WorldWideScience

Sample records for heart great vessels

  1. CT of the heart and great vessels

    International Nuclear Information System (INIS)

    Masuda, Yoshiaki; Inagaki, Yoshiaki

    1982-01-01

    Diseases of the heart and great vessels were diagnosed by CT through comparison of the pictures with that of control. Indications for CT included pericardiac diseases such as pericardial effusion, pericardiac cyst, pericardiac defect, pericardiac fat pad, and dilated or hypertrophic ventriculus. Of coronary artery diseases, myocardial infarction is the best indication for CT; and coronary artery calcification and coronary artery bypass graft for checking up the patency were also indications for this method. CT was useful for diagnosis of valvular diseases, especially mitral valve diseases, congenital heart diseases with structural abnormalities, abnormalities of the aorta and great veins, and of the pulmonary arteries and veins, and for follow-up of pulmonary congestion. (Ueda, J.)

  2. Magnetic resonance imaging of the heart and great vessels

    International Nuclear Information System (INIS)

    Naitoh, Hiroaki; Nishimura, Tsunehiko; Takamiya, Makoto; Kozuka, Takahiro.

    1985-01-01

    About sixty subjects with normal heart or various cardiovascular diseases were examined with 0.35 or 1.5 T superconductive magnetic resonance imaging (MRI) system, and ECG-gated spin-echo multislice technique was used to evaluate cardiovascular anatomy. MRI accurately demonstrated ventricular wall thinning caused by myocardial infarction and asymmetric ventricular hypertrophy owing to cardiomyopathy. Rheumatic valvular thickening, congenital cardiac malformations, aortic aneurysm and dissection were also clearly demonstrated by gated MRI without the use of any contrast media. MRI was shown to be an excellent non-invasive imaging modality for evaluation of pathoanatomy of the heart and great vessels. (author)

  3. MRI of the heart, the great vessels and the mediastinum

    International Nuclear Information System (INIS)

    Obletter, N.; Picker, D.; Stirner, H.; Schmitt, R.; Helmberger, T.

    1994-01-01

    The article surveys the most important indications for MRT of the heart, the great vessels and the mediastinum. MRT is clearly indicated with search or clarification of aneurysms of the heart wall, atrial or ventriucular septal defects with shunting or other congenital vitia in children or in the newborn, aortic aneurysms as well as connatal defects. MRT is superior to other screening methods when clarifying mediastinal neoplasms because of its multiplanar presentation and its strong quality in contrasting soft tissue. With MRT impressive dynamic studies can be obtained through cine modes and gradient echo sequences, which are very successfully used for aortic and mitral valve stenoses, for aneurysms of the heart wall, for aortic aneurysms and atrial and septal shunts. (orig./MG) [de

  4. Five cases of iatrogenic foreign body in the heart and/or great vessels

    International Nuclear Information System (INIS)

    Uda, Mitsunobu; Sawada, Satoshi; Oshima, Taichi; Kato, Tsutomu; Harima, Keizo; Tanaka, Yoshimasa

    1988-01-01

    5 cases of iatrogenic foreign body in the heart and/or great vessels were reported. We retrieved these foreign bodies (broken catheters) percutaneously by interventional radiologic technique. We detected foreign bodies by chest X-ray film, echogram and DSA. Echogram was useful in the case of radiopague foreign bodies. DSA revealed foreign bodies more clearly than chest X-ray films. We used multipurpose grasping forceps and loop snare combined with pigtail catheter to retrieve. We could retrieve foreign bodies percutaneously in all cases. (author)

  5. The heart and great vessels

    International Nuclear Information System (INIS)

    Condon, V.

    1985-01-01

    Heart disease is the fifth most common cause of death in infants and children (preceded by anoxic and hypoxic conditions, gross congenital malformations, accidental death, and immaturity). Of all the cardiac lesions, congenital heart disease (CHD) makes up the gross majority, accounting for approximately 90% of all cardiac deaths. Approximately two-thirds of all infants who die from CHD do so within the first year of life; of these, approximately one-third die within the first month. The most common cause of death in the first month is hypoplastic left heart syndrome and lesions associated with it, i.e., aortic atresia/critical aortic stenosis and mitral atresia/critical mitral stenosis. Severe coarctation of the aorta (coarctation syndrome) and transposition of the great arteries are the other most important causes of death in this age group. CHD occurs as a familial condition in approximately 1-4% of cases; ventricular septal defects, patent ductus arteriosus, and atrial septal defect are particularly common forms. Parental age plays an important role, with a significantly increased risk of CHD in infants of mothers over 39 years of age. Patent ductus arteriosus is more prevalent in firstborn children, particularly those born prematurely to young mothers. Environmental factors, such as exposure to teratogenic agents, have also been shown to increase the incidence of CHD. Children with various syndromes also have increased incidence of CHD. Down syndrome is a classic example, as are other trisomies

  6. Anatomically corrected transposition of great vessels

    International Nuclear Information System (INIS)

    Ivanitskij, A.V.; Sarkisova, T.N.

    1989-01-01

    The paper is concerned with the description of rare congenital heart disease: anatomically corrected malposition of major vessels in a 9-mos 24 day old girl. The diagnosis of this disease was shown on the results of angiocardiography, concomitant congenital heart diseases were descibed. This abnormality is characterized by common atrioventricular and ventriculovascular joints and inversion position of the major vessels, it is always attended by congenital heart diseases. Surgical intervention is aimed at the elimination of concomitant heart dieseases

  7. Standard heart and vessel size on plain films of normal children

    International Nuclear Information System (INIS)

    Stoever, B.

    1986-01-01

    Standards of heart size, i.e. heart diameters and heart volume of normal children aged 4-15 years were obtained. In all cases requiring exact heart size determination, heart volume calculation is mandatory in children as well as in adults. Statistical work to date has provided precise calculation of heart volume plain films in the upright position. Additional plain films in prone position are unnecessary because no evident orthostatic influence on heart volume in children can be found. Percentiles of normal heart volume related to body weight representing the best correlation to the individual data are given as well as percentiles related to age. Furthermore ratios of normal vessel size to the height of the 8sup(th) thoracic vertebral body, measured on the same plain film, are given. In addition the ratio of upper to lower lung vessel size is calculated. These ratios are useful criteria in estimating normal vessel size and also in cases with increased pulmonary venous pressure. (orig.) [de

  8. 46 CFR 180.206 - Survival craft-vessels operating on Great Lakes routes.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Survival craft-vessels operating on Great Lakes routes... Craft § 180.206 Survival craft—vessels operating on Great Lakes routes. (a) Except as allowed by... with the survival craft required by § 180.205 (a) through (e), as appropriate. (b) Each vessel...

  9. Imaging of pediatric great vessel stents : Computed tomography or magnetic resonance imaging?

    NARCIS (Netherlands)

    den Harder, A M; Suchá, D; van Hamersvelt, R W; Budde, R P J; de Jong, P A; Schilham, A M R; Bos, C; Breur, J M P J; Leiner, T

    2017-01-01

    BACKGROUND: Complications might occur after great vessel stent implantation in children. Therefore follow-up using imaging is warranted. PURPOSE: To determine the optimal imaging modality for the assessment of stents used to treat great vessel obstructions in children. MATERIAL AND METHODS: Five

  10. Four-dimensional (4D) flow of the whole heart and great vessels using real-time respiratory self-gating

    DEFF Research Database (Denmark)

    Uribe, Sergio; Beerbaum, Philipp; Sørensen, Thomas Sangild

    2009-01-01

    Four-dimensional (4D) flow imaging has been used to study flow patterns and pathophysiology, usually focused on specific thoracic vessels and cardiac chambers. Whole-heart 4D flow at high measurement accuracy covering the entire thoracic cardiovascular system would be desirable to simplify...... and improve hemodynamic assessment. This has been a challenge because compensation of respiratory motion is difficult to achieve, but it is paramount to limit artifacts and improve accuracy. In this work we propose a self-gating technique for respiratory motion-compensation integrated into a whole-heart 4D...... flow acquisition that overcomes these challenges. Flow components are measured in all three directions for each pixel over the complete cardiac cycle, and 1D volume projections are obtained at certain time intervals for respiratory gating in real time during the acquisition. The technique was tested...

  11. 46 CFR 117.206 - Survival craft-vessels operating on Great Lakes routes.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Survival craft-vessels operating on Great Lakes routes... PASSENGERS LIFESAVING EQUIPMENT AND ARRANGEMENTS Number and Type of Survival Craft § 117.206 Survival craft... vessel certificated to operate on a Great Lakes route must be provided with the survival craft required...

  12. Cardiac and great vessel injuries after chest trauma: our 10-year experience.

    Science.gov (United States)

    Onan, Burak; Demirhan, Recep; Öz, Kürşad; Onan, Ismihan Selen

    2011-09-01

    Cardiovascular injuries after trauma present with high mortality. The aim of the study was to present our experience in cardiac and great vessel injuries after chest trauma. During the 10-year period, 104 patients with cardiac (n=94) and great vessel (n=10) injuries presented to our hospital. The demographic data, mechanism of injury, location of injury, other associated injuries, timing of surgical intervention, surgical approach, and clinical outcome were reviewed. Eighty-eight (84.6%) males presented after chest trauma. The mean age of the patients was 32.5±8.2 years (range: 12-76). Penetrating injuries (62.5%) were the most common cause of trauma. Computed tomography was performed in most cases and echocardiography was used in some stable cases. Cardiac injuries mostly included the right ventricle (58.5%). Great vessel injuries involved the subclavian vein in 6, innominate vein in 1, vena cava in 1, and descending aorta in 2 patients. Early operations after admission to the emergency were performed in 75.9% of the patients. Thoracotomy was performed in 89.5% of the patients. Operative mortality was significantly high in penetrating injuries (p=0.01). Clinicians should suspect cardiac and great vessel trauma in every patient presenting to the emergency unit after chest trauma. Computed tomography and echocardiography are beneficial in the management of chest trauma. Operative timing depends on hemodynamic status, and a multidisciplinary team approach improves the patient's prognosis.

  13. Magnetic resonance imaging of the heart and great vessels

    International Nuclear Information System (INIS)

    Aviram, G.; Fishman, J.E.

    2004-01-01

    In recent years, there has been increasing interest in the potential of cardiac magnetic resonance imaging (MRI) to perform a 'one-stop' global cardiac MRI examination in as little as 1 hour. This possibility is enhanced by advances in MR hardware, particularly gradient field strength and specialized coils, as well as software advances, including the availability of a wide array of new fast cardiac-triggered MR pulse sequences and improvements in MR signal use, electrocardiogram (ECG) triggering and post-processing software. MRI is an evolving technology. Currently, cardiac MRI examination provides more than just high-quality information on cardiac chamber morphological anatomy. Cardiac function including ejection fraction can also be determined by fast cine MRI studies. Velocity-encoded techniques permit measurements of blood flow, which are useful for quantifying the function of both ventricles and the severity of valvular lesions. Contrast-enhanced myocardial perfusion and functional studies with pharmaceutical stress may help determine myocardial tissue viability and offer an alternative to nuclear cardiology and stress echocardiography. Coronary MR angiography is also in progress. Nevertheless, some of these new applications have not yet achieved full maturity. Cardiac MRI already has many proven clinical indications in the study of acquired heart disease, congenital heart disease, the quantification of cardiac function, and vascular disease of the thoracic aorta and pulmonary arteries. The aim of this review is to present the main applications of currently available cardiac MR technology with a brief look into recent developments that are still not widely available for daily clinical use. (author)

  14. Embolization of Collateral Vessels Using Mechanically Detachable Coils in Young Children with Congenital Heart Disease

    International Nuclear Information System (INIS)

    Sato, Y.; Ogino, H.; Hara, M.; Satake, M.; Oshima, H.; Banno, T.; Mizuno, K.; Mishima, A.; Shibamoto, Y.

    2003-01-01

    Our objective was to evaluate the usefulness of embolizing collateral vessels using mechanically detachable coils (MDCs) in children aged 3 years or younger with congenital heart disease. The subjects were 8 children with congenital heart disease featuring collateral vessels (age 18 days-3 years): 3 with a single ventricle, 2 with the tetralogy of Fallot, 2 with pulmonary atresia, and 1 with a ventricular septal defect. The embolized vessels were the major aortopulmonary collateral artery (MAPCA) in 5 patients, the persistent left superior vena cava in 2, and the coronary arteriovenous fistula in 1. A 4 or a 5 F catheter was used as the guiding device, and embolization was performed using MDCs and other conventional coils introduced through the microcatheter. One patient had growth of new MAPCAs after embolization, and these MAPCAs were also embolized with MDCs. Thus, a total of 9 embolization procedures were performed in 8 patients. Complete occlusion of the collateral vessels was achieved in 8 of 9 procedures (89%). Seven of 8 patients (88%) had uneventful courses after embolization, and MDC procedures appeared to play important roles in avoiding coil migration and achievement of safe coil embolization. One patient who underwent MAPCA embolization showed no improvement in heart function and died 2 months and 19 days later. Embolization of collateral vessels using MDCs in young children with congenital heart disease can be an effective procedure and a valuable adjunct to surgical management

  15. Three-dimensional MR imaging of congenital heart disease

    International Nuclear Information System (INIS)

    Laschinger, J.C.; Vannier, M.W.; Knapp, R.H.; Gutierrez, F.R.; Cox, J.L.

    1987-01-01

    Contiguous 5-mm thick ECG-gated MR images of the thorax were edited using surface reconstruction techniques to produce three-dimensional (3D) images of the heart and great vessels in four healthy individuals and 25 patients with congenital heart disease (aged 3 months-30 years). Anomalies studied include atrial and ventricular septal defects, aortic coarctation, AV canal defects, double outlet ventricles, hypoplastic left heart syndrome, and a wide spectrum of patients with tetralogy of Fallot. The results were correlated with echocardiographic and cineradiographic studies, and with surgical findings or pathologic specimens. Three-dimensional reconstructions accurately localized the dimensions and locations of all cardiac and great vessel anomalies and often displayed anatomic findings not diagnosed or visualized with other forms of diagnostic imaging

  16. Imaging of pediatric great vessel stents: Computed tomography or magnetic resonance imaging?

    Directory of Open Access Journals (Sweden)

    A M den Harder

    Full Text Available Complications might occur after great vessel stent implantation in children. Therefore follow-up using imaging is warranted.To determine the optimal imaging modality for the assessment of stents used to treat great vessel obstructions in children.Five different large vessel stents were evaluated in an in-vitro setting. All stents were expanded to the maximal vendor recommended diameter (20mm; n = 4 or 10mm; n = 1, placed in an anthropomorphic chest phantom and imaged with a 256-slice CT-scanner. MRI images were acquired at 1.5T using a multi-slice T2-weighted turbo spin echo, an RF-spoiled three-dimensional T1-weighted Fast Field Echo and a balanced turbo field echo 3D sequence. Two blinded observers assessed stent lumen visibility (measured diameter/true diameter *100% in the center and at the outlets of the stent. Reproducibility of diameter measurements was evaluated using the intraclass correlation coefficient for reliability and 95% limits of agreement for agreement analysis.Median stent lumen visibility was 88 (IQR 86-90% with CT for all stents at both the center and outlets. With MRI, the T2-weighted turbo spin echo sequence was preferred which resulted in 82 (78-84% stent lumen visibility. Interobserver reliability and agreement was good for both CT (ICC 0.997, mean difference -0.51 [-1.07-0.05] mm and MRI measurements (ICC 0.951, mean difference -0.05 [-2.52 --2.41] mm.Good in-stent lumen visibility was achievable in this in-vitro study with both CT and MRI in different great vessel stents. Overall reliability was good with clinical acceptable limits of agreement for both CT and MRI. However, common conditions such as in-stent stenosis and associated aneurysms were not tested in this in-vitro study, limiting the value of the in-vitro study.

  17. Imaging of pediatric great vessel stents: Computed tomography or magnetic resonance imaging?

    Science.gov (United States)

    den Harder, A M; Suchá, D; van Hamersvelt, R W; Budde, R P J; de Jong, P A; Schilham, A M R; Bos, C; Breur, J M P J; Leiner, T

    2017-01-01

    Complications might occur after great vessel stent implantation in children. Therefore follow-up using imaging is warranted. To determine the optimal imaging modality for the assessment of stents used to treat great vessel obstructions in children. Five different large vessel stents were evaluated in an in-vitro setting. All stents were expanded to the maximal vendor recommended diameter (20mm; n = 4 or 10mm; n = 1), placed in an anthropomorphic chest phantom and imaged with a 256-slice CT-scanner. MRI images were acquired at 1.5T using a multi-slice T2-weighted turbo spin echo, an RF-spoiled three-dimensional T1-weighted Fast Field Echo and a balanced turbo field echo 3D sequence. Two blinded observers assessed stent lumen visibility (measured diameter/true diameter *100%) in the center and at the outlets of the stent. Reproducibility of diameter measurements was evaluated using the intraclass correlation coefficient for reliability and 95% limits of agreement for agreement analysis. Median stent lumen visibility was 88 (IQR 86-90)% with CT for all stents at both the center and outlets. With MRI, the T2-weighted turbo spin echo sequence was preferred which resulted in 82 (78-84%) stent lumen visibility. Interobserver reliability and agreement was good for both CT (ICC 0.997, mean difference -0.51 [-1.07-0.05] mm) and MRI measurements (ICC 0.951, mean difference -0.05 [-2.52 --2.41] mm). Good in-stent lumen visibility was achievable in this in-vitro study with both CT and MRI in different great vessel stents. Overall reliability was good with clinical acceptable limits of agreement for both CT and MRI. However, common conditions such as in-stent stenosis and associated aneurysms were not tested in this in-vitro study, limiting the value of the in-vitro study.

  18. The diagnostic value of cine-MR imaging in diseases of great vessels

    International Nuclear Information System (INIS)

    Sasaki, Shigeyuki; Yoshida, Hideaki; Matsui, Yoshiro; Sakuma, Makoto; Yasuda, Keihide; Tanabe, Tatsuzo; Chouji, H.

    1990-01-01

    The diagnostic value of cine magnetic resonance imaging (cine-MRI) was evaluated in 10 patients with diseases of great vessels. The parameters necessary to decide the appropriate treatment, such as presence and extension of intimal flap, DeBakey type classification, identification of the entry, differentiation between true and false lumen, and between thrombosis and slow flow were demonstrated in all patients with dissecting aortic aneurysm. However, abdominal aortic branches could not be demonstrated enough by cine-MRI, therefore conventional AOG was necessary to choose the operative procedure in these cases. In patients with thoracic aortic aneurysm (TAA), cine-MRI was valuable in demonstrating both blood flow and thrombus in the lumen of aneurysm, and AOG was thought to be unnecessary in most cases. Cine-MRI is a promising new technique for the evaluation of diseases of great vessels. (author)

  19. Human heart by art.

    Science.gov (United States)

    Tamir, Abraham

    2012-11-01

    Heart is of great importance in maintaining the life of the body. Enough to stop working for a few minutes to cause death, and hence the great importance in physiology, medicine, and research. This fact was already emphasized in the Bible in the Book of Proverbs, chapter 4 verse 23: "Keep your heart with all diligence, for out of it is the wellspring of life." Art was able to demonstrate the heart from various aspects; realistically, as done by Leonardo de Vinci who demonstrated the halves of the heart and its blood vessels. Symbolically, as a source of life, the heart was demonstrated by the artist Mrs. Erlondeiel, as a caricature by Salvador Dali, as an open heart by Sawaya, etc. Finally, it should be emphasized that different demonstrations of the human heart by many artworks make this most important organ of our body (that cannot be seen from outside) more familiar and clearer to us. And this is the purpose of this article-to demonstrate the heart through a large number of artworks of different kinds.

  20. Histopathology of the great vessels in patients with pulmonary arterial hypertension in association with congenital heart disease: large pulmonary arteries matter too.

    Science.gov (United States)

    Prapa, Matina; McCarthy, Karen P; Dimopoulos, Konstantinos; Sheppard, Mary N; Krexi, Dimitra; Swan, Lorna; Wort, S John; Gatzoulis, Michael A; Ho, Siew Yen

    2013-10-03

    Pulmonary arterial hypertension (PAH) is considered primarily a disease of the distal pulmonary arteries whereas little is known on the effect of long-standing pulmonary hypertension on the larger proximal pulmonary arteries. This study aims to investigate the structural changes in the great arteries of adults who developed PAH in association with congenital heart disease (CHD), with severe cases termed Eisenmenger syndrome. We performed macroscopic and light microscopy analyses on the great arteries of 10 formalin-fixed human hearts from patients with PAH/CHD and compared them to age-matched healthy controls. A detailed histology grading score was used to assess the severity of medial wall abnormalities. Severe atherosclerotic lesions were found macroscopically in the elastic pulmonary arteries of 4 PAH/CHD specimens and organised thrombi in 3; none were present in the controls. Significant medial wall abnormalities were present in the pulmonary trunk (PT), including fibrosis (80%), and atypical elastic pattern (80%). Cyst-like formations were present in less than one third of patients and were severe in a single case leading to wall rupture. The cumulative PT histology grading score was significantly higher in PAH/CHD cases compared to controls (parteries. These abnormalities are likely to affect haemodynamics and contribute to morbidity and mortality in this cohort. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  1. Radiation-induced leiomyosarcoma of the great vessels presenting as superior vena cava syndrome

    International Nuclear Information System (INIS)

    Weiss, K.S.; Zidar, B.L.; Wang, S.

    1987-01-01

    A patient with a pleomorphic intravascular leiomyosarcoma of the great vessels of the neck and mediastinum presented clinically with a superior vena cava syndrome. A latent period of 29 years elapsed between receiving orthovoltage radiation to the neck and right side of chest to treat recurrent ganglioneuroblastoma, and the appearance of a leiomyosarcoma and subsequent recurrences. The patient underwent partial resection of the tumor, received adjunct chemotherapy, and was shown to be free of disease by clinical tests and by magnetic resonance imaging (MRI) 17 months after completion of chemotherapy. The criteria for the diagnosis of radiation-induced sarcomas are reviewed in relation to the present case. The critical role of magnetic resonance imaging in both the diagnosis and continued follow-up of the patient is described. This would appear to be the first reported case of radiation-induced intravascular leiomyosarcoma of the great vessels of the neck and mediastinum presenting as a superior vena cava syndrome

  2. Radiological signs pointing to altered correlations between heart and major vessels, esophagus and trachea

    International Nuclear Information System (INIS)

    Frantsov, S.

    1993-01-01

    A number of rather frequently encountered varieties and anomalies, involving heart and major vessels, esophagus, trachea, lungs and their X-ray images, are outlined. The study rests on rich experience with X-ray diagnosis of congenital cardiovascular malformations and acquired heart defects, and considers their complexity and difficult differential diagnosis. The radiological signs and diagnostic algorithm of examination are described, followed by a discussion of the differential diagnosis. The author's experience is based on X-ray diagnosis verified during operation. 9 refs., 1 fig. (orig.)

  3. MORPHOMETRIC STUDY OF THE AREOLAR SPACE BETWEEN THE GREAT VESSELS AND THE LUMBAR SPINE

    Directory of Open Access Journals (Sweden)

    Luis Marchi

    2015-12-01

    Full Text Available Objective : This work aims to study the areolar space anterior to the lumbar spine, and also the positioning of the large vessels focusing a lateral approach. Methods :This is a morphometric study of 108 cases based on T2 weighted-MRI images in the supine position. The following measurements were performed: lumbar and segmental lordosis; anteroposterior disc diameter; space between the disc/vertebral body and the vessels; bifurcation between the abdominal aorta and the common iliac veins confluence in relation to the lumbar level. Results :The areolar space with respect to the iliac veins, and with the vena cava increased cranially (p<0.001, starting from average 0.6mm at L4-L5 and reaching 8.4mm at L2, while the abdominal aorta showed no increase or decrease pattern across the different levels (p=0.135 ranging from 1.8 to 4.6mm. The diameter of the discs increased distally (p<0.01 as well as the lordosis (p<0.001. The disc diameter was 11% larger when compared to the adjacent vertebral bodies (p<0.001 and that resulted in a smaller distance of the vessels in the disc level than in the level of the adjacent vertebral bodies (p<0.001. The aortic bifurcation was generally ahead of L4 (52% and less frequently at L3-L4 (28% and L4-L5 (18%. The confluence of the veins was usually at the L4-L5 level (38% and at L5 (37%, and less frequently at L4 (26%. Conclusions : There is an identifiable plane between the great vessels and the lumbar spine which is particularly narrow in its distal portion. It is theoretically feasible to reach this plan, handle the anterior complex disc/ALL and protect the great vessels by lateral approach, however, it is challenging.

  4. 2013 Great Lakes Vessel Tracklines

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  5. 2011 Great Lakes Vessel Tracklines

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  6. Computed tomography of the heart and great vessels: present and future

    International Nuclear Information System (INIS)

    Brundage, B.H.; Rich, S.; Spigos, D.

    1984-01-01

    Computed tomography (CT) has emerged as a new imaging method for the diagnosis and evaluation of cardiovascular disease. With CT body scanners and contrast enhancement, evaluation of aortic dissections and aneurysms, coronary bypass graft patency, cardiovascular thrombus, cardiac tumors, and pericardial disease is possible. On occasion, this technique provides clinically useful information that is not available with other imaging methods. Electrocardiographic gating retrospectively or prospectively improves the image resolution of CT scans, but a new ultrafast CT scanner with a scan time of 30 to 50 milliseconds offers the greatest promise for expanding the application of the technology for cardiovascular diagnosis. Accurate measurement of cardiac chamber volume, mass, wall motion, and wall thickening will be feasible. Ultrafast CT scanning also shows great promise for the measurement of myocardial infarct size and regional myocardial blood flow

  7. Focal and diffuse papillary muscle fibrosis and small vessel sclerosis of the heart. A clinical-pathologic study of 375 autopsies

    Energy Technology Data Exchange (ETDEWEB)

    Steer, A; Danzig, M D; Robertson, T L; Kawashima, T; Nakashima, T; Lee, K K

    1975-01-01

    A retrospective clinical-pathologic study was made of papillary muscle fibrosis and small vessel sclerosis of the heart in 375 autopsies from the ABCC-JNIH Adult Health Study sample in Hiroshima and Nagasaki. The histopathologic findings were correlated with clinical diagnoses which included hypertension, hypertensive heart disease, myocardial infarction, and diabetes mellitus. (7 tables, 5 figures) (auth)

  8. Three-dimensional surface reconstruction imaging for evaluation of congenital heart disease from ECG-triggered MR images

    International Nuclear Information System (INIS)

    Vannier, M.W.; Laschinger, J.; Knapp, R.H.; Gutierrez, F.R.; Gronnemeyer, S.A.

    1987-01-01

    Three-dimensional surface reconstruction images of the heart and great vessels were produced from contiguous sequences of electrocardiographically triggered MR images in 25 patients with congenital heart disease and in three healthy subjects. The imaging data were semiautomatically processed to separate the epicardial and endocardial surfaces and to define the outline of the enclosed blood volumes on a section by section basis. Images were obtained at 5-mm intervals in patients aged 3 months to 30 years with anomalies of the great vessels, tetralogy of Fallot, septal defects, pulmonary atresia, and other congenital heart malformations. The results were used to facilitate the surgical treatment of these patients and were compared with echocardiographic and cineradiographic studies, and with surgical findings or pathologic specimens. These surface reconstruction images were useful for communicating the results of diagnostic examinations to cardiac surgeons, for sizing and location of intracardiac defects, for imaging the pulmonary venous drainage, and for assessing regional and global function

  9. Noninvasive diagnosis of thrombus in the heart and large vessels

    International Nuclear Information System (INIS)

    Masuda, Yoshiaki; Morooka, Nobuhiro; Yoshida, Hideo; Watanabe, Shigeru; Inagaki, Yoshiaki

    1984-01-01

    The usefulness of two dimensional echocardiography (2-D echocardiography) and x-ray computed tomography (CT) for the diagnosis of thrombi in the cardiac cavity and large vessels was studied by comparing them with the findings of invasive methods. Among 56 subjects with mitral stenosis, left atrial thrombi were noted in 12 cases (16 regions) by CT and 8 cases (9 regions) by 2-D echocardiography. In 16 subjects who underwent operations, one false negative case by CT and 3 false negative and one false positive cases by 2-D echocardiography were found. In 80 subjects with myocardial infarction 2-D echocardiography, CT and left ventriculography (LVG) were performed at approximately the same time. Thrombi were detected in 10 subjects (12.5%) by 2-D echocardiography, in 15 (18.8%) by CT and in 14 (17.5%) by LVG. Although mural thrombi in abdominal aortic aneurysm were detected very easily, thin thrombi surrounding the false lumen of the dissecting aneurysm were not detected ultrasonographically. These thrombi were only detected by the enhanced CT. Our results show the usefulness of both methods for detecting thrombi in the heart and large vessels. CT can distinguish the thrombi more clearly than 2-D echocardiography, but 2-D echocardiography is performed more easily, safely and economically than CT. (author)

  10. MR imaging of congenital heart disease

    International Nuclear Information System (INIS)

    Kersting-Sommerhoff, B.A.; Diethelm, L.; Teitel, D.F.; Sommerhoff, C.P.; Higgins, C.B.

    1988-01-01

    Sensitivity and specificity of MR imaging for the evaluation of congenital heart disease was assessed in 51 patients (31 male and 20 female, aged 3-69 years), with a total of 115 congenital heart lesions. The true diagnosis was established by angiocardiography, catheterization, or surgery. Sensitivity at a specificity level of 90% was determined by means of receiver operating characteristic curves for great vessel relationships (100%), thoracic aorta anomalies (94%), atrial (91%) and ventricular (100%) septal defects, visceroatrial situs (100%), loop (100%), right ventricular outflow obstructions (95%), aortic valve (52%), mitral valve (62%), and tricuspid valve (76%). Spin-echo MR imaging is a reliable method for the noninvasive evaluation of congenital heart disease but is limited in the assessment of some valvular anomalies

  11. Fourier analysis of heart SPECT slices: from remodelation to function?

    International Nuclear Information System (INIS)

    Zigman, M.; Prpic, H.; Lokner, V.

    1994-01-01

    The aim of this study was to determine character of the spatial distribution of marked erythrocytes in heart chambers, lungs and great blood vessels in relation to function of the left and right heart. Investigation included total of 142 subjects, 28 of which were without subjective and clinical signs of heart disease as well as 56 after myocardial infarction (30 of anterior localization, 26 of inferior infarction), 35 with predominant left heart disease (aortic valve disease, dilatative myocardiopathy, etc.) and 23 with predominant right heart disease (atrial septal defect, mitral valve disease). Radionuclide ventriculography (RNV) at rest, and thorax SPECT were performed in all subjects with 740 MBq Tc-99m after in vivo erythrocyte labelling with pyrophosphate. Ultrasound investigation was performed on all the subjects with heart disease and 87 of them underwent invasive cardiac investigation. RNV analysis revealed scintigraphic data on left and right ventricle: global ejection fraction (GEF), end-systolic volume (ESV), end-diastolic volume (EDV), fast tilling rate (FFR), fast emptying rate (FER) as well as regional wall motion shortening. Reconstruction of 64x64x8 SPECT images resulted in 3x64 slices (transversal, coronal and sagittal slices). Fourier analysis of 20-32 reconstructed slices in all three dimensions gave amplitude image of the intensity distribution of marked erythrocytes in heart chambers lungs and great blood vessels as well as phase display of spatial localization of regional amplitude values. Results of joint ROC curves constructed for detection, localization and character of heart disease in all subjects revealed significant clinical information content of SPECT data. Evaluation of RI retention using amplitude images in 3D provides insight in regional changes of volume, particular for atrial and lung involvement. (author)

  12. Pediatric heart surgery

    Science.gov (United States)

    Heart surgery - pediatric; Heart surgery for children; Acquired heart disease; Heart valve surgery - children ... There are many kinds of heart defects. Some are minor, and others are more serious. Defects can occur inside the heart or in the large blood vessels ...

  13. Digital subtraction angiography (DSA) of the heart and coronary arteries

    International Nuclear Information System (INIS)

    Struyven, J.J.; Delcour, C.; Brion, J.P.; Vandenbosch, G.; Claessens, J.

    1986-01-01

    Digital subtraction angiography has potential advantages over conventional radiography. The removal of background structures makes possible to visualize chambers of the heart, great vessels and coronary arteries with a lower iodine signal than with conventional cineangiography. Digital data used for imaging can been manipulated for assessment and quantitation of the ventricular fonction and the coronary circulation

  14. Significance of MR imaging in congenital heart disease

    International Nuclear Information System (INIS)

    Mayr, H.; Globits, S.; Frank, H.; Glogar, D.; Nouhold, A.; Imhof, H.

    1989-01-01

    To determine the diagnostic impact of MR imaging in congenital heart disease, the authors used a 0.5- or 1.5-T magnet to examine 85 patients. Multisection spin-echo images were obtained in three planes. Diagnoses included atrial septal defect, trilogy and tetralogy of Fallot, ventricular septal defect, transposition (seven), single ventricle, and other complex disorders. Compared with other noninvasive techniques, MR imaging allowed a much better visualization of anatomic structures and the relationship of great vessels to shunt lesions in complex congenital heart disease. In 53 (63%) of 85 patients, MR imaging made a major contribution to establishing or modifying diagnoses

  15. Decay model for biocide treatment of unballasted vessels: application for the Laurentian Great Lakes.

    Science.gov (United States)

    Sano, Larissa L; Bartell, Steven M; Landrum, Peter F

    2005-10-01

    A biocide decay model was developed to assess the potential efficacy and environmental impacts associated with using glutaraldehyde to treat unballasted overseas vessels trading on the Laurentian Great Lakes. The results of Monte Carlo simulations indicate that effective glutaraldehyde concentrations can be maintained for the duration of a vessel's oceanic transit (approximately 9-12 days): During this transit, glutaraldehyde concentrations were predicted to decrease by approximately 10% from initial treatment levels (e.g., 500 mgL(-1)). In terms of environmental impacts, mean glutaraldehyde concentrations released at Duluth-Superior Harbor, MN were predicted to be 100-fold lower than initial treatment concentrations, and ranged from 3.2 mgL(-1) (2 SD: 2.74) in April to 0.7 mgL(-1) (2 SD: 1.28) in August. Sensitivity analyses indicated that the re-ballasting dilution factor was the major variable governing final glutaraldehyde concentrations; however, lake surface temperatures became increasingly important during the warmer summer months.

  16. Imaging features of primary Sarcomas of the great vessels in CT, MRI and PET/CT: a single-center experience

    International Nuclear Information System (INIS)

    Falck, Christian von; Meyer, Bernhard; Fegbeutel, Christine; Länger, Florian; Bengel, Frank; Wacker, Frank; Rodt, Thomas

    2013-01-01

    To investigate the imaging features of primary sarcomas of the great vessels in CT, MRI and 18 F-FDG PET/CT. Thirteen patients with a primary sarcoma of the great vessels were retrospectively evaluated. All available images studies including F-18 FDG PET(/CT) (n = 4), MDCT (n = 12) and MRI (n = 6) were evaluated and indicative image features of this rare tumor entity were identified. The median interval between the first imaging study and the final diagnosis was 11 weeks (0–12 weeks). The most frequently observed imaging findings suggestive of malignant disease in patients with sarcomas of the pulmonary arteries were a large filling defect with vascular distension, unilaterality and a lack of improvement despite effective anticoagulation. In patients with aortic sarcomas we most frequently observed a pedunculated appearance and an atypical location of the filling defect. The F-18 FDG PET(/CT) examinations demonstrated an unequivocal hypermetabolism of the lesion in all cases (4/4). MRI proved lesion vascularization in 5/6 cases. Intravascular unilateral or atypically located filling defects of the great vessels with vascular distension, a pedunculated shape and lack of improvement despite effective anticoagulation are suspicious for primary sarcoma on MDCT or MRI. MR perfusion techniques can add information on the nature of the lesion but the findings may be subtle and equivocal. F-18 FDG PET/CT may have a potential role in these patients and may be considered as part of the imaging workup

  17. Impact of Plasmapheresis on the Time Course of Changes in Cytokines After Operations on the Heart and Great Vessels

    Directory of Open Access Journals (Sweden)

    A. A. Yeremenko

    2005-01-01

    Full Text Available Objective. To assess the impact of plasmapheresis on the time course of changes in pro- and anti-inflammatory interleukins and the results of treatment in patients after complicated operations on the heart and great vessels.Material and methods. 44 patients were examined. In 33 patients, the intra- and postoperative period was complicated by a prolonged extracorporeal circulation (EC, massive blood loss, acute hemolysis, the development of disseminated intravascular coagulation. The above complications gave grounds to perform plasmapheresis (PA in different postoperative periods. The patients were equally divided into 4 groups (each containing 11 patients: 1 patients with multiple organ dysfunction (MOD, in whom PA was conducted within 2—6 hours after surgery; 2 those without MOD, in whom PA was also performed within 2—6 hours after surgery; 3 those with MOD in whom PA was made 16-20 hours after surgery; 4 a control group (receiving no PA, the early postoperative period was normal. Interleukins (IL 6, 8, and 10 and the oxygenation index (OI after surgery and in the first 24 postoperative hours, the duration of EC, the volume of blood loss, and a postoperative clinical period were studied.Results. The duration of EC was highest in Group 1 patients and 37 and 130% greater in Groups 2 and 3, respectively. The elevated levels of IL-6 were noted in all the patients. In the early post-PA periods, the content of IL-6 was decreased by 30% in Groups 1 and 2 patients. In Group 3, the level of IL-6 remained unchanged within the first 24 hours. The postoperative concentration of IL-8 was increased in all the patients. There were no changes in the content of IL-8 after surgery and within the first 12 hours. In Group 3 patients, the level of IL-8 within the first 24 hours was 5 times higher than that observed just after surgery. In patients with developed MOD, a correlation was found between IL-8 and OI postoperatively and within the first 24 hours after

  18. Functional radioanatomy of the heart

    International Nuclear Information System (INIS)

    Tikhonov, K.B.

    1990-01-01

    Extensive data on radioanatomy of the heart and main vessels as applied to standard projections are presented. Anatomic structure evolution during heart cycle is described. A current trend towards complex examination of the heart and minor circulation vessels is illustrated, including digital roentgenography, digital subtraction angiography, nmr imaging, computerized tomography, radioisotope examination of the heart and positron emission tomography. Data testifying to essential effect of resperation phase and patient's placement on X-ray picture of the heart and blood flow in the lungs. 291 refs.; 131 figs

  19. Impact of Chronic Rheumatic Valve Diseases on Large Vessels.

    Science.gov (United States)

    Altunbas, Gokhan; Yuce, Murat; Ozer, Hasan O; Davutoglu, Vedat; Ercan, Suleyman; Kizilkan, Nese; Bilici, Muhammet

    2016-01-01

    BACKGROUND AND AIM OF STUDY: Rheumatic valvular heart disease, which remains a common health problem in developing countries, has numerous consequences on the heart chambers and circulation. The study aim was to investigate the effects of chronic rheumatic valve disease on the diameters of the descending aorta (DA) and inferior vena cava (IVC). METHODS: A total of 88 patients with echocardiographically documented rheumatic valvular heart disease and 112 healthy controls were enrolled into the study. All patients underwent detailed echocardiographic examinations, while their height and body weight were recorded and adjusted to their body surface area. RESULTS: The most common involvement was mitral valve disease, followed by aortic valve disease and tricuspid valve disease. The mean diameter of the DA (indexed to BSA) was 1.79 ± 0.49 cm for patients and 1.53 ± 0.41 for controls (p Rheumatic valve disease, especially mitral stenosis, was closely related to remodeling of the great vessels.

  20. A numerical analysis on the curved bileaflet Mechanical Heart Valve (MHV) : leaflet motion and blood flow in an elastic blood vessel

    International Nuclear Information System (INIS)

    Bang, Jin Seok; Kim, Chang Nyung; Choi, Choeng Ryul

    2005-01-01

    In blood flow passing through the Mechanical Heart Valve (MHV) and elastic blood vessel, hemolysis and platelet activation causing thrombus formation can be seen owing to the shear stress in the blood. Also, fracture and deformation of leaflets can be observed depending on the shape and material properties of the leaflets which is opened and closed in a cycle. Hence, comprehensive study is needed on the hemodynamics which is associated with the motion of leaflet and elastic blood vessel in terms of fluid-structure interaction. In this paper, a numerical analysis has been performed for a three-dimensional pulsatile blood flow associated with the elastic blood vessel and curved bileaflet for multiple cycles in light of fluid-structure interaction. From this analysis fluttering phenomenon and rebound of the leaflet have been observed and recirculation and regurgitation have been found in the flow fields of the blood. Also, the pressure distribution and the radial displacement of the elastic blood vessel have been obtained. The motion of the leaflet and flow fields of the blood have shown similar tendency compared with the previous experiments carried out in other studies. The present study can contribute to the design methodology for the curved bileaflet mechanical heart valve. Furthermore, the proposed fluid-structure interaction method will be effectively used in various fields where the interaction between fluid flow and structure are involved

  1. Use of corrosion casting techniques to evaluate coronary collateral vessels and anastomoses in hearts of canine cadavers.

    Science.gov (United States)

    Noestelthaller, Arne; Probst, Alexander; Koenig, Horst E

    2005-10-01

    To study and investigate branching patterns of the canine coronary arteries and collateral circulation by use of corrosion casting techniques. 31 hearts obtained from cadavers of clinically normal dogs of various ages and breeds and of either sex. 3-dimensional reproduction of coronary arteries was achieved by postmortem injection and perfusion with casting materials into the aortic sinus via the ascending aorta. Perfused hearts were macerated and carefully irrigated; the air-dried specimens were examined macroscopically and with a magnifying headset. Collateral arteries and inter- and intra-arterial anastomoses were successfully detected in 8 corrosion cast specimens. In total, 9 coronary collateral arteries and 3 interarterial anastomoses were found. Our finding of coronary collateral arteries in canine hearts is in agreement with recent findings in coronary flow study. On the basis of our results, vasodilation treatment to improve collateral vessel remodeling in dogs with myocardial dysfunction may be warranted.

  2. Left heart catheterization

    Science.gov (United States)

    Catheterization - left heart ... to help guide the catheters up into your heart and arteries. Dye (sometimes called "contrast") will be ... in the blood vessels that lead to your heart. The catheter is then moved through the aortic ...

  3. Cyanotic Congenital Heart Defects – literature review

    Directory of Open Access Journals (Sweden)

    Vlad Drăgoi

    2017-11-01

    Full Text Available Congenital heart defects are one of the most interesting and important chapters regarding abnormal fetal growth pathology. The objective of this article is to present a literature review for the main cyanotic congenital heart defects. The ones presented in the article are: tetralogy of Fallot, transposition of the great vessels, double outlet right ventricle, truncus arteriosus, total anomalous pulmonary venous circulation and additional information regarding very rare malformations such as pentalogy of Cantrell and Uhl anomaly. An early and precise identification of congenital heart defects is an important step in an accurate follow-up of a potential problematic pregnancy. Knowing the sonographic aspect, associated pathology and the current available treatment procedures are vital for the fetal outcome and for the physician to adapt the right management in every situation that might appear during the pregnancy and in the neonatal period.

  4. The heart: Congenital disease

    International Nuclear Information System (INIS)

    Higgins, C.B.

    1987-01-01

    The most important diagnostic requirement in congenital heart disease (CHD) is definition of cardiovascular pathoanatomy. The considerable success in operative correction of even the most complex anomalies in recent years compels ever increasing precision in preoperative demonstration of these anomalies. Early experience with magnetic resonance imaging (MRI) at several institutions indicated that this modality is an effective noninvasive technique for evaluation of CHD. Indeed, MRI seems to have some advantage over other techniques, including angiography, for definitive diagnosis of congenital anomalies of the heart and great arteries and veins. The absence of ionizing radiation and contrast medium in MRI is an additional advantage; the former is particularly important for children, who, up to this time, have frequently been subjected to enormous radiation burdens from multiple cineangiograms during initial diagnosis and follow-up. This chapter describes the MRI appearance of cardiovascular anatomy im the segmental fashion proposed for analysis of complex CHD. Likewise, MRI demonstration of congenital cardiovascular lesions is organized into abnormalities situated at the four segmental cardiovascular levels: great vessels, atria, ventricles, and visceroatrial relationship. The role of MRI in evaluation of complex ventricular anomalies such as single ventricle and thoracic aortic abnormalities is specifically described

  5. Diseases of the heart and main vessels

    International Nuclear Information System (INIS)

    Kiseleva, I.P.; Ivanitskij, A.V.

    1988-01-01

    The problems of roentgenoanatomy of children and adolescent heart are considered. Various methods of roentgenological examinations in diagnosis of cardo-vascular diseases (roentgenoscopy, roentgenography, tomography, roentgenokymography) are described. A scheme of data study of roentgenolocial examinations is given. Roentgenograms of children heart with various congenital and acquired heart diseases, as well as myocarditis, pericarditis, endocardium fibroelastosis are presented

  6. Anestesia en la transposición de los grandes vasos ANESTHESIA IN THE TRANSPOSITION OF THE GREAT VESSELS

    Directory of Open Access Journals (Sweden)

    Lincoln de la Parte Pérez

    2005-03-01

    Full Text Available La transposición de los grandes vasos es una cardiopatía compleja que se acompaña de una elevada mortalidad. Se conoce que el 45 % de los pacientes fallece durante el primer mes de vida y alrededor del 90 % antes del año. Las principales causas de la muerte son la hipoxia y la insuficiencia cardíaca. El desarrollo de las especialidades que trabajan en cirugía cardiovascular pediátrica ha permitido aumentar la supervivencia de estos niños, especialmente con el uso de prostaglandinas para mantener el ductus permeable, la técnica de Raskind-Miller ( septostomía de balón y una tendencia cada vez mayor a la corrección anatómica temprana (operación de Jatene en lugar de los clásicos procedimientos paliativos y las técnicas de corrección fisiológica de Senning y Mustard . Se presenta una revisión bibliográfica sobre los factores a tener en cuenta en el manejo anestésico de estos pacientes.The transposition of the great vessels is a complex heart disease accompanied of a high mortality. It is known that 45 % of the patients die during the first month of life and at about 90 % do it before being one year old. The main causes of death are hypoxia and heart failure. The development of the specialties working in pediatric cardiovascular surgery has allowed to increase the survival of these children, specially with the use of prostaglandins to maintain the ductus permeable, the Raskind-Miller's technique (balloon septostomy, and an increasing trend towards an early anatomical correction (Jatene's operation to replace the classical palliative procedures and Senning and Mustartd's techniques of physiological correction. A bibliographic review of the factors to be taken into account in the anesthetic management of these patients is presented.

  7. Heart Disease in Women

    Science.gov (United States)

    ... United States, 1 in 4 women dies from heart disease. The most common cause of heart disease in both men and women is narrowing ... the blood vessels that supply blood to the heart itself. This is called coronary artery disease, and ...

  8. Emergency department thoracotomy for penetrating injuries of the heart and great vessels: an appraisal of 283 consecutive cases from two urban trauma centers.

    Science.gov (United States)

    Seamon, Mark J; Shiroff, Adam M; Franco, Michael; Stawicki, S Peter; Molina, Ezequiel J; Gaughan, John P; Reilly, Patrick M; Schwab, C William; Pryor, John P; Goldberg, Amy J

    2009-12-01

    Historically, patients with penetrating cardiac injuries have enjoyed the best survival after emergency department thoracotomy (EDT), but further examination of these series reveals a preponderance of cardiac stab wound (SW) survivors with only sporadic cardiac gunshot wound (GSW) survivors. Our primary study objective was to determine which patients requiring EDT for penetrating cardiac or great vessel (CGV) injury are salvageable. All patients who underwent EDT for penetrating CGV injuries in two urban, level I trauma centers during 2000 to 2007 were retrospectively reviewed. Demographics, injury (mechanism, anatomic injury), prehospital care, and physiology (signs of life [SOL], vital signs, and cardiac rhythm) were analyzed with respect to hospital survival. The study population (n = 283) comprised young (mean age, 27.1 years +/- 10.1 years) men (96.1%) injured by gunshot (GSW, 88.3%) or SWs (11.7%). Patients were compared by injury mechanism and number of CGV wounds with respect to survival (SW, 24.2%; GSW, 2.8%; p cumulative impact of penetrating injury mechanism, ED SOL, and number of CGV wounds was analyzed together, we established that those sustaining multiple CGV GSWs (regardless of ED SOL) were nearly unsalvageable. These results indicate that when multiple CGV GSWs are encountered after EDT, further resuscitative efforts may be terminated without limiting the opportunity for survival.

  9. Hemodynamic simulation of the heart using a 2D model and MR data

    DEFF Research Database (Denmark)

    Adeler, Pernille Thorup

    2002-01-01

    Computational models of the blood flow in the heart are a useful tool for studying the functioning of the heart. The purpose of this thesis is to achieve a better understanding of hemodynamics of the normal and diseased hearts through the use of a computational model and magnetic resonance (MR......) data. We present a 2D computational model of the blood flow in the left side of the heart. The work is based on Peskin and McQueen's 2D model dimensioned to data on the dog heart, which we improve and adjust using physiological knowledge and MR velocity data to achieve a model of the human heart...... by letting the apical region be inactive. In both of these cases the simulation results compare well with clinically observed data on dogs and humans. We present Peskin and McQueen's 3D model of the entire human heart and the nearby great vessels. We perform a simulation with the model, where we adjust...

  10. Earthquake-proof supporting structure in reactor vessel

    International Nuclear Information System (INIS)

    Sakurai, Akio; Sekine, Katsuhisa; Madokoro, Manabu; Katoono, Shin-ichi; Konno, Mutsuo; Suzuki, Takuro.

    1990-01-01

    Conventional earthquake-proof structure comprises a vessel vibration stopper integrated to a reactor vessel, powder for restricting the horizontal displacements, a safety vessel surrounds the outer periphery of the reactor vessel and a safety vessel vibration stopper integrated therewith, which are fixed to buildings. However, there was a problem that a great amount of stresses are generated in the base of the reactor vessel vibration stopper due to reaction of the powders which restrict thermal expansion. In order to remarkably reduce the reaction of the powers, powders are charged into a spaces formed between each of the reactor vessel vibration stopper, the safety vessel vibration stopper and the flexible member disposed between them. According to this constitution, the reactor vessel vibration stopper does not undergo a great reaction of the powers upon thermal expansion of the reactor vessel to moderate the generated stresses, maintain the strength and provide earthquake-proof supporting function. (N.H.)

  11. Contrast-enhanced time-resolved 4D MRA of congenital heart and vessel anomalies: image quality and diagnostic value compared with 3D MRA

    Energy Technology Data Exchange (ETDEWEB)

    Vogt, Florian M.; Hunold, Peter; Barkhausen, Joerg [University Hospital Schleswig-Holstein, Clinic for Radiology and Nuclear Medicine, Luebeck (Germany); Theysohn, Jens M.; Kinner, Sonja [University Hospital Essen, Department of Diagnostic and Interventional Radiology and Neuroradiology, Essen (Germany); Michna, Dariusz [Elisabeth Hospital, Department of Neonatology, Essen (Germany); Neudorf, Ulrich [University Hospital Essen, Clinic for Pediatrics III, Essen (Germany); Quick, Harald H. [University of Erlangen-Nuernberg, Institute of Medical Physics, Erlangen (Germany)

    2013-09-15

    To evaluate time-resolved interleaved stochastic trajectories (TWIST) contrast-enhanced 4D magnetic resonance angiography (MRA) and compare it with 3D FLASH MRA in patients with congenital heart and vessel anomalies. Twenty-six patients with congenital heart and vessel anomalies underwent contrast-enhanced MRA with both 3D FLASH and 4D TWIST MRA. Images were subjectively evaluated regarding total image quality, artefacts, diagnostic value and added diagnostic value of 4D dynamic imaging. Quantitative comparison included signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and vessel sharpness measurements. Three-dimensional FLASH MRA was judged to be significantly better in terms of image quality (4.0 {+-} 0.6 vs 3.4 {+-} 0.6, P < 0.05) and artefacts (3.8 {+-} 0.4 vs 3.3 {+-} 0.5, P < 0.05); no difference in diagnostic value was found (4.2 {+-} 0.4 vs 4.0 {+-} 0.4); important additional functional information was found in 21/26 patients. SNR and CNR were higher in the pulmonary trunk in 4D TWIST, but slightly higher in the systemic arteries in 3D FLASH. No difference in vessel sharpness delineation was found. Although image quality was inferior compared with 3D FLASH MRA, 4D TWIST MRA yields robust images and added diagnostic value through dynamic acquisition was found. Thus, 4D TWIST MRA is an attractive alternative to 3D FLASH MRA. (orig.)

  12. Tessier Number 30 Median Mandibular Cleft With Congenital Heart Anomalies in Qena, Egypt.

    Science.gov (United States)

    Ali, Ahmed Ali Abdelrahim

    2018-01-01

    Median cleft deformities of the lower lip and mandible are very rare congenital anomalies. Our patient had median cleft of the lower lip, mandible, and the chin with tongue duplication, ankyloglossia, and cleft strap muscles with 2 neck contracture bands. This anomaly was associated with congenital heart disease transposition of great vessels, large ventricular septal defect, and severe pulmonary stenosis. Early repair was done at 6 months to improve feeding.

  13. Indirect narration : a case study of Conrad's Heart of darkness and Fitzgerald's The Great Gatsby

    Directory of Open Access Journals (Sweden)

    Majda Šavle

    2007-12-01

    Full Text Available Joseph Conrad's narrative style bas influenced many writers, including F. Scott Fitzgerald. The objective of my study on verbs used in discourse in Conrad's Heart of Darkness and Fitzgerald's The Great Gatsby was to confirm  the speculation  that besides Conrad's innovative technique of indirect narration there were other techniques (such as careful selection of imagistic detail Fitzgerald learned from Conrad.

  14. Morphological evaluation of complex congenital heart disease by magnetic resonance imaging

    International Nuclear Information System (INIS)

    Takahashi, Osahiro

    1993-01-01

    Ninety infants and children with complex congenital heart disease were examined with magnetic resonance imaging and the accuracy of morphological diagnoses by MRI was tested by comparison to the final diagnoses primarily based on angiocardiography. The sensitivity and specificity of MRI diagnoses were generally excellent in evaluating vena caval and atrial morphology, type of AV connection, ventricular morphology, type of VA connection and great vessel morphology. Although some difficulty with evaluating the detailed anatomy of the AV valve and its suspension system and fine vascular structures, MRI could demonstrate the entire cardiac structures clearly and provide the 3-dimensional information regarding the intracardiac structures, and it was extremely valuable in morphological assessment of complex congenital heart disease. (author)

  15. Heart Age PSA (:60)

    Centers for Disease Control (CDC) Podcasts

    This 60 second public service announcement is based on the September 2015 CDC Vital Signs report. Your heart age is the age of your heart and blood vessels as a result of your risk factors for heart attack and stroke. If you smoke or have high blood pressure, your heart age will be much higher than your actual age. Learn what you can do to lower your heart age and keep it low.

  16. Pericardial and congestive heart failure diagnostic with CT-and MR-imaging

    International Nuclear Information System (INIS)

    Rienmueller, R.; Seiderer, M.; Doliva, R.; Kemkes, B.; Lissner, J.

    1986-01-01

    Angiocardiography is still considered the gold standard in the estimation of functional parameters of the heart. However because of the inferior density resolution and the draw back of superimposition of cardiac structures angiocardiography provides only limited information about non cardiac and some cardiac structures for instance: The perimyo-, endocardium, the valves, the myocardial perfusion and metabolism or coronary blood flow. The present diagnostic and prognostic validity of CT and MR in visualizing the pericardium, the left ventricular myocardium, the heart chambers and the great heart vessels in the clinical work up of patients with pericardial and congestive heart failure is demonstrated. MR is more reliable in the diagnosis of left ventricular myocardial atrophy or fibrosis than CT. Disadvantages of MR include the failure to identify endo-, myo-and pericardial calcifications. The measurable improvement in the visualization of systolic and diastolic myocardial wall thickness using MR is of marked prognostic value in the preoperative exclusion of myocardial atrophy or fibrosis in patients with pericardial constriction

  17. 46 CFR 30.10-33 - Great Lakes-TB/L.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Great Lakes-TB/L. 30.10-33 Section 30.10-33 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS GENERAL PROVISIONS Definitions § 30.10-33 Great Lakes—TB/L. Under this designation shall be included all tank vessels navigating the Great Lakes. ...

  18. Pictorial Review of Surgical Anatomy in Adult Congenital Heart Disease.

    Science.gov (United States)

    De Cecco, Carlo N; Muscogiuri, Giuseppe; Madrid Pérez, José M; Eid, Marwen; Suranyi, Pal; Lesslie, Virginia W; Bastarrika, Gorka

    2017-07-01

    The survival rate of patients with congenital heart disease (CHD) has dramatically improved over the last 2 decades because of technological and surgical advances in diagnosis and treatment, respectively. The vast majority of CHD patients are, in fact, amenable to treatment by either device closure or surgery. Considering the wide spectrum of surgical procedures and complex native and derived anatomy, continuous and detailed follow-up is of paramount importance. Cardiac magnetic resonance and cardiac computed tomography angiography are the cornerstones of diagnosis and follow-up of CHD, allowing for comprehensive noninvasive assessment of the heart, coronary tree, and intrathoracic great vessels, along with both morphological and functional evaluation. The aim of this pictorial review is to provide an overview of the most common CHDs and their related surgical procedures as familiarity with the radiological findings of grown-up congenital heart disease patients is crucial for proper diagnostic and follow-up pathways.

  19. 19 CFR 4.97 - Salvage vessels.

    Science.gov (United States)

    2010-04-01

    ... United States and Great Britain ‘concerning reciprocal rights for United States and Canada in the... meaning of this statute. (e) A Mexican vessel may engage in a salvage operation on a Mexican vessel in any territorial waters of the United States in which Mexican vessels are permitted to conduct such operations by...

  20. Patient with congenital heart malformation and infective endocarditis

    Directory of Open Access Journals (Sweden)

    Ramírez Ortiz, Zoraida

    2014-10-01

    Full Text Available We present the case of a 17 year-old-man, with no remarkable past medical history, who had a one month history of worsening functional class, fatigability and dyspnea, in addition to fever and systemic inflammatory response syndrome (SIRS; a de-novo congenital heart malformation, situs inversus type, with levocardia and a ventricular septal defect (VSD associated with transposition of great vessels were documented. During hospitalization he received several antibiotic treatments without microbiological isolation or identification of the cause of hemodynamic decompensation. An Aspergillus endocarditis with emboli to different organs was identified in the post-mortem examination.

  1. CDC Vital Signs-Heart Age

    Centers for Disease Control (CDC) Podcasts

    This podcast is based on the September 2015 CDC Vital Signs report. Your heart age is the age of your heart and blood vessels as a result of your risk factors for heart attack and stroke. If you smoke or have high blood pressure, your heart age will be much higher than your actual age. Learn what you can do to lower your heart age and keep it low.

  2. Cheboygan Vessel Base

    Data.gov (United States)

    Federal Laboratory Consortium — Cheboygan Vessel Base (CVB), located in Cheboygan, Michigan, is a field station of the USGS Great Lakes Science Center (GLSC). CVB was established by congressional...

  3. NMR blood vessel imaging method and apparatus

    International Nuclear Information System (INIS)

    Riederer, S.J.

    1988-01-01

    A high speed method of forming computed images of blood vessels based on measurements of characteristics of a body is described comprising the steps of: subjecting a predetermined body area containing blood vessels of interest to, successively, applications of a short repetition time (TR) NMR pulse sequence during the period of high blood velocity and then to corresponding applications during the period of low blood velocity for successive heart beat cycles; weighting the collected imaging data from each application of the NMR pulse sequence according to whether the data was acquired during the period of high blood velocity or a period of low blood velocity of the corresponding heart beat cycle; accumulating weighted imaging data from a plurality of NMR pulse sequences corresponding to high blood velocity periods and from a plurality of NMR pulse sequences corresponding to low blood velocity periods; subtracting the weighted imaging data corresponding to each specific phase encoding acquired during the high blood velocity periods from the weighted imaging data for the same phase encoding corresponding to low blood velocity periods in order to compute blood vessel imaging data; and forming an image of the blood vessels of interest from the blood vessel imaging data

  4. Fetal Intelligent Navigation Echocardiography (FINE): a novel method for rapid, simple, and automatic examination of the fetal heart.

    Science.gov (United States)

    Yeo, Lami; Romero, Roberto

    2013-09-01

    To describe a novel method (Fetal Intelligent Navigation Echocardiography (FINE)) for visualization of standard fetal echocardiography views from volume datasets obtained with spatiotemporal image correlation (STIC) and application of 'intelligent navigation' technology. We developed a method to: 1) demonstrate nine cardiac diagnostic planes; and 2) spontaneously navigate the anatomy surrounding each of the nine cardiac diagnostic planes (Virtual Intelligent Sonographer Assistance (VIS-Assistance®)). The method consists of marking seven anatomical structures of the fetal heart. The following echocardiography views are then automatically generated: 1) four chamber; 2) five chamber; 3) left ventricular outflow tract; 4) short-axis view of great vessels/right ventricular outflow tract; 5) three vessels and trachea; 6) abdomen/stomach; 7) ductal arch; 8) aortic arch; and 9) superior and inferior vena cava. The FINE method was tested in a separate set of 50 STIC volumes of normal hearts (18.6-37.2 weeks of gestation), and visualization rates for fetal echocardiography views using diagnostic planes and/or VIS-Assistance® were calculated. To examine the feasibility of identifying abnormal cardiac anatomy, we tested the method in four cases with proven congenital heart defects (coarctation of aorta, tetralogy of Fallot, transposition of great vessels and pulmonary atresia with intact ventricular septum). In normal cases, the FINE method was able to generate nine fetal echocardiography views using: 1) diagnostic planes in 78-100% of cases; 2) VIS-Assistance® in 98-100% of cases; and 3) a combination of diagnostic planes and/or VIS-Assistance® in 98-100% of cases. In all four abnormal cases, the FINE method demonstrated evidence of abnormal fetal cardiac anatomy. The FINE method can be used to visualize nine standard fetal echocardiography views in normal hearts by applying 'intelligent navigation' technology to STIC volume datasets. This method can simplify

  5. Effect of a novel motion correction algorithm (SSF) on the image quality of coronary CTA with intermediate heart rates: Segment-based and vessel-based analyses

    Energy Technology Data Exchange (ETDEWEB)

    Li, Qianwen, E-mail: qianwen18@126.com; Li, Pengyu, E-mail: lipyu818@gmail.com; Su, Zhuangzhi, E-mail: suzhuangzhi@xwh.ccmu.edu.cn; Yao, Xinyu, E-mail: 314985151@qq.com; Wang, Yan, E-mail: wy19851121@126.com; Wang, Chen, E-mail: fskwangchen@gmail.com; Du, Xiangying, E-mail: duxying_xw@163.com; Li, Kuncheng, E-mail: kuncheng.li@gmail.com

    2014-11-15

    Highlights: • SSF provided better image quality than single-sector and bi-sector reconstruction among the intermediate heart rates (65–75 bpm). • Evidence for the application of prospective ECG-triggered coronary CTA with SSF onto an expanded heart rate range. • Information about the inconsistent effectiveness of SSF among the segments of coronary artery. - Abstract: Purpose: To evaluate the effect of SnapShot Freeze (SSF) reconstruction at an intermediate heart-rate (HR) range (65–75 bpm) and compare this method with single-sector reconstruction and bi-sector reconstruction on segmental and vessel bases in retrospective coronary computed tomography angiography (CCTA). Materials and methods: Retrospective electrocardiogram-gated CCTA was performed on 37 consecutive patients with HR between 65 and 75 bpm using a 64-row CT scanner. Retrospective single-sector reconstruction, bi-sector reconstruction, and SSF were performed for each patient. Multi-phase single-sector reconstruction was performed to select the optimal phase. SSF and bi-sector images were also reconstructed at the optimal phase. The images were interpreted in an intent-to-diagnose fashion by two experienced readers using a 5-point scale, with 3 points as diagnostically acceptable. Image quality among the three reconstruction groups were compared on per-patient, per-vessel, and per-segment bases. Results: The average HR of the enrolled patients was 69.4 ± 2.7 bpm. A total of 111 vessels and 481 coronary segments were assessed. SSF provided significantly higher interpretability of the coronary segments than bi-sector reconstructions. The qualified and excellent rates of SSF (97.9% and 82.3%) were significantly higher than those of single-sector (92.9% and 66.3%) and bi-sector (90.9% and 64.7%) reconstructions. The image quality score (IQS) using SSF was also significantly higher than those of single-sector and bi-sector reconstructions both on per-patient and per-vessel bases. On per

  6. The reverse boomerang sign: a marker for first-trimester transposition of great arteries.

    Science.gov (United States)

    Bravo-Valenzuela, Nathalie Jeanne; Peixoto, Alberto Borges; Araujo Júnior, Edward; Da Silva Costa, Fabricio; Meagher, Simon

    2017-10-12

    To describe a new sonographic marker of transposition of great arteries (TGA) during the first-trimester screening. We reviewed six cases of TGA from 2013 to 2016 in which an antenatal diagnosis of TGA at first-trimester screening (11-13 + 6 weeks of gestation) was confirmed postnatally. We specifically assessed images obtained by scanning the fetal heart in three vessels (3V) and three-vessel with trachea (3VT) views using color Doppler. The "reverse boomerang" sign was defined as a reverse curvature of right ventricle outflow tract (RVOT) at level of the 3VT view. We described six cases of confirmed TGA, five singletons and one twin pregnancy, among which only two vessels and the reverse curvature of RVOT (reverse boomerang sign) was demonstrated in the first-trimester screening at level of 3VT view. Ventricular septal defects were observed in three cases, and double outlet right ventricle in one case. No other cardiac or extracardiac anomalies were identified. Termination of pregnancy was not performed in any case. Our series case suggests that the reverse boomerang sign may improve the early prenatal screening for TGA.

  7. Heart Age PSA (:60)

    Centers for Disease Control (CDC) Podcasts

    2015-09-01

    This 60 second public service announcement is based on the September 2015 CDC Vital Signs report. Your heart age is the age of your heart and blood vessels as a result of your risk factors for heart attack and stroke. If you smoke or have high blood pressure, your heart age will be much higher than your actual age. Learn what you can do to lower your heart age and keep it low.  Created: 9/1/2015 by National Center for Chronic Disease Prevention and Health Promotion (NCCDPHP).   Date Released: 9/1/2015.

  8. Hearts and the nuclear age

    International Nuclear Information System (INIS)

    Wynchank, S.

    1982-01-01

    There are two types of nuclear cardiological investigations, one is an evaluation of myocardial perfusion and the properties of myocardial cell membranes. Thallium ion is used. The other approach is to trace a radioactive marker into the bloodstream and to observe its motion through that part of the system usually the cardiac chambers of great vessels. A third method, using labbeled molecules which participate in myocardial metabolism is now in its infancy. Nuclear medicine in cardiological application can be most relevant and there are very few problems associated with such techniques, and the costs compare very favourably with radiotherapy costs. The function and metabolism of the heart studies will enter a new era as new techniques (e.g. tomography) and new radiopharmaceuticals (e.g. marked fatty acids) become more available

  9. CDC Vital Signs-Heart Age

    Centers for Disease Control (CDC) Podcasts

    2015-09-01

    This podcast is based on the September 2015 CDC Vital Signs report. Your heart age is the age of your heart and blood vessels as a result of your risk factors for heart attack and stroke. If you smoke or have high blood pressure, your heart age will be much higher than your actual age. Learn what you can do to lower your heart age and keep it low.  Created: 9/1/2015 by National Center for Chronic Disease Prevention and Health Promotion (NCCDPHP).   Date Released: 9/1/2015.

  10. Application of annealing for WWER vessels life extension

    International Nuclear Information System (INIS)

    Badanin, V.I.; Gorynin, I.V.; Nickolaev, V.A.; Dragunov, Y.G.; Fedorov, V.G.

    1989-01-01

    Safe operation of NPP is greatly dependent on the guarantee of reactor vessel brittle failure strength with account for the effect of radiation embrittlement of vessel material. Recovery of irradiated material properties is principally important way to extend radiation life of reactor vessel. The aim of this report is to demonstrate the efficiency of annealing for recovery of vessel material properties and extension of its service-life

  11. Congenital Heart Disease: Vascular Risk Factors and Medication

    NARCIS (Netherlands)

    H.P.M. Smedts (Dineke)

    2011-01-01

    textabstractCongenital heart disease (CHD) is among the most common congenital abnormalities and involves structural anomalies of the heart and/or related major blood vessels. Congenital heart disease arises in the fi rst trimester of pregnancy, occurring often and in many forms. The reported CHD

  12. GOSPEL TEXT IN SCIENCE FICTION NOVELETTES BY V. P. KRAPIVIN (THE CYCLE "IN THE HEART OF THE GREAT CRYSTAL"

    Directory of Open Access Journals (Sweden)

    Velikanova E. A.

    2011-11-01

    Full Text Available The article analyses evangelical motives and images in a cycle of science fiction stories In the heart of the Great Crystal by Vladislav Krapivin. The reference to the evangelical text and connection to folklore and literary elements create the modern moral maintenance of books of the writer addressed to the teenage reader.

  13. TREATMENT FOR CHRONIC HEART FAILURE IN ELDERLY SUBJECTS

    Directory of Open Access Journals (Sweden)

    A. S. Poskrebysheva

    2014-07-01

    Full Text Available The treatment of chronic heart failure (CHF in patients over 60 years of age may be a challenge to a general practitioner. The physiological features of the elderly and significant comorbidity frequently have a considerable impact on the effects of drugs and the magnitude of side effects. Reduced sinus node automatism, significant atherosclerosis of the aorta and great vessels, and renal dysfunction - all should be borne in mind when choosing a drug and its dosage regimen. The paper considers non-drug treatment modalities, as well as the specific features of use of some groups of drugs and therapy for concomitant diseases in elderly patients with CHF.

  14. Prospective Heart Tracking for Whole-heart Magnetic Resonance Angiography

    Science.gov (United States)

    Moghari, Mehdi H.; Geva, Tal; Powell, Andrew J.

    2015-01-01

    Purpose To develop a prospective respiratory-gating technique (Heart-NAV) for use with contrast-enhanced 3D inversion recovery (IR) whole-heart magnetic resonance angiography (MRA) acquisitions that directly tracks heart motion without creating image inflow artifact. Methods With Heart-NAV, 1 of the startup pulses for the whole-heart steady-state free precession MRA sequence is used to collect the centerline of k-space, and its 1-dimensional reconstruction is fed into the standard diaphragm-navigator (NAV) signal analysis process to prospectively gate and track respiratory-induced heart displacement. Ten healthy volunteers underwent non-contrast whole-heart MRA acquisitions using the conventional diaphragm-NAV and Heart-NAV with 5 and 10 mm acceptance windows in a 1.5T scanner. Five patients underwent contrast-enhanced IR whole-heart MRA using a diaphragm-NAV and Heart-NAV with a 5 mm acceptance window. Results For non-contrast whole-heart MRA with both the 5 and 10 mm acceptance windows, Heart-NAV yielded coronary artery vessel sharpness and subjective visual scores that were not significantly different than those using a conventional diaphragm-NAV. Scan time for Heart-NAV was 10% shorter (p<0.05). In patients undergoing contrast-enhanced IR whole-heart MRA, inflow artifact was seen with the diaphragm-NAV but not with Heart-NAV. Conclusion Compared to a conventional diaphragm-NAV, Heart-NAV achieves similar image quality in a slightly shorter scan time and eliminates inflow artifact. PMID:26843458

  15. The importance of conventional X-ray thorax examination for heart diagnoses

    International Nuclear Information System (INIS)

    Kuhn, H.M.

    1982-01-01

    In the case that a deseased heart changes its shape or size, typical X-ray signs are generated that can be monitored with conventional X-ray diagnostic like: thorax-overview, images, cymography, tomography. They allow a conclusion towards the pathoanatomy of the particular heart-chambers and the corresponding change in hemodynamics with respect to usual topography. The large vessels and the lungs usually offer additional X-ray signs that extend those of the heart and this way help to assure diagnoses. The usual X-ray findings at the heart, the coronary vessels and the lungs are represented comprehensively and traced back to their origins. (orig.) [de

  16. Evaluation of congenital heart disease by three-dimensional MR imaging

    International Nuclear Information System (INIS)

    Vannier, M.W.; Gutierrez, F.R.; Canter, C.E.; Yoffie, R.L.; Hildebolt, C.F.

    1988-01-01

    In an evaluation of the detectability of intra-and extracardiac morphologic defects with electrocardiographically gated magnetic resonance (MR) imaging, 100 patients were studied, including ten without and 90 with abnormalities. The abnormalities included septal defects, tetrology of Fallot, pulmonary atresia, transposition of the great vessels, and others. The patients with abnormalities were studied angiographically and with echocardiographic analyses. Two radiologists with cardiac MR imaging experience evaluated the scans in a blinded fashion, and the results were analyzed by means of receiver operating characteristic analysis. The diagnostic value of routine two-dimensional cardiac MR imaging was compared with that of three-dimensional reconstruction imaging and with the results of cardiac catheterization and echocardiography. The reported sensitivity and specificity of echocardiography in the detection of congenital heart disease is comparable to that of MR imaging. The differences in diagnostic value between various modalities for the imaging of congenital heart disease may be determined from the results of the preliminary series

  17. [Value of chest x-ray films in the diagnosis of congenital heart defects in infants].

    Science.gov (United States)

    Koczyński, A

    1982-01-01

    The respiratory distress and suspicion of the heart defects in newborns and infants is indicated by x-ray chest examinations. The right interpretation of the x-ray pictures is very important but it must be followed by other diagnostic procedures. In every child it is possible to take the linear measurements of the great vessels and arteries in parahilar lung areas as well as the heart and chest in two dimensions from x-ray plain films. The measurements let to establish the indices: cardio-thoracic (ICP), vasculo-cardiac (IVC) and sagittal one (IS), which play important role in radiological evaluation of the chest. It results from the investigated material, that the evaluation of the pulmonary vascular pattern and the indices particularly facilitate the diagnosis of heart deformities coexisting with higher blood flow in pulmonary circulation. Nevertheless the measurements and the indices play the relative role in establishing of the final opinion about the chest and should be considered together with clinical and cardiological data.

  18. Final processing vessel for radioactive waste

    International Nuclear Information System (INIS)

    Tejima, Takaya; Hiraki, Akimitsu.

    1989-01-01

    An inorganic inner layer comprising dense inorganic material such as organic polymer-impregnated concretes is formed to about 10 - 50 mm in average thickness at the inside of a metal vessel. Further, the surface of the vessel is formed as a flat surface with no or only small reinforcing protrusions. Thus, if the final processing vessel should be dropped during transportation or handling by mistake, since impact shocks do not concentrate to protrusions as usual, no local stress concentration occurs to the inorganic inner liner layer. Accordingly, the risk of rapture can be reduced greatly. Further, since impact shock resistance layer put between the metal vessel and the inorganic inner liner layer absorbs shocks, a further sufficient strength can be obtained against dropping accident. (T.M.)

  19. Myocardial scintigraphy with 201thallium for the diagnosis of coronary heart disease and heart muscle disease

    International Nuclear Information System (INIS)

    Keller, E.

    1986-01-01

    This work gives an overview of the presently used methods of diagnostic and therapy of coronary heart disease. With the use of 105 patients the viability of scintigraphical and radiological studies were compared to each other. The thallium scintigraphy thereby achieves excellent results with a sensitivity of 95% of coronary heart disease (with a pre-determined exclusion of myocardial diseases). In three cases small vessel disease was detected which could not be detected by a coronary angiogram. The correct localization of coronary stenosis with thallium scintigraphy was attained in the area of LAD at 77% and in the avea of RCA at 74% fairly reliable, whereas the determination of circumflex artery (sensitivity 29%) was rather poor. Also, the excact determination of the extent of coronary sclerosis shows that with multiple vessel diseases the sensitivity clearly decreases (1-vessel 78%, 2-vessel 38%, 3-vessel 13%), whereby the various coronary stenoses probably appear differently in scintigraphs. A better study method for the exact determination of the extent of myocardial ischemia is offered by the single photon emission computer tomography (SPECT) with the use of a rotating gamma camera. In view of the differential diagnostic for coronary diseases myocardial scintigraphy still plays a major role in myocardial diseases. In my own research pathological storage patterns could be shown in 14 such cases. (orig./MG) [de

  20. Scanning electron microscopy of the dorsal vessel of Panstrongylus megistus (Burmeister, 1835 (Hemiptera: Reduviidae

    Directory of Open Access Journals (Sweden)

    Nadir Francisca Sant'Anna Nogueira

    1991-03-01

    Full Text Available In this study we analyzed the microanatomy of the dorsal vessel of the triatomine Panstrongylus megistus. The organ is a tuble anatomically divided into an anterior aorta anad a posterior heart, connected to the body wall through 8 pairs of alary muscles. The heart is divided in 3 chambers by means of 2 pairs of cardiac valves. a pair of ostia can be observed in the lateral wall of each chamber. A bundle of nerve fibers was found outside the organ, running dorsally along its major axis. A group of longitudinal muscular fibers was found in the ventral portion of the vessel. The vessel was found to be lined both internally and externally by pericardial cells covered by a thin laminar membrane. Inseide the vessel the pericardial cells were disposed in layers and on the outside they formed clusters or rows.

  1. Immunohistochemical Distribution of Serum Proteins in Living Mouse Heart with In Vivo Cryotechnique

    International Nuclear Information System (INIS)

    Shi, Liye; Terada, Nobuo; Saitoh, Yurika; Saitoh, Sei; Ohno, Shinichi

    2011-01-01

    In vivo cryotechnique (IVCT), which immediately cryofixes target organs in situ, was used to clarify the morphological features of beating heart tissue of living mice. IVCT was performed for diastolic heart tissue under the condition of monitoring with electrocardiogram (ECG). Other mouse hearts were prepared with conventional perfusion-fixation (PF-DH) or immersion-fixation followed by dehydration (IM-DH), and quick-freezing of resected heart tissues (FQF). Immunolocalizations of albumin, immunoglobulin G1 (IgG1), intravenously injected bovine serum albumin (BSA), and connexin 43 were examined after different intervals of BSA injection. In the case of IVCT, the exact stop time of beating mouse hearts was recorded by ECG, and open blood vessels with flowing erythrocytes were observed with less artificial tissue shrinkage than with conventional preparation methods. Both albumin and BSA were well preserved in intercalated discs and t-tubules of cardiomyocytes in addition to blood vessels and interstitial matrices. IgG1 was immunolocalized in interstitial matrices of heart tissues in addition to their blood vessels. At 4 hr after BSA injection, it was immunolocalized in the intercalated discs of cardiomyocytes and lost later at 8 hr. IVCT should prove to be more useful for the morphofunctional examination of dynamically changing heart tissue than conventional preparation methods

  2. Carbon nanoparticles downregulate expression of basic fibroblast growth factor in the heart during embryogenesis

    DEFF Research Database (Denmark)

    Wierzbicki, Mateusz; Sawosz, Ewa; Grodzik, Marta

    2013-01-01

    indices of the embryos' health. However, vascularization of the heart and the density of branched vessels were significantly reduced after treatment with diamond nanoparticles and, to a lesser extent, graphite nanoparticles. Application of nanoparticles significantly downregulated gene and protein......Carbon nanoparticles, with their high biocompatibility and low toxicity, have recently been considered for biomedical applications, including antiangiogenic therapy. Critical to normal development and tumor formation, angiogenesis is the process of forming capillary blood vessels from preexisting...... vessels. In the present study, we evaluated the effects of diamond and graphite nanoparticles on the development of chicken embryos, as well as vascularization of the chorioallantoic membrane and heart at the morphological and molecular level. Nanoparticles did not affect either body/heart weight or serum...

  3. Vacuum vessel for thermonuclear device

    International Nuclear Information System (INIS)

    Kikuchi, Mitsuru; Kurita, Gen-ichi; Onozuka, Masaki; Suzuki, Masaru.

    1997-01-01

    Heat of inner walls of a vacuum vessel that receive radiation heat from plasmas by way of first walls is removed by a cooling medium flowing in channels for cooling the inner walls. Nuclear heat generation of constitutional materials of the vacuum vessel caused by fast neutrons and γ rays is removed by a cooling medium flowing in cooling channels disposed in the vacuum vessel. Since the heat from plasmas and the nuclear heat generation are removed separately, the amount of the cooling medium flowing in the channels for cooling inner walls is increased for cooling a great amount of heat from plasmas while the amount of the cooling medium flowing in the channels for cooling the inside of the vacuum vessel is reduced for cooling the small amount of nuclear heat generation. Since the amount of the cooling medium can thus be optimized, the capacity of the facilities for circulating the cooling medium can be reduced. In addition, since the channels for cooling the inner walls and the channels of cooling medium formed in the vacuum vessel are disposed to the inner walls of the vacuum vessel on the side opposite to plasmas, integrity of the channels relative to leakage of the cooling medium can be ensured. (N.H.)

  4. Vacuum vessel for thermonuclear device

    Energy Technology Data Exchange (ETDEWEB)

    Kikuchi, Mitsuru; Kurita, Gen-ichi [Japan Atomic Energy Research Inst., Tokyo (Japan); Onozuka, Masaki; Suzuki, Masaru

    1997-07-31

    Heat of inner walls of a vacuum vessel that receive radiation heat from plasmas by way of first walls is removed by a cooling medium flowing in channels for cooling the inner walls. Nuclear heat generation of constitutional materials of the vacuum vessel caused by fast neutrons and {gamma} rays is removed by a cooling medium flowing in cooling channels disposed in the vacuum vessel. Since the heat from plasmas and the nuclear heat generation are removed separately, the amount of the cooling medium flowing in the channels for cooling inner walls is increased for cooling a great amount of heat from plasmas while the amount of the cooling medium flowing in the channels for cooling the inside of the vacuum vessel is reduced for cooling the small amount of nuclear heat generation. Since the amount of the cooling medium can thus be optimized, the capacity of the facilities for circulating the cooling medium can be reduced. In addition, since the channels for cooling the inner walls and the channels of cooling medium formed in the vacuum vessel are disposed to the inner walls of the vacuum vessel on the side opposite to plasmas, integrity of the channels relative to leakage of the cooling medium can be ensured. (N.H.)

  5. Immersive volume rendering of blood vessels

    Science.gov (United States)

    Long, Gregory; Kim, Han Suk; Marsden, Alison; Bazilevs, Yuri; Schulze, Jürgen P.

    2012-03-01

    In this paper, we present a novel method of visualizing flow in blood vessels. Our approach reads unstructured tetrahedral data, resamples it, and uses slice based 3D texture volume rendering. Due to the sparse structure of blood vessels, we utilize an octree to efficiently store the resampled data by discarding empty regions of the volume. We use animation to convey time series data, wireframe surface to give structure, and utilize the StarCAVE, a 3D virtual reality environment, to add a fully immersive element to the visualization. Our tool has great value in interdisciplinary work, helping scientists collaborate with clinicians, by improving the understanding of blood flow simulations. Full immersion in the flow field allows for a more intuitive understanding of the flow phenomena, and can be a great help to medical experts for treatment planning.

  6. Evaluation of Pulmonary Perfusion Scan in Heart Disease

    Energy Technology Data Exchange (ETDEWEB)

    Lee, J T; Kim, C K; Park, C Y; Choi, B S [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1973-09-15

    Pulmonary perfusion scan with radioactive {sup 113m}In-iron hydroxide particle was performed in the 25 cases of heart disease which had been diagnosed by cardiac catheterization prior to surgery from July, 1972 to July, 1973 at the Department of Radiology and Nuclear Medicine, Yonsei Medical College. It consists of 7 mitral stenosis, 2 mitral insufficiency, 1 aortic insufficiency, 3 atrial septal defect, 5 ventricular septal defect, 2 patent ductus arteriosus, 1 transposition of great vessel and 4 Tetralogy of Fallot. Findings of pulmonary perfusion scan in relation to hemodynamic data of cardiac catheterization were examined. 1) Out of 10 cases of acquired valvular heart disease, In 6 cases of stenosis and 1 case of aortic insufficiency, radioactivity was increased at both upper lung. This finding is noted when pulmonary wedge or venous pressure was elevated above 22 mmHg and arterial systolic pressure above 33 mmHg. 2) Out of 15 cases of congenital heart disease. In almost all cases of artial septal defect and ventricular septal defect except 2 cases, radioactivity was even at both entire lung. In 2 cases of patent ductras arteriosus, radioactivity was decreased especially at the left lung. It is observed that in acyanotic congenital heart disease, radioactivity of lung is not related with pulmonary arterial pressure. In 3 cases of Tetralogy of Fallot, radioactivity was even at both entire lung and in 2 of them, extrapulmonary radioactivity of liver or kidney which depends on size of defect and volume of right to left shunt reversible, was noted.

  7. Evaluation of Pulmonary Perfusion Scan in Heart Disease

    International Nuclear Information System (INIS)

    Lee, J. T.; Kim, C. K.; Park, C. Y.; Choi, B. S.

    1973-01-01

    Pulmonary perfusion scan with radioactive 113m In-iron hydroxide particle was performed in the 25 cases of heart disease which had been diagnosed by cardiac catheterization prior to surgery from July, 1972 to July, 1973 at the Department of Radiology and Nuclear Medicine, Yonsei Medical College. It consists of 7 mitral stenosis, 2 mitral insufficiency, 1 aortic insufficiency, 3 atrial septal defect, 5 ventricular septal defect, 2 patent ductus arteriosus, 1 transposition of great vessel and 4 Tetralogy of Fallot. Findings of pulmonary perfusion scan in relation to hemodynamic data of cardiac catheterization were examined. 1) Out of 10 cases of acquired valvular heart disease, In 6 cases of stenosis and 1 case of aortic insufficiency, radioactivity was increased at both upper lung. This finding is noted when pulmonary wedge or venous pressure was elevated above 22 mmHg and arterial systolic pressure above 33 mmHg. 2) Out of 15 cases of congenital heart disease. In almost all cases of artial septal defect and ventricular septal defect except 2 cases, radioactivity was even at both entire lung. In 2 cases of patent ductras arteriosus, radioactivity was decreased especially at the left lung. It is observed that in acyanotic congenital heart disease, radioactivity of lung is not related with pulmonary arterial pressure. In 3 cases of Tetralogy of Fallot, radioactivity was even at both entire lung and in 2 of them, extrapulmonary radioactivity of liver or kidney which depends on size of defect and volume of right to left shunt reversible, was noted.

  8. Clinical usefulness of cine MRI for evaluation of left ventricular volume and diagnosis of heart and great vessel diseases

    Energy Technology Data Exchange (ETDEWEB)

    Kondo, Takeshi; Anno, Hirofumi; Uritani, Tomizo [Fujita-Gakuen Health Univ., Toyoake, Aichi (Japan); and others

    1990-01-01

    ECG-gated cine mode magnetic resonance (MR) imaging was performed in 20 patients with various heart deseases. Left ventricular volume (LVV) and left ventricular ejection fraction (LVEF) were calculated on MR images obtained in left ventricular vertical and horizontal long axis views. The findings were compared with those obtained from left ventriculography. There was a significant positive correlation between MR imaging and ventriculography for both LVV and LVEF (p<0.001). In Marfan syndrome after surgery for dissecting aneurysm of the aorta, MR imaging was capable of visualizing not only the whole aorta in a single plane but also enlargement of the aortic root. It also depicted asynergy and thinned wall of the infarcted myocardium for myocardial infarction; an enlarged left auricle, the thickened septum, and constricted outflow tract for idiopathic hypertrophic subaortic stenosis; shunt flow for ventricular septum defect; and an enlarged aortic root for aortitis syndrome. Using ventriculography as the standard, cine MR imaging was frequently false positive for the detection of mitral regurgitation. There was, however, good concordance between MR imaging and ventriculography in detecting aortic regurgitation. In addition, MR imaging was equivalent to color Doppler technique for detecting valvular regurgitation. (N.K.).

  9. Clinical usefulness of cine MRI for evaluation of left ventricular volume and diagnosis of heart and great vessel diseases

    International Nuclear Information System (INIS)

    Kondo, Takeshi; Anno, Hirofumi; Uritani, Tomizo

    1990-01-01

    ECG-gated cine mode magnetic resonance (MR) imaging was performed in 20 patients with various heart deseases. Left ventricular volume (LVV) and left ventricular ejection fraction (LVEF) were calculated on MR images obtained in left ventricular vertical and horizontal long axis views. The findings were compared with those obtained from left ventriculography. There was a significant positive correlation between MR imaging and ventriculography for both LVV and LVEF (p<0.001). In Marfan syndrome after surgery for dissecting aneurysm of the aorta, MR imaging was capable of visualizing not only the whole aorta in a single plane but also enlargement of the aortic root. It also depicted asynergy and thinned wall of the infarcted myocardium for myocardial infarction; an enlarged left auricle, the thickened septum, and constricted outflow tract for idiopathic hypertrophic subaortic stenosis; shunt flow for ventricular septum defect; and an enlarged aortic root for aortitis syndrome. Using ventriculography as the standard, cine MR imaging was frequently false positive for the detection of mitral regurgitation. There was, however, good concordance between MR imaging and ventriculography in detecting aortic regurgitation. In addition, MR imaging was equivalent to color Doppler technique for detecting valvular regurgitation. (N.K.)

  10. Adults with Congenital Heart Defects

    Science.gov (United States)

    ... Ebstein's Anomaly l-Transposition of the Great Arteries Patent Ductus Arteriosus (PDA) Pulmonary Valve Stenosis and Regurgitation ... Sodium and Salt 3 Heart Attack Symptoms in Women 4 Warning Signs of a Heart Attack 5 ...

  11. Heart regeneration.

    Science.gov (United States)

    Breckwoldt, Kaja; Weinberger, Florian; Eschenhagen, Thomas

    2016-07-01

    Regenerating an injured heart holds great promise for millions of patients suffering from heart diseases. Since the human heart has very limited regenerative capacity, this is a challenging task. Numerous strategies aiming to improve heart function have been developed. In this review we focus on approaches intending to replace damaged heart muscle by new cardiomyocytes. Different strategies for the production of cardiomyocytes from human embryonic stem cells or human induced pluripotent stem cells, by direct reprogramming and induction of cardiomyocyte proliferation are discussed regarding their therapeutic potential and respective advantages and disadvantages. Furthermore, different methods for the transplantation of pluripotent stem cell-derived cardiomyocytes are described and their clinical perspectives are discussed. This article is part of a Special Issue entitled: Cardiomyocyte Biology: Integration of Developmental and Environmental Cues in the Heart edited by Marcus Schaub and Hughes Abriel. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. On the Possible Interaction Mechanism between Collateral Vessels and Restenosis

    NARCIS (Netherlands)

    Zun, P.S.; Hoekstra, A.G.

    2015-01-01

    Several clinical studies and their meta-analysis suggest that developed collateral vessels in the heart correlate to an increased risk of in-stent restenosis. The possible physiological interaction between the collateral development and in-stent restenosis is investigated in this study. Based on

  13. Radiology trainer. Torso, internal organs and vessels. 2. ed.

    International Nuclear Information System (INIS)

    Staebler, Axel; Erlt-Wagner, Birgit

    2013-01-01

    The radiology training textbook is based on case studies of the clinical experience, including radiological imaging and differential diagnostic discussion. The scope of this volume covers the torso, internal organs and vessels. The following issues are discussed: lungs, pleura, mediastinum; heart and vascular system; upper abdomen organs; gastrointestinal tract; urogenital system.

  14. Genome-Wide Approaches to Drosophila Heart Development

    Directory of Open Access Journals (Sweden)

    Manfred Frasch

    2016-05-01

    Full Text Available The development of the dorsal vessel in Drosophila is one of the first systems in which key mechanisms regulating cardiogenesis have been defined in great detail at the genetic and molecular level. Due to evolutionary conservation, these findings have also provided major inputs into studies of cardiogenesis in vertebrates. Many of the major components that control Drosophila cardiogenesis were discovered based on candidate gene approaches and their functions were defined by employing the outstanding genetic tools and molecular techniques available in this system. More recently, approaches have been taken that aim to interrogate the entire genome in order to identify novel components and describe genomic features that are pertinent to the regulation of heart development. Apart from classical forward genetic screens, the availability of the thoroughly annotated Drosophila genome sequence made new genome-wide approaches possible, which include the generation of massive numbers of RNA interference (RNAi reagents that were used in forward genetic screens, as well as studies of the transcriptomes and proteomes of the developing heart under normal and experimentally manipulated conditions. Moreover, genome-wide chromatin immunoprecipitation experiments have been performed with the aim to define the full set of genomic binding sites of the major cardiogenic transcription factors, their relevant target genes, and a more complete picture of the regulatory network that drives cardiogenesis. This review will give an overview on these genome-wide approaches to Drosophila heart development and on computational analyses of the obtained information that ultimately aim to provide a description of this process at the systems level.

  15. Limiting Factors for External Reactor Vessel Cooling

    International Nuclear Information System (INIS)

    Cheung, F.B.

    2005-01-01

    The method of external reactor vessel cooling (ERVC) that involves flooding of the reactor cavity during a severe accident has been considered a viable means for in-vessel retention (IVR). For high-power reactors, however, there are some limiting factors that might adversely affect the feasibility of using ERVC as a means for IVR. In this paper, the key limiting factors for ERVC have been identified and critically discussed. These factors include the choking limit for steam venting (CLSV) through the bottleneck of the vessel/insulation structure, the critical heat flux (CHF) for downward-facing boiling on the vessel outer surface, and the two-phase flow instabilities in the natural circulation loop within the flooded cavity. To enhance ERVC, it is necessary to eliminate or relax these limiting factors. Accordingly, methods to enhance ERVC and thus improve margins for IVR have been proposed and demonstrated, using the APR1400 as an example. The strategy is based on using two distinctly different methods to enhance ERVC. One involves the use of an enhanced vessel/insulation design to facilitate steam venting through the bottleneck of the annular channel. The other involves the use of an appropriate vessel coating to promote downward-facing boiling. It is found that the use of an enhanced vessel/insulation design with bottleneck enlargement could greatly facilitate the process of steam venting through the bottleneck region as well as streamline the resulting two-phase motions in the annular channel. By selecting a suitable enhanced vessel/insulation design, not only the CLSV but also the CHF limits could be significantly increased. In addition, the problem associated with two-phase flow instabilities and flow-induced mechanical vibration could be minimized. It is also found that the use of vessel coatings made of microporous metallic layers could greatly facilitate downward-facing boiling on the vessel outer surface. With vessel coatings, the local CHF limits at

  16. Clinical value of 201Tl lung/heart ratio during exercise in hypertensive patients with coronary artery disease

    International Nuclear Information System (INIS)

    Ouyang Wei; He Guorong; Liu Jinhua; Huang Yuying

    2002-01-01

    Objective: The purpose of the study was to evaluate the relationship between 201 Tl lung/heart ratio during exercise and left ventricular diastolic function and its diagnostic value on severity of coronary artery disease. Methods: One hundred and two patients with documented coronary artery disease were divided into three groups, including no hypertension, hypertension without or with left ventricular hypertrophy groups. Exercise/delay 201 Tl myocardial perfusion tomography was performed on all patients included. Lung/heart ratio was defined on the anterior planar image obtained during exercise tomography. Results: The lung/heart ratios during exercise in no hypertension (0.43 +- 0.09, P 0.05). The lung/heart ratios of multi-vessel disease subgroup in no hypertension (0.46 +- 0.10 vs 0.40 +- 0.09, P 0.05). When lung/heart ratio was≥0.45, the sensitivities for predicting the presence of multi-vessel disease were 82%, 90%, 40% and specificities were 75%, 75%, 45%, respectively, in no hypertension, hypertension without and with hypertrophy groups. In no hypertension (r=0.402, P 0.05). In no hypertension (r=-0.413, P<0.01), hypertension without (r=-0.662, P<0.01) and with hypertrophy groups (r=-0.408, P<0.05), lung/heart ratios all showed a significant reverse correlation with correspondent E/A ratios. Conclusions: The exercise lung/heart ratios has a better diagnostic value for multi-vessel disease and left ventricular diastolic function abnormalities of coronary artery disease with or without hypertension, but not for multi-vessel disease in hypertension patients complicated with myocardial hypertrophy

  17. MRI of the Chest

    Medline Plus

    Full Text Available ... function of these structures (heart, valves, great vessels, etc.). top of page What are some common uses ... of the heart and its component structures (valves, etc.). assess myocardial perfusion (blood flow to the heart) ...

  18. Cardiac imaging. Direct diagnosis in radiology

    International Nuclear Information System (INIS)

    Claussen, C.D.; Miller, S.; Fenchel, M.; Kramer, U.; Riessen, R.

    2008-01-01

    Teh book covers chest radiographic findings, echocardiographic findings, PET findings, CT findings, MRI findings and invasive diagnostic procedures within the following chapters: ischemic heart diseases; heart failure; acquired valvular heart diseases, cardiomyopathy; inflammatory heart diseases, hypertension, tumors and other masses; trauma; congenital heart diseases, diseases of the great vessels; and standard views of the heart

  19. Coronary Artery Disease - Coronary Heart Disease

    Science.gov (United States)

    ... not as great as men's. Heredity (Including Race) Children of parents with heart disease are more likely to develop it themselves. African Americans have more severe high blood pressure than Caucasians and a higher risk of heart ...

  20. Understand Your Risk of Heart Attack

    Science.gov (United States)

    ... not as great as men's. Heredity (Including Race) Children of parents with heart disease are more likely to develop it themselves. African Americans have more severe high blood pressure than Caucasians and a higher risk of heart ...

  1. Construction of reactor vessel bottom of prestressed reinforced concrete

    International Nuclear Information System (INIS)

    Sitnikov, M.I.; Metel'skij, V.P.

    1980-01-01

    Methods are described for building reactor vessel bottoms of prestressed reinforced concrete during NPPs construction in Great Britain, France, Germany (F.R.) and the USA. Schematic of operations performed in succession is presented. Considered are different versions of one of the methods for concreting a space under a facing by forcing concrete through a hole in the facing. The method provides tight sticking of the facing to the reactor vessel bottom concrete

  2. Potentialities of radioisotope aniocardiography in diagnosis of acquired heart diseases

    International Nuclear Information System (INIS)

    Malov, G.A.; Mikaelyan, R.S.; Dumpe, A.N.

    1980-01-01

    On the base of the examination of 40 patients with acquired heart diseases and 5 people without heart diseases for control determined are the most charactreristic signs of the acquired heart disease of visual observation on RPP transit (albumin of human serum labelled by sup(99m)Tc) through the heart cavities and magistral vessels. It is shown that there is a close connection between central and intracardial hemodynamics which permjts to judge on the cardiac output on the base of mean circulation time (MCT). Radioisotopic angiocardiography permits to find redistribution of lung blood flow in patients with acquired heart diseases, which can serve as indirect index of long hypertension

  3. Dynamics of fisheries, and the flexibility of vessel activity in Denmark between 1989 and 2001

    DEFF Research Database (Denmark)

    Ulrich, Clara; Andersen, Bo Sølgaard

    2004-01-01

    the activity of individual fishing vessels between 1989 and 2001. Initially, a typology of fisheries (classification of fishing trips) and vessel groups (classification of fishing vessels) was established through multivariate analyses of catch and effort data for 1999. In all, 54 fisheries and 25 vessel groups...... (tracking of vessels shifting between groups). Results show average stability of vessel activity in terms of the main fishery, along with a great diversity of secondary fisheries and some possibilities for shifting between gears and areas. We conclude that the level of technical interactions is high...

  4. [Chronic complications of diabetes mellitus. Recommendations from the American Diabetes Association 2011. Prevention and management].

    Science.gov (United States)

    Isla Pera, Pilar

    2012-09-01

    Diabetes mellitus (DM) is one of the diseases with greater impact public health, not only because of its high prevalence, but, above all, by the consequences of the chronic complications arising from this disease. Hyperglycemia generates damage both in the field of microcirculation and the great vessels causing injury, macroangiopathies and microangiopathies. Macroangiopathies complications are generated from alterations or injury in the great vessels of the arterial to the most important, being from the clinical point of view, ischemic heart disease, disease stroke and peripheral arterial disease. Microangiopathies complications are due to alterations or injury of small vessels being the most important, from a clinical point of view, nephropathy, retinopathy and diabetic neuropathy. Macroangiopathies complications are generated from alterations or injury in the great vessels of the arterial to the most important, being from the clinical point of view, ischemic heart disease, disease stroke and peripheral arterial disease. Microangiopathies complications are due to alterations or injury of small vessels being the most important, from a clinical point of view, nephropathy, retinopathy and diabetic neuropathy.

  5. Diagnostic value of electrocardiography, dynamic isotope studies and angiography in coronary heart disease

    International Nuclear Information System (INIS)

    Haas, J.

    1986-01-01

    The goal of this work is on the basis of the case histories of 36 patients with heart anamneses (27 with electrocardiographically and/or enzymatically detected heart infarcts, 9 with various cardial diseases) to test the diagnostic value of stress electrocardiograms, dynamic isotope examinations of the heart and coronary angiographies in the cases of myocardial infarcts, heart wall aneurysms, coronary heart disease and in the determination of the global discharge fraction, specifically broad scanning (heart front, side and back walls) as well as fine scanning (individual coronary vessel branches). In the case of myocardial infarct the stress EKG and the heart scintigraphy agree with one another to a large degree, whereby scintigraphy (with 99mTc-DPTA) in addition detects infarcted myocardial regions. In the diagnosis of heart wall aneurysms scintigraphy and ventriculography had the same results in 91.6% of the cases. Coronary heart disease results agreed for all three methods in 91.7% of the cases and with scintigraphy and angiography in 94.4%. The degree of agreement between scintigraphy and coronary angiography is confirmed in the literature. One-, two- and 3-vessel diseases can be determined with these two methods in 90 to 75% agreement. The result lies thereby above the values of 201Tl-myocardial scintigraphy given in the literature. Also the global discharge fraction shows scintigraphic as well as angiographic agreement of almost 90%. (TRV) [de

  6. Alien invasive species and biological pollution of the Great Lakes Basin ecosystem[Great Lakes Water Quality Board : Report to the International Joint Commission

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-05-01

    The displacement of important native species in the Great Lakes is a result of an invasion by a succession of non indigenous aquatic species. These invasion also resulted in interference with the proper human water uses and cost billions of dollars. The problem was considered serious enough that the International Joint Commission asked the Great Lakes Water Quality Board in 1999 to review the regulations in place and make recommendations, if necessary, for the implementation of additional measures that could be considered to keep control over the introduction of alien invasive species. Escapes from aquaria, aquaculture, research and educational facilities, canal and diversion water flows, and release of live bait are all sources of this invasion. The effectiveness of alternative technologies to control the invasion was to be examined by the Board. Other efforts taking place to address the situation in the basin are being complemented by the publication of this report. It is considered that the most important source of alien invasive species (AIS) to the Great Lakes is the discharge of ballast water from shipping vessels coming from outside the United States and Canada. A major concern is the role played by vessels reporting no ballast on board (NOBOB) upon entering the basin. A number of recommendations were made concerning: (1) implementation and enforcement of the ballast water discharge standards agreed upon by both countries, (2) the evaluation of the effectiveness of alternative technologies to achieve ballast water discharge standards over the long term, combined with the use of chemical treatment while the evaluation is being performed, (3) the implementation of optimal management practices to control sediments in shipping vessels, (4) modifications to the design of shipping vessels, and (5) the monitoring and contingency plans in the event of a repeat scenario in the future. Composed of an equal number representatives from the United States and Canada, at

  7. Potential implications of the helical heart in congenital heart defects.

    Science.gov (United States)

    Corno, Antonio F; Kocica, Mladen J

    2007-01-01

    The anatomic and functional observations made by Francisco Torrent-Guasp, in particular his discovery of the helical ventricular myocardial band (HVMB), have challenged what has been taught to cardiologists and cardiac surgeons over centuries. A literature debate is ongoing, with interdependent articles and comments from supporters and critics. Adequate understanding of heart structure and function is obviously indispensable for the decision-making process in congenital heart defects. The HVMB described by Torrent-Guasp and the potential impact on the understanding and treatment of congenital heart defects has been analyzed in the following settings: embryology, ventriculo-arterial discordance (transposition of great arteries), Ebstein's anomaly, pulmonary valve regurgitation after repair of tetralogy of Fallot, Ross operation, and other congenital heart defects. The common structural spiral feature is only one of the elements responsible for the functional interaction of right and left ventricles, and understanding the form/function relationship in congenital heart defects is more difficult than for acquired heart disease because of the variety and complexity of congenital heart defects. Individuals involved in the care of patients with congenital heart defects have to be stimulated to consider further investigations and alternative surgical strategies.

  8. Joint Modelling of Longitudinal and Survival Data with Applications in Heart Valve Data

    NARCIS (Netherlands)

    E-R. Andrinopoulou (Eleni-Rosalina)

    2014-01-01

    markdownabstract__Abstract__ The heart is one of the most important organs in the entire human body. Specifically, it is a pump composed of muscle which pumps blood throughout the blood vessels to various parts of the body by repeated rhythmic contractions. The four heart valves determine the

  9. Air Quality and Heart Health: An Emerging Topic for Heart ...

    Science.gov (United States)

    Air Quality and Heart Health: An Emerging Topic for Heart Month: Ambient air particle pollution increases short- and long-term cardiovascular morbidity and mortality. Older-people, those with pre-existing heart disease and lung disease and diabetes are at higher risk. Mechanisms are under investigation and are likely related to oxidative stress, inflammation and effects on autonomic control. Improvements in air pollution levels reduce health impacts and increase life expectancy. Reductions of short-term exposure in those at highest risk are predicted to mitigate adverse health effects. EPA regularly evaluates the standards, health risks and issues improved standards when needed. Public health action is needed along with EPA standards to reduce the public health burden of short- and long-term adverse health effects of air pollution. Health risks remain and need to be addressed through integrated efforts of public health, health care, environmental health, individuals and communities. Presented at Webinar for the National Association of Clean Air Agencies, February 2, 2017, Chapel Hill, NC- This webinar provided an update of environmental health information related to the effects of air pollution and heart and blood vessel disease. Such information is critically important for the Clean Air Agencies to understand as it provides the justification of their actions.

  10. The pacemaker activity generating the intrinsic myogenic contraction of the dorsal vessel of Tenebrio molitor (Coleoptera).

    Science.gov (United States)

    Markou, T; Theophilidis, G

    2000-11-01

    Combined intracellular and extracellular recordings from various parts of the isolated dorsal vessel of Tenebrio molitor revealed some of the following electrophysiological properties of the heart and the aorta. (i) The wave of depolarization causing forward pulsation of the dorsal vessel was always transmitted from posterior to anterior, with a conduction velocity of 0.014 m s(-1) in the heart and 0.001 m s(-1) in the aorta when the heart rate was 60 beats min(-1). (ii) There was no pacemaker activity in the aorta. (iii) The duration of the compound action potential in the aortic muscle depended on the duration of the pacemaker action potential generated in the heart. (iv) Isolated parts of the heart continued to contract rhythmically for hours, indicating powerful pacemaker activity in individual cardiac segments. (v) There was a direct relationship between action potential duration and the length of the preceding diastolic interval. (vi) The rhythmic wave of depolarization was dependent on the influx of Ca(2+). (vii) The recovery of the electrical properties of myocardial cells that had been disrupted by sectioning was rapid. (viii) In hearts sectioned into two halves, the rhythmic pacemaker action potentials recorded simultaneously from the two isolated halves eventually drifted out of phase, but they had the same intrinsic frequency. In the light of these data, we discuss two alternative models for the generation of spontaneous rhythmic pumping movements of the heart and aorta.

  11. Acquired heart conditions in adults with congenital heart disease: a growing problem.

    Science.gov (United States)

    Tutarel, Oktay

    2014-09-01

    The number of adults with congenital heart disease is increasing due to the great achievements in the field of paediatric cardiology, congenital heart surgery and intensive care medicine over the last decades. Mortality has shifted away from the infant and childhood period towards adulthood. As congenital heart disease patients get older, a high prevalence of cardiovascular risk factors is encountered similar to the general population. Consequently, the contribution of acquired morbidities, especially acquired heart conditions to patient outcome, is becoming increasingly important. Therefore, to continue the success story of the last decades in the treatment of congenital heart disease and to further improve the outcome of these patients, more attention has to be given to the prevention, detection and adequate therapy of acquired heart conditions. The aim of this review is to give an overview about acquired heart conditions that may be encountered in adults with congenital heart disease. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  12. Therapeutic Cardiac Catheterizations for Children with Congenital Heart Disease

    Science.gov (United States)

    ... communicate between arteries and veins. These abnormal vessels cause the heart to work harder than it needs to. They should be eliminated when possible. After Catheterization When your child arrives in the recovery area, he or she ...

  13. [Morphological pathology of vessels in granulomatosis with polyangiitis (Wegener's disease)].

    Science.gov (United States)

    Zerbino, D D; Zimba, E A

    2015-01-01

    to investigate the incidence of injuries in different vascular beds and the morphopathological changes in vessels in granulomatosis with polyangiitis. The morphopathological features of vascular injuries were investigated in 11 dead patients aged 16--74 years with granulomatosis with polyangiitis. Proliferative and destructive angiitis with predominant involvement of microcirculatory vessels and with development of necrosis-prone granulomas in their walls and perivascularly was established to underlie the clinical manifestations of granulomatosis with polyangiitis. The most typical localization of the pathologic process is the vessels of the upper respiratory tract, lungs, and kidneys. Cardiopulmonary and renal failures are causes of death in the majority of cases. It should be noted that the vessels of the heart, liver, and gastrointestinal tract are frequently involved in the pathological process. Vascular changes in these organs determine the clinical features of granulomatosis with polyangiitis and lead to a number of fatal complications. Granulomatosis with polyangiitis is a systemic disease with polymorphism of clinical manifestations, which requires in-depth analysis based on current precision patient examination methods, including a histopathological study.

  14. Automated control of the laser welding process of heart valve scaffolds

    Directory of Open Access Journals (Sweden)

    Weber Moritz

    2016-09-01

    Full Text Available Using the electrospinning process the geometry of a heart valve is not replicable by just one manufacturing process. To produce heart valve scaffolds the heart valve leaflets and the vessel have to be produced in separated spinning processes. For the final product of a heart valve they have to be mated afterwards. In this work an already existing three-axes laser was enhanced to laser weld those scaffolds. The automation control software is based on the robot operating system (ROS. The mechatronically control is done by an Arduino Mega. A graphical user interface (GUI is written with Python and Kivy.

  15. EFSA Panel on Dietetic Products, Nutrition and Allergies (NDA); Scientific Opinion on the substantiation of a health claim related to vitamin K2 and contribution to the normal function of the heart and blood vessels (ID 125, further assessment) pursuant to Article 13(1) of Regulation (EC) No 1924/2006

    DEFF Research Database (Denmark)

    Tetens, Inge

    Following a request from the European Commission, pursuant to Article 13 of Regulation (EC) No 1924/2006, the Panel on Dietetic Products, Nutrition and Allergies was asked to provide a scientific opinion on a health claim related to vitamin K2 and contribution to the normal function of the heart...... and blood vessels. The food constituent that is the subject of the claim, vitamin K2, is sufficiently characterised. The claimed effect, contribution to the normal function of the heart and blood vessels, is a beneficial physiological effect. The proposed target population is the general population......, that the results of two prospective cohort studies are in conflict regarding the risk of coronary heart disease associated with vitamin K2 intakes, that high intakes of vitamin K2 were associated with a significantly lower degree of aortic calcification in one prospective cohort study after adjustment...

  16. 46 CFR 199.610 - Exemptions for vessels in specified services.

    Science.gov (United States)

    2010-10-01

    ... Specified Services Section or paragraph in this part Service Oceans Coastwise Great Lakes Lakes, Bays, and... helpless person can be observed from the navigating bridge; and A(iii) the vessel does not regularly engage...

  17. MRI of the Chest

    Medline Plus

    Full Text Available ... It’s also used to assess the anatomy and function of the heart and its blood flow. Tell ... that is important to assess the health and function of these structures (heart, valves, great vessels, etc.). ...

  18. Great Lakes Surface Ice Reports from U.S. Coast Guard

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Data consist of ice observations from U.S. Coast Guard vessels operating on the Great Lakes, and from Coast Guard shore stations reported via teletype messages and...

  19. μCT of ex-vivo stained mouse hearts and embryos enables a precise match between 3D virtual histology, classical histology and immunochemistry

    Science.gov (United States)

    Larsson, Emanuel; Martin, Sabine; Lazzarini, Marcio; Tromba, Giuliana; Missbach-Guentner, Jeannine; Pinkert-Leetsch, Diana; Katschinski, Dörthe M.; Alves, Frauke

    2017-01-01

    The small size of the adult and developing mouse heart poses a great challenge for imaging in preclinical research. The aim of the study was to establish a phosphotungstic acid (PTA) ex-vivo staining approach that efficiently enhances the x-ray attenuation of soft-tissue to allow high resolution 3D visualization of mouse hearts by synchrotron radiation based μCT (SRμCT) and classical μCT. We demonstrate that SRμCT of PTA stained mouse hearts ex-vivo allows imaging of the cardiac atrium, ventricles, myocardium especially its fibre structure and vessel walls in great detail and furthermore enables the depiction of growth and anatomical changes during distinct developmental stages of hearts in mouse embryos. Our x-ray based virtual histology approach is not limited to SRμCT as it does not require monochromatic and/or coherent x-ray sources and even more importantly can be combined with conventional histological procedures. Furthermore, it permits volumetric measurements as we show for the assessment of the plaque volumes in the aortic valve region of mice from an ApoE-/- mouse model. Subsequent, Masson-Goldner trichrome staining of paraffin sections of PTA stained samples revealed intact collagen and muscle fibres and positive staining of CD31 on endothelial cells by immunohistochemistry illustrates that our approach does not prevent immunochemistry analysis. The feasibility to scan hearts already embedded in paraffin ensured a 100% correlation between virtual cut sections of the CT data sets and histological heart sections of the same sample and may allow in future guiding the cutting process to specific regions of interest. In summary, since our CT based virtual histology approach is a powerful tool for the 3D depiction of morphological alterations in hearts and embryos in high resolution and can be combined with classical histological analysis it may be used in preclinical research to unravel structural alterations of various heart diseases. PMID:28178293

  20. 46 CFR 11.462 - Endorsements for master or mate of uninspected fishing industry vessels.

    Science.gov (United States)

    2010-10-01

    ... applies to endorsements for masters and mates of all vessels, however propelled navigating the high seas... master or mate of uninspected fishing industry vessels are issued for either ocean or near-coastal routes... years of total service on ocean or near coastal routes. Service on Great Lakes or inland waters may...

  1. A thresholding based technique to extract retinal blood vessels from fundus images

    Directory of Open Access Journals (Sweden)

    Jyotiprava Dash

    2017-12-01

    Full Text Available Retinal imaging has become the significant tool among all the medical imaging technology, due to its capability to extract many data which is linked to various eye diseases. So, the accurate extraction of blood vessel is necessary that helps the eye care specialists and ophthalmologist to identify the diseases at the early stages. In this paper, we have proposed a computerized technique for extraction of blood vessels from fundus images. The process is conducted in three phases: (i pre-processing where the image is enhanced using contrast limited adaptive histogram equalization and median filter, (ii segmentation using mean-C thresholding to extract retinal blood vessels, (iii post-processing where morphological cleaning operation is used to remove isolated pixels. The performance of the proposed method is tested on and experimental results show that our method achieve an accuracies of 0.955 and 0.954 on Digital retinal images for vessel extraction (DRIVE and Child heart and health study in England (CHASE_DB1 databases respectively.

  2. Study of imaging time shortening in Whole Heart MRCA. Evaluation of slice thickness

    International Nuclear Information System (INIS)

    Iwai, Mitsuhiro; Tateishi, Toshiki; Takeda, Soji; Hayashi, Ryuji

    2005-01-01

    A series of examinations in cardiac MR imaging, such as cine, perfusion, MR coronary angiography (MRCA) and viability, is generally known as One Stop Cardiac Examination. It takes about 40 to 60 minutes to perform One Stop Cardiac Examination, and Whole Heart MRCA accounts for most of the examination time. Therefore, we aimed to shorten imaging time of Whole Heart MRCA, especially in a large imaging area such as that in the case of the postoperative evaluation of a bypass graft, by investigating the depiction of a diameter of mimic blood vessels as changing the slice thickness of Whole Heart MRCA. The results showed that the maximum slice thickness of about 1 mm was excellent considering the diameters of actual coronary arteries are about 3 mm. In this study, we could grasp the relationships among slice thickness of Whole Heart MRCA, the diameter of a blood vessel, and shortened examination time. We suggested that it was useful for selecting the suitable sequence depending on a patient's conditions. (author)

  3. Relationship between lung-to-heart uptake ratio of technetium-99m-tetrofosmin during exercise myocardial single photon emission computed tomographic imaging and the number of diseased coronary arteries in patients with effort angina pectoris without myocardial infarction

    International Nuclear Information System (INIS)

    Okajima, Toshiya; Ueshima, Kenji; Nishiyama, Osamu; Ogawa, Muneyoshi; Ohuchi, Mami; Saitoh, Masahiko; Hiramori, Katsuhiko

    2004-01-01

    Increased lung uptake of thallium-201 in exercise myocardial perfusion imaging is a reliable marker of multivessel disease in patients with ischemic heart disease. This study investigated whether the lung-to-heart uptake ratio with technetium-99m ( 99m Tc)-tetrofosmin also provides valuable information to detect patients with multivessel disease. Fifty-three consecutive patients (35 men, 18 women, mean age 66±11 years; single-vessel disease: 29, double-vessel disease: 16, triple-vessel disease: 8) with stable effort angina pectoris without prior myocardial infarction and 17 control subjects (12 men, 5 women, mean age 62±9 years) underwent exercise myocardial perfusion imaging with 99m Tc-tetrofosmin and coronary angiography in January 2000 to December 2002. The lung-to-heart uptake ratio was calculated on an anterior projection before reconstruction of the exercise single photon emission computed tomographic images. The mean lung-to-heart uptake ratio was 0.34±0.04, 0.38±0.07, 0.41±0.05, and 0.46±0.09, in patients with normal coronary, single-vessel disease, double-vessel disease, and triple-vessel disease, respectively. Significantly higher lung-to-heart uptake ratio was associated with more diseased vessels (p 99m Tc-tetrofosmin can provide clinically useful information to detect multivessel disease in patients with ischemic heart disease. (author)

  4. The normal heart - Part I. The cardiac outline and chamber anatomy

    International Nuclear Information System (INIS)

    Walker, J.

    1985-01-01

    The heart is the most open and the most secret object in all radiology. Surrounded by alveolar air (its natural contrast) its outline dominates the chest X-ray. The lung vessels, responding to any change in function, are openly displayed, but within the heart borders the X-ray shadow is obscure and its parts invisible; moreover its vital purpose, movement, is not seen. This hollow muscular organ is conical, its apex points downwards, forwards and to the left at 60 0 to the midline. It is roughly 12 cm in length and weighs about 350 g. The main vessels enter and leave at the base posteriorly. Its apex is free within the serous cavity of the pericardium but its base is fixed by vessels and by the pericardial reflexions which surround them. The embryonic dorsal mesopericardium between arteries and veins breaks down to give the transverse sinus which frees the heart posteriorly, and the reflexions around the pulmonary veins form a blind sac, the oblique sinus, which opens to the left. All is enclosed by fibrous pericardium and occupies the anterior mediastinum at the level of the 6th-9th dorsal vertebrae from which it is separated by the oesophagus, aorta and spinal muscles. It rests on the central tendon of the diaphragm and laterally the right and left lungs envelop it over more than two thirds of its surface

  5. Guidelines to Visualize Vessels in a Geographic Information System

    OpenAIRE

    Rodighiero, Dario

    2010-01-01

    In information systems the data representation covers a great importance. In fact the visualization of information is the last point of contact between the user and the information system. This is the space where the communication takes place. In real-time monitoring systems, this passage covers a great importance, especially for reasons related to the time and the transparency of relevant information. These factors are fundamental to vessel monitoring systems. This is the beginning where we ...

  6. Sealing analysis for nuclear vessel of PWR

    International Nuclear Information System (INIS)

    Qu, J.; Dou, Y.

    1987-01-01

    Although design by analysis of pressure vessel has become a requirement in all codes for more than 20 years, sealing design for nuclear components is still too complicated and there are yet no criteria about this aspect, even though in the well-known ASME Boiler and Pressure Vessel Code. Thus it is of significance to undertake researches of transient sealing tests and analysis for nuclear vessel. Since 1960s great progress has been made in analytic computer program, which takes flange as a rigid ring. Actually, however, there are elastic or elastoplastic contacts on flange mating surface. Chen (1979) gave a mixed finite element method, using a condensing flexible matrix skill, to solve two-body contact problem. On the basis of axisymmetric stress and thermal analysis of finite element method and on accepting Chen's (1979) idea of mixed finite element method, we have developed a computer program for sealing analysis, named SMEC, which considers bolt loading changes and temperature effects. (orig./GL)

  7. The challenge of staphylococcal pacemaker endocarditis in a patient with transposition of the great arteries endocarditis in congenital heart disease

    International Nuclear Information System (INIS)

    Ch'ng, Julie; Chan, William; Lee, Paul; Joshi, Subodh; Grigg, Leanne E.; Ajani, Andrew E.

    2003-01-01

    Staphylococcus aureus is a leading cause of septicaemia and infective endocarditis. The overall incidence of staphylococcal bacteraemia is increasing, contributing to 16% of all hospital-acquired bacteraemias. The use of cardiac pacemakers has revolutionized the management of rhythm disturbances, yet this has also resulted in a group of patients at risk of pacemaker lead endocarditis and seeding in the range of 1% to 7%. We describe a 26-year-old man with transposition of the great arteries who had a pacemaker implanted and presented with S. aureus septicaemia 2 years postpacemaker implantation and went on to develop pacemaker lead endocarditis. This report illustrates the risk of endocarditis in the population with congenital heart disease and an intracardiac device

  8. Rac1-PAK2 pathway is essential for zebrafish heart regeneration

    Energy Technology Data Exchange (ETDEWEB)

    Peng, Xiangwen [State Key Laboratory of Genetic Engineering, Department of Genetics, School of Life Sciences, Fudan University, Shanghai 201203 (China); He, Quanze [Center for Reproduction and Genetics, Suzhou Municipal Hospital, Jiangsu 215002 (China); Li, Guobao; Ma, Jinmin [State Key Laboratory of Genetic Engineering, Department of Genetics, School of Life Sciences, Fudan University, Shanghai 201203 (China); Zhong, Tao P., E-mail: taozhongfudan@yahoo.com [State Key Laboratory of Genetic Engineering, Department of Genetics, School of Life Sciences, Fudan University, Shanghai 201203 (China); Department of Medicine, Vanderbilt University School of Medicine, TN 37232 (United States)

    2016-04-15

    P-21 activated kinases, or PAKs, are serine–threonine kinases that play important roles in diverse heart functions include heart development, cardiovascular development and function in a range of models; however, the mechanisms by which PAKs mediate heart regeneration are unknown. Here, we demonstrate that PAK2 and PAK4 expression is induced in cardiomyocytes and vessels, respectively, following zebrafish heart injury. Inhibition of PAK2 and PAK4 using a specific small molecule inhibitor impedes cardiomyocyte proliferation/dedifferentiation and cardiovascular regeneration, respectively. Cdc42 is specifically expressed in the ventricle and may function upstream of PAK2 but not PAK4 under normal conditions and that cardiomyocyte proliferentation during heart regeneration relies on Rac1-mediated activation of Pak2. Our results indicate that PAKs play a key role in heart regeneration.

  9. Rac1-PAK2 pathway is essential for zebrafish heart regeneration

    International Nuclear Information System (INIS)

    Peng, Xiangwen; He, Quanze; Li, Guobao; Ma, Jinmin; Zhong, Tao P.

    2016-01-01

    P-21 activated kinases, or PAKs, are serine–threonine kinases that play important roles in diverse heart functions include heart development, cardiovascular development and function in a range of models; however, the mechanisms by which PAKs mediate heart regeneration are unknown. Here, we demonstrate that PAK2 and PAK4 expression is induced in cardiomyocytes and vessels, respectively, following zebrafish heart injury. Inhibition of PAK2 and PAK4 using a specific small molecule inhibitor impedes cardiomyocyte proliferation/dedifferentiation and cardiovascular regeneration, respectively. Cdc42 is specifically expressed in the ventricle and may function upstream of PAK2 but not PAK4 under normal conditions and that cardiomyocyte proliferentation during heart regeneration relies on Rac1-mediated activation of Pak2. Our results indicate that PAKs play a key role in heart regeneration.

  10. Cardiovascular cast model fabrication and casting effectiveness evaluation in fetus with severe congenital heart disease or normal heart.

    Science.gov (United States)

    Wang, Yu; Cao, Hai-yan; Xie, Ming-xing; He, Lin; Han, Wei; Hong, Liu; Peng, Yuan; Hu, Yun-fei; Song, Ben-cai; Wang, Jing; Wang, Bin; Deng, Cheng

    2016-04-01

    To investigate the application and effectiveness of vascular corrosion technique in preparing fetal cardiovascular cast models, 10 normal fetal heart specimens with other congenital disease (control group) and 18 specimens with severe congenital heart disease (case group) from induced abortions were enrolled in this study from March 2013 to June 2015 in our hospital. Cast models were prepared by injecting casting material into vascular lumen to demonstrate real geometries of fetal cardiovascular system. Casting effectiveness was analyzed in terms of local anatomic structures and different anatomical levels (including overall level, atrioventricular and great vascular system, left-sided and right-sided heart), as well as different trimesters of pregnancy. In our study, all specimens were successfully casted. Casting effectiveness analysis of local anatomic structures showed a mean score from 1.90±1.45 to 3.60±0.52, without significant differences between case and control groups in most local anatomic structures except left ventricle, which had a higher score in control group (P=0.027). Inter-group comparison of casting effectiveness in different anatomical levels showed no significant differences between the two groups. Intra-group comparison also revealed undifferentiated casting effectiveness between atrioventricular and great vascular system, or left-sided and right-sided heart in corresponding group. Third-trimester group had a significantly higher perfusion score in great vascular system than second-trimester group (P=0.046), while the other anatomical levels displayed no such difference. Vascular corrosion technique can be successfully used in fabrication of fetal cardiovascular cast model. It is also a reliable method to demonstrate three-dimensional anatomy of severe congenital heart disease and normal heart in fetus.

  11. 78 FR 49544 - Great Lakes Pilotage Advisory Committee; Vacancies

    Science.gov (United States)

    2013-08-14

    .... ADDRESSES: Send your cover letter and resume indicating the membership category for which you are applying... pilotage of vessels on the Great Lakes, and at least 5 years of practical experience in maritime operations..., national origin, political affiliation, sexual orientation, gender identity, marital status, disability and...

  12. Numerical modeling of dynamics of heart rate and arterial pressure during passive orthostatic test

    Science.gov (United States)

    Ishbulatov, Yu. M.; Kiselev, A. R.; Karavaev, A. S.

    2018-04-01

    A model of human cardiovascular system is proposed to describe the main heart rhythm, influence of autonomous regulation on frequency and strength of heart contractions and resistance of arterial vessels; process of formation of arterial pressure during systolic and diastolic phases; influence of respiration; synchronization between loops of autonomous regulation. The proposed model is used to simulate the dynamics of heart rate and arterial pressure during passive transition from supine to upright position. Results of mathematical modeling are compared to original experimental data.

  13. The Semantics of Heart: Translation Problems

    Directory of Open Access Journals (Sweden)

    Hortensia Pârlog

    2005-06-01

    Full Text Available Words hardly ever occur on their own, because they can hardly mean anything on their own, when asked about the meaning of an isolated word, in order to figure it out, what one does is try to place it in a context or use it in a collocation. The verbal contexts in which words appear influence or at least clarify their semantic value, it is because of contextual factors that a word may have more than one meaning. Therefore, the analysis above word level is extremely important. An analysis of translational decisions may also prove to be a valuable source of information in establishing the semantics of a lexical item. The above statements are illustrated by discussing the semantics of heart. The word occurs in a great number of structures in both English and Romanian, of which eight will be analysed: heart + verb, verb + heart, heart + of phrase, adjective + heart, heart + head noun, head noun +of heart, adjective + preposition + heart, heart in sayings or fixed expressions.

  14. Problems in manufacturing and transport of pressure vessels of integral reactors

    International Nuclear Information System (INIS)

    Kralovec, J.

    1997-01-01

    Integral water-cooled reactors are typical with eliminating large-diameter primary pipes and placing primary components, i.e. steam generators and pressurizers in reactor vessels. This arrangement leads to reactor pressure vessels of large dimensions: diameters, heights and thick walls and subsequently to great weights. Thus, even medium power units have pressure vessels which are on the very limit of present manufacturing capabilities. Principal manufacturing and inspection operations as well as pertinent equipment are concerned: welding, cladding, heat treatment, machining, shop-handling, non-destructive testing, hydraulic pressure tests etc. Tile transport of such a large and heavy component makes a problem which effects its design as well as the selection of the plant site. Railway, road and ship are possible ways of transport each of them having its advantages and limitations. Specific features and limits of the manufacture and transport of large pressure vessels are discussed in the paper. (author)

  15. Stress analysis of hydride bed vessels used for tritium storage

    International Nuclear Information System (INIS)

    McKillip, S.T.; Bannister, C.E.; Clark, E.A.

    1991-01-01

    A prototype hydride storage bed, using LaNi 4.25 Al 0.75 as the storage material, was fitted with strain gages to measure strains occurring in the stainless steel bed vessel caused by expansion of the storage powder upon uptake of hydrogen. The strain remained low in the bed as hydrogen was added, up to a bed loading of about 0.5 hydrogen to metal atom ratio (H/M). The strain then increased with increasing hydrogen loading (∼ 0.8 H/M). Different locations exhibited greatly different levels of maximum strain. In no case was the design stress of the vessel exceeded

  16. 76 FR 61696 - New York State Prohibition of Discharges of Vessel Sewage; Receipt of Petition and Tentative...

    Science.gov (United States)

    2011-10-05

    ... Clean Vessel Act: Pumpout Station and Dump Station Technical Guidelines (Federal Register, Vol. 59, No.... The Lake serves as an economic engine for the region and a place of great natural beauty, heavily used... Rochester reported that ``honey dipper'' trucks have come in to pumpout commercial vessels on occasion while...

  17. Pharmaceutical interventions to influence arteriogenesis: new concepts to treat ischemic heart disease

    NARCIS (Netherlands)

    Hoefer, Imo E.; Piek, Jan J.; Pasterkamp, Gerard

    2006-01-01

    Despite the technical progress in interventional techniques to overcome the harmful effects of ischemic heart disease there is still an urgent need for alternative, pharmaceutical treatment modalities. Exogenous stimulation of vessel growth, i.e. vasculogenesis, angiogenesis or arteriogenesis serves

  18. MODIFICATION OF THE NUSS PROCEDURE-PREVENTION OF INJURIES OF THE HEART AND MAJOR BLOOD VESSELS

    Directory of Open Access Journals (Sweden)

    Mirko Žganjer

    2012-09-01

    Full Text Available Objective: The Nuss procedure is a widely accepted technique for correcting pectus excavatum. Unfortunately, fatal complications such as cardiac perforation and injury of the great blood vessels have been noticed in a few patients.We modified original Nuss technique to be simpler and lessdangerous.Methods: We modified Nuss procedure with the sternal elevation to improve sternal depression. Modified Nuss procedure was carried out by applying metal lifter raise sterum until the patient starts to raise from the operating table. The space behind sternum is now wider, and surgeryhas become safer with less probability of injuries intrathoracic organs. We compared 46 patients operated by the original Nuss method (taking into account the data from the literature on complications of the original method on a large series of patients with 54 patients operated by a modified Nuss method.Results: Before lifting the sternum depth of the deformity was between 2.9 and 6.2 cm (mean 5.4 cm, and the increase were between 1.5 and 4.0 cm (mean 2.8 cm. The difference of 2.6 cm is large enough, and the width of introducer and bars are about 3 mm for securely passed along the chest.Conclusions: A modified method of treating pectus excavatum is safer, better and with fewer complications than the original method of Nuss.

  19. RISK FACTORS IN CHILD CONGENITAL MALFORMATIONS

    OpenAIRE

    Alina-Costina LUCA; Mirabela SUBOTNICU

    2015-01-01

    Congenital heart malformations are among the most common congenital malformations. Congenital heart malformations occur due to genetic and environmental factors during embryonic morphogenesis period of the heart. About 25% of these malformations are severe, requiring intervention immediately after birth or in infancy. Abnormalities of structure and function of the heart and great vessels are the consequence of teratogenic factors occurring between day 19 and 45 of gestation. (Yagel et al...

  20. MR imaging of the heart: functional imaging

    International Nuclear Information System (INIS)

    Croisille, P.; Revel, D.

    2000-01-01

    To date, most applications of cardiovascular MRI relate to the evaluation of major vessels rather than the heart itself. However, MRI plays a major role in the evaluation of specific types of cardiovascular pathology, namely intracardiac and paracardiac masses, pericardial disease, and congenital heart disease. In addition, because the visualization of cardiovascular anatomy with MR is non-invasive and permits three-dimensional analysis but also allows functional assessment of the cardiac pump, it is clear that MRI will have a growing and significant impact over the next years. We review some of the technical aspect of cardiac MRI and describe the current and potential clinical and investigative applications of this new methodology. (orig.)

  1. Research on fiber Bragg grating heart sound sensing and wavelength demodulation method

    Science.gov (United States)

    Zhang, Cheng; Miao, Chang-Yun; Gao, Hua; Gan, Jing-Meng; Li, Hong-Qiang

    2010-11-01

    Heart sound includes a lot of physiological and pathological information of heart and blood vessel. Heart sound detecting is an important method to gain the heart status, and has important significance to early diagnoses of cardiopathy. In order to improve sensitivity and reduce noise, a heart sound measurement method based on fiber Bragg grating was researched. By the vibration principle of plane round diaphragm, a heart sound sensor structure of fiber Bragg grating was designed and a heart sound sensing mathematical model was established. A formula of heart sound sensitivity was deduced and the theoretical sensitivity of the designed sensor is 957.11pm/KPa. Based on matched grating method, the experiment system was built, by which the excursion of reflected wavelength of the sensing grating was detected and the information of heart sound was obtained. Experiments show that the designed sensor can detect the heart sound and the reflected wavelength variety range is about 70pm. When the sampling frequency is 1 KHz, the extracted heart sound waveform by using the db4 wavelet has the same characteristics with a standard heart sound sensor.

  2. Diagnostics carried by a light multipurpose deployer for vacuum vessel interventions

    Energy Technology Data Exchange (ETDEWEB)

    Houry, M., E-mail: Michael.houry@cea.fr [CEA-IRFM, F-13108 Saint-Paul-Lez-Durance (France); Gargiulo, L.; Balorin, C.; Bruno, V.; Keller, D.; Roche, H. [CEA-IRFM, F-13108 Saint-Paul-Lez-Durance (France); Kammerer, N.; Measson, Y. [CEA, LIST, F-92265 Fontenay-aux-Roses (France); Carrel, F.; Schoepff, V. [CEA, LIST, F-91191 Gif-sur-Yvette (France)

    2011-10-15

    ITER will greatly rely on remote-handling operations to accomplish its scientific missions. Robotic systems will also be required to operate inside vacuum vessels in order to limit or replace human access, to intervene quickly between experimental sessions for in-vessel inspections and measurements, and to preserve the machine conditioning and thus improve machine availability. In this prospect, a multipurpose carrier prototype called Articulated Inspection Arm (AIA) was developed by CEA laboratories within the European work program. With an embedded camera, it successfully demonstrated close inspection feasibility inside Tore Supra tokamak. The AIA robot was designed for mini-invasive operations with interchangeable diagnostics to be plugged at its head. This covers various applications for the safety, the operation and the scientific mission (in-vessel inspection, plasma diagnostics calibrations or inner components analysis and treatments). This paper presents recent analysis and results obtain with diagnostics developed by CEA for in-vessel remote-handling intervention.

  3. Diagnostics carried by a light multipurpose deployer for vacuum vessel interventions

    International Nuclear Information System (INIS)

    Houry, M.; Gargiulo, L.; Balorin, C.; Bruno, V.; Keller, D.; Roche, H.; Kammerer, N.; Measson, Y.; Carrel, F.; Schoepff, V.

    2011-01-01

    ITER will greatly rely on remote-handling operations to accomplish its scientific missions. Robotic systems will also be required to operate inside vacuum vessels in order to limit or replace human access, to intervene quickly between experimental sessions for in-vessel inspections and measurements, and to preserve the machine conditioning and thus improve machine availability. In this prospect, a multipurpose carrier prototype called Articulated Inspection Arm (AIA) was developed by CEA laboratories within the European work program. With an embedded camera, it successfully demonstrated close inspection feasibility inside Tore Supra tokamak. The AIA robot was designed for mini-invasive operations with interchangeable diagnostics to be plugged at its head. This covers various applications for the safety, the operation and the scientific mission (in-vessel inspection, plasma diagnostics calibrations or inner components analysis and treatments). This paper presents recent analysis and results obtain with diagnostics developed by CEA for in-vessel remote-handling intervention.

  4. Deterministic Approach to Detect Heart Sound Irregularities

    Directory of Open Access Journals (Sweden)

    Richard Mengko

    2017-07-01

    Full Text Available A new method to detect heart sound that does not require machine learning is proposed. The heart sound is a time series event which is generated by the heart mechanical system. From the analysis of heart sound S-transform and the understanding of how heart works, it can be deducted that each heart sound component has unique properties in terms of timing, frequency, and amplitude. Based on these facts, a deterministic method can be designed to identify each heart sound components. The recorded heart sound then can be printed with each component correctly labeled. This greatly help the physician to diagnose the heart problem. The result shows that most known heart sounds were successfully detected. There are some murmur cases where the detection failed. This can be improved by adding more heuristics including setting some initial parameters such as noise threshold accurately, taking into account the recording equipment and also the environmental condition. It is expected that this method can be integrated into an electronic stethoscope biomedical system.

  5. The risk of coronary heart disease of seafarers on vessels sailing under a German flag.

    Science.gov (United States)

    Oldenburg, Marcus; Jensen, Hans-Joachim; Latza, Ute; Baur, Xaver

    2010-01-01

    This study aimed to predict the risk of coronary heart disease (CHD) among seafarers on German-flagged vessels and to assess the association of shipboard job duration at sea with the risk of CHD. During the legally required medical fitness test for nautical service, 161 seafarers in Hamburg participated in a cross-sectional study which included an interview, blood sampling, and blood pressure measurements (response 84.9%). The predicted 10-year risk of an acute coronary event of the examined German seafarers aged 35 to 64 years (n = 46) was assessed in comparison with a sample of male German employees of the same age working ashore (PROCAM study). The number of independent CHD risk factors (according to the PROCAM study) was compared in the groups with 'shorter' and 'longer' median shipboard job duration at sea (15.0 years). The examined German seafarers had a similar age-standardized predicted 10-year CHD risk as the German reference population. Nearly all independent CHD risk factors were significantly more frequent in seamen with job duration at sea of ≥ 15 years than in those with 〈 15 years. After adjusting for age, the number of CHD risk factors was associated with job duration (OR 1.08 [95% CI 1.02-1.14] per year). Seafarers on German-flagged ships have to attend a medical fitness test for nautical service every 2 years. Thus, it can be assumed that seafarers present a healthier population than employees ashore. In this study, however, CHD risk of seafarers was similar to that of the reference population. This may indicate that working onboard implies a high coronary risk. Furthermore, the study results suggest a tendency of increased risk of CHD among seafarers with longer job duration at sea.

  6. Primo vessel inside a lymph vessel emerging from a cancer tissue.

    Science.gov (United States)

    Lee, Sungwoo; Ryu, Yeonhee; Cha, Jinmyung; Lee, Jin-Kyu; Soh, Kwang-Sup; Kim, Sungchul; Lim, Jaekwan

    2012-10-01

    Primo vessels were observed inside the lymph vessels near the caudal vena cava of a rabbit and a rat and in the thoracic lymph duct of a mouse. In the current work we found a primo vessel inside the lymph vessel that came out from the tumor tissue of a mouse. A cancer model of a nude mouse was made with human lung cancer cell line NCI-H460. We injected fluorescent nanoparticles into the xenografted tumor tissue and studied their flow in blood, lymph, and primo vessels. Fluorescent nanoparticles flowed through the blood vessels quickly in few minutes, and but slowly in the lymph vessels. The bright fluorescent signals of nanoparticles disappeared within one hour in the blood vessels but remained much longer up to several hours in the case of lymph vessels. We found an exceptional case of lymph vessels that remained bright with fluorescence up to 24 hours. After detailed examination we found that the bright fluorescence was due to a putative primo vessel inside the lymph vessel. This rare observation is consistent with Bong-Han Kim's claim on the presence of a primo vascular system in lymph vessels. It provides a significant suggestion on the cancer metastasis through primo vessels and lymph vessels. Copyright © 2012. Published by Elsevier B.V.

  7. Introduction to cardiac imaging in infants and children: Techniques, potential, and role in the imaging work-up of various cardiac malformations and other pediatric heart conditions

    Energy Technology Data Exchange (ETDEWEB)

    Bailliard, Frederique [Centre for Cardiovascular MR, Cardiothoracic Unit, UCL Institute of Child Health and Great Ormond Street Hospital for Children, London (United Kingdom); North Carolina Children' s Heart Center, Department of Pediatrics, University of North Carolina at Chapel Hill (United States); Hughes, Marina L. [Centre for Cardiovascular MR, Cardiothoracic Unit, UCL Institute of Child Health and Great Ormond Street Hospital for Children, London (United Kingdom); Taylor, Andrew M. [Centre for Cardiovascular MR, Cardiothoracic Unit, UCL Institute of Child Health and Great Ormond Street Hospital for Children, London (United Kingdom)], E-mail: a.taylor@ich.ucl.ac.uk

    2008-11-15

    The increasing prevalence of congenital heart disease (CHD) can be attributed to major improvements in diagnosis and treatment. Although echocardiography is the most commonly used imaging modality for diagnosis and follow-up of subjects with CHD, the evolution of cardiovascular magnetic resonance (MR) imaging and increasingly computed tomography (CT) does offer new ways to visualize the heart and the great vessels. The development of cardiovascular MR techniques allows for a comprehensive assessment of cardiac anatomy and function. This provides information about the long-term sequlae of the underlying complex anatomy, hemodynamic assessment of residual post-operative lesions and complications of surgery. As much of the functional data in CHD patients is usually acquired with invasive X-ray angiography, non-invasive alternatives such as cardiovascular MR (and CT) are desirable. This review evaluates the role of MR imaging in the management of subjects with CHD, particularly detailing recent developments in imaging techniques as they relate to the various CHD diagnoses we commonly encounter in our practice.

  8. Building foundations for transcatheter intervascular anastomoses: 3D anatomy of the great vessels in large experimental animals

    NARCIS (Netherlands)

    Sizarov, Aleksander; de Bakker, Bernadette S.; Klein, Karina; Ohlerth, Stefanie

    2014-01-01

    To provide comprehensive illustrations of anatomy of the relevant vessels in large experimental animals in an interactive format as preparation for developing an effective and safe transcatheter technique of aortopulmonary and bidirectional cavopulmonary intervascular anastomoses. Computed

  9. Endoscopic visualization of luminal organ and great vessels with three dimensional CT scanner

    International Nuclear Information System (INIS)

    Kobayashi, Hisashi; Okumura, Toshiyuki; Amemiya, Ryuta; Hasegawa, Hiroshi

    1992-01-01

    Thirty cases examined by three dimensional CT scanner (3DCT) are reported. The observation of inner view using 3DCT were performed in 12 large vessels with vascular disorder, 10 pulmonary bronchi with lung cancer and 8 common bile ducts involved obstructive disease. In order to visualize interface of the lumen, a new software, which was developed by HITACHI MEDICO Inc., was used. In all cases but one the inner view of the luminal organ was clearly demonstrated as 3D images and it was possible to judge some changes of luminal interface involved by the diseases. The 3DCT endoscopic image might be useful as a new endoscopic technique without fiberscopy. (author)

  10. Interventional Cardiology for Congenital Heart Disease.

    Science.gov (United States)

    Kenny, Damien

    2018-05-01

    Congenital heart interventions are now replacing surgical palliation and correction in an evolving number of congenital heart defects. Right ventricular outflow tract and ductus arteriosus stenting have demonstrated favorable outcomes compared to surgical systemic to pulmonary artery shunting, and it is likely surgical pulmonary valve replacement will become an uncommon procedure within the next decade, mirroring current practices in the treatment of atrial septal defects. Challenges remain, including the lack of device design focused on smaller infants and the inevitable consequences of somatic growth. Increasing parental and physician expectancy has inevitably lead to higher risk interventions on smaller infants and appreciation of the consequences of these interventions on departmental outcome data needs to be considered. Registry data evaluating congenital heart interventions remain less robust than surgical registries, leading to a lack of insight into the longer-term consequences of our interventions. Increasing collaboration with surgical colleagues has not been met with necessary development of dedicated equipment for hybrid interventions aimed at minimizing the longer-term consequences of scar to the heart. Therefore, great challenges remain to ensure children and adults with congenital heart disease continue to benefit from an exponential growth in minimally invasive interventions and technology. This can only be achieved through a concerted collaborative approach from physicians, industry, academia and regulatory bodies supporting great innovators to continue the philosophy of thinking beyond the limits that has been the foundation of our specialty for the past 50 years. Copyright © 2018. The Korean Society of Cardiology.

  11. Role of the 3-Vessel and Trachea View in Antenatal Detection of Tetralogy of Fallot.

    Science.gov (United States)

    Palatnik, Anna; Grobman, William A; Cohen, Leeber S; Dungan, Jeffrey S; Gotteiner, Nina L

    2016-08-01

    Prenatal diagnosis of tetralogy of Fallot remains less frequent compared to other major congenital heart defects. In this study, we examined how often the 3-vessel and trachea view was abnormal in a large series of prenatally diagnosed cases of tetralogy of Fallot. In addition, we compared its sensitivity to that of the traditional outflow tract views for detection of tetralogy of Fallot. We found that both views were abnormal in all fetuses with tetralogy of Fallot, showing reversed aortic-to-pulmonary valve and aortic arch isthmus-to-ductus arteriosus ratios in the outflow tract and 3-vessel and trachea views, respectively. However, as a single measured marker, the enlarged aortic arch isthmus on the 3-vessel and trachea view appears to be the most sensitive for tetralogy of Fallot.

  12. Doppler echocardiography in pediatric cardiology

    International Nuclear Information System (INIS)

    Allen, H.D.; Marx, G.R.

    1986-01-01

    Congenital heart disease encompasses abnormalities in cardiac development which generally have in common either valve stenoses or connections between chambers or great vessels. Usually, abnormalities of intracardiac anatomy, and often, abnormalities of great vessel anatomy, can be unraveled by two-dimensional echocardiography. However, echocardiography offers little information regarding flow characteristics in the various congenital lesions. Addition of the Doppler principle, particularly when combined with the two-dimensional examination, can characterize the source of a flow disturbance, quantify gradients across a site of obstruction, and quantify flow volume across sites where flow is nonturbulent. These features make Doppler echocardiography unique for noninvasive accurate evaluation of children and adults with various forms of congenital heart disease. In this report, the authors discuss some of the present uses of Doppler echocardiography in congenital heart disease. Application of this technique requires greater understanding of certain physics principles than does routine echocardiography

  13. MRI of the Chest

    Medline Plus

    Full Text Available ... provides movie-like sequential imaging of the cardiovascular system that is important to assess the health and function of these structures (heart, valves, great vessels, etc.). top ...

  14. Planning of vessel grafts for reconstructive surgery in congenital heart diseases

    Science.gov (United States)

    Rietdorf, U.; Riesenkampff, E.; Schwarz, T.; Kuehne, T.; Meinzer, H.-P.; Wolf, I.

    2010-02-01

    The Fontan operation is a surgical treatment for patients with severe congenital heart diseases, where a biventricular correction of the heart can't be achieved. In these cases, a uni-ventricular system is established. During the last step of surgery a tunnel segment is placed to connect the inferior caval vein directly with the pulmonary artery, bypassing the right atrium and ventricle. Thus, the existing ventricle works for the body circulation, while the venous blood is passively directed to the pulmonary arteries. Fontan tunnels can be placed intra- and extracardially. The location, length and shape of the tunnel must be planned accurately. Furthermore, if the tunnel is placed extracardially, it must be positioned between other anatomical structures without constraining them. We developed a software system to support planning of the tunnel location, shape, and size, making pre-operative preparation of the tunnel material possible. The system allows for interactive placement and adjustment of the tunnel, affords a three-dimensional visualization of the virtual Fontan tunnel inside the thorax, and provides a quantification of the length, circumferences and diameters of the tunnel segments. The visualization and quantification can be used to plan and prepare the tunnel material for surgery in order to reduce the intra-operative time and to improve the fit of the tunnel patch.

  15. Transposition of the great arteries in MRI; Transposition der grossen Arterien im MRT des Herzens

    Energy Technology Data Exchange (ETDEWEB)

    Zaehringer, C.; Leiner, T.; Maki, J.H.; Potthast, S.

    2014-02-15

    The contribution on transposition of the great arteries (TGA) in the heart NMR images covers the following issues: different forms of TGA (dextro-TGA and levo-TGA), therapeutic options, long-term complication of TGA and the importance of heart NMR imaging in case of TGA.

  16. Tissue-engineered vascular grafts for use in the treatment of congenital heart disease: from the bench to the clinic and back again.

    Science.gov (United States)

    Patterson, Joseph T; Gilliland, Thomas; Maxfield, Mark W; Church, Spencer; Naito, Yuji; Shinoka, Toshiharu; Breuer, Christopher K

    2012-05-01

    Since the first tissue-engineered vascular graft (TEVG) was implanted in a child over a decade ago, growth in the field of vascular tissue engineering has been driven by clinical demand for improved vascular prostheses with performance and durability similar to an autologous blood vessel. Great strides were made in pediatric congenital heart surgery using the classical tissue engineering paradigm, and cell seeding of scaffolds in vitro remained the cornerstone of neotissue formation. Our second-generation bone marrow cell-seeded TEVG diverged from tissue engineering dogma with a design that induces the recipient to regenerate vascular tissue in situ. New insights suggest that neovessel development is guided by cell signals derived from both seeded cells and host inflammatory cells that infiltrate the graft. The identification of these signals and the regulatory interactions that influence cell migration, phenotype and extracellular matrix deposition during TEVG remodeling are yielding a next-generation TEVG engineered to guide neotissue regeneration without the use of seeded cells. These developments represent steady progress towards our goal of an off-the-shelf tissue-engineered vascular conduit for pediatric congenital heart surgery.

  17. Acute myocardial infarction after mediastinal radiotherapy

    International Nuclear Information System (INIS)

    Gagliardi, Juan; Tezanos Pinto, Miguel; Avalos, Adolfo; Sarubbi, Augusto; Padilla, Lucio; Espinosa, Daniel

    2004-01-01

    Mediastinal radiotherapy can affect the heart and great vessels to different degrees. It may turn up as coronary heart disease and less frequently as acute myocardial infarction. We report the case of a patient without coronary risk factors and an antecedent of mediastinal radiotherapy for Hodgkin's lymphoma. Considerations about mediastinal radiation as a risk factor for early development of coronary heart diseases are exposed. (author) [es

  18. Migration of a Central Venous Catheter in a Hemodialysis Patient Resulted in Left Atrial Perforation and Thrombus Formation Requiring Open Heart Surgery.

    Science.gov (United States)

    Wong, Kevin; Marks, Barry A; Qureshi, Anwer; Stemm, Joseph J

    2016-07-01

    Central venous catheterization is widely used in patients on hemodialysis. A rare complication associated with the clinical use of central venous catheters is perforation of the heart or major vessels. We report a case of inadvertent perforation of the left atrium and thrombosis after the placement of a hemodialysis catheter in the right internal jugular vein. In such cases, surgical removal of the central venous catheter from perforation sites in the heart and vessel walls poses anesthetic challenges because of the high risk of pneumothorax, hemorrhage, arrhythmias, thrombosis, and death.

  19. Experience with computed transmission tomography of the heart in vivo

    International Nuclear Information System (INIS)

    Carlsson, E.; Lipton, M.J.; Skioeldebrand, C.G.; Berninger, W.H.; Redington, R.W.

    1980-01-01

    Cardiac computed tomography in its present form provides useful information about the heart for clinical use in patients with heart disease and for investigative work in such patients and living animals. Its great reconstructive power and unmatched density resolution are particularly advantageous in the study of ischemic heart disease. Because of its non-invasive character cardiac computed tomography has the potential of becoming an effective screening tool for large numbers of patients with suspected or known coronary heart desiase. Other cardiac conditions such as valve disease and congenital lesions can also be examined with high diagnostic yield. However presently available scanners suffer from low repetion rate, long scan times and the fact that only one transverse cardiac level at a time can be obtained. The development which must be accomplished in order to eliminate these weaknesses is technically feasible. The availability of a dynamic cardiac scanner would greatly benefit the treatment of patients with heart disease and facilitate the inquiry into the pathophysiology of such diseases. (orig.) [de

  20. Prevalence of cerebral and pulmonary thrombosis in patients with cyanotic congenital heart disease

    DEFF Research Database (Denmark)

    Jensen, A S; Idorn, L; Thomsen, C

    2015-01-01

    BACKGROUND: Patients with cyanotic congenital heart disease (CCHD) have a high prevalence of thrombosis, the most frequently described locations being the cerebral and pulmonary vessels. The reported prevalence of both cerebral infarction and pulmonary thrombosis has been highly variable. The aim...

  1. A robust technique based on VLM and Frangi filter for retinal vessel extraction and denoising.

    Directory of Open Access Journals (Sweden)

    Khan Bahadar Khan

    Full Text Available The exploration of retinal vessel structure is colossally important on account of numerous diseases including stroke, Diabetic Retinopathy (DR and coronary heart diseases, which can damage the retinal vessel structure. The retinal vascular network is very hard to be extracted due to its spreading and diminishing geometry and contrast variation in an image. The proposed technique consists of unique parallel processes for denoising and extraction of blood vessels in retinal images. In the preprocessing section, an adaptive histogram equalization enhances dissimilarity between the vessels and the background and morphological top-hat filters are employed to eliminate macula and optic disc, etc. To remove local noise, the difference of images is computed from the top-hat filtered image and the high-boost filtered image. Frangi filter is applied at multi scale for the enhancement of vessels possessing diverse widths. Segmentation is performed by using improved Otsu thresholding on the high-boost filtered image and Frangi's enhanced image, separately. In the postprocessing steps, a Vessel Location Map (VLM is extracted by using raster to vector transformation. Postprocessing steps are employed in a novel way to reject misclassified vessel pixels. The final segmented image is obtained by using pixel-by-pixel AND operation between VLM and Frangi output image. The method has been rigorously analyzed on the STARE, DRIVE and HRF datasets.

  2. Magnetic resonance imaging for evaluation of congenital heart disease

    International Nuclear Information System (INIS)

    Niwa, Koichiro; Uchishiba, Mika; Tateno, Shigeru; Aotsuka, Hiroyuki; Nakatani, Hayao; Matsuo, Kozo; Fujiwara, Tadashi; Tashima, Kazuyuki.

    1992-01-01

    We applied the segmental analysis of cardiac MR images for evaluation of congenital heart diseases (CHD). One hundred and ninety-three patients with CHD, ranging in age from 20 days to 18 years old, were studied by MRI. This study compared the effectiveness of MRI with cardiac angiography and echocardiography for the evaluation of major diagnosis of CHD and all components of cardiovascular anatomy. ECG-gated MRI was performed by spin echo and gradient refocused imaging techniques operating at 0.5 tesla. In all the patients not only cardiovascular anatomies of CHD but all structures relevant to the identification of arrangement of organs were displayed. In diagnosing a total of 193 of major cardiac anomalies and 741 segments of the vein, the atrium, the ventricle and the great vessels by MRI and angiocardiogram and/or echocardiogram, descrepancies were found in 6 patients (3.1%), and only 18 segments (2.4%), respectively. For vascular and complex cardiac anatomies MRI was able to provide good anatomical details. Based on these findings, the segmental analysis of cardiac MR images was found useful for achieving a systematic diagnosis of CHD. (author)

  3. Radiology trainer. Torso, internal organs and vessels. 2. ed.; Radiologie-Trainer. Koerperstamm, innere Organe und Gefaesse

    Energy Technology Data Exchange (ETDEWEB)

    Staebler, Axel [Orthopaedische Klinik Harlaching, Muenchen (Germany). Radiologische Praxis; Erlt-Wagner, Birgit (eds.) [Klinikum der Universitaet Muenchen (Germany). Inst. fuer Klinische Radiologie

    2013-11-01

    The radiology training textbook is based on case studies of the clinical experience, including radiological imaging and differential diagnostic discussion. The scope of this volume covers the torso, internal organs and vessels. The following issues are discussed: lungs, pleura, mediastinum; heart and vascular system; upper abdomen organs; gastrointestinal tract; urogenital system.

  4. Medical Tests and Procedures for Finding and Treating Heart and Blood Vessel Disease

    Science.gov (United States)

    ... Coronary calcium scan Health care providers use electron-beam computed tomography (to-MOG-rah-fee) (EBCT) or ... how the heart performs during activity, such as walking on a moving treadmill. A medication stress test ...

  5. A system for rapid prototyping of hearts with congenital malformations based on the medical imaging interaction toolkit (MITK)

    Science.gov (United States)

    Wolf, Ivo; Böttger, Thomas; Rietdorf, Urte; Maleike, Daniel; Greil, Gerald; Sieverding, Ludger; Miller, Stephan; Mottl-Link, Sibylle; Meinzer, Hans-Peter

    2006-03-01

    Precise knowledge of the individual cardiac anatomy is essential for diagnosis and treatment of congenital heart disease. Complex malformations of the heart can best be comprehended not from images but from anatomic specimens. Physical models can be created from data using rapid prototyping techniques, e.g., lasersintering or 3D-printing. We have developed a system for obtaining data that show the relevant cardiac anatomy from high-resolution CT/MR images and are suitable for rapid prototyping. The challenge is to preserve all relevant details unaltered in the produced models. The main anatomical structures of interest are the four heart cavities (atria, ventricles), the valves and the septum separating the cavities, and the great vessels. These can be shown either by reproducing the morphology itself or by producing a model of the blood-pool, thus creating a negative of the morphology. Algorithmically the key issue is segmentation. Practically, possibilities allowing the cardiologist or cardiac surgeon to interactively check and correct the segmentation are even more important due to the complex, irregular anatomy and imaging artefacts. The paper presents the algorithmic and interactive processing steps implemented in the system, which is based on the open-source Medical Imaging Interaction Toolkit (MITK, www.mitk.org). It is shown how the principles used in MITK enable to assemble the system from modules (functionalities) developed independently from each other. The system allows to produce models of the heart (and other anatomic structures) of individual patients as well as to reproduce unique specimens from pathology collections for teaching purposes.

  6. Guidelines versus reality: is coronary stent application in three-vessel disease standard or the exception?

    Science.gov (United States)

    Linder, Roland; Zeidler, J; Verheyen, F; von der Schulenburg, J-M Graf; Haverich, A; Schilling, T

    2017-08-19

    The national guidelines for treatment of chronic coronary heart disease (CHD) recommend surgical coronary aortic bypass grafting (CABG) rather than percutaneous coronary intervention (PCI) for patients with a coronary three-vessel disease. The epidemiology of three-vessel CHD and data about the application of different revascularisation strategies raise suspicion of deviation from the guidelines in the treatment of those patients. Claims data containing records of almost 10 million patients of the largest German statutory health insurance fund (Techniker Krankenkasse) were utilised to measure adherence to the guidelines for treatment of groups of patients with one-, two-, and three-vessel CHD, respectively. The impact of age, sex, and comorbidity on each patient's revascularisation procedure was investigated as well. There was no significant difference in the rate of PCI between the groups. In conclusion, the hypothesis that patients with a coronary three-vessel disease are not always treated according to the recommendations of the national guidelines could not be disproved by this study. Finally, the results of this study suggest that the best revascularisation strategy for each patient with two- and three-vessel disease should be decided upon by an interdisciplinary discussion between both cardiologists and cardiac surgeons.

  7. The work of Jules Horowitz. The great Cea actors

    International Nuclear Information System (INIS)

    Arnaudet, L.; Deloche, R.; Procope, L.

    1999-01-01

    Jules Horowitz contributed to the heart calculation of the first french reactor Zoe. He developed the first experimental reactors, invested himself in the reactors physics and helped with EDF to the realisation of the French electronuclear programme. His work is marked out the building of great research devices: The Laue-Langevin Institute (ILL), The European Source of Synchrotron radiation (ESRF), the great national heavy ions accelerator (GANIL) the superconductor tokamak TORE SUPRA) the Leon Brillouin Laboratory (LLB), the Frederic Joliot hospital service (SHFJ). (N.C.)

  8. Trends in the utilization of computed tomography and cardiac catheterization among children with congenital heart disease.

    Science.gov (United States)

    Yang, Justin Cheng-Ta; Lin, Ming-Tai; Jaw, Fu-Shan; Chen, Shyh-Jye; Wang, Jou-Kou; Shih, Tiffany Ting-Fang; Wu, Mei-Hwan; Li, Yiu-Wah

    2015-11-01

    Pediatric cardiac computed tomography (CT) is a noninvasive imaging modality used to clearly demonstrate the anatomical detail of congenital heart diseases. We investigated the impact of cardiac CT on the utilization of cardiac catheterization among children with congenital heart disease. The study sample consisted of 2648 cardiac CT and 3814 cardiac catheterization from 1999 to 2009 for congenital heart diseases. Diagnoses were categorized into 11 disease groups. The numbers of examination, according to the different modalities, were compared using temporal trend analyses. The estimated effective radiation doses (mSv) of CT and catheterization were calculated and compared. The number of CT scans and interventional catheterizations had a slight annual increase of 1.2% and 2.7%, respectively, whereas that of diagnostic catheterization decreased by 6.2% per year. Disease groups fell into two categories according to utilization trend differences between CT and diagnostic catheterization. The increased use of CT reduces the need for diagnostic catheterization in patients with atrioventricular connection disorder, coronary arterial disorder, great vessel disorder, septal disorder, tetralogy of Fallot, and ventriculoarterial connection disorder. Clinicians choose either catheterization or CT, or both examinations, depending on clinical conditions, in patients with semilunar valvular disorder, heterotaxy, myocardial disorder, pericardial disorder, and pulmonary vein disorder. The radiation dose of CT was lower than that of diagnostic cardiac catheterization in all age groups. The use of noninvasive CT in children with selected heart conditions might reduce the use of diagnostic cardiac catheterization. This may release time and facilities within the catheterization laboratory to meet the increasing demand for cardiac interventions. Copyright © 2014. Published by Elsevier B.V.

  9. Understanding the C-pulse device and its potential to treat heart failure.

    Science.gov (United States)

    Sales, Virna L; McCarthy, Patrick M

    2010-03-01

    The Sunshine Heart C-Pulse (C-Pulse; Sunshine Heart Inc., Tustin, CA) device is an extra-aortic implantable counterpulsation pump designed as a non-blood contacting ambulatory heart assist device, which may provide relief from symptoms for class II-III congestive heart failure patients. It has a comparable hemodynamic augmentation to intra-aortic balloon counterpulsation devices. The C-Pulse cuff is implanted through a median sternotomy, secured around the ascending aorta, and pneumatically driven by an external system controller. Pre-clinical studies in the acute pig model, and initial temporary clinical studies in patients undergoing off-pump coronary bypass surgery have shown substantial increase in diastolic perfusion of the coronary vessels, which translated to a favorable improvement in ventricular function. A U.S. prospective multi-center trial to evaluate the safety and efficacy of the C-Pulse in class III patients with moderate heart failure is now in progress.

  10. Detecting culprit vessel of coronary artery disease with SPECT 99Tcm-MIBI myocardial imaging

    International Nuclear Information System (INIS)

    Luan Zhaosheng; Zhou Wen; Peng Yong; Su Yuwen; Tian Jianhe; Gai lue; Sun Zhijun

    2002-01-01

    Objective: To assess the value of detecting culprit vessel of coronary artery disease (CAD) with SPECT 99 Tc m -MIBI myocardial imaging. Methods: Forty-six patients with CAD were studied. Every patients had multiple-vessel lesion showed by coronary arteriography and was treated by revascularization as percutaneous transluminal angioplasty (PTCA), coronary artery bypass graft (CABG) or laser holing. Exercise (EX), rest (RE) and intravenous infusion of nitroglycerine (NTG) SPECT 99 Tc m -MIBI myocardial imagings were performed before revascularization. Exercise and rest images revealed the myocardial ischemia. NTG images revealed myocardial viability. Culprit vessels were detected according to the defects showed by above mentioned images. The veracity of detected culprit vessels was tested with the outcome of the reperfusion therapy. Results: In this group, the coronary arteriography revealed 107 lesioned coronary arteries. Myocardial imaging detected 46 culprit vessels including 23 left anterior descending (LAD), 19 left circumflex coronary artery (LCX) and 4 right coronary artery (RCA). All 46 culprit vessels underwent revascularization and had nice outcome. The veracity of 99 Tc m -MIBI myocardial imaging detected culprit vessels was high according to patients' outcome. Conclusion: Exercise, rest and NTG 99 Tc m -MIBI myocardial imaging is a great method for detecting culprit vessels in multivessel coronary disease

  11. The evolution of heart gene delivery vectors

    Science.gov (United States)

    Wasala, Nalinda B.; Shin, Jin-Hong; Duan, Dongsheng

    2012-01-01

    Gene therapy holds promise for treating numerous heart diseases. A key premise for the success of cardiac gene therapy is the development of powerful gene transfer vehicles that can achieve highly efficient and persistent gene transfer specifically in the heart. Other features of an ideal vector include negligible toxicity, minimal immunogenicity and easy manufacturing. Rapid progress in the fields of molecular biology and virology has offered great opportunities to engineer various genetic materials for heart gene delivery. Several nonviral vectors (e.g. naked plasmids, plasmid lipid/polymer complexes and oligonucleotides) have been tested. Commonly used viral vectors include lentivirus, adenovirus and adeno-associated virus. Among these, adeno-associated virus has shown many attractive features for pre-clinical experimentation in animal models of heart diseases. We review the history and evolution of these vectors for heart gene transfer. PMID:21837689

  12. [Age-related changes Kernogan`s index of venous vessels hollow and parenchymatous organs at stages of a postnatal ontogenesis].

    Science.gov (United States)

    Nickel', V V; Efremova, V P

    2016-01-01

    Kernogan`s index determination of hollow and parenchymatous organs' venous vessels was conducted on 80 men corpses of the three age groups. Average age of the investigated men corpses of the mature period is 27,8±4,2 years, elderly - 67,8±3,7 years, senile - 81,9±4,5 years. The age variability transformation of venous vessels bandwidth of lungs, kidneys, heart, stomach and ileum were obligate. It was revealed that the Kernogan`s index of venous vessels changes can be equally detected at different age periods. While, with the obsolence, there is a gradual indicator's decline, which is mostly discerned in parenchymatous organs, while for the hollow organs transformations are less essentic.

  13. Evaluation for In-Vessel Retention Capabilities with In-Vessel Injection and External Reactor Vessel Cooling

    International Nuclear Information System (INIS)

    Lee, Jeong Seong; Ryu, In Chul; Moon, Young Tae

    2016-01-01

    If the accident has not progressed to the point of substantial changes in the core geometry, establishing adequate cooling is as straightforward as re-establishing flow through the reactor core. However, if the accident has progressed to the point where the core geometry is substantially altered as a result of material melting and relocation, as was the case in the TMI-2 accident, the means of cooling the debris are not as straightforward. From this time on, the reactor core was either completely or nearly covered by water, with high pressure injection flow initiated shortly after three hours into the accident. However, the core debris was not coolable in this configuration and a substantial quantity of molten core material drained into the bypass region, with approximately twenty metric tons of molten debris draining into the reactor pressure vessel (RPV) lower head. Hence, the core configuration developed at approximately three hours into the accident was not coolable, even submerged in water. The purpose of this paper is to evaluate in-vessel retention capabilities with in-vessel injection (IVI) and external reactor vessel cooling (ERVC) available in a reactor application by using the integrated severe accident analysis code. The MAAP5 models were improved to facilitate evaluation of the in-vessel retention capability of APR1400. In-vessel retention capabilities have been analyzed for the APR1400 using the MAAP5.03 code. The results show that in-vessel retention is feasible when in-vessel injection is initiated within a relatively short time frame under the simulation condition used in the present study

  14. Evaluation for In-Vessel Retention Capabilities with In-Vessel Injection and External Reactor Vessel Cooling

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jeong Seong; Ryu, In Chul; Moon, Young Tae [KEPCO Engineering and Construction Co. Ltd., Deajeon (Korea, Republic of)

    2016-10-15

    If the accident has not progressed to the point of substantial changes in the core geometry, establishing adequate cooling is as straightforward as re-establishing flow through the reactor core. However, if the accident has progressed to the point where the core geometry is substantially altered as a result of material melting and relocation, as was the case in the TMI-2 accident, the means of cooling the debris are not as straightforward. From this time on, the reactor core was either completely or nearly covered by water, with high pressure injection flow initiated shortly after three hours into the accident. However, the core debris was not coolable in this configuration and a substantial quantity of molten core material drained into the bypass region, with approximately twenty metric tons of molten debris draining into the reactor pressure vessel (RPV) lower head. Hence, the core configuration developed at approximately three hours into the accident was not coolable, even submerged in water. The purpose of this paper is to evaluate in-vessel retention capabilities with in-vessel injection (IVI) and external reactor vessel cooling (ERVC) available in a reactor application by using the integrated severe accident analysis code. The MAAP5 models were improved to facilitate evaluation of the in-vessel retention capability of APR1400. In-vessel retention capabilities have been analyzed for the APR1400 using the MAAP5.03 code. The results show that in-vessel retention is feasible when in-vessel injection is initiated within a relatively short time frame under the simulation condition used in the present study.

  15. [Topography of the blood vessels in the hilum of the kidney of Myrmecophaga tridactyla].

    Science.gov (United States)

    Souza, W M; Miglino, M A; Arantes, I G; Nascimento, A A

    1991-01-01

    The study was undertaken in 10 formol-imbibed kidneys of great anteater (Myrmecophaga tridactyla). After the dissection the following characteristics were showed: kidney blood vessels are distributed in 2 different sites, namely hilar and extrahilar, amounting 3 to 6 in the right side 3 to 7 in the left side. Arterial branches in extrahilar region range from 1 to 2 in both sides and in hilar region they present from 1 to 4 in the right and 1 to 2 in the left. Venous roots occur in 1 to 2 vessels in the right and 1 to 3 vessels in the left, occupying only the hilar region, except one case where it was present in the right side.

  16. Heart Care in Japan: Before and After the 1995 Great Hanshin-Awaji Earthquake

    OpenAIRE

    Benedict, Timothy O.

    2016-01-01

    This paper examines the emergence of the term "heart care (kokoro no kea)" to describe the psychological support for disaster victims in the wake of the 1995 Hanshin earthquake. By comparing the usage of this term in the Yomiuri and Asahi newspapers before and after the earthquake, as well as its relationship with post-traumatic stress disorder (PTSD), this paper will show how heart care emerged in the context of hospice before expanding to include care for trauma more broadly. I will also di...

  17. Reliability analysis of pipelines and pressure vessels at nuclear power plants

    International Nuclear Information System (INIS)

    Klemin, A.I.; Shiverskij, E.A.

    1979-01-01

    Reliability analysis of pipelines and pressure vessels at NPP is given. The main causes and failure mechanisms of these elements, the ways of reliability improvement and preventing of great damages are considered. The reliability estimation methods both according to the statistical operation data and under the conditions of absence of failure statistics are given. The main characteristics and actual reliability factors of pipelines and pressure vessels of three home NPP: the first in the world NPP, VK-50 and Beloyarsk NPP, are presented. From the start-up there were practically no failures of the pipelines and pressure vessels at the VK-50 pilot installation. The analysis of the operation experience of the first and second blocks of the Beloyarsk NPP, as well as the first in the world NPP, shows that the most part of failures of the pipelines and pressure vessels of these energy blocks with the channel reactors is connected with the coolant leakage at minority pipelines of a small diameter. The most part of failures at individual pipelines of the first and second blocks of the Beloyarsk NPP are connected with the leakages of stuffing boxes of switching off devices. It is noted that serious failures of large pipelines and pressure vessels at all home NPP under operation have not been observed

  18. Predicting target vessel location on robot-assisted coronary artery bypass graft using CT to ultrasound registration

    International Nuclear Information System (INIS)

    Cho, Daniel S.; Linte, Cristian; Chen, Elvis C. S.; Bainbridge, Daniel; Wedlake, Chris; Moore, John; Barron, John; Patel, Rajni; Peters, Terry

    2012-01-01

    Purpose: Although robot-assisted coronary artery bypass grafting (RA-CABG) has gained more acceptance worldwide, its success still depends on the surgeon's experience and expertise, and the conversion rate to full sternotomy is in the order of 15%-25%. One of the reasons for conversion is poor pre-operative planning, which is based solely on pre-operative computed tomography (CT) images. In this paper, the authors propose a technique to estimate the global peri-operative displacement of the heart and to predict the intra-operative target vessel location, validated via both an in vitro and a clinical study. Methods: As the peri-operative heart migration during RA-CABG has never been reported in the literatures, a simple in vitro validation study was conducted using a heart phantom. To mimic the clinical workflow, a pre-operative CT as well as peri-operative ultrasound images at three different stages in the procedure (Stage 0 --following intubation; Stage 1 --following lung deflation; and Stage 2 --following thoracic insufflation) were acquired during the experiment. Following image acquisition, a rigid-body registration using iterative closest point algorithm with the robust estimator was employed to map the pre-operative stage to each of the peri-operative ones, to estimate the heart migration and predict the peri-operative target vessel location. Moreover, a clinical validation of this technique was conducted using offline patient data, where a Monte Carlo simulation was used to overcome the limitations arising due to the invisibility of the target vessel in the peri-operative ultrasound images. Results: For the in vitro study, the computed target registration error (TRE) at Stage 0 , Stage 1 , and Stage 2 was 2.1, 3.3, and 2.6 mm, respectively. According to the offline clinical validation study, the maximum TRE at the left anterior descending (LAD) coronary artery was 4.1 mm at Stage 0 , 5.1 mm at Stage 1 , and 3.4 mm at Stage 2 . Conclusions: The authors

  19. Multiple shell pressure vessel

    International Nuclear Information System (INIS)

    Wedellsborg, B.W.

    1988-01-01

    A method is described of fabricating a pressure vessel comprising the steps of: attaching a first inner pressure vessel having means defining inlet and outlet openings to a top flange, placing a second inner pressure vessel, having means defining inlet and outlet opening, concentric with and spaced about the first inner pressure vessel and attaching the second inner pressure vessel to the top flange, placing an outer pressure vessel, having inlet and outlet openings, concentric with and spaced apart about the second inner pressure vessel and attaching the outer pressure vessel to the top flange, attaching a generally cylindrical inner inlet conduit and a generally cylindrical inner outlet conduit respectively to the inlet and outlet openings in the first inner pressure vessel, attaching a generally cylindrical outer inlet conduit and a generally cylindrical outer outlet conduit respectively to the inlet and outlet opening in the second inner pressure vessel, heating the assembled pressure vessel to a temperature above the melting point of a material selected from the group, lead, tin, antimony, bismuth, potassium, sodium, boron and mixtures thereof, filling the space between the first inner pressure vessel and the second inner pressure vessel with material selected from the group, filling the space between the second inner pressure vessel and the outer pressure vessel with material selected from the group, and pressurizing the material filling the spaces between the pressure vessels to a predetermined pressure, the step comprising: pressurizing the spaces to a pressure whereby the wall of the first inner pressure vessel is maintained in compression during steady state operation of the pressure vessel

  20. Fine-grained visual marine vessel classification for coastal surveillance and defense applications

    Science.gov (United States)

    Solmaz, Berkan; Gundogdu, Erhan; Karaman, Kaan; Yücesoy, Veysel; Koç, Aykut

    2017-10-01

    The need for capabilities of automated visual content analysis has substantially increased due to presence of large number of images captured by surveillance cameras. With a focus on development of practical methods for extracting effective visual data representations, deep neural network based representations have received great attention due to their success in visual categorization of generic images. For fine-grained image categorization, a closely related yet a more challenging research problem compared to generic image categorization due to high visual similarities within subgroups, diverse applications were developed such as classifying images of vehicles, birds, food and plants. Here, we propose the use of deep neural network based representations for categorizing and identifying marine vessels for defense and security applications. First, we gather a large number of marine vessel images via online sources grouping them into four coarse categories; naval, civil, commercial and service vessels. Next, we subgroup naval vessels into fine categories such as corvettes, frigates and submarines. For distinguishing images, we extract state-of-the-art deep visual representations and train support-vector-machines. Furthermore, we fine tune deep representations for marine vessel images. Experiments address two scenarios, classification and verification of naval marine vessels. Classification experiment aims coarse categorization, as well as learning models of fine categories. Verification experiment embroils identification of specific naval vessels by revealing if a pair of images belongs to identical marine vessels by the help of learnt deep representations. Obtaining promising performance, we believe these presented capabilities would be essential components of future coastal and on-board surveillance systems.

  1. 33 CFR 90.3 - Pushing vessel and vessel being pushed: Composite unit.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Pushing vessel and vessel being... HOMELAND SECURITY INLAND NAVIGATION RULES INLAND RULES: INTERPRETATIVE RULES § 90.3 Pushing vessel and vessel being pushed: Composite unit. Rule 24(b) of the Inland Rules states that when a pushing vessel and...

  2. 33 CFR 82.3 - Pushing vessel and vessel being pushed: Composite unit.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Pushing vessel and vessel being... HOMELAND SECURITY INTERNATIONAL NAVIGATION RULES 72 COLREGS: INTERPRETATIVE RULES § 82.3 Pushing vessel and vessel being pushed: Composite unit. Rule 24(b) of the 72 COLREGS states that when a pushing vessel and a...

  3. Neutrophil-Mediated Delivery of Therapeutic Nanoparticles across Blood Vessel Barrier for Treatment of Inflammation and Infection

    OpenAIRE

    Chu, Dafeng; Gao, Jin; Wang, Zhenjia

    2015-01-01

    Endothelial cells form a monolayer in lumen of blood vessels presenting a great barrier for delivery of therapeutic nanoparticles (NPs) into extravascular tissues where most diseases occur, such as inflammation disorders and infection. Here, we report a strategy for delivering therapeutic NPs across this blood vessel barrier by nanoparticle in situ hitchhiking activated neutrophils. Using intravital microscopy of TNF-α-induced inflammation of mouse cremaster venules and a mouse model of acute...

  4. Heart Disease Doesn't Care What You Wear | NIH MedlinePlus the Magazine

    Science.gov (United States)

    ... version of this page please turn JavaScript on. Heart Disease Doesn't Care What You Wear Past Issues / ... matter how great you look on the outside, heart disease can strike on the inside. And being a ...

  5. Retinal Vessel Segmentation Based on Primal-Dual Asynchronous Particle Swarm Optimisation (pdAPSO Algorithm

    Directory of Open Access Journals (Sweden)

    E. G. Dada

    2017-04-01

    Full Text Available Acute damage to the retina vessel has been identified to be main reason for blindness and impaired vision all over the world. A timely detection and control of these illnesses can greatly decrease the number of loss of sight cases. Developing a high performance unsupervised retinal vessel segmentation technique poses an uphill task. This paper presents study on the Primal-Dual Asynchronous Particle Swarm Optimisation (pdAPSO method for the segmentation of retinal vessels. A maximum average accuracy rate 0.9243 with an average specificity of sensitivity rate of 0.9834 and average sensitivity rate of 0.5721 were achieved on DRIVE database. The proposed method produces higher mean sensitivity and accuracy rates in the same range of very good specificity.

  6. Relaxin 2 fails to lower intraocular pressure and to dilate retinal vessels in rats.

    Science.gov (United States)

    Hampel, Ulrike; Träger, Katharina; Liu, Hanhan; Teister, Julia; Grus, Franz; Prokosch-Willing, Verena

    2018-03-13

    Recently, the vasodilator relaxin 2 has been introduced as a treatment for acute heart failure. However, its role on vessels of the eye and intraocular pressure (IOP) remains unclear though it has been hypothesized to induce a decrease IOP after intramuscular injection in humans. We aimed to test whether the hormone relaxin 2 lowers IOP and dilates retinal vessels in animals. The IOP of female Sprague-Dawley rats before and after application of relaxin 2 was measured using an Icare Tonolab device calibrated for rats. Recombinant human relaxin 2 in phosphate-buffered saline with 0.1% bovine serum albumin was either applied as eye drops (1000, 2000 or 3000 ng/ml), injected intravitreally (500 ng/ml) or intravenously (13.3 μg/kg body weight). Retinal vessel thickness was monitored using infrared fundus images compiled with optical coherence tomography (Heidelberg Engineering) before and several time points after application of relaxin 2. Neither topical nor intravitreous or intravenous application of relaxin 2 lowered the IOP or changed the arterial or venous vessel diameter after 1 or 3 h after application. Now that relaxin 2 is more easily available, the hormone came again into focus as a potential glaucoma therapeutic. However, our study in rats could not support the hypothesis that relaxin 2 lowers IOP or dilates retinal vessels.

  7. Design and construction of Alborz tokamak vacuum vessel system

    International Nuclear Information System (INIS)

    Mardani, M.; Amrollahi, R.; Koohestani, S.

    2012-01-01

    Highlights: ► The Alborz tokamak is a D-shape cross section tokamak that is under construction in Amirkabir University of Technology. ► As one of the key components for the device, the vacuum vessel can provide ultra-high vacuum and clean environment for the plasma operation. ► A limiter is a solid surface which defines the edge of the plasma and designed to protect the wall from the plasma, localizes the plasma–surface interaction and localizes the particle recycling. ► Structural analyses were confirmed by FEM model for dead weight, vacuum pressure and plasma disruptions loads. - Abstract: The Alborz tokamak is a D-shape cross section tokamak that is under construction in Amirkabir University of Technology. At the heart of the tokamak is the vacuum vessel and limiter which collectively are referred to as the vacuum vessel system. As one of the key components for the device, the vacuum vessel can provide ultra-high vacuum and clean environment for the plasma operation. The VV systems need upper and lower vertical ports, horizontal ports and oblique ports for diagnostics, vacuum pumping, gas puffing, and maintenance accesses. A limiter is a solid surface which defines the edge of the plasma and designed to protect the wall from the plasma, localizes the plasma–surface interaction and localizes the particle recycling. Basic structure analyses were confirmed by FEM model for dead weight, vacuum pressure and plasma disruptions loads. Stresses at general part of the VV body are lower than the structure material allowable stress (117 MPa) and this analysis show that the maximum stresses occur near the gravity support, and is about 98 MPa.

  8. Safety analysis of nuclear containment vessels subjected to strong earthquakes and subsequent tsunamis

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Feng; Li, Hong Zhi [Dept. Structural Engineering, Tongji University, Shanghai (China)

    2017-08-15

    Nuclear power plants under expansion and under construction in China are mostly located in coastal areas, which means they are at risk of suffering strong earthquakes and subsequent tsunamis. This paper presents a safety analysis for a new reinforced concrete containment vessel in such events. A finite element method-based model was built, verified, and first used to understand the seismic performance of the containment vessel under earthquakes with increased intensities. Then, the model was used to assess the safety performance of the containment vessel subject to an earthquake with peak ground acceleration (PGA) of 0.56g and subsequent tsunamis with increased inundation depths, similar to the 2011 Great East earthquake and tsunami in Japan. Results indicated that the containment vessel reached Limit State I (concrete cracking) and Limit State II (concrete crushing) when the PGAs were in a range of 0.8–1.1g and 1.2–1.7g, respectively. The containment vessel reached Limit State I with a tsunami inundation depth of 10 m after suffering an earthquake with a PGA of 0.56g. A site-specific hazard assessment was conducted to consider the likelihood of tsunami sources.

  9. MRI of the Chest

    Medline Plus

    Full Text Available ... are the limitations of MRI of the Chest? What is MRI of the Chest? Magnetic resonance imaging ( ... heart, valves, great vessels, etc.). top of page What are some common uses of the procedure? MR ...

  10. MRI of the Chest

    Medline Plus

    Full Text Available ... important to assess the health and function of these structures (heart, valves, great vessels, etc.). top of ... room. In addition to affecting the MRI images, these objects can become projectiles within the MRI scanner ...

  11. The natural history of congenitally corrected transposition of the great arteries.

    Science.gov (United States)

    Huhta, James

    2011-01-01

    The natural history of congenitally corrected transposition of the great arteries is of clinical/surgical importance once the fetus is born without heart block or signs of heart failure. Without significant tricuspid valve malformation, associated defects such as ventricular septal defect and left ventricular outflow obstruction can be repaired surgically. The mortality and long-term outcome appear to be linked strongly with the severity of tricuspid valve regurgitation. Some patients with an intact ventricular septum and no right ventricular dysfunction will live long lives without detection, and some women will successfully complete pregnancy.

  12. 67Ga imaging in the patients with infective endocarditis after surgery for congenital heart disease

    International Nuclear Information System (INIS)

    Kohata, Tohru; Ono, Yasuo; Kamiya, Tetsuro; Nishimura, Tsunehiko; Takamiya, Makoto; Yagihara, Toshikatsu

    1991-01-01

    67 Ga imaging was performed in sixteen patients (age: 8 m.-18 y.) who had persistent fever and positive acute phase reactants after surgery for congenital heart disease. Abnormal uptake of 67 Ga over the heart and the lungs was evaluated with a computer. Abnormal uptake of 67 Ga was observed in seven patients. Of them, three showed it in the area of peripheral pulmonary artery and the other four showed it in the area of artificial vessels for pulmonary artery reconstruction. In six patients with positive blood cultures, five showed abnormal uptake of 67 Ga and in ten patients with negative blood cultures, two showed it. Vegetation was detected with 2D-echocardiography in four patients and all of them showed abnormal uptake of 67 Ga, while in 12 patients without vegetation three showed it. In conclusion, 67 Ga imaging was useful to detect the foci of infective endocarditis or pulmonary embolism caused by the vegetation in infective endocarditis in the patients after surgery for congenital heart disease, especially in the peripheral pulmonary arteries and artificial vessels which could not be detected with 2D-echo. (author)

  13. Vessel Operator System

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Operator cards are required for any operator of a charter/party boat and or a commercial vessel (including carrier and processor vessels) issued a vessel permit from...

  14. Comprehending the structure of a vacuum vessel and in-vessel components of fusion machines. 1. Comprehending the vacuum vessel structure

    International Nuclear Information System (INIS)

    Onozuka, Masanori; Nakahira, Masataka

    2006-01-01

    The functions, conditions and structure of vacuum vessel using tokamak fusion machines are explained. The structural standard and code of vacuum vessel, process of vacuum vessel design, and design of ITER vacuum vessel are described. Production and maintenance of ultra high vacuum, confinement of radioactive materials, support of machines in vessel and electromagnetic force, radiation shield, plasma vertical stability, one-turn electric resistance, high temperature baking heat and remove of nuclear heat, reduce of troidal ripple, structural standard, features of safety of nuclear fusion machines, subjects of structural standard of fusion vacuum vessel, design flow of vacuum vessel, establishment of radial build, selections of materials, baking and cooling method, basic structure, structure of special parts, shield structure, and of support structure, and example of design of structure, ITER, are stated. (S.Y.)

  15. Vascular targeting of LIGHT normalizes blood vessels in primary brain cancer and induces intratumoural high endothelial venules.

    Science.gov (United States)

    He, Bo; Jabouille, Arnaud; Steri, Veronica; Johansson-Percival, Anna; Michael, Iacovos P; Kotamraju, Venkata Ramana; Junckerstorff, Reimar; Nowak, Anna K; Hamzah, Juliana; Lee, Gabriel; Bergers, Gabriele; Ganss, Ruth

    2018-06-01

    High-grade brain cancer such as glioblastoma (GBM) remains an incurable disease. A common feature of GBM is the angiogenic vasculature, which can be targeted with selected peptides for payload delivery. We assessed the ability of micelle-tagged, vascular homing peptides RGR, CGKRK and NGR to specifically bind to blood vessels in syngeneic orthotopic GBM models. By using the peptide CGKRK to deliver the tumour necrosis factor (TNF) superfamily member LIGHT (also known as TNF superfamily member 14; TNFSF14) to angiogenic tumour vessels, we have generated a reagent that normalizes the brain cancer vasculature by inducing pericyte contractility and re-establishing endothelial barrier integrity. LIGHT-mediated vascular remodelling also activates endothelia and induces intratumoural high endothelial venules (HEVs), which are specialized blood vessels for lymphocyte infiltration. Combining CGKRK-LIGHT with anti-vascular endothelial growth factor and checkpoint blockade amplified HEV frequency and T-cell accumulation in GBM, which is often sparsely infiltrated by immune effector cells, and reduced tumour burden. Furthermore, CGKRK and RGR peptides strongly bound to blood vessels in freshly resected human GBM, demonstrating shared peptide-binding activities in mouse and human primary brain tumour vessels. Thus, peptide-mediated LIGHT targeting is a highly translatable approach in primary brain cancer to reduce vascular leakiness and enhance immunotherapy. Copyright © 2018 Pathological Society of Great Britain and Ireland. Published by John Wiley & Sons, Ltd. Copyright © 2018 Pathological Society of Great Britain and Ireland. Published by John Wiley & Sons, Ltd.

  16. Conjugate heat transfer analysis for in-vessel retention with external reactor vessel cooling

    International Nuclear Information System (INIS)

    Park, Jong-Woon; Bae, Jae-ho; Song, Hyuk-Jin

    2016-01-01

    Highlights: • A conjugate heat transfer analysis method is applied for in-vessel corium retention. • 3D heat diffusion has a formidable effect in alleviating focusing heat load from metallic layer. • The focusing heat load is decreased by about 2.5 times on the external surface. - Abstract: A conjugate heat transfer analysis method for the thermal integrity of a reactor vessel under external reactor vessel cooling conditions is developed to resolve light metal layer focusing effect issue for in-vessel retention. The method calculates steady-state three-dimensional temperature distribution of a reactor vessel using coupled conjugate heat transfer between in-vessel three-layered stratified corium (metallic pool, oxide pool and heavy metal and polar-angle dependent boiling heat transfer at the outer surface of a reactor vessel). The three-layer corium heat transfer model is utilizing lumped-parameter thermal-resistance circuit method. For the ex-vessel boiling boundary conditions, nucleate, transition and film boiling are considered. The thermal integrity of a reactor vessel is addressed in terms of heat flux at the outer-most nodes of the vessel and remaining thickness profile. The vessel three-dimensional heat conduction is validated against a commercial code. It is found that even though the internal heat flux from the metal layer goes far beyond critical heat flux (CHF) the heat flux from the outermost nodes of the vessel may be maintained below CHF due to massive vessel heat diffusion. The heat diffusion throughout the vessel is more pronounced for relatively low heat generation rate in an oxide pool. Parametric calculations are performed considering thermal conditions such as peak heat flux from a light metal layer, heat generation in an oxide pool and external boiling conditions. The major finding is that the most crucial factor for success of in-vessel retention is not the mass of the molten light metal above the oxide pool but the heat generation rate

  17. Evaluation of image quality on a per-patient, per-vessel, and per-segment basis by noninvasive coronary angiography with 64-section computed tomography. Dual-source versus single-source computed tomography

    International Nuclear Information System (INIS)

    Nakashima, Yoshiteru; Okada, Munemasa; Washida, Yasuo; Miura, Toshiro; Fujimura, Tatsuo; Nao, Tomoko; Matsunaga, Naofumi

    2011-01-01

    The purpose of this study was to evaluate the image quality (IQ) of dual-source CT (DSCT) versus single-source CT (SSCT). A total of 100 patients underwent 64-section CT coronary angiography (50 DSCT, 50 SSCT). Three observers evaluated the IQ of each coronary segment using a four-point scale (1, excellent; 2, good; 3, fair; 4, no assessment). The IQ of DSCT coronary angiography was compared with SSCT coronary angiography on a per-patient, per-vessel, and per-segment basis using the chi-squared test. The DSCT image quality score (IQS) was significantly lower on a per-patient basis and per-vessel basis for all vessels and on a per-segment basis for some segments (1, 2, 4PD, 4AV, 7, 9, 11, 12, 13) compared with SSCT. The DSCT IQS was significantly lower for certain segments (2, 4PD, 11, 13) with high heart rates (≥70 beats/min). The DSCT IQS was significantly lower for certain segments (1, 2, 3, 4PD, 4AV, 7, 8, 9, 10, 12, 13) with low heart rates (<70 beats/min). DSCT showed a significantly better IQ than SSCT, especially in patients with low heart rates. (author)

  18. Whole-heart MR coronary angiography - first results

    International Nuclear Information System (INIS)

    Ozgun, M.; Quante, M.; Fischbach, R.; Heindel, W.; Maintz, D.; Hoffmeier, A.; Botnar, R.

    2006-01-01

    Purpose: To evaluate a new coronary MR angiography technique covering the whole coronary artery tree in one data set acquisition. Materials and methods: Six healthy volunteers and 15 patients with known CAD were examined with a navigator gated and corrected (NAV) free-breathing 3D steady-state free precession sequence covering the whole heart (WH-MRA) (TR=5.4, TE-2.7, SENSE factor=2, 160 slices, 0.75 mm reconstructed slice thickness, in-plane resolution =0.99 x 0.99 mm 2 , scan time 14 min [50% NAV efficiency]) and a vessel targeted 3D SSFP MRA sequence (t-MRA) (TR=5.6 ms, TE-2.8 ms, 20 slices of 1.5 mm reconstructed slice thickness, in-plane resolution =0.99 x 0.99 mm 2 , scan time=7 min [50% NAV efficiency]). Subjective image quality (4-point scale) and objective image quality parameters including vessel sharpness, vessel diameter and CNR were calculated for WH-MRA and t-MRA. In patients, the accuracy for detection of stenosis larger than 50% was compared to the accuracy of X-ray coronary angiography (XA), which was considered the standard. Results: WH-MRA demonstrated good vessel visibility in healthy subjects (100%) whereas vessel visibility in patients was limited (78% in an 8 segment evaluation). Vessel sharpness was inferior to that of t-MRA in patients (37 vs. 42%) but equal in healthy subjects (42%). Vessel diameter did not differ significantly between WH-MRA and t-MRA. CNR was significantly reduced for WH-MRA (CNR 7.4 vs. 11.5). The diagnostic accuracy for the detection of CAD was comparable for both MRA approaches (85.5 vs. 86.2%). Conclusion: WH-MRA allows good coronary artery visualization in healthy subjects and patients and provides a simplified scanning procedure and advantages in 3D post-processing. Regarding image parameters and the detection of CAD, the results are comparable to those acquired with t-MRA. The major disadvantage remains the high number of diagnostically insufficient images. (orig.)

  19. Transposition of the great arteries - a phenotype associated with 16p11.2 duplications?

    Science.gov (United States)

    Karunanithi, Zarmiga; Vestergaard, Else Marie; Lauridsen, Mette H

    2017-12-26

    Genetic analyses of patients with transposition of the great arteries have identified rare copy number variations, suggesting that they may be significant to the aetiology of the disease. This paper reports the identification of a 16p11.2 microduplication, a variation that has yet to be reported in association with transposition of the great arteries. The 16p11.2 microduplication is associated with autism spectrum disorder and developmental delay, but with highly variable phenotypic effects. Autism and attention deficit disorders are observed more frequently in children with congenital heart disease than in the general population. Neonatal surgery is proposed as a risk factor, but as yet unidentified genetic abnormalities should also be taken into account. Thus, congenital heart abnormalities may constitute a part of the phenotypic spectrum associated with duplications at 16p11.2. We suggest chromosomal microarray be considered part of the diagnostic work-up in patients with transposition of the great arteries.

  20. Three Vessel Coronary Cameral Fistulae Associated with New Onset Atrial Fibrillation and Angina Pectoris

    Directory of Open Access Journals (Sweden)

    Murat Yuksel

    2014-01-01

    Full Text Available Coronary cameral fistulas are abnormal communications between a coronary artery and a heart chamber or a great vessel which are reported in less than 0.1% of patients undergoing diagnostic coronary angiography. All three major coronary arteries are even less frequently involved in fistula formation as it is the case in our patient. A 68-year-old woman was admitted to cardiology clinic with complaints of exertional dyspnea and angina for two years and a new onset palpitation. Standard 12-lead electrocardiogram revealed atrial fibrillation (AF with a ventricular rate of 114 beat/minute and accompanying T wave abnormalities and minimal ST-depression on lateral derivations. Transthoracic echocardiographic examination was normal except for diastolic dysfunction, minimally mitral regurgitation, and mild to moderate enlargement of the left atrium. Sinus rhythm was achieved by medical cardioversion with amiodarone infusion. Coronary angiography revealed diffuse and multiple coronary-left ventricle fistulas originating from the distal segments of both left and right coronary arterial systems without any stenosis in epicardial coronary arteries. The patient’s symptoms resolved almost completely with medical therapy. High volume shunts via coronary artery to left ventricular microfistulas may lead to increased volume overload and subsequent increase in end-diastolic pressure of the left ventricle and may cause left atrial enlargement.

  1. The Australian REEFREP System: A Coastal Vessel Traffic Information Service and Ship Reporting System for the Torres Strait Region and the Inner Route of the Great Barrier Reef

    Science.gov (United States)

    MacDonald, John C.

    The new Australian ship reporting system, identifier , will be the core component of a Vessel Traffic Information Service (VTIS) covering the Torres Strait region and the Great Barrier Reef (GBR). It is the first such system to be considered by the International Maritime Organization (IMO) under the terms of the new SOLAS 74 regulation v/8-1, which entered into force on 1 January 1996 and allows for ship reporting systems adopted by the Organization to be made mandatory for all, or certain categories of vessels.The REEFREP system, planned for implementation on 1 January 1997, extends for some 900 n.m. or about 1500 km along the Queensland coastline. It will be a VHF radio-based system with radars covering three selected focal points in the Torres Strait, off Cairns and in the southern approaches to the inner route. The system will provide a capability for a single Ship Reporting Centre to interact with shipping, enabling the provision of improved information on the presence, movements and patterns of shipping in the area and the ability to respond more quickly to an incident or pollution should this occur.An interesting feature and a major factor in the system design is the remoteness of most equipment sites and the limited infrastructure available to support communications and data transmission requiring the application of advanced technology and video transmission, solar power generation and software engineering skills of a high order.

  2. Extra-cardiac manifestations of adult congenital heart disease.

    Science.gov (United States)

    Gaeta, Stephen A; Ward, Cary; Krasuski, Richard A

    2016-10-01

    Advancement in correction or palliation of congenital cardiac lesions has greatly improved the lifespan of congenital heart disease patients, resulting in a rapidly growing adult congenital heart disease (ACHD) population. As this group has increased in number and age, emerging science has highlighted the systemic nature of ACHD. Providers caring for these patients are tasked with long-term management of multiple neurologic, pulmonary, hepatic, renal, and endocrine manifestations that arise as syndromic associations with congenital heart defects or as sequelae of primary structural or hemodynamic abnormalities. In this review, we outline the current understanding and recent research into these extra-cardiac manifestations. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Automated method for identification and artery-venous classification of vessel trees in retinal vessel networks.

    Science.gov (United States)

    Joshi, Vinayak S; Reinhardt, Joseph M; Garvin, Mona K; Abramoff, Michael D

    2014-01-01

    The separation of the retinal vessel network into distinct arterial and venous vessel trees is of high interest. We propose an automated method for identification and separation of retinal vessel trees in a retinal color image by converting a vessel segmentation image into a vessel segment map and identifying the individual vessel trees by graph search. Orientation, width, and intensity of each vessel segment are utilized to find the optimal graph of vessel segments. The separated vessel trees are labeled as primary vessel or branches. We utilize the separated vessel trees for arterial-venous (AV) classification, based on the color properties of the vessels in each tree graph. We applied our approach to a dataset of 50 fundus images from 50 subjects. The proposed method resulted in an accuracy of 91.44% correctly classified vessel pixels as either artery or vein. The accuracy of correctly classified major vessel segments was 96.42%.

  4. Quantitative assessment of thallium myocardial washout rate: Importance of peak heart rate and lung thallium uptake in defining normal values

    International Nuclear Information System (INIS)

    Nishimura, Tsunehiko; Uehara, Toshiisa; Hayashida, Kohei; Kozuka, Takahiro; Saito, Muneyasu; Sumiyoshi, Tetsuya; National Cardiovascular Center, Suita, Osaka

    1987-01-01

    Traditionally, the results of exercise thallium scintigraphy were interpreted by transient defect analysis using initial and delayed images. Recently, washout rate analysis has been used for the relative quantification of exercise thallium scintigraphy. A diffuse slow washout from all myocardial regions has been defined as the indicator of extensive coronary artery disease. However, slow washout has occasionally been observed in normal cases and in healthy myocardial segments which are not supplied by a stenosed artery in patients with single or double vessel disease. We evaluate the factors influencing washout rate in 100 normal patients and 63 patients with angina pectoris (33 cases of single vessel disease and 30 cases of double vessel disease). The washout rates were calculated using circumferential profile analysis. In normal patients, washout rate was closely related to peak heart rate (r=0.72) and inversely related to lung thallium uptake (r=-0.56). A diffuse slow washout was observed in seven (7%) of 100 normal patients, six (18%) of 33 cases of single vessel disease and eight (24%) of 30 cases of double vessel disease. The patients with diffuse slow washout showed significantly higher lung thallium uptake values and lower peak heart rates than those without diffuse slow washout (P<0.01). Thus, this false positive slow washout should be considered in the interpretation of quantitative exercise thallium scintigraphy. (orig.)

  5. The effect of relaxing music on heart rate and heart rate variability during ECG GATED-myocardial perfusion scintigraphy.

    Science.gov (United States)

    Tan, Yusuf Ziya; Ozdemir, Semra; Temiz, Ahmet; Celik, Fatmanur

    2015-05-01

    The positive changes in human behavior caused by relaxing music demonstrate the psychological effect of music on human body. A meta-analytical study has shown that relaxing music affects blood pressure and heart rate in coronary heart patients and cancer patients. The aim of our study is to research whether there is a significant effect on heart rate and heart rate variability due to listening to relaxing music during ECG GATED MPS imaging under gamma camera. The music group (n = 50 patients) could choose from 15 different musical types including folk music (no lyric). The other 50 patients were placed in a "no music group" and did not get headphones or any music. There was a statistically significant reduction in the heart rate of patients in the music group compared to those in the control group. Relaxing music provides great benefits to both patient and clinician. There is close relationship between relaxing music and health procedure, can use every area of the health noninvasiv, safe, cheap and is a method don't have side effect. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. sup 67 Ga imaging in the patients with infective endocarditis after surgery for congenital heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Kohata, Tohru; Ono, Yasuo; Kamiya, Tetsuro; Nishimura, Tsunehiko; Takamiya, Makoto; Yagihara, Toshikatsu [National Cardiovascular Center, Suita, Osaka (Japan)

    1991-11-01

    {sup 67}Ga imaging was performed in sixteen patients (age: 8 m.-18 y.) who had persistent fever and positive acute phase reactants after surgery for congenital heart disease. Abnormal uptake of {sup 67}Ga over the heart and the lungs was evaluated with a computer. Abnormal uptake of {sup 67}Ga was observed in seven patients. Of them, three showed it in the area of peripheral pulmonary artery and the other four showed it in the area of artificial vessels for pulmonary artery reconstruction. In six patients with positive blood cultures, five showed abnormal uptake of {sup 67}Ga and in ten patients with negative blood cultures, two showed it. Vegetation was detected with 2D-echocardiography in four patients and all of them showed abnormal uptake of {sup 67}Ga, while in 12 patients without vegetation three showed it. In conclusion, {sup 67}Ga imaging was useful to detect the foci of infective endocarditis or pulmonary embolism caused by the vegetation in infective endocarditis in the patients after surgery for congenital heart disease, especially in the peripheral pulmonary arteries and artificial vessels which could not be detected with 2D-echo. (author).

  7. Pressure vessel for nuclear reactor plant consisting of several pre-stressed cast pressure vessels

    International Nuclear Information System (INIS)

    Bodmann, E.

    1984-01-01

    Several cylindrical pressure vessel components made of pressure castings are arranged on a sector of a circle around the cylindrical cast pressure vessel for accommodating the helium cooled HTR. Each component pressure vessel is connected to the reactor vessel by a horizontal gas duct. The contact surfaces between reactor and component pressure vessel are in one plane. In the spaces between the individual component pressure vessels, there are supporting blocks made of cast iron, which are hollow and also have flat surfaces. With the reactor vessel and the component pressure vessels they form a disc-shaped connecting part below and above the gas ducts. (orig./PW)

  8. Void nucleation by the helium atoms during lifetime of reactor pressure vessel

    International Nuclear Information System (INIS)

    Rahman, F.A.

    1984-01-01

    Void formation and growth has a great influence on the reactor pressure vessel steels during its lifetime and during post-irradiation annealing to increase its life. The present investigation aimed at the fact that if one can prevent void nucleation, accordingly one would not wary about void formation and growth. From that concept a model for helium production by transmutation reaction and corresponding swelling under irradiation conditions for several number of steels have been developed. This was done for recommending a steel type that can oppose such a phenomena. In the same time the present investigation gives a procedure utilizing such phenomena for checking the validity of pressure vessel steel used in the NPP

  9. Verification of rubidium-82 for heart studies

    International Nuclear Information System (INIS)

    Budinger, T.F.; Yano, Y.; Twitchell, J.A.; Brennan, K.M.

    1985-01-01

    Whereas 82 Rb has been shown to reflect heart blood-flow under normal circumstances and has the great benefit of being available from a noncyclotron source, there remains a question with regard to the physiology of rubidium transport into the heart muscle. The fraction of the amount of the rubidium tracer that goes into the heart varies with flow, and, unfortunately, the amount that accumulates in the muscle will not therefore be proportional to flow. Over the past three years, the authors have re-evaluated this question and determined that the uptake of rubidium in the myocardium follows a simple model of conservation of mass wherein the amount that is present is equal to the product of flow times extraction

  10. Reinforcement versus fluidization in cytoskeletal mechanoresponsiveness

    NARCIS (Netherlands)

    Krishnan, R.; Park, C.Y.; Lin, Y.C.; Mead, J.; Jaspers, R.T.; Trepat, X.; Lenormand, G.; Tambe, D.; Smolensky, A.V.; Knoll, A.H.; Butler, J.P.; Fredberg, J.J.

    2009-01-01

    Every adherent eukaryotic cell exerts appreciable traction forces upon its substrate. Moreover, every resident cell within the heart, great vessels, bladder, gut or lung routinely experiences large periodic stretches. As an acute response to such stretches the cytoskeleton can stiffen, increase

  11. Probabilistic retinal vessel segmentation

    Science.gov (United States)

    Wu, Chang-Hua; Agam, Gady

    2007-03-01

    Optic fundus assessment is widely used for diagnosing vascular and non-vascular pathology. Inspection of the retinal vasculature may reveal hypertension, diabetes, arteriosclerosis, cardiovascular disease and stroke. Due to various imaging conditions retinal images may be degraded. Consequently, the enhancement of such images and vessels in them is an important task with direct clinical applications. We propose a novel technique for vessel enhancement in retinal images that is capable of enhancing vessel junctions in addition to linear vessel segments. This is an extension of vessel filters we have previously developed for vessel enhancement in thoracic CT scans. The proposed approach is based on probabilistic models which can discern vessels and junctions. Evaluation shows the proposed filter is better than several known techniques and is comparable to the state of the art when evaluated on a standard dataset. A ridge-based vessel tracking process is applied on the enhanced image to demonstrate the effectiveness of the enhancement filter.

  12. Leonardo da Vinci's studies of the heart.

    Science.gov (United States)

    Shoja, Mohammadali M; Agutter, Paul S; Loukas, Marios; Benninger, Brion; Shokouhi, Ghaffar; Namdar, Husain; Ghabili, Kamyar; Khalili, Majid; Tubbs, R Shane

    2013-08-20

    Leonardo da Vinci's detailed drawings are justly celebrated; however, less well known are his accounts of the structures and functions of the organs. In this paper, we focus on his illustrations of the heart, his conjectures about heart and blood vessel function, his experiments on model systems to test those conjectures, and his unprecedented conclusions about the way in which the cardiovascular system operates. In particular, da Vinci seems to have been the first to recognize that the heart is a muscle and that systole is the active phase of the pump. He also seems to have understood the functions of the auricles and pulmonary veins, identified the relationship between the cardiac cycle and the pulse, and explained the hemodynamic mechanism of valve opening and closure. He also described anatomical variations and changes in structure and function that occurred with age. We outline da Vinci's varied career and suggest ways in which his personality, experience, skills and intellectual heritage contributed to these advances in understanding. We also consider his influence on later studies in anatomy and physiology. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  13. Intravital two-photon microscopy of immune cell dynamics in corneal lymphatic vessels.

    Directory of Open Access Journals (Sweden)

    Philipp Steven

    Full Text Available BACKGROUND: The role of lymphatic vessels in tissue and organ transplantation as well as in tumor growth and metastasis has drawn great attention in recent years. METHODOLOGY/PRINCIPAL FINDINGS: We now developed a novel method using non-invasive two-photon microscopy to simultaneously visualize and track specifically stained lymphatic vessels and autofluorescent adjacent tissues such as collagen fibrils, blood vessels and immune cells in the mouse model of corneal neovascularization in vivo. The mouse cornea serves as an ideal tissue for this technique due to its easy accessibility and its inducible and modifiable state of pathological hem- and lymphvascularization. Neovascularization was induced by suture placement in corneas of Balb/C mice. Two weeks after treatment, lymphatic vessels were stained intravital by intrastromal injection of a fluorescently labeled LYVE-1 antibody and the corneas were evaluated in vivo by two-photon microscopy (TPM. Intravital TPM was performed at 710 nm and 826 nm excitation wavelengths to detect immunofluorescence and tissue autofluorescence using a custom made animal holder. Corneas were then harvested, fixed and analyzed by histology. Time lapse imaging demonstrated the first in vivo evidence of immune cell migration into lymphatic vessels and luminal transport of individual cells. Cells immigrated within 1-5.5 min into the vessel lumen. Mean velocities of intrastromal corneal immune cells were around 9 µm/min and therefore comparable to those of T-cells and macrophages in other mucosal surfaces. CONCLUSIONS: To our knowledge we here demonstrate for the first time the intravital real-time transmigration of immune cells into lymphatic vessels. Overall this study demonstrates the valuable use of intravital autofluorescence two-photon microscopy in the model of suture-induced corneal vascularizations to study interactions of immune and subsequently tumor cells with lymphatic vessels under close as possible

  14. Variation and treatment of vessels in laparoscopic right hemicolectomy.

    Science.gov (United States)

    Ye, Kai; Lin, Jianan; Sun, Yafeng; Wu, Yiyang; Xu, Jianhua; He, Songbing

    2018-03-01

    With the introduction of complete mesocolic excision (CME) and the application of laparoscopic technique, surgery for colon cancer has become more standardized and the curative effect has improved [1]. The key points in laparoscopic right hemicolectomy are high ligation of main vessels and root dissection of lymph nodes. The wide range of variations in vascular architecture and intraoperative bleeding are common causes of prolonged surgical time, wound hemorrhage, and even transfer to the opening operation. The superior mesenteric vein (SMV) is the most important anatomical landmark in CME for the right colon, and guides all the steps of lymph node dissection. The SMV appears as a pale blue bulge on laparoscopy, which enables accurate positioning. The ileocolic vessel pedicle is relatively constant and facilitates accurate positioning. The intersection of the ileocolic vessel pedicle and the SMV is the optimal starting point in laparoscopic right hemicolectomy using a medial-to-lateral approach. A sheath with an avascular plane can be reached after opening the SMV vascular sheath, which results in less bleeding and enables vascular root and thorough lymph node dissection. The first step is to manage the ileocolic vessels. The ileocolic artery (ICA) is located anterior to the ileocolic vein (ICV) for about one-third of the incidence. The ileocolic vessels are relatively long and are easy to work with. In the vast majority of cases, the ICV drains into the SMV, and into the gastrocolic trunk (GCT) in about 2.5% of cases. The reported incidence of a right colic artery (RCA) is controversial; the RCA is absent in about 50% of cases and often crosses the SMV. The right colic vein (RCV) usually drains into the GCT, but sometimes drains directly into the SMV. The middle colic vessels have great variability and a close anatomical relationship with the pancreas, duodenum, and GCT. Moreover, the transverse colon and mesentery are long, and root positioning and processing of

  15. Shock loading of reactor vessel following hypothetical core disruptive accident

    International Nuclear Information System (INIS)

    Srinivas, G.; Doshi, J.B.

    1990-01-01

    Hypothetical Core Disruptive Accident (HCDA) has been historically considered as the maximum credible accident in Fast Breeder Reactor systems. Environmental consequences of such an accident depends to a great extent on the ability of the reactor vessel to maintain integrity during the shock loading following an HCDA. In the present paper, a computational model of the reactor core and the surrounding coolant with a free surface is numerical technique. The equations for conservation of mass, momentum and energy along with an equation of state are considered in two dimensional cylindrical geometry. The reactor core at the end of HCDA is taken as a bubble of hot, vaporized fuel at high temperature and pressure, formed at the center of the reactor vessel and expanding against the surrounding liquid sodium coolant. The free surface of sodium at the top of the vessel and the movement of the core bubble-liquid coolant interface are tracked by Marker and Cell (MAC) procedure. The results are obtained for the transient pressure at the vessel wall and also for the loading on the roof plug by the impact of the slug of liquid sodium. The computer code developed is validated against a benchmark experiment chosen to be ISPRA experiment reported in literature. The computer code is next applied to predict the loading on the Indian Prototype Fast Breeder Reactor (PFBR) being developed at Kalpakkam

  16. A Novel Through Capacity Model for One-way Channel Based on Characteristics of the Vessel Traffic Flow

    Directory of Open Access Journals (Sweden)

    Yuanyuan Nie

    2017-09-01

    Full Text Available Vessel traffic flow is a key parameter for channel-through capacity and is of great significance to vessel traffic management, channel and port design and navigational risk evaluation. Based on the study of parameters of characteristics of vessel traffic flow related to channel-through capacity, this paper puts forward a brand-new mathematical model for one-way channel-through capacity in which parameters of channel length, vessel arrival rate and velocity difference in different vessels are involved and a theoretical calculating mechanism for the channel-through capacity is provided. In order to verify availability and reliability of the model, extensive simulation studies have been carried out and based on the historical AIS data, an analytical case study on the Xiazhimen Channel validating the proposed model is presented. Both simulation studies and the case study show that the proposed model is valid and all relative parameters can be readjusted and optimized to further improve the channel-through capacity. Thus, all studies demonstrate that the model is valuable for channel design and vessel management.

  17. ITER vacuum vessel design and electromagnetic analysis on in-vessel components

    International Nuclear Information System (INIS)

    Ioki, K.; Johnson, G.; Shimizu, K.; Williamson, D.; Iizuka, T.

    1995-01-01

    Major functional requirements for the vacuum vessel are to provide the first safety barrier and to support electromagnetic loads due to plasma disruptions and vertical displacement events, and to withstand plausible accidents without losing confinement. A double wall structure concept has been developed for the vacuum vessel due to its beneficial characteristics from the viewpoints of structural integrity and electrical continuity. An electromagnetic analysis of the blanket modules and the vacuum vessel has been performed to investigate force distributions on in-vessel components. According to the vertical displacement events (VDE) scenario, which assumes a critical q-value of 1.5, the total downward vertical force, induced by coupling between the eddy current and external fields, is about 110 MN. We have performed a stress analysis for the vacuum vessel using the VDE disruption forces acting on the blankets, and a maximum stress intensity of 112 MPa was obtained in the vicinity of the lower support of the vessel. (orig.)

  18. An automated vessel segmentation of retinal images using multiscale vesselness

    International Nuclear Information System (INIS)

    Ben Abdallah, M.; Malek, J.; Tourki, R.; Krissian, K.

    2011-01-01

    The ocular fundus image can provide information on pathological changes caused by local ocular diseases and early signs of certain systemic diseases, such as diabetes and hypertension. Automated analysis and interpretation of fundus images has become a necessary and important diagnostic procedure in ophthalmology. The extraction of blood vessels from retinal images is an important and challenging task in medical analysis and diagnosis. In this paper, we introduce an implementation of the anisotropic diffusion which allows reducing the noise and better preserving small structures like vessels in 2D images. A vessel detection filter, based on a multi-scale vesselness function, is then applied to enhance vascular structures.

  19. Research vessels

    Digital Repository Service at National Institute of Oceanography (India)

    Rao, P.S.

    The role of the research vessels as a tool for marine research and exploration is very important. Technical requirements of a suitable vessel and the laboratories needed on board are discussed. The history and the research work carried out...

  20. Safety analysis of nuclear containment vessels subjected to strong earthquakes and subsequent tsunamis

    Directory of Open Access Journals (Sweden)

    Feng Lin

    2017-08-01

    Full Text Available Nuclear power plants under expansion and under construction in China are mostly located in coastal areas, which means they are at risk of suffering strong earthquakes and subsequent tsunamis. This paper presents a safety analysis for a new reinforced concrete containment vessel in such events. A finite element method-based model was built, verified, and first used to understand the seismic performance of the containment vessel under earthquakes with increased intensities. Then, the model was used to assess the safety performance of the containment vessel subject to an earthquake with peak ground acceleration (PGA of 0.56g and subsequent tsunamis with increased inundation depths, similar to the 2011 Great East earthquake and tsunami in Japan. Results indicated that the containment vessel reached Limit State I (concrete cracking and Limit State II (concrete crushing when the PGAs were in a range of 0.8–1.1g and 1.2–1.7g, respectively. The containment vessel reached Limit State I with a tsunami inundation depth of 10 m after suffering an earthquake with a PGA of 0.56g. A site-specific hazard assessment was conducted to consider the likelihood of tsunami sources.

  1. Supervised retinal vessel segmentation from color fundus images based on matched filtering and AdaBoost classifier.

    Directory of Open Access Journals (Sweden)

    Nogol Memari

    Full Text Available The structure and appearance of the blood vessel network in retinal fundus images is an essential part of diagnosing various problems associated with the eyes, such as diabetes and hypertension. In this paper, an automatic retinal vessel segmentation method utilizing matched filter techniques coupled with an AdaBoost classifier is proposed. The fundus image is enhanced using morphological operations, the contrast is increased using contrast limited adaptive histogram equalization (CLAHE method and the inhomogeneity is corrected using Retinex approach. Then, the blood vessels are enhanced using a combination of B-COSFIRE and Frangi matched filters. From this preprocessed image, different statistical features are computed on a pixel-wise basis and used in an AdaBoost classifier to extract the blood vessel network inside the image. Finally, the segmented images are postprocessed to remove the misclassified pixels and regions. The proposed method was validated using publicly accessible Digital Retinal Images for Vessel Extraction (DRIVE, Structured Analysis of the Retina (STARE and Child Heart and Health Study in England (CHASE_DB1 datasets commonly used for determining the accuracy of retinal vessel segmentation methods. The accuracy of the proposed segmentation method was comparable to other state of the art methods while being very close to the manual segmentation provided by the second human observer with an average accuracy of 0.972, 0.951 and 0.948 in DRIVE, STARE and CHASE_DB1 datasets, respectively.

  2. Cardioscopic tricuspid valve repair in a beating ovine heart.

    Science.gov (United States)

    Umakanthan, Ramanan; Ghanta, Ravi K; Rangaraj, Aravind T; Lee, Lawrence S; Laurence, Rita G; Fox, John A; Mihaljevic, Tomislav; Bolman, Ralph M; Cohn, Lawrence H; Chen, Frederick Y

    2009-04-01

    Open heart surgery is commonly associated with cardiopulmonary bypass and cardioplegic arrest. The attendant risks of cardiopulmonary bypass may be prohibitive in high-risk patients. We present a novel endoscopic technique of performing tricuspid valve repair without cardiopulmonary bypass in a beating ovine heart. Six sheep underwent sternotomy and creation of a right heart shunt to eliminate right atrial and right ventricular blood for clear visualization. The superior vena cava, inferior vena cava, pulmonary artery, and coronary sinus were cannulated, and the blood flow from these vessels was shunted into the pulmonary artery via a roller pump. The posterior leaflet of the tricuspid valve was partially excised to create tricuspid regurgitation, which was confirmed by Doppler echocardiography. A 7.0-mm fiberoptic videoscope was inserted into the right atrium to visualize the tricuspid valve. Under cardioscopic vision, an endoscopic needle driver was inserted into the right atrium, and a concentric stitch was placed along the posterior annulus to bicuspidize the tricuspid valve. Doppler echocardiography confirmed reduction of tricuspid regurgitation. All animals successfully underwent and tolerated the surgical procedure. The right heart shunt generated a bloodless field, facilitating cardioscopic tricuspid valve visualization. The endoscopic stitch resulted in annular plication and functional tricuspid valve bicuspidization, significantly reducing the degree of tricuspid regurgitation. Cardioscopy enables less invasive, beating-heart tricuspid valve surgery in an ovine model. This technique may be useful in performing right heart surgery without cardiopulmonary bypass in high-risk patients.

  3. Integration of ITER in-vessel diagnostic components in the vacuum vessel

    International Nuclear Information System (INIS)

    Encheva, A.; Bertalot, L.; Macklin, B.; Vayakis, G.; Walker, C.

    2009-01-01

    The integration of ITER in-vessel diagnostic components is an important engineering activity. The positioning of the diagnostic components must correlate not only with their functional specifications but also with the design of the major parts of ITER torus, in particular the vacuum vessel, blanket modules, blanket manifolds, divertor, and port plugs, some of which are not yet finally designed. Moreover, the recently introduced Edge Localised Mode (ELM)/Vertical Stability (VS) coils mounted on the vacuum vessel inner wall call for not only more than a simple review of the engineering design settled down for several years now, but also for a change in the in-vessel distribution of the diagnostic components and their full impact has yet to be determined. Meanwhile, the procurement arrangement (a document defining roles and responsibilities of ITER Organization and Domestic Agency(s) (DAs) for each in-kind procurement including technical scope of work, quality assurance requirements, schedule, administrative matters) for the vacuum vessel must be finalized. These make the interface process even more challenging in terms of meeting the vacuum vessel (VV) procurement arrangement's deadline. The process of planning the installation of all the ITER diagnostics and integrating their installation into the ITER Integrated Project Schedule (IPS) is now underway. This paper covers the progress made recently on updating and issuing the interfaces of the in-vessel diagnostic components with the vacuum vessel, outlines the requirements for their attachment and summarises the installation sequence.

  4. Micro-angiographic system using synchrotron radiation and conventional x-ray source for visualizing angiogenic vessels induced by cardiovascular regeneration therapy

    International Nuclear Information System (INIS)

    Mori, H.; Chiku, M.; Nishigami, K.; Tanaka, E.; Kimura, K.; Kawai, T.; Suzuki, K.; Mochizuki, R.; Okawa, Y.

    2004-01-01

    Therapeutic angiogenesis improved critical limb and myocardial ischemia in human, however, angiogenic vessels were not visualized well by conventional angiography, because of its limited spatial resolution of 200 μm. Recently, synchrotron radiation system characterized by high brightness, monochromatic and collimated nature revealed the micro-vessels of heart and lower limb in situ. We developed also an in-house microangiographic system with a relatively low cost. Limb ischemia models were made by ligature of femoral artery and treated by angiogenic growth factor genes and so on. One month after the treatment, we evaluated collateral micro-vessels by using the conventional and micro-angiographic systems. The approach was left femoral artery, and catheter was located in abdominal aorta. Iodine contrast (300 mg/ml) was injected 5 ml by 3 ml/sec with auto-injection system. The imaging was recorded by digital source in 1000 x 1000 pixels. The micro-angiographic system could detect the micro-vessels more precisely than conventional angiographic system and evaluate their function. (author)

  5. FFTF and CRBRP reactor vessels

    International Nuclear Information System (INIS)

    Morgan, R.E.

    1977-01-01

    The Fast Flux Test Facility (FFTF) reactor vessel and the Clinch River Breeder Reactor Plant (CRBRP) reactor vessel each serve to enclose a fast spectrum reactor core, contain the sodium coolant, and provide support and positioning for the closure head and internal structure. Each vessel is located in its reactor cavity and is protected by a guard vessel which would ensure continued decay heat removal capability should a major system leak develop. Although the two plants have significantly different thermal power ratings, 400 megawatts for FFTF and 975 megawatts for CRBRP, the two reactor vessels are comparable in size, the CRBRP vessel being approximately 28% longer than the FFTF vessel. The FFTF vessel diameter was controlled by the space required for the three individual In-Vessel Handling Machines and Instrument Trees. Utilization of the triple rotating plug scheme for CRBRP refueling enables packaging of the larger CRBRP core in a vessel the same diameter as the FFTF vessel

  6. Stem cell markers in the heart of the human newborn

    Directory of Open Access Journals (Sweden)

    Armando Faa

    2016-07-01

    Full Text Available The identification of cardiac progenitor cells in mammals raises the possibility that the human heart contains a population of stem cells capable of generating cardiomyocytes and coronary vessels. Several recent studies now show that the different cell types that characterize the adult human heart arise from a common ancestor. Human cardiac stem cells differentiate into cardiomyocytes, and, in lesser extent, into smooth muscle and endothelial cells. The characterization of human cardiac stem cells (CSCs has important clinical implications. In recent years, CD117 (c-kit has been reported to mark a subtype of stem/progenitor cells in the human heart, with stem cell-like properties, including the ability to self-renewal and clonogenicity multipotentiality. Proceedings of the 2nd International Course on Perinatal Pathology (part of the 11th International Workshop on Neonatology · October 26th-31st, 2015 · Cagliari (Italy · October 31st, 2015 · Stem cells: present and future Guest Editors: Gavino Faa, Vassilios Fanos, Antonio Giordano

  7. Effects of low upper shelf fracture toughness on reactor vessel integrity during pressurized thermal shock events

    International Nuclear Information System (INIS)

    Bamford, W.H.; Heinecke, C.C.; Balkey, K.R.

    1988-01-01

    For the past decade, significant attention has been focused on the subject of nuclear rector vessel integrity during pressurized thermal shock (PTS) events. The issue of low upper shelf fracture toughness at operating temperatures has been a consideration for some reactor vessel materials since the early 1970's. Deterministic and probabilistic fracture mechanics sensitivity studies have been completed to evaluate the interaction between the PTS and lower upper shelf toughness issues that result from neutron embrittlement of the critical beltline region materials. This paper presents the results of these studies to show the interdependency of these fracture considerations in certain instances and to identify parameters that need to be carefully treated in reactor vessel integrity evaluations for these subjects. This issue is of great importance to those vessels which have low upper shelf toughness, both for demonstrating safety during the original design life and in life extension assessments

  8. Tumor Blood Vessel Dynamics

    Science.gov (United States)

    Munn, Lance

    2009-11-01

    ``Normalization'' of tumor blood vessels has shown promise to improve the efficacy of chemotherapeutics. In theory, anti-angiogenic drugs targeting endothelial VEGF signaling can improve vessel network structure and function, enhancing the transport of subsequent cytotoxic drugs to cancer cells. In practice, the effects are unpredictable, with varying levels of success. The predominant effects of anti-VEGF therapies are decreased vessel leakiness (hydraulic conductivity), decreased vessel diameters and pruning of the immature vessel network. It is thought that each of these can influence perfusion of the vessel network, inducing flow in regions that were previously sluggish or stagnant. Unfortunately, when anti-VEGF therapies affect vessel structure and function, the changes are dynamic and overlapping in time, and it has been difficult to identify a consistent and predictable normalization ``window'' during which perfusion and subsequent drug delivery is optimal. This is largely due to the non-linearity in the system, and the inability to distinguish the effects of decreased vessel leakiness from those due to network structural changes in clinical trials or animal studies. We have developed a mathematical model to calculate blood flow in complex tumor networks imaged by two-photon microscopy. The model incorporates the necessary and sufficient components for addressing the problem of normalization of tumor vasculature: i) lattice-Boltzmann calculations of the full flow field within the vasculature and within the tissue, ii) diffusion and convection of soluble species such as oxygen or drugs within vessels and the tissue domain, iii) distinct and spatially-resolved vessel hydraulic conductivities and permeabilities for each species, iv) erythrocyte particles advecting in the flow and delivering oxygen with real oxygen release kinetics, v) shear stress-mediated vascular remodeling. This model, guided by multi-parameter intravital imaging of tumor vessel structure

  9. Coronary artery assessment using self-navigated free-breathing radial whole-heart magnetic resonance angiography in patients with congenital heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Albrecht, Moritz H. [Medical University of South Carolina, Department of Radiology and Radiological Science, Division of Cardiovascular Imaging, Charleston, SC (United States); University Hospital Frankfurt, Department of Diagnostic and Interventional Radiology, Frankfurt (Germany); Varga-Szemes, Akos; Schoepf, U.J.; Xu, Jiaqian; Jin, Kwang-Nam; Hlavacek, Anthony M.; Chowdhury, Shahryar M.; Suranyi, Pal; Tesche, Christian; De Cecco, Carlo N.; Nutting, Arni [Medical University of South Carolina, Department of Radiology and Radiological Science, Division of Cardiovascular Imaging, Charleston, SC (United States); Apfaltrer, Georg [Medical University of South Carolina, Department of Radiology and Radiological Science, Division of Cardiovascular Imaging, Charleston, SC (United States); University Hospital Graz, Department of Radiology, Graz (Austria); Piccini, Davide [University Hospital of Lausanne (CHUV), Department of Radiology, Centre for Biomedical Imaging (CIBM), Lausanne (Switzerland); Siemens Healthcare, IM BM PI, Advanced Clinical Imaging Technology, Lausanne (Switzerland); Stuber, Matthias; Ginami, Giulia [University Hospital of Lausanne (CHUV), Department of Radiology, Centre for Biomedical Imaging (CIBM), Lausanne (Switzerland); Vogl, Thomas J. [University Hospital Frankfurt, Department of Diagnostic and Interventional Radiology, Frankfurt (Germany)

    2018-03-15

    To evaluate a self-navigated free-breathing three-dimensional (SNFB3D) radial whole-heart MRA technique for assessment of main coronary arteries (CAs) and side branches in patients with congenital heart disease (CHD). SNFB3D-MRA datasets of 109 patients (20.1±11.8 years) were included. Three readers assessed the depiction of CA segments, diagnostic confidence in determining CA dominance, overall image quality and the ability to freeze cardiac and respiratory motion. Vessel sharpness was quantitatively measured. The percentages of cases with excellent CA depiction were as follows (mean score): left main, 92.6 % (1.92); left anterior descending (LAD), 88.3 % (1.88); right (RCA), 87.8 % (1.85); left circumflex, 82.8 % (1.82); posterior descending, 50.2 % (1.50) and first diagonal, 39.8 % (1.39). High diagnostic confidence for the assessment of CA dominance was achieved in 56.2 % of MRA examinations (mean score, 1.56). Cardiac motion freezing (mean score, 2.18; Pearson's r=0.73, P<0.029) affected image quality more than respiratory motion freezing (mean score, 2.20; r=0.58, P<0.029). Mean quantitative vessel sharpness of the internal thoracic artery, RCA and LAD were 53.1, 52.5 and 48.7 %, respectively. Most SNFB3D-MRA examinations allow for excellent depiction of the main CAs in young CHD patients; visualisation of side branches remains limited. (orig.)

  10. Finite element analyses for design evaluation of biodegradable magnesium alloy stents in arterial vessels

    Energy Technology Data Exchange (ETDEWEB)

    Wu Wei [Laboratory of Biological Structure Mechanics, Structural Engineering Department, Politecnico di Milano, Piazza Leonardo da Vinci, 32, 20133 Milan (Italy); Gastaldi, Dario, E-mail: dario.gastaldi@polimi.it [Laboratory of Biological Structure Mechanics, Structural Engineering Department, Politecnico di Milano, Piazza Leonardo da Vinci, 32, 20133 Milan (Italy); Yang Ke; Tan Lili [Division of Specialized Materials and Devices, Institute of Metal Research, Chinese Academy of Sciences, Shenyang (China); Petrini, Lorenza; Migliavacca, Francesco [Laboratory of Biological Structure Mechanics, Structural Engineering Department, Politecnico di Milano, Piazza Leonardo da Vinci, 32, 20133 Milan (Italy)

    2011-12-15

    Biodegradable magnesium alloy stents (MAS) can provide a great benefit for diseased vessels and avoid the long-term incompatible interactions between vessels and permanent stent platforms. However, the existing MAS showed insufficient scaffolding to the target vessels due to short degradation time. In this study, a three dimensional finite element model combined with a degradable material model of AZ31 (Al 0.03, Zn 0.01, Mn 0.002 and Mg balance, mass percentage) was applied to three different MAS designs including an already implanted stent (Stent A), an optimized design (Stent B) and a patented stent design (Stent C). One ring of each design was implanted through a simulation in a vessel model then degraded with the changing interaction between outer stent surface and the vessel. Results showed that a proper stent design (Stent B) can lead to an increase of nearly 120% in half normalized recoil time of the vessel compared to the Stent A; moreover, the expectation that the MAS design, with more mass and optimized mechanical properties, can increase scaffolding time was verified numerically. The Stent C has more materials than Stent B; however, it only increased the half normalized recoil time of the vessel by nearly 50% compared to the Stent A because of much higher stress concentration than that of Stent B. The 3D model can provide a convenient design and testing tool for novel magnesium alloy stents.

  11. Finite element analyses for design evaluation of biodegradable magnesium alloy stents in arterial vessels

    International Nuclear Information System (INIS)

    Wu Wei; Gastaldi, Dario; Yang Ke; Tan Lili; Petrini, Lorenza; Migliavacca, Francesco

    2011-01-01

    Biodegradable magnesium alloy stents (MAS) can provide a great benefit for diseased vessels and avoid the long-term incompatible interactions between vessels and permanent stent platforms. However, the existing MAS showed insufficient scaffolding to the target vessels due to short degradation time. In this study, a three dimensional finite element model combined with a degradable material model of AZ31 (Al 0.03, Zn 0.01, Mn 0.002 and Mg balance, mass percentage) was applied to three different MAS designs including an already implanted stent (Stent A), an optimized design (Stent B) and a patented stent design (Stent C). One ring of each design was implanted through a simulation in a vessel model then degraded with the changing interaction between outer stent surface and the vessel. Results showed that a proper stent design (Stent B) can lead to an increase of nearly 120% in half normalized recoil time of the vessel compared to the Stent A; moreover, the expectation that the MAS design, with more mass and optimized mechanical properties, can increase scaffolding time was verified numerically. The Stent C has more materials than Stent B; however, it only increased the half normalized recoil time of the vessel by nearly 50% compared to the Stent A because of much higher stress concentration than that of Stent B. The 3D model can provide a convenient design and testing tool for novel magnesium alloy stents.

  12. Multiple Coronary Chamber Microfistulas or Persistent Thebesian Vessels?

    Directory of Open Access Journals (Sweden)

    Cernica Daniel

    2017-09-01

    Full Text Available Coronary fistulas are rare, not gender-specific congenital conditions, consisting of communications between the coronary arteries and either another coronary vessel or a cardiac chamber. In contrast to large fistulas, small fistulas, named “minimae cordis veneae” or the Thebesius venous system, are draining into heart chambers and form a vascular network in the cardiac lumen. In this article, we present the case of a 72-year-old female with a significant history of cardiovascular disease, admitted to our clinic because of rest dyspnea, fatigue, and minimal chest pain. The 12-lead electrocardiogram showed a trifascicular block (a second-degree atrioventricular block Mobitz II, associated with a right bundle branch block and left anterior fascicle block and negative T waves in DII, DIII, aVF, V4–V6 leads. An invasive coronary angiography was performed, which revealed no significant atherosclerotic lesions. However, a persistent capillary blush was present at the apex site of the left ventricular chamber, draining from the distal segments of both the anterior descending coronary artery and the posterior interventricular coronary artery. The intramural vascular network generating a left ventricle angiogram image of this kind was suggestive for persistent Thebesian vessels connecting the two coronaries with the left ventricular chamber.

  13. The TPX vacuum vessel and in-vessel components

    International Nuclear Information System (INIS)

    Heitzenroeder, P.; Bialek, J.; Ellis, R.; Kessel, C.; Liew, S.

    1994-01-01

    The Tokamak Physics Experiment (TPX) is a superconducting tokamak with double-null diverters. TPX is designed for 1,000-second discharges with the capability of being upgraded to steady state operation. High neutron yields resulting from the long duration discharges require that special consideration be given to materials and maintainability. A unique feature of the TPX is the use of a low activation, titanium alloy vacuum vessel. Double-wall vessel construction is used since it offers an efficient solution for shielding, bakeout and cooling. Contained within the vacuum vessel are the passive coil system, Plasma Facing Components (PFCs), magnetic diagnostics, and the internal control coils. All PFCs utilize carbon-carbon composites for exposed surfaces

  14. Severe pregnancy-induced deterioration of truncal valve regurgitation in an adolescent patient with repaired truncus arteriosus

    NARCIS (Netherlands)

    Hoendermis, Elke S.; Drenthen, Willem; Sollie, Krystyna M.; Berger, Rolf M. F.

    2008-01-01

    Truncus arteriosus, a rare and complex congenital heart disease, is hallmarked by a single great vessel ( truncus) that arises over a large ventricular septal defect and provides both the pulmonary and systemic circulation. Pregnancy reports after repair for truncus arteriosus are scarce. Therefore,

  15. Thermo-mechanical behaviour of FBTR reactor vessel due to natural convection in cover gas space

    International Nuclear Information System (INIS)

    Srinivasan, G.; Varadarajan, S.; Kapoor, R.P.

    1988-01-01

    Fast Breeder Test Reactor is a 40 MW(t), loop type sodium cooled reactor, similar in design to Rapsodie. The Reactor Assembly, which is the heart of FBTR, comprises the Reactor Vessel (RV) housed in a safety vessel within a concrete cell (A1 Cell). The RV which supports the core is shielded at the top by two rotatable plugs which are stacked with layers of borated graphite and steel. The smaller plug (SRP), is mounted excentric to the larger one (LRP). A nominal annular gap of 16 mm is provided between RV and LRP and between LRP and SRP to enable free rotation of the plugs. Stainless Steel insulation is fixed inside the steel vessel, to avoid overheating of the A1 Cell concrete. The core is supported by the Grid Plate (GP), bolted to the RV. During preheating, sodium charging and isothermal runs upto 350 0 C, temperature asymmetries were noticed in the reactor vessel wall in the cover gas space. This was attributable to convection currents in the annulus between RV and LRP. The asymmetries also resulted in a lateral shift of the grid plate. This paper discusses our experience in suppressing these convection currents, and minimising the grid plate shift

  16. Multidetector-row computed tomography coronary angiography. Optimization of image reconstruction phase according to the heart rate

    International Nuclear Information System (INIS)

    Nagatani, Yukihiro; Takahashi, Masashi; Takazakura, Ryutaro; Nitta, Norihisa; Murata, Kiyoshi; Ushio, Noritoshi; Matsuo, Shinro; Yamamoto, Takashi; Horie, Minoru

    2007-01-01

    The purpose of this study was to optimize the image reconstruction phase of multidetector-row computed tomography (MDCT) coronary angiography according to the heart rate is crucial. Scan data were reconstructed for 10 different phases in 58 sequential patients who under went 8-row cardiac MDCT. The obtained images were scored and compared in terms of motion artifacts and visibility of the vessels, and moreover, electrocardiogram (ECG) record-based evaluations were added for clarification of the temporal relationships among these 10 phases. In the cases with lower heart rates ( 65 beats/mm), they were obtained in the late systolic period. As the heart rate increased, the optimal image reconstruction phase changed from mid diastole to late systole. However, it is recommended to try to decrease the heart rate of patients before data acquisition. (author)

  17. Thermal effect on heart rate and hemodynamics in vitelline arteries of stage 18 chicken embryos.

    Science.gov (United States)

    Lee, Jung Yeop; Lee, Sang Joon

    2010-12-01

    We investigated the thermal effects on heart rate, hemodynamics, and response of vitelline arteries of stage-18 chicken embryos. Heart rate was monitored by a high-speed imaging method, while hemodynamic quantities were evaluated using a particle image velocimetry (PIV) technique. Experiments were carried out at seven different temperatures (36-42 °C with 1 °C interval) after 1h of incubation to stabilize the heart rate. The heart rate increased in a linear manner (r = 0.992). Due to the increased cardiac output (or heart rate), the hemodynamic quantities such as mean velocity (U(mean)), velocity fluctuation (U(fluc)), and peak velocity (U(peak)) also increased with respect to the Womersley number (Ω) in the manner r = 0.599, 0.693, and 0.725, respectively. This indicates that the mechanical force exerting on the vessel walls increases. However, the active response (or regulation) of the vitelline arteries was not observed in this study. Copyright © 2010 Elsevier Ltd. All rights reserved.

  18. An experimental study on feasibility of ex-vessel cooling through the external guide vessel

    International Nuclear Information System (INIS)

    Kang, Kyoung-Ho; Kim, Jong-Hwan; Park, Rae-Jun; Kim, Sang-Baik

    2000-01-01

    This paper presents the results of a series of experiments for assessing the efficacy of ex-vessel cooling through the external guide vessel during a severe accident. Four tests were performed in the LAVA test facility at KAERI, varying the boundary conditions at the outer surface of the vessel. The first test was a dry condition test conducted without cooling the outside of the vessel. On the other hand, in the second test, the cooling of the vessel surface was produced by gravity-driven forced injection of water along the annular gap of 25 mm between the vessel and the external guide vessel. Water flow rate was about 0.85 kg/s and total mass of available water was 300 kg. For the evaluation of the water flow rate effect, the third test was performed with a pool type cooling in the annulus without any circulation of water. These two external cooling tests were performed under elevated pressure of about 1.6 MPa. Finally, the fourth test was conducted under atmospheric pressure to evaluate the effect of system pressure on boiling heat transfer characteristics. In the dry test and the pool type ex-vessel cooling test performed under atmospheric pressure, the vessel was failed by a melt penetration at about 40 degree upper position from the vessel bottom, which is coincident with the boundary of the Al 2 O 3 /Fe melt separated layers. On the other hand, in both of the ex-vessel cooling tests conducted under elevated pressure of about 1.6 MPa, the vessel didn't fail. Compared with the pool boiling test, the vessel experienced effective cooling due to the inlet flow in the forced flow test. Synthesized the results of the tests, it was shown that the heat removal with ex-vessel cooling through the guide vessel is feasible, but the additional evaluations should be performed to guarantee enough thermal margin. (author)

  19. Special enclosure for a pressure vessel

    International Nuclear Information System (INIS)

    Wedellsborg, B.W.; Wedellsborg, U.W.

    1993-01-01

    A pressure vessel enclosure is described comprising a primary pressure vessel, a first pressure vessel containment assembly adapted to enclose said primary pressure vessel and be spaced apart therefrom, a first upper pressure vessel jacket adapted to enclose the upper half of said first pressure vessel containment assembly and be spaced apart therefrom, said upper pressure vessel jacket having an upper rim and a lower rim, each of said rims connected in a slidable relationship to the outer surface of said first pressure vessel containment assembly, mean for connecting in a sealable relationship said upper rim of said first upper pressure vessel jacket to the outer surface of said first pressure vessel containment assembly, means for connecting in a sealable relationship said lower rim of said first upper pressure vessel jacket to the outer surface of said first pressure vessel containment assembly, a first lower pressure vessel jacket adapted to enclose the lower half of said first pressure vessel containment assembly and be spaced apart therefrom, said lower pressure vessel jacket having an upper rim connected in a slidable relationship to the outer surface of said first pressure vessel containment assembly, and means for connecting in a sealable relationship said upper rim of said first lower pressure vessel jacket to the outer surface of said first pressure vessel containment assembly, a second upper pressure vessel jacket adapted to enclose said first upper pressure vessel jacket and be spaced apart therefrom, said second upper pressure vessel jacket having an upper rim and a lower rim, each of said rims adapted to slidably engage the outer surface of said first upper pressure vessel jacket, means for sealing said rims, a second lower pressure vessel jacket adapted to enclose said first lower pressure vessel jacket and be spaced apart therefrom

  20. The alteration of interelemental ratios in myocardium under the congenital heart disease (SRXRF)

    International Nuclear Information System (INIS)

    Trunova, V.A.; Zvereva, V.V.; Okuneva, G.N.; Levicheva, E.N.

    2007-01-01

    It is the myocardium that bears the basic functional loading during heart working, including muscle contractility and enzyme activity. The elemental concentrations in myocardium tissue of heart were determined by SRXRF technique. Our investigation is systematical: the elemental content in each compartment (left and right ventricles, left and right auricles) of hearts of healthy and diseased children (congenital heart diseases, transposition of main vessels (TMV)) was analyzed. The elemental distribution in myocardium of four heart chambers of human fetuses was also analyzed. Following elements were determined: S, Cl, K, Ca, Cr, Mn, Fe, Ni, Cu, Zn, As, Se, Br, Rb, Sr. It was revealed that the elemental concentrations in myocardium of both ventricles are almost constant in heart of fetuses and healthy children. The transition from pre-natal study (fetus) to post-natal study is accompanied by the redistribution of chemical elements in myocardium. The higher concentrations of S, Fe, Ca, Sr and Cu in myocardium of children are observed, the content of K, Br, Rb and especially Se is lower than in heart of fetuses. The elemental distribution in myocardium of children TMV is considerably different in comparison with the healthy children: the higher levels of Cu are observed. The content of Se is lower

  1. Vessel classification method based on vessel behavior in the port of Rotterdam

    NARCIS (Netherlands)

    Zhou, Y.; Daamen, W.; Vellinga, T.; Hoogendoorn, S.P.

    2015-01-01

    AIS (Automatic Identification System) data have proven to be a valuable source to investigate vessel behavior. The analysis of AIS data provides a possibility to recognize vessel behavior patterns in a waterway area. Furthermore, AIS data can be used to classify vessel behavior into several

  2. Vessel Operating Units (Vessels)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set contains data for vessels that are greater than five net tons and have a current US Coast Guard documentation number. Beginning in1979, the NMFS...

  3. Diagnosis and Management of Noncardiac Complications in Adults With Congenital Heart Disease: A Scientific Statement From the American Heart Association.

    Science.gov (United States)

    Lui, George K; Saidi, Arwa; Bhatt, Ami B; Burchill, Luke J; Deen, Jason F; Earing, Michael G; Gewitz, Michael; Ginns, Jonathan; Kay, Joseph D; Kim, Yuli Y; Kovacs, Adrienne H; Krieger, Eric V; Wu, Fred M; Yoo, Shi-Joon

    2017-11-14

    Life expectancy and quality of life for those born with congenital heart disease (CHD) have greatly improved over the past 3 decades. While representing a great advance for these patients, who have been able to move from childhood to successful adult lives in increasing numbers, this development has resulted in an epidemiological shift and a generation of patients who are at risk of developing chronic multisystem disease in adulthood. Noncardiac complications significantly contribute to the morbidity and mortality of adults with CHD. Reduced survival has been documented in patients with CHD with renal dysfunction, restrictive lung disease, anemia, and cirrhosis. Furthermore, as this population ages, atherosclerotic cardiovascular disease and its risk factors are becoming increasingly prevalent. Disorders of psychosocial and cognitive development are key factors affecting the quality of life of these individuals. It is incumbent on physicians who care for patients with CHD to be mindful of the effects that disease of organs other than the heart may have on the well-being of adults with CHD. Further research is needed to understand how these noncardiac complications may affect the long-term outcome in these patients and what modifiable factors can be targeted for preventive intervention. © 2017 American Heart Association, Inc.

  4. Improvement to reactor vessel

    International Nuclear Information System (INIS)

    1974-01-01

    The vessel described includes a prestressed concrete vessel containing a chamber and a removable cover closing this chamber. The cover is in concrete and is kept in its closed position by main and auxiliary retainers, comprising fittings integral with the concrete of the vessel. The auxiliary retainers pass through the concrete of the cover. This improvement may be applied to BWR, PWR and LMFBR type reactor vessel [fr

  5. Blood vessel classification into arteries and veins in retinal images

    Science.gov (United States)

    Kondermann, Claudia; Kondermann, Daniel; Yan, Michelle

    2007-03-01

    The prevalence of diabetes is expected to increase dramatically in coming years; already today it accounts for a major proportion of the health care budget in many countries. Diabetic Retinopathy (DR), a micro vascular complication very often seen in diabetes patients, is the most common cause of visual loss in working age population of developed countries today. Since the possibility of slowing or even stopping the progress of this disease depends on the early detection of DR, an automatic analysis of fundus images would be of great help to the ophthalmologist due to the small size of the symptoms and the large number of patients. An important symptom for DR are abnormally wide veins leading to an unusually low ratio of the average diameter of arteries to veins (AVR). There are also other diseases like high blood pressure or diseases of the pancreas with one symptom being an abnormal AVR value. To determine it, a classification of vessels as arteries or veins is indispensable. As to our knowledge despite the importance there have only been two approaches to vessel classification yet. Therefore we propose an improved method. We compare two feature extraction methods and two classification methods based on support vector machines and neural networks. Given a hand-segmentation of vessels our approach achieves 95.32% correctly classified vessel pixels. This value decreases by 10% on average, if the result of a segmentation algorithm is used as basis for the classification.

  6. Integrating Multiple Autonomous Underwater Vessels, Surface Vessels and Aircraft into Oceanographic Research Vessel Operations

    Science.gov (United States)

    McGillivary, P. A.; Borges de Sousa, J.; Martins, R.; Rajan, K.

    2012-12-01

    Autonomous platforms are increasingly used as components of Integrated Ocean Observing Systems and oceanographic research cruises. Systems deployed can include gliders or propeller-driven autonomous underwater vessels (AUVs), autonomous surface vessels (ASVs), and unmanned aircraft systems (UAS). Prior field campaigns have demonstrated successful communication, sensor data fusion and visualization for studies using gliders and AUVs. However, additional requirements exist for incorporating ASVs and UASs into ship operations. For these systems to be optimally integrated into research vessel data management and operational planning systems involves addressing three key issues: real-time field data availability, platform coordination, and data archiving for later analysis. A fleet of AUVs, ASVs and UAS deployed from a research vessel is best operated as a system integrated with the ship, provided communications among them can be sustained. For this purpose, Disruptive Tolerant Networking (DTN) software protocols for operation in communication-challenged environments help ensure reliable high-bandwidth communications. Additionally, system components need to have considerable onboard autonomy, namely adaptive sampling capabilities using their own onboard sensor data stream analysis. We discuss Oceanographic Decision Support System (ODSS) software currently used for situational awareness and planning onshore, and in the near future event detection and response will be coordinated among multiple vehicles. Results from recent field studies from oceanographic research vessels using AUVs, ASVs and UAS, including the Rapid Environmental Picture (REP-12) cruise, are presented describing methods and results for use of multi-vehicle communication and deliberative control networks, adaptive sampling with single and multiple platforms, issues relating to data management and archiving, and finally challenges that remain in addressing these technological issues. Significantly, the

  7. Safety assessment of a multicavity prestressed concrete reactor vessel with hot liner

    Energy Technology Data Exchange (ETDEWEB)

    Lafitte, R.; Marchand, J. D. [Bonnard et Gardel, Ingenieurs-Conseil, Lausanne (Switzerland)

    1981-01-15

    The prestressed concrete reactor vessel of the high temperature reactor with helium turbine project differs from those realized up to this day by the important number of cavities, by the different cavity pressures and by a liner in contact with hot gas. For the cases of operating conditions, the computations can be based on an identical pressure in all the cavities. The overdimensioning of the vessel which results is not a determining factor at this stage of the project. The possible loss of leaktightness of the liner can introduce gas pressure into the walls of the vessel. The great thickness of the walls makes it impossible to withstand the resulting forces with prestressing in offering sufficient safety factor against collapse. It is thus important to design a drainage network largely dimensioned. The warm liner appears at this stage of the project too highly stressed by fatigue at the singularity points (ducts between cavities, angles). A solution is proposed which limits the variations of thermal stresses by using a steel with low coefficient of thermal expansion. The cavity closures, which are numerous and some with large dimensions are an important aspect of the vessel safety. A solution of reinforced concrete shell with independent liner is proposed.

  8. Safety assessment of a multicavity prestressed concrete reactor vessel with hot liner

    International Nuclear Information System (INIS)

    Lafitte, R.; Marchand, J.D.

    1981-01-01

    The prestressed concrete reactor vessel of the high temperature reactor with helium turbine project differs from those realized up to this day by the important number of cavities, by the different cavity pressures and by a liner in contact with hot gas. For the cases of operating conditions, the computations can be based on an identical pressure in all the cavities. The overdimensioning of the vessel which results is not a determining factor at this stage of the project. The possible loss of leaktightness of the liner can introduce gas pressure into the walls of the vessel. The great thickness of the walls makes it impossible to withstand the resulting forces with prestressing in offering sufficient safety factor against collapse. It is thus important to design a drainage network largely dimensioned. The warm liner appears at this stage of the project too highly stressed by fatigue at the singularity points (ducts between cavities, angles). A solution is proposed which limits the variations of thermal stresses by using a steel with low coefficient of thermal expansion. The cavity closures, which are numerous and some with large dimensions are an important aspect of the vessel safety. A solution of reinforced concrete shell with independent liner is proposed

  9. In-vessel tritium

    International Nuclear Information System (INIS)

    Ueda, Yoshio; Ohya, Kaoru; Ashikawa, Naoko; Ito, Atsushi M.; Kato, Daiji; Kawamura, Gakushi; Takayama, Arimichi; Tomita, Yukihiro; Nakamura, Hiroaki; Ono, Tadayoshi; Kawashima, Hisato; Shimizu, Katsuhiro; Takizuka, Tomonori; Nakano, Tomohide; Nakamura, Makoto; Hoshino, Kazuo; Kenmotsu, Takahiro; Wada, Motoi; Saito, Seiki; Takagi, Ikuji; Tanaka, Yasunori; Tanabe, Tetsuo; Yoshida, Masafumi; Toma, Mitsunori; Hatayama, Akiyoshi; Homma, Yuki; Tolstikhina, Inga Yu.

    2012-01-01

    The in-vessel tritium research is closely related to the plasma-materials interaction. It deals with the edge-plasma-wall interaction, the wall erosion, transport and re-deposition of neutral particles and the effect of neutral particles on the fuel recycling. Since the in-vessel tritium shows a complex nonlinear behavior, there remain many unsolved problems. So far, behaviors of in-vessel tritium have been investigated by two groups A01 and A02. The A01 group performed experiments on accumulation and recovery of tritium in thermonuclear fusion reactors and the A02 group studied theory and simulation on the in-vessel tritium behavior. In the present article, outcomes of the research are reviewed. (author)

  10. [Effects of flunarizine and vitamin C on hemodynamics in rat heart subjected to ischemia-reperfusion].

    Science.gov (United States)

    Xian, Y; Lan, T; Wang, Y

    1998-09-01

    Langendorff perfusion isolated rat heart was subjected to total global ischemia (coronary flow rate is equal to zero) for 10 minutes and reperfusion for 15 minutes. The heart rate (HR), left ventricular developed pressure (LVDP), coronary flow rate (CFR), electrocardiogram (ECG) and the effects of calcium antagonist-flunarizine (FNZ) and/or oxygen free radical scavenger--vitamine C on the above parameters were observed. The results showed that FNZ dilated coronary vessel (P Vitamine C did not affect HR, LVP and CFR. The recovery of the product of HR and LVDP-Rate Pressure Product (RPP) in the FNZ + Vit. C group, Vit. C group and FNZ group was significantly higher than that in the control group (P C may improve the recovery of heart function after reperfusion.

  11. ST Elevation Infarction after Heart Transplantation Induced by Coronary Spasms and Mural Thrombus Detected by Optical Coherence Tomography

    DEFF Research Database (Denmark)

    Clemmensen, Tor Skibsted; Holm, Niels Ramsing; Eiskjær, Hans

    2016-01-01

    The case illustrates the possible link between coronary spasms, intraluminal thrombus formation, and widespread organized and layered thrombi in HTx patients. Furthermore, the case underlines the clinical value of OCT as a novel method for high-resolution vessel imaging in heart-transplanted (HTx...

  12. Congenitally corrected transposition of great arteries with ischemic symptoms in middle age

    International Nuclear Information System (INIS)

    Zaidi, Syed M.; Al-Sharary, Mabrooke M.; Sajid, Najeb U.; Al-Khuwaitir, Tarig S.

    2007-01-01

    Congenitally corrected transposition of great arteries (CCTGA) is a rare congenital disease first described by Von Rokitansky in 1875. Transposition of the great arteries comprises 2.6-7.8% of all cases of congenital heart disease, and if uncorrected, is commonly fatal in first year of life. Patients with corrected transposition of the great arteries without associated defects may remain undiagnosed until adult life. Symptoms occur rarely before the fourth and fifth decades, when rhythm disturbance, left atrioventricular valve regurgitation and moderately impaired systemic ventricular function cause congestive cardiac failure. We report here a case of drug overdose with ischemic symptoms and CCTGA without associated anomalies in a 40-year-old male. (author)

  13. Fibroblast Growth Factor-9 Activates c-Kit Progenitor Cells and Enhances Angiogenesis in the Infarcted Diabetic Heart

    Directory of Open Access Journals (Sweden)

    Dinender Singla

    2016-01-01

    Full Text Available We hypothesized that fibroblast growth factor-9 (FGF-9 would enhance angiogenesis via activating c-kit positive stem cells in the infarcted nondiabetic and diabetic heart. In brief, animals were divided into three groups: Sham, MI, and MI+FGF-9. Two weeks following MI or sham surgery, our data suggest that treatment with FGF-9 significantly diminished vascular apoptosis compared to the MI group in both C57BL/6 and db/db mice (p<0.05. Additionally, the number of c-kit+ve/SM α-actin+ve cells and c-kit+ve/CD31+ve cells were greatly enhanced in the MI+FGF-9 groups relative to the MI suggesting FGF-9 enhances c-Kit cell activation and their differentiation into vascular smooth muscle cells and endothelial cells, respectively (p<0.05. Histology shows that the total number of vessels were quantified for all groups and our data suggest that the FGF-9 treated groups had significantly more vessels than their MI counterparts (p<0.05. Finally, echocardiographic data suggests a significant improvement in left ventricular output, as indicated by fractional shortening and ejection fraction in both nondiabetic and diabetic animals treated with FGF-9 (p<0.05. Overall, our data suggests FGF-9 has the potential to attenuate vascular cell apoptosis, activate c-Kit progenitor cells, and enhance angiogenesis and neovascularization in C57BL/6 and db/db mice leading to improved cardiac function.

  14. Estimation of the compliance of the human capacitance vessels using radionuclide plethysmography

    International Nuclear Information System (INIS)

    Takatsu, Hisato; Gotoh, Kohshi; Suzuki, Takahiko

    1988-01-01

    Radionuclide (RN) plethysmography with Tc-99m RBC was performed in 32 patients with heart disease with the purpose of obtaining compliance of human capacitance vessels. When equilibrium was achieved, RN counts of the region of interest and venous pressure in the forearm were sequentially recorded when the vein of the upper arm was occluded with a cuff inflator. Based on the RN count-venous pressure curve, the specific compliance of the forearm vein and compliance of systemic venous system (SVS) were estimated. In the group of the NYHA functional classification I, which is recognized as hemodynamically ''normal'', the compliance of SVS was 129.8 +- 25.9 ml · mmHg -1 (mean +- SD; n = 9). In comparing the NYHA functional classification and the compliance of SVS, the compliance of SVS was significantly decreased for severer heart failure. Tongue administration of nitroglycerin (0.6 mg) significantly increased the compliance of SVS (p < 0.01). (Namekawa, K.)

  15. Concomitant Avulsion Injury of the Subclavian Vessels and the Main Bronchus Caused by Blunt Trauma.

    Science.gov (United States)

    Noh, Dongsub; Lee, Chan-Kyu; Hwang, Jung Joo; Cho, Hyun Min

    2018-04-01

    Concomitant rupture of the subclavian vessels and the left main bronchus caused by blunt trauma is a serious condition. Moreover, the diagnosis of a tracheobronchial injury with rupture of the subclavian vessels can be difficult. This report describes the case of a 33-year-old man who suffered from blunt trauma that resulted in the rupture of the left subclavian artery and vein. The patient underwent an operation for vascular control. On postoperative day 3, the left main bronchus was found to be transected on a computed tomography scan and bronchoscopy. The transected bronchus was anastomosed in an end-to-end fashion. He recovered without any notable problems. Although the bronchial injury was not detected early, this case of concomitant rupture of the great vessels and the airway was successfully treated after applying extracorporeal membrane oxygenation.

  16. Correlates of lung/heart ratio of thallium-201 in coronary artery disease

    International Nuclear Information System (INIS)

    Homma, S.; Kaul, S.; Boucher, C.A.

    1987-01-01

    We studied 306 patients with chest pain (262 with coronary artery disease and 44 with no coronary artery disease) to determine which of 23 clinical, exercise, thallium, and angiographic variables best discriminate between patients with increased lung/heart ratios of thallium versus those with normal ratios. Normal lung/heart ratio values were defined using an additional 45 subjects with less than 1% probability of coronary artery disease. The number of diseased vessels was the best discriminator between patients with increased ratios versus those with normal ratios. Double product at peak exercise, number of segments with abnormal wall motion, patient gender, and duration of exercise were also significant discriminators. Using discriminant function analysis these variables could correctly identify 81% of cases with increased lung/heart ratios and 72% of cases with normal ratios. These results indicate that an increased lung/heart ratio of thallium reflects exercise-induced left ventricular dysfunction and affords a better understanding of why this thallium parameter is a powerful prognostic indicator in patients with chest pain

  17. Thyroid hormone promotes remodeling of coronary resistance vessels.

    Directory of Open Access Journals (Sweden)

    Olga V Savinova

    Full Text Available Low thyroid hormone (TH function has been linked to impaired coronary blood flow, reduced density of small arterioles, and heart failure. Nonetheless, little is known about the mechanisms by which THs regulate coronary microvascular remodeling. The current study examined the initial cellular events associated with coronary remodeling induced by triiodothyronine (T3 in hypothyroid rats. Rats with established hypothyroidism, eight weeks after surgical thyroidectomy (TX, were treated with T3 for 36 or 72 hours. The early effects of T3 treatment on coronary microvasculature were examined morphometrically. Gene expression changes in the heart were assessed by quantitative PCR Array. Hypothyroidism resulted in arteriolar atrophy in the left ventricle. T3 treatment rapidly induced small arteriolar muscularization and, within 72 hours, restored arteriolar density to control levels. Total length of the capillary network was not affected by TX or T3 treatment. T3 treatment resulted in the coordinate regulation of Angiopoietin 1 and 2 expression. The response of Angiopoietins was consistent with vessel enlargement. In addition to the well known effects of THs on vasoreactivity, these results suggest that THs may affect function of small resistance arteries by phenotypic remodeling of vascular smooth muscle cells (VSMC.

  18. NCSX Vacuum Vessel Fabrication

    International Nuclear Information System (INIS)

    Viola ME; Brown T; Heitzenroeder P; Malinowski F; Reiersen W; Sutton L; Goranson P; Nelson B; Cole M; Manuel M; McCorkle D.

    2005-01-01

    The National Compact Stellarator Experiment (NCSX) is being constructed at the Princeton Plasma Physics Laboratory (PPPL) in conjunction with the Oak Ridge National Laboratory (ORNL). The goal of this experiment is to develop a device which has the steady state properties of a traditional stellarator along with the high performance characteristics of a tokamak. A key element of this device is its highly shaped Inconel 625 vacuum vessel. This paper describes the manufacturing of the vessel. The vessel is being fabricated by Major Tool and Machine, Inc. (MTM) in three identical 120 o vessel segments, corresponding to the three NCSX field periods, in order to accommodate assembly of the device. The port extensions are welded on, leak checked, cut off within 1-inch of the vessel surface at MTM and then reattached at PPPL, to accommodate assembly of the close-fitting modular coils that surround the vessel. The 120 o vessel segments are formed by welding two 60 o segments together. Each 60 o segment is fabricated by welding ten press-formed panels together over a collapsible welding fixture which is needed to precisely position the panels. The vessel is joined at assembly by welding via custom machined 8-inch (20.3 cm) wide spacer ''spool pieces''. The vessel must have a total leak rate less than 5 X 10 -6 t-l/s, magnetic permeability less than 1.02(micro), and its contours must be within 0.188-inch (4.76 mm). It is scheduled for completion in January 2006

  19. Increasing mortality burden among adults with complex congenital heart disease.

    Science.gov (United States)

    Greutmann, Matthias; Tobler, Daniel; Kovacs, Adrienne H; Greutmann-Yantiri, Mehtap; Haile, Sarah R; Held, Leonhard; Ivanov, Joan; Williams, William G; Oechslin, Erwin N; Silversides, Candice K; Colman, Jack M

    2015-01-01

    Progress in management of congenital heart disease has shifted mortality largely to adulthood. However, adult survivors with complex congenital heart disease are not cured and remain at risk of premature death as young adults. Thus, our aim was to describe the evolution and mortality risk of adult patient cohorts with complex congenital heart disease. Among 12,644 adults with congenital heart disease followed at a single center from 1980 to 2009, 176 had Eisenmenger syndrome, 76 had unrepaired cyanotic defects, 221 had atrial switch operations for transposition of the great arteries, 158 had congenitally corrected transposition of the great arteries, 227 had Fontan palliation, and 789 had repaired tetralogy of Fallot. We depict the 30-year evolution of these 6 patient cohorts, analyze survival probabilities in adulthood, and predict future number of deaths through 2029. Since 1980, there has been a steady increase in numbers of patients followed, except in cohorts with Eisenmenger syndrome and unrepaired cyanotic defects. Between 1980 and 2009, 308 patients in the study cohorts (19%) died. At the end of 2009, 85% of survivors were younger than 50 years. Survival estimates for all cohorts were markedly lower than for the general population, with important differences between cohorts. Over the upcoming two decades, we predict a substantial increase in numbers of deaths among young adults with subaortic right ventricles, Fontan palliation, and repaired tetralogy of Fallot. Anticipatory action is needed to prepare clinical services for increasing numbers of young adults at risk of dying from complex congenital heart disease. © 2014 The Authors. Congenital Heart Disease Published by Wiley Periodicals, Inc.

  20. Simulation of In-Vessel Corium Retention through External Reactor Vessel Cooling for SMART using SIMPLE

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Jin-Sung; Son, Donggun; Park, Rae-Joon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    Thermal load analysis from the corium pool to the outer reactor vessel in the lower plenum of the reactor vessel is necessary to evaluate the effect of the IVR-ERVC during a severe accident for SMART. A computational code called SIMPLE (Sever Invessel Melt Progression in Lower plenum Environment) has been developed for analyze transient behavior of molten corium in the lower plenum, interaction between corium and coolant, and heat-up and ablation of reactor vessel wall. In this study, heat load analysis of the reactor vessel for SMART has been conducted using the SIMPLE. Transient behavior of the molten corium in the lower plenum and IVR-ERVC for SMART has been simulated using SIMPLE. Heat flux from the corium pool to the outer reactor vessel is concentrated in metallic layer by the focusing effect. As a result, metallic layer shows higher temperature than the oxidic layer. Also, vessel wall of metallic layer has been ablated by the high in-vessel temperature. Ex-vessel temperature of the metallic layer was maintained 390 K and vessel thickness was maintained 14 cm. It means that the reactor vessel integrity is maintained by the IVR-ERVC.

  1. A computational algorithm addressing how vessel length might depend on vessel diameter

    Science.gov (United States)

    Jing Cai; Shuoxin Zhang; Melvin T. Tyree

    2010-01-01

    The objective of this method paper was to examine a computational algorithm that may reveal how vessel length might depend on vessel diameter within any given stem or species. The computational method requires the assumption that vessels remain approximately constant in diameter over their entire length. When this method is applied to three species or hybrids in the...

  2. Melanopsin mediates light-dependent relaxation in blood vessels.

    Science.gov (United States)

    Sikka, Gautam; Hussmann, G Patrick; Pandey, Deepesh; Cao, Suyi; Hori, Daijiro; Park, Jong Taek; Steppan, Jochen; Kim, Jae Hyung; Barodka, Viachaslau; Myers, Allen C; Santhanam, Lakshmi; Nyhan, Daniel; Halushka, Marc K; Koehler, Raymond C; Snyder, Solomon H; Shimoda, Larissa A; Berkowitz, Dan E

    2014-12-16

    Melanopsin (opsin4; Opn4), a non-image-forming opsin, has been linked to a number of behavioral responses to light, including circadian photo-entrainment, light suppression of activity in nocturnal animals, and alertness in diurnal animals. We report a physiological role for Opn4 in regulating blood vessel function, particularly in the context of photorelaxation. Using PCR, we demonstrate that Opn4 (a classic G protein-coupled receptor) is expressed in blood vessels. Force-tension myography demonstrates that vessels from Opn4(-/-) mice fail to display photorelaxation, which is also inhibited by an Opn4-specific small-molecule inhibitor. The vasorelaxation is wavelength-specific, with a maximal response at ∼430-460 nm. Photorelaxation does not involve endothelial-, nitric oxide-, carbon monoxide-, or cytochrome p450-derived vasoactive prostanoid signaling but is associated with vascular hyperpolarization, as shown by intracellular membrane potential measurements. Signaling is both soluble guanylyl cyclase- and phosphodiesterase 6-dependent but protein kinase G-independent. β-Adrenergic receptor kinase 1 (βARK 1 or GRK2) mediates desensitization of photorelaxation, which is greatly reduced by GRK2 inhibitors. Blue light (455 nM) regulates tail artery vasoreactivity ex vivo and tail blood blood flow in vivo, supporting a potential physiological role for this signaling system. This endogenous opsin-mediated, light-activated molecular switch for vasorelaxation might be harnessed for therapy in diseases in which altered vasoreactivity is a significant pathophysiologic contributor.

  3. Pressure vessel design manual

    CERN Document Server

    Moss, Dennis R

    2013-01-01

    Pressure vessels are closed containers designed to hold gases or liquids at a pressure substantially different from the ambient pressure. They have a variety of applications in industry, including in oil refineries, nuclear reactors, vehicle airbrake reservoirs, and more. The pressure differential with such vessels is dangerous, and due to the risk of accident and fatality around their use, the design, manufacture, operation and inspection of pressure vessels is regulated by engineering authorities and guided by legal codes and standards. Pressure Vessel Design Manual is a solutions-focused guide to the many problems and technical challenges involved in the design of pressure vessels to match stringent standards and codes. It brings together otherwise scattered information and explanations into one easy-to-use resource to minimize research and take readers from problem to solution in the most direct manner possible. * Covers almost all problems that a working pressure vessel designer can expect to face, with ...

  4. LANL Robotic Vessel Scanning

    Energy Technology Data Exchange (ETDEWEB)

    Webber, Nels W. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-11-25

    Los Alamos National Laboratory in J-1 DARHT Operations Group uses 6ft spherical vessels to contain hazardous materials produced in a hydrodynamic experiment. These contaminated vessels must be analyzed by means of a worker entering the vessel to locate, measure, and document every penetration mark on the vessel. If the worker can be replaced by a highly automated robotic system with a high precision scanner, it will eliminate the risks to the worker and provide management with an accurate 3D model of the vessel presenting the existing damage with the flexibility to manipulate the model for better and more in-depth assessment.The project was successful in meeting the primary goal of installing an automated system which scanned a 6ft vessel with an elapsed time of 45 minutes. This robotic system reduces the total time for the original scope of work by 75 minutes and results in excellent data accumulation and transmission to the 3D model imaging program.

  5. Variation of left heart function and thyroid hormone in cirrhosis

    International Nuclear Information System (INIS)

    Liu Junchi; Du Sujun; Mao Shaorong; Lu Jun; Tang Xiaoling

    1996-01-01

    The observation of 52 cases of cirrhosis left heart function indices traced with 113 In m in quiet and motion, and the combining determination of thyroid hormone serum levels with RIA are described. The cirrhosis to the function of liver damage increased, the indices of left heart function has great change. Moreover, the serum levels of T 3 , FT 3 in thyroid hormone are decreased obviously and the serum level of rT 3 is also increased significantly

  6. Classification of heart valve condition using acoustic measurements

    Energy Technology Data Exchange (ETDEWEB)

    Clark, G. [Lawrence Livermore National Lab., CA (United States)

    1994-11-15

    Prosthetic heart valves and the many great strides in valve design have been responsible for extending the life spans of many people with serious heart conditions. Even though the prosthetic valves are extremely reliable, they are eventually susceptible to long-term fatigue and structural failure effects expected from mechanical devices operating over long periods of time. The purpose of our work is to classify the condition of in vivo Bjork-Shiley Convexo-Concave (BSCC) heart valves by processing acoustic measurements of heart valve sounds. The structural failures of interest for Bscc valves is called single leg separation (SLS). SLS can occur if the outlet strut cracks and separates from the main structure of the valve. We measure acoustic opening and closing sounds (waveforms) using high sensitivity contact microphones on the patient`s thorax. For our analysis, we focus our processing and classification efforts on the opening sounds because they yield direct information about outlet strut condition with minimal distortion caused by energy radiated from the valve disc.

  7. PROJECT LIFE CYCLE OF LEASING MARINE VESSEL OWNERS AND CHARTERERS

    Directory of Open Access Journals (Sweden)

    Алла Витальевна БОНДАРЬ

    2016-03-01

    Full Text Available Based on the study of the basic types of the bareboat charter, presented algorithms decision on the justification of the respective projects. It was found that the initiator of the project can be both owners who wants to pass the boat rental and the charterer, and also who is the owner, who wants to take a boat for rent. It is proved that the implementation of these specific operations requires careful preparation, and using of the project approach will greatly enhance their effectiveness. We describe the life of the project finance lease from the standpoint of the marine vessel, the ship-owner and charterer. It is established that such projects characterized by four-phase structure of the life cycle: preparation, let's call it as the principal decision on (from the chartering of the vessel, the investment - to select the optimal variant (from the charter and the conclusion of the bareboat charter, the phase of operation of the vessel and the fourth - the closure of the project at the end of term bareboat charter. Skill description of the content of each phase, which will continue for the main participants of the project to determine the value of each phase and the value of the whole project.

  8. An assessment of acoustic emission for nuclear pressure vessel monitoring

    International Nuclear Information System (INIS)

    Scruby, C.B.

    1983-01-01

    Recent research has greatly improved our understanding of the basic mechanisms of deformation and fracture that generate detectable acoustic emission signals in structural steels. A critical review of the application of acoustic emission (AE) to the fabrication, proof testing and in-service monitoring of nuclear pressure vessels is presented in the light of this improved understanding. The detectability of deformation and fracture processes in pressure vessel steels is discussed, and recommendations made for improving source location accuracy and the development of quantitative source assessment techniques. Published data suggest that AE can make an important contribution to fabrication monitoring, and to the detection of defects in lower toughness materials during vessel proof testing. In high toughness materials, however, the signals generated during ductile crack growth may frequently be too weak for reliable detection. The feasibility of AE for continuous monitoring has not yet been adequately demonstrated because of high background noise levels and uncertainty about AE signal strengths from the defect growth processes that occur in service. In-service leak detection by AE shows considerable promise. It is recommended that further tests are carried out with realistic defects, and under realistic conditions of loading (including thermal shock and fatigue) and of environment. (author)

  9. Study on the abnormal morphogenesis of the arterial end of the heart induced by neutron irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Hidaka, N [Hiroshima Univ. (Japan). Research Inst. for Nuclear Medicine and Biology

    1980-02-01

    Transposition complexes of the great arteries were frequently produced in rat embryonic hearts whose mothers were exposed to a single whole-body dose of 130 rad 14.1 MeV fast neutron radiation on 8 day after conception. To clarify the morphogenesis of transposition complexes, especially double outlet right ventricle (DORV), embryonic rat hearts were serially sectioned and were reconstructed photographically 13 to 16 days after conception, when truncal swelling, intercalated valve swelling, and conical ridges appeared. In the control group, all the hearts had a normal D (dextral) loop. In the experimental group, 82.6% of the hearts had a D loop, 11.3% had an L (levo) loop, and 5.9% had an A (anterior) loop. In this group, the D loop hearts were divided into normal, retarded, and abnormal. Most of the retarded hearts developed into abnormal hearts. The positional relationships between experimentally produced swelling and ridges are classified. Morphologic anomalies are formed in the truncoconal region and correspond to the site of and the quantitative changes of the swelling and ridges. Abnormality in the position and extent of the swelling and ridges is the most important characteristic in the morphogenesis of transposition complexes. The second most important characteristic is abnormality in the time of appearance and the extent and site of cell death in the conical septum. DORV is embryologically divided into two types: a type in which the great arteries are normally related and a type in which they are inversely related. The developmental process of the DORV is entirely different from that of the complete transposition of the great arteries.

  10. PDX vacuum vessel stress analysis

    International Nuclear Information System (INIS)

    Nikodem, Z.D.

    1975-01-01

    A stress analysis of PDX vacuum vessel is described and the summary of results is presented. The vacuum vessel is treated as a toroidal shell of revolution subjected to an internal vacuum. The critical buckling pressure is calculated. The effects of the geometrical discontinuity at the juncture of toroidal shell head and cylindrical outside wall, and the concavity of the cylindrical wall are examined. An effect of the poloidal field coil supports and the vessel outside supports on the stress distribution in the vacuum vessel is determined. A method evaluating the influence of circular ports in the vessel wall on the stress level in the vessel is outlined

  11. Application of harmonic analysis in quantitative heart scintigraphy

    International Nuclear Information System (INIS)

    Fischer, P.; Knopp, R.; Breuel, H.P.

    1979-01-01

    Quantitative scintigraphy of the heart after equilibrium distribution of a radioactive tracer permits the measurement of time activity curves in the left ventricle during a representative heart cycle with great statistical accuracy. By application of Fourier's analysis, criteria are to be attained in addition for evaluation of the volume curve as a whole. Thus the entire information contained in the volume curve is completely described in a Fourier spectrum. Resynthesis after Fourier transformation seems to be an ideal method of smoothing because of its convergence in the minimum quadratic error for the type of function concerned. (orig./MG) [de

  12. Integrated conjugate heat transfer analysis method for in-vessel retention with external reactor vessel cooling - 15477

    International Nuclear Information System (INIS)

    Park, J.W.; Bae, J.H.; Seol, W.C.

    2015-01-01

    An integrated conjugate heat transfer analysis method for the thermal integrity of a reactor vessel under external reactor vessel cooling conditions is developed to resolve light metal layer focusing effect issue. The method calculates steady-state 3-dimensional temperature distribution of a reactor vessel using coupled conjugate heat transfer between in-vessel 3-layered stratified corium (metallic pool, oxide pool and heavy metal) and polar-angle dependent boiling heat transfer at the outer surface of a reactor vessel. The 3-layer corium heat transfer model is utilizing lumped-parameter thermal-resistance circuit method and ex-vessel boiling regimes are parametrically considered. The thermal integrity of a reactor vessel is addressed in terms of un-molten thickness profile. The vessel 3-dimensional heat conduction is validated against a commercial code. It is found that even though the internal heat flux from the metal layer goes far beyond critical heat flux (CHF) the heat flux from the outermost nodes of the vessel may be maintained below CHF due to massive vessel heat diffusion. The heat diffusion throughout the vessel is more pronounced for relatively low heat generation rate in an oxide pool. Parametric calculations are performed considering thermal conditions such as peak heat flux from a light metal layer, heat generation in an oxide pool and external boiling conditions. The major finding is that the most crucial factor for success of in-vessel retention is not the mass of the molten light metal above the oxide pool but the heat generation rate inside the oxide pool and the 3-dimensional vessel heat transfer provides a much larger minimum vessel wall thickness. (authors)

  13. ALICE HMPID Radiator Vessel

    CERN Document Server

    2003-01-01

    View of the radiator vessels of the ALICE/HMPID mounted on the support frame. Each HMPID module is equipped with 3 indipendent radiator vessels made out of neoceram and fused silica (quartz) windows glued together. The spacers inside the vessel are needed to stand the hydrostatic pressure. http://alice-hmpid.web.cern.ch/alice-hmpid

  14. B-type natriuretic peptide as predictor of heart failure in patients with acute ST elevation myocardial infarction, single-vessel disease, and complete revascularization: follow-up study.

    LENUS (Irish Health Repository)

    Manola, Sime

    2012-01-31

    AIM: To assess the concentration of B-type natriuretic peptide (BNP) as a predictor of heart failure in patients with acute ST elevation myocardial infarction (STEMI) who underwent primary percutaneous coronary intervention (PCI) with successful and complete revascularization. METHODS: Out of a total of 220 patients with acute STEMI admitted to the Sisters of Mercy University Hospital in the period January 1 to December 31, 2007, only patients with acute STEMI undergoing primary PCI who had single vessel disease and were successfully revascularized were included in the study. Selected patients had no history of myocardial infarction or heart failure and a normal or near-normal left ventricular ejection fraction (> or =50%) assessed by left ventriculography at admission. Only 58 patients met the inclusion criteria for the study. Out of those, 6 patients refused to participate in the study, and another 5 could not be followed up, so a total of 47 patients were evaluated. Blood samples were taken for measurement of BNP levels at admission, 24 hours later, and 7 days later. Patients were followed up for 1 year. The primary outcome was reduction in left ventricular ejection fraction (LVEF) to <50% after 1 year. RESULTS: Patients who developed echocardiographic signs of reduced systolic function defined as LVEF<50% had significantly higher values of BNP (> or =80 pg\\/mL) at 24 hours (P=0.001) and 7 days (P=0.020) after STEMI and successful reperfusion. Patients who had BNP levels > or =80 pg\\/mL after 7 days were 21 times more likely to develop LVEF<50 (odds ratio, 20.8; 95% confidence interval, 2.2-195.2; P=0.008). CONCLUSION: BNP can be used as a predictor of reduced systolic function in patients with STEMI who underwent successful reperfusion and had normal ejection fraction at admission.

  15. Right ventricular strain in heart failure: Clinical perspective.

    Science.gov (United States)

    Tadic, Marijana; Pieske-Kraigher, Elisabeth; Cuspidi, Cesare; Morris, Daniel A; Burkhardt, Franziska; Baudisch, Ana; Haßfeld, Sabine; Tschöpe, Carsten; Pieske, Burket

    2017-10-01

    The number of studies demonstrating the importance of right ventricular remodelling in a wide range of cardiovascular diseases has increased in the past two decades. Speckle-tracking imaging provides new variables that give comprehensive information about right ventricular function and mechanics. In this review, we summarize current knowledge of right ventricular mechanics in heart failure with reduced ejection fraction and preserved ejection fraction. We searched PubMed, MEDLINE, Ovid and Embase databases for studies published from January 2000 to December 2016 in the English language using the following keywords: "right ventricle"; "strain"; "speckle tracking"; "heart failure with reduced ejection fraction"; and "heart failure with preserved ejection fraction". Investigations showed that right ventricular dysfunction is associated with higher cardiovascular and overall mortality in patients with heart failure, irrespective of ejection fraction. The number of studies investigating right ventricular strain in patients with heart failure with reduced ejection fraction is constantly increasing, whereas data on right ventricular mechanics in patients with heart failure with preserved ejection fraction are limited. Given the high feasibility, accuracy and clinical implications of right ventricular strain in the population with heart failure, it is of great importance to try to include the evaluation of right ventricular strain as a regular part of each echocardiographic examination in patients with heart failure. However, further investigations are necessary to establish right ventricular strain as a standard variable for decision-making. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  16. Why are there no great women chefs?

    Science.gov (United States)

    Druckman, Charlotte

    2010-01-01

    This article applies the rhetorical and deliberately provocative approach of the watershed essay art historian Linda Nochlin wrote in 1971—“Why Have there Been No Great Women Artists?”—to today's culinary industry. Nochlin used the question her title posed as a theoretical trap that would draw attention not only to the inherent sexism or prejudice that pervades the way the public perceives art, but also to those same issues' existence within and impact on academia and the other cultural institutions responsible for posing these sorts of questions. Nochlin bypassed the obvious and irrelevant debate over women's being less or differently talented and, in so doing, exposed that debate for being a distraction from the heart of the matter: how, sociologically (media) or institutionally (museums, foundations, etc.), people define a “great artist.” Although it's 40 years later, the polemic is as effective when used to understand the gender divide in the food world.

  17. 78 FR 42452 - Safety Zone; Kentucky Air National Guard Vessel for Parachute Rescue Jumpmaster Training, Lake...

    Science.gov (United States)

    2013-07-16

    ... only a few hours at a time during any 24 hour period. The majority of the training exercises will be... greatly reducing the likelihood of affecting transient recreational vessels. Additionally, the starting... Health Risks and Safety Risks. This rule is not an economically significant rule and does not create an...

  18. Reactor vessel sealing plug

    International Nuclear Information System (INIS)

    Dooley, R.A.

    1986-01-01

    This invention relates to an apparatus and method for sealing the cold leg nozzles of a nuclear reactor pressure vessel from a remote location during maintenance and inspection of associated steam generators and pumps while the pressure vessel and refueling canal are filled with water. The apparatus includes a sealing plug for mechanically sealing the cold leg nozzle from the inside of a reactor pressure vessel. The sealing plugs include a primary and a secondary O-ring. An installation tool is suspended within the reactor vessel and carries the sealing plug. The tool telescopes to insert the sealing plug within the cold leg nozzle, and to subsequently remove the plug. Hydraulic means are used to activate the sealing plug, and support means serve to suspend the installation tool within the reactor vessel during installation and removal of the sealing plug

  19. β-adrenergic receptor responsiveness in aging heart and clinical implications

    Science.gov (United States)

    Ferrara, Nicola; Komici, Klara; Corbi, Graziamaria; Pagano, Gennaro; Furgi, Giuseppe; Rengo, Carlo; Femminella, Grazia D.; Leosco, Dario; Bonaduce, Domenico

    2014-01-01

    Elderly healthy individuals have a reduced exercise tolerance and a decreased left ventricle inotropic reserve related to increased vascular afterload, arterial-ventricular load mismatching, physical deconditioning and impaired autonomic regulation (the so called “β-adrenergic desensitization”). Adrenergic responsiveness is altered with aging and the age-related changes are limited to the β-adrenergic receptor density reduction and to the β-adrenoceptor-G-protein(s)-adenylyl cyclase system abnormalities, while the type and level of abnormalities change with species and tissues. Epidemiological studies have shown an high incidence and prevalence of heart failure in the elderly and a great body of evidence correlate the changes of β-adrenergic system with heart failure pathogenesis. In particular it is well known that: (a) levels of cathecolamines are directly correlated with mortality and functional status in heart failure, (b) β1-adrenergic receptor subtype is down-regulated in heart failure, (c) heart failure-dependent cardiac adrenergic responsiveness reduction is related to changes in G proteins activity. In this review we focus on the cardiovascular β-adrenergic changes involvement in the aging process and on similarities and differences between aging heart and heart failure. PMID:24409150

  20. Feasibility of electron beam tomography in diagnosis of congenital heart disease: comparison with echocardiography

    International Nuclear Information System (INIS)

    Lee, Jongmin J.; Kang, Duk-Sik

    2001-01-01

    Objective: To evaluate the feasibility of electron beam tomography (EBT) for morphological assessment of congenital heart disease. Materials and methods: Sixteen subjects were examined by EBT, transthoracic echocardiography, cardiac cine angiography and surgery. EBT scan was performed using single slice continuous volume mode to acquire high-resolution static image. Double dose contrast medium was injected by bolus technique after measuring scan delay time and calculation of proper injection rate. The results of EBT and echocardiography were compared based on the results of cardiac cine angiography and surgical findings. All anomalous components were evaluated in all subjects and grouped according to major cardiac structures. Statistical analysis was performed to compare two modalities' ability to evaluate the anomalies of major structures. Results: EBT was more sensitive to evaluate the anomalies of systemic vessels, pulmonary vessels and small systemic arteries such as coronary artery. EBT was less sensitive to identify the abnormality of cardiac valves such as valvular regurgitation. There was no difference of sensitivity in evaluation of cardiac chambers and septa between the two modalities. Conclusion: EBT assisted by transthoracic echocardiography is excellent noninvasive modality to diagnose congenital heart disease

  1. Recent evaluation of 'wet' thermal annealing to resolve reactor pressure vessel embrittlement

    International Nuclear Information System (INIS)

    Server, W.L.; Biemiller, E.C.

    1993-01-01

    Prior to the decision to close the Yankee Rowe plant in 1992, a great deal of effort was expended in trying to resolve the degree of neutron embrittlement that the reactor pressure vessel had experienced after 30 years of operation. One mitigative measure that was examined in detail was the possibility of performing a relatively low temperature thermal anneal (at approximately 650 deg. F) to partially restore the original design level of mechanical properties of the reactor pressure vessel beltline region which were lost due to the neutron radiation exposure. This low temperature anneal was to involve heating of the primary coolant water using pump heat in a similar manner as that used to anneal the Belgian BR-3 reactor pressure vessel in the early 1980s. This 'wet' anneal was successful in recovering mechanical properties for the BR-3 vessel, but the extent of the recovery, as well as the rate of re-embrittlement after the anneal, were issues that were difficult to quantify since the exact reactor pressure vessel steels were not available for experimental verification. For the case of Yankee Rowe, material was available from past surveillance programs for at least one of the materials in the vessel, as well as materials obtained from various sources which could act as bounding surrogates. An irradiation /annealing/reirradiation program was developed to better quantify the degree of recovery and re-embrittlement for these materials, but this program was halted before significant test results were obtained. Prior to the initiation of the testing program, a review of past annealing data was performed and the data were scrutinized for direct relevance to the annealing response of the Yankee Rowe vessel. This paper discusses the results derived from this review. The results from the critical review of the past annealing data indicated that a 'wet' anneal of the Yankee Rowe vessel may have been successful in reducing the degree of embrittlement to the point that the

  2. Structural features and in-service inspection of the LTHR-200 pressure vessel

    International Nuclear Information System (INIS)

    Xiong Dunshi; He Shuyan; Liu Junjie; Yu Suyuan

    1993-01-01

    LTHR-200 is a low temperature district-heating reactor. It adopts double-shell design pressure vessel and metal containment. Because of the safety and structural features of the reactor, the in-service inspection of the pressure vessel can be simplified greatly. LTHR-200 is an integrated arrangement. Both its core components and the main heat exchangers are contained in the reactor pressure vessel. The coolant of the main loop is run by a full-power natural circulation and there need no main pumps and pipes. Thus, the reactor pressure vessel constitutes the pressure boundary of the reactor's main loop coolant. In regard to these features, a small-sized containment is designed for the reactor. The metal safety container with a small volume is placed closely around the reactor pressure vessel. Outside the metal containment, there is a large reinforced concrete construction for the reactor. Their main operation and design parameters are as follows: The pressure vessel: operation pressure = 2.4 MPa; design pressure = 3.0 MPa; design temperature = 250 deg C; 40 year fast neutron (E>1MeV) fluence in the belt-line region = < 10E16n/cm; internal diameter = 5000 mm; material SA516-70; shell thickness 65 mm; The metal containment: maximum operation pressure = 1.8 MPa; design pressure = 1.8 MPa; design temperature = 250 deg. C; upper internal diameter 7000 mm; lower internal diameter = 5600 mm; material = SA516-70; shell thickness, upper part = 80 mm; lower part = 50 mm. All penetrating pipes through the pressure vessel are located at the top penetration section of the shell. All the internal diameters of penetrating pipes are less than 50 mm. Inside and outside the metal containment wall respectively, isolating valves are connected to the reactor coolant pipe which passes through the containment. These two isolating valves use different driving methods. Every penetrating part of the reactor construction uses a proper form of structure according to safety requirements

  3. Reactor vessel stud closure system

    International Nuclear Information System (INIS)

    Spiegelman, S.R.; Salton, R.B.; Beer, R.W.; Malandra, L.J.; Cognevich, M.L.

    1982-01-01

    A quick-acting stud tensioner apparatus for enabling the loosening or tightening of a stud nut on a reactor vessel stud. The apparatus is adapted to engage the vessel stud by closing a gripper around an upper end of the vessel stud when the apparatus is seated on the stud. Upon lifting the apparatus, the gripper releases the vessel stud so that the apparatus can be removed

  4. Containment vessel drain system

    Science.gov (United States)

    Harris, Scott G.

    2018-01-30

    A system for draining a containment vessel may include a drain inlet located in a lower portion of the containment vessel. The containment vessel may be at least partially filled with a liquid, and the drain inlet may be located below a surface of the liquid. The system may further comprise an inlet located in an upper portion of the containment vessel. The inlet may be configured to insert pressurized gas into the containment vessel to form a pressurized region above the surface of the liquid, and the pressurized region may operate to apply a surface pressure that forces the liquid into the drain inlet. Additionally, a fluid separation device may be operatively connected to the drain inlet. The fluid separation device may be configured to separate the liquid from the pressurized gas that enters the drain inlet after the surface of the liquid falls below the drain inlet.

  5. The helical ventricular myocardial band of Torrent-Guasp: potential implications in congenital heart defects.

    Science.gov (United States)

    Corno, Antonio F; Kocica, Mladen J; Torrent-Guasp, Francisco

    2006-04-01

    The new concepts of cardiac anatomy and physiology, based on the observations made by Francisco Torrent-Guasp's discovery of the helical ventricular myocardial band, can be useful in the context of the surgical strategies currently used to manage patients with congenital heart defects. The potential impact of the Torrent-Guasp's Heart on congenital heart defects have been analyzed in the following settings: ventriculo-arterial discordance (transposition of the great arteries), double (atrio-ventricular and ventriculo-arterial) discordance (congenitally corrected transposition of the great arteries), Ebstein's anomaly, pulmonary valve regurgitation after repair of tetralogy of Fallot, Ross operation, and complex intra-ventricular malformations. The functional interaction of right and left ventricles occurs not only through their arrangements in series but also thanks to the structural spiral features. Changes in size and function of either ventricle may influence the performance of the other ventricle. The variety and complexity of congenital heart defects make the recognition of the relationship between form and function a vital component, especially when compared to acquired disease. The new concepts of cardiac anatomy and function proposed by Francisco Torrent-Guasp, based on his observations, should stimulate further investigations of alternative surgical strategies by individuals involved with the management of patients with congenital heart defects.

  6. Mobile nuclear reactor containment vessel

    International Nuclear Information System (INIS)

    Thompson, R.E.; Spurrier, F.R.; Jones, A.R.

    1978-01-01

    A containment vessel for use in mobile nuclear reactor installations is described. The containment vessel completely surrounds the entire primary system, and is located as close to the reactor primary system components as is possible in order to minimize weight. In addition to being designed to withstand a specified internal pressure, the containment vessel is also designed to maintain integrity as a containment vessel in case of a possible collision accident

  7. Thermal Behavior of the Reactor Vessel Penetration Under External Vessel Cooling During a Severe Accident

    International Nuclear Information System (INIS)

    Kang, Kyoung-Ho; Park, Rae-Joon; Kim, Jong-Tae; Min, Byung-Tae; Lee, Ki-Young; Kim, Sang-Baik

    2004-01-01

    Experimental and analytical studies on the thermal behavior of reactor vessel penetration have been performed under external vessel cooling during a severe accident in the Korean next-generation reactor APR1400. Two types of tests, SUS-EXT and SUS-DRY with and without external vessel cooling, respectively, have been performed using sustained heating by an induction heater. Three tests have been carried out varying the cooling conditions at the vessel outer surface in the SUS-EXT tests. The experimental results have been thermally estimated using the LILAC computer code. The experimental results indicate that the inner surface of the vessel was ablated by the 45-mm thickness in the SUS-DRY test. Despite the total ablation of the welding material, the penetration was not ejected outside the vessel, which could be attributed to the thermal expansion of the penetration. Unlike the SUS-DRY test, the thickness of the ablation was ∼15 to 20 mm at most, so the welding was preserved in the SUS-EXT tests. It is concluded from the experimental results that the external vessel cooling highly affected the ablation configuration and the thermal behaviors of the vessel and the penetration. An increase in coolant mass flow rate from 0.047 to 0.152 kg/s had effects on the thermal behavior of the lower head vessel and penetration in the SUS-EXT tests. The LILAC analytical results on temperature distribution and ablation depth in the lower head vessel and penetration were very similar to the experimental results

  8. Neutrophil-Mediated Delivery of Therapeutic Nanoparticles across Blood Vessel Barrier for Treatment of Inflammation and Infection.

    Science.gov (United States)

    Chu, Dafeng; Gao, Jin; Wang, Zhenjia

    2015-12-22

    Endothelial cells form a monolayer in lumen of blood vessels presenting a great barrier for delivery of therapeutic nanoparticles (NPs) into extravascular tissues where most diseases occur, such as inflammation disorders and infection. Here, we report a strategy for delivering therapeutic NPs across this blood vessel barrier by nanoparticle in situ hitchhiking activated neutrophils. Using intravital microscopy of TNF-α-induced inflammation of mouse cremaster venules and a mouse model of acute lung inflammation, we demonstrated that intravenously (iv) infused NPs made from denatured bovine serum albumin (BSA) were specifically internalized by activated neutrophils, and subsequently, the neutrophils containing NPs migrated across blood vessels into inflammatory tissues. When neutrophils were depleted using anti-Gr-1 in a mouse, the transport of albumin NPs across blood vessel walls was robustly abolished. Furthermore, it was found that albumin nanoparticle internalization did not affect neutrophil mobility and functions. Administration of drug-loaded albumin NPs markedly mitigated the lung inflammation induced by LPS (lipopolysaccharide) or infection by Pseudomonas aeruginosa. These results demonstrate the use of an albumin nanoparticle platform for in situ targeting of activated neutrophils for delivery of therapeutics across the blood vessel barriers into diseased sites. This study demonstrates our ability to hijack neutrophils to deliver nanoparticles to targeted diseased sites.

  9. Gold nanoparticles administration induces disarray of heart muscle, hemorrhagic, chronic inflammatory cells infiltrated by small lymphocytes, cytoplasmic vacuolization and congested and dilated blood vessels

    Directory of Open Access Journals (Sweden)

    Abdelhalim Mohamed Anwar K

    2011-12-01

    Full Text Available Abstract Background Despite significant research efforts on cancer therapy, diagnostics and imaging, many challenges remain unsolved. There are many unknown details regarding the interaction of nanoparticles (NPs and biological systems. The structure and properties of gold nanoparticles (GNPs make them useful for a wide array of biological applications. However, for the application of GNPs in therapy and drug delivery, knowledge regarding their bioaccumulation and associated local or systemic toxicity is necessary. Information on the biological fate of NPs, including distribution, accumulation, metabolism, and organ specific toxicity is still minimal. Studies specifically dealing with the toxicity of NPs are rare. The aim of the present study was to investigate the effects of intraperitoneal administration of GNPs on histological alterations of the heart tissue of rats in an attempt to identify and understand the toxicity and the potential role of GNPs as a therapeutic and diagnostic tool. Methods A total of 40 healthy male Wistar-Kyoto rats received 50 μl infusions of 10, 20 and 50 nm GNPs for 3 or 7 days. Animals were randomly divided into groups: 6 GNP-treated rats groups and one control group (NG. Groups 1, 2 and 3 received infusions of 50 μl GNPs of size 10 nm (3 or 7 days, 20 nm (3 or 7 days and 50 nm (3 or 7 days, respectively. Results In comparison with the respective control rats, exposure to GNPs doses produced heart muscle disarray with a few scattered chronic inflammatory cells infiltrated by small lymphocytes, foci of hemorrhage with extravasation of red blood cells, some scattered cytoplasmic vacuolization and congested and dilated blood vessels. None of the above alterations were observed in the heart muscle of any member of the control group. Conclusions The alterations induced by intraperitoneal administration of GNPs were size-dependent, with smaller ones inducing greater affects, and were also related to the time exposure to

  10. Valvular Heart Disease in Heart Failure

    Directory of Open Access Journals (Sweden)

    Giuseppe MC Rosano

    2017-01-01

    Full Text Available Structural valvular heart disease may be the cause of heart failure or may worsen the clinical status of patients with heart failure. Heart failure may also develop in patients treated with valve surgery. Patients with heart failure with valvular heart disease are at increased risk of events including sudden cardiac death. Before considering intervention (surgical or percutaneous all patients should receive appropriate medical and device therapy taking into account that vasodilators must be used with caution in patients with severe aortic stenosis. Numerous percutaneous and/or hybrid procedures have been introduced in the past few years and they are changing the management of valvular heart disease. In patients with heart failure and valvular heart disease, either primary or functional, the whole process of decision-making should be staged through a comprehensive evaluation of the risk– benefit ratio of different treatment strategies and should be made by a multidisciplinary ‘heart team’ with a particular expertise in valvular heart disease. The heart team should include heart failure cardiologists, cardiac surgeons/structural valve interventionists, imaging specialists, anaesthetists, geriatricians and intensive care specialists. This article will review recent developments and distill practical guidance in the management of this important heart failure co-morbidity.

  11. Transposition of the great vessels

    Science.gov (United States)

    ... as atrial septal defect, ventricular septal defect, or patent ductus arteriosus) and how much the blood can ... develop, get worse, or continue after treatment. Prevention Women who plan to become pregnant should be immunized ...

  12. [Possible effect of E-selectine on structure and function of arterial vessels in patients with metabolic syndrome].

    Science.gov (United States)

    Voloshyna, O O; Lyzohub, V H; Romanenko, I M

    2007-01-01

    Endothelial dysfunction and endothelial cells activation as it was shown in patients with ischemic heart disease play important role in atherosclerosis progression and the development of cardiovascular events. Relationship between E-selectine and functional/ structural changes of the arterial vessels in patients with metabolic syndrome was not explored. We revealed that both activation of the endothelial cells and structural/functional changes of the arterial wall mostly depend on obesity and dislipedemia and in less extent on carbohydrates metabolism disorders.

  13. Nuclear reactor vessel decontamination systems

    International Nuclear Information System (INIS)

    McGuire, P. J.

    1985-01-01

    There is disclosed in the present application, a decontamination system for reactor vessels. The system is operatable without entry by personnel into the contaminated vessel before the decontamination operation is carried out and comprises an assembly which is introduced into the vertical cylindrical vessel of the typical boiling water reactor through the open top. The assembly includes a circular track which is centered by guideways permanently installed in the reactor vessel and the track guides opposed pairs of nozzles through which water under very high pressure is directed at the wall for progressively cutting and sweeping a tenacious radioactive coating as the nozzles are driven around the track in close proximity to the vessel wall. The whole assembly is hoisted to a level above the top of the vessel by a crane, outboard slides on the assembly brought into engagement with the permanent guideways and the assembly progressively lowered in the vessel as the decontamination operation progresses. The assembly also includes a low pressure nozzle which forms a spray umbrella above the high pressure nozzles to contain radioactive particles dislodged during the decontamination

  14. Mechano-electric feedback in the fish heart.

    Directory of Open Access Journals (Sweden)

    Simon M Patrick

    2010-05-01

    Full Text Available Mechanoelectric feedback (MEF describes the modulation of electrical activity by mechanical activity. This may occur via the activation of mechanosensitive ion channels (MSCs. MEF has not previously been investigated in fish ventricular tissue even though fish can greatly increase ventricular end diastolic volume during exercise which should therefore provide a powerful mechanical stimulus for MEF.When the ventricles of extrinsically paced, isolated working trout hearts were dilated by increasing afterload, monophasic action potential (MAP duration was significantly shortened at 25% repolarisation, unaltered at 50% repolarisation and significantly lengthened at 90% repolarisation. This observation is consistent with the activation of cationic non-selective MSCs (MSC(NSs. We then cloned the trout ortholog of TRPC1, a candidate MSC(NS and confirmed its presence in the trout heart.Our results have validated the use of MAP technology for the fish heart and suggest that, in common with amphibians and mammals, MEF operates in fish ventricular myocardium, possibly via the activation of mechanosensitive TRPC1 ion channels.

  15. What is cerebral small vessel disease?

    International Nuclear Information System (INIS)

    Onodera, Osamu

    2011-01-01

    An accumulating amount of evidence suggests that the white matter hyperintensities on T 2 weighted brain magnetic resonance imaging predict an increased risk of dementia and gait disturbance. This state has been proposed as cerebral small vessel disease, including leukoaraiosis, Binswanger's disease, lacunar stroke and cerebral microbleeds. However, the concept of cerebral small vessel disease is still obscure. To understand the cerebral small vessel disease, the precise structure and function of cerebral small vessels must be clarified. Cerebral small vessels include several different arteries which have different anatomical structures and functions. Important functions of the cerebral small vessels are blood-brain barrier and perivasucular drainage of interstitial fluid from the brain parenchyma. Cerebral capillaries and glial endfeet, take an important role for these functions. However, the previous pathological investigations on cerebral small vessels have focused on larger arteries than capillaries. Therefore little is known about the pathology of capillaries in small vessel disease. The recent discoveries of genes which cause the cerebral small vessel disease indicate that the cerebral small vessel diseases are caused by a distinct molecular mechanism. One of the pathological findings in hereditary cerebral small vessel disease is the loss of smooth muscle cells, which is an also well-recognized finding in sporadic cerebral small vessel disease. Since pericytes have similar character with the smooth muscle cells, the pericytes should be investigated in these disorders. In addition, the loss of smooth muscle cells may result in dysfunction of drainage of interstitial fluid from capillaries. The precise correlation between the loss of smooth muscle cells and white matter disease is still unknown. However, the function that is specific to cerebral small vessel may be associated with the pathogenesis of cerebral small vessel disease. (author)

  16. Heart Failure with Transient Left Bundle Branch Block in the Setting of Left Coronary Fistula

    Directory of Open Access Journals (Sweden)

    Stephen P. Juraschek

    2011-01-01

    Full Text Available Coronary arterial fistulas are rare communications between vessels or chambers of the heart. Although cardiac symptoms associated with fistulas are well described, fistulas are seldom considered in the differential diagnosis of acute myocardial ischemia. We describe the case of a 64-year-old man who presented with left shoulder pain, signs of heart failure, and a new left bundle branch block (LBBB. Cardiac catheterization revealed a small left anterior descending (LAD-to-pulmonary artery (PA fistula. Diuresis led to subjective improvement of the patient's symptoms and within several days the LBBB resolved. We hypothesize that the coronary fistula in this patient contributed to transient ischemia of the LAD territory through a coronary steal mechanism. We elected to observe rather than repair the fistula, as his symptoms and ECG changes resolved with treatment of his heart failure.

  17. Changing Landscape of Congenital Heart Disease.

    Science.gov (United States)

    Bouma, Berto J; Mulder, Barbara J M

    2017-03-17

    Congenital heart disease is the most frequently occurring congenital disorder affecting ≈0.8% of live births. Thanks to great efforts and technical improvements, including the development of cardiopulmonary bypass in the 1950s, large-scale repair in these patients became possible, with subsequent dramatic reduction in morbidity and mortality. The ongoing search for progress and the growing understanding of the cardiovascular system and its pathophysiology refined all aspects of care for these patients. As a consequence, survival further increased over the past decades, and a new group of patients, those who survived congenital heart disease into adulthood, emerged. However, a large range of complications raised at the horizon as arrhythmias, endocarditis, pulmonary hypertension, and heart failure, and the need for additional treatment became clear. Technical solutions were sought in perfection and creation of new surgical techniques by developing catheter-based interventions, with elimination of open heart surgery and new electronic devices enabling, for example, multisite pacing and implantation of internal cardiac defibrillators to prevent sudden death. Over time, many pharmaceutical studies were conducted, changing clinical treatment slowly toward evidence-based care, although results were often limited by low numbers and clinical heterogeneity. More attention has been given to secondary issues like sports participation, pregnancy, work, and social-related difficulties. The relevance of these issues was already recognized in the 1970s when the need for specialized centers with multidisciplinary teams was proclaimed. Finally, research has become incorporated in care. Results of intervention studies and registries increased the knowledge on epidemiology of adults with congenital heart disease and their complications during life, and at the end, several guidelines became easily accessible, guiding physicians to deliver care appropriately. Over the past decades

  18. Analysis of mechanical property data obtained from nuclear pressure vessel surveillance capsules

    International Nuclear Information System (INIS)

    Perrin, J.S.

    1977-01-01

    A typical pressure vessel surveillance capsule examination program provides mechanical property data from tensile, Charpy V-notch impact, and, in some cases, fracture mechanics specimens. This data must be analyzed in conjunction with the unirradiated baseline mechanical property data to determine the effect of irradiation on the mechanical properties. In the case of Charpy impact specimens, for example, irradiation typically causes an increase in the transition temperature, and a decrease in the upper shelf energy level. The results of the Charpy impact and other mechanical specimen tests must be evaluated to determine if property changes are occurring in the manner expected when the reactor was put into service. The large amount of data obtained from surveillance capsule examinations in recent years enables one to make fairly good predictions. After the changes in the mechanical properties of specimens from a particular surveillance capsule have been experimentally determined and evaluated, they must be related to the reactor pressure vessel. This requires a knowledge of the neutron fluence of the surveillance capsule, and the ratio of the surveillance capsule fluence to the pressure vessel wall fluence. This ratio is frequently specified by the reactor manufacturer, or can be calculated from a knowledge of the geometry and materials of the reactor components inside the pressure vessel. A knowledge of the exact neutron fluence of the capsule specimens and the capsule to vessel wall neutron fluence ratio is of great importance, since inaccuracies in these numbers cause just as serious a problem as inaccuracies in the mechanical property determinations. A further area causing analysis difficulties is problems encountered in recent capsule programs relating to capsule design, construction, operation, and dismantling. (author)

  19. Heart Health - Brave Heart

    Science.gov (United States)

    ... Bar Home Current Issue Past Issues Cover Story Heart Health Brave Heart Past Issues / Winter 2009 Table of Contents For ... you can have a good life after a heart attack." Lifestyle Changes Surviving—and thriving—after such ...

  20. Captopril improves tumor nanomedicine delivery by increasing tumor blood perfusion and enlarging endothelial gaps in tumor blood vessels.

    Science.gov (United States)

    Zhang, Bo; Jiang, Ting; Tuo, Yanyan; Jin, Kai; Luo, Zimiao; Shi, Wei; Mei, Heng; Hu, Yu; Pang, Zhiqing; Jiang, Xinguo

    2017-12-01

    Poor tumor perfusion and unfavorable vessel permeability compromise nanomedicine drug delivery to tumors. Captopril dilates blood vessels, reducing blood pressure clinically and bradykinin, as the downstream signaling moiety of captopril, is capable of dilating blood vessels and effectively increasing vessel permeability. The hypothesis behind this study was that captopril can dilate tumor blood vessels, improving tumor perfusion and simultaneously enlarge the endothelial gaps of tumor vessels, therefore enhancing nanomedicine drug delivery for tumor therapy. Using the U87 tumor xenograft with abundant blood vessels as the tumor model, tumor perfusion experiments were carried out using laser Doppler imaging and lectin-labeling experiments. A single treatment of captopril at a dose of 100 mg/kg significantly increased the percentage of functional vessels in tumor tissues and improved tumor blood perfusion. Scanning electron microscopy of tumor vessels also indicated that the endothelial gaps of tumor vessels were enlarged after captopril treatment. Immunofluorescence-staining of tumor slices demonstrated that captopril significantly increased bradykinin expression, possibly explaining tumor perfusion improvements and endothelial gap enlargement. Additionally, imaging in vivo, imaging ex vivo and nanoparticle distribution in tumor slices indicated that after a single treatment with captopril, the accumulation of 115-nm nanoparticles in tumors had increased 2.81-fold with a more homogeneous distribution pattern in comparison to non-captopril treated controls. Finally, pharmacodynamics experiments demonstrated that captopril combined with paclitaxel-loaded nanoparticles resulted in the greatest tumor shrinkage and the most extensive necrosis in tumor tissues among all treatment groups. Taken together, the data from the present study suggest a novel strategy for improving tumor perfusion and enlarging blood vessel permeability simultaneously in order to improve

  1. Nuclear reactor vessel inspection apparatus

    International Nuclear Information System (INIS)

    Blackstone, E.G.; Lofy, R.A.; Williams, L.P.

    1979-01-01

    Apparatus for the in situ inspection of a nuclear reactor vessel to detect the location and character of flaws in the walls of the vessel, in the welds joining the various sections of the vessel, in the welds joining attachments such as nozzles, elbows and the like to the reactor vessel and in such attachments wherein an inspection head carrying one or more ultrasonic transducers follows predetermined paths in scanning the various reactor sections, welds and attachments

  2. Critical review-current status of Tl-201 myocardial scintigraphy in patients with ischemic heart disease

    International Nuclear Information System (INIS)

    Kanemoto, Nariaki; Hoer, G.

    1982-01-01

    Thallium-201 myocardial scintigraphy (TMS) is the most important, accurate and noninvasive diagnostic tool for the detection of regional myocardial perfusion. This agent is a potassium analog and the biologic half life in normal myocardium is 4 hours. Therefore, serial imaging after a single dose of Tl-201 at the peak of the exercise makes differential diagnosis possible between stress induced ischemia (transient perfusion defect with redistribution) and myocardial fibrosis or scar (permanent defect). The reproducibility is around 90%. The overall sensitivity in 4,094 patients reviewed from the literature was 83% with a specificity of 87%. The accuracy of TMS for the diagnosis of ischemic heart disease was 85%. Sensitivity increases in the order of visual (83%), computer analysis of standard scintigraphy (91%), and computer analysis of pinhole tomography (96%), but there is no significant difference in specificity among them. Also, sensitivity increases in the order of single (73%), double (83%) and triple (90%) vessel d isease. However, TMS does not indicate the correct number of vessels involved. In this paper, we discuss the current status of use and limitations of TMS in the diagnosis of ischemic heart disease. (author)

  3. Cells and Angiogenic Cytokines in Therapeutic Angiogenesis for Ischemic Heart Disease

    DEFF Research Database (Denmark)

    Luo, Yu; Zhang, Dai-Fu; Liang, Bo

    2005-01-01

    In the past 20 to 30 years,great developments had been achieved in the applying of cells and angiogenic cytokines for ischemic heart disease.The thesis reviews latest studies of mechanism and clinic application of this novel therapy....

  4. Congenital heart disease and chromossomopathies detected by the karyotype

    Directory of Open Access Journals (Sweden)

    Patrícia Trevisan

    2014-06-01

    Full Text Available OBJECTIVE: To review the relationship between congenital heart defects and chromosomal abnormalities detected by the karyotype.DATA SOURCES: Scientific articles were searched in MEDLINE database, using the descriptors "karyotype" OR "chromosomal" OR "chromosome" AND "heart defects, congenital". The research was limited to articles published in English from 1980 on.DATA SYNTHESIS: Congenital heart disease is characterized by an etiologically heterogeneous and not well understood group of lesions. Several researchers have evaluated the presence of chromosomal abnormalities detected by the karyotype in patients with congenital heart disease. However, most of the articles were retrospective studies developed in Europe and only some of the studied patients had a karyotype exam. In this review, only one study was conducted in Latin America, in Brazil. It is known that chromosomal abnormalities are frequent, being present in about one in every ten patients with congenital heart disease. Among the karyotype alterations in these patients, the most important is the trisomy 21 (Down syndrome. These patients often have associated extra-cardiac malformations, with a higher risk of morbidity and mortality, which makes heart surgery even more risky.CONCLUSIONS: Despite all the progress made in recent decades in the field of cytogenetic, the karyotype remains an essential tool in order to evaluate patients with congenital heart disease. The detailed dysmorphological physical examination is of great importance to indicate the need of a karyotype.

  5. Congenital heart disease and chromossomopathies detected by the karyotype

    Science.gov (United States)

    Trevisan, Patrícia; Rosa, Rafael Fabiano M.; Koshiyama, Dayane Bohn; Zen, Tatiana Diehl; Paskulin, Giorgio Adriano; Zen, Paulo Ricardo G.

    2014-01-01

    OBJECTIVE: To review the relationship between congenital heart defects and chromosomal abnormalities detected by the karyotype. DATA SOURCES: Scientific articles were searched in MEDLINE database, using the descriptors "karyotype" OR "chromosomal" OR "chromosome" AND "heart defects, congenital". The research was limited to articles published in English from 1980 on. DATA SYNTHESIS: Congenital heart disease is characterized by an etiologically heterogeneous and not well understood group of lesions. Several researchers have evaluated the presence of chromosomal abnormalities detected by the karyotype in patients with congenital heart disease. However, most of the articles were retrospective studies developed in Europe and only some of the studied patients had a karyotype exam. In this review, only one study was conducted in Latin America, in Brazil. It is known that chromosomal abnormalities are frequent, being present in about one in every ten patients with congenital heart disease. Among the karyotype alterations in these patients, the most important is the trisomy 21 (Down syndrome). These patients often have associated extra-cardiac malformations, with a higher risk of morbidity and mortality, which makes heart surgery even more risky. CONCLUSIONS: Despite all the progress made in recent decades in the field of cytogenetic, the karyotype remains an essential tool in order to evaluate patients with congenital heart disease. The detailed dysmorphological physical examination is of great importance to indicate the need of a karyotype. PMID:25119760

  6. Effects of exercise training on pulmonary vessel muscularization and right ventricular function in an animal model of COPD.

    Science.gov (United States)

    Hassel, Erlend; Berre, Anne Marie; Skjulsvik, Anne Jarstein; Steinshamn, Sigurd

    2014-09-28

    Right ventricular dysfunction in COPD is common, even in the absence of pulmonary hypertension. The aim of the present study was to examine the effects of high intensity interval training (HIIT) on right ventricular (RV) function, as well as pulmonary blood vessel remodeling in a mouse model of COPD. 42 female A/JOlaHsd mice were randomized to exposure to either cigarette smoke or air for 6 hours/day, 5 days/week for 14 weeks. Mice from both groups were further randomized to sedentariness or HIIT for 4 weeks. Cardiac function was evaluated by echocardiography and muscularization of pulmonary vessel walls by immunohistochemistry. Smoke exposure induced RV systolic dysfunction demonstrated by reduced tricuspid annular plane systolic excursion. HIIT in smoke-exposed mice reversed RV dysfunction. There were no significant effects on the left ventricle of neither smoke exposure nor HIIT. Muscularization of the pulmonary vessels was reduced after exercise intervention, but no significant effects on muscularization were observed from smoke exposure. RV function was reduced in mice exposed to cigarette smoke. No Increase in pulmonary vessel muscularization was observed in these mice, implying that other mechanisms caused the RV dysfunction. HIIT attenuated the RV dysfunction in the smoke exposed mice. Reduced muscularization of the pulmonary vessels due to HIIT suggests that exercise training not only affects the heart muscle, but also has important effects on the pulmonary vasculature.

  7. Flexible Composite-Material Pressure Vessel

    Science.gov (United States)

    Brown, Glen; Haggard, Roy; Harris, Paul A.

    2003-01-01

    A proposed lightweight pressure vessel would be made of a composite of high-tenacity continuous fibers and a flexible matrix material. The flexibility of this pressure vessel would render it (1) compactly stowable for transport and (2) more able to withstand impacts, relative to lightweight pressure vessels made of rigid composite materials. The vessel would be designed as a structural shell wherein the fibers would be predominantly bias-oriented, the orientations being optimized to make the fibers bear the tensile loads in the structure. Such efficient use of tension-bearing fibers would minimize or eliminate the need for stitching and fill (weft) fibers for strength. The vessel could be fabricated by techniques adapted from filament winding of prior composite-material vessels, perhaps in conjunction with the use of dry film adhesives. In addition to the high-bias main-body substructure described above, the vessel would include a low-bias end substructure to complete coverage and react peak loads. Axial elements would be overlaid to contain damage and to control fiber orientation around side openings. Fiber ring structures would be used as interfaces for connection to ancillary hardware.

  8. Ionizing radiations and blood vessels

    International Nuclear Information System (INIS)

    Vorob'ev, E.I.; Stepanov, R.P.

    1985-01-01

    Data on phenomeology of radiation changes of blood vessels are systemized and the authors' experience is generalyzed. A critical analysis of modern conceptions on processes resulting in vessel structure damage after irradiation, is given. Special attention is paid to reparation and compensation of radiation injury of vessels

  9. Acrylic vessel cleaning tests

    International Nuclear Information System (INIS)

    Earle, D.; Hahn, R.L.; Boger, J.; Bonvin, E.

    1997-01-01

    The acrylic vessel as constructed is dirty. The dirt includes blue tape, Al tape, grease pencil, gemak, the glue or residue form these tapes, finger prints and dust of an unknown composition but probably mostly acrylic dust. This dirt has to be removed and once removed, the vessel has to be kept clean or at least to be easily cleanable at some future stage when access becomes much more difficult. The authors report on the results of a series of tests designed: (a) to prepare typical dirty samples of acrylic; (b) to remove dirt stuck to the acrylic surface; and (c) to measure the optical quality and Th concentration after cleaning. Specifications of the vessel call for very low levels of Th which could come from tape residues, the grease pencil, or other sources of dirt. This report does not address the concerns of how to keep the vessel clean after an initial cleaning and during the removal of the scaffolding. Alconox is recommended as the cleaner of choice. This acrylic vessel will be used in the Sudbury Neutrino Observatory

  10. Development of PWR pressure vessel steels

    International Nuclear Information System (INIS)

    Druce, S.; Edwards, B.

    1982-01-01

    Requirements to be met by vessel steels for pressurized water reactors are analyzed. Chemicat composition of low-alloyed steels, mechanical properties of sheets and forgings made of these steels and changes in the composition and properties over the wall thickness of the reactor vessel are presented. Problems of the vessel manufacturing including welding and heat treatment processes of sheets and forgings are considered. Special attention is paid to steel embrittlement during vessel fabrication and operation (radiation embrittlement, thermal embrittlement). The role of non-metal inclusions and their effect on anisotropy of fracture toughness is discussed. Possible developments of vessel steels and procedures for producing reactor vessels are reviewed

  11. Development of PWR pressure vessel steels

    Energy Technology Data Exchange (ETDEWEB)

    Druce, S.; Edwards, B.

    1982-01-01

    Requirements to be met by vessel steels for pressurized water reactors are analyzed. Chemicat composition of low-alloyed steels, mechanical properties of sheets and forgings made of these steels and changes in the composition and properties over the wall thickness of the reactor vessel are presented. Problems of the vessel manufacturing including welding and heat treatment processes of sheets and forgings are considered. Special attention is paid to steel embrittlement during vessel fabrication and operation (radiation embrittlement, thermal embrittlement). The role of non-metal inclusions and their effect on anisotropy of fracture toughness is discussed. Possible developments of vessel steels and procedures for producing reactor vessels are reviewed.

  12. Clay Corner: Recreating Chinese Bronze Vessels.

    Science.gov (United States)

    Gamble, Harriet

    1998-01-01

    Presents a lesson where students make faux Chinese bronze vessels through slab or coil clay construction after they learn about the history, function, and design of these vessels. Utilizes a variety of glaze finishes in order to give the vessels an aged look. Gives detailed guidelines for creating the vessels. (CMK)

  13. Gammatography of thick lead vessels

    International Nuclear Information System (INIS)

    Raghunath, V.M.; Bhatnagar, P.K.; Sundaram, V.M.

    1979-01-01

    Radiography, scintillation and GM counting and dose measurements using ionisation chamber equipment are commonly used for detecting flaws/voids in materials. The first method is mostly used for steel vessels and to a lesser extent thin lead vessels also and is essentially qualitative. Dose measuring techniques are used for very thick and large lead vessels for which high strength radioactive sources are required, with its inherent handling problems. For vessels of intermediate thicknesses, it is ideal to use a small strength source and a GM or scintillation counter assembly. At the Reactor Research Centre, Kalpakkam, such a system was used for checking three lead vessels of thicknesses varying from 38mm to 65mm. The tolerances specified were +- 4% variation in lead thickness. The measurements also revealed the non concentricity of one vessel which had a thickness varying from 38mm to 44mm. The second vessel was patently non-concentric and the dimensional variation was truly reproduced in the measurements. A third vessel was fabricated with careful control of dimensions and the measurements exhibited good concentricity. Small deviations were observed, attributable to imperfect bondings between steel and lead. This technique has the following advantages: (a) weaker sources used result in less handling problems reducing the personnel exposures considerably; (b) the sensitivity of the instrument is quite good because of better statistics; (c) the time required for scanning a small vessel is more, but a judicious use of a scintillometer for initial fast scan will help in reducing the total scanning time; (d) this method can take advantage of the dimensional variations themselves to get the calibration and to estimate the deviations from specified tolerances. (auth.)

  14. Smooth muscle cell recruitment to lymphatic vessels requires PDGFB and impacts vessel size but not identity.

    Science.gov (United States)

    Wang, Yixin; Jin, Yi; Mäe, Maarja Andaloussi; Zhang, Yang; Ortsäter, Henrik; Betsholtz, Christer; Mäkinen, Taija; Jakobsson, Lars

    2017-10-01

    Tissue fluid drains through blind-ended lymphatic capillaries, via smooth muscle cell (SMC)-covered collecting vessels into venous circulation. Both defective SMC recruitment to collecting vessels and ectopic recruitment to lymphatic capillaries are thought to contribute to vessel failure, leading to lymphedema. However, mechanisms controlling lymphatic SMC recruitment and its role in vessel maturation are unknown. Here, we demonstrate that platelet-derived growth factor B (PDGFB) regulates lymphatic SMC recruitment in multiple vascular beds. PDGFB is selectively expressed by lymphatic endothelial cells (LECs) of collecting vessels. LEC-specific deletion of Pdgfb prevented SMC recruitment causing dilation and failure of pulsatile contraction of collecting vessels. However, vessel remodelling and identity were unaffected. Unexpectedly, Pdgfb overexpression in LECs did not induce SMC recruitment to capillaries. This was explained by the demonstrated requirement of PDGFB extracellular matrix (ECM) retention for lymphatic SMC recruitment, and the low presence of PDGFB-binding ECM components around lymphatic capillaries. These results demonstrate the requirement of LEC-autonomous PDGFB expression and retention for SMC recruitment to lymphatic vessels, and suggest an ECM-controlled checkpoint that prevents SMC investment of capillaries, which is a common feature in lymphedematous skin. © 2017. Published by The Company of Biologists Ltd.

  15. Compartment analysis of 125I-labelled albumin washout from coronary vessels of isolated perfused hearts

    International Nuclear Information System (INIS)

    Cheng Eap Ng; Seh-Hoon Song

    1978-01-01

    Albumin labelled with 125 I was used as a tracer to investigate the washout kinetics of plasma from the coronary circulation of isolated perfused feline hearts. Compartmentalization with experimental results showed at least two compartments. The model was compared with a three-compartment model found previously for red blood cells. The results indicate that there is a separation of plasma and RBC in the coronary microcirculation. (author)

  16. Quantification of pulmonary thallium-201 activity after upright exercise in normal persons: importance of peak heart rate and propranolol usage in defining normal values

    International Nuclear Information System (INIS)

    Brown, K.A.; Boucher, C.A.; Okada, R.D.; Strauss, H.W.; Pohost, G.M.

    1984-01-01

    Fifty-nine normal patients (34 angiographically normal and 25 clinically normal by Bayesian analysis) underwent thallium-201 imaging after maximal upright exercise. Lung activity was quantitated relative to myocardial activity and a lung/myocardial activity ratio was determined for each patient. Stepwise regression analysis was then used to examine the influence of patient clinical characteristics and exercise variables on the lung/myocardium ratio. Peak heart rate during exercise and propranolol usage both showed significant negative regression coefficients (p less than 0.001). No other patient data showed a significant relation. Using the regression equation and the estimated variance, a 95% confidence level upper limit of normal could be determined for a give peak heart rate and propranolol status. Sixty-one other patients were studied to validate the predicted upper limits of normal based on this model. None of the 27 patients without coronary artery disease had an elevated lung/myocardial ratio, compared with 1 of 8 with 1-vessel disease (difference not significant), 6 of 14 with 2-vessel disease (p less than 0.005), and 6 of 12 with 3-vessel disease (p less than 0.0001). Thus, lung activity on upright exercise thallium-201 studies can be quantitated relative to myocardial activity, and is inversely related to peak heart rate and propranolol use. Use of a regression analysis allows determination of a 95% confidence upper limit of normal to be anticipated in an individual patient

  17. VESsel GENeration Analysis (VESGEN): Innovative Vascular Mappings for Astronaut Exploration Health Risks and Human Terrestrial Medicine

    Science.gov (United States)

    Parsons-Wingerter, Patricia; Kao, David; Valizadegan, Hamed; Martin, Rodney; Murray, Matthew C.; Ramesh, Sneha; Sekaran, Srinivaas

    2017-01-01

    Currently, astronauts face significant health risks in future long-duration exploration missions such as colonizing the Moon and traveling to Mars. Numerous risks include greatly increased radiation exposures beyond the low earth orbit (LEO) of the ISS, and visual and ocular impairments in response to microgravity environments. The cardiovascular system is a key mediator in human physiological responses to radiation and microgravity. Moreover, blood vessels are necessarily involved in the progression and treatment of vascular-dependent terrestrial diseases such as cancer, coronary vessel disease, wound-healing, reproductive disorders, and diabetes. NASA developed an innovative, globally requested beta-level software, VESsel GENeration Analysis (VESGEN) to map and quantify vascular remodeling for application to astronaut and terrestrial health challenges. VESGEN mappings of branching vascular trees and networks are based on a weighted multi-parametric analysis derived from vascular physiological branching rules. Complex vascular branching patterns are determined by biological signaling mechanisms together with the fluid mechanics of multi-phase laminar blood flow.

  18. Americium behaviour in plastic vessels

    Energy Technology Data Exchange (ETDEWEB)

    Legarda, F.; Herranz, M. [Departamento de Ingenieria Nuclear y Mecanica de Fluidos, Escuela Tecnica Superior de Ingenieria de Bilbao, Universidad del Pais Vasco (UPV/EHU), Alameda de Urquijo s/n, 48013 Bilbao (Spain); Idoeta, R., E-mail: raquel.idoeta@ehu.e [Departamento de Ingenieria Nuclear y Mecanica de Fluidos, Escuela Tecnica Superior de Ingenieria de Bilbao, Universidad del Pais Vasco (UPV/EHU), Alameda de Urquijo s/n, 48013 Bilbao (Spain); Abelairas, A. [Departamento de Ingenieria Nuclear y Mecanica de Fluidos, Escuela Tecnica Superior de Ingenieria de Bilbao, Universidad del Pais Vasco (UPV/EHU), Alameda de Urquijo s/n, 48013 Bilbao (Spain)

    2010-07-15

    The adsorption of {sup 241}Am dissolved in water in different plastic storage vessels was determined. Three different plastics were investigated with natural and distilled waters and the retention of {sup 241}Am by these plastics was studied. The same was done by varying vessel agitation time, vessel agitation speed, surface/volume ratio of water in the vessels and water pH. Adsorptions were measured to be between 0% and 70%. The adsorption of {sup 241}Am is minimized with no water agitation, with PET or PVC plastics, and by water acidification.

  19. Americium behaviour in plastic vessels

    International Nuclear Information System (INIS)

    Legarda, F.; Herranz, M.; Idoeta, R.; Abelairas, A.

    2010-01-01

    The adsorption of 241 Am dissolved in water in different plastic storage vessels was determined. Three different plastics were investigated with natural and distilled waters and the retention of 241 Am by these plastics was studied. The same was done by varying vessel agitation time, vessel agitation speed, surface/volume ratio of water in the vessels and water pH. Adsorptions were measured to be between 0% and 70%. The adsorption of 241 Am is minimized with no water agitation, with PET or PVC plastics, and by water acidification.

  20. PWR vessel flaw distribution development

    International Nuclear Information System (INIS)

    Rosinski, S.T.; Kennedy, E.L.; Foulds, J.R.; Kinsman, K.M.

    1990-01-01

    This paper reports on PWR pressure vessels which operate under NRC rules and regulatory guides intended to prevent failure of the vessels. Plants failing to meet the operating criteria specified under these rules and regulations are required to analytically demonstrate fitness for service in order to continue operation. The initial flaw size or distribution of initial vessel flaws is a key input to the required vessel integrity analyses. However, the flaw distribution assumed in the development of the NRC Regulations and recommended for the plant specific analyses is potentially over-conservative. This is because the distribution is based on the limited amount of vessel inspection data available at the time the criteria were being developed and does not take full advantage of the more recent and reliable domestic vessel inspection results. The U.S. Department of Energy is funding an effort through Sandia National Laboratories to investigate the possibility of developing a new flaw distribution based on the increased amount and improved reliability of domestic vessel inspection data. Results of Phase I of the program indicate that state-of-the-art NDE systems' capabilities are sufficient for development of a new flaw distribution that could ultimately provide life extension benefits over the presently required operating practice

  1. Test of 6-in.-thick pressure vessels. Series 3: intermediate test vessel V-7

    International Nuclear Information System (INIS)

    Merkle, J.G.; Robinson, G.C.; Holz, P.P.; Smith, J.E.; Bryan, R.H.

    1976-08-01

    The test of intermediate test vessel V-7 was a crack-initiation fracture test of a 152-mm-thick (6-in.), 990-mm-OD (39-in.) vessel of ASTM A533, grade B, class 1 steel plate with a sharp outside surface flaw 457 mm (18 in.) long and about 135 mm (5.3 in.) deep. The vessel was heated to 91 0 C (196 0 F) and pressurized hydraulically until leakage through the flaw terminated the test at a peak pressure of 147 MPa (21,350 psi). Fracture toughness data obtained by testing precracked Charpy-V and compact-tension specimens machined from a prolongation of the cylindrical test shell were used in pretest analyses of the flawed vessel. The vessel, as expected, did not burst. Upon depressurization, the ruptured ligament closed so as to maintain static pressure without leakage at about 129 MPa

  2. Modification method to reduce the impact of blood vessel on noncontact discrimination of human blood based on ;M+N; theory

    Science.gov (United States)

    Zhang, Linna; Ding, Hongyan; Lin, Ling; Wang, Yimin; Guo, Xin

    2018-01-01

    Noncontact discriminating human blood is significantly crucial for import-export ports and inspection and quarantine departments. We had already demonstrated that visible diffuse reflectance spectroscopy combining PLS-DA method can successfully realize noncontact human blood discrimination. However, the circulated blood vessels may be produced with different materials. The use of various kinds of blood tubes may have a negative effect on the discrimination, based on ;M+N; theory (Li et al., 2016). In this research, we explored the impact of different material of blood vessels, such as glass tube and plastic tube, on the prediction ability of the discrimination model. Furthermore, we searched for the modification method to reduce the influence from the blood tubes. Our work indicated that generalized diffuse reflectance method can greatly improve the discrimination accuracy. This research can greatly facilitate the application of noncontact discrimination method based on visible and near-infrared diffuse reflectance spectroscopy.

  3. Improved vessel morphology measurements in contrast-enhanced multi-detector computed tomography coronary angiography with non-linear post-processing

    International Nuclear Information System (INIS)

    Ferencik, Maros; Lisauskas, Jennifer B.; Cury, Ricardo C.; Hoffmann, Udo; Abbara, Suhny; Achenbach, Stephan; Karl, W. Clem; Brady, Thomas J.; Chan, Raymond C.

    2006-01-01

    Multi-detector computed tomography (MDCT) permits detection of coronary plaque. However, noise and blurring impair accuracy and precision of plaque measurements. The aim of the study was to evaluate MDCT post-processing based on non-linear image deblurring and edge-preserving noise suppression for measurements of plaque size. Contrast-enhanced MDCT coronary angiography was performed in four subjects (mean age 55 ± 5 years, mean heart rate 54 ± 5 bpm) using a 16-slice scanner (Siemens Sensation 16, collimation 16 x 0.75 mm, gantry rotation 420 ms, tube voltage 120 kV, tube current 550 mAs, 80 mL of contrast). Intravascular ultrasound (IVUS; 40 MHz probe) was performed in one vessel in each patient and served as a reference standard. MDCT vessel cross-sectional images (1 mm thickness) were created perpendicular to centerline and aligned with corresponding IVUS images. MDCT images were processed using a deblurring and edge-preserving noise suppression algorithm. Then, three independent blinded observers segmented lumen and outer vessel boundaries in each modality to obtain vessel cross-sectional area and wall area in the unprocessed MDCT cross-sections, post-processed MDCT cross-sections and corresponding IVUS. The wall area measurement difference for unprocessed and post-processed MDCT images relative to IVUS was 0.4 ± 3.8 mm 2 and -0.2 ± 2.2 mm 2 (p 2 , respectively. In conclusion, MDCT permitted accurate in vivo measurement of wall area and vessel cross-sectional area as compared to IVUS. Post-processing to reduce blurring and noise reduced variability of wall area measurements and reduced measurement bias for both wall area and vessel cross-sectional area

  4. Hydrogen storage in insulated pressure vessels

    Energy Technology Data Exchange (ETDEWEB)

    Aceves, S.M.; Garcia-Villazana, O. [Lawrence Livermore National Lab., CA (United States)

    1998-08-01

    Insulated pressure vessels are cryogenic-capable pressure vessels that can be fueled with liquid hydrogen (LH{sub 2}) or ambient-temperature compressed hydrogen (CH{sub 2}). Insulated pressure vessels offer the advantages of liquid hydrogen tanks (low weight and volume), with reduced disadvantages (lower energy requirement for hydrogen liquefaction and reduced evaporative losses). This paper shows an evaluation of the applicability of the insulated pressure vessels for light-duty vehicles. The paper shows an evaluation of evaporative losses and insulation requirements and a description of the current analysis and experimental plans for testing insulated pressure vessels. The results show significant advantages to the use of insulated pressure vessels for light-duty vehicles.

  5. The death of great ships : photography, politics, and waste in the global imaginary.

    OpenAIRE

    Crang, M.

    2010-01-01

    The iconic images heralding an age of connectivity are the plane and the trace of digital flows bearing information. However, not far behind has been the cumbrous yet essential 'big box' of containerisation, shipping all manner of goods across the planet on great vessels remorselessly circling the globe. Critiques of global trade have latched upon the counter image of these mighty ships' ruinous carcasses beached and being broken in South Asia. Here then is the antipode of globalisation - shi...

  6. Pressure vessel for nuclear reactors

    International Nuclear Information System (INIS)

    1975-01-01

    The invention applies to a pressure vessel for nuclear reactors whose shell, made of cast metal segments, has a steel liner. This liner must be constructed to withstand all operational stresses and to be easily repairable. The invention solves this problem by installing the liner at a certain distance from the inner wall of the pressure vessel shell and by filling this clearance with supporting concrete. Both the concrete and the steel liner must have a lower prestress than the pressure vessel shell. In order to avoid damage to the liner when prestressing the pressure vessel shell, special connecting elements are provided which consist of welded-on fastening elements projecting into recesses in the cast metal segments of the pressure vessel. Their design is described in detail. (TK) [de

  7. Safety vessels for explosive fusion reactor

    International Nuclear Information System (INIS)

    Mineev, V.

    1994-01-01

    The failure of several types of geometrically similar cylindrical and spherical steel and glass fibers vessels filled with water or air was investigated when an explosive charge of TNT was detonated in the center. Vessels had radius 50-1000 mm, thickness of walls 2-20%. The detonation on TNT imitated energy release. The parameter: K = M/mf is a measure of the strength of the vessel where M is the mass of the vessel, and mf is the mass of TNT for which the vessel fails. This demanded 2-4 destroyed and nondestroyed shots. It may be showed that: K=A/σ f where σ f is the fracture stress of the material vessel, and A = const = F(energy TNT, characteristic of elasticity of vessel material). The chief results are the following: (1) A similar increase in the geometrical dimensions of steel vessels by a factor of 10 leads to the increase of parameter K in about 5 times and to decrease of failure deformation in 7 times (scale effect). (2) For glass fibers, scale effect is absent. (3) This problem is solved in terms of theory energetic scale effect. (4) The concept of TNT equivalent explosive makes it possible to use these investigations to evaluate the response of safety vessels for explosive fusion reactor

  8. Radioactive waste processing vessel

    International Nuclear Information System (INIS)

    Hayashi, Masaru; Suzuki, Osamu; Ishizaki, Kanjiro.

    1987-01-01

    Purpose: To obtain a vessel of a reduced weight and with no external leaching of radioactive materials. Constitution: The vessel main body is constituted, for example, with light weight concretes or foamed concretes, particularly, foamed concretes containing fine closed bubbles in the inside. Then, layers having dense texture made of synthetic resin such as polystylene, vinylchloride resin, etc. or metal plate such as stainless plate are integrally disposed to the inner surface of the vessel main body. The cover member also has the same structure. (Sekiya, K.)

  9. Ionizing radiations and blood vessels

    International Nuclear Information System (INIS)

    Vorob'ev, E.I.; Stepanov, R.P.

    1985-01-01

    Data on phenomenology of radiation-induced changes in blood vessels are systematized and authors' experience is generalized. Modern concepts about processes leading to vessel structure injury after irradiation is critically analyzed. Special attention is paid to reparation and compensation of X-ray vessel injury, consideration of which is not yet sufficiently elucidated in literature

  10. Heart Development, Diseases, and Regeneration - New Approaches From Innervation, Fibroblasts, and Reprogramming.

    Science.gov (United States)

    Ieda, Masaki

    2016-09-23

    It is well known that cardiac function is tightly controlled by neural activity; however, the molecular mechanism of cardiac innervation during development and the relationship with heart disease remain undetermined. My work has revealed the molecular networks that govern cardiac innervation and its critical roles in heart diseases such as silent myocardial ischemia and arrhythmias. Cardiomyocytes proliferate during embryonic development, but lose their proliferative capacity after birth. Cardiac fibroblasts are a major source of cells during fibrosis and induce cardiac hypertrophy after myocardial injury in the adult heart. Despite the importance of fibroblasts in the adult heart, the role of fibroblasts in embryonic heart development was previously not determined. I demonstrated that cardiac fibroblasts play important roles in myocardial growth and cardiomyocyte proliferation during embryonic development, and I identified key paracrine factors and signaling pathways. In contrast to embryonic cardiomyocytes, adult cardiomyocytes have little regenerative capacity, leading to heart failure and high mortality rates after myocardial infarction. Leveraging the knowledge of developmental biology, I identified cardiac reprogramming factors that can directly convert resident cardiac fibroblasts into cardiomyocytes for heart regeneration. These findings greatly improved our understanding of heart development and diseases, and provide a new strategy for heart regenerative therapy. (Circ J 2016; 80: 2081-2088).

  11. Doppler ultrasound evaluation of cerebral blood flow pattern in neonates with congenital heart disease

    International Nuclear Information System (INIS)

    Kim, Tae Hoon; Kim, Mi Young; Kim, Yang Min; Lee, Soo Hyun; Kim, Soo Jin; Kim, Woong Han

    2003-01-01

    To evaluate intracerebral resistive index (RI) values in neonates with congenital heart disease and to investigate their changes after the corrective surgery of the congenital heart disease. Sixty nine neonates with congenital heart disease who underwent brain ultrasonography were included. Resistive index values were obtained at the genu portion of the anterior cerebral arteries through the anterior fontanelles. The patients were divided into 4 groups according to the presence of associated patent ductus arteriosus (PDA) and intracranial RI values. We evaluated the types of congenital heart disease that could influence RI values. Resistive index values were statistically higher in patients with PDA than in patients without PDA (p<0.05). RI values were higher in cases of large PDA with left-to-right shunt, but within the normal range in cases of small or nearly closing PDA or large PDA with bidirectional blood flow or with right-to-left shunt. For those patients without PDA, RI values were higher when patients had pulmonary atresia with multiple collateral vessels into the lung or when truncus arteriosus was present. RI values were also high in patients with hypoplastic left heart syndrome. RI values were normalized after the ligation of PDA, but patients with hypoplastic left heart syndrome showed persistently high RI values even after the Norwood's operation with Blalock-Taussig shunt. RI values are influenced by various congenital heart diseases except PDA. Therefore, the presences of the congenital heart disease and its hemodynamic changes should be taken into consideration in the evaluation of the intracranial RI values using Doppler ultrasonography.

  12. Spectrum of Congenital Heart Diseases in Eastern Nepal: A tertiary care hospital experience

    Directory of Open Access Journals (Sweden)

    Prashant Shah

    2017-01-01

    Full Text Available Background & Objectives: Congenital heart diseases are neglected especially in world’s poorest nations and appear to be ignored and unexplored dimension of health. The exact prevalence and spectrum of congenital heart diseases in Nepal is largely unknown. The aim of this study was to describe the local experience on the magnitude and the pattern of congenital heart disease in order to increase the awareness of the public and health policy makers on its burden in Nepal.Materials & Methods: This is an observational hospital based study carried out in a tertiary care hospital in Eastern Nepal. The duration of this study was from April 2015 to July 2016. The echocardiography reports of all patients clinically suspected of having congenital heart disease were retrieved, and their diagnostic details were extracted. Only patients of day one of life to 14 years of age were included. Congenital heart diseases like bicuspid aortic valve, mitral valve prolapse and various inherited cardiomyopathies were excluded.Results: A total of 330 echocardiograms were performed for clinically suspected congenital heart disease.  The mean age of study population was 22.31±34.08 months with male to female ratio of 1.2:1. 23% of clinically suspected congenital heart disease cases turned out to have normal echocardiography. Acyanotic congenital heart disease was most common (81.5% followed by cyanotic congenital heart disease (14.2% and obstructive congenital heart disease (4.3%. Atrial septal defect was found to be the most common form of acyanotic congenital heart disease (52% which was followed by ventricular septal defect (28.8% and patent ductus arteriosus (14.8%. Tetralogy of Fallot and double outlet right ventricle were the most common form of cyanotic CHD representing 44.4% of all cyanotic patients. Pulmonary stenosis was the most common obstructive congenital heart disease observed in this study population (63.6%. Rarer entities, like d-transposition of great

  13. Clinical results of single-vessel versus multiple-vessel infrapopliteal intervention

    OpenAIRE

    Darling, Jeremy; McCallum, John C.; Soden, Peter A.; Hon, J.J. (John J.); Guzman, R.J. (Raul J.); Wyers, M.C. (Mark C.); Verhagen, Hence; Schermerhorn, Marc

    2016-01-01

    textabstractObjective The effects of concomitant endovascular interventions on multiple infrapopliteal vessels are not well known, and the short-term and long-term sequelae of such procedures have not been reported. Methods From 2004 to 2014, 673 limbs in 528 patients underwent an infrapopliteal endovascular intervention for tissue loss (77%), rest pain (13%), stenosis of a previously treated vessel (5%), acute limb ischemia (3%), or claudication (2%). Outcomes included wound healing, RAS eve...

  14. Molten material-containing vessel

    International Nuclear Information System (INIS)

    Akagawa, Katsuhiko

    1998-01-01

    The molten material-containing vessel of the present invention comprises a vessel main body having an entrance opened at the upper end, a lid for closing the entrance, an outer tube having an upper end disposed at the lower surface of the lid, extended downwardly and having an closed lower end and an inner tube disposed coaxially with the outer tube. When a molten material is charged from the entrance to the inside of the vessel main body of the molten material-containing vessel and the entrance is closed by the lid, the outer tube and the inner tube are buried in the molten material in the vessel main body, accordingly, a fluid having its temperature elevated by absorption of the heat of the molten material rises along the inner circumferential surface of the outer tube, abuts against the lower surface of the lid and cooled by exchanging heat with the lid and forms a circulating flow. Since the heat in the molten material is continuously absorbed by the fluid, transferred to the lid and released from the lid to the atmospheric air, heat releasing efficiency can be improved compared with conventional cases. (N.H.)

  15. Study on severe fuel damage and in-vessel melt progression

    International Nuclear Information System (INIS)

    Kim, Hee Dong; Kim, Sang Baik; Lee, Gyu Jung

    1992-06-01

    In-vessel core melt progression describes the progression of the state of a reactor core from core uncovery up to reactor vessel melt through in uncovered accidents or through temperature stabilization in accidents recovered by core reflooding. Melt progression can be thought as two parts; early melt progression and late melt progression. Early phase of core melt progression includes the progression of core material melting and relocation, which mostly consist of metallic materials. On the other hand, the late phase of core melt progression involves ceramic material melt and relocation to the lower plenum and heat-up the reactor vessel lower head. A large number of information are available for the early melt progression through experiments such as SFD, DF, FLHT test and utilized in the severe accident analysis codes. However, understanding of the late phase melt progression phenomenology is based primary on TMI-2 core examinations and not much experimental information is available. Especilally, the great uncertainties exist in vessel failure mode, melt composition, mass, and temperature. Further research is planned to perform to reduce the uncertainties in understanding of core melt down accidents as parts of long term melt progression research program. A study on the core melt progression at KAERI has been being performed through the Severe Accident Research Program with USNRC. KAERI staff had participated in the PBF SFD experiments at INEL and analyses of experiments were performed using SCDAP code. Experiments of core melt program have not been carried out at KAERI yet. It is planned that further research on core melt down accidents will be performed, which is related to design of future generations of nuclear reactors as parts of long-term project for improvement of nuclear reactor safety. (Author)

  16. Soluble Flt-1 links microvascular disease with heart failure in CKD.

    Science.gov (United States)

    Di Marco, Giovana S; Kentrup, Dominik; Reuter, Stefan; Mayer, Anna B; Golle, Lina; Tiemann, Klaus; Fobker, Manfred; Engelbertz, Christiane; Breithardt, Günter; Brand, Eva; Reinecke, Holger; Pavenstädt, Hermann; Brand, Marcus

    2015-05-01

    Chronic kidney disease (CKD) is associated with an increased risk of heart failure (HF). Elevated plasma concentrations of soluble Flt-1 (sFlt-1) have been linked to cardiovascular disease in CKD patients, but whether sFlt-1 contributes to HF in CKD is still unknown. To provide evidence that concludes a pathophysiological role of sFlt-1 in CKD-associated HF, we measured plasma sFlt-1 concentrations in 586 patients with angiographically documented coronary artery disease and renal function classified according to estimated glomerular filtration rate (eGFR). sFlt-1 concentrations correlated negatively with eGFR and were associated with signs of heart failure, based on New York Heart Association functional class and reduced left ventricular ejection fraction (LVEF), and early mortality. Additionally, rats treated with recombinant sFlt-1 showed a 15 % reduction in LVEF and a 29 % reduction in cardiac output compared with control rats. High sFlt-1 concentrations were associated with a 15 % reduction in heart capillary density (number of vessels/cardiomyocyte) and a 24 % reduction in myocardial blood volume. Electron microscopy and histological analysis revealed mitochondrial damage and interstitial fibrosis in the hearts of sFlt-1-treated, but not control rats. In 5/6-nephrectomised rats, an animal model of CKD, sFlt-1 antagonism with recombinant VEGF121 preserved heart microvasculature and significantly improved heart function. Overall, these findings suggest that a component of cardiovascular risk in CKD patients could be directly attributed to sFlt-1. Assessment of patients with CKD confirmed that sFlt-1 concentrations were inversely correlated with renal function, while studies in rats suggested that sFlt-1 may link microvascular disease with HF in CKD.

  17. Americium behaviour in plastic vessels.

    Science.gov (United States)

    Legarda, F; Herranz, M; Idoeta, R; Abelairas, A

    2010-01-01

    The adsorption of (241)Am dissolved in water in different plastic storage vessels was determined. Three different plastics were investigated with natural and distilled waters and the retention of (241)Am by these plastics was studied. The same was done by varying vessel agitation time, vessel agitation speed, surface/volume ratio of water in the vessels and water pH. Adsorptions were measured to be between 0% and 70%. The adsorption of (241)Am is minimized with no water agitation, with PET or PVC plastics, and by water acidification. Copyright 2009 Elsevier Ltd. All rights reserved.

  18. Mutation of p107 exacerbates the consequences of Rb loss in embryonic tissues and causes cardiac and blood vessel defects.

    Science.gov (United States)

    Berman, Seth D; West, Julie C; Danielian, Paul S; Caron, Alicia M; Stone, James R; Lees, Jacqueline A

    2009-09-01

    The retinoblastoma tumor-suppressor protein, pRb, is a member of the pocket protein family that includes p107 and p130. These proteins have well-defined roles in regulating entry into and exit from the cell cycle and also have cell cycle-independent roles in facilitating differentiation. Here we investigate the overlap between pocket protein's function during embryonic development by using conditional mutant alleles to generate Rb;p107 double-mutant embryos (DKOs) that develop in the absence of placental defects. These DKOs die between e13.5 and e14.5, much earlier than either the conditional Rb or the germline p107 single mutants, which survive to birth or are largely viable, respectively. Analyses of the e13.5 DKOs shows that p107 mutation exacerbates the phenotypes resulting from pRb loss in the central nervous system and lens, but not in the peripheral nervous system. In addition, these embryos exhibit novel phenotypes, including increased proliferation of blood vessel endothelial cells, and heart defects, including double-outlet right ventricle (DORV). The DORV is caused, at least in part, by a defect in blood vessel endothelial cells and/or heart mesenchymal cells. These findings demonstrate novel, overlapping functions for pRb and p107 in numerous murine tissues.

  19. Total Artificial Heart Bridge to Transplantation for a Patient With Occult Intracardiac Malignancy: Case Report.

    Science.gov (United States)

    Reich, H; Czer, L; Bannykh, S; De Robertis, M; Wolin, E; Amersi, F; Moriguchi, J; Kobashigawa, J; Arabia, F

    2015-09-01

    Malignancy is the leading cause of long-term morbidity and mortality after heart and other solid organ transplantation; therefore, great emphasis is placed on pre- and post-transplantation cancer screening. Even with meticulous screening during evaluation for heart transplant candidacy, an occult cancer may not be apparent. Here, we share the case of a 51-year-old man with refractory heart failure who underwent total artificial heart implantation as a bridge to transplantation with the surprise finding of an isolated deposit of metastatic carcinoid tumor nested within a left ventricular papillary muscle in his explanted heart. The primary ileal carcinoid tumor was identified and resected completely. After remaining cancer-free for 14 months, he was listed for heart transplantation and was transplanted 2 months later. He is currently 3.5 months out from heart transplantation and doing well, without evidence of recurring malignancy. Copyright © 2015 Elsevier Inc. All rights reserved.

  20. Vessel Sampling and Blood Flow Velocity Distribution With Vessel Diameter for Characterizing the Human Bulbar Conjunctival Microvasculature.

    Science.gov (United States)

    Wang, Liang; Yuan, Jin; Jiang, Hong; Yan, Wentao; Cintrón-Colón, Hector R; Perez, Victor L; DeBuc, Delia C; Feuer, William J; Wang, Jianhua

    2016-03-01

    This study determined (1) how many vessels (i.e., the vessel sampling) are needed to reliably characterize the bulbar conjunctival microvasculature and (2) if characteristic information can be obtained from the distribution histogram of the blood flow velocity and vessel diameter. Functional slitlamp biomicroscope was used to image hundreds of venules per subject. The bulbar conjunctiva in five healthy human subjects was imaged on six different locations in the temporal bulbar conjunctiva. The histograms of the diameter and velocity were plotted to examine whether the distribution was normal. Standard errors were calculated from the standard deviation and vessel sample size. The ratio of the standard error of the mean over the population mean was used to determine the sample size cutoff. The velocity was plotted as a function of the vessel diameter to display the distribution of the diameter and velocity. The results showed that the sampling size was approximately 15 vessels, which generated a standard error equivalent to 15% of the population mean from the total vessel population. The distributions of the diameter and velocity were not only unimodal, but also somewhat positively skewed and not normal. The blood flow velocity was related to the vessel diameter (r=0.23, Psampling size of the vessels and the distribution histogram of the blood flow velocity and vessel diameter, which may lead to a better understanding of the human microvascular system of the bulbar conjunctiva.

  1. Thigh circumference and risk of heart disease and premature death

    DEFF Research Database (Denmark)

    Heitmann, Berit L; Frederiksen, Peder

    2009-01-01

    OBJECTIVE: To examine associations between thigh circumference and incident cardiovascular disease and coronary heart disease and total mortality. DESIGN: Prospective observational cohort study with Cox proportional hazards model and restricted cubic splines. SETTING: Random subset of adults...... in Denmark. PARTICIPANTS: 1436 men and 1380 women participating in the Danish MONICA project, examined in 1987-8 for height, weight, and thigh, hip, and waist circumference, and body composition by impedance. MAIN OUTCOME MEASURES: 10 year incidence of cardiovascular and coronary heart disease and 12.5 years...... of follow-up for total death. RESULTS: A small thigh circumference was associated with an increased risk of cardiovascular and coronary heart diseases and total mortality in both men and women. A threshold effect for thigh circumference was evident, with greatly increased risk of premature death below...

  2. Analysis and optimization on in-vessel inspection robotic system for EAST

    International Nuclear Information System (INIS)

    Zhang, Weijun; Zhou, Zeyu; Yuan, Jianjun; Du, Liang; Mao, Ziming

    2015-01-01

    Since China has successfully built her first Experimental Advanced Superconducting TOKAMAK (EAST) several years ago, great interest and demand have been increasing in robotic in-vessel inspection/operation systems, by which an observation of in-vessel physical phenomenon, collection of visual information, 3D mapping and localization, even maintenance are to be possible. However, it has been raising many challenges to implement a practical and robust robotic system, due to a lot of complex constraints and expectations, e.g., high remanent working temperature (100 °C) and vacuum (10"−"3 pa) environment even in the rest interval between plasma discharge experiments, close-up and precise inspection, operation efficiency, besides a general kinematic requirement of D shape irregular vessel. In this paper we propose an upgraded robotic system with redundant degrees of freedom (DOF) manipulator combined with a binocular vision system at the tip and a virtual reality system. A comprehensive comparison and discussion are given on the necessity and main function of the binocular vision system, path planning for inspection, fast localization, inspection efficiency and success rate in time, optimization of kinematic configuration, and the possibility of underactuated mechanism. A detailed design, implementation, and experiments of the binocular vision system together with the recent development progress of the whole robotic system are reported in the later part of the paper, while, future work and expectation are described in the end.

  3. Stability, structure and scale: improvements in multi-modal vessel extraction for SEEG trajectory planning.

    Science.gov (United States)

    Zuluaga, Maria A; Rodionov, Roman; Nowell, Mark; Achhala, Sufyan; Zombori, Gergely; Mendelson, Alex F; Cardoso, M Jorge; Miserocchi, Anna; McEvoy, Andrew W; Duncan, John S; Ourselin, Sébastien

    2015-08-01

    Brain vessels are among the most critical landmarks that need to be assessed for mitigating surgical risks in stereo-electroencephalography (SEEG) implantation. Intracranial haemorrhage is the most common complication associated with implantation, carrying significantly associated morbidity. SEEG planning is done pre-operatively to identify avascular trajectories for the electrodes. In current practice, neurosurgeons have no assistance in the planning of electrode trajectories. There is great interest in developing computer-assisted planning systems that can optimise the safety profile of electrode trajectories, maximising the distance to critical structures. This paper presents a method that integrates the concepts of scale, neighbourhood structure and feature stability with the aim of improving robustness and accuracy of vessel extraction within a SEEG planning system. The developed method accounts for scale and vicinity of a voxel by formulating the problem within a multi-scale tensor voting framework. Feature stability is achieved through a similarity measure that evaluates the multi-modal consistency in vesselness responses. The proposed measurement allows the combination of multiple images modalities into a single image that is used within the planning system to visualise critical vessels. Twelve paired data sets from two image modalities available within the planning system were used for evaluation. The mean Dice similarity coefficient was 0.89 ± 0.04, representing a statistically significantly improvement when compared to a semi-automated single human rater, single-modality segmentation protocol used in clinical practice (0.80 ± 0.03). Multi-modal vessel extraction is superior to semi-automated single-modality segmentation, indicating the possibility of safer SEEG planning, with reduced patient morbidity.

  4. Autonomic regulation in fetuses with congenital heart disease.

    Science.gov (United States)

    Siddiqui, Saira; Wilpers, Abigail; Myers, Michael; Nugent, J David; Fifer, William P; Williams, Ismée A

    2015-03-01

    Exposure to antenatal stressors affects autonomic regulation in fetuses. Whether the presence of congenital heart disease (CHD) alters the developmental trajectory of autonomic regulation is not known. This prospective observational cohort study aimed to further characterize autonomic regulation in fetuses with CHD; specifically hypoplastic left heart syndrome (HLHS), transposition of the great arteries (TGA), and tetralogy of Fallot (TOF). From 11/2010 to 11/2012, 92 fetuses were enrolled: 41 controls and 51 with CHD consisting of 19 with HLHS, 12 with TGA, and 20 with TOF. Maternal abdominal fetal electrocardiogram (ECG) recordings were obtained at 3 gestational ages: 19-27 weeks (F1), 28-33 weeks (F2), and 34-38 weeks (F3). Fetal ECG was analyzed for mean heart rate along with 3 measures of autonomic variability of the fetal heart rate: interquartile range, standard deviation, and root mean square of the standard deviation of the heart rate (RMSSD), a measure of parasympathetic activity. During F1 and F2 periods, HLHS fetuses demonstrated significantly lower mean HR than controls (pHeart rate variability at F3, as measured by standard deviation, interquartile range, and RMSSD was lower in HLHS than controls (p<0.05). Other CHD subgroups showed a similar, though non-significant trend towards lower variability. Autonomic regulation in CHD fetuses differs from controls, with HLHS fetuses most markedly affected. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Influence of heart rate on diagnostic accuracy and image quality of 16-slice CT coronary angiography: comparison of multisegment and halfscan reconstruction approaches

    International Nuclear Information System (INIS)

    Dewey, Marc; Teige, Florian; Hamm, Bernd; Laule, Michael

    2007-01-01

    The lower the heart rate the better image quality in multislice computed tomography (MSCT) coronary angiography. We prospectively assessed the influence of heart rate on per-patient diagnostic accuracy and image quality of MSCT coronary angiography and compared adaptive multisegment and standard halfscan reconstruction. A consecutive cohort of 126 patients scheduled to undergo conventional coronary angiography was examined with 16-slice CT. For all heart rate groups, per-patient diagnostic accuracy was significantly higher for multisegment than halfscan reconstruction with values of 95 vs. 79% (p 74 bpm, 41 patients). Differences in diagnostic accuracy between adjacent heart rate groups were only significant for halfscan reconstruction for the comparison between the 65-74 and >74 bpm group (p < 0.05). The vessel lengths free of motion artifacts were significantly longer with multisegment reconstruction in all heart rate groups and for all coronary arteries (p < 0.005). For noninvasive MSCT coronary angiography, both per-patient diagnostic accuracy and image quality decline with increasing heart rate, and multisegment reconstruction at high heart rates yields similar results as standard halfscan reconstruction at low heart rates. (orig.)

  6. Central nervous system granulomastous phlebitis with limited extracranial involvement of the heart and lungs: An autopsy case.

    Science.gov (United States)

    Mlakar, Jernej; Zorman, Jerneja Videčnik; Matičič, Mojca; Vrabec, Matej; Alibegović, Armin; Popović, Mara

    2016-02-01

    Primary angiitis of the central nervous system is a rare condition, usually with an insidious onset. There is a wide variety of histological types (granulomatous, lymphocytic or necrotizing vasculitis) and types of vessel involved (arteries, veins or both). Most cases are idiopathic. We describe a first case of idiopathic granulomatous central nervous system phlebitis with additional limited involvement of the heart and lung, exclusively affecting small and medium sized veins in a 22-year-old woman, presenting as a sub acute headache. The reasons for this peculiar limitation of inflammation to the veins and the involvement of the heart and lungs are unknown. © 2015 Japanese Society of Neuropathology.

  7. Radiation embrittlement of PWR vessel supports

    International Nuclear Information System (INIS)

    Cheverton, R.D.; Robinson, G.C.; Pennell, W.E.; Nanstad, R.K.

    1989-01-01

    Several studies pertaining to radiation damage of PWR vessel supports were conducted between 1978 and 1987. During this period, apparently there was no reason to believe that low-temperature (<100 degree C) MTR embrittlement data were not appropriate for evaluating embrittlement of PWR vessel supports. However, late in 1986, data from the High Flux Isotope Reactor (HFIR) vessel surveillance program indicated that the embrittlement rates of the several HFIR vessel materials (A212-B, A350-LF3, A105-II) were substantially greater than anticipated on the basis of MTR data. Further evaluation of the HFIR data suggested that a fluence-rate effect was responsible for the apparent discrepancy, and shortly thereafter it became apparent that this rate effect was applicable to the evaluation of LWR vessel supports. As a result, the Nuclear Regulatory Commission (NRC) requested that the Oak Ridge National Laboratory (ORNL) evaluate the impact of the apparent embrittlement rate effect on the integrity of light-water-reactor (LWR) vessel supports. The purpose of the study was to provide an indication of whether the integrity of reactor vessel supports is likely to be challenged by radiation-induced embrittlement. The scope of the evaluation included correlation of the HFIR data for application to the evaluation of LWR vessel supports; a survey and cursory evaluation of all US LWR vessel support designs, selection of two plants for specific-plant evaluation, and a specific-plant evaluation of both plants to determine critical flaw sizes for their vessel supports. 19 refs., 8 figs., 2 tabs

  8. Prestressed cast iron pressure vessels as burst-proof pressure vessels for innovative nuclear applications

    International Nuclear Information System (INIS)

    Froehling, W.; Boettcher, A.; Bounin, D.; Steinwarz, W.; Geiss, M.; Trauth, M.

    2000-01-01

    The amendment to the German Atomic Energy Act from July 28, 1994 requires that events 'whose occurrence is practically excluded by the measures against damages', i.e. events of the category residual risk, must not necessitate far reaching protective measures outside the plant. For a conventional reactor pressure vessel, the residual risk consists in the very small probability of a catastrophic failure (formation of a large fracture opening, bursting of the vessel). With a prestressed cast iron vessel (PCIV), the formation of a large fracture opening or bursting of the vessel, respectively, is impossible due to its design properties. Against this background the possibility of the use of this type of pressure vessel for lightwater reactors has been studied in the frame of a 'Working Group for Innovative Nuclear Technology', founded by different research institutes and industrial companies. Furthermore, it has been studied whether the use of the PCIV support the realization of a corecatcher system. The results are presented in this report. Already many years earlier, Siempelkamp has performed industrial development and Forschungszentrum Juelich related experimental and theoretical safety research for the PCIV as an innovative, bust-proof pressure vessel concept. This development of the PCIV as well as its safety properties are also presented in a conclusive manner. (orig.) [de

  9. 46 CFR 4.03-40 - Public vessels.

    Science.gov (United States)

    2010-10-01

    ... INVESTIGATIONS Definitions § 4.03-40 Public vessels. Public vessel means a vessel that— (a) Is owned, or demise... Department (except a vessel operated by the Coast Guard or Saint Lawrence Seaway Development Corporation...

  10. Digoxin affects potassium homeostasis during exercise in patients with heart failure.

    Science.gov (United States)

    Schmidt, T A; Bundgaard, H; Olesen, H L; Secher, N H; Kjeldsen, K

    1995-04-01

    The aim was to evaluate whether digitalisation of heart failure patients affects extrarenal potassium handling during and following exercise, and to assess digoxin receptor occupancy in human skeletal muscle in vivo. In a paired study of before versus after digitalisation, 10 patients with congestive heart failure underwent identical exercise sessions consisting of three bouts of increasing work rates, 41-93 W, on a cycle ergometer. The final bouts were followed by exercise to exhaustion. The femoral vessels and brachial artery were catheterised. Arterial blood pressure, heart rate, leg blood flow, cardiac output, plasma potassium, haemoglobin, pH, and skeletal muscle receptor occupancy with digoxin in biopsies were determined. Occupancy of skeletal muscle Na/K-ATPase with digoxin was 9% (P digitalisation femoral venous plasma potassium increased by 0.2-0.3 mmol.litre-1 (P digitalisation the femoral venoarterial difference in plasma potassium increased by 50-100% (P digitalisation on plasma potassium were not the outcome of changes in haemodynamics, because cardiac output and leg blood flow increased by up to 13% and 19% (P < 0.05), nor was it the outcome of changes in haemoconcentration or pH. Extrarenal potassium handling is altered as a result of digoxin treatment. This is likely to reflect a reduced capacity of skeletal muscle Na/K-ATPase for active potassium uptake because of inhibition by digoxin, adding to the reduction of skeletal muscle Na/K-ATPase concentration induced by heart failure per se. In heart failure patients, improved haemodynamics induced by digoxin may, however, increase the capacity for physical conditioning. Thus the impairment of extrarenal potassium homeostasis by heart failure and digoxin treatment may be counterbalanced by training.

  11. Modeling the Role of the Glymphatic Pathway and Cerebral Blood Vessel Properties in Alzheimer's Disease Pathogenesis.

    Science.gov (United States)

    Kyrtsos, Christina Rose; Baras, John S

    2015-01-01

    Alzheimer's disease (AD) is the most common cause of dementia in the elderly, affecting over 10% population over the age of 65 years. Clinically, AD is described by the symptom set of short term memory loss and cognitive decline, changes in mentation and behavior, and eventually long-term memory deficit as the disease progresses. On imaging studies, significant atrophy with subsequent increase in ventricular volume have been observed. Pathology on post-mortem brain specimens demonstrates the classic findings of increased beta amyloid (Aβ) deposition and the presence of neurofibrillary tangles (NFTs) within affected neurons. Neuroinflammation, dysregulation of blood-brain barrier transport and clearance, deposition of Aβ in cerebral blood vessels, vascular risk factors such as atherosclerosis and diabetes, and the presence of the apolipoprotein E4 allele have all been identified as playing possible roles in AD pathogenesis. Recent research has demonstrated the importance of the glymphatic system in the clearance of Aβ from the brain via the perivascular space surrounding cerebral blood vessels. Given the variety of hypotheses that have been proposed for AD pathogenesis, an interconnected, multilayer model offers a unique opportunity to combine these ideas into a single unifying model. Results of this model demonstrate the importance of vessel stiffness and heart rate in maintaining adequate clearance of Aβ from the brain.

  12. Embryonic Heart Morphogenesis from Confocal Microscopy Imaging and Automatic Segmentation

    Directory of Open Access Journals (Sweden)

    Hongda Mao

    2013-01-01

    Full Text Available Embryonic heart morphogenesis (EHM is a complex and dynamic process where the heart transforms from a single tube into a four-chambered pump. This process is of great biological and clinical interest but is still poorly understood for two main reasons. On the one hand, the existing imaging modalities for investigating EHM suffered from either limited penetration depth or limited spatial resolution. On the other hand, current works typically adopted manual segmentation, which was tedious, subjective, and time consuming considering the complexity of developing heart geometry and the large size of images. In this paper, we propose to utilize confocal microscopy imaging with tissue optical immersion clearing technique to image the heart at different stages of development for EHM study. The imaging method is able to produce high spatial resolution images and achieve large penetration depth at the same time. Furthermore, we propose a novel convex active contour model for automatic image segmentation. The model has the ability to deal with intensity fall-off in depth which is characterized by confocal microscopy images. We acquired the images of embryonic quail hearts from day 6 to day 14 of incubation for EHM study. The experimental results were promising and provided us with an insight view of early heart growth pattern and also paved the road for data-driven heart growth modeling.

  13. Image quality of CT angiography in young children with congenital heart disease: a comparison between the sinogram-affirmed iterative reconstruction (SAFIRE) and advanced modelled iterative reconstruction (ADMIRE) algorithms.

    Science.gov (United States)

    Nam, S B; Jeong, D W; Choo, K S; Nam, K J; Hwang, J-Y; Lee, J W; Kim, J Y; Lim, S J

    2017-12-01

    To compare the image quality of computed tomography angiography (CTA) reconstructed by sinogram-affirmed iterative reconstruction (SAFIRE) with that of advanced modelled iterative reconstruction (ADMIRE) in children with congenital heart disease (CHD). Thirty-one children (8.23±13.92 months) with CHD who underwent CTA were enrolled. Images were reconstructed using SAFIRE (strength 5) and ADMIRE (strength 5). Objective image qualities (attenuation, noise) were measured in the great vessels and heart chambers. Two radiologists independently calculated the contrast-to-noise ratio (CNR) by measuring the intensity and noise of the myocardial walls. Subjective noise, diagnostic confidence, and sharpness at the level prior to the first branch of the main pulmonary artery were also graded by the two radiologists independently. The objective image noise of ADMIRE was significantly lower than that of SAFIRE in the right atrium, right ventricle, and myocardial wall (p0.05). The mean CNR values were 21.56±10.80 for ADMIRE and 18.21±6.98 for SAFIRE, which were significantly different (p0.05). CTA using ADMIRE was superior to SAFIRE when comparing the objective and subjective image quality in children with CHD. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  14. Prosopomorphic vessels from Moesia Superior

    Directory of Open Access Journals (Sweden)

    Nikolić Snežana

    2008-01-01

    Full Text Available The prosopomorphic vessels from Moesia Superior had the form of beakers varying in outline but similar in size. They were wheel-thrown, mould-made or manufactured by using a combination of wheel-throwing and mould-made appliqués. Given that face vessels are considerably scarcer than other kinds of pottery, more than fifty finds from Moesia Superior make an enviable collection. In this and other provinces face vessels have been recovered from military camps, civilian settlements and necropolises, which suggests that they served more than one purpose. It is generally accepted that the faces-masks gave a protective role to the vessels, be it to protect the deceased or the family, their house and possessions. More than forty of all known finds from Moesia Superior come from Viminacium, a half of that number from necropolises. Although tangible evidence is lacking, there must have been several local workshops producing face vessels. The number and technological characteristics of the discovered vessels suggest that one of the workshops is likely to have been at Viminacium, an important pottery-making centre in the second and third centuries.

  15. Imaging findings in the right aortic arch with mirror image branching of arch vessels: An unusual cause of dysphagia

    Directory of Open Access Journals (Sweden)

    Guneet Singh

    2015-01-01

    Full Text Available We report a case of a 72-year-old female with a right aortic arch with mirror-image branching of arch vessels presenting with dysphagia, and characteristic images on barium esophagogram, contrast-enhanced computed tomography scan, and magnetic resonance aortography. Right-sided thoracic aortic arch with mirror-image branching of the brachiocephalic vessels causing dysphagia without associated congenital cardiac anomalies is extremely uncommon. Right-sided aortic arch is a rare congenital abnormality with incidence of 0.05-0.1% in the normal population. Anomalies of great vessels are usually incidental findings, because they are asymptomatic. Right aortic arch infrequently presents with a vascular ring that can cause complete or partial obstruction of the trachea and/or esophagus. The understanding of this arch anomaly is based on Edward′s hypothesis about the double arch system during embryonic developmental.

  16. Nuclear reactor pressure vessel flaw distribution development

    International Nuclear Information System (INIS)

    Kennedy, E.L.; Foulds, J.R.; Basin, S.L.

    1991-12-01

    Previous attempts to develop flaw distributions for probabilistic fracture mechanics analyses of pressurized water reactor (PWR) vessels have aimed at the estimation of a ''generic'' distribution applicable to all PWR vessels. In contrast, this report describes (1) a new flaw distribution development analytic methodology that can be applied to the analysis of vessel-specific inservice inspection (ISI) data, and (2) results of the application of the methodology to the analysis of flaw data for each vessel case (ISI data on three PWR vessels and laboratory inspection data on sections of the Midland reactor vessel). Results of this study show significant variation among the flaw distributions derived from the various data sets analyzed, strongly suggesting than a vessel-specific flaw distribution (for vessel integrity prediction under pressurized thermal shock) is preferred over a ''generic'' distribution. In addition, quantitative inspection system flaw sizing accuracy requirements have been identified for developing a flaw distribution from vessel ISI data. The new flaw data analysis methodology also permits quantifying the reliability of the flaw distribution estimate. Included in the report are identified needs for further development of several aspects of ISI data acquisition and vessel integrity prediction practice

  17. Cyanotic congenital heart disease

    International Nuclear Information System (INIS)

    Yeon, Kyung Mo; Yoo, Shi Joon; Han, Man Chung; Hong, Chang Yee; Lee, Yung Kyoon

    1979-01-01

    Authors analyzed 265 cases of cyanotic congenital heart disease in which cardiac catheterization and angiocardiography were done at the Department of Radiology, Seoul National University Hospital between April 1973 and August 1979. The results are as follows; 1. Among 265 cases, 178 patients were male and 87 patients were female. 240 patients were below the age of 20 and none was over 35 year. 2. The incidence of individual lesions are as follows: tetralogy of Fallot-176; double outlet right ventricle-20; pentalogy-12; trilogy-11; corrected transposition of great arteries-10; complete transposition of great arteries-8; pulmonary atresia-7; single ventricle-6; Ebstein's anomaly-5; total anomalous pulmonary venous return-4; tricuspid atresia-3; double outlet left ventricle-1; truncus arteriosus-1; hypoplastic left ventricle-1. 3. Fallot's teralogy, pentalogy and trilogy were characteristic in their simple chest and angiocardiographic manifestations, but in a few cases of tetralogy and pentalogy it was difficult to differentiate them from double outlet right ventricle or pulmonary atresia. 4. In double outlet right ventricle and transposition of great arteries which are the pathologic spectrum resulting from abnormal conal growth, differential points were ventricular and great arterial loop patterns and their connections but it was very difficult to differentiate them from each other by single injection into one ventricle alone. 5. Ebstein's anomaly and total anomalous pulmonary venous return were so characteristic in angiocardiography was done ventriculography alone. 6. In 7 cases with double outlet right ventricle and transposition of great arteries, selective biventriculography was done and more accurate diagnosis could be made, which was quite difficult with one ventriculography alone. In 31 cases, cineangiocardiography was done and it gave more accurate information about the type and degree of pulmonary stenosis and overriding of aorta, the origin of great

  18. Targeting Therapy Resistant Tumor Vessels

    Science.gov (United States)

    2008-08-01

    Morris LS. Hysterectomy vs. resectoscopic endometrial ablation for the control of abnormal uterine bleeding . A cost-comparative study. J Reprod Med 1994;39...after the antibody treatment contain a pericyte coat, vessel architecture is normal, the diameter of the vessels is smaller (dilated, abnormal vessels...involvement of proteases from inflammatory mast cells and functionally abnormal (Carmeliet and Jain, 2000; Pasqualini (Coussens et al., 1999) and other bone

  19. Pressurized wet digestion in open vessels (T11)

    International Nuclear Information System (INIS)

    Kettisch, P.; Maichin, P.; Zischka, M.; Knapp, G.

    2002-01-01

    Full text: Pressurized wet digestion in closed vessels, microwave assisted or with conventional conductive heating, is the most important sample preparation technique for digestion or leaching procedures in element analysis. In comparison to open vessel digestion closed vessel digestion methods have many advantages, but there is one disadvantage - complex and expensive vessel designs. A new technique - pressurized wet digestion in open vessels - combine the advantages of closed vessel sample digestion with the application of simple and cheap open vessels made of quartz or PFA. The vessels are placed in a high pressure Asher HPA, which is adapted with a Teflon liner and filled partly with water. The analytical results with 30 ml quartz vessels, 22 ml PFA vessels and 1.5 ml PIA auto sampler cups will be shown. In principle every dimensions of vessels can be used. The vessels are loaded with sample material (max. 1.5 g with quartz vessels, max. 0.5 g with PFA vessels and 50 mg with auto sampler cups) and digestion reagent. Afterwards the vessels are simply covered with PTFE stoppers and not sealed. The vessels are transferred into a special adapted HPA and digested at temperatures up to 270 o C. The digestion time is 90 min. and cooling down to room temperature 30 min. The analytical results of CRM's are within the certified values and no cross contamination and losses of volatile elements could be observed. (author)

  20. Flaw distribution development from vessel ISI data

    International Nuclear Information System (INIS)

    Foulds, J.R.; Kennedy, E.L.; Basin, S.L.; Rosinski, S.T.

    1991-01-01

    Previous attempts to develop flaw distributions for use in the structural integrity evaluation of pressurized water reactor (PWR) vessels have aimed at the estimation of a ''generic'' distribution applicable to all vessels. In contrast, this paper describes the analysis of vessel-specific in-service inspection (ISI) data for the development of a flaw distribution reliably representative of the condition of the particular vessel inspected. The application of the methodology may be extended to other vessels, but has been primarily developed for PWR reactor vessels. For this study, the flaw data analyzed included data obtained from three recently performed PWR vessel ISIs and from laboratory inspection of selected weldment sections of the Midland reactor vessel. The variability in both the character of the reviewed data (size range of flaws, number of flaws) and the UT (ultrasonic test) inspection system performance identified a need for analyzing the inspection results on a vessel-, or data set-specific basis. For this purpose, traditional histogram-based methods were inadequate, and a new methodology that can accept a very small number of flaws (typical of vessel-specific ISI results) and that includes consideration of inspection system flaw detection reliability, flaw sizing accuracy and flaw detection threshold, was developed. Results of the application of the methodology to each of the four PWR reactor vessel cases studied are presented and discussed

  1. Seals for sealing a pressure vessel such as a nuclear reactor vessel or the like

    International Nuclear Information System (INIS)

    Bruns, H.J.; Huelsermann, K.H.

    1975-01-01

    A description is given of seals for sealing a pressure vessel such as a nuclear reactor vessel, steam boiler vessel, or any other vessel which is desirably sealed against pressure of the type including a housing and a housing closure that present opposed vertical sealing surfaces which define the sides of a channel. The seals of the present invention comprise at least one sealing member disposed in the channel, having at least one stop face, a base portion and two shank portions extending from the base portion to form a groove-like recess. The shank portions are provided with sealing surfaces arranged to mate with the opposed vertical pressure vessel sealing surfaces. A shank-spreading wedge element also disposed in the channel has at least one stop face and is engaged in the groove-like recess with the sealing member and wedge element stop face adjacent to each other

  2. Elliptical local vessel density: a fast and robust quality metric for retinal images

    OpenAIRE

    Giancardo, L.; Abramoff, M.D.; Chaum, E.; Karnowski, T.P.; Meriaudeau, F.; Tobin, K.W.

    2008-01-01

    A great effort of the research community is geared towards the creation of an automatic screening system able to promptly detect diabetic retinopathy with the use of fundus cameras. In addition, there are some documented approaches for automatically judging the image quality. We propose a new set of features independent of field of view or resolution to describe the morphology of the patient's vessels. Our initial results suggest that these features can be used to estimate the image quality i...

  3. Proposal of Ex-Vessel dosimetry for pressure vessel Atucha II

    International Nuclear Information System (INIS)

    Chiaraviglio, N.; Bazzana, S.

    2013-01-01

    Nuclear reactor dosimetry has the purpose of guarantee that changes in material mechanical properties of critical materials do not compromise the reactor safety. In PWR in which the top of the reactor vessel is open once a year, is possible to use Charpy specimens to measure the change in mechanical properties. Atucha II nuclear power plant is a reactor with on-line refueling so there is no access to the inside of the pressure vessel. Because of this, ex-vessel dosimetry must be performed and mechanical properties changes must be inferred from radiation damage estimations. This damage can be calculated using displacement per atom cross sections and a transport code such as MCNP. To increase results reliability it is proposed to make a neutron spectrum unfolding using activation dosimeters irradiated during one operation cycle of the power plant. In this work we present a dosimetry proposal for such end, made in base of unfolding procedures and experimental background. (author) [es

  4. Clinical application of the amplatzer vascular plug in the embolization of vascular malformations associated with congenital heart diseasee

    International Nuclear Information System (INIS)

    Pan Xin; Wang Cheng; Lu Jing; Wu Weihua; Fang Weiyi

    2009-01-01

    Objective: To evaluate the clinical efficacy of percutaneous transcatheter embolization by using Amplatzer vascular plug (AVP) for the treatment of vascular malformations associated with congenital heart diseases. Methods: During the period of June 2006-June 2008, 12 patients with congenital heart disease accompanied by vascular malformations received transcatheter occlusion of the anomalous vessels with AVP. The vascular malformations included solitary or multiple saccular pulmonary arteriovenous malformation (n = 7), coronary artery fistula (n = 2) and major aortopulmonary collaterals concomitant with severe Fallot' s tetralogy (n = 3). All patients were screened with transthoracic echocardiography (TTE) and thoracic CT angiography (CTA), and all the diagnoses were confirmed by routine cardioangiography. Results: Transcatheter occlusion of vascular malformations with AVP was successfully accomplished in all 12 patients. An angiographic check immediately after the procedure showed that complete occlusion was obtained in all patients and no embolism,migration or residual shunt were seen. Sixteen anomalous vessels were occluded. The mean internal diameter of these vessels was (5.2 ± 1.9) mm,while the mean diameter of AVP used was (9.2 ± 2.4) mm. After the operation (mean 3 months), the follow-up echocardiography and/or thoracic CT angiography showed that in all patients the occlusion remained in satisfactory condition and no residual shunt was found. Conclusions: Percutaneous transcatheter closure of congenital vascular malformations with AVP is technically feasible and clinically effective, this treatment can markedly improve patient's living quality and it is well worth extending its clinical application. (authors)

  5. High Performance Marine Vessels

    CERN Document Server

    Yun, Liang

    2012-01-01

    High Performance Marine Vessels (HPMVs) range from the Fast Ferries to the latest high speed Navy Craft, including competition power boats and hydroplanes, hydrofoils, hovercraft, catamarans and other multi-hull craft. High Performance Marine Vessels covers the main concepts of HPMVs and discusses historical background, design features, services that have been successful and not so successful, and some sample data of the range of HPMVs to date. Included is a comparison of all HPMVs craft and the differences between them and descriptions of performance (hydrodynamics and aerodynamics). Readers will find a comprehensive overview of the design, development and building of HPMVs. In summary, this book: Focuses on technology at the aero-marine interface Covers the full range of high performance marine vessel concepts Explains the historical development of various HPMVs Discusses ferries, racing and pleasure craft, as well as utility and military missions High Performance Marine Vessels is an ideal book for student...

  6. Reactor-vessel-sectioning demonstration

    International Nuclear Information System (INIS)

    Lundgren, R.A.

    1981-07-01

    A successful technical demonstration of simulated reactor vessel sectioning was completed using the combined techniques of air arc gouging and flame cutting. A 4-ft x 3-ft x 9-in. thick sample was fabricated of A36 carbon steel to simulate a reactor vessel wall. A 1/4-in layer of stainless steel (SS) was tungsten inert gas (TIG)-welded to the carbon steel. Several techniques were considered to section the simulated reactor vessel: an air arc gouger was chosen to penetrate the stainless steel, and flame cutting was selected to sever the carbon steel. After the simulated vessel was successfully cut from the SS side, another cut was made, starting from the carbon steel side. This cut was also successful. Cutting from the carbon steel side has the advantages of cost reduction since the air arc gouging step is eliminated and contamination controlled because the molten metal is blown inward

  7. The vessel fluence; Fluence cuve

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    This book presents the proceedings of the technical meeting on the reactors vessels fluence. They are grouped in eight sessions: the industrial context and the stakes of the vessels control; the organization and the methodology for the fluence computation; the concerned physical properties; the reference computation methods; the fluence monitoring in an industrial context; vessels monitoring under irradiation; others methods in the world; the research and development programs. (A.L.B.)

  8. Thyroid Storm with Heart Failure Treated with a Short-acting Beta-adrenoreceptor Blocker, Landiolol Hydrochloride.

    Science.gov (United States)

    Yamashita, Yugo; Iguchi, Moritake; Nakatani, Rieko; Usui, Takeshi; Takagi, Daisuke; Hamatani, Yasuhiro; Unoki, Takashi; Ishii, Mitsuru; Ogawa, Hisashi; Masunaga, Nobutoyo; Abe, Mitsuru; Akao, Masaharu

    2015-01-01

    Beta-adrenoreceptor blockers are essential in controlling the peripheral actions of thyroid hormones and a rapid heart rate in patients with thyroid storm, although they should be used with great caution when there is the potential for heart failure. A 67-year-old woman was diagnosed as having thyroid storm in addition to marked tachycardia with atrial fibrillation and heart failure associated with a reduced left ventricular function. The administration of an oral beta blocker, bisoprolol fumarate, induced hypotension and was not tolerable for the patient, whereas landiolol hydrochloride, a short-acting intravenous beta-adrenoreceptor blocker with high cardioselectivity and a short elimination half-life, was useful for controlling the patient's tachycardia and heart failure without causing hemodynamic deterioration.

  9. Expanded Fermilab pressure vessel directory program

    Energy Technology Data Exchange (ETDEWEB)

    Tanner, A.

    1983-01-01

    Several procedures have been written to manage the information pertaining to the vacuum tanks and pressure vessels for which the laboratory is responsible. These procedures have been named TANK1 for the vessels belonging to the Accelerator Division, TANK2 and TANK3 for the vessels belonging to the Research Division and to Technical Support respectively, and TANK4 for the vessels belonging to the Business Division. The operating procedures are otherwise identical in every respect.

  10. Expanded Fermilab pressure vessel directory program

    International Nuclear Information System (INIS)

    Tanner, A.

    1983-01-01

    Several procedures have been written to manage the information pertaining to the vacuum tanks and pressure vessels for which the laboratory is responsible. These procedures have been named TANK1 for the vessels belonging to the Accelerator Division, TANK2 and TANK3 for the vessels belonging to the Research Division and to Technical Support respectively, and TANK4 for the vessels belonging to the Business Division. The operating procedures are otherwise identical in every respect

  11. Effect of the in- and ex-vessel dual cooling on the retention of an internally heated melt pool in a hemispherical vessel

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, K.I.; Kim, B.S.; Kim, D.H. [Korea Atomic Energy Research Inst., Thermal Hydraulic Safety Research, Taejon (Korea, Republic of)

    2001-07-01

    A concept of in-vessel melt retention (IVMR) by in-vessel reflooding and/or reactor cavity flooding has been considered as one of severe accident management strategies and intensive researches to be performed worldwide. This paper provides some results of analytical investigations on the effect of both in- / ex-vessel cooling on the retention of an internally heated molten pool confined in a hemispherical vessel and the related thermal behavior of the vessel wall. For the present analysis, a scale-down reactor vessel for the KSNP reactor design of 1000 MWe (a large dry PWR) is utilized for a reactor vessel. Aluminum oxide melt simulant is also utilized for a real corium pool. An internal power density in the molten pool is determined by a simple scaling analysis that equates the heat flux on the the scale-down vessel wall to that estimated from KSNP. Well-known temperature-dependent boiling heat transfer curves are applied to the in- and ex-vessel cooling boundaries and radiative heat transfer has been only considered in the case of dry in-vessel. MELTPOOL, which is a computational fluid dynamics (CFD) code developed at KAERI, is applied to obtain the time-varying heat flux distribution from a molten pool and the vessel wall temperature distributions with angular positions along the vessel wall. In order to gain further insights on the effectiveness of in- and ex-vessel dual cooling on the in-vessel corium retention, four different boundary conditions has been considered: no water inside the vessel without ex-vessel cooling, water inside the vessel without ex-vessel cooling, no water inside the vessel with ex-vessel cooling, and water inside the vessel with ex-vessel cooling. (authors)

  12. Effect of the in- and ex-vessel dual cooling on the retention of an internally heated melt pool in a hemispherical vessel

    International Nuclear Information System (INIS)

    Ahn, K.I.; Kim, B.S.; Kim, D.H.

    2001-01-01

    A concept of in-vessel melt retention (IVMR) by in-vessel reflooding and/or reactor cavity flooding has been considered as one of severe accident management strategies and intensive researches to be performed worldwide. This paper provides some results of analytical investigations on the effect of both in- / ex-vessel cooling on the retention of an internally heated molten pool confined in a hemispherical vessel and the related thermal behavior of the vessel wall. For the present analysis, a scale-down reactor vessel for the KSNP reactor design of 1000 MWe (a large dry PWR) is utilized for a reactor vessel. Aluminum oxide melt simulant is also utilized for a real corium pool. An internal power density in the molten pool is determined by a simple scaling analysis that equates the heat flux on the the scale-down vessel wall to that estimated from KSNP. Well-known temperature-dependent boiling heat transfer curves are applied to the in- and ex-vessel cooling boundaries and radiative heat transfer has been only considered in the case of dry in-vessel. MELTPOOL, which is a computational fluid dynamics (CFD) code developed at KAERI, is applied to obtain the time-varying heat flux distribution from a molten pool and the vessel wall temperature distributions with angular positions along the vessel wall. In order to gain further insights on the effectiveness of in- and ex-vessel dual cooling on the in-vessel corium retention, four different boundary conditions has been considered: no water inside the vessel without ex-vessel cooling, water inside the vessel without ex-vessel cooling, no water inside the vessel with ex-vessel cooling, and water inside the vessel with ex-vessel cooling. (authors)

  13. Lymphangiogenesis is increased in heart valve endocarditis.

    Science.gov (United States)

    Niinimäki, Eetu; Mennander, Ari A; Paavonen, Timo; Kholová, Ivana

    2016-09-15

    Inflammation-associated lymphangiogenesis (IAL) has been identified as part of several acute and chronic inflammation. Sparse data exist on lymphatics during endocarditis. Fifty-two patients with surgically resected valves were included. Endocarditis was present in 18 aortic and 10 mitral valves. Controls consisted of 15 degenerative aortic and 9 degenerative mitral valves. There were 22 males with endocarditis and 17 males in controls. The mean age was 58 (SD 15) years with endocarditis vs. 62 (SD 13) years for controls. Lymphatics were detected by podoplanin antibody immunohistochemistry and morphometrical analysis was performed. The lymphatic density in endocarditis was 833 (SD 529) vessels/mm(2) (range 0-1707) as compared with 39 (SD 60) vessels/mm(2) (range 0-250) in controls (p=0.000). In endocarditis, the mean lymphatic size was 153 (SD 372) μm(2) ranging from 1 to 2034μm(2), whereas it was 30 (SD 29) μm(2), with maximum 90μm(2) and minimum 2μm(2) in controls (p=0.000). IAL is increased in valves with endocarditis as compared with controls. Lymphatics in heart valves may provide a novel means for treatment strategies against endocarditis. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  14. Role of nuclear medicine in ischemic heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Hayashida, Kohei; Nishimura, Tsunehiko; Uehara, Toshiisa; Naito, Hiroaki; Omine, Hiromi; Kozuka, Takahiro [National Cardiovascular Center, Suita, Osaka (Japan)

    1982-08-01

    With the progress in gamma camera and computer system, nuclear medicine has been applied for diagnostic tool in ischemic heart disease. There are two devices for cardiac images; (1) Radionuclide angiocardiography (RNA) by in vivo sup(99m)Tc-RBC labeling (2) Myocardial imaging by /sup 201/Tlcl. RNA can evaluate the kinesis of wall motion of left ventricle with gated pool scan and also detect reserve of cardiac function with exercise study. Myocardial imaging at rest can identify myocardial necrosis and the imaging in exercise can detect myocardial ischemia. The elaborateness and reproducibility of cardiac image in nuclear medicine will play the great role to evaluate clinical stage of ischemic heart disease by not only imaging but also functional diagnosis.

  15. Preattentive processing of heart cues and the perception of heart symptoms in congenital heart disease.

    Science.gov (United States)

    Karsdorp, Petra A; Kindt, Merel; Everaerd, Walter; Mulder, Barbara J M

    2007-08-01

    The present study was aimed at clarifying whether preattentive processing of heart cues results in biased perception of heart sensations in patients with congenital heart disease (ConHD) who are also highly trait anxious. Twenty-six patients with ConHD and 22 healthy participants categorized heart-related (heart rate) or neutral sensations (constant vibration) as either heart or neutral. Both sensations were evoked using a bass speaker that was attached on the chest of the participant. Before each physical sensation, a subliminal heart-related or neutral prime was presented. Biased perception of heart-sensations would become evident by a delayed categorization of the heart-related sensations. In line with the prediction, a combination of high trait anxiety and ConHD resulted in slower responses after a heart-related sensation that was preceded by a subliminal heart cue. Preattentive processing of harmless heart cues may easily elicit overperception of heart symptoms in highly trait anxious patients with ConHD.

  16. Lipid metabolism in the heart. Contribution of BMIPP to the diseased heart

    Energy Technology Data Exchange (ETDEWEB)

    Nohara, Ryuji [Tazuke Kofukai Medical Research Inst., Osaka (Japan). Kitano Hospital

    2001-10-01

    Lipid contributes greatly in cardiac metabolism to produce high energy ATPs, and is suggested to be related to the progression and deterioration of heart disease. It is fortunate that the I-123-betamethyliodophenylpentadecanoic acid (BMIPP) imaging technique is now available in determining heart condition, but we must be cautious about the interpretation of images obtained with new tracer. From the uptake of BMIPP into the cell to breakdown and catabolism of it, there exist so many critical enzymatical pathways relating to the modification of BMIPP imaging. In clinical evaluation, the image will be translated as the integral effects of these pathways. In order words, we must be aware of these critical pathways regulating lipid metabolism and modifying factors in order to correctly understand BMIPP imaging. Lipid transport is affected by the albumin/FFA ratio in the blood, and extraction with membrane transporter proteins. Fatty acid binding protein (FABP) in the cytosole will play an important role in regulating lipid flux and following metabolism. Lipid will be utilized either for oxidation, triglyceride or phospholipid formation. For oxidation, carnitine palmitoil transferase is the key enzyme for the entrance of lipid into mitochondria, and oxidative enzymes such as acyl CoA dehydrogenase (MCAD, LCAD, HAD) will determine lipid use for the TCA cycle. ATPs produced in the mitochondria again limit the TG store. It is well known that BMIPP imaging completely changes in the ischemic condition, and is also shown that lipid metabolical regulation completely differs from normal in the very early phase of cardiac hypertrophy. In the process of deteriorating heart failure, metabolical switching of lipid with glucose will take place. In such a different heart disease conditions, it is clear that lipid metabolical regulation, including many lipid enzymes, works differently from in the healthy condition. These lipid enzymes are regulated by nuclear factor peroxisome

  17. High-resolution motion compensated MRA in patients with congenital heart disease using extracellular contrast agent at 3 Tesla

    Directory of Open Access Journals (Sweden)

    Dabir Darius

    2012-10-01

    Full Text Available Abstract Background Using first-pass MRA (FP-MRA spatial resolution is limited by breath-hold duration. In addition, image quality may be hampered by respiratory and cardiac motion artefacts. In order to overcome these limitations an ECG- and navigator-gated high-resolution-MRA sequence (HR-MRA with slow infusion of extracellular contrast agent was implemented at 3 Tesla for the assessment of congenital heart disease and compared to standard first-pass-MRA (FP-MRA. Methods 34 patients (median age: 13 years with congenital heart disease (CHD were prospectively examined on a 3 Tesla system. The CMR-protocol comprised functional imaging, FP- and HR-MRA, and viability imaging. After the acquisition of the FP-MRA sequence using a single dose of extracellular contrast agent the motion compensated HR-MRA sequence with isotropic resolution was acquired while injecting the second single dose, utilizing the timeframe before viability imaging. Qualitative scores for image quality (two independent reviewers as well as quantitative measurements of vessel sharpness and relative contrast were compared using the Wilcoxon signed-rank test. Quantitative measurements of vessel diameters were compared using the Bland-Altman test. Results The mean image quality score revealed significantly better image quality of the HR-MRA sequence compared to the FP-MRA sequence in all vessels of interest (ascending aorta (AA, left pulmonary artery (LPA, left superior pulmonary vein (LSPV, coronary sinus (CS, and coronary ostia (CO; all p  Conclusions An ECG- and navigator-gated HR-MRA-protocol with infusion of extracellular contrast agent at 3 Tesla is feasible. HR-MRA delivers significantly better image quality and vessel sharpness compared to FP-MRA. It may be integrated into a standard CMR-protocol for patients with CHD without the need for additional contrast agent injection and without any additional examination time.

  18. [Endothelial dysfunction as a marker of vascular aging syndrome on the background of hypertension, coronary heart disease, gout and obesity].

    Science.gov (United States)

    Vatseba, M O

    2013-09-01

    Under observation were 40 hypertensive patients with coronary heart disease, gout and obesity I and II degree. Patients with hypertension in combination with coronary heart disease, gout and obesity, syndrome of early vascular aging is shown by increased stiffness of arteries, increased peak systolic flow velocity, pulse blood presure, the thickness of the intima-media complex, higher level endotelinemia and reduced endothelial vasodilation. Obtained evidence that losartan in complex combination with basic therapy and metamaks in complex combination with basic therapy positively affect the elastic properties of blood vessels and slow the progression of early vascular aging syndrome.

  19. Tempest in a vessel

    International Nuclear Information System (INIS)

    Barre, Bertrand

    2015-01-01

    As the ASN made some statements about anomalies of carbon content in the EPR vessel bottom and top, the author recalls and comments some technical issues to better understand the information published on this topic. He notably addresses the role of the vessel, briefly indicates its operating conditions, shape and structure, and mechanical components for the top, its material and mechanical properties, and test samples used to assess mechanical properties. He also comments the phenomenon of radio-induced embrittlement, the vessel manufacturing process, and evokes the applicable regulations. He quotes and comments statements made by the ASN and Areva which evoke further assessments of the concerned components

  20. Khat Use: History and Heart Failure

    Directory of Open Access Journals (Sweden)

    Ayman El-Menyar

    2015-03-01

    Full Text Available Recent reports suggest that 20 million people worldwide are regularly using khat as a stimulant, even though the habit of chewing khat is known to cause serious health issues. Historical evidence suggests khat use has existed since the 13th century in Ethiopia and the southwestern Arabian regions even before the cultivation and use of coffee. In the past three decades, its availability and use spread all over the world including the United States and Europe. Most of the consumers in the Western world are immigrant groups from Eastern Africa or the Middle East. The global transport and availability of khat has been enhanced by the development of synthetic forms of its active component. The World Health Organization considers khat a drug of abuse since it causes a range of health problems. However, it remains lawful in some countries. Khat use has long been a part of Yemeni culture and is used in virtually every social occasion. The main component of khat is cathinone, which is structurally and functionally similar to amphetamine and cocaine. Several studies have demonstrated that khat chewing has unfavorable cardiovascular effects. The effect on the myocardium could be explained by its effect on the heart rate, blood pressure, its vasomotor effect on the coronary vessels, and its amphetamine–like effects. However, its direct effect on the myocardium needs further elaboration. To date, there are few articles that contribute death among khat chewers to khat-induced heart failure. Further studies are needed to address the risk factors in khat chewers that may explain khat-induced cardiotoxicity, cardiomyopathy, and heart failure.

  1. Automatic Vessel Segmentation on Retinal Images

    Institute of Scientific and Technical Information of China (English)

    Chun-Yuan Yu; Chia-Jen Chang; Yen-Ju Yao; Shyr-Shen Yu

    2014-01-01

    Several features of retinal vessels can be used to monitor the progression of diseases. Changes in vascular structures, for example, vessel caliber, branching angle, and tortuosity, are portents of many diseases such as diabetic retinopathy and arterial hyper-tension. This paper proposes an automatic retinal vessel segmentation method based on morphological closing and multi-scale line detection. First, an illumination correction is performed on the green band retinal image. Next, the morphological closing and subtraction processing are applied to obtain the crude retinal vessel image. Then, the multi-scale line detection is used to fine the vessel image. Finally, the binary vasculature is extracted by the Otsu algorithm. In this paper, for improving the drawbacks of multi-scale line detection, only the line detectors at 4 scales are used. The experimental results show that the accuracy is 0.939 for DRIVE (digital retinal images for vessel extraction) retinal database, which is much better than other methods.

  2. Heart transplantation in adults with congenital heart disease.

    Science.gov (United States)

    Houyel, Lucile; To-Dumortier, Ngoc-Tram; Lepers, Yannick; Petit, Jérôme; Roussin, Régine; Ly, Mohamed; Lebret, Emmanuel; Fadel, Elie; Hörer, Jürgen; Hascoët, Sébastien

    2017-05-01

    With the advances in congenital cardiac surgery and postoperative care, an increasing number of children with complex congenital heart disease now reach adulthood. There are already more adults than children living with a congenital heart defect, including patients with complex congenital heart defects. Among these adults with congenital heart disease, a significant number will develop ventricular dysfunction over time. Heart failure accounts for 26-42% of deaths in adults with congenital heart defects. Heart transplantation, or heart-lung transplantation in Eisenmenger syndrome, then becomes the ultimate therapeutic possibility for these patients. This population is deemed to be at high risk of mortality after heart transplantation, although their long-term survival is similar to that of patients transplanted for other reasons. Indeed, heart transplantation in adults with congenital heart disease is often challenging, because of several potential problems: complex cardiac and vascular anatomy, multiple previous palliative and corrective surgeries, and effects on other organs (kidney, liver, lungs) of long-standing cardiac dysfunction or cyanosis, with frequent elevation of pulmonary vascular resistance. In this review, we focus on the specific problems relating to heart and heart-lung transplantation in this population, revisit the indications/contraindications, and update the long-term outcomes. Copyright © 2017. Published by Elsevier Masson SAS.

  3. Ischaemic heart disease mortality and the business cycle in Australia.

    Science.gov (United States)

    Bunn, A R

    1979-01-01

    Trends in Australian heart disease mortality were assessed for association with the business cycle. Correlation models of mortality and unemployment series were used to test for association. An indicator series of "national stress" was developed. The three series were analyzed in path models to quantify the links between unemployment, national stress, and heart disease. Ischemic heart disease (IHD) mortality and national stress were found to follow the business cycle. The two periods of accelerating IHD mortality coincided with economic recession. The proposed "wave hypothesis" links the trend in IHD mortality to the high unemployment of severe recession. The mortality trend describes a typical epidemic parabolic path from the Great Depression to 1975, with a smaller parabolic trend at the 1961 recession. These findings appear consistent with the hypothesis that heart disease is, to some degree, a point source epidemic arising with periods of severe economic recession. Forecasts under the hypothesis indicate a turning point in the mortality trend between 1976 and 1978. (Am J Public Health 69:772-781, 1979). PMID:453409

  4. Study of Nicorandil stress perfusion MRI in diagnosing ischemic heart disease

    International Nuclear Information System (INIS)

    Tateishi, Toshiki; Iwai, Mitsuhiro; Takeda, Soji; Hayashi, Ryuji

    2006-01-01

    The excellent spatial resolution of myocardial stress perfusion magnetic resonance imaging is effective for the diagnosis of ischemic heart disease. When dipyridamole or adenosine triphosphate is used as a pharmacological stress in cardiac MRI, non-magnetic instruments are required for infusion of these drugs in a MRI room. We attempted to use nicorandil as a pharmacological stressor. Nicorandil exhibited KATP channel opening and nitrate effects, and could be infused without any special instruments. Based on the coronary artery stenosis assessed by coronary angiography, according to the criteria of the American Heart Association (AHA), the sensitivity, specificity and diagnostic accuracy of nicorandil perfusion MRI for the detection of coronary artery stenosis was 85%, 57% and 74.3%, respectively. No major side effects were observed, except for mild hypotension (mean 10 mmHg) after infusion of the drug. It was concluded that myocardial perfusion MRI examination using nicorandil could be performed non-invasively and safely for the evaluation of coronary vessel disease in patients. (author)

  5. Thigh circumference and risk of heart disease and premature death

    DEFF Research Database (Denmark)

    Heitmann, Berit L; Frederiksen, Peder

    2009-01-01

    of follow-up for total death. RESULTS: A small thigh circumference was associated with an increased risk of cardiovascular and coronary heart diseases and total mortality in both men and women. A threshold effect for thigh circumference was evident, with greatly increased risk of premature death below...... circumference seems to be associated with an increased risk of developing heart disease or premature death. The adverse effects of small thighs might be related to too little muscle mass in the region. The measure of thigh circumference might be a relevant anthropometric measure to help general practitioners...... in early identification of individuals at an increased risk of premature morbidity and mortality....

  6. Nuclear reactor construction with bottom supported reactor vessel

    International Nuclear Information System (INIS)

    Sharbaugh, J.E.

    1987-01-01

    This patent describes an improved liquid metal nuclear reactor construction comprising: (a) a nuclear reactor core having a bottom platform support structure; (b) a reactor vessel for holding a large pool of low pressure liquid metal coolant and housing the core; (c) a containment structure surrounding the reactor vessel and having a sidewall spaced outwardly from the reactor vessel side wall and having a base mat spaced below the reactor vessel bottom end wall; (d) a central small diameter post anchored to the containment structure base mat and extending upwardly to the reactor vessel to axially fix the bottom end wall of the reactor vessel and provide a center column support for the lower end of the reactor core; (e) annular support structure disposed in the reactor vessel on the bottom end wall and extending about the lower end of the core; (f) structural support means disposed between the containment structure base mat and bottom end of the reactor vessel wall and cooperating for supporting the reactor vessel at its bottom end wall on the containment structure base mat to allow the reactor vessel to expand radially but substantially prevent any lateral motions that might be imposed by the occurrence of a seismic event; (g) a bed of insulating material disposed between the containment structure base mat and the bottom end wall of the reactor vessel and uniformly supporting the reactor vessel at its bottom end wall; freely expand radially from the central post as it heats up while providing continuous support thereof; (h) a deck supported upon the wall of the containment vessel above the top open end of the reactor vessel; and (i) extendible and retractable coupling means extending between the deck and the top open end of the reactor vessel and flexibly and sealably interconnecting the reactor vessel at its top end to the deck

  7. Did antepartum hypoxic insult caused by fetal vessel thrombosis influence the procalcitonin level in umbilical blood? A case report.

    Science.gov (United States)

    Kaneko, Masatoki; Yamauchi, Aya; Yamashita, Rie; Sato, Yuichiro; Kodama, Yuki; Sameshima, Hiroshi

    2015-11-01

    We report a case of marked elevation of the procalcitonin level in umbilical blood and neonatal blood at birth. The mother did not perceive fetal motion. Antepartum fetal heart rate monitoring showed a loss of variability and absence of acceleration. No fetal breathing movement, fetal movement, or fetal tone were observed by ultrasonography. The female neonate was delivered by cesarean section at 25 weeks of gestation, with birthweight 774 g. The umbilical arterial pH value at birth was 7.29. Mild elevation in interleukin-6 and tumor necrosis factor-α in umbilical blood were observed. Cytochrome c showed a high level in umbilical and neonatal blood at birth. Placental histopathology revealed multiple fetal vessel thrombosis in the large stem villi and chorionic vessels. The neonate showed no infectious signs throughout the neonatal period. Computed tomography at 3 months of age revealed atrophy in the cerebrum and cerebellum. At 1 year after birth, the infant showed spastic quadriplegia. In this case, antepartum asphyxia due to fetal vessel thrombosis may have influenced the elevation of procalcitonin level in umbilical blood and neonatal blood at birth. © 2015 Japan Society of Obstetrics and Gynecology.

  8. Women's Heart Disease: Heart Attack Symptoms

    Science.gov (United States)

    ... of this page please turn JavaScript on. Feature: Women's Heart Disease Heart Attack Symptoms Past Issues / Winter ... most common heart attack symptom in men and women is chest pain or discomfort. However, women also ...

  9. Vacuum vessel for thermonuclear device

    International Nuclear Information System (INIS)

    Kikuchi, Mitsuru; Nagashima, Keisuke; Suzuki, Masaru; Onozuka, Masaki.

    1997-01-01

    A vacuum vessel main body and structural members at the inside and the outside of the vacuum vessel main body are constituted by structural materials activated by irradiation of neutrons from plasmas such as stainless steels. Shielding members comprising tungsten or molybdenum are disposed on the surface of the vacuum vessel main body and the structural members of the inside and the outside of the main body. The shielding members have a function also as first walls or a seat member for the first walls. Armor tiles may be disposed to the shielding members. The shielding members and the armor tiles are secured to a securing seat member disposed, for example, to an inner plate of the vacuum vessel main body by bolts. Since the shielding members are disposed, it is not necessary to constitute the vacuum vessel main body and the structural members at the inside and the outside thereof by using a low activation material which is less activated, such as a titanium alloy. (I.N.)

  10. Vacuum vessel for thermonuclear device

    Energy Technology Data Exchange (ETDEWEB)

    Kikuchi, Mitsuru; Nagashima, Keisuke [Japan Atomic Energy Research Inst., Tokyo (Japan); Suzuki, Masaru; Onozuka, Masaki

    1997-07-11

    A vacuum vessel main body and structural members at the inside and the outside of the vacuum vessel main body are constituted by structural materials activated by irradiation of neutrons from plasmas such as stainless steels. Shielding members comprising tungsten or molybdenum are disposed on the surface of the vacuum vessel main body and the structural members of the inside and the outside of the main body. The shielding members have a function also as first walls or a seat member for the first walls. Armor tiles may be disposed to the shielding members. The shielding members and the armor tiles are secured to a securing seat member disposed, for example, to an inner plate of the vacuum vessel main body by bolts. Since the shielding members are disposed, it is not necessary to constitute the vacuum vessel main body and the structural members at the inside and the outside thereof by using a low activation material which is less activated, such as a titanium alloy. (I.N.)

  11. Magnetic resonance imaging in patients with valvular heart disease

    International Nuclear Information System (INIS)

    Sechtem, U.; Welslau, R.; Hilger, H.H.; Theissen, P.; Jungehuelsing, M.; Schicha, H.

    1989-01-01

    In spite of the great number of imaging procedures available, it is still difficult to quantify the severity of valvular heart disease. Dynamic MRI offers new approaches to visualize the turbulent blood flow through stenosed or insufficient heart valves. In addition, it is possible to assess the severity of valvular insufficiency based on precise measurements of rigth- and left-ventricular stroke volumes or of systemic and pulmonary flow. Valvular stenoses are difficult to quantify by MRI because flow velocity measurements based on phase analysis can only be made at low flow rates at present. Some progress may be achieved by further shortening of echo times. In patients with cardiac valve replacement MRI is often superior to other imaging procedures because variable imaging planes facilitate differentiation between transvalvular and paravalvular leaks. Additionally, the severity of valvular incompetence can be assessed in such cases in the same way as in patients with insufficiency of the native heart valve. (orig.) [de

  12. A mathematical model for pressure-based organs behaving as biological pressure vessels.

    Science.gov (United States)

    Casha, Aaron R; Camilleri, Liberato; Gauci, Marilyn; Gatt, Ruben; Sladden, David; Chetcuti, Stanley; Grima, Joseph N

    2018-04-26

    We introduce a mathematical model that describes the allometry of physical characteristics of hollow organs behaving as pressure vessels based on the physics of ideal pressure vessels. The model was validated by studying parameters such as body and organ mass, systolic and diastolic pressures, internal and external dimensions, pressurization energy and organ energy output measurements of pressure-based organs in a wide range of mammals and birds. Seven rules were derived that govern amongst others, lack of size efficiency on scaling to larger organ sizes, matching organ size in the same species, equal relative efficiency in pressurization energy across species and direct size matching between organ mass and mass of contents. The lung, heart and bladder follow these predicted theoretical relationships with a similar relative efficiency across various mammalian and avian species; an exception is cardiac output in mammals with a mass exceeding 10kg. This may limit massive body size in mammals, breaking Cope's rule that populations evolve to increase in body size over time. Such a limit was not found in large flightless birds exceeding 100kg, leading to speculation about unlimited dinosaur size should dinosaurs carry avian-like cardiac characteristics. Copyright © 2018. Published by Elsevier Ltd.

  13. Analysis and optimization on in-vessel inspection robotic system for EAST

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Weijun, E-mail: zhangweijun@sjtu.edu.cn; Zhou, Zeyu; Yuan, Jianjun; Du, Liang; Mao, Ziming

    2015-12-15

    Since China has successfully built her first Experimental Advanced Superconducting TOKAMAK (EAST) several years ago, great interest and demand have been increasing in robotic in-vessel inspection/operation systems, by which an observation of in-vessel physical phenomenon, collection of visual information, 3D mapping and localization, even maintenance are to be possible. However, it has been raising many challenges to implement a practical and robust robotic system, due to a lot of complex constraints and expectations, e.g., high remanent working temperature (100 °C) and vacuum (10{sup −3} pa) environment even in the rest interval between plasma discharge experiments, close-up and precise inspection, operation efficiency, besides a general kinematic requirement of D shape irregular vessel. In this paper we propose an upgraded robotic system with redundant degrees of freedom (DOF) manipulator combined with a binocular vision system at the tip and a virtual reality system. A comprehensive comparison and discussion are given on the necessity and main function of the binocular vision system, path planning for inspection, fast localization, inspection efficiency and success rate in time, optimization of kinematic configuration, and the possibility of underactuated mechanism. A detailed design, implementation, and experiments of the binocular vision system together with the recent development progress of the whole robotic system are reported in the later part of the paper, while, future work and expectation are described in the end.

  14. Vessels in Transit - Web Tool

    Data.gov (United States)

    Department of Transportation — A web tool that provides real-time information on vessels transiting the Saint Lawrence Seaway. Visitors may sort by order of turn, vessel name, or last location in...

  15. High-performance fiber/epoxy composite pressure vessels

    Science.gov (United States)

    Chiao, T. T.; Hamstad, M. A.; Jessop, E. S.; Toland, R. H.

    1978-01-01

    Activities described include: (1) determining the applicability of an ultrahigh-strength graphite fiber to composite pressure vessels; (2) defining the fatigue performance of thin-titanium-lined, high-strength graphite/epoxy pressure vessel; (3) selecting epoxy resin systems suitable for filament winding; (4) studying the fatigue life potential of Kevlar 49/epoxy pressure vessels; and (5) developing polymer liners for composite pressure vessels. Kevlar 49/epoxy and graphite fiber/epoxy pressure vessels, 10.2 cm in diameter, some with aluminum liners and some with alternation layers of rubber and polymer were fabricated. To determine liner performance, vessels were subjected to gas permeation tests, fatigue cycling, and burst tests, measuring composite performance, fatigue life, and leak rates. Both the metal and the rubber/polymer liner performed well. Proportionately larger pressure vessels (20.3 and 38 cm in diameter) were made and subjected to the same tests. In these larger vessels, line leakage problems with both liners developed the causes of the leaks were identified and some solutions to such liner problems are recommended.

  16. Reactor vessel supported by flexure member

    International Nuclear Information System (INIS)

    Crawford, J.D.; Pankow, B.

    1975-01-01

    A description is given of a reactor pressure vessel which is provided with vertical support means in the form of circumferentially spaced columns upon which the vessel is mounted. The columns are adapted to undergo flexure in order to accommodate the thermally induced displacements experienced by the vessel during operational transients

  17. 50 CFR 648.4 - Vessel permits.

    Science.gov (United States)

    2010-10-01

    ... carrying passengers for hire. (8) Atlantic bluefish vessels. (i) Commercial. Any vessel of the United... lands Atlantic bluefish in or from the EEZ in excess of the recreational possession limit specified at § 648.164 must have been issued and carry on board a valid commercial bluefish vessel permit. (ii) Party...

  18. Coronary Heart Disease: Pandemic in a True Sense

    Directory of Open Access Journals (Sweden)

    Saurabh RamBihariLal Shrivastava

    2013-09-01

    Full Text Available Cardiovascular diseases are caused because of abnormalities in the heart and blood vessels. Recent trends reveal that the incidence of coronary heart disease (CHD has gradually decreased in many developed countries, but the situation remains quite challenging in developing nations that account for more than 60% of the global burden. Multiple socio-demographic, personal, physician related and healthcare delivery system related factors have been identified which act in variable combinations to either influence the incidence of CHD or affect the short/long-term outcome of the disease. Of all CHD cases who succumb within 28 days of onset of symptoms, almost 67% fail to reach even a hospital. This clearly signifies the importance of primary prevention and early recognition of the warning signs in averting cause-specific mortality. The main priority is to develop cost-effective equitable health care innovations in CHD prevention and to monitor the trend of CHD so that evidence-based interventions can be formulated. To conclude, inculcating health-promoting behaviors in school children and the general population by means of community-based health screening and education interventions could avert many more deaths attributed to CHDs.

  19. Coronary heart disease: pandemic in a true sense.

    Science.gov (United States)

    Rambiharilal Shrivastava, Saurabh; Saurabh Shrivastava, Prateek; Ramasamy, Jegadeesh

    2013-01-01

    Cardiovascular diseases are caused because of abnormalities in the heart and blood vessels. Recent trends reveal that the incidence of coronary heart disease (CHD) has gradually decreased in many developed countries, but the situation remains quite challenging in developing nations that account for more than 60% of the global burden. Multiple socio-demographic, personal, physician related and healthcare delivery system related factors have been identified which act in variable combinations to either influence the incidence of CHD or affect the short/long-term outcome of the disease. Of all CHD cases who succumb within 28 days of onset of symptoms, almost 67% fail to reach even a hospital. This clearly signifies the importance of primary prevention and early recognition of the warning signs in averting cause-specific mortality. The main priority is to develop cost-effective equitable health care innovations in CHD prevention and to monitor the trend of CHD so that evidence-based interventions can be formulated. To conclude, inculcating health-promoting behaviors in school children and the general population by means of community-based health screening and education interventions could avert many more deaths attributed to CHDs.

  20. Echocardiographic and radiographic findings in a cohort of healthy adult green iguanas (Iguana iguana).

    Science.gov (United States)

    Gustavsen, Kate A; Saunders, Ashley B; Young, Benjamin D; Winter, Randolph L; Hoppes, Sharman M

    2014-09-01

    To describe characteristics of echocardiography and cranial coelomic radiography in a cohort of iguanas. Twenty apparently healthy adult green iguanas (Iguana iguana) from a reptile sanctuary. Physical examination, radiography, two-dimensional and color Doppler echocardiography were performed to assess cardiac structures and function, and any related normal or abnormal findings were recorded. Echocardiographic examination was possible without sedation and allowed visualization of the great vessels, atria, and ventricle. Some structures could not be evaluated in a minority of the iguanas due to individual differences in bony conformation and imaging quality. Suspected abnormal echocardiographic findings in 3 iguanas included pericardial effusion (n = 1) and enlarged caudal vena cava and/or sinus venosus (n = 2). Objective measurements were repeatable as assessed by within-subject coefficient of variation, and reliable as assessed by intra-observer intraclass correlation coefficient. Left atrial and ventricular measurements were significantly correlated with body weight. Valve regurgitation was common, with atrioventricular valve regurgitation present in 53% (9/17) and aortic or pulmonic valve regurgitation in 71% (12/17) of otherwise normal iguanas. A heart murmur was not appreciated during examination of any of the iguanas. Heart size cannot be measured radiographically due to superimposition and silhouetting of other coelomic structures. Echocardiographic or radiographic findings consistent with mineralization of the great vessels were present in 76% of iguanas (13/17). Echocardiography in iguanas is well tolerated without sedation and allowed both subjective evaluation and structural measurements. Valve regurgitation and great vessel mineralization were commonly observed in this cohort of apparently healthy adult iguanas. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Histomorphological changes of vessel structure in head and neck vessels following preoperative or postoperative radiotherapy

    International Nuclear Information System (INIS)

    Schultze-Mosgau, S.; Wehrhan, F.; Wiltfang, J.; Grabenbauer, G.G.; Sauer, R.; Roedel, F.; Radespiel-Troeger, M.

    2002-01-01

    Patients and Methods: In 348 patients (October 1995-March 2002) receiving primarly or secondarily 356 microvascular hard- and soft tissue reconstruction, a total of 209 vessels were obtained from neck recipient vessels and transplant vessels during anastomosis. Three groups were analysed: group 1 (27 patients) treated with no radiotherapy or chemotherapy; group 2 (29 patients) treated with preoperative irradiation (40-50 Gy) and chemotherapy (800 mg/m 2 /day 5-FU and 20 mg/m 2 /day cisplatin) 1.5 months prior to surgery; group 3 (20 patients) treated with radiotherapy (60-70 Gy) (median interval 78.7 months; IQR: 31.3 months) prior to surgery. From each of the 209 vessel specimens, 3 sections were investigated histomorphometrically, qualitatively and quantitatively (ratio media area/total vessel area) by NIH-Image-digitized measurements. To evaluate these changes as a function of age, radiation dose and chemotherapy, a statistical analysis was performed using an analysis of covariance and χ 2 tests (p > 0.05, SPSS V10). Results: In group 3, qualitative changes (intima dehiscence, hyalinosis) were found in recipient arteries significantly more frequently than in groups 1 and 2. For group 3 recipient arteries, histomorphometry revealed a significant decrease in the ratio media area/total vessel area (median 0.51, IQR 0.10) in comparison with groups 1 (p = 0.02) (median 0.61, IQR 0.29) and 2 (p = 0.046) (median 0.58, IQR 0.19). No significant difference was found between the vessels of groups 1 and 2 (p = 0.48). There were no significant differences in transplant arteries and recipient or transplant veins between the groups. Age and chemotherapy did not appear to have a significant influence on vessel changes in this study (p > 0.05). Conclusions: Following irradiation with 60-70 Gy, significant qualitative and quantitative histological changes to the recipient arteries, but not to the recipient veins, could be observed. In contrast, irradiation at a dose of 40-50 Gy

  2. Peptidomics Analysis of Transient Regeneration in the Neonatal Mouse Heart.

    Science.gov (United States)

    Fan, Yi; Zhang, Qijun; Li, Hua; Cheng, Zijie; Li, Xing; Chen, Yumei; Shen, Yahui; Wang, Liansheng; Song, Guixian; Qian, Lingmei

    2017-09-01

    Neonatal mouse hearts have completely regenerative capability after birth, but the ability to regenerate rapidly lost after 7 days, the mechanism has not been clarified. Previous studies have shown that mRNA profile of adult mouse changed greatly compared to neonatal mouse. So far, there is no research of peptidomics related to heart regeneration. In order to explore the changes of proteins, enzymes, and peptides related to the transient regeneration, we used comparative petidomics technique to compare the endogenous peptides in the mouse heart of postnatal 1 and 7 days. In final, we identified 236 differentially expressed peptides, 169 of which were upregulated and 67 were downregulated in the postnatal 1 day heart, and also predicted 36 functional peptides associated with transient regeneration. The predicted 36 candidate peptides are located in the important domains of precursor proteins and/or contain the post-transcriptional modification (PTM) sites, which are involved in the biological processes of cardiac development, cardiac muscle disease, cell proliferation, necrosis, and apoptosis. In conclusion, for the first time, we compared the peptidomics profiles of neonatal heart between postnatal 1 day and postnatal 7 day. This study provides a new direction and an important basis for the mechanism research of transient regeneration in neonatal heart. J. Cell. Biochem. 118: 2828-2840, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  3. In-vessel core debris retention through external flooding of the reactor pressure vessel. State-of-the-art report

    Energy Technology Data Exchange (ETDEWEB)

    Heel, A.M.J.M. van

    1995-07-01

    An overview of the state-of-the-art knowledge on the ex-vessel flooding accident management strategy for severe accidents in a NPP has been given. The feasibility has been discussed, as well as the in- and ex-vessel phenomena, which influence the structural integrity of the vessel. Finally, some computer codes with the ability to model the phenomena involved in ex-vessel flooding have been discussed. (orig./HP).

  4. In-vessel core debris retention through external flooding of the reactor pressure vessel. State-of-the-art report

    International Nuclear Information System (INIS)

    Heel, A.M.J.M. van.

    1995-07-01

    An overview of the state-of-the-art knowledge on the ex-vessel flooding accident management strategy for severe accidents in a NPP has been given. The feasibility has been discussed, as well as the in- and ex-vessel phenomena, which influence the structural integrity of the vessel. Finally, some computer codes with the ability to model the phenomena involved in ex-vessel flooding have been discussed. (orig./HP)

  5. Vacuum vessel for thermonuclear device

    International Nuclear Information System (INIS)

    Hagiwara, Koji; Imura, Yasuya.

    1979-01-01

    Purpose: To provide constituted method for easily performing baking of vacuum vessel, using short-circuiting segments. Constitution: At the time of baking, one turn circuit is formed by the vacuum vessel and short-circuiting segments, and current transformer converting the one turn circuit into a secondary circuit by the primary coil and iron core is formed, and the vacuum vessel is Joule heated by an induction current from the primary coil. After completion of baking, the short-circuiting segments are removed. (Kamimura, M.)

  6. Development of heat transfer enhancement techniques for external cooling of an advanced reactor vessel

    Science.gov (United States)

    Yang, Jun

    coatings by comparing the measurements with those for a plain vessel without coatings. An overall enhancement in nucleate boiling rates and CHF limits up to 100% were observed. Moreover, combination of data from quenching experiments and steady-state experiments produced new sets of boiling curves, which covered both the nucleate and transient boiling regimes with much greater accuracy. Beside the experimental work, a theoretical CHF model has also been developed by considering the vapor dynamics and the boiling-induced two-phase motions in three separate regions adjacent to the heating surface. The CHF model is capable of predicting the performance of micro-porous coatings with given particle diameter, porosity, media permeability and thickness. It is found that the present CHF model agrees favorably with the experimental data. Effects of an enhanced vessel/insulation structure on the local nucleate boiling rate and CHF limit have also been investigated experimentally. It is observed that the local two-phase flow quantities such as the local void fraction, quality, mean vapor velocity, mean liquid velocity, and mean vapor and liquid mass flow rates could have great impact on the local surface heat flux as boiling of water takes place on the vessel surface. An upward co-current two-phase flow model has been developed to predict the local two-phase flow behavior for different flow channel geometries, which are set by the design of insulation structures. It is found from the two-phase flow visualization experiments and the two-phase flow model calculations that the enhanced vessel/insulation structure greatly improved the steam venting process at the minimum gap location compared to the performance of thermal insulation structures without enhancement. Moveover, depending on the angular location, steady-state boiling experiments with the enhanced insulation design showed an enhancement of 1.8 to 3.0 times in the local critical heat flux. Finally, nucleate boiling and CHF

  7. Analyses of Trawling Track and Fishing Activity Based on the Data of Vessel Monitoring System (VMS):A Case Study of the Single Otter Trawl Vessels in the Zhoushan Fishing Ground

    Institute of Scientific and Technical Information of China (English)

    WANG Yang; WANG Yingbin; ZHENG Ji

    2015-01-01

    The original purpose of Vessel Monitoring System (VMS) is for enforcement and control of vessel sailing. With the ap-plication of VMS in fishing vessels, more and more population dynamic studies have used VMS data to improve the accuracy of fisheries stock assessment. In this paper, we simulated the trawl trajectory under different time intervals using the cubic Hermite spline (cHs) interpolation method based on the VMS data of 8 single otter trawl vessels (totally 36000 data items) fishing in Zhou-shan fishing ground from September 2012 to December 2012, and selected the appropriate time interval. We then determined vessels’ activities (fishing or non-fishing) by comparing VMS speed data with the corresponding speeds from logbooks. The results showed that the error of simulated trajectory greatly increased with the increase of time intervals of VMS data when they were longer than 30 minutes. Comparing the speeds from VMS with those from the corresponding logbooks, we found that the vessels’ speeds were be-tween 2.5kn and 5.0kn in fishing. The cHs interpolation method is a new choice for improving the accuracy of estimation of sailing trajectory, and the VMS can be used to determine the vessels’ activities with the analysis of their trajectories and speeds. Therefore, when the fishery information is limited, VMS can be one of the important data sources for fisheries stock assessment, and more at-tention should be paid to its construction and application to fisheries stock assessment and management.

  8. Hydroxytyrosol and its complex forms (secoiridoids) modulate aorta and heart proteome in healthy rats: Potential cardio-protective effects.

    Science.gov (United States)

    Catalán, Úrsula; Rubió, Laura; López de Las Hazas, Maria-Carmen; Herrero, Pol; Nadal, Pedro; Canela, Núria; Pedret, Anna; Motilva, Maria-José; Solà, Rosa

    2016-10-01

    Hydroxytyrosol (HT) is the major phenolic compound in virgin olive oil (VOO) in both free and complex forms (secoiridoids; SEC). Proteomics of cardiovascular tissues such as aorta or heart represents a promising tool to uncover the mechanisms of action of phenolic compounds in healthy animals. Twelve female Wistar rats were separated into three groups: a standard diet and two diets supplemented in phenolic compounds (HT and SEC) adjusted to 5 mg/kg/day during 21 days. Proteomic analyses of aorta and heart tissues were performed by nano-LC and MS. Ingenuity Pathway Analysis was used to generate interaction networks. HT or SEC modulated aorta and heart proteome compared to the standard diet. The top-scored networks were related to Cardiovascular System. HT and SEC downregulated proteins related to proliferation and migration of endothelial cells and occlusion of blood vessels in aorta and proteins related to heart failure in heart tissue. SEC showed higher fold change values compared to HT, attributed to higher concentration of HT detected in heart tissue. Changes at proteomic level in cardiovascular tissues may partially account for the underlying mechanisms of VOO phenols cardiovascular protection being the SEC effects higher than free HT. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Structural analysis of the KSTAR vacuum vessel

    Energy Technology Data Exchange (ETDEWEB)

    In, Sang Ryul; Yoon, Byeong Joo [Korea Atomic Energy Research Institute, Taejon (Korea)

    1998-10-01

    Structure analysis of the vacuum vessel for the KSTAR tokamak which, is in the end phase of the conceptual design have been performed. Mechanical stresses and deformations of the vessel produced by constant forces due to atmospheric pressure, dead weight, fluid pressure, etc and various transient electromagnetic forces induced during tokamak operations were calculated as well as modal characteristics and buckling properties were investigated. Influences of the temperature gradient and the constraint condition of the support on the thermal stress and deformation of the vessel were analyzed. The thermal stress due to the temperature distribution on the vessel as supplying the N{sub 2} gas of 400 deg C through poloidal channels according to the recent baking concept were calculated. No severe problem in the robustness of the vessel was found when applying the constant pressures on the vessel. However the mechanical stress due to the EM force induced by halo currents flowing on the vessel and the plasma facing components (PFCs) far exceeded the allowable limit. Some reinforcing components should be added on the boundary of the PFC support and the vessel, and that of the vessel support and the vessel. A steep temperature gradient in the vicinity of the inlet and oulet of the heating gas produced a thermal stress much higher than allowable. It is necessary to make the temperature of the vessel as uniform as possible and to develop a new support concept which is flexible enough to accommodate a thermal expansion of a few cm while sufficiently strong to resist mechanical impacts. (author). 5 refs., 41 figs., 9 tabs.

  10. Pressure vessels and methods of sealing leaky tubes disposed in pressure vessels

    International Nuclear Information System (INIS)

    Larson, G.C.

    1980-01-01

    This invention relates to pressure vessels and to methods of sealing leaky tubes in them and is especially applicable to pressure vessels in the form of sheet-and-tube type heat exchangers constructed with a large number of relatively small diameter tubes grouped in a bundle. To seal off a leaky tube in such a heat exchanger an explosive activated plug in the form of a hollow metal body is used, inserted at each end of the tube to be sealed. Using the arrangement of pressure vessel and associated tube sheets and the explosive activated plug method of sealing a leaky tube as described in this invention it is claimed that distortion of the adjacent tubes and the tube sheets is reduced when the explosive activated plugs are detonated. (U.K.)

  11. Great auricular nerve involvement in leprosy: Scope for misdiagnosis

    Directory of Open Access Journals (Sweden)

    Ramesh V

    2007-01-01

    Full Text Available Three patients with neuritis of the great auricular nerve (GAN have been reported. Two patients seen by physicians and an otolaryngologist had prominent and tender cord along the neck with facial edema and history of fainting attack in one, and erythema and hyperaesthesia of the ear in the other simulating vascular occlusion, which were confirmed to be leprosy in Type 1 reaction by the dermatologist. In the third, cold abscess in the nerve that had persisted after anti-leprosy treatment was mistaken as tuberculous cervical lymphadenitis by a surgeon since aspiration had revealed acid-fast bacilli. The probable reasons for misdiagnosis include rarity of involvement of the GAN and its proximity to main blood vessels, and the need for careful interpretation of laboratory results.

  12. 33 CFR 151.1512 - Vessel safety.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Vessel safety. 151.1512 Section... River § 151.1512 Vessel safety. Nothing in this subpart relieves the master of the responsibility for ensuring the safety and stability of the vessel or the safety of the crew and passengers, or any other...

  13. Characteristics analysis on a superconductor resonance coil WPT system according to cooling vessel materials in different distances

    International Nuclear Information System (INIS)

    Jeong, In-Sung; Lee, Yu-Kyeong; Choi, Hyo-Sang

    2016-01-01

    Highlights: • WPT using the superconductor coil was needed research for cooling vessel. FRP, bakelite, polystyrene, aluminum, and iron were applied as the cooling vessel material to analyze the WPT distance efficiency. • When the distance between the transmitter and receiver coils was 2000 mm, FRP being used for the cooling vessel made the transmission efficiency higher than any other materials. The efficiency and distance of sending power can be improved in the superconductor coil if the cooling vessel is made with FRP. - Abstract: The interest in wireless power transfer (WPT) that can send power without using wires has been increasing recently. Especially, there is a great interest in the wireless power devices for portable IT devices. The WPT devices that have been developed so far use the magnetic induction method, and they are not active due to their distance problem. A magnetic resonance WPT method was developed and has been actively researched to resolve this problem. A superconductor coil was applied in this study to increase the efficiency of the magnetic resonance WPT. FRP, bakelite, polystyrene, aluminum, and iron were applied as the cooling vessel material to analyze the WPT distance. The distance between the transmitter and receiver coils started from 800 mm and was increased by 200 mm. The reflection coefficient was measured at each distance. As a result, FRP, bakelite, plastic PVC, polystyrene of the reflection coefficient was similar. From among these FRP being used for the cooling vessel made the transmission characteristics higher than any other materials when the distance between the transmitter and receiver coils was 2,000 mm. On the other hand, the reflection coefficient dropped when iron was used. It is estimated based on the experimental results that the wireless power transmission characteristics and distance of sending power can be improved in the superconductor coil if the cooling vessel is made with FRP.

  14. Characteristics analysis on a superconductor resonance coil WPT system according to cooling vessel materials in different distances

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, In-Sung, E-mail: no21park@hanmail.net; Lee, Yu-Kyeong; Choi, Hyo-Sang, E-mail: hyosang@chosun.ac.kr

    2016-11-15

    Highlights: • WPT using the superconductor coil was needed research for cooling vessel. FRP, bakelite, polystyrene, aluminum, and iron were applied as the cooling vessel material to analyze the WPT distance efficiency. • When the distance between the transmitter and receiver coils was 2000 mm, FRP being used for the cooling vessel made the transmission efficiency higher than any other materials. The efficiency and distance of sending power can be improved in the superconductor coil if the cooling vessel is made with FRP. - Abstract: The interest in wireless power transfer (WPT) that can send power without using wires has been increasing recently. Especially, there is a great interest in the wireless power devices for portable IT devices. The WPT devices that have been developed so far use the magnetic induction method, and they are not active due to their distance problem. A magnetic resonance WPT method was developed and has been actively researched to resolve this problem. A superconductor coil was applied in this study to increase the efficiency of the magnetic resonance WPT. FRP, bakelite, polystyrene, aluminum, and iron were applied as the cooling vessel material to analyze the WPT distance. The distance between the transmitter and receiver coils started from 800 mm and was increased by 200 mm. The reflection coefficient was measured at each distance. As a result, FRP, bakelite, plastic PVC, polystyrene of the reflection coefficient was similar. From among these FRP being used for the cooling vessel made the transmission characteristics higher than any other materials when the distance between the transmitter and receiver coils was 2,000 mm. On the other hand, the reflection coefficient dropped when iron was used. It is estimated based on the experimental results that the wireless power transmission characteristics and distance of sending power can be improved in the superconductor coil if the cooling vessel is made with FRP.

  15. Vitamin D Status in Small Vessel and Large Vessel Ischemic Stroke Patients: A Case–control Study

    Directory of Open Access Journals (Sweden)

    Navid Manouchehri

    2017-01-01

    Full Text Available Background: Vitamin D insufficiency is a globally widespread issue. Recent studies have reported a high prevalence of Vitamin D deficiency in Middle-East countries. Studies have shown negative effects of Vitamin D deficiency on endothelium and related diseases such as ischemic brain stroke. Here, we assessed Vitamin D status in patients with different types of ischemic brain stroke and control group. Materials and Methods: Seventy-five patients (49.3% small vessel, 50.7% large vessel and 75 controls, matched for age (68.01 ± 10.94 vs. 67.64 ± 10.24 and sex (42 male and 33 female were recruited. 25(OH D levels were measured by Chemiluminescence immunoassay. 25(OH D status was considered as severely, moderately, or mildly deficient and normal with 25(OH D levels of less than 5, 5-10, 10-16, and> 16 ng/ml, respectively. Results: Mean ± standard error concentration of 25(OH D in cases and controls were 17.7 ± 1.5 and 26.9 ± 1.6 (P = 0.0001, respectively. Mild, moderate, and severe Vitamin D deficiency were observed in 10.8%, 32.4%, 8.1% vs. 34.3%, 31.5%, 9.5% of small vessel and large vessel group, respectively. 21.7% of the controls were Vitamin D deficient. Vitamin D deficiency was significantly associated with higher risk for ischemic stroke, (P = 0.000, OR = 7.17, 95% confidence interval: 3.36–15.29. 25(OH D levels were significantly higher in control group comparing to small vessel (26.9 ± 1.6 vs. 20.59 ± 2.6 P < 0.05 and large vessel (26.9 ± 1.6 vs. 13.4 ± 1.3 P < 0.001 stroke patients. Small vessel group had significantly higher levels of Vitamin D than large vessel (P < 0.05. Conclusion: Vitamin D deficiency significantly increases the risk of ischemic stroke, favoring the types with the pathogenesis of large vessel strokes.

  16. Use of automation and mechanization elements in welding and surfacing nuclear reactor pressure vessels

    International Nuclear Information System (INIS)

    Bartak, J.; Elckner, J.

    1986-01-01

    The problems are discussed of automation and mechanization of individual operations in the production cycle of pressure vessels whose manufacture cannot for its great exactingness be automated as a whole. Examples are given of workplaces and single-purpose welding facilities with a high level of automation. The present state of the development and implementation of automation of arc welding is described and further development is indicated of the automation of welding processes in the manufacture of nuclear facilities. (J.C.)

  17. AFSC/FMA/Vessel Assessment Logging

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Vessels fishing trawl gear, vessels fishing hook-and-line and pot gear that are also greater than 57.5 feet overall, and shoreside and floating processing facilities...

  18. REVIEWS OF BOOKS:BOEKRESENSIES

    African Journals Online (AJOL)

    (This work will consist of 8 Volumes at. £5 10s. Od. for each volume and an Index at £2 Os. Od.) London: Butterworth ... Section VI: Heart, Pericardium and Great Blood Vessels. ... of the Circulatory System. 2. Physiology. 3. .... tion, or, at least, suppression, is only a matter of time. ... Price £2 10s.• .... Part I.-General Principles.

  19. Monocephalus diprosopus, a rare form of conjoined twins, and associated congenital anomalies.

    Science.gov (United States)

    Rodríguez-Morales, Edda L; Correa-Rivas, María S; Colón-Castillo, Lillian E

    2002-09-01

    Craniofacial duplication (diprosopus) is a rare form of conjoined twins. A case of monocephalus diprosopus with anencephaly, cervicothoracolumbar rachischisis, and duplication of the respiratory tract and upper gastrointestinal tract is reported. The cardiovascular system remained single but the heart showed transposition of the great vessels. We present this case due to its rarity, and compare our pathologic findings with those already reported.

  20. Heart murmurs

    Science.gov (United States)

    Chest sounds - murmurs; Heart sounds - abnormal; Murmur - innocent; Innocent murmur; Systolic heart murmur; Diastolic heart murmur ... The heart has 4 chambers: Two upper chambers (atria) Two lower chambers (ventricles) The heart has valves that close ...

  1. Modeling the Role of the Glymphatic Pathway and Cerebral Blood Vessel Properties in Alzheimer's Disease Pathogenesis.

    Directory of Open Access Journals (Sweden)

    Christina Rose Kyrtsos

    Full Text Available Alzheimer's disease (AD is the most common cause of dementia in the elderly, affecting over 10% population over the age of 65 years. Clinically, AD is described by the symptom set of short term memory loss and cognitive decline, changes in mentation and behavior, and eventually long-term memory deficit as the disease progresses. On imaging studies, significant atrophy with subsequent increase in ventricular volume have been observed. Pathology on post-mortem brain specimens demonstrates the classic findings of increased beta amyloid (Aβ deposition and the presence of neurofibrillary tangles (NFTs within affected neurons. Neuroinflammation, dysregulation of blood-brain barrier transport and clearance, deposition of Aβ in cerebral blood vessels, vascular risk factors such as atherosclerosis and diabetes, and the presence of the apolipoprotein E4 allele have all been identified as playing possible roles in AD pathogenesis. Recent research has demonstrated the importance of the glymphatic system in the clearance of Aβ from the brain via the perivascular space surrounding cerebral blood vessels. Given the variety of hypotheses that have been proposed for AD pathogenesis, an interconnected, multilayer model offers a unique opportunity to combine these ideas into a single unifying model. Results of this model demonstrate the importance of vessel stiffness and heart rate in maintaining adequate clearance of Aβ from the brain.

  2. Situs Inversus with Levocardia and Congenitally Corrected Transposition of Great Vessels in a 35 year old Male: A Case report.

    Science.gov (United States)

    Ghorbnazadeh, Atefeh; Zirak, Nahid; Fazlinezhad, Afsoon; Moenipour, Aliasghar; Manshadi, Hamid Hoseinikhah; Teshnizi, Mohammad Abbasi

    2017-01-01

    Situs inversus with levocardia and congenitally corrected transposition of the great arteries represents a relatively very rare congenital condition and most patients are diagnosed in infancy or early age. This case report describes a 35-year old man with congenitally corrected transposition of the great arteries which presented with a five month history of exertional dyspnea. A diagnosis was confirmed by transesophageal echocardiogram, showing situs inversus, levocardia, atrioventricular and ventriculoarterial discordance. He underwent physiologic repair, and was discharged thirty five days after the operation, in a good general condition. Although management of the corrected transposition of the great arteries patients remains controversial, the recommendation is that physiologic repair may be the procedure of choice for some patients, particularly complicated cases.

  3. Vessel size measurements in angiograms: Manual measurements

    International Nuclear Information System (INIS)

    Hoffmann, Kenneth R.; Dmochowski, Jacek; Nazareth, Daryl P.; Miskolczi, Laszlo; Nemes, Balazs; Gopal, Anant; Wang Zhou; Rudin, Stephen; Bednarek, Daniel R.

    2003-01-01

    Vessel size measurement is perhaps the most often performed quantitative analysis in diagnostic and interventional angiography. Although automated vessel sizing techniques are generally considered to have good accuracy and precision, we have observed that clinicians rarely use these techniques in standard clinical practice, choosing to indicate the edges of vessels and catheters to determine sizes and calibrate magnifications, i.e., manual measurements. Thus, we undertook an investigation of the accuracy and precision of vessel sizes calculated from manually indicated edges of vessels. Manual measurements were performed by three neuroradiologists and three physicists. Vessel sizes ranged from 0.1-3.0 mm in simulation studies and 0.3-6.4 mm in phantom studies. Simulation resolution functions had full-widths-at-half-maximum (FWHM) ranging from 0.0 to 0.5 mm. Phantom studies were performed with 4.5 in., 6 in., 9 in., and 12 in. image intensifier modes, magnification factor = 1, with and without zooming. The accuracy and reproducibility of the measurements ranged from 0.1 to 0.2 mm, depending on vessel size, resolution, and pixel size, and zoom. These results indicate that manual measurements may have accuracies comparable to automated techniques for vessels with sizes greater than 1 mm, but that automated techniques which take into account the resolution function should be used for vessels with sizes smaller than 1 mm

  4. CLINICAL AND ANGIOGRAPHIC PROFILE OF PATIENTS WITH COMPLETE HEART BLOCK

    Directory of Open Access Journals (Sweden)

    Kavya Pingali

    2017-05-01

    Full Text Available BACKGROUND The angiographic findings and prognosis of patients with Complete Heart Block (CHB remain unclear. Thus, we aimed to study the clinical profile, risk factors, angiographic distribution and in-hospital outcomes of patients with complete heart block. MATERIALS AND METHODS This was a prospective, single-centred study which included 100 patients who came to the emergency department with CHB. Routine blood investigations including serum electrolytes were done. Coronary angiogram was done and lesions were assessed. Temporary pacemaker was implanted followed by permanent pacemakers in required patients, and in-hospital complications were noted down. RESULTS Commonest age group was above 60 years (75%. The patients were predominantly males. Most common presentation was chest pain (60%; there was regional wall motion abnormality in 30% patients. Degenerative complete heart block was seen in 34% patients, diphtheric myocarditis in 15%, hypokalaemic in 15%, dilated cardiomyopathy in 2%. Of total 53 patients had AV block, 14 had bifascicular block, 23 had LBBB, 6 had RBBB, 3 had Mobitz I and 1 had Mobitz II. Inferior wall myocardial infarction (MI was pervasively present in patients. Temporary pacemakers were implanted in 6 patients and permanent pacemakers in 43 patients. In-hospital outcomes constituted of complication like cardiogenic shock (10% and death (26%. The patients who died either had 80% -90% stenosis in RCA, triple vessel disease, ostioproximal LAD occlusion or diphtheric myocarditis. CONCLUSION Complete heart block was majorly associated with advanced age and inferior wall MI, virtually caused by dominant RCA occlusion. The in-hospital mortality was significantly higher in the patients with CHB.

  5. Churg-Strauss syndrome and persistent heart failure: active disease or damage?

    Science.gov (United States)

    Lin, Yih Chang; Oliveira, Guilherme H M; Villa-Forte, Alexandra

    2013-10-01

    Churg-Strauss syndrome (CSS) is a rare small-vessel vasculitis typically associated with adult-onset asthma, peripheral and tissue hypereosinophilia, migratory pulmonary infiltrates, upper respiratory tract symptoms, and clinical evidence of systemic vasculitis. Cardiac involvement is a well-recognized complication with an estimated prevalence of 60%. Heart disease is associated with poor prognosis, accounting for almost 50% mortality in CSS. We present a case of a 48-year-old woman with CSS complicated by congestive heart failure with left ventricular ejection fraction of 25%, who was initially treated with long course of high-dose steroids without any clinical or echocardiographic improvement. She was referred to our hospital 1 year later and was initiated with cyclophosphamide 2 mg/kg per day and prednisone 60 mg/d followed by slow taper. Subsequently, the patient had remarkable improvement. Patient was then transitioned to azathioprine for 1.5 years with sustained disease remission. It may be difficult to determine myocardial disease activity status versus tissue damage in CSS with prolonged duration of heart failure symptoms. This is the first case report demonstrating that CSS cardiac disease may remain active despite 1 year of corticosteroid therapy, and significant improvement or remission can still be achieved by administering more aggressive cytotoxic immunosuppressive therapy.

  6. Effects of electric paravertebral muscle relaxation processes in the athletes heart

    Directory of Open Access Journals (Sweden)

    D. V. Syshko

    2013-02-01

    Full Text Available Influence of paravertebrals miorelaxation on electric processes in a heart at sportsmen is studied. Paravertebrals miorelaxation was the complex of exercises in a water environment directed on the decline of tone of paravertebral muscles. Before and after it was used of paravertebrals miorelaxation registered the indexes of electrocardiography at the sportsmen engaged in the Greek-Roman fight (n=22 by football (n=24 and heavy athletics (n=25. It is got, that at the sportsmen of engaged in the Greek -Roman fight after paravertebrals miorelaxation QRS and QT were it was increased, and R-R and PQ went down. At the sportsmen of engaged in heavy athletics HR and PQ went down after paravertebrals miorelaxation, R-R, QRS and QT were it was increased. At the sportsmen of getting busy by football the PQ interval shortened, and QRS and QT has multiplied. Findings testify to the presence of different mechanisms of adaptation of the conducting system of heart in the conditions of influencing of paravertebrals miorelaxation. These distinctions are fated by two basic factors: by the functional being of the cardio-vessels system on the whole and functional being of sine knot and conducting system of heart in particular.

  7. Angiotensinergic and noradrenergic neurons in the rat and human heart.

    Science.gov (United States)

    Patil, Jaspal; Stucki, Silvan; Nussberger, Juerg; Schaffner, Thomas; Gygax, Susanne; Bohlender, Juergen; Imboden, Hans

    2011-02-25

    Although the physiological and pharmacological evidences suggest a role for angiotensin II (Ang II) with the mammalian heart, the source and precise location of Ang II are unknown. To visualize and quantitate Ang II in atria, ventricular walls and interventricular septum of the rat and human heart and to explore the feasibility of local Ang II production and function, we investigated by different methods the expression of proteins involved in the generation and function of Ang II. We found mRNA of angiotensinogen (Ang-N), of angiotensin converting enzyme, of the angiotensin type receptors AT(1A) and AT₂ (AT(1B) not detected) as well as of cathepsin D in any part of the hearts. No renin mRNA was traceable. Ang-N mRNA was visualized by in situ hybridization in atrial ganglial neurons. Ang II and dopamine-β-hydroxylase (DβH) were either colocalized inside the same neuronal cell or the neurons were specialized for Ang II or DβH. Within these neurons, the vesicular acetylcholine transporter (VAChT) was neither colocalized with Ang II nor DβH, but VAChT-staining was found with synapses en passant encircle these neuronal cells. The fibers containing Ang II exhibited with blood vessels and with cardiomyocytes supposedly angiotensinergic synapses en passant. In rat heart, right atrial median Ang II concentration appeared higher than septal and ventricular Ang II. The distinct colocalization of neuronal Ang II with DβH in the heart may indicate that Ang II participates together with norepinephrine in the regulation of cardiac functions: produced as a cardiac neurotransmitter Ang II may have inotropic, chronotropic or dromotropic effects in atria and ventricles and contributes to blood pressure regulation. Copyright © 2010 Elsevier B.V. All rights reserved.

  8. Assessment of reactor vessel integrity (ARVI)

    Energy Technology Data Exchange (ETDEWEB)

    Sehgal, B.R. E-mail: sehgal@ne.kth.se; Theerthan, A.; Giri, A.; Karbojian, A.; Willschuetz, H.G.; Kymaelaeinen, O.; Vandroux, S.; Bonnet, J.M.; Seiler, J.M.; Ikkonen, K.; Sairanen, R.; Bhandari, S.; Buerger, M.; Buck, M.; Widmann, W.; Dienstbier, J.; Techy, Z.; Kostka, P.; Taubner, R.; Theofanous, T.; Dinh, T.N

    2003-04-01

    The cost-shared project ARVI (assessment of reactor vessel integrity) involves a total of nine organisations from Europe and USA. The objective of the ARVI Project is to resolve the safety issues that remain unresolved for the melt vessel interaction phase of the in-vessel progression of a severe accident. The work consists of experiments and analysis development. Four tests were performed in the EC-FOREVER Programme, in which failure was achieved in-vessels employing the French pressure vessel steel. The tests were analysed with the commercial code ANSYS-Multiphysics, and the codes SYSTUS+ and PASULA, and quite good agreement was achieved for the failure location. Natural convection experiments in stratified pools have been performed in the SIMECO and the COPO facilities, which showed that much greater heat is transferred downwards for immiscible layers or before layers mix. A model for gap cooling and a set of simplified models for the system codes have been developed. MVITA code calculations have been performed for the Czech and Hungarian VVERs, towards evaluation of the in-vessel melt retention accident management scheme. Tests have been performed at the ULPU facility with organised flow for vessel external cooling. Considerable enhancement of the critical heat flux (CHF) was obtained. The ARVI Project has reached the halfway stage. This paper presents the results obtained thus far from the project.

  9. Neutron Assay System for Confinement Vessel Disposition

    International Nuclear Information System (INIS)

    Frame, Katherine C.; Bourne, Mark M.; Crooks, William J.; Evans, Louise; Mayo, Douglas R.; Miko, David K.; Salazar, William R.; Stange, Sy; Valdez, Jose I.; Vigil, Georgiana M.

    2012-01-01

    Los Alamos National Laboratory has a number of spherical confinement vessels (CVs) remaining from tests involving nuclear materials. These vessels have an inner diameter of 6 feet with 1-inch thick steel walls. The goal of the Confinement Vessel Disposition (CVD) project is to remove debris and reduce contamination inside the CVs. The Confinement Vessel Assay System (CVAS) was developed to measure the amount of special nuclear material (SNM) in CVs before and after cleanout. Prior to cleanout, the system will be used to perform a verification measurement of each vessel. After cleanout, the system will be used to perform safeguards-quality assays of (le)100-g 239 Pu equivalent in a vessel for safeguards termination. The CVAS has been tested and calibrated in preparation for verification and safeguards measurements.

  10. Containment vessel

    International Nuclear Information System (INIS)

    Zbirohowski-Koscia, K.F.; Roberts, A.C.

    1980-01-01

    A concrete containment vessel for nuclear reactors is disclosed that is spherical and that has prestressing tendons disposed in first, second and third sets, the tendons of each set being all substantially concentric and centred around a respective one of the three orthogonal axes of the sphere; the tendons of the first set being anchored at each end at a first anchor rib running around a circumference of the vessel, the tendons of the second set being anchored at each end at a second anchor rib running around a circumference of the sphere and disposed at 90 0 to the first rib, and the tendons of the third set being anchored some to the first rib and the remainder to the second rib. (author)

  11. Modeling the Human Scarred Heart In Vitro: Toward New Tissue Engineered Models.

    Science.gov (United States)

    Deddens, Janine C; Sadeghi, Amir Hossein; Hjortnaes, Jesper; van Laake, Linda W; Buijsrogge, Marc; Doevendans, Pieter A; Khademhosseini, Ali; Sluijter, Joost P G

    2017-02-01

    Cardiac remodeling is critical for effective tissue healing, however, excessive production and deposition of extracellular matrix components contribute to scarring and failing of the heart. Despite the fact that novel therapies have emerged, there are still no lifelong solutions for this problem. An urgent need exists to improve the understanding of adverse cardiac remodeling in order to develop new therapeutic interventions that will prevent, reverse, or regenerate the fibrotic changes in the failing heart. With recent advances in both disease biology and cardiac tissue engineering, the translation of fundamental laboratory research toward the treatment of chronic heart failure patients becomes a more realistic option. Here, the current understanding of cardiac fibrosis and the great potential of tissue engineering are presented. Approaches using hydrogel-based tissue engineered heart constructs are discussed to contemplate key challenges for modeling tissue engineered cardiac fibrosis and to provide a future outlook for preclinical and clinical applications. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Elliptical Local Vessel Density: a Fast and Robust Quality Metric for Fundus Images

    Energy Technology Data Exchange (ETDEWEB)

    Giancardo, Luca [ORNL; Chaum, Edward [ORNL; Karnowski, Thomas Paul [ORNL; Meriaudeau, Fabrice [ORNL; Tobin Jr, Kenneth William [ORNL; Abramoff, M.D. [University of Iowa

    2008-01-01

    A great effort of the research community is geared towards the creation of an automatic screening system able to promptly detect diabetic retinopathy with the use of fundus cameras. In addition, there are some documented approaches to the problem of automatically judging the image quality. We propose a new set of features independent of Field of View or resolution to describe the morphology of the patient's vessels. Our initial results suggest that they can be used to estimate the image quality in a time one order of magnitude shorter respect to previous techniques.

  13. [Mechanism of "treating heart and brain with same methods" based on data science].

    Science.gov (United States)

    Chen, Di; Tang, Shi-huan; Lu, Peng; Yang, Hong-jun

    2015-11-01

    The traditional Chinese medicine (TCM) theory of "treating heart and brain diseases with same methods (Nao Xin Tong Zhi: NXTZ)" has great significance to the treatment of cardiovascular and cerebrovascular diseases. It has been proven effective by a great deal of clinical researches. However, the underlying mechanism for this theory is still unclear. To provide insights into the potential mechanism of "NXTZ", this study attempts to deeply investigate the mechanism from two representative cardiovascular and cerebrovascular diseases, coronary heart disease (CHD) and cerebral apoplexy. First, various data resources were integrated to obtain different types of biomedical entities including drugs, targets, pathways and diseases. Then, three different approaches including text mining, biological network and enrichment analysis were utilized to recognize the potential common features between CHD and cerebral apoplexy, and the corresponding functions of drugs which could treat both diseases, thus unveiling the mechanism of NXTZ.

  14. Nuclear reactor pressure vessel-specific flaw distribution development

    International Nuclear Information System (INIS)

    Rosinski, S.T.

    1992-01-01

    Vessel integrity predictions performed through fracture mechanics analysis of a pressurized thermal shock event have been shown to be significantly sensitive to the overall flaw distribution input. It has also been shown that modem vessel in-service inspection (ISI) results can be used for development of vessel flaw distribution(s) that are more representative of US vessels. This paper describes the development and application of a methodology to analyze ISI data for the purpose of flaw distribution determination. The resultant methodology considers detection reliability, flaw sizing accuracy, and flaw detection threshold in its application. Application of the methodology was then demonstrated using four recently acquired US PWR vessel inspection data sets. Throughout the program, new insight was obtained into several key inspection performance and vessel integrity prediction practice issues that will impact future vessel integrity evaluation. For example, the potential application of a vessel-specific flaw distribution now provides at least one method by which a vessel-specific reference flaw size applicable to pressure-temperature limit curves determination can be estimated. This paper will discuss the development and application of the methodology and the impact to future vessel integrity analyses

  15. Integral experiments on in-vessel coolability and vessel creep: results and analysis of the FOREVER-C1 test

    Energy Technology Data Exchange (ETDEWEB)

    Sehgal, B.R.; Nourgaliev, R.R.; Dinh, T.N.; Karbojian, A. [Division of Nuclear Power Safety, Royal Institute of Technology, Drottning Kristinas Vaeg., Stockholm (Sweden)

    1999-07-01

    This paper describes the FOREVER (Failure Of REactor VEssel Retention) experimental program, which is currently underway at the Division of Nuclear Power Safety, Royal Institute of Technology (RIT/NPS). The objectives of the FOREVER experiments are to obtain data and develop validated models (i) on the melt coolability process inside the vessel, in the presence of water (in particular, on the efficacy of the postulated gap cooling to preclude vessel failure); and (ii) on the lower head failure due to the creep process in the absence of water inside and/or outside the lower head. The paper presents the experimental results and analysis of the first FOREVER-C1 test. During this experiment, the 1/10th scale pressure vessel, heated to about 900degC and pressurized to 26 bars, was subjected to creep deformation in a non-stop 24-hours test. The vessel wall displacement data clearly shows different stages of the vessel deformation due to thermal expansion, elastic, plastic and creep processes. The maximum displacement was observed at the lowermost region of the vessel lower plenum. Information on the FOREVER-C1 measured thermal characteristics and analysis of the observed thermal and structural behavior is presented. The coupled nature of thermal and mechanical processes, as well as the effect of other system conditions (such as depressurization) on the melt pool and vessel temperature responses are analyzed. (author)

  16. Morphological aspects of myocardial bridges.

    Science.gov (United States)

    Lujinović, Almira; Kulenović, Amela; Kapur, Eldan; Gojak, Refet

    2013-11-01

    Although some myocardial bridges can be asymptomatic, their presence often causes coronary disease either through direct compression of the "tunnel" segment or through stimulation and accelerated development of atherosclerosis in the segment proximally to the myocardial bridge. The studied material contained 30 human hearts received from the Department of Anatomy. The hearts were preserved 3 to 5 days in 10% formalin solution. Thereafter, the fatty tissue was removed and arterial blood vessels prepared by careful dissection with special reference to the presence of the myocardial bridges. Length and thickness of the bridges were measured by the precise electronic caliper. The angle between the myocardial bridge fibre axis and other axis of the crossed blood vessel was measured by a goniometer. The presence of the bridges was confirmed in 53.33% of the researched material, most frequently (43.33%) above the anterior interventricular branch. The mean length of the bridges was 14.64 ± 9.03 mm and the mean thickness was 1.23 ± 1.32 mm. Myocardial bridge fibres pass over the descending blood vessel at the angle of 10-90 degrees. The results obtained on a limited sample suggest that the muscular index of myocardial bridge is the highest for bridges located on RIA, but that the difference is not significant in relation to bridges located on other branches. The results obtained suggest that bridges located on other branches, not only those on RIA, could have a great contractive power and, consequently, a great compressive force, which would be exerted on the wall of a crossed blood vessel.

  17. Optimizing the recovery efficiency of Finnish oil combating vessels in the Gulf of Finland using Bayesian Networks.

    Science.gov (United States)

    Lehikoinen, Annukka; Luoma, Emilia; Mäntyniemi, Samu; Kuikka, Sakari

    2013-02-19

    Oil transport has greatly increased in the Gulf of Finland over the years, and risks of an oil accident occurring have risen. Thus, an effective oil combating strategy is needed. We developed a Bayesian Network (BN) to examine the recovery efficiency and optimal disposition of the Finnish oil combating vessels in the Gulf of Finland (GoF), Eastern Baltic Sea. Four alternative home harbors, five accident points, and ten oil combating vessels were included in the model to find the optimal disposition policy that would maximize the recovery efficiency. With this composition, the placement of the oil combating vessels seems not to have a significant effect on the recovery efficiency. The process seems to be strongly controlled by certain random factors independent of human action, e.g. wave height and stranding time of the oil. Therefore, the success of oil combating is rather uncertain, so it is also important to develop activities that aim for preventing accidents. We found that the model developed is suitable for this type of multidecision optimization. The methodology, results, and practices are further discussed.

  18. Resurgery for recurrent heart valve diseases

    Directory of Open Access Journals (Sweden)

    Chong-lei REN

    2017-02-01

    Full Text Available Objective To summarize the experience with resurgery for recurrent valvular heart diseases. Methods From June 2004 to June 2015, 28 patients (15 males and 13 females with ages ranging from 44 to 67 years (55.6±6.5 years with recurrent heart valve disease underwent resurgery. The reasons for resurgery included perivalvular leakage (7 cases, bioprosthetic valve decline (6 cases in mitral valve and 3 in tricuspid valve, mechanical prostheses dysfunction (2cases, infective endocarditis after valve replacement (2 cases, restenosis of repaired native valve (1 case, and severe tricuspid insufficiency after left-side valve surgery (7 cases. Resurgery included mitral valve replacement in 18 patients and tricuspid valve replacement in 10. All the patients underwent third or fourth or even fifth cardiac surgery for valve replacement. Results There were 2 hospital deaths with a mortality of 7.1% (2/28. The main causes of early-stage deaths were low cardiac output syndrome. The main postoperative complications were respiratory failure in 3, low cardiac output syndrome in 2, reexploration for bleeding in 2 and serious infectious shock in 1. All the patients were found with the great improvement in heart function and the re-implanted prostheses worked well during follow-up. Conclusions Although resurgery for recurrent heart valve disease poses a continuing challenge to cardiac surgeon, it could be performed with the satisfactory results. The keys to a successful cardiac resurgery include appropriate operational timing, refined surgical technique and reasonable perioperative managements. DOI: 10.11855/j.issn.0577-7402.2017.01.11

  19. Pressure vessel integrity 1991

    International Nuclear Information System (INIS)

    Bhandari, S.; Doney, R.O.; McDonald, M.S.; Jones, D.P.; Wilson, W.K.; Pennell, W.E.

    1991-01-01

    This volume contains papers relating to the structural integrity assessment of pressure vessels and piping, with special emphasis on nuclear industry applications. The papers were prepared for technical sessions developed under the sponsorship of the ASME Pressure Vessels and Piping Division Committees for Codes and Standards, Computer Technology, Design and Analysis, and Materials Fabrication. They were presented at the 1991 Pressure Vessels and Piping Division Conference in San Diego, California, June 23-27. The primary objective of the sponsoring organization is to provide a forum for the dissemination and discussion of information on development and application of technology for the structural integrity assessment of pressure vessels and piping. This publication includes contributions from authors from Australia, France, Japan, Sweden, Switzerland, the United Kingdom, and the United States. The papers here are organized in six sections, each with a particular emphasis as indicated in the following section titles: Fracture Technology Status and Application Experience; Crack Initiation, Propagation and Arrest; Ductile Tearing; Constraint, Stress State, and Local-Brittle-Zones Effects; Computational Techniques for Fracture and Corrosion Fatigue; and Codes and Standards for Fatigue, Fracture and Erosion/Corrosion

  20. Contracts used for the charter or lease of pleasure vessels in pleasure navigation : an Italian perspective

    Directory of Open Access Journals (Sweden)

    Elena Orrù

    2018-02-01

    Full Text Available The Italian Navigation Code has transposed the practices developed at international level, in particular in international contracts for the ‘’locazione’’ and ‘’noleggio’’ of ships, distinguishing between the ship lease, from the one side, and the charter, from the other. The latter, in particular, consists of voyage charter and time charter. However, the Italian discipline differs in several respects from the contract types developed at international level. As for pleasure vessels, a specific regime lacked until the Law of 11 February 1971, No 50. The great development of this sector (which was previously considered limited to the use of pleasure vessels only for personal purposes, in particular of the entrepreneurial use of these vessels, furthered the draft and enactment, in 2005, of the Pleasure Navigation Code (Law of 18 July 2005, No 171, providing for a more comprehensive regime, however still not covering all the issues and aspects of pleasure navigation. The Code provides for a special regime of the contracts for the lease and charter of pleasure vessels: this article provides a review of the regime of these contracts provided by the Italian Pleasure Navigation Code, with regard also to its relationship with the Navigation Code and the Civil Code. The Code’s provisions are also examined with reference to standard contracts developed at the international level.

  1. Rapid analysis of vessel elements (RAVE: a tool for studying physiologic, pathologic and tumor angiogenesis.

    Directory of Open Access Journals (Sweden)

    Marc E Seaman

    Full Text Available Quantification of microvascular network structure is important in a myriad of emerging research fields including microvessel remodeling in response to ischemia and drug therapy, tumor angiogenesis, and retinopathy. To mitigate analyst-specific variation in measurements and to ensure that measurements represent actual changes in vessel network structure and morphology, a reliable and automatic tool for quantifying microvascular network architecture is needed. Moreover, an analysis tool capable of acquiring and processing large data sets will facilitate advanced computational analysis and simulation of microvascular growth and remodeling processes and enable more high throughput discovery. To this end, we have produced an automatic and rapid vessel detection and quantification system using a MATLAB graphical user interface (GUI that vastly reduces time spent on analysis and greatly increases repeatability. Analysis yields numerical measures of vessel volume fraction, vessel length density, fractal dimension (a measure of tortuosity, and radii of murine vascular networks. Because our GUI is open sourced to all, it can be easily modified to measure parameters such as percent coverage of non-endothelial cells, number of loops in a vascular bed, amount of perfusion and two-dimensional branch angle. Importantly, the GUI is compatible with standard fluorescent staining and imaging protocols, but also has utility analyzing brightfield vascular images, obtained, for example, in dorsal skinfold chambers. A manually measured image can be typically completed in 20 minutes to 1 hour. In stark comparison, using our GUI, image analysis time is reduced to around 1 minute. This drastic reduction in analysis time coupled with increased repeatability makes this tool valuable for all vessel research especially those requiring rapid and reproducible results, such as anti-angiogenic drug screening.

  2. In vitro evaluation of physiological spiral anastomoses for the arterial switch operation in simple transposition of the great arteries: a first step towards a surgical alternative?

    Science.gov (United States)

    Sievers, Hans-Hinrich; Scharfschwerdt, Michael; Putman, Léon M

    2015-08-01

    The currently most frequently used technique for the arterial switch operation (ASO) in simple transposition of the great arteries (TGA) includes the transposition of the pulmonary artery anterior to the ascending aorta. This arterial arrangement is less anatomical, and although the initial results are excellent, some long-term data are indicating a certain risk of morbidity, encouraging the search for more physiological techniques. As a first step, we studied the feasibility of anatomical spiral anastomoses of the great vessels in vitro. A TGA model was constructed to simulate the different spatial positions of the great arteries followed by ASO with physiological spiral connections of the great arteries. It was possible to perform a physiological spiral connection of the great arteries without tension or torsion when the roots of the great vessels were arranged anterior-posterior and with up to 35° rotation of the aortic root to the right around the pulmonary root. With further rotation of the aorta, patch plasties were required for pulmonary artery elongation. The maximal width of the patch was 5 mm. In this TGA model, it was possible to perform tension- and torsion-free arterial anastomoses for ASO without artificial material, when the aortic root was positioned from 0° up to 35° to the right of the pulmonary root. Evaluation of coronary transfer is the next step. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  3. Test of 6-in.-thick pressure vessels. Series 3: intermediate test vessel V-7A under sustained loading

    International Nuclear Information System (INIS)

    Bryan, R.H.; Cate, T.M.; Holz, P.P.; King, T.A.; Merkle, J.G.; Robinson, G.C.; Smith, G.C.; Smith, J.E.; Whitman, G.D.

    1978-01-01

    HSST intermediate test vessel V-7 was repaired after being tested hydrostatically to leakage and was retested pneumatically as vessel V-7A. Except for the method of applying the load, the conditions in both tests were nearly identical. In each case, a sharp outside surface flaw 547 mm long (18 in.) by about 135 mm deep (5.3 in.) was prepared in the 152-mm-thick (6-in.) test cylinder of A533, grade B, class 1 steel. The inside surface of vessel V-7A was sealed in the region of the flaw by a thin metal patch so that pressure could be sustained after rupture. Vessel V-7A failed by rupture of the flaw ligament without burst, as expected. Rupture occurred at 144.3 MPa (20.92 ksi), after which pressure was sustained for 30 min without any indication of instability. The rupture pressure of vessel V-7A was about 2 percent less than that of vessel V-7

  4. Cyanotic congenital heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Yeon, Kyung Mo; Yoo, Shi Joon; Han, Man Chung; Hong, Chang Yee; Lee, Yung Kyoon [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1979-12-15

    Authors analyzed 265 cases of cyanotic congenital heart disease in which cardiac catheterization and angiocardiography were done at the Department of Radiology, Seoul National University Hospital between April 1973 and August 1979. The results are as follows; 1. Among 265 cases, 178 patients were male and 87 patients were female. 240 patients were below the age of 20 and none was over 35 year. 2. The incidence of individual lesions are as follows: tetralogy of Fallot-176; double outlet right ventricle-20; pentalogy-12; trilogy-11; corrected transposition of great arteries-10; complete transposition of great arteries-8; pulmonary atresia-7; single ventricle-6; Ebstein's anomaly-5; total anomalous pulmonary venous return-4; tricuspid atresia-3; double outlet left ventricle-1; truncus arteriosus-1; hypoplastic left ventricle-1. 3. Fallot's teralogy, pentalogy and trilogy were characteristic in their simple chest and angiocardiographic manifestations, but in a few cases of tetralogy and pentalogy it was difficult to differentiate them from double outlet right ventricle or pulmonary atresia. 4. In double outlet right ventricle and transposition of great arteries which are the pathologic spectrum resulting from abnormal conal growth, differential points were ventricular and great arterial loop patterns and their connections but it was very difficult to differentiate them from each other by single injection into one ventricle alone. 5. Ebstein's anomaly and total anomalous pulmonary venous return were so characteristic in angiocardiography was done ventriculography alone. 6. In 7 cases with double outlet right ventricle and transposition of great arteries, selective biventriculography was done and more accurate diagnosis could be made, which was quite difficult with one ventriculography alone. In 31 cases, cineangiocardiography was done and it gave more accurate information about the type and degree of pulmonary stenosis and overriding of aorta, the origin

  5. Change of Diurnal Heart Rate Patterns During Pregnancy and Lactation in Dogs (Canis familiaris

    Directory of Open Access Journals (Sweden)

    Häggström J

    2003-09-01

    Full Text Available Pregnancy and lactation involve great demands on the cardiovascular system. The purpose of this study was to investigate how the heart rate and diurnal heart rate pattern change when dogs become pregnant or lactate. Five clinically healthy female beagle dogs were mated, and delivered three to seven healthy puppies. The heart rate was investigated with 24-h ECG (Holter once during anoestrus, at 3, 5, 7 and 9 weeks of pregnancy, and at week 4 postpartum (lactation. However, at 9 weeks, the ECG could not be recorded for the fully 24 h in 4 of 5 dogs, because labour started and the dogs then appeared disturbed by the recordings. The results at this date are not included in the statistical comparison. The heart rate increased progressively during pregnancy and was still elevated at 4 weeks of lactation. During late pregnancy the difference in heart rates between daytime and nighttime became smaller, but the heart rate was significantly higher in daytime in all periods. In conclusion, the increased heart rates during pregnancy and lactation reflect increased demands on the cardiovascular system and may be important to consider in clinical practice.

  6. Arteriosclerotic changes in the myocardium, lung, and kidney in dogs with chronic congestive heart failure and myxomatous mitral valve disease

    DEFF Research Database (Denmark)

    Falk, Bo Torkel; Jönsson, Lennart; Olsen, Lisbeth Høier

    2006-01-01

    Background: The occurrence of small vessel arteriosclerosis in the myocardium, kidney, and lung in dogs with naturally occurring myxomatous mitral valve disease has not been previously investigated systematically. Methods: Twenty-one dogs with naturally occurring congestive heart failure and 21 age......-matched, sex-matched, and weight-matched control dogs underwent extensive pathological and histopathological examination. Morphometry and scoring of tissue sections were used to measure arterial narrowing and fibrosis in the myocardium, kidney, and lung; and intimal thickness and plaque formation in the aorta...... and pulmonary artery. Results: Dogs with congestive heart failure had significantly more arterial narrowing in the left ventricle (Pdogs. However...

  7. Graywater Discharges from Vessels

    Science.gov (United States)

    2011-11-01

    metals (e.g., cadmium, chromium, lead, copper , zinc, silver, nickel, and mercury), solids, and nutrients (USEPA, 2008b; USEPA 2010). Wastewater from... flotation ), and disinfection (using ultraviolet light) as compared to traditional Type II MSDs that use either simple maceration and chlorination, or...Coliform Naval Vessels Oceanographic Vessels Small Cruise Ships 25a Vendor 2 Hamann AG Biological Treatment with Dissolved Air Flotation and

  8. The Great Recession was not so Great

    NARCIS (Netherlands)

    van Ours, J.C.

    2015-01-01

    The Great Recession is characterized by a GDP-decline that was unprecedented in the past decades. This paper discusses the implications of the Great Recession analyzing labor market data from 20 OECD countries. Comparing the Great Recession with the 1980s recession it is concluded that there is a

  9. Reactor vessel decommissioning project. Final report

    International Nuclear Information System (INIS)

    Schoonen, D.H.

    1984-09-01

    This report describes a reactor vessel decommissioning project; it documents and explains the project objectives, scope, performance results, and sodium removal process. The project was successfully completed in FY-1983, within budget and without significant problems or adverse impact on the environment. Waste generated by the operation included the reactor vessel, drained sodium, and liquid, solid, and gaseous wastes which were significantly less than project estimates. Personnel radiation exposures were minimized, such that the project total was one-half the predicted exposure level. Except for the sodium removed, the material remaining in the reactor vessel is essentially the same as when the vessel arrived for processing

  10. Electrical discharge machining for vessel sample removal

    International Nuclear Information System (INIS)

    Litka, T.J.

    1993-01-01

    Due to aging-related problems or essential metallurgy information (plant-life extension or decommissioning) of nuclear plants, sample removal from vessels may be required as part of an examination. Vessel or cladding samples with cracks may be removed to determine the cause of cracking. Vessel weld samples may be removed to determine the weld metallurgy. In all cases, an engineering analysis must be done prior to sample removal to determine the vessel's integrity upon sample removal. Electrical discharge machining (EDM) is being used for in-vessel nuclear power plant vessel sampling. Machining operations in reactor coolant system (RCS) components must be accomplished while collecting machining chips that could cause damage if they become part of the flow stream. The debris from EDM is a fine talclike particulate (no chips), which can be collected by flushing and filtration

  11. Heart Failure

    Science.gov (United States)

    Heart failure is a condition in which the heart can't pump enough blood to meet the body's needs. Heart failure does not mean that your heart has stopped ... and shortness of breath Common causes of heart failure are coronary artery disease, high blood pressure and ...

  12. Nuclear power plant pressure vessels. Inservice inspections

    International Nuclear Information System (INIS)

    1995-01-01

    The requirements for the planning and reporting of inservice inspections of nuclear power plant pressure vessels are presented. The guide specifically applies to inservice inspections of Safety class 1 and 2 nuclear power plant pressure vessels, piping, pumps and valves plus their supports and reactor pressure vessel internals by non- destructive examination methods (NDE). Inservice inspections according to the Pressure Vessel Degree (549/73) are discussed separately in the guide YVL 3.0. (4 refs.)

  13. Offshore wind transport and installation vessel

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    The initial objective of the project was to complete a feasibility study to determine the viability of an innovative transportation vessel to be deployed in the installation of offshore wind farms. This included the feasibility of providing a stable-working platform that can be used in harsh offshore environments. A study of current installation contractors and their installation equipment was used to provide a preliminary specification for the installation vessel. A typical barge was selected and a number of hydrodynamic analyses were carried out in order to establish it's on course and operational stability. The analysis proved the stability of the vessel during operation was critical and that in order to utilise the crane's full potential a stabilisation system must be employed. The main aim of the work to date was to establish whether it was feasible to use a stabilisation system on the installation vessel. The spud leg FEED study established that it was feasible to use spud legs to stabilise the vessel. In order to achieve the degree of stability required it is necessary to lift the vessel completely out of the water. This was not the original aim of the study but due to the external loads on the hull it was the only viable option. Lifting the vessel out of the water results in the legs and leg casings becoming very large. This has a number of consequences for the final design. Due to large loads on the legs spud cans must be used to avoid bottom penetration, the spud cans increase the draft of the vessel by 2m. The large loads require larger winches and more reeving to be used, this results in larger pumps and motors, all of which have to be housed. The stabilisation system has been proved to be feasible for a large installation vessel, the cost and physical size are however more excessive than first anticipated. (Author)

  14. 46 CFR 15.405 - Familiarity with vessel characteristics.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Familiarity with vessel characteristics. 15.405 Section... MANNING REQUIREMENTS Manning Requirements; All Vessels § 15.405 Familiarity with vessel characteristics. Each credentialed individual must become familiar with the relevant characteristics of the vessel on...

  15. Heart rate variability analysis in acute poisoning by cholinesterase inhibitors

    OpenAIRE

    JEONG, JINWOO; KIM, YONGIN

    2017-01-01

    Heart rate variability (HRV) has been associated with a variety of clinical situations. However, few studies have examined the association between HRV and acute poisoning. Organophosphate (OP) and carbamate inhibit esterase enzymes, particularly acetylcholinesterase, resulting in an accumulation of acetylcholine and thereby promoting excessive activation of corresponding receptors. Because diagnosis and treatment of OP and carbamate poisoning greatly depend on...

  16. Heart MRI

    Science.gov (United States)

    Magnetic resonance imaging - cardiac; Magnetic resonance imaging - heart; Nuclear magnetic resonance - cardiac; NMR - cardiac; MRI of the heart; Cardiomyopathy - MRI; Heart failure - MRI; Congenital heart disease - MRI

  17. Estimation of center line and diameter of brain blood vessel using three-dimensional blood vessel matching method with head three-dimensional CTA image

    International Nuclear Information System (INIS)

    Maekawa, Masashi; Shinohara, Toshihiro; Nakayama, Masato; Nakasako, Noboru

    2010-01-01

    To support and automate the brain blood vessel disease diagnosis, a novel method to obtain the center line and the diameter of a blood vessel is proposed with a three-dimensional head computed tomographic angiography (CTA) image. Although the line thinning processing with distance transform or gray information is generally used to obtain the blood vessel center line, this method is not essentially one to obtain the center line and tends to yield extra lines depending on CTA images. In this study, the center line of the blood vessel is obtained by tracing the vessel. The blood vessel is traced by sequentially estimating the center point and direction of the blood vessel. The center point and direction of the blood vessel are estimated by taking the correlation between the blood vessel and a solid model of the blood vessel that is designed by considering noise influence. In addition, the vessel diameter is also estimated by correlating the blood vessel and the blood vessel model of which the diameter is variable. The validity of the proposed method is confirmed by experimentally applied the proposed method to an actual three-dimensional head CTA image. (author)

  18. Design of the ITER vacuum vessel

    International Nuclear Information System (INIS)

    Ioki, K.; Johnson, G.; Shimizu, K.; Williamson, D.

    1995-01-01

    The ITER vacuum vessel is a major safety barrier and must support electromagnetic loads during plasma disruptions and vertical displacement events (VDE) and withstand plausible accidents without losing confinement.The vacuum vessel has a double wall structure to provide structural and electrical continuity in the toroidal direction. The inner and outer shells and poloidal stiffening ribs between them are joined by welding, which gives the vessel the required mechanical strength. The space between the shells will be filled with steel balls and plate inserts to provide additional nuclear shielding. Water flowing in this space is required to remove nuclear heat deposition, which is 0.2-2.5% of the total fusion power. The minor and major radii of the tokamak are 3.9 m and 13 m respectively, and the overall height is 15 m. The total thickness of the vessel wall structure is 0.4-0.7 m.The inboard and outboard blanket segments are supported from the vacuum vessel. The support structure is required to withstand a large total vertical force of 200-300 MN due to VDE and to allow for differential thermal expansion.The first candidate for the vacuum vessel material is Inconel 625, due to its higher electric resistivity and higher yield strength, even at high temperatures. Type 316 stainless steel is also considered a vacuum vessel material candidate, owing to its large database and because it is supported by more conventional fabrication technology. (orig.)

  19. No evidence for an open vessel effect in centrifuge-based vulnerability curves of a long-vesselled liana (Vitis vinifera).

    Science.gov (United States)

    Jacobsen, Anna L; Pratt, R Brandon

    2012-06-01

    Vulnerability to cavitation curves are used to estimate xylem cavitation resistance and can be constructed using multiple techniques. It was recently suggested that a technique that relies on centrifugal force to generate negative xylem pressures may be susceptible to an open vessel artifact in long-vesselled species. Here, we used custom centrifuge rotors to measure different sample lengths of 1-yr-old stems of grapevine to examine the influence of open vessels on vulnerability curves, thus testing the hypothesized open vessel artifact. These curves were compared with a dehydration-based vulnerability curve. Although samples differed significantly in the number of open vessels, there was no difference in the vulnerability to cavitation measured on 0.14- and 0.271-m-long samples of Vitis vinifera. Dehydration and centrifuge-based curves showed a similar pattern of declining xylem-specific hydraulic conductivity (K(s)) with declining water potential. The percentage loss in hydraulic conductivity (PLC) differed between dehydration and centrifuge curves and it was determined that grapevine is susceptible to errors in estimating maximum K(s) during dehydration because of the development of vessel blockages. Our results from a long-vesselled liana do not support the open vessel artifact hypothesis. © 2012 The Authors. New Phytologist © 2012 New Phytologist Trust.

  20. Test of 6-inch-thick pressure vessels. Series 2. Intermediate test vessels V-3, V-4, and V-6

    International Nuclear Information System (INIS)

    Bryan, R.H.; Merkle, J.G.; Raftenberg, M.N.; Robinson, G.C.; Smith, J.E.

    1975-11-01

    The second series of intermediate vessel tests were crack initiation fracture tests of 6-in.-thick 39-in.-OD steel vessels with sharp surface flaws approximately 2 1 / 2 in. deep by 8 in. long in the longitudinal weld seams of the test cylinders. Fracture was initiated by means of hydraulic pressurization. One vessel was tested at each of three temperatures: 75, 130, and 190 0 F. Pretest analyses were made to predict the failure pressures and strains. Fracture toughness data obtained by equivalent-energy analysis of precracked Charpy-V tests and compact-tension specimen tests were used in the fracture analyses. The vessels behaved generally as had been expected. Posttest fracture analyses were also performed for each vessel. Detailed discussions of the fracture analysis methods developed in support of the vessel tests described are included. 34 references

  1. PWR vessel inspection performance improvements

    International Nuclear Information System (INIS)

    Blair Fairbrother, D.; Bodson, Francis

    1998-01-01

    A compact robot for ultrasonic inspection of reactor vessels has been developed that reduces setup logistics and schedule time for mandatory code inspections. Rather than installing a large structure to access the entire weld inspection area from its flange attachment, the compact robot examines welds in overlapping patches from a suction cup anchor to the shell wall. The compact robot size allows two robots to be operated in the vessel simultaneously. This significantly reduces the time required to complete the inspection. Experience to date indicates that time for vessel examinations can be reduced to fewer than four days. (author)

  2. TPX vacuum vessel transient thermal and stress conditions

    International Nuclear Information System (INIS)

    Feldshteyn, Y.; Dinkevich, S.; Feng, T.; Majumder, D.

    1995-01-01

    The TPX vacuum vessel provides the vacuum boundary for the plasma and the mechanical support for the internal components. Another function of the vacuum vessel is to contain neutron shielding water in the double wall space during normal operation. This double wall space serves as a heat reservoir for the entire vacuum vessel during bakeout. The vacuum vessel and the internal components are subjected to thermal stresses induced by a nonuniform temperature distribution within the structure during bakeout. A successful Conceptual Design Review in March 1993 has established superheated steam as the heating source of the vacuum vessel. A transient bakeout mode of the vacuum vessel and in-vessel components has been analyzed to evaluate transient period duration, proper temperature level, actual thermal stresses and performance of the steam equipment. Thermally, the vacuum vessel structure may be considered as an adiabatic system because it is perfectly insulated by the strong surrounding vacuum and multiple layers of superinsulation. Important aspects of the analysis are described herein

  3. In service inspection of SUPERPHENIX 1 vessels: MIR

    International Nuclear Information System (INIS)

    Asty, M.; Viard, J.; Lerat, B.; Saglio, R.

    1985-01-01

    Although no in-service inspection constraints were imposed on the Phenix vessels, the Safety Authorities asked that the design of SUPERPHENIX 1 makes it possible to monitor throughout the lifetime of the reactor, surface and internal defects on the main vessel. A pool design and the presence of heat baffles inside the main vessel make access from the inside of the vessel impossible. Thus, an inspection can only be performed from the outside of the main vessel: the distance between the walls of the main and safety vessels is such that an inspection device can be introduced into the corresponding space. As the design of the reactor precludes radiographic inspection, the method which was selected for monitoring internal defects in the main vessel is ultrasonics. However, the anisotropic structure of austenitic stainless steel welds limits the performance of this technique. The authors present the in-service inspection device, MIR, which has been specially developed for the visual and ultrasonic examination of SUPERPHENIX 1 vessels

  4. Final report for the 2nd Ex-Vessel Neutron Dosimetry Installations and Evaluations for Yonggwang Unit 2 Reactor Pressure Vessel

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Byoung Chul; Yoo, Choon Sung; Lee, Sam Lai; Gong, Un Sik; Choi, Kwon Jae; Chung, Kyoung Ki; Kim, Kwan Hyun; Chang, Jong Hwa; Ha, Jea Ju

    2008-01-15

    This report describes a neutron fluence assessment performed for the Yonggwang Unit 2 pressure vessel beltline region based on the guidance specified in Regulatory Guide 1.190. In this assessment, maximum fast neutron exposures expressed in terms of fast neutron fluence (E>1 MeV) and iron atom displacements (dpa) were established for the beltline region of the pressure vessel. During Cycle 16 of reactor operation, an Ex-Vessel Neutron Dosimetry Program was instituted at Yonggwang Unit 2 to provide continuous monitoring of the beltline region of the reactor vessel. The use of the Ex-Vessel Neutron Dosimetry Program coupled with available surveillance capsule measurements provides a plant specific data base that enables the evaluation of the vessel exposure and the uncertainty associated with that exposure over the service life of the unit. Ex-Vessel Neutron Dosimetry has been evaluated at the conclusion of Cycle 16.

  5. Final report for the 1st ex-vessel neutron dosimetry installations and evaluations for Kori unit 2 reactor pressure vessel

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Byoung Chul; Yoo, Choon Sung; Lee, Sam Lai; Chang, Kee Ok; Gong, Un Sik; Choi, Kwon Jae; Chang, Jong Hwa; Lim, Nam Jin; Hong, Joon Wha; Cheon, Byeong Jin

    2006-11-15

    This report describes a neutron fluence assessment performed for the Kori unit 2 pressure vessel belt line region based on the guidance specified in regulatory guide 1.190. In this assessment, maximum fast neutron exposures expressed in terms of fast neutron fluence (E>1 MeV) and iron atom displacements (dpa) were established for the belt line region of the pressure vessel. During cycle 20 of reactor operation, an ex-vessel neutron dosimetry program was instituted at Kori unit 2 to provide continuous monitoring of the belt line region of the reactor vessel. The use of the ex-vessel neutron dosimetry program coupled with available surveillance capsule measurements provides a plant specific data base that enables the evaluation of the vessel exposure and the uncertainty associated with that exposure over the service life of the unit. Ex-vessel neutron dosimetry has been evaluated at the conclusion of cycle 20.

  6. Final Report of the 2nd Ex-Vessel Neutron Dosimetry Installation And Evaluations for Yonggwang Unit 1 Reactor Pressure Vessel

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Byoung Chul; Yoo, Choon Sung; Lee, Sam Lai; Chang, Kee Ok; Gong, Un Sik; Choi, Kwon Jae; Chang, Jong Hwa; Li, Nam Jin; Hong, Joon Wha

    2007-01-15

    This report describes a neutron fluence assessment performed for the Yonggwang Unit 1 pressure vessel belt line region based on the guidance specified in Regulatory Guide 1.190. In this assessment, maximum fast neutron exposures expressed in terms of fast neutron fluence (E>1 MeV) and iron atom displacements (dpa) were established for the belt line region of the pressure vessel. During Cycle 16 of reactor operation, 2nd Ex-Vessel Neutron Dosimetry Program was instituted at Yonggwang Unit 1 to provide continuous monitoring of the belt line region of the reactor vessel. The use of the Ex-Vessel Neutron Dosimetry Program coupled with available surveillance capsule measurements provides a plant specific data base that enables the evaluation of the vessel exposure and the uncertainty associated with that exposure over the service life of the unit. Ex-Vessel Neutron Dosimetry has been evaluated at the conclusion of Cycle 16.

  7. Final Report of the 2nd Ex-Vessel Neutron Dosimetry Installation And Evaluations for Yonggwang Unit 1 Reactor Pressure Vessel

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Byoung Chul; Yoo, Choon Sung; Lee, Sam Lai; Gong, Un Sik; Choi, Kwon Jae; Chung, Kyoung Ki; Kim, Kwan Hyun; Chang, Jong Hwa; Ha, Jea Ju

    2008-01-15

    This report describes a neutron fluence assessment performed for the Kori Unit 2 pressure vessel belt line region based on the guidance specified in Regulatory Guide 1.190. In this assessment, maximum fast neutron exposures expressed in terms of fast neutron fluence (E>1 MeV) and iron atom displacements (dpa) were established for the belt line region of the pressure vessel. During Cycle 21 of reactor operation, an Ex-Vessel Neutron Dosimetry Program was instituted at Kori Unit 2 to provide continuous monitoring of the belt line region of the reactor vessel. The use of the Ex-Vessel Neutron Dosimetry Program coupled with available surveillance capsule measurements provides a plant specific data base that enables the evaluation of the vessel exposure and the uncertainty associated with that exposure over the service life of the unit. Ex-Vessel Neutron Dosimetry has been evaluated at the conclusion of Cycle 21.

  8. Final report for the 1st ex-vessel neutron dosimetry installation and evaluations for Kori unit 4 reactor pressure vessel

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Byoung Chul; Yoo, Choon Sung; Lee, Sam Lai; Chang, Kee Ok; Gong, Un Sik; Choi, Kwon Jae; Chang, Jong Hwa; Lim, Nam Jin; Hong, Joon Wha; Cheon, Byeong Jin

    2006-11-15

    This report describes a neutron fluence assessment performed for the Kori unit 4 pressure vessel belt line region based on the guidance specified in regulatory guide 1.190. In this assessment, maximum fast neutron exposures expressed in terms of fast neutron fluence (E>1 MeV) and iron atom displacements (dpa) were established for the belt line region of the pressure vessel. During cycle 16 of reactor operation, an ex-vessel neutron dosimetry program was instituted at Kori unit 4 to provide continuous monitoring of the belt line region of the reactor vessel. The use of the ex-vessel neutron dosimetry program coupled with available surveillance capsule measurements provides a plant specific data base that enables the evaluation of the vessel exposure and the uncertainty associated with that exposure over the service life of the unit. Ex-vessel neutron dosimetry has been evaluated at the conclusion of cycle 16.

  9. Confinement Vessel Assay System: Calibration and Certification Report

    Energy Technology Data Exchange (ETDEWEB)

    Frame, Katherine C. [Los Alamos National Laboratory; Bourne, Mark M. [Los Alamos National Laboratory; Crooks, William J. [Los Alamos National Laboratory; Evans, Louise [Los Alamos National Laboratory; Gomez, Cipriano [Retired CMR-OPS: OPERATIONS; Mayo, Douglas R. [Los Alamos National Laboratory; Miko, David K. [Los Alamos National Laboratory; Salazar, William R. [Los Alamos National Laboratory; Stange, Sy [Los Alamos National Laboratory; Vigil, Georgiana M. [Los Alamos National Laboratory

    2012-07-17

    Los Alamos National Laboratory has a number of spherical confinement vessels (CVs) remaining from tests involving nuclear materials. These vessels have an inner diameter of 6 feet with 1 to 2 inch thick steel walls. The goal of the Confinement Vessel Disposition (CVD) project is to remove debris and reduce contamination inside the vessels. The Confinement Vessel Assay System (CVAS) was developed to measure the amount of SNM in CVs before and after cleanout. Prior to cleanout, the system will be used to perform a verification measurement of each vessel. After cleanout, the system will be used to perform safeguards-quality assays of {le} 100-g {sup 239}Pu equivalent in a vessel for safeguards termination. The system was calibrated in three different mass regions (low, medium, and high) to cover the entire plutonium mass range that will be assayed. The low mass calibration and medium mass calibration were verified for material positioned in the center of an empty vessel. The systematic uncertainty due to position bias was estimated using an MCNPX model to simulate the response of the system to material localized at various points along the inner surface of the vessel. The background component due to cosmic ray spallation was determined by performing measurements of an empty vessel and comparing to measurements in the same location with no vessel present. The CVAS has been tested and calibrated in preparation for verification and safeguards measurements of CVs before and after cleanout.

  10. Confinement Vessel Assay System: Calibration and Certification Report

    International Nuclear Information System (INIS)

    Frame, Katherine C.; Bourne, Mark M.; Crooks, William J.; Evans, Louise; Gomez, Cipriano; Mayo, Douglas R.; Miko, David K.; Salazar, William R.; Stange, Sy; Vigil, Georgiana M.

    2012-01-01

    Los Alamos National Laboratory has a number of spherical confinement vessels (CVs) remaining from tests involving nuclear materials. These vessels have an inner diameter of 6 feet with 1 to 2 inch thick steel walls. The goal of the Confinement Vessel Disposition (CVD) project is to remove debris and reduce contamination inside the vessels. The Confinement Vessel Assay System (CVAS) was developed to measure the amount of SNM in CVs before and after cleanout. Prior to cleanout, the system will be used to perform a verification measurement of each vessel. After cleanout, the system will be used to perform safeguards-quality assays of (le) 100-g 239 Pu equivalent in a vessel for safeguards termination. The system was calibrated in three different mass regions (low, medium, and high) to cover the entire plutonium mass range that will be assayed. The low mass calibration and medium mass calibration were verified for material positioned in the center of an empty vessel. The systematic uncertainty due to position bias was estimated using an MCNPX model to simulate the response of the system to material localized at various points along the inner surface of the vessel. The background component due to cosmic ray spallation was determined by performing measurements of an empty vessel and comparing to measurements in the same location with no vessel present. The CVAS has been tested and calibrated in preparation for verification and safeguards measurements of CVs before and after cleanout.

  11. Total lymphatic irradiation and bone marrow in human heart transplantation

    International Nuclear Information System (INIS)

    Kahn, D.R.; Hong, R.; Greenberg, A.J.; Gilbert, E.F.; Dacumos, G.C.; Dufek, J.H.

    1984-01-01

    Six patients, aged 36 to 59 years, had heart transplants for terminal myocardial disease using total lymphatic irradiation (TLI) and donor bone marrow in addition to conventional therapy. All patients were poor candidates for transplantation because of marked pulmonary hypertension, unacceptable tissue matching, or age. Two patients are living and well more than four years after the transplants. Two patients died of infection at six and seven weeks with normal hearts. One patient, whose preoperative pulmonary hypertension was too great for an orthotopic heart transplant, died at 10 days after such a procedure. The other patient died of chronic rejection seven months postoperatively. Donor-specific tolerance developed in 2 patients. TLI and donor bone marrow can produce specific tolerance to donor antigens and allow easy control of rejection, but infection is still a major problem. We describe a new technique of administering TLI with early reduction of prednisone that may help this problem

  12. Heart Health - Heart Disease: Symptoms, Diagnosis, Treatment

    Science.gov (United States)

    ... Bar Home Current Issue Past Issues Cover Story Heart Health Heart Disease: Symptoms, Diagnosis, Treatment Past Issues / Winter 2009 ... of this page please turn Javascript on. Most heart attacks happen when a clot in the coronary ...

  13. Diagnostic accuracy of dual-source CT coronary angiography in a population unselected for degree of coronary artery calcification and without heart rate modification

    International Nuclear Information System (INIS)

    Lin, C.-J.; Hsu, J.-C.; Lai, Y.-J.; Wang, K.-L.; Lee, J.-Y.; Li, A.-H.; Chu, S.-H.

    2010-01-01

    Aim: To assess the ability of coronary angiography performed using dual-source computed tomography (DSCT) to evaluate coronary artery disease (CAD) in a population with unselected heart rates and extensive coronary calcification. Materials and methods: Forty-four patients at intermediate to high risk for CAD underwent both DSCT coronary angiography and invasive coronary angiography (ICA) within 30 days. No beta blockers were administered prior to imaging. Image quality and quantitatively stenosis of all coronary segments with a diameter ≥1.5 mm were accessed. Patients were stratified according to mean heart rate (<70 versus ≥70 bpm) and heart rate variability (<10 versus ≥10 bpm). DSCT detection of coronary stenosis by segment, vessel, and patient characteristics were compared to the reference standard of ICA. Results: Diagnostic accuracy for all patients was high regarding sensitivity (97%), positive predictive value (PPV, 84.2%), and negative predictive value (NPV, 83.3%) but low regarding specificity (45.5%) with a moderate interobserver agreement (Kappa = 0.50). The accuracy for vessel-based diagnosis was high regarding sensitivity (96.6%), specificity (80.8%), PPV (80.3%), and NPV (96.7%). The segment-based diagnostic results revealed a moderate interobserver agreement for image quality and sensitivity, specificity, PPV and NPV for all segments of 66.9, 97.8, 90.8, and 89.9%, respectively. Conclusion: DSCT coronary angiography has high diagnostic accuracy in assessing CAD among patients at intermediate to high risk without using heart rate-modulating premedication. DSCT is not superior to ICA for diagnosis of calcified segments.

  14. Method for temporary shielding of reactor vessel internals

    International Nuclear Information System (INIS)

    Grimm, N.P.; Sejvar, J.

    1991-01-01

    This patent describes a method for shielding stored internals for reactor vessel annealing. It comprises removing nuclear fuel from the reactor vessel containment building; removing and storing upper and lower core internals under water in a refueling canal storage area; assembling a support structure in the refueling canal between the reactor vessel and the stored internals; introducing vertical shielding tanks individually through a hatch in the containment building and positioning each into the support structure; introducing horizontal shielding tanks individually through a hatch in the containment building and positioning each above the stored internals and vertical tanks; draining water from the refueling canal to the level of a flange of the reactor vessel; placing an annealing apparatus in the reactor vessel; pumping the remaining water from the reactor vessel; and annealing the reactor vessel

  15. Heart Health: The Heart Truth Campaign 2009

    Science.gov (United States)

    ... Bar Home Current Issue Past Issues Cover Story Heart Health The Heart Truth Campaign 2009 Past Issues / Winter 2009 Table ... one of the celebrities supporting this year's The Heart Truth campaign. Both R&B singer Ashanti (center) ...

  16. Women's Heart Disease: Heart Disease Risk Factors

    Science.gov (United States)

    ... this page please turn JavaScript on. Feature: Women's Heart Disease Heart Disease Risk Factors Past Issues / Winter 2014 Table ... or habits may raise your risk for coronary heart disease (CHD). These conditions are known as risk ...

  17. Method of burying vessel containing radioactive waste

    International Nuclear Information System (INIS)

    Koga, Yoshihito.

    1989-01-01

    A float having an inert gas sealed therein is attached to a tightly closed vessel containing radioactive wastes. The vessel is inserted and kept in a small hole for burying the tightly closed vessel in an excavated shaft in rocks such as of granite or rock salts, while filling bentonite as shielding material therearound. In this case, the float is so adjusted that the apparent specific gravity is made equal or nearer between the tightly closed vessel and the bentonite, so that the rightly closed vessel does not sink and cause direct contact with the rocks even if bentonite flows due to earthquakes, etc. This can prevent radioactivity contamination through water in the rocks. (S.K.)

  18. Effectiveness of Using Dual-source CT and the Upshot it creates on Both Heart Rate and Image Quality

    Directory of Open Access Journals (Sweden)

    Tuba Selçuk

    2016-06-01

    Full Text Available Background: Early detection of coronary artery disease (CAD is important because of the high morbidity and mortality rates. As invasive coronary angiography (ICA is an invasive procedure, an alternative diagnostic method; coronary computed tomography angiography (CTA, has become more widely used by the improvements in detector technology. Aims: In this study, we aimed to examine the accuracy and image quality of high-pitch 128-slice dual-source CTA taking the ICA as reference technique. We also aimed to compare the accuracy and image quality between different heart rate groups of >70 beates per minute (bpm and ≤70 bpm. Study Design: Retrospective cross-sectional study. Methods: Among 450 patients who underwent coronary CTA with the FLASH spiral technique, performed with a second generation dual-source computed tomography device with a pitch value of 3.2, 102 patients without stent and/or bypass surgery history and clinically suspected coronary artery disease who underwent ICA within 15 days were enrolled. Image quality was assessed by two independent radiologists using a 4-point scale (1=absence of any artifacts- 4=non-evaluable. A stenosis >50% was considered significant on a per-segment, per-vessel, and per-patient basis and ICA was considered the reference method. Radiation doses were determined using dose length product (DLP values detected by the computed tomography (CT device. In addition, patients were classified into two groups according to their heart rates as ≤70 bpm (73 patients and >70 bpm (29 patients. The relation between the diagnostic accuracy and heart rate groups were evaluated. Results: Overall, 1495 (98% coronary segments were diagnostic in 102 patients (32 male, 70 female, mean heart rate: 65 bpm. There was a significant correlation between image quality and mean heart rate in the right coronary artery (RCA segments. The effective radiation dose was 0.98±0.09 mili Sievert (mSv. On a per-patient basis, sensitivity

  19. Life extension of the BR2 aluminium vessel

    International Nuclear Information System (INIS)

    Koonen, E.; Fabry, A.; Chaouadi, R.; Verwerft, M.; Raedt, C. de; Winckel, S. van; Wacquier, W.; Dadoumont, J.; Verwimp, A.

    2000-01-01

    The BR2 reactor has recently undergone a major refurbishment comprising the replacement of all vessel internals. The vessel itself however was not replaced. An important requalification programme has been executed to prove that the vessel would remain fit during the contemplated life extension period of BR2. Representative material samples could be obtained from the shroud surrounding the vessel. A comprehensive in-service inspection was carried out and a vessel surveillance programme has been established. (author)

  20. Comprehending the structure of a vacuum vessel and in-vessel components of fusion machines. 2. Comprehending the divertor structure

    International Nuclear Information System (INIS)

    Suzuki, Satoshi; Akiba, Masato; Saito, Masakatsu

    2006-01-01

    Divertor is given the largest heat load in the in-vessel components of fusion machine. The functions and conditions of divertor are stated from the point of view of thermal and structural dynamics. The way of thinking of structure design of divertor of JT-60 and the ITER (International Thermonuclear Experimental Reactor) is explained. As the conditions of divertor, the materials for large heat load, heat removal, pressure boundary, control of damage, and thermal stress/strain are considered. The divertor has to be changed periodically. The materials are required the heat removal function for high heat load. CuCrZr will be used to cooling tube and heat sink, and CFC materials for the surface. The cross section of ITER, a part of divertor, heat load of divertor and other components, the thermal conductivity of CFC and metal materials, conditions of cooling water for divertor of BWR, PWR and ITER, the thermal stress produced on rod, vertical target of ITER, structure of cooling tube, distribution of temperature and critical heart flux of inner wall of cooling tube, and fatigue clack of cooling tube are shown. (S.Y.)

  1. Probabilistic atlas based labeling of the cerebral vessel tree

    Science.gov (United States)

    Van de Giessen, Martijn; Janssen, Jasper P.; Brouwer, Patrick A.; Reiber, Johan H. C.; Lelieveldt, Boudewijn P. F.; Dijkstra, Jouke

    2015-03-01

    Preoperative imaging of the cerebral vessel tree is essential for planning therapy on intracranial stenoses and aneurysms. Usually, a magnetic resonance angiography (MRA) or computed tomography angiography (CTA) is acquired from which the cerebral vessel tree is segmented. Accurate analysis is helped by the labeling of the cerebral vessels, but labeling is non-trivial due to anatomical topological variability and missing branches due to acquisition issues. In recent literature, labeling the cerebral vasculature around the Circle of Willis has mainly been approached as a graph-based problem. The most successful method, however, requires the definition of all possible permutations of missing vessels, which limits application to subsets of the tree and ignores spatial information about the vessel locations. This research aims to perform labeling using probabilistic atlases that model spatial vessel and label likelihoods. A cerebral vessel tree is aligned to a probabilistic atlas and subsequently each vessel is labeled by computing the maximum label likelihood per segment from label-specific atlases. The proposed method was validated on 25 segmented cerebral vessel trees. Labeling accuracies were close to 100% for large vessels, but dropped to 50-60% for small vessels that were only present in less than 50% of the set. With this work we showed that using solely spatial information of the vessel labels, vessel segments from stable vessels (>50% presence) were reliably classified. This spatial information will form the basis for a future labeling strategy with a very loose topological model.

  2. Comparison of contrast and noncontrast magnetic resonance angiography for quantitative analysis of thoracic arteries in young patients with congenital heart defects

    Directory of Open Access Journals (Sweden)

    Pasqua Alessia

    2011-01-01

    Full Text Available Background : Contrast MRA (C-MRA is the standard for quantitative analysis of thoracic vessels. We evaluated a noncontrast MRA (NC-MRA sequence (3-D EKG and navigator-gated SSFP for quantitative evaluation of the thoracic aorta and branch pulmonary arteries in young patients with congenital heart disease. Objective : To compare contrast and noncontrast magnetic resonance angiography for quantitative analysis of thoracic arteries in young patients with congenital heart defects. Methods : Measurements of thoracic aorta and branch pulmonary arteries were obtained from C-MRA and NC-MRA images in 51 patients, ages 2-35 years. Vessel diameters were compared using correlation and Bland-Altman analysis. Interobserver variability was assessed using percent variation. Results : C-MRA and NC-MRA measurements were highly correlated (r = 0.91-0.98 except for the right pulmonary artery (r = 0.74, 0.78. Agreement of measurements was excellent (mean difference -0.07 to -0.53 mm; mean % difference -1.8 to -4.9% except for the right pulmonary artery which was less good (mean difference 0.73, -1.38 mm; -3, -10%. Interobserver variability ranged from 5% to 8% for aortic and from 10% to 16% for pulmonary artery measures. The worse agreement and greater variability of the pulmonary artery measures appears due to difficulty standardizing the measurements in patients with abnormal and irregular vessels. Conclusion : These data indicate that C-MRA and NC-MRA measures are comparable and could be used interchangeably, avoiding administration of contrast in selected patients.

  3. Reactor pressure vessel status report

    International Nuclear Information System (INIS)

    Strosnider, J.; Wichman, K.; Elliot, B.

    1994-12-01

    This report gives a brief description of the reactor pressure vessel (RPV), followed by a discussion of the radiation embrittlement of RPV beltline materials and the two indicators for measuring embrittlement, the end-of-license (EOL) reference temperature and the EOL upper-shelf energy. It also summarizes the GL 92-01 effort and presents, for all 37 boiling water reactor plants and 74 pressurized water reactor plants in the United States, the current status of compliance with regulatory requirements related to ensuring RPV integrity. The staff has evaluated the material data needed to predict neutron embrittlement of the reactor vessel beltline materials. These data will be stored in a computer database entitled the reactor vessel integrity database (RVID). This database will be updated annually to reflect the changes made by the licensees in future submittals and will be used by the NRC staff to assess the issues related to vessel structural integrity

  4. Modeling the Role of the Glymphatic Pathway and Cerebral Blood Vessel Properties in Alzheimer’s Disease Pathogenesis

    Science.gov (United States)

    Kyrtsos, Christina Rose; Baras, John S.

    2015-01-01

    Alzheimer’s disease (AD) is the most common cause of dementia in the elderly, affecting over 10% population over the age of 65 years. Clinically, AD is described by the symptom set of short term memory loss and cognitive decline, changes in mentation and behavior, and eventually long-term memory deficit as the disease progresses. On imaging studies, significant atrophy with subsequent increase in ventricular volume have been observed. Pathology on post-mortem brain specimens demonstrates the classic findings of increased beta amyloid (Aβ) deposition and the presence of neurofibrillary tangles (NFTs) within affected neurons. Neuroinflammation, dysregulation of blood-brain barrier transport and clearance, deposition of Aβ in cerebral blood vessels, vascular risk factors such as atherosclerosis and diabetes, and the presence of the apolipoprotein E4 allele have all been identified as playing possible roles in AD pathogenesis. Recent research has demonstrated the importance of the glymphatic system in the clearance of Aβ from the brain via the perivascular space surrounding cerebral blood vessels. Given the variety of hypotheses that have been proposed for AD pathogenesis, an interconnected, multilayer model offers a unique opportunity to combine these ideas into a single unifying model. Results of this model demonstrate the importance of vessel stiffness and heart rate in maintaining adequate clearance of Aβ from the brain. PMID:26448331

  5. Influence of heart rate on diagnostic accuracy and image quality of 16-slice CT coronary angiography: comparison of multisegment and halfscan reconstruction approaches

    Energy Technology Data Exchange (ETDEWEB)

    Dewey, Marc; Teige, Florian; Hamm, Bernd [Charite - Universitaetsmedizin Berlin, Humboldt-Universitaet zu Berlin, Department of Radiology, Chariteplatz 1, P.O. Box 10098, Berlin (Germany); Laule, Michael [Department of Cardiology, Charite, Berlin (Germany)

    2007-11-15

    The lower the heart rate the better image quality in multislice computed tomography (MSCT) coronary angiography. We prospectively assessed the influence of heart rate on per-patient diagnostic accuracy and image quality of MSCT coronary angiography and compared adaptive multisegment and standard halfscan reconstruction. A consecutive cohort of 126 patients scheduled to undergo conventional coronary angiography was examined with 16-slice CT. For all heart rate groups, per-patient diagnostic accuracy was significantly higher for multisegment than halfscan reconstruction with values of 95 vs. 79% (p < 0.05, <65 bpm, 38 patients), 85 vs. 66% (p < 0.05, 65-74 bpm, 47 patients), and 78% vs. 41% (p < 0.001, >74 bpm, 41 patients). Differences in diagnostic accuracy between adjacent heart rate groups were only significant for halfscan reconstruction for the comparison between the 65-74 and >74 bpm group (p < 0.05). The vessel lengths free of motion artifacts were significantly longer with multisegment reconstruction in all heart rate groups and for all coronary arteries (p < 0.005). For noninvasive MSCT coronary angiography, both per-patient diagnostic accuracy and image quality decline with increasing heart rate, and multisegment reconstruction at high heart rates yields similar results as standard halfscan reconstruction at low heart rates. (orig.)

  6. Radioactive liquid containing vessel

    International Nuclear Information System (INIS)

    Sakurada, Tetsuo; Kawamura, Hironobu.

    1993-01-01

    Cooling jackets are coiled around the outer circumference of a container vessel, and the outer circumference thereof is covered with a surrounding plate. A liquid of good conductivity (for example, water) is filled between the cooling jackets and the surrounding plate. A radioactive liquid is supplied to the container vessel passing through a supply pipe and discharged passing through a discharge pipe. Cooling water at high pressure is passed through the cooling water jackets in order to remove the heat generated from the radioactive liquid. Since cooling water at high pressure is thus passed through the coiled pipes, the wall thickness of the container vessel and the cooling water jackets can be reduced, thereby enabling to reduce the cost. Further, even if the radioactive liquid is leaked, there is no worry of contaminating cooling water, to prevent contamination. (I.N.)

  7. Big Ship Data: Using vessel measurements to improve estimates of temperature and wind speed on the Great Lakes

    Science.gov (United States)

    Fries, Kevin; Kerkez, Branko

    2017-05-01

    The sheer size of many water systems challenges the ability of in situ sensor networks to resolve spatiotemporal variability of hydrologic processes. New sources of vastly distributed and mobile measurements are, however, emerging to potentially fill these observational gaps. This paper poses the question: How can nontraditional measurements, such as those made by volunteer ship captains, be used to improve hydrometeorological estimates across large surface water systems? We answer this question through the analysis of one of the largest such data sets: an unprecedented collection of one million unique measurements made by ships on the North American Great Lakes from 2006 to 2014. We introduce a flexible probabilistic framework, which can be used to integrate ship measurements, or other sets of irregular point measurements, into contiguous data sets. The performance of this framework is validated through the development of a new ship-based spatial data product of water temperature, air temperature, and wind speed across the Great Lakes. An analysis of the final data product suggests that the availability of measurements across the Great Lakes will continue to play a large role in the confidence with which these large surface water systems can be studied and modeled. We discuss how this general and flexible approach can be applied to similar data sets, and how it will be of use to those seeking to merge large collections of measurements with other sources of data, such as physical models or remotely sensed products.

  8. The pressure vessel for the NSF tandem

    International Nuclear Information System (INIS)

    Jones, C.W.

    1979-04-01

    The pressure vessel is a major component of the 30 MV tandem Van de Graaff electrostatic accelerator to be used in nuclear structure research at Daresbury Laboratory. The accelerator will be capable of accelerating the full range of ions in the form of a beam. Acceleration takes place in a vertical evacuated tube (beam tube) by means of a high potential on a terminal at the central position, the terminal and beam tube assembly being supported by an insulated stack structure within the pressure vessel. Under operating conditions the vessel is filled with sulphur hexafluoride gas (SF 6 ) at high pressure which acts as an insulating medium between the centre terminal and the vessel wall. The vessel is situated inside a concrete tower which besides supporting the injector room above the vessel also acts as radiation shielding around the accelerator. The report covers: functional requirements; fundamental considerations with regard to the design and procurement; detail design; materials; manufacture; acceptance test; surface treatment; final leak test. (U.K.)

  9. Muscle-Specific Mis-Splicing and Heart Disease Exemplified by RBM20.

    Science.gov (United States)

    Rexiati, Maimaiti; Sun, Mingming; Guo, Wei

    2018-01-05

    Alternative splicing is an essential post-transcriptional process to generate multiple functional RNAs or proteins from a single transcript. Progress in RNA biology has led to a better understanding of muscle-specific RNA splicing in heart disease. The recent discovery of the muscle-specific splicing factor RNA-binding motif 20 (RBM20) not only provided great insights into the general alternative splicing mechanism but also demonstrated molecular mechanism of how this splicing factor is associated with dilated cardiomyopathy. Here, we review our current knowledge of muscle-specific splicing factors and heart disease, with an emphasis on RBM20 and its targets, RBM20-dependent alternative splicing mechanism, RBM20 disease origin in induced Pluripotent Stem Cells (iPSCs), and RBM20 mutations in dilated cardiomyopathy. In the end, we will discuss the multifunctional role of RBM20 and manipulation of RBM20 as a potential therapeutic target for heart disease.

  10. Vessel discoloration detection in malarial retinopathy

    Science.gov (United States)

    Agurto, C.; Nemeth, S.; Barriga, S.; Soliz, P.; MacCormick, I.; Taylor, T.; Harding, S.; Lewallen, S.; Joshi, V.

    2016-03-01

    Cerebral malaria (CM) is a life-threatening clinical syndrome associated with malarial infection. It affects approximately 200 million people, mostly sub-Saharan African children under five years of age. Malarial retinopathy (MR) is a condition in which lesions such as whitening and vessel discoloration that are highly specific to CM appear in the retina. Other unrelated diseases can present with symptoms similar to CM, therefore the exact nature of the clinical symptoms must be ascertained in order to avoid misdiagnosis, which can lead to inappropriate treatment and, potentially, death. In this paper we outline the first system to detect the presence of discolored vessels associated with MR as a means to improve the CM diagnosis. We modified and improved our previous vessel segmentation algorithm by incorporating the `a' channel of the CIELab color space and noise reduction. We then divided the segmented vasculature into vessel segments and extracted features at the wall and in the centerline of the segment. Finally, we used a regression classifier to sort the segments into discolored and not-discolored vessel classes. By counting the abnormal vessel segments in each image, we were able to divide the analyzed images into two groups: normal and presence of vessel discoloration due to MR. We achieved an accuracy of 85% with sensitivity of 94% and specificity of 67%. In clinical practice, this algorithm would be combined with other MR retinal pathology detection algorithms. Therefore, a high specificity can be achieved. By choosing a different operating point in the ROC curve, our system achieved sensitivity of 67% with specificity of 100%.

  11. Burden and impact of congenital syndromes and comorbidities among adults with congenital heart disease.

    Science.gov (United States)

    Bracher, Isabelle; Padrutt, Maria; Bonassin, Francesca; Santos Lopes, Bruno; Gruner, Christiane; Stämpfli, Simon F; Oxenius, Angela; De Pasquale, Gabriella; Seeliger, Theresa; Lüscher, Thomas F; Attenhofer Jost, Christine; Greutmann, Matthias

    2017-08-01

    Our aim was to assess the overall burden of congenital syndromes and non-cardiac comorbidities among adults with congenital heart disease and to assess their impact on circumstances of living and outcomes. Within a cohort of 1725 adults with congenital heart defects (65% defects of moderate or great complexity) followed at a single tertiary care center, congenital syndromes and comorbidities were identified by chart review. Their association with arrhythmias, circumstances of living and survival was analyzed. Within the study cohort, 232 patients (13%) had a genetic syndrome, 51% at least one comorbidity and 23% ≥2 comorbidities. Most prevalent comorbidities were systemic arterial hypertension (11%), thyroid dysfunction (9%), psychiatric disorders (9%), neurologic disorders (7%), chronic lung disease (7%), and previous stroke (6%). In contrast to higher congenital heart defect complexity, the presence of comorbidities had no impact on living circumstances but patients with comorbidities were less likely to work full-time. Atrial arrhythmias were more common among patients with moderate/great disease complexity and those with comorbidities but were less common among patients with congenital syndromes (pCongenital syndromes and comorbidities are highly prevalent in adults with congenital heart disease followed at specialist centers and add to the overall complexity of care. The presence of these additional factors has an impact on living circumstances, is associated with arrhythmias and needs to be further explored as prognostic markers. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Proactive life extension of pressure vessels

    Science.gov (United States)

    Mager, Lloyd

    1998-03-01

    For a company to maintain its competitive edge in today's global market every opportunity to gain an advantage must be exploited. Many companies are strategically focusing on improved utilization of existing equipment as well as regulatory compliance. Abbott Laboratories is no exception. Pharmaceutical companies such as Abbott Laboratories realize that reliability and availability of their production equipment is critical to be successful and competitive. Abbott Laboratories, like many of our competitors, is working to improve safety, minimize downtime and maximize the productivity and efficiency of key production equipment such as the pressure vessels utilized in our processes. The correct strategy in obtaining these objectives is to perform meaningful inspection with prioritization based on hazard analysis and risk. The inspection data gathered in Abbott Laboratories pressure vessel program allows informed decisions leading to improved process control. The results of the program are reduced risks to the corporation and employees when operating pressure retaining equipment. Accurate and meaningful inspection methods become the cornerstone of a program allowing proper preventative maintenance actions to occur. Successful preventative/predictive maintenance programs must utilize meaningful nondestructive evaluation techniques and inspection methods. Nondestructive examination methods require accurate useful tools that allow rapid inspection for the entire pressure vessel. Results from the examination must allow the owner to prove compliance of all applicable regulatory laws and codes. At Abbott Laboratories the use of advanced NDE techniques, primarily B-scan ultrasonics, has provided us with the proper tools allowing us to obtain our objectives. Abbott Laboratories uses B-scan ultrasonics utilizing a pulse echo pitch catch technique to provide essential data on our pressure vessels. Equipment downtime is reduced because the nondestructive examination usually takes

  13. Determinants of injuries in passenger vessel accidents.

    Science.gov (United States)

    Yip, Tsz Leung; Jin, Di; Talley, Wayne K

    2015-09-01

    This paper investigates determinants of crew and passenger injuries in passenger vessel accidents. Crew and passenger injury equations are estimated for ferry, ocean cruise, and river cruise vessel accidents, utilizing detailed data of individual vessel accidents that were investigated by the U.S. Coast Guard during the time period 2001-2008. The estimation results provide empirical evidence (for the first time in the literature) that crew injuries are determinants of passenger injuries in passenger vessel accidents. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Heterozygote loss of ACE2 is sufficient to increase the susceptibility to heart disease.

    Science.gov (United States)

    Wang, Wang; Patel, Vaibhav B; Parajuli, Nirmal; Fan, Dong; Basu, Ratnadeep; Wang, Zuocheng; Ramprasath, Tharmarajan; Kassiri, Zamaneh; Penninger, Josef M; Oudit, Gavin Y

    2014-08-01

    Angiotensin-converting enzyme 2 (ACE2) metabolizes Ang II into Ang 1-7 thereby negatively regulating the renin-angiotensin system. However, heart disease in humans and in animal models is associated with only a partial loss of ACE2. ACE2 is an X-linked gene; and as such, we tested the clinical relevance of a partial loss of ACE2 by using female ACE2(+/+) (wildtype) and ACE2(+/-) (heterozygote) mice. Pressure overload in ACE2(+/-) mice resulted in greater LV dilation and worsening systolic and diastolic dysfunction. These changes were associated with increased myocardial fibrosis, hypertrophy, and upregulation of pathological gene expression. In response to Ang II infusion, there was increased NADPH oxidase activity and myocardial fibrosis resulting in the worsening of Ang II-induced diastolic dysfunction with a preserved systolic function. Ang II-mediated cellular effects in cultured adult ACE2(+/-) cardiomyocytes and cardiofibroblasts were exacerbated. Ang II-mediated pathological signaling worsened in ACE2(+/-) hearts characterized by an increase in the phosphorylation of ERK1/2 and JNK1/2 and STAT-3 pathways. The ACE2(+/-) mice showed an exacerbated pressor response with increased vascular fibrosis and stiffness. Vascular superoxide and nitrotyrosine levels were increased in ACE2(+/-) vessels consistent with increased vascular oxidative stress. These changes occurred with increased renal fibrosis and superoxide production. Partial heterozygote loss of ACE2 is sufficient to increase the susceptibility to heart disease secondary to pressure overload and Ang II infusion. Heart disease in humans with idiopathic dilated cardiomyopathy is associated with a partial loss of ACE2. Heterozygote female ACE2 mutant mice showed enhanced susceptibility to pressure overload-induced heart disease. Heterozygote female ACE2 mutant mice showed enhanced susceptibility to Ang II-induced heart and vascular diseases. Partial loss of ACE2 is sufficient to enhance the susceptibility to

  15. The great imitator: IgG4 periaortitis masquerading as an acute aortic syndrome on computed tomographic angiography

    OpenAIRE

    Moore, Drew W.; Hansen, Neil J.; DiMaio, Dominick J.; Harrison, William L.

    2016-01-01

    We present the case of a 52-year-old woman who presented to the emergency department with chest and neck pain. Initial cervical spine magnetic resonance imaging shows an abnormal flow void in the left vertebral artery, which prompted a computed tomographic angiogram. This demonstrated a hyperdense thickened ascending aortic wall, which extended into the great vessel origins. Clinically and radiographically interpreted as an acute aortic syndrome and/or intramural hematoma, the patient underwe...

  16. Improved nuclear reactor construction with bottom supported reactor vessel

    International Nuclear Information System (INIS)

    Sharbaugh, J.E.

    1987-01-01

    An improved liquid metal nuclear reactor construction has a reactor core and a generally cylindrical reactor vessel for holding liquid metal coolant and housing the core within the pool. A generally cylindrical concrete containment structure surrounds the reactor vessel and a central support pedestal is anchored to the containment structure base mat and supports the bottom wall of the reactor vessel and the reactor core. The periphery of the reactor vessel bore is supported by an annular structure which allows thermal expansion but not seismic motion of the vessel, and a bed of thermally insulating material uniformly supports the vessel base whilst allowing expansion thereof. A guard ring prevents lateral seismic motion of the upper end of the reactor vessel. The periphery of the core is supported by an annular structure supported by the vessel base and keyed to the vessel wall so as to be able to expand but not undergo seismic motion. A deck is supported on the containment structure above the reactor vessel open top by annular bellows, the deck carrying the reactor control rods such that heating of the reactor vessel results in upward expansion against the control rods. (author)

  17. 33 CFR 88.11 - Law enforcement vessels.

    Science.gov (United States)

    2010-07-01

    ... NAVIGATION RULES ANNEX V: PILOT RULES § 88.11 Law enforcement vessels. (a) Law enforcement vessels may display a flashing blue light when engaged in direct law enforcement or public safety activities. This... lights. (b) The blue light described in this section may be displayed by law enforcement vessels of the...

  18. 2013 EPA Vessels General Permit (VGP)

    Data.gov (United States)

    U.S. Environmental Protection Agency — Information for any vessel that submitted a Notice of Intent (NOI), Notice of Termination (NOT), or annual report under EPA's 2013 Vessel General Permit (VGP)....

  19. EDS V25 containment vessel explosive qualification test report.

    Energy Technology Data Exchange (ETDEWEB)

    Rudolphi, John Joseph

    2012-04-01

    The V25 containment vessel was procured by the Project Manager, Non-Stockpile Chemical Materiel (PMNSCM) as a replacement vessel for use on the P2 Explosive Destruction Systems. It is the first EDS vessel to be fabricated under Code Case 2564 of the ASME Boiler and Pressure Vessel Code, which provides rules for the design of impulsively loaded vessels. The explosive rating for the vessel based on the Code Case is nine (9) pounds TNT-equivalent for up to 637 detonations. This limit is an increase from the 4.8 pounds TNT-equivalency rating for previous vessels. This report describes the explosive qualification tests that were performed in the vessel as part of the process for qualifying the vessel for explosive use. The tests consisted of a 11.25 pound TNT equivalent bare charge detonation followed by a 9 pound TNT equivalent detonation.

  20. Characterizing potential heart agents with an isolated perfused heart system

    International Nuclear Information System (INIS)

    Pendleton, D.B.; Sands, H.; Gallagher, B.M.; Camin, L.L.

    1984-01-01

    The authors have used an isolated perfused heart system for characterizing potential myocardial perfusion radiopharamaceuticals. Rabbit or guinea pig (GP) hearts are removed and perfused through the aorta with a blood-free buffer. Heart rate and ventricular pressure are monitored as indices of viability. Tc-99m-MAA is 96-100% retained in these hearts, and Tc-99m human serum albumin shows less than 5% extraction. Tl-201 is 30-40% extracted. It is known that in-vivo, Tc-99m(dmpe)/sub 2/Cl/sub 2//sup +/ is taken up by rabbit heart but not by GP or human heart. Analogous results are obtained with the isolated perfused heart model, where the complex is extracted well by the isolated rabbit heart (24%) but not by the GP heart (<5%). Values are unchanged if human, rabbit or GP blood is mixed and co-injected with the complex. Tc-99m)dmpe)/sub 3//sup +/ is also taken up by rabbit but not by GP hearts in-vivo. However, isolated perfused hearts of both species extract this complex well (45-52%). Heart uptake is diminished to <7% if the complex is pre-equilibrated with human blood. GP blood produces a moderate inhibition (in GP hearts only) and rabbit blood has no effect. This suggests that a human or GP blood factor may have a significant effect on heart uptake of this complex. Tc-99m(CN-t-butyl)/sub 6//sup +/ is taken up well by both rabbit and GP hearts in-vivo, and is extracted 100% by both isolated perfused hearts. Heart retention remains high (73-75%) in the presence of human blood