WorldWideScience

Sample records for heart rate fc

  1. 75 FR 52528 - FC Landfill Energy, LLC; Supplemental Notice That Initial Market-Based Rate Filing Includes...

    Science.gov (United States)

    2010-08-26

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. ER10-2268-000] FC Landfill Energy, LLC; Supplemental Notice That Initial Market- Based Rate Filing Includes Request for Blanket... proceeding, of FC Landfill Energy, LLC's application for market-based rate authority, with an accompanying...

  2. Heart rate index

    DEFF Research Database (Denmark)

    Haedersdal, C; Pedersen, F H; Svendsen, J H

    1992-01-01

    after the myocardial infarction. A significant correlation (Spearman's correlation coefficient rs, p less than 0.05) was found between LVEF at rest and the following variables assessed at exercise test: 1) the heart rate at rest, 2) rise in heart rate, 3) ratio between maximal heart rate and heart rate...... at rest, 4) rise in systolic blood pressure, 5) rate pressure product at rest, 6) rise in rate pressure product, 7) ratio (rHR) between maximal rate pressure product and rate pressure product at rest, 8) total exercise time. The heart rate was corrected for effects caused by age (heart index (HR...

  3. Relationship between Cardiometabolic Parameters and Elevated Resting and Effort Heart Rate in Schoolchildren.

    Science.gov (United States)

    Silva, Cristiane Fernanda da; Burgos, Miria Suzana; Silva, Priscila Tatiana da; Burgos, Leandro Tibiriçá; Welser, Letícia; Sehn, Ana Paula; Horta, Jorge André; Mello, Elza Daniel de; Reuter, Cézane Priscila

    2017-09-01

    Little has been studied on heart rate and its relationship with metabolic disorders. To identify possible association between heart rate (HR) and metabolic disorders in children and adolescents. This cross-sectional study evaluated 2.098 subjects, aged between 7 and 17 years. The variables evaluated were: HR, systolic (SBP) and diastolic blood pressure (DBP), pulse pressure (PP), double-product (DP), myocardial oxygen consumption (mVO2), lipids, glucose and uric acid levels, body mass index (BMI) and waist circumference (WC). The values of HR at rest and effort were divided into quartiles. The association between continuous values of HR and cardiometabolic indicators was tested by linear regression. LDL cholesterol presented a significantly higher mean (p = 0.003) in schoolchildren with resting HR greater or equal to 91 bpm, compared to students with less than 75 bpm. Compared with the quartiles of effort HR, SBP, DBP, glucose and uric acid presented high values when HR was greater or equal than 185 bpm. SBP, glucose and HDL cholesterol demonstrated a significant association with resting HR. Uric acid was observed as a predictor of increased effort HR. Schoolchildren with a higher resting HR have higher mean of LDL cholesterol. For effort HR, there was an increase in blood pressure, glucose and uric acid levels. Uric acid has been shown to be a predictor of elevated effort HR. Pouco se tem estudado sobre frequência cardíaca e suas relações com alterações metabólicas. Verificar se existe associação entre frequência cardíaca e disfunções metabólicas em crianças e adolescentes. Estudo transversal com 2.098 escolares, com idade entre 7 e 17 anos. As variáveis avaliadas foram: frequência cardíaca (FC), pressão arterial sistólica (PAS), diastólica (PAD) e de pulso (PP), duplo-produto (DP), consumo de oxigênio pelo miocárdio (mVO2), perfil lipídico e glicêmico, níveis de ácido úrico, índice de massa corporal (IMC) e circunferência da cintura

  4. Efectos del entrenamiento continuo e interválico de carga externa similar sobre la frecuencia cardiaca Effects of continuous and interval training similar external load on heart rate

    Directory of Open Access Journals (Sweden)

    J. L. Tuimil

    2010-09-01

    Full Text Available

     

    Los objetivos de este estudio fueron comparar la frecuencia cardíaca (FC media entre dos tipos de entrenamiento de carga externa equiparada basados en la carrera, la relación de la velocidad aeróbica máxima (VAM con la F.C. de reserva (FCR y los efectos de estos dos tipos de entrenamiento sobre la F.C. basal (FCB. El estudio se llevó a cabo con ocho estudiantes de educación física (23,25 años; VAM: 17,93 Km.h-1 que realizaron dos tipos de entrenamiento: CC =8 km al 70%VAM y CI= 4x(1000m al 90%VAM+1000m al 50% VAM. Se registró la FC durante el entrenamiento y la FCB antes y después del mismo. La diferencia de la FC media entre ambos métodos no fue estadísticamente significativa, sin embargo las medias del CC (FCCC (Z=2,240; p<0,05 y CI (FCCI (Z=2,380; p<0,05 fueron significativamente más elevadas que la calculada al 70% de FCR. La FCB se elevó de forma significativa (Z=2,319; p=0.020 solamente después del entrenamiento CI. En conclusión, dos métodos de entrenamiento distintos, pero de intensidad media similar, pueden dar lugar a una FC media también similar. La intensidad de carrera programada en función de la VAM es significativamente superior a la programada en función de la FCR. El entrenamiento interválico puede tener un mayor efecto sobre el incremento de la FCB.
    PALABRAS CLAVE: Frecuencia cardíaca media, frecuencia cardíaca de reserva, frecuencia cardíaca basal, VAM, carrera continua, carrera interválica.

    The aims of this study were to compare the mean heart rate response in two training methods of equal average intensity based on running, the relationship of the maximal aerobic speed (VAM with the reserve heart rate (FCR and the effects of these modes of training on the basal heart rate (FCB. The study was carried out with eight physical activity students (23,25 years old; VAM: 17,93 Km.h-1

  5. Effects of Liraglutide on Heart Rate and Heart Rate Variability

    DEFF Research Database (Denmark)

    Kumarathurai, Preman; Anholm, Christian; Larsen, Bjørn Strøier

    2017-01-01

    OBJECTIVE: Reduced heart rate variability (HRV) and increased heart rate (HR) have been associated with cardiovascular mortality. Glucagon-like peptide 1 receptor agonists (GLP-1 RAs) increase HR, and studies have suggested that they may reduce HRV. We examined the effect of the GLP-1 RA...

  6. Heart rate monitoring mobile applications

    OpenAIRE

    Chaudhry, Beenish M.

    2016-01-01

    Total number of times a heart beats in a minute is known as the heart rate. Traditionally, heart rate was measured using clunky gadgets but these days it can be measured with a smartphone?s camera. This can help you measure your heart rate anywhere and at anytime, especially during workouts so you can adjust your workout intensity to achieve maximum health benefits. With simple and easy to use mobile app, ?Unique Heart Rate Monitor?, you can also maintain your heart rate history for personal ...

  7. Heart rate monitoring mobile applications.

    Science.gov (United States)

    Chaudhry, Beenish M

    2016-01-01

    Total number of times a heart beats in a minute is known as the heart rate. Traditionally, heart rate was measured using clunky gadgets but these days it can be measured with a smartphone's camera. This can help you measure your heart rate anywhere and at anytime, especially during workouts so you can adjust your workout intensity to achieve maximum health benefits. With simple and easy to use mobile app, 'Unique Heart Rate Monitor', you can also maintain your heart rate history for personal reflection and sharing with a provider.

  8. Multivalent Fcγ-receptor engagement by a hexameric Fc-fusion protein triggers Fcγ-receptor internalisation and modulation of Fcγ-receptor functions.

    Science.gov (United States)

    Qureshi, O S; Rowley, T F; Junker, F; Peters, S J; Crilly, S; Compson, J; Eddleston, A; Björkelund, H; Greenslade, K; Parkinson, M; Davies, N L; Griffin, R; Pither, T L; Cain, K; Christodoulou, L; Staelens, L; Ward, E; Tibbitts, J; Kiessling, A; Smith, B; Brennan, F R; Malmqvist, M; Fallah-Arani, F; Humphreys, D P

    2017-12-06

    Engagement of Fcγ-receptors triggers a range of downstream signalling events resulting in a diverse array of immune functions. As a result, blockade of Fc-mediated function is an important strategy for the control of several autoimmune and inflammatory conditions. We have generated a hexameric-Fc fusion protein (hexameric-Fc) and tested the consequences of multi-valent Fcγ-receptor engagement in in vitro and in vivo systems. In vitro engagement of hexameric-Fc with FcγRs showed complex binding interactions that altered with receptor density and triggered the internalisation and degradation of Fcγ-receptors. This caused a disruption of Fc-binding and phagocytosis. In vivo, in a mouse ITP model we observed a short half-life of hexameric-Fc but were nevertheless able to observe inhibition of platelet phagocytosis several days after hexameric-Fc dosing. In cynomolgus monkeys, we again observed a short half-life, but were able to demonstrate effective FcγR blockade. These findings demonstrate the ability of multi-valent Fc-based therapeutics to interfere with FcγR function and a potential mechanism through which they could have a sustained effect; the internalisation and degradation of FcγRs.

  9. Heart rate response to breathing

    DEFF Research Database (Denmark)

    Mehlsen, J; Pagh, K; Nielsen, J S

    1987-01-01

    Heart rate responses to stepwise and periodic changes in lung volume were studied in seven young healthy males. Stepwise inspiration and expiration both resulted in an increase in heart rate followed by a rapid decrease in heart rate. The fastest heart rate was reached in 1.6 +/- 0.5 s and in 3.......6 +/- 1.4 s in response to inspiration and expiration, respectively (P less than 0.01). The slowest heart rate was reached in 4.8 +/- 1.0 s and in 7.6 +/- 1.9 s in response to inspiration and expiration, respectively (P less than 0.01). Following this biphasic change the heart rate returned to a steady...... level. The difference between the fastest and the slowest heart rates was significantly larger in response to inspiration (21.7 +/- 7.3 beats per minute) than in response to expiration (12.0 +/- 7.3 beats per minute; P less than 0.01). Periodic changes in lung volume were performed with frequencies from...

  10. Heart rate variability in healthy population

    International Nuclear Information System (INIS)

    Alamgir, M.; Hussain, M.M.

    2010-01-01

    Background: Heart rate variability has been considered as an indicator of autonomic status. Little work has been done on heart rate variability in normal healthy volunteers. We aimed at evolving the reference values of heart rate variability in our healthy population. Methods: Twenty-four hour holter monitoring of 37 healthy individuals was done using Holter ECG recorder 'Life card CF' from 'Reynolds Medical'. Heart rate variability in both time and frequency domains was analysed with 'Reynolds Medical Pathfinder Digital/700'. Results: The heart rate variability in normal healthy volunteers of our population was found in time domain using standard deviation of R-R intervals (SDNN), standard deviation of average NN intervals (SDANN), and Square root of the mean squared differences of successive NN intervals (RMSSD). Variation in heart rate variability indices was observed between local and foreign volunteers and RMSSD was found significantly increased (p<0.05) in local population. Conclusions: The values of heart rate variability (RMSSD) in healthy Pakistani volunteers were found increased compared to the foreign data reflecting parasympathetic dominance in our population. (author)

  11. Monitoring apparatus for monitoring a user's heart rate and/or heart rate variation

    NARCIS (Netherlands)

    2012-01-01

    A monitoring apparatus (4) monitors a user's heart rate and/or heart rate variation. The apparatus includes a capacitor (22) which is positionable on or near a body part of a person, for example a person's limb, for example an arm (3), such that an electrical capacitance of the capacitor (22) is

  12. Reduced Dietary Sodium Intake Increases Heart Rate

    DEFF Research Database (Denmark)

    Graudal, Niels A; Hubeck-Graudal, Thorbjørn; Jürgens, Gesche

    2016-01-01

    Reduced dietary sodium intake (sodium reduction) increases heart rate in some studies of animals and humans. As heart rate is independently associated with the development of heart failure and increased risk of premature death a potential increase in heart rate could be a harmful side......-effect of sodium reduction. The purpose of the present meta-analysis was to investigate the effect of sodium reduction on heart rate. Relevant studies were retrieved from an updated pool of 176 randomized controlled trials (RCTs) published in the period 1973-2014. Sixty-three of the RCTs including 72 study...... populations reported data on heart rate. In a meta-analysis of these data sodium reduction increased heart rate with 1.65 beats per minute [95% CI: 1.19, 2.11], p heart rate. This effect was independent of baseline blood pressure. In conclusion sodium reduction...

  13. Effects of social stress on heart rate and heart rate variability in growing pigs

    NARCIS (Netherlands)

    Jong, de I.C.; Sgoifo, A.; Lambooij, E.; Korte, S.M.; Blokhuis, H.J.; Koolhaas, J.M.

    2000-01-01

    The effects of social stress on heart rate, heart rate variability and the occurrence of cardiac arrhythmias were studied in 12 growing pigs. Social stress was induced during a good competition test with a pen mate, and subsequently during a resident-intruder test with an unacquainted pig in which

  14. Effects of social stress on heart rate and heart rate variability in growing pigs

    NARCIS (Netherlands)

    de Jong, IC; Sgoifo, A; Lambooij, E; Korte, SM; Blokhuis, HJ; Koolhaas, JM

    The effects of social stress on heart rate, heart rate variability and the occurrence of cardiac arrhythmias were studied in 12 growing pigs. Social stress was induced during a good competition test with a pen mate, and subsequently during a resident-intruder test with an unacquainted pig in which

  15. Thermal decomposition of FC(O)OCH3 and FC(O)OCH2CH3.

    Science.gov (United States)

    Berasategui, M; Argüello, G A; Burgos Paci, M A

    2018-05-09

    The thermal decomposition of methyl and ethyl formates has been extensively studied due to their importance in the oxidation of several fuels, pesticidal properties and their presence in interstellar space. We hitherto present the study of the thermal decomposition of methyl and ethyl fluoroformates, which could help in the elucidation of the reaction mechanisms. The reaction mechanisms were studied using FTIR spectroscopy in the temperature range of 453-733 K in the presence of different pressures of N2 as bath gas. For FC(O)OCH3 two different channels were observed; the unimolecular decomposition which is favored at higher temperatures and has a rate constant kFC(O)OCH3 = (5.3 ± 0.5) × 1015 exp[-(246 ± 10 kJ mol-1/RT)] (in units of s-1) and a bimolecular channel with a rate constant kFC(O)OCH3 = (1.6 ± 0.5) × 1011 exp[-(148 ± 10 kJ mol-1/RT)] (in units of s-1 (mol L)-1). However for ethyl formate, only direct elimination of CO2, HF and ethylene operates. The rate constants of the homogeneous first-order process fit the Arrhenius equation kFC(O)OCH2CH3 = (2.06 ± 0.09) × 1013 exp[-(169 ± 6 kJ mol-1/RT)] (in units of s-1). The difference between the mechanisms of the two fluoroformates relies on the stabilization of a six-centered transition state that only exists for ethyl formate. First principles calculations for the different channels were carried out to understand the dynamics of the decomposition.

  16. Dimensional analysis of heart rate variability in heart transplant recipients

    Energy Technology Data Exchange (ETDEWEB)

    Zbilut, J.P.; Mayer-Kress, G.; Geist, K.

    1987-01-01

    We discuss periodicities in the heart rate in normal and transplanted hearts. We then consider the possibility of dimensional analysis of these periodicities in transplanted hearts and problems associated with the record.

  17. FPGA Implementation of Heart Rate Monitoring System.

    Science.gov (United States)

    Panigrahy, D; Rakshit, M; Sahu, P K

    2016-03-01

    This paper describes a field programmable gate array (FPGA) implementation of a system that calculates the heart rate from Electrocardiogram (ECG) signal. After heart rate calculation, tachycardia, bradycardia or normal heart rate can easily be detected. ECG is a diagnosis tool routinely used to access the electrical activities and muscular function of the heart. Heart rate is calculated by detecting the R peaks from the ECG signal. To provide a portable and the continuous heart rate monitoring system for patients using ECG, needs a dedicated hardware. FPGA provides easy testability, allows faster implementation and verification option for implementing a new design. We have proposed a five-stage based methodology by using basic VHDL blocks like addition, multiplication and data conversion (real to the fixed point and vice-versa). Our proposed heart rate calculation (R-peak detection) method has been validated, using 48 first channel ECG records of the MIT-BIH arrhythmia database. It shows an accuracy of 99.84%, the sensitivity of 99.94% and the positive predictive value of 99.89%. Our proposed method outperforms other well-known methods in case of pathological ECG signals and successfully implemented in FPGA.

  18. Reduced intrinsic heart rate is associated with reduced arrhythmic susceptibility in guinea-pig heart.

    Science.gov (United States)

    Osadchii, Oleg E

    2014-12-01

    In the clinical setting, patients with slower resting heart rate are less prone to cardiovascular death compared with those with elevated heart rate. However, electrophysiological adaptations associated with reduced cardiac rhythm have not been thoroughly explored. In this study, relationships between intrinsic heart rate and arrhythmic susceptibility were examined by assessments of action potential duration (APD) rate adaptation and inducibility of repolarization alternans in sinoatrial node (SAN)-driven and atrioventricular (AV)-blocked guinea-pig hearts perfused with Langendorff apparatus. Electrocardiograms, epicardial monophasic action potentials, and effective refractory periods (ERP) were assessed in normokalemic and hypokalemic conditions. Slower basal heart rate in AV-blocked hearts was associated with prolonged ventricular repolarization during spontaneous beating, and with attenuated APD shortening at increased cardiac activation rates during dynamic pacing, when compared with SAN-driven hearts. During hypokalemic perfusion, the inducibility of repolarization alternans and tachyarrhythmia by rapid pacing was found to be lower in AV-blocked hearts. This difference was ascribed to prolonged ERP in the setting of reduced basal heart rate, which prevented ventricular capture at critically short pacing intervals required to induce arrhythmia. Reduced basal heart rate is associated with electrophysiological changes that prevent electrical instability upon an abrupt cardiac acceleration.

  19. Engineering of Immunoglobulin Fc Heterodimers Using Yeast Surface-Displayed Combinatorial Fc Library Screening.

    Directory of Open Access Journals (Sweden)

    Hye-Ji Choi

    Full Text Available Immunoglobulin Fc heterodimers, which are useful scaffolds for the generation of bispecific antibodies, have been mostly generated through structure-based rational design methods that introduce asymmetric mutations into the CH3 homodimeric interface to favor heterodimeric Fc formation. Here, we report an approach to generate heterodimeric Fc variants through directed evolution combined with yeast surface display. We developed a combinatorial heterodimeric Fc library display system by mating two haploid yeast cell lines, one haploid cell line displayed an Fc chain library (displayed FcCH3A with mutations in one CH3 domain (CH3A on the yeast cell surface, and the other cell line secreted an Fc chain library (secreted FcCH3B with mutations in the other CH3 domain (CH3B. In the mated cells, secreted FcCH3B is displayed on the cell surface through heterodimerization with the displayed FcCH3A, the detection of which enabled us to screen the library for heterodimeric Fc variants. We constructed combinatorial heterodimeric Fc libraries with simultaneous mutations in the homodimer-favoring electrostatic interaction pairs K370-E357/S364 or D399-K392/K409 at the CH3 domain interface. High-throughput screening of the libraries using flow cytometry yielded heterodimeric Fc variants with heterodimer-favoring CH3 domain interface mutation pairs, some of them showed high heterodimerization yields (~80-90% with previously unidentified CH3 domain interface mutation pairs, such as hydrogen bonds and cation-π interactions. Our study provides a new approach for engineering Fc heterodimers that could be used to engineer other heterodimeric protein-protein interactions through directed evolution combined with yeast surface display.

  20. Heart-Rate Recovery After Warm-up in Swimming: A Useful Predictor of Training Heart-Rate Response?

    Science.gov (United States)

    Ganzevles, Sander P M; de Haan, Arnold; Beek, Peter J; Daanen, Hein A M; Truijens, Martin J

    2017-07-01

    For training to be optimal, daily training load has to be adapted to the momentary status of the individual athlete, which is often difficult to establish. Therefore, the current study investigated the predictive value of heart-rate recovery (HRR) during a standardized warm-up for training load. Training load was quantified by the variation in heart rate during standardized training in competitive swimmers. Eight female and 5 male Dutch national-level swimmers participated in the study. They all performed 3 sessions consisting of a 300-m warm-up test and a 10 × 100-m training protocol. Both protocols were swum in front crawl at individually standardized velocities derived from an incremental step test. Velocity was related to 75% and 85% heart-rate reserve (% HR res ) for the warm-up and training, respectively. Relative HRR during the first 60 s after the warm-up (HR Rw-up ) and differences between the actual and intended heart rate for the warm-up and the training (ΔHR w-up and ΔHR tr ) were determined. No significant relationship between HRR w-up and ΔHR tr was found (F 1,37 = 2.96, P = .09, R 2 = .07, SEE = 4.65). There was considerable daily variation in ΔHR tr at a given swimming velocity (73-93% HR res ). ΔHR w-up and ΔHR tr were clearly related (F 1,37 = 74.31, P warm-up does not predict heart rate during a directly subsequent and standardized training session. Instead, heart rate during the warm-up protocol seems a promising alternative for coaches to make daily individual-specific adjustments to training programs.

  1. Heart rate profile during exercise in patients with early repolarization.

    Science.gov (United States)

    Cay, Serkan; Cagirci, Goksel; Atak, Ramazan; Balbay, Yucel; Demir, Ahmet Duran; Aydogdu, Sinan

    2010-09-01

    Both early repolarization and altered heart rate profile are associated with sudden death. In this study, we aimed to demonstrate an association between early repolarization and heart rate profile during exercise. A total of 84 subjects were included in the study. Comparable 44 subjects with early repolarization and 40 subjects with normal electrocardiogram underwent exercise stress testing. Resting heart rate, maximum heart rate, heart rate increment and decrement were analyzed. Both groups were comparable for baseline characteristics including resting heart rate. Maximum heart rate, heart rate increment and heart rate decrement of the subjects in early repolarization group had significantly decreased maximum heart rate, heart rate increment and heart rate decrement compared to control group (all P decrement (multiple-adjusted OR of the risk of presence of early repolarization was 2.98 (95%CI 1.21-7.34) (P = 0.018) and 7.73 (95%CI 2.84-21.03) (P decrement compared to higher levels, respectively. Subjects with early repolarization have altered heart rate profile during exercise compared to control subjects. This can be related to sudden death.

  2. Genome-wide association studies and resting heart rate

    DEFF Research Database (Denmark)

    Oskari Kilpeläinen, Tuomas

    2016-01-01

    Genome-wide association studies (GWASs) have revolutionized the search for genetic variants regulating resting heart rate. In the last 10 years, GWASs have led to the identification of at least 21 novel heart rate loci. These discoveries have provided valuable insights into the mechanisms...... and pathways that regulate heart rate and link heart rate to cardiovascular morbidity and mortality. GWASs capture majority of genetic variation in a population sample by utilizing high-throughput genotyping chips measuring genotypes for up to several millions of SNPs across the genome in thousands...... of individuals. This allows the identification of the strongest heart rate associated signals at genome-wide level. While GWASs provide robust statistical evidence of the association of a given genetic locus with heart rate, they are only the starting point for detailed follow-up studies to locate the causal...

  3. Heart Rate Variability - A Historical Perspective

    Directory of Open Access Journals (Sweden)

    George E Billman

    2011-11-01

    Full Text Available Heart rate variability (HRV, the beat-to-beat variation in either heart rate or the duration of the R-R interval – the heart period, has become a popular clinical and investigational tool. The temporal fluctuations in heart rate exhibit a marked synchrony with respiration (increasing during inspiration and decreasing during expiration – the so called respiratory sinus arrhythmia, RSA and are widely believed to reflect changes in cardiac autonomic regulation. Although the exact contributions of the parasympathetic and the sympathetic divisions of the autonomic nervous system to this variability are controversial and remain the subject of active investigation and debate, a number of time and frequency domain techniques have been developed to provide insight into cardiac autonomic regulation in both health and disease. It is the purpose of this essay to provide an historical overview of the evolution in the concept of heart rate variability. Briefly, pulse rate was first measured by ancient Greek physicians and scientists. However, it was not until the invention of the Physician’s Pulse Watch (a watch with a second hand that could be stopped in 1707 that changes in pulse rate could be accurately assessed. The Rev. Stephen Hales (1733 was the first to note that pulse varied with respiration and in 1847 Carl Ludwig was the first to record RSA. With the measurement of the ECG (1895 and advent of digital signal processing techniques in the 1960’s, investigation of HRV and its relationship to health and disease has exploded. This essay will conclude with a brief description of time domain, frequency domain, and non-linear dynamic analysis techniques (and their limitations that are commonly used to measure heart rate variability.

  4. Peak heart rates at extreme altitudes

    DEFF Research Database (Denmark)

    Lundby, C; Van Hall, Gerrit

    2001-01-01

    We have measured maximal heart rate during a graded maximal bicycle exercise test to exhaustion in five healthy climbers before and during an expedition to Mt. Everest. Maximal heart rates at sea level were 186 (177-204) beats/min(-1) at sea level and 170 (169-182) beats/min(-1) with acute hypoxi...

  5. The effect of relaxing music on heart rate and heart rate variability during ECG GATED-myocardial perfusion scintigraphy.

    Science.gov (United States)

    Tan, Yusuf Ziya; Ozdemir, Semra; Temiz, Ahmet; Celik, Fatmanur

    2015-05-01

    The positive changes in human behavior caused by relaxing music demonstrate the psychological effect of music on human body. A meta-analytical study has shown that relaxing music affects blood pressure and heart rate in coronary heart patients and cancer patients. The aim of our study is to research whether there is a significant effect on heart rate and heart rate variability due to listening to relaxing music during ECG GATED MPS imaging under gamma camera. The music group (n = 50 patients) could choose from 15 different musical types including folk music (no lyric). The other 50 patients were placed in a "no music group" and did not get headphones or any music. There was a statistically significant reduction in the heart rate of patients in the music group compared to those in the control group. Relaxing music provides great benefits to both patient and clinician. There is close relationship between relaxing music and health procedure, can use every area of the health noninvasiv, safe, cheap and is a method don't have side effect. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Measuring heart rate with optical sensor

    NARCIS (Netherlands)

    Barachi, M. (Mitra)

    2014-01-01

    The problem addressed in this report is to verify the possibility of using an optical sensor in the SaxShirt in order to extract the heart rate. There are specifically three questions that we try to address. 1) How is it possible to extract heart rate (BPM) from the optical sensor? 2) Is it

  7. Validation of Heart Rate Monitor Polar RS800 for Heart Rate Variability Analysis During Exercise.

    Science.gov (United States)

    Hernando, David; Garatachea, Nuria; Almeida, Rute; Casajús, Jose A; Bailón, Raquel

    2018-03-01

    Hernando, D, Garatachea, N, Almeida, R, Casajús, JA, and Bailón, R. Validation of heart rate monitor Polar RS800 for heart rate variability analysis during exercise. J Strength Cond Res 32(3): 716-725, 2018-Heart rate variability (HRV) analysis during exercise is an interesting noninvasive tool to measure the cardiovascular response to the stress of exercise. Wearable heart rate monitors are a comfortable option to measure interbeat (RR) intervals while doing physical activities. It is necessary to evaluate the agreement between HRV parameters derived from the RR series recorded by wearable devices and those derived from an electrocardiogram (ECG) during dynamic exercise of low to high intensity. Twenty-three male volunteers performed an exercise stress test on a cycle ergometer. Subjects wore a Polar RS800 device, whereas ECG was also recorded simultaneously to extract the reference RR intervals. A time-frequency spectral analysis was performed to extract the instantaneous mean heart rate (HRM), and the power of low-frequency (PLF) and high-frequency (PHF) components, the latter centered on the respiratory frequency. Analysis was done in intervals of different exercise intensity based on oxygen consumption. Linear correlation, reliability, and agreement were computed in each interval. The agreement between the RR series obtained from the Polar device and from the ECG is high throughout the whole test although the shorter the RR is, the more differences there are. Both methods are interchangeable when analyzing HRV at rest. At high exercise intensity, HRM and PLF still presented a high correlation (ρ > 0.8) and excellent reliability and agreement indices (above 0.9). However, the PHF measurements from the Polar showed reliability and agreement coefficients around 0.5 or lower when the level of the exercise increases (for levels of O2 above 60%).

  8. Study Heart Rate by Tools from Complex Networks

    International Nuclear Information System (INIS)

    Makowiec, D.; Wdowczyk-Szulc, J.; Zarczynska-Buchowiecka, M.; Gruchala, M.; Rynkiewicz, A.

    2011-01-01

    Heart rate measured as beat-to-beat time intervals varies in time. It is believed that time intervals between subsequent normal heart contractions carry information about the regulatory system of the heart. How to quantify such signals is not clear and because of that heart rate variability is still apart from the clinic routine. In the following, we propose a method for representing a heart rate signal as a directed network. Then we study the signal properties by complex network tools. The signals to study were collected from patients recovering after the heart transplantation. The aim is to classify the progress of adapting of the new heart - graft. Moreover, it is expected that the method allows for visual classification. Our investigations are preliminary, however the obtained results are promising. (authors)

  9. Metaiodobenzylguanidine and heart rate variability in heart failure

    International Nuclear Information System (INIS)

    Kurata, Chinori; Shouda, Sakae; Mikami, Tadashi; Uehara, Akihiko; Ishikawa, Keiko; Tawarahara, Kei; Nakano, Tomoyasu; Matoh, Fumitaka; Takeuchi, Kazuhiko

    1998-01-01

    It is assumed that the low-frequency power (LF) of heart rate variability (HRV) increases with progress of congestive heart failure (CHF), therefore positively correlating with cardiac 123 I-metaiodobenzylguanidine (MIBG) washout. It is demonstrated here that HRV, including normalized LF, correlated inversely with MIBG washout and positively with the ratio of heart-to-mediastinum MIBG activity in controls and CHF patients, whereas these correlations were not observed within CHF patients. Thus MIBG washout may increase and HRV including normalized LF may decrease with CHF, although the HRV and MIBG measures may not similarly change in proportion to the severity of the cardiac autonomic dysfunction in CHF. (author)

  10. Metaiodobenzylguanidine and heart rate variability in heart failure

    Energy Technology Data Exchange (ETDEWEB)

    Kurata, Chinori; Shouda, Sakae; Mikami, Tadashi; Uehara, Akihiko; Ishikawa, Keiko [Hamamatsu Univ., Shizuoka (Japan). School of Medicine; Tawarahara, Kei; Nakano, Tomoyasu; Matoh, Fumitaka; Takeuchi, Kazuhiko

    1998-10-01

    It is assumed that the low-frequency power (LF) of heart rate variability (HRV) increases with progress of congestive heart failure (CHF), therefore positively correlating with cardiac {sup 123}I-metaiodobenzylguanidine (MIBG) washout. It is demonstrated here that HRV, including normalized LF, correlated inversely with MIBG washout and positively with the ratio of heart-to-mediastinum MIBG activity in controls and CHF patients, whereas these correlations were not observed within CHF patients. Thus MIBG washout may increase and HRV including normalized LF may decrease with CHF, although the HRV and MIBG measures may not similarly change in proportion to the severity of the cardiac autonomic dysfunction in CHF. (author)

  11. Predictive value of casual ECG-based resting heart rate compared with resting heart rate obtained from Holter recording

    DEFF Research Database (Denmark)

    Carlson, Nicholas; Dixen, Ulrik; Marott, Jacob L

    2014-01-01

    BACKGROUND: Elevated resting heart rate (RHR) is associated with cardiovascular mortality and morbidity. Assessment of heart rate (HR) from Holter recording may afford a more precise estimate of the effect of RHR on cardiovascular risk, as compared to casual RHR. Comparative analysis was carried ...

  12. The relationship between phase and heart rate

    International Nuclear Information System (INIS)

    Underwood, S.R.; Walton, S.; Brown, N.J.G.; Laming, P.J.; Ell, P.J.; Emanuel, R.W.; Swanton, R.H.

    1984-01-01

    The Fourier phase image is used in rest and stress radionuclide angiocardiography to assess the timing of ventricular wall motion in a regional fashion, and areas of high phase are taken to reprensent areas of delayed contraction. However, phase increases with heart rate and this can make interpretation difficult. This study investigates the relationship between phase and heart rate. A heterogenous group of 43 subjects was studied by ECG-gated equilibrium radionuclide angiocardiography, all of the subjects having normal extent of left ventricular wall motion as judged by normal ejection fraction and normal amplitude image. Mean left ventricular phase correlated well with mean time of end systole (r=0.92), but there was no correlation with time of end diastole.Thus phase reflects the time of end systole as a proportion of cycle length and should be linearly related to heart rate provided the duration of systole is unchanged. In 28 normal subjects mean left ventricular phase correlated linearly with resting rate (r=0.91), and when exercised the relationship was maintained up to 90 beats per minute. Above this rate the increases were less marked as the duration of systole shortened. The same was true in 4 subjects paced at different rates. Mean resting heart rate in the normal subjects was 70 beats per minute and correcting phase linearly to rate 70 did not change mean left ventricular phase but did decrease the standard deviation from 18 degree to 12 degree. It is concluded that correcting phase for heart rate below 90 beats per minute will increase the sensitivity of the phase image to abnormalities of the timing of ventricular contraction. This correction should be appropriate in resting, isometric exercise, and cold pressor studies but because of the higher heart rates involved will not be appropriate for bicycle exercise. (Author)

  13. Corrosion rate of steel embedded in blended Portland and fluid catalytic cracking catalyst residue (FC3R cement mortars

    Directory of Open Access Journals (Sweden)

    Payá, J.

    2008-12-01

    Full Text Available This paper reports on a study of the corrosion levels in steel bars embedded in mortars made with a blend of Portland cement and (0-20% spent fluid catalytic cracking catalyst residue (FC3R, with a variable (0.3-0.7 water/binder (w/b ratio. The specimens were stored in the following conditions: relative humidity of 40, 80 or 100% and CO2 concentrations of 5 and 100%. The steel corrosion rate was measured with polarization resistance techniques. In the absence of aggressive agents, the steel was found to remain duly passivated in mortars with an FC3R content of up to 15% under all the conditions of relative humidity tested. The reinforcement corrosion level in mortars with a w/b ratio of 0.3 and 15% FC3R subjected to accelerated carbonation was similar to the level observed in the unblended Portland cement control mortar.En este trabajo se ha estudiado el nivel de corrosión de barras de acero embebidas en morteros de cemento Portland con relación agua/material cementante (a/mc variable (0,3-0,7, en los que parte del cemento (0-20% se sustituyó por catalizador de craqueo usado (FC3R. Las condiciones de conservación de las probetas elaboradas fueron las siguientes: distintas humedades relativas (40, 80 y 100% y dos concentraciones de CO2 (5 y 100%. La velocidad de corrosión de los aceros se midió mediante la técnica de resistencia de polarización. Se ha podido determinar que, bajo las distintas condiciones de humedad relativa y ausencia de agresivo, los aceros se mantuvieron correctamente pasivados en los morteros con contenidos de FC3R de hasta el 15%. El nivel de corrosión que presenta el refuerzo embebidos en morteros con sustitución de un 15% de cemento por FC3R y relación a/mc 0,3, al ser sometidos a un proceso de carbonatación acelerada, era muy similar al mostrado por el mortero patrón, sin FC3R.

  14. FcγRll: Characterisation of novel Fc receptor interactions and a new receptor form.

    OpenAIRE

    JESSICA CLAIRE ANANIA

    2018-01-01

    Leukocyte Fc receptors (FcR) bind to immunogloulins (Ig) to link the innate and humoral immune system to help balance the immune system and clear infections. We have characterised a novel FcR for IgG (FcγR) form, designated FcγRIIa3, which contains a 19 amino acid insert. This insert interacts with cytoskeletal structures allowing the receptor to be retained for longer periods of time at the cells surface upon activation, higher cell signalling which causes greater cellular activation. Theref...

  15. The effect of metaprolol alone and metaprolol plus bromazepam on heart rate and heart rate variability during multislice computed tomography angiography

    International Nuclear Information System (INIS)

    Tuyyab, F.; Naeem, M.Y.; Maken, G.R.; Najfi, M.H.; Hassan, F.

    2012-01-01

    Objective: The purpose of this study was to determine the effect of metaprolol alone and metaprolol plus bromazepam on heart rate and heart rate variability during multi slice computed tomography (MSCT) angiography. Methodology: This was a Double blind randomized controlled trial was conducted at AFIC/NIHD, Rawalpindi, from May 2011 to November 2011. Patients undergoing first MSCT angiography meeting inclusion criteria with heart rates (HR) more than 80 beats/min were included. Patients were randomized in to two groups using random numbers table. Group 1 was administered metaprolol plus placebo while group 2 was administered metaprolol plus bromazepam one hour before the scan. Both groups had scans under strictly similar conditions. HR before and during scan along with heart rate variability (HRV) were recorded. Results: A total of 80 patients were included. Patients mean age was 49 + 13, 57 % were males while 43 % were females. Risk factor profile was similar in both groups. HR reduction in group 1 was 15+ 6.0 and in group 2, was 21+9.0 (p= 0.002). HRV in group 1 was 3.9 + 1.32 and in group 2 was 2.3 + 1.0 (p= 0.003). Group 2 had significantly lower HR and significantly less HRV as compared with group 1. Conclusion: Combination of bromazepam and metaprolol results in significant and further reduction in heart rate and heart rate variability than metaprolol alone. Both drugs can be used together for a better control of heart rate and heart rate variability during MSCT angiography for improving the quality of images. (author)

  16. Heating and cooling rates and their effects upon heart rate in the ...

    African Journals Online (AJOL)

    The heating and cooling rates of adult Chersina angulata were investigated to ascertain whether these tortoises can physiologically alter their rates of heat exchange. In addition, heart rates were recorded to provide an insight into the control of heat exchange. C. angulata heats significantly faster than it cools. Heart rates ...

  17. Heart rate awareness in patients with chronic stable heart failure. A multi-center observational study.

    LENUS (Irish Health Repository)

    Moran, D

    2014-08-23

    We assessed adherence to European Society of Cardiology heart rate guidelines (i.e. heart rates less than 70bpm) in patients with chronic stable heart failure. We also investigated the percent of patients on target doses of rate controlling drugs.

  18. IgG receptor FcγRIIB plays a key role in obesity-induced hypertension.

    Science.gov (United States)

    Sundgren, Nathan C; Vongpatanasin, Wanpen; Boggan, Brigid-Meghan D; Tanigaki, Keiji; Yuhanna, Ivan S; Chambliss, Ken L; Mineo, Chieko; Shaul, Philip W

    2015-02-01

    There is a well-recognized association between obesity, inflammation, and hypertension. Why obesity causes hypertension is poorly understood. We previously demonstrated using a C-reactive protein (CRP) transgenic mouse that CRP induces hypertension that is related to NO deficiency. Our prior work in cultured endothelial cells identified the Fcγ receptor IIB (FcγRIIB) as the receptor for CRP whereby it antagonizes endothelial NO synthase. Recognizing known associations between CRP and obesity and hypertension in humans, in the present study we tested the hypothesis that FcγRIIB plays a role in obesity-induced hypertension in mice. Using radiotelemetry, we first demonstrated that the hypertension observed in transgenic mouse-CRP is mediated by the receptor, indicating that FcγRIIB is capable of modifying blood pressure. We then discovered in a model of diet-induced obesity yielding equal adiposity in all study groups that whereas FcγRIIB(+/+) mice developed obesity-induced hypertension, FcγRIIB(-/-) mice were fully protected. Levels of CRP, the related pentraxin serum amyloid P component which is the CRP-equivalent in mice, and total IgG were unaltered by diet-induced obesity; FcγRIIB expression in endothelium was also unchanged. However, whereas IgG isolated from chow-fed mice had no effect, IgG from high-fat diet-fed mice inhibited endothelial NO synthase in cultured endothelial cells, and this was an FcγRIIB-dependent process. Thus, we have identified a novel role for FcγRIIB in the pathogenesis of obesity-induced hypertension, independent of processes regulating adiposity, and it may entail an IgG-induced attenuation of endothelial NO synthase function. Approaches targeting FcγRIIB may potentially offer new means to treat hypertension in obese individuals. © 2014 American Heart Association, Inc.

  19. The mitochondrial uniporter controls fight or flight heart rate increases.

    Science.gov (United States)

    Wu, Yuejin; Rasmussen, Tyler P; Koval, Olha M; Joiner, Mei-Ling A; Hall, Duane D; Chen, Biyi; Luczak, Elizabeth D; Wang, Qiongling; Rokita, Adam G; Wehrens, Xander H T; Song, Long-Sheng; Anderson, Mark E

    2015-01-20

    Heart rate increases are a fundamental adaptation to physiological stress, while inappropriate heart rate increases are resistant to current therapies. However, the metabolic mechanisms driving heart rate acceleration in cardiac pacemaker cells remain incompletely understood. The mitochondrial calcium uniporter (MCU) facilitates calcium entry into the mitochondrial matrix to stimulate metabolism. We developed mice with myocardial MCU inhibition by transgenic expression of a dominant-negative (DN) MCU. Here, we show that DN-MCU mice had normal resting heart rates but were incapable of physiological fight or flight heart rate acceleration. We found that MCU function was essential for rapidly increasing mitochondrial calcium in pacemaker cells and that MCU-enhanced oxidative phoshorylation was required to accelerate reloading of an intracellular calcium compartment before each heartbeat. Our findings show that MCU is necessary for complete physiological heart rate acceleration and suggest that MCU inhibition could reduce inappropriate heart rate increases without affecting resting heart rate.

  20. Importance of neonatal FcR in regulating the serum half-life of therapeutic proteins containing the Fc domain of human IgG1: a comparative study of the affinity of monoclonal antibodies and Fc-fusion proteins to human neonatal FcR.

    Science.gov (United States)

    Suzuki, Takuo; Ishii-Watabe, Akiko; Tada, Minoru; Kobayashi, Tetsu; Kanayasu-Toyoda, Toshie; Kawanishi, Toru; Yamaguchi, Teruhide

    2010-02-15

    The neonatal FcR (FcRn) binds to the Fc domain of IgG at acidic pH in the endosome and protects IgG from degradation, thereby contributing to the long serum half-life of IgG. To date, more than 20 mAb products and 5 Fc-fusion protein products have received marketing authorization approval in the United States, the European Union, or Japan. Many of these therapeutic proteins have the Fc domain of human IgG1; however, the serum half-lives differ in each protein. To elucidate the role of FcRn in the pharmacokinetics of Fc domain-containing therapeutic proteins, we evaluated the affinity of the clinically used human, humanized, chimeric, or mouse mAbs and Fc-fusion proteins to recombinant human FcRn by surface plasmon resonance analysis. The affinities of these therapeutic proteins to FcRn were found to be closely correlated with the serum half-lives reported from clinical studies, suggesting the important role of FcRn in regulating their serum half-lives. The relatively short serum half-life of Fc-fusion proteins was thought to arise from the low affinity to FcRn. The existence of some mAbs having high affinity to FcRn and a short serum half-life, however, suggested the involvement of other critical factor(s) in determining the serum half-life of such Abs. We further investigated the reason for the relatively low affinity of Fc-fusion proteins to FcRn and suggested the possibility that the receptor domain of Fc-fusion protein influences the structural environment of the FcRn binding region but not of the FcgammaRI binding region of the Fc domain.

  1. Arduino-based noise robust online heart-rate detection.

    Science.gov (United States)

    Das, Sangita; Pal, Saurabh; Mitra, Madhuchhanda

    2017-04-01

    This paper introduces a noise robust real time heart rate detection system from electrocardiogram (ECG) data. An online data acquisition system is developed to collect ECG signals from human subjects. Heart rate is detected using window-based autocorrelation peak localisation technique. A low-cost Arduino UNO board is used to implement the complete automated process. The performance of the system is compared with PC-based heart rate detection technique. Accuracy of the system is validated through simulated noisy ECG data with various levels of signal to noise ratio (SNR). The mean percentage error of detected heart rate is found to be 0.72% for the noisy database with five different noise levels.

  2. Heart rate variability interventions for concussion and rehabilitation

    OpenAIRE

    Conder, Robert L.; Conder, Alanna A.

    2014-01-01

    The study of Heart Rate Variability (HRV) has emerged as an essential component of cardiovascular health, as well as a physiological mechanism by which one can increase the interactive communication between the cardiac and the neurocognitive systems (i.e., the body and the brain). It is well-established that lack of heart rate variability implies cardiopathology, morbidity, reduced quality-of-life, and precipitous mortality. On the positive, optimal heart rate variability has been associated ...

  3. Heart Rate Monitoring in Team Sports—A Conceptual Framework for Contextualizing Heart Rate Measures for Training and Recovery Prescription

    Directory of Open Access Journals (Sweden)

    Christoph Schneider

    2018-05-01

    Full Text Available A comprehensive monitoring of fitness, fatigue, and performance is crucial for understanding an athlete's individual responses to training to optimize the scheduling of training and recovery strategies. Resting and exercise-related heart rate measures have received growing interest in recent decades and are considered potentially useful within multivariate response monitoring, as they provide non-invasive and time-efficient insights into the status of the autonomic nervous system (ANS and aerobic fitness. In team sports, the practical implementation of athlete monitoring systems poses a particular challenge due to the complex and multidimensional structure of game demands and player and team performance, as well as logistic reasons, such as the typically large number of players and busy training and competition schedules. In this regard, exercise-related heart rate measures are likely the most applicable markers, as they can be routinely assessed during warm-ups using short (3–5 min submaximal exercise protocols for an entire squad with common chest strap-based team monitoring devices. However, a comprehensive and meaningful monitoring of the training process requires the accurate separation of various types of responses, such as strain, recovery, and adaptation, which may all affect heart rate measures. Therefore, additional information on the training context (such as the training phase, training load, and intensity distribution combined with multivariate analysis, which includes markers of (perceived wellness and fatigue, should be considered when interpreting changes in heart rate indices. The aim of this article is to outline current limitations of heart rate monitoring, discuss methodological considerations of univariate and multivariate approaches, illustrate the influence of different analytical concepts on assessing meaningful changes in heart rate responses, and provide case examples for contextualizing heart rate measures using

  4. Heart Rate Monitoring in Team Sports-A Conceptual Framework for Contextualizing Heart Rate Measures for Training and Recovery Prescription.

    Science.gov (United States)

    Schneider, Christoph; Hanakam, Florian; Wiewelhove, Thimo; Döweling, Alexander; Kellmann, Michael; Meyer, Tim; Pfeiffer, Mark; Ferrauti, Alexander

    2018-01-01

    A comprehensive monitoring of fitness, fatigue, and performance is crucial for understanding an athlete's individual responses to training to optimize the scheduling of training and recovery strategies. Resting and exercise-related heart rate measures have received growing interest in recent decades and are considered potentially useful within multivariate response monitoring, as they provide non-invasive and time-efficient insights into the status of the autonomic nervous system (ANS) and aerobic fitness. In team sports, the practical implementation of athlete monitoring systems poses a particular challenge due to the complex and multidimensional structure of game demands and player and team performance, as well as logistic reasons, such as the typically large number of players and busy training and competition schedules. In this regard, exercise-related heart rate measures are likely the most applicable markers, as they can be routinely assessed during warm-ups using short (3-5 min) submaximal exercise protocols for an entire squad with common chest strap-based team monitoring devices. However, a comprehensive and meaningful monitoring of the training process requires the accurate separation of various types of responses, such as strain, recovery, and adaptation, which may all affect heart rate measures. Therefore, additional information on the training context (such as the training phase, training load, and intensity distribution) combined with multivariate analysis, which includes markers of (perceived) wellness and fatigue, should be considered when interpreting changes in heart rate indices. The aim of this article is to outline current limitations of heart rate monitoring, discuss methodological considerations of univariate and multivariate approaches, illustrate the influence of different analytical concepts on assessing meaningful changes in heart rate responses, and provide case examples for contextualizing heart rate measures using simple heuristics. To

  5. The neonatal Fc receptor, FcRn, as a target for drug delivery and therapy.

    Science.gov (United States)

    Sockolosky, Jonathan T; Szoka, Francis C

    2015-08-30

    Immunoglobulin G (IgG)-based drugs are arguably the most successful class of protein therapeutics due in part to their remarkably long blood circulation. This arises from IgG interaction with the neonatal Fc receptor, FcRn. FcRn is the central regulator of IgG and albumin homeostasis throughout life and is increasingly being recognized as an important player in autoimmune disease, mucosal immunity, and tumor immune surveillance. Various engineering approaches that hijack or disrupt the FcRn-mediated transport pathway have been devised to develop long-lasting and non-invasive protein therapeutics, protein subunit vaccines, and therapeutics for treatment of autoimmune and infectious disease. In this review, we highlight the diverse biological functions of FcRn, emerging therapeutic opportunities, as well as the associated challenges of targeting FcRn for drug delivery and disease therapy. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Heart rate measurement based on face video sequence

    Science.gov (United States)

    Xu, Fang; Zhou, Qin-Wu; Wu, Peng; Chen, Xing; Yang, Xiaofeng; Yan, Hong-jian

    2015-03-01

    This paper proposes a new non-contact heart rate measurement method based on photoplethysmography (PPG) theory. With this method we can measure heart rate remotely with a camera and ambient light. We collected video sequences of subjects, and detected remote PPG signals through video sequences. Remote PPG signals were analyzed with two methods, Blind Source Separation Technology (BSST) and Cross Spectral Power Technology (CSPT). BSST is a commonly used method, and CSPT is used for the first time in the study of remote PPG signals in this paper. Both of the methods can acquire heart rate, but compared with BSST, CSPT has clearer physical meaning, and the computational complexity of CSPT is lower than that of BSST. Our work shows that heart rates detected by CSPT method have good consistency with the heart rates measured by a finger clip oximeter. With good accuracy and low computational complexity, the CSPT method has a good prospect for the application in the field of home medical devices and mobile health devices.

  7. Power spectral analysis of heart rate in hyperthyroidism.

    Science.gov (United States)

    Cacciatori, V; Bellavere, F; Pezzarossa, A; Dellera, A; Gemma, M L; Thomaseth, K; Castello, R; Moghetti, P; Muggeo, M

    1996-08-01

    The aim of the present study was to evaluate the impact of hyperthyroidism on the cardiovascular system by separately analyzing the sympathetic and parasympathetic influences on heart rate. Heart rate variability was evaluated by autoregressive power spectral analysis. This method allows a reliable quantification of the low frequency (LF) and high frequency (HF) components of the heart rate power spectral density; these are considered to be under mainly sympathetic and pure parasympathetic control, respectively. In 10 newly diagnosed untreated hyperthyroid patients with Graves' disease, we analyzed power spectral density of heart rate cyclic variations at rest, while lying, and while standing. In addition, heart rate variations during deep breathing, lying and standing, and Valsalva's maneuver were analyzed. The results were compared to those obtained from 10 age-, sex-, and body mass index-matched control subjects. In 8 hyperthyroid patients, the same evaluation was repeated after the induction of stable euthyroidism by methimazole. Heart rate power spectral analysis showed a sharp reduction of HF components in hyperthyroid subjects compared to controls [lying, 13.3 +/- 4.1 vs. 32.0 +/- 5.6 normalized units (NU; P hyperthyroid subjects while both lying (11.3 +/- 4.5 vs. 3.5 +/- 1.1; P hyperthyroid patients than in controls (1.12 +/- 0.03 vs. 1.31 +/- 0.04; P activity and, thus, a relative hypersympathetic tone.

  8. Heart rate response to hypoxic exercise

    DEFF Research Database (Denmark)

    Lundby, C; Møller, P; Kanstrup, I L

    2001-01-01

    progressively decreased the maximal heart rate from day 1 and onwards; also, hypoxia by itself increased plasma noradrenaline levels after maximal exercise. Domperidone further increased maximal noradrenaline concentrations, but had no effect on maximal heart rate. On each study day at altitude, oxygen......This study examined the effects of dopamine D(2)-receptor blockade on the early decrease in maximal heart rate at high altitude (4559 m). We also attempted to clarify the time-dependent component of this reduction and the extent to which it is reversed by oxygen breathing. Twelve subjects performed...... two consecutive maximal exercise tests, without and with oxygen supplementation respectively, at sea level and after 1, 3 and 5 days at altitude. On each study day, domperidone (30 mg; n=6) or no medication (n=6) was given 1 h before the first exercise session. Compared with sea level, hypoxia...

  9. The heart field effect: Synchronization of healer-subject heart rates in energy therapy.

    Science.gov (United States)

    Bair, Christine Caldwell

    2008-01-01

    Recent health research has focused on subtle energy and vibrational frequency as key components of health and healing. In particular, intentional direction of bioenergy is receiving increasing scientific attention. This study investigates the effect of the healer's electromagnetic (EM) heart field upon subjects during energy healing as measured by synchronization of heart rates and scores on a Subjective Units of Distress (SUD) scale and a Profile of Mood States (POMS) inventory. A nonequivalent pretest-posttest design was used based on heart rate comparisons between healer and subject and correlated with pre-and posttest SUD and POMS scores. Subjects included those who sat within the 3- to 4-foot "strong" range of the independent variable, the healer's heart field, while performing self-application of WHEE (the wholistic hybrid derived from EMDR [eye movement desensitization and reprocessing], and EFT [emotional freedom technique]), a meridian-based tapping technique (n=50); and those who performed the same process beyond the 15- to 18-foot range of the healer's EM heart field (n=41). The dependent variables were heart rate, SUD, and POMS inventory. All subjects completed these measures within 1 hour. Study results showed statistically significant heart-rate synchronization with the intervention population. In addition, SUD and POMS scores demonstrated considerably more improvement than in the control population, indicating additional benefit beyond the meridian-based therapies, such as WHEE, alone. Additional findings and future research recommendations are presented in this article.

  10. Learning by Heart: Students Use Heart Rate Patterns To Identify Nervous System Imbalances.

    Science.gov (United States)

    Ackerly, Spafford C.

    2001-01-01

    Introduces a science unit on heart rate variability (HVR) patterns. Uses spectral analysis to determine the effects of environmental stimulants such as music and emotional stress on heart rate. Observes relaxation techniques and their effects on the autonomous nervous system. (Contains 12 references.) (YDS)

  11. [Resonance hypothesis of heart rate variability origin].

    Science.gov (United States)

    Sheĭkh-Zade, Iu R; Mukhambetaliev, G Kh; Cherednik, I L

    2009-09-01

    A hypothesis is advanced of the heart rate variability being subjected to beat-to-beat regulation of cardiac cycle duration in order to ensure the resonance interaction between respiratory and own fluctuation of the arterial system volume for minimization of power expenses of cardiorespiratory system. Myogenic, parasympathetic and sympathetic machanisms of heart rate variability are described.

  12. Accuracy of Heart Rate Watches: Implications for Weight Management.

    Directory of Open Access Journals (Sweden)

    Matthew P Wallen

    Full Text Available Wrist-worn monitors claim to provide accurate measures of heart rate and energy expenditure. People wishing to lose weight use these devices to monitor energy balance, however the accuracy of these devices to measure such parameters has not been established.To determine the accuracy of four wrist-worn devices (Apple Watch, Fitbit Charge HR, Samsung Gear S and Mio Alpha to measure heart rate and energy expenditure at rest and during exercise.Twenty-two healthy volunteers (50% female; aged 24 ± 5.6 years completed ~1-hr protocols involving supine and seated rest, walking and running on a treadmill and cycling on an ergometer. Data from the devices collected during the protocol were compared with reference methods: electrocardiography (heart rate and indirect calorimetry (energy expenditure.None of the devices performed significantly better overall, however heart rate was consistently more accurate than energy expenditure across all four devices. Correlations between the devices and reference methods were moderate to strong for heart rate (0.67-0.95 [0.35 to 0.98] and weak to strong for energy expenditure (0.16-0.86 [-0.25 to 0.95]. All devices underestimated both outcomes compared to reference methods. The percentage error for heart rate was small across the devices (range: 1-9% but greater for energy expenditure (9-43%. Similarly, limits of agreement were considerably narrower for heart rate (ranging from -27.3 to 13.1 bpm than energy expenditure (ranging from -266.7 to 65.7 kcals across devices.These devices accurately measure heart rate. However, estimates of energy expenditure are poor and would have implications for people using these devices for weight loss.

  13. Accuracy of Heart Rate Watches: Implications for Weight Management.

    Science.gov (United States)

    Wallen, Matthew P; Gomersall, Sjaan R; Keating, Shelley E; Wisløff, Ulrik; Coombes, Jeff S

    2016-01-01

    Wrist-worn monitors claim to provide accurate measures of heart rate and energy expenditure. People wishing to lose weight use these devices to monitor energy balance, however the accuracy of these devices to measure such parameters has not been established. To determine the accuracy of four wrist-worn devices (Apple Watch, Fitbit Charge HR, Samsung Gear S and Mio Alpha) to measure heart rate and energy expenditure at rest and during exercise. Twenty-two healthy volunteers (50% female; aged 24 ± 5.6 years) completed ~1-hr protocols involving supine and seated rest, walking and running on a treadmill and cycling on an ergometer. Data from the devices collected during the protocol were compared with reference methods: electrocardiography (heart rate) and indirect calorimetry (energy expenditure). None of the devices performed significantly better overall, however heart rate was consistently more accurate than energy expenditure across all four devices. Correlations between the devices and reference methods were moderate to strong for heart rate (0.67-0.95 [0.35 to 0.98]) and weak to strong for energy expenditure (0.16-0.86 [-0.25 to 0.95]). All devices underestimated both outcomes compared to reference methods. The percentage error for heart rate was small across the devices (range: 1-9%) but greater for energy expenditure (9-43%). Similarly, limits of agreement were considerably narrower for heart rate (ranging from -27.3 to 13.1 bpm) than energy expenditure (ranging from -266.7 to 65.7 kcals) across devices. These devices accurately measure heart rate. However, estimates of energy expenditure are poor and would have implications for people using these devices for weight loss.

  14. Simultaneous measurement of instantaneous heart rate and chest wall plethysmography in short-term, metronome guided heart rate variability studies: suitability for assessment of autonomic dysfunction.

    Science.gov (United States)

    Perring, S; Jones, E

    2003-08-01

    Instantaneous heart rate and chest wall motion were measured using a 3-lead ECG and an air pressure chest wall plethysmography system. Chest wall plethysmography traces were found to accurately represent the breathing pattern as measured by spirometry (average correlation coefficient 0.944); though no attempt was made to calibrate plethysmography voltage output to tidal volume. Simultaneous measurements of heart rate and chest wall motion were made for short periods under metronome guided breathing at 6 breaths per minute. The average peak to trough heart rate change per breath cycle (AVEMAX) and maximum correlation between heart rate and breathing cycle (HRBRCORR) were measured. Studies of 44 normal volunteers indicated clear inverse correlation of heart rate variability parameters with age (AVEMAX R = -0.502, P < 0.001) but no significant change in HRBRCORR with age (R = -0.115). Comparison of normal volunteers with diabetics with no history of symptoms associated with autonomic failure indicated significant lower heart rate variability in diabetics (P = 0.005 for AVEMAX) and significantly worse correlation between heart rate and breathing (P < 0.001 for HRBRCORR). Simultaneous measurement of heart rate and breathing offers the possibility of more sensitive diagnosis of autonomic failure in a simple bedside test and gives further insight into the nature of cardio-ventilatory coupling.

  15. Field flow fractionation for assessing neonatal Fc receptor and Fcγ receptor binding to monoclonal antibodies in solution.

    Science.gov (United States)

    Pollastrini, Joey; Dillon, Thomas M; Bondarenko, Pavel; Chou, Robert Y-T

    2011-07-01

    Analysis of the strength and stoichiometry of immunoglobulin G (IgG) binding to neonatal Fc receptor (FcRn) and Fcγ receptor (FcγR) is important for evaluating the pharmacokinetics and effector functions of therapeutic monoclonal antibody (mAb) products, respectively. The current standard for assessing FcγR and FcRn binding is composed of cell-based and surface plasmon resonance (SPR) assays. In this work, asymmetrical flow field flow fractionation (AF4) was evaluated to establish the true stoichiometry of IgG binding in solution. AF4 and liquid chromatography-mass spectrometry (LC-MS) were applied to directly observe IgG/FcγR and IgG/FcRn complexes, which were not observed using nonequilibrium size exclusion chromatography (SEC) analysis. Human serum albumin (HSA), an abundant component of human blood and capable of binding FcRn, was studied in combination with FcRn and IgG. AF4 demonstrated that the majority of large complexes of IgG/FcRn/HSA were at an approximate 1:2:1 molar ratio. In addition, affinity measurements of the complex were performed in the sub-micromolar affinity range. A significant decrease in binding was detected for IgG molecules with increased oxidation in the Fc region. AF4 was useful in detecting weak binding between full-length IgG/Fc fragments and Fc receptors and the effect of chemical modifications on binding. AF4 is a useful technique in the assessment of mAb product quality attributes. Copyright © 2011 Elsevier Inc. All rights reserved.

  16. Dicty_cDB: FC-BS11 [Dicty_cDB

    Lifescience Database Archive (English)

    Full Text Available FC (Link to library) FC-BS11 (Link to dictyBase) - - - Contig-U16517-1 FC-BS11Z (Li...nk to Original site) - - FC-BS11Z 683 - - - - Show FC-BS11 Library FC (Link to library) Clone ID FC-BS11 (Li.../dictycdb.biol.tsukuba.ac.jp/CSM/FC/FC-BS/FC-BS11Q.Seq.d/ Representative seq. ID FC-BS...11Z (Link to Original site) Representative DNA sequence >FC-BS11 (FC-BS11Q) /CSM/FC/FC-BS/FC-BS11Q.Seq....s producing significant alignments: (bits) Value FC-BS11 (FC-BS11Q) /CSM/FC/FC-BS/FC-BS

  17. Dicty_cDB: FC-BS10 [Dicty_cDB

    Lifescience Database Archive (English)

    Full Text Available FC (Link to library) FC-BS10 (Link to dictyBase) - - - Contig-U16283-1 FC-BS10Z (Li...nk to Original site) - - FC-BS10Z 720 - - - - Show FC-BS10 Library FC (Link to library) Clone ID FC-BS10 (Li.../dictycdb.biol.tsukuba.ac.jp/CSM/FC/FC-BS/FC-BS10Q.Seq.d/ Representative seq. ID FC-BS...10Z (Link to Original site) Representative DNA sequence >FC-BS10 (FC-BS10Q) /CSM/FC/FC-BS/FC-BS10Q.Seq....E Sequences producing significant alignments: (bits) Value FC-BS10 (FC-BS10Q) /CSM/FC/FC-BS/FC-BS10Q.Seq.d/

  18. Dicty_cDB: FC-BS21 [Dicty_cDB

    Lifescience Database Archive (English)

    Full Text Available FC (Link to library) FC-BS21 (Link to dictyBase) - - - Contig-U15764-1 FC-BS21Z (Li...nk to Original site) - - FC-BS21Z 723 - - - - Show FC-BS21 Library FC (Link to library) Clone ID FC-BS21 (Li.../dictycdb.biol.tsukuba.ac.jp/CSM/FC/FC-BS/FC-BS21Q.Seq.d/ Representative seq. ID FC-BS...21Z (Link to Original site) Representative DNA sequence >FC-BS21 (FC-BS21Q) /CSM/FC/FC-BS/FC-BS21Q.Seq.... Score E Sequences producing significant alignments: (bits) Value FC-BS21 (FC-BS21Q) /CSM/FC/FC-BS/FC-BS21Q.

  19. Dicty_cDB: FC-BS19 [Dicty_cDB

    Lifescience Database Archive (English)

    Full Text Available FC (Link to library) FC-BS19 (Link to dictyBase) - - - Contig-U16583-1 FC-BS19E (Li...nk to Original site) - - - - - - FC-BS19E 604 Show FC-BS19 Library FC (Link to library) Clone ID FC-BS19 (Li.../dictycdb.biol.tsukuba.ac.jp/CSM/FC/FC-BS/FC-BS19Q.Seq.d/ Representative seq. ID FC-BS...19E (Link to Original site) Representative DNA sequence >FC-BS19 (FC-BS19Q) /CSM/FC/FC-BS/FC-BS19Q.Seq....E Sequences producing significant alignments: (bits) Value FC-BS19 (FC-BS19Q) /CSM/FC/FC-BS/FC-BS19Q.Seq.d/

  20. Dicty_cDB: FC-AI01 [Dicty_cDB

    Lifescience Database Archive (English)

    Full Text Available FC (Link to library) FC-AI01 (Link to dictyBase) - - - Contig-U15592-1 FC-AI01E (Li...nk to Original site) - - - - - - FC-AI01E 307 Show FC-AI01 Library FC (Link to library) Clone ID FC-AI01 (Li.../dictycdb.biol.tsukuba.ac.jp/CSM/FC/FC-AI/FC-AI01Q.Seq.d/ Representative seq. ID FC-AI...01E (Link to Original site) Representative DNA sequence >FC-AI01 (FC-AI01Q) /CSM/FC/FC-AI/FC-AI01Q.Seq....uences producing significant alignments: (bits) Value FC-AI01 (FC-AI01Q) /CSM/FC/FC-AI/FC-AI01Q.Seq.d/ 68 8e

  1. Dicty_cDB: FC-BS09 [Dicty_cDB

    Lifescience Database Archive (English)

    Full Text Available FC (Link to library) FC-BS09 (Link to dictyBase) - - - Contig-U16215-1 FC-BS09Z (Li...nk to Original site) - - FC-BS09Z 626 - - - - Show FC-BS09 Library FC (Link to library) Clone ID FC-BS09 (Li.../dictycdb.biol.tsukuba.ac.jp/CSM/FC/FC-BS/FC-BS09Q.Seq.d/ Representative seq. ID FC-BS...09Z (Link to Original site) Representative DNA sequence >FC-BS09 (FC-BS09Q) /CSM/FC/FC-BS/FC-BS09Q.Seq....ignments: (bits) Value SSF360 (SSF360Q) /CSM/SS/SSF3-C/SSF360Q.Seq.d/ 854 0.0 FC-BS09 (FC-BS09Q) /CSM/FC/FC-BS/FC-BS

  2. Dicty_cDB: FC-AI13 [Dicty_cDB

    Lifescience Database Archive (English)

    Full Text Available FC (Link to library) FC-AI13 (Link to dictyBase) - - - Contig-U16263-1 FC-AI13F (Li...nk to Original site) FC-AI13F 507 - - - - - - Show FC-AI13 Library FC (Link to library) Clone ID FC-AI13 (Li.../dictycdb.biol.tsukuba.ac.jp/CSM/FC/FC-AI/FC-AI13Q.Seq.d/ Representative seq. ID FC-AI...13F (Link to Original site) Representative DNA sequence >FC-AI13 (FC-AI13Q) /CSM/FC/FC-AI/FC-AI13Q.Seq....nificant alignments: (bits) Value FC-AI13 (FC-AI13Q) /CSM/FC/FC-AI/FC-AI13Q.Seq.d/ 963 0.0 VSA730 (VSA730Q)

  3. Heart Rate Fragmentation: A Symbolic Dynamical Approach

    Directory of Open Access Journals (Sweden)

    Madalena D. Costa

    2017-11-01

    Full Text Available Background: We recently introduced the concept of heart rate fragmentation along with a set of metrics for its quantification. The term was coined to refer to an increase in the percentage of changes in heart rate acceleration sign, a dynamical marker of a type of anomalous variability. The effort was motivated by the observation that fragmentation, which is consistent with the breakdown of the neuroautonomic-electrophysiologic control system of the sino-atrial node, could confound traditional short-term analysis of heart rate variability.Objective: The objectives of this study were to: (1 introduce a symbolic dynamical approach to the problem of quantifying heart rate fragmentation; (2 evaluate how the distribution of the different dynamical patterns (“words” varied with the participants' age in a group of healthy subjects and patients with coronary artery disease (CAD; and (3 quantify the differences in the fragmentation patterns between the two sample populations.Methods: The symbolic dynamical method employed here was based on a ternary map of the increment NN interval time series and on the analysis of the relative frequency of symbolic sequences (words with a pre-defined set of features. We analyzed annotated, open-access Holter databases of healthy subjects and patients with CAD, provided by the University of Rochester Telemetric and Holter ECG Warehouse (THEW.Results: The degree of fragmentation was significantly higher in older individuals than in their younger counterparts. However, the fragmentation patterns were different in the two sample populations. In healthy subjects, older age was significantly associated with a higher percentage of transitions from acceleration/deceleration to zero acceleration and vice versa (termed “soft” inflection points. In patients with CAD, older age was also significantly associated with higher percentages of frank reversals in heart rate acceleration (transitions from acceleration to

  4. Dicty_cDB: FC-BR23 [Dicty_cDB

    Lifescience Database Archive (English)

    Full Text Available FC (Link to library) FC-BR23 (Link to dictyBase) - - - Contig-U15008-1 FC-BR23Z (Li...nk to Original site) - - FC-BR23Z 641 - - - - Show FC-BR23 Library FC (Link to library) Clone ID FC-BR23 (Li.../dictycdb.biol.tsukuba.ac.jp/CSM/FC/FC-BR/FC-BR23Q.Seq.d/ Representative seq. ID FC-BR2...3Z (Link to Original site) Representative DNA sequence >FC-BR23 (FC-BR23Q) /CSM/FC/FC-BR/FC-BR23Q.Seq....9 0.0 SLA211 (SLA211Q) /CSM/SL/SLA2-A/SLA211Q.Seq.d/ 1029 0.0 FC-BR23 (FC-BR23Q) /CSM/FC/FC-BR/FC-BR2

  5. Dicty_cDB: FC-BS14 [Dicty_cDB

    Lifescience Database Archive (English)

    Full Text Available FC (Link to library) FC-BS14 (Link to dictyBase) - - - Contig-U16399-1 FC-BS14E (Li...nk to Original site) - - - - - - FC-BS14E 534 Show FC-BS14 Library FC (Link to library) Clone ID FC-BS14 (Li.../dictycdb.biol.tsukuba.ac.jp/CSM/FC/FC-BS/FC-BS14Q.Seq.d/ Representative seq. ID FC-BS...14E (Link to Original site) Representative DNA sequence >FC-BS14 (FC-BS14Q) /CSM/FC/FC-BS/FC-BS14Q.Seq.... vs CSM-cDNA Score E Sequences producing significant alignments: (bits) Value FC-BS14 (FC-BS

  6. Dicty_cDB: FC-AI17 [Dicty_cDB

    Lifescience Database Archive (English)

    Full Text Available FC (Link to library) FC-AI17 (Link to dictyBase) - - - Contig-U15690-1 FC-AI17P (Li...nk to Original site) FC-AI17F 587 FC-AI17Z 626 FC-AI17P 1212 - - Show FC-AI17 Library FC (Link to library) Clone ID FC-AI...nal site URL http://dictycdb.biol.tsukuba.ac.jp/CSM/FC/FC-AI/FC-AI17Q.Seq.d/ Representative seq. ID FC-AI...17P (Link to Original site) Representative DNA sequence >FC-AI17 (FC-AI17Q) /CSM/FC/FC-AI/FC-AI...slated Amino Acid sequence ANIATVGDFLKADTVVPKMIITYNKRKQGTDYLKAVIGPILSNVIKQELNLELKPNLVYA AIISEQEIRTGEKSTLDRNV

  7. Dicty_cDB: FC-AI18 [Dicty_cDB

    Lifescience Database Archive (English)

    Full Text Available FC (Link to library) FC-AI18 (Link to dictyBase) - - - Contig-U15590-1 FC-AI18P (Li...nk to Original site) FC-AI18F 621 FC-AI18Z 703 FC-AI18P 1324 - - Show FC-AI18 Library FC (Link to library) Clone ID FC-AI...nal site URL http://dictycdb.biol.tsukuba.ac.jp/CSM/FC/FC-AI/FC-AI18Q.Seq.d/ Representative seq. ID FC-AI...18P (Link to Original site) Representative DNA sequence >FC-AI18 (FC-AI18Q) /CSM/FC/FC-AI/FC-AI...AVWPLIPGYERA DGEKQYPVAAMLCNFTKPTPTTPSLLTHDEVVTFFHEFGHVMHNMSTKVHYSMFSGTSVE RDFVECPSQLFEFWCWNKDVLVNKLSGHXKDHSKKLPTDLVERMIAAKNLNVAI

  8. Dicty_cDB: FC-AI04 [Dicty_cDB

    Lifescience Database Archive (English)

    Full Text Available FC (Link to library) FC-AI04 (Link to dictyBase) - - - Contig-U15121-1 FC-AI04E (Li...nk to Original site) - - - - - - FC-AI04E 772 Show FC-AI04 Library FC (Link to library) Clone ID FC-AI04 (Li.../dictycdb.biol.tsukuba.ac.jp/CSM/FC/FC-AI/FC-AI04Q.Seq.d/ Representative seq. ID FC-AI...04E (Link to Original site) Representative DNA sequence >FC-AI04 (FC-AI04Q) /CSM/FC/FC-AI/FC-AI04Q.Seq....qvnkhqqvvtktvsd vlvphqvhnqvfphipqqmtlvnkhqpvvtktvsdvlvphqvhnqvfphtpqlkiqvylq vfqvvvvtiisai

  9. Dicty_cDB: FC-AI10 [Dicty_cDB

    Lifescience Database Archive (English)

    Full Text Available FC (Link to library) FC-AI10 (Link to dictyBase) - - - Contig-U16270-1 FC-AI10F (Li...nk to Original site) FC-AI10F 405 - - - - - - Show FC-AI10 Library FC (Link to library) Clone ID FC-AI10 (Li.../dictycdb.biol.tsukuba.ac.jp/CSM/FC/FC-AI/FC-AI10Q.Seq.d/ Representative seq. ID FC-AI...10F (Link to Original site) Representative DNA sequence >FC-AI10 (FC-AI10Q) /CSM/FC/FC-AI/FC-AI10Q.Seq.... sequence RKKRKSDYTSFSTYIHKLLKQITPPTNAKSNEKGDRKFTISSKAMSVMNSFVHDIFDRIA TEASGLAKKKKRQTLHSRDIQVAVRIILTGELAXHAI

  10. Dicty_cDB: FC-AI23 [Dicty_cDB

    Lifescience Database Archive (English)

    Full Text Available FC (Link to library) FC-AI23 (Link to dictyBase) - - - Contig-U15308-1 FC-AI23Z (Li...nk to Original site) - - FC-AI23Z 603 - - - - Show FC-AI23 Library FC (Link to library) Clone ID FC-AI23 (Li.../dictycdb.biol.tsukuba.ac.jp/CSM/FC/FC-AI/FC-AI23Q.Seq.d/ Representative seq. ID FC-AI...23Z (Link to Original site) Representative DNA sequence >FC-AI23 (FC-AI23Q) /CSM/FC/FC-AI/FC-AI23Q.Seq....LNTLAKKNEQVVEGEILAKQLTGVTAEELSEFKACFSHFDKDN DNKLNRLEFSSCLKSIGDELTEEQLNQVISKIDTDGNGTISFEEFIDYMVSSRKGTDSVE STKAAFKVMAEDKDFITEAQIRAAI

  11. Dicty_cDB: FC-AI05 [Dicty_cDB

    Lifescience Database Archive (English)

    Full Text Available FC (Link to library) FC-AI05 (Link to dictyBase) - - - Contig-U15516-1 FC-AI05E (Li...nk to Original site) - - - - - - FC-AI05E 1189 Show FC-AI05 Library FC (Link to library) Clone ID FC-AI05 (L...//dictycdb.biol.tsukuba.ac.jp/CSM/FC/FC-AI/FC-AI05Q.Seq.d/ Representative seq. ID FC-AI...05E (Link to Original site) Representative DNA sequence >FC-AI05 (FC-AI05Q) /CSM/FC/FC-AI/FC-AI05Q.Seq...KIVGEASLKNKGKMSRVLAAKAALSARFD ALCEVSDTSYGIAYKGAVDRRAAAIEGREVRKSLNAVKPEKSGNVAKYDHTKSATTNTTR DVATKSSKESSIKQEKQ

  12. Dicty_cDB: FC-AI21 [Dicty_cDB

    Lifescience Database Archive (English)

    Full Text Available FC (Link to library) FC-AI21 (Link to dictyBase) - - - Contig-U16254-1 FC-AI21Z (Li...nk to Original site) - - FC-AI21Z 696 - - - - Show FC-AI21 Library FC (Link to library) Clone ID FC-AI21 (Li.../dictycdb.biol.tsukuba.ac.jp/CSM/FC/FC-AI/FC-AI21Q.Seq.d/ Representative seq. ID FC-AI...21Z (Link to Original site) Representative DNA sequence >FC-AI21 (FC-AI21Q) /CSM/FC/FC-AI/FC-AI21Q.Seq....YPGYMYTDLSTIYERAGRIQGRNGSITQI PILTMPNDDITHPIPDLTGYITEGQIFIDRQINNRQIYPPINVLPSLSRLMKSAI

  13. Heart rate variability - a historical perspective.

    Science.gov (United States)

    Billman, George E

    2011-01-01

    Heart rate variability (HRV), the beat-to-beat variation in either heart rate or the duration of the R-R interval - the heart period, has become a popular clinical and investigational tool. The temporal fluctuations in heart rate exhibit a marked synchrony with respiration (increasing during inspiration and decreasing during expiration - the so called respiratory sinus arrhythmia, RSA) and are widely believed to reflect changes in cardiac autonomic regulation. Although the exact contributions of the parasympathetic and the sympathetic divisions of the autonomic nervous system to this variability are controversial and remain the subject of active investigation and debate, a number of time and frequency domain techniques have been developed to provide insight into cardiac autonomic regulation in both health and disease. It is the purpose of this essay to provide an historical overview of the evolution in the concept of HRV. Briefly, pulse rate was first measured by ancient Greek physicians and scientists. However, it was not until the invention of the "Physician's Pulse Watch" (a watch with a second hand that could be stopped) in 1707 that changes in pulse rate could be accurately assessed. The Rev. Stephen Hales (1733) was the first to note that pulse varied with respiration and in 1847 Carl Ludwig was the first to record RSA. With the measurement of the ECG (1895) and advent of digital signal processing techniques in the 1960s, investigation of HRV and its relationship to health and disease has exploded. This essay will conclude with a brief description of time domain, frequency domain, and non-linear dynamic analysis techniques (and their limitations) that are commonly used to measure HRV.

  14. Revisiting Field Capacity (FC: variation of definition of FC and its estimation from pedotransfer functions

    Directory of Open Access Journals (Sweden)

    Theophilo Benedicto Ottoni Filho

    2014-12-01

    Full Text Available Taking into account the nature of the hydrological processes involved in in situ measurement of Field Capacity (FC, this study proposes a variation of the definition of FC aiming not only at minimizing the inadequacies of its determination, but also at maintaining its original, practical meaning. Analysis of FC data for 22 Brazilian soils and additional FC data from the literature, all measured according to the proposed definition, which is based on a 48-h drainage time after infiltration by shallow ponding, indicates a weak dependency on the amount of infiltrated water, antecedent moisture level, soil morphology, and the level of the groundwater table, but a strong dependency on basic soil properties. The dependence on basic soil properties allowed determination of FC of the 22 soil profiles by pedotransfer functions (PTFs using the input variables usually adopted in prediction of soil water retention. Among the input variables, soil moisture content θ (6 kPa had the greatest impact. Indeed, a linear PTF based only on it resulted in an FC with a root mean squared residue less than 0.04 m³ m-3 for most soils individually. Such a PTF proved to be a better FC predictor than the traditional method of using moisture content at an arbitrary suction. Our FC data were compatible with an equivalent and broader USA database found in the literature, mainly for medium-texture soil samples. One reason for differences between FCs of the two data sets of fine-textured soils is due to their different drainage times. Thus, a standardized procedure for in situ determination of FC is recommended.

  15. Monitoring nocturnal heart rate with bed sensor.

    Science.gov (United States)

    Migliorini, M; Kortelainen, J M; Pärkkä, J; Tenhunen, M; Himanen, S L; Bianchi, A M

    2014-01-01

    This article is part of the Focus Theme of Methods of Information in Medicine on "Biosignal Interpretation: Advanced Methods for Studying Cardiovascular and Respiratory Systems". The aim of this study is to assess the reliability of the estimated Nocturnal Heart Rate (HR), recorded through a bed sensor, compared with the one obtained from standard electrocardiography (ECG). Twenty-eight sleep deprived patients were recorded for one night each through matrix of piezoelectric sensors, integrated into the mattress, through polysomnography (PSG) simultaneously. The two recording methods have been compared in terms of signal quality and differences in heart beat detection. On average, coverage of 92.7% of the total sleep time was obtained for the bed sensor, testifying the good quality of the recordings. The average beat-to-beat error of the inter-beat intervals was 1.06%. These results suggest a good overall signal quality, however, considering fast heart rates (HR > 100 bpm), performances were worse: in fact, the sensitivity in the heart beat detection was 28.4% while the false positive rate was 3.8% which means that a large amount of fast beats were not detected. The accuracy of the measurements made using the bed sensor has less than 10% of failure rate especially in periods with HR lower than 70 bpm. For fast heart beats the uncertainty increases. This can be explained by the change in morphology of the bed sensor signal in correspondence of a higher HR.

  16. Dicty_cDB: FC-AI03 [Dicty_cDB

    Lifescience Database Archive (English)

    Full Text Available FC (Link to library) FC-AI03 (Link to dictyBase) - - - Contig-U15833-1 FC-AI03P (Li...nk to Original site) FC-AI03F 690 FC-AI03Z 651 FC-AI03P 1341 - - Show FC-AI03 Library FC (Link to library) Clone ID FC-AI...nal site URL http://dictycdb.biol.tsukuba.ac.jp/CSM/FC/FC-AI/FC-AI03Q.Seq.d/ Representative seq. ID FC-AI...03P (Link to Original site) Representative DNA sequence >FC-AI03 (FC-AI03Q) /CSM/FC/FC-AI/FC-AI...li*l*ivtlskv*qswyqvfcslmrftcwi*nv fht*ivhwsqhwhql*flqpivaiv*skapitifnlhmaslwif*ivl*sfvpfhiitmk sfkfspfvpqlki

  17. Dicty_cDB: FC-AI12 [Dicty_cDB

    Lifescience Database Archive (English)

    Full Text Available FC (Link to library) FC-AI12 (Link to dictyBase) - - - Contig-U15484-1 FC-AI12Z (Li...nk to Original site) - - FC-AI12Z 614 - - - - Show FC-AI12 Library FC (Link to library) Clone ID FC-AI12 (Li.../dictycdb.biol.tsukuba.ac.jp/CSM/FC/FC-AI/FC-AI12Q.Seq.d/ Representative seq. ID FC-AI...12Z (Link to Original site) Representative DNA sequence >FC-AI12 (FC-AI12Q) /CSM/FC/FC-AI/FC-AI12Q.Seq....EKIVRRI ELLDGITCYRNEKAKDEIVLTGNSLELLSQSCATIQLRSAIKYKDVRKFLDGIYVSERNV LESN*in*riys

  18. Dicty_cDB: FC-AI19 [Dicty_cDB

    Lifescience Database Archive (English)

    Full Text Available FC (Link to library) FC-AI19 (Link to dictyBase) - - - Contig-U15115-1 FC-AI19Z (Li...nk to Original site) - - FC-AI19Z 661 - - - - Show FC-AI19 Library FC (Link to library) Clone ID FC-AI19 (Li.../dictycdb.biol.tsukuba.ac.jp/CSM/FC/FC-AI/FC-AI19Q.Seq.d/ Representative seq. ID FC-AI...19Z (Link to Original site) Representative DNA sequence >FC-AI19 (FC-AI19Q) /CSM/FC/FC-AI/FC-AI19Q.Seq....lmrqswvkkiesi*lvl krrkkkknnkkkkkkkkkkklfn*lvnkkn*ik*kkllcnqkk Frame B: ---*ekaieilsklfsin*kfn**ysiiigkkstkyq

  19. Dicty_cDB: FC-AI14 [Dicty_cDB

    Lifescience Database Archive (English)

    Full Text Available FC (Link to library) FC-AI14 (Link to dictyBase) - - - Contig-U16280-1 FC-AI14Z (Li...nk to Original site) - - FC-AI14Z 671 - - - - Show FC-AI14 Library FC (Link to library) Clone ID FC-AI14 (Li.../dictycdb.biol.tsukuba.ac.jp/CSM/FC/FC-AI/FC-AI14Q.Seq.d/ Representative seq. ID FC-AI...14Z (Link to Original site) Representative DNA sequence >FC-AI14 (FC-AI14Q) /CSM/FC/FC-AI/FC-AI14Q.Seq....nqrllv*lvvlskklqllnsnqsfkfkkvq rmkknsvkntkn*rfvllt*nlkslkrmpksknsptkliifilkly Frame B: ---lkdl*krtphl*stcfhhptlcssrrfclwslnai

  20. Dicty_cDB: FC-AI06 [Dicty_cDB

    Lifescience Database Archive (English)

    Full Text Available FC (Link to library) FC-AI06 (Link to dictyBase) - - - Contig-U16465-1 FC-AI06E (Li...nk to Original site) - - - - - - FC-AI06E 1138 Show FC-AI06 Library FC (Link to library) Clone ID FC-AI06 (L...//dictycdb.biol.tsukuba.ac.jp/CSM/FC/FC-AI/FC-AI06Q.Seq.d/ Representative seq. ID FC-AI...06E (Link to Original site) Representative DNA sequence >FC-AI06 (FC-AI06Q) /CSM/FC/FC-AI/FC-AI06Q.Seq...FGRGIDIERVNVVINYDMAESADTYLHRVGRAGRFGTK GLAISFVPSKEDPVLEQVQSKFVVSIKELVATPDPSTYMSG*kkkkkkkknlfvlksikk k*kkk*in

  1. Dicty_cDB: FC-AI09 [Dicty_cDB

    Lifescience Database Archive (English)

    Full Text Available FC (Link to library) FC-AI09 (Link to dictyBase) - - - Contig-U16149-1 FC-AI09Z (Li...nk to Original site) - - FC-AI09Z 591 - - - - Show FC-AI09 Library FC (Link to library) Clone ID FC-AI09 (Li.../dictycdb.biol.tsukuba.ac.jp/CSM/FC/FC-AI/FC-AI09Q.Seq.d/ Representative seq. ID FC-AI...09Z (Link to Original site) Representative DNA sequence >FC-AI09 (FC-AI09Q) /CSM/FC/FC-AI/FC-AI09Q.Seq....*tkl ik*ilifykiknnkkkkkk Frame B: ---gt*kvpeflailfkrmasrsvlwy*rcltkakkglkapqtltik

  2. Influence of heavy cigarette smoking on heart rate variability and heart rate turbulence parameters

    DEFF Research Database (Denmark)

    Cagirci, Goksel; Cay, Serkan; Karakurt, Ozlem

    2009-01-01

    BACKGROUND: Cigarette smoking increases the risk of cardiovascular events related with several mechanisms. The most suggested mechanism is increased activity of sympathetic nervous system. Heart rate variability (HRV) and heart rate turbulence (HRT) has been shown to be independent and powerful......, 69 subjects and nonsmokers 74 subjects (control group) were enrolled in this study. HRV and HRT analyses [turbulence onset (TO) and turbulence slope (TS)] were assessed from 24-hour Holter recordings. RESULTS: The values of TO were significantly higher in heavy cigarette smokers than control group...... (-1.150 +/- 4.007 vs -2.454 +/- 2.796, P = 0.025, respectively), but values of TS were not statistically different between two groups (10.352 +/- 7.670 vs 9.613 +/- 7.245, P = 0.555, respectively). Also, the number of patients who had abnormal TO was significantly higher in heavy cigarette smokers...

  3. Dicty_cDB: FC-AI15 [Dicty_cDB

    Lifescience Database Archive (English)

    Full Text Available FC (Link to library) FC-AI15 (Link to dictyBase) - G01730 DDB0214993 Contig-U15123-1 FC-AI...15E (Link to Original site) - - - - - - FC-AI15E 856 Show FC-AI15 Library FC (Link to library) Clone ID FC-AI...3-1 Original site URL http://dictycdb.biol.tsukuba.ac.jp/CSM/FC/FC-AI/FC-AI15Q.Se...q.d/ Representative seq. ID FC-AI15E (Link to Original site) Representative DNA sequence >FC-AI15 (FC-AI15Q) /CSM/FC/FC-AI/FC-AI...AAAAAAAATA sequence update 1996.12.24 Translated Amino Acid sequence kt*riyi*KMMIKYITIAILFIASLVKADLQFSLCPTCV

  4. Dicty_cDB: FC-AI24 [Dicty_cDB

    Lifescience Database Archive (English)

    Full Text Available FC (Link to library) FC-AI24 (Link to dictyBase) - - - - FC-AI24Z (Link to Original site) - - FC-AI...24Z 693 - - - - Show FC-AI24 Library FC (Link to library) Clone ID FC-AI24 (Link to dictyBas...e) Atlas ID - NBRP ID - dictyBase ID - Link to Contig - Original site URL http://dictycdb.biol.tsukuba.ac.jp/CSM/FC/FC-AI/FC-AI...24Q.Seq.d/ Representative seq. ID FC-AI24Z (Link to Original s...ite) Representative DNA sequence >FC-AI24 (FC-AI24Q) /CSM/FC/FC-AI/FC-AI24Q.Seq.d/ XXXXXXXXXXAAATTAGAAAACAAA

  5. Role of activatory Fc gamma RI and Fc gamma RIII and inhibitory Fc gamma RII in inflammation and cartilage destruction during experimental antigen-induced arthritis.

    NARCIS (Netherlands)

    Lent, P.L.E.M. van; Nabbe, K.C.A.M.; Blom, A.B.; Holthuysen, A.E.M.; Sloetjes, A.W.; Putte, L.B.A. van de; Verbeek, S.; Berg, W.B. van den

    2001-01-01

    IgG-containing immune complexes, which are found in most RA joints, communicate with hematopoietic cells using three classes of Fc receptors(Fc gamma RI, -II, -III). In a previous study we found that if a chronic T-cell-mediated antigen-induced arthritis (AIA) was elicited in knee joints of FcR

  6. Rapid desensitization of mice with anti-FcγRIIb/FcγRIII mAb safely prevents IgG-mediated anaphylaxis.

    Science.gov (United States)

    Khodoun, Marat V; Kucuk, Zeynep Yesim; Strait, Richard T; Krishnamurthy, Durga; Janek, Kevin; Clay, Corey D; Morris, Suzanne C; Finkelman, Fred D

    2013-12-01

    Stimulatory IgG receptors (FcγRs) on bone marrow-derived cells contribute to the pathogenesis of several autoimmune and inflammatory disorders. Monoclonal antibodies that block FcγRs might suppress these diseases, but they can induce anaphylaxis. We wanted to determine whether a rapid desensitization approach can safely suppress IgG/FcγR-mediated anaphylaxis. Mice were injected with serially increasing doses of 2.4G2, a rat mAb that blocks the inhibitory FcγR, FcγRIIb, and the stimulatory receptor, FcγRIII. Rectal temperature was used to detect the development of anaphylaxis. Passive and active IgG-mediated anaphylaxis were evaluated in mice that had been rapidly desensitized with 2.4G2 or mock-desensitized in mice in which monocyte/macrophages, basophils, or neutrophils had been depleted or desensitized and in mice in which FcγRI, FcγRIII, and/or FcγRIV had been deleted or blocked. Rapid desensitization with 2.4G2 prevented 2.4G2-induced shock and completely suppressed IgG-mediated anaphylaxis. Rapid desensitization of ovalbumin-sensitized mice with 2.4G2 was safer and more effective than rapid desensitization with ovalbumin. 2.4G2 treatment completely blocked FcγRIII and removed most FcγRI and FcγRIV from nucleated peripheral blood cells. Because IgG(2a)-mediated anaphylaxis was partially FcγRI and FcγRIV dependent, the effects of 2.4G2 on FcγRI and FcγRIV were probably crucial for its complete inhibition of IgG(2a)-mediated anaphylaxis. IgG(2a)-mediated anaphylaxis was partially inhibited by depletion or desensitization of monocyte/macrophages, basophils, or neutrophils. IgG-mediated anaphylaxis can be induced by ligation of FcγRI, FcγRIII, or FcγRIV on monocycte/macrophages, basophils, or neutrophils and can be safely suppressed by rapid desensitization with anti-FcγRII/RIII mAb. A similar approach may safely suppress other FcγR-dependent immunopathology. Published by Mosby, Inc.

  7. Dicty_cDB: FC-AI08 [Dicty_cDB

    Lifescience Database Archive (English)

    Full Text Available FC (Link to library) FC-AI08 (Link to dictyBase) - G01729 DDB0233148 Contig-U14939-1 FC-AI...08P (Link to Original site) FC-AI08F 654 FC-AI08Z 563 FC-AI08P 1217 - - Show FC-AI08 Library FC (Link... to library) Clone ID FC-AI08 (Link to dictyBase) Atlas ID - NBRP ID G01729 dictyBase ID DDB0233148 Link to ...Contig Contig-U14939-1 Original site URL http://dictycdb.biol.tsukuba.ac.jp/CSM/FC/FC-AI/FC-AI...08Q.Seq.d/ Representative seq. ID FC-AI08P (Link to Original site) Representative DNA sequence >FC-AI08 (FC-AI

  8. Fc-fusion Proteins in Therapy: An Updated View.

    Science.gov (United States)

    Jafari, Reza; Zolbanin, Naime M; Rafatpanah, Houshang; Majidi, Jafar; Kazemi, Tohid

    2017-01-01

    Fc-fusion proteins are composed of Fc region of IgG antibody (Hinge-CH2-CH3) and a desired linked protein. Fc region of Fc-fusion proteins can bind to neonatal Fc receptor (FcRn) thereby rescuing it from degradation. The first therapeutic Fc-fusion protein was introduced for the treatment of AIDS. The molecular designing is the first stage in production of Fc-fusion proteins. The amino acid residues in the Fc region and linked protein are very important in the bioactivity and affinity of the fusion proteins. Although, therapeutic monoclonal antibodies are the top selling biologics but the application of therapeutic Fc-fusion proteins in clinic is in progress and among these medications Etanercept is the most effective in therapy. At present, eleven Fc-fusion proteins have been approved by FDA. There are novel Fc-fusion proteins which are in pre-clinical and clinical development. In this article, we review the molecular and biological characteristics of Fc-fusion proteins and then further discuss the features of novel therapeutic Fc-fusion proteins. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  9. Dicty_cDB: FC-BR21 [Dicty_cDB

    Lifescience Database Archive (English)

    Full Text Available FC (Link to library) FC-BR21 (Link to dictyBase) - - - Contig-U15384-1 | Contig-U16443-1 FC-BR2...1P (Link to Original site) FC-BR21F 551 FC-BR21Z 122 FC-BR21P 673 - - Show FC-BR21 Library FC (L...ink to library) Clone ID FC-BR21 (Link to dictyBase) Atlas ID - NBRP ID - dictyBase ID - Link to Contig Cont...ig-U15384-1 | Contig-U16443-1 Original site URL http://dictycdb.biol.tsukuba.ac.jp/CSM/FC/FC-BR/FC-BR2...1Q.Seq.d/ Representative seq. ID FC-BR21P (Link to Original site) Representative DNA sequence >FC-BR21 (FC-BR2

  10. Dicty_cDB: FC-AI07 [Dicty_cDB

    Lifescience Database Archive (English)

    Full Text Available FC (Link to library) FC-AI07 (Link to dictyBase) - - - Contig-U15296-1 | Contig-U15756-1 FC-AI...07P (Link to Original site) FC-AI07F 580 FC-AI07Z 723 FC-AI07P 1303 - - Show FC-AI07 Library FC (...Link to library) Clone ID FC-AI07 (Link to dictyBase) Atlas ID - NBRP ID - dictyBase ID - Link to Contig Con...tig-U15296-1 | Contig-U15756-1 Original site URL http://dictycdb.biol.tsukuba.ac.jp/CSM/FC/FC-AI/FC-AI...07Q.Seq.d/ Representative seq. ID FC-AI07P (Link to Original site) Representative DNA sequence >FC-AI07 (FC-AI

  11. Dicty_cDB: FC-AI22 [Dicty_cDB

    Lifescience Database Archive (English)

    Full Text Available FC (Link to library) FC-AI22 (Link to dictyBase) - - - Contig-U15369-1 | Contig-U15732-1 FC-AI...22P (Link to Original site) FC-AI22F 583 FC-AI22Z 683 FC-AI22P 1266 - - Show FC-AI22 Library FC (...Link to library) Clone ID FC-AI22 (Link to dictyBase) Atlas ID - NBRP ID - dictyBase ID - Link to Contig Con...tig-U15369-1 | Contig-U15732-1 Original site URL http://dictycdb.biol.tsukuba.ac.jp/CSM/FC/FC-AI/FC-AI...22Q.Seq.d/ Representative seq. ID FC-AI22P (Link to Original site) Representative DNA sequence >FC-AI22 (FC-AI

  12. Cross-Linking GPVI-Fc by Anti-Fc Antibodies Potentiates Its Inhibition of Atherosclerotic Plaque- and Collagen-Induced Platelet Activation

    Directory of Open Access Journals (Sweden)

    Janina Jamasbi, RPh

    2016-04-01

    Full Text Available To enhance the antithrombotic properties of recombinant glycoprotein VI fragment crystallizable (GPVI-Fc, the authors incubated GPVI-Fc with anti-human Fc antibodies to cross-link the Fc tails of GPVI-Fc. Cross-linking potentiated the inhibition of human plaque- and collagen-induced platelet aggregation by GPVI-Fc under static and flow conditions without increasing bleeding time in vitro. Cross-linking with anti-human-Fc Fab2 was even superior to anti-human-Fc immunoglobulin G (IgG. Advanced optical imaging revealed a continuous sheath-like coverage of collagen fibers by cross-linked GPVI-Fc complexes. Cross-linking of GPVI into oligomeric complexes provides a new, highly effective, and probably safe antithrombotic treatment as it suppresses platelet GPVI-plaque interaction selectively at the site of acute atherothrombosis.

  13. Effect of oxygen treatment on heart rate after abdominal surgery

    DEFF Research Database (Denmark)

    Rosenberg-Adamsen, S; Lie, C; Bernhard, A

    1999-01-01

    BACKGROUND: Cardiac complications are common during the postoperative period and may be associated with hypoxemia and tachycardia. Preliminary studies in high-risk patients after operation have shown a possible beneficial effect of oxygen therapy on arterial oxygen saturation and heart rate....... METHODS: The authors studied the effect of oxygen therapy on arterial oxygen saturation and heart rate in 100 consecutive unselected patients randomly and double blindly allocated to receive air or oxygen therapy between the first and fourth day after major abdominal surgery. RESULTS: The median arterial...... oxygen saturation rate increased significantly from 96% to 99% (P heart rate decreased significantly from 85 beats/min to 81 beats/min (P heart rate occurred...

  14. The neonatal Fc receptor (FcRn) binds independently to both sites of the IgG homodimer with identical affinity.

    Science.gov (United States)

    Abdiche, Yasmina Noubia; Yeung, Yik Andy; Chaparro-Riggers, Javier; Barman, Ishita; Strop, Pavel; Chin, Sherman Michael; Pham, Amber; Bolton, Gary; McDonough, Dan; Lindquist, Kevin; Pons, Jaume; Rajpal, Arvind

    2015-01-01

    The neonatal Fc receptor (FcRn) is expressed by cells of epithelial, endothelial and myeloid lineages and performs multiple roles in adaptive immunity. Characterizing the FcRn/IgG interaction is fundamental to designing therapeutic antibodies because IgGs with moderately increased binding affinities for FcRn exhibit superior serum half-lives and efficacy. It has been hypothesized that 2 FcRn molecules bind an IgG homodimer with disparate affinities, yet their affinity constants are inconsistent across the literature. Using surface plasmon resonance biosensor assays that eliminated confounding experimental artifacts, we present data supporting an alternate hypothesis: 2 FcRn molecules saturate an IgG homodimer with identical affinities at independent sites, consistent with the symmetrical arrangement of the FcRn/Fc complex observed in the crystal structure published by Burmeister et al. in 1994. We find that human FcRn binds human IgG1 with an equilibrium dissociation constant (KD) of 760 ± 60 nM (N = 14) at 25°C and pH 5.8, and shows less than 25% variation across the other human subtypes. Human IgG1 binds cynomolgus monkey FcRn with a 2-fold higher affinity than human FcRn, and binds both mouse and rat FcRn with a 10-fold higher affinity than human FcRn. FcRn/IgG interactions from multiple species show less than a 2-fold weaker affinity at 37°C than at 25°C and appear independent of an IgG's variable region. Our in vivo data in mouse and rat models demonstrate that both affinity and avidity influence an IgG's serum half-life, which should be considered when choosing animals, especially transgenic systems, as surrogates.

  15. Activatory and Inhibitory Fcγ Receptors Augment Rituximab-mediated Internalization of CD20 Independent of Signaling via the Cytoplasmic Domain*

    Science.gov (United States)

    Vaughan, Andrew T.; Chan, Claude H. T.; Klein, Christian; Glennie, Martin J.; Beers, Stephen A.; Cragg, Mark S.

    2015-01-01

    Type I anti-CD20 mAb such as rituximab and ofatumumab engage with the inhibitory FcγR, FcγRIIb on the surface of B cells, resulting in immunoreceptor tyrosine-based inhibitory motif (ITIM) phosphorylation. Internalization of the CD20·mAb·FcγRIIb complex follows, the rate of which correlates with FcγRIIb expression. In contrast, although type II anti-CD20 mAb such as tositumomab and obinutuzumab also interact with and activate FcγRIIb, this interaction fails to augment the rate of CD20·mAb internalization, raising the question of whether ITIM phosphorylation plays any role in this process. We have assessed the molecular requirements for the internalization process and demonstrate that in contrast to internalization of IgG immune complexes, FcγRIIb-augmented internalization of rituximab-ligated CD20 occurs independently of the FcγRIIb ITIM, indicating that signaling downstream of FcγRIIb is not required. In transfected cells, activatory FcγRI, FcγRIIa, and FcγRIIIa augmented internalization of rituximab-ligated CD20 in a similar manner. However, FcγRIIa mediated a slower rate of internalization than cells expressing equivalent levels of the highly homologous FcγRIIb. The difference was maintained in cells expressing FcγRIIa and FcγRIIb lacking cytoplasmic domains and in which the transmembrane domains had been exchanged. This difference may be due to increased degradation of FcγRIIa, which traffics to lysosomes independently of rituximab. We conclude that the cytoplasmic domain of FcγR is not required for promoting internalization of rituximab-ligated CD20. Instead, we propose that FcγR provides a structural role in augmenting endocytosis that differs from that employed during the endocytosis of immune complexes. PMID:25568316

  16. Blood Pressure vs. Heart Rate

    Science.gov (United States)

    ... Peripheral Artery Disease Venous Thromboembolism Aortic Aneurysm More Blood Pressure vs. Heart Rate (Pulse) Updated:Nov 13,2017 ... This content was last reviewed October 2016. High Blood Pressure • Home • Get the Facts About HBP Introduction What ...

  17. CHRONIC HEART FAILURE AND IRON-DEFICIENT ANEMIA

    Directory of Open Access Journals (Sweden)

    M. V. Melnik

    2015-12-01

    Full Text Available 62 chronic heart failure (CHF patients with iron-deficient anemia (IDA were studied. Standard CHF therapy (angiotensin converting enzyme inhibitors, β-blockers, diuretics, cardiac glycosides was accompanied with the correction of iron deficiency by intravenous injection of Venofer and subsequent Ferro-Folgamma prescription (average daily dose of iron 137,75±5mg. After treatment serum iron level increased by 95,5% and hemoglobin level – by 9,8%. Left ventricular ejection fraction increased by 32,2% and physical activity tolerance – by 47,6%. Before treatment 32 CHF patients with IDA (51,6% had III functional class (FC of CHF according to NYHA and 16 patients (25,8% – IV FC. After treatment I FC was observed in 18 CHF patients (29%, II FC – in 26 patients and only 18 patients demonstrated III FC of CHF.

  18. CHRONIC HEART FAILURE AND IRON-DEFICIENT ANEMIA

    Directory of Open Access Journals (Sweden)

    M. V. Melnik

    2007-01-01

    Full Text Available 62 chronic heart failure (CHF patients with iron-deficient anemia (IDA were studied. Standard CHF therapy (angiotensin converting enzyme inhibitors, β-blockers, diuretics, cardiac glycosides was accompanied with the correction of iron deficiency by intravenous injection of Venofer and subsequent Ferro-Folgamma prescription (average daily dose of iron 137,75±5mg. After treatment serum iron level increased by 95,5% and hemoglobin level – by 9,8%. Left ventricular ejection fraction increased by 32,2% and physical activity tolerance – by 47,6%. Before treatment 32 CHF patients with IDA (51,6% had III functional class (FC of CHF according to NYHA and 16 patients (25,8% – IV FC. After treatment I FC was observed in 18 CHF patients (29%, II FC – in 26 patients and only 18 patients demonstrated III FC of CHF.

  19. Heart rate and heart rate variability modification in chronic insomnia patients.

    Science.gov (United States)

    Farina, Benedetto; Dittoni, Serena; Colicchio, Salvatore; Testani, Elisa; Losurdo, Anna; Gnoni, Valentina; Di Blasi, Chiara; Brunetti, Riccardo; Contardi, Anna; Mazza, Salvatore; Della Marca, Giacomo

    2014-01-01

    Chronic insomnia is highly prevalent in the general population, provoking personal distress and increased risk for psychiatric and medical disorders. Autonomic hyper-arousal could be a pathogenic mechanism of chronic primary insomnia. The aim of this study was to investigate autonomic activity in patients with chronic primary insomnia by means of heart rate variability (HRV) analysis. Eighty-five consecutive patients affected by chronic primary insomnia were enrolled (38 men and 47 women; mean age: 53.2 ± 13.6). Patients were compared with a control group composed of 55 healthy participants matched for age and gender (23 men and 32 women; mean age: 54.2 ± 13.9). Patients underwent an insomnia study protocol that included subjective sleep evaluation, psychometric measures, and home-based polysomnography with evaluation of HRV in wake before sleep, in all sleep stages, and in wake after final awakening. Patients showed modifications of heart rate and HRV parameters, consistent with increased sympathetic activity, while awake before sleep and during Stage-2 non-REM sleep. No significant differences between insomniacs and controls could be detected during slow-wave sleep, REM sleep, and post-sleep wake. These results are consistent with the hypothesis that autonomic hyper-arousal is a major pathogenic mechanism in primary insomnia, and confirm that this condition is associated with an increased cardiovascular risk.

  20. Exaggerated heart rate oscillations during two meditation techniques.

    Science.gov (United States)

    Peng, C K; Mietus, J E; Liu, Y; Khalsa, G; Douglas, P S; Benson, H; Goldberger, A L

    1999-07-31

    We report extremely prominent heart rate oscillations associated with slow breathing during specific traditional forms of Chinese Chi and Kundalini Yoga meditation techniques in healthy young adults. We applied both spectral analysis and a novel analytic technique based on the Hilbert transform to quantify these heart rate dynamics. The amplitude of these oscillations during meditation was significantly greater than in the pre-meditation control state and also in three non-meditation control groups: i) elite athletes during sleep, ii) healthy young adults during metronomic breathing, and iii) healthy young adults during spontaneous nocturnal breathing. This finding, along with the marked variability of the beat-to-beat heart rate dynamics during such profound meditative states, challenges the notion of meditation as only an autonomically quiescent state.

  1. Association of heart rate profile during exercise with the severity of coronary artery disease.

    Science.gov (United States)

    Cay, Serkan; Ozturk, Sezgin; Biyikoglu, Funda; Yildiz, Abdulkadir; Cimen, Tolga; Uygur, Belma; Tuna, Funda

    2009-05-01

    Coronary artery disease is the leading cause of morbidity and mortality around the world. Autonomic nervous system abnormalities are associated with coronary artery disease and its complications. Exercise stress tests are routinely used for the detection of the presence of coronary artery disease. In this study, we observed the association between heart rate profile during exercise and the severity of coronary artery disease. One hundred and sixty patients with abnormal exercise treadmill test (> or =1 mm horizontal or downsloping ST-segment depression; 119 men, 41 women; mean age = 57 +/- 9 years) were included in the study. Use of any drug affecting heart rate was not permitted. Resting heart rate before exercise, maximum heart rate during exercise, and resting heart rate after exercise (5 min later) were measured and two parameters were calculated: heart rate increment (maximum heart rate - resting heart rate before exercise) and heart rate decrement (maximum heart rate - resting heart rate after exercise). All patients underwent selective coronary angiography and subclassified into two groups according to stenotic lesion severity. Group 1 had at least 50% of stenotic lesion and group 2 had less than 50%. Patients in the first group had increased resting heart rate, decreased maximum heart rate, decreased heart rate increment, and decreased heart rate decrement compared with second group. All patients were classified into tertiles of resting heart rate, heart rate increment, and heart rate decrement level to evaluate whether these parameters were associated with severity of coronary artery stenosis in the study. The multiple-adjusted odds ratio of the risk of severe coronary atherosclerosis was 21.888 (95% confidence interval 6.983-68.606) for the highest tertile of resting heart rate level compared with the lowest tertile. In addition, the multiple-adjusted odds ratio of the risk of severe coronary atherosclerosis was 20.987 (95% confidence interval 6

  2. Discovery of novel heart rate-associated loci using the Exome Chip

    DEFF Research Database (Denmark)

    van den Berg, Marten E; Warren, Helen R; Cabrera, Claudia P

    2017-01-01

    Resting heart rate is a heritable trait, and an increase in heart rate is associated with increased mortality risk. Genome-wide association study analyses have found loci associated with resting heart rate, at the time of our study these loci explained 0.9% of the variation. This study aims to di......) and fetal muscle samples by including our novel variants.Our findings advance the knowledge of the genetic architecture of heart rate, and indicate new candidate genes for follow-up functional studies....

  3. A randomised, simulated study assessing auscultation of heart rate at birth

    NARCIS (Netherlands)

    Voogdt, Kevin G. J. A.; Morrison, Allison C.; Wood, Fiona E.; van Elburg, Ruurd M.; Wyllie, Jonathan P.

    2010-01-01

    Heart rate is a primary clinical indicator directing newborn resuscitation. The time taken to assess the heart rate by auscultation in relation to accuracy during newborn resuscitation is not known. To assess both the accuracy and time taken to assess heart rate by stethoscope in simulated

  4. Assessment of post-laparotomy pain in laboratory mice by telemetric recording of heart rate and heart rate variability

    Science.gov (United States)

    Arras, Margarete; Rettich, Andreas; Cinelli, Paolo; Kasermann, Hans P; Burki, Kurt

    2007-01-01

    Background Pain of mild to moderate grade is difficult to detect in laboratory mice because mice are prey animals that attempt to elude predators or man by hiding signs of weakness, injury or pain. In this study, we investigated the use of telemetry to identify indicators of mild-to-moderate post-laparotomy pain. Results Adult mice were subjected to laparotomy, either combined with pain treatment (carprofen or flunixin, 5 mg/kg s/c bid, for 1 day) or without pain relief. Controls received anesthesia and analgesics or vehicle only. Telemetrically measured locomotor activity was undisturbed in all animals, thus confirming that any pain experienced was of the intended mild level. No symptoms of pain were registered in any of the groups by scoring the animals' outer appearance or spontaneous and provoked behavior. In contrast, the group receiving no analgesic treatment after laparotomy demonstrated significant changes in telemetry electrocardiogram recordings: increased heart rate and decreased heart rate variability parameters pointed to sympathetic activation and pain lasting for 24 hours. In addition, core body temperature was elevated. Body weight and food intake were reduced for 3 and 2 days, respectively. Moreover, unstructured cage territory and destroyed nests appeared for 1–2 days in an increased number of animals in this group only. In controls these parameters were not affected. Conclusion In conclusion, real-time telemetric recordings of heart rate and heart rate variability were indicative of mild-to-moderate post-laparotomy pain and could define its duration in our mouse model. This level of pain cannot easily be detected by direct observation. PMID:17683523

  5. Effects of Malaria on Blood Pressure, Heart Rate, Electrocardiogram ...

    African Journals Online (AJOL)

    The effect of malaria on blood pressure, heart rate, electrocardiogram and the cardiovascular responses to postural change were studied in malaria patients. Blood pressure was measured by the sphygmomanometric-auscultatory method. Standard ECG machine was used to record the electrocardiogram. Heart rate was ...

  6. Probability of detection of clinical seizures using heart rate changes.

    Science.gov (United States)

    Osorio, Ivan; Manly, B F J

    2015-08-01

    Heart rate-based seizure detection is a viable complement or alternative to ECoG/EEG. This study investigates the role of various biological factors on the probability of clinical seizure detection using heart rate. Regression models were applied to 266 clinical seizures recorded from 72 subjects to investigate if factors such as age, gender, years with epilepsy, etiology, seizure site origin, seizure class, and data collection centers, among others, shape the probability of EKG-based seizure detection. Clinical seizure detection probability based on heart rate changes, is significantly (pprobability of detecting clinical seizures (>0.8 in the majority of subjects) using heart rate is highest for complex partial seizures, increases with a patient's years with epilepsy, is lower for females than for males and is unrelated to the side of hemisphere origin. Clinical seizure detection probability using heart rate is multi-factorially dependent and sufficiently high (>0.8) in most cases to be clinically useful. Knowledge of the role that these factors play in shaping said probability will enhance its applicability and usefulness. Heart rate is a reliable and practical signal for extra-cerebral detection of clinical seizures originating from or spreading to central autonomic network structures. Copyright © 2015 British Epilepsy Association. Published by Elsevier Ltd. All rights reserved.

  7. "Heart rate-dependent" electrocardiographic diagnosis of left ventricular hypertrophy.

    Science.gov (United States)

    Madias, John E

    2013-05-01

    A case is presented revealing the common phenomenon of heart rate-dependent diagnosis of electrocardiographic (ECG) diagnosis of left ventricular hypertrophy (LVH), which consists of satisfaction of LVH criteria only at faster rates whereas ECGs with a slow heart rate do not satisfy such criteria. The mechanism of the phenomenon has been attributed to the tachycardia-mediated underfilling of the left ventricle bringing the electrical "centroid" of the heart closer to the recording electrodes, which results in augmentation of the amplitude of QRS complexes, particularly in leads V2-V4. ©2012, The Author. Journal compilation ©2012 Wiley Periodicals, Inc.

  8. Bluetooth Heart Rate Monitors For Spaceflight

    Science.gov (United States)

    Buxton, R. E.; West, M. R.; Kalogera, K. L.; Hanson, A. M.

    2016-01-01

    Heart rate monitoring is required for crewmembers during exercise aboard the International Space Station (ISS) and will be for future exploration missions. The cardiovascular system must be sufficiently stressed throughout a mission to maintain the ability to perform nominal and contingency/emergency tasks. High quality heart rate data are required to accurately determine the intensity of exercise performed by the crewmembers and show maintenance of VO2max. The quality of the data collected on ISS is subject to multiple limitations and is insufficient to meet current requirements. PURPOSE: To evaluate the performance of commercially available Bluetooth heart rate monitors (BT_HRM) and their ability to provide high quality heart rate data to monitor crew health aboard the ISS and during future exploration missions. METHODS: Nineteen subjects completed 30 data collection sessions of various intensities on the treadmill and/or cycle. Subjects wore several BT_HRM technologies for each testing session. One electrode-based chest strap (CS) was worn, while one or more optical sensors (OS) were worn. Subjects were instrumented with a 12-lead ECG to compare the heart rate data from the Bluetooth sensors. Each BT_HRM data set was time matched to the ECG data and a +/-5bpm threshold was applied to the difference between the 2 data sets. Percent error was calculated based on the number of data points outside the threshold and the total number of data points. RESULTS: The electrode-based chest straps performed better than the optical sensors. The best performing CS was CS1 (1.6% error), followed by CS4 (3.3% error), CS3 (6.4% error), and CS2 (9.2% error). The OS resulted in 10.4% error for OS1 and 14.9% error for OS2. CONCLUSIONS: The highest quality data came from CS1, but unfortunately it has been discontinued by the manufacturer. The optical sensors have not been ruled out for use, but more investigation is needed to determine how to obtain the best quality data. CS2 will be

  9. Activatory and inhibitory Fcγ receptors augment rituximab-mediated internalization of CD20 independent of signaling via the cytoplasmic domain.

    Science.gov (United States)

    Vaughan, Andrew T; Chan, Claude H T; Klein, Christian; Glennie, Martin J; Beers, Stephen A; Cragg, Mark S

    2015-02-27

    Type I anti-CD20 mAb such as rituximab and ofatumumab engage with the inhibitory FcγR, FcγRIIb on the surface of B cells, resulting in immunoreceptor tyrosine-based inhibitory motif (ITIM) phosphorylation. Internalization of the CD20·mAb·FcγRIIb complex follows, the rate of which correlates with FcγRIIb expression. In contrast, although type II anti-CD20 mAb such as tositumomab and obinutuzumab also interact with and activate FcγRIIb, this interaction fails to augment the rate of CD20·mAb internalization, raising the question of whether ITIM phosphorylation plays any role in this process. We have assessed the molecular requirements for the internalization process and demonstrate that in contrast to internalization of IgG immune complexes, FcγRIIb-augmented internalization of rituximab-ligated CD20 occurs independently of the FcγRIIb ITIM, indicating that signaling downstream of FcγRIIb is not required. In transfected cells, activatory FcγRI, FcγRIIa, and FcγRIIIa augmented internalization of rituximab-ligated CD20 in a similar manner. However, FcγRIIa mediated a slower rate of internalization than cells expressing equivalent levels of the highly homologous FcγRIIb. The difference was maintained in cells expressing FcγRIIa and FcγRIIb lacking cytoplasmic domains and in which the transmembrane domains had been exchanged. This difference may be due to increased degradation of FcγRIIa, which traffics to lysosomes independently of rituximab. We conclude that the cytoplasmic domain of FcγR is not required for promoting internalization of rituximab-ligated CD20. Instead, we propose that FcγR provides a structural role in augmenting endocytosis that differs from that employed during the endocytosis of immune complexes. © 2015 by The American Society for Biochemistry and Molecular Biology, Inc.

  10. Intrapartum fetal heart rate profiles with and without fetal asphyxia.

    Science.gov (United States)

    Low, J A; Pancham, S R; Worthington, D N

    1977-04-01

    Fetal heart rate profiles for periods up to 12 hours prior to delivery have been reviewed in 515 patients with a fetus at risk. Mechanisms other than fetal asphyxia will cause fetal heart rate decelerations, and fetal asphyxia may in some instances develop in the absence of total or late decelerations. However, an increasing incidence of total decelerations and late decelerations and particularly a marked pattern of total decelerations and late decelerations are of value in the prediction of fetal asphyxia. Fetal heart rate deceleration patterns can predict the probability of fetal asphyxia at the time of initial intervention, while a progression of fetal heart rate deceleration patterns in the individual fetus can be of assistance in the subsequent scheduling of serial acid-base assessments during labor.

  11. Effects of heart rate on myocardial thallium-201 uptake and clearance

    International Nuclear Information System (INIS)

    Nordrehaug, J.E.; Danielsen, R.; Vik-Mo, H.

    1989-01-01

    The effects of heart rate on the myocardial uptake and clearance of 201 Tl were studied prospectively in seven healthy men, mean age 43 +/- 7 (s.d.) yr. Initial and delayed (3 hr) thallium images were obtained in three views after three bicycle exercise tests: to maximal, 80% and 60% of predicted maximal heart rate. The mean of three views initial myocardial 201 Tl uptake was higher at maximal than at both 80% and 60% of predicted maximal heart rate, being 81% (p less than 0.01) and 60% (p less than 0.01) of maximal activity, respectively. The myocardial activity in the delayed images was identical. There was a linear relationship between heart rate and the initial myocardial activity, r = 0.86 (p less than 0.001). The mean (range) 201 Tl clearance was 58% (51-65), 47% (34-56), and 34% (22-49) (all differences p less than 0.01), respectively. Concordance among the three individual views in estimating clearance was best for the highest exercise level. There was a linear relationship between heart rate and clearance, r = 0.80 (p less than 0.001). Clearance was altered by only 1.67 x 10%/heart bpm (0.024 hr/heart beat). Clearance in the liver, spleen and lungs increased at submaximal exercise levels. Thus, a linear relationship between heart rate and clearance is the result of changes in the initial exercise myocardial 201 Tl activity. Submaximal exercise may reduce reproducibility of clearance estimation, and the change of myocardial clearance with heart rate seems less than previously suggested

  12. Biosynthesis of the Essential Fatty Acid Oxidation Cofactor Carnitine Is Stimulated in Heart and Liver after a Single Bout of Exercise in Mice

    Directory of Open Access Journals (Sweden)

    Tom L. Broderick

    2018-01-01

    Full Text Available We determined whether one single bout of exercise stimulates carnitine biosynthesis and carnitine uptake in liver and heart. Free carnitine (FC in plasma was assayed using acetyltransferase and [14C]acetyl-CoA in Swiss Webster mice after 1 hour of moderate-intensity treadmill running or 4 hours and 8 hours into recovery. Liver and heart were removed under the same conditions for measurement of carnitine biosynthesis enzymes (liver butyrobetaine hydroxylase, γ-BBH; heart trimethyllysine dioxygenase, TMLD, organic cation transporter-2 (OCTN2, carnitine transporter, and liver peroxisome proliferator-activated receptor-alpha (PPARα, transcription factor for γ-BBH and OCTN2 synthesis. In exercised mice, FC levels in plasma decreased while heart and liver OCTN2 protein expressed increased, reflecting active uptake of FC. During recovery, the rise in FC to control levels was associated with increased liver γ-BBH expression. Protein expression of PPARα was stimulated in liver after exercise and during recovery. Interestingly, heart TMLD protein was also detected after exercise. Acute exercise stimulates carnitine uptake in liver and heart. The rapid return of FC levels in plasma after exercise indicates carnitine biosynthesis by liver is stimulated to establish carnitine homeostasis. Our results suggest that exercise may benefit patients with carnitine deficiency syndromes.

  13. Relative influence of age, resting heart rate and sedentary life style in short-term analysis of heart rate variability

    OpenAIRE

    E.R. Migliaro; P. Contreras; S. Bech; A. Etxagibel; M. Castro; R. Ricca; K. Vicente

    2001-01-01

    In order to assess the relative influence of age, resting heart rate (HR) and sedentary life style, heart rate variability (HRV) was studied in two different groups. The young group (YG) consisted of 9 sedentary subjects aged 15 to 20 years (YG-S) and of 9 nonsedentary volunteers (YG-NS) also aged 15 to 20. The elderly sedentary group (ESG) consisted of 16 sedentary subjects aged 39 to 82 years. HRV was assessed using a short-term procedure (5 min). R-R variability was calculated in the time-...

  14. Human FcγRIIA induces anaphylactic and allergic reactions.

    Science.gov (United States)

    Jönsson, Friederike; Mancardi, David A; Zhao, Wei; Kita, Yoshihiro; Iannascoli, Bruno; Khun, Huot; van Rooijen, Nico; Shimizu, Takao; Schwartz, Lawrence B; Daëron, Marc; Bruhns, Pierre

    2012-03-15

    IgE and IgE receptors (FcεRI) are well-known inducers of allergy. We recently found in mice that active systemic anaphylaxis depends on IgG and IgG receptors (FcγRIIIA and FcγRIV) expressed by neutrophils, rather than on IgE and FcεRI expressed by mast cells and basophils. In humans, neutrophils, mast cells, basophils, and eosinophils do not express FcγRIIIA or FcγRIV, but FcγRIIA. We therefore investigated the possible role of FcγRIIA in allergy by generating novel FcγRIIA-transgenic mice, in which various models of allergic reactions induced by IgG could be studied. In mice, FcγRIIA was sufficient to trigger active and passive anaphylaxis, and airway inflammation in vivo. Blocking FcγRIIA in vivo abolished these reactions. We identified mast cells to be responsible for FcγRIIA-dependent passive cutaneous anaphylaxis, and monocytes/macrophages and neutrophils to be responsible for FcγRIIA-dependent passive systemic anaphylaxis. Supporting these findings, human mast cells, monocytes and neutrophils produced anaphylactogenic mediators after FcγRIIA engagement. IgG and FcγRIIA may therefore contribute to allergic and anaphylactic reactions in humans.

  15. Assessment of post-laparotomy pain in laboratory mice by telemetric recording of heart rate and heart rate variability

    Directory of Open Access Journals (Sweden)

    Kasermann Hans P

    2007-08-01

    Full Text Available Abstract Background Pain of mild to moderate grade is difficult to detect in laboratory mice because mice are prey animals that attempt to elude predators or man by hiding signs of weakness, injury or pain. In this study, we investigated the use of telemetry to identify indicators of mild-to-moderate post-laparotomy pain. Results Adult mice were subjected to laparotomy, either combined with pain treatment (carprofen or flunixin, 5 mg/kg s/c bid, for 1 day or without pain relief. Controls received anesthesia and analgesics or vehicle only. Telemetrically measured locomotor activity was undisturbed in all animals, thus confirming that any pain experienced was of the intended mild level. No symptoms of pain were registered in any of the groups by scoring the animals' outer appearance or spontaneous and provoked behavior. In contrast, the group receiving no analgesic treatment after laparotomy demonstrated significant changes in telemetry electrocardiogram recordings: increased heart rate and decreased heart rate variability parameters pointed to sympathetic activation and pain lasting for 24 hours. In addition, core body temperature was elevated. Body weight and food intake were reduced for 3 and 2 days, respectively. Moreover, unstructured cage territory and destroyed nests appeared for 1–2 days in an increased number of animals in this group only. In controls these parameters were not affected. Conclusion In conclusion, real-time telemetric recordings of heart rate and heart rate variability were indicative of mild-to-moderate post-laparotomy pain and could define its duration in our mouse model. This level of pain cannot easily be detected by direct observation.

  16. Modulations of Heart Rate, ECG, and Cardio-Respiratory Coupling Observed in Polysomnography

    Directory of Open Access Journals (Sweden)

    Thomas Penzel

    2016-10-01

    Full Text Available The cardiac component of cardio-respiratory polysomnography is covered by ECG and heart rate recordings. However their evaluation is often underrepresented in summarizing reports. As complements to EEG, EOG, and EMG, these signals provide diagnostic information for autonomic nervous activity during sleep. This review presents major methodological developments in sleep research regarding heart rate, ECG and cardio-respiratory couplings in a chronological (historical sequence. It presents physiological and pathophysiological insights related to sleep medicine obtained by new technical developments. Recorded nocturnal ECG facilitates conventional heart rate variability analysis, studies of cyclical variations of heart rate, and analysis of ECG waveform. In healthy adults, the autonomous nervous system is regulated in totally different ways during wakefulness, slow-wave sleep, and REM sleep. Analysis of beat-to-beat heart-rate variations with statistical methods enables us to estimate sleep stages based on the differences in autonomic nervous system regulation. Furthermore, up to some degree, it is possible to track transitions from wakefulness to sleep by analysis of heart-rate variations. ECG and heart rate analysis allow assessment of selected sleep disorders as well. Sleep disordered breathing can be detected reliably by studying cyclical variation of heart rate combined with respiration-modulated changes in ECG morphology (amplitude of R wave and T wave.

  17. Modulations of Heart Rate, ECG, and Cardio-Respiratory Coupling Observed in Polysomnography.

    Science.gov (United States)

    Penzel, Thomas; Kantelhardt, Jan W; Bartsch, Ronny P; Riedl, Maik; Kraemer, Jan F; Wessel, Niels; Garcia, Carmen; Glos, Martin; Fietze, Ingo; Schöbel, Christoph

    2016-01-01

    The cardiac component of cardio-respiratory polysomnography is covered by ECG and heart rate recordings. However, their evaluation is often underrepresented in summarizing reports. As complements to EEG, EOG, and EMG, these signals provide diagnostic information for autonomic nervous activity during sleep. This review presents major methodological developments in sleep research regarding heart rate, ECG, and cardio-respiratory couplings in a chronological (historical) sequence. It presents physiological and pathophysiological insights related to sleep medicine obtained by new technical developments. Recorded nocturnal ECG facilitates conventional heart rate variability (HRV) analysis, studies of cyclical variations of heart rate, and analysis of ECG waveform. In healthy adults, the autonomous nervous system is regulated in totally different ways during wakefulness, slow-wave sleep, and REM sleep. Analysis of beat-to-beat heart-rate variations with statistical methods enables us to estimate sleep stages based on the differences in autonomic nervous system regulation. Furthermore, up to some degree, it is possible to track transitions from wakefulness to sleep by analysis of heart-rate variations. ECG and heart rate analysis allow assessment of selected sleep disorders as well. Sleep disordered breathing can be detected reliably by studying cyclical variation of heart rate combined with respiration-modulated changes in ECG morphology (amplitude of R wave and T wave).

  18. Using Complexity Metrics With R-R Intervals and BPM Heart Rate Measures

    DEFF Research Database (Denmark)

    Wallot, Sebastian; Fusaroli, Riccardo; Tylén, Kristian

    2013-01-01

    Lately, growing attention in the health sciences has been paid to the dynamics of heart rate as indicator of impending failures and for prognoses. Likewise, in social and cognitive sciences, heart rate is increasingly employed as a measure of arousal, emotional engagement and as a marker of inter......Lately, growing attention in the health sciences has been paid to the dynamics of heart rate as indicator of impending failures and for prognoses. Likewise, in social and cognitive sciences, heart rate is increasingly employed as a measure of arousal, emotional engagement and as a marker...... of interpersonal coordination. However, there is no consensus about which measurements and analytical tools are most appropriate in mapping the temporal dynamics of heart rate and quite different metrics are reported in the literature. As complexity metrics of heart rate variability depend critically...

  19. Heart rate variability in newborns.

    Science.gov (United States)

    Javorka, K; Lehotska, Z; Kozar, M; Uhrikova, Z; Kolarovszki, B; Javorka, M; Zibolen, M

    2017-09-22

    Heart rate (HR) and heart rate variability (HRV) in newborns is influenced by genetic determinants, gestational and postnatal age, and other variables. Premature infants have a reduced HRV. In neonatal HRV evaluated by spectral analysis, a dominant activity can be found in low frequency (LF) band (combined parasympathetic and sympathetic component). During the first postnatal days the activity in the high frequency (HF) band (parasympathetic component) rises, together with an increase in LF band and total HRV. Hypotrophy in newborn can cause less mature autonomic cardiac control with a higher contribution of sympathetic activity to HRV as demonstrated by sequence plot analysis. During quiet sleep (QS) in newborns HF oscillations increase - a phenomenon less expressed or missing in premature infants. In active sleep (AS), HRV is enhanced in contrast to reduced activity in HF band due to the rise of spectral activity in LF band. Comparison of the HR and HRV in newborns born by physiological vaginal delivery, without (VD) and with epidural anesthesia (EDA) and via sectio cesarea (SC) showed no significant differences in HR and in HRV time domain parameters. Analysis in the frequency domain revealed, that the lowest sympathetic activity in chronotropic cardiac chronotropic regulation is in the VD group. Different neonatal pathological states can be associated with a reduction of HRV and an improvement in the health conditions is followed by changes in HRV what can be use as a possible prognostic marker. Examination of heart rate variability in neonatology can provide information on the maturity of the cardiac chronotropic regulation in early postnatal life, on postnatal adaptation and in pathological conditions about the potential dysregulation of cardiac function in newborns, especially in preterm infants.

  20. Quantification of fetal heart rate regularity using symbolic dynamics

    Science.gov (United States)

    van Leeuwen, P.; Cysarz, D.; Lange, S.; Geue, D.; Groenemeyer, D.

    2007-03-01

    Fetal heart rate complexity was examined on the basis of RR interval time series obtained in the second and third trimester of pregnancy. In each fetal RR interval time series, short term beat-to-beat heart rate changes were coded in 8bit binary sequences. Redundancies of the 28 different binary patterns were reduced by two different procedures. The complexity of these sequences was quantified using the approximate entropy (ApEn), resulting in discrete ApEn values which were used for classifying the sequences into 17 pattern sets. Also, the sequences were grouped into 20 pattern classes with respect to identity after rotation or inversion of the binary value. There was a specific, nonuniform distribution of the sequences in the pattern sets and this differed from the distribution found in surrogate data. In the course of gestation, the number of sequences increased in seven pattern sets, decreased in four and remained unchanged in six. Sequences that occurred less often over time, both regular and irregular, were characterized by patterns reflecting frequent beat-to-beat reversals in heart rate. They were also predominant in the surrogate data, suggesting that these patterns are associated with stochastic heart beat trains. Sequences that occurred more frequently over time were relatively rare in the surrogate data. Some of these sequences had a high degree of regularity and corresponded to prolonged heart rate accelerations or decelerations which may be associated with directed fetal activity or movement or baroreflex activity. Application of the pattern classes revealed that those sequences with a high degree of irregularity correspond to heart rate patterns resulting from complex physiological activity such as fetal breathing movements. The results suggest that the development of the autonomic nervous system and the emergence of fetal behavioral states lead to increases in not only irregular but also regular heart rate patterns. Using symbolic dynamics to

  1. Diminution of Heart Rate Variability in Bipolar Depression

    Directory of Open Access Journals (Sweden)

    Brandon Hage

    2017-12-01

    Full Text Available Autonomic nervous system (ANS dysregulation in depression is associated with symptoms associated with the ANS. The beat-to-beat pattern of heart rate defined as heart rate variability (HRV provides a noninvasive portal to ANS function and has been proposed to represent a means of quantifying resting vagal tone. We quantified HRV in bipolar depressed (BDD patients as a measure of ANS dysregulation seeking to establish HRV as a potential diagnostic and prognostic biomarker for treatment outcome. Forty-seven BDD patients were enrolled. They were randomized to receive either escitalopram–celecoxib or escitalopram-placebo over 8 weeks in a double-blind study design. Thirty-five patients completed the HRV studies. Thirty-six healthy subjects served as controls. HRV was assessed at pretreatment and end of study and compared with that of controls. HRV was quantified and corrected for artifacts using an algorithm that incorporates time and frequency domains to address non-stationarity of the beat-to-beat heart rate pattern. Baseline high frequency-HRV (i.e., respiratory sinus arrhythmia was lower in BDD patients than controls, although the difference did not reach significance. Baseline low-frequency HRV was significantly lower in BDD patients (ln4.20 than controls (ln = 5.50 (p < 0.01. Baseline heart period was significantly shorter (i.e., faster heart rate in BDD patients than controls. No significant change in HRV parameters were detected over the course of the study with either treatment. These findings suggest that components of HRV may be diminished in BDD patients.

  2. Modeling baroreflex regulation of heart rate during orthostatic stress

    DEFF Research Database (Denmark)

    Olufsen, Mette; Tran, Hien T.; Ottesen, Johnny T.

    2006-01-01

    . The model uses blood pressure measured in the finger as an input to model heart rate dynamics in response to changes in baroreceptor nerve firing rate, sympathetic and parasympathetic responses, vestibulo-sympathetic reflex, and concentrations of norepinephrine and acetylcholine. We formulate an inverse...... in healthy and hypertensive elderly people the hysteresis loop shifts to higher blood pressure values and its area is diminished. Finally, for hypertensive elderly people the hysteresis loop is generally not closed indicating that during postural change from sitting to standing, the blood pressure resettles......During orthostatic stress, arterial and cardiopulmonary baroreflexes play a key role in maintaining arterial pressure by regulating heart rate. This study, presents a mathematical model that can predict the dynamics of heart rate regulation in response to postural change from sitting to standing...

  3. Dicty_cDB: FC-AC21 [Dicty_cDB

    Lifescience Database Archive (English)

    Full Text Available FC (Link to library) FC-AC21 (Link to dictyBase) - - - Contig-U15104-1 FC-AC21E (Li...nk to Original site) - - - - - - FC-AC21E 527 Show FC-AC21 Library FC (Link to library) Clone ID FC-AC21 (Link to dict...yBase) Atlas ID - NBRP ID - dictyBase ID - Link to Contig Contig-U15104-1 Original site URL http://dict...ce KDSLDVIIFPEMVKLVGLTPNTMEKVLTYFQDNDTIDLSTFPMEIQVEQLSGKYIFICTH KQKDQRCGYCGPILVDQLRDQIKERSLEKEIQVFGTSHVGGHKY... Frames) Frame A: KDSLDVIIFPEMVKLVGLTPNTMEKVLTYFQDNDTIDLSTFPMEIQVEQLSGKYIFICTH KQ

  4. Behavioral correlates of heart rates of free-living Greater White-fronted Geese

    Science.gov (United States)

    Ely, Craig R.; Ward, D.H.; Bollinger, K.S.

    1999-01-01

    We simultaneously monitored the heart rate and behavior of nine free-living Greater White-fronted Geese (Anser albifrons) on their wintering grounds in northern California. Heart rates of wild geese were monitored via abdominally-implanted radio transmitters with electrodes that received electrical impulses of the heart and emitted a radio signal with each ventricular contraction. Post-operative birds appeared to behave normally, readily rejoining flocks and flying up to 15 km daily from night-time roost sites to feed in surrounding agricultural fields. Heart rates varied significantly among individuals and among behaviors, and ranged from less than 100 beats per minute (BPM) during resting, to over 400 BPM during flight. Heart rates varied from 80 to 140 BPM during non-strenuous activities such as walking, feeding, and maintenance activities, to about 180 BPM when birds became alert, and over 400 BPM when birds were startled, even if they did not take flight. Postflight heart rate recovery time averaged postures, as heart rates were context-dependent, and were highest in initial encounters among individuals. Instantaneous measures of physiological parameters, such as heart rate, are often better indicators of the degree of response to external stimuli than visual observations and can be used to improve estimates of energy expenditure based solely on activity data.

  5. Effects of gratitude meditation on neural network functional connectivity and brain-heart coupling.

    Science.gov (United States)

    Kyeong, Sunghyon; Kim, Joohan; Kim, Dae Jin; Kim, Hesun Erin; Kim, Jae-Jin

    2017-07-11

    A sense of gratitude is a powerful and positive experience that can promote a happier life, whereas resentment is associated with life dissatisfaction. To explore the effects of gratitude and resentment on mental well-being, we acquired functional magnetic resonance imaging and heart rate (HR) data before, during, and after the gratitude and resentment interventions. Functional connectivity (FC) analysis was conducted to identify the modulatory effects of gratitude on the default mode, emotion, and reward-motivation networks. The average HR was significantly lower during the gratitude intervention than during the resentment intervention. Temporostriatal FC showed a positive correlation with HR during the gratitude intervention, but not during the resentment intervention. Temporostriatal resting-state FC was significantly decreased after the gratitude intervention compared to the resentment intervention. After the gratitude intervention, resting-state FC of the amygdala with the right dorsomedial prefrontal cortex and left dorsal anterior cingulate cortex were positively correlated with anxiety scale and depression scale, respectively. Taken together, our findings shed light on the effect of gratitude meditation on an individual's mental well-being, and indicate that it may be a means of improving both emotion regulation and self-motivation by modulating resting-state FC in emotion and motivation-related brain regions.

  6. Comparison of the Fc fragment from a human IgG1 and its CH2, pFc', and tFc' subfragments. A study using reductive methylation and 13C NMR

    International Nuclear Information System (INIS)

    Jentoft, J.E.; Rayford, R.

    1989-01-01

    The Fc fragment of a human monoclonal IgG1 was compared with subfragments containing (a) the intact CH2 domain (CH2 fragment) or (b) the intact CH3 domain (pFc' and tFc' fragments). All fragments were reductively 13 C-methylated and their resulting dimethyllysyl resonances characterized in 0.1 M KCl as a function of pH by 13 C NMR spectroscopy. Seven resonances were characterized for the 18 lysine residues of the Fc fragment, eight for the 12 lysines of the CH2 fragment, and five each for the 9 lysines of the pFc' and the 6 lysines of the tFc' fragments, respectively. The multiplicity of resonances indicates that the lysine residues in each fragment exist in a variety of microenvironments and that the fragments are all highly structured. The correspondence between 6 of the 12 or 13 perturbed lysine residues in the Fc fragment and the smaller subfragments indicates that the conformation of the CH2 and CH3 domains is largely unchanged in the smaller fragments. However, in addition to three lysines at the CH2-CH3 domain interface, whose environments were known to be disrupted in the smaller fragments, three or four lysine residues have somewhat different properties in the Fc fragment and in the subfragments, indicating that some local perturbations are included in the domain structure in the subfragments

  7. Relationship between heart rate and preference for tempo of music.

    Science.gov (United States)

    Iwanaga, M

    1995-10-01

    People prefer music with tempi ranging from 70 to 100 cycles per minute similar to that of adults' heart rate within normal daily situations. Previous studies of the relation between preferred tempi and heart rates using a pure tone also have indicated that subjects tended to prefer tempi similar to their heart rates. The present study examined this relationship using a musical piece (the theme of "It's a small world") as a stimulus. 14 undergraduate women were subjects who searched for their favorite tempi by controlling the musical tempo by themselves. The most preferred tempo was close to their cycle of heart beats, however, tempi that were one and a half and twice as fast as the heart rate were less preferred in the present study than in a previous study using a tone. Subjects preferred faster tempi in the descending series of stimuli than in the ascending one, and hence were influenced by the initial value of the tempo in the trial sequence. The effects due to the differences of the meaning of the stimuli are considered.

  8. Dicty_cDB: FC-AY04 [Dicty_cDB

    Lifescience Database Archive (English)

    Full Text Available FC (Link to library) FC-AY04 (Link to dictyBase) - - - Contig-U16521-1 FC-AY04Z (Li...nk to Original site) - - FC-AY04Z 583 - - - - Show FC-AY04 Library FC (Link to library) Clone ID FC-AY04 (Link to dict...yBase) Atlas ID - NBRP ID - dictyBase ID - Link to Contig Contig-U16521-1 Original site URL http://dict...10 4 CA753827 |AF402814_1 ( AF402814 ) 40S ribosomal protein S6 [Ictalurus puncta...0.00 m_ : 1.00 92.0 %: cytoplasmic 4.0 %: mitochondrial 4.0 %: nuclear >> prediction for FC-AY04 is cyt 5' e

  9. Dicty_cDB: FC-AK01 [Dicty_cDB

    Lifescience Database Archive (English)

    Full Text Available FC (Link to library) FC-AK01 (Link to dictyBase) - - - Contig-U15038-1 FC-AK01E (Li...nk to Original site) - - - - - - FC-AK01E 996 Show FC-AK01 Library FC (Link to library) Clone ID FC-AK01 (Link to dict...yBase) Atlas ID - NBRP ID - dictyBase ID - Link to Contig Contig-U15038-1 Original site URL http://dict...s clone omyk-evn... 172 6e-79 AF401557_1( AF401557 |pid:none) Ictalurus punctatus...reticulum 4.0 %: vacuolar >> prediction for FC-AK01 is mit 5' end seq. ID - 5' end seq. - Length of 5' end s

  10. One hour effects of salbutamol and formoterol on blood pressure, heart rate and oxygen saturation in asthmatics

    Directory of Open Access Journals (Sweden)

    Geraldo Andrade Capuchinho-Júnior

    2008-05-01

    Full Text Available Aim: To analyse systolic (SBP and diastolic blood pressure (DBP, partial oxygen saturation (SpO2 and heart rate (HR disorders for an hour after short and long acting ß2-agonists. Material and methods: Twenty-four severe persistent asthma Pulmonology outpatients at Hospital Universitario Gaffree e Guinle were selected. SBP, DBP, SpO2 and HR values were determined before and after 400 μg of salbutamol and 12 μg of formoterol, on different days, with a minimum interval of 24 hours. Results: All patients showed ventilatory obstruction, as seen by a reduced FEV1/FVC ratio. There was no statistical SBP/DBP/HR difference after bronchodilator agents, but SpO2 increased with salbutamol. Conclusion: A standard dose of salbutamol and formoterol does not cause haemodynamic disorder. Resumo: Objectivo: Analisar os possíveis efeitos do uso de β-2-agonistas, de curta e longa duração, nas pressões arteriais sistólica (PAS e diastólica (PAD, na saturação parcial de oxigénio (SpO2 e na frequência cardíaca (FC, durante o período de uma hora. Material e métodos: Vinte e quatro doentes com asma persistente grave, em tratamento no ambulatório de Pneumologia do Hospital Universitário Gaffrée e Guinle, foram seleccionados para um ensaio clínico sequencial e cruzado. Os valores da PAS, PAD, SpO2 e FC foram registados antes e após o uso de broncodilatadores, salbutamol 400 μg e formoterol 12 μg, em dias diferentes, com intervalo mínimo de 24 horas. Resultados: Todos os doentes apresentaram distúrbio ventilatório obstrutivo, identificado pela redução da relação entre o volume expiratório forçado no primeiro segundo (VEMS e a capacidade vital forçada (CVF. Após o uso de substância broncodilatadora, não houve variação significativa nas PAS e PAD, nem na FC; porém, a SpO2 aumentou com o uso de salbutamol. Conclusão: Não foram observadas

  11. NRG1-Fc improves metabolic health via dual hepatic and central action.

    Science.gov (United States)

    Zhang, Peng; Kuang, Henry; He, Yanlin; Idiga, Sharon O; Li, Siming; Chen, Zhimin; Yang, Zhao; Cai, Xing; Zhang, Kezhong; Potthoff, Matthew J; Xu, Yong; Lin, Jiandie D

    2018-03-08

    Neuregulins (NRGs) are emerging as an important family of signaling ligands that regulate glucose and lipid homeostasis. NRG1 lowers blood glucose levels in obese mice, whereas the brown fat-enriched secreted factor NRG4 protects mice from high-fat diet-induced insulin resistance and hepatic steatosis. However, the therapeutic potential of NRGs remains elusive, given the poor plasma half-life of the native ligands. Here, we engineered a fusion protein using human NRG1 and the Fc domain of human IgG1 (NRG1-Fc) that exhibited extended half-life in circulation and improved potency in receptor signaling. We evaluated its efficacy in improving metabolic parameters and dissected the mechanisms of action. NRG1-Fc treatment triggered potent AKT activation in the liver, lowered blood glucose, improved insulin sensitivity, and suppressed food intake in obese mice. NRG1-Fc acted as a potent secretagogue for the metabolic hormone FGF21; however, the latter was largely dispensable for its metabolic effects. NRG1-Fc directly targeted the hypothalamic POMC neurons to promote membrane depolarization and increase firing rate. Together, NRG1-Fc exhibits improved pharmacokinetic properties and exerts metabolic benefits through dual inhibition of hepatic gluconeogenesis and caloric intake.

  12. Heart-Rate Recovery Index Is Impaired in Behçet's Disease

    Science.gov (United States)

    Kaya, Ergun Baris; Yorgun, Hikmet; Akdogan, Ali; Ates, Ahmet Hakan; Canpolat, Ugur; Sunman, Hamza; Aytemir, Kudret; Tokgozoglu, Lale; Kabakci, Giray; Calguneri, Meral; Ozkutlu, Hilmi; Oto, Ali

    2009-01-01

    Behçet's disease, a multisystemic inflammatory disorder, has been associated with a number of cardiovascular dysfunctions, including ventricular arrhythmias and sudden cardiac death. Heart-rate recovery after exercise can provide both an estimate of impaired parasympathetic tone and a prognosis in regard to all-cause and cardiovascular death. The aim of our study was to evaluate heart-rate recovery in Behçet's disease From January through July 2008, we examined at our outpatient clinic and prospectively enrolled 30 consecutive patients with Behçet's disease and 50 healthy control participants who were matched for age and sex. Basal electrocardiography, echocardiography, and treadmill exercise testing were performed in all patients and control participants. The heart-rate recovery index was calculated in the usual manner, by subtracting the 1st-minute (Rec1), 2nd-minute (Rec2), and 3rd-minute (Rec3) recovery heart rates from the maximal heart rate after exercise stress testing. Patients with Behçet's disease exhibited significantly lower heart-rate recovery numbers, compared with healthy control participants: Rec1, 24.28 ± 8.2 vs 34.4 ± 7.6, P = 0.002; Rec2, 49.28 ± 11.2 vs 57.5 ± 7.0, P < 0.05; and Rec3, 56.2 ± 12.11 vs 67.4 ± 8.7, P = 0.014. To our knowledge, this is the 1st study that shows an impaired heart-rate recovery index (indicative of reduced parasympathetic activity) among patients with Behçet's disease. Given the independent prognostic value of the heart-rate recovery index, our results may explain the increased occurrence of arrhythmias and sudden cardiac death in Behçet's patients. Therefore, this index may be clinically useful in the identification of high-risk patients. PMID:19693299

  13. Do high fetal catecholamine levels affect heart rate variability and ...

    African Journals Online (AJOL)

    Objectives. To deternrine the relationship between Umbilical arterial catecholamine levels and fetal heart rate variability and meconium passage. Study design. A prospective descriptive study was perfonned. Umbilical artery catecholamine levels were measured in 55 newborns and correlated with fetal heart rate before ...

  14. Fetal Heart Rate Monitoring during Labor

    Science.gov (United States)

    ... What are the types of monitoring? • How is auscultation performed? • How is electronic fetal monitoring performed? • How ... methods of fetal heart rate monitoring in labor. Auscultation is a method of periodically listening to the ...

  15. Dicty_cDB: FC-BF01 [Dicty_cDB

    Lifescience Database Archive (English)

    Full Text Available FC (Link to library) FC-BF01 (Link to dictyBase) - - - Contig-U15105-1 FC-BF01Z (Li...nk to Original site) - - FC-BF01Z 674 - - - - Show FC-BF01 Library FC (Link to library) Clone ID FC-BF01 (Link to dict...yBase) Atlas ID - NBRP ID - dictyBase ID - Link to Contig Contig-U15105-1 Original site URL http://dict...402813_1( AF402813 |pid:none) Ictalurus punctatus 40S ribosomal ... 260 3e-68 AJ783868_1( AJ783868 |pid:none...lasmic 8.0 %: mitochondrial 4.0 %: nuclear >> prediction for FC-BF01 is cyt 5' end seq. ID - 5' end seq. - L

  16. Dicty_cDB: FC-BC16 [Dicty_cDB

    Lifescience Database Archive (English)

    Full Text Available FC (Link to library) FC-BC16 (Link to dictyBase) - - - Contig-U15105-1 FC-BC16Z (Li...nk to Original site) - - FC-BC16Z 620 - - - - Show FC-BC16 Library FC (Link to library) Clone ID FC-BC16 (Link to dict...yBase) Atlas ID - NBRP ID - dictyBase ID - Link to Contig Contig-U15105-1 Original site URL http://dict...4 2e-66 AY961522_1( AY961522 |pid:none) Lysiphlebus testaceipes ribosomal ... 254 2e-66 AF402813_1( AF402813 |pid:none) Ict...hondrial 4.0 %: nuclear >> prediction for FC-BC16 is cyt 5' end seq. ID - 5' end seq. - Length of 5' end seq

  17. [The influence of physical exercise on heart rate variability].

    Science.gov (United States)

    Gajek, Jacek; Zyśko, Dorota; Negrusz-Kawecka, Marta; Halawa, Bogumił

    2003-03-01

    Heart rate variability is controlled by the influence of autonomic nervous system, whereas one part of the system modulates the activity of the other. There is evidence of increased sympathetic activity in patients (pts) with essential hypertension. The aim of the study was to assess the persisting influence of increased sympathetic activity 30 min after moderate physical exercise on heart rate variability in patients with arterial hypertension. The study was performed in 19 patients (10 women, mean age 52.7 +/- 9.5 years and 9 men, mean age 37.7 +/- 8.8 years) with stage I (6 pts) and stage II (13 pts) arterial hypertension. All studied pts had sinus rhythm, were free of diabetes, coronary heart disease and congestive heart failure. 24-hour Holter monitoring was performed and for 30 min before the exercise test the pts stayed in supine rest. The exercise tests were performed between 10 and 11 a.m. Immediately after the exercise all pts stayed in supine position for 30 min. The heart rate variability parameters were studied using Holter monitoring system Medilog Optima Jet and were then analysed statistically. The mean energy expenditure during the exercise was 5.8 +/- 1.1 METs and the maximal heart rate was 148.1 +/- 20.3 bpm. All studied HRV parameters were significantly different in the assessed time period compared to the baseline values (p < 0.001). Significant correlation was found between the age of the studied patients and the mean RR interval, what can be considered as a hyperkinetic (hyperadrenergic) circulatory status and shorter RR interval in younger pts. Significant negative correlation between the age and SDNN parameter (r = -0.65, p < 0.001), 30 min after the exercise mirrors the prolonged adrenergic influence in older pts. The present study shows that the influence of moderate physical exercise on heart rate variability in pts with essential hypertension is extended over 30 min period after exercise and is more pronounced in older pts. The studies

  18. HAL/S-FC compiler system specifications

    Science.gov (United States)

    1976-01-01

    This document specifies the informational interfaces within the HAL/S-FC compiler, and between the compiler and the external environment. This Compiler System Specification is for the HAL/S-FC compiler and its associated run time facilities which implement the full HAL/S language. The HAL/S-FC compiler is designed to operate stand-alone on any compatible IBM 360/370 computer and within the Software Development Laboratory (SDL) at NASA/JSC, Houston, Texas.

  19. The use of heart rate turbulence and heart rate variability in the assessment of autonomic regulation and circadian rhythm in patients with systemic lupus erythematosus without apparent heart disease.

    Science.gov (United States)

    Poliwczak, A R; Waszczykowska, E; Dziankowska-Bartkowiak, B; Koziróg, M; Dworniak, K

    2018-03-01

    Background Systemic lupus erythematosus is a progressive autoimmune disease. There are reports suggesting that patients even without overt signs of cardiovascular complications have impaired autonomic function. The aim of this study was to assess autonomic function using heart rate turbulence and heart rate variability parameters indicated in 24-hour ECG Holter monitoring. Methods Twenty-six women with systemic lupus erythematosus and 30 healthy women were included. Twenty-four hour ambulatory ECG-Holter was performed in home conditions. The basic parameters of heart rate turbulence and heart rate variability were calculated. The analyses were performed for the entire day and separately for daytime activity and night time rest. Results There were no statistically significant differences in the basic anthropometric parameters. The mean duration of disease was 11.52 ± 7.42. There was a statistically significant higher turbulence onset (To) value in patients with systemic lupus erythematosus, median To = -0.17% (minimum -1.47, maximum 3.0) versus To = -1.36% (minimum -4.53, maximum -0.41), P lupus erythematosus group than in the healthy controls, including SDANN and r-MSSD and p50NN. Concerning the morning activity and night resting periods, the results were similar as for the whole day. In the control group, higher values in morning activity were noted for parameters that characterise sympathetic activity, especially SDANN, and were significantly lower for parasympathetic parameters, including r-MSSD and p50NN, which prevailed at night. There were no statistically significant changes for systemic lupus erythematosus patients for p50NN and low and very low frequency. There was a positive correlation between disease duration and SDNN, R = 0.417; P < 0.05 and SDANN, R = 0.464; P < 0.05, a negative correlation between low/high frequency ratio and r-MSSD, R = -0.454; P < 0.05; p50NN, R = -0.435; P < 0.05 and high frequency

  20. Correlation of heart rate and radionuclide index of left ventricular contraction and relaxation

    International Nuclear Information System (INIS)

    Adachi, Haruhiko; Sugihara, Hiroki; Nakagawa, Hiroaki; Inagaki, Suetsugu; Kubota, Yasushi; Nakagawa, Masao

    1990-01-01

    Since the cardiac function indices derived from radionuclide ventriculography (RNV) are considered to depend on the heart rate, we studied the relationship between systolic or diastolic indices and heart rates in patients with normal RNV and devised a method of correcting these indices according to the heart rate. For the systolic indices, the heart rate showed significant correlation with ET (r=-0.640), PER (r=0.791) and TPE (r=-0.401) but not with EF, 1/3 EF, MNSER or 1/3 MNSER. For the diastolic indices, the heart rate correlated well with FT (r=-0.938), RFT (r=-0.736), SFT (r=-0.803), 1/3 FF (r=-0.758), PFR (r=0.759), 1/3 PFR (r=0.742) and TPF (r=-0.389) but not with AFT, 1/3 MNDFR or AFF. These results indicate that many systolic and diastolic indices derived from RNV are affected by the heart rate, So when cardiac function is evaluated with the use of radionuclide indices, those which are independent of the heart rate should be used, or they should be corrected for the heart rate. As a method of correction, we proposed a rotating method obtained by manipulation of the regression equation of heart rates and indices. This new method is certain and easier to use when the correcting equations are set into a computer program. (author)

  1. AUTONOMIC CONTROL OF HEART RATE AFTER EXERCISE IN TRAINED WRESTLERS

    Directory of Open Access Journals (Sweden)

    Carlos F Henríquez

    2013-04-01

    Full Text Available The objective of this study was to establish differences in vagal reactivation, through heart rate recovery and heart rate variability post exercise, in Brazilian jiu-jitsu wrestlers (BJJW. A total of 18 male athletes were evaluated, ten highly trained (HT and eight moderately trained (MT, who performed a maximum incremental test. At the end of the exercise, the R-R intervals were recorded during the first minute of recovery. We calculated heart rate recovery (HRR60s, and performed linear and non-linear (standard deviation of instantaneous beat-to-beat R-R interval variability – SD1 analysis of heart rate variability (HRV, using the tachogram of the first minute of recovery divided into four segments of 15 s each (0-15 s, 15-30 s, 30-45 s, 45-60 s. Between HT and MT individuals, there were statistically significant differences in HRR60s (p <0.05 and in the non linear analysis of HRV from SD130-45s (p <0.05 and SD145-60s (p <0.05. The results of this research suggest that heart rate kinetics during the first minute after exercise are related to training level and can be used as an index for autonomic cardiovascular control in BJJW.

  2. Design of heart rate monitor based on piezoelectric sensor using an Arduino

    Science.gov (United States)

    Setyowati, Veni; Muninggar, Jodelin; Shanti. N. A, Made R. S.

    2017-01-01

    Reading of result heart rate using an acoustic stethoscope needs a particular skill, quiet environment, and hearing sensitivity. This project had the purpose design of a user-friendly automatic heart rate monitor and especially in a noisy area which to eliminate problems and incorrect reading of result. The liquid crystal display shows a heart rate as a result of measurements. The design of the heart rate monitor has two main parts; the signal recorder that a piezoelectric sensor, a filter, and an amplifier as recorder. The second parts was Arduino microcontroller with reinforced. Besides, three supporting buttons provided as the manual switches, the ‘on’, the ‘start’, and ‘reset’ buttons. The values acquired from the heart rate monitor indicate that those were on the Vernier BPS-BTA value range. The measurement error factor of the heart rate monitor then compared to the Vernier BPS-BTA test device was 3.15%. Besides, the value of statistical independent-test indicates that there is no significant difference (P = 0.971) between the heart rate monitor device and the Vernier BPS-BTA. In conclusion, this device was ready to be used because it has almost the same accuracy with the standart device.

  3. A healthy heart is not a metronome: an integrative review of the heart's anatomy and heart rate variability.

    Science.gov (United States)

    Shaffer, Fred; McCraty, Rollin; Zerr, Christopher L

    2014-01-01

    Heart rate variability (HRV), the change in the time intervals between adjacent heartbeats, is an emergent property of interdependent regulatory systems that operate on different time scales to adapt to challenges and achieve optimal performance. This article briefly reviews neural regulation of the heart, and its basic anatomy, the cardiac cycle, and the sinoatrial and atrioventricular pacemakers. The cardiovascular regulation center in the medulla integrates sensory information and input from higher brain centers, and afferent cardiovascular system inputs to adjust heart rate and blood pressure via sympathetic and parasympathetic efferent pathways. This article reviews sympathetic and parasympathetic influences on the heart, and examines the interpretation of HRV and the association between reduced HRV, risk of disease and mortality, and the loss of regulatory capacity. This article also discusses the intrinsic cardiac nervous system and the heart-brain connection, through which afferent information can influence activity in the subcortical and frontocortical areas, and motor cortex. It also considers new perspectives on the putative underlying physiological mechanisms and properties of the ultra-low-frequency (ULF), very-low-frequency (VLF), low-frequency (LF), and high-frequency (HF) bands. Additionally, it reviews the most common time and frequency domain measurements as well as standardized data collection protocols. In its final section, this article integrates Porges' polyvagal theory, Thayer and colleagues' neurovisceral integration model, Lehrer et al.'s resonance frequency model, and the Institute of HeartMath's coherence model. The authors conclude that a coherent heart is not a metronome because its rhythms are characterized by both complexity and stability over longer time scales. Future research should expand understanding of how the heart and its intrinsic nervous system influence the brain.

  4. Heart rate variability in bipolar disorder

    DEFF Research Database (Denmark)

    Faurholt-Jepsen, Maria; Kessing, Lars Vedel; Munkholm, Klaus

    2017-01-01

    Background Heart rate variability (HRV) has been suggested reduced in bipolar disorder (BD) compared with healthy individuals (HC). This meta-analysis investigated: HRV differences in BD compared with HC, major depressive disorder or schizophrenia; HRV differences between affective states; HRV...

  5. Effects of hot-iron branding on heart rate, breathing rate and behaviour of anaesthetised Steller sea lions.

    Science.gov (United States)

    Walker, K A; Mellish, J E; Weary, D M

    2011-10-01

    This study assessed the heart rate, breathing rate and behavioural responses of 12 juvenile Steller sea lions during hot-iron branding under isoflurane anaesthesia. Physiological and behavioural measures were recorded in four periods: baseline (five minutes), sham branding (one minute), branding (approximately 2.7 minutes) and postbranding (five minutes). No difference in heart rate was noted from baseline to sham branding, but heart rate increased from mean (sem) 78.3 (2.4) bpm in the baseline period to 85.6 (2.5) bpm in the branding period. Heart rate remained elevated in the postbranding period, averaging 84.7 (2.5) bpm. Breathing rate averaged 2.5 (1.0) breaths/minute in the baseline and sham branding periods increased to 8.9 (1.0) breaths/minute during branding, but returned to baseline by the postbranding period. Behaviourally, half of the sea lions exhibited trembling and head and shoulder movements during branding.

  6. The clinical significance of detection to heart rate deceleration capacity and heart rate variability in patients with chronic heart failure

    Directory of Open Access Journals (Sweden)

    Jiang-rong Zhou

    2015-01-01

    Full Text Available Objective: To study the change of heart rate deceleration capacity ( DC and heart rate variability in patients with chronic heart failure (CHF and its relationship with left ventricular ejection fraction (LVEF. Methods: DC, LVEF, time and frequency domain parameters of HRV were measured in 66 patients with CHF and 34 healthy adults (control group by using 24h Holter recordings and Echocardiography. The standard deviation of normal R-R intervals( SDNN, squares of differences between adjacent NN intervals ( RMSSD,low frequency power( LFn and high frequency power( HFn and the changes of LVEF were compared between  the two groups,the relationship between DC,LVEF and HRV were studied in patients with CHF. Results: The median value of DC in the patients with CHF was significantly lower than that in control group( 3.1 ± 2.4 ms vs 7.2 ± 1.3 ms,P <0.01.Incidence of abnormal DC in the CHF group was 57.5%,which was significantly higher than that in the control group (P <0.01.The HRV index, including SDNN、RMSSD、LFn、HFn, in the CHF group was significantly lower than that in normal control group (P < 0.01. Significant positive correlation between HRV index and LVEF were confirmed (P < 0.01. Conclusions: DC and HRV index are lower in patients with CHF and have a good correlation with the left ventricular ejection fraction.

  7. Heart Rate Variability Interventions for Concussion and Rehabilitation

    Directory of Open Access Journals (Sweden)

    Robert Lake Conder

    2014-08-01

    Full Text Available The study of Heart Rate Variability (HRV has emerged as an essential component of cardiovascular health, as well as a physiological mechanism by which one can increase the interactive communication between the cardiac and the neurocognitive systems (i.e., the body and the brain. It is well-established that lack of heart rate variability implies cardiopathology, morbidity, reduced quality-of-life, and precipitous mortality. On the positive, optimal heart rate variability has been associated with good cardiovascular health, autonomic nervous system (ANS control, emotional regulation, and enhanced neurocognitive processing. In addition to health benefits, optimal HRV has been shown to improve neurocognitive performance by enhancing focus, visual acuity and readiness, and by promoting emotional regulation needed for peak performance. In concussed athletes and soldiers, concussions not only alter brain connectivity, but also alter cardiac functioning and impair cardiovascular performance upon exertion. Altered sympathetic and parasympathetic balance in the ANS has been postulated as a critical factor in refractory Post Concussive Syndrome (PCS. This article will review both the pathological aspects of reduced heart rate variability on athletic performance, as well as the cardiovascular and cerebrovascular components of concussion and PCS. Additionally, this article will review interventions with HRV biofeedback (HRV BFB training as a promising and underutilized treatment for sports and military-related concussion. Finally, this article will review research and promising case studies pertaining to use of HRV BFB for enhancement of cognition and performance, with applicability to concussion rehabilitation.

  8. The Effect of Heart Rate on the Heart Rate Variability Response to Autonomic Interventions

    Directory of Open Access Journals (Sweden)

    George E Billman

    2013-08-01

    Full Text Available Heart rate variability (HRV, the beat-to-beat variation in either heart rate (HR or heart period (R-R interval, has become a popular clinical and investigational tool to quantify cardiac autonomic regulation. However, it is not widely appreciated that, due to the inverse curvilinear relationship between HR and R-R interval, HR per se can profoundly influence HRV. It is, therefore, critical to correct HRV for the prevailing HR particularly, as HR changes in response to autonomic neural activation or inhibition. The present study evaluated the effects of HR on the HRV response to autonomic interventions that either increased (submaximal exercise, n = 25 or baroreceptor reflex activation, n = 20 or reduced (pharmacological blockade: β-adrenergic receptor, muscarinic receptor antagonists alone and in combination, n = 25, or bilateral cervical vagotomy, n = 9 autonomic neural activity in a canine model. Both total (RR interval standard deviation, RRSD and the high frequency variability (HF, 0.2 to 1.04 Hz were determined before and in response to an autonomic intervention. All interventions that reduced or abolished cardiac parasympathetic regulation provoked large reductions in HRV even after HR correction [division by mean RRsec or (mean RRsec2 for RRSD and HF, respectively] while interventions that reduced HR yielded mixed results. β-adrenergic receptor blockade reduced HRV (RRSD but not HF while both RRSD and HF increased in response to increases in arterial blood (baroreceptor reflex activation even after HR correction. These data suggest that the physiological basis for HRV is revealed after correction for prevailing HR and, further, that cardiac parasympathetic activity is responsible for a major portion of the HRV in the dog.

  9. Dicty_cDB: FC-IC0102 [Dicty_cDB

    Lifescience Database Archive (English)

    Full Text Available FC-IC (Link to library) FC-IC0102 (Link to dictyBase) - - - Contig-U16527-1 FC-IC01...02F (Link to Original site) FC-IC0102F 434 - - - - - - Show FC-IC0102 Library FC-IC (Link to library) Clone ...ID FC-IC0102 (Link to dictyBase) Atlas ID - NBRP ID - dictyBase ID - Link to Contig Contig-U16527-1 Original site URL http://dict... (bits) Value N AB088483 |AB088483.1 Dictyostelium discoideum gene for gamete and mating-type specific prote...oducing significant alignments: (bits) Value AB088483_1( AB088483 |pid:none) Dictyostelium discoideum gmsA g

  10. Dicty_cDB: FC-AA02 [Dicty_cDB

    Lifescience Database Archive (English)

    Full Text Available FC (Link to library) FC-AA02 (Link to dictyBase) - - - Contig-U16527-1 FC-AA02Z (Li...nk to Original site) - - FC-AA02Z 458 - - - - Show FC-AA02 Library FC (Link to library) Clone ID FC-AA02 (Link to dic...linum small subunit ribosomal RNA gene, partial sequence. 149 2e-47 2 AY179984 |AY179984.1 Uncultured alveo... CP000930_2283( CP000930 |pid:none) Heliobacterium modesticaldum Ic... 33 2.3 AP009386_1894( AP009386 |pid:none) Burkholderia multi... EU955514 |pid:none) Zea mays clone 1535262 hypothetica... 50 2e-05 BA000023_1285

  11. Assessing the Heterogeneity of the Fc-Glycan of a Therapeutic Antibody Using an engineered FcγReceptor IIIa-Immobilized Column.

    Science.gov (United States)

    Kiyoshi, Masato; Caaveiro, Jose M M; Tada, Minoru; Tamura, Hiroko; Tanaka, Toru; Terao, Yosuke; Morante, Koldo; Harazono, Akira; Hashii, Noritaka; Shibata, Hiroko; Kuroda, Daisuke; Nagatoishi, Satoru; Oe, Seigo; Ide, Teruhiko; Tsumoto, Kouhei; Ishii-Watabe, Akiko

    2018-03-02

    The N-glycan moiety of IgG-Fc has a significant impact on multifaceted properties of antibodies such as in their effector function, structure, and stability. Numerous studies have been devoted to understanding its biological effect since the exact composition of the Fc N-glycan modulates the magnitude of effector functions such as the antibody-dependent cell mediated cytotoxicity (ADCC), and the complement-dependent cytotoxicity (CDC). To date, systematic analyses of the properties and influence of glycan variants have been of great interest. Understanding the principles on how N-glycosylation modulates those properties is important for the molecular design, manufacturing, process optimization, and quality control of therapeutic antibodies. In this study, we have separated a model therapeutic antibody into three fractions according to the composition of the N-glycan by using a novel FcγRIIIa chromatography column. Notably, Fc galactosylation was a major factor influencing the affinity of IgG-Fc to the FcγRIIIa immobilized on the column. Each antibody fraction was employed for structural, biological, and physicochemical analysis, illustrating the mechanism by which galactose modulates the affinity to FcγRIIIa. In addition, we discuss the benefits of the FcγRIIIa chromatography column to assess the heterogeneity of the N-glycan.

  12. Novel Fingertip Image-Based Heart Rate Detection Methods for a Smartphone

    Directory of Open Access Journals (Sweden)

    Rifat Zaman

    2017-02-01

    Full Text Available We hypothesize that our fingertip image-based heart rate detection methods using smartphone reliably detect the heart rhythm and rate of subjects. We propose fingertip curve line movement-based and fingertip image intensity-based detection methods, which both use the movement of successive fingertip images obtained from smartphone cameras. To investigate the performance of the proposed methods, heart rhythm and rate of the proposed methods are compared to those of the conventional method, which is based on average image pixel intensity. Using a smartphone, we collected 120 s pulsatile time series data from each recruited subject. The results show that the proposed fingertip curve line movement-based method detects heart rate with a maximum deviation of 0.0832 Hz and 0.124 Hz using time- and frequency-domain based estimation, respectively, compared to the conventional method. Moreover, another proposed fingertip image intensity-based method detects heart rate with a maximum deviation of 0.125 Hz and 0.03 Hz using time- and frequency-based estimation, respectively.

  13. Patterns of Interspecific Variation in the Heart Rates of Embryonic Reptiles

    Science.gov (United States)

    Du, Wei-Guo; Ye, Hua; Zhao, Bo; Pizzatto, Ligia; Ji, Xiang; Shine, Richard

    2011-01-01

    New non-invasive technologies allow direct measurement of heart rates (and thus, developmental rates) of embryos. We applied these methods to a diverse array of oviparous reptiles (24 species of lizards, 18 snakes, 11 turtles, 1 crocodilian), to identify general influences on cardiac rates during embryogenesis. Heart rates increased with ambient temperature in all lineages, but (at the same temperature) were faster in lizards and turtles than in snakes and crocodilians. We analysed these data within a phylogenetic framework. Embryonic heart rates were faster in species with smaller adult sizes, smaller egg sizes, and shorter incubation periods. Phylogenetic changes in heart rates were negatively correlated with concurrent changes in adult body mass and residual incubation period among the lizards, snakes (especially within pythons) and crocodilians. The total number of embryonic heart beats between oviposition and hatching was lower in squamates than in turtles or the crocodilian. Within squamates, embryonic iguanians and gekkonids required more heartbeats to complete development than did embryos of the other squamate families that we tested. These differences plausibly reflect phylogenetic divergence in the proportion of embryogenesis completed before versus after laying. PMID:22174948

  14. Heart Rate Monitor for Portable MP3 Player.

    Science.gov (United States)

    Kim, Jaywoo; Lee, Mi-Hee; Lee, Hyoung-Ki; Choi, Kiwan; Bang, Seokwon; Kim, Sangryong

    2005-01-01

    This paper presents a photoplethysmography sensor based on a heart rate monitor for a portable MP3 player. Two major design issues are addressed: one is to acquire the sensor signal with a proper amplitude despite a wide range of variation and the other is to handle the noise contaminated signal which is caused by a motion artifact. A benchmarking test with a professional medical photoplethysmography sensor shows that our device performs very well in calculating heart rate even though our photoplethysmography sensor module was designed to be cost effective.

  15. Approximate entropy and point correlation dimension of heart rate variability in healthy subjects

    DEFF Research Database (Denmark)

    Storella, R J; Wood, H W; Mills, K M

    1999-01-01

    The contribution of nonlinear dynamics to heart rate variability in healthy humans was examined using surrogate data analysis. Several measures of heart rate variability were used and compared. Heart rates were recorded for three hours and original data sets of 8192 R-R intervals created. For each...... original data set (n = 34), three surrogate data sets were made by shuffling the order of the R-R intervals while retaining their linear correlations. The difference in heart rate variability between the original and surrogate data sets reflects the amount of nonlinear structure in the original data set....... Heart rate variability was analyzed by two different nonlinear methods, point correlation dimension and approximate entropy. Nonlinearity, though under 10 percent, could be detected with both types of heart rate variability measures. More importantly, not only were the correlations between...

  16. iHeartLift: a closed loop system with bio-feedback that uses music tempo variability to improve heart rate variability.

    Science.gov (United States)

    Ho, Thomas C T; Chen, Xiang

    2011-01-01

    "Musica delenit bestiam feram" translates into "Music soothes the savage beast". There is a hidden truth in this ancient quip passed down from generations. Besides soothing the heart, it also incites the heart to a healthier level of heart rate variability (HRV). In this paper, an approach to use and test music and biofeedback to increase the heart rate variability for people facing daily stress is discussed. By determining the music tempo variability (MTV) of a piece of music and current heart rate variability, iHeartLift is able to compare the 2 trends and locate a musical piece that is suited to increase the user's heart rate variability to a healthier level. With biofeedback, the 2 trends are continuously compared in real-time and the musical piece is changed in accordance with the current comparisons. A study was conducted and it was generally found that HRV can be uplifted by music regardless of language and meaning of musical lyrics but with limitations to musical genre.

  17. Heart rate variability and baroreflex sensitivity in bilateral lung transplant recipients.

    Science.gov (United States)

    Fontolliet, Timothée; Gianella, Pietro; Pichot, Vincent; Barthélémy, Jean-Claude; Gasche-Soccal, Paola; Ferretti, Guido; Lador, Frédéric

    2018-01-09

    The effects of lung afferents denervation on cardiovascular regulation can be assessed on bilateral lung transplantation patients. The high-frequency component of heart rate variability is known to be synchronous with breathing frequency. Then, if heart beat is neurally modulated by breathing frequency, we may expect disappearance of high frequency of heart rate variability in bilateral lung transplantation patients. On 11 patients and 11 matching healthy controls, we measured R-R interval (electrocardiography), blood pressure (Portapres ® ) and breathing frequency (ultrasonic device) in supine rest, during 10-min free breathing, 10-min cadenced breathing (0·25 Hz) and 5-min handgrip. We analysed heart rate variability and spontaneous variability of arterial blood pressure, by power spectral analysis, and baroreflex sensitivity, by the sequence method. Concerning heart rate variability, with respect to controls, transplant recipients had lower total power and lower low- and high-frequency power. The low-frequency/high-frequency ratio was higher. Concerning systolic, diastolic and mean arterial pressure variability, transplant recipients had lower total power (only for cadenced breathing), low frequency and low-frequency/high-frequency ratio during free and cadenced breathing. Baroreflex sensitivity was decreased. Denervated lungs induced strong heart rate variability reduction. The higher low-frequency/high-frequency ratio suggested that the total power drop was mostly due to high frequency. These results support the hypothesis that neural modulation from lung afferents contributes to the high frequency of heart rate variability. © 2018 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  18. Elevated resting heart rate, physical fitness and all-cause mortality

    DEFF Research Database (Denmark)

    Jensen, Magnus Thorsten; Suadicani, Poul; Hein, Hans Ole

    2013-01-01

    To examine whether elevated resting heart rate (RHR) is an independent risk factor for mortality or a mere marker of physical fitness (VO2Max).......To examine whether elevated resting heart rate (RHR) is an independent risk factor for mortality or a mere marker of physical fitness (VO2Max)....

  19. Dicty_cDB: FC-BS24 [Dicty_cDB

    Lifescience Database Archive (English)

    Full Text Available FC (Link to library) FC-BS24 (Link to dictyBase) - - - Contig-U16209-1 FC-BS24Z (Li...nk to Original site) - - FC-BS24Z 721 - - - - Show FC-BS24 Library FC (Link to library) Clone ID FC-BS24 (Link to dict...yBase) Atlas ID - NBRP ID - dictyBase ID - Link to Contig Contig-U16209-1 Original site URL http://dict...nce. 52 9e-12 4 BQ096846 |BQ096846.1 IfHdk00487 Ictalurus furcatus head kidney cDNA library Ict...N SA ;, mRNA sequence. 44 1e-10 4 BM438323 |BM438323.1 IpLvr01076 Liver cDNA library Ictalurus punctatus cDN

  20. Target Heart Rates

    Science.gov (United States)

    ... Check Recipe Certification Program Nutrition Requirements Heart-Check Professional Resources Contact the Heart-Check Certification Program Simple Cooking and Recipes Dining Out Choosing a Restaurant Deciphering ...

  1. Poincare indices for analyzing meditative heart rate signals

    Directory of Open Access Journals (Sweden)

    Atefeh Goshvarpour

    2015-06-01

    Full Text Available Background: Poincare plots are commonly used to study the nonlinear behavior of physiologic signals. The aim of this study is to evaluate the Poincare plot indices of human heart rate signals during meditation. Methods: For this purpose, heart rate time series of eight Chi meditators available in Physionet database were used. Poincare plots with lags of 1 and 6 were constructed, and the ratio of the minor axis to major axis (SD1/SD2 and the area of Poincare plots were calculated for each lag. Results: The results show that the SD1/SD2 ratio increased significantly during meditation compared to that before meditation, especially the index measured from Poincare plots reconstructed with a lag of 6 (p < 0.05. In addition, in both lags, the area of Poincare plots decreased significantly during meditation compared to before meditation (p < 0.05. Conclusion: The comparative dynamic measures of the Poincare plot indices during and before meditation give more insight of the heart rate signals in a specific psychophysiological state.

  2. Heart rate and exercise: An evidence based interpretation

    Directory of Open Access Journals (Sweden)

    Marcos Bezerra de Almeida

    2007-06-01

    Full Text Available a manner as to facilitate clinical and epidemiological interpretation, and its use for prescribing exercise. At rest, HR can be considered a marker of subjects’ autonomic condition, but despite being affected by maximal aerobic power, neither should not be used for estimating the other. It is possible for HR to increase rapidly within just few seconds of exercise as a result of the vagal inhibition refl ex. This kind of situation is quite common in sports in which movements may be short and sudden, such as judo and tennis, and this information could be used for detecting sports talent. During prolonged exercise, HR tends to follow the level of intensity of effort, especially in continuous exercise. Maximum HR determined by equations exhibits signifi cant estimation errors and should be used with caution. Higher values suggest a better prognosis in terms of risk of mortality. Fast recovery of baseline HR after exercise, while indicating low cardiovascular risk, does not necessarily denote good aerobic fi tness. Evidence also suggests that resistance exercises evoke a lower cardiovascular response than endurance exercises. In conclusion, the utilization of HR for the purposes of diagnosis, prognosis or exercise prescription should be evidence based, in order to diminish the risk of interpretation errors, and also to increase applicability. RESUMO Nosso objetivo foi apresentar e discutir a resposta da freqüência cardíaca (FC de modo a favorecer sua interpretação clínica, epidemiológica e para a prescrição do exercício. Em repouso, a FC é um indicador da condição autonômica do indivíduo, e que apesar de ser infl uenciada pela potência aeróbia máxima, não deve ser utilizada para sua determinação. A FC pode aumentar bastante em apenas poucos segundos de exercício em decorrência do refl exo de inibição vagal. Este tipo de situação é comum em esportes cujos movimentos podem ser súbitos e de curta duração, como o judô e

  3. Experimental investigation of small diameter two-phase closed thermosyphons charged with water, FC-84, FC-77 and FC-3283

    International Nuclear Information System (INIS)

    Jouhara, Hussam; Robinson, Anthony J.

    2010-01-01

    An experimental investigation of the performance of thermosyphons charged with water as well as the dielectric heat transfer liquids FC-84, FC-77 and FC-3283 has been carried out. The copper thermosyphon was 200 mm long with an inner diameter of 6 mm, which can be considered quite small compared with the vast majority of thermosyphons reported in the open literature. The evaporator length was 40 mm and the condenser length was 60 mm which corresponds with what might be expected in compact heat exchangers. With water as the working fluid two fluid loadings were investigated, that being 0.6 ml and 1.8 ml, corresponding to approximately half filled and overfilled evaporator section in order to ensure combined pool boiling and thin film evaporation/boiling and pool boiling only conditions, respectively. For the Fluorinert TM liquids, only the higher fill volume was tested as the aim was to investigate pool boiling opposed to thin film evaporation. Generally, the water-charged thermosyphon evaporator and condenser heat transfer characteristics compared well with available predictive correlations and theories. The thermal performance of the water-charged thermosyphon also outperformed the other three working fluids in both the effective thermal resistance as well as maximum heat transport capabilities. Even so, FC-84, the lowest saturation temperature fluid tested, shows marginal improvement in the heat transfer at low operating temperatures. All of the tested Fluorinert TM liquids offer the advantage of being dielectric fluids, which may be better suited for sensitive electronics cooling applications and were all found to provide adequate thermal performance up to approximately 30-50 W after which liquid entrainment compromised their performance.

  4. The effect of FcγRIIA and FcγRIIB on coronary artery lesion formation and intravenous immunoglobulin treatment responses in children with Kawasaki disease

    Science.gov (United States)

    Chang, Ling-Sai; Lo, Mao-Hung; Li, Sung-Chou; Yang, Ming-Yu; Hsieh, Kai-Sheng; Kuo, Ho-Chang

    2017-01-01

    Previous research has found patients with the FcγRIIIB NA1 variant having increased risk of intravenous immunoglobulin (IVIG) resistance in Kawasaki disease (KD). Our previous studies revealed that elevated FcγRIIA expression correlated with the susceptibility of KD patients. We conducted this research to determine whether and how Fcγ receptors affect the susceptibility, IVIG treatment response, and coronary artery lesions (CAL) of KD patients. The activating FcγRIIA and inhibitory FcγRIIB methylation levels of seven patients with KD and four control subjects were examined using HumanMethylation27 BeadChip. We enrolled a total of 44 KD patients and 10 control subjects with fevers. We performed real-time RT-PCR to determine the FcγRIIA and FcγRIIB expression levels, as well as a luciferase assay of FcγRIIA. We found a considerable increase in methylation of both FcγRIIA and FcγRIIB in KD patients undergoing IVIG treatment. Promoter methylation of FcγRIIA inhibited reporter activity in K562 cells using luciferase assay. The FcγRIIB mRNA expression levels were not found to increase susceptibility, CAL formation, or IVIG resistance. FcγRIIA mRNA expression levels were significantly higher in IVIG-resistant patients than in those that responded to IVIG during the pre-treatment period. Furthermore, the FcγRIIA/IIB mRNA expression ratio was considerably higher in KD patients with CAL than in those without CAL. FcγRIIA and FcγRIIB both demonstrated increased methylation levels in KD patients that underwent IVIG treatment. FcγRIIA expression influenced the IVIG treatment response of KD patients. The FcγRIIA/IIB mRNA expression ratio was greater in KD patients with CAL formation. PMID:27893416

  5. Short- and long-term variations in non-linear dynamics of heart rate variability

    DEFF Research Database (Denmark)

    Kanters, J K; Højgaard, M V; Agner, E

    1996-01-01

    OBJECTIVES: The purpose of the study was to investigate the short- and long-term variations in the non-linear dynamics of heart rate variability, and to determine the relationships between conventional time and frequency domain methods and the newer non-linear methods of characterizing heart rate...... rate and describes mainly linear correlations. Non-linear predictability is correlated with heart rate variability measured as the standard deviation of the R-R intervals and the respiratory activity expressed as power of the high-frequency band. The dynamics of heart rate variability changes suddenly...

  6. Heart rate detection from an electronic weighing scale

    International Nuclear Information System (INIS)

    González-Landaeta, R; Casas, O; Pallàs-Areny, R

    2008-01-01

    We propose a novel technique for beat-to-beat heart rate detection based on the ballistocardiographic (BCG) force signal from a subject standing on a common electronic weighing scale. The detection relies on sensing force variations related to the blood acceleration in the aorta, works even if wearing footwear and does not require any sensors attached to the body because it uses the load cells in the scale. We have devised an approach to estimate the sensitivity and frequency response of three commercial weighing scales to assess their capability to detect the BCG force signal. Static sensitivities ranged from 490 nV V −1 N −1 to 1670 nV V −1 N −1 . The frequency response depended on the subject's mass but it was broad enough for heart rate estimation. We have designed an electronic pulse detection system based on off-the-shelf integrated circuits to sense heart-beat-related force variations of about 0.24 N. The signal-to-noise ratio of the main peaks of the force signal detected was higher than 30 dB. A Bland–Altman plot was used to compare the RR time intervals estimated from the ECG and BCG force signals for 17 volunteers. The error was ±21 ms, which makes the proposed technique suitable for short-term monitoring of the heart rate

  7. Guided imagery, anxiety, heart rate, and heart rate variability during centrifuge training.

    Science.gov (United States)

    Jing, Xiaolu; Wu, Ping; Liu, Fang; Wu, Bin; Miao, Danmin

    2011-02-01

    Centrifuge training is an important method of improving the hypergravity tolerance of pilots, cosmonauts, and Chinese astronauts. However, the concomitants of tension or anxiety often impede training. Guided imagery (GI), a mind-body relaxation technique, provides a behavioral and cognitive means whereby individuals are able to exert control over the focus of attention. This study aims to investigate the immediate effects of GI for reducing stress in centrifuge training. There were 12 healthy young men who were randomly assigned to a GI group or music group. We measured changes in heart rate during centrifuge training, in heart rate variability before and after centrifuge training, and also evaluated relaxation and anxiety in three phases: before intervention, after intervention, and following centrifuge training. The change in the pattern of anxiety was different in the two groups over the three phases. Anxiety (measured by State Anxiety Inventory) in the GI group changed from 31.7 +/- 5.9 to 26.8 +/- 2.6 and 27.8 +/- 4.1, whereas for the music group this changed from 32.2 +/- 7.6 to 31.2 +/- 8.3 and 26.8 +/- 6.8. During centrifuge training, the maximal HR for the GI group (101.2 +/- 8.8) was lower than that of the music group (123.0 +/- 19.1). In addition GI showed a decrease in low frequency (LF, 0.04-0.15 Hz) components and an increase in high frequency (HF, 0.15-0.4 Hz) components before and after centrifuge training. GI was capable of decreasing tension, anxiety, and sympathetic nervous system activity pre- or post-centrifugation.

  8. Resonance of about-weekly human heart rate rhythm with solar activity change.

    Science.gov (United States)

    Cornelissen, G; Halberg, F; Wendt, H W; Bingham, C; Sothern, R B; Haus, E; Kleitman, E; Kleitman, N; Revilla, M A; Revilla, M; Breus, T K; Pimenov, K; Grigoriev, A E; Mitish, M D; Yatsyk, G V; Syutkina, E V

    1996-12-01

    In several human adults, certain solar activity rhythms may influence an about 7-day rhythm in heart rate. When no about-weekly feature was found in the rate of change in sunspot area, a measure of solar activity, the double amplitude of a circadian heart rate rhythm, approximated by the fit of a 7-day cosine curve, was lower, as was heart rate corresponds to about-weekly features in solar activity and/or relates to a sunspot cycle.

  9. Separating the effect of respiration from the heart rate variability for cases of constant harmonic breathing

    Directory of Open Access Journals (Sweden)

    Kircher Michael

    2015-09-01

    Full Text Available Heart Rate Variability studies are a known measure for the autonomous control of the heart rate. In special situations, its interpretation can be ambiguous, since the respiration has a major influence on the heart rate variability. For this reason it has often been proposed to measure Heart Rate Variability, while the subjects are breathing at a constant respiration rate. That way the spectral influence of the respiration is known. In this work we propose to remove this constant respiratory influence from the heart rate and the Heart Rate Variability parameters to gain respiration free autonomous controlled heart rate signal. The spectral respiratory component in the heart rate signal is detected and characterized. Subsequently the respiratory effect on Heart Rate Variability is removed using spectral filtering approaches, such as the Notch filter or the Raised Cosine filter. As a result new decoupled Heart Variability parameters are gained, which could lead to new additional interpretations of the autonomous control of the heart rate.

  10. Functionality of the baroreceptor nerves in heart rate regulation

    DEFF Research Database (Denmark)

    Ottesen, Johnny T.; Olufsen, Mette

    2011-01-01

    are a consequence of the memory encapsulated by the models, and the nonlinearity gives rise to sigmoidal response curves. The nonlinear afferent baroreceptor models are coupled with an effector model, and the coupled model has been used to predict baroreceptor feedback regulation of heart rate during postural...... change from sitting to standing and during head-up tilt. The efferent model couples the afferent nerve paths to the sympathetic and parasympathetic outflow, and subsequently predicts the build up of an action potential at the sinus knot of the heart. In this paper, we analyze the nonlinear afferent model...... and show that the coupled model is able to predict heart rate regulation using blood pressure data as an input...

  11. New descriptors of T-wave morphology are independent of heart rate

    DEFF Research Database (Denmark)

    Andersen, Mads Peter; Xue, Joel Q; Graff, Claus

    2008-01-01

    from daytime Holter recordings. Duration parameters (QT, ToTe, TpTe, and others), a number of basic T-wave morphology parameters (amplitude, area, and others) as well as advanced morphology descriptors (asymmetry, flatness, and others) were measured automatically. Heart rate dependence was examined...... by means of analysis of covariance. The results showed clear heart rate dependence for the QT interval (R(2) = 0.53-0.57) and a moderate degree of heart rate dependence for the basic morphology parameters (amplitude, area, and others) (R(2) = 0.17-0.42). Both the advanced T-wave descriptors (asymmetry......T-wave morphology descriptors are sensitive to drug-induced changes and may be a useful addition to the QT interval in cardiac safety trials. Intrasubject heart rate dependence of T-wave morphology was investigated in a sample of 39 healthy individuals. Ten-second electrocardiograms were obtained...

  12. Discussion on the tropospheric concentrations of FC21

    Energy Technology Data Exchange (ETDEWEB)

    Crescentini, G.; Mangani, F.; Mastrogiamcomo, A.R.; Cappiello, A.; Bruner, F.

    1986-01-01

    FC21 tropospheric mixing ratios measured in air samples collected at different locations in the world are presented. Results of a campaign carried out at two locations in the Sahara desert where FC21 and FC11 mixing ratios were simultaneously determined in 180 samples are also shown. Though scattered high values have been found, the average background concentration of FC21 ranged between 0 and 1 pptv. 9 references, 1 figure, 2 tables.

  13. Unconstrained monitoring of long-term heart and breath rates during sleep

    International Nuclear Information System (INIS)

    Chen, Wenxi; Zhu, Xin; Wei, Daming; Nemoto, Tetsu; Sugitani, Kayo; Kitamura, Kei-ichiro

    2008-01-01

    An unconstrained method for the long-term monitoring of heart and breath rates during sleep is proposed. The system includes a sensor unit and a web-based network module. The sensor unit is set beneath a pillow to pick up the pressure variations from the head induced by inhalation/exhalation movements and heart pulsation during sleep. The measured pressure signal was digitized and transferred to a remote database server via the network module. A wavelet-based algorithm was employed to detect the heart and breath rates, as well as body movement, during sleep. The overall system was utilized for a total six-month trial operation delivered to a female subject. The profiles of the heart and breath rates on a beat-by-beat and daily basis were obtained. Movements during sleep were also estimated. The results show that the daily average percentage of undetectable periods (UPs) during 881.6 sleep hours over a 180 day period was 17.2%. A total of 89.2% of sleep hours had a UP of not more than 25%. The profile of the heart rate revealed a periodic property that corresponded to the female monthly menstrual cycle. Our system shows promise as a long-term unconstrained monitor for heart and breath rates, and for other physiological parameters related to the quality of sleep and the regularity of the menstrual cycle. (note)

  14. Aggressive behavior: an alternative model of resting heart rate and sensation seeking.

    Science.gov (United States)

    Wilson, Laura C; Scarpa, Angela

    2014-01-01

    Low resting heart rate is a well-replicated biological correlate of aggression, and sensation seeking is frequently cited as the underlying causal explanation. However, little empirical evidence supports this mediating relationship. Furthermore, the biosocial model of violence and social push theory suggest sensation seeking may moderate the relationship between heart rate and aggression. In a sample of 128 college students (82.0% White; 73.4% female), the current study tested a moderation model as an alternative relationship between resting heart rate and sensation seeking in regard to aggression. Overall, the findings partially supported an interaction effect, whereby the relationship between heart rate and aggression was moderated by sensation seeking. Specifically, the oft-noted relationship between low resting heart rate and increased aggression was found, but only for individuals with low levels of sensation seeking. If replication supports this finding, the results may better inform prevention and intervention work. © 2013 Wiley Periodicals, Inc.

  15. Heart Rate and Increased Intravascular Volume

    Czech Academy of Sciences Publication Activity Database

    Souček, M.; Kára, T.; Jurák, Pavel; Halámek, Josef; Špinarová, L.; Meluzín, J.; Toman, J.; Řiháček, I.; Šumbera, J.; Fráňa, P.

    2003-01-01

    Roč. 52, - (2003), s. 137 - 140 ISSN 0862-8408 R&D Projects: GA ČR GA102/02/1339 Institutional research plan: CEZ:AV0Z2065902 Keywords : kidneys * heart rate * atrial mechanisms Subject RIV: FA - Cardiovascular Diseases incl. Cardiotharic Surgery Impact factor: 0.939, year: 2003

  16. Traces of pFc' in IVIG interact with human IgG Fc domains and counteract aggregation

    NARCIS (Netherlands)

    Rispens, Theo; Himly, Martin; Ooievaar-de Heer, Pleuni; den Bleker, Tamara H.; Aalberse, Rob C.

    2010-01-01

    To prevent multimer formation, intravenous immunoglobulin (IVIG) is often treated with traces of pepsin. So far, the mechanism behind this treatment has been unclear. Recently, we reported that human IgG4 binds other IgG molecules via Fc-Fc interactions. Here we show that IVIG treated with traces of

  17. Triboelectric Nanogenerator Enabled Body Sensor Network for Self-Powered Human Heart-Rate Monitoring.

    Science.gov (United States)

    Lin, Zhiming; Chen, Jun; Li, Xiaoshi; Zhou, Zhihao; Meng, Keyu; Wei, Wei; Yang, Jin; Wang, Zhong Lin

    2017-09-26

    Heart-rate monitoring plays a critical role in personal healthcare management. A low-cost, noninvasive, and user-friendly heart-rate monitoring system is highly desirable. Here, a self-powered wireless body sensor network (BSN) system is developed for heart-rate monitoring via integration of a downy-structure-based triboelectric nanogenerator (D-TENG), a power management circuit, a heart-rate sensor, a signal processing unit, and Bluetooth module for wireless data transmission. By converting the inertia energy of human walking into electric power, a maximum power of 2.28 mW with total conversion efficiency of 57.9% was delivered at low operation frequency, which is capable of immediately and sustainably driving the highly integrated BSN system. The acquired heart-rate signal by the sensor would be processed in the signal process circuit, sent to an external device via the Bluetooth module, and displayed on a personal cell phone in a real-time manner. Moreover, by combining a TENG-based generator and a TENG-based sensor, an all-TENG-based wireless BSN system was developed, realizing continuous and self-powered heart-rate monitoring. This work presents a potential method for personal heart-rate monitoring, featured as being self-powered, cost-effective, noninvasive, and user-friendly.

  18. Relationships between heart rate and age, bodyweight and breed in 10,849 dogs.

    Science.gov (United States)

    Hezzell, M J; Dennis, S G; Humm, K; Agee, L; Boswood, A

    2013-06-01

    To evaluate relationships between heart rate and clinical variables in healthy dogs and dogs examined at a referral hospital. Clinical data were extracted from the electronic patient records of a first opinion group (5000 healthy dogs) and a referral hospital (5849 dogs). Univariable and multi-variable general linear models were used to assess associations between heart rate and clinical characteristics. Separate multi-variable models were constructed for first opinion and referral populations. In healthy dogs, heart rate was negatively associated with bodyweight (PChihuahuas. The mean difference in heart rate between a 5 and 55 kg dog was 10.5 beats per minute. In dogs presenting to a referral hospital, heart rate was negatively associated with bodyweight (P<0.001) and the following breeds; border collie, golden retriever, Labrador retriever, springer spaniel and West Highland white terrier and positively associated with age, admitting service (emergency and critical care, emergency first opinion and cardiology) and the following breeds; Cavalier King Charles spaniel, Staffordshire bull terrier and Yorkshire terrier. Bodyweight, age, breed and disease status all influence heart rate in dogs, although these factors account for a relatively small proportion of the overall variability in heart rate. © 2013 British Small Animal Veterinary Association.

  19. Influence of different characteristics of sport on heart rate recovery in elite athletes

    Directory of Open Access Journals (Sweden)

    Anđić Radovan

    2016-01-01

    Full Text Available Introduction: One of the benefits of regular physical activity is lower resting heart rate and its faster recovery after maximal exercise test, as a result of a stronger parasympatic (vagal tone. Heart rate recovery is used as reliable parameter for prescription of the training program and also in prognostic purposes as a parameter of risk for developing cardiovascular diseases. Aim: The purpose of this study is to show significant differences in heart rate recovery after maximal exercise test and resting heart rate among different groups of elite athletes. Material and Methods: This study subjected 575 adult (23.1 ± 4.3 years, male athletes divided into four sport groups: skill, power, mixed and endurance. Every subject performed progressive, maximal cardiopulmonary exercise test on a treadmill. Heart rate recovery in first (ΔHRR1 and third (ΔHRR3 minute was calculated as a difference of maximal heart rate and heart rate in the first and the third minute after cessation of exercise, respectively. Results: Compared to skill, power and mixed group (62.9 ± 11.4; 61.5 ± 10.0; 59.9 ± 10.4 min-1 respectively, significantly lower values od resting heart rate are recorded in the endurance group (56.2 ± 10.6 min-1 (p = 0,05. Also, ΔHRR1 was significantly higher in the endurance group (33.5 ±14.3 min-1 compared to skill, power and mixed group (24.3 ± 10.9; 25.5 ± 11.2; 27.8 ± 15.6 min-1 respectively (p = 0,05. Values od ΔHRR3 were significantly higher in power, mixed and endurance groups (74.8 ± 14.3; 79.5 ± 12.7; 79.4 ± 12.6 min-1 respectively compared to skill group (67.3±16.1 min-1 (p = 0,05. Conclusion: Training endurance group of sports has the most contribution to lower resting heart rate and faster recovery of heart rate in the first minute after exercising, due to dominant parasympatic tone.

  20. QRS peak detection for heart rate monitoring on Android smartphone

    Science.gov (United States)

    Pambudi Utomo, Trio; Nuryani, Nuryani; Darmanto

    2017-11-01

    In this study, Android smartphone is used for heart rate monitoring and displaying electrocardiogram (ECG) graph. Heart rate determination is based on QRS peak detection. Two methods are studied to detect the QRS complex peak; they are Peak Threshold and Peak Filter. The acquisition of ECG data is utilized by AD8232 module from Analog Devices, three electrodes, and Microcontroller Arduino UNO R3. To record the ECG data from a patient, three electrodes are attached to particular body’s surface of a patient. Patient’s heart activity which is recorded by AD8232 module is decoded by Arduino UNO R3 into analog data. Then, the analog data is converted into a voltage value (mV) and is processed to get the QRS complex peak. Heart rate value is calculated by Microcontroller Arduino UNO R3 uses the QRS complex peak. Voltage, heart rate, and the QRS complex peak are sent to Android smartphone by Bluetooth HC-05. ECG data is displayed as the graph by Android smartphone. To evaluate the performance of QRS complex peak detection method, three parameters are used; they are positive predictive, accuracy and sensitivity. Positive predictive, accuracy, and sensitivity of Peak Threshold method is 92.39%, 70.30%, 74.62% and for Peak Filter method are 98.38%, 82.47%, 83.61%, respectively.

  1. Heart rate effects of intraosseous injections using slow and fast rates of anesthetic solution deposition.

    Science.gov (United States)

    Susi, Louis; Reader, Al; Nusstein, John; Beck, Mike; Weaver, Joel; Drum, Melissa

    2008-01-01

    The authors, using a crossover design, randomly administered, in a single-blind manner, 3 primary intraosseous injections to 61 subjects using: the Wand local anesthetic system at a deposition rate of 45 seconds (fast injection); the Wand local anesthetic system at a deposition rate of 4 minutes and 45 seconds (slow injection); a conventional syringe injection at a deposition rate of 4 minutes and 45 seconds (slow injection), in 3 separate appointments spaced at least 3 weeks apart. A pulse oximeter measured heart rate (pulse). The results demonstrated the mean maximum heart rate was statistically higher with the fast intraosseous injection (average 21 to 28 beats/min increase) than either of the 2 slow intraosseous injections (average 10 to 12 beats/min increase). There was no statistically significant difference between the 2 slow injections. We concluded that an intraosseous injection of 1.4 mL of 2% lidocaine with 1 : 100,000 epinephrine with the Wand at a 45-second rate of anesthetic deposition resulted in a significantly higher heart rate when compared with a 4-minute and 45-second anesthetic solution deposition using either the Wand or traditional syringe.

  2. Value of Serial Heart Rate Variability Measurement for Prediction of Appropriate ICD Discharge in Patients with Heart Failure

    NARCIS (Netherlands)

    ten Sande, Judith N.; Damman, Peter; Tijssen, Jan G. P.; de Groot, Joris R.; Knops, Reinoud E.; Wilde, Arthur A. M.; van Dessel, Pascal F. H. M.

    2014-01-01

    HRV and Appropriate ICD Shock in Heart Failure Introduction Decreased heart rate variability (HRV) is associated with adverse outcomes in patients with heart failure. Our objective was to examine whether decreased HRV predicts appropriate implantable cardioverter defibrillator (ICD) shocks. Methods

  3. Smart pillow for heart-rate monitoring using a fiber optic sensor

    Science.gov (United States)

    Chen, Zhihao; Teo, Ju Teng; Ng, Soon Huat; Yim, Huiqing

    2011-03-01

    In this paper, we propose and demonstrate a new method to monitor heart rate using fiber optic microbending based sensor for in-bed non-intrusive monitoring. The sensing system consists of transmitter, receiver, sensor mat, National Instrument (NI) data acquisition (DAQ) card and a computer for signal processing. The sensor mat is embedded inside a commercial pillow. The heart rate measurement system shows an accuracy of +/-2 beats, which has been successfully demonstrated in a field trial. The key technological advantage of our system is its ability to measure heart rate with no preparation and minimal compliance by the patient.

  4. QT measurement and heart rate correction during hypoglycemia

    DEFF Research Database (Denmark)

    Christensen, Toke Folke; Randløv, Jette; Christensen, Leif Engmann

    2010-01-01

    induced by intravenous injection of two insulin types in a cross-over design. QT measurements were done using the slope-intersect (SI) and manual annotation (MA) methods. Heart rate correction was done using Bazett's (QTcB) and Fridericia's (QTcF) formulas. Results. The SI method showed significant......Introduction. Several studies show that hypoglycemia causes QT interval prolongation. The aim of this study was to investigate the effect of QT measurement methodology, heart rate correction, and insulin types during hypoglycemia. Methods. Ten adult subjects with type 1 diabetes had hypoglycemia...... prolongation at hypoglycemia for QTcB (42(6) ms; P measuring the QT interval has...

  5. Age-related disappearance of Mayer-like heart rate waves

    Science.gov (United States)

    Jarisch, W. R.; Ferguson, J. J.; Shannon, R. P.; Wei, J. Y.; Goldberger, A. L.

    1987-01-01

    The effect of age on the principal spectral components of heart rate obtained immediately after passive upright tilt was investigated in human subjects who underwent a 60-deg tilt over 9 sec. Two groups were examined, the first of which consisting of healthy male subjects aged 22-26 years, while the second was comprised of subjects aged 65-84 years on no medication; radiograms were recorded continuously beginning just prior to tilt until 3 min posttilt. The results of spectral analysis showed that elderly subjects did not exhibit the Mayer-like heart rate waves (the 0.07-0.09 Hz oscillations) that were present in the spectra of young subjects immediately after passive upright tilt. The findings are consistent with the concept of a 'dysautonomia of aging'. It is suggested that postural stress testing with spectral analysis of heart rate fluctuations may provide a useful way of assessing physiologic vs chronologic age.

  6. Estimating energy expenditure from heart rate in older adults: a case for calibration.

    Science.gov (United States)

    Schrack, Jennifer A; Zipunnikov, Vadim; Goldsmith, Jeff; Bandeen-Roche, Karen; Crainiceanu, Ciprian M; Ferrucci, Luigi

    2014-01-01

    Accurate measurement of free-living energy expenditure is vital to understanding changes in energy metabolism with aging. The efficacy of heart rate as a surrogate for energy expenditure is rooted in the assumption of a linear function between heart rate and energy expenditure, but its validity and reliability in older adults remains unclear. To assess the validity and reliability of the linear function between heart rate and energy expenditure in older adults using different levels of calibration. Heart rate and energy expenditure were assessed across five levels of exertion in 290 adults participating in the Baltimore Longitudinal Study of Aging. Correlation and random effects regression analyses assessed the linearity of the relationship between heart rate and energy expenditure and cross-validation models assessed predictive performance. Heart rate and energy expenditure were highly correlated (r=0.98) and linear regardless of age or sex. Intra-person variability was low but inter-person variability was high, with substantial heterogeneity of the random intercept (s.d. =0.372) despite similar slopes. Cross-validation models indicated individual calibration data substantially improves accuracy predictions of energy expenditure from heart rate, reducing the potential for considerable measurement bias. Although using five calibration measures provided the greatest reduction in the standard deviation of prediction errors (1.08 kcals/min), substantial improvement was also noted with two (0.75 kcals/min). These findings indicate standard regression equations may be used to make population-level inferences when estimating energy expenditure from heart rate in older adults but caution should be exercised when making inferences at the individual level without proper calibration.

  7. Resemblances of Parents and Twins in Sport Participation and Heart Rate

    NARCIS (Netherlands)

    Boomsma, D.I.; van den Bree, M.B.; Orlebeke, J.F.; Molenaar, P.C.M.

    1989-01-01

    A model to analyze resemblances of twins and parents using LISREL is outlined and applied to sports participation and heart-rate data. Sports participation and heart rate were measured in 44 monozygotic and 46 dizygotic adolescent twin pairs and in their parents. Genetic factors influence variation

  8. Gaussian Mixture Model of Heart Rate Variability

    Science.gov (United States)

    Costa, Tommaso; Boccignone, Giuseppe; Ferraro, Mario

    2012-01-01

    Heart rate variability (HRV) is an important measure of sympathetic and parasympathetic functions of the autonomic nervous system and a key indicator of cardiovascular condition. This paper proposes a novel method to investigate HRV, namely by modelling it as a linear combination of Gaussians. Results show that three Gaussians are enough to describe the stationary statistics of heart variability and to provide a straightforward interpretation of the HRV power spectrum. Comparisons have been made also with synthetic data generated from different physiologically based models showing the plausibility of the Gaussian mixture parameters. PMID:22666386

  9. Adaptive Mean and Trend Removal of Heart Rate Variability Using Kalman Filtering

    National Research Council Canada - National Science Library

    Schloegl, A

    2001-01-01

    Analysis of heart rate van ability requires the calculation of the mean heart rate, Adaptive methods are important for online and real-time parameter estimation, In this paper we demonstrate the use...

  10. Heart rate variability in patients with systemic lupus erythematosus: a systematic review and methodological considerations.

    Science.gov (United States)

    Matusik, P S; Matusik, P T; Stein, P K

    2018-07-01

    Aim The aim of this review was to summarize current knowledge about the scientific findings and potential clinical utility of heart rate variability measures in patients with systemic lupus erythematosus. Methods PubMed, Embase and Scopus databases were searched for the terms associated with systemic lupus erythematosus and heart rate variability, including controlled vocabulary, when appropriate. Articles published in English and available in full text were considered. Finally, 11 publications were selected, according to the systematic review protocol and were analyzed. Results In general, heart rate variability, measured in the time and frequency domains, was reported to be decreased in patients with systemic lupus erythematosus compared with controls. In some systemic lupus erythematosus studies, heart rate variability was found to correlate with inflammatory markers and albumin levels. A novel heart rate variability measure, heart rate turbulence onset, was shown to be increased, while heart rate turbulence slope was decreased in systemic lupus erythematosus patients. Reports of associations of changes in heart rate variability parameters with increasing systemic lupus erythematosus activity were inconsistent, showing decreasing heart rate variability or no relationship. However, the low/high frequency ratio was, in some studies, reported to increase with increasing disease activity or to be inversely correlated with albumin levels. Conclusions Patients with systemic lupus erythematosus have abnormal heart rate variability, which reflects cardiac autonomic dysfunction and may be related to inflammatory cytokines but not necessarily to disease activity. Thus measurement of heart rate variability could be a useful clinical tool for monitoring autonomic dysfunction in systemic lupus erythematosus, and may potentially provide prognostic information.

  11. iHeartrate: a heart rate controlled in-flight music recommendation system

    NARCIS (Netherlands)

    Liu, H.; Hu, J.; Rauterberg, G.W.M.; Spink, A.J.; Grieco, O.E.; Krips, L.W.S.; Loijens, L.P.J.J.; Noldus, xx; Zimmerman, P.H.

    2010-01-01

    Travel by air, especially long distance, the enclosed environment of the aircraft cabin causes discomfort and even stress to flight passengers. In this paper, we present a new heart rate controlled music recommendation system. Heart rate is used as a stress indicator. If the user is stressed and

  12. Identification of heart rate-associated loci and their effects on cardiac conduction and rhythm disorders

    DEFF Research Database (Denmark)

    den Hoed, Marcel; Eijgelsheim, Mark; Esko, Tõnu

    2013-01-01

    of dilated cardiomyopathy, congenital heart failure and/or sudden cardiac death. In addition, genetic susceptibility to increased heart rate is associated with altered cardiac conduction and reduced risk of sick sinus syndrome, and both heart rate-increasing and heart rate-decreasing variants associate...

  13. Gender differences of heart rate variability in healthy volunteers

    International Nuclear Information System (INIS)

    Saleem, S.; Majeed, S.M.I.; Khan, M.A.

    2012-01-01

    Objective: To identify the basic values of heart rate variability in Pakistani population and to verify our hypothesis that there are gender differences in cardiovascular autonomic modulation. Methods: The descriptive cross sectional study based on convenience probability sampling was conducted at Armed Forces Institute of Cardiology/National Institute of Heart Diseases (AFIC/NIHD) Pakistan. The duration of the study was from December 2009 to July 2010. It involved 24-hour holter monitoring of 45 healthy individuals using holter electrocardiography (ECG) recorder. Heart rate variability was analysed in time (SDNN, SDANN, SDNNi, rMSSD, pNN50) and frequency domains (power, VLF, LF, and HF). Results: The time domain indices; SDNN (male=140 +- 36 ms vs. females=122 +- 33 ms; p =0.09), SDANN (male=123 +- 34 ms vs. females=111+- 34 ms; P= 0.23), SDNNi (male=64 +-19 ms vs. females=52 +- 14 ms; P= 0.03), and pNN50 (male=14 +- 10 ms vs. females=12 +- 7 ms; P= 0.43) were decreased in female volunteers when compared with males. Comparison of frequency domain indices; Total power (male=4041 +- 3150 ms/sup 2/ vs. females=2750 +- 1439 ms/sup 2/; P= 0.07), VLF (male=291 2675 ms/sup 2/ vs. females=1843 +- 928 ms/sup 2/; P= 0.06), LF (male=788 +- 397 ms/sup 2/ vs. females=556 +- 346 ms/sup 2/; P= 0.04) and HF (male=318 +- 251 ms/sup 2/ vs. females=31 277 ms/sup 2/; P= 0.94) amongst males and females showed attenuated heart rate variability in females. Of all the observed values, SDNNi and LF were found significantly (p <0.05) decreased in women. Conclusion: In healthy population, heart rate variability is low in women than men. It reflects sympathetic dominance in women in our population. (author)

  14. Heart rate variability as determinism with jump stochastic parameters.

    Science.gov (United States)

    Zheng, Jiongxuan; Skufca, Joseph D; Bollt, Erik M

    2013-08-01

    We use measured heart rate information (RR intervals) to develop a one-dimensional nonlinear map that describes short term deterministic behavior in the data. Our study suggests that there is a stochastic parameter with persistence which causes the heart rate and rhythm system to wander about a bifurcation point. We propose a modified circle map with a jump process noise term as a model which can qualitatively capture such this behavior of low dimensional transient determinism with occasional (stochastically defined) jumps from one deterministic system to another within a one parameter family of deterministic systems.

  15. Change of Diurnal Heart Rate Patterns During Pregnancy and Lactation in Dogs (Canis familiaris

    Directory of Open Access Journals (Sweden)

    Häggström J

    2003-09-01

    Full Text Available Pregnancy and lactation involve great demands on the cardiovascular system. The purpose of this study was to investigate how the heart rate and diurnal heart rate pattern change when dogs become pregnant or lactate. Five clinically healthy female beagle dogs were mated, and delivered three to seven healthy puppies. The heart rate was investigated with 24-h ECG (Holter once during anoestrus, at 3, 5, 7 and 9 weeks of pregnancy, and at week 4 postpartum (lactation. However, at 9 weeks, the ECG could not be recorded for the fully 24 h in 4 of 5 dogs, because labour started and the dogs then appeared disturbed by the recordings. The results at this date are not included in the statistical comparison. The heart rate increased progressively during pregnancy and was still elevated at 4 weeks of lactation. During late pregnancy the difference in heart rates between daytime and nighttime became smaller, but the heart rate was significantly higher in daytime in all periods. In conclusion, the increased heart rates during pregnancy and lactation reflect increased demands on the cardiovascular system and may be important to consider in clinical practice.

  16. Analysis of the Effects of the Bruton's tyrosine kinase (Btk) Inhibitor Ibrutinib on Monocyte Fcγ Receptor (FcγR) Function.

    Science.gov (United States)

    Ren, Li; Campbell, Amanda; Fang, Huiqing; Gautam, Shalini; Elavazhagan, Saranya; Fatehchand, Kavin; Mehta, Payal; Stiff, Andrew; Reader, Brenda F; Mo, Xiaokui; Byrd, John C; Carson, William E; Butchar, Jonathan P; Tridandapani, Susheela

    2016-02-05

    The irreversible Bruton's tyrosine kinase (Btk) inhibitor ibrutinib has shown efficacy against B-cell tumors such as chronic lymphocytic leukemia and B-cell non-Hodgkin lymphoma. Fcγ receptors (FcγR) on immune cells such as macrophages play an important role in tumor-specific antibody-mediated immune responses, but many such responses involve Btk. Here we tested the effects of ibrutinib on FcγR-mediated activities in monocytes. We found that ibrutinib did not affect monocyte FcγR-mediated phagocytosis, even at concentrations higher than those achieved physiologically, but suppressed FcγR-mediated cytokine production. We confirmed these findings in macrophages from Xid mice in which Btk signaling is defective. Because calcium flux is a major event downstream of Btk, we tested whether it was involved in phagocytosis. The results showed that blocking intracellular calcium flux decreased FcγR-mediated cytokine production but not phagocytosis. To verify this, we measured activation of the GTPase Rac, which is responsible for actin polymerization. Results showed that ibrutinib did not inhibit Rac activation, nor did the calcium chelator 1,2-bis(2-aminophenoxy)ethane-N,N,N',N'-tetraacetic acid tetrakis(acetoxymethyl ester). We next asked whether the effect of ibrutinib on monocyte FcγR-mediated cytokine production could be rescued by IFNγ priming because NK cells produce IFNγ in response to antibody therapy. Pretreatment of monocytes with IFNγ abrogated the effects of ibrutinib on FcγR-mediated cytokine production, suggesting that IFNγ priming could overcome this Btk inhibition. Furthermore, in monocyte-natural killer cell co-cultures, ibrutinib did not inhibit FcγR-mediated cytokine production despite doing so in single cultures. These results suggest that combining ibrutinib with monoclonal antibody therapy could enhance chronic lymphocytic leukemia cell killing without affecting macrophage effector function. © 2016 by The American Society for Biochemistry

  17. Analysis of the Effects of the Bruton's tyrosine kinase (Btk) Inhibitor Ibrutinib on Monocyte Fcγ Receptor (FcγR) Function*

    Science.gov (United States)

    Ren, Li; Campbell, Amanda; Fang, Huiqing; Gautam, Shalini; Elavazhagan, Saranya; Fatehchand, Kavin; Mehta, Payal; Stiff, Andrew; Reader, Brenda F.; Mo, Xiaokui; Byrd, John C.; Carson, William E.; Butchar, Jonathan P.; Tridandapani, Susheela

    2016-01-01

    The irreversible Bruton's tyrosine kinase (Btk) inhibitor ibrutinib has shown efficacy against B-cell tumors such as chronic lymphocytic leukemia and B-cell non-Hodgkin lymphoma. Fcγ receptors (FcγR) on immune cells such as macrophages play an important role in tumor-specific antibody-mediated immune responses, but many such responses involve Btk. Here we tested the effects of ibrutinib on FcγR-mediated activities in monocytes. We found that ibrutinib did not affect monocyte FcγR-mediated phagocytosis, even at concentrations higher than those achieved physiologically, but suppressed FcγR-mediated cytokine production. We confirmed these findings in macrophages from Xid mice in which Btk signaling is defective. Because calcium flux is a major event downstream of Btk, we tested whether it was involved in phagocytosis. The results showed that blocking intracellular calcium flux decreased FcγR-mediated cytokine production but not phagocytosis. To verify this, we measured activation of the GTPase Rac, which is responsible for actin polymerization. Results showed that ibrutinib did not inhibit Rac activation, nor did the calcium chelator 1,2-bis(2-aminophenoxy)ethane-N,N,N′,N′-tetraacetic acid tetrakis(acetoxymethyl ester). We next asked whether the effect of ibrutinib on monocyte FcγR-mediated cytokine production could be rescued by IFNγ priming because NK cells produce IFNγ in response to antibody therapy. Pretreatment of monocytes with IFNγ abrogated the effects of ibrutinib on FcγR-mediated cytokine production, suggesting that IFNγ priming could overcome this Btk inhibition. Furthermore, in monocyte-natural killer cell co-cultures, ibrutinib did not inhibit FcγR-mediated cytokine production despite doing so in single cultures. These results suggest that combining ibrutinib with monoclonal antibody therapy could enhance chronic lymphocytic leukemia cell killing without affecting macrophage effector function. PMID:26627823

  18. Conventional heart rate variability analysis of ambulatory electrocardiographic recordings fails to predict imminent ventricular fibrillation

    Science.gov (United States)

    Vybiral, T.; Glaeser, D. H.; Goldberger, A. L.; Rigney, D. R.; Hess, K. R.; Mietus, J.; Skinner, J. E.; Francis, M.; Pratt, C. M.

    1993-01-01

    OBJECTIVES. The purpose of this report was to study heart rate variability in Holter recordings of patients who experienced ventricular fibrillation during the recording. BACKGROUND. Decreased heart rate variability is recognized as a long-term predictor of overall and arrhythmic death after myocardial infarction. It was therefore postulated that heart rate variability would be lowest when measured immediately before ventricular fibrillation. METHODS. Conventional indexes of heart rate variability were calculated from Holter recordings of 24 patients with structural heart disease who had ventricular fibrillation during monitoring. The control group consisted of 19 patients with coronary artery disease, of comparable age and left ventricular ejection fraction, who had nonsustained ventricular tachycardia but no ventricular fibrillation. RESULTS. Heart rate variability did not differ between the two groups, and no consistent trends in heart rate variability were observed before ventricular fibrillation occurred. CONCLUSIONS. Although conventional heart rate variability is an independent long-term predictor of adverse outcome after myocardial infarction, its clinical utility as a short-term predictor of life-threatening arrhythmias remains to be elucidated.

  19. Behaviour, heart rate, and heart rate variability in pigs exposed to novelty

    Directory of Open Access Journals (Sweden)

    Manja Zupan

    2016-03-01

    Full Text Available ABSTRACT In the present study, we investigated behavioural responses and determined parameters of heart rate variability (HRV to elucidate a relative activation of autonomic nervous system (ANS during baseline (10 min and in response to potentially stressful situations (10 min in two pig breeds and sexes. Gilts (n = 21 and barrows (n = 9 of the Landrace × Yorkshire (LY; n = 15 and Landrace/Yorkshire × Landrace/Duroc (LYLD; n = 15 breeds were subjected to a novel object test (NOT and a novel arena test (NAT. Basal ANS state differed in pigs across breeds but not sexes. Landrace × Yorkshire pigs had a significantly lower basal heart rate (HR and low-frequency band (LF with a higher root mean square of successive interbeat intervals (RMSSD and high-frequency band (HF than LYLD pigs. In the NOT, despite having similar cardiac responses, gilts had a longer duration of contact with a novel object, higher lying and standing duration, and a lower duration of walking compared with barrows. In the NAT, we found similar behaviour across sexes but a different degree of ANS state, with barrows having a significantly higher increase in LF/HF (power of the low frequency component divided by the power of the high-frequency band compared with gilts. Landrace/Yorkshire × Landrace/Duroc pigs showed longer duration of contact with a novel object in the NOT accompanied by less lying and standing than LY pigs in both tests. No difference in ANS activation between breeds was found in the NOT. In the NAT, HR increased more from baseline to testing in LY pigs than in LYLD pigs. There is a complex and often contradictory nature of relationships between behaviour and cardiac responses to novelty in pigs of different breeds and sexes.

  20. Effects of metronome breathing on the assessment of autonomic control using heart rate variability

    NARCIS (Netherlands)

    Haaksma, J; Brouwer, J; vandenBerg, MP; Dijk, WA; Dassen, WRM; Crijns, HJGM; Mulder, Lambertus; Mulder, Gysbertus

    1996-01-01

    Analysis of Heart Rate Variability is a non-invasive quantitative tool to study the influence of the autonomic nervous system on the heart. Rapid variations in heart rate, related to breathing are primarily mediated by the vagal limb of the autonomic nervous system. The resulting variations in heart

  1. Relationship between heart rate and quiescent interval of the cardiac cycle in children using MRI

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Wei [Texas Children' s Hospital, E. B. Singleton Department of Pediatric Radiology, Houston, TX (United States); Bogale, Saivivek [Baylor University Medical Center, Department of Radiology, Dallas, TX (United States); Golriz, Farahnaz [Baylor College of Medicine, Department of Radiology, Houston, TX (United States); Krishnamurthy, Rajesh [Nationwide Children' s Hospital, Department of Diagnostic Radiology, Columbus, OH (United States)

    2017-11-15

    Imaging the heart in children comes with the challenge of constant cardiac motion. A prospective electrocardiography-triggered CT scan allows for scanning during a predetermined phase of the cardiac cycle with least motion. This technique requires knowing the optimal quiescent intervals of cardiac cycles in a pediatric population. To evaluate high-temporal-resolution cine MRI of the heart in children to determine the relationship of heart rate to the optimal quiescent interval within the cardiac cycle. We included a total of 225 consecutive patients ages 0-18 years who had high-temporal-resolution cine steady-state free-precession sequence performed as part of a magnetic resonance imaging (MRI) or magnetic resonance angiography study of the heart. We determined the location and duration of the quiescent interval in systole and diastole for heart rates ranging 40-178 beats per minute (bpm). We performed the Wilcoxon signed rank test to compare the duration of quiescent interval in systole and diastole for each heart rate group. The duration of the quiescent interval at heart rates <80 bpm and >90 bpm was significantly longer in diastole and systole, respectively (P<.0001 for all ranges, except for 90-99 bpm [P=.02]). For heart rates 80-89 bpm, diastolic interval was longer than systolic interval, but the difference was not statistically significant (P=.06). We created a chart depicting optimal quiescent intervals across a range of heart rates that could be applied for prospective electrocardiography-triggered CT imaging of the heart. The optimal quiescent interval at heart rates <80 bpm is in diastole and at heart rates ≥90 bpm is in systole. The period of quiescence at heart rates 80-89 bpm is uniformly short in systole and diastole. (orig.)

  2. Small-volume amnioinfusion: a potential stimulus of intrapartum fetal heart rate accelerations.

    Science.gov (United States)

    Wax, Joseph R; Flaherty, Nina; Pinette, Michael G; Blackstone, Jacquelyn; Cartin, Angelina

    2004-02-01

    We describe a recurrent nonreassuring fetal heart rate pattern in which small-volume amnioinfusions apparently evoked fetal heart rate accelerations suggested fetal well-being, allowing that progressive labor that culminated in the vaginal delivery of a healthy infant.

  3. Aerobic exercise during pregnancy and presence of fetal-maternal heart rate synchronization.

    Directory of Open Access Journals (Sweden)

    Peter Van Leeuwen

    Full Text Available It has been shown that short-term direct interaction between maternal and fetal heart rates may take place and that this interaction is affected by the rate of maternal respiration. The aim of this study was to determine the effect of maternal aerobic exercise during pregnancy on the occurrence of fetal-maternal heart rate synchronization.In 40 pregnant women at the 36th week of gestation, 21 of whom exercised regularly, we acquired 18 min. RR interval time series obtained simultaneously in the mothers and their fetuses from magnetocardiographic recordings. The time series of the two groups were examined with respect to their heart rate variability, the maternal respiratory rate and the presence of synchronization epochs as determined on the basis of synchrograms. Surrogate data were used to assess whether the occurrence of synchronization was due to chance.In the original data, we found synchronization occurred less often in pregnancies in which the mothers had exercised regularly. These subjects also displayed higher combined fetal-maternal heart rate variability and lower maternal respiratory rates. Analysis of the surrogate data showed shorter epochs of synchronization and a lack of the phase coordination found between maternal and fetal beat timing in the original data.The results suggest that fetal-maternal heart rate coupling is present but generally weak. Maternal exercise has a damping effect on its occurrence, most likely due to an increase in beat-to-beat differences, higher vagal tone and slower breathing rates.

  4. Aerobic exercise during pregnancy and presence of fetal-maternal heart rate synchronization.

    Science.gov (United States)

    Van Leeuwen, Peter; Gustafson, Kathleen M; Cysarz, Dirk; Geue, Daniel; May, Linda E; Grönemeyer, Dietrich

    2014-01-01

    It has been shown that short-term direct interaction between maternal and fetal heart rates may take place and that this interaction is affected by the rate of maternal respiration. The aim of this study was to determine the effect of maternal aerobic exercise during pregnancy on the occurrence of fetal-maternal heart rate synchronization. In 40 pregnant women at the 36th week of gestation, 21 of whom exercised regularly, we acquired 18 min. RR interval time series obtained simultaneously in the mothers and their fetuses from magnetocardiographic recordings. The time series of the two groups were examined with respect to their heart rate variability, the maternal respiratory rate and the presence of synchronization epochs as determined on the basis of synchrograms. Surrogate data were used to assess whether the occurrence of synchronization was due to chance. In the original data, we found synchronization occurred less often in pregnancies in which the mothers had exercised regularly. These subjects also displayed higher combined fetal-maternal heart rate variability and lower maternal respiratory rates. Analysis of the surrogate data showed shorter epochs of synchronization and a lack of the phase coordination found between maternal and fetal beat timing in the original data. The results suggest that fetal-maternal heart rate coupling is present but generally weak. Maternal exercise has a damping effect on its occurrence, most likely due to an increase in beat-to-beat differences, higher vagal tone and slower breathing rates.

  5. Aerobic Exercise during Pregnancy and Presence of Fetal-Maternal Heart Rate Synchronization

    Science.gov (United States)

    Van Leeuwen, Peter; Gustafson, Kathleen M.; Cysarz, Dirk; Geue, Daniel; May, Linda E.; Grönemeyer, Dietrich

    2014-01-01

    It has been shown that short-term direct interaction between maternal and fetal heart rates may take place and that this interaction is affected by the rate of maternal respiration. The aim of this study was to determine the effect of maternal aerobic exercise during pregnancy on the occurrence of fetal-maternal heart rate synchronization. Methods In 40 pregnant women at the 36th week of gestation, 21 of whom exercised regularly, we acquired 18 min. RR interval time series obtained simultaneously in the mothers and their fetuses from magnetocardiographic recordings. The time series of the two groups were examined with respect to their heart rate variability, the maternal respiratory rate and the presence of synchronization epochs as determined on the basis of synchrograms. Surrogate data were used to assess whether the occurrence of synchronization was due to chance. Results In the original data, we found synchronization occurred less often in pregnancies in which the mothers had exercised regularly. These subjects also displayed higher combined fetal-maternal heart rate variability and lower maternal respiratory rates. Analysis of the surrogate data showed shorter epochs of synchronization and a lack of the phase coordination found between maternal and fetal beat timing in the original data. Conclusion The results suggest that fetal-maternal heart rate coupling is present but generally weak. Maternal exercise has a damping effect on its occurrence, most likely due to an increase in beat-to-beat differences, higher vagal tone and slower breathing rates. PMID:25162592

  6. Optimization on Fc for Improvement of Stability and Aggregation Resistance.

    Science.gov (United States)

    Chen, Xiaobo; Zeng, Fang; Huang, Tao; Cheng, Liang; Liu, Huan; Gong, Rui

    2016-01-01

    Fc-based therapeutics including therapeutic full-size monoclonal antibodies (mAbs) and Fcfusion proteins represent fastest-growing market in biopharmaceutical industrial. However, one major challenge during development of Fc-based therapeutics is how to maintain their efficacy in clinic use. Many factors may lead to failure in final marketing. For example, the stability and aggregation resistance might not be high enough for bearing the disadvantages during fermentation, purification, formulation, storage, shipment and other steps in manufacture and sale. Low stability and high aggregation tendency lead to decreased bioactivity and increased risk of immunogenicity resulting in serious side effect. Because Fc is one of the major parts in monoclonal antibodies and Fc-fusion proteins, engineering of Fc to increase its stability and reduce or eliminate aggregation due to incorrect association are of great importance and could further extend the potential of Fc-based therapeutics. Lots of studies focus on Fc optimization for better physical and chemical characteristics and function by structured-based computer-aid rational design, high-throughput screening expression system selection and other methods. The identification of optimized Fc mutants increases the clinic potential of currently existed therapeutics mAbs and Fc-fusion proteins, and accelerates the development of new Fc-based therapeutics. Here we provide an overview of the related field, and discuss recent advances and future directions in optimization of Fc-based therapeutics with modified stability and aggregation resistance. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  7. Heart Rate and Energy Expenditure in Division I Field Hockey Players During Competitive Play.

    Science.gov (United States)

    Sell, Katie M; Ledesma, Allison B

    2016-08-01

    Sell, KM and Ledesma, AB. Heart rate and energy expenditure in Division I field hockey players during competitive play. J Strength Cond Res 30(8): 2122-2128, 2016-The purpose of this study was to quantify energy expenditure and heart rate data for Division I female field hockey players during competitive play. Ten female Division I collegiate field hockey athletes (19.8 ± 1.6 years; 166.4 ± 6.1 cm; 58.2 ± 5.3 kg) completed the Yo-Yo intermittent endurance test to determine maximal heart rate. One week later, all subjects wore a heart rate monitor during a series of 3 matches in an off-season competition. Average heart rate (AvHR), average percentage of maximal heart rate (AvHR%), peak exercise heart rate (PExHR), and percentage of maximal heart rate (PExHR%), time spent in each of the predetermined heart rate zones, and caloric expenditure per minute of exercise (kcalM) were determined for all players. Differences between positions (backs, midfielders, and forwards) were assessed. No significant differences in AvHR, AvHR%, PExHR, PExHR%, and %TM were observed between playing positions. The AvHR% and PExHR% for each position fell into zones 4 (77-93% HRmax) and 5 (>93% HRmax), respectively, and significantly more time was spent in zone 4 compared with zones 1, 2, 3, and 5 across all players (p ≤ 0.05). The kcalM reflected very heavy intensity exercise. The results of this study will contribute toward understanding the sport-specific physiological demands of women's field hockey and has specific implications for the duration and schedule of training regimens.

  8. Bluetooth(Registered Trademark) Heart Rate Monitors for Spaceflight

    Science.gov (United States)

    Buxton, Roxanne E.; West, Michael R.; Kalogera, Kent L.; Hanson, Andrea M.

    2016-01-01

    Heart rate monitoring is required during exercise for crewmembers aboard the International Space Station (ISS) and will be for future exploration missions. The cardiovascular system must be sufficiently stressed throughout a mission to maintain the ability to perform nominal and contingency/emergency tasks. High quality heart rate data is required to accurately determine the intensity of exercise performed by the crewmembers and show maintenance of VO2max. The quality of the data collected on ISS is subject to multiple limitations and is insufficient to meet current requirements. PURPOSE: To evaluate the performance of commercially available Bluetooth® heart rate monitors (BT_HRM) and their ability to provide high quality heart rate data to monitor crew health on board ISS and during future exploration missions. METHODS: Nineteen subjects completed 30 data collection sessions of various intensities on the treadmill and/or cycle. Subjects wore several BT_HRM technologies for each testing session. One electrode-based chest strap (CS) was worn, while one or more optical sensors (OS) was worn. Subjects were instrumented with a 12-lead ECG to compare the heart rate data from the Bluetooth sensors. Each BT_RHM data set was time matched to the ECG data and a +/-5bpm threshold was applied to the difference between the two data sets. Percent error was calculated based on the number of data points outside the threshold and the total number of data points. REULTS: The electrode-based chest straps performed better than the optical sensors. The best performing CS was CS1 (1.6%error), followed by CS4 (3.3%error), CS3 (6.4%error), and CS2 (9.2%error). The OS resulted in 10.4% error for OS1 and 14.9% error for OS2. CONCLUSIONS: The highest quality data came from CS1, unfortunately it has been discontinued by the manufacturer. The optical sensors have not been ruled out for use, but more investigation is needed to determine how to get the best quality data. CS2 will be used in an

  9. Short-Term Thyroid Hormone Excess Affects the Heart but Does not Affect Adrenal Activity in Rats

    Energy Technology Data Exchange (ETDEWEB)

    Szkudlarek, Ariani Cavazzani, E-mail: arianiinaira@yahoo.com.br; Aldenucci, Bruno; Miyagui, Nelson Itiro; Silva, Ilana Kassouf [Universidade Federal do Paraná, Curitiba, PR (Brazil); Moraes, Rosana Nogueira [Pontifícia Universidade Federal do Paraná, Curitiba, PR (Brazil); Ramos, Helton Estrela [Universidade Federal da Bahia, Salvador, BA (Brazil); Fogaça, Rosalva Tadeu Hochmuller [Universidade Federal do Paraná, Curitiba, PR (Brazil)

    2014-03-15

    Hyperthyroidism (Hy) exerts a broad range of influences on a variety of physiological parameters. Its disruptive effect on cardiovascular system is one of its most remarkable impacts. Moreover, Hy has been clinically associated with stress - induced hyperactivation of the hypothalamic-pituitary-adrenal axis. Evaluate the impact of short-term Hy on cardiac performance and adrenal activity of rats. Induction of Hy in Wistar rats through injections of T3 (150 µg/kg) for 10 days (hyperthyroid group - HG) or vehicle (control group). The cardiovascular performance was evaluated by: echocardiography (ECHO); heart weight/body weight (mg/gr) ratio; contractility of isolated papillary muscles (IPM) and direct measurement of blood pressures. Adrenal activity was evaluated by adrenal weight/body weight (mg/gr) ratio and 24-hour fecal corticosterone (FC) levels on the, 5{sup th} and 10{sup th} days of T3 treatment. In HG, the ECHO showed reduction of the End Systolic and End Diastolic Volumes, Ejection, Total Diastolic and Isovolumic Relaxation Times, Diastolic and Systolic Areas and E/A ratio. Heart Rate, Ejection Fraction and Cardiac Output increased. The heart weight/body weight ratio was higher. Similarly, in IPM, the maximum rate of force decay during relaxation was higher in all extracellular calcium concentrations. Systolic blood pressure (SBP) levels were higher. (p ≤ 0.05). On the other hand, there was no difference in the adrenal weight/body weight ratio or in the 24-hour FC levels. Hy induces positive inotropic, chronotropic and lusitropic effects on the heart by direct effects of T3 and increases SBP. Those alterations are not correlated with changes in the adrenal activity.

  10. Short-Term Thyroid Hormone Excess Affects the Heart but Does not Affect Adrenal Activity in Rats

    Science.gov (United States)

    Szkudlarek, Ariani Cavazzani; Aldenucci, Bruno; Miyagui, Nelson Itiro; Silva, Ilana Kassouf; Moraes, Rosana Nogueira; Ramos, Helton Estrela; Fogaça, Rosalva Tadeu Hochmuller

    2014-01-01

    Background Hyperthyroidism (Hy) exerts a broad range of influences on a variety of physiological parameters. Its disruptive effect on cardiovascular system is one of its most remarkable impacts. Moreover, Hy has been clinically associated with stress - induced hyperactivation of the hypothalamic-pituitary-adrenal axis. Objective Evaluate the impact of short-term Hy on cardiac performance and adrenal activity of rats. Methods Induction of Hy in Wistar rats through injections of T3 (150 µg/kg) for 10 days (hyperthyroid group - HG) or vehicle (control group). The cardiovascular performance was evaluated by: echocardiography (ECHO); heart weight/body weight (mg/gr) ratio; contractility of isolated papillary muscles (IPM) and direct measurement of blood pressures. Adrenal activity was evaluated by adrenal weight/body weight (mg/gr) ratio and 24-hour fecal corticosterone (FC) levels on the, 5th and 10th days of T3 treatment. Results In HG, the ECHO showed reduction of the End Systolic and End Diastolic Volumes, Ejection, Total Diastolic and Isovolumic Relaxation Times, Diastolic and Systolic Areas and E/A ratio. Heart Rate, Ejection Fraction and Cardiac Output increased. The heart weight/body weight ratio was higher. Similarly, in IPM, the maximum rate of force decay during relaxation was higher in all extracellular calcium concentrations. Systolic blood pressure (SBP) levels were higher. (p ≤ 0.05). On the other hand, there was no difference in the adrenal weight/body weight ratio or in the 24-hour FC levels. Conclusions Hy induces positive inotropic, chronotropic and lusitropic effects on the heart by direct effects of T3 and increases SBP. Those alterations are not correlated with changes in the adrenal activity. PMID:24676225

  11. Short-Term Thyroid Hormone Excess Affects the Heart but Does not Affect Adrenal Activity in Rats

    International Nuclear Information System (INIS)

    Szkudlarek, Ariani Cavazzani; Aldenucci, Bruno; Miyagui, Nelson Itiro; Silva, Ilana Kassouf; Moraes, Rosana Nogueira; Ramos, Helton Estrela; Fogaça, Rosalva Tadeu Hochmuller

    2014-01-01

    Hyperthyroidism (Hy) exerts a broad range of influences on a variety of physiological parameters. Its disruptive effect on cardiovascular system is one of its most remarkable impacts. Moreover, Hy has been clinically associated with stress - induced hyperactivation of the hypothalamic-pituitary-adrenal axis. Evaluate the impact of short-term Hy on cardiac performance and adrenal activity of rats. Induction of Hy in Wistar rats through injections of T3 (150 µg/kg) for 10 days (hyperthyroid group - HG) or vehicle (control group). The cardiovascular performance was evaluated by: echocardiography (ECHO); heart weight/body weight (mg/gr) ratio; contractility of isolated papillary muscles (IPM) and direct measurement of blood pressures. Adrenal activity was evaluated by adrenal weight/body weight (mg/gr) ratio and 24-hour fecal corticosterone (FC) levels on the, 5 th and 10 th days of T3 treatment. In HG, the ECHO showed reduction of the End Systolic and End Diastolic Volumes, Ejection, Total Diastolic and Isovolumic Relaxation Times, Diastolic and Systolic Areas and E/A ratio. Heart Rate, Ejection Fraction and Cardiac Output increased. The heart weight/body weight ratio was higher. Similarly, in IPM, the maximum rate of force decay during relaxation was higher in all extracellular calcium concentrations. Systolic blood pressure (SBP) levels were higher. (p ≤ 0.05). On the other hand, there was no difference in the adrenal weight/body weight ratio or in the 24-hour FC levels. Hy induces positive inotropic, chronotropic and lusitropic effects on the heart by direct effects of T3 and increases SBP. Those alterations are not correlated with changes in the adrenal activity

  12. Dicty_cDB: FC-AJ15 [Dicty_cDB

    Lifescience Database Archive (English)

    Full Text Available FC (Link to library) FC-AJ15 (Link to dictyBase) - G01152 DDB0232964 Contig-U16520-...to library) Clone ID FC-AJ15 (Link to dictyBase) Atlas ID - NBRP ID G01152 dictyBase ID DDB0232964 Link to C...ontig Contig-U16520-1 Original site URL http://dictycdb.biol.tsukuba.ac.jp/CSM/FC...KIEFPLPDIKTKRKIFEI HTAKMNLSEDVNLEEFVMSKDDLSGADIKAICTESGLLALRERRMRVTHTDFKKAKEKVL YRKTAGAPEGLYM*kkknqnqk Trans...vih*qlviwrrlsmxitpschqp*tralcpyhvfv--- ---ELLNQLDGFDASTDVKVIMATNRIETLDPALIRPGRIDRKIEFPLPDIKTKRKIFEI HTAKMNLSEDVNLEEFVMSKDDLSGADIKAICT

  13. Paradoxical response to an emotional task: Trait characteristics and heart-rate dynamics

    NARCIS (Netherlands)

    Balocchia, R.; Varanini, M.; Paoletti, G.; Mecacci, G.; Santarcangelo, E.L.

    2015-01-01

    The present study evaluated the heart-rate dynamics of subjects reporting decreased (responders) or paradoxically increased relaxation (nonresponders) at the end of a threatening movie. Heart-rate dynamics were characterized by indices extracted through recurrence quantification analysis (RQA) and

  14. HEART RATE RECOVERY AFTER EXERCISE AND NEURAL REGULATION OF HEART RATE VARIABILITY IN 30-40 YEAR OLD FEMALE MARATHON RUNNERS

    Directory of Open Access Journals (Sweden)

    Toshio Matsuoka

    2005-03-01

    Full Text Available The aim of the present study was to examine the effects of endurance training on heart rate (HR recovery after exercise and cardiac autonomic nervous system (ANS modulation in female marathon runners by comparing with untrained controls. Six female marathon runners (M group aged 32-40 years and eight age-matched untrained females (C group performed a maximum-effort treadmill running exercise. Maximal oxygen uptake (VO2max was measured during the exercise with a gas analyzer connected to subjects through a face mask. Heart rate, blood pressure and blood lactate were measured before and after the exercise. Rating of perceived exertion (RPE to the exercise was obtained immediately after the exercise. Holter ECG was recorded and analyzed with power spectral analysis of heart rate variability (HRV to investigate the cardiac ANS modulation. The M group had significantly higher VO2max, faster HR recovery after exercise, higher Mean RR, SDRR, HF power and lower LF/HF ratio at rest compared with the C group. The M group also presented greater percent decrease of blood pressure after exercise, although their blood pressure after exercise was higher than the C group. It is suggested that endurance training induced significant alterations in cardiac ANS modulation at rest and significant acceleration of HR recovery after exercise in female marathon runners. Faster HR recovery after exercise in the female marathon runners should result from their higher levels of HRV, higher aerobic capacity and exaggerated blood pressure response to exercise compared with untrained controls.

  15. Heart rate variability based on risk stratification for type 2 diabetes mellitus.

    Science.gov (United States)

    Silva-E-Oliveira, Julia; Amélio, Pâmela Marina; Abranches, Isabela Lopes Laguardia; Damasceno, Dênis Derly; Furtado, Fabianne

    2017-01-01

    To evaluate heart rate variability among adults with different risk levels for type 2 diabetes mellitus. The risk for type 2 diabetes mellitus was assessed in 130 participants (89 females) based on the questionnaire Finnish Diabetes Risk Score and was classified as low risk (n=26), slightly elevated risk (n=41), moderate risk (n=27) and high risk (n=32). To measure heart rate variability, a heart-rate monitor Polar S810i® was employed to obtain RR series for each individual, at rest, for 5 minutes, followed by analysis of linear and nonlinear indexes. The groups at higher risk of type 2 diabetes mellitus had significantly lower linear and nonlinear heart rate variability indexes. The individuals at high risk for type 2 diabetes mellitus have lower heart rate variability. Avaliar a variabilidade da frequência cardíaca em adultos com diferentes níveis de risco para diabetes mellitus tipo 2. O grau de risco para diabetes mellitus tipo 2 de 130 participantes (41 homens) foi avaliado pelo questionário Finnish Diabetes Risk Score. Os participantes foram classificados em baixo risco (n=26), risco levemente elevado (n=41), risco moderado (n=27) e alto risco (n=32). Para medir a variabilidade da frequência cardíaca, utilizou-se o frequencímetro Polar S810i® para obter séries de intervalo RR para cada indivíduo, em repouso, durante 5 minutos; posteriormente, realizou-se análise por meio de índices lineares e não-lineares. O grupo com maior risco para diabetes mellitus tipo 2 teve uma diminuição significante nos índices lineares e não-lineares da variabilidade da frequência cardíaca. Os resultados apontam que indivíduos com risco alto para diabetes mellitus tipo 2 tem menor variabilidade da frequência cardíaca. To evaluate heart rate variability among adults with different risk levels for type 2 diabetes mellitus. The risk for type 2 diabetes mellitus was assessed in 130 participants (89 females) based on the questionnaire Finnish Diabetes Risk Score

  16. Immunization with avian metapneumovirus harboring chicken Fc induces higher immune responses.

    Science.gov (United States)

    Paudel, Sarita; Easwaran, Maheswaran; Jang, Hyun; Jung, Ho-Kyoung; Kim, Joo-Hun; Shin, Hyun-Jin

    2016-07-15

    In this study, we evaluated the immune responses of avian metapneumovirus harboring chicken Fc molecule. Stable Vero cells expressing chicken Fc chimera on its surface (Vero-cFc) were established, and we confirmed that aMPV grown in Vero-cFc incorporated host derived chimera Fc into the aMPV virions. Immunization of chicken with aMPV-cFc induced higher level of antibodies and inflammatory cytokines; (Interferon (IFN)-γ and Interleukin (IL)-1β) compared to those of aMPV. The increased levels of antibodies and inflammatory cytokines in chicken immunized with aMPV-cFc were statistically significantly (p<0.05) to that of aMPV and control. The aMPV-cFc group also generated the highest neutralizing antibody response. After challenges, chickens immunized with aMPV-cFc showed much less pathological signs in nasal turbinates and trachea so that we could confirm aMPV-cFc induced higher protection than that of aMPV. The greater ability of aMPV harboring chicken Fc to that of aMPV presented it as a possible vaccine candidate. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Heart rate variability in normal-weight patients with polycystic ovary syndrome.

    Science.gov (United States)

    Kilit, Celal; Paşalı Kilit, Türkan

    2017-05-01

    Polycystic ovary syndrome (PCOS) is an endocrine disease closely related to several risk factors of cardiovascular disease. Obese women with PCOS show altered autonomic modulation. The results of studies investigating cardiac autonomic functions of normal-weight women with PCOS are conflicting. The aim of the study was to assess the reactivity of cardiac sympathovagal balance in normal-weight women with PCOS by heart rate variability analysis. We examined the heart rate variability in 60 normal-weight women with PCOS and compared them with that in 60 age-matched healthy women having a similar metabolic profile. Time and frequency domain parameters of heart rate variability were analyzed based on 5-min-long continuous electrocardiography recordings for the following 3 periods: (1) during rest in supine position, (2) during controlled breathing, and (3) during isometric handgrip exercise. Time and frequency domain parameters of heart rate variability for the 3 periods assessed were similar in the two groups. Although modified Ferriman-Gallwey score and serum testosterone and luteinizing hormone levels were significantly higher in women with PCOS, homeostatic model assessment-insulin resistance (HOMA-IR) was not different the between the PCOS and control groups. There were no significant correlations between serum testosterone levels and heart rate variability parameters among the study population. The findings of this study suggest that the reactivity of cardiac sympathovagal balance is not altered in normal-weight women with PCOS having a normal HOMA-IR.

  18. Abnormal heart rate recovery and deficient chronotropic response after submaximal exercise in young Marfan syndrome patients.

    Science.gov (United States)

    Peres, Paulo; Carvalho, Antônio C; Perez, Ana Beatriz A; Medeiros, Wladimir M

    2016-10-01

    Marfan syndrome patients present important cardiac structural changes, ventricular dysfunction, and electrocardiographic changes. An abnormal heart rate response during or after exercise is an independent predictor of mortality and autonomic dysfunction. The aim of the present study was to compare heart rate recovery and chronotropic response obtained by cardiac reserve in patients with Marfan syndrome subjected to submaximal exercise. A total of 12 patients on β-blocker therapy and 13 off β-blocker therapy were compared with 12 healthy controls. They were subjected to submaximal exercise with lactate measurements. The heart rate recovery was obtained in the first minute of recovery and corrected for cardiac reserve and peak lactate concentration. Peak heart rate (141±16 versus 155±17 versus 174±8 bpm; p=0.001), heart rate reserve (58.7±9.4 versus 67.6±14.3 versus 82.6±4.8 bpm; p=0.001), heart rate recovery (22±6 versus 22±8 versus 34±9 bpm; p=0.001), and heart rate recovery/lactate (3±1 versus 3±1 versus 5±1 bpm/mmol/L; p=0.003) were different between Marfan groups and controls, respectively. All the patients with Marfan syndrome had heart rate recovery values below the mean observed in the control group. The absolute values of heart rate recovery were strongly correlated with the heart rate reserve (r=0.76; p=0.001). Marfan syndrome patients have reduced heart rate recovery and chronotropic deficit after submaximal exercise, and the chronotropic deficit is a strong determinant of heart rate recovery. These changes are suggestive of autonomic dysfunction.

  19. Chicken IgY Fc linked to Bordetella avium ompA and Taishan Pinus massoniana pollen polysaccharide adjuvant enhances macrophage function and specific immune responses

    Directory of Open Access Journals (Sweden)

    Zhu Ruiliang

    2016-11-01

    Full Text Available Fc-fusion technologies, in which immunoglobulin Fc is genetically fused to an antigenic protein, have been developed to confer antibody-like properties to proteins and peptides. Mammalian IgG Fc fusion exhibits improved antigen-induced immune responses by providing aggregates with high avidity for the IgG Fc receptor and salvaging the antigenic portion from endosomal degradation. However, whether the linked chicken IgY Fc fragment shares similar characteristics to mammalian IgG Fc remains unclear. In this study, we linked the chicken IgY Fc gene to the outer membrane protein A (ompA of Borderella avium through overlapping PCR. The fusion gene was cloned into the pPIC9 plasmid to construct the recombinant Pichia pastoris transformant expressing the ompA–Fc fusion protein. The effects of the linked Fc on macrophage vitality, activity, efficiency of antigen processing, and immune responses induced by the fused ompA were investigated. Furthermore, the effect of Taishan Pinus massoniana pollen polysaccharide (TPPPS, an immunomodulator, on chicken macrophage activation was evaluated. TPPPS was also used as an adjuvant to investigate its immunomodulatory effect on immunoresponses induced by the fused ompA–Fc in chickens. The pinocytosis, phagocytosis, secretion of nitric oxide and TNF-α, and MHC-II molecular expression of the macrophages treated with the fused ompA–Fc were significantly higher than those of the macrophages treated with ompA alone. The addition of TPPPS to the fused ompA–Fc further enhanced macrophage functions. The fused ompA–Fc elicited higher antigen-specific immune responses and protective efficacy compared with ompA alone. Moreover, the fused ompA–Fc conferred higher serum antibody titers, serum IL-2 and IL-4 concentrations, CD4+ and CD8+ T-lymphocyte counts, lymphocyte transformation rate, and protection rate compared with ompA alone. Notably, the prepared TPPPS adjuvant ompA–Fc vaccines induced high immune

  20. Reduced heart rate variability in social anxiety disorder: associations with gender and symptom severity.

    Directory of Open Access Journals (Sweden)

    Gail A Alvares

    Full Text Available BACKGROUND: Polyvagal theory emphasizes that autonomic nervous system functioning plays a key role in social behavior and emotion. The theory predicts that psychiatric disorders of social dysfunction are associated with reduced heart rate variability, an index of autonomic control, as well as social inhibition and avoidance. The purpose of this study was to examine whether heart rate variability was reduced in treatment-seeking patients diagnosed with social anxiety disorder, a disorder characterized by social fear and avoidance. METHODS: Social anxiety patients (n = 53 were recruited prior to receiving psychological therapy. Healthy volunteers were recruited through the University of Sydney and the general community and were matched by gender and age (n = 53. Heart rate variability was assessed during a five-minute recording at rest, with participants completing a range of self-report clinical symptom measures. RESULTS: Compared to controls, participants with social anxiety exhibited significant reductions across a number of heart rate variability measures. Reductions in heart rate variability were observed in females with social anxiety, compared to female controls, and in patients taking psychotropic medication compared to non-medicated patients. Finally, within the clinical group, we observed significant associations between reduced heart rate variability and increased social interaction anxiety, psychological distress, and harmful alcohol use. CONCLUSIONS: The results of this study confirm that social anxiety disorder is associated with reduced heart rate variability. Resting state heart rate variability may therefore be considered a marker for social approach-related motivation and capacity for social engagement. Additionally, heart rate variability may provide a useful biomarker to explain underlying difficulties with social approach, impaired stress regulation, and behavioral inhibition, especially in disorders associated with

  1. Heart rate and activity profile for young female soccer players

    OpenAIRE

    Barbero Álvarez, José Carlos; Gómez López, Maite; Barbero Álvarez, Verónica; Granda Vera, Juan; Castagna, Carlo

    2008-01-01

    The physical and physiological demands of high-level male soccer have been studied extensively, while few studies have investigated the demands placed on females during match-play, however, there is no information available about the heart rate and activity profile of young female soccer players during match play. Therefore, the aim of this study was to examine cardiovascular (heart-rates HR) and physical demands of young female soccer players during a match. Players were observed during a fr...

  2. Analytical FcRn affinity chromatography for functional characterization of monoclonal antibodies

    Science.gov (United States)

    Schlothauer, Tilman; Rueger, Petra; Stracke, Jan Olaf; Hertenberger, Hubert; Fingas, Felix; Kling, Lothar; Emrich, Thomas; Drabner, Georg; Seeber, Stefan; Auer, Johannes; Koch, Stefan; Papadimitriou, Apollon

    2013-01-01

    The neonatal Fc receptor (FcRn) is important for the metabolic fate of IgG antibodies in vivo. Analysis of the interaction between FcRn and IgG in vitro might provide insight into the structural and functional integrity of therapeutic IgG that may affect pharmacokinetics (PK) in vivo. We developed a standardized pH gradient FcRn affinity liquid chromatography method with conditions closely resembling the physiological mechanism of interaction between IgG and FcRn. This method allows the separation of molecular IgG isoforms, degradation products and engineered molecules based on their affinity to FcRn. Human FcRn was immobilized on the column and a linear pH gradient from pH 5.5 to 8.8 was applied. FcRn chromatography was used in comparison to surface plasmon resonance to characterize different monoclonal IgG preparations, e.g., oxidized or aggregated species. Wild-type and engineered IgGs were compared in vitro by FcRn chromatography and in vivo by PK studies in huFcRn transgenic mice. Analytical FcRn chromatography allows differentiation of IgG samples and variants by peak pattern and retention time profile. The method can distinguish: 1) IgGs with different Fabs, 2) oxidized from native IgG, 3) aggregates from monomer and 4) antibodies with mutations in the Fc part from wild-type IgGs. Changes in the FcRn chromatographic behavior of mutant IgGs relative to the wild-type IgG correlate to changes in the PK profile in the FcRn transgenic mice. These results demonstrate that FcRn affinity chromatography is a useful new method for the assessment of IgG integrity. PMID:23765230

  3. Music close to one's heart: heart rate variability with music, diagnostic with e-bra and smartphone

    Science.gov (United States)

    Hegde, Shantala; Kumar, Prashanth S.; Rai, Pratyush; Mathur, Gyanesh N.; Varadan, Vijay K.

    2012-04-01

    Music is a powerful elicitor of emotions. Emotions evoked by music, through autonomic correlates have been shown to cause significant modulation of parameters like heart rate and blood pressure. Consequently, Heart Rate Variability (HRV) analysis can be a powerful tool to explore evidence based therapeutic functions of music and conduct empirical studies on effect of musical emotion on heart function. However, there are limitations with current studies. HRV analysis has produced variable results to different emotions evoked via music, owing to variability in the methodology and the nature of music chosen. Therefore, a pragmatic understanding of HRV correlates of musical emotion in individuals listening to specifically chosen music whilst carrying out day to day routine activities is needed. In the present study, we aim to study HRV as a single case study, using an e-bra with nano-sensors to record heart rate in real time. The e-bra developed previously, has several salient features that make it conducive for this study- fully integrated garment, dry electrodes for easy use and unrestricted mobility. The study considers two experimental conditions:- First, HRV will be recorded when there is no music in the background and second, when music chosen by the researcher and by the subject is playing in the background.

  4. Increased heart rate variability but normal resting metabolic rate in hypocretin/orexin-deficient human narcolepsy.

    NARCIS (Netherlands)

    Fronczek, R.; Overeem, S.; Reijntjes, R.; Lammers, G.J.; Dijk, J.G.M.; Pijl, H.

    2008-01-01

    STUDY OBJECTIVES: We investigated autonomic balance and resting metabolic rate to explore their possible involvement in obesity in hypocretin/orexin-deficient narcoleptic subjects. METHODS: Resting metabolic rate (using indirect calorimetry) and variability in heart rate and blood pressure were

  5. Vigorous physical activity predicts higher heart rate variability among younger adults.

    Science.gov (United States)

    May, Richard; McBerty, Victoria; Zaky, Adam; Gianotti, Melino

    2017-06-14

    Baseline heart rate variability (HRV) is linked to prospective cardiovascular health. We tested intensity and duration of weekly physical activity as predictors of heart rate variability in young adults. Time and frequency domain indices of HRV were calculated based on 5-min resting electrocardiograms collected from 82 undergraduate students. Hours per week of both moderate and vigorous activity were estimated using the International Physical Activity Questionnaire. In regression analyses, hours of vigorous physical activity, but not moderate activity, significantly predicted greater time domain and frequency domain indices of heart rate variability. Adjusted for weekly frequency, greater daily duration of vigorous activity failed to predict HRV indices. Future studies should test direct measurements of vigorous activity patterns as predictors of autonomic function in young adulthood.

  6. Determination of heart rate variability with an electronic stethoscope.

    Science.gov (United States)

    Kamran, Haroon; Naggar, Isaac; Oniyuke, Francisca; Palomeque, Mercy; Chokshi, Priya; Salciccioli, Louis; Stewart, Mark; Lazar, Jason M

    2013-02-01

    Heart rate variability (HRV) is widely used to characterize cardiac autonomic function by measuring beat-to-beat alterations in heart rate. Decreased HRV has been found predictive of worse cardiovascular (CV) outcomes. HRV is determined from time intervals between QRS complexes recorded by electrocardiography (ECG) for several minutes to 24 h. Although cardiac auscultation with a stethoscope is performed routinely on patients, the human ear cannot detect heart sound time intervals. The electronic stethoscope digitally processes heart sounds, from which cardiac time intervals can be obtained. Accordingly, the objective of this study was to determine the feasibility of obtaining HRV from electronically recorded heart sounds. We prospectively studied 50 subjects with and without CV risk factors/disease and simultaneously recorded single lead ECG and heart sounds for 2 min. Time and frequency measures of HRV were calculated from R-R and S1-S1 intervals and were compared using intra-class correlation coefficients (ICC). The majority of the indices were strongly correlated (ICC 0.73-1.0), while the remaining indices were moderately correlated (ICC 0.56-0.63). In conclusion, we found HRV measures determined from S1-S1 are in agreement with those determined by single lead ECG, and we demonstrate and discuss differences in the measures in detail. In addition to characterizing cardiac murmurs and time intervals, the electronic stethoscope holds promise as a convenient low-cost tool to determine HRV in the hospital and outpatient settings as a practical extension of the physical examination.

  7. Estimating Energy Expenditure from Heart Rate in Older Adults: A Case for Calibration

    OpenAIRE

    Schrack, Jennifer A.; Zipunnikov, Vadim; Goldsmith, Jeff; Bandeen-Roche, Karen; Crainiceanu, Ciprian M.; Ferrucci, Luigi

    2014-01-01

    Background Accurate measurement of free-living energy expenditure is vital to understanding changes in energy metabolism with aging. The efficacy of heart rate as a surrogate for energy expenditure is rooted in the assumption of a linear function between heart rate and energy expenditure, but its validity and reliability in older adults remains unclear. Objective To assess the validity and reliability of the linear function between heart rate and energy expenditure in older adults using diffe...

  8. Evaluation of therapy for dilated cardiomyopathy with heart failure by iodine-123 metaiodobenzyl-guanidine imaging. Comparison with heart rate variability power spectral analysis

    Energy Technology Data Exchange (ETDEWEB)

    Li, Shou-lin; Ikeda, Jun; Takita, Tamotsu; Sekiguchi, Yohei; Demachi, Jun; Chikama, Hisao; Goto, Atsushi; Shirato, Kunio [Tohoku Univ., Sendai (Japan). School of Medicine

    1998-11-01

    The relationship between the myocardial uptake of iodine-123 metaiodobenzylguanidine ({sup 123}I-MIBG) and heart rate variability parameters has not been determined. This study determined the relationship between the change in myocardial uptake of {sup 123}I-MIBG and improvement in left ventricular function after treatment, to determine the usefulness of {sup 123}I-MIBG imaging to assess the effect of therapy on heart failure due to dilated cardiomyopathy (DCM). {sup 123}I-MIBG imaging and power spectral analysis of heart rate variability were performed before and after treatment in 17 patients with heart failure due to DCM. The following parameters were compared before and after treatment: New York Heart Association (NYHA) functional class, radiographic cardiothoracic ratio (CTR), blood pressure, echocardiographic data (left ventricular end-systolic (LVDs) and end-diastolic (LVDd) diameters, left ventricular ejection fraction (LVEF)), plasma concentrations of norepinephrine and epinephrine, heart rate variability power spectral analysis data (mean low frequency (MLF) and high frequency power (MHF)) and the myocardium to mediastinum activity ratio (MYO/M) obtained in early and late images, and washout rate calculated by anterior planar imaging of {sup 123}I-MIBG. The NYHA functional class, LVEF, LVDs, CTR, MLF and MHF improved after treatment. Early MYO/M and late MYO/M improved after treatment. The rate of increase in late MYO/M was positively correlated with the rate of improvement of LVEF after treatment. Furthermore, the late MYO/M was negatively correlated with MLF. Washout rate revealed no correlation with hemodynamic parameters. These findings suggest that late MYO/M is more useful than washout rate to assess the effect of treatment on heart failure due to DCM. Furthermore, the {sup 123}I-MIBG imaging and heart rate variability parameters are useful to assess the autonomic tone in DCM with heart failure. (author)

  9. Evaluation of therapy for dilated cardiomyopathy with heart failure by iodine-123 metaiodobenzyl-guanidine imaging. Comparison with heart rate variability power spectral analysis

    International Nuclear Information System (INIS)

    Li, Shou-lin; Ikeda, Jun; Takita, Tamotsu; Sekiguchi, Yohei; Demachi, Jun; Chikama, Hisao; Goto, Atsushi; Shirato, Kunio

    1998-01-01

    The relationship between the myocardial uptake of iodine-123 metaiodobenzylguanidine ( 123 I-MIBG) and heart rate variability parameters has not been determined. This study determined the relationship between the change in myocardial uptake of 123 I-MIBG and improvement in left ventricular function after treatment, to determine the usefulness of 123 I-MIBG imaging to assess the effect of therapy on heart failure due to dilated cardiomyopathy (DCM). 123 I-MIBG imaging and power spectral analysis of heart rate variability were performed before and after treatment in 17 patients with heart failure due to DCM. The following parameters were compared before and after treatment: New York Heart Association (NYHA) functional class, radiographic cardiothoracic ratio (CTR), blood pressure, echocardiographic data (left ventricular end-systolic (LVDs) and end-diastolic (LVDd) diameters, left ventricular ejection fraction (LVEF)), plasma concentrations of norepinephrine and epinephrine, heart rate variability power spectral analysis data (mean low frequency (MLF) and high frequency power (MHF)) and the myocardium to mediastinum activity ratio (MYO/M) obtained in early and late images, and washout rate calculated by anterior planar imaging of 123 I-MIBG. The NYHA functional class, LVEF, LVDs, CTR, MLF and MHF improved after treatment. Early MYO/M and late MYO/M improved after treatment. The rate of increase in late MYO/M was positively correlated with the rate of improvement of LVEF after treatment. Furthermore, the late MYO/M was negatively correlated with MLF. Washout rate revealed no correlation with hemodynamic parameters. These findings suggest that late MYO/M is more useful than washout rate to assess the effect of treatment on heart failure due to DCM. Furthermore, the 123 I-MIBG imaging and heart rate variability parameters are useful to assess the autonomic tone in DCM with heart failure. (author)

  10. Reliability of heart rate mobile apps in young healthy adults: exploratory study and research directions

    Directory of Open Access Journals (Sweden)

    Maria Parpinel

    2017-06-01

    Full Text Available Background: Recently, a number of smartphone apps appeared that allow for heart rate measurements basing on the photoplethysmography principle. In fact, almost every smartphone now has a camera with flash that could be used for that. Some studies appeared on the reliability of some of those apps, with heterogeneous results. Objectives: The present study aims at adding up evidence in particular during physical activity, by comparing 3 apps on two different platforms (IOs and Android, on a broad range of heart rates. As gold standard, heart rate has been measured with a traditional heart rate monitor. Results: The results suggest that heart rate apps might be used for measuring heart rate for fitness aims for many individuals, but further research is needed to i analyse influence of smartphone features; ii identify personal factors hindering measurements, and iii verify reliability on different measurement sites.

  11. Heart rate profiles and energy cost of locomotion during cross-country skiing races.

    Science.gov (United States)

    Mognoni, P; Rossi, G; Gastaldelli, F; Canclini, A; Cotelli, F

    2001-07-01

    The purpose of this study was to compare heart rate responses and speed in two cross-country skiing races, which were run by seven male and seven female subjects by using classic and free style. Heart rates and skiing velocities were analyzed over flat, uphill and downhill sections, which were run from one to three times. Heart rates were higher in uphill sections than in flat sections; a steady-state heart rate was never reached in the downhill section. When the same uphill section was repeated, the heart rate tended to increase but the speed to decrease. Oxygen uptake (VO2) was calculated from heart rate:VO2 ratio, measured during uphill walking with the aid of poles. The mean (SD) energy cost of locomotion (i.e., the ratio between net VO2 and speed) was 162.1 (9.4) ml.km(-1).kg(-1) and 147.7 (7.1) ml.km(-1).kg(-1) when male subjects ran the flat section after first downhill by using classic and free style, respectively. Females had lower values for VO2 and speed, but similar energy costs. In general, the variability of the energy cost of locomotion in skiers of a similar competitive level is of the same order as that found in uphill walking on a treadmill.

  12. Assessing Metabolic Syndrome Through Increased Heart Rate During Exercise

    Directory of Open Access Journals (Sweden)

    Masoumeh Sadeghi

    2016-12-01

    Full Text Available The present study aimed to assess changes in resting and maximum heart rates as primary indicators of cardiac autonomic function in metabolic syndrome (MetS patients and to determine their value for discriminating MetS from non-MetS. 468 participants were enrolled in this cross-sectional study and assessed according to the updated adult treatment panel III (ATP-III definition of MetS. Resting and maximum heart rates were recorded following the Bruce protocol during an exercise. A receiver operating characteristic (ROC curve was used to identify the best cutoff point for discriminating MetS from the non-MetS state. 194 participants (41.5% were diagnosed as MetS. The mean resting heart rate (RHR was not statistically different between the two groups (P=0.078. However, the mean maximum heart (MHR rate was considerably higher in participants with MetS (142.37±14.84 beats per min compared to the non-MetS group (134.62±21.63 beats per min (P<0.001. In the MetS group, the MHR was positively correlated with the serum triglyceride level (β=0.185, P=0.033 and was inversely associated with age (β=-0.469, P<0.001. The MHR had a moderate value for discriminating MetS from the non-MetS state (c=0.580, P=0.004 with the optimal cutoff point of 140 beats per min. In MetS patients, the MHR was significantly greater compared to non-MetS subjects and was directly correlated with serum triglyceride levels and inversely with advanced age. Moreover, MHR can be used as a suspicious indicator for identifying MetS.

  13. Assessing Metabolic Syndrome Through Increased Heart Rate During Exercise.

    Science.gov (United States)

    Sadeghi, Masoumeh; Gharipour, Mojgan; Nezafati, Pouya; Shafie, Davood; Aghababaei, Esmaeil; Sarrafzadegan, Nizal

    2016-11-01

    The present study aimed to assess changes in resting and maximum heart rates as primary indicators of cardiac autonomic function in metabolic syndrome (MetS) patients and to determine their value for discriminating MetS from non-MetS. 468 participants were enrolled in this cross-sectional study and assessed according to the updated adult treatment panel III (ATP-III) definition of MetS. Resting and maximum heart rates were recorded following the Bruce protocol during an exercise. A receiver operating characteristic (ROC) curve was used to identify the best cutoff point for discriminating MetS from the non-MetS state. 194 participants (41.5%) were diagnosed as MetS. The mean resting heart rate (RHR) was not statistically different between the two groups (P=0.078). However, the mean maximum heart (MHR) rate was considerably higher in participants with MetS (142.37±14.84 beats per min) compared to the non-MetS group (134.62±21.63 beats per min) (P<0.001). In the MetS group, the MHR was positively correlated with the serum triglyceride level (β=0.185, P=0.033) and was inversely associated with age (β=-0.469, P<0.001). The MHR had a moderate value for discriminating MetS from the non-MetS state (c=0.580, P=0.004) with the optimal cutoff point of 140 beats per min. In MetS patients, the MHR was significantly greater compared to non-MetS subjects and was directly correlated with serum triglyceride levels and inversely with advanced age. Moreover, MHR can be used as a suspicious indicator for identifying MetS.

  14. 256-slice CT coronary angiography in atrial fibrillation: The impact of mean heart rate and heart rate variability on image quality

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Liang-Kuang [Department of Radiology, Shin Kong Wu Ho-Su Memorial Hospital, Taipei, Taiwan (China); College of Medicine, Fu Jen Catholic University, Taipei, Taiwan (China); Hsu, Shih-Ming [Department of Biomedical Imaging and Radiological Science, China Medical University, Taichung, Taiwan (China); Mok, Greta S.P. [Department of Electrical and Electronics Engineering, Faculty of Science and Technology, University of Macau, Macau (China); Law, Wei-Yip; Lu, Kun-Mu [Department of Radiology, Shin Kong Wu Ho-Su Memorial Hospital, Taipei, Taiwan (China); Yang, Ching-Ching, E-mail: g39220003@yahoo.com.tw [Department of Radiological Technology, Tzu Chi College of Technology, 880, Sec.2, Chien-kuo Rd. Hualien 970, Taiwan (China); Wu, Tung-Hsin, E-mail: tung@ym.edu.tw [Department of Biomedical Imaging and Radiological Sciences, National Yang Ming University, 155 Li-Nong St., Sec. 2, Taipei 112, Taiwan (China)

    2011-08-21

    Objective: The aim of this study was to evaluate the image quality of 256-MDCT in atrial fibrillation and to compare the findings with those among patients in sinus rhythm. Materials: All reconstructed images were evaluated by two independent experienced readers blinded to patient information, heart rate, and ECG results to assess the diagnostic quality of images of the coronary artery segments using axial images, multi-planar reformations, maximum intensity projections, and volume rendering technique. Results: No statistical significance was detected in terms of the overall image quality between patients in sinus rhythm and with atrial fibrillation. Pearson's correlation analysis showed no significant association between image quality and mean heart rate no matter for patients in sinus rhythm or with atrial fibrillation. Similarly, there was no correlation between image quality and heart rate variability for either patients in sinus rhythm or with atrial fibrillation. Our results showed that the optimal reconstruction window depends on patient's HR, and the pattern for patients in atrial fibrillation is similar to that obtained from non-atrial fibrillation patients. Conclusion: This study shows the potential of using 256-MDCT coronary angiography in patients with atrial fibrillation. Our results suggest that when appropriate reconstruction timing window is applied, patients with atrial fibrillation do not have to be excluded from MDCT coronary angiographic examinations.

  15. 256-slice CT coronary angiography in atrial fibrillation: The impact of mean heart rate and heart rate variability on image quality

    International Nuclear Information System (INIS)

    Chen, Liang-Kuang; Hsu, Shih-Ming; Mok, Greta S.P.; Law, Wei-Yip; Lu, Kun-Mu; Yang, Ching-Ching; Wu, Tung-Hsin

    2011-01-01

    Objective: The aim of this study was to evaluate the image quality of 256-MDCT in atrial fibrillation and to compare the findings with those among patients in sinus rhythm. Materials: All reconstructed images were evaluated by two independent experienced readers blinded to patient information, heart rate, and ECG results to assess the diagnostic quality of images of the coronary artery segments using axial images, multi-planar reformations, maximum intensity projections, and volume rendering technique. Results: No statistical significance was detected in terms of the overall image quality between patients in sinus rhythm and with atrial fibrillation. Pearson's correlation analysis showed no significant association between image quality and mean heart rate no matter for patients in sinus rhythm or with atrial fibrillation. Similarly, there was no correlation between image quality and heart rate variability for either patients in sinus rhythm or with atrial fibrillation. Our results showed that the optimal reconstruction window depends on patient's HR, and the pattern for patients in atrial fibrillation is similar to that obtained from non-atrial fibrillation patients. Conclusion: This study shows the potential of using 256-MDCT coronary angiography in patients with atrial fibrillation. Our results suggest that when appropriate reconstruction timing window is applied, patients with atrial fibrillation do not have to be excluded from MDCT coronary angiographic examinations.

  16. Robust efficient estimation of heart rate pulse from video

    Science.gov (United States)

    Xu, Shuchang; Sun, Lingyun; Rohde, Gustavo Kunde

    2014-01-01

    We describe a simple but robust algorithm for estimating the heart rate pulse from video sequences containing human skin in real time. Based on a model of light interaction with human skin, we define the change of blood concentration due to arterial pulsation as a pixel quotient in log space, and successfully use the derived signal for computing the pulse heart rate. Various experiments with different cameras, different illumination condition, and different skin locations were conducted to demonstrate the effectiveness and robustness of the proposed algorithm. Examples computed with normal illumination show the algorithm is comparable with pulse oximeter devices both in accuracy and sensitivity. PMID:24761294

  17. Mental load, heart rate and heart rate variability.

    NARCIS (Netherlands)

    Blitz, P.S.; Hoogstraten, J.; Mulder, G.

    1970-01-01

    "Several investigators have shown that diminished sinus arrhythmia can be seen as an indication of increased mental load. The present experiment deals with the influence of different levels of mental load, operationalized as the number of binary choices per minute, on the regularity of the heart

  18. Structural and functional changes of the heart in patients with chronic ischemic heart failure, associated with renal dysfunction

    Directory of Open Access Journals (Sweden)

    D. A. Lashkul

    2014-04-01

    Full Text Available Kidney disease is a frequent complication of congestive heart failure (CHF and may contribute to the progression of ventricular dysfunction. Regardless of the degree of heart failure, chronic kidney disease (CKD increases the risk of death and cardiac decompensation. Left ventricular hypertrophy (LVH is a known parameter of cardiac remodelling and has a higher prevalence and incidence among people with impaired kidney function. LVH is an early subclinical marker of cardiovascular disease and heart failure risk, and is probably an intermediary step in the pathway leading from kidney dysfunction to heart failure and its complications. The effects of CKD on other left ventricular and myocardial parameters, however, have been less characterized. The aim of the study was to examine the structural and functional changes, geometric remodeling of the heart in patients with ischemic chronic heart failure, being hospitalized, according to the presence of renal dysfunction. Materials and methods. The study involved 333 patients with ischemic CHF (277 men and 56 women, mean age 59,3±9,4 years. The functional class of heart failure was assessed on the recommendations of the New York Heart Association (NYHA. The etiology of heart failure in 288 (86.5% patients had a combination of coronary artery disease and essential hypertension, in 45 (13.5% – only CAD. 1 FC of heart failure was diagnosed in 9 (2.7% patients, 2 FC - in 106 (31.8%, 3 FC - in 199 (59.8% and 4 FC - 19 (5.7% patients. Diabetes was in 61 (18.3%, myocardial infarction history was in 240 (72.1% patients. Depending on the glomerular filtration rate, patients were divided into 3 groups: 72 with normal GFR (>90 ml/min/1.73m2, 218 with a slight decrease in GFR (60-90 ml/min/1.73m2 and 43 with moderate reduced GFR (<60 ml/min/1.73m2. Echocardiography was performed using the General Electric VIVID 3 system (General Electric Healthcare, USA with the 2.5–3.5 MHz transducer and Doppler technique

  19. The Fc-receptor III of cultured human monocytes. Structural similarity with FcRIII of natural killer cells and role in the extracellular lysis of sensitized erythrocytes

    NARCIS (Netherlands)

    Klaassen, R. J.; Ouwehand, W. H.; Huizinga, T. W.; Engelfriet, C. P.; von dem Borne, A. E.

    1990-01-01

    FcRIII is not present on peripheral blood monocytes, but becomes expressed upon culturing and can be demonstrated on tissue macrophages. We studied the expression of FcRIII of cultured monocytes in detail and compared its structure with FcRIII of neutrophils and NK cells. The cell density of FcRIII

  20. Electrocardiogram application based on heart rate variability ontology and fuzzy markup language

    NARCIS (Netherlands)

    Wang, M.-H.; Lee, C.-S.; Acampora, G.; Loia, V.; Gacek, A.; Pedrycz, W.

    2011-01-01

    The electrocardiogram (ECG) signal is adopted extensively as a low-cost diagnostic procedure to provide information concerning the healthy status of the heart. Heart rate variability (HRV) is a physiological phenomenon where the time interval between heart beats varies. It is measured by the

  1. Onset of decreased heart work is correlated with increased heart rate and shortened QT interval in high-carbohydrate fed overweight rats.

    Science.gov (United States)

    Durak, Aysegul; Olgar, Yusuf; Tuncay, Erkan; Karaomerlioglu, Irem; Kayki Mutlu, Gizem; Arioglu Inan, Ebru; Altan, Vecdi Melih; Turan, Belma

    2017-11-01

    Mechanical activity of the heart is adversely affected in metabolic syndrome (MetS) characterized by increased body mass and marked insulin resistance. Herein, we examined the effects of high carbohydrate intake on cardiac function abnormalities by evaluating in situ heart work, heart rate, and electrocardiograms (ECGs) in rats. MetS was induced in male Wistar rats by adding 32% sucrose to drinking water for 22-24 weeks and was confirmed by insulin resistance, increased body weight, increased blood glucose and serum insulin, and increased systolic and diastolic blood pressures in addition to significant loss of left ventricular integrity and increased connective tissue around myofibrils. Analysis of in situ ECG recordings showed a markedly shortened QT interval and decreased QRS amplitude with increased heart rate. We also observed increased oxidative stress and decreased antioxidant defense characterized by decreases in serum total thiol level and attenuated paraoxonase and arylesterase activities. Our data indicate that increased heart rate and a shortened QT interval concomitant with higher left ventricular developed pressure in response to β-adrenoreceptor stimulation as a result of less cyclic AMP release could be regarded as a natural compensation mechanism in overweight rats with MetS. In addition to the persistent insulin resistance and obesity associated with MetS, one should consider the decreased heart work, increased heart rate, and shortened QT interval associated with high carbohydrate intake, which may have more deleterious effects on the mammalian heart.

  2. Heart Rates of Elementary Physical Education Students during the Dancing Classrooms Program

    Science.gov (United States)

    Nelson, Larry; Evans, Melissa; Guess, Wendy; Morris, Mary; Olson, Terry; Buckwalter, John

    2011-01-01

    We examined how different types of dance activities, along with their duration, influenced heart rate responses among fifth-grade physical education students (N = 96) who participated in the Dancing Classrooms program. Results indicated that the overall Dancing Classrooms program elicits a moderate cardiovascular heart rate response (M = 124.4…

  3. Heart rate variability and heart rate turbulence in patients with polycystic ovary syndrome.

    Science.gov (United States)

    Özkeçeci, Gülay; Ünlü, Bekir Serdar; Dursun, Hüseyin; Akçi, Önder; Köken, Gülengül; Onrat, Ersel; Avşar, Alaettin

    2016-05-01

    Cardiac autonomic dysfunction may develop in patients with polycystic ovary syndrome (PCOS). Heart rate variability (HRV) and heart rate turbulence (HRT) are used in assessing cardiac autonomic functions. The goal of this study was to compare the cardiac autonomic functions in patients with PCOS and healthy controls. To our knowledge, this is the first study evaluating cardiac autonomic functions in patients with PCOS with respect to both HRV and HRT. Twenty-three patients with PCOS (mean age 22.8±3.9 years) and 25 healthy female volunteers who were matched for age and body mass index (BMI) (mean age 23.5±6.2 years) were enrolled in this as case-control study. Twenty-four hour ambulatory electrocardiogram recordings of all participants were taken using Pathfinder software. The time domain parameters of HRV and HRT, including turbulence onset (TO) and turbulence slope, were calculated. Diagnosis of PCOS was made with physical and laboratory findings of hirsutism or biochemical hyperandrogenism and chronic anovulation. Diabetes mellitus, other hormon disorders or hormon therapy, pregnancy, atrial fibrilation, obesite, chronic diseases, disorders of the autonomic nervous system, a history of drug use affecting the autonomic nervous system were excluded. There were no significant differences in HRV and HRT parameters between the two groups. Cardiovascular risk factors, such as BMI, blood pressure, fasting blood glucose, and lipid parameters, were also similar. Triangular index measure of HRV was negatively correlated with high density lipoprotein cholesterol levels (r=-0.47, p<0.05), while age and BMI were significantly correlated with TO (r=0.31 and 0.47, respectively; p<0.05 for all). Cardiac autonomic functions were not found to be altered in patients with PCOS in comparison with healthy controls. These results may be explained with the absence of concomitant cardiovascular risk factors with the patients being in the early stage of the disease.

  4. Heart Rate Measures of Flight Test and Evaluation

    National Research Council Canada - National Science Library

    Bonner, Malcolm A; Wilson, Glenn F

    2001-01-01

    .... Because flying is a complex task, several measures are required to derive the best evaluation. This article describes the use of heart rate to augment the typical performance and subjective measures used in test and evaluation...

  5. Single chain Fc-dimer-human growth hormone fusion protein for improved drug delivery.

    Science.gov (United States)

    Zhou, Li; Wang, Hsuan-Yao; Tong, Shanshan; Okamoto, Curtis T; Shen, Wei-Chiang; Zaro, Jennica L

    2017-02-01

    Fc fusion protein technology has been successfully used to generate long-acting forms of several protein therapeutics. In this study, a novel Fc-based drug carrier, single chain Fc-dimer (sc(Fc) 2 ), was designed to contain two Fc domains recombinantly linked via a flexible linker. Since the Fc dimeric structure is maintained through the flexible linker, the hinge region was omitted to further stabilize it against proteolysis and reduce FcγR-related effector functions. The resultant sc(Fc) 2 candidate preserved the neonatal Fc receptor (FcRn) binding. sc(Fc) 2 -mediated delivery was then evaluated using a therapeutic protein with a short plasma half-life, human growth hormone (hGH), as the protein drug cargo. This novel carrier protein showed a prolonged in vivo half-life and increased hGH-mediated bioactivity compared to the traditional Fc-based drug carrier. sc(Fc) 2 technology has the potential to greatly advance and expand the use of Fc-technology for improving the pharmacokinetics and bioactivity of protein therapeutics. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Office and 24-hour heart rate and target organ damage in hypertensive patients

    Directory of Open Access Journals (Sweden)

    García-García Ángel

    2012-03-01

    Full Text Available Abstract Background We investigated the association between heart rate and its variability with the parameters that assess vascular, renal and cardiac target organ damage. Methods A cross-sectional study was performed including a consecutive sample of 360 hypertensive patients without heart rate lowering drugs (aged 56 ± 11 years, 64.2% male. Heart rate (HR and its standard deviation (HRV in clinical and 24-hour ambulatory monitoring were evaluated. Renal damage was assessed by glomerular filtration rate and albumin/creatinine ratio; vascular damage by carotid intima-media thickness and ankle/brachial index; and cardiac damage by the Cornell voltage-duration product and left ventricular mass index. Results There was a positive correlation between ambulatory, but not clinical, heart rate and its standard deviation with glomerular filtration rate, and a negative correlation with carotid intima-media thickness, and night/day ratio of systolic and diastolic blood pressure. There was no correlation with albumin/creatinine ratio, ankle/brachial index, Cornell voltage-duration product or left ventricular mass index. In the multiple linear regression analysis, after adjusting for age, the association of glomerular filtration rate and intima-media thickness with ambulatory heart rate and its standard deviation was lost. According to the logistic regression analysis, the predictors of any target organ damage were age (OR = 1.034 and 1.033 and night/day systolic blood pressure ratio (OR = 1.425 and 1.512. Neither 24 HR nor 24 HRV reached statistical significance. Conclusions High ambulatory heart rate and its variability, but not clinical HR, are associated with decreased carotid intima-media thickness and a higher glomerular filtration rate, although this is lost after adjusting for age. Trial Registration ClinicalTrials.gov: NCT01325064

  7. Effect of Heart rate on Basketball Three-Point Shot Accuracy

    Directory of Open Access Journals (Sweden)

    Luca P. Ardigò

    2018-02-01

    Full Text Available The three-point shot (3S is a fundamental basketball skill used frequently during a game, and is often a main determinant of the final result. The aim of the study was to investigate the effect of different metabolic conditions, in terms of heart rates, on 3S accuracy (3S% in 24 male (Under 17 basketball players (age 16.3 ± 0.6 yrs. 3S performance was specifically investigated at different heart rates. All sessions consisted of 10 consecutive 3Ss from five different significant field spots just beyond the FIBA three-point line, i.e., about 7 m from the basket (two counter-clockwise “laps” at different heart rates: rest (0HR, after warm-up (50%HRMAX [50HR], and heart rate corresponding to 80% of its maximum value (80%HRMAX [80HR]. We found that 50HR does not significantly decrease 3S% (−15%, P = 0.255, while 80HR significantly does when compared to 0HR (−28%, P = 0.007. Given that 50HR does not decrease 3S% compared to 0HR, we believe that no preliminary warm-up is needed before entering a game in order to specifically achieve a high 3S%. Furthermore, 3S training should be performed in conditions of moderate-to-high fatigued state so that a high 3S% can be maintained during game-play.

  8. An open-source LabVIEW application toolkit for phasic heart rate analysis in psychophysiological research.

    Science.gov (United States)

    Duley, Aaron R; Janelle, Christopher M; Coombes, Stephen A

    2004-11-01

    The cardiovascular system has been extensively measured in a variety of research and clinical domains. Despite technological and methodological advances in cardiovascular science, the analysis and evaluation of phasic changes in heart rate persists as a way to assess numerous psychological concomitants. Some researchers, however, have pointed to constraints on data analysis when evaluating cardiac activity indexed by heart rate or heart period. Thus, an off-line application toolkit for heart rate analysis is presented. The program, written with National Instruments' LabVIEW, incorporates a variety of tools for off-line extraction and analysis of heart rate data. Current methods and issues concerning heart rate analysis are highlighted, and how the toolkit provides a flexible environment to ameliorate common problems that typically lead to trial rejection is discussed. Source code for this program may be downloaded from the Psychonomic Society Web archive at www.psychonomic.org/archive/.

  9. Cardiovascular Reactivity and Heart Rate Variability in Panic Disorder

    National Research Council Canada - National Science Library

    Santiago, Helen T

    1999-01-01

    .... Because previous studies of cardiovascular reactivity and heart rate variability have been inconclusive, these factors were re-examined in panickers and controls during physiological challenge...

  10. The effect of orthostatic stress on multiscale entropy of heart rate and blood pressure

    International Nuclear Information System (INIS)

    Turianikova, Zuzana; Javorka, Kamil; Calkovska, Andrea; Javorka, Michal; Baumert, Mathias

    2011-01-01

    Cardiovascular control acts over multiple time scales, which introduces a significant amount of complexity to heart rate and blood pressure time series. Multiscale entropy (MSE) analysis has been developed to quantify the complexity of a time series over multiple time scales. In previous studies, MSE analyses identified impaired cardiovascular control and increased cardiovascular risk in various pathological conditions. Despite the increasing acceptance of the MSE technique in clinical research, information underpinning the involvement of the autonomic nervous system in the MSE of heart rate and blood pressure is lacking. The objective of this study is to investigate the effect of orthostatic challenge on the MSE of heart rate and blood pressure variability (HRV, BPV) and the correlation between MSE (complexity measures) and traditional linear (time and frequency domain) measures. MSE analysis of HRV and BPV was performed in 28 healthy young subjects on 1000 consecutive heart beats in the supine and standing positions. Sample entropy values were assessed on scales of 1–10. We found that MSE of heart rate and blood pressure signals is sensitive to changes in autonomic balance caused by postural change from the supine to the standing position. The effect of orthostatic challenge on heart rate and blood pressure complexity depended on the time scale under investigation. Entropy values did not correlate with the mean values of heart rate and blood pressure and showed only weak correlations with linear HRV and BPV measures. In conclusion, the MSE analysis of heart rate and blood pressure provides a sensitive tool to detect changes in autonomic balance as induced by postural change

  11. Heart Disease Death Rates Among Blacks and Whites Aged ≥35 Years - United States, 1968-2015.

    Science.gov (United States)

    Van Dyke, Miriam; Greer, Sophia; Odom, Erika; Schieb, Linda; Vaughan, Adam; Kramer, Michael; Casper, Michele

    2018-03-30

    Heart disease is the leading cause of death in the United States. In 2015, heart disease accounted for approximately 630,000 deaths, representing one in four deaths in the United States. Although heart disease death rates decreased 68% for the total population from 1968 to 2015, marked disparities in decreases exist by race and state. 1968-2015. The National Vital Statistics System (NVSS) data on deaths in the United States were abstracted for heart disease using diagnosis codes from the eighth, ninth, and tenth revisions of the International Classification of Diseases (ICD-8, ICD-9, and ICD-10) for 1968-2015. Population estimates were obtained from NVSS files. National and state-specific heart disease death rates for the total population and by race for adults aged ≥35 years were calculated for 1968-2015. National and state-specific black-white heart disease mortality ratios also were calculated. Death rates were age standardized to the 2000 U.S. standard population. Joinpoint regression was used to perform time trend analyses. From 1968 to 2015, heart disease death rates decreased for the total U.S. population among adults aged ≥35 years, from 1,034.5 to 327.2 per 100,000 population, respectively, with variations in the magnitude of decreases by race and state. Rates decreased for the total population an average of 2.4% per year, with greater average decreases among whites (2.4% per year) than blacks (2.2% per year). At the national level, heart disease death rates for blacks and whites were similar at the start of the study period (1968) but began to diverge in the late 1970s, when rates for blacks plateaued while rates for whites continued to decrease. Heart disease death rates among blacks remained higher than among whites for the remainder of the study period. Nationwide, the black-white ratio of heart disease death rates increased from 1.04 in 1968 to 1.21 in 2015, with large increases occurring during the 1970s and 1980s followed by small but steady

  12. Effect of Heart rate on Basketball Three-Point Shot Accuracy

    OpenAIRE

    Luca P. Ardigò; Goran Kuvacic; Antonio D. Iacono; Giacomo Dascanio; Johnny Padulo; Johnny Padulo

    2018-01-01

    The three-point shot (3S) is a fundamental basketball skill used frequently during a game, and is often a main determinant of the final result. The aim of the study was to investigate the effect of different metabolic conditions, in terms of heart rates, on 3S accuracy (3S%) in 24 male (Under 17) basketball players (age 16.3 ± 0.6 yrs). 3S performance was specifically investigated at different heart rates. All sessions consisted of 10 consecutive 3Ss from five different significant field spot...

  13. Optimal football strategies: AC Milan versus FC Barcelona

    OpenAIRE

    Papahristodoulou, Christos

    2012-01-01

    In a recent UEFA Champions League game between AC Milan and FC Barcelona, played in Italy (final score 2-3), the collected match statistics, classified into four offensive and two defensive strategies, were in favour of FC Barcelona (by 13 versus 8 points). The aim of this paper is to examine to what extent the optimal game strategies derived from some deterministic, possibilistic, stochastic and fuzzy LP models would improve the payoff of AC Milan at the cost of FC Barcelona.

  14. Spectral analysis of time series of events: effect of respiration on heart rate in neonates

    International Nuclear Information System (INIS)

    Van Drongelen, Wim; Williams, Amber L; Lasky, Robert E

    2009-01-01

    Certain types of biomedical processes such as the heart rate generator can be considered as signals that are sampled by the occurring events, i.e. QRS complexes. This sampling property generates problems for the evaluation of spectral parameters of such signals. First, the irregular occurrence of heart beats creates an unevenly sampled data set which must either be pre-processed (e.g. by using trace binning or interpolation) prior to spectral analysis, or analyzed with specialized methods (e.g. Lomb's algorithm). Second, the average occurrence of events determines the Nyquist limit for the sampled time series. Here we evaluate different types of spectral analysis of recordings of neonatal heart rate. Coupling between respiration and heart rate and the detection of heart rate itself are emphasized. We examine both standard and data adaptive frequency bands of heart rate signals generated by models of coupled oscillators and recorded data sets from neonates. We find that an important spectral artifact occurs due to a mirror effect around the Nyquist limit of half the average heart rate. Further we conclude that the presence of respiratory coupling can only be detected under low noise conditions and if a data-adaptive respiratory band is used

  15. Heart rate-based lactate minimum test: a reproducible method.

    NARCIS (Netherlands)

    Strupler, M.; Muller, G.; Perret, C.

    2009-01-01

    OBJECTIVE: To find the individual intensity for aerobic endurance training, the lactate minimum test (LMT) seems to be a promising method. LMTs described in the literature consist of speed or work rate-based protocols, but for training prescription in daily practice mostly heart rate is used. The

  16. Heart rate variability analysis in healthy subjects, patients suffering from congestive heart failure and heart transplanted patients

    Directory of Open Access Journals (Sweden)

    Argentina Leite

    2013-12-01

    Full Text Available This study aimed to find parameters to characterize heart rate variability (HRV and discriminate healthy subjects and patients with heart diseases. The parameters used for discrimination characterize the different components of HRV memory (short and long and are extracted from HRV recordings using parametric as well as non parametric methods. Thus, the parameters are: spectral components at low frequencies (LH and high frequencies (HF which are associated with the short memory of HRV and the long memory parameter (d obtained from autoregressive fractionally integrated moving average (ARFIMA models. In the non parametric context, short memory (α1 and long memory (α2 parameters are obtained from detrended fluctuation analysis (DFA. The sample used in this study contains 24-hour Holter HRV recordings of 30 subjects: 10 healthy individuals, 10 patients suffering from congestive heart failure and 10 heart transplanted patients from the Noltisalis database. It was found that short memory parameters present higher values for the healthy individuals whereas long memory parameters present higher values for the diseased individuals. Moreover, there is evidence that ARFIMA modeling allows the discrimination between the 3 groups under study, being advantageous over DFA.

  17. Effect of atrioventricular conduction on heart rate variability

    KAUST Repository

    Ahmad, Talha Jamal; Ali, Hussnain; Majeed, S. M Imran; Khan, Shoab A.

    2011-01-01

    This paper discusses the effect of atrioventricular conduction time (AVCT) on the short-term Heart Rate Variability (HRV) by computing HRV parameters using intervals between the onsets of successive P waves (PP time series) for three groups: normal

  18. Hopfield neural network and optical fiber sensor as intelligent heart rate monitor

    Science.gov (United States)

    Mutter, Kussay Nugamesh

    2018-01-01

    This paper presents a design and fabrication of an intelligent fiber-optic sensor used for examining and monitoring heart rate activity. It is found in the literature that the use of fiber sensors as heart rate sensor is widely studied. However, the use of smart sensors based on Hopfield neural networks is very low. In this work, the sensor is a three fibers without cladding of about 1 cm, fed by laser light of 1550 nm of wavelength. The sensing portions are mounted with a micro sensitive diaphragm to transfer the pulse pressure on the left radial wrist. The influenced light intensity will be detected by a three photodetectors as inputs into the Hopfield neural network algorithm. The latter is a singlelayer auto-associative memory structure with a same input and output layers. The prior training weights are stored in the net memory for the standard recorded normal heart rate signals. The sensors' heads work on the reflection intensity basis. The novelty here is that the sensor uses a pulse pressure and Hopfield neural network in an integrity approach. The results showed a significant output measurements of heart rate and counting with a plausible error rate.

  19. Variation in heart rate influences the assessment of transient ischemic dilation in myocardial perfusion scintigraphy

    International Nuclear Information System (INIS)

    Leslie, William D; Levin, Daniel P; Demeter, Sandor J

    2007-01-01

    Transient arrhythmias can affect transient ischemic dilation (TID) ratios. This study was initiated to evaluate the frequency and effect of normal heart rate change on TID measures in routine clinical practice. Consecutive patients undergoing stress/rest sestamibi gated myocardial perfusion scintigraphy were studied (N = 407). Heart rate at the time of stress and rest imaging were recorded. TID ratios were analyzed in relation to absolute change in heart rate (stress minus rest) for subjects with normal perfusion and systolic function (Group 1, N = 169) and those with abnormalities in perfusion and/or function (Group 2, N = 238). In Group 1, mean TID ratio was inversely correlated with the change in heart rate (r = -0.47, P < 0.0001). For every increase of 10 BPM in heart rate change, the TID ratio decreased by approximately 0.06 (95% confidence interval 0.04–0.07). In Group 2, multiple linear regression demonstrated that the change in heart rate (beta = -0.25, P < 0.0001) and the summed difference score (beta = 0.36, P < 0.0001) were independent predictors of the TID ratio. Normal variation in heart rate between the stress and rest components of myocardial perfusion scans is common and can influence TID ratios in patients with normal and abnormal cardiac scans

  20. gHRV: Heart rate variability analysis made easy.

    Science.gov (United States)

    Rodríguez-Liñares, L; Lado, M J; Vila, X A; Méndez, A J; Cuesta, P

    2014-08-01

    In this paper, the gHRV software tool is presented. It is a simple, free and portable tool developed in python for analysing heart rate variability. It includes a graphical user interface and it can import files in multiple formats, analyse time intervals in the signal, test statistical significance and export the results. This paper also contains, as an example of use, a clinical analysis performed with the gHRV tool, namely to determine whether the heart rate variability indexes change across different stages of sleep. Results from tests completed by researchers who have tried gHRV are also explained: in general the application was positively valued and results reflect a high level of satisfaction. gHRV is in continuous development and new versions will include suggestions made by testers. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  1. Using a smartphone to measure heart rate changes during relived happiness and anger

    NARCIS (Netherlands)

    Lakens, D.

    2013-01-01

    This study demonstrates the feasibility of measuring heart rate differences associated with emotional states such as anger and happiness with a smartphone. Novice experimenters measured higher heart rates during relived anger and happiness (replicating findings in the literature) outside a

  2. Automatic heart rate normalization for accurate energy expenditure normalization : an analysis of activities of daily living and heart rate features

    NARCIS (Netherlands)

    Altini, M.; Penders, J.; Vullers, R.J.M.; Amft, O.D.

    2014-01-01

    Introduction: This article is part of the Focus Theme of Methods of Information in Medicine on "Pervasive Intelligent Technologies for Health". Background: Energy Expenditure (EE) estimation algorithms using Heart Rate (HR) or a combination of accelerometer and HR data suffer from large error due to

  3. Effect of the Torrance Creative Thinking Test on Heart Rate Signal Features

    Directory of Open Access Journals (Sweden)

    Zakeri S.

    2016-02-01

    Full Text Available Aims: Showing a meta-cognitive aspect, creativity is related to higher mental processes such as thinking, intelligence, imagination, and information process. There are many studies on the physiological bases of creativity. The aim of this study was to investigate the effects of creative thinking on the heart rate signal. Materials & Methods: In this semi-experimental study, 52 medical engineering, electrical, and control students of Sahand University were studied in 2012. The subjects were selected via accessible sampling method. To assess the level of the students’ creative thinking, Torrance Tests of Creative Thinking (B form; figural was used. Before and during creative thinking test, heart signal in the rest position was recorded by 1000Hz sampling frequency. Data was analyzed using Wilcoxon non-parametric test.   Findings: There was an increase in the mean heart power amplitude during creative thinking than the rest position. However, passing time and conducting the last sessions of the creativity test, it showed a reduction. There was an increase in the heart rate in persons with high creativity than those with low creativity. In addition, based on the test scores, there was a higher creativity level in females and three-lingual persons than males and bi-lingual persons, respectively. There was an increase in the heart rate in females than males (p=0.0398. Nevertheless, there was no significant difference between three-lingual and bilingual persons (p>0.05.    Conclusion: Creative thinking results in an increase in the heart rate in persons with high creativity than persons with low creativity. Therefore, the creativity level can be detected via heart signal. 

  4. Heart rate variability in normal-weight patients with polycystic ovary syndrome

    OpenAIRE

    Kilit, Celal; Kilit, T?rkan Pa?al?

    2017-01-01

    Objective: Polycystic ovary syndrome (PCOS) is an endocrine disease closely related to several risk factors of cardiovascular disease. Obese women with PCOS show altered autonomic modulation. The results of studies investigating cardiac autonomic functions of normal-weight women with PCOS are conflicting. The aim of the study was to assess the reactivity of cardiac sympathovagal balance in normal-weight women with PCOS by heart rate variability analysis. Methods: We examined the heart rate va...

  5. Multiple Plasmodium falciparum erythrocyte membrane protein 1 variants per genome can bind IgM via its Fc fragment Fcμ

    DEFF Research Database (Denmark)

    Jeppesen, Anine; Ditlev, Sisse Bolm; Soroka, Vladyslav

    2015-01-01

    with severe clinical manifestations, such as cerebral malaria in children and placental malaria in pregnant women. PfEMP1 that can bind the Fc part of IgM (Fcμ) characterizes one such type, although the functional significance of this IgM binding to PfEMP1 remains unclear. In this study, we report...... resemble the rosette-mediating and IgM-binding PfEMP1 HB3VAR06, but none of them mediated formation of rosettes. We could map the capacity for Fc-specific IgM binding to DBLε domains near the C terminus for three of the four PfEMP1 proteins tested. Our study provides new evidence regarding Fc...

  6. Early warnings of heart rate deterioration

    OpenAIRE

    Almeida, Vânia G.; Nabney, Ian T.

    2016-01-01

    Hospitals can experience difficulty in detecting and responding to early signs of patient deterioration leading to late intensive care referrals, excess mortality and morbidity, and increased hospital costs. Our study aims to explore potential indicators of physiological deterioration by the analysis of vital-signs. The dataset used comprises heart rate (HR) measurements from MIMIC II waveform database, taken from six patients admitted to the Intensive Care Unit (ICU) and diagnosed with sever...

  7. Continuous measurement of heart rate variability following carbon ...

    African Journals Online (AJOL)

    Background: Previous studies of autonomic nervous system activity through analysis of heart rate variability (HRV) have demonstrated increased sympathetic activity during positive-pressure pneumoperitoneum. We employed an online, continuous method for rapid HRV analysis (MemCalc™, Tarawa, Suwa Trust, Tokyo, ...

  8. Endogenous Pain Modulation: Association with Resting Heart Rate Variability and Negative Affectivity.

    Science.gov (United States)

    Van Den Houte, Maaike; Van Oudenhove, Lukas; Bogaerts, Katleen; Van Diest, Ilse; Van den Bergh, Omer

    2017-07-21

    Several chronic pain syndromes are characterized by deficient endogenous pain modulation as well as elevated negative affectivity and reduced resting heart rate variability. In order to elucidate the relationships between these characteristics, we investigated whether negative affectivity and heart rate variability are associated with endogenous pain modulation in a healthy population. An offset analgesia paradigm with noxious thermal stimulation calibrated to the individual's pain threshold was used to measure endogenous pain modulation magnitude in 63 healthy individuals. Pain ratings during constant noxious heat stimulation to the arm (15 seconds) were compared with ratings during noxious stimulation comprising a 1 °C rise and return of temperature to the initial level (offset trials, 15 seconds). Offset analgesia was defined as the reduction in pain following the 1 °C decrease relative to pain at the same time point during continuous heat stimulation. Evidence for an offset analgesia effect could only be found when noxious stimulation intensity (and, hence, the individual's pain threshold) was intermediate (46 °C or 47 °C). Offset analgesia magnitude was also moderated by resting heart rate variability: a small but significant offset effect was found in participants with high but not low heart rate variability. Negative affectivity was not related to offset analgesia magnitude. These results indicate that resting heart rate variability (HRV) is related to endogenous pain modulation (EPM) in a healthy population. Future research should focus on clarifying the causal relationship between HRV and EPM and chronic pain by using longitudinal study designs. © 2017 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  9. Incident solar radiation and coronary heart disease mortality rates in Europe

    International Nuclear Information System (INIS)

    Wong, Alfred

    2008-01-01

    The reported low mortality rate from coronary heart disease in Portugal, Spain, Italy, Greece, and France, to a lesser extent, has been attributed in numerous nutritional studies to the consumption of a Mediterranean-type diet. There are still many unresolved issues about the direct causal effect of the Mediterranean dietary regime on low incidence of coronary heart disease. An analysis of coronary heart disease mortality rates in Europe from a latitudinal gradient perspective has shown to have a close correlation to incident solar radiation. It is surmised that the resulting increased in situ biosynthesis of Vitamin D 3 could be the critical missing confounder in the analysis of the beneficial health outcome of the Mediterranean diet

  10. Effect of pre operative heart rate on post spinal hypotension in obsteric patients

    International Nuclear Information System (INIS)

    Khan, S.; Zahoor, M.U.; Zaid, A.Y.; Buland, K.

    2010-01-01

    The purpose of the study was to determine the association between of preoperative heart rate and post spinal hypotension in women undergoing cesarean section, Two hundred patients undergoing caesarean were included in the study selected on non probability convenience sampling technique, The patients were divided into two groups depending upon their pre operative heart rate. Spinal anesthesia was administered and number of patients developing hypotension was noted. Among 200 patients, who were included in the study; 112 were placed in group A and 88 were placed in group B depending on mean heart rate of 90 beats per minute or less or 91 beats per minute or more respectively. In group A 14 (11.86%) patients developed hypotension where as in group B 28 (31,82%) patients developed hypotension. Pre operative heart rate is significantly associated with post spinal hypotension in obstetric patients undergoing cesarean section. (author)

  11. Design of a heart rate controller for treadmill exercise using a recurrent fuzzy neural network.

    Science.gov (United States)

    Lu, Chun-Hao; Wang, Wei-Cheng; Tai, Cheng-Chi; Chen, Tien-Chi

    2016-05-01

    In this study, we developed a computer controlled treadmill system using a recurrent fuzzy neural network heart rate controller (RFNNHRC). Treadmill speeds and inclines were controlled by corresponding control servo motors. The RFNNHRC was used to generate the control signals to automatically control treadmill speed and incline to minimize the user heart rate deviations from a preset profile. The RFNNHRC combines a fuzzy reasoning capability to accommodate uncertain information and an artificial recurrent neural network learning process that corrects for treadmill system nonlinearities and uncertainties. Treadmill speeds and inclines are controlled by the RFNNHRC to achieve minimal heart rate deviation from a pre-set profile using adjustable parameters and an on-line learning algorithm that provides robust performance against parameter variations. The on-line learning algorithm of RFNNHRC was developed and implemented using a dsPIC 30F4011 DSP. Application of the proposed control scheme to heart rate responses of runners resulted in smaller fluctuations than those produced by using proportional integra control, and treadmill speeds and inclines were smoother. The present experiments demonstrate improved heart rate tracking performance with the proposed control scheme. The RFNNHRC scheme with adjustable parameters and an on-line learning algorithm was applied to a computer controlled treadmill system with heart rate control during treadmill exercise. Novel RFNNHRC structure and controller stability analyses were introduced. The RFNNHRC were tuned using a Lyapunov function to ensure system stability. The superior heart rate control with the proposed RFNNHRC scheme was demonstrated with various pre-set heart rates. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  12. Fc-mediated immune precipitation. III. Visualization by electron microscopy

    DEFF Research Database (Denmark)

    Møller, NPH; Christiansen, Gunna

    1983-01-01

    with either rabbit anti-KLH IgG or anti-KLH F(ab')2 fragments. The Fc-Fc interactions were investigated by reacting these surface-adsorbed antibody-rich KLH immune complexes with soluble, antigen-rich ferritin-anti-ferritin complexes using either rabbit anti-ferritin IgG or the corresponding isomolar F(ab')2...... fragments as antibody. Fc-Fc interactions were indicated by the formation of clusters or ring structures of ferritin molecules, which were only seen when using KLH anti-KLH IgG and ferritin-anti-ferritin IgG complexes. When F(ab')2 fragments were used as antibody, no reaction between KLH anti-KLH complexes...

  13. Activity and heart rate in semi-domesticated reindeer during adaptation to emergency feeding.

    Science.gov (United States)

    Nilsson, A; Ahman, B; Norberg, H; Redbo, I; Eloranta, E; Olsson, K

    2006-06-15

    Although reindeer are well adapted to limited food resources during winter, semi-domesticated reindeer are regularly fed when snow conditions are bad in order to prevent starvation. Feeding sometimes results in health problems and loss of animals. This study was made to assess if activity pattern in reindeer could be used as a tool for the reindeer herder in early detection of animals that are not adapting to feeding. The frequency of 10 behavioural categories was recorded in five groups of penned, eight-month-old, female semi-domesticated reindeer. Three reindeer per group were fitted with heart rate monitors. Lying was the most frequent behaviour, whilst there were few cases of agonistic behaviour. Heart rate varied during the day, with peaks during feeding and low heart rates in the early morning. Restricted feed intake resulted in more locomotion and seeking but less ruminating compared to feeding ad libitum. This was followed by a generally lower heart rate in reindeer in the restricted groups compared to controls. Subsequent feeding with different combinations of lichens, silage and pellets ad libitum resulted initially in significantly more of the animals lying curled up, compared to controls, combined with increased heart rates. As the experiment continued the general activity pattern, as well as the heart rate, gradually became more similar in all groups. Lying curled was the behavioural indicator most consistently affected by feed deprivation and adaptation to feeding and may thus be a useful indicator to distinguish individual reindeer that are not adjusting to feeding.

  14. Changes in heart rate associated with contest outcome in agonistic encounters in lobsters.

    Science.gov (United States)

    Hernáindez-Falcón, Jesús; Basu, Alo C; Govindasamy, Siddhartan; Kravitz, Edward A

    2005-03-01

    Agonistic contests between lobsters housed together in a confined space progress through encounters of increasing intensity until a dominance relationship is established. Once this relationship is established, losing animals continually retreat from the advances of winners. These encounters are likely to consume much energy in both winning and losing animals. Therefore, one might expect involvement of many physiological systems before, during and after fights. Here, we report effects of agonistic encounters on cardiac frequency in winning and losing adult lobsters involved in dyadic interactions. The results show that: (i) small but significant increases in heart rate are observed upon chemical detection of a conspecific; (ii) during agonistic interactions, further increases in heart rate are seen; and (iii) ultimate winners exhibit greater increases in heart rate lasting longer periods of time compared to ultimate losers. Heart rate in winners remains elevated for at least 15 min after the contests have ended and animals have been returned to their home tanks. Reduced effects are seen in second and third pairings between familiar opponents. The sustained changes in heart rate that we observe in winning lobsters may result from hormonal modulation of cardiac function related to the change in social status brought about by contest outcome.

  15. Comparative evaluation of heart rate-based monitors: Apple Watch vs Fitbit Charge HR.

    Science.gov (United States)

    Bai, Yang; Hibbing, Paul; Mantis, Constantine; Welk, Gregory J

    2018-08-01

    The purpose of this investigation was to examine the validity of energy expenditure (EE), steps, and heart rate measured with the Apple Watch 1 and Fitbit Charge HR. Thirty-nine healthy adults wore the two monitors while completing a semi-structured activity protocol consisting of 20 minutes of sedentary activity, 25 minutes of aerobic exercise, and 25 minutes of light intensity physical activity. Criterion measures were obtained from an Oxycon Mobile for EE, a pedometer for steps, and a Polar heart rate strap worn on the chest for heart rate. For estimating whole-trial EE, the mean absolute percent error (MAPE) from Fitbit Charge HR (32.9%) was more than twice that of Apple Watch 1 (15.2%). This trend was consistent for the individual conditions. Both monitors accurately assessed steps during aerobic activity (MAPE Apple : 6.2%; MAPE Fitbit : 9.4%) but overestimated steps in light physical activity. For heart rate, Fitbit Charge HR produced its smallest MAPE in sedentary behaviors (7.2%), followed by aerobic exercise (8.4%), and light activity (10.1%). The Apple Watch 1 had stronger validity than the Fitbit Charge HR for assessing overall EE and steps during aerobic exercise. The Fitbit Charge HR provided heart rate estimates that were statistically equivalent to Polar monitor.

  16. Embryos in the fast lane: high-temperature heart rates of turtles decline after hatching.

    Directory of Open Access Journals (Sweden)

    Wei-Guo Du

    Full Text Available In ectotherms such as turtles, the relationship between cardiovascular function and temperature may be subject to different selective pressures in different life-history stages. Because embryos benefit by developing as rapidly as possible, and can "afford" to expend energy to do so (because they have access to the yolk for nutrition, they benefit from rapid heart (and thus, developmental rates. In contrast, hatchlings do not have a guaranteed food supply, and maximal growth rates may not enhance fitness--and so, we might expect a lower heart rate, especially at high temperatures where metabolic costs are greatest. Our data on two species of emydid turtles, Chrysemys picta, and Graptemys pseudogeographica kohnii, support these predictions. Heart rates of embryos and hatchlings were similar at low temperatures, but heart rates at higher temperatures were much greater before than after hatching.

  17. Continuous measurement of heart rate variability following carbon ...

    African Journals Online (AJOL)

    2010-07-16

    Jul 16, 2010 ... Power spectral analysis of the electrocardiographic R-R interval [heart rate variability: (HRV)] is a well known, non- invasive method for assessing autonomic nervous activity.1. Studies using HRV analysis during positive-pressure pneumoperitoneum (PPP) have demonstrated increased sympathetic ...

  18. Universal design of a microcontroller and IoT system to detect the heart rate

    Science.gov (United States)

    Uwamahoro, Raphael; Mushikiwabeza, Alexie; Minani, Gerard; Mohan Murari, Bhaskar

    2017-11-01

    Heart rate analysis provides vital information of the present condition of the human body. It helps medical professionals in diagnosis of various malfunctions of the body. The limitation of vision impaired and blind people to access medical devices cause a considerable loss of life. In this paper, we intended to develop a heart rate detection system that is usable for people with normal and abnormal vision. The system is based on a non-invasive method of measuring the variation of the tissue blood flow rate by means of a photo transmitter and detector through fingertip known as photoplethysmography (PPG). The signal detected is firstly passed through active low pass filter and then amplified by a two stages high gain amplifier. The amplified signal is feed into the microcontroller to calculate the heart rate and displays the heart beat via sound systems and Liquid Crystal Display (LCD). To distinguish arrhythmia, normal heart rate and abnormal working conditions of the system, recognition is provided in different sounds, LCD readings and Light Emitting Diodes (LED).

  19. Lack of evidence for low-dimensional chaos in heart rate variability

    DEFF Research Database (Denmark)

    Kanters, J K; Holstein-Rathlou, N H; Agner, E

    1994-01-01

    INTRODUCTION: The term chaos is used to describe erratic or apparently random time-dependent behavior in deterministic systems. It has been suggested that the variability observed in the normal heart rate may be due to chaos, but this question has not been settled. METHODS AND RESULTS: Heart rate...... in the experimental data, but the prediction error as a function of the prediction length increased at a slower rate than characteristic of a low-dimensional chaotic system. CONCLUSION: There is no evidence for low-dimensional chaos in the time series of RR intervals from healthy human subjects. However, nonlinear...

  20. Visualization of heart rate variability of long-term heart transplant patient by transition networks: a case report

    Directory of Open Access Journals (Sweden)

    Joanna eWdowczyk

    2016-03-01

    Full Text Available We present a heart transplant patient at his 17th year of uncomplicated follow-up. Within a frame of routine check out several tests were performed. With such a long and uneventful follow-up some degree of graft reinnervation could be anticipated. However, the patient's electrocardiogram and exercise parameters seemed largely inconclusive in this regard. The exercise heart rate dynamics were suggestive of only mild, if any parasympathetic reinnervation of the graft with persisting sympathetic activation. On the other hand, traditional heart rate variability (HRV indices were inadequately high, due to erratic rhythm resulting from interference of the persisting recipient sinus node or nonconducted atrial parasystole. New tools, originated from network representation of time series, by visualization short-term dynamical patterns, provided a method to discern HRV increase due to reinnervation from other reasons.

  1. General anesthesia suppresses normal heart rate variability in humans

    Science.gov (United States)

    Matchett, Gerald; Wood, Philip

    2014-06-01

    The human heart normally exhibits robust beat-to-beat heart rate variability (HRV). The loss of this variability is associated with pathology, including disease states such as congestive heart failure (CHF). The effect of general anesthesia on intrinsic HRV is unknown. In this prospective, observational study we enrolled 100 human subjects having elective major surgical procedures under general anesthesia. We recorded continuous heart rate data via continuous electrocardiogram before, during, and after anesthesia, and we assessed HRV of the R-R intervals. We assessed HRV using several common metrics including Detrended Fluctuation Analysis (DFA), Multifractal Analysis, and Multiscale Entropy Analysis. Each of these analyses was done in each of the four clinical phases for each study subject over the course of 24 h: Before anesthesia, during anesthesia, early recovery, and late recovery. On average, we observed a loss of variability on the aforementioned metrics that appeared to correspond to the state of general anesthesia. Following the conclusion of anesthesia, most study subjects appeared to regain their normal HRV, although this did not occur immediately. The resumption of normal HRV was especially delayed on DFA. Qualitatively, the reduction in HRV under anesthesia appears similar to the reduction in HRV observed in CHF. These observations will need to be validated in future studies, and the broader clinical implications of these observations, if any, are unknown.

  2. Analyses of Heart Rate, Respiration and Cardiorespiratory Coupling in Patients with Schizophrenia

    Directory of Open Access Journals (Sweden)

    Steffen Schulz

    2015-01-01

    Full Text Available Schizophrenia is a severe mental disorder associated with a significantly increased cardiovascular mortality rate. However, the underlying mechanisms leading to this cardiovascular disease (CVD are not fully known. Therefore, the objective of this study was to characterize the cardiorespiratory influence by investigating heart rate, respiration and the causal strength and direction of cardiorespiratory coupling (CRC, based mainly on entropy measures. We investigated 23 non-medicated patients with schizophrenia (SZ, comparing them to 23 age- and gender-matched healthy controls (CO. A significantly reduced complexity was found for the heart rate and a significantly increased complexity in respiration and CRC in SZ patients when compared to corresponding measurements from CO (p < 0.001. CRC analyses revealed a clear coupling, with a driver-responder relationship from respiration to heart rate in SZ patients. Moreover, a slight driver-responder relationship from heart rate to respiration could be recognized. These findings lead to the assumption that SZ should be considered to be a high-risk group for CVD. We hypothesize that the varying cardiorespiratory regulation contributes to the increased risk for cardiac mortality. Therefore, regular monitoring of the cardiorespiratory status of SZ is suggested to identify autonomic regulation impairment at an early stage—to develop timely and effective treatment and intervention strategies.

  3. Human IgG4 binds to IgG4 and conformationally altered IgG1 via Fc-Fc interactions

    NARCIS (Netherlands)

    Rispens, Theo; Ooievaar-de Heer, Pleuni; Vermeulen, Ellen; Schuurman, Janine; van der Neut Kolfschoten, Marijn; Aalberse, Rob C.

    2009-01-01

    The Fc fragment of IgG4 can interact with the Fc fragment of another IgG molecule. This interaction is a confounding factor when measuring IgG4 rheumatoid factor levels. Recently, we demonstrated that half-molecules of IgG4 can exchange to form a bispecific Ab. We expected these two phenomena to be

  4. Nonlinear analysis of heart rate variability in patients with eating disorders

    NARCIS (Netherlands)

    Vigo, Daniel E.; Castro, Mariana N.; Dorpinghaus, Andrea; Weidema, Hylke; Cardinali, Daniel P.; Siri, Leonardo Nicola; Rovira, Bernardo; Fahrer, Rodolfo D.; Nogues, Martin; Leiguarda, Ramon C.; Guinjoan, Salvador M.

    2008-01-01

    Patients with anorexia nervosa or bulimia nervosa often have signs of autonomic dysfunction potentially deleterious to the heart. The aim of this study was to ascertain the nonlinear properties of heart rate variability in patients with eating disorders. A group of 33 women with eating disorders (14

  5. Evaluation of sympathetic nerve system activity with MIBG. Comparison with heart rate variability

    International Nuclear Information System (INIS)

    Kurata, Chinori; Wakabayashi, Yasushi; Shouda, Sakae; Mikami, Tadashi; Tawarahara, Kei; Sugiyama, Tsuyoshi; Nakano, Tomoyasu; Suzuki, Toshihiko.

    1997-01-01

    Authors attempted to elucidate the relations of plasma concentration of norepinephrine (pNE) and findings of heart rate variability and MIBG myocardial scintigraphy and evaluated cardiac autonomic nervous activity in chronic renal failure. Subjects were 211 patients with various heart diseases (coronary artery lesion, cardiomyopathy, hypertension, diabetes mellitus, renal failure and so on), 60 patients with artificial kidney due to chronic renal failure, 13 of whom were found to have coronary arterial disease by Tl myocardial scintigraphy, and 14 normal volunteers. ECG was recorded with the portable recorder for heart rate variability. Together with collection of blood for pNE measurement, myocardial scintigraphy was done at 15 and 150 min after intravenous administration of 111 MBq of MIBG for acquisition of early and delayed, respectively, images of the frontal breast. Accumulation at and elimination during the time points of MIBG were computed in cps unit. Variability of heart rate was found to have the correlation positive with MIBG delayed accumulation and negative with the elimination, and pNE, negative with heart rate variability and the delayed accumulation and positive with the elimination. Thus cardiac autonomic nervous abnormality was suggested to occur before uremic cardiomyopathy. (K.H.)

  6. Modulating Cytotoxic Effector Functions by Fc Engineering to Improve Cancer Therapy.

    Science.gov (United States)

    Kellner, Christian; Otte, Anna; Cappuzzello, Elisa; Klausz, Katja; Peipp, Matthias

    2017-09-01

    In the last two decades, monoclonal antibodies have revolutionized the therapy of cancer patients. Although antibody therapy has continuously been improved, still a significant number of patients do not benefit from antibody therapy. Therefore, rational optimization of the antibody molecule by Fc engineering represents a major area of translational research to further improve this potent therapeutic option. Monoclonal antibodies are able to trigger a variety of effector mechanisms. Especially Fc-mediated effector functions such as antibody-dependent cell-mediated cytotoxicity (ADCC), antibody-dependent cellular phagocytosis (ADCP), and complement- dependent cytotoxicity (CDC) are considered important in antibody therapy of cancer. Novel mechanistic insights into the action of monoclonal antibodies allowed the development of various Fc engineering approaches to modulate antibodies' effector functions. Strategies in modifying the Fc glycosylation profile (Fc glyco-engineering) or approaches in engineering the protein backbone (Fc protein engineering) have been intensively evaluated. In the current review, Fc engineering strategies resulting in improved ADCC, ADCP and CDC activity are summarized and discussed.

  7. Glutamate transporter type 3 knockout leads to decreased heart rate possibly via parasympathetic mechanism

    OpenAIRE

    Deng, Jiao; Li, Jiejie; Li, Liaoliao; Feng, Chenzhuo; Xiong, Lize; Zuo, Zhiyi

    2013-01-01

    Parasympathetic tone is a dominant neural regulator for basal heart rate. Glutamate transporters (EAAT) via their glutamate uptake functions regulate glutamate neurotransmission in the central nervous system. We showed that EAAT type 3 (EAAT3) knockout mice had a slower heart rate than wild-type mice when they were anesthetized. We design this study to determine whether non-anesthetized EAAT3 knockout mice have a slower heart rate and, if so, what may be the mechanism for this effect. Young a...

  8. Heart Rate Changes in Electroacupuncture Treated Polycystic Ovary in Rats.

    Science.gov (United States)

    Ramadoss, Mukilan; Ramanathan, Gunasekaran; Subbiah, Angelie Jessica; Natrajan, Chidambaranathan

    2016-03-01

    Polycystic Ovary Syndrome (PCOS) is a common metabolic disorder, it affects both humans and animals. It may induce coronary heart disease, obesity and hyperandrogenism. Previous studies show that Low frequency Electroacupuncture (EA) have an effect on PCOS, however the exact pathway is unclear. To find the effect of EA on autonomic activity of the heart in Estradiol Valerate (EV) induced PCOS rats. Heart rate variability (HRV) was assessed in 3 groups: 1) Control; 2) PCOS rats; and 3) PCOS rats after EA treatment (n=8 in each group). From the time domain analysis and frequency domain analysis (linear measures) HRV analysis was done. EA stimulation was given at low frequency of 2Hz for 15 min on alternate days for 4-5 weeks. Collected data were statistically analysed using One-Way Analysis of Variance with the application of multiple comparisons of Tukey test. EA treatment group shows significant reduction in Heart Rate (HR) and low frequency, high frequency ratio (LF/HF); and increase in RR interval, Total Power (TP) when compared to PCOS group. The study concludes that EA treatment has a significant effect on reducing sympathetic tone and decreasing HR in PCOS.

  9. Heart Rate, Stress, and Occupational Noise Exposure among Electronic Waste Recycling Workers

    Directory of Open Access Journals (Sweden)

    Katrina N. Burns

    2016-01-01

    Full Text Available Electronic waste (e-waste is a growing occupational and environmental health issue around the globe. E-waste recycling is a green industry of emerging importance, especially in low-and middle-income countries where much of this recycling work is performed, and where many people’s livelihoods depend on this work. The occupational health hazards of e-waste recycling have not been adequately explored. We performed a cross-sectional study of noise exposures, heart rate, and perceived stress among e-waste recycling workers at a large e-waste site in Accra, Ghana. We interviewed 57 workers and continuously monitored their individual noise exposures and heart rates for up to 24 h. More than 40% of workers had noise exposures that exceeded recommended occupational (85 dBA and community (70 dBA noise exposure limits, and self-reported hearing difficulties were common. Workers also had moderate to high levels of perceived stress as measured via Cohen’s Perceived Stress Scale, and reported a variety of symptoms that could indicate cardiovascular disease. Noise exposures were moderately and significantly correlated with heart rate (Spearman’s ρ 0.46, p < 0.001. A mixed effects linear regression model indicated that a 1 dB increase in noise exposure was associated with a 0.17 increase in heart rate (p-value = 0.01 even after controlling for work activities, age, smoking, perceived stress, and unfavorable physical working conditions. These findings suggest that occupational and non-occupational noise exposure is associated with elevations in average heart rate, which may in turn predict potential cardiovascular damage.

  10. Combinatorial effect of nicotine and black tea on heart rate variability: Useful or harmful?

    Science.gov (United States)

    Joukar, S; Sheibani, M

    2017-06-01

    The effect of nicotine on heart rate variability (HRV) is controversial. Autonomic nervous system is the main regulator of heart rhythm, and heart rate variability is an appropriate index to assessment of the effects of the autonomic system on heart. In this study, the combination effect of nicotine and black tea consumption on sympatho-vagal balance and heart rate variability was investigated in rats. Male Wistar rats were randomized into four groups as control, tea (2.5 g/100 cc, daily), nicotine (2 mg/kg/d) and tea plus nicotine groups which treated for 28 days, and in the 29th day, their electrocardiograms (lead II) were recorded. The mean of high-frequency power (HF) in tea, nicotine and tea plus nicotine groups was significantly more than control group (P nicotine and tea + nicotine groups was significantly less than control group (P nicotine and tea + nicotine groups in comparison with control group (P nicotine or their combination with dosages used in this study can increase the heart rate variability and improve the sympatho-vagal balance in rat. © 2017 John Wiley & Sons Ltd.

  11. Effect of partial sports massage on blood pressure and heart rate

    Directory of Open Access Journals (Sweden)

    T.D. Pystupa

    2013-12-01

    Full Text Available With the growing popularity and demand for different types of massages (including sports is a growing need for research on specific forms. There is also a need to study the advantages and effects on various body functions. The objective was to study the effect of partial sports massage on blood pressure and heart rate in both men and women. Material and methods. Research has been extended 80 healthy men and women are physically active (age 20-25 years. Blood pressure and heart rate were made on the left arm automatic digital device (model HEM - 907. The device is intended to measure blood pressure. It is established that it is possible to verify the existing beliefs. This promotes more efficient use of massage therapy. Conclusions . Sports massage has an effect on hemodynamic changes, the increase (decrease in blood pressure acceleration (deceleration of the heart rate. It depends on what part of the body exposed to the massage procedure.

  12. GLP-1 receptor stimulation depresses heart rate variability and inhibits neurotransmission to cardiac vagal neurons.

    Science.gov (United States)

    Griffioen, Kathleen J; Wan, Ruiqian; Okun, Eitan; Wang, Xin; Lovett-Barr, Mary Rachael; Li, Yazhou; Mughal, Mohamed R; Mendelowitz, David; Mattson, Mark P

    2011-01-01

    glucagon-like peptide 1 (GLP-1) is an incretin hormone released from the gut in response to food intake. Whereas GLP-1 acts in the periphery to inhibit glucagon secretion and stimulate insulin release, it also acts in the central nervous system to mediate autonomic control of feeding, body temperature, and cardiovascular function. Because of its role as an incretin hormone, GLP-1 receptor analogs are used as a treatment for type 2 diabetes. Central or peripheral administration of GLP-1 increases blood pressure and heart rate, possibly by activating brainstem autonomic nuclei and increasing vagus nerve activity. However, the mechanism(s) by which GLP-1 receptor stimulation affects cardiovascular function are unknown. We used the long-lasting GLP-1 receptor agonist Exendin-4 (Ex-4) to test the hypothesis that GLP-1 signalling modulates central parasympathetic control of heart rate. using a telemetry system, we assessed heart rate in mice during central Ex-4 administration. Heart rate was increased by both acute and chronic central Ex-4 administration. Spectral analysis indicated that the high frequency and low frequency powers of heart rate variability were diminished by Ex-4 treatment. Finally, Ex-4 decreased both excitatory glutamatergic and inhibitory glycinergic neurotransmission to preganglionic parasympathetic cardiac vagal neurons. these data suggest that central GLP-1 receptor stimulation diminishes parasympathetic modulation of the heart thereby increasing heart rate.

  13. Heart rate turbulence as a marker of myocardial electrical instability in children with hypertrophic cardiomyopathy

    Directory of Open Access Journals (Sweden)

    V. A. Makarova

    2014-01-01

    Full Text Available Heart rate turbulence is a myocardial electrical instability marker used to stratify the risk of sudden cardiac death. Fifty children aged 7 to 17 years with hypertrophic cardiomyopathy were examined. The survey program included standard electrocardiography, Doppler echocardiography, and 24-hour Holter ECG monitoring. Heart rate turbulence parameters, such as turbulence onset and turbulence slope, were analyzed. According to turbulence onset greater than zero, heart rate turbulence impairment was identified in 5 of the 24 patients included in the survey. The abnormal turbulence slope values of less than 6 msec/RR were found in 3 patients. Both parameters were abnormal in 1 patient. Heart rate turbulence impairment was significantly more common in children with the non-obstructive form of hypertrophic cardiomyopathy than in those with its obstructive form (χ2=3,05; p=0,08. All the children with abnormal heart rhythm turbulence values had one or more major risk factors for sudden cardiac death, which significantly exceeds their rates in the normal heart rate turbulence groups (χ2=7,11; p=0,007. The patients with abnormal turbulence onset values were more often found to have syncope (χ2=3,2; p=0,02. One such patient was recorded to have unstable ventricular tachycardia (χ2=10,56; p=0,001. Our findings suggest that heart rate turbulence is an additional predictor of the unfavorable course of hypertrophic cardiomyopathy in children. 

  14. Heart rate modulation in stable coronary artery disease without clinical heart failure: What we have already learned from SIGNIFY?

    Directory of Open Access Journals (Sweden)

    Gian Piero Perna

    2016-12-01

    In conclusion, heart rate is a marker of risk but is not a risk factor and/or a target of therapy in patients with stable coronary artery disease and preserved ventricular systolic function. Standard doses of ivabradine are indicated for treatment of angina as an alternative or in addition to beta-blockers, but should not be administered in association with CYP3A4 inhibitors or heart rate-lowering calcium-channel blockers.

  15. High readmission rate after heart valve surgery

    DEFF Research Database (Denmark)

    Sibilitz, K L; Berg, S K; Thygesen, L C

    2015-01-01

    investigated. RESULTS: After valve surgery, the self-reported health was lower (Short Form-36 (SF-36) Physical Component Scale (PCS): 44.5 vs. 50.6 and Mental Component Scale (MCS): 51.9 vs. 55.0, pClinical signs......BACKGROUND: After heart valve surgery, knowledge on long-term self-reported health status and readmission is lacking. Thus, the optimal strategy for out-patient management after surgery remains unclear. METHODS: Using a nationwide survey with linkage to Danish registers with one year follow-up, we...... included all adults 6-12months after heart valve surgery irrespective of valve procedure, during Jan-June 2011 (n=867). Participants completed a questionnaire regarding health-status (n=742), and answers were compared with age- and sex-matched healthy controls. Readmission rates and mortality were...

  16. Simplifying cardiovascular risk estimation using resting heart rate.

    LENUS (Irish Health Repository)

    Cooney, Marie Therese

    2010-09-01

    Elevated resting heart rate (RHR) is a known, independent cardiovascular (CV) risk factor, but is not included in risk estimation systems, including Systematic COronary Risk Evaluation (SCORE). We aimed to derive risk estimation systems including RHR as an extra variable and assess the value of this addition.

  17. Smartphone-based photoplethysmographic imaging for heart rate monitoring.

    Science.gov (United States)

    Alafeef, Maha

    2017-07-01

    The purpose of this study is to make use of visible light reflected mode photoplethysmographic (PPG) imaging for heart rate (HR) monitoring via smartphones. The system uses the built-in camera feature in mobile phones to capture video from the subject's index fingertip. The video is processed, and then the PPG signal resulting from the video stream processing is used to calculate the subject's heart rate. Records from 19 subjects were used to evaluate the system's performance. The HR values obtained by the proposed method were compared with the actual HR. The obtained results show an accuracy of 99.7% and a maximum absolute error of 0.4 beats/min where most of the absolute errors lay in the range of 0.04-0.3 beats/min. Given the encouraging results, this type of HR measurement can be adopted with great benefit, especially in the conditions of personal use or home-based care. The proposed method represents an efficient portable solution for HR accurate detection and recording.

  18. SVM-Based Spectral Analysis for Heart Rate from Multi-Channel WPPG Sensor Signals.

    Science.gov (United States)

    Xiong, Jiping; Cai, Lisang; Wang, Fei; He, Xiaowei

    2017-03-03

    Although wrist-type photoplethysmographic (hereafter referred to as WPPG) sensor signals can measure heart rate quite conveniently, the subjects' hand movements can cause strong motion artifacts, and then the motion artifacts will heavily contaminate WPPG signals. Hence, it is challenging for us to accurately estimate heart rate from WPPG signals during intense physical activities. The WWPG method has attracted more attention thanks to the popularity of wrist-worn wearable devices. In this paper, a mixed approach called Mix-SVM is proposed, it can use multi-channel WPPG sensor signals and simultaneous acceleration signals to measurement heart rate. Firstly, we combine the principle component analysis and adaptive filter to remove a part of the motion artifacts. Due to the strong relativity between motion artifacts and acceleration signals, the further denoising problem is regarded as a sparse signals reconstruction problem. Then, we use a spectrum subtraction method to eliminate motion artifacts effectively. Finally, the spectral peak corresponding to heart rate is sought by an SVM-based spectral analysis method. Through the public PPG database in the 2015 IEEE Signal Processing Cup, we acquire the experimental results, i.e., the average absolute error was 1.01 beat per minute, and the Pearson correlation was 0.9972. These results also confirm that the proposed Mix-SVM approach has potential for multi-channel WPPG-based heart rate estimation in the presence of intense physical exercise.

  19. The Use of Heart Rate Monitors in Physical Education

    Science.gov (United States)

    Nichols, Randall; Davis, Kathryn L.; McCord, Tim; Schmidt, Dave; Slezak, Alex M.

    2009-01-01

    The ever-rising rate of obesity and the need for increased physical activity for young children is well documented. Data suggests that today's youth are not participating in enough quality health-enhancing physical activity either in or outside of school. Heart rate monitors have been used by adult exercisers for many years to monitor and assess…

  20. Thermal effect on heart rate and hemodynamics in vitelline arteries of stage 18 chicken embryos.

    Science.gov (United States)

    Lee, Jung Yeop; Lee, Sang Joon

    2010-12-01

    We investigated the thermal effects on heart rate, hemodynamics, and response of vitelline arteries of stage-18 chicken embryos. Heart rate was monitored by a high-speed imaging method, while hemodynamic quantities were evaluated using a particle image velocimetry (PIV) technique. Experiments were carried out at seven different temperatures (36-42 °C with 1 °C interval) after 1h of incubation to stabilize the heart rate. The heart rate increased in a linear manner (r = 0.992). Due to the increased cardiac output (or heart rate), the hemodynamic quantities such as mean velocity (U(mean)), velocity fluctuation (U(fluc)), and peak velocity (U(peak)) also increased with respect to the Womersley number (Ω) in the manner r = 0.599, 0.693, and 0.725, respectively. This indicates that the mechanical force exerting on the vessel walls increases. However, the active response (or regulation) of the vitelline arteries was not observed in this study. Copyright © 2010 Elsevier Ltd. All rights reserved.

  1. Construction of a bimolecular fluorescence complementation (BiFC ...

    African Journals Online (AJOL)

    Protein–protein interactions are essential for signal transduction in cells. Bimolecular fluorescence complementation (BiFC) is a novel technology that utilises green fluorescent proteins to visualize protein–protein interactions and subcellular protein localisation. BiFC based on pSATN vectors are a good system for ...

  2. Correlation of radiation dose and heart rate in dual-source computed tomography coronary angiography.

    Science.gov (United States)

    Laspas, Fotios; Tsantioti, Dimitra; Roussakis, Arkadios; Kritikos, Nikolaos; Efthimiadou, Roxani; Kehagias, Dimitrios; Andreou, John

    2011-04-01

    Computed tomography coronary angiography (CTCA) has been widely used since the introduction of 64-slice scanners and dual-source CT technology, but the relatively high radiation dose remains a major concern. To evaluate the relationship between radiation exposure and heart rate (HR), in dual-source CTCA. Data from 218 CTCA examinations, performed with a dual-source 64-slices scanner, were statistically evaluated. Effective radiation dose, expressed in mSv, was calculated as the product of the dose-length product (DLP) times a conversion coefficient for the chest (mSv = DLPx0.017). Heart rate range and mean heart rate, expressed in beats per minute (bpm) of each individual during CTCA, were also provided by the system. Statistical analysis of effective dose and heart rate data was performed by using Pearson correlation coefficient and two-sample t-test. Mean HR and effective dose were found to have a borderline positive relationship. Individuals with a mean HR >65 bpm observed to receive a statistically significant higher effective dose as compared to those with a mean HR ≤65 bpm. Moreover, a strong correlation between effective dose and variability of HR of more than 20 bpm was observed. Dual-source CT scanners are considered to have the capability to provide diagnostic examinations even with high HR and arrhythmias. However, it is desirable to keep the mean heart rate below 65 bpm and heart rate fluctuation less than 20 bpm in order to reduce the radiation exposure.

  3. HEART RATE VARIABILITY CLASSIFICATION USING SADE-ELM CLASSIFIER WITH BAT FEATURE SELECTION

    Directory of Open Access Journals (Sweden)

    R Kavitha

    2017-07-01

    Full Text Available The electrical activity of the human heart is measured by the vital bio medical signal called ECG. This electrocardiogram is employed as a crucial source to gather the diagnostic information of a patient’s cardiopathy. The monitoring function of cardiac disease is diagnosed by documenting and handling the electrocardiogram (ECG impulses. In the recent years many research has been done and developing an enhanced method to identify the risk in the patient’s body condition by processing and analysing the ECG signal. This analysis of the signal helps to find the cardiac abnormalities, arrhythmias, and many other heart problems. ECG signal is processed to detect the variability in heart rhythm; heart rate variability is calculated based on the time interval between heart beats. Heart Rate Variability HRV is measured by the variation in the beat to beat interval. The Heart rate Variability (HRV is an essential aspect to diagnose the properties of the heart. Recent development enhances the potential with the aid of non-linear metrics in reference point with feature selection. In this paper, the fundamental elements are taken from the ECG signal for feature selection process where Bat algorithm is employed for feature selection to predict the best feature and presented to the classifier for accurate classification. The popular machine learning algorithm ELM is taken for classification, integrated with evolutionary algorithm named Self- Adaptive Differential Evolution Extreme Learning Machine SADEELM to improve the reliability of classification. It combines Effective Fuzzy Kohonen clustering network (EFKCN to be able to increase the accuracy of the effect for HRV transmission classification. Hence, it is observed that the experiment carried out unveils that the precision is improved by the SADE-ELM method and concurrently optimizes the computation time.

  4. Dogs with macroadenomas have lower body temperature and heart rate than dogs with microadenomas.

    Science.gov (United States)

    Benchekroun, Ghita; Desquilbet, Loic; Herrtage, Michael E; Jeffery, Nick D; Rosenberg, Dan; Granger, Nicolas

    2017-09-01

    Pituitary macroadenomas compress the hypothalamus, which partly regulates heart rate and body temperature. The aim of this study was to investigate whether heart rate and/or body temperature could aid in clinically differentiating dogs with macroadenomas from dogs with microadenomas (i.e. small non-compressive pituitary mass). Two groups of dogs diagnosed with pituitary-dependent hyperadrenocorticism (i.e. Cushing's disease) were included. Heart rate and body temperature were collected on initial presentation before any procedure. Dogs with macroadenoma had a significantly lower heart rate and body temperature (Pdogs with microadenoma. We suggest that the combined cut-off values of 84 beats per minutes and 38.3°C in dogs with Cushing's disease, especially with vague neurological signs (nine of 12 dogs=75%), might help to suspect the presence of a macroadenoma. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Generation and Characterization of an IgG4 Monomeric Fc Platform.

    Directory of Open Access Journals (Sweden)

    Lu Shan

    Full Text Available The immunoglobulin Fc region is a homodimer consisted of two sets of CH2 and CH3 domains and has been exploited to generate two-arm protein fusions with high expression yields, simplified purification processes and extended serum half-life. However, attempts to generate one-arm fusion proteins with monomeric Fc, with one set of CH2 and CH3 domains, are often plagued with challenges such as weakened binding to FcRn or partial monomer formation. Here, we demonstrate the generation of a stable IgG4 Fc monomer with a unique combination of mutations at the CH3-CH3 interface using rational design combined with in vitro evolution methodologies. In addition to size-exclusion chromatography and analytical ultracentrifugation, we used multi-angle light scattering (MALS to show that the engineered Fc monomer exhibits excellent monodispersity. Furthermore, crystal structure analysis (PDB ID: 5HVW reveals monomeric properties supported by disrupted interactions at the CH3-CH3 interface. Monomeric Fc fusions with Fab or scFv achieved FcRn binding and serum half-life comparable to wildtype IgG. These results demonstrate that this monomeric IgG4 Fc is a promising therapeutic platform to extend the serum half-life of proteins in a monovalent format.

  6. Heart rate turbulence after ventricular premature beats in healthy Doberman pinschers and those with dilated cardiomyopathy.

    Science.gov (United States)

    Harris, J D; Little, C J L; Dennis, J M; Patteson, M W

    2017-10-01

    To describe the measurement of heart rate turbulence (HRT) after ventricular premature beats and compare HRT in healthy Doberman pinschers and those with dilated cardiomyopathy (DCM), with and without congestive heart failure (CHF). Sixty-five client-owned Dobermans: 20 healthy (NORMAL), 31 with preclinical DCM and 14 with DCM and CHF (DCM + CHF). A retrospective study of data retrieved from clinical records and ambulatory ECG (Holter) archives, including data collected previously for a large-scale prospective study of Dobermans with preclinical DCM. Holter data were reanalysed quantitatively, including conventional time-domain heart rate variability and the HRT parameters turbulence onset and turbulence slope. Heart rate turbulence could be measured in 58/65 dogs. Six Holter recordings had inadequate ventricular premature contractions (VPCs) and one exhibited VPCs too similar to sinus morphology. Heart rate turbulence parameter, turbulence onset, was significantly reduced in DCM dogs, whereas conventional heart rate variability measures were not. Heart rate variability and HRT markers were reduced in DCM + CHF dogs as expected. Heart rate turbulence can be measured from the majority of good quality standard canine 24-hour Holter recordings with >5 VPCs. Turbulence onset is significantly reduced in Dobermans with preclinical DCM which indicates vagal withdrawal early in the course of disease. Heart rate turbulence is a powerful prognostic indicator in human cardiac disease which can be measured from standard 24-hour ambulatory ECG (Holter) recordings using appropriate computer software. Further studies are warranted to assess whether HRT may be of prognostic value in dogs with preclinical DCM and in other canine cardiac disease. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Coordinate expression of activating Fc gamma receptors I and III and inhibiting Fc gamma receptor type II in the determination of joint inflammation and cartilage destruction during immune complex-mediated arthritis.

    NARCIS (Netherlands)

    Nabbe, K.C.A.M.; Blom, A.B.; Holthuysen, A.E.M.; Boross, P.; Roth, J.; Verbeek, S.; Lent, P.L.E.M. van; Berg, W.B. van den

    2003-01-01

    OBJECTIVE: To study the role of the activating Fc gamma receptor types I and III (Fc gamma RI and Fc gamma RIII, respectively) and the inhibiting Fc gamma receptor II (Fc gamma RII) in inflammation and in various aspects of cartilage destruction during arthritis that is solely induced by immune

  8. Identification of Fc Gamma Receptor Glycoforms That Produce Differential Binding Kinetics for Rituximab.

    Science.gov (United States)

    Hayes, Jerrard M; Frostell, Asa; Karlsson, Robert; Müller, Steffen; Martín, Silvia Míllan; Pauers, Martin; Reuss, Franziska; Cosgrave, Eoin F; Anneren, Cecilia; Davey, Gavin P; Rudd, Pauline M

    2017-10-01

    Fc gamma receptors (FcγR) bind the Fc region of antibodies and therefore play a prominent role in antibody-dependent cell-based immune responses such as ADCC, CDC and ADCP. The immune effector cell activity is directly linked to a productive molecular engagement of FcγRs where both the protein and glycan moiety of antibody and receptor can affect the interaction and in the present study we focus on the role of the FcγR glycans in this interaction. We provide a complete description of the glycan composition of Chinese hamster ovary (CHO) expressed human Fcγ receptors RI (CD64), RIIa Arg131/His131 (CD32a), RIIb (CD32b) and RIIIa Phe158/Val158 (CD16a) and analyze the role of the glycans in the binding mechanism with IgG. The interactions of the monoclonal antibody rituximab with each FcγR were characterized and we discuss the CHO-FcγRIIIa Phe158/Val158 and CHO-FcγRI interactions and compare them to the equivalent interactions with human (HEK293) and murine (NS0) produced receptors. Our results reveal clear differences in the binding profiles of rituximab, which we attribute in each case to the differences in host cell-dependent FcγR glycosylation. The glycan profiles of CHO expressed FcγRI and FcγRIIIa Phe158/Val158 were compared with the glycan profiles of the receptors expressed in NS0 and HEK293 cells and we show that the glycan type and abundance differs significantly between the receptors and that these glycan differences lead to the observed differences in the respective FcγR binding patterns with rituximab. Oligomannose structures are prevalent on FcγRI from each source and likely contribute to the high affinity rituximab interaction through a stabilization effect. On FcγRI and FcγRIIIa large and sialylated glycans have a negative impact on rituximab binding, likely through destabilization of the interaction. In conclusion, the data show that the IgG1-FcγR binding kinetics differ depending on the glycosylation of the FcγR and further support a

  9. Impact of space weather on human heart rate during the years 2011-2013

    Science.gov (United States)

    Galata, E.; Ioannidou, S.; Papailiou, M.; Mavromichalaki, H.; Paravolidakis, K.; Kouremeti, M.; Rentifis, L.; Simantirakis, E.; Trachanas, K.

    2017-08-01

    During the last years a possible link between different levels of solar and geomagnetic disturbances and human physiological parameters is suggested by several published studies. In this work the examination of the potential association between heart rate variations and specific space weather activities was performed. A total of 482 individuals treated at Hippocratio General Hospital in Athens, the Cardiology clinics of Nikaia General Hospital in Piraeus and the Heraklion University Hospital in Crete, Greece, were assessed from July 2011 to April 2013. The heart rate of the individuals was recorded by a Holter monitor on a n hourly basis, while the hourly variations of the cosmic ray intensity measured by the Neutron Monitor Station of the Athens University and of the geomagnetic index Dst provided by the Kyoto Observatory were used. The ANalysis Of VAriance (ANOVA) and the Multiple Linear Regression analysis were used for analysis of these data. A statistically significant effect of both cosmic rays and geomagnetic activity on heart rate was observed, which may indicate that changes in space weather could be linked to heart rate variations.

  10. Development of an Algorithm for Heart Rate Measurement Using a Mobile Phone Camera

    Directory of Open Access Journals (Sweden)

    D. A. Laure

    2014-01-01

    Full Text Available Nowadays there exist many different ways to measure a person’s heart rate. One of them assumes the usage of a mobile phone built-in camera. This method is easy to use and does not require any additional skills or special devices for heart rate measurement. It requires only a mobile cellphone with a built-in camera and a flash. The main idea of the method is to detect changes in finger skin color that occur due to blood pulsation. The measurement process is simple: the user covers the camera lens with a finger and the application on the mobile phone starts catching and analyzing frames from the camera. Heart rate can be calculated by analyzing average red component values of frames taken by the mobile cellphone camera that contain images of an area of the skin.In this paper the authors review the existing algorithms for heart rate measurement with the help of a mobile phone camera and propose their own algorithm which is more efficient than the reviewed algorithms.

  11. Identification of antibody glycosylation structures that predict monoclonal antibody Fc-effector function.

    Science.gov (United States)

    Chung, Amy W; Crispin, Max; Pritchard, Laura; Robinson, Hannah; Gorny, Miroslaw K; Yu, Xiaojie; Bailey-Kellogg, Chris; Ackerman, Margaret E; Scanlan, Chris; Zolla-Pazner, Susan; Alter, Galit

    2014-11-13

    To determine monoclonal antibody (mAb) features that predict fragment crystalizable (Fc)-mediated effector functions against HIV. Monoclonal antibodies, derived from Chinese hamster ovary cells or Epstein-Barr virus-immortalized mouse heteromyelomas, with specificity to key regions of the HIV envelope including gp120-V2, gp120-V3 loop, gp120-CD4(+) binding site, and gp41-specific antibodies, were functionally profiled to determine the relative contribution of the variable and constant domain features of the antibodies in driving robust Fc-effector functions. Each mAb was assayed for antibody-binding affinity to gp140(SR162), antibody-dependent cellular cytotoxicity (ADCC), antibody-dependent cellular phagocytosis (ADCP) and for the ability to bind to FcγRIIa, FcγRIIb and FcγRIIIa receptors. Antibody glycan profiles were determined by HPLC. Neither the specificity nor the affinity of the mAbs determined the potency of Fc-effector function. FcγRIIIa binding strongly predicted ADCC and decreased galactose content inversely correlated with ADCP, whereas N-glycolylneuraminic acid-containing structures exhibited enhanced ADCP. Additionally, the bi-antenary glycan arm onto which galactose was added predicted enhanced binding to FcγRIIIa and ADCC activity, independent of the specificity of the mAb. Our studies point to the specific Fc-glycan structures that can selectively promote Fc-effector functions independently of the antibody specificity. Furthermore, we demonstrated antibody glycan structures associated with enhanced ADCP activity, an emerging Fc-effector function that may aid in the control and clearance of HIV infection.

  12. Heart rate, heart rate variability, and arrhythmias in dogs with myxomatous mitral valve disease

    DEFF Research Database (Denmark)

    Rasmussen, Caroline Elisabeth; Falk, Bo Torkel; Zois, Nora Elisabeth

    2012-01-01

    Autonomic modulation of heart rhythm is thought to influence the pathophysiology of myxomatous mitral valve disease (MMVD).......Autonomic modulation of heart rhythm is thought to influence the pathophysiology of myxomatous mitral valve disease (MMVD)....

  13. Neonatal heart rate prediction.

    Science.gov (United States)

    Abdel-Rahman, Yumna; Jeremic, Aleksander; Tan, Kenneth

    2009-01-01

    Technological advances have caused a decrease in the number of infant deaths. Pre-term infants now have a substantially increased chance of survival. One of the mechanisms that is vital to saving the lives of these infants is continuous monitoring and early diagnosis. With continuous monitoring huge amounts of data are collected with so much information embedded in them. By using statistical analysis this information can be extracted and used to aid diagnosis and to understand development. In this study we have a large dataset containing over 180 pre-term infants whose heart rates were recorded over the length of their stay in the Neonatal Intensive Care Unit (NICU). We test two types of models, empirical bayesian and autoregressive moving average. We then attempt to predict future values. The autoregressive moving average model showed better results but required more computation.

  14. Production and characterization of soluble human TNFRI-Fc and human HO-1(HMOX1) transgenic pigs by using the F2A peptide.

    Science.gov (United States)

    Park, Sol Ji; Cho, Bumrae; Koo, Ok Jae; Kim, Hwajung; Kang, Jung Taek; Hurh, Sunghoon; Kim, Su Jin; Yeom, Hye Jung; Moon, Joonho; Lee, Eun Mi; Choi, Ji Yei; Hong, Ju Ho; Jang, Goo; Hwang, Joing-Ik; Yang, Jaeseok; Lee, Byeong Chun; Ahn, Curie

    2014-06-01

    Generation of transgenic pigs for xenotransplantation is one of the most promising technologies for resolving organ shortages. Human heme oxygenase-1 (hHO-1/HMOX1) can protect transplanted organs by its strong anti-oxidative, anti-apoptotic, and anti-inflammatory effects. Soluble human TNFRI-Fc (shTNFRI-Fc) can inhibit the binding of human TNF-α (hTNF-α) to TNF receptors on porcine cells, and thereby, prevent hTNF-α-mediated inflammation and apoptosis. Herein, we successfully generated shTNFRI-Fc-F2A-HA-hHO-1 transgenic (TG) pigs expressing both shTNFRI-Fc and hemagglutinin-tagged-human heme oxygenase-1 (HA-hHO-1) by using an F2A self-cleaving peptide. shTNFRI-Fc and HA-hHO-1 transgenes containing the F2A peptide were constructed under the control of the CAG promoter. Transgene insertion and copy number in the genome of transgenic pigs was confirmed by polymerase chain reaction (PCR) and Southern blot analysis. Expressions of shTNFRI-Fc and HA-hHO-1 in TG pigs were confirmed using PCR, RT-PCR, western blot, ELISA, and immunohistochemistry. shTNFRI-Fc and HA-hHO-1 were expressed in various organs, including the heart, lung, and spleen. ELISA assays detected shTNFRI-Fc in the sera of TG pigs. For functional analysis, fibroblasts isolated from a shTNFRI-Fc-F2A-HA-hHO-1 TG pig (i.e., #14; 1 × 10(5) cells) were cultured with hTNF-α (20 ng/mL) and cycloheximide (10 μg/mL). The viability of shTNFRI-Fc-F2A-HA-hHO-1 TG pig fibroblasts was significantly higher than that of the wild type (wild type vs. shTNFRI-Fc-F2A-HA-hHO-1 TG at 24 h, 31.6 ± 3.2 vs. 60.4 ± 8.3 %, respectively; p hHO-1 TG pig fibroblasts was lower than that of the wild type pig fibroblasts (wild type vs. shTNFRI-Fc-F2A-HA-hHO-1 TG at 12 h, 812,452 ± 113,078 RLU vs. 88,240 ± 10,438 RLU, respectively; p hHO-1 TG pigs generated by the F2A self-cleaving peptide express both shTNFRI-Fc and HA-hHO-1 molecules, which provides protection against oxidative and inflammatory injury

  15. Making the Most of the "Daphnia" Heart Rate Lab: Optimizing the Use of Ethanol, Nicotine & Caffeine

    Science.gov (United States)

    Corotto, Frank; Ceballos, Darrel; Lee, Adam; Vinson, Lindsey

    2010-01-01

    Students commonly test the effects of chemical agents on the heart rate of the crustacean "Daphnia" magna, but the procedure has never been optimized. We determined the effects of three concentrations of ethanol, nicotine, and caffeine and of a control solution on heart rate in "Daphnia." Ethanol at 5% and 10% (v/v) reduced mean heart rate to…

  16. Heart Rate, Stress, and Occupational Noise Exposure among Electronic Waste Recycling Workers.

    Science.gov (United States)

    Burns, Katrina N; Sun, Kan; Fobil, Julius N; Neitzel, Richard L

    2016-01-19

    Electronic waste (e-waste) is a growing occupational and environmental health issue around the globe. E-waste recycling is a green industry of emerging importance, especially in low-and middle-income countries where much of this recycling work is performed, and where many people's livelihoods depend on this work. The occupational health hazards of e-waste recycling have not been adequately explored. We performed a cross-sectional study of noise exposures, heart rate, and perceived stress among e-waste recycling workers at a large e-waste site in Accra, Ghana. We interviewed 57 workers and continuously monitored their individual noise exposures and heart rates for up to 24 h. More than 40% of workers had noise exposures that exceeded recommended occupational (85 dBA) and community (70 dBA) noise exposure limits, and self-reported hearing difficulties were common. Workers also had moderate to high levels of perceived stress as measured via Cohen's Perceived Stress Scale, and reported a variety of symptoms that could indicate cardiovascular disease. Noise exposures were moderately and significantly correlated with heart rate (Spearman's ρ 0.46, p stress, and unfavorable physical working conditions. These findings suggest that occupational and non-occupational noise exposure is associated with elevations in average heart rate, which may in turn predict potential cardiovascular damage.

  17. Heart rate response to a climber’s fall in sport climbing

    OpenAIRE

    Chaloupsky, David

    2015-01-01

    The research deals with response of heart rate to a climber’s simulated fall in a leading position when indoor climbing. Heart rate of climbers was recorded during ascents of an overhanging route in the leading position, to the given point high above the ground, followed by falling into the last protection. The length of the free fall was defined by the place of the last belay anchor, which was at the height of climber’s ankles. The length of the fall was about two meters of free fall plus th...

  18. Attenuated heart rate response in REM sleep behavior disorder and Parkinson's disease

    DEFF Research Database (Denmark)

    Sorensen, Gertrud Laura; Kempfner, Jacob; Zoetmulder, Marielle

    2012-01-01

    The objective of this study was to determine whether patients with Parkinson's disease with and without rapid‐eye‐movement sleep behavior disorder and patients with idiopathic rapid‐eye‐movement sleep behavior disorder have an attenuated heart rate response to arousals or to leg movements during...... sleep compared with healthy controls. Fourteen and 16 Parkinson's patients with and without rapid‐eye‐movement sleep behavior disorder, respectively, 11 idiopathic rapid‐eye‐movement sleep behavior disorder patients, and 17 control subjects underwent 1 night of polysomnography. The heart rate response...... associated with arousal or leg movement from all sleep stages was analyzed from 10 heartbeats before the onset of the sleep event to 15 heartbeats following onset of the sleep event. The heart rate reponse to arousals was significantly lower in both parkinsonian groups compared with the control group...

  19. Heart-Rate Variability—More than Heart Beats?

    Directory of Open Access Journals (Sweden)

    Gernot Ernst

    2017-09-01

    Full Text Available Heart-rate variability (HRV is frequently introduced as mirroring imbalances within the autonomous nerve system. Many investigations are based on the paradigm that increased sympathetic tone is associated with decreased parasympathetic tone and vice versa. But HRV is probably more than an indicator for probable disturbances in the autonomous system. Some perturbations trigger not reciprocal, but parallel changes of vagal and sympathetic nerve activity. HRV has also been considered as a surrogate parameter of the complex interaction between brain and cardiovascular system. Systems biology is an inter-disciplinary field of study focusing on complex interactions within biological systems like the cardiovascular system, with the help of computational models and time series analysis, beyond others. Time series are considered surrogates of the particular system, reflecting robustness or fragility. Increased variability is usually seen as associated with a good health condition, whereas lowered variability might signify pathological changes. This might explain why lower HRV parameters were related to decreased life expectancy in several studies. Newer integrating theories have been proposed. According to them, HRV reflects as much the state of the heart as the state of the brain. The polyvagal theory suggests that the physiological state dictates the range of behavior and psychological experience. Stressful events perpetuate the rhythms of autonomic states, and subsequently, behaviors. Reduced variability will according to this theory not only be a surrogate but represent a fundamental homeostasis mechanism in a pathological state. The neurovisceral integration model proposes that cardiac vagal tone, described in HRV beyond others as HF-index, can mirror the functional balance of the neural networks implicated in emotion–cognition interactions. Both recent models represent a more holistic approach to understanding the significance of HRV.

  20. Heart-Rate Variability-More than Heart Beats?

    Science.gov (United States)

    Ernst, Gernot

    2017-01-01

    Heart-rate variability (HRV) is frequently introduced as mirroring imbalances within the autonomous nerve system. Many investigations are based on the paradigm that increased sympathetic tone is associated with decreased parasympathetic tone and vice versa . But HRV is probably more than an indicator for probable disturbances in the autonomous system. Some perturbations trigger not reciprocal, but parallel changes of vagal and sympathetic nerve activity. HRV has also been considered as a surrogate parameter of the complex interaction between brain and cardiovascular system. Systems biology is an inter-disciplinary field of study focusing on complex interactions within biological systems like the cardiovascular system, with the help of computational models and time series analysis, beyond others. Time series are considered surrogates of the particular system, reflecting robustness or fragility. Increased variability is usually seen as associated with a good health condition, whereas lowered variability might signify pathological changes. This might explain why lower HRV parameters were related to decreased life expectancy in several studies. Newer integrating theories have been proposed. According to them, HRV reflects as much the state of the heart as the state of the brain. The polyvagal theory suggests that the physiological state dictates the range of behavior and psychological experience. Stressful events perpetuate the rhythms of autonomic states, and subsequently, behaviors. Reduced variability will according to this theory not only be a surrogate but represent a fundamental homeostasis mechanism in a pathological state. The neurovisceral integration model proposes that cardiac vagal tone, described in HRV beyond others as HF-index, can mirror the functional balance of the neural networks implicated in emotion-cognition interactions. Both recent models represent a more holistic approach to understanding the significance of HRV.

  1. Effects of slow breathing rate on heart rate variability and arterial baroreflex sensitivity in essential hypertension.

    Science.gov (United States)

    Li, Changjun; Chang, Qinghua; Zhang, Jia; Chai, Wenshu

    2018-05-01

    This study is to investigate the effects of slow breathing on heart rate variability (HRV) and arterial baroreflex sensitivity in essential hypertension.We studied 60 patients with essential hypertension and 60 healthy controls. All subjects underwent controlled breathing at 8 and 16 breaths per minute. Electrocardiogram, respiratory, and blood pressure signals were recorded simultaneously. We studied effects of slow breathing on heart rate, blood pressure and respiratory peak, high-frequency (HF) power, low-frequency (LF) power, and LF/HF ratio of HRV with traditional and corrected spectral analysis. Besides, we tested whether slow breathing was capable of modifying baroreflex sensitivity in hypertensive subjects.Slow breathing, compared with 16 breaths per minute, decreased the heart rate and blood pressure (all P hypertensive subjects. Slow breathing increased baroreflex sensitivity in hypertensive subjects (from 59.48 ± 6.39 to 78.93 ± 5.04 ms/mm Hg, P hypertension. Besides, slow breathing increased baroreflex sensitivity in hypertensive subjects. These demonstrate slow breathing is indeed capable of shifting sympatho-vagal balance toward vagal activities and increasing baroreflex sensitivity, suggesting a safe, therapeutic approach for essential hypertension.

  2. Study of foetal heart rate patterns in pregnancy with intra-uterine growth restriction during antepartum period

    International Nuclear Information System (INIS)

    Fardiazar, Z.; Abassalizade, F.

    2013-01-01

    Objectives: To evaluate foetal heart rate pattern during antepartum period in pregnancies suffering from intra-uterine growth restriction. Methods: The case control study was conducted at the Alzahra Hospital, Tabriz, Iran from April 2008 to April 2011. It comprised 100 pregnancies with intra-uterine growth restriction and 92 normal pregnancies. The foetal heart rate pattern including basal heart rate, beat-to-beat variation, non-stress test (NST) result and acceleration and deceleration patterns of the heart rate were determined in both groups during the antepartum period. Findings were compared between the two groups and their relation with pregnancy-foetal outcomes was specified in the case group. SPSS 15 was used for statistical analysis. Results: There was no statistically significant difference between the foetus mean basal heart rate in the two groups (p <0.960). Frequency of cases with non-reactive non-stress test in the Cases was significantly higher than Controls (p <0.005). The difference in heart rate acceleration was also not statistically significant (p <0.618). Frequency of cases with low birth weight and caesarian was non-significantly but borderline higher among the Cases (p <0.081 and 0.060, respectively). Conclusion: Abnormal foetal heart rate pattern is more common in pregnancies marked by intra-uterine growth restriction and is directly associated with worse pregnancy/foetal outcomes. (author)

  3. Heart Rate Variability Is Associated with Exercise Capacity in Patients with Cardiac Syndrome X.

    Directory of Open Access Journals (Sweden)

    Dai-Yin Lu

    Full Text Available Heart rate variability (HRV reflects the healthiness of autonomic nervous system, which is associated with exercise capacity. We therefore investigated whether HRV could predict the exercise capacity in the adults with cardiac syndrome X (CSX. A total of 238 subjects (57±12 years, 67.8% men, who were diagnosed as CSX by the positive exercise stress test and nearly normal coronary angiogram were enrolled. Power spectrum from the 24-hour recording of heart rate was analyzed in frequency domain using total power (TP and spectral components of the very low frequency (VLF, low frequency (LF and high frequency (HF ranges. Among the study population, 129 subjects with impaired exercise capacity during the treadmill test had significantly lower HRV indices than those with preserved exercise capacity (≥90% of the age predicted maximal heart rate. After accounting for age, sex, and baseline SBP and heart rate, VLF (odds ratio per 1SD and 95% CI: 2.02, 1.19-3.42, LF (1.67, 1.10-2.55, and TP (1.82, 1.17-2.83 remained significantly associated with preserved exercise capacity. In addition, increased HRV indices were also associated with increased exercise duration, rate-pressure product, and heart rate recovery, independent of age, body mass index, and baseline SBP and heart rate. In subgroup analysis, HRV indices demonstrated similar predictive values related to exercise capacity across various subpopulations, especially in the young. In patients with CSX, HRV was independently associated with exercise capacity, especially in young subjects. The healthiness of autonomic nervous system may have a role in modulating the exercise capacity in patients with CSX.

  4. Correlation of radiation dose and heart rate in dual-source computed tomography coronary angiography

    International Nuclear Information System (INIS)

    Laspas, Fotios; Roussakis, Arkadios; Kritikos, Nikolaos; Efthimiadou, Roxani; Kehagias, Dimitrios; Andreou, John; Tsantioti, Dimitra

    2011-01-01

    Background: Computed tomography coronary angiography (CTCA) has been widely used since the introduction of 64-slice scanners and dual-source CT technology, but the relatively high radiation dose remains a major concern. Purpose: To evaluate the relationship between radiation exposure and heart rate (HR), in dual-source CTCA. Material and Methods: Data from 218 CTCA examinations, performed with a dual-source 64-slices scanner, were statistically evaluated. Effective radiation dose, expressed in mSv, was calculated as the product of the dose-length product (DLP) times a conversion coefficient for the chest (mSv = DLPx0.017). Heart rate range and mean heart rate, expressed in beats per minute (bpm) of each individual during CTCA, were also provided by the system. Statistical analysis of effective dose and heart rate data was performed by using Pearson correlation coefficient and two-sample t-test. Results: Mean HR and effective dose were found to have a borderline positive relationship. Individuals with a mean HR >65 bpm observed to receive a statistically significant higher effective dose as compared to those with a mean HR =65 bpm. Moreover, a strong correlation between effective dose and variability of HR of more than 20 bpm was observed. Conclusion: Dual-source CT scanners are considered to have the capability to provide diagnostic examinations even with high HR and arrhythmias. However, it is desirable to keep the mean heart rate below 65 bpm and heart rate fluctuation less than 20 bpm in order to reduce the radiation exposure

  5. [Design of Oxygen Saturation, Heart Rate, Respiration Rate Detection System Based on Smartphone of Android Operating System].

    Science.gov (United States)

    Zhu, Mingshan; Zeng, Bixin

    2015-03-01

    In this paper, we designed an oxygen saturation, heart rate, respiration rate monitoring system based on smartphone of android operating system, physiological signal acquired by MSP430 microcontroller and transmitted by Bluetooth module.

  6. SVM-Based Spectral Analysis for Heart Rate from Multi-Channel WPPG Sensor Signals

    Directory of Open Access Journals (Sweden)

    Jiping Xiong

    2017-03-01

    Full Text Available Although wrist-type photoplethysmographic (hereafter referred to as WPPG sensor signals can measure heart rate quite conveniently, the subjects’ hand movements can cause strong motion artifacts, and then the motion artifacts will heavily contaminate WPPG signals. Hence, it is challenging for us to accurately estimate heart rate from WPPG signals during intense physical activities. The WWPG method has attracted more attention thanks to the popularity of wrist-worn wearable devices. In this paper, a mixed approach called Mix-SVM is proposed, it can use multi-channel WPPG sensor signals and simultaneous acceleration signals to measurement heart rate. Firstly, we combine the principle component analysis and adaptive filter to remove a part of the motion artifacts. Due to the strong relativity between motion artifacts and acceleration signals, the further denoising problem is regarded as a sparse signals reconstruction problem. Then, we use a spectrum subtraction method to eliminate motion artifacts effectively. Finally, the spectral peak corresponding to heart rate is sought by an SVM-based spectral analysis method. Through the public PPG database in the 2015 IEEE Signal Processing Cup, we acquire the experimental results, i.e., the average absolute error was 1.01 beat per minute, and the Pearson correlation was 0.9972. These results also confirm that the proposed Mix-SVM approach has potential for multi-channel WPPG-based heart rate estimation in the presence of intense physical exercise.

  7. Real-time Continuous Assessment Method for Mental and Physiological Condition using Heart Rate Variability

    Science.gov (United States)

    Yoshida, Yutaka; Yokoyama, Kiyoko; Ishii, Naohiro

    It is necessary to monitor the daily health condition for preventing stress syndrome. In this study, it was proposed the method assessing the mental and physiological condition, such as the work stress or the relaxation, using heart rate variability at real time and continuously. The instantanuous heart rate (HR), and the ratio of the number of extreme points (NEP) and the number of heart beats were calculated for assessing mental and physiological condition. In this method, 20 beats heart rate were used to calculate these indexes. These were calculated in one beat interval. Three conditions, which are sitting rest, performing mental arithmetic and watching relaxation movie, were assessed using our proposed algorithm. The assessment accuracies were 71.9% and 55.8%, when performing mental arithmetic and watching relaxation movie respectively. In this method, the mental and physiological condition was assessed using only 20 regressive heart beats, so this method is considered as the real time assessment method.

  8. ARTiiFACT: a tool for heart rate artifact processing and heart rate variability analysis.

    Science.gov (United States)

    Kaufmann, Tobias; Sütterlin, Stefan; Schulz, Stefan M; Vögele, Claus

    2011-12-01

    The importance of appropriate handling of artifacts in interbeat interval (IBI) data must not be underestimated. Even a single artifact may cause unreliable heart rate variability (HRV) results. Thus, a robust artifact detection algorithm and the option for manual intervention by the researcher form key components for confident HRV analysis. Here, we present ARTiiFACT, a software tool for processing electrocardiogram and IBI data. Both automated and manual artifact detection and correction are available in a graphical user interface. In addition, ARTiiFACT includes time- and frequency-based HRV analyses and descriptive statistics, thus offering the basic tools for HRV analysis. Notably, all program steps can be executed separately and allow for data export, thus offering high flexibility and interoperability with a whole range of applications.

  9. Heart rate responses induced by acoustic tempo and its interaction with basal heart rate.

    Science.gov (United States)

    Watanabe, Ken; Ooishi, Yuuki; Kashino, Makio

    2017-03-07

    Many studies have revealed the influences of music on the autonomic nervous system (ANS). Since previous studies focused on the effects of acoustic tempo on the ANS, and humans have their own physiological oscillations such as the heart rate (HR), the effects of acoustic tempo might depend on the HR. Here we show the relationship between HR elevation induced by acoustic tempo and individual basal HR. Since high tempo-induced HR elevation requires fast respiration, which is based on sympatho-respiratory coupling, we controlled the participants' respiration at a faster rate (20 CPM) than usual (15 CPM). We found that sound stimuli with a faster tempo than the individual basal HR increased the HR. However, the HR increased following a gradual increase in the acoustic tempo only when the extent of the gradual increase in tempo was within a specific range (around + 2%/min). The HR did not follow the increase in acoustic tempo when the rate of the increase in the acoustic tempo exceeded 3% per minute. These results suggest that the effect of the sympatho-respiratory coupling underlying the HR elevation caused by a high acoustic tempo depends on the basal HR, and the strength and the temporal dynamics of the tempo.

  10. Dynamic neural networking as a basis for plasticity in the control of heart rate.

    Science.gov (United States)

    Kember, G; Armour, J A; Zamir, M

    2013-01-21

    A model is proposed in which the relationship between individual neurons within a neural network is dynamically changing to the effect of providing a measure of "plasticity" in the control of heart rate. The neural network on which the model is based consists of three populations of neurons residing in the central nervous system, the intrathoracic extracardiac nervous system, and the intrinsic cardiac nervous system. This hierarchy of neural centers is used to challenge the classical view that the control of heart rate, a key clinical index, resides entirely in central neuronal command (spinal cord, medulla oblongata, and higher centers). Our results indicate that dynamic networking allows for the possibility of an interplay among the three populations of neurons to the effect of altering the order of control of heart rate among them. This interplay among the three levels of control allows for different neural pathways for the control of heart rate to emerge under different blood flow demands or disease conditions and, as such, it has significant clinical implications because current understanding and treatment of heart rate anomalies are based largely on a single level of control and on neurons acting in unison as a single entity rather than individually within a (plastically) interconnected network. Copyright © 2012 Elsevier Ltd. All rights reserved.

  11. Heart Rate Monitors Promote Physical Education for Children

    Science.gov (United States)

    Tipton, Jan; Sander, Allan N.

    2004-01-01

    National health and fitness data suggests that a significant percentage of children are not on a pathway to leading healthy, physically active lifestyles. Many children are leading sedentary lifestyles due to a lack of opportunity, success, or self-motivation in physical activity. Programs that highlight the use of heart rate monitors offer a…

  12. Influence of Prolonged Spaceflight on Heart Rate and Oxygen Uptake Kinetics

    Science.gov (United States)

    Hoffmann, U.; Moore, A.; Drescher, U.

    2013-02-01

    During prolonged spaceflight, physical training is used to minimize cardiovascular deconditioning. Measurement of the kinetics of cardiorespiratory parameters, in particular the kinetic analysis of heart rate, respiratory and muscular oxygen uptake, provides useful information with regard to the efficiency and regulation of the cardiorespiratory system. Practically, oxygen uptake kinetics can only be measured at the lung site (V’O2 resp). The dynamics of V’O2 resp, however, is not identical with the dynamics at the site of interest: skeletal muscle. Eight Astronauts were tested pre- and post-flight using pseudo random binary workload changes between 30 and 80 W. Their kinetic responses of heart rate, respiratory as well as muscular V’O2 kinetics were estimated by using time-series analysis. Statistical analysis revealed that the kinetic responses of respiratory as well as muscular V’O2 kinetics are slowed post-flight than pre-flight. Heart rate seems not to be influenced following flight. The influence of other factors (e. g. astronauts’ exercise training) may impact these parameters and is an area for future studies.

  13. Estimation of physical work load by statistical analysis of the heart rate in a conveyor-belt worker.

    Science.gov (United States)

    Kontosic, I; Vukelić, M; Pancić, M; Kunisek, J

    1994-12-01

    Physical work load was estimated in a female conveyor-belt worker in a bottling plant. Estimation was based on continuous measurement and on calculation of average heart rate values in three-minute and one-hour periods and during the total measuring period. The thermal component of the heart rate was calculated by means of the corrected effective temperature, for the one-hour periods. The average heart rate at rest was also determined. The work component of the heart rate was calculated by subtraction of the resting heart rate and the heart rate measured at 50 W, using a regression equation. The average estimated gross energy expenditure during the work was 9.6 +/- 1.3 kJ/min corresponding to the category of light industrial work. The average estimated oxygen uptake was 0.42 +/- 0.06 L/min. The average performed mechanical work was 12.2 +/- 4.2 W, i.e. the energy expenditure was 8.3 +/- 1.5%.

  14. Label-free Fab and Fc affinity/avidity profiling of the antibody complex half-life for polyclonal and monoclonal efficacy screening.

    Science.gov (United States)

    Read, Thomas; Olkhov, Rouslan V; Williamson, E Diane; Shaw, Andrew M

    2015-09-01

    A unified approach to affinity screening for Fab and Fc interactions of an antibody for its antigen and FcγR receptor has been developed. An antigen array is used for the Fab affinity and cross-reactivity screening and protein A/G proxy is the FcγR receptor. The affinities are derived using a simple 1:1 binding model with a consistent error analysis. The association and dissociation kinetics are measured over optimised times for accurate determination. The Fab/Fc affinities are derived for ten antibodies: mAb-actin (mouse), pAb-BSA (sheep), pAb-collagen V (rabbit), pAb-CRP (goat), mAb-F1 (mouse), mAbs (mouse) 7.3, 12.3, 29.3, 36.3 and 46.3 raised against LcrV in Yersinia pestis. The rate of the dissociation of antigen-antibody complexes relates directly to their immunological function as does the Fc-FcγR complex and a new half-life plot has been defined with a Fab/Fc half-life range of 17-470 min. The upper half-life value points to surface avidity. Two antibodies that are protective as an immunotherapy define a Fab half-life >250 min and an Fc half-life >50 min as characteristics of ideal interactions which can form the basis of an antibody screen for immunotherapy.

  15. [Evaluation of heart impact in the 100 m extreme intensity sport using near-infrared non-invasive muscle oxygen detecting device and sports heart rate detection technology].

    Science.gov (United States)

    Wang, Pei-Yong; Long, Fei-Xiao; Fu, Lan-Ying; Li, Yue; Ding, Hai-Shu; Qu, An-Lian; Zhou, Xiao-Ping

    2010-02-01

    Using continuous two wavelength near-infrared technology to detect the variation in the consistency of oxygen hemoglobin in the muscle and the sports heart rate wireless real time collection technology, we devised the real time muscle tissue oxygenation and instantaneous heart rate experiment scheme and implemented it for the process of the 100 m run with two parameters given simultaneously. The experiment shows that the concentration of the oxygen hemoglobin in the muscle tissue continues decreasing after the end of the 100 m run, and the time interval between the moment when the concentration of the oxygen hemoglobin attains the minimum value and the moment when the athletes finish the 100 m run is (6.65 +/- 1.10) sec; while the heart rate continues increasing after the end of the 100 m run, and the time interval between the moment when the heart rate attains the maximum value and the moment when the athletes finish the 100 m run is (8.00 +/- 1.57) sec. The results show that the two wavelength near-infrared tissue oxygenation detection technology and the sports heart rate real time collection equipment can accurately measure the sports tissue oxygenation and the heart rate in the extreme intensity sport, and reveal the process of muscle oxygen transportation and consumption and its dynamic character with the heart rate in the extreme intensity sport.

  16. The modulatory effects of noradrenaline on vagal control of heart rate in the dogfish, Squalus acanthias.

    Science.gov (United States)

    Agnisola, Claudio; Randall, David J; Taylor, Edwin W

    2003-01-01

    The possible interactions between inhibitory vagal control of the heart and circulating levels of catecholamines in dogfish (Squalus acanthias) were studied using an in situ preparation of the heart, which retained intact its innervation from centrally cut vagus nerves. The response to peripheral vagal stimulation typically consisted of an initial cardiac arrest, followed by an escape beat, leading to renewed beating at a mean heart rate lower than the prestimulation rate (partial recovery). Cessation of vagal stimulation led to a transient increase in heart rate, above the prestimulation rate. This whole response was completely abolished by 10(-4) M atropine (a muscarinic cholinergic antagonist). The degree of vagal inhibition was evaluated in terms of both the initial, maximal cardiac interval and the mean heart rate during partial recovery, both expressed as a percentage of the prestimulation heart rate. The mean prestimulation heart rate of this preparation (36+/-4 beats min(-1)) was not affected by noradrenaline but was significantly reduced by 10(-4) M nadolol (a beta-adrenergic receptor antagonist), suggesting the existence of a resting adrenergic tone arising from endogenous catecholamines. The degree of vagal inhibition of heart rate varied with the rate of stimulation and was increased by the presence of 10(-8) M noradrenaline (the normal in vivo level in routinely active fish), while 10(-7) M noradrenaline (the in vivo level measured in disturbed or deeply hypoxic fish) reduced the cardiac response to vagal stimulation. In the presence of 10(-7) M noradrenaline, 10(-4) M nadolol further reduced the vagal response, while 10(-4) M nadolol + 10(-4) M phentolamine had no effect, indicating a complex interaction between adrenoreceptors, possibly involving presynaptic modulation of vagal inhibition.

  17. Heart Disease Death Rates Among Blacks and Whites Aged ≥35 Years — United States, 1968–2015

    Science.gov (United States)

    Van Dyke, Miriam; Greer, Sophia; Odom, Erika; Schieb, Linda; Vaughan, Adam; Kramer, Michael; Casper, Michele

    2018-01-01

    Problem/Condition Heart disease is the leading cause of death in the United States. In 2015, heart disease accounted for approximately 630,000 deaths, representing one in four deaths in the United States. Although heart disease death rates decreased 68% for the total population from 1968 to 2015, marked disparities in decreases exist by race and state. Period Covered 1968–2015. Description of System The National Vital Statistics System (NVSS) data on deaths in the United States were abstracted for heart disease using diagnosis codes from the eighth, ninth, and tenth revisions of the International Classification of Diseases (ICD-8, ICD-9, and ICD-10) for 1968–2015. Population estimates were obtained from NVSS files. National and state-specific heart disease death rates for the total population and by race for adults aged ≥35 years were calculated for 1968–2015. National and state-specific black-white heart disease mortality ratios also were calculated. Death rates were age standardized to the 2000 U.S. standard population. Joinpoint regression was used to perform time trend analyses. Results From 1968 to 2015, heart disease death rates decreased for the total U.S. population among adults aged ≥35 years, from 1,034.5 to 327.2 per 100,000 population, respectively, with variations in the magnitude of decreases by race and state. Rates decreased for the total population an average of 2.4% per year, with greater average decreases among whites (2.4% per year) than blacks (2.2% per year). At the national level, heart disease death rates for blacks and whites were similar at the start of the study period (1968) but began to diverge in the late 1970s, when rates for blacks plateaued while rates for whites continued to decrease. Heart disease death rates among blacks remained higher than among whites for the remainder of the study period. Nationwide, the black-white ratio of heart disease death rates increased from 1.04 in 1968 to 1.21 in 2015, with large increases

  18. Prophylactic anti-D preparations display variable decreases in Fc-fucosylation of anti-D.

    Science.gov (United States)

    Kapur, Rick; Della Valle, Luciana; Verhagen, Onno J H M; Hipgrave Ederveen, Agnes; Ligthart, Peter; de Haas, Masja; Kumpel, Belinda; Wuhrer, Manfred; van der Schoot, C Ellen; Vidarsson, Gestur

    2015-03-01

    RhIG is obtained from hyperimmunized healthy anti-D donors (HIDs) boosted with D+ red blood cells (RBCs). One hypothesis for its mechanism of action is fast clearance of opsonized D+ RBCs through Fcγ receptor (FcγR)III. Levels of immunoglobulin (Ig)G Fc-fucosylation influence interactions with FcγRIII, with less Fc-fucosylation strengthening the interaction. Anti-D IgG1 Fc-glycosylation patterns in 93 plasma samples from 28 male and 28 female Dutch HIDs and RhIG were analyzed with mass spectrometry. The Fc-glycosylation profiles of HIDs were evaluated with regard to their immunization history. HID sera demonstrated clearly lowered anti-D Fc-fucosylation compared to normal IgG fucosylation (93%); this was more pronounced for female than for male HIDs (47% vs. 65%, p = 0.001). RhIG preparations from seven manufacturers varied greatly in the level of Fc-fucosylation (56%-91%). The level of fucosylation slightly increased upon repeated immunization, although it remained fairly constant over time. The RhIG from the different manufacturers all demonstrated increased Fc-galactosylation (64%-82%) compared to total IgG (38%-51%). RhIG preparations vary in Fc-fucosylation and all demonstrate increased galactosylation. Despite not knowing the exact working mechanism, immunoprophylaxis could perhaps be optimized by selection of donors whose anti-D have low amounts of Fc-fucose, to increase the clearance activity of anti-D preparations, as well as high amounts of galactosylation, for anti-inflammatory effects. Implementing a biologic assay in the standardization of RhIG preparations might be considered. © 2014 AABB.

  19. Electrodes as social glue: measuring heart rate promotes giving in the trust game.

    Science.gov (United States)

    Van Lange, Paul A M; Finkenauer, Catrin; Popma, Arne; van Vugt, Mark

    2011-06-01

    While physiological measures are increasingly used to help us understand the workings of interpersonal trust (and related behaviors), we know very little about the effects of such measures on trust. We examined the effects of a classic measure, the measurement of heart rate using a standard protocol, on behavioral trust in dyads of women who did not know each other. Behavioral trust was assessed in the trust game, in which the trustor decides how much money from their subject payment to give to a trustee, while knowing that the experimenter triples that amount before giving it to the trustee, after which the trustee decides how much money to return to the trustor. As predicted, we found greater levels of behavioral trust in the trust game, as well as greater returns by the trustees (which were accounted for by trustor's giving), in the heart rate (HR) than in no heart rate (NHR) measurement condition. Parallel findings were observed for self-reported trust. Findings are discussed in terms of the idea that the elusive effects of a protocol for measuring heart rate can cause pronounced effects on subsequent social interactions via enhanced interpersonal trust. 2011 Elsevier B.V. All rights reserved.

  20. Heart rate responses to autonomic challenges in obstructive sleep apnea.

    Directory of Open Access Journals (Sweden)

    Paul M Macey

    Full Text Available Obstructive sleep apnea (OSA is accompanied by structural alterations and dysfunction in central autonomic regulatory regions, which may impair dynamic and static cardiovascular regulation, and contribute to other syndrome pathologies. Characterizing cardiovascular responses to autonomic challenges may provide insights into central nervous system impairments, including contributions by sex, since structural alterations are enhanced in OSA females over males. The objective was to assess heart rate responses in OSA versus healthy control subjects to autonomic challenges, and, separately, characterize female and male patterns. We studied 94 subjects, including 37 newly-diagnosed, untreated OSA patients (6 female, age mean ± std: 52.1 ± 8.1 years; 31 male aged 54.3 ± 8.4 years, and 57 healthy control subjects (20 female, 50.5 ± 8.1 years; 37 male, 45.6 ± 9.2 years. We measured instantaneous heart rate with pulse oximetry during cold pressor, hand grip, and Valsalva maneuver challenges. All challenges elicited significant heart rate differences between OSA and control groups during and after challenges (repeated measures ANOVA, p<0.05. In post-hoc analyses, OSA females showed greater impairments than OSA males, which included: for cold pressor, lower initial increase (OSA vs. control: 9.5 vs. 7.3 bpm in females, 7.6 vs. 3.7 bpm in males, OSA delay to initial peak (2.5 s females/0.9 s males, slower mid-challenge rate-of-increase (OSA vs. control: -0.11 vs. 0.09 bpm/s in females, 0.03 vs. 0.06 bpm/s in males; for hand grip, lower initial peak (OSA vs. control: 2.6 vs. 4.6 bpm in females, 5.3 vs. 6.0 bpm in males; for Valsalva maneuver, lower Valsalva ratio (OSA vs. control: 1.14 vs. 1.30 in females, 1.29 vs. 1.34 in males, and OSA delay during phase II (0.68 s females/1.31 s males. Heart rate responses showed lower amplitude, delayed onset, and slower rate changes in OSA patients over healthy controls, and impairments may be more pronounced in

  1. Heart rate variability among caregivers of chronically bedridden patients

    Directory of Open Access Journals (Sweden)

    Amrith Pakkala

    2013-01-01

    Full Text Available Background: Caregivers of chronically bedridden patients are likely to suffer from mental and physical exhaustion leading to stress. This is important in view of the prevailing socioeconomic as well as the healthcare system available in a developing country like India. Therefore, the present study is designed to measure heart rate variability (HRV among this special group of population who give care to long-term bedridden patients. Materials and Methods: Fifteen female subjects were enrolled from among attendants of patients admitted with an immediate history of a cerebrovascular accident with locomotor deficits, who required constant care. They were free from any type of physical and mental health issues, nonsmokers and nonaddicts. Each care giver was subjected to HRV analysis on three occasions: The first record was performed in the 1 st week of their arrival in the hospital as caregivers. The second observation was recorded after 3 months of caregiving. The final HRV analysis was done after 6 months of care giving. Two types of parameters were analyzed: Time domain and frequency domain. Statistical analysis was done using paired t-test. Results: Both the HRV parameters: Time and frequency domain, showed decreased values during the 3 rd and 6 th month recording as compared to the 1 st week recording. The decrease is much more during the 6 th month recording as compared to the 3 rd month recording. Statistically significant decrease is observed in mean RR interval, heart rate, very low frequency (VLF, and LF only when the 1 st week recording is compared with the 3 rd month recording, but when the 1 st week recording was compared with the 6 th month recording significant decrease was found in mean RR interval and heart rate. Conclusion: Subjects involved in taking care of chronically ill bedridden patients are likely to undergo a lot of physical and mental stress, thus affecting their autonomic status. HRV analysis using short term

  2. Association between smoking and heart rate variability among individuals with depression.

    Science.gov (United States)

    Harte, Christopher B; Liverant, Gabrielle I; Sloan, Denise M; Kamholz, Barbara W; Rosebrock, Laina E; Fava, Maurizio; Kaplan, Gary B

    2013-08-01

    Both depression and smoking have been independently associated with lower heart rate variability (HRV), suggesting dysregulation of cardiac autonomic function. However, no studies have systematically explored the effects of smoking on HRV among depressed patients. This study examined differences in HRV based on smoking status among depressed individuals. Electrophysiological data were examined among 77 adult outpatients without a history of myocardial infarction, who met criteria for major depressive disorder or dysthymia. Frequency domain [low frequency (LF), high frequency (HF), LF/HF ratio, respiratory sinus arrhythmia (RSA)] parameters of HRV, and heart rate and inter-beat interval (IBI) data were compared between depressed smokers (n = 34) and depressed nonsmokers (n = 44). After controlling for covariates, depressed smokers, compared to depressed nonsmokers, displayed significantly lower LF, HF, and RSA. Among depressed patients, smoking is associated with significantly lower HRV, indicating dysregulated autonomic modulation of the heart.

  3. Reduced dietary sodium intake increases heart rate. A meta-analysis of 63 randomized controlled trials including 72 study populations.

    Directory of Open Access Journals (Sweden)

    Niels eGraudal

    2016-03-01

    Full Text Available Reduced dietary sodium intake (sodium reduction increases heart rate in some studies of animals and humans. As heart rate is independently associated with the development of heart failure and increased risk of premature death a potential increase in heart rate could be a harmful side-effect of sodium reduction. The purpose of the present meta-analysis was to investigate the effect of sodium reduction on heart rate. Relevant studies were retrieved from an updated pool of 176 randomized controlled trials (RCTs published in the period 1973–2014. 63 of the RCTs including 72 study populations reported data on heart rate. In a meta-analysis of these data sodium reduction increased heart rate with 1.65 beats per minute [95% CI: 1.19, 2.11], p < 0.00001, corresponding to 2.4% of the baseline heart rate. This effect was independent of baseline blood pressure. In conclusion sodium reduction increases heart rate by as much (2.4% as it decreases blood pressure (2.5%. This side-effect, which may cause harmful health effects, contributes to the need for a revision of the present dietary guidelines.

  4. Heart rate variability is reduced during acute uncomplicated diverticulitis

    DEFF Research Database (Denmark)

    Huang, Chenxi; Alamili, Mahdi; Rosenberg, Jacob

    2016-01-01

    BACKGROUND: The aim of the present study was to report the trajectory of heart rate variability (HRV) indices during a low-grade acute inflammation and their associations to biomarkers for infection. METHODS: Twelve patients with uncomplicated acute diverticulitis completed this observational study...

  5. Chronic intermittent hypoxia-hypercapnia blunts heart rate responses and alters neurotransmission to cardiac vagal neurons.

    Science.gov (United States)

    Dyavanapalli, Jhansi; Jameson, Heather; Dergacheva, Olga; Jain, Vivek; Alhusayyen, Mona; Mendelowitz, David

    2014-07-01

    Patients with obstructive sleep apnoea experience chronic intermittent hypoxia-hypercapnia (CIHH) during sleep that elicit sympathetic overactivity and diminished parasympathetic activity to the heart, leading to hypertension and depressed baroreflex sensitivity. The parasympathetic control of heart rate arises from pre-motor cardiac vagal neurons (CVNs) located in nucleus ambiguus (NA) and dorsal motor nucleus of the vagus (DMNX). The mechanisms underlying diminished vagal control of heart rate were investigated by studying the changes in blood pressure, heart rate, and neurotransmission to CVNs evoked by acute hypoxia-hypercapnia (H-H) and CIHH. In vivo telemetry recordings of blood pressure and heart rate were obtained in adult rats during 4 weeks of CIHH exposure. Retrogradely labelled CVNs were identified in an in vitro brainstem slice preparation obtained from adult rats exposed either to air or CIHH for 4 weeks. Postsynaptic inhibitory or excitatory currents were recorded using whole cell voltage clamp techniques. Rats exposed to CIHH had increases in blood pressure, leading to hypertension, and blunted heart rate responses to acute H-H. CIHH induced an increase in GABAergic and glycinergic neurotransmission to CVNs in NA and DMNX, respectively; and a reduction in glutamatergic neurotransmission to CVNs in both nuclei. CIHH blunted the bradycardia evoked by acute H-H and abolished the acute H-H evoked inhibition of GABAergic transmission while enhancing glycinergic neurotransmission to CVNs in NA. These changes with CIHH inhibit CVNs and vagal outflow to the heart, both in acute and chronic exposures to H-H, resulting in diminished levels of cardioprotective parasympathetic activity to the heart as seen in OSA patients. © 2014 The Authors. The Journal of Physiology © 2014 The Physiological Society.

  6. Physiological and performance adaptations to an in-season soccer camp in the heat: Associations with heart rate and heart rate variability

    DEFF Research Database (Denmark)

    Buchheit, M; Voss, S C; Nybo, Lars

    2011-01-01

    The aim of the present study was to examine the associations between adaptive responses to an in-season soccer training camp in the heat and changes in submaximal exercising heart rate (HRex, 5-min run at 9 ¿km/h), postexercise HR recovery (HRR) and HR variability (HRV). Fifteen well-trained but ......The aim of the present study was to examine the associations between adaptive responses to an in-season soccer training camp in the heat and changes in submaximal exercising heart rate (HRex, 5-min run at 9 ¿km/h), postexercise HR recovery (HRR) and HR variability (HRV). Fifteen well......-trained but non-heat-acclimatized male adult players performed a training week in Qatar (34.6¿±¿1.9°C wet bulb globe temperature). HRex, HRR, HRV (i.e. the standard deviation of instantaneous beat-to-beat R-R interval variability measured from Poincaré plots SD1, a vagal-related index), creatine kinase (CK...... at the beginning and at the end of the training week. Throughout the intervention, HRex and HRV showed decreasing (P¿...

  7. Prognostic value of ambulatory heart rate revisited in 6928 subjects from 6 populations

    DEFF Research Database (Denmark)

    Hansen, Tine Willum; Thijs, Lutgarde; Staessen, Jan A.

    2008-01-01

    The evidence relating mortality and morbidity to heart rate remains inconsistent. We performed 24-hour ambulatory blood pressure monitoring in 6928 subjects (not on beta-blockers; mean age: 56.2 years; 46.5% women) enrolled in prospective population studies in Denmark, Belgium, Japan, Sweden......, Uruguay, and China. We computed standardized hazard ratios for heart rate, while stratifying for cohort, and adjusting for blood pressure and other cardiovascular risk factors. Over 9.6 years (median), 850, 325, and 493 deaths accrued for total, cardiovascular, and noncardiovascular mortality......, respectively. The incidence of fatal combined with nonfatal end points was 805, 363, 439, and 324 for cardiovascular, stroke, cardiac, and coronary events, respectively. Twenty-four-hour heart rate predicted total (hazard ratio: 1.15) and noncardiovascular (hazard ratio: 1.18) mortality but not cardiovascular...

  8. Heart Rate Variability: New Perspectives on Physiological Mechanisms, Assessment of Self-regulatory Capacity, and Health risk.

    Science.gov (United States)

    McCraty, Rollin; Shaffer, Fred

    2015-01-01

    Heart rate variability, the change in the time intervals between adjacent heartbeats, is an emergent property of interdependent regulatory systems that operates on different time scales to adapt to environmental and psychological challenges. This article briefly reviews neural regulation of the heart and offers some new perspectives on mechanisms underlying the very low frequency rhythm of heart rate variability. Interpretation of heart rate variability rhythms in the context of health risk and physiological and psychological self-regulatory capacity assessment is discussed. The cardiovascular regulatory centers in the spinal cord and medulla integrate inputs from higher brain centers with afferent cardiovascular system inputs to adjust heart rate and blood pressure via sympathetic and parasympathetic efferent pathways. We also discuss the intrinsic cardiac nervous system and the heart-brain connection pathways, through which afferent information can influence activity in the subcortical, frontocortical, and motor cortex areas. In addition, the use of real-time HRV feedback to increase self-regulatory capacity is reviewed. We conclude that the heart's rhythms are characterized by both complexity and stability over longer time scales that reflect both physiological and psychological functional status of these internal self-regulatory systems.

  9. Gonadal hormones and heart rate as an emotional response

    NARCIS (Netherlands)

    de Loos, Wolter Statius

    1988-01-01

    Animai experiments may give information on the physiology of hormones under stress conditions. The model for the investigation of acute emotional stress in animals that has been chosen permits the study of heart rate in freely moving laboratory rats as a sensitive psychophysiological parameter, This

  10. Blood pressure and heart rate adjustment following acute Frenkel's ...

    African Journals Online (AJOL)

    Background: Frenkel's ambulatory activity has been routinely employed by physiotherapists for rehabilitation of gait coordination, however, its immediate influence on blood pressure and heart rate has not been investigated. Objective: To investigate the acute effect of Frenkel's ambulatory activity on blood pressure and ...

  11. Heart Rate and Oxygen Saturation Change Patterns During 6-min Walk Test in Subjects With Chronic Thromboembolic Pulmonary Hypertension.

    Science.gov (United States)

    Inagaki, Takeshi; Terada, Jiro; Yahaba, Misuzu; Kawata, Naoko; Jujo, Takayuki; Nagashima, Kengo; Sakao, Seiichiro; Tanabe, Nobuhiro; Tatsumi, Koichiro

    2017-12-26

    The 6-min walk test (6MWT) is commonly performed to assess functional status in patients with chronic thromboembolic pulmonary hypertension. However, changes in heart rate and oxygen saturation ( S pO 2 ) patterns during 6MWT in patients with chronic thromboembolic pulmonary hypertension remain unclear. Thirty-one subjects with chronic thromboembolic pulmonary hypertension were retrospectively evaluated to examine the relationships between the change in heart rateheart rate), heart rate acceleration time, slope of heart rate acceleration, heart rate recovery during the first minute after 6MWT (HRR1), change in S pO 2 (Δ S pO 2 ), S pO 2 reduction time, and S pO 2 recovery time during 6MWT, and the severity of pulmonary hemodynamics assessed by right heart catheterization and echocardiography. Subjects with severe chronic thromboembolic pulmonary hypertension had significantly longer heart rate acceleration time (144.9 ± 63.9 s vs 96.0 ± 42.5 s, P = .033), lower Δheart rate (47.4 ± 16.9 vs 61.8 ± 13.6 beats, P = .02), and lower HRR1 (13.3 ± 9.0 beats vs 27.1 ± 9.2 beats, P pulmonary hypertension. Subjects with severe chronic thromboembolic pulmonary hypertension also had significantly longer S pO 2 reduction time (178.3 ± 70.3 s vs 134.3 ± 58.4 s, P = .03) and S pO 2 recovery time (107.6 ± 35.3 s vs 69.8 ± 32.7 s, P = .004) than did subjects with mild chronic thromboembolic pulmonary hypertension. Multivariate linear regression analysis showed only mean pulmonary arterial pressure independently was associated with heart rate acceleration time and slope of heart rate acceleration. Heart rate and S pO 2 change patterns during 6MWT is predominantly associated with pulmonary hemodynamics in subjects with chronic thromboembolic pulmonary hypertension. Evaluating heart rate and S pO 2 change patterns during 6MWT may serve a safe and convenient way to follow the change in pulmonary hemodynamics. Copyright © 2017 by Daedalus Enterprises.

  12. A healthy heart is not a metronome: An integrative review of the heart’s anatomy and heart rate variability

    Directory of Open Access Journals (Sweden)

    Fredric Bruce Shaffer

    2014-09-01

    Full Text Available Heart rate variability (HRV, the change in the time intervals between adjacent heartbeats, is an emergent property of interdependent regulatory systems that operate on different time scales to adapt to challenges and achieve optimal performance. This article briefly reviews neural regulation of the heart, and its basic anatomy, the cardiac cycle, and the sinoatrial and atrioventricular pacemakers. The cardiovascular regulation center in the medulla integrates sensory information and input from higher brain centers, and afferent cardiovascular system inputs to adjust heart rate and blood pressure via sympathetic and parasympathetic efferent pathways. This article reviews sympathetic and parasympathetic influences on the heart, and examines the interpretation of HRV and the association between reduced HRV, risk of disease and mortality, and the loss of regulatory capacity. This article also discusses the intrinsic cardiac nervous system and the heart-brain connection, through which afferent information can influence activity in the subcortical and frontocortical areas, and motor cortex. It also considers new perspectives on the putative underlying physiological mechanisms and properties of the ultra-low-frequency (ULF, very-low-frequency (VLF, low-frequency (LF, and high-frequency (HF bands. Additionally, it reviews the most common time and frequency domain measurements as well as standardized data collection protocols. In its final section, this article integrates Porges’ polyvagal theory, Thayer and colleagues’ neurovisceral integration model, Lehrer, Vaschillo, and Vaschillo’s resonance frequency model, and the Institute of HeartMath’s coherence model. The authors conclude that a coherent heart is not a metronome because its rhythms are characterized by both complexity and stability over longer time scales. Future research should expand understanding of how the heart and its intrinsic nervous system influence the brain.

  13. Heart rate variability alters cardiac repolarization and electromechanical dynamics.

    Science.gov (United States)

    Phadumdeo, Vrishti M; Weinberg, Seth H

    2018-04-07

    Heart rate continuously varies due to autonomic regulation, stochasticity in pacemaking, and circadian rhythm, collectively termed heart rate variability (HRV), during normal physiological conditions. Low HRV is clinically associated with an elevated risk of cardiac arrhythmias. Alternans, a beat-to-beat alternation in action potential duration (APD) and/or intracellular calcium (Ca) transient, is a well-known risk factor associated with cardiac arrhythmias that is typically studied under conditions of a constant pacing rate, i.e., the absence of HRV. In this study, we investigate the effects of HRV on the interplay between APD, Ca, and electromechanical properties, employing a nonlinear discrete-time map model that governs APD and intracellular Ca cycling with a stochastic pacing period. We find that HRV can decrease variation in APD and peak Ca at fast pacing rates for which alternans is present. Further, increased HRV typically disrupts the alternating pattern for both APD and peak Ca and weakens the correlation between APD and peak Ca, thus decoupling Ca-mediated instabilities from repolarization alternation. We find that the efficacy of these effects is regulated by the sarcoplasmic reticulum Ca uptake rate. Overall, these results demonstrate that HRV disrupts arrhythmogenic alternans and suggests that HRV may be a significant factor in preventing life-threatening arrhythmias. Copyright © 2018 Elsevier Ltd. All rights reserved.

  14. Validity of a heart rate monitor during work in the laboratory and on the Space Shuttle

    Science.gov (United States)

    Moore, A. D. Jr; Lee, S. M.; Greenisen, M. C.; Bishop, P.

    1997-01-01

    Accurate heart rate measurement during work is required for many industrial hygiene and ergonomics situations. The purpose of this investigation was to determine the validity of heart rate measurements obtained by a simple, lightweight, commercially available wrist-worn heart rate monitor (HRM) during work (cycle exercise) sessions conducted in the laboratory and also during the particularly challenging work environment of space flight. Three different comparisons were made. The first compared HRM data to simultaneous electrocardiogram (ECG) recordings of varying heart rates that were generated by an ECG simulator. The second compared HRM data to ECG recordings collected during work sessions of 14 subjects in the laboratory. Finally, ECG downlink and HRM data were compared in four astronauts who performed cycle exercise during space flight. The data were analyzed using regression techniques. The results were that the HRM recorded virtually identical heart rates compared with ECG recordings for the data set generated by an ECG simulator. The regression equation for the relationship between ECG versus HRM heart rate data during work in the laboratory was: ECG HR = 0.99 x (HRM) + 0.82 (r2 = 0.99). Finally, the agreement between ECG downlink data and HRM data during space flight was also very high, with the regression equation being: Downlink ECG HR = 1.05 x (HRM) -5.71 (r2 = 0.99). The results of this study indicate that the HRM provides accurate data and may be used to reliably obtain valid data regarding heart rate responses during work.

  15. Evaluation of the influence of change in heart rate on left ventricular diastolic function indices

    International Nuclear Information System (INIS)

    Kimura, Motomasa; Yamagishi, Hiroaki; Seino, Yasuyuki; Odano, Ikuo; Sakai, Kunio; Yamamoto, Tomohiko; Tsuda, Takashi

    1988-01-01

    In order to assess the influence of change in heart rate on left ventricular diastolic function indices, ECG gated cardiac pool study was performed in 6 patients with implanted programmable AAI pacemakers. Heart rate was changed by atrial pacing from 50 to 120 beats/min, every 10 beats/min. The filling fraction during first third of diastole (1/3FF), the peak filling rate (PFR), mean first third filling rate (1/3FR-mean) and early filling volume ratio (%EFV), being used as the indices of left ventricular diastolic performance, were assessed. In accordance with increase in heart rate, 1/3FF decreased significantly. PFR were fairly stable from 50 to 80 beats/min, but increased significantly from 90 to 120 beats/min. 1/3FR-mean and %EFV did not change significantly, but 1/3FR-mean showed decreasing tendency and %EFV showed increasing tendency as the heart rate was increased. %EFV was more changeable index than other indices among clinical cases. These results indicate that PFR and 1/3FR-mean were appropriate diastolic phase indices at rest. (author)

  16. Paradoxical dissociation between heart rate and heart rate variability following different modalities of exercise in individuals with metabolic syndrome: The RESOLVE study.

    Science.gov (United States)

    Boudet, Gil; Walther, Guillaume; Courteix, Daniel; Obert, Philippe; Lesourd, Bruno; Pereira, Bruno; Chapier, Robert; Vinet, Agnès; Chamoux, Alain; Naughton, Geraldine; Poirier, Paul; Dutheil, Frédéric

    2017-02-01

    Aims To analyse the effects of different modalities of exercise training on heart rate variability (HRV) in individuals with metabolic syndrome (MetS). Methods and results Eighty MetS participants (aged 50-70 years) were housed and managed in an inpatient medical centre for 21 days, including weekends. Physical activity and food intake/diet were intensively monitored. Participants were randomly assigned into three training groups, differing only by intensity of exercise: moderate-endurance-moderate-resistance ( re), high-resistance-moderate-endurance ( Re), and moderate-resistance-high-endurance ( rE). HRV was recorded before and after the intervention by 24-hour Holter electrocardiogram. Although mean 24-hour heart rate decreased more in Re than re (-11.6 ± 1.6 vs. -4.8 ± 2.1%; P = 0.010), low frequency/high frequency decreased more in re than Re (-20.4 ± 5.5% vs. + 20.4 ± 9.1%; P = 0.002) and rE (-20.4 ± 5.5% vs. -0.3 ± 11.1%; P = 0.003). Very low frequency increased more in Re than re (+121.2 ± 35.7 vs. 42.9 ± 11.3%; P = 0.004). For all HRV parameters, rE ranged between re and Re values. Low frequency/high frequency changes were linked with visceral fat loss only in re (coefficient 5.9, 95% CI 1.9-10.0; P = 0.004). By day 21, HRV parameters of MetS groups (heart rate -8.6 ± 1.0%, standard deviation of R-R intervals + 34.0 ± 6.6%, total power + 63.3 ± 11.1%; P < 0.001) became closer to values of 50 aged-matched healthy controls. Conclusions A 3-week residential programme with intensive volumes of physical activity (15-20 hours per week) enhanced HRV in individuals with MetS. Participants with moderate intensity of training had greater improvements in sympathovagal balance, whereas those with high intensity in resistance training had greater decreases in heart rate and greater increases in very low frequency. Modality-specific relationships were observed between enhanced HRV

  17. National trends in heart failure hospitalization rates in Slovenia 2004-2012.

    Science.gov (United States)

    Omersa, Daniel; Farkas, Jerneja; Erzen, Ivan; Lainscak, Mitja

    2016-11-01

    Heart failure (HF) hospitalization rates are decreasing in western Europe, but little is known about trends in central and east European countries. We analysed the Slovenian national hospitalization database to determine the burden of HF hospitalization. The Slovenian National Hospital Discharge Registry was searched for HF hospitalizations between 2004 and 2012 in patients aged ≥20 years. A total of 55 531 main HF hospitalizations (43 636 first HF hospitalizations) in 34 406 patients (median age 78 years, 55% female) were recorded. The most common co-morbidities were arterial hypertension (54.3%), atrial fibrillation (40.6%), diabetes mellitus (24.5%), and ischaemic heart disease (21.9%). The number of age-standardized main and first HF hospitalizations per 100 000 population decreased from 249 to 232 (7.1%, P = 0.002) and from 467 to 435 (6.8%, P = 0.074), respectively. Crude main and first HF hospitalization rates increased from 249 to 298 (19.8%, P Slovenia, standardized HF hospitalization rates have decreased but the crude HF hospitalization burden has increased. Readmissions were associated with established cardiovascular risk factors. © 2016 The Authors. European Journal of Heart Failure © 2016 European Society of Cardiology.

  18. Structural characterization of the Man5 glycoform of human IgG3 Fc

    Energy Technology Data Exchange (ETDEWEB)

    Shah, Ishan S.; Lovell, Scott; Mehzabeen, Nurjahan; Battaile, Kevin P.; Tolbert, Thomas J. (Kansas); (HWMRI)

    2017-12-01

    Immunoglobulin G (IgG) consists of four subclasses in humans: IgG1, IgG2, IgG3 and IgG4, which are highly conserved but have unique differences that result in subclass-specific effector functions. Though IgG1 is the most extensively studied IgG subclass, study of other subclasses is important to understand overall immune function and for development of new therapeutics. When compared to IgG1, IgG3 exhibits a similar binding profile to Fcγ receptors and stronger activation of complement. All IgG subclasses are glycosylated at N297, which is required for Fcγ receptor and C1q complement binding as well as maintaining optimal Fc conformation. We have determined the crystal structure of homogenously glycosylated human IgG3 Fc with a GlcNAc2Man5 (Man5) high mannose glycoform at 1.8 Å resolution and compared its structural features with published structures from the other IgG subclasses. Although the overall structure of IgG3 Fc is similar to that of other subclasses, some structural perturbations based on sequence differences were revealed. For instance, the presence of R435 in IgG3 (and H435 in the other IgG subclasses) has been implicated to result in IgG3-specific properties related to binding to protein A, protein G and the neonatal Fc receptor (FcRn). The IgG3 Fc structure helps to explain some of these differences. Additionally, protein-glycan contacts observed in the crystal structure appear to correlate with IgG3 affinity for Fcγ receptors as shown by binding studies with IgG3 Fc glycoforms. Finally, this IgG3 Fc structure provides a template for further studies aimed at engineering the Fc for specific gain of function.

  19. Heart rate and flow velocity variability as determined from umbilical Doppler velocimetry at 10-20 weeks of gestation.

    Science.gov (United States)

    Ursem, N T; Struijk, P C; Hop, W C; Clark, E B; Keller, B B; Wladimiroff, J W

    1998-11-01

    1. The aim of this study was to define from umbilical artery flow velocity waveforms absolute peak systolic and time-averaged velocity, fetal heart rate, fetal heart rate variability and flow velocity variability, and the relation between fetal heart rate and velocity variables in early pregnancy.2.A total of 108 women presenting with a normal pregnancy from 10 to 20 weeks of gestation consented to participate in a cross-sectional study design. Doppler ultrasound recordings were made from the free-floating loop of the umbilical cord.3. Umbilical artery peak systolic and time-averaged velocity increased at 10-20 weeks, whereas fetal heart rate decreased at 10-15 weeks of gestation and plateaued thereafter. Umbilical artery peak systolic velocity variability and fetal heart rate variability increased at 10-20 and 15-20 weeks respectively.4. The inverse relationship between umbilical artery flow velocity and fetal heart rate at 10-15 weeks of gestation suggests that the Frank-Starling mechanism regulates cardiovascular control as early as the late first and early second trimesters of pregnancy. A different underlying mechanism is suggested for the observed variability profiles in heart rate and umbilical artery peak systolic velocity. It is speculated that heart rate variability is mediated by maturation of the parasympathetic nervous system, whereas peak systolic velocity variability reflects the activation of a haemodynamic feedback mechanism.

  20. Heart rate reveals torpor at high body temperatures in lowland tropical free-tailed bats.

    Science.gov (United States)

    O'Mara, M Teague; Rikker, Sebastian; Wikelski, Martin; Ter Maat, Andries; Pollock, Henry S; Dechmann, Dina K N

    2017-12-01

    Reduction in metabolic rate and body temperature is a common strategy for small endotherms to save energy. The daily reduction in metabolic rate and heterothermy, or torpor, is particularly pronounced in regions with a large variation in daily ambient temperature. This applies most strongly in temperate bat species (order Chiroptera), but it is less clear how tropical bats save energy if ambient temperatures remain high. However, many subtropical and tropical species use some daily heterothermy on cool days. We recorded the heart rate and the body temperature of free-ranging Pallas' mastiff bats ( Molossus molossus ) in Gamboa, Panamá, and showed that these individuals have low field metabolic rates across a wide range of body temperatures that conform to high ambient temperature. Importantly, low metabolic rates in controlled respirometry trials were best predicted by heart rate, and not body temperature . Molossus molossus enter torpor-like states characterized by low metabolic rate and heart rates at body temperatures of 32°C, and thermoconform across a range of temperatures. Flexible metabolic strategies may be far more common in tropical endotherms than currently known.

  1. Wavelet and receiver operating characteristic analysis of heart rate variability

    Science.gov (United States)

    McCaffery, G.; Griffith, T. M.; Naka, K.; Frennaux, M. P.; Matthai, C. C.

    2002-02-01

    Multiresolution wavelet analysis has been used to study the heart rate variability in two classes of patients with different pathological conditions. The scale dependent measure of Thurner et al. was found to be statistically significant in discriminating patients suffering from hypercardiomyopathy from a control set of normal subjects. We have performed Receiver Operating Characteristc (ROC) analysis and found the ROC area to be a useful measure by which to label the significance of the discrimination, as well as to describe the severity of heart dysfunction.

  2. Comparative studies on Fc receptors for IgG on resting and activated T lymphocytes

    International Nuclear Information System (INIS)

    Hueckel, C.; Jensen, H.L.; Rychly, J.; Sandor, M.; Erdei, A.; Gergely, J.

    1986-01-01

    Fc-receptors for IgG (FcγR) on resting (i.e. freshly prepared) and mitogen (Con A) or alloantigen-activated mouse spleen T cells were compared using binding of different markers such as 125 I-labelled immune complexes, 125 I-labelled anti FcγR monoclonal antibody, FITC-labelled aggr. IgG and sheep erythrocytes covered with specific antibody (EA rosetting). C3b receptors were detected by rosetting with sheep erythrocytes covered with antibody and complement (EAC rosetting). The electrophoretic mobility of the cells without or after binding of aggr. IgG was also tested. Differences between resting and activated T cells were found: (1) After activation of T cells by mitogen or alloantigen, a proportion of FcγR-positive cells increased two to four times. (2) FcγR number per FcγR-positive cell seemed to be higher on activated then on resting cells. (3) FcγR-positive resting cells did not shed their FcγR upon incubation at 4 0 C followed by incubation at 37 0 C, but FcγR-positive activated cells shed a remarkable proportion of their FcγR on the same conditions. (4) Binding of aggr. IgG caused a decrease of electrophoretic mobility of activated but not resting cells. (5) FcγR-positive resting cells were also C3b receptor-positive, whereas FcγR-positive activated cells had no detectable C3b receptors. (author)

  3. Attenuated heart rate response is associated with hypocretin deficiency in patients with narcolepsy.

    Science.gov (United States)

    Sorensen, Gertrud Laura; Knudsen, Stine; Petersen, Eva Rosa; Kempfner, Jacob; Gammeltoft, Steen; Sorensen, Helge Bjarup Dissing; Jennum, Poul

    2013-01-01

    Several studies have suggested that hypocretin-1 may influence the cerebral control of the cardiovascular system. We analyzed whether hypocretin-1 deficiency in narcolepsy patients may result in a reduced heart rate response. We analyzed the heart rate response during various sleep stages from a 1-night polysomnography in patients with narcolepsy and healthy controls. The narcolepsy group was subdivided by the presence of +/- cataplexy and +/- hypocretin-1 deficiency. Sleep laboratory studies conducted from 2001-2011. In total 67 narcolepsy patients and 22 control subjects were included in the study. Cataplexy was present in 46 patients and hypocretin-1 deficiency in 38 patients. None. All patients with narcolepsy had a significantly reduced heart rate response associated with arousals and leg movements (P hypocretin-1 deficiency and cataplexy groups compared with patients with normal hypocretin-1 levels (P hypocretin-1 deficiency significantly predicted the heart rate response associated with arousals in both REM and non-REM in a multivariate linear regression. Our results show that autonomic dysfunction is part of the narcoleptic phenotype, and that hypocretin-1 deficiency is the primary predictor of this dysfunction. This finding suggests that the hypocretin system participates in the modulation of cardiovascular function at rest.

  4. Randomized controlled trial of relaxation music to reduce heart rate in patients undergoing cardiac CT.

    Science.gov (United States)

    Ng, Ming Yen; Karimzad, Yasser; Menezes, Ravi J; Wintersperger, Bernd J; Li, Qin; Forero, Julian; Paul, Narinder S; Nguyen, Elsie T

    2016-10-01

    To evaluate the heart rate lowering effect of relaxation music in patients undergoing coronary CT angiography (CCTA), pulmonary vein CT (PVCT) and coronary calcium score CT (CCS). Patients were randomised to a control group (i.e. standard of care protocol) or to a relaxation music group (ie. standard of care protocol with music). The groups were compared for heart rate, radiation dose, image quality and dose of IV metoprolol. Both groups completed State-Trait Anxiety Inventory anxiety questionnaires to assess patient experience. One hundred and ninety-seven patients were recruited (61.9 % males); mean age 56y (19-86 y); 127 CCTA, 17 PVCT, 53 CCS. No significant difference in heart rate, radiation dose, image quality, metoprolol dose and anxiety scores. 86 % of patients enjoyed the music. 90 % of patients in the music group expressed a strong preference to have music for future examinations. The patient cohort demonstrated low anxiety levels prior to CT. Relaxation music in CCTA, PVCT and CCS does not reduce heart rate or IV metoprolol use. Patients showed low levels of anxiety indicating that anxiolytics may not have a significant role in lowering heart rate. Music can be used in cardiac CT to improve patient experience. • Relaxation music does not reduce heart rate in cardiac CT • Relaxation music does not reduce beta-blocker use in cardiac CT • Relaxation music has no effect on cardiac CT image quality • Low levels of anxiety are present in patients prior to cardiac CT • Patients enjoyed the relaxation music and this results in improved patient experience.

  5. Ivabradine in acute coronary syndromes: Protection beyond heart rate lowering.

    Science.gov (United States)

    Niccoli, Giampaolo; Borovac, Josip Anđelo; Vetrugno, Vincenzo; Camici, Paolo G; Crea, Filippo

    2017-06-01

    Ivabradine is a heart rate reducing agent that exhibits anti-ischemic effects through the inhibition of funny electrical current in the sinus node resulting in heart rate reduction, thus enabling longer diastolic perfusion time, and reduced myocardial oxygen consumption without detrimental changes in arterial blood pressure, coronary vasomotion, and ventricular contractility. The current guideline-based clinical use of Ivabradine is reserved for patients with stable angina pectoris who cannot tolerate or whose symptoms are inadequately controlled with beta blockers. In patients with chronic heart failure and reduced ejection fraction, Ivabradine has demonstrated beneficial effects in improving clinical outcomes when added to conventional therapy. However, the role of Ivabradine in acute coronary syndromes has not been established. Based on the results from some relevant preclinical studies and a limited amount of clinical data that were reported recently, the role of Ivabradine in acute ischemic events warrants further investigation. The aim of this review is to provide an overview of the available literature on the potential role of Ivabradine in the clinical context of acute coronary syndromes. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Features of Heart Rate Variability Capture Regulatory Changes During Kangaroo Care in Preterm Infants.

    Science.gov (United States)

    Kommers, Deedee R; Joshi, Rohan; van Pul, Carola; Atallah, Louis; Feijs, Loe; Oei, Guid; Bambang Oetomo, Sidarto; Andriessen, Peter

    2017-03-01

    To determine whether heart rate variability (HRV) can serve as a surrogate measure to track regulatory changes during kangaroo care, a period of parental coregulation distinct from regulation within the incubator. Nurses annotated the starting and ending times of kangaroo care for 3 months. The pre-kangaroo care, during-kangaroo care, and post-kangaroo care data were retrieved in infants with at least 10 accurately annotated kangaroo care sessions. Eight HRV features (5 in the time domain and 3 in the frequency domain) were used to visually and statistically compare the pre-kangaroo care and during-kangaroo care periods. Two of these features, capturing the percentage of heart rate decelerations and the extent of heart rate decelerations, were newly developed for preterm infants. A total of 191 kangaroo care sessions were investigated in 11 preterm infants. Despite clinically irrelevant changes in vital signs, 6 of the 8 HRV features (SD of normal-to-normal intervals, root mean square of the SD, percentage of consecutive normal-to-normal intervals that differ by >50 ms, SD of heart rate decelerations, high-frequency power, and low-frequency/high-frequency ratio) showed a visible and statistically significant difference (P heart rate decelerations. HRV-based features may be clinically useful for capturing the dynamic changes in autonomic regulation in response to kangaroo care and other changes in environment and state. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Randomized controlled trial of relaxation music to reduce heart rate in patients undergoing cardiac CT

    Energy Technology Data Exchange (ETDEWEB)

    Ng, Ming Yen [University of Toronto, Department of Medical Imaging, Toronto General Hospital, Toronto, ON (Canada); The University of Hong Kong, Queen Mary Hospital, Department of Diagnostic Radiology, Hong Kong (China); Karimzad, Yasser; Menezes, Ravi J.; Wintersperger, Bernd J.; Li, Qin; Forero, Julian; Paul, Narinder S.; Nguyen, Elsie T. [University of Toronto, Department of Medical Imaging, Toronto General Hospital, Toronto, ON (Canada)

    2016-10-15

    To evaluate the heart rate lowering effect of relaxation music in patients undergoing coronary CT angiography (CCTA), pulmonary vein CT (PVCT) and coronary calcium score CT (CCS). Patients were randomised to a control group (i.e. standard of care protocol) or to a relaxation music group (ie. standard of care protocol with music). The groups were compared for heart rate, radiation dose, image quality and dose of IV metoprolol. Both groups completed State-Trait Anxiety Inventory anxiety questionnaires to assess patient experience. One hundred and ninety-seven patients were recruited (61.9 % males); mean age 56y (19-86 y); 127 CCTA, 17 PVCT, 53 CCS. No significant difference in heart rate, radiation dose, image quality, metoprolol dose and anxiety scores. 86 % of patients enjoyed the music. 90 % of patients in the music group expressed a strong preference to have music for future examinations. The patient cohort demonstrated low anxiety levels prior to CT. Relaxation music in CCTA, PVCT and CCS does not reduce heart rate or IV metoprolol use. Patients showed low levels of anxiety indicating that anxiolytics may not have a significant role in lowering heart rate. Music can be used in cardiac CT to improve patient experience. (orig.)

  8. Randomized controlled trial of relaxation music to reduce heart rate in patients undergoing cardiac CT

    International Nuclear Information System (INIS)

    Ng, Ming Yen; Karimzad, Yasser; Menezes, Ravi J.; Wintersperger, Bernd J.; Li, Qin; Forero, Julian; Paul, Narinder S.; Nguyen, Elsie T.

    2016-01-01

    To evaluate the heart rate lowering effect of relaxation music in patients undergoing coronary CT angiography (CCTA), pulmonary vein CT (PVCT) and coronary calcium score CT (CCS). Patients were randomised to a control group (i.e. standard of care protocol) or to a relaxation music group (ie. standard of care protocol with music). The groups were compared for heart rate, radiation dose, image quality and dose of IV metoprolol. Both groups completed State-Trait Anxiety Inventory anxiety questionnaires to assess patient experience. One hundred and ninety-seven patients were recruited (61.9 % males); mean age 56y (19-86 y); 127 CCTA, 17 PVCT, 53 CCS. No significant difference in heart rate, radiation dose, image quality, metoprolol dose and anxiety scores. 86 % of patients enjoyed the music. 90 % of patients in the music group expressed a strong preference to have music for future examinations. The patient cohort demonstrated low anxiety levels prior to CT. Relaxation music in CCTA, PVCT and CCS does not reduce heart rate or IV metoprolol use. Patients showed low levels of anxiety indicating that anxiolytics may not have a significant role in lowering heart rate. Music can be used in cardiac CT to improve patient experience. (orig.)

  9. Toxicity of aerosol propellants in the respiratory and circulatory systems. VII. Influence of pulmonary emphysema and anesthesia in the rat.

    Science.gov (United States)

    Watanabe, T; Aviado, D M

    1975-01-01

    Experimental induction of pulmonary emphysema caused an increase in sensitivity of the rat to toxicity from inhalation of propellants. The emphysematous rat showed an exaggerated reduction in pulmonary compliance in response to inhalation of trichlorofluoromethane (FC 11). In emphysematous and non emphysematous rats without anesthesia the inhalation of FC 11 caused tachycardia, arrhythmias and other abnormalities in the electrocardiogram. The tachycardiac response was eliminated by induction of barbiturate anesthesia, which increased the sensitivity of the heart to occurrence of abnormalities in the electrocardiogram in response to inhalation of FC 11 as well as of dichlorodifluoromethane (FC 12) and difluoroethane (FC 152a). The acceleration in heart rate in response to inhalation of FC 11, hypoxia or hypercapnea was prevented by prior treatment with a beta-blocking drug.

  10. 21 CFR 866.5530 - Immunoglobulin G (Fc fragment specific) immunological test system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Immunoglobulin G (Fc fragment specific... Test Systems § 866.5530 Immunoglobulin G (Fc fragment specific) immunological test system. (a) Identification. An immunoglobulin G (Fc fragment specific) immunological test system is a device that consists of...

  11. Influence of peak exercise heart rate on normal thallium-201 myocardial clearance

    International Nuclear Information System (INIS)

    Kaul, S.; Chesler, D.A.; Pohost, G.M.; Strauss, H.W.; Okada, R.D.; Boucher, C.A.

    1986-01-01

    Measurement of myocardial clearance rates between initial and delayed images is a major justification for adding computer quantification to the interpretation of exercise 201 TI images. To clarify the range of normal thallium clearance and its relationship to the level of exercise achieved, exercise thallium images in 89 normal subjects were analyzed: 45 asymptomatic subjects with less than 1% probability of coronary artery disease (CAD) (Group I), and 44 patients with chest pain found to have no significant CAD on angiography (Group II). Mean initial regional thallium uptake was similar in the two groups, but myocardial thallium clearance (mean +/- 1 s.d.) was slower in Group II, expressed as a longer half-life in the myocardium (8.2 +/- 7.6 hr compared with 3.4 +/- 0.7 hr p less than 0.001). Analysis of variance using ten clinical and exercise variables as covariates showed that the slower clearance in Group II was related to a lower peak exercise heart rate (HR) (154 +/- 27 compared with 183 +/- 11, respectively, p less than 0.001). By linear regression analysis, a decrease in peak HR of 1 beat/min was associated with a slower thallium clearance (longer half-life) of 0.05 hr. Using this formula, the clearance value in each patient was then corrected for peak exercise heart rate by decreasing measured clearance by 0.05 hr multiplied by the amount peak exercise heart rate which was below 183 (the mean value in Group I). There were no differences in the corrected clearance between the two groups. We conclude that thallium myocardial clearance after exercise is related in part to factors other than the presence of CAD, being slower when peak exercise HR is lower. Therefore, thallium clearance rates alone uncorrected for peak exercise heart rate should be used with caution when diagnosing CAD

  12. Quantifying the Interactions between Maternal and Fetal Heart Rates by Transfer Entropy.

    Directory of Open Access Journals (Sweden)

    Faezeh Marzbanrad

    Full Text Available Evidence of the short term relationship between maternal and fetal heart rates has been found in previous studies. However there is still limited knowledge about underlying mechanisms and patterns of the coupling throughout gestation. In this study, Transfer Entropy (TE was used to quantify directed interactions between maternal and fetal heart rates at various time delays and gestational ages. Experimental results using maternal and fetal electrocardiograms showed significant coupling for 63 out of 65 fetuses, by statistically validating against surrogate pairs. Analysis of TE showed a decrease in transfer of information from fetus to the mother with gestational age, alongside the maturation of the fetus. On the other hand, maternal to fetal TE was significantly greater in mid (26-31 weeks and late (32-41 weeks gestation compared to early (16-25 weeks gestation (Mann Whitney Wilcoxon (MWW p<0.05. TE further increased from mid to late, for the fetuses with RMSSD of fetal heart rate being larger than 4 msec in the late gestation. This difference was not observed for the fetuses with smaller RMSSD, which could be associated with the quiet sleep state. Delay in the information transfer from mother to fetus significantly decreased (p = 0.03 from mid to late gestation, implying a decrease in fetal response time. These changes occur concomitant with the maturation of the fetal sensory and autonomic nervous systems with advancing gestational age. The effect of maternal respiratory rate derived from maternal ECG was also investigated and no significant relationship was found between breathing rate and TE at any lag. In conclusion, the application of TE with delays revealed detailed information on the fetal-maternal heart rate coupling strength and latency throughout gestation, which could provide novel clinical markers of fetal development and well-being.

  13. Temporal discounting and heart rate reactivity to stress.

    Science.gov (United States)

    Diller, James W; Patros, Connor H G; Prentice, Paula R

    2011-07-01

    Temporal discounting is the reduction of the value of a reinforcer as a function of increasing delay to its presentation. Impulsive individuals discount delayed consequences more rapidly than self-controlled individuals, and impulsivity has been related to substance abuse, gambling, and other problem behaviors. A growing body of literature has identified biological correlates of impulsivity, though little research to date has examined relations between delay discounting and markers of poor health (e.g., cardiovascular reactivity to stress). We evaluated the relation between one aspect of impulsivity, measured using a computerized temporal discounting task, and heart rate reactivity, measured as a change in heart rate from rest during a serial subtraction task. A linear regression showed that individuals who were more reactive to stress responded more impulsively (i.e., discounted delayed reinforcers more rapidly). When results were stratified by gender, the effect was observed for females, but not for males. This finding supports previous research on gender differences in cardiovascular reactivity and suggests that this type of reactivity may be an important correlate of impulsive behavior. Copyright © 2011 Elsevier B.V. All rights reserved.

  14. Tracking the maximum efficiency point for the FC system based on extremum seeking scheme to control the air flow

    International Nuclear Information System (INIS)

    Bizon, Nicu

    2014-01-01

    Highlights: • The Maximum Efficiency Point (MEP) is tracked based on air flow rate. • The proposed Extremum Seeking (ES) control assures high performances. • About 10 kW/s search speed and 99.99% stationary accuracy can be obtained. • The energy efficiency increases with 3–12%, according to the power losses. • The control strategy is robust based on self-optimizing ES scheme proposed. - Abstract: An advanced control of the air compressor for the Proton Exchange Membrane Fuel Cell (PEMFC) system is proposed in this paper based on Extremum Seeking (ES) control scheme. The FC net power is mainly depended on the air and hydrogen flow rate and pressure, and heat and water management. This paper proposes to compute the optimal value for the air flow rate based on the advanced ES control scheme in order to maximize the FC net power. In this way, the Maximum Efficiency Point (MEP) will be tracked in real time, with about 10 kW/s search speed and a stationary accuracy of 0.99. Thus, energy efficiency will be close to the maximum value that can be obtained for a given PEMFC stack and compressor group under dynamic load. It is shown that the MEP tracking allows an increasing of the FC net power with 3–12%, depending on the percentage of the FC power supplied to the compressor and the level of the load power. Simulations shows that the performances mentioned above are effective

  15. Heart rate variability | Lutfi | Sudan Journal of Medical Sciences

    African Journals Online (AJOL)

    An important outcome of such analysis is heart rate variability (HRV), which is widely accepted to have prognostic significance in patients with cardiovascular diseases especially after acute myocardial infarction. This is because HRV represents one of the most helpful markers of autonomic balance and hence can predict ...

  16. Improved detection of congestive heart failure via probabilistic symbolic pattern recognition and heart rate variability metrics.

    Science.gov (United States)

    Mahajan, Ruhi; Viangteeravat, Teeradache; Akbilgic, Oguz

    2017-12-01

    A timely diagnosis of congestive heart failure (CHF) is crucial to evade a life-threatening event. This paper presents a novel probabilistic symbol pattern recognition (PSPR) approach to detect CHF in subjects from their cardiac interbeat (R-R) intervals. PSPR discretizes each continuous R-R interval time series by mapping them onto an eight-symbol alphabet and then models the pattern transition behavior in the symbolic representation of the series. The PSPR-based analysis of the discretized series from 107 subjects (69 normal and 38 CHF subjects) yielded discernible features to distinguish normal subjects and subjects with CHF. In addition to PSPR features, we also extracted features using the time-domain heart rate variability measures such as average and standard deviation of R-R intervals. An ensemble of bagged decision trees was used to classify two groups resulting in a five-fold cross-validation accuracy, specificity, and sensitivity of 98.1%, 100%, and 94.7%, respectively. However, a 20% holdout validation yielded an accuracy, specificity, and sensitivity of 99.5%, 100%, and 98.57%, respectively. Results from this study suggest that features obtained with the combination of PSPR and long-term heart rate variability measures can be used in developing automated CHF diagnosis tools. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Effects and after-effects of chewing gum on vigilance, heart rate, EEG and mood.

    Science.gov (United States)

    Allen, Andrew P; Jacob, Tim J C; Smith, Andrew P

    2014-06-22

    Research has shown that chewing gum improves attention, although the mechanism for this effect remains unclear. This study investigated the effects and after-effects of chewing gum on vigilance, mood, heart rate and EEG. Participants completed a vigilance task four times; at baseline, with or without chewing gum, and twice post-chewing. EEG alpha and beta power at left frontal and temporal lobes, subjective mood and heart rate were assessed. Chewing gum shortened reaction time and increased the rate of hits, although hits fell during the second post-chewing task. Chewing gum heightened heart rate, but only during chewing. Gum also increased beta power at F7 and T3 immediately post-chewing, but not following the post-chewing tasks. The findings show that chewing gum affects several different indicators of alertness. Copyright © 2014 Elsevier Inc. All rights reserved.

  18. Identification of heart rate-associated loci and their effects on cardiac conduction and rhythm disorders

    NARCIS (Netherlands)

    den Hoed, M.A.H.; Eijgelsheim, M.; Esko, T.; Brundel, B.J.; Peal, D.S.; Evans, D.M.; Nolte, I.M.; Segrè, A.V.; Holm, H.; Handsaker, R.E.; Westra, H.J.; Johnson, T.; Isaacs, A.; Yang, L.; Lundby, A.; Zhao, J.H.; Kim, Y.J.; Go, M.J.; Almgren, P.; Bochud, M.; Boucher, G.; Cornelis, M.C.; Gudbjartsson, D.F.; Hadley, D.; van der Harst, P.; Hayward, C.; den Heijer, M.; Igl, W.; Jackson, A.U.; Kutalik, Z.; Luan, J.; Kemp, J.P.; Kristiansson, K.; Ladenvall, C.; Lorentzon, M.; Montasser, M.E.; Njajou, O.T.; O'Reilly, P.F.; Padmanabhan, S.; St Pourcain, B.; Rankinen, T.; Salo, P.; Tanaka, T.; Timpson, N.J.; Vitart, V.; Waite, L.; Wheeler, W.; Zhang, W.; Draisma, H.H.M.; Feitosa, M.F.; Kerr, K.F.; Lind, P.A.; Mihailov, E.; Onland-Moret, N.C.; Song, C.; Weedon, M.N.; Xie, W.; Yengo, L.; Absher, D.; Albert, C.M.; Alonso, A.; Arking, D.E.; de Bakker, P.I.; Balkau, B.; Barlassina, C.; Benaglio, P.; Bis, J.C.; Bouatia-Naji, N.; Brage, S.; Chanock, S.J.; Chines, P.S.; Chung, M.; Darbar, D.; Dina, C.; Dörr, M.; Elliott, P.; Felix, S.B.; Fischer, K.; Fuchsberger, C.; de Geus, E.J.C.; Goyette, P.; Gudnason, V.; Harris, T.B.; Hartikainen, A.L.; Havulinna, A.S.; Heckbert, S.R.; Hicks, A.A.; Hofman, A.; Holewijn, S.; Hoogstra-Berends, F.; Hottenga, J.J.; Jensen, M.K.; Johansson, A.; Junttila, J.; Kääb, S.; Kanon, B.; Ketkar, S.; Khaw, K.T.; Knowles, J.W.; Kooner, A.S.; Kors, J.A.; Kumari, M.; Milani, L.; Laiho, P.; Lakatta, E.G.; Langenberg, C.; Leusink, M.; Liu, Y.; Luben, R.N.; Lunetta, K.L.; Lynch, S.N.; Markus, M.R.; Marques-Vidal, P.; Mateo Leach, I.; McArdle, W.L.; McCarroll, S.A.; Medland, S.E.; Miller, K.A.; Montgomery, G.W.; Morrison, A.C.; Müller-Nurasyid, M.; Navarro, P.; Nelis, M.; O'Connell, J.R.; O'Donnell, C.J.; Ong, K.K.; Newman, A.B.; Peters, A.; Polasek, O.; Pouta, A.; Pramstaller, P.P.; Psaty, B.M.; Rao, D.C.; Ring, S.M.; Rossin, E.J.; Rudan, D.; Sanna, S.; Scott, R.A.; Sehmi, J.S.; Sharp, S.; Shin, J.T.; Singleton, A.B.; Smith, A.V.; Soranzo, N.; Spector, T.D.; Stewart, C.; Stringham, H.M.; Tarasov, K.V.; Uitterlinden, A.G.; Vandenput, L.; Hwang, S.J.; Whitfield, J.B.; Wijmenga, C.; Wild, S.H.; Willemsen, G.; Wilson, J.F.; Witteman, J.C.; Wong, A.; Wong, Q.; Jamshidi, Y.; Zitting, P.; Boer, J.M.; Boomsma, D.I.; Borecki, I.B.; van Duijn, C.M.; Ekelund, U.; Forouhi, N.G.; Froguel, P.; Hingorani, A.D.; Ingelsson, E.; Kivimaki, M.; Kronmal, R.A.; Kuh, D; Lind, L.; Martin, N.G.; Oostra, B.A.; Pedersen, N.L.; Quertermous, T.; Rotter, J.I.; van der Schouw, Y.T.; Verschuren, W.M.; Walker, M.; Albanes, D.; Arnar, D.O.; Assimes, T.L.; Bandinelli, S.; Boehnke, M.; de Boer, R.A.; Bouchard, C.; Caulfield, W.L.; Chambers, J.C.; Curhan, G.; Cusi, D.; Eriksson, J.; Ferrucci, L.; van Gilst, W.H.; Glorioso, N.; de Graaf, J.; Groop, L.; Gyllensten, U.; Hsueh, W.C.; Hu, F.B.; Huikuri, H.V.; Hunter, D.J.; Iribarren, C.; Isomaa, B.; Järvelin, M.R.; Jula, A.; Kähönen, M.; Kiemeney, L.A.; van der Klauw, M.M.; Kooner, J.S.; Kraft, P.; Iacoviello, L.; Lehtimäki, T.; Lokki, M.L.; Mitchell, B.D.; Navis, G.; Nieminen, M.S.; Ohlsson, C.; Poulter, N.R.; Qi, L.; Raitakari, O.T.; Rimm, E.B.; Rioux, J.D.; Rizzi, F.; Rudan, I.; Salomaa, V.; Sever, P.S.; Shields, D.C.; Shuldiner, A.R.; Sinisalo, J.; Stanton, A.V.; Stolk, R.P.; Strachan, D.P.; Tardif, J.C.; Thorsteinsdottir, U.; Tuomilehto, J.; van Veldhuisen, D.J.; Virtamo, J.; Viikari, J.; Vollenweider, P.; Waeber, G.; Widen, E.; Cho, Y.S.; Olsen, J.V.; Visscher, P.M.; Willer, C.J.; Franke, L; Erdmann, J.; Thompson, J.R.; Pfeufer, A.; Sotoodehnia, N.; Newton-Cheh, C.; Ellinor, P.T.; Stricker, B.H.C.; Metspalu, A.; Perola, M.; Beckmann, J.S.; Smith, G.D.; Stefansson, K.; Wareham, N.J.; Munroe, P.B.; Sibon, O.C.M.; Milan, D.J.; Snieder, H.; Samani, N.J.; Loos, R.J.

    2013-01-01

    Elevated resting heart rate is associated with greater risk of cardiovascular disease and mortality. In a 2-stage meta-analysis of genome-wide association studies in up to 181,171 individuals, we identified 14 new loci associated with heart rate and confirmed associations with all 7 previously

  19. FC-99 ameliorates sepsis-induced liver dysfunction by modulating monocyte/macrophage differentiation via Let-7a related monocytes apoptosis.

    Science.gov (United States)

    Zhao, Yarong; Zhu, Haiyan; Wang, Haining; Ding, Liang; Xu, Lizhi; Chen, Dai; Shen, Sunan; Hou, Yayi; Dou, Huan

    2018-03-13

    The liver is a vital target for sepsis-related injury, leading to inflammatory pathogenesis, multiple organ dysfunction and high mortality rates. Monocyte-derived macrophage transformations are key events in hepatic inflammation. N 1 -[(4-methoxy)methyl]-4-methyl-1,2-benzenediamine (FC-99) previously displayed therapeutic potential on experimental sepsis. However, the underlying mechanism of this protective effect is still not clear. FC-99 treatment attenuated the liver dysfunction in septic mice that was accompanied with reduced numbers of pro-inflammatory Ly6C hi monocytes in the peripheral blood and CD11b + F4/80 lo monocyte-derived macrophages in the liver. These effects were attributed to the FC-99-induced apoptosis of CD11b + cells. In PMA-differentiated THP-1 cells, FC-99 repressed the expression of CD11b, CD14 and caspase3 and resulted in a high proportion of Annexin V + cells. Moreover, let-7a-5p expression was abrogated upon CLP stimulation in vivo , whereas it was restored by FC-99 treatment. TargetScan analysis and luciferase assays indicated that the anti-apoptotic protein BCL-XL was targeted by let-7a-5p. BCL-XL was inhibited by FC-99 in order to induce monocyte apoptosis, leading to the impaired monocyte-to-macrophage differentiation. Murine acute liver failure was generated by caecal ligation puncture surgery after FC-99 administration; Blood samples and liver tissues were collected to determine the monocyte/macrophage subsets and the induction of apoptosis. Human acute monocytic leukemia cell line (THP-1) cells were pretreated with FC-99 followed by phorbol-12-myristate-13-acetate (PMA) stimulation, in order to induce monocyte-to-macrophage differentiation. The target of FC-99 and the mechanistic analyses were conducted by microarrays, qRT-PCR validation, TargetScan algorithms and a luciferase report assay. FC-99 exhibits potential therapeutic effects on CLP-induced liver dysfunction by restoring let-7a-5p levels.

  20. Relative influence of age, resting heart rate and sedentary life style in short-term analysis of heart rate variability

    Directory of Open Access Journals (Sweden)

    E.R. Migliaro

    2001-04-01

    Full Text Available In order to assess the relative influence of age, resting heart rate (HR and sedentary life style, heart rate variability (HRV was studied in two different groups. The young group (YG consisted of 9 sedentary subjects aged 15 to 20 years (YG-S and of 9 nonsedentary volunteers (YG-NS also aged 15 to 20. The elderly sedentary group (ESG consisted of 16 sedentary subjects aged 39 to 82 years. HRV was assessed using a short-term procedure (5 min. R-R variability was calculated in the time-domain by means of the root mean square successive differences. Frequency-domain HRV was evaluated by power spectrum analysis considering high frequency and low frequency bands. In the YG the effort tolerance was ranked in a bicycle stress test. HR was similar for both groups while ESG showed a reduced HRV compared with YG. Within each group, HRV displayed a negative correlation with HR. Although YG-NS had better effort tolerance than YG-S, their HR and HRV were not significantly different. We conclude that HRV is reduced with increasing HR or age, regardless of life style. The results obtained in our short-term study agree with others of longer duration by showing that age and HR are the main determinants of HRV. Our results do not support the idea that changes in HRV are related to regular physical activity.

  1. Relative influence of age, resting heart rate and sedentary life style in short-term analysis of heart rate variability.

    Science.gov (United States)

    Migliaro, E R; Contreras, P; Bech, S; Etxagibel, A; Castro, M; Ricca, R; Vicente, K

    2001-04-01

    In order to assess the relative influence of age, resting heart rate (HR) and sedentary life style, heart rate variability (HRV) was studied in two different groups. The young group (YG) consisted of 9 sedentary subjects aged 15 to 20 years (YG-S) and of 9 nonsedentary volunteers (YG-NS) also aged 15 to 20. The elderly sedentary group (ESG) consisted of 16 sedentary subjects aged 39 to 82 years. HRV was assessed using a short-term procedure (5 min). R-R variability was calculated in the time-domain by means of the root mean square successive differences. Frequency-domain HRV was evaluated by power spectrum analysis considering high frequency and low frequency bands. In the YG the effort tolerance was ranked in a bicycle stress test. HR was similar for both groups while ESG showed a reduced HRV compared with YG. Within each group, HRV displayed a negative correlation with HR. Although YG-NS had better effort tolerance than YG-S, their HR and HRV were not significantly different. We conclude that HRV is reduced with increasing HR or age, regardless of life style. The results obtained in our short-term study agree with others of longer duration by showing that age and HR are the main determinants of HRV. Our results do not support the idea that changes in HRV are related to regular physical activity.

  2. Multidetector-row computed tomography coronary angiography. Optimization of image reconstruction phase according to the heart rate

    International Nuclear Information System (INIS)

    Nagatani, Yukihiro; Takahashi, Masashi; Takazakura, Ryutaro; Nitta, Norihisa; Murata, Kiyoshi; Ushio, Noritoshi; Matsuo, Shinro; Yamamoto, Takashi; Horie, Minoru

    2007-01-01

    The purpose of this study was to optimize the image reconstruction phase of multidetector-row computed tomography (MDCT) coronary angiography according to the heart rate is crucial. Scan data were reconstructed for 10 different phases in 58 sequential patients who under went 8-row cardiac MDCT. The obtained images were scored and compared in terms of motion artifacts and visibility of the vessels, and moreover, electrocardiogram (ECG) record-based evaluations were added for clarification of the temporal relationships among these 10 phases. In the cases with lower heart rates ( 65 beats/mm), they were obtained in the late systolic period. As the heart rate increased, the optimal image reconstruction phase changed from mid diastole to late systole. However, it is recommended to try to decrease the heart rate of patients before data acquisition. (author)

  3. Facial electromyogram and heart-rate correlates of a paradoxical attitude change to antinuclear war information

    International Nuclear Information System (INIS)

    Vigne, J.J.; Dale, J.A.; Klions, H.L.

    1988-01-01

    The effects of film images versus film descriptions of the effects of nuclear explosions (versus a no-film control) on corrugator muscle tension, heart rate, attitude and mood were investigated. The last 5 min. of the images were associated with more corrugator tension for that condition when compared to the last 5 min. of the description condition. The groups did not differ in heart rate but women in both groups showed an increase in heart rate whereas men in both groups showed a decrease in heart rate. Film groups did not differ in their significant increases in anxiety, hostility, and depression on the Multiple Adjective Affect Checklist. On the pretest there was no significant correlation between scores on Betts' Questionnaire Upon Mental Imagery and scores on Goldenring and Doctor's index of concern for nuclear war. The vivid-image film group showed a decrease in concern for nuclear war when compared to the descriptive film group and the no-film control

  4. The antiarrhythmic effect of vagal stimulation after acute coronary occlusion: Role of the heart rate.

    Science.gov (United States)

    Manati, Waheed; Pineau, Julien; Doñate Puertas, Rosa; Morel, Elodie; Quadiri, Timour; Bui-Xuan, Bernard; Chevalier, Philippe

    2018-01-03

    Strong evidence suggests a causal link between autonomic disturbances and ventricular arrhythmias. However, the mechanisms underlying the antiarrhythmic effect of vagal stimulation are poorly understood. The vagal antiarrhythmic effect might be modulated by a decrease in heart rate. the proximal anterior interventricular artery was occluded in 16 pigs by clamping under general anaesthesia. Group 1: heart rates remained spontaneous (n = 6; 12 occlusions); Group 2: heart rates were fixed at 190 beats per minute (bpm) with atrial electrical stimulation (n = 10; 20 occlusions). Each pig received two occlusions, 30 min apart, one without and one with vagal stimulation (10 Hz, 2 ms, 5-20 mA). The antiarrhythmic effect of vagal activation was defined as the time to the appearance of ventricular fibrillation (VF) after occlusion. In Group 1, vagal stimulation triggered a significant decrease in basal heart rate (132 ± 4 vs. 110 ± 17 bpm, p coronary occlusion (1102 ± 85 vs. 925 ± 41 s, p acute coronary occlusion.

  5. State Anxiety and Nonlinear Dynamics of Heart Rate Variability in Students.

    Science.gov (United States)

    Dimitriev, Dimitriy A; Saperova, Elena V; Dimitriev, Aleksey D

    2016-01-01

    Clinical and experimental research studies have demonstrated that the emotional experience of anxiety impairs heart rate variability (HRV) in humans. The present study investigated whether changes in state anxiety (SA) can also modulate nonlinear dynamics of heart rate. A group of 96 students volunteered to participate in the study. For each student, two 5-minute recordings of beat intervals (RR) were performed: one during a rest period and one just before a university examination, which was assumed to be a real-life stressor. Nonlinear analysis of HRV was performed. The Spielberger's State-Trait Anxiety Inventory was used to assess the level of SA. Before adjusting for heart rate, a Wilcoxon matched pairs test showed significant decreases in Poincaré plot measures, entropy, largest Lyapunov exponent (LLE), and pointwise correlation dimension (PD2), and an increase in the short-term fractal-like scaling exponent of detrended fluctuation analysis (α1) during the exam session, compared with the rest period. A Pearson analysis indicated significant negative correlations between the dynamics of SA and Poincaré plot axes ratio (SD1/SD2), and between changes in SA and changes in entropy measures. A strong negative correlation was found between the dynamics of SA and LLE. A significant positive correlation was found between the dynamics of SA and α1. The decreases in Poincaré plot measures (SD1, complex correlation measure), entropy measures, and LLE were still significant after adjusting for heart rate. Corrected α1 was increased during the exam session. As before, the dynamics of adjusted LLE was significantly correlated with the dynamics of SA. The qualitative increase in SA during academic examination was related to the decrease in the complexity and size of the Poincaré plot through a reduction of both the interbeat interval and its variation.

  6. State Anxiety and Nonlinear Dynamics of Heart Rate Variability in Students.

    Directory of Open Access Journals (Sweden)

    Dimitriy A Dimitriev

    Full Text Available Clinical and experimental research studies have demonstrated that the emotional experience of anxiety impairs heart rate variability (HRV in humans. The present study investigated whether changes in state anxiety (SA can also modulate nonlinear dynamics of heart rate.A group of 96 students volunteered to participate in the study. For each student, two 5-minute recordings of beat intervals (RR were performed: one during a rest period and one just before a university examination, which was assumed to be a real-life stressor. Nonlinear analysis of HRV was performed. The Spielberger's State-Trait Anxiety Inventory was used to assess the level of SA.Before adjusting for heart rate, a Wilcoxon matched pairs test showed significant decreases in Poincaré plot measures, entropy, largest Lyapunov exponent (LLE, and pointwise correlation dimension (PD2, and an increase in the short-term fractal-like scaling exponent of detrended fluctuation analysis (α1 during the exam session, compared with the rest period. A Pearson analysis indicated significant negative correlations between the dynamics of SA and Poincaré plot axes ratio (SD1/SD2, and between changes in SA and changes in entropy measures. A strong negative correlation was found between the dynamics of SA and LLE. A significant positive correlation was found between the dynamics of SA and α1. The decreases in Poincaré plot measures (SD1, complex correlation measure, entropy measures, and LLE were still significant after adjusting for heart rate. Corrected α1 was increased during the exam session. As before, the dynamics of adjusted LLE was significantly correlated with the dynamics of SA.The qualitative increase in SA during academic examination was related to the decrease in the complexity and size of the Poincaré plot through a reduction of both the interbeat interval and its variation.

  7. Natural form of noncytolytic flexible human Fc as a long-acting carrier of agonistic ligand, erythropoietin.

    Directory of Open Access Journals (Sweden)

    Se Jin Im

    Full Text Available Human IgG1 Fc has been widely used as a bioconjugate, but exhibits shortcomings, such as antibody- and complement-mediated cytotoxicity as well as decreased bioactivity, when applied to agonistic proteins. Here, we constructed a nonimmunogenic, noncytolytic and flexible hybrid Fc (hyFc consisting of IgD and IgG4, and tested its function using erythropoietin (EPO conjugate, EPO-hyFc. Despite low amino acid homology (20.5% between IgD Fc and IgG4 Fc, EPO-hyFc retained "Y-shaped" structure and repeated intravenous administrations of EPO-hyFc into monkeys did not generate EPO-hyFc-specific antibody responses. Furthermore, EPO-hyFc could not bind to FcγR I and C1q in contrast to EPO-IgG1 Fc. In addition, EPO-hyFc exhibited better in vitro bioactivity and in vivo bioactivity in rats than EPO-IgG1 Fc, presumably due to the high flexibility of IgD. Moreover, the mean serum half-life of EPO-hyFc(H, a high sialic acid content form of EPO-hyFc, was approximately 2-fold longer than that of the heavily glycosylated EPO, darbepoetin alfa, in rats. More importantly, subcutaneous injection of EPO-hyFc(H not only induced a significantly greater elevation of serum hemoglobin levels than darbepoetin alfa in both normal rats and cisplatin-induced anemic rats, but also displayed a delayed time to maximal serum level and twice final area-under-the-curve (AUC(last. Taken together, hyFc might be a more attractive Fc conjugate for agonistic proteins/peptides than IgG1 Fc due to its capability to elongate their half-lives without inducing host effector functions and hindering bioactivity of fused molecules. Additionally, a head-to-head comparison demonstrated that hyFc-fusion strategy more effectively improved the in vivo bioactivity of EPO than the hyperglycosylation approach.

  8. Natural form of noncytolytic flexible human Fc as a long-acting carrier of agonistic ligand, erythropoietin.

    Science.gov (United States)

    Im, Se Jin; Yang, Sang In; Yang, Se Hwan; Choi, Dong Hoon; Choi, So Young; Kim, Hea Sook; Jang, Do Soo; Jin, Kyeong Sik; Chung, Yo-Kyung; Kim, Seung-Hee; Paik, Sang Hoon; Park, Yoo Chang; Chung, Moon Koo; Kim, Yong Bum; Han, Kang-Hyun; Choi, Kwan Yong; Sung, Young Chul

    2011-01-01

    Human IgG1 Fc has been widely used as a bioconjugate, but exhibits shortcomings, such as antibody- and complement-mediated cytotoxicity as well as decreased bioactivity, when applied to agonistic proteins. Here, we constructed a nonimmunogenic, noncytolytic and flexible hybrid Fc (hyFc) consisting of IgD and IgG4, and tested its function using erythropoietin (EPO) conjugate, EPO-hyFc. Despite low amino acid homology (20.5%) between IgD Fc and IgG4 Fc, EPO-hyFc retained "Y-shaped" structure and repeated intravenous administrations of EPO-hyFc into monkeys did not generate EPO-hyFc-specific antibody responses. Furthermore, EPO-hyFc could not bind to FcγR I and C1q in contrast to EPO-IgG1 Fc. In addition, EPO-hyFc exhibited better in vitro bioactivity and in vivo bioactivity in rats than EPO-IgG1 Fc, presumably due to the high flexibility of IgD. Moreover, the mean serum half-life of EPO-hyFc(H), a high sialic acid content form of EPO-hyFc, was approximately 2-fold longer than that of the heavily glycosylated EPO, darbepoetin alfa, in rats. More importantly, subcutaneous injection of EPO-hyFc(H) not only induced a significantly greater elevation of serum hemoglobin levels than darbepoetin alfa in both normal rats and cisplatin-induced anemic rats, but also displayed a delayed time to maximal serum level and twice final area-under-the-curve (AUC(last)). Taken together, hyFc might be a more attractive Fc conjugate for agonistic proteins/peptides than IgG1 Fc due to its capability to elongate their half-lives without inducing host effector functions and hindering bioactivity of fused molecules. Additionally, a head-to-head comparison demonstrated that hyFc-fusion strategy more effectively improved the in vivo bioactivity of EPO than the hyperglycosylation approach.

  9. The fall in the rate of death from heart diseases

    International Nuclear Information System (INIS)

    Bemski, G.

    1983-01-01

    A self limiting interaction between heart disease producing factors and genetic factors is postulated. Such an interaction could be responsable for the fall in rate of death from ischemic disease observed in the United States. (Author) [pt

  10. [Heart rate variability and physical exercise. Current status].

    Science.gov (United States)

    Hottenrott, Kuno; Hoos, Olaf; Esperer, Hans Dieter

    2006-09-01

    Heart rate variability (HRV) has long been used in risk stratification for sudden cardiac death and diabetic autonomic neuropathy. In recent years, both time and frequency domain indices of HRV also gained increasing interest in sports and training sciences. In these fields, HRV is currently used for the noninvasive assessment of autonomic changes associated with short-term and long-term endurance exercise training in both leisure sports activity and high-performance training. Furthermore, HRV is being investigated as a diagnostic marker of overreaching and overtraining.A large body of evidence shows that, in healthy subjects and cardiovascular patients of all ages (up to an age of 70 years), regular aerobic training usually results in a significant improvement of overall as well as instantaneous HRV. These changes, which are accompanied by significant reductions in heart rates both at rest and during submaximal exercise, reflect an increase in autonomic efferent activity and a shift in favor of enhanced vagal modulation of the cardiac rhythm. Regular aerobic training of moderate volume and intensity over a minimum period of 3 months seems to be necessary to ensure these effects, which might be associated with a prognostic benefit regarding overall mortality.At present, available data does not allow for final conclusions with respect to the usefulness of traditional HRV indices in assessing an individual's exercise performance and monitoring training load. The discrepant results published so far are due to several factors including insufficient study size and design, and different HRV methods. Large-sized and prospectively designed studies are necessary for clarification. It also remains to be seen, whether the traditional HRV indices prove useful in the diagnosis of overreaching and overtraining. Preliminary results, though promising, need to be confirmed in larger cohorts.A basic problem in HRV analysis is nonstationarity of the heart rate signal, which holds

  11. Higher Precision of Heart Rate Compared with VO2 to Predict Exercise Intensity in Endurance-Trained Runners.

    Science.gov (United States)

    Reis, Victor M; den Tillaar, Roland Van; Marques, Mario C

    2011-01-01

    The aim of the present study was to assess the precision of oxygen uptake with heart rate regression during track running in highly-trained runners. Twelve national and international level male long-distance road runners (age 30.7 ± 5.5 yrs, height 1.71 ± 0.04 m and mass 61.2 ± 5.8 kg) with a personal best on the half marathon of 62 min 37 s ± 1 min 22 s participated in the study. Each participant performed, in an all-weather synthetic track five, six min bouts at constant velocity with each bout at an increased running velocity. The starting velocity was 3.33 m·s(-1) with a 0.56 m·s(-1) increase on each subsequent bout. VO2 and heart rate were measured during the runs and blood lactate was assessed immediately after each run. Mean peak VO2 and mean peak heart rate were, respectively, 76.2 ± 9.7 mL·kg(-1)·min(-1) and 181 ± 13 beats·min(-1). The linearity of the regressions between heart rate, running velocity and VO2 were all very high (r > 0.99) with small standard errors of regression (i.e. Sy.x at the velocity associated with the 2 and 4 mmol·L(-1) lactate thresholds). The strong relationships between heart rate, running velocity and VO2 found in this study show that, in highly trained runners, it is possible to have heart rate as an accurate indicator of energy demand and of the running speed. Therefore, in this subject cohort it may be unnecessary to use VO2 to track changes in the subjects' running economy during training periods. Key pointsHeart rate is used in the control of exercise intensity in endurance sports.However, few studies have quantified the precision of its relationship with oxygen uptake in highly trained runners.We evaluated twelve elite half-marathon runners during track running at various intensities and established three regressions: oxygen uptake / heart rate; heart rate / running velocity and oxygen uptake / running velocity.The three regressions presented, respectively, imprecision of 4,2%, 2,75% and 4,5% at the velocity

  12. Heart Rate Variability and Drawing Impairment in Hypoxemic COPD

    Science.gov (United States)

    Incalzi, Raffaele Antonelli; Corsonello, Andrea; Trojano, Luigi; Pedone, Claudio; Acanfora, Domenico; Spada, Aldo; D'Addio, Gianni; Maestri, Roberto; Rengo, Franco; Rengo, Giuseppe

    2009-01-01

    We studied 54 patients with hypoxemic chronic obstructive pulmonary disease (COPD). The Mini Mental State Examination and the Mental Deterioration Battery were used for neuropsychological assessment. Heart rate variability (HRV) was assessed based on 24-h Holter ECG recording. Mann-Whitney test was used to compare HRV parameters of patients…

  13. Variation in heart rate during submaximal exercise: Implications for monitoring training : Implications for monitoring training

    NARCIS (Netherlands)

    Lamberts, R.P.; Lemmink, K.A.P.M.; Durandt, J.J.; Lambert, M.I.

    2004-01-01

    A change in heart rate at a controlled submaximal exercise intensity is used as a marker of training status. However, the standard error of measurement has not been studied systematically, and therefore a change in heart rate, which can be considered relevant, has not been determined. Forty-four

  14. Ventricular fibrillation occurring after atrioventricular node ablation despite minimal difference between pre- and post-ablation heart rates.

    Science.gov (United States)

    Squara, F; Theodore, G; Scarlatti, D; Ferrari, E

    2017-02-01

    We report the case of an 82-year-old man presenting with ventricular fibrillation (VF) occurring acutely after atrioventricular node (AVN) ablation. This patient had severe valvular cardiomyopathy, chronic atrial fibrillation (AF), and underwent prior to the AVN ablation a biventricular implantable cardiac defibrillator positioning. The VF was successfully cardioverted with one external electrical shock. What makes this presentation original is that the pre-ablation spontaneous heart rate in AF was slow (84 bpm), and that VF occurred after ablation despite a minimal heart rate drop of only 14 bpm. VF is the most feared complication of AVN ablation, but it had previously only been described in case of acute heart rate drop after ablation of at least 30 bpm (and more frequently>50 bpm). This case report highlights the fact that VF may occur after AVN ablation regardless of the heart rate drop, rendering temporary fast ventricular pacing mandatory whatever the pre-ablation heart rate. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  15. Heart rate and time-motion analyses in top junior players during basketball matches

    Directory of Open Access Journals (Sweden)

    Karel Hůlka

    2013-09-01

    Full Text Available BACKGROUND: Basketball performance can be classified as an intermittent physical activity due to the changing situational game conditions and the number of intervening variables. It is necessary to have detailed knowledge about the performance of basketball players during a match as a background for more specific planning of the training process. OBJECTIVE: The aim of this study was to analyse the indicators of internal and external load of basketball player’s performance during a match of U18 top men basketball players as a background for the planning of specific training processes. METHODS: Thirty-two Czech top junior basketball players (male, aged 16.88 ± 0.72 years participated in this research. The heart rate was recorded and time-motion analysis was conducted during six warm-up matches. RESULTS: The average heart rate was measured to be 167.47 ± 13.01 beats • min.–1, which corresponded to 85.06 ± 6.40% of peak heart rate. The percentages of the total time spent over and under 85% were 63.12% and 36.88%, respectively. Average distance covered was measured to be 5,880.91 ± 831.01 meters. The average work : rest ratio was 1 : 7.95 ± 1.83, ranging from 1 : 4.80 to 1 : 10.92. CONCLUSIONS: The results from these matches suggest that the exercise intensity and sprint activity observed during junior basketball are dependent on the player's position and partly on the level of the performance. The heart rate during a match was not dependent on the positions, however, time-motion analysis revealed significant differences between three basketball positions during a match. The combination of heart rate and time-motion analysis is recommended.

  16. Fc receptor gamma subunit polymorphisms and systemic lupus erythematosus

    International Nuclear Information System (INIS)

    Al-Ansari, Aliya; Ollier, W.E.; Gonzalez-Gay, Miguel A.; Gul, Ahmet; Inanac, Murat; Ordi, Jose; Teh, Lee-Suan; Hajeer, Ali H.

    2004-01-01

    To investigate the possible association between Fc receptor gamma polymorphisms and systemic lupus erythematosus (SLE). We have investigated the full FcR gamma gene for polymorphisms using polymerase chain reaction (PCR)-single strand confirmational polymorphisms and DNA sequencing .The polymorphisms identified were genotype using PCR-restriction fragment length polymorphism. Systemic lupus erythematosus cases and controls were available from 3 ethnic groups: Turkish, Spanish and Caucasian. The study was conducted in the year 2001 at the Arthritis Research Campaign, Epidemiology Unit, Manchester University Medical School, Manchester, United Kingdom. Five single nucleotide polymorphisms were identified, 2 in the promoter, one in intron 4 and, 2 in the 3'UTR. Four of the 5 single nucleotide polymorphisms (SNPs) were relatively common and investigated in the 3 populations. Allele and genotype frequencies of all 4 investigated SNPs were not statistically different cases and controls. fc receptor gamma gene does not appear to contribute to SLE susceptibility. The identified polymorphisms may be useful in investigating other diseases where receptors containing the FcR gamma subunit contribute to the pathology. (author)

  17. Atenolol Is Associated with Lower Day of Surgery Heart Rate as compared to Long and Short-acting Metoprolol

    Science.gov (United States)

    Schonberger, Robert B.; Brandt, Cynthia; Feinleib, Jessica; Dai, Feng; Burg, Matthew M.

    2012-01-01

    Objectives We analyzed the association between outpatient beta-blocker type and day-of-surgery heart rate in ambulatory surgical patients. We further investigated whether differences in day of surgery heart rate between atenolol and metoprolol could be explained by once-daily versus twice-daily dosing regimens. Design Retrospective observational study. Setting VA Hospital Participants Ambulatory surgical patients on chronic atenolol or metoprolol. Interventions None. Measurements and Main Results Using a propensity-score matched cohort, we compared day of surgery heart rates of patients prescribed atenolol versus metoprolol. We then differentiated between once-daily and twice-daily metoprolol formulations and compared day of surgery heart rates within a general linear model. Day of surgery heart rates in patients prescribed atenolol vs. any metoprolol formulation were slower by a mean of 5.1 beats/min (66.6 vs. 71.7; 95% CI of difference 1.9 to 8.3, p=0.002), a difference that was not observed in preoperative primary care visits. The general linear model demonstrated that patients prescribed atenolol (typically QD dosing) had a mean day of surgery heart rate 5.6 beats/min lower compared to patients prescribed once-daily metoprolol succinate (68.9 vs. 74.5; 95% CI of difference: −8.6 to −2.6, p<0.001) and 3.8 beats/minute lower compared to patients prescribed twice-daily metoprolol tartrate (68.9 vs. 72.7; 95% CI of difference: −6.1 to −1.6, p<0.001). Day of surgery heart rates were similar between different formulations of metoprolol (95% CI of difference: −1.0 to +4.6, p=0.22). Conclusions Atenolol is associated with lower day of surgery heart rate vs. metoprolol. The heart rate difference is specific to the day of surgery and is not explained by once-daily versus twice-daily dosing regimens. PMID:22889605

  18. Longitudinal Associations of Leptin and Adiponectin with Heart Rate Variability in Children

    Directory of Open Access Journals (Sweden)

    Roos Van De Wielle

    2017-07-01

    Full Text Available For early prevention of cardiovascular disease, early detection and risk factor insights are necessary. The autonomic balance reflects cardiovascular risk and can be measured by heart rate variability (HRV. Therefore, our purpose is to examine associations between HRV and the energy-related biomarkers leptin and adiponectin in children. Participants of this study were Belgian children recruited for the longitudinal ChiBS study (year 2010–2012. HRV was measured and fasting blood samples were taken in 249 children at baseline (4.4–11.0 y and 223 children at follow-up (6.7–12.2 y. Cross-sectional and longitudinal linear regression analyses were separated by sex and adjusted for age, socio-economic status, body fat%, negative emotions, puberty, and mean heart rate. Leptin was a negative cross-sectional and longitudinal predictor of parasympathetic activity in boys; while leptin in girls was cross-sectionally associated with higher LF and LF/HF suggesting sympathetic predominance. Adiponectin was a negative cross-sectional and longitudinal predictor of parasympathetic activity in boys; but when adjusting for mean heart rate, this effect disappeared and adiponectin was a positive cross-sectional and longitudinal predictor of parasympathetic activity in girls. These results stress the importance of considering sex differences and adjustment for heart rate in testing HRV predictors. Leptin seemed disadvantageous for the autonomic balance, while adiponectin seemed advantageous for the autonomic balance in girls only. More research is needed to see whether leptin and adiponectin are interesting in cardiovascular screening/prevention or in determining the cardiovascular gain during weight loss follow-up.

  19. Musical Auditory Stimulation Influences Heart Rate Autonomic Responses to Endodontic Treatment

    Directory of Open Access Journals (Sweden)

    Milana Drumond Ramos Santana

    2017-01-01

    Full Text Available We aimed to evaluate the acute effect of musical auditory stimulation on heart rate autonomic regulation during endodontic treatment. The study included 50 subjects from either gender between 18 and 40 years old, diagnosed with irreversible pulpitis or pulp necrosis of the upper front teeth and endodontic treatment indication. HRV was recorded 10 minutes before (T1, during (T2, and immediately (T3 and T4 after endodontic treatment. The volunteers were randomly divided into two equal groups: exposed to music (during T2, T3, and T4 or not. We found no difference regarding salivary cortisol and anxiety score. In the group with musical stimulation heart rate decreased in T3 compared to T1 and mean RR interval increased in T2 and T3 compared to T1. SDNN and TINN indices decreased in T3 compared to T4, the RMSSD and SD1 increased in T4 compared to T1, the SD2 increased compared to T3, and LF (low frequency band increased in T4 compared to T1 and T3. In the control group, only RMSSD and SD1 increased in T3 compared to T1. Musical auditory stimulation enhanced heart rate autonomic modulation during endodontic treatment.

  20. The heart rate response to nintendo wii boxing in young adults.

    Science.gov (United States)

    Bosch, Pamela R; Poloni, Joseph; Thornton, Andrew; Lynskey, James V

    2012-06-01

    To determine if 30 minutes of Nintendo Wii Sports boxing provides cardiorespiratory benefits and contributes to the daily exercise recommendations for healthy young adults. Twenty healthy 23- to 27-year-olds participated in two sessions to measure maximum heart rate (HR(max)) via a treadmill test and heart rate (HR) response to 30 minutes of Wii Sports boxing. Heart rate in beats per minute (bpm) was measured continuously, and exercise intensity during each minute of play was stratified as a percentage of HR(max). Mixed designs analysis of variance (ANOVA) and Pearson product moment correlations were used to analyze the data. Mean (SD) HR response to boxing was 143 (15) bpm or 77.5% (10.0%) of HR(max). The mean HR response for experienced participants was significantly lower than inexperienced participants, P = .007. The ANOVA revealed a significant interaction between experience and time spent at various intensities, P = .009. Experienced participants spent more time in light to vigorous intensities, inexperienced participants in moderate to very hard intensities. Fitness was not correlated with mean HR response to boxing, P = .49. Thirty minutes of Nintendo Wii Sports boxing provides a moderate to vigorous aerobic response in healthy young adults and can contribute to daily recommendations for physical activity.

  1. Association between resting heart rate and N-terminal pro-brain natriuretic peptide in a community-based population study in Beijing

    Directory of Open Access Journals (Sweden)

    Cao R

    2014-12-01

    Full Text Available Ruihua Cao, Yongyi Bai, Ruyi Xu, Ping Ye Department of Geriatric Cardiology, Chinese PLA General Hospital, Beijing, People’s Republic of China Background: N-terminal pro-brain natriuretic peptide (NT-proBNP is associated with an increased risk of cardiac insufficiency, which possibly leads to heart failure. However, the relationship between resting heart rate and NT-proBNP is unclear.Objective: This study focuses on this relativity between resting heart rate and plasma NT-proBNP levels in a surveyed community-based population.Methods: We evaluated the relativity between resting heart rate and plasma levels of NT-proBNP in 1,567 participants (mean age 61.0 years, range 21–96 years from a community-based population in Beijing, People’s Republic of China.Results: In patients with high resting heart rate (≥75 beats/min, NT-proBNP was higher than in those having low resting heart rate (<75 beats/min. In multiple linear stepwise regression analysis, plasma NT-proBNP was associated with resting heart rate (partial correlation coefficient, 0.82; 95% confidence interval, 0.18–1.51; P=0.011. A subsequent subgroup analysis revealed that the association between resting heart rate and plasma NT-proBNP was strengthened in subjects over 60 years old (partial correlation coefficient 1.28; 95% confidence interval, 0.49–2.36; P=0.031; while the relativity between resting heart rate and plasma NT-proBNP was not emerged in the younger subgroup (<60 years old.Conclusions: Resting heart rate was associated with plasma NT-proBNP in the elderly, which indicated a relationship between resting heart rate and cardiac function damage. Keywords: resting heart rate, N-terminal pro-brain natriuretic peptide, epidemiology, cardiac function, relationship

  2. Effects of Orthostatism and Hemodialysis on Mean Heart Period and Fractal Heart Rate Properties of Chronic Renal Failure Patients.

    Science.gov (United States)

    Echeverría, Juan C; Infante, Oscar; Pérez-Grovas, Héctor; González, Hortensia; José, Marco V; Lerma, Claudia

    2017-11-01

    The aim of this work was to evaluate the short-term fractal index (α 1 ) of heart rate variability (HRV) in chronic renal failure (CRF) patients by identifying the effects of orthostatism and hemodialysis (HD), and by evaluating the correlation between α 1 and the mean RR interval from sinus beats (meanNN). HRV time series were derived from ECG data of 19 CRF patients and 20 age-matched healthy subjects obtained at supine and orthostatic positions (lasting 5 min each). Data from CRF patients were collected before and after HD. α 1 was calculated from each time series and compared by analysis of variance. Pearson's correlations between meanNN and α 1 were calculated using the data from both positions by considering three groups: healthy subjects, CRF before HD and CRF after HD. At supine position, α 1 of CRF patients after HD (1.17 ± 0.30) was larger (P renal disease condition in itself. In conclusion, as in healthy subjects, α 1 of CRF patients correlates with meanNN after HD (indicating a more irregular-like HRV behavior at slower heart rates). This suggests that CRF patients with stable blood pressure preserve a regulatory adaptability despite a shifted setting point of the heart period (i.e., higher heart rate) in comparison with healthy subjects. © 2017 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  3. Rapid polyclonal desensitization with antibodies to IgE and FcεRIα.

    Science.gov (United States)

    Khodoun, Marat V; Kucuk, Zeynep Yesim; Strait, Richard T; Krishnamurthy, Durga; Janek, Kevin; Lewkowich, Ian; Morris, Suzanne C; Finkelman, Fred D

    2013-06-01

    Rapid desensitization, a procedure in which persons allergic to an antigen are treated at short intervals with increasing doses of that antigen until they tolerate a large dose, is an effective, but risky, way to induce temporary tolerance. We wanted to determine whether this approach can be adapted to suppress all IgE-mediated allergies in mice by injecting serially increasing doses of monoclonal antibodies (mAbs) to IgE or FcεRIα. Active and passive models of antigen- and anti-IgE mAb-induced IgE-mediated anaphylaxis were used. Mice were desensitized with serially increasing doses of anti-IgE mAb, anti-FcεRIα mAb, or antigen. Development of shock (hypothermia), histamine and mast cell protease release, cytokine secretion, calcium flux, and changes in cell number and FcεRI and IgE expression were evaluated. Rapid desensitization with anti-IgE mAb suppressed IgE-mediated immediate hypersensitivity; however, some mice developed mild anaphylaxis during desensitization. Rapid desensitization with anti-FcεRIα mAb that only binds FcεRI that is not occupied by IgE suppressed both active and passive IgE-mediated anaphylaxis without inducing disease. It quickly, but temporarily, suppressed IgE-mediated anaphylaxis by decreasing mast cell signaling through FcεRI, then slowly induced longer lasting mast cell unresponsiveness by removing membrane FcεRI. Rapid desensitization with anti-FcεRIα mAb was safer and longer lasting than rapid desensitization with antigen. A rapid desensitization approach with anti-FcεRIα mAb safely desensitizes mice to IgE-mediated anaphylaxis by inducing mast cell anergy and later removing all mast cell IgE. Rapid desensitization with an anti-human FcεRIα mAb may be able to prevent human IgE-mediated anaphylaxis. Copyright © 2013 American Academy of Allergy, Asthma & Immunology. Published by Mosby, Inc. All rights reserved.

  4. Job strain and resting heart rate: a cross-sectional study in a Swedish random working sample

    Directory of Open Access Journals (Sweden)

    Peter Eriksson

    2016-03-01

    Full Text Available Abstract Background Numerous studies have reported an association between stressing work conditions and cardiovascular disease. However, more evidence is needed, and the etiological mechanisms are unknown. Elevated resting heart rate has emerged as a possible risk factor for cardiovascular disease, but little is known about the relation to work-related stress. This study therefore investigated the association between job strain, job control, and job demands and resting heart rate. Methods We conducted a cross-sectional survey of randomly selected men and women in Västra Götalandsregionen, Sweden (West county of Sweden (n = 1552. Information about job strain, job demands, job control, heart rate and covariates was collected during the period 2001–2004 as part of the INTERGENE/ADONIX research project. Six different linear regression models were used with adjustments for gender, age, BMI, smoking, education, and physical activity in the fully adjusted model. Job strain was operationalized as the log-transformed ratio of job demands over job control in the statistical analyses. Results No associations were seen between resting heart rate and job demands. Job strain was associated with elevated resting heart rate in the unadjusted model (linear regression coefficient 1.26, 95 % CI 0.14 to 2.38, but not in any of the extended models. Low job control was associated with elevated resting heart rate after adjustments for gender, age, BMI, and smoking (linear regression coefficient −0.18, 95 % CI −0.30 to −0.02. However, there were no significant associations in the fully adjusted model. Conclusions Low job control and job strain, but not job demands, were associated with elevated resting heart rate. However, the observed associations were modest and may be explained by confounding effects.

  5. The relationship between the parameters (Heart rate, Ejection fraction and BMI) and the maximum enhancement time of ascending aorta

    International Nuclear Information System (INIS)

    Jang, Young Ill; June, Woon Kwan; Dong, Kyeong Rae

    2007-01-01

    In this study, Bolus Tracking method was used to investigate the parameters affecting the time when contrast media is reached at 100 HU (T 100 ) and studied the relationship between parameters and T 100 because the time which is reached at aorta through antecubital vein after injecting contrast media is different from person to person. Using 64 MDCT, Cadiac CT, the data were obtained from 100 patients (male: 50, female: 50, age distribution: 21⁓81, average age: 57.5) during July and September, 2007 by injecting the contrast media at 4 ml∙sec -1 through their antecubital vein except having difficulties in stopping their breath and having arrhythmia. Using Somatom Sensation Cardiac 64 Siemens, patients’ height and weight were measured to know their mean Heart rate and BMI. Ejection Fraction was measured using Argus Program at Wizard Workstation. Variances of each parameter were analyzed depending on T 100 ’s variation with multiple comparison and the correlation of Heart rate, Ejection Fraction and BMI were analyzed, as well. According to T 100 ’s variation caused by Heart rate, Ejection Fraction and BMI variations, the higher patients’ Heart Rate and Ejection Fraction were, the faster T 100 ’s variations caused by Heart Rate and Ejection Fraction were. The lower their Heart Rate and Ejection Fraction were, the slower T 100 ’s variations were, but T 100 ’s variations caused by BMI were not affected. In the correlation between T 100 and parameters, Heart Rate (p⁄0.01) and Ejection Fraction (p⁄0.05) were significant, but BMI was not significant (p¤0.05). In the Heart Rate, Ejection Fraction and BMI depending on Fast (17 sec and less), Medium (18⁓21 sec), Slow (22 sec and over) Heart Rate was significant at Fast and Slow and Ejection Fraction was significant Fast and Slow as well as Medium and Slow (p⁄0.05), but BMI was not statistically significant. Of the parameters (Heart Rate, Ejection Fraction and BMI) which would affect T 100 , Heart

  6. Effects of omega-3 fatty acids on resting heart rate, heart rate recovery after exercise, and heart rate variability in men with healed myocardial infarctions and depressed ejection fractions.

    Science.gov (United States)

    O'Keefe, James H; Abuissa, Hussam; Sastre, Antonio; Steinhaus, David M; Harris, William S

    2006-04-15

    We explored possible mechanisms by which recommended intakes of omega-3 fatty acids may decrease the risk for sudden cardiac death in patients with documented coronary heart disease. The cardioprotective effects of omega-3 fatty acids have been documented in epidemiologic and randomized controlled trials. These fatty acids are presumed to decrease susceptibility to fatal arrhythmias, but whether this is mediated by classic risk factors or direct cardiac mechanisms is not known. Eighteen white men with a history of myocardial infarction and ejection fractions <40% were randomized to placebo or omega-3 fatty acids (585 mg of docosahexaenoic acid and 225 mg of eicosapentaenoic acid) for two 4-month periods in a crossover design. At the end of each period, heart rate (HR), HR variability, and rate of HR recovery after exercise were determined, as were effects on arterial compliance, blood pressure, cardiac function, and fasting serum levels of lipids and inflammatory markers. Omega-3 fatty acids decreased HR at rest from 73 +/- 13 to 68 +/- 13 beats/min (p <0.0001) and improved 1-minute HR recovery after exercise (-27 +/- 10 to -32 +/- 12 beats/min, p <0.01). HR variability in the high-frequency band increased (p <0.02), but no change was noted in overall HR variability. There were no significant effects on blood pressure, arterial compliance, lipids, or inflammatory markers. These changes are consistent with an increase in vagal activity and may in part explain the observed decrease in risk for sudden cardiac death seen with omega-3 fatty acid supplementation.

  7. Changes in heart rate variability and QT variability during the first trimester of pregnancy.

    Science.gov (United States)

    Carpenter, R E; D'Silva, L A; Emery, S J; Uzun, O; Rassi, D; Lewis, M J

    2015-03-01

    The risk of new-onset arrhythmia during pregnancy is high, presumably relating to changes in both haemodynamic and cardiac autonomic function. The ability to non-invasively assess an individual's risk of developing arrhythmia during pregnancy would therefore be clinically significant. We aimed to quantify electrocardiographic temporal characteristics during the first trimester of pregnancy and to compare these with non-pregnant controls. Ninety-nine pregnant women and sixty-three non-pregnant women underwent non-invasive cardiovascular and haemodynamic assessment during a protocol consisting of various physiological states (postural manoeurvres, light exercise and metronomic breathing). Variables measured included stroke volume, cardiac output, heart rate, heart rate variability, QT and QT variability and QTVI (a measure of the variability of QT relative to that of RR). Heart rate (p pregnancy only during the supine position (p pregnancy in all physiological states (p pregnancy in all states (p pregnancy is associated with substantial changes in heart rate variability, reflecting a reduction in parasympathetic tone and an increase in sympathetic activity. QTVI shifted to a less favourable value, reflecting a greater than normal amount of QT variability. QTVI appears to be a useful method for quantifying changes in QT variability relative to RR (or heart rate) variability, being sensitive not only to physiological state but also to gestational age. We support the use of non-invasive markers of cardiac electrical variability to evaluate the risk of arrhythmic events in pregnancy, and we recommend the use of multiple physiological states during the assessment protocol.

  8. Non-contact Real-time heart rate measurements based on high speed circuit technology research

    Science.gov (United States)

    Wu, Jizhe; Liu, Xiaohua; Kong, Lingqin; Shi, Cong; Liu, Ming; Hui, Mei; Dong, Liquan; Zhao, Yuejin

    2015-08-01

    In recent years, morbidity and mortality of the cardiovascular or cerebrovascular disease, which threaten human health greatly, increased year by year. Heart rate is an important index of these diseases. To address this status, the paper puts forward a kind of simple structure, easy operation, suitable for large populations of daily monitoring non-contact heart rate measurement. In the method we use imaging equipment video sensitive areas. The changes of light intensity reflected through the image grayscale average. The light change is caused by changes in blood volume. We video the people face which include the sensitive areas (ROI), and use high-speed processing circuit to save the video as AVI format into memory. After processing the whole video of a period of time, we draw curve of each color channel with frame number as horizontal axis. Then get heart rate from the curve. We use independent component analysis (ICA) to restrain noise of sports interference, realized the accurate extraction of heart rate signal under the motion state. We design an algorithm, based on high-speed processing circuit, for face recognition and tracking to automatically get face region. We do grayscale average processing to the recognized image, get RGB three grayscale curves, and extract a clearer pulse wave curves through independent component analysis, and then we get the heart rate under the motion state. At last, by means of compare our system with Fingertip Pulse Oximeter, result show the system can realize a more accurate measurement, the error is less than 3 pats per minute.

  9. Effects of Interval Training Programme on Resting Heart Rate in ...

    African Journals Online (AJOL)

    DATONYE ALASIA

    Subjects with Hypertension: A Randomized Controlled Trial. Type of Article: Original ... Resting Heart Rate in Subjects with Hypertension — Lamina S. et al investigate the effect of interval .... changes in VO max) of interest. In the t-test. 2.

  10. Modest weight loss in moderately overweight postmenopausal women improves heart rate variability

    DEFF Research Database (Denmark)

    Mouridsen, Mette Rauhe; Bendsen, Nathalie Tommerup; Astrup, Arne

    2013-01-01

    Purpose: To evaluate the effects of weight loss on heart rate (HR) and heart rate variability (HRV) parameters in overweight postmenopausal women. Design and Methods: Forty-nine overweight postmenopausal women with an average body mass index of 28.8 1.9 kg/m2 underwent a 12-week dietary weight......-to-normal intervals for each 5-min period (SDNNindex). Baseline body fat mass (FM%) and changes in body composition was determined by dual X-ray absorptiometry. Before and after the weight-loss period, total abdominal fat, intra-abdominal fat (IAAT), and subcutaneous abdominal fat (SCAT) were measured by single...

  11. Decreased heart rate variability in surgeons during night shifts

    DEFF Research Database (Denmark)

    Amirian, Ilda; Toftegård Andersen, Lærke; Rosenberg, Jacob

    2014-01-01

    BACKGROUND: Heart rate variability (HRV) has been used as a measure of stress and mental strain in surgeons. Low HRV has been associated with death and increased risk of cardiac events in the general population. The aim of this study was to clarify the effect of a 17-hour night shift on surgeons'...

  12. Anti-Hyperlipidaemic and Heart Rate Lowering Effects of Aqueous ...

    African Journals Online (AJOL)

    The anti-hyperlipidaemic and heart rate lowering potential of aqueous leaf extract of Viscum album (mistletoe) in hypercholesterolaemic rats was investigated in this study. The lethality studies showed that the aqueous extract of the plant had an LD50 value of 452.20mg/kg by intraperitoneal route. There were significant ...

  13. Enhanced antibody-dependent cellular phagocytosis by chimeric monoclonal antibodies with tandemly repeated Fc domains.

    Science.gov (United States)

    Nagashima, Hiroaki; Ootsubo, Michiko; Fukazawa, Mizuki; Motoi, Sotaro; Konakahara, Shu; Masuho, Yasuhiko

    2011-04-01

    We previously reported that chimeric monoclonal antibodies (mAbs) with tandemly repeated Fc domains, which were developed by introducing tandem repeats of Fc domains downstream of 2 Fab domains, augmented binding avidities for all Fcγ receptors, resulting in enhanced antibody (Ab)-dependent cellular cytotoxicity. Here we investigated regarding Ab-dependent cellular phagocytosis (ADCP) mediated by these chimeric mAbs, which is considered one of the most important mechanisms that kills tumor cells, using two-color flow cytometric methods. ADCP mediated by T3-Ab, a chimeric mAb with 3 tandemly repeated Fc domains, was 5 times more potent than that by native anti-CD20 M-Ab (M-Ab hereafter). Furthermore, T3-Ab-mediated ADCP was resistant to competitive inhibition by intravenous Ig (IVIG), although M-Ab-mediated ADCP decreased in the presence of IVIG. An Fcγ receptor-blocking study demonstrated that T3-Ab mediated ADCP via both FcγRIA and FcγRIIA, whereas M-Ab mediated ADCP exclusively via FcγRIA. These results suggest that chimeric mAbs with tandemly repeated Fc domains enhance ADCP as well as ADCC, and that Fc multimerization may significantly enhance the efficacy of therapeutic Abs. Copyright © 2010 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.

  14. FcεRI γ-Chain Negatively Modulates Dectin-1 Responses in Dendritic Cells

    Directory of Open Access Journals (Sweden)

    Yi-Gen Pan

    2017-10-01

    Full Text Available The inhibitory effect of immunoreceptor tyrosine-based activation motif (ITAM-containing adapters DAP12 and FcεRI γ-chain (FcRγ has been found in many immune functions. Herein, we have further explored the role of these adapters in C-type lectin receptors response. We identified that FcRγ, but not DAP12, could negatively regulate the Dectin-1 responses in dendritic cells (DCs. Loss of FcRγ or both DAP12 and FcRγ enhanced the maturation and cytokine production in DCs upon Dectin-1 activation compared to normal cells, whereas DCs lacking only DAP12 showed little changes. In addition, increments of T cell activation and T helper 17 polarization induced by FcRγ-deficient DCs were observed both in vitro and in vivo. Examining the Dectin-1 signaling, we revealed that the activations of several signaling molecules were augmented in FcRγ-deficient DCs stimulated with Dectin-1 ligands. Furthermore, we demonstrated that the association of phosphatases SHP-1 and PTEN with FcRγ may contribute to the negative regulation of FcRγ in Dectin-1 activation in DCs. These results extend the inhibitory effect of ITAM-containing adapters to Dectin-1 response in immune functions, even though Dectin-1 contains an ITAM-like intracellular domain. According to the role of Dectin-1 in responding to microbes and tumor cells, our finding may have applications in the development of vaccine and cancer therapy.

  15. Importance of heart rate during exercise for response to cardiac resynchronization therapy.

    Science.gov (United States)

    Maass, Alexander H; Buck, Sandra; Nieuwland, Wybe; Brügemann, Johan; van Veldhuisen, Dirk J; Van Gelder, Isabelle C

    2009-07-01

    Cardiac resynchronization therapy (CRT) is an established therapy for patients with severe heart failure and mechanical dyssynchrony. Response is only achieved in 60-70% of patients. To study exercise-related factors predicting response to CRT. We retrospectively examined consecutive patients in whom a CRT device was implanted. All underwent cardiopulmonary exercise testing prior to implantation and after 6 months. The occurrence of chronotropic incompetence and heart rates exceeding the upper rate of the device, thereby compromising biventricular stimulation, was studied. Response was defined as a decrease in LVESV of 10% or more after 6 months. We included 144 patients. After 6 months 86 (60%) patients were responders. Peak VO2 significantly increased in responders. Chronotropic incompetence was more frequently seen in nonresponders (21 [36%] vs 9 [10%], P = 0.03), mostly in patients in SR. At moderate exercise, defined as 25% of the maximal exercise tolerance, that is, comparable to daily life exercise, nonresponders more frequently went above the upper rate of the device (13 [22%] vs 2 [3%], P exercise (OR 15.8 [3.3-76.5], P = 0.001) and nonischemic cardiomyopathy (OR 2.4 [1.0-5.7], P = 0.04) as predictive for response. Heart rate exceeding the upper rate during moderate exercise is an independent predictor for nonresponse to CRT in patients with AF, whereas chronotropic incompetence is a predictor for patients in SR.

  16. Safety and efficacy of a drug regimen to control heart rate during 64-slice ECG-gated coronary CTA in children

    International Nuclear Information System (INIS)

    Rigsby, Cynthia K.; Nicholas, Angela C.; deFreitas, R.A.; Leidecker, Christianne; Johanek, Andrew J.; Anley, Peter; Wang, Deli; Uejima, Tetsu

    2010-01-01

    The adult practice for ECG-gated single-source 64-slice coronary CTA (CCTA) includes administering beta-blockers to reduce heart rate. There are limited data on this process in children. To evaluate the safety and efficacy of a drug regimen to decrease heart rate before performing CCTA in children. IV remifentanil and esmolol infusion were chosen to decrease heart rate in 41 children (mean age 6.5 years) while they were under general anesthesia (GA) for CCTA. Drug doses, changes in heart rate and procedural complications were recorded. CCTA image quality was graded on a scale of 1 to 5. The relationships between image quality and heart rate and image quality and age were evaluated. Patient effective radiation doses were calculated. Heart rates were lowered utilizing esmolol (4 children), remifentanil (2 children) or both (35 children); 26 children received nitroglycerin for coronary vasodilation. The mean decrease in heart rate was 26%. There were no major complications. The average image-quality score was 4.4. Higher heart rates were associated with worse image quality (r = 0.67, P < 0.0001). Older age was associated with better image quality (r = 0.66, P < 0.0001). Effective radiation doses were 0.7 to 7.0 mSv. Heart rate reduction for pediatric CCTA can be safely and effectively achieved while yielding high-quality images. (orig.)

  17. Attachment Status Affects Heart Rate Responses to Experimental Ostracism in Inpatients with Depression.

    Directory of Open Access Journals (Sweden)

    Jannika De Rubeis

    Full Text Available Depression is assumed to be both a risk factor for rejection and a result of it, and as such constitutes an important factor in rejection research. Attachment theory has been applied to understand psychological disorders, such as depression, and can explain individual differences in responses to rejection. Research on autonomic nervous system activity to rejection experiences has been contradictory, with opposing strings of argumentation (activating vs. numbing. We investigated autonomic nervous system-mediated peripheral physiological responses (heart rate to experimentally manipulated ostracism (Cyberball in 97 depressed patients with organized (n = 52 and disorganized attachment status (n = 45. Controlling for baseline mean heart rate levels, depressed patients with disorganized attachment status responded to ostracism with significantly higher increases in heart rate than depressed patients with organized attachment status (p = .029; ηp2 = .051. These results suggest that attachment status may be a useful indicator of autonomic responses to perceived social threat, which in turn may affect the therapeutic process and the patient-therapist relationship.

  18. Heart rate variability changes in physicians working on night call.

    Science.gov (United States)

    Malmberg, Birgitta; Persson, Roger; Flisberg, Per; Ørbaek, Palle

    2011-03-01

    Adverse effects by night-call duty have become an important occupational health issue. The aim of this study was to investigate whether the heart rate variability (HRV) differed during recovery from day work and night-call duty between distinct physician specialities. We studied the impact of a 16-h night-call duty on autonomic balance, measured by HRV, among two physician groups differing with respect to having to deal with life-threatening conditions while on call. Nineteen anaesthesiologists (ANEST) and 16 paediatricians and ear, nose and throat surgeons (PENT) were monitored by ambulatory digital Holter electrocardiogram (ECG). Heart rate variability was analysed between 21:00 and 22:00 after an ordinary workday, on night call and in the evening post-call. Absolute and normalized high-frequency power (HF, HFnu) were the main outcome variables, expressing parasympathetic influence on the heart. ANEST had lower HF power than PENT while on night call and post-daytime work (p work compared with post-night-call duty (p balance and did not differ between specialities. However, the less dynamic HRV after daytime work and during night-call duty in the ANEST group may indicate a higher physiological stress level. These results may contribute to the improvement of night-call schedules within the health care sector.

  19. The Effect of 8 Weeks Yoga Training on Respiratory Function and Heart Rate of Non-Athlete Females

    Directory of Open Access Journals (Sweden)

    KH

    2015-07-01

    Conclusions: Results of this study showed that 8 weeks of practicing yoga and pranayama to increase vital capacity and forced expiratory volume in the first second and decreased heart rate and respiratory rate at rest is. Keywords: Yoga, Pranayama, spirometric indices, heart rate

  20. Playing a violent television game affects heart rate variability.

    Science.gov (United States)

    Ivarsson, Malena; Anderson, Martin; Akerstedt, Torbjörn; Lindblad, Frank

    2009-01-01

    To investigate how playing a violent/nonviolent television game during the evening affects sympathetic and parasympathetic reactions during and after playing as well as sleep quality during the night after playing. In total, 19 boys, 12-15 years of age, played television games on two occasions in their homes and participated once without gaming. Heart rate, heart rate variability (HRV) and physical activity were measured during gaming/participating and the night to follow using a portable combined heart rate and movement sensor. A sleep diary and questionnaires about gaming experiences and session-specific experiences were filled in. Criteria for Selection of Games: Violent game involves/rewards direct physical violence (no handguns) against another person, and nonviolent game involves/rewards no violence; same game design ('third-person game'); conducted in the same manner; no differences concerning motor activity; similar sound and light effects; no sexual content, violence against women or racial overtones. During violent (vs. nonviolent) gaming, there was significantly higher activity of the very low frequency component of the HRV and total power. During the night after playing, very low frequency, low frequency and high frequency components were significantly higher during the violent (vs. nonviolent) condition, just as total power. There were no significant differences between the three conditions (violent/nonviolent/no gaming) with respect to an index reflecting subjectively perceived sleep difficulties. Nor was there any difference between violent and nonviolent condition for any single sleep item. Violent gaming induces different autonomic responses in boys compared to nonviolent gaming--during playing and during the following night--suggesting different emotional responses. Subjectively perceived sleep quality is not influenced after a single gaming experience. Future studies should address the development of the autonomic balance after gaming over longer

  1. Self-rating level of perceived exertion for guiding exercise intensity during a 12-week cardiac rehabilitation programme and the influence of heart rate reducing medication

    DEFF Research Database (Denmark)

    Tang, Lars H.; Zwisler, Ann-Dorthe; Taylor, Rod S

    2016-01-01

    OBJECTIVES: To investigate whether self-rating level of perceived exertion can adequately guide exercise intensity during a 12-week cardiac rehabilitation programme. DESIGN: Linear regression analysis using rehabilitation data from two randomised controlled trials. METHODS: Patients undergoing ra......-led and self-regulated model using rating of perceived exertion can help guide exercise intensity in everyday clinical practice among patients with heart disease, irrespective if they are taking heart rate-reducing medication....... radiofrequency ablation for atrial fibrillation or following heart valve surgery and participating in exercise-based rehabilitation were included. The 12-week rehabilitation outpatient programme comprised three weekly training sessions, each consisting of 20min aerobic exercise divided into three steps. Patients...... were asked to base their exercise intensity for each step on a predefined rating of perceived exertion specified in a training diary. Exercise intensity was objectively measured by heart rate during the last 2min for each exercise step. Comparative analysis and linear regression of the rating...

  2. Chicken IgY Fc expressed by Eimeria mitis enhances the immunogenicity of E. mitis.

    Science.gov (United States)

    Qin, Mei; Tang, Xinming; Yin, Guangwen; Liu, Xianyong; Suo, Jingxia; Tao, Geru; Ei-Ashram, Saeed; Li, Yuan; Suo, Xun

    2016-03-21

    Eimeria species are obligate intracellular apicomplexan parasites, causing great economic losses in the poultry industry. Currently wild-and attenuated- type anticoccidial vaccines are used to control coccidiosis. However, their use in fast growing broilers is limited by vaccination side effects caused by medium and/or low immunogenic Eimeria spp. There is, therefore, a need for a vaccine with high immunogenicity for broilers. The avian yolk sac IgY Fc is the avian counterpart of the mammalian IgG Fc, which enhances immunogenicity of Fc-fusion proteins. Here, we developed a stable transgenic Eimeria mitis expressing IgY Fc (Emi.chFc) and investigated whether the avian IgY Fc fragment enhances the immunogenicity of E. mitis. Two-week-old broilers were immunized with either Emi.chFc or wild type Eimeria and challenged with wild type E. mitis to analyze the protective properties of transgenic Emi.chFc. Chickens immunized with Emi.chFc had significantly lower oocyst output, in comparison with PBS, mock control (transgenic E. mitis expressing HA1 from H9N2 avian influenza virus) and wildtype E. mitis immunized groups after challenge, indicating that IgY Fc enhanced the immunogenicity of E. mitis. Our findings suggest that IgY Fc-expressing Eimeria may be a better coccidiosis vaccine, and transgenic Eimeria expressing Fc-fused exogenous antigens may be used as a novel vaccine-delivery vehicle against a wide variety of pathogens.

  3. Sudan ebolavirus long recovered survivors produce GP-specific Abs that are of the IgG1 subclass and preferentially bind FcγRI.

    Science.gov (United States)

    Radinsky, Olga; Edri, Avishay; Brusilovsky, Michael; Fedida-Metula, Shlomit; Sobarzo, Ariel; Gershoni-Yahalom, Orly; Lutwama, Julius; Dye, John; Lobel, Leslie; Porgador, Angel

    2017-07-20

    Ebolavirus is a highly lethal pathogen, causing a severe hemorrhagic disease with a high fatality rate. To better understand immune correlates of protection by virus specific IgG, we investigated the evolution of the Fcγ receptors (FcγRs)-activating capabilities of antiviral IgG in serum samples of long recovered survivors. To this end, longitudinal serum samples from survivors of Sudan ebolavirus (SUDV) infection, studied over years, were examined for the presence of Ebola-GP specific IgG subclasses, and for their binding to FcγRs. We developed a cell-based reporter system to quantitate pathogen-specific antibody binding to FcγRIIIA, FcγRIIA, FcγRIIB and FcγRI. With this system, we demonstrate that anti-GP-specific stimulation of the FcγRI reporter by survivors' sera was substantially high one year after acute infection, with a slight reduction in activity over a decade post infection. We further demonstrate that GP-specific IgG1 is by far the seroprevalent subclass that retained and even enhanced its presence in the sera, over ten years post infection; the prevalence of other GP-specific IgG subclasses was considerably reduced over time. In accordance, GP-specific FcγRI reporter response and GP-specific total IgG1 subclass correlated in the studied group of Ebola survivors. These observations are important for further informing Ebola vaccine and therapeutic development.

  4. The Influence of Motor Impairment on Autonomic Heart Rate Modulation among Children with Cerebral Palsy

    Science.gov (United States)

    Zamuner, Antonio Roberto; Cunha, Andrea Baraldi; da Silva, Ester; Negri, Ana Paola; Tudella, Eloisa; Moreno, Marlene Aparecida

    2011-01-01

    The study of heart rate variability is an important tool for a noninvasive evaluation of the neurocardiac integrity. The present study aims to evaluate the autonomic heart rate modulation in supine and standing positions in 12 children diagnosed with cerebral palsy and 16 children with typical motor development (control group), as well as to…

  5. Effects of altered FcγR binding on antibody pharmacokinetics in cynomolgus monkeys

    Science.gov (United States)

    Leabman, Maya K; Meng, Y Gloria; Kelley, Robert F; DeForge, Laura E; Cowan, Kyra J; Iyer, Suhasini

    2013-01-01

    Antibody interactions with Fcγ receptors (FcγRs), like FcγRIIIA, play a critical role in mediating antibody effector functions and thereby contribute significantly to the biologic and therapeutic activity of antibodies. Over the past decade, considerable work has been directed towards production of antibodies with altered binding affinity to FcγRs and evaluation of how the alterations modulate their therapeutic activity. This has been achieved by altering glycosylation status at N297 or by engineering modifications in the crystallizable fragment (Fc) region. While the effects of these modifications on biologic activity and efficacy have been examined, few studies have been conducted to understand their effect on antibody pharmacokinetics (PK). We present here a retrospective analysis in which we characterize the PK of three antibody variants with decreased FcγR binding affinity caused by amino acid substitutions in the Fc region (N297A, N297G, and L234A/L235A) and three antibody variants with increased FcγRIIIA binding affinity caused by afucosylation at N297, and compare their PK to corresponding wild type antibody PK in cynomolgus monkeys. For all antibodies, PK was examined at a dose that was known to be in the linear range. Since production of the N297A and N297G variants in Chinese hamster ovary cells results in aglycosylated antibodies that do not bind to FcγRs, we also examined the effect of expression of an aglycosylated antibody, without sequence change(s), in E. coli. All the variants demonstrated similar PK compared with that of the wild type antibodies, suggesting that, for the six antibodies presented here, altered FcγR binding affinity does not affect PK. PMID:24492343

  6. Validity of (Ultra-)Short Recordings for Heart Rate Variability Measurements

    NARCIS (Netherlands)

    Muñoz Venegas, Loretto; van Roon, Arie; Riese, Harriette; Thio, Chris; Oostenbroek, Emma; Westrik, Iris; de Geus, Eco J. C.; Gansevoort, Ron; Lefrandt, Joop; Nolte, Ilja M.; Snieder, Harold

    2015-01-01

    Objectives In order to investigate the applicability of routine 10s electrocardiogram (ECG) recordings for time-domain heart rate variability (HRV) calculation we explored to what extent these (ultra-)short recordings capture the "actual" HRV. Methods The standard deviation of normal-to-normal

  7. Individual variability in heart rate recovery after standardized submaximal exercise

    NARCIS (Netherlands)

    van der Does, Hendrike; Brink, Michel; Visscher, Chris; Lemmink, Koen

    2012-01-01

    To optimize performance, coaches and athletes are always looking for the right balance between training load and recovery. Therefore, closely monitoring of athletes is important. Heart rate recovery (HRR) after standardized sub maximal exercise has been proposed as a useful variable to monitor

  8. The intubating laryngeal mask produces less heart rate response to ...

    African Journals Online (AJOL)

    Pc

    We compared heart rate and blood pressure changes to intubation produced by conventional laryngoscopic-guided intubation to those produced by blind intubation through the intubating laryngeal mask (ILM) in normotensive adults with normal airways. Forty paralysed, anaesthetised adults undergoing elective surgery ...

  9. Relationship between exercise heart rate and music tempo preference

    OpenAIRE

    Karageorghis, CI; Jones, L; Low, DC

    2006-01-01

    The present study examined the predicted positive and linear relationship (Iwanaga, 1995a,1995b) between exercise heart rate and music tempo preference. Initially, 128 undergraduates (M 3 age = 20.0 years, SD = 0.9 years) were surveyed to establish their three favorite music artists of all time. A separate experimental group of 29 undergraduates (M age = 20.3 years, SD = 1.2 years) selected the music of a single artist from a choice of the three highest-rated artists from the earlier survey. ...

  10. Intermittent Auscultation for Intrapartum Fetal Heart Rate Surveillance: American College of Nurse-Midwives.

    Science.gov (United States)

    2015-01-01

    Fetal heart rate surveillance is a standard component of intrapartum care. The fetal heart rate can be evaluated using intermittent auscultation or electronic fetal monitoring. Research that has compared these 2 strategies found them to be equivalent with respect to long-term neonatal outcomes. The purpose of this clinical bulletin by the American College of Nurse-Midwives is to review the evidence for use of intermittent auscultation and provide recommendations for intermittent auscultation technique, interpretation, and documentation. © 2015 by the American College of Nurse-Midwives.

  11. Deficient maternal zinc intake-but not folate-is associated with lower fetal heart rate variability.

    Science.gov (United States)

    Spann, Marisa N; Smerling, Jennifer; Gustafsson, Hanna; Foss, Sophie; Altemus, Margaret; Monk, Catherine

    2015-03-01

    Few studies of maternal prenatal diet and child development examine micronutrient status in relation to fetal assessment. Twenty-four-hour dietary recall of zinc and folate and 20min of fetal heart rate were collected from 3rd trimester pregnant adolescents. Deficient zinc was associated with less fetal heart rate variability. Deficient folate had no associations with HRV. Neither deficient zinc nor deficient folate was related to fetal heart rate. These findings, from naturalistic observation, are consistent with emerging data on prenatal zinc supplementation using a randomized control design. Taken together, the findings suggest that maternal prenatal zinc intake is an important and novel factor for understanding child ANS development. Copyright © 2015. Published by Elsevier Ireland Ltd.

  12. Deficient maternal zinc intake—but not folate—is associated with lower fetal heart rate variability

    Science.gov (United States)

    Spann, Marisa N.; Smerling, Jennifer; Gustafsson, Hanna; Foss, Sophie; Altemus, Margaret; Monk, Catherine

    2015-01-01

    Objective Few studies of maternal prenatal diet and child development examine micronutrient status in relation to fetal assessment. Methods Twenty-four-hour dietary recall of zinc and folate and 20min of fetal heart rate were collected from 3rd trimester pregnant adolescents. Results Deficient zinc was associated with less fetal heart rate variability. Deficient folate had no associations with HRV. Neither deficient zinc nor deficient folate was related to fetal heart rate. Conclusions These findings, from naturalistic observation, are consistent with emerging data on prenatal zinc supplementation using a randomized control design. Practical Implication Taken together, the findings suggest that maternal prenatal zinc intake is an important and novel factor for understanding child ANS development. PMID:25658874

  13. Effect of Smoking on Blood Pressure and Resting Heart Rate

    DEFF Research Database (Denmark)

    Linneberg, Allan; Jacobsen, Rikke K; Skaaby, Tea

    2015-01-01

    BACKGROUND: -Smoking is an important cardiovascular disease risk factor, but the mechanisms linking smoking to blood pressure are poorly understood. METHODS AND RESULTS: -Data on 141,317 participants (62,666 never, 40,669 former, 37,982 current smokers) from 23 population-based studies were...... for smoking heaviness in current smokers. In observational analyses, current as compared with never smoking was associated with lower SBP, DBP, and lower hypertension risk, but with higher resting heart rate. In observational analyses amongst current smokers, one cigarette/day higher level of smoking...... heaviness was associated with higher (0.21 beats/minute; 95% CI 0.19; 0.24) resting heart rate, and slightly higher DBP (0.05 mmHg; 95% CI 0.02; 0.08) and SBP (0.08 mmHg; 95% CI 0.03; 0.13). However, in MR analyses amongst current smokers, while each smoking increasing allele of rs16969968/rs1051730...

  14. 40 CFR Table 25 to Subpart G of... - Effective Column Diameter (Fc)

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 9 2010-07-01 2010-07-01 false Effective Column Diameter (Fc) 25 Table..., Table 25 Table 25 to Subpart G of Part 63—Effective Column Diameter (Fc) Column type Fc (feet) 9-inch by 7-inch built-up columns 1.1 8-inch-diameter pipe columns 0.7 No construction details known 1.0 ...

  15. Retrospective low heart rate variability overview in Jos, Nigeria ...

    African Journals Online (AJOL)

    Result: Subjects with low HRV were older (51 vs 42, p=<0.05) years with low mean heart rate p=<0.05, compared to those with normal HRV. They all had severe features of cardiac dysfunction. Females with low HRV had decreased frequency of premature atrial contraction (PACs) (52% vs 78%). Only 5 (28%) cases out of ...

  16. Neighborhood blight, stress, and health: a walking trial of urban greening and ambulatory heart rate

    Science.gov (United States)

    Eugenia C. South; Michelle C. Kondo; Rose A. Cheney; Charles C. Branas

    2015-01-01

    We measured dynamic stress responses using ambulatory heart rate monitoring as participants in Philadelphia, Pennsylvania walked past vacant lots before and after a greening remediation treatment of randomly selected lots. Being in view of a greened vacant lot decreased heart rate significantly more than did being in view of a nongreened vacant lot or not in view of...

  17. Effect of Heart Rate Variability Biofeedback on Sport Performance, a Systematic Review.

    Science.gov (United States)

    Jiménez Morgan, Sergio; Molina Mora, José Arturo

    2017-09-01

    Aim is to determine if the training with heart rate variability biofeedback allows to improve performance in athletes of different disciplines. Methods such as database search on Web of Science, SpringerLink, EBSCO Academic Search Complete, SPORTDiscus, Pubmed/Medline, and PROQUEST Academic Research Library, as well as manual reference registration. The eligibility criteria were: (a) published scientific articles; (b) experimental studies, quasi-experimental, or case reports; (c) use of HRV BFB as main treatment; (d) sport performance as dependent variable; (e) studies published until October 2016; (f) studies published in English, Spanish, French or Portuguese. The guidelines of the PRISMA statement were followed. Out of the 451 records found, seven items were included. All studies had a small sample size (range from 1 to 30 participants). In 85.71% of the studies (n = 6) the athletes enhanced psychophysiological variables that allowed them to improve their sport performance thanks to training with heart rate variability biofeedback. Despite the limited amount of experimental studies in the field to date, the findings suggest that heart rate variability biofeedback is an effective, safe, and easy-to-learn and apply method for both athletes and coaches in order to improve sport performance.

  18. Effects of vasoactive intestinal polypeptide on heart rate in relation to vagal cardioacceleration in conscious dogs

    NARCIS (Netherlands)

    Roossien, A; Brunstig, J.R; Nijmeijer, A; Zaagsma, Hans; Zijlstra, W.G

    Objective: The vagal cardiac accelerator (VCA) system takes part in the nervous control of the heart rate. In the present study we tried to adduce evidence that vasoactive intestinal polypeptide (VLP) contributes to vagally induced cardioacceleration. Methods: The effect of VIP on heart rate and

  19. Humoral regulation of heart rate during digestion in pythons (Python molurus and Python regius).

    Science.gov (United States)

    Enok, Sanne; Simonsen, Lasse Stærdal; Pedersen, Signe Vesterskov; Wang, Tobias; Skovgaard, Nini

    2012-05-15

    Pythons exhibit a doubling of heart rate when metabolism increases several times during digestion. Pythons, therefore, represent a promising model organism to study autonomic cardiovascular regulation during the postprandial state, and previous studies show that the postprandial tachycardia is governed by a release of vagal tone as well as a pronounced stimulation from nonadrenergic, noncholinergic (NANC) factors. Here we show that infusion of plasma from digesting donor pythons elicit a marked tachycardia in fasting snakes, demonstrating that the NANC factor resides in the blood. Injections of the gastrin and cholecystokinin receptor antagonist proglumide had no effect on double-blocked heart rate or blood pressure. Histamine has been recognized as a NANC factor in the early postprandial period in pythons, but the mechanism of its release has not been identified. Mast cells represent the largest repository of histamine in vertebrates, and it has been speculated that mast cells release histamine during digestion. Treatment with the mast cell stabilizer cromolyn significantly reduced postprandial heart rate in pythons compared with an untreated group but did not affect double-blocked heart rate. While this study indicates that histamine induces postprandial tachycardia in pythons, its release during digestion is not stimulated by gastrin or cholecystokinin nor is its release from mast cells a stimulant of postprandial tachycardia.

  20. Heart-rate variability and precompetitive anxiety in swimmers

    OpenAIRE

    Cervantes Blásquez, Julio César

    2009-01-01

    The aim of this study was to test the utility of heart-rate variability (HRV) analyses as a noninvasive means of quantifying cardiac autonomic regulation during precompetitive anxiety situations in swimmers. Psychophysiological state evaluation of 10 volunteer «master» swimmers (6 women and 4 men) was obtained by comparing baseline training condition (TC) with competition condition (CC). Self-evaluation of precompetitive somatic anxiety measured by CSAI-2 showed significant increase from the ...

  1. Ebolavirus Glycoprotein Fc Fusion Protein Protects Guinea Pigs against Lethal Challenge

    Science.gov (United States)

    Konduru, Krishnamurthy; Shurtleff, Amy C.; Bradfute, Steven B.; Nakamura, Siham; Bavari, Sina; Kaplan, Gerardo

    2016-01-01

    Ebola virus (EBOV), a member of the Filoviridae that can cause severe hemorrhagic fever in humans and nonhuman primates, poses a significant threat to the public health. Currently, there are no licensed vaccines or therapeutics to prevent and treat EBOV infection. Several vaccines based on the EBOV glycoprotein (GP) are under development, including vectored, virus-like particles, and protein-based subunit vaccines. We previously demonstrated that a subunit vaccine containing the extracellular domain of the Ebola ebolavirus (EBOV) GP fused to the Fc fragment of human IgG1 (EBOVgp-Fc) protected mice against EBOV lethal challenge. Here, we show that the EBOVgp-Fc vaccine formulated with QS-21, alum, or polyinosinic-polycytidylic acid-poly-L-lysine carboxymethylcellulose (poly-ICLC) adjuvants induced strong humoral immune responses in guinea pigs. The vaccinated animals developed anti-GP total antibody titers of approximately 105−106 and neutralizing antibody titers of approximately 103 as assessed by a BSL-2 neutralization assay based on vesicular stomatitis virus (VSV) pseudotypes. The poly-ICLC formulated EBOVgp-Fc vaccine protected all the guinea pigs against EBOV lethal challenge performed under BSL-4 conditions whereas the same vaccine formulated with QS-21 or alum only induced partial protection. Vaccination with a mucin-deleted EBOVgp-Fc construct formulated with QS-21 adjuvant did not have a significant effect in anti-GP antibody levels and protection against EBOV lethal challenge compared to the full-length GP construct. The bulk of the humoral response induced by the EBOVgp-Fc vaccine was directed against epitopes outside the EBOV mucin region. Our findings indicate that different adjuvants can eliciting varying levels of protection against lethal EBOV challenge in guinea pigs vaccinated with EBOVgp-Fc, and suggest that levels of total anti-GP antibodies elicit by protein-based GP subunit vaccines do not correlate with protection. Our data further support

  2. Ebolavirus Glycoprotein Fc Fusion Protein Protects Guinea Pigs against Lethal Challenge.

    Science.gov (United States)

    Konduru, Krishnamurthy; Shurtleff, Amy C; Bradfute, Steven B; Nakamura, Siham; Bavari, Sina; Kaplan, Gerardo

    2016-01-01

    Ebola virus (EBOV), a member of the Filoviridae that can cause severe hemorrhagic fever in humans and nonhuman primates, poses a significant threat to the public health. Currently, there are no licensed vaccines or therapeutics to prevent and treat EBOV infection. Several vaccines based on the EBOV glycoprotein (GP) are under development, including vectored, virus-like particles, and protein-based subunit vaccines. We previously demonstrated that a subunit vaccine containing the extracellular domain of the Ebola ebolavirus (EBOV) GP fused to the Fc fragment of human IgG1 (EBOVgp-Fc) protected mice against EBOV lethal challenge. Here, we show that the EBOVgp-Fc vaccine formulated with QS-21, alum, or polyinosinic-polycytidylic acid-poly-L-lysine carboxymethylcellulose (poly-ICLC) adjuvants induced strong humoral immune responses in guinea pigs. The vaccinated animals developed anti-GP total antibody titers of approximately 105-106 and neutralizing antibody titers of approximately 103 as assessed by a BSL-2 neutralization assay based on vesicular stomatitis virus (VSV) pseudotypes. The poly-ICLC formulated EBOVgp-Fc vaccine protected all the guinea pigs against EBOV lethal challenge performed under BSL-4 conditions whereas the same vaccine formulated with QS-21 or alum only induced partial protection. Vaccination with a mucin-deleted EBOVgp-Fc construct formulated with QS-21 adjuvant did not have a significant effect in anti-GP antibody levels and protection against EBOV lethal challenge compared to the full-length GP construct. The bulk of the humoral response induced by the EBOVgp-Fc vaccine was directed against epitopes outside the EBOV mucin region. Our findings indicate that different adjuvants can eliciting varying levels of protection against lethal EBOV challenge in guinea pigs vaccinated with EBOVgp-Fc, and suggest that levels of total anti-GP antibodies elicit by protein-based GP subunit vaccines do not correlate with protection. Our data further support

  3. Ebolavirus Glycoprotein Fc Fusion Protein Protects Guinea Pigs against Lethal Challenge.

    Directory of Open Access Journals (Sweden)

    Krishnamurthy Konduru

    Full Text Available Ebola virus (EBOV, a member of the Filoviridae that can cause severe hemorrhagic fever in humans and nonhuman primates, poses a significant threat to the public health. Currently, there are no licensed vaccines or therapeutics to prevent and treat EBOV infection. Several vaccines based on the EBOV glycoprotein (GP are under development, including vectored, virus-like particles, and protein-based subunit vaccines. We previously demonstrated that a subunit vaccine containing the extracellular domain of the Ebola ebolavirus (EBOV GP fused to the Fc fragment of human IgG1 (EBOVgp-Fc protected mice against EBOV lethal challenge. Here, we show that the EBOVgp-Fc vaccine formulated with QS-21, alum, or polyinosinic-polycytidylic acid-poly-L-lysine carboxymethylcellulose (poly-ICLC adjuvants induced strong humoral immune responses in guinea pigs. The vaccinated animals developed anti-GP total antibody titers of approximately 105-106 and neutralizing antibody titers of approximately 103 as assessed by a BSL-2 neutralization assay based on vesicular stomatitis virus (VSV pseudotypes. The poly-ICLC formulated EBOVgp-Fc vaccine protected all the guinea pigs against EBOV lethal challenge performed under BSL-4 conditions whereas the same vaccine formulated with QS-21 or alum only induced partial protection. Vaccination with a mucin-deleted EBOVgp-Fc construct formulated with QS-21 adjuvant did not have a significant effect in anti-GP antibody levels and protection against EBOV lethal challenge compared to the full-length GP construct. The bulk of the humoral response induced by the EBOVgp-Fc vaccine was directed against epitopes outside the EBOV mucin region. Our findings indicate that different adjuvants can eliciting varying levels of protection against lethal EBOV challenge in guinea pigs vaccinated with EBOVgp-Fc, and suggest that levels of total anti-GP antibodies elicit by protein-based GP subunit vaccines do not correlate with protection. Our data

  4. Reductions in Children's Vicariously Learnt Avoidance and Heart Rate Responses Using Positive Modeling.

    Science.gov (United States)

    Reynolds, Gemma; Field, Andy P; Askew, Chris

    2016-03-23

    Recent research has indicated that vicarious learning can lead to increases in children's fear beliefs and avoidance preferences for stimuli and that these fear responses can subsequently be reversed using positive modeling (counterconditioning). The current study investigated children's vicariously acquired avoidance behavior, physiological responses (heart rate), and attentional bias for stimuli and whether these could also be reduced via counterconditioning. Ninety-six (49 boys, 47 girls) 7- to 11-year-olds received vicarious fear learning for novel stimuli and were then randomly assigned to a counterconditioning, extinction, or control group. Fear beliefs and avoidance preferences were measured pre- and post-learning, whereas avoidance behavior, heart rate, and attentional bias were all measured post-learning. Control group children showed increases in fear beliefs and avoidance preferences for animals seen in vicarious fear learning trials. In addition, significantly greater avoidance behavior, heart rate responding, and attentional bias were observed for these animals compared to a control animal. In contrast, vicariously acquired avoidance preferences of children in the counterconditioning group were significantly reduced post-positive modeling, and these children also did not show the heightened heart rate responding to fear-paired animals. Children in the extinction group demonstrated comparable responses to the control group; thus the extinction procedure showed no effect on any fear measures. The findings suggest that counterconditioning with positive modelling can be used as an effective early intervention to reduce the behavioral and physiological effects of vicarious fear learning in childhood.

  5. The role of abnormal fetal heart rate in scheduling chorionic villus sampling.

    Science.gov (United States)

    Yagel, S; Anteby, E; Ron, M; Hochner-Celnikier, D; Achiron, R

    1992-09-01

    To assess the value of fetal heart rate (FHR) measurements in predicting spontaneous fetal loss in pregnancies scheduled for chorionic villus sampling (CVS). A prospective descriptive study. Two hospital departments of obstetrics and gynaecology in Israel. 114 women between 9 and 11 weeks gestation scheduled for chorionic villus sampling (CVS). Fetal heart rate was measured by transvaginal Doppler ultrasound and compared with a monogram established from 75 fetuses. Whenever a normal FHR was recorded, CVS was performed immediately. 106 women had a normal FHR and underwent CVS; two of these pregnancies ended in miscarriage. In five pregnancies no fetal heart beats could be identified and fetal death was diagnosed. In three pregnancies an abnormal FHR was recorded and CVS was postponed; all three pregnancies ended in miscarriage within 2 weeks. Determination of FHR correlated with crown-rump length could be useful in predicting spontaneous miscarriage before performing any invasive procedure late in the first trimester.

  6. A strategy for bacterial production of a soluble functional human neonatal Fc receptor

    DEFF Research Database (Denmark)

    Andersen, Jan Terje; Justesen, Sune; Berntzen, Gøril

    2008-01-01

    The major histocompatibility complex (MHC) class I related receptor, the neonatal Fc receptor (FcRn), rescues immunoglobulin G (IgG) and albumin from lysosomal degradation by recycling in endothelial cells. FcRn also contributes to passive immunity by mediating transport of IgG from mother to fetus...

  7. Using heart rate to predict energy expenditure in large domestic dogs.

    Science.gov (United States)

    Gerth, N; Ruoß, C; Dobenecker, B; Reese, S; Starck, J M

    2016-06-01

    The aim of this study was to establish heart rate as a measure of energy expenditure in large active kennel dogs (28 ± 3 kg bw). Therefore, the heart rate (HR)-oxygen consumption (V˙O2) relationship was analysed in Foxhound-Boxer-Ingelheim-Labrador cross-breds (FBI dogs) at rest and graded levels of exercise on a treadmill up to 60-65% of maximal aerobic capacity. To test for effects of training, HR and V˙O2 were measured in female dogs, before and after a training period, and after an adjacent training pause to test for reversibility of potential effects. Least squares regression was applied to describe the relationship between HR and V˙O2. The applied training had no statistically significant effect on the HR-V˙O2 regression. A general regression line from all data collected was prepared to establish a general predictive equation for energy expenditure from HR in FBI dogs. The regression equation established in this study enables fast estimation of energy requirement for running activity. The equation is valid for large dogs weighing around 30 kg that run at ground level up to 15 km/h with a heart rate maximum of 190 bpm irrespective of the training level. Journal of Animal Physiology and Animal Nutrition © 2015 Blackwell Verlag GmbH.

  8. Leukocyte Populations are Associated with Heart Rate Variability After a Triathlon

    Directory of Open Access Journals (Sweden)

    Cruz Germán Hernández

    2016-12-01

    Full Text Available The purpose of this study was to analyze cellular immune components and their association with heart rate variability in triathlon athletes. Twelve athletes were included (age 36.41 ± 5.57 years, body mass 81.84 ± 10.97 kg and blood samples were taken one week before, immediately, at 2 and 48 hours, and one week after competition. Total lymphocytes and their subpopulations, neutrophils, basophils, eosinophils and monocytes were analyzed. At the same time, heart rate variability was recorded for 30 minutes using Polar Team2®. A significant difference between lymphocyte subpopulations and heart rate variability was found in the different study periods. A positive correlation was found between total lymphocytes and rMSSD (r = .736, p <0.05, CD3+ and rMSSD (r = .785, p <0.05, and CD4+ and rMSSD (r = .795, p < 0.05 at the end of the competition. After one week of competition, a negative correlation was found between eosinophils and MRR, SDNN, pNN50, and rMSSD (p <0.01; and basophils and MRR, SDNN, pNN50, and rMSSD (p <0.01; while a positive correlation was found between CD19+ (B cells and pNN50 (r = .678, p <0.05. Our results suggest that it is possible to predict the effect of training with regard to the athlete's performance.

  9. EFFECT OF FUROSEMIDE AND TORASEMIDE ON HEART RATE VARIABILITY AND VENTRICULAR RHYTHM DISORDERS IN PATIENTS WITH CHRONIC HEART FAILURE COMPLICATING ISCHEMIC HEART DISEASE: COMPARATIVE NONRANDOMIZED STUDY

    Directory of Open Access Journals (Sweden)

    H. H. Shugushev

    2010-01-01

    Full Text Available Aim. To study effect of diuretic therapy with furosemide and torasemide on heart rate variability (HRV and frequency of ventriclar rhythm disorders in patients with chronic heart failure (CHF complicating ischemic heart disease (IHD.Material and methods. Patients (n=107 with CHF III-IV functional class (NYHA complicating IHD were examined. The first group of patients received furosemide, 20-60 mg QD (n=52, the second group received torasemide, 5-20 mg QD (n=55. Analysis of heart rhythm disorders and the basic HRV indicators was performed by ECG 10-minute recordings initially and after 10 days of therapy.Results. Decrease in time and spectral HRV parameters and increase in daily number of ventricular extrasystoles was found in furosemide treated patients. Improvement of HRV parameters and reduction of daily number of ventricular rhythm disorders was found torasemide treated patients.Conclusion. Torasemide therapy improves an autonomic regulation of heart rhythm and leads to the reduction of ventricular heart rhythm disorders in patients with CHF complicating IHD.

  10. Ventilatory control of heart rate during inhalation of 5% CO2 and types of panic attacks.

    Science.gov (United States)

    Ley, R

    1991-09-01

    Differences in the magnitude of increases in heart rate during prolonged inhalation of 5% CO2 range from a mean of 25 b/min for a group of eight panic-disorder patients who panicked (Woods, Charney, Goodman, & Heninger, 1988. Archives of General Psychiatry, 45, 43-52) to zero b/min for 16 patients, eight of whom panicked (Craske & Barlow, 1990. Journal of Abnormal Psychology, 99, 302-307). What accounts for this disparity? The present paper describes how heart rate can be increased by means of voluntary overbreathing during prolonged inhalation of 5% CO2 in air. This suggests that differences in the degree of overbreathing may explain differences in the magnitude of increases in heart rate during inhalation of 5% CO2. An explanation is also offered for the curious finding that some patients experience "panic attacks" with zero increase in heart rate. Evidence suggests that this is likely to happen in cognitively based panic attacks, in contrast to hyperventilatory attacks or anticipatory attacks.

  11. Flecainide attenuates rate adaptation of ventricular repolarization in guinea-pig heart

    DEFF Research Database (Denmark)

    Osadchii, Oleg E.

    2016-01-01

    examined flecainide effect on adaptation of the QT interval and ventricular action potential duration (APD) to abrupt reductions of the cardiac cycle length. DESIGN: ECG and ventricular epicardial and endocardial monophasic APD were recorded in isolated, perfused guinea-pig heart preparations upon...... a sustained cardiac acceleration (rapid pacing for 30 s), and following a single perturbation of the cycle length evoked by extrasystolic stimulation. RESULTS: Sustained increase in heart rate was associated with progressive bi-exponential shortening of the QT interval and APD. Flecainide prolonged...

  12. Investigation of the effect of occupational noise exposure on blood pressure and heart rate of steel industry workers.

    Science.gov (United States)

    Zamanian, Zahra; Rostami, Reza; Hasanzadeh, Jafar; Hashemi, Hassan

    2013-01-01

    This study aimed to investigate the effect of noise exposure on blood pressure and heart rate of steel industry workers. In the present cross-sectional study, 50 workers were selected from a steel company in Fars province, Iran, and exposed to 85, 95, and 105 dB noise levels for 5 minutes. The participants' blood pressure and heart rate were measured using Beurer BC16 pulse meter both before and after the exposure. The study results showed no significant difference in blood pressure and heart rate before and after the exposure. However, the workers' systolic blood pressure had increased compared to before the exposure; of course, the difference was not statistically significant (P > 0.05). Besides, although the subjects' heart rate had reduced in comparison to before the exposure, the difference was not statistically significant (P > 0.05). No significant change was observed in blood pressure and heart rate after acute exposure to 85, 95, and 105 dB noise levels.

  13. Live visualization of genomic loci with BiFC-TALE.

    Science.gov (United States)

    Hu, Huan; Zhang, Hongmin; Wang, Sheng; Ding, Miao; An, Hui; Hou, Yingping; Yang, Xiaojing; Wei, Wensheng; Sun, Yujie; Tang, Chao

    2017-01-11

    Tracking the dynamics of genomic loci is important for understanding the mechanisms of fundamental intracellular processes. However, fluorescent labeling and imaging of such loci in live cells have been challenging. One of the major reasons is the low signal-to-background ratio (SBR) of images mainly caused by the background fluorescence from diffuse full-length fluorescent proteins (FPs) in the living nucleus, hampering the application of live cell genomic labeling methods. Here, combining bimolecular fluorescence complementation (BiFC) and transcription activator-like effector (TALE) technologies, we developed a novel method for labeling genomic loci (BiFC-TALE), which largely reduces the background fluorescence level. Using BiFC-TALE, we demonstrated a significantly improved SBR by imaging telomeres and centromeres in living cells in comparison with the methods using full-length FP.

  14. Peculiarities of vegetative regulation of heart rate in wrestlers of different age groups

    Directory of Open Access Journals (Sweden)

    E.B. Zapovitriana

    2015-04-01

    Full Text Available Purpose : the aim of the work was to study the characteristics of vegetative regulation of cardiac rhythm in athletes of high qualification of different age groups. Material : 26 wrestlers of Greco-Roman style of high qualification aged 19-34 years old were studied. Vegetative regulation was assessed by statistical analysis of heart rate variability using cardiac monitors «Polar RS800CX». Results : the results showed that the wrestlers of older age group has a greater level of tension of regulation of heart rhythm for compared with young athletes. This is confirmed by the reduced values of the mean square deviation RR- intervals and triangular index. According to the results of spectral analysis of cardio revealed activation of parasympathetic tone of the autonomic regulation of the heart rhythm of wrestlers in older age group, compared with young athletes. The increase of tension of regulation of heart rate in the wrestlers of older age group accompanied by a slowdown of aperiodic and periodic oscillations of cardio intervals. Conclusions: the high level of tension of regulation of heart rhythm in older wrestlers group (26-34 accompanied by the activation of neurohumoral centers and parasympathetic link of vegetative nervous system.

  15. [Voluntary alpha-power increasing training impact on the heart rate variability].

    Science.gov (United States)

    Bazanova, O M; Balioz, N V; Muravleva, K B; Skoraia, M V

    2013-01-01

    In order to study the effect of the alpha EEG power increasing training at heart rate variability (HRV) as the index of the autonomic regulation of cognitive functions there were follow tasks: (1) to figure out the impact of biofeedback in the voluntary increasing the power in the individual high-frequency alpha-band effect on heart rate variability and related characteristics of cognitive and emotional spheres, (2) to determine the nature of the relationship between alpha activity indices and heart rate variability, depending on the alpha-frequency EEG pattern at rest (3) to examine how the individual alpha frequency EEG pattern is reflected in changes HRV as a result of biofeedback training. Psychometric indicators of cognitive performance, the characteristics of the alpha-EEG activity and heart rate variability (HRV) as LF/HF and pNN50 were recorded in 27 healthy men aged 18-34 years, before, during, and after 10 sessions of training of voluntary increase in alpha power in the individual high-frequency alpha band with eyes closed. To determine the biofeedback effect on the alpha power increasing training, data subjects are compared in 2 groups: experimental (14) with the real and the control group (13 people)--with mock biofeedback. The follow up effect of trainings was studied through month over the 10 training sessions. Results showed that alpha biofeedback training enhanced the fluency and accuracy in cognitive performance, decreased anxiety and frontal EMG, increased resting frequency, width and power in individual upper alpha range only in participants with low baseline alpha frequency. While mock biofeedback increased resting alpha power only in participants with high baseline resting alpha frequency and did change neither cognitive performance, nor HRV indices. Biofeedback training eliminated the alpha power decrease in response to arithmetic task in both with high and low alpha frequency participants and this effect was followed up over the month. Mock

  16. State-related differences in heart rate variability in bipolar disorder

    DEFF Research Database (Denmark)

    Faurholt-Jepsen, Maria; Brage, Søren; Kessing, Lars Vedel

    2017-01-01

    Heart rate variability (HRV) is a validated measure of sympato-vagal balance in the autonomic nervous system. HRV appears decreased in patients with bipolar disorder (BD) compared with healthy individuals, but the extent of state-related alterations has been sparingly investigated. The present...... bipolar disorder and could...

  17. Influence of heart rate on image quality of 64-slice spiral computed coronary angiography and optimization on reconstruction of phase window

    International Nuclear Information System (INIS)

    Luo Xuemao; Lan Yong; Li Wei; Long Wansheng; Zhang Chaotong; Zhong Xiangyang; Yi Lan

    2009-01-01

    Objective: To evaluate the influence of heart rate on the image quality of 64-slice spiral computed coronary angiography (MSCTCA) and optimize the image reconstruction window. Methods: According to the heart rate, 86 patients were classified into 5 groups: group A, the heart rate ≤60 beat per minute(BMP); group B,61-70BMP, group C,71-80BMP, and group D>80BMP. The image quality of MSCTCA was scored 5 grades from 1-5 according to heart motion artifact. The influences of heart rate and reconstruction phase on the image quality of MSCTCA were evaluated. Results: Average heart rate was 64.4 ±10.1BMP. Diagnostic image quality (score>3) was attained in 277 of 344 segments at the best reconstruction interval. There was a significant corxelation between average heart rate and image quality, but there was no difference between relative delay (%) reconstruction and absolute delay (ms) reconstruction on the image quality. Conclusion: Reducing average heart rate is beneficial for improving the image quality. (authors)

  18. Prophylactic anti-D preparations display variable decreases in Fc-fucosylation of anti-D.

    NARCIS (Netherlands)

    Kapur, R.; Della Valle, L.; Verhagen, O.J.; Hipgrave Ederveen, A.; Ligthart, P.; de Haas, M.; Kumpel, B.; Wuhrer, M.; van der Schoot, C.E.; Vidarsson, G.

    2015-01-01

    Background RhIG is obtained from hyperimmunized healthy anti-D donors (HIDs) boosted with D+ red blood cells (RBCs). One hypothesis for its mechanism of action is fast clearance of opsonized D+ RBCs through Fcγ receptor (FcγR)III. Levels of immunoglobulin (Ig)G Fc-fucosylation influence interactions

  19. Prophylactic anti-D preparations display variable decreases in Fc-fucosylation of anti-D

    NARCIS (Netherlands)

    Kapur, Rick; Della Valle, Luciana; Verhagen, Onno J. H. M.; Hipgrave Ederveen, Agnes; Ligthart, Peter; de Haas, Masja; Kumpel, Belinda; Wuhrer, Manfred; van der Schoot, C. Ellen; Vidarsson, Gestur

    2015-01-01

    RhIG is obtained from hyperimmunized healthy anti-D donors (HIDs) boosted with D+ red blood cells (RBCs). One hypothesis for its mechanism of action is fast clearance of opsonized D+ RBCs through Fcγ receptor (FcγR)III. Levels of immunoglobulin (Ig)G Fc-fucosylation influence interactions with

  20. Effects of microparticle size and Fc density on macrophage phagocytosis.

    Directory of Open Access Journals (Sweden)

    Patricia Pacheco

    Full Text Available Controlled induction of phagocytosis in macrophages offers the ability to therapeutically regulate the immune system as well as improve delivery of chemicals or biologicals for immune processing. Maximizing particle uptake by macrophages through Fc receptor-mediated phagocytosis could lead to new delivery mechanisms in drug or vaccine development. Fc ligand density and particle size were examined independently and in combination in order to optimize and tune the phagocytosis of opsonized microparticles. We show the internalization efficiency of small polystyrene particles (0.5 µm to 2 µm is significantly affected by changes in Fc ligand density, while particles greater than 2 µm show little correlation between internalization and Fc density. We found that while macrophages can efficiently phagocytose a large number of smaller particles, the total volume of phagocytosed particles is maximized through the non-specific uptake of larger microparticles. Therefore, larger microparticles may be more efficient at delivering a greater therapeutic payload to macrophages, but smaller opsonized microparticles can deliver bio-active substances to a greater percentage of the macrophage population. This study is the first to treat as independent variables the physical and biological properties of Fc density and microparticle size that initiate macrophage phagocytosis. Defining the physical and biological parameters that affect phagocytosis efficiency will lead to improved methods of microparticle delivery to macrophages.

  1. Comparison of the measurement of heart rate in adult free-range chickens (Gallus domesticus) by auscultation and electrocardiography.

    Science.gov (United States)

    Smith, C F; Gavaghan, B J; McSweeney, D; Powell, V; Lisle, A

    2014-12-01

    To compare the heart rates of adult free-range chickens (Gallus domesticus) measured by auscultation with a stethoscope with those measured simultaneously using electrocardiography (ECG). With each bird in a standing position, estimation of the heart rate was performed by placing a mark on paper for every 4 beats for roosters and 8 beats for hens as detected by auscultation over 30 s, while simultaneous ECG was performed. Heart rates measured by auscultation showed a high correlation (r = 0.97) with those measured by ECG. There was a high correlation between the heart rates of adult free-range chickens measured by auscultation with a stethoscope and those measured simultaneously using ECG. © 2014 Australian Veterinary Association.

  2. Increased heart rate variability during nondirective meditation.

    Science.gov (United States)

    Nesvold, Anders; Fagerland, Morten W; Davanger, Svend; Ellingsen, Øyvind; Solberg, Erik E; Holen, Are; Sevre, Knut; Atar, Dan

    2012-08-01

    Meditation practices are in use for relaxation and stress reduction. Some studies indicate beneficial cardiovascular health effects of meditation. The effects on the autonomous nervous system seem to vary among techniques. The purpose of the present study was to identify autonomic nerve activity changes during nondirective meditation. Heart rate variability (HRV), blood pressure variability (BPV), and baroreflex sensitivity (BRS) were monitored in 27 middle-aged healthy participants of both genders, first during 20 min regular rest with eyes closed, thereafter practising Acem meditation for 20 min. Haemodynamic and autonomic data were collected continuously (beat-to-beat) and non-invasively. HRV and BPV parameters were estimated by power spectral analyses, computed by an autoregressive model. Spontaneous activity of baroreceptors were determined by the sequence method. Primary outcomes were changes in HRV, BPV, and BRS between rest and meditation. HRV increased in the low-frequency (LF) and high-frequency (HF) bands during meditation, compared with rest (p = 0.014, 0.013, respectively). Power spectral density of the RR-intervals increased as well (p = 0.012). LF/HF ratio decreased non-significantly, and a reduction of LF-BPV power was observed during meditation (p < 0.001). There was no significant difference in BRS. Respiration and heart rates remained unchanged. Blood pressure increased slightly during meditation. There is an increased parasympathetic and reduced sympathetic nerve activity and increased overall HRV, while practising the technique. Hence, nondirective meditation by the middle aged may contribute towards a reduction of cardiovascular risk.

  3. Electron-beam CT coronary angiography in the patients with high heart rate arrhythmia or pacemaker

    International Nuclear Information System (INIS)

    Dong Zhi; Zhu Jiemin; Liu Zhe; Liu Junbo; Li Youjie; Qi Ji

    2006-01-01

    Objective: To report the clinical applicability of coronary angiography for patients with high heart rate, arrhythmia or cardiac pacing using the new-generation of electron-beam CT (e-Speed). Methods: EBCT (GE e-Speed) coronary angiography was performed in 36 eases (male 27, female 9, mean age 58), including the heart rate more than 90 bpm in 20 patients, frequent ectopic beats in 11 cases, implantation of cardiac pacemaker in 4 patients and the unacceptable MSCT image quality due to variability of interscan heart rate (from 82 bpm to 104 bpm) in 1 case. After volume data set was acquired using spiral mode with prospective ECG-gating, the reconstructions of MIP, CPR, VR and Cine were performed. The VR quality was evaluated using a five-point scale. Results: The quality of coronary imaging in all of 36 cases were acceptable. The total visualization rate of coronary artery branches was 80.0%. Left main, left anterior artery and right coronary artery were visualized in all patients and in 94.3% of all cases circumflex artery were visible. Conclusion: EBCT (e-Speed) is applicable in noninvasive coronary angiography for patients with high heart rate, arrhythmia or implanted cardiac pacemaker', and this examination can obtain satisfied diagnosis. (authors)

  4. Increased heart rate variability in mice overexpressing the Cu/Zn superoxide dismutase.

    Science.gov (United States)

    Thireau, Jérôme; Poisson, Denise; Zhang, Bei Li; Gillet, Ludovic; Le Pécheur, Marie; Andres, Christian; London, Jacqueline; Babuty, Dominique

    2008-08-15

    Cu/Zn superoxide dismutase (SOD1) is implicated in various pathological conditions including Down's syndrome, neurodegenerative diseases, and afflictions of the autonomic nervous system (ANS). To assess the SOD1 contribution to ANS dysfunction, especially its influence on cardiac regulation, we studied the heart rate variability (HRV) and cardiac arrhythmias in conscious 12-month-old male and female transgenic mice for the human SOD1 gene (TghSOD1). TghSOD1 mice presented heart rate reduction as compared with control FVB/N individuals. All HRV parameters reflecting parasympathetic activity were increased in TghSOD1. Pharmacological studies confirmed that the parasympathetic tone was exacerbated and the sympathetic pathway was functional in TghSOD1 mice. A high frequency of atrioventricular block and premature ventricular contractions was observed in TghSOD1. By biochemical assays we found that SOD1 activities were multiplied by 9 and 4 respectively in the heart and brainstem of transgenic mice. A twofold decrease in cholinesterase activity was observed in the heart but not in the brainstem. We demonstrate that SOD1 overexpression induces an ANS dysfunction by an exacerbated vagal tone that may be related to impaired cardiac activity of the cholinesterases and may explain the high occurrence of arrhythmias.

  5. The progressive onset of cholinergic and adrenergic control of heart rate during development in the green iguana, Iguana iguana.

    Science.gov (United States)

    Sartori, Marina R; Leite, Cleo A C; Abe, Augusto S; Crossley, Dane A; Taylor, Edwin W

    2015-10-01

    The autonomic control of heart rate was studied throughout development in embryos of the green iguana, Iguana iguana by applying receptor agonists and antagonists of the parasympathetic and sympathetic systems. Acetylcholine (Ach) slowed or stopped the heart and atropine antagonized the response to Ach indicating the presence of muscarinic cholinoceptors on the heart of early embryos. However, atropine injections had no impact on heart rate until immediately before hatching, when it increased heart rate by 15%. This cholinergic tonus increased to 34% in hatchlings and dropped to 24% in adult iguanas. Although epinephrine was without effect, injection of propranolol slowed the heart throughout development, indicating the presence of β-adrenergic receptors on the heart of early embryos, possibly stimulated by high levels of circulating catecholamines. The calculated excitatory tonus varied between 33% and 68% until immediately before hatching when it fell to 25% and 29%, a level retained in hatchlings and adults. Hypoxia caused a bradycardia in early embryos that was unaffected by injection of atropine indicating that hypoxia has a direct effect upon the heart. In later embryos and hatchlings hypoxia caused a tachycardia that was unaffected by injection of atropine. Subsequent injection of propranolol reduced heart rate both uncovering a hypoxic bradycardia in late embryos and abolishing tachycardia in hatchlings. Hypercapnia was without effect on heart rate in late stage embryos and in hatchlings. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. Increasing T-type calcium channel activity by β-adrenergic stimulation contributes to β-adrenergic regulation of heart rates.

    Science.gov (United States)

    Li, Yingxin; Zhang, Xiaoxiao; Zhang, Chen; Zhang, Xiaoying; Li, Ying; Qi, Zhao; Szeto, Christopher; Tang, Mingxin; Peng, Yizhi; Molkentin, Jeffery D; Houser, Steven R; Xie, Mingxing; Chen, Xiongwen

    2018-04-01

    Cav3.1 T-type Ca 2+ channel current (I Ca-T ) contributes to heart rate genesis but is not known to contribute to heart rate regulation by the sympathetic/β-adrenergic system (SAS). We show that the loss of Cav3.1 makes the beating rates of the heart in vivo and perfused hearts ex vivo, as well as sinoatrial node cells, less sensitive to β-adrenergic stimulation; it also renders less conduction acceleration through the atrioventricular node by β-adrenergic stimulation. Increasing Cav3.1 in cardiomyocytes has the opposite effects. I Ca-T in sinoatrial nodal cells can be upregulated by β-adrenergic stimulation. The results of the present study add a new contribution to heart rate regulation by the SAS system and provide potential new mechanisms for the dysregulation of heart rate and conduction by the SAS in the heart. T-type Ca 2+ channel can be a target for heart disease treatments that aim to slow down the heart rate ABSTRACT: Cav3.1 (α 1G ) T-type Ca 2+ channel (TTCC) is expressed in mouse sinoatrial node cells (SANCs) and atrioventricular (AV) nodal cells and contributes to heart rate (HR) genesis and AV conduction. However, its role in HR regulation and AV conduction acceleration by the β-adrenergic system (SAS) is unclear. In the present study, L- (I Ca-L ) and T-type (I Ca-T ) Ca 2+ currents were recorded in SANCs from Cav3.1 transgenic (TG) and knockout (KO), and control mice. I Ca-T was absent in KO SANCs but enhanced in TG SANCs. In anaesthetized animals, different doses of isoproterenol (ISO) were infused via the jugular vein and the HR was recorded. The EC 50 of the HR response to ISO was lower in TG mice but higher in KO mice, and the maximal percentage of HR increase by ISO was greater in TG mice but less in KO mice. In Langendorff-perfused hearts, ISO increased HR and shortened PR intervals to a greater extent in TG but to a less extent in KO hearts. KO SANCs had significantly slower spontaneous beating rates than control SANCs before and after

  7. Heart rate turbulence and variability in patients with ventricular arrhythmias

    Directory of Open Access Journals (Sweden)

    Diego Tarricone

    2009-08-01

    Full Text Available Background: To evaluate the changes in autonomic neural control mechanisms before malignant ventricular arrhythmias, we measured heart rate variability (HRV and heart rate turbulence (HRT in patients with ventricular tachycardia or fibrillation (Group I; n=6, non sustained ventricular tachycardia (Group II; n=32, frequent premature ventricular beats (Group III; n=26 and with ICD implantation (Group IV; n=11. Methods: Time domain parameters of HRV and turbulence onset (TO and slope (TS were calculated on 24 hour Holter recordings. Normal values were: SDNN > 70 msec for HRV, TO <0% and TS >2.5 msec/RR-I for HRT. Results: Whereas SDNN was within normal range and similar in all study groups, HRT parameters were significantly different in patients who experienced VT/VF during Holter recording. Abnormal TO and/or TS were present in 100% of Group I patients and only in about 50% of Group II and IV. On the contrary, normal HRT parameters were present in 40-70% of Group II, III and IV patients and none of Group I. Conclusions: These data suggest that HRT analysis is more suitable than HRV to detect those transient alterations in autonomic control mechanisms that are likely to play a major trigger role in the genesis of malignant cardiac arrhythmias. (Heart International 2007; 3: 51-7

  8. Changes in heart rate variability are associated with expression of short-term and long-term contextual and cued fear memories.

    Directory of Open Access Journals (Sweden)

    Jun Liu

    Full Text Available Heart physiology is a highly useful indicator for measuring not only physical states, but also emotional changes in animals. Yet changes of heart rate variability during fear conditioning have not been systematically studied in mice. Here, we investigated changes in heart rate and heart rate variability in both short-term and long-term contextual and cued fear conditioning. We found that while fear conditioning could increase heart rate, the most significant change was the reduction in heart rate variability which could be further divided into two distinct stages: a highly rhythmic phase (stage-I and a more variable phase (stage-II. We showed that the time duration of the stage-I rhythmic phase were sensitive enough to reflect the transition from short-term to long-term fear memories. Moreover, it could also detect fear extinction effect during the repeated tone recall. These results suggest that heart rate variability is a valuable physiological indicator for sensitively measuring the consolidation and expression of fear memories in mice.

  9. Relationship between exercise heart rate and music tempo preference.

    Science.gov (United States)

    Karageorghis, Costas I; Jones, Leighton; Low, Daniel C

    2006-06-01

    The present study examined the predicted positive and linear relationship (Iwanaga, 1995a, 1995b) between exercise heart rate and music tempo preference. Initially, 128 undergraduate students (M age = 20.0 years, SD = 0.9) were surveyed to establish their three favorite music artists. A separate experimental group of 29 undergraduates (M age = 20.3 years, SD = 1.2) selected the music of a single artist from the three highest-rated artists from the earlier survey. They reported their preference for slow, medium, and fast tempo selections from each artist for three treadmill walking conditions at 40%, 60%, and 75% maximal heart rate reserve. A mixed-model 3 x 3 x 2 (Exercise Intensity x Music Tempo x Gender) analysis of variance was used to analyze the data. Results indicated there was no three-way interaction for music preference. There was, however, a significant (p Music Tempo (partial eta2 = .09) and a significant (p effect for music tempo, with large differences evident between preference for medium versus slow tempo and fast versus slow tempo music at all exercise intensities (partial eta2 = .78). Participants reported a preference for both medium and fast tempo music at low and moderate exercise intensities and for fast tempo music at high intensity. Only partial support was found for the expected linear relationship between exercise intensity and music tempo preference.

  10. Win some, lose some: parental hypertension and heart rate change in an incentive versus response cost paradigm.

    Science.gov (United States)

    Hastrup, J L; Johnson, C A; Hotchkiss, A P; Kraemer, D L

    1986-11-01

    Fowles (1983), citing evidence from separate studies, suggests that both incentive and response cost paradigms increase heart rate and should be subsumed under Gray's (1975) 'appetitive motivational system'. Shock avoidance and loss of reward (response cost) contingencies, while aversive, appear to evoke this motivational system; consequently both should elicit heart rate increases independent of anxiety. The present investigation compared magnitude of heart rate changes observed under conditions of winning and losing money. Results showed: no differences between incentive and response cost conditions; no effect of state anxiety on heart rate in these conditions, despite an elevation of state anxiety on the task day relative to a subsequent relaxation day assessment; and some evidence for the presence under both such appetitive conditions of cardiovascular hyperresponsivity among offspring of hypertensive parents. The results suggest a need for systematic parametric studies of experimental conditions.

  11. Is meditation always relaxing? Investigating heart rate, heart rate variability, experienced effort and likeability during training of three types of meditation.

    Science.gov (United States)

    Lumma, Anna-Lena; Kok, Bethany E; Singer, Tania

    2015-07-01

    Meditation is often associated with a relaxed state of the body. However, meditation can also be regarded as a type of mental task and training, associated with mental effort and physiological arousal. The cardiovascular effects of meditation may vary depending on the type of meditation, degree of mental effort, and amount of training. In the current study we assessed heart rate (HR), high-frequency heart rate variability (HF-HRV) and subjective ratings of effort and likeability during three types of meditation varying in their cognitive and attentional requirements, namely breathing meditation, loving-kindness meditation and observing-thoughts meditation. In the context of the ReSource project, a one-year longitudinal mental training study, participants practiced each meditation exercise on a daily basis for 3 months. As expected HR and effort were higher during loving-kindness meditation and observing-thoughts meditation compared to breathing meditation. With training over time HR and likeability increased, while HF-HRV and the subjective experience of effort decreased. The increase in HR and decrease in HF-HRV over training was higher for loving-kindness meditation and observing-thoughts meditation compared to breathing meditation. In contrast to implicit beliefs that meditation is always relaxing and associated with low arousal, the current results show that core meditations aiming at improving compassion and meta-cognitive skills require effort and are associated with physiological arousal compared to breathing meditation. Overall these findings can be useful in making more specific suggestions about which type of meditation is most adaptive for a given context and population. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Early Embryonic Heart Rate in Normal Pregnancies In Memory of ...

    African Journals Online (AJOL)

    To determine the appearance and development of embryonic heart rate a total of n = 317 Nigerian pregnant women were studied in the very early pregnancy from 23 – 56 days from the onset of last menstrual period (LMP). All pregnancies had a subsequent successful outcome. Transvaginal ultrasonography was ...

  13. Prediction of maximal heart rate: comparison using a novel and ...

    African Journals Online (AJOL)

    Prediction of maximal heart rate: comparison using a novel and conventional equation. LR Keytel, E Mukwevho, MA Will, M Lambert. Abstract. No Abstract. African Journal for Physical, Health Education, Recreation and Dance Vol. 11(3) 2005: 269-277. Full Text: EMAIL FULL TEXT EMAIL FULL TEXT · DOWNLOAD FULL ...

  14. Diagnostic performance of dual-source CT coronary angiography with and without heart rate control: Systematic review and meta-analysis

    International Nuclear Information System (INIS)

    Li, M.; Zhang, G.-M.; Zhao, J.-S.; Jiang, Z.-W.; Peng, Z.-H.; Jin, Z.-T.; Sun, G.

    2014-01-01

    Aim: To investigate the diagnostic accuracy of dual-source computed tomography (DSCT) coronary angiography with and without the application of a β-blocker. Materials and methods: An exact binomial rendition of the bivariate mixed-effects regression model was used to synthesize diagnostic test data. Results: The pooled sensitivity at the patient level was 0.98 [95% confidence intervals (CI): 0.97–0.99], and specificity 0.88 (95% CI: 0.84–0.91). The results showed that without heart rate control, the sensitivity and specificity at the patient level did not decrease (p = 0.27 and 0.56, respectively). At the artery level, no significant differences in sensitivity and specificity for studies with and without heart rate control were detected (p = 0.04 and 0.05, respectively). At the segment level, the specificity decreased without heart rate control (p = 0.03), whereas the sensitivity was not influenced (p = 0.63). The median radiation exposure was 2.6 mSv, with 1.6 mSv and 8 mSv for heart rate-controlled studies and uncontrolled studies, respectively. Conclusions: DSCT coronary angiography without heart rate control has a similar excellent diagnostic performance at the patient level as that of heart rate control groups. However, controlling for heart rate to decrease radiation and to provide effective information for selecting the therapeutic strategy and risk stratification is recommended

  15. Effects of two newly synthesized analogues of lidocaine on rat arterial blood pressure and heart rate.

    Science.gov (United States)

    Al Rasheed, N M; Al Sayed, M I; Al Zuhair, H H; Al Obaid, A R; Fatani, A J

    2001-04-01

    Two new analogues of lidocaine were synthesized at the College of Pharmacy, King Saud University: compound I (Methyl-2-[2-(N,N-diethylamino) acetamido]-3-cyano-4,5-dimethylbenzoate) and compound II (Methyl-2-[2-(piperidino) acetamido]-3-cyano-4,5-dimethylbenzoate). Their influence on the arterial blood pressure and the heart rate of urethane-anaesthetized rats was studied and compared with the actions of lidocaine. Compounds I, II and lidocaine induced significant dose-dependent decreases in the arterial blood pressure and heart rate, which usually returned to basal values within 3-5 min. There were significant differences in the potency of the three compounds in producing their effects on blood pressure and heart rate (Plidocaine and compound I, respectively. The results of this study also indicated the ineffectiveness of antagonists of autonomic, histaminergic and 5-HT receptor, and various vasodilators in blocking the actions of the three compounds on blood pressure and heart rate. Pretreatment with CaCl(2)significantly reduced the hypotension and bradycardia induced by the three compounds, suggesting the involvement of calcium channels, probably of the L type. Several possible mechanisms are postulated. In conclusion, the results direct attention to the capability of the two new compounds to decrease blood pressure and heart rate; affects that may have clinical potential. Copyright 2001 Academic Press.

  16. A single dose of dark chocolate increases parasympathetic modulation and heart rate variability in healthy subjects

    Directory of Open Access Journals (Sweden)

    Ana Amélia Machado DUARTE

    Full Text Available ABSTRACT Objective: The aim of this study was to investigate the acute effect of a single dose of dark chocolate (70% cocoa on blood pressure and heart rate variability. Methods: Thirty-one healthy subjects (aged 18-25 years; both sexes were divided into two groups: 10 subjects in the white chocolate (7.4 g group and 21 in the dark chocolate (10 g group; measurements were performed at the university's physiology lab. An electrocardiogram measured the sympathovagal balance by spectral and symbolic analysis. Results: A single dose of dark chocolate significantly reduced systolic blood pressure and heart rate. After consuming 10 g of dark chocolate, significant increases were observed for heart rate variability, standard deviation of RR intervals standard deviation of all NN intervals, square root of the mean squared differences between adjacent normal RR intervals root mean square of successive differences, and an increase in the high frequency component in absolute values, representing the parasympathetic modulation. Conclusion: In conclusion the importance of our results lies in the magnitude of the response provoked by a single dose of cocoa. Just 10 g of cocoa triggered a significant increase in parasympathetic modulation and heart rate variability. These combined effects can potentially increase life expectancy because a reduction in heart rate variability is associated with several cardiovascular diseases and higher mortality.

  17. Rate control management of atrial fibrillation: may a mathematical model suggest an ideal heart rate?

    Directory of Open Access Journals (Sweden)

    Matteo Anselmino

    Full Text Available Despite the routine prescription of rate control therapy for atrial fibrillation (AF, clinical evidence demonstrating a heart rate target is lacking. Aim of the present study was to run a mathematical model simulating AF episodes with a different heart rate (HR to predict hemodynamic parameters for each situation.The lumped model, representing the pumping heart together with systemic and pulmonary circuits, was run to simulate AF with HR of 50, 70, 90, 110 and 130 bpm, respectively.Left ventricular pressure increased by 57%, from 33.92±37.56 mmHg to 53.15±47.56 mmHg, and mean systemic arterial pressure increased by 27%, from 82.66±14.04 mmHg to 105.3±7.6 mmHg, at the 50 and 130 bpm simulations, respectively. Stroke volume (from 77.45±8.50 to 39.09±8.08 mL, ejection fraction (from 61.10±4.40 to 39.32±5.42% and stroke work (SW, from 0.88±0.04 to 0.58±0.09 J decreased by 50, 36 and 34%, at the 50 and 130 bpm simulations, respectively. In addition, oxygen consumption indexes (rate pressure product - RPP, tension time index per minute - TTI/min, and pressure volume area per minute - PVA/min increased from the 50 to the 130 bpm simulation, respectively, by 186% (from 5598±1939 to 15995±3219 mmHg/min, 56% (from 2094±265 to 3257±301 mmHg s/min and 102% (from 57.99±17.90 to 117.4±26.0 J/min. In fact, left ventricular efficiency (SW/PVA decreased from 80.91±2.91% at 50 bpm to 66.43±3.72% at the 130 bpm HR simulation.Awaiting compulsory direct clinical evidences, the present mathematical model suggests that lower HRs during permanent AF relates to improved hemodynamic parameters, cardiac efficiency, and lower oxygen consumption.

  18. Rate control management of atrial fibrillation: may a mathematical model suggest an ideal heart rate?

    Science.gov (United States)

    Anselmino, Matteo; Scarsoglio, Stefania; Camporeale, Carlo; Saglietto, Andrea; Gaita, Fiorenzo; Ridolfi, Luca

    2015-01-01

    Despite the routine prescription of rate control therapy for atrial fibrillation (AF), clinical evidence demonstrating a heart rate target is lacking. Aim of the present study was to run a mathematical model simulating AF episodes with a different heart rate (HR) to predict hemodynamic parameters for each situation. The lumped model, representing the pumping heart together with systemic and pulmonary circuits, was run to simulate AF with HR of 50, 70, 90, 110 and 130 bpm, respectively. Left ventricular pressure increased by 57%, from 33.92±37.56 mmHg to 53.15±47.56 mmHg, and mean systemic arterial pressure increased by 27%, from 82.66±14.04 mmHg to 105.3±7.6 mmHg, at the 50 and 130 bpm simulations, respectively. Stroke volume (from 77.45±8.50 to 39.09±8.08 mL), ejection fraction (from 61.10±4.40 to 39.32±5.42%) and stroke work (SW, from 0.88±0.04 to 0.58±0.09 J) decreased by 50, 36 and 34%, at the 50 and 130 bpm simulations, respectively. In addition, oxygen consumption indexes (rate pressure product - RPP, tension time index per minute - TTI/min, and pressure volume area per minute - PVA/min) increased from the 50 to the 130 bpm simulation, respectively, by 186% (from 5598±1939 to 15995±3219 mmHg/min), 56% (from 2094±265 to 3257±301 mmHg s/min) and 102% (from 57.99±17.90 to 117.4±26.0 J/min). In fact, left ventricular efficiency (SW/PVA) decreased from 80.91±2.91% at 50 bpm to 66.43±3.72% at the 130 bpm HR simulation. Awaiting compulsory direct clinical evidences, the present mathematical model suggests that lower HRs during permanent AF relates to improved hemodynamic parameters, cardiac efficiency, and lower oxygen consumption.

  19. Evidence that BDNF regulates heart rate by a mechanism involving increased brainstem parasympathetic neuron excitability

    OpenAIRE

    Wan, Ruiqian; Weigand, Letitia A.; Bateman, Ryan; Griffioen, Kathleen; Mendelowitz, David; Mattson, Mark P.

    2014-01-01

    Autonomic control of heart rate is mediated by cardioinhibitory parasympathetic cholinergic neurons located in the brainstem and stimulatory sympathetic noradrenergic neurons. During embryonic development the survival and cholinergic phenotype of brainstem autonomic neurons is promoted by brain-derived neurotrophic factor (BDNF). We now provide evidence that BDNF regulates heart rate by a mechanism involving increased brainstem cardioinhibitory parasympathetic activity. Mice with a BDNF haplo...

  20. Induction of functional Fc receptors in P388 leukemia cells. Requirement for multiple differentiation signals.

    Science.gov (United States)

    Cohen, D A; Stotelmyer, N L; Kaplan, A M

    1985-04-01

    The development of functional Fc receptors (FcR) during induced differentiation with the tumor promoter, phorbol myristate acetate (PMA), was studied in the murine tumor cell line, P388. PMA induced the appearance of FcR on the membranes of P388 cells as indicated by the binding of IgG-coated sheep red blood cells (IgG-SRBC). Concentrations of PMA as low as 1 ng/ml were sufficient to induce the expression of FcR as well as to inhibit cellular division and to induce adherence in the P388 tumor cell line; however, optimal FcR induction occurred at PMA concentrations of 10-100 ng/ml. Immunofluorescent analysis with heat-aggregated myeloma proteins indicated that PMA induced FcR which were capable of binding IgG2a and IgG2b immunoglobulins, but not IgG1. Adherence to a substratum was determined to be a second required signal for expression of FcR, since PMA induction of P388 tumor cells in teflon dishes failed to fully develop FcR and adherence of P388 cells to poly-L-lysine-coated culture dishes in the absence of PMA was insufficient for FcR expression. FcR which appeared after PMA induction were non-functional in the sense that membrane-bound IgG-SRBC were not ingested to any significant extent by the tumor cells. However, if FcR induction occurred in the presence conA-induced rat spleen cell culture supernatants, phagocytosis of membrane-bound erythrocytes occurred. These findings suggest that for the expression of FcR which are capable of particle internalization, at least three identifiable membrane-transmitted signals are required during differentiation.

  1. Implementation of a wireless sensor network for heart rate monitoring in a senior center.

    Science.gov (United States)

    Huang, Jyh-How; Su, Tzu-Yao; Raknim, Paweeya; Lan, Kun-Chan

    2015-06-01

    Wearable sensor systems are widely used to monitor vital sign in hospitals and in recent years have also been used at home. In this article we present a system that includes a ring probe, sensor, radio, and receiver, designed for use as a long-term heart rate monitoring system in a senior center. The primary contribution of this article is successfully implementing a cheap, large-scale wireless heart rate monitoring system that is stable and comfortable to use 24 h a day. We developed new finger ring sensors for comfortable continuous wearing experience and used dynamic power adjustment on the ring so the sensor can detect pulses at different strength levels. Our system has been deployed in a senior center since May 2012, and 63 seniors have used this system in this period. During the 54-h system observation period, 10 alarms were set off. Eight of them were due to abnormal heart rate, and two of them were due to loose probes. The monitoring system runs stably with the senior center's existing WiFi network, and achieves 99.48% system availability. The managers and caregivers use our system as a reliable warning system for clinical deterioration. The results of the year-long deployment show that the wireless group heart rate monitoring system developed in this work is viable for use within a designated area.

  2. Estimation of Circadian Body Temperature Rhythm Based on Heart Rate in Healthy, Ambulatory Subjects.

    Science.gov (United States)

    Sim, Soo Young; Joo, Kwang Min; Kim, Han Byul; Jang, Seungjin; Kim, Beomoh; Hong, Seungbum; Kim, Sungwan; Park, Kwang Suk

    2017-03-01

    Core body temperature is a reliable marker for circadian rhythm. As characteristics of the circadian body temperature rhythm change during diverse health problems, such as sleep disorder and depression, body temperature monitoring is often used in clinical diagnosis and treatment. However, the use of current thermometers in circadian rhythm monitoring is impractical in daily life. As heart rate is a physiological signal relevant to thermoregulation, we investigated the feasibility of heart rate monitoring in estimating circadian body temperature rhythm. Various heart rate parameters and core body temperature were simultaneously acquired in 21 healthy, ambulatory subjects during their routine life. The performance of regression analysis and the extended Kalman filter on daily body temperature and circadian indicator (mesor, amplitude, and acrophase) estimation were evaluated. For daily body temperature estimation, mean R-R interval (RRI), mean heart rate (MHR), or normalized MHR provided a mean root mean square error of approximately 0.40 °C in both techniques. The mesor estimation regression analysis showed better performance than the extended Kalman filter. However, the extended Kalman filter, combined with RRI or MHR, provided better accuracy in terms of amplitude and acrophase estimation. We suggest that this noninvasive and convenient method for estimating the circadian body temperature rhythm could reduce discomfort during body temperature monitoring in daily life. This, in turn, could facilitate more clinical studies based on circadian body temperature rhythm.

  3. Omega-3 Polyunsaturated Fatty Acids and Heart Rate Variability

    Directory of Open Access Journals (Sweden)

    Jeppe Hagstrup Christensen

    2011-11-01

    Full Text Available Omega-3 polyunsaturated fatty acids (PUFA may modulate autonomic control of the heart because omega-3 PUFA is abundant in the brain and other nervous tissue as well as in cardiac tissue. This might partly explain why omega-3 PUFA offer some protection against sudden cardiac death (SCD. The autonomic nervous system is involved in the pathogenesis of SCD. Heart rate variability (HRV can be used as a non-invasive marker of cardiac autonomic control and a low HRV is a predictor for SCD and arrhythmic events. Studies on HRV and omega-3 PUFA have been performed in several populations such as patients with ischemic heart disease, patients with diabetes mellitus, patients with chronic renal failure, and in healthy subjects as well as in children.. The studies have demonstrated a positive association between cellular content of omega-3 PUFA and HRV and supplementation with omega-3 PUFA seems to increase HRV which could be a possible explanation for decreased risk of arrhythmic events and SCD sometimes observed after omega-3 PUFA supplementation. However, the results are not consistent and further research is needed

  4. Effect of aerobic training on heart rate recovery in patients with established heart disease; a systematic review

    NARCIS (Netherlands)

    Snoek, Johan A.; Van Berkel, Sietske; Van Meeteren, Nico; Backx, Frank J G; Daanen, Hein A M

    2013-01-01

    Background: Although a delayed decrease in heart rate during the first minute after graded exercise has been identified as a powerful predictor of overall mortality in cardiac patients, the potential to influence this risk factor by aerobic training remains to be proven. Objective: The aim was to

  5. Sleep Apnoea Detection in Single Channel ECGs by Analyzing Heart Rate Dynamics

    National Research Council Canada - National Science Library

    Zywietz, C

    2001-01-01

    .... Our analysis is based on spectral components of heart rate variability. Frequency analysis was performed using Fourier and wavelet transformation with appropriate application of the Hilbert transform...

  6. Parasympathetic neural activity accounts for the lowering of exercise heart rate at high altitude

    DEFF Research Database (Denmark)

    Boushel, Robert Christopher; Calbet, J A; Rådegran, G

    2001-01-01

    In chronic hypoxia, both heart rate (HR) and cardiac output (Q) are reduced during exercise. The role of parasympathetic neural activity in lowering HR is unresolved, and its influence on Q and oxygen transport at high altitude has never been studied.......In chronic hypoxia, both heart rate (HR) and cardiac output (Q) are reduced during exercise. The role of parasympathetic neural activity in lowering HR is unresolved, and its influence on Q and oxygen transport at high altitude has never been studied....

  7. Association between Anxiety Disorders and Heart Rate Variability in The Netherlands Study of Depression and Anxiety (NESDA)

    NARCIS (Netherlands)

    Licht, Carmilla M. M.; de Geus, Eco J. C.; van Dyck, Richard; Penninx, Brenda W. J. H.

    Objective: To determine whether patients with different types of anxiety disorder (panic disorder, social phobia, generalized anxiety disorder) have higher heart rate and lower heart rate variability compared with healthy controls in a sample that was sufficiently powered to examine the confounding

  8. Reproducibility for Heart Rate Variability Analysis during 6-Min Walk Test in Patients with Heart Failure and Agreement between Devices.

    Science.gov (United States)

    Braga, Lays Magalhães; Prado, Gustavo Faibischew; Umeda, Iracema Ioco Kikuchi; Kawauchi, Tatiana Satie; Taboada, Adriana Marques Fróes; Azevedo, Raymundo Soares; Pereira Filho, Horacio Gomes; Grupi, César José; Souza, Hayala Cristina Cavenague; Moreira, Dalmo Antônio Ribeiro; Nakagawa, Naomi Kondo

    2016-01-01

    Heart rate variability (HRV) analysis is a useful method to assess abnormal functioning in the autonomic nervous system and to predict cardiac events in patients with heart failure (HF). HRV measurements with heart rate monitors have been validated with an electrocardiograph in healthy subjects but not in patients with HF. We explored the reproducibility of HRV in two consecutive six-minute walk tests (6MW), 60-minute apart, using a heart rate monitor (PolarS810i) and a portable electrocardiograph (called Holter) in 50 HF patients (mean age 59 years, NYHA II, left ventricular ejection fraction ~35%). The reproducibility for each device was analysed using a paired t-test or the Wilcoxon signed-rank test. Additionally, we assessed the agreement between the two devices based on the HRV indices at rest, during the 6MW and during recovery using concordance correlation coefficients (CCC), 95% confidence intervals and Bland-Altman plots. The test-retest for the HRV analyses was reproducible using Holter and PolarS810i at rest but not during recovery. In the second 6MW, patients showed significant increases in rMSSD and walking distance. The PolarS810i measurements had remarkably high concordance correlation [0.86rates, a small effect in increasing differences between Holter and Polar in R-R intervals was observed. In conclusion, our study showed good reproducibility of HRV at rest in two consecutive 6MW using Holter and PolarS810i. Additionally, PolarS810i produced good agreements in short-term HRV indices based on Holter simultaneous recordings at rest, during the 6MW and recovery in HF patients.

  9. Investigation of the Effect of Occupational Noise Exposure on Blood Pressure and Heart Rate of Steel Industry Workers

    Science.gov (United States)

    Zamanian, Zahra; Rostami, Reza; Hasanzadeh, Jafar; Hashemi, Hassan

    2013-01-01

    Background and Objectives. This study aimed to investigate the effect of noise exposure on blood pressure and heart rate of steel industry workers. Materials and Methods. In the present cross-sectional study, 50 workers were selected from a steel company in Fars province, Iran, and exposed to 85, 95, and 105 dB noise levels for 5 minutes. The participants' blood pressure and heart rate were measured using Beurer BC16 pulse meter both before and after the exposure. Results. The study results showed no significant difference in blood pressure and heart rate before and after the exposure. However, the workers' systolic blood pressure had increased compared to before the exposure; of course, the difference was not statistically significant (P > 0.05). Besides, although the subjects' heart rate had reduced in comparison to before the exposure, the difference was not statistically significant (P > 0.05). Conclusion. No significant change was observed in blood pressure and heart rate after acute exposure to 85, 95, and 105 dB noise levels. PMID:23781252

  10. IgG Receptor FcγRIIB Plays a Key Role in Obesity-Induced Hypertension

    Science.gov (United States)

    Sundgren, Nathan C.; Vongpatanasin, Wanpen; Boggan, Brigid-Meghan D.; Tanigaki, Keiji; Yuhanna, Ivan S.; Chambliss, Ken L.; Mineo, Chieko; Shaul, Philip W.

    2015-01-01

    There is a well-recognized association between obesity, inflammation, and hypertension. Why obesity causes hypertension is poorly understood. We previously demonstrated using a C-reactive protein (CRP) transgenic mouse that CRP induces hypertension that is related to NO deficiency. Our prior work in cultured endothelial cells identified the Fcγ receptor IIB (FcγRIIB) as the receptor for CRP whereby it antagonizes endothelial NO synthase. Recognizing known associations between CRP and obesity and hypertension in humans, in the present study we tested the hypothesis that FcγRIIB plays a role in obesity-induced hypertension in mice. Using radiotelemetry, we first demonstrated that the hypertension observed in transgenic mouse-CRP is mediated by the receptor, indicating that FcγRIIB is capable of modifying blood pressure. We then discovered in a model of diet-induced obesity yielding equal adiposity in all study groups that whereas FcγRIIB+/+ mice developed obesity-induced hypertension, FcγRIIB−/− mice were fully protected. Levels of CRP, the related pentraxin serum amyloid P component which is the CRP-equivalent in mice, and total IgG were unaltered by diet-induced obesity; FcγRIIB expression in endothelium was also unchanged. However, whereas IgG isolated from chow-fed mice had no effect, IgG from high-fat diet–fed mice inhibited endothelial NO synthase in cultured endothelial cells, and this was an FcγRIIB-dependent process. Thus, we have identified a novel role for FcγRIIB in the pathogenesis of obesity-induced hypertension, independent of processes regulating adiposity, and it may entail an IgG-induced attenuation of endothelial NO synthase function. Approaches targeting FcγRIIB may potentially offer new means to treat hypertension in obese individuals. PMID:25368023

  11. Variation of heart transplant rates in the United States during holidays.

    Science.gov (United States)

    Grodin, Justin L; Ayers, Colby R; Thibodeau, Jennifer T; Mishkin, Joseph D; Mammen, Pradeep P A; Markham, David W; Drazner, Mark H; Patel, Parag C

    2014-08-01

    Some cardiac transplant programs may upgrade listed patients to United Network for Organ Sharing (UNOS) 1A-status during the holidays. Whether more transplants actually occur during holidays is unknown. We assessed rates of single-organ heart transplantation from 2001 to 2010 for recipients age ≥18 yr using the UNOS database. Patients were stratified by transplantation during holiday (±3 d, n = 2375) and non-holiday periods (n = 16 112). Holidays included Easter/Spring break, Memorial Day, July 4th, Labor Day, Thanksgiving, and Christmas/New Years (winter holidays). Secondary analysis assessing transplant rates across seasons was also completed. Donor and recipient characteristics were similar between groups. Compared with non-holidays, July 4th had higher transplant rates (5.69 vs. 5.09 transplants/d, p = 0.03) while the winter holiday had lower transplant rates (4.50 vs. 5.09 transplants/d, p < 0.01). There was a trend toward lower transplant rates for all holidays compared with non-holidays (p = 0.06). Transplant rates were significantly different across seasons with greater rates in spring and summer (p < 0.01). Heart transplant rates were higher during the July 4th and lower during the winter holidays. Although there was a higher likelihood of transplantation during the spring and summer seasons, upgrading patients to 1A status during most holidays may not improve their chances for transplantation. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  12. Hyperthyroidism is characterized by both increased sympathetic and decreased vagal modulation of heart rate: evidence from spectral analysis of heart rate variability.

    Science.gov (United States)

    Chen, Jin-Long; Chiu, Hung-Wen; Tseng, Yin-Jiun; Chu, Woei-Chyn

    2006-06-01

    The clinical manifestations of hyperthyroidism resemble those of the hyperadrenergic state. This study was designed to evaluate the impact of hyperthyroidism on the autonomic nervous system (ANS) and to investigate the relationship between serum thyroid hormone concentrations and parameters of spectral heart rate variability (HRV) analysis in hyperthyroidism. Thirty-two hyperthyroid Graves' disease patients (mean age 31 years) and 32 sex-, age-, and body mass index (BMI)-matched normal control subjects were recruited to receive one-channel electrocardiogram (ECG) recording. The cardiac autonomic nervous function was evaluated by the spectral analysis of HRV, which indicates the autonomic modulation of the sinus node. The correlation coefficients between serum thyroid hormone concentrations and parameters of the spectral HRV analysis were also computed. The hyperthyroid patients revealed significant differences (P hyperthyroidism in 28 patients, all of the above parameters were restored to levels comparable to those of the controls. In addition, serum thyroid hormone concentrations showed significant correlations with spectral HRV parameters. Hyperthyroidism is in a sympathovagal imbalanced state, characterized by both increased sympathetic and decreased vagal modulation of the heart rate. These autonomic dysfunctions can be detected simultaneously by spectral analysis of HRV, and the spectral HRV parameters could reflect the disease severity in hyperthyroid patients.

  13. Anti-influenza Hyperimmune Immunoglobulin Enhances Fc-functional Antibody Immunity during Human Influenza Infection.

    Science.gov (United States)

    Vanderven, Hillary A; Wragg, Kathleen; Ana-Sosa-Batiz, Fernanda; Kristensen, Anne B; Jegaskanda, Sinthujan; Wheatley, Adam K; Wentworth, Deborah; Wines, Bruce D; Hogarth, P Mark; Rockman, Steve; Kent, Stephen J

    2018-05-31

    New treatments for severe influenza are needed. Passive transfer of influenza-specific hyperimmune pooled immunoglobulin (Flu-IVIG) boosts neutralising antibody responses to past strains in influenza-infected subjects. The effect of Flu-IVIG on antibodies with Fc-mediated functions, which may target diverse influenza strains, is unclear. We studied the capacity of Flu-IVIG, relative to standard IVIG, to bind to Fc receptors and mediate antibody-dependent cellular cytotoxicity in vitro. The effect of Flu-IVIG infusion, compared to placebo infusion, was examined in serial plasma samples from 24 subjects with confirmed influenza infection in the INSIGHT FLU005 pilot study. Flu-IVIG contains higher concentrations of Fc-functional antibodies than IVIG against a diverse range of influenza hemagglutinins. Following infusion of Flu-IVIG into influenza-infected subjects, a transient increase in Fc-functional antibodies was present for 1-3 days against infecting and non-infecting strains of influenza. Flu-IVIG contains antibodies with Fc-mediated functions against influenza virus and passive transfer of Flu-IVIG increases anti-influenza Fc-functional antibodies in the plasma of influenza-infected subjects. Enhancement of Fc-functional antibodies to a diverse range of influenza strains suggests that Flu-IVIG infusion could prove useful in the context of novel influenza virus infections, when there may be minimal or no neutralising antibodies in the Flu-IVIG preparation.

  14. The effects of occupational noise on blood pressure and heart rate of workers in an automotive parts industry.

    Science.gov (United States)

    Kalantary, Saba; Dehghani, Ali; Yekaninejad, Mir Saeed; Omidi, Leila; Rahimzadeh, Mitra

    2015-07-01

    One of the most important impacts of industrial noise is physiological and psychological effects. The increases in workers' blood pressure and heart rate were detected during and after exposure to high levels of noise. The objectives of this research were to determine whether the noise exposures have any effects on blood pressure and heart rate of workers in the automotive parts industry. This case study was done in 2011 at different units of an automotive parts manufacturing in Tehran. Sound pressure level was measured at different units of the factory with a calibrated instrument. Demographic features of workers were gathered with an appropriate questionnaire. Heart rate and blood pressure were measured twice in a day in the start time of work day (before exposure to noise) and middle shift hours (during exposure to noise) in the occupational physician office. For analyzing data, chi-square, independent sample t-test, paired t-test, and analysis of covariance (ANCOVA) were used. P industrial noise may increase the heart rate of workers. Although rises in heart rate, systolic, and diastolic blood pressure of workers in the case group were observed after exposure to noise, the values of heart rate, systolic, and diastolic blood pressure were in the normal range. Further experimental investigations are needed to determine the relationships between these variables.

  15. Mercury Exposure and Heart Rate Variability: A Systematic Review

    Science.gov (United States)

    Gribble, Matthew O.; Cheng, Alan; Berger, Ronald D.; Rosman, Lori; Guallar, Eliseo

    2015-01-01

    Background Mercury affects the nervous system and has been implicated in altering heart rhythm and function. We sought to better define its role in modulating heart rate variability, a well-known marker of cardiac autonomic function. Design Systematic review. Methods We searched PubMed, Embase, TOXLINE and DART databases without language restriction. We report findings as a qualitative systematic review because heterogeneity in study design and assessment of exposures and outcomes across studies, as well as other methodological limitations of the literature, precluded a quantitative meta-analysis. Results We identified 12 studies of mercury exposure and heart rate variability in human populations (10 studies involving primarily environmental methylmercury exposure and two studies involving occupational exposure to inorganic mercury) conducted in Japan, the Faroe Islands, Canada, Korea, French Polynesia, Finland and Egypt. The association of prenatal mercury exposure with lower high-frequency band scores (thought to reflect parasympathetic activity) in several studies, in particular the inverse association of cord blood mercury levels with the coefficient of variation of the R-R intervals and with low frequency and high frequency bands at 14 years of age in the Faroe Islands birth cohort study, suggests that early mercury exposure could have a long-lasting effect on cardiac parasympathetic activity. Studies with later environmental exposures to mercury in children or in adults were heterogeneous and did not show consistent associations. Conclusions The evidence was too limited to draw firm causal inferences. Additional research is needed to elucidate the effects of mercury on cardiac autonomic function, particularly as early-life exposures might have lasting impacts on cardiac parasympathetic function. PMID:26231507

  16. Fcγ receptor I alpha chain (CD64) expression in macrophages is critical for the onset of meningitis by Escherichia coli K1.

    Science.gov (United States)

    Mittal, Rahul; Sukumaran, Sunil K; Selvaraj, Suresh K; Wooster, David G; Babu, M Madan; Schreiber, Alan D; Verbeek, J Sjef; Prasadarao, Nemani V

    2010-11-18

    Neonatal meningitis due to Escherichia coli K1 is a serious illness with unchanged morbidity and mortality rates for the last few decades. The lack of a comprehensive understanding of the mechanisms involved in the development of meningitis contributes to this poor outcome. Here, we demonstrate that depletion of macrophages in newborn mice renders the animals resistant to E. coli K1 induced meningitis. The entry of E. coli K1 into macrophages requires the interaction of outer membrane protein A (OmpA) of E. coli K1 with the alpha chain of Fcγ receptor I (FcγRIa, CD64) for which IgG opsonization is not necessary. Overexpression of full-length but not C-terminal truncated FcγRIa in COS-1 cells permits E. coli K1 to enter the cells. Moreover, OmpA binding to FcγRIa prevents the recruitment of the γ-chain and induces a different pattern of tyrosine phosphorylation of macrophage proteins compared to IgG2a induced phosphorylation. Of note, FcγRIa(-/-) mice are resistant to E. coli infection due to accelerated clearance of bacteria from circulation, which in turn was the result of increased expression of CR3 on macrophages. Reintroduction of human FcγRIa in mouse FcγRIa(-/-) macrophages in vitro increased bacterial survival by suppressing the expression of CR3. Adoptive transfer of wild type macrophages into FcγRIa(-/-) mice restored susceptibility to E. coli infection. Together, these results show that the interaction of FcγRI alpha chain with OmpA plays a key role in the development of neonatal meningitis by E. coli K1.

  17. Low vagally-mediated heart rate variability and increased susceptibility to ventricular arrhythmias in rats bred for high anxiety.

    Science.gov (United States)

    Carnevali, Luca; Trombini, Mimosa; Graiani, Gallia; Madeddu, Denise; Quaini, Federico; Landgraf, Rainer; Neumann, Inga D; Nalivaiko, Eugene; Sgoifo, Andrea

    2014-04-10

    In humans, there is a documented association between anxiety disorders and cardiovascular disease. Putative underlying mechanisms may include an impairment of the autonomic nervous system control of cardiac function. The primary objective of the present study was to characterize cardiac autonomic modulation and susceptibility to arrhythmias in genetic lines of rats that differ largely in their anxiety level. To reach this goal, electrocardiographic recordings were performed in high-anxiety behavior (HAB, n=10) and low-anxiety behavior (LAB, n=10) rats at rest, during stressful stimuli and under autonomic pharmacological manipulations, and analyzed by means of time- and frequency-domain indexes of heart rate variability. During resting conditions, HAB rats displayed a reduced heart rate variability, mostly in terms of lower parasympathetic (vagal) modulation compared to LAB rats. In HAB rats, this relatively low cardiac vagal control was associated with smaller heart rate responsiveness to acute stressors compared to LAB counterparts. In addition, beta-adrenergic pharmacological stimulation induced a larger incidence of ventricular tachyarrhythmias in HABs compared to LABs. At sacrifice, a moderate increase in heart-body weight ratio was observed in HAB rats. We conclude that high levels of anxiety-related behavior in rats are associated with signs of i) impaired autonomic modulation of heart rate (low vagally-mediated heart rate variability), ii) poor adaptive heart rate responsiveness to stressful stimuli, iii) increased arrhythmia susceptibility, and iv) cardiac hypertrophy. These results highlight the utility of the HAB/LAB model for investigating the mechanistic basis of the comorbidity between anxiety disorders and cardiovascular disease. Copyright © 2014 Elsevier Inc. All rights reserved.

  18. Accuracy of a Wrist-Worn Wearable Device for Monitoring Heart Rates in Hospital Inpatients: A Prospective Observational Study.

    Science.gov (United States)

    Kroll, Ryan R; Boyd, J Gordon; Maslove, David M

    2016-09-20

    As the sensing capabilities of wearable devices improve, there is increasing interest in their application in medical settings. Capabilities such as heart rate monitoring may be useful in hospitalized patients as a means of enhancing routine monitoring or as part of an early warning system to detect clinical deterioration. To evaluate the accuracy of heart rate monitoring by a personal fitness tracker (PFT) among hospital inpatients. We conducted a prospective observational study of 50 stable patients in the intensive care unit who each completed 24 hours of heart rate monitoring using a wrist-worn PFT. Accuracy of heart rate recordings was compared with gold standard measurements derived from continuous electrocardiographic (cECG) monitoring. The accuracy of heart rates measured by pulse oximetry (Spo2.R) was also measured as a positive control. On a per-patient basis, PFT-derived heart rate values were slightly lower than those derived from cECG monitoring (average bias of -1.14 beats per minute [bpm], with limits of agreement of 24 bpm). By comparison, Spo2.R recordings produced more accurate values (average bias of +0.15 bpm, limits of agreement of 13 bpm, P<.001 as compared with PFT). Personal fitness tracker device performance was significantly better in patients in sinus rhythm than in those who were not (average bias -0.99 bpm vs -5.02 bpm, P=.02). Personal fitness tracker-derived heart rates were slightly lower than those derived from cECG monitoring in real-world testing and not as accurate as Spo2.R-derived heart rates. Performance was worse among patients who were not in sinus rhythm. Further clinical evaluation is indicated to see if PFTs can augment early warning systems in hospitals. ClinicalTrials.gov NCT02527408; https://clinicaltrials.gov/ct2/show/NCT02527408 (Archived by WebCite at  http://www.webcitation.org/6kOFez3on).

  19. Relationship Between Exercise Heart Rate and Music\\ud Tempo Preference

    OpenAIRE

    Karageorghis, C. I; Jones, Leighton; Low, D. C

    2006-01-01

    The present study examined the predicted positive and linear relationship (Iwanaga, 1995a, 1995b) between exercise heart rate and music tempo preference. Initially, 128 undergraduate students (M age = 20.0 years, SD = 0.9) were surveyed to establish their three favorite music artists. A separate experimental group of 29 undergraduates (M age = 20.3 years, SD = 1.2) selected the music of a single artist from the three highest-rated artists from the earlier survey. They reported their\\ud prefer...

  20. Heart rate control with adrenergic blockade: Clinical outcomes in cardiovascular medicine

    Directory of Open Access Journals (Sweden)

    David Feldman

    2010-05-01

    Full Text Available David Feldman1, Terry S Elton2, Doron M Menachemi3, Randy K Wexler41Heart Failure/Transplant and VAD Programs, Minneapolis Heart Institute, Minneapolis, Minnesota, USA; 2Division of Pharmacology, College of Pharmacology, The Ohio State University, Columbus, Ohio, USA; 3Heart Failure Services, Edith Wolfson Medical Center, The Heart Institute, Sakler School of Medicine, Tel-Aviv University, Holon, Israel; 4Department of Clinical Family Medicine, The Ohio State University, Columbus, Ohio, USAAbstract: The sympathetic nervous system is involved in regulating various cardiovascular parameters including heart rate (HR and HR variability. Aberrant sympathetic nervous system expression may result in elevated HR or decreased HR variability, and both are independent risk factors for development of cardiovascular disease, including heart failure, myocardial infarction, and hypertension. Epidemiologic studies have established that impaired HR control is linked to increased cardiovascular morbidity and mortality. One successful way of decreasing HR and cardiovascular mortality has been by utilizing β-blockers, because their ability to alter cell signaling at the receptor level has been shown to mitigate the pathogenic effects of sympathetic nervous system hyperactivation. Numerous clinical studies have demonstrated that β-blocker-mediated HR control improvements are associated with decreased mortality in postinfarct and heart failure patients. Although improved HR control benefits have yet to be established in hypertension, both traditional and vasodilating β-blockers exert positive HR control effects in this patient population. However, differences exist between traditional and vasodilating β-blockers; the latter reduce peripheral vascular resistance and exert neutral or positive effects on important metabolic parameters. Clinical evidence suggests that attainment of HR control is an important treatment objective for patients with cardiovascular