WorldWideScience

Sample records for heat capacity uvelichenie

  1. Frequency-dependent heat capacity

    DEFF Research Database (Denmark)

    Behrens, Claus Flensted

    The frequency–dependent heat capacity of super-cooled glycerol near the glass transition is measured using the 3w detection technique. An electrical conducting thin film with a temperature–dependent electrical resistance is deposited on a substrate. The thin film is used simultaneously as a heater...

  2. Heat capacity of spinning plasma

    Science.gov (United States)

    Geyko, V. I.; Fisch, N. J.

    2017-10-01

    Equilibrium thermodynamics properties, such as heat capacity and adiabatic axial and radial compressibility of a rotating plasma column are studied. These properties depend on rotation speed, charge density, external magnetic field strength and electron-ion mass ratio. Plasma rotation serves as an additional energy storage, hence, yields to increased heat capacity. It also leads to charge separation that changes plasma density distribution due to electrostatic interaction and Lorentz force and therefore modifies thermodynamic properties. The obtained results can provide limits and optimal regimes for radial compression of z-pinch type structures and optimize energy deposition profile. This work was supported by NNSA DE-NA0001836 and DE-NA0002948 and by NSF Contract No. PHY-1506122.

  3. Heat capacity and heat of dissociation of methane hydrates

    Energy Technology Data Exchange (ETDEWEB)

    Rueff, R.M.; Sloan, E.D.; Yesavage, V.F.

    1988-09-01

    The objective of this study was to determine the heat capacity and heat of dissociation of methane hydrates. A technique has been devised which circumvents the two major problems encountered in measuring gas hydrate heat capacity: the need to impose a mechanical pressure during the measurement and the need to have an absolutely pure hydrate sample. The technique was shown to be successful utilizing high-pressure, constant-volume cells in a differential scanning calorimeter.

  4. Heat Capacity Mapping Mission: 1978-1980

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — NASA's Heat Capacity Mapping Mission (HCMM) project collected Earth data in the visible and thermal bands between April 1978 and September 1980. This was an...

  5. On the Specific Heat Capacity of CuO Nanofluid

    OpenAIRE

    Le-Ping Zhou; Bu-Xuan Wang; Xiao-Feng Peng; Xiao-Ze Du; Yong-Ping Yang

    2010-01-01

    This paper reviews briefly the definition of heat capacity and clarifies the defined specific heat capacity and volumetric heat capacity. The specific heat capacity and volumetric heat capacity, with our measured experimental data for CuO nanofluids, are discussed as an illustrating example. The result indicates that the specific heat capacity of CuO nanofluid decreases gradually with increasing volume concentration of nanoparticles. The measurement and the prediction from the thermal equilib...

  6. Meteorite heat capacities: Results to date

    Science.gov (United States)

    Consolmagno, G.; Macke, R.; Britt, D.

    2014-07-01

    Heat capacity is an essential thermal property for modeling asteroid internal metamorphism or differentiation, and dynamical effects like YORP or Yarkovsky perturbations. We have developed a rapid, inexpensive, and non-destructive method for measuring the heat capacity of meteorites at low temperature [1]. A sample is introduced into a dewar of liquid nitrogen and an electronic scale measures the amount of nitrogen boiled away as the sample is cooled from the room temperature to the liquid nitrogen temperature; given the heat of vaporization of liquid nitrogen, one can then calculate the heat lost from the sample during the cooling process. Note that heat capacity in this temperature range is a strong function of temperature, but this functional relation is essentially the same for all materials; the values we determine are equivalent to the heat capacity of the sample at 175 K. To correct for systematic errors, samples of laboratory-grade quartz are measured along with the meteorite samples. To date, more than 70 samples of more than 50 different meteorites have been measured in this way, including ordinary chondrites [1], irons [2], basaltic achondrites [3], and a limited number of carbonaceous chondrites [1]. In general, one can draw a number of important conclusions from these results. First, the heat capacity of a meteorite is a function of its mineral composition, independent of shock, metamorphism, or other physical state. Second, given this relation, heat capacity can be strongly altered by terrestrial weathering. Third, the measurement of heat capacity in small (less than 1 g) samples as done typically by commercial systems runs a serious risk of giving misleading results for samples that are heterogeneous on scales of tens of grams or more. Finally, we demonstrate that heat capacity is a useful tool for determining and classifying a sample, especially if used in conjunction with other intrinsic variables such as grain density and magnetic susceptibility

  7. Residential Variable-Capacity Heat Pumps Sized to Heating Loads

    Energy Technology Data Exchange (ETDEWEB)

    Munk, Jeffrey D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Jackson, Roderick K. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Odukomaiya, Adewale [Georgia Inst. of Technology, Atlanta, GA (United States); Gehl, Anthony C. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2014-01-01

    Variable capacity heat pumps are an emerging technology offering significant energy savings potential and improved efficiency. With conventional single-speed systems, it is important to appropriately size heat pumps for the cooling load as over-sizing would result in cycling and insufficient latent capacity required for humidity control. These appropriately sized systems are often under-sized for the heating load and require inefficient supplemental electric resistance heat to meet the heating demand. Variable capacity heat pumps address these shortcomings by providing an opportunity to intentionally size systems for the dominant heating season load without adverse effects of cycling or insufficient dehumidification in the cooling season. This intentionally-sized system could result in significant energy savings in the heating season, as the need for inefficient supplemental electric resistance heat is drastically reduced. This is a continuation of a study evaluating the energy consumption of variable capacity heat pumps installed in two unoccupied research homes in Farragut, a suburb of Knoxville, Tennessee. In this particular study, space conditioning systems are intentionally sized for the heating season loads to provide an opportunity to understand and evaluate the impact this would have on electric resistance heat use and dehumidification. The results and conclusions drawn through this research are valid and specific for portions of the Southeastern and Midwestern United States falling in the mixed-humid climate zone. While other regions in the U.S. do not experience this type of climate, this work provides a basis for, and can help understand the implications of other climate zones on residential space conditioning energy consumption. The data presented here will provide a framework for fine tuning residential building EnergyPlus models that are being developed.

  8. MEASUREMENT OF SPECIFIC HEAT CAPACITY OF SALTSTONE

    Energy Technology Data Exchange (ETDEWEB)

    Harbour, J; Vickie Williams, V

    2008-09-29

    One of the goals of the Saltstone variability study is to identify (and quantify the impact of) the operational and compositional variables that control or influence the important processing and performance properties of Saltstone grout mixtures. The heat capacity of the Saltstone waste form is one of the important properties of Saltstone mixes that was last measured at SRNL in 1997. It is therefore important to develop a core competency for rapid and accurate analysis of the specific heat capacity of the Saltstone mixes in order to quantify the impact of compositional and operational variations on this property as part of the variability study. The heat capacity, coupled with the heat of hydration data obtained from isothermal calorimetry for a given Saltstone mix, can be used to predict the maximum temperature increase in the cells within the vaults of the Saltstone Disposal Facility (SDF). The temperature increase controls the processing rate and the pour schedule. The maximum temperature is also important to the performance properties of the Saltstone. For example, in mass pours of concrete or grout of which Saltstone is an example, the maximum temperature increase and the maximum temperature difference (between the surface and the hottest location) are controlled to ensure durability of the product and prevent or limit the cracking caused by the thermal gradients produced during curing. This report details the development and implementation of a method for the measurement of the heat capacities of Saltstone mixes as well as the heat capacities of the cementitious materials of the premix and the simulated salt solutions used to batch the mixes. The developed method utilizes the TAM Air isothermal calorimeter and takes advantage of the sophisticated heat flow measurement capabilities of the instrument. Standards and reference materials were identified and used to validate the procedure and ensure accuracy of testing. Heat capacities of Saltstone mixes were

  9. Classical fluids of negative heat capacity

    Energy Technology Data Exchange (ETDEWEB)

    Landsberg, P.T. (Southampton Univ., (United Kingdom). Faculty of Mathematical Studies); Woodard, R.P. (Florida Univ., Gainesville, FL (United States). Dept. of Physics)

    1992-06-01

    It is shown that new parameters X can be defined such that the heat capacity C{sub X} {equivalent to} T({partial derivative}S/{partial derivative}T)X is negative, even when the canonical ensemble (i.e. at fixed T = ({partial derivative}U/{partial derivative}S) and Y {ne} X) is stable. As examples we treat black body radiation and general gas systems with nonsingular {kappa}{sub T}. For the case of a simple ideal gas we even exhibit an apparatus which enforces a constraint X(p,V) = const. that makes C{sub X} < 0. Since it is possible to invent constraints for which canonically stable systems have negative heat capacity we speculate that it may also be possible to infer the statistical mechanics of canonically unstable systems - for which even the traditional heat capacities are negative - by imposing constraints that stabilize the associated, inoncanonical ensembles.

  10. Classical fluids of negative heat capacity

    Energy Technology Data Exchange (ETDEWEB)

    Landsberg, P.T. [Southampton Univ., (United Kingdom). Faculty of Mathematical Studies; Woodard, R.P. [Florida Univ., Gainesville, FL (United States). Dept. of Physics

    1992-06-01

    It is shown that new parameters X can be defined such that the heat capacity C{sub X} {equivalent_to} T({partial_derivative}S/{partial_derivative}T)X is negative, even when the canonical ensemble (i.e. at fixed T = ({partial_derivative}U/{partial_derivative}S) and Y {ne} X) is stable. As examples we treat black body radiation and general gas systems with nonsingular {kappa}{sub T}. For the case of a simple ideal gas we even exhibit an apparatus which enforces a constraint X(p,V) = const. that makes C{sub X} < 0. Since it is possible to invent constraints for which canonically stable systems have negative heat capacity we speculate that it may also be possible to infer the statistical mechanics of canonically unstable systems - for which even the traditional heat capacities are negative - by imposing constraints that stabilize the associated, inoncanonical ensembles.

  11. High-Capacity Heat-Pipe Evaporator

    Science.gov (United States)

    Oren, J. A.; Duschatko, R. J.; Voss, F. E.; Sauer, L. W.

    1989-01-01

    Heat pipe with cylindrical heat-input surface has higher contact thermal conductance than one with usual flat surface. Cylindrical heat absorber promotes nearly uniform flow of heat into pipe at all places around periphery of pipe, helps eliminate hotspots on heat source. Lugs in aluminum pipe carry heat from outer surface to liquid oozing from capillaries of wick. Liquid absorbs heat, evaporates, and passes out of evaporator through interlug passages.

  12. Electron heat capacity and lattice properties of Americium

    Science.gov (United States)

    Povzner, A. A.; Filanovich, A. N.; Os'kina, V. A.; Volkov, A. G.

    2013-12-01

    The temperature dependence of the electron heat capacity of americium is calculated using the concepts on the electronic structure and magnetic properties of this element. The Debye temperature, the thermal expansion coefficient, and the bulk modulus of americium are determined on the basis of the results of calculations and experimental data on heat capacity.

  13. How to Measure Heat Capacity at Low Temperatures

    Science.gov (United States)

    Ventura, Guglielmo; Perfetti, Mauro

    This chapter is devoted to the description of calorimetric techniques used to measure heat capacity of solids: pulse heat calorimetry (Sect. 2.3), relaxation calorimetry (Sect. 2.4), dual slope calorimetry (Sect. 2.5), a.c. calorimetry (Sect. 2.6), differential scanning calorimetry (Sect. 2.7). Examples of measurements of heat capacity are reported in Sects. 2.3 and 2.4.

  14. The capacity credit of micro-combined heat and power

    Energy Technology Data Exchange (ETDEWEB)

    Hawkes, A.D. [Centre for Energy Policy and Technology, Imperial College London, Exhibition Road, London SW7 2AZ (United Kingdom); Leach, M.A. [Centre for Environmental Strategy, Faculty of Engineering, University of Surrey, Guildford GU2 7XH (United Kingdom)

    2008-04-15

    This article is concerned with development of a methodology to determine the capacity credit of micro-combined heat and power (micro-CHP), and application of the method for the UK. Capacity credit is an important parameter in electricity system planning because it measures the amount of conventional generation that would be displaced by an alternative technology. Firstly, a mathematical formulation is presented. Capacity credit is then calculated for three types of micro-CHP units - Stirling engine, internal combustion engine, and fuel cell systems - operating under various control strategies. It is found that low heat-to-power ratio fuel cell technologies achieve the highest capacity credit of approximately 85% for a 1.1 GW penetration when a heat-led control strategy is applied. Higher heat-to-power ratio Stirling engine technology achieves approximately 33% capacity credit for heat-led operation. Low heat-to-power ratio technologies achieve higher capacity credit because they are able to continue operating even when heat demand is relatively low. Capacity credit diminishes as penetration of the technology increases. Overall, the high capacity credit of micro-CHP contributes to the viewpoint that the technology can help meet a number of economic and environmental energy policy aims. (author)

  15. Device for Measuring Heat Capacities of Microcalorimeter Absorber Materials

    Science.gov (United States)

    Kotsubo, Vincent; Beall, James; Ullom, Joel

    2009-12-01

    We are developing a device for measuring the heat capacity of candidate absorber materials for gamma-ray microcalorimeters with the goal of finding materials with low heat capacity and high stopping power to improve detector efficiency. To date, only Sn has been effective as an absorber, and speculation is that other materials suffer from anomalously high heat capacities at low temperatures. The key component of the measurement device is a 17 mm×17 mm low heat capacity silicon platform suspended by Kevlar fibers designed for accepting 1 g to 2 g samples, and whose heat capacity can be characterized prior to attaching a sample. The platform has a thin film Pd/Au heater deposited directly on the silicon, and a semiconducting thermometer bonded to the surface. The heat capacity is determined from C = Gτ, where G is the in-situ measured conductance and x is the measured temperature decay time from a step change in applied heat. For a platform without samples, decay periods on the order of 0.3 to 0.05 seconds were measured. With samples, decay periods of several seconds are projected, allowing good resolution of the heat capacities. Several thermometers were tested in an effort to find one with the optimum characteristics for measuring platform temperatures. These included a commercial thick-film Ruthenium-oxide surface-mount resistor, a germanium NTD, and a zirconium oxy-nitride thin-film thermometer.

  16. Heat-capacity measurements on small samples: The hybrid method

    NARCIS (Netherlands)

    Klaasse, J.C.P.; Brück, E.H.

    2008-01-01

    A newly developed method is presented for measuring heat capacities on small samples, particularly where thermal isolation is not sufficient for the use of the traditional semiadiabatic heat-pulse technique. This "hybrid technique" is a modification of this heat-pulse method in case the temperature

  17. Saturated-liquid heat capacity calculation of alkanes

    Directory of Open Access Journals (Sweden)

    JOVAN D. JOVANOVIC

    2005-12-01

    Full Text Available An empirical model for the calculation of the heat capacity of alkanes is recommended. This model was tested and compared to known models (Luria–Benson and Rizicka–Domalski using 68 sets with 1155 literature experimental heat capacity data of 39 alkanes. The obtained results indicate that the newmodel is slightly better tha the existing models, especially near the critical point.

  18. Prediction of nanofluids properties: the density and the heat capacity

    Science.gov (United States)

    Zhelezny, V. P.; Motovoy, I. V.; Ustyuzhanin, E. E.

    2017-11-01

    The results given in this report show that the additives of Al2O3 nanoparticles lead to increase the density and decrease the heat capacity of isopropanol. Based on the experimental data the excess molar volume and the excess molar heat capacity were calculated. The report suggests new method for predicting the molar volume and molar heat capacity of nanofluids. It is established that the values of the excess thermodynamic functions are determined by the properties and the volume of the structurally oriented layers of the base fluid molecules near the surface of nanoparticles. The heat capacity of the structurally oriented layers of the base fluid is less than the heat capacity of the base fluid for given parameters due to the greater regulation of its structure. It is shown that information on the geometric dimensions of the structured layers of the base fluid near nanoparticles can be obtained from data on the nanofluids density and at ambient temperature – by the dynamic light scattering method. For calculations of the nanofluids heat capacity over a wide range of temperatures a new correlation based on the extended scaling is proposed.

  19. Heat capacity of GdNi sub 5

    Energy Technology Data Exchange (ETDEWEB)

    Szewczyk, A. (Inst. of Physics, Polish Academy of Sciences, Warsaw (Poland)); Radwanski, R.J.; Franse, J.J.M.; Nakotte, H. (Natuurkundig Lab., Univ. van Amsterdam (Netherlands))

    1992-02-01

    The heat capacity of GdNi{sub 5} was measured from 1.3 to 48 K in a fixed magnetic field (up to 5 T). The electronic, phonon, and magnetic contributions were separated. Temperature dependences of magnetic specific heat and entropy were calculated in the molecular field approximation. They are in good agreement with the experimental results. (orig.).

  20. Separation of Power and Capacity In latent Heat Energy Storage

    OpenAIRE

    Pointner, H.; Steinmann, W.D.; van Eck, M.; Bachelier, C.

    2015-01-01

    The state-of-the-art latent heat energy storage system is equipped with aluminum fins at the heat exchanger pipes in order to compensate the low thermal conductivity of the phase change material (PCM). The necessary amount of fins is directly coupled to the capacity of the storage system, what makes larger systems expensive. The PCMflux concept is developed in order to realize both a controllable and a possibly more cost effectivelatent heat storage system. These aims are addressed by separat...

  1. Heat capacity measurements on high T sub c superconductors

    CERN Document Server

    Oezcan, S

    1998-01-01

    temperature interval. The phase transition jump increases with the increasing of oxygen amount in the CuO sub 2 layers. The hight of the jump is varying from 1.5% to 3.5% of the total specific heat which is the nature of the bulk superconductivity. The small coherence length increases fluctuation effects and also causes the dependence of superconducting properties on structural defects. The fluctuation effects on the heat capacity of YBCO is investigated on the sample that shows clear superconducting properties. In this work, a heat capacity measurement system which has high sensitivity and reproducibility designed and constructed. The investigation of the effect of oxygen stoichiometry on the superconducting properties of high T sub c superconductors was aimed. For this purpose electrical resistivity, magnetic susceptibility and heat capacity experiment were performed. The constructed system is a computerized adiabatic calorimeter which has temperature resolution of about 0.1 mk and operates in the temperatu...

  2. Indoor temperatures for calculating room heat loss and heating capacity of radiant heating systems combined with mechanical ventilation systems

    DEFF Research Database (Denmark)

    Wu, Xiaozhou; Olesen, Bjarne W.; Fang, Lei

    2016-01-01

    In this study, a typical office room with a radiant heating system and a mechanical ventilation system was selected as the research subject. Indoor temperature formulas for calculating the room heat loss (including transmission heat loss and ventilation heat loss) and heating capacity of the hybrid...... for calculating ventilation heat loss and heating capacity of radiant heating systems combined with mechanical ventilation systems. (C) 2015 Elsevier B.V. All rights reserved....... change rates on the indoor temperatures were performed using the proposed model. When heated surface temperatures and air change rates were from 21.0 to 29.0 degrees C and from 0.5 to 4.0 h-1, the indoor temperatures for calculating the transmission heat loss and ventilation heat loss were between 20...

  3. Reductions in labour capacity from heat stress under climate warming

    Science.gov (United States)

    Dunne, John P.; Stouffer, Ronald J.; John, Jasmin G.

    2013-06-01

    A fundamental aspect of greenhouse-gas-induced warming is a global-scale increase in absolute humidity. Under continued warming, this response has been shown to pose increasingly severe limitations on human activity in tropical and mid-latitudes during peak months of heat stress. One heat-stress metric with broad occupational health applications is wet-bulb globe temperature. We combine wet-bulb globe temperatures from global climate historical reanalysis and Earth System Model (ESM2M) projections with industrial and military guidelines for an acclimated individual's occupational capacity to safely perform sustained labour under environmental heat stress (labour capacity)--here defined as a global population-weighted metric temporally fixed at the 2010 distribution. We estimate that environmental heat stress has reduced labour capacity to 90% in peak months over the past few decades. ESM2M projects labour capacity reduction to 80% in peak months by 2050. Under the highest scenario considered (Representative Concentration Pathway 8.5), ESM2M projects labour capacity reduction to less than 40% by 2200 in peak months, with most tropical and mid-latitudes experiencing extreme climatological heat stress. Uncertainties and caveats associated with these projections include climate sensitivity, climate warming patterns, CO2 emissions, future population distributions, and technological and societal change.

  4. Maximum Power Point Characteristics of Generalized Heat Engines with Finite Time and Finite Heat Capacities

    Directory of Open Access Journals (Sweden)

    Abhishek Khanna

    2012-01-01

    Full Text Available We revisit the problem of optimal power extraction in four-step cycles (two adiabatic and two heat-transfer branches when the finite-rate heat transfer obeys a linear law and the heat reservoirs have finite heat capacities. The heat-transfer branch follows a polytropic process in which the heat capacity of the working fluid stays constant. For the case of ideal gas as working fluid and a given switching time, it is shown that maximum work is obtained at Curzon-Ahlborn efficiency. Our expressions clearly show the dependence on the relative magnitudes of heat capacities of the fluid and the reservoirs. Many previous formulae, including infinite reservoirs, infinite-time cycles, and Carnot-like and non-Carnot-like cycles, are recovered as special cases of our model.

  5. Negative heat capacities in central Xe+Sn reactions

    Energy Technology Data Exchange (ETDEWEB)

    Le Neindre, N.; Bougault, R.; Gulminelli, F. [Laboratoire de Physique Corpusculaire, IN2P3-CNRS, ISMRA et Universite, 14 - Caen (France)] [and others

    2000-02-01

    In this study the fluctuation method is applied to the 32-50 A.MeV Xe + Sn central collisions detected with the INDRA multidetector. This method based on kinetic energy fluctuations allows the authors to provide information on the liquid gas phase transition in nuclear multifragmentation. In the case of Xe + Sn central reactions a divergence in the total heat capacity is observed. This divergence corresponds to large fluctuations on the detected fragment partitions. A negative heat capacity branch is measured and so tends to confirm the observation of a first order phase transition in heavy-ion collisions. (A.C.)

  6. Development of a high capacity variable conductance heat pipe.

    Science.gov (United States)

    Kosson, R.; Hembach, R.; Edelstein, F.; Loose, J.

    1973-01-01

    The high-capacity, pressure-primed, tunnel-artery wick concept was used in a gas-controlled variable conductance heat pipe. A variety of techniques were employed to control the size of gas/vapor bubbles trapped within the artery. Successful operation was attained with a nominal 6-foot long, 1-inch diameter cold reservoir VCHP using ammonia working fluid and nitrogen control gas. The pipe contained a heat exchanger to subcool the liquid in the artery. Maximum transport capacity with a 46-inch effective length was 1200 watts level (more than 50,000 watt-inches) and 800 watts at 0.5-inch adverse tilt.

  7. On the Einstein-Stern model of rotational heat capacities

    DEFF Research Database (Denmark)

    Dahl, Jens Peder

    1998-01-01

    The Einstein-Stern model for the rotational contribution to the heat capacity of a diatomic gas has recently been resuscitated. In this communication, we show that the apparent success of the model is illusory, because it is based on what has turned out to be an unfortunate comparison with experi......The Einstein-Stern model for the rotational contribution to the heat capacity of a diatomic gas has recently been resuscitated. In this communication, we show that the apparent success of the model is illusory, because it is based on what has turned out to be an unfortunate comparison...

  8. Hybrid heat capacity-moving slab solid-state laser

    Science.gov (United States)

    Stappaerts, Eddy A.

    2005-03-01

    Laser material is pumped and its stored energy is extracted in a heat capacity laser mode at a high duty factor. When the laser material reaches a maximum temperature, it is removed from the lasing region and a subsequent volume of laser material is positioned into the lasing region to repeat the lasing process. The heated laser material is cooled passively or actively outside the lasing region.

  9. The influence of working memory capacity on experimental heat pain.

    Science.gov (United States)

    Nakae, Aya; Endo, Kaori; Adachi, Tomonori; Ikeda, Takashi; Hagihira, Satoshi; Mashimo, Takashi; Osaka, Mariko

    2013-10-01

    Pain processing and attention have a bidirectional interaction that depends upon one's relative ability to use limited-capacity resources. However, correlations between the size of limited-capacity resources and pain have not been evaluated. Working memory capacity, which is a cognitive resource, can be measured using the reading span task (RST). In this study, we hypothesized that an individual's potential working memory capacity and subjective pain intensity are related. To test this hypothesis, we evaluated 31 healthy participants' potential working memory capacity using the RST, and then applied continuous experimental heat stimulation using the listening span test (LST), which is a modified version of the RST. Subjective pain intensities were significantly lower during the challenging parts of the RST. The pain intensity under conditions where memorizing tasks were performed was compared with that under the control condition, and it showed a correlation with potential working memory capacity. These results indicate that working memory capacity reflects the ability to process information, including precise evaluations of changes in pain perception. In this work, we present data suggesting that changes in subjective pain intensity are related, depending upon individual potential working memory capacities. Individual working memory capacity may be a phenotype that reflects sensitivity to changes in pain perception. Copyright © 2013 American Pain Society. Published by Elsevier Inc. All rights reserved.

  10. Measurement of the specific heat capacity of graphite

    Energy Technology Data Exchange (ETDEWEB)

    Picard, S.; Burns, D.T.; Roger, P

    2006-01-15

    With the objective of implementing graphite calorimetry at the BIPM to measure absorbed dose, an experimental assembly has recently been constructed to measure the specific heat capacity of graphite. A status description of the apparatus and results from the first measurements are given. The outcome is discussed and the experimental uncertainty is reviewed. (authors)

  11. Heat capacity changes in carbohydrates and protein-carbohydrate complexes.

    Science.gov (United States)

    Chavelas, Eneas A; García-Hernández, Enrique

    2009-05-13

    Carbohydrates are crucial for living cells, playing myriads of functional roles that range from being structural or energy-storage devices to molecular labels that, through non-covalent interaction with proteins, impart exquisite selectivity in processes such as molecular trafficking and cellular recognition. The molecular bases that govern the recognition between carbohydrates and proteins have not been fully understood yet. In the present study, we have obtained a surface-area-based model for the formation heat capacity of protein-carbohydrate complexes, which includes separate terms for the contributions of the two molecular types. The carbohydrate model, which was calibrated using carbohydrate dissolution data, indicates that the heat capacity contribution of a given group surface depends on its position in the saccharide molecule, a picture that is consistent with previous experimental and theoretical studies showing that the high abundance of hydroxy groups in carbohydrates yields particular solvation properties. This model was used to estimate the carbohydrate's contribution in the formation of a protein-carbohydrate complex, which in turn was used to obtain the heat capacity change associated with the protein's binding site. The model is able to account for protein-carbohydrate complexes that cannot be explained using a previous model that only considered the overall contribution of polar and apolar groups, while allowing a more detailed dissection of the elementary contributions that give rise to the formation heat capacity effects of these adducts.

  12. Space qualification of high capacity grooved heat pipes

    Energy Technology Data Exchange (ETDEWEB)

    Dubois, M.; Mullender, B.; Druart, J. [SABCA, Societe Anomyme Belgel de Construction Aeronautique (Belgium); Supper, W.; Beddows, A. [ESTEC-The (Netherlands)

    1996-12-31

    Based on the thermal requirements of the future telecommunication satellites, the development of a High Capacity Grooved Heat Pipe (HPG), was contracted by ESA to SABCA leading to an aluminium extruded heat pipe (outer diameter of 25 mm) based on a multi re-entrant grooves design. After an intensive acceptance test campaign whose results showed a good confidence in the design and the fulfillment of the required specifications of heat transport and on tilt capability (experimental maximum heat transport capability of 1500 Watt metres for a vapour temperature of 20 deg C), similar heat pipes have been developed with various outer diameters (11 mm, 15 mm and 20 mm) and with various shapes (circular outer shapes, integrated saddles). Several of these heat pipes were tested during two parabolic flight campaigns, by varying the heat loads during the micro-gravity periods. This HGP heat pipe family is now being submitted to a space qualification program according to ESA standards (ESA PSS-49), both in straight and bent configuration. Within this qualification, the heat pipes are submitted to an extended test campaign including environmental (random/sinus vibration, constant acceleration) and thermal tests (thermal performance, thermal cycle, thermal soak, ageing). (authors) 9 refs.

  13. Investigation of high capacity heat energy storage for building applications

    OpenAIRE

    Ding, Yate

    2014-01-01

    The problems of excessive consumption of fossil resources, oil shortages and greenhouse gas emissions are becoming increasingly severe. Research and development work on new methods of thermal energy storage are imminently required. To effectively store seasonal renewable energy, a novel high capacity heat storage system has been designed and evaluated/validated through laboratory experiments and numerical simulations in this research. The system is driven by direct flow evacuated tube solar c...

  14. Low temperature heat capacity of lutetium and lutetium hydrogen alloys

    Energy Technology Data Exchange (ETDEWEB)

    Thome, David Keith [Iowa State Univ., Ames, IA (United States)

    1977-10-01

    The heat capacity of high purity electrotransport refined lutetium was measured between 1 and 20°K. Results for thetaD were in excellent agreement with theta values determined from elastic constant measurements. The heat capacity of a series of lutetium-hydrogen solid solution alloys was determined and results showed an increase in γ to about 11.3 mJ/g-atom-K2 for hydrogen content increasing from zero to about one atomic percent. Above one percent hydrogen γ decreased with increasing hydrogen contents. The C/T data showed an increase with temperature decreasing below about 2.5°K for samples with 0.1 to 1.5 atomic percent hydrogen. This accounts for a large amount of scatter in thetaD versus hydrogen content in this range. The heat capacity of a bulk sample of lutetium dihydride was measured between 1 and 20°K and showed a large increase in thetaD and a large decrease in ..gamma.. compared to pure lutetium.

  15. High capacity demonstration of honeycomb panel heat pipes

    Science.gov (United States)

    Tanzer, H. J.

    1989-01-01

    The feasibility of performance enhancing the sandwich panel heat pipe was investigated for moderate temperature range heat rejection radiators on future-high-power spacecraft. The hardware development program consisted of performance prediction modeling, fabrication, ground test, and data correlation. Using available sandwich panel materials, a series of subscale test panels were augumented with high-capacity sideflow and temperature control variable conductance features, and test evaluated for correlation with performance prediction codes. Using the correlated prediction model, a 50-kW full size radiator was defined using methanol working fluid and closely spaced sideflows. A new concept called the hybrid radiator individually optimizes heat pipe components. A 2.44-m long hybrid test vehicle demonstrated proof-of-principle performance.

  16. An automated flow calorimeter for heat capacity and enthalpy measurements

    Energy Technology Data Exchange (ETDEWEB)

    Sandarusi, J.A.; Yesavage, V.F.

    1988-11-01

    An automated flow calorimeter has been developed for the measurement of heat capacity and latent enthalpies of fluids at elevated temperatures (300-700 K) and pressure (< 30 MPa) with a design accuracy of 0.1%. The method of measurement is the traditional electrical power input flow calorimeter, utilizing a precision metering pump, which eliminates the need for flow-rate monitoring. The calorimeter cell uses a unique concentric coil design with passive metal radiation shields and active guard heaters to minimize heat leakage, eliminate the traditional constant-temperature bath, and facilitate easy component replacement. An additional feature of the instrument is a complete automation system, greatly simplifying operation of the apparatus. A novel multitasking software scheme allows a single microcomputer simultaneously to control all system temperatures, provide continuous monitoring and updates on system status, and log data. Preliminary results for liquid water mean heat capacities show the equipment to be performing satisfactorily, with data accuracies of better than /plus minus/0.3%. Minor equipment modifications and better thermometry are required to reduce systemic errors and to achieve the designed operational range.

  17. Determination of the heat capacities of Lithium/BCX (bromide chloride in thionyl chloride) batteries

    Science.gov (United States)

    Kubow, Stephen A.; Takeuchi, Kenneth J.; Takeuchi, Esther S.

    1989-01-01

    Heat capacities of twelve different Lithium/BCX (BrCl in thionyl chloride) batteries in sizes AA, C, D, and DD were determined. Procedures and measurement results are reported. The procedure allowed simple, reproducible, and precise determinations of heat capacities of industrially important Lithium/BCX cells, without interfering with performance of the cells. Use of aluminum standards allowed the accuracy of the measurements to be maintained. The measured heat capacities were within 5 percent of calculated heat capacity values.

  18. Anomalous dependence of the heat capacity of supercooled water on pressure and temperature

    Directory of Open Access Journals (Sweden)

    I.A. Stepanov

    2014-01-01

    Full Text Available In some papers, dependences of the isobaric heat capacity of water versus pressure and temperature were obtained. It is shown that these dependences contradict both the dependence of heat capacity on temperature for supercooled water, and an important thermodynamic equation for the dependence of heat capacity on pressure. A possible explanation for this contradiction is proposed.

  19. Cold drink ingestion improves exercise endurance capacity in the heat.

    Science.gov (United States)

    Lee, Jason K W; Shirreffs, Susan M; Maughan, Ronald J

    2008-09-01

    To investigate the effect of drink temperature on cycling capacity in the heat. On two separate trials, eight males cycled at 66 +/- 2% VO2peak (mean +/- SD) to exhaustion in hot (35.0 +/- 0.2 degrees C) and humid (60 +/- 1%) environments. Participants ingested three 300-mL aliquots of either a cold (4 degrees C) or a warm (37 degrees C) drink during 30 min of seated rest before exercise and 100 mL of the same drink every 10 min during exercise. Rectal and skin temperatures, heart rate, and sweat rate were recorded. Ratings of thermal sensation and perceived exertion were assessed. Exercise time was longer (P drink (63.8 +/- 4.3 min) than with the warm drink (52.0 +/- 4.1 min). Rectal temperature fell by 0.5 +/- 0.1 degrees C (P drinks. There was no effect of drink temperature on mean skin temperature at rest (P = 0.870), but mean skin temperature was lower from 20 min during exercise with ingestion of the cold drink than with the warm drink (P drink than with the warm drink (P Drink temperature influenced sweat rate (1.22 +/- 0.34 and 1.40 +/- 0.41 L x h(-1) for the cold and the warm drink, respectively; P drink was ingested. Compared with a drink at 37 degrees C, the ingestion of a cold drink before and during exercise in the heat reduced physiological strain (reduced heat accumulation) during exercise, leading to an improved endurance capacity (23 +/- 6%).

  20. An experimental study of the enhanced heating capacity of an electric heat pump (EHP) using the heat recovered from a gas engine generator

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Cheol Min; Chang, Se Dong [HAC R and D Laboratory, LG Electronics, 327-23 Gasan-Dong, Geumcheon-gu, Seoul 153-802 (Korea); Lee, Jaekeun; Hwang, Yujin [School of Mechanical Engineering, Pusan National University, San 30, Changjeon-Dong, Keumjeong-Ku, Busan 609-735 (Korea)

    2009-11-15

    This paper is concerned with the effect of recovered heat on the heating capacity of an Electric Heat Pump (EHP), which is supplied with electric power and recovered heat from a gas engine generator system. Two methods of supplying recovery heat are examined: (i) to the refrigerant with the discharge line heat exchanger (HEX), and (ii) to the refrigerant of the evaporator with the sub-evaporator. Heating capacity, input power and coefficient of performance (COP) were investigated and compared for each heat recovery method. Conclusively, we found that the second method was most reasonable to recover wasted heat and increased system COP by 215%. (author)

  1. Transient response of a high-capacity heat pipe for Space Station Freedom

    Science.gov (United States)

    Ambrose, J. H.; Holmes, H. R.

    1991-01-01

    High-capacity heat pipe radiator panels have been proposed as the primary means of heat rejection for Space Station Freedom. In this system, the heat pipe would interface with the thermal bus condensers. Changes in system heat load can produce large temperature and heat load variations in individual heat pipes. Heat pipes could be required to start from an initially cold state, with heat loads temporarily exceeding their low-temperature transport capacity. The present research was motivated by the need for accurate prediction of such transient operating conditions. In this work, the cold startup of a 6.7-meter long high-capacity heat pipe is investigated experimentally and analytically. A transient thermohydraulic model of the heat pipe was developed which allows simulation of partially-primed operation. The results of cold startup tests using both constant temperature and constant heat flux evaporator boundary conditions are shown to be in good agreement with predicted transient response.

  2. Reassembling and testing of a high-precision heat capacity drop calorimeter. Heat capacity of some polyphenyls at T = 298.15 K

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Luis M.N.B.F., E-mail: lbsantos@fc.up.pt [Centro de Investigacao em Quimica, Departamento de Quimica e Bioquimica, Faculdade de Ciencias, Universidade do Porto, Rua do Campo Alegre, 687, 4169-007 Porto (Portugal); Rocha, Marisa A.A.; Rodrigues, Ana S.M.C. [Centro de Investigacao em Quimica, Departamento de Quimica e Bioquimica, Faculdade de Ciencias, Universidade do Porto, Rua do Campo Alegre, 687, 4169-007 Porto (Portugal); Stejfa, Vojtech; Fulem, Michal [Department of Physical Chemistry, Institute of Chemical Technology, Technicka 5, CZ-166 28 Prague 6 (Czech Republic); Bastos, Margarida [Centro de Investigacao em Quimica, Departamento de Quimica e Bioquimica, Faculdade de Ciencias, Universidade do Porto, Rua do Campo Alegre, 687, 4169-007 Porto (Portugal)

    2011-12-15

    Graphical abstract: Highlights: > We present the reassembling, improvement and testing of a high-precision C{sub p} drop calorimeter. > The apparatus was tested, using benzoic acid and hexafluorobenzene. > The high sensitivity of the apparatus is comparable to the one obtained in adiabatic calorimetry. > Heat capacities at T = 298.15 K of some polyphenyls were measured. > Subtle heat capacity differences among position isomers (ortho, meta, para) were detected. - Abstract: The description of the reassembling and testing of a twin heat conduction, high-precision, drop microcalorimeter for the measurement of heat capacities of small samples are presented. The apparatus, originally developed and used at the Thermochemistry Laboratory, Lund, Sweden, has now been reassembled and modernized, with changes being made as regarding temperature sensors, electronics and data acquisition system. The apparatus was thereafter thoroughly tested, using benzoic acid and hexafluorobenzene as test substances. The accuracy of the C{sub p,m}{sup 0} (298.15 K) data obtained with this apparatus is comparable to that achieved by high-precision adiabatic calorimetry. Here we also present the results of heat capacity measurements on of some polyphenyls (1,2,3-triphenylbenzene, 1,3,5-triphenylbenzene, p-terphenyl, m-terphenyl, o-terphenyl, p-quaterphenyl) at T = 298.15 K, measured with the renewed high precision heat capacity drop calorimeter system. The high resolution and accuracy of the obtained heat capacity data enabled differentiation among the ortho-, meta-, and para-phenyl isomers.

  3. Evaluation of Heat Capacity and Resistance to Cyclic Oxidation of Nickel Superalloys

    Directory of Open Access Journals (Sweden)

    Przeliorz R.

    2014-08-01

    Full Text Available Paper presents the results of evaluation of heat resistance and specific heat capacity of MAR-M-200, MAR-M-247 and Rene 80 nickel superalloys. Heat resistance was evaluated using cyclic method. Every cycle included heating in 1100°C for 23 hours and cooling for 1 hour in air. Microstructure of the scale was observed using electron microscope. Specific heat capacity was measured using DSC calorimeter. It was found that under conditions of cyclically changing temperature alloy MAR-M-247 exhibits highest heat resistance. Formed oxide scale is heterophasic mixture of alloying elements, under which an internal oxidation zone was present. MAR-M-200 alloy has higher specific heat capacity compared to MAR-M-247. For tested alloys in the temperature range from 550°C to 800°C precipitation processes (γ′, γ″ are probably occurring, resulting in a sudden increase in the observed heat capacity.

  4. Temperature fluctuation and heat capacity in relativistic heavy-ion collisions

    CERN Document Server

    Ma, Guo Liang; Chen Jin Gen; He Ze-Jun; Long Jia-Li; Lu Zhao-Hui; Ma Yu-Gang; Sá Ben-Hao; Shen Wen-Qing; Wang Kun; Wei Yi-Bin; Zhang Hu-Yong; Zhong Chen

    2004-01-01

    We used LUCIAE3.0 model to simulate the Pb+Pb and C+C in SPS energy. The heat capacity was then extracted from event-by-event temperature fluctuation. It is found that the heat capacity per hadron multiplicity decreases with the increasing of beam energy and impact parameter for a given reaction system. While the hadron mass increases, the heat capacity per hadron multiplicity rises. In addition, we found that, for a given hadron, the heat capacity per hadron multiplicity is almost the same regardless of the reaction system. Some discussions were also given.

  5. Decoding heat capacity features from the energy landscape

    Science.gov (United States)

    Wales, David J.

    2017-03-01

    A general scheme is derived to connect transitions in configuration space with features in the heat capacity. A formulation in terms of occupation probabilities for local minima that define the potential energy landscape provides a quantitative description of how contributions arise from competition between different states. The theory does not rely on a structural interpretation for the local minima, so it is equally applicable to molecular energy landscapes and the landscapes defined by abstract functions. Applications are presented for low-temperature solid-solid transitions in atomic clusters, which involve just a few local minima with different morphologies, and for cluster melting, which is driven by the landscape entropy associated with the more numerous high-energy minima. Analyzing these features in terms of the balance between states with increasing and decreasing occupation probabilities provides a direct interpretation of the underlying transitions. This approach enables us to identify a qualitatively different transition that is caused by a single local minimum associated with an exceptionally large catchment volume in configuration space for a machine learning landscape.

  6. Thermodynamics of micellization from heat-capacity measurements.

    Science.gov (United States)

    Šarac, Bojan; Bešter-Rogač, Marija; Lah, Jurij

    2014-06-23

    Differential scanning calorimetry (DSC), the most important technique for studying the thermodynamics of structural transitions of biological macromolecules, is seldom used in quantitative thermodynamic studies of surfactant micellization/demicellization. The reason for this could be ascribed to an insufficient understanding of the temperature dependence of the heat capacity of surfactant solutions (DSC data) in terms of thermodynamics, which leads to problems with the design of experiments and interpretation of the output signals. We address these issues by careful design of DSC experiments performed with solutions of ionic and nonionic surfactants at various surfactant concentrations, and individual and global mass-action model analysis of the obtained DSC data. Our approach leads to reliable thermodynamic parameters of micellization for all types of surfactants, comparable with those obtained by using isothermal titration calorimetry (ITC). In summary, we demonstrate that DSC can be successfully used as an independent method to obtain temperature-dependent thermodynamic parameters for micellization. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Temperature dependence of electronic heat capacity in Holstein model of DNA

    Science.gov (United States)

    Fialko, N.; Sobolev, E.; Lakhno, V.

    2016-04-01

    The dynamics of charge migration was modeled to calculate temperature dependencies of its thermodynamic equilibrium values such as energy and electronic heat capacity in homogeneous adenine fragments. The energy varies from nearly polaron one at T ∼ 0 to midpoint of the conductivity band at high temperatures. The peak on the graph of electronic heat capacity is observed at the polaron decay temperature.

  8. Saturated-liquid heat capacity of organic compounds: new empirical correlation model

    Directory of Open Access Journals (Sweden)

    DUSAN K. GROZDANIC

    2004-03-01

    Full Text Available A new saturated-liquid heat capacity model is recommended. This model is tested and compared with the known polynomial and quasi-polynomial models on 39 sets with 1453 experimental heat capacity data. The obtained results indicate that the new model is better then the existing models, especially near the critical point.

  9. Droplet Evaporator For High-Capacity Heat Transfer

    Science.gov (United States)

    Valenzuela, Javier A.

    1993-01-01

    Proposed heat-exchange scheme boosts heat transfer per unit area. Key component is generator that fires uniform size droplets of subcooled liquid at hot plate. On impact, droplets spread out and evaporate almost instantly, removing heat from plate. In practice, many generator nozzles arrayed over evaporator plate.

  10. Heat capacity for systems with excited-state quantum phase transitions

    Energy Technology Data Exchange (ETDEWEB)

    Cejnar, Pavel; Stránský, Pavel, E-mail: stransky@ipnp.troja.mff.cuni.cz

    2017-03-18

    Heat capacities of model systems with finite numbers of effective degrees of freedom are evaluated using canonical and microcanonical thermodynamics. Discrepancies between both approaches, which are observed even in the infinite-size limit, are particularly large in systems that exhibit an excited-state quantum phase transition. The corresponding irregularity of the spectrum generates a singularity in the microcanonical heat capacity and affects smoothly the canonical heat capacity. - Highlights: • Thermodynamics of systems with excited-state quantum phase transitions • ESQPT-generated singularities of the microcanonical heat capacity • Non-monotonous dependences of the canonical heat capacity • Discord between canonical and microcanonical pictures in the infinite-size limit.

  11. Characterization of Molten CZT Using Thermal Conductivity and Heat Capacity

    Energy Technology Data Exchange (ETDEWEB)

    Nero, Franco [Y-12 National Security Complex, Oak Ridge, TN (United States); Jackson, Maxx [Y-12 National Security Complex, Oak Ridge, TN (United States); Stowe, Ashley [Y-12 National Security Complex, Oak Ridge, TN (United States)

    2017-10-10

    To compare thermal conductivity of a polycrystalline semiconductor to the single crystal semiconductor using thermo-physical data acquired from Simultaneous Thermal Analysis and Transient Plane Source heating.

  12. Measurement and Model Validation of Nanofluid Specific Heat Capacity with Differential Scanning Calorimetry

    Directory of Open Access Journals (Sweden)

    Harry O'Hanley

    2012-01-01

    Full Text Available Nanofluids are being considered for heat transfer applications; therefore it is important to know their thermophysical properties accurately. In this paper we focused on nanofluid specific heat capacity. Currently, there exist two models to predict a nanofluid specific heat capacity as a function of nanoparticle concentration and material. Model I is a straight volume-weighted average; Model II is based on the assumption of thermal equilibrium between the particles and the surrounding fluid. These two models give significantly different predictions for a given system. Using differential scanning calorimetry (DSC, a robust experimental methodology for measuring the heat capacity of fluids, the specific heat capacities of water-based silica, alumina, and copper oxide nanofluids were measured. Nanoparticle concentrations were varied between 5 wt% and 50 wt%. Test results were found to be in excellent agreement with Model II, while the predictions of Model I deviated very significantly from the data. Therefore, Model II is recommended for nanofluids.

  13. Determination of the thermal conductivity and specific heat capacity of neem seeds by inverse problem method

    Directory of Open Access Journals (Sweden)

    S.N. Nnamchi

    2010-01-01

    Full Text Available Determination of the thermal conductivity and the specific heat capacity of neem seeds (Azadirachta indica A. Juss usingthe inverse method is the main subject of this work. One-dimensional formulation of heat conduction problem in a spherewas used. Finite difference method was adopted for the solution of the heat conduction problem. The thermal conductivityand the specific heat capacity were determined by least square method in conjunction with Levenberg-Marquardt algorithm.The results obtained compare favourably with those obtained experimentally. These results are useful in the analysis ofneem seeds drying and leaching processes.

  14. Magnetocaloric effect and the heat capacity of ferrimagnetic nanosystems in magnetic fluids

    Science.gov (United States)

    Korolev, V. V.; Aref'ev, I. M.; Ramazanova, A. G.

    2007-10-01

    The specific heat capacity of a magnetite-based magnetic fluid and changes in the magnetic part of the molar heat capacity of its magnetic phase in magnetic fields of 0 0.7 T were determined calorimetrically over the temperature range 288 353 K. The temperature dependence of changes in the magnetic part of entropy in an applied magnetic field was calculated. It was found that the field dependence of heat capacity had a maximum in fields of 0.3 0.4 T, and the temperature dependences of changes in the magnetic part of heat capacity Δ C p ( H) and entropy Δ S m( H) had maxima at the magnetic phase transition temperature.

  15. Study of heating capacity of focused IR light soldering systems.

    Science.gov (United States)

    Anguiano, C; Félix, M; Medel, A; Bravo, M; Salazar, D; Márquez, H

    2013-10-07

    An experimental study about four optical setups used for developing a Focused IR Light Soldering System (FILSS) for Surface Mount Technology (SMT) lead-free electronic devices specifically for Ball Grid Arrays (BGA) is presented. An analysis of irradiance and infrared thermography at BGA surface is presented, as well as heat transfer by radiation and conduction process from the surface of the BGA to the solder balls. The results of this work show that the heating provided by our proposed optical setups, measured at the BGA under soldering process, meets the high temperature and uniform thermal distribution requirements, which are defined by the reflow solder method for SMT devices.

  16. Solvation thermodynamics and heat capacity of polar and charged solutes in water.

    Science.gov (United States)

    Sedlmeier, Felix; Netz, Roland R

    2013-03-21

    The solvation thermodynamics and in particular the solvation heat capacity of polar and charged solutes in water is studied using atomistic molecular dynamics simulations. As ionic solutes we consider a F(-) and a Na(+) ion, as an example for a polar molecule with vanishing net charge we take a SPC/E water molecule. The partial charges of all three solutes are varied in a wide range by a scaling factor. Using a recently introduced method for the accurate determination of the solvation free energy of polar solutes, we determine the free energy, entropy, enthalpy, and heat capacity of the three different solutes as a function of temperature and partial solute charge. We find that the sum of the solvation heat capacities of the Na(+) and F(-) ions is negative, in agreement with experimental observations, but our results uncover a pronounced difference in the heat capacity between positively and negatively charged groups. While the solvation heat capacity ΔC(p) stays positive and even increases slightly upon charging the Na(+) ion, it decreases upon charging the F(-) ion and becomes negative beyond an ion charge of q = -0.3e. On the other hand, the heat capacity of the overall charge-neutral polar solute derived from a SPC/E water molecule is positive for all charge scaling factors considered by us. This means that the heat capacity of a wide class of polar solutes with vanishing net charge is positive. The common ascription of negative heat capacities to polar chemical groups might arise from the neglect of non-additive interaction effects between polar and apolar groups. The reason behind this non-additivity is suggested to be related to the second solvation shell that significantly affects the solvation thermodynamics and due to its large spatial extent induces quite long-ranged interactions between solvated molecular parts and groups.

  17. Calculation of heat capacities of light and heavy water by path-integral molecular dynamics.

    Science.gov (United States)

    Shiga, Motoyuki; Shinoda, Wataru

    2005-10-01

    As an application of atomistic simulation methods to heat capacities, path-integral molecular dynamics has been used to calculate the constant-volume heat capacities of light and heavy water in the gas, liquid, and solid phases. While the classical simulation based on conventional molecular dynamics has estimated the heat capacities too high, the quantum simulation based on path-integral molecular dynamics has given reasonable results based on the simple point-charge/flexible potential model. The calculated heat capacities (divided by the Boltzmann constant) in the quantum simulation are 3.1 in the vapor H2O at 300 K, 6.9 in the liquid H2O at 300 K, and 4.1 in the ice Ih H2O at 250 K, respectively, which are comparable to the experimental data of 3.04, 8.9, and 4.1, respectively. The quantum simulation also reproduces the isotope effect. The heat capacity in the liquid D2O has been calculated to be 10% higher than that of H2O, while it is 13% higher in the experiment. The results demonstrate that the path-integral simulation is a promising approach to quantitatively evaluate the heat capacities for molecular systems, taking account of quantum-mechanical vibrations as well as strongly anharmonic motions.

  18. Ambient heat capacities and entropies of ionic solids: a unique view using the Debye equation.

    Science.gov (United States)

    Glasser, Leslie

    2013-06-03

    Entropies of solids are obtained experimentally as integrals of measured heat capacities over the temperature range from zero to ambient. Correspondingly, the Debye phonon distribution equation for solids provides a theoretical connection between these two chemical thermodynamic measures. We examine how the widely applicable Debye equation illuminates the relation between the corresponding experimental measures using more than 250 ionic solids. Estimation of heat capacities for simple ionic solids by the Dulong-Petit heat capacity limit, by the Neumann-Kopp elemental sum, and by the ion sum method is examined in relation to the Debye equation. We note that, and explain why, the ambient temperature heat capacities and entropies of ionic solids are found to be approximately equal, and how deviations from equality may be related to the Debye temperature, ΘD, which characterizes the Debye equation. It is also demonstrated that Debye temperatures may be readily estimated from the experimental ratio of ambient heat capacity to entropy, C(p)/S(p), rather than requiring resort to elaborate theoretical or experimental procedures for their determination. Correspondingly, ambient mineral entropies and heat capacities are linearly correlated and may thus be readily estimated from one another.

  19. Effect of Inhomogeneous Heat Flow on the Enhancement of Heat Capacity in Helium-II by Counterflow near Tλ

    Science.gov (United States)

    Boyd, S. T. P.; Chatto, A. R.; Lee, R. A. M.; Duncan, R. V.; Goodstein, D. L.

    2006-09-01

    In 2000 Harter et al. reported the first measurements of the enhancement of the heat capacity ΔCQ≡C(Q)-C(Q=0) of helium-II transporting a heat flux density Q near Tλ. Surprisingly, their measured ΔCQ was ˜7-12 times larger than predicted, depending on which theory was assumed. In this report we present a candidate explanation for this discrepancy: unintended heat flux inhomogeneity. Because C(Q) should diverge at a critical heat flux density Qc, homogeneous heat flow is required for an accurate measurement. We present results from numerical analysis of the heat flow in the Harter et al. cell indicating that substantial inhomogeneity occurred. We determine the effect of the inhomogeneity on ΔCQ and find rough agreement with the observed disparity between prediction and measurement.

  20. Determination of Specific Heat Capacity on Composite Shape-Stabilized Phase Change Materials and Asphalt Mixtures by Heat Exchange System.

    Science.gov (United States)

    Ma, Biao; Zhou, Xue-Yan; Liu, Jiang; You, Zhanping; Wei, Kun; Huang, Xiao-Feng

    2016-05-19

    Previous research has shown that composite shape-stabilized phase change material (CPCM) has a remarkable capacity for thermal storage and stabilization, and it can be directly applied to highway construction without leakage. However, recent studies on temperature changing behaviors of CPCM and asphalt mixture cannot intuitively reflect the thermoregulation mechanism and efficiency of CPCM on asphalt mixture. The objective of this paper is to determine the specific heat capacity of CPCM and asphalt mixtures mixed with CPCM using the heat exchange system and the data acquisition system. Studies have shown that the temperature-rise curve of 5 °C CPCM has an obvious temperature plateau, while an asphalt mixture mixed with 5 °C CPCM does not; with increasing temperature, the specific heat capacities of both 5 °C CPCM and asphalt mixture first increase and then decrease, while the variation rate of 5 °C CPCM is larger than that of the asphalt mixture, and the maximum specific heat capacity of 5 °C CPCM appears around the initial phase change temperature. It is concluded that the temperature intervals of 5 °C CPCM are -18 °C-7 °C, 7 °C-25 °C and 25 °C-44 °C, respectively, and that of the asphalt mixture are -18 °C~10 °C, -10 °C~5 °C and 5 °C~28 °C. A low dosage of 5 °C CPCM has little influence on the specific heat capacity of asphalt mixture. Finally, the functions of specific heat capacities and temperature for CPCM and asphalt mixture mixed with CPCM were recommended by the sectional regression method.

  1. A New Method for the Determination of the Specific Heat Capacity Using Laser-Flash Calorimetry Down to 77K

    Science.gov (United States)

    Göbel, A.; Hemberger, F.; Vidi, S.; Ebert, H.-P.

    2013-05-01

    A new method for evaluation of the specific heat capacity in the temperature regime between 77K and 330K using laser-flash calorimetry is presented. Usually, laser-flash calorimetry is accomplished by performing an additional laser-flash measurement on a reference specimen with a known specific heat capacity and by comparing the maximum rear-side temperatures rises. In this study, the calibration is achieved by comparison of the rear-side temperature rise to specific-heat-capacity data determined by other methods in an adjacent temperature regime. Subsequently, the thus yielded proportional factor is used for the evaluation of the specific heat capacity from laser-flash measurements at temperatures where no specific-heat-capacity data are available. The reliability of this method is shown by performing measurements on a material with known specific heat capacity, aluminum oxide. Furthermore, the specific heat capacity and thermal conductivity of borosilicate crown glass (BK7) was determined experimentally.

  2. Influence of collector heat capacity and internal conditions of heat exchanger on cool-down process of small gas liquefier

    Science.gov (United States)

    Saberimoghaddam, Ali; Bahri Rasht Abadi, Mohammad Mahdi

    2018-01-01

    Joule-Thomson cooling systems are commonly used in gas liquefaction. In small gas liquefiers, transient cool-down time is high. Selecting suitable conditions for cooling down process leads to decrease in time and cost. In the present work, transient thermal behavior of Joule-Thomson cooling system including counter current helically coiled tube in tube heat exchanger, expansion valve, and collector was studied using experimental tests and simulations. The experiments were performed using small gas liquefier and nitrogen gas as working fluid. The heat exchanger was thermally studied by experimental data obtained from a small gas liquefier. In addition, the simulations were performed using experimental data as variable boundary conditions. A comparison was done between presented and conventional methods. The effect of collector heat capacity and convection heat transfer coefficient inside the tubes on system performance was studied using temperature profiles along the heat exchanger.

  3. Measurements of thermal diffusivity, specific heat capacity and thermal conductivity with LFA 447 apparatus

    DEFF Research Database (Denmark)

    Zajas, Jan Jakub; Heiselberg, Per

    The LFA 447 can be successfully used for measurements of thermal diffusivity, specific heat and thermal conductivity of various samples. It is especially useful when determining the properties of materials on a very small scale. The matrix measurement mode allows for determining the local...... properties with a fine resolution, down to 1 millimeter. Special attention needs to be taken when determining the specific heat capacity in the comparative method. First of all, the test and reference sample should be of nearly identical thickness. Secondly, their heat diffusion time should be comparable, so...... that the heat losses from both samples during the measurement are similar. Finally, the leveling of the samples is very important. Very small discrepancies can cause a massive error in the derivation of specific heat capacity and, as a result, thermal conductivity....

  4. Cooling and Heating Season Impacts of Right-Sizing of Fixed- and Variable-Capacity Heat Pumps With Attic and Indoor Ductwork

    Energy Technology Data Exchange (ETDEWEB)

    Cummings, James [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States); Withers, Charles [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States); Kono, Jamie [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States)

    2015-06-01

    A new generation of central, ducted variable-capacity heat pump systems has come on the market, promising very high cooling and heating efficiency. They are controlled differently than standard fixed-capacity systems. Instead of cycling on at full capacity and then cycling off when the thermostat is satisfied, they vary their cooling and heating output over a wide range (approximately 40% - 118% of nominal full capacity), thus staying 'on' for 60% - 100% more hours per day compared to fixed -capacity systems. Experiments in this research examined the performance of 2-ton and 3-ton fixed- and variable-capacity systems and the impacts of system oversizing.

  5. Technical-and-Economic Efficiency of Draft Enriched with Oxygen in Small-Capacity Heating Boilers

    Directory of Open Access Journals (Sweden)

    P. Ratnikov

    2013-01-01

    Full Text Available Data on complex experimental and theoretical investigations pertaining to efficiency of oxygen-enriched draft in the small-capacity heating boilers as exemplified by the plant HEIZA (HW-S-10/K have been presented in the paper. The paper provides a calculation model of heating processes in heat generator burner (as exemplified by HEIZA plant. Simulation of heating processes in the operational zone has been executed in paper. The experimental data have proved model adequacy. The calculation scheme of the plant will be used in future for determination of power and ecological efficiency of draft enrichment with oxygen.

  6. Heat Capacity, Crystallization, and Nucleation in Poly(vinyl alcohol) Thin Films

    Science.gov (United States)

    Thomas, David; Wurm, Andreas; Zhuravlev, Evgeny; Schick, Christoph; Cebe, Peggy

    Polyvinyl alcohol (PVA) is hydrophilic, biodegradable, semi-crystalline polymer with a wide array of applications ranging from textiles and packaging to medicine. Despite possessing favorable properties, PVA thermally degrades at temperatures just in excess of 200 °C which occurs slightly below the observed peak endothermic melting peak at 203 °C. Utilizing fast scanning calorimetry it is possible to minimize sample degradation allowing measurements of the liquid phase heat capacity as well as study nucleation and crystallization from the amorphous melt state. Samples cut from parent films 2-3 μm thick were placed on UFSC1 sensors and brought between -80 and 270 °C at rates of 2000 °C/s under a nitrogen atmosphere. After five complete cycles samples did not show any signs of degradation. By fitting the symmetry corrected glassy phase heat capacity with literature values for the specific heat capacity from the ATHAS databank sample masses were determined to vary between 15-50 ng. Homogeneous nucleation was observed for all samples cooled from the melt with peak temperature 123 °C. Fitting linear heat capacity baselines in the melt and glassy states it was possible to obtain an experimental measurement of the heat capacity increment 44.5 J/mol K at the glass transition 85 °C. NSF DMR-1206010.

  7. A Framework for Spatial Assessment of Local Level Vulnerability and Adaptive Capacity to Extreme Heat

    Science.gov (United States)

    Wilhelmi, O.; Hayden, M.; Harlan, S.; Ruddell, D.; Komatsu, K.; England, B.; Uejio, C.

    2008-12-01

    Changing climate is predicted to increase the intensity and impacts of heat waves prompting the need to develop preparedness and adaptation strategies that reduce societal vulnerability. Central to understanding societal vulnerability, is adaptive capacity, the potential of a system or population to modify its features/behaviors so as to better cope with existing and anticipated stresses and fluctuations. Adaptive capacity influences adaptation, the actual adjustments made to cope with the impacts from current and future hazardous heat events. Understanding societal risks, vulnerabilities and adaptive capacity to extreme heat events and climate change requires an interdisciplinary approach that includes information about weather and climate, the natural and built environment, social processes and characteristics, interactions with the stakeholders, and an assessment of community vulnerability. This project presents a framework for an interdisciplinary approach and a case study that explore linkages between quantitative and qualitative data for a more comprehensive understanding of local level vulnerability and adaptive capacity to extreme heat events in Phoenix, Arizona. In this talk, we will present a methodological framework for conducting collaborative research on societal vulnerability and adaptive capacity on a local level that includes integration of household surveys into a quantitative spatial assessment of societal vulnerability. We highlight a collaborative partnership among researchers, community leaders and public health officials. Linkages between assessment of local adaptive capacity and development of regional climate change adaptation strategies will be discussed.

  8. Heat capacities and asymmetric criticality of coexistence curves for benzonitrile + alkanes and dimethyl carbonate + alkanes.

    Science.gov (United States)

    Huang, Meijun; Lei, Yuntao; Yin, Tianxiang; Chen, Zhiyun; An, Xueqin; Shen, Weiguo

    2011-11-24

    The critical behavior of isobaric heat capacities per unit volume for a series of critical binary solutions {benzonitrile + octane, or dodecane, or hexadecane} and {dimethyl carbonate + nonane, or decane, or dodecane} were studied. The corresponding exponent was obtained to be in consistent with the 3D-Ising value. The amplitudes in one-phase and two-phase regions were deduced, which were used to test some critical amplitude ratios. Analysis of the dependence of the effective critical exponent of the heat capacity on the temperature indicated a critical crossover from the 3D-Ising to the mean-field for all the studied systems. It was found that the heat capacity does play an important role for describing the asymmetric criticality of coexistence curves by the complete scaling theory. © 2011 American Chemical Society

  9. The Magnetocaloric Effect and Heat Capacity of Suspensions of High-Dispersity Samarium Ferrite

    Science.gov (United States)

    Korolev, V. V.; Aref'ev, I. M.; Ramazanova, A. G.

    2008-02-01

    The magnetocaloric effect and specific heat capacity of an aqueous suspension of samarium ferrite were determined calorimetrically over the temperature range 288-343 K in magnetic fields of 0-0.7 T. The data obtained were used to calculate changes in the magnetic component of the molar heat capacity and entropy of the magnetic phase and changes in the enthalpy of the process under an applied magnetic field. The magnetocaloric effect was found to increase nonlinearly as the magnetic field induction grew. The corresponding temperature dependences contained a maximum at 313 K related to the second-order magnetic phase transition at the Curie point. The field and temperature dependences of heat capacity contained a maximum in fields of 0.4 T and a minimum at the magnetic phase transition temperature.

  10. Excess enthalpy, density, and heat capacity for binary systems of alkylimidazolium-based ionic liquids + water

    Energy Technology Data Exchange (ETDEWEB)

    Garcia-Miaja, Gonzalo; Troncoso, Jacobo [Departamento de Fisica Aplicada, Universidad de Vigo, Facultad de Ciencias, Campus As Lagoas, 32004 Ourense (Spain); Romani, Luis [Departamento de Fisica Aplicada, Universidad de Vigo, Facultad de Ciencias, Campus As Lagoas, 32004 Ourense (Spain)], E-mail: romani@uvigo.es

    2009-02-15

    Experimental measurements of excess molar enthalpy, density, and isobaric molar heat capacity are presented for a set of binary systems ionic liquid + water as a function of temperature at atmospheric pressure. The studied ionic liquids are 1-butyl-3-methylpyridinium tetrafluoroborate, 1-ethyl-3-methylimidazolium ethylsulfate, 1-butyl-3-methylimidazolium methylsulfate, 1-butyl-3-methylimidazolium trifluoromethanesulfonate, and 1-ethyl-3-methylimidazolium trifluoromethanesulfonate. Excess molar enthalpy was measured at 303.15 K whereas density and heat capacity were determined within the temperature range (293.15 to 318.15) K. From experimental data, excess molar volume and excess molar isobaric heat capacity were calculated. The analysis of the excess properties reveals important differences between the studied ionic liquids which can be ascribed to their capability to form hydrogen bonds with water molecules.

  11. THERMAL STUDY OF THE DIII-D MACHINE HEAT REMOVAL CAPACITY

    Energy Technology Data Exchange (ETDEWEB)

    YIP,H; ADERSON,P.M; HOLTROP,K.L; HARRISON,S

    2003-10-01

    OAK-B135 With each plasma shot, the DIII-D tokamak dissipates 0.5 to 1.0 GJ of energy. Plasma shots may occur as frequently as every ten minutes, and the energy is removed in the form of heat by a cooling water system. to remove heat from the machine, cooling water circulates through each major heat source. These sources include the power supplies, motor/generator, rf current drives, neutral beam power supplies, magnetic field coils, and vacuum vessel. The cooling water system consists of isolated primary and secondary cooling loops separated by intermediate heat exchangers. As future DIII-D plans include operation during summer months and longer pulse duration, the cooling system's overall heat removal capability and performance efficiency must be assessed. Temperature and flow data from around the DIII-D facility are collected by a programmable logic controller (PLC); the data are used to analyze the heat generating sources, the heat transfer rate to intermediate heat exchangers, and the ultimate heat rejection to the environment via the cooling towers. A comparison of the original DIII-D machine design versus the actual performance determines the margin of heat removal capacity. projections of the heat removal rate for various longer plasma shots are made. Improvements in design and/or operational procedure will be necessary to attain the desired pulse duration.

  12. Heat Capacity Uncertainty Calculation for the Eutectic Mixture of Biphenyl/Diphenyl Ether Used as Heat Transfer Fluid: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Gomez, J. C.; Glatzmaier, G. C.; Mehos, M.

    2012-09-01

    The main objective of this study was to calculate the uncertainty at 95% confidence for the experimental values of heat capacity of the eutectic mixture of biphenyl/diphenyl ether (Therminol VP-1) determined from 300 to 370 degrees C. Twenty-five samples were evaluated using differential scanning calorimetry (DSC) to obtain the sample heat flow as a function of temperature. The ASTM E-1269-05 standard was used to determine the heat capacity using DSC evaluations. High-pressure crucibles were employed to contain the sample in the liquid state without vaporizing. Sample handling has a significant impact on the random uncertainty. It was determined that the fluid is difficult to handle, and a high variability of the data was produced. The heat capacity of Therminol VP-1 between 300 and 370 degrees C was measured to be equal to 0.0025T+0.8672 with an uncertainty of +/- 0.074 J/g.K (3.09%) at 95% confidence with T (temperature) in Kelvin.

  13. Investigations of temperature dependences of electrical resistivity and specific heat capacity of metals

    Energy Technology Data Exchange (ETDEWEB)

    Eser, Erhan, E-mail: eserphy@gmail.com [Department of Physics, Polatlı Faculty of Arts and Sciences, Gazi University, Polatlı, Ankara (Turkey); Koç, Hüseyin [Department of Electrical and Electronics Engineering, Faculty of Engineering, Muş Alparslan University, Muş (Turkey)

    2016-07-01

    In this study, we calculated the electrical resistivity and heat capacities of some ideal metals (Cu, Pt, and Pd) using a method that it employs the statistical model and Debye functions. The method is used to provide a simple and reliable analytical procedure for wide temperature range. The results obtained for the electrical resistivity and heat capacity have been compared with the results in literature. The results obtained at low temperature are in excellent agreement with experimental and theoretical results. Finally the used approximation and analytical method are a useful approach to calculate thermophysical properties of metals.

  14. High-temperature heat capacity of CdO-V2O5 oxides

    Science.gov (United States)

    Denisova, L. T.; Chumilina, L. G.; Belousova, N. V.; Denisov, V. M.; Galiakhmetova, N. A.

    2017-12-01

    Vanadates Cd2V2O7 and CdV2O6 have been prepared from CdO i V2O5 by three-phase synthesis with subsequent burning at 823-1073 K and 823-853 K, respectively. The molar heat capacity of these oxide compounds has been measured by differential scanning calorimetry. The enthalpy change, the entropy change, and the reduced Gibbs energy are calculated using the experimental dependences C p = f( T). It is shown that there is a correlation between the specific heat capacity and the composition of CdO-V2O5 oxide system.

  15. Molecular mobility, thermodynamics and stability of griseofulvin's ultraviscous and glassy states from dynamic heat capacity.

    Science.gov (United States)

    Tombari, E; Presto, S; Johari, G P; Shanker, Ravi M

    2008-04-01

    To determine the calorimetric relaxation time needed for modeling griseofulvin's stability against crystallization during storage. Both temperature-modulated and unmodulated scanning calorimetry have been used to determine the heat capacity of griseofulvin in the glassy and melt state. The calorimetric relaxation time, tau cal, of its melt varies with the temperature T according to the relation, tau cal [s] = 10(-13.3) exp [2, 292 /(T[K] - 289.5)] , and the distribution of relaxation times parameter is 0.67. The unrelaxed heat capacity of the griseofulvin melt is equal to its vibrational heat capacity. Griseofulvin neither crystallizes on heating to 373 K at 1 K/h rate, nor on cooling. Molecular mobility and vibrational heat capacity measured here are more reliable for modeling a pharmaceutical's stability against crystallization than the currently used kinetics-thermodynamics relations, and molecular mobility in the (fixed structure) glassy state is much greater than the usual extrapolation from the melt state yields. Molecular relaxation time of the glassy state of griseofulvin is about 2 months at 298 K, and longer at lower temperatures. It would spontaneously increase with time. If the long-range motions alone were needed for crystallization, griseofulvin would become more stable against crystallization during storage.

  16. Heat capacities and thermal diffusivities of n-alkane acid ethyl esters—biodiesel fuel components

    Science.gov (United States)

    Bogatishcheva, N. S.; Faizullin, M. Z.; Nikitin, E. D.

    2017-09-01

    The heat capacities and thermal diffusivities of ethyl esters of liquid n-alkane acids C n H2 n-1O2C2H5 with the number of carbon atoms in the parent acid n = 10, 11, 12, 14, and 16 are measured. The heat capacities are measured using a DSC 204 F1 Phoenix heat flux differential scanning calorimeter (Netzsch, Germany) in the temperature range of 305-375 K. Thermal diffusivities are measured by means of laser flash method on an LFA-457 instrument (Netzsch, Germany) at temperatures of 305-400 K. An equation is derived for the dependence of the molar heat capacities of the investigated esters on temperature. It is shown that the dependence of molar heat capacity C p,m (298.15 K) on n ( n = 1-6) is close to linear. The dependence of thermal diffusivity on temperature in the investigated temperature range is described by a first-degree polynomial, but thermal diffusivity a (298.15 K) as a function of n has a minimum at n = 5.

  17. Influence of heat treatment on antioxidant capacity and (poly)phenolic compounds of selected vegetables

    OpenAIRE

    Juaniz, I. (Isabel); Ludwig, I.A. (Iziar A.); Huarte, E; Pereira-Caro, G.; Moreno-Rojas, J.M.; Cid, C. (Concepción); Peña, M.P. (María Paz) de

    2016-01-01

    The impact of cooking heat treatments (frying in olive oil, frying in sunflower oil and griddled) on the antioxidant capacity and (poly)phenolic compounds of onion, green pepper and cardoon, was evaluated. The main compounds were quercetin and isorhamnetin derivates in onion, quercetin and luteolin derivates in green pepper samples, and chlorogenic acids in cardoon. All heat treatments tended to increase the concentration of phenolic compounds in vegetables suggesting a thermal destruction of...

  18. Parametric Study on the Dynamic Heat Storage Capacity of Building Elements

    DEFF Research Database (Denmark)

    Artmann, Nikolai; Manz, H.; Heiselberg, Per

    2007-01-01

    of onedimensional heat conduction in a slab with convective boundary condition was applied to quantify the dynamic heat storage capacity of a particular building element. The impact of different parameters, such as slab thickness, material properties and the heat transfer coefficient was investigated, as well......In modern, extensively glazed office buildings, due to high solar and internal loads and increased comfort expectations, air conditioning systems are often used even in moderate and cold climates. Particularly in this case, passive cooling by night-time ventilation seems to offer considerable...... potential. However, because heat gains and night ventilation periods do not coincide in time, a sufficient amount of thermal mass is needed in the building to store the heat. Assuming a 24 h-period harmonic oscillation of the indoor air temperature within a range of thermal comfort, the analytical solution...

  19. Building America Case Study: Impact of Improved Duct Insulation on Fixed-Capacity (SEER 13) and Variable-Capacity (SEER 22) Heat Pumps, Cocoa, Florida

    Energy Technology Data Exchange (ETDEWEB)

    C. Withers, J. Cummings, B. Nigusse, E. Martin

    2017-04-01

    A new generation of central, ducted variable-capacity heat pump systems has come on the market, promising very high cooling and heating efficiency. Instead of cycling on at full capacity and then cycling off when the thermostat is satisfied, they vary their cooling and heating output over a wide range (approximately 40 to 118% of nominal full capacity); thus, staying 'on' for 60% to 100% more hours per day compared to fixed-capacity systems. Current Phase 4 experiments in an instrumented lab home with simulated occupancy evaluate the impact of duct R-value enhancement on the overall operating efficiency of the variable-capacity system compared to the fixed-capacity system.

  20. Liquid heat capacity of the solvent system (piperazine + 2-amino-2-methyl-l-propanol + water)

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Y.-R. [R and D Center for Membrane Technology and Department of Chemical Engineering, Chung Yuan Christian University, Chung Li 32023, Taiwan (China); Caparanga, Alvin R.; Soriano, Allan N. [R and D Center for Membrane Technology and Department of Chemical Engineering, Chung Yuan Christian University, Chung Li 32023, Taiwan (China); School of Chemical Engineering and Chemistry, Mapua Institute of Technology, Intramuros, Manila 1002 (Philippines); Li, M.-H., E-mail: mhli@cycu.edu.t [R and D Center for Membrane Technology and Department of Chemical Engineering, Chung Yuan Christian University, Chung Li 32023, Taiwan (China)

    2010-04-15

    This report presents a new set of heat capacity data for the system piperazine left brace(PZ) + 2-amino-2-methyl-1-propanol (AMP) + water (H{sub 2}O)right brace, measured using the differential scanning calorimetry technique, over the temperature range 303.2 K to 353.2 K and at fourteen (14) different concentrations in which the water mole fractions, x{sub 3}'s, were fixed at 0.60, 0.70, 0.80, and 0.90. Heat capacity for the binary system left bracePZ (1) + AMP (2)right brace at x{sub 1} = 0.05, 0.10, 0.15, and 0.20 were, likewise, measured to generate parameters necessary in the Redlich-Kister-type model, which was used to estimate excess molar heat capacities. Such estimates were then used to predict the values of the molar heat capacity at the corresponding sets of temperature and concentration. The predicted values were subsequently compared against the measured values and the results are satisfactory.

  1. THE HEAT CAPACITY OF FLUORINATED PROPANE AND BUTANE DERIVATIVES BY DIFFERENTIAL SCANNING CALORIMETRY

    Science.gov (United States)

    The paper gives results of the measurement (to 3% accuracy) of the constant-pressure liquid-phase heat capacities of 21 hydrogen-containing fluorinated propane and butane derivatives and one fluorinated ether (CF3OCF2H) with boiling points ranging from -34.6 to 76.7 C, using diff...

  2. Modeling the Heat Capacity of Spider Silk Inspired Di-block Copolymers

    Science.gov (United States)

    Huang, W.; Krishnaji, S.; Kaplan, D.; Cebe, P.

    2011-03-01

    We synthesized and characterized a new family of di-block copolymers based on the amino acid sequences of Nephila clavipes major ampulate dragline spider silk, having the form HABn and HBAn (n=1-6), comprising an alanine-rich hydrophobic block, A, a glycine-rich hydrophilic block, B, and a histidine tag, H. Using temperature modulated differential scanning calorimetry (TMDSC), we captured the effect of bound water acting as a plasticizer for copolymer films which had been cast from water solution and dried. We determined the water content by thermogravimetry and used the weight loss vs. temperature to correct the mass in TMDSC experiments. Our result shows that non-freezing bound water has a strong plasticization effect which lowers the onset of the glass transition by about 10circ; C. The reversing heat capacities, Cp(T), for temperatures below and above the glass transition were also characterized by TMDSC. We then calculated the solid state heat capacities of our novel block copolymers below the glass transition (Tg) based on the vibrational motions of the constituent poly(amino acid)s, whose heat capacities are known from the ATHAS Data Bank. Excellent agreement was found between the measured and calculated values of the heat capacity, showing that this model can serve as a standard method to predict the solid state Cp for other biologically inspired block copolymers. Support was provided from the NSF CBET-0828028 and the MRI Program under DMR-0520655 for thermal analysis instrumentation.

  3. Glass heat capacity and its abrupt change in glass transition region

    DEFF Research Database (Denmark)

    Yue, Yuanzheng; Smedskjær, Morten Mattrup; Mauro, John C.

    Glass transition (GT) has been a fascinating, but challenging subject in the condensed matter science over decades. Despite progress in understanding GT, many crucial problems still need to be clarified. One of the problems deals with the microscopic origin of abrupt change of heat capacity (Cp) ...

  4. Low-temperature heat capacity and thermodynamic functions of vitamin B{sub 12}

    Energy Technology Data Exchange (ETDEWEB)

    Knyazev, A.V., E-mail: knyazevav@gmail.com; Smirnova, N.N.; Plesovskikh, A.S.; Shushunov, A.N.; Knyazeva, S.S.

    2014-04-01

    Graphical abstract: - Highlights: • Temperature dependence of heat capacity of vitamin B{sub 12} has been measured by precision adiabatic vacuum calorimetry. • The thermodynamic functions of the vitamin B{sub 12} have been determined for the range from T → 0 to 343 K. • The character of heterodynamics of structure was detected. • The thermal stability of cyanocobalamin was studied by differential scanning calorimetry. - Abstract: In the present work temperature dependence of heat capacity of vitamin B{sub 12} (cyanocobalamin) has been measured for the first time in the range from 6 to 343 K by precision adiabatic vacuum calorimetry. Based on the experimental data, the thermodynamic functions of the vitamin B{sub 12}, namely, the heat capacity, enthalpy H°(T) − H°(0), entropy S°(T) − S°(0) and Gibbs function G°(T) − H°(0) have been determined for the range from T → 0 to 343 K. The value of the fractal dimension D in the function of multifractal generalization of Debye's theory of the heat capacity of solids was estimated and the character of heterodynamics of structure was detected. The thermal stability of cyanocobalamin was also studied by differential scanning calorimetry.

  5. Comparative analysis of single- and continuously variable-capacity heat pump concepts

    Energy Technology Data Exchange (ETDEWEB)

    Rice, C.K.; Fischer, S.K.

    1984-01-01

    This work is an initial assessment of the potential benefits of continuous-capacity-modulation in electric-driven, air-to-air heat pumps for residential application. The purpose of the project was to provide a quantitative estimate of the possible annual performance gains of advanced continuously modulating heat pumps relative to single-speed designs at comparable levels of development. Previous analytical design work in this area at ORNL dealt with single-design-point, heating-mode optimization of single-speed heat pumps. For that work the ORNL Steady State Heat Pump Design Model was connected to a constrained numerical optimization code. The present work represents an extension of the earlier work in two directions. First, seasonal (heating and cooling) and annual performance factor (APF) analysis capability was added to allow direct evaluation of annual energy use from heat pump performance data generated by the ORNL heat pump model. Secondly, a modulating version of the heat pump model was developed to provide a means for simulating the steady state performance of continuously variable-speed (CVS) systems. With these tools, the APFs of both single- and continuously variable-capacity (CVC) concepts could be studied as basic heat pump design variables were varied. Based on this initial evaluation of CVS systems and considering the potential for electronics costs to further decrease as electricity prices rise, we see such advanced CVS systems as a strong future competitor to single-speed systems and as decidedly superior in energy conservation potential. To achieve this position, it seems especially important that such systems be computer optimized to take full advantage of the increased design flexibility available. Further, development of PM-ECMs or equivalent technology must continue to the point of providing speed controllers of: moderate to low cost, moderate to high performance, and high reliability. 16 refs., 12 figs.

  6. Enhancing heat capacity of colloidal suspension using nanoscale encapsulated phase-change materials for heat transfer.

    Science.gov (United States)

    Hong, Yan; Ding, Shujiang; Wu, Wei; Hu, Jianjun; Voevodin, Andrey A; Gschwender, Lois; Snyder, Ed; Chow, Louis; Su, Ming

    2010-06-01

    This paper describes a new method to enhance the heat-transfer property of a single-phase liquid by adding encapsulated phase-change nanoparticles (nano-PCMs), which absorb thermal energy during solid-liquid phase changes. Silica-encapsulated indium nanoparticles and polymer-encapsulated paraffin (wax) nanoparticles have been made using colloid method, and suspended into poly-alpha-olefin (PAO) and water for potential high- and low-temperature applications, respectively. The shells prevent leakage and agglomeration of molten phase-change materials, and enhance the dielectric properties of indium nanoparticles. The heat-transfer coefficients of PAO containing indium nanoparticles (30% by mass) and water containing paraffin nanoparticles (10% by mass) are 1.6 and 1.75 times higher than those of corresponding single-phase fluids. The structural integrity of encapsulation allows repeated use of such nanoparticles for many cycles in high heat generating devices.

  7. Thermodynamic functions of ZrW2O8 from its heat capacity

    Science.gov (United States)

    Ji, FengMin; Dai, XianXi; Stevens, R.; Goates, J. B.

    2012-04-01

    It is interesting to maximize the amount of information we can obtain from one experiment on a single sample. In obtaining all the thermodynamic properties of some materials from their experimental heat capacity data only, we aim to get the temperature- independent energy spectrum. However, all the practical measured energy spectra depend on the temperature of experiments. One promising method to obtain the temperature-independent energy spectrum is to solve the so-called specific heat-phonon spectrum inversion (SPI) problem. Here we show, by developing a new practical solution method of SPI, the phonon spectrum of the negative thermal expansion material ZrW2O8 is obtained. This phonon spectrum is temperature- independent and almost method independent. Hence all the thermodynamic properties of ZrW2O8, such as thermodynamic potential, entropy, Helmholtz free energy, etc. are obtained by heat capacity only.

  8. Final Report: Cooling Seasonal Energy and Peak Demand Impacts of Improved Duct Insulation on Fixed-Capacity (SEER 13) and Variable-Capacity (SEER 22) Heat Pumps

    Energy Technology Data Exchange (ETDEWEB)

    Withers, C. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States); Florida Solar Energy Center (FSEC), Cocoa, FL (United States); Cummings, J. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States); Florida Solar Energy Center (FSEC), Cocoa, FL (United States); Nigusse, B. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States); Florida Solar Energy Center (FSEC), Cocoa, FL (United States)

    2016-09-01

    A new generation of full variable-capacity, central, ducted air-conditioning (AC) and heat pump units has come on the market, and they promise to deliver increased cooling (and heating) efficiency. They are controlled differently than standard single-capacity (fixed-capacity) systems. Instead of cycling on at full capacity and then cycling off when the thermostat is satisfied, they can vary their capacity over a wide range (approximately 40% to 118% of nominal full capacity), thus staying “on” for up to twice as many hours per day compared to fixed-capacity systems of the same nominal capacity. The heating and cooling capacity is varied by adjusting the indoor fan air flow rate, compressor, and refrigerant flow rate as well as the outdoor unit fan air flow rate. Note that two-stage AC or heat pump systems were not evaluated in this research effort. The term dwell is used to refer to the amount of time distributed air spends inside ductwork during space-conditioning cycles. Longer run times mean greater dwell time and therefore greater exposure to conductive gains and losses.

  9. Final Report: Cooling Seasonal Energy and Peak Demand Impacts of Improved Duct Insulation on Fixed-Capacity (SEER 13) and Variable-Capacity (SEER 22) Heat Pumps

    Energy Technology Data Exchange (ETDEWEB)

    Withers, C. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States); Florida Solar Energy Center, Cocoa, FL (United States); Cummings, J. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States); Florida Solar Energy Center, Cocoa, FL (United States); Nigusse, B. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States); Florida Solar Energy Center, Cocoa, FL (United States)

    2016-09-08

    A new generation of full variable-capacity, central, ducted air-conditioning (AC) and heat pump units has come on the market, and they promise to deliver increased cooling (and heating) efficiency. They are controlled differently than standard single-capacity (fixed-capacity) systems. Instead of cycling on at full capacity and then cycling off when the thermostat is satisfied, they can vary their capacity over a wide range (approximately 40% to 118% of nominal full capacity), thus staying “on” for up to twice as many hours per day compared to fixed-capacity systems of the same nominal capacity. The heating and cooling capacity is varied by adjusting the indoor fan air flow rate, compressor, and refrigerant flow rate as well as the outdoor unit fan air flow rate. Note that two-stage AC or heat pump systems were not evaluated in this research effort. The term dwell is used to refer to the amount of time distributed air spends inside ductwork during space-conditioning cycles. Longer run times mean greater dwell time and therefore greater exposure to conductive gains and losses.

  10. Prediction of heat capacities and heats of vaporization of organic liquids by group contribution methods

    DEFF Research Database (Denmark)

    Ceriani, Roberta; Gani, Rafiqul; Meirelles, A.J.A.

    2009-01-01

    for 86 types of substances) included fatty compounds, such as fatty acids, esters, alcohols and triacylglycerols, and hydrocarbons. The performance of this method is compared with other published group contribution methods [Z. Kolska, J. Kukal, M. Zabransky, V. Ruzicka Ind. Eng. Chem. Res. 47 (2008) 2075......-2085] and the Rowlinson-Bondi equation. Also, the predictive performance of general correlations of heats of vaporization based on the corresponding-states method, such as Carruth and Kobayashi [G.F. Carruth, R. Kobayashi, Ind. Eng. Chem. Fundam. 11 (1972) 509-516], Sivaraman et al. [A. Sivaraman, J.W. Magee, R...... in the prediction of heats of vaporization of fatty compounds based on the vapor pressure model of Ceriani and Meirelles [R. Ceriani. A.J.A. Meirelles, Fluid Phase Equilib. 215 (2004) 227-236] and its combination with the Clausius-Clapeyron equation has been Studied. (C) 2009 Elsevier B.V. All rights reserved....

  11. Heat capacity measurements of sub-nanoliter volumes of liquids using bimaterial microchannel cantilevers

    Energy Technology Data Exchange (ETDEWEB)

    Khan, M. F.; Miriyala, N.; Hassanpourfard, M.; Thundat, T. [Ingenuity Lab, Edmonton, Alberta T6G 2R3 (Canada); Department of Chemical and Materials Engineering, University of Alberta, Edmonton, Alberta T6G 2R3 (Canada); Lee, J. [Department of Chemical and Materials Engineering, University of Alberta, Edmonton, Alberta T6G 2R3 (Canada); Department of Mechanical Engineering, Sogang University, 121-742 Seoul (Korea, Republic of); Kumar, A. [Department of Mechanical Engineering, University of Alberta, Edmonton, Alberta T6G 2R3 (Canada)

    2016-05-23

    Lab-on-a-Chip compatible techniques for thermal characterization of miniaturized volumes of liquid analytes are necessary in applications such as protein blotting, DNA melting, and drug development, where samples are either rare or volume-limited. We developed a closed-chamber calorimeter based on a bimaterial microchannel cantilever (BMC) for sub-nanoliter level thermal analysis. When the liquid-filled BMC is irradiated with infrared (IR) light at a specific wavelength, the IR absorption by the liquid analyte results in localized heat generation and the subsequent deflection of the BMC, due to a thermal expansion mismatch between the constituent materials. The time constant of the deflection, which is dependent upon the heat capacity of the liquid analyte, can be directly measured by recording the time-dependent bending of the BMC. We have used the BMC to quantitatively measure the heat capacity of five volatile organic compounds. With a deflection noise level of ∼10 nm and a signal-to-noise ratio of 68:1, the BMC offers a sensitivity of 30.5 ms/(J g{sup −1 }K{sup −1}) and a resolution of 23 mJ/(g K) for ∼150 pl liquid for heat capacity measurements. This technique can be used for small-scale thermal characterization of different chemical and biological samples.

  12. Excess heat capacity and entropy of mixing along the chlorapatite-fluorapatite binary join

    Science.gov (United States)

    Dachs, Edgar; Harlov, Daniel; Benisek, Artur

    2010-10-01

    The heat capacity at constant pressure, C p, of chlorapatite [Ca5(PO4)3Cl - ClAp], and fluorapatite [Ca5(PO4)3F - FAp], as well as of 12 compositions along the chlorapatite-fluorapatite join have been measured using relaxation calorimetry [heat capacity option of the physical properties measurement system (PPMS)] and differential scanning calorimetry (DSC) in the temperature range 5-764 K. The chlor-fluorapatites were synthesized at 1,375-1,220°C from Ca3(PO4)2 using the CaF2-CaCl2 flux method. Most of the chlor-fluorapatite compositions could be measured directly as single crystals using the PPMS such that they were attached to the sample platform of the calorimeter by a crystal face. However, the crystals were too small for the crystal face to be polished. In such cases, where the sample coupling was not optimal, an empirical procedure was developed to smoothly connect the PPMS to the DSC heat capacities around ambient T. The heat capacity of the end-members above 298 K can be represented by the polynomials: C {p/ClAp} = 613.21 - 2,313.90 T -0.5 - 1.87964 × 107 T -2 + 2.79925 × 109 T -3 and C {p/FAp} = 681.24 - 4,621.73 × T -0.5 - 6.38134 × 106 T -2 + 7.38088 × 108 T -3 (units, J mol-1 K-1). Their standard third-law entropy, derived from the low-temperature heat capacity measurements, is S° = 400.6 ± 1.6 J mol-1 K-1 for chlorapatite and S° = 383.2 ± 1.5 J mol-1 K-1 for fluorapatite. Positive excess heat capacities of mixing, Δ C {p/ex}, occur in the chlorapatite-fluorapatite solid solution around 80 K (and to a lesser degree at 200 K) and are asymmetrically distributed over the join reaching a maximum of 1.3 ± 0.3 J mol-1 K-1 for F-rich compositions. They are significant at these conditions exceeding the 2 σ-uncertainty of the data. The excess entropy of mixing, Δ S ex, at 298 K reaches positive values of 3-4 J mol-1 K-1 in the F-rich portion of the binary, is, however, not significantly different from zero across the join within its 2 σ-uncertainty.

  13. Reaction heats and heat capacity changes for intermediate steps of the ATP hydrolysis catalyzed by myosin subfragment 1.

    Science.gov (United States)

    Kodama, T

    1981-03-25

    The interaction of myosin Subfragment 1 with ATP in 0.1 M KCl containing 0.01 M MgCl2 and 0.02 M Tris/HCl (pH 8.0) was studied by microcalorimetry at temperatures of 4, 12, and 23 degrees C so that values of the heat capacity change (delta Cp) could be obtained for intermediate steps of the ATPase cycle. The delta Cp values are large compared to the value for the overall cycle, indicating that large changes in the hydrophobic effect are involved in transitions between different intermediate states. However, the heat capacity changes themselves show peculiar temperature dependences. Thus bindings of ATP and ADP to Subfragment 1, both of which are strongly exothermic processes, take place with large negative delta Cp of about -3 kJK-1 mol-1 between 4 and 12 degrees C but with very small delta Cp of 0.3-0.4 kJ K-1 mol-1 between 12 and 23 degrees C. On the contrary, the delta Cp for the endothermic hydrolysis of ATP bound to Subfragment 1 is positive (congruent to kJK-1 mol-1) in the lower temperature range but strongly negative (congruent to -4 kJK-1 mol-1) in the higher temperature range. The magnitude of delta Cp for the slow Pi dissociation process is similar but its sign is just opposite to that for the hydrolysis. These anomalous changes in the heat capacity may be due to the temperature-induced changes in a balance between large opposing effects which result from distinct, local conformation changes within the Subfragment 1 molecule.

  14. Development of energy efficient smart module with variable direction of heat flow, heat capacity and surface absorptivity(I)

    Energy Technology Data Exchange (ETDEWEB)

    Chun, W.K.; Lee, Y.J.; Lee, H.J. [Jeju University, Jeju (Korea, Republic of)] [and others

    1996-02-01

    This work has been carried out to develop thermal diode modules with variable direction of heat flow, heat capacity and surface absorptivity. The module can be used for space heating in winter and reduce the cooling load of buildings in summer. this concept could be also utilized for domestic hot water heating. The modules are categorized as follows; (1) Loop Type Smart Module, (2) Bayonet Type Smart Module, (3) Roller Type Smart Module, (4) Plane Tubeless Solar Collector and Storage System Utilizing the Bayonet Concept. Each system generally features either or both of the passive or active schemes. The Loop Type, in particular, is designed with the photo diode and microprocessor to harness the solar energy more aggressively. It is essential to contrive a totally new design concept apart from conventional ones to fully appreciate the availability of the sun`s energy. In this regard, the solar modules under investigation in the present study is of great significance. (author) 29 refs., 65 figs., 5 photos.

  15. Cooling and Heating Season Impacts of Right-Sizing of Fixed- and Variable-Capacity Heat Pumps With Attic and Indoor Ductwork

    Energy Technology Data Exchange (ETDEWEB)

    Cummings, James [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States); Withers, Charles [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States); Kono, Jamie [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States)

    2015-06-24

    A new generation of full variable-capacity air-conditioning (A/C) and heat pump units has come on the market that promises to deliver very high cooling and heating efficiency. The units are controlled differently than standard single-capacity (fixed-capacity) systems. Instead of cycling on at full capacity and cycling off when the thermostat is satisfied, the new units can vary their capacity over a wide range (approximately 40%–118% of nominal full capacity) and stay on for 60%–100% more hours per day than the fixed-capacity systems depending on load-to-capacity ratios. Two-stage systems were not evaluated in this research effort.

  16. Dynamic heat capacity of the east model and of a bead-spring polymer model.

    Energy Technology Data Exchange (ETDEWEB)

    McCoy, John Dwane (New Mexico Institute of Mining and Technology, Socorro, NM); Brown, Jonathan R. (New Mexico Institute of Mining and Technology, Socorro, NM); Adolf, Douglas Brian

    2011-10-01

    In this report we have presented a brief review of the glass transition and one means of characterizing glassy materials: linear and nonlinear thermodynamic oscillatory experiments to extract the dynamic heat capacity. We have applied these methods to the east model (a variation of the Ising model for glass forming systems) and a simple polymeric system via molecular dynamics simulation, and our results match what is seen in experiment. For the east model, since the dynamics are so simple, a mathematical model is developed that matches the simulated dynamics. For the polymeric system, since the system is a simulation, we can instantaneously 'quench' the system - removing all vibrational energy - to separate the vibrational dynamics from dynamics associated with particle rearrangements. This shows that the long-time glassy dynamics are due entirely to the particle rearrangements, i.e. basin jumping on the potential energy landscape. Finally, we present an extension of linear dynamic heat capacity to the nonlinear regime.

  17. Magnetic susceptibility and heat capacity of graphene in two-band Harrison model

    Science.gov (United States)

    Mousavi, Hamze; Bagheri, Mehran; Khodadadi, Jabbar

    2015-11-01

    Using a two-band tight-binding Harrison model and Green's function technique, the influences of both localized σ and delocalized π electrons on the density of states, the Pauli paramagnetic susceptibility, and the heat capacity of a graphene sheet are investigated. We witness an extension in the bandwidth and an increase in the number of Van-Hove singularities as well. As a notable point, besides the magnetic nature which includes diamagnetism in graphene-based nanosystems, a paramagnetic behavior associated with the itinerant π electrons could be occurred. Further, we report a Schottky anomaly in the heat capacity. This study asserts that the contribution of both σ and π electrons play dominant roles in the mentioned physical quantities.

  18. Vibrational Spectra and Heat Capacity of Methane, and the Speed of Sound

    Science.gov (United States)

    Tennis, Ronald; Bailey, Ryan; Henderson, Giles

    2000-12-01

    A two-part physical chemistry laboratory experiment is described in which students evaluate statistical mechanical theory by comparing a measured speed of sound and heat capacity with values predicted from vibrational spectra. In part 1 students measure the IR spectrum of CH4(g) and the Raman spectrum of CH4(l) to determine quantized vibrational energy spacings. Strong Raman scattering of a pulsed nitrogen laser beam is observed with a liquid methane sample in a custom cryogenic cell constructed from two side-arm test tubes and a length of Pyrex tube. These data are used with the statistical mechanics of a harmonic oscillator to calculate vibrational heat capacities and CP/CV; of CH4(g) and the speed of sound in CH4(g). In part 2, the predicted speed of sound is compared with an experimental value measured with a simple acoustic resonance cavity (Kundt's tube) exhausted to a Bunsen burner.

  19. Large-scale calculations of gas phase thermochemistry : Enthalpy of formation, standard entropy, and heat capacity

    OpenAIRE

    Ghahremanpour, Mohammad M.; van Maaren, Paul J.; Ditz, Jonas C.; Lindh, Roland; van der Spoel, David

    2016-01-01

    Large scale quantum calculations for molar enthalpy of formation (Delta(f) H-0), standard entropy (S-0), and heat capacity (C-V) are presented. A large data set may help to evaluate quantum thermochemistry tools in order to uncover possible hidden shortcomings and also to find experimental data that might need to be reinvestigated, indeed we list and annotate approximately 200 problematic thermochemistry measurements. Quantum methods systematically underestimate S-0 for flexible molecules in ...

  20. High-temperature heat capacity of samarium and erbium titanates with pyrochlore structure

    Science.gov (United States)

    Denisova, L. T.; Chumilina, L. G.; Denisov, V. M.; Ryabov, V. V.

    2017-12-01

    Titanates Sm2Ti2O7 and Er2Ti2O7 with pyrochlore structure have been prepared by solid-phase synthesis in air from stoichiometric Sm2O3 (Er2O3)-TiO2 mixtures sequentially at 1673 and 1773 K. Hightemperature heat capacity of the oxide compounds has been determined by differential scanning calorimetry. Their thermodynamic properties have been calculated from experimental temperature dependence C p = f( T).

  1. Emulsion stabilizing capacity of intact starch granules modified by heat treatment or octenyl succinic anhydride

    OpenAIRE

    Timgren, Anna; Rayner, Marilyn; Dejmek, Petr; Marku, Diana; Sjöö, Malin

    2013-01-01

    Starch granules are an interesting stabilizer candidate for food-grade Pickering emulsions. The stabilizing capacity of seven different intact starch granules for making oil-in-water emulsions has been the topic of this screening study. The starches were from quinoa; rice; maize; waxy varieties of rice, maize, and barley; and high-amylose maize. The starches were studied in their native state, heat treated, and modified by octenyl succinic anhydride (OSA). The effect of varying the continuous...

  2. A Heat Vulnerability Index: Spatial Patterns of Exposure, Sensitivity and Adaptive Capacity for Santiago de Chile

    Science.gov (United States)

    Palme, Massimo; de la Barrera, Francisco

    2016-01-01

    Climate change will worsen the high levels of urban vulnerability in Latin American cities due to specific environmental stressors. Some impacts of climate change, such as high temperatures in urban environments, have not yet been addressed through adaptation strategies, which are based on poorly supported data. These impacts remain outside the scope of urban planning. New spatially explicit approaches that identify highly vulnerable urban areas and include specific adaptation requirements are needed in current urban planning practices to cope with heat hazards. In this paper, a heat vulnerability index is proposed for Santiago, Chile. The index was created using a GIS-based spatial information system and was constructed from spatially explicit indexes for exposure, sensitivity and adaptive capacity levels derived from remote sensing data and socio-economic information assessed via principal component analysis (PCA). The objective of this study is to determine the levels of heat vulnerability at local scales by providing insights into these indexes at the intra city scale. The results reveal a spatial pattern of heat vulnerability with strong variations among individual spatial indexes. While exposure and adaptive capacities depict a clear spatial pattern, sensitivity follows a complex spatial distribution. These conditions change when examining PCA results, showing that sensitivity is more robust than exposure and adaptive capacity. These indexes can be used both for urban planning purposes and for proposing specific policies and measures that can help minimize heat hazards in highly dynamic urban areas. The proposed methodology can be applied to other Latin American cities to support policy making. PMID:27606592

  3. Heat Capacity Measurements of Sr2RuO4 Under Uni-axial Stress

    Science.gov (United States)

    Li, You-Sheng; Gibbs, Alexandra; MacKenzie, Andrew; Hicks, Clifford; Nicklas, Michael

    One of the most-discussed possible pairing symmetries of the superconductor Sr2RuO4 is px + /-ipy. By applying in-plane uniaxial stress, the degeneracy of the px and py components should be lifted, yielding two critical temperatures (Tc) . Hicks et al. observed an increase of Tc of Sr2RuO4 under both compressive and tensile stress, and did not find evidence for splitting of transition. However, that result was based on magnetic susceptibility measurements, which would be sensitive only to the upper transition. For a direct test of possible splitting, we measure the heat capacity of Sr2RuO4 under uniaxial stress. To do so, we have developed an approach to measure heat capacity under non-adiabatic conditions. We have observed the increase in Tc under compressive strain, providing the first thermodynamic evidence for the strain-induced increase in Tc of Sr2RuO4, and also resolve strong strain-induced changes in the normal-state heat capacity.

  4. Improved exercise capacity in the heat followed by coconut water consumption

    Directory of Open Access Journals (Sweden)

    Orlando Laitano

    2014-03-01

    Full Text Available The aim of the present study was to assess the effects of prior ingestion of coconut water on fluid retention and exercise capacity in the heat as well as signs of gastrointestinal distress. Eight physically active men were recruited (age 23 ± 3 years, height 176 ± 6 cm, body mass 78 ± 7 kg and performed three exercise capacity trials on a cycle ergometer in the heat (34 ± 1°C after the ingestion of one of the following drinks: a plain water (PW, b flavored drink (FD, and c coconut water (CW. Ingestion of CWresulted in a longer time to exhaustion (p=0.029. Likewise, participants achieved a higher heart rate in the CW session when compared to the other trials (PW 183 ± 5 bpm, FD 184 ± 8 bpm, and CW 189 ± 8 bpm, p<0.05 and a reduced urine output after the coconut water ingestion (PW 214 ± 85 ml, FD 267 ± 90 ml, and CW 161 ± 73 ml, p<0.05 indicating a higher fluid retention of coconut water in comparison to plain water and the flavored drink. These results demonstrate that previous ingestion of coconut water improves exercise capacity in the heat and provide a reduced urine output in comparison to plain water and flavored drink. Also there is no evidence for GI distress.

  5. Prevalence of Temperature Dependent Heat Capacity Changes in Protein-DNA Interactions

    Energy Technology Data Exchange (ETDEWEB)

    Liu, C.-C.; Richard, A.J.; Kausiki, D.; LiCata, V.J.

    2009-05-19

    A large, negative {Delta}Cp of DNA binding is a thermodynamic property of the majority of sequence-specific DNA-protein interactions, and a common, but not universal property of non-sequence-specific DNA binding. In a recent study of the binding of Taq polymerase to DNA, we showed that both the full-length polymerase and its 'Klentaq' large fragment bind to primed-template DNA with significant negative heat capacities. Herein, we have extended this analysis by analyzing this data for temperature-variable heat capacity effects ({Delta}{Delta}Cp), and have similarly analyzed an additional 47 protein-DNA binding pairs from the scientific literature. Over half of the systems examined can be easily fit to a function that includes a {Delta}{Delta}Cp parameter. Of these, 90% display negative {Delta}{Delta}Cp values, with the result that the {Delta}Cp of DNA binding will become more negative with rising temperature. The results of this collective analysis have potentially significant consequences for current quantitative theories relating {Delta}Cp values to changes in accessible surface area, which rely on the assumption of temperature invariance of the {Delta}Cp of binding. Solution structural data for Klentaq polymerase demonstrate that the observed heat capacity effects are not the result of a coupled folding event.

  6. Application of Neumann-Kopp rule for the estimation of heat capacity of mixed oxides

    Energy Technology Data Exchange (ETDEWEB)

    Leitner, J., E-mail: jindrich.leitner@vscht.cz [Department of Solid State Engineering, Institute of Chemical Technology Prague, Technicka 5, 166 28 Prague 6 (Czech Republic); Vonka, P. [Department of Physical Chemistry, Institute of Chemical Technology Prague, Technicka 5, 166 28 Prague 6 (Czech Republic); Sedmidubsky, D. [Department of Inorganic Chemistry, Institute of Chemical Technology Prague, Technicka 5, 166 28 Prague 6 (Czech Republic); European Commission, JRC, Institute for Transuranium Elements, Postbox 2340, D-76125 Karlsruhe (Germany); Svoboda, P. [Department of Condensed Matter Physics, Faculty of Mathematics and Physics, Charles University, Ke Karlovu 5, 120 00 Prague 2 (Czech Republic)

    2010-01-10

    The empirical Neumann-Kopp rule (NKR) for the estimation of temperature dependence of heat capacity of mixed oxide is analyzed. NKR gives a reasonable estimate of C{sub pm} for most mixed oxides around room temperature, but at both low and high temperatures the accuracy of the estimate is substantially lowered. At very low temperatures, the validity of NKR is shown to be predominantly determined by the relation between the characteristic Debye and Einstein temperatures of a mixed oxide and its constituents. At high temperatures, the correlation between their molar volumes, volume expansion coefficients and compressibilities takes the dominance. In cases where the formation of a mixed oxide is not accompanied by any volume change, the difference between dilatation contributions to heat capacity of a mixed oxide and its constituents is exclusively negative. It turns out that in the high-temperature range, where the contribution of harmonic lattice vibrations approached the 3NR limit, {Delta}{sub ox}C{sub p} assumes negative values. For more complex oxides whose heat capacity has contributions from terms such as magnetic ordering, electronic excitations, the applicability of NKR is only restricted to lattice and dilatation terms.

  7. Electrolytic conductivity and molar heat capacity of two aqueous solutions of ionic liquids at room-temperature: Measurements and correlations

    Energy Technology Data Exchange (ETDEWEB)

    Lin Peiyin [R and D Center for Membrane Technology and Department of Chemical Engineering, Chung Yuan Christian University, Chung Li 32023, Taiwan (China); Soriano, Allan N. [R and D Center for Membrane Technology and Department of Chemical Engineering, Chung Yuan Christian University, Chung Li 32023, Taiwan (China); School of Chemical Engineering and Chemistry, Mapua Institute of Technology, Manila 1002 (Philippines); Leron, Rhoda B. [R and D Center for Membrane Technology and Department of Chemical Engineering, Chung Yuan Christian University, Chung Li 32023, Taiwan (China); Li Menghui, E-mail: mhli@cycu.edu.t [R and D Center for Membrane Technology and Department of Chemical Engineering, Chung Yuan Christian University, Chung Li 32023, Taiwan (China)

    2010-08-15

    As part of our systematic study on physicochemical characterization of ionic liquids, in this work, we report new measurements of electrolytic conductivity and molar heat capacity for aqueous solutions of two 1-ethyl-3-methylimidazolium-based ionic liquids, namely: 1-ethyl-3-methylimidazolium dicyanamide and 1-ethyl-3-methylimidazolium 2-(2-methoxyethoxy) ethylsulfate, at normal atmospheric condition and for temperatures up to 353.2 K. The electrolytic conductivity and molar heat capacity were measured by a commercial conductivity meter and a differential scanning calorimeter (DSC), respectively. The estimated experimental uncertainties for the electrolytic conductivity and molar heat capacity measurements were {+-}1% and {+-}2%, respectively. The property data are reported as functions of temperature and composition. A modified empirical equation from another researcher was used to correlate the temperature and composition dependence of the our electrolytic conductivity results. An excess molar heat capacity expression derived using a Redlich-Kister type equation was used to represent the temperature and composition dependence of the measured molar heat capacity and calculated excess molar heat capacity of the solvent systems considered. The correlations applied represent the our measurements satisfactorily as shown by an acceptable overall average deviation of 6.4% and 0.1%, respectively, for electrolytic conductivity and molar heat capacity.

  8. A new experimental method to determine specific heat capacity of inhomogeneous concrete material with incorporated microencapsulated-PCM

    DEFF Research Database (Denmark)

    Pomianowski, Michal Zbigniew; Heiselberg, Per; Jensen, Rasmus Lund

    2014-01-01

    The study presented in this paper focuses on an experimental investigation of the specific heat capacity as a function of the temperature Cp (T) of concrete mixed with various amounts of phase change material (PCM). The tested specimens are prepared by directly mixing concrete and microencapsulated...... PCM. This paper describes the development of the new material and the experimental set-up to determine the specific heat capacity of the PCM concrete material. Moreover, various methods are proposed and compared to calculate the specific heat capacity of the PCM concrete. Finally, it is hoped...

  9. Cryostat for semiautomatic measurement of heat capacity and elastic moduli between 1.6 and 400 K

    Science.gov (United States)

    Hirao, Kazuyuki; Soga, Naohiro

    1983-11-01

    An adiabatic cryostat system for the measurement of either heat capacity or elastic moduli was constructed. The vacuum system, electronic equipment to achieve the adiabatic conditions, and instruments for measurements are described. The cube resonance method used for measurement of elastic moduli is shown. Test measurements on the heat capacity of α-Al2O3 show agreement within ±1% of the literature values. The results of heat capacity and elastic moduli measurements on optical fiberglass are described and compared with other data.

  10. Power Output Stability Research for Harvesting Automobile Exhaust Energy with Heat Capacity Material as Intermediate Medium

    Science.gov (United States)

    Xiao, Longjie; He, Tianming; Mei, Binyu; Wang, Yiping; Wang, Zongsong; Tan, Gangfeng

    2018-01-01

    Automobile exhaust energy thermoelectric utilization can promote energy-saving and emission-reduction. Unexpected urban traffic conditions lead to the hot-end temperature instability of the exhaust pipe-mounted thermoelectric generator (TEG), and influence the TEG power generation efficiency. The heat conduction oil circulation located at the hot-end could smooth the temperature fluctuation, at the expense of larger system size and additional energy supply. This research improves the TEG hot-end temperature stability by installing solid heat capacity material (SHCM) to the area between the outer wall of the exhaust pipe and the TEG, which has the merits of simple structure, light weight and no additional energy consumption. The exhaust temperature and flow rate characteristics with various driving conditions are firstly studied for the target engine. Then the convective heat transfer models of SHCM's hot-end and thermoelectric material's cold-end are established. Meanwhile, SHCM thermal properties' effects on the amplitude and response speed of the TEG hot-end temperature are studied. The candidate SHCM with the characteristics of low thermal resistance and high heat capacity is determined. And the heat transfer model going through from TEG's hot-end to the cold-end is established. The results show that the SHCM significantly improves the TEG hot-end temperature stability but slightly reduces the average power output. When the engine working conditions change a lot, the SHCM's improvement on the TEG hot-end temperature stability is more significant, but the reduction of the average power output becomes more remarkable.

  11. Thermodynamic properties of zeolites: low-temperature heat capacities and thermodynamic functions for phillipsite and clinoptilolite. Estimates of the thermochemical properties of zeolitic water at low temperature.

    Science.gov (United States)

    Hemingway, B.S.; Robie, R.A.

    1984-01-01

    Measured heat capacities between 15 and 305 K and calculated heat capacities, entropies, enthalpy functions and Gibbs energy functions are reported and analysed for phillipsite and clinoptilolite. - J.A.Z.

  12. Guide for the calculation of heating capacity and heating coils for deep tanks / Handleiding bij de berekening van verwarmingskapasiteit en spiraallengte voor dieptanks

    NARCIS (Netherlands)

    Heeden, D.J. van der; Koppenol, A.D.

    1972-01-01

    This report deals with a method for calculating the heating capacity and the length of heating coils, required for deep tanks in dry cargo ships. It is based on the theory of natural convection and on experiments, carried out on tanks loaded with mineral oils. The calculating method is set up for

  13. Unprecedented Integral-Free Debye Temperature Formulas: Sample Applications to Heat Capacities of ZnSe and ZnTe

    National Research Council Canada - National Science Library

    R. Pässler

    2017-01-01

    Detailed analytical and numerical analyses are performed for combinations of several complementary sets of measured heat capacities, for ZnSe and ZnTe, from the liquid-helium region up to 600 K. The isochoric (harmonic...

  14. Exercise capacity in the heat is greater in the morning than in the evening in man.

    Science.gov (United States)

    Hobson, Ruth M; Clapp, Emma L; Watson, Phillip; Maughan, Ronald J

    2009-01-01

    This study investigated the effect of time of day on endurance exercise capacity in a warm environment. Nine males cycled to exhaustion at 65% .VO2peak in an ambient temperature of 35 degrees C (60% relative humidity) at 0645 h (AM) and 1845 h (PM). Rectal temperature (Tc), skin temperature (Tsk), and heart rate (HR) were recorded and blood and expired air samples collected at rest every 5 min during exercise and during recovery. Time to exhaustion was longer in the AM trial (45.8 +/- 10.7 min) than in the PM trial (40.5 +/- 9.0 min; P = 0.009). Resting Tc was lower in the AM trial and remained lower for the first 25 min of exercise (P exercise (P exercise capacity in the heat was significantly greater in the morning than the evening, possibly due to a lower initial Tc.

  15. Thermal analysis method of high capacity communications satellite with heat pipes

    Science.gov (United States)

    Tsunoda, Hiroaki; Nakajima, Katsuhiko; Miyasaka, Akihiro

    Thermal analysis method for heat pipe embedded communications equipment panel is treated in this paper. The main problem of the thermal analysis is how to construct the mathematical model under the limitation of computer CPU memory size. The mathematical model for the heat pipe embedded panel is first established based on the experiments. The essence of this method is to divide panel area into several small regions and perform thermal analysis independently using the fact of low thermal conductivity of honeycomb sandwich panel. To check the correctness of this method, the experiment using the test panel which thermally simulates the north communications equipment panel of two-ton class high capacity communications satellite has been conducted. The experiment shows the method works well.

  16. Heat capacities of xenotime-type ceramics: An accurate ab initio prediction

    Science.gov (United States)

    Ji, Yaqi; Beridze, George; Bosbach, Dirk; Kowalski, Piotr M.

    2017-10-01

    Because of ability to incorporate actinides into their structure, the lanthanide phosphate ceramics (LnPO4) are considered as potential matrices for the disposal of nuclear waste. Here we present highly reliable ab initio prediction of the variation of heat capacities and the standard entropies of these compounds in zircon structure along lanthanide series (Ln = Dy, …,Lu) and validate them against the existing experimental data. These data are helpful for assessment of thermodynamic parameters of these materials in the context of using them as matrices for immobilization of radionuclides for the purpose of nuclear waste management.

  17. A heat capacity anomaly of the superconducting transition in a ferromagnetic superconductor UGe{sub 2}

    Energy Technology Data Exchange (ETDEWEB)

    Tateiwa, Naoyuki; Kobayashi, Tatsuo C.; Amaya, Kiichi; Haga, Yoshinori; Settai, Rikio; Onuki, Yoshichika

    2003-05-15

    We performed the heat capacity, C(T), measurement under high pressure on a ferromagnetic superconductor UGe{sub 2}, in order to study the pressure dependence of the anomaly in C(T) associated with the superconducting transition. A clear peak appears only around a critical pressure P{sub c}* where an another transition temperature T* becomes 0 K. This result suggests that a bulk superconducting phase exists in the narrower pressure region around P{sub c}* than those clarified by previous studies.

  18. Analytical evaluation of thermal conductance and heat capacities of one-dimensional material systems

    Energy Technology Data Exchange (ETDEWEB)

    Saygi, Salih [Department of Physics, Gaziosmanpasa University, Tokat, 60200 Turkey (Turkey)

    2014-02-15

    We theoretically predict some thermal properties versus temperature dependence of one dimensional (1D) material nanowire systems. A known method is used to provide an efficient and reliable analytical procedure for wide temperature range. Predicted formulas are expressed in terms of Bloch-Grüneisen functions and Debye functions. Computing results has proved that the expressions are in excellent agreement with the results reported in the literature even if it is in very low dimension limits of nanowire systems. Therefore the calculation method is a fully predictive approach to calculate thermal conductivity and heat capacities of nanowire material systems.

  19. Mössbauer and heat capacity studies of ErZnSn2

    Directory of Open Access Journals (Sweden)

    Łątka Kazimierz

    2017-06-01

    Full Text Available Heat capacity results obtained for the intermetallic compound ErZnSn2 were re-analysed to also consider, apart from the classical Debye model, the anharmonicity of the crystal lattice and the proper set of Einstein modes. The 119mSn Mössbauer technique was applied to derive the hyperfine interaction parameters characteristic of the two inequivalent crystallographic Sn sites in the compound studied. Quadrupole interaction constants, as measured by 119mSn Mössbauer spectroscopy, allowed for estimations of Vzz components of the electric field gradient tensor that exist at both Sn sites in the discussed compound.

  20. Heat capacity measurements of atoms and molecules adsorbed on evaporated metal films

    Energy Technology Data Exchange (ETDEWEB)

    Kenny, T.W.

    1989-05-01

    Investigations of the properties of absorbed monolayers have received great experimental and theoretical attention recently, both because of the importance of surface processes in practical applications such as catalysis, and the importance of such systems to the understanding of the fundamentals of thermodynamics in two dimensions. We have adapted the composite bolometer technology to the construction of microcalorimeters. For these calorimeters, the adsorption substrate is an evaporated film deposited on one surface of an optically polished sapphire wafer. This approach has allowed us to make the first measurements of the heat capacity of submonolayer films of /sup 4/He adsorbed on metallic films. In contrast to measurements of /sup 4/He adsorbed on all other insulating substrates, we have shown that /sup 4/He on silver films occupies a two-dimensional gas phase over a broad range of coverages and temperatures. Our apparatus has been used to study the heat capacity of Indium flakes. CO multilayers, /sup 4/He adsorbed on sapphire and on Ag films and H/sub 2/ adsorbed on Ag films. The results are compared with appropriate theories. 68 refs., 19 figs.

  1. Influence of heat treatment on antioxidant capacity and (poly)phenolic compounds of selected vegetables.

    Science.gov (United States)

    Juániz, Isabel; Ludwig, Iziar A; Huarte, Estibaliz; Pereira-Caro, Gema; Moreno-Rojas, Jose Manuel; Cid, Concepción; De Peña, María-Paz

    2016-04-15

    The impact of cooking heat treatments (frying in olive oil, frying in sunflower oil and griddled) on the antioxidant capacity and (poly)phenolic compounds of onion, green pepper and cardoon, was evaluated. The main compounds were quercetin and isorhamnetin derivates in onion, quercetin and luteolin derivates in green pepper samples, and chlorogenic acids in cardoon. All heat treatments tended to increase the concentration of phenolic compounds in vegetables suggesting a thermal destruction of cell walls and sub cellular compartments during the cooking process that favor the release of these compounds. This increase, specially that observed for chlorogenic acids, was significantly correlated with an increase in the antioxidant capacity measured by DPPH (r=0.70). Griddled vegetables, because of the higher temperature applied during treatment in comparison with frying processes, showed the highest amounts of phenolic compounds with increments of 57.35%, 25.55% and 203.06% compared to raw onion, pepper and cardoon, respectively. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. An automated flow calorimeter for heat capacity and enthalpy measurements at elevated temperatures and pressures

    Energy Technology Data Exchange (ETDEWEB)

    Yesavage, V.F.

    1990-08-31

    The need for highly accurate thermal property data for a broad range of new application fluids is well documented. To facilitate expansion of the current thermophysical database, an automated flow calorimeter was developed for the measurement of highly accurate isobaric heat capacities and enthalpies of fluids at elevated temperatures and pressures. The experimental technique utilizes traditional electrical power input, adiabatic flow calorimetry with a precision metering pump that eliminates the need for on-line flow rate monitoring. In addition, a complete automation system, greatly simplifies the operation of the apparatus and increases the rapidity of the measurement process. The range over which the instrument was tested, was 300--600 K and 0--12 Mpa, although the calorimeter should perform up to the original design goals of 700 K and 30 MPa. The new flow calorimeter was evaluated by measuring the mean, isobaric, specific heat capacities of liquid water and n-pentane. These experiments yielded an average deviation from the standard literature data of +0.02% and a total variation of 0.05%. Additional data analysis indicated that the overall measurement uncertainty was conservatively estimated as 0.2% with an anticipated precision of 0.1--0.15% at all operating conditions. 44 refs., 27 figs., 2 tabs.

  3. Quantum thermodynamics from the nonequilibrium dynamics of open systems: Energy, heat capacity, and the third law

    Science.gov (United States)

    Hsiang, J.-T.; Chou, C. H.; Subaşı, Y.; Hu, B. L.

    2018-01-01

    In a series of papers, we intend to take the perspective of open quantum systems and examine from their nonequilibrium dynamics the conditions when the physical quantities, their relations, and the laws of thermodynamics become well defined and viable for quantum many-body systems. We first describe how an open-system nonequilibrium dynamics (ONEq) approach is different from the closed combined system + environment in a global thermal state (CGTs) setup. Only after the open system equilibrates will it be amenable to conventional thermodynamics descriptions, thus quantum thermodynamics (QTD) comes at the end rather than assumed in the beginning. The linkage between the two comes from the reduced density matrix of ONEq in that stage having the same form as that of the system in the CGTs. We see the open-system approach having the advantage of dealing with nonequilibrium processes as many experiments in the near future will call for. Because it spells out the conditions of QTD's existence, it can also aid us in addressing the basic issues in quantum thermodynamics from first principles in a systematic way. We then study one broad class of open quantum systems where the full nonequilibrium dynamics can be solved exactly, that of the quantum Brownian motion of N strongly coupled harmonic oscillators, interacting strongly with a scalar-field environment. In this paper, we focus on the internal energy, heat capacity, and the third law. We show for this class of physical models, amongst other findings, the extensive property of the internal energy, the positivity of the heat capacity, and the validity of the third law from the perspective of the behavior of the heat capacity toward zero temperature. These conclusions obtained from exact solutions and quantitative analysis clearly disprove claims of negative specific heat in such systems and dispel allegations that in such systems the validity of the third law of thermodynamics relies on quantum entanglement. They are

  4. Emulsion stabilizing capacity of intact starch granules modified by heat treatment or octenyl succinic anhydride.

    Science.gov (United States)

    Timgren, Anna; Rayner, Marilyn; Dejmek, Petr; Marku, Diana; Sjöö, Malin

    2013-03-01

    Starch granules are an interesting stabilizer candidate for food-grade Pickering emulsions. The stabilizing capacity of seven different intact starch granules for making oil-in-water emulsions has been the topic of this screening study. The starches were from quinoa; rice; maize; waxy varieties of rice, maize, and barley; and high-amylose maize. The starches were studied in their native state, heat treated, and modified by octenyl succinic anhydride (OSA). The effect of varying the continuous phase, both with and without salt in a phosphate buffer, was also studied. Quinoa, which had the smallest granule size, had the best capacity to stabilize oil drops, especially when the granules had been hydrophobically modified by heat treatment or by OSA. The average drop diameter (d 32) in these emulsions varied from 270 to 50 μm, where decreasing drop size and less aggregation was promoted by high starch concentration and absence of salt in the system. Of all the starch varieties studied, quinoa had the best overall emulsifying capacity, and OSA modified quinoa starch in particular. Although the size of the drops was relatively large, the drops themselves were in many instances extremely stable. In the cases where the system could stabilize droplets, even when they were so large that they were visible to the naked eye, they remained stable and the measured droplet sizes after 2 years of storage were essentially unchanged from the initial droplet size. This somewhat surprising result has been attributed to the thickness of the adsorbed starch layer providing steric stabilization. The starch particle-stabilized Pickering emulsion systems studied in this work has potential practical application such as being suitable for encapsulation of ingredients in food and pharmaceutical products.

  5. Analysis of heat capacity and Mössbauer data for LuZnSn2 compound

    Directory of Open Access Journals (Sweden)

    Łątka Kazimierz

    2015-03-01

    Full Text Available New analysis of heat capacity data is presented for LuZnSn2 compound that takes into account anharmonic effects together with the existence of Einstein modes. 119mSn Mössbauer spectroscopy was used to monitor the hyperfine parameters at the two crystallographically inequivalent Sn sites in the studied compound. The problem of non-unique mathematical resonance spectrum description and the problem how to choose physically meaningful set of hyperfine parameters will be thoroughly discussed. Measured quadrupole interaction constants by 119mSn Mössbauer spectroscopy give estimations for Vzz component of electric field gradient tensor at both Sn sites in LuZnSn2.

  6. Temperature Dependence of the Molar Heat Capacity for Ferromagnets Within the Mean Field Theory

    Science.gov (United States)

    Fernández Rodríguez, J.; Blanco, J. A.

    2005-01-01

    We describe, using the Mean Field Theory, a detailed analysis of the magnetic contribution to the molar heat capacity Cmag for ferromagnetic systems. This calculation is designed to be used as a teaching homework problem for physics undergraduates. The description emphasises that Cmag at the transition temperature TC is characterised by the existence of a simple jump discontinuity anomaly, but when the temperature is lowered down to 0 K the shape of Cmag depends strongly on the magnitude of the spin S. In fact, the appearance of a shoulder in Cmag for S > 3/2 is expected. The origin of this shoulder could be understood as a Schottky-like anomaly in the ordered state. These physical results are in good agreement with those from real systems, and give the student a valuable insight into the behaviour of the thermodynamical response of a ferromagneticmaterial.

  7. Empirical equations for viscosity and specific heat capacity determination of paraffin PCM and fatty acid PCM

    Science.gov (United States)

    Barreneche, C.; Ferrer, G.; Palacios, A.; Solé, A.; Inés Fernández, A.; Cabeza, L. F.

    2017-10-01

    Phase change materials (PCM) used in thermal energy storage (TES) systems have been presented, over recent years, as one of the most effective options in energy storage. Paraffin and fatty acids are some of the most used PCM in TES systems, as they have high phase change enthalpy and in addition they do not present subcooling nor hysteresis and have proper cycling stability. The simulations and design of TES systems require the knowledge of the thermophysical properties of PCM. Thermal conductivity, viscosity, specific heat capacity (Cp) can be experimentally determined, but these are material and time consuming tasks. To avoid or to reduce them, and to have reliable data without the need of experimentation, thermal properties can be calculated by empirical equations. In this study, five different equations are given to calculate the viscosity and specific heat capacity of fatty acid PCM and paraffin PCM. Two of these equations concern, respectively, the empirical calculation of the viscosity and liquid Cp of the whole paraffin PCM family, while the other three equations presented are for the corresponding calculation of viscosity, solid Cp, liquid Cp of the whole fatty acid family of PCM. Therefore, this study summarize the work performed to obtain the main empirical equations to measure the above mentioned properties for whole fatty acid PCM family and whole paraffin PCM family. Moreover, empirical equations have been obtained to calculate these properties for other materials of these PCM groups and these empirical equations can be extrapolated for PCM with higher or lower phase change temperatures within a lower relative error 4%.

  8. Cryogenic Heat Load and Refrigeration Capacity Management at the Large Hadron Collider (LHC)

    CERN Document Server

    Claudet, S; Serio, L; Tavian, L; Van Weelderen, R; Wagner, U

    2009-01-01

    The Large Hadron Collider (LHC) is a 26.7 km high-energy proton and ion collider based on several thousand high-field superconducting magnets operating in superfluid helium below 2 K, now under commissioning at CERN. After a decade of development of the key technologies, the project was approved for construction in 1994 and the industrial procurement for the cryogenic system launched in 1997, concurrently with the completion of the R&D program. This imposed to base the sizing of the refrigeration plants on estimated and partially measured values of static and dynamic heat loads, with adequate uncertainty and overcapacity coefficients to cope with unknowns in machine configuration and in physical processes at work. With the cryogenic commissioning of the complete machine, full-scale static heat loads could be measured, thus confirming the correctness of the estimates and the validity of the approach, and safeguarding excess refrigeration capacity for absorbing the beam-induced dynamic loads. The metho...

  9. Measurement uncertainties when determining heat rate, isentropic efficiency and swallowing capacity

    Energy Technology Data Exchange (ETDEWEB)

    Snygg, U.

    1996-05-01

    The objective of the project was to determine the uncertainties when calculating heat rate, isentropic efficiencies and swallowing capacities of power plants. Normally when a power plant is constructed, the supplier also guarantee some performance values, e.g. heat rate. When the plant is built and running under normal conditions, an evaluation is done and the guarantee values are checked. Different measured parameters influence the calculated value differently, and therefore a sensitivity factor can be defined as the sensitivity of a calculated value when the measured value is changing. The product of this factor and the uncertainty of the measured parameter gives an error of the calculated value. For every measured parameter, the above given factor has to be determined and then the root square sum gives the overall uncertainty of the calculated parameter. To receive acceptable data during the evaluation of the plant, a test code is to be followed. The test code also gives guidelines how big the errors of the measurements are. In this study, ASME PTC6 and DIN 1943 were used. The results show that not only the test code was of vital importance, but also the distribution of the power output of the HP-IP turbines contra LP turbines. A higher inlet pressure of the LP turbine gives a smaller uncertainty of the isentropic efficiency. An increase from 6 to 13 bar will lower the uncertainty 1.5 times. 10 refs, 24 figs, 23 tabs, 5 appendixes

  10. Heat capacity and density of solutions of calcium and cadmium nitrates in N-methylpyrrolidone at 298.15 K

    Science.gov (United States)

    Novikov, A. N.; Rassokhina, L. Yu.

    2013-08-01

    The heat capacity and density of solutions of calcium and cadmium nitrates in N-methylpyrrolidone (MP) at 298.15 K are studied by calorimetry and densimetry. The obtained data are discussed in relation to certain features of solvation and complex formation in solutions of these salts. The standard partial molar heat capacities and volumes (overline {C_{p^2 }^0 } and overline {V_2^0 }) of the electrolytes in MP are calculated. The standard heat capacities overline {C_{p^i }^0 } and volumes overline {V_i^0 } of Ca2+ and Cd2+ ions in MP at 298.15 K were determined, along with the contribution from specific interactions to the values of overline {C_{p^i }^0 } and overline {V_i^0 } of Cd2+ ions in MP solution.

  11. Heat capacity and density of solutions of lithium and sodium nitrates in N-methylpyrrolidone at 298.15 K

    Science.gov (United States)

    Novikov, A. N.

    2013-09-01

    The heat capacity and density of solutions of lithium and sodium nitrates in N-methylpyrrolidone (MP) at 298.15 K are studied by calorimetry and densimetry. The standard partial molar heat capacities and volumes ( C¯ p,2° and V¯ 2°) of LiNO3 and NaNO3 in MP are calculated. The standard heat capacities C¯ p,i ° and volumes V¯ i ° of Li+ and Na+ ions in MP at 298.15 K are determined on the basis of a proposed scale of ionic contributions of C¯ p,2° and V¯ 2° values. The obtained data are discussed in relation to certain features of solvation in solutions of the investigated salts.

  12. Effect of crystalline electric field on heat capacity of LnBaCuFeO5 (Ln = Gd, Ho, Yb)

    Science.gov (United States)

    Lal, Surender; Mukherjee, K.; Yadav, C. S.

    2018-02-01

    Structural, magnetic and thermodynamic properties of layered perovskite compounds LnBaCuFeO5 (Ln = Ho, Gd, Yb) have been investigated. Unlike the iso-structural compound YBaCuFeO5, which shows commensurate antiferromagnetic to incommensurate antiferromagnetic ordering below ∼200 K, the studied compounds do not show any magnetic transition in measured temperature range of 2-350 K. The high temperature heat capacity of the compounds is understood by employing contributions from both optical and acoustic phonons. At low temperature, the observed upturn in the heat capacity is attributed to the Schottky anomaly. The magnetic field dependent heat capacity shows the variation in position of the anomaly with temperature, which appears due to the removal of ground state degeneracy of the rare earth ions, by the crystalline electric field.

  13. Heat capacity and Joule-Thomson coefficient of selected n-alkanes at 0.1 and 10 MPa in broad temperature ranges

    DEFF Research Database (Denmark)

    Regueira Muñiz, Teresa; Varzandeh, Farhad; Stenby, Erling Halfdan

    2017-01-01

    Isobaric heat capacity of six n-alkanes, i.e. n-hexane, n-octane, n-decane, n-dodecane, n-tetradecane and n-hexadecane, was determined with a Calvet type differential heat-flux calorimeter at 0.1 and 10 MPa in a broad temperature range. The measured isobaric heat capacity data were combined...

  14. EXPERIENCE OF UTILIZATION OF CAPACITY BANKS AND SCHEMES OF FREQUENCY REGULATION IN MUNICIPAL CENTRALIZED HEATING SYSTEM OF CHISINAU

    Directory of Open Access Journals (Sweden)

    CHERNEI M

    2013-04-01

    Full Text Available The current paper provides a brief summary of the district heating system of the municipality Chisinau, including heat power sources, heat distribution network, production and consumption development over the past two decades and other data. Also, the priority investment projects realized by JSC "Termocom" are being presented. The company had implemented an automated monitoring system for the heat power production, transportation and distribution. For many years, the company used bellows pipes with polyurethane insulation, ball valves and plate heat exchangers. 14 out of 21 district heating boiler stations were upgraded 10 were completely automated having as a result no further need in full-time duty personnel there. The experience gained in the implementation of capacity banks and frequency inverters, summarizing the benefits and achieved results, is also presented in the current paper. It is to be underlined that in 2011 the company achieved decrease in electricity consumption by about 30% in comparison with 2005.

  15. Negative heat capacity in the critical region of nuclear fragmentation: an experimental evidence of the liquid-gas phase transition

    Science.gov (United States)

    D'Agostino, M.; Gulminelli, F.; Chomaz, P.; Bruno, M.; Cannata, F.; Bougault, R.; Gramegna, F.; Iori, I.; Le Neindre, N.; Margagliotti, G. V.; Moroni, A.; Vannini, G.

    2000-02-01

    An experimental indication of negative heat capacity in excited nuclear systems is inferred from the event by event study of energy fluctuations in Au quasi-projectile sources formed in Au+Au collisions at 35 A.MeV. Equilibrated events are selected and the excited source configuration is reconstructed through a calorimetric analysis of its de-excitation products. Fragment partitions show signs of a critical behavior at about 4.5 A.MeV excitation energy. Around this value the heat capacity shows a negative branch providing a direct evidence of a first order liquid gas phase transition.

  16. Heat capacity and thermodynamic functions of thulium orthophosphate TmPO4 in the range of 10-1350 K

    Science.gov (United States)

    Ryumin, M. A.; Gurevich, V. M.; Khoroshilov, A. V.; Tyurin, A. V.; Gavrichev, K. S.

    2017-12-01

    The heat capacity of TmPO4 in temperature ranges of 9.11-346.05 and 304.6-1344.6 K is measured via adiabatic and differential scanning calorimetry, respectively. The measurement data are used to calculate the temperature dependences of the heat capacity, entropy, change in enthalpy, and reduced Gibbs energy of TmPO4 in the range of 10-1344 K. The Gibbs energy of formation of thulium orthophosphate from elements Δf G 0(298.15 K) is determined.

  17. Age-related differences in heat loss capacity occur under both dry and humid heat stress conditions.

    Science.gov (United States)

    Larose, Joanie; Boulay, Pierre; Wright-Beatty, Heather E; Sigal, Ronald J; Hardcastle, Stephen; Kenny, Glen P

    2014-07-01

    This study examined the progression of impairments in heat dissipation as a function of age and environmental conditions. Sixty men (n = 12 per group; 20-30, 40-44, 45-49, 50-54, and 55-70 yr) performed four intermittent exercise/recovery cycles for a duration of 2 h in dry (35°C, 20% relative humidity) and humid (35°C, 60% relative humidity) conditions. Evaporative heat loss and metabolic heat production were measured by direct and indirect calorimetry, respectively. Body heat storage was measured as the temporal summation of heat production and heat loss during the sessions. Evaporative heat loss was reduced during exercise in the humid vs. dry condition in age groups 20-30 (-17%), 40-44 (-18%), 45-49 (-21%), 50-54 (-25%), and 55-70 yr (-20%). HE fell short of being significantly different between groups in the dry condition, but was greater in age group 20-30 yr (279 ± 10 W) compared with age groups 45-49 (248 ± 8 W), 50-54 (242 ± 6 W), and 55-70 yr (240 ± 7 W) in the humid condition. As a result of a reduced rate of heat dissipation predominantly during exercise, age groups 40-70 yr stored between 60-85 and 13-38% more heat than age group 20-30 yr in the dry and humid conditions, respectively. These age-related differences in heat dissipation and heat storage were not paralleled by significant differences in local sweating and skin blood flow, or by differences in core temperature between groups. From a whole body perspective, combined heat and humidity impeded heat dissipation to a similar extent across age groups, but, more importantly, intermittent exercise in dry and humid heat stress conditions created a greater thermoregulatory challenge for middle-aged and older adults. Copyright © 2014 the American Physiological Society.

  18. Novel Anthropometry-Based Calculation of the Body Heat Capacity in the Korean Population.

    Directory of Open Access Journals (Sweden)

    Duong Duc Pham

    Full Text Available Heat capacity (HC has an important role in the temperature regulation process, particularly in dealing with the heat load. The actual measurement of the body HC is complicated and is generally estimated by body-composition-specific data. This study compared the previously known HC estimating equations and sought how to define HC using simple anthropometric indices such as weight and body surface area (BSA in the Korean population. Six hundred participants were randomly selected from a pool of 902 healthy volunteers aged 20 to 70 years for the training set. The remaining 302 participants were used for the test set. Body composition analysis using multi-frequency bioelectrical impedance analysis was used to access body components including body fat, water, protein, and mineral mass. Four different HCs were calculated and compared using a weight-based HC (HC_Eq1, two HCs estimated from fat and fat-free mass (HC_Eq2 and HC_Eq3, and an HC calculated from fat, protein, water, and mineral mass (HC_Eq4. HC_Eq1 generally produced a larger HC than the other HC equations and had a poorer correlation with the other HC equations. HC equations using body composition data were well-correlated to each other. If HC estimated with HC_Eq4 was regarded as a standard, interestingly, the BSA and weight independently contributed to the variation of HC. The model composed of weight, BSA, and gender was able to predict more than a 99% variation of HC_Eq4. Validation analysis on the test set showed a very high satisfactory level of the predictive model. In conclusion, our results suggest that gender, BSA, and weight are the independent factors for calculating HC. For the first time, a predictive equation based on anthropometry data was developed and this equation could be useful for estimating HC in the general Korean population without body-composition measurement.

  19. Heat capacity and monogamy relations in the mixed-three-spin XXX Heisenberg model at low temperatures

    Science.gov (United States)

    Zad, Hamid Arian; Movahhedian, Hossein

    2016-08-01

    Heat capacity of a mixed-three-spin (1/2,1,1/2) antiferromagnetic XXX Heisenberg chain is precisely investigated by use of the partition function of the system for which, spins (1,1/2) have coupling constant J1 and spins (1/2,1/2) have coupling constant J2. We verify tripartite entanglement for the model by means of the convex roof extended negativity (CREN) and concurrence as functions of temperature T, homogeneous magnetic field B and the coupling constants J1 and J2. As shown in our previous work, [H. A. Zad, Chin. Phys. B 25 (2016) 030303.] the temperature, the magnetic field and the coupling constants dependences of the heat capacity for such spin system have different behaviors for the entangled and separable states, hence, we did some useful comparisons between this quantity and negativities of its organized bipartite (sub)systems at entangled and separable states. Here, we compare the heat capacity of the mixed-three-spin (1/2,1,1/2) system with the CREN and the tripartite concurrence (as measures of the tripartite entanglement) at low temperature. Ground state phase transitions, and also, transition from ground state to some excited states are explained in detail for this system at zero temperature. Finally, we investigate the heat capacity behavior around those critical points in which these quantum phase transitions occur.

  20. Graded Reflectivity Mirror for the Solid State Heat Capacity Laser Final Report CRADA No. TC-2085-04

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, R. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Davis, J. A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-09-27

    This was a collaborative effort between The Regents of the University of California, Lawrence Livermore National Laboratory (LLNL) and the Boeing Company, to develop a Graded Reflectivity Mirror (GRM) to achieve improved near field fill and higher brightness in the far field output of LLNL’s Solid State Heat Capacity Laser (SSHCL).

  1. Heat and moisture exchange capacity of the upper respiratory tract and the effect of tracheotomy breathing on endotracheal climate

    NARCIS (Netherlands)

    Scheenstra, R.J.; Muller, S.H.; Vincent, A.; Hilgers, F.J.M.

    2011-01-01

    Background. The aim of this study was to assess the heat and moisture exchange (HME) capacity of the upper respiratory tract and the effect of tracheotomy breathing on endotracheal climate in patients with head and neck cancer. Methods. We plotted the subglottic temperature and humidity measurements

  2. HEAT AND MOISTURE EXCHANGE CAPACITY OF THE UPPER RESPIRATORY TRACT AND THE EFFECT OF TRACHEOTOMY BREATHING ON ENDOTRACHEAL CLIMATE

    NARCIS (Netherlands)

    Scheenstra, Renske J.; Muller, Sara H.; Vincent, Andrew; Hilgers, Frans J. M.

    2011-01-01

    Background. The aim of this study was to assess the heat and moisture exchange (HME) capacity of the upper respiratory tract and the effect of tracheotomy breathing on endotracheal climate in patients with head and neck cancer. Methods. We plotted the subglottic temperature and humidity measurements

  3. Sporulation environment of emetic toxin-producing Bacillus cereus strains determines spore size, heat resistance and germination capacity

    NARCIS (Netherlands)

    Voort, van der M.; Abee, T.

    2013-01-01

    Aim Heat resistance, germination and outgrowth capacity of Bacillus cereus spores in processed foods are major factors in causing the emetic type of gastrointestinal disease. In this study, we aim to identify the impact of different sporulation conditions on spore properties of emetic

  4. Determination of heat capacity of ionic liquid based nanofluids using group method of data handling technique

    Science.gov (United States)

    Sadi, Maryam

    2017-07-01

    In this study a group method of data handling model has been successfully developed to predict heat capacity of ionic liquid based nanofluids by considering reduced temperature, acentric factor and molecular weight of ionic liquids, and nanoparticle concentration as input parameters. In order to accomplish modeling, 528 experimental data points extracted from the literature have been divided into training and testing subsets. The training set has been used to predict model coefficients and the testing set has been applied for model validation. The ability and accuracy of developed model, has been evaluated by comparison of model predictions with experimental values using different statistical parameters such as coefficient of determination, mean square error and mean absolute percentage error. The mean absolute percentage error of developed model for training and testing sets are 1.38% and 1.66%, respectively, which indicate excellent agreement between model predictions and experimental data. Also, the results estimated by the developed GMDH model exhibit a higher accuracy when compared to the available theoretical correlations.

  5. A role for haemolymph oxygen capacity in heat tolerance of eurythermal crabs.

    Directory of Open Access Journals (Sweden)

    Folco eGiomi

    2013-05-01

    Full Text Available Heat tolerance in aquatic ectotherms is constrained by a mismatch, occurring at high temperatures, between oxygen delivery and demand which compromises the maintenance of aerobic scope. The present study analyses how the wide thermal tolerance range of an eurythermal model species, the green crab Carcinus maenas is supported and limited by its ability to sustain efficient oxygen transport to tissues. Similar to other eurytherms, C. maenas sustains naturally occurring acute warming events through the integrated response of circulatory and respiratory systems. The response of C. maenas to warming is characterized by two phases. During initial warming, oxygen consumption and heart rate increase while stroke volume and haemolymph oxygen partial pressures decrease. During further warming, dissolved oxygen levels in the venous compartment decrease below the threshold of full haemocyanin oxygen saturation. The progressive release of haemocyanin bound oxygen with further warming follows an exponential pattern, thereby saving energy in oxygen transport and causing an associated leveling off of metabolic rate. According to the concept of oxygen and capacity limited thermal tolerance, this indicates that the thermal tolerance window is widened by the increasing contribution of haemocyanin oxygen transport and associated energy savings in cardiocirculation. Haemocyanin bound oxygen sustains cardiac performance to cover the temperature range experienced by C. maenas in the field. To our knowledge this is the first study providing evidence of a relationship between thermal tolerance and blood (haemolymph oxygen transport in eurythermal invertebrates.

  6. The Stone-Wales transformation: from fullerenes to graphite, from radiation damage to heat capacity.

    Science.gov (United States)

    Heggie, M I; Haffenden, G L; Latham, C D; Trevethan, T

    2016-09-13

    The Stone-Wales (SW) transformation, or carbon-bond rotation, has been fundamental to understanding fullerene growth and stability, and ab initio calculations show it to be a high-energy process. The nature and topology of the fullerene energy landscape shows how the Ih-C60 must be the final product, if SW transformations are fast enough, and various mechanisms for their catalysis have been proposed. We review SW transformations in fullerenes and then discuss the analogous transformation in graphite, where they form the Dienes defect, originally posited to be a transition state in the direct exchange of a bonded atom pair. On the basis of density functional theory calculations in the local density approximation, we propose that non-equilibrium concentrations of the Dienes defect arising from displacing radiation are rapidly healed by point defects and that equilibrium concentrations of Dienes defects are responsible for the divergent ultra-high-temperature heat capacity of graphite.This article is part of the themed issue 'Fullerenes: past, present and future, celebrating the 30th anniversary of Buckminster Fullerene'. © 2016 The Author(s).

  7. Heat capacity changes associated with guanine quadruplex formation: an isothermal titration calorimetry study.

    Science.gov (United States)

    Majhi, Pinaki R; Qi, Jianying; Tang, Chung-Fei; Shafer, Richard H

    2008-04-01

    This study addresses the temperature dependence of the enthalpy of formation for several unimolecular quadruplexes in the presence of excess monovalent salt. We examined a series of biologically significant guanine-rich DNA sequences: thrombin binding aptamer (TBA) (d(G(2)T(2)G(2)TGTG(2)T(2)G(2)), PS2.M, a catalytically active aptamer (d(GTG(3)TAG(3)CG(3)T(2)G(2))), and the human telomere repeat (HT) (d(AG(3)(T(2)AG(3))(3))). Using CD spectra and UV melting, we confirmed the presence of quadruplex structures and established the temperature range in which quadruplex conformation is stable. We then performed ITC experiments, adding DNA to a solution containing excess NaCl or KCl. In this approach, only several additions are made, and only the enthalpy of quadruplex formation is measured. This measurement was repeated at different temperatures to determine the temperature dependence of the enthalpy change accompanying quadruplex formation. To control for the effect of nonspecific salt interactions during DNA folding, we repeated the experiment by replacing the quadruplex-forming sequences with a similar but nonfolding sequence. Dilution enthalpies were also subtracted to obtain the final enthalpy value involving only the quadruplex folding process. For all sequences studied, quadruplex formation was exothermic but with an increasing magnitude with increasing temperature. These results are discussed in terms of the change in heat capacity associated with quadruplex formation.

  8. Simultaneous measurement of thermal conductivity and heat capacity by flash thermal imaging methods

    Science.gov (United States)

    Tao, N.; Li, X. L.; Sun, J. G.

    2017-06-01

    Thermal properties are important for material applications involved with temperature. Although many measurement methods are available, they may not be convenient to use or have not been demonstrated suitable for testing of a wide range of materials. To address this issue, we developed a new method for the nondestructive measurement of the thermal effusivity of bulk materials with uniform property. This method is based on the pulsed thermal imaging-multilayer analysis (PTI-MLA) method that has been commonly used for testing of coating materials. Because the test sample for PTI-MLA has to be in a two-layer configuration, we have found a commonly used commercial tape to construct such test samples with the tape as the first-layer material and the bulk material as the substrate. This method was evaluated for testing of six selected solid materials with a wide range of thermal properties covering most engineering materials. To determine both thermal conductivity and heat capacity, we also measured the thermal diffusivity of these six materials by the well-established flash method using the same experimental instruments with a different system setup. This paper provides a description of these methods, presents detailed experimental tests and data analyses, and discusses measurement results and their comparison with literature values.

  9. Low temperature resonances in the fermion heat capacity of finite systems

    Energy Technology Data Exchange (ETDEWEB)

    Kuzmenko, N K [V.G. Khlopin Radium Institute, 194021 St.-Petersburg (Russian Federation); Mikhajlov, V M [Institute of Physics St.-Petersburg State University 198904 (Russian Federation)], E-mail: kuzmenko@NK9433.spb.edu

    2009-02-01

    Temperature variations of the heat capacity (C) are studied in a low temperature regime T < {epsilon}{sub f}/N ({epsilon}{sub f} is the Fermi energy) for 2D-, and 3D-systems with N{approx} 10{sup 2} to 10{sup 4} treated as a canonical ensemble of N-noninteracting fermions. The analysis of C is performed by introducing a function {rho}({epsilon}), the spectral distribution of C that gives the contribution of each single-particle state to C. The function {rho}({epsilon}) has two peaks divided by the energy interval {delta} {epsilon} {approx} (2 to 5) T. If at some temperature T{sub res} there takes place a resonance i.e. the positions of these peaks coincide with energies of two levels nearest to {epsilon}{sub F} then C vs T shows a local maximum i.e. T{sub res} is determined by single-particle level spacings near the Fermi level.

  10. Army Solid State Laser Program: Design, Operation, and Mission Analysis for a Heat-Capacity Laser

    Energy Technology Data Exchange (ETDEWEB)

    Dane, C B; Flath, L; Rotter, M; Fochs, S; Brase, J; Bretney, K

    2001-05-18

    Solid-state lasers have held great promise for the generation of high-average-power, high-quality output beams for a number of decades. However, the inherent difficulty of scaling the active solid-state gain media while continuing to provide efficient cooling has limited demonstrated powers to <5kW. Even at the maximum demonstrated average powers, the output is most often delivered as continuous wave (CW) or as small energy pulses at high pulse repetition frequency (PRF) and the beam divergence is typically >10X the diffraction limit. Challenges posed by optical distortions and depolarization arising from internal temperature gradients in the gain medium of a continuously cooled system are only increased for laser designs that would attempt to deliver the high average power in the form of high energy pulses (>25J) from a single coherent optical aperture. Although demonstrated phase-locking of multiple laser apertures may hold significant promise for the future scaling of solid-state laser systems,1 the continuing need for additional technical development and innovation coupled with the anticipated complexity of these systems effectively limits this approach for near-term multi-kW laser operation outside of a laboratory setting. We have developed and demonstrated a new operational mode for solid-state laser systems in which the cooling of the gain medium is separated in time from the lasing cycle. In ''heat-capacity'' operation, no cooling takes place during lasing. The gain medium is pumped very uniformly and the waste heat from the excitation process is stored in the solid-state gain medium. By depositing the heat on time scales that are short compared to thermal diffusion across the optical aperture, very high average power operation is possible while maintaining low optical distortions. After a lasing cycle, aggressive cooling can then take place in the absence of lasing, limited only by the fracture limit of the solid-state medium. This mode

  11. Application of customized absorption heat pumps with heating capacities above 500 kW: Project: VIVO, Warngau (near Munich)

    OpenAIRE

    Zachmeier, Peter; Radspieler, Michael; Schweigler, Christian

    2013-01-01

    Part of: Thermally driven heat pumps for heating and cooling. – Ed.: Annett Kühn – Berlin: Universitätsverlag der TU Berlin, 2013 ISBN 978-3-7983-2686-6 (print) ISBN 978-3-7983-2596-8 (online) urn:nbn:de:kobv:83-opus4-39458 [http://nbn-resolving.de/urn:nbn:de:kobv:83-opus4-39458] In 2005 a gas fired single effect absorption heat pump was installed at the area of VIVO GmbH, who runs a local civic waste collection point. Besides other recyclable materials, biodegra...

  12. Thermal expansion and the heat capacity of nanocrystalline and coarse-crystalline silver sulfide Ag2S

    Science.gov (United States)

    Sadovnikov, S. I.; Gusev, A. I.

    2017-09-01

    The thermal expansion and the heat capacity of coarse-crystalline and nanocrystalline silver sulfide Ag2S were studied by dilatometry and differential scanning calorimentry for the first time in the temperature range 290-970 K. It is found that the thermal expansion coefficient and the heat capacity of nanocrystalline silver sulfide in this temperature range are higher than those in the case of the coarse-crystalline sulfide. It is revealed that the transformation of α-Ag2S acanthite to β-Ag2S argentite and β-Ag2S argentite to γ-Ag2S phase are the first-order phase transitions; the temperatures and the enthalpies of these transformations have been determined.

  13. Bias induced modulation of electrical and thermal conductivity and heat capacity of BN and BN/graphene bilayers

    Science.gov (United States)

    Chegel, Raad

    2017-04-01

    By using the tight binding approximation and Green function method, the electronic structure, density of state, electrical conductivity, heat capacity of BN and BN/graphene bilayers are investigated. The AA-, AB1- and AB2- BN/graphene bilayers have small gap unlike to BN bilayers which are wide band gap semiconductors. Unlike to BN bilayer, the energy gap of graphene/BN bilayers increases with external field. The magnitude of the change in the band gap of BN bilayers is much higher than the graphene/BN bilayers. Near absolute zero, the σ(T) is zero for BN bilayers and it increases with temperature until reaches maximum value then decreases. The BN/graphene bilayers have larger electrical conductivity larger than BN bilayers. For both bilayers, the specific heat capacity has a Schottky anomaly.

  14. Calculation of thermal conductivity, thermal diffusivity and specific heat capacity of sedimentary rocks using petrophysical well logs

    DEFF Research Database (Denmark)

    Fuchs, Sven; Balling, Niels; Förster, Andrea

    2015-01-01

    In this study, equations are developed that predict for synthetic sedimentary rocks (clastics, carbonates and evapourates) thermal properties comprising thermal conductivity, specific heat capacity and thermal diffusivity. The rock groups are composed of mineral assemblages with variable contents...... of each property vary depending on the selected well-log combination. Best prediction is in the range of 2–8 per cent for the specific heat capacity, of 5–10 per cent for the thermal conductivity, and of 8–15 for the thermal diffusivity, respectively. Well-log derived thermal conductivity is validated...... by laboratory data measured on cores from deep boreholes of the Danish Basin, the North German Basin, and the Molasse Basin. Additional validation of thermal conductivity was performed by comparing predicted and measured temperature logs. The maximum deviation between these logs is conductivity...

  15. Bias induced modulation of electrical and thermal conductivity and heat capacity of BN and BN/graphene bilayers

    Energy Technology Data Exchange (ETDEWEB)

    Chegel, Raad, E-mail: Raad.chegel@gmail.com

    2017-04-15

    By using the tight binding approximation and Green function method, the electronic structure, density of state, electrical conductivity, heat capacity of BN and BN/graphene bilayers are investigated. The AA-, AB{sub 1}- and AB{sub 2}- BN/graphene bilayers have small gap unlike to BN bilayers which are wide band gap semiconductors. Unlike to BN bilayer, the energy gap of graphene/BN bilayers increases with external field. The magnitude of the change in the band gap of BN bilayers is much higher than the graphene/BN bilayers. Near absolute zero, the σ(T) is zero for BN bilayers and it increases with temperature until reaches maximum value then decreases. The BN/graphene bilayers have larger electrical conductivity larger than BN bilayers. For both bilayers, the specific heat capacity has a Schottky anomaly.

  16. Laser Measurement of the Speed of Sound in Gases: A Novel Approach to Determining Heat Capacity Ratios and Gas Composition

    Science.gov (United States)

    Baum, J. Clayton; Compton, R. N.; Feigerle, Charles S.

    2008-01-01

    The speed of sound is measured in several gases using a pulsed laser to create a micro-spark on a carbon rod and a microphone connected to a digital oscilloscope to measure the time-of-flight of the resulting shockwave over a known distance. These data are used to calculate the heat capacity ratios (C[subscript p]/C[subscript V]) of the gases and…

  17. Magneto-heat capacity study on Kondo lattice system Ce(Ni1−xCux ...

    Indian Academy of Sciences (India)

    Abstract. Heat capacity studies on the Kondo lattice system Ce(Ni1−xCux)2Al3, in the presence of magnetic fields, were reported for x = 0.0−0.4. The physical properties of the intermediate compositions like x = 0.3 and 0.4 were known for their enhanced thermoelectric power and hence have been analysed with an extra ...

  18. Native and Heated Hydrolysates of Milk Proteins and Their Capacity to Inhibit Lipid Peroxidation in the Zebrafish Larvae Model.

    Science.gov (United States)

    Carrillo, Wilman; Guzmán, Xavier; Vilcacundo, Edgar

    2017-09-14

    Casein and whey proteins with and without heat treatment were obtained of whole milk and four commercial milks in Ecuador, and were hydrolyzed. Then, their capacity to inhibit the lipid peroxidation using the TBARS method was evaluated at concentrations of 0.02, 0.04, 0.2, and, 0.4 mg/mL. Native and heated hydrolysates of milk proteins present high inhibitions of lipid peroxidation with a dose dependent effect both in vivo and in vitro tests. Casein and whey proteins obtained from whole milk were the ones with the highest anti-oxidant activity in vitro and in vivo test. Native casein hydrolysate at 0.4 mg/mL present a value of 55.55% of inhibition of lipid peroxidation and heated casein hydrolysate at 0.4 mg/mL presents a value of 58.00% of inhibition of lipid peroxidation. Native whey protein at 0.4 mg/mL present a value of 34.84% of inhibition of lipid peroxidation, and heated whey protein at 0.4 mg/mL presents a value of 40.86% of inhibition of lipid peroxidation. Native and heated casein hydrolysates were more active than native and heated whey protein hydrolysates. Heat treatments have an effect of increasing the in vitro inhibition of lipid peroxidation of hydrolysates of milk protein. Casein and whey hydrolysates were able to inhibiting lipid peroxidation in the zebrafish larvae model. Native casein hydrolysate obtained of whole milk presents 48.35% of inhibition TBARS in vivo, this activity was higher in heated casein hydrolysate obtained of whole milk with a value of 56.28% of inhibition TBARS in vivo. Native whey protein hydrolysate obtained of whole milk presents 35.30% of inhibition TBARS, and heated whey protein hydrolysate obtained of whole milk was higher, with a value of 43.60% of inhibition TBARS in vivo.

  19. A study on specific heat capacities of Li-ion cell components and their influence on thermal management

    Science.gov (United States)

    Loges, André; Herberger, Sabrina; Seegert, Philipp; Wetzel, Thomas

    2016-12-01

    Thermal models of Li-ion cells on various geometrical scales and with various complexity have been developed in the past to account for the temperature dependent behaviour of Li-ion cells. These models require accurate data on thermal material properties to offer reliable validation and interpretation of the results. In this context a thorough study on the specific heat capacities of Li-ion cells starting from raw materials and electrode coatings to representative unit cells of jelly rolls/electrode stacks with lumped values was conducted. The specific heat capacity is reported as a function of temperature and state of charge (SOC). Seven Li-ion cells from different manufactures with different cell chemistry, application and design were considered and generally applicable correlations were developed. A 2D thermal model of an automotive Li-ion cell for plug-in hybrid electric vehicle (PHEV) application illustrates the influence of specific heat capacity on the effectivity of cooling concepts and the temperature development of Li-ion cells.

  20. Heat capacity, lattice dynamics, and thermodynamic stability of the negative thermal expansion material HfMo2O8

    Science.gov (United States)

    Kennedy, Catherine A.; White, Mary Anne; Wilkinson, Angus P.; Varga, Tamas

    2007-06-01

    We explore the lattice dynamics of the negative thermal expansion material, cubic HfMo2O8 , through analysis of its heat capacity (measured from 0.5to300K ) and its room-temperature Raman spectrum. Its heat capacity is quantitatively very similar to that of ZrW2O8 , as is its Raman spectrum. The heat capacity of HfMo2O8 can be well represented by the present lattice dynamical assignment and by CP(HfW2O8)-CP(ZrW2O8)+CP(ZrMo2O8) , but not by CP(HfO2)+2CP(MoO3) , likely because the AB2O8 compounds have low-frequency optic modes, not present in HfO2 and MoO3 . The present thermodynamic data also allow an analysis of the thermodynamic stability of cubic HfMo2O8 , and it is shown to be unstable with respect to MoO3 and HfO2 at room temperature.

  1. The determination of values of the specific heat capacity of the selected thermal insulation materials used in track bed structure

    Directory of Open Access Journals (Sweden)

    Dobeš Peter

    2017-01-01

    Full Text Available The report concentrates on the determination of the specific heat capacity of the selected thermal insulation materials (liapor, styrodur, foam concrete. The aim of the report is to gain the necessary input parameters for the numerical modelling of the temperature changes of various track bed structures of the railway line where a part or, if appropriate, the whole protective layer is replaced by the material with better thermal insulation properties. There are described the methods for stating the specific heat capacity as well as the calibration of the calorimeter for stating of the calorimetric constant in the introduction of the report. The parameters needed for calculation of the specific heat capacity of the selected thermal insulation materials are characterized in the second part of the report. There are also introduced the laboratory stated values of the parameter in question. The comparison of the values stated by the laboratory measurements with the values introduced in the technical data sheets from their producers (or if appropriate gained from the foreign sources is made in the conclusion of the report.

  2. Heat-capacity changes in host-guest complexation by Coulomb interactions in aqueous solution.

    Science.gov (United States)

    Kano, Koji; Ishida, Yoshiyuki; Kitagawa, Kohei; Yasuda, Mayuko; Watanabe, Maki

    2007-10-01

    Heat-capacity changes (deltaC(p)0) were determined for the complexation of 1-alkanecarboxylates with protonated hexakis(6-amino-6-deoxy)-alpha-cyclodextrin (per-NH3(+)-alpha-CD) and heptakis(6-amino-6-deoxy)-beta-cyclodextrin (per-NH3(+)-beta-CD). DeltaC(p)0 decreased with an increase in the binding constant (K) and plateaued at K = 4000 M(-1). The complexes of 1-pentanoate, 1-hexanoate, and 1-heptanoate with per-NH3(+)-alpha-CD are classified as the host-guest system in which the size of the guest fits the CD cavity well. In such a system, van der Waals interaction is the major force for complexation, leading to a negative deltaH0 value. Simultaneously, the water molecules around the hydrophobic alkyl chain of the guest and inside the CD cavity are released to the aqueous bulk phase, leading to a positive deltaS0 value. The negative deltaC(p)0 value in such complexation is ascribed to dehydration of the hydrophobic alkyl chain of the guest and extrusion of the water molecules inside the CD cavity. Meanwhile, the complexes that show positive deltaC(p)0 values are characterized by complexation in which the guest molecules are significantly smaller than the CD cavities. In such a case, the complexation is endothermic and driven by the entropy gain. When the guest is much smaller than the CD cavity, the main binding force should be Coulomb interaction. To form an ionic bond, dehydration of the charged groups must occur. This process is endothermic and leads to positive deltaH0 and deltaS0 values. As the top of the CD cavity is capped by a small but hydrophobic alkyl chain, the water molecules inside the CD cavity may form the iceberg structure. This process must be accompanied by a positive deltaC(p)0 value. Hence, the complexation of a small guest with the CD with a large cavity through Coulomb interactions shows positive and large deltaC(p)0 values. These conclusions were applied to the electrostatic binding of proteins with an anionic ligand.

  3. Multiple pulse-heating experiments with different current to determine total emissivity, heat capacity, and electrical resistivity of electrically conductive materials at high temperatures

    Science.gov (United States)

    Watanabe, Hiromichi; Yamashita, Yuichiro

    2012-01-01

    A modified pulse-heating method is proposed to improve the accuracy of measurement of the hemispherical total emissivity, specific heat capacity, and electrical resistivity of electrically conductive materials at high temperatures. The proposed method is based on the analysis of a series of rapid resistive self-heating experiments on a sample heated at different temperature rates. The method is used to measure the three properties of the IG-110 grade of isotropic graphite at temperatures from 850 to 1800 K. The problem of the extrinsic heating-rate effect, which reduces the accuracy of the measurements, is successfully mitigated by compensating for the generally neglected experimental error associated with the electrical measurands (current and voltage). The results obtained by the proposed method can be validated by the linearity of measured quantities used in the property determinations. The results are in reasonably good agreement with previously published data, which demonstrate the suitability of the proposed method, in particular, to the resistivity and total emissivity measurements. An interesting result is the existence of a minimum in the emissivity of the isotropic graphite at around 1120 K, consistent with the electrical resistivity results.

  4. Thermoeconomic Evaluation of Modular Organic Rankine Cycles for Waste Heat Recovery over a Broad Range of Heat Source Temperatures and Capacities

    Directory of Open Access Journals (Sweden)

    Markus Preißinger

    2017-02-01

    Full Text Available Industrial waste heat recovery by means of an Organic Rankine Cycle (ORC can contribute to the reduction of CO2 emissions from industries. Before market penetration, high efficiency modular concepts have to be developed to achieve appropriate economic value for industrial decision makers. This paper aims to investigate modularly designed ORC systems from a thermoeconomic point of view. The main goal is a recommendation for a suitable chemical class of working fluids, preferable ORC design and a range of heat source temperatures and thermal capacities in which modular ORCs can be economically feasible. For this purpose, a thermoeconomic model has been developed which is based on size and complexity parameters of the ORC components. Special emphasis has been laid on the turbine model. The paper reveals that alkylbenzenes lead to higher exergetic efficiencies compared to alkanes and siloxanes. However, based on the thermoeconomic model, the payback periods of the chemical classes are almost identical. With the ORC design, the developed model and the boundary conditions of this study, hexamethyldisiloxane is a suitable working fluid and leads to a payback period of less than 5 years for a heat source temperature of 400 to 600 °C and a mass flow rate of the gaseous waste heat stream of more than 4 kg/s.

  5. Ice ingestion with a long rest interval increases the endurance exercise capacity and reduces the core temperature in the heat.

    Science.gov (United States)

    Naito, Takashi; Iribe, Yuka; Ogaki, Tetsuro

    2017-01-05

    The timing in which ice before exercise should be ingested plays an important role in optimizing its success. However, the effects of differences in the timing of ice ingestion before exercise on cycling capacity, and thermoregulation has not been studied. The aim of the present study was to assess the effect of length of time after ice ingestion on endurance exercise capacity in the heat. Seven males ingested 1.25 g kg body mass-1 of ice (0.5 °C) or cold water (4 °C) every 5 min, six times. Under three separate conditions after ice or water ingestion ([1] taking 20 min rest after ice ingestion, [2] taking 5 min rest after ice ingestion, and [3] taking 5 min rest after cold water ingestion), seven physically active male cyclists exercised at 65% of their maximal oxygen uptake to exhaustion in the heat (35 °C, 30% relative humidity). Participants cycled significantly longer following both ice ingestion with a long rest interval (46.0 ± 7.7 min) and that with a short rest interval (38.7 ± 5.7 min) than cold water ingestion (32.3 ± 3.2 min; both p Heat storage under condition of ice ingestion with a long rest interval during the pre-exercise period was significantly lower than that observed with a short rest interval (-4.98 ± 2.50 W m-2; p heat, which is suggested to be driven by a reduced rectal temperature and heat storage before the start of exercise.

  6. Effects of caffeine on endurance capacity and psychological state in young females and males exercising in the heat.

    Science.gov (United States)

    Suvi, Silva; Timpmann, Saima; Tamm, Maria; Aedma, Martin; Kreegipuu, Kairi; Ööpik, Vahur

    2017-01-01

    Acute caffeine ingestion is considered effective in improving endurance capacity and psychological state. However, current knowledge is based on the findings of studies that have been conducted on male subjects mainly in temperate environmental conditions, but some physiological and psychological effects of caffeine differ between the sexes. The purpose of this study was to compare the physical performance and psychological effects of caffeine in young women and men exercising in the heat. Thirteen male and 10 female students completed 2 constant-load walks (60% of thermoneutral peak oxygen consumption on a treadmill until volitional exhaustion) in a hot-dry environment (air temperature, 42 °C; relative humidity, 20%) after caffeine (6 mg·kg -1 ) and placebo (wheat flour) ingestion in a double-blind, randomly assigned, crossover manner. Caffeine, compared with placebo, induced greater increases (p Caffeine decreased (p caffeine was associated with a shorter time to exhaustion. In conclusion, acute caffeine ingestion increases HR and blood lactate levels during exercise in the heat, but it has no impact on thermoregulation or endurance capacity in either gender. Under exercise-heat stress, caffeine reduces ratings of perceived exertion and fatigue in males but not in females.

  7. IMP improves water-holding capacity, physical and sensory properties of heat-induced gels from porcine meat.

    Science.gov (United States)

    Nakamura, Yukinobu; Migita, Koshiro; Okitani, Akihiro; Matsuishi, Masanori

    2014-05-01

    Water-holding capacity (WHC) of heat-induced pork gels was examined. The heat-induced gels were obtained from meat homogenates prepared by adding nine volumes of 0.3-0.5 mol/L NaCl solutions containing 9-36 mmol/L disodium inosine-5'-monophosphate (IMP) or 9 mmol/L tetrapotassium pyrophosphate (KPP) to minced pork. IMP at 36 mmol/L enhanced the WHC to the same level as attained by KPP. Physical and sensory properties of heat-induced gels were also examined. The heat-induced gels were prepared from porcine meat homogenates containing 0.3 mol/L NaCl and 9-36 mmol/L IMP or 9 mmol/L KPP. IMP at 36 mmol/L enhanced the values of hardness, cohesiveness, gumminess and springiness, measured with a Tensipresser, and several organoleptic scores to the same level as the score attained by KPP. Thus, it is concluded that IMP is expected to be a practical substitute for pyrophosphates to improve the quality of sausages. © 2014 Japanese Society of Animal Science.

  8. FEM Simulation of the Effect of Coefficient of Thermal Expansion and Heat Capacity on Prediction of Residual Stresses of Compression Molded Glass Lenses

    Science.gov (United States)

    Tao, Bo; Yuan, Ye

    2017-11-01

    In this research, the effects of the coefficient of thermal expansion (CTE) and heat capacity on the prediction of residual stresses in BK7 compression molded glass lenses were studied. Three different groups of CTE and two different kinds of heat capacity, which are constant and proportional to temperature, were chosen to investigate the impacts of residual stresses. The simulation results show a big difference and suggest that the properties of glass materials determine the residual stresses and should be measured carefully.

  9. Labworks and the Kundt's Tube: A New Way to Determine the Heat Capacities of Gases

    Science.gov (United States)

    Bryant, Philip A.; Morgan, Matthew E.

    2004-01-01

    The potency of heat in gases is measured by the application of a computer and the LabWorks interaction, while the speed of sound in gases is determined by an instrument called Kundt's tube. This unique and accurate procedure is repeatable, and greatly reduces data acquisition time.

  10. Using heat demand prediction to optimise Virtual Power Plant production capacity

    NARCIS (Netherlands)

    Bakker, Vincent; Molderink, Albert; Hurink, Johann L.; Smit, Gerardus Johannes Maria

    2008-01-01

    In the coming decade a strong trend towards distributed electricity generation (microgeneration) is expected. Micro-generators are small appliances that generate electricity (and heat) at the kilowatt level, which allows them to be installed in households. By combining a group of micro-generators, a

  11. Low-temperature heat capacities and Raman spectra of negative thermal expansion compounds ZrW2O8 and HfW2O8

    Science.gov (United States)

    Yamamura, Yasuhisa; Nakajima, Noriyuki; Tsuji, Toshihide; Koyano, Mikio; Iwasa, Yoshihiro; Katayama, Shin'ichi; Saito, Kazuya; Sorai, Michio

    2002-06-01

    Heat capacities of ZrW2O8 and HfW2O8 were precisely measured between 1.8 and 330 K. Heat-capacity curves of ZrW2O8 and HfW2O8 are very similar to each other. The heat capacity of HfW2O8 at low temperature is larger than that of ZrW2O8 due to atomic mass effect, but both heat capacities cross around 220 K. Raman spectra of ZrW2O8 and HfW2O8 were recorded at room temperature. Frequency distributions of lattice vibrations were estimated through an analysis of the heat capacities for ZrW2O8 and HfW2O8. It is found that the difference in the frequency distributions between ZrW2O8 and HfW2O8 arises from the different atomic mass and bond strength, and causes the different temperature dependence of the heat capacities. The properties of the optical-phonon modes with a large negative mode-Grüneisen parameter are discussed.

  12. Effect of high energy electron beam (10MeV) on specific heat capacity of low-density polyethylene/hydroxyapatite nano-composite.

    Science.gov (United States)

    Soltani, Z; Ziaie, F; Ghaffari, M; Beigzadeh, A M

    2017-02-01

    In the present work, thermal properties of low density polyethylene (LDPE) and its nano composites are investigated. For this purpose LDPE reinforced with different weight percents of hydroxyapatite (HAP) powder which was synthesized via hydrolysis method are produced. The samples were irradiated with 10MeV electron beam at doses of 75 to 250kGy. Specific heat capacity measurement have been carried out at different temperatures, i.e. 25, 50, 75 and 100°C using modulated temperature differential scanning calorimetry (MTDSC) apparatus and the effect of three parameters include of temperature, irradiation dose and the amount of HAP nano particles as additives on the specific heat capacity of PE/HAP have been investigated precisely. The MTDSC results indicate that the specific heat capacity have decreased by addition of nano sized HAP as reinforcement for LDPE. On the other hand, the effect of radiation dose is reduction in the specific heat capacity in all materials including LDPE and its nano composites. The HAP nano particles along with cross-link junctions due to radiation restrain the movement of the polymer chains in the vicinity of each particle and improve the immobility of polymer chains and consequently lead to reduction in specific heat capacity. Also, the obtained results confirm that the radiation effect on the specific heat capacity is more efficient than the reinforcing effect of nano-sized hydroxyapatite. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Size-dependence of the heat capacity and thermodynamic properties of hematite ({alpha}-Fe{sub 2}O{sub 3})

    Energy Technology Data Exchange (ETDEWEB)

    Snow, Claine L.; Lee, Christopher R.; Shi, Quan; Boerio-Goates, Juliana [Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT 84602 (United States); Woodfield, Brian F., E-mail: brian_woodfield@byu.ed [Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT 84602 (United States)

    2010-09-15

    The heat capacity of a 13 nm hematite ({alpha}-Fe{sub 2}O{sub 3}) sample was measured from T = (1.5 to 350) K using a combination of semi-adiabatic and adiabatic calorimetry. The heat capacity was higher than that of the bulk which can be attributed to the presence of water on the surface of the nanoparticles. No anomaly was observed in the heat capacity due to the Morin transition and theoretical fits of the heat capacity below T = 15 K show a small T{sup 3} dependence (due to lattice contributions) with no T{sup 3/2} dependence. This suggests that there are no magnetic spin-wave contributions to the heat capacity of 13 nm hematite. The use of a large linear term to fit the heat capacity below T = 15 K is most likely due to superparamagnetic contributions. A small anomaly within the temperature range (4 to 8) K was attributed to the presence of uncompensated surface spins.

  14. Small heat-shock proteins and leaf cooling capacity account for the unusual heat tolerance of the central spike leaves in Agave tequilana var. Weber.

    Science.gov (United States)

    Luján, Rosario; Lledías, Fernando; Martínez, Luz María; Barreto, Rita; Cassab, Gladys I; Nieto-Sotelo, Jorge

    2009-12-01

    Agaves are perennial crassulacean acid metabolism (CAM) plants distributed in tropical and subtropical arid environments, features that are attractive for studying the heat-shock response. In agaves, the stress response can be analysed easily during leaf development, as they form a spirally shaped rosette, having the meristem surrounded by folded leaves in the centre (spike) and the unfolded and more mature leaves in the periphery. Here, we report that the spike of Agave tequilana is the most thermotolerant part of the rosette withstanding shocks of up to 55 degrees C. This finding was inconsistent with the patterns of heat-shock protein (Hsp) gene expression, as maximal accumulation of Hsp transcripts was at 44 degrees C in all sectors (spike, inner, middle and outer). However, levels of small HSP (sHSP)-CI and sHSP-CII proteins were conspicuously higher in spike leaves at all temperatures correlating with their thermotolerance. In addition, spike leaves showed a higher stomatal density and abated more efficiently their temperature several degrees below that of air. We propose that the greater capacity for leaf cooling during the day in response to heat stress, and the elevated levels of sHSPs, constitute part of a set of strategies that protect the SAM and folded leaves of A. tequilana from high temperatures.

  15. Analysis of the Storage Capacity in an Aggregated Heat Pump Portfolio

    DEFF Research Database (Denmark)

    Nielsen, Kirsten Mølgaard; Andersen, Palle; Pedersen, Tom Søndergård

    2015-01-01

    to suitable time slots and this makes it possible to avoid some grid storage capacity. The energy is bought based on prediction of energy prices, weather forecast and an aggregated house model on the NORD POOL day-ahead market. The bought energy is then distributed to the houses using a model free sorting...... (scheduling) algorithm. The properties of this scheduling are investigated in the paper especially the flexibility and ability to trade on the intra-day regulating market is in focus....

  16. Molecular simulation of caloric properties of fluids modelled by force fields with intramolecular contributions: Application to heat capacities.

    Science.gov (United States)

    Smith, William R; Jirsák, Jan; Nezbeda, Ivo; Qi, Weikai

    2017-07-21

    The calculation of caloric properties such as heat capacity, Joule-Thomson coefficients, and the speed of sound by classical force-field-based molecular simulation methodology has received scant attention in the literature, particularly for systems composed of complex molecules whose force fields (FFs) are characterized by a combination of intramolecular and intermolecular terms. The calculation of a thermodynamic property for a system whose molecules are described by such a FF involves the calculation of the residual property prior to its addition to the corresponding ideal-gas property, the latter of which is separately calculated, either using thermochemical compilations or nowadays accurate quantum mechanical calculations. Although the simulation of a volumetric residual property proceeds by simply replacing the intermolecular FF in the rigid molecule case by the total (intramolecular plus intermolecular) FF, this is not the case for a caloric property. We describe the correct methodology required to perform such calculations and illustrate it in this paper for the case of the internal energy and the enthalpy and their corresponding molar heat capacities. We provide numerical results for c P , one of the most important caloric properties. We also consider approximations to the correct calculation procedure previously used in the literature and illustrate their consequences for the examples of the relatively simple molecule 2-propanol, CH 3 CH(OH)CH 3 , and for the more complex molecule monoethanolamine, HO(CH 2 ) 2 NH 2 , an important fluid used in carbon capture.

  17. Heat capacity measurements of Sr{sub 2}RuO{sub 4} under uni-axial strain

    Energy Technology Data Exchange (ETDEWEB)

    Li, You-sheng; Mackenzie, Andrew [Max Planck Institute for Chemical Physics of Solids, Dresden (Germany); University of St. Andrews, School of Physics and Astronomy (United Kingdom); Gibbs, Alexandra [Max Planck Institute for Solid State Research, Stuttgart (Germany); Hicks, Clifford [Max Planck Institute for Chemical Physics of Solids, Dresden (Germany); Nicklas, Michael [University of St. Andrews, School of Physics and Astronomy (United Kingdom)

    2016-07-01

    One of the most-discussed possible pairing symmetries of Sr{sub 2}RuO{sub 4} is p{sub x} ± ip{sub y}. By applying strain along left angle 100 right angle -direction, the degeneracy of the p{sub x} and p{sub y} components is lifted, and thus there should be two critical temperatures (T{sub c}). Hicks et al. have observed an increase of T{sub c} of Sr{sub 2}RuO{sub 4} under both compressive and tensile strains, by measuring the susceptibility, which is sensitive only to the first transition. Their results also indicate, indirectly, that any splitting of T{sub c}s might be small. For a direct test of possible splitting, we measure the heat capacity of Sr{sub 2}RuO{sub 4} under strain. To do so, we are developing an approach to measure heat capacity under non-adiabatic conditions. We have observed an increase of T{sub c} under compressive strain. This is the first thermodynamic evidence of the strain-induced increase in T{sub c} of Sr{sub 2}RuO{sub 4}.

  18. Carbohydrate ingestion and pre-cooling improves exercise capacity following soccer-specific intermittent exercise performed in the heat.

    Science.gov (United States)

    Clarke, N D; Maclaren, D P M; Reilly, T; Drust, B

    2011-07-01

    Ingestion of carbohydrate and reducing core body temperature pre-exercise, either separately or combined, may have ergogenic effects during prolonged intermittent exercise in hot conditions. The aim of this investigation was to examine the effect of carbohydrate ingestion and pre-cooling on the physiological responses to soccer-specific intermittent exercise and the impact on subsequent high-intensity exercise performance in the heat. Twelve male soccer players performed a soccer-specific intermittent protocol for 90 min in the heat (30.5°C and 42.2% r.h.) on four occasions. On two occasions, the participants underwent a pre-cooling manoeuvre. During these sessions either a carbohydrate-electrolyte solution (CHOc) or a placebo was consumed at (PLAc). During the remaining sessions either the carbohydrate-electrolyte solution (CHO) or placebo (PLA) was consumed. At 15-min intervals throughout the protocol participants performed a mental concentration test. Following the soccer-specific protocol participants performed a self-chosen pace test and a test of high-intensity exercise capacity. The period of pre-cooling significantly reduced core temperature, muscle temperature and thermal sensation (P carbohydrate during exercise enhances exercise capacity and helps maintain mental performance during intermittent exercise in hot conditions.

  19. Molecular simulation of caloric properties of fluids modelled by force fields with intramolecular contributions: Application to heat capacities

    Science.gov (United States)

    Smith, William R.; Jirsák, Jan; Nezbeda, Ivo; Qi, Weikai

    2017-07-01

    The calculation of caloric properties such as heat capacity, Joule-Thomson coefficients, and the speed of sound by classical force-field-based molecular simulation methodology has received scant attention in the literature, particularly for systems composed of complex molecules whose force fields (FFs) are characterized by a combination of intramolecular and intermolecular terms. The calculation of a thermodynamic property for a system whose molecules are described by such a FF involves the calculation of the residual property prior to its addition to the corresponding ideal-gas property, the latter of which is separately calculated, either using thermochemical compilations or nowadays accurate quantum mechanical calculations. Although the simulation of a volumetric residual property proceeds by simply replacing the intermolecular FF in the rigid molecule case by the total (intramolecular plus intermolecular) FF, this is not the case for a caloric property. We describe the correct methodology required to perform such calculations and illustrate it in this paper for the case of the internal energy and the enthalpy and their corresponding molar heat capacities. We provide numerical results for cP, one of the most important caloric properties. We also consider approximations to the correct calculation procedure previously used in the literature and illustrate their consequences for the examples of the relatively simple molecule 2-propanol, CH3CH(OH)CH3, and for the more complex molecule monoethanolamine, HO(CH2)2NH2, an important fluid used in carbon capture.

  20. Heat capacity peak at the quantum critical point of the transverse Ising magnet CoNb2O6.

    Science.gov (United States)

    Liang, Tian; Koohpayeh, S M; Krizan, J W; McQueen, T M; Cava, R J; Ong, N P

    2015-07-06

    The transverse Ising magnet Hamiltonian describing the Ising chain in a transverse magnetic field is the archetypal example of a system that undergoes a transition at a quantum critical point (QCP). The columbite CoNb2O6 is the closest realization of the transverse Ising magnet found to date. At low temperatures, neutron diffraction has observed a set of discrete collective spin modes near the QCP. Here, we ask if there are low-lying spin excitations distinct from these relatively high-energy modes. Using the heat capacity, we show that a significant band of gapless spin excitations exists. At the QCP, their spin entropy rises to a prominent peak that accounts for 30% of the total spin degrees of freedom. In a narrow field interval below the QCP, the gapless excitations display a fermion-like, temperature-linear heat capacity below 1 K. These novel gapless modes are the main spin excitations participating in, and affected by, the quantum transition.

  1. Calibration of a low temperature calorimeter and application in the determination of isobaric heat capacity of 2-propanol

    Energy Technology Data Exchange (ETDEWEB)

    Casas, L.M., E-mail: lmcasas@uvigo.es [Departamento de Fisica Aplicada, Facultade de Ciencias Experimentais, Universidade de Vigo, Lagoas Marcosende s/n, 36310 Vigo (Spain); Plantier, F. [Laboratoire de Thermodynamique et Energetique des Fluides Complexes - UMR 5150, Universite de Pau et des Pays de l' Adour, BP 1155, 64013 Pau (France); Pineiro, M.M.; Legido, J.L. [Departamento de Fisica Aplicada, Facultade de Ciencias Experimentais, Universidade de Vigo, Lagoas Marcosende s/n, 36310 Vigo (Spain); Bessieres, D. [Laboratoire de Thermodynamique et Energetique des Fluides Complexes - UMR 5150, Universite de Pau et des Pays de l' Adour, BP 1155, 64013 Pau (France)

    2010-08-10

    Nowadays, the experimental thermodynamic characterization of solvents in an extended range of temperatures and pressures is essential for the development of a wide variety of industrial applications (refrigeration, reactors, pumping, etc.). Moreover, accurate experimental data are also the key for the successful development and subsequent benchmarking of thermodynamic theoretical models. In the particular case of isobaric heat capacities, there are quite a lot of reported experimental high temperature data but, on the other hand, low temperature data are practically inexistent for most compounds. Bearing this limitation in mind, the present work is focused on the development of a new calibration methodology for calorimetric determination of isobaric heat capacities in liquid state at low temperatures. For this purpose, a Calvet calorimeter, SETARAM BT 2.15 has been used. By means of the calibration procedure explained below, this calorimeter allows to determine phase transitions and thermodynamic properties in a wide range of temperature (233.15-473.15 K) and pressure (0.1-100 MPa).

  2. Responses to dry heat of men and women with similar aerobic capacities.

    Science.gov (United States)

    Frye, A J; Kamon, E

    1981-01-01

    Four men and four women with similar VO2max (56.33 +/- 4.05 and 54.08 +/- 4.27 ml.kg-1.min-1, respectively) exercised up to 3 h at 30% VO2max during heat stress tests (HST) before and after acclimation to dry heat [dry-bulb temperature (Tdb)/wet-bulb temperature (Twb) = 48/25 degrees C]. Rectal (Tre), tympanic sweat on the chest (msw), and total sweat rate (Msw) were recorded. There were no differences in the responses of the women between phases of the menstrual cycle. Tre, Tty, Tsk, and Tdb at the onset of sweating were similar in both sexes before and after acclimation. The nonacclimated men had significantly higher Msw and slower rise in Tre as compared to the nonacclimated women. Following acclimation these differences were no longer evident. Acclimation produced an increase in Msw in both sexes that was characterized by an increase in sweating sensitivity (delta msw/delta Tre). It was concluded that sex alone does not determine responses to heat stress. Consideration should also be given to the relative cardiovascular strain, state of acclimation, and the ambient conditions.

  3. Break in the Heat Capacity Change at 303 K for Complex Binding of Netropsin to AATT Containing Hairpin DNA Constructs

    Science.gov (United States)

    Freyer, Matthew W.; Buscaglia, Robert; Hollingsworth, Amy; Ramos, Joseph; Blynn, Meredith; Pratt, Rachael; Wilson, W. David; Lewis, Edwin A.

    2007-01-01

    Studies performed in our laboratory demonstrated the formation of two thermodynamically distinct complexes on binding of netropsin to a number of hairpin-forming DNA sequences containing AATT-binding regions. These two complexes were proposed to differ only by a bridging water molecule between the drug and the DNA in the lower affinity complex. A temperature-dependent isothermal titration calorimetry (ITC)-binding study was performed using one of these constructs (a 20-mer hairpin of sequence 5′-CGAATTCGTCTCCGAATTCG) and netropsin. This study demonstrated a break in the heat capacity change for the formation of the complex containing the bridging water molecule at ∼303 K. In the plot of the binding enthalpy change versus temperature, the slope (ΔCp) was −0.67 kcal mol−1 K−1 steeper after the break at 303 K. Because of the relatively low melting temperature of the 20-mer hairpin (341 K (68°C)), the enthalpy change for complex formation might have included some energy of refolding of the partially denatured hairpin, giving the suggestion of a larger ΔCp. Studies done on the binding of netropsin to similar constructs, a 24-mer and a 28-mer, with added GC basepairs in the hairpin stem to increase thermal stability, exhibit the same nonlinearity in ΔCp over the temperature range of from 275 to 333 K. The slopes (ΔCp) were −0.69 and −0.64 kcal mol−1 K−1 steeper after 303 K for the 24-mer and 28-mer, respectively. This observation strengthens the argument regarding the presence of a bridging water molecule in the lower affinity netropsin/DNA complex. The ΔCp data seem to infer that because the break in the heat capacity change function for the lower affinity binding occurs at the isoequilibrium temperature for water, water may be included or trapped in the complex. The fact that this break does not occur in the heat capacity change function for formation of the higher affinity complex can similarly be taken as evidence that water is not included in

  4. Heating capacity of rebound shortwave diathermy and moist hot packs at superficial depths.

    Science.gov (United States)

    Hawkes, Amanda R; Draper, David O; Johnson, A Wayne; Diede, Mike T; Rigby, Justin H

    2013-01-01

    The effectiveness of a new continuous diathermy unit, ReBound, as a heating modality is unknown. To compare the effects of ReBound diathermy with silicate-gel moist hot packs on tissue temperature in the human triceps surae muscle. Crossover study. University research laboratory. A total of 12 healthy, college-aged volunteers (4 men, 8 women; age = 22.2 ± 2.25 years, calf subcutaneous fat thickness = 7.2 ± 1.9 mm). On 2 different days, 1 of 2 modalities (ReBound diathermy, silicate-gel moist hot pack) was applied to the triceps surae muscle of each participant for 30 minutes. After 30 minutes, the modality was removed, and temperature decay was recorded for 20 minutes. Medial triceps surae intramuscular tissue temperature at a depth of 1 cm was measured using an implantable thermocouple inserted horizontally into the muscle. Measurements were taken every 5 minutes during the 30-minute treatment and every minute during the 20-minute temperature decay, for a total of 50 minutes. Treatment was analyzed through a 2 × 7 mixed-model analysis of variance with repeated measures. Temperature decay was analyzed through a 2 × 21 mixed-model analysis of variance with repeated measures. During the 30-minute application, tissue temperatures at a depth of 1 cm increased more with the ReBound diathermy than with the moist hot pack (F6,66 = 7.14, P diathermy and moist hot packs increased tissue temperatures 3.69°C ± 1.50°C and 2.82°C ± 0.90°C, respectively, from baseline. Throughout the temperature decay, ReBound diathermy produced a greater rate of heat dissipation than the moist hot pack (F20,222 = 4.42, P diathermy increased tissue temperature to moderate levels, which were greater than the levels reached with moist hot packs.

  5. Heat capacity jumps induced by magnetic field in the Er{sub 2}HoAl{sub 5}O{sub 12} garnet

    Energy Technology Data Exchange (ETDEWEB)

    Shevchenko, E.V. [Centre for Diagnostics of Functional Materials for Medicine, Pharmacology and Nanoelectronics, St. Petersburg State University, St. Petersburg, 198504 (Russian Federation); Charnaya, E.V., E-mail: charnaya@live.com [Physics Department, St. Petersburg State University, St. Petersburg, 198504 (Russian Federation); Lee, M.K. [Department of Physics, National Cheng Kung University, Tainan, 70101 Taiwan (China); NSC Instrument Center at NCKU, Tainan, 70101 Taiwan (China); Chang, L.J. [Department of Physics, National Cheng Kung University, Tainan, 70101 Taiwan (China); Khazanov, E.N.; Taranov, A.V. [Kotel' nikov Institute of Radio Engineering and Electronics RAS, 125009 (Russian Federation); Bugaev, A.S. [Moscow Institute of Physics and Technology, Moscow, 141700 (Russian Federation)

    2017-01-30

    Measurements of the heat capacity were carried out for the mixed Er{sub 2}HoAl{sub 5}O{sub 12} garnet at magnetic fields up to 15 T. The heat capacity variations at low temperatures were dominated by the Schottky anomalies. In addition, anomalous sharp steps in the heat capacity were observed in magnetic fields stronger than 8 T upon cooling as well as upon warming. The temperatures of the steps increased with increasing magnetic field. Jumps found upon cooling and warming were shifted relative to each other showing the thermal hysteresis. The sharp decrease in the heat capacity at low temperatures suggested the blocking of magnetic flips induced by strong enough magnetic fields. - Highlights: • Anomalous steps of the heat capacity were observed in the Er{sub 2}HoAl{sub 5}O{sub 12} garnet. • The steps are induced by magnetic field at low temperatures. • The temperatures of the steps increased with increasing magnetic field. • The steps show a pronounced thermal hysteresis. • The findings suggest the blocking of the magnetic moment flips at field.

  6. First principles based group additive values for the gas phase standard entropy and heat capacity of hydrocarbons and hydrocarbon radicals.

    Science.gov (United States)

    Sabbe, Maarten K; De Vleeschouwer, Freija; Reyniers, Marie-Françoise; Waroquier, Michel; Marin, Guy B

    2008-11-27

    In this work a complete and consistent set of 95 Benson group additive values (GAVs) for standard entropies S(o) and heat capacities C(p)(o) of hydrocarbons and hydrocarbon radicals is presented. These GAVs include 46 groups, among which 25 radical groups, which, to the best of our knowledge, have not been reported before. The GAVs have been determined from a set of B3LYP/6-311G(d,p) ideal gas statistical thermodynamics values for 265 species, consistently with previously reported GAVs for standard enthalpies of formation. One-dimensional hindered rotor corrections for all internal rotations are included. The computational methodology has been compared to experimental entropies (298 K) for 39 species, with a mean absolute deviation (MAD) between experiment and calculation of 1.2 J mol(-1) K(-1), and to 46 experimental heat capacities (298 K) with a resulting MAD = 1.8 J mol(-1) K(-1). The constructed database allowed evaluation of corrections on S(o) and C(p)(o) for non-nearest-neighbor effects, which have not been determined previously. The group additive model predicts the S(o) and C(p)(o) within approximately 5 J mol(-1) K(-1) of the ab initio values for 11 of the 14 molecules of the test set, corresponding to an acceptable maximal deviation of a factor of 1.6 on the equilibrium coefficient. The obtained GAVs can be applied for the prediction of S(o) and C(p)(o) for a wide range of hydrocarbons and hydrocarbon radicals. The constructed database also allowed determination of a large set of hydrogen bond increments, which can be useful for the prediction of radical thermochemistry.

  7. Zeolite Y adsorbents with high vapor uptake capacity and robust cycling stability for potential applications in advanced adsorption heat pumps

    Energy Technology Data Exchange (ETDEWEB)

    Li, XS; Narayanan, S; Michaelis, VK; Ong, TC; Keeler, EG; Kim, H; Mckay, IS; Griffin, RG; Wang, EN

    2015-01-01

    Modular and compact adsorption heat pumps (AHPs) promise an energy-efficient alternative to conventional vapor compression based heating, ventilation and air conditioning systems. A key element in the advancement of AHPs is the development of adsorbents with high uptake capacity, fast intracrystalline diffusivity and durable hydrothermal stability. Herein, the ion exchange of NaY zeolites with ingoing Mg2+ ions is systematically studied to maximize the ion exchange degree (IED) for improved sorption performance. It is found that beyond an ion exchange threshold of 64.1%, deeper ion exchange does not benefit water uptake capacity or characteristic adsorption energy, but does enhance the vapor diffusivity. In addition to using water as an adsorbate, the uptake properties of Mg, Na-Y zeolites were investigated using 20 wt.% MeOH aqueous solution as a novel anti-freeze adsorbate, revealing that the MeOH additive has an insignificant influence on the overall sorption performance. We also demonstrated that the lab-scale synthetic scalability is robust, and that the tailored zeolites scarcely suffer from hydrothermal stability even after successive 108-fold adsorption/desorption cycles. The samples were analyzed using N-2 sorption, Al-27/Si-29 MAS NMR spectroscopy, ICP-AES, dynamic vapor sorption, SEM, Fick's 2nd law and D-R equation regressions. Among these, close examination of sorption isotherms for H2O and N-2 adsorbates allows us to decouple and extract some insightful information underlying the complex water uptake phenomena. This work shows the promising performance of our modified zeolites that can be integrated into various AHP designs for buildings, electronics, and transportation applications. (C) 2014 Elsevier Inc. All rights reserved.

  8. Electronic miniband structure, heat capacity and magnetic susceptibility of monolayer and bilayer silicene in TI, VSPM and BI regimes

    Energy Technology Data Exchange (ETDEWEB)

    Yarmohammadi, Mohsen, E-mail: m.yarmohammadi69@gmail.com

    2017-04-11

    In the current work, we theoretically study the electronic band structure (EBS), electronic heat capacity (EHC) and magnetic susceptibility (MS) of three structures including monolayer, AA-stacked and AB-stacked bilayer silicene based on the Kane–Mele Hamiltonian model and Green's function method. The particular attention of this study is paid to the effect of external electric field on the aforementioned physical properties. By variation of the electric field, three phases are found: Topological insulator (TI), valley–spin polarized metal (VSPM) and band insulator (BI). Marvellously, its electronic minibands show that the spin-up contribution of charge carriers with lowest energy bands behaves like relativistic Dirac fermions with linear (parabolic) energy dispersions in monolayer (bilayer) case near the Dirac points. An insightful analysis shows that the maximum and minimum value of EHC peak appear for (AA) AB-stacked bilayer and monolayer silicene in TI (BI) regime while in MS curves appear for (AB) AA-stacked bilayer and monolayer lattices in TI (BI) regime, respectively. Moreover, we have observed a phase transition from antiferromagnetic to ferromagnetic and paramagnetic in the monolayer and bilayer structures in the VSPM regime based on the MS findings, respectively. - Highlights: • Comparison of electronic miniband structure of monolayer and bilayer silicene by using the Kane–Mele model and Green's function technique. • Investigation and comparison the electronic contribution of heat capacity for different configurations of silicene structures. • Observation of phase transition from antiferromagnetic to ferromagnetic and paramagnetic phase in the monolayer and bilayer cases, respectively.

  9. Measurement of the Electronic Thermal Conductance Channels and Heat Capacity of Graphene at Low Temperature

    Directory of Open Access Journals (Sweden)

    Kin Chung Fong

    2013-10-01

    Full Text Available The ability to transport energy is a fundamental property of the two-dimensional Dirac fermions in graphene. Electronic thermal transport in this system is relatively unexplored and is expected to show unique fundamental properties and to play an important role in future applications of graphene, including optoelectronics, plasmonics, and ultrasensitive bolometry. Here, we present measurements of bipolar thermal conductances due to electron diffusion and electron-phonon coupling and infer the electronic specific heat, with a minimum value of 10k_{B} (10^{-22}  J/K per square micron. We test the validity of the Wiedemann-Franz law and find that the Lorenz number equals 1.32×(π^{2}/3(k_{B}/e^{2}. The electron-phonon thermal conductance has a temperature power law T^{2} at high doping levels, and the coupling parameter is consistent with recent theory, indicating its enhancement by impurity scattering. We demonstrate control of the thermal conductance by electrical gating and by suppressing the diffusion channel using NbTiN superconducting electrodes, which sets the stage for future graphene-based single-microwave photon detection.

  10. Heat capacity studies of single-crystalline CePt{sub 4}In

    Energy Technology Data Exchange (ETDEWEB)

    Pikul, A.P. [Polish Academy of Sciences, Institute of Low Temperature and Structure Research, P Nr 1410, 50-950 Wroclaw 2 (Poland); Max Planck Institute for Chemical Physics of Solids, Noethnitzer Str. 40, 01187 Dresden (Germany)], E-mail: A.Pikul@int.pan.wroc.pl; Kaczorowski, D.; Bukowski, Z. [Polish Academy of Sciences, Institute of Low Temperature and Structure Research, P Nr 1410, 50-950 Wroclaw 2 (Poland); Steglich, F. [Max Planck Institute for Chemical Physics of Solids, Noethnitzer Str. 40, 01187 Dresden (Germany)

    2008-04-01

    Single crystals of CePt{sub 4}In have been studied by means of specific heat measurements performed at low temperatures (down to 60 mK) and in high magnetic fields (up to 9 T). In zero magnetic field the {delta}C/T ratio strongly increases with decreasing temperature down to about 250 mK, where a broad maximum ({approx}1.75Jmol{sup -1}K{sup -2}) occurs. At lower temperatures {delta}C/T slightly diminishes and finally saturates at a value of about 1.7Jmol{sup -1}K{sup -2}. Upon applying magnetic field the maximum in {delta}C/T(T) disappears (it is not visible already in 0.5 T) and the magnitude of {delta}C/T becomes significantly lower. We argue that the observed anomaly in {delta}C(T)/T is due to some magnetic ordering of the cerium magnetic moments, in line with our previous statement on the localized character of the 4f-electrons in this compound.

  11. Assessment of Potential Capacity Increases at Combined Heat and Power Facilities Based on Available Corn Stover and Forest Logging Residues

    Directory of Open Access Journals (Sweden)

    Donald L. Grebner

    2013-08-01

    Full Text Available Combined Heat and Power (CHP production using renewable energy sources is gaining importance because of its flexibility and high-energy efficiency. Biomass materials, such as corn stover and forestry residues, are potential sources for renewable energy for CHP production. In Mississippi, approximately 4.0 MT dry tons of woody biomass is available annually for energy production. In this study, we collected and analyzed 10 years of corn stover data (2001–2010 and three years of forest logging residue data (1995, 1999, and 2002 in each county in Mississippi to determine the potential of these feed stocks for sustainable CHP energy production. We identified six counties, namely Amite, Copiah, Clarke, Wayne, Wilkinson and Rankin, that have forest logging residue feedstocks to sustain a CHP facility with a range of capacity between 8.0 and 9.8 MW. Using corn stover alone, Yazoo and Washington counties can produce 13.4 MW and 13.5 MW of energy, respectively. Considering both feedstocks and based on a conservative amount of 30% available forest logging residue and 33% corn stover, we found that 20 counties have adequate supply for a CHP facility with a capacity of 8.3 MW to 19.6 MW.

  12. Heat capacities and volumetric changes in the glass transition range: a constitutive approach based on the standard linear solid

    Science.gov (United States)

    Lion, Alexander; Mittermeier, Christoph; Johlitz, Michael

    2017-09-01

    A novel approach to represent the glass transition is proposed. It is based on a physically motivated extension of the linear viscoelastic Poynting-Thomson model. In addition to a temperature-dependent damping element and two linear springs, two thermal strain elements are introduced. In order to take the process dependence of the specific heat into account and to model its characteristic behaviour below and above the glass transition, the Helmholtz free energy contains an additional contribution which depends on the temperature history and on the current temperature. The model describes the process-dependent volumetric and caloric behaviour of glass-forming materials, and defines a functional relationship between pressure, volumetric strain, and temperature. If a model for the isochoric part of the material behaviour is already available, for example a model of finite viscoelasticity, the caloric and volumetric behaviour can be represented with the current approach. The proposed model allows computing the isobaric and isochoric heat capacities in closed form. The difference c_p -c_v is process-dependent and tends towards the classical expression in the glassy and equilibrium ranges. Simulations and theoretical studies demonstrate the physical significance of the model.

  13. Environmentally friendly and highly productive bi-component melt spinning of thermoregulated smart polymer fibres with high latent heat capacity

    Directory of Open Access Journals (Sweden)

    Ch. Cherif

    2018-03-01

    Full Text Available A stable and reproducible bi-component melt spinning process on an industrial scale incorporating Phase Change Material (PCM into textile fibres has been successfully developed and carried out using a melt spinning machine. The key factor for a successful bi-component melt spinning process is that a deep insight into the thermal and rheological behaviour of PCM using Difference Scanning Calorimetry (DSC, Thermogravimetric Analysis (TGA, and an oscillatory rheological investigation. PCM is very sensitive to the temperature and residence time of the melt spinning process. It is found that the optimal process temperature of PCM is 210 °C. The textile-physical properties and the morphology of the melt spun and further drawn bi-component core and sheath fibres (bico fibres were investigated and interpreted. The heat capacities of PCM incorporated in bico fibres were also determined by means of DSC. The melt spun bico fibres integrating PCM provide a high latent heat of up to 22 J/g, which is three times higher than that of state-of-the-art fibres, which were also obtained using the melt spinning process. Therefore, they have the potential to be used as smart polymer fibres for textile and other technical applications.

  14. An adiabatic calorimeter for heat capacity measurements of polyurethane foam with blowing agent of HFC245fa in the temperature range 60-290K

    Energy Technology Data Exchange (ETDEWEB)

    Yang, C.G.; Xu, L.; Zhang, L.Q.; Chen, N. [Institute of Refrigeration and Cryogenics, Shanghai Jiao Tong University, Shanghai 200030 (China)

    2006-06-15

    In order to meet the urgent need of heat insulating materials used under low temperature in the area of aerospace, a new polyurethane (PU) foam with HFC245fa as blowing agent was developed. In this paper, the heat capacity in the temperature range of 60-290K of the new material was measured through an automated adiabatic calorimeter, which was composed of a heat insulation system, a power measuring system, a vacuum pumping system and a cooling system. The sample cell of the calorimeter was equipped with a miniature platinum thermometer surrounded by two adiabatic shields and housed in a high vacuum can. The temperature differences among the sample cell and the inner and outer adiabatic shields could be adjusted automatically to less than 0.05K, all which ensure there was no heat exchange between the sample and surroundings. Under these conditions, the mathematical formulation of the sample with the physical model was given. Through measuring the heat capacity of {alpha}-Al{sub 2}O{sub 3}, which is a standard reference material, a relatively high reliability with a deviation of +/-2.5% of this adiabatic calorimeter was shown compared with the standard data. The results indicate that the newly developed PU foam has a higher heat capacity compared with other heat insulating materials, and there is no obvious sign of any phase transition or thermal anomaly in the entire temperature range. That is to say, the material is thermodynamically stable when used in the low temperature range. (author)

  15. An adiabatic calorimeter for heat capacity measurements of polyurethane foam with blowing agent of HFC245fa in the temperature range 60-290 K

    Energy Technology Data Exchange (ETDEWEB)

    Yang, C.G. [Institute of Refrigeration and Cryogenics, Shanghai Jiao Tong University, Shanghai 200030 (China)]. E-mail: chunguang_yang@sjtu.edu.cn; Xu, L. [Institute of Refrigeration and Cryogenics, Shanghai Jiao Tong University, Shanghai 200030 (China); Zhang, L.Q. [Institute of Refrigeration and Cryogenics, Shanghai Jiao Tong University, Shanghai 200030 (China); Chen, N. [Institute of Refrigeration and Cryogenics, Shanghai Jiao Tong University, Shanghai 200030 (China)

    2006-06-15

    In order to meet the urgent need of heat insulating materials used under low temperature in the area of aerospace, a new PU foam with HFC245fa as blowing agent was developed. In this paper, the heat capacity in the temperature range of 60-290 K of the new material was measured through an automated adiabatic calorimeter, which was composed of a heat insulation system, a power measuring system, a vacuum pumping system and a cooling system. The sample cell of the calorimeter was equipped with a miniature platinum thermometer surrounded by two adiabatic shields and housed in a high vacuum can. The temperature differences among the sample cell and the inner and outer adiabatic shields could be adjusted automatically to less than 0.05 K, all which ensure there was no heat exchange between the sample and surroundings. Under these conditions, the mathematical formulation of the sample with the physical model was given. Through measuring the heat capacity of {alpha}-Al{sub 2}O{sub 3}, which is a standard reference material, a relatively high reliability with a deviation of {+-}2.5% of this adiabatic calorimeter was shown compared with the standard data. The results indicate that the newly developed PU foam has a higher heat capacity compared with other heat insulating materials, and there is no obvious sign of any phase transition or thermal anomaly in the entire temperature range. That is to say, the material is thermodynamically stable when used in the low temperature range.

  16. Heat capacity of quantum adsorbates: Hydrogen and helium on evaporated gold films

    Energy Technology Data Exchange (ETDEWEB)

    Birmingham, J.T. [Univ. of California, Berkeley, CA (United States). Dept. of Physics]|[Lawrence Berkeley National Lab., CA (United States). Materials Sciences Div.

    1996-06-01

    The author has constructed an apparatus to make specific heat measurements of quantum gases adsorbed on metallic films at temperatures between 0.3 and 4 K. He has used this apparatus to study quench-condensed hydrogen films between 4 and 923 layers thick with J = 1 concentrations between 0.28 and 0.75 deposited on an evaporated gold surface. He has observed that the orientational ordering of the J = 1 molecules depends on the substrate temperature during deposition of the hydrogen film. He has inferred that the density of the films condensed at the lowest temperatures is 25% higher than in bulk H{sub 2} crystals and have observed that the structure of those films is affected by annealing at 3.4 K. The author has measured the J = 1 to J = 0 conversion rate to be comparable to that of the bulk for thick films; however, he found evidence that the gold surface catalyzes conversion in the first two to four layers. He has also used this apparatus to study films of {sup 4}He less than one layer thick adsorbed on an evaporated gold surface. He shows that the phase diagram of the system is similar to that for {sup 4}He/graphite although not as rich in structure, and the phase boundaries occur at different coverages and temperatures. At coverages below about half a layer and at sufficiently high temperatures, the {sup 4}He behaves like a two-dimensional noninteracting Bose gas. At lower temperatures and higher coverages, liquidlike and solidlike behavior is observed. The Appendix shows measurements of the far-infrared absorptivity of the high-{Tc} superconductor La{sub 1.87}Sr{sub 0.13}CuO{sub 4}.

  17. Avian thermoregulation in the heat: evaporative cooling capacity in an archetypal desert specialist, Burchell's sandgrouse (Pterocles burchelli).

    Science.gov (United States)

    McKechnie, Andrew E; Smit, Ben; Whitfield, Maxine C; Noakes, Matthew J; Talbot, William A; Garcia, Mateo; Gerson, Alexander R; Wolf, Blair O

    2016-07-15

    Sandgrouse (Pterocliformes) are quintessential examples of avian adaptation to desert environments, but relatively little is known about the limits to their heat tolerance and evaporative cooling capacity. We predicted that evaporative cooling in Burchell's sandgrouse (Pterocles burchelli) is highly efficient and provides the basis for tolerance of very high air temperature (Ta). We measured body temperature (Tb), resting metabolic rate (RMR) and evaporative water loss (EWL) at Ta between 25°C and ∼58°C in birds exposed to successive increments in Ta Normothermic Tb averaged 39.0°C, lower than typical avian values. At Ta>34.5°C, Tb increased linearly to a maximum of 43.6°C at Ta=56°C. The upper critical limit of thermoneutrality (Tuc) was Ta=43.8°C, closely coinciding with the onset of panting and gular flutter. Above the Tuc, RMR increased 2.5-fold to 2.89 W at Ta=56°C, a fractional increase far exceeding that of many other species under comparable conditions. Rates of EWL increased rapidly at Ta>42.9°C to 7.84±0.90 g h(-1) at Ta=56°C, an 11-fold increase above minimal levels. Maximum evaporative cooling efficiency (ratio of evaporative heat loss to metabolic heat production) was 2.03, but could be as high as 2.70 if our assumption that the birds were metabolising lipids is incorrect. Thermoregulation at very high Ta in P. burchelli was characterised by large increases in RMR and EWL, and is much less efficient than in taxa such as columbids and caprimulgids. © 2016. Published by The Company of Biologists Ltd.

  18. The heat capacity and density of solutions of barium and tetrabutylammonium iodides in N-methylpyrrolidone at 298.15 K

    Science.gov (United States)

    Novikov, A. N.; Lenina, O. F.; Vasilev, V. A.

    2009-03-01

    The heat capacity and density of solutions of barium and tetrabutylammonium iodides in N-methylpyrrolidone (MP) were studied at 298.15 K by calorimetry and densimetry. The standard partial molar heat capacities and volumes ( overline {C_{p^2 }^ circ } and overline {V_2^ circ } ) of the electrolytes in MP were calculated. The standard heat capacities overline {C_{pi}^ circ } and volumes overline {V_i^ circ } of the Ba2+ and (C4H9)4N+ ions in solution in MP at 298.15 K were determined. With the tetrabutylammonium ion, these values were in agreement with those calculated on the basis of the tetraphenylarsonium-tetraphenyl borate and tetraphenylphosphonium-tetraphenyl borate assumptions. The results are discussed in relation to the special features of solvation in solutions of the salts studied.

  19. Thermodynamic properties in the normal and superconducting states of Na(x)CoO(2)*yH(2)O powder measured by heat capacity experiments

    OpenAIRE

    Lorenz, B.; Cmaidalka, J.; Meng, R. L.; Chu, C. W.

    2003-01-01

    The heat capacity of superconducting Na(x)CoO(2)*yH(2)O was measured and the data are discussed based on three different models: The thermodynamic Ginzburg-Landau model, the BCS theory, and a model including the effects of line nodes in the superconducting gap function. The electronic heat capacity is separated from the lattice contribution in a thermodynamically consistent way maintaining the entropy balance of superconducting and normal states at the critical temperature. It is shown that f...

  20. Molar Heat Capacity (Cv) for Saturated and Compressed Liquid and Vapor Nitrogen from 65 to 300 K at Pressures to 35 MPa.

    Science.gov (United States)

    Magee, J W

    1991-01-01

    Molar heat capacities at constant volume (Cv ,) for nitrogen have been measured with an automated adiabatic calorimeter. The temperatures ranged from 65 to 300 K, while pressures were as high as 35 MPa. Calorimetric data were obtained for a total of 276 state conditions on 14 isochores. Extensive results which were obtained in the saturated liquid region (Cv((2)) and Cσ ) demonstrate the internal consistency of the Cv (ρ,T) data and also show satisfactory agreement with published heat capacity data. The overall uncertainty of the Cv values ranges from 2% in the vapor to 0.5% in the liquid.

  1. Numerical Investigation on the Heat Extraction Capacity of Dual Horizontal Wells in Enhanced Geothermal Systems Based on the 3-D THM Model

    Directory of Open Access Journals (Sweden)

    Zhixue Sun

    2018-01-01

    Full Text Available The Enhanced Geothermal System (EGS constructs an artificial thermal reservoir by hydraulic fracturing to extract heat economically from hot dry rock. As the core element of the EGS heat recovery process, mass and heat transfer of working fluid mainly occurs in fractures. Since the direction of the natural and induced fractures are generally perpendicular to the minimum principal stress in the formation, as an effective stimulation approach, horizontal well production could increase the contact area with the thermal reservoir significantly. In this paper, the thermal reservoir is developed by a dual horizontal well system and treated as a fractured porous medium composed of matrix rock and discrete fracture network. Using the local thermal non-equilibrium theory, a coupled THM mathematical model and an ideal 3D numerical model are established for the EGS heat extraction process. EGS heat extraction capacity is evaluated in the light of thermal recovery lifespan, average outlet temperature, heat production, electricity generation, energy efficiency and thermal recovery rate. The results show that with certain reservoir and production parameters, the heat production, electricity generation and thermal recovery lifespan can achieve the commercial goal of the dual horizontal well system, but the energy efficiency and overall thermal recovery rate are still at low levels. At last, this paper puts forward a series of optimizations to improve the heat extraction capacity, including production conditions and thermal reservoir construction design.

  2. Effect of Al₂O₃ nanoparticle dispersion on the specific heat capacity of a eutectic binary nitrate salt for solar power applications

    OpenAIRE

    Hu, Y.; Y. He; Z.; Zhang; Wen, D

    2017-01-01

    Molten salts can be used as heat transfer fluids or thermal storage materials in a concentrated solar power plant. Improving the thermal properties can influence the utilization efficiency of solar energy. In this study, the effect of doping eutectic binary salt solvent with Al₂O₃ nanoparticles on its specific heat capacity (cp) was investigated. The effects of the mass fraction of nanoparticles on the cp of the composite nanofluid were analyzed, using both differential scanning calorimetry m...

  3. Introduction of Differential Scanning Calorimetry in a General Chemistry Laboratory Course: Determination of Heat Capacity of Metals and Demonstration of Law of Dulong and Petit

    Science.gov (United States)

    D'Amelia, Ronald P.; Stracuzzi, Vincent; Nirode, William F.

    2008-01-01

    Today's general chemistry students are introduced to many of the principles and concepts of thermodynamics. In first-year general chemistry undergraduate courses, thermodynamic properties such as heat capacity are frequently discussed. Classical calorimetric methods of analysis and thermal equilibrium experiments are used to determine heat…

  4. Effect of crystallinity and irradiation on thermal properties and specific heat capacity of LDPE and LDPE/EVA

    Energy Technology Data Exchange (ETDEWEB)

    Borhani zarandi, Mahmoud, E-mail: mborhani@yazduni.ac.ir [Physics Department, Yazd University, Yazd (Iran, Islamic Republic of); Amrollahi Bioki, Hojjat; Mirbagheri, Zahra-alsadat [Physics Department, Yazd University, Yazd (Iran, Islamic Republic of); Tabbakh, Farshid [Institute of Nuclear Science and Technology, Tehran (Iran, Islamic Republic of); Mirjalili, Ghazanfar [Physics Department, Yazd University, Yazd (Iran, Islamic Republic of)

    2012-01-15

    In this paper a series of low-density polyethylene (LDPE) blends with different percentages (10%, 20%, and 30%) of EVA and sets of low-density polyethylene sheets were prepared. This set consists of four subsets, which were made under different cooling methods: fast cooling in liquid nitrogen, cooling with cassette, exposing in open air, and cooling in oven, to investigate the crystallinity effects. All of the samples were irradiated with 10 MeV electron-beam in the dose range of 0-250 kGy using a Rhodotron accelerator system. The variation of thermal conductivity (k) and specific heat capacity (C{sub p}) of all of the samples were measured. We found that, for the absorption dose less than 150 kGy, k of the LDPE samples at a prescribed temperature range decreased by increasing the amount of dose, but then the change is insignificant. With increasing the crystallinity, k of the LDPE samples increased, whereas C{sub p} of this material is decreased. In the case of LDPE/EVA blends, for the dose less than 150 kGy, C{sub p} (at 40 Degree-Sign C) and k (in average) decreased, but then the change is insignificant. With increasing the amount of additive (EVA), C{sub p} and k increased.

  5. Temperature dependence of the heat capacities in the solid state of 18 mono-, di-, and poly-saccharides

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez-Segura, Gerardo O. [Laboratorio de Biofisicoquimica, Departamento de Fisicoquimica, Facultad de Quimica, Universidad Nacional Autonoma de Mexico, Mexico D.F. 04510 (Mexico); Campos, Myriam [Departamento de Quimica, Centro de Investigacion y Estudios Avanzados del I.P.N., Apdo. Postal 14-740, Mexico D.F. 07000 (Mexico); Costas, Miguel [Laboratorio de Biofisicoquimica, Departamento de Fisicoquimica, Facultad de Quimica, Universidad Nacional Autonoma de Mexico, Mexico D.F. 04510 (Mexico)], E-mail: costasmi@servidor.unam.mx; Torres, Luis A. [Departamento de Quimica, Centro de Investigacion y Estudios Avanzados del I.P.N., Apdo. Postal 14-740, Mexico D.F. 07000 (Mexico)], E-mail: ltorres@cinvestav.mx

    2009-01-15

    The temperature dependence of the heat capacities in solid state C{sub p}(T) of 18 mono-, di-, and poly-saccharides has been determined using a power-compensation differential scanning calorimeter. The saccharides were {alpha}-D-xylose, D-ribose, 2-deoxy-D-ribose, methyl-{beta}-D-ribose, {alpha}-D-glucose, 2-deoxy-D-glucose, {alpha}-D-mannose, {beta}-D-fructose, {alpha}-D-galactose, methyl-{alpha}-D-glucose, sucrose, maltose monohydrate, {alpha}-lactose monohydrate, cellobiose, maltotriose, N-acetyl-D-glucosamine, {alpha}-cyclodextrin, and {beta}-cyclodextrin. The measurements were carried out at atmospheric pressure and from T = (288.15 to 358.15) K for 15 saccharides and from T = (288.15 to 328.15) K for D-ribose, 2-deoxy-D-ribose, and methyl-{beta}-D-ribose. The present results are compared against literature values both at single temperatures, where most of the data are available, and throughout a range of temperatures, i.e., for C{sub p}(T). The predictions of a recently published correlation for organic solids are briefly discussed. By grouping saccharides in subsets, our present results can be used to compare amongst saccharide isomers and to assess the effect of different chemical groups and molecular size.

  6. Preliminary phase relations involving glaucophane and applications to high pressure petrology: new heat capacity and thermodynamic data

    Science.gov (United States)

    Holland, Timothy J. B.

    1988-05-01

    New heat capacity measurements and cell volume data are presented for a very magnesian glaucophane from a Tauern Window eclogite. These data are combined with estimated entropy, thermal expansion, and compressibility data to generate an enthalpy of formation for glaucophane from experimentally determined phase equilibria. The data are supported by preliminary experiments of the author and provide consistent calculations on the pressure of formation of the Tauern eclogites and on the position of the blueschist-greenschist transformation reaction as studied experimentally by Maruyama et al. (1986). The resulting thermodynamic data for glaucophane may be combined with the dataset of Holland and Powell (1985) to calculate phase relations for blueschists and eclogites. The stability of magnesian glaucophane lies in the pressure range between 8 and 32 kbars at 400° C and between 13 and 33 kbars at 600° C, and the unusual eclogite assemblage of glaucophane+kyanite from the Tauern Window is restricted to pressures above 20 kbars at high water activity.

  7. The Effect of Moisture Content and Temperature on the Specific Heat Capacity of Nut and Kernel of Two Iranian Pistachio Varieties

    Directory of Open Access Journals (Sweden)

    A.R Salari Kia

    2014-04-01

    Full Text Available Pistachio has a special ranking among Iranian agricultural products. Iran is known as the largest producer and exporter of pistachio in the world. Agricultural products are imposed under different thermal treatments during storage and processing. Designing all these processes requires thermal parameters of the products such as specific heat capacity. Regarding the importance of pistachio processing as an exportable product, in this study the specific heat capacity of nut and kernel of two varieties of Iranian pistachio (Kalle-Ghochi and Badami were investigated at four levels of moisture content (initial moisture content (5%, 15%, 25% and 40% w.b. and three levels of temperature (40, 50 and 60°C. In both varieties, the differences between the data were significant at the 1% of probability; however, the effect of moisture content was greater than that of temperature. The results indicated that the specific heat capacity of both nuts and kernels increase logarithmically with increase of moisture content and also increase linearly with increase of temperature. This parameter has altered for nut and kernel of Kalle-Ghochi and Badami varieties within the range of 1.039-2.936 kJ kg-1 K-1, 1.236-3.320 kJ kg-1 K-1, 0.887-2.773 kJ kg-1 K-1 and 0.811-2.914 kJ kg-1 K-1, respectively. Moreover, for any given level of temperature, the specific heat capacity of kernels was higher than that of nuts. Finally, regression models with high R2 values were developed to predict the specific heat capacity of pistachio varieties as a function of moisture content and temperature

  8. A reduced core to skin temperature gradient, not a critical core temperature, affects aerobic capacity in the heat.

    Science.gov (United States)

    Cuddy, John S; Hailes, Walter S; Ruby, Brent C

    2014-07-01

    The purpose of this study was to determine the impact of the core to skin temperature gradient during incremental running to volitional fatigue across varying environmental conditions. A secondary aim was to determine if a "critical" core temperature would dictate volitional fatigue during running in the heat. 60 participants (n=49 male, n=11 female; 24±5 yrs, 177±11 cm, 75±13 kg) completed the study. Participants were uniformly stratified into a specific exercise temperature group (18 °C, 26 °C, 34 °C, or 42 °C) based on a 3-mile run performance. Participants were equipped with core and chest skin temperature sensors and a heart rate monitor, entered an environmental chamber (18 °C, 26 °C, 34 °C, or 42 °C), and rested in the seated position for 10 min before performing a walk/run to volitional exhaustion. Initial treadmill speed was 3.2 km h(-1) with a 0% grade. Every 3 min, starting with speed, speed and grade increased in an alternating pattern (speed increased by 0.805 km h(-1), grade increased by 0.5%). Time to volitional fatigue was longer for the 18 °C and 26 °C group compared to the 42 °C group, (58.1±9.3 and 62.6±6.5 min vs. 51.3±8.3 min, respectively, pskin gradient for the 18 °C and 26 °C groups was larger compared to 42 °C group (halfway: 2.6±0.7 and 2.0±0.6 vs. 1.3±0.5 for the 18 °C, 26 °C and 42 °C groups, respectively; finish: 3.3±0.7 and 3.5±1.1 vs. 2.1±0.9 for the 26 °C, 34 °C, and 42 °C groups, respectively, ptemperature and heart rate response during the exercise trials. The current data demonstrate a 13% and 22% longer run time to exhaustion for the 18 °C and 26 °C group, respectively, compared to the 42 °C group despite no differences in beginning and ending core temperatures or baseline 3-mile run time. This capacity difference appears to result from a magnified core to skin gradient via an environmental temperature advantageous to convective heat loss, and in part from an increased sweat rate. Copyright

  9. Effect of pH Changes on Antioxidant Capacity and the Content of Betalain Pigments During the Heating of a Solution of Red Beet Betalains

    Directory of Open Access Journals (Sweden)

    Mikołajczyk-Bator Katarzyna

    2017-06-01

    Full Text Available Red beets and their products are mainly consumed after processing. In this study, the effect of pH on changes in antioxidant capacity (AC and the content of betalain pigments were analysed during the heating of a betalain preparation solution. With pH ranging from 4 to 9 during the heat-treatment, the content of red pigments decreased depending on the pH level of the sample. The losses of red pigments in the investigated betalain preparation solution increased along with rising pH levels of the heated solution. The greatest losses were recorded at pH of 9.0. An opposite correlation was observed for yellow pigments. The content of yellow pigments in the heated betalain preparation solution was increasing along with increasing pH. The most pronounced increase in the content of yellow pigments was found at pH of 6.5 and 7.0. At the same time, the heated betalain preparation solution was shown to exhibit a higher antioxidant capacity at pH of 6.0 (14.9 μmol Trolox/mL than at pH of 4.0 (12.6 μmol Trolox/mL. It was observed that the increase in the antioxidant capacity in heated betalain preparation solutions with pH in the 6.0–6.5 range occurred as a result of increased concentrations of neobetanin, assessed by HPLC, within the pH range from 5.0 to 6.5.

  10. Comprehensive assessment of geographic variation in heat tolerance and hardening capacity in populations of Drosophila melanogaster from eastern Australia

    DEFF Research Database (Denmark)

    Sgro, Carla M.; Overgaard, Johannes; Kristensen, Torsten Nygård

    2010-01-01

    We examined latitudinal variation in adult and larval heat tolerance in Drosophila melanogaster from eastern Australia. Adults were assessed using static and ramping assays. Basal and hardened static heat knockdown time showed significant linear clines; heat tolerance increased towards the tropics......, particularly for hardened flies, suggesting that tropical populations have a greater hardening response. A similar pattern was evident for ramping heat knockdown time at 0.06 degrees C min-1 increase. There was no cline for ramping heat knockdown temperature (CTmax) at 0.1 degrees C min-1 increase. Acute...

  11. Determining the Optimal Capacities of Renewable-Energy-Based Energy Conversion Systems for Meeting the Demands of Low-Energy District Heating, Electricity, and District Cooling

    DEFF Research Database (Denmark)

    Tol, Hakan; Svendsen, Svend; Dincer, Ibrahim

    2015-01-01

    This chapter presents a method for determining the optimal capacity of a renewable-energy-based energy conversion system for meeting the energy requirements of a given district as considered on a monthly basis, with use of a low-energy district heating system operating at a low temperature, as low......, and the other for the Greater Toronto Area. Various climate conditions of the case areas in question caused different observations of nominal capacities for the energy conversion systems considered with single-production and multi-production based on different renewable energy sources....

  12. Effect of variable thermal conductivity and specific heat capacity on the calculation of the critical metal hydride thickness for Ti1.1CrMn

    DEFF Research Database (Denmark)

    Mazzucco, Andrea; Rokni, Masoud

    2014-01-01

    model is applied to the metal hydride system, with Ti 1.1 CrMn as the absorbing alloy, to predict the weight fraction of absorbed hydrogen and solid bed temperat ure . Dependencies of thermal conductivity and specific heat capacity upon pressure and hydrogen content respectively , are accounted for...... with activated powder and embedded heat exchanger makes difficult to set up experimental facilities. Trustable simulation models that can address the system ́s performances to a particular design are then a funda mental step to be taken prior any experimental setup. This study considers a detailed 1D fueling...

  13. Evaluating Moisture Control of Variable-Capacity Heat Pumps in Mechanically Ventilated, Low-Load Homes in Climate Zone 2A

    Energy Technology Data Exchange (ETDEWEB)

    Martin, Eric [University of Central Florida, Florida Solar Energy Center; Withers, Chuck [University of Central Florida, Florida Solar Energy Center; McIlvaine, Janet [University of Central Florida, Florida Solar Energy Center; Chasar, Dave [University of Central Florida, Florida Solar Energy Center; Beal, David [University of Central Florida, Florida Solar Energy Center

    2018-02-07

    The well-sealed, highly insulated building enclosures constructed by today's home building industry coupled with efficient lighting and appliances are achieving significantly reduced heating and cooling loads. These low-load homes can present a challenge when selecting appropriate space-conditioning equipment. Conventional, fixed-capacity heating and cooling equipment is often oversized for small homes, causing increased first costs and operating costs. Even if fixed-capacity equipment can be properly specified for peak loads, it remains oversized for use during much of the year. During these part-load cooling hours, oversized equipment meets the target dry-bulb temperatures very quickly, often without sufficient opportunity for moisture control. The problem becomes more acute for high-performance houses in humid climates when meeting ASHRAE Standard 62.2 recommendations for wholehouse mechanical ventilation.

  14. Ion association in N-methylpyrrolidone and the N-methylpyrrolidone-water mixed solvent from data on heat capacity and density of solutions

    Science.gov (United States)

    Solov'ev, S. N.; Novikov, A. N.

    2012-06-01

    Association constants for solutions of electrolytes in N-methylpyrrolidone (MP) and the MP-water mixed solvent at 298.15 K are calculated. It is shown that, over a wide range of concentrations, concentration dependences of apparent molar heat capacities and apparent molar volumes of the electrolytes in MP and MP-water mixtures are described adequately in terms of equilibria between ions and ion pairs of a single type in the solution.

  15. Thermodynamics of aqueous uranyl ion: Apparent and partial molar heat capacities and volumes of aqueous uranyl perchlorate from 10 to 55°C

    Science.gov (United States)

    Hovey, Jamey K.; Nguyen-Trung, Chinh; Tremaine, Peter R.

    1989-07-01

    Apparent molar heat capacities and volumes of aqueous solutions containing UO2(ClO4)2 in dilute (≈0.06 molal) HClO4 have been determined from 10 to 55°C. These results have been analyzed using Young's rule to obtain apparent molar volumes and heat capacities for the solute UO2(ClO42). The temperature dependences of the conventional standard-state heat capacity and volume functions for UO22+ (aq) are well represented by the following equations: V¯°/cm(30 mo1P-1) -80.94 + 0.6091 T - 0.001063T2 andC¯/p0/(J K-1 mol-1) = 350.5 - 0.8722T - 5308/T -90) that are valid from 10 to 55°C. These results differ substantially from results of earlier measurements employing different uranyl salts. These differences are likely due to the presence of ion-paired or hydrolyzed U (VI) species in the earlier studies.

  16. Thermophysical Properties of Cold- and Vacuum Plasma-Sprayed Cu-Cr-X Alloys, NiAl and NiCrAlY Coatings II: Specific Heat Capacity

    Science.gov (United States)

    Raj, S. V.

    2017-10-01

    Part I of the paper discussed the temperature dependencies of the electrical resistivities, thermal conductivities, thermal diffusivities and total hemispherical emissivities of several vacuum plasma-sprayed (VPS) and cold-sprayed (CS) copper alloy monolithic coatings, VPS NiAl, VPS NiCrAlY, extruded GRCop-84 and as-cast Cu-17(wt.%)Cr-5%Al. Part II discusses the temperature dependencies of the constant-pressure specific heat capacities, C P, of these coatings. The data were empirically regression-fitted with the equation: \\varvec{C}_{P} = AT^{4} + BT^{3} + CT^{2} + DT + \\varvec{E} where T is the absolute temperature and A, B, C, D and E are regression constants. The temperature dependencies of the molar enthalpy, molar entropy and Gibbs molar free energy determined from experimental values of molar specific heat capacity are reported. Calculated values of C P using the Neumann-Kopp (NK) rule were in poor agreement with experimental data. Instead, a modification of the NK rule was found to predict values closer to the experimental data with an absolute deviation less than 6.5%. The specific molar heat capacities for all the alloys did not agree with the Dulong-Petit law, and C P > 3R, where R is the universal gas constant, were measured for all the alloys except NiAl for which C P < 3R at all temperatures.

  17. Thermophysical Properties of Cold and Vacuum Plasma Sprayed Cu-Cr-X Alloys, NiAl and NiCrAlY Coatings. Part 2; Specific Heat Capacity

    Science.gov (United States)

    Raj, S. V.

    2017-01-01

    Part I of the paper discussed the temperature dependencies of the electrical resistivities, thermal conductivities, thermal diffusivities and total hemispherical emissivities of several vacuum plasma sprayed (VPS) and cold sprayed copper alloy monolithic coatings, VPS NiAl, VPS NiCrAlY, extruded GRCop-84 and as-cast Cu-17(wt.%)Cr-5%Al. Part II discusses the temperature dependencies of the constant pressure specific heat capacities, CP, of these coatings. The data were empirically were regression-fitted with the equation: CP = AT4 + BT3 + CT2 + DT +E where T is the absolute temperature and A, B, C, D and E are regression constants. The temperature dependencies of the molar enthalpy, molar entropy and Gibbs molar free energy determined from experimental values of molar specific heat capacity are reported. Calculated values of CP using the Neumann-Kopp (NK) rule were in poor agreement with experimental data. Instead, a modification of the Neumann-Kopp rule was found to predict values closer to the experimental data with an absolute deviation less than 6.5%. The specific molar heat capacities for all the alloys did not agree with the Dulong-Petit law, and CP is greater than 3R, where R is the universal gas constant, were measured for all the alloys except NiAl for which CP is less than 3R at all temperatures.

  18. Low temperature heat capacities and standard molar enthalpy of formation of sodium benzoate C{sub 6}H{sub 5}COONa (s)

    Energy Technology Data Exchange (ETDEWEB)

    Kong, Yu-Xia [College of Chemistry and Chemical Engineering, Liaocheng University, Liaocheng 252059, Shandong Province (China); Di, You-Ying, E-mail: yydi@lcu.edu.cn [College of Chemistry and Chemical Engineering, Liaocheng University, Liaocheng 252059, Shandong Province (China); Qi, Yu-Dong; Yang, Wei-Wei [College of Chemistry and Chemical Engineering, Liaocheng University, Liaocheng 252059, Shandong Province (China); Tan, Zhi-Cheng [Thermochemistry Laboratory, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023 (China)

    2009-05-05

    Sodium benzoate was synthesized by the method of liquid phase synthesis, in which benzoic acid and anhydrous sodium carbonate were chosen as the reactants. The structure and composition of the compound were characterized by FTIR, chemical analysis, elemental analysis and X-ray powder diffraction techniques. Low temperature heat capacities of the compound were measured by a precision automated adiabatic calorimeter over the temperature range from 78 to 400 K. A polynomial equation of the heat capacities as a function of the temperature was fitted by least square method. The smoothed heat capacities and the thermodynamic functions of the compound relative to 298.15 K have been calculated based on the equation. In accordance with Hess law, the standard molar enthalpy of formation of the title compound C{sub 6}H{sub 5}COONa (s) was determined to be {Delta}{sub f}H{sup o}{sub m}[C{sub 6}H{sub 5}COONa,s]=-(642.56{+-}0.64)kJmol{sup -1} by using an isoperibol solution-reaction calorimeter.

  19. Thermophysical Properties of Cold- and Vacuum Plasma-Sprayed Cu-Cr-X Alloys, NiAl and NiCrAlY Coatings II: Specific Heat Capacity

    Science.gov (United States)

    Raj, S. V.

    2017-11-01

    Part I of the paper discussed the temperature dependencies of the electrical resistivities, thermal conductivities, thermal diffusivities and total hemispherical emissivities of several vacuum plasma-sprayed (VPS) and cold-sprayed (CS) copper alloy monolithic coatings, VPS NiAl, VPS NiCrAlY, extruded GRCop-84 and as-cast Cu-17(wt.%)Cr-5%Al. Part II discusses the temperature dependencies of the constant-pressure specific heat capacities, C P, of these coatings. The data were empirically regression-fitted with the equation: \\varvec{C}_{P} = {AT}^{4} + {BT}^{3} + {CT}^{2} + DT + \\varvec{E}where T is the absolute temperature and A, B, C, D and E are regression constants. The temperature dependencies of the molar enthalpy, molar entropy and Gibbs molar free energy determined from experimental values of molar specific heat capacity are reported. Calculated values of C P using the Neumann-Kopp (NK) rule were in poor agreement with experimental data. Instead, a modification of the NK rule was found to predict values closer to the experimental data with an absolute deviation less than 6.5%. The specific molar heat capacities for all the alloys did not agree with the Dulong-Petit law, and C P > 3 R, where R is the universal gas constant, were measured for all the alloys except NiAl for which C P < 3 R at all temperatures.

  20. Heat

    CERN Document Server

    Lawrence, Ellen

    2016-01-01

    Is it possible to make heat by rubbing your hands together? Why does an ice cube melt when you hold it? In this title, students will conduct experiments to help them understand what heat is. Kids will also investigate concepts such as which materials are good at conducting heat and which are the best insulators. Using everyday items that can easily be found around the house, students will transform into scientists as they carry out step-by-step experiments to answer interesting questions. Along the way, children will pick up important scientific skills. Heat includes seven experiments with detailed, age-appropriate instructions, surprising facts and background information, a "conclusions" section to pull all the concepts in the book together, and a glossary of science words. Colorful, dynamic designs and images truly put the FUN into FUN-damental Experiments.

  1. An automated flow calorimeter for the determination of liquid and vapor isobaric heat capacities: Test results for water and n -pentane

    Energy Technology Data Exchange (ETDEWEB)

    Sandarusi, J.A. (National Institute of Science and Technology, Thermophysics Division, Boulder, Colorado 80303 (United States)); Mulia, K.; Yesavage, V.F. (Colorado School of Mines, Chemical Engineering Department, Golden, Colorado 80401 (United States))

    1992-02-01

    An automated flow calorimeter has been developed for the measurement of highly accurate isobaric heat capacities and enthalpies of fluids at elevated temperatures and pressures. The instrument was successfully tested over the range 300--600 K and 0--12 MPa and is readily extensible to 700 K and 30 MPa. The flow calorimeter relied on an adiabatic design with a two-chambered cell design incorporating several concentric shells of active and passive shields designed to minimize heat losses, facilitate easy component replacement, and eliminate any external temperature regulation baths. A pair of miniature standard platinum resistance thermometers were built to determine the differential calorimeter temperatures. A precision metering pump eliminated the need for direct mass flow-rate determinations while a complete automation system supplied all of the required data acquisition, monitoring, and control (except for pressure) resources necessary to operate the calorimeter and make measurements from a single personal computer. Measurements of isobaric heat capacities were performed on water (liq.) and {ital n}-pentane (liq. and vap.) to test the new calorimeter. These experiments compared well with the published values, indicating an overall measurement precision of 0.1% and uncertainty in the range of 0.2%--0.3%. The total calorimeter heat leak was small affecting the experimental uncertainty as much as the combined mass flow-rate and calorimeter temperature difference errors.

  2. Evaluation of an Absorption Heat Pump to Mitigate Plant Capacity Reduction Due to Ambient Temperature Rise for an Air-Cooled Ammonia and Water Cycle: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Bharathan, D.; Nix, G.

    2001-08-06

    Air-cooled geothermal plants suffer substantial decreases in generating capacity at increased ambient temperatures. As the ambient temperature rises by 50 F above a design value of 50 F, at low brine-resource temperatures, the decrease in generating capacity can be more than 50%. This decrease is caused primarily by increased condenser pressure. Using mixed-working fluids has recently drawn considerable attention for use in power cycles. Such cycles are more readily amenable to use of absorption ''heat pumps.'' For a system that uses ammonia and water as the mixed-working fluid, this paper evaluates using an absorption heat pump to reduce condenser backpressure. At high ambient temperatures, part of the turbine exhaust vapor is absorbed into a circulating mixed stream in an absorber in series with the main condenser. This steam is pumped up to a higher pressure and heated to strip the excess vapor, which is recondensed using an additional air-cooled condenser. The operating conditions are chosen to reconstitute this condensate back to the same concentration as drawn from the original system. We analyzed two power plants of nominal 1-megawatt capacity. The design resource temperatures were 250 F and 300 F. Ambient temperature was allowed to rise from a design value of 50 F to 100 F. The analyses indicate that using an absorption heat pump is feasible. For the 300 F resource, an increased brine flow of 30% resulted in a net power increase of 21%. For the 250 F resource, the increase was smaller. However, these results are highly plant- and equipment-specific because evaluations must be carried out at off-design conditions for the condenser. Such studies should be carried out for specific power plants that suffer most from increased ambient temperatures.

  3. An automated flow calorimeter for heat capacity and enthalpy measurements at elevated temperatures and pressures: Progress report for period March 1, 1988--February 29, 1989

    Energy Technology Data Exchange (ETDEWEB)

    Yesavage, V.F.

    1988-10-30

    The need for thermal property data at process conditions has been well documented in applications such as development of atmospherically inert refrigerants and design of petrochemical and synfuel plants. As such, the primary objective of this work is to construct an automated flow calorimeter to measure isobaric heat capacities and enthalpies of vaporization over the range 0--30MPa and 300--700K with an anticipated accuracy of 0.1%. The method of measurement is an adiabatic electrical power input technique with a unique calorimeter design utilizing a concentric coil/radiation shield structure which minimizes heat loss errors and simplifies the replacement of plugged components. Flow generation is accomplished with a precision Ruska pump eliminating the need for on-line flow rate measurement. In addition, the proposed instrument will be fully automated minimizing the need for highly skilled operators which had previously been a severe limitation with this type of instrument. Assembly of all hardware and implementation of the necessary software was completed within the past year. In addition, water was used as a heat capacity standard to evaluate overall system performance. Preliminary indications are that the apparatus is operating near expectations (+//minus/0.2%) although some additional hardware refinements may be necessary achieve the design goals of +//minus/0.1%. 15 refs., 4 figs., 1 tab.

  4. Change in heat capacity upon the solvation of alkali metal ions in N-methylpyrrolidone and mixed N-methylpyrrolidone-water solvent

    Science.gov (United States)

    Novikov, A. N.; Solov'ev, S. N.

    2012-09-01

    The change in heat capacity upon ion solvation Δsolv C {/p,i o} in N-methylpyrrolidone (MP) and in mixed MP-water solvent is presented as the sum of three contributions: electrostatic, cavity formation, and changes in the structure of the solvent. The values for the electrostatic and cavity formation contributions are calculated using model concepts. The values of the structural contribution are determined. The obtained data was analyzed in dependence on the solvent's composition and the electrostatic ion parameters.

  5. ESTIMATIONS OF HEAT CAPACITIES FOR ACTINIDE DIOXIDE: UO2, NpO2, ThO2, AND PuO2

    Directory of Open Access Journals (Sweden)

    E. ESER

    2014-12-01

    Full Text Available The evaluation of thermal properties of actinide oxide fuels is a problem of high importance for the development of new generation reactors. In the present study, an expression obtained for n-dimensional Debye functions is used to derive a simple analytical expression for the specific heat capacity of nuclear fuels. To test the validity and reliability of this expression, the analytical expression is applied to UO2, NpO2, ThO2, and PuO2. It is seen that the formula was in agreement with the experimental and theoretical results reported in the literature.

  6. Direct experimental evidence for a negative heat capacity in the liquid-to-gas like phase transition in hydrogen cluster ions backbending of the caloric curve

    CERN Document Server

    Gobet, F; Carré, M; Farizon, B; Farizon, M; Gaillard, M J; Maerk, T D; Scheier, P

    2002-01-01

    By (i) selecting specific decay reactions in high energy collisions (60 keV/amu) of hydrogen cluster ions with a helium target (utilizing event-by-event data of a recently developed multi-coincidence experiment) and by (ii) deriving corresponding temperatures for these microcanonical cluster ensembles (analyzing the respective fragment distributions) we are able to construct caloric curves for ii sub 3 sup + (ii sub 2) sub m cluster ions (6 <= m <= 14). All individual curves and the mean of these curves show a backbending in the plateau region thus constituting direct evidence for a negative microcanonical heat capacity in the liquid-to-gas like transition of these finite systems.

  7. Heat capacity and sticking probability measurements of sup 4 He submonolayers adsorbed on evaporated Ag films: Bose statistics in two dimensions

    Energy Technology Data Exchange (ETDEWEB)

    Kenny, T.W.; Richards, P.L. (Department of Physics, University of California, Berkeley, Berkeley, CA (USA) Materials and Chemical Sciences Division, Lawrence Berkeley Laboratories, Berkeley, CA (USA))

    1990-05-14

    We have measured the heat capacity of submonolayers of {sup 4}He adsorbed on Ag films between 1.7 and 3.3 K. Good fits to the results are obtained with a model of a noninteracting two-dimensional Bose gas. The sticking probability for room-temperature {sup 4}He atoms on cold Ag has been measured as a function of substrate temperature and {sup 4}He coverage. The sticking probability is 4% at low coverage, and abruptly drops to 1% for coverages above 0.5 monolayer.

  8. Dynamic Heat Storage and Cooling Capacity of a Concrete Deck with PCM and Thermally Activated Building System

    DEFF Research Database (Denmark)

    Pomianowski, Michal Zbigniew; Heiselberg, Per; Jensen, Rasmus Lund

    2012-01-01

    with and without microencapsulated PCM are presented. The new concrete deck with microencapsulated PCM is the standard deck on which an additional layer of the PCM concrete was added and, at the same time, the latent heat storage was introduced to the construction. The challenge of numerically simulating...

  9. Effects of Chlorination and Heat Treatment on Flour and Gluten Functionality Explored by Solvent Retention Capacity (SRC) and Mixograph

    Science.gov (United States)

    The effects of chlorination and heat treatment on flour and gluten functionality were explored by SRC and mixograph for the soft wheat cultivar, Croplan 594W. Regardless of milling yield, SRC results for chlorinated flour samples showed a decrease in lactic acid SRC values with increasing extent of...

  10. Thermolysis, nonisothermal decomposition kinetics, specific heat capacity and adiabatic time-to-explosion of [Cu(NH3)4](DNANT)2 (DNANT= dinitroacetonitrile).

    Science.gov (United States)

    Zhang, Yu; Wu, Hao; Xu, Kangzhen; Zhang, Wantao; Ren, Zhaoyu; Song, Jirong; Zhao, Fengqi

    2014-02-20

    A new energetic copper complex of dinitroacetonitrile (DNANT), [Cu(NH3)4](DNANT)2, was first synthesized through an unexpected reaction. The thermal decomposition of [Cu(NH3)4](DNANT)2 was studied with DSC and TG/DTG methods. The gas products were analyzed through a TG-FTIR-MS method. The nonisothermal kinetic equation of the exothermic process is dα/dT = 10(10.92)/β4(1 - α)[-ln(1 - α)](3/4) exp(-1.298 × 10(5)/RT). The self-accelerating decomposition temperature and critical temperature of thermal explosion are 217.9 and 221.0 °C. The specific heat capacity of [Cu(NH3)4](DNANT)2 was determined with a micro-DSC method, and the molar heat capacity is 512.6 J mol(-1) K(-1) at 25 °C. Adiabatic time-to-explosion of Cu(NH3)4(DNANT)2 was also calculated to be about 137 s.

  11. Comparison of Conventional and Microwave Assisted Heating on Carbohydrate Content, Antioxidant Capacity and Postprandial Glycemic Response in Oat Meals

    Directory of Open Access Journals (Sweden)

    Joanna Harasym

    2018-02-01

    Full Text Available Minimally processed cereal breakfast products from whole grain entered the market due to consumer demand of more nutritional food with more controlled sugar release. However, the subsequent processing of such products with different cooking methods in the consumer’s kitchen may lead to significant differentiation of their nutritional value. Therefore, the evaluation of the impact of frequently used cooking methods on a final quality of breakfast cereals meal is needed. The present study investigates how the two different methods of heating, conventional and microwave (MW assisted, affect the carbohydrate content, profile and resulting glycemic index of so prepared food as well as the antioxidant activity of meals. Two products available on the market—oat bran and flakes—were used. The highest starch content in fluid phase of oatmeal was detected in samples heated for 3 min with microwaves, regardless the type. The lowest starch content was obtained for 5 min MW heated flakes sample. The total content of glucose was about 1.5 times lower in bran vs. flakes oatmeal. The highest β-glucan content in fluid fraction was also observed for bran meal but its release was independent of applied conditions.

  12. The ingestion of combined carbohydrates does not alter metabolic responses or performance capacity during soccer-specific exercise in the heat compared to ingestion of a single carbohydrate.

    Science.gov (United States)

    Clarke, N D; Campbell, I T; Drust, B; Evans, L; Reilly, T; Maclaren, D P M

    2012-01-01

    This study was designed to investigate the effect of ingesting a glucose plus fructose solution on the metabolic responses to soccer-specific exercise in the heat and the impact on subsequent exercise capacity. Eleven male soccer players performed a 90 min soccer-specific protocol on three occasions. Either 3 ml · kg(-1) body mass of a solution containing glucose (1 g · min(-1) glucose) (GLU), or glucose (0.66 g · min(-1)) plus fructose (0.33 g · min(-1)) (MIX) or placebo (PLA) was consumed every 15 minutes. Respiratory measures were undertaken at 15-min intervals, blood samples were drawn at rest, half-time and on completion of the protocol, and muscle glycogen concentration was assessed pre- and post-exercise. Following the soccer-specific protocol the Cunningham and Faulkner test was performed. No significant differences in post-exercise muscle glycogen concentration (PLA, 62.99 ± 8.39 mmol · kg wet weight(-1); GLU 68.62 ± 2.70; mmol · kg wet weight(-1) and MIX 76.63 ± 6.92 mmol · kg wet weight(-1)) or exercise capacity (PLA, 73.62 ± 8.61 s; GLU, 77.11 ± 7.17 s; MIX, 83.04 ± 9.65 s) were observed between treatments (P > 0.05). However, total carbohydrate oxidation was significantly increased during MIX compared with PLA (P carbohydrate does not influence metabolism during soccer-specific intermittent exercise or affect performance capacity after exercise in the heat.

  13. Heat capacity measurement and EXAFS study of (U{sub 0.85}Mg{sub 0.15})O{sub 2{minus}x} for x = 0 and 0.1

    Energy Technology Data Exchange (ETDEWEB)

    Atita, Y; Matsui, T. [Nagoya Univ. (Japan); Ohno, H. [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Office of Synchrotron Radiation Facility Project; Kobayashi, K. [National Lab. for High Energy Physics, Tsukuba, Ibaraki (Japan). Photon Factory

    1997-03-01

    Heat capacities and electrical conductivities of (U{sub 0.85}Mg{sub 0.15})O{sub 2{minus}x} (x = 0 and 0.1) were measured simultaneously by means of a direct heating pulse calorimeter (DHPC) in the temperature range from 300 to 1500 K. Anomalous increases in the heat capacity curves of (U{sub 0.85}Mg{sub 0.15})O{sub 2{minus}x} (x = 0 and 0.1) were observed above about 800 and 1150 K, respectively. The values for the enthalpy of oxygen Frenkel defect formation were calculated from the excess heat capacity and were found to be similar to those for UO{sub 2} doped with rare earth elements. On the other hand, no anomaly was seen in the electrical conductivity curve around the onset temperature of the anomalous increase in the heat capacity. It was, therefore, concluded that the excess heat capacity originates from the predominant contribution of the formation of Frenkel pair-like defects of oxygen. An extended X-ray absorption fine structure (EXAFS) experiment shows a different environment of oxygen around uranium and magnesium, and this should be a cause of the onset temperature difference.

  14. Thermal management of instruments on space platforms using a high capacity two-phase heat transport system

    Science.gov (United States)

    Ollendorf, S.; Fowle, A.; Almgren, D.

    1981-01-01

    A system utilizing a pumped, two-phase single component working fluid for heat exchange and transport services necessary to meet the temperature control requirements of typical orbiting instrument payloads on space platforms is described. The design characteristics of the system is presented, together with a presentation of a laboratory apparatus for demonstration of proof of concept. Results indicate that the pumped two-phase design concept can meet a wide range of thermal performance requirements with the only penalty being the requirement for a small liquid pump.

  15. Determination of heat-set gelation capacity of a quinoa protein isolate (Chenopodium quinoa) by dynamic oscillatory rheological analysis.

    Science.gov (United States)

    Kaspchak, Elaine; Oliveira, Marco Aurelio Schüler de; Simas, Fernanda Fogagnoli; Franco, Célia Regina Cavicchiolo; Silveira, Joana Léa Meira; Mafra, Marcos Rogério; Igarashi-Mafra, Luciana

    2017-10-01

    This work aimed to study the influence of pH (3.5 and 7.0) and CaCl2 and MgCl2 addition on heat-set gelation of a quinoa protein isolate at 10% and 15% (w/w). The protein isolate obtained was composed mainly of 11S globulin as was observed by electrophoresis and mass spectrometry analysis. Heat-set gelation occurred at both pH values studied. Nevertheless, the gels formed at pH 3.5 were more viscoelastic and denser than those formed at pH 7.0, that was coarser and presented syneresis. The CaCl2 and MgCl2 addition increased the gel strength during rheological analysis at pH 3.5, possibly due to the formation of fiber-like connections in the gel network. At pH 7.0, the divalent salts resulted in weaker gels formed by agglomerates, suggesting a neutralization of the protein surface charges. The differences in quinoa protein gelation were attributed to solubility, and the flexibility of proteins secondary structure at the pH studied. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. The Expression of Carnosine and Its Effect on the Antioxidant Capacity of Muscle in Finishing Pigs Exposed to Constant Heat Stress

    Directory of Open Access Journals (Sweden)

    Peige Yang

    2014-12-01

    Full Text Available The objective of this study was to assess the effects of constant high ambient temperatures on meat quality, antioxidant capacity, and carnosine expression in longissimus dorsi muscle of finishing pigs. Castrated 24 male DLY (crossbreeds between Landrace×Yorkshire sows and Duroc boars pigs were allocated to one of three treatments: constant ambient temperature at 22°C and ad libitum feeding (CON, n = 8; constant high ambient temperature at 30°C and ad libitum feeding (H30, n = 8; and constant ambient temperature at 22°C and pair-fed with H30 (PF, n = 8. Meat quality, malondialdehyde (MDA content, antioxidant capacity, carnosine content, and carnosine synthetase (CARNS1 mRNA expression in longissimus dorsi muscle were measured after three weeks. The results revealed that H30 had lower pH24 h, redness at 45 min, and yellowness at 24 h post-mortem (p<0.05, and higher drip loss at 48 h and lightness at 24 h post-mortem (p<0.01. Constant heat stress disrupted the pro-oxidant/antioxidant balance in longissimus dorsi muscle with higher MDA content (p<0.01 and lower antioxidant capacity (p<0.01. Carnosine content and CARNS1 mRNA expression in longissimus dorsi muscle of H30 pigs were significantly decreased (p<0.01 after three weeks at 30°C. In conclusion, constant high ambient temperatures affect meat quality and antioxidant capacity negatively, and the reduction of muscle carnosine content is one of the probable reasons.

  17. Force Field Benchmark of Organic Liquids: Density, Enthalpy of Vaporization, Heat Capacities, Surface Tension, Isothermal Compressibility, Volumetric Expansion Coefficient, and Dielectric Constant

    Science.gov (United States)

    2011-01-01

    The chemical composition of small organic molecules is often very similar to amino acid side chains or the bases in nucleic acids, and hence there is no a priori reason why a molecular mechanics force field could not describe both organic liquids and biomolecules with a single parameter set. Here, we devise a benchmark for force fields in order to test the ability of existing force fields to reproduce some key properties of organic liquids, namely, the density, enthalpy of vaporization, the surface tension, the heat capacity at constant volume and pressure, the isothermal compressibility, the volumetric expansion coefficient, and the static dielectric constant. Well over 1200 experimental measurements were used for comparison to the simulations of 146 organic liquids. Novel polynomial interpolations of the dielectric constant (32 molecules), heat capacity at constant pressure (three molecules), and the isothermal compressibility (53 molecules) as a function of the temperature have been made, based on experimental data, in order to be able to compare simulation results to them. To compute the heat capacities, we applied the two phase thermodynamics method (Lin et al. J. Chem. Phys.2003, 119, 11792), which allows one to compute thermodynamic properties on the basis of the density of states as derived from the velocity autocorrelation function. The method is implemented in a new utility within the GROMACS molecular simulation package, named g_dos, and a detailed exposé of the underlying equations is presented. The purpose of this work is to establish the state of the art of two popular force fields, OPLS/AA (all-atom optimized potential for liquid simulation) and GAFF (generalized Amber force field), to find common bottlenecks, i.e., particularly difficult molecules, and to serve as a reference point for future force field development. To make for a fair playing field, all molecules were evaluated with the same parameter settings, such as thermostats and barostats

  18. Effect of nanoparticles on heat capacity of nanofluids based on molten salts as PCM for thermal energy storage

    Science.gov (United States)

    Chieruzzi, Manila; Cerritelli, Gian F.; Miliozzi, Adio; Kenny, José M.

    2013-10-01

    In this study, different nanofluids with phase change behavior were developed by mixing a molten salt base fluid (selected as phase change material) with nanoparticles using the direct-synthesis method. The thermal properties of the nanofluids obtained were investigated. These nanofluids can be used in concentrating solar plants with a reduction of storage material if an improvement in the specific heat is achieved. The base salt mixture was a NaNO3-KNO3 (60:40 ratio) binary salt. The nanoparticles used were silica (SiO2), alumina (Al2O3), titania (TiO2), and a mix of silica-alumina (SiO2-Al2O3). Three weight fractions were evaluated: 0.5, 1.0, and 1.5 wt.%. Each nanofluid was prepared in water solution, sonicated, and evaporated. Measurements on thermophysical properties were performed by differential scanning calorimetry analysis and the dispersion of the nanoparticles was analyzed by scanning electron microscopy (SEM). The results obtained show that the addition of 1.0 wt.% of nanoparticles to the base salt increases the specific heat of 15% to 57% in the solid phase and of 1% to 22% in the liquid phase. In particular, this research shows that the addition of silica-alumina nanoparticles has a significant potential for enhancing the thermal storage characteristics of the NaNO3-KNO3 binary salt. These results deviated from the predictions of the theoretical model used. SEM suggests a greater interaction between these nanoparticles and the salt.

  19. The high-temperature heat capacity of the (Th,U)O2 and (U,Pu)O2 solid solutions

    Science.gov (United States)

    Vălu, S. O.; Beneš, O.; Manara, D.; Konings, R. J. M.; Cooper, M. W. D.; Grimes, R. W.; Guéneau, C.

    2017-02-01

    The enthalpy increment data for the (Th,U)O2 and (U,Pu)O2 solid solutions are reviewed and complemented with new experimental data (400-1773 K) and many-body potential model simulations. The results of the review show that from room temperature up to about 2000 K the enthalpy data are in agreement with the additivity rule (Neumann-Kopp) in the whole composition range. Above 2000 K the effect of Oxygen Frenkel Pair (OFP) formation leads to an excess enthalpy (heat capacity) that is modeled using the enthalpy and entropy of OFP formation from the end-members. A good agreement with existing experimental work is observed, and a reasonable agreement with the results of the many-body potential model, which indicate the presence of the diffuse Bredig (superionic) transition that is not found in the experimental enthalpy increment data.

  20. The electronic heat capacity of YBa{sub 2}Cu{sub 3}O{sub 7−δ} superconductor

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Anu, E-mail: anuiiser@gmail.com; Singh, Hempal; Indu, B. D., E-mail: drbdindu@gmail.com [Department of Physics, Indian Institute of Technology Roorkee 247667, Uttarakhand (India)

    2016-07-15

    The contributions due to the point defects or disorder and anharmonicities which play deterministic role in the understanding of electronic heat capacity (EHC) of high temperature superconductors (HTS) have been investigated via electron density of states (EDOS) approach on the basis of quantum dynamical many body theory. The evaluation of EDOS has been carried out with the help of most versatile method of double time temperature dependent electron Green’s functions (GF) via a Hamiltonian (non BCS type) which includes the effects of electrons, phonons, defects, anharmonicity, and electron-phonon interactions which enables to account the effects of cubic anharmonicity besides with both the force constant changes and mass difference caused by the impurities in developing the results for EDOS and EHC. The new results reveal some striking features of EHC of HTS.

  1. Tipping a SPRUCE tree over - how extreme heat and desiccation may push southern boreal species beyond their capacity

    Science.gov (United States)

    Warren, J.; Childs, J.; Ward, E. J.; Wullschleger, S.; Hanson, P. J.

    2016-12-01

    Since August 2015, the Spruce and Peatland Responses under Climatic and Environmental Change (SPRUCE) climate change experiment (http://mnspruce.ornl.gov/) in Northern Minnesota, USA, has exposed 13 m diameter plots of an ombrotrophic Picea mariana - Ericaceous shrub - Sphagnum bog ecosystem to long-term temperature (T) (0 to +9 °C) and since June 2016, elevated CO2 treatments (ambient or + 500 ppm). In addition to their direct impacts, the T and CO2 treatments have dramatically impacted soil water availability, vapor pressure deficit and # days dew point is reached. We examined plant water relations of Picea mariana (black spruce), Larix laricina (tamarack), and several Ericaceous shrubs including seasonal patterns of water potential (ψ), in addition to sap flow in the in trees. Granier-style thermal dissipation sensors were calibrated in situ (outside plots) by cutting instrumented trees and measuring their actual water uptake. Maximum summer T in N Minnesota reaches 35 °C, and optimal photosynthetic activity for P. mariana at the site peaks between 35-38°C. Treatments have resulted in air T reaching 45°C in the warmest plots resulting in substantial physiological stress. Pretreatment sap flow typically began by late May and was fairly constant over the season until declining in mid-September and ceasing as temperatures dropped below zero. Once the T treatments began, sap flow began earlier in the spring and continued later in the fall indicating an expanded physiological season that can result in plant vulnerability to extreme cold events. Indeed, foliar damage was evident in warmer plots following a spring freeze event in 2016. In addition, the drying heat has resulted in additional foliar damage, indicated by large reductions in predawn water potentials (even in the spring), quicker drying following rain events, and water stress reached earlier in the day. Midday mean summer ψ was -1.5 MPa for P. mariana foliage, higher than the co-occurring L. laricina

  2. Systematic Studies on Anharmonicity of Rattling Phonons in Type I Clathrates by Low Temperature Heat Capacity Measurements

    Science.gov (United States)

    Tanigaki, Katsumi; Wu, Jiazhen; Tanabe, Yoichi; Heguri, Satoshi; Shiimotani, Hidekazu; Tohoku University Collaboration

    2014-03-01

    Clathrates are featured by cage-like polyhedral hosts mainly composed of the IVth group elements of Si, Ge, or Sn and alkali metal or alkaline-earth metal elements can be accommodated inside as a guest atom. One of the most intriguing issues in clathrates is their outstanding high thermoelectric performances thanks to the low thermal conductivity. Being irrespective of good electric conductivity σ, the guest atom motions provide a low-energy lying less-dispersive phonons and can greatly suppress thermal conductivity κ. This makes clathrates close to the concept of ``phonon glass electron crystal: PGEC'' and useful in thermoelectric materials from the viewpoint of the figure of merit. In the present study, we show that the local phonon anharmonicity indicated by the tunneling-term of the endohedral atoms (αT) and the itinerant-electron term (γeT), both of which show T-linear dependences in specific heat Cp, can successfully be separated by employing single crystals with various carrier concentrations in a wide range of temperture experimennts. The factors affecting on the phonon anharmonicity as well as the strength of electron-phonon interactions will be discussed based on our recent experiments. The research was financially supported by Ministry of Education, Science, Sports and Culture, Grant in Aid for Science, and Technology of Japan.

  3. Alternating current calorimeter for specific heat capacity measurements at temperatures below 10 K and pressures up to 10 GPa

    Energy Technology Data Exchange (ETDEWEB)

    Umeo, Kazunori, E-mail: kumeo@sci.hiroshima-u.ac [Cryogenics and Instrumental Analysis Division, N-BARD, Hiroshima University, Kagamiyama 1-3-1, Higashi-Hiroshima 739-8526 (Japan)

    2016-06-15

    A developed alternating current calorimeter for measuring the absolute value of specific heat C of a very small sample under a pressure up to 10 GPa and low temperature below 10 K is described. A Bridgman anvil cell made of tungsten carbide with a top diameter of 3 mm is used. A hollow at the top prevents expansion of the sample space over the anvil top. Two chip resistors, which act as a thermometer and a heater, are mounted on the outer part of a copper–beryllium gasket with a frying pan-like shape. Thus, the thermometer is not pressurized. In order to isolate the gasket from the anvil thermally, diamond powder with a grain size of 0.25 μm is placed on the anvil top. Two jumps of C at the superconducting transitions of Pb (3.3 mg) and In (5.0 mg) are observed under various pressures up to 9 GPa, as clearly as those at the ambient pressure.

  4. Anharmonic phonon quasiparticle theory of zero-point and thermal shifts in insulators: Heat capacity, bulk modulus, and thermal expansion

    Science.gov (United States)

    Allen, Philip B.

    2015-08-01

    The quasiharmonic (QH) approximation uses harmonic vibrational frequencies ωQ ,H(V ) computed at volumes V near V0 where the Born-Oppenheimer (BO) energy Eel(V ) is minimum. When this is used in the harmonic free energy, QH approximation gives a good zeroth order theory of thermal expansion and first-order theory of bulk modulus, where nth-order means smaller than the leading term by ɛn, where ɛ =ℏ ωvib/Eel or kBT /Eel , and Eel is an electronic energy scale, typically 2 to 10 eV. Experiment often shows evidence for next-order corrections. When such corrections are needed, anharmonic interactions must be included. The most accessible measure of anharmonicity is the quasiparticle (QP) energy ωQ(V ,T ) seen experimentally by vibrational spectroscopy. However, this cannot just be inserted into the harmonic free energy FH. In this paper, a free energy is found that corrects the double-counting of anharmonic interactions that is made when F is approximated by FH( ωQ(V ,T ) ) . The term "QP thermodynamics" is used for this way of treating anharmonicity. It enables (n +1 ) -order corrections if QH theory is accurate to order n . This procedure is used to give corrections to the specific heat and volume thermal expansion. The QH formulas for isothermal (BT) and adiabatic (BS) bulk moduli are clarified, and the route to higher-order corrections is indicated.

  5. An automated flow calorimeter for heat capacity and enthalpy measurements at elevated temperatures and pressures: Progress report, March 1, 1987-February 29, 1988

    Energy Technology Data Exchange (ETDEWEB)

    Yesavage, V.F.

    1987-10-01

    The need for thermal property data at process conditions in the design of petrochemical and synfuel plants has been well documented. As such, the primary objective of this work is to construct an automated flow calorimeter to measure isobaric heat capacities and enthalpies of vaporization over the range 0 to 30MPa and 300 to 700K with an anticipated accuracy of 0.1%. The method of measurement is by the traditional electrical power input technique with a unique calorimeter design utilizing a concentric coil/radiation shield structure which minimizes heat loss errors and simplifies the replacement of plugged components. Flow generation is accomplished with a precision Ruska pump eliminating the need for on-line flow rate measurement. In addition, the proposed instrument will be fully automated minimizing the need for highly skilled operators which had previously been a severe limitation with this type of instrument. Significant progress has been made on the project this last year with the completion of construction of all major system hardware components and the associated automation electronics. Initial tests of the equipment are encouraging and no significant delays are foreseen in the completion of the apparatus. During the next year the automation and data acquisition software will be written and the completed unit will be tested with water. 7 figs.

  6. Effect of Heat Treatment on the Nitrogen Content and Its Role on the Carbon Dioxide Adsorption Capacity of Highly Ordered Mesoporous Carbon Nitride.

    Science.gov (United States)

    Lakhi, Kripal S; Park, Dae-Hwan; Joseph, Stalin; Talapaneni, Siddulu N; Ravon, Ugo; Al-Bahily, Khalid; Vinu, Ajayan

    2017-03-02

    Mesoporous carbon nitrides (MCNs) with rod-shaped morphology and tunable nitrogen contents have been synthesized through a calcination-free method by using ethanol-washed mesoporous SBA-15 as templates at different carbonization temperatures. Carbon tetrachloride and ethylenediamine were used as the sources of carbon and nitrogen, respectively. The resulting MCN materials were characterized with low- and high-angle powder XRD, nitrogen adsorption, high-resolution (HR) SEM, HR-TEM, elemental analysis, X-ray photoelectron spectroscopy, and X-ray absorption near-edge structure techniques. The carbonization temperature plays a critical role in controlling not only the crystallinity, but also the nitrogen content and textural parameters of the samples, including specific surface area and specific pore volume. The nitrogen content of MCN decreases with a concomitant increase in specific surface area and specific pore volume, as well as the crystallinity of the samples, as the carbonization temperature is increased. The results also reveal that the structural order of the materials is retained, even after heat treatment at temperatures up to 900 °C with a significant reduction of the nitrogen content, but the structure is partially damaged at 1000 °C. The carbon dioxide adsorption capacity of these materials is not only dependent on the textural parameters, but also on the nitrogen content. The MCN prepared at 900 °C, which has an optimum BET surface area and nitrogen content, registers a carbon dioxide adsorption capacity of 20.1 mmol g(-1) at 273 K and 30 bar, which is much higher than that of mesoporous silica, MCN-1, activated carbon, and multiwalled carbon nanotubes. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Spin- and valley-dependent electronic band structure and electronic heat capacity of ferromagnetic silicene in the presence of strain, exchange field and Rashba spin-orbit coupling

    Science.gov (United States)

    Hoi, Bui Dinh; Yarmohammadi, Mohsen; Kazzaz, Houshang Araghi

    2017-10-01

    We studied how the strain, induced exchange field and extrinsic Rashba spin-orbit coupling (RSOC) enhance the electronic band structure (EBS) and electronic heat capacity (EHC) of ferromagnetic silicene in presence of external electric field (EF) by using the Kane-Mele Hamiltonian, Dirac cone approximation and the Green's function approach. Particular attention is paid to investigate the EHC of spin-up and spin-down bands at Dirac K and K‧ points. We have varied the EF, strain, exchange field and RSOC to tune the energy of inter-band transitions and consequently EHC, leading to very promising features for future applications. Evaluation of EF exhibits three phases: Topological insulator (TI), valley-spin polarized metal (VSPM) and band insulator (BI) at given aforementioned parameters. As a new finding, we have found a quantum anomalous Hall phase in BI regime at strong RSOCs. Interestingly, the effective mass of carriers changes with strain, resulting in EHC behaviors. Here, exchange field has the same behavior with EF. Finally, we have confirmed the reported and expected symmetry results for both Dirac points and spins with the study of valley-dependent EHC.

  8. Spin heat capacity of monolayer and AB-stacked bilayer MoS2 in the presence of exchange magnetic field

    Science.gov (United States)

    Hoi, Bui Dinh; Yarmohammadi, Mohsen; Mirabbaszadeh, Kavoos

    2017-04-01

    Dirac theory and Green's function technique are carried out to compute the spin dependent band structures and corresponding electronic heat capacity (EHC) of monolayer (ML) and AB-stacked bilayer (BL) molybdenum disulfide (MoS2) two-dimensional (2D) crystals. We report the influence of induced exchange magnetic field (EMF) by magnetic insulator substrates on these quantities for both structures. The spin-up (down) subband gaps are shifted with EMF from conduction (valence) band to valence (conduction) band at both Dirac points in the ML because of the spin-orbit coupling (SOC) which leads to a critical EMF in the K point and EHC returns to its initial states for both spins. In the BL case, EMF results split states and the decrease (increase) behavior of spin-up (down) subband gaps has been observed at both K and K‧ valleys which is due to the combined effect of SOC and interlayer coupling. For low and high EMFs, EHC of BL MoS2 does not change for spin-up subbands while increases for spin-down subbands.

  9. Heat Capacity and Thermal Conductance Measurements of a Superconducting-Normal Mixed State by Detection of Single 3 eV Photons in a Magnetic Penetration Thermometer

    Science.gov (United States)

    Stevenson, T. R.; Balvin, M. A.; Bandler, S. R.; Denis, K. L.; Lee, S.-J.; Nagler, P. C.; Smith, S. J.

    2015-01-01

    We report on measurements of the detected signal pulses in a molybdenum-gold Magnetic Penetration Thermometer (MPT) in response to absorption of one or more 3 eV photons. We designed and used this MPT sensor for x-ray microcalorimetry. In this device, the diamagnetic response of a superconducting MoAu bilayer is used to sense temperature changes in response to absorbed photons, and responsivity is enhanced by a Meissner transition in which the magnetic flux penetrating the sensor changes rapidly to minimize free energy in a mixed superconducting normal state. We have previously reported on use of our MPT to study a thermal phonon energy loss to the substrate when absorbing x-rays. We now describe results of extracting heat capacity C and thermal conductance G values from pulse height and decay time of MPT pulses generated by 3 eV photons. The variation in C and G at temperatures near the Meissner transition temperature (set by an internal magnetic bias field) allow us to probe the behavior in superconducting normal mixed state of the condensation energy and the electron cooling power resulting from quasi-particle recombination and phonon emission. The information gained on electron cooling power is also relevant to the operation of other superconducting detectors, such as Microwave Kinetic Inductance Detectors.

  10. A comprehensive assessment of geographic variation in heat tolerance and hardening capacity in populations of Drosophila melanogaster from eastern Australia

    DEFF Research Database (Denmark)

    Sgrò, C M; Overgaard, J; Kristensen, T N

    2010-01-01

    We examined latitudinal variation in adult and larval heat tolerance in Drosophila melanogaster from eastern Australia. Adults were assessed using static and ramping assays. Basal and hardened static heat knockdown time showed significant linear clines; heat tolerance increased towards the tropics......, particularly for hardened flies, suggesting that tropical populations have a greater hardening response. A similar pattern was evident for ramping heat knockdown time at 0.06 °C min-1 increase. There was no cline for ramping heat knockdown temperature (CTmax) at 0.1 °C min-1 increase. Acute (static) heat...

  11. Correcting for heat capacity and 5'-TA type terminal nearest neighbors improves prediction of DNA melting temperatures using nearest-neighbor thermodynamic models.

    Science.gov (United States)

    Hughesman, Curtis B; Turner, Robin F B; Haynes, Charles

    2011-04-05

    Nearest-neighbor thermodynamic (NNT) models currently provide some of the most accurate predictions of melting thermodynamics, including melting temperature (T(m)) values, for short DNA duplexes. Inherent to all existing NNT models is the assumption that ΔH° and ΔS° for the helix-to-coil transition are temperature invariant. Here we investigate the impact that this zero-ΔC(p) assumption has on the accuracy of T(m) predictions for 128 DNA duplexes. Previous and new melting thermodynamic data are analyzed to establish an estimate of ΔC(p)(bp), the heat capacity change per base pair, of 42 ± 16 cal mol(-1) K(-1) bp(-1), as well as an optimal thermodynamic reference temperature (T(ref)) of 53 ± 5 °C. These results were used to modify the unified NNT model to properly account for the temperature dependence of ΔH° and ΔS° and thereby extend the range over which T(m) is accurately predicted. This new approach is shown to be especially useful for duplexes that melt at a T(m) greater than 70 °C. Thermodynamic data collected by differential scanning calorimetry (DSC) for 16 duplexes designed to melt over a broad temperature range were used to verify the values of ΔC(p)(bp) and T(ref) and to show that ΔC(p)(bp) is essentially constant above 37 °C. Additional DSC analysis of 12 duplex sequences containing all 10 nearest neighbors allowed for errors associated with different terminal nearest neighbors to be examined and showed that duplexes containing one or more terminal 5'-TA groups are significantly more stable than predicted by the unified NNT model. A correction to improve prediction of the hybridization thermodynamics of duplexes with terminal 5'-TA groups is provided.

  12. Solvation molar enthalpies and heat capacities of n-alkanes and n-alkylbenzenes on stationary phases of wide-ranging polarity.

    Science.gov (United States)

    Lebrón-Aguilar, Rosa; Quintanilla-López, Jesús Eduardo; Santiuste, José María

    2010-12-03

    A comparison of the most usual gas chromatographic methods for the calculation of partial molar enthalpies of solvation (Δ(sol)H(o)) has been carried out. Those methods based on the fitting of lnV(g) or ln(k/T) vs. 1/T and ln(k/T) vs. (1/T and the temperature arrangement, T(a)) are the most adequate ones for obtaining Δ(sol)H(o) values. However, the latter is the only reliable option for Δ(sol)H(o) estimation when commercial WCOT capillary columns are used, since in this case the estimation of some variables involved in the V(g) determination is less accurate or even impossible. Consequently, in this paper, Δ(sol)H(o) obtained from ln(k/T) vs. (1/T+T(a)) fitting at 373.15 and 298.15K for n-alkanes and n-alkylbenzenes on 12 commercial capillary columns coated with stationary phases covering the 203-3608 McReynolds polarity range are reported. Moreover, molar heat capacities of solvation at constant pressure (Δ(sol)C(p)(o)) have also been calculated using this method. A clear influence on Δ(sol)H(o) of the type and content of the substitution group in the stationary phase was observed. In addition, a linear relationship of Δ(sol)C(p)(o) with the van der Waals volume of the n-alkanes and the temperature gradient of density of the stationary phase was found. The effect of the size of the hydrocarbon on both thermodynamic variables was also investigated. Copyright © 2010 Elsevier B.V. All rights reserved.

  13. Improved methods for Feynman path integral calculations and their application to calculate converged vibrational-rotational partition functions, free energies, enthalpies, entropies, and heat capacities for methane.

    Science.gov (United States)

    Mielke, Steven L; Truhlar, Donald G

    2015-01-28

    We present an improved version of our "path-by-path" enhanced same path extrapolation scheme for Feynman path integral (FPI) calculations that permits rapid convergence with discretization errors ranging from O(P(-6)) to O(P(-12)), where P is the number of path discretization points. We also present two extensions of our importance sampling and stratified sampling schemes for calculating vibrational-rotational partition functions by the FPI method. The first is the use of importance functions for dihedral angles between sets of generalized Jacobi coordinate vectors. The second is an extension of our stratification scheme to allow some strata to be defined based only on coordinate information while other strata are defined based on both the geometry and the energy of the centroid of the Feynman path. These enhanced methods are applied to calculate converged partition functions by FPI methods, and these results are compared to ones obtained earlier by vibrational configuration interaction (VCI) calculations, both calculations being for the Jordan-Gilbert potential energy surface. The earlier VCI calculations are found to agree well (within ∼1.5%) with the new benchmarks. The FPI partition functions presented here are estimated to be converged to within a 2σ statistical uncertainty of between 0.04% and 0.07% for the given potential energy surface for temperatures in the range 300-3000 K and are the most accurately converged partition functions for a given potential energy surface for any molecule with five or more atoms. We also tabulate free energies, enthalpies, entropies, and heat capacities.

  14. Experimental determination of the high temperature heat capacity of a natural xenotime-(Y) solid solution and synthetic DyPO{sub 4} and ErPO{sub 4} endmembers

    Energy Technology Data Exchange (ETDEWEB)

    Gysi, Alexander P., E-mail: agysi@mines.edu [Department of Geology and Geological Engineering, Colorado School of Mines, 1516 Illinois Street, Golden, CO 80401 (United States); Harlov, Daniel [Geoforschungszentrum Potsdam (GFZ), Telegrafenberg, D-14473 Potsdam (Germany); Filho, Deusavan Costa [Department of Geology and Geological Engineering, Colorado School of Mines, 1516 Illinois Street, Golden, CO 80401 (United States); Williams-Jones, Anthony E. [Department of Earth and Planetary Sciences, McGill University, 3450 University St., Montreal, QC H3A 2A7 (Canada)

    2016-03-20

    Highlights: • A new DSC calibration method for minerals of geological interest is described. • The heat capacity of DyPO{sub 4}, ErPO{sub 4} and xenotime-(Y) were reliably determined using DSC. • The excess heat capacity of xenotime-(Y) indicates a non-ideal solution with other HREE. - Abstract: The heat capacity of natural xenotime-(Y) and synthetic DyPO{sub 4} and ErPO{sub 4} crystals was determined by differential scanning calorimetry (DSC) at temperatures of 298.15 K to 868.15 K and a pressure of 0.1 MPa. The aim of the study was to develop a method to accurately measure the isobaric heat capacity (C{sub P}) of rare earth element (REE) phosphates, compare the results to data from adiabatic calorimetric experiments, and evaluate the deviation from ideality of the C{sub P} of the natural xenotime-(Y) solid solution. The measured C{sub P} data (in J mol{sup −1} K{sup −1}) can be described by the relationships: 185.5 − 751.9T{sup −0.5} − 3.261e + 06 T{sup −2} for DyPO{sub 4}; 207.2 − 1661T{sup −0.5} − 5.289e + 05 T{sup −2} for ErPO{sub 4}; and 208 − 1241T{sup −0.5} − 2.493e + 06 T{sup −2} for xenotime-(Y); where T is the temperature in K. The heat capacity data for natural xenotime-(Y) were used to determine the excess function for the solid solution, which yields an excess heat capacity ranging between 7.9 and 10.7%, well within the range of the DSC method used in this study. The experiments indicate that xenotime-(Y) forms a non-ideal solid solution. Future DSC studies will provide important data for developing a solid solution model for the incorporation of REE in xenotime-(Y).

  15. Hemispherical total emissivity and specific heat capacity of deeply undercooled Zr41.2Ti13.8Cu12.5Ni10.0Be22.5 melts

    Science.gov (United States)

    Busch, R.; Kim, Y. J.; Johnson, W. L.; Rulison, A. J.; Rhim, W. K.; Isheim, D.

    1995-06-01

    High-temperature high-vacuum electrostatic levitation (HTHVESL) and differential scanning calorimetry (DSC) were combined to determine the hemispherical total emissivity ɛT, and the specific heat capacity cp, of the undercooled liquid and throughout the glass transition of the Zr41.2Ti13.8Cu12.5Ni10.0Be22.5 bulk metallic glass forming alloy. The ratio of cp/ɛT as a function of undercooling was determining from radiative cooling curves measured in the HTHVESL. Using specific heat capacity data obtained by DSC investigations close to the glass transition and above the melting point, ɛT and cp were separated and the specific heat capacity of the whole undercooled liquid region was determined. Furthermore, the hemispherical total emissivity of the liquid was found to be about 0.22 at 980 K. On undercooling the liquid, the emissivity decreases to approximately 0.18 at about 670 K, where the undercooled liquid starts to freeze to a glass. No significant changes of the emissivity are observed as the alloy undergoes the glass transition.

  16. Interlaboratory study of the heat capacity of LiNi{sub 1/3}Mn{sub 1/3}Co{sub 1/3}O{sub 2} (NMC111) with layered structure

    Energy Technology Data Exchange (ETDEWEB)

    Cupid, Damian M.; Gotcu, Petronela [Karlsruhe Institute of Technology (KIT), Eggenstein-Leopoldshafen (Germany). Inst. for Applied Materials - Applied Materials Physics (IAM-AWP); Beutl, Alexander [Vienna Univ. (Austria). Inst. of Inorganic Chemistry - Functional Materials; and others

    2017-11-15

    An interlaboratory study was performed to determine the heat capacity of an active material for lithium-ion batteries with layered structure and nominal composition LiNi{sub 1/3} . Mn{sub 1/3}Co{sub 1/3}O{sub 2} (NMC111). The commercial sample, which was characterized using powder X-ray diffraction and inductively coupled plasma-optical emission spectroscopy, is single phase (α-NaFeO{sub 2} crystal structure) with a composition of Li{sub 1.02}Ni{sub 0.32}Mn{sub 0.31}Co{sub 0.30}O{sub 2}. Heat capacity measurements of the homogeneous sample were performed at five laboratories using different operators, methods, devices, temperature ranges, gas atmospheres and crucible materials. The experimental procedures from each laboratory are presented and the results of the individual laboratories are analyzed. Based on a comprehensive evaluation of the data from each laboratory, the heat capacity of the NMC111 sample from 315 K to 1 020 K is obtained with an expanded reproducibility uncertainty of less than 1.22 %.

  17. Public utility Rosenheim enlarge the capacity of district heating by means of return temperatures. District heating transmission stations with cascade; Stadtwerke Rosenheim erweitern FW-Kapazitaet durch niedrigere Ruecklauftemperaturen. Fernwaermeuebergabestation mit Kaskade

    Energy Technology Data Exchange (ETDEWEB)

    Bruehl, Goetz; Bielmeier, Reinhard; Neugebauer, Horst [Stadtwerke Rosenheim (Germany); Weinmann, Edwin [Planungsbuero Weinmann, Muenchen (Germany); Planungsbuero Weinmann, Wielenbach (Germany)

    2012-12-15

    In most cases heating systems, drinking water heaters and circulation heaters are connected in parallel. This arrangement often results in too high return temperatures. In order to keep down the return temperature all the year, the public utility Rosenheim developed a cascaded high-efficiency district heating transmission station in cooperation with two partners. Due to the series connection of the heat exchangers for the hot water circulation, the heating system and the drinking water heaters in continuous flow, not only permanently lower return temperatures are achieved, but also the consumption of the power of pumps is lowered as well as the hygiene requirements to drinking water is improved.

  18. Characteristics of cold-forming steels for district heating systems. Connection of low-capacity systems; Besonderheiten kaltumformbarer Staehle fuer den Fernwaermeleitungsbau. Anschluss kleiner Waermeleistungen

    Energy Technology Data Exchange (ETDEWEB)

    Wolf, Ingo [Enercity Netzgesellschaft mbH, Hannover (Germany)

    2011-10-15

    There is still great potential in the connection of low capacity systems. A project was therefore initiated which is to provide information for optimum implementation of low-capacity household systems. The investigations focussed on the flexible plastic jacket tube 'Stahlflex'. Among others, it was investigated whether bending of steel tubes with longitudinal welds will cause cold solidification or cracking. Bending moments, thermal treatment, alloying elements and tube geometry were gone into as well.

  19. Cryogenic heat transfer

    CERN Document Server

    Barron, Randall F

    2016-01-01

    Cryogenic Heat Transfer, Second Edition continues to address specific heat transfer problems that occur in the cryogenic temperature range where there are distinct differences from conventional heat transfer problems. This updated version examines the use of computer-aided design in cryogenic engineering and emphasizes commonly used computer programs to address modern cryogenic heat transfer problems. It introduces additional topics in cryogenic heat transfer that include latent heat expressions; lumped-capacity transient heat transfer; thermal stresses; Laplace transform solutions; oscillating flow heat transfer, and computer-aided heat exchanger design. It also includes new examples and homework problems throughout the book, and provides ample references for further study.

  20. Dielectric and magnetic properties of NiFe{sub 2}O{sub 4} at 2.45 GHz and heating capacity for potential uses under microwaves

    Energy Technology Data Exchange (ETDEWEB)

    Polaert, Isabelle, E-mail: isabelle.polaert@insa-rouen.fr [LSPC (Laboratoire de Sécurité des Procédés Chimiques). Institut National des Sciences Appliquées INSA Rouen (France); Bastien, Samuel [Département de génie chimique et de génie biotechnologique, Université de Sherbrooke, Sherbrooke, Québec, Canada J1K 2R1 (Canada); Legras, Benoit [LSPC (Laboratoire de Sécurité des Procédés Chimiques). Institut National des Sciences Appliquées INSA Rouen (France); Département de génie chimique et de génie biotechnologique, Université de Sherbrooke, Sherbrooke, Québec, Canada J1K 2R1 (Canada); Estel, Lionel [LSPC (Laboratoire de Sécurité des Procédés Chimiques). Institut National des Sciences Appliquées INSA Rouen (France); Braidy, Nadi [Département de génie chimique et de génie biotechnologique, Université de Sherbrooke, Sherbrooke, Québec, Canada J1K 2R1 (Canada)

    2015-01-15

    This paper presents the dielectric and magnetic properties, measured at 2.45 GHz, of a new nickel ferrite, NiFe{sub 2}O{sub 4}, synthetized by plasma technology. These properties were measured by the small perturbation method in a resonant cavity, from 293 to 513 K. Using these values, the adiabatic heating of nanoparticles of NiFe{sub 2}O{sub 4} under microwave irradiation was also modeled. The wave propagation equation (Maxwell's equation) coupled to the heat transfer in the solid was numerically solved. The influence of parameters such as the bed volume, its porosity, the microwave incident power or the microwave system geometry is discussed. This study demonstrates that NiFe{sub 2}O{sub 4} nanoparticles can be rapidly heated up to at least 513 K under microwaves and can probably achieve higher temperatures according to the thermal insulation. The magnetic contribution to heating overcomes the dielectric one in the explored temperature range. Very efficient energy yield (>90%) can then be achieved when the magnetic field position is centered over the bed. - Highlights: • A new nickel ferrite, NiFe{sub 2}O{sub 4}, was synthetized by plasma technology. • Its dielectric and magnetic properties were measured at 2.45 GHz. • The adiabatic heating of nanoparticles of NiFe{sub 2}O{sub 4} under microwave was modeled. • NiFe{sub 2}O{sub 4} nanoparticles can be rapidly heated up to at least 513 K. • The magnetic contribution to heating overcomes the dielectric one from 293 K to 513 K.

  1. The temperature response of CO2 assimilation, photochemical activities and Rubisco activation in Camelina sativa, a potential bioenergy crop with limited capacity for acclimation to heat stress.

    Science.gov (United States)

    Carmo-Silva, A Elizabete; Salvucci, Michael E

    2012-11-01

    The temperature optimum of photosynthesis coincides with the average daytime temperature in a species' native environment. Moderate heat stress occurs when temperatures exceed the optimum, inhibiting photosynthesis and decreasing productivity. In the present study, the temperature response of photosynthesis and the potential for heat acclimation was evaluated for Camelina sativa, a bioenergy crop. The temperature optimum of net CO(2) assimilation rate (A) under atmospheric conditions was 30-32 °C and was only slightly higher under non-photorespiratory conditions. The activation state of Rubisco was closely correlated with A at supra-optimal temperatures, exhibiting a parallel decrease with increasing leaf temperature. At both control and elevated temperatures, the modeled response of A to intercellular CO(2) concentration was consistent with Rubisco limiting A at ambient CO(2). Rubisco activation and photochemical activities were affected by moderate heat stress at lower temperatures in camelina than in the warm-adapted species cotton and tobacco. Growth under conditions that imposed a daily interval of moderate heat stress caused a 63 % reduction in camelina seed yield. Levels of cpn60 protein were elevated under the higher growth temperature, but acclimation of photosynthesis was minimal. Inactivation of Rubisco in camelina at temperatures above 35 °C was consistent with the temperature response of Rubisco activase activity and indicated that Rubisco activase was a prime target of inhibition by moderate heat stress in camelina. That photosynthesis exhibited no acclimation to moderate heat stress will likely impact the development of camelina and other cool season Brassicaceae as sources of bioenergy in a warmer world.

  2. Station Capacity

    DEFF Research Database (Denmark)

    Landex, Alex

    2011-01-01

    Stations are often limiting the capacity of railway networks. This is due to extra need of tracks when trains stand still, trains turning around, and conflicting train routes. Although stations are often the capacity bottlenecks, most capacity analysis methods focus on open line capacity. Therefore......, this paper presents methods to analyze station capacity. Four methods to analyze station capacity are developed. The first method is an adapted UIC 406 capacity method that can be used to analyze switch zones and platform tracks at stations that are not too complex. The second method examines the need...... the probability of conflicts and the minimum headway times into account. The last method analyzes how optimal platform tracks are used by examining the arrival and departure pattern of the trains. The developed methods can either be used separately to analyze specific characteristics of the capacity of a station...

  3. High-Performance Heat Pipe

    Science.gov (United States)

    Alario, J. P.; Kosson, R.; Haslett, R.

    1985-01-01

    Single vapor channel and single liquid channel joined by axial slot. New design, permits high heat-transport capacity without excessively reducing heat-transfer efficiency. Contains two large axial channels, one for vapor and one for liquid, permitting axial transport and radial heat-transfer requirements met independently. Heat pipe has capacity of approximately 10 to sixth power watt-inches (2.5 X 10 to sixth power watt-cm) orders of magnitude greater than heat capacity of existing heat pipes. Design has high radial-heat-transfer efficiency, structurally simple, and has large liquid and vapor areas.

  4. High Capacity, Superior Cyclic Performances in All-Solid-State Lithium-Ion Batteries Based on 78Li2S-22P2S5 Glass-Ceramic Electrolytes Prepared via Simple Heat Treatment.

    Science.gov (United States)

    Zhang, Yibo; Chen, Rujun; Liu, Ting; Shen, Yang; Lin, Yuanhua; Nan, Ce-Wen

    2017-08-30

    Highly Li-ion conductive 78Li2S-22P2S5 glass-ceramic electrolytes were prepared by simple heat treatment of the glass phase obtained via mechanical ball milling. A high ionic conductivity of ∼1.78 × 10(-3) S cm(-1) is achieved at room temperature and is attributed to the formation of a crystalline phase of high lithium-ion conduction. All-solid-state lithium-ion batteries based on these glass-ceramic electrolytes are assembled by using Li2S nanoparticles or low-cost commercially available FeS2 as active cathode materials and Li-In alloys as anode. A high discharge capacity of 535 mAh g(-1) is achieved after at least 50 cycles for the all-solid-state cells with Li2S as cathode materials, suggesting a rather high capacity retention of 97.4%. Even for the cells using low-cost FeS2 as cathode materials, same high discharge capacity of 560 mAh g(-1) is also achieved after at least 50 cycles. Moreover, the Coulombic efficiency remain at ∼99% for these all-solid-state cells during the charge-discharge cycles.

  5. Using TOPEX Satellite El Niño Altimetry Data to Introduce Thermal Expansion and Heat Capacity Concepts in Chemistry Courses

    Science.gov (United States)

    Blanck, Harvey F.

    1999-12-01

    extremely complex system. The Gaussian model proposed for the cross section of a warm-water ridge requires more study, but it is a useful visual model of the warm-water bump above the normal surface and its subsurface warm-water wedge. I believe students will enjoy these relevant calculations and learn a bit about density, thermal expansion, and heat capacity in the process. I have tried to present sufficient data and detail to allow teachers to pick and choose calculations appropriate to the level of their students. It is evident that dimensional analysis is a distinct advantage in using these equations. I have also tried to include enough descriptive detail of the TOPEX data and El Niño to answer many of the questions students may ask. The Web sites mentioned are very informative with both text and graphics. Figure 2. General appearance of the cross section of a warm water ridge of excess sea surface height and the subsurface warm water. The subsurface curve is the warm water/thermocline boundary. Because of a large difference between the size of the warm water portion above and below the normal surface, two different scales have been used. Acknowledgments The data for the cells and the pictorial representation of the relative TOPEX altimetry data of the Pacific basin were very kindly provided by the TOPEX/Poseidon Project conducted by the Jet Propulsion Laboratory of the California Institute of Technology under contract with NASA. I wish to specifically thank JPL scientists Akiko Hayashi and Lee-Lueng Fu for providing data and I especially thank JPL scientist Victor Zlotnicki for helpful comments and suggestions. Several reviewers made helpful suggestions, which were very much appreciated. Literature Cited 1. NOAA's Pacific Marine Environmental Laboratory (PMEL) Web site; http://www.pmel.noaa.gov and especially http://www.pmel.noaa.gov/toga-tao/realtime.html (accessed Sep 1999). 2. Chambers, D.P.; Tapley, B. D.; Stewart, R. H. J. Geophys. Res. 1997, 102C, 10525-10533. 3

  6. Heat training increases exercise capacity in hot but not in temperate conditions: a mechanistic counter-balanced cross-over study.

    Science.gov (United States)

    Keiser, Stefanie; Flück, Daniela; Hüppin, Fabienne; Stravs, Alexander; Hilty, Matthias P; Lundby, Carsten

    2015-09-01

    The aim was to determine the mechanisms facilitating exercise performance in hot conditions following heat training. In a counter-balanced order, seven males (V̇o2max 61.2 ± 4.4 ml·min(-1)·kg(-1)) were assigned to either 10 days of 90-min exercise training in 18 or 38°C ambient temperature (30% relative humidity) applying a cross-over design. Participants were tested for V̇o2max and 30-min time trial performance in 18 (T18) and 38°C (T38) before and after training. Blood volume parameters, sweat output, cardiac output (Q̇), cerebral perfusion (i.e., middle cerebral artery velocity [MCAvmean]), and other variables were determined. Before one set of exercise tests in T38, blood volume was acutely expanded by 538 ± 16 ml with an albumin solution (T38A) to determine the role of acclimatization induced hypervolemia on exercise performance. We furthermore hypothesized that heat training would restore MCAvmean and thereby limit centrally mediated fatigue. V̇o2max and time trial performance were equally reduced in T38 and T38A (7.2 ± 1.6 and 9.3 ± 2.5% for V̇o2max; 12.8 ± 2.8 and 12.9 ± 2.8% for time trial). Following heat training both were increased in T38 (9.6 ± 2.1 and 10.4 ± 3.1%, respectively), whereas both V̇o2max and time trial performance remained unchanged in T18. As expected, heat training augmented plasma volume (6 ± 2%) and mean sweat output (26 ± 6%), whereas sweat [Na(+)] became reduced by 19 ± 7%. In T38 Q̇max remained unchanged before (21.3 ± 0.6 l/min) to after (21.7 ± 0.5 l/min) training, whereas MCAvmean was increased by 13 ± 10%. However, none of the observed adaptations correlated with the concomitant observed changes in exercise performance. Copyright © 2015 the American Physiological Society.

  7. Heat pumps in district heating networks

    DEFF Research Database (Denmark)

    Ommen, Torben Schmidt; Markussen, Wiebke Brix; Elmegaard, Brian

    constraints limit the power plants. Efficient heat pumps can be used to decouple the constraints of electricity and heat production, while maintaining the high energy efficiency needed to match the politically agreed carbon emission goals. The requirements in terms of COP, location, capacity and economy...... are calculated using an energy system model which includes power plants, heat pumps and district heating consumption profiles. The model is developed with focus on accurate representation of the performance of the units in different locations and operating modes. The model can assist in investment decisions...... and strategic planning in the energy sector. The paper presents a case study of optimal implementation of heat pumps in the present energy system of the Copenhagen area. By introduction of the correct capacity of heat pumps, a 1,6 % reduction in fuel consumption for electricity and heat production can...

  8. Non-Debye heat capacity formula refined and applied to GaP, GaAs, GaSb, InP, InAs, and InSb

    Directory of Open Access Journals (Sweden)

    R. Pässler

    2013-08-01

    Full Text Available Characteristic non-Debye behaviors of low-temperature heat capacities of GaP, GaAs, GaSb, InP, InAs, and InSb, which are manifested above all in form of non-monotonic behaviors (local maxima of the respective Cp(T/T3 curves in the cryogenic region, are described by means of a refined version of a recently proposed low-to-high-temperature interpolation formula of non-Debye type. Least-mean-square fittings of representative Cp(T data sets available for these materials from several sources show excellent agreements, from the liquid-helium region up to room temperature. The results of detailed calculations of the respective material-specific Debye temperature curves, ΘD(T, are represented in graphical form. The strong, non-monotonic variations of ΘD(T values confirm that it is impossible to provide reasonable numerical simulations of measured Cp(T dependences in terms of fixed Debye temperatures. We show that it is possible to describe in good approximation the complete Debye temperature curves, from the cryogenic region up to their definitive disappearance (dropping to 0 in the high temperature region, by a couple of unprecedented algebraic formulas. The task of constructing physically adequate prolongations of the low-temperature Cp(T curves up to melting points was strongly impeded by partly rather large differences (up to an order of 10 J/(K·mol between the high-temperature data sets presented in different research papers and/or data reviews. Physically plausible criteria are invoked, which enabled an a priori rejection of a series of obviously unrealistic high-temperature data sets. Residual uncertainties for GaAs and InAs could be overcome by re-evaluations of former enthalpy data on the basis of a novel set of properly specified four-parameter polynomial expressions applying to large regions, from moderately low temperatures up to melting points. Detailed analytical and numerical descriptions are given for the anharmonicity

  9. Phase Diagram of HgTe -ZnTe Pseudobinary and Density, Heat Capacity, and Enthalphy of Mixing of Hg(sub 1-x)Zn(sub x)Te Pseudobinary Melts

    Science.gov (United States)

    Su, Ching-Hua; Sha, Yi-Gao; Mazuruk, K.; Lehoczky, S. L.

    1996-01-01

    In this article, the solidus temperatures of the Hg(sub 1-x) Zn(sub x)Te pseudobinary phase diagram for several compositions in the low x region were measured by differential thermal analysis and the HgTe-ZnTe pseudobinary phase diagram was constructed. The densities of two HgZnTe melts, x = 0.10 and 0.16, were determined by an in situ pycnometric technique in a transparent furnace over, respectively, 110 and 50 C ranges of temperature. The thermodynamic properties of the melts, such as the heat capacity and enthalpy of mixing, were calculated for temperatures between the liquidus and 1500 C by assuming an associated solution model for the liquid phase.

  10. Thermal degradation kinetics of anthocyanins extracted from juçara (Euterpe edulis Martius) and "Italia" grapes (Vitis vinifera L.), and the effect of heating on the antioxidant capacity.

    Science.gov (United States)

    Peron, D V; Fraga, S; Antelo, F

    2017-10-01

    The effect of temperature on the degradation of anthocyanins in juçara and "Italia" grape extracts was determined between 50 and 90°C. For both species, thermal degradation followed a first-order kinetic model. The decimal reduction time decreased with increasing temperature, and dependence on the thermodegradable factor was lower at higher temperatures. The anthocyanins from juçara degraded more slowly than those extracted from "Italia" grapes. The activation enthalpy and free energy of inactivation indicated an endothermic reaction, not spontaneous degradation, whereas the activation entropy suggested that the transition state has less structural freedom than that of the reactants. The antioxidant capacity of the extracts was reduced when subjected to 90°C heat treatment, however, significant quantities of this bioactive compound still remained. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. VTX HyHeat Project

    Data.gov (United States)

    National Aeronautics and Space Administration — In this project Orbital Technologies Corporation (ORBITEC) will utilize its unique vortex propulsion technology to develop a high-capacity heating system to heat...

  12. Carrying Capacity

    DEFF Research Database (Denmark)

    Schroll, Henning; Andersen, Jan; Kjærgård, Bente

    2012-01-01

    A spatial planning act was introduced inIndonesia 1992 and renewed in 2008. It emphasised the planning role of decentralised authorities. The spatial planning act covers both spatial and environmental issues. It defines the concept of carrying capacity and includes definitions of supportive....../cities. Four different sectors (water, food production, waste, and forests) were selected as core areas for decentralised spatial planning. Indicators for SCC and ACC were identified and assessed with regard to relevance and quantifiability. For each of the indicators selected, a legal threshold or guiding...... was introduced inIndonesia 1992 and renewed in 2008. It emphasised the planning role of decentralised authorities. The spatial planning act covers both spatial and environmental issues. It defines the concept of carrying capacity and includes definitions of supportive carrying capacity (SCC) and assimilative...

  13. Solar Heating System with Building-Integrated Heat Storage

    DEFF Research Database (Denmark)

    Heller, Alfred

    1996-01-01

    Traditional solar heating systems cover between 5 and 10% of the heat demand fordomestic hot water and comfort heating. By applying storage capacity this share can beincreased much. The Danish producer of solar heating systems, Aidt-Miljø, markets such a system including storage of dry sand heated...... by PP-pipe heat exchanger. Heat demand is reduced due to direct solar heating, and due to storage. Heat demand is reduced due to direct solar heating, due to storage and due to lower heat losses through the ground. In theory, by running the system flow backwards through the sand storage, active heating...... can be achieved.The objective of the report is to present results from measured system evaluation andcalculations and to give guidelines for the design of such solar heating systems with building integrated sand storage. The report is aimed to non-technicians. In another report R-006 the main results...

  14. The Heat Is on: An Inquiry-Based Investigation for Specific Heat

    Science.gov (United States)

    Herrington, Deborah G.

    2011-01-01

    A substantial number of upper-level science students and practicing physical science teachers demonstrate confusion about thermal equilibrium, heat transfer, heat capacity, and specific heat capacity. The traditional method of instruction, which involves learning the related definitions and equations, using equations to solve heat transfer…

  15. Heat Roadmap Europe

    DEFF Research Database (Denmark)

    David, Andrei; Mathiesen, Brian Vad; Averfalk, Helge

    2017-01-01

    The Heat Roadmap Europe (HRE) studies estimated a potential increase of the district heating (DH) share to 50% of the entire heat demand by 2050, with approximately 25–30% of it being supplied using large-scale electric heat pumps. This study builds on this potential and aims to document...... that such developments can begin now with technologies currently available. We present a database and the status of the technology and its ability of expansion to other European locations by reviewing experiences aimed at further research or application in the heating industry. This is based on a survey of the existing...... capacity of electric large-scale heat pumps with more than 1 MW thermal output, operating in European DH systems. The survey is the first database of its kind containing the technical characteristics of these heat pumps, and provides the basis for the analysis of this paper. By quantifying the heat sources...

  16. Geothermal properties of Swiss Molasse Basin (depth range 0-500 m) - 2006 upgrade of the thermal conductivity, heat capacity, rock density and porosity data base; Geothermische Eigenschaften der Schweizer Molasse (Tiefenbereich 0-500 m). Datenbank fuer Waermeleitfaehigkeit, spezifische Waermekapazitaet, Gesteinsdichte und Porositaet. Ueberarbeitung 2006

    Energy Technology Data Exchange (ETDEWEB)

    Leu, W. [Geoform AG, Minusio (Switzerland); Megel, T. [Geowatt, Zuerich (Switzerland); Schaerli, U. [Geologie und Geophysik, Zuerich (Switzerland)

    2006-07-01

    The main aim of this project is the preparation of a specific data base of geothermal properties for typical rocks of the Swiss Molasse Basin (depth interval 0-500 m). The project includes the development of a new laboratory tool for efficient heat capacity measurements on rock samples, numerous new measurements of geothermal rock properties in the laboratory and calculation of such data from geophysical borehole logs. In the geographical area under review, 282 rock samples, mainly from deep boreholes, were analyzed with the successfully calibrated new heat capacity device and conventional thermal conductivity measuring techniques (cuttings and cores). Based on sonic and density log data from exploration wells, 374 additional data points were generated. This new data base characterizes in detail the six main lithological rock types in the three Molasse groups OSM, OMM and USM within the Swiss Plateau Molasse. The statistical evaluation of all data illustrates the regional variation of the petrophysical and geothermal parameters. For most data groups bulk rock density and thermal conductivity increase, whereas heat capacity decreases in the direction towards the Alpine front. Thermal conductivity shows a distinct increase with depth. Based on this new information and with the aid of the evaluation software tool SwEWS, the costs of planned geothermal installations can be optimized thanks to more precise heat extraction simulations with existing software packages like COSOND, TRNSYS, EWS or WPcalc. (author)

  17. Riemann solvers for multi-component gas mixtures with temperature dependent heat capacities; Solveurs de riemann pour des melanges de gaz parfaits avec capacites calorifiques dependant de la temperature

    Energy Technology Data Exchange (ETDEWEB)

    Beccantini, A

    2001-07-01

    This thesis represents a contribution to the development of upwind splitting schemes for the Euler equations for ideal gaseous mixtures and their investigation in computing multidimensional flows in irregular geometries. In the preliminary part we develop and investigate the parameterization of the shock and rarefaction curves in the phase space. Then, we apply them to perform some field-by-field decompositions of the Riemann problem: the entropy-respecting one, the one which supposes that genuinely-non-linear (GNL) waves are both shocks (shock-shock one) and the one which supposes that GNL waves are both rarefactions (rarefaction-rarefaction one). We emphasize that their analysis is fundamental in Riemann solvers developing: the simpler the field-by-field decomposition, the simpler the Riemann solver based on it. As the specific heat capacities of the gases depend on the temperature, the shock-shock field-by-field decomposition is the easiest to perform. Then, in the second part of the thesis, we develop an upwind splitting scheme based on such decomposition. Afterwards, we investigate its robustness, precision and CPU-time consumption, with respect to some of the most popular upwind splitting schemes for polytropic/non-polytropic ideal gases. 1-D test-cases show that this scheme is both precise (exact capturing of stationary shock and stationary contact) and robust in dealing with strong shock and rarefaction waves. Multidimensional test-cases show that it suffers from some of the typical deficiencies which affect the upwind splitting schemes capable of exact capturing stationary contact discontinuities i.e the developing of non-physical instabilities in computing strong shock waves. In the final part, we use the high-order multidimensional solver here developed to compute fully-developed detonation flows. (author)

  18. LT-IIb(T13I, a non-toxic type II heat-labile enterotoxin, augments the capacity of a ricin toxin subunit vaccine to evoke neutralizing antibodies and protective immunity.

    Directory of Open Access Journals (Sweden)

    Christopher J Greene

    Full Text Available Currently, there is a shortage of adjuvants that can be employed with protein subunit vaccines to enhance protection against biological threats. LT-IIb(T13I is an engineered nontoxic derivative of LT-IIb, a member of the type II subfamily of heat labile enterotoxins expressed by Escherichia coli, that possesses potent mucosal adjuvant properties. In this study we evaluated the capacity of LT-IIb(T13I to augment the potency of RiVax, a recombinant ricin toxin A subunit vaccine, when co-administered to mice via the intradermal (i.d. and intranasal (i.n. routes. We report that co-administration of RiVax with LT-IIb(T13I by the i.d. route enhanced the levels of RiVax-specific serum IgG antibodies (Ab and elevated the ratio of ricin-neutralizing to non-neutralizing Ab, as compared to RiVax alone. Protection against a lethal ricin challenge was also augmented by LT-IIb(T13I. While local inflammatory responses elicited by LT-IIb(T13I were comparable to those elicited by aluminum salts (Imject®, LT-IIb(T13I was more effective than aluminum salts at augmenting production of RiVax-specific serum IgG. Finally, i.n. administration of RiVax with LT-IIb(T13I also increased levels of RiVax-specific serum and mucosal Ab and enhanced protection against ricin challenge. Collectively, these data highlight the potential of LT-IIb(T13I as an effective next-generation i.d., or possibly i.n. adjuvant for enhancing the immunogenicity of subunit vaccines for biodefense.

  19. Hemispherical total emissivity and specific heat capacity of deeply undercooled Zr{sub 41.2}Ti{sub 13.8}Cu{sub 12.5}Ni{sub 10.0}Be{sub 22.5} melts

    Energy Technology Data Exchange (ETDEWEB)

    Busch, R.; Kim, Y.J.; Johnson, W.L. [W. M. Keck Laboratory of Engineering Materials, California Institute of Technology, Pasadena, California 91125 (United States); Rulison, A.J.; Rhim, W.K. [Jet Propulsion Laboratory, California Institute of Technology, Pasadena, California 91109 (United States); Isheim, D. [Institut fuer Metallphysik der Universitaet Goettingen, Hospitalstrasse 3-7, 37073 Goettingen (Germany)

    1995-06-05

    High-temperature high-vacuum electrostatic levitation (HTHVESL) and differential scanning calorimetry (DSC) were combined to determine the hemispherical total emissivity {epsilon}{sub {ital T}}, and the specific heat capacity {ital c}{sub {ital p}}, of the undercooled liquid and throughout the glass transition of the Zr{sub 41.2}Ti{sub 13.8}Cu{sub 12.5}Ni{sub 10.0}Be{sub 22.5} bulk metallic glass forming alloy. The ratio of {ital c}{sub {ital p}}/{epsilon}{sub {ital T}} as a function of undercooling was determining from radiative cooling curves measured in the HTHVESL. Using specific heat capacity data obtained by DSC investigations close to the glass transition and above the melting point, {epsilon}{sub {ital T}} and {ital c}{sub {ital p}} were separated and the specific heat capacity of the whole undercooled liquid region was determined. Furthermore, the hemispherical total emissivity of the liquid was found to be about 0.22 at 980 K. On undercooling the liquid, the emissivity decreases to approximately 0.18 at about 670 K, where the undercooled liquid starts to freeze to a glass. No significant changes of the emissivity are observed as the alloy undergoes the glass transition. {copyright} {ital 1995} {ital American} {ital Institute} {ital of} {ital Physics}.

  20. Heat capacity and neutron diffraction studies on the frustrated magnetic Co{sub 2}(OH)(PO{sub 4}){sub 1-x}(AsO{sub 4}){sub x} [0{<=}x{<=}1] solid solution

    Energy Technology Data Exchange (ETDEWEB)

    Pedro, I. de, E-mail: depedrovm@unican.es [CITIMAC, Facultad de Ciencias, Universidad de Cantabria, 39005 Santander (Spain); Departamento de Quimica Inorganica, Facultad de Ciencia y Tecnologia, Universidad del Pais Vasco, 48080 Bilbao (Spain); Rojo, J.M. [Departamento de Quimica Inorganica, Facultad de Ciencia y Tecnologia, Universidad del Pais Vasco, 48080 Bilbao (Spain); Rodriguez Fernandez, J.; Sanchez Marcos, J. [CITIMAC, Facultad de Ciencias, Universidad de Cantabria, 39005 Santander (Spain); Fernandez-Diaz, M.T. [Institut Laue-Langevin, BP 156X, F-38042 Grenoble Cedex (France); Rojo, T. [Departamento de Quimica Inorganica, Facultad de Ciencia y Tecnologia, Universidad del Pais Vasco, 48080 Bilbao (Spain)

    2012-04-15

    The Co{sub 2}(OH)(PO{sub 4}){sub 1-x}(AsO{sub 4}){sub x} [0{<=}x{<=}1] solid solution exhibits a complex magnetic behaviour due to the bond-frustration in its magnetic structure. Heat capacity measurements of the (x=0.1-0.5) phases show a three-dimensional magnetic ordering ({lambda} anomaly) that shifts to lower temperatures and becomes broader as the AsO{sub 4}{sup 3-} content increases. For x=0.75, no significant feature was observed whereas for higher arsenate ion content, x=0.9 and 1, a small maximum was detected. The magnetic structures of solid solution are consistent with the existence of predominant antiferromagnetic superexchange interactions through the |OH| and |XO{sub 4}| (X=P and As) groups between the Co{sup +2} ions. The substitution of PO{sub 4}{sup 3-} by AsO{sub 4}{sup 3-} anions by more than 90% substantially modifies the magnetic exchange pathways in the solid solution, leading to an incommensurate antiferromagnetic structure in Co{sub 2}(OH)(PO{sub 4}){sub 1-x}(AsO{sub 4}){sub x} [x=0.9 and 1] phases. - Graphical abstract: Magnetic structures of Co{sub 2}(OH)(PO{sub 4}){sub 1-x}(AsO{sub 4}){sub x} [0{<=}x{<=}1]. The ordering of the magnetic moments of Co{sup 2+} is in c direction for the two crystallographic positions (dimers and chains) in all compounds. The unit cell is surrounded by a red line. Highlights: Black-Right-Pointing-Pointer Synthesis of a new adamite-type compounds, Co{sub 2}(OH)(PO{sub 4}){sub 1-x}(AsO{sub 4}){sub x} (0.1, 0.25, 0.5, 0.75, 0.9) phases. Black-Right-Pointing-Pointer Co{sub 2}(OH)(PO{sub 4}){sub 1-x}(AsO{sub 4}){sub x} (0-1) solid solution; magnetic frustrated system. Black-Right-Pointing-Pointer High resolution neutron powder diffraction to determine the crystal structures. Black-Right-Pointing-Pointer Incommensurate magnetic structures at low temperature. Black-Right-Pointing-Pointer Magnetostructural correlations in cobalt-based Co{sub 2}(OH)XO{sub 4} (X=P and As) insulation compounds.

  1. Chemical heat pump

    Science.gov (United States)

    Greiner, Leonard

    1980-01-01

    A chemical heat pump system is disclosed for use in heating and cooling structures such as residences or commercial buildings. The system is particularly adapted to utilizing solar energy, but also increases the efficiency of other forms of thermal energy when solar energy is not available. When solar energy is not available for relatively short periods of time, the heat storage capacity of the chemical heat pump is utilized to heat the structure as during nighttime hours. The design also permits home heating from solar energy when the sun is shining. The entire system may be conveniently rooftop located. In order to facilitate installation on existing structures, the absorber and vaporizer portions of the system may each be designed as flat, thin wall, thin pan vessels which materially increase the surface area available for heat transfer. In addition, this thin, flat configuration of the absorber and its thin walled (and therefore relatively flexible) construction permits substantial expansion and contraction of the absorber material during vaporization and absorption without generating voids which would interfere with heat transfer. The heat pump part of the system heats or cools a house or other structure through a combination of evaporation and absorption or, conversely, condensation and desorption, in a pair of containers. A set of automatic controls change the system for operation during winter and summer months and for daytime and nighttime operation to satisfactorily heat and cool a house during an entire year. The absorber chamber is subjected to solar heating during regeneration cycles and is covered by one or more layers of glass or other transparent material. Daytime home air used for heating the home is passed at appropriate flow rates between the absorber container and the first transparent cover layer in heat transfer relationship in a manner that greatly reduce eddies and resultant heat loss from the absorbant surface to ambient atmosphere.

  2. The decrease in the IgG-binding capacity of intensively dry heated whey proteins is associatead with intense Maillard reaction, structural changes of the proteins and formation of RAGE-ligands

    NARCIS (Netherlands)

    Liu, F.; Teodorowicz, M.; Boekel, van M.A.J.S.; Wichers, H.J.; Hettinga, K.A.

    2016-01-01

    Heat treatment is the most common way of milk processing, inducing structural changes as well as chemical modifications in milk proteins. These modifications influence the immune-reactivity and allergenicity of milk proteins. This study shows the influence of dry heating on the solubility, particle

  3. Heat Islands

    Science.gov (United States)

    EPA's Heat Island Effect Site provides information on heat islands, their impacts, mitigation strategies, related research, a directory of heat island reduction initiatives in U.S. communities, and EPA's Heat Island Reduction Program.

  4. Heat Waves

    Science.gov (United States)

    Heat Waves Dangers we face during periods of very high temperatures include: Heat cramps: These are muscular pains and ... having trouble with the heat. If a heat wave is predicted or happening… - Slow down. Avoid strenuous ...

  5. Building physics: wood fiber plates - insulating materials as a heat storage system; Bauphysik: Holzfaserdaemmplatten - Daemmstoffe als Waermespeicher

    Energy Technology Data Exchange (ETDEWEB)

    Hauser, G.

    2006-12-13

    A high heat storage cabability is very effectful due to summer heat behaviour. Advanced heat insulating materials with high heat capacities and raw densities enable the enhancement of heat storage without losses on thermal protection. (GL)

  6. Optimal usage of low temperature heat sources to supply district heating by heat pumps

    DEFF Research Database (Denmark)

    Pieper, Henrik; Ommen, Torben Schmidt; Markussen, Wiebke Brix

    2017-01-01

    This paper presents a theoretical study on the optimal usage of different low temperature heat sources to supply district heating by heat pumps. The study is based on data for the Copenhagen region. The heat sources were prioritized based on the coefficient of performance calculated for each hour....... Groundwater, seawater and air heat sources were compared with each other as well as to a scenario consisting of a combination of these heat sources. In addition, base load and peak load units were included. Characteristic parameters were the coefficient of performance, the number of full load hours......% groundwater, 22% seawater and 0% air resulted in highest COP of 3.33 for the given heat demand. Furthermore, the implementation of rule based short term storage made peak units redundant. The variation in base load capacity showed that heat pumps utilizing the analyzed heat sources could perform very...

  7. The monogroove high performance heat pipe

    Science.gov (United States)

    Alario, J.; Haslett, R.; Kosson, R.

    1981-06-01

    The development of the monogroove heat pipe, a fundamentally new high-performance device suitable for multi-kilowatt space radiator heat-rejection systems, is reported. The design separates heat transport and transfer functions, so that each can be separately optimized to yield heat transport capacities on the order of 25 kW/m. Test versions of the device have proven the concept of heat transport capacity control by pore dimensions and the permeability of the circumferential wall wick structure, which together render it insensitive to tilt. All cases tested were for localized, top-side heat input and cooling and produced results close to theoretical predictions.

  8. Heat Stress

    Science.gov (United States)

    ... Publications and Products Programs Contact NIOSH NIOSH HEAT STRESS Recommend on Facebook Tweet Share Compartir NEW OSHA- ... hot environments may be at risk of heat stress. Exposure to extreme heat can result in occupational ...

  9. The wood chip fuelled heating system at Wald-Michelbach. A boiler system with a rated thermal capacity of 440 kW; Die Hackgutfeuerungsanlage in Wald-Michelbach. Eine Kesselanlage mit 440 kW Nennwaermeleistung

    Energy Technology Data Exchange (ETDEWEB)

    Schmitt, A. [Adam-Karrillon-Schule, Wald-Michelbach (Germany)

    2000-07-01

    The contribution describes the installation of a wood chip fuelled heating system in a school building with an annual heat demand of 450,000 kWh per annum. The technology, the environmental effects, investment cost and fuel cost are described. [German] Der Artikel beschreibt die Installation einer Hackschnitzelfeuerungsanlage fuer die Beheizung einer Schule. Der Waermebedarf der Schule liegt bei ca. 450.000 kWh/Jahr. Beschrieben werden die eingesetzte Technologie, der Beitrag zur Umwelt und die Investionskosten und Brennstoffkosten. (SR)

  10. Fiscal 1993 investigational report on heat pump heat storage technology; 1993 nendo heat pump chikunetsu gijutsu ni kansuru chosa hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-03-01

    This project is for an investigation into the heat pump (HP) use heat storage technology, with the aim of clarifying the present status of HP heat storage technology, the utilization status, and the developmental trend of technology and of contributing to the spread of heat energy effective use using HP heat storage technology and to the promotion of the technical development. Accordingly, the evaluation of the following was made: sensible heat (SH), latent heat (LH), chemical heat storage technology (CH), and heat storage technology (HS). Investigations were made on the sensible heat use heat storage technology of water, brine, stone, soil, etc. in terms of SH; the phase change sensible heat use heat storage technology of ice, hydrate salt, paraffins, etc. in terms of LH; hydration, hydroxide, 2-propanol pyrolysis, adsorption of silica gel, zeolite and water, and heat storage technology using metal hydride, etc. in terms of CH. In terms of HS, the following were studied and evaluated from the study results of the heat storage system in which HP is applied to the sensible heat and latent heat type heat storage technology: contribution to the power load levelling and the reduction of heat source capacity, heat recovery and the use of unused energy, improvement of the system efficiency by combining HP and heat storage technology. 24 refs., 242 figs., 56 tabs.

  11. Investigation on Solar Heating System with Building-Integrated Heat Storage

    DEFF Research Database (Denmark)

    Heller, Alfred

    1996-01-01

    Traditional solar heating systems cover between 5 and 10% of the heat demand fordomestic hot water and comfort heating. By applying storage capacity this share can beincreased much. The Danish producer of solar heating systems, Aidt-Miljø, markets such a system including storage of dry sand heated...... by PP-pipe heat exchanger. Heat demand is reduced due to direct solar heating and due to storage. The storage affects the heat demand passively due to higher temperatures. Hence heat loss is reduced and passive heating is optioned. In theory, by running the system flow backwards, active heating can...... solar collector area of the system, was achieved. Active heating from the sand storage was not observed. The pay-back time for the system can be estimated to be similar to solar heated domestic hot water systems in general. A number of minor improvements on the system could be pointed out....

  12. 46 CFR 154.178 - Contiguous hull structure: Heating system.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Contiguous hull structure: Heating system. 154.178... Equipment Hull Structure § 154.178 Contiguous hull structure: Heating system. The heating system for... the heating capacity to meet § 154.174(b)(2) or § 154.176(b)(2); (b) Have stand-by heating to provide...

  13. Passive Vaporizing Heat Sink

    Science.gov (United States)

    Knowles, TImothy R.; Ashford, Victor A.; Carpenter, Michael G.; Bier, Thomas M.

    2011-01-01

    A passive vaporizing heat sink has been developed as a relatively lightweight, compact alternative to related prior heat sinks based, variously, on evaporation of sprayed liquids or on sublimation of solids. This heat sink is designed for short-term dissipation of a large amount of heat and was originally intended for use in regulating the temperature of spacecraft equipment during launch or re-entry. It could also be useful in a terrestrial setting in which there is a requirement for a lightweight, compact means of short-term cooling. This heat sink includes a hermetic package closed with a pressure-relief valve and containing an expendable and rechargeable coolant liquid (e.g., water) and a conductive carbon-fiber wick. The vapor of the liquid escapes when the temperature exceeds the boiling point corresponding to the vapor pressure determined by the setting of the pressure-relief valve. The great advantage of this heat sink over a melting-paraffin or similar phase-change heat sink of equal capacity is that by virtue of the =10x greater latent heat of vaporization, a coolant-liquid volume equal to =1/10 of the paraffin volume can suffice.

  14. Heat pumps in combined heat and power systems

    DEFF Research Database (Denmark)

    Ommen, Torben Schmidt; Markussen, Wiebke Brix; Elmegaard, Brian

    2014-01-01

    Heat pumps have previously been proposed as a way to integrate higher amounts of renewable energy in DH (district heating) networks by integrating, e.g., wind power. The paper identifies and compares five generic configurations of heat pumps in DH systems. The operational performance...... of the considered cases. When considering a case where the heat pump is located at a CHP (combined heat and power) plant, a configuration that increases the DH return temperature proposes the lowest operation cost, as low as 12 EUR MWh-1 for a 90 °C e 40 °C DH network. Considering the volumetric heating capacity......, a third configuration is superior in all cases. Finally, the three most promising heat pump configurations are integrated in a modified PQ-diagram of the CHP plant. Each show individual advantages, and for two, also disadvantages in order to achieve flexible operation....

  15. Solar-powered Rankine heat pump for heating and cooling

    Science.gov (United States)

    Rousseau, J.

    1978-01-01

    The design, operation and performance of a familyy of solar heating and cooling systems are discussed. The systems feature a reversible heat pump operating with R-11 as the working fluid and using a motor-driven centrifugal compressor. In the cooling mode, solar energy provides the heat source for a Rankine power loop. The system is operational with heat source temperatures ranging from 155 to 220 F; the estimated coefficient of performance is 0.7. In the heating mode, the vapor-cycle heat pump processes solar energy collected at low temperatures (40 to 80 F). The speed of the compressor can be adjusted so that the heat pump capacity matches the load, allowing a seasonal coefficient of performance of about 8 to be attained.

  16. Heat pumps

    CERN Document Server

    Macmichael, DBA

    1988-01-01

    A fully revised and extended account of the design, manufacture and use of heat pumps in both industrial and domestic applications. Topics covered include a detailed description of the various heat pump cycles, the components of a heat pump system - drive, compressor, heat exchangers etc., and the more practical considerations to be taken into account in their selection.

  17. Inverse problem and variation method to optimize cascade heat exchange network in central heating system

    Science.gov (United States)

    Zhang, Yin; Wei, Zhiyuan; Zhang, Yinping; Wang, Xin

    2017-12-01

    Urban heating in northern China accounts for 40% of total building energy usage. In central heating systems, heat is often transferred from heat source to users by the heat network where several heat exchangers are installed at heat source, substations and terminals respectively. For given overall heating capacity and heat source temperature, increasing the terminal fluid temperature is an effective way to improve the thermal performance of such cascade heat exchange network for energy saving. In this paper, the mathematical optimization model of the cascade heat exchange network with three-stage heat exchangers in series is established. Aim at maximizing the cold fluid temperature for given hot fluid temperature and overall heating capacity, the optimal heat exchange area distribution and the medium fluids' flow rates are determined through inverse problem and variation method. The preliminary results show that the heat exchange areas should be distributed equally for each heat exchanger. It also indicates that in order to improve the thermal performance of the whole system, more heat exchange areas should be allocated to the heat exchanger where flow rate difference between two fluids is relatively small. This work is important for guiding the optimization design of practical cascade heating systems.

  18. Customer Driven Capacity Setting

    OpenAIRE

    Hübl, Alexander; Altendorfer, Klaus; Jodlbauer, Herbert; Pilstl, Josef

    2010-01-01

    International audience; The purpose of this article is to develop a method for short and medium term capacity setting decisions for providing a market oriented level of available capacity for the investigated machine groups. An MTO (make to order) production system is considered. The basic concept is that the cumulative available capacity of the machine group has to be greater than or equal to the cumulative needed capacity influenced by the customer orders. The cumulative needed capacity is ...

  19. High capacity carbon dioxide sorbent

    Energy Technology Data Exchange (ETDEWEB)

    Dietz, Steven Dean; Alptekin, Gokhan; Jayaraman, Ambalavanan

    2015-09-01

    The present invention provides a sorbent for the removal of carbon dioxide from gas streams, comprising: a CO.sub.2 capacity of at least 9 weight percent when measured at 22.degree. C. and 1 atmosphere; an H.sub.2O capacity of at most 15 weight percent when measured at 25.degree. C. and 1 atmosphere; and an isosteric heat of adsorption of from 5 to 8.5 kilocalories per mole of CO.sub.2. The invention also provides a carbon sorbent in a powder, a granular or a pellet form for the removal of carbon dioxide from gas streams, comprising: a carbon content of at least 90 weight percent; a nitrogen content of at least 1 weight percent; an oxygen content of at most 3 weight percent; a BET surface area from 50 to 2600 m.sup.2/g; and a DFT micropore volume from 0.04 to 0.8 cc/g.

  20. Heat pumps

    CERN Document Server

    Brodowicz, Kazimierz; Wyszynski, M L; Wyszynski

    2013-01-01

    Heat pumps and related technology are in widespread use in industrial processes and installations. This book presents a unified, comprehensive and systematic treatment of the design and operation of both compression and sorption heat pumps. Heat pump thermodynamics, the choice of working fluid and the characteristics of low temperature heat sources and their application to heat pumps are covered in detail.Economic aspects are discussed and the extensive use of the exergy concept in evaluating performance of heat pumps is a unique feature of the book. The thermodynamic and chemical properties o

  1. Total iron binding capacity

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003489.htm Total iron binding capacity To use the sharing features on this page, please enable JavaScript. Total iron binding capacity (TIBC) is a blood test to ...

  2. Responsibility and Capacities

    DEFF Research Database (Denmark)

    Ryberg, Jesper

    2014-01-01

    That responsible moral agency presupposes certain mental capacities, constitutes a widely accepted view among theorists. Moreover, it is often assumed that degrees in the development of the relevant capacities co-vary with degrees of responsibility. In this article it is argued that, the move from...... the view that responsibility requires certain mental capacities to the position that degrees of responsibility co-vary with degrees of the development of the mental capacities, is premature....

  3. CDMA systems capacity engineering

    CERN Document Server

    Kim, Kiseon

    2004-01-01

    This new hands-on resource tackles capacity planning and engineering issues that are crucial to optimizing wireless communication systems performance. Going beyond the system physical level and investigating CDMA system capacity at the service level, this volume is the single-source for engineering and analyzing systems capacity and resources.

  4. HEAT RECUPERATION

    Directory of Open Access Journals (Sweden)

    S. L. Rovin

    2011-01-01

    Full Text Available Heat recovery is an effective method of shortening specific energy consumption. new constructions of recuperators for heating and cupola furnaces have been designed and successfully introduced. two-stage recuperator with computer control providing blast heating up to 600 °C and reducing fuel consumption by 30% is of special interest.

  5. Heated Goggles

    Science.gov (United States)

    1978-01-01

    The electrically heated ski goggles shown incorporate technology similar to that once used in Apollo astronauts' helmet visors, and for the same reason-providing fogfree sight in an activity that demands total vision. Defogging is accomplished by applying heat to prevent moisture condensation. Electric heat is supplied by a small battery built into the h goggles' headband. Heat is spread across the lenses by means of an invisible coating of electrically conductive metallic film. The goggles were introduced to the market last fall. They were designed by Sierracin Corporation, Sylmar, California, specialists in the field of heated transparent materials. The company produces heated windshields for military planes and for such civil aircraft as the Boeing 747, McDonnell Douglas DC-10 and Lockheed L-1011 TriStar.

  6. Capacity Statement for Railways

    DEFF Research Database (Denmark)

    Landex, Alex

    2007-01-01

    The subject “Railway capacity” is a combination of the capacity consumption and how the capacity is utilized. The capacity utilization of railways can be divided into 4 core elements: The number of trains; the average speed; the heterogeneity of the operation; and the stability. This article...... trains. This is due to network effects in the railway system and due to the fact that more trains results in lower punctuality....

  7. Visual attention capacity

    DEFF Research Database (Denmark)

    Habekost, Thomas; Starrfelt, Randi

    2009-01-01

    Psychophysical studies have identified two distinct limitations of visual attention capacity: processing speed and apprehension span. Using a simple test, these cognitive factors can be analyzed by Bundesen's Theory of Visual Attention (TVA). The method has strong specificity and sensitivity...... to patient testing, and review existing TVA-based patient studies organized by lesion anatomy. Lesions in three anatomical regions affect visual capacity: The parietal lobes, frontal cortex and basal ganglia, and extrastriate cortex. Visual capacity thus depends on large, bilaterally distributed anatomical...... networks that include several regions outside the visual system. The two visual capacity parameters are functionally separable, but seem to rely on largely overlapping brain areas....

  8. Residential CO{sub 2} heat pump system for combined space heating and hot water heating

    Energy Technology Data Exchange (ETDEWEB)

    Stene, Joern

    2004-02-01

    Carbon dioxide (CO{sub 2}, R-744) has been identified as a promising alternative to conventional working fluids in a number of applications due to its favourable environmental and thermophysical properties. Previous work on residential CO{sub 2} heat pumps has been dealing with systems for either space heating or hot water heating, and it was therefore considered interesting to carry out a theoretical and experimental study of residential CO{sub 2} heat pump systems for combined space heating and hot water heating - o-called integrated CO{sub 2} heat pump systems. The scope of this thesis is limited to brine-to-water and water-to-water heat pumps connected to low-temperature hydronic space heating systems. The main conclusions are: (1) Under certain conditions residential CO{sub 2} heat pump systems for combined space heating and hot water heating may achieve the same or higher seasonal performance factor (SPF) than the most energy efficient state-of-the-art brine-to-water heat pumps. (2) In contrary to conventional heat pump systems for combined space heating and DHW heating, the integrated CO{sub 2} heat pump system achieves the highest COP in the combined heating mode and the DHW heating mode, and the lowest COP in the space heating mode. Hence, the larger the annual DHW heating demand, the higher the SPF of the integrated CO{sub 2} heat pump system. (3) The lower the return temperature in the space heating system and the lower the DHW storage temperature, the higher the COP of the integrated CO{sub 2} heat pump. A low return temperature in the space heating system also results in a moderate DHW heating capacity ratio, which means that a relatively large part of the annual space heating demand can be covered by operation in the combined heating mode, where the COP is considerably higher than in the space heating mode. (4) During operation in the combined heating mode and the DHW heating mode, the COP of the integrated CO{sub 2} heat pump is heavily influenced by

  9. Heat Sponge: A Concept for Mass-Efficient Heat Storage

    Science.gov (United States)

    Splinter, Scott C.; Blosser, Max L.; Gifford, Andrew R.

    2008-01-01

    The heat sponge is a device for mass-efficient storage of heat. It was developed to be incorporated in the substructure of a re-entry vehicle to reduce thermal- protection-system requirements. The heat sponge consists of a liquid/vapor mixture contained within a number of miniature pressure vessels that can be embedded within a variety of different types of structures. As temperature is increased, pressure in the miniature pressure vessels also increases so that heat absorbed through vaporization of the liquid is spread over a relatively large temperature range. Using water as a working fluid, the heat-storage capacity of the liquid/vapor mixture is many times higher than that of typical structural materials and is well above that of common phase change materials over a temperature range of 200 F to 700 F. The use of pure ammonia as the working fluid provides a range of application between 432 deg R and 730 deg R, or the use of the more practical water-ammonia solution provides a range of application between 432 deg R and 1160 deg R or in between that of water and pure ammonia. Prototype heat sponges were fabricated and characterized. These heat sponges consisted of 1.0-inch-diameter, hollow, stainless-steel spheres with a wall thickness of 0.020 inches which had varying percentages of their interior volumes filled with water and a water-ammonia solution. An apparatus to measure the heat stored in these prototype heat sponges was designed, fabricated, and verified. The heat-storage capacity calculated from measured temperature histories is compared to numerical predictions.

  10. Evaluation of railway capacity

    DEFF Research Database (Denmark)

    Landex, Alex; Kaas, Anders H.; Schittenhelm, Bernd

    2006-01-01

    This paper describes the relatively new UIC 406 method for calculating capacity consumption on railway lines. The UIC 406 method is an easy and effective way of calculating the capacity consumption, but it is possible to expound the UIC 406 method in different ways which can lead to different cap...

  11. Value for railway capacity

    DEFF Research Database (Denmark)

    Sameni, Melody Khadem; Preston, John M.

    2012-01-01

    Growth in rail traffic has not been matched by increases in railway infrastructure. Given this capacity challenge and the current restrictions on public spending, the allocation and the utilization of existing railway capacity are more important than ever. Great Britain has had the greatest growth...... in rail passenger kilometers of European countries since 1996. However, costs are higher and efficiency is lower than European best practice. This paper provides an innovative methodology for assessing the efficiency of passenger operators in capacity utilization. Data envelopment analysis (DEA) is used...... to analyze the efficiency of operators in transforming inputs of allocated capacity of infrastructure and franchise payments into valuable passenger service outputs while avoiding delays. By addressing operational and economic aspects of capacity utilization simultaneously, the paper deviates from existing...

  12. Heat Stroke

    DEFF Research Database (Denmark)

    Mørch, Sofie Søndergaard; Andersen, Johnny Dohn Holmgren; Bestle, Morten Heiberg

    2017-01-01

    Heat stroke is an acute, life-threatening emergency characterized clinically by elevated body temperature and central nervous system dysfunction. Early recognition and treatment including aggressive cooling and management of life-threatening systemic complications are essential to reduce morbidity...... and mortality. This case report describes two Danish patients diagnosed with heat stroke syndrome during a heat wave in the summer of 2014. Both patients were morbidly obese and had several predisposing illnesses. However since heat stroke is a rare condition in areas with temperate climate, they were...... not diagnosed until several days after admittance; hence treatment with cooling was delayed. Both patients were admitted to the intensive care unit, where they were treated with an external cooling device and received treatment for complications. Both cases ended fatally. As global warming continues, more heat...

  13. A method of determining the thermal power demand of buildings connected to the district heating system with usage of heat accumulation

    Science.gov (United States)

    Turski, Michał; Sekret, Robert

    2017-11-01

    The paper presents a new method of determining the thermal power demand of buildings connected to the district heating system, which included the actual heat demand and the possibility of balancing the thermal power using the thermal storage capacity of district heating network and internal heat capacity of buildings. Moreover, the analysis of the effect of incidence of external air temperature and duration of episodes with the lowest outdoor temperatures on the thermal power demand of district heating system was conducted.

  14. Domestic Heat Demand Prediction using Neural Networks

    NARCIS (Netherlands)

    Bakker, Vincent; Molderink, Albert; Hurink, Johann L.; Smit, Gerardus Johannes Maria

    2008-01-01

    By combining a cluster of microCHP appliances, a virtual power plant can be formed. To use such a virtual power plant, a good heat demand prediction of individual households is needed since the heat demand determines the production capacity. In this paper we present the results of using neural

  15. Heat stress management in hot mines

    CSIR Research Space (South Africa)

    Schutte, P

    2009-09-01

    Full Text Available Occupational heat stress is a recognized health and safety hazard in South African mines. The consequences of high occupational heat loads can be expressed in terms of impaired work capacity, errors of judgment with obvious implications for safety...

  16. Performance testing of a hydrogen heat pipe

    Science.gov (United States)

    Alario, J.; Kosson, R.

    1980-01-01

    Test results are presented for a reentrant groove heat pipe with hydrogen working fluid. The heat pipe became operational between 20 and 30 K after a cooldown from 77 K without any difficulty. Steady-state performance data taken over a 19 to 23 K temperature range indicated the following: (1) maximum heat transport capacity = 5.4 W-m; (2) static wicking height = 1.42 cm; and (3) overall heat pipe conductance = 1.7 W/C. These data agreed remarkably well with extrapolations made from comparable ammonia test results. The maximum heat transport capacity is 9.5% larger than the extrapolated value, but the static wicking height is the same. The overall conductance is 29% of the ammonia value, which is close to the ratio of liquid thermal conductivities (24%). Also, recovery from a completely frozen condition was accomplished within 5 min by simply applying an evaporater heat load of 1.8 W.

  17. EFFECTIVE SOLUTIONS FOR THERMOELECTRIC HEAT TRANSFORMERS USING HEAT CONVERTERS

    Directory of Open Access Journals (Sweden)

    A. S. Marchenko

    2016-01-01

    Full Text Available Objectives. The present article is based on the examination of the causes of thermodynamic heat loss in thermoelectric heat transformers. It is shown that the external loss in a real system is comparable to the internal loss in thermoelements at the present stage of thermoelectric engineering instrument development. External technical losses are attributed to the irreversibility of processes in system elements. These are determined by their technical resolution and can be lowered by means of specific approaches to design and construction. Methods. Examples of effective technical solutions for thermoelectric units of the "air-to-air" and "air-to-liquid" types, in which external losses are minimised due to the application of heat exchangers based on two-phase thermosyphons of special configuration, are given. For air coolers with a classic all-metal fin design based on the sensitivity analysis method, the dependence of the thermoelectric unit efficiency on the heat exchanger characteristics was calculated. Results. As a result, calculations of the dependence of cooling unit refrigeration capacity on the energy transformation ratio, power transfer coefficient, energy conversion efficiency (ECE and the relative energetic efficiency of ECE were performed based on the characteristic of the heat exchanger air passage geometry. There is a dependence relationship between the thermoelectric conversion cooling unit refrigeration capacity and transformation ratio within the function of material and thickness of the ribs on the intercostal distance and on the height of the air heat exchanger channel. Conclusion. Examples of the proposed effective thermal circuit technical solutions are based on thermoelectricheat transformers with heat flow direction change and with heat exchangers, which are based on two-phase thermosyphons. Classical solutions of all-metal heat exchangers can also be optimised on the basis of the sensitivity analysis methodology. 

  18. Heat pipes

    CERN Document Server

    Dunn, Peter D

    1994-01-01

    It is approximately 10 years since the Third Edition of Heat Pipes was published and the text is now established as the standard work on the subject. This new edition has been extensively updated, with revisions to most chapters. The introduction of new working fluids and extended life test data have been taken into account in chapter 3. A number of new types of heat pipes have become popular, and others have proved less effective. This is reflected in the contents of chapter 5. Heat pipes are employed in a wide range of applications, including electronics cooling, diecasting and injection mo

  19. Measured Performance of a Low Temperature Air Source Heat Pump

    Energy Technology Data Exchange (ETDEWEB)

    R.K. Johnson

    2013-09-01

    A 4-ton Low Temperature Heat Pump (LTHP) manufactured by Hallowell International was installed in a residence near New Haven, Connecticut and monitored over two winters of operation. After attending to some significant service issues, the heat pump operated as designed. This report should be considered a review of the dual compressor “boosted heat pump” technology. The Low Temperature Heat Pump system operates with four increasing levels of capacity (heat output) as the outdoor temperature drops.

  20. Efecto del ácido indolbutírico, del tipo de la cama de arraigamiento, del substrato, y del árbol madre en la capacidad de arraigamiento de estacas de Nothofagus glauca (Phil. Krasser Effect of indolebutyric acid, bottom heat, substrate, and parent tree on rooting capacity of Nothofagus glauca (Phil. Krasser stem cuttings

    Directory of Open Access Journals (Sweden)

    RÓMULO SANTELICES

    2006-03-01

    , the rooting capacity of stem cuttings was investigated. Using vegetative material collected in November 1995 and 1997, the effect of indolebutyric acid (IBA = 0, 0.5, 1, and 2 %, bed rooting system (bottom heating and without temperature control, substrate (sawdust and bark compost of Pinus radiata D. Don, and parent tree on rhizogenesis was analyzed. Experiments were conducted for 2.5-4 months in a greenhouse. The greenhouse was equipped with an automatic misting system and bottom heating that maintained a temperature of 21-25 °C at the stem base. Results indicate that N. glauca can be propagated from stem cuttings collected from root sprouts in November. Rooting capacity increased with IBA concentrations up to 1 % (88 % of the stem cuttings presented rooting, and decreased at a concentration of 2 %. The presence of leaves was fundamental for the survival and rhizogenesis _ only those stem cuttings with leaves managed to survive and induce root formation. No effect of basal temperature was noted on the rooting capacity consequently, temperature controlled rooting beds are not necessary. Sawdust produced more roots and was the most effective substrate. A marked influence of the parent tree on rooting capacity was observed as well in terms of the percentage of cuttings with roots (6.7-80 % rooting as in length and quantity of the developed roots

  1. Theory of heat

    CERN Document Server

    Maxwell, James Clerk

    2001-01-01

    Though James Clerk Maxwell (1831-1879) is best remembered for his epochal achievements in electricity and magnetism, he was wide-ranging in his scientific investigations, and he came to brilliant conclusions in virtually all of them. As James R. Newman put it, Maxwell ""combined a profound physical intuition, an exquisite feeling for the relationship of objects, with a formidable mathematical capacity to establish orderly connections among diverse phenomena. This blending of the concrete and the abstract was the chief characteristic of almost all his researches.""Maxwell's work on heat and st

  2. Building capacity in Benin

    International Development Research Centre (IDRC) Digital Library (Canada)

    sigp1. Building capacity in. Benin. Training of technical staff of municipalities in the Okpara Basin of Benin in the use of GIS tools for water management, hydrological modeling and soil conservation. Introduction. A training workshop was ...

  3. Temperatures and Heat Flows in a Soil Enclosing a Slinky Horizontal Heat Exchanger

    Directory of Open Access Journals (Sweden)

    Pavel Neuberger

    2014-02-01

    Full Text Available Temperature changes and heat flows in soils that host “slinky”-type horizontal heat exchangers are complex, but need to be understood if robust quantification of the thermal energy available to a ground-source heat pump is to be achieved. Of particular interest is the capacity of the thermal energy content of the soil to regenerate when the heat exchangers are not operating. Analysis of specific heat flows and the specific thermal energy regime within the soil, including that captured by the heat-exchangers, has been characterised by meticulous measurements. These reveal that high concentrations of antifreeze mix in the heat-transfer fluid of the heat exchanger have an adverse impact on heat flows discharged into the soil.

  4. Thermal behavior of a heat exchanger module for seasonal heat storage

    DEFF Research Database (Denmark)

    Fan, Jianhua; Furbo, Simon; Andersen, Elsa

    2012-01-01

    are theoretically investigated by Computational Fluid Dynamics (CFD) calculations. The heat transfer rates between the PCM storage and the heating fluid/cooling fluid in the plate heat exchangers are determined. The CFD calculated temperatures are compared to measured temperatures. Based on the studies......Experimental and theoretic investigations are carried out to study the heat transfer capacity rate of a heat exchanger module for seasonal heat storage with sodium acetate trihydrate (SAT) supercooling in a stable way. A sandwich heat storage test module has been built with the phase change...... material (PCM) storage box in between two plate heat exchangers. Charge of the PCM storage is investigated experimentally with solid phase SAT as initial condition. Discharge of the PCM storage with the presence of crystallization is studied experimentally. Fluid flow and heat transfer in the PCM module...

  5. Aquecimento de vinho tinto e suco de uva utilizados em preparações culinárias não afeta a capacidade antioxidante e o teor de fenóis totais Heating of red wine and grape juice in food preparations does not affect their antioxidant capacity and total phenol content

    Directory of Open Access Journals (Sweden)

    Jeanine Schütz Cardoso Teófilo

    2011-02-01

    Full Text Available OBJETIVO: Avaliar a capacidade antioxidante e a concentração dos compostos fenólicos de vinho tinto e suco de uva utilizados em preparações culinárias, quando submetidos ao processo de fervura. Métodos: A avaliação ocorreu após diferentes períodos de aquecimento (100°C em dois sistemas: i panela de alumínio e chama de fogão e ii balão de vidro e manta térmica. Amostras comerciais de vinho tinto (n=4 e suco de uva integral (n=4 foram submetidas à fervura por 10, 20 e 60 minutos. Antes e após cada período de fervura, a capacidade antioxidante total foi avaliada pela medida do potencial redutor férrico, e o teor de fenóis totais foi quantificado pelo método de Folin-Ciocalteau. As diferenças foram comparadas pela análise de variância para medidas repetidas (pObjective: This study evaluated the antioxidant capacity and concentration of phenolic compounds in red wine and grape juice used in culinary preparations subjected to boiling. Methods: The assessments were done after different boiling times (100°C using two systems: i aluminum pot and stove flame and ii volumetric flask and heating mantle. Samples of red wine (n=4 and grape juice (n=4 were subjected to boiling for 10, 20 and 60 minutes. Before and after each boiling period, the total antioxidant capacity was evaluated by the ferric reducing antioxidant power assay and the total phenol content was determined by the Folin-Ciocalteu reagent. Differences were compared by repeated measures analysis of variance (RM-ANOVA (p<0.05. Results: The different boiling times did not cause significant changes in the total antioxidant capacity or total phenol content of the beverages, regardless of boiling method. Conclusion: The results show that the antioxidant properties of red wine and grape juice did not change significantly after boiling for 60 minutes.

  6. Modular Heat Exchanger With Integral Heat Pipe

    Science.gov (United States)

    Schreiber, Jeffrey G.

    1992-01-01

    Modular heat exchanger with integral heat pipe transports heat from source to Stirling engine. Alternative to heat exchangers depending on integrities of thousands of brazed joints, contains only 40 brazed tubes.

  7. Thermodynamics of the first and second proton dissociations from aqueous L-aspartic acid and L-glutamic acid at temperatures from (278.15 to 393.15) K and at the pressure 0.35 MPa: Apparent molar heat capacities and apparent molar volumes of zwitterionic, protonated cationic, and deprotonated anionic forms at molalities from (0.002 to 1.0) mol . kg{sup -1}

    Energy Technology Data Exchange (ETDEWEB)

    Ziemer, S.P. [Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT 84602-5700 (United States); Woolley, E.M. [Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT 84602-5700 (United States)]. E-mail: earl_woolley@byu.edu

    2007-04-15

    We have measured the densities of aqueous solutions of L-aspartic acid, L-glutamic acid, and equimolal solutions of these two amino acids with HCl and with NaOH at temperatures 278.15 {<=} T/K {<=} 368.15, at molalities 0.002 {<=} m/mol . kg{sup -1} {<=} 1.0 as solubity of the solutes allowed, and at p = 0.35 MPa using a vibrating tube densimeter. We have also measured the heat capacities of these solutions at 278.15 {<=} T/K {<=} 393.15 and at the same m and p using a twin fixed-cell differential temperature-scanning calorimeter. We used the densities to calculate apparent molar volumes V {sub {phi}} and the heat capacities to calculate apparent molar heat capacities C {sub p,{phi}} for these solutions. We used our results and values from the literature for V {sub {phi}}(T, m) and C {sub p,{phi}}(T, m) for HCl(aq), NaOH(aq), and NaCl(aq) and the molar heat capacity change {delta}{sub r} C {sub p,m}(T, m) for ionization of water to calculate parameters for {delta}{sub r} C {sub p,m}(T, m) for the first two proton dissociations from each of the protonated aqueous cationic amino acids. We used Young's Rule and integrated these results iteratively to account for the effects of equilibrium speciation and chemical relaxation on V {sub {phi}}(T, m) and C {sub p,{phi}}(T, m). This procedure gave parameters for V {sub {phi}}(T, m) and C {sub p,{phi}}(T, m) for L-aspartinium and L-glutaminium chlorides and for monosodium L-aspartate and L-glutamate which modeled our observed results within experimental uncertainties. We report values for {delta}{sub r} C {sub p,m}, {delta}{sub r} H {sub m}, pQ {sub a}, {delta}{sub r} S {sub m}, and {delta}{sub r} V {sub m} for the first and second proton dissociations from protonated aqueous L-aspartic acid and L-glutamic acid as functions of T and m.

  8. Apparent molar volumes and apparent molar heat capacities of aqueous N-acetyl-D-glucosamine at temperatures from 278.15 K to 368.15 K and of aqueous N-methylacetamide at temperatures from 278.15 K to 393.15 K at the pressure 0.35 MPa

    Energy Technology Data Exchange (ETDEWEB)

    Swenson, D.M. [Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT 84602-5700 (United States); Ziemer, S.P. [Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT 84602-5700 (United States); Blodgett, M.B. [Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT 84602-5700 (United States); Jones, J.S. [Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT 84602-5700 (United States); Woolley, E.M. [Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT 84602-5700 (United States)]. E-mail: earl_woolley@byu.edu

    2006-12-15

    We determined apparent molar volumes V {sub {phi}} from densities measured with a vibrating-tube densimeter at 278.15 {<=} (T/K) {<=} 368.15 and apparent molar heat capacities C {sub p,{phi}} with a twin fixed-cell, differential, temperature-scanning calorimeter at 278.15 {<=} (T/K) {<=} 363.15 for aqueous solutions of N-acetyl-D-glucosamine at m from (0.01 to 1.0) mol . kg{sup -1} and at p = 0.35 MPa. We also determined V {sub {phi}} at 278.15 {<=} (T/K) {<=} 368.15 and C {sub p,{phi}} at 278.15 {<=} (T/K) {<=} 393.15 for aqueous solutions of N-methylacetamide at m from (0.015 to 1.0) mol . kg{sup -1} and at p = 0.35 MPa. Empirical functions of m and T for each compound were fitted to our results, which are then compared to those for N,N-dimethylacetamide. Estimated values of {delta}{sub r} V {sub m}(m, T) and {delta}{sub r} C {sub p,m}(m, T) for formation of aqueous N-acetyl-D-glucosamine from aqueous D-glucose and aqueous acetamide are calculated and discussed.

  9. Efficacy of heat treatment for disinfestation of concrete grain silos

    Science.gov (United States)

    Field experiments were conducted in 2007 and 2008 to evaluate heat treatment for disinfestations of empty concrete elevator silos. A Mobile Heat Treatment Unit was used to introduce heat into silos to attain target conditions of 50°C for at least 6 h. Ventilated plastic containers with a capacity of...

  10. Loop heat pipes - highly efficient heat-transfer devices for systems of sun heat supply

    Energy Technology Data Exchange (ETDEWEB)

    Maydanik, Yu. [Ural Branch of the Russian Academy of Sciences, Ekaterinburg (Russian Federation). Inst. of Thermophysics

    2004-07-01

    Loop heat pipes (LHPs) are hermetic heat-transfer devices operating on a closed evaporation-condensation cycle with the use of capillary pressure for pumping the working fluid [1]. In accordance with this, they possess all the main advantages of conventional heat pipes, but, as distinct from the latter, have a considerably higher heat-transfer capacity, especially when operating in the ''antigravity'' regime, when heat is transferred from above downwards. Besides, LHPs possess a higher functional versatility, are adaptable to different operating conditions and provide great scope for various design embodiments. This is achieved at the expense of both the original design of the device and the properties of the wick - a special capillary structure used for the creation of capillary pressure. The LHP schematic diagram is given in Fig. 1. The device contains an evaporator and a condenser - heat exchanger connected by means of smooth-walled pipe-lines with a relatively small diameter intended for separate motion of vapor and liquid. At present loop heat pipes are most extensively employed in thermoregulation systems of spacecrafts. Miniature LHPs are used for cooling electronics and computers. At the same time there exists a considerable potential of using these devices for the recovery of low-grade (waste) heat from different sources, and also in systems of sun heat supply. In the latter case LHPs may serve as an efficient heat-transfer link between a sun collector and a heat accumulator, which has a low thermal resistance and does not consume any additional energy for pumping the working fluid between them. (orig.)

  11. On the reliability of negative heat capacity measurements

    Science.gov (United States)

    D'Agostino, M.; Bougault, R.; Gulminelli, F.; Bruno, M.; Cannata, F.; Chomaz, Ph.; Gramegna, F.; Iori, I.; Le Neindre, N.; Margagliotti, G. V.; Moroni, A.; Vannini, G.

    2002-03-01

    A global protocol for the thermostatistical analysis of hot nuclear sources is discussed. Within our method of minimization of variances we show that the abnormal kinetic energy fluctuation signal recently reported in different experimental data from the MULTICS and INDRA collaborations is a genuine signal of a first-order phase transition in a finite system.

  12. Circular Dichroism Method for Heat Capacity Determination of Proteins

    Science.gov (United States)

    Jones, Cecil L.; Bailey, Chris; Bheemarti, Kiran Kumar

    2006-01-01

    Circular dichroism spectroscopy was used to measure the thermal unfolding of bovine pancreatic ribonuclease A (RNase A) with various concentrations of guanidine hydrochloride (GuHCl). A red shift in transition midpoint temperatures, T[subscript m], occurred with increasing concentration of the strong protein denaturant. van Hoff enthalpy changes,…

  13. Anomalous low-temperature heat capacity in antiperovskite compounds

    Science.gov (United States)

    Guo, Xin-Ge; Lin, Jian-Chao; Tong, Peng; Lin, Shuai; Yang, Cheng; Lu, Wen-Jian; Song, Wen-Hai; Sun, Yu-Ping

    2017-02-01

    Not Available Project supported by the National Key Basic Research Program of China (Grant Nos. 2011CBA00111) and the National Natural Science Foundation of China (Grant Nos. 51322105, U1632158, 51301165, and 51301167).

  14. Geothermal Plant Capacity Factors

    Energy Technology Data Exchange (ETDEWEB)

    Greg Mines; Jay Nathwani; Christopher Richard; Hillary Hanson; Rachel Wood

    2015-01-01

    The capacity factors recently provided by the Energy Information Administration (EIA) indicated this plant performance metric had declined for geothermal power plants since 2008. Though capacity factor is a term commonly used by geothermal stakeholders to express the ability of a plant to produce power, it is a term frequently misunderstood and in some instances incorrectly used. In this paper we discuss how this capacity factor is defined and utilized by the EIA, including discussion on the information that the EIA requests from operations in their 923 and 860 forms that are submitted both monthly and annually by geothermal operators. A discussion is also provided regarding the entities utilizing the information in the EIA reports, and how those entities can misinterpret the data being supplied by the operators. The intent of the paper is to inform the facility operators as the importance of the accuracy of the data that they provide, and the implications of not providing the correct information.

  15. Capacity Maximizing Constellations

    Science.gov (United States)

    Barsoum, Maged; Jones, Christopher

    2010-01-01

    Some non-traditional signal constellations have been proposed for transmission of data over the Additive White Gaussian Noise (AWGN) channel using such channel-capacity-approaching codes as low-density parity-check (LDPC) or turbo codes. Computational simulations have shown performance gains of more than 1 dB over traditional constellations. These gains could be translated to bandwidth- efficient communications, variously, over longer distances, using less power, or using smaller antennas. The proposed constellations have been used in a bit-interleaved coded modulation system employing state-ofthe-art LDPC codes. In computational simulations, these constellations were shown to afford performance gains over traditional constellations as predicted by the gap between the parallel decoding capacity of the constellations and the Gaussian capacity

  16. Capacity at Railway Stations

    DEFF Research Database (Denmark)

    Landex, Alex

    2011-01-01

    special focus when conducting UIC 406 capacity analyses.This paper describes how the UIC 406 capacity method can be expounded for stations. Commonly for the analyses of the stations it is recommended to include the entire station including the switch zone(s) and all station tracks. By including the switch...... zone(s) the possible conflicts with other trains (also in the opposite direction) are taken into account leading to more trustworthy results. Although the UIC 406 methodology proposes that the railway network should be divided into line sections when trains turn around and when the train order...... is changed, this paper recommends that the railway lines are not always be divided. In case trains turn around on open (single track) line, the capacity consumption may be too low if a railway line is divided. The same can be the case if only few trains are overtaken at an overtaking station. For dead end...

  17. Experimental investigation for the optimization of heat pipe performance in latent heat thermal storage

    Energy Technology Data Exchange (ETDEWEB)

    Ladekar, Chandrakishor; Choudhary, S. K. [RTM Nagpur University, Wardha (India); Khandare, S. S. [B. D. College of Engineering, Wardha (India)

    2017-06-15

    We investigated the optimum performance of heat pipe in Latent heat thermal energy storage (LHTES), and compared it with copper pipe. Classical plan of experimentation was used to optimize the parameters of heat pipe. Heat pipe fill ratio, evaporator section length to condenser section length ratio i.e., Heat pipe length ratio (HPLR) and heat pipe diameter, was the parameter used for optimization, as result of parametric analysis. Experiment with flow rate of 10 lit./min. was conducted for different fill ratio, HPLR and different diameter. Fill ratio of 80 %, HPLR of 0.9 and heat pipe with diameter of 18 mm showed better trend in charging and discharging. Comparison between the storage tank with optimized heat pipe and copper pipe showed almost 186 % improvement in charging and discharging time compared with the copper pipe embedded thermal storage. Heat transfer between Heat transferring fluid (HTF) and Phase change material (PCM) increased with increase in area of heat transferring media, but storage density of storage tank decreased. Storage tank with heat pipe embedded in place of copper pipe is a better option in terms of charging and discharging time as well heat storage capacity due to less heat lost. This justifies the better efficiency and effectiveness of storage tank with embedded optimized heat pipe.

  18. Transient Analysis of a Magnetic Heat Pump

    Science.gov (United States)

    Schroeder, E. A.

    1985-01-01

    An experimental heat pump that uses a rare earth element as the refrigerant is modeled using NASTRAN. The refrigerant is a ferromagnetic metal whose temperature rises when a magnetic field is applied and falls when the magnetic field is removed. The heat pump is used as a refrigerator to remove heat from a reservoir and discharge it through a heat exchanger. In the NASTRAN model the components modeled are represented by one-dimensional ROD elements. Heat flow in the solids and fluid are analyzed. The problem is mildly nonlinear since the heat capacity of the refrigerant is temperature-dependent. One simulation run consists of a series of transient analyses, each representing one stroke of the heat pump. An auxiliary program was written that uses the results of one NASTRAN analysis to generate data for the next NASTRAN analysis.

  19. Heat convection

    Energy Technology Data Exchange (ETDEWEB)

    Jiji, L.M. [City Univ. of New York, NY (United States). Dept. of Mechanical Engineering

    2006-07-01

    Professor Jiji's broad teaching experience lead him to select the topics for this book to provide a firm foundation for convection heat transfer with emphasis on fundamentals, physical phenomena, and mathematical modelling of a wide range of engineering applications. Reflecting recent developments, this textbook is the first to include an introduction to the challenging topic of microchannels. The strong pedagogic potential of Heat Convection is enhanced by the following ancillary materials: (1) Power Point lectures, (2) Problem Solutions, (3) Homework Facilitator, and, (4) Summary of Sections and Chapters. (orig.)

  20. Temperatures and Heat Flows in a Soil Enclosing a Slinky Horizontal Heat Exchanger

    OpenAIRE

    Pavel Neuberger; Radomír Adamovský; Michaela Šeďová

    2014-01-01

    Temperature changes and heat flows in soils that host “slinky”-type horizontal heat exchangers are complex, but need to be understood if robust quantification of the thermal energy available to a ground-source heat pump is to be achieved. Of particular interest is the capacity of the thermal energy content of the soil to regenerate when the heat exchangers are not operating. Analysis of specific heat flows and the specific thermal energy regime within the soil, including that captured by the ...

  1. Heat-Related Illnesses

    Medline Plus

    Full Text Available ... for signs of heat stroke or exhaustion. Heat Stroke and Exhaustion Symptoms of early heat exhaustion symptoms ... heavy sweating; nausea; and giddiness. Symptoms of heat stroke (late stage of heat illness) include flushed, hot, ...

  2. Renewable Heating and Cooling

    Science.gov (United States)

    Renewable heating and cooling is a set of alternative resources and technologies that can be used in place of conventional heating and cooling technologies for common applications such as water heating, space heating, space cooling and process heat.

  3. Global risk of deadly heat

    Science.gov (United States)

    Mora, Camilo; Dousset, Bénédicte; Caldwell, Iain R.; Powell, Farrah E.; Geronimo, Rollan C.; Bielecki, Coral R.; Counsell, Chelsie W. W.; Dietrich, Bonnie S.; Johnston, Emily T.; Louis, Leo V.; Lucas, Matthew P.; McKenzie, Marie M.; Shea, Alessandra G.; Tseng, Han; Giambelluca, Thomas W.; Leon, Lisa R.; Hawkins, Ed; Trauernicht, Clay

    2017-07-01

    Climate change can increase the risk of conditions that exceed human thermoregulatory capacity. Although numerous studies report increased mortality associated with extreme heat events, quantifying the global risk of heat-related mortality remains challenging due to a lack of comparable data on heat-related deaths. Here we conducted a global analysis of documented lethal heat events to identify the climatic conditions associated with human death and then quantified the current and projected occurrence of such deadly climatic conditions worldwide. We reviewed papers published between 1980 and 2014, and found 783 cases of excess human mortality associated with heat from 164 cities in 36 countries. Based on the climatic conditions of those lethal heat events, we identified a global threshold beyond which daily mean surface air temperature and relative humidity become deadly. Around 30% of the world's population is currently exposed to climatic conditions exceeding this deadly threshold for at least 20 days a year. By 2100, this percentage is projected to increase to ~48% under a scenario with drastic reductions of greenhouse gas emissions and ~74% under a scenario of growing emissions. An increasing threat to human life from excess heat now seems almost inevitable, but will be greatly aggravated if greenhouse gases are not considerably reduced.

  4. Measurement and Evaluation of Heating Performance of Heat Pump Systems Using Wasted Heat from Electric Devices for an Electric Bus

    Directory of Open Access Journals (Sweden)

    Moo-Yeon Lee

    2012-03-01

    Full Text Available The objective of this study is to investigate heating performance characteristics of a coolant source heat pump using the wasted heat from electric devices for an electric bus. The heat pump, using R-134a, is designed for heating a passengers’ compartment by using discharged energy from the coolant of electric devices, such as motors and inverters of the electric bus. The heating performance of the heat pump was tested by varying the operating parameters, such as outdoor temperature and volume flow rate of the coolant water of the electrical devices. Heating capacity, compressor work, and heating COP were measured; their behaviors with regard to the parameters were observed. Experimental results showed that heating COP increased with decrease of outdoor temperature, from 20.0 °C to 0 °C, and it observed to be 3.0 in the case of 0 °C outdoor temperature. The observed characteristics of the heating COP suggest that the heat pump is applicable as the cabin heater of an electric vehicle, which is limited by short driving range.

  5. Transient thermal camouflage and heat signature control

    Science.gov (United States)

    Yang, Tian-Zhi; Su, Yishu; Xu, Weikai; Yang, Xiao-Dong

    2016-09-01

    Thermal metamaterials have been proposed to manipulate heat flux as a new way to cloak or camouflage objects in the infrared world. To date, however, thermal metamaterials only operate in the steady-state and exhibit detectable, transient heat signatures. In this letter, the theoretical basis for a thermal camouflaging technique with controlled transient diffusion is presented. This technique renders an object invisible in real time. More importantly, the thermal camouflaging device instantaneously generates a pre-designed heat signature and behaves as a perfect thermal illusion device. A metamaterial coating with homogeneous and isotropic thermal conductivity, density, and volumetric heat capacity was fabricated and very good camouflaging performance was achieved.

  6. Infrared heating

    Science.gov (United States)

    IR heating was first industrially used in the 1930s for automotive curing applications and rapidly became a widely applied technology in the manufacturing industry. Contrarily, a slower pace in the development of IR technologies for processing foods and agricultural products was observed, due to lim...

  7. Markets and Institutional Capacity

    DEFF Research Database (Denmark)

    Ingemann, Jan Holm

    2010-01-01

    Adequate explanations concerning the introduction of production and consumption of organic food in Denmark imply the necessity to engage a certain understanding of markets. Markets should subsequently not be seen as entities nor places but as complex relations between human actors. Further......, the establishment, maintenance and development of markets are depending on the capacity of the actors to enter into continuous and enhancing interplay....

  8. Vedr.: Military capacity building

    DEFF Research Database (Denmark)

    Larsen, Josefine Kühnel; Struwe, Lars Bangert

    2013-01-01

    Kühnel Larsen and researcher Lars Bangert Struwe of CMS had organized a seminar in collaboration with Royal Danish Defense Colleg and the East African Security Governance Network. The seminar focused on some of the risks involved in Military capacity building and how these risks are dealt with from...

  9. Testamentary capacity and delirium.

    Science.gov (United States)

    Liptzin, Benjamin; Peisah, Carmelle; Shulman, Kenneth; Finkel, Sanford

    2010-09-01

    With the aging of the population there will be a substantial transfer of wealth in the next 25 years. The presence of delirium can complicate the evaluation of an older person's testamentary capacity and susceptibility to undue influence but has not been well examined in the existing literature. A subcommittee of the IPA Task Force on Testamentary Capacity and Undue Influence undertook to review how to assess prospectively and retrospectively testamentary capacity and susceptibility to undue influence in patients with delirium. The subcommittee identified questions that should be asked in cases where someone changes their will or estate plan towards the end of their life in the presence of delirium. These questions include: was there consistency in the patient's wishes over time? Were these wishes expressed during a "lucid interval" when the person was less confused? Were the patient's wishes clearly expressed in response to open-ended questions? Is there clear documentation of the patient's mental status at the time of the discussion? This review with some case examples provides guidance on how to consider the question of testamentary capacity or susceptibility to undue influence in someone undergoing an episode of delirium.

  10. Capacity Utilization in European Railways

    DEFF Research Database (Denmark)

    Khadem Sameni, Melody; Landex, Alex

    2013-01-01

    railways are facing a capacity challenge which is caused by passenger and freight demand exceeding the track capacity supply. In the absence of a comprehensive railway capacity manual, methodologies are needed to assess how well railways use their track capacity. This paper presents a novel...

  11. New and future heat pump technologies

    Science.gov (United States)

    Creswick, F. A.

    It is not possible to say for sure what future heat pumps will look like, but there are some interesting possibilities. In the next five years, we are likely to see US heat pumps with two kinds of innovations: capacity modulation and charge control. Capacity modulation will be accomplished by variable-speed compressor motors. The objective of charge control is to keep the refrigerant charge in the system where it belongs for best performance; there are probably many ways to accomplish this. Charge control will improve efficiency and durability; capacity modulation will further improve efficiency and comfort. The Stirling cycle heat pump has several interesting advantages, but it is farther out in time. At present, we don't know how to make it as efficient as the conventional vapor-compression heat pump. Electric utility people should be aware that major advances are being made in gas-fired heat pumps which could provide strong competition in the future. However, even a gas-fired heat pump has a substantial auxiliary electric power requirement. The resources needed to develop advanced heat pumps are substantial and foreign competition will be intense. It will be important for utilities, manufacturers, and the federal government to work in close cooperation.

  12. Cold Climate Heat Pumps Using Tandem Compressors

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Bo [ORNL; Abdelaziz, Omar [ORNL; Rice, C Keith [ORNL; Baxter, Van D [ORNL

    2016-01-01

    In cold climate zones, e.g. ASHRAE climate regions IV and V, conventional electric air-source heat pumps (ASHP) do not work well, due to high compressor discharge temperatures, large pressure ratios and inadequate heating capacities at low ambient temperatures. Consequently, significant use of auxiliary strip heating is required to meet the building heating load. We introduce innovative ASHP technologies as part of continuing efforts to eliminate auxiliary strip heat use and maximize heating COP with acceptable cost-effectiveness and reliability. These innovative ASHP were developed using tandem compressors, which are capable of augmenting heating capacity at low temperatures and maintain superior part-load operation efficiency at moderate temperatures. Two options of tandem compressors were studied; the first employs two identical, single-speed compressors, and the second employs two identical, vapor-injection compressors. The investigations were based on system modeling and laboratory evaluation. Both designs have successfully met the performance criteria. Laboratory evaluation showed that the tandem, single-speed compressor ASHP system is able to achieve heating COP = 4.2 at 47 F (8.3 C), COP = 2.9 at 17 F (-8.3 C), and 76% rated capacity and COP = 1.9 at -13 F (-25 C). This yields a HSPF = 11.0 (per AHRI 210/240). The tandem, vapor-injection ASHP is able to reach heating COP = 4.4 at 47 F, COP = 3.1 at 17 F, and 88% rated capacity and COP = 2.0 at -13 F. This yields a HSPF = 12.0. The system modeling and further laboratory evaluation are presented in the paper.

  13. Heat pump

    OpenAIRE

    Klíma, Martin

    2010-01-01

    Bakalářská práce popisuje a charakterizuje tepelné čerpadlo. Obsahuje souhrn jednotlivých druhů tepelných čerpadel z hlediska získávání energie, princip jejich funkce a popis odlišností mezi jednotlivými druhy kompresorů, použití pracovní látky a její vývin do budoucna. Závěrem je zde uveden můj vlastní názor na tepelné čerpadlo, které bych preferoval. Bachelor thesis describes and characterizes the heat pump. Summarizes the various types of heat pumps in terms of energy production, princi...

  14. District heating biofuel burner efficiency and energy balance

    OpenAIRE

    Okoro, Oluwashola Aderemi

    2015-01-01

    District heating is an optimal system of distributing heat to residential building in a centralized location through pipeline networks. The district heating of woodchip is cost effective, improve energy efficiency, reduce gas emissions and improve energy security. The thermal efficiency and energy balance in a boiler is obtained by combustion analysis of the wood (fuel). In this report, the district heating bio fuel burner in Skien Fjernvarme is considered. The capacity of the boiler is 6MW a...

  15. Identification of thermophysical characteristics of materials using heating probe

    OpenAIRE

    Abdelaziz Nasr; Abdulmajeed S. Al-Ghamdi; Mohammad S. Alsoufi

    2016-01-01

    This paper investigates the numerical analysis to determine the thermo-physical characteristics of materials. This method is based on a heating probe kept at a constant temperature and maintained in contact with a cylindrical sample. The heat power dissipated in the sample is measured by the probe. The results address to identify simultaneously the thermal conductivity, the volumetric heat capacity and the heat transfer coefficient using the inverse problem.

  16. Method of calculating heat transfer in furnaces of small power

    Directory of Open Access Journals (Sweden)

    Khavanov Pavel

    2016-01-01

    Full Text Available This publication presents the experiences and results of generalization criterion equation of importance in the analysis of the processes of heat transfer and thermal calculations of low-power heat generators cooled combustion chambers. With generalizing depending estimated contribution of radiation and convective heat transfer component in the complex for the combustion chambers of small capacity boilers. Determined qualitative and quantitative dependence of the integrated radiative-convective heat transfer from the main factors working combustion chambers of small volume.

  17. Heat Exchange

    OpenAIRE

    Bottomley, Stephen

    2012-01-01

    Heat Exchange’ is an international touring exhibition of enamel metalwork curated by Turrell.E (UK), Gegenwart (Germany/UK) and Cameron (Australia). Bottomley was one of twenty-three international artists invited to join a transcontinental on-line blog and forum that recorded individual contemporary approaches to working with vitreous enamel the year prior to the 2012 exhibition that coincided with the SNAG (Society of North American Goldsmiths) National Conference in Phoenix Arizona USA.Vitr...

  18. Revisiting Absorptive Capacity

    DEFF Research Database (Denmark)

    de Araújo, Ana Luiza Lara; Ulhøi, John Parm; Lettl, Christopher

    Absorptive capacity has mostly been perceived as a 'passive' outcome of R&D investments. Recently, however, a growing interest into its 'proactive' potentials has emerged. This paper taps into this development and proposes a dynamic model for conceptualizing the determinants of the complementary ...... processes, with emphasis on exploitative learning. Before concluding, the paper addresses implications for theory and practice and limitations of this study....

  19. Capacity building in Nepal*

    OpenAIRE

    Dawe, Russell; Stobbe, Karl; Pokharel, Yagya Raj; Shrestha, Shrijana

    2016-01-01

    Healthcare providers from high-income countries often want to help underserved populations, but providing clinical care is not always a sustainable approach. Patan Academy of Health Sciences (PAHS), in Nepal, has taken an innovative approach to capacity building in healthcare. PAHS has partnered with rural family doctors from Canada to provide clinical bedside teaching to medical students in PAHS’s rural program, thereby making a sustainable contribution to healthcare in Nepal.

  20. Capacity building in Nepal

    Directory of Open Access Journals (Sweden)

    Russell Eric Dawe

    2016-12-01

    Full Text Available Healthcare providers from high-income countries often want to help underserved populations, but providing clinical care is not always a sustainable approach. Patan Academy of Health Sciences (PAHS, in Nepal, has taken an innovative approach to capacity building in healthcare. PAHS has partnered with rural family doctors from Canada to provide clinical bedside teaching to medical students in PAHS’s rural program, thereby making a sustainable contribution to healthcare in Nepal.

  1. Weather and road capacity

    OpenAIRE

    Jensen, Thomas Christian

    2014-01-01

    The paper presents estimations of the effect of bad weather on the observed speed on a Danish highway section; Køge Bugt Motorvejen. The paper concludes that weather, primarily precipitation and snow, has a clear negative effect on speed when the road is not in hypercongestion mode. Furthermore, the capacity of the highway seems to be reduced in bad weather and there are indications that travel time variability is also increased, at least in free-flow conditions. Heavy precipitation reduces s...

  2. CSTI High Capacity Power

    Science.gov (United States)

    Winter, Jerry M.

    1989-01-01

    The SP-100 program was established in 1983 by DOD, DOE, and NASA as a joint program to develop the technology necessary for space nuclear power systems for military and civil application. During FY-86 and 87, the NASA SP-100 Advanced Technology Program was devised to maintain the momentum of promising technology advancement efforts started during Phase 1 of SP-100 and to strengthen, in key areas, the chances for successful development and growth capability of space nuclear reactor power systems for future space applications. In FY-88, the Advanced Technology Program was incorporated into NASA's new Civil Space Technology Initiative (CSTI). The CSTI Program was established to provide the foundation for technology development in automation and robotics, information, propulsion, and power. The CSTI High Capacity Power Program builds on the technology efforts of the SP-100 program, incorporates the previous NASA SP-100 Advanced Technology project, and provides a bridge to NASA Project Pathfinder. The elements of CSTI High Capacity Power development include Conversion Systems, Thermal Management, Power Management, System Diagnostics, and Environmental Interactions. Technology advancement in all areas, including materials, is required to assure the high reliability and 7 to 10 year lifetime demanded for future space nuclear power systems. The overall program will develop and demonstrate the technology base required to provide a wide range of modular power systems as well as allowing mission independence from solar and orbital attitude requirements. Several recent advancements in CSTI High Capacity power development will be discussed.

  3. Coupling heat and chemical tracer experiments for estimating heat transfer parameters in shallow alluvial aquifers.

    Science.gov (United States)

    Wildemeersch, S; Jamin, P; Orban, P; Hermans, T; Klepikova, M; Nguyen, F; Brouyère, S; Dassargues, A

    2014-11-15

    Geothermal energy systems, closed or open, are increasingly considered for heating and/or cooling buildings. The efficiency of such systems depends on the thermal properties of the subsurface. Therefore, feasibility and impact studies performed prior to their installation should include a field characterization of thermal properties and a heat transfer model using parameter values measured in situ. However, there is a lack of in situ experiments and methodology for performing such a field characterization, especially for open systems. This study presents an in situ experiment designed for estimating heat transfer parameters in shallow alluvial aquifers with focus on the specific heat capacity. This experiment consists in simultaneously injecting hot water and a chemical tracer into the aquifer and monitoring the evolution of groundwater temperature and concentration in the recovery well (and possibly in other piezometers located down gradient). Temperature and concentrations are then used for estimating the specific heat capacity. The first method for estimating this parameter is based on a modeling in series of the chemical tracer and temperature breakthrough curves at the recovery well. The second method is based on an energy balance. The values of specific heat capacity estimated for both methods (2.30 and 2.54MJ/m(3)/K) for the experimental site in the alluvial aquifer of the Meuse River (Belgium) are almost identical and consistent with values found in the literature. Temperature breakthrough curves in other piezometers are not required for estimating the specific heat capacity. However, they highlight that heat transfer in the alluvial aquifer of the Meuse River is complex and contrasted with different dominant process depending on the depth leading to significant vertical heat exchange between upper and lower part of the aquifer. Furthermore, these temperature breakthrough curves could be included in the calibration of a complex heat transfer model for

  4. Heat pump system

    Science.gov (United States)

    Swenson, Paul F.; Moore, Paul B.

    1979-01-01

    An air heating and cooling system for a building includes an expansion-type refrigeration circuit and a heat engine. The refrigeration circuit includes two heat exchangers, one of which is communicated with a source of indoor air from the building and the other of which is communicated with a source of air from outside the building. The heat engine includes a heat rejection circuit having a source of rejected heat and a primary heat exchanger connected to the source of rejected heat. The heat rejection circuit also includes an evaporator in heat exchange relation with the primary heat exchanger, a heat engine indoor heat exchanger, and a heat engine outdoor heat exchanger. The indoor heat exchangers are disposed in series air flow relationship, with the heat engine indoor heat exchanger being disposed downstream from the refrigeration circuit indoor heat exchanger. The outdoor heat exchangers are also disposed in series air flow relationship, with the heat engine outdoor heat exchanger disposed downstream from the refrigeration circuit outdoor heat exchanger. A common fluid is used in both of the indoor heat exchangers and in both of the outdoor heat exchangers. In a first embodiment, the heat engine is a Rankine cycle engine. In a second embodiment, the heat engine is a non-Rankine cycle engine.

  5. Energy efficient ammonia heat pump. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Madsen, Claus; Pijnenburg, B.; Schumann Grindorf, H. [Danish Technological Institute, Aarhus (Denmark); Christensen, Rolf [Alfa Laval, Lund (Sweden); Rasmussen, Bjarne D. [Grundfos, Bjerringbro (Denmark); Gram, S.; Fredborg Jakobsen, D. [Svedan Industri Koeleanlaeg, Greve (Denmark)

    2013-09-15

    The report describes the development of a highly effective ammonia heat pump. Heat pumps play an increasingly important role in the search for more effective use of energy in our society. Highly efficient heat pumps can contribute to reduced energy consumption and improved economy of the systems which they are a part of. An ammonia heat pump with high pressure reciprocating compressor and a novel split condenser was developed to prove potential for efficiency optimization. The split of the condenser in two parts can be utilized to obtain smaller temperature approaches and, thereby, improved heat pump efficiency at an equal heat exchanger area, when compared to the traditional solution with separate condenser and de-superheater. The split condenser design can also be exploited for heating a significant share of the total heating capacity to a temperature far above the condensing temperature. Furthermore, the prototype heat pump was equipped with a plate type evaporator combined with a U-turn separator with a minimum liquid height and a liquid pump with the purpose of creating optimum liquid circulation ratio for the highest possible heat transfer coefficients at the lowest possible pressure drop. The test results successfully confirmed the highest possible efficiency; a COP of 4.3 was obtained when heating water from 40 deg. C to 80 deg. C while operating with evaporating/condensing temperatures of +20 deg C/+73 deg C. (Author)

  6. Heat-Exchanger/Heat-Pipe Interface

    Science.gov (United States)

    Snyder, H. J.; Van Hagan, T. H.

    1987-01-01

    Monolithic assembly reliable and light in weight. Heat exchanger and evaporator ends of heat pipes integrated in monolithic halves welded together. Interface assembly connects heat exchanger of furnace, reactor, or other power source with heat pipes carrying heat to radiator or power-consuming system. One of several concepts proposed for nuclear power supplies aboard spacecraft, interface useful on Earth in solar thermal power systems, heat engines, and lightweight cooling systems.

  7. Optimization of Solar Water Heating System under Time and Spatial Partition Heating in Rural Dwellings

    Directory of Open Access Journals (Sweden)

    Yanfeng Liu

    2017-10-01

    Full Text Available This paper proposes the application of time and spatial partition heating to a solar water heating system. The heating effect and system performance were analyzed under the continuous and whole space heating and time and spatial partition heating using TRNSYS. The results were validated by comparing with the test results of the demonstration building. Compared to continuous and whole space heating, the use of time and spatial partition heating increases the solar fraction by 16.5%, reduces the auxiliary heating by 7390 MJ, and reduces the annual operation cost by 2010 RMB. Under time and spatial partition heating, optimization analyses were conducted for the two system capacity parameters of the solar collector area and tank volume and the one operation parameter of auxiliary heater setting outlet temperature. The results showed that a reasonable choice of the solar collector area can reduce the dynamic annual cost, the increased tank volume is advantageous to heat storage, and the auxiliary heater setting outlet temperature have greater influence on the indoor heating effect. The advanced opening of solar water heating system and the normal opening of passive air vents are recommended. Based on the comparison of the two modes, the time and spatial partition heating technology is a better choice for rural dwellings.

  8. Field Performance of Heat Pump Water Heaters in the Northeast

    Energy Technology Data Exchange (ETDEWEB)

    Shapiro, Carl [Consortium for Advanced Residential Buildings, Norwalk, CT (United States); Puttagunta, Srikanth [Consortium for Advanced Residential Buildings, Norwalk, CT (United States)

    2016-02-01

    Heat pump water heaters (HPWHs) are finally entering the mainstream residential water heater market. Potential catalysts are increased consumer demand for higher energy efficiency electric water heating and a new Federal water heating standard that effectively mandates use of HPWHs for electric storage water heaters with nominal capacities greater than 55 gallons. When compared to electric resistance water heating, the energy and cost savings potential of HPWHs is tremendous. Converting all electric resistance water heaters to HPWHs could save American consumers 7.8 billion dollars annually ($182 per household) in water heating operating costs and cut annual residential source energy consumption for water heating by 0.70 quads.

  9. Heating systems for heating subsurface formations

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, Scott Vinh [Houston, TX; Vinegar, Harold J [Bellaire, TX

    2011-04-26

    Methods and systems for heating a subsurface formation are described herein. A heating system for a subsurface formation includes a sealed conduit positioned in an opening in the formation and a heat source. The sealed conduit includes a heat transfer fluid. The heat source provides heat to a portion of the sealed conduit to change phase of the heat transfer fluid from a liquid to a vapor. The vapor in the sealed conduit rises in the sealed conduit, condenses to transfer heat to the formation and returns to the conduit portion as a liquid.

  10. Hydride heat pump with heat regenerator

    Science.gov (United States)

    Jones, Jack A. (Inventor)

    1991-01-01

    A regenerative hydride heat pump process and system is provided which can regenerate a high percentage of the sensible heat of the system. A series of at least four canisters containing a lower temperature performing hydride and a series of at least four canisters containing a higher temperature performing hydride is provided. Each canister contains a heat conductive passageway through which a heat transfer fluid is circulated so that sensible heat is regenerated. The process and system are useful for air conditioning rooms, providing room heat in the winter or for hot water heating throughout the year, and, in general, for pumping heat from a lower temperature to a higher temperature.

  11. Analysis of Effect of Heat Pipe Parameters in Minimising the Entropy Generation Rate

    OpenAIRE

    Rakesh Hari; Chandrasekharan Muraleedharan

    2016-01-01

    Heat transfer and fluid flow in the heat pipe system result in thermodynamic irreversibility generating entropy. The minimum entropy generation principle can be used for optimum design of flat heat pipe. The objective of the present work is to minimise the total entropy generation rate as the objective function with different parameters of the flat heat pipe subjected to some constraints. These constraints constitute the limitations on the heat transport capacity of the heat pipe. This physic...

  12. Waste heat recovery system

    Energy Technology Data Exchange (ETDEWEB)

    Ernst, Timothy C.; Zigan, James A.

    2017-12-19

    A waste heat recovery system includes a Rankine cycle (RC) circuit having a pump, a boiler, an energy converter, and a condenser fluidly coupled via conduits in that order, to provide additional work. The additional work is fed to an input of a gearbox assembly including a capacity for oil by mechanically coupling to the energy converter to a gear assembly. An interface is positioned between the RC circuit and the gearbox assembly to partially restrict movement of oil present in the gear assembly into the RC circuit and partially restrict movement of working fluid present in the RC circuit into the gear assembly. An oil return line is fluidly connected to at least one of the conduits fluidly coupling the RC components to one another and is operable to return to the gear assembly oil that has moved across the interface from the gear assembly to the RC circuit.

  13. Consensus recommendations on training and competing in the heat

    DEFF Research Database (Denmark)

    Racinais, Sebastien; Alonso, J M; Coutts, A J

    2015-01-01

    Exercising in the heat induces thermoregulatory and other physiological strain that can lead to impairments in endurance exercise capacity. The purpose of this consensus statement is to provide up-to-date recommendations to optimise performance during sporting activities undertaken in hot ambient...... and minimise dehydration during exercise. Following the development of commercial cooling systems (eg, cooling-vest), athletes can implement cooling strategies to facilitate heat loss or increase heat storage capacity before training or competing in the heat. Moreover, event organisers should plan for large...

  14. Development of seasonal heat storage based on stable supercooling of a sodium acetate water mixture

    DEFF Research Database (Denmark)

    Furbo, Simon; Fan, Jianhua; Andersen, Elsa

    2012-01-01

    to and from the sodium acetate water mixture in the modules. By means of the experiments: • The heat exchange capacity rates to and from the sodium acetate water mixture in the heat storage modules were determined for different volume flow rates. • The heat content of the heat storage modules were determined...

  15. Heat pipes

    CERN Document Server

    Dunn, Peter D

    1982-01-01

    A comprehensive, up-to-date coverage of the theory, design and manufacture of heat pipes and their applications. This latest edition has been thoroughly revised, up-dated and expanded to give an in-depth coverage of the new developments in the field. Significant new material has been added to all the chapters and the applications section has been totally rewritten to ensure that topical and important applications are appropriately emphasised. The bibliography has been considerably enlarged to incorporate much valuable new information. Thus readers of the previous edition, which has established

  16. Heat-Related Illnesses

    Medline Plus

    Full Text Available ... Emergencies A-Z Share this! Home » Emergency 101 Heat-Related Illnesses Dr. Glenn Mitchell , Emergency physician at ... about heat cramps and heat stroke and exhaustion. Heat Cramps Symptoms include muscle spasms, usually in the ...

  17. Low temperature nuclear heat

    Energy Technology Data Exchange (ETDEWEB)

    Kotakorpi, J.; Tarjanne, R. (comps.)

    1977-08-01

    The meeting was concerned with the use of low grade nuclear heat for district heating, desalination, process heat, and agriculture and aquaculture. The sessions covered applications and demand, heat sources, and economics.

  18. Regenerative Hydride Heat Pump

    Science.gov (United States)

    Jones, Jack A.

    1992-01-01

    Hydride heat pump features regenerative heating and single circulation loop. Counterflow heat exchangers accommodate different temperatures of FeTi and LaNi4.7Al0.3 subloops. Heating scheme increases efficiency.

  19. Experimental Research On Gas Injection High Temperature Heat Pump With An Economizer

    OpenAIRE

    He, Yongning; Jin, Lei; Cao, Feng; Chen, Shengkun

    2014-01-01

    Gas injection technology is often used in cold regions to solve heat pump’s low heating capacity and high discharge temperature at low ambient temperature. Injecting gas into port opened at specific position of compressor could increase mass flow rate of compressor and total heating capacity of heat pump. Gas injection also changes compression ratio of compressor and decreases discharge temperature. An optimal gas injection pressure is got when the coefficient of performance reached to peak v...

  20. Integration of large-scale heat pumps in the district heating systems of Greater Copenhagen

    DEFF Research Database (Denmark)

    Bach, Bjarne; Werling, Jesper; Ommen, Torben Schmidt

    2016-01-01

    This study analyses the technical and private economic aspects of integrating a large capacity of electric driven HP (heat pumps) in the Greater Copenhagen DH (district heating) system, which is an example of a state-of-the-art large district heating system with many consumers and suppliers....... The analysis was based on using the energy model Balmorel to determine the optimum dispatch of HPs in the system. The potential heat sources in Copenhagen for use in HPs were determined based on data related to temperatures, flows, and hydrography at different locations, while respecting technical constraints...

  1. Heat transfer performance of an oscillating heat pipe under ultrasonic field with dual frequency

    Science.gov (United States)

    Fu, B. W.; Zhao, N. N.; Ma, H. B.; Su, F. M.

    2015-01-01

    The oscillating motion and heat transfer capacity in an oscillating heat pipe (OHP) under the effect of ultrasound was investigated experimentally. Using the electrically- controlled piezoelectric ceramics, the ultrasonic sound was applied to the evaporating section of the OHP. The heat pipe was tested with or without the ultrasonic sound. The effect of ultrasound on the heat transfer performance was conducted with ultrasound of single frequency or dual frequency. The experimental results demonstrate that the OHP under the effect of the ultrasonic sound with dual frequency performs better than that one with single frequency.

  2. Deficiency of employability capacity

    Directory of Open Access Journals (Sweden)

    Pelse I.

    2012-10-01

    Full Text Available Young unemployed people have comprised one of the significantly largest groups of the unemployed people in Latvia in recent years. One of the reasons why young people have difficulty integrating into the labour market is the “expectation gap” that exists in the relations between employers and the new generation of workers. Employers focus on capacity-building for employability such individual factors as strength, patience, self-discipline, self-reliance, self-motivation, etc., which having a nature of habit and are developed in a long-term work socialization process, which begins even before the formal education and will continue throughout the life cycle. However, when the socialization is lost, these habits are depreciated faster than they can be restored. Currently a new generation is entering the labour market, which is missing the succession of work socialization. Factors, such as rising unemployment and poverty in the background over the past twenty years in Latvia have created a very unfavourable employability background of “personal circumstances” and “external factors”, which seriously have impaired formation of the skills and attitudes in a real work environment. The study reveals another paradox – the paradox of poverty. Common sense would want to argue that poverty can be overcome by the job. However, the real state of affairs shows that unfavourable coincidence of the individual, personal circumstances and external factors leads to deficit of employability capacity and possibility of marked social and employment deprivation.

  3. Early hominin auditory capacities.

    Science.gov (United States)

    Quam, Rolf; Martínez, Ignacio; Rosa, Manuel; Bonmatí, Alejandro; Lorenzo, Carlos; de Ruiter, Darryl J; Moggi-Cecchi, Jacopo; Conde Valverde, Mercedes; Jarabo, Pilar; Menter, Colin G; Thackeray, J Francis; Arsuaga, Juan Luis

    2015-09-01

    Studies of sensory capacities in past life forms have offered new insights into their adaptations and lifeways. Audition is particularly amenable to study in fossils because it is strongly related to physical properties that can be approached through their skeletal structures. We have studied the anatomy of the outer and middle ear in the early hominin taxa Australopithecus africanus and Paranthropus robustus and estimated their auditory capacities. Compared with chimpanzees, the early hominin taxa are derived toward modern humans in their slightly shorter and wider external auditory canal, smaller tympanic membrane, and lower malleus/incus lever ratio, but they remain primitive in the small size of their stapes footplate. Compared with chimpanzees, both early hominin taxa show a heightened sensitivity to frequencies between 1.5 and 3.5 kHz and an occupied band of maximum sensitivity that is shifted toward slightly higher frequencies. The results have implications for sensory ecology and communication, and suggest that the early hominin auditory pattern may have facilitated an increased emphasis on short-range vocal communication in open habitats.

  4. Early hominin auditory capacities

    Science.gov (United States)

    Quam, Rolf; Martínez, Ignacio; Rosa, Manuel; Bonmatí, Alejandro; Lorenzo, Carlos; de Ruiter, Darryl J.; Moggi-Cecchi, Jacopo; Conde Valverde, Mercedes; Jarabo, Pilar; Menter, Colin G.; Thackeray, J. Francis; Arsuaga, Juan Luis

    2015-01-01

    Studies of sensory capacities in past life forms have offered new insights into their adaptations and lifeways. Audition is particularly amenable to study in fossils because it is strongly related to physical properties that can be approached through their skeletal structures. We have studied the anatomy of the outer and middle ear in the early hominin taxa Australopithecus africanus and Paranthropus robustus and estimated their auditory capacities. Compared with chimpanzees, the early hominin taxa are derived toward modern humans in their slightly shorter and wider external auditory canal, smaller tympanic membrane, and lower malleus/incus lever ratio, but they remain primitive in the small size of their stapes footplate. Compared with chimpanzees, both early hominin taxa show a heightened sensitivity to frequencies between 1.5 and 3.5 kHz and an occupied band of maximum sensitivity that is shifted toward slightly higher frequencies. The results have implications for sensory ecology and communication, and suggest that the early hominin auditory pattern may have facilitated an increased emphasis on short-range vocal communication in open habitats. PMID:26601261

  5. The influence of heat sink temperature on the seasonal efficiency of shallow geothermal heat pumps

    Science.gov (United States)

    Pełka, Grzegorz; Luboń, Wojciech; Sowiżdżał, Anna; Malik, Daniel

    2017-11-01

    Geothermal heat pumps, also known as ground source heat pumps (GSHP), are the most efficient heating and cooling technology utilized nowadays. In the AGH-UST Educational and Research Laboratory of Renewable Energy Sources and Energy Saving in Miękinia, shallow geothermal heat is utilized for heating. In the article, the seasonal efficiency of two geothermal heat pump systems are described during the 2014/2015 heating season, defined as the period between 1st October 2014 and 30th April 2015. The first system has 10.9 kW heating capacity (according to European Standard EN 14511 B0W35) and extracts heat from three vertical geothermal loops at a depth of 80m each. During the heating season, tests warmed up the buffer to 40°C. The second system has a 17.03 kW heating capacity and extracts heat from three vertical geothermal loops at a depth of 100 m each, and the temperature of the buffer was 50°C. During the entire heating season, the water temperatures of the buffers was constant. Seasonal performance factors were calculated, defined as the quotient of heat delivered by a heat pump to the system and the sum of electricity consumed by the compressor, source pump, sink pump and controller of heat pumps. The measurements and calculations give the following results: - The first system was supplied with 13 857 kWh/a of heat and consumed 3 388 kWh/a electricity. The SPF was 4.09 and the average temperature of outlet water from heat pump was 40.8°C, and the average temperature of brine flows into the evaporator was 3.7 °C; - The second system was supplied with 12 545 kWh/a of heat and consumed 3 874 kWh/a electricity. The SPF was 3.24 and the average temperature of outlet water from heat pump was 51.6°C, and the average temperature of brine flows into the evaporator was 5.3°C. To summarize, the data shown above presents the real SPF of the two systems. It will be significant in helping to predict the SPF of objects which will be equipped with ground source heat pumps.

  6. Workshop on moisture buffer capacity

    DEFF Research Database (Denmark)

    2003-01-01

    Summary report of a Nordtest workshop on moisture buffer capacity held at Copenhagen August 21-22 2003......Summary report of a Nordtest workshop on moisture buffer capacity held at Copenhagen August 21-22 2003...

  7. High temperature active heat exchanger research for latent heat storage

    Science.gov (United States)

    Alario, J.; Haslett, R.

    1982-02-01

    An active heat exchange method in a latent heat (salt) thermal energy storage system that prevents a low conductivity solid salt layer from forming on heat transfer surfaces was developed. An evaluation of suitable media with melting points in the temperature range of interest (250 to 400 C) limited the candidates to molten salts from the chloride, hydroxide and nitrate families, based on high storage capacity, good corrosion characteristics and availability in large quantities at reasonable cost. The specific salt recommended for laboratory tests was a choride eutectic (20.5KCL o 24.5NaCL o 55.MgCl2% by wt.), with a nominal melting point of 385 C. Various active heat exchange concepts were given a technical and economic comparison to a passive tube shell design for a reference application (300 MW sub t for 6 hours). Test hardware was then built for the most promising concept: a direct contact heat exchanger in which molten salt droplets are injected into a cooler counter flowing stream of liquid metal carrier fluid (lead/Bismuth).

  8. Segmented heat exchanger

    Science.gov (United States)

    Baldwin, Darryl Dean; Willi, Martin Leo; Fiveland, Scott Byron; Timmons, Kristine Ann

    2010-12-14

    A segmented heat exchanger system for transferring heat energy from an exhaust fluid to a working fluid. The heat exchanger system may include a first heat exchanger for receiving incoming working fluid and the exhaust fluid. The working fluid and exhaust fluid may travel through at least a portion of the first heat exchanger in a parallel flow configuration. In addition, the heat exchanger system may include a second heat exchanger for receiving working fluid from the first heat exchanger and exhaust fluid from a third heat exchanger. The working fluid and exhaust fluid may travel through at least a portion of the second heat exchanger in a counter flow configuration. Furthermore, the heat exchanger system may include a third heat exchanger for receiving working fluid from the second heat exchanger and exhaust fluid from the first heat exchanger. The working fluid and exhaust fluid may travel through at least a portion of the third heat exchanger in a parallel flow configuration.

  9. Dual source heat pump

    Science.gov (United States)

    Ecker, Amir L.; Pietsch, Joseph A.

    1982-01-01

    What is disclosed is a heat pump apparatus for conditioning a fluid characterized by a fluid handler and path for circulating the fluid in heat exchange relationship with a refrigerant fluid; at least two refrigerant heat exchangers, one for effecting heat exchange with the fluid and a second for effecting heat exchange between refrigerant and a heat exchange fluid and the ambient air; a compressor for efficiently compressing the refrigerant; at least one throttling valve for throttling liquid refrigerant; a refrigerant circuit; refrigerant; a source of heat exchange fluid; heat exchange fluid circulating device and heat exchange fluid circuit for circulating the heat exchange fluid in heat exchange relationship with the refrigerant; and valves or switches for selecting the heat exchangers and direction of flow of the refrigerant therethrough for selecting a particular mode of operation. The heat exchange fluid provides energy for defrosting the second heat exchanger when operating in the air source mode and also provides a alternate source of heat.

  10. Capacity enhancement of indigenous expansion engine based helium liquefier

    Science.gov (United States)

    Doohan, R. S.; Kush, P. K.; Maheshwari, G.

    2017-02-01

    Development of technology and understanding for large capacity helium refrigeration and liquefaction at helium temperature is indispensable for coming-up projects. A new version of helium liquefier designed and built to provide approximately 35 liters of liquid helium per hour. The refrigeration capacity of this reciprocating type expansion engine machine has been increased from its predecessor version with continuous improvement and deficiency debugging. The helium liquefier has been built using components by local industries including cryogenic Aluminum plate fin heat exchangers. Two compressors with nearly identical capacity have been deployed for the operation of system. Together they consume about 110 kW of electric power. The system employs liquid Nitrogen precooling to enhance liquid Helium yield. This paper describes details of the cryogenic expander design improvements, reconfiguration of heat exchangers, performance simulation and their experimental validation.

  11. Landfill Construction and Capacity Expansion

    NARCIS (Netherlands)

    Andre, F.J.; Cerda, E.

    2003-01-01

    We study the optimal capacity and lifetime of landfills taking into account their sequential nature.Such an optimal capacity is characterized by the so-called Optimal Capacity Condition.Particular versions of this condition are obtained for two alternative settings: first, if all the landfills are

  12. Research projects and capacity building

    African Journals Online (AJOL)

    driniev

    2004-10-04

    Oct 4, 2004 ... and capacity to adapt to change (Senge, 1990; Barth and Bartenstein,. 1998; Davenport et al., 1998; Senge et al., ... ing catchment management through enhanced stakeholder participa- tion. The special emphasis on capacity .... Change and resistance to change. Building capacity involves change and ...

  13. To Selection of Small-Capacity Turbine Type and Rated Conditions

    Directory of Open Access Journals (Sweden)

    N. B. Karnitsky

    2010-01-01

    Full Text Available Profitability of industrial-heating boiler transition to mini-TPP is revealed in the paper. The paper presents a comparative analysis of high- and low-speed turbines of small capacity.

  14. Nonazeotropic Heat Pump

    Science.gov (United States)

    Ealker, David H.; Deming, Glenn

    1991-01-01

    Heat pump collects heat from water circulating in heat-rejection loop, raises temperature of collected heat, and transfers collected heat to water in separate pipe. Includes sealed motor/compressor with cooling coils, evaporator, and condenser, all mounted in outer housing. Gradients of temperature in evaporator and condenser increase heat-transfer efficiency of vapor-compression cycle. Intended to recover relatively-low-temperature waste heat and use it to make hot water.

  15. Unitary air-to-air heat pumps

    Energy Technology Data Exchange (ETDEWEB)

    Christian, J.E.

    1977-07-01

    This technology evaluation covers commercially available unitary heat pumps ranging from nominal capacities of 1/sup 1///sub 2/ to 45 tons. The nominal COP of the heat pump models, selected as representative, vary from 2.4 to 2.9. Seasonal COPs for heat pump installations and single-family dwellings are reported to vary from 2.5 to 1.1, depending on climate. For cooling performance, the nominal EER's vary from 6.5 to 8.7. Representative part-load performance curves along with cost estimating and reliability data are provided to aid: (1) the systems design engineer to select suitably sized heat pumps based on life-cycle cost analyses, and (2) the computer programmer to develop a simulation code for heat pumps operating in an Integrated Community Energy System.

  16. High heat flux single phase heat exchanger

    Science.gov (United States)

    Valenzuela, Javier A.; Izenson, Michael G.

    1990-01-01

    This paper presents the results obtained to date in a program to develop a high heat flux, single-phase heat exchanger for spacecraft thermal management. The intended application is a net generation interface heat exchanger to couple the crew module water thermal bus to the two-phase ammonia main thermal bus in the Space Station Freedom. The large size of the interface heat exchanger is dictated by the relatively poor water-side heat transfer characteristics. The objective of this program is to develop a single-phase heat transfer approach which can achieve heat fluxes and heat transfer coefficients comparable to those of the evaporation ammonia side. A new heat exchanger concept has been developed to meet these objecties. The main feature of this heat exchanger is that it can achieve very high heat fluxes with a pressure drop one to two orders of magnitude lower than those of previous microchannel or jet impingement high heat flux heat exchangers. This paper describes proof-of-concept experiments performed in air and water and presents analytical model of the heat exchanger.

  17. Capacity building for HIA

    Directory of Open Access Journals (Sweden)

    Gabriel Gulis PhD

    2007-09-01

    Full Text Available

    Background: To integrate health impact assessment (HIA into existing decision-making processes requires not only methods and procedures but also well-trained experts, aware policy makers and appropriate institutions. Capacity building is the assistance which is provided to entities, which have a need to develop a certain skill or competence, or for general upgrading of performance ability. If a new technique is planned to be introduced there is a need for capacity building with no respect to levels (local, regional, national, international or sectors (health, environment, finance, social care, education, etc.. As such, HIA is a new technique for most of the new Member States and accession countries of the European Union.

    Methods: To equip individuals with the understanding and skills needed to launch a HIA or be aware of the availability of this methodology and to access information, knowledge and training, we focused on the organization of workshops in participating countries. The workshops served also as pilot events to test a “curriculum” for HIA; a set of basic topics and presentations had been developed to be tested during workshops. In spite of classical in-class workshops we aimed to organize e-learning events as a way to over come the “busyness” problem of decision makers.

    Results: Throughout March – October 2006 we organized and ran 7 workshops in Denmark, Turkey, Lithuania, Poland, Bulgaria, Slovak Republic and Hungary. Participants came from the public health sector (141, non-public health decision makers (113 and public health students (100. A concise curriculum was developed and tested during these workshops. Participants developed a basic understanding of HIA, skills to develop and use their own screening tools as well as scoping.Within the workshop in Denmark we tested an online, real-time Internet based training method; participants highly welcomed this

  18. Multiple source heat pump

    Science.gov (United States)

    Ecker, Amir L.

    1983-01-01

    A heat pump apparatus for conditioning a fluid characterized by a fluid handler and path for circulating a fluid in heat exchange relationship with a refrigerant fluid, at least three refrigerant heat exchangers, one for effecting heat exchange with the fluid, a second for effecting heat exchange with a heat exchange fluid, and a third for effecting heat exchange with ambient air; a compressor for compressing the refrigerant; at least one throttling valve connected at the inlet side of a heat exchanger in which liquid refrigerant is vaporized; a refrigerant circuit; refrigerant; a source of heat exchange fluid; heat exchange fluid circuit and pump for circulating the heat exchange fluid in heat exchange relationship with the refrigerant; and valves or switches for selecting the heat exchangers and directional flow of refrigerant therethrough for selecting a particular mode of operation. Also disclosed are a variety of embodiments, modes of operation, and schematics therefor.

  19. Heat pump technology

    CERN Document Server

    Von Cube, Hans Ludwig; Goodall, E G A

    2013-01-01

    Heat Pump Technology discusses the history, underlying concepts, usage, and advancements in the use of heat pumps. The book covers topics such as the applications and types of heat pumps; thermodynamic principles involved in heat pumps such as internal energy, enthalpy, and exergy; and natural heat sources and energy storage. Also discussed are topics such as the importance of the heat pump in the energy industry; heat pump designs and systems; the development of heat pumps over time; and examples of practical everyday uses of heat pumps. The text is recommended for those who would like to kno

  20. Theoretical study of heat pump system using CO2/dimethylether as refrigerant

    Directory of Open Access Journals (Sweden)

    Fan Xiao-Wei

    2013-01-01

    Full Text Available Nowadays, HCFC22 is widely used in heat pump systems in China, which should be phased out in the future. Thus, eco-friendly mixture CO2/dimethylether is proposed to replace HCFC22. Compared with pure CO2 and pure dimethylether, the mixture can reduce the heat rejection pressure, and suppress the flammability and explosivity of pure dimethylether. According to the Chinese National Standards on heat pump water heater and space heating system, performances of the subcritical heat pump system are discussed and compared with those of the HCFC22 system. It can be concluded that CO2 /dimethylether mixture works efficiently as a refrigerant for heat pumps with a large heat-sink temperature rise. When mass fraction of dimethylether is increased, the heat rejection pressure is reduced. Under the nominal working condition, there is an optimal mixture mass fraction of 28/72 of CO2/dimethylether for water heater application under conventional condensation pressure, 3/97 for space heating application. For water heater application, both the heating coefficient of performance and volumetric heating capacity increase by 17.90% and 2.74%, respectively, compared with those of HCFC22 systems. For space heating application, the heating coefficient of performance increases by 8.44% while volumetric heating capacity decreases by 34.76%, compared with those of HCFC22 systems. As the superheat degree increases, both the heating coefficient of performance and volumetric heating capacity tend to decrease.

  1. CO2 as a heat pump working fluid for retrofitting hydronic heating systems in Western Europe

    Energy Technology Data Exchange (ETDEWEB)

    Enkemann, T.; Kruse, H. [FKW Research Center for Refrigeration and Heat Pumps, University of Hannover, Hannover (Germany); Oostendorp, P.A. [TNO Institute of Environmental Sciences, Energy Research and Process Innovation TNO-MEP, Apeldoorn (Netherlands)

    1998-12-31

    The use of heat pumps instead of conventional heating systems seems to be a promising way to reduce CO2 emissions contributing to the global warming impact in the field of space heating. Concerning the equipment of new buildings one can see a growing market for heat pumps in some cases due to governmental supporting measures. Since the number of existing buildings is much higher than the number of new buildings, the use of heat pumps should also be expanded to this market. Due to the design of the older systems with high supply temperatures of the hydronic heating system the application of existing heat pumps is limited. The transcritical process with CO2 seems to be promising for this application. Cycle calculations considering the typical design of existing heating systems were made to obtain information about the cycle characteristics and the energetic behavior of a CO2 heat pump in such a system. The calculations were done for an air to water heat pump since this type is better suited for all-purpose installation for retrofit. It was found that a control of the high side pressure of the heat pump cycle is recommended to achieve a high COP for all seasonary conditions of the heat sink and the heat source as well as for the behavior of the volumetric heating capacity. The use of an internal heat exchanger is however not recommended since the advantages concerning COP and the behavior of the volumetric heating capacity is negligible while it leads to significantly higher discharge temperatures. Seasonal performance factors (SPF) were estimated on the basis of cycle calculations. For a heating system with design supply and return temperatures of 70C and 50C a value of 2.8 was found. In order to optimize the heat pump performance, a modification of the usual design of the heating system is proposed. The temperature difference between supply and return should be enlarged by reducing the mass flow of the water in the existing hydronic system. Calculations show that

  2. Supplementary heat requirements when brooding tom turkey poults

    African Journals Online (AJOL)

    EXPER

    naturally ventilated house with a capacity of 6500 tom turkey poults. In the calculation of heat and humidity balance, temperature values, sensible heat and moisture production of tom turkey poults were taken from the. American Society of Agricultural Engineers (ASAE) standards for corresponding turkey poult weights, and.

  3. Effect of heat treatment temperature on microstructure and ...

    Indian Academy of Sciences (India)

    Effect of heat treatment temperature on microstructure and electrochemical properties of hollow carbon spheres prepared in high-pressure argon. Boyang Liu Yun ... 40 cycles. However, the discharge capacity of the HCSs decreases and the cycling performance is improved with the increase of heat treatment temperature.

  4. DHE (downhole heat exchangers). [Downhole Heat Exchangers (DHE)

    Energy Technology Data Exchange (ETDEWEB)

    Culver, G.

    1990-11-01

    The use of downhole heat exchangers (DHE) for residential or commercial space and domestic water heating and other applications has several desirable features. Systems are nearly or completely passive -- that is, no or very little geothermal water or steam is produced from the well either reducing or completely eliminating surface environmental concerns and the need for disposal systems or injection wells. Initial cost of pumps and installation are eliminated or reduced along with pumping power costs and maintenance costs associated with pumping often corrosive geothermal fluids. Many residential and small commercial systems do not require circulating pumps because the density difference in the incoming and outgoing sides of the loop are sufficient to overcome circulating friction losses in the entire system. The major disadvantage of DHEs is their dependence on natural heat flow. In areas where geological conditions provide high permeability and a natural hydraulic gradient, DHEs can provide a substantial quantity of heat. A single 500-ft (152 m) well in Klamath Falls, Oregon, supplies over one megawatt thermal and output is apparently limited by the surface area of pipe that can be installed in the well bore. In contrast, DHEs used in conjunction with heat pumps may supply less than 8 KW from a well of similar depth. Here output is limited by conductive heat flow with perhaps a small contribution from convection near the well bore. The highest capacity DHE reported to date, in Turkey, supplies 6 MW thermal from an 820-ft (250 m) well. There were two main goals for this project. The first was to gather, disseminate and exchange internationally information on DHES. The second was to perform experiments that would provide insight into well bore/aquifer interaction and thereby provide more information on which to base DHE designs. 27 refs., 31 figs., 3 tabs.

  5. A method of determining the thermal power demand of buildings connected to the district heating system with usage of heat accumulation

    Directory of Open Access Journals (Sweden)

    Turski Michał

    2017-01-01

    Full Text Available The paper presents a new method of determining the thermal power demand of buildings connected to the district heating system, which included the actual heat demand and the possibility of balancing the thermal power using the thermal storage capacity of district heating network and internal heat capacity of buildings. Moreover, the analysis of the effect of incidence of external air temperature and duration of episodes with the lowest outdoor temperatures on the thermal power demand of district heating system was conducted.

  6. Data acquisition of space heat demand with high spatial resolution. Digital heat demand map; Erfassung des raeumlich hoch aufgeloesten Raumwaermebedarfs. Digitale Waermebedarfskarte

    Energy Technology Data Exchange (ETDEWEB)

    Blesl, Markus; Kempe, Stephan [Stuttgart Univ. (DE). Inst. fuer Energiewirtschaft und Rationelle Energieanwendung (IER); Huther, Heiko [AGFW - Der Energieeffizienzverband fuer Waerme, Kaelte und KWK e. V., Frankfurt am Main (Germany)

    2010-01-15

    For a selective and systematic expansion of the district heating capacity, detailed knowledge of the heat demand of a given town district is required. For this, a method was developed for automatic data acquisition of the space heat demand of an urban area with high spatial resolution. The method was applied exemplarily to the inner city of the town of Esslingen. (orig.)

  7. Characterization of heat dynamics of an arctic low-energy house with floor heating

    DEFF Research Database (Denmark)

    Andersen, Philip Hvidthøft Delff; Jiménez, María José; Madsen, Henrik

    2014-01-01

    the fast responses to mechanical ventilation and solar radiation through a large window facade, and the slow responses to floor heating and outdoor temperature. To successfully describe the dynamics of the system, solar radiation is given special attention in modeling of both the physical system...... and the observational noise. The estimated physical parameters which include UA-value, total heat capacity, and time constants for the apartment are discussed. Simulations are performed to illustrate step and impulse responses of inputs....

  8. Perioperative functional residual capacity.

    Science.gov (United States)

    Wahba, R W

    1991-04-01

    The literature dealing with the magnitude, mechanism and effects of reduced FRC in the perioperative period is reviewed. During general anaesthesia FRC is reduced by approximately 20%. The reduction is greater in the obese and in patients with COPD. The most likely mechanism is the loss of inspiratory muscle tone of the muscles acting on the rib cage. Gas trapping is an additional mechanism. Lung compliance decreases and airways resistance increases, in large part, due to decreased FRC. The larynx is displaced anteriorly and elongated, making laryngoscopy and intubation more difficult. The change in FRC creates or increases intrapulmonary shunt and areas of low ventilation to perfusion. This is due to the occurrence of compression atelectasis, and to regional changes in mechanics and airway closure which tend to reduce ventilation to dependent lung zones which are still well perfused. Abdominal and thoracic operations tend to increase shunting further. Large tidal volume but not PEEP will improve oxygenation, although both increase FRC. Both FRC and vital capacity are reduced following abdominal and thoracic surgery in a predictable pattern. The mechanism is the combined effect of incisional pain and reflex dysfunction of the diaphragm. Additional effects of thoracic surgery include pleural effusion, cooling of the phrenic nerve and mediastinal widening. Postoperative hypoxaemia is a function of reduced FRC and airway closure. There is no real difference among the various methods of active lung expansion in terms of the speed of restoration of lung function, or in preventing postoperative atelectasis/pneumonia. Epidural analgesia does not influence the rate of recovery of lung function, nor does it prevent atelectasis/pneumonia.

  9. Managing Capacity Through Reward Programs

    OpenAIRE

    Byung-Do Kim; Mengze Shi; Kannan Srinivasan

    2004-01-01

    Rewarding customers with own products or services has become an increasingly popular practice across a spectrum of industries such as airlines, hotels, and telecommunication. In these service industries, firms face demand uncertainty and strict short-term capacity constraint. When the market demand is low, firms hold excess capacities that would lead to intense price competition. In this paper we study the adoption and design of reward programs in the context of capacity management. We demons...

  10. Commercial high efficiency dehumidification systems using heat pipes

    Energy Technology Data Exchange (ETDEWEB)

    1993-09-01

    An improved heat pipe design using separately connected two-section one-way flow heat pipes with internal microgrooves instead of wicks is described. This design is now commercially available for use to increase the dehumidification capacity of air conditioning systems. The design also includes a method of introducing fresh air into buildings while recovering heat and controlling the humidity of the incoming air. Included are applications and case studies, load calculations and technical data, and installation, operation, and maintenance information.

  11. Oscillating heat pipes

    CERN Document Server

    Ma, Hongbin

    2015-01-01

    This book presents the fundamental fluid flow and heat transfer principles occurring in oscillating heat pipes and also provides updated developments and recent innovations in research and applications of heat pipes. Starting with fundamental presentation of heat pipes, the focus is on oscillating motions and its heat transfer enhancement in a two-phase heat transfer system. The book covers thermodynamic analysis, interfacial phenomenon, thin film evaporation,  theoretical models of oscillating motion and heat transfer of single phase and two-phase flows, primary  factors affecting oscillating motions and heat transfer,  neutron imaging study of oscillating motions in an oscillating heat pipes, and nanofluid’s effect on the heat transfer performance in oscillating heat pipes.  The importance of thermally-excited oscillating motion combined with phase change heat transfer to a wide variety of applications is emphasized. This book is an essential resource and learning tool for senior undergraduate, gradua...

  12. Heat Related Illnesses

    National Research Council Canada - National Science Library

    Carter, R; Cheuvront, S. N; Sawka, M. N

    2006-01-01

    .... The risk of serious heat illness can be markedly reduced by implementing a variety of countermeasures, including becoming acclimated to the heat, managing heat stress exposure, and maintaining hydration...

  13. Heat Roadmap Europe 1

    DEFF Research Database (Denmark)

    Connolly, David; Mathiesen, Brian Vad; Østergaard, Poul Alberg

    2012-01-01

    Heat Roadmap Europe (Pre-study 1) investigates the role of district heating in the EU27 energy system by mapping local conditions across Europe, identifying the potential for district heating expansion, and subsequently simulating the potential resource in an hourly model of the EU27 energy system....... In 2010, approximately 12% of the space heating demand in Europe is met by district heating, but in this study four alternative scenarios are considered for the EU27 energy system: 1. 2010 with 30% district heating 2. 2010 with 50% district heating 3. 2030 with 30% district heating 4. 2050 with 50......% district heating These scenarios are investigated in two steps. Firstly, district heating replaces individual boilers by converting condensing power plants to combined heat and power plants (CHP) to illustrate how district heating improves the overall efficiency of the energy system. In the second step...

  14. Multidimensional Heat Conduction

    DEFF Research Database (Denmark)

    Rode, Carsten

    1998-01-01

    Analytical theory of multidimensional heat conduction. General heat conduction equation in three dimensions. Steay state, analytical solutions. The Laplace equation. Method of separation of variables. Principle of superposition. Shape factors. Transient, multidimensional heat conduction....

  15. Heat-Related Illnesses

    Medline Plus

    Full Text Available ... sweating; nausea; and giddiness. Symptoms of heat stroke (late stage of heat illness) include flushed, hot, dry ... consciousness, vomiting or a high body temperature. For late stage heat stroke symptoms, cool the person further ...

  16. Absorption heat pump system

    Science.gov (United States)

    Grossman, Gershon

    1984-01-01

    The efficiency of an absorption heat pump system is improved by conducting liquid from a second stage evaporator thereof to an auxiliary heat exchanger positioned downstream of a primary heat exchanger in the desorber of the system.

  17. Capacity Measurement with the UIC 406 Capacity Method

    DEFF Research Database (Denmark)

    Landex, Alex; Schittenhelm, Bernd; Kaas, Anders H.

    2008-01-01

    This article describes the fast and effective UIC 406 method for calculating capacity consumption on railway lines. It is possible to expound the UIC 406 method in different ways which can lead to different capacity consumptions. Therefore, this article describes how the methodology is expounded ...

  18. Cyclic high temperature heat storage using borehole heat exchangers

    Science.gov (United States)

    Boockmeyer, Anke; Delfs, Jens-Olaf; Bauer, Sebastian

    2016-04-01

    The transition of the German energy supply towards mainly renewable energy sources like wind or solar power, termed "Energiewende", makes energy storage a requirement in order to compensate their fluctuating production and to ensure a reliable energy and power supply. One option is to store heat in the subsurface using borehole heat exchangers (BHEs). Efficiency of thermal storage is increasing with increasing temperatures, as heat at high temperatures is more easily injected and extracted than at temperatures at ambient levels. This work aims at quantifying achievable storage capacities, storage cycle times, injection and extraction rates as well as thermal and hydraulic effects induced in the subsurface for a BHE storage site in the shallow subsurface. To achieve these aims, simulation of these highly dynamic storage sites is performed. A detailed, high-resolution numerical simulation model was developed, that accounts for all BHE components in geometrical detail and incorporates the governing processes. This model was verified using high quality experimental data and is shown to achieve accurate simulation results with excellent fit to the available experimental data, but also leads to large computational times due to the large numerical meshes required for discretizing the highly transient effects. An approximate numerical model for each type of BHE (single U, double U and coaxial) that reduces the number of elements and the simulation time significantly was therefore developed for use in larger scale simulations. The approximate numerical model still includes all BHE components and represents the temporal and spatial temperature distribution with a deviation of less than 2% from the fully discretized model. Simulation times are reduced by a factor of ~10 for single U-tube BHEs, ~20 for double U-tube BHEs and ~150 for coaxial BHEs. This model is then used to investigate achievable storage capacity, injection and extraction rates as well as induced effects for

  19. Regenerative adsorbent heat pump

    Science.gov (United States)

    Jones, Jack A. (Inventor)

    1991-01-01

    A regenerative adsorbent heat pump process and system is provided which can regenerate a high percentage of the sensible heat of the system and at least a portion of the heat of adsorption. A series of at least four compressors containing an adsorbent is provided. A large amount of heat is transferred from compressor to compressor so that heat is regenerated. The process and system are useful for air conditioning rooms, providing room heat in the winter or for hot water heating throughout the year, and, in general, for pumping heat from a lower temperature to a higher temperature.

  20. Study on Surface Heat Budget of Various Pavements for Urban Heat Island Mitigation

    Directory of Open Access Journals (Sweden)

    Hideki Takebayashi

    2012-01-01

    Full Text Available The surface heat budgets of various pavement surfaces are studied with the aim of mitigating the urban heat island effect. In this study, the thermal characteristics of pavements are examined using data from observations. The net radiation, surface temperature, temperature under the surface, conduction heat flux, and core weight for each experimental surface are recorded, together with the weather conditions at the time of observation. The latent heat flux is estimated from the observed weight of the cores. The surface heat budget under the same weather conditions is examined, and the sensible heat flux from each target surface is calculated. The parameters that influence the surface heat budget, for example, solar reflectance (albedo, evaporative efficiency, heat conductivity, and heat capacity, are examined. On a typical summer day, the maximum reduction in the sensible heat flux from that on a normal asphalt surface is about 150 W/m2 for an asphalt surface with water-retaining material and about 100 W/m2 for a cement concrete surface with water-retaining material, depending on the albedo of each surface.

  1. Improved district heating substation efficiency with a new control strategy

    Energy Technology Data Exchange (ETDEWEB)

    Gustafsson, Jonas; Delsing, Jerker; van Deventer, Jan [Div. of EISLAB, Dept. of Computer Science and Electrical Engineering, Luleaa University of Technology, 97187 Luleaa (Sweden)

    2010-06-15

    In this paper, we describe a new alternative control approach for indirectly connected district heating substations. Simulations results showed that the new approach results in an increased {delta} T across the substation. Results were obtained for both ideal and non-ideal operation of the system, meaning that less water must be pumped through the district heating network, and a higher overall fuel efficiency can be obtained in the district heating power plants. When a higher fuel efficiency is achieved, the usage of primary fuel sources can be reduced. Improved efficiency also increases the effective heat transfer capacity of a district heating network, allowing more customers to be connected to an existing network without increasing the heating plant or network capacity. Also, if combined heat and power plants are used to produce the heat, the increased {delta} T will result in a further improved overall fuel efficiency, as more electricity can be produced with colder cooling water. The idea behind the new control method is to consider the temperature of the water supplying the district heating substation with heat, often referred to as the primary supply temperature. This represents a logical next step, as currently, the only parameter generally taken into account or measured when controlling the temperature level of the radiator circuit is the local outdoor temperature. In this paper we show how the primary supply temperature together with thermodynamic knowledge of the building can be used to maximize the {delta} T across the district heating substation. (author)

  2. Flexible use of electricity in heat-only district heating plants

    Directory of Open Access Journals (Sweden)

    Erik Trømborg

    2017-01-01

    Full Text Available European energy systems are in a period of significant transition, with the increasing shares of variable renewable energy (VRE and less flexible fossil-based generation units as predominant factors. The supply-side changes are expected to cause large short-term electricity price volatility. More frequent periods of low electricity prices may mean that electric use in flexible heating systems will become more profitable, and such flexible heating systems may, in turn, improve the integration of increasing shares of VRE. The objective of this study is to analyze the likely future of Nordic electricity price levels and variations and how the expected prices might affect the use of electricity and thermal storage in heat-only district heating plants. We apply the North European energy market model Balmorel to provide scenarios for future hourly electricity prices in years with normal, high, and low inflow levels to the hydro power system. The simulation tool energyPRO is subsequently applied to quantify how these electricity price scenarios affect the hourly use of thermal storage and individual boilers in heat-only district heating plants located in Norway. The two studied example plants use wood chips or heat pump as base load representing common technologies for district heating in Norway. The Balmorel results show that annual differences in inflow is still a decisive factor for Norwegian and Nordic electricity prices in year 2030 and that short-term (daily price variability is expected to increase. In the plant-level simulations, we find that tank storage, which is currently installed in only a few district heating plants in Norway, is a profitable flexibility option that will significantly reduce the use of fossil peak load in both biomass and heat-pump-based systems. Installation of an electric boiler in addition to tank storage is profitable in the heat pump system due to the limited capacity of the heat pump. Electricity will hence, to a

  3. Numerical and Experimental Investigation for Heat Transfer Enhancement by Dimpled Surface Heat Exchanger in Thermoelectric Generator

    Science.gov (United States)

    Wang, Yiping; Li, Shuai; Yang, Xue; Deng, Yadong; Su, Chuqi

    2016-03-01

    For vehicle thermoelectric exhaust energy recovery, the temperature difference between the heat exchanger and the coolant has a strong influence on the electric power generation, and ribs are often employed to enhance the heat transfer of the heat exchanger. However, the introduction of ribs will result in a large unwanted pressure drop in the exhaust system which is unfavorable for the engine's efficiency. Therefore, how to enhance the heat transfer and control the pressure drop in the exhaust system is quite important for thermoelectric generators (TEG). In the current study, a symmetrical arrangement of dimpled surfaces staggered in the upper and lower surfaces of the heat exchanger was proposed to augment heat transfer rates with minimal pressure drop penalties. The turbulent flow characteristics and heat transfer performance of turbulent flow over the dimpled surface in a flat heat exchanger was investigated by numerical simulation and temperature measurements. The heat transfer capacity in terms of Nusselt number and the pressure loss in terms of Fanning friction factors of the exchanger were compared with those of the flat plate. The pressure loss and heat transfer characteristics of dimples with a depth-to-diameter ratio ( h/D) at 0.2 were investigated. Finally, a quite good heat transfer performance with minimal pressure drop heat exchanger in a vehicle TEG was obtained. And based on the area-averaged surface temperature of the heat exchanger and the Seeback effect, the power generation can be improved by about 15% at Re = 25,000 compared to a heat exchanger with a flat surface.

  4. Initial characterization of a modular heat exchanger with an integral heat pipe

    Science.gov (United States)

    Schreiber, Jeffrey G.

    1989-01-01

    As part of the Civil Space Technology Initiative (CSTI) Advanced Technology program, a conceptual design of the Stirling space engine (SSE) was generated. The overall goal of the CSTI high capacity power element is to develop the technology base needed to meet the long duration, high capacity power requirements for future NASA space missions. The free-piston Stirling engine (FPSE) was chosen as the growth option in the CSTI program. A major goal during the conceptual design of the SSE was to reduce the number of critical joints. One area of concern was the heat exchanger assemblies that typically have the majority of critical joints. The solution proposed in the SSE conceptual design used 40 modular heat exchangers. Each module has its own integral heat pipe to transport heat from the heat source to the engine. A demonstration of the modular concept was undertaken before committing to the detailed design of the SSE heat exchangers. An existing FPSE was modified as a test bed for modular heat exchanger evaluation. The engine incorporated three heat exchanger modules, each having a sodium filled heat pipe. The thermal loading of these modules was intended to be similar to the conditions projected for the SSE modules. The engine was assembled and tests are underway. The design and fabrication of the heat exchanger modules and the engine used for these tests were described. Evaluation of the individual heat pipes before installation in the engine is described. The initial test results with the modules in operation on the engine were presented. Future tests involving the engine were outlined.

  5. Strategic Capacity Investment Under uncertainty

    NARCIS (Netherlands)

    Huisman, K.J.M.; Kort, P.M.

    2013-01-01

    Abstract: This paper considers investment decisions within an uncertain dynamic and competitive framework. Each investment decision involves to determine the timing and the capacity level. In this way we extend the main bulk of the real options theory where the capacity level is given. We consider a

  6. Fiscal Capacity Equalisation in Tanzania

    NARCIS (Netherlands)

    Allers, Maarten A.; Ishemoi, Lewis J.

    2010-01-01

    Fiscal equalisation aims at enabling decentralised governments to supply similar services at similar tax rates. In order to equalise fiscal disparities, differences in both fiscal capacities and in fiscal needs have to be measured. This paper focuses on the measurement of fiscal capacity in a

  7. Contemporaneous assessment of testamentary capacity.

    Science.gov (United States)

    Shulman, Kenneth I; Peisah, Carmelle; Jacoby, Robin; Heinik, Jeremia; Finkel, Sanford

    2009-06-01

    Challenges to wills on the basis of lack of testamentary capacity and/or undue influence are likely to increase over the next generation. Since contemporaneous assessment of testamentary capacity can be a powerful influence on the outcome of such challenges, there will be an associated increase in requests for expert assessment of testamentary capacity. There is a need to provide such potential experts with the knowledge and guidelines necessary to conduct assessments that will be helpful to the judicial system. A subcommittee of the International Psychogeriatric Association (IPA) task force on "Testamentary Capacity and Undue Influence" was formed to establish guidelines for contemporaneous assessment of testamentary capacity. The task-specific criteria for testamentary capacity as outlined by Lord Chief Justice Cockburn in the well-known Banks v. Goodfellow case are described. Additional issues are identified for probing and documentation. This is designed to determine whether the testator can formulate a coherent, rational testamentary plan that connects his/her beliefs, values and relationships with the proposed disposition of assets. Rules of engagement by the expert assessor are defined as well as an approach to the clinical examination for testamentary capacity resulting in a clear and relevant report. Guidelines for experts who are asked to provide a contemporaneous opinion on testamentary capacity should help to inform disputes resulting from challenges to wills. A consistent clinical approach will help the courts to make their determinations.

  8. Concrete Operations and Attentional Capacity.

    Science.gov (United States)

    Chapman, Michael; Lindenberger, Ulman

    1989-01-01

    To test predictions regarding the attentional capacity requirements of Piaget's stage of concrete operations, a battery of concrete operational tasks and two measures of attentional capacity were administered to 120 first-, second-, and third-graders. Findings concern class inclusion, transitivity of length and weight, and multiplication of…

  9. Endoscopic capacity in West Africa.

    African Journals Online (AJOL)

    Abstract: Background: Levels of endoscopic demand and capacity in West Africa are unclear. Objectives: This paper aims to: 1. describe the current labor and endoscopic capacity, 2. quantify the impact of a mixed-meth- ods endoscopy course on healthcare professionals in West Africa, and 3. quantify the types of diagnoses ...

  10. Improving African health research capacity

    DEFF Research Database (Denmark)

    Lazarus, Jeff; Wallace, Samantha A; Liljestrand, Jerker

    2010-01-01

    The issue of strengthening local research capacity in Africa is again high on the health and development agenda. The latest initiative comes from the Wellcome Trust. But when it comes to capacity development, one of the chief obstacles that health sectors in the region must confront is the migrat...

  11. Checking Capacity for MIMO Configurations

    DEFF Research Database (Denmark)

    Thaysen, Jesper; Jakobsen, Kaj Bjarne

    2007-01-01

    Wireless system capacity can be added by increasing the number of antennas in a MIMO setup or by carefully optimizing the performance of a smaller number of antennas.......Wireless system capacity can be added by increasing the number of antennas in a MIMO setup or by carefully optimizing the performance of a smaller number of antennas....

  12. Capacity Building in Land Administration

    DEFF Research Database (Denmark)

    Enemark, Stig; Williamson, I

    2004-01-01

    Capacity building increasingly seen as a key component of land administration projects in developing and countries in transition undertaken by the international development banks and individual country development assistance agencies. However, the capacity building concept is often used within...... infrastructures for implementing land policies in a sustainable way. Where a project is established to create land administration infrastructures in developing or transition countries, it is critical that capacity building is a mainstream component, not as an add-on, which is often the case. In fact such projects...... should be dealt with as capacity building projects in themselves.    The article introduces a conceptual analytical framework that provides some guidance when dealing with capacity building for land administration in support of a broader land policy agenda....

  13. Evaluating the Cost of Line Capacity Limitations in Aggregations of Commercial Buildings

    DEFF Research Database (Denmark)

    Ziras, Charalampos; Delikaraoglou, Stefanos; Kazempour, Jalal

    2017-01-01

    The trend towards electrification of the heating sector in many cases leads to the replacement of fossil-fueled heating systems with electric heat pumps. This may result to significantly higher consumption and potentially violations of the distribution grid operational limits. We propose a day......-ahead optimization strategy to assess the cost of imposing capacity limitations in the total consumption of individual buildings, as well as aggregations of buildings. We show that such capacity limitations lead to an increase for the buildings operational costs, which can be interpreted as the value...... of these limitations. Based on such calculations, the aggregator can value capacity-limitation services to the distribution system operator. Moreover, the value of aggregation is also highlighted, since it leads to lower costs than imposing the same total capacity limitation on individual buildings....

  14. Monogroove heat pipe development for the space constructible radiator system

    Science.gov (United States)

    Alario, J.; Brown, R.; Kosson, R.

    1983-06-01

    A high-capacity, high-reliability space radiator is needed in order to satisfy the future heat rejection requirements of large space platforms or space stations. The Space Constructible Radiator (SCR) system is being developed to fill this need. The most important component of the SCR system is the high-capacity monogroove heat pipe which theoretically has a heat transport capacity of 12,700 W-m to 25,400 W-m. This performance represents a better than two order of magnitude increase in transport capacity over currently existing heat pipes. The present investigation is concerned with testing developments which occurred in connection with the monogroove heat pipe during the last two years. A short description of the SCR system is presented, and results are provided for two series of tests which were run on a 15.7-m long heat pipe. The first test series included both performance and diagnostic tests, which pointed to some design modifications which were necessary. The second test series, run on the modified heat pipe, showed improved performance.

  15. Entropy Change for the Irreversible Heat Transfer between Two Finite Objects

    Science.gov (United States)

    2015-06-10

    Letters and Comments Entropy change for the irreversible heat transfer between two finite objects Carl E Mungan Physics Department, US Naval Academy...June 2015 Abstract A positive entropy change is verified for an isolated system of two blocks of different initial temperatures and of different but...finite heat capacities that are brought into contact with each other and allowed to fully thermalize. Keywords: thermalization, entropy , heat capacity

  16. Theoretical energy and exergy analyses of solar assisted heat pump space heating system

    Directory of Open Access Journals (Sweden)

    Atmaca Ibrahim

    2014-01-01

    Full Text Available Due to use of alternative energy sources and energy efficient operation, heat pumps come into prominence in recent years. Especially in solar-assisted heat pumps, sizing the required system is difficult and arduous task in order to provide optimum working conditions. Therefore, in this study solar assisted indirect expanded heat pump space heating system is simulated and the results of the simulation are compared with available experimental data in the literature in order to present reliability of the model. Solar radiation values in the selected region are estimated with the simulation. The case study is applied and simulation results are given for Antalya, Turkey. Collector type and storage tank capacity effects on the consumed power of the compressor, COP of the heat pump and the overall system are estimated with the simulation, depending on the radiation data, collector surface area and the heating capacity of the space. Exergy analysis is also performed with the simulation and irreversibility, improvement potentials and exergy efficiencies of the heat pump and system components are estimated.

  17. The air-conditioning capacity of the human nose.

    Science.gov (United States)

    Naftali, Sara; Rosenfeld, Moshe; Wolf, Michael; Elad, David

    2005-04-01

    The nose is the front line defender of the respiratory system. Unsteady simulations in three-dimensional models have been developed to study transport patterns in the human nose and its overall air-conditioning capacity. The results suggested that the healthy nose can efficiently provide about 90% of the heat and the water fluxes required to condition the ambient inspired air to near alveolar conditions in a variety of environmental conditions and independent of variations in internal structural components. The anatomical replica of the human nose showed the best performance and was able to provide 92% of the heating and 96% of the moisture needed to condition the inspired air to alveolar conditions. A detailed analysis explored the relative contribution of endonasal structural components to the air-conditioning process. During a moderate breathing effort, about 11% reduction in the efficacy of nasal air-conditioning capacity was observed.

  18. Ground Source Heat Pump Sub-Slab Heat Exchange Loop Performance in a Cold Climate

    Energy Technology Data Exchange (ETDEWEB)

    Mittereder, Nick [IBACOS, Inc., Pittsburgh, PA (United States); Poerschke, Andrew [IBACOS, Inc., Pittsburgh, PA (United States)

    2013-11-01

    This report presents a cold-climate project that examines an alternative approach to ground source heat pump (GSHP) ground loop design. The innovative ground loop design is an attempt to reduce the installed cost of the ground loop heat exchange portion of the system by containing the entire ground loop within the excavated location beneath the basement slab. Prior to the installation and operation of the sub-slab heat exchanger, energy modeling using TRNSYS software and concurrent design efforts were performed to determine the size and orientation of the system. One key parameter in the design is the installation of the GSHP in a low-load home, which considerably reduces the needed capacity of the ground loop heat exchanger. This report analyzes data from two cooling seasons and one heating season.

  19. The usage of waste heat recovery units with improved heat engineering rates: theory and experimental research

    Science.gov (United States)

    Chebotarev, Victor; Koroleva, Alla; Pirozhnikova, Anastasia

    2017-10-01

    Use of recuperator in heat producing plants for utilization of natural gas combustion products allows to achieve the saving of gas fuel and also provides for environmental sanitation. Decrease of the volumes of natural gas combustion due to utilization of heat provides not only for reduction of harmful agents in the combustion products discharged into the atmosphere, but also creates conditions for increase of energy saving in heating processes of heat producing plants due to air overheating in the recuperator. Grapho-analytical method of determination of energy saving and reduction of discharges of combustion products into the atmosphere is represented in the article. Multifunctional diagram is developed, allowing to determine simultaneously savings from reduction of volumes of natural gas combusted and from reduction of amounts of harmful agents in the combustion products discharged into the atmosphere. Calculation of natural gas economy for heat producing plant taking into consideration certain capacity is carried out.

  20. Nature's Heat Exchangers.

    Science.gov (United States)

    Barnes, George

    1991-01-01

    Discusses the heat-transfer systems of different animals. Systems include heat conduction into the ground, heat transferred by convection, heat exchange in lizards, fish and polar animals, the carotid rete system, electromagnetic radiation from animals and people, and plant and animal fiber optics. (MDH)

  1. Transient Heat Conduction

    DEFF Research Database (Denmark)

    Rode, Carsten

    1998-01-01

    Analytical theory of transient heat conduction.Fourier's law. General heat conducation equation. Thermal diffusivity. Biot and Fourier numbers. Lumped analysis and time constant. Semi-infinite body: fixed surface temperature, convective heat transfer at the surface, or constant surface heat flux...

  2. Solar Heating Equipment

    Science.gov (United States)

    1981-01-01

    Solar Unlimited, Inc.'s suncatcher line includes a variety of solar arrays, derived from NASA's satellite program: water heating only, partial home heating, or water and whole house central heating. Solar Unlimited developed a set of vigorous requirements to avoid problems common to solar heating technologies.

  3. Rotary magnetic heat pump

    Science.gov (United States)

    Kirol, Lance D.

    1988-01-01

    A rotary magnetic heat pump constructed without flow seals or segmented rotor accomplishes recuperation and regeneration by using split flow paths. Heat exchange fluid pumped through heat exchangers and returned to the heat pump splits into two flow components: one flowing counter to the rotor rotation and one flowing with the rotation.

  4. On heat properties of AdS black holes in higher dimensions

    Energy Technology Data Exchange (ETDEWEB)

    Belhaj, A. [Département de Physique, Faculté Polydisciplinaire, Université Sultan M. Slimane,Béni Mellal (Morocco); High Energy Physics and Astrophysics Laboratory, FSSM, Cadi Ayyad University,Marrakesh (Morocco); Chabab, M.; Moumni, H. El; Masmar, K. [High Energy Physics and Astrophysics Laboratory, FSSM, Cadi Ayyad University,Marrakesh (Morocco); Sedra, M.B. [Université Mohammed Premier, Ecole Nationale des Sciences Appliquées,Al Hoceima (Morocco); Département de Physique, LHESIR, Faculté des Sciences, Université Ibn Tofail,Kénitra (Morocco); Segui, A. [Departamento de Física Teórica, Universidad de Zaragoza,E-50009-Zaragoza (Spain)

    2015-05-28

    We investigate the heat properties of AdS Black Holes in higher dimensions. We consider the study of the corresponding thermodynamical properties including the heat capacity explored in the determination of the black hole stability. In particular, we compute the heat latent. To overcome the instability problem, the Maxwell construction, in the (T,S)-plane, is elaborated. This method is used to modify the the Hawking-Page phase structure by removing the negative heat capacity regions. Then, we discuss the thermodynamic cycle and the heat engines using the way based on the extraction of the work from a black hole solution.

  5. Heat pump air conditioning system for pure electric vehicle at ultra-low temperature

    Directory of Open Access Journals (Sweden)

    Li Hai-Jun

    2014-01-01

    Full Text Available When the ordinary heat pump air conditioning system of a pure electric vehicle runs at ultra-low temperature, the discharge temperature of compressor will be too high and the heating capacity of the system will decay seriously, it will lead to inactivity of the heating system. In order to solve this problem, a modification is put forward, and an experiment is also designed. The experimental results show that in the same conditions, this new heating system increases more than 20% of the heating capacity; when the outside environment temperature is negative 20 degrees, the discharge temperature of compressor is below 60 degrees.

  6. Interference and memory capacity limitations.

    Science.gov (United States)

    Endress, Ansgar D; Szabó, Szilárd

    2017-10-01

    Working memory (WM) is thought to have a fixed and limited capacity. However, the origins of these capacity limitations are debated, and generally attributed to active, attentional processes. Here, we show that the existence of interference among items in memory mathematically guarantees fixed and limited capacity limits under very general conditions, irrespective of any processing assumptions. Assuming that interference (a) increases with the number of interfering items and (b) brings memory performance to chance levels for large numbers of interfering items, capacity limits are a simple function of the relative influence of memorization and interference. In contrast, we show that time-based memory limitations do not lead to fixed memory capacity limitations that are independent of the timing properties of an experiment. We show that interference can mimic both slot-like and continuous resource-like memory limitations, suggesting that these types of memory performance might not be as different as commonly believed. We speculate that slot-like WM limitations might arise from crowding-like phenomena in memory when participants have to retrieve items. Further, based on earlier research on parallel attention and enumeration, we suggest that crowding-like phenomena might be a common reason for the 3 major cognitive capacity limitations. As suggested by Miller (1956) and Cowan (2001), these capacity limitations might arise because of a common reason, even though they likely rely on distinct processes. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  7. MODELLING OF HEAT CONDUCTIVITY OF COMPOSITE MATERIALS WITH BALL INCLUSIONS

    Directory of Open Access Journals (Sweden)

    V. Pugachev Oleg

    2017-01-01

    Full Text Available A number of papers deals with the heat conductivity of composite materials: Zarubin et al used new approaches to the problem of evaluation of the effective heat conductivity coefficients of composite material with ball inclusions. We used variational analysis for a simplified model in a vicinity of inclusion. Contemporary computers allow implementing another approach to solving the problem of the effective heat conductivity: it may be modelled by the Brownian motion of virtual heat particles. The main idea is to obtain the exact formula for the heat conductivity for a homogeneous material and subsequently obtain a statistical evaluation of this formula for a composite material.In the present paper we compare two methods for finding the effective heat conductivity coefficients of composite materials by modeling the process of heat conduction via the Brownian motion of virtual heat particles. We consider a composite with ball inclusions of a material with heat conductivity and heat capacity coefficientsdiffering from those of the matrix material. In a computational experiment, we simulate the process of heatconduction through a flat layer of the composite material, which has been heated on one side at the initial moment. In order to find the confidence interval for the effective heat conductivity coefficient, we find, by means of statistics, either the displacement of the center of heat energy, or the probability of a virtual particle to pass through the layer during a certain time. We compare our results with theoretical assessments suggested by other authors.

  8. Heat Roadmap Europe

    DEFF Research Database (Denmark)

    Hansen, Kenneth; Connolly, David; Lund, Henrik

    2015-01-01

    of supplying sustainable heating. Different heat production options are included in terms of individual and community heating systems. Furthermore, the levelised cost of supplying sustainable heat is estimated for both a single technology and from an energy system perspective. The results are analysed...... by assessing various parameters such as socio-economic costs and energy efficiency improvements in the national energy systems. The results demonstrate the economically feasible levels of heat savings and heat production for various European countries, highlighting differences in their national conditions......The cost of heat savings in buildings increase as more heat savings are achieved due to the state of the building stock and hence, alternatives other than savings typically become more economically feasible at a certain level of heat reductions. It is important to identify when the cost of heat...

  9. Heat Roadmap Europe 2

    DEFF Research Database (Denmark)

    Connolly, David; Mathiesen, Brian Vad; Østergaard, Poul Alberg

    Many strategies have already been proposed for the decarbonisation of the EU energy system by the year 2050. These typically focus on the expansion of renewable energy in the electricity sector and subsequently, electrifying both the heat and transport sectors as much as possible...... are identified and then, the EU27 energy system is modelled to investigate the impact of district heating. The results indicate that a combination of heat savings, district heating in urban areas, and individual heat pumps in rural areas will enable the EU27 to reach its greenhouse gas emission targets by 2050....... In these strategies, the role of district heating has never been fully explored system, nor have the benefits of district heating been quantified at the EU level. This study combines the mapping of local heat demands and local heat supplies across the EU27. Using this local knowledge, new district heating potentials...

  10. Heat Roadmap Europe

    DEFF Research Database (Denmark)

    Connolly, David; Mathiesen, Brian Vad; Lund, Henrik

    2015-01-01

    information systems (GIS) and energy system analyses. In this report, the inputs for other modelling tools such as PRIMES are presented, in order to enable other researches to generate similar heating scenarios for Europe. Although Heat Roadmap Europe presents a complete heat strategy for Europe, which...... includes energy efficiency, individual heating units (such as boilers and heat pumps), and heat networks, the recommendations here are primarily relating to the potential and modelling of district heating. Although other solutions will play a significant role in decarbonising the heating and cooling sector...... in a low-carbon energy system context, so we have focused on this area based on our extensive experience in this area [1-10]. This report includes guidelines on the potential heat demand in European buildings that can be met by district heating as well as some general guidelines on how this district...

  11. Compressed air energy storage with liquid air capacity extension

    OpenAIRE

    Kantharaj, Bharath; Garvey, Seamus D.; Pimm, Andrew James

    2015-01-01

    As renewable electricity generation capacity increases, energy storage will be required at larger scales. Compressed Air Energy Storage (CAES) at large scales, with effective management of heat, is recognised to have potential to provide affordable grid-scale energy storage. Where suitable geologies are unavailable, compressed air could be stored in pressurised steel tanks above ground, but this would incur significant storage costs. Liquid Air Energy Storage (LAES), on the other hand, does n...

  12. The share flight experiment - An advanced heat pipe radiator for Space Station

    Science.gov (United States)

    Alario, J. P.; Otterstedt, P. J.

    1986-01-01

    This paper reports on the design and thermal vacuum certification testing of the Space Station Heat Pipe Advanced Radiator Element (SHARE) Shuttle flight experiment, with primary emphasis on the heat pipe radiator system. The main objective of the SHARE experiment is to demonstrate suitable 0 g heat transfer performance of a 50 ft-long high-capacity monogroove heat pipe radiator element being developed for possible Space Station application. All of the flight certification tests were achieved, including a maximum heat rejection of 2 kW and thawing of a frozen heat pipe; and uninterrupted operation under cycling environmental and evaporator heat loads.

  13. Large capacity temporary visual memory

    Science.gov (United States)

    Endress, Ansgar D.; Potter, Mary C.

    2014-01-01

    Visual working memory (WM) capacity is thought to be limited to three or four items. However, many cognitive activities seem to require larger temporary memory stores. Here, we provide evidence for a temporary memory store with much larger capacity than past WM capacity estimates. Further, based on previous WM research, we show that a single factor — proactive interference — is sufficient to bring capacity estimates down to the range of previous WM capacity estimates. Participants saw a rapid serial visual presentation (RSVP) of 5 to 21 pictures of familiar objects or words presented at rates of 4/s or 8/s, respectively, and thus too fast for strategies such as rehearsal. Recognition memory was tested with a single probe item. When new items were used on all trials, no fixed memory capacities were observed, with estimates of up to 9.1 retained pictures for 21-item lists, and up to 30.0 retained pictures for 100-item lists, and no clear upper bound to how many items could be retained. Further, memory items were not stored in a temporally stable form of memory, but decayed almost completely after a few minutes. In contrast, when, as in most WM experiments, a small set of items was reused across all trials, thus creating proactive interference among items, capacity remained in the range reported in previous WM experiments. These results show that humans have a large-capacity temporary memory store in the absence of proactive interference, and raise the question of whether temporary memory in everyday cognitive processing is severely limited as in WM experiments, or has the much larger capacity found in the present experiments. PMID:23937181

  14. An investigation of the storage capability of district heating networks. Consequences of heat production; Untersuchung der Speicherfaehigkeit von Fernwaermenetzen. Auswirkungen auf die Waermeerzeugung

    Energy Technology Data Exchange (ETDEWEB)

    Gross, Sebastian; Felsmann, Clemens [Technische Univ. Dresden (Germany). Professur fuer Gebaeudeenergietechnik und Waermeversorgung

    2012-01-15

    The storage of energy is a key issue in terms of the energy policy turnaround and the concomitant increase in decentralized power generation. District heating networks can be used as a heat storage. But is this reasonable energetically and economically? And what is the situation with the storage capacity of district heating networks? How does this storage capability impact on the use of heat sources? The authors of the contribution under consideration try to give an answer to these questions.

  15. Heat Transfer Analysis of Fin Tube

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Woo-Jin [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Choi, Cheng-Ryul [ELSOLTEC Co., Yongin (Korea, Republic of)

    2015-10-15

    This paper describes a preliminary numerical analysis of fin tube used for a heat exchanger of the air-water cooling system. The internal flow in a fin tube is steam and the external of the fin is cooled by air. Cooling system in a nuclear power plant can be divided into two categories; 1) active pump driven system powered by alternating current and 2) passive cooling system drived by natural circulation phenomena. After the accident in Hukushima Nuclear Power Plants, the importance of the passive cooling system that can provide a long-term cooling of reactor decay heat during station blackout condition is emphasized. However, the effectiveness of passive cooling system based on cooling water is limited by the capacity of water storage tank. To overcome the limit due to the exhaustion of the cooling water, an natural convection air cooling system is proposed. As the air operated cooling system utilizes natural circulation phenomena of air, it does not require cooling water. However, the heat transfer area of the air operated cooling system should be increased much as the heat removal capacity per unit area is much lower than that of water cooling system. The air-water combined cooling system can resolve this excess increase of the heat transfer area in the air operated cooling system. This air-water cooling system can be also used in the passive containment cooling system. The effect of design parameters such as fin tube arrangement, the fin height, and pitch has been analyzed and the chimney effect on the simulation of heat transfer in a heat exchanger is evaluated. The internal flows in a fin tube heat exchanger for natural circulation flow condition and forced convection (suction) condition were investigated.

  16. Regular capacities on metrizable spaces

    Directory of Open Access Journals (Sweden)

    T. M. Cherkovskyi

    2014-07-01

    Full Text Available It is proved that for a (not necessarily compact metric space: the metrics on the space of capacities in the sense of Zarichnyi and Prokhorov are equal; completeness of the space of capacities is equivalent to completeness of the original space. It is shown that for the capacities on metrizable spaces the properties of $\\omega$-smoothness and of $\\tau$-smoothness are equivalent precisely on the separable spaces, and the properties of $\\omega$-smoothness and of regularity w.r.t. some (then w.r.t. any admissible metric are equivalent precisely on the compact spaces.

  17. Introduction to heat transfer

    CERN Document Server

    SUNDÉN, B

    2012-01-01

    Presenting the basic mechanisms for transfer of heat, Introduction to Heat Transfer gives a deeper and more comprehensive view than existing titles on the subject. Derivation and presentation of analytical and empirical methods are provided for calculation of heat transfer rates and temperature fields as well as pressure drop. The book covers thermal conduction, forced and natural laminar and turbulent convective heat transfer, thermal radiation including participating media, condensation, evaporation and heat exchangers.

  18. Ground Source Heat Pump Sub-Slab Heat Exchange Loop Performance in a Cold Climate

    Energy Technology Data Exchange (ETDEWEB)

    Mittereder, N.; Poerschke, A.

    2013-11-01

    This report presents a cold-climate project that examines an alternative approach to ground source heat pump (GSHP) ground loop design. The innovative ground loop design is an attempt to reduce the installed cost of the ground loop heat exchange portion of the system by containing the entire ground loop within the excavated location beneath the basement slab. Prior to the installation and operation of the sub-slab heat exchanger, energy modeling using TRNSYS software and concurrent design efforts were performed to determine the size and orientation of the system. One key parameter in the design is the installation of the GSHP in a low-load home, which considerably reduces the needed capacity of the ground loop heat exchanger. This report analyzes data from two cooling seasons and one heating season. Upon completion of the monitoring phase, measurements revealed that the initial TRNSYS simulated horizontal sub-slab ground loop heat exchanger fluid temperatures and heat transfer rates differed from the measured values. To determine the cause of this discrepancy, an updated model was developed utilizing a new TRNSYS subroutine for simulating sub-slab heat exchangers. Measurements of fluid temperature, soil temperature, and heat transfer were used to validate the updated model.

  19. Heat cascading regenerative sorption heat pump

    Science.gov (United States)

    Jones, Jack A. (Inventor)

    1995-01-01

    A simple heat cascading regenerative sorption heat pump process with rejected or waste heat from a higher temperature chemisorption circuit (HTCC) powering a lower temperature physisorption circuit (LTPC) which provides a 30% total improvement over simple regenerative physisorption compression heat pumps when ammonia is both the chemisorbate and physisorbate, and a total improvement of 50% or more for LTPC having two pressure stages. The HTCC contains ammonia and a chemisorbent therefor contained in a plurality of canisters, a condenser-evaporator-radiator system, and a heater, operatively connected together. The LTPC contains ammonia and a physisorbent therefor contained in a plurality of compressors, a condenser-evaporator-radiator system, operatively connected together. A closed heat transfer circuit (CHTC) is provided which contains a flowing heat transfer liquid (FHTL) in thermal communication with each canister and each compressor for cascading heat from the HTCC to the LTPC. Heat is regenerated within the LTPC by transferring heat from one compressor to another. In one embodiment the regeneration is performed by another CHTC containing another FHTL in thermal communication with each compressor. In another embodiment the HTCC powers a lower temperature ammonia water absorption circuit (LTAWAC) which contains a generator-absorber system containing the absorbent, and a condenser-evaporator-radiator system, operatively connected together. The absorbent is water or an absorbent aqueous solution. A CHTC is provided which contains a FHTL in thermal communication with the generator for cascading heat from the HTCC to the LTAWAC. Heat is regenerated within the LTAWAC by transferring heat from the generator to the absorber. The chemical composition of the chemisorbent is different than the chemical composition of the physisorbent, and the absorbent. The chemical composition of the FHTL is different than the chemisorbent, the physisorbent, the absorbent, and ammonia.

  20. Heat transfer to the adsorbent in solar adsorption cooling device

    Science.gov (United States)

    Pilat, Peter; Patsch, Marek; Papucik, Stefan; Vantuch, Martin

    2014-08-01

    The article deals with design and construction of solar adsorption cooling device and with heat transfer problem in adsorber. The most important part of adsorption cooling system is adsorber/desorber containing adsorbent. Zeolith (adsorbent) type was chosen for its high adsorption capacity, like a coolant was used water. In adsorber/desorber occur, at heating of adsorbent, to heat transfer from heat change medium to the adsorbent. The time required for heating of adsorber filling is very important, because on it depend flexibility of cooling system. Zeolith has a large thermal resistance, therefore it had to be adapted the design and construction of adsorber. As the best shows the tube type of adsorber with double coat construction. By this construction is ensured thin layer of adsorbent and heating is quick in all volume of adsorbent. The process of heat transfer was experimentally measured, but for comparison simulated in ANSYS, too.

  1. Heat stroke and related heat stress disorders.

    Science.gov (United States)

    Knochel, J P

    1989-05-01

    Medical disorders related to environmental heat exposure are exceptionally common in persons who perform hard work in hot climates. They are also common in competitive athletes as well as in persons who participate in casual exercise to maintain health. The important issue of salt and water disturbances consequent to heavy sweating in hot climates is discussed in detail as are mechanisms of potassium deficiency and its implications. The major forms of environmental heat illness including heat syncope, heat cramp, heat exhaustion, and heat stroke are presented in detail with relevant clinical examples. A discussion of the differential diagnosis of hyperthermia and rhabdomyolysis follows. Because of the difference in treatment and complications, heat stroke is subdivided into the classic variety that affects the elderly and very young and that form that follows heavy physical work and is always associated with rhabdomyolysis. Because severe heat exhaustion and heat stroke are life-threatening disorders, the chapter includes a detailed discussion of complications and plans for treatment.

  2. Research projects and capacity building

    African Journals Online (AJOL)

    driniev

    2004-10-04

    Oct 4, 2004 ... bility of promoting research and developing research capacity. In an effort to include .... responsibilities so as to jointly create the learning environment and enabling conditions in ..... a Learning Organization. London: Nicholas ...

  3. Entrepreneurship Education and Entrepreneurship Capacity ...

    African Journals Online (AJOL)

    Entrepreneurship Education and Entrepreneurship Capacity Development from the Perspective of a Nigerian University. ... KCA Journal of Business Management ... The study therefore recommends that the Nigerian Universities Commission (NUC) should review the national tertiary educational and related policies to ...

  4. Capacity Building in Land Management

    DEFF Research Database (Denmark)

    Enemark, Stig; Ahene, Rexford

    2003-01-01

    development in this area. Furthermore, capacity building should ensure that the focus is on building sound institutions and governance rather than just high-level IT-infrastructures.    This overall approach to capacity building in land management is used for implementing a new land policy reform in Malawi......There is a significant need for capacity building in the interdisciplinary area of land management especially in developing countries and countries in transition, to deal with the complex issues of building efficient land information systems and sustainable institutional infrastructures. Capacity...... building in land management is not only a question of establishing a sufficient technological level or sufficient economic resources. It is mainly a question of understanding the interdisciplinary and cross-sectoral nature of land administration systems, and understanding the need for human resource...

  5. Heat Pumps With Direct Expansion Solar Collectors

    Science.gov (United States)

    Ito, Sadasuke

    In this paper, the studies of heat pump systems using solar collectors as the evaporators, which have been done so far by reserchers, are reviwed. Usually, a solar collector without any cover is preferable to one with ac over because of the necessity of absorbing heat from the ambient air when the intensity of the solar energy on the collector is not enough. The performance of the collector depends on its area and the intensity of the convective heat transfer on the surface. Fins are fixed on the backside of the collector-surface or on the tube in which the refrigerant flows in order to increase the convective heat transfer. For the purpose of using a heat pump efficiently throughout year, a compressor with variable capacity is applied. The solar assisted heat pump can be used for air conditioning at night during the summer. Only a few groups of people have studied cooling by using solar assisted heat pump systems. In Japan, a kind of system for hot water supply has been produced commercially in a company and a kind of system for air conditioning has been installed in buildings commercially by another company.

  6. Current and future prospects for heat recovery from waste in European district heating systems: A literature and data review

    DEFF Research Database (Denmark)

    Persson, Urban; Münster, Marie

    2016-01-01

    Municipal solid waste has seen increasing annual volumes for many decades in contemporary Europe and constitutes, if not properly managed, an environmental problem due to local pollution and greenhouse gas emissions. From an energy perspective, waste is also an alternative fuel for power and heat...... heat distribution infrastructures, without which no large-scale recovery and utilisation of excess heat is possible. In this paper, which aims to estimate municipal solid waste volumes available for heat recovery in European district heating systems in 2030, a literature and data review is performed...... to establish and assess current and future EU (European Union) waste generation and management. Main conclusions are that more heat can be recovered from current Waste-to-Energy facilities operating at low average heat recovery efficiencies, that efficient incineration capacity is geographically concentrated...

  7. High-Capacity Spacesuit Evaporator Absorber Radiator (SEAR)

    Science.gov (United States)

    Izenson, Michael G.; Chen, Weibo; Phillips, Scott; Chepko, Ariane; Bue, Grant; Quinn, Gregory

    2015-01-01

    Future human space exploration missions will require advanced life support technology that can operate across a wide range of applications and environments. Thermal control systems for space suits and spacecraft will need to meet critical requirements for water conservation and multifunctional operation. This paper describes a Space Evaporator Absorber Radiator (SEAR) that has been designed to meet performance requirements for future life support systems. A SEAR system comprises a lithium chloride absorber radiator (LCAR) for heat rejection coupled with a space water membrane evaporator (SWME) for heat acquisition. SEAR systems provide heat pumping to minimize radiator size, thermal storage to accommodate variable environmental conditions, and water absorption to minimize use of expendables. We have built and tested a flight-like, high-capacity LCAR, demonstrated its performance in thermal vacuum tests, and explored the feasibility of an ISS demonstration test of a SEAR system. The new LCAR design provides the same cooling capability as prior LCAR prototypes while enabling over 30% more heat absorbing capacity. Studies show that it should be feasible to demonstrate SEAR operation in flight by coupling with an existing EMU on the space station.

  8. Contribution of domestic heating systems to smart grid control

    DEFF Research Database (Denmark)

    Tahersima, Fatemeh; Stoustrup, Jakob; Meybodi, Soroush Afkhami

    2011-01-01

    . We have investigated how much power imbalance could be compensated, provided that a certain, yet user adjustable, level of residents' thermal comfort is satisfied. It is shown that the large heat capacity of the concrete floor alleviates undesired temperature fluctuations. Therefore, incorporating......How and to what extent, domestic heating systems can be helpful in regaining power balance in a smart grid, is the question to be answered in this paper. Our case study is an under-floor heating system supplied with a geothermal heat pump which is driven by electrical power from the grid. The idea...

  9. Information entropy and its application in heat conduction

    Science.gov (United States)

    Su, C. Q.; Wu, Y.; Fan, X. Y.; Guo, P.

    2017-11-01

    In this paper, heat conduction problems are analyzed from the view of information entropy. The variation law of temperature with time in the lumped-heat-capacity system can be expressed in the form of exponential distribution. It is proved that exponential distribution is the solution of a conditional extreme value problem with information entropy as an objective function. The general analysis procedure of heat conduction problems from the view of information entropy is proposed. Fundamental solution of heat conduction equation can be written in the form of normal distribution, and normal distribution can be derived from the maximum entropy principle.

  10. Heat Pipe Technology

    Science.gov (United States)

    1981-01-01

    The heat pipe, a sealed chamber whose walls are lined with a "wick," a thin capillary network containing a working fluid in liquid form was developed for a heat distribution system for non-rotating satellites. Use of the heat pipe provides a continuous heat transfer mechanism. "Heat tubes" that improve temperature control in plastics manufacturing equipment incorporated the heat pipe technology. James M. Stewart, an independent consultant, patented the heat tubes he developed and granted a license to Kona Corporation. The Kona Nozzle for heaterless injection molding gets heat for its operation from an external source and has no internal heating bands, reducing machine maintenance and also eliminating electrical hazards associated with heater bands. The nozzles are used by Eastman Kodak, Bic Pen Corporation, Polaroid, Tupperware, Ford Motor Company, RCA, and Western Electric in the molding of their products.

  11. Basic heat transfer

    CERN Document Server

    Bacon, D H

    2013-01-01

    Basic Heat Transfer aims to help readers use a computer to solve heat transfer problems and to promote greater understanding by changing data values and observing the effects, which are necessary in design and optimization calculations.The book is concerned with applications including insulation and heating in buildings and pipes, temperature distributions in solids for steady state and transient conditions, the determination of surface heat transfer coefficients for convection in various situations, radiation heat transfer in grey body problems, the use of finned surfaces, and simple heat exc

  12. Ideal Heat Exchange System

    Science.gov (United States)

    Tsirlin, A. M.

    2017-09-01

    The requirements with which a heat exchange system should comply in order that at certain values of the total contact surface and heat load the entropy production in it should be minimal have been determined. It has been shown that this system can serve as a standard for real systems of irreversible heat exchange. We have found the conditions for physical realizability of a heat exchange system in which heat exchange occurs by a law linear with respect to the temperature difference between contacting flows. Analogous conditions are given without deriving for the case of heat exchange by the Fourier law.

  13. Microscale Regenerative Heat Exchanger

    Science.gov (United States)

    Moran, Matthew E.; Stelter, Stephan; Stelter, Manfred

    2006-01-01

    The device described herein is designed primarily for use as a regenerative heat exchanger in a miniature Stirling engine or Stirling-cycle heat pump. A regenerative heat exchanger (sometimes called, simply, a "regenerator" in the Stirling-engine art) is basically a thermal capacitor: Its role in the Stirling cycle is to alternately accept heat from, then deliver heat to, an oscillating flow of a working fluid between compression and expansion volumes, without introducing an excessive pressure drop. These volumes are at different temperatures, and conduction of heat between these volumes is undesirable because it reduces the energy-conversion efficiency of the Stirling cycle.

  14. Individual differences in working memory capacity and workload capacity

    Directory of Open Access Journals (Sweden)

    Ju-Chi eYu

    2014-12-01

    Full Text Available We investigated the relationship between working memory capacity (WMC and workload capacity (WLC. Each participant performed an operation span (OSPAN task to measure his/her WMC and three redundant-target detection tasks to measure his/her WLC. WLC was computed non-parametrically (Experiments 1 and 2 and parametrically (Experiment 2. Both levels of analyses showed that participants high in WMC had larger WLC than those low in WMC only when redundant information came from visual and auditory modalities, suggesting that high-WMC participants had superior processing capacity in dealing with redundant visual and auditory information. This difference was eliminated when multiple processes required processing for only a single working memory subsystem in a color-shape detection task and a double-dot detection task. These results highlighted the role of executive control in integrating and binding information from the two working memory subsystems for perceptual decision making.

  15. Dry and moist heat sterilisation cannot inactivate pyrogenicity of Gram positive microorganisms

    DEFF Research Database (Denmark)

    Moesby, Lise; Hansen, Erik W; Christensen, Jens D

    2005-01-01

    degrees C for 45 min reduces the interleukin-6 inducing capacity to 2% compared to untreated endospores. Dry heat treatment of S. aureus at 220 degrees C for 30 min only reduces the activity to 55%. However, after 250 degrees C for 30 min or 220 degrees C for 6h there is no detectable activity of S......In the monocytic cell line Mono Mac 6 pyrogens induce interleukin-6 secretion dose dependently. The aim of this study is to examine the interleukin-6 inducing capacity of Gram positive Staphylococcus aureus and Bacillus subtilis endospores after moist and dry heat sterilisation. Moist heat...... inducing capacity of S. aureus. On the contrary moist heat sterilisation at 134 degrees C for 10, 20 and 40 min significantly increases the interleukin-6 inducing capacity compared to untreated S. aureus. This is confirmed in the rabbit pyrogen test. Dry heat sterilisation of B. subtilis endospores at 220...

  16. Absorptive capacity and smart companies

    Directory of Open Access Journals (Sweden)

    Patricia Moro González

    2014-12-01

    Full Text Available Purpose: The current competitive environment is substantially modifying the organizations’ learning processes due to a global increase of available information allowing this to be transformed into knowledge. This opportunity has been exploited since the nineties by the tools of “Business Analytics” and “Business Intelligence” but, nevertheless, being integrated in the study of new organizational capacities engaged in the process of creating intelligence inside organizations is still an outstanding task. The review of the concept of absorptive capacity and a detailed study from the perspective of this new reality will be the main objective of study of this paper.Design/methodology/approach: By comparing classical absorptive capacity and absorptive capacity from the point of view of information management tools in each one of the three stages of the organizational learning cycle, some gaps of the former are overcome/fulfilled. The academic/bibliographical references provided in this paper have been obtained from ISI web of knowledge, Scopus and Dialnet data bases, supporting the state of affairs on absorptive capacity and thereafter filtering by "Business Intelligence" and "Business Analytics". Specialized websites and Business Schools` Publications there have also been included, crowning the content on information management tools used that are currently used in the strategic consulting.Findings: Our contribution to the literature is the development of "smart absorptive capacity". This is a new capacity emerging from the reformulation of the classical concept of absorptive capacity wherein some aspects of its definition that might have been omitted are emphasized. The result of this new approach is the creation of a new Theoretical Model of Organizational Intelligence, which aims to explain, within the framework of the Resources and Capabilities Theory, the competitive advantage achieved by the so-called smart companies

  17. Solar dynamic heat rejection technology. Task 2: Heat pipe radiator development

    Science.gov (United States)

    League, Mark; Alario, Joe

    1988-05-01

    This report covers the design, fabrication, and test of several dual slot heat pipe engineering development units. The following dual-slot heat pipes were fabricated and tested: two 6-ft. aluminum heat pipes; a 20-ft. aluminum heat pipe; and a 20-ft. aluminum heat pipe with a four-leg evaporator section. The test results of all four test articles are presented and compared to the performance predicted by the design software. Test results from the four-leg article are incomplete. The methodology for fabricating stainless steel dual slot heat pipes was also studied by performing a tool life test with different single point cutters, and these results are also presented. Although the dual-slot heat pipe has demonstrated the potential to meet the requirements for a high capacity radiator system, uncertainties with the design still exist. The startup difficulties with the aluminum test articles must be solved, and a stainless steel/methanol heat pipe should be built and tested.

  18. Heat-Related Illnesses

    Medline Plus

    Full Text Available ... Be Prepared Safe Citizen Day Organize Important Medical Information ER Checklists Preparing for Emergencies Be ready to ... anyone can be affected. Here you will find information about heat cramps and heat stroke and exhaustion. ...

  19. Convective heat transfer

    CERN Document Server

    Kakac, Sadik; Pramuanjaroenkij, Anchasa

    2014-01-01

    Intended for readers who have taken a basic heat transfer course and have a basic knowledge of thermodynamics, heat transfer, fluid mechanics, and differential equations, Convective Heat Transfer, Third Edition provides an overview of phenomenological convective heat transfer. This book combines applications of engineering with the basic concepts of convection. It offers a clear and balanced presentation of essential topics using both traditional and numerical methods. The text addresses emerging science and technology matters, and highlights biomedical applications and energy technologies. What’s New in the Third Edition: Includes updated chapters and two new chapters on heat transfer in microchannels and heat transfer with nanofluids Expands problem sets and introduces new correlations and solved examples Provides more coverage of numerical/computer methods The third edition details the new research areas of heat transfer in microchannels and the enhancement of convective heat transfer with nanofluids....

  20. Heat resistant microorganism

    NARCIS (Netherlands)

    Berendsen, Erwin M.; Bennik, Maria H.J.; Kuipers, Oscar

    2015-01-01

    The invention relates to a kit and methods and means for the determination of the presence of heat resistant organisms. The invention further relates to the provision organisms wherein the heat resistance is modulated.

  1. Heat-Related Illnesses

    Medline Plus

    Full Text Available ... heat stroke and exhaustion. Heat Cramps Symptoms include muscle spasms, usually in the legs and stomach area. ... Z Teeth (Dental Emergencies) Sprains and Strains Head Injury Resources Home Safety Checklist ACEP Coloring Book Download ...

  2. Hydrothermal industrialization: direct heat development. Final report

    Energy Technology Data Exchange (ETDEWEB)

    1982-05-01

    A description of hydrothermal resources suitable for direct applications, their associated temperatures, geographic distribution and developable capacity are given. An overview of the hydrothermal direct-heat development infrastructure is presented. Development activity is highlighted by examining known and planned geothermal direct-use applications. Underlying assumptions and results for three studies conducted to determine direct-use market penetration of geothermal energy are discussed.

  3. Improving efficiency of heat recovery steam generators

    Energy Technology Data Exchange (ETDEWEB)

    Ganapathy, V. [ABCO Industries, Abilene, TX (United States)

    1996-10-01

    Gas Turbine Heat Recovery Steam Generators (HRSGs) are widely used in cogeneration and combined cycle plants. Single pressure HRSGs are preferred in small capacity units, while larger units can justify multiple pressure level steam generation, which improves the efficiency of energy recovery. This paper reviews a few methods of improving the efficiency of single and multiple pressure HRSGs, which may be of interest to consultants and plant engineers, who are planning new cogeneration projects.

  4. Modeling and Dimensioning Ground Heat Exchangers Principles: Influence of the soil's thermal proprieties

    OpenAIRE

    Lavoué, Francois; Tourancheau, Bernard

    2010-01-01

    International audience; In the context of energy crisis and global warming, heating buildings with the solar energy stored in the soil rep- resents a very interesting alternative. Moreover, cooling buildings can also use the soil damping capacity. This paper presents our reflexion about the modeling and dimensioning of the ground heat exchanger part of ground-coupled heat pumps (GCHP). After a physical overview of the ground heat exchanger, we extract from analytical solutions practical conse...

  5. Calculation methods for SPF for heat pump systems for comparison, system choice and dimensioning

    Energy Technology Data Exchange (ETDEWEB)

    Nordman, Roger; Andersson, Kajsa; Axell, Monica; Lindahl, Markus

    2010-09-15

    In this project, results from field measurements of heat pumps have been collected and summarised. Also existing calculation methods have been compared and summarised. Analyses have been made on how the field measurements compare to existing calculation models for heat pumps Seasonal Performance Factor (SPF), and what deviations may depend on. Recommendations for new calculation models are proposed, which include combined systems (e.g. solar - HP), capacity controlled heat pumps and combined DHW and heating operation

  6. High Temperature Metal Hydrides as Heat Storage Materials for Solar and Related Applications

    Directory of Open Access Journals (Sweden)

    Borislav Bogdanović

    2009-01-01

    Full Text Available For the continuous production of electricity with solar heat power plants the storage of heat at a temperature level around 400 °C is essential. High temperature metal hydrides offer high heat storage capacities around this temperature. Based on Mg-compounds, these hydrides are in principle low-cost materials with excellent cycling stability. Relevant properties of these hydrides and their possible applications as heat storage materials are described.

  7. Isolated quantum heat engine.

    Science.gov (United States)

    Fialko, O; Hallwood, D W

    2012-02-24

    We present a theoretical and numerical analysis of a quantum system that is capable of functioning as a heat engine. This system could be realized experimentally using cold bosonic atoms confined to a double well potential that is created by splitting a harmonic trap with a focused laser. The system shows thermalization, and can model a reversible heat engine cycle. This is the first demonstration of the operation of a heat engine with a finite quantum heat bath.

  8. Isolated quantum heat engine

    OpenAIRE

    Fialko, O.; Hallwood, D.

    2011-01-01

    We present a theoretical and numerical analysis of a quantum system that is capable of functioning as a heat engine. This system could be realized experimentally using cold bosonic atoms confined to a double well potential that is created by splitting a harmonic trap with a focused laser. The system shows thermalization, and can model a reversible heat engine cycle. This is the first demonstration of the operation of a heat engine with a finite quantum heat bath.

  9. Solar heat receiver

    Science.gov (United States)

    Hunt, Arlon J.; Hansen, Leif J.; Evans, David B.

    1985-01-01

    A receiver for converting solar energy to heat a gas to temperatures from 700.degree.-900.degree. C. The receiver is formed to minimize impingement of radiation on the walls and to provide maximum heating at and near the entry of the gas exit. Also, the receiver is formed to provide controlled movement of the gas to be heated to minimize wall temperatures. The receiver is designed for use with gas containing fine heat absorbing particles, such as carbon particles.

  10. Warfare, Fiscal Capacity, and Performance

    DEFF Research Database (Denmark)

    Prado, Mauricio; Dincecco, Mark

    We exploit differences in casualties sustained in pre-modern wars to estimate the impact of fiscal capacity on economic performance. In the past, states fought different amounts of external conflicts, of various lengths and magnitudes. To raise the revenues to wage wars, states made fiscal...... innovations, which persisted and helped to shape current fiscal institutions. Economic historians claim that greater fiscal capacity was the key long-run institutional change brought about by historical conflicts. Using casualties sustained in pre-modern wars to instrument for current fiscal institutions, we...... estimate substantial impacts of fiscal capacity on GDP per worker. The results are robust to a broad range of specifications, controls, and sub-samples....

  11. Warfare, Fiscal Capacity, and Performance

    DEFF Research Database (Denmark)

    Dincecco, Mark; Prado, Mauricio

    2012-01-01

    We exploit differences in casualties sustained in pre-modern wars to estimate the impact of fiscal capacity on economic performance. In the past, states fought different amounts of external conflicts, of various lengths and magnitudes. To raise the revenues to wage wars, states made fiscal...... innovations, which persisted and helped to shape current fiscal institutions. Economic historians claim that greater fiscal capacity was the key long-run institutional change brought about by historical conflicts. Using casualties sustained in pre-modern wars to instrument for current fiscal institutions, we...... estimate substantial impacts of fiscal capacity on GDP per worker. The results are robust to a broad range of specifications, controls, and sub-samples....

  12. The Innovative Capacity of Firms

    Directory of Open Access Journals (Sweden)

    Neely Andy

    2014-11-01

    Full Text Available Innovation is widely accepted as a crucial competitive weapon in today's global market place. Yet the levels of innovation achieved by different firms, even within the same industry, can vary widely. The key question raised by this observation is why. Why are some firms more innovative than others? What are the factors that determine a firm's capacity to innovate and how can these be managed to enhance the firm's innovative potential? This paper sets out to address these and related issues. It reports the results of a study of competitiveness and innovation of firms in the East of England. In the paper it is argued that the innovative capacity of a firm is a function of the firm's culture, resources, competences and networks. Justification for this framework is provided by a review of the relevant literature and a series of case studies examining the capacity to innovate of a sample of firms in the East of England.

  13. Heat-Related Illnesses

    Science.gov (United States)

    ... this! Home » Emergency 101 Heat-Related Illnesses Dr. Glenn Mitchell , Emergency physician at Mercy Health System in Chesterfield, Missouri Heat-related illness can be caused by overexposure to the sun or any situation that involves extreme heat. Young children and the elderly are most at risk, ...

  14. Heat-Related Illnesses

    Medline Plus

    Full Text Available ... this! Home » Emergency 101 Heat-Related Illnesses Dr. Glenn Mitchell , Emergency physician at Mercy Health System in Chesterfield, Missouri Heat-related illness can be caused by overexposure to the sun or any situation that involves extreme heat. Young children and the elderly are most at risk, ...

  15. Heat roadmap China

    DEFF Research Database (Denmark)

    Xiong, Weiming; Wang, Yu; Mathiesen, Brian Vad

    2015-01-01

    District heating is regarded as a key element of energy saving actions in the Chinese national energy strategy, while space heating in China is currently still dominated by coal boilers. However, there is no existing quantitative study to analyse the future heat strategy for China. Therefore...

  16. Microwave processing heats up

    Science.gov (United States)

    Microwaves are a common appliance in many households. In the United States microwave heating is the third most popular domestic heating method food foods. Microwave heating is also a commercial food processing technology that has been applied for cooking, drying, and tempering foods. It's use in ...

  17. Single Electrode Heat Effects

    DEFF Research Database (Denmark)

    Jacobsen, Torben; Broers, G. H. J.

    1977-01-01

    The heat evolution at a single irreversibly working electrode is treated onthe basis of the Brønsted heat principle. The resulting equation is analogous to the expression for the total heat evolution in a galvanic cellwith the exception that –DeltaS is substituted by the Peltier entropy, Delta...

  18. Champagne Heat Pump

    Science.gov (United States)

    Jones, Jack A.

    2004-01-01

    The term champagne heat pump denotes a developmental heat pump that exploits a cycle of absorption and desorption of carbon dioxide in an alcohol or other organic liquid. Whereas most heat pumps in common use in the United States are energized by mechanical compression, the champagne heat pump is energized by heating. The concept of heat pumps based on other absorption cycles energized by heat has been understood for years, but some of these heat pumps are outlawed in many areas because of the potential hazards posed by leakage of working fluids. For example, in the case of the water/ammonia cycle, there are potential hazards of toxicity and flammability. The organic-liquid/carbon dioxide absorption/desorption cycle of the champagne heat pump is similar to the water/ammonia cycle, but carbon dioxide is nontoxic and environmentally benign, and one can choose an alcohol or other organic liquid that is also relatively nontoxic and environmentally benign. Two candidate nonalcohol organic liquids are isobutyl acetate and amyl acetate. Although alcohols and many other organic liquids are flammable, they present little or no flammability hazard in the champagne heat pump because only the nonflammable carbon dioxide component of the refrigerant mixture is circulated to the evaporator and condenser heat exchangers, which are the only components of the heat pump in direct contact with air in habitable spaces.

  19. Heat pipes for industrial waste heat recovery

    Science.gov (United States)

    Merrigan, M. A.

    1981-01-01

    Development work on the high temperature ceramic recuperator at Los Alamos National Laboratory is described and involved material investigations, fabrication methods development, compatibility tests, heat pipe operation, and the modeling of application conditions based on current industrial usage. Solid ceramic heat pipes, ceramic coated refractory pipes, and high-temperature oxide protected metallic pipes are investigated. Economic studies of the use of heat pipe based recuperators in industrial furnaces are conducted and payback periods determined as a function of material, fabrication, and installation cost.

  20. Geothermal heat in a heat pump use

    Science.gov (United States)

    Pavlova, A.; Hansen, J.; Obermeyer, H.; Pavlova, I.

    2016-09-01

    The considered innovative technology proposes to use alternative energy sources for the process efficiency in low-height construction. The world economy depends on price rises for energy sources and the danger of environmental pollution increases. Geothermal energy is the basic resource saving and environmentally safe renewable heat source that is characterized by inexhaustibility, permanent all the-year-round use, universal prevalence of resources and the ability to replace considerable volumes of traditional energy carriers. The expediency and power efficiency to apply a heat pump with the use of geothermal heat is proved for low-height construction.