanic flux of Mars involving the emplacement of the Late Noachian - Early Hesperian ridged plains unit. We explore the relationship between the predicted early Mars "icy highlands" ice sheets, and the extensive early flood volcanism to gain insight into the surface conditions prevalent during the Late Noachian to Early Hesperian transition period. Using Hesperia Planum as a type area, we develop an ice sheet lava heating and loading model. We quantitatively assess the thermal and melting processes involved in the lava heating and loading process following the chronological sequence of lava emplacement. We test a broad range of parameters to thoroughly constrain the lava heating and loading process and outline predictions for the formation of resulting geological features. We apply the theoretical model to a study area within the Hesperia Planum region and assess the observed geology against predictions derived from the ice sheet lava heating and loading model. Due to the highly cratered nature of the Noachian highlands terrain onto which the volcanic plains were emplaced, we predict highly asymmetrical lava loading conditions. Crater interiors are predicted to accumulate greater thicknesses of lava over more rapid timescales, while in the intercrater plains, lava accumulation occurs over longer timescales and does not reach great thicknesses. We find that top-down melting due to conductive heat transfer from supraglacial lava flows is generally limited when the emplaced lava flows are less than ∼10 m thick, but is very significant at lava flow thicknesses of ∼100 m or greater. We find that bottom-up cryosphere and ice sheet melting is most likely to occur within crater interiors where lavas

  8. Heat loads in inboard limited L-mode plasmas in TCV

    Energy Technology Data Exchange (ETDEWEB)

    Nespoli, F., E-mail: federico.nespoli@epfl.ch; Labit, B.; Furno, I.; Canal, G.P.; Fasoli, A.

    2015-08-15

    Infrared thermography is used in TCV to measure the heat flux deposited onto the graphite tiles of the inner wall. The heat flux radial profile is found to be well described by the sum of a main parallel component and a non negligible cross-field component. The latter accounts for about 20% of the deposited heat flux. The parallel component shows an enhancement around the contact point in all discharges under consideration. Main plasma parameters, such as density, current, elongation and triangularity have been varied, allowing for empirical scalings of the heat fluxes.

  9. Containment loads due to direct containment heating and associated hydrogen behavior: Analysis and calculations with the CONTAIN code

    Energy Technology Data Exchange (ETDEWEB)

    Williams, D C; Bergeron, K D; Carroll, D E; Gasser, R D; Tills, J L; Washington, K E

    1987-05-01

    One of the most important unresolved issues governing risk in many nuclear power plants involves the phenomenon called direct containment heating (DCH), in which it is postulated that molten corium ejected under high pressure from the reactor vessel is dispersed into the containment atmosphere, thereby causing sufficient heating and pressurization to threaten containment integrity. Models for the calculation of potential DCH loads have been developed and incorporated into the CONTAIN code for severe accident analysis. Using CONTAIN, DCH scenarios in PWR plants having three different representative containment types have been analyzed: Surry (subatmospheric large dry containment), Sequoyah (ice condenser containment), and Bellefonte (atmospheric large dry containment). A large number of parameter variation and phenomenological uncertainty studies were performed. Response of DCH loads to these variations was found to be quite complex; often the results differ substantially from what has been previously assumed concerning DCH. Containment compartmentalization offers the potential of greatly mitigating DCH loads relative to what might be calculated using single-cell representations of containments, but the actual degree of mitigation to be expected is sensitive to many uncertainties. Dominant uncertainties include hydrogen combustion phenomena in the extreme environments produced by DCH scenarios, and factors which affect the rate of transport of DCH energy to the upper containment. In addition, DCH loads can be aggravated by rapid blowdown of the primary system, co-dispersal of moderate quantities of water with the debris, and quenching of de-entrained debris in water; these factors act by increasing steam flows which, in turn, accelerates energy transport. It may be noted that containment-threatening loads were calculated for a substantial portion of the scenarios treated for some of the plants considered.

  10. Influence of Cooling to Heating Load Ratio on Optimal Supply Water and Air Temperatures in an Air Conditioning System

    Science.gov (United States)

    Karino, Naoki; Shiba, Takashi; Yokoyama, Ryohei; Ito, Koichi

    In planning an air conditioning system, supply water and air temperatures are important factors from the viewpoint of energy saving and cost reduction. For example, lower temperature supply water and air for space cooling reduce the coefficient of performance of a refrigeration machine, and increase the thickness of heat insulation material. However, they enable larger temperature differences, and reduce equipment sizes and power demand. It is also an important subject to evaluate the effect of the supply water and air temperatures on energy saving and cost reduction on the annual basis by considering not only cooling but also heating loads. The purposes of this paper are to propose an optimal planning method for an air conditioning system with large temperature difference, and to analyze the effect of supply water and air temperatures on the long-term economics through a numerical study for an office building. As a result, it is shown that the proposed method effectively determines supply water and air temperatures, and the influence of the cooling to heating load ratio on the long-term economics is clarified.

  11. Effect of volume loading on the Frank-Starling relation during reductions in central blood volume in heat-stressed humans

    DEFF Research Database (Denmark)

    Bundgaard-Nielsen, Morten; Wilson, T E; Seifert, Thomas

    2010-01-01

    During reductions in central blood volume while heat stressed, a greater decrease in stroke volume (SV) for a similar decrease in ventricular filling pressure, compared to normothermia, suggests that the heart is operating on a steeper portion of a Frank-Starling curve. If so, volume loading...... of heat-stressed individuals would shift the operating point to a flatter portion of the heat stress Frank-Starling curve thereby attenuating the reduction in SV during subsequent decreases in central blood volume. To investigate this hypothesis, right heart catheterization was performed in eight males.......06). However, subsequent volume loading increased SV to 143 +/- 29 ml (P = 0.003). LBNP provoked a larger decrease in SV relative to the decrease in PCWP during heating (8.6 +/- 1.9 ml mmHg(1)) compared to normothermia (4.5 +/- 3.0 ml mmHg(1), P = 0.02). After volume loading while heat stressed, the reduction...

  12. Displacement analysis of a bend plate test with mechanical loading and laser heating

    Energy Technology Data Exchange (ETDEWEB)

    Lam, P.S.

    1997-09-01

    The surface displacment of a steel plate caused by a permanent deformation as a result of local yielding was modeled by a finite element analysis. The local yielding occurs when a small area of the plate is heated by a laser beam. The calculated displacments are in good agreement with the preliminary experimental data obtained using a bend specimen with laser heating at the University of Alabama at Huntsville. It has been shown computuationally and optically that the relative displacments are less than 1mm near the laser heated area of the specimen. The results demonstrate that the experimental approach is a feasible technique for determining the residual stress under multiaxial stress field.

  13. Impact of Urban Heat Island under the Hanoi Master Plan 2030 on Cooling Loads in Residential Buildings

    Directory of Open Access Journals (Sweden)

    Tran Hoang Hai Nam

    2015-01-01

    Full Text Available This study aims to evaluate the influence of urban heat island (UHI under the Hanoi Master Plan 2030 on the energy consumption for space cooling in residential buildings. The weather conditions under the current and future status (master plan condition simulated in the previous study (Trihamdani et al., 2014 were used and cooling loads in all the residential buildings in Hanoi over the hottest month were estimated under the simulated current and future conditions by using the building simulation program, TRNSYS (v17. Three most typical housing types in the city were selected for the simulation. The cooling loads of respective housing types were obtained in each of the districts in Hanoi. The results show that the total cooling loads over June 2010 is approximately 683 Terajoule (TJ under the current status, but it is predicted to increase to 903 TJ under the master plan condition. The increment is largely due to the increase in number of households (203 TJ or 92%, but partially due to the increase in urban temperature, i.e. UHI effect (17 TJ or 8%. The increments in new built-up areas were found to be larger than those in existing built-up areas. The cooling load in apartment is approximately half of that in detached house, which is approximately half of that in row house. Moreover, it was seen that although sensible cooling loads increased with the increase in outdoor temperature, the latent cooling loads decreased due to the decrease in absolute humidity and the increase in air temperature.

  14. Inauguration of Proton Synchrotron

    CERN Multimedia

    1960-01-01

    On 5 February 1960, the Proton Synchrotron (PS) was formally inaugurated. The great Danish physicist, Niels Bohr, releases a bottle of champagne against a shielding block to launch the PS on its voyage in physics.

  15. Structural response of transient heat loading on a molybdenum surface exposed to low-energy helium ion irradiation

    Science.gov (United States)

    Sinclair, G.; Tripathi, J. K.; Diwakar, P. K.; Hassanein, A.

    2016-03-01

    The advancement of fusion reactor engineering is currently inhibited by the lack of knowledge surrounding the stability of plasma facing components (PFCs) in a tokamak environment. During normal operation, events of high heat loading occur periodically where large amounts of energy are imparted onto the PFC surface. Concurrently, irradiation by low-energy helium ions present in the fusion plasma can result in the synthesis of a fibre form nanostructure on the PFC surface, called ‘fuzz’. In order to understand how this heterogeneous structure evolves and deforms in response to transient heat loading, a pulsed Nd:YAG millisecond laser is used to simulate these events on a fuzz form molybdenum (Mo) surface. Performance was analysed by three metrics: nanostructure evolution, particle emission, and improvement in optical properties. Experiments performed at the upper end of the expected range for type-I edge-localized modes (ELMs) found that the helium-induced nanostructure completely disappears after 200 pulses of the laser at 1.5 MJ m-2. In situ mass loss measurements found that the amount of particles leaving the surface increases as energy density increases and the rate of emission increases with pulse count. Finally, optical properties assisted in providing a qualitative indication of fuzz density on the Mo surface; after 400 pulses at 1.5 MJ m-2, the optical reflectivity of the damaged surface is ~90% of that of a mirror polished Mo sample. These findings provide different results than previous studies done with tungsten (W), and further help illustrate the complicated nature of how transient events of high heat loading in a tokamak environment might impact the performance and lifetime of PFCs in ITER and future DEMO devices (Ueda et al 2014 Fusion Eng. Des. 89 901-6).

  16. Divertor heat load in ASDEX Upgrade L-mode in presence of external magnetic perturbation

    Science.gov (United States)

    Faitsch, M.; Sieglin, B.; Eich, T.; Herrmann, A.; Suttrop, W.; the ASDEX Upgrade Team

    2017-09-01

    Power exhaust is one of the major challenges for a future fusion device. Applying a non-axisymmetric external magnetic perturbation is one technique that is studied in order to mitigate or suppress large edge localized modes which accompany the high confinement regime in tokamaks. The external magnetic perturbation induces breaking in the axisymmetry of a tokamak and leads to a 2D heat flux pattern on the divertor target. The 2D heat flux pattern at the outer divertor target is studied on ASDEX Upgrade in stationary L-mode discharges. The amplitude of the 2D characteristic of the heat flux depends on the alignment between the field lines at the edge and the vacuum response of the applied magnetic perturbation spectrum. The 2D characteristic reduces with increasing density. The increasing divertor broadening, S, with increasing density is proposed as the main actuator. This is supported by a generic model using field line tracing and the vacuum field approach that is in quantitative agreement with the measured heat flux. The perturbed heat flux, averaged over a full toroidal rotation of the magnetic perturbation, is identical to the non-perturbed heat flux without magnetic perturbation. The transport qualifiers, power fall-off length {λ }q and divertor broadening, S, are the same within the uncertainty compared to the unperturbed reference. No additional cross field transport is observed.

  17. Optimization of the RF cavity heat load and trip rates for CEBAF at 12 GeV

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, He [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Roblin, Yves R. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Freyberger, Arne P. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Krafft, Geoffrey A. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Terzic, Balsa P. [Old Dominion Univ., Norfolk, VA (United States)

    2017-05-01

    The Continuous Electron Beam Accelerator Facility at JLab has 200 RF cavities in the north linac and the south linac respectively after the 12 GeV upgrade. The purpose of this work is to simultaneously optimize the heat load and the trip rate for the cavities and to reconstruct the pareto-optimal front in a timely manner when some of the cavities are turned down. By choosing an efficient optimizer and strategically creating the initial gradients, the pareto-optimal front for no more than 15 cavities down can be re-established within 20 seconds.

  18. The updated algorithm of the Energy Consumption Program (ECP): A computer model simulating heating and cooling energy loads in buildings

    Science.gov (United States)

    Lansing, F. L.; Strain, D. M.; Chai, V. W.; Higgins, S.

    1979-01-01

    The energy Comsumption Computer Program was developed to simulate building heating and cooling loads and compute thermal and electric energy consumption and cost. This article reports on the new additional algorithms and modifications made in an effort to widen the areas of application. The program structure was rewritten accordingly to refine and advance the building model and to further reduce the processing time and cost. The program is noted for its very low cost and ease of use compared to other available codes. The accuracy of computations is not sacrificed however, since the results are expected to lie within + or - 10% of actual energy meter readings.

  19. Damage prediction of carbon fibre composite armoured actively cooled plasma-facing components under cycling heat loads

    Energy Technology Data Exchange (ETDEWEB)

    Chevet, G; Schlosser, J; Courtois, X; Escourbiac, F; Missirlian, M [CEA, IRFM, F-13108 Saint Paul Lez Durance (France); Herb, V; Martin, E; Camus, G [LCTS, CNRS UMR 5801, Universite Bordeaux 1, Pessac (France); Braccini, M [SIMaP, CNRS UMR 5266, Grenoble (France)], E-mail: gaelle.chevet@cea.fr

    2009-12-15

    In order to predict the lifetime of carbon fibre composite (CFC) armoured plasma-facing components in magnetic fusion devices, it is necessary to analyse the damage mechanisms and to model the damage propagation under cycling heat loads. At Tore Supra studies have been launched to better understand the damage process of the armoured flat tile elements of the actively cooled toroidal pump limiter, leading to the characterization of the damageable mechanical behaviour of the used N11 CFC material and of the CFC/Cu bond. Up until now the calculations have shown damage developing in the CFC (within the zone submitted to high shear stress) and in the bond (from the free edge of the CFC/Cu interface). Damage is due to manufacturing shear stresses and does not evolve under heat due to stress relaxation. For the ITER divertor, NB31 material has been characterized and the characterization of NB41 is in progress. Finite element calculations show again the development of CFC damage in the high shear stress zones after manufacturing. Stresses also decrease under heat flux so the damage does not evolve. The characterization of the CFC/Cu bond is more complex due to the monoblock geometry, which leads to more scattered stresses. These calculations allow the fabrication difficulties to be better understood and will help to analyse future high heat flux tests on various mock-ups.

  20. Load Prediction in District Heating Systems with Regard to Scenarios and Uncertainties in Weather; Lastprognoser foer fjaerrvaerme med haensyn till scenarier och osaekerheter i vaedret

    Energy Technology Data Exchange (ETDEWEB)

    Hedberg, Martin; Koppers, Gijs [Meteopolaris AB, Nacka (Sweden)

    2011-11-15

    The report shows, by means of load calculations on ensemble weather forecasts and subsequent production planning, that by a better optimization of the operation of district heating plants the costs of production of heat and electricity can be reduced. During a fifth of the time the saving potential is 5% or more.

  1. Vibration measurements of high-heat-load monochromators for DESY PETRA III extension

    Energy Technology Data Exchange (ETDEWEB)

    Kristiansen, Paw, E-mail: paw.kristiansen@fmb-oxford.com [FMB Oxford Ltd, Unit 1 Ferry Mills, Oxford OX2 0ES (United Kingdom); Horbach, Jan; Döhrmann, Ralph; Heuer, Joachim [DESY, Deutsches Elektronen-Synchrotron Hamburg, Notkestrasse 85, 22607 Hamburg (Germany)

    2015-05-09

    Vibration measurements of a cryocooled double-crystal monochromator are presented. The origins of the vibrations are identified. The minimum achieved vibration of the relative pitch between the two crystals is 48 nrad RMS and the minimum achieved absolute vibration of the second crystal is 82 nrad RMS. The requirement for vibrational stability of beamline optics continues to evolve rapidly to comply with the demands created by the improved brilliance of the third-generation low-emittance storage rings around the world. The challenge is to quantify the performance of the instrument before it is installed at the beamline. In this article, measurement techniques are presented that directly and accurately measure (i) the relative vibration between the two crystals of a double-crystal monochromator (DCM) and (ii) the absolute vibration of the second-crystal cage of a DCM. Excluding a synchrotron beam, the measurements are conducted under in situ conditions, connected to a liquid-nitrogen cryocooler. The investigated DCM utilizes a direct-drive (no gearing) goniometer for the Bragg rotation. The main causes of the DCM vibration are found to be the servoing of the direct-drive goniometer and the flexibility in the crystal cage motion stages. It is found that the investigated DCM can offer relative pitch vibration down to 48 nrad RMS (capacitive sensors, 0–5 kHz bandwidth) and absolute pitch vibration down to 82 nrad RMS (laser interferometer, 0–50 kHz bandwidth), with the Bragg axis brake engaged.

  2. Vibration measurements of high-heat-load monochromators for DESY PETRA III extension

    Science.gov (United States)

    Kristiansen, Paw; Horbach, Jan; Döhrmann, Ralph; Heuer, Joachim

    2015-01-01

    The requirement for vibrational stability of beamline optics continues to evolve rapidly to comply with the demands created by the improved brilliance of the third-generation low-emittance storage rings around the world. The challenge is to quantify the performance of the instrument before it is installed at the beamline. In this article, measurement techniques are presented that directly and accurately measure (i) the relative vibration between the two crystals of a double-crystal monochromator (DCM) and (ii) the absolute vibration of the second-crystal cage of a DCM. Excluding a synchrotron beam, the measurements are conducted under in situ conditions, connected to a liquid-nitrogen cryocooler. The investigated DCM utilizes a direct-drive (no gearing) goniometer for the Bragg rotation. The main causes of the DCM vibration are found to be the servoing of the direct-drive goniometer and the flexibility in the crystal cage motion stages. It is found that the investigated DCM can offer relative pitch vibration down to 48 nrad RMS (capacitive sensors, 0–5 kHz bandwidth) and absolute pitch vibration down to 82 nrad RMS (laser interferometer, 0–50 kHz bandwidth), with the Bragg axis brake engaged. PMID:26134790

  3. An Electrothermal Plasma Source Developed for Simulation of Transient Heat Loads in Future Large Fusion Devices

    Science.gov (United States)

    Gebhart, Trey; Baylor, Larry; Winfrey, Leigh

    2016-10-01

    The realization of fusion energy requires materials that can withstand high heat and particle fluxes at the plasma material interface. In this work, an electrothermal (ET) plasma source has been designed as a possible transient heat flux source for a linear plasma material interaction device. An ET plasma source operates in the ablative arc regime, which is driven by a DC capacitive discharge. The current travels through the 4mm bore of a boron nitride liner and subsequently ablates and ionizes the liner material. This results in a high density plasma with a large unidirectional bulk flow out of the source exit. The pulse length for the ET source has been optimized using a pulse forming network to have a duration of 1ms at full-width half maximum. The peak currents and maximum source energies seen in this system are 2kA and 5kJ. The goal of this work is to show that the ET source produces electron densities and heat fluxes that are comparable to transient events in future large magnetic confinement fusion devices. Heat flux, plasma temperature, and plasma density were determined for each test shot using infrared imaging and optical spectroscopy techniques. This work will compare the ET source output (heat flux, temperature, and density) with and without an applied magnetic field. Research sponsored by the Laboratory Directed Research and Development Program of Oak Ridge National Laboratory, managed by UT-Battelle, LLC, for the U. S. Department of Energy.

  4. Heat pumps: impact of the partial load operation on the efficiency; Pompes a chaleur: impact du fonctionnement a charge partielle sur le rendement

    Energy Technology Data Exchange (ETDEWEB)

    Bernier, J. [Climastar, 35 - Vitre (France)

    2002-10-01

    On site measurements have permitted to demonstrate the energy loss generated by the rise of rate of heat pumps. The aim of this article is to propose a method for the calculation of the effective power a heat pump with respect to the duration of the operation cycle. The effective power varies with the thermal inertia of the heat emitter, with the regulation, with the size of the pump and with its load ratio. (J.S.)

  5. Artificial Neural Networks: a viable tool to design heat load smoothing strategies for the ITER Toroidal Field coils

    Science.gov (United States)

    Froio, A.; Bonifetto, R.; Carli, S.; Quartararo, A.; Savoldi, L.; Zanino, R.

    2015-12-01

    In superconducting tokamaks, cryoplants provide the helium needed to cool the superconducting magnet systems. The evaluation of the heat load from the magnets to the cryoplant is fundamental for the design of the latter and the assessment of suitable strategies to smooth the heat load pulses induced by the pulsed plasma scenarios is crucial for the operation. Here, a simplified thermal-hydraulic model of an ITER Toroidal Field (TF) magnet, based on Artificial Neural Networks (ANNs), is developed and inserted into a detailed model of the ITER TF winding and casing cooling circuits based on the state-of-the-art 4C code, which also includes active controls. The low computational effort requested by such a model allows performing a fast parametric study, to identify the best smoothing strategy during standard plasma operation. The ANNs are trained using 4C simulations, and the predictive capabilities of the simplified model are assessed against 4C simulations, both with and without active smoothing, in terms of accuracy and computational time.

  6. The Effect of Thermal Mass on Annual Heat Load and Thermal Comfort in Cold Climate Construction

    DEFF Research Database (Denmark)

    Stevens, Vanessa; Kotol, Martin; Grunau, Bruno

    2016-01-01

    Thermal mass in building construction refers to a building material's ability to absorb and release heat based on changing environmental conditions. In building design, materials with high thermal mass used in climates with a diurnal temperature swing around the interior set-point temperature hav...

  7. Future Synchrotron Radiation Sources

    CERN Document Server

    Winick, Herman

    2003-01-01

    Sources of synchrotron radiation (also called synchrotron light) and their associated research facilities have experienced a spectacular growth in number, performance, and breadth of application in the past two to three decades. In 1978 there were eleven electron storage rings used as light sources. Three of these were small rings, all below 500 mega-electron volts (MeV), dedicated to this purpose; the others, with energy up to 5 giga-electron volts (GeV), were used parasitically during the operation of the ring for high energy physics research. In addition, at that time synchrotron radiation from nine cyclic electron synchrotrons, with energy up to 5 GeV, was also used parasitically. At present no cyclic synchrotrons are used, while about 50 electron storage rings are in operation around the world as fully dedicated light sources for basic and applied research in a wide variety of fields. Among these fields are structural molecular biology, molecular environmental science, materials, analytic chemistry, micr...

  8. Preparation of calcium chloride-loaded solid lipid particles and heat-triggered calcium ion release

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Huangying; Kim, Jin-Chul [Kangwon National University, Chunchon (Korea, Republic of)

    2015-08-15

    CaCl{sub 2}-loaded solid lipid particles (SLPs) were prepared by a melt/emulsification/solidification method. CaCl{sub 2} microparticles (1-5 μm) could be obtained in a mortar with aid of the dispersant (Tween 80/Span80 (35/65, w/w)) when the ratio of CaCl{sub 2} to dispersant was 2 : 0.1 (w/w). SLP was prepared by dispersing 0.42 g of micronized CaCl{sub 2} particles in 2 g of molten PBSA, emulsifying the mixture at 85 .deg. C in 40 ml of Tween 20 solution (0.5% w/v), and quenching the emulsion in an ice bath. The diameter of CaCl{sub 2}-loaded SLP was 10-150 μm. The unenveloped CaCl{sub 2} could be removed by dialysis and the specific loading of CaCl{sub 2} in SLP was 0.036mg/mg. An EDS spectrum of CaCl{sub 2}-loaded SLP, which was dialyzed, showed that the unenveloped CaCl{sub 2} was completely removed. Any excipients (dispersant, Tween 20, CaCl{sub 2}) had little effect on the melting point of SLPs. No appreciable amount of Ca2+ was released in 20-50 .deg. C for 22 h. But the release degree at 60 .deg. C was significant (about 2.3%) during the same period. The matrix of the lipid particle was in a liquid state at 60 .deg. C, so CaCl{sub 2} particles could move freely and contact the surrounding water, leading to the release. At 70 .deg. C, the release degree at a given time was a few times higher than that obtained at 60 .deg. C.

  9. Air-To-Water Heat Pumps with Radiant Delivery in Low Load Homes: Tucson, Arizona and Chico, California (Fact Sheet)

    Energy Technology Data Exchange (ETDEWEB)

    2013-11-01

    Space conditioning represents nearly 50% of average residential household energy consumption, highlighting the need to identify alternative cost-effective, energy-efficient cooling and heating strategies. As homes are better built, there is an increasing need for strategies that are particularly well suited for high performance, low load homes. ARBI researchers worked with two test homes in hot-dry climates to evaluate the in-situ performance of air-to-water heat pump (AWHP) systems, an energy efficient space conditioning solution designed to cost-effectively provide comfort in homes with efficient, safe, and durable operation. Two monitoring projects of test houses in hot-dry climates were initiated in 2010 to test this system. Both systems were fully instrumented and have been monitored over one year to capture complete performance data over the cooling and heating seasons. Results are used to quantify energy savings, cost-effectiveness, and system performance using different operating modes and strategies. A calibrated TRNSYS model was developed and used to evaluate performance in various climate regions. This strategy is most effective in tight, insulated homes with high levels of thermal mass (i.e. exposed slab floors).

  10. Melt layer erosion of pure and lanthanum doped tungsten under VDE-like high heat flux loads

    Science.gov (United States)

    Yuan, Y.; Greuner, H.; Böswirth, B.; Luo, G.-N.; Fu, B. Q.; Xu, H. Y.; Liu, W.

    2013-07-01

    Heat loads expected for VDEs in ITER were applied in the neutral beam facility GLADIS at IPP Garching. Several ˜3 mm thick rolled pure W and W-1 wt% La2O3 plates were exposed to pulsed hydrogen beams with a central heat flux of 23 MW/m2 for 1.5-1.8 s. The melting thresholds are determined, and melt layer motion as well as material structure evolutions are shown. The melting thresholds of the two W grades are very close in this experimental setup. Lots of big bubbles with diameters from several μm to several 10 μm in the re-solidified layer of W were observed and they spread deeper with increasing heat flux. However, for W-1 wt% La2O3, no big bubbles were found in the corrugated melt layer. The underlying mechanisms referred to the melt layer motion and bubble issues are tentatively discussed based on comparison of the erosion characteristics between the two W grades.

  11. Melt layer erosion of pure and lanthanum doped tungsten under VDE-like high heat flux loads

    Energy Technology Data Exchange (ETDEWEB)

    Yuan, Y., E-mail: yuanyue08@mails.tsinghua.edu.cn [Department of Material Science and Engineering, Tsinghua University, Haidian District, Beijing 100084 (China); Greuner, H.; Böswirth, B. [Max-Planck-Institut für Plasmaphysik, EURATOM Association, 85748 Garching (Germany); Luo, G.-N. [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui 230031 (China); Fu, B.Q.; Xu, H.Y. [Department of Material Science and Engineering, Tsinghua University, Haidian District, Beijing 100084 (China); Liu, W., E-mail: liuw@mail.tsinghua.edu.cn [Department of Material Science and Engineering, Tsinghua University, Haidian District, Beijing 100084 (China)

    2013-07-15

    Heat loads expected for VDEs in ITER were applied in the neutral beam facility GLADIS at IPP Garching. Several ∼3 mm thick rolled pure W and W–1 wt% La{sub 2}O{sub 3} plates were exposed to pulsed hydrogen beams with a central heat flux of 23 MW/m{sup 2} for 1.5–1.8 s. The melting thresholds are determined, and melt layer motion as well as material structure evolutions are shown. The melting thresholds of the two W grades are very close in this experimental setup. Lots of big bubbles with diameters from several μm to several 10 μm in the re-solidified layer of W were observed and they spread deeper with increasing heat flux. However, for W–1 wt% La{sub 2}O{sub 3}, no big bubbles were found in the corrugated melt layer. The underlying mechanisms referred to the melt layer motion and bubble issues are tentatively discussed based on comparison of the erosion characteristics between the two W grades.

  12. ITER-relevant transient heat loads on tungsten exposed to plasma and beryllium

    Science.gov (United States)

    Yu, J. H.; Doerner, R. P.; Dittmar, T.; Höschen, T.; Schwarz-Selinger, T.; Baldwin, M. J.

    2014-04-01

    Tungsten (W) is presently the most attractive plasma facing material for future fusion reactors. Off-normal transient events such as edge localized modes and disruptions are simulated with a pulsed laser system in the PISCES-B facility, providing pulses with 1-10 ms duration with absorbed heat flux factors up to ˜90 MJ m-2 s-1/2. This paper characterizes surface morphology changes and damage thresholds under transient heating on W exposed to He plasma or D plasma with and without Be coatings. W is damaged in the form of grain growth, surface roughening, melting and cracking. With a Be coating on the order of μm thick, the laser pulse produces a variety of Be surface changes including Be-W alloying, vaporization of the Be layer, melting and delamination.

  13. Numerical Analysis of a Pulse Detonation Cross Flow Heat Load Experiment

    Science.gov (United States)

    Paxson, Daniel E.; Naples, Andrew .; Hoke, John L.; Schauer, Fred

    2011-01-01

    A comparison between experimentally measured and numerically simulated, time-averaged, point heat transfer rates in a pulse detonation (PDE) engine is presented. The comparison includes measurements and calculations for heat transfer to a cylinder in crossflow and to the tube wall itself using a novel spool design. Measurements are obtained at several locations and under several operating conditions. The measured and computed results are shown to be in substantial agreement, thereby validating the modeling approach. The model, which is based in computational fluid dynamics (CFD) is then used to interpret the results. A preheating of the incoming fuel charge is predicted, which results in increased volumetric flow and subsequent overfilling. The effect is validated with additional measurements.

  14. Optical systems for synchrotron radiation. Lecture 2. Mirror systems

    Energy Technology Data Exchange (ETDEWEB)

    Howells, M.R.

    1986-02-01

    The process of reflection of VUV and x-radiation is summarized. The functions of mirrors in synchrotron beamlines are described, which include deflection, filtration, power absorption, formation of a real image, focusing, and collimation. Fabrication of optical surfaces for synchrotron radiation beamlines are described, and include polishing of a near spherical surface as well as bending a cylindrical surface to toroidal shape. The imperfections present in mirrors, aberrations and surface figure inaccuracy, are discussed. Calculation of the thermal load of a mirror in a synchrotron radiation beam and the cooling of the mirror are covered briefly. 50 refs., 7 figs. (LEW)

  15. Buoyancy effects in vertical rectangular duct with coplanar magnetic field and single sided heat load

    Energy Technology Data Exchange (ETDEWEB)

    Kirillov, I.R. [NIIEFA – JSC “D.V. Efremov Institute of Electrophysical Apparatus”, St. Petersburg, 196641 (Russian Federation); Obukhov, D.M., E-mail: obukhov@sintez.niiefa.spb.su [NIIEFA – JSC “D.V. Efremov Institute of Electrophysical Apparatus”, St. Petersburg, 196641 (Russian Federation); Genin, L.G. [MPEI – National Research University “Moscow Power Engineering Institute”, 14 Krasnokazarmennaya str., Moscow (Russian Federation); Sviridov, V.G.; Razuvanov, N.G.; Batenin, V.M.; Belyaev, I.A. [JIHT – Joint Institute of High Temperatures of the Russian Academy of Science, 13/19, Igorskaya str., Moscow (Russian Federation); Poddubnyi, I.I. [MPEI – National Research University “Moscow Power Engineering Institute”, 14 Krasnokazarmennaya str., Moscow (Russian Federation); Pyatnitskaya, N.Yu. [JIHT – Joint Institute of High Temperatures of the Russian Academy of Science, 13/19, Igorskaya str., Moscow (Russian Federation)

    2016-03-15

    Highlights: • Heat transfer in vertical duct mercury flow in coplanar magnetic field is studied. • Mean velocity, temperature and temperature pulsations are measured. • Buoyancy influence on heat transfer is found. - Abstract: This article investigates an effect which was found out in downward flow of liquid metal (LM) in vertical rectangular duct in coplanar magnetic field (MF). The experiments have been performed on facility which located in JIHT. This facility is magneto hydrodynamic (MHD) mercury close-loop. The temperature field measurements have been performed at one side heating conditions in coplanar magnetic field. The averaged temperature fields, wall temperature distributions and statistical characteristics of temperature fluctuation have been obtained. The strong influence of counter thermo-gravitational convection (TGC) on average and fluctuation parameters has been observed. The influence of TGC in magnetic field leads to developing of temperature low-frequency fluctuations with high magnitude. The temperature fluctuation amplitude in a wide range of operating conditions is higher than turbulence level.

  16. SYNCHROTRON RADIATION SOURCES

    Energy Technology Data Exchange (ETDEWEB)

    HULBERT,S.L.; WILLIAMS,G.P.

    1998-07-01

    Synchrotron radiation is a very bright, broadband, polarized, pulsed source of light extending from the infrared to the x-ray region. It is an extremely important source of Vacuum Ultraviolet radiation. Brightness is defined as flux per unit area per unit solid angle and is normally a more important quantity than flux alone particularly in throughput limited applications which include those in which monochromators are used. It is well known from classical theory of electricity and magnetism that accelerating charges emit electromagnetic radiation. In the case of synchrotron radiation, relativistic electrons are accelerated in a circular orbit and emit electromagnetic radiation in a broad spectral range. The visible portion of this spectrum was first observed on April 24, 1947 at General Electric's Schenectady facility by Floyd Haber, a machinist working with the synchrotron team, although the first theoretical predictions were by Lienard in the latter part of the 1800's. An excellent early history with references was presented by Blewett and a history covering the development of the utilization of synchrotron radiation was presented by Hartman. Synchrotron radiation covers the entire electromagnetic spectrum from the infrared region through the visible, ultraviolet, and into the x-ray region up to energies of many 10's of kilovolts. If the charged particles are of low mass, such as electrons, and if they are traveling relativistically, the emitted radiation is very intense and highly collimated, with opening angles of the order of 1 milliradian. In electron storage rings there are three possible sources of synchrotron radiation; dipole (bending) magnets; wigglers, which act like a sequence of bending magnets with alternating polarities; and undulators, which are also multi-period alternating magnet systems but in which the beam deflections are small resulting in coherent interference of the emitted light.

  17. RF gymnastics in synchrotrons

    CERN Document Server

    Garoby, R

    2011-01-01

    The RF systems installed in synchrotrons can be used to change the longitudinal beam characteristics. 'RF gymnastics' designates manipulations of the RF parameters aimed at providing such non-trivial changes. Some keep the number of bunches constant while changing bunch length, energy spread, emittance, or distance between bunches. Others are used to change the number of bunches. After recalling the basics of longitudinal beam dynamics in a hadron synchrotron, this paper deals with the most commonly used gymnastics. Their principle is described as well as their performance and limitations.

  18. RF Gymnastics in Synchrotrons

    CERN Document Server

    Garoby, R

    2005-01-01

    The RF systems installed in synchrotrons can be used to change the longitudinal beam characteristics. "RF gymnastics" designates manipulations of the RF parameters aimed at providing such non-trivial changes. Some keep the number of bunches constant while changing bunch length, energy spread, emittance or distance between bunches. Others are used to change the number of bunches. After recalling the basics of longitudinal beam dynamics in a hadron synchrotron, this paper deals with the most commonly used gymnastics. Their principle is described as well as their performance and limitations.

  19. Compact synchrotron light sources

    CERN Document Server

    Weihreter, Ernst

    1996-01-01

    This book covers a new niche in circular accelerator design, motivated by the promising industrial prospects of recent micromanufacturing methods - X-ray lithography, synchrotron radiation-based micromachining and microanalysis techniques. It describes the basic concepts and the essential challenges for the development of compact synchrotron radiation sources from an accelerator designer's point of view and gives an outline of the actual state of the art. The volume is intended as an introduction and as a reference for physicists, engineers and managers involved in this rapidly developing fiel

  20. Beam loading

    CERN Document Server

    Gamp, Alexander

    2013-01-01

    We begin by giving a description of the radio-frequency generator-cavity-beam coupled system in terms of basic quantities. Taking beam loading and cavity detuning into account, expressions for the cavity impedance as seen by the generator and as seen by the beam are derived. Subsequently methods of beam-loading compensation by cavity detuning, radio-frequency feedback and feedforward are described. Examples of digital radio-frequency phase and amplitude control for the special case of superconducting cavities are also given. Finally, a dedicated phase loop for damping synchrotron oscillations is discussed.

  1. Experimental study of ELM-like heat loading on beryllium under ITER operational conditions

    Science.gov (United States)

    Spilker, B.; Linke, J.; Pintsuk, G.; Wirtz, M.

    2016-02-01

    The experimental fusion reactor ITER, currently under construction in Cadarache, France, is transferring the nuclear fusion research to the power plant scale. ITER’s first wall (FW), armoured by beryllium, is subjected to high steady state and transient power loads. Transient events like edge localized modes not only deposit power densities of up to 1.0 GW m-2 for 0.2-0.5 ms in the divertor of the machine, but also affect the FW to a considerable extent. Therefore, a detailed study was performed, in which transient power loads with absorbed power densities of up to 1.0 GW m-2 were applied by the electron beam facility JUDITH 1 on beryllium specimens at base temperatures of up to 300 °C. The induced damage was evaluated by means of scanning electron microscopy and laser profilometry. As a result, the observed damage was highly dependent on the base temperatures and absorbed power densities. In addition, five different classes of damage, ranging from ‘no damage’ to ‘crack network plus melting’, were defined and used to locate the damage, cracking, and melting thresholds within the tested parameter space.

  2. Heat loads of transparent construction elements and sun shading systems; Waermelasten transparenter Bauteile und Sonnenschutzsysteme

    Energy Technology Data Exchange (ETDEWEB)

    Simmler, H.; Binder, B.; Vonbank, R.

    2000-07-01

    This report for the Swiss Federal Office of Energy (SFOE) describes a test system installed at the Swiss Federal Laboratories for Materials Testing and Research (EMPA) in Duebendorf, Switzerland, for the investigation of heat gain by glazing elements often used in modern architecture and the efficiency of shading elements. The two climatically controlled test cells for the measurement of the thermal characteristics of facade elements and shading systems are described and the results of measurements made using various types of glazing and shading systems - including external and internal lamellas, blinds and extendible fabric sunshades - are presented. The results are analysed and interpreted in a comprehensive appendix.

  3. Plant-based food and feed protein structure changes induced by gene-transformation, heating and bio-ethanol processing: a synchrotron-based molecular structure and nutrition research program.

    Science.gov (United States)

    Yu, Peiqiang

    2010-11-01

    Unlike traditional "wet" analytical methods which during processing for analysis often result in destruction or alteration of the intrinsic protein structures, advanced synchrotron radiation-based Fourier transform infrared microspectroscopy has been developed as a rapid and nondestructive and bioanalytical technique. This cutting-edge synchrotron-based bioanalytical technology, taking advantages of synchrotron light brightness (million times brighter than sun), is capable of exploring the molecular chemistry or structure of a biological tissue without destruction inherent structures at ultra-spatial resolutions. In this article, a novel approach is introduced to show the potential of the advanced synchrotron-based analytical technology, which can be used to study plant-based food or feed protein molecular structure in relation to nutrient utilization and availability. Recent progress was reported on using synchrotron-based bioanalytical technique synchrotron radiation-based Fourier transform infrared microspectroscopy and diffused reflectance infrared Fourier transform spectroscopy to detect the effects of gene-transformation (Application 1), autoclaving (Application 2), and bio-ethanol processing (Application 3) on plant-based food and feed protein structure changes on a molecular basis. The synchrotron-based technology provides a new approach for plant-based protein structure research at ultra-spatial resolutions at cellular and molecular levels.

  4. High-heat-load monochromator options for the RIXS beamline at the APS with the MBA lattice

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Zunping, E-mail: zpliu@anl.gov; Gog, Thomas, E-mail: gog@aps.anl.gov; Stoupin, Stanislav A.; Upton, Mary H.; Ding, Yang; Kim, Jung-Ho; Casa, Diego M.; Said, Ayman H.; Carter, Jason A.; Navrotski, Gary [Advanced Photon Source, Argonne National Laboratory, 9700 S. Cass Ave, Lemont, IL 60439 (United States)

    2016-07-27

    With the MBA lattice for APS-Upgrade, tuning curves of 2.6 cm period undulators meet the source requirements for the RIXS beamline. The high-heat-load monochromator (HHLM) is the first optical white beam component. There are four options for the HHLM such as diamond monochromators with refrigerant of either water or liquid nitrogen (LN{sub 2}), and silicon monochromators of either direct or indirect cooling system. Their performances are evaluated at energy 11.215 keV (Ir L-III edge). The cryo-cooled diamond monochromator has similar performance as the water-cooled diamond monochromator because GaIn of the Cu-GaIn-diamond interface becomes solid. The cryo-cooled silicon monochromators perform better, not only in terms of surface slope error due to thermal deformation, but also in terms of thermal capacity.

  5. Estimation of the dust production rate from the tungsten armour after repetitive ELM-like heat loads

    Science.gov (United States)

    Pestchanyi, S.; Garkusha, I.; Makhlaj, V.; Landman, I.

    2011-12-01

    Experimental simulations for the erosion rate of tungsten targets under ITER edge-localized mode (ELM)-like surface heat loads of 0.75 MJ m-2 causing surface melting and of 0.45 MJ m-2 without melting have been performed in the QSPA-Kh50 plasma accelerator. Analytical considerations allow us to conclude that for both energy deposition values the erosion mechanism is solid dust ejection during surface cracking under the action of thermo-stress. Tungsten influx into the ITER containment of NW~5×1018 W per medium size ELM of 0.75 MJ m-2 and 0.25 ms time duration has been estimated. The radiation cooling power of Prad=150-300 MW due to such influx of tungsten is intolerable: it should cool the ITER core to 1 keV within a few seconds.

  6. Mitigation of upward and downward vertical displacement event heat loads with upper or lower massive gas injection in DIII-D

    Energy Technology Data Exchange (ETDEWEB)

    Hollmann, E. M.; Moyer, R. A. [University of California-San Diego, La Jolla, California 92093 (United States); Commaux, N.; Shiraki, D. [Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831 (United States); Eidietis, N. W.; Parks, P. B. [General Atomics, San Diego, California 92186 (United States); Lasnier, C. J. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States)

    2015-10-15

    Intentionally triggered upward and downward vertical displacement events (VDEs) leading to disruptions were pre-emptively mitigated with neon massive gas injection (MGI) coming from either above or below the plasma. Global indicators of disruption mitigation effectiveness (conducted heat loads, radiated power, and vessel motion) do not show a clear improvement when mitigating with the gas jet located closer to the VDE impact area. A clear trend of improved mitigation is observed for earlier MGI timing relative to the VDE impact time. The plasma edge magnetic perturbation is seen to lock to a preferential phase during the VDE thermal quench, but this phase is not clearly matched by preliminary attempts to fit to the conducted heat load phase. Clear indications of plasma infra-red (IR) emission are observed both before and during the disruptions. This IR emission can affect calculation of disruption heat loads; here, the time decay of post-disruption IR signals is used to correct for this effect.

  7. Mitigation of upward and downward vertical displacement event heat loads with upper or lower massive gas injection in DIII-D

    Science.gov (United States)

    Hollmann, E. M.; Commaux, N.; Eidietis, N. W.; Lasnier, C. J.; Moyer, R. A.; Parks, P. B.; Shiraki, D.

    2015-10-01

    Intentionally triggered upward and downward vertical displacement events (VDEs) leading to disruptions were pre-emptively mitigated with neon massive gas injection (MGI) coming from either above or below the plasma. Global indicators of disruption mitigation effectiveness (conducted heat loads, radiated power, and vessel motion) do not show a clear improvement when mitigating with the gas jet located closer to the VDE impact area. A clear trend of improved mitigation is observed for earlier MGI timing relative to the VDE impact time. The plasma edge magnetic perturbation is seen to lock to a preferential phase during the VDE thermal quench, but this phase is not clearly matched by preliminary attempts to fit to the conducted heat load phase. Clear indications of plasma infra-red (IR) emission are observed both before and during the disruptions. This IR emission can affect calculation of disruption heat loads; here, the time decay of post-disruption IR signals is used to correct for this effect.

  8. Synchrotron radiation in biosciences

    Science.gov (United States)

    Marinkovic, Nebojsa S.; Gupta, Sayan; Zhan, Chenyang; Chance, Mark R.

    2005-12-01

    The Center for Synchrotron Biosciences (CSB) operates five beamlines at the National Synchrotron Light Source (NSLS). Infrared (IR) micro-spectroscopy, X-ray absorption spectroscopy, structural proteomics and macromolecular footprinting are among the major technologies available through the Center. IR micro-spectroscopy is used to examine protein-folding in the microsecond time regime, image bone, neurons, seeds and other biological tissues, as well as image samples of interest in the chemical and environmental sciences. Structural proteomics research of New York Structural Genomics Research Consortium (NYSGRC) is steadily increasing the number of solved protein structures, with a goal to solve 100-200 structures per year. To speed up the research, a high-throughput method called 'metallomics' was implemented for NYSGRC crystallographers to detect intrinsic anomalous scatterers using X-ray absorption spectroscopy. Hydroxyl radical mediated X-ray footprinting is capable of resolving folding events of RNA, at single base resolution on millisecond timescales using a synchrotron white beam. The high brightness of synchrotron source is essential for CSB projects as it permits the use of smaller sample sizes and/or concentration, and allows studies of more complicated biological systems than with conventional sources.

  9. Synchrotron radiation in biosciences

    Energy Technology Data Exchange (ETDEWEB)

    Marinkovic, Nebojsa S. [Center for Synchrotron Biosciences, Albert Einstein College of Medicine, 1300 Morris Park Avenue, Ullman 315, Bronx, NY 10461 (United States)]. E-mail: marinkov@bnl.gov; Gupta, Sayan [Center for Synchrotron Biosciences, Albert Einstein College of Medicine, 1300 Morris Park Avenue, Ullman 315, Bronx, NY 10461 (United States); Zhan, Chenyang [Center for Synchrotron Biosciences, Albert Einstein College of Medicine, 1300 Morris Park Avenue, Ullman 315, Bronx, NY 10461 (United States); Chance, Mark R. [Center for Synchrotron Biosciences, Albert Einstein College of Medicine, 1300 Morris Park Avenue, Ullman 315, Bronx, NY 10461 (United States)

    2005-12-15

    The Center for Synchrotron Biosciences (CSB) operates five beamlines at the National Synchrotron Light Source (NSLS). Infrared (IR) micro-spectroscopy, X-ray absorption spectroscopy, structural proteomics and macromolecular footprinting are among the major technologies available through the Center. IR micro-spectroscopy is used to examine protein-folding in the microsecond time regime, image bone, neurons, seeds and other biological tissues, as well as image samples of interest in the chemical and environmental sciences. Structural proteomics research of New York Structural Genomics Research Consortium (NYSGRC) is steadily increasing the number of solved protein structures, with a goal to solve 100-200 structures per year. To speed up the research, a high-throughput method called 'metallomics' was implemented for NYSGRC crystallographers to detect intrinsic anomalous scatterers using X-ray absorption spectroscopy. Hydroxyl radical mediated X-ray footprinting is capable of resolving folding events of RNA, at single base resolution on millisecond timescales using a synchrotron white beam. The high brightness of synchrotron source is essential for CSB projects as it permits the use of smaller sample sizes and/or concentration, and allows studies of more complicated biological systems than with conventional sources.

  10. Comparative study of beam losses and heat loads reduction methods in MITICA beam source

    Energy Technology Data Exchange (ETDEWEB)

    Sartori, E., E-mail: emanuele.sartori@igi.cnr.it; Agostinetti, P.; Dal Bello, S.; Marcuzzi, D.; Serianni, G.; Veltri, P. [Consorzio RFX, Euratom-ENEA association, C.so Stati Uniti 4, 35127 Padova (Italy); Sonato, P. [Consorzio RFX, Euratom-ENEA association, C.so Stati Uniti 4, 35127 Padova (Italy); Dipartimento di Ingegneria Elettrica, Padova University, Via Gradenigo 6/a, 35131 Padova (Italy)

    2014-02-15

    In negative ion electrostatic accelerators a considerable fraction of extracted ions is lost by collision processes causing efficiency loss and heat deposition over the components. Stripping is proportional to the local density of gas, which is steadily injected in the plasma source; its pumping from the extraction and acceleration stages is a key functionality for the prototype of the ITER Neutral Beam Injector, and it can be simulated with the 3D code AVOCADO. Different geometric solutions were tested aiming at the reduction of the gas density. The parameter space considered is limited by constraints given by optics, aiming, voltage holding, beam uniformity, and mechanical feasibility. The guidelines of the optimization process are presented together with the proposed solutions and the results of numerical simulations.

  11. Comparative study of beam losses and heat loads reduction methods in MITICA beam source

    Science.gov (United States)

    Sartori, E.; Agostinetti, P.; Dal Bello, S.; Marcuzzi, D.; Serianni, G.; Sonato, P.; Veltri, P.

    2014-02-01

    In negative ion electrostatic accelerators a considerable fraction of extracted ions is lost by collision processes causing efficiency loss and heat deposition over the components. Stripping is proportional to the local density of gas, which is steadily injected in the plasma source; its pumping from the extraction and acceleration stages is a key functionality for the prototype of the ITER Neutral Beam Injector, and it can be simulated with the 3D code AVOCADO. Different geometric solutions were tested aiming at the reduction of the gas density. The parameter space considered is limited by constraints given by optics, aiming, voltage holding, beam uniformity, and mechanical feasibility. The guidelines of the optimization process are presented together with the proposed solutions and the results of numerical simulations.

  12. Researching Complex Heat, Air and Moisture Interactions for a Wide-Range of Building Envelope Systems and Environmental Loads

    Energy Technology Data Exchange (ETDEWEB)

    Karagiozis, A.N.

    2007-05-15

    This document serves as the final report documenting work completed by Oak Ridge National Laboratory (ORNL) and the Fraunhofer Institute in Building Physics (Holzkirchen, Germany) under an international CRADA No. 0575 with Fraunhofer Institute of Bauphysics of the Federal Republic of Germany for Researching Complex Heat, Air and Moisture Interactions for a Wide Range of Building Envelope Systems and Environmental Loads. This CRADA required a multi-faceted approach to building envelope research that included a moisture engineering approach by blending extensive material property analysis, laboratory system and sub-system thermal and moisture testing, and advanced moisture analysis prediction performance. The Participant's Institute for Building physics (IBP) and the Contractor's Buildings Technology Center (BTC) identified potential research projects and activities capable of accelerating and advancing the development of innovative, low energy and durable building envelope systems in diverse climates. This allowed a major leverage of the limited resources available to ORNL to execute the required Department of Energy (DOE) directives in the area of moisture engineering. A joint working group (ORNL and Fraunhofer IBP) was assembled and a research plan was executed from May 2000 to May 2005. A number of key deliverables were produced such as adoption of North American loading into the WUFI-software. in addition the ORNL Weather File Analyzer was created and this has been used to address environmental loading for a variety of US climates. At least 4 papers have been co-written with the CRADA partners, and a chapter in the ASTM Manual 40 on Moisture Analysis and Condensation Control. All deliverables and goals were met and exceeded making this collaboration a success to all parties involves.

  13. The Synchrotron Radiation for Steel Research

    Directory of Open Access Journals (Sweden)

    Piyada Suwanpinij

    2016-01-01

    Full Text Available The synchrotron X-ray radiation is a great tool in materials characterization with several advantageous features. The high intensity allows clear interaction signals and high energy of X-ray yields higher sampling volume. The samples do not need extra preparation and the microstructure is therefore not affected. With the tunability of the X-ray energy, a large range of elements and features in the samples can be investigated by different techniques, which is a significant difference between a stand-alone X-ray tube and synchrotron X-ray. Moreover, any experimental equipment can be installed through which the synchrotron beam travels. This facilitates the so-called in situ characterization such as during heat treatment, hot deformation, chemical reaction or welding. Although steel which possesses rather high density requires very high energy X-ray for large interaction volume, lower energy is still effective for the investigation of local structure of nanoconstituents. This work picks up a couple examples employing synchrotron X-ray for the characterization of high strength steels. The first case is the quantification of precipitates in high strength low alloyed (HSLA steel by X-ray absorption spectroscopy. The other case is the in situ X-ray diffraction for phase fraction and carbon partitioning in multiphase steels such as transformation induced plasticity (TRIP steel.

  14. Evolution of transiently melt damaged tungsten under ITER-relevant divertor plasma heat loading

    Energy Technology Data Exchange (ETDEWEB)

    Bardin, S., E-mail: s.bardin@differ.nl [FOM Institute DIFFER – Dutch Institute For Fundamental Energy Research, Ass EURATOM-FOM, Trilateral Euregio Cluster, Nieuwegein (Netherlands); Morgan, T.W. [FOM Institute DIFFER – Dutch Institute For Fundamental Energy Research, Ass EURATOM-FOM, Trilateral Euregio Cluster, Nieuwegein (Netherlands); Glad, X. [Université de Lorraine, Institut Jean Lamour, Vandoeuvre-les-Nancy (France); Pitts, R.A. [ITER Organization, CS 90 046, 13067 St Paul Lez Durance Cedex (France); De Temmerman, G. [FOM Institute DIFFER – Dutch Institute For Fundamental Energy Research, Ass EURATOM-FOM, Trilateral Euregio Cluster, Nieuwegein (Netherlands); ITER Organization, CS 90 046, 13067 St Paul Lez Durance Cedex (France)

    2015-08-15

    A high-repetition-rate ELM simulation system was used at both the Pilot-PSI and Magnum-PSI linear plasma devices to investigate the nature of W damage under multiple shallow melt events and the subsequent surface evolution under ITER relevant plasma fluence and high ELM number. First, repetitive shallow melting of two W monoblocks separated by a 0.5 mm gap was obtained by combined pulsed/steady-state hydrogen plasma loading at normal incidence in the Pilot-PSI device. Surface modifications including melting, cracking and strong net-reshaping of the surface are obtained. During the second step, the pre-damaged W sample was exposed to a high flux plasma regime in the Magnum-PSI device with a grazing angle of 35°. SEM analysis indicates no measurable change to the surface state after the exposure in Magnum-PSI. An increase in transient-induced temperature rise of 40% is however observed, indicating a degradation of thermal properties over time.

  15. Variability in Heat Strain in Fully Encapsulated Impermeable Suits in Different Climates and at Different Work Loads.

    Science.gov (United States)

    DenHartog, Emiel A; Rubenstein, Candace D; Deaton, A Shawn; Bogerd, Cornelis Peter

    2017-03-01

    A major concern for responders to hazardous materials (HazMat) incidents is the heat strain that is caused by fully encapsulated impermeable (NFPA 1991) suits. In a research project, funded by the US Department of Defense, the thermal strain experienced when wearing these suits was studied. Forty human subjects between the ages of 25 and 50 participated in a protocol approved by the local ethical committee. Six different fully encapsulated impermeable HazMat suits were evaluated in three climates: moderate (24°C, 50% RH, 20°C WBGT), warm-wet (32°C, 60% RH, 30°C WBGT), and hot-dry (45°C, 20% RH, 37°C WBGT, 200 W m-2 radiant load) and at three walking speeds: 2.5, 4, and 5.5 km h-1. The medium speed, 4 km h-1, was tested in all three climates and the other two walking speeds were only tested in the moderate climate. Prior to the test a submaximal exercise test in normal clothing was performed to determine a relationship between heart rate and oxygen consumption (pretest). In total, 163 exposures were measured. Tolerance time ranged from as low as 20 min in the hot-dry condition to 60 min (the maximum) in the moderate climate, especially common at the lowest walking speed. Between the six difference suits limited differences were found, a two-layered aluminized suit exhibited significant shorter tolerance times in the moderate climate, but no other major significant differences were found for the other climates or workloads. An important characteristic of the overall dataset is the large variability between the subjects. Although the average responses seem suitable to be predicted, the variability in the warmer strain conditions ranged from 20 min up to 60 min. The work load in these encapsulated impermeable suits was also significantly higher than working in normal clothing and higher than predicted by the Pandolf equation. Heart rate showed a very strong correlation to body core temperature and was in many cases the limiting factor. Setting the heart rate

  16. Impact of Periodic Unsteadiness on Performance and Heat Load in Axial Flow Turbomachines

    Science.gov (United States)

    Sharma, Om P.; Stetson, Gary M.; Daniels, William A,; Greitzer, Edward M.; Blair, Michael F.; Dring, Robert P.

    1997-01-01

    Results of an analytical and experimental investigation, directed at the understanding of the impact of periodic unsteadiness on the time-averaged flows in axial flow turbomachines, are presented. Analysis of available experimental data, from a large-scale rotating rig (LSRR) (low speed rig), shows that in the time-averaged axisymmetric equations the magnitude of the terms representing the effect of periodic unsteadiness (deterministic stresses) are as large or larger than those due to random unsteadiness (turbulence). Numerical experiments, conducted to highlight physical mechanisms associated with the migration of combustor generated hot-streaks in turbine rotors, indicated that the effect can be simulated by accounting for deterministic stress like terms in the time-averaged mass and energy conservation equations. The experimental portion of this program shows that the aerodynamic loss for the second stator in a 1-1/2 stage turbine are influenced by the axial spacing between the second stator leading edge and the rotor trailing edge. However, the axial spacing has little impact on the heat transfer coefficient. These performance changes are believed to be associated with the change in deterministic stress at the inlet to the second stator. Data were also acquired to quantify the impact of indexing the first stator relative to the second stator. For the range of parameters examined, this effect was found to be of the same order as the effect of axial spacing.

  17. ITER-W monoblocks under high pulse number transient heat loads at high temperature

    Energy Technology Data Exchange (ETDEWEB)

    Loewenhoff, Th., E-mail: T.Loewenhoff@fz-juelich.de [Forschungszentrum Jülich, 52428 Jülich (Germany); Linke, J., E-mail: J.Linke@fz-juelich.de [Forschungszentrum Jülich, 52428 Jülich (Germany); Pintsuk, G., E-mail: G.Pintsuk@fz-juelich.de [Forschungszentrum Jülich, 52428 Jülich (Germany); Pitts, R.A., E-mail: Richard.Pitts@iter.org [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul-Lez-Durance (France); Riccardi, B., E-mail: Bruno.Riccardi@f4e.europa.eu [Fusion for Energy Joint Undertaking, Josep Pla No. 2 – T B3 7/01, Barcelona 08019 (Spain)

    2015-08-15

    In the context of using a full-tungsten (W) divertor for ITER, thermal shock resistance has become even more important as an issue that may potentially influence the long term performance. To address this issue a unique series of experiments has been performed on ITER-W monoblock mock ups in three EU high heat flux facilities: GLADIS (neutral beam), JUDITH 2 (electron beam) and Magnum-PSI (plasma beam). This paper discusses the JUDITH 2 experiments. Two different base temperatures, 1200 °C and 1500 °C, were chosen superimposed by ∼18,000/100,000 transient events (Δt = 0.48 ms) of 0.2 and 0.6 GW/m{sup 2}. Results showed a stronger surface deterioration at higher base temperature, quantified by an increase in roughening. This is intensified if the same test is done after preloading (exposure to high temperature without transients), especially at higher base temperature when the material recrystallizes.

  18. Thermoregulatory and Physiological Responses of Najdi Sheep Exposed to Environmental Heat Load Prevailing in Saudi Arabia

    Directory of Open Access Journals (Sweden)

    A. A. Al-Haidary, R. S. Aljumaah, M. A. Alshaikh, K. A. Abdoun*, E. M. Samara, A. B. Okab and M. M. Alfuraiji

    2012-10-01

    Full Text Available The objective of this study was to evaluate the thermoregulatory and physiological responses of Najdi rams raised under hot summer conditions prevailing in Kingdom Saudi Arabia. The core temperature (Tcore showed circadian rhythm characterized by biphasic achrophases, which were associated with the feeding times during both seasons. Average daily Tcore was significantly (P<0.05 higher under hot summer conditions. However, the amplitudes of the rhythmic oscillation during winter and summer seasons were 0.85 and 0.56C, respectively. Rectal (Tre and skin temperatures (Tsk were significantly (P<0.05 higher under hot summer conditions and exhibited similar patterns during both seasons concurrent with the pattern of temperature humidity index (THI, reaching the maximum values late in the afternoon and the minimum values early in the morning. Respiratory rate (RR and heart rate (HR showed the same pattern of the thermal parameters and were significantly (P<0.05 higher under hot summer conditions. Serum concentrations of total protein, globulin, glucose, sodium and chloride were significantly (P<0.05 increased while those of albumin and calcium were decreased under hot summer conditions. The results obtained from this study indicate that hot summer conditions of Saudi Arabia is thermally stressful to Najdi rams. Therefore, Najdi sheep production under such conditions would require environmental and/or nutritional modification to alleviate the impact of heat stress.

  19. Model of the heat load under dynamic abrasive processing of food material

    Directory of Open Access Journals (Sweden)

    G. V. Аlеksееv

    2016-01-01

    Full Text Available The modern stage of the improvement food production is conditioned by tense fight for their cost-performance that is defined in significant measure by maximum efficiency of the use agricultural cheese. At the same time problems with disadvantage ecological condition, accompanying life our society, require from taken person of the food different influences on recovery of the organism. For decision of this problem to researchers most different countries unite their own efforts on decision of the touched questions. The improvement and development technology must rest in study existing. In base of the studies can lie the mathematical product models of the feeding and corresponding to processes created in different exploratory organization. The development qualitative, claimed, competitive products – a purpose of each modern producer, choosing for itself most idle time, effective and economic justified way of the decision given problems. Modern prospecting in theories and practical person of the checking quality and analysis allow to use in principal new methods at determination of the possible negative changes to product of the feeding happened in them, in particular, under heat processing. The given methods, except traditional touch component, take into account else and complex of the analytical models of the models, for positioning undesirable warm-up mode for processing the product in target group of the consumers (for instance for integer medical-preventive feeding.

  20. Impact of heat stress on conception rate of dairy cows in the moderate climate considering different temperature-humidity index thresholds, periods relative to breeding, and heat load indices.

    Science.gov (United States)

    Schüller, L K; Burfeind, O; Heuwieser, W

    2014-05-01

    The objectives of this retrospective study were to investigate the relationship between temperature-humidity index (THI) and conception rate (CR) of lactating dairy cows, to estimate a threshold for this relationship, and to identify periods of exposure to heat stress relative to breeding in an area of moderate climate. In addition, we compared three different heat load indices related to CR: mean THI, maximum THI, and number of hours above the mean THI threshold. The THI threshold for the influence of heat stress on CR was 73. It was statistically chosen based on the observed relationship between the mean THI at the day of breeding and the resulting CR. Negative effects of heat stress, however, were already apparent at lower levels of THI, and 1 hour of mean THI of 73 or more decreased the CR significantly. The CR of lactating dairy cows was negatively affected by heat stress both before and after the day of breeding. The greatest negative impact of heat stress on CR was observed 21 to 1 day before breeding. When the mean THI was 73 or more in this period, CR decreased from 31% to 12%. Compared with the average maximum THI and the total number of hours above a threshold of more than or 9 hours, the mean THI was the most sensitive heat load index relating to CR. These results indicate that the CR of dairy cows raised in the moderate climates is highly affected by heat stress.

  1. Examination of material performance of W exposed to high heat load: Postmortem analysis of W exposed to TEXTOR plasma and E-beam test stand

    Science.gov (United States)

    Tanabe, T.; Philipps, V.; Nakamura, K.; Fujine, M.; Ueda, Y.; Wada, M.; Schweer, B.; Pospieszczyk, A.; Unterberg, B.

    1997-02-01

    We have examined the behavior of high Z limiters exposed to TEXTOR edge plasma and found that under certain conditions high Z materials are compatible with plasmas. In high density Ohmic plasmas the accumulation of a high Z impurity in the plasma center with significant radiation is observed, whereas an auxiliary heating like NBI and ICRH enhances the impurity exhaust with saw tooth activity. For a practical use of high Z plasma facing materials, extremely high heat load from the plasma becomes a serious concern. In the present work we have conducted the high heat load tests of tungsten (W) using two different heat sources, one is the W limiter exposed to TEXTOR plasma and the other is various W samples heat loaded with an intense E-beam using the JEBIS facility in Japan Atomic Energy Research Institute (JAERI). From the test results we have to conclude that W, if applied in the form of the bulk material, should be used above the ductile brittle transition temperature (DBTT) but below about 1500°C to avoid the recrystallization. Maximum heat load tolerable without surface melting is about 20 MW/m 2 for several seconds. The monocrystalline used at high temperatures shows very good performance, though the production of the monocrystalline with a desired shape is not easy. Considering its brittle nature, hard machining and heavy mass, bulk W cannot be a structure material but be used as a thin tile or deposited film on some structure materials. Unfortunately, however, the thermal expansion coefficient of W is so small that brazing of W to a heat sink material like Cu which has a much larger thermal expansion coefficient would easily result in cracking due to the large thermal stress. Thus the development of tungsten plasma facing component (PFC) needs much effort in future.

  2. Effect of volume loading on the Frank-Starling relation during reductions in central blood volume in heat-stressed humans

    DEFF Research Database (Denmark)

    Bundgaard-Nielsen, Morten; Wilson, T E; Seifert, Thomas

    2010-01-01

    During reductions in central blood volume while heat stressed, a greater decrease in stroke volume (SV) for a similar decrease in ventricular filling pressure, compared to normothermia, suggests that the heart is operating on a steeper portion of a Frank-Starling curve. If so, volume loading of h...

  3. Effect of dry heat and steam sterilization on load-deflection characteristics of β-titanium wires: An in vitro study

    Directory of Open Access Journals (Sweden)

    Shiva Alavi

    2012-01-01

    Conclusion: It appears dry heat sterilization increases stiffness of RES, BETA, CNA and HONE but autoclave sterilization did not have any effect on load-deflection characteristics of most of the β-titanium wires tested, indicating that clinicians who want to provide maximum safety for their patients can autoclave TMAL, RES and CNA before applying them.

  4. Building America Case Study: Calculating Design Heating Loads for Superinsulated Buildings, Ithaca, New York; Technology Solutions for New and Existing Homes, Energy Efficiency & Renewable Energy (EERE)

    Energy Technology Data Exchange (ETDEWEB)

    None

    2015-08-01

    Designing a superinsulated home has many benefits including improved comfort, reduced exterior noise penetration, lower energy bills, and the ability to withstand power and fuel outages under much more comfortable conditions than a typical home. Extremely low heating and cooling loads equate to much smaller HVAC equipment than conventionally required. Sizing the mechanical system to these much lower loads reduces first costs and the size of the distribution system needed. While these homes aren't necessarily constructed with excessive mass in the form of concrete floors and walls, the amount of insulation and the increase in the thickness of the building envelope can lead to a mass effect, resulting in the structures ability to store much more heat than a code built home. This results in a very low thermal inertia making the building much less sensitive to drastic temperature swings thereby decreasing the peak heating load demand. Alternative methods that take this inertia into account along with solar and internal gains result in smaller more appropriate design loads than those calculated using Manual J version 8. During the winter of 2013/2014, CARB monitored the energy use of three homes in climate zone 6 in an attempt to evaluate the accuracy of two different mechanical system sizing methods for low load homes. Based on the results, it is recommended that internal and solar gains be included and some credit for thermal inertia be used in sizing calculations for superinsulated homes.

  5. Optimised Cockpit Heat Load Analysis using Skin Temperature Predicted by CFD and Validation by Thermal Mapping to Improve the Performance of Fighter Aircraft

    Directory of Open Access Journals (Sweden)

    Paresh Gupta

    2015-03-01

    Full Text Available Designing of optimum environmental control system (ECS plays a major role for increasing performance of fighter aircraft depending upon requirement of engine bleed air for running of ECS. Accurate estimation of cockpit skin temperature for obtaining optimised cockpit heat load helps in estimation of engine bleed air for ECS. Present research evolved a methodology for comparing the theoretically calculated skin temperature with computational fluid dynamics (CFD analysis to obtain optimum skin temperature. Results are validated by flight tests under critical flight conditions using thermal crayons. Based on which the optimized heat load and bleed air requirements has been computed. Uncertainty analysis of skin temperature measurement for thermal crayons have been undertaken. The results indicate that the theoretical skin temperature is -26.70 per cent as that of CFD estimated skin temperature. Optimized average cockpit heat load at critical flight profiles is 0.74 times the theoretical cockpit heat load, leading to reduction of bleed air requirement by 26 per cent as compared to theoretical. Due to this literature survey has pridicted the increase in performance parameters like increase in bleed air pressure by 78 per cent, increase in thrust by 60 per cent, and decrease in specific fuel consumption (SFC by 40 per cent to improve the endurance of aircraft. The research has generated governing equations for variation of cockpit heat loads w.r.t aircraft skin temperatures.Defence Science Journal, Vol. 65, No. 1, January 2015, pp.12-24, DOI:http://dx.doi.org/10.14429/dsj.65.7200

  6. Near-infrared dye loaded polymeric nanoparticles for cancer imaging and therapy and cellular response after laser-induced heating

    Directory of Open Access Journals (Sweden)

    Tingjun Lei

    2014-03-01

    Full Text Available Background: In the past decade, researchers have focused on developing new biomaterials for cancer therapy that combine imaging and therapeutic agents. In our study, we use a new biocompatible and biodegradable polymer, termed poly(glycerol malate co-dodecanedioate (PGMD, for the synthesis of nanoparticles (NPs and loading of near-infrared (NIR dyes. IR820 was chosen for the purpose of imaging and hyperthermia (HT. HT is currently used in clinical trials for cancer therapy in combination with radiotherapy and chemotherapy. One of the potential problems of HT is that it can up-regulate hypoxia-inducible factor-1 (HIF-1 expression and enhance vascular endothelial growth factor (VEGF secretion.Results: We explored cellular response after rapid, short-term and low thermal dose laser-IR820-PGMD NPs (laser/NPs induced-heating, and compared it to slow, long-term and high thermal dose heating by a cell incubator. The expression levels of the reactive oxygen species (ROS, HIF-1 and VEGF following the two different modes of heating. The cytotoxicity of NPs after laser/NP HT resulted in higher cell killing compared to incubator HT. The ROS level was highly elevated under incubator HT, but remained at the baseline level under the laser/NP HT. Our results show that elevated ROS expression inside the cells could result in the promotion of HIF-1 expression after incubator induced-HT. The VEGF secretion was also significantly enhanced compared to laser/NP HT, possibly due to the promotion of HIF-1. In vitro cell imaging and in vivo healthy mice imaging showed that IR820-PGMD NPs can be used for optical imaging.Conclusion: IR820-PGMD NPs were developed and used for both imaging and therapy purposes. Rapid and short-term laser/NP HT, with a low thermal dose, does not up-regulate HIF-1 and VEGF expression, whereas slow and long term incubator HT, with a high thermal dose, enhances the expression of both transcription factors.

  7. Effect of high-flux H/He plasma exposure on tungsten damage due to transient heat loads

    Energy Technology Data Exchange (ETDEWEB)

    De Temmerman, G., E-mail: gregory.detemmerman@iter.org [FOM Institute DIFFER, Dutch Institute for Fundamental Energy Research, Association EURATOM-FOM, Trilateral Euregion Cluster, Postbus 1207, 3430BE Nieuwegein (Netherlands); ITER Organization, Route de Vinon sur Verdon, CS 90 096, 13067 Saint Paul-lez-Durance (France); Morgan, T.W.; Eden, G.G. van; Kruif, T. de [FOM Institute DIFFER, Dutch Institute for Fundamental Energy Research, Association EURATOM-FOM, Trilateral Euregion Cluster, Postbus 1207, 3430BE Nieuwegein (Netherlands); Wirtz, M. [Forschungszentrum Jülich GmbH, Institute of Energy and Climate Research – Microstructure and Properties of Materials (IEK-2), EURATOM Association, 52425 Jülich (Germany); Matejicek, J.; Chraska, T. [Institute of Plasma Physics, Association EURATOM-IPP, CR Prague (Czech Republic); Pitts, R.A. [ITER Organization, Route de Vinon sur Verdon, CS 90 096, 13067 Saint Paul-lez-Durance (France); Wright, G.M. [MIT Plasma Science and Fusion Center, 77 Massachusetts Ave., Cambridge, MA 02139 (United States)

    2015-08-15

    The thermal shock behaviour of tungsten exposed to high-flux plasma is studied using a high-power laser. The cases of laser-only, sequential laser and hydrogen (H) plasma and simultaneous laser plus H plasma exposure are studied. H plasma exposure leads to an embrittlement of the material and the appearance of a crack network originating from the centre of the laser spot. Under simultaneous loading, significant surface melting is observed. In general, H plasma exposure lowers the heat flux parameter (F{sub HF}) for the onset of surface melting by ∼25%. In the case of He-modified (fuzzy) surfaces, strong surface deformations are observed already after 1000 laser pulses at moderate F{sub HF} = 19 MJ m{sup −2} s{sup −1/2}, and a dense network of fine cracks is observed. These results indicate that high-fluence ITER-like plasma exposure influences the thermal shock properties of tungsten, lowering the permissible transient energy density beyond which macroscopic surface modifications begin to occur.

  8. In-Situ Neutron Diffraction Under Tensile Loading of Powder-in-Tube Cu/Nb3Sn Composite Wires Effect of Reaction Heat Treatment on Texture, Internal Stress State and Load Transfer

    CERN Document Server

    Scheuerlein, C; Thilly, L

    2007-01-01

    The strain induced degradation of Nb3Sn superconductors can hamper the performance of high field magnets. We report elastic strain measurements in the different phases of entire non-heat treated and fully reacted Nb3Sn composite strands as a function of uniaxial stress during in-situ deformation under neutron beam. After the reaction heat treatment the Cu matrix loses entirely its load carrying capability and the applied stress is transferred to the remaining Nb-Ta alloy and to the brittle (Nb-Ta)3Sn phase, which exhibits a preferential grain orientation parallel to the strand axis.

  9. Synchrotrons for Hadrontherapy

    Science.gov (United States)

    Pullia, Marco G.

    Since 1990, when the world's first hospital-based proton therapy center opened in Loma Linda, California, interest in dedicated proton and carbon ion therapy facilities has been growing steadily. Today, many proton therapy centers are in operation, but the number of centers offering carbon ion therapy is still very low. This difference reflects the fact that protons are well accepted by the medical community, whereas radiotherapy with carbon ions is still experimental. Furthermore, accelerators for carbon ions are larger, more complicated and more expensive than those for protons only. This article describes the accelerator performance required for hadrontherapy and how this is realized, with particular emphasis on carbon ion synchrotrons.

  10. Will we be heating with green electricity tomorrow? The large potential of load-variable private customer tariffs; Heizen wir kuenftig mit Oekostrom? Das grosse Potenzial lastvariabler Privatkundentarife

    Energy Technology Data Exchange (ETDEWEB)

    Zierdt, Tobias; Lang, Dirk [RWE Effizienz GmbH, Dortmund (Germany)

    2012-09-15

    Momentous changes loom ahead for Germany's energy supply system as a result of the energy turnaround. One central question is how load peaks from renewable energy plants can be conveniently accommodated on the demand side. Two research projects are currently being carried out to examine the acceptance of time-variable and load-variable tariffs for private households. First results show that using green electricity for heat generation is significantly more attractive for both customers and energy suppliers than using it to cover day-to-day electricity demand at a later time.

  11. Effect of volume loading on the Frank-Starling relation during reductions in central blood volume in heat-stressed humans.

    Science.gov (United States)

    Bundgaard-Nielsen, M; Wilson, T E; Seifert, T; Secher, N H; Crandall, C G

    2010-09-01

    During reductions in central blood volume while heat stressed, a greater decrease in stroke volume (SV) for a similar decrease in ventricular filling pressure, compared to normothermia, suggests that the heart is operating on a steeper portion of a Frank-Starling curve. If so, volume loading of heat-stressed individuals would shift the operating point to a flatter portion of the heat stress Frank-Starling curve thereby attenuating the reduction in SV during subsequent decreases in central blood volume. To investigate this hypothesis, right heart catheterization was performed in eight males from whom pulmonary capillary wedge pressure (PCWP), central venous pressure and SV (via thermodilution) were obtained while central blood volume was reduced via lower-body negative pressure (LBNP) during normothermia, whole-body heating (increase in blood temperature 1 degrees C), and during whole-body heating after intravascular volume expansion. Volume expansion was accomplished by administration of a combination of a synthetic colloid (HES 130/0.4, Voluven) and saline. Before LBNP, SV was not affected by heating (122 +/- 30 ml; mean +/- s.d.) compared to normothermia (110 +/- 20 ml; P = 0.06). However, subsequent volume loading increased SV to 143 +/- 29 ml (P = 0.003). LBNP provoked a larger decrease in SV relative to the decrease in PCWP during heating (8.6 +/- 1.9 ml mmHg(1)) compared to normothermia (4.5 +/- 3.0 ml mmHg(1), P = 0.02). After volume loading while heat stressed, the reduction in the SV to PCWP ratio during LBNP was comparable to that observed during normothermia (4.8 +/- 2.3 ml mmHg(1); P = 0.78). These data support the hypothesis that a Frank-Starling mechanism contributes to compromised blood pressure control during simulated haemorrhage in heat-stressed individuals, and extend those findings by showing that volume infusion corrects this deficit by shifting the operating point to a flatter portion of the heat stress Frank-Starling curve.

  12. 13000 a current lead with 1.5 W heat load to 4.5 K for the Large Hadron Collider at CERN

    CERN Document Server

    Good, J A; Martini, L

    2000-01-01

    Cryogenic Ltd. and ENEL S.p.A. have collaborated on the design and construction of prototype current leads for the Large Hadron Collider project at CERN, Geneva. The aim is to deliver a direct current of 13 kA into a 4.5 K liquid helium bath with a total heat load of less than 1.5 W. These hybrid leads transport the current via a resistive heat exchanger cooled by a separate source of helium gas in the high temperature region, and below 50 K via self-cooled high temperature superconductor. (6 refs).

  13. The effect of food location, heat load, and intrusive medical procedures on brushing activity in dairy cows.

    Science.gov (United States)

    Mandel, R; Whay, H R; Nicol, C J; Klement, E

    2013-10-01

    Animals allocate time and effort to a range of core (e.g., sleeping, feeding, drinking) and "luxury" (e.g., playing, exploring) activities. A luxury activity is characterized by low resilience and, as such, will be reduced when time or energy resources are limited, including under conditions of stress or discomfort. One seemingly luxurious activity available to cows on an increasing number of dairy farms is rubbing against an automated brush. The current study examined the effect of distance from food, heat load, and an intrusive medical procedure (i.e., artificial insemination and transrectal pregnancy examination) on the resilience of brush usage. The probability of using the brush decreased significantly when food was located distantly from the brush (mean=0.53) compared with days when food was located closer to the brush (mean=0.81). Brush usage also decreased at high temperature and humidity levels, with an average decrease of 0.062 brushing events for an increase of 1 temperature-humidity index unit (95% confidence interval=-0.93-0.030). In addition, a significant reduction of approximately 50% in brushing activity was observed on days of artificial insemination compared with the preceding 3d and the following 3d. These findings show that brush usage is a low resilience activity that reduces under a range of conditions. It may thus have the potential to be used as an indicator of a range of health and welfare problems in cows. Further research should be conducted to assess the sensitivity and specificity of this suggested tool and its possible contribution to the early detection of morbidity.

  14. Reminder of the edge effect in Synchrotron radiation

    CERN Document Server

    Burkhardt, H

    1998-01-01

    The synchrotron radiation in the LHC will be rather soft and weak, compared to high energy electron machines. Still it is expected to generate non negligible heating and photon-induced gas desorption. A summary of standard formulas and numbers for the LHC have been collected in this note, including a very rough discussion of the spectrum shift expected by the edge effect.

  15. Simple models of district heating systems for load and demand side management and operational optimisation; Simple modeller for fjernvarmesystemer med henblik pae belastningsudjaevning og driftsoptimering

    Energy Technology Data Exchange (ETDEWEB)

    Boehm, B. [Technical Univ. of Denmark, Dept. of Mechanical Engineering, Kgs. Lyngby (Denmark); Larsen, H.V. [Risoe National Lab., System Analysis Dept., Roskilde (DK)

    2004-12-01

    The purpose of this research project has been to further develop and test simple (aggregated) models of district heating (DH) systems for simulation and operational optimization, and to investigate the influence of Load Management and Demand Side Management (DMS) on the total operational costs. The work is based on physical-mathematical modelling and simulation of DH systems, and is a continuation of previous EFP-96 work. In the present EFP-2001 project the goals have been to improve the Danish method of aggregation by addressing the problem of aggregation of pressure losses, and to test the methods on a much larger data set than in the EFP-1996 project. In order to verify the models it is crucial to have good data at disposal. Full information on the heat loads and temperatures not only at the DH plant but also at every consumer (building) is needed, and therefore only a few DH systems in Denmark can supply such data. (BA)

  16. Damage and fatigue crack growth of Eurofer steel first wall mock-up under cyclic heat flux loads. Part 2: Finite element analysis of damage evolution

    Energy Technology Data Exchange (ETDEWEB)

    You, Jeong-Ha, E-mail: you@ipp.mpg.de

    2014-04-15

    Highlights: • The surface heat flux load of 3.5 MW/m{sup 2} produced substantial stresses and inelastic strains in the heat-loaded surface region, especially at the notch root. • The notch root exhibited a typical notch effect such as stress concentration and localized inelastic yield leading to a preferred damage development. • The predicted damage evolution feature agrees well with the experimental observation. • The smooth surface also experiences considerable stresses and inelastic strains. However, the stress intensity and the amount of inelastic deformation are not high enough to cause any serious damage. • The level of maximum inelastic strain is higher at the notch root than at the smooth surface. On the other hand, the amplitude of inelastic strain variation is comparable at both positions. • The amount of inelastic deformation is significantly affected by the length of pulse duration time indicating the important role of creep. - Abstract: In the preceding companion article (part 1), the experimental results of the high-heat-flux (3.5 MW/m{sup 2}) fatigue tests of a Eurofer bare steel first wall mock-up was presented. The aim was to investigate the damage evolution and crack initiation feature. The mock-up used there was a simplified model having only basic and generic structural feature of an actively cooled steel FW component for DEMO reactor. In that study, it was found that microscopic damage was formed at the notch root already in the early stage of the fatigue loading. On the contrary, the heat-loaded smooth surface exhibited no damage up to 800 load cycles. In this paper, the high-heat-flux fatigue behavior is investigated with a finite element analysis to provide a theoretical interpretation. The thermal fatigue test was simulated using the coupled damage-viscoplastic constitutive model developed by Aktaa. The stresses, inelastic deformation and damage evolution at the notch groove and at the smooth surface are compared. The different

  17. Effect on the load size on the efficiency of microwave heating under stop flow and continuous flow conditions

    NARCIS (Netherlands)

    Patil, N.G.; Rebrov, E.V.; Esveld, D.C.; Eränen, K.; Benaskar, F.; Meuldijk, Jan; Mikkola, J.P.; Hessel, V.; Hulshof, L.A.; Murzin, D.Y.; Schouten, J.C.

    2012-01-01

    A novel heating efficiency analysis of the microwave heated stop-flow (i.e. stagnant
    liquid) and continuous-flow reactors has been presented. The thermal losses to the surrounding
    air by natural convection have been taken into account for heating efficiency calculation of
    the microwave

  18. Effect on the load size on the efficiency of microwave heating under stop flow and continuous flow conditions

    NARCIS (Netherlands)

    Patil, N.G.; Rebrov, E.V.; Esveld, D.C.; Eränen, K.; Benaskar, F.; Meuldijk, Jan; Mikkola, J.P.; Hessel, V.; Hulshof, L.A.; Murzin, D.Y.; Schouten, J.C.

    2012-01-01

    A novel heating efficiency analysis of the microwave heated stop-flow (i.e. stagnant
    liquid) and continuous-flow reactors has been presented. The thermal losses to the surrounding
    air by natural convection have been taken into account for heating efficiency calculation of
    the microwave h

  19. Bystander Effects During Synchrotron Imaging Procedures?

    Science.gov (United States)

    Schültke, Elisabeth; Bewer, Brian; Wysokinski, Tomasz; Chapman, Dean; Nikkhah, Guido

    2010-07-01

    Using monochromatic beam and synchrotron phase-contrast technique at the biomedical beamline of the Italian synchrotron facility Elettra (SYRMEP), we have shown in a small animal model of malignant brain tumor that it is possible to obtain high-resolution images of very small tumors when they have developed from implanted tumor cells loaded with colloidal gold nanoparticles (GNP). All previous experiments were conducted in post-mortem samples. We have now designed a cell culture experiment to investigate the effects of synchrotron radiation with an energy and dose profile similar to that expected in our first in vivo imaging studies according to the protocol developed at SYRMEP. Materials and Methods: Culture flasks containing either gold-loaded or naïve C6 glioma cells were exposed to a dose of 0.5 Gy at 24 keV. The irradiated medium was aspirated and replaced with fresh growth medium. Twenty-four hours later this non-irradiated medium exposed to irradiated cells was aspirated, then added to non-irradiated C6 cells in order to investigate whether bystander effects are seen under the conditions of our image acquisition protocol. The irradiated medium was added to a number of other non-irradiated cell cultures. Cell counts were followed until 72 hrs after irradiation. Western blots were conducted with H2AX antibodies. This experiment was one of the first biomedical experiments conducted at BMIT, the new biomedical imaging and therapy beamline of the Canadian Light Source. Results: No significant differences in proliferation were seen between cells that were directly irradiated, exposed to irradiated medium or exposed to the non-irradiated 24-hr-medium from the irradiated cells. However, there was a tendency towards a higher number of double strand breaks in previously irradiated cells when they were exposed to non-irradiated medium that had been in contact with irradiated cells for 24 hrs.

  20. Preliminary analysis of effects of thermal loading on gas and heat flow within the framework of the LBNL/USGS site-scale model

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Y.S.; Chen, G.; Bodvarsson, G.

    1995-12-01

    The US Department of Energy is performing detailed site characterization studies at Yucca Mountain to determine its suitability as a geological repository site for high level nuclear wastes. As part of these research efforts, a three-dimensional, site-scale unsaturated-zone model has been developed at Lawrence Berkeley National Laboratory (LBNL) in collaboration with the US Geological Survey (USGS). The primary objectives of developing the 3-D site-scale model are to predict the ambient hydrogeological conditions and the movement of moisture and gas within the unsaturated zone of the mountain. In addition, the model has the capability of modeling non-isothermal flow and transport phenomena at the mountain. Applications of such a site-scale model should include evaluation of effects of thermal loading on heated gas and heat flow through the mountain for long-term performance assessment of the repository. Emplacement of heat-generating, high-level nuclear wastes at Yucca Mountain would create complex multiphase fluid flow and heat transfer processes. The physical mechanisms include conductive and convective heat transfer, phase change phenomena (vaporization and condensation), flow of liquid and gas phases under variably-saturated condition, diffusion and dispersion of vapor and gas, vapor sorption, and vapor-pressure lowering effects. The heterogeneity of complicated geological setting at Yucca Mountain, such as alternating, layers of porous-fractured rocks, will significantly affect the processes of fluid and heat flow.

  1. Technology Solutions Case Study: Air-To-Water Heat Pumps with Radiant Delivery in Low Load Homes, Tucson, Arizona and Chico, California

    Energy Technology Data Exchange (ETDEWEB)

    None

    2013-11-01

    Space conditioning represents nearly 50% of average residential household energy consumption, highlighting the need to identify alternative cost-effective, energy-efficient cooling and heating strategies. As homes are better built, there is an increasing need for strategies that are particularly well suited for high performance, low load homes. ARBI researchers worked with two test homes in hot-dry climates to evaluate the in-situ performance of air-to-water heat pump (AWHP) systems, an energy efficient space conditioning solution designed to cost-effectively provide comfort in homes with efficient, safe, and durable operation. Both systems were fully instrumented and have been monitored over one year to capture complete performance data over the cooling and heating seasons. Results are used to quantify energy savings, cost-effectiveness, and system performance using different operating modes and strategies. This strategy is most effective in tight, insulated homes with high levels of thermal mass (i.e. exposed slab floors).

  2. Generation of Domestic Hot Water, Space Heating and Driving Pattern Profiles for Integration Analysis of Active Loads in Low Voltage Grids

    DEFF Research Database (Denmark)

    Diaz de Cerio Mendaza, Iker; Pigazo, Alberto; Bak-Jensen, Birgitte

    2013-01-01

    demand and electric vehicle driving profiles, to be used for power grid calculations. The generated thermal profiles relied on a statistical analysis made from real domestic hot water and space heating data from 25 households of a typical Danish residential area. The driving profiles instead were formed......The changes in the Danish energy sector, consequence of political agreements, are expected to have direct impact in the actual power distribution systems. Large number of electric boiler, heat pumps and electric vehicles are planned and will cope large percentage of the future power consumption...... at household level. Despite of the well-known flexible service that this kind of loads can provide, their flexibility is highly dependent of the domestic hot water and space heating demand and the driving habits of each user. This paper presents two methodologies employed to randomly generate thermal power...

  3. Study on operating mode of solar-earth source heat pump system with dynamic heating load%基于动态热负荷的太阳能——地源热泵运行模式研究

    Institute of Scientific and Technical Information of China (English)

    李素芬; 韩伟; 代兰花

    2011-01-01

    建立了太阳能-地源热泵系统一体化模型,以大连地区气候条件为基础,计算了供暖季某天内房间热负荷的逐时值.在动态热负荷基础上,对联合供暖系统在不同串联运行模式和并联运行模式不同分流比的运行工况进行了模拟计算,将模拟结果与实脸数据对比,两者吻合较好.结果表明:房间热负荷的变化可影响热泵机组COP.联合运行模式在地温的恢复和系统节能方面均占优势.%An integrative model of the solar-earth source heat pump system (SESHPS) is proposed in this study. Based on the local climate condition (Dalian) , the heat load of heating season by one day iscalculated. The simulation of different series-connected modes is conducted. Furthermore, the simulations are also repeated for different shunt ratio of the same parallel connection mode on the condition of dynamic heating load. The numerical result was compared with the experimental data and they agree with each other very well. The result indicates that COP is disturbed by the change of the heating load and the recovery of ground temperature and the energy efficiency is excellent in the joint operation mode.

  4. Low-cost multi-vehicle air temperature measurements for heat load assessment in local-scale climate applications

    Science.gov (United States)

    Zuvela-Aloise, Maja; Weyss, Gernot; Aloise, Giulliano; Mifka, Boris; Löffelmann, Philemon; Hollosi, Brigitta; Nemec, Johana; Vucetic, Visnja

    2014-05-01

    In the recent years there has been a strong interest in exploring the potential of low-cost measurement devices as alternative source of meteorological monitoring data, especially in the urban areas where high-density observations become crucial for appropriate heat load assessment. One of the simple, but efficient approaches for gathering large amount of spatial data is through mobile measurement campaigns in which the sensors are attached to driving vehicles. However, non-standardized data collecting procedure, instrument quality, their response-time and design, variable device ventilation and radiation protection influence the reliability of the gathered data. We investigate what accuracy can be expected from the data collected through low-cost mobile measurements and whether the achieved quality of the data is sufficient for validation of the state-of-the-art local-scale climate models. We tested 5 types of temperature sensors and data loggers: Maxim iButton, Lascar EL-USB-2-LCD+ and Onset HOBO UX100-003 as market available devices and self-designed solar powered Arduino-based data loggers combined with the AOSONG AM2315 and Sensirion SHT21 temperature and humidity sensors. The devices were calibrated and tested in stationary mode at the Austrian Weather Service showing accuracy between 0.1°C and 0.8°C, which was mostly within the device specification range. In mobile mode, the best response-time was found for self-designed device with Arduino-based data logger and Sensirion SHT21 sensor. However, the device lacks the mechanical robustness and should be further improved for broad-range applications. We organized 4 measurement tours: two taking place in urban environment (Vienna, Austria in July 2011 and July 2013) and two in countryside with complex terrain of Mid-Adriatic islands (Hvar and Korcula, Croatia in August 2013). Measurements were taken on clear-sky, dry and hot days. We combined multiple devices attached to bicycle and cars with different

  5. Synchrotron radiation measurement of multiphase fluid saturations in porous media: Experimental technique and error analysis

    Science.gov (United States)

    Tuck, David M.; Bierck, Barnes R.; Jaffé, Peter R.

    1998-06-01

    Multiphase flow in porous media is an important research topic. In situ, nondestructive experimental methods for studying multiphase flow are important for improving our understanding and the theory. Rapid changes in fluid saturation, characteristic of immiscible displacement, are difficult to measure accurately using gamma rays due to practical restrictions on source strength. Our objective is to describe a synchrotron radiation technique for rapid, nondestructive saturation measurements of multiple fluids in porous media, and to present a precision and accuracy analysis of the technique. Synchrotron radiation provides a high intensity, inherently collimated photon beam of tunable energy which can yield accurate measurements of fluid saturation in just one second. Measurements were obtained with precision of ±0.01 or better for tetrachloroethylene (PCE) in a 2.5 cm thick glass-bead porous medium using a counting time of 1 s. The normal distribution was shown to provide acceptable confidence limits for PCE saturation changes. Sources of error include heat load on the monochromator, periodic movement of the source beam, and errors in stepping-motor positioning system. Hypodermic needles pushed into the medium to inject PCE changed porosity in a region approximately ±1 mm of the injection point. Improved mass balance between the known and measured PCE injection volumes was obtained when appropriate corrections were applied to calibration values near the injection point.

  6. Reshuffle lifts French synchrotron hopes

    CERN Multimedia

    McCabe, H

    2000-01-01

    The sacking of Claude Allegre as research minister has raised doubts over the level of France's promised participation in the construction of Diamond but reawakened French hopes that the synchrotron Soleil may now be built (1 page).

  7. Regions compete for French synchrotron

    CERN Multimedia

    2000-01-01

    Ten regions in France have placed bids to host the planned national synchrotron Soleil. Leading contenders include a joint bid from Ile-de-France and Essonne for Orsay, offering FF 1 billion towards the construction costs (2 paragraphs).

  8. Proton synchrotron radiation at Fermilab

    Energy Technology Data Exchange (ETDEWEB)

    Thurman-Keup, Randy; /Fermilab

    2006-05-01

    While protons are not generally associated with synchrotron radiation, they do emit visible light at high enough energies. This paper presents an overview of the use of synchrotron radiation in the Tevatron to measure transverse emittances and to monitor the amount of beam in the abort gap. The latter is necessary to ensure a clean abort and prevent quenches of the superconducting magnets and damage to the silicon detectors of the collider experiments.

  9. Transfiguration of extracting mirror in synchrotron radiation system at SSRF

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    The first extracting mirror is very important for synchrotron radiation monitor (SRM). The SRM system of SSRF (Shanghai Synchrotron Radiation Facility) should extract the visible light with low optical distortion. The analysis of SR power spectrum and heat transfiguration based on Matlab is introduced in this paper, which will be used in calibration. One beryllium mirror with water-cooling is used to transmit X-ray and reflect visible light to satisfy the measurement request. The existing system suffers from a dynamic problem in some beam physics study. The system includes optics, image acquisition and interferometers. One of the instruments is a digital camera providing the image of the beam transverse profile. The hardware configuration will be summarized. The synchrotron radiation measurement system has been in operation in SSRF for more than one year.

  10. Change in heat load profile for typical Danish multi-storey buildings when energy-renovated and supplied with low-temperature district heating

    DEFF Research Database (Denmark)

    Harrestrup, Maria; Svendsen, Svend

    2013-01-01

    for the future DH-systems and in order to avoid oversized RE-based capacity, a long-term perspective needs to be taken. The results show that it is possible to design the DH-plants based on an average value of the 5 days with highest daily average loads without compromising with indoor thermal comfort. Applying...

  11. Part-Load Performance Prediction and Operation Strategy Design of Organic Rankine Cycles with a Medium Cycle Used for Recovering Waste Heat from Gaseous Fuel Engines

    Directory of Open Access Journals (Sweden)

    Xuan Wang

    2016-07-01

    Full Text Available The Organic Rankine Cycle (ORC is regarded as a suitable way to recover waste heat from gaseous fuel internal combustion engines. As waste heat recovery systems (WHRS have always been designed based on rated working conditions, while engines often work under part-load conditions, it is quite significant to analyze the part-load performance and corresponding operation strategy of ORC systems. This paper presents a dynamic model of ORC with a medium cycle used for a large gaseous fuel engine and analyzes the effect of adjustable parameters on the system performance, giving effective control directions under various conditions. The results indicate that the intermediary fluid mass flow rate has nearly no effect on the output power and thermal efficiency of the ORC, while the mass flow rate of working fluid has a great effect on them. In order to get a better system performance under different working conditions, the system should be operated with the working fluid mass flow rate as large as possible, but with a slight degree of superheating. Then, with the control of constant superheat degree at the end of the heating process, the performance of the combined system that consists of ORC and the engine at steady state under seven typical working conditions is also analyzed. The results indicate that the energy-saving effect of WHRS becomes worse and worse as the working condition decreases. Especially at 40% working condition the WHRS nearly has no energy-saving effect anymore.

  12. How low can the low heating load density district heating be? Environmental aspects on low heating load density district heating of the present generation compared to a domestic oil burner; Hur vaermegles kan den vaermeglesa fjaerrvaermen vara? Miljoeaspekter paa vaermegles fjaerrvaerme med dagens teknik jaemfoerd med villaoljepanna

    Energy Technology Data Exchange (ETDEWEB)

    Froeling, Morgan [Chalmers Univ. of Technology, Goeteborg (Sweden). Dept. of Chemical Environmental Science

    2005-07-01

    In Sweden we can see an increase of district heating networks in residential areas with low heat density. For the customer the economy is normally the most important argument when deciding to choose district heating. For many customers, however, arguments regarding environmental friendliness are important complimentary arguments. When district heating systems are built with decreased heat density, the environmental impacts from use of district heating will increase, depending on such as increased need of pipes and increased heat losses from the distribution system. The purpose of this study is to investigate if there is a limit, a lowest heat density when it is not any longer beneficial to build district heating when district heating replaces local oil furnace heating. Life cycle inventory data for district heating distribution systems in areas with low heat density has been compared with the use of oil furnaces. The environmental impacts are categorized into Global Warming Potential, Acidification Potential, Eutrofication Potential and Use of Finite Resources. To enhance the assessment three single point indicators have also been used: EcoIndicator99, EPS and ExternE. The economics of using district heating in areas with low heat density has not been regarded in this study. A model comparing the space heating of a single family home with an oil furnace or with district heating has been created. The home has an annual heat need of 20 MWh. The district heating distribution network is characterized by its linear heat density. The linear heat density is a rough description of a district heating network, and thus also the results from the model will be general. Still it can give us a general idea of the environmental limit for district heating in areas with low heat density. An assessment of all results indicate that with the type of technology used at present it is not environmentally beneficial to use district heating with lower linear heat density than 0,2 MWh/m. At

  13. Deuterium retention in tungsten under combined high cycle ELM-like heat loads and steady-state plasma exposure

    Directory of Open Access Journals (Sweden)

    A. Huber

    2016-12-01

    Enhanced blister formation has been observed under combined loading conditions at power densities close to the threshold for damaging. It is shown that blisters are not mainly responsible for the pronounced increase of the D retention.

  14. Effect of Cobalt Fillers on Polyurethane Segmentations Investigated by Synchrotron Small Angle X-Ray Scattering

    Directory of Open Access Journals (Sweden)

    Krit Koyvanich

    2013-01-01

    Full Text Available The segmentation between rigid and rubbery chains in polyurethanes (PUs influences polymeric properties and implementations. Several models have successfully been proposed to visualize the configuration between the hard segment (HS and soft segment (SS. For particulate PU composites, the arrangement of HS and SS is more complicated because the fillers tend to disrupt the chain formation and segmentation. In this work, the effect of ferromagnetic cobalt (Co powders (average diameter 2 μm on PU synthesized from a reaction between polyether polyol (soft segment and diphenylmethane-4,4′-diisocyanate (hard segment was studied with varying loadings (0, 20, 40, and 60 wt.%. The 300 μm thick PU/Co samples were tape-casted and then received heat treatment at 80°C for 180 min. From synchrotron small angle X-ray scattering (SAXS, the plot of the X-ray scattering intensity (I against the scattering vector (q exhibited a typical single peak of PU whose intensity was reduced by the increase in the Co loading. Characteristic SAXS peaks in the case of 0-20 wt.% Co agreed well with the scattering by globular hard segment domains according to Zernike-Prins and Percus-Yevick models. The higher Co loadings led to larger deviations from all theoretical models.

  15. Beam induced heat loads on the beam-screens of the twin-bore magnets in the IRs of the HL-LHC

    CERN Document Server

    Iadarola, Giovanni; Rumolo, Giovanni

    2016-01-01

    The expected heat load induced on the beam screens has been evaluated for all the twin-bore magnets in the Insertion Regions (IRs) of the HL-LHC. The contribution from the impedance of the beam screen has been evaluated taking into account the presence of a longitudinal weld in the beam screen and the impact of the temperature and of the magnetic field on the resistivity of the surface. The contribution coming from electron cloud effects has been evaluated for different values of the Secondary Electron Yield of the surface based PyECLOUD build-up simulations.

  16. Motion of a ballistic missile angularly misaligned with the flight path upon entering the atmosphere and its effect upon aerodynamic heating, aerodynamic loads, and miss distance

    Science.gov (United States)

    Allen, Julian H

    1957-01-01

    An analysis is given of the oscillating motion of a ballistic missile which upon entering the atmosphere is angularly misaligned with respect to the flight path. The history of the motion for some example missiles is discussed from the point of view of the effect of the motion on the aerodynamic heating and loading. The miss distance at the target due to misalignment and to small accidental trim angles is treated. The stability problem is also discussed for the case where the missile is tumbling prior to atmospheric entry.

  17. The use of solar simulation systems for producing artificial global radiation for the purpose of determining the heat load of rooms

    Science.gov (United States)

    Kalt, A. C.

    1975-01-01

    Certain climatic tests which require solar and sky radiation were carried out in the laboratory by using simulated global radiation. The advantages of such a method of measurement and the possibilities and limitations resulting from the simulation of global radiation are described. Experiments concerning the thermal load in rooms were conducted in order to test the procedure. In particular, the heat gain through a window with sunshade is discussed, a venetian blind between the panes of a double-glazed window being used in most cases.

  18. Spin echo in synchrotrons

    Science.gov (United States)

    Chao, Alexander W.; Courant, Ernest D.

    2007-01-01

    As a polarized beam is accelerated through a depolarization resonance, its polarization is reduced by a well-defined calculable reduction factor. When the beam subsequently crosses a second resonance, the final beam polarization is considered to be reduced by the product of the two reduction factors corresponding to the two crossings, each calculated independently of the other. This is a good approximation when the spread of spin precession frequency Δνspin of the beam (particularly due to its energy spread) is sufficiently large that the spin precession phases of individual particles smear out completely during the time τ between the two crossings. This approximate picture, however, ignores two spin dynamics effects: an interference-overlap effect and a spin echo effect. This paper is to address these two effects. The interference-overlap effect occurs when Δνspin is too small, or when τ is too short, to complete the smearing process. In this case, the two resonance crossings overlap each other, and the final polarization exhibits constructive or destructive interference patterns depending on the exact value of τ. Typically, the beam’s energy spread is large and this interference-overlap effect does not occur. To study this effect, therefore, it is necessary to reduce the beam energy spread and to consider two resonance crossings very close to each other. The other mechanism, also due to the interplay between two resonance crossings, is spin echo. It turns out that even when the precession phases appear to be completely smeared between the two crossings, there will still be a sudden and short-lived echo signal of beam polarization at a time τ after the second crossing; the magnitude of which can be as large as 57%. This echo signal exists even when the beam has a sizable energy spread and when τ is very large, and could be a sensitive (albeit challenging) way to experimentally test the intricate spin dynamics in a synchrotron. After giving an analysis

  19. Spin Echo in Synchrotrons

    Energy Technology Data Exchange (ETDEWEB)

    Chao, Alexander W.; /SLAC; Courant, Ernest D.; /Brookhaven

    2006-12-01

    As a polarized beam is accelerated through a depolarization resonance, its polarization is reduced by a well-defined calculable reduction factor. When the beam subsequently crosses a second resonance, the final beam polarization is considered to be reduced by the product of the two reduction factors corresponding to the two crossings, each calculated independently of the other. This is a good approximation when the spread of spin precession frequency {Delta}{nu}{sub spin} of the beam (particularly due to its energy spread) is sufficiently large that the spin precession phases of individual particles smear out completely during the time {tau} between the two crossings. This approximate picture, however, ignores two spin dynamics effects: an interference effect and a spin echo effect. This paper is to address these two effects. The interference effect occurs when {Delta}{nu}{sub spin} is too small, or when {tau} is too short, to complete the smearing process. In this case, the two resonance crossings interfere with each other, and the final polarization exhibits constructive or destructive patterns depending on the exact value of {tau}. Typically, the beam's energy spread is large and this interference effect does not occur. To study this effect, therefore, it is necessary to reduce the beam energy spread and to consider two resonance crossings very close to each other. The other mechanism, also due to the interplay between two resonance crossings, is spin echo. It turns out that even when the precession phases appear to be completely smeared between the two crossings, there will still be a sudden and short-lived echo signal of beam polarization at a time {tau} after the second crossing; the magnitude of which can be as large as 57%. This echo signal exists even when the beam has a sizable energy spread and when {tau} is very large, and could be a sensitive (albeit challenging) way to experimentally test the intricate spin dynamics in a synchrotron. After giving

  20. Towards synchrotron-based nanocharacterization

    Science.gov (United States)

    Bleuet, Pierre; Arnaud, Lucile; Biquard, Xavier; Cloetens, Peter; Doyen, Lise; Gergaud, Patrice; Lamontagne, Patrick; Lavayssière, Maylis; Micha, Jean-Sébastien; Renault, Olivier; Rieutord, François; Susini, Jean; Ulrich, Olivier

    2009-09-01

    The advent of 3rd generation synchrotron sources coupled with high efficiency x-ray focusing optics opened new nanocharacterization possibilities. This paper is an overview of synchrotron-based techniques that may be of interest for nanotechnology researchers. Although not exhaustive, it includes a general background of synchrotron principle and main x-ray interactions before addressing nanoimaging possibilities. Three-dimensional (3D) hard x-ray multimodal tomography is now doable that allows producing 3D morphological, chemical and crystalline images with a sub-100 nm resolution. Although the resolution is still limited with respect to electron imaging, it presents attractive features like depth resolution and non-destructive exam. Besides imaging, diffraction also allows strain determination within microstructures and is illustrated here on 100 nm copper lines. Surface analysis is illustrated through X-ray Photoelectron Emission Microscopy (XPEEM).

  1. A novel ultra-high performance liquid chromatography method for the rapid determination of β-lactoglobulin as heat load indicator in commercial milk samples.

    Science.gov (United States)

    Boitz, Lisa I; Fiechter, Gregor; Seifried, Reinhold K; Mayer, Helmut K

    2015-03-20

    The level of undenatured acid-soluble β-lactoglobulin can be used as an indicator to assess the heat load applied to liquid milk, thus further allowing the discrimination between milk originating from different thermal production processes. In this work, a new UHPLC method for the rapid determination of bovine β-lactoglobulin in 1.8min only (total runtime 3min) is presented using simple UV detection at 205nm. Separation selectivity for possibly co-eluting other major whey proteins (bovine serum albumin, lactoferrin, α-lactalbumin, immunoglobulin G) was verified, and the method validated for the analysis of liquid milk samples regarding linearity (20-560μg/mL, R(2)>0.99), instrumentation precision (RSDsESL) milk, quite diverse levels were determined ranging from ∼100 up to 4000mg/L, thus clearly illustrating variable applied heat loads and impacts on the "nativeness" of milk essentially due to the fact that the production technologies used for ESL milk may differ significantly, and are currently not regulated in the EU.

  2. Large-surface-area diamond (111) crystal plates for applications in high-heat-load wavefront-preserving x-ray crystal optics

    CERN Document Server

    Stoupin, S; Butler, J E; Kolyadin, A V; Katrusha, A

    2016-01-01

    We report fabrication and results of high-resolution X-ray topography characterization of diamond single crystal plates with a large surface area (10$\\times$10 mm$^2$) and (111) crystal surface orientation for applications in high-heat-load X-ray crystal optics. The plates were fabricated by laser cutting of the (111) facets of diamond crystals grown using high-pressure high-temperature method. The intrinsic crystal quality of a selected 3$\\times$7~mm$^2$ crystal region of one of the studied samples was found to be suitable for applications in wavefront-preserving high-heat-load crystal optics. The wavefront characterization was performed using sequential X-ray diffraction topography in the pseudo plane wave configuration and data analysis using rocking curve topography. The variation of the rocking curve width and peak position measured with a spatial resolution of 13$\\times$13 $\\mu m^2$ over the selected region were found to be less than one microradian.

  3. Manufacture of thick VPS W coatings on relatively large CuZrCr substrate and its steady high heat load performance

    Energy Technology Data Exchange (ETDEWEB)

    Deng, Chunming, E-mail: denghans@126.com; Liu, Min; Yang, Zhenxiao; Deng, Changguang; Zhou, Kesong; Kuang, Ziqi; Zhang, Jifu

    2014-12-15

    W material is considered as one of potential Plasma Facing Materials (PFMs) for its high melting point, excellent stability at elevated temperature, good thermal conductivity, excellent anti-plasma sputtering and low Tritium retention. Functionally graded W/Cu coating was applied on CuCrZr substrate (250 mm × 120 mm × 30 mm) with compositionally gradient W/Cu as bond coat (0.4–0.6 mm) and 1.5 mm thick W coating as top coat via Vacuum Plasma Spraying (VPS) for continuous deposition of 5 h. Microstructure, chemical composition, porosity and adhesive strength for as sprayed thick W coating on the CuCrZr substrate were characterized by means of SEM, ICP-MS, Mercury Intrusion Porosimeter and tensile strength tester. The steady high heat load (HHL) performance for W/Cu functional gradient coating was evaluated by high energy electron beam. The results showed that thick VPS W coated CuCrZr substrate can withstand the steady high heat load at the electron beam power density of 9 MW/m{sup 2} for 1000 cycles.

  4. Large-surface-area diamond (111) crystal plates for applications in high-heat-load wavefront-preserving X-ray crystal optics.

    Science.gov (United States)

    Stoupin, Stanislav; Antipov, Sergey; Butler, James E; Kolyadin, Alexander V; Katrusha, Andrey

    2016-09-01

    Fabrication and results of high-resolution X-ray topography characterization of diamond single-crystal plates with large surface area (10 mm × 10 mm) and (111) crystal surface orientation for applications in high-heat-load X-ray crystal optics are reported. The plates were fabricated by laser-cutting of the (111) facets of diamond crystals grown using high-pressure high-temperature methods. The intrinsic crystal quality of a selected 3 mm × 7 mm crystal region of one of the studied samples was found to be suitable for applications in wavefront-preserving high-heat-load crystal optics. Wavefront characterization was performed using sequential X-ray diffraction topography in the pseudo plane wave configuration and data analysis using rocking-curve topography. The variations of the rocking-curve width and peak position measured with a spatial resolution of 13 µm × 13 µm over the selected region were found to be less than 1 µrad.

  5. High pressure x-ray diffraction techniques with synchrotron radiation

    Institute of Scientific and Technical Information of China (English)

    刘景

    2016-01-01

    This article summarizes the developments of experimental techniques for high pressure x-ray diffraction (XRD) in diamond anvil cells (DACs) using synchrotron radiation. Basic principles and experimental methods for various diffraction geometry are described, including powder diffraction, single crystal diffraction, radial diffraction, as well as coupling with laser heating system. Resolution in d-spacing of different diffraction modes is discussed. More recent progress, such as extended application of single crystal diffraction for measurements of multigrain and electron density distribution, time-resolved diffraction with dynamic DAC and development of modulated heating techniques are briefl y introduced. The current status of the high pressure beamline at BSRF (Beijing Synchrotron Radiation Facility) and some results are also presented.

  6. Synchrotron radiation and structural proteomics

    CERN Document Server

    Pechkova, Eugenia

    2011-01-01

    This book presents an overview of the current state of research in both synchrotron radiation and structural proteomics from different laboratories worldwide. The book presents recent research results in the most advanced methods of synchrotron radiation analysis, protein micro- and nano crystallography, X-ray scattering and X-ray optics, coherent X-Ray diffraction, and laser cutting and contactless sample manipulation are described in details. The book focuses on biological applications and highlights important aspects such as radiation damage and molecular modeling.

  7. Synchrotron radiation techniques for the characterization of $Nb_{3}Sn$ superconductors

    CERN Document Server

    Scheuerlein, C; Buta, F; Reichert, H; Thilly, L

    2009-01-01

    The high flux of high energy x-rays that can be provided through state-of-the-art high energy synchrotron beam lines has enabled a variety of new experiments with the highly absorbing Nb3Sn superconductors. We report different experiments with Nb3Sn strands that have been conducted at the ID15 High Energy Scattering beam line of the European Synchrotron Radiation Facility (ESRF). Synchrotron x-ray diffraction has been used in order to monitor phase transformations during in-situ reaction heat treatments prior to Nb3Sn formation, and to monitor Nb3Sn growth. Fast synchrotron micro-tomography was applied to study void growth during the reaction heat treatment of Internal Tin strands. The elastic strain in the different phases of fully reacted Nb3Sn composite conductors can be measured by high resolution x-ray diffraction during in-situ tensile tests.

  8. Simulation experiment of interaction of plasma facing materials and transient heat loads in ITER divertor by use of magnetized coaxial plasma gun

    Science.gov (United States)

    Nakatsuka, M.; Ando, K.; Higashi, T.; Kikuchi, Y.; Fukumoto, N.; Nagata, M.

    2009-11-01

    Interaction of plasma facing materials and transient head loads such as type I ELMs is one of the critical issues in ITER divertor. The heat load to the ITER divertor during type I ELMs is estimated to be 0.5-3 MJ/m^2 with a pulse length of 0.1-0.5 ms. We have developed a magnetized coaxial plasma gun (MCPG) for the simulation experiment of transient heat load during type I ELMs in ITER divertor. The MCPG has inner and outer electrodes made of stainless steel 304. In addition, the inner electrode is covered with molybdenum so as to suppress the release of impurities from the electrode during the discharge. The diameters of inner and outer electrodes are 0.06 m and 0.14 m, respectively. The power supply for the MCPG is a capacitor bank (7 kV, 1 mF, 25 kJ). The plasma velocity estimated by the time of flight measurement of the magnetic fields was about 50 km/s, corresponding to the ion energy of 15 eV (H) or 30 eV (D). The absorbed energy density of the plasma stream was measured a calorimeter made of graphite. It was found that the absorbed energy density was 0.9 MJ/m^2 with a pulse width of 0.5 ms at the distance of 100 mm from the inner electrode. In the conference, experimental results of plasma exposure on the plasma facing materials in ITER divertor will be shown.

  9. Crack initiation behavior of notched specimens on heat resistant steel under service type loading at high temperature

    Directory of Open Access Journals (Sweden)

    Lu Cui

    2016-10-01

    Full Text Available Cracks at notches deserve special consideration in the design of steam turbine components. This work is addressed to investigate the crack initiation behavior a 10%Cr rotor steel with the help of notched specimens under service-type loading. A significant drifting down of the peak-values of axial deformation under constant amplitude load was observed. Crack initiation was evaluated with the help of the relationship between irreversible deformation energy and cycle number. Further, metallographic examinations were employed to characterize the superposition of creep and fatigue damage mechanisms. Both Neuber-hypothesis and von Mises equivalent strain at notch root were applied for lifetime prediction. Finally, the effectiveness of both methods is validated by comparing with experimental results

  10. Optical systems for synchrotron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Howells, M.R.

    1985-12-01

    Various fundamental topics which underlie the design and use of optical systems for synchrotron radiation are considered from the viewpoint of linear system theory. These topics include the damped harmonic oscillator, free space propagation of an optical field, electromagnetic theory of optical properties of materials, theory of dispersion, and the Kramers-Kronig relations. 32 refs., 5 figs. (LEW)

  11. DESY: Synchrotron and storage rings

    CERN Multimedia

    1972-01-01

    An improvement programme has been under way for several years at the 7.5 GeV électron synchrotron at DESY. In particular it has been designed to increase the accelerated beam intensity, to achieve better quality of the ejected électron beams and photon beams and to improve machine reliability.

  12. Biological physics and synchrotron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Filhol, J.M.; Chavanne, J. [European Synchrotron Radiation Facility, 38 - Grenoble (France); Weckert, E. [Hasylab at Desy, Hamburg (Germany)] [and others

    2001-07-01

    This conference deals with the applications of synchrotron radiation to current problems in biology and medicine. Seven sessions take stock on the subject: sources and detectors; inelastic scattering and dynamics; muscle diffraction; reaction mechanisms; macromolecular assemblies; medical applications; imaging and spectroscopy. The document presents the papers abstracts. (A.L.B.)

  13. Synchrotron radiation and biomedical imaging

    Energy Technology Data Exchange (ETDEWEB)

    Luccio, A.

    1986-08-01

    In this lecture we describe the characteristics of Synchrotron radiation as a source of X rays. We discuss the properties of SR arc sources, wigglers, undulators and the use of backscattering of laser light. Applications to angiography, X ray microscopy and tomography are reviewed. 16 refs., 23 figs.

  14. Strain response of thermal barrier coatings captured under extreme engine environments through synchrotron X-ray diffraction

    Science.gov (United States)

    Knipe, Kevin; Manero, Albert; Siddiqui, Sanna F.; Meid, Carla; Wischek, Janine; Okasinski, John; Almer, Jonathan; Karlsson, Anette M.; Bartsch, Marion; Raghavan, Seetha

    2014-07-01

    The mechanical behaviour of thermal barrier coatings in operation holds the key to understanding durability of jet engine turbine blades. Here we report the results from experiments that monitor strains in the layers of a coating subjected to thermal gradients and mechanical loads representing extreme engine environments. Hollow cylindrical specimens, with electron beam physical vapour deposited coatings, were tested with internal cooling and external heating under various controlled conditions. High-energy synchrotron X-ray measurements captured the in situ strain response through the depth of each layer, revealing the link between these conditions and the evolution of local strains. Results of this study demonstrate that variations in these conditions create corresponding trends in depth-resolved strains with the largest effects displayed at or near the interface with the bond coat. With larger temperature drops across the coating, significant strain gradients are seen, which can contribute to failure modes occurring within the layer adjacent to the interface.

  15. Thermal and structural finite element analysis of water cooled silicon monochromator for synchrotron radiation comparison of two different cooling schemes

    CERN Document Server

    Artemiev, A I; Busetto, E; Hrdy, J; Mrazek, D; Plesek, I; Savoia, A

    2001-01-01

    The article describes the results of Finite Element Analysis (FEA) of the first Si monochromator crystal distortions due to Synchrotron Radiation (SR) heat load and consequent analysis of the influence of the distortions on a double crystal monochromator performance. Efficiencies of two different cooling schemes are compared. A thin plate of Si crystal is lying on copper cooling support in both cases. There are microchannels inside the cooling support. In the first model the direction of the microchannels is parallel to the diffraction plane. In the second model the direction of the microchannels is perpendicular to the diffraction plane or in other words, it is a conventional cooling scheme. It is shown that the temperature field along the crystal volume is more uniform and more symmetrical in the first model than in the second (conventional) one.

  16. Strain response of thermal barrier coatings captured under extreme engine environments through synchrotron X-ray diffraction.

    Science.gov (United States)

    Knipe, Kevin; Manero, Albert; Siddiqui, Sanna F; Meid, Carla; Wischek, Janine; Okasinski, John; Almer, Jonathan; Karlsson, Anette M; Bartsch, Marion; Raghavan, Seetha

    2014-07-31

    The mechanical behaviour of thermal barrier coatings in operation holds the key to understanding durability of jet engine turbine blades. Here we report the results from experiments that monitor strains in the layers of a coating subjected to thermal gradients and mechanical loads representing extreme engine environments. Hollow cylindrical specimens, with electron beam physical vapour deposited coatings, were tested with internal cooling and external heating under various controlled conditions. High-energy synchrotron X-ray measurements captured the in situ strain response through the depth of each layer, revealing the link between these conditions and the evolution of local strains. Results of this study demonstrate that variations in these conditions create corresponding trends in depth-resolved strains with the largest effects displayed at or near the interface with the bond coat. With larger temperature drops across the coating, significant strain gradients are seen, which can contribute to failure modes occurring within the layer adjacent to the interface.

  17. Measurement of gas species, temperatures, char burnout, and wall heat fluxes in a 200-MW{sub e} lignite-fired boiler at different loads

    Energy Technology Data Exchange (ETDEWEB)

    Li, Zhengqi; Jing, Jianping; Liu, Guangkui; Chen, Zhichao; Liu, Chunlong [School of Energy Science and Engineering, Harbin Institute of Technology, 92, West Dazhi Street, Harbin 150001 (China)

    2010-04-15

    We measured various operational parameters of a 200-MW{sub e}, wall-fired, lignite utility boiler under different loads. The parameters measured were gas temperature, gas species concentration, char burnout, component release rates (C, H and N), furnace temperature, heat flux, and boiler efficiency. Cold air experiments of a single burner were conducted in the laboratory. A double swirl flow pulverized-coal burner has two ring recirculation zones that start in the secondary air region of the burner. With increasing secondary air flow, the air flow axial velocity increases, the maximum values for the radial velocity, tangential velocity, and turbulence intensity all increase, and there are slight increases in the air flow swirl intensity and the recirculation zone size. With increasing load gas, the temperature and CO concentration in the central region of burner decrease, while O{sub 2} concentration, NO{sub x} concentration, char burnout, and component release rates of C, H, and N increase. Pulverized-coal ignites farther into the burner, in the secondary air region. Gas temperature, O{sub 2} concentration, NO{sub x} concentration, char burnout and component release rates of C, H, and N all increase. Furthermore, CO concentration varies slightly and pulverized-coal ignites closer. In the side wall region, gas temperature, O{sub 2} concentration, and NO{sub x} concentration all increase, but CO concentration varies only slightly. In the bottom row burner region the furnace temperature and heat flux increase appreciably, but the increase become more obvious in the middle and top row burner regions and in the burnout region. Compared with a 120-MW{sub e} load, the mean NO{sub x} emission at the air preheater exits for 190-MW{sub e} load increases from 589.5 mg/m{sup 3} (O{sub 2} = 6%) to 794.6 mg/m{sup 3} (O{sub 2} = 6%), and the boiler efficiency increases from 90.73% to 92.45%. (author)

  18. Performance, bioenergetic status, and indicators of oxidative stress of environmentally heat-loaded Holstein cows in response to diets inducing milk fat depression.

    Science.gov (United States)

    Kargar, S; Ghorbani, G R; Fievez, V; Schingoethe, D J

    2015-07-01

    Effects of grain type and dietary oil supplement on production performance, energy balance, metabolic heat production, and markers of liver function of heat-loaded lactating dairy cows were evaluated using 8 multiparous Holstein cows (77.0d in milk) in a duplicated 4×4 Latin square design with a 2×2 factorial arrangement of treatments. Experimental diets contained either ground barley or ground corn supplemented with either fish oil or soybean oil at 2% of dietary dry matter. Mean daily maximum temperature, minimum relative humidity, and maximum temperature-humidity index were 35.3°C, 11.3%, and 77.0, respectively. Dietary treatment did not affect rectal temperature (38.9°C), but respiration rate tended to decrease in cows fed fish oil versus soybean oil. Dry matter intake decreased for the fish oil-supplemented diets (21.1 vs. 24.3kg/d), which was negatively correlated with plasma concentrations of alkaline phosphatase (r=-0.45; n=32) and malondialdehyde (r=-0.26; n=32). Actual milk yield (41.9kg/d) and energy-corrected milk yield (36.6kg/d) were not affected by grain type, whereas feeding fish oil decreased milk yield as compared with soybean oil (40.4 vs. 43.4kg/d). Milk fat depression occurred in all dietary treatments, especially when cows were fed fish oil because of the presence of polyunsaturated FA in the diets. trans-10 C18:1 was negatively correlated with milk fat yield (r=-0.38; n=32). Daily milk cis-9,trans-11 C18:2 secretion was 29.6% less in cows fed barley- versus corn-based diets but 31.8% greater in cows fed fish oil as compared with cows fed soybean oil. Because of a lower dry matter intake, metabolic heat production was decreased in cows fed fish oil relative to cows fed soybean oil. Although feeding fish oil versus soybean oil decreased net energy for both maintenance and lactation, net energy balance remained unchanged across treatments. In vivo plasma lipoperoxidation was greater in cows fed fish oil versus soybean oil, which

  19. Pressure waves in liquid mercury target from pulsed heat loads and the possible way controlling their effects

    Energy Technology Data Exchange (ETDEWEB)

    Ni, L.; Skala, K. [Paul Scherrer Institute, Villingen (Switzerland)

    1996-06-01

    In ESS project liquid metals are selected as the main target for the pulsed spallation neutron source. Since the very high instantaneous energy is deposited on the heavy molten target in a very short period time, pressure waves are generated. They travel through the liquid and cause high stress in the container. Also, additional stress should be considered in the wall which is the result of direct heating of the target window. These dynamic processes were simulated with computational codes with the static response being analized first. The total resulting dynamic wall stress has been found to have exceeded the design stress for the selected container material. Adding a small amount of gas bubbles in the liquid could be a possible way to reduce the pressure waves.

  20. A Multiscale Approach to Deformation and Fracture of Heat-Resistant Steel Under Static and Cyclic Loading

    Directory of Open Access Journals (Sweden)

    Pavlo MARUSCHAK

    2013-03-01

    Full Text Available Regularities of static and cyclic deformation, damage and fracture of heat-resistant steel 25Kh1M1F, based on the approaches of physical mesomechanics and 3D interferometry method, are presented in this paper. The applicability of these techniques for different hierarchy levels of deformation was studied. The investigation of scanning microscope photos was conducted for several dissipative structures, fragmentation of the material, localisation of macrodeformation and subsequent failure on macro- and mesolevel. It is shown that the used modern techniques of experimental analysis are very efficient in understanding deformation and damage evolution in materials.DOI: http://dx.doi.org/10.5755/j01.ms.19.1.3821

  1. Medical Applications of Synchrotron Radiation

    Science.gov (United States)

    Thomlinson, W.

    1991-10-01

    Ever since the first diagnostic x-ray was done in the United States on February 3, 1896, the application of ionizing radiation to the field of medicine has become increasingly important. Both in clinical medicine and basic research the use of x-rays for diagnostic imaging and radiotherapy is now widespread. Radiography, angiography, CAT and PETT scanning, mammography, and nuclear medicine are all examples of technologies developed to image the human anatomy. In therapeutic applications, both external and internal sources of radiation are applied to the battle against cancer. The development of dedicated synchrotron radiation sources has allowed exciting advances to take place in many of these applications. The new sources provide tunable, high-intensity monochromatic beams over a wide range of energies which can be tailored to specific programmatic needs. This paper surveys those areas of medical research in which synchrotron radiation facilities are actively involved.

  2. Medical applications of synchrotron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Thomlinson, W.

    1991-10-01

    Ever since the first diagnostic x-ray was done in the United States on February 3, 1896, the application of ionizing radiation to the field of medicine has become increasingly important. Both in clinical medicine and basic research the use of x-rays for diagnostic imaging and radiotherapy is now widespread. Radiography, angiography, CAT and PETT scanning, mammography, and nuclear medicine are all examples of technologies developed to image the human anatomy. In therapeutic applications, both external and internal sources of radiation are applied to the battle against cancer. The development of dedicated synchrotron radiation sources has allowed exciting advances to take place in many of these applications. The new sources provide tunable, high-intensity monochromatic beams over a wide range of energies which can be tailored to specific programmatic needs. This paper surveys those areas of medical research in which synchrotron radiation facilities are actively involved.

  3. Rapid cycling medical synchrotron and beam delivery system

    Science.gov (United States)

    Peggs, Stephen G [Port Jefferson, NY; Brennan, J Michael [East Northport, NY; Tuozzolo, Joseph E [Sayville, NY; Zaltsman, Alexander [Commack, NY

    2008-10-07

    A medical synchrotron which cycles rapidly in order to accelerate particles for delivery in a beam therapy system. The synchrotron generally includes a radiofrequency (RF) cavity for accelerating the particles as a beam and a plurality of combined function magnets arranged in a ring. Each of the combined function magnets performs two functions. The first function of the combined function magnet is to bend the particle beam along an orbital path around the ring. The second function of the combined function magnet is to focus or defocus the particle beam as it travels around the path. The radiofrequency (RF) cavity is a ferrite loaded cavity adapted for high speed frequency swings for rapid cycling acceleration of the particles.

  4. Electricity use and load management in electricity heated one-family houses from customer and utility perspective; Effekten av effekten - Elanvaendning och laststyrning i elvaermda smaahus ur kund- och foeretagsperspektiv

    Energy Technology Data Exchange (ETDEWEB)

    Sernhed, Kerstin

    2004-11-01

    Until recently, the increase in electricity demand and peak power demand has been met by expansion of the electricity production. Today, due to the deregulation of the electricity market, the production capacity is decreasing. Therefore, there is a national interest in finding solutions to peak problems also on the demand side. In the studies described here (Study 1 and 2) ten households in electrically heated houses were examined. In 1999 the utility equipped their customers with a remote metering system (CustCom) that has an in-built load control component. In Study 1, the load pattern of ten households was examined by using energy diaries combined with frequent meter readings (every five minutes) of the load demand for heating, hot water service and domestic electricity use. Household members kept energy diaries over a four-day period in January 2004, noting time, activities and the use of household appliances that run on electricity. The analysis showed that the use of heat-producing household appliances, e.g. sauna, washing machine and dryer, appliances used for cooking, dishwasher and extra electric heaters, contribute to the household's highest peaks. Turning on the sauna and at the same time using the shower equates to a peak load of 7-9 kW. This, in addition to the use of electricity for heating and lighting along alongside electricity use for refrigerators and freezers, results in some households reaching their main fuse level (roughly 13,8 kW for a main fuse of 20 A). This means that the domestic use of electricity makes up a considerable part of the highest peak loads in a household, but the highest peaks occur together with the use of electricity for heating and hot water. In the second study, Study 2, the households participated in a load control experiment, in which the utility was able to turn on and switch off the heating and hot water systems remotely, using the CustCom system. Heating and water heaters were switched off for periods of 1

  5. Breast tomography with synchrotron radiation

    Science.gov (United States)

    Pani, Silvia; Arfelli, Fulvia; Dreossi, Diego; Montanari, Francesco; Longo, Renata; Olivo, Alessandro; Poropat, Paolo; Zanconati, Fabrizio; Palma, Ludovico D.; Castelli, Edoardo

    2002-05-01

    A feasibility study of breast CT with synchrotron radiation is currently being carried on at Elettra, the Trieste synchrotron radiation facility. Breast CT cannot be implemented easily with conventional radiographic tubes, due to the high dose that would be delivered to the breast by a polychromatic X-ray spectrum. The possibility of tuning the beam energy, available at a synchrotron radiation beamline, allows a significant reduction in the delivered dose, and at the same time the use of monochromatic beams avoids beam hardening artifacts on the reconstructed image. Images of in vitro breast tissue samples have been acquired by means of a high efficiency linear array detector coupled to a VLSI single photon counting readout electronics. The pixel width, determining the pixel size of the reconstructed image, is 200 micrometers , while the pixel height, determining the CT slice thickness, is 300 micrometers . Tomograms have been reconstructed by means of standard filtered backprojection algorithms. Images of normal and pathologic breast tissue samples show a good visibility of glandular structure. The delivered dose was in all cases comparable to the one delivered in clinical planar mammography. Due to the promising results we obtained, in vivo studies are under evaluation.

  6. Radio-frequency triggered heating and drug release using doxorubicin-loaded LSMO nanoparticles for bimodal treatment of breast cancer.

    Science.gov (United States)

    Kulkarni, Vaishnavi M; Bodas, Dhananjay; Dhoble, Deepa; Ghormade, Vandana; Paknikar, Kishore

    2016-09-01

    Radio-frequency responsive nanomaterials combined with drugs for simultaneous hyperthermia and drug delivery are potential anti-cancer agents. In this study, chitosan coated La0.7Sr0.3MnO3 nanoparticles (C-LSMO NPs) were synthesized and characterized by X-ray diffraction, dynamic light scattering, Fourier transform infra red spectroscopy, vibrating sample magnetometer, scanning electron and atomic force microscopy. Under low radio-frequency (365kHz, RF), C-LSMO NPs (90nm) showed good colloidal stability (+22mV), superparamagnetic nature (15.4 emu/g) and heating capacity (57.4W/g SAR value). Chitosan facilitated doxorubicin entrapment (76%) resulted in DC-LSMO NPs that showed drug release upon a 5min RF exposure. MCF-7 and MDA-MB-231 cancer cells responded to a 5min RF exposure in the presence of bimodal DC-LSMO NPs with a significant decrease in viability to 73% and 88% (Pearson correlation, r=1, Pheat shock protein induction, and caspase production triggered apoptotic cell death. Moreover, DC-LSMO NPs successfully restricted the migration of metastatic MDA-MB-231 cancer cells. These data suggest that DC-LSMO NPs are potential bimodal therapeutic agents for cancer treatment and hold promise against disease recurrence and drug resistance.

  7. Short-term forecasts of district heating load and outdoor temperature by use of on-line connected computers; Korttidsprognoser foer fjaerrvaermelast och utetemperatur med on-linekopplade datorer

    Energy Technology Data Exchange (ETDEWEB)

    Malmstroem, B.; Ernfors, P.; Nilsson, Daniel; Vallgren, H. [Chalmers Tekniska Hoegskola, Goeteborg (Sweden). Institutionen foer Energiteknik

    1996-10-01

    In this report the available methods for forecasting weather and district heating load have been studied. A forecast method based on neural networks has been tested against the more common statistical methods. The accuracy of the weather forecasts from the SMHI (Swedish Meteorological and Hydrological Institute) has been estimated. In connection with these tests, the possibilities of improving the forecasts by using on-line connected computers has been analysed. The most important results from the study are: Energy company staff generally look upon the forecasting of district heating load as a problem of such a magnitude that computer support is needed. At the companies where computer calculated forecasts are in use, their accuracy is regarded as quite satisfactory; The interest in computer produced load forecasts among energy company staff is increasing; At present, a sufficient number of commercial suppliers of weather forecasts as well as load forecasts is available to fulfill the needs of energy companies; Forecasts based on neural networks did not attain any precision improvement in comparison to more traditional statistical methods. There may though be other types of neural networks, not tested in this study, that are possibly capable of improving the forecast precision; Forecasts of outdoor temperature and district heating load can be significantly improved through the use of on-line-connected computers supplied with instantaneous measurements of temperature and load. This study shows that a general reduction of the load prediction errors by approximately 15% is attainable. For short time horizons (less than 5 hours), more extensive load prediction error reductions can be reached. For the 1-hour time horizon, the possible reduction amounts to up to 50%. 21 refs, 4 figs, 7 appendices

  8. Fracture toughness of the IEA heat of F82H ferritic/martensitic stainless steel as a function of loading mode

    Energy Technology Data Exchange (ETDEWEB)

    Li, Huaxin; Gelles, D.S. [Pacific Northwest Labs., Richland, WA (United States); Hirth, J.P. [Washington State Univ., Pullman, WA (United States)] [and others

    1997-04-01

    Mode I and mixed-mode I/III fracture toughness tests were performed for the IEA heat of the reduced activation ferritic/martensitic stainless steel F82H at ambient temperature in order to provide comparison with previous measurements on a small heat given a different heat treatment. The results showed that heat to heat variations and heat treatment had negligible consequences on Mode I fracture toughness, but behavior during mixed-mode testing showed unexpected instabilities.

  9. Synchrotron-driven spallation sources

    CERN Document Server

    Bryant, P J

    1996-01-01

    The use of synchrotrons for pulsed neutron spallation sources is an example of scientific and technological spin-off from the accelerator development for particle physics. Accelerator-driven sources provide an alternative to the continuous-flux, nuclear reactors that currently furnish the majority of neutrons for research and development. Although the present demand for neutrons can be adequately met by the existing reactors, this situation is unlikely to continue due to the increasing severity of safety regulations and the declared policies of many countries to close down their reactors within the next decade or so. Since the demand for neutrons as a research tool is, in any case,expected to grow, there has been a corresponding interest in sources that are synchrotron-driven or linac-driven with a pulse compression ring and currently several design studies are being made. These accelerator-driven sources also have the advantage of a time structure with a high peak neutron flux. The basic requirement is for a...

  10. Sirepo for Synchrotron Radiation Workshop

    Energy Technology Data Exchange (ETDEWEB)

    2016-10-25

    Sirepo is an open source framework for cloud computing. The graphical user interface (GUI) for Sirepo, also known as the client, executes in any HTML5 compliant web browser on any computing platform, including tablets. The client is built in JavaScript, making use of the following open source libraries: Bootstrap, which is fundamental for cross-platform web applications; AngularJS, which provides a model–view–controller (MVC) architecture and GUI components; and D3.js, which provides interactive plots and data-driven transformations. The Sirepo server is built on the following Python technologies: Flask, which is a lightweight framework for web development; Jinja, which is a secure and widely used templating language; and Werkzeug, a utility library that is compliant with the WSGI standard. We use Nginx as the HTTP server and proxy, which provides a scalable event-driven architecture. The physics codes supported by Sirepo execute inside a Docker container. One of the codes supported by Sirepo is the Synchrotron Radiation Workshop (SRW). SRW computes synchrotron radiation from relativistic electrons in arbitrary magnetic fields and propagates the radiation wavefronts through optical beamlines. SRW is open source and is primarily supported by Dr. Oleg Chubar of NSLS-II at Brookhaven National Laboratory.

  11. The superconducting proposal for the CS magnet system of FAST: a preliminary analysis of the heat load due to AC losses

    CERN Document Server

    Pompeo, N

    2011-01-01

    FAST (Fusion Advanced Studies Torus), the Italian proposal of a Satellite Facility to ITER, is a compact tokamak (R$_0$ = 1.82 m, a = 0.64 m, triangularity $\\delta$ = 0.4) able to investigate non-linear dynamics effects of $\\alpha$-particle behavior in burning plasmas and to test technical solutions for the first wall/divertor directly relevant for ITER and DEMO. Currently, ENEA is investigating the feasibility of a superconducting solution for the magnet system. This paper focuses on the analysis of the CS (Central Solenoid) magnet thermal behavior. In particular, considering a superconducting solution for the CS which uses the room available in the resistive design and referring to one of the most severe scenario envisaged for FAST, the heat load of the CS winding pack due to AC losses is preliminarily evaluated. The results provide a tentative baseline for the definition of the strand requirements and conductor design, that can be accepted in order to fulfil the design requirements.

  12. Funding problems threaten Middle East's synchrotron

    CERN Multimedia

    McCabe, H

    1999-01-01

    Scientists will tour the Middle East to try to raise support for the Synchrotron radiation for Experimental Science and Applications in the Middle East project. The plan is to dismantle and move a decommissioned synchrotron from Berlin to the Middle East where scientists of any nationality would be able to use it (3 paragraphs).

  13. Synchrotron applications in wood preservation and deterioration

    Science.gov (United States)

    Barbara L. Illman

    2003-01-01

    Several non-intrusive synchrotron techniques are being used to detect and study wood decay. The techniques use high intensity synchrotron-generated X-rays to determine the atomic structure of materials with imaging, diffraction, and absorption. Some of the techniques are X-ray absorption near edge structure (XANES), X-ray fluorescence spectroscopy (XFS), X-ray...

  14. High pressure and synchrotron radiation satellite workshop

    Energy Technology Data Exchange (ETDEWEB)

    Bass, J.; Guignot, N.; Morard, G.; Mezouar, M.; Andrault, D.; Bolfan-Casanova, N.; Sturhahn, W.; Daniel, I.; Reynard, B.; Simionovici, A.; Sanchez Valle, C.; Martinez, I.; Kantor, I.; Dubrovinsky, I.; Mccammon, C.; Dubrovinskaia, N.; Kurnosiv, A.; Kuznetsov, A.; Goncharenko, I.; Loubeyre, P.; Desgreniers, S.; Weck, G.; Yoo, C.S.; Iota, V.; Park, J.; Cynn, H.; Gorelli, F.; Toulemonde, P.; Machon, D.; Merlen, A.; San Miguel, A.; Amboage, M.; Aquilanti, G.; Mathon, O.; Pascarelli, S.; Itie, J.P.; Mcmillan, P.F.; Trapananti, A.; Di Cicco, A.; Panfilis, S. de; Filipponi, A.; Kreisel, J.; Bouvier, P.; Dkhil, B.; Chaabane, B.; Rosner, H.; Koudela, D.; Schwarz, U.; Handestein, A.; Hanfland, M.; Opahle, I.; Koepernik, K.; Kuzmin, M.; Mueller, K.H.; Mydosh, J.; Richter, M.; Hejny, C.; Falconi, S.; Lundegaard, L.F.; Mcmahon, M.I; Loa, I.; Syassen, K.; Wang, X.; Roth, H.; Lorenz, T.; Farber Daniel, I.; Antonangeli Daniele, I.; Krisch, M.; Badro, J.; Fiquet, G.; Occelli, F.; Mao, W.L.; Mao, H.K.; Eng, P.; Kao, C.C.; Shu, J.F.; Hemley, R.J.; Tse, J.S.; Yao, Y.; Deen, P.P.; Paolasini, I.; Braithwaite, D.; Kernavanois, N.; Lapertot, G.; Rupprecht, K.; Leupold, O.; Ponkratz, U.; Wortmann, G.; Beraud, A.; Krisch, M.; Farber, D.; Antonangeli, D.; Aracne, C.; Zarestky, J.L.; Mcqueeney, R.; Mathon, O.; Baudelet, F.; Decremps, F.; Itie, J.P.; Nataf, I.; Pascarelli, S.; Polian, A

    2006-07-01

    The workshop is dedicated to recent advances on science at high pressure at third generation synchrotron sources. A variety of experiments using synchrotron radiation techniques including X-ray diffraction, EXAFS (extended X-ray absorption fine structure), inelastic X-ray scattering, Compton scattering and Moessbauer spectroscopy of crystalline, liquid or amorphous samples, are reported. This document gathers the abstracts of the presentations.

  15. In-situ synchrotron wide-angle X-ray diffraction as a rapid method for cocrystal/salt screening.

    Science.gov (United States)

    Dong, Pin; Lin, Ling; Li, Yongcheng; Huang, Zhengwei; Lang, Tianqun; Wu, Chuanbin; Lu, Ming

    2015-12-30

    The purpose of this work was to explore in-situ synchrotron wide-angle X-ray diffraction (WAXD) as a rapid and accurate tool to screen and monitor the formation of cocrystal/salts during heating. The active pharmaceutical ingredients (caffeine, carbamazepine and lamotrigine) were respectively mixed with the coformer (saccharin), and then heated by the hot stage. Real-time process monitoring was performed using synchrotron WAXD to assess cocrystal formation and subsequently compared to differential scanning calorimetry (DSC) measurements. The effect of heating rates and cocrystal growth behavior were investigated. Synchrotron WAXD was fast and sensitive to detect cocrystal formation with the appearance of characteristic diffraction rings, even at the heating rate of 30°C/min, while DSC curves showed overlapped peaks. Unlike the indirect characterization of DSC on endo/exothermic peaks, synchrotron WAXD can directly and qualitatively determine cocrystal by diffraction peaks. The diffraction intensity-temperature curves and the corresponding first-derivative curves clearly exhibited the growth behavior of cocrystal upon heating, providing useful information to optimize the process temperature of hot melt extrusion to continuously manufacture cocrystal. The study suggests that in-situ synchrotron WAXD could provide a one-step process to screen cocrystal at high efficiency and reveal the details of cocrystal/salts growth behavior.

  16. Carbyne formation by synchrotron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Kaito, C.; Kimura, Y.; Hanamoto, K.; Sasaki, M.; Kimura, S.; Nakada, T.; Saito, Y.; Koike, C.; Nakayama, Y. E-mail: nakayamy@se.ritsumei.ac.jp

    2001-07-21

    Thin carbon films prepared by vacuum evaporation using the arc method were mounted on a standard electron microscope copper grid. They were irradiated by white synchrotron radiation (SR) beam by the use of cylindrical and toroidal mirrors. The irradiated film was examined using a high-resolution electron microscope. {alpha} and {alpha}+{beta} mixture carbyne crystals were grown in round and the elongated shapes. The round crystals were composed of 5-10 nm crystallites of a carbyne form. The elongated crystal grew into a single crystal 100 nm in size. The c-axes of both grown crystals were oblique to the film. The growth of the carbynes was discussed as being the result of nucleation due to graphite microcrystallites formed by SR beam irradiation.

  17. Report of the Synchrotron Radiation Vacuum Workshop

    Energy Technology Data Exchange (ETDEWEB)

    Avery, R.T.

    1984-06-01

    The Synchrotron Radiation Vacuum Workshop was held to consider two vacuum-related problems that bear on the design of storage rings and beam lines for synchrotron radiation facilities. These problems are gas desorption from the vacuum chamber walls and carbon deposition on optical components. Participants surveyed existing knowledge on these topics and recommended studies that should be performed as soon as possible to provide more definitive experimental data on these topics. This data will permit optimization of the final design of the Advanced Light Source (ALS) and its associated beam lines. It also should prove useful for other synchrotron radiation facilities as well.

  18. Experimental demonstration of the induction synchrotron.

    Science.gov (United States)

    Takayama, Ken; Arakida, Yoshio; Dixit, Tanuja; Iwashita, Taiki; Kono, Tadaaki; Nakamura, Eiji; Otsuka, Kazunori; Shimosaki, Yoshito; Torikai, Kota; Wake, Masayoshi

    2007-02-01

    We report an experimental demonstration of the induction synchrotron, the concept of which has been proposed as a future accelerator for the second generation of neutrino factory or hadron collider. The induction synchrotron supports a superbunch and a superbunch permits more charge to be accelerated while observing the constraints of the transverse space-charge limit. By using a newly developed induction acceleration system instead of radio-wave acceleration devices, a single proton bunch injected from the 500 MeV booster ring and captured by the barrier bucket created by the induction step voltages was accelerated to 6 GeV in the KEK proton synchrotron.

  19. Development of a novel method for the exploration of the thermal response of superfluid helium cooled superconducting cables to pulse heat loads

    NARCIS (Netherlands)

    Winkler, T.; Koettig, T.; Weelderen, van R.; Bremer, J.; Brake, ter H.J.M.

    2015-01-01

    Management of transient heat deposition in superconducting magnets and its extraction from the aforementioned is becoming increasingly important to bring high energy particle accelerator performance to higher beam energies and intensities. Precise knowledge of transient heat deposition phenomena in

  20. High pressure x-ray diffraction techniques with synchrotron radiation

    Science.gov (United States)

    Jing, Liu

    2016-07-01

    This article summarizes the developments of experimental techniques for high pressure x-ray diffraction (XRD) in diamond anvil cells (DACs) using synchrotron radiation. Basic principles and experimental methods for various diffraction geometry are described, including powder diffraction, single crystal diffraction, radial diffraction, as well as coupling with laser heating system. Resolution in d-spacing of different diffraction modes is discussed. More recent progress, such as extended application of single crystal diffraction for measurements of multigrain and electron density distribution, time-resolved diffraction with dynamic DAC and development of modulated heating techniques are briefly introduced. The current status of the high pressure beamline at BSRF (Beijing Synchrotron Radiation Facility) and some results are also presented. Project supported by the National Natural Science Foundation of China (Grant Nos. 10875142, 11079040, and 11075175). The 4W2 beamline of BSRF was supported by the Chinese Academy of Sciences (Grant Nos. KJCX2-SW-N20, KJCX2-SW-N03, and SYGNS04).

  1. Molecular photoemission studies using synchrotron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Truesdale, C.M.

    1983-04-01

    The angular distributions of photoelectrons and Auger electrons were measured by electron spectroscopy using synchrotron radiation. The experimental results are compared with theoretical calculations to interpret the electronic behavior of photoionization for molecular systems.

  2. Stanford Synchrotron Radiation Light Source (SSRL)

    Data.gov (United States)

    Federal Laboratory Consortium — The SSRL at SLAC National Accelerator Laboratory was built in 1974 to take and use for synchrotron studies the intense x-ray beams from the SPEAR storage ring that...

  3. Panel backs next-generation synchrotron

    CERN Multimedia

    Service, R F

    1999-01-01

    A key federal panel recommended continued research into development of a fourth-generation synchrotron. It would be capable of creating x-ray pulses billions of times more intense than current designs (1 page).

  4. Solenoid and Synchrotron radiation effects in CLIC

    CERN Document Server

    Dalena, B; Tomás, R; Angal-Kalinin, D

    2010-01-01

    The emission of Synchrotron Radiation in the CLIC BDS is one of the major limitations of the machine performance. An extensive revision of this phenomenon is presented with special emphasis on the Interaction point (IP) solenoid.

  5. National Synchrotron Light Source annual report 1988

    Energy Technology Data Exchange (ETDEWEB)

    Hulbert, S.; Lazarz, N.; Williams, G. (eds.)

    1988-01-01

    This report discusses the experiment done at the National Synchrotron Light Source. Most experiments discussed involves the use of the x-ray beams to study physical properties of solid materials. (LSP)

  6. Fiber structural analysis by synchrotron radiation

    CERN Document Server

    Kojima, J I; Kikutani, T

    2003-01-01

    Topics of fiber structural analysis by synchrotron radiation are explained. There are only three synchrotron radiation facilities in the world, SPring-8 (Super Photon ring-8) in Japan, APS (Advanced Photon Source) in U.S.A. and ESRF (European Synchrotron Radiation Facility) in France. Online measurement of melt spinning process of PET and Nylon6 is explained in detail. Polypropylene and PBO (poly-p-phenylenebenzobisoxazole) was measured by WAXD (Wide Angle X-ray Diffraction)/SAXS (Small Angle X-ray Scattering) at the same time. Some examples of measure of drawing process of fiber are described. The structure formation process of spider's thread was measured. Micro beam of X-ray of synchrotron facility was improved and it attained to 65nm small angle resolving power by 10 mu m beamsize. (S.Y.)

  7. Simulation of synchrotron motion with rf noise

    Energy Technology Data Exchange (ETDEWEB)

    Leemann, B.T.; Forest, E.; Chattopadhyay, S.

    1986-08-01

    The theoretical formulation is described that is behind an algorithm for synchrotron phase-space tracking with rf noise and some preliminary simulation results of bunch diffusion under rf noise obtained by actual tracking.

  8. Precision Calibration of Infrared Synchrotron Radiation Detectors

    CERN Document Server

    Maltsev, A A; Maslova, M V

    2003-01-01

    The technique of calibration of synchrotron radiation precision detectors on a tungsten source based on similarity (close similarity) of character of spectral distributions of synchrotron and thermal radiations is given. The characteristics of various commonly used lamps, used as "standard" ones, are given. The errors of measurements are analyzed. The detectors are intended for absolute measurements of the number of electrons in a ring-shaped bunch.

  9. Modulation of synchrotron radiation by acoustic oscillations

    CERN Document Server

    Mkrtchyan, A R; Kocharyan, L A; Mirzoyan, V K

    1986-01-01

    By means of a quartz single crystal excited by piezoelectric oscillations, the modulation of synchrotron radiation reflected from the quartz planes (1011) is realized for frequencies ranging from 1 Hz to 15 kHz when the Bragg condition is satisfied. The wavelength of synchrotron radiation ranged from 0.3 to 12A. The patterns of modulated beams taken from oscillograph and analyzer screens are shown.

  10. Wakefields in Coherent Synchrotron Radiation

    Science.gov (United States)

    Billinghurst, Brant E.; Bergstrom, J. C.; Baribeau, C.; Batten, T.; Dallin, L.; May, Tim E.; Vogt, J. M.; Wurtz, Ward A.; Warnock, Robert L.; Bizzozero, D. A.; Kramer, S.; Michaelian, K. H.

    2016-06-01

    When the electron bunches in a storage ring are sufficiently short the electrons act coherently producing radiation several orders of magnitude more intense than normal synchrotron radiation. This is referred to as Coherent Syncrotron Radiation (CSR). Due to the potential of CSR to provide a good source of Terahertz radiation for our users, the Canadian Light Source (CLS) has been researching the production and application of CSR. CSR has been produced at the CLS for many years, and has been used for a number of applications. However, resonances that permeate the spectrum at wavenumber intervals of 0.074 cm-1, and are highly stable under changes in the machine setup, have hampered some experiments. Analogous resonances were predicted long ago in an idealized theory. Through experiments and further calculations we elucidate the resonance and wakefield mechanisms in the CLS vacuum chamber. The wakefield is observed directly in the 30-110 GHz range by rf diodes. These results are consistent with observations made by the interferometer in the THz range. Also discussed will be some practical examples of the application of CSR for the study of condensed phase samples using both transmission and Photoacoustic techniques.

  11. Synchrotron radiation from massless charge

    CERN Document Server

    Gal'tsov, D V

    2015-01-01

    Classical radiation power from an accelerated massive charge diverges in the zero-mass limit, while some general arguments suggest that strictly massless charge does not not radiate at all. On the other hand, the regularized classical radiation reaction force, though looking odd, is non-zero and finite. To clarify this controversy, we consider radiation problem in massless scalar quantum electrodynamics in the external magnetic field. In this framework, synchrotron radiation is found to be non-zero, finite, and essentially quantum. Its spectral distribution is calculated using Schwinger's proper time technique for {\\em ab initio} massless particle of zero spin. Provided $E^2\\gg eH$, the maximum in the spectrum is shown to be at $\\hbar \\omega=E/3$, and the average photon energy is $4E/9$. The normalized spectrum is universal, depending neither on $E$ nor on $H$. Quantum nature of radiation makes classical radiation reaction equation meaningless for massless charge. Our results are consistent with the view (sup...

  12. Synchrotron radiation from massless charge

    Directory of Open Access Journals (Sweden)

    D.V. Gal'tsov

    2015-07-01

    Full Text Available Classical radiation power from an accelerated massive charge diverges in the zero-mass limit, while some authors suggest that strictly massless charge does not radiate at all. On the other hand, the regularized classical radiation reaction force, though looking odd, is non-zero and finite. To clarify this controversy, we consider radiation problem in massless scalar quantum electrodynamics in the external magnetic field. In this framework, synchrotron radiation is found to be non-zero, finite, and essentially quantum. Its spectral distribution is calculated using Schwinger's proper time technique for ab initio massless particle of zero spin. Provided E2≫eH, the maximum in the spectrum is shown to be at ħω=E/3, and the average photon energy is 4E/9. The normalized spectrum is universal, depending neither on E nor on H. Quantum nature of radiation makes classical radiation reaction equation meaningless for massless charge. Classical theory is reliable only as providing the low-frequency part of the true quantum radiation spectrum.

  13. Space heat flux simulation and programmable load for thermal test of space optical remote sensor%空间光学遥感器热试验外热流模拟及程控实现

    Institute of Scientific and Technical Information of China (English)

    关奉伟; 刘巨; 于善猛; 黄勇; 崔抗

    2014-01-01

    The whole process of space heat flux analysis, heat flux simulation and programmable load for ther-mal test is expatiated for a given space optical remote sensor working in sun-synchronous orbit.Firstly, space heat flux simulation process of space optical remote sensor is summarized.Secondly, calculation methods of solar radiation, earth albedo and earth infrared radiation are introduced.Thirdly, the space total absorbed heat flux for the given space optical remote sensor is calculated, and the average heat flux of the sunlit area and the shaded area is gained.Finally, the space heat flux simulation method and tactic of thermal test are confirmed, and open-loop control program of programmable power is written using LabVIEW language , and space transient heat loads of thermal test are accurately applied.The results of test indicate that the deviations of applied heat load are within ±2.5%, and the deviations which can meet the requirements of thermal test.%以某太阳同步轨道空间光学遥感器为例,阐述了空间外热流分析计算、热平衡试验外热流模拟以及外热流程控加载的全过程。首先,总结了空间光学遥感器外热流模拟的完整流程。其次,简要介绍了太阳辐射、地球反照、地球红外辐射三种空间外热流的计算方法。然后,对该空间遥感器进行了空间综合吸收外热流计算,获得了阳照区及阴影区外热流平均值。最后,确定了热平衡试验外热流的模拟方法和策略,利用LabVIEW语言编写了程控电源开环控制程序,实现了热试验外热流的准确加载。试验结果表明,外热流值加载偏差在±2.5%以内,满足热平衡试验要求。

  14. Spatial Coherence of Synchrotron Radiation

    Energy Technology Data Exchange (ETDEWEB)

    Marchesini, S; Coisson, R

    2003-10-30

    Synchrotron Radiation (SR) has been widely used since the 80's as a tool for many applications of UV, soft X rays and hard X rays in condensed matter physics, chemistry and biology. The evolution of SR sources towards higher brightness has led to the design of low-emittance electron storage rings (emittance is the product of beam size and divergence), and the development of special source magnetic structures, as undulators. This means that more and more photons are available on a narrow bandwidth and on a small collimated beam; in other words there is the possibility of getting a high power in a coherent beam. In most applications, a monochromator is used, and the temporal coherence of the light is given by the monochromator bandwidth. With smaller and smaller sources, even without the use of collimators, the spatial coherence of the light has become appreciable, first in the UV and soft X ray range, and then also with hard X rays. This has made possible new or improved experiments in interferometry, microscopy, holography, correlation spectroscopy, etc. In view of these recent possibilities and applications, it is useful to review some basic concepts about spatial coherence of SR, and its measurement and applications. In particular we show how the spatial coherence properties of the radiation in the far field can be calculated with simple operations from the single-electron amplitude and the electron beam angular and position spreads. The gaussian approximation will be studied in detail for a discussion of the properties of the far field mutual coherence and the estimate of the coherence widths, and the comparison with the VanCittert-Zernike limit.

  15. Synchrotron based spallation neutron source concepts

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Y.

    1998-07-01

    During the past 20 years, rapid-cycling synchrotrons (RCS) have been used very productively to generate short-pulse thermal neutron beams for neutron scattering research by materials science communities in Japan (KENS), the UK (ISIS) and the US (IPNS). The most powerful source in existence, ISIS in the UK, delivers a 160-kW proton beam to a neutron-generating target. Several recently proposed facilities require proton beams in the MW range to produce intense short-pulse neutron beams. In some proposals, a linear accelerator provides the beam power and an accumulator ring compresses the pulse length to the required {approx} 1 {micro}s. In others, RCS technology provides the bulk of the beam power and compresses the pulse length. Some synchrotron-based proposals achieve the desired beam power by combining two or more synchrotrons of the same energy, and others propose a combination of lower and higher energy synchrotrons. This paper presents the rationale for using RCS technology, and a discussion of the advantages and disadvantages of synchrotron-based spallation sources.

  16. Synchrotron radiation applications in medical research

    Energy Technology Data Exchange (ETDEWEB)

    Thomlinson, W.

    1995-12-31

    The medical projects employing synchrotron radiation as discussed in this paper are, for the most part, still in their infancies and no one can predict the direction in which they will develop. Both the basic research and applied medical programs are sure to be advanced at the new facilities coming on line, especially the ESRF and Spring- 8. However, success is not guaranteed. There is a lot of competition from advances in conventional imaging with the development of digital angiography, computed tomography, functional magnetic resonance imaging and ultrasound. The synchrotron programs will have to provide significant advantages over these modalities in order to be accepted by the medical profession. Advances in image processing and potentially the development of compact sources will be required in order to move the synchrotron developed imaging technologies into the clinical world. In any event, it can be expected that the images produced by the synchrotron technologies will establish ``gold standards`` to be targeted by conventional modalities. A lot more work needs to be done in order to bring synchrotron radiation therapy and surgery to the level of human studies and, subsequently, to clinical applications.

  17. Heating load of envelope and energy efficiency correction factor for orientation of civil buildings%民用建筑围护结构负荷与节能朝向修正率

    Institute of Scientific and Technical Information of China (English)

    刘艳峰; 王登甲; 张薇

    2013-01-01

    In the current heating design standard, the value scope of the correction factor for orientation of building envelope heating loads is rather large, and it cannot reflect the differences of solar radiation intensities in various regions which results in that the design calculation results fail to match the respect practical situation. The related energy efficiency design standard does not take the orientation correction into account. Synthetically considering graded solar energy zoning and building thermotechnical design zoning standard, chooses the representative city of every region. Calculates and obtains heating load and energy efficiency correction factors for orientation for wider and more accurate application.%在现行暖通设计规范中,围护结构负荷朝向修正率取值范围较大,且无法体现太阳辐照度地区差异引起的差别,导致不同地区设计计算结果与实际朝向负荷不相符.相关节能设计标准中亦未考虑朝向修正.综合考虑太阳能热能等级分区和建筑热工设计分区划分标准,选取典型城市,计算得到了适用范围广、较准确的负荷朝向修正率和节能朝向修正率.

  18. Fifth school on Magnetism and Synchrotron Radiation

    CERN Document Server

    Beaurepaire, Eric; Scheurer, Fabrice; Kappler, Jean-Paul; Magnetism and Synchrotron Radiation : New Trends

    2010-01-01

    Advances in the synthesis of new materials with often complex, nano-scaled structures require increasingly sophisticated experimental techniques that can probe the electronic states, the atomic magnetic moments and the magnetic microstructures responsible for the properties of these materials. At the same time, progress in synchrotron radiation techniques has ensured that these light sources remain a key tool of investigation, e.g. synchrotron radiation sources of the third generation are able to support magnetic imaging on a sub-micrometer scale. With the Fifth Mittelwihr School on Magnetism and Synchrotron Radiation the tradition of teaching the state-of-the-art on modern research developments continues and is expressed through the present set of extensive lectures provided in this volume. While primarily aimed at postgraduate students and newcomers to the field, this volume will also benefit researchers and lecturers actively working in the field.

  19. Paraxial Green's functions in Synchrotron Radiation theory

    CERN Document Server

    Geloni, G; Schneidmiller, E; Yurkov, M; Geloni, Gianluca; Saldin, Evgeni; Schneidmiller, Evgeni; Yurkov, Mikhail

    2005-01-01

    This work contains a systematic treatment of single particle Synchrotron Radiation and some application to realistic beams with given cross section area, divergence and energy spread. Standard theory relies on several approximations whose applicability limits and accuracy are often forgotten. We begin remarking that on the one hand, a paraxial approximation can always be applied without loss of generality and with ultra relativistic accuracy. On the other hand, dominance of the acceleration field over the velocity part in the Lienard-Wiechert expressions is not always granted and constitutes a separate assumption, whose applicability is discussed. Treating Synchrotron Radiation in paraxial approximation we derive the equation for the slow varying envelope function of the Fourier components of the electric field vector. Calculations of Synchrotron Radiation properties performed by others showed that the phase of the Fourier components of the electric field vector differs from the phase of a virtual point sourc...

  20. Chemical applications of synchrotron radiation: Workshop report

    Energy Technology Data Exchange (ETDEWEB)

    1989-04-01

    The most recent in a series of topical meetings for Advanced Photon Source user subgroups, the Workshop on Chemical Applications of Synchrotron Radiation (held at Argonne National Laboratory, October 3-4, 1988) dealt with surfaces and kinetics, spectroscopy, small-angle scattering, diffraction, and topography and imaging. The primary objectives were to provide an educational resource for the chemistry community on the scientific research being conducted at existing synchrotron sources and to indicate some of the unique opportunities that will be made available with the Advanced Photon Source. The workshop organizers were also interested in gauging the interest of chemists in the field of synchrotron radiation. Interest expressed at the meeting has led to initial steps toward formation of a Chemistry Users Group at the APS. Individual projects are processed separately for the data bases.

  1. Coherent Synchrotron Radiation: Theory and Simulations.

    Energy Technology Data Exchange (ETDEWEB)

    Novokhatski, Alexander; /SLAC

    2012-03-29

    The physics of coherent synchrotron radiation (CSR) emitted by ultra-relativistic electron bunches, known since the last century, has become increasingly important with the development of high peak current free electron lasers and shorter bunch lengths in storage rings. Coherent radiation can be described as a low frequency part of the familiar synchrotron radiation in bending magnets. As this part is independent of the electron energy, the fields of different electrons of a short bunch can be in phase and the total power of the radiation will be quadratic with the number of electrons. Naturally the frequency spectrum of the longitudinal electron distribution in a bunch is of the same importance as the overall electron bunch length. The interest in the utilization of high power radiation from the terahertz and far infrared region in the field of chemical, physical and biological processes has led synchrotron radiation facilities to pay more attention to the production of coherent radiation. Several laboratories have proposed the construction of a facility wholly dedicated to terahertz production using the coherent radiation in bending magnets initiated by the longitudinal instabilities in the ring. Existing synchrotron radiation facilities also consider such a possibility among their future plans. There is a beautiful introduction to CSR in the 'ICFA Beam Dynamics Newsletter' N 35 (Editor C. Biscari). In this paper we recall the basic properties of CSR from the theory and what new effects, we can get from the precise simulations of the coherent radiation using numerical solutions of Maxwell's equations. In particular, transverse variation of the particle energy loss in a bunch, discovered in these simulations, explains the slice emittance growth in bending magnets of the bunch compressors and transverse de-coherence in undulators. CSR may play same the role as the effect of quantum fluctuations of synchrotron radiation in damping rings. It can limit

  2. Poly(ε-caprolactone films reinforced with chlorhexidine loaded electrospun polylactide microfibers

    Directory of Open Access Journals (Sweden)

    Y. Marquez

    2017-09-01

    Full Text Available Poly(ε-caprolactone (PCL films reinforced with polylactide (PLA microfibers were prepared by two methodologies: a melt pressing of an electrospun PLA mat between two PCL films, and b melt pressing of a co-electrospun mat composed of PLA microfibers and PCL nanofibers. Electrospinning conditions were selected for each polymer to obtain films loaded with 10, 20 and 30 wt% of PLA. Thermal and mechanical properties varied depending on the preparation method. Thus, PLA crystallinity was higher when films were obtained by the co-electrospinning process, as revealed from DSC and synchrotron X-ray diffraction data since cold crystallization of the highly oriented PLA microfibers was favored in the subsequent heating run when they were in close contact with PCL nanofibers. Samples obtained by co-electrospinning also showed higher mechanical properties (e.g. Young modulus with increasing PLA load. In this case, fracture surfaces showed significant interactions between fibers and the PCL matrix and decreased fiber pull-out. All fabrics were also loaded with chlorhexidine (CHX as a hydrophilic bactericide agent. A delayed release was observed when the drug was only loaded into the electrospun PLA microfibers, and diffusion varied with the method of preparation. In all cases, samples had a clear bactericide effect against Gram positive and Gram negative bacteria. Nevertheless, the protective effect was slightly lower when CHX was only loaded in the reinforcing PLA microfibers.

  3. Comparison of the impact of six heat-load management strategies on thermal responses and milk production of feed-pad and pasture fed dairy cows in a subtropical environment

    Science.gov (United States)

    Davison, T. M.; Jonsson, N. N.; Mayer, D. G.; Gaughan, J. B.; Ehrlich, W. K.; McGowan, M. R.

    2016-05-01

    Exposure to hot environments affects milk yield (MY) and milk composition of pasture and feed-pad fed dairy cows in subtropical regions. This study was undertaken during summer to compare MY and physiology of cows exposed to six heat-load management treatments. Seventy-eight Holstein-Friesian cows were blocked by season of calving, parity, milk yield, BW, and milk protein (%) and milk fat (%) measured in 2 weeks prior to the start of the study. Within blocks, cows were randomly allocated to one of the following treatments: open-sided iron roofed day pen adjacent to dairy (CID) + sprinklers (SP); CID only; non-shaded pen adjacent to dairy + SP (NSD + SP); open-sided shade cloth roofed day pen adjacent to dairy (SCD); NSD + sprinkler (sprinkler on for 45 min at 1100 h if mean respiration rate >80 breaths per minute (NSD + WSP)); open-sided shade cloth roofed structure over feed bunk in paddock + 1 km walk to and from the dairy (SCP + WLK). Sprinklers for CID + SP and NSD + SP cycled 2 min on, 12 min off when ambient temperature >26°C. The highest milk yields were in the CID + SP and CID treatments (23.9 L cow-1 day-1), intermediate for NSD + SP, SCD and SCP + WLK (22.4 L cow-1 day-1), and lowest for NSD + WSP (21.3 L cow-1 day-1) (P data were collected on site at 10-min intervals, and from these, THI was calculated. Nonlinear regression modelling of MY × THI and heat-load management treatment demonstrated that cows in CID + SP showed no decline in MY out to a THI break point value of 83.2, whereas the pooled MY of the other treatments declined when THI >80.7. A combination of iron roof shade plus water sprinkling throughout the day provided the most effective control of heat load.

  4. 12 Experimental Techniques at Synchrotron Lightsource Beamlines

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Peter L [US Department of Energy Office of Science Office Basic Energy Sciences; Rhyne, James J [US Department of Energy Office of Science Office of Basic Energy Sciences

    2015-01-01

    The unique properties of synchrotron radiation are its continuous spectrum, high flux and brightness, and high coherence, which make it an indispensable tool in the exploration of matter. The wavelengths of the emitted photons span a range of dimensions from the atomic level to biological cells, thereby providing incisive probes for advanced research in materials science, physical and chemical sciences, metrology, geosciences, environmental sciences, biosciences, medical sciences, and pharmaceutical sciences. The features of synchrotron radiation are especially well matched to the needs of nanoscience.

  5. Aharonov-Bohm Effect in Synchrotron Radiation

    CERN Document Server

    Bagrov, V G; Levin, A; Tlyachev, V B

    2001-01-01

    Synchrotron radiation of a charged particle in a constant uniform magnetic field and in the presence of the Aharonov-Bohm solenoid field is studied in the frame of the relativistic quantum theory. First, to this end exact solutions of the Klein-Gordon and Dirac equations are found. Using such solutions, all characteristics of one photon spontaneous irradiation, such as its intensity and angular distribution and polarization were calculated and analyzed. It is shown that usual spectrum of the synchrotron radiation is essentially affected by the presence of the solenoid (the Aharonov-Bohm effect). We believe that this deformation may be observed by spectroscopic methods of measurement. It is shown that

  6. Update on synchrotron radiation TXRF: New results

    Energy Technology Data Exchange (ETDEWEB)

    Brennan, S.; Pianetta, P.; Ghosh, S. [Stanford Univ., CA (United States). Stanford Synchrotron Radiation Lab.] [and others

    1998-12-31

    Synchrotron-based total-reflection x-ray fluorescence (SR-TXRF) has been developed as a leading technique for measuring wafer cleanliness. It holds advantages over other techniques in that it is non-destructive and allows mapping of the surface. The highest sensitivity observed thus far is 3 {times} 10{sup 8} atoms/cm{sup 2} ({approx} 3fg) for 1,000 second count time. Several applications of SR-TXRF are presented which take advantage of the energy tunability of the synchrotron source or the mapping capability.

  7. Compact synchrotron light source of the HSRC.

    Science.gov (United States)

    Yoshida, K; Takayama, T; Hori, T

    1998-05-01

    A 700 MeV synchrotron radiation source optimized in order to be incorporated in the university laboratory is under commissioning at Hiroshima University. The storage ring is of a racetrack type with two long straight sections for installing undulators. The bending field is as strong as 2.7 T, produced by normal-conducting magnet technology, and delivers synchrotron radiation with a critical wavelength of 1.42 nm. The strong magnetic field also enables a low-energy injection scheme to be employed owing to the fast radiation damping. A 150 MeV microtron has been adopted as the injector.

  8. New Pulsed Orbit Bump Magnets for the Fermilab Booster Synchrotron

    CERN Document Server

    Lackey, James; John, Carson; Kashikhin, Vladimir; Makarov, Alexander; Prebys, Eric

    2005-01-01

    The beam from the Fermilab Linac is injected onto a bump in the closed orbit of the Booster Synchrotron where a carbon foil strips the electrons from the Linac’s negative ion hydrogen beam. Although the Booster itself runs at 15Hz, heat dissipation in the orbit bump magnets has been one limitation to the fraction of the cycles that can be used for beam. New, 0.28T pulsed window frame dipole magnets have been constructed that will fit into the same space as the old ones, run at the full repetition rate of the Booster, and provide a larger bump to allow a cleaner injection orbit. The new magnets use a high saturation flux density Ni-Zn ferrite in the yoke rather than laminated steel. The presented magnetic design includes two and three dimensional magnetic field calculations with eddy currents and ferrite nonlinear effects.

  9. Optimisation of load control

    Energy Technology Data Exchange (ETDEWEB)

    Koponen, P. [VTT Energy, Espoo (Finland)

    1998-08-01

    Electricity cannot be stored in large quantities. That is why the electricity supply and consumption are always almost equal in large power supply systems. If this balance were disturbed beyond stability, the system or a part of it would collapse until a new stable equilibrium is reached. The balance between supply and consumption is mainly maintained by controlling the power production, but also the electricity consumption or, in other words, the load is controlled. Controlling the load of the power supply system is important, if easily controllable power production capacity is limited. Temporary shortage of capacity causes high peaks in the energy price in the electricity market. Load control either reduces the electricity consumption during peak consumption and peak price or moves electricity consumption to some other time. The project Optimisation of Load Control is a part of the EDISON research program for distribution automation. The following areas were studied: Optimization of space heating and ventilation, when electricity price is time variable, load control model in power purchase optimization, optimization of direct load control sequences, interaction between load control optimization and power purchase optimization, literature on load control, optimization methods and field tests and response models of direct load control and the effects of the electricity market deregulation on load control. An overview of the main results is given in this chapter

  10. Studies of protein structure in solution and protein folding using synchrotron small-angle x-ray scattering

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Lingling [Stanford Univ., CA (United States)

    1996-04-01

    Synchrotron small angle x-ray scattering (SAXS) has been applied to the structural study of several biological systems, including the nitrogenase complex, the heat shock cognate protein (hsc70), and lysozyme folding. The structural information revealed from the SAXS experiments is complementary to information obtained by other physical and biochemical methods, and adds to our knowledge and understanding of these systems.

  11. Optimized beamline design for macromolecular crystallography at the Cornell High Energy Synchrotron Source (CHESS) (abstract)

    Science.gov (United States)

    Schildkamp, Wilfried; Bilderback, Donald; Moffat, Keith

    1989-07-01

    The A1 station on the CHESS wiggler beamline has been the workhorse for most macromolecular crystallographic experiments. This station is equipped with a fixed energy focusing germanium (111) monochromator and a focusing total reflection mirror. Our macromolecular crystallographers made full use of the high flux of more than 1012 photons/s/mm2 and the stable beam conditions, both in position and energy resolution. As a result, the A1 station was heavily oversubscribed. CHESS is presently expanding its capabilities and a new diffraction station for macromolecular crystallography is under construction. This beamline will be powered by a 24-pole hybrid permanent magnet wiggler with a critical energy of 25 keV. A focusing monochromator, which handles a specific heat load of 10 W/mm2, will have a range of tunability which covers all relevant absorption edges from 7 to 15 keV using a Ge(111) crystal. The energy resolution and the focusing properties remain constant within a factor of 2 over the entire tunability range. We expect a brilliance of about 1013 photons/s/mm2/mrad2/0.1% bandpass. The diffraction station will be equipped with an oscillation camera which can be used with x-ray film of 5×5 or 8×10 in. size or alternatively with Kodak storage phosphors. A wide variety of clamp-on accessories, like crystal coolers, fast shutters, helium pathways, polarimeter, etc. are available. The station will contain a beampipe system, which can also be used for small angle scattering experiments with sample-to-detector distances of up to 3000 mm. The entire diffraction station, its control area, a biological preparation area, and a darkroom are to be embedded in a biological safety containment of the level BL3. This will allow diffraction studies of virulent strains of viruses and other biohazards, which could not previously be studied at synchrotron radiation sources before without causing major disruption to the normal laboratory procedure.

  12. Optimal usage of low temperature heat sources to supply district heating by heat pumps

    DEFF Research Database (Denmark)

    Pieper, Henrik; Ommen, Torben Schmidt; Markussen, Wiebke Brix

    2017-01-01

    This paper presents a theoretical study on the optimal usage of different low temperature heat sources to supply district heating by heat pumps. The study is based on data for the Copenhagen region. The heat sources were prioritized based on the coefficient of performance calculated for each hour....... Groundwater, seawater and air heat sources were compared with each other as well as to a scenario consisting of a combination of these heat sources. In addition, base load and peak load units were included. Characteristic parameters were the coefficient of performance, the number of full load hours...

  13. Investigation of a P-96 heat-recovery boiler used as part of the PGU-450T power unit at the Kaliningrad TETs-2 cogeneration station in the course of perfecting the starting and shutdown operations and during running with base loads

    Science.gov (United States)

    Lepaev, P. A.; Shtan', T. P.; Glusker, B. N.; Pashnin, L. V.; Konovalov, P. S.

    2007-09-01

    Results from operational tests carried out on the pilot P-96 heat-recovery boiler of the PGU-450T power unit at the Kaliningrad TETs-2 cogeneration station are presented. Technologies of starting and shutting down the boiler from different thermal states and peculiarities of its operating conditions in the load controlled range are considered. Specific features pertinent to the operation of a horizontal heat-recovery boiler with natural circulation of working medium in the evaporation heating surfaces are established.

  14. Synchrotron IR spectromicroscopy: chemistry of living cells.

    Science.gov (United States)

    Holman, Hoi-Ying N; Bechtel, Hans A; Hao, Zhao; Martin, Michael C

    2010-11-01

    Advanced analytical capabilities of synchrotron IR spectromicroscopy meet the demands of modern biological research for studying molecular reactions in individual living cells. (To listen to a podcast about this article, please go to the Analytical Chemistry multimedia page at pubs.acs.org/page/ancham/audio/index.html.).

  15. Polymer research and synchrotron radiation perspectives

    NARCIS (Netherlands)

    Portale, Giuseppe; Hermida-Merino, Daniel; Bras, Wim

    2016-01-01

    The developments in synchrotron radiation based polymer research have been profound over the last two decades. Not only have many more beamlines suitable for soft condensed matter research become available since the pioneering days but also the technical developments with respect to X-ray beam quali

  16. Wellcome Trust backs Rutherford to host synchrotron

    CERN Multimedia

    Leder, N

    1999-01-01

    The Wellcome Trust has stated its preference for the site of the new Anglo-French synchrotron to be at RAL in Oxfordshire. But the statement coincides with an announcement from the UK government that a decision on the location of 'Diamond' will be delayed to allow two new reports on the canditate sites to be commissioned (1/2 page).

  17. Optimization on Synchrotron Radiation Lattice of BEPCⅡ

    Institute of Scientific and Technical Information of China (English)

    SUN Yi-Peng; GAO Jie; GUO Zhi-Yu

    2007-01-01

    @@ The Beijing Electron and Positron Collider H (BEPCⅡ) is a double ring electron-positron collider, which can also be used as a synchrotron radiation (SR) light source. Since the BEPCⅡ will start commissioning with SR mode in November 2006, it is essential to have a satisfying SR lattice.

  18. Laboratory source of synchrotron radiation: TROLL-2

    Science.gov (United States)

    Anevsky, S. I.; Vernyi, A. E.; Panasjuk, V. S.; Khromchenko, V. B.

    1987-11-01

    A laboratory synchrotron radiation (SR) source TROLL-2 is described. Its main parameters are as follows: the energy of the accelerated particles = 24 MeV; the orbit radius = 20 mm; the SR pulse half-width = 2 ms, the maximum spectral radiant power (at λ = 350 nm) = 1.2×10 6 W/m.

  19. Assessing noise sources at synchrotron infrared ports.

    Science.gov (United States)

    Lerch, Ph; Dumas, P; Schilcher, T; Nadji, A; Luedeke, A; Hubert, N; Cassinari, L; Boege, M; Denard, J-C; Stingelin, L; Nadolski, L; Garvey, T; Albert, S; Gough, Ch; Quack, M; Wambach, J; Dehler, M; Filhol, J-M

    2012-01-01

    Today, the vast majority of electron storage rings delivering synchrotron radiation for general user operation offer a dedicated infrared port. There is growing interest expressed by various scientific communities to exploit the mid-IR emission in microspectroscopy, as well as the far infrared (also called THz) range for spectroscopy. Compared with a thermal (laboratory-based source), IR synchrotron radiation sources offer enhanced brilliance of about two to three orders of magnitude in the mid-IR energy range, and enhanced flux and brilliance in the far-IR energy range. Synchrotron radiation also has a unique combination of a broad wavelength band together with a well defined time structure. Thermal sources (globar, mercury filament) have excellent stability. Because the sampling rate of a typical IR Fourier-transform spectroscopy experiment is in the kHz range (depending on the bandwidth of the detector), instabilities of various origins present in synchrotron radiation sources play a crucial role. Noise recordings at two different IR ports located at the Swiss Light Source and SOLEIL (France), under conditions relevant to real experiments, are discussed. The lowest electron beam fluctuations detectable in IR spectra have been quantified and are shown to be much smaller than what is routinely recorded by beam-position monitors.

  20. Target particle and heat loads in low-triangularity L-mode plasmas in JET with carbon and beryllium/tungsten walls

    NARCIS (Netherlands)

    Groth, M.; Brezinsek, S.; Belo, P.; Corrigan, G.; Harting, D.; Wiesen, S.; Beurskens, M. N. A.; Brix, M.; Clever, M.; Coenen, J. W.; Eich, T.; Flanagan, J.; Giroud, C.; Huber, A.; Jachmich, S.; Kruezi, U.; Lehnen, M.; Lowry, C.; Maggi, C. F.; Marsen, S.; Meigs, A. G.; Sergienko, G.; Sieglin, B.; Silva, C.; Sirinelli, A.; Stamp, M. F.; van Rooij, G. J.

    2013-01-01

    Divertor radiation profiles, and power and particle fluxes to the target have been measured in attached \\{JET\\} L-mode plasmas with carbon and beryllium/tungsten wall materials. In the beryllium/tungsten configuration, factors of 2–3 higher power loads and peak temperatures at the low field side tar

  1. Fracture mechanics by three-dimensional crack-tip synchrotron X-ray microscopy.

    Science.gov (United States)

    Withers, P J

    2015-03-06

    To better understand the relationship between the nucleation and growth of defects and the local stresses and phase changes that cause them, we need both imaging and stress mapping. Here, we explore how this can be achieved by bringing together synchrotron X-ray diffraction and tomographic imaging. Conventionally, these are undertaken on separate synchrotron beamlines; however, instruments capable of both imaging and diffraction are beginning to emerge, such as ID15 at the European Synchrotron Radiation Facility and JEEP at the Diamond Light Source. This review explores the concept of three-dimensional crack-tip X-ray microscopy, bringing them together to probe the crack-tip behaviour under realistic environmental and loading conditions and to extract quantitative fracture mechanics information about the local crack-tip environment. X-ray diffraction provides information about the crack-tip stress field, phase transformations, plastic zone and crack-face tractions and forces. Time-lapse CT, besides providing information about the three-dimensional nature of the crack and its local growth rate, can also provide information as to the activation of extrinsic toughening mechanisms such as crack deflection, crack-tip zone shielding, crack bridging and crack closure. It is shown how crack-tip microscopy allows a quantitative measure of the crack-tip driving force via the stress intensity factor or the crack-tip opening displacement. Finally, further opportunities for synchrotron X-ray microscopy are explored.

  2. New heating load calculation in practice. DIN 4701 vs. DIN EN 12831; Neue Heizlastberechnung in der Praxis. DIN 4701 vs. DIN EN 12831

    Energy Technology Data Exchange (ETDEWEB)

    Kroeber, C. [Rehau-Akademie Bau, Erlangen (Germany)

    2004-09-15

    DIN EN 12831 is the most controversial technical standard that ever was. The contribution shows the changes from DIN 4701 and their consequences on heating systems and heating grids. (orig.) [German] Wie keine andere Norm, die in den letzten Jahren im Hinblick auf die europaeische Harmonisierung eingefuehrt wurde, sorgt die Heizlastberechnung nach DIN EN 12831 fuer reichlich Gespraechsstoff. In folgendem Beitrag wird beschrieben, welche Veraenderungen im Vergleich zur Waermebedarfsberechnung nach DIN 4701 auftreten und wie sie sich auf die Heizsysteme und Waermeerzeugungsanlagen auswirken. (orig.)

  3. Dipole magnet of synchrotron source for national synchrotron centre of Ukraine

    CERN Document Server

    Gladkikh, P I; Muratov, V I; Peev, F A

    2001-01-01

    The paper contains the revised design of a dipole magnet for a synchrotron radiation source.Usage of such a magnet allows to reach the energy of electrons in a ring up to 1.2 GeV.In paper the result of simulation of a magnet for all modes of operations of a source are shown.The proposed variant of the dipole magnet considerably raises parameters of the synchrotron radiation source.

  4. Assessing and Reducing Miscellaneous Electric Loads (MELs) in Lodging

    Energy Technology Data Exchange (ETDEWEB)

    Rauch, Emily M.

    2011-09-01

    Miscellaneous electric loads (MELs) are the loads outside of a building's core functions of heating, ventilating, air conditioning, lighting, and water heating. This report reviews methods to reduce MELs in lodging.

  5. Remote Synchrotron Light Instrumentation Using Optical Fibers

    Energy Technology Data Exchange (ETDEWEB)

    De Santis, S.; Yin, Y.

    2009-05-04

    By coupling the emitted synchrotron light into an optical fiber, it is possible to transmit the signal at substantial distances from the light port, without the need to use expensive beamlines. This would be especially beneficial in all those cases when the synchrotron is situated in areas not easily access because of their location, or due to high radiation levels. Furthermore, the fiber output can be easily switched, or even shared, between different diagnostic instruments. We present the latest results on the coupling and dispersion measurements performed at the Advanced Light Source in Berkeley. In several cases, coupling synchrotron light into optical fibers can substantially facilitate the use of beam diagnostic instrumentation that measures longitudinal beam properties by detecting synchrotron radiation. It has been discussed in with some detail, how fiberoptics can bring the light at relatively large distances from the accelerator, where a variety of devices can be used to measure beam properties and parameters. Light carried on a fiber can be easily switched between instruments so that each one of them has 100% of the photons available, rather than just a fraction, when simultaneous measurements are not indispensable. From a more general point of view, once synchrotron light is coupled into the fiber, the vast array of techniques and optoelectronic devices, developed by the telecommunication industry becomes available. In this paper we present the results of our experiments at the Advanced Light Source, where we tried to assess the challenges and limitations of the coupling process and determine what level of efficiency one can typically expect to achieve.

  6. Numerical analysis of influence of heat load on temperature of battery surface with cooling by a two-phase closed thermosyphon

    Directory of Open Access Journals (Sweden)

    Krasnoshlykov Alexander

    2017-01-01

    Full Text Available Numerical analysis of thermal conditions of a two-phase closed thermosyphon using the software package ANSYS FLUENT has been carried out. Time dependence of temperature of heat source surface, which characterize the efficiency of thermosyphon at critical temperatures of batteries have been obtained.

  7. Synchrotron infrared spectromicroscopy as a novel bioanalytical microprobe for individual living cells: Cytotoxicity considerations

    Energy Technology Data Exchange (ETDEWEB)

    Holman, Hoi-Ying N.; Bjornstad, Kathleen A.; McNamara, Morgan P.; Martin, Michael C.; McKinney, Wayne R.; Blakely, Eleanor A.

    2001-12-12

    Synchrotron radiation-based Fourier transform infrared (SR-FTIR) spectromicroscopy is a newly emerging analytical tool capable of monitoring the biochemistry within an individual living mammalian cell in real time. This unique technique provides infrared (IR)spectra, hence chemical information, with high signal-to-noise at spatial resolutions as fine as 3 to 10 microns. Mid-IR photons are too low in energy (0.05-0.5 eV) to either break bonds or to cause ionization, and the synchrotron IR beam has been shown to produce minimal sample heating. However, an important question remains, ''Does the intense synchrotron beam induce any cytotoxic effects in living cells?'' In this work, we present the results from a series of standard biological assays to evaluate any short-and/or long-term effects on cells exposed to the synchrotron radiation-based infrared (SR-IR) beam. Cell viability was tested using alcian blue dye-exclusion and colony formation assays. Cell-cycle progression was tested with bromodeoxyuridine (BrdU) uptake during DNA synthesis. Cell metabolism was tested using an 3-[4,5-Dimethylthiazol-2-yl]-2,5-diphenyltetrazolium bromide assay. All control, 5-, 10-, and 20-minute SR-IR exposure tests (267 total and over 1000 controls) show no evidence of cytotoxic effects. Concurrent infrared spectra obtained with each experiment confirm no detectable chemistry changes between control and exposed cells.

  8. Effect of Pressure Load on Stress Characteristics of the Pre-stressed Heat Exchanger%压力载荷作用对预应力换热器应力特性的影响

    Institute of Scientific and Technical Information of China (English)

    刘义民; 郭崇志

    2016-01-01

    The finite element simulation analysis method was used to numerically calculate the stress of fixed tube heat exchanger. Considering the effect of temperature on the elastic modulus and the pressure load, the stress properties of pre-stressed heat exchanger were researched. Under normal operating conditions, influence of the pressures of tube and shell on the stress of the tube sheet was discussed. Based on a large amount of simulation data, the stress distribution rule for the pressure load on the tube sheet was summarized. Compared with the computational formula of ASME VIII–2, it’s pointed out that the influence of pressure load on the stress of the tube sheet is consistent with the theoretical analysis.%采用有限元数值模拟分析法对固定管板式换热器应力数值计算,考虑温度对材料参数的影响以及压力载荷的作用,探讨预应力换热器的应力特性。在正常操作工况下,讨论管程压力载荷、壳程压力载荷对管板应力的影响,并依据大量的模拟仿真数据总结得到压力载荷对管板的应力变化规律。对比美国 ASME 规范Ⅷ-2中的管板应力计算公式发现,压力载荷对管板应力的影响结果与管板应力计算公式中压力载荷的影响一致。

  9. Target particle and heat loads in low-triangularity L-mode plasmas in JET with carbon and beryllium/tungsten walls

    Energy Technology Data Exchange (ETDEWEB)

    Groth, M., E-mail: mathias.groth@aalto.fi [Aalto University, Association EURATOM-Tekes, Espoo (Finland); Brezinsek, S. [Institute for Energy and Climate Research, Association EURATOM-FZJ Jülich (Germany); Belo, P. [Institute of Plasmas and Nuclear Fusion, Association EURATOM-IST, Lisbon (Portugal); Corrigan, G. [Culham Centre of Fusion Energy, EURATOM-Association, Culham Science Centre, Abingdon (United Kingdom); Harting, D.; Wiesen, S. [Institute for Energy and Climate Research, Association EURATOM-FZJ Jülich (Germany); Beurskens, M.N.A.; Brix, M. [Culham Centre of Fusion Energy, EURATOM-Association, Culham Science Centre, Abingdon (United Kingdom); Clever, M.; Coenen, J.W. [Institute for Energy and Climate Research, Association EURATOM-FZJ Jülich (Germany); Eich, T. [Max-Planck Institute for Plasma Physics, EURATOM-Association, Garching (Germany); Flanagan, J.; Giroud, C. [Culham Centre of Fusion Energy, EURATOM-Association, Culham Science Centre, Abingdon (United Kingdom); Huber, A. [Institute for Energy and Climate Research, Association EURATOM-FZJ Jülich (Germany); Jachmich, S. [Association “EURATOM Belgium State”, Laboratory for Plasma Physics, Brussels (Belgium); Kruezi, U.; Lehnen, M. [Institute for Energy and Climate Research, Association EURATOM-FZJ Jülich (Germany); Lowry, C. [EFDA Close Support Unit, Culham Science Centre, Abingdon (United Kingdom); Maggi, C.F. [Max-Planck Institute for Plasma Physics, EURATOM-Association, Garching (Germany); Marsen, S. [Max-Planck-Institut for Plasma Physics, EURATOM-Association, Greifswald (Germany); and others

    2013-07-15

    Divertor radiation profiles, and power and particle fluxes to the target have been measured in attached JET L-mode plasmas with carbon and beryllium/tungsten wall materials. In the beryllium/tungsten configuration, factors of 2–3 higher power loads and peak temperatures at the low field side target were observed in high-recycling scrape-off layer conditions, whilst in close-to-sheath-limited conditions almost identical plasmas were obtained. The 30% reduction in total radiation with the beryllium/tungsten wall is consistent with a reduction of carbon as the dominant impurity radiator; however similar ion current to the plates, emission from recycling neutrals and neutral pressures in the pumping plenum were measured. Simulations with the EDGDE2/EIRENE code of these plasmas indicate a reduction of the total divertor radiation when carbon is omitted, but significantly higher power loads in high-recycling and detached conditions are predicted than measured.

  10. Heat exchanger device and method for heat removal or transfer

    Science.gov (United States)

    Koplow, Jeffrey P [San Ramon, CA

    2012-07-24

    Systems and methods for a forced-convection heat exchanger are provided. In one embodiment, heat is transferred to or from a thermal load in thermal contact with a heat conducting structure, across a narrow air gap, to a rotating heat transfer structure immersed in a surrounding medium such as air.

  11. Heat exchanger device and method for heat removal or transfer

    Science.gov (United States)

    Koplow, Jeffrey P

    2013-12-10

    Systems and methods for a forced-convection heat exchanger are provided. In one embodiment, heat is transferred to or from a thermal load in thermal contact with a heat conducting structure, across a narrow air gap, to a rotating heat transfer structure immersed in a surrounding medium such as air.

  12. Modelling heating effects in cryocooled protein crystals

    CERN Document Server

    Nicholson, J; Fayz, K; Fell, B; Garman, E

    2001-01-01

    With the application of intense X-ray beams from third generation synchrotron sources, damage to cryocooled macromolecular crystals is being observed more commonly . In order to fully utilize synchrotron facilities now available for studying biological crystals, it is essential to understand the processes involved in radiation damage and beam heating so that, if possible, action can be taken to slow the rate of damage. Finite Element Analysis (FEA) has been applied to model the heating effects of X-rays on cryocooled protein crystals, and to compare the relative cooling efficiencies of nitrogen and helium.

  13. Utilization of heat pipes for transfer heat from the flue gas into the heat transfer medium

    Directory of Open Access Journals (Sweden)

    Lenhard Richard

    2014-03-01

    Full Text Available The contribution is listed possible application of heat pipes in systems for obtaining heat from flue gas of small heat sources. It is also stated in the contribution design an experimental device on which to study the impact of fill (the quantity, type of load at various temperature parameters (temperature heating and cooling thermal power transferred to the heat pipe. Is listed measurement methodology using heat pipes designed experimental facility, measurement results and analysis of the results obtained.

  14. Radiation protection at synchrotron radiation facilities.

    Science.gov (United States)

    Liu, J C; Vylet, V

    2001-01-01

    A synchrotron radiation (SR) facility typically consists of an injector, a storage ring, and SR beamlines. The latter two features are unique to SR facilities, when compared to other types of accelerator facilities. The SR facilities have the characteristics of low injection beam power, but high stored beam power. The storage ring is generally above ground with people occupying the experimental floor around a normally thin concrete ring wall. This paper addresses the radiation issues, in particular the shielding design, associated with the storage ring and SR beamlines. Normal and abnormal beam losses for injection and stored beams, as well as typical storage ring operation, are described. Ring shielding design for photons and neutrons from beam losses in the ring is discussed. Radiation safety issues and shielding design for SR beamlines, considering gas bremsstrahlung and synchrotron radiation, are reviewed. Radiation source terms and the methodologies for shielding calculations are presented.

  15. Synchrotron masers and fast radio bursts

    CERN Document Server

    Ghisellini, Gabriele

    2016-01-01

    Fast Radio Bursts (FRBs), with a typical duration of 1 ms and 1 Jy flux density at GHz frequencies, have brightness temperatures exceeding 1e33 K, requiring a coherent emission process. This can be achieved by bunching particles in volumes smaller than the typical wavelength, but this may be challenging. Alternatively, we can have maser emission. Under certain conditions, the synchrotron stimulated emission process can be more important than true absorption, and a synchrotron maser can be created. This occurs when the emitting electrons have a very narrow distribution of pitch angles and energies. This process overcomes the difficulties of having extremely dense bunches of particles and relaxes the light crossing time limits, since there is no simple relation between the actual size of the source and the observed variability timescale.

  16. Synchrotron Applications of High Magnetic Fields

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2006-07-01

    This workshop aims at discussing the scientific potential of X-ray diffraction and spectroscopy in magnetic fields above 30 T. Pulsed magnetic fields in the range of 30 to 40 T have recently become available at Spring-8 and the ESRF (European synchrotron radiation facility). This document gathers the transparencies of the 6 following presentations: 1) pulsed magnetic fields at ESRF: first results; 2) X-ray spectroscopy and diffraction experiments by using mini-coils: applications to valence state transition and frustrated magnet; 3) R{sub 5}(Si{sub x}Ge{sub 1-x}){sub 4}: an ideal system to be studied in X-ray under high magnetic field?; 4) high field studies at the Advanced Photon Source: present status and future plans; 5) synchrotron X-ray diffraction studies under extreme conditions; and 6) projects for pulsed and steady high magnetic fields at the ESRF.

  17. Synchrotron Mossbauer spectroscopy of powder samples

    Science.gov (United States)

    Alp, E. E.; Sturhahn, W.; Toellner, T.

    1995-05-01

    Synchrotron Mossbauer spectroscopy, SMS, is an emerging technique that allows fast and accurate determination of hyperfine field parameters similar to conventional Mossbauer spectroscopy with radioactive sources. This new technique, however, is qualitatively different from Mossbauer spectroscopy in terms of equipment, methodology, and analysis to warrant a new name. In this paper, we report on isomer shift and quadrupole splitting measurements of Mohr's salt, Fe(NH4)2 (SO4)2 · 6H2O for demonstration purposes. Theoretical calculations were performed and compared to experiments both in energy and time domain to demonstrate the influence of thickness distribution and preferential alignment of powder samples. Such measurements may prove to be useful when the data collection times are reduced to few seconds in the third generation, undulator based synchrotron radiation sources.

  18. Synchrotron masers and fast radio bursts

    Science.gov (United States)

    Ghisellini, G.

    2017-02-01

    Fast radio bursts, with a typical duration of 1 ms and 1 Jy flux density at gigahertz frequencies, have brightness temperatures exceeding 1033 K, requiring a coherent emission process. This can be achieved by bunching particles in volumes smaller than the typical wavelength, but this may be challenging. Maser emission is a possibility. Under certain conditions, the synchrotron-stimulated emission process can be more important than true absorption, and a synchrotron maser can be created. This occurs when the emitting electrons have a very narrow distribution of pitch angles and energies. This process overcomes the difficulties of having extremely dense bunches of particles and relaxes the light-crossing time limits, since there is no simple relation between the actual size of the source and the observed variability time-scale.

  19. Resonant diffraction of synchrotron radiation: New possibilities

    Science.gov (United States)

    Ovchinnikova, E. N.; Mukhamedzhanov, E. Kh.

    2016-09-01

    Resonant diffraction of synchrotron radiation (SR) is a modern method of studying the structure and properties of condensed matter that can be implemented on third-generation synchrotrons. This method allows one to investigate local properties of media (including magnetic and electronic ones) and observe thermal vibrations, defects, and orbital and charge orderings. A brief review of the advance provided by SR resonant diffraction is presented, and the capabilities of this method for analyzing phase transitions are considered in more detail by the example of potassium dihydrogen phosphate and rubidium dihydrogen phosphate crystals. It is shown that the investigation of the temperature dependence of forbidden reflections not only makes it possible to observe the transition from para- to ferroelectric phase, but also gives information about the proton distribution at hydrogen bonds.

  20. Load Measurements

    DEFF Research Database (Denmark)

    Kock, Carsten Weber; Vesth, Allan

    The report describes Load measurements carried out on a given wind turbine. The aim of the measurement program regarding the loads on the turbine is to verify the basic characteristics of the wind turbine and loads on the blades, the rotor and the tower, using [Ref 1], [Ref2] and [Ref 3]. Regarding...... the fatigue loads, the rotor, blades and tower moments are presented. The fatigue loads are evaluated using rainflow counting described in detail in Ref. [1]. The 1Hz equivalent load ranges are calculated at different wind speeds. All information regarding the instrumentation is collected in [ref 4] and [ref...

  1. Note: Dynamic strain field mapping with synchrotron X-ray digital image correlation

    Energy Technology Data Exchange (ETDEWEB)

    Lu, L. [CAS Key Laboratory of Mechanical Behavior and Design of Materials, Department of Modern Mechanics, University of Science and Technology of China, Hefei, Anhui 230027 (China); The Peac Institute of Multiscale Sciences, Chengdu, Sichuan 610207 (China); Fan, D.; Luo, S. N., E-mail: sluo@pims.ac.cn [The Peac Institute of Multiscale Sciences, Chengdu, Sichuan 610207 (China); Bie, B. X. [The Peac Institute of Multiscale Sciences, Chengdu, Sichuan 610207 (China); School of Science, Wuhan University of Technology, Wuhan, Hubei 430070 (China); Ran, X. X.; Qi, M. L., E-mail: qiml@whut.edu.cn [School of Science, Wuhan University of Technology, Wuhan, Hubei 430070 (China); Parab, N.; Sun, J. Z.; Liao, H. J.; Hudspeth, M. C.; Claus, B. [School of Aeronautics and Astronautics, Purdue University, West Lafayette, Indiana 47907 (United States); Fezzaa, K.; Sun, T. [Advanced Photon Source, Argonne National Laboratory, Argonne, Illinois 60439 (United States); Chen, W. [School of Aeronautics and Astronautics, Purdue University, West Lafayette, Indiana 47907 (United States); School of Material Science Engineering, Purdue University, West Lafayette, Indiana 47907 (United States); Gong, X. L., E-mail: gongxl@ustc.edu.cn [CAS Key Laboratory of Mechanical Behavior and Design of Materials, Department of Modern Mechanics, University of Science and Technology of China, Hefei, Anhui 230027 (China)

    2014-07-15

    We present a dynamic strain field mapping method based on synchrotron X-ray digital image correlation (XDIC). Synchrotron X-ray sources are advantageous for imaging with exceptional spatial and temporal resolutions, and X-ray speckles can be produced either from surface roughness or internal inhomogeneities. Combining speckled X-ray imaging with DIC allows one to map strain fields with high resolutions. Based on experiments on void growth in Al and deformation of a granular material during Kolsky bar/gas gun loading at the Advanced Photon Source beamline 32ID, we demonstrate the feasibility of dynamic XDIC. XDIC is particularly useful for dynamic, in-volume, measurements on opaque materials under high strain-rate, large, deformation.

  2. Plasma diagnostics using synchrotron radiation in tokamaks

    Energy Technology Data Exchange (ETDEWEB)

    Fidone, I.; Giruzzi, G.; Granata, G.

    1995-09-01

    This report deal with the use of synchrotron radiation in tokamaks. The main advantage of this new method is that it enables to overcome several deficiencies, caused by cut-off, refraction, and harmonic overlap. It also makes it possible to enhance the informative contents of the familiar low harmonic scheme. The basic theory of the method is presented and illustrated by numerical applications, for plasma parameters of relevance in present and next step tokamaks. (TEC). 10 refs., 13 figs.

  3. The Synchrotron Radiation for Steel Research

    OpenAIRE

    Piyada Suwanpinij

    2016-01-01

    The synchrotron X-ray radiation is a great tool in materials characterization with several advantageous features. The high intensity allows clear interaction signals and high energy of X-ray yields higher sampling volume. The samples do not need extra preparation and the microstructure is therefore not affected. With the tunability of the X-ray energy, a large range of elements and features in the samples can be investigated by different techniques, which is a significant difference between a...

  4. Hammurabi: Simulating polarized Galactic synchrotron emission

    Science.gov (United States)

    Jaffe, Tess; Waelkens, Andre; Reinecke, M.; Kitaura, F. S.; Enßlin, T. A.

    2012-01-01

    The Hammurabi code is a publicly available C++ code for generating mock polarized observations of Galactic synchrotron emission with telescopes such as LOFAR, SKA, Planck, and WMAP, based on model inputs for the Galactic magnetic field (GMF), the cosmic-ray density distribution, and the thermal electron density. The Hammurabi code allows one to perform simulations of several different data sets simultaneously, providing a more reliable constraint of the magnetized ISM.

  5. Coherent synchrotron radiation: Theory and experiments

    Energy Technology Data Exchange (ETDEWEB)

    Courtland L. Bohn

    2002-07-19

    Our understanding of the generation of coherent synchrotron radiation in magnetic bending systems and its impact on beam dynamics has grown considerably over the past few years. The search for understanding has brought a number of surprises, all related to the complexity of the fully self-consistent problem. Herein I survey the associated phenomenology, theory, and experiments while emphasizing important subtleties that have recently been uncovered. I conclude by speculating on courses of future investigations that may prove fruitful.

  6. Multipurpose furnace for in situ studies of polycrystalline materials using synchrotron radiation.

    Science.gov (United States)

    Sharma, Hemant; Wattjes, Alix C; Amirthalingam, Murugaiyan; Zuidwijk, Thim; Geerlofs, Nico; Offerman, S Erik

    2009-12-01

    We report a multipurpose furnace designed for studies using synchrotron radiation on polycrystalline materials, namely, metals, ceramics, and (semi)crystalline polymers. The furnace has been designed to carry out three-dimensional (3D) x-ray diffraction measurements but can also be used for other types of synchrotron radiation research. The furnace has a very low thermal gradient across the specimen (welding a thermocouple to the specimen. The furnace can be rotated over an angle of 90 degrees in order to determine the crystallographic orientation of each individual grain. It is possible to follow growth kinetics of all grains in the illuminated volume of the specimen. The specimen environment can be controlled varying from vacuum (up to 10(-5) mbar) to gas or air filled. The maximum temperature of operation is 1500 degrees C, with the possibility of achieving high heating (up to 20 degrees C/s) and cooling rates (up to 30 degrees C/s without quenching gas). 3D maps of the microstructure of the specimen can be generated at elevated temperatures by bringing the high-resolution detector close to the specimen. We show an example of a simulation of the heat affected zone during the thermal cycle of a weld in a transformation-induced plasticity steel carried out using the furnace. The unique characteristics of the furnace open possibility of new fields in materials research using synchrotron radiation.

  7. DEVELOPMENT OF THE COMPLEX-ALLOYED STEEL OF INCREASED HARDENABILITY, VISCOSITY AND HEAT-RESISTANCE FOR CUTTING PARTS OF HIGH-SPEED INSTRUMENT, OPERATING IN CONDITIONS OF HEATING UP AND DYNAMIC LOADS

    Directory of Open Access Journals (Sweden)

    V. N. Fedulov

    2006-01-01

    Full Text Available The theoretical aspects of development of the complex-alloyed steel compounds for cutting parts of high-speed instrument, particularly influence of alloying elements on its structure and characteristics are considered. It is shown that combined alloying of steel by carbon, chrome, silicon, manganese, vanadium and molybdenum in a certain proportion allows to reach the intended aim, achieving at the same time increase of solidity, impact elasticity and heat stability.

  8. MICROANALYSIS OF MATERIALS USING SYNCHROTRON RADIATION.

    Energy Technology Data Exchange (ETDEWEB)

    JONES,K.W.; FENG,H.

    2000-12-01

    High intensity synchrotron radiation produces photons with wavelengths that extend from the infrared to hard x rays with energies of hundreds of keV with uniquely high photon intensities that can be used to determine the composition and properties of materials using a variety of techniques. Most of these techniques represent extensions of earlier work performed with ordinary tube-type x-ray sources. The properties of the synchrotron source such as the continuous range of energy, high degree of photon polarization, pulsed beams, and photon flux many orders of magnitude higher than from x-ray tubes have made possible major advances in the possible chemical applications. We describe here ways that materials analyses can be made using the high intensity beams for measurements with small beam sizes and/or high detection sensitivity. The relevant characteristics of synchrotron x-ray sources are briefly summarized to give an idea of the x-ray parameters to be exploited. The experimental techniques considered include x-ray fluorescence, absorption, and diffraction. Examples of typical experimental apparatus used in these experiments are considered together with descriptions of actual applications.

  9. 50 Years of synchrotrons Adams' Memorial lecture

    CERN Document Server

    Lawson, J D; CERN. Geneva

    1996-01-01

    Fifty years ago Frank Goward of the Atomic Energy Research Establishment Group at Malvern converted a small American betatron to make the worldÕs first synchrotron. At the same time Marcus Oliphant was planning to build at Birmingham a large proton machine with a ring magnet and variable magnetic field. Ideas for this had come to him during night-shifts tending the electromagnetic separators at Oak Ridge during the war. Some seven years later, in 1953, a group gathered together in Geneva to build the PS. A major contributor to the design work which had made this possible was John Adams. An account of some of the achievements in these eventful years will be presented. CERN has built nine synchrotrons/colliders and two temporary test rings. Eight machines are still running. The review will start with the PS, the first proton synchrotron based on the alternating gradient principle invented in 1952 at BNL. The design work of the PS team, under the enlightened leadership of J.B. Adams, and the construction of the...

  10. Theory of the Alternating-Gradient Synchrotron

    Science.gov (United States)

    Courant, E. D.; Snyder, H. S.

    2000-04-01

    The equations of motion of the particles in a synchrotron in which the field gradient indexn=-(r/B) ∂B/∂rvaries along the equilibrium orbit are examined on the basis of the linear approximation. It is shown that if n alternates rapidly between large positive and large negative values, the stability of both radial and vertical oscillations can be greatly increased compared to conventional accelerators in which n is azimuthally constant and must lie between 0 and 1. Thus aperture requirements are reduced. For practical designs, the improvement is limited by the effects of constructional errors; these lead to resonance excitation of oscillations and consequent instability if 2νx or 2νz or νx+νz is integral, where νx and νz are the frequencies of horizontal and vertical betatron oscillations, measured in units of the frequency of revolution. The mechanism of phase stability is essentially the same as in a conventional synchrotron, but the radial amplitude of synchrotron oscillations is reduced substantially. Furthermore, at a "transition energy" E1≈νxMc2 the stable and unstable equilibrium phases exchange roles, necessitating a jump in the phase of the radiofrequency accelerating voltage. Calculations indicate that the manner in which this jump is performed is not very critical.

  11. Tabletop synchrotron and its unique features

    CERN Document Server

    Yamada, H

    2002-01-01

    Two synchrotrons, AURORA and MIRRORCLE, were built in Ritsumeikan University. MIRRORCLE-20 is the smallest normal conduction synchrotron (15 cm orbit radius and 1.2 m outer diameter) in the world. It uses 2/3 resonance method for electron beam incidence but is not optimized for X-ray generation. MIRRORCLE-6 shall be optimized for X-ray generation. X-ray generated by MIRRORCLE shows very flat white light, rich in hard X-ray, pulse with width changeable from a few mu s to a few ms , wide radiation angle of 25 mrad at MIRRORCLE-20 and 80 mrad at MIRRORCLE-8 and high coherence. The feature such as pulsed light and high coherence is expected to new application which photon radiation cannot practice. Imaging experiments by MIRRORCLE were carried out by Cu plate, Al plate, Teflon and acryl plate. We took a photograph of insect, electric lamp, connector, and cyclotron. New X-ray generation mechanism, X-ray strength, development of tabletop synchrotron and features of X-ray beam are explained. (S.Y.)

  12. 利用热网储能提高供热机组调频调峰能力的控制方法%A Control Method of Heat Supply Units for Improving Frequency Control and Peak Load Regulation Ability With Thermal Storage in Heat Supply Net

    Institute of Scientific and Technical Information of China (English)

    邓拓宇; 田亮; 刘吉臻

    2015-01-01

    城市供热管网包含大量管道和换热设备,具有大容量的储能。为了提高供热机组调峰调频能力,利用热网储能,提出了一种带供热前馈的供热机组协调控制方案。经特性分析和现场数据验证,改变供热快关阀开度,能够利用热网蓄热快速改变机组发电负荷。针对热网蓄热调节负荷迅速这一特点,采用速率限制非线性分解方法将机组负荷指令信号中的快变部分分解出来作为供热前馈加在快关阀开度指令上。在原有炉跟机协调控制系统中引入前馈信号不影响原有系统的稳定性,利于工程应用。仿真结果表明,该方案能够利用热网蓄热有效减少供热机组机前压力波动,从而使机组在运行允许范围内接受3%Pe/min的变负荷速率,提高了机组参与调峰调频的能力。%Heat supply net contains a large number of tubes and heat exchangers in which contain large capacity energy storage. To enhance the frequency control and peak load regulation in grid, energy storage in heat supply net was utilized and a coordinated control method with heat supply feedforward part was proposed. Characteristic analysis and experimental data showed that unit power generation changes quickly by regulation of heat supply emergency cut-off valves. In the light of rapid regulating characteristic of heat supply net thermal storage, fast varying part of the unit load command was separated by rate limiting nonlinear decomposition method and added to emergency cut-off valve command as a feedforward signal. Including the heat supply feedforward part, a coordinated control method based on the existed boiler- following coordinated control scheme was purposed. The feedforward control won’t change the stability of system and is easy to engineering implementation. Simulation results show that, this control method reduce throttle pressure fluctuation effectively by usage of net thermal storage; so the units can

  13. Detailed Resolution Studies of the Synchrotron Radiation Profile Monitor for the HERA Electron Beam

    CERN Document Server

    Kube, G; Wittenburg, K

    2005-01-01

    The precise determination of the beam emittance is essential for the understanding of the luminosity in colliding beam experiments as the ones at the e-p storage ring HERA at DESY. For the measurement of the electron beam emittance a monitor is used which is based on the direct imaging of visible synchrotron radiation from a bending magnet. In order to reduce the thermal heating of the light extracting beryllium mirror it is moved away from the beam axis in vertical direction. While the resolution of profile measurements by synchrotron radiation is already strictly limited by fundamental effects, the observation in off-axis geometry modifies the intensity distribution additionally leading to an increased contribution of the diffraction limited resolution. In order to describe the resolution broadening effects detailed calculations have been performed with the computer code SRW. Taking into account the calculated corrections the deduced beam emittances are in good agreement with independent measurements from a...

  14. Load Measurements

    DEFF Research Database (Denmark)

    Vesth, Allan; Kock, Carsten Weber

    The report describes Load measurements carried out on a given wind turbine. The aim of the measurement program regarding the loads on the turbine is to verify the basic characteristics of the wind turbine and loads on the blades, the rotor and the tower, using [Ref 1], [Ref2] and [Ref 3]. Regardi...

  15. Load Measurements

    DEFF Research Database (Denmark)

    Kock, Carsten Weber; Vesth, Allan

    The report describes Load measurements carried out on a given wind turbine. The aim of the measurement program regarding the loads on the turbine is to verify the basic characteristics of the wind turbine and loads on the blades, the rotor and the tower, using [Ref 1], [Ref2] and [Ref 3]. Regarding...

  16. Recent Research and Progress in Food, Feed and Nutrition with Advanced Synchrotron-based SR-IMS and DRIFT Molecular Spectroscopy.

    Science.gov (United States)

    Liu, Na; Yu, Peiqiang

    2016-01-01

    Ultraspatially resolved synchrotron radiation based infrared microspectroscopy is able to detect the structure features of a food or feed tissue at cellular and molecular levels. However, to date, this advanced synchrotron-based technique is almost unknown to food and feed scientists. The objective of this article was to introduce this novel analytical technology, ultra-spatially resolved synchrotron radiation based infrared microspectroscopy (SR-IMS) to food, feed, conventional nutrition, and molecular nutrition scientists. The emphasis of this review focused on the following areas: (1) Principles of molecular spectroscopy for food and feed structure research, such as protein molecular structure, carbohydrate conformation, heating induced protein structure changes, and effect of gene-transformation on food and feed structure; (2) Molecular spectral analysis methodology; (3) Biological applications of synchrotron SR-IMS and DRIFT spectroscopy; and (4) Recent progress in food, feed and nutrition research program. The information described in this article gives better insight in food structure research progress and update.

  17. Comparison of the impact of six heat-load management strategies on thermal responses and milk production of feed-pad and pasture fed dairy cows in a subtropical environment

    Science.gov (United States)

    Davison, T. M.; Jonsson, N. N.; Mayer, D. G.; Gaughan, J. B.; Ehrlich, W. K.; McGowan, M. R.

    2016-12-01

    Exposure to hot environments affects milk yield (MY) and milk composition of pasture and feed-pad fed dairy cows in subtropical regions. This study was undertaken during summer to compare MY and physiology of cows exposed to six heat-load management treatments. Seventy-eight Holstein-Friesian cows were blocked by season of calving, parity, milk yield, BW, and milk protein (%) and milk fat (%) measured in 2 weeks prior to the start of the study. Within blocks, cows were randomly allocated to one of the following treatments: open-sided iron roofed day pen adjacent to dairy (CID) + sprinklers (SP); CID only; non-shaded pen adjacent to dairy + SP (NSD + SP); open-sided shade cloth roofed day pen adjacent to dairy (SCD); NSD + sprinkler (sprinkler on for 45 min at 1100 h if mean respiration rate >80 breaths per minute (NSD + WSP) ); open-sided shade cloth roofed structure over feed bunk in paddock + 1 km walk to and from the dairy (SCP + WLK). Sprinklers for CID + SP and NSD + SP cycled 2 min on, 12 min off when ambient temperature >26°C. The highest milk yields were in the CID + SP and CID treatments (23.9 L cow-1 day-1), intermediate for NSD + SP, SCD and SCP + WLK (22.4 L cow-1 day-1), and lowest for NSD + WSP (21.3 L cow-1 day-1) ( P 80.7. A combination of iron roof shade plus water sprinkling throughout the day provided the most effective control of heat load.

  18. Medical applications of synchrotron radiation at the National Synchrotron Light Source

    Energy Technology Data Exchange (ETDEWEB)

    Thomlinson, W.

    1992-10-01

    The overriding features of the synchrotron beams which make them applicable to medical research are their extremely high intensity and broadband energy spectrum. Several orders of magnitude separate the smooth, continuous spectrum of the synchrotron from the sharply peaked characteristic emission spectrum of a conventional source. Basically, the high intensity and tunability allow monochromatic beams to be generated at virtually any energy. The standard problem of beam hardening in both medical imaging and therapy is eliminated by the monochromatic beams since the energy spectrum does not change with passage through tissue. The tunable spectrum allows enhancement of images and therapeutic dose by selection of the most effective energy for a given procedure.

  19. Medical applications of synchrotron radiation at the National Synchrotron Light Source

    Energy Technology Data Exchange (ETDEWEB)

    Thomlinson, W.

    1992-01-01

    The overriding features of the synchrotron beams which make them applicable to medical research are their extremely high intensity and broadband energy spectrum. Several orders of magnitude separate the smooth, continuous spectrum of the synchrotron from the sharply peaked characteristic emission spectrum of a conventional source. Basically, the high intensity and tunability allow monochromatic beams to be generated at virtually any energy. The standard problem of beam hardening in both medical imaging and therapy is eliminated by the monochromatic beams since the energy spectrum does not change with passage through tissue. The tunable spectrum allows enhancement of images and therapeutic dose by selection of the most effective energy for a given procedure.

  20. New synchrotron radiation facility project. Panel on new synchrotron radiation facility project

    CERN Document Server

    Sato, S; Kimura, Y

    2003-01-01

    The project for constructing a new synchrotron radiation facility dedicated to the science in VUV (or EUV) and Soft X-ray (SX) region has been discussed for these two years at the Panel on New Synchrotron Radiation Facility Project. The Panel together with the Accelerator Design Working Group (WG), Beamline Design WG and Research Program WG suggested to the Ministry of Education, Science, Culture and Sports the construction of a 1.8 GeV electron storage ring suitable for 'Top-Up' operation and beamlines and monochromators designed for undulator radiation. The scientific programs proposed by nationwide scientists are summarized with their requirements of the characteristics of the beam. (author)

  1. PERFORMANCE ANALYSIS OF MULTI-TURN EXTRACTION FROM THE PROTON SYNCHROTRON TO THE SUPER PROTON SYNCHROTRON

    CERN Document Server

    Abernethy, Samuel

    2016-01-01

    Within CERN's accelerator complex, the extraction from the Proton Synchrotron to the Super Proton Synchrotron has been done using the so-called ``Continuous Transfer" (CT) method since the 1970's. A new technique, known as Multi-Turn Extraction (MTE), has now been implemented and is in full operation. This report examines a holistic performance analysis of the novel technique in multiple aspects of the accelerator complex, as well as a direct comparison with its predecessor, CT, from the implementation of MTE in 2010 until the end of 2015.

  2. Optimal design of a beam stop for Indus-2 using finite element heat transfer studies

    Indian Academy of Sciences (India)

    A K Sinha; K J S Sawhney; R V Nandedkar

    2001-12-01

    This paper describes the design of an in-vacuum, water-cooled beam stop (X-ray shutter) for the materials science (X-ray diffraction) beamline proposed to be built on the wavelength shifter in the Indus-2 (2.5 GeV) synchrotron radiation source. The radiation source impinges ∼ 1 kW power on the beam stop and the heat transfer capabilities of the beam stop have been evaluated. Temperature distribution in the beam stop has been obtained under various cooling conditions using the finite element analysis calculations with ANSYS software. Design parameters of the beam stop have been optimised. It is also shown that radiation cooling alone is not sufficient for taking away the heat load. Water-cooling of the beam stop is essential.

  3. Surface modifications of rolled W during exposure to high heat loads with He%轧制钨板在氦源高热流作用下的形貌演化

    Institute of Scientific and Technical Information of China (English)

    李纯; Henri Greuner; 周鑫; 罗广南; 刘伟

    2015-01-01

    Background: Tungsten (W) is a promising candidate for future use in fusion reactors as plasma facing material. During operation it will be exposed to both particle irradiation and high heat flux (HHF) loads. Particle irradiation, especially helium (He), is expected to cause significant surface modifications of W, might leading to performance degradation. The effect of heat loading can accelerate such surface damage. Therefore, the performance of W under the combined action of both heat and particle fluxes has to be investigated in more detail.Purpose:The aim is to investigate the surface modifications of rolled W during exposure to combined heating and He particle flux depending on surface temperature, He flux and fluence.Methods: The He-flux/heating experiments were performed on rolled W samples using the neutral beam HHF test facility GLADIS at IPP Garching, Germany. HHF loads generated with He atoms of 2.4 MW·m−2 and 9.5 MW·m−2 were used. W samples were adiabatically loaded to peak surface temperatures of ~1000 K, ~2000 K and ~3000 K, close to melting. He fluences increased from about 1×1021m−2 to 6×1022 m−2.Results: During He-loading at a low surface temperature (~1000 K), with increasing fluence, defects appeared in grains first, and then blistering was observed on the sample surface, with many ruptured blisters to form lids and grooves. The largest blisters formed on grains with near surface normal. As fluence was increased continuously, small holes were formed on the surface, and the grooves still existed. However, at intermediate surface temperature (~2000 K), with increasing fluence, the damage morphology changed from a porous structure with blisters,via a porous structure with grooves, to a small coral-like structure. At high surface temperature (~3000 K), an evolution from a porous structure to a coral-like structure with increasing fluence was observed, and the coral-like structure changed little as the increasing of fluence continuously. It

  4. Heat pumps in agricultural uses. Factsheet

    Energy Technology Data Exchange (ETDEWEB)

    MacDonald, R.D.

    1986-04-01

    This paper provides an elementary introduction to heat pumps and their potential for use in Ontario agricultural applications, taking into account local climatic conditions which mean high heating loads and small cooling loads. A heat pump's ability to remove heat from a variety of sources and boost this heat to a useable temperature enables such farm uses as recovery of heat from exhaust air in livestock barns, greenhouse heating using ground water, and heat extraction from manure. Basic types of heat pumps are evaluated and compared, and their costs are estimated.

  5. Experimental and Numerical Study of Buckling of Vacuum Chambers for Fast-Cycling Synchrotrons

    DEFF Research Database (Denmark)

    Bräuner, Lars Erik

    The optimal functioning of the long span thin walled elliptical cross section shells used as vacuum chambers for fast-cycling synchrotrons is provided by their buckling capacity. Also it is often necessary to design inter-stiffener panels of elliptical shells used as vacuum chambers to resist any...... tendency towards pressure induced buckling due to some combination of excessive out-gassing, fragility, radiation damage, magnetic field distortion,. The analysis for design is complicated because elliptical shell chambers display a complex form of nonlinear snap buckling behavior under the external...... pressure. Buckling analysis for shells is further complicated by the observation that geometric imperfections have an important influence on the buckling mode as well as on the buckling load-carrying capacity. Buckling loads are, in general, considerably lower than the lowest critical loads predicted from...

  6. Combined resistive and laser heating technique for in situ radial X-ray diffraction in the diamond anvil cell at high pressure and temperature.

    Science.gov (United States)

    Miyagi, Lowell; Kanitpanyacharoen, Waruntorn; Raju, Selva Vennila; Kaercher, Pamela; Knight, Jason; MacDowell, Alastair; Wenk, Hans-Rudolf; Williams, Quentin; Alarcon, Eloisa Zepeda

    2013-02-01

    To extend the range of high-temperature, high-pressure studies within the diamond anvil cell, a Liermann-type diamond anvil cell with radial diffraction geometry (rDAC) was redesigned and developed for synchrotron X-ray diffraction experiments at beamline 12.2.2 of the Advanced Light Source. The rDAC, equipped with graphite heating arrays, allows simultaneous resistive and laser heating while the material is subjected to high pressure. The goals are both to extend the temperature range of external (resistive) heating and to produce environments with lower temperature gradients in a simultaneously resistive- and laser-heated rDAC. Three different geomaterials were used as pilot samples to calibrate and optimize conditions for combined resistive and laser heating. For example, in Run#1, FeO was loaded in a boron-mica gasket and compressed to 11 GPa then gradually resistively heated to 1007 K (1073 K at the diamond side). The laser heating was further applied to FeO to raise temperature to 2273 K. In Run#2, Fe-Ni alloy was compressed to 18 GPa and resistively heated to 1785 K (1973 K at the diamond side). The combined resistive and laser heating was successfully performed again on (Mg0.9Fe0.1)O in Run#3. In this instance, the sample was loaded in a boron-kapton gasket, compressed to 29 GPa, resistive-heated up to 1007 K (1073 K at the diamond side), and further simultaneously laser-heated to achieve a temperature in excess of 2273 K at the sample position. Diffraction patterns obtained from the experiments were deconvoluted using the Rietveld method and quantified for lattice preferred orientation of each material under extreme conditions and during phase transformation.

  7. Combined resistive and laser heating technique for in situ radial X-ray diffraction in the diamond anvil cell at high pressure and temperature

    Energy Technology Data Exchange (ETDEWEB)

    Miyagi, Lowell [Department of Geology and Geophysics, University of Utah, Salt Lake City, Utah 84112 (United States); Department of Earth Sciences, Montana State University, Bozeman, Montana 59717 (United States); Kanitpanyacharoen, Waruntorn; Kaercher, Pamela; Wenk, Hans-Rudolf; Alarcon, Eloisa Zepeda [Department of Earth and Planetary Science, University of California, Berkeley, California 94720 (United States); Raju, Selva Vennila [Advanced Light Source, Lawrence Berkeley Laboratory, Berkeley, California 94720 (United States); HiPSEC, Department of Physics, University of Nevada, Las Vegas, Nevada 89154 (United States); Knight, Jason; MacDowell, Alastair [Advanced Light Source, Lawrence Berkeley Laboratory, Berkeley, California 94720 (United States); Williams, Quentin [Department of Earth and Planetary Science, University of California, Santa Cruz, California 95064 (United States)

    2013-02-15

    To extend the range of high-temperature, high-pressure studies within the diamond anvil cell, a Liermann-type diamond anvil cell with radial diffraction geometry (rDAC) was redesigned and developed for synchrotron X-ray diffraction experiments at beamline 12.2.2 of the Advanced Light Source. The rDAC, equipped with graphite heating arrays, allows simultaneous resistive and laser heating while the material is subjected to high pressure. The goals are both to extend the temperature range of external (resistive) heating and to produce environments with lower temperature gradients in a simultaneously resistive- and laser-heated rDAC. Three different geomaterials were used as pilot samples to calibrate and optimize conditions for combined resistive and laser heating. For example, in Run1, FeO was loaded in a boron-mica gasket and compressed to 11 GPa then gradually resistively heated to 1007 K (1073 K at the diamond side). The laser heating was further applied to FeO to raise temperature to 2273 K. In Run2, Fe-Ni alloy was compressed to 18 GPa and resistively heated to 1785 K (1973 K at the diamond side). The combined resistive and laser heating was successfully performed again on (Mg{sub 0.9}Fe{sub 0.1})O in Run3. In this instance, the sample was loaded in a boron-kapton gasket, compressed to 29 GPa, resistive-heated up to 1007 K (1073 K at the diamond side), and further simultaneously laser-heated to achieve a temperature in excess of 2273 K at the sample position. Diffraction patterns obtained from the experiments were deconvoluted using the Rietveld method and quantified for lattice preferred orientation of each material under extreme conditions and during phase transformation.

  8. Injection System design for a hadron therapy Synchrotron

    Institute of Scientific and Technical Information of China (English)

    ZHANG Jin-Quan; SONG Ming-Tao; WEI Bao-Wen

    2008-01-01

    A synchrotron is designed for tumour therapy with C6+ ions or proton.Its injector is a cyclotron, which delivers C5+or H+2 ions to the synchrotron.After comparing the methods of the single-turn injection, the multi-turn injection and the stripping injection,this paper chooses the stripping injection method.In addition,the concept design of the injection system is presented,in which the synchrotron lattice is optimized.

  9. Improvements of the TROLL-2 synchrotron and new developments

    Science.gov (United States)

    Anevsky, S. I.; Vernyi, A. E.; Panasyuk, V. S.; Khromchenko, V. B.

    1991-10-01

    Information on radical improvements of the TROLL-2 synchrotron, a specialized pulsed synchrotron radiation source, is presented in this article. Two new variants for particle injection from a solid electromagnet to a ring one, as a specialized continuous synchrotron radiation source are considered. Particle pre-acceleration from thermal velocities to injection energy herewith may take place both in the synchronous and in the isochrone regime.

  10. 适量木炭粉改善环氧树脂复合材料热/力学性能%Suitable charcoal loadings improving heat-resistance and mechanical properties of epoxy resins composites

    Institute of Scientific and Technical Information of China (English)

    宋剑斌; 黄彪; 袁全平; 刘学莘; 杨文斌

    2015-01-01

    investigated using scanning electron microscope (SEM), material testing machines, dynamical thermal mechanical analyzer (DMA) and Vicat softening temperature (VST) measuring instrument. The epoxy, diluents and curing agent at weight ratio of 3:2:5 were used to yield charcoal/epoxy composites. The weight fraction of charcoal in composite was set to 5%, 10%, 20%, 30% and 40%, and the curing temperature and curing time were 100℃ and 3 h, respectively. The results showed that the charcoal in composites, acting as physical cross-link, could improve the mechanical properties of epoxy resins. The flexural strength of composites increased from 10.1 to 38.2 MPa as charcoal loading increased from 0 to 10%, but it started to reduce when charcoal loading exceeded 10%. Like flexural strength, the impact strength of composites also increased from 8.7 to 20.5 kJ/m2 within 10% charcoal loading. However, the flexural modulus of composites increased with charcoal loading increasing till 30%. At high charcoal content, due to the poor wetting properties of charcoal, the mechanical properties of composites began to decrease. The DMA results confirmed that the glass transition temperature of epoxy resins was elevated from 37.5℃ to 60.5℃ as charcoal loading increased from 0 to 10%, indicating strong interaction between epoxy and charcoal. When charcoal loading exceeded 10%, the glass transition temperature started to decline, but it was still higher than that of net epoxy resins. The addition of charcoal improved the heat resistance of epoxy composites, and the VST of charcoal/epoxy composites increased linearly with the increasing of charcoal loading. The 10% charcoal made the VST of epoxy resins increase from 81.2℃ to 126.6℃. Further elevating the charcoal loading caused the VST of composites to exceed 200℃. The results indicate that the charcoal/epoxy composites have better mechanical properties and heat resistance with the charcoal loading of 10%.

  11. Thermal load capacity analysis on small lakes utilized as heat source-sink of surface water heat pump systems%小型湖泊应用于地表水源热泵时的热承载能力分析

    Institute of Scientific and Technical Information of China (English)

    陈晓; 林汉柱; 林宣军; 李明

    2011-01-01

    Two thermal load capacity calculation methods including the water surface temperature method and the uniform mixing method for small lakes utilized as heat source-sink of surface water heat pump systems were introduced. The calculation results of the Hangzhou City indicate that the water surface temperature method is more convincing because it objectively reflects the process of discharge-mixing and water temperature recovering. Thermal load capacity calculations of small lakes in seven representative cities were performed. The results show that the thermal load capacity in summer varies from 23,4W/m2 to 29.5W/m2, and that in winter varies from 31.6W/m2 to 45.7W/m2. The key issue for the design of such surface water heat pump systems is to satisfy the constraint of thermal load capacity in summer.%分析了小型湖泊应用于地表水源热泵时的两种热承载能力计算方法——水面温度法和均匀混合法,并采用其计算了杭州小型湖泊应用于地表水源热泵时的热承载能力。计算结果表明:水面温度法较客观地反映了实际的排水混合及水温恢复过程,可信度更高。用水面温度法对7个代表性城市小型湖泊热承载能力进行分析的结果表明:夏季热承载能力在23-4—29.5W/m2之间,冬季热承载能力在31.6~45.7W/m2之间;设计这类系统的关键在于满足夏季热承载能力的约束。

  12. Laser synchrotron radiation and beam cooling

    Energy Technology Data Exchange (ETDEWEB)

    Esarey, E.; Sprangle, P.; Ting, A. [Naval Research Lab., Washington, DC (United States)] [and others

    1995-12-31

    The interaction of intense {approx_gt} 10{sup 18} W/cm{sup 2}, short pulse ({approx_lt} 1 ps) lasers with electron beams and plasmas can lead to the generation of harmonic radiation by several mechanisms. Laser synchrotron radiation may provide a practical method for generating tunable, near monochromatic, well collimated, short pulse x-rays in compact, relatively inexpensive source. The mechanism for the generation of laser synchrotron radiation is nonlinear Thomson scattering. Short wavelengths can be generated via Thomson scattering by two methods, (i) backscattering from relativistic electron beams, in which the radiation frequency is upshifted by the relativistic factor 4{gamma}{sup 2}, and (ii) harmonic scattering, in which a multitude of harmonics are generated with harmonic numbers extending out to the critical harmonic number nc{approx_equal}a{sub 0}{sup 3} {much_gt} 1, where a{sub 0} {approx_equal}10{sup -9}{lambda}I{sup 1/2}, {lambda} is the laser wavelength in {mu}m and I is the laser intensity in W/cm{sup 2}. Laser synchrotron sources are capable of generating short ({approx_lt} ps) x-ray pulses with high peak flux ({approx_gt} 10{sup 21} photons/s) and brightness ({approx_gt}{sup 19} photons/s-mm{sup 2}-mrad{sup 2} 0.1%BW. As the electron beam radiates via Thomson scattering, it can subsequently be cooled, i.e., the beam emittance and energy spread can be reduced. This cooling can occur on rapid ({approximately} ps) time scales. In addition, electron distributions with sufficiently small axial energy spreads can be used to generate coherent XUV radiation via a laser-pumped FEL mechanism.

  13. Glancing angle synchrotron X-ray diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Cernik, R.J. [Daresbury Lab., Warrington, WA (United States)

    1996-09-01

    This paper describes in basic detail some of the techniques that can be used to study thin films and surfaces. These are all in the X-ray region and cover reflectivity, diffraction form polycrystalline films, textured films and single crystal films. Other effects such as fluorescence and diffuse scattering are mentioned but not discussed in detail. Two examples of the reflectivity from multilayers and the diffraction from iron oxide films are discussed. The advantages of the synchrotron for these studies is stressed and the experimental geometries that can be employed are described i detail. A brief bibliography is provided at the end to accompany this part of the 1996 Frascati school.

  14. Multi turn beam extraction from synchrotron

    Energy Technology Data Exchange (ETDEWEB)

    Tsoupas, Nicholaos

    2017-01-24

    This disclosure relates to apparatuses and methods for the extraction of particle beams while maintaining the energy levels and precision of the particles and the particle beam. Apparatuses and methods for extracting a charged particle beam from a central orbit in a synchrotron are provided, in which a particle beam is deflected from the central orbit. Parts of the deflected particle beam passes through a stripping foil placed in at least parts of the deflected path such that the particles that pass through the foil are stripped of at least one electron. The electron stripped particles and the non-stripped particles may be separated magnetically.

  15. Synchrotron radiation facilities in the USA

    Energy Technology Data Exchange (ETDEWEB)

    Decker, G.

    1996-07-01

    With the successful commissioning and achievement of significant milestones at both the 7-GeV Advanced Photon Source (APS) and the 1.5- GeV Advanced Light Source (ALS) at Lawrence Berkeley National Laboratory, synchrotron radiation research capability in the United States holds the promise of many important discoveries in the decade to come. An overview of current accelerator commissioning performance at the American third-generation light sources, state-of-the-art developments at first- and second-generation sources, and a preview of fourth-generation source progress is presented.

  16. Variable-Period Undulators for Synchrotron Radiation

    Energy Technology Data Exchange (ETDEWEB)

    Shenoy, Gopal; Lewellen, John; Shu, Deming; Vinokurov, Nikolai

    2005-02-22

    A new and improved undulator design is provided that enables a variable period length for the production of synchrotron radiation from both medium-energy and high energy storage rings. The variable period length is achieved using a staggered array of pole pieces made up of high permeability material, permanent magnet material, or an electromagnetic structure. The pole pieces are separated by a variable width space. The sum of the variable width space and the pole width would therefore define the period of the undulator. Features and advantages of the invention include broad photon energy tunability, constant power operation and constant brilliance operation.

  17. Exposure from residual radiation after synchrotron shutdown

    Energy Technology Data Exchange (ETDEWEB)

    Moyers, M.F. [Proton Therapy, Inc., Colton, CA 92324 (United States)], E-mail: mfmoyers@roadrunner.com; Lesyna, D.A. [Optivus Proton Therapy, San Bernardino, CA 92408 (United States)

    2009-02-15

    Personnel exposure from residual radiation present after an accelerator is shutdown for preventative or corrective maintenance is an important aspect that governs the manner in which a light ion facility can be used. This radiation is not only a safety issue for maintenance personnel but also can affect the patient throughput of the facility. Measurements were made with survey instruments around the synchrotron accelerator at the Loma Linda University Proton Treatment Facility and personnel dosimetry records of maintenance staff were reviewed. Results showed that the residual radiation in this facility design is very low, does not significantly impact maintenance staff safety, and has placed no restrictions on patient throughput.

  18. Synchrotron-based in vivo tracking of implanted mammalian cells

    Energy Technology Data Exchange (ETDEWEB)

    Hall, C.J. [Monash University, School of Physics, Melbourne, Victoria 3800 (Australia)], E-mail: chris.hall@sync.monash.edu.au; Schueltke, E. [University of Saskatchewan, Department of Anatomy and Cell Biology, 107 Wiggins Road, Saskatoon, SK S7N 5E5 (Canada)], E-mail: e.schultke@usask.ca; Rigon, L. [Abdus Salam International Centre for Theoretical Physics (ICTP), Strada Costiera 11, 34014 Trieste (Italy)], E-mail: luigi.rigon@ts.infn.it; Ataelmannan, K.; Rigley, S. [University of Saskatchewan, Department of Anatomy and Cell Biology, 107 Wiggins Road, Saskatoon, SK S7N 5E5 (Canada); Menk, R. [Sincrotrone Trieste ScpA, S.S. 14 km, 163.5, 34012 Basovizza, TS (Italy)], E-mail: ralf.menk@elettra.trieste.it; Arfelli, F. [Department of Physics, University of Trieste, INFN, Via Valerio 2, 34127 Trieste (Italy)], E-mail: arfelli@trieste.infn.it; Tromba, G. [Sincrotrone Trieste ScpA, S.S. 14 km, 163.5, 34012 Basovizza, TS (Italy); Pearson, S. [IXC UK, Elm House, 351 Bristol Road, Edgbaston Park, Birmingham B5 7SW (United Kingdom)], E-mail: sarah.pearson@ixc-uk.com; Wilkinson, S. [Cranfield University, Department of Materials and Medical Science, Shrivenham, Swindon SN6 8LA (United Kingdom)], E-mail: k.d.rogers@cranfield.ac.uk; Round, A. [EMBL Hamburg c/o DESY, Notkestrasse 85, 22603 Hamburg (Germany)], E-mail: around@embl-hamburg.de; Crittell, S. [Liverpool University, Department of Physics, PO Box 147, Liverpool L69 3BX (United Kingdom)], E-mail: stc@ns.ph.liv.ac.uk; Griebel, R.; Juurlink, B.H.J. [University of Saskatchewan, Department of Anatomy and Cell Biology, 107 Wiggins Road, Saskatoon, SK S7N 5E5 (Canada)

    2008-12-15

    We have developed an X-ray imaging protocol that permits 3D visualisation of a small number of implanted cells within bulk tissue. The cells are marked using natural endocytosis of inert gold nano-particles. The resulting local increase in electron density allows high imaging contrast to be obtained from small clusters of these marked cells. Using this technique we have imaged C6 glioma cells within the brain of a model animal. The cells were marked by exposing them to colloidal gold incorporated in the growth media. Gold-loaded glioma cells were implanted into the brains of adult male Wistar rats. After tumours had been allowed to develop for up to 2 weeks, the animals were sacrificed and images of the intact cranium were acquired at the SYRMEP imaging station on the Elettra synchrotron in Italy. Computed tomography was performed using mixed absorption and phase contrast techniques at an X-ray energy of 24 keV. In the resulting volume datasets the tumour bulk is clearly visible and the infiltrating nature of the malignant growth is well demonstrated. Although the protocol was developed using this particular model of malignant brain tumour, it is believed that it will be possible to use it with other cell lines.

  19. The present status of high-pressure research at Beijing Synchrotron Radiation Facility

    CERN Document Server

    Liu, J; Li, Y C

    2002-01-01

    The present status of high-pressure research at Beijing Synchrotron Radiation Facility is reported. A ten-poles wiggler beamline provides a white beam for investigating samples using a diamond anvil cell. In situ energy-dispersive diffraction is used to determine the pressure-induced phase transitions and equations of state. High pressure can be stably applied by a stepper-motorized loading system with a strain sensor. Some megabar experiments have been carried out without damage on diamonds. Improved beam collimation reduces the background and eliminates gasket scatter. Some research and future developments are also presented.

  20. Biological equivalent dose studies for dose escalation in the stereotactic synchrotron radiation therapy clinical trials

    Energy Technology Data Exchange (ETDEWEB)

    Prezado, Y.; Fois, G.; Edouard, M.; Nemoz, C.; Renier, M.; Requardt, H.; Esteve, F.; Adam, JF.; Elleaume, H.; Bravin, A., E-mail: prezado@esrf.fr [ID17 Biomedical Beamline, European Synchrotron Radiation Facility (ESRF), 6 rue Jules Horowitz, BP 220, 38043 Grenoble Cedex (France)

    2009-03-15

    Synchrotron radiation is an innovative tool for the treatment of brain tumors. In the stereotactic synchrotron radiation therapy (SSRT) technique a radiation dose enhancement specific to the tumor is obtained. The tumor is loaded with a high atomic number (Z) element and it is irradiated in stereotactic conditions from several entrance angles. The aim of this work was to assess dosimetric properties of the SSRT for preparing clinical trials at the European Synchrotron Radiation Facility (ESRF). To estimate the possible risks, the doses received by the tumor and healthy tissues in the future clinical conditions have been calculated by using Monte Carlo simulations (PENELOPE code). The dose enhancement factors have been determined for different iodine concentrations in the tumor, several tumor positions, tumor sizes, and different beam sizes. A scheme for the dose escalation in the various phases of the clinical trials has been proposed. The biological equivalent doses and the normalized total doses received by the skull have been calculated in order to assure that the tolerance values are not reached.

  1. Low temperature barriers with heat interceptor wells for in situ processes

    Science.gov (United States)

    McKinzie, II, Billy John

    2008-10-14

    A system for reducing heat load applied to a frozen barrier by a heated formation is described. The system includes heat interceptor wells positioned between the heated formation and the frozen barrier. Fluid is positioned in the heat interceptor wells. Heat transfers from the formation to the fluid to reduce the heat load applied to the frozen barrier.

  2. Analytical Fits to the Synchrotron Functions

    CERN Document Server

    Fouka, M

    2013-01-01

    Accurate fitting formulae to the synchrotron function, $F(x)$, and its complementary function, $G(x)$, are performed and presented. The corresponding relative errors are less than $0.26\\%$ and $0.035\\%$ for $F(x) $ and $G(x)$, respectively. To this aim we have, first, fitted the modified Bessel functions, $K_{5/3}(x)$ and $K_{2/3}(x)$. For all the fitted functions, the general fit expression is the same, and is based on the well known asymptotic forms for low and large $x$-values for each function. It consists of multiplying each asymptotic form by a function that tends to unity or zero for low and large $x$-values. Simple formulae are suggested in this paper, depending on adjustable parameters. The latter have been determined by adopting the Levenberg-Marquardt algorithm. The proposed formulae should be of great utility and simplicity for computing spectral powers and the degree of polarization for the synchrotron radiation, both for laboratory and astrophysical applications.

  3. Physics design of SSRF synchrotron radiation security

    Institute of Scientific and Technical Information of China (English)

    XU Yi; DAI Zhi-Min; LIU Gui-Min

    2009-01-01

    High brightness of SSRF brings about synchrotron radiation security problems,which will be solved in physics design.The main radiations are generated from bending magnets and insertion devices.Since the fact that radiation power and radiating area are different in these two kinds of synchrotron radiation,the arrangements of photon absorbers,diaphragms and other vacuum components need to be treated distinctively.In addition.SSRF interlock protection threshold is defined and the beam orbit in the straight line is limited.Hence.beam orbit in the bending magnets and IDs are also restricted by the threshold.The orbit restriction is calculated and helps us to arrange the vacuum components.In this paper,beam orbit distortion restricted by interlock protection threshold,radiation power,radiation angle and illuminating area are calculated.From the calculation results,the physics designs in manufacture and installation vacuum components are put forward.By commissioning,it is shown that physics requirements are met rigidly in the engineering process.

  4. Injection Efficiency Monitor for the Australian Synchrotron

    Directory of Open Access Journals (Sweden)

    Rassool R. P.

    2012-10-01

    Full Text Available The Australian Synchrotron AS is moving towards a continuous injection mode called top-up. During top-up the linac and booster synchrotron injection system will be in continuous operation rather than usedevery eight hours the way they are used at present. In order to monitor the performance of the injection system areal-time injection efficiency monitoring system has been developed. The system consists of several Fast CurrentTransformers [1] and matching digitisers [2] and is designed to count every beam pulse and measure the transmission efficiency through the whole accelerator complex. After calibrating the system using a properly matchedFaraday Cup at the electron gun, a transmission efficiency is then calculated at each stage of transferring the beamfrom 90 keV out of the gun to 3 GeV in the storage ring. The system is used to optimise the injection process inorder to maximise the injection efficiency and as an early warning system when equipment starts to fail and theinjection efficiency decreases.

  5. Mapping prehistoric ghosts in the synchrotron

    Energy Technology Data Exchange (ETDEWEB)

    Edwards, N.P.; Wogelius, R.A. [University of Manchester, School of Earth, Atmospheric, and Environmental Sciences, Manchester (United Kingdom); University of Manchester, Williamson Research Centre for Molecular Environmental Science, Manchester (United Kingdom); Bergmann, U. [SLAC National Accelerator Laboratory, Linac Coherent Light Source, Menlo Park, CA (United States); Larson, P. [Black Hills Institute of Geological Research, Inc., Hill City, SD (United States); Sellers, W.I. [University of Manchester, Faculty of Life Sciences, Manchester (United Kingdom); Manning, P.L. [University of Manchester, School of Earth, Atmospheric, and Environmental Sciences, Manchester (United Kingdom); University of Manchester, Williamson Research Centre for Molecular Environmental Science, Manchester (United Kingdom); University of Pennsylvania, Department of Earth and Environmental Science, Philadelphia, PA (United States)

    2013-04-15

    The detailed chemical analysis of fossils has the potential to reveal great insight to the composition, preservation and biochemistry of ancient life. Such analyses would ideally identify, quantify, and spatially resolve the chemical composition of preserved bone and soft tissue structures, but also the embedding matrix. Mapping the chemistry of a fossil in situ can place constraints on mass transfer between the enclosing matrix and the preserved organism(s), and therefore aid in distinguishing taphonomic processes from original chemical zonation remnant within the fossils themselves. Conventional analytical methods, such as scanning electron microscopy (SEM) and pyrolysis-gas chromatography/mass spectrometry (Py-GC/MS) have serious limitations in this case, primarily, an inability to provide large (i.e., decimeter) scale chemical maps. Additionally, vacuum chamber size and the need for destructive sampling preclude analysis of large and precious fossil specimens. However, the recent development of Synchrotron Rapid Scanning X-ray Fluorescence (SRS-XRF) at the Stanford Synchrotron Radiation Lightsource (SSRL) allows the non-destructive chemical analysis and imaging of major, minor, and trace element concentrations of large paleontological and archeological specimens in rapid scanning times. Here we present elemental maps of a fossil reptile produced using the new SRS-XRF method. Our results unequivocally show that preserved biological structures are not simply impressions or carbonized remains, but possess a remnant of the original organismal biochemistry. We show that SRS-XRF is a powerful new tool for the study of paleontological and archaeological samples. (orig.)

  6. Enhanced analysis of biomaterials by synchrotron diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Rogers, K. [Cranfield Postgraduate Medical School, Cranfield University, Shrivenham, Swindon, Wiltshire, SN6 8LA (United Kingdom)]. E-mail: k.d.rogers@cranfield.ac.uk; Etok, S. [Cranfield Postgraduate Medical School, Cranfield University, Shrivenham, Swindon, Wiltshire, SN6 8LA (United Kingdom); Broadhurst, A. [Cranfield Postgraduate Medical School, Cranfield University, Shrivenham, Swindon, Wiltshire, SN6 8LA (United Kingdom); Scott, R. [Biomet-Europe, Dorcan Way, Swindon, Wiltshire, SN3 5HY (United Kingdom)

    2005-08-11

    There is an increasing body of evidence that prosthetic implants based upon titanium alloys attain improved performance when coated with calcium hydroxyapatite (HAP). Such coatings appear to promote osteointegration and bone in-growth. Plasma spraying is the most frequently employed route to coating fabrication. Detailed chemical and structural characterisation of these coatings is essential for (i) coating technology development (ii) ensuring consistent material quality and (iii) assessing coating performance. The work presented here employed combined conventional powder diffraction and glancing angle synchrotron diffraction to examine the in vitro performance of apatite coatings formed by plasma spraying. Coatings were exposed to simulated body fluid and foetal calf serum, and changes to the coating chemistry and structure determined. A new analysis method, synchrotron depth profiling tomography, has been applied to obtain structural features through the coating depth. The dissolution and re-precipitation behaviour of the coatings was found to be significantly different for each media. For the first time, it has been possible to identify and quantify the formation of a nanocrystalline, carbonated HAP phase. It has been possible to simultaneously model all coating phases apparent within the X-ray diffraction data and thus quantify changes to film composition. DPT has also revealed subtle changes in coating features with depth and these may have a significant impact on coating dissolution. The findings are discussed in the context of kinematic models for the coating behaviour and implications for the performance of such coatings in vivo.

  7. Berkeley Lab's ALS generates femtosecond synchrotron radiation

    CERN Document Server

    Robinson, A L

    2000-01-01

    A team at Berkeley's Advanced Light Source has shown how a laser time-slicing technique provides a path to experiments with ultrafast time resolution. A Lawrence Berkeley National Laboratory team has succeeded in generating 300 fs pulses of synchrotron radiation at the ALS synchrotron radiation machine. The team's members come from the Materials Sciences Division (MSD), the Center for Beam Physics in the Accelerator and Fusion Research Division and the Advanced Light Source (ALS). Although this proof-of principle experiment made use of visible light on a borrowed beamline, the laser "time-slicing" technique at the heart of the demonstration will soon be applied in a new bend magnet beamline that was designed specially for the production of femtosecond pulses of X-rays to study long-range and local order in condensed matter with ultrafast time resolution. An undulator beamline based on the same technique has been proposed that will dramatically increase the flux and brightness. The use of X-rays to study the c...

  8. Magnetic Field Structure from Synchrotron Polarization

    CERN Document Server

    Beck, R

    2006-01-01

    Total magnetic fields in spiral galaxies, as observed through their total synchrotron emission, are strongest (up to \\simeq 30\\mu G) in the spiral arms. The degree of radio polarization is low; the field in the arms must be mostly turbulent or tangled. Polarized synchrotron emission shows that the resolved regular fields are generally strongest in the interarm regions (up to \\simeq 15\\mu G), sometimes forming 'magnetic arms' parallel to the optical arms. The field structure is spiral in almost every galaxy, even in flocculent and bright irregular types which lack spiral arms. The observed large-scale patterns of Faraday rotation in several massive spiral galaxies reveal coherent regular fields, as predicted by dynamo models. However, in most galaxies observed so far no simple patterns of Faraday rotation could be found. Either many dynamo modes are superimposed and cannot be resolved by present-day telescopes, or most of the apparently regular field is in fact anisotropic random, with frequent reversals, due ...

  9. Beam halo collimation in heavy ion synchrotrons

    Science.gov (United States)

    Strašík, I.; Prokhorov, I.; Boine-Frankenheim, O.

    2015-08-01

    This paper presents a systematic study of the halo collimation of ion beams from proton up to uranium in synchrotrons. The projected Facility for Antiproton and Ion Research synchrotron SIS100 is used as a reference case. The concepts are separated into fully stripped (e.g., 238U92+ ) and partially stripped (e.g., 238U28+ ) ion collimation. An application of the two-stage betatron collimation system, well established for proton accelerators, is intended also for fully stripped ions. The two-stage system consists of a primary collimator (a scattering foil) and secondary collimators (bulky absorbers). Interaction of the particles with the primary collimator (scattering, momentum losses, and nuclear interactions) was simulated by using fluka. Particle-tracking simulations were performed by using mad-x. Finally, the dependence of the collimation efficiency on the primary ion species was determined. The influence of the collimation system adjustment, lattice imperfections, and beam parameters was estimated. The concept for the collimation of partially stripped ions employs a thin stripping foil in order to change their charge state. These ions are subsequently deflected towards a dump location using a beam optical element. The charge state distribution after the stripping foil was obtained from global. The ions were tracked by using mad-x.

  10. Synchrotrons for hadron therapy: Part I

    CERN Document Server

    Badano, L; Bryant, P; Crescenti, M; Holy, P; Knaus, P; Maier, A; Pullia, M; Rossi, S

    1999-01-01

    The treatment of cancer with accelerator beams has a long history with betatrons, linacs, cyclotrons and now synchrotrons being exploited for this purpose. Treatment techniques can be broadly divided into the use of spread-out beams and scanned 'pencil' beams. The Bragg-peak behaviour of hadrons makes them ideal candidates for the latter. The combination of precisely focused 'pencil' beams with controllable penetration (Bragg peak) and high, radio-biological efficiency (light ions) opens the way to treating the more awkward tumours that are radio-resistant, complex in shape and lodged against critical organs. To accelerate light ions (probably carbon) with pulse-to-pulse energy variation, a synchrotron is the natural choice. The beam scanning system is controlled via an on-line measurement of the particle flux entering the patient and, for this reason, the beam spill must be extended in time (seconds) by a slow-extraction scheme. The quality of the dose intensity profile ultimately depends on the uniformity o...

  11. Synchrotrons for hadron therapy, part 1

    CERN Document Server

    Badano, L; Bryant, P J; Crescenti, M; Holy, P; Knaus, P; Maier, A T; Pullia, M; Rossi, S

    1999-01-01

    The treatment of cancer with accelerator beams has a long history with linacs, cyclotrons and now synchrotrons being exploited for this purpose. Treatment techniques can be broadly divided into the use of spread-out beams and scanned 'pencil' beams. The Bragg-peak behaviour of hadrons makes them ideal candidates for the latter. The combination of precisely focused 'pencil' beams with controllable penetration (Bragg peak) and high, radio-biological efficiency (light ions) opens the way to treating the more awkward tumours that are radio-resistant, complex in shape and lodged against critical organs. To accelerate light ions (probably carbon) with pulse-to-pulse energy variation, a synchrotron is the natural choice. The beam scanning system is controlled via an on-line measurement of the particle flux entering the patient and, for this reason, the beam spill must be extended in time (seconds) by a slow-extraction scheme. The quality of the dose intensity profile ultimately depends on the uniformity of the beam ...

  12. Ferroelectrics under the Synchrotron Light: A Review

    Directory of Open Access Journals (Sweden)

    Luis E. Fuentes-Cobas

    2015-12-01

    Full Text Available Currently, an intensive search for high-performance lead-free ferroelectric materials is taking place. ABO3 perovskites (A = Ba, Bi, Ca, K and Na; B = Fe, Nb, Ti, and Zr appear as promising candidates. Understanding the structure–function relationship is mandatory, and, in this field, the roles of long- and short-range crystal orders and interactions are decisive. In this review, recent advances in the global and local characterization of ferroelectric materials by synchrotron light diffraction, scattering and absorption are analyzed. Single- and poly-crystal synchrotron diffraction studies allow high-resolution investigations regarding the long-range average position of ions and subtle global symmetry break-downs. Ferroelectric materials, under the action of electric fields, undergo crystal symmetry, crystallite/domain orientation distribution and strain condition transformations. Methodological aspects of monitoring these processes are discussed. Two-dimensional diffraction clarify larger scale ordering: polycrystal texture is measured from the intensities distribution along the Debye rings. Local order is investigated by diffuse scattering (DS and X-ray absorption fine structure (XAFS experiments. DS provides information about thermal, chemical and displacive low-dimensional disorders. XAFS investigation of ferroelectrics reveals local B-cation off-centering and oxidation state. This technique has the advantage of being element-selective. Representative reports of the mentioned studies are described.

  13. Progress of the Synchrotron Light Source ALBA

    CERN Document Server

    Einfeld, Dieter; Campmany, Josep; Muñoz, Marc; Pont, Montserrat

    2005-01-01

    ALBA will be a third generation synchrotron light source built in Spain near Barcelona. Commissioning of the storage ring is foreseen to start at the end of 2008. The design phase of ALBA is almost completed and the first components are ready to be ordered. A 100 MeV LINAC will inject electrons into a nominal energy booster synchrotron of similar circumference as the storage ring, so that both accelerators will share the same tunnel. The storage ring, working at 3 GeV with a circumference of 268.8 m, has been designed for a maximum current of 400 mA. The lattice is based on an extended DBA structure and has a nominal emittance of 4 nm.rad.The machine has a four fold symmetry with 4 long straight sections (8 m), 12 medium (4.2 m) and 8 short (2.6 m). This report concentrates on recent design developments, component choices and current status. Another paper at this conference deals with accelerator physics issues.

  14. ANKA - Service-oriented synchrotron radiation facility

    Energy Technology Data Exchange (ETDEWEB)

    Babayan, Ruben Albert; Birkel, Ingrid; Buth, Gernot [Forschungszentrum Karlsruhe, ANKA Project Group, Karlsruhe (DE)] [and others

    1999-06-01

    ANKA is a 2.5 GeV synchrotron radiation facility under construction at Forschungszentrum Karlsruhe. ANKA is based on a 2.5 GeV electron storage ring injected from a 500 MeV booster synchrotron and a 50 MeV racetrack microtron. Nominal circulating electron current will be 400 mA. The facility is scheduled to become operational in fall 2000. ANKA will deliver photons predominantly in the hard X-ray range but it will also feature both XUV and infrared beamlines. So far, all beamlines will use bending magnets as sources, while provision is made to install appropriate insertion devices later on. ANKA has a novel mission which is characterised by giving preference to providing service to customers while maintaining a significant fraction of research work. ANKA will offer full service in X-ray lithography, mainly for micro- and nanofabrication, and in analysing and investigating non-destructively various structural, mechanical, chemical, electronic, magnetic, and molecular properties of samples and components. (author)

  15. Analytical fits to the synchrotron functions

    Institute of Scientific and Technical Information of China (English)

    Mourad Fouka; Saad Ouichaoui

    2013-01-01

    Accurate fitting formulae to the synchrotron function,F(x),and its complementary function,G(x),are performed and presented.The corresponding relative errors are less than 0.26% and 0.035% for F(x) and G(x),respectively.To this end we have,first,fitted the modified Bessel functions,K5/3(x) and K2/3(x).For all the fitted functions,the general fit expression is the same,and is based on the well known asymptotic forms for low and large values of x for each function.It consists of multiplying each asymptotic form by a function that tends to unity or zero for low and large values of x.Simple formulae are suggested in this paper,depending on adjustable parameters.The latter have been determined by adopting the Levenberg-Marquardt algorithm.The proposed formulae should be of great utility and simplicity for computing spectral powers and the degree of polarization for synchrotron radiation,both for laboratory and astrophysical applications.

  16. Efficient computation of coherent synchrotron radiation in a rectangular chamber

    Science.gov (United States)

    Warnock, Robert L.; Bizzozero, David A.

    2016-09-01

    We study coherent synchrotron radiation (CSR) in a perfectly conducting vacuum chamber of rectangular cross section, in a formalism allowing an arbitrary sequence of bends and straight sections. We apply the paraxial method in the frequency domain, with a Fourier development in the vertical coordinate but with no other mode expansions. A line charge source is handled numerically by a new method that rids the equations of singularities through a change of dependent variable. The resulting algorithm is fast compared to earlier methods, works for short bunches with complicated structure, and yields all six field components at any space-time point. As an example we compute the tangential magnetic field at the walls. From that one can make a perturbative treatment of the Poynting flux to estimate the energy deposited in resistive walls. The calculation was motivated by a design issue for LCLS-II, the question of how much wall heating from CSR occurs in the last bend of a bunch compressor and the following straight section. Working with a realistic longitudinal bunch form of r.m.s. length 10.4 μ m and a charge of 100 pC we conclude that the radiated power is quite small (28 W at a 1 MHz repetition rate), and all radiated energy is absorbed in the walls within 7 m along the straight section.

  17. Primary energy savings using heat storage for biomass heating systems

    Directory of Open Access Journals (Sweden)

    Mitrović Dejan M.

    2012-01-01

    Full Text Available District heating is an efficient way to provide heat to residential, tertiary and industrial users. The heat storage unit is an insulated water tank that absorbs surplus heat from the boiler. The stored heat in the heat storage unit makes it possible to heat even when the boiler is not working, thus increasing the heating efficiency. In order to save primary energy (fuel, the boiler operates on nominal load every time it is in operation (for the purpose of this research. The aim of this paper is to analyze the water temperature variation in the heat storage, depending on the heat load and the heat storage volume. Heat load is calculated for three reference days, with average daily temperatures from -5 to 5°C. The primary energy savings are also calculated for those days in the case of using heat storage in district heating.[Projekat Ministarstva nauke Republike Srbije, br. TR 33051: The concept of sustainable energy supply of settlements with energy efficient buildings

  18. How Can Synchrotron Radiation Techniques Be Applied for Detecting Microstructures in Amorphous Alloys?

    Directory of Open Access Journals (Sweden)

    Gu-Qing Guo

    2015-11-01

    Full Text Available In this work, how synchrotron radiation techniques can be applied for detecting the microstructure in metallic glass (MG is studied. The unit cells are the basic structural units in crystals, though it has been suggested that the co-existence of various clusters may be the universal structural feature in MG. Therefore, it is a challenge to detect microstructures of MG even at the short-range scale by directly using synchrotron radiation techniques, such as X-ray diffraction and X-ray absorption methods. Here, a feasible scheme is developed where some state-of-the-art synchrotron radiation-based experiments can be combined with simulations to investigate the microstructure in MG. By studying a typical MG composition (Zr70Pd30, it is found that various clusters do co-exist in its microstructure, and icosahedral-like clusters are the popular structural units. This is the structural origin where there is precipitation of an icosahedral quasicrystalline phase prior to phase transformation from glass to crystal when heating Zr70Pd30 MG.

  19. Low frequency interference between short synchrotron radiation sources

    Directory of Open Access Journals (Sweden)

    F. Méot

    2001-06-01

    Full Text Available A recently developed analytical formalism describing low frequency far-field synchrotron radiation (SR is applied to the calculation of spectral angular radiation densities from interfering short sources (edge, short magnet. This is illustrated by analytical calculation of synchrotron radiation from various assemblies of short dipoles, including an “isolated” highest density infrared SR source.

  20. A synchrotron radiation facility for x-ray astronomy

    DEFF Research Database (Denmark)

    Hall, C.J.; Lewis, R.A.; Christensen, Finn Erland

    1997-01-01

    A proposal for an x-ray optics test facility based at a synchrotron radiation source is presented. The facility would incorporate a clean preparation area, and a large evacuable test area. The advantages of using a synchrotron as the source of the test radiation are discussed. These include the a...

  1. Synchrotron radiation in art and archaeology SRA 2005

    Energy Technology Data Exchange (ETDEWEB)

    Pollard, A.M.; Janssens, K.; Artioli, G.; Young, M.L.; Casadio, F.; Schnepp, S.; Marvin, J.; Dunand, D.C.; Almer, J.; Fezzaa, K.; Lee, W.K.; Haeffner, D.R.; Reguer, S.; Dillmann, Ph.; Mirambet, F.; Susini, J.; Lagarde, P.; Pradell, T.; Molera, J.; Brunetti, B.; D' acapito, F.; Maurizio, C.; Mazzoldi, P.; Padovani, S.; Sgamellotti, A.; Garges, F.; Etcheverry, M.P.; Flank, A.M.; Lagarde, P.; Marcus, M.A.; Scheidegger, A.M.; Grolimund, D.; Pallot-Frossard, I.; Smith, A.D.; Jones, M.; Gliozzo, E.; Memmi-Turbanti, I.; Molera, J.; Vendrell, M.; Mcconachie, G.; Skinner, T.; Kirkman, I.W.; Pantos, E.; Wallert, A.; Kanngiesser, B.; Hahn, O.; Wilke, M.; NekaT, B.; Malzer, W.; Erko, A.; Chalmin, E.; Vignaud, C.; Farges, F.; Susini, J.; Menu, M.; Sandstrom, M.; Cotte, M.; Kennedy, C.J.; Wess, T.J.; Muller, M.; Murphy, B.; Roberts, M.A.; Burghammer, M.; Riekel, C.; Gunneweg, J.; Pantos, E.; Dik, J.; Tafforeau, P.; Boistel, R.; Boller, E.; Bravin, A.; Brunet, M.; Chaimanee, Y.; Cloetens, P.; Feist, M.; Hoszowska, J.; Jaeger, J.J.; Kay, R.F.; Lazzari, V.; Marivaux, L.; Nel, A.; Nemoz, C.; Thibault, X.; Vignaud, P.; Zabler, S.; Sciau, P.; Goudeau, P.; Tamura, N.; Doormee, E.; Kockelmann, W.; Adriaens, A.; Ryck, I. de; Leyssens, K.; Hochleitner, B.; Schreiner, M.; Drakopoulos, M.; Snigireva, I.; Snigirev, A.; Sanchez Del Rio, M.; Martinetto, P.; Dooryhee, E.; Suarez, M.; Sodo, A.; Reyes-Valerio, C.; Haro Poniatowski, E.; Picquart, M.; Lima, E.; Reguera, E.; Gunneweg, J.; Reiche, I.; Berger, A.; Bevers, H.; Duval, A

    2005-07-01

    Materials - bones, artifacts, artwork,.... - lie at the heart of both archaeology and art conservation. Synchrotron radiation techniques provide powerful ways to interrogate these records of our physical and cultural past. In this workshop we will discuss and explore the current and potential applications of synchrotron radiation science to problems in archaeology and art conservation. This document gathers the abstracts of the presentations.

  2. Supporting facilities for synchrotron high-pressure high/low temperature research at HPCAT, APS

    Science.gov (United States)

    Sinogeikin, S. V.; Rod, E.; Kenney-Benson, C.; Shen, G.

    2012-12-01

    High Pressure Collaborative Access Team (HPCAT) is dedicated to advancing cutting-edge, multidisciplinary, high-pressure science and technology using synchrotron radiation at Sector 16 of the Advanced Photon Source (APS) of Argonne National Laboratory. At HPCAT an array of novel x-ray diffraction and spectroscopic techniques has been integrated with high pressure and extreme temperature instrumentation. Over the last several years a number of supporting facilities have been developed and implemented to expand the available P-T range of the experimental conditions, increase efficiency and productivity of the beamlines, improve the quality of experimental data, and integrate additional methods of sample characterization with synchrotron investigations. A considerable effort was put into developing instrumentation which allows remote and automatic pressure control in diamond anvil cells (DACs) during synchrotron experiments. We have developed a number mechanical devices (gearboxes) for controlling pressure in DACs at a variety pressure and temperature conditions. Such devices can be used for automated data collection along predefined P-T paths. We also designed and implemented a double-diaphragm (membrane) pressure control system is capable of adopting many types of DAC and allows accurate sample pressure control at a variety of PT conditions - from cryogenic to laser heating experiments. These remote pressure control instrumentation can be easily integrated into cryostats and devices for high-temperature measurements at high pressure. In addition to existing cryogenic facilities, we have designed and implemented a variety of compact cryostats for different synchrotron techniques (powder and single crystal diffraction, inelastic scattering, etc.) The cryostats can accommodate a variety of standard and novel DACs, can be easily integrated with remote pressure control devices, and allow for high-pressure measurements at temperatures down to 2-4 K. We have designed a

  3. Comments on Landau damping due to synchrotron frequency spread

    Energy Technology Data Exchange (ETDEWEB)

    Ng, K.Y.; /Fermilab

    2005-01-01

    An inductive/space-charge impedance shifts the synchrotron frequency downwards above/below transition, but it is often said that the coherent synchrotron frequency of the bunch is not shifted in the rigid-dipole mode. On the other hand, the incoherent synchrotron frequency due to the sinusoidal rf always spreads in the downward direction. This spread will therefore not be able to cover the coherent synchrotron frequency, implying that there will not be any Landau damping no matter how large the frequency spread is. By studying the dispersion relation, it is shown that the above argument is incorrect, and there will be Landau damping if there is sufficient frequency spread. The main reason is that the coherent frequency of the rigid-dipole mode will no longer remain unshifted in the presence of a synchrotron frequency spread.

  4. Status of the booster synchrotron for SPring-8

    Science.gov (United States)

    Suzuki, H.; Yonehara, H.; Aoki, T.; Tani, N.; Kaneda, T.; Ueyama, Y.; Sasaki, Y.; Nagafuchi, T.; Hayashi, S.; Yokomizo, H.

    1995-02-01

    The specification and the layout of the booster synchrotron for SPring-8 were decided. The synchrotron is designed to accelerate electron or positron beams from 1 to 8 GeV with a repetition cycle of 1 Hz. The construction of the synchrotron was started in 1993. First, one bending, one quadrupole, and one sextupole magnet were made and the results of the magnetic field measurement were acquired. Two septum, one bump, and one kicker magnets for the beam extraction have been made, the field measurement and a few improvements have progressed. The high power test of the first rf cavity was finished successfully. The calibration test of the button position monitor with the signal treatment circuits is advanced now. The residual components of the synchrotron are designed and constructed, and the commissioning of the synchrotron will start in 1996. This paper presents the first measurement of each component.

  5. A novel epitaxially grown LSO-based thin-film scintillator for micro-imaging using hard synchrotron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Douissard, P.A.; Martin, T.; Chevalier, V.; Rack, A. [European Synchrotron Radiat Facil, F-38043 Grenoble, (France); Cecilia, A.; Baumbach, T.; Rack, A. [Karlsruhe Inst Technol ANKA, D-76021 Karlsruhe, (Germany); Couchaud, M. [CEA LETI, F-38054 Grenoble, (France); Dupre, K. [FEE GmbH, D-55743 Idar Oberstein, (Germany); Kuhbacher, M. [Helmholtz Zentrum Berlin Mat and Energie, D-14109 Berlin, (Germany)

    2010-07-01

    The efficiency of high-resolution pixel detectors for hard X-rays is nowadays one of the major criteria which drives the feasibility of imaging experiments and in general the performance of an experimental station for synchrotron-based microtomography and radiography. Here the luminescent screen used for the indirect detection is focused on in order to increase the detective quantum efficiency a novel scintillator based on doped Lu{sub 2}SiO{sub 5} (LSO), epitaxially grown as thin film via the liquid phase epitaxy technique. It is shown that, by using adapted growth and doping parameters as well as a dedicated substrate, the scintillation behaviour of a LSO-based thin crystal together with the high stopping power of the material allows for high-performance indirect X-ray detection. In detail, the conversion efficiency, the radioluminescence spectra, the optical absorption spectra under UV/visible-light and the afterglow are investigated. A set-up to study the effect of the thin-film scintillator's temperature on its conversion efficiency is described as well it delivers knowledge which is important when working with higher photon flux densities and the corresponding high heat load on the material. Additionally, X-ray imaging systems based on different diffraction-limited visible-light optics and CCD cameras using among others LSO-based thin film are compared. Finally, the performance of the LSO thin film is illustrated by imaging a honey bee leg, demonstrating the value of efficient high-resolution computed tomography for life sciences. (authors)

  6. 3D Detectors for Synchrotron Applications

    CERN Document Server

    Pennicard, D

    2009-01-01

    3D detectors are a novel variety of photodiode radiation detector, invented by Parker, Kenney and Segal (1997). Instead of having n- and p-type contacts on the front and back surfaces of a silicon substrate, like a standard photodiode, they have columns of doped material passing through the thickness of the silicon. This structure means that the detector can combine a reasonable substrate thickness with a very small electrode spacing, resulting in a low depletion voltage, fast charge collection and low charge sharing. These detectors have a couple of promising applications. Their fast charge collection and low depletion voltage should make them very radiation-tolerant. So, they could be used for future particle physics experiments at the Super Large Hadron Collider (SLHC), where high levels of radiation damage are expected. Also, their low charge sharing means they could potentially improve X-ray diffraction measurements at synchrotrons such as Diamond Light Source. This would allow these experiments, for exa...

  7. Brightness of synchrotron radiation from wigglers

    CERN Document Server

    Geloni, Gianluca; Saldin, Evgeni

    2014-01-01

    According to literature, while calculating the brightness of synchrotron radiation from wigglers, one needs to account for the so called `depth-of-field' effects. In fact, the particle beam cross section varies along the wiggler. It is usually stated that the effective photon source size increases accordingly, while the brightness is reduced. Here we claim that this is a misconception originating from an analysis of the wiggler source based on geometrical arguments, regarded as almost self-evident. According to electrodynamics, depth-of-field effects do not exist: we demonstrate this statement both theoretically and numerically, using a well-known first-principle computer code. This fact shows that under the usually accepted approximations, the description of the wiggler brightness turns out to be inconsistent even qualitatively. Therefore, there is a need for a well-defined procedure for computing the brightness from a wiggler source. We accomplish this task based on the use of a Wigner function formalism. I...

  8. Silicon Pixel Detectors for Synchrotron Applications

    CERN Document Server

    Stewart, Graeme Douglas

    Recent advances in particle accelerators have increased the demands being placed on detectors. Novel detector designs are being implemented in many different areas including, for example, high luminosity experiments at the LHC or at next generation synchrotrons. The purpose of this thesis was to characterise some of these novel detectors. The first of the new detector types is called a 3D detector. This design was first proposed by Parker, Kenney and Segal (1997). In this design, doped electrodes are created that extend through the silicon substrate. When compared to a traditional photodiode with electrodes on the opposing surfaces, the 3D design can combine a reasonable detector thickness with a small electrode spacing resulting in fast charge collection and limited charge sharing. The small electrode spacing leads to the detectors having lower depletion voltages. This, combined with the fast collection time, makes 3D detectors a candidate for radiation hard applications. These applications include the upgra...

  9. Quadrupole magnet for a rapid cycling synchrotron

    Energy Technology Data Exchange (ETDEWEB)

    Witte, H. [Brookhaven National Lab. (BNL), Upton, NY (United States); Berg, J. S. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2015-05-03

    Rapid Cycling Synchrotrons (RCS) feature interleaved warm and cold dipole magnets; the field of the warm magnets is used to modulate the average bending field depending on the particle energy. It has been shown that RCS can be an attractive option for fast acceleration of particles, for example, muons, which decay quickly. In previous studies it was demonstrated that in principle warm dipole magnets can be designed which can provide the required ramp rates, which are equivalent to frequencies of about 1 kHz. To reduce the losses it is beneficial to employ two separate materials for the yoke; it was also shown that by employing an optimized excitation coil geometry the eddy current losses are acceptable. In this paper we show that the same principles can be applied to quadrupole magnets targeting 30 T/m with a repetition rate of 1kHz and good field quality.

  10. Real-time animation of synchrotron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Shintake, Tsumoru E-mail: shintake@spring8.or.jp

    2003-07-11

    New mathematical method has been developed to compute radiation field from a moving charge in free space. It is not based on the retarded potential or its derivation [R.Y. Tsien, Picture of dynamic electric fields, Am. J. Phys. 40, 1972]. It solves conformal mapping of electric field lines based on the following two facts: (1) once a wave is emitted from a particle, it propagates as a spherical wave. The wavelet (a part of the wave-front) runs with speed of the light, and does not change its direction, (2) the initial direction of the wavelet is determined by the Lorentz transformation between the electron-rest-frame to the laboratory frame, which gives the light aberration effect. 2D radiation simulator has been developed based on this method, which simulates synchrotron, undulator and dipole radiation in time domain [T. Shintake, Simulation of field lines generated by a moving charge, private note 1984 March 19 at KEK, not published].

  11. Optical substrate materials for synchrotron radiation beamlines

    Energy Technology Data Exchange (ETDEWEB)

    Howells, M.R. [Lawrence Berkeley National Lab., CA (United States). Advanced Light Source; Paquin, R.A. [Univ. of Arizona, Tucson, AZ (United States). Optical Sciences Center

    1997-06-01

    The authors consider the materials choices available for making optical substrates for synchrotron radiation beam lines. They find that currently the optical surfaces can only be polished to the required finish in fused silica and other glasses, silicon, CVD silicon carbide, electroless nickel and 17-4 PH stainless steel. Substrates must therefore be made of one of these materials or of a metal that can be coated with electroless nickel. In the context of material choices for mirrors they explore the issues of dimensional stability, polishing, bending, cooling, and manufacturing strategy. They conclude that metals are best from an engineering and cost standpoint while the ceramics are best from a polishing standpoint. They then give discussions of specific materials as follows: silicon carbide, silicon, electroless nickel, Glidcop{trademark}, aluminum, precipitation-hardening stainless steel, mild steel, invar and superinvar. Finally they summarize conclusions and propose ideas for further research.

  12. Helical magnetized wiggler for synchrotron radiation laser

    CERN Document Server

    Wang Mei; Hirshfield, J L

    1999-01-01

    A helical magnetized iron wiggler has been built for a novel infrared synchrotron radiation laser (SRL) experiment. The wiggler consists of four periods of helical iron structure immersed in a solenoid field. This wiggler is to impart transverse velocity to a prebunched 6 MeV electron beam, and thus to obtain a desired high orbit pitch ratio for the SRL. Field tapering at beam entrance is considered and tested on a similar wiggler. Analytic and simulated characteristics of wigglers of this type are discussed and the performance of the fabricated wigglers is demonstrated experimentally. A 4.7 kG peak field was measured for a 6.4 mm air gap and a 5.4 cm wiggler period at a 20 kG solenoid field. The measured helical fields compare favorably with the analytical solution. This type of helical iron wigglers has the potential to be scaled to small periods with strong field amplitude.

  13. A guide to synchrotron radiation science

    CERN Document Server

    Sato, Shigeru; Munro, Ian; Lodha, G S

    2015-01-01

    Synchrotron Radiation (SR), as a light source is now in use around the world to provide brilliant radiation from the infrared into the soft and hard X-ray regions. It is an indispensible and essential tool to establish the physic-chemical characteristics of materials and surfaces from an atomic and molecular view point. It is being applied to topics which range from mineralogy to protein crystallography, embracing research in areas from the physical to the life sciences. This new guide is a concise yet comprehensive and easily readable introduction to an expanding area of science. It presents in a readily assimilable form the basic concepts of SR science from its generation principles, through source design and operation to the principles of instruments for SR exploitation followed by a survey of its actual applications in selected research fields, including spectroscopy, diffractometry, microanalysis and chemical processing.

  14. Brightness of synchrotron radiation from wigglers

    Energy Technology Data Exchange (ETDEWEB)

    Geloni, Gianluca [European XFEL GmbH, Hamburg (Germany); Kocharyan, Vitali; Saldin, Evgeni [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany)

    2014-12-15

    According to literature, while calculating the brightness of synchrotron radiation from wigglers, one needs to account for the so called 'depth-of-field' effects. In fact, the particle beam cross section varies along the wiggler. It is usually stated that the effective photon source size increases accordingly, while the brightness is reduced. Here we claim that this is a misconception originating from an analysis of the wiggler source based on geometrical arguments, regarded as almost self-evident. According to electrodynamics, depth-of-field effects do not exist: we demonstrate this statement both theoretically and numerically, using a well-known first-principle computer code. This fact shows that under the usually accepted approximations, the description of the wiggler brightness turns out to be inconsistent even qualitatively. Therefore, there is a need for a well-defined procedure for computing the brightness from a wiggler source. We accomplish this task based on the use of a Wigner function formalism. In the geometrical optics limit computations can be performed analytically. Within this limit, we restrict ourselves to the case of the beam size-dominated regime, which is typical for synchrotron radiation facilities in the X-ray wavelength range. We give a direct demonstration of the fact that the apparent horizontal source size is broadened in proportion to the beamline opening angle and to the length of the wiggler. While this effect is well-understood, a direct proof appears not to have been given elsewhere. We consider the problem of the calculation of the wiggler source size by means of numerical simulations alone, which play the same role of an experiment. We report a significant numerical disagreement between exact calculations and approximations currently used in literature.

  15. Time-resolved spectroscopy using synchrotron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Poliakoff, E.D.

    1979-08-01

    Work performed at the Stanford Synchrotron Radiation Laboratory (SSRL) is reported. The timing characteristics of the SPEAR beam (pulse width less than or equal to 0.4 nsec, pulse repetition period = 780 nsec) were exploited to determine dynamic behavior of atomic, molecular, excimeric, and photodissociative gas-phase species excited by vacuum-ultraviolet (VUV) radiation. Fast fluorescence timing measurements were done to determine excited-state lifetimes of Kr and Xe. Pressure-dependent timing studies on Xe gas at higher concentrations demonstrated some of the problems associated with previous kinetic modeling of the Xe/sub 2/ system. It was found that even qualitative agreement of observed Xe/sub 2/ lifetimes as a function of pressure required the assumption that the radiative lifetime was a strong function of internuclear separation. The radiative decays of chemically unstable fragments, CN* (B/sup 2/..sigma../sup +/) and XeF* (B/sup 2/..sigma../sup +/ and C/sup 2/ Pi/sub 3/2//), were studied by pulsed photodissociation of stable parent compounds, ICN and XeF/sub 2/. When the polarization of the CN* (B/sup 2/..sigma../sup +/) fragment fluorescence was measured, it was found to be non-zero and strongly dependent on excitation wavelength. This polarization is related to the symmetry of the photodissociative surface via a classical model, and the variations in the polarization with wavelength is attributed to symmetry and lifetime effects of a predissociating parent molecule. Despite the drawbacks of limited availability and low radiation flux, synchrotron radiation is definitely a useful spectroscopic tool for VUV studies of gas-phase systems.

  16. Synchrotron hard X-ray imaging of shock-compressed metal powders

    Science.gov (United States)

    Rutherford, Michael E.; Chapman, David J.; Collinson, Mark A.; Jones, David R.; Music, Jasmina; Stafford, Samuel J. P.; Tear, Gareth R.; White, Thomas G.; Winters, John B. R.; Drakopoulos, Michael; Eakins, Daniel E.

    2015-06-01

    This poster will present the application of a new, high-energy (50 to 250 keV) synchrotron X-ray radiography technique to the study of shock-compressed granular materials. Following plate-impact loading, transmission radiography was used to quantitatively observe the compaction and release processes in a range of high-Z metal powders (e.g. Fe, Ni, Cu). By comparing the predictions of 3D numerical models initialized from X-ray tomograms-captured prior to loading-with experimental results, this research represents a new approach to refining mesoscopic compaction models. The authors gratefully acknowledge the ongoing support of Imperial College London, EPSRC, STFC and the Diamond Light Source, and AWE Plc.

  17. Iron load

    Directory of Open Access Journals (Sweden)

    Filippo Cassarà

    2013-03-01

    Full Text Available Recent research addressed the main role of hepcidin in the regulation of iron metabolism. However, while this mechanism could be relevant in causing iron load in Thalassemia Intermedia and Sickle-Cell Anemia, its role in Thalassemia Major (TM is marginal. This is mainly due to the high impact of transfusional requirement into the severe increase of body iron. Moreover, the damage of iron load may be worsened by infections, as HCV hepatitis, or liver and endocrinological damage. One of the most relevant associations was found between splenectomy and increase of risk for mortality due,probably, to more severe iron load. These issues suggest as morbidity and mortality of this group of patients they do not depend only by our ability in controlling heart damage but even in preventing or treating particular infections and complications. This finding is supported by the impairment of survival curves in patients with complications different from heart damage. However, because, during recent years different direct and indirect methods to detect iron overload in patients affected by secondary hemochromatosis have been implemented, our ability to maintain under control iron load is significantly improved. Anyway, the future in iron load management remains to be able to have an iron load map of our body for targeting chelation and other medical treatment according to the single organ damage.

  18. XP CEN/TS 14825 (June 2004). Air conditioners, liquid chilling packages and heat pumps with electrically driven compressors for space heating and cooling. Testing and rating at part load conditions; XP CEN/TS 14825 Juin 2004 Climatiseurs, groupes refroidisseurs de liquide et pompes a chaleur avec compresseur entraine par moteur electrique pour le chauffage et la refrigeration. Essais et determination des caracteristiques a charge partielle

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2004-06-01

    This technical specification covers the tests of air conditioners, heat pumps and liquid chillers in partial load conditions. It specifies the terms and definitions, the testing methods, the test report and the calculation method when the power reduction is due to the cyclic operation of the apparatus or to a power reduction of the compressor(s). The power reductions linked with the temperatures or with the system are excluded. (J.S.)

  19. Advances and synergy of high pressure sciences at synchrotron sources

    Energy Technology Data Exchange (ETDEWEB)

    Liu, H.; Ehm, L.; Duffy, T.; Crichton, W.; Aoki, K.

    2009-01-01

    Introductory overview to the special issue papers on high-pressure sciences and synchrotron radiation. High-pressure research in geosciences, materials science and condensed matter physics at synchrotron sources is experiencing growth and development through synergistic efforts around the world. A series of high-pressure science workshops were organized in 2008 to highlight these developments. One of these workshops, on 'Advances in high-pressure science using synchrotron X-rays', was held at the National Synchrotron Light Source (NSLS), Brookhaven National Laboratory, USA, on 4 October 2008. This workshop was organized in honour of Drs Jingzhu Hu and Quanzhong Guo in celebration of their retirement after up to 18 years of dedicated service to the high-pressure community as beamline scientists at X17 of NSLS. Following this celebration of the often unheralded role of the beamline scientist, a special issue of the Journal of Synchrotron Radiation on Advances and Synergy of High-Pressure Sciences at Synchrotron Sources was proposed, and we were pleased to invite contributions from colleagues who participated in the workshop as well as others who are making similar efforts at synchrotron sources worldwide.

  20. High heat flux loop heat pipes

    Science.gov (United States)

    North, Mark T.; Sarraf, David B.; Rosenfeld, John H.; Maidanik, Yuri F.; Vershinin, Sergey

    1997-01-01

    Loop Heat Pipes (LHPs) can transport very large thermal power loads, over long distances, through flexible, small diameter tubes and against high gravitational heads. While recent LHPs have transported as much as 1500 W, the peak heat flux through a LHP's evaporator has been limited to about 0.07 MW/m2. This limitation is due to the arrangement of vapor passages next to the heat load which is one of the conditions necessary to ensure self priming of the device. This paper describes work aimed at raising this limit by threefold to tenfold. Two approaches were pursued. One optimized the vapor passage geometry for the high heat flux conditions. The geometry improved the heat flow into the wick and working fluid. This approach also employed a finer pored wick to support higher vapor flow losses. The second approach used a bidisperse wick material within the circumferential vapor passages. The bidisperse material increased the thermal conductivity and the evaporative surface area in the region of highest heat flux, while providing a flow path for the vapor. Proof-of-concept devices were fabricated and tested for each approach. Both devices operated as designed and both demonstrated operation at a heat flux of 0.70 MW/m2. This performance exceeded the known state of the art by a factor of more than six for both conventional heat pipes and for loop heat pipes using ammonia. In addition, the bidisperse-wick device demonstrated boiling heat transfer coefficients up to 100,000 W/m2.K, and the fine pored device demonstrated an orientation independence with its performance essentially unaffected by whether its evaporator was positioned above, below or level with the condenser.