WorldWideScience

Sample records for heart rate qrs

  1. QRS peak detection for heart rate monitoring on Android smartphone

    Science.gov (United States)

    Pambudi Utomo, Trio; Nuryani, Nuryani; Darmanto

    2017-11-01

    In this study, Android smartphone is used for heart rate monitoring and displaying electrocardiogram (ECG) graph. Heart rate determination is based on QRS peak detection. Two methods are studied to detect the QRS complex peak; they are Peak Threshold and Peak Filter. The acquisition of ECG data is utilized by AD8232 module from Analog Devices, three electrodes, and Microcontroller Arduino UNO R3. To record the ECG data from a patient, three electrodes are attached to particular body’s surface of a patient. Patient’s heart activity which is recorded by AD8232 module is decoded by Arduino UNO R3 into analog data. Then, the analog data is converted into a voltage value (mV) and is processed to get the QRS complex peak. Heart rate value is calculated by Microcontroller Arduino UNO R3 uses the QRS complex peak. Voltage, heart rate, and the QRS complex peak are sent to Android smartphone by Bluetooth HC-05. ECG data is displayed as the graph by Android smartphone. To evaluate the performance of QRS complex peak detection method, three parameters are used; they are positive predictive, accuracy and sensitivity. Positive predictive, accuracy, and sensitivity of Peak Threshold method is 92.39%, 70.30%, 74.62% and for Peak Filter method are 98.38%, 82.47%, 83.61%, respectively.

  2. Pharmacokinetic-pharmacodynamic modeling of QRS-prolongation by flecainide: heart rate-dependent effects during sinus rhythm in conscious telemetered dogs.

    Science.gov (United States)

    Sällström, Johan; Al-Saffar, Ahmad; Pehrson, Rikard

    2014-01-01

    The duration of the QRS interval is determined by the ion currents involved in cardiac depolarization. Class I antiarrhythmic drugs reduce cardiac excitability and conduction by inhibiting Nav1.5 channels responsible for I(Na), thus increasing the QRS interval. Previous studies in humans as well as in animal models have demonstrated a more pronounced effect on QRS-prolongation during higher heart rates. In the present study, the effects of the Nav1.5 inhibitor flecainide on cardiovascular parameters, were studied in the telemetered beagle dog under normal autonomic control. The heart rate dependency of QRS prolongation was characterized using pharmacokinetic-pharmacodynamic (PKPD) modeling. Four male telemetered beagle dogs were administered placebo or flecainide (100, 150 and 200 mg) in a Latin square design. The QRS interval and heart rate were recorded, and blood samples were taken. Plasma concentrations of flecainide were fitted to a one compartment oral model and the intrapolated plasma concentrations were fitted to QRS and heart rate data sampled during 5 h after dosing. Flecainide increased the QRS interval in all dogs, whereas there were no effects on heart rate. Using the PKPD model, a statistically significant heart rate-dependent QRS prolongation was linked to individual concentration-time profiles of flecainide. PKPD analysis of QRS interval data from unrestrained dogs with sinus rhythm can elucidate mechanisms previously only described during controlled heart rhythm. Specific questions can therefore be addressed in generically designed cardiovascular telemetry safety studies and different types of relationships between parameters can be uncovered. In addition, the present approach can be used to better characterize drug-induced QRS effects in cardiovascular dog models. © 2013.

  3. Fetal QRS detection and heart rate estimation: a wavelet-based approach

    International Nuclear Information System (INIS)

    Almeida, Rute; Rocha, Ana Paula; Gonçalves, Hernâni; Bernardes, João

    2014-01-01

    Fetal heart rate monitoring is used for pregnancy surveillance in obstetric units all over the world but in spite of recent advances in analysis methods, there are still inherent technical limitations that bound its contribution to the improvement of perinatal indicators. In this work, a previously published wavelet transform based QRS detector, validated over standard electrocardiogram (ECG) databases, is adapted to fetal QRS detection over abdominal fetal ECG. Maternal ECG waves were first located using the original detector and afterwards a version with parameters adapted for fetal physiology was applied to detect fetal QRS, excluding signal singularities associated with maternal heartbeats. Single lead (SL) based marks were combined in a single annotator with post processing rules (SLR) from which fetal RR and fetal heart rate (FHR) measures can be computed. Data from PhysioNet with reference fetal QRS locations was considered for validation, with SLR outperforming SL including ICA based detections. The error in estimated FHR using SLR was lower than 20 bpm for more than 80% of the processed files. The median error in 1 min based FHR estimation was 0.13 bpm, with a correlation between reference and estimated FHR of 0.48, which increased to 0.73 when considering only records for which estimated FHR > 110 bpm. This allows us to conclude that the proposed methodology is able to provide a clinically useful estimation of the FHR. (paper)

  4. Myocardial ischemia analysis based on electrocardiogram QRS complex

    International Nuclear Information System (INIS)

    Song, J.; Yan, H.; Xu, Z.; Yu, X.; Zhu, R.

    2011-01-01

    Full text: Electrocardiogram (ECG) is an economic, convenient, and non-invasive detecting tool in myocardial ischemia (MI), and its clinical appearance is mainly exhibited by the changes in ST-T complex. Recently, QRS complex characters were proposed to analyze MI by more and more researchers. In this paper, various QRS complex characters were extracted in ECG signals, and their relationship was analyzed systematically. As a result, these characters were divided into two groups, and there existed good relationship among them for each group, while the poor relationship between the groups. Then these QRS complex characters were applied for statistical analysis on MI, and five characters had significant differences after ECG recording verification, which were: QRS upward and downward slopes, transient heart rate, angle R and angle Q. On the other hand, these QRS complex characters were analyzed in frequency domain. Experimental results showed that the frequency features of RR interval series (Heart Rate Variability, HRV), and QRS barycenter sequence had signjficant differences between MI states and normal states. Moreover, QRS barycenter sequence performed better. (author)

  5. Comparison of QRS Duration and Associated Cardiovascular Events in American Indian Men Versus Women (The Strong Heart Study).

    Science.gov (United States)

    Deen, Jason F; Rhoades, Dorothy A; Noonan, Carolyn; Best, Lyle G; Okin, Peter M; Devereux, Richard B; Umans, Jason G

    2017-06-01

    Electrocardiographic QRS duration at rest is associated with sudden cardiac death and death from coronary heart disease in the general population. However, its relation to cardiovascular events in American Indians, a population with persistently high cardiovascular disease mortality, is unknown. The relation of QRS duration to incident cardiovascular disease during 17.2 years of follow-up was assessed in 1,851 male and female Strong Heart Study participants aged 45 to 74 years without known cardiovascular disease at baseline. Cox regression with robust standard error estimates was used to determine the association between quintiles of QRS duration and incident cardiovascular disease in gender-stratified analyses, adjusted for age, systolic blood pressure, hypertension, antihypertensive medication use, body mass index, current smoking, diabetes, total cholesterol, high-density lipoprotein cholesterol, and albuminuria. In women only, QRS duration in the highest quintile (≥105 ms) conferred significantly higher risk of cardiovascular disease than QRS duration in the lowest quintile (64 to 84 ms) (hazard ratio 1.6, 95% CI 1.1 to 2.4) likely because of higher risks of coronary heart disease (hazard ratio 1.8, 95% CI 1.1 to 3.1) and myocardial infarction (hazard ratio 2.1, 95% CI 1.0 to 4.7). Furthermore, when added to the Strong Heart Study Coronary Heart Disease Risk Calculator, QRS duration significantly improved prediction of future coronary heart disease events in women (Net Reclassification Index 0.17, 95% CI 0.06 to 0.47). In conclusion, QRS duration is an independent predictor of cardiovascular disease in women in the Strong Heart Study cohort and may have value in estimating risk in populations with similar risk profiles and a high lifetime incidence of cardiovascular disease. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Detecting drug-induced prolongation of the QRS complex: New insights for cardiac safety assessment

    Energy Technology Data Exchange (ETDEWEB)

    Cros, C., E-mail: caroline.cros@hotmail.co.uk [Safety Pharmacology, Global Safety Assessment, Safety Assessment UK, AstraZeneca R and D, Alderley Park, Macclesfield, SK10 4TG (United Kingdom); Skinner, M., E-mail: Matthew.Skinner@astrazeneca.com [Safety Pharmacology, Global Safety Assessment, Safety Assessment UK, AstraZeneca R and D, Alderley Park, Macclesfield, SK10 4TG (United Kingdom); Moors, J. [Safety Pharmacology, Global Safety Assessment, Safety Assessment UK, AstraZeneca R and D, Alderley Park, Macclesfield, SK10 4TG (United Kingdom); Lainee, P. [Sanofi-Aventis R and D, 371, rue du Pr Joseph Blayac, 34184 Montpellier Cedex 04 (France); Valentin, J.P. [Safety Pharmacology, Global Safety Assessment, Safety Assessment UK, AstraZeneca R and D, Alderley Park, Macclesfield, SK10 4TG (United Kingdom)

    2012-12-01

    Background: Drugs slowing the conduction of the cardiac action potential and prolonging QRS complex duration by blocking the sodium current (I{sub Na}) may carry pro-arrhythmic risks. Due to the frequency-dependent block of I{sub Na}, this study assesses whether activity-related spontaneous increases in heart rate (HR) occurring during standard dog telemetry studies can be used to optimise the detection of class I antiarrhythmic-induced QRS prolongation. Methods: Telemetered dogs were orally dosed with quinidine (class Ia), mexiletine (class Ib) or flecainide (class Ic). QRS duration was determined standardly (5 beats averaged at rest) but also prior to and at the plateau of each acute increase in HR (3 beats averaged at steady state), and averaged over 1 h period from 1 h pre-dose to 5 h post-dose. Results: Compared to time-matched vehicle, at rest, only quinidine and flecainide induced increases in QRS duration (E{sub max} 13% and 20% respectively, P < 0.01–0.001) whereas mexiletine had no effect. Importantly, the increase in QRS duration was enhanced at peak HR with an additional effect of + 0.7 ± 0.5 ms (quinidine, NS), + 1.8 ± 0.8 ms (mexiletine, P < 0.05) and + 2.8 ± 0.8 ms (flecainide, P < 0.01) (calculated as QRS at basal HR-QRS at high HR). Conclusion: Electrocardiogram recordings during elevated HR, not considered during routine analysis optimised for detecting QT prolongation, can be used to sensitise the detection of QRS prolongation. This could prove useful when borderline QRS effects are detected. Analysing during acute increases in HR could also be useful for detecting drug-induced effects on other aspects of cardiac function. -- Highlights: ► We aimed to improve detection of drug-induced QRS prolongation in safety screening. ► We used telemetered dogs to test class I antiarrhythmics at low and high heart rate. ► At low heart rate only quinidine and flecainide induced an increase in QRS duration. ► At high heart rate the effects of two

  7. Detecting drug-induced prolongation of the QRS complex: New insights for cardiac safety assessment

    International Nuclear Information System (INIS)

    Cros, C.; Skinner, M.; Moors, J.; Lainee, P.; Valentin, J.P.

    2012-01-01

    Background: Drugs slowing the conduction of the cardiac action potential and prolonging QRS complex duration by blocking the sodium current (I Na ) may carry pro-arrhythmic risks. Due to the frequency-dependent block of I Na , this study assesses whether activity-related spontaneous increases in heart rate (HR) occurring during standard dog telemetry studies can be used to optimise the detection of class I antiarrhythmic-induced QRS prolongation. Methods: Telemetered dogs were orally dosed with quinidine (class Ia), mexiletine (class Ib) or flecainide (class Ic). QRS duration was determined standardly (5 beats averaged at rest) but also prior to and at the plateau of each acute increase in HR (3 beats averaged at steady state), and averaged over 1 h period from 1 h pre-dose to 5 h post-dose. Results: Compared to time-matched vehicle, at rest, only quinidine and flecainide induced increases in QRS duration (E max 13% and 20% respectively, P < 0.01–0.001) whereas mexiletine had no effect. Importantly, the increase in QRS duration was enhanced at peak HR with an additional effect of + 0.7 ± 0.5 ms (quinidine, NS), + 1.8 ± 0.8 ms (mexiletine, P < 0.05) and + 2.8 ± 0.8 ms (flecainide, P < 0.01) (calculated as QRS at basal HR-QRS at high HR). Conclusion: Electrocardiogram recordings during elevated HR, not considered during routine analysis optimised for detecting QT prolongation, can be used to sensitise the detection of QRS prolongation. This could prove useful when borderline QRS effects are detected. Analysing during acute increases in HR could also be useful for detecting drug-induced effects on other aspects of cardiac function. -- Highlights: ► We aimed to improve detection of drug-induced QRS prolongation in safety screening. ► We used telemetered dogs to test class I antiarrhythmics at low and high heart rate. ► At low heart rate only quinidine and flecainide induced an increase in QRS duration. ► At high heart rate the effects of two out of three

  8. Prolonged QRS Widening After Aripiprazole Overdose.

    Science.gov (United States)

    Mazer-Amirshahi, Maryann; Porter, Robert; Dewey, Kayla

    2018-05-05

    Aripiprazole is an atypical antipsychotic with a long half-life. Overdose can result in protracted somnolence and cardiac disturbances, particularly QT interval prolongation. This is a single case report of a 14-year-old boy who took an overdose of aripiprazole and developed QRS widening. A 14-year-old boy intentionally ingested 20 tablets of aripiprazole (5 mg). He was brought to the emergency department when his ingestion was discovered. The patient's vital signs were as follows: temperature, 37.7°C; heart rate, 108 beats/min; blood pressure, 138/98 mm Hg; and respirations, 16 breaths/min. Activated charcoal was administered within 90 minutes of ingestion. Initial electrocardiogram (EKG) showed sinus tachycardia, with a QRS of 138 ms and QT interval of 444 ms. QRS duration was 90 ms on an EKG performed 3 months earlier. A bolus of sodium bicarbonate was administered, and the patient was transferred to the pediatric intensive care unit. Repeat EKG demonstrated a QRS of 156 ms, and a sodium bicarbonate infusion was initiated. The patient continued to have QRS prolongation for the next 8 days, reaching a peak of 172 ms 3 days postingestion. Despite aggressive treatment with sodium bicarbonate, there was persistent QRS prolongation; however, the patient did not have any dysrhythmias and remained hemodynamically stable. The patient was discharged 9 days postingestion when the QRS duration normalized to 82 ms. Genetic testing revealed that the patient was a CYP2D6 poor metabolizer. This case suggests that aripiprazole toxicity may possibly be associated with QRS prolongation without associated dysrhythmias or cardiovascular compromise. In addition, toxicity may be prolonged in patients who are CYP2D6 poor metabolizers.

  9. "Heart rate-dependent" electrocardiographic diagnosis of left ventricular hypertrophy.

    Science.gov (United States)

    Madias, John E

    2013-05-01

    A case is presented revealing the common phenomenon of heart rate-dependent diagnosis of electrocardiographic (ECG) diagnosis of left ventricular hypertrophy (LVH), which consists of satisfaction of LVH criteria only at faster rates whereas ECGs with a slow heart rate do not satisfy such criteria. The mechanism of the phenomenon has been attributed to the tachycardia-mediated underfilling of the left ventricle bringing the electrical "centroid" of the heart closer to the recording electrodes, which results in augmentation of the amplitude of QRS complexes, particularly in leads V2-V4. ©2012, The Author. Journal compilation ©2012 Wiley Periodicals, Inc.

  10. Microcontroller-based real-time QRS detection.

    Science.gov (United States)

    Sun, Y; Suppappola, S; Wrublewski, T A

    1992-01-01

    The authors describe the design of a system for real-time detection of QRS complexes in the electrocardiogram based on a single-chip microcontroller (Motorola 68HC811). A systematic analysis of the instrumentation requirements for QRS detection and of the various design techniques is also given. Detection algorithms using different nonlinear transforms for the enhancement of QRS complexes are evaluated by using the ECG database of the American Heart Association. The results show that the nonlinear transform involving multiplication of three adjacent, sign-consistent differences in the time domain gives a good performance and a quick response. When implemented with an appropriate sampling rate, this algorithm is also capable of rejecting pacemaker spikes. The eight-bit single-chip microcontroller provides sufficient throughput and shows a satisfactory performance. Implementation of multiple detection algorithms in the same system improves flexibility and reliability. The low chip count in the design also favors maintainability and cost-effectiveness.

  11. Envelopment filter and K-means for the detection of QRS waveforms in electrocardiogram.

    Science.gov (United States)

    Merino, Manuel; Gómez, Isabel María; Molina, Alberto J

    2015-06-01

    The electrocardiogram (ECG) is a well-established technique for determining the electrical activity of the heart and studying its diseases. One of the most common pieces of information that can be read from the ECG is the heart rate (HR) through the detection of its most prominent feature: the QRS complex. This paper describes an offline version and a real-time implementation of a new algorithm to determine QRS localization in the ECG signal based on its envelopment and K-means clustering algorithm. The envelopment is used to obtain a signal with only QRS complexes, deleting P, T, and U waves and baseline wander. Two moving average filters are applied to smooth data. The K-means algorithm classifies data into QRS and non-QRS. The technique is validated using 22 h of ECG data from five Physionet databases. These databases were arbitrarily selected to analyze different morphologies of QRS complexes: three stored data with cardiac pathologies, and two had data with normal heartbeats. The algorithm has a low computational load, with no decision thresholds. Furthermore, it does not require any additional parameter. Sensitivity, positive prediction and accuracy from results are over 99.7%. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.

  12. Improved symptoms, physical limitation, and self-efficacy after resynchronization in a patient with heart failure and a prolonged QRS duration.

    Science.gov (United States)

    Conaway, Darcy G; Sullivan, Robbie; McCullough, Peter A

    2004-01-01

    This report examines the impact of resynchronization therapy in a patient with class IV heart failure and a prolonged QRS duration on electrocardiogram. The Kansas City Cardiomyopathy Questionnaire (KCCQ) was used to assess the patient's health status prior to, immediately after, and 2 months after placement of a biventricular pacemaker. B-type natriuretic peptide (BNP) values and electrocardiogram QRS duration were recorded to further document clinical status. Our patient experienced statistically significant improvements in 7 of 10 KCCQ domains after resynchronization. QRS duration narrowed following the procedure and BNP values decreased. Resynchronization therapy improved this patient's symptoms, physical limitations, and self-efficacy when maximal medical therapy failed.

  13. New Mexico Look for the STARS--AIM HIGH: QRS Profile. The Child Care Quality Rating System (QRS) Assessment

    Science.gov (United States)

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of New Mexico's Look for the STARS--AIM HIGH prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for Center-Based Programs; (4)…

  14. Association between QRS duration and obstructive sleep apnea.

    Science.gov (United States)

    Gupta, Shuchita; Cepeda-Valery, Beatriz; Romero-Corral, Abel; Shamsuzzaman, Abu; Somers, Virend K; Pressman, Gregg S

    2012-12-15

    Both obstructive sleep apnea (OSA) and prolonged QRS duration are associated with hypertension, heart failure, and sudden cardiac death. However, possible links between QRS duration and OSA have not been explored. Cross-sectional study of 221 patients who underwent polysomnography at our center. Demographics, cardiovascular risk factors and ECG were collected to explore a relationship between OSA and QRS duration. The apnea-hypopnea index (AHI) was positively correlated with QRS duration (r = 0.141, p = 0.03). Patients were divided into 3 groups: AHI 30 (55). The mean QRS duration prolonged significantly as OSA worsened (AHI 30, 95 ± 19.9 ms, p = 0.001). QRS ≥ 100 ms was present in 12.7% of patients with severe OSA compared with 0% in the rest of the sample (p < 0.0001). After adjustment for age, race, and cardiovascular risk factors, this association remained significant in women but not in men. QRS duration and OSA were significantly associated. Severity of OSA independently predicted prolonged QRS in women but not men. Nevertheless, prolongation of QRS duration in either sex may potentiate arrhythmic risks associated with OSA.

  15. Differential prognostic importance of QRS duration in heart failure and acute myocardial infarction associated with left ventricular dysfunction

    DEFF Research Database (Denmark)

    Fosbøl, Emil Loldrup; Seibaek, Marie; Brendorp, Bente

    2007-01-01

    BACKGROUND/AIMS: Studies of the prognostic importance of QRS duration in patients with heart failure (HF) have shown conflicting results and few studies have estimated the importance after myocardial infarction (MI). METHODS: The Danish Investigations and Arrhythmia ON Dofetilide (DIAMOND) study...

  16. Prevalence and inter-relationship of different Doppler measures of dyssynchrony in patients with heart failure and prolonged QRS: a report from CARE-HF

    DEFF Research Database (Denmark)

    Edner, Magnus; Kim, Yong; Hansen, Knud Norregaard

    2009-01-01

    . 3(1, 4), p = 0.002, compared to patients with ischemic heart disease. CONCLUSION: The prevalence of intra-ventricular dyssynchrony is high in patients with heart failure, wide QRS and depressed systolic function. Most important, TSI appears to be a fast and reliable method to identify patients...

  17. Sequential biventricular pacing improves regional contractility, longitudinal function and dyssynchrony in patients with heart failure and prolonged QRS

    Directory of Open Access Journals (Sweden)

    Ring Margareta

    2010-04-01

    Full Text Available Abstract Aims Biventricular pacing (BiP is an effective treatment in systolic heart failure (HF patients with prolonged QRS. However, approximately 35% of the patients receiving BiP are classified as non-responders. The aim of this study is to evaluate the acute effects of VV-optimization on systolic heart function. Methods Twenty-one HF patients aged 72 (46-88 years, QRS 154 (120-190 ms, were studied with echocardiography, Tissue Doppler Imaging (TDI and 3D-echo the first day after receiving a BiP device. TDI was performed; during simultaneous pacing (LV-lead pacing 4 ms before the RV-lead and during sequential pacing (LV 20 and 40 ms before RV and RV 20 and 40 ms before LV-lead pacing. Systolic heart function was studied by tissue tracking (TT for longitudinal function and systolic maximal velocity (SMV for regional contractility and signs of dyssynchrony assessed by time-delays standard deviation of aortic valve opening to SMV, AVO-SMV/SD and tissue synchronization imaging (TSI. Results The TT mean value preoperatively was 4,2 ± 1,5 and increased at simultaneous pacing to 5,0 ± 1,2 mm (p Conclusions VV-optimization in the acute phase improves systolic heart function more than simultaneous BiP pacing. Long-term effects should be evaluated in prospective randomized trials.

  18. QRS complex detection based on continuous density hidden Markov models using univariate observations

    Science.gov (United States)

    Sotelo, S.; Arenas, W.; Altuve, M.

    2018-04-01

    In the electrocardiogram (ECG), the detection of QRS complexes is a fundamental step in the ECG signal processing chain since it allows the determination of other characteristics waves of the ECG and provides information about heart rate variability. In this work, an automatic QRS complex detector based on continuous density hidden Markov models (HMM) is proposed. HMM were trained using univariate observation sequences taken either from QRS complexes or their derivatives. The detection approach is based on the log-likelihood comparison of the observation sequence with a fixed threshold. A sliding window was used to obtain the observation sequence to be evaluated by the model. The threshold was optimized by receiver operating characteristic curves. Sensitivity (Sen), specificity (Spc) and F1 score were used to evaluate the detection performance. The approach was validated using ECG recordings from the MIT-BIH Arrhythmia database. A 6-fold cross-validation shows that the best detection performance was achieved with 2 states HMM trained with QRS complexes sequences (Sen = 0.668, Spc = 0.360 and F1 = 0.309). We concluded that these univariate sequences provide enough information to characterize the QRS complex dynamics from HMM. Future works are directed to the use of multivariate observations to increase the detection performance.

  19. Prognostic Significance of Frontal QRS-T Angle in Patients with Idiopathic Dilated Cardiomyopathy

    Directory of Open Access Journals (Sweden)

    Sheng-Na Li

    2016-01-01

    Conclusions: The frontal QRS-T angle is a powerful predictor of all-cause mortality, cardiac mortality, and worsening heart failure in IDC patients, independent of well-established prognostic factors. Optimized therapy significantly narrows the QRS-T angle, which might be an indicator of medication compliance, but this requires further investigation.

  20. Analysis Spectrum of ECG Signal and QRS Detection during Running on Treadmill

    Science.gov (United States)

    Agung Suhendra, M.; Ilham R., M.; Simbolon, Artha I.; Faizal A., M.; Munandar, A.

    2018-03-01

    The heart is an important organ in our metabolism in which it controls circulatory and oxygen. The heart exercise is needed one of them using the treadmill to prevent health. To analysis, it using electrocardiograph (ECG) to investigating and diagnosing anomalies of the heart. In this paper, we would like to analysis ECG signals during running on the treadmill with kinds of speeds. There are two analysis ECG signals i.e. QRS detection and power spectrum density (PSD). The result of PSD showed that subject 3 has highly for all subject and the result of QRS detection using pan Tomkins algorithm that a percentage of failed detection is an approaching to 0 % for all subject.

  1. Spectral analysis of time series of events: effect of respiration on heart rate in neonates

    International Nuclear Information System (INIS)

    Van Drongelen, Wim; Williams, Amber L; Lasky, Robert E

    2009-01-01

    Certain types of biomedical processes such as the heart rate generator can be considered as signals that are sampled by the occurring events, i.e. QRS complexes. This sampling property generates problems for the evaluation of spectral parameters of such signals. First, the irregular occurrence of heart beats creates an unevenly sampled data set which must either be pre-processed (e.g. by using trace binning or interpolation) prior to spectral analysis, or analyzed with specialized methods (e.g. Lomb's algorithm). Second, the average occurrence of events determines the Nyquist limit for the sampled time series. Here we evaluate different types of spectral analysis of recordings of neonatal heart rate. Coupling between respiration and heart rate and the detection of heart rate itself are emphasized. We examine both standard and data adaptive frequency bands of heart rate signals generated by models of coupled oscillators and recorded data sets from neonates. We find that an important spectral artifact occurs due to a mirror effect around the Nyquist limit of half the average heart rate. Further we conclude that the presence of respiratory coupling can only be detected under low noise conditions and if a data-adaptive respiratory band is used

  2. Robust QRS peak detection by multimodal information fusion of ECG and blood pressure signals.

    Science.gov (United States)

    Ding, Quan; Bai, Yong; Erol, Yusuf Bugra; Salas-Boni, Rebeca; Zhang, Xiaorong; Hu, Xiao

    2016-11-01

    QRS peak detection is a challenging problem when ECG signal is corrupted. However, additional physiological signals may also provide information about the QRS position. In this study, we focus on a unique benchmark provided by PhysioNet/Computing in Cardiology Challenge 2014 and Physiological Measurement focus issue: robust detection of heart beats in multimodal data, which aimed to explore robust methods for QRS detection in multimodal physiological signals. A dataset of 200 training and 210 testing records are used, where the testing records are hidden for evaluating the performance only. An information fusion framework for robust QRS detection is proposed by leveraging existing ECG and ABP analysis tools and combining heart beats derived from different sources. Results show that our approach achieves an overall accuracy of 90.94% and 88.66% on the training and testing datasets, respectively. Furthermore, we observe expected performance at each step of the proposed approach, as an evidence of the effectiveness of our approach. Discussion on the limitations of our approach is also provided.

  3. Data fusion for QRS complex detection in multi-lead electrocardiogram recordings

    Science.gov (United States)

    Ledezma, Carlos A.; Perpiñan, Gilberto; Severeyn, Erika; Altuve, Miguel

    2015-12-01

    Heart diseases are the main cause of death worldwide. The first step in the diagnose of these diseases is the analysis of the electrocardiographic (ECG) signal. In turn, the ECG analysis begins with the detection of the QRS complex, which is the one with the most energy in the cardiac cycle. Numerous methods have been proposed in the bibliography for QRS complex detection, but few authors have analyzed the possibility of taking advantage of the information redundancy present in multiple ECG leads (simultaneously acquired) to produce accurate QRS detection. In our previous work we presented such an approach, proposing various data fusion techniques to combine the detections made by an algorithm on multiple ECG leads. In this paper we present further studies that show the advantages of this multi-lead detection approach, analyzing how many leads are necessary in order to observe an improvement in the detection performance. A well known QRS detection algorithm was used to test the fusion techniques on the St. Petersburg Institute of Cardiological Technics database. Results show improvement in the detection performance with as little as three leads, but the reliability of these results becomes interesting only after using seven or more leads. Results were evaluated using the detection error rate (DER). The multi-lead detection approach allows an improvement from DER = 3:04% to DER = 1:88%. Further works are to be made in order to improve the detection performance by implementing further fusion steps.

  4. Real time QRS complex detection using DFA and regular grammar.

    Science.gov (United States)

    Hamdi, Salah; Ben Abdallah, Asma; Bedoui, Mohamed Hedi

    2017-02-28

    The sequence of Q, R, and S peaks (QRS) complex detection is a crucial procedure in electrocardiogram (ECG) processing and analysis. We propose a novel approach for QRS complex detection based on the deterministic finite automata with the addition of some constraints. This paper confirms that regular grammar is useful for extracting QRS complexes and interpreting normalized ECG signals. A QRS is assimilated to a pair of adjacent peaks which meet certain criteria of standard deviation and duration. The proposed method was applied on several kinds of ECG signals issued from the standard MIT-BIH arrhythmia database. A total of 48 signals were used. For an input signal, several parameters were determined, such as QRS durations, RR distances, and the peaks' amplitudes. σRR and σQRS parameters were added to quantify the regularity of RR distances and QRS durations, respectively. The sensitivity rate of the suggested method was 99.74% and the specificity rate was 99.86%. Moreover, the sensitivity and the specificity rates variations according to the Signal-to-Noise Ratio were performed. Regular grammar with the addition of some constraints and deterministic automata proved functional for ECG signals diagnosis. Compared to statistical methods, the use of grammar provides satisfactory and competitive results and indices that are comparable to or even better than those cited in the literature.

  5. QRS Detection Based on Improved Adaptive Threshold

    Directory of Open Access Journals (Sweden)

    Xuanyu Lu

    2018-01-01

    Full Text Available Cardiovascular disease is the first cause of death around the world. In accomplishing quick and accurate diagnosis, automatic electrocardiogram (ECG analysis algorithm plays an important role, whose first step is QRS detection. The threshold algorithm of QRS complex detection is known for its high-speed computation and minimized memory storage. In this mobile era, threshold algorithm can be easily transported into portable, wearable, and wireless ECG systems. However, the detection rate of the threshold algorithm still calls for improvement. An improved adaptive threshold algorithm for QRS detection is reported in this paper. The main steps of this algorithm are preprocessing, peak finding, and adaptive threshold QRS detecting. The detection rate is 99.41%, the sensitivity (Se is 99.72%, and the specificity (Sp is 99.69% on the MIT-BIH Arrhythmia database. A comparison is also made with two other algorithms, to prove our superiority. The suspicious abnormal area is shown at the end of the algorithm and RR-Lorenz plot drawn for doctors and cardiologists to use as aid for diagnosis.

  6. Prognostic Estimation of Advanced Heart Failure With Low Left Ventricular Ejection Fraction and Wide QRS Interval.

    Science.gov (United States)

    Oh, Changmyung; Chang, Hyuk-Jae; Sung, Ji Min; Kim, Ji Ye; Yang, Wooin; Shim, Jiyoung; Kang, Seok-Min; Ha, Jongwon; Rim, Se-Joong; Chung, Namsik

    2012-10-01

    Cardiac resynchronization therapy (CRT) has been known to improve the outcome of advanced heart failure (HF) but is still underutilized in clinical practice. We investigated the prognosis of patients with advanced HF who were suitable for CRT but were treated with conventional strategies. We also developed a risk model to predict mortality to improve the facilitation of CRT. Patients with symptomatic HF with left ventricular ejection fraction ≤35% and QRS interval >120 ms were consecutively enrolled at cardiovascular hospital. After excluding those patients who had received device therapy, 239 patients (160 males, mean 67±11 years) were eventually recruited. During a follow-up of 308±236 days, 56 (23%) patients died. Prior stroke, heart rate >90 bpm, serum Na ≤135 mEq/L, and serum creatinine ≥1.5 mg/dL were identified as independent factors using Cox proportional hazards regression. Based on the risk model, points were assigned to each of the risk factors proportional to the regression coefficient, and patients were stratified into three risk groups: low- (0), intermediate-(1-5), and high-risk (>5 points). The 2-year mortality rates of each risk group were 5, 31, and 64 percent, respectively. The C statistic of the risk model was 0.78, and the model was validated in a cohort from a different institution where the C statistic was 0.80. The mortality of patients with advanced HF who were managed conventionally was effectively stratified using a risk model. It may be useful for clinicians to be more proactive about adopting CRT to improve patient prognosis.

  7. Distribution and determinants of QRS rotation of black and white persons in the general population.

    Science.gov (United States)

    Prineas, Ronald J; Zhang, Zhu-Ming; Stevens, Cladd E; Soliman, Elsayed Z

    The prevalence and determinants of QRS transition zones are not well established. We examined the distributions of Normal, clockwise (CW) and counterclockwise (CCW)) QRS transition zones and their relations to disease, body size and demographics in 4624 black and white men and women free of cardiovascular disease and major ECG abnormalities enrolled in the NHANES-III survey. CW transition zones were least observed (6.2%) and CCW were most prevalent (60.1%) with Normal in an intermediate position (33.7%). In multivariable logistic regression analysis, the adjusted, significant predictors for CCW compared to Normal were a greater proportion of blacks and women, fewer thin people (BMI<20, thin), a greater ratio of chest depth to chest width, and an LVMass index <80g. By contrast, CW persons were older, had larger QRS/T angles, smaller ratio of chest depth to chest width, had a greater proportion of subjects with low voltage QRS, more pulmonary disease, a greater proportion with high heart rates, shorter QRS duration and were more obese (BMI≥30). Normal rather than being the most prevalent transition zone was intermediate in frequency between the most frequently encountered CCW and the least frequently encountered transition zone CW. Differences in the predictors of CW and CCW exist. This requires further investigation to examine how far these differences explain the differences in the published prognostic differences between CW and CCW. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. [Basic mechanisms of QRS voltage changes on ECG of healthy subjects during the exercise test].

    Science.gov (United States)

    Saltykova, M M

    2015-01-01

    Electrocardiography is the most commonly used technique for detection stress-induced myocardial ischemia. However, the sensitivity of ECG-criteria is not high. One of the major problem is the difficulty in differentiating ECG changes caused by various factors. The aim of this study was to evaluate the dependence of the QRS voltage changes during exercise on parameters of central hemodynamics, gender particularities and to reveal mechanisms causing these changes. To eliminate the effect of changes in cardiomyocytes transmembrane potentials under the influence of the neurotransmitters of the autonomic nervous system during stepwise increasing exercises and/or due to a lack of ATP results from inadequate myocardial blood flow only healthy subjects not older than 35 years were included in the study (7 men and 7 women) and only periods of ventricular depolarization (QRS complex on the ECG) were included in the analysis. We compared the changes of QRS waves during exercise sessions with two upper and one lower limbs in both men and women. The exercise load was twice bigger in exercise with one leg relative to exercise with two arms. Responses of heart rate and systolic arterial pressure were similar. Amplitude of S-wave in left chest leads significantly increased in both sessions without significant difference between augmentations in the sessions and in groups of men and women. Significant relationship between the S wave augmentation and the peak systolic arterial pressure were revealed. Furthermore, the QRS changes during the exercise with vertical and a horizontal torso position were compared to assess the impact of diastolic arterial pressure and displacement of the diaphragm and heart rotation due to increase of abdominal pressure during the last steps of exercise. The obtained results allow us to exclude the impact of the heart position and size changes, as well as the exercise load on S-wave changes and make a conclusion about the dependence of this parameter on

  9. Efeitos agudos de levosimendana e dobutamina na duração do QRS em Pacientes com insuficiência cardíaca Efectos agudos de levosimendana y dobutamina en la duración del QRS en pacientes con insuficiencia cardíaca Acute effects of levosimendan and dobutamine on QRS duration in patients with heart failure

    Directory of Open Access Journals (Sweden)

    Osman Can Yontar

    2010-12-01

    calcio, de forma de no causar sobrecarga de calcio y arritmias relacionadas. En pacientes con insuficiencia cardíaca (IC, la duración prolongada del QRS está asociada a un aumento en el riesgo de mortalidad y muerte súbita cardíaca. Cambios estructurales en el ventrículo izquierdo pueden llevar a la contracción asíncrona, causando atraso de conducción y un QRS prolongado en el ECG de superficie. OBJETIVO: EL objetivo del presente estudio fue comparar los efectos agudos de levosimendana y dobutamina en la duración del QRS en pacientes con IC grave y ritmo sinusal. MÉTODOS: 60 pacientes consecutivos con IC isquémica fueron incluidos en el estudio y randomizados en dos grupos para infusión de levosimendana (n=37 o dobutamina (n=23. 67,2 % eran hombres; la media de la edad era 66,4±9,2 para todos los pacientes. La duración basal del QRS en los grupos levosimendana y dobutamina fue 120,44±23,82 vs. 116,59±13,80 respectivamente. La fracción de eyección del ventrículo izquierdo (FEVI estaba disminuida en ambos grupos (23,15±8,3 vs. 24,56±7,5. RESULTADOS: En el grupo levosimendana, la duración del QRS disminuyó del valor basal para 116,47±24,56 ms (p=0,006, en cuanto no hubo diferencia significativa en el grupo dobutamina (p=0,605. Ambos medicamentos causaron un aumento en la FEVI, pero este fue significativo apenas en el grupo levosimendana (27,95±8,9 p=0,003 vs. 26,67±7,6, p=0,315. CONCLUSIÓN: El estudio sugiere que la administración de levosimendana, pero no de dobutamina, acorta la duración del QRS en el ECG de superficie, posiblemente por causar una contracción colectiva en las fibras del músculo del ventrículo izquierdo. La base molecular de ese efecto aun precisa ser aclarada.BACKGROUND: Levosimendan is a novel inotropic agent that enhances cardiac contractility without increasing cellular calcium intake, so that it is not supposed to cause intracellular calcium overload and related arrhythmias. In patients with heart failure, prolonged

  10. Clinical significance of fragmented QRS complexes or J waves in patients with idiopathic ventricular arrhythmias.

    Science.gov (United States)

    Seong, Choong Sil; Gwag, Hye Bin; Hwang, Jin Kyung; Park, Seung Jung; Park, Kyoung-Min; Kim, June Soo; On, Young Keun

    2018-01-01

    Idiopathic ventricular fibrillation (IVF) can cause sudden cardiac death. Previous studies have reported that J waves and fragmented QRS complexes (f-QRS) are arrhythmogenic markers and predictors of cardiac events. We evaluated the prevalence and clinical significance of J waves and f-QRS in patients with IVF. We studied 81 patients who received an implantable cardioverter defibrillator (ICD) due to IVF between October 1999 and June 2015. We assessed the prevalence of J waves and f-QRS using electrocardiograms (ECGs). Patients were classified into three groups: J wave group (n = 35), f-QRS group (n = 20), or normal ECG group (n = 26). The control group included 81 subjects without heart disease who were matched for age, sex, and race. We compared syncope, sudden cardiac arrest, and appropriate ICD shock between the three groups. The follow-up duration was 4.1 years. J waves and f-QRS were more frequent in patients with IVF than in control subjects (43.2%, 21% vs. 24.7%, 19.7%, P J wave and f-QRS versus the normal ECG group revealed that the combined group had a higher frequency of clinical cardiac events than the normal ECG group (47.3% vs. 11.5%, respectively, P = 0.009). Patients with IVF had higher prevalence of f-QRS or J waves. And patients with f-QRS or J waves were at higher risk of recurrent ventricular fibrillation.

  11. Onset of decreased heart work is correlated with increased heart rate and shortened QT interval in high-carbohydrate fed overweight rats.

    Science.gov (United States)

    Durak, Aysegul; Olgar, Yusuf; Tuncay, Erkan; Karaomerlioglu, Irem; Kayki Mutlu, Gizem; Arioglu Inan, Ebru; Altan, Vecdi Melih; Turan, Belma

    2017-11-01

    Mechanical activity of the heart is adversely affected in metabolic syndrome (MetS) characterized by increased body mass and marked insulin resistance. Herein, we examined the effects of high carbohydrate intake on cardiac function abnormalities by evaluating in situ heart work, heart rate, and electrocardiograms (ECGs) in rats. MetS was induced in male Wistar rats by adding 32% sucrose to drinking water for 22-24 weeks and was confirmed by insulin resistance, increased body weight, increased blood glucose and serum insulin, and increased systolic and diastolic blood pressures in addition to significant loss of left ventricular integrity and increased connective tissue around myofibrils. Analysis of in situ ECG recordings showed a markedly shortened QT interval and decreased QRS amplitude with increased heart rate. We also observed increased oxidative stress and decreased antioxidant defense characterized by decreases in serum total thiol level and attenuated paraoxonase and arylesterase activities. Our data indicate that increased heart rate and a shortened QT interval concomitant with higher left ventricular developed pressure in response to β-adrenoreceptor stimulation as a result of less cyclic AMP release could be regarded as a natural compensation mechanism in overweight rats with MetS. In addition to the persistent insulin resistance and obesity associated with MetS, one should consider the decreased heart work, increased heart rate, and shortened QT interval associated with high carbohydrate intake, which may have more deleterious effects on the mammalian heart.

  12. Determination of heart rate variability with an electronic stethoscope.

    Science.gov (United States)

    Kamran, Haroon; Naggar, Isaac; Oniyuke, Francisca; Palomeque, Mercy; Chokshi, Priya; Salciccioli, Louis; Stewart, Mark; Lazar, Jason M

    2013-02-01

    Heart rate variability (HRV) is widely used to characterize cardiac autonomic function by measuring beat-to-beat alterations in heart rate. Decreased HRV has been found predictive of worse cardiovascular (CV) outcomes. HRV is determined from time intervals between QRS complexes recorded by electrocardiography (ECG) for several minutes to 24 h. Although cardiac auscultation with a stethoscope is performed routinely on patients, the human ear cannot detect heart sound time intervals. The electronic stethoscope digitally processes heart sounds, from which cardiac time intervals can be obtained. Accordingly, the objective of this study was to determine the feasibility of obtaining HRV from electronically recorded heart sounds. We prospectively studied 50 subjects with and without CV risk factors/disease and simultaneously recorded single lead ECG and heart sounds for 2 min. Time and frequency measures of HRV were calculated from R-R and S1-S1 intervals and were compared using intra-class correlation coefficients (ICC). The majority of the indices were strongly correlated (ICC 0.73-1.0), while the remaining indices were moderately correlated (ICC 0.56-0.63). In conclusion, we found HRV measures determined from S1-S1 are in agreement with those determined by single lead ECG, and we demonstrate and discuss differences in the measures in detail. In addition to characterizing cardiac murmurs and time intervals, the electronic stethoscope holds promise as a convenient low-cost tool to determine HRV in the hospital and outpatient settings as a practical extension of the physical examination.

  13. Automatic QRS complex detection using two-level convolutional neural network.

    Science.gov (United States)

    Xiang, Yande; Lin, Zhitao; Meng, Jianyi

    2018-01-29

    The QRS complex is the most noticeable feature in the electrocardiogram (ECG) signal, therefore, its detection is critical for ECG signal analysis. The existing detection methods largely depend on hand-crafted manual features and parameters, which may introduce significant computational complexity, especially in the transform domains. In addition, fixed features and parameters are not suitable for detecting various kinds of QRS complexes under different circumstances. In this study, based on 1-D convolutional neural network (CNN), an accurate method for QRS complex detection is proposed. The CNN consists of object-level and part-level CNNs for extracting different grained ECG morphological features automatically. All the extracted morphological features are used by multi-layer perceptron (MLP) for QRS complex detection. Additionally, a simple ECG signal preprocessing technique which only contains difference operation in temporal domain is adopted. Based on the MIT-BIH arrhythmia (MIT-BIH-AR) database, the proposed detection method achieves overall sensitivity Sen = 99.77%, positive predictivity rate PPR = 99.91%, and detection error rate DER = 0.32%. In addition, the performance variation is performed according to different signal-to-noise ratio (SNR) values. An automatic QRS detection method using two-level 1-D CNN and simple signal preprocessing technique is proposed for QRS complex detection. Compared with the state-of-the-art QRS complex detection approaches, experimental results show that the proposed method acquires comparable accuracy.

  14. Effect of study design on the reported effect of cardiac resynchronization therapy (CRT) on quantitative physiological measures: stratified meta-analysis in narrow-QRS heart failure and implications for planning future studies.

    Science.gov (United States)

    Jabbour, Richard J; Shun-Shin, Matthew J; Finegold, Judith A; Afzal Sohaib, S M; Cook, Christopher; Nijjer, Sukhjinder S; Whinnett, Zachary I; Manisty, Charlotte H; Brugada, Josep; Francis, Darrel P

    2015-01-06

    Biventricular pacing (CRT) shows clear benefits in heart failure with wide QRS, but results in narrow QRS have appeared conflicting. We tested the hypothesis that study design might have influenced findings. We identified all reports of CRT-P/D therapy in subjects with narrow QRS reporting effects on continuous physiological variables. Twelve studies (2074 patients) met these criteria. Studies were stratified by presence of bias-resistance steps: the presence of a randomized control arm over a single arm, and blinded outcome measurement. Change in each endpoint was quantified using a standardized effect size (Cohen's d). We conducted separate meta-analyses for each variable in turn, stratified by trial quality. In non-randomized, non-blinded studies, the majority of variables (10 of 12, 83%) showed significant improvement, ranging from a standardized mean effect size of +1.57 (95%CI +0.43 to +2.7) for ejection fraction to +2.87 (+1.78 to +3.95) for NYHA class. In the randomized, non-blinded study, only 3 out of 6 variables (50%) showed improvement. For the randomized blinded studies, 0 out of 9 variables (0%) showed benefit, ranging from -0.04 (-0.31 to +0.22) for ejection fraction to -0.1 (-0.73 to +0.53) for 6-minute walk test. Differences in degrees of resistance to bias, rather than choice of endpoint, explain the variation between studies of CRT in narrow-QRS heart failure addressing physiological variables. When bias-resistance features are implemented, it becomes clear that these patients do not improve in any tested physiological variable. Guidance from studies without careful planning to resist bias may be far less useful than commonly perceived. © 2015 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  15. The Shortest QRS Duration of an Electrocardiogram Might Be an Optimal Electrocardiographic Predictor for Response to Cardiac Resynchronization Therapy.

    Science.gov (United States)

    Chen, Jan-Yow; Lin, Kuo-Hung; Chang, Kuan-Cheng; Chou, Che-Yi

    2017-08-03

    QRS duration has been associated with the response to cardiac resynchronization therapy (CRT). However, the methods for defining QRS duration to predict the outcome of CRT have discrepancies in previous reports. The aim of this study was to determine an optimal measurement of QRS duration to predict the response to CRT.Sixty-one patients who received CRT were analyzed. All patients had class III-IV heart failure, left ventricular ejection fraction not more than 35%, and complete left bundle branch block. The shortest, longest, and average QRS durations from the 12 leads of each electrocardiogram (ECG) were measured. The responses to CRT were determined using the changes in echocardiography after 6 months. Thirty-five (57.4%) patients were responders and 26 (42.6%) patients were non-responders. The pre-procedure shortest, average, and longest QRS durations and the QRS shortening (ΔQRS) of the shortest QRS duration were significantly associated with the response to CRT in a univariate logistic regression analysis (P = 0.002, P = 0.03, P = 0.04 and P = 0.04, respectively). Based on the measurement of the area under curve of the receiver operating characteristic curve, only the pre-procedure shortest QRS duration and the ΔQRS of the shortest QRS duration showed significant discrimination for the response to CRT (P = 0.002 and P = 0.038, respectively). Multivariable logistic regression showed the pre-procedure shortest QRS duration is an independent predictor for the response to CRT.The shortest QRS duration from the 12 leads of the electrocardiogram might be an optimal measurement to predict the response to CRT.

  16. Prognostic importance of left ventricular mechanical dyssynchrony in heart failure with preserved ejection fraction

    DEFF Research Database (Denmark)

    Biering-Sørensen, Tor; Shah, Sanjiv J; Anand, Inder

    2017-01-01

    AIMS: Left ventricular mechanical dyssynchrony has been described in heart failure with preserved ejection fraction (HFpEF), but its prognostic significance is not known. METHODS AND RESULTS: Of 3445 patients with HFpEF enrolled in the Treatment of Preserved Cardiac Function Heart Failure...... models assessed the association of dyssynchrony with the composite outcome of cardiovascular death or heart failure hospitalization. Mean age was 70 ± 10 years, LVEF was 60 ± 8%, and QRS duration was 101 ± 27 ms. Worse dyssynchrony, reflected in SD T2P LS, was associated with wider QRS, prior myocardial...... with the composite outcome in unadjusted analysis [hazard ratio (HR) 1.04, 95% confidence interval (CI) 1.01-1.07; P = 0.021, per 10 ms increase], but not after adjusting for clinical characteristics, or after further adjustment for LVEF, AF, NYHA class, stroke, heart rate, creatinine, haematocrit, and QRS duration...

  17. Value of the New Spline QTc Formula in Adjusting for Pacing-Induced Changes in Heart Rate

    Directory of Open Access Journals (Sweden)

    Hirmand Nouraei

    2018-01-01

    Full Text Available Aims. To determine whether a new QTc calculation based on a Spline fit model derived and validated from a large population remained stable in the same individual across a range of heart rates (HRs. Second, to determine whether this formula incorporating QRS duration can be of value in QT measurement, compared to direct measurement of the JT interval, during ventricular pacing. Methods. Individuals (N=30; 14 males aged 51.9 ± 14.3 years were paced with decremental atrial followed by decremental ventricular pacing. Results. The new QTc changed minimally with shorter RR intervals, poorly fit even a linear relationship, and did not fit a second-order polynomial. In contrast, the Bazett formula (QTcBZT showed a steep and marked increase in QTc with shorter RR intervals. For atrial pacing data, QTcBZT was fit best by a second-order polynomial and demonstrated a dramatic increase in QTc with progressively shorter RR intervals. For ventricular pacing, the new QTc minus QRS duration did not meaningfully change with HR in contrast to the HR dependency of QTcBZT and JT interval. Conclusion. The new QT correction formula is minimally impacted by HR acceleration induced by atrial or ventricular pacing. The Spline QTc minus QRS duration is an excellent method to estimate QTc in ventricular paced complexes.

  18. Noninvasive fetal QRS detection using an echo state network and dynamic programming.

    Science.gov (United States)

    Lukoševičius, Mantas; Marozas, Vaidotas

    2014-08-01

    We address a classical fetal QRS detection problem from abdominal ECG recordings with a data-driven statistical machine learning approach. Our goal is to have a powerful, yet conceptually clean, solution. There are two novel key components at the heart of our approach: an echo state recurrent neural network that is trained to indicate fetal QRS complexes, and several increasingly sophisticated versions of statistics-based dynamic programming algorithms, which are derived from and rooted in probability theory. We also employ a standard technique for preprocessing and removing maternal ECG complexes from the signals, but do not take this as the main focus of this work. The proposed approach is quite generic and can be extended to other types of signals and annotations. Open-source code is provided.

  19. ECG-derived spatial QRS-T angle is associated with ICD implantation, mortality and heart failure admissions in patients with LV systolic dysfunction.

    Directory of Open Access Journals (Sweden)

    Sarah Gleeson

    Full Text Available Increased spatial QRS-T angle has been shown to predict appropriate implantable cardioverter defibrilIator (ICD therapy in patients with left ventricular systolic dysfunction (LVSD. We performed a retrospective cohort study in patients with left ventricular ejection fraction (LVEF 31-40% to assess the relationship between the spatial QRS-T angle and other advanced ECG (A-ECG as well as echocardiographic metadata, with all-cause mortality or ICD implantation for secondary prevention.534 patients ≤75 years of age with LVEF 31-40% were identified through an echocardiography reporting database. Digital 12-lead ECGs were retrospectively matched to 295 of these patients, for whom echocardiographic and A-ECG metadata were then generated. Data mining was applied to discover novel ECG and echocardiographic markers of risk. Machine learning was used to develop a model to predict possible outcomes.49 patients (17% had events, defined as either mortality (n = 16 or ICD implantation for secondary prevention (n = 33. 72 parameters (58 A-ECG, 14 echocardiographic were univariately different (p110° had an adjusted HR of 3.4 (95% CI 1.6 to 7.4 for secondary ICD implantation or all-cause death and adjusted HR of 4.1 (95% CI 1.2 to 13.9 for future heart failure admission. There was a loss of complexity between A-ECG and echocardiographic variables with an increasing degree of disease.Spatial QRS-T angle >110° was strongly associated with arrhythmic events and all-cause death. Deep analysis of global ECG and echocardiographic metadata revealed underlying relationships, which otherwise would not have been appreciated. Delivered at scale such techniques may prove useful in clinical decision making in the future.

  20. Distinctive Left Ventricular Activations Associated With ECG Pattern in Heart Failure Patients.

    Science.gov (United States)

    Derval, Nicolas; Duchateau, Josselin; Mahida, Saagar; Eschalier, Romain; Sacher, Frederic; Lumens, Joost; Cochet, Hubert; Denis, Arnaud; Pillois, Xavier; Yamashita, Seigo; Komatsu, Yuki; Ploux, Sylvain; Amraoui, Sana; Zemmoura, Adlane; Ritter, Philippe; Hocini, Mélèze; Haissaguerre, Michel; Jaïs, Pierre; Bordachar, Pierre

    2017-06-01

    In contrast to patients with left bundle branch block (LBBB), heart failure patients with narrow QRS and nonspecific intraventricular conduction delay (NICD) display a relatively limited response to cardiac resynchronization therapy. We sought to compare left ventricular (LV) activation patterns in heart failure patients with narrow QRS and NICD to patients with LBBB using high-density electroanatomic activation maps. Fifty-two heart failure patients (narrow QRS [n=18], LBBB [n=11], NICD [n=23]) underwent 3-dimensional electroanatomic mapping with a high density of mapping points (387±349 LV). Adjunctive scar imaging was available in 37 (71%) patients and was analyzed in relation to activation maps. LBBB patients typically demonstrated (1) a single LV breakthrough at the septum (38±15 ms post-QRS onset); (2) prolonged right-to-left transseptal activation with absence of direct LV Purkinje activity; (3) homogeneous propagation within the LV cavity; and (4) latest activation at the basal lateral LV. In comparison, both NICD and narrow QRS patients demonstrated (1) multiple LV breakthroughs along the posterior or anterior fascicles: narrow QRS versus LBBB, 5±2 versus 1±1; P =0.0004; NICD versus LBBB, 4±2 versus 1±1; P =0.001); (2) evidence of early/pre-QRS LV electrograms with Purkinje potentials; (3) rapid propagation in narrow QRS patients and more heterogeneous propagation in NICD patients; and (4) presence of limited areas of late activation associated with LV scar with high interindividual heterogeneity. In contrast to LBBB patients, narrow QRS and NICD patients are characterized by distinct mechanisms of LV activation, which may predict poor response to cardiac resynchronization therapy. © 2017 American Heart Association, Inc.

  1. Clinical and electrophysiological characteristics of patients with paroxysmal intra-His block with narrow QRS complexes.

    Science.gov (United States)

    Ragupathi, Loheetha; Johnson, Drew; Greenspon, Arnold; Frisch, Daniel; Ho, Reginald T; Pavri, Behzad B

    2018-04-18

    Atrioventricular (AV) block is usually due to infranodal disease and associated with a wide QRS complex; such patients often progress to complete AV block and pacemaker dependency. Uncommonly, infranodal AV block can occur within the His bundle with a narrow QRS complex. The aims of this study were to define clinical/echocardiographic characteristics of patients with AV block within the His bundle and report progression to pacemaker dependency. We retrospectively identified patients with narrow QRS complexes and documented intra-His delay or block at electrophysiology study (group A) or with electrocardiogram-documented Mobitz II AV block/paroxysmal AV block (group B). Clinical, electrophysiological, and echocardiographic variables at presentation and pacemaker parameters at the last follow-up visit were evaluated. Twenty-seven patients (19 women) were identified (mean age 64 ± 13 years; range, 38-85 years). Four patients who had block with narrow QRS complexes rarely progress to pacemaker dependency and require infrequent pacing. This entity is more common in women, with a higher prevalence of aortic and/or mitral annular calcification. If confirmed by additional studies, single-chamber pacemaker may be sufficient. Copyright © 2018 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  2. Utility of heart rate turbulence and T-Wave alternans to assess risk for Re-admission and cardiac death in hospitalized heart failure patients.

    Science.gov (United States)

    Yamada, Shinya; Yoshihisa, Akiomi; Sato, Yu; Sato, Takamasa; Kamioka, Masashi; Kaneshiro, Takashi; Oikawa, Masayoshi; Kobayashi, Atsushi; Suzuki, Hitoshi; Ishida, Takafumi; Takeishi, Yasuchika

    2018-05-18

    Heart failure (HF) patients have a higher risk of recurrent HF and cardiac death, and electrical remodeling is considered to be an important factor for HF progression. The present study aimed to validate the utility of electrocardiogram and Holter monitoring for the risk stratification of HF patients. Our study comprised 215 patients (144 males, mean age 62 years) who had been hospitalized due to acute decompensated HF. Electrocardiogram (QRS duration and QTc interval) and 24-hour Holter monitoring (heart rate variability, heart rate turbulence and T-wave alternans [TWA]) were performed in stable condition before discharge. The clinical characteristics and outcomes were then investigated. During a median follow-up period of 2.7 years, there were 83 (38.6%) cardiac events (re-hospitalization due to worsening HF [n = 51] or cardiac death [n = 32]). The patients with cardiac events had a lower turbulence slope (TS) and higher TWA compared to those without cardiac events (TS, 3.0±5.5 ms/RR vs. 5.3±5.6 ms/RR, P = 0.001; TWA, 66.1±19.6 μV vs. 54.7±15.1 μV, P < 0.001). Univariable analysis showed that TS, TWA, QRS duration, and QTc interval were associated with cardiac events (P = 0.004, P < 0.001, P = 0.037 and P = 0.024, respectively), while the multivariable analysis after the adjustment of multiple confounders showed that TS and TWA were independent predictive factors of cardiac events with a hazard ratio of 0.936 and 1.015 (95% confidence interval [CI]: 0.860-0.974, P = 0.006; and 95% CI: 1.003-1.027, p = 0.016), respectively. The measurement of TS and TWA is useful for assessing risk for re-hospitalization and cardiac death in HF patients. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  3. Heart rate index

    DEFF Research Database (Denmark)

    Haedersdal, C; Pedersen, F H; Svendsen, J H

    1992-01-01

    after the myocardial infarction. A significant correlation (Spearman's correlation coefficient rs, p less than 0.05) was found between LVEF at rest and the following variables assessed at exercise test: 1) the heart rate at rest, 2) rise in heart rate, 3) ratio between maximal heart rate and heart rate...... at rest, 4) rise in systolic blood pressure, 5) rate pressure product at rest, 6) rise in rate pressure product, 7) ratio (rHR) between maximal rate pressure product and rate pressure product at rest, 8) total exercise time. The heart rate was corrected for effects caused by age (heart index (HR...

  4. Noninvasive fetal QRS detection using an echo state network and dynamic programming

    International Nuclear Information System (INIS)

    Lukoševičius, Mantas; Marozas, Vaidotas

    2014-01-01

    We address a classical fetal QRS detection problem from abdominal ECG recordings with a data-driven statistical machine learning approach. Our goal is to have a powerful, yet conceptually clean, solution. There are two novel key components at the heart of our approach: an echo state recurrent neural network that is trained to indicate fetal QRS complexes, and several increasingly sophisticated versions of statistics-based dynamic programming algorithms, which are derived from and rooted in probability theory. We also employ a standard technique for preprocessing and removing maternal ECG complexes from the signals, but do not take this as the main focus of this work. The proposed approach is quite generic and can be extended to other types of signals and annotations. Open-source code is provided. (paper)

  5. Interaction of Left Ventricular Size and Sex on Outcome of Cardiac Resynchronization Therapy Among Patients With a Narrow QRS Duration in the EchoCRT Trial

    DEFF Research Database (Denmark)

    Varma, Niraj; Sogaard, Peter; Bax, Jeroen J

    2018-01-01

    BACKGROUND: Longer QRS duration (QRSd) improves, but increased left ventricular (LV) end-diastolic volume (LVEDV) reduces, efficacy of cardiac resynchronization therapy (CRT). QRSd/LVEDV ratios differ between sexes. We hypothesized that in the EchoCRT (Echocardiography Guided Cardiac Resynchroniz......BACKGROUND: Longer QRS duration (QRSd) improves, but increased left ventricular (LV) end-diastolic volume (LVEDV) reduces, efficacy of cardiac resynchronization therapy (CRT). QRSd/LVEDV ratios differ between sexes. We hypothesized that in the EchoCRT (Echocardiography Guided Cardiac...... Resynchronization Therapy) trial enrolling patients with heart failure with QRSd New York Heart Association class III, QRSd

  6. Noise-tolerant instantaneous heart rate and R-peak detection using short-term autocorrelation for wearable healthcare systems.

    Science.gov (United States)

    Fujii, Takahide; Nakano, Masanao; Yamashita, Ken; Konishi, Toshihiro; Izumi, Shintaro; Kawaguchi, Hiroshi; Yoshimoto, Masahiko

    2013-01-01

    This paper describes a robust method of Instantaneous Heart Rate (IHR) and R-peak detection from noisy electrocardiogram (ECG) signals. Generally, the IHR is calculated from the R-wave interval. Then, the R-waves are extracted from the ECG using a threshold. However, in wearable bio-signal monitoring systems, noise increases the incidence of misdetection and false detection of R-peaks. To prevent incorrect detection, we introduce a short-term autocorrelation (STAC) technique and a small-window autocorrelation (SWAC) technique, which leverages the similarity of QRS complex waveforms. Simulation results show that the proposed method improves the noise tolerance of R-peak detection.

  7. QRS Complex Enlargement as a Predictor of Ventricular Arrhythmias in Patients Affected by Surgically Treated Tetralogy of Fallot: A Comprehensive Literature Review and Historical Overview

    Science.gov (United States)

    Bassareo, Pier Paolo; Mercuro, Giuseppe

    2013-01-01

    Tetralogy of Fallot (TOF) is a congenital heart disease frequently treated by surgical repair to relieve symptoms and improve survival. However, despite the performing of an optimal surgical repair, TOF patients are at times characterized by a poor long-term survival rate, likely due to cardiac causes such as ventricular arrhythmias, with subsequent sudden death. In the 80s it was irrefutably demonstrated that QRS prolongation ≥180 msec at basal electrocardiogram is a strong predictor for refining risk stratification for ventricular tachycardia in these patients. The aim of this research was to undertake a review of all studies conducted to assess the impact of QRS duration on the development of life-threatening ventricular arrhythmias in repaired TOF subjects. PMID:23509638

  8. Identification of the QRS Complex in the ECG

    Directory of Open Access Journals (Sweden)

    Martin Paralič

    2016-12-01

    Full Text Available The cardiovascular heart diseases are one of the most common causes of leading to death of man. Unfortunately, the symptoms vary and the most common reason for critical delays in medical treatment is lack of early warning and patient unawareness. In this paper, we present a development of the mobile application for Electrocardiogram measurements based on communication with a smart clothing using Bluetooth. The objectives of the application are a wireless data collection and analysis of ECG signal. The analysis is aimed for precise detection of QRS complex parameters plus detection of P-wave and T-wave. Measurement and evaluation of multiple PQRST parameters in a series allows detection of anomalies which leads to different heart diseases. Early warning system can help to make preventive actions to avoid severe heart disease. The recorded data are exported to format of the MIT/BIH arrhythmia database to be compatible with the professional medical software. This program will be devoted to the purposes of research and home healthcare instead of clinical diagnosis.

  9. Mobile/android application for QRS detection using zero cross method

    Science.gov (United States)

    Rizqyawan, M. I.; Simbolon, A. I.; Suhendra, M. A.; Amri, M. F.; Kusumandari, D. E.

    2018-03-01

    In automatic ECG signal processing, one of the main topics of research is QRS complex detection. Detecting correct QRS complex or R peak is important since it is used to measure several other ECG metrics. One of the robust methods for QRS detection is Zero Cross method. This method uses an addition of high-frequency signal and zero crossing count to detect QRS complex which has a low-frequency oscillation. This paper presents an application of QRS detection using Zero Cross algorithm in the Android-based system. The performance of the algorithm in the mobile environment is measured. The result shows that this method is suitable for real-time QRS detection in a mobile application.

  10. Fetal QRS extraction from abdominal recordings via model-based signal processing and intelligent signal merging

    International Nuclear Information System (INIS)

    Haghpanahi, Masoumeh; Borkholder, David A

    2014-01-01

    Noninvasive fetal ECG (fECG) monitoring has potential applications in diagnosing congenital heart diseases in a timely manner and assisting clinicians to make more appropriate decisions during labor. However, despite advances in signal processing and machine learning techniques, the analysis of fECG signals has still remained in its preliminary stages. In this work, we describe an algorithm to automatically locate QRS complexes in noninvasive fECG signals obtained from a set of four electrodes placed on the mother’s abdomen. The algorithm is based on an iterative decomposition of the maternal and fetal subspaces and filtering of the maternal ECG (mECG) components from the fECG recordings. Once the maternal components are removed, a novel merging technique is applied to merge the signals and detect the fetal QRS (fQRS) complexes. The algorithm was trained and tested on the fECG datasets provided by the PhysioNet/CinC challenge 2013. The final results indicate that the algorithm is able to detect fetal peaks for a variety of signals with different morphologies and strength levels encountered in clinical practice. (paper)

  11. Automatic classification of transient ischaemic and transient non-ischaemic heart-rate related ST segment deviation episodes in ambulatory ECG records

    International Nuclear Information System (INIS)

    Faganeli, J; Jager, F

    2010-01-01

    In ambulatory ECG records, besides transient ischaemic ST segment deviation episodes, there are also transient non-ischaemic heart-rate related ST segment deviation episodes present, which appear only due to a change in heart rate and thus complicate automatic detection of true ischaemic episodes. The goal of this work was to automatically classify these two types of episodes. The tested features to classify the ST segment deviation episodes were changes of heart rate, changes of the Mahalanobis distance of the first five Karhunen–Loève transform (KLT) coefficients of the QRS complex, changes of time-domain morphologic parameters of the ST segment and changes of the Legendre orthonormal polynomial coefficients of the ST segment. We chose Legendre basis functions because they best fit typical shapes of the ST segment morphology, thus allowing direct insight into the ST segment morphology changes through the feature space. The classification was performed with the help of decision trees. We tested the classification method using all records of the Long-Term ST Database on all ischaemic and all non-ischaemic heart-rate related deviation episodes according to annotation protocol B. In order to predict the real-world performance of the classification we used second-order aggregate statistics, gross and average statistics, and the bootstrap method. We obtained the best performance when we combined the heart-rate features, the Mahalanobis distance and the Legendre orthonormal polynomial coefficient features, with average sensitivity of 98.1% and average specificity of 85.2%

  12. Cardiac resynchronization induces major structural and functional reverse remodeling in patients with New York Heart Association class I/II heart failure

    DEFF Research Database (Denmark)

    St John Sutton, Martin; Ghio, Stefano; Plappert, Ted

    2009-01-01

    BACKGROUND: Cardiac resynchronization therapy (CRT) improves LV structure, function, and clinical outcomes in New York Heart Association class III/IV heart failure with prolonged QRS. It is not known whether patients with New York Heart Association class I/II systolic heart failure exhibit left...... ventricular (LV) reverse remodeling with CRT or whether reverse remodeling is modified by the cause of heart failure. METHODS AND RESULTS: Six hundred ten patients with New York Heart Association class I/II heart failure, QRS duration > or =120 ms, LV end-diastolic dimension > or =55 mm, and LV ejection...... reduction in LV end-diastolic and end-systolic volume indexes and a 3-fold greater increase in LV ejection fraction in patients with nonischemic causes of heart failure. CONCLUSIONS: CRT in patients with New York Heart Association I/II resulted in major structural and functional reverse remodeling at 1 year...

  13. Counterclockwise and Clockwise Rotation of QRS Transitional Zone: Prospective Correlates of Change and Time-Varying Associations With Cardiovascular Outcomes.

    Science.gov (United States)

    Patel, Siddharth; Kwak, Lucia; Agarwal, Sunil K; Tereshchenko, Larisa G; Coresh, Josef; Soliman, Elsayed Z; Matsushita, Kunihiro

    2017-11-03

    A few studies have recently reported clockwise and counterclockwise rotations of QRS transition zone as predictors of mortality. However, their prospective correlates and associations with individual cardiovascular disease (CVD) outcomes are yet to be investigated. Among 13 567 ARIC (Atherosclerosis Risk in Communities) study participants aged 45 to 64 years, we studied key correlates of changes in the status of clockwise and counterclockwise rotation over time as well as the association of rotation status with incidence of coronary heart disease (2408 events), heart failure (2196 events), stroke (991 events), composite CVD (4124 events), 898 CVD deaths, and 3469 non-CVD deaths over 23 years of follow-up. At baseline, counterclockwise rotation was most prevalent (52.9%), followed by no (40.5%) and clockwise (6.6%) rotation. Of patients with no rotation, 57.9% experienced counterclockwise or clockwise rotation during follow-up, with diabetes mellitus and black race significantly predicting clockwise and counterclockwise conversion, respectively. Clockwise rotation was significantly associated with higher risk of heart failure (hazard ratio, 1.20; 95% confidence interval [CI], 1.02-1.41) and non-CVD death (hazard ratio, 1.28; 95% CI, 1.12-1.46) after adjusting for potential confounders including other ECG parameters. On the contrary, counterclockwise rotation was significantly related to lower risk of composite CVD (hazard ratio, 0.93; 95% CI, 0.87-0.99]), CVD mortality (hazard ratio, 0.76; 95% CI, 0.65-0.88), and non-CVD deaths (hazard ratio, 0.92; 95% CI, 0.85-0.99 [borderline significance with heart failure]). Counterclockwise rotation, the most prevalent QRS transition zone pattern, demonstrated the lowest risk of CVD and mortality, whereas clockwise rotation was associated with the highest risk of heart failure and non-CVD mortality. These results have implications on how to interpret QRS transition zone rotation when ECG was recorded. © 2017 The Authors

  14. 2D.03: IMPROVING DIAGNOSTIC STRATEGY IN PATIENTS WITH LONG-STANDING HYPERTENSION, CHEST PAIN AND NORMAL RESTING ECG: VALUE OF THE EXERCISE HIGH-FREQUENCY QRS VERSUS ST-SEGMENT ANALYSIS.

    Science.gov (United States)

    Conti, A; Bianchi, S; Grifoni, C; Trausi, F; Angeli, E; Paolini, D; Catarzi, S; Perrotta, M E; Covelli, A; Renzi, N; Bertolini, P; Mazzucchelli, M

    2015-06-01

    The novel exercise computer-assisted high-frequency QRS-analysis (ex-HF/QRS) has demonstrated improved sensitivity and specificity over the conventional exercise-ST/ECG-segment-analysis (ex-ST/ECG) in the detection of myocardial ischemia. The aim of the present study was to test the implementation in diagnostic value of the ex-HF/QRS in patient with hypertension and chest pain (CP) versus the conventional ex-ST/ECG anlysis alone. Patients with long-standing hypertension, CP, normal ECG, troponin and echocardiography were enrolled. All patients underwent the ex-ST/ECG and ex-HF/QRS. A decrease >/=50% of the signal of ex-HF/QRS intensity recorded in two contiguous leads, at least, was considered as index of ischaemia, as ST-segment depression >/=2 mm or >/=1 mm and CP on ex-ST/ECG. Exclusion criteria were QRS duration >/=120 msec and inability to exercise. The end-point was the composite of coronary stenosis >50% or acute coronary syndrome, revascularization, cardiovascular death at 3-month follow-up. Six-hundred thirty-one patients were enrolled (age 61+/-15 y). The percentage of age-adjusted maximal predicted heart rate was 88+/-10 beat-per-minute and the maximal systolic blood pressure was 169+/-22 mmHg. Twenty-seven patients achieved the end-point. On multivariate analysis, both the ex-ST/ECG and ex-HF/QRS were predictors of the end-point. The ex-HF/QRS showed higher sensitivity (88% vs 50%; p = 0.003), lower specificity (77% vs 97%; p = 0.245) and comparable negative predictive value (99% vs 99%; p = NS) when compared to ex-ST/ECG. Receiver operator characteristics (ROC) analysis showed the incremental diagnostic value of the ex-HF/QRS (area: 0.64, 95% Confidence Intervals, CI 0.51-0.77) over conventional ex-ST/ECG (0.60, CI 0.52-0.66) and Chest Pain Score (0.53, CI 0.48-0.59); p = NS on pairwise C-statistic. In patients with long-standing hypertension and CP submitted to risk stratification with exercise tolerance test, the novel ex-HF/QRS

  15. Magnitude, direction and location of the resultant dipole moment of the pig heart.

    Science.gov (United States)

    Hodgkin, B C; Nelson, C V; Angelakos, E T

    1976-04-01

    Vectorcardiograms were obtained from 50 young domestic pigs using the Nelson lead system. Compensation for body size and shape is achieved and the resultant dipole moment magnitude reflects heart size. A strong relationship was found between heart size and maximum magnitude. Dipole moment magnitude increased as four pigs increased from five to ten weeks of age. The dipole moment during QRS is considered in light of known pig heart excitation pattern. Dipole locations during QRS, calculated by computer solution of the Gabor-Nelson equations, were in agreement with heart location and excitation data.

  16. A multi-step method with signal quality assessment and fine-tuning procedure to locate maternal and fetal QRS complexes from abdominal ECG recordings

    International Nuclear Information System (INIS)

    Liu, Chengyu; Li, Peng; Zhao, Lina; Di Maria, Costanzo; Zhang, Henggui; Chen, Zhiqing

    2014-01-01

    Non-invasive monitoring of fetal electrocardiogram (fECG) plays an important role in detecting and diagnosing fetal diseases. This study aimed to develop a multi-step method for locating both maternal and fetal QRS complexes from abdominal ECG (aECG) recordings. The proposed method included four major steps: abdominal ECG pre-processing, maternal QRS complex locating, maternal ECG cancellation and fetal QRS complex locating. Signal quality assessment (SQA) and fine-tuning for maternal ECG (FTM) were implemented in the first and third steps, respectively. The method was then evaluated using 75 non-invasive 4-channel aECG recordings provided by the PhysioNet/Computing in Cardiology Challenge 2013. The F 1 measure, which is a new index introduced by Behar et al (2013 Proc. Comput. Cardiol. 40 297–300), was used to assess the locating accuracy. The other two indices, mean squared error of heart rate (MSE H R) between the fetal HR signals estimated from the reference and our method (MSE H R in bpm 2 ) and root mean squared difference between the corresponding fetal RR intervals (MSE R R in ms) were also used to assess the locating accuracy. Overall, for the maternal QRS complex, the F 1 measure was 98.4% from the method without the implementation of SQA, and it was improved to 99.8% with SQA. For the fetal QRS complex, the F 1 measure, MSE H R and MSE R R were 84.9%, 185.6 bpm 2 and 19.4 ms for the method without both SQA and FTM procedures. They were improved to 93.9%, 47.5 bpm 2 and 7.6 ms with both SQA and FTM procedures. These improvements were observed from each individual subject. It can be concluded that implementing both SQA and FTM procedures could achieve better performance for locating both maternal and fetal QRS complexes. (paper)

  17. Sodium channel blockade with QRS widening after an escitalopram overdose.

    Science.gov (United States)

    Schreffler, Susan M; Marraffa, Jeanna M; Stork, Christine M; Mackey, Jennifer

    2013-09-01

    Escitalopram is rarely associated with prolongation of the QTc interval; however, there are no reported cases of QRS complex widening associated with escitalopram overdose. We report a case of a patient who presented with both QRS complex widening and QTc interval prolongation after an escitalopram overdose. A 16-year-old girl presented to the emergency department after ingestion of escitalopram, tramadol/acetaminophen, and hydrocodone/acetaminophen. Laboratory results were significant for 4-hour acetaminophen 21.1 μg/mL. Serum electrolytes including potassium, magnesium, and calcium were all normal. Initial electrocardiogram (ECG) revealed a widened QRS with an incomplete right bundle branch pattern. After administration of 100-mEq sodium bicarbonate, a repeat ECG revealed narrowing of the QRS complex and a prolonged QTc interval. Magnesium sulfate 2 g intravenous and sodium bicarbonate drip were initiated. A repeat ECG, 1 hour after the second, revealed normalization of the QRS complex and QTc interval. Prolongation of the QTc interval is an expected effect of escitalopram. Both escitalopram and citalopram are metabolized to the cardiotoxic metabolite S-didesmethylcitalopram and didesmethylcitalopram, respectively, which have been implicated in numerous cardiac abnormalities including widening of the QRS complex. Although never previously described with escitalopram, this mechanism provides a reasonable explanation for the QRS complex widening and incomplete right bundle branch block that occurred in our patient. Both QRS complex widening and QTc interval prolongation should be monitored in cases of escitalopram and citalopram overdoses.

  18. The Selvester QRS Score is more accurate than Q waves and fragmented QRS complexes using the Mason-Likar configuration in estimating infarct volume in patients with ischemic cardiomyopathy.

    Science.gov (United States)

    Carey, Mary G; Luisi, Andrew J; Baldwa, Sunil; Al-Zaiti, Salah; Veneziano, Marc J; deKemp, Robert A; Canty, John M; Fallavollita, James A

    2010-01-01

    Infarct volume independently predicts cardiovascular events. Fragmented QRS complexes (fQRS) may complement Q waves for identifying infarction; however, their utility in advanced coronary disease is unknown. We tested whether fQRS could improve the electrocardiographic prediction of infarct volume by positron emission tomography in 138 patients with ischemic cardiomyopathy (ejection fraction, 0.27 +/- 0.09). Indices of infarction (pathologic Q waves, fQRS, and Selvester QRS Score) were analyzed by blinded observers. In patients with QRS duration less than 120 milliseconds, number of leads with pathologic Q waves (mean, 1.6 +/- 1.7) correlated weakly with infarct volume (r = 0.30, P wave prediction of infarct volume; but Selvester Score was more accurate. Published by Elsevier Inc.

  19. Ivabradine, a novel heart rate slower: is it a sword of double blades in patients with idiopathic dilated cardiomyopathy?

    Science.gov (United States)

    Rayan, Mona; Tawfik, Mazen; Alabd, Ali; Gamal, Amr

    2011-08-01

    To prospectively assess the safety and efficacy of ivabradine in patients with idiopathic dilated cardiomyopathy. We included 35 patients with idiopathic dilated cardiomyopathy with an ejection fraction (EF) 70 beats/min despite optimal medical therapy, according to the international guidelines in this prospective, non-randomized, single-arm, open-label safety study. Ivabradine was used as an add-on therapy to the maximally tolerated b-blocker in an increasing titrated dose till a target dose of 15 mg/day or resting heart rate of 60 beats/min for 3 months. During follow-up period the safety, patient tolerance and efficacy of this drug were assessed. All patients underwent 12-lead resting electrocardiography and Holter monitoring at inclusion and after 3 months. Statistical analysis was accomplished using paired t-test and Pearson correlation analysis. We found a significant reduction in the resting heart rate by a mean of 25.9 ± 9.4%, without a significant change of blood pressure. There was no prolongation of PR, QTc or QRS durations. Ventricular ectopic activity showed significant reduction (p<0.001). There was a significant correlation between the resting heart rate, NYHA and left ventricular ejection fraction (p<0.001 for both). One patient developed photopsia and decompensation was observed in another patient. Ivabradine is a safe and effective drug in reducing resting heart rate, improving NYHA functional class without undesirable effects on conduction parameters or ectopic activity.

  20. Effects of Liraglutide on Heart Rate and Heart Rate Variability

    DEFF Research Database (Denmark)

    Kumarathurai, Preman; Anholm, Christian; Larsen, Bjørn Strøier

    2017-01-01

    OBJECTIVE: Reduced heart rate variability (HRV) and increased heart rate (HR) have been associated with cardiovascular mortality. Glucagon-like peptide 1 receptor agonists (GLP-1 RAs) increase HR, and studies have suggested that they may reduce HRV. We examined the effect of the GLP-1 RA...

  1. Mitral valve m-mode echo in complete heart block with atrial tachycardia

    Directory of Open Access Journals (Sweden)

    Kalathingathodika Sajeer

    2013-01-01

    Full Text Available We report a 48-year-old man who presented with history of syncope. Electrocardiogram on admission showed infrahisian complete heart block with a ventricular rate of 36 beats per min with wide QRS junctional escape and atrial rate was 188 beats per min. Transthoracic echocardiogram showed fine vibratory movement of both mitral leaflet tips. M-mode evaluation of mitral leaflets showed multiple ′a′ waves corresponding to atrial tachycardia rate.

  2. Heart rate monitoring mobile applications

    OpenAIRE

    Chaudhry, Beenish M.

    2016-01-01

    Total number of times a heart beats in a minute is known as the heart rate. Traditionally, heart rate was measured using clunky gadgets but these days it can be measured with a smartphone?s camera. This can help you measure your heart rate anywhere and at anytime, especially during workouts so you can adjust your workout intensity to achieve maximum health benefits. With simple and easy to use mobile app, ?Unique Heart Rate Monitor?, you can also maintain your heart rate history for personal ...

  3. Diastolic Pressure Difference to Classify Pulmonary Hypertension in the Assessment of Heart Transplant Candidates.

    Science.gov (United States)

    Wright, Stephen P; Moayedi, Yasbanoo; Foroutan, Farid; Agarwal, Suhail; Paradero, Geraldine; Alba, Ana C; Baumwol, Jay; Mak, Susanna

    2017-09-01

    The diastolic pressure difference (DPD) is recommended to differentiate between isolated postcapillary and combined pre-/postcapillary pulmonary hypertension (Cpc-PH) in left heart disease (PH-LHD). However, in usual practice, negative DPD values are commonly calculated, potentially related to the use of mean pulmonary artery wedge pressure (PAWP). We used the ECG to gate late-diastolic PAWP measurements. We examined the method's impact on calculated DPD, PH-LHD subclassification, hemodynamic profiles, and mortality. We studied patients with advanced heart failure undergoing right heart catheterization to assess cardiac transplantation candidacy (N=141). Pressure tracings were analyzed offline over 8 to 10 beat intervals. Diastolic pulmonary artery pressure and mean PAWP were measured to calculate the DPD as per usual practice (diastolic pulmonary artery pressure-mean PAWP). Within the same intervals, PAWP was measured gated to the ECG QRS complex to calculate the QRS-gated DPD (diastolic pulmonary artery pressure-QRS-gated PAWP). Outcomes occurring within 1 year were collected retrospectively from chart review. Overall, 72 of 141 cases demonstrated PH-LHD. Within PH-LHD, the QRS-gated DPD yielded higher calculated DPD values (3 [-1 to 6] versus 0 [-4 to 3] mm Hg; P pulmonary hypertension ( P pulmonary hypertension. The QRS-gated DPD reclassifies a subset of PH-LHD patients from isolated postcapillary pulmonary hypertension to Cpc-PH, which is characterized by an adverse hemodynamic profile. © 2017 American Heart Association, Inc.

  4. Heart rate monitoring mobile applications.

    Science.gov (United States)

    Chaudhry, Beenish M

    2016-01-01

    Total number of times a heart beats in a minute is known as the heart rate. Traditionally, heart rate was measured using clunky gadgets but these days it can be measured with a smartphone's camera. This can help you measure your heart rate anywhere and at anytime, especially during workouts so you can adjust your workout intensity to achieve maximum health benefits. With simple and easy to use mobile app, 'Unique Heart Rate Monitor', you can also maintain your heart rate history for personal reflection and sharing with a provider.

  5. Changes in electrical activity of heart during ischemic–reperfusion injury modified by the administration of antidepressants

    Directory of Open Access Journals (Sweden)

    Vicen M.

    2016-09-01

    Full Text Available The aim of our work was to investigate the effect of amitriptyline, citalopram and venlafaxine on the heart during ischemic- reperfusion (l-R injury. Amitriptyline prolonged both QRS complex and QTc interval duration; citalopram and venlafaxine prolonged only QTc interval duration. Amitriptyline worked most proarrhythmogenic, citalopram least; venlafaxine increased the heart rate during ischemia; however, prolonged QTc interval at the beginning of reperfusion was followed by serious dysrhythmias.

  6. Predicting QRS and PR interval prolongations in humans using nonclinical data.

    Science.gov (United States)

    Bergenholm, L; Parkinson, J; Mettetal, J; Evans, N D; Chappell, M J; Collins, T

    2017-10-01

    Risk of cardiac conduction slowing (QRS/PR prolongations) is assessed prior to clinical trials using in vitro and in vivo studies. Understanding the quantitative translation of these studies to the clinical situation enables improved risk assessment in the nonclinical phase. Four compounds that prolong QRS and/or PR (AZD1305, flecainide, quinidine and verapamil) were characterized using in vitro (sodium/calcium channels), in vivo (guinea pigs/dogs) and clinical data. Concentration-matched translational relationships were developed based on in vitro and in vivo modelling, and the in vitro to clinical translation of AZD1305 was quantified using an in vitro model. Meaningful (10%) human QRS/PR effects correlated with low levels of in vitro Na v 1.5 block (3-7%) and Ca v 1.2 binding (13-21%) for all compounds. The in vitro model developed using AZD1305 successfully predicted QRS/PR effects for the remaining drugs. Meaningful QRS/PR changes in humans correlated with small effects in guinea pigs and dogs (QRS 2.3-4.6% and PR 2.3-10%), suggesting that worst-case human effects can be predicted by assuming four times greater effects at the same concentration from dog/guinea pig data. Small changes in vitro and in vivo consistently translated to meaningful PR/QRS changes in humans across compounds. Assuming broad applicability of these approaches to assess cardiovascular safety risk for non-arrhythmic drugs, this study provides a means of predicting human QRS/PR effects of new drugs from effects observed in nonclinical studies. © 2017 The British Pharmacological Society.

  7. Heart rate response to breathing

    DEFF Research Database (Denmark)

    Mehlsen, J; Pagh, K; Nielsen, J S

    1987-01-01

    Heart rate responses to stepwise and periodic changes in lung volume were studied in seven young healthy males. Stepwise inspiration and expiration both resulted in an increase in heart rate followed by a rapid decrease in heart rate. The fastest heart rate was reached in 1.6 +/- 0.5 s and in 3.......6 +/- 1.4 s in response to inspiration and expiration, respectively (P less than 0.01). The slowest heart rate was reached in 4.8 +/- 1.0 s and in 7.6 +/- 1.9 s in response to inspiration and expiration, respectively (P less than 0.01). Following this biphasic change the heart rate returned to a steady...... level. The difference between the fastest and the slowest heart rates was significantly larger in response to inspiration (21.7 +/- 7.3 beats per minute) than in response to expiration (12.0 +/- 7.3 beats per minute; P less than 0.01). Periodic changes in lung volume were performed with frequencies from...

  8. Low QRS Voltage on Presenting Electrocardiogram Predicts Multi-vessel Disease in Anterior ST-segment Elevation Myocardial Infarction.

    Science.gov (United States)

    Kobayashi, Akihiro; Misumida, Naoki; Aoi, Shunsuke; Kanei, Yumiko

    Low QRS voltage was reported to predict adverse outcomes in acute myocardial infarction in the pre-thrombolytic era. However, the association between low voltage and angiographic findings has not been fully addressed. We performed a retrospective analysis of patients with anterior ST-segment elevation myocardial infarction (STEMI). Low QRS voltage was defined as either peak to peak QRS complex voltage voltage. Patients with low voltage had a higher rate of multi-vessel disease (MVD) (76% vs. 52%, p=0.01). Patients with low voltage were more likely to undergo coronary artery bypass grafting (CABG) during admission (11% vs. 2%, p=0.028). Low voltage was an independent predictor for MVD (OR 2.50; 95% CI 1.12 to 6.03; p=0.032). Low QRS voltage was associated with MVD and in-hospital CABG in anterior STEMI. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. An Analysis Of QRS Interval Of The Electrocardiogram In ...

    African Journals Online (AJOL)

    Objectives: This cross-sectional study of the 12-lead electrocardiogram (ECG) was undertaken to establish the normal QRS interval of the adult Nigerian from Jos; to find significant correlation coefficients for QRS interval and the various anthropometric measurements and also to establish prediction equations for the QRS ...

  10. A three-lead, programmable, and microcontroller-based electrocardiogram generator with frequency domain characteristics of heart rate variability.

    Science.gov (United States)

    Wei, Ying-Chieh; Wei, Ying-Yu; Chang, Kai-Hsiung; Young, Ming-Shing

    2012-04-01

    The objective of this study is to design and develop a programmable electrocardiogram (ECG) generator with frequency domain characteristics of heart rate variability (HRV) which can be used to test the efficiency of ECG algorithms and to calibrate and maintain ECG equipment. We simplified and modified the three coupled ordinary differential equations in McSharry's model to a single differential equation to obtain the ECG signal. This system not only allows the signal amplitude, heart rate, QRS-complex slopes, and P- and T-wave position parameters to be adjusted, but can also be used to adjust the very low frequency, low frequency, and high frequency components of HRV frequency domain characteristics. The system can be tuned to function with HRV or not. When the HRV function is on, the average heart rate can be set to a value ranging from 20 to 122 beats per minute (BPM) with an adjustable variation of 1 BPM. When the HRV function is off, the heart rate can be set to a value ranging from 20 to 139 BPM with an adjustable variation of 1 BPM. The amplitude of the ECG signal can be set from 0.0 to 330 mV at a resolution of 0.005 mV. These parameters can be adjusted either via input through a keyboard or through a graphical user interface (GUI) control panel that was developed using LABVIEW. The GUI control panel depicts a preview of the ECG signal such that the user can adjust the parameters to establish a desired ECG morphology. A complete set of parameters can be stored in the flash memory of the system via a USB 2.0 interface. Our system can generate three different types of synthetic ECG signals for testing the efficiency of an ECG algorithm or calibrating and maintaining ECG equipment. © 2012 American Institute of Physics

  11. Determinants of developing widened spatial QRS-T angle in HIV-infected individuals

    DEFF Research Database (Denmark)

    Dawood, Farah Z; Roediger, Mollie P; Grandits, Greg

    2014-01-01

    BACKGROUND: A widened electrocardiographic spatial QRS-T angle has been shown to be predictive of cardiovascular disease in HIV-infected individuals. However, determinants and risk factors of developing widened QRS-T angle over time in this population remain unknown. METHODS AND RESULTS: Spatial...... QRS-T angle was automatically measured from standard electrocardiogram of 1444 HIV-infected individuals without baseline widened spatial QRS-T angle from the Strategies for Management of Antiretroviral Therapy [SMART], a clinical trial comparing two antiretroviral treatment strategies [Drug...... Conservation (DC) vs. Viral Suppression (VS)]. Conditional logistic regression analysis was used to examine the association between baseline characteristics and incident widened spatial QRS-T angle (a new angle>93° in males and>74° in females). During 2544 person-years of follow-up, 199 participants developed...

  12. Dynamics and rate-dependence of the spatial angle between ventricular depolarization and repolarization wave fronts during exercise ECG.

    Science.gov (United States)

    Kenttä, Tuomas; Karsikas, Mari; Kiviniemi, Antti; Tulppo, Mikko; Seppänen, Tapio; Huikuri, Heikki V

    2010-07-01

    QRS/T angle and the cosine of the angle between QRS and T-wave vectors (TCRT), measured from standard 12-lead electrocardiogram (ECG), have been used in risk stratification of patients. This study assessed the possible rate dependence of these variables during exercise ECG in healthy subjects. Forty healthy volunteers, 20 men and 20 women, aged 34.6 +/- 3.4, underwent an exercise ECG testing. Twelve-lead ECG was recorded from each test subject and the spatial QRS/T angle and TCRT were automatically analyzed in a beat-to-beat manner with custom-made software. The individual TCRT/RR and QRST/RR patterns were fitted with seven different regression models, including a linear model and six nonlinear models. TCRT and QRS/T angle showed a significant rate dependence, with decreased values at higher heart rates (HR). In individual subjects, the second-degree polynomic model was the best regression model for TCRT/RR and QRST/RR slopes. It provided the best fit for both exercise and recovery. The overall TCRT/RR and QRST/RR slopes were similar between men and women during exercise and recovery. However, women had predominantly higher TCRT and QRS/T values. With respect to time, the dynamics of TCRT differed significantly between men and women; with a steeper exercise slope in women (women, -0.04/min vs -0.02/min in men, P exercise. The individual patterns of TCRT and QRS/T angle are affected by HR and gender. Delayed rate adaptation creates hysteresis in the TCRT/RR slopes.

  13. Presence of Fragmented QRS Complexes in Patients with Obstructive Sleep Apnea Syndrome

    Directory of Open Access Journals (Sweden)

    Muhammet Rasit Sayin

    2015-01-01

    Conclusions: In our study fragmented QRS frequency and QRS duration were found to increase in OSAS patients. Both parameters are related with increased cardiovascular mortality. Considering the prognostic importance of ECG parameters, it may be reasonable to recommend more detailed evaluation of OSAS patients with fragmented or prolonged QRS complexes with respect to presence of cardiovascular diseases.

  14. A deep learning approach for fetal QRS complex detection.

    Science.gov (United States)

    Zhong, Wei; Liao, Lijuan; Guo, Xuemei; Wang, Guoli

    2018-04-20

    Non-invasive foetal electrocardiography (NI-FECG) has the potential to provide more additional clinical information for detecting and diagnosing fetal diseases. We propose and demonstrate a deep learning approach for fetal QRS complex detection from raw NI-FECG signals by using a convolutional neural network (CNN) model. The main objective is to investigate whether reliable fetal QRS complex detection performance can still be obtained from features of single-channel NI-FECG signals, without canceling maternal ECG (MECG) signals. A deep learning method is proposed for recognizing fetal QRS complexes. Firstly, we collect data from set-a of the PhysioNet/computing in Cardiology Challenge database. The sample entropy method is used for signal quality assessment. Part of the bad quality signals is excluded in the further analysis. Secondly, in the proposed method, the features of raw NI-FECG signals are normalized before they are fed to a CNN classifier to perform fetal QRS complex detection. We use precision, recall, F-measure and accuracy as the evaluation metrics to assess the performance of fetal QRS complex detection. The proposed deep learning method can achieve relatively high precision (75.33%), recall (80.54%), and F-measure scores (77.85%) compared with three other well-known pattern classification methods, namely KNN, naive Bayes and SVM. the proposed deep learning method can attain reliable fetal QRS complex detection performance from the raw NI-FECG signals without canceling MECG signals. In addition, the influence of different activation functions and signal quality assessment on classification performance are evaluated, and results show that Relu outperforms the Sigmoid and Tanh on this particular task, and better classification performance is obtained with the signal quality assessment step in this study.

  15. Association between QRS duration on prehospital ECG and mortality in patients with suspected STEMI

    DEFF Research Database (Denmark)

    Hansen, Rikke; Frydland, Martin; Møller-Helgestad, Ole Kristian

    2017-01-01

    BACKGROUND: QRS duration has previously shown association with mortality in patients with acute myocardial infarction treated with thrombolytics, less is known in patients with suspected ST segment elevation myocardial infarction (STEMI) when assessing QRS duration on prehospital ECG. Thus......, the objective was to investigate the prognostic effect of QRS duration on prehospital ECG and presence of classic left and right bundle branch block (LBBB/RBBB) for all-cause mortality in patients with suspected STEMI. METHOD: In total 2105 consecutive patients (mean age 64±13years, 72% men) with suspected...... STEMI were prospectively included. QRS duration was registered from automated QRS measurement on prehospital ECG and patients were divided according to quartiles of QRS duration (111ms). Primary endpoint was all-cause 30-day mortality. Predictors of all-cause mortality were...

  16. QRS Width as a Predictor of Right Ventricular Remodeling After Percutaneous Pulmonary Valve Implantation.

    Science.gov (United States)

    Paech, C; Dähnert, I; Riede, F T; Wagner, R; Kister, T; Nieschke, K; Wagner, F; Gebauer, R A

    2017-08-01

    Recent data showed a right ventricular dyssynchrony in patients with tetralogy of Fallot (TOF). Percutaneous pulmonary valve implantation (PPVI) has become an important procedure to treat a pulmonary stenosis and/or regurgitation of the right ventricular outflow tract in these patients. Despite providing good results, there is still a considerable number of nonresponders to PPVI. The authors speculated that electrical dysfunction of the right ventricle plays an underestimated role in the outcome of patients after PPVI. This study aimed to investigate the influence of right ventricular electrical dysfunction, i.e., right bundle branch block (RBBB) on the RV remodeling after PPVI. The study included consecutive patients after correction of TOF with or without RBBB, who had received a PPVI previously at the Heart Center of the University of Leipzig, Germany during the period from 2012 to 2015. 24 patients were included. Patients without RBBB, i.e., with narrow QRS complexes pre-intervention, had significantly better RV function and had smaller right ventricular volumes. Patients with pre-interventionally QRS width below 150 ms showed a post-interventional remodeling of the right ventricle with the decreasing RV volumes (p = 0.001). The parameters of LV function and volume as well as RV ejection fraction remained unaffected by RBBB. The presented data indicate that the QRS width seems to be a valuable parameter in the prediction of right ventricular remodeling after PPVI, as it represents both electrical and mechanical functions of the right ventricle and may serve as an additional parameter for optimal timing of a PPVI.

  17. Heart rate variability in healthy population

    International Nuclear Information System (INIS)

    Alamgir, M.; Hussain, M.M.

    2010-01-01

    Background: Heart rate variability has been considered as an indicator of autonomic status. Little work has been done on heart rate variability in normal healthy volunteers. We aimed at evolving the reference values of heart rate variability in our healthy population. Methods: Twenty-four hour holter monitoring of 37 healthy individuals was done using Holter ECG recorder 'Life card CF' from 'Reynolds Medical'. Heart rate variability in both time and frequency domains was analysed with 'Reynolds Medical Pathfinder Digital/700'. Results: The heart rate variability in normal healthy volunteers of our population was found in time domain using standard deviation of R-R intervals (SDNN), standard deviation of average NN intervals (SDANN), and Square root of the mean squared differences of successive NN intervals (RMSSD). Variation in heart rate variability indices was observed between local and foreign volunteers and RMSSD was found significantly increased (p<0.05) in local population. Conclusions: The values of heart rate variability (RMSSD) in healthy Pakistani volunteers were found increased compared to the foreign data reflecting parasympathetic dominance in our population. (author)

  18. Cadmium stress assessment based on the electrocardiogram characteristics of zebra fish (Danio rerio): QRS complex could play an important role.

    Science.gov (United States)

    Xing, Na; Ji, Lizhen; Song, Jie; Ma, Jingchun; Li, Shangge; Ren, Zongming; Xu, Fei; Zhu, Jianping

    2017-10-01

    The electrocardiogram (ECG) of zebra fish (Danio rerio) expresses cardiac features that are similar to humans. Here we use sharp microelectrode measurements to obtain ECG characteristics in adult zebra fish and analyze the effects of cadmium chloride (CdCl 2 ) on the heart. We observe the overall changes of ECG parameters in different treatments (0.1 TU, 0.5 TU and 1.0 TU CdCl 2 ), including P wave, Q wave, R wave, S wave, T wave, PR interval (atrial contraction), QRS complex (ventricular depolarization), ST segment, and QT interval (ventricular repolarization). The trends of the ECG parameters showed some responses to the concentration and exposure time of CdCl 2 , but it was difficult to obtain more information about the useful indicators in water quality assessment depending on tendency analysis alone. A self-organizing map (SOM) showed that P values, R values, and T values were similar; R wave and T wave amplitude were similar; and most important, QRS value was similar to the CdCl 2 stress according to the classified data patterns including CdCl 2 stress (E) and ECG components based on the Ward linkage. It suggested that the duration of QRS complex was related to environmental stress E directly. The specification and evaluation of ECG parameters in Cd 2+ pollution suggested that there is a markedly significant correlation between QRS complex and CdCl 2 stress with the highest r (0.729) and the smallest p (0.002) among all ECG characteristics. In this case, it is concluded that QRS complex can be used as an indicator in the CdCl 2 stress assessment due to the lowest AIC data abased on the linear regression model between the CdCl 2 stress and ECG parameters. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Analysis of the temporal regression of the QRS widening induced by bupivacaine after Intralipid administration. Study in an experimental porcine model.

    Science.gov (United States)

    Zaballos, M; Sevilla, R; González, J; Callejo, D; de Diego, C; Almendral, J; Quintela, O; Anadón, M J

    2016-01-01

    The principal mechanism of cardiac toxicity of bupivacaine relates to the blockade of myocardial sodium channels, which leads to an increase in the QRS duration. Recently, experimental studies suggest that lipid emulsion is effective in reversing bupivacaine cardiac toxicity. We aimed to evaluate the temporal evolution of the QRS widening induced by bupivacaine with the administration of Intralipid. Twelve pigs were anesthetized with intravenous sodium thiopental 5mg kg(-1) and sevoflurane 1 MAC (2.6%). Femoral artery and vein were canalized for invasive monitoring, analysis of blood gases and determination of bupivacaine levels. After instrumentation and monitoring, a bupivacaine bolus of 4-6 mg kg(-1) was administered in order to induce a 150% increase in QRS duration (defined as the toxic point). The pigs were randomized into two groups of six individuals. Intralipid group (IL) received 1.5 mL kg(-1)of IL over one minute, followed by an infusion of 0.25 mL kg min(-1). Control group (C) received the same volume of a saline solution. The electrocardiographic parameters were recorded, and blood samples were taken after bupivacaine and 1, 5, 10 and 30 minutes after Intralipid/saline administration. Bupivacaine (4.33±0.81 mg/kg in IL group and 4.66±1.15 mg/kg in C group) induced similar electrocardiographic changes in both groups; mean maximal percent increase in QRS interval was 184±62% in IL group, and 230±56% in control group (NS). Lipid administration reversed the QRS widening previously impaired by bupivacaine. After ten minutes of the administration of IL, the mean QRS interval decreased to 132±56% vs. 15±76% relative to the maximum widening induced by bupivacaine, in IL and C group, respectively. Intralipid reversed the lengthening of QRS interval induced by the injection of bupivacaine. Time to normalization of electrocardiographic parameters can last more than 10 minutes. While the phenomena of cardiac toxicity persist, resuscitation measures and

  20. Monitoring apparatus for monitoring a user's heart rate and/or heart rate variation

    NARCIS (Netherlands)

    2012-01-01

    A monitoring apparatus (4) monitors a user's heart rate and/or heart rate variation. The apparatus includes a capacitor (22) which is positionable on or near a body part of a person, for example a person's limb, for example an arm (3), such that an electrical capacitance of the capacitor (22) is

  1. Reduced Dietary Sodium Intake Increases Heart Rate

    DEFF Research Database (Denmark)

    Graudal, Niels A; Hubeck-Graudal, Thorbjørn; Jürgens, Gesche

    2016-01-01

    Reduced dietary sodium intake (sodium reduction) increases heart rate in some studies of animals and humans. As heart rate is independently associated with the development of heart failure and increased risk of premature death a potential increase in heart rate could be a harmful side......-effect of sodium reduction. The purpose of the present meta-analysis was to investigate the effect of sodium reduction on heart rate. Relevant studies were retrieved from an updated pool of 176 randomized controlled trials (RCTs) published in the period 1973-2014. Sixty-three of the RCTs including 72 study...... populations reported data on heart rate. In a meta-analysis of these data sodium reduction increased heart rate with 1.65 beats per minute [95% CI: 1.19, 2.11], p heart rate. This effect was independent of baseline blood pressure. In conclusion sodium reduction...

  2. Detection of heart rate and rhythm with a smartphone-based electrocardiograph versus a reference standard electrocardiograph in dogs and cats.

    Science.gov (United States)

    Kraus, Marc S; Gelzer, Anna R; Rishniw, Mark

    2016-07-15

    OBJECTIVE To evaluate the diagnostic utility of ECGs acquired with a smartphone-based device, compared with reference 6-lead ECGs, for identification of heart rate and rhythm in dogs and cats. DESIGN Prospective study. ANIMALS 51 client-owned dogs and 27 client-owned cats. PROCEDURES Patients examined by a small animal referral cardiology service between April 2012 and January 2013 were enrolled consecutively. In each patient, a 30-second ECG was simultaneously acquired with a smartphone-based device (a bipolar, single-lead recorder coupled to a smartphone with an ECG application) and a standard 6-lead ECG machine. Recordings were evaluated by 3 board-certified cardiologists, and intra- and interobserver agreement were evaluated for both rhythm diagnosis and QRS polarity identification. RESULTS Values for instantaneous and mean heart rates for the smartphone-acquired and reference ECGs were within 1 beat of each other when mean heart rates were calculated. Intraobserver agreement for rhythm assessment was very high, with maximum disagreement for any observer for only 2 of 51 dogs and only 4 of 27 cats. There was minimal disagreement in the polarity of depolarization between the smartphone-acquired and reference ECGs in dogs but frequent disagreement in cats. Interobserver agreement for smartphone-acquired ECGs was similar to that for reference ECGs. with all 3 observers agreeing on the rhythm analysis and minimal disagreement on polarity. CONCLUSIONS AND CLINICAL RELEVANCE Results suggested that ECGs acquired with the smartphone-based device accurately identified heart rate and rhythm in dogs and cats. Thus, the device may allow veterinarians to evaluate and manage cardiac arrhythmias relatively inexpensively at the cage side and could also allow clinicians to rapidly share information via email for further consultation, potentially enhancing patient care.

  3. Fragmented QRS may predict new onset atrial fibrillation in patients with ST-segment elevation myocardial infarction.

    Science.gov (United States)

    Yesin, Mahmut; Kalçık, Macit; Çağdaş, Metin; Karabağ, Yavuz; Rencüzoğulları, İbrahim; Gürsoy, Mustafa Ozan; Efe, Süleyman Çağan; Karakoyun, Süleyman

    Fragmented QRS (fQRS) has been shown to be a marker of local myocardial conduction abnormalities, cardiac fibrosis in previous studies. It was also reported to be a predictor of sudden cardiac death and increased morbidity and mortality in selected populations. However, there is no study investigating the role of fQRS in the development of atrial fibrillation in patients with ST segment elevation myocardial infarction (STEMI). In this study we aimed to investigate the relationship between the presence of fQRS after primary percutaneous coronary intervention (pPCI) and in-hospital development of new-onset atrial fibrilation (AF) in patients with STEMI. This study enrolled 171 patients undergoing pPCI for STEMI. Among these patients 24 patients developed AF and the remaining 147 patients were designated as the controls. All clinical, demographical and laboratory parameters were entered into a dataset and compared between AF group and the controls. The presence of fQRS was higher in the AF group than in the controls (P=0.001). Diabetes mellitus and fQRS was significantly more common in the AF group (P=0.003 and P=0.001 respectively) Logistic regression analysis demonstrated that the presence of fQRS was the independent determinant of AF (OR: 3.243, 95% CI 1.016-10.251, P=0.042). Increased atrial fibrillation was observed more frequently in STEMI patients with fQRS than in patients without fQRS. fQRS is an important determinant of AF in STEMI after pPCI. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Aiding the Detection of QRS Complex in ECG Signals by Detecting S Peaks Independently.

    Science.gov (United States)

    Sabherwal, Pooja; Singh, Latika; Agrawal, Monika

    2018-03-30

    In this paper, a novel algorithm for the accurate detection of QRS complex by combining the independent detection of R and S peaks, using fusion algorithm is proposed. R peak detection has been extensively studied and is being used to detect the QRS complex. Whereas, S peaks, which is also part of QRS complex can be independently detected to aid the detection of QRS complex. In this paper, we suggest a method to first estimate S peak from raw ECG signal and then use them to aid the detection of QRS complex. The amplitude of S peak in ECG signal is relatively weak than corresponding R peak, which is traditionally used for the detection of QRS complex, therefore, an appropriate digital filter is designed to enhance the S peaks. These enhanced S peaks are then detected by adaptive thresholding. The algorithm is validated on all the signals of MIT-BIH arrhythmia database and noise stress database taken from physionet.org. The algorithm performs reasonably well even for the signals highly corrupted by noise. The algorithm performance is confirmed by sensitivity and positive predictivity of 99.99% and the detection accuracy of 99.98% for QRS complex detection. The number of false positives and false negatives resulted while analysis has been drastically reduced to 80 and 42 against the 98 and 84 the best results reported so far.

  5. Effects of social stress on heart rate and heart rate variability in growing pigs

    NARCIS (Netherlands)

    Jong, de I.C.; Sgoifo, A.; Lambooij, E.; Korte, S.M.; Blokhuis, H.J.; Koolhaas, J.M.

    2000-01-01

    The effects of social stress on heart rate, heart rate variability and the occurrence of cardiac arrhythmias were studied in 12 growing pigs. Social stress was induced during a good competition test with a pen mate, and subsequently during a resident-intruder test with an unacquainted pig in which

  6. Effects of social stress on heart rate and heart rate variability in growing pigs

    NARCIS (Netherlands)

    de Jong, IC; Sgoifo, A; Lambooij, E; Korte, SM; Blokhuis, HJ; Koolhaas, JM

    The effects of social stress on heart rate, heart rate variability and the occurrence of cardiac arrhythmias were studied in 12 growing pigs. Social stress was induced during a good competition test with a pen mate, and subsequently during a resident-intruder test with an unacquainted pig in which

  7. Effects of electric paravertebral muscle relaxation processes in the athletes heart

    Directory of Open Access Journals (Sweden)

    D. V. Syshko

    2013-02-01

    Full Text Available Influence of paravertebrals miorelaxation on electric processes in a heart at sportsmen is studied. Paravertebrals miorelaxation was the complex of exercises in a water environment directed on the decline of tone of paravertebral muscles. Before and after it was used of paravertebrals miorelaxation registered the indexes of electrocardiography at the sportsmen engaged in the Greek-Roman fight (n=22 by football (n=24 and heavy athletics (n=25. It is got, that at the sportsmen of engaged in the Greek -Roman fight after paravertebrals miorelaxation QRS and QT were it was increased, and R-R and PQ went down. At the sportsmen of engaged in heavy athletics HR and PQ went down after paravertebrals miorelaxation, R-R, QRS and QT were it was increased. At the sportsmen of getting busy by football the PQ interval shortened, and QRS and QT has multiplied. Findings testify to the presence of different mechanisms of adaptation of the conducting system of heart in the conditions of influencing of paravertebrals miorelaxation. These distinctions are fated by two basic factors: by the functional being of the cardio-vessels system on the whole and functional being of sine knot and conducting system of heart in particular.

  8. A real time QRS detection using delay-coordinate mapping for the microcontroller implementation.

    Science.gov (United States)

    Lee, Jeong-Whan; Kim, Kyeong-Seop; Lee, Bongsoo; Lee, Byungchae; Lee, Myoung-Ho

    2002-01-01

    In this article, we propose a new algorithm using the characteristics of reconstructed phase portraits by delay-coordinate mapping utilizing lag rotundity for a real-time detection of QRS complexes in ECG signals. In reconstructing phase portrait the mapping parameters, time delay, and mapping dimension play important roles in shaping of portraits drawn in a new dimensional space. Experimentally, the optimal mapping time delay for detection of QRS complexes turned out to be 20 ms. To explore the meaning of this time delay and the proper mapping dimension, we applied a fill factor, mutual information, and autocorrelation function algorithm that were generally used to analyze the chaotic characteristics of sampled signals. From these results, we could find the fact that the performance of our proposed algorithms relied mainly on the geometrical property such as an area of the reconstructed phase portrait. For the real application, we applied our algorithm for designing a small cardiac event recorder. This system was to record patients' ECG and R-R intervals for 1 h to investigate HRV characteristics of the patients who had vasovagal syncope symptom and for the evaluation, we implemented our algorithm in C language and applied to MIT/BIH arrhythmia database of 48 subjects. Our proposed algorithm achieved a 99.58% detection rate of QRS complexes.

  9. Diagnostic value of fragmented QRS complex in myocardial scar detection: systematic review and meta-analysis of the literature.

    Science.gov (United States)

    Sadeghi, Ramin; Dabbagh, Vahid-Reza; Tayyebi, Mohammad; Zakavi, Seyed Rasoul; Ayati, Narjess

    2016-01-01

    The present study aimed to investigate the diagnostic value of fragmented QRS complex (fQRS) on 12-lead electrocardiogram (ECG) for myocardial scar detection, and presented the results in a systematic review and meta-analysis format. Medline, SCOPUS, and ISI Web of Knowledge were searched electronically with "Fragmented QRS" or "fQRS" as key words. All related studies that had evaluated the accuracy of fQRS for myocardial scar diagnosis were included. Eight studies (2560 patients) were finally included in the systematic review. Specificity assessment could be evaluated only by five out of these eight articles. Overall pooled sensitivity of fQRS, Q wave, and mixed Q-fQRS was 68% (65-71), 51% (47-55), and 74% (69-79) and the pooled specificity was 80% (79-81), 97% (97-98) and 92% (91-93), respectively. Fragmented QRS is a novel ECG marker with more sensitivity and less specificity than Q wave. A combination of fQRS with Q wave in a 12-lead ECG results in up to 74% sensitivity and 92% specificity. Additional studies are needed to assess the significance of this ECG parameter for regional myocardial scar detection.

  10. Correlation between Amitriptyline-Induced Cardiotoxic Effects and Cardiac S100b Protein in Isolated Rat Hearts

    Directory of Open Access Journals (Sweden)

    Nil Hocaoğlu

    2016-12-01

    Full Text Available Background: Amitriptyline is an important cause of mortality due to its cardiovascular toxicity. Aims: To investigate the changes in levels of cardiac S100b protein on amitriptyline-induced cardiotoxicity and also to examine the correlation between amitriptyline-induced cardiotoxic effects and cardiac S100b protein in an isolated rat heart model. Study Design: Animal experimentation, isolated heart model. Methods: After a stabilization period, isolated hearts were randomized to two groups (n=5 and n=7. In the control group, isolated hearts were subjected to an infusion of 5% dextrose for 60 minutes. In the amitriptyline group, 5.5×10-5 M amitriptyline was infused for 60 minutes to achieve amitriptyline toxicity. After the infusion period, heart tissues were removed for histological examination. Results: In comparison to control treatment, amitriptyline infusion decreased left ventricular developed pressure (LVDP, dp/dtmax and heart rate (HR and significantly prolonged QRS duration (p<0.05. The semiquantitative scores for S100b protein levels in amitriptyline-infused hearts were higher than in the control group (p<0.01. At the end of the experiment, in the amitriptyline-infused group, significant correlations were found between LVDP and S100b protein scores (r=-0.807, p=0.003 and between QRS duration and S100b protein scores (r=0.859, p=0.001. Conclusion: Our results indicate that the S100b protein may be a helpful indicator or biomarker in studying the cardiotoxic effects of amitriptyline.

  11. Dimensional analysis of heart rate variability in heart transplant recipients

    Energy Technology Data Exchange (ETDEWEB)

    Zbilut, J.P.; Mayer-Kress, G.; Geist, K.

    1987-01-01

    We discuss periodicities in the heart rate in normal and transplanted hearts. We then consider the possibility of dimensional analysis of these periodicities in transplanted hearts and problems associated with the record.

  12. Rapid recovery from congestive heart failure following successful radiofrequency catheter ablation in a patient with late onset of Wolff-Parkinson-White syndrome.

    Science.gov (United States)

    Yodogawa, Kenji; Ono, Norihiko; Seino, Yoshihiko

    2012-01-01

    A 56-year-old man was admitted because of palpitations and dyspnea. A 12-lead electrocardiogram showed irregular wide QRS complex tachycardia with a slur at the initial portion of the QRS complex. He had preexisting long-standing persistent atrial fibrillation, but early excitation syndrome had never been noted. Chest X-ray showed heart enlargement and pulmonary congestion. He was diagnosed with late onset of Wolff-Parkinson-White syndrome, and congestive heart failure was probably caused by rapid ventricular response of atrial fibrillation through the accessory pathway. Emergency catheter ablation for the accessory pathway was undertaken, and heart failure was dramatically improved.

  13. A Combined Syntactical and Statistical Approach for R Peak Detection in Real-Time Long-Term Heart Rate Variability Analysis

    Directory of Open Access Journals (Sweden)

    David Pang

    2018-06-01

    Full Text Available Long-term heart rate variability (HRV analysis is useful as a noninvasive technique for autonomic nervous system activity assessment. It provides a method for assessing many physiological and pathological factors that modulate the normal heartbeat. The performance of HRV analysis systems heavily depends on a reliable and accurate detection of the R peak of the QRS complex. Ectopic beats caused by misdetection or arrhythmic events can introduce bias into HRV results, resulting in significant problems in their interpretation. This study presents a novel method for long-term detection of normal R peaks (which represent the normal heartbeat in electrocardiographic signals, intended specifically for HRV analysis. The very low computational complexity of the proposed method, which combines and exploits the advantages of syntactical and statistical approaches, enables real-time applications. The approach was validated using the Massachusetts Institute of Technology–Beth Israel Hospital Normal Sinus Rhythm and the Fantasia database, and has a sensitivity, positive predictivity, detection error rate, and accuracy of 99.998, 99.999, 0.003, and 99.996%, respectively.

  14. Identification of QRS complex in non-stationary electrocardiogram of sick infants.

    Science.gov (United States)

    Kota, S; Swisher, C B; Al-Shargabi, T; Andescavage, N; du Plessis, A; Govindan, R B

    2017-08-01

    Due to the high-frequency of routine interventions in an intensive care setting, electrocardiogram (ECG) recordings from sick infants are highly non-stationary, with recurrent changes in the baseline, alterations in the morphology of the waveform, and attenuations of the signal strength. Current methods lack reliability in identifying QRS complexes (a marker of individual cardiac cycles) in the non-stationary ECG. In the current study we address this problem by proposing a novel approach to QRS complex identification. Our approach employs lowpass filtering, half-wave rectification, and the use of instantaneous Hilbert phase to identify QRS complexes in the ECG. We demonstrate the application of this method using ECG recordings from eight preterm infants undergoing intensive care, as well as from 18 normal adult volunteers available via a public database. We compared our approach to the commonly used approaches including Pan and Tompkins (PT), gqrs, wavedet, and wqrs for identifying QRS complexes and then compared each with manually identified QRS complexes. For preterm infants, a comparison between the QRS complexes identified by our approach and those identified through manual annotations yielded sensitivity and positive predictive values of 99% and 99.91%, respectively. The comparison metrics for each method are as follows: PT (sensitivity: 84.49%, positive predictive value: 99.88%), gqrs (85.25%, 99.49%), wavedet (95.24%, 99.86%), and wqrs (96.99%, 96.55%). Thus, the sensitivity values of the four methods previously described, are lower than the sensitivity of the method we propose; however, the positive predictive values of these other approaches is comparable to those of our method, with the exception of the wqrs approach, which yielded a slightly lower value. For adult ECG, our approach yielded a sensitivity of 99.78%, whereas PT yielded 99.79%. The positive predictive value was 99.42% for both our approach as well as for PT. We propose a novel method for

  15. FPGA Implementation of Heart Rate Monitoring System.

    Science.gov (United States)

    Panigrahy, D; Rakshit, M; Sahu, P K

    2016-03-01

    This paper describes a field programmable gate array (FPGA) implementation of a system that calculates the heart rate from Electrocardiogram (ECG) signal. After heart rate calculation, tachycardia, bradycardia or normal heart rate can easily be detected. ECG is a diagnosis tool routinely used to access the electrical activities and muscular function of the heart. Heart rate is calculated by detecting the R peaks from the ECG signal. To provide a portable and the continuous heart rate monitoring system for patients using ECG, needs a dedicated hardware. FPGA provides easy testability, allows faster implementation and verification option for implementing a new design. We have proposed a five-stage based methodology by using basic VHDL blocks like addition, multiplication and data conversion (real to the fixed point and vice-versa). Our proposed heart rate calculation (R-peak detection) method has been validated, using 48 first channel ECG records of the MIT-BIH arrhythmia database. It shows an accuracy of 99.84%, the sensitivity of 99.94% and the positive predictive value of 99.89%. Our proposed method outperforms other well-known methods in case of pathological ECG signals and successfully implemented in FPGA.

  16. QRS analysis using wavelet transformation for the prediction of response to cardiac resynchronization therapy: a prospective pilot study.

    Science.gov (United States)

    Vassilikos, Vassilios P; Mantziari, Lilian; Dakos, Georgios; Kamperidis, Vasileios; Chouvarda, Ioanna; Chatzizisis, Yiannis S; Kalpidis, Panagiotis; Theofilogiannakos, Efstratios; Paraskevaidis, Stelios; Karvounis, Haralambos; Mochlas, Sotirios; Maglaveras, Nikolaos; Styliadis, Ioannis H

    2014-01-01

    Wider QRS and left bundle branch block morphology are related to response to cardiac resynchronization therapy (CRT). A novel time-frequency analysis of the QRS complex may provide additional information in predicting response to CRT. Signal-averaged electrocardiograms were prospectively recorded, before CRT, in orthogonal leads and QRS decomposition in three frequency bands was performed using the Morlet wavelet transformation. Thirty eight patients (age 65±10years, 31 males) were studied. CRT responders (n=28) had wider baseline QRS compared to non-responders and lower QRS energies in all frequency bands. The combination of QRS duration and mean energy in the high frequency band had the best predicting ability (AUC 0.833, 95%CI 0.705-0.962, p=0.002) followed by the maximum energy in the high frequency band (AUC 0.811, 95%CI 0.663-0.960, p=0.004). Wavelet transformation of the QRS complex is useful in predicting response to CRT. © 2013.

  17. The value of electrocardiography for differential diagnosis in wide QRS complex tachycardia.

    Science.gov (United States)

    Sousa, Pedro A; Pereira, Salomé; Candeias, Rui; de Jesus, Ilídio

    2014-03-01

    Correct diagnosis in wide QRS complex tachycardia remains a challenge. Differential diagnosis between ventricular and supraventricular tachycardia has important therapeutic and prognostic implications, and although data from clinical history and physical examination may suggest a particular origin, it is the 12-lead surface electrocardiogram that usually enables this differentiation. Since 1978, various electrocardiographic criteria have been proposed for the differential diagnosis of wide complex tachycardias, particularly the presence of atrioventricular dissociation, and the axis, duration and morphology of QRS complexes. Despite the wide variety of criteria, diagnosis is still often difficult, and errors can have serious consequences. To reduce such errors, several differential diagnosis algorithms have been proposed since 1991. However, in a small percentage of wide QRS tachycardias the diagnosis remains uncertain and in these the wisest decision is to treat them as ventricular tachycardias. The authors' objective was to review the main electrocardiographic criteria and differential diagnosis algorithms of wide QRS tachycardia. Copyright © 2012 Sociedade Portuguesa de Cardiologia. Published by Elsevier España. All rights reserved.

  18. On-Line QRS Complex Detection Using Wavelet Filtering

    National Research Council Canada - National Science Library

    Szilagyi, L

    2001-01-01

    ...: first a wavelet transform filtering is applied to the signal, then QRS complex localization is performed using a maximum detection and peak classification algorithm The algorithm has been tested...

  19. Reduced intrinsic heart rate is associated with reduced arrhythmic susceptibility in guinea-pig heart.

    Science.gov (United States)

    Osadchii, Oleg E

    2014-12-01

    In the clinical setting, patients with slower resting heart rate are less prone to cardiovascular death compared with those with elevated heart rate. However, electrophysiological adaptations associated with reduced cardiac rhythm have not been thoroughly explored. In this study, relationships between intrinsic heart rate and arrhythmic susceptibility were examined by assessments of action potential duration (APD) rate adaptation and inducibility of repolarization alternans in sinoatrial node (SAN)-driven and atrioventricular (AV)-blocked guinea-pig hearts perfused with Langendorff apparatus. Electrocardiograms, epicardial monophasic action potentials, and effective refractory periods (ERP) were assessed in normokalemic and hypokalemic conditions. Slower basal heart rate in AV-blocked hearts was associated with prolonged ventricular repolarization during spontaneous beating, and with attenuated APD shortening at increased cardiac activation rates during dynamic pacing, when compared with SAN-driven hearts. During hypokalemic perfusion, the inducibility of repolarization alternans and tachyarrhythmia by rapid pacing was found to be lower in AV-blocked hearts. This difference was ascribed to prolonged ERP in the setting of reduced basal heart rate, which prevented ventricular capture at critically short pacing intervals required to induce arrhythmia. Reduced basal heart rate is associated with electrophysiological changes that prevent electrical instability upon an abrupt cardiac acceleration.

  20. The Variability of Automated QRS Duration Measurement

    Czech Academy of Sciences Publication Activity Database

    Vančura, V.; Wichterle, D.; Ulč, I.; Šmíd, J.; Brabec, Marek; Zárybnická, M.; Rokyta, R.

    2017-01-01

    Roč. 19, č. 4 (2017), s. 636-643 ISSN 1099-5129 Institutional support: RVO:67985807 Keywords : ECG * QRS complex * automated measurement Subject RIV: FA - Cardiovascular Diseases incl. Cardiotharic Surgery OBOR OECD: Statistics and probability Impact factor: 4.530, year: 2016

  1. Heart-Rate Recovery After Warm-up in Swimming: A Useful Predictor of Training Heart-Rate Response?

    Science.gov (United States)

    Ganzevles, Sander P M; de Haan, Arnold; Beek, Peter J; Daanen, Hein A M; Truijens, Martin J

    2017-07-01

    For training to be optimal, daily training load has to be adapted to the momentary status of the individual athlete, which is often difficult to establish. Therefore, the current study investigated the predictive value of heart-rate recovery (HRR) during a standardized warm-up for training load. Training load was quantified by the variation in heart rate during standardized training in competitive swimmers. Eight female and 5 male Dutch national-level swimmers participated in the study. They all performed 3 sessions consisting of a 300-m warm-up test and a 10 × 100-m training protocol. Both protocols were swum in front crawl at individually standardized velocities derived from an incremental step test. Velocity was related to 75% and 85% heart-rate reserve (% HR res ) for the warm-up and training, respectively. Relative HRR during the first 60 s after the warm-up (HR Rw-up ) and differences between the actual and intended heart rate for the warm-up and the training (ΔHR w-up and ΔHR tr ) were determined. No significant relationship between HRR w-up and ΔHR tr was found (F 1,37 = 2.96, P = .09, R 2 = .07, SEE = 4.65). There was considerable daily variation in ΔHR tr at a given swimming velocity (73-93% HR res ). ΔHR w-up and ΔHR tr were clearly related (F 1,37 = 74.31, P warm-up does not predict heart rate during a directly subsequent and standardized training session. Instead, heart rate during the warm-up protocol seems a promising alternative for coaches to make daily individual-specific adjustments to training programs.

  2. Predictors of ventricular tachyarrhythmia occurring late after intracardiac repair of tetralogy of Fallot: combination of QRS duration change rate and tricuspid regurgitation pressure gradient

    Science.gov (United States)

    Takahashi, Masashi; Sugimoto, Ai; Tsuchida, Masanori

    2017-01-01

    Background To determine potential predictors of ventricular tachyarrhythmia and sudden cardiac death (SCD) occurring late after repair of tetralogy of Fallot (TOF). Methods Since 1964, 415 patients had undergone total repair for TOF at Niigata University Hospital. Of these, 89 patients who were followed for more than 10 years at our institute were retrospectively reviewed. Results The mean follow-up period was 24.3 years. During the study period, one patient died of cerebral bleeding, and two patients had SCD. The overall survival rates at 20, 30, and 40 years were 100%, 94.6%, and 94.6%, respectively. Eight (9.0%) patients required re-intervention during the late period associated with right ventricular outflow (n=4), tricuspid valve (n=3), aortic valve (n=2), and others (n=2). Ten (11.2%) patients had a history of ventricular tachycardia (VT) or ventricular fibrillation (VF), and six underwent implantation of an implantable cardiac defibrillator. Multivariate analysis selected the change rate of QRS duration [ms/year; odds ratio (OR), 2.44; 95% confidence interval (CI): 1.28–4.65; P=0.007] and the pressure gradient at tricuspid valve regurgitation on echocardiography (OR, 1.12; 95% CI: 1.02–1.22; P=0.017) as risk factors for VT/VF or SCD. Trans-annular patch (TAP) repair was not an independent risk factor for ventricular arrhythmia. Conclusions The combination of rapid change rate of QRS duration and higher-pressure gradient at tricuspid regurgitation were risk factors for ventricular tachyarrhythmia late after TOF repair. Adequate surgical or catheter intervention for pressure and volume load in the right ventricle might decrease the prevalence of VT/VF and SCD. PMID:29312717

  3. Heart rate profile during exercise in patients with early repolarization.

    Science.gov (United States)

    Cay, Serkan; Cagirci, Goksel; Atak, Ramazan; Balbay, Yucel; Demir, Ahmet Duran; Aydogdu, Sinan

    2010-09-01

    Both early repolarization and altered heart rate profile are associated with sudden death. In this study, we aimed to demonstrate an association between early repolarization and heart rate profile during exercise. A total of 84 subjects were included in the study. Comparable 44 subjects with early repolarization and 40 subjects with normal electrocardiogram underwent exercise stress testing. Resting heart rate, maximum heart rate, heart rate increment and decrement were analyzed. Both groups were comparable for baseline characteristics including resting heart rate. Maximum heart rate, heart rate increment and heart rate decrement of the subjects in early repolarization group had significantly decreased maximum heart rate, heart rate increment and heart rate decrement compared to control group (all P decrement (multiple-adjusted OR of the risk of presence of early repolarization was 2.98 (95%CI 1.21-7.34) (P = 0.018) and 7.73 (95%CI 2.84-21.03) (P decrement compared to higher levels, respectively. Subjects with early repolarization have altered heart rate profile during exercise compared to control subjects. This can be related to sudden death.

  4. Correlation of Fragmented QRS with Right Ventricular Indexes and Fibrosis in Patients with Repaired Tetralogy of Fallot, by Cardiac Magnetic Resonance Imaging

    Directory of Open Access Journals (Sweden)

    Zahra Alizadeh Sani

    2017-09-01

    Full Text Available Background: Repair of tetralogy of fallot (TOF is associated with diffuse myocardial fibrosis. Cardiac magnetic resonance imaging (CMR can visualize the areas with myocardial fibrosis. Presence of fragmented QRS (fQRS implies the presence of the underlying myocardial scar. Despite the strong association between fQRS and myocardial pathologies, the impact of fQRS with myocardial fibrosis in post-TOF correction is unknown. Objectives: Here, we evaluated the possible predictive role of fQRS in repaired TOF cases and its relationship with cardiac function. Patients and Methods: Thirty two patients with previous history of repaired TOF were enrolled. The extent of fQRS was evaluated according to the number of leads with fQRS. After electrocardiographic evaluation, the participants underwent CMR. Results: Results showed a significant relationship between the right ventricular (RV systolic diameter and fQRS (P = 0.014. Also, an inverse linear relationship was found between the number of fQRS edges and RVEF (r = 0.77, P = 0.0001. The mean QRS duration in those with positive and negative fQRS was 132 mm and 115.8 mm (P = 0.0001. Furthermore, a linear correlation was observed between the number of edges and the percentage of scar tissue (r = 0.88, P = 0.001. However, no relevance between gender and fQRS was detected (P = 0.26, and the relationship between RV diastolic diameter and fQRS was not significant (P = 0.1. Thus, fQRS could be used as a marker of RV systolic dysfunction in patients with tetralogy of fallot. Conclusions: We suggested the fQRS as a surrogate indicator of RV dysfunction in repaired TOF patients and showed that diagnostic and prognostic information of the patients were available by fQRS.

  5. Genome-wide association studies and resting heart rate

    DEFF Research Database (Denmark)

    Oskari Kilpeläinen, Tuomas

    2016-01-01

    Genome-wide association studies (GWASs) have revolutionized the search for genetic variants regulating resting heart rate. In the last 10 years, GWASs have led to the identification of at least 21 novel heart rate loci. These discoveries have provided valuable insights into the mechanisms...... and pathways that regulate heart rate and link heart rate to cardiovascular morbidity and mortality. GWASs capture majority of genetic variation in a population sample by utilizing high-throughput genotyping chips measuring genotypes for up to several millions of SNPs across the genome in thousands...... of individuals. This allows the identification of the strongest heart rate associated signals at genome-wide level. While GWASs provide robust statistical evidence of the association of a given genetic locus with heart rate, they are only the starting point for detailed follow-up studies to locate the causal...

  6. Response of the ECG to short-term diuresis in patients with heart failure.

    Science.gov (United States)

    Madias, John E; Song, Jessica; White, C Michael; Kalus, James S; Kluger, Jeffrey

    2005-07-01

    Increase in the amplitude of electrocardiogram (ECG) QRS complexes has been observed in patients treated for heart failure (HF), but the underlying mechanism has not been delineated. Also, correlation of augmentation of the QRS potentials with loss of weight has been noted in patients recovering from anasarca of varying etiology, or after hemodialysis. We assessed the effect of diuresis-based fluid loss in patients treated for HF on the amplitude of ECG QRS complexes. This is a cohort study based on ECG and other data from a previously published investigation of patients with HF conducted at a university affiliated hospital, which used new measurements and analysis, performed by a totally blinded investigator based at another institution. Twenty-one patients (10 men) aged 70.5+/-12.7 years, 13 with ischemic, and 8 with nonischemic cardiomyopathy, were admitted to the hospital for management of exacerbated HF and were observed for 48 hours. The patients received diuresis, and had routine laboratory testing, documentation of the net fluid lost, and recording of ECGs prior to the initiation of therapy and at 24 and 48 hours. Percent change (%Delta) over the course of observation in the sums of the amplitude of QRS complexes from 12 leads (SigmaQRS12), 6-limb leads (SigmaQRS6), and leads 1+2 (SigmaQRS2) in mm of standard ECGs were correlated with net fluid loss corrected for admission weight in mL/kg. Fluid loss amounted to 3204.9+/-1399.5 mL in the course of 40+/-23 hours of diuresis. SigmaQRS12 was 160.9+/-42.3 mm before and 170.0+/-50.7 mm after diuresis (P=0. 024). Percent change in SigmaQRS12, SigmaQRS6, and SigmaQRS2 correlated well with the net fluid loss (r=-0.70, -0.82, -0.61, and P=0.002, 0.0005, 0.001) correspondingly. Changes in sums of the amplitude of QRS complexes of the standard ECG correlates well with net fluid loss in response to short-term diuresis in patients with HF. Change in the SigmaQRS12, SigmaQRS6, and SigmaQRS2 from ECGs before and after

  7. Heart Rate Variability - A Historical Perspective

    Directory of Open Access Journals (Sweden)

    George E Billman

    2011-11-01

    Full Text Available Heart rate variability (HRV, the beat-to-beat variation in either heart rate or the duration of the R-R interval – the heart period, has become a popular clinical and investigational tool. The temporal fluctuations in heart rate exhibit a marked synchrony with respiration (increasing during inspiration and decreasing during expiration – the so called respiratory sinus arrhythmia, RSA and are widely believed to reflect changes in cardiac autonomic regulation. Although the exact contributions of the parasympathetic and the sympathetic divisions of the autonomic nervous system to this variability are controversial and remain the subject of active investigation and debate, a number of time and frequency domain techniques have been developed to provide insight into cardiac autonomic regulation in both health and disease. It is the purpose of this essay to provide an historical overview of the evolution in the concept of heart rate variability. Briefly, pulse rate was first measured by ancient Greek physicians and scientists. However, it was not until the invention of the Physician’s Pulse Watch (a watch with a second hand that could be stopped in 1707 that changes in pulse rate could be accurately assessed. The Rev. Stephen Hales (1733 was the first to note that pulse varied with respiration and in 1847 Carl Ludwig was the first to record RSA. With the measurement of the ECG (1895 and advent of digital signal processing techniques in the 1960’s, investigation of HRV and its relationship to health and disease has exploded. This essay will conclude with a brief description of time domain, frequency domain, and non-linear dynamic analysis techniques (and their limitations that are commonly used to measure heart rate variability.

  8. QRS slopes for assessment of myocardial damage in chronic chagasic patients

    International Nuclear Information System (INIS)

    Pueyo, E; Laciar, E; Anzuola, E; Laguna, P; Jane, R

    2007-01-01

    In this study the slopes of the QRS complex are evaluated for determination of the degree of myocardial damage in chronic chagasic patients. Previous studies have demonstrated the ability of the slope indices to reflect alterations in the conduction velocity of the cardiac impulse. Results obtained in the present study show that chronic chagasic patients have significantly flatter QRS slopes as compared to healthy subjects. Not only that but the extent of slope lessening turns out to be proportional to the degree of myocardial damage caused by the disease. Additionally, when incorporating the slope indices into a classification analysis together with other indices indicative of the presence of ventricular late potentials obtained from high resolution electrocardiography, results show that the percentages of correct classification increase up to 62.5%, which means eight points above the percentages obtained prior to incorporation of the slope indices. It can be concluded that QRS slopes have great potential for assessing the degree of severity associated with Chagas' disease

  9. Peak heart rates at extreme altitudes

    DEFF Research Database (Denmark)

    Lundby, C; Van Hall, Gerrit

    2001-01-01

    We have measured maximal heart rate during a graded maximal bicycle exercise test to exhaustion in five healthy climbers before and during an expedition to Mt. Everest. Maximal heart rates at sea level were 186 (177-204) beats/min(-1) at sea level and 170 (169-182) beats/min(-1) with acute hypoxi...

  10. Electrocardiographic Changes in Certain Cardiovascular Physiological and Pathological Settings. Impact on Coronary Artery Bypass Grafting

    Directory of Open Access Journals (Sweden)

    Dimitar Simov

    2016-03-01

    Full Text Available Review on electrocardiographic changes provoked by aging, diagnostic tests, cardiac surgery, hemodialysis, diabetes, etc., is the objective of the current material. Several electrocardiographic (ECG parameters that are well known risk markers of arrhythmias, incidental heart failure and sudden cardiac death (SCD are discussed: QRS amplitude, QRS morphology, QRS duration, QRS alternans, T-wave amplitude, T-wave morphology, T-wave alternans, negative T-waves, 3D-spatial angle between maximal QRS and T vectors of the vectorcardiographic loops, ST-segment elevation, QT-interval dispersion, and heart rate. All reviewed parameters are compared with the results on the ECG-alterations, induced by coronary artery bypass grafting (CABG surgery. Two parameters showed an improvement in the patients' condition: QRS-T angle and cardiac autonomic innervation while two others (T-wave alternans and heart rate indicated deterioration. We tend to assume that the deterioration in this early post-operative period is an effect of the post-surgery trauma. We speculate that this effect will fade away in a period of a month and more after surgery, and we intend to conduct such a research in the future. The analysis of ECG's changes will help to better assess the impact of the CABG surgery.

  11. The effect of relaxing music on heart rate and heart rate variability during ECG GATED-myocardial perfusion scintigraphy.

    Science.gov (United States)

    Tan, Yusuf Ziya; Ozdemir, Semra; Temiz, Ahmet; Celik, Fatmanur

    2015-05-01

    The positive changes in human behavior caused by relaxing music demonstrate the psychological effect of music on human body. A meta-analytical study has shown that relaxing music affects blood pressure and heart rate in coronary heart patients and cancer patients. The aim of our study is to research whether there is a significant effect on heart rate and heart rate variability due to listening to relaxing music during ECG GATED MPS imaging under gamma camera. The music group (n = 50 patients) could choose from 15 different musical types including folk music (no lyric). The other 50 patients were placed in a "no music group" and did not get headphones or any music. There was a statistically significant reduction in the heart rate of patients in the music group compared to those in the control group. Relaxing music provides great benefits to both patient and clinician. There is close relationship between relaxing music and health procedure, can use every area of the health noninvasiv, safe, cheap and is a method don't have side effect. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Measuring heart rate with optical sensor

    NARCIS (Netherlands)

    Barachi, M. (Mitra)

    2014-01-01

    The problem addressed in this report is to verify the possibility of using an optical sensor in the SaxShirt in order to extract the heart rate. There are specifically three questions that we try to address. 1) How is it possible to extract heart rate (BPM) from the optical sensor? 2) Is it

  13. Validation of Heart Rate Monitor Polar RS800 for Heart Rate Variability Analysis During Exercise.

    Science.gov (United States)

    Hernando, David; Garatachea, Nuria; Almeida, Rute; Casajús, Jose A; Bailón, Raquel

    2018-03-01

    Hernando, D, Garatachea, N, Almeida, R, Casajús, JA, and Bailón, R. Validation of heart rate monitor Polar RS800 for heart rate variability analysis during exercise. J Strength Cond Res 32(3): 716-725, 2018-Heart rate variability (HRV) analysis during exercise is an interesting noninvasive tool to measure the cardiovascular response to the stress of exercise. Wearable heart rate monitors are a comfortable option to measure interbeat (RR) intervals while doing physical activities. It is necessary to evaluate the agreement between HRV parameters derived from the RR series recorded by wearable devices and those derived from an electrocardiogram (ECG) during dynamic exercise of low to high intensity. Twenty-three male volunteers performed an exercise stress test on a cycle ergometer. Subjects wore a Polar RS800 device, whereas ECG was also recorded simultaneously to extract the reference RR intervals. A time-frequency spectral analysis was performed to extract the instantaneous mean heart rate (HRM), and the power of low-frequency (PLF) and high-frequency (PHF) components, the latter centered on the respiratory frequency. Analysis was done in intervals of different exercise intensity based on oxygen consumption. Linear correlation, reliability, and agreement were computed in each interval. The agreement between the RR series obtained from the Polar device and from the ECG is high throughout the whole test although the shorter the RR is, the more differences there are. Both methods are interchangeable when analyzing HRV at rest. At high exercise intensity, HRM and PLF still presented a high correlation (ρ > 0.8) and excellent reliability and agreement indices (above 0.9). However, the PHF measurements from the Polar showed reliability and agreement coefficients around 0.5 or lower when the level of the exercise increases (for levels of O2 above 60%).

  14. Comparison between fragmented QRS and Q waves in myocardial scar detection using myocardial perfusion single photon emission computed tomography.

    Science.gov (United States)

    Dabbagh Kakhki, Vahid Reza; Ayati, Narjess; Zakavi, Seyed Rasoul; Sadeghi, Ramin; Tayyebi, Mohammad; Shariati, Farzaneh

    2015-01-01

    Accurate diagnosis of myocardial infarction (MI) is of paramount importance in patient management, which necessitates the development of efficient and accurate diagnostic methods. Q wave is not present in all patients with MI, and its prevalence is declining. Recently, fragmented QRS (fQRS) complex has been introduced as a marker of prior MI. To investigate diagnostic value of fQRS compared to Q wave. We included 500 consecutive patients with known or suspected coronary artery disease who underwent two days of gated myocardial perfusion imaging using dipyridamole pharmacologic stress. Electrocardiogram (ECG) was evaluated to detect fQRS as well as Q-wave. Finally, subjects were compared in terms of ventricular perfusion and function indices. A total of 207 men and 269 women with mean age of 57.06 ± 12 years were studied. ECG analysis showed that 14.3% of the patients had both fQRS and Q waves, 30.7% had fQRS, and 3.8% had Q waves. Fixed myocardial perfusion defect was noted in 22.3% of patients according to MPIs. Sensitivity, specificity, and positive and negative predictive values for myocardial scar detection were 78%, 65%, 39%, and 91%, respectively, for fQRS and 61%, 94%, 76%, and 89%, respectively, for Q wave. Although fQRS had lower specificity compared to Q wave in the detection of myocardial scar, due to higher sensitivity and negative predictive value can be an invaluable diagnostic index. There is also an incremental value for fQRS in association with Q-wave in myocardial scar assessment.

  15. Study Heart Rate by Tools from Complex Networks

    International Nuclear Information System (INIS)

    Makowiec, D.; Wdowczyk-Szulc, J.; Zarczynska-Buchowiecka, M.; Gruchala, M.; Rynkiewicz, A.

    2011-01-01

    Heart rate measured as beat-to-beat time intervals varies in time. It is believed that time intervals between subsequent normal heart contractions carry information about the regulatory system of the heart. How to quantify such signals is not clear and because of that heart rate variability is still apart from the clinic routine. In the following, we propose a method for representing a heart rate signal as a directed network. Then we study the signal properties by complex network tools. The signals to study were collected from patients recovering after the heart transplantation. The aim is to classify the progress of adapting of the new heart - graft. Moreover, it is expected that the method allows for visual classification. Our investigations are preliminary, however the obtained results are promising. (authors)

  16. Metaiodobenzylguanidine and heart rate variability in heart failure

    International Nuclear Information System (INIS)

    Kurata, Chinori; Shouda, Sakae; Mikami, Tadashi; Uehara, Akihiko; Ishikawa, Keiko; Tawarahara, Kei; Nakano, Tomoyasu; Matoh, Fumitaka; Takeuchi, Kazuhiko

    1998-01-01

    It is assumed that the low-frequency power (LF) of heart rate variability (HRV) increases with progress of congestive heart failure (CHF), therefore positively correlating with cardiac 123 I-metaiodobenzylguanidine (MIBG) washout. It is demonstrated here that HRV, including normalized LF, correlated inversely with MIBG washout and positively with the ratio of heart-to-mediastinum MIBG activity in controls and CHF patients, whereas these correlations were not observed within CHF patients. Thus MIBG washout may increase and HRV including normalized LF may decrease with CHF, although the HRV and MIBG measures may not similarly change in proportion to the severity of the cardiac autonomic dysfunction in CHF. (author)

  17. Metaiodobenzylguanidine and heart rate variability in heart failure

    Energy Technology Data Exchange (ETDEWEB)

    Kurata, Chinori; Shouda, Sakae; Mikami, Tadashi; Uehara, Akihiko; Ishikawa, Keiko [Hamamatsu Univ., Shizuoka (Japan). School of Medicine; Tawarahara, Kei; Nakano, Tomoyasu; Matoh, Fumitaka; Takeuchi, Kazuhiko

    1998-10-01

    It is assumed that the low-frequency power (LF) of heart rate variability (HRV) increases with progress of congestive heart failure (CHF), therefore positively correlating with cardiac {sup 123}I-metaiodobenzylguanidine (MIBG) washout. It is demonstrated here that HRV, including normalized LF, correlated inversely with MIBG washout and positively with the ratio of heart-to-mediastinum MIBG activity in controls and CHF patients, whereas these correlations were not observed within CHF patients. Thus MIBG washout may increase and HRV including normalized LF may decrease with CHF, although the HRV and MIBG measures may not similarly change in proportion to the severity of the cardiac autonomic dysfunction in CHF. (author)

  18. Predictive value of casual ECG-based resting heart rate compared with resting heart rate obtained from Holter recording

    DEFF Research Database (Denmark)

    Carlson, Nicholas; Dixen, Ulrik; Marott, Jacob L

    2014-01-01

    BACKGROUND: Elevated resting heart rate (RHR) is associated with cardiovascular mortality and morbidity. Assessment of heart rate (HR) from Holter recording may afford a more precise estimate of the effect of RHR on cardiovascular risk, as compared to casual RHR. Comparative analysis was carried ...

  19. Revisiting QRS Detection Methodologies for Portable, Wearable, Battery-Operated, and Wireless ECG Systems

    Science.gov (United States)

    Elgendi, Mohamed; Eskofier, Björn; Dokos, Socrates; Abbott, Derek

    2014-01-01

    Cardiovascular diseases are the number one cause of death worldwide. Currently, portable battery-operated systems such as mobile phones with wireless ECG sensors have the potential to be used in continuous cardiac function assessment that can be easily integrated into daily life. These portable point-of-care diagnostic systems can therefore help unveil and treat cardiovascular diseases. The basis for ECG analysis is a robust detection of the prominent QRS complex, as well as other ECG signal characteristics. However, it is not clear from the literature which ECG analysis algorithms are suited for an implementation on a mobile device. We investigate current QRS detection algorithms based on three assessment criteria: 1) robustness to noise, 2) parameter choice, and 3) numerical efficiency, in order to target a universal fast-robust detector. Furthermore, existing QRS detection algorithms may provide an acceptable solution only on small segments of ECG signals, within a certain amplitude range, or amid particular types of arrhythmia and/or noise. These issues are discussed in the context of a comparison with the most conventional algorithms, followed by future recommendations for developing reliable QRS detection schemes suitable for implementation on battery-operated mobile devices. PMID:24409290

  20. The relationship between phase and heart rate

    International Nuclear Information System (INIS)

    Underwood, S.R.; Walton, S.; Brown, N.J.G.; Laming, P.J.; Ell, P.J.; Emanuel, R.W.; Swanton, R.H.

    1984-01-01

    The Fourier phase image is used in rest and stress radionuclide angiocardiography to assess the timing of ventricular wall motion in a regional fashion, and areas of high phase are taken to reprensent areas of delayed contraction. However, phase increases with heart rate and this can make interpretation difficult. This study investigates the relationship between phase and heart rate. A heterogenous group of 43 subjects was studied by ECG-gated equilibrium radionuclide angiocardiography, all of the subjects having normal extent of left ventricular wall motion as judged by normal ejection fraction and normal amplitude image. Mean left ventricular phase correlated well with mean time of end systole (r=0.92), but there was no correlation with time of end diastole.Thus phase reflects the time of end systole as a proportion of cycle length and should be linearly related to heart rate provided the duration of systole is unchanged. In 28 normal subjects mean left ventricular phase correlated linearly with resting rate (r=0.91), and when exercised the relationship was maintained up to 90 beats per minute. Above this rate the increases were less marked as the duration of systole shortened. The same was true in 4 subjects paced at different rates. Mean resting heart rate in the normal subjects was 70 beats per minute and correcting phase linearly to rate 70 did not change mean left ventricular phase but did decrease the standard deviation from 18 degree to 12 degree. It is concluded that correcting phase for heart rate below 90 beats per minute will increase the sensitivity of the phase image to abnormalities of the timing of ventricular contraction. This correction should be appropriate in resting, isometric exercise, and cold pressor studies but because of the higher heart rates involved will not be appropriate for bicycle exercise. (Author)

  1. Cardiac pacing in heart failure patients with left bundle branch block: impact of pacing site for optimizing left ventricular resynchronization.

    Science.gov (United States)

    Pappone, C; Rosanio, S; Oreto, G; Tocchi, M; Gulletta, S; Salvati, A; Dicandia, C; Santinelli, V; Mazzone, P; Veglia, F; Ding, J; Sallusti, L; Spinelli, J; Vicedomini, G

    2000-07-01

    Acute left ventricular pacing has been associated with hemodynamic improvement in patients with congestive heart failure and wide QRS complex. We hypothesized that pacing two left ventricular sites simultaneously would produce faster activation and better systolic function than single-site pacing. We selected 14 heart failure patients (NYHA functional class III or IV) in normal sinus rhythm with left bundle branch block and QRS > 150 ms. An 8F dual micromanometer catheter was placed in the aorta for measuring +dP/dt (mmHg/s), aortic pulse pressure (mmHg), and end-diastolic pressure (mmHg). Pacing leads were positioned via coronary veins at the posterior base and lateral wall. Patients were acutely paced VDD at the posterior base, lateral wall, and both sites (dual-site) with 5 atrioventricular delays (from 8 ms to PR -30 ms). Pacing sequences were executed in randomized order using a custom external computer (FlexStim, Guidant CRM). Dual-site pacing increased peak +dP/dt significantly more than posterior base and lateral wall pacing. Dual-site and posterior base pacing raised aortic pulse pressure significantly more than lateral wall pacing. Dual-site pacing shortened QRS duration by 22 %, whereas posterior base and lateral wall pacing increased it by 2 and 12%, respectively (p = 0.006). In heart failure patients with left bundle branch block, dual-site pacing improves systolic function more than single-site stimulation. Improved ventricular activation synchrony, expressed by paced QRS narrowing, may account for the additional benefit of dual- vs single-site pacing in enhancing contractility. This novel approach deserves consideration for future heart failure pacing studies.

  2. The effect of metaprolol alone and metaprolol plus bromazepam on heart rate and heart rate variability during multislice computed tomography angiography

    International Nuclear Information System (INIS)

    Tuyyab, F.; Naeem, M.Y.; Maken, G.R.; Najfi, M.H.; Hassan, F.

    2012-01-01

    Objective: The purpose of this study was to determine the effect of metaprolol alone and metaprolol plus bromazepam on heart rate and heart rate variability during multi slice computed tomography (MSCT) angiography. Methodology: This was a Double blind randomized controlled trial was conducted at AFIC/NIHD, Rawalpindi, from May 2011 to November 2011. Patients undergoing first MSCT angiography meeting inclusion criteria with heart rates (HR) more than 80 beats/min were included. Patients were randomized in to two groups using random numbers table. Group 1 was administered metaprolol plus placebo while group 2 was administered metaprolol plus bromazepam one hour before the scan. Both groups had scans under strictly similar conditions. HR before and during scan along with heart rate variability (HRV) were recorded. Results: A total of 80 patients were included. Patients mean age was 49 + 13, 57 % were males while 43 % were females. Risk factor profile was similar in both groups. HR reduction in group 1 was 15+ 6.0 and in group 2, was 21+9.0 (p= 0.002). HRV in group 1 was 3.9 + 1.32 and in group 2 was 2.3 + 1.0 (p= 0.003). Group 2 had significantly lower HR and significantly less HRV as compared with group 1. Conclusion: Combination of bromazepam and metaprolol results in significant and further reduction in heart rate and heart rate variability than metaprolol alone. Both drugs can be used together for a better control of heart rate and heart rate variability during MSCT angiography for improving the quality of images. (author)

  3. Heating and cooling rates and their effects upon heart rate in the ...

    African Journals Online (AJOL)

    The heating and cooling rates of adult Chersina angulata were investigated to ascertain whether these tortoises can physiologically alter their rates of heat exchange. In addition, heart rates were recorded to provide an insight into the control of heat exchange. C. angulata heats significantly faster than it cools. Heart rates ...

  4. Hardware Implementation of a Modified Delay-Coordinate Mapping-Based QRS Complex Detection Algorithm

    Directory of Open Access Journals (Sweden)

    Andrej Zemva

    2007-01-01

    Full Text Available We present a modified delay-coordinate mapping-based QRS complex detection algorithm, suitable for hardware implementation. In the original algorithm, the phase-space portrait of an electrocardiogram signal is reconstructed in a two-dimensional plane using the method of delays. Geometrical properties of the obtained phase-space portrait are exploited for QRS complex detection. In our solution, a bandpass filter is used for ECG signal prefiltering and an improved method for detection threshold-level calculation is utilized. We developed the algorithm on the MIT-BIH Arrhythmia Database (sensitivity of 99.82% and positive predictivity of 99.82% and tested it on the long-term ST database (sensitivity of 99.72% and positive predictivity of 99.37%. Our algorithm outperforms several well-known QRS complex detection algorithms, including the original algorithm.

  5. Heart rate awareness in patients with chronic stable heart failure. A multi-center observational study.

    LENUS (Irish Health Repository)

    Moran, D

    2014-08-23

    We assessed adherence to European Society of Cardiology heart rate guidelines (i.e. heart rates less than 70bpm) in patients with chronic stable heart failure. We also investigated the percent of patients on target doses of rate controlling drugs.

  6. The mitochondrial uniporter controls fight or flight heart rate increases.

    Science.gov (United States)

    Wu, Yuejin; Rasmussen, Tyler P; Koval, Olha M; Joiner, Mei-Ling A; Hall, Duane D; Chen, Biyi; Luczak, Elizabeth D; Wang, Qiongling; Rokita, Adam G; Wehrens, Xander H T; Song, Long-Sheng; Anderson, Mark E

    2015-01-20

    Heart rate increases are a fundamental adaptation to physiological stress, while inappropriate heart rate increases are resistant to current therapies. However, the metabolic mechanisms driving heart rate acceleration in cardiac pacemaker cells remain incompletely understood. The mitochondrial calcium uniporter (MCU) facilitates calcium entry into the mitochondrial matrix to stimulate metabolism. We developed mice with myocardial MCU inhibition by transgenic expression of a dominant-negative (DN) MCU. Here, we show that DN-MCU mice had normal resting heart rates but were incapable of physiological fight or flight heart rate acceleration. We found that MCU function was essential for rapidly increasing mitochondrial calcium in pacemaker cells and that MCU-enhanced oxidative phoshorylation was required to accelerate reloading of an intracellular calcium compartment before each heartbeat. Our findings show that MCU is necessary for complete physiological heart rate acceleration and suggest that MCU inhibition could reduce inappropriate heart rate increases without affecting resting heart rate.

  7. PKPD modelling of PR and QRS intervals in conscious dogs using standard safety pharmacology data.

    Science.gov (United States)

    Bergenholm, Linnéa; Collins, Teresa; Evans, Neil D; Chappell, Michael J; Parkinson, Joanna

    2016-01-01

    Pharmacokinetic-pharmacodynamic (PKPD) modelling can improve safety assessment, but few PKPD models describing drug-induced QRS and PR prolongations have been published. This investigation aims to develop and evaluate PKPD models for describing QRS and PR effects in routine safety studies. Exposure and telemetry data from safety pharmacology studies in conscious beagle dogs were acquired. Mixed effects baseline and PK-QRS/PR models were developed for the anti-arrhythmic compounds AZD1305, flecainide, quinidine and verapamil and the anti-muscarinic compounds AZD8683 and AZD9164. RR interval correction and circadian rhythms were investigated for predicting baseline variability. Individual PK predictions were used to drive the pharmacological effects evaluating linear and non-linear direct and effect compartment models. Conduction slowing induced by the tested anti-arrhythmics was direct and proportional at low exposures, whilst time delays and non-linear effects were evident for the tested anti-muscarinics. AZD1305, flecainide and quinidine induced QRS widening with 4.2, 10 and 5.6% μM(-1) unbound drug. AZD1305 and flecainide also prolonged PR with 13.5 and 11.5% μM(-1). PR prolongations induced by the anti-muscarinics and verapamil were best described by Emax models with maximal effects ranging from 55 to 95%. RR interval correction and circadian rhythm improved PR but not QRS modelling. However, circadian rhythm had minor impact on estimated drug effects. Baseline and drug-induced effects on QRS and PR intervals can be effectively described with PKPD models using routine data, providing quantitative safety information to support drug discovery and development. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Arduino-based noise robust online heart-rate detection.

    Science.gov (United States)

    Das, Sangita; Pal, Saurabh; Mitra, Madhuchhanda

    2017-04-01

    This paper introduces a noise robust real time heart rate detection system from electrocardiogram (ECG) data. An online data acquisition system is developed to collect ECG signals from human subjects. Heart rate is detected using window-based autocorrelation peak localisation technique. A low-cost Arduino UNO board is used to implement the complete automated process. The performance of the system is compared with PC-based heart rate detection technique. Accuracy of the system is validated through simulated noisy ECG data with various levels of signal to noise ratio (SNR). The mean percentage error of detected heart rate is found to be 0.72% for the noisy database with five different noise levels.

  9. QRS detection based ECG quality assessment

    International Nuclear Information System (INIS)

    Hayn, Dieter; Jammerbund, Bernhard; Schreier, Günter

    2012-01-01

    Although immediate feedback concerning ECG signal quality during recording is useful, up to now not much literature describing quality measures is available. We have implemented and evaluated four ECG quality measures. Empty lead criterion (A), spike detection criterion (B) and lead crossing point criterion (C) were calculated from basic signal properties. Measure D quantified the robustness of QRS detection when applied to the signal. An advanced Matlab-based algorithm combining all four measures and a simplified algorithm for Android platforms, excluding measure D, were developed. Both algorithms were evaluated by taking part in the Computing in Cardiology Challenge 2011. Each measure's accuracy and computing time was evaluated separately. During the challenge, the advanced algorithm correctly classified 93.3% of the ECGs in the training-set and 91.6 % in the test-set. Scores for the simplified algorithm were 0.834 in event 2 and 0.873 in event 3. Computing time for measure D was almost five times higher than for other measures. Required accuracy levels depend on the application and are related to computing time. While our simplified algorithm may be accurate for real-time feedback during ECG self-recordings, QRS detection based measures can further increase the performance if sufficient computing power is available. (paper)

  10. Correlation of QRS complex after percutaneous coronary intervention with myocardial ischemia reperfusion injury and apoptosis molecule contents

    Directory of Open Access Journals (Sweden)

    Ming-Min Jiang

    2017-11-01

    Full Text Available Objective: To study the correlation of QRS complex after percutaneous coronary intervention (PCI with myocardial ischemia reperfusion injury and apoptosis molecule contents. Methods: Patients with non-ST-segment elevation myocardial infarction who were treated in Nanchong Central Hospital between June 2014 and August 2016 were selected and divided into the PCI group who received emergency PCI surgery and the control group who accepted selective PCI or refused emergency PCI after the medical data were retrospectively analyzed. The fQRS as well as the contents of ischemia reperfusion injury indexes and apoptosis molecules was determined after 1 week of treatment. Results: The incidence of fQRS in PCI group was significantly lower than that in control group; serum MDA, cTnI, H-FABP, sTWEAK, sFas, sTRAIL and Caspase-3 contents as well as peripheral blood Nrf-2 and HO-1 expression of PCI group were greatly lower than those of control group; serum MDA, cTnI, H-FABP, sTWEAK, sFas, sTRAIL and Caspase-3 contents as well as peripheral blood Nrf-2 and HO-1 expression of PCI group of patients with fQRS complex (+ were greatly higher than those of patients with fQRS complex (-. Conclusion: The occurrence of fQRS after PCI is closely related to myocardial ischemia reperfusion injury and apoptosis.

  11. Heart rate variability interventions for concussion and rehabilitation

    OpenAIRE

    Conder, Robert L.; Conder, Alanna A.

    2014-01-01

    The study of Heart Rate Variability (HRV) has emerged as an essential component of cardiovascular health, as well as a physiological mechanism by which one can increase the interactive communication between the cardiac and the neurocognitive systems (i.e., the body and the brain). It is well-established that lack of heart rate variability implies cardiopathology, morbidity, reduced quality-of-life, and precipitous mortality. On the positive, optimal heart rate variability has been associated ...

  12. When Deriving the Spatial QRS-T Angle from the 12-lead ECG, which Transform is More Frank: Regression or Inverse Dower?

    Science.gov (United States)

    Schlegel, Todd T.; Cortez, Daniel

    2010-01-01

    Our primary objective was to ascertain which commonly used 12-to-Frank-lead transformation yields spatial QRS-T angle values closest to those obtained from simultaneously collected true Frank-lead recordings. Simultaneous 12-lead and Frank XYZ-lead recordings were analyzed for 100 post-myocardial infarction patients and 50 controls. Relative agreement, with true Frank-lead results, of 12-to-Frank-lead transformed results for the spatial QRS-T angle using Kors regression versus inverse Dower was assessed via ANOVA, Lin s concordance and Bland-Altman plots. Spatial QRS-T angles from the true Frank leads were not significantly different than those derived from the Kors regression-related transformation but were significantly smaller than those derived from the inverse Dower-related transformation (P less than 0.001). Independent of method, spatial mean QRS-T angles were also always significantly larger than spatial maximum (peaks) QRS-T angles. Spatial QRS-T angles are best approximated by regression-related transforms. Spatial mean and spatial peaks QRS-T angles should also not be used interchangeably.

  13. Scoring system based on electrocardiogram features to predict the type of heart failure in patients with chronic heart failure

    Directory of Open Access Journals (Sweden)

    Hendry Purnasidha Bagaswoto

    2016-12-01

    Full Text Available ABSTRACT Heart failure is divided into heart failure with reduced ejection fraction (HFrEF and heart failure with preserved ejection fraction (HFpEF. Additional studies are required to distinguish between these two types of HF. A previous study showed that HFrEF is less likely when ECG findings are normal. This study aims to create a scoring system based on ECG findings that will predict the type of HF. We performed a cross-sectional study analyzing ECG and echocardiographic data from 110 subjects. HFrEF was defined as an ejection fraction ≤40%. Fifty people were diagnosed with HFpEF and 60 people suffered from HFrEF. Multiple logistic regression analysis revealed certain ECG variables that were independent predictors of HFrEF i.e., LAH, QRS duration >100 ms, RBBB, ST-T segment changes and prolongation of the QT interval. Based on ROC curve analysis, we obtained a score for HFpEF of -1 to +3, while HFrEF had a score of +4 to +6 with 76% sensitivity, 96% specificity, 95% positive predictive value, an 80% negative predictive value and an accuracy of 86%. The scoring system derived from this study, including the presence or absence of LAH, QRS duration >100 ms, RBBB, ST-T segment changes and prolongation of the QT interval can be used to predict the type of HF with satisfactory sensitivity and specificity

  14. Heart Rate Monitoring in Team Sports—A Conceptual Framework for Contextualizing Heart Rate Measures for Training and Recovery Prescription

    Directory of Open Access Journals (Sweden)

    Christoph Schneider

    2018-05-01

    Full Text Available A comprehensive monitoring of fitness, fatigue, and performance is crucial for understanding an athlete's individual responses to training to optimize the scheduling of training and recovery strategies. Resting and exercise-related heart rate measures have received growing interest in recent decades and are considered potentially useful within multivariate response monitoring, as they provide non-invasive and time-efficient insights into the status of the autonomic nervous system (ANS and aerobic fitness. In team sports, the practical implementation of athlete monitoring systems poses a particular challenge due to the complex and multidimensional structure of game demands and player and team performance, as well as logistic reasons, such as the typically large number of players and busy training and competition schedules. In this regard, exercise-related heart rate measures are likely the most applicable markers, as they can be routinely assessed during warm-ups using short (3–5 min submaximal exercise protocols for an entire squad with common chest strap-based team monitoring devices. However, a comprehensive and meaningful monitoring of the training process requires the accurate separation of various types of responses, such as strain, recovery, and adaptation, which may all affect heart rate measures. Therefore, additional information on the training context (such as the training phase, training load, and intensity distribution combined with multivariate analysis, which includes markers of (perceived wellness and fatigue, should be considered when interpreting changes in heart rate indices. The aim of this article is to outline current limitations of heart rate monitoring, discuss methodological considerations of univariate and multivariate approaches, illustrate the influence of different analytical concepts on assessing meaningful changes in heart rate responses, and provide case examples for contextualizing heart rate measures using

  15. Heart Rate Monitoring in Team Sports-A Conceptual Framework for Contextualizing Heart Rate Measures for Training and Recovery Prescription.

    Science.gov (United States)

    Schneider, Christoph; Hanakam, Florian; Wiewelhove, Thimo; Döweling, Alexander; Kellmann, Michael; Meyer, Tim; Pfeiffer, Mark; Ferrauti, Alexander

    2018-01-01

    A comprehensive monitoring of fitness, fatigue, and performance is crucial for understanding an athlete's individual responses to training to optimize the scheduling of training and recovery strategies. Resting and exercise-related heart rate measures have received growing interest in recent decades and are considered potentially useful within multivariate response monitoring, as they provide non-invasive and time-efficient insights into the status of the autonomic nervous system (ANS) and aerobic fitness. In team sports, the practical implementation of athlete monitoring systems poses a particular challenge due to the complex and multidimensional structure of game demands and player and team performance, as well as logistic reasons, such as the typically large number of players and busy training and competition schedules. In this regard, exercise-related heart rate measures are likely the most applicable markers, as they can be routinely assessed during warm-ups using short (3-5 min) submaximal exercise protocols for an entire squad with common chest strap-based team monitoring devices. However, a comprehensive and meaningful monitoring of the training process requires the accurate separation of various types of responses, such as strain, recovery, and adaptation, which may all affect heart rate measures. Therefore, additional information on the training context (such as the training phase, training load, and intensity distribution) combined with multivariate analysis, which includes markers of (perceived) wellness and fatigue, should be considered when interpreting changes in heart rate indices. The aim of this article is to outline current limitations of heart rate monitoring, discuss methodological considerations of univariate and multivariate approaches, illustrate the influence of different analytical concepts on assessing meaningful changes in heart rate responses, and provide case examples for contextualizing heart rate measures using simple heuristics. To

  16. Data on association between QRS duration on prehospital ECG and mortality in patients with confirmed STEMI

    DEFF Research Database (Denmark)

    Hansen, Rikke; Frydland, Martin; Møller-Helgestad, Ole Kristian

    2017-01-01

    Data presented in this article relates to the research article entitled “Association between QRS duration on prehospital ECG and mortality in patients with suspected STEMI” (Hansen et al., in press) [1]. Data on the prognostic effect of automatically recoded QRS duration on prehospital ECG...

  17. Heart rate measurement based on face video sequence

    Science.gov (United States)

    Xu, Fang; Zhou, Qin-Wu; Wu, Peng; Chen, Xing; Yang, Xiaofeng; Yan, Hong-jian

    2015-03-01

    This paper proposes a new non-contact heart rate measurement method based on photoplethysmography (PPG) theory. With this method we can measure heart rate remotely with a camera and ambient light. We collected video sequences of subjects, and detected remote PPG signals through video sequences. Remote PPG signals were analyzed with two methods, Blind Source Separation Technology (BSST) and Cross Spectral Power Technology (CSPT). BSST is a commonly used method, and CSPT is used for the first time in the study of remote PPG signals in this paper. Both of the methods can acquire heart rate, but compared with BSST, CSPT has clearer physical meaning, and the computational complexity of CSPT is lower than that of BSST. Our work shows that heart rates detected by CSPT method have good consistency with the heart rates measured by a finger clip oximeter. With good accuracy and low computational complexity, the CSPT method has a good prospect for the application in the field of home medical devices and mobile health devices.

  18. Power spectral analysis of heart rate in hyperthyroidism.

    Science.gov (United States)

    Cacciatori, V; Bellavere, F; Pezzarossa, A; Dellera, A; Gemma, M L; Thomaseth, K; Castello, R; Moghetti, P; Muggeo, M

    1996-08-01

    The aim of the present study was to evaluate the impact of hyperthyroidism on the cardiovascular system by separately analyzing the sympathetic and parasympathetic influences on heart rate. Heart rate variability was evaluated by autoregressive power spectral analysis. This method allows a reliable quantification of the low frequency (LF) and high frequency (HF) components of the heart rate power spectral density; these are considered to be under mainly sympathetic and pure parasympathetic control, respectively. In 10 newly diagnosed untreated hyperthyroid patients with Graves' disease, we analyzed power spectral density of heart rate cyclic variations at rest, while lying, and while standing. In addition, heart rate variations during deep breathing, lying and standing, and Valsalva's maneuver were analyzed. The results were compared to those obtained from 10 age-, sex-, and body mass index-matched control subjects. In 8 hyperthyroid patients, the same evaluation was repeated after the induction of stable euthyroidism by methimazole. Heart rate power spectral analysis showed a sharp reduction of HF components in hyperthyroid subjects compared to controls [lying, 13.3 +/- 4.1 vs. 32.0 +/- 5.6 normalized units (NU; P hyperthyroid subjects while both lying (11.3 +/- 4.5 vs. 3.5 +/- 1.1; P hyperthyroid patients than in controls (1.12 +/- 0.03 vs. 1.31 +/- 0.04; P activity and, thus, a relative hypersympathetic tone.

  19. Heart rate response to hypoxic exercise

    DEFF Research Database (Denmark)

    Lundby, C; Møller, P; Kanstrup, I L

    2001-01-01

    progressively decreased the maximal heart rate from day 1 and onwards; also, hypoxia by itself increased plasma noradrenaline levels after maximal exercise. Domperidone further increased maximal noradrenaline concentrations, but had no effect on maximal heart rate. On each study day at altitude, oxygen......This study examined the effects of dopamine D(2)-receptor blockade on the early decrease in maximal heart rate at high altitude (4559 m). We also attempted to clarify the time-dependent component of this reduction and the extent to which it is reversed by oxygen breathing. Twelve subjects performed...... two consecutive maximal exercise tests, without and with oxygen supplementation respectively, at sea level and after 1, 3 and 5 days at altitude. On each study day, domperidone (30 mg; n=6) or no medication (n=6) was given 1 h before the first exercise session. Compared with sea level, hypoxia...

  20. Case report: an unstable wide QRS complexes tachycardia after ablation of a poster-septal accessory pathway: What is the mechanism?

    Science.gov (United States)

    Wang, Huan; Che, Xiaoru

    2018-03-01

    Differentiation of wide QRS complex tachycardia required repeated electrophysiological stimuli and mapping. However, instability of tachycardia would increase the difficulty in differential diagnosis. In this paper, we reported a wide QRS tachycardia following ablation of an atrioventricular reentrant tachycardia participated by a poster-septal accessory pathway. Limited differentiation strategy was performed because the wide QRS tachycardia was self-limited and with unstable hemodynamics. We analyzed the mechanism of the wide QRS tachycardia by only 4 beats ventricular overpacing. On the basis of the last ventricular pacing, an atypical atrioventricular nodal reentrant tachycardia was confirmed. After slow-pathway modification, the wide QRS tachycardia was eliminated. It was an atypical atrial-ventricular node reentrant tachycardia with right bundle branch block. Reasonable analysis based on electrophysiological electrophysiologic knowledge was the basis of successful diagnosis and treatment.

  1. The heart field effect: Synchronization of healer-subject heart rates in energy therapy.

    Science.gov (United States)

    Bair, Christine Caldwell

    2008-01-01

    Recent health research has focused on subtle energy and vibrational frequency as key components of health and healing. In particular, intentional direction of bioenergy is receiving increasing scientific attention. This study investigates the effect of the healer's electromagnetic (EM) heart field upon subjects during energy healing as measured by synchronization of heart rates and scores on a Subjective Units of Distress (SUD) scale and a Profile of Mood States (POMS) inventory. A nonequivalent pretest-posttest design was used based on heart rate comparisons between healer and subject and correlated with pre-and posttest SUD and POMS scores. Subjects included those who sat within the 3- to 4-foot "strong" range of the independent variable, the healer's heart field, while performing self-application of WHEE (the wholistic hybrid derived from EMDR [eye movement desensitization and reprocessing], and EFT [emotional freedom technique]), a meridian-based tapping technique (n=50); and those who performed the same process beyond the 15- to 18-foot range of the healer's EM heart field (n=41). The dependent variables were heart rate, SUD, and POMS inventory. All subjects completed these measures within 1 hour. Study results showed statistically significant heart-rate synchronization with the intervention population. In addition, SUD and POMS scores demonstrated considerably more improvement than in the control population, indicating additional benefit beyond the meridian-based therapies, such as WHEE, alone. Additional findings and future research recommendations are presented in this article.

  2. Learning by Heart: Students Use Heart Rate Patterns To Identify Nervous System Imbalances.

    Science.gov (United States)

    Ackerly, Spafford C.

    2001-01-01

    Introduces a science unit on heart rate variability (HVR) patterns. Uses spectral analysis to determine the effects of environmental stimulants such as music and emotional stress on heart rate. Observes relaxation techniques and their effects on the autonomous nervous system. (Contains 12 references.) (YDS)

  3. [Resonance hypothesis of heart rate variability origin].

    Science.gov (United States)

    Sheĭkh-Zade, Iu R; Mukhambetaliev, G Kh; Cherednik, I L

    2009-09-01

    A hypothesis is advanced of the heart rate variability being subjected to beat-to-beat regulation of cardiac cycle duration in order to ensure the resonance interaction between respiratory and own fluctuation of the arterial system volume for minimization of power expenses of cardiorespiratory system. Myogenic, parasympathetic and sympathetic machanisms of heart rate variability are described.

  4. Device therapy in heart failure with reduced ejection fraction-cardiac resynchronization therapy and more.

    Science.gov (United States)

    Duncker, D; Veltmann, C

    2018-05-09

    In patients with heart failure with reduced ejection fraction (HFrEF), optimal medical treatment includes beta-blockers, ACE inhibitors/angiotensinreceptor-neprilysin inhibitors (ARNI), mineralocorticoid receptor antagonists, and ivabradine when indicated. In device therapy of HFrEF, implantable cardioverter-defibrillators and cardiac resynchronization therapy (CRT) have been established for many years. CRT is the therapy of choice (class I indication) in symptomatic patients with HFrEF and a broad QRS complex with a left bundle branch block (LBBB) morphology. However, the vast majority of heart failure patients show a narrow QRS complex or a non-LBBB morphology. These patients are not candidates for CRT and alternative electrical therapies such as baroreflex activation therapy (BAT) and cardiac contractility modulation (CCM) may be considered. BAT modulates vegetative dysregulation in heart failure. CCM improves contractility, functional capacity, and symptoms. Although a broad data set is available for BAT and CCM, mortality data are still lacking for both methods. This article provides an overview of the device-based therapeutic options for patients with HFrEF.

  5. Accuracy of Heart Rate Watches: Implications for Weight Management.

    Directory of Open Access Journals (Sweden)

    Matthew P Wallen

    Full Text Available Wrist-worn monitors claim to provide accurate measures of heart rate and energy expenditure. People wishing to lose weight use these devices to monitor energy balance, however the accuracy of these devices to measure such parameters has not been established.To determine the accuracy of four wrist-worn devices (Apple Watch, Fitbit Charge HR, Samsung Gear S and Mio Alpha to measure heart rate and energy expenditure at rest and during exercise.Twenty-two healthy volunteers (50% female; aged 24 ± 5.6 years completed ~1-hr protocols involving supine and seated rest, walking and running on a treadmill and cycling on an ergometer. Data from the devices collected during the protocol were compared with reference methods: electrocardiography (heart rate and indirect calorimetry (energy expenditure.None of the devices performed significantly better overall, however heart rate was consistently more accurate than energy expenditure across all four devices. Correlations between the devices and reference methods were moderate to strong for heart rate (0.67-0.95 [0.35 to 0.98] and weak to strong for energy expenditure (0.16-0.86 [-0.25 to 0.95]. All devices underestimated both outcomes compared to reference methods. The percentage error for heart rate was small across the devices (range: 1-9% but greater for energy expenditure (9-43%. Similarly, limits of agreement were considerably narrower for heart rate (ranging from -27.3 to 13.1 bpm than energy expenditure (ranging from -266.7 to 65.7 kcals across devices.These devices accurately measure heart rate. However, estimates of energy expenditure are poor and would have implications for people using these devices for weight loss.

  6. Accuracy of Heart Rate Watches: Implications for Weight Management.

    Science.gov (United States)

    Wallen, Matthew P; Gomersall, Sjaan R; Keating, Shelley E; Wisløff, Ulrik; Coombes, Jeff S

    2016-01-01

    Wrist-worn monitors claim to provide accurate measures of heart rate and energy expenditure. People wishing to lose weight use these devices to monitor energy balance, however the accuracy of these devices to measure such parameters has not been established. To determine the accuracy of four wrist-worn devices (Apple Watch, Fitbit Charge HR, Samsung Gear S and Mio Alpha) to measure heart rate and energy expenditure at rest and during exercise. Twenty-two healthy volunteers (50% female; aged 24 ± 5.6 years) completed ~1-hr protocols involving supine and seated rest, walking and running on a treadmill and cycling on an ergometer. Data from the devices collected during the protocol were compared with reference methods: electrocardiography (heart rate) and indirect calorimetry (energy expenditure). None of the devices performed significantly better overall, however heart rate was consistently more accurate than energy expenditure across all four devices. Correlations between the devices and reference methods were moderate to strong for heart rate (0.67-0.95 [0.35 to 0.98]) and weak to strong for energy expenditure (0.16-0.86 [-0.25 to 0.95]). All devices underestimated both outcomes compared to reference methods. The percentage error for heart rate was small across the devices (range: 1-9%) but greater for energy expenditure (9-43%). Similarly, limits of agreement were considerably narrower for heart rate (ranging from -27.3 to 13.1 bpm) than energy expenditure (ranging from -266.7 to 65.7 kcals) across devices. These devices accurately measure heart rate. However, estimates of energy expenditure are poor and would have implications for people using these devices for weight loss.

  7. Long-term mortality risk in patients with an implantable cardioverter-defibrillator

    DEFF Research Database (Denmark)

    Hoogwegt, Madelein T; Theuns, Dominic A M J; Pedersen, Susanne S.

    2014-01-01

    .9)). The impact of heart rate and QRS duration on time to all-cause mortality was separately assessed with Cox proportional hazard regression analysis, adjusting for clinical factors and symptoms of depression and anxiety. RESULTS: Mean (SD) heart rate was 68.0 ± 13.3 bpm and mean QRS duration was 130.9 ± 36.9 ms....... Heart rate of ≥80 bpm was associated with increased risk of mortality (HR=1.86; 95% CI=1.15-3.00; p=.011) in unadjusted analysis. In adjusted analyses, this relationship remained significant both with depression (HR=1.86, 95% CI=1.12-3.09; p=.017) and anxiety (HR=1.82, 95% CI=1.10-3.03; p=.021...

  8. Simultaneous measurement of instantaneous heart rate and chest wall plethysmography in short-term, metronome guided heart rate variability studies: suitability for assessment of autonomic dysfunction.

    Science.gov (United States)

    Perring, S; Jones, E

    2003-08-01

    Instantaneous heart rate and chest wall motion were measured using a 3-lead ECG and an air pressure chest wall plethysmography system. Chest wall plethysmography traces were found to accurately represent the breathing pattern as measured by spirometry (average correlation coefficient 0.944); though no attempt was made to calibrate plethysmography voltage output to tidal volume. Simultaneous measurements of heart rate and chest wall motion were made for short periods under metronome guided breathing at 6 breaths per minute. The average peak to trough heart rate change per breath cycle (AVEMAX) and maximum correlation between heart rate and breathing cycle (HRBRCORR) were measured. Studies of 44 normal volunteers indicated clear inverse correlation of heart rate variability parameters with age (AVEMAX R = -0.502, P < 0.001) but no significant change in HRBRCORR with age (R = -0.115). Comparison of normal volunteers with diabetics with no history of symptoms associated with autonomic failure indicated significant lower heart rate variability in diabetics (P = 0.005 for AVEMAX) and significantly worse correlation between heart rate and breathing (P < 0.001 for HRBRCORR). Simultaneous measurement of heart rate and breathing offers the possibility of more sensitive diagnosis of autonomic failure in a simple bedside test and gives further insight into the nature of cardio-ventilatory coupling.

  9. Electrocardiographic Findings in Brazilian Adults without Heart Disease: ELSA-Brasil.

    Science.gov (United States)

    Pinto, Marcelo Martins; Brant, Luisa C C; Padilha-da-Silva, José Luiz; Foppa, Murilo; Lotufo, Paulo A; Mill, José Geraldo; Vasconcelo-Silva, Paulo R; Almeida, Maria da Conceição C; Barreto, Sandhi Maria; Ribeiro, Antônio Luiz Pinho

    2017-11-01

    The electrocardiogram (ECG) is widely used in population-based studies. However, there are few studies on electrocardiographic findings in Latin America and in Brazil. The Brazilian Longitudinal Study of Adult Health (ELSA-Brasil) comprised 15,105 participants (35-74 years) from six Brazilian capitals. To describe electrocardiographic findings in Brazilian adults without heart disease, stratified by sex, age and race/skin color. Cross-sectional study with baseline data of 11,094 adults (44.5% men) without heart disease from ELSA-Brasil. The ECGs were recorded with the Burdick Atria 6100 machine and stored at the Pyramis System. ECG analysis was automatically performed using the Glasgow University software. A descriptive analysis of heart rate (HR), P, QRS and T waves' duration, PR and QT intervals, and P, R and T axes was performed. After stratification by sex, race/color and age, the groups were compared by the Wilcoxon and Kruskal-Wallis test at a significance level of 5%. Linear regression models were used to evaluate the behavior of electrocardiographic parameters over age. Major electrocardiographic abnormalities defined by the Minnesota code were manually revised. Medians values of the electrocardiographic parameters were different between men and women: HR 63 vs. 66 bpm, PR 164 vs.158 ms, QT corrected 410 vs. 421 ms, QRS duration 92 vs. 86 ms, P-wave duration 112 vs. 108 ms, P-wave axis 54 vs. 57 degrees, R-wave axis 35 vs. 39 degrees, T-wave axis 39 vs. 45 degrees (p < 0.001 for all). The 2nd and the 98th percentiles of each variable were also obtained, and graphs were constructed to illustrate the behavior of the electrocardiographic findings over age of participants stratified by sex and race/skin color. The values for the electrocardiographic measurements herein described can be used as reference for Brazilian adults free of heart disease, stratified by sex. Our results suggest that self-reported race/skin color have no significant influence on

  10. Electrocardiogram of Clinically Healthy Mithun (Bos frontalis): Variation among Strains

    Science.gov (United States)

    Sanyal, Sagar; Das, Pradip Kumar; Ghosh, Probal Ranjan; Das, Kinsuk; Vupru, Kezha V.; Rajkhowa, Chandan; Mondal, Mohan

    2010-01-01

    A study was conducted to establish the normal electrocardiogram in four different genetic strains of mithun (Bos frontalis). Electrocardiography, cardiac electrical axis, heart rate, rectal temperature and respiration rate were recorded in a total of 32 adult male mithun of four strains (n = 8 each). It was found that the respiration and heart rates were higher (P electrocardiogram of mithun revealed that the amplitude and duration of P wave, QRS complex and T wave were different among four different genetic strains of mithun and the electrical axis of QRS complex for Nagamese and Mizoram mithuns are dissimilar to bovine species. PMID:20886013

  11. Cardiac conductive disturbance in patients with polycystic ovary syndrome.

    Science.gov (United States)

    Huang, Jen-Hung; Tsai, Jen-Chen; Hsu, Ming-I; Chen, Yi-Jen

    2010-12-01

    Polycystic ovary syndrome (PCOS) is the most common endocrine abnormality of reproductive-aged women and increases the risk of cardiovascular disease. However, the effects of PCOS on electrocardiograms (ECGs) are not fully elucidated. The aim of this study was to evaluate the characteristics of ECGs in patients with PCOS. This study included 24 patients with PCOS and 12 patients without PCOS. The heart rate, PR interval, QRS duration, Sokolow-Lyon voltage (SV1 + RV5/6), Cornell voltage (RaVL + SV3), QT interval and QTc interval were measured in 12-lead ECGs. The QRS duration was wider in patients with PCOS than those without PCOS (91 ± 8 vs. 81 ± 10 ms, p heart rate, PR interval, Sokolow-Lyon voltage, product of the QRS duration times Cornell voltage combination, QT interval, QTc interval, QT dispersion and QTc dispersion were similar between the two groups. PCOS is associated with a widening QRS duration, which may contribute to its increased cardiovascular risks.

  12. Heart Rate Fragmentation: A Symbolic Dynamical Approach

    Directory of Open Access Journals (Sweden)

    Madalena D. Costa

    2017-11-01

    Full Text Available Background: We recently introduced the concept of heart rate fragmentation along with a set of metrics for its quantification. The term was coined to refer to an increase in the percentage of changes in heart rate acceleration sign, a dynamical marker of a type of anomalous variability. The effort was motivated by the observation that fragmentation, which is consistent with the breakdown of the neuroautonomic-electrophysiologic control system of the sino-atrial node, could confound traditional short-term analysis of heart rate variability.Objective: The objectives of this study were to: (1 introduce a symbolic dynamical approach to the problem of quantifying heart rate fragmentation; (2 evaluate how the distribution of the different dynamical patterns (“words” varied with the participants' age in a group of healthy subjects and patients with coronary artery disease (CAD; and (3 quantify the differences in the fragmentation patterns between the two sample populations.Methods: The symbolic dynamical method employed here was based on a ternary map of the increment NN interval time series and on the analysis of the relative frequency of symbolic sequences (words with a pre-defined set of features. We analyzed annotated, open-access Holter databases of healthy subjects and patients with CAD, provided by the University of Rochester Telemetric and Holter ECG Warehouse (THEW.Results: The degree of fragmentation was significantly higher in older individuals than in their younger counterparts. However, the fragmentation patterns were different in the two sample populations. In healthy subjects, older age was significantly associated with a higher percentage of transitions from acceleration/deceleration to zero acceleration and vice versa (termed “soft” inflection points. In patients with CAD, older age was also significantly associated with higher percentages of frank reversals in heart rate acceleration (transitions from acceleration to

  13. Heart rate variability - a historical perspective.

    Science.gov (United States)

    Billman, George E

    2011-01-01

    Heart rate variability (HRV), the beat-to-beat variation in either heart rate or the duration of the R-R interval - the heart period, has become a popular clinical and investigational tool. The temporal fluctuations in heart rate exhibit a marked synchrony with respiration (increasing during inspiration and decreasing during expiration - the so called respiratory sinus arrhythmia, RSA) and are widely believed to reflect changes in cardiac autonomic regulation. Although the exact contributions of the parasympathetic and the sympathetic divisions of the autonomic nervous system to this variability are controversial and remain the subject of active investigation and debate, a number of time and frequency domain techniques have been developed to provide insight into cardiac autonomic regulation in both health and disease. It is the purpose of this essay to provide an historical overview of the evolution in the concept of HRV. Briefly, pulse rate was first measured by ancient Greek physicians and scientists. However, it was not until the invention of the "Physician's Pulse Watch" (a watch with a second hand that could be stopped) in 1707 that changes in pulse rate could be accurately assessed. The Rev. Stephen Hales (1733) was the first to note that pulse varied with respiration and in 1847 Carl Ludwig was the first to record RSA. With the measurement of the ECG (1895) and advent of digital signal processing techniques in the 1960s, investigation of HRV and its relationship to health and disease has exploded. This essay will conclude with a brief description of time domain, frequency domain, and non-linear dynamic analysis techniques (and their limitations) that are commonly used to measure HRV.

  14. Monitoring nocturnal heart rate with bed sensor.

    Science.gov (United States)

    Migliorini, M; Kortelainen, J M; Pärkkä, J; Tenhunen, M; Himanen, S L; Bianchi, A M

    2014-01-01

    This article is part of the Focus Theme of Methods of Information in Medicine on "Biosignal Interpretation: Advanced Methods for Studying Cardiovascular and Respiratory Systems". The aim of this study is to assess the reliability of the estimated Nocturnal Heart Rate (HR), recorded through a bed sensor, compared with the one obtained from standard electrocardiography (ECG). Twenty-eight sleep deprived patients were recorded for one night each through matrix of piezoelectric sensors, integrated into the mattress, through polysomnography (PSG) simultaneously. The two recording methods have been compared in terms of signal quality and differences in heart beat detection. On average, coverage of 92.7% of the total sleep time was obtained for the bed sensor, testifying the good quality of the recordings. The average beat-to-beat error of the inter-beat intervals was 1.06%. These results suggest a good overall signal quality, however, considering fast heart rates (HR > 100 bpm), performances were worse: in fact, the sensitivity in the heart beat detection was 28.4% while the false positive rate was 3.8% which means that a large amount of fast beats were not detected. The accuracy of the measurements made using the bed sensor has less than 10% of failure rate especially in periods with HR lower than 70 bpm. For fast heart beats the uncertainty increases. This can be explained by the change in morphology of the bed sensor signal in correspondence of a higher HR.

  15. Real-time QRS detection using integrated variance for ECG gated cardiac MRI

    Directory of Open Access Journals (Sweden)

    Schmidt Marcus

    2016-09-01

    Full Text Available During magnetic resonance imaging (MRI, a patient’s vital signs are required for different purposes. In cardiac MRI (CMR, an electrocardiogram (ECG of the patient is required for triggering the image acquisition process. However, a reliable QRS detection of an ECG signal acquired inside an MRI scanner is a challenging task due to the magnetohydrodynamic (MHD effect which interferes with the ECG. The aim of this work was to develop a reliable QRS detector usable inside the MRI which also fulfills the standards for medical devices (IEC 60601-2-27. Therefore, a novel real-time QRS detector based on integrated variance measurements is presented. The algorithm was trained on ANSI/AAMI EC13 test waveforms and was then applied to two databases with 12-lead ECG signals recorded inside and outside an MRI scanner. Reliable results for both databases were achieved for the ECG signals recorded inside (DBMRI: sensitivity Se = 99.94%, positive predictive value +P = 99.84% and outside (DBInCarT: Se = 99.29%, +P = 99.72% the MRI. Due to the accurate R-peak detection in real-time this can be used for monitoring and triggering in MRI exams.

  16. Influence of heavy cigarette smoking on heart rate variability and heart rate turbulence parameters

    DEFF Research Database (Denmark)

    Cagirci, Goksel; Cay, Serkan; Karakurt, Ozlem

    2009-01-01

    BACKGROUND: Cigarette smoking increases the risk of cardiovascular events related with several mechanisms. The most suggested mechanism is increased activity of sympathetic nervous system. Heart rate variability (HRV) and heart rate turbulence (HRT) has been shown to be independent and powerful......, 69 subjects and nonsmokers 74 subjects (control group) were enrolled in this study. HRV and HRT analyses [turbulence onset (TO) and turbulence slope (TS)] were assessed from 24-hour Holter recordings. RESULTS: The values of TO were significantly higher in heavy cigarette smokers than control group...... (-1.150 +/- 4.007 vs -2.454 +/- 2.796, P = 0.025, respectively), but values of TS were not statistically different between two groups (10.352 +/- 7.670 vs 9.613 +/- 7.245, P = 0.555, respectively). Also, the number of patients who had abnormal TO was significantly higher in heavy cigarette smokers...

  17. Significance of fragmented QRS complexes for identifying culprit lesions in patients with non-ST-elevation myocardial infarction: a single-center, retrospective analysis of 183 cases

    Directory of Open Access Journals (Sweden)

    Guo Rong

    2012-06-01

    Full Text Available Abstract Background Fragmented QRS (fQRS complexes are novel electrocardiographic signals, which reflect myocardial conduction delays in patients with coronary artery disease (CAD. The importance of fQRS complexes in identifying culprit vessels was evaluated in this retrospective study. Methods A 12-lead surface electrocardiogram was obtained in 183 patients who had non-ST-elevation myocardial infarction (NSTEMI and subsequently underwent coronary angiography (CAG. On the basis of the frequency of fQRS complexes, indices such as sensitivity, specificity, positive and negative predictive values, and likelihood ratio were evaluated to determine the ability of fQRS complexes to identify the culprit vessels. Results Among the patients studied, elderly patients (age ≥ 65 years and those with diabetes had a significantly higher frequency of fQRS complexes (p = 0.005, p = 0.003, respectively. The fQRS complexes recorded in the 4 precordial leads had the highest specificity (81.8% for indentifying the culprit vessel (left anterior descending artery. However, the specificity of fQRS complexes to identify lesions in the left circumflex and right coronary arteries was lower for the inferior and lateral leads than for the limb leads (65.5% versus 71.7%; however, the limb leads had higher sensitivity (92.3% versus 89.4%. And the total sensitivity and specificity of fQRS (77.1% and 71.5% were higher than those values for ischemic T-waves. Conclusions The frequency of fQRS complexes was higher in elderly and diabetic patients with NSTEMI. The frequency of fQRS complexes recorded in each of the ECG leads can be used to identify culprit vessels in patients with NSTEMI.

  18. The roles of the Q (q) wave in lead I and QRS frontal axis for diagnosing loss of left ventricular capture during cardiac resynchronization therapy.

    Science.gov (United States)

    Cao, Yuan-Yuan; Su, Yan-Gang; Bai, Jin; Wang, Wei; Wang, Jing-Feng; Qin, Sheng-Mei; Ge, Jun-Bo

    2015-01-01

    Loss of left ventricular (LV) capture may lead to deterioration of heart failure in patients with cardiac resynchronization therapy (CRT). Recognition of loss of LV capture in time is important in clinical practice. A total of 422 electrocardiograms were acquired and analyzed from 53 CRT patients at 8 different pacing settings (LV only, right ventricle [RV] only, biventricular [BV] pacing with LV preactivation of 60, 40, 20, and 0 milliseconds and RV preactivation of 20 and 40 milliseconds). A modified Ammann algorithm by adding a third step-presence of Q (q, or QS) wave-to the original 2-step Ammann algorithm and a QRS axis shift method were devised to identify the loss of LV capture. The accuracy of modified Ammann algorithm was significantly higher than that of Ammann algorithm (78.9% vs. 69.1%, P capture. The LV preactivation, or simultaneous BV activation and LV lead positioned in nonposterior or noninferior wall can increase the diagnostic power of the modified Ammann algorithm and QRS axis shift method. © 2014 Wiley Periodicals, Inc.

  19. Left ventricular outflow tract arrhythmias with divergent QRS morphology: mapping of different exits and ablation strategy.

    Science.gov (United States)

    Reithmann, Christopher; Fiek, Michael

    2018-01-01

    Ventricular arrhythmias (VAs) from the left ventricular outflow tract (LVOT) can have multiple exits exhibiting divergent ECG features. In a series of 131 patients with VAs with LVOT origin, 10 patients presented with divergent QRS morphologies. Multisite endo- and epicardial mapping of different exit sites was performed. The earliest ventricular activity of 23 LVOT VAs in 10 patients was detected in the endocardium of the LV in 7 patients, the aortic sinuses of Valsalva (SoV) in 3 patients, the distal coronary sinus in 6 patients, the anterior interventricular vein in 3 patients, and the posterior right ventricular outflow tract (RVOT) in 4 patients. Simultaneous elimination of two divergent QRS morphologies of LVOT VAs by ablation from a single site was achieved in 5 patients (aorto-mitral continuity in 3 patients, SoV and RVOT in each 1 patient) using a mean maximum ablation energy of 46 ± 5 W. Sequential ablation from two or three different sites, including trans-pericardial and distal coronary sinus ablation in each 2 patients, led to elimination of the divergent VA QRS morphologies in the other 5 patients. During the follow-up of 28 ± 29 months, 4 of the 10 patients had recurrence of at least one LVOT VA. A 43-year-old patient with muscular dystrophy Curschmann-Steinert had recurrence of sustained LVOT VTs and died of sudden cardiac death. Multisite mapping of different exit sites of LVOT VAs can guide ablation of intramural foci but the recurrence rate after initially successful ablation was high.

  20. Effect of oxygen treatment on heart rate after abdominal surgery

    DEFF Research Database (Denmark)

    Rosenberg-Adamsen, S; Lie, C; Bernhard, A

    1999-01-01

    BACKGROUND: Cardiac complications are common during the postoperative period and may be associated with hypoxemia and tachycardia. Preliminary studies in high-risk patients after operation have shown a possible beneficial effect of oxygen therapy on arterial oxygen saturation and heart rate....... METHODS: The authors studied the effect of oxygen therapy on arterial oxygen saturation and heart rate in 100 consecutive unselected patients randomly and double blindly allocated to receive air or oxygen therapy between the first and fourth day after major abdominal surgery. RESULTS: The median arterial...... oxygen saturation rate increased significantly from 96% to 99% (P heart rate decreased significantly from 85 beats/min to 81 beats/min (P heart rate occurred...

  1. Pulmonary Right Ventricular Resynchronization in Congenital Heart Disease: Acute Improvement in Right Ventricular Mechanics and Contraction Efficiency.

    Science.gov (United States)

    Janoušek, Jan; Kovanda, Jan; Ložek, Miroslav; Tomek, Viktor; Vojtovič, Pavel; Gebauer, Roman; Kubuš, Peter; Krejčíř, Miroslav; Lumens, Joost; Delhaas, Tammo; Prinzen, Frits

    2017-09-01

    Electromechanical discoordination may contribute to long-term pulmonary right ventricular (RV) dysfunction in patients after surgery for congenital heart disease. We sought to evaluate changes in RV function after temporary RV cardiac resynchronization therapy. Twenty-five patients aged median 12.0 years after repair of tetralogy of Fallot and similar lesions were studied echocardiographically (n=23) and by cardiac catheterization (n=5) after primary repair (n=4) or after surgical RV revalvulation for significant pulmonary regurgitation (n=21). Temporary RV cardiac resynchronization therapy was applied in the presence of complete right bundle branch block by atrial-synchronized RV free wall pacing in complete fusion with spontaneous ventricular depolarization using temporary electrodes. The q-RV interval at the RV free wall pacing site (mean 77.2% of baseline QRS duration) confirmed pacing from a late activated RV area. RV cardiac resynchronization therapy carried significant decrease in QRS duration ( P right bundle branch block QRS morphology, increase in RV filling time ( P =0.002), pulmonary artery velocity time integral ( P =0.006), and RV maximum +dP/dt ( P right bundle branch block, RV cardiac resynchronization therapy carried multiple positive effects on RV mechanics, synchrony, and contraction efficiency. © 2017 American Heart Association, Inc.

  2. Blood Pressure vs. Heart Rate

    Science.gov (United States)

    ... Peripheral Artery Disease Venous Thromboembolism Aortic Aneurysm More Blood Pressure vs. Heart Rate (Pulse) Updated:Nov 13,2017 ... This content was last reviewed October 2016. High Blood Pressure • Home • Get the Facts About HBP Introduction What ...

  3. Heart rate and heart rate variability modification in chronic insomnia patients.

    Science.gov (United States)

    Farina, Benedetto; Dittoni, Serena; Colicchio, Salvatore; Testani, Elisa; Losurdo, Anna; Gnoni, Valentina; Di Blasi, Chiara; Brunetti, Riccardo; Contardi, Anna; Mazza, Salvatore; Della Marca, Giacomo

    2014-01-01

    Chronic insomnia is highly prevalent in the general population, provoking personal distress and increased risk for psychiatric and medical disorders. Autonomic hyper-arousal could be a pathogenic mechanism of chronic primary insomnia. The aim of this study was to investigate autonomic activity in patients with chronic primary insomnia by means of heart rate variability (HRV) analysis. Eighty-five consecutive patients affected by chronic primary insomnia were enrolled (38 men and 47 women; mean age: 53.2 ± 13.6). Patients were compared with a control group composed of 55 healthy participants matched for age and gender (23 men and 32 women; mean age: 54.2 ± 13.9). Patients underwent an insomnia study protocol that included subjective sleep evaluation, psychometric measures, and home-based polysomnography with evaluation of HRV in wake before sleep, in all sleep stages, and in wake after final awakening. Patients showed modifications of heart rate and HRV parameters, consistent with increased sympathetic activity, while awake before sleep and during Stage-2 non-REM sleep. No significant differences between insomniacs and controls could be detected during slow-wave sleep, REM sleep, and post-sleep wake. These results are consistent with the hypothesis that autonomic hyper-arousal is a major pathogenic mechanism in primary insomnia, and confirm that this condition is associated with an increased cardiovascular risk.

  4. Does Maturity Affect Cephalic Perfusion and T/QRS Ratio during Prolonged Umbilical Cord Occlusion in Fetal Sheep?

    Directory of Open Access Journals (Sweden)

    Guido Wassink

    2014-01-01

    Full Text Available T/QRS ratio monitoring is used to help identify fetal asphyxia. However, immature animals have greater capacity to maintain blood pressure during severe asphyxia, raising the possibility that they may show an attenuated T/QRS increase during asphyxia. Chronically instrumented fetal sheep at 0.6 of gestation (0.6 GA; n = 12, 0.7 GA (n = 12, and 0.8 GA (n = 8 underwent complete umbilical cord occlusion for 30 min, 25 min, or 15 min, respectively. Cord occlusion was associated with progressive metabolic acidosis and initial hypertension followed by severe hypotension, with a more rapid fall in mean arterial blood pressure (MAP and carotid blood flow (CaBF with advancing gestation. T/QRS ratio rose after occlusion more rapidly at 0.8 GA than in immature fetuses, to a similar final peak at all ages, followed by a progressive fall that was slower at 0.8 GA than in the immature fetuses. The increase in T/QRS ratio correlated with initial hypertension at 0.8 GA (P<0.05, R2 = 0.38, and conversely, its fall correlated closely with falling MAP in all gestational groups (P<0.01, R2 = 0.67. In conclusion, elevation of the T/QRS ratio is an index of onset of severe asphyxia in the last third of gestation, but not of fetal compromise.

  5. Impact of Ejection Fraction on the Clinical Response to Cardiac Resynchronization Therapy in Mild Heart Failure

    DEFF Research Database (Denmark)

    Linde, Cecilia; Daubert, Claude; Abraham, William T

    2013-01-01

    Current guidelines recommend cardiac resynchronization therapy (CRT) in mild heart failure (HF) patients with QRS prolongation and ejection fraction (EF) ≤30%. To assess the effect of CRT in less severe systolic dysfunction, outcomes in the REsynchronization reVErses Remodeling in Systolic left v...

  6. Exaggerated heart rate oscillations during two meditation techniques.

    Science.gov (United States)

    Peng, C K; Mietus, J E; Liu, Y; Khalsa, G; Douglas, P S; Benson, H; Goldberger, A L

    1999-07-31

    We report extremely prominent heart rate oscillations associated with slow breathing during specific traditional forms of Chinese Chi and Kundalini Yoga meditation techniques in healthy young adults. We applied both spectral analysis and a novel analytic technique based on the Hilbert transform to quantify these heart rate dynamics. The amplitude of these oscillations during meditation was significantly greater than in the pre-meditation control state and also in three non-meditation control groups: i) elite athletes during sleep, ii) healthy young adults during metronomic breathing, and iii) healthy young adults during spontaneous nocturnal breathing. This finding, along with the marked variability of the beat-to-beat heart rate dynamics during such profound meditative states, challenges the notion of meditation as only an autonomically quiescent state.

  7. Association of heart rate profile during exercise with the severity of coronary artery disease.

    Science.gov (United States)

    Cay, Serkan; Ozturk, Sezgin; Biyikoglu, Funda; Yildiz, Abdulkadir; Cimen, Tolga; Uygur, Belma; Tuna, Funda

    2009-05-01

    Coronary artery disease is the leading cause of morbidity and mortality around the world. Autonomic nervous system abnormalities are associated with coronary artery disease and its complications. Exercise stress tests are routinely used for the detection of the presence of coronary artery disease. In this study, we observed the association between heart rate profile during exercise and the severity of coronary artery disease. One hundred and sixty patients with abnormal exercise treadmill test (> or =1 mm horizontal or downsloping ST-segment depression; 119 men, 41 women; mean age = 57 +/- 9 years) were included in the study. Use of any drug affecting heart rate was not permitted. Resting heart rate before exercise, maximum heart rate during exercise, and resting heart rate after exercise (5 min later) were measured and two parameters were calculated: heart rate increment (maximum heart rate - resting heart rate before exercise) and heart rate decrement (maximum heart rate - resting heart rate after exercise). All patients underwent selective coronary angiography and subclassified into two groups according to stenotic lesion severity. Group 1 had at least 50% of stenotic lesion and group 2 had less than 50%. Patients in the first group had increased resting heart rate, decreased maximum heart rate, decreased heart rate increment, and decreased heart rate decrement compared with second group. All patients were classified into tertiles of resting heart rate, heart rate increment, and heart rate decrement level to evaluate whether these parameters were associated with severity of coronary artery stenosis in the study. The multiple-adjusted odds ratio of the risk of severe coronary atherosclerosis was 21.888 (95% confidence interval 6.983-68.606) for the highest tertile of resting heart rate level compared with the lowest tertile. In addition, the multiple-adjusted odds ratio of the risk of severe coronary atherosclerosis was 20.987 (95% confidence interval 6

  8. Discovery of novel heart rate-associated loci using the Exome Chip

    DEFF Research Database (Denmark)

    van den Berg, Marten E; Warren, Helen R; Cabrera, Claudia P

    2017-01-01

    Resting heart rate is a heritable trait, and an increase in heart rate is associated with increased mortality risk. Genome-wide association study analyses have found loci associated with resting heart rate, at the time of our study these loci explained 0.9% of the variation. This study aims to di......) and fetal muscle samples by including our novel variants.Our findings advance the knowledge of the genetic architecture of heart rate, and indicate new candidate genes for follow-up functional studies....

  9. Comparison of Selvester QRS score with magnetic resonance imaging measured infarct size in patients with ST elevation myocardial infarction

    DEFF Research Database (Denmark)

    Carlsen, Esben A; Bang, Lia E; Ahtarovski, Kiril A

    2012-01-01

    Recent studies have shown that the Selvester QRS score is significantly correlated with delayed enhancement-magnetic resonance imaging (DE-MRI) measured myocardial infarct (MI) size in reperfused ST elevation MI (STEMI). This study further tests the hypothesis that Selvester QRS score correlates...

  10. A randomised, simulated study assessing auscultation of heart rate at birth

    NARCIS (Netherlands)

    Voogdt, Kevin G. J. A.; Morrison, Allison C.; Wood, Fiona E.; van Elburg, Ruurd M.; Wyllie, Jonathan P.

    2010-01-01

    Heart rate is a primary clinical indicator directing newborn resuscitation. The time taken to assess the heart rate by auscultation in relation to accuracy during newborn resuscitation is not known. To assess both the accuracy and time taken to assess heart rate by stethoscope in simulated

  11. Real-Time 12-Lead High-Frequency QRS Electrocardiography for Enhanced Detection of Myocardial Ischemia and Coronary Artery Disease

    Science.gov (United States)

    Schlegel, Todd T.; Kulecz, Walter B.; DePalma, Jude L.; Feiveson, Alan H.; Wilson, John S.; Rahman, M. Atiar; Bungo, Michael W.

    2004-01-01

    Several studies have shown that diminution of the high-frequency (HF; 150-250 Hz) components present within the central portion of the QRS complex of an electrocardiogram (ECG) is a more sensitive indicator for the presence of myocardial ischemia than are changes in the ST segments of the conventional low-frequency ECG. However, until now, no device has been capable of displaying, in real time on a beat-to-beat basis, changes in these HF QRS ECG components in a continuously monitored patient. Although several software programs have been designed to acquire the HF components over the entire QRS interval, such programs have involved laborious off-line calculations and postprocessing, limiting their clinical utility. We describe a personal computer-based ECG software program developed recently at the National Aeronautics and Space Administration (NASA) that acquires, analyzes, and displays HF QRS components in each of the 12 conventional ECG leads in real time. The system also updates these signals and their related derived parameters in real time on a beat-to-beat basis for any chosen monitoring period and simultaneously displays the diagnostic information from the conventional (low-frequency) 12-lead ECG. The real-time NASA HF QRS ECG software is being evaluated currently in multiple clinical settings in North America. We describe its potential usefulness in the diagnosis of myocardial ischemia and coronary artery disease.

  12. Assessment of post-laparotomy pain in laboratory mice by telemetric recording of heart rate and heart rate variability

    Science.gov (United States)

    Arras, Margarete; Rettich, Andreas; Cinelli, Paolo; Kasermann, Hans P; Burki, Kurt

    2007-01-01

    Background Pain of mild to moderate grade is difficult to detect in laboratory mice because mice are prey animals that attempt to elude predators or man by hiding signs of weakness, injury or pain. In this study, we investigated the use of telemetry to identify indicators of mild-to-moderate post-laparotomy pain. Results Adult mice were subjected to laparotomy, either combined with pain treatment (carprofen or flunixin, 5 mg/kg s/c bid, for 1 day) or without pain relief. Controls received anesthesia and analgesics or vehicle only. Telemetrically measured locomotor activity was undisturbed in all animals, thus confirming that any pain experienced was of the intended mild level. No symptoms of pain were registered in any of the groups by scoring the animals' outer appearance or spontaneous and provoked behavior. In contrast, the group receiving no analgesic treatment after laparotomy demonstrated significant changes in telemetry electrocardiogram recordings: increased heart rate and decreased heart rate variability parameters pointed to sympathetic activation and pain lasting for 24 hours. In addition, core body temperature was elevated. Body weight and food intake were reduced for 3 and 2 days, respectively. Moreover, unstructured cage territory and destroyed nests appeared for 1–2 days in an increased number of animals in this group only. In controls these parameters were not affected. Conclusion In conclusion, real-time telemetric recordings of heart rate and heart rate variability were indicative of mild-to-moderate post-laparotomy pain and could define its duration in our mouse model. This level of pain cannot easily be detected by direct observation. PMID:17683523

  13. Effects of Malaria on Blood Pressure, Heart Rate, Electrocardiogram ...

    African Journals Online (AJOL)

    The effect of malaria on blood pressure, heart rate, electrocardiogram and the cardiovascular responses to postural change were studied in malaria patients. Blood pressure was measured by the sphygmomanometric-auscultatory method. Standard ECG machine was used to record the electrocardiogram. Heart rate was ...

  14. Probability of detection of clinical seizures using heart rate changes.

    Science.gov (United States)

    Osorio, Ivan; Manly, B F J

    2015-08-01

    Heart rate-based seizure detection is a viable complement or alternative to ECoG/EEG. This study investigates the role of various biological factors on the probability of clinical seizure detection using heart rate. Regression models were applied to 266 clinical seizures recorded from 72 subjects to investigate if factors such as age, gender, years with epilepsy, etiology, seizure site origin, seizure class, and data collection centers, among others, shape the probability of EKG-based seizure detection. Clinical seizure detection probability based on heart rate changes, is significantly (pprobability of detecting clinical seizures (>0.8 in the majority of subjects) using heart rate is highest for complex partial seizures, increases with a patient's years with epilepsy, is lower for females than for males and is unrelated to the side of hemisphere origin. Clinical seizure detection probability using heart rate is multi-factorially dependent and sufficiently high (>0.8) in most cases to be clinically useful. Knowledge of the role that these factors play in shaping said probability will enhance its applicability and usefulness. Heart rate is a reliable and practical signal for extra-cerebral detection of clinical seizures originating from or spreading to central autonomic network structures. Copyright © 2015 British Epilepsy Association. Published by Elsevier Ltd. All rights reserved.

  15. Electrocardiogram voltage discordance: Interpretation of low QRS voltage only in the precordial leads.

    Science.gov (United States)

    Kim, Diana H; Verdino, Ralph J

    To define clinical correlates of low voltage isolated to precordial leads on the surface electrocardiogram (ECG). Low voltage (V) on the ECG is defined as QRS Vvoltage isolated to the precordial leads with normal limb lead voltages is unclear. Twelve-lead ECGs with QRS V>5mm in one or more limb leads and voltage was found in 256 of 150,000 ECGs (~0.2%). 50.4% of patients had discordant ECGs that correlated with classic etiologies, with a higher incidence of LV dilation in those with classic etiologies than those without. Low precordial voltage is associated with classic etiologies and LV dilation. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Bluetooth Heart Rate Monitors For Spaceflight

    Science.gov (United States)

    Buxton, R. E.; West, M. R.; Kalogera, K. L.; Hanson, A. M.

    2016-01-01

    Heart rate monitoring is required for crewmembers during exercise aboard the International Space Station (ISS) and will be for future exploration missions. The cardiovascular system must be sufficiently stressed throughout a mission to maintain the ability to perform nominal and contingency/emergency tasks. High quality heart rate data are required to accurately determine the intensity of exercise performed by the crewmembers and show maintenance of VO2max. The quality of the data collected on ISS is subject to multiple limitations and is insufficient to meet current requirements. PURPOSE: To evaluate the performance of commercially available Bluetooth heart rate monitors (BT_HRM) and their ability to provide high quality heart rate data to monitor crew health aboard the ISS and during future exploration missions. METHODS: Nineteen subjects completed 30 data collection sessions of various intensities on the treadmill and/or cycle. Subjects wore several BT_HRM technologies for each testing session. One electrode-based chest strap (CS) was worn, while one or more optical sensors (OS) were worn. Subjects were instrumented with a 12-lead ECG to compare the heart rate data from the Bluetooth sensors. Each BT_HRM data set was time matched to the ECG data and a +/-5bpm threshold was applied to the difference between the 2 data sets. Percent error was calculated based on the number of data points outside the threshold and the total number of data points. RESULTS: The electrode-based chest straps performed better than the optical sensors. The best performing CS was CS1 (1.6% error), followed by CS4 (3.3% error), CS3 (6.4% error), and CS2 (9.2% error). The OS resulted in 10.4% error for OS1 and 14.9% error for OS2. CONCLUSIONS: The highest quality data came from CS1, but unfortunately it has been discontinued by the manufacturer. The optical sensors have not been ruled out for use, but more investigation is needed to determine how to obtain the best quality data. CS2 will be

  17. Ventricular Tachycardia or not? An Unexpected Reason of Wide QRS Complex Tachycardia in a Young Healthy Man: Sodium Bicarbonate.

    Science.gov (United States)

    Eyuboglu, Mehmet

    2016-10-01

    Ventricular tachycardia (VT) is life-threatening subgroup of wide QRS complex tachycardia (WCT). VT is usually associated with structural heart diseases, but it can occur in the absence of any cardiovascular diseases. Adverse cardiac effect of sodium bicarbonate in healthy subjects is not well described. A 30-year-old healthy man with excessive intake of sodium bicarbonate-related VT is presented. He was using sodium bicarbonate during last 2 months to lose weight. He has no risk factors and any cardiovascular or systemic diseases. After intravenous administration of amiodarone, tachycardia ended and his rhythm converted to sinus rhythm with normal electrocardiogram. Patient is asymptomatic, and no VT was observed without any medications at 1 year of follow-up.

  18. Intrapartum fetal heart rate profiles with and without fetal asphyxia.

    Science.gov (United States)

    Low, J A; Pancham, S R; Worthington, D N

    1977-04-01

    Fetal heart rate profiles for periods up to 12 hours prior to delivery have been reviewed in 515 patients with a fetus at risk. Mechanisms other than fetal asphyxia will cause fetal heart rate decelerations, and fetal asphyxia may in some instances develop in the absence of total or late decelerations. However, an increasing incidence of total decelerations and late decelerations and particularly a marked pattern of total decelerations and late decelerations are of value in the prediction of fetal asphyxia. Fetal heart rate deceleration patterns can predict the probability of fetal asphyxia at the time of initial intervention, while a progression of fetal heart rate deceleration patterns in the individual fetus can be of assistance in the subsequent scheduling of serial acid-base assessments during labor.

  19. Effects of heart rate on myocardial thallium-201 uptake and clearance

    International Nuclear Information System (INIS)

    Nordrehaug, J.E.; Danielsen, R.; Vik-Mo, H.

    1989-01-01

    The effects of heart rate on the myocardial uptake and clearance of 201 Tl were studied prospectively in seven healthy men, mean age 43 +/- 7 (s.d.) yr. Initial and delayed (3 hr) thallium images were obtained in three views after three bicycle exercise tests: to maximal, 80% and 60% of predicted maximal heart rate. The mean of three views initial myocardial 201 Tl uptake was higher at maximal than at both 80% and 60% of predicted maximal heart rate, being 81% (p less than 0.01) and 60% (p less than 0.01) of maximal activity, respectively. The myocardial activity in the delayed images was identical. There was a linear relationship between heart rate and the initial myocardial activity, r = 0.86 (p less than 0.001). The mean (range) 201 Tl clearance was 58% (51-65), 47% (34-56), and 34% (22-49) (all differences p less than 0.01), respectively. Concordance among the three individual views in estimating clearance was best for the highest exercise level. There was a linear relationship between heart rate and clearance, r = 0.80 (p less than 0.001). Clearance was altered by only 1.67 x 10%/heart bpm (0.024 hr/heart beat). Clearance in the liver, spleen and lungs increased at submaximal exercise levels. Thus, a linear relationship between heart rate and clearance is the result of changes in the initial exercise myocardial 201 Tl activity. Submaximal exercise may reduce reproducibility of clearance estimation, and the change of myocardial clearance with heart rate seems less than previously suggested

  20. Relative influence of age, resting heart rate and sedentary life style in short-term analysis of heart rate variability

    OpenAIRE

    E.R. Migliaro; P. Contreras; S. Bech; A. Etxagibel; M. Castro; R. Ricca; K. Vicente

    2001-01-01

    In order to assess the relative influence of age, resting heart rate (HR) and sedentary life style, heart rate variability (HRV) was studied in two different groups. The young group (YG) consisted of 9 sedentary subjects aged 15 to 20 years (YG-S) and of 9 nonsedentary volunteers (YG-NS) also aged 15 to 20. The elderly sedentary group (ESG) consisted of 16 sedentary subjects aged 39 to 82 years. HRV was assessed using a short-term procedure (5 min). R-R variability was calculated in the time-...

  1. Assessment of post-laparotomy pain in laboratory mice by telemetric recording of heart rate and heart rate variability

    Directory of Open Access Journals (Sweden)

    Kasermann Hans P

    2007-08-01

    Full Text Available Abstract Background Pain of mild to moderate grade is difficult to detect in laboratory mice because mice are prey animals that attempt to elude predators or man by hiding signs of weakness, injury or pain. In this study, we investigated the use of telemetry to identify indicators of mild-to-moderate post-laparotomy pain. Results Adult mice were subjected to laparotomy, either combined with pain treatment (carprofen or flunixin, 5 mg/kg s/c bid, for 1 day or without pain relief. Controls received anesthesia and analgesics or vehicle only. Telemetrically measured locomotor activity was undisturbed in all animals, thus confirming that any pain experienced was of the intended mild level. No symptoms of pain were registered in any of the groups by scoring the animals' outer appearance or spontaneous and provoked behavior. In contrast, the group receiving no analgesic treatment after laparotomy demonstrated significant changes in telemetry electrocardiogram recordings: increased heart rate and decreased heart rate variability parameters pointed to sympathetic activation and pain lasting for 24 hours. In addition, core body temperature was elevated. Body weight and food intake were reduced for 3 and 2 days, respectively. Moreover, unstructured cage territory and destroyed nests appeared for 1–2 days in an increased number of animals in this group only. In controls these parameters were not affected. Conclusion In conclusion, real-time telemetric recordings of heart rate and heart rate variability were indicative of mild-to-moderate post-laparotomy pain and could define its duration in our mouse model. This level of pain cannot easily be detected by direct observation.

  2. Modulations of Heart Rate, ECG, and Cardio-Respiratory Coupling Observed in Polysomnography

    Directory of Open Access Journals (Sweden)

    Thomas Penzel

    2016-10-01

    Full Text Available The cardiac component of cardio-respiratory polysomnography is covered by ECG and heart rate recordings. However their evaluation is often underrepresented in summarizing reports. As complements to EEG, EOG, and EMG, these signals provide diagnostic information for autonomic nervous activity during sleep. This review presents major methodological developments in sleep research regarding heart rate, ECG and cardio-respiratory couplings in a chronological (historical sequence. It presents physiological and pathophysiological insights related to sleep medicine obtained by new technical developments. Recorded nocturnal ECG facilitates conventional heart rate variability analysis, studies of cyclical variations of heart rate, and analysis of ECG waveform. In healthy adults, the autonomous nervous system is regulated in totally different ways during wakefulness, slow-wave sleep, and REM sleep. Analysis of beat-to-beat heart-rate variations with statistical methods enables us to estimate sleep stages based on the differences in autonomic nervous system regulation. Furthermore, up to some degree, it is possible to track transitions from wakefulness to sleep by analysis of heart-rate variations. ECG and heart rate analysis allow assessment of selected sleep disorders as well. Sleep disordered breathing can be detected reliably by studying cyclical variation of heart rate combined with respiration-modulated changes in ECG morphology (amplitude of R wave and T wave.

  3. Modulations of Heart Rate, ECG, and Cardio-Respiratory Coupling Observed in Polysomnography.

    Science.gov (United States)

    Penzel, Thomas; Kantelhardt, Jan W; Bartsch, Ronny P; Riedl, Maik; Kraemer, Jan F; Wessel, Niels; Garcia, Carmen; Glos, Martin; Fietze, Ingo; Schöbel, Christoph

    2016-01-01

    The cardiac component of cardio-respiratory polysomnography is covered by ECG and heart rate recordings. However, their evaluation is often underrepresented in summarizing reports. As complements to EEG, EOG, and EMG, these signals provide diagnostic information for autonomic nervous activity during sleep. This review presents major methodological developments in sleep research regarding heart rate, ECG, and cardio-respiratory couplings in a chronological (historical) sequence. It presents physiological and pathophysiological insights related to sleep medicine obtained by new technical developments. Recorded nocturnal ECG facilitates conventional heart rate variability (HRV) analysis, studies of cyclical variations of heart rate, and analysis of ECG waveform. In healthy adults, the autonomous nervous system is regulated in totally different ways during wakefulness, slow-wave sleep, and REM sleep. Analysis of beat-to-beat heart-rate variations with statistical methods enables us to estimate sleep stages based on the differences in autonomic nervous system regulation. Furthermore, up to some degree, it is possible to track transitions from wakefulness to sleep by analysis of heart-rate variations. ECG and heart rate analysis allow assessment of selected sleep disorders as well. Sleep disordered breathing can be detected reliably by studying cyclical variation of heart rate combined with respiration-modulated changes in ECG morphology (amplitude of R wave and T wave).

  4. Using Complexity Metrics With R-R Intervals and BPM Heart Rate Measures

    DEFF Research Database (Denmark)

    Wallot, Sebastian; Fusaroli, Riccardo; Tylén, Kristian

    2013-01-01

    Lately, growing attention in the health sciences has been paid to the dynamics of heart rate as indicator of impending failures and for prognoses. Likewise, in social and cognitive sciences, heart rate is increasingly employed as a measure of arousal, emotional engagement and as a marker of inter......Lately, growing attention in the health sciences has been paid to the dynamics of heart rate as indicator of impending failures and for prognoses. Likewise, in social and cognitive sciences, heart rate is increasingly employed as a measure of arousal, emotional engagement and as a marker...... of interpersonal coordination. However, there is no consensus about which measurements and analytical tools are most appropriate in mapping the temporal dynamics of heart rate and quite different metrics are reported in the literature. As complexity metrics of heart rate variability depend critically...

  5. Heart rate variability in newborns.

    Science.gov (United States)

    Javorka, K; Lehotska, Z; Kozar, M; Uhrikova, Z; Kolarovszki, B; Javorka, M; Zibolen, M

    2017-09-22

    Heart rate (HR) and heart rate variability (HRV) in newborns is influenced by genetic determinants, gestational and postnatal age, and other variables. Premature infants have a reduced HRV. In neonatal HRV evaluated by spectral analysis, a dominant activity can be found in low frequency (LF) band (combined parasympathetic and sympathetic component). During the first postnatal days the activity in the high frequency (HF) band (parasympathetic component) rises, together with an increase in LF band and total HRV. Hypotrophy in newborn can cause less mature autonomic cardiac control with a higher contribution of sympathetic activity to HRV as demonstrated by sequence plot analysis. During quiet sleep (QS) in newborns HF oscillations increase - a phenomenon less expressed or missing in premature infants. In active sleep (AS), HRV is enhanced in contrast to reduced activity in HF band due to the rise of spectral activity in LF band. Comparison of the HR and HRV in newborns born by physiological vaginal delivery, without (VD) and with epidural anesthesia (EDA) and via sectio cesarea (SC) showed no significant differences in HR and in HRV time domain parameters. Analysis in the frequency domain revealed, that the lowest sympathetic activity in chronotropic cardiac chronotropic regulation is in the VD group. Different neonatal pathological states can be associated with a reduction of HRV and an improvement in the health conditions is followed by changes in HRV what can be use as a possible prognostic marker. Examination of heart rate variability in neonatology can provide information on the maturity of the cardiac chronotropic regulation in early postnatal life, on postnatal adaptation and in pathological conditions about the potential dysregulation of cardiac function in newborns, especially in preterm infants.

  6. Quantification of fetal heart rate regularity using symbolic dynamics

    Science.gov (United States)

    van Leeuwen, P.; Cysarz, D.; Lange, S.; Geue, D.; Groenemeyer, D.

    2007-03-01

    Fetal heart rate complexity was examined on the basis of RR interval time series obtained in the second and third trimester of pregnancy. In each fetal RR interval time series, short term beat-to-beat heart rate changes were coded in 8bit binary sequences. Redundancies of the 28 different binary patterns were reduced by two different procedures. The complexity of these sequences was quantified using the approximate entropy (ApEn), resulting in discrete ApEn values which were used for classifying the sequences into 17 pattern sets. Also, the sequences were grouped into 20 pattern classes with respect to identity after rotation or inversion of the binary value. There was a specific, nonuniform distribution of the sequences in the pattern sets and this differed from the distribution found in surrogate data. In the course of gestation, the number of sequences increased in seven pattern sets, decreased in four and remained unchanged in six. Sequences that occurred less often over time, both regular and irregular, were characterized by patterns reflecting frequent beat-to-beat reversals in heart rate. They were also predominant in the surrogate data, suggesting that these patterns are associated with stochastic heart beat trains. Sequences that occurred more frequently over time were relatively rare in the surrogate data. Some of these sequences had a high degree of regularity and corresponded to prolonged heart rate accelerations or decelerations which may be associated with directed fetal activity or movement or baroreflex activity. Application of the pattern classes revealed that those sequences with a high degree of irregularity correspond to heart rate patterns resulting from complex physiological activity such as fetal breathing movements. The results suggest that the development of the autonomic nervous system and the emergence of fetal behavioral states lead to increases in not only irregular but also regular heart rate patterns. Using symbolic dynamics to

  7. Diminution of Heart Rate Variability in Bipolar Depression

    Directory of Open Access Journals (Sweden)

    Brandon Hage

    2017-12-01

    Full Text Available Autonomic nervous system (ANS dysregulation in depression is associated with symptoms associated with the ANS. The beat-to-beat pattern of heart rate defined as heart rate variability (HRV provides a noninvasive portal to ANS function and has been proposed to represent a means of quantifying resting vagal tone. We quantified HRV in bipolar depressed (BDD patients as a measure of ANS dysregulation seeking to establish HRV as a potential diagnostic and prognostic biomarker for treatment outcome. Forty-seven BDD patients were enrolled. They were randomized to receive either escitalopram–celecoxib or escitalopram-placebo over 8 weeks in a double-blind study design. Thirty-five patients completed the HRV studies. Thirty-six healthy subjects served as controls. HRV was assessed at pretreatment and end of study and compared with that of controls. HRV was quantified and corrected for artifacts using an algorithm that incorporates time and frequency domains to address non-stationarity of the beat-to-beat heart rate pattern. Baseline high frequency-HRV (i.e., respiratory sinus arrhythmia was lower in BDD patients than controls, although the difference did not reach significance. Baseline low-frequency HRV was significantly lower in BDD patients (ln4.20 than controls (ln = 5.50 (p < 0.01. Baseline heart period was significantly shorter (i.e., faster heart rate in BDD patients than controls. No significant change in HRV parameters were detected over the course of the study with either treatment. These findings suggest that components of HRV may be diminished in BDD patients.

  8. Modeling baroreflex regulation of heart rate during orthostatic stress

    DEFF Research Database (Denmark)

    Olufsen, Mette; Tran, Hien T.; Ottesen, Johnny T.

    2006-01-01

    . The model uses blood pressure measured in the finger as an input to model heart rate dynamics in response to changes in baroreceptor nerve firing rate, sympathetic and parasympathetic responses, vestibulo-sympathetic reflex, and concentrations of norepinephrine and acetylcholine. We formulate an inverse...... in healthy and hypertensive elderly people the hysteresis loop shifts to higher blood pressure values and its area is diminished. Finally, for hypertensive elderly people the hysteresis loop is generally not closed indicating that during postural change from sitting to standing, the blood pressure resettles......During orthostatic stress, arterial and cardiopulmonary baroreflexes play a key role in maintaining arterial pressure by regulating heart rate. This study, presents a mathematical model that can predict the dynamics of heart rate regulation in response to postural change from sitting to standing...

  9. Behavioral correlates of heart rates of free-living Greater White-fronted Geese

    Science.gov (United States)

    Ely, Craig R.; Ward, D.H.; Bollinger, K.S.

    1999-01-01

    We simultaneously monitored the heart rate and behavior of nine free-living Greater White-fronted Geese (Anser albifrons) on their wintering grounds in northern California. Heart rates of wild geese were monitored via abdominally-implanted radio transmitters with electrodes that received electrical impulses of the heart and emitted a radio signal with each ventricular contraction. Post-operative birds appeared to behave normally, readily rejoining flocks and flying up to 15 km daily from night-time roost sites to feed in surrounding agricultural fields. Heart rates varied significantly among individuals and among behaviors, and ranged from less than 100 beats per minute (BPM) during resting, to over 400 BPM during flight. Heart rates varied from 80 to 140 BPM during non-strenuous activities such as walking, feeding, and maintenance activities, to about 180 BPM when birds became alert, and over 400 BPM when birds were startled, even if they did not take flight. Postflight heart rate recovery time averaged postures, as heart rates were context-dependent, and were highest in initial encounters among individuals. Instantaneous measures of physiological parameters, such as heart rate, are often better indicators of the degree of response to external stimuli than visual observations and can be used to improve estimates of energy expenditure based solely on activity data.

  10. Ciprofloxacin, an antibiotic with cardiac actions on isolated rat hearts

    Directory of Open Access Journals (Sweden)

    Loipa Galán-Martínez

    2018-04-01

    Full Text Available Context: Ciprofloxacin is the most commonly used fluoroquinolone and is prescribed as the antibiotic of choice in the treatment of several microbial infections. Some clinical reports have suggested that ciprofloxacin may induce QT-interval prolongation and Torsades de Pointes arrhythmias. This drug is a weak inhibitor of a rapid component of the cardiac delayed rectifier potassium current IKr, but there are few electrophysiological data available to assess whether ciprofloxacin has the potency to provoke QT prolongation and subsequent Torsades de Pointes arrhythmias. Aims: To evaluate the effect of ciprofloxacin on the contractile and electrical activity of isolated rat hearts. Methods: The Langendorff technique was performed in rat hearts, and the effects of ciprofloxacin (0.001 – 100 μM were measured on the cardiac force of contraction and on the RR, QRS and QTc intervals. The arrhythmogenic potential and the ventricular fibrillation threshold were evaluated with ciprofloxacin. Results: Ciprofloxacin decreased the force of contraction of all hearts studied, in a concentration-dependent manner. The estimated IC50 for the inotropic negative effect was 0.15 ± 0.04 μM. Ciprofloxacin significantly prolonged the QRS complex, QTc and RR interval. Significant arrhythmic effects with ciprofloxacin were shown and the ventricular fibrillation threshold was decreased. Conclusions: These results suggest that ciprofloxacin exerted effects on cardiac Na+, K+ and Ca2+ channels. The actions of ciprofloxacin require further studies at the cellular level. These conclusions may account for clinical data that have been reported previously.

  11. Relationship between heart rate and preference for tempo of music.

    Science.gov (United States)

    Iwanaga, M

    1995-10-01

    People prefer music with tempi ranging from 70 to 100 cycles per minute similar to that of adults' heart rate within normal daily situations. Previous studies of the relation between preferred tempi and heart rates using a pure tone also have indicated that subjects tended to prefer tempi similar to their heart rates. The present study examined this relationship using a musical piece (the theme of "It's a small world") as a stimulus. 14 undergraduate women were subjects who searched for their favorite tempi by controlling the musical tempo by themselves. The most preferred tempo was close to their cycle of heart beats, however, tempi that were one and a half and twice as fast as the heart rate were less preferred in the present study than in a previous study using a tone. Subjects preferred faster tempi in the descending series of stimuli than in the ascending one, and hence were influenced by the initial value of the tempo in the trial sequence. The effects due to the differences of the meaning of the stimuli are considered.

  12. Atrial fibrillation with wide QRS tachycardia and undiagnosed Wolff-Parkinson-White syndrome: diagnostic and therapeutic dilemmas in a pediatric patient.

    Science.gov (United States)

    Panduranga, Prashanth; Al-Farqani, Abdullah; Al-Rawahi, Najib

    2012-11-01

    A 10-year-old girl presented to the emergency department of a regional hospital with 1 episode of generalized tonic-clonic seizures. Postictal monitoring followed by a 12-lead electrocardiogram showed fast atrial fibrillation with intermittent wide QRS regular tachycardia. Immediately following this, her rhythm changed to wide QRS irregular tachycardia without hemodynamic compromise. She was suspected to have ventricular tachycardia and was treated with intravenous amiodarone with cardioversion to sinus rhythm. Subsequent electrocardiogram in sinus rhythm showed typical features of manifest Wolff-Parkinson-White (WPW) accessory pathway. This case illustrates the diagnostic and therapeutic dilemmas in patients with atrial fibrillation, wide QRS tachycardia, and undiagnosed WPW syndrome with antidromic conduction of atrial arrhythmias through the accessory pathway. Furthermore, this case demonstrates that undiagnosed wide QRS tachycardias need to be treated with drugs acting on the accessory pathway, thus keeping in mind underlying WPW syndrome as a possibility to avoid potentially catastrophic events.

  13. QRS Score at Presentation Electrocardiogram Is Correlated With Infarct Size and Mortality in ST-Segment Elevation Myocardial Infarction Patients Undergoing Primary Percutaneous Coronary Intervention.

    Science.gov (United States)

    Shiomi, Hiroki; Kosuge, Masami; Morimoto, Takeshi; Watanabe, Hiroki; Taniguchi, Tomohiko; Nakatsuma, Kenji; Toyota, Toshiaki; Yamamoto, Erika; Shizuta, Satoshi; Tada, Tomohisa; Furukawa, Yutaka; Nakagawa, Yoshihisa; Ando, Kenji; Kadota, Kazushige; Kimura, Kazuo; Kimura, Takeshi

    2017-07-25

    In ST-segment elevation myocardial infarction (STEMI), QRS score at presentation ECG may reflect the progression of infarction and facilitate prediction of the degree of myocardial salvage achieved by reperfusion therapy.Methods and Results:Admission electrocardiogram (ECG) was studied in 2,607 patients with STEMI undergoing primary percutaneous coronary intervention (PCI) within 24 h of symptom onset. Patients were classified into 3 groups according to QRS score: low (0-3, n=1,227), intermediate (4-7, n=810), and high (≥8, n=570). An increase of infarct size estimated by median peak creatine phosphokinase was observed as QRS score increased (low score, 1,836 IU/L; inter-quartile range (IQR), 979-3,190 IU/L; intermediate score, 2,488 IU/L; IQR, 1,126-4,640 IU/L; high score, 3,454 IU/L; IQR, 1,759-5,639 IU/L; P<0.001). Higher QRS score was associated with higher long-term mortality (low, intermediate, and high score, 15.6%, 19.7%, and 23.7% at 5 years, respectively; log-rank P<0.001). The positive relationship of QRS score with mortality was consistently seen when stratified by infarct location. The association of high QRS score with increased mortality was most remarkably seen in patients with early (≤2 h) presentation (low, intermediate, and high score: 16.7%, 16.6%, and 28.1% at 5 years, respectively; log-rank P<0.001). Higher QRS score at presentation ECG was associated with larger infarct size, and higher long-term mortality in patients with STEMI undergoing primary PCI. QRS score appears to be important in the early risk stratification for STEMI.

  14. Heart-Rate Recovery Index Is Impaired in Behçet's Disease

    Science.gov (United States)

    Kaya, Ergun Baris; Yorgun, Hikmet; Akdogan, Ali; Ates, Ahmet Hakan; Canpolat, Ugur; Sunman, Hamza; Aytemir, Kudret; Tokgozoglu, Lale; Kabakci, Giray; Calguneri, Meral; Ozkutlu, Hilmi; Oto, Ali

    2009-01-01

    Behçet's disease, a multisystemic inflammatory disorder, has been associated with a number of cardiovascular dysfunctions, including ventricular arrhythmias and sudden cardiac death. Heart-rate recovery after exercise can provide both an estimate of impaired parasympathetic tone and a prognosis in regard to all-cause and cardiovascular death. The aim of our study was to evaluate heart-rate recovery in Behçet's disease From January through July 2008, we examined at our outpatient clinic and prospectively enrolled 30 consecutive patients with Behçet's disease and 50 healthy control participants who were matched for age and sex. Basal electrocardiography, echocardiography, and treadmill exercise testing were performed in all patients and control participants. The heart-rate recovery index was calculated in the usual manner, by subtracting the 1st-minute (Rec1), 2nd-minute (Rec2), and 3rd-minute (Rec3) recovery heart rates from the maximal heart rate after exercise stress testing. Patients with Behçet's disease exhibited significantly lower heart-rate recovery numbers, compared with healthy control participants: Rec1, 24.28 ± 8.2 vs 34.4 ± 7.6, P = 0.002; Rec2, 49.28 ± 11.2 vs 57.5 ± 7.0, P < 0.05; and Rec3, 56.2 ± 12.11 vs 67.4 ± 8.7, P = 0.014. To our knowledge, this is the 1st study that shows an impaired heart-rate recovery index (indicative of reduced parasympathetic activity) among patients with Behçet's disease. Given the independent prognostic value of the heart-rate recovery index, our results may explain the increased occurrence of arrhythmias and sudden cardiac death in Behçet's patients. Therefore, this index may be clinically useful in the identification of high-risk patients. PMID:19693299

  15. Do high fetal catecholamine levels affect heart rate variability and ...

    African Journals Online (AJOL)

    Objectives. To deternrine the relationship between Umbilical arterial catecholamine levels and fetal heart rate variability and meconium passage. Study design. A prospective descriptive study was perfonned. Umbilical artery catecholamine levels were measured in 55 newborns and correlated with fetal heart rate before ...

  16. Fetal Heart Rate Monitoring during Labor

    Science.gov (United States)

    ... What are the types of monitoring? • How is auscultation performed? • How is electronic fetal monitoring performed? • How ... methods of fetal heart rate monitoring in labor. Auscultation is a method of periodically listening to the ...

  17. [The influence of physical exercise on heart rate variability].

    Science.gov (United States)

    Gajek, Jacek; Zyśko, Dorota; Negrusz-Kawecka, Marta; Halawa, Bogumił

    2003-03-01

    Heart rate variability is controlled by the influence of autonomic nervous system, whereas one part of the system modulates the activity of the other. There is evidence of increased sympathetic activity in patients (pts) with essential hypertension. The aim of the study was to assess the persisting influence of increased sympathetic activity 30 min after moderate physical exercise on heart rate variability in patients with arterial hypertension. The study was performed in 19 patients (10 women, mean age 52.7 +/- 9.5 years and 9 men, mean age 37.7 +/- 8.8 years) with stage I (6 pts) and stage II (13 pts) arterial hypertension. All studied pts had sinus rhythm, were free of diabetes, coronary heart disease and congestive heart failure. 24-hour Holter monitoring was performed and for 30 min before the exercise test the pts stayed in supine rest. The exercise tests were performed between 10 and 11 a.m. Immediately after the exercise all pts stayed in supine position for 30 min. The heart rate variability parameters were studied using Holter monitoring system Medilog Optima Jet and were then analysed statistically. The mean energy expenditure during the exercise was 5.8 +/- 1.1 METs and the maximal heart rate was 148.1 +/- 20.3 bpm. All studied HRV parameters were significantly different in the assessed time period compared to the baseline values (p < 0.001). Significant correlation was found between the age of the studied patients and the mean RR interval, what can be considered as a hyperkinetic (hyperadrenergic) circulatory status and shorter RR interval in younger pts. Significant negative correlation between the age and SDNN parameter (r = -0.65, p < 0.001), 30 min after the exercise mirrors the prolonged adrenergic influence in older pts. The present study shows that the influence of moderate physical exercise on heart rate variability in pts with essential hypertension is extended over 30 min period after exercise and is more pronounced in older pts. The studies

  18. Real-time, high frequency QRS electrocardiograph with reduced amplitude zone detection

    Science.gov (United States)

    Schlegel, Todd T. (Inventor); DePalma, Jude L. (Inventor); Moradi, Saeed (Inventor)

    2009-01-01

    Real time cardiac electrical data are received from a patient, manipulated to determine various useful aspects of the ECG signal, and displayed in real time in a useful form on a computer screen or monitor. The monitor displays the high frequency data from the QRS complex in units of microvolts, juxtaposed with a display of conventional ECG data in units of millivolts or microvolts. The high frequency data are analyzed for their root mean square (RMS) voltage values and the discrete RMS values and related parameters are displayed in real time. The high frequency data from the QRS complex are analyzed with imbedded algorithms to determine the presence or absence of reduced amplitude zones, referred to herein as ''RAZs''. RAZs are displayed as ''go, no-go'' signals on the computer monitor. The RMS and related values of the high frequency components are displayed as time varying signals, and the presence or absence of RAZs may be similarly displayed over time.

  19. The use of heart rate turbulence and heart rate variability in the assessment of autonomic regulation and circadian rhythm in patients with systemic lupus erythematosus without apparent heart disease.

    Science.gov (United States)

    Poliwczak, A R; Waszczykowska, E; Dziankowska-Bartkowiak, B; Koziróg, M; Dworniak, K

    2018-03-01

    Background Systemic lupus erythematosus is a progressive autoimmune disease. There are reports suggesting that patients even without overt signs of cardiovascular complications have impaired autonomic function. The aim of this study was to assess autonomic function using heart rate turbulence and heart rate variability parameters indicated in 24-hour ECG Holter monitoring. Methods Twenty-six women with systemic lupus erythematosus and 30 healthy women were included. Twenty-four hour ambulatory ECG-Holter was performed in home conditions. The basic parameters of heart rate turbulence and heart rate variability were calculated. The analyses were performed for the entire day and separately for daytime activity and night time rest. Results There were no statistically significant differences in the basic anthropometric parameters. The mean duration of disease was 11.52 ± 7.42. There was a statistically significant higher turbulence onset (To) value in patients with systemic lupus erythematosus, median To = -0.17% (minimum -1.47, maximum 3.0) versus To = -1.36% (minimum -4.53, maximum -0.41), P lupus erythematosus group than in the healthy controls, including SDANN and r-MSSD and p50NN. Concerning the morning activity and night resting periods, the results were similar as for the whole day. In the control group, higher values in morning activity were noted for parameters that characterise sympathetic activity, especially SDANN, and were significantly lower for parasympathetic parameters, including r-MSSD and p50NN, which prevailed at night. There were no statistically significant changes for systemic lupus erythematosus patients for p50NN and low and very low frequency. There was a positive correlation between disease duration and SDNN, R = 0.417; P < 0.05 and SDANN, R = 0.464; P < 0.05, a negative correlation between low/high frequency ratio and r-MSSD, R = -0.454; P < 0.05; p50NN, R = -0.435; P < 0.05 and high frequency

  20. Correlation of heart rate and radionuclide index of left ventricular contraction and relaxation

    International Nuclear Information System (INIS)

    Adachi, Haruhiko; Sugihara, Hiroki; Nakagawa, Hiroaki; Inagaki, Suetsugu; Kubota, Yasushi; Nakagawa, Masao

    1990-01-01

    Since the cardiac function indices derived from radionuclide ventriculography (RNV) are considered to depend on the heart rate, we studied the relationship between systolic or diastolic indices and heart rates in patients with normal RNV and devised a method of correcting these indices according to the heart rate. For the systolic indices, the heart rate showed significant correlation with ET (r=-0.640), PER (r=0.791) and TPE (r=-0.401) but not with EF, 1/3 EF, MNSER or 1/3 MNSER. For the diastolic indices, the heart rate correlated well with FT (r=-0.938), RFT (r=-0.736), SFT (r=-0.803), 1/3 FF (r=-0.758), PFR (r=0.759), 1/3 PFR (r=0.742) and TPF (r=-0.389) but not with AFT, 1/3 MNDFR or AFF. These results indicate that many systolic and diastolic indices derived from RNV are affected by the heart rate, So when cardiac function is evaluated with the use of radionuclide indices, those which are independent of the heart rate should be used, or they should be corrected for the heart rate. As a method of correction, we proposed a rotating method obtained by manipulation of the regression equation of heart rates and indices. This new method is certain and easier to use when the correcting equations are set into a computer program. (author)

  1. AUTONOMIC CONTROL OF HEART RATE AFTER EXERCISE IN TRAINED WRESTLERS

    Directory of Open Access Journals (Sweden)

    Carlos F Henríquez

    2013-04-01

    Full Text Available The objective of this study was to establish differences in vagal reactivation, through heart rate recovery and heart rate variability post exercise, in Brazilian jiu-jitsu wrestlers (BJJW. A total of 18 male athletes were evaluated, ten highly trained (HT and eight moderately trained (MT, who performed a maximum incremental test. At the end of the exercise, the R-R intervals were recorded during the first minute of recovery. We calculated heart rate recovery (HRR60s, and performed linear and non-linear (standard deviation of instantaneous beat-to-beat R-R interval variability – SD1 analysis of heart rate variability (HRV, using the tachogram of the first minute of recovery divided into four segments of 15 s each (0-15 s, 15-30 s, 30-45 s, 45-60 s. Between HT and MT individuals, there were statistically significant differences in HRR60s (p <0.05 and in the non linear analysis of HRV from SD130-45s (p <0.05 and SD145-60s (p <0.05. The results of this research suggest that heart rate kinetics during the first minute after exercise are related to training level and can be used as an index for autonomic cardiovascular control in BJJW.

  2. Design of heart rate monitor based on piezoelectric sensor using an Arduino

    Science.gov (United States)

    Setyowati, Veni; Muninggar, Jodelin; Shanti. N. A, Made R. S.

    2017-01-01

    Reading of result heart rate using an acoustic stethoscope needs a particular skill, quiet environment, and hearing sensitivity. This project had the purpose design of a user-friendly automatic heart rate monitor and especially in a noisy area which to eliminate problems and incorrect reading of result. The liquid crystal display shows a heart rate as a result of measurements. The design of the heart rate monitor has two main parts; the signal recorder that a piezoelectric sensor, a filter, and an amplifier as recorder. The second parts was Arduino microcontroller with reinforced. Besides, three supporting buttons provided as the manual switches, the ‘on’, the ‘start’, and ‘reset’ buttons. The values acquired from the heart rate monitor indicate that those were on the Vernier BPS-BTA value range. The measurement error factor of the heart rate monitor then compared to the Vernier BPS-BTA test device was 3.15%. Besides, the value of statistical independent-test indicates that there is no significant difference (P = 0.971) between the heart rate monitor device and the Vernier BPS-BTA. In conclusion, this device was ready to be used because it has almost the same accuracy with the standart device.

  3. A healthy heart is not a metronome: an integrative review of the heart's anatomy and heart rate variability.

    Science.gov (United States)

    Shaffer, Fred; McCraty, Rollin; Zerr, Christopher L

    2014-01-01

    Heart rate variability (HRV), the change in the time intervals between adjacent heartbeats, is an emergent property of interdependent regulatory systems that operate on different time scales to adapt to challenges and achieve optimal performance. This article briefly reviews neural regulation of the heart, and its basic anatomy, the cardiac cycle, and the sinoatrial and atrioventricular pacemakers. The cardiovascular regulation center in the medulla integrates sensory information and input from higher brain centers, and afferent cardiovascular system inputs to adjust heart rate and blood pressure via sympathetic and parasympathetic efferent pathways. This article reviews sympathetic and parasympathetic influences on the heart, and examines the interpretation of HRV and the association between reduced HRV, risk of disease and mortality, and the loss of regulatory capacity. This article also discusses the intrinsic cardiac nervous system and the heart-brain connection, through which afferent information can influence activity in the subcortical and frontocortical areas, and motor cortex. It also considers new perspectives on the putative underlying physiological mechanisms and properties of the ultra-low-frequency (ULF), very-low-frequency (VLF), low-frequency (LF), and high-frequency (HF) bands. Additionally, it reviews the most common time and frequency domain measurements as well as standardized data collection protocols. In its final section, this article integrates Porges' polyvagal theory, Thayer and colleagues' neurovisceral integration model, Lehrer et al.'s resonance frequency model, and the Institute of HeartMath's coherence model. The authors conclude that a coherent heart is not a metronome because its rhythms are characterized by both complexity and stability over longer time scales. Future research should expand understanding of how the heart and its intrinsic nervous system influence the brain.

  4. Heart rate variability in bipolar disorder

    DEFF Research Database (Denmark)

    Faurholt-Jepsen, Maria; Kessing, Lars Vedel; Munkholm, Klaus

    2017-01-01

    Background Heart rate variability (HRV) has been suggested reduced in bipolar disorder (BD) compared with healthy individuals (HC). This meta-analysis investigated: HRV differences in BD compared with HC, major depressive disorder or schizophrenia; HRV differences between affective states; HRV...

  5. Effects of hot-iron branding on heart rate, breathing rate and behaviour of anaesthetised Steller sea lions.

    Science.gov (United States)

    Walker, K A; Mellish, J E; Weary, D M

    2011-10-01

    This study assessed the heart rate, breathing rate and behavioural responses of 12 juvenile Steller sea lions during hot-iron branding under isoflurane anaesthesia. Physiological and behavioural measures were recorded in four periods: baseline (five minutes), sham branding (one minute), branding (approximately 2.7 minutes) and postbranding (five minutes). No difference in heart rate was noted from baseline to sham branding, but heart rate increased from mean (sem) 78.3 (2.4) bpm in the baseline period to 85.6 (2.5) bpm in the branding period. Heart rate remained elevated in the postbranding period, averaging 84.7 (2.5) bpm. Breathing rate averaged 2.5 (1.0) breaths/minute in the baseline and sham branding periods increased to 8.9 (1.0) breaths/minute during branding, but returned to baseline by the postbranding period. Behaviourally, half of the sea lions exhibited trembling and head and shoulder movements during branding.

  6. The clinical significance of detection to heart rate deceleration capacity and heart rate variability in patients with chronic heart failure

    Directory of Open Access Journals (Sweden)

    Jiang-rong Zhou

    2015-01-01

    Full Text Available Objective: To study the change of heart rate deceleration capacity ( DC and heart rate variability in patients with chronic heart failure (CHF and its relationship with left ventricular ejection fraction (LVEF. Methods: DC, LVEF, time and frequency domain parameters of HRV were measured in 66 patients with CHF and 34 healthy adults (control group by using 24h Holter recordings and Echocardiography. The standard deviation of normal R-R intervals( SDNN, squares of differences between adjacent NN intervals ( RMSSD,low frequency power( LFn and high frequency power( HFn and the changes of LVEF were compared between  the two groups,the relationship between DC,LVEF and HRV were studied in patients with CHF. Results: The median value of DC in the patients with CHF was significantly lower than that in control group( 3.1 ± 2.4 ms vs 7.2 ± 1.3 ms,P <0.01.Incidence of abnormal DC in the CHF group was 57.5%,which was significantly higher than that in the control group (P <0.01.The HRV index, including SDNN、RMSSD、LFn、HFn, in the CHF group was significantly lower than that in normal control group (P < 0.01. Significant positive correlation between HRV index and LVEF were confirmed (P < 0.01. Conclusions: DC and HRV index are lower in patients with CHF and have a good correlation with the left ventricular ejection fraction.

  7. Heart Rate Variability Interventions for Concussion and Rehabilitation

    Directory of Open Access Journals (Sweden)

    Robert Lake Conder

    2014-08-01

    Full Text Available The study of Heart Rate Variability (HRV has emerged as an essential component of cardiovascular health, as well as a physiological mechanism by which one can increase the interactive communication between the cardiac and the neurocognitive systems (i.e., the body and the brain. It is well-established that lack of heart rate variability implies cardiopathology, morbidity, reduced quality-of-life, and precipitous mortality. On the positive, optimal heart rate variability has been associated with good cardiovascular health, autonomic nervous system (ANS control, emotional regulation, and enhanced neurocognitive processing. In addition to health benefits, optimal HRV has been shown to improve neurocognitive performance by enhancing focus, visual acuity and readiness, and by promoting emotional regulation needed for peak performance. In concussed athletes and soldiers, concussions not only alter brain connectivity, but also alter cardiac functioning and impair cardiovascular performance upon exertion. Altered sympathetic and parasympathetic balance in the ANS has been postulated as a critical factor in refractory Post Concussive Syndrome (PCS. This article will review both the pathological aspects of reduced heart rate variability on athletic performance, as well as the cardiovascular and cerebrovascular components of concussion and PCS. Additionally, this article will review interventions with HRV biofeedback (HRV BFB training as a promising and underutilized treatment for sports and military-related concussion. Finally, this article will review research and promising case studies pertaining to use of HRV BFB for enhancement of cognition and performance, with applicability to concussion rehabilitation.

  8. The Effect of Heart Rate on the Heart Rate Variability Response to Autonomic Interventions

    Directory of Open Access Journals (Sweden)

    George E Billman

    2013-08-01

    Full Text Available Heart rate variability (HRV, the beat-to-beat variation in either heart rate (HR or heart period (R-R interval, has become a popular clinical and investigational tool to quantify cardiac autonomic regulation. However, it is not widely appreciated that, due to the inverse curvilinear relationship between HR and R-R interval, HR per se can profoundly influence HRV. It is, therefore, critical to correct HRV for the prevailing HR particularly, as HR changes in response to autonomic neural activation or inhibition. The present study evaluated the effects of HR on the HRV response to autonomic interventions that either increased (submaximal exercise, n = 25 or baroreceptor reflex activation, n = 20 or reduced (pharmacological blockade: β-adrenergic receptor, muscarinic receptor antagonists alone and in combination, n = 25, or bilateral cervical vagotomy, n = 9 autonomic neural activity in a canine model. Both total (RR interval standard deviation, RRSD and the high frequency variability (HF, 0.2 to 1.04 Hz were determined before and in response to an autonomic intervention. All interventions that reduced or abolished cardiac parasympathetic regulation provoked large reductions in HRV even after HR correction [division by mean RRsec or (mean RRsec2 for RRSD and HF, respectively] while interventions that reduced HR yielded mixed results. β-adrenergic receptor blockade reduced HRV (RRSD but not HF while both RRSD and HF increased in response to increases in arterial blood (baroreceptor reflex activation even after HR correction. These data suggest that the physiological basis for HRV is revealed after correction for prevailing HR and, further, that cardiac parasympathetic activity is responsible for a major portion of the HRV in the dog.

  9. Novel Fingertip Image-Based Heart Rate Detection Methods for a Smartphone

    Directory of Open Access Journals (Sweden)

    Rifat Zaman

    2017-02-01

    Full Text Available We hypothesize that our fingertip image-based heart rate detection methods using smartphone reliably detect the heart rhythm and rate of subjects. We propose fingertip curve line movement-based and fingertip image intensity-based detection methods, which both use the movement of successive fingertip images obtained from smartphone cameras. To investigate the performance of the proposed methods, heart rhythm and rate of the proposed methods are compared to those of the conventional method, which is based on average image pixel intensity. Using a smartphone, we collected 120 s pulsatile time series data from each recruited subject. The results show that the proposed fingertip curve line movement-based method detects heart rate with a maximum deviation of 0.0832 Hz and 0.124 Hz using time- and frequency-domain based estimation, respectively, compared to the conventional method. Moreover, another proposed fingertip image intensity-based method detects heart rate with a maximum deviation of 0.125 Hz and 0.03 Hz using time- and frequency-based estimation, respectively.

  10. An advanced algorithm for fetal heart rate estimation from non-invasive low electrode density recordings

    International Nuclear Information System (INIS)

    Dessì, Alessia; Pani, Danilo; Raffo, Luigi

    2014-01-01

    Non-invasive fetal electrocardiography is still an open research issue. The recent publication of an annotated dataset on Physionet providing four-channel non-invasive abdominal ECG traces promoted an international challenge on the topic. Starting from that dataset, an algorithm for the identification of the fetal QRS complexes from a reduced number of electrodes and without any a priori information about the electrode positioning has been developed, entering into the top ten best-performing open-source algorithms presented at the challenge. In this paper, an improved version of that algorithm is presented and evaluated exploiting the same challenge metrics. It is mainly based on the subtraction of the maternal QRS complexes in every lead, obtained by synchronized averaging of morphologically similar complexes, the filtering of the maternal P and T waves and the enhancement of the fetal QRS through independent component analysis (ICA) applied on the processed signals before a final fetal QRS detection stage. The RR time series of both the mother and the fetus are analyzed to enhance pseudoperiodicity with the aim of correcting wrong annotations. The algorithm has been designed and extensively evaluated on the open dataset A (N = 75), and finally evaluated on datasets B (N = 100) and C (N = 272) to have the mean scores over data not used during the algorithm development. Compared to the results achieved by the previous version of the algorithm, the current version would mark the 5th and 4th position in the final ranking related to the events 1 and 2, reserved to the open-source challenge entries, taking into account both official and unofficial entrants. On dataset A, the algorithm achieves 0.982 median sensitivity and 0.976 median positive predictivity. (paper)

  11. Patterns of Interspecific Variation in the Heart Rates of Embryonic Reptiles

    Science.gov (United States)

    Du, Wei-Guo; Ye, Hua; Zhao, Bo; Pizzatto, Ligia; Ji, Xiang; Shine, Richard

    2011-01-01

    New non-invasive technologies allow direct measurement of heart rates (and thus, developmental rates) of embryos. We applied these methods to a diverse array of oviparous reptiles (24 species of lizards, 18 snakes, 11 turtles, 1 crocodilian), to identify general influences on cardiac rates during embryogenesis. Heart rates increased with ambient temperature in all lineages, but (at the same temperature) were faster in lizards and turtles than in snakes and crocodilians. We analysed these data within a phylogenetic framework. Embryonic heart rates were faster in species with smaller adult sizes, smaller egg sizes, and shorter incubation periods. Phylogenetic changes in heart rates were negatively correlated with concurrent changes in adult body mass and residual incubation period among the lizards, snakes (especially within pythons) and crocodilians. The total number of embryonic heart beats between oviposition and hatching was lower in squamates than in turtles or the crocodilian. Within squamates, embryonic iguanians and gekkonids required more heartbeats to complete development than did embryos of the other squamate families that we tested. These differences plausibly reflect phylogenetic divergence in the proportion of embryogenesis completed before versus after laying. PMID:22174948

  12. Heart Rate Monitor for Portable MP3 Player.

    Science.gov (United States)

    Kim, Jaywoo; Lee, Mi-Hee; Lee, Hyoung-Ki; Choi, Kiwan; Bang, Seokwon; Kim, Sangryong

    2005-01-01

    This paper presents a photoplethysmography sensor based on a heart rate monitor for a portable MP3 player. Two major design issues are addressed: one is to acquire the sensor signal with a proper amplitude despite a wide range of variation and the other is to handle the noise contaminated signal which is caused by a motion artifact. A benchmarking test with a professional medical photoplethysmography sensor shows that our device performs very well in calculating heart rate even though our photoplethysmography sensor module was designed to be cost effective.

  13. Extraction of the fetal ECG in noninvasive recordings by signal decompositions

    International Nuclear Information System (INIS)

    Christov, I; Simova, I; Abächerli, R

    2014-01-01

    No signal processing technique has been able to reliably deliver an undistorted fetal electrocardiographic (fECG) signal from electrodes placed on the maternal abdomen because of the low signal-to-noise ratio of the fECG recorded from the maternal body surface. As a result, this led to increased rates of Caesarean deliveries of healthy infants. In an attempt to solve the problem, Physionet/Computing in Cardiology announced the 2013 Challenge: noninvasive fetal ECG. We are suggesting a method for cancellation of the maternal ECG consisting of: maternal QRS detection, heart rate dependant P-QRS-T interval selection, location of the fiducial points inside this interval for best matching by cross correlation, superimposition of the intervals, calculation of the mean signal of the P-QRS-T interval, and sequential subtraction of the mean signal from the whole fECG recording. Three signal decomposition methods were further applied in order to enhance the fetal QRSs (fQRS): principal component analysis, root-mean-square and Hotelling’s T-squared. A combined lead of all decompositions was synthesized and fQRS detection was performed on it. The current research differs from the Challenge in that it uses three signal decomposition methods to enhance the fECG. The new results for 97 recordings of test set B are: 305.657 for Event 4: Fetal heart rate (FHR) and 23.062 for Event 5: Fetal RR interval (FRR). (paper)

  14. Approximate entropy and point correlation dimension of heart rate variability in healthy subjects

    DEFF Research Database (Denmark)

    Storella, R J; Wood, H W; Mills, K M

    1999-01-01

    The contribution of nonlinear dynamics to heart rate variability in healthy humans was examined using surrogate data analysis. Several measures of heart rate variability were used and compared. Heart rates were recorded for three hours and original data sets of 8192 R-R intervals created. For each...... original data set (n = 34), three surrogate data sets were made by shuffling the order of the R-R intervals while retaining their linear correlations. The difference in heart rate variability between the original and surrogate data sets reflects the amount of nonlinear structure in the original data set....... Heart rate variability was analyzed by two different nonlinear methods, point correlation dimension and approximate entropy. Nonlinearity, though under 10 percent, could be detected with both types of heart rate variability measures. More importantly, not only were the correlations between...

  15. Depolarization changes during acute myocardial ischemia by evaluation of QRS slopes: standard lead and vectorial approach.

    Science.gov (United States)

    Romero, Daniel; Ringborn, Michael; Laguna, Pablo; Pahlm, Olle; Pueyo, Esther

    2011-01-01

    Diagnosis and risk stratification of patients with acute coronary syndromes can be improved by adding information from the depolarization phase (QRS complex) to the conventionally used ST-T segment changes. In this study, ischemia-induced changes in the main three slopes of the QRS complex, upward ( ℑ(US)) and downward ( ℑ(DS) ) slopes of the R wave as well as the upward ( ℑ(TS)) slope of the terminal S wave, were evaluated as to represent a robust measure of pathological changes within the depolarization phase. From ECG recordings both in a resting state (control recordings) and during percutaneous coronary intervention (PCI)-induced transmural ischemia, we developed a method for quantification of ℑ(US), ℑ(DS), and ℑ(TS) that incorporates dynamic ECG normalization so as to improve the sensitivity in the detection of ischemia-induced changes. The same method was also applied on leads obtained by projection of QRS loops onto their dominant directions. We show that ℑ(US), ℑ(DS), and ℑ(TS) present high stability in the resting state, thus providing a stable reference for ischemia characterization. Maximum relative factors of change ( ℜ(ℑ)) during PCI were found in leads derived from the QRS loop, reaching 10.5 and 13.7 times their normal variations in the control for ℑ(US) and ℑ(DS), respectively. For standard leads, the relative factors of change were 6.01 and 9.31. The ℑ(TS) index presented a similar behavior to that of ℑ(DS). The timing for the occurrence of significant changes in ℑ(US) and ℑ(DS) varied with lead, ranging from 30 s to 2 min after initiation of coronary occlusion. In the present ischemia model, relative ℑ(DS) changes were smaller than ST changes in most leads, however with only modest correlation between the two indices, suggesting they present different information about the ischemic process. We conclude that QRS slopes offer a robust tool for evaluating depolarization changes during myocardial ischemia.

  16. iHeartLift: a closed loop system with bio-feedback that uses music tempo variability to improve heart rate variability.

    Science.gov (United States)

    Ho, Thomas C T; Chen, Xiang

    2011-01-01

    "Musica delenit bestiam feram" translates into "Music soothes the savage beast". There is a hidden truth in this ancient quip passed down from generations. Besides soothing the heart, it also incites the heart to a healthier level of heart rate variability (HRV). In this paper, an approach to use and test music and biofeedback to increase the heart rate variability for people facing daily stress is discussed. By determining the music tempo variability (MTV) of a piece of music and current heart rate variability, iHeartLift is able to compare the 2 trends and locate a musical piece that is suited to increase the user's heart rate variability to a healthier level. With biofeedback, the 2 trends are continuously compared in real-time and the musical piece is changed in accordance with the current comparisons. A study was conducted and it was generally found that HRV can be uplifted by music regardless of language and meaning of musical lyrics but with limitations to musical genre.

  17. Heart rate variability and baroreflex sensitivity in bilateral lung transplant recipients.

    Science.gov (United States)

    Fontolliet, Timothée; Gianella, Pietro; Pichot, Vincent; Barthélémy, Jean-Claude; Gasche-Soccal, Paola; Ferretti, Guido; Lador, Frédéric

    2018-01-09

    The effects of lung afferents denervation on cardiovascular regulation can be assessed on bilateral lung transplantation patients. The high-frequency component of heart rate variability is known to be synchronous with breathing frequency. Then, if heart beat is neurally modulated by breathing frequency, we may expect disappearance of high frequency of heart rate variability in bilateral lung transplantation patients. On 11 patients and 11 matching healthy controls, we measured R-R interval (electrocardiography), blood pressure (Portapres ® ) and breathing frequency (ultrasonic device) in supine rest, during 10-min free breathing, 10-min cadenced breathing (0·25 Hz) and 5-min handgrip. We analysed heart rate variability and spontaneous variability of arterial blood pressure, by power spectral analysis, and baroreflex sensitivity, by the sequence method. Concerning heart rate variability, with respect to controls, transplant recipients had lower total power and lower low- and high-frequency power. The low-frequency/high-frequency ratio was higher. Concerning systolic, diastolic and mean arterial pressure variability, transplant recipients had lower total power (only for cadenced breathing), low frequency and low-frequency/high-frequency ratio during free and cadenced breathing. Baroreflex sensitivity was decreased. Denervated lungs induced strong heart rate variability reduction. The higher low-frequency/high-frequency ratio suggested that the total power drop was mostly due to high frequency. These results support the hypothesis that neural modulation from lung afferents contributes to the high frequency of heart rate variability. © 2018 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  18. Elevated resting heart rate, physical fitness and all-cause mortality

    DEFF Research Database (Denmark)

    Jensen, Magnus Thorsten; Suadicani, Poul; Hein, Hans Ole

    2013-01-01

    To examine whether elevated resting heart rate (RHR) is an independent risk factor for mortality or a mere marker of physical fitness (VO2Max).......To examine whether elevated resting heart rate (RHR) is an independent risk factor for mortality or a mere marker of physical fitness (VO2Max)....

  19. A ±6 ms-Accuracy, 0.68 mm2, and 2.21 μW QRS Detection ASIC

    Directory of Open Access Journals (Sweden)

    Sheng-Chieh Huang

    2012-01-01

    Full Text Available Healthcare issues arose from population aging. Meanwhile, electrocardiogram (ECG is a powerful measurement tool. The first step of ECG is to detect QRS complexes. A state-of-the-art QRS detection algorithm was modified and implemented to an application-specific integrated circuit (ASIC. By the dedicated architecture design, the novel ASIC is proposed with 0.68 mm2 core area and 2.21 μW power consumption. It is the smallest QRS detection ASIC based on 0.18 μm technology. In addition, the sensitivity is 95.65% and the positive prediction of the ASIC is 99.36% based on the MIT/BIH arrhythmia database certification.

  20. Electrophysiological effects of the aqueous extract of Averrhoa carambola L. leaves on the guinea pig heart.

    Science.gov (United States)

    Vasconcelos, C M L; Araújo, M S; Conde-Garcia, E A

    2006-07-01

    This work aims to describe some electrophysiological changes promoted by the aqueous extract (AEx) from Averrhoa carambola leaves in guinea pig heart. The experiments were carried out on isolated heart or on right atrium-ventricle preparations. In 6 hearts, the extract induced many kinds of atrioventricular blocks (1st, 2nd, and 3rd degrees); increased the QT interval from 229+/-23 to 264+/-19 ms; increased the QRS complex duration from 27+/-3.1 to 59+/-11 ms, and depressed the cardiac rate from 136+/-17 to 89+/-14b pm. Furthermore, it decreased the conduction velocity of atrial impulse (17+/-3%); reduced the intraventricular pressure (86+/-6%), and increased the conduction time between the right atrium and the His bundle (27+/-6.5%). The conduction time from the His bundle to the right ventricle was not altered. Atropine sulfate did not change either the electrocardiographic parameters or the intraventricular pressure effects promoted by the A. carambola AEx. Based on these results, the popular use of such extracts should be avoided because it can promote electrical and mechanical changes in the normal heart.

  1. Target Heart Rates

    Science.gov (United States)

    ... Check Recipe Certification Program Nutrition Requirements Heart-Check Professional Resources Contact the Heart-Check Certification Program Simple Cooking and Recipes Dining Out Choosing a Restaurant Deciphering ...

  2. Poincare indices for analyzing meditative heart rate signals

    Directory of Open Access Journals (Sweden)

    Atefeh Goshvarpour

    2015-06-01

    Full Text Available Background: Poincare plots are commonly used to study the nonlinear behavior of physiologic signals. The aim of this study is to evaluate the Poincare plot indices of human heart rate signals during meditation. Methods: For this purpose, heart rate time series of eight Chi meditators available in Physionet database were used. Poincare plots with lags of 1 and 6 were constructed, and the ratio of the minor axis to major axis (SD1/SD2 and the area of Poincare plots were calculated for each lag. Results: The results show that the SD1/SD2 ratio increased significantly during meditation compared to that before meditation, especially the index measured from Poincare plots reconstructed with a lag of 6 (p < 0.05. In addition, in both lags, the area of Poincare plots decreased significantly during meditation compared to before meditation (p < 0.05. Conclusion: The comparative dynamic measures of the Poincare plot indices during and before meditation give more insight of the heart rate signals in a specific psychophysiological state.

  3. Short- and long-term variations in non-linear dynamics of heart rate variability

    DEFF Research Database (Denmark)

    Kanters, J K; Højgaard, M V; Agner, E

    1996-01-01

    OBJECTIVES: The purpose of the study was to investigate the short- and long-term variations in the non-linear dynamics of heart rate variability, and to determine the relationships between conventional time and frequency domain methods and the newer non-linear methods of characterizing heart rate...... rate and describes mainly linear correlations. Non-linear predictability is correlated with heart rate variability measured as the standard deviation of the R-R intervals and the respiratory activity expressed as power of the high-frequency band. The dynamics of heart rate variability changes suddenly...

  4. Heart rate detection from an electronic weighing scale

    International Nuclear Information System (INIS)

    González-Landaeta, R; Casas, O; Pallàs-Areny, R

    2008-01-01

    We propose a novel technique for beat-to-beat heart rate detection based on the ballistocardiographic (BCG) force signal from a subject standing on a common electronic weighing scale. The detection relies on sensing force variations related to the blood acceleration in the aorta, works even if wearing footwear and does not require any sensors attached to the body because it uses the load cells in the scale. We have devised an approach to estimate the sensitivity and frequency response of three commercial weighing scales to assess their capability to detect the BCG force signal. Static sensitivities ranged from 490 nV V −1 N −1 to 1670 nV V −1 N −1 . The frequency response depended on the subject's mass but it was broad enough for heart rate estimation. We have designed an electronic pulse detection system based on off-the-shelf integrated circuits to sense heart-beat-related force variations of about 0.24 N. The signal-to-noise ratio of the main peaks of the force signal detected was higher than 30 dB. A Bland–Altman plot was used to compare the RR time intervals estimated from the ECG and BCG force signals for 17 volunteers. The error was ±21 ms, which makes the proposed technique suitable for short-term monitoring of the heart rate

  5. Guided imagery, anxiety, heart rate, and heart rate variability during centrifuge training.

    Science.gov (United States)

    Jing, Xiaolu; Wu, Ping; Liu, Fang; Wu, Bin; Miao, Danmin

    2011-02-01

    Centrifuge training is an important method of improving the hypergravity tolerance of pilots, cosmonauts, and Chinese astronauts. However, the concomitants of tension or anxiety often impede training. Guided imagery (GI), a mind-body relaxation technique, provides a behavioral and cognitive means whereby individuals are able to exert control over the focus of attention. This study aims to investigate the immediate effects of GI for reducing stress in centrifuge training. There were 12 healthy young men who were randomly assigned to a GI group or music group. We measured changes in heart rate during centrifuge training, in heart rate variability before and after centrifuge training, and also evaluated relaxation and anxiety in three phases: before intervention, after intervention, and following centrifuge training. The change in the pattern of anxiety was different in the two groups over the three phases. Anxiety (measured by State Anxiety Inventory) in the GI group changed from 31.7 +/- 5.9 to 26.8 +/- 2.6 and 27.8 +/- 4.1, whereas for the music group this changed from 32.2 +/- 7.6 to 31.2 +/- 8.3 and 26.8 +/- 6.8. During centrifuge training, the maximal HR for the GI group (101.2 +/- 8.8) was lower than that of the music group (123.0 +/- 19.1). In addition GI showed a decrease in low frequency (LF, 0.04-0.15 Hz) components and an increase in high frequency (HF, 0.15-0.4 Hz) components before and after centrifuge training. GI was capable of decreasing tension, anxiety, and sympathetic nervous system activity pre- or post-centrifugation.

  6. Resonance of about-weekly human heart rate rhythm with solar activity change.

    Science.gov (United States)

    Cornelissen, G; Halberg, F; Wendt, H W; Bingham, C; Sothern, R B; Haus, E; Kleitman, E; Kleitman, N; Revilla, M A; Revilla, M; Breus, T K; Pimenov, K; Grigoriev, A E; Mitish, M D; Yatsyk, G V; Syutkina, E V

    1996-12-01

    In several human adults, certain solar activity rhythms may influence an about 7-day rhythm in heart rate. When no about-weekly feature was found in the rate of change in sunspot area, a measure of solar activity, the double amplitude of a circadian heart rate rhythm, approximated by the fit of a 7-day cosine curve, was lower, as was heart rate corresponds to about-weekly features in solar activity and/or relates to a sunspot cycle.

  7. Cardiovascular effects of MnDPDP and MnCl2 in dogs with acute ischaemic heart failure

    International Nuclear Information System (INIS)

    Karlsson, J.O.G.; Pedersen, H.K.; Sager, G.; Refsum, H.; Nycomed Imaging AS, Oslo

    1997-01-01

    Purpose: To examine the cardiovascular effects of MnDPDP in a model of acute heart failure in the dog, and to compare these effects with those of MnCl 2 . Material and Methods: The study involved slow i.v. infusion of either 10, 60 and 300 μmol/kg of MnDPDP, or 1, 6 and 30 μmol/kg MnCl 2 , in increasing doses to groups of 5 dogs. Acute ischaemic heart failure was first induced by injection of polystyrene microspheres (50±10 μm) into the left coronary artery until a stable left ventricular end-diastolic pressure of approximately 20 mm Hg was achieved. The following test parameters were measured: Left ventricular end-diastolic pressure; the first derivatives of maximum rate of left ventricular contraction and relaxation; mean aortic pressure; pulmonary artery pressure; right atrial pressure; cardiac ouput; heart rate; QT-time; PQ-time; QRS-width; and plasma catecholamines. Results: Slow infusion of MnDPDP at doses up to and including 12 times the clinical dose was well tolerated in dogs without further depression of cardiovascular function during acute ischaemic heart failure. At 300 μmol/kg, i.e. 60 times the human dose, only minor haemodynamic and electrophysiological effects were seen, and these were similar to those seen after administration of 30 μmol/kg MnCl 2 . (orig./AJ)

  8. Separating the effect of respiration from the heart rate variability for cases of constant harmonic breathing

    Directory of Open Access Journals (Sweden)

    Kircher Michael

    2015-09-01

    Full Text Available Heart Rate Variability studies are a known measure for the autonomous control of the heart rate. In special situations, its interpretation can be ambiguous, since the respiration has a major influence on the heart rate variability. For this reason it has often been proposed to measure Heart Rate Variability, while the subjects are breathing at a constant respiration rate. That way the spectral influence of the respiration is known. In this work we propose to remove this constant respiratory influence from the heart rate and the Heart Rate Variability parameters to gain respiration free autonomous controlled heart rate signal. The spectral respiratory component in the heart rate signal is detected and characterized. Subsequently the respiratory effect on Heart Rate Variability is removed using spectral filtering approaches, such as the Notch filter or the Raised Cosine filter. As a result new decoupled Heart Variability parameters are gained, which could lead to new additional interpretations of the autonomous control of the heart rate.

  9. Summation and Cancellation Effects on QRS and ST-Segment Changes Induced by Simultaneous Regional Myocardial Ischemia.

    Science.gov (United States)

    Vives-Borrás, Miquel; Jorge, Esther; Amorós-Figueras, Gerard; Millán, Xavier; Arzamendi, Dabit; Cinca, Juan

    2018-01-01

    Simultaneous ischemia in two myocardial regions is a potentially lethal clinical condition often unrecognized whose corresponding electrocardiographic (ECG) patterns have not yet been characterized. Thus, this study aimed to determine the QRS complex and ST-segment changes induced by concurrent ischemia in different myocardial regions elicited by combined double occlusion of the three main coronary arteries. For this purpose, 12 swine were randomized to combination of 5-min single and double coronary artery occlusion: Group 1: left Circumflex (LCX) and right (RCA) coronary arteries ( n = 4); Group 2: left anterior descending artery (LAD) and LCX ( n = 4) and; Group 3: LAD and RCA ( n = 4). QRS duration and ST-segment displacement were measured in 15-lead ECG. As compared with single occlusion, double LCX+RCA blockade induced significant QRS widening of about 40 ms in nearly all ECG leads and magnification of the ST-segment depression in leads V1-V3 (maximal 228% in lead V3, p ST-segment elevation in precordial leads (maximal attenuation of 60% in lead V3 in LAD+LCX and 86% in lead V5 in LAD+RCA, p ST-segment elevation in leads V7-V9 was a specific sign of single LCX occlusion. In conclusion, concurrent infero-lateral ischemia was associated with a marked summation effect of the ECG changes previously elicited by each single ischemic region. By contrast, a cancellation effect on ST-segment changes with no QRS widening was observed when the left anterior descending artery was involved.

  10. Functionality of the baroreceptor nerves in heart rate regulation

    DEFF Research Database (Denmark)

    Ottesen, Johnny T.; Olufsen, Mette

    2011-01-01

    are a consequence of the memory encapsulated by the models, and the nonlinearity gives rise to sigmoidal response curves. The nonlinear afferent baroreceptor models are coupled with an effector model, and the coupled model has been used to predict baroreceptor feedback regulation of heart rate during postural...... change from sitting to standing and during head-up tilt. The efferent model couples the afferent nerve paths to the sympathetic and parasympathetic outflow, and subsequently predicts the build up of an action potential at the sinus knot of the heart. In this paper, we analyze the nonlinear afferent model...... and show that the coupled model is able to predict heart rate regulation using blood pressure data as an input...

  11. New descriptors of T-wave morphology are independent of heart rate

    DEFF Research Database (Denmark)

    Andersen, Mads Peter; Xue, Joel Q; Graff, Claus

    2008-01-01

    from daytime Holter recordings. Duration parameters (QT, ToTe, TpTe, and others), a number of basic T-wave morphology parameters (amplitude, area, and others) as well as advanced morphology descriptors (asymmetry, flatness, and others) were measured automatically. Heart rate dependence was examined...... by means of analysis of covariance. The results showed clear heart rate dependence for the QT interval (R(2) = 0.53-0.57) and a moderate degree of heart rate dependence for the basic morphology parameters (amplitude, area, and others) (R(2) = 0.17-0.42). Both the advanced T-wave descriptors (asymmetry......T-wave morphology descriptors are sensitive to drug-induced changes and may be a useful addition to the QT interval in cardiac safety trials. Intrasubject heart rate dependence of T-wave morphology was investigated in a sample of 39 healthy individuals. Ten-second electrocardiograms were obtained...

  12. Unconstrained monitoring of long-term heart and breath rates during sleep

    International Nuclear Information System (INIS)

    Chen, Wenxi; Zhu, Xin; Wei, Daming; Nemoto, Tetsu; Sugitani, Kayo; Kitamura, Kei-ichiro

    2008-01-01

    An unconstrained method for the long-term monitoring of heart and breath rates during sleep is proposed. The system includes a sensor unit and a web-based network module. The sensor unit is set beneath a pillow to pick up the pressure variations from the head induced by inhalation/exhalation movements and heart pulsation during sleep. The measured pressure signal was digitized and transferred to a remote database server via the network module. A wavelet-based algorithm was employed to detect the heart and breath rates, as well as body movement, during sleep. The overall system was utilized for a total six-month trial operation delivered to a female subject. The profiles of the heart and breath rates on a beat-by-beat and daily basis were obtained. Movements during sleep were also estimated. The results show that the daily average percentage of undetectable periods (UPs) during 881.6 sleep hours over a 180 day period was 17.2%. A total of 89.2% of sleep hours had a UP of not more than 25%. The profile of the heart rate revealed a periodic property that corresponded to the female monthly menstrual cycle. Our system shows promise as a long-term unconstrained monitor for heart and breath rates, and for other physiological parameters related to the quality of sleep and the regularity of the menstrual cycle. (note)

  13. Development and significance of a fetal electrocardiogram recorded by signal-averaged high-amplification electrocardiography.

    Science.gov (United States)

    Hayashi, Risa; Nakai, Kenji; Fukushima, Akimune; Itoh, Manabu; Sugiyama, Toru

    2009-03-01

    Although ultrasonic diagnostic imaging and fetal heart monitors have undergone great technological improvements, the development and use of fetal electrocardiograms to evaluate fetal arrhythmias and autonomic nervous activity have not been fully established. We verified the clinical significance of the novel signal-averaged vector-projected high amplification ECG (SAVP-ECG) method in fetuses from 48 gravidas at 32-41 weeks of gestation and in 34 neonates. SAVP-ECGs from fetuses and newborns were recorded using a modified XYZ-leads system. Once noise and maternal QRS waves were removed, the P, QRS, and T wave intervals were measured from the signal-averaged fetal ECGs. We also compared fetal and neonatal heart rates (HRs), coefficients of variation of heart rate variability (CV) as a parasympathetic nervous activity, and the ratio of low to high frequency (LF/HF ratio) as a sympathetic nervous activity. The rate of detection of a fetal ECG by SAVP-ECG was 72.9%, and the fetal and neonatal QRS and QTc intervals were not significantly different. The neonatal CVs and LF/HF ratios were significantly increased compared with those in the fetus. In conclusion, we have developed a fetal ECG recording method using the SAVP-ECG system, which we used to evaluate autonomic nervous system development.

  14. Aggressive behavior: an alternative model of resting heart rate and sensation seeking.

    Science.gov (United States)

    Wilson, Laura C; Scarpa, Angela

    2014-01-01

    Low resting heart rate is a well-replicated biological correlate of aggression, and sensation seeking is frequently cited as the underlying causal explanation. However, little empirical evidence supports this mediating relationship. Furthermore, the biosocial model of violence and social push theory suggest sensation seeking may moderate the relationship between heart rate and aggression. In a sample of 128 college students (82.0% White; 73.4% female), the current study tested a moderation model as an alternative relationship between resting heart rate and sensation seeking in regard to aggression. Overall, the findings partially supported an interaction effect, whereby the relationship between heart rate and aggression was moderated by sensation seeking. Specifically, the oft-noted relationship between low resting heart rate and increased aggression was found, but only for individuals with low levels of sensation seeking. If replication supports this finding, the results may better inform prevention and intervention work. © 2013 Wiley Periodicals, Inc.

  15. Heart Rate and Increased Intravascular Volume

    Czech Academy of Sciences Publication Activity Database

    Souček, M.; Kára, T.; Jurák, Pavel; Halámek, Josef; Špinarová, L.; Meluzín, J.; Toman, J.; Řiháček, I.; Šumbera, J.; Fráňa, P.

    2003-01-01

    Roč. 52, - (2003), s. 137 - 140 ISSN 0862-8408 R&D Projects: GA ČR GA102/02/1339 Institutional research plan: CEZ:AV0Z2065902 Keywords : kidneys * heart rate * atrial mechanisms Subject RIV: FA - Cardiovascular Diseases incl. Cardiotharic Surgery Impact factor: 0.939, year: 2003

  16. Are two hearts better than one?

    International Nuclear Information System (INIS)

    Barton, H.; Cowie, A.; Kalff, V.; Richardson, M.; Kelly, M.J.

    2000-01-01

    Full text: Cardiac transplantation has become routine treatment, but not all available donor hearts can be matched. Heterotopic Cardiac Transplantation (the native heart remains in-situ), a technically difficult procedure, was introduced to partly address this limitation. Post-transplantation Gated Blood Pool Scans for these patients presented two challenges - finding the best angle for imaging the transplanted left ventricle, and distinguishing the ECG signals of the native and transplanted hearts. This allowed (a) observation of serial changes in LVEF of both hearts in seven patients, and (b) resolution of the controversy of what happens to native heart function. The transplanted heart was best imaged between LAO 5 deg and RAO 45 deg. By changing ECG limb lead positions or using a wandering V lead, it was usually possible to obtain an upright QRS complex for one heart and a downward complex for the other, allowing appropriate synchronisation of the ECG trigger. The transplant heart LVEF was obtained in 20/23 studies, being always 248%. Native LVEF was obtained in all cases where it was actively sought. Preliminary findings showed that, post-transplant, native LVEF (mean±SD) deteriorated in 6/6 patients (24%±12% to 9%±4%, p 0.95). One patient's native heart was in intermittent VT making him totally dependent on the transplanted heart. In conclusion this method allowed sequential follow-up of both hearts in these patients and demonstrated that native heart function deteriorates post-heterotopic transplant. Copyright (2000) The Australian and New Zealand Society of Nuclear Medicine Inc

  17. Triboelectric Nanogenerator Enabled Body Sensor Network for Self-Powered Human Heart-Rate Monitoring.

    Science.gov (United States)

    Lin, Zhiming; Chen, Jun; Li, Xiaoshi; Zhou, Zhihao; Meng, Keyu; Wei, Wei; Yang, Jin; Wang, Zhong Lin

    2017-09-26

    Heart-rate monitoring plays a critical role in personal healthcare management. A low-cost, noninvasive, and user-friendly heart-rate monitoring system is highly desirable. Here, a self-powered wireless body sensor network (BSN) system is developed for heart-rate monitoring via integration of a downy-structure-based triboelectric nanogenerator (D-TENG), a power management circuit, a heart-rate sensor, a signal processing unit, and Bluetooth module for wireless data transmission. By converting the inertia energy of human walking into electric power, a maximum power of 2.28 mW with total conversion efficiency of 57.9% was delivered at low operation frequency, which is capable of immediately and sustainably driving the highly integrated BSN system. The acquired heart-rate signal by the sensor would be processed in the signal process circuit, sent to an external device via the Bluetooth module, and displayed on a personal cell phone in a real-time manner. Moreover, by combining a TENG-based generator and a TENG-based sensor, an all-TENG-based wireless BSN system was developed, realizing continuous and self-powered heart-rate monitoring. This work presents a potential method for personal heart-rate monitoring, featured as being self-powered, cost-effective, noninvasive, and user-friendly.

  18. Relationships between heart rate and age, bodyweight and breed in 10,849 dogs.

    Science.gov (United States)

    Hezzell, M J; Dennis, S G; Humm, K; Agee, L; Boswood, A

    2013-06-01

    To evaluate relationships between heart rate and clinical variables in healthy dogs and dogs examined at a referral hospital. Clinical data were extracted from the electronic patient records of a first opinion group (5000 healthy dogs) and a referral hospital (5849 dogs). Univariable and multi-variable general linear models were used to assess associations between heart rate and clinical characteristics. Separate multi-variable models were constructed for first opinion and referral populations. In healthy dogs, heart rate was negatively associated with bodyweight (PChihuahuas. The mean difference in heart rate between a 5 and 55 kg dog was 10.5 beats per minute. In dogs presenting to a referral hospital, heart rate was negatively associated with bodyweight (P<0.001) and the following breeds; border collie, golden retriever, Labrador retriever, springer spaniel and West Highland white terrier and positively associated with age, admitting service (emergency and critical care, emergency first opinion and cardiology) and the following breeds; Cavalier King Charles spaniel, Staffordshire bull terrier and Yorkshire terrier. Bodyweight, age, breed and disease status all influence heart rate in dogs, although these factors account for a relatively small proportion of the overall variability in heart rate. © 2013 British Small Animal Veterinary Association.

  19. Influence of different characteristics of sport on heart rate recovery in elite athletes

    Directory of Open Access Journals (Sweden)

    Anđić Radovan

    2016-01-01

    Full Text Available Introduction: One of the benefits of regular physical activity is lower resting heart rate and its faster recovery after maximal exercise test, as a result of a stronger parasympatic (vagal tone. Heart rate recovery is used as reliable parameter for prescription of the training program and also in prognostic purposes as a parameter of risk for developing cardiovascular diseases. Aim: The purpose of this study is to show significant differences in heart rate recovery after maximal exercise test and resting heart rate among different groups of elite athletes. Material and Methods: This study subjected 575 adult (23.1 ± 4.3 years, male athletes divided into four sport groups: skill, power, mixed and endurance. Every subject performed progressive, maximal cardiopulmonary exercise test on a treadmill. Heart rate recovery in first (ΔHRR1 and third (ΔHRR3 minute was calculated as a difference of maximal heart rate and heart rate in the first and the third minute after cessation of exercise, respectively. Results: Compared to skill, power and mixed group (62.9 ± 11.4; 61.5 ± 10.0; 59.9 ± 10.4 min-1 respectively, significantly lower values od resting heart rate are recorded in the endurance group (56.2 ± 10.6 min-1 (p = 0,05. Also, ΔHRR1 was significantly higher in the endurance group (33.5 ±14.3 min-1 compared to skill, power and mixed group (24.3 ± 10.9; 25.5 ± 11.2; 27.8 ± 15.6 min-1 respectively (p = 0,05. Values od ΔHRR3 were significantly higher in power, mixed and endurance groups (74.8 ± 14.3; 79.5 ± 12.7; 79.4 ± 12.6 min-1 respectively compared to skill group (67.3±16.1 min-1 (p = 0,05. Conclusion: Training endurance group of sports has the most contribution to lower resting heart rate and faster recovery of heart rate in the first minute after exercising, due to dominant parasympatic tone.

  20. Cardiorespiratory and electrocardiographic effects of methadone or morphine in the perioperative period in anesthetized dogs with continuous rate infusion of propofol and submitted to ovariohysterectomy

    Directory of Open Access Journals (Sweden)

    Priscila Pavini Cintra

    2017-03-01

    Full Text Available The aims of this study were compare the electrocardiogram (ECG and cardiopulmonary effects of methadone or morphine, both injected intravenously (IV in dogs anesthetized with continuous infusion of propofol. Sixteen healthy female mongrel dogs were used in this study for elective ovariohysterectomy. The animals were allocated in random order into two groups assigned GME (methadone 0.3 mg kg-1, IV or GMO (morphine 0.3 mg kg-1, IV. Parameters were evaluated: heart rate (HR, P-wave amplitude (Ps and PmV, interval between Ps and R waves (PR, QRS duration (QRS, R-wave amplitude (R, duration the interval between the Q and T waves (QT, systolic blood pressure (SBP, rectal temperature (RT, respiratory rate (RR, end tidal of carbon dioxide (ETCO2 and periferic oxyhemoglobin saturation (SpO2. Postoperative analgesia was assessed by mechanical nociceptive stimulus based on the scale proposed by Firth and Haldane (1999 and rescue analgesia based on the visual analogue scale. HR was lower in GME in relation to GMO. The P, PmV, PR, QRS, R and QT values remained within their normality tracks, showing no clinical importance. Apnea and ETCO2 increased in both groups. There was no difference between groups of the analgesic effects. It can be concluded that methadone and morphine promote similar cardiovascular effects after IV injection during surgery in dogs anesthetized with propofol by continuous rate infusion, however, when methadone used, assisted ventilation is required. In addition, both drugs promote postoperative analgesia until six hours.

  1. Heart rate effects of intraosseous injections using slow and fast rates of anesthetic solution deposition.

    Science.gov (United States)

    Susi, Louis; Reader, Al; Nusstein, John; Beck, Mike; Weaver, Joel; Drum, Melissa

    2008-01-01

    The authors, using a crossover design, randomly administered, in a single-blind manner, 3 primary intraosseous injections to 61 subjects using: the Wand local anesthetic system at a deposition rate of 45 seconds (fast injection); the Wand local anesthetic system at a deposition rate of 4 minutes and 45 seconds (slow injection); a conventional syringe injection at a deposition rate of 4 minutes and 45 seconds (slow injection), in 3 separate appointments spaced at least 3 weeks apart. A pulse oximeter measured heart rate (pulse). The results demonstrated the mean maximum heart rate was statistically higher with the fast intraosseous injection (average 21 to 28 beats/min increase) than either of the 2 slow intraosseous injections (average 10 to 12 beats/min increase). There was no statistically significant difference between the 2 slow injections. We concluded that an intraosseous injection of 1.4 mL of 2% lidocaine with 1 : 100,000 epinephrine with the Wand at a 45-second rate of anesthetic deposition resulted in a significantly higher heart rate when compared with a 4-minute and 45-second anesthetic solution deposition using either the Wand or traditional syringe.

  2. Cardiovascular effects of MnDPDP and MnCl{sub 2} in dogs with acute ischaemic heart failure

    Energy Technology Data Exchange (ETDEWEB)

    Karlsson, J.O.G. [Trondheim Univ. (Norway). Dept. of Physiology and Biomedical Engineering]|[Nycomed Imaging AS, Oslo (Norway). Research and Development; Mortensen, E. [Dept. of Physiology, Inst. of Medical Biology, Univ. of Tromsoe (Norway); Pedersen, H.K. [Dept. of Radiology, The National Hospital, Oslo (Norway); Sager, G. [Dept. of Pharmacology, Inst. of Medical Biology, Univ. of Tromsoe (Norway); Refsum, H. [Inst. for Experimental Medical Research, Ullevaal Hospital, Oslo Univ. (Norway)]|[Nycomed Imaging AS, Oslo (Norway). Research and Development

    1997-07-01

    Purpose: To examine the cardiovascular effects of MnDPDP in a model of acute heart failure in the dog, and to compare these effects with those of MnCl{sub 2}. Material and Methods: The study involved slow i.v. infusion of either 10, 60 and 300 {mu}mol/kg of MnDPDP, or 1, 6 and 30 {mu}mol/kg MnCl{sub 2}, in increasing doses to groups of 5 dogs. Acute ischaemic heart failure was first induced by injection of polystyrene microspheres (50{+-}10 {mu}m) into the left coronary artery until a stable left ventricular end-diastolic pressure of approximately 20 mm Hg was achieved. The following test parameters were measured: Left ventricular end-diastolic pressure; the first derivatives of maximum rate of left ventricular contraction and relaxation; mean aortic pressure; pulmonary artery pressure; right atrial pressure; cardiac ouput; heart rate; QT-time; PQ-time; QRS-width; and plasma catecholamines. Results: Slow infusion of MnDPDP at doses up to and including 12 times the clinical dose was well tolerated in dogs without further depression of cardiovascular function during acute ischaemic heart failure. At 300 {mu}mol/kg, i.e. 60 times the human dose, only minor haemodynamic and electrophysiological effects were seen, and these were similar to those seen after administration of 30 {mu}mol/kg MnCl{sub 2}. (orig./AJ).

  3. Value of Serial Heart Rate Variability Measurement for Prediction of Appropriate ICD Discharge in Patients with Heart Failure

    NARCIS (Netherlands)

    ten Sande, Judith N.; Damman, Peter; Tijssen, Jan G. P.; de Groot, Joris R.; Knops, Reinoud E.; Wilde, Arthur A. M.; van Dessel, Pascal F. H. M.

    2014-01-01

    HRV and Appropriate ICD Shock in Heart Failure Introduction Decreased heart rate variability (HRV) is associated with adverse outcomes in patients with heart failure. Our objective was to examine whether decreased HRV predicts appropriate implantable cardioverter defibrillator (ICD) shocks. Methods

  4. Smart pillow for heart-rate monitoring using a fiber optic sensor

    Science.gov (United States)

    Chen, Zhihao; Teo, Ju Teng; Ng, Soon Huat; Yim, Huiqing

    2011-03-01

    In this paper, we propose and demonstrate a new method to monitor heart rate using fiber optic microbending based sensor for in-bed non-intrusive monitoring. The sensing system consists of transmitter, receiver, sensor mat, National Instrument (NI) data acquisition (DAQ) card and a computer for signal processing. The sensor mat is embedded inside a commercial pillow. The heart rate measurement system shows an accuracy of +/-2 beats, which has been successfully demonstrated in a field trial. The key technological advantage of our system is its ability to measure heart rate with no preparation and minimal compliance by the patient.

  5. QT measurement and heart rate correction during hypoglycemia

    DEFF Research Database (Denmark)

    Christensen, Toke Folke; Randløv, Jette; Christensen, Leif Engmann

    2010-01-01

    induced by intravenous injection of two insulin types in a cross-over design. QT measurements were done using the slope-intersect (SI) and manual annotation (MA) methods. Heart rate correction was done using Bazett's (QTcB) and Fridericia's (QTcF) formulas. Results. The SI method showed significant......Introduction. Several studies show that hypoglycemia causes QT interval prolongation. The aim of this study was to investigate the effect of QT measurement methodology, heart rate correction, and insulin types during hypoglycemia. Methods. Ten adult subjects with type 1 diabetes had hypoglycemia...... prolongation at hypoglycemia for QTcB (42(6) ms; P measuring the QT interval has...

  6. Age-related disappearance of Mayer-like heart rate waves

    Science.gov (United States)

    Jarisch, W. R.; Ferguson, J. J.; Shannon, R. P.; Wei, J. Y.; Goldberger, A. L.

    1987-01-01

    The effect of age on the principal spectral components of heart rate obtained immediately after passive upright tilt was investigated in human subjects who underwent a 60-deg tilt over 9 sec. Two groups were examined, the first of which consisting of healthy male subjects aged 22-26 years, while the second was comprised of subjects aged 65-84 years on no medication; radiograms were recorded continuously beginning just prior to tilt until 3 min posttilt. The results of spectral analysis showed that elderly subjects did not exhibit the Mayer-like heart rate waves (the 0.07-0.09 Hz oscillations) that were present in the spectra of young subjects immediately after passive upright tilt. The findings are consistent with the concept of a 'dysautonomia of aging'. It is suggested that postural stress testing with spectral analysis of heart rate fluctuations may provide a useful way of assessing physiologic vs chronologic age.

  7. Estimating energy expenditure from heart rate in older adults: a case for calibration.

    Science.gov (United States)

    Schrack, Jennifer A; Zipunnikov, Vadim; Goldsmith, Jeff; Bandeen-Roche, Karen; Crainiceanu, Ciprian M; Ferrucci, Luigi

    2014-01-01

    Accurate measurement of free-living energy expenditure is vital to understanding changes in energy metabolism with aging. The efficacy of heart rate as a surrogate for energy expenditure is rooted in the assumption of a linear function between heart rate and energy expenditure, but its validity and reliability in older adults remains unclear. To assess the validity and reliability of the linear function between heart rate and energy expenditure in older adults using different levels of calibration. Heart rate and energy expenditure were assessed across five levels of exertion in 290 adults participating in the Baltimore Longitudinal Study of Aging. Correlation and random effects regression analyses assessed the linearity of the relationship between heart rate and energy expenditure and cross-validation models assessed predictive performance. Heart rate and energy expenditure were highly correlated (r=0.98) and linear regardless of age or sex. Intra-person variability was low but inter-person variability was high, with substantial heterogeneity of the random intercept (s.d. =0.372) despite similar slopes. Cross-validation models indicated individual calibration data substantially improves accuracy predictions of energy expenditure from heart rate, reducing the potential for considerable measurement bias. Although using five calibration measures provided the greatest reduction in the standard deviation of prediction errors (1.08 kcals/min), substantial improvement was also noted with two (0.75 kcals/min). These findings indicate standard regression equations may be used to make population-level inferences when estimating energy expenditure from heart rate in older adults but caution should be exercised when making inferences at the individual level without proper calibration.

  8. Resemblances of Parents and Twins in Sport Participation and Heart Rate

    NARCIS (Netherlands)

    Boomsma, D.I.; van den Bree, M.B.; Orlebeke, J.F.; Molenaar, P.C.M.

    1989-01-01

    A model to analyze resemblances of twins and parents using LISREL is outlined and applied to sports participation and heart-rate data. Sports participation and heart rate were measured in 44 monozygotic and 46 dizygotic adolescent twin pairs and in their parents. Genetic factors influence variation

  9. Gaussian Mixture Model of Heart Rate Variability

    Science.gov (United States)

    Costa, Tommaso; Boccignone, Giuseppe; Ferraro, Mario

    2012-01-01

    Heart rate variability (HRV) is an important measure of sympathetic and parasympathetic functions of the autonomic nervous system and a key indicator of cardiovascular condition. This paper proposes a novel method to investigate HRV, namely by modelling it as a linear combination of Gaussians. Results show that three Gaussians are enough to describe the stationary statistics of heart variability and to provide a straightforward interpretation of the HRV power spectrum. Comparisons have been made also with synthetic data generated from different physiologically based models showing the plausibility of the Gaussian mixture parameters. PMID:22666386

  10. Electrocardiographic Characterization of Cardiac Hypertrophy in Mice that Overexpress the ErbB2 Receptor Tyrosine Kinase

    DEFF Research Database (Denmark)

    Sysa-Shah, Polina; Sørensen, Lars L; Abraham, M Roselle

    2015-01-01

    , the ECG recordings of ErbB2(tg) mice were characterized by higher P- and R-wave amplitudes, broader QRS complexes, inverted T waves, and ST interval depression. Pearson's correlation matrix analysis of combined WT and ErbB2(tg) data revealed significant correlation between heart weight and the ECG...... parameters of QT interval (corrected for heart rate), QRS interval, ST height, R amplitude, P amplitude, and PR interval. In addition, the left ventricular posterior wall thickness as determined by echocardiography correlated with ECG-determined ST height, R amplitude, QRS interval; echocardiographic left...... ventricular mass correlated with ECG-determined ST height and PR interval. In summary, we have determined phenotypic ECG criteria to differentiate ErbB2(tg) from WT genotypes in 98.8% of mice. This inexpensive and time-efficient ECG-based phenotypic method might be applied to differentiate between genotypes...

  11. Adaptive Mean and Trend Removal of Heart Rate Variability Using Kalman Filtering

    National Research Council Canada - National Science Library

    Schloegl, A

    2001-01-01

    Analysis of heart rate van ability requires the calculation of the mean heart rate, Adaptive methods are important for online and real-time parameter estimation, In this paper we demonstrate the use...

  12. Heart rate variability in patients with systemic lupus erythematosus: a systematic review and methodological considerations.

    Science.gov (United States)

    Matusik, P S; Matusik, P T; Stein, P K

    2018-07-01

    Aim The aim of this review was to summarize current knowledge about the scientific findings and potential clinical utility of heart rate variability measures in patients with systemic lupus erythematosus. Methods PubMed, Embase and Scopus databases were searched for the terms associated with systemic lupus erythematosus and heart rate variability, including controlled vocabulary, when appropriate. Articles published in English and available in full text were considered. Finally, 11 publications were selected, according to the systematic review protocol and were analyzed. Results In general, heart rate variability, measured in the time and frequency domains, was reported to be decreased in patients with systemic lupus erythematosus compared with controls. In some systemic lupus erythematosus studies, heart rate variability was found to correlate with inflammatory markers and albumin levels. A novel heart rate variability measure, heart rate turbulence onset, was shown to be increased, while heart rate turbulence slope was decreased in systemic lupus erythematosus patients. Reports of associations of changes in heart rate variability parameters with increasing systemic lupus erythematosus activity were inconsistent, showing decreasing heart rate variability or no relationship. However, the low/high frequency ratio was, in some studies, reported to increase with increasing disease activity or to be inversely correlated with albumin levels. Conclusions Patients with systemic lupus erythematosus have abnormal heart rate variability, which reflects cardiac autonomic dysfunction and may be related to inflammatory cytokines but not necessarily to disease activity. Thus measurement of heart rate variability could be a useful clinical tool for monitoring autonomic dysfunction in systemic lupus erythematosus, and may potentially provide prognostic information.

  13. iHeartrate: a heart rate controlled in-flight music recommendation system

    NARCIS (Netherlands)

    Liu, H.; Hu, J.; Rauterberg, G.W.M.; Spink, A.J.; Grieco, O.E.; Krips, L.W.S.; Loijens, L.P.J.J.; Noldus, xx; Zimmerman, P.H.

    2010-01-01

    Travel by air, especially long distance, the enclosed environment of the aircraft cabin causes discomfort and even stress to flight passengers. In this paper, we present a new heart rate controlled music recommendation system. Heart rate is used as a stress indicator. If the user is stressed and

  14. Identification of heart rate-associated loci and their effects on cardiac conduction and rhythm disorders

    DEFF Research Database (Denmark)

    den Hoed, Marcel; Eijgelsheim, Mark; Esko, Tõnu

    2013-01-01

    of dilated cardiomyopathy, congenital heart failure and/or sudden cardiac death. In addition, genetic susceptibility to increased heart rate is associated with altered cardiac conduction and reduced risk of sick sinus syndrome, and both heart rate-increasing and heart rate-decreasing variants associate...

  15. Detection of heart beats in multimodal data: a robust beat-to-beat interval estimation approach.

    Science.gov (United States)

    Antink, Christoph Hoog; Brüser, Christoph; Leonhardt, Steffen

    2015-08-01

    The heart rate and its variability play a vital role in the continuous monitoring of patients, especially in the critical care unit. They are commonly derived automatically from the electrocardiogram as the interval between consecutive heart beat. While their identification by QRS-complexes is straightforward under ideal conditions, the exact localization can be a challenging task if the signal is severely contaminated with noise and artifacts. At the same time, other signals directly related to cardiac activity are often available. In this multi-sensor scenario, methods of multimodal sensor-fusion allow the exploitation of redundancies to increase the accuracy and robustness of beat detection.In this paper, an algorithm for the robust detection of heart beats in multimodal data is presented. Classic peak-detection is augmented by robust multi-channel, multimodal interval estimation to eliminate false detections and insert missing beats. This approach yielded a score of 90.70 and was thus ranked third place in the PhysioNet/Computing in Cardiology Challenge 2014: Robust Detection of Heart Beats in Muthmodal Data follow-up analysis.In the future, the robust beat-to-beat interval estimator may directly be used for the automated processing of multimodal patient data for applications such as diagnosis support and intelligent alarming.

  16. Gender differences of heart rate variability in healthy volunteers

    International Nuclear Information System (INIS)

    Saleem, S.; Majeed, S.M.I.; Khan, M.A.

    2012-01-01

    Objective: To identify the basic values of heart rate variability in Pakistani population and to verify our hypothesis that there are gender differences in cardiovascular autonomic modulation. Methods: The descriptive cross sectional study based on convenience probability sampling was conducted at Armed Forces Institute of Cardiology/National Institute of Heart Diseases (AFIC/NIHD) Pakistan. The duration of the study was from December 2009 to July 2010. It involved 24-hour holter monitoring of 45 healthy individuals using holter electrocardiography (ECG) recorder. Heart rate variability was analysed in time (SDNN, SDANN, SDNNi, rMSSD, pNN50) and frequency domains (power, VLF, LF, and HF). Results: The time domain indices; SDNN (male=140 +- 36 ms vs. females=122 +- 33 ms; p =0.09), SDANN (male=123 +- 34 ms vs. females=111+- 34 ms; P= 0.23), SDNNi (male=64 +-19 ms vs. females=52 +- 14 ms; P= 0.03), and pNN50 (male=14 +- 10 ms vs. females=12 +- 7 ms; P= 0.43) were decreased in female volunteers when compared with males. Comparison of frequency domain indices; Total power (male=4041 +- 3150 ms/sup 2/ vs. females=2750 +- 1439 ms/sup 2/; P= 0.07), VLF (male=291 2675 ms/sup 2/ vs. females=1843 +- 928 ms/sup 2/; P= 0.06), LF (male=788 +- 397 ms/sup 2/ vs. females=556 +- 346 ms/sup 2/; P= 0.04) and HF (male=318 +- 251 ms/sup 2/ vs. females=31 277 ms/sup 2/; P= 0.94) amongst males and females showed attenuated heart rate variability in females. Of all the observed values, SDNNi and LF were found significantly (p <0.05) decreased in women. Conclusion: In healthy population, heart rate variability is low in women than men. It reflects sympathetic dominance in women in our population. (author)

  17. Heart rate variability as determinism with jump stochastic parameters.

    Science.gov (United States)

    Zheng, Jiongxuan; Skufca, Joseph D; Bollt, Erik M

    2013-08-01

    We use measured heart rate information (RR intervals) to develop a one-dimensional nonlinear map that describes short term deterministic behavior in the data. Our study suggests that there is a stochastic parameter with persistence which causes the heart rate and rhythm system to wander about a bifurcation point. We propose a modified circle map with a jump process noise term as a model which can qualitatively capture such this behavior of low dimensional transient determinism with occasional (stochastically defined) jumps from one deterministic system to another within a one parameter family of deterministic systems.

  18. Change of Diurnal Heart Rate Patterns During Pregnancy and Lactation in Dogs (Canis familiaris

    Directory of Open Access Journals (Sweden)

    Häggström J

    2003-09-01

    Full Text Available Pregnancy and lactation involve great demands on the cardiovascular system. The purpose of this study was to investigate how the heart rate and diurnal heart rate pattern change when dogs become pregnant or lactate. Five clinically healthy female beagle dogs were mated, and delivered three to seven healthy puppies. The heart rate was investigated with 24-h ECG (Holter once during anoestrus, at 3, 5, 7 and 9 weeks of pregnancy, and at week 4 postpartum (lactation. However, at 9 weeks, the ECG could not be recorded for the fully 24 h in 4 of 5 dogs, because labour started and the dogs then appeared disturbed by the recordings. The results at this date are not included in the statistical comparison. The heart rate increased progressively during pregnancy and was still elevated at 4 weeks of lactation. During late pregnancy the difference in heart rates between daytime and nighttime became smaller, but the heart rate was significantly higher in daytime in all periods. In conclusion, the increased heart rates during pregnancy and lactation reflect increased demands on the cardiovascular system and may be important to consider in clinical practice.

  19. Electrocardiographic spatial QRS-T angle and incident cardiovascular disease in HIV-infected patients (from the Strategies for the Management of Antiretroviral Therapy [SMART] study)

    DEFF Research Database (Denmark)

    Dawood, Farah Z; Khan, Faraaz; Roediger, Mollie P

    2013-01-01

    the baseline resting 12-lead electrocardiogram of 4,453 HIV-infected patients aged 43.5 ± 9.3 years from the Strategies for Management of Antiretroviral Therapy (SMART) trial. CVD events were identified during a median follow-up of 28.7 months. Quartiles of the spatial QRS-T angle was calculated for men......Widening of the electrocardiographic (ECG) spatial QRS-T angle has been predictive of cardiovascular disease (CVD) events in the general population. However, its prognostic significance in human immunodeficiency virus (HIV)-infected patients remains unknown. The spatial QRS-T angle was derived from...... and women separately, and values in the upper quartile were considered as a widened angle (values >74° for women and >93° for men). A multivariate Cox proportional hazards analysis was used to examine the association between a widened baseline spatial QRS-T angle and incident CVD events. During 11...

  20. Conventional heart rate variability analysis of ambulatory electrocardiographic recordings fails to predict imminent ventricular fibrillation

    Science.gov (United States)

    Vybiral, T.; Glaeser, D. H.; Goldberger, A. L.; Rigney, D. R.; Hess, K. R.; Mietus, J.; Skinner, J. E.; Francis, M.; Pratt, C. M.

    1993-01-01

    OBJECTIVES. The purpose of this report was to study heart rate variability in Holter recordings of patients who experienced ventricular fibrillation during the recording. BACKGROUND. Decreased heart rate variability is recognized as a long-term predictor of overall and arrhythmic death after myocardial infarction. It was therefore postulated that heart rate variability would be lowest when measured immediately before ventricular fibrillation. METHODS. Conventional indexes of heart rate variability were calculated from Holter recordings of 24 patients with structural heart disease who had ventricular fibrillation during monitoring. The control group consisted of 19 patients with coronary artery disease, of comparable age and left ventricular ejection fraction, who had nonsustained ventricular tachycardia but no ventricular fibrillation. RESULTS. Heart rate variability did not differ between the two groups, and no consistent trends in heart rate variability were observed before ventricular fibrillation occurred. CONCLUSIONS. Although conventional heart rate variability is an independent long-term predictor of adverse outcome after myocardial infarction, its clinical utility as a short-term predictor of life-threatening arrhythmias remains to be elucidated.

  1. Behaviour, heart rate, and heart rate variability in pigs exposed to novelty

    Directory of Open Access Journals (Sweden)

    Manja Zupan

    2016-03-01

    Full Text Available ABSTRACT In the present study, we investigated behavioural responses and determined parameters of heart rate variability (HRV to elucidate a relative activation of autonomic nervous system (ANS during baseline (10 min and in response to potentially stressful situations (10 min in two pig breeds and sexes. Gilts (n = 21 and barrows (n = 9 of the Landrace × Yorkshire (LY; n = 15 and Landrace/Yorkshire × Landrace/Duroc (LYLD; n = 15 breeds were subjected to a novel object test (NOT and a novel arena test (NAT. Basal ANS state differed in pigs across breeds but not sexes. Landrace × Yorkshire pigs had a significantly lower basal heart rate (HR and low-frequency band (LF with a higher root mean square of successive interbeat intervals (RMSSD and high-frequency band (HF than LYLD pigs. In the NOT, despite having similar cardiac responses, gilts had a longer duration of contact with a novel object, higher lying and standing duration, and a lower duration of walking compared with barrows. In the NAT, we found similar behaviour across sexes but a different degree of ANS state, with barrows having a significantly higher increase in LF/HF (power of the low frequency component divided by the power of the high-frequency band compared with gilts. Landrace/Yorkshire × Landrace/Duroc pigs showed longer duration of contact with a novel object in the NOT accompanied by less lying and standing than LY pigs in both tests. No difference in ANS activation between breeds was found in the NOT. In the NAT, HR increased more from baseline to testing in LY pigs than in LYLD pigs. There is a complex and often contradictory nature of relationships between behaviour and cardiac responses to novelty in pigs of different breeds and sexes.

  2. Effects of metronome breathing on the assessment of autonomic control using heart rate variability

    NARCIS (Netherlands)

    Haaksma, J; Brouwer, J; vandenBerg, MP; Dijk, WA; Dassen, WRM; Crijns, HJGM; Mulder, Lambertus; Mulder, Gysbertus

    1996-01-01

    Analysis of Heart Rate Variability is a non-invasive quantitative tool to study the influence of the autonomic nervous system on the heart. Rapid variations in heart rate, related to breathing are primarily mediated by the vagal limb of the autonomic nervous system. The resulting variations in heart

  3. Relationship between heart rate and quiescent interval of the cardiac cycle in children using MRI

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Wei [Texas Children' s Hospital, E. B. Singleton Department of Pediatric Radiology, Houston, TX (United States); Bogale, Saivivek [Baylor University Medical Center, Department of Radiology, Dallas, TX (United States); Golriz, Farahnaz [Baylor College of Medicine, Department of Radiology, Houston, TX (United States); Krishnamurthy, Rajesh [Nationwide Children' s Hospital, Department of Diagnostic Radiology, Columbus, OH (United States)

    2017-11-15

    Imaging the heart in children comes with the challenge of constant cardiac motion. A prospective electrocardiography-triggered CT scan allows for scanning during a predetermined phase of the cardiac cycle with least motion. This technique requires knowing the optimal quiescent intervals of cardiac cycles in a pediatric population. To evaluate high-temporal-resolution cine MRI of the heart in children to determine the relationship of heart rate to the optimal quiescent interval within the cardiac cycle. We included a total of 225 consecutive patients ages 0-18 years who had high-temporal-resolution cine steady-state free-precession sequence performed as part of a magnetic resonance imaging (MRI) or magnetic resonance angiography study of the heart. We determined the location and duration of the quiescent interval in systole and diastole for heart rates ranging 40-178 beats per minute (bpm). We performed the Wilcoxon signed rank test to compare the duration of quiescent interval in systole and diastole for each heart rate group. The duration of the quiescent interval at heart rates <80 bpm and >90 bpm was significantly longer in diastole and systole, respectively (P<.0001 for all ranges, except for 90-99 bpm [P=.02]). For heart rates 80-89 bpm, diastolic interval was longer than systolic interval, but the difference was not statistically significant (P=.06). We created a chart depicting optimal quiescent intervals across a range of heart rates that could be applied for prospective electrocardiography-triggered CT imaging of the heart. The optimal quiescent interval at heart rates <80 bpm is in diastole and at heart rates ≥90 bpm is in systole. The period of quiescence at heart rates 80-89 bpm is uniformly short in systole and diastole. (orig.)

  4. Small-volume amnioinfusion: a potential stimulus of intrapartum fetal heart rate accelerations.

    Science.gov (United States)

    Wax, Joseph R; Flaherty, Nina; Pinette, Michael G; Blackstone, Jacquelyn; Cartin, Angelina

    2004-02-01

    We describe a recurrent nonreassuring fetal heart rate pattern in which small-volume amnioinfusions apparently evoked fetal heart rate accelerations suggested fetal well-being, allowing that progressive labor that culminated in the vaginal delivery of a healthy infant.

  5. Comparative analysis of a portable smartphone­based electrocardiograph (D­Heart® versus standard 6­leads electrocardiograph in the canine patient.

    Directory of Open Access Journals (Sweden)

    Alice Savarese

    2017-05-01

    Full Text Available D-Heart® is a portable, smartphone-based device, which streams tracing via Bluetooth, enabling multiple leads electrocardiograms (ECGs acquisition, currently used in human cardiology (Maurizi et al. 2017. The aim was to determine the accuracy of D­Heart® compared with the gold standard non­portable 6­lead electrocardiograph in the evaluation of cardiac rhythm in dogs. Standard 6­lead and D­Heart® ECGs were acquired in conscious dogs. Concordance between methods was assessed by weighted k Cohen index, with its relative significance, taking as end point variable standard 6­lead ECG group. Bland ­ Altman method (95% confidence level was applied for P, PR, QRS, T and QT. Since differences didn’t follow a normal distribution, a non­parametric approach was used to determine limits of agreement. P was significant when < 0.05 (Maurizi et al. 2017. Amplitude of waves was not considered because currently the software doesn’t allow voltage variation. 115 dogs of different weights and breeds admitted to the Cardiology Service of DIMEVET were enrolled. Mean age was 7,5±4 years. Most were intact males (45%, n=51. The most represented breed was mongrel (27%, n=32. Weighted Cohen's kappa test demonstrated excellent concordance in the evaluation of the heart rhythm (0.989, p<0.001, for ST segment morphology (0.991, p<0,001 and for T wave morphology (0.838, p=0.040. There was a 100% concordance in P morphology determination. P, PR, QRS, T and QT intervals comparison with Bland­Altman showed an extremely good concordance for D­Heart® measurements (95% limit of agreement ±0.9 ms for P, ±10 ms for PR, ±35 ms for QRS, ±5 ms for T wave. Less concordance resulted for QT (±80 ms. In Conclusion, D­Heart® proved effective accurate recording of ECG comparable to standard 6­lead electrocardiographs, opening new perspectives to improve diagnostic tools in veterinary cardiology. Future perspective will be the development of a telecardiology network

  6. Aerobic exercise during pregnancy and presence of fetal-maternal heart rate synchronization.

    Directory of Open Access Journals (Sweden)

    Peter Van Leeuwen

    Full Text Available It has been shown that short-term direct interaction between maternal and fetal heart rates may take place and that this interaction is affected by the rate of maternal respiration. The aim of this study was to determine the effect of maternal aerobic exercise during pregnancy on the occurrence of fetal-maternal heart rate synchronization.In 40 pregnant women at the 36th week of gestation, 21 of whom exercised regularly, we acquired 18 min. RR interval time series obtained simultaneously in the mothers and their fetuses from magnetocardiographic recordings. The time series of the two groups were examined with respect to their heart rate variability, the maternal respiratory rate and the presence of synchronization epochs as determined on the basis of synchrograms. Surrogate data were used to assess whether the occurrence of synchronization was due to chance.In the original data, we found synchronization occurred less often in pregnancies in which the mothers had exercised regularly. These subjects also displayed higher combined fetal-maternal heart rate variability and lower maternal respiratory rates. Analysis of the surrogate data showed shorter epochs of synchronization and a lack of the phase coordination found between maternal and fetal beat timing in the original data.The results suggest that fetal-maternal heart rate coupling is present but generally weak. Maternal exercise has a damping effect on its occurrence, most likely due to an increase in beat-to-beat differences, higher vagal tone and slower breathing rates.

  7. Aerobic exercise during pregnancy and presence of fetal-maternal heart rate synchronization.

    Science.gov (United States)

    Van Leeuwen, Peter; Gustafson, Kathleen M; Cysarz, Dirk; Geue, Daniel; May, Linda E; Grönemeyer, Dietrich

    2014-01-01

    It has been shown that short-term direct interaction between maternal and fetal heart rates may take place and that this interaction is affected by the rate of maternal respiration. The aim of this study was to determine the effect of maternal aerobic exercise during pregnancy on the occurrence of fetal-maternal heart rate synchronization. In 40 pregnant women at the 36th week of gestation, 21 of whom exercised regularly, we acquired 18 min. RR interval time series obtained simultaneously in the mothers and their fetuses from magnetocardiographic recordings. The time series of the two groups were examined with respect to their heart rate variability, the maternal respiratory rate and the presence of synchronization epochs as determined on the basis of synchrograms. Surrogate data were used to assess whether the occurrence of synchronization was due to chance. In the original data, we found synchronization occurred less often in pregnancies in which the mothers had exercised regularly. These subjects also displayed higher combined fetal-maternal heart rate variability and lower maternal respiratory rates. Analysis of the surrogate data showed shorter epochs of synchronization and a lack of the phase coordination found between maternal and fetal beat timing in the original data. The results suggest that fetal-maternal heart rate coupling is present but generally weak. Maternal exercise has a damping effect on its occurrence, most likely due to an increase in beat-to-beat differences, higher vagal tone and slower breathing rates.

  8. Aerobic Exercise during Pregnancy and Presence of Fetal-Maternal Heart Rate Synchronization

    Science.gov (United States)

    Van Leeuwen, Peter; Gustafson, Kathleen M.; Cysarz, Dirk; Geue, Daniel; May, Linda E.; Grönemeyer, Dietrich

    2014-01-01

    It has been shown that short-term direct interaction between maternal and fetal heart rates may take place and that this interaction is affected by the rate of maternal respiration. The aim of this study was to determine the effect of maternal aerobic exercise during pregnancy on the occurrence of fetal-maternal heart rate synchronization. Methods In 40 pregnant women at the 36th week of gestation, 21 of whom exercised regularly, we acquired 18 min. RR interval time series obtained simultaneously in the mothers and their fetuses from magnetocardiographic recordings. The time series of the two groups were examined with respect to their heart rate variability, the maternal respiratory rate and the presence of synchronization epochs as determined on the basis of synchrograms. Surrogate data were used to assess whether the occurrence of synchronization was due to chance. Results In the original data, we found synchronization occurred less often in pregnancies in which the mothers had exercised regularly. These subjects also displayed higher combined fetal-maternal heart rate variability and lower maternal respiratory rates. Analysis of the surrogate data showed shorter epochs of synchronization and a lack of the phase coordination found between maternal and fetal beat timing in the original data. Conclusion The results suggest that fetal-maternal heart rate coupling is present but generally weak. Maternal exercise has a damping effect on its occurrence, most likely due to an increase in beat-to-beat differences, higher vagal tone and slower breathing rates. PMID:25162592

  9. Heart Rate and Energy Expenditure in Division I Field Hockey Players During Competitive Play.

    Science.gov (United States)

    Sell, Katie M; Ledesma, Allison B

    2016-08-01

    Sell, KM and Ledesma, AB. Heart rate and energy expenditure in Division I field hockey players during competitive play. J Strength Cond Res 30(8): 2122-2128, 2016-The purpose of this study was to quantify energy expenditure and heart rate data for Division I female field hockey players during competitive play. Ten female Division I collegiate field hockey athletes (19.8 ± 1.6 years; 166.4 ± 6.1 cm; 58.2 ± 5.3 kg) completed the Yo-Yo intermittent endurance test to determine maximal heart rate. One week later, all subjects wore a heart rate monitor during a series of 3 matches in an off-season competition. Average heart rate (AvHR), average percentage of maximal heart rate (AvHR%), peak exercise heart rate (PExHR), and percentage of maximal heart rate (PExHR%), time spent in each of the predetermined heart rate zones, and caloric expenditure per minute of exercise (kcalM) were determined for all players. Differences between positions (backs, midfielders, and forwards) were assessed. No significant differences in AvHR, AvHR%, PExHR, PExHR%, and %TM were observed between playing positions. The AvHR% and PExHR% for each position fell into zones 4 (77-93% HRmax) and 5 (>93% HRmax), respectively, and significantly more time was spent in zone 4 compared with zones 1, 2, 3, and 5 across all players (p ≤ 0.05). The kcalM reflected very heavy intensity exercise. The results of this study will contribute toward understanding the sport-specific physiological demands of women's field hockey and has specific implications for the duration and schedule of training regimens.

  10. Bluetooth(Registered Trademark) Heart Rate Monitors for Spaceflight

    Science.gov (United States)

    Buxton, Roxanne E.; West, Michael R.; Kalogera, Kent L.; Hanson, Andrea M.

    2016-01-01

    Heart rate monitoring is required during exercise for crewmembers aboard the International Space Station (ISS) and will be for future exploration missions. The cardiovascular system must be sufficiently stressed throughout a mission to maintain the ability to perform nominal and contingency/emergency tasks. High quality heart rate data is required to accurately determine the intensity of exercise performed by the crewmembers and show maintenance of VO2max. The quality of the data collected on ISS is subject to multiple limitations and is insufficient to meet current requirements. PURPOSE: To evaluate the performance of commercially available Bluetooth® heart rate monitors (BT_HRM) and their ability to provide high quality heart rate data to monitor crew health on board ISS and during future exploration missions. METHODS: Nineteen subjects completed 30 data collection sessions of various intensities on the treadmill and/or cycle. Subjects wore several BT_HRM technologies for each testing session. One electrode-based chest strap (CS) was worn, while one or more optical sensors (OS) was worn. Subjects were instrumented with a 12-lead ECG to compare the heart rate data from the Bluetooth sensors. Each BT_RHM data set was time matched to the ECG data and a +/-5bpm threshold was applied to the difference between the two data sets. Percent error was calculated based on the number of data points outside the threshold and the total number of data points. REULTS: The electrode-based chest straps performed better than the optical sensors. The best performing CS was CS1 (1.6%error), followed by CS4 (3.3%error), CS3 (6.4%error), and CS2 (9.2%error). The OS resulted in 10.4% error for OS1 and 14.9% error for OS2. CONCLUSIONS: The highest quality data came from CS1, unfortunately it has been discontinued by the manufacturer. The optical sensors have not been ruled out for use, but more investigation is needed to determine how to get the best quality data. CS2 will be used in an

  11. Paradoxical response to an emotional task: Trait characteristics and heart-rate dynamics

    NARCIS (Netherlands)

    Balocchia, R.; Varanini, M.; Paoletti, G.; Mecacci, G.; Santarcangelo, E.L.

    2015-01-01

    The present study evaluated the heart-rate dynamics of subjects reporting decreased (responders) or paradoxically increased relaxation (nonresponders) at the end of a threatening movie. Heart-rate dynamics were characterized by indices extracted through recurrence quantification analysis (RQA) and

  12. Systematic review and meta-analysis of left ventricular endocardial pacing in advanced heart failure: Clinically efficacious but at what cost?

    Science.gov (United States)

    Graham, Adam J; Providenica, Rui; Honarbakhsh, Shohreh; Srinivasan, Neil; Sawhney, Vinit; Hunter, Ross; Lambiase, Pier

    2018-04-01

    Cardiac resynchronization using a left ventricular (LV) epicardial lead placed in the coronary sinus is now routinely used in the management of heart failure patients. LV endocardial pacing is an alternative when this is not feasible, with outcomes data sparse. To review the available evidence on the efficacy and safety of endocardial LV pacing via meta-analysis. EMBASE, MEDLINE, and COCHRANE databases with the search term "endocardial biventricular pacing" or "endocardial cardiac resynchronization" or "left ventricular endocardial" or "endocardial left ventricular." Comparisons of pre-and post-QRS width, LV ejection fraction (LVEF), and New York Heart Association (NYHA) functional classification was performed, and mean differences (and respective 95% confidence interval [CI]) applied as a measurement of treatment effect. Fifteen studies, including 362 patients, were selected. During a mean follow-up of 40 ± 24.5 months, death occurred in 72 patients (11 per 100 patient-years). Significant improvements in LVEF (mean difference 7.9%, 95% CI 5-10%, P < 0.0001; I 2  = 73%), QRS width (mean difference: -41% 95% -75 to -7%; P < 0.0001; I 2  = 94%), and NYHA class (mean difference: -1.06, 95% CI -1.2 to -0.9, P < 0.0001; I 2  = 60%), (all P < 0.0001) occurred. Stroke rate was 3.3-4.2 per 100 patient-years, which is higher than equivalent heart failure trial populations and recent meta-analysis that included small case series. LV endocardial lead implantation is a potentially efficacious alternative to CS lead placement, but preliminary data suggest a potentially higher risk of stroke during follow-up when compared to the expected incidence of stroke in similar cohorts of patients. © 2018 Wiley Periodicals, Inc.

  13. HEART RATE RECOVERY AFTER EXERCISE AND NEURAL REGULATION OF HEART RATE VARIABILITY IN 30-40 YEAR OLD FEMALE MARATHON RUNNERS

    Directory of Open Access Journals (Sweden)

    Toshio Matsuoka

    2005-03-01

    Full Text Available The aim of the present study was to examine the effects of endurance training on heart rate (HR recovery after exercise and cardiac autonomic nervous system (ANS modulation in female marathon runners by comparing with untrained controls. Six female marathon runners (M group aged 32-40 years and eight age-matched untrained females (C group performed a maximum-effort treadmill running exercise. Maximal oxygen uptake (VO2max was measured during the exercise with a gas analyzer connected to subjects through a face mask. Heart rate, blood pressure and blood lactate were measured before and after the exercise. Rating of perceived exertion (RPE to the exercise was obtained immediately after the exercise. Holter ECG was recorded and analyzed with power spectral analysis of heart rate variability (HRV to investigate the cardiac ANS modulation. The M group had significantly higher VO2max, faster HR recovery after exercise, higher Mean RR, SDRR, HF power and lower LF/HF ratio at rest compared with the C group. The M group also presented greater percent decrease of blood pressure after exercise, although their blood pressure after exercise was higher than the C group. It is suggested that endurance training induced significant alterations in cardiac ANS modulation at rest and significant acceleration of HR recovery after exercise in female marathon runners. Faster HR recovery after exercise in the female marathon runners should result from their higher levels of HRV, higher aerobic capacity and exaggerated blood pressure response to exercise compared with untrained controls.

  14. Heart rate variability based on risk stratification for type 2 diabetes mellitus.

    Science.gov (United States)

    Silva-E-Oliveira, Julia; Amélio, Pâmela Marina; Abranches, Isabela Lopes Laguardia; Damasceno, Dênis Derly; Furtado, Fabianne

    2017-01-01

    To evaluate heart rate variability among adults with different risk levels for type 2 diabetes mellitus. The risk for type 2 diabetes mellitus was assessed in 130 participants (89 females) based on the questionnaire Finnish Diabetes Risk Score and was classified as low risk (n=26), slightly elevated risk (n=41), moderate risk (n=27) and high risk (n=32). To measure heart rate variability, a heart-rate monitor Polar S810i® was employed to obtain RR series for each individual, at rest, for 5 minutes, followed by analysis of linear and nonlinear indexes. The groups at higher risk of type 2 diabetes mellitus had significantly lower linear and nonlinear heart rate variability indexes. The individuals at high risk for type 2 diabetes mellitus have lower heart rate variability. Avaliar a variabilidade da frequência cardíaca em adultos com diferentes níveis de risco para diabetes mellitus tipo 2. O grau de risco para diabetes mellitus tipo 2 de 130 participantes (41 homens) foi avaliado pelo questionário Finnish Diabetes Risk Score. Os participantes foram classificados em baixo risco (n=26), risco levemente elevado (n=41), risco moderado (n=27) e alto risco (n=32). Para medir a variabilidade da frequência cardíaca, utilizou-se o frequencímetro Polar S810i® para obter séries de intervalo RR para cada indivíduo, em repouso, durante 5 minutos; posteriormente, realizou-se análise por meio de índices lineares e não-lineares. O grupo com maior risco para diabetes mellitus tipo 2 teve uma diminuição significante nos índices lineares e não-lineares da variabilidade da frequência cardíaca. Os resultados apontam que indivíduos com risco alto para diabetes mellitus tipo 2 tem menor variabilidade da frequência cardíaca. To evaluate heart rate variability among adults with different risk levels for type 2 diabetes mellitus. The risk for type 2 diabetes mellitus was assessed in 130 participants (89 females) based on the questionnaire Finnish Diabetes Risk Score

  15. Heart rate variability in normal-weight patients with polycystic ovary syndrome.

    Science.gov (United States)

    Kilit, Celal; Paşalı Kilit, Türkan

    2017-05-01

    Polycystic ovary syndrome (PCOS) is an endocrine disease closely related to several risk factors of cardiovascular disease. Obese women with PCOS show altered autonomic modulation. The results of studies investigating cardiac autonomic functions of normal-weight women with PCOS are conflicting. The aim of the study was to assess the reactivity of cardiac sympathovagal balance in normal-weight women with PCOS by heart rate variability analysis. We examined the heart rate variability in 60 normal-weight women with PCOS and compared them with that in 60 age-matched healthy women having a similar metabolic profile. Time and frequency domain parameters of heart rate variability were analyzed based on 5-min-long continuous electrocardiography recordings for the following 3 periods: (1) during rest in supine position, (2) during controlled breathing, and (3) during isometric handgrip exercise. Time and frequency domain parameters of heart rate variability for the 3 periods assessed were similar in the two groups. Although modified Ferriman-Gallwey score and serum testosterone and luteinizing hormone levels were significantly higher in women with PCOS, homeostatic model assessment-insulin resistance (HOMA-IR) was not different the between the PCOS and control groups. There were no significant correlations between serum testosterone levels and heart rate variability parameters among the study population. The findings of this study suggest that the reactivity of cardiac sympathovagal balance is not altered in normal-weight women with PCOS having a normal HOMA-IR.

  16. Abnormal heart rate recovery and deficient chronotropic response after submaximal exercise in young Marfan syndrome patients.

    Science.gov (United States)

    Peres, Paulo; Carvalho, Antônio C; Perez, Ana Beatriz A; Medeiros, Wladimir M

    2016-10-01

    Marfan syndrome patients present important cardiac structural changes, ventricular dysfunction, and electrocardiographic changes. An abnormal heart rate response during or after exercise is an independent predictor of mortality and autonomic dysfunction. The aim of the present study was to compare heart rate recovery and chronotropic response obtained by cardiac reserve in patients with Marfan syndrome subjected to submaximal exercise. A total of 12 patients on β-blocker therapy and 13 off β-blocker therapy were compared with 12 healthy controls. They were subjected to submaximal exercise with lactate measurements. The heart rate recovery was obtained in the first minute of recovery and corrected for cardiac reserve and peak lactate concentration. Peak heart rate (141±16 versus 155±17 versus 174±8 bpm; p=0.001), heart rate reserve (58.7±9.4 versus 67.6±14.3 versus 82.6±4.8 bpm; p=0.001), heart rate recovery (22±6 versus 22±8 versus 34±9 bpm; p=0.001), and heart rate recovery/lactate (3±1 versus 3±1 versus 5±1 bpm/mmol/L; p=0.003) were different between Marfan groups and controls, respectively. All the patients with Marfan syndrome had heart rate recovery values below the mean observed in the control group. The absolute values of heart rate recovery were strongly correlated with the heart rate reserve (r=0.76; p=0.001). Marfan syndrome patients have reduced heart rate recovery and chronotropic deficit after submaximal exercise, and the chronotropic deficit is a strong determinant of heart rate recovery. These changes are suggestive of autonomic dysfunction.

  17. Reduced heart rate variability in social anxiety disorder: associations with gender and symptom severity.

    Directory of Open Access Journals (Sweden)

    Gail A Alvares

    Full Text Available BACKGROUND: Polyvagal theory emphasizes that autonomic nervous system functioning plays a key role in social behavior and emotion. The theory predicts that psychiatric disorders of social dysfunction are associated with reduced heart rate variability, an index of autonomic control, as well as social inhibition and avoidance. The purpose of this study was to examine whether heart rate variability was reduced in treatment-seeking patients diagnosed with social anxiety disorder, a disorder characterized by social fear and avoidance. METHODS: Social anxiety patients (n = 53 were recruited prior to receiving psychological therapy. Healthy volunteers were recruited through the University of Sydney and the general community and were matched by gender and age (n = 53. Heart rate variability was assessed during a five-minute recording at rest, with participants completing a range of self-report clinical symptom measures. RESULTS: Compared to controls, participants with social anxiety exhibited significant reductions across a number of heart rate variability measures. Reductions in heart rate variability were observed in females with social anxiety, compared to female controls, and in patients taking psychotropic medication compared to non-medicated patients. Finally, within the clinical group, we observed significant associations between reduced heart rate variability and increased social interaction anxiety, psychological distress, and harmful alcohol use. CONCLUSIONS: The results of this study confirm that social anxiety disorder is associated with reduced heart rate variability. Resting state heart rate variability may therefore be considered a marker for social approach-related motivation and capacity for social engagement. Additionally, heart rate variability may provide a useful biomarker to explain underlying difficulties with social approach, impaired stress regulation, and behavioral inhibition, especially in disorders associated with

  18. Heart rate and activity profile for young female soccer players

    OpenAIRE

    Barbero Álvarez, José Carlos; Gómez López, Maite; Barbero Álvarez, Verónica; Granda Vera, Juan; Castagna, Carlo

    2008-01-01

    The physical and physiological demands of high-level male soccer have been studied extensively, while few studies have investigated the demands placed on females during match-play, however, there is no information available about the heart rate and activity profile of young female soccer players during match play. Therefore, the aim of this study was to examine cardiovascular (heart-rates HR) and physical demands of young female soccer players during a match. Players were observed during a fr...

  19. Quick detection of QRS complexes and R-waves using a wavelet transform and K-means clustering.

    Science.gov (United States)

    Xia, Yong; Han, Junze; Wang, Kuanquan

    2015-01-01

    Based on the idea of telemedicine, 24-hour uninterrupted monitoring on electrocardiograms (ECG) has started to be implemented. To create an intelligent ECG monitoring system, an efficient and quick detection algorithm for the characteristic waveforms is needed. This paper aims to give a quick and effective method for detecting QRS-complexes and R-waves in ECGs. The real ECG signal from the MIT-BIH Arrhythmia Database is used for the performance evaluation. The method proposed combined a wavelet transform and the K-means clustering algorithm. A wavelet transform is adopted in the data analysis and preprocessing. Then, based on the slope information of the filtered data, a segmented K-means clustering method is adopted to detect the QRS region. Detection of the R-peak is based on comparing the local amplitudes in each QRS region, which is different from other approaches, and the time cost of R-wave detection is reduced. Of the tested 8 records (total 18201 beats) from the MIT-BIH Arrhythmia Database, an average R-peak detection sensitivity of 99.72 and a positive predictive value of 99.80% are gained; the average time consumed detecting a 30-min original signal is 5.78s, which is competitive with other methods.

  20. Music close to one's heart: heart rate variability with music, diagnostic with e-bra and smartphone

    Science.gov (United States)

    Hegde, Shantala; Kumar, Prashanth S.; Rai, Pratyush; Mathur, Gyanesh N.; Varadan, Vijay K.

    2012-04-01

    Music is a powerful elicitor of emotions. Emotions evoked by music, through autonomic correlates have been shown to cause significant modulation of parameters like heart rate and blood pressure. Consequently, Heart Rate Variability (HRV) analysis can be a powerful tool to explore evidence based therapeutic functions of music and conduct empirical studies on effect of musical emotion on heart function. However, there are limitations with current studies. HRV analysis has produced variable results to different emotions evoked via music, owing to variability in the methodology and the nature of music chosen. Therefore, a pragmatic understanding of HRV correlates of musical emotion in individuals listening to specifically chosen music whilst carrying out day to day routine activities is needed. In the present study, we aim to study HRV as a single case study, using an e-bra with nano-sensors to record heart rate in real time. The e-bra developed previously, has several salient features that make it conducive for this study- fully integrated garment, dry electrodes for easy use and unrestricted mobility. The study considers two experimental conditions:- First, HRV will be recorded when there is no music in the background and second, when music chosen by the researcher and by the subject is playing in the background.

  1. Extracting fetal heart beats from maternal abdominal recordings: selection of the optimal principal components

    International Nuclear Information System (INIS)

    Di Maria, Costanzo; Liu, Chengyu; Zheng, Dingchang; Murray, Alan; Langley, Philip

    2014-01-01

    This study presents a systematic comparison of different approaches to the automated selection of the principal components (PC) which optimise the detection of maternal and fetal heart beats from non-invasive maternal abdominal recordings. A public database of 75 4-channel non-invasive maternal abdominal recordings was used for training the algorithm. Four methods were developed and assessed to determine the optimal PC: (1) power spectral distribution, (2) root mean square, (3) sample entropy, and (4) QRS template. The sensitivity of the performance of the algorithm to large-amplitude noise removal (by wavelet de-noising) and maternal beat cancellation methods were also assessed. The accuracy of maternal and fetal beat detection was assessed against reference annotations and quantified using the detection accuracy score F1 [2*PPV*Se / (PPV + Se)], sensitivity (Se), and positive predictive value (PPV). The best performing implementation was assessed on a test dataset of 100 recordings and the agreement between the computed and the reference fetal heart rate (fHR) and fetal RR (fRR) time series quantified. The best performance for detecting maternal beats (F1 99.3%, Se 99.0%, PPV 99.7%) was obtained when using the QRS template method to select the optimal maternal PC and applying wavelet de-noising. The best performance for detecting fetal beats (F1 89.8%, Se 89.3%, PPV 90.5%) was obtained when the optimal fetal PC was selected using the sample entropy method and utilising a fixed-length time window for the cancellation of the maternal beats. The performance on the test dataset was 142.7 beats 2 /min 2 for fHR and 19.9 ms for fRR, ranking respectively 14 and 17 (out of 29) when compared to the other algorithms presented at the Physionet Challenge 2013. (paper)

  2. Increased heart rate variability but normal resting metabolic rate in hypocretin/orexin-deficient human narcolepsy.

    NARCIS (Netherlands)

    Fronczek, R.; Overeem, S.; Reijntjes, R.; Lammers, G.J.; Dijk, J.G.M.; Pijl, H.

    2008-01-01

    STUDY OBJECTIVES: We investigated autonomic balance and resting metabolic rate to explore their possible involvement in obesity in hypocretin/orexin-deficient narcoleptic subjects. METHODS: Resting metabolic rate (using indirect calorimetry) and variability in heart rate and blood pressure were

  3. Vigorous physical activity predicts higher heart rate variability among younger adults.

    Science.gov (United States)

    May, Richard; McBerty, Victoria; Zaky, Adam; Gianotti, Melino

    2017-06-14

    Baseline heart rate variability (HRV) is linked to prospective cardiovascular health. We tested intensity and duration of weekly physical activity as predictors of heart rate variability in young adults. Time and frequency domain indices of HRV were calculated based on 5-min resting electrocardiograms collected from 82 undergraduate students. Hours per week of both moderate and vigorous activity were estimated using the International Physical Activity Questionnaire. In regression analyses, hours of vigorous physical activity, but not moderate activity, significantly predicted greater time domain and frequency domain indices of heart rate variability. Adjusted for weekly frequency, greater daily duration of vigorous activity failed to predict HRV indices. Future studies should test direct measurements of vigorous activity patterns as predictors of autonomic function in young adulthood.

  4. Estimating Energy Expenditure from Heart Rate in Older Adults: A Case for Calibration

    OpenAIRE

    Schrack, Jennifer A.; Zipunnikov, Vadim; Goldsmith, Jeff; Bandeen-Roche, Karen; Crainiceanu, Ciprian M.; Ferrucci, Luigi

    2014-01-01

    Background Accurate measurement of free-living energy expenditure is vital to understanding changes in energy metabolism with aging. The efficacy of heart rate as a surrogate for energy expenditure is rooted in the assumption of a linear function between heart rate and energy expenditure, but its validity and reliability in older adults remains unclear. Objective To assess the validity and reliability of the linear function between heart rate and energy expenditure in older adults using diffe...

  5. Evaluation of therapy for dilated cardiomyopathy with heart failure by iodine-123 metaiodobenzyl-guanidine imaging. Comparison with heart rate variability power spectral analysis

    Energy Technology Data Exchange (ETDEWEB)

    Li, Shou-lin; Ikeda, Jun; Takita, Tamotsu; Sekiguchi, Yohei; Demachi, Jun; Chikama, Hisao; Goto, Atsushi; Shirato, Kunio [Tohoku Univ., Sendai (Japan). School of Medicine

    1998-11-01

    The relationship between the myocardial uptake of iodine-123 metaiodobenzylguanidine ({sup 123}I-MIBG) and heart rate variability parameters has not been determined. This study determined the relationship between the change in myocardial uptake of {sup 123}I-MIBG and improvement in left ventricular function after treatment, to determine the usefulness of {sup 123}I-MIBG imaging to assess the effect of therapy on heart failure due to dilated cardiomyopathy (DCM). {sup 123}I-MIBG imaging and power spectral analysis of heart rate variability were performed before and after treatment in 17 patients with heart failure due to DCM. The following parameters were compared before and after treatment: New York Heart Association (NYHA) functional class, radiographic cardiothoracic ratio (CTR), blood pressure, echocardiographic data (left ventricular end-systolic (LVDs) and end-diastolic (LVDd) diameters, left ventricular ejection fraction (LVEF)), plasma concentrations of norepinephrine and epinephrine, heart rate variability power spectral analysis data (mean low frequency (MLF) and high frequency power (MHF)) and the myocardium to mediastinum activity ratio (MYO/M) obtained in early and late images, and washout rate calculated by anterior planar imaging of {sup 123}I-MIBG. The NYHA functional class, LVEF, LVDs, CTR, MLF and MHF improved after treatment. Early MYO/M and late MYO/M improved after treatment. The rate of increase in late MYO/M was positively correlated with the rate of improvement of LVEF after treatment. Furthermore, the late MYO/M was negatively correlated with MLF. Washout rate revealed no correlation with hemodynamic parameters. These findings suggest that late MYO/M is more useful than washout rate to assess the effect of treatment on heart failure due to DCM. Furthermore, the {sup 123}I-MIBG imaging and heart rate variability parameters are useful to assess the autonomic tone in DCM with heart failure. (author)

  6. Evaluation of therapy for dilated cardiomyopathy with heart failure by iodine-123 metaiodobenzyl-guanidine imaging. Comparison with heart rate variability power spectral analysis

    International Nuclear Information System (INIS)

    Li, Shou-lin; Ikeda, Jun; Takita, Tamotsu; Sekiguchi, Yohei; Demachi, Jun; Chikama, Hisao; Goto, Atsushi; Shirato, Kunio

    1998-01-01

    The relationship between the myocardial uptake of iodine-123 metaiodobenzylguanidine ( 123 I-MIBG) and heart rate variability parameters has not been determined. This study determined the relationship between the change in myocardial uptake of 123 I-MIBG and improvement in left ventricular function after treatment, to determine the usefulness of 123 I-MIBG imaging to assess the effect of therapy on heart failure due to dilated cardiomyopathy (DCM). 123 I-MIBG imaging and power spectral analysis of heart rate variability were performed before and after treatment in 17 patients with heart failure due to DCM. The following parameters were compared before and after treatment: New York Heart Association (NYHA) functional class, radiographic cardiothoracic ratio (CTR), blood pressure, echocardiographic data (left ventricular end-systolic (LVDs) and end-diastolic (LVDd) diameters, left ventricular ejection fraction (LVEF)), plasma concentrations of norepinephrine and epinephrine, heart rate variability power spectral analysis data (mean low frequency (MLF) and high frequency power (MHF)) and the myocardium to mediastinum activity ratio (MYO/M) obtained in early and late images, and washout rate calculated by anterior planar imaging of 123 I-MIBG. The NYHA functional class, LVEF, LVDs, CTR, MLF and MHF improved after treatment. Early MYO/M and late MYO/M improved after treatment. The rate of increase in late MYO/M was positively correlated with the rate of improvement of LVEF after treatment. Furthermore, the late MYO/M was negatively correlated with MLF. Washout rate revealed no correlation with hemodynamic parameters. These findings suggest that late MYO/M is more useful than washout rate to assess the effect of treatment on heart failure due to DCM. Furthermore, the 123 I-MIBG imaging and heart rate variability parameters are useful to assess the autonomic tone in DCM with heart failure. (author)

  7. Effects of candesartan on electrical remodeling in the hearts of inherited dilated cardiomyopathy model mice.

    Directory of Open Access Journals (Sweden)

    Fuminori Odagiri

    Full Text Available Inherited dilated cardiomyopathy (DCM is characterized by dilatation and dysfunction of the ventricles, and often results in sudden death or heart failure (HF. Although angiotensin receptor blockers (ARBs have been used for the treatment of HF, little is known about the effects on postulated electrical remodeling that occurs in inherited DCM. The aim of this study was to examine the effects of candesartan, one of the ARBs, on cardiac function and electrical remodeling in the hearts of inherited DCM model mice (TNNT2 ΔK210. DCM mice were treated with candesartan in drinking water for 2 months from 1 month of age. Control, non-treated DCM mice showed an enlargement of the heart with prolongation of QRS and QT intervals, and died at t1/2 of 70 days. Candesartan dramatically extended the lifespan of DCM mice, suppressed cardiac dilatation, and improved the functional parameters of the myocardium. It also greatly suppressed prolongation of QRS and QT intervals and action potential duration (APD in the left ventricular myocardium and occurrence of ventricular arrhythmia. Expression analysis revealed that down-regulation of Kv4.2 (Ito channel protein, KChIP2 (auxiliary subunit of Kv4.2, and Kv1.5 (IKur channel protein in DCM was partially reversed by candesartan administration. Interestingly, non-treated DCM heart had both normal-sized myocytes with moderately decreased Ito and IKur and enlarged cells with greatly reduced K+ currents (Ito, IKur IK1 and Iss. Treatment with candesartan completely abrogated the emergence of the enlarged cells but did not reverse the Ito, and IKur in normal-sized cells in DCM hearts. Our results indicate that candesartan treatment suppresses structural remodeling to prevent severe electrical remodeling in inherited DCM.

  8. Automatic QRS complex detection algorithm designed for a novel wearable, wireless electrocardiogram recording device

    DEFF Research Database (Denmark)

    Saadi, Dorthe Bodholt; Egstrup, Kenneth; Branebjerg, Jens

    2012-01-01

    We have designed and optimized an automatic QRS complex detection algorithm for electrocardiogram (ECG) signals recorded with the DELTA ePatch platform. The algorithm is able to automatically switch between single-channel and multi-channel analysis mode. This preliminary study includes data from ...

  9. Reliability of heart rate mobile apps in young healthy adults: exploratory study and research directions

    Directory of Open Access Journals (Sweden)

    Maria Parpinel

    2017-06-01

    Full Text Available Background: Recently, a number of smartphone apps appeared that allow for heart rate measurements basing on the photoplethysmography principle. In fact, almost every smartphone now has a camera with flash that could be used for that. Some studies appeared on the reliability of some of those apps, with heterogeneous results. Objectives: The present study aims at adding up evidence in particular during physical activity, by comparing 3 apps on two different platforms (IOs and Android, on a broad range of heart rates. As gold standard, heart rate has been measured with a traditional heart rate monitor. Results: The results suggest that heart rate apps might be used for measuring heart rate for fitness aims for many individuals, but further research is needed to i analyse influence of smartphone features; ii identify personal factors hindering measurements, and iii verify reliability on different measurement sites.

  10. Heart rate profiles and energy cost of locomotion during cross-country skiing races.

    Science.gov (United States)

    Mognoni, P; Rossi, G; Gastaldelli, F; Canclini, A; Cotelli, F

    2001-07-01

    The purpose of this study was to compare heart rate responses and speed in two cross-country skiing races, which were run by seven male and seven female subjects by using classic and free style. Heart rates and skiing velocities were analyzed over flat, uphill and downhill sections, which were run from one to three times. Heart rates were higher in uphill sections than in flat sections; a steady-state heart rate was never reached in the downhill section. When the same uphill section was repeated, the heart rate tended to increase but the speed to decrease. Oxygen uptake (VO2) was calculated from heart rate:VO2 ratio, measured during uphill walking with the aid of poles. The mean (SD) energy cost of locomotion (i.e., the ratio between net VO2 and speed) was 162.1 (9.4) ml.km(-1).kg(-1) and 147.7 (7.1) ml.km(-1).kg(-1) when male subjects ran the flat section after first downhill by using classic and free style, respectively. Females had lower values for VO2 and speed, but similar energy costs. In general, the variability of the energy cost of locomotion in skiers of a similar competitive level is of the same order as that found in uphill walking on a treadmill.

  11. Assessing Metabolic Syndrome Through Increased Heart Rate During Exercise

    Directory of Open Access Journals (Sweden)

    Masoumeh Sadeghi

    2016-12-01

    Full Text Available The present study aimed to assess changes in resting and maximum heart rates as primary indicators of cardiac autonomic function in metabolic syndrome (MetS patients and to determine their value for discriminating MetS from non-MetS. 468 participants were enrolled in this cross-sectional study and assessed according to the updated adult treatment panel III (ATP-III definition of MetS. Resting and maximum heart rates were recorded following the Bruce protocol during an exercise. A receiver operating characteristic (ROC curve was used to identify the best cutoff point for discriminating MetS from the non-MetS state. 194 participants (41.5% were diagnosed as MetS. The mean resting heart rate (RHR was not statistically different between the two groups (P=0.078. However, the mean maximum heart (MHR rate was considerably higher in participants with MetS (142.37±14.84 beats per min compared to the non-MetS group (134.62±21.63 beats per min (P<0.001. In the MetS group, the MHR was positively correlated with the serum triglyceride level (β=0.185, P=0.033 and was inversely associated with age (β=-0.469, P<0.001. The MHR had a moderate value for discriminating MetS from the non-MetS state (c=0.580, P=0.004 with the optimal cutoff point of 140 beats per min. In MetS patients, the MHR was significantly greater compared to non-MetS subjects and was directly correlated with serum triglyceride levels and inversely with advanced age. Moreover, MHR can be used as a suspicious indicator for identifying MetS.

  12. Assessing Metabolic Syndrome Through Increased Heart Rate During Exercise.

    Science.gov (United States)

    Sadeghi, Masoumeh; Gharipour, Mojgan; Nezafati, Pouya; Shafie, Davood; Aghababaei, Esmaeil; Sarrafzadegan, Nizal

    2016-11-01

    The present study aimed to assess changes in resting and maximum heart rates as primary indicators of cardiac autonomic function in metabolic syndrome (MetS) patients and to determine their value for discriminating MetS from non-MetS. 468 participants were enrolled in this cross-sectional study and assessed according to the updated adult treatment panel III (ATP-III) definition of MetS. Resting and maximum heart rates were recorded following the Bruce protocol during an exercise. A receiver operating characteristic (ROC) curve was used to identify the best cutoff point for discriminating MetS from the non-MetS state. 194 participants (41.5%) were diagnosed as MetS. The mean resting heart rate (RHR) was not statistically different between the two groups (P=0.078). However, the mean maximum heart (MHR) rate was considerably higher in participants with MetS (142.37±14.84 beats per min) compared to the non-MetS group (134.62±21.63 beats per min) (P<0.001). In the MetS group, the MHR was positively correlated with the serum triglyceride level (β=0.185, P=0.033) and was inversely associated with age (β=-0.469, P<0.001). The MHR had a moderate value for discriminating MetS from the non-MetS state (c=0.580, P=0.004) with the optimal cutoff point of 140 beats per min. In MetS patients, the MHR was significantly greater compared to non-MetS subjects and was directly correlated with serum triglyceride levels and inversely with advanced age. Moreover, MHR can be used as a suspicious indicator for identifying MetS.

  13. 256-slice CT coronary angiography in atrial fibrillation: The impact of mean heart rate and heart rate variability on image quality

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Liang-Kuang [Department of Radiology, Shin Kong Wu Ho-Su Memorial Hospital, Taipei, Taiwan (China); College of Medicine, Fu Jen Catholic University, Taipei, Taiwan (China); Hsu, Shih-Ming [Department of Biomedical Imaging and Radiological Science, China Medical University, Taichung, Taiwan (China); Mok, Greta S.P. [Department of Electrical and Electronics Engineering, Faculty of Science and Technology, University of Macau, Macau (China); Law, Wei-Yip; Lu, Kun-Mu [Department of Radiology, Shin Kong Wu Ho-Su Memorial Hospital, Taipei, Taiwan (China); Yang, Ching-Ching, E-mail: g39220003@yahoo.com.tw [Department of Radiological Technology, Tzu Chi College of Technology, 880, Sec.2, Chien-kuo Rd. Hualien 970, Taiwan (China); Wu, Tung-Hsin, E-mail: tung@ym.edu.tw [Department of Biomedical Imaging and Radiological Sciences, National Yang Ming University, 155 Li-Nong St., Sec. 2, Taipei 112, Taiwan (China)

    2011-08-21

    Objective: The aim of this study was to evaluate the image quality of 256-MDCT in atrial fibrillation and to compare the findings with those among patients in sinus rhythm. Materials: All reconstructed images were evaluated by two independent experienced readers blinded to patient information, heart rate, and ECG results to assess the diagnostic quality of images of the coronary artery segments using axial images, multi-planar reformations, maximum intensity projections, and volume rendering technique. Results: No statistical significance was detected in terms of the overall image quality between patients in sinus rhythm and with atrial fibrillation. Pearson's correlation analysis showed no significant association between image quality and mean heart rate no matter for patients in sinus rhythm or with atrial fibrillation. Similarly, there was no correlation between image quality and heart rate variability for either patients in sinus rhythm or with atrial fibrillation. Our results showed that the optimal reconstruction window depends on patient's HR, and the pattern for patients in atrial fibrillation is similar to that obtained from non-atrial fibrillation patients. Conclusion: This study shows the potential of using 256-MDCT coronary angiography in patients with atrial fibrillation. Our results suggest that when appropriate reconstruction timing window is applied, patients with atrial fibrillation do not have to be excluded from MDCT coronary angiographic examinations.

  14. 256-slice CT coronary angiography in atrial fibrillation: The impact of mean heart rate and heart rate variability on image quality

    International Nuclear Information System (INIS)

    Chen, Liang-Kuang; Hsu, Shih-Ming; Mok, Greta S.P.; Law, Wei-Yip; Lu, Kun-Mu; Yang, Ching-Ching; Wu, Tung-Hsin

    2011-01-01

    Objective: The aim of this study was to evaluate the image quality of 256-MDCT in atrial fibrillation and to compare the findings with those among patients in sinus rhythm. Materials: All reconstructed images were evaluated by two independent experienced readers blinded to patient information, heart rate, and ECG results to assess the diagnostic quality of images of the coronary artery segments using axial images, multi-planar reformations, maximum intensity projections, and volume rendering technique. Results: No statistical significance was detected in terms of the overall image quality between patients in sinus rhythm and with atrial fibrillation. Pearson's correlation analysis showed no significant association between image quality and mean heart rate no matter for patients in sinus rhythm or with atrial fibrillation. Similarly, there was no correlation between image quality and heart rate variability for either patients in sinus rhythm or with atrial fibrillation. Our results showed that the optimal reconstruction window depends on patient's HR, and the pattern for patients in atrial fibrillation is similar to that obtained from non-atrial fibrillation patients. Conclusion: This study shows the potential of using 256-MDCT coronary angiography in patients with atrial fibrillation. Our results suggest that when appropriate reconstruction timing window is applied, patients with atrial fibrillation do not have to be excluded from MDCT coronary angiographic examinations.

  15. Robust efficient estimation of heart rate pulse from video

    Science.gov (United States)

    Xu, Shuchang; Sun, Lingyun; Rohde, Gustavo Kunde

    2014-01-01

    We describe a simple but robust algorithm for estimating the heart rate pulse from video sequences containing human skin in real time. Based on a model of light interaction with human skin, we define the change of blood concentration due to arterial pulsation as a pixel quotient in log space, and successfully use the derived signal for computing the pulse heart rate. Various experiments with different cameras, different illumination condition, and different skin locations were conducted to demonstrate the effectiveness and robustness of the proposed algorithm. Examples computed with normal illumination show the algorithm is comparable with pulse oximeter devices both in accuracy and sensitivity. PMID:24761294

  16. Mental load, heart rate and heart rate variability.

    NARCIS (Netherlands)

    Blitz, P.S.; Hoogstraten, J.; Mulder, G.

    1970-01-01

    "Several investigators have shown that diminished sinus arrhythmia can be seen as an indication of increased mental load. The present experiment deals with the influence of different levels of mental load, operationalized as the number of binary choices per minute, on the regularity of the heart

  17. Cardiac resynchronization therapy with His bundle pacing as a method of treatment of chronic heart failure in patients with permanent atrial fibrillation and left bundle branch block.

    Science.gov (United States)

    Boczar, Krzysztof; Sławuta, Agnieszka; Ząbek, Andrzej; Dębski, Maciej; Gajek, Jacek; Lelakowski, Jacek; Małecka, Barbara

    CRT is a therapeutic option for patients with heart failure, sinus rhythm, prolonged QRS complex duration and reduced ejection fraction. We present a case of 71-year-old woman with dilated cardiomyopathy, NYHA functional class III and AF. We implanted CRT combined with direct His-bundle pacing. The indication for such a therapy was a left bundle branch block with a QRS complex of 178ms and a left ventricular EF of 15%, left ventricular end-diastolic diameter (LVEDD) of 75mm. After 8months of follow-up the LVEDD was 60mm with EF 35-40%. Copyright © 2017. Published by Elsevier Inc.

  18. Electrocardiogram application based on heart rate variability ontology and fuzzy markup language

    NARCIS (Netherlands)

    Wang, M.-H.; Lee, C.-S.; Acampora, G.; Loia, V.; Gacek, A.; Pedrycz, W.

    2011-01-01

    The electrocardiogram (ECG) signal is adopted extensively as a low-cost diagnostic procedure to provide information concerning the healthy status of the heart. Heart rate variability (HRV) is a physiological phenomenon where the time interval between heart beats varies. It is measured by the

  19. Heart Rates of Elementary Physical Education Students during the Dancing Classrooms Program

    Science.gov (United States)

    Nelson, Larry; Evans, Melissa; Guess, Wendy; Morris, Mary; Olson, Terry; Buckwalter, John

    2011-01-01

    We examined how different types of dance activities, along with their duration, influenced heart rate responses among fifth-grade physical education students (N = 96) who participated in the Dancing Classrooms program. Results indicated that the overall Dancing Classrooms program elicits a moderate cardiovascular heart rate response (M = 124.4…

  20. Heart rate variability and heart rate turbulence in patients with polycystic ovary syndrome.

    Science.gov (United States)

    Özkeçeci, Gülay; Ünlü, Bekir Serdar; Dursun, Hüseyin; Akçi, Önder; Köken, Gülengül; Onrat, Ersel; Avşar, Alaettin

    2016-05-01

    Cardiac autonomic dysfunction may develop in patients with polycystic ovary syndrome (PCOS). Heart rate variability (HRV) and heart rate turbulence (HRT) are used in assessing cardiac autonomic functions. The goal of this study was to compare the cardiac autonomic functions in patients with PCOS and healthy controls. To our knowledge, this is the first study evaluating cardiac autonomic functions in patients with PCOS with respect to both HRV and HRT. Twenty-three patients with PCOS (mean age 22.8±3.9 years) and 25 healthy female volunteers who were matched for age and body mass index (BMI) (mean age 23.5±6.2 years) were enrolled in this as case-control study. Twenty-four hour ambulatory electrocardiogram recordings of all participants were taken using Pathfinder software. The time domain parameters of HRV and HRT, including turbulence onset (TO) and turbulence slope, were calculated. Diagnosis of PCOS was made with physical and laboratory findings of hirsutism or biochemical hyperandrogenism and chronic anovulation. Diabetes mellitus, other hormon disorders or hormon therapy, pregnancy, atrial fibrilation, obesite, chronic diseases, disorders of the autonomic nervous system, a history of drug use affecting the autonomic nervous system were excluded. There were no significant differences in HRV and HRT parameters between the two groups. Cardiovascular risk factors, such as BMI, blood pressure, fasting blood glucose, and lipid parameters, were also similar. Triangular index measure of HRV was negatively correlated with high density lipoprotein cholesterol levels (r=-0.47, p<0.05), while age and BMI were significantly correlated with TO (r=0.31 and 0.47, respectively; p<0.05 for all). Cardiac autonomic functions were not found to be altered in patients with PCOS in comparison with healthy controls. These results may be explained with the absence of concomitant cardiovascular risk factors with the patients being in the early stage of the disease.

  1. Heart Rate Measures of Flight Test and Evaluation

    National Research Council Canada - National Science Library

    Bonner, Malcolm A; Wilson, Glenn F

    2001-01-01

    .... Because flying is a complex task, several measures are required to derive the best evaluation. This article describes the use of heart rate to augment the typical performance and subjective measures used in test and evaluation...

  2. Office and 24-hour heart rate and target organ damage in hypertensive patients

    Directory of Open Access Journals (Sweden)

    García-García Ángel

    2012-03-01

    Full Text Available Abstract Background We investigated the association between heart rate and its variability with the parameters that assess vascular, renal and cardiac target organ damage. Methods A cross-sectional study was performed including a consecutive sample of 360 hypertensive patients without heart rate lowering drugs (aged 56 ± 11 years, 64.2% male. Heart rate (HR and its standard deviation (HRV in clinical and 24-hour ambulatory monitoring were evaluated. Renal damage was assessed by glomerular filtration rate and albumin/creatinine ratio; vascular damage by carotid intima-media thickness and ankle/brachial index; and cardiac damage by the Cornell voltage-duration product and left ventricular mass index. Results There was a positive correlation between ambulatory, but not clinical, heart rate and its standard deviation with glomerular filtration rate, and a negative correlation with carotid intima-media thickness, and night/day ratio of systolic and diastolic blood pressure. There was no correlation with albumin/creatinine ratio, ankle/brachial index, Cornell voltage-duration product or left ventricular mass index. In the multiple linear regression analysis, after adjusting for age, the association of glomerular filtration rate and intima-media thickness with ambulatory heart rate and its standard deviation was lost. According to the logistic regression analysis, the predictors of any target organ damage were age (OR = 1.034 and 1.033 and night/day systolic blood pressure ratio (OR = 1.425 and 1.512. Neither 24 HR nor 24 HRV reached statistical significance. Conclusions High ambulatory heart rate and its variability, but not clinical HR, are associated with decreased carotid intima-media thickness and a higher glomerular filtration rate, although this is lost after adjusting for age. Trial Registration ClinicalTrials.gov: NCT01325064

  3. Effect of Heart rate on Basketball Three-Point Shot Accuracy

    Directory of Open Access Journals (Sweden)

    Luca P. Ardigò

    2018-02-01

    Full Text Available The three-point shot (3S is a fundamental basketball skill used frequently during a game, and is often a main determinant of the final result. The aim of the study was to investigate the effect of different metabolic conditions, in terms of heart rates, on 3S accuracy (3S% in 24 male (Under 17 basketball players (age 16.3 ± 0.6 yrs. 3S performance was specifically investigated at different heart rates. All sessions consisted of 10 consecutive 3Ss from five different significant field spots just beyond the FIBA three-point line, i.e., about 7 m from the basket (two counter-clockwise “laps” at different heart rates: rest (0HR, after warm-up (50%HRMAX [50HR], and heart rate corresponding to 80% of its maximum value (80%HRMAX [80HR]. We found that 50HR does not significantly decrease 3S% (−15%, P = 0.255, while 80HR significantly does when compared to 0HR (−28%, P = 0.007. Given that 50HR does not decrease 3S% compared to 0HR, we believe that no preliminary warm-up is needed before entering a game in order to specifically achieve a high 3S%. Furthermore, 3S training should be performed in conditions of moderate-to-high fatigued state so that a high 3S% can be maintained during game-play.

  4. An open-source LabVIEW application toolkit for phasic heart rate analysis in psychophysiological research.

    Science.gov (United States)

    Duley, Aaron R; Janelle, Christopher M; Coombes, Stephen A

    2004-11-01

    The cardiovascular system has been extensively measured in a variety of research and clinical domains. Despite technological and methodological advances in cardiovascular science, the analysis and evaluation of phasic changes in heart rate persists as a way to assess numerous psychological concomitants. Some researchers, however, have pointed to constraints on data analysis when evaluating cardiac activity indexed by heart rate or heart period. Thus, an off-line application toolkit for heart rate analysis is presented. The program, written with National Instruments' LabVIEW, incorporates a variety of tools for off-line extraction and analysis of heart rate data. Current methods and issues concerning heart rate analysis are highlighted, and how the toolkit provides a flexible environment to ameliorate common problems that typically lead to trial rejection is discussed. Source code for this program may be downloaded from the Psychonomic Society Web archive at www.psychonomic.org/archive/.

  5. Cardiovascular Reactivity and Heart Rate Variability in Panic Disorder

    National Research Council Canada - National Science Library

    Santiago, Helen T

    1999-01-01

    .... Because previous studies of cardiovascular reactivity and heart rate variability have been inconclusive, these factors were re-examined in panickers and controls during physiological challenge...

  6. The effect of orthostatic stress on multiscale entropy of heart rate and blood pressure

    International Nuclear Information System (INIS)

    Turianikova, Zuzana; Javorka, Kamil; Calkovska, Andrea; Javorka, Michal; Baumert, Mathias

    2011-01-01

    Cardiovascular control acts over multiple time scales, which introduces a significant amount of complexity to heart rate and blood pressure time series. Multiscale entropy (MSE) analysis has been developed to quantify the complexity of a time series over multiple time scales. In previous studies, MSE analyses identified impaired cardiovascular control and increased cardiovascular risk in various pathological conditions. Despite the increasing acceptance of the MSE technique in clinical research, information underpinning the involvement of the autonomic nervous system in the MSE of heart rate and blood pressure is lacking. The objective of this study is to investigate the effect of orthostatic challenge on the MSE of heart rate and blood pressure variability (HRV, BPV) and the correlation between MSE (complexity measures) and traditional linear (time and frequency domain) measures. MSE analysis of HRV and BPV was performed in 28 healthy young subjects on 1000 consecutive heart beats in the supine and standing positions. Sample entropy values were assessed on scales of 1–10. We found that MSE of heart rate and blood pressure signals is sensitive to changes in autonomic balance caused by postural change from the supine to the standing position. The effect of orthostatic challenge on heart rate and blood pressure complexity depended on the time scale under investigation. Entropy values did not correlate with the mean values of heart rate and blood pressure and showed only weak correlations with linear HRV and BPV measures. In conclusion, the MSE analysis of heart rate and blood pressure provides a sensitive tool to detect changes in autonomic balance as induced by postural change

  7. Heart Disease Death Rates Among Blacks and Whites Aged ≥35 Years - United States, 1968-2015.

    Science.gov (United States)

    Van Dyke, Miriam; Greer, Sophia; Odom, Erika; Schieb, Linda; Vaughan, Adam; Kramer, Michael; Casper, Michele

    2018-03-30

    Heart disease is the leading cause of death in the United States. In 2015, heart disease accounted for approximately 630,000 deaths, representing one in four deaths in the United States. Although heart disease death rates decreased 68% for the total population from 1968 to 2015, marked disparities in decreases exist by race and state. 1968-2015. The National Vital Statistics System (NVSS) data on deaths in the United States were abstracted for heart disease using diagnosis codes from the eighth, ninth, and tenth revisions of the International Classification of Diseases (ICD-8, ICD-9, and ICD-10) for 1968-2015. Population estimates were obtained from NVSS files. National and state-specific heart disease death rates for the total population and by race for adults aged ≥35 years were calculated for 1968-2015. National and state-specific black-white heart disease mortality ratios also were calculated. Death rates were age standardized to the 2000 U.S. standard population. Joinpoint regression was used to perform time trend analyses. From 1968 to 2015, heart disease death rates decreased for the total U.S. population among adults aged ≥35 years, from 1,034.5 to 327.2 per 100,000 population, respectively, with variations in the magnitude of decreases by race and state. Rates decreased for the total population an average of 2.4% per year, with greater average decreases among whites (2.4% per year) than blacks (2.2% per year). At the national level, heart disease death rates for blacks and whites were similar at the start of the study period (1968) but began to diverge in the late 1970s, when rates for blacks plateaued while rates for whites continued to decrease. Heart disease death rates among blacks remained higher than among whites for the remainder of the study period. Nationwide, the black-white ratio of heart disease death rates increased from 1.04 in 1968 to 1.21 in 2015, with large increases occurring during the 1970s and 1980s followed by small but steady

  8. Effect of Heart rate on Basketball Three-Point Shot Accuracy

    OpenAIRE

    Luca P. Ardigò; Goran Kuvacic; Antonio D. Iacono; Giacomo Dascanio; Johnny Padulo; Johnny Padulo

    2018-01-01

    The three-point shot (3S) is a fundamental basketball skill used frequently during a game, and is often a main determinant of the final result. The aim of the study was to investigate the effect of different metabolic conditions, in terms of heart rates, on 3S accuracy (3S%) in 24 male (Under 17) basketball players (age 16.3 ± 0.6 yrs). 3S performance was specifically investigated at different heart rates. All sessions consisted of 10 consecutive 3Ss from five different significant field spot...

  9. Heart rate-based lactate minimum test: a reproducible method.

    NARCIS (Netherlands)

    Strupler, M.; Muller, G.; Perret, C.

    2009-01-01

    OBJECTIVE: To find the individual intensity for aerobic endurance training, the lactate minimum test (LMT) seems to be a promising method. LMTs described in the literature consist of speed or work rate-based protocols, but for training prescription in daily practice mostly heart rate is used. The

  10. Heart rate variability analysis in healthy subjects, patients suffering from congestive heart failure and heart transplanted patients

    Directory of Open Access Journals (Sweden)

    Argentina Leite

    2013-12-01

    Full Text Available This study aimed to find parameters to characterize heart rate variability (HRV and discriminate healthy subjects and patients with heart diseases. The parameters used for discrimination characterize the different components of HRV memory (short and long and are extracted from HRV recordings using parametric as well as non parametric methods. Thus, the parameters are: spectral components at low frequencies (LH and high frequencies (HF which are associated with the short memory of HRV and the long memory parameter (d obtained from autoregressive fractionally integrated moving average (ARFIMA models. In the non parametric context, short memory (α1 and long memory (α2 parameters are obtained from detrended fluctuation analysis (DFA. The sample used in this study contains 24-hour Holter HRV recordings of 30 subjects: 10 healthy individuals, 10 patients suffering from congestive heart failure and 10 heart transplanted patients from the Noltisalis database. It was found that short memory parameters present higher values for the healthy individuals whereas long memory parameters present higher values for the diseased individuals. Moreover, there is evidence that ARFIMA modeling allows the discrimination between the 3 groups under study, being advantageous over DFA.

  11. Effect of atrioventricular conduction on heart rate variability

    KAUST Repository

    Ahmad, Talha Jamal; Ali, Hussnain; Majeed, S. M Imran; Khan, Shoab A.

    2011-01-01

    This paper discusses the effect of atrioventricular conduction time (AVCT) on the short-term Heart Rate Variability (HRV) by computing HRV parameters using intervals between the onsets of successive P waves (PP time series) for three groups: normal

  12. Hopfield neural network and optical fiber sensor as intelligent heart rate monitor

    Science.gov (United States)

    Mutter, Kussay Nugamesh

    2018-01-01

    This paper presents a design and fabrication of an intelligent fiber-optic sensor used for examining and monitoring heart rate activity. It is found in the literature that the use of fiber sensors as heart rate sensor is widely studied. However, the use of smart sensors based on Hopfield neural networks is very low. In this work, the sensor is a three fibers without cladding of about 1 cm, fed by laser light of 1550 nm of wavelength. The sensing portions are mounted with a micro sensitive diaphragm to transfer the pulse pressure on the left radial wrist. The influenced light intensity will be detected by a three photodetectors as inputs into the Hopfield neural network algorithm. The latter is a singlelayer auto-associative memory structure with a same input and output layers. The prior training weights are stored in the net memory for the standard recorded normal heart rate signals. The sensors' heads work on the reflection intensity basis. The novelty here is that the sensor uses a pulse pressure and Hopfield neural network in an integrity approach. The results showed a significant output measurements of heart rate and counting with a plausible error rate.

  13. A 410-nW Efficient QRS Processor for Mobile ECG Monitoring in 0.18-μm CMOS.

    Science.gov (United States)

    Li, Peng; Zhang, Xu; Liu, Ming; Hu, Xiaohui; Pang, Bo; Yao, Zhaolin; Jiang, Hanjun; Chen, Hongda

    2017-12-01

    This paper proposes a low power and efficient QRS processor for real-time and continuous mobile ECG monitoring. The QRS detector contains the wavelet transform (WT), the modulus maxima pair identification (MMPI), and the R position modification (RPM). In order to reduce power consumption, we choose the Haar function as the mother wavelet of WT. It is implemented by an optimized FIR filter structure where none of the multiplier is used. The MMPI processes the wavelet coefficients at scale 2 4 and provides candidate R peak positions for the RPM. To improve the accuracy and robust performance, a number of modules have been designed in MMPI, including the preprocessing unit, the automatic threshold updating, and the decision state machine. The RPM is designed to eliminate digital time delay in wavelet transform and locate the R peak position precisely. Raw ECG signals and QRS detection results are output simultaneously. Fabricated in 0.18-μm N-well CMOS 1P6M technology, the power consumption of this chip is only about 410 nW in 1 V voltage supply. Validated by all 48 sets of data in the MIT-BIH arrhythmia database, the sensitive and the positive prediction are 99.60% and 99.77% respectively.

  14. Variation in heart rate influences the assessment of transient ischemic dilation in myocardial perfusion scintigraphy

    International Nuclear Information System (INIS)

    Leslie, William D; Levin, Daniel P; Demeter, Sandor J

    2007-01-01

    Transient arrhythmias can affect transient ischemic dilation (TID) ratios. This study was initiated to evaluate the frequency and effect of normal heart rate change on TID measures in routine clinical practice. Consecutive patients undergoing stress/rest sestamibi gated myocardial perfusion scintigraphy were studied (N = 407). Heart rate at the time of stress and rest imaging were recorded. TID ratios were analyzed in relation to absolute change in heart rate (stress minus rest) for subjects with normal perfusion and systolic function (Group 1, N = 169) and those with abnormalities in perfusion and/or function (Group 2, N = 238). In Group 1, mean TID ratio was inversely correlated with the change in heart rate (r = -0.47, P < 0.0001). For every increase of 10 BPM in heart rate change, the TID ratio decreased by approximately 0.06 (95% confidence interval 0.04–0.07). In Group 2, multiple linear regression demonstrated that the change in heart rate (beta = -0.25, P < 0.0001) and the summed difference score (beta = 0.36, P < 0.0001) were independent predictors of the TID ratio. Normal variation in heart rate between the stress and rest components of myocardial perfusion scans is common and can influence TID ratios in patients with normal and abnormal cardiac scans

  15. gHRV: Heart rate variability analysis made easy.

    Science.gov (United States)

    Rodríguez-Liñares, L; Lado, M J; Vila, X A; Méndez, A J; Cuesta, P

    2014-08-01

    In this paper, the gHRV software tool is presented. It is a simple, free and portable tool developed in python for analysing heart rate variability. It includes a graphical user interface and it can import files in multiple formats, analyse time intervals in the signal, test statistical significance and export the results. This paper also contains, as an example of use, a clinical analysis performed with the gHRV tool, namely to determine whether the heart rate variability indexes change across different stages of sleep. Results from tests completed by researchers who have tried gHRV are also explained: in general the application was positively valued and results reflect a high level of satisfaction. gHRV is in continuous development and new versions will include suggestions made by testers. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  16. Using a smartphone to measure heart rate changes during relived happiness and anger

    NARCIS (Netherlands)

    Lakens, D.

    2013-01-01

    This study demonstrates the feasibility of measuring heart rate differences associated with emotional states such as anger and happiness with a smartphone. Novice experimenters measured higher heart rates during relived anger and happiness (replicating findings in the literature) outside a

  17. Automatic heart rate normalization for accurate energy expenditure normalization : an analysis of activities of daily living and heart rate features

    NARCIS (Netherlands)

    Altini, M.; Penders, J.; Vullers, R.J.M.; Amft, O.D.

    2014-01-01

    Introduction: This article is part of the Focus Theme of Methods of Information in Medicine on "Pervasive Intelligent Technologies for Health". Background: Energy Expenditure (EE) estimation algorithms using Heart Rate (HR) or a combination of accelerometer and HR data suffer from large error due to

  18. Effect of the Torrance Creative Thinking Test on Heart Rate Signal Features

    Directory of Open Access Journals (Sweden)

    Zakeri S.

    2016-02-01

    Full Text Available Aims: Showing a meta-cognitive aspect, creativity is related to higher mental processes such as thinking, intelligence, imagination, and information process. There are many studies on the physiological bases of creativity. The aim of this study was to investigate the effects of creative thinking on the heart rate signal. Materials & Methods: In this semi-experimental study, 52 medical engineering, electrical, and control students of Sahand University were studied in 2012. The subjects were selected via accessible sampling method. To assess the level of the students’ creative thinking, Torrance Tests of Creative Thinking (B form; figural was used. Before and during creative thinking test, heart signal in the rest position was recorded by 1000Hz sampling frequency. Data was analyzed using Wilcoxon non-parametric test.   Findings: There was an increase in the mean heart power amplitude during creative thinking than the rest position. However, passing time and conducting the last sessions of the creativity test, it showed a reduction. There was an increase in the heart rate in persons with high creativity than those with low creativity. In addition, based on the test scores, there was a higher creativity level in females and three-lingual persons than males and bi-lingual persons, respectively. There was an increase in the heart rate in females than males (p=0.0398. Nevertheless, there was no significant difference between three-lingual and bilingual persons (p>0.05.    Conclusion: Creative thinking results in an increase in the heart rate in persons with high creativity than persons with low creativity. Therefore, the creativity level can be detected via heart signal. 

  19. Heart rate variability in normal-weight patients with polycystic ovary syndrome

    OpenAIRE

    Kilit, Celal; Kilit, T?rkan Pa?al?

    2017-01-01

    Objective: Polycystic ovary syndrome (PCOS) is an endocrine disease closely related to several risk factors of cardiovascular disease. Obese women with PCOS show altered autonomic modulation. The results of studies investigating cardiac autonomic functions of normal-weight women with PCOS are conflicting. The aim of the study was to assess the reactivity of cardiac sympathovagal balance in normal-weight women with PCOS by heart rate variability analysis. Methods: We examined the heart rate va...

  20. Early warnings of heart rate deterioration

    OpenAIRE

    Almeida, Vânia G.; Nabney, Ian T.

    2016-01-01

    Hospitals can experience difficulty in detecting and responding to early signs of patient deterioration leading to late intensive care referrals, excess mortality and morbidity, and increased hospital costs. Our study aims to explore potential indicators of physiological deterioration by the analysis of vital-signs. The dataset used comprises heart rate (HR) measurements from MIMIC II waveform database, taken from six patients admitted to the Intensive Care Unit (ICU) and diagnosed with sever...

  1. Continuous measurement of heart rate variability following carbon ...

    African Journals Online (AJOL)

    Background: Previous studies of autonomic nervous system activity through analysis of heart rate variability (HRV) have demonstrated increased sympathetic activity during positive-pressure pneumoperitoneum. We employed an online, continuous method for rapid HRV analysis (MemCalc™, Tarawa, Suwa Trust, Tokyo, ...

  2. Endogenous Pain Modulation: Association with Resting Heart Rate Variability and Negative Affectivity.

    Science.gov (United States)

    Van Den Houte, Maaike; Van Oudenhove, Lukas; Bogaerts, Katleen; Van Diest, Ilse; Van den Bergh, Omer

    2017-07-21

    Several chronic pain syndromes are characterized by deficient endogenous pain modulation as well as elevated negative affectivity and reduced resting heart rate variability. In order to elucidate the relationships between these characteristics, we investigated whether negative affectivity and heart rate variability are associated with endogenous pain modulation in a healthy population. An offset analgesia paradigm with noxious thermal stimulation calibrated to the individual's pain threshold was used to measure endogenous pain modulation magnitude in 63 healthy individuals. Pain ratings during constant noxious heat stimulation to the arm (15 seconds) were compared with ratings during noxious stimulation comprising a 1 °C rise and return of temperature to the initial level (offset trials, 15 seconds). Offset analgesia was defined as the reduction in pain following the 1 °C decrease relative to pain at the same time point during continuous heat stimulation. Evidence for an offset analgesia effect could only be found when noxious stimulation intensity (and, hence, the individual's pain threshold) was intermediate (46 °C or 47 °C). Offset analgesia magnitude was also moderated by resting heart rate variability: a small but significant offset effect was found in participants with high but not low heart rate variability. Negative affectivity was not related to offset analgesia magnitude. These results indicate that resting heart rate variability (HRV) is related to endogenous pain modulation (EPM) in a healthy population. Future research should focus on clarifying the causal relationship between HRV and EPM and chronic pain by using longitudinal study designs. © 2017 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  3. Incident solar radiation and coronary heart disease mortality rates in Europe

    International Nuclear Information System (INIS)

    Wong, Alfred

    2008-01-01

    The reported low mortality rate from coronary heart disease in Portugal, Spain, Italy, Greece, and France, to a lesser extent, has been attributed in numerous nutritional studies to the consumption of a Mediterranean-type diet. There are still many unresolved issues about the direct causal effect of the Mediterranean dietary regime on low incidence of coronary heart disease. An analysis of coronary heart disease mortality rates in Europe from a latitudinal gradient perspective has shown to have a close correlation to incident solar radiation. It is surmised that the resulting increased in situ biosynthesis of Vitamin D 3 could be the critical missing confounder in the analysis of the beneficial health outcome of the Mediterranean diet

  4. Effect of pre operative heart rate on post spinal hypotension in obsteric patients

    International Nuclear Information System (INIS)

    Khan, S.; Zahoor, M.U.; Zaid, A.Y.; Buland, K.

    2010-01-01

    The purpose of the study was to determine the association between of preoperative heart rate and post spinal hypotension in women undergoing cesarean section, Two hundred patients undergoing caesarean were included in the study selected on non probability convenience sampling technique, The patients were divided into two groups depending upon their pre operative heart rate. Spinal anesthesia was administered and number of patients developing hypotension was noted. Among 200 patients, who were included in the study; 112 were placed in group A and 88 were placed in group B depending on mean heart rate of 90 beats per minute or less or 91 beats per minute or more respectively. In group A 14 (11.86%) patients developed hypotension where as in group B 28 (31,82%) patients developed hypotension. Pre operative heart rate is significantly associated with post spinal hypotension in obstetric patients undergoing cesarean section. (author)

  5. Design of a heart rate controller for treadmill exercise using a recurrent fuzzy neural network.

    Science.gov (United States)

    Lu, Chun-Hao; Wang, Wei-Cheng; Tai, Cheng-Chi; Chen, Tien-Chi

    2016-05-01

    In this study, we developed a computer controlled treadmill system using a recurrent fuzzy neural network heart rate controller (RFNNHRC). Treadmill speeds and inclines were controlled by corresponding control servo motors. The RFNNHRC was used to generate the control signals to automatically control treadmill speed and incline to minimize the user heart rate deviations from a preset profile. The RFNNHRC combines a fuzzy reasoning capability to accommodate uncertain information and an artificial recurrent neural network learning process that corrects for treadmill system nonlinearities and uncertainties. Treadmill speeds and inclines are controlled by the RFNNHRC to achieve minimal heart rate deviation from a pre-set profile using adjustable parameters and an on-line learning algorithm that provides robust performance against parameter variations. The on-line learning algorithm of RFNNHRC was developed and implemented using a dsPIC 30F4011 DSP. Application of the proposed control scheme to heart rate responses of runners resulted in smaller fluctuations than those produced by using proportional integra control, and treadmill speeds and inclines were smoother. The present experiments demonstrate improved heart rate tracking performance with the proposed control scheme. The RFNNHRC scheme with adjustable parameters and an on-line learning algorithm was applied to a computer controlled treadmill system with heart rate control during treadmill exercise. Novel RFNNHRC structure and controller stability analyses were introduced. The RFNNHRC were tuned using a Lyapunov function to ensure system stability. The superior heart rate control with the proposed RFNNHRC scheme was demonstrated with various pre-set heart rates. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  6. Activity and heart rate in semi-domesticated reindeer during adaptation to emergency feeding.

    Science.gov (United States)

    Nilsson, A; Ahman, B; Norberg, H; Redbo, I; Eloranta, E; Olsson, K

    2006-06-15

    Although reindeer are well adapted to limited food resources during winter, semi-domesticated reindeer are regularly fed when snow conditions are bad in order to prevent starvation. Feeding sometimes results in health problems and loss of animals. This study was made to assess if activity pattern in reindeer could be used as a tool for the reindeer herder in early detection of animals that are not adapting to feeding. The frequency of 10 behavioural categories was recorded in five groups of penned, eight-month-old, female semi-domesticated reindeer. Three reindeer per group were fitted with heart rate monitors. Lying was the most frequent behaviour, whilst there were few cases of agonistic behaviour. Heart rate varied during the day, with peaks during feeding and low heart rates in the early morning. Restricted feed intake resulted in more locomotion and seeking but less ruminating compared to feeding ad libitum. This was followed by a generally lower heart rate in reindeer in the restricted groups compared to controls. Subsequent feeding with different combinations of lichens, silage and pellets ad libitum resulted initially in significantly more of the animals lying curled up, compared to controls, combined with increased heart rates. As the experiment continued the general activity pattern, as well as the heart rate, gradually became more similar in all groups. Lying curled was the behavioural indicator most consistently affected by feed deprivation and adaptation to feeding and may thus be a useful indicator to distinguish individual reindeer that are not adjusting to feeding.

  7. Cardiac Rehabilitation Improves the QRS Fragmentation in Patients With ST Elevatıon Myocardial Infarction

    Directory of Open Access Journals (Sweden)

    Mustafa Bulut

    2015-09-01

    Conclusion: The existence of the fQRS decreases after CR in patients with STEMI especially in hypertensive individuals, which may be related to improved electrical stability in the myocardium as a predictor of increase in survival and decrease in major cardiac events.

  8. Changes in heart rate associated with contest outcome in agonistic encounters in lobsters.

    Science.gov (United States)

    Hernáindez-Falcón, Jesús; Basu, Alo C; Govindasamy, Siddhartan; Kravitz, Edward A

    2005-03-01

    Agonistic contests between lobsters housed together in a confined space progress through encounters of increasing intensity until a dominance relationship is established. Once this relationship is established, losing animals continually retreat from the advances of winners. These encounters are likely to consume much energy in both winning and losing animals. Therefore, one might expect involvement of many physiological systems before, during and after fights. Here, we report effects of agonistic encounters on cardiac frequency in winning and losing adult lobsters involved in dyadic interactions. The results show that: (i) small but significant increases in heart rate are observed upon chemical detection of a conspecific; (ii) during agonistic interactions, further increases in heart rate are seen; and (iii) ultimate winners exhibit greater increases in heart rate lasting longer periods of time compared to ultimate losers. Heart rate in winners remains elevated for at least 15 min after the contests have ended and animals have been returned to their home tanks. Reduced effects are seen in second and third pairings between familiar opponents. The sustained changes in heart rate that we observe in winning lobsters may result from hormonal modulation of cardiac function related to the change in social status brought about by contest outcome.

  9. Comparative evaluation of heart rate-based monitors: Apple Watch vs Fitbit Charge HR.

    Science.gov (United States)

    Bai, Yang; Hibbing, Paul; Mantis, Constantine; Welk, Gregory J

    2018-08-01

    The purpose of this investigation was to examine the validity of energy expenditure (EE), steps, and heart rate measured with the Apple Watch 1 and Fitbit Charge HR. Thirty-nine healthy adults wore the two monitors while completing a semi-structured activity protocol consisting of 20 minutes of sedentary activity, 25 minutes of aerobic exercise, and 25 minutes of light intensity physical activity. Criterion measures were obtained from an Oxycon Mobile for EE, a pedometer for steps, and a Polar heart rate strap worn on the chest for heart rate. For estimating whole-trial EE, the mean absolute percent error (MAPE) from Fitbit Charge HR (32.9%) was more than twice that of Apple Watch 1 (15.2%). This trend was consistent for the individual conditions. Both monitors accurately assessed steps during aerobic activity (MAPE Apple : 6.2%; MAPE Fitbit : 9.4%) but overestimated steps in light physical activity. For heart rate, Fitbit Charge HR produced its smallest MAPE in sedentary behaviors (7.2%), followed by aerobic exercise (8.4%), and light activity (10.1%). The Apple Watch 1 had stronger validity than the Fitbit Charge HR for assessing overall EE and steps during aerobic exercise. The Fitbit Charge HR provided heart rate estimates that were statistically equivalent to Polar monitor.

  10. Embryos in the fast lane: high-temperature heart rates of turtles decline after hatching.

    Directory of Open Access Journals (Sweden)

    Wei-Guo Du

    Full Text Available In ectotherms such as turtles, the relationship between cardiovascular function and temperature may be subject to different selective pressures in different life-history stages. Because embryos benefit by developing as rapidly as possible, and can "afford" to expend energy to do so (because they have access to the yolk for nutrition, they benefit from rapid heart (and thus, developmental rates. In contrast, hatchlings do not have a guaranteed food supply, and maximal growth rates may not enhance fitness--and so, we might expect a lower heart rate, especially at high temperatures where metabolic costs are greatest. Our data on two species of emydid turtles, Chrysemys picta, and Graptemys pseudogeographica kohnii, support these predictions. Heart rates of embryos and hatchlings were similar at low temperatures, but heart rates at higher temperatures were much greater before than after hatching.

  11. Continuous measurement of heart rate variability following carbon ...

    African Journals Online (AJOL)

    2010-07-16

    Jul 16, 2010 ... Power spectral analysis of the electrocardiographic R-R interval [heart rate variability: (HRV)] is a well known, non- invasive method for assessing autonomic nervous activity.1. Studies using HRV analysis during positive-pressure pneumoperitoneum (PPP) have demonstrated increased sympathetic ...

  12. Universal design of a microcontroller and IoT system to detect the heart rate

    Science.gov (United States)

    Uwamahoro, Raphael; Mushikiwabeza, Alexie; Minani, Gerard; Mohan Murari, Bhaskar

    2017-11-01

    Heart rate analysis provides vital information of the present condition of the human body. It helps medical professionals in diagnosis of various malfunctions of the body. The limitation of vision impaired and blind people to access medical devices cause a considerable loss of life. In this paper, we intended to develop a heart rate detection system that is usable for people with normal and abnormal vision. The system is based on a non-invasive method of measuring the variation of the tissue blood flow rate by means of a photo transmitter and detector through fingertip known as photoplethysmography (PPG). The signal detected is firstly passed through active low pass filter and then amplified by a two stages high gain amplifier. The amplified signal is feed into the microcontroller to calculate the heart rate and displays the heart beat via sound systems and Liquid Crystal Display (LCD). To distinguish arrhythmia, normal heart rate and abnormal working conditions of the system, recognition is provided in different sounds, LCD readings and Light Emitting Diodes (LED).

  13. Lack of evidence for low-dimensional chaos in heart rate variability

    DEFF Research Database (Denmark)

    Kanters, J K; Holstein-Rathlou, N H; Agner, E

    1994-01-01

    INTRODUCTION: The term chaos is used to describe erratic or apparently random time-dependent behavior in deterministic systems. It has been suggested that the variability observed in the normal heart rate may be due to chaos, but this question has not been settled. METHODS AND RESULTS: Heart rate...... in the experimental data, but the prediction error as a function of the prediction length increased at a slower rate than characteristic of a low-dimensional chaotic system. CONCLUSION: There is no evidence for low-dimensional chaos in the time series of RR intervals from healthy human subjects. However, nonlinear...

  14. Visualization of heart rate variability of long-term heart transplant patient by transition networks: a case report

    Directory of Open Access Journals (Sweden)

    Joanna eWdowczyk

    2016-03-01

    Full Text Available We present a heart transplant patient at his 17th year of uncomplicated follow-up. Within a frame of routine check out several tests were performed. With such a long and uneventful follow-up some degree of graft reinnervation could be anticipated. However, the patient's electrocardiogram and exercise parameters seemed largely inconclusive in this regard. The exercise heart rate dynamics were suggestive of only mild, if any parasympathetic reinnervation of the graft with persisting sympathetic activation. On the other hand, traditional heart rate variability (HRV indices were inadequately high, due to erratic rhythm resulting from interference of the persisting recipient sinus node or nonconducted atrial parasystole. New tools, originated from network representation of time series, by visualization short-term dynamical patterns, provided a method to discern HRV increase due to reinnervation from other reasons.

  15. General anesthesia suppresses normal heart rate variability in humans

    Science.gov (United States)

    Matchett, Gerald; Wood, Philip

    2014-06-01

    The human heart normally exhibits robust beat-to-beat heart rate variability (HRV). The loss of this variability is associated with pathology, including disease states such as congestive heart failure (CHF). The effect of general anesthesia on intrinsic HRV is unknown. In this prospective, observational study we enrolled 100 human subjects having elective major surgical procedures under general anesthesia. We recorded continuous heart rate data via continuous electrocardiogram before, during, and after anesthesia, and we assessed HRV of the R-R intervals. We assessed HRV using several common metrics including Detrended Fluctuation Analysis (DFA), Multifractal Analysis, and Multiscale Entropy Analysis. Each of these analyses was done in each of the four clinical phases for each study subject over the course of 24 h: Before anesthesia, during anesthesia, early recovery, and late recovery. On average, we observed a loss of variability on the aforementioned metrics that appeared to correspond to the state of general anesthesia. Following the conclusion of anesthesia, most study subjects appeared to regain their normal HRV, although this did not occur immediately. The resumption of normal HRV was especially delayed on DFA. Qualitatively, the reduction in HRV under anesthesia appears similar to the reduction in HRV observed in CHF. These observations will need to be validated in future studies, and the broader clinical implications of these observations, if any, are unknown.

  16. Analyses of Heart Rate, Respiration and Cardiorespiratory Coupling in Patients with Schizophrenia

    Directory of Open Access Journals (Sweden)

    Steffen Schulz

    2015-01-01

    Full Text Available Schizophrenia is a severe mental disorder associated with a significantly increased cardiovascular mortality rate. However, the underlying mechanisms leading to this cardiovascular disease (CVD are not fully known. Therefore, the objective of this study was to characterize the cardiorespiratory influence by investigating heart rate, respiration and the causal strength and direction of cardiorespiratory coupling (CRC, based mainly on entropy measures. We investigated 23 non-medicated patients with schizophrenia (SZ, comparing them to 23 age- and gender-matched healthy controls (CO. A significantly reduced complexity was found for the heart rate and a significantly increased complexity in respiration and CRC in SZ patients when compared to corresponding measurements from CO (p < 0.001. CRC analyses revealed a clear coupling, with a driver-responder relationship from respiration to heart rate in SZ patients. Moreover, a slight driver-responder relationship from heart rate to respiration could be recognized. These findings lead to the assumption that SZ should be considered to be a high-risk group for CVD. We hypothesize that the varying cardiorespiratory regulation contributes to the increased risk for cardiac mortality. Therefore, regular monitoring of the cardiorespiratory status of SZ is suggested to identify autonomic regulation impairment at an early stage—to develop timely and effective treatment and intervention strategies.

  17. Nonlinear analysis of heart rate variability in patients with eating disorders

    NARCIS (Netherlands)

    Vigo, Daniel E.; Castro, Mariana N.; Dorpinghaus, Andrea; Weidema, Hylke; Cardinali, Daniel P.; Siri, Leonardo Nicola; Rovira, Bernardo; Fahrer, Rodolfo D.; Nogues, Martin; Leiguarda, Ramon C.; Guinjoan, Salvador M.

    2008-01-01

    Patients with anorexia nervosa or bulimia nervosa often have signs of autonomic dysfunction potentially deleterious to the heart. The aim of this study was to ascertain the nonlinear properties of heart rate variability in patients with eating disorders. A group of 33 women with eating disorders (14

  18. Evaluation of sympathetic nerve system activity with MIBG. Comparison with heart rate variability

    International Nuclear Information System (INIS)

    Kurata, Chinori; Wakabayashi, Yasushi; Shouda, Sakae; Mikami, Tadashi; Tawarahara, Kei; Sugiyama, Tsuyoshi; Nakano, Tomoyasu; Suzuki, Toshihiko.

    1997-01-01

    Authors attempted to elucidate the relations of plasma concentration of norepinephrine (pNE) and findings of heart rate variability and MIBG myocardial scintigraphy and evaluated cardiac autonomic nervous activity in chronic renal failure. Subjects were 211 patients with various heart diseases (coronary artery lesion, cardiomyopathy, hypertension, diabetes mellitus, renal failure and so on), 60 patients with artificial kidney due to chronic renal failure, 13 of whom were found to have coronary arterial disease by Tl myocardial scintigraphy, and 14 normal volunteers. ECG was recorded with the portable recorder for heart rate variability. Together with collection of blood for pNE measurement, myocardial scintigraphy was done at 15 and 150 min after intravenous administration of 111 MBq of MIBG for acquisition of early and delayed, respectively, images of the frontal breast. Accumulation at and elimination during the time points of MIBG were computed in cps unit. Variability of heart rate was found to have the correlation positive with MIBG delayed accumulation and negative with the elimination, and pNE, negative with heart rate variability and the delayed accumulation and positive with the elimination. Thus cardiac autonomic nervous abnormality was suggested to occur before uremic cardiomyopathy. (K.H.)

  19. Glutamate transporter type 3 knockout leads to decreased heart rate possibly via parasympathetic mechanism

    OpenAIRE

    Deng, Jiao; Li, Jiejie; Li, Liaoliao; Feng, Chenzhuo; Xiong, Lize; Zuo, Zhiyi

    2013-01-01

    Parasympathetic tone is a dominant neural regulator for basal heart rate. Glutamate transporters (EAAT) via their glutamate uptake functions regulate glutamate neurotransmission in the central nervous system. We showed that EAAT type 3 (EAAT3) knockout mice had a slower heart rate than wild-type mice when they were anesthetized. We design this study to determine whether non-anesthetized EAAT3 knockout mice have a slower heart rate and, if so, what may be the mechanism for this effect. Young a...

  20. [Wide QRS tachycardia preceded by pacemaker spikes].

    Science.gov (United States)

    Romero, M; Aranda, A; Gómez, F J; Jurado, A

    2014-04-01

    The differential diagnosis and therapeutic management of wide QRS tachycardia preceded by pacemaker spike is presented. The pacemaker-mediated tachycardia, tachycardia fibrillo-flutter in patients with pacemakers, and runaway pacemakers, have a similar surface electrocardiogram, but respond to different therapeutic measures. The tachycardia response to the application of a magnet over the pacemaker could help in the differential diagnosis, and in some cases will be therapeutic, as in the case of a tachycardia-mediated pacemaker. Although these conditions are diagnosed and treated in hospitals with catheterization laboratories using the application programmer over the pacemaker, patients presenting in primary care clinic and emergency forced us to make a diagnosis and treat the haemodynamically unstable patient prior to referral. Copyright © 2012 Sociedad Española de Médicos de Atención Primaria (SEMERGEN). Publicado por Elsevier España. All rights reserved.

  1. Heart Rate Changes in Electroacupuncture Treated Polycystic Ovary in Rats.

    Science.gov (United States)

    Ramadoss, Mukilan; Ramanathan, Gunasekaran; Subbiah, Angelie Jessica; Natrajan, Chidambaranathan

    2016-03-01

    Polycystic Ovary Syndrome (PCOS) is a common metabolic disorder, it affects both humans and animals. It may induce coronary heart disease, obesity and hyperandrogenism. Previous studies show that Low frequency Electroacupuncture (EA) have an effect on PCOS, however the exact pathway is unclear. To find the effect of EA on autonomic activity of the heart in Estradiol Valerate (EV) induced PCOS rats. Heart rate variability (HRV) was assessed in 3 groups: 1) Control; 2) PCOS rats; and 3) PCOS rats after EA treatment (n=8 in each group). From the time domain analysis and frequency domain analysis (linear measures) HRV analysis was done. EA stimulation was given at low frequency of 2Hz for 15 min on alternate days for 4-5 weeks. Collected data were statistically analysed using One-Way Analysis of Variance with the application of multiple comparisons of Tukey test. EA treatment group shows significant reduction in Heart Rate (HR) and low frequency, high frequency ratio (LF/HF); and increase in RR interval, Total Power (TP) when compared to PCOS group. The study concludes that EA treatment has a significant effect on reducing sympathetic tone and decreasing HR in PCOS.

  2. Heart Rate, Stress, and Occupational Noise Exposure among Electronic Waste Recycling Workers

    Directory of Open Access Journals (Sweden)

    Katrina N. Burns

    2016-01-01

    Full Text Available Electronic waste (e-waste is a growing occupational and environmental health issue around the globe. E-waste recycling is a green industry of emerging importance, especially in low-and middle-income countries where much of this recycling work is performed, and where many people’s livelihoods depend on this work. The occupational health hazards of e-waste recycling have not been adequately explored. We performed a cross-sectional study of noise exposures, heart rate, and perceived stress among e-waste recycling workers at a large e-waste site in Accra, Ghana. We interviewed 57 workers and continuously monitored their individual noise exposures and heart rates for up to 24 h. More than 40% of workers had noise exposures that exceeded recommended occupational (85 dBA and community (70 dBA noise exposure limits, and self-reported hearing difficulties were common. Workers also had moderate to high levels of perceived stress as measured via Cohen’s Perceived Stress Scale, and reported a variety of symptoms that could indicate cardiovascular disease. Noise exposures were moderately and significantly correlated with heart rate (Spearman’s ρ 0.46, p < 0.001. A mixed effects linear regression model indicated that a 1 dB increase in noise exposure was associated with a 0.17 increase in heart rate (p-value = 0.01 even after controlling for work activities, age, smoking, perceived stress, and unfavorable physical working conditions. These findings suggest that occupational and non-occupational noise exposure is associated with elevations in average heart rate, which may in turn predict potential cardiovascular damage.

  3. Combinatorial effect of nicotine and black tea on heart rate variability: Useful or harmful?

    Science.gov (United States)

    Joukar, S; Sheibani, M

    2017-06-01

    The effect of nicotine on heart rate variability (HRV) is controversial. Autonomic nervous system is the main regulator of heart rhythm, and heart rate variability is an appropriate index to assessment of the effects of the autonomic system on heart. In this study, the combination effect of nicotine and black tea consumption on sympatho-vagal balance and heart rate variability was investigated in rats. Male Wistar rats were randomized into four groups as control, tea (2.5 g/100 cc, daily), nicotine (2 mg/kg/d) and tea plus nicotine groups which treated for 28 days, and in the 29th day, their electrocardiograms (lead II) were recorded. The mean of high-frequency power (HF) in tea, nicotine and tea plus nicotine groups was significantly more than control group (P nicotine and tea + nicotine groups was significantly less than control group (P nicotine and tea + nicotine groups in comparison with control group (P nicotine or their combination with dosages used in this study can increase the heart rate variability and improve the sympatho-vagal balance in rat. © 2017 John Wiley & Sons Ltd.

  4. Effect of partial sports massage on blood pressure and heart rate

    Directory of Open Access Journals (Sweden)

    T.D. Pystupa

    2013-12-01

    Full Text Available With the growing popularity and demand for different types of massages (including sports is a growing need for research on specific forms. There is also a need to study the advantages and effects on various body functions. The objective was to study the effect of partial sports massage on blood pressure and heart rate in both men and women. Material and methods. Research has been extended 80 healthy men and women are physically active (age 20-25 years. Blood pressure and heart rate were made on the left arm automatic digital device (model HEM - 907. The device is intended to measure blood pressure. It is established that it is possible to verify the existing beliefs. This promotes more efficient use of massage therapy. Conclusions . Sports massage has an effect on hemodynamic changes, the increase (decrease in blood pressure acceleration (deceleration of the heart rate. It depends on what part of the body exposed to the massage procedure.

  5. GLP-1 receptor stimulation depresses heart rate variability and inhibits neurotransmission to cardiac vagal neurons.

    Science.gov (United States)

    Griffioen, Kathleen J; Wan, Ruiqian; Okun, Eitan; Wang, Xin; Lovett-Barr, Mary Rachael; Li, Yazhou; Mughal, Mohamed R; Mendelowitz, David; Mattson, Mark P

    2011-01-01

    glucagon-like peptide 1 (GLP-1) is an incretin hormone released from the gut in response to food intake. Whereas GLP-1 acts in the periphery to inhibit glucagon secretion and stimulate insulin release, it also acts in the central nervous system to mediate autonomic control of feeding, body temperature, and cardiovascular function. Because of its role as an incretin hormone, GLP-1 receptor analogs are used as a treatment for type 2 diabetes. Central or peripheral administration of GLP-1 increases blood pressure and heart rate, possibly by activating brainstem autonomic nuclei and increasing vagus nerve activity. However, the mechanism(s) by which GLP-1 receptor stimulation affects cardiovascular function are unknown. We used the long-lasting GLP-1 receptor agonist Exendin-4 (Ex-4) to test the hypothesis that GLP-1 signalling modulates central parasympathetic control of heart rate. using a telemetry system, we assessed heart rate in mice during central Ex-4 administration. Heart rate was increased by both acute and chronic central Ex-4 administration. Spectral analysis indicated that the high frequency and low frequency powers of heart rate variability were diminished by Ex-4 treatment. Finally, Ex-4 decreased both excitatory glutamatergic and inhibitory glycinergic neurotransmission to preganglionic parasympathetic cardiac vagal neurons. these data suggest that central GLP-1 receptor stimulation diminishes parasympathetic modulation of the heart thereby increasing heart rate.

  6. Heart rate turbulence as a marker of myocardial electrical instability in children with hypertrophic cardiomyopathy

    Directory of Open Access Journals (Sweden)

    V. A. Makarova

    2014-01-01

    Full Text Available Heart rate turbulence is a myocardial electrical instability marker used to stratify the risk of sudden cardiac death. Fifty children aged 7 to 17 years with hypertrophic cardiomyopathy were examined. The survey program included standard electrocardiography, Doppler echocardiography, and 24-hour Holter ECG monitoring. Heart rate turbulence parameters, such as turbulence onset and turbulence slope, were analyzed. According to turbulence onset greater than zero, heart rate turbulence impairment was identified in 5 of the 24 patients included in the survey. The abnormal turbulence slope values of less than 6 msec/RR were found in 3 patients. Both parameters were abnormal in 1 patient. Heart rate turbulence impairment was significantly more common in children with the non-obstructive form of hypertrophic cardiomyopathy than in those with its obstructive form (χ2=3,05; p=0,08. All the children with abnormal heart rhythm turbulence values had one or more major risk factors for sudden cardiac death, which significantly exceeds their rates in the normal heart rate turbulence groups (χ2=7,11; p=0,007. The patients with abnormal turbulence onset values were more often found to have syncope (χ2=3,2; p=0,02. One such patient was recorded to have unstable ventricular tachycardia (χ2=10,56; p=0,001. Our findings suggest that heart rate turbulence is an additional predictor of the unfavorable course of hypertrophic cardiomyopathy in children. 

  7. Heart rate modulation in stable coronary artery disease without clinical heart failure: What we have already learned from SIGNIFY?

    Directory of Open Access Journals (Sweden)

    Gian Piero Perna

    2016-12-01

    In conclusion, heart rate is a marker of risk but is not a risk factor and/or a target of therapy in patients with stable coronary artery disease and preserved ventricular systolic function. Standard doses of ivabradine are indicated for treatment of angina as an alternative or in addition to beta-blockers, but should not be administered in association with CYP3A4 inhibitors or heart rate-lowering calcium-channel blockers.

  8. High readmission rate after heart valve surgery

    DEFF Research Database (Denmark)

    Sibilitz, K L; Berg, S K; Thygesen, L C

    2015-01-01

    investigated. RESULTS: After valve surgery, the self-reported health was lower (Short Form-36 (SF-36) Physical Component Scale (PCS): 44.5 vs. 50.6 and Mental Component Scale (MCS): 51.9 vs. 55.0, pClinical signs......BACKGROUND: After heart valve surgery, knowledge on long-term self-reported health status and readmission is lacking. Thus, the optimal strategy for out-patient management after surgery remains unclear. METHODS: Using a nationwide survey with linkage to Danish registers with one year follow-up, we...... included all adults 6-12months after heart valve surgery irrespective of valve procedure, during Jan-June 2011 (n=867). Participants completed a questionnaire regarding health-status (n=742), and answers were compared with age- and sex-matched healthy controls. Readmission rates and mortality were...

  9. Simplifying cardiovascular risk estimation using resting heart rate.

    LENUS (Irish Health Repository)

    Cooney, Marie Therese

    2010-09-01

    Elevated resting heart rate (RHR) is a known, independent cardiovascular (CV) risk factor, but is not included in risk estimation systems, including Systematic COronary Risk Evaluation (SCORE). We aimed to derive risk estimation systems including RHR as an extra variable and assess the value of this addition.

  10. Smartphone-based photoplethysmographic imaging for heart rate monitoring.

    Science.gov (United States)

    Alafeef, Maha

    2017-07-01

    The purpose of this study is to make use of visible light reflected mode photoplethysmographic (PPG) imaging for heart rate (HR) monitoring via smartphones. The system uses the built-in camera feature in mobile phones to capture video from the subject's index fingertip. The video is processed, and then the PPG signal resulting from the video stream processing is used to calculate the subject's heart rate. Records from 19 subjects were used to evaluate the system's performance. The HR values obtained by the proposed method were compared with the actual HR. The obtained results show an accuracy of 99.7% and a maximum absolute error of 0.4 beats/min where most of the absolute errors lay in the range of 0.04-0.3 beats/min. Given the encouraging results, this type of HR measurement can be adopted with great benefit, especially in the conditions of personal use or home-based care. The proposed method represents an efficient portable solution for HR accurate detection and recording.

  11. SVM-Based Spectral Analysis for Heart Rate from Multi-Channel WPPG Sensor Signals.

    Science.gov (United States)

    Xiong, Jiping; Cai, Lisang; Wang, Fei; He, Xiaowei

    2017-03-03

    Although wrist-type photoplethysmographic (hereafter referred to as WPPG) sensor signals can measure heart rate quite conveniently, the subjects' hand movements can cause strong motion artifacts, and then the motion artifacts will heavily contaminate WPPG signals. Hence, it is challenging for us to accurately estimate heart rate from WPPG signals during intense physical activities. The WWPG method has attracted more attention thanks to the popularity of wrist-worn wearable devices. In this paper, a mixed approach called Mix-SVM is proposed, it can use multi-channel WPPG sensor signals and simultaneous acceleration signals to measurement heart rate. Firstly, we combine the principle component analysis and adaptive filter to remove a part of the motion artifacts. Due to the strong relativity between motion artifacts and acceleration signals, the further denoising problem is regarded as a sparse signals reconstruction problem. Then, we use a spectrum subtraction method to eliminate motion artifacts effectively. Finally, the spectral peak corresponding to heart rate is sought by an SVM-based spectral analysis method. Through the public PPG database in the 2015 IEEE Signal Processing Cup, we acquire the experimental results, i.e., the average absolute error was 1.01 beat per minute, and the Pearson correlation was 0.9972. These results also confirm that the proposed Mix-SVM approach has potential for multi-channel WPPG-based heart rate estimation in the presence of intense physical exercise.

  12. The Use of Heart Rate Monitors in Physical Education

    Science.gov (United States)

    Nichols, Randall; Davis, Kathryn L.; McCord, Tim; Schmidt, Dave; Slezak, Alex M.

    2009-01-01

    The ever-rising rate of obesity and the need for increased physical activity for young children is well documented. Data suggests that today's youth are not participating in enough quality health-enhancing physical activity either in or outside of school. Heart rate monitors have been used by adult exercisers for many years to monitor and assess…

  13. Thermal effect on heart rate and hemodynamics in vitelline arteries of stage 18 chicken embryos.

    Science.gov (United States)

    Lee, Jung Yeop; Lee, Sang Joon

    2010-12-01

    We investigated the thermal effects on heart rate, hemodynamics, and response of vitelline arteries of stage-18 chicken embryos. Heart rate was monitored by a high-speed imaging method, while hemodynamic quantities were evaluated using a particle image velocimetry (PIV) technique. Experiments were carried out at seven different temperatures (36-42 °C with 1 °C interval) after 1h of incubation to stabilize the heart rate. The heart rate increased in a linear manner (r = 0.992). Due to the increased cardiac output (or heart rate), the hemodynamic quantities such as mean velocity (U(mean)), velocity fluctuation (U(fluc)), and peak velocity (U(peak)) also increased with respect to the Womersley number (Ω) in the manner r = 0.599, 0.693, and 0.725, respectively. This indicates that the mechanical force exerting on the vessel walls increases. However, the active response (or regulation) of the vitelline arteries was not observed in this study. Copyright © 2010 Elsevier Ltd. All rights reserved.

  14. Correlation of radiation dose and heart rate in dual-source computed tomography coronary angiography.

    Science.gov (United States)

    Laspas, Fotios; Tsantioti, Dimitra; Roussakis, Arkadios; Kritikos, Nikolaos; Efthimiadou, Roxani; Kehagias, Dimitrios; Andreou, John

    2011-04-01

    Computed tomography coronary angiography (CTCA) has been widely used since the introduction of 64-slice scanners and dual-source CT technology, but the relatively high radiation dose remains a major concern. To evaluate the relationship between radiation exposure and heart rate (HR), in dual-source CTCA. Data from 218 CTCA examinations, performed with a dual-source 64-slices scanner, were statistically evaluated. Effective radiation dose, expressed in mSv, was calculated as the product of the dose-length product (DLP) times a conversion coefficient for the chest (mSv = DLPx0.017). Heart rate range and mean heart rate, expressed in beats per minute (bpm) of each individual during CTCA, were also provided by the system. Statistical analysis of effective dose and heart rate data was performed by using Pearson correlation coefficient and two-sample t-test. Mean HR and effective dose were found to have a borderline positive relationship. Individuals with a mean HR >65 bpm observed to receive a statistically significant higher effective dose as compared to those with a mean HR ≤65 bpm. Moreover, a strong correlation between effective dose and variability of HR of more than 20 bpm was observed. Dual-source CT scanners are considered to have the capability to provide diagnostic examinations even with high HR and arrhythmias. However, it is desirable to keep the mean heart rate below 65 bpm and heart rate fluctuation less than 20 bpm in order to reduce the radiation exposure.

  15. HEART RATE VARIABILITY CLASSIFICATION USING SADE-ELM CLASSIFIER WITH BAT FEATURE SELECTION

    Directory of Open Access Journals (Sweden)

    R Kavitha

    2017-07-01

    Full Text Available The electrical activity of the human heart is measured by the vital bio medical signal called ECG. This electrocardiogram is employed as a crucial source to gather the diagnostic information of a patient’s cardiopathy. The monitoring function of cardiac disease is diagnosed by documenting and handling the electrocardiogram (ECG impulses. In the recent years many research has been done and developing an enhanced method to identify the risk in the patient’s body condition by processing and analysing the ECG signal. This analysis of the signal helps to find the cardiac abnormalities, arrhythmias, and many other heart problems. ECG signal is processed to detect the variability in heart rhythm; heart rate variability is calculated based on the time interval between heart beats. Heart Rate Variability HRV is measured by the variation in the beat to beat interval. The Heart rate Variability (HRV is an essential aspect to diagnose the properties of the heart. Recent development enhances the potential with the aid of non-linear metrics in reference point with feature selection. In this paper, the fundamental elements are taken from the ECG signal for feature selection process where Bat algorithm is employed for feature selection to predict the best feature and presented to the classifier for accurate classification. The popular machine learning algorithm ELM is taken for classification, integrated with evolutionary algorithm named Self- Adaptive Differential Evolution Extreme Learning Machine SADEELM to improve the reliability of classification. It combines Effective Fuzzy Kohonen clustering network (EFKCN to be able to increase the accuracy of the effect for HRV transmission classification. Hence, it is observed that the experiment carried out unveils that the precision is improved by the SADE-ELM method and concurrently optimizes the computation time.

  16. Dogs with macroadenomas have lower body temperature and heart rate than dogs with microadenomas.

    Science.gov (United States)

    Benchekroun, Ghita; Desquilbet, Loic; Herrtage, Michael E; Jeffery, Nick D; Rosenberg, Dan; Granger, Nicolas

    2017-09-01

    Pituitary macroadenomas compress the hypothalamus, which partly regulates heart rate and body temperature. The aim of this study was to investigate whether heart rate and/or body temperature could aid in clinically differentiating dogs with macroadenomas from dogs with microadenomas (i.e. small non-compressive pituitary mass). Two groups of dogs diagnosed with pituitary-dependent hyperadrenocorticism (i.e. Cushing's disease) were included. Heart rate and body temperature were collected on initial presentation before any procedure. Dogs with macroadenoma had a significantly lower heart rate and body temperature (Pdogs with microadenoma. We suggest that the combined cut-off values of 84 beats per minutes and 38.3°C in dogs with Cushing's disease, especially with vague neurological signs (nine of 12 dogs=75%), might help to suspect the presence of a macroadenoma. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Heart rate turbulence after ventricular premature beats in healthy Doberman pinschers and those with dilated cardiomyopathy.

    Science.gov (United States)

    Harris, J D; Little, C J L; Dennis, J M; Patteson, M W

    2017-10-01

    To describe the measurement of heart rate turbulence (HRT) after ventricular premature beats and compare HRT in healthy Doberman pinschers and those with dilated cardiomyopathy (DCM), with and without congestive heart failure (CHF). Sixty-five client-owned Dobermans: 20 healthy (NORMAL), 31 with preclinical DCM and 14 with DCM and CHF (DCM + CHF). A retrospective study of data retrieved from clinical records and ambulatory ECG (Holter) archives, including data collected previously for a large-scale prospective study of Dobermans with preclinical DCM. Holter data were reanalysed quantitatively, including conventional time-domain heart rate variability and the HRT parameters turbulence onset and turbulence slope. Heart rate turbulence could be measured in 58/65 dogs. Six Holter recordings had inadequate ventricular premature contractions (VPCs) and one exhibited VPCs too similar to sinus morphology. Heart rate turbulence parameter, turbulence onset, was significantly reduced in DCM dogs, whereas conventional heart rate variability measures were not. Heart rate variability and HRT markers were reduced in DCM + CHF dogs as expected. Heart rate turbulence can be measured from the majority of good quality standard canine 24-hour Holter recordings with >5 VPCs. Turbulence onset is significantly reduced in Dobermans with preclinical DCM which indicates vagal withdrawal early in the course of disease. Heart rate turbulence is a powerful prognostic indicator in human cardiac disease which can be measured from standard 24-hour ambulatory ECG (Holter) recordings using appropriate computer software. Further studies are warranted to assess whether HRT may be of prognostic value in dogs with preclinical DCM and in other canine cardiac disease. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Noninvasive Diagnosis of Coronary Artery Disease Using 12-Lead High-Frequency Electrocardiograms

    Science.gov (United States)

    Schlegel, Todd T.; Arenare, Brian

    2006-01-01

    A noninvasive, sensitive method of diagnosing certain pathological conditions of the human heart involves computational processing of digitized electrocardiographic (ECG) signals acquired from a patient at all 12 conventional ECG electrode positions. In the processing, attention is focused on low-amplitude, high-frequency components of those portions of the ECG signals known in the art as QRS complexes. The unique contribution of this method lies in the utilization of signal features and combinations of signal features from various combinations of electrode positions, not reported previously, that have been found to be helpful in diagnosing coronary artery disease and such related pathological conditions as myocardial ischemia, myocardial infarction, and congestive heart failure. The electronic hardware and software used to acquire the QRS complexes and perform some preliminary analyses of their high-frequency components were summarized in Real-Time, High-Frequency QRS Electrocardiograph (MSC- 23154), NASA Tech Briefs, Vol. 27, No. 7 (July 2003), pp. 26-28. To recapitulate, signals from standard electrocardiograph electrodes are preamplified, then digitized at a sampling rate of 1,000 Hz, then analyzed by the software that detects R waves and QRS complexes and analyzes them from several perspectives. The software includes provisions for averaging signals over multiple beats and for special-purpose nonrecursive digital filters with specific low- and high-frequency cutoffs. These filters, applied to the averaged signal, effect a band-pass operation in the frequency range from 150 to 250 Hz. The output of the bandpass filter is the desired high-frequency QRS signal. Further processing is then performed in real time to obtain the beat-to-beat root mean square (RMS) voltage amplitude of the filtered signal, certain variations of the RMS voltage, and such standard measures as the heart rate and R-R interval at any given time. A key signal feature analyzed in the present

  19. Impact of space weather on human heart rate during the years 2011-2013

    Science.gov (United States)

    Galata, E.; Ioannidou, S.; Papailiou, M.; Mavromichalaki, H.; Paravolidakis, K.; Kouremeti, M.; Rentifis, L.; Simantirakis, E.; Trachanas, K.

    2017-08-01

    During the last years a possible link between different levels of solar and geomagnetic disturbances and human physiological parameters is suggested by several published studies. In this work the examination of the potential association between heart rate variations and specific space weather activities was performed. A total of 482 individuals treated at Hippocratio General Hospital in Athens, the Cardiology clinics of Nikaia General Hospital in Piraeus and the Heraklion University Hospital in Crete, Greece, were assessed from July 2011 to April 2013. The heart rate of the individuals was recorded by a Holter monitor on a n hourly basis, while the hourly variations of the cosmic ray intensity measured by the Neutron Monitor Station of the Athens University and of the geomagnetic index Dst provided by the Kyoto Observatory were used. The ANalysis Of VAriance (ANOVA) and the Multiple Linear Regression analysis were used for analysis of these data. A statistically significant effect of both cosmic rays and geomagnetic activity on heart rate was observed, which may indicate that changes in space weather could be linked to heart rate variations.

  20. Development of an Algorithm for Heart Rate Measurement Using a Mobile Phone Camera

    Directory of Open Access Journals (Sweden)

    D. A. Laure

    2014-01-01

    Full Text Available Nowadays there exist many different ways to measure a person’s heart rate. One of them assumes the usage of a mobile phone built-in camera. This method is easy to use and does not require any additional skills or special devices for heart rate measurement. It requires only a mobile cellphone with a built-in camera and a flash. The main idea of the method is to detect changes in finger skin color that occur due to blood pulsation. The measurement process is simple: the user covers the camera lens with a finger and the application on the mobile phone starts catching and analyzing frames from the camera. Heart rate can be calculated by analyzing average red component values of frames taken by the mobile cellphone camera that contain images of an area of the skin.In this paper the authors review the existing algorithms for heart rate measurement with the help of a mobile phone camera and propose their own algorithm which is more efficient than the reviewed algorithms.

  1. Heart rate, heart rate variability, and arrhythmias in dogs with myxomatous mitral valve disease

    DEFF Research Database (Denmark)

    Rasmussen, Caroline Elisabeth; Falk, Bo Torkel; Zois, Nora Elisabeth

    2012-01-01

    Autonomic modulation of heart rhythm is thought to influence the pathophysiology of myxomatous mitral valve disease (MMVD).......Autonomic modulation of heart rhythm is thought to influence the pathophysiology of myxomatous mitral valve disease (MMVD)....

  2. Neonatal heart rate prediction.

    Science.gov (United States)

    Abdel-Rahman, Yumna; Jeremic, Aleksander; Tan, Kenneth

    2009-01-01

    Technological advances have caused a decrease in the number of infant deaths. Pre-term infants now have a substantially increased chance of survival. One of the mechanisms that is vital to saving the lives of these infants is continuous monitoring and early diagnosis. With continuous monitoring huge amounts of data are collected with so much information embedded in them. By using statistical analysis this information can be extracted and used to aid diagnosis and to understand development. In this study we have a large dataset containing over 180 pre-term infants whose heart rates were recorded over the length of their stay in the Neonatal Intensive Care Unit (NICU). We test two types of models, empirical bayesian and autoregressive moving average. We then attempt to predict future values. The autoregressive moving average model showed better results but required more computation.

  3. Making the Most of the "Daphnia" Heart Rate Lab: Optimizing the Use of Ethanol, Nicotine & Caffeine

    Science.gov (United States)

    Corotto, Frank; Ceballos, Darrel; Lee, Adam; Vinson, Lindsey

    2010-01-01

    Students commonly test the effects of chemical agents on the heart rate of the crustacean "Daphnia" magna, but the procedure has never been optimized. We determined the effects of three concentrations of ethanol, nicotine, and caffeine and of a control solution on heart rate in "Daphnia." Ethanol at 5% and 10% (v/v) reduced mean heart rate to…

  4. Co-administration of Apelin and T4 Protects Inotropic and Chronotropic Changes Occurring in Hypothyroid Rats

    Energy Technology Data Exchange (ETDEWEB)

    Akhondali, Zahra; Badavi, Mohammad; Dianat, Mahin, E-mail: dianat@ajums.ac.ir; Faraji, Farzaneh [Physiology Research Center and Department of Physiology, Faculty of Medicine, Ahvaz Jundishapur University of Medical Sciences, Ahvaz (Iran, Islamic Republic of)

    2015-09-15

    One of the most important thyroid hormone targets is the cardiovascular system. Hemodynamic changes, such as decreased resting heart rate (HR), myocardial contractility, and cardiac output, and increased diastolic pressure and systemic vascular resistance, have been observed in hypothyroid patients. Moreover, in these patients, ECG changes include sinus bradycardia and low voltage complexes (P waves or QRS complexes). This study aimed at evaluating the prophylactic effect of apelin on HR changes and QRS voltage that occur in propylthiouracil (PTU)-induced hypothyroid rats. In this study, 48 adult male Wistar rats weighing 170-235g were randomly divided into 6 groups: Control group (normal saline ip injection + tap water gavage); P group (PTU 0.05%, in drinking water); A group (apelin 200 µg.kg{sup -1}.day{sup -1}, ip); PA group [co-administration of PTU and apelin]; PT group [co-administration of PTU + T4 (0.2 mg/g per day, gavage)]; and PAT group (co-administration of PTU, apelin and T4). All experiments were performed for 28 consecutive days, and then the animals were anesthetized with an ip injection of ketamine (80 mg/kg) and xylazine (12 mg/kg). Lead II electrocardiogram was recorded to calculate HR and QRS voltage. Heart rate and QRS voltage increased more significantly in the hypothyroid group that consumed both apelin and T4 (201 ± 4 beat/min, 0.71 ± 0.02 mv vs. hypothyroid 145 ± 9 beat/min, 0.563 ± 0.015 mv; respectively). The co-administration of apelin and T4 showed a protective effect on QRS voltage and HR in PTU‑induced hypothyroid rats.

  5. Co-administration of Apelin and T4 Protects Inotropic and Chronotropic Changes Occurring in Hypothyroid Rats

    Directory of Open Access Journals (Sweden)

    Zahra Akhondali

    2015-01-01

    Full Text Available Abstract Background: One of the most important thyroid hormone targets is the cardiovascular system. Hemodynamic changes, such as decreased resting heart rate (HR, myocardial contractility, and cardiac output, and increased diastolic pressure and systemic vascular resistance, have been observed in hypothyroid patients. Moreover, in these patients, ECG changes include sinus bradycardia and low voltage complexes (P waves or QRS complexes. Objective: This study aimed at evaluating the prophylactic effect of apelin on HR changes and QRS voltage that occur in propylthiouracil (PTU-induced hypothyroid rats. Method: In this study, 48 adult male Wistar rats weighing 170-235g were randomly divided into 6 groups: Control group (normal saline ip injection + tap water gavage; P group (PTU 0.05%, in drinking water; A group (apelin 200 µg.kg-1.day-1, ip; PA group [co-administration of PTU and apelin]; PT group [co-administration of PTU + T4 (0.2 mg/g per day, gavage]; and PAT group (co-administration of PTU, apelin and T4. All experiments were performed for 28 consecutive days, and then the animals were anesthetized with an ip injection of ketamine (80 mg/kg and xylazine (12 mg/kg. Lead II electrocardiogram was recorded to calculate HR and QRS voltage. Results: Heart rate and QRS voltage increased more significantly in the hypothyroid group that consumed both apelin and T4 (201 ± 4 beat/min, 0.71 ± 0.02 mv vs. hypothyroid 145 ± 9 beat/min, 0.563 ± 0.015 mv; respectively. Conclusion: The co-administration of apelin and T4 showed a protective effect on QRS voltage and HR in PTU‑induced hypothyroid rats.

  6. Heart Rate, Stress, and Occupational Noise Exposure among Electronic Waste Recycling Workers.

    Science.gov (United States)

    Burns, Katrina N; Sun, Kan; Fobil, Julius N; Neitzel, Richard L

    2016-01-19

    Electronic waste (e-waste) is a growing occupational and environmental health issue around the globe. E-waste recycling is a green industry of emerging importance, especially in low-and middle-income countries where much of this recycling work is performed, and where many people's livelihoods depend on this work. The occupational health hazards of e-waste recycling have not been adequately explored. We performed a cross-sectional study of noise exposures, heart rate, and perceived stress among e-waste recycling workers at a large e-waste site in Accra, Ghana. We interviewed 57 workers and continuously monitored their individual noise exposures and heart rates for up to 24 h. More than 40% of workers had noise exposures that exceeded recommended occupational (85 dBA) and community (70 dBA) noise exposure limits, and self-reported hearing difficulties were common. Workers also had moderate to high levels of perceived stress as measured via Cohen's Perceived Stress Scale, and reported a variety of symptoms that could indicate cardiovascular disease. Noise exposures were moderately and significantly correlated with heart rate (Spearman's ρ 0.46, p stress, and unfavorable physical working conditions. These findings suggest that occupational and non-occupational noise exposure is associated with elevations in average heart rate, which may in turn predict potential cardiovascular damage.

  7. Heart rate response to a climber’s fall in sport climbing

    OpenAIRE

    Chaloupsky, David

    2015-01-01

    The research deals with response of heart rate to a climber’s simulated fall in a leading position when indoor climbing. Heart rate of climbers was recorded during ascents of an overhanging route in the leading position, to the given point high above the ground, followed by falling into the last protection. The length of the free fall was defined by the place of the last belay anchor, which was at the height of climber’s ankles. The length of the fall was about two meters of free fall plus th...

  8. Attenuated heart rate response in REM sleep behavior disorder and Parkinson's disease

    DEFF Research Database (Denmark)

    Sorensen, Gertrud Laura; Kempfner, Jacob; Zoetmulder, Marielle

    2012-01-01

    The objective of this study was to determine whether patients with Parkinson's disease with and without rapid‐eye‐movement sleep behavior disorder and patients with idiopathic rapid‐eye‐movement sleep behavior disorder have an attenuated heart rate response to arousals or to leg movements during...... sleep compared with healthy controls. Fourteen and 16 Parkinson's patients with and without rapid‐eye‐movement sleep behavior disorder, respectively, 11 idiopathic rapid‐eye‐movement sleep behavior disorder patients, and 17 control subjects underwent 1 night of polysomnography. The heart rate response...... associated with arousal or leg movement from all sleep stages was analyzed from 10 heartbeats before the onset of the sleep event to 15 heartbeats following onset of the sleep event. The heart rate reponse to arousals was significantly lower in both parkinsonian groups compared with the control group...

  9. Heart-Rate Variability—More than Heart Beats?

    Directory of Open Access Journals (Sweden)

    Gernot Ernst

    2017-09-01

    Full Text Available Heart-rate variability (HRV is frequently introduced as mirroring imbalances within the autonomous nerve system. Many investigations are based on the paradigm that increased sympathetic tone is associated with decreased parasympathetic tone and vice versa. But HRV is probably more than an indicator for probable disturbances in the autonomous system. Some perturbations trigger not reciprocal, but parallel changes of vagal and sympathetic nerve activity. HRV has also been considered as a surrogate parameter of the complex interaction between brain and cardiovascular system. Systems biology is an inter-disciplinary field of study focusing on complex interactions within biological systems like the cardiovascular system, with the help of computational models and time series analysis, beyond others. Time series are considered surrogates of the particular system, reflecting robustness or fragility. Increased variability is usually seen as associated with a good health condition, whereas lowered variability might signify pathological changes. This might explain why lower HRV parameters were related to decreased life expectancy in several studies. Newer integrating theories have been proposed. According to them, HRV reflects as much the state of the heart as the state of the brain. The polyvagal theory suggests that the physiological state dictates the range of behavior and psychological experience. Stressful events perpetuate the rhythms of autonomic states, and subsequently, behaviors. Reduced variability will according to this theory not only be a surrogate but represent a fundamental homeostasis mechanism in a pathological state. The neurovisceral integration model proposes that cardiac vagal tone, described in HRV beyond others as HF-index, can mirror the functional balance of the neural networks implicated in emotion–cognition interactions. Both recent models represent a more holistic approach to understanding the significance of HRV.

  10. Heart-Rate Variability-More than Heart Beats?

    Science.gov (United States)

    Ernst, Gernot

    2017-01-01

    Heart-rate variability (HRV) is frequently introduced as mirroring imbalances within the autonomous nerve system. Many investigations are based on the paradigm that increased sympathetic tone is associated with decreased parasympathetic tone and vice versa . But HRV is probably more than an indicator for probable disturbances in the autonomous system. Some perturbations trigger not reciprocal, but parallel changes of vagal and sympathetic nerve activity. HRV has also been considered as a surrogate parameter of the complex interaction between brain and cardiovascular system. Systems biology is an inter-disciplinary field of study focusing on complex interactions within biological systems like the cardiovascular system, with the help of computational models and time series analysis, beyond others. Time series are considered surrogates of the particular system, reflecting robustness or fragility. Increased variability is usually seen as associated with a good health condition, whereas lowered variability might signify pathological changes. This might explain why lower HRV parameters were related to decreased life expectancy in several studies. Newer integrating theories have been proposed. According to them, HRV reflects as much the state of the heart as the state of the brain. The polyvagal theory suggests that the physiological state dictates the range of behavior and psychological experience. Stressful events perpetuate the rhythms of autonomic states, and subsequently, behaviors. Reduced variability will according to this theory not only be a surrogate but represent a fundamental homeostasis mechanism in a pathological state. The neurovisceral integration model proposes that cardiac vagal tone, described in HRV beyond others as HF-index, can mirror the functional balance of the neural networks implicated in emotion-cognition interactions. Both recent models represent a more holistic approach to understanding the significance of HRV.

  11. Effects of slow breathing rate on heart rate variability and arterial baroreflex sensitivity in essential hypertension.

    Science.gov (United States)

    Li, Changjun; Chang, Qinghua; Zhang, Jia; Chai, Wenshu

    2018-05-01

    This study is to investigate the effects of slow breathing on heart rate variability (HRV) and arterial baroreflex sensitivity in essential hypertension.We studied 60 patients with essential hypertension and 60 healthy controls. All subjects underwent controlled breathing at 8 and 16 breaths per minute. Electrocardiogram, respiratory, and blood pressure signals were recorded simultaneously. We studied effects of slow breathing on heart rate, blood pressure and respiratory peak, high-frequency (HF) power, low-frequency (LF) power, and LF/HF ratio of HRV with traditional and corrected spectral analysis. Besides, we tested whether slow breathing was capable of modifying baroreflex sensitivity in hypertensive subjects.Slow breathing, compared with 16 breaths per minute, decreased the heart rate and blood pressure (all P hypertensive subjects. Slow breathing increased baroreflex sensitivity in hypertensive subjects (from 59.48 ± 6.39 to 78.93 ± 5.04 ms/mm Hg, P hypertension. Besides, slow breathing increased baroreflex sensitivity in hypertensive subjects. These demonstrate slow breathing is indeed capable of shifting sympatho-vagal balance toward vagal activities and increasing baroreflex sensitivity, suggesting a safe, therapeutic approach for essential hypertension.

  12. Study of foetal heart rate patterns in pregnancy with intra-uterine growth restriction during antepartum period

    International Nuclear Information System (INIS)

    Fardiazar, Z.; Abassalizade, F.

    2013-01-01

    Objectives: To evaluate foetal heart rate pattern during antepartum period in pregnancies suffering from intra-uterine growth restriction. Methods: The case control study was conducted at the Alzahra Hospital, Tabriz, Iran from April 2008 to April 2011. It comprised 100 pregnancies with intra-uterine growth restriction and 92 normal pregnancies. The foetal heart rate pattern including basal heart rate, beat-to-beat variation, non-stress test (NST) result and acceleration and deceleration patterns of the heart rate were determined in both groups during the antepartum period. Findings were compared between the two groups and their relation with pregnancy-foetal outcomes was specified in the case group. SPSS 15 was used for statistical analysis. Results: There was no statistically significant difference between the foetus mean basal heart rate in the two groups (p <0.960). Frequency of cases with non-reactive non-stress test in the Cases was significantly higher than Controls (p <0.005). The difference in heart rate acceleration was also not statistically significant (p <0.618). Frequency of cases with low birth weight and caesarian was non-significantly but borderline higher among the Cases (p <0.081 and 0.060, respectively). Conclusion: Abnormal foetal heart rate pattern is more common in pregnancies marked by intra-uterine growth restriction and is directly associated with worse pregnancy/foetal outcomes. (author)

  13. Heart Rate Variability Is Associated with Exercise Capacity in Patients with Cardiac Syndrome X.

    Directory of Open Access Journals (Sweden)

    Dai-Yin Lu

    Full Text Available Heart rate variability (HRV reflects the healthiness of autonomic nervous system, which is associated with exercise capacity. We therefore investigated whether HRV could predict the exercise capacity in the adults with cardiac syndrome X (CSX. A total of 238 subjects (57±12 years, 67.8% men, who were diagnosed as CSX by the positive exercise stress test and nearly normal coronary angiogram were enrolled. Power spectrum from the 24-hour recording of heart rate was analyzed in frequency domain using total power (TP and spectral components of the very low frequency (VLF, low frequency (LF and high frequency (HF ranges. Among the study population, 129 subjects with impaired exercise capacity during the treadmill test had significantly lower HRV indices than those with preserved exercise capacity (≥90% of the age predicted maximal heart rate. After accounting for age, sex, and baseline SBP and heart rate, VLF (odds ratio per 1SD and 95% CI: 2.02, 1.19-3.42, LF (1.67, 1.10-2.55, and TP (1.82, 1.17-2.83 remained significantly associated with preserved exercise capacity. In addition, increased HRV indices were also associated with increased exercise duration, rate-pressure product, and heart rate recovery, independent of age, body mass index, and baseline SBP and heart rate. In subgroup analysis, HRV indices demonstrated similar predictive values related to exercise capacity across various subpopulations, especially in the young. In patients with CSX, HRV was independently associated with exercise capacity, especially in young subjects. The healthiness of autonomic nervous system may have a role in modulating the exercise capacity in patients with CSX.

  14. Correlation of radiation dose and heart rate in dual-source computed tomography coronary angiography

    International Nuclear Information System (INIS)

    Laspas, Fotios; Roussakis, Arkadios; Kritikos, Nikolaos; Efthimiadou, Roxani; Kehagias, Dimitrios; Andreou, John; Tsantioti, Dimitra

    2011-01-01

    Background: Computed tomography coronary angiography (CTCA) has been widely used since the introduction of 64-slice scanners and dual-source CT technology, but the relatively high radiation dose remains a major concern. Purpose: To evaluate the relationship between radiation exposure and heart rate (HR), in dual-source CTCA. Material and Methods: Data from 218 CTCA examinations, performed with a dual-source 64-slices scanner, were statistically evaluated. Effective radiation dose, expressed in mSv, was calculated as the product of the dose-length product (DLP) times a conversion coefficient for the chest (mSv = DLPx0.017). Heart rate range and mean heart rate, expressed in beats per minute (bpm) of each individual during CTCA, were also provided by the system. Statistical analysis of effective dose and heart rate data was performed by using Pearson correlation coefficient and two-sample t-test. Results: Mean HR and effective dose were found to have a borderline positive relationship. Individuals with a mean HR >65 bpm observed to receive a statistically significant higher effective dose as compared to those with a mean HR =65 bpm. Moreover, a strong correlation between effective dose and variability of HR of more than 20 bpm was observed. Conclusion: Dual-source CT scanners are considered to have the capability to provide diagnostic examinations even with high HR and arrhythmias. However, it is desirable to keep the mean heart rate below 65 bpm and heart rate fluctuation less than 20 bpm in order to reduce the radiation exposure

  15. [Design of Oxygen Saturation, Heart Rate, Respiration Rate Detection System Based on Smartphone of Android Operating System].

    Science.gov (United States)

    Zhu, Mingshan; Zeng, Bixin

    2015-03-01

    In this paper, we designed an oxygen saturation, heart rate, respiration rate monitoring system based on smartphone of android operating system, physiological signal acquired by MSP430 microcontroller and transmitted by Bluetooth module.

  16. SVM-Based Spectral Analysis for Heart Rate from Multi-Channel WPPG Sensor Signals

    Directory of Open Access Journals (Sweden)

    Jiping Xiong

    2017-03-01

    Full Text Available Although wrist-type photoplethysmographic (hereafter referred to as WPPG sensor signals can measure heart rate quite conveniently, the subjects’ hand movements can cause strong motion artifacts, and then the motion artifacts will heavily contaminate WPPG signals. Hence, it is challenging for us to accurately estimate heart rate from WPPG signals during intense physical activities. The WWPG method has attracted more attention thanks to the popularity of wrist-worn wearable devices. In this paper, a mixed approach called Mix-SVM is proposed, it can use multi-channel WPPG sensor signals and simultaneous acceleration signals to measurement heart rate. Firstly, we combine the principle component analysis and adaptive filter to remove a part of the motion artifacts. Due to the strong relativity between motion artifacts and acceleration signals, the further denoising problem is regarded as a sparse signals reconstruction problem. Then, we use a spectrum subtraction method to eliminate motion artifacts effectively. Finally, the spectral peak corresponding to heart rate is sought by an SVM-based spectral analysis method. Through the public PPG database in the 2015 IEEE Signal Processing Cup, we acquire the experimental results, i.e., the average absolute error was 1.01 beat per minute, and the Pearson correlation was 0.9972. These results also confirm that the proposed Mix-SVM approach has potential for multi-channel WPPG-based heart rate estimation in the presence of intense physical exercise.

  17. Real-time Continuous Assessment Method for Mental and Physiological Condition using Heart Rate Variability

    Science.gov (United States)

    Yoshida, Yutaka; Yokoyama, Kiyoko; Ishii, Naohiro

    It is necessary to monitor the daily health condition for preventing stress syndrome. In this study, it was proposed the method assessing the mental and physiological condition, such as the work stress or the relaxation, using heart rate variability at real time and continuously. The instantanuous heart rate (HR), and the ratio of the number of extreme points (NEP) and the number of heart beats were calculated for assessing mental and physiological condition. In this method, 20 beats heart rate were used to calculate these indexes. These were calculated in one beat interval. Three conditions, which are sitting rest, performing mental arithmetic and watching relaxation movie, were assessed using our proposed algorithm. The assessment accuracies were 71.9% and 55.8%, when performing mental arithmetic and watching relaxation movie respectively. In this method, the mental and physiological condition was assessed using only 20 regressive heart beats, so this method is considered as the real time assessment method.

  18. ARTiiFACT: a tool for heart rate artifact processing and heart rate variability analysis.

    Science.gov (United States)

    Kaufmann, Tobias; Sütterlin, Stefan; Schulz, Stefan M; Vögele, Claus

    2011-12-01

    The importance of appropriate handling of artifacts in interbeat interval (IBI) data must not be underestimated. Even a single artifact may cause unreliable heart rate variability (HRV) results. Thus, a robust artifact detection algorithm and the option for manual intervention by the researcher form key components for confident HRV analysis. Here, we present ARTiiFACT, a software tool for processing electrocardiogram and IBI data. Both automated and manual artifact detection and correction are available in a graphical user interface. In addition, ARTiiFACT includes time- and frequency-based HRV analyses and descriptive statistics, thus offering the basic tools for HRV analysis. Notably, all program steps can be executed separately and allow for data export, thus offering high flexibility and interoperability with a whole range of applications.

  19. Heart rate responses induced by acoustic tempo and its interaction with basal heart rate.

    Science.gov (United States)

    Watanabe, Ken; Ooishi, Yuuki; Kashino, Makio

    2017-03-07

    Many studies have revealed the influences of music on the autonomic nervous system (ANS). Since previous studies focused on the effects of acoustic tempo on the ANS, and humans have their own physiological oscillations such as the heart rate (HR), the effects of acoustic tempo might depend on the HR. Here we show the relationship between HR elevation induced by acoustic tempo and individual basal HR. Since high tempo-induced HR elevation requires fast respiration, which is based on sympatho-respiratory coupling, we controlled the participants' respiration at a faster rate (20 CPM) than usual (15 CPM). We found that sound stimuli with a faster tempo than the individual basal HR increased the HR. However, the HR increased following a gradual increase in the acoustic tempo only when the extent of the gradual increase in tempo was within a specific range (around + 2%/min). The HR did not follow the increase in acoustic tempo when the rate of the increase in the acoustic tempo exceeded 3% per minute. These results suggest that the effect of the sympatho-respiratory coupling underlying the HR elevation caused by a high acoustic tempo depends on the basal HR, and the strength and the temporal dynamics of the tempo.

  20. Dynamic neural networking as a basis for plasticity in the control of heart rate.

    Science.gov (United States)

    Kember, G; Armour, J A; Zamir, M

    2013-01-21

    A model is proposed in which the relationship between individual neurons within a neural network is dynamically changing to the effect of providing a measure of "plasticity" in the control of heart rate. The neural network on which the model is based consists of three populations of neurons residing in the central nervous system, the intrathoracic extracardiac nervous system, and the intrinsic cardiac nervous system. This hierarchy of neural centers is used to challenge the classical view that the control of heart rate, a key clinical index, resides entirely in central neuronal command (spinal cord, medulla oblongata, and higher centers). Our results indicate that dynamic networking allows for the possibility of an interplay among the three populations of neurons to the effect of altering the order of control of heart rate among them. This interplay among the three levels of control allows for different neural pathways for the control of heart rate to emerge under different blood flow demands or disease conditions and, as such, it has significant clinical implications because current understanding and treatment of heart rate anomalies are based largely on a single level of control and on neurons acting in unison as a single entity rather than individually within a (plastically) interconnected network. Copyright © 2012 Elsevier Ltd. All rights reserved.

  1. Heart Rate Monitors Promote Physical Education for Children

    Science.gov (United States)

    Tipton, Jan; Sander, Allan N.

    2004-01-01

    National health and fitness data suggests that a significant percentage of children are not on a pathway to leading healthy, physically active lifestyles. Many children are leading sedentary lifestyles due to a lack of opportunity, success, or self-motivation in physical activity. Programs that highlight the use of heart rate monitors offer a…

  2. Influence of Prolonged Spaceflight on Heart Rate and Oxygen Uptake Kinetics

    Science.gov (United States)

    Hoffmann, U.; Moore, A.; Drescher, U.

    2013-02-01

    During prolonged spaceflight, physical training is used to minimize cardiovascular deconditioning. Measurement of the kinetics of cardiorespiratory parameters, in particular the kinetic analysis of heart rate, respiratory and muscular oxygen uptake, provides useful information with regard to the efficiency and regulation of the cardiorespiratory system. Practically, oxygen uptake kinetics can only be measured at the lung site (V’O2 resp). The dynamics of V’O2 resp, however, is not identical with the dynamics at the site of interest: skeletal muscle. Eight Astronauts were tested pre- and post-flight using pseudo random binary workload changes between 30 and 80 W. Their kinetic responses of heart rate, respiratory as well as muscular V’O2 kinetics were estimated by using time-series analysis. Statistical analysis revealed that the kinetic responses of respiratory as well as muscular V’O2 kinetics are slowed post-flight than pre-flight. Heart rate seems not to be influenced following flight. The influence of other factors (e. g. astronauts’ exercise training) may impact these parameters and is an area for future studies.

  3. Estimation of physical work load by statistical analysis of the heart rate in a conveyor-belt worker.

    Science.gov (United States)

    Kontosic, I; Vukelić, M; Pancić, M; Kunisek, J

    1994-12-01

    Physical work load was estimated in a female conveyor-belt worker in a bottling plant. Estimation was based on continuous measurement and on calculation of average heart rate values in three-minute and one-hour periods and during the total measuring period. The thermal component of the heart rate was calculated by means of the corrected effective temperature, for the one-hour periods. The average heart rate at rest was also determined. The work component of the heart rate was calculated by subtraction of the resting heart rate and the heart rate measured at 50 W, using a regression equation. The average estimated gross energy expenditure during the work was 9.6 +/- 1.3 kJ/min corresponding to the category of light industrial work. The average estimated oxygen uptake was 0.42 +/- 0.06 L/min. The average performed mechanical work was 12.2 +/- 4.2 W, i.e. the energy expenditure was 8.3 +/- 1.5%.

  4. [Evaluation of heart impact in the 100 m extreme intensity sport using near-infrared non-invasive muscle oxygen detecting device and sports heart rate detection technology].

    Science.gov (United States)

    Wang, Pei-Yong; Long, Fei-Xiao; Fu, Lan-Ying; Li, Yue; Ding, Hai-Shu; Qu, An-Lian; Zhou, Xiao-Ping

    2010-02-01

    Using continuous two wavelength near-infrared technology to detect the variation in the consistency of oxygen hemoglobin in the muscle and the sports heart rate wireless real time collection technology, we devised the real time muscle tissue oxygenation and instantaneous heart rate experiment scheme and implemented it for the process of the 100 m run with two parameters given simultaneously. The experiment shows that the concentration of the oxygen hemoglobin in the muscle tissue continues decreasing after the end of the 100 m run, and the time interval between the moment when the concentration of the oxygen hemoglobin attains the minimum value and the moment when the athletes finish the 100 m run is (6.65 +/- 1.10) sec; while the heart rate continues increasing after the end of the 100 m run, and the time interval between the moment when the heart rate attains the maximum value and the moment when the athletes finish the 100 m run is (8.00 +/- 1.57) sec. The results show that the two wavelength near-infrared tissue oxygenation detection technology and the sports heart rate real time collection equipment can accurately measure the sports tissue oxygenation and the heart rate in the extreme intensity sport, and reveal the process of muscle oxygen transportation and consumption and its dynamic character with the heart rate in the extreme intensity sport.

  5. The modulatory effects of noradrenaline on vagal control of heart rate in the dogfish, Squalus acanthias.

    Science.gov (United States)

    Agnisola, Claudio; Randall, David J; Taylor, Edwin W

    2003-01-01

    The possible interactions between inhibitory vagal control of the heart and circulating levels of catecholamines in dogfish (Squalus acanthias) were studied using an in situ preparation of the heart, which retained intact its innervation from centrally cut vagus nerves. The response to peripheral vagal stimulation typically consisted of an initial cardiac arrest, followed by an escape beat, leading to renewed beating at a mean heart rate lower than the prestimulation rate (partial recovery). Cessation of vagal stimulation led to a transient increase in heart rate, above the prestimulation rate. This whole response was completely abolished by 10(-4) M atropine (a muscarinic cholinergic antagonist). The degree of vagal inhibition was evaluated in terms of both the initial, maximal cardiac interval and the mean heart rate during partial recovery, both expressed as a percentage of the prestimulation heart rate. The mean prestimulation heart rate of this preparation (36+/-4 beats min(-1)) was not affected by noradrenaline but was significantly reduced by 10(-4) M nadolol (a beta-adrenergic receptor antagonist), suggesting the existence of a resting adrenergic tone arising from endogenous catecholamines. The degree of vagal inhibition of heart rate varied with the rate of stimulation and was increased by the presence of 10(-8) M noradrenaline (the normal in vivo level in routinely active fish), while 10(-7) M noradrenaline (the in vivo level measured in disturbed or deeply hypoxic fish) reduced the cardiac response to vagal stimulation. In the presence of 10(-7) M noradrenaline, 10(-4) M nadolol further reduced the vagal response, while 10(-4) M nadolol + 10(-4) M phentolamine had no effect, indicating a complex interaction between adrenoreceptors, possibly involving presynaptic modulation of vagal inhibition.

  6. Heart Disease Death Rates Among Blacks and Whites Aged ≥35 Years — United States, 1968–2015

    Science.gov (United States)

    Van Dyke, Miriam; Greer, Sophia; Odom, Erika; Schieb, Linda; Vaughan, Adam; Kramer, Michael; Casper, Michele

    2018-01-01

    Problem/Condition Heart disease is the leading cause of death in the United States. In 2015, heart disease accounted for approximately 630,000 deaths, representing one in four deaths in the United States. Although heart disease death rates decreased 68% for the total population from 1968 to 2015, marked disparities in decreases exist by race and state. Period Covered 1968–2015. Description of System The National Vital Statistics System (NVSS) data on deaths in the United States were abstracted for heart disease using diagnosis codes from the eighth, ninth, and tenth revisions of the International Classification of Diseases (ICD-8, ICD-9, and ICD-10) for 1968–2015. Population estimates were obtained from NVSS files. National and state-specific heart disease death rates for the total population and by race for adults aged ≥35 years were calculated for 1968–2015. National and state-specific black-white heart disease mortality ratios also were calculated. Death rates were age standardized to the 2000 U.S. standard population. Joinpoint regression was used to perform time trend analyses. Results From 1968 to 2015, heart disease death rates decreased for the total U.S. population among adults aged ≥35 years, from 1,034.5 to 327.2 per 100,000 population, respectively, with variations in the magnitude of decreases by race and state. Rates decreased for the total population an average of 2.4% per year, with greater average decreases among whites (2.4% per year) than blacks (2.2% per year). At the national level, heart disease death rates for blacks and whites were similar at the start of the study period (1968) but began to diverge in the late 1970s, when rates for blacks plateaued while rates for whites continued to decrease. Heart disease death rates among blacks remained higher than among whites for the remainder of the study period. Nationwide, the black-white ratio of heart disease death rates increased from 1.04 in 1968 to 1.21 in 2015, with large increases

  7. Effects of atomoxetine on heart rhythm in children and adolescents.

    Science.gov (United States)

    Tanidir, Ibrahim Cansaran; Tanidir, Canan; Ozturk, Erkut; Bahali, Kayhan; Gunes, Hatice; Ergul, Yakup; Uneri, Ozden Sukran; Akdeniz, Celal; Tuzcu, Volkan

    2015-12-01

    The aim of this study was to examine the effects of atomoxetine on heart rhythm using 12-lead electrocardiography (ECG) and 24 h Holter monitoring. Children and adolescents who were diagnosed with attention deficit-hyperactivity disorder according to DSM-IV-TR were referred to a pediatric cardiology clinic for cardiologic examination before and after 4 or 5 weeks of atomoxetine treatment. Cardiac examination, complete blood count, biochemistry, thyroid function tests, 12-lead ECG and 24 h Holter monitoring were performed routinely in all patients. Each subject underwent 24 h Holter ECG monitoring before atomoxetine was started and after 4 or 5 weeks of effective dose atomoxetine treatment. Forty-one patients were included in this prospective study. No statistically significant change was found in QT, QTc or QT interval dispersion or blood pressure before and after 4 or 5 weeks of atomoxetine treatment. There was a statistically significant increase in heart rate (both during the day and at night) and QRS duration, and a statistically significant decrease in P wave dispersion. Three patients had rhythm disturbances. All of these three patients were asymptomatic and none of these arrhythmias reached clinical significance. Atomoxetine did not cause significant changes in ECG or Holter variables. In two patients, who had undiagnosed subclinical extrasystoles, extra beats were increased after 4th week of treatment, but still remained clinically insignificant. Before and after atomoxetine treatment, listening to the heart sounds for a longer time, may help clinicians to notice an extra beat. If an extra beat is identified then 24 Holter monitoring is recommended. © 2015 Japan Pediatric Society.

  8. Effect of newly synthesized compounds 44Bu and 444 on QRS -complex width and fast sodium current

    Czech Academy of Sciences Publication Activity Database

    Kilianová, A.; Bébarová, M.; Beránková, K.; Opatřilová, R.; Pásek, Michal; Bartošová, L.

    2010-01-01

    Roč. 79, č. 1 (2010), s. 41-49 ISSN 0001-7213 Institutional research plan: CEZ:AV0Z20760514 Keywords : 444 * 44Bu * QRS-complex * sodium current * rat Subject RIV: BO - Biophysics Impact factor: 0.534, year: 2010

  9. Electrodes as social glue: measuring heart rate promotes giving in the trust game.

    Science.gov (United States)

    Van Lange, Paul A M; Finkenauer, Catrin; Popma, Arne; van Vugt, Mark

    2011-06-01

    While physiological measures are increasingly used to help us understand the workings of interpersonal trust (and related behaviors), we know very little about the effects of such measures on trust. We examined the effects of a classic measure, the measurement of heart rate using a standard protocol, on behavioral trust in dyads of women who did not know each other. Behavioral trust was assessed in the trust game, in which the trustor decides how much money from their subject payment to give to a trustee, while knowing that the experimenter triples that amount before giving it to the trustee, after which the trustee decides how much money to return to the trustor. As predicted, we found greater levels of behavioral trust in the trust game, as well as greater returns by the trustees (which were accounted for by trustor's giving), in the heart rate (HR) than in no heart rate (NHR) measurement condition. Parallel findings were observed for self-reported trust. Findings are discussed in terms of the idea that the elusive effects of a protocol for measuring heart rate can cause pronounced effects on subsequent social interactions via enhanced interpersonal trust. 2011 Elsevier B.V. All rights reserved.

  10. Heart rate responses to autonomic challenges in obstructive sleep apnea.

    Directory of Open Access Journals (Sweden)

    Paul M Macey

    Full Text Available Obstructive sleep apnea (OSA is accompanied by structural alterations and dysfunction in central autonomic regulatory regions, which may impair dynamic and static cardiovascular regulation, and contribute to other syndrome pathologies. Characterizing cardiovascular responses to autonomic challenges may provide insights into central nervous system impairments, including contributions by sex, since structural alterations are enhanced in OSA females over males. The objective was to assess heart rate responses in OSA versus healthy control subjects to autonomic challenges, and, separately, characterize female and male patterns. We studied 94 subjects, including 37 newly-diagnosed, untreated OSA patients (6 female, age mean ± std: 52.1 ± 8.1 years; 31 male aged 54.3 ± 8.4 years, and 57 healthy control subjects (20 female, 50.5 ± 8.1 years; 37 male, 45.6 ± 9.2 years. We measured instantaneous heart rate with pulse oximetry during cold pressor, hand grip, and Valsalva maneuver challenges. All challenges elicited significant heart rate differences between OSA and control groups during and after challenges (repeated measures ANOVA, p<0.05. In post-hoc analyses, OSA females showed greater impairments than OSA males, which included: for cold pressor, lower initial increase (OSA vs. control: 9.5 vs. 7.3 bpm in females, 7.6 vs. 3.7 bpm in males, OSA delay to initial peak (2.5 s females/0.9 s males, slower mid-challenge rate-of-increase (OSA vs. control: -0.11 vs. 0.09 bpm/s in females, 0.03 vs. 0.06 bpm/s in males; for hand grip, lower initial peak (OSA vs. control: 2.6 vs. 4.6 bpm in females, 5.3 vs. 6.0 bpm in males; for Valsalva maneuver, lower Valsalva ratio (OSA vs. control: 1.14 vs. 1.30 in females, 1.29 vs. 1.34 in males, and OSA delay during phase II (0.68 s females/1.31 s males. Heart rate responses showed lower amplitude, delayed onset, and slower rate changes in OSA patients over healthy controls, and impairments may be more pronounced in

  11. Performance Analysis of Ten Common QRS Detectors on Different ECG Application Cases

    Directory of Open Access Journals (Sweden)

    Feifei Liu

    2018-01-01

    Full Text Available A systematical evaluation work was performed on ten widely used and high-efficient QRS detection algorithms in this study, aiming at verifying their performances and usefulness in different application situations. Four experiments were carried on six internationally recognized databases. Firstly, in the test of high-quality ECG database versus low-quality ECG database, for high signal quality database, all ten QRS detection algorithms had very high detection accuracy (F1 >99%, whereas the F1 results decrease significantly for the poor signal-quality ECG signals (all 95% except RS slope algorithm with 94.24% on normal ECG database and 94.44% on arrhythmia database. Thirdly, for the paced rhythm ECG database, all ten algorithms were immune to the paced beats (>94% except the RS slope method, which only output a low F1 result of 78.99%. At last, the detection accuracies had obvious decreases when dealing with the dynamic telehealth ECG signals (all <80% except OKB algorithm with 80.43%. Furthermore, the time costs from analyzing a 10 s ECG segment were given as the quantitative index of the computational complexity. All ten algorithms had high numerical efficiency (all <4 ms except RS slope (94.07 ms and sixth power algorithms (8.25 ms. And OKB algorithm had the highest numerical efficiency (1.54 ms.

  12. Heart rate variability among caregivers of chronically bedridden patients

    Directory of Open Access Journals (Sweden)

    Amrith Pakkala

    2013-01-01

    Full Text Available Background: Caregivers of chronically bedridden patients are likely to suffer from mental and physical exhaustion leading to stress. This is important in view of the prevailing socioeconomic as well as the healthcare system available in a developing country like India. Therefore, the present study is designed to measure heart rate variability (HRV among this special group of population who give care to long-term bedridden patients. Materials and Methods: Fifteen female subjects were enrolled from among attendants of patients admitted with an immediate history of a cerebrovascular accident with locomotor deficits, who required constant care. They were free from any type of physical and mental health issues, nonsmokers and nonaddicts. Each care giver was subjected to HRV analysis on three occasions: The first record was performed in the 1 st week of their arrival in the hospital as caregivers. The second observation was recorded after 3 months of caregiving. The final HRV analysis was done after 6 months of care giving. Two types of parameters were analyzed: Time domain and frequency domain. Statistical analysis was done using paired t-test. Results: Both the HRV parameters: Time and frequency domain, showed decreased values during the 3 rd and 6 th month recording as compared to the 1 st week recording. The decrease is much more during the 6 th month recording as compared to the 3 rd month recording. Statistically significant decrease is observed in mean RR interval, heart rate, very low frequency (VLF, and LF only when the 1 st week recording is compared with the 3 rd month recording, but when the 1 st week recording was compared with the 6 th month recording significant decrease was found in mean RR interval and heart rate. Conclusion: Subjects involved in taking care of chronically ill bedridden patients are likely to undergo a lot of physical and mental stress, thus affecting their autonomic status. HRV analysis using short term

  13. Association between smoking and heart rate variability among individuals with depression.

    Science.gov (United States)

    Harte, Christopher B; Liverant, Gabrielle I; Sloan, Denise M; Kamholz, Barbara W; Rosebrock, Laina E; Fava, Maurizio; Kaplan, Gary B

    2013-08-01

    Both depression and smoking have been independently associated with lower heart rate variability (HRV), suggesting dysregulation of cardiac autonomic function. However, no studies have systematically explored the effects of smoking on HRV among depressed patients. This study examined differences in HRV based on smoking status among depressed individuals. Electrophysiological data were examined among 77 adult outpatients without a history of myocardial infarction, who met criteria for major depressive disorder or dysthymia. Frequency domain [low frequency (LF), high frequency (HF), LF/HF ratio, respiratory sinus arrhythmia (RSA)] parameters of HRV, and heart rate and inter-beat interval (IBI) data were compared between depressed smokers (n = 34) and depressed nonsmokers (n = 44). After controlling for covariates, depressed smokers, compared to depressed nonsmokers, displayed significantly lower LF, HF, and RSA. Among depressed patients, smoking is associated with significantly lower HRV, indicating dysregulated autonomic modulation of the heart.

  14. Reduced dietary sodium intake increases heart rate. A meta-analysis of 63 randomized controlled trials including 72 study populations.

    Directory of Open Access Journals (Sweden)

    Niels eGraudal

    2016-03-01

    Full Text Available Reduced dietary sodium intake (sodium reduction increases heart rate in some studies of animals and humans. As heart rate is independently associated with the development of heart failure and increased risk of premature death a potential increase in heart rate could be a harmful side-effect of sodium reduction. The purpose of the present meta-analysis was to investigate the effect of sodium reduction on heart rate. Relevant studies were retrieved from an updated pool of 176 randomized controlled trials (RCTs published in the period 1973–2014. 63 of the RCTs including 72 study populations reported data on heart rate. In a meta-analysis of these data sodium reduction increased heart rate with 1.65 beats per minute [95% CI: 1.19, 2.11], p < 0.00001, corresponding to 2.4% of the baseline heart rate. This effect was independent of baseline blood pressure. In conclusion sodium reduction increases heart rate by as much (2.4% as it decreases blood pressure (2.5%. This side-effect, which may cause harmful health effects, contributes to the need for a revision of the present dietary guidelines.

  15. Heart rate variability is reduced during acute uncomplicated diverticulitis

    DEFF Research Database (Denmark)

    Huang, Chenxi; Alamili, Mahdi; Rosenberg, Jacob

    2016-01-01

    BACKGROUND: The aim of the present study was to report the trajectory of heart rate variability (HRV) indices during a low-grade acute inflammation and their associations to biomarkers for infection. METHODS: Twelve patients with uncomplicated acute diverticulitis completed this observational study...

  16. Chronic intermittent hypoxia-hypercapnia blunts heart rate responses and alters neurotransmission to cardiac vagal neurons.

    Science.gov (United States)

    Dyavanapalli, Jhansi; Jameson, Heather; Dergacheva, Olga; Jain, Vivek; Alhusayyen, Mona; Mendelowitz, David

    2014-07-01

    Patients with obstructive sleep apnoea experience chronic intermittent hypoxia-hypercapnia (CIHH) during sleep that elicit sympathetic overactivity and diminished parasympathetic activity to the heart, leading to hypertension and depressed baroreflex sensitivity. The parasympathetic control of heart rate arises from pre-motor cardiac vagal neurons (CVNs) located in nucleus ambiguus (NA) and dorsal motor nucleus of the vagus (DMNX). The mechanisms underlying diminished vagal control of heart rate were investigated by studying the changes in blood pressure, heart rate, and neurotransmission to CVNs evoked by acute hypoxia-hypercapnia (H-H) and CIHH. In vivo telemetry recordings of blood pressure and heart rate were obtained in adult rats during 4 weeks of CIHH exposure. Retrogradely labelled CVNs were identified in an in vitro brainstem slice preparation obtained from adult rats exposed either to air or CIHH for 4 weeks. Postsynaptic inhibitory or excitatory currents were recorded using whole cell voltage clamp techniques. Rats exposed to CIHH had increases in blood pressure, leading to hypertension, and blunted heart rate responses to acute H-H. CIHH induced an increase in GABAergic and glycinergic neurotransmission to CVNs in NA and DMNX, respectively; and a reduction in glutamatergic neurotransmission to CVNs in both nuclei. CIHH blunted the bradycardia evoked by acute H-H and abolished the acute H-H evoked inhibition of GABAergic transmission while enhancing glycinergic neurotransmission to CVNs in NA. These changes with CIHH inhibit CVNs and vagal outflow to the heart, both in acute and chronic exposures to H-H, resulting in diminished levels of cardioprotective parasympathetic activity to the heart as seen in OSA patients. © 2014 The Authors. The Journal of Physiology © 2014 The Physiological Society.

  17. Physiological and performance adaptations to an in-season soccer camp in the heat: Associations with heart rate and heart rate variability

    DEFF Research Database (Denmark)

    Buchheit, M; Voss, S C; Nybo, Lars

    2011-01-01

    The aim of the present study was to examine the associations between adaptive responses to an in-season soccer training camp in the heat and changes in submaximal exercising heart rate (HRex, 5-min run at 9 ¿km/h), postexercise HR recovery (HRR) and HR variability (HRV). Fifteen well-trained but ......The aim of the present study was to examine the associations between adaptive responses to an in-season soccer training camp in the heat and changes in submaximal exercising heart rate (HRex, 5-min run at 9 ¿km/h), postexercise HR recovery (HRR) and HR variability (HRV). Fifteen well......-trained but non-heat-acclimatized male adult players performed a training week in Qatar (34.6¿±¿1.9°C wet bulb globe temperature). HRex, HRR, HRV (i.e. the standard deviation of instantaneous beat-to-beat R-R interval variability measured from Poincaré plots SD1, a vagal-related index), creatine kinase (CK...... at the beginning and at the end of the training week. Throughout the intervention, HRex and HRV showed decreasing (P¿...

  18. Continuous ECG Monitoring in Patients With Acute Coronary Syndrome or Heart Failure: EASI Versus Gold Standard.

    Science.gov (United States)

    Lancia, Loreto; Toccaceli, Andrea; Petrucci, Cristina; Romano, Silvio; Penco, Maria

    2018-05-01

    The purpose of the study was to compare the EASI system with the standard 12-lead surface electrocardiogram (ECG) for the accuracy in detecting the main electrocardiographic parameters (J point, PR, QT, and QRS) commonly monitored in patients with acute coronary syndromes or heart failure. In this observational comparative study, 253 patients who were consecutively admitted to the coronary care unit with acute coronary syndrome or heart failure were evaluated. In all patients, two complete 12-lead ECGs were acquired simultaneously. A total of 6,072 electrocardiographic leads were compared (3,036 standard and 3,036 EASI). No significant differences were found between the investigate parameters of the two measurement methods, either in patients with acute coronary syndrome or in those with heart failure. This study confirmed the accuracy of the EASI system in monitoring the main ECG parameters in patients admitted to the coronary care unit with acute coronary syndrome or heart failure.

  19. Prognostic value of ambulatory heart rate revisited in 6928 subjects from 6 populations

    DEFF Research Database (Denmark)

    Hansen, Tine Willum; Thijs, Lutgarde; Staessen, Jan A.

    2008-01-01

    The evidence relating mortality and morbidity to heart rate remains inconsistent. We performed 24-hour ambulatory blood pressure monitoring in 6928 subjects (not on beta-blockers; mean age: 56.2 years; 46.5% women) enrolled in prospective population studies in Denmark, Belgium, Japan, Sweden......, Uruguay, and China. We computed standardized hazard ratios for heart rate, while stratifying for cohort, and adjusting for blood pressure and other cardiovascular risk factors. Over 9.6 years (median), 850, 325, and 493 deaths accrued for total, cardiovascular, and noncardiovascular mortality......, respectively. The incidence of fatal combined with nonfatal end points was 805, 363, 439, and 324 for cardiovascular, stroke, cardiac, and coronary events, respectively. Twenty-four-hour heart rate predicted total (hazard ratio: 1.15) and noncardiovascular (hazard ratio: 1.18) mortality but not cardiovascular...

  20. Heart Rate Variability: New Perspectives on Physiological Mechanisms, Assessment of Self-regulatory Capacity, and Health risk.

    Science.gov (United States)

    McCraty, Rollin; Shaffer, Fred

    2015-01-01

    Heart rate variability, the change in the time intervals between adjacent heartbeats, is an emergent property of interdependent regulatory systems that operates on different time scales to adapt to environmental and psychological challenges. This article briefly reviews neural regulation of the heart and offers some new perspectives on mechanisms underlying the very low frequency rhythm of heart rate variability. Interpretation of heart rate variability rhythms in the context of health risk and physiological and psychological self-regulatory capacity assessment is discussed. The cardiovascular regulatory centers in the spinal cord and medulla integrate inputs from higher brain centers with afferent cardiovascular system inputs to adjust heart rate and blood pressure via sympathetic and parasympathetic efferent pathways. We also discuss the intrinsic cardiac nervous system and the heart-brain connection pathways, through which afferent information can influence activity in the subcortical, frontocortical, and motor cortex areas. In addition, the use of real-time HRV feedback to increase self-regulatory capacity is reviewed. We conclude that the heart's rhythms are characterized by both complexity and stability over longer time scales that reflect both physiological and psychological functional status of these internal self-regulatory systems.

  1. Gonadal hormones and heart rate as an emotional response

    NARCIS (Netherlands)

    de Loos, Wolter Statius

    1988-01-01

    Animai experiments may give information on the physiology of hormones under stress conditions. The model for the investigation of acute emotional stress in animals that has been chosen permits the study of heart rate in freely moving laboratory rats as a sensitive psychophysiological parameter, This

  2. Blood pressure and heart rate adjustment following acute Frenkel's ...

    African Journals Online (AJOL)

    Background: Frenkel's ambulatory activity has been routinely employed by physiotherapists for rehabilitation of gait coordination, however, its immediate influence on blood pressure and heart rate has not been investigated. Objective: To investigate the acute effect of Frenkel's ambulatory activity on blood pressure and ...

  3. Heart Rate and Oxygen Saturation Change Patterns During 6-min Walk Test in Subjects With Chronic Thromboembolic Pulmonary Hypertension.

    Science.gov (United States)

    Inagaki, Takeshi; Terada, Jiro; Yahaba, Misuzu; Kawata, Naoko; Jujo, Takayuki; Nagashima, Kengo; Sakao, Seiichiro; Tanabe, Nobuhiro; Tatsumi, Koichiro

    2017-12-26

    The 6-min walk test (6MWT) is commonly performed to assess functional status in patients with chronic thromboembolic pulmonary hypertension. However, changes in heart rate and oxygen saturation ( S pO 2 ) patterns during 6MWT in patients with chronic thromboembolic pulmonary hypertension remain unclear. Thirty-one subjects with chronic thromboembolic pulmonary hypertension were retrospectively evaluated to examine the relationships between the change in heart rateheart rate), heart rate acceleration time, slope of heart rate acceleration, heart rate recovery during the first minute after 6MWT (HRR1), change in S pO 2 (Δ S pO 2 ), S pO 2 reduction time, and S pO 2 recovery time during 6MWT, and the severity of pulmonary hemodynamics assessed by right heart catheterization and echocardiography. Subjects with severe chronic thromboembolic pulmonary hypertension had significantly longer heart rate acceleration time (144.9 ± 63.9 s vs 96.0 ± 42.5 s, P = .033), lower Δheart rate (47.4 ± 16.9 vs 61.8 ± 13.6 beats, P = .02), and lower HRR1 (13.3 ± 9.0 beats vs 27.1 ± 9.2 beats, P pulmonary hypertension. Subjects with severe chronic thromboembolic pulmonary hypertension also had significantly longer S pO 2 reduction time (178.3 ± 70.3 s vs 134.3 ± 58.4 s, P = .03) and S pO 2 recovery time (107.6 ± 35.3 s vs 69.8 ± 32.7 s, P = .004) than did subjects with mild chronic thromboembolic pulmonary hypertension. Multivariate linear regression analysis showed only mean pulmonary arterial pressure independently was associated with heart rate acceleration time and slope of heart rate acceleration. Heart rate and S pO 2 change patterns during 6MWT is predominantly associated with pulmonary hemodynamics in subjects with chronic thromboembolic pulmonary hypertension. Evaluating heart rate and S pO 2 change patterns during 6MWT may serve a safe and convenient way to follow the change in pulmonary hemodynamics. Copyright © 2017 by Daedalus Enterprises.

  4. A healthy heart is not a metronome: An integrative review of the heart’s anatomy and heart rate variability

    Directory of Open Access Journals (Sweden)

    Fredric Bruce Shaffer

    2014-09-01

    Full Text Available Heart rate variability (HRV, the change in the time intervals between adjacent heartbeats, is an emergent property of interdependent regulatory systems that operate on different time scales to adapt to challenges and achieve optimal performance. This article briefly reviews neural regulation of the heart, and its basic anatomy, the cardiac cycle, and the sinoatrial and atrioventricular pacemakers. The cardiovascular regulation center in the medulla integrates sensory information and input from higher brain centers, and afferent cardiovascular system inputs to adjust heart rate and blood pressure via sympathetic and parasympathetic efferent pathways. This article reviews sympathetic and parasympathetic influences on the heart, and examines the interpretation of HRV and the association between reduced HRV, risk of disease and mortality, and the loss of regulatory capacity. This article also discusses the intrinsic cardiac nervous system and the heart-brain connection, through which afferent information can influence activity in the subcortical and frontocortical areas, and motor cortex. It also considers new perspectives on the putative underlying physiological mechanisms and properties of the ultra-low-frequency (ULF, very-low-frequency (VLF, low-frequency (LF, and high-frequency (HF bands. Additionally, it reviews the most common time and frequency domain measurements as well as standardized data collection protocols. In its final section, this article integrates Porges’ polyvagal theory, Thayer and colleagues’ neurovisceral integration model, Lehrer, Vaschillo, and Vaschillo’s resonance frequency model, and the Institute of HeartMath’s coherence model. The authors conclude that a coherent heart is not a metronome because its rhythms are characterized by both complexity and stability over longer time scales. Future research should expand understanding of how the heart and its intrinsic nervous system influence the brain.

  5. Heart rate variability alters cardiac repolarization and electromechanical dynamics.

    Science.gov (United States)

    Phadumdeo, Vrishti M; Weinberg, Seth H

    2018-04-07

    Heart rate continuously varies due to autonomic regulation, stochasticity in pacemaking, and circadian rhythm, collectively termed heart rate variability (HRV), during normal physiological conditions. Low HRV is clinically associated with an elevated risk of cardiac arrhythmias. Alternans, a beat-to-beat alternation in action potential duration (APD) and/or intracellular calcium (Ca) transient, is a well-known risk factor associated with cardiac arrhythmias that is typically studied under conditions of a constant pacing rate, i.e., the absence of HRV. In this study, we investigate the effects of HRV on the interplay between APD, Ca, and electromechanical properties, employing a nonlinear discrete-time map model that governs APD and intracellular Ca cycling with a stochastic pacing period. We find that HRV can decrease variation in APD and peak Ca at fast pacing rates for which alternans is present. Further, increased HRV typically disrupts the alternating pattern for both APD and peak Ca and weakens the correlation between APD and peak Ca, thus decoupling Ca-mediated instabilities from repolarization alternation. We find that the efficacy of these effects is regulated by the sarcoplasmic reticulum Ca uptake rate. Overall, these results demonstrate that HRV disrupts arrhythmogenic alternans and suggests that HRV may be a significant factor in preventing life-threatening arrhythmias. Copyright © 2018 Elsevier Ltd. All rights reserved.

  6. Validity of a heart rate monitor during work in the laboratory and on the Space Shuttle

    Science.gov (United States)

    Moore, A. D. Jr; Lee, S. M.; Greenisen, M. C.; Bishop, P.

    1997-01-01

    Accurate heart rate measurement during work is required for many industrial hygiene and ergonomics situations. The purpose of this investigation was to determine the validity of heart rate measurements obtained by a simple, lightweight, commercially available wrist-worn heart rate monitor (HRM) during work (cycle exercise) sessions conducted in the laboratory and also during the particularly challenging work environment of space flight. Three different comparisons were made. The first compared HRM data to simultaneous electrocardiogram (ECG) recordings of varying heart rates that were generated by an ECG simulator. The second compared HRM data to ECG recordings collected during work sessions of 14 subjects in the laboratory. Finally, ECG downlink and HRM data were compared in four astronauts who performed cycle exercise during space flight. The data were analyzed using regression techniques. The results were that the HRM recorded virtually identical heart rates compared with ECG recordings for the data set generated by an ECG simulator. The regression equation for the relationship between ECG versus HRM heart rate data during work in the laboratory was: ECG HR = 0.99 x (HRM) + 0.82 (r2 = 0.99). Finally, the agreement between ECG downlink data and HRM data during space flight was also very high, with the regression equation being: Downlink ECG HR = 1.05 x (HRM) -5.71 (r2 = 0.99). The results of this study indicate that the HRM provides accurate data and may be used to reliably obtain valid data regarding heart rate responses during work.

  7. The effect of sport on computerized electrocardiogram measurements in college athletes.

    Science.gov (United States)

    Gademan, Maaike G J; Uberoi, Abhimanyu; Le, Vy-Van; Mandic, Sandra; van Oort, Eddy R; Myers, Jonathan; Froelicher, Victor F

    2012-02-01

    Broad criteria for abnormal electrocardiogram (ECG) findings, requiring additional testing, have been recommended for preparticipation exams (PPE) of athletes. As these criteria have not considered the sport in which athletes participate, we examined the effect of sports on the computerized ECG measurements obtained in college athletes. During the Stanford 2007 PPE, computerized 12-lead ECGs (Schiller AG) were obtained in 641 athletes (350 male/291 female, age 19.5 ± 2 years). Athletes were engaged in 22 different sports and were grouped into 16 categories: baseball/softball, basketball, crew, crosscountry, fencing, field events, football linemen, football other positions, golf, gymnastics, racquet sports, sailing, track/field, volleyball, water sports, and wrestling. The analysis focused on ECG leads V2, aVF and V5 which provide a three-dimensional representation of the heart's electrical activity. As marked ECG differences exist between males and females, the data are presented by gender. In males, ANOVA analysis yielded significant ECG differences between sports for heart rate, QRS duration, QTc, J-amplitude in V2 and V5, spatial vector length (SVL) of the P wave, SVL R wave, and SVL T wave, and RS(sum) (p sports were found for heart rate, QRS duration, QRS axis and SVL T wave (p sports, and these differences were more apparent in males than females. Therefore, sport-specific ECG criteria for abnormal ECG findings should be developed to obtain a more useful approach to ECG screening in athletes.

  8. Evaluation of the influence of change in heart rate on left ventricular diastolic function indices

    International Nuclear Information System (INIS)

    Kimura, Motomasa; Yamagishi, Hiroaki; Seino, Yasuyuki; Odano, Ikuo; Sakai, Kunio; Yamamoto, Tomohiko; Tsuda, Takashi

    1988-01-01

    In order to assess the influence of change in heart rate on left ventricular diastolic function indices, ECG gated cardiac pool study was performed in 6 patients with implanted programmable AAI pacemakers. Heart rate was changed by atrial pacing from 50 to 120 beats/min, every 10 beats/min. The filling fraction during first third of diastole (1/3FF), the peak filling rate (PFR), mean first third filling rate (1/3FR-mean) and early filling volume ratio (%EFV), being used as the indices of left ventricular diastolic performance, were assessed. In accordance with increase in heart rate, 1/3FF decreased significantly. PFR were fairly stable from 50 to 80 beats/min, but increased significantly from 90 to 120 beats/min. 1/3FR-mean and %EFV did not change significantly, but 1/3FR-mean showed decreasing tendency and %EFV showed increasing tendency as the heart rate was increased. %EFV was more changeable index than other indices among clinical cases. These results indicate that PFR and 1/3FR-mean were appropriate diastolic phase indices at rest. (author)

  9. Paradoxical dissociation between heart rate and heart rate variability following different modalities of exercise in individuals with metabolic syndrome: The RESOLVE study.

    Science.gov (United States)

    Boudet, Gil; Walther, Guillaume; Courteix, Daniel; Obert, Philippe; Lesourd, Bruno; Pereira, Bruno; Chapier, Robert; Vinet, Agnès; Chamoux, Alain; Naughton, Geraldine; Poirier, Paul; Dutheil, Frédéric

    2017-02-01

    Aims To analyse the effects of different modalities of exercise training on heart rate variability (HRV) in individuals with metabolic syndrome (MetS). Methods and results Eighty MetS participants (aged 50-70 years) were housed and managed in an inpatient medical centre for 21 days, including weekends. Physical activity and food intake/diet were intensively monitored. Participants were randomly assigned into three training groups, differing only by intensity of exercise: moderate-endurance-moderate-resistance ( re), high-resistance-moderate-endurance ( Re), and moderate-resistance-high-endurance ( rE). HRV was recorded before and after the intervention by 24-hour Holter electrocardiogram. Although mean 24-hour heart rate decreased more in Re than re (-11.6 ± 1.6 vs. -4.8 ± 2.1%; P = 0.010), low frequency/high frequency decreased more in re than Re (-20.4 ± 5.5% vs. + 20.4 ± 9.1%; P = 0.002) and rE (-20.4 ± 5.5% vs. -0.3 ± 11.1%; P = 0.003). Very low frequency increased more in Re than re (+121.2 ± 35.7 vs. 42.9 ± 11.3%; P = 0.004). For all HRV parameters, rE ranged between re and Re values. Low frequency/high frequency changes were linked with visceral fat loss only in re (coefficient 5.9, 95% CI 1.9-10.0; P = 0.004). By day 21, HRV parameters of MetS groups (heart rate -8.6 ± 1.0%, standard deviation of R-R intervals + 34.0 ± 6.6%, total power + 63.3 ± 11.1%; P < 0.001) became closer to values of 50 aged-matched healthy controls. Conclusions A 3-week residential programme with intensive volumes of physical activity (15-20 hours per week) enhanced HRV in individuals with MetS. Participants with moderate intensity of training had greater improvements in sympathovagal balance, whereas those with high intensity in resistance training had greater decreases in heart rate and greater increases in very low frequency. Modality-specific relationships were observed between enhanced HRV

  10. National trends in heart failure hospitalization rates in Slovenia 2004-2012.

    Science.gov (United States)

    Omersa, Daniel; Farkas, Jerneja; Erzen, Ivan; Lainscak, Mitja

    2016-11-01

    Heart failure (HF) hospitalization rates are decreasing in western Europe, but little is known about trends in central and east European countries. We analysed the Slovenian national hospitalization database to determine the burden of HF hospitalization. The Slovenian National Hospital Discharge Registry was searched for HF hospitalizations between 2004 and 2012 in patients aged ≥20 years. A total of 55 531 main HF hospitalizations (43 636 first HF hospitalizations) in 34 406 patients (median age 78 years, 55% female) were recorded. The most common co-morbidities were arterial hypertension (54.3%), atrial fibrillation (40.6%), diabetes mellitus (24.5%), and ischaemic heart disease (21.9%). The number of age-standardized main and first HF hospitalizations per 100 000 population decreased from 249 to 232 (7.1%, P = 0.002) and from 467 to 435 (6.8%, P = 0.074), respectively. Crude main and first HF hospitalization rates increased from 249 to 298 (19.8%, P Slovenia, standardized HF hospitalization rates have decreased but the crude HF hospitalization burden has increased. Readmissions were associated with established cardiovascular risk factors. © 2016 The Authors. European Journal of Heart Failure © 2016 European Society of Cardiology.

  11. Heart rate and flow velocity variability as determined from umbilical Doppler velocimetry at 10-20 weeks of gestation.

    Science.gov (United States)

    Ursem, N T; Struijk, P C; Hop, W C; Clark, E B; Keller, B B; Wladimiroff, J W

    1998-11-01

    1. The aim of this study was to define from umbilical artery flow velocity waveforms absolute peak systolic and time-averaged velocity, fetal heart rate, fetal heart rate variability and flow velocity variability, and the relation between fetal heart rate and velocity variables in early pregnancy.2.A total of 108 women presenting with a normal pregnancy from 10 to 20 weeks of gestation consented to participate in a cross-sectional study design. Doppler ultrasound recordings were made from the free-floating loop of the umbilical cord.3. Umbilical artery peak systolic and time-averaged velocity increased at 10-20 weeks, whereas fetal heart rate decreased at 10-15 weeks of gestation and plateaued thereafter. Umbilical artery peak systolic velocity variability and fetal heart rate variability increased at 10-20 and 15-20 weeks respectively.4. The inverse relationship between umbilical artery flow velocity and fetal heart rate at 10-15 weeks of gestation suggests that the Frank-Starling mechanism regulates cardiovascular control as early as the late first and early second trimesters of pregnancy. A different underlying mechanism is suggested for the observed variability profiles in heart rate and umbilical artery peak systolic velocity. It is speculated that heart rate variability is mediated by maturation of the parasympathetic nervous system, whereas peak systolic velocity variability reflects the activation of a haemodynamic feedback mechanism.

  12. Heart rate reveals torpor at high body temperatures in lowland tropical free-tailed bats.

    Science.gov (United States)

    O'Mara, M Teague; Rikker, Sebastian; Wikelski, Martin; Ter Maat, Andries; Pollock, Henry S; Dechmann, Dina K N

    2017-12-01

    Reduction in metabolic rate and body temperature is a common strategy for small endotherms to save energy. The daily reduction in metabolic rate and heterothermy, or torpor, is particularly pronounced in regions with a large variation in daily ambient temperature. This applies most strongly in temperate bat species (order Chiroptera), but it is less clear how tropical bats save energy if ambient temperatures remain high. However, many subtropical and tropical species use some daily heterothermy on cool days. We recorded the heart rate and the body temperature of free-ranging Pallas' mastiff bats ( Molossus molossus ) in Gamboa, Panamá, and showed that these individuals have low field metabolic rates across a wide range of body temperatures that conform to high ambient temperature. Importantly, low metabolic rates in controlled respirometry trials were best predicted by heart rate, and not body temperature . Molossus molossus enter torpor-like states characterized by low metabolic rate and heart rates at body temperatures of 32°C, and thermoconform across a range of temperatures. Flexible metabolic strategies may be far more common in tropical endotherms than currently known.

  13. Wavelet and receiver operating characteristic analysis of heart rate variability

    Science.gov (United States)

    McCaffery, G.; Griffith, T. M.; Naka, K.; Frennaux, M. P.; Matthai, C. C.

    2002-02-01

    Multiresolution wavelet analysis has been used to study the heart rate variability in two classes of patients with different pathological conditions. The scale dependent measure of Thurner et al. was found to be statistically significant in discriminating patients suffering from hypercardiomyopathy from a control set of normal subjects. We have performed Receiver Operating Characteristc (ROC) analysis and found the ROC area to be a useful measure by which to label the significance of the discrimination, as well as to describe the severity of heart dysfunction.

  14. Heritability of ECG Biomarkers in the Netherlands Twin Registry Measured from Holter ECGs.

    Directory of Open Access Journals (Sweden)

    Emily C Hodkinson

    2016-04-01

    Full Text Available INTRODUCTIONThe resting ECG is the most commonly used tool to assess cardiac electrophysiology. Previous studies have estimated heritability of ECG parameters based on these snapshots of the cardiac electrical activity. In this study we set out to determine whether analysis of heart rate specific data from Holter ECGs allows more complete assessment of the heritability of ECG parameters.METHODS and RESULTSHolter ECGs were recorded from 221 twin pairs and analyzed using a multi-parameter beat binning approach. Heart rate dependent estimates of heritability for QRS duration, QT interval, Tpeak–Tend and Theight were calculated using structural equation modelling. QRS duration is largely determined by environmental factors whereas repolarization is primarily genetically determined. Heritability estimates of both QT interval and Theight were significantly higher when measured from Holter compared to resting ECGs and the heritability estimate of each was heart rate dependent. Analysis of the genetic contribution to correlation between repolarization parameters demonstrated that covariance of individual ECG parameters at different heart rates overlap but at each specific heart rate there was relatively little overlap in the genetic determinants of the different repolarization parameters.CONCLUSIONSHere we present the first study of heritability of repolarization parameters measured from Holter ECGs. Our data demonstrate that higher heritability can be estimated from the Holter than the resting ECG and reveals rate dependence in the genetic – environmental determinants of the ECG that has not previously been tractable. Future applications include deeper dissection of the ECG of participants with inherited cardiac electrical disease.

  15. Attenuated heart rate response is associated with hypocretin deficiency in patients with narcolepsy.

    Science.gov (United States)

    Sorensen, Gertrud Laura; Knudsen, Stine; Petersen, Eva Rosa; Kempfner, Jacob; Gammeltoft, Steen; Sorensen, Helge Bjarup Dissing; Jennum, Poul

    2013-01-01

    Several studies have suggested that hypocretin-1 may influence the cerebral control of the cardiovascular system. We analyzed whether hypocretin-1 deficiency in narcolepsy patients may result in a reduced heart rate response. We analyzed the heart rate response during various sleep stages from a 1-night polysomnography in patients with narcolepsy and healthy controls. The narcolepsy group was subdivided by the presence of +/- cataplexy and +/- hypocretin-1 deficiency. Sleep laboratory studies conducted from 2001-2011. In total 67 narcolepsy patients and 22 control subjects were included in the study. Cataplexy was present in 46 patients and hypocretin-1 deficiency in 38 patients. None. All patients with narcolepsy had a significantly reduced heart rate response associated with arousals and leg movements (P hypocretin-1 deficiency and cataplexy groups compared with patients with normal hypocretin-1 levels (P hypocretin-1 deficiency significantly predicted the heart rate response associated with arousals in both REM and non-REM in a multivariate linear regression. Our results show that autonomic dysfunction is part of the narcoleptic phenotype, and that hypocretin-1 deficiency is the primary predictor of this dysfunction. This finding suggests that the hypocretin system participates in the modulation of cardiovascular function at rest.

  16. Randomized controlled trial of relaxation music to reduce heart rate in patients undergoing cardiac CT.

    Science.gov (United States)

    Ng, Ming Yen; Karimzad, Yasser; Menezes, Ravi J; Wintersperger, Bernd J; Li, Qin; Forero, Julian; Paul, Narinder S; Nguyen, Elsie T

    2016-10-01

    To evaluate the heart rate lowering effect of relaxation music in patients undergoing coronary CT angiography (CCTA), pulmonary vein CT (PVCT) and coronary calcium score CT (CCS). Patients were randomised to a control group (i.e. standard of care protocol) or to a relaxation music group (ie. standard of care protocol with music). The groups were compared for heart rate, radiation dose, image quality and dose of IV metoprolol. Both groups completed State-Trait Anxiety Inventory anxiety questionnaires to assess patient experience. One hundred and ninety-seven patients were recruited (61.9 % males); mean age 56y (19-86 y); 127 CCTA, 17 PVCT, 53 CCS. No significant difference in heart rate, radiation dose, image quality, metoprolol dose and anxiety scores. 86 % of patients enjoyed the music. 90 % of patients in the music group expressed a strong preference to have music for future examinations. The patient cohort demonstrated low anxiety levels prior to CT. Relaxation music in CCTA, PVCT and CCS does not reduce heart rate or IV metoprolol use. Patients showed low levels of anxiety indicating that anxiolytics may not have a significant role in lowering heart rate. Music can be used in cardiac CT to improve patient experience. • Relaxation music does not reduce heart rate in cardiac CT • Relaxation music does not reduce beta-blocker use in cardiac CT • Relaxation music has no effect on cardiac CT image quality • Low levels of anxiety are present in patients prior to cardiac CT • Patients enjoyed the relaxation music and this results in improved patient experience.

  17. Dose-related ethanol intake, Cx43 and Nav1.5 remodeling: Exploring insights of altered ventricular conduction and QRS fragmentation in excessive alcohol users.

    Science.gov (United States)

    Hung, Chung-Lieh; Lai, Yu-Jun; Chi, Po-Ching; Chen, Liang-Chia; Tseng, Ya-Ming; Kuo, Jen-Yuan; Lin, Cheng-I; Chen, Yao-Chang; Lin, Shing-Jong; Yeh, Hung-I

    2018-01-01

    Chronic, excessive ethanol intake has been linked with various electrical instabilities, conduction disturbances, and even sudden cardiac death, but the underlying cause for the latter is insufficiently delineated. We studied surface electrocardiography (ECG) in a community-dwelling cohort with moderate-to-heavy daily alcohol intake (grouped as >90g/day, ≤90g/day, and nonintake). Compared with nonintake, heavier alcohol users showed markedly widened QRS duration and higher prevalence of QRS fragmentation (64.3%, 50.9%, and 33.7%, respectively, χ 2 12.0, both pchronically given a 4% or 6% alcohol diet and showed dose-related slower action potential upstroke, reduced resting membrane potential, and disorganized or decreased intraventricular conduction (all pChronic excessive alcohol ingestion is associated with dose-related phenotypic intraventricular conduction disturbances and QRS fragmentation that can be recapitulated in mice. The mechanisms may involve suppressed gap junction and sodium channel functions, together with enhanced cardiac fibrosis that may contribute to arrhythmogenesis. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. V–V delay interval optimization in CRT using echocardiography compared to QRS width in surface ECG

    Directory of Open Access Journals (Sweden)

    Amr Nawar

    2012-09-01

    Conclusion: Significant correlation appeared to exist during optimization of CRT between VV programming based on the shortest QRS interval at 12-lead ECG pacing and that based on highest LVOT VTI by echocardiography. A combined ECG and echocardiographic approach could be a more convenient solution in performing V–V optimization.

  19. Ivabradine in acute coronary syndromes: Protection beyond heart rate lowering.

    Science.gov (United States)

    Niccoli, Giampaolo; Borovac, Josip Anđelo; Vetrugno, Vincenzo; Camici, Paolo G; Crea, Filippo

    2017-06-01

    Ivabradine is a heart rate reducing agent that exhibits anti-ischemic effects through the inhibition of funny electrical current in the sinus node resulting in heart rate reduction, thus enabling longer diastolic perfusion time, and reduced myocardial oxygen consumption without detrimental changes in arterial blood pressure, coronary vasomotion, and ventricular contractility. The current guideline-based clinical use of Ivabradine is reserved for patients with stable angina pectoris who cannot tolerate or whose symptoms are inadequately controlled with beta blockers. In patients with chronic heart failure and reduced ejection fraction, Ivabradine has demonstrated beneficial effects in improving clinical outcomes when added to conventional therapy. However, the role of Ivabradine in acute coronary syndromes has not been established. Based on the results from some relevant preclinical studies and a limited amount of clinical data that were reported recently, the role of Ivabradine in acute ischemic events warrants further investigation. The aim of this review is to provide an overview of the available literature on the potential role of Ivabradine in the clinical context of acute coronary syndromes. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Features of Heart Rate Variability Capture Regulatory Changes During Kangaroo Care in Preterm Infants.

    Science.gov (United States)

    Kommers, Deedee R; Joshi, Rohan; van Pul, Carola; Atallah, Louis; Feijs, Loe; Oei, Guid; Bambang Oetomo, Sidarto; Andriessen, Peter

    2017-03-01

    To determine whether heart rate variability (HRV) can serve as a surrogate measure to track regulatory changes during kangaroo care, a period of parental coregulation distinct from regulation within the incubator. Nurses annotated the starting and ending times of kangaroo care for 3 months. The pre-kangaroo care, during-kangaroo care, and post-kangaroo care data were retrieved in infants with at least 10 accurately annotated kangaroo care sessions. Eight HRV features (5 in the time domain and 3 in the frequency domain) were used to visually and statistically compare the pre-kangaroo care and during-kangaroo care periods. Two of these features, capturing the percentage of heart rate decelerations and the extent of heart rate decelerations, were newly developed for preterm infants. A total of 191 kangaroo care sessions were investigated in 11 preterm infants. Despite clinically irrelevant changes in vital signs, 6 of the 8 HRV features (SD of normal-to-normal intervals, root mean square of the SD, percentage of consecutive normal-to-normal intervals that differ by >50 ms, SD of heart rate decelerations, high-frequency power, and low-frequency/high-frequency ratio) showed a visible and statistically significant difference (P heart rate decelerations. HRV-based features may be clinically useful for capturing the dynamic changes in autonomic regulation in response to kangaroo care and other changes in environment and state. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Randomized controlled trial of relaxation music to reduce heart rate in patients undergoing cardiac CT

    Energy Technology Data Exchange (ETDEWEB)

    Ng, Ming Yen [University of Toronto, Department of Medical Imaging, Toronto General Hospital, Toronto, ON (Canada); The University of Hong Kong, Queen Mary Hospital, Department of Diagnostic Radiology, Hong Kong (China); Karimzad, Yasser; Menezes, Ravi J.; Wintersperger, Bernd J.; Li, Qin; Forero, Julian; Paul, Narinder S.; Nguyen, Elsie T. [University of Toronto, Department of Medical Imaging, Toronto General Hospital, Toronto, ON (Canada)

    2016-10-15

    To evaluate the heart rate lowering effect of relaxation music in patients undergoing coronary CT angiography (CCTA), pulmonary vein CT (PVCT) and coronary calcium score CT (CCS). Patients were randomised to a control group (i.e. standard of care protocol) or to a relaxation music group (ie. standard of care protocol with music). The groups were compared for heart rate, radiation dose, image quality and dose of IV metoprolol. Both groups completed State-Trait Anxiety Inventory anxiety questionnaires to assess patient experience. One hundred and ninety-seven patients were recruited (61.9 % males); mean age 56y (19-86 y); 127 CCTA, 17 PVCT, 53 CCS. No significant difference in heart rate, radiation dose, image quality, metoprolol dose and anxiety scores. 86 % of patients enjoyed the music. 90 % of patients in the music group expressed a strong preference to have music for future examinations. The patient cohort demonstrated low anxiety levels prior to CT. Relaxation music in CCTA, PVCT and CCS does not reduce heart rate or IV metoprolol use. Patients showed low levels of anxiety indicating that anxiolytics may not have a significant role in lowering heart rate. Music can be used in cardiac CT to improve patient experience. (orig.)

  2. Randomized controlled trial of relaxation music to reduce heart rate in patients undergoing cardiac CT

    International Nuclear Information System (INIS)

    Ng, Ming Yen; Karimzad, Yasser; Menezes, Ravi J.; Wintersperger, Bernd J.; Li, Qin; Forero, Julian; Paul, Narinder S.; Nguyen, Elsie T.

    2016-01-01

    To evaluate the heart rate lowering effect of relaxation music in patients undergoing coronary CT angiography (CCTA), pulmonary vein CT (PVCT) and coronary calcium score CT (CCS). Patients were randomised to a control group (i.e. standard of care protocol) or to a relaxation music group (ie. standard of care protocol with music). The groups were compared for heart rate, radiation dose, image quality and dose of IV metoprolol. Both groups completed State-Trait Anxiety Inventory anxiety questionnaires to assess patient experience. One hundred and ninety-seven patients were recruited (61.9 % males); mean age 56y (19-86 y); 127 CCTA, 17 PVCT, 53 CCS. No significant difference in heart rate, radiation dose, image quality, metoprolol dose and anxiety scores. 86 % of patients enjoyed the music. 90 % of patients in the music group expressed a strong preference to have music for future examinations. The patient cohort demonstrated low anxiety levels prior to CT. Relaxation music in CCTA, PVCT and CCS does not reduce heart rate or IV metoprolol use. Patients showed low levels of anxiety indicating that anxiolytics may not have a significant role in lowering heart rate. Music can be used in cardiac CT to improve patient experience. (orig.)

  3. Influence of peak exercise heart rate on normal thallium-201 myocardial clearance

    International Nuclear Information System (INIS)

    Kaul, S.; Chesler, D.A.; Pohost, G.M.; Strauss, H.W.; Okada, R.D.; Boucher, C.A.

    1986-01-01

    Measurement of myocardial clearance rates between initial and delayed images is a major justification for adding computer quantification to the interpretation of exercise 201 TI images. To clarify the range of normal thallium clearance and its relationship to the level of exercise achieved, exercise thallium images in 89 normal subjects were analyzed: 45 asymptomatic subjects with less than 1% probability of coronary artery disease (CAD) (Group I), and 44 patients with chest pain found to have no significant CAD on angiography (Group II). Mean initial regional thallium uptake was similar in the two groups, but myocardial thallium clearance (mean +/- 1 s.d.) was slower in Group II, expressed as a longer half-life in the myocardium (8.2 +/- 7.6 hr compared with 3.4 +/- 0.7 hr p less than 0.001). Analysis of variance using ten clinical and exercise variables as covariates showed that the slower clearance in Group II was related to a lower peak exercise heart rate (HR) (154 +/- 27 compared with 183 +/- 11, respectively, p less than 0.001). By linear regression analysis, a decrease in peak HR of 1 beat/min was associated with a slower thallium clearance (longer half-life) of 0.05 hr. Using this formula, the clearance value in each patient was then corrected for peak exercise heart rate by decreasing measured clearance by 0.05 hr multiplied by the amount peak exercise heart rate which was below 183 (the mean value in Group I). There were no differences in the corrected clearance between the two groups. We conclude that thallium myocardial clearance after exercise is related in part to factors other than the presence of CAD, being slower when peak exercise HR is lower. Therefore, thallium clearance rates alone uncorrected for peak exercise heart rate should be used with caution when diagnosing CAD

  4. Quantifying the Interactions between Maternal and Fetal Heart Rates by Transfer Entropy.

    Directory of Open Access Journals (Sweden)

    Faezeh Marzbanrad

    Full Text Available Evidence of the short term relationship between maternal and fetal heart rates has been found in previous studies. However there is still limited knowledge about underlying mechanisms and patterns of the coupling throughout gestation. In this study, Transfer Entropy (TE was used to quantify directed interactions between maternal and fetal heart rates at various time delays and gestational ages. Experimental results using maternal and fetal electrocardiograms showed significant coupling for 63 out of 65 fetuses, by statistically validating against surrogate pairs. Analysis of TE showed a decrease in transfer of information from fetus to the mother with gestational age, alongside the maturation of the fetus. On the other hand, maternal to fetal TE was significantly greater in mid (26-31 weeks and late (32-41 weeks gestation compared to early (16-25 weeks gestation (Mann Whitney Wilcoxon (MWW p<0.05. TE further increased from mid to late, for the fetuses with RMSSD of fetal heart rate being larger than 4 msec in the late gestation. This difference was not observed for the fetuses with smaller RMSSD, which could be associated with the quiet sleep state. Delay in the information transfer from mother to fetus significantly decreased (p = 0.03 from mid to late gestation, implying a decrease in fetal response time. These changes occur concomitant with the maturation of the fetal sensory and autonomic nervous systems with advancing gestational age. The effect of maternal respiratory rate derived from maternal ECG was also investigated and no significant relationship was found between breathing rate and TE at any lag. In conclusion, the application of TE with delays revealed detailed information on the fetal-maternal heart rate coupling strength and latency throughout gestation, which could provide novel clinical markers of fetal development and well-being.

  5. Temporal discounting and heart rate reactivity to stress.

    Science.gov (United States)

    Diller, James W; Patros, Connor H G; Prentice, Paula R

    2011-07-01

    Temporal discounting is the reduction of the value of a reinforcer as a function of increasing delay to its presentation. Impulsive individuals discount delayed consequences more rapidly than self-controlled individuals, and impulsivity has been related to substance abuse, gambling, and other problem behaviors. A growing body of literature has identified biological correlates of impulsivity, though little research to date has examined relations between delay discounting and markers of poor health (e.g., cardiovascular reactivity to stress). We evaluated the relation between one aspect of impulsivity, measured using a computerized temporal discounting task, and heart rate reactivity, measured as a change in heart rate from rest during a serial subtraction task. A linear regression showed that individuals who were more reactive to stress responded more impulsively (i.e., discounted delayed reinforcers more rapidly). When results were stratified by gender, the effect was observed for females, but not for males. This finding supports previous research on gender differences in cardiovascular reactivity and suggests that this type of reactivity may be an important correlate of impulsive behavior. Copyright © 2011 Elsevier B.V. All rights reserved.

  6. Heart rate variability | Lutfi | Sudan Journal of Medical Sciences

    African Journals Online (AJOL)

    An important outcome of such analysis is heart rate variability (HRV), which is widely accepted to have prognostic significance in patients with cardiovascular diseases especially after acute myocardial infarction. This is because HRV represents one of the most helpful markers of autonomic balance and hence can predict ...

  7. Improved detection of congestive heart failure via probabilistic symbolic pattern recognition and heart rate variability metrics.

    Science.gov (United States)

    Mahajan, Ruhi; Viangteeravat, Teeradache; Akbilgic, Oguz

    2017-12-01

    A timely diagnosis of congestive heart failure (CHF) is crucial to evade a life-threatening event. This paper presents a novel probabilistic symbol pattern recognition (PSPR) approach to detect CHF in subjects from their cardiac interbeat (R-R) intervals. PSPR discretizes each continuous R-R interval time series by mapping them onto an eight-symbol alphabet and then models the pattern transition behavior in the symbolic representation of the series. The PSPR-based analysis of the discretized series from 107 subjects (69 normal and 38 CHF subjects) yielded discernible features to distinguish normal subjects and subjects with CHF. In addition to PSPR features, we also extracted features using the time-domain heart rate variability measures such as average and standard deviation of R-R intervals. An ensemble of bagged decision trees was used to classify two groups resulting in a five-fold cross-validation accuracy, specificity, and sensitivity of 98.1%, 100%, and 94.7%, respectively. However, a 20% holdout validation yielded an accuracy, specificity, and sensitivity of 99.5%, 100%, and 98.57%, respectively. Results from this study suggest that features obtained with the combination of PSPR and long-term heart rate variability measures can be used in developing automated CHF diagnosis tools. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Effects and after-effects of chewing gum on vigilance, heart rate, EEG and mood.

    Science.gov (United States)

    Allen, Andrew P; Jacob, Tim J C; Smith, Andrew P

    2014-06-22

    Research has shown that chewing gum improves attention, although the mechanism for this effect remains unclear. This study investigated the effects and after-effects of chewing gum on vigilance, mood, heart rate and EEG. Participants completed a vigilance task four times; at baseline, with or without chewing gum, and twice post-chewing. EEG alpha and beta power at left frontal and temporal lobes, subjective mood and heart rate were assessed. Chewing gum shortened reaction time and increased the rate of hits, although hits fell during the second post-chewing task. Chewing gum heightened heart rate, but only during chewing. Gum also increased beta power at F7 and T3 immediately post-chewing, but not following the post-chewing tasks. The findings show that chewing gum affects several different indicators of alertness. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. Identification of heart rate-associated loci and their effects on cardiac conduction and rhythm disorders

    NARCIS (Netherlands)

    den Hoed, M.A.H.; Eijgelsheim, M.; Esko, T.; Brundel, B.J.; Peal, D.S.; Evans, D.M.; Nolte, I.M.; Segrè, A.V.; Holm, H.; Handsaker, R.E.; Westra, H.J.; Johnson, T.; Isaacs, A.; Yang, L.; Lundby, A.; Zhao, J.H.; Kim, Y.J.; Go, M.J.; Almgren, P.; Bochud, M.; Boucher, G.; Cornelis, M.C.; Gudbjartsson, D.F.; Hadley, D.; van der Harst, P.; Hayward, C.; den Heijer, M.; Igl, W.; Jackson, A.U.; Kutalik, Z.; Luan, J.; Kemp, J.P.; Kristiansson, K.; Ladenvall, C.; Lorentzon, M.; Montasser, M.E.; Njajou, O.T.; O'Reilly, P.F.; Padmanabhan, S.; St Pourcain, B.; Rankinen, T.; Salo, P.; Tanaka, T.; Timpson, N.J.; Vitart, V.; Waite, L.; Wheeler, W.; Zhang, W.; Draisma, H.H.M.; Feitosa, M.F.; Kerr, K.F.; Lind, P.A.; Mihailov, E.; Onland-Moret, N.C.; Song, C.; Weedon, M.N.; Xie, W.; Yengo, L.; Absher, D.; Albert, C.M.; Alonso, A.; Arking, D.E.; de Bakker, P.I.; Balkau, B.; Barlassina, C.; Benaglio, P.; Bis, J.C.; Bouatia-Naji, N.; Brage, S.; Chanock, S.J.; Chines, P.S.; Chung, M.; Darbar, D.; Dina, C.; Dörr, M.; Elliott, P.; Felix, S.B.; Fischer, K.; Fuchsberger, C.; de Geus, E.J.C.; Goyette, P.; Gudnason, V.; Harris, T.B.; Hartikainen, A.L.; Havulinna, A.S.; Heckbert, S.R.; Hicks, A.A.; Hofman, A.; Holewijn, S.; Hoogstra-Berends, F.; Hottenga, J.J.; Jensen, M.K.; Johansson, A.; Junttila, J.; Kääb, S.; Kanon, B.; Ketkar, S.; Khaw, K.T.; Knowles, J.W.; Kooner, A.S.; Kors, J.A.; Kumari, M.; Milani, L.; Laiho, P.; Lakatta, E.G.; Langenberg, C.; Leusink, M.; Liu, Y.; Luben, R.N.; Lunetta, K.L.; Lynch, S.N.; Markus, M.R.; Marques-Vidal, P.; Mateo Leach, I.; McArdle, W.L.; McCarroll, S.A.; Medland, S.E.; Miller, K.A.; Montgomery, G.W.; Morrison, A.C.; Müller-Nurasyid, M.; Navarro, P.; Nelis, M.; O'Connell, J.R.; O'Donnell, C.J.; Ong, K.K.; Newman, A.B.; Peters, A.; Polasek, O.; Pouta, A.; Pramstaller, P.P.; Psaty, B.M.; Rao, D.C.; Ring, S.M.; Rossin, E.J.; Rudan, D.; Sanna, S.; Scott, R.A.; Sehmi, J.S.; Sharp, S.; Shin, J.T.; Singleton, A.B.; Smith, A.V.; Soranzo, N.; Spector, T.D.; Stewart, C.; Stringham, H.M.; Tarasov, K.V.; Uitterlinden, A.G.; Vandenput, L.; Hwang, S.J.; Whitfield, J.B.; Wijmenga, C.; Wild, S.H.; Willemsen, G.; Wilson, J.F.; Witteman, J.C.; Wong, A.; Wong, Q.; Jamshidi, Y.; Zitting, P.; Boer, J.M.; Boomsma, D.I.; Borecki, I.B.; van Duijn, C.M.; Ekelund, U.; Forouhi, N.G.; Froguel, P.; Hingorani, A.D.; Ingelsson, E.; Kivimaki, M.; Kronmal, R.A.; Kuh, D; Lind, L.; Martin, N.G.; Oostra, B.A.; Pedersen, N.L.; Quertermous, T.; Rotter, J.I.; van der Schouw, Y.T.; Verschuren, W.M.; Walker, M.; Albanes, D.; Arnar, D.O.; Assimes, T.L.; Bandinelli, S.; Boehnke, M.; de Boer, R.A.; Bouchard, C.; Caulfield, W.L.; Chambers, J.C.; Curhan, G.; Cusi, D.; Eriksson, J.; Ferrucci, L.; van Gilst, W.H.; Glorioso, N.; de Graaf, J.; Groop, L.; Gyllensten, U.; Hsueh, W.C.; Hu, F.B.; Huikuri, H.V.; Hunter, D.J.; Iribarren, C.; Isomaa, B.; Järvelin, M.R.; Jula, A.; Kähönen, M.; Kiemeney, L.A.; van der Klauw, M.M.; Kooner, J.S.; Kraft, P.; Iacoviello, L.; Lehtimäki, T.; Lokki, M.L.; Mitchell, B.D.; Navis, G.; Nieminen, M.S.; Ohlsson, C.; Poulter, N.R.; Qi, L.; Raitakari, O.T.; Rimm, E.B.; Rioux, J.D.; Rizzi, F.; Rudan, I.; Salomaa, V.; Sever, P.S.; Shields, D.C.; Shuldiner, A.R.; Sinisalo, J.; Stanton, A.V.; Stolk, R.P.; Strachan, D.P.; Tardif, J.C.; Thorsteinsdottir, U.; Tuomilehto, J.; van Veldhuisen, D.J.; Virtamo, J.; Viikari, J.; Vollenweider, P.; Waeber, G.; Widen, E.; Cho, Y.S.; Olsen, J.V.; Visscher, P.M.; Willer, C.J.; Franke, L; Erdmann, J.; Thompson, J.R.; Pfeufer, A.; Sotoodehnia, N.; Newton-Cheh, C.; Ellinor, P.T.; Stricker, B.H.C.; Metspalu, A.; Perola, M.; Beckmann, J.S.; Smith, G.D.; Stefansson, K.; Wareham, N.J.; Munroe, P.B.; Sibon, O.C.M.; Milan, D.J.; Snieder, H.; Samani, N.J.; Loos, R.J.

    2013-01-01

    Elevated resting heart rate is associated with greater risk of cardiovascular disease and mortality. In a 2-stage meta-analysis of genome-wide association studies in up to 181,171 individuals, we identified 14 new loci associated with heart rate and confirmed associations with all 7 previously

  10. Relative influence of age, resting heart rate and sedentary life style in short-term analysis of heart rate variability

    Directory of Open Access Journals (Sweden)

    E.R. Migliaro

    2001-04-01

    Full Text Available In order to assess the relative influence of age, resting heart rate (HR and sedentary life style, heart rate variability (HRV was studied in two different groups. The young group (YG consisted of 9 sedentary subjects aged 15 to 20 years (YG-S and of 9 nonsedentary volunteers (YG-NS also aged 15 to 20. The elderly sedentary group (ESG consisted of 16 sedentary subjects aged 39 to 82 years. HRV was assessed using a short-term procedure (5 min. R-R variability was calculated in the time-domain by means of the root mean square successive differences. Frequency-domain HRV was evaluated by power spectrum analysis considering high frequency and low frequency bands. In the YG the effort tolerance was ranked in a bicycle stress test. HR was similar for both groups while ESG showed a reduced HRV compared with YG. Within each group, HRV displayed a negative correlation with HR. Although YG-NS had better effort tolerance than YG-S, their HR and HRV were not significantly different. We conclude that HRV is reduced with increasing HR or age, regardless of life style. The results obtained in our short-term study agree with others of longer duration by showing that age and HR are the main determinants of HRV. Our results do not support the idea that changes in HRV are related to regular physical activity.

  11. Relative influence of age, resting heart rate and sedentary life style in short-term analysis of heart rate variability.

    Science.gov (United States)

    Migliaro, E R; Contreras, P; Bech, S; Etxagibel, A; Castro, M; Ricca, R; Vicente, K

    2001-04-01

    In order to assess the relative influence of age, resting heart rate (HR) and sedentary life style, heart rate variability (HRV) was studied in two different groups. The young group (YG) consisted of 9 sedentary subjects aged 15 to 20 years (YG-S) and of 9 nonsedentary volunteers (YG-NS) also aged 15 to 20. The elderly sedentary group (ESG) consisted of 16 sedentary subjects aged 39 to 82 years. HRV was assessed using a short-term procedure (5 min). R-R variability was calculated in the time-domain by means of the root mean square successive differences. Frequency-domain HRV was evaluated by power spectrum analysis considering high frequency and low frequency bands. In the YG the effort tolerance was ranked in a bicycle stress test. HR was similar for both groups while ESG showed a reduced HRV compared with YG. Within each group, HRV displayed a negative correlation with HR. Although YG-NS had better effort tolerance than YG-S, their HR and HRV were not significantly different. We conclude that HRV is reduced with increasing HR or age, regardless of life style. The results obtained in our short-term study agree with others of longer duration by showing that age and HR are the main determinants of HRV. Our results do not support the idea that changes in HRV are related to regular physical activity.

  12. Multidetector-row computed tomography coronary angiography. Optimization of image reconstruction phase according to the heart rate

    International Nuclear Information System (INIS)

    Nagatani, Yukihiro; Takahashi, Masashi; Takazakura, Ryutaro; Nitta, Norihisa; Murata, Kiyoshi; Ushio, Noritoshi; Matsuo, Shinro; Yamamoto, Takashi; Horie, Minoru

    2007-01-01

    The purpose of this study was to optimize the image reconstruction phase of multidetector-row computed tomography (MDCT) coronary angiography according to the heart rate is crucial. Scan data were reconstructed for 10 different phases in 58 sequential patients who under went 8-row cardiac MDCT. The obtained images were scored and compared in terms of motion artifacts and visibility of the vessels, and moreover, electrocardiogram (ECG) record-based evaluations were added for clarification of the temporal relationships among these 10 phases. In the cases with lower heart rates ( 65 beats/mm), they were obtained in the late systolic period. As the heart rate increased, the optimal image reconstruction phase changed from mid diastole to late systole. However, it is recommended to try to decrease the heart rate of patients before data acquisition. (author)

  13. Facial electromyogram and heart-rate correlates of a paradoxical attitude change to antinuclear war information

    International Nuclear Information System (INIS)

    Vigne, J.J.; Dale, J.A.; Klions, H.L.

    1988-01-01

    The effects of film images versus film descriptions of the effects of nuclear explosions (versus a no-film control) on corrugator muscle tension, heart rate, attitude and mood were investigated. The last 5 min. of the images were associated with more corrugator tension for that condition when compared to the last 5 min. of the description condition. The groups did not differ in heart rate but women in both groups showed an increase in heart rate whereas men in both groups showed a decrease in heart rate. Film groups did not differ in their significant increases in anxiety, hostility, and depression on the Multiple Adjective Affect Checklist. On the pretest there was no significant correlation between scores on Betts' Questionnaire Upon Mental Imagery and scores on Goldenring and Doctor's index of concern for nuclear war. The vivid-image film group showed a decrease in concern for nuclear war when compared to the descriptive film group and the no-film control

  14. The antiarrhythmic effect of vagal stimulation after acute coronary occlusion: Role of the heart rate.

    Science.gov (United States)

    Manati, Waheed; Pineau, Julien; Doñate Puertas, Rosa; Morel, Elodie; Quadiri, Timour; Bui-Xuan, Bernard; Chevalier, Philippe

    2018-01-03

    Strong evidence suggests a causal link between autonomic disturbances and ventricular arrhythmias. However, the mechanisms underlying the antiarrhythmic effect of vagal stimulation are poorly understood. The vagal antiarrhythmic effect might be modulated by a decrease in heart rate. the proximal anterior interventricular artery was occluded in 16 pigs by clamping under general anaesthesia. Group 1: heart rates remained spontaneous (n = 6; 12 occlusions); Group 2: heart rates were fixed at 190 beats per minute (bpm) with atrial electrical stimulation (n = 10; 20 occlusions). Each pig received two occlusions, 30 min apart, one without and one with vagal stimulation (10 Hz, 2 ms, 5-20 mA). The antiarrhythmic effect of vagal activation was defined as the time to the appearance of ventricular fibrillation (VF) after occlusion. In Group 1, vagal stimulation triggered a significant decrease in basal heart rate (132 ± 4 vs. 110 ± 17 bpm, p coronary occlusion (1102 ± 85 vs. 925 ± 41 s, p acute coronary occlusion.

  15. State Anxiety and Nonlinear Dynamics of Heart Rate Variability in Students.

    Science.gov (United States)

    Dimitriev, Dimitriy A; Saperova, Elena V; Dimitriev, Aleksey D

    2016-01-01

    Clinical and experimental research studies have demonstrated that the emotional experience of anxiety impairs heart rate variability (HRV) in humans. The present study investigated whether changes in state anxiety (SA) can also modulate nonlinear dynamics of heart rate. A group of 96 students volunteered to participate in the study. For each student, two 5-minute recordings of beat intervals (RR) were performed: one during a rest period and one just before a university examination, which was assumed to be a real-life stressor. Nonlinear analysis of HRV was performed. The Spielberger's State-Trait Anxiety Inventory was used to assess the level of SA. Before adjusting for heart rate, a Wilcoxon matched pairs test showed significant decreases in Poincaré plot measures, entropy, largest Lyapunov exponent (LLE), and pointwise correlation dimension (PD2), and an increase in the short-term fractal-like scaling exponent of detrended fluctuation analysis (α1) during the exam session, compared with the rest period. A Pearson analysis indicated significant negative correlations between the dynamics of SA and Poincaré plot axes ratio (SD1/SD2), and between changes in SA and changes in entropy measures. A strong negative correlation was found between the dynamics of SA and LLE. A significant positive correlation was found between the dynamics of SA and α1. The decreases in Poincaré plot measures (SD1, complex correlation measure), entropy measures, and LLE were still significant after adjusting for heart rate. Corrected α1 was increased during the exam session. As before, the dynamics of adjusted LLE was significantly correlated with the dynamics of SA. The qualitative increase in SA during academic examination was related to the decrease in the complexity and size of the Poincaré plot through a reduction of both the interbeat interval and its variation.

  16. State Anxiety and Nonlinear Dynamics of Heart Rate Variability in Students.

    Directory of Open Access Journals (Sweden)

    Dimitriy A Dimitriev

    Full Text Available Clinical and experimental research studies have demonstrated that the emotional experience of anxiety impairs heart rate variability (HRV in humans. The present study investigated whether changes in state anxiety (SA can also modulate nonlinear dynamics of heart rate.A group of 96 students volunteered to participate in the study. For each student, two 5-minute recordings of beat intervals (RR were performed: one during a rest period and one just before a university examination, which was assumed to be a real-life stressor. Nonlinear analysis of HRV was performed. The Spielberger's State-Trait Anxiety Inventory was used to assess the level of SA.Before adjusting for heart rate, a Wilcoxon matched pairs test showed significant decreases in Poincaré plot measures, entropy, largest Lyapunov exponent (LLE, and pointwise correlation dimension (PD2, and an increase in the short-term fractal-like scaling exponent of detrended fluctuation analysis (α1 during the exam session, compared with the rest period. A Pearson analysis indicated significant negative correlations between the dynamics of SA and Poincaré plot axes ratio (SD1/SD2, and between changes in SA and changes in entropy measures. A strong negative correlation was found between the dynamics of SA and LLE. A significant positive correlation was found between the dynamics of SA and α1. The decreases in Poincaré plot measures (SD1, complex correlation measure, entropy measures, and LLE were still significant after adjusting for heart rate. Corrected α1 was increased during the exam session. As before, the dynamics of adjusted LLE was significantly correlated with the dynamics of SA.The qualitative increase in SA during academic examination was related to the decrease in the complexity and size of the Poincaré plot through a reduction of both the interbeat interval and its variation.

  17. Analysis of the High-Frequency Content in Human QRS Complexes by the Continuous Wavelet Transform: An Automatized Analysis for the Prediction of Sudden Cardiac Death.

    Science.gov (United States)

    García Iglesias, Daniel; Roqueñi Gutiérrez, Nieves; De Cos, Francisco Javier; Calvo, David

    2018-02-12

    Fragmentation and delayed potentials in the QRS signal of patients have been postulated as risk markers for Sudden Cardiac Death (SCD). The analysis of the high-frequency spectral content may be useful for quantification. Forty-two consecutive patients with prior history of SCD or malignant arrhythmias (patients) where compared with 120 healthy individuals (controls). The QRS complexes were extracted with a modified Pan-Tompkins algorithm and processed with the Continuous Wavelet Transform to analyze the high-frequency content (85-130 Hz). Overall, the power of the high-frequency content was higher in patients compared with controls (170.9 vs. 47.3 10³nV²Hz -1 ; p = 0.007), with a prolonged time to reach the maximal power (68.9 vs. 64.8 ms; p = 0.002). An analysis of the signal intensity (instantaneous average of cumulative power), revealed a distinct function between patients and controls. The total intensity was higher in patients compared with controls (137.1 vs. 39 10³nV²Hz -1 s -1 ; p = 0.001) and the time to reach the maximal intensity was also prolonged (88.7 vs. 82.1 ms; p content of the QRS complexes was distinct between patients at risk of SCD and healthy controls. The wavelet transform is an efficient tool for spectral analysis of the QRS complexes that may contribute to stratification of risk.

  18. The fall in the rate of death from heart diseases

    International Nuclear Information System (INIS)

    Bemski, G.

    1983-01-01

    A self limiting interaction between heart disease producing factors and genetic factors is postulated. Such an interaction could be responsable for the fall in rate of death from ischemic disease observed in the United States. (Author) [pt

  19. Adaptación de la forma abreviada del “cuestionario de recursos y estrés (QRS-F, 1983, para padres de personas con autismo / Adaptation of the been brief form of the the

    Directory of Open Access Journals (Sweden)

    Soto Calderón, Ronald

    2008-04-01

    Full Text Available Resumen: Medir el estrés en padres de personas con discapacidad ha sido una tarea muy difícil. En 1974, Holroyd desarrollo el “Cuestionario de recursos y estrés (QRS (de 289 ítemes, para solventar esta necesidad. No obstante, por su longitud y dificultad de análisis psicométrico, se ha dificultado su empleo en diferentes estudios. Friedrich y otros, en 1983, realizaron un estudio de los 289 ítemes del cuestionario QRS y obtuvieron la “Forma abreviada del Cuestionario de Recursos y Estrés (QRS-F”, la cual consta de 52 ítemes representativos de la prueba original. El análisis de factores aplicado tuvo como resultado que emergieran cuatro factores, a saber: Problemas de los padres y la familia, Pesimismo, Características del niño e incapacidad física. En el presente estudio se hizo la adaptación del QRS-F para padres de personas con Autismo en nuestro país.Abstract: To measure stress in parents of people with disability has been a very difficult task. To resolve this necessity, in 1974, Holroyd develop the Questionnaire of Resources and Stress (QRS (of 289 items. However, by its length and difficulty of psychometric analysis, its use in different studies has become difficult. Friedrich and others, in 1983, made a study of the 289 items of the questionnaire QRS and obtained the "been brief Form of the Questionnaire of Resources and Stress (QRS-F", which consists of 52 items representative of the original test. The analysis of factors applied had as result that emerged four factors, that is to say: Problems of the parents and the family, Pessimism, Characteristics of the boy and physical incapacity. In the present study the adaptation was made of the QRS-F for parents of people with Autism in our country.

  20. [Heart rate variability and physical exercise. Current status].

    Science.gov (United States)

    Hottenrott, Kuno; Hoos, Olaf; Esperer, Hans Dieter

    2006-09-01

    Heart rate variability (HRV) has long been used in risk stratification for sudden cardiac death and diabetic autonomic neuropathy. In recent years, both time and frequency domain indices of HRV also gained increasing interest in sports and training sciences. In these fields, HRV is currently used for the noninvasive assessment of autonomic changes associated with short-term and long-term endurance exercise training in both leisure sports activity and high-performance training. Furthermore, HRV is being investigated as a diagnostic marker of overreaching and overtraining.A large body of evidence shows that, in healthy subjects and cardiovascular patients of all ages (up to an age of 70 years), regular aerobic training usually results in a significant improvement of overall as well as instantaneous HRV. These changes, which are accompanied by significant reductions in heart rates both at rest and during submaximal exercise, reflect an increase in autonomic efferent activity and a shift in favor of enhanced vagal modulation of the cardiac rhythm. Regular aerobic training of moderate volume and intensity over a minimum period of 3 months seems to be necessary to ensure these effects, which might be associated with a prognostic benefit regarding overall mortality.At present, available data does not allow for final conclusions with respect to the usefulness of traditional HRV indices in assessing an individual's exercise performance and monitoring training load. The discrepant results published so far are due to several factors including insufficient study size and design, and different HRV methods. Large-sized and prospectively designed studies are necessary for clarification. It also remains to be seen, whether the traditional HRV indices prove useful in the diagnosis of overreaching and overtraining. Preliminary results, though promising, need to be confirmed in larger cohorts.A basic problem in HRV analysis is nonstationarity of the heart rate signal, which holds

  1. Higher Precision of Heart Rate Compared with VO2 to Predict Exercise Intensity in Endurance-Trained Runners.

    Science.gov (United States)

    Reis, Victor M; den Tillaar, Roland Van; Marques, Mario C

    2011-01-01

    The aim of the present study was to assess the precision of oxygen uptake with heart rate regression during track running in highly-trained runners. Twelve national and international level male long-distance road runners (age 30.7 ± 5.5 yrs, height 1.71 ± 0.04 m and mass 61.2 ± 5.8 kg) with a personal best on the half marathon of 62 min 37 s ± 1 min 22 s participated in the study. Each participant performed, in an all-weather synthetic track five, six min bouts at constant velocity with each bout at an increased running velocity. The starting velocity was 3.33 m·s(-1) with a 0.56 m·s(-1) increase on each subsequent bout. VO2 and heart rate were measured during the runs and blood lactate was assessed immediately after each run. Mean peak VO2 and mean peak heart rate were, respectively, 76.2 ± 9.7 mL·kg(-1)·min(-1) and 181 ± 13 beats·min(-1). The linearity of the regressions between heart rate, running velocity and VO2 were all very high (r > 0.99) with small standard errors of regression (i.e. Sy.x at the velocity associated with the 2 and 4 mmol·L(-1) lactate thresholds). The strong relationships between heart rate, running velocity and VO2 found in this study show that, in highly trained runners, it is possible to have heart rate as an accurate indicator of energy demand and of the running speed. Therefore, in this subject cohort it may be unnecessary to use VO2 to track changes in the subjects' running economy during training periods. Key pointsHeart rate is used in the control of exercise intensity in endurance sports.However, few studies have quantified the precision of its relationship with oxygen uptake in highly trained runners.We evaluated twelve elite half-marathon runners during track running at various intensities and established three regressions: oxygen uptake / heart rate; heart rate / running velocity and oxygen uptake / running velocity.The three regressions presented, respectively, imprecision of 4,2%, 2,75% and 4,5% at the velocity

  2. Heart Rate Variability and Drawing Impairment in Hypoxemic COPD

    Science.gov (United States)

    Incalzi, Raffaele Antonelli; Corsonello, Andrea; Trojano, Luigi; Pedone, Claudio; Acanfora, Domenico; Spada, Aldo; D'Addio, Gianni; Maestri, Roberto; Rengo, Franco; Rengo, Giuseppe

    2009-01-01

    We studied 54 patients with hypoxemic chronic obstructive pulmonary disease (COPD). The Mini Mental State Examination and the Mental Deterioration Battery were used for neuropsychological assessment. Heart rate variability (HRV) was assessed based on 24-h Holter ECG recording. Mann-Whitney test was used to compare HRV parameters of patients…

  3. Complete atrio-ventricular septal defect and Wolf-Parkinson-White syndrome

    Directory of Open Access Journals (Sweden)

    Gudrun Björkhem

    2006-09-01

    Full Text Available A full term female infant was born after 41 weeks of gestation, with a birth weight of 3815g and normal Apgar scores (9-10-10. Immediately after birth tachycardia was noted. An electrocardiogram (ECG showed a heart rate of 300 beats per minute (bpm and narrow QRS complexes. The newborn was clinically stable. She was admitted to the neonatal intensive care unite and an intravenous line was inserted for treatment with Adenosine. While preparing for Adenosine infusion her heart rate spontaneously decreased. Her ECG at presentation with normal heart rate is shown in figure1a. On auscultation, a soft systolic murmur was heard.

  4. Variation in heart rate during submaximal exercise: Implications for monitoring training : Implications for monitoring training

    NARCIS (Netherlands)

    Lamberts, R.P.; Lemmink, K.A.P.M.; Durandt, J.J.; Lambert, M.I.

    2004-01-01

    A change in heart rate at a controlled submaximal exercise intensity is used as a marker of training status. However, the standard error of measurement has not been studied systematically, and therefore a change in heart rate, which can be considered relevant, has not been determined. Forty-four

  5. Ventricular fibrillation occurring after atrioventricular node ablation despite minimal difference between pre- and post-ablation heart rates.

    Science.gov (United States)

    Squara, F; Theodore, G; Scarlatti, D; Ferrari, E

    2017-02-01

    We report the case of an 82-year-old man presenting with ventricular fibrillation (VF) occurring acutely after atrioventricular node (AVN) ablation. This patient had severe valvular cardiomyopathy, chronic atrial fibrillation (AF), and underwent prior to the AVN ablation a biventricular implantable cardiac defibrillator positioning. The VF was successfully cardioverted with one external electrical shock. What makes this presentation original is that the pre-ablation spontaneous heart rate in AF was slow (84 bpm), and that VF occurred after ablation despite a minimal heart rate drop of only 14 bpm. VF is the most feared complication of AVN ablation, but it had previously only been described in case of acute heart rate drop after ablation of at least 30 bpm (and more frequently>50 bpm). This case report highlights the fact that VF may occur after AVN ablation regardless of the heart rate drop, rendering temporary fast ventricular pacing mandatory whatever the pre-ablation heart rate. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  6. Heart rate and time-motion analyses in top junior players during basketball matches

    Directory of Open Access Journals (Sweden)

    Karel Hůlka

    2013-09-01

    Full Text Available BACKGROUND: Basketball performance can be classified as an intermittent physical activity due to the changing situational game conditions and the number of intervening variables. It is necessary to have detailed knowledge about the performance of basketball players during a match as a background for more specific planning of the training process. OBJECTIVE: The aim of this study was to analyse the indicators of internal and external load of basketball player’s performance during a match of U18 top men basketball players as a background for the planning of specific training processes. METHODS: Thirty-two Czech top junior basketball players (male, aged 16.88 ± 0.72 years participated in this research. The heart rate was recorded and time-motion analysis was conducted during six warm-up matches. RESULTS: The average heart rate was measured to be 167.47 ± 13.01 beats • min.–1, which corresponded to 85.06 ± 6.40% of peak heart rate. The percentages of the total time spent over and under 85% were 63.12% and 36.88%, respectively. Average distance covered was measured to be 5,880.91 ± 831.01 meters. The average work : rest ratio was 1 : 7.95 ± 1.83, ranging from 1 : 4.80 to 1 : 10.92. CONCLUSIONS: The results from these matches suggest that the exercise intensity and sprint activity observed during junior basketball are dependent on the player's position and partly on the level of the performance. The heart rate during a match was not dependent on the positions, however, time-motion analysis revealed significant differences between three basketball positions during a match. The combination of heart rate and time-motion analysis is recommended.

  7. Atenolol Is Associated with Lower Day of Surgery Heart Rate as compared to Long and Short-acting Metoprolol

    Science.gov (United States)

    Schonberger, Robert B.; Brandt, Cynthia; Feinleib, Jessica; Dai, Feng; Burg, Matthew M.

    2012-01-01

    Objectives We analyzed the association between outpatient beta-blocker type and day-of-surgery heart rate in ambulatory surgical patients. We further investigated whether differences in day of surgery heart rate between atenolol and metoprolol could be explained by once-daily versus twice-daily dosing regimens. Design Retrospective observational study. Setting VA Hospital Participants Ambulatory surgical patients on chronic atenolol or metoprolol. Interventions None. Measurements and Main Results Using a propensity-score matched cohort, we compared day of surgery heart rates of patients prescribed atenolol versus metoprolol. We then differentiated between once-daily and twice-daily metoprolol formulations and compared day of surgery heart rates within a general linear model. Day of surgery heart rates in patients prescribed atenolol vs. any metoprolol formulation were slower by a mean of 5.1 beats/min (66.6 vs. 71.7; 95% CI of difference 1.9 to 8.3, p=0.002), a difference that was not observed in preoperative primary care visits. The general linear model demonstrated that patients prescribed atenolol (typically QD dosing) had a mean day of surgery heart rate 5.6 beats/min lower compared to patients prescribed once-daily metoprolol succinate (68.9 vs. 74.5; 95% CI of difference: −8.6 to −2.6, p<0.001) and 3.8 beats/minute lower compared to patients prescribed twice-daily metoprolol tartrate (68.9 vs. 72.7; 95% CI of difference: −6.1 to −1.6, p<0.001). Day of surgery heart rates were similar between different formulations of metoprolol (95% CI of difference: −1.0 to +4.6, p=0.22). Conclusions Atenolol is associated with lower day of surgery heart rate vs. metoprolol. The heart rate difference is specific to the day of surgery and is not explained by once-daily versus twice-daily dosing regimens. PMID:22889605

  8. Longitudinal Associations of Leptin and Adiponectin with Heart Rate Variability in Children

    Directory of Open Access Journals (Sweden)

    Roos Van De Wielle

    2017-07-01

    Full Text Available For early prevention of cardiovascular disease, early detection and risk factor insights are necessary. The autonomic balance reflects cardiovascular risk and can be measured by heart rate variability (HRV. Therefore, our purpose is to examine associations between HRV and the energy-related biomarkers leptin and adiponectin in children. Participants of this study were Belgian children recruited for the longitudinal ChiBS study (year 2010–2012. HRV was measured and fasting blood samples were taken in 249 children at baseline (4.4–11.0 y and 223 children at follow-up (6.7–12.2 y. Cross-sectional and longitudinal linear regression analyses were separated by sex and adjusted for age, socio-economic status, body fat%, negative emotions, puberty, and mean heart rate. Leptin was a negative cross-sectional and longitudinal predictor of parasympathetic activity in boys; while leptin in girls was cross-sectionally associated with higher LF and LF/HF suggesting sympathetic predominance. Adiponectin was a negative cross-sectional and longitudinal predictor of parasympathetic activity in boys; but when adjusting for mean heart rate, this effect disappeared and adiponectin was a positive cross-sectional and longitudinal predictor of parasympathetic activity in girls. These results stress the importance of considering sex differences and adjustment for heart rate in testing HRV predictors. Leptin seemed disadvantageous for the autonomic balance, while adiponectin seemed advantageous for the autonomic balance in girls only. More research is needed to see whether leptin and adiponectin are interesting in cardiovascular screening/prevention or in determining the cardiovascular gain during weight loss follow-up.

  9. Musical Auditory Stimulation Influences Heart Rate Autonomic Responses to Endodontic Treatment

    Directory of Open Access Journals (Sweden)

    Milana Drumond Ramos Santana

    2017-01-01

    Full Text Available We aimed to evaluate the acute effect of musical auditory stimulation on heart rate autonomic regulation during endodontic treatment. The study included 50 subjects from either gender between 18 and 40 years old, diagnosed with irreversible pulpitis or pulp necrosis of the upper front teeth and endodontic treatment indication. HRV was recorded 10 minutes before (T1, during (T2, and immediately (T3 and T4 after endodontic treatment. The volunteers were randomly divided into two equal groups: exposed to music (during T2, T3, and T4 or not. We found no difference regarding salivary cortisol and anxiety score. In the group with musical stimulation heart rate decreased in T3 compared to T1 and mean RR interval increased in T2 and T3 compared to T1. SDNN and TINN indices decreased in T3 compared to T4, the RMSSD and SD1 increased in T4 compared to T1, the SD2 increased compared to T3, and LF (low frequency band increased in T4 compared to T1 and T3. In the control group, only RMSSD and SD1 increased in T3 compared to T1. Musical auditory stimulation enhanced heart rate autonomic modulation during endodontic treatment.

  10. The heart rate response to nintendo wii boxing in young adults.

    Science.gov (United States)

    Bosch, Pamela R; Poloni, Joseph; Thornton, Andrew; Lynskey, James V

    2012-06-01

    To determine if 30 minutes of Nintendo Wii Sports boxing provides cardiorespiratory benefits and contributes to the daily exercise recommendations for healthy young adults. Twenty healthy 23- to 27-year-olds participated in two sessions to measure maximum heart rate (HR(max)) via a treadmill test and heart rate (HR) response to 30 minutes of Wii Sports boxing. Heart rate in beats per minute (bpm) was measured continuously, and exercise intensity during each minute of play was stratified as a percentage of HR(max). Mixed designs analysis of variance (ANOVA) and Pearson product moment correlations were used to analyze the data. Mean (SD) HR response to boxing was 143 (15) bpm or 77.5% (10.0%) of HR(max). The mean HR response for experienced participants was significantly lower than inexperienced participants, P = .007. The ANOVA revealed a significant interaction between experience and time spent at various intensities, P = .009. Experienced participants spent more time in light to vigorous intensities, inexperienced participants in moderate to very hard intensities. Fitness was not correlated with mean HR response to boxing, P = .49. Thirty minutes of Nintendo Wii Sports boxing provides a moderate to vigorous aerobic response in healthy young adults and can contribute to daily recommendations for physical activity.

  11. Association between resting heart rate and N-terminal pro-brain natriuretic peptide in a community-based population study in Beijing

    Directory of Open Access Journals (Sweden)

    Cao R

    2014-12-01

    Full Text Available Ruihua Cao, Yongyi Bai, Ruyi Xu, Ping Ye Department of Geriatric Cardiology, Chinese PLA General Hospital, Beijing, People’s Republic of China Background: N-terminal pro-brain natriuretic peptide (NT-proBNP is associated with an increased risk of cardiac insufficiency, which possibly leads to heart failure. However, the relationship between resting heart rate and NT-proBNP is unclear.Objective: This study focuses on this relativity between resting heart rate and plasma NT-proBNP levels in a surveyed community-based population.Methods: We evaluated the relativity between resting heart rate and plasma levels of NT-proBNP in 1,567 participants (mean age 61.0 years, range 21–96 years from a community-based population in Beijing, People’s Republic of China.Results: In patients with high resting heart rate (≥75 beats/min, NT-proBNP was higher than in those having low resting heart rate (<75 beats/min. In multiple linear stepwise regression analysis, plasma NT-proBNP was associated with resting heart rate (partial correlation coefficient, 0.82; 95% confidence interval, 0.18–1.51; P=0.011. A subsequent subgroup analysis revealed that the association between resting heart rate and plasma NT-proBNP was strengthened in subjects over 60 years old (partial correlation coefficient 1.28; 95% confidence interval, 0.49–2.36; P=0.031; while the relativity between resting heart rate and plasma NT-proBNP was not emerged in the younger subgroup (<60 years old.Conclusions: Resting heart rate was associated with plasma NT-proBNP in the elderly, which indicated a relationship between resting heart rate and cardiac function damage. Keywords: resting heart rate, N-terminal pro-brain natriuretic peptide, epidemiology, cardiac function, relationship

  12. Effects of Orthostatism and Hemodialysis on Mean Heart Period and Fractal Heart Rate Properties of Chronic Renal Failure Patients.

    Science.gov (United States)

    Echeverría, Juan C; Infante, Oscar; Pérez-Grovas, Héctor; González, Hortensia; José, Marco V; Lerma, Claudia

    2017-11-01

    The aim of this work was to evaluate the short-term fractal index (α 1 ) of heart rate variability (HRV) in chronic renal failure (CRF) patients by identifying the effects of orthostatism and hemodialysis (HD), and by evaluating the correlation between α 1 and the mean RR interval from sinus beats (meanNN). HRV time series were derived from ECG data of 19 CRF patients and 20 age-matched healthy subjects obtained at supine and orthostatic positions (lasting 5 min each). Data from CRF patients were collected before and after HD. α 1 was calculated from each time series and compared by analysis of variance. Pearson's correlations between meanNN and α 1 were calculated using the data from both positions by considering three groups: healthy subjects, CRF before HD and CRF after HD. At supine position, α 1 of CRF patients after HD (1.17 ± 0.30) was larger (P renal disease condition in itself. In conclusion, as in healthy subjects, α 1 of CRF patients correlates with meanNN after HD (indicating a more irregular-like HRV behavior at slower heart rates). This suggests that CRF patients with stable blood pressure preserve a regulatory adaptability despite a shifted setting point of the heart period (i.e., higher heart rate) in comparison with healthy subjects. © 2017 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  13. Job strain and resting heart rate: a cross-sectional study in a Swedish random working sample

    Directory of Open Access Journals (Sweden)

    Peter Eriksson

    2016-03-01

    Full Text Available Abstract Background Numerous studies have reported an association between stressing work conditions and cardiovascular disease. However, more evidence is needed, and the etiological mechanisms are unknown. Elevated resting heart rate has emerged as a possible risk factor for cardiovascular disease, but little is known about the relation to work-related stress. This study therefore investigated the association between job strain, job control, and job demands and resting heart rate. Methods We conducted a cross-sectional survey of randomly selected men and women in Västra Götalandsregionen, Sweden (West county of Sweden (n = 1552. Information about job strain, job demands, job control, heart rate and covariates was collected during the period 2001–2004 as part of the INTERGENE/ADONIX research project. Six different linear regression models were used with adjustments for gender, age, BMI, smoking, education, and physical activity in the fully adjusted model. Job strain was operationalized as the log-transformed ratio of job demands over job control in the statistical analyses. Results No associations were seen between resting heart rate and job demands. Job strain was associated with elevated resting heart rate in the unadjusted model (linear regression coefficient 1.26, 95 % CI 0.14 to 2.38, but not in any of the extended models. Low job control was associated with elevated resting heart rate after adjustments for gender, age, BMI, and smoking (linear regression coefficient −0.18, 95 % CI −0.30 to −0.02. However, there were no significant associations in the fully adjusted model. Conclusions Low job control and job strain, but not job demands, were associated with elevated resting heart rate. However, the observed associations were modest and may be explained by confounding effects.

  14. The relationship between the parameters (Heart rate, Ejection fraction and BMI) and the maximum enhancement time of ascending aorta

    International Nuclear Information System (INIS)

    Jang, Young Ill; June, Woon Kwan; Dong, Kyeong Rae

    2007-01-01

    In this study, Bolus Tracking method was used to investigate the parameters affecting the time when contrast media is reached at 100 HU (T 100 ) and studied the relationship between parameters and T 100 because the time which is reached at aorta through antecubital vein after injecting contrast media is different from person to person. Using 64 MDCT, Cadiac CT, the data were obtained from 100 patients (male: 50, female: 50, age distribution: 21⁓81, average age: 57.5) during July and September, 2007 by injecting the contrast media at 4 ml∙sec -1 through their antecubital vein except having difficulties in stopping their breath and having arrhythmia. Using Somatom Sensation Cardiac 64 Siemens, patients’ height and weight were measured to know their mean Heart rate and BMI. Ejection Fraction was measured using Argus Program at Wizard Workstation. Variances of each parameter were analyzed depending on T 100 ’s variation with multiple comparison and the correlation of Heart rate, Ejection Fraction and BMI were analyzed, as well. According to T 100 ’s variation caused by Heart rate, Ejection Fraction and BMI variations, the higher patients’ Heart Rate and Ejection Fraction were, the faster T 100 ’s variations caused by Heart Rate and Ejection Fraction were. The lower their Heart Rate and Ejection Fraction were, the slower T 100 ’s variations were, but T 100 ’s variations caused by BMI were not affected. In the correlation between T 100 and parameters, Heart Rate (p⁄0.01) and Ejection Fraction (p⁄0.05) were significant, but BMI was not significant (p¤0.05). In the Heart Rate, Ejection Fraction and BMI depending on Fast (17 sec and less), Medium (18⁓21 sec), Slow (22 sec and over) Heart Rate was significant at Fast and Slow and Ejection Fraction was significant Fast and Slow as well as Medium and Slow (p⁄0.05), but BMI was not statistically significant. Of the parameters (Heart Rate, Ejection Fraction and BMI) which would affect T 100 , Heart

  15. Effects of omega-3 fatty acids on resting heart rate, heart rate recovery after exercise, and heart rate variability in men with healed myocardial infarctions and depressed ejection fractions.

    Science.gov (United States)

    O'Keefe, James H; Abuissa, Hussam; Sastre, Antonio; Steinhaus, David M; Harris, William S

    2006-04-15

    We explored possible mechanisms by which recommended intakes of omega-3 fatty acids may decrease the risk for sudden cardiac death in patients with documented coronary heart disease. The cardioprotective effects of omega-3 fatty acids have been documented in epidemiologic and randomized controlled trials. These fatty acids are presumed to decrease susceptibility to fatal arrhythmias, but whether this is mediated by classic risk factors or direct cardiac mechanisms is not known. Eighteen white men with a history of myocardial infarction and ejection fractions <40% were randomized to placebo or omega-3 fatty acids (585 mg of docosahexaenoic acid and 225 mg of eicosapentaenoic acid) for two 4-month periods in a crossover design. At the end of each period, heart rate (HR), HR variability, and rate of HR recovery after exercise were determined, as were effects on arterial compliance, blood pressure, cardiac function, and fasting serum levels of lipids and inflammatory markers. Omega-3 fatty acids decreased HR at rest from 73 +/- 13 to 68 +/- 13 beats/min (p <0.0001) and improved 1-minute HR recovery after exercise (-27 +/- 10 to -32 +/- 12 beats/min, p <0.01). HR variability in the high-frequency band increased (p <0.02), but no change was noted in overall HR variability. There were no significant effects on blood pressure, arterial compliance, lipids, or inflammatory markers. These changes are consistent with an increase in vagal activity and may in part explain the observed decrease in risk for sudden cardiac death seen with omega-3 fatty acid supplementation.

  16. Changes in heart rate variability and QT variability during the first trimester of pregnancy.

    Science.gov (United States)

    Carpenter, R E; D'Silva, L A; Emery, S J; Uzun, O; Rassi, D; Lewis, M J

    2015-03-01

    The risk of new-onset arrhythmia during pregnancy is high, presumably relating to changes in both haemodynamic and cardiac autonomic function. The ability to non-invasively assess an individual's risk of developing arrhythmia during pregnancy would therefore be clinically significant. We aimed to quantify electrocardiographic temporal characteristics during the first trimester of pregnancy and to compare these with non-pregnant controls. Ninety-nine pregnant women and sixty-three non-pregnant women underwent non-invasive cardiovascular and haemodynamic assessment during a protocol consisting of various physiological states (postural manoeurvres, light exercise and metronomic breathing). Variables measured included stroke volume, cardiac output, heart rate, heart rate variability, QT and QT variability and QTVI (a measure of the variability of QT relative to that of RR). Heart rate (p pregnancy only during the supine position (p pregnancy in all physiological states (p pregnancy in all states (p pregnancy is associated with substantial changes in heart rate variability, reflecting a reduction in parasympathetic tone and an increase in sympathetic activity. QTVI shifted to a less favourable value, reflecting a greater than normal amount of QT variability. QTVI appears to be a useful method for quantifying changes in QT variability relative to RR (or heart rate) variability, being sensitive not only to physiological state but also to gestational age. We support the use of non-invasive markers of cardiac electrical variability to evaluate the risk of arrhythmic events in pregnancy, and we recommend the use of multiple physiological states during the assessment protocol.

  17. Non-contact Real-time heart rate measurements based on high speed circuit technology research

    Science.gov (United States)

    Wu, Jizhe; Liu, Xiaohua; Kong, Lingqin; Shi, Cong; Liu, Ming; Hui, Mei; Dong, Liquan; Zhao, Yuejin

    2015-08-01

    In recent years, morbidity and mortality of the cardiovascular or cerebrovascular disease, which threaten human health greatly, increased year by year. Heart rate is an important index of these diseases. To address this status, the paper puts forward a kind of simple structure, easy operation, suitable for large populations of daily monitoring non-contact heart rate measurement. In the method we use imaging equipment video sensitive areas. The changes of light intensity reflected through the image grayscale average. The light change is caused by changes in blood volume. We video the people face which include the sensitive areas (ROI), and use high-speed processing circuit to save the video as AVI format into memory. After processing the whole video of a period of time, we draw curve of each color channel with frame number as horizontal axis. Then get heart rate from the curve. We use independent component analysis (ICA) to restrain noise of sports interference, realized the accurate extraction of heart rate signal under the motion state. We design an algorithm, based on high-speed processing circuit, for face recognition and tracking to automatically get face region. We do grayscale average processing to the recognized image, get RGB three grayscale curves, and extract a clearer pulse wave curves through independent component analysis, and then we get the heart rate under the motion state. At last, by means of compare our system with Fingertip Pulse Oximeter, result show the system can realize a more accurate measurement, the error is less than 3 pats per minute.

  18. Effects of Interval Training Programme on Resting Heart Rate in ...

    African Journals Online (AJOL)

    DATONYE ALASIA

    Subjects with Hypertension: A Randomized Controlled Trial. Type of Article: Original ... Resting Heart Rate in Subjects with Hypertension — Lamina S. et al investigate the effect of interval .... changes in VO max) of interest. In the t-test. 2.

  19. Imaging QRS complex and ST segment in myocardial infarction

    DEFF Research Database (Denmark)

    Bacharova, Ljuba; Bang, Lia E; Szathmary, Vavrinec

    2014-01-01

    BACKGROUND: Acute myocardial infarction creates regions of altered electrical properties of myocardium resulting in typical QRS patterns (pathological Q waves) and ST segment deviations observed in leads related to the MI location. The aim of this study was to present a graphical method for imaging...... the changes in the sequence of depolarization and the ST segment deviations in myocardial infarction using the Dipolar ElectroCARdioTOpography (DECARTO) method. MATERIAL AND METHODS: Simulated ECG data corresponding to intramural, electrically inactive areas encircled by transmural areas with slowed impulse...... propagation velocity in anteroseptal and inferior locations were used for imaging the altered sequence of depolarization and the ST vector. The ECGs were transformed to areas projected on the image surface so as to image the process of ventricular depolarization based on the orientation and magnitude...

  20. Modest weight loss in moderately overweight postmenopausal women improves heart rate variability

    DEFF Research Database (Denmark)

    Mouridsen, Mette Rauhe; Bendsen, Nathalie Tommerup; Astrup, Arne

    2013-01-01

    Purpose: To evaluate the effects of weight loss on heart rate (HR) and heart rate variability (HRV) parameters in overweight postmenopausal women. Design and Methods: Forty-nine overweight postmenopausal women with an average body mass index of 28.8 1.9 kg/m2 underwent a 12-week dietary weight......-to-normal intervals for each 5-min period (SDNNindex). Baseline body fat mass (FM%) and changes in body composition was determined by dual X-ray absorptiometry. Before and after the weight-loss period, total abdominal fat, intra-abdominal fat (IAAT), and subcutaneous abdominal fat (SCAT) were measured by single...

  1. Decreased heart rate variability in surgeons during night shifts

    DEFF Research Database (Denmark)

    Amirian, Ilda; Toftegård Andersen, Lærke; Rosenberg, Jacob

    2014-01-01

    BACKGROUND: Heart rate variability (HRV) has been used as a measure of stress and mental strain in surgeons. Low HRV has been associated with death and increased risk of cardiac events in the general population. The aim of this study was to clarify the effect of a 17-hour night shift on surgeons'...

  2. Anti-Hyperlipidaemic and Heart Rate Lowering Effects of Aqueous ...

    African Journals Online (AJOL)

    The anti-hyperlipidaemic and heart rate lowering potential of aqueous leaf extract of Viscum album (mistletoe) in hypercholesterolaemic rats was investigated in this study. The lethality studies showed that the aqueous extract of the plant had an LD50 value of 452.20mg/kg by intraperitoneal route. There were significant ...

  3. Importance of heart rate during exercise for response to cardiac resynchronization therapy.

    Science.gov (United States)

    Maass, Alexander H; Buck, Sandra; Nieuwland, Wybe; Brügemann, Johan; van Veldhuisen, Dirk J; Van Gelder, Isabelle C

    2009-07-01

    Cardiac resynchronization therapy (CRT) is an established therapy for patients with severe heart failure and mechanical dyssynchrony. Response is only achieved in 60-70% of patients. To study exercise-related factors predicting response to CRT. We retrospectively examined consecutive patients in whom a CRT device was implanted. All underwent cardiopulmonary exercise testing prior to implantation and after 6 months. The occurrence of chronotropic incompetence and heart rates exceeding the upper rate of the device, thereby compromising biventricular stimulation, was studied. Response was defined as a decrease in LVESV of 10% or more after 6 months. We included 144 patients. After 6 months 86 (60%) patients were responders. Peak VO2 significantly increased in responders. Chronotropic incompetence was more frequently seen in nonresponders (21 [36%] vs 9 [10%], P = 0.03), mostly in patients in SR. At moderate exercise, defined as 25% of the maximal exercise tolerance, that is, comparable to daily life exercise, nonresponders more frequently went above the upper rate of the device (13 [22%] vs 2 [3%], P exercise (OR 15.8 [3.3-76.5], P = 0.001) and nonischemic cardiomyopathy (OR 2.4 [1.0-5.7], P = 0.04) as predictive for response. Heart rate exceeding the upper rate during moderate exercise is an independent predictor for nonresponse to CRT in patients with AF, whereas chronotropic incompetence is a predictor for patients in SR.

  4. Cardiovascular health screening among South African students | du ...

    African Journals Online (AJOL)

    Subjects underwent a non-invasive ViportTM test which measures the cardio stress index (CSI), heart rate (HR), and QRS duration. Additional variables measured included: age, gender, perceived stress level, systolic and diastolic blood pressure and body mass index. Results obtained from the study indicate that students ...

  5. Safety and efficacy of a drug regimen to control heart rate during 64-slice ECG-gated coronary CTA in children

    International Nuclear Information System (INIS)

    Rigsby, Cynthia K.; Nicholas, Angela C.; deFreitas, R.A.; Leidecker, Christianne; Johanek, Andrew J.; Anley, Peter; Wang, Deli; Uejima, Tetsu

    2010-01-01

    The adult practice for ECG-gated single-source 64-slice coronary CTA (CCTA) includes administering beta-blockers to reduce heart rate. There are limited data on this process in children. To evaluate the safety and efficacy of a drug regimen to decrease heart rate before performing CCTA in children. IV remifentanil and esmolol infusion were chosen to decrease heart rate in 41 children (mean age 6.5 years) while they were under general anesthesia (GA) for CCTA. Drug doses, changes in heart rate and procedural complications were recorded. CCTA image quality was graded on a scale of 1 to 5. The relationships between image quality and heart rate and image quality and age were evaluated. Patient effective radiation doses were calculated. Heart rates were lowered utilizing esmolol (4 children), remifentanil (2 children) or both (35 children); 26 children received nitroglycerin for coronary vasodilation. The mean decrease in heart rate was 26%. There were no major complications. The average image-quality score was 4.4. Higher heart rates were associated with worse image quality (r = 0.67, P < 0.0001). Older age was associated with better image quality (r = 0.66, P < 0.0001). Effective radiation doses were 0.7 to 7.0 mSv. Heart rate reduction for pediatric CCTA can be safely and effectively achieved while yielding high-quality images. (orig.)

  6. Attachment Status Affects Heart Rate Responses to Experimental Ostracism in Inpatients with Depression.

    Directory of Open Access Journals (Sweden)

    Jannika De Rubeis

    Full Text Available Depression is assumed to be both a risk factor for rejection and a result of it, and as such constitutes an important factor in rejection research. Attachment theory has been applied to understand psychological disorders, such as depression, and can explain individual differences in responses to rejection. Research on autonomic nervous system activity to rejection experiences has been contradictory, with opposing strings of argumentation (activating vs. numbing. We investigated autonomic nervous system-mediated peripheral physiological responses (heart rate to experimentally manipulated ostracism (Cyberball in 97 depressed patients with organized (n = 52 and disorganized attachment status (n = 45. Controlling for baseline mean heart rate levels, depressed patients with disorganized attachment status responded to ostracism with significantly higher increases in heart rate than depressed patients with organized attachment status (p = .029; ηp2 = .051. These results suggest that attachment status may be a useful indicator of autonomic responses to perceived social threat, which in turn may affect the therapeutic process and the patient-therapist relationship.

  7. Heart rate variability changes in physicians working on night call.

    Science.gov (United States)

    Malmberg, Birgitta; Persson, Roger; Flisberg, Per; Ørbaek, Palle

    2011-03-01

    Adverse effects by night-call duty have become an important occupational health issue. The aim of this study was to investigate whether the heart rate variability (HRV) differed during recovery from day work and night-call duty between distinct physician specialities. We studied the impact of a 16-h night-call duty on autonomic balance, measured by HRV, among two physician groups differing with respect to having to deal with life-threatening conditions while on call. Nineteen anaesthesiologists (ANEST) and 16 paediatricians and ear, nose and throat surgeons (PENT) were monitored by ambulatory digital Holter electrocardiogram (ECG). Heart rate variability was analysed between 21:00 and 22:00 after an ordinary workday, on night call and in the evening post-call. Absolute and normalized high-frequency power (HF, HFnu) were the main outcome variables, expressing parasympathetic influence on the heart. ANEST had lower HF power than PENT while on night call and post-daytime work (p work compared with post-night-call duty (p balance and did not differ between specialities. However, the less dynamic HRV after daytime work and during night-call duty in the ANEST group may indicate a higher physiological stress level. These results may contribute to the improvement of night-call schedules within the health care sector.

  8. The Effect of 8 Weeks Yoga Training on Respiratory Function and Heart Rate of Non-Athlete Females

    Directory of Open Access Journals (Sweden)

    KH

    2015-07-01

    Conclusions: Results of this study showed that 8 weeks of practicing yoga and pranayama to increase vital capacity and forced expiratory volume in the first second and decreased heart rate and respiratory rate at rest is. Keywords: Yoga, Pranayama, spirometric indices, heart rate

  9. Playing a violent television game affects heart rate variability.

    Science.gov (United States)

    Ivarsson, Malena; Anderson, Martin; Akerstedt, Torbjörn; Lindblad, Frank

    2009-01-01

    To investigate how playing a violent/nonviolent television game during the evening affects sympathetic and parasympathetic reactions during and after playing as well as sleep quality during the night after playing. In total, 19 boys, 12-15 years of age, played television games on two occasions in their homes and participated once without gaming. Heart rate, heart rate variability (HRV) and physical activity were measured during gaming/participating and the night to follow using a portable combined heart rate and movement sensor. A sleep diary and questionnaires about gaming experiences and session-specific experiences were filled in. Criteria for Selection of Games: Violent game involves/rewards direct physical violence (no handguns) against another person, and nonviolent game involves/rewards no violence; same game design ('third-person game'); conducted in the same manner; no differences concerning motor activity; similar sound and light effects; no sexual content, violence against women or racial overtones. During violent (vs. nonviolent) gaming, there was significantly higher activity of the very low frequency component of the HRV and total power. During the night after playing, very low frequency, low frequency and high frequency components were significantly higher during the violent (vs. nonviolent) condition, just as total power. There were no significant differences between the three conditions (violent/nonviolent/no gaming) with respect to an index reflecting subjectively perceived sleep difficulties. Nor was there any difference between violent and nonviolent condition for any single sleep item. Violent gaming induces different autonomic responses in boys compared to nonviolent gaming--during playing and during the following night--suggesting different emotional responses. Subjectively perceived sleep quality is not influenced after a single gaming experience. Future studies should address the development of the autonomic balance after gaming over longer

  10. Self-rating level of perceived exertion for guiding exercise intensity during a 12-week cardiac rehabilitation programme and the influence of heart rate reducing medication

    DEFF Research Database (Denmark)

    Tang, Lars H.; Zwisler, Ann-Dorthe; Taylor, Rod S

    2016-01-01

    OBJECTIVES: To investigate whether self-rating level of perceived exertion can adequately guide exercise intensity during a 12-week cardiac rehabilitation programme. DESIGN: Linear regression analysis using rehabilitation data from two randomised controlled trials. METHODS: Patients undergoing ra......-led and self-regulated model using rating of perceived exertion can help guide exercise intensity in everyday clinical practice among patients with heart disease, irrespective if they are taking heart rate-reducing medication....... radiofrequency ablation for atrial fibrillation or following heart valve surgery and participating in exercise-based rehabilitation were included. The 12-week rehabilitation outpatient programme comprised three weekly training sessions, each consisting of 20min aerobic exercise divided into three steps. Patients...... were asked to base their exercise intensity for each step on a predefined rating of perceived exertion specified in a training diary. Exercise intensity was objectively measured by heart rate during the last 2min for each exercise step. Comparative analysis and linear regression of the rating...

  11. Electrocardiography of Grevy's zebras (Equus grevyi).

    Science.gov (United States)

    Myers, Debbie A; Citino, Scott; Mitchell, Mark A

    2008-09-01

    Electrocardiograms (ECGs) are a good baseline test for assessing cardiac rhythm. ECGs have not been reported in any zebra species and in very few Perissodactyla species. Standard limb, six-lead ECGs were recorded in 23 anesthetized Grevy's zebras (Equus grevyi). Heart rate, RR interval, P-wave duration, RR maximum/minimum, PR interval, QRS duration, QT interval, ST segment deviation, P-wave amplitude, QRS amplitude, and T-wave amplitude were measured and calculated from lead II ECGs from these Grevy's zebras. Several variables were tested, including gender, age (0-24, 24-48, 48-180, and >180 mo), weight (350 kg), pregnancy status, and anesthetic differences (standard dose or supplemented dose), to see if they affected ECG values in these animals. There were no significant differences in any of the ECG parameters between genders. RR and QT intervals were longer in older zebras; heart rates were faster in younger zebras. The RR and PR intervals, as well as the QRS duration, were greater in heavier zebras; heart rates were faster in lighter zebras. The RR interval was significantly longer in pregnant zebras. There were no significant differences in any of the ECG parameters for zebras anesthetized with a standardized dose of the drug combination etorphine-detomidine-acepromazine compared to those receiving additional supplements of these drugs and/or ketamine. All other parameters were not significantly different among groups, except where noted previously. The results of this research indicate that differences in ECG parameters in zebras may occur between animals of different ages, weights, and pregnancy status and that these factors should be considered when interpreting the respective ECGs of these zebras.

  12. The Influence of Motor Impairment on Autonomic Heart Rate Modulation among Children with Cerebral Palsy

    Science.gov (United States)

    Zamuner, Antonio Roberto; Cunha, Andrea Baraldi; da Silva, Ester; Negri, Ana Paola; Tudella, Eloisa; Moreno, Marlene Aparecida

    2011-01-01

    The study of heart rate variability is an important tool for a noninvasive evaluation of the neurocardiac integrity. The present study aims to evaluate the autonomic heart rate modulation in supine and standing positions in 12 children diagnosed with cerebral palsy and 16 children with typical motor development (control group), as well as to…

  13. Validity of (Ultra-)Short Recordings for Heart Rate Variability Measurements

    NARCIS (Netherlands)

    Muñoz Venegas, Loretto; van Roon, Arie; Riese, Harriette; Thio, Chris; Oostenbroek, Emma; Westrik, Iris; de Geus, Eco J. C.; Gansevoort, Ron; Lefrandt, Joop; Nolte, Ilja M.; Snieder, Harold

    2015-01-01

    Objectives In order to investigate the applicability of routine 10s electrocardiogram (ECG) recordings for time-domain heart rate variability (HRV) calculation we explored to what extent these (ultra-)short recordings capture the "actual" HRV. Methods The standard deviation of normal-to-normal

  14. Individual variability in heart rate recovery after standardized submaximal exercise

    NARCIS (Netherlands)

    van der Does, Hendrike; Brink, Michel; Visscher, Chris; Lemmink, Koen

    2012-01-01

    To optimize performance, coaches and athletes are always looking for the right balance between training load and recovery. Therefore, closely monitoring of athletes is important. Heart rate recovery (HRR) after standardized sub maximal exercise has been proposed as a useful variable to monitor

  15. The intubating laryngeal mask produces less heart rate response to ...

    African Journals Online (AJOL)

    Pc

    We compared heart rate and blood pressure changes to intubation produced by conventional laryngoscopic-guided intubation to those produced by blind intubation through the intubating laryngeal mask (ILM) in normotensive adults with normal airways. Forty paralysed, anaesthetised adults undergoing elective surgery ...

  16. Relationship between exercise heart rate and music tempo preference

    OpenAIRE

    Karageorghis, CI; Jones, L; Low, DC

    2006-01-01

    The present study examined the predicted positive and linear relationship (Iwanaga, 1995a,1995b) between exercise heart rate and music tempo preference. Initially, 128 undergraduates (M 3 age = 20.0 years, SD = 0.9 years) were surveyed to establish their three favorite music artists of all time. A separate experimental group of 29 undergraduates (M age = 20.3 years, SD = 1.2 years) selected the music of a single artist from a choice of the three highest-rated artists from the earlier survey. ...

  17. Intermittent Auscultation for Intrapartum Fetal Heart Rate Surveillance: American College of Nurse-Midwives.

    Science.gov (United States)

    2015-01-01

    Fetal heart rate surveillance is a standard component of intrapartum care. The fetal heart rate can be evaluated using intermittent auscultation or electronic fetal monitoring. Research that has compared these 2 strategies found them to be equivalent with respect to long-term neonatal outcomes. The purpose of this clinical bulletin by the American College of Nurse-Midwives is to review the evidence for use of intermittent auscultation and provide recommendations for intermittent auscultation technique, interpretation, and documentation. © 2015 by the American College of Nurse-Midwives.

  18. Deficient maternal zinc intake-but not folate-is associated with lower fetal heart rate variability.

    Science.gov (United States)

    Spann, Marisa N; Smerling, Jennifer; Gustafsson, Hanna; Foss, Sophie; Altemus, Margaret; Monk, Catherine

    2015-03-01

    Few studies of maternal prenatal diet and child development examine micronutrient status in relation to fetal assessment. Twenty-four-hour dietary recall of zinc and folate and 20min of fetal heart rate were collected from 3rd trimester pregnant adolescents. Deficient zinc was associated with less fetal heart rate variability. Deficient folate had no associations with HRV. Neither deficient zinc nor deficient folate was related to fetal heart rate. These findings, from naturalistic observation, are consistent with emerging data on prenatal zinc supplementation using a randomized control design. Taken together, the findings suggest that maternal prenatal zinc intake is an im