WorldWideScience

Sample records for hearing aid effectiveness

  1. Comparing Analog and Digital Hearing Aids in Reducing Hearing Disability

    Directory of Open Access Journals (Sweden)

    Ghassem Mohammad Khani

    2004-06-01

    Full Text Available Objective: Comparing analog and digital hearing aids reducing disability caused by hearing deficiency among moderate to severe sensorineural hearing-impaired persons. Method and Material: This descriptive-analytic study was carried out on two groups of subjects participated in this study in some audiology clinics of hearing aid since May 2002 to October 2003. Twenty subjects wore analog hearing aids and twenty one subjects wore digital hearing aids. In this study , no subject had previous middle ear or psychological problems. APHAB questionnaire was completed before using hearing aid and 2 months after to determine benefit of hearing aid use. Results: Total score mean of APHAB inventory before and after use of analoge hearing aids were 52.215+6.420 and 32.300+3.443 respectively. Also total score mean of APHAB inventory before and after use of digital hearing aids were 54.9252+9.028 and 26.321+10.916 respectively. There was no significant difference between total mean score of APHAB inventory before and after using analog and digital hearing aids (P=0.058.While there was significant difference between total mean score of APHAB questionnaire before and after use of analog hearing aids (P<0.001 and also before and after use of digital hearing aids (P<0.001. Moreover age, gender , litracy level , occupation , degree of hearing loss and manner of hearing aid usage did not have significant effect on APHAB results. Configuration of loss had siginficant effect on aversiveness subscale before and after use of analog hearing aids (P=0.008. Previous experience and duration of hearing aid usage had significant effect on aversiveness subscale before and after use of digital hearing aids (P=0.043 and (P=0.024, respectively , while all of these three items did not have significant effect on total mean score of APHAB inventory and also total mean scores of three subscales of ease of communication , reverberation and background noise. Conclusion: Comparing to

  2. Music and hearing aids.

    Science.gov (United States)

    Madsen, Sara M K; Moore, Brian C J

    2014-10-31

    The signal processing and fitting methods used for hearing aids have mainly been designed to optimize the intelligibility of speech. Little attention has been paid to the effectiveness of hearing aids for listening to music. Perhaps as a consequence, many hearing-aid users complain that they are not satisfied with their hearing aids when listening to music. This issue inspired the Internet-based survey presented here. The survey was designed to identify the nature and prevalence of problems associated with listening to live and reproduced music with hearing aids. Responses from 523 hearing-aid users to 21 multiple-choice questions are presented and analyzed, and the relationships between responses to questions regarding music and questions concerned with information about the respondents, their hearing aids, and their hearing loss are described. Large proportions of the respondents reported that they found their hearing aids to be helpful for listening to both live and reproduced music, although less so for the former. The survey also identified problems such as distortion, acoustic feedback, insufficient or excessive gain, unbalanced frequency response, and reduced tone quality. The results indicate that the enjoyment of listening to music with hearing aids could be improved by an increase of the input and output dynamic range, extension of the low-frequency response, and improvement of feedback cancellation and automatic gain control systems. © The Author(s) 2014.

  3. Music and Hearing Aids

    Directory of Open Access Journals (Sweden)

    Sara M. K. Madsen

    2014-10-01

    Full Text Available The signal processing and fitting methods used for hearing aids have mainly been designed to optimize the intelligibility of speech. Little attention has been paid to the effectiveness of hearing aids for listening to music. Perhaps as a consequence, many hearing-aid users complain that they are not satisfied with their hearing aids when listening to music. This issue inspired the Internet-based survey presented here. The survey was designed to identify the nature and prevalence of problems associated with listening to live and reproduced music with hearing aids. Responses from 523 hearing-aid users to 21 multiple-choice questions are presented and analyzed, and the relationships between responses to questions regarding music and questions concerned with information about the respondents, their hearing aids, and their hearing loss are described. Large proportions of the respondents reported that they found their hearing aids to be helpful for listening to both live and reproduced music, although less so for the former. The survey also identified problems such as distortion, acoustic feedback, insufficient or excessive gain, unbalanced frequency response, and reduced tone quality. The results indicate that the enjoyment of listening to music with hearing aids could be improved by an increase of the input and output dynamic range, extension of the low-frequency response, and improvement of feedback cancellation and automatic gain control systems.

  4. Hearing aid fitting in older persons with hearing impairment: the influence of cognitive function, age, and hearing loss on hearing aid benefit.

    Science.gov (United States)

    Meister, Hartmut; Rählmann, Sebastian; Walger, Martin; Margolf-Hackl, Sabine; Kießling, Jürgen

    2015-01-01

    To examine the association of cognitive function, age, and hearing loss with clinically assessed hearing aid benefit in older hearing-impaired persons. Hearing aid benefit was assessed using objective measures regarding speech recognition in quiet and noisy environments as well as a subjective measure reflecting everyday situations captured using a standardized questionnaire. A broad range of general cognitive functions such as attention, memory, and intelligence were determined using different neuropsychological tests. Linear regression analyses were conducted with the outcome of the neuropsychological tests as well as age and hearing loss as independent variables and the benefit measures as dependent variables. Thirty experienced older hearing aid users with typical age-related hearing impairment participated. Most of the benefit measures revealed that the participants obtained significant improvement with their hearing aids. Regression models showed a significant relationship between a fluid intelligence measure and objective hearing aid benefit. When individual hearing thresholds were considered as an additional independent variable, hearing loss was the only significant contributor to the benefit models. Lower cognitive capacity - as determined by the fluid intelligence measure - was significantly associated with greater hearing loss. Subjective benefit could not be predicted by any of the variables considered. The present study does not give evidence that hearing aid benefit is critically associated with cognitive function in experienced hearing aid users. However, it was found that lower fluid intelligence scores were related to higher hearing thresholds. Since greater hearing loss was associated with a greater objective benefit, these results strongly support the advice of using hearing aids regardless of age and cognitive function to counter hearing loss and the adverse effects of age-related hearing impairment. Still, individual cognitive capacity might

  5. Does hearing aid use affect audiovisual integration in mild hearing impairment?

    Science.gov (United States)

    Gieseler, Anja; Tahden, Maike A S; Thiel, Christiane M; Colonius, Hans

    2018-04-01

    There is converging evidence for altered audiovisual integration abilities in hearing-impaired individuals and those with profound hearing loss who are provided with cochlear implants, compared to normal-hearing adults. Still, little is known on the effects of hearing aid use on audiovisual integration in mild hearing loss, although this constitutes one of the most prevalent conditions in the elderly and, yet, often remains untreated in its early stages. This study investigated differences in the strength of audiovisual integration between elderly hearing aid users and those with the same degree of mild hearing loss who were not using hearing aids, the non-users, by measuring their susceptibility to the sound-induced flash illusion. We also explored the corresponding window of integration by varying the stimulus onset asynchronies. To examine general group differences that are not attributable to specific hearing aid settings but rather reflect overall changes associated with habitual hearing aid use, the group of hearing aid users was tested unaided while individually controlling for audibility. We found greater audiovisual integration together with a wider window of integration in hearing aid users compared to their age-matched untreated peers. Signal detection analyses indicate that a change in perceptual sensitivity as well as in bias may underlie the observed effects. Our results and comparisons with other studies in normal-hearing older adults suggest that both mild hearing impairment and hearing aid use seem to affect audiovisual integration, possibly in the sense that hearing aid use may reverse the effects of hearing loss on audiovisual integration. We suggest that these findings may be particularly important for auditory rehabilitation and call for a longitudinal study.

  6. The Master Hearing Aid

    Science.gov (United States)

    Curran, James R.

    2013-01-01

    As early as the 1930s the term Master Hearing Aid (MHA) described a device used in the fitting of hearing aids. In their original form, the MHA was a desktop system that allowed for simulated or actual adjustment of hearing aid components that resulted in a changed hearing aid response. Over the years the MHA saw many embodiments and contributed to a number of rationales for the fitting of hearing aids. During these same years, the MHA was viewed by many as an inappropriate means of demonstrating hearing aids; the audio quality of the desktop systems was often superior to the hearing aids themselves. These opinions and the evolution of the MHA have molded the modern perception of hearing aids and the techniques used in the fitting of hearing aids. This article reports on a history of the MHA and its influence on the fitting of hearing aids. PMID:23686682

  7. Treatment Efficacy: Hearing Aids in the Management of Hearing Loss in Adults.

    Science.gov (United States)

    Weinstein, Barbara E.

    1996-01-01

    This article reviews the efficacy of hearing aids in adults with hearing impairments. Information is provided on the prevalence of hearing impairments; the daily effects of a hearing impairment; and the role of the audiologist. The effectiveness and benefits of hearing aids are reviewed, and a case study is provided. (CR)

  8. Assisting Older Persons With Adjusting to Hearing Aids.

    Science.gov (United States)

    Lane, Kari R; Clark, M Kathleen

    2016-02-01

    This intervention study tested the feasibility and initial effect of Hearing Aid Reintroduction (HEAR) to assist persons aged 70 to 85 years adjust to hearing aids. Following this 30-day intervention, hearing aid use increased between 1 and 8 hr per day with 50% of participants able to wear them for at least 4 hr. Hearing aid satisfaction improved from not satisfied to satisfied overall. The study demonstrated that HEAR is feasible and could improve hearing aid use of a substantial number of older persons who had previously failed to adjust to their hearing aids and had given up. However, further testing among a larger and more diverse population is needed to better understand the effectiveness and sustainability of the intervention. © The Author(s) 2014.

  9. [Hearing aid application performance evaluation questionnaire to presbycusis].

    Science.gov (United States)

    Chen, Xianghong; Zhou, Huifang; Zhang, Jing; Wang, Liqun

    2011-02-01

    By matching patients with presbycusis hearing aids,hearing aid performance assessment questionnaire to fill out to assess the effect of its use and targeted to solve problems encountered in its use and improve the quality of life of older persons. Through face to face way to investigate and analyse patients with hearing aids fitting, totally 30 subjects accepted the analysis, preliminary assessment of the use of hearing aids in patient with presbycusis results and solve problems encountered in its use by using SPSS software to analyze the collecting data. HHIE questionnaire on statistical analysis, obtained in patients with hearing loss use hearing aids after the problem is a significant improvement statistical analysis of the SADL questionnaire, the conclusion is relatively satisfied with the overall satisfaction. Effects Assessment Questionnaire in patients with hearing aids hearing impairment can be epitomized the disabled after use to improve the situation and understand the satisfaction of patients with hearing aids can be an initial effect as the rehabilitation of a reliable subjective assessment of the impact assessment indicators.

  10. Effects of hearing aids on cognitive functions and depressive signs in elderly people.

    Science.gov (United States)

    Acar, Baran; Yurekli, Muge Fethiye; Babademez, Mehmet Ali; Karabulut, Hayriye; Karasen, Rıza Murat

    2011-01-01

    With the physical, emotional and cognitive effects of senility, elderly people, especially those with impaired hearing, need rehabilitation for improving their life conditions. Hearing aids are frequently used to improve their daily life communications and activities. The aim of this study was to report the cognitive and psychological benefits of using hearing aids by the elderly people, over the age of 65. This was a prospective, single-arm interventional study in 34 elderly subjects with hearing impairment who answered the geriatric depression scale-short form (GDS) questionnaire and the mini mental state examination (MMSE) test, prior to, and 3 months following the use of hearing aid, after obtaining the patients' consent to participate in study. Patients with evidence of focal neurological loss with clinical examination, a confusional state, sudden hear loss and severe tinnitus were not included in the study. Scores of the effects of hearing aids on mood and cognitive functions were compared for each subject, before and after, and between males and females. After 3 months of using a hearing aid, all patients showed a significant improvement of the psychosocial and cognitive conditions, and all of them showed betterment of their problems, i.e., the social communication and exchanging information. In conclusion, for the elderly people with the effects of hearing aids in presbycusis and due to the significant improvement in psychological state and mental functions, using and being adaptable to hearing aids is a good solution. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  11. Effects of Hearing Impairment and Hearing Aid Amplification on Listening Effort: A Systematic Review.

    Science.gov (United States)

    Ohlenforst, Barbara; Zekveld, Adriana A; Jansma, Elise P; Wang, Yang; Naylor, Graham; Lorens, Artur; Lunner, Thomas; Kramer, Sophia E

    To undertake a systematic review of available evidence on the effect of hearing impairment and hearing aid amplification on listening effort. Two research questions were addressed: Q1) does hearing impairment affect listening effort? and Q2) can hearing aid amplification affect listening effort during speech comprehension? English language articles were identified through systematic searches in PubMed, EMBASE, Cinahl, the Cochrane Library, and PsycINFO from inception to August 2014. References of eligible studies were checked. The Population, Intervention, Control, Outcomes, and Study design strategy was used to create inclusion criteria for relevance. It was not feasible to apply a meta-analysis of the results from comparable studies. For the articles identified as relevant, a quality rating, based on the 2011 Grading of Recommendations Assessment, Development, and Evaluation Working Group guidelines, was carried out to judge the reliability and confidence of the estimated effects. The primary search produced 7017 unique hits using the keywords: hearing aids OR hearing impairment AND listening effort OR perceptual effort OR ease of listening. Of these, 41 articles fulfilled the Population, Intervention, Control, Outcomes, and Study design selection criteria of: experimental work on hearing impairment OR hearing aid technologies AND listening effort OR fatigue during speech perception. The methods applied in those articles were categorized into subjective, behavioral, and physiological assessment of listening effort. For each study, the statistical analysis addressing research question Q1 and/or Q2 was extracted. In seven articles more than one measure of listening effort was provided. Evidence relating to Q1 was provided by 21 articles that reported 41 relevant findings. Evidence relating to Q2 was provided by 27 articles that reported 56 relevant findings. The quality of evidence on both research questions (Q1 and Q2) was very low, according to the Grading of

  12. Music preferences with hearing aids: effects of signal properties, compression settings, and listener characteristics.

    Science.gov (United States)

    Croghan, Naomi B H; Arehart, Kathryn H; Kates, James M

    2014-01-01

    Current knowledge of how to design and fit hearing aids to optimize music listening is limited. Many hearing-aid users listen to recorded music, which often undergoes compression limiting (CL) in the music industry. Therefore, hearing-aid users may experience twofold effects of compression when listening to recorded music: music-industry CL and hearing-aid wide dynamic-range compression (WDRC). The goal of this study was to examine the roles of input-signal properties, hearing-aid processing, and individual variability in the perception of recorded music, with a focus on the effects of dynamic-range compression. A group of 18 experienced hearing-aid users made paired-comparison preference judgments for classical and rock music samples using simulated hearing aids. Music samples were either unprocessed before hearing-aid input or had different levels of music-industry CL. Hearing-aid conditions included linear gain and individually fitted WDRC. Combinations of four WDRC parameters were included: fast release time (50 msec), slow release time (1,000 msec), three channels, and 18 channels. Listeners also completed several psychophysical tasks. Acoustic analyses showed that CL and WDRC reduced temporal envelope contrasts, changed amplitude distributions across the acoustic spectrum, and smoothed the peaks of the modulation spectrum. Listener judgments revealed that fast WDRC was least preferred for both genres of music. For classical music, linear processing and slow WDRC were equally preferred, and the main effect of number of channels was not significant. For rock music, linear processing was preferred over slow WDRC, and three channels were preferred to 18 channels. Heavy CL was least preferred for classical music, but the amount of CL did not change the patterns of WDRC preferences for either genre. Auditory filter bandwidth as estimated from psychophysical tuning curves was associated with variability in listeners' preferences for classical music. Fast

  13. Hearing Aid and children

    Directory of Open Access Journals (Sweden)

    Jamileh Fatahi

    2002-07-01

    Full Text Available In order to develop oral communication, hearing impaired infants and young children must be able to hear speech comfortably and consistently. To day children with all degrees of hearing loss may be condidates for some kinds of amlification. As children differ from adults, many Factors should be consider in hearing aid selection, evaluation and fitting. For example the child age when he or she is candidate for custom instruments? Do we consider programmable Hearing aid? Are multi memory instruments appropriate for them? What about directional microphones? What style of hearing aid do we select? In this paper such questions are Answered.

  14. The effect of hearing aid noise reduction on listening effort in hearing-impaired adults.

    Science.gov (United States)

    Desjardins, Jamie L; Doherty, Karen A

    2014-01-01

    The purpose of the present study was to evaluate the effect of a noise-reduction (NR) algorithm on the listening effort hearing-impaired participants expend on a speech in noise task. Twelve hearing-impaired listeners fitted with behind-the-ear hearing aids with a fast-acting modulation-based NR algorithm participated in this study. A dual-task paradigm was used to measure listening effort with and without the NR enabled in the hearing aid. The primary task was a sentence-in-noise task presented at fixed overall speech performance levels of 76% (moderate listening condition) and 50% (difficult listening condition) correct performance, and the secondary task was a visual-tracking test. Participants also completed measures of working memory (Reading Span test), and processing speed (Digit Symbol Substitution Test) ability. Participants' speech recognition in noise scores did not significantly change with the NR algorithm activated in the hearing aid in either listening condition. The NR algorithm significantly decreased listening effort, but only in the more difficult listening condition. Last, there was a tendency for participants with faster processing speeds to expend less listening effort with the NR algorithm when listening to speech in background noise in the difficult listening condition. The NR algorithm reduced the listening effort adults with hearing loss must expend to understand speech in noise.

  15. Buying a Hearing Aid

    Science.gov (United States)

    ... the aids? Start using your hearing aids in quiet surroundings, gradually building up to noisier environments. Then eventually work up to wearing your hearing aids all waking hours. Keep a diary to help you remember your ...

  16. The Effect of Functional Hearing and Hearing Aid Usage on Verbal Reasoning in a Large Community-Dwelling Population.

    Science.gov (United States)

    Keidser, Gitte; Rudner, Mary; Seeto, Mark; Hygge, Staffan; Rönnberg, Jerker

    2016-01-01

    Verbal reasoning performance is an indicator of the ability to think constructively in everyday life and relies on both crystallized and fluid intelligence. This study aimed to determine the effect of functional hearing on verbal reasoning when controlling for age, gender, and education. In addition, the study investigated whether hearing aid usage mitigated the effect and examined different routes from hearing to verbal reasoning. Cross-sectional data on 40- to 70-year-old community-dwelling participants from the UK Biobank resource were accessed. Data consisted of behavioral and subjective measures of functional hearing, assessments of numerical and linguistic verbal reasoning, measures of executive function, and demographic and lifestyle information. Data on 119,093 participants who had completed hearing and verbal reasoning tests were submitted to multiple regression analyses, and data on 61,688 of these participants, who had completed additional cognitive tests and provided relevant lifestyle information, were submitted to structural equation modeling. Poorer performance on the behavioral measure of functional hearing was significantly associated with poorer verbal reasoning in both the numerical and linguistic domains (p reasoning. Functional hearing significantly interacted with education (p reasoning among those with a higher level of formal education. Among those with poor hearing, hearing aid usage had a significant positive, but not necessarily causal, effect on both numerical and linguistic verbal reasoning (p reasoning and showed that controlling for executive function eliminated the effect. However, when computer usage was controlled for, the eliminating effect of executive function was weakened. Poor functional hearing was associated with poor verbal reasoning in a 40- to 70-year-old community-dwelling population after controlling for age, gender, and education. The effect of functional hearing on verbal reasoning was significantly reduced among

  17. The Effects of Hearing Aids on Localization of White Noise by Blind Subjects.

    Science.gov (United States)

    Bergen, Bruce R.

    1980-01-01

    An investigation was conducted to observe the effects of hearing aids on the ability of 20 blind veterans to localize white noise. In all cases, Ss performed more poorly on a localization task while wearing a hearing aid. (Author)

  18. Hearing aid controlled by binaural source localizer

    NARCIS (Netherlands)

    2009-01-01

    An adaptive directional hearing aid system comprising a left hearing aid and a right hearing aid, wherein a binaural acoustic source localizer is located in the left hearing aid or in the right hearing aid or in a separate body- worn device connected wirelessly to the left hearing aid and the right

  19. The effect of hearing aid signal-processing schemes on acceptable noise levels: perception and prediction.

    Science.gov (United States)

    Wu, Yu-Hsiang; Stangl, Elizabeth

    2013-01-01

    The acceptable noise level (ANL) test determines the maximum noise level that an individual is willing to accept while listening to speech. The first objective of the present study was to systematically investigate the effect of wide dynamic range compression processing (WDRC), and its combined effect with digital noise reduction (DNR) and directional processing (DIR), on ANL. Because ANL represents the lowest signal-to-noise ratio (SNR) that a listener is willing to accept, the second objective was to examine whether the hearing aid output SNR could predict aided ANL across different combinations of hearing aid signal-processing schemes. Twenty-five adults with sensorineural hearing loss participated in the study. ANL was measured monaurally in two unaided and seven aided conditions, in which the status of the hearing aid processing schemes (enabled or disabled) and the location of noise (front or rear) were manipulated. The hearing aid output SNR was measured for each listener in each condition using a phase-inversion technique. The aided ANL was predicted by unaided ANL and hearing aid output SNR, under the assumption that the lowest acceptable SNR at the listener's eardrum is a constant across different ANL test conditions. Study results revealed that, on average, WDRC increased (worsened) ANL by 1.5 dB, while DNR and DIR decreased (improved) ANL by 1.1 and 2.8 dB, respectively. Because the effects of WDRC and DNR on ANL were opposite in direction but similar in magnitude, the ANL of linear/DNR-off was not significantly different from that of WDRC/DNR-on. The results further indicated that the pattern of ANL change across different aided conditions was consistent with the pattern of hearing aid output SNR change created by processing schemes. Compared with linear processing, WDRC creates a noisier sound image and makes listeners less willing to accept noise. However, this negative effect on noise acceptance can be offset by DNR, regardless of microphone mode

  20. Hearing aid adjustment

    DEFF Research Database (Denmark)

    Heinemann, Trine; Matthews, Ben; Raudaskoski, Pirkko Liisa

    2012-01-01

    to the interaction during hearing aid fitting. This report of a Danish pilot study describes two such problems. The first problem arises from the requirement that the audiologist needs to ‘translate’ the patient’s subjective hearing description for making technological decisions. The second problem is the way...... in which the hearing aid user’s implicit and often unrealistic expectations are handled. This kind of research has potential application for developing a model of best practices....

  1. The learning hearing aid: common-sense reasoning in hearing aid circuits

    NARCIS (Netherlands)

    Dijkstra, T.M.H.; Ypma, A.; Vries, de B.; Leenen, J.R.G.M.

    2007-01-01

    This article discusses how hearing aid engineers have applied the Bayesian probability theory approach to the problem of hearing aid fitting. Currently more an art than a science, it is likely that probability theory will play a large role in future generations of fitting software used by dispensing

  2. Intelligent hearing aids: the next revolution.

    Science.gov (United States)

    Tao Zhang; Mustiere, Fred; Micheyl, Christophe

    2016-08-01

    The first revolution in hearing aids came from nonlinear amplification, which allows better compensation for both soft and loud sounds. The second revolution stemmed from the introduction of digital signal processing, which allows better programmability and more sophisticated algorithms. The third revolution in hearing aids is wireless, which allows seamless connectivity between a pair of hearing aids and with more and more external devices. Each revolution has fundamentally transformed hearing aids and pushed the entire industry forward significantly. Machine learning has received significant attention in recent years and has been applied in many other industries, e.g., robotics, speech recognition, genetics, and crowdsourcing. We argue that the next revolution in hearing aids is machine intelligence. In fact, this revolution is already quietly happening. We will review the development in at least three major areas: applications of machine learning in speech enhancement; applications of machine learning in individualization and customization of signal processing algorithms; applications of machine learning in improving the efficiency and effectiveness of clinical tests. With the advent of the internet of things, the above developments will accelerate. This revolution will bring patient satisfactions to a new level that has never been seen before.

  3. Hearing Aid Personalization

    DEFF Research Database (Denmark)

    Nielsen, Jens Brehm; Nielsen, Jakob; Jensen, Bjørn Sand

    2013-01-01

    Modern digital hearing aids require and offer a great level of personalization. Today, this personalization is not performed based directly on what the user actually perceives, but on a hearing-care professional’s interpretation of what the user explains about what is perceived. In this paper......, an interactive personalization system based on Gaussian process regression and active learning is proposed, which personalize the hearing aids based directly on what the user perceives. Preliminary results demonstrate a significant difference between a truly personalized setting obtained with the proposed system...

  4. Auditory-model based assessment of the effects of hearing loss and hearing-aid compression on spectral and temporal resolution

    DEFF Research Database (Denmark)

    Kowalewski, Borys; MacDonald, Ewen; Strelcyk, Olaf

    2016-01-01

    . However, due to the complexity of speech and its robustness to spectral and temporal alterations, the effects of DRC on speech perception have been mixed and controversial. The goal of the present study was to obtain a clearer understanding of the interplay between hearing loss and DRC by means......Most state-of-the-art hearing aids apply multi-channel dynamic-range compression (DRC). Such designs have the potential to emulate, at least to some degree, the processing that takes place in the healthy auditory system. One way to assess hearing-aid performance is to measure speech intelligibility....... Outcomes were simulated using the auditory processing model of Jepsen et al. (2008) with the front end modified to include effects of hearing impairment and DRC. The results were compared to experimental data from normal-hearing and hearing-impaired listeners....

  5. How to Get Hearing Aids

    Science.gov (United States)

    ... if desired. What questions should I ask before buying hearing aids? Before you buy a hearing aid, ... the period of warranty? Does the warranty cover future maintenance and repairs? Will loaner aids be provided ...

  6. Hearing Aids Communication

    DEFF Research Database (Denmark)

    Globally, hearing loss is the second most frequent disability. About 80% of the persons affected by hearing loss do not use hearing aids. The goal of this edited volume is to present a theoretically founded, interdisciplinary approach geared at understanding and improving social interaction...

  7. Effects of acoustical stimuli delivered through hearing aids on tinnitus.

    Science.gov (United States)

    Sweetow, Robert W; Sabes, Jennifer Henderson

    2010-01-01

    The use of acoustic signals to mask, mix with, or ease the distress associated with tinnitus has been clinically employed for decades. It has been proposed that expanding acoustic options for tinnitus sufferers due to personal preferences is desirable. Fractal tones incorporate many useful characteristics of music while avoiding certain features that could be distracting to some individuals. To assess the effects on relaxation, tinnitus annoyance, tinnitus handicap, and tinnitus reaction from the use of a hearing aid that incorporates combinations of amplification, fractal tones, and white noise. Participants listened to experimental hearing aids containing several acoustic options and were asked to rate the signals in terms of their effect on relaxation and tinnitus annoyance. They subsequently wore the hearing aids for 6 mo and completed tinnitus handicap and reaction scales. Fourteen hearing-impaired adults with primary complaints of subjective tinnitus. Participants were tested wearing hearing aids containing several programs including amplification only, fractal tones only, and a combination of amplification, noise, and/or fractal tones. The fractal tones (now commercially available as the "Zen" feature) were generated by the Widex Mind hearing aid. Rating procedures were conducted in the laboratory, and tinnitus reaction and handicap were assessed during and following a 6 mo field trial. Data were collected at the initial visit, one week, 1 mo, 3 mo, and 6 mo. Nonparametric statistics included Wilcoxon matched-pairs signed-rank, chi(2), and repeated-measures analyses of variance. Thirteen of 14 participants reported that their tinnitus annoyance, as measured by the Tinnitus Annoyance Scale, was reduced for at least one of the amplified conditions (with or without fractal tones or noise), relative to the unaided condition. Nine assigned a lower tinnitus annoyance rating when listening to fractal tones alone versus the amplification-alone condition. There was a

  8. Costs and health effects of screening and delivery of hearing aids in Tamil Nadu, India: an observational study

    Directory of Open Access Journals (Sweden)

    Job Anand

    2009-05-01

    Full Text Available Abstract Background The burden of disease of hearing disorders among adults is high, but a significant part goes undetected. Screening programs in combination with the delivery of hearing aids can alleviate this situation, but the economic attractiveness of such programs is unknown. This study aims to evaluate the population-level costs, effects and cost-effectiveness of alternative delivering hearing aids models in Tamil Nadu, India Methods In an observational study design, we estimated total costs and effects of two active screening programs in the community in combination with the provision of hearing aids at secondary care level, and the costs and effects of the provision of hearing aids at tertiary care level. Screening and hearing aid delivery costs were estimated on the basis of program records and an empirical assessment of health personnel time input. Household costs for seeking and undergoing hearing health care were collected with a questionnaire (see Additional file 2. Health effects were estimated on the basis of compliance with the hearing aid, and associated changes in disability, and were expressed in disability-adjusted life years (DALYs averted. Results Active screening and provision of hearing aids at the secondary care level costs around Rs.7,000 (US$152 per patient, whereas provision of hearing aids at the tertiary care level costs Rs 5,693 (US$122 per patient. The cost per DALY averted was around RS 42,200 (US$900 at secondary care level and Rs 33,900 (US$720 at tertiary care level. The majority of people did consult other providers before being screened in the community. Costs of food and transport ranged between Rs. 2 (US$0,04 and Rs. 39 (US$0,83. Conclusion Active screening and provision of hearing aids at the secondary care level is slightly more costly than passive screening and fitting of hearing aids at the tertiary care level, but seems also able to reach a higher coverage of hearing aids services. Although crude

  9. Challenges in IC design for hearing aids

    DEFF Research Database (Denmark)

    Jørgensen, Ivan Harald Holger

    2012-01-01

    Designing modern hearing aids is a formidable challenge. The size of hearing aids is constantly decreasing, making them virtually invisible today. Still, as in all other modern electronics, more and more features are added to these devices driven by the development in modern IC technology....... The demands for performance and features at very low supply voltage and power consumption constantly prove a challenge to the physical design of hearing aids and not at least the design of the ICs for these. As a result of this all large hearing aid manufacturers use fully customized ASICs in their products...... to produce a competitive advantage. This presentation will give a brief insight into the hearing aid market and industry, a brief view of the historic development of hearing aids and an introduction to how a modern hearing is constructed showing the amplifier as the key component in the modern hearing aid...

  10. Formal auditory training in adult hearing aid users

    Directory of Open Access Journals (Sweden)

    Daniela Gil

    2010-01-01

    Full Text Available INTRODUCTION: Individuals with sensorineural hearing loss are often able to regain some lost auditory function with the help of hearing aids. However, hearing aids are not able to overcome auditory distortions such as impaired frequency resolution and speech understanding in noisy environments. The coexistence of peripheral hearing loss and a central auditory deficit may contribute to patient dissatisfaction with amplification, even when audiological tests indicate nearly normal hearing thresholds. OBJECTIVE: This study was designed to validate the effects of a formal auditory training program in adult hearing aid users with mild to moderate sensorineural hearing loss. METHODS: Fourteen bilateral hearing aid users were divided into two groups: seven who received auditory training and seven who did not. The training program was designed to improve auditory closure, figure-to-ground for verbal and nonverbal sounds and temporal processing (frequency and duration of sounds. Pre- and post-training evaluations included measuring electrophysiological and behavioral auditory processing and administration of the Abbreviated Profile of Hearing Aid Benefit (APHAB self-report scale. RESULTS: The post-training evaluation of the experimental group demonstrated a statistically significant reduction in P3 latency, improved performance in some of the behavioral auditory processing tests and higher hearing aid benefit in noisy situations (p-value < 0,05. No changes were noted for the control group (p-value <0,05. CONCLUSION: The results demonstrated that auditory training in adult hearing aid users can lead to a reduction in P3 latency, improvements in sound localization, memory for nonverbal sounds in sequence, auditory closure, figure-to-ground for verbal sounds and greater benefits in reverberant and noisy environments.

  11. Assessment of hearing aid algorithms using a master hearing aid: the influence of hearing aid experience on the relationship between speech recognition and cognitive capacity.

    Science.gov (United States)

    Rählmann, Sebastian; Meis, Markus; Schulte, Michael; Kießling, Jürgen; Walger, Martin; Meister, Hartmut

    2017-04-27

    Model-based hearing aid development considers the assessment of speech recognition using a master hearing aid (MHA). It is known that aided speech recognition in noise is related to cognitive factors such as working memory capacity (WMC). This relationship might be mediated by hearing aid experience (HAE). The aim of this study was to examine the relationship of WMC and speech recognition with a MHA for listeners with different HAE. Using the MHA, unaided and aided 80% speech recognition thresholds in noise were determined. Individual WMC capacity was assed using the Verbal Learning and Memory Test (VLMT) and the Reading Span Test (RST). Forty-nine hearing aid users with mild to moderate sensorineural hearing loss divided into three groups differing in HAE. Whereas unaided speech recognition did not show a significant relationship with WMC, a significant correlation could be observed between WMC and aided speech recognition. However, this only applied to listeners with HAE of up to approximately three years, and a consistent weakening of the correlation could be observed with more experience. Speech recognition scores obtained in acute experiments with an MHA are less influenced by individual cognitive capacity when experienced HA users are taken into account.

  12. Benefit of Analog, Programmable and Digital Hearing Aids

    Directory of Open Access Journals (Sweden)

    Jamileh Fatahi

    2006-12-01

    Full Text Available Background and Aims: As the hearing aid technology progressively promotes toward replacing analog hearing aids with digital and programmable ones, comparison of the patient satisfaction of those kinds of hearing aids by means of a valuable tool seems so necessary. So, the aim of this study was to compare self-reported benefit of analog, digitally controlled programmable and digital hearing aids for reducing disability caused by hearing impairment in mild to severe sensorineural hearing impaired persons. Materials and Methods: This cross-sectional study was performed on 90 persons with mild to severe sensorineural hearing loss dividing into three groups: 43 subjects were fitted with digital, 15 with programmable, 32 with analog hearing aids. After pure tone audiometry, Abbreviated profile of hearing aid benefit (APHAB was completed before and one month after using hearing aids to determine the benefit of them. Results: Global APHAB mean scores for digital, programmable and analog hearing aids were 49.05, 33.19 and 39.53, respectively. Ease of Communication subscale mean scores were 53.46 for digitals, 37.66 for programmables and 39.09 for analogs. Background noise subscale mean scores for digital programmable and analog hearing aids were 46.36, 25.53 and 35.31, respectively. Global and also both subscale mean scores showed significant difference between digital hearing aids and programmable and analog ones. There was no significant difference between reverberation subscale mean scores of three groups. Conclusion: It seems digital hearing aids may be more beneficial to reduce disability caused by hearing loss than analog and programmable hearing aids are.

  13. Hearing aid fine-tuning based on Dutch descriptions.

    Science.gov (United States)

    Thielemans, Thijs; Pans, Donné; Chenault, Michelene; Anteunis, Lucien

    2017-07-01

    The aim of this study was to derive an independent fitting assistant based on expert consensus. Two questions were asked: (1) what (Dutch) terms do hearing impaired listeners use nowadays to describe their specific hearing aid fitting problems? (2) What is the expert consensus on how to resolve these complaints by adjusting hearing aid parameters? Hearing aid dispensers provided descriptors that impaired listeners use to describe their reactions to specific hearing aid fitting problems. Hearing aid fitting experts were asked "How would you adjust the hearing aid if its user reports that the aid sounds…?" with the blank filled with each of the 40 most frequently mentioned descriptors. 112 hearing aid dispensers and 15 hearing aid experts. The expert solution with the highest weight value was considered the best solution for that descriptor. Principal component analysis (PCA) was performed to identify a factor structure in fitting problems. Nine fitting problems could be identified resulting in an expert-based, hearing aid manufacturer independent, fine-tuning fitting assistant for clinical use. The construction of an expert-based, hearing aid manufacturer independent, fine-tuning fitting assistant to be used as an additional tool in the iterative fitting process is feasible.

  14. The Effects of Hearing Aid Directional Microphone and Noise Reduction Processing on Listening Effort in Older Adults with Hearing Loss.

    Science.gov (United States)

    Desjardins, Jamie L

    2016-01-01

    Older listeners with hearing loss may exert more cognitive resources to maintain a level of listening performance similar to that of younger listeners with normal hearing. Unfortunately, this increase in cognitive load, which is often conceptualized as increased listening effort, may come at the cost of cognitive processing resources that might otherwise be available for other tasks. The purpose of this study was to evaluate the independent and combined effects of a hearing aid directional microphone and a noise reduction (NR) algorithm on reducing the listening effort older listeners with hearing loss expend on a speech-in-noise task. Participants were fitted with study worn commercially available behind-the-ear hearing aids. Listening effort on a sentence recognition in noise task was measured using an objective auditory-visual dual-task paradigm. The primary task required participants to repeat sentences presented in quiet and in a four-talker babble. The secondary task was a digital visual pursuit rotor-tracking test, for which participants were instructed to use a computer mouse to track a moving target around an ellipse that was displayed on a computer screen. Each of the two tasks was presented separately and concurrently at a fixed overall speech recognition performance level of 50% correct with and without the directional microphone and/or the NR algorithm activated in the hearing aids. In addition, participants reported how effortful it was to listen to the sentences in quiet and in background noise in the different hearing aid listening conditions. Fifteen older listeners with mild sloping to severe sensorineural hearing loss participated in this study. Listening effort in background noise was significantly reduced with the directional microphones activated in the hearing aids. However, there was no significant change in listening effort with the hearing aid NR algorithm compared to no noise processing. Correlation analysis between objective and self

  15. Autonomous motivation is associated with hearing aid adoption.

    Science.gov (United States)

    Ridgway, Jason; Hickson, Louise; Lind, Christopher

    2015-07-01

    To use the self-determination theory of motivation to investigate whether different forms of motivation were associated with adults' decisions whether or not to adopt hearing aids. A quantitative approach was used in this cohort study. Participants completed the treatment self-regulation questionnaire (TSRQ), which measured autonomous and controlled motivation for hearing aid adoption. Sociodemographic data and audiometric information were also obtained. Participants were 253 adults who had sought information about their hearing but had not consulted with a hearing professional. Participants were categorized as hearing aid adopters if they had been fitted with hearing aids 4-6 months after completing the TSRQ, and as non-adopters if they had not. Multivariate logistic regression was used to examine associations between autonomous and controlled motivation, sociodemographic and audiometric variables, and hearing aid adoption (n = 160). Three factors were significantly associated with increased hearing aid adoption when the influence of other variables was accounted for: autonomous motivation, perceived hearing difficulty, and poorer hearing. Controlled motivation was not found to influence hearing aid adoption. These empirical findings that link autonomous motivation to decisions of hearing help-seekers have implications for the ways practitioners may evaluate motivation and could inform discussions with clients about hearing aid adoption.

  16. Interventions to improve hearing aid use in adult auditory rehabilitation.

    Science.gov (United States)

    Barker, Fiona; Mackenzie, Emma; Elliott, Lynette; Jones, Simon; de Lusignan, Simon

    2016-08-18

    Acquired adult-onset hearing loss is a common long-term condition for which the most common intervention is hearing aid fitting. However, up to 40% of people fitted with a hearing aid either fail to use it or may not gain optimal benefit from it. This is an update of a review first published in The Cochrane Library in 2014. To assess the long-term effectiveness of interventions to promote the use of hearing aids in adults with acquired hearing loss fitted with at least one hearing aid. The Cochrane ENT Information Specialist searched the Cochrane ENT Trials Register; Central Register of Controlled Trials (CENTRAL 2016, Issue 5); PubMed; EMBASE; CINAHL; Web of Science; ClinicalTrials.gov; ICTRP and additional sources for published and unpublished trials. The date of the search was 13 June 2016. We included randomised controlled trials (RCTs) of interventions designed to improve or promote hearing aid use in adults with acquired hearing loss compared with usual care or another intervention. We excluded interventions that compared hearing aid technology. We classified interventions according to the 'chronic care model' (CCM). The primary outcomes were hearing aid use (measured as adherence or daily hours of use) and adverse effects (inappropriate advice or clinical practice, or patient complaints). Secondary patient-reported outcomes included quality of life, hearing handicap, hearing aid benefit and communication. Outcomes were measured over the short ( 12 to quality of evidence to be very low or low for the primary outcomes where data were available.The majority of participants were over 65 years of age with mild to moderate adult-onset hearing loss. There was a mix of new and experienced hearing aid users. Six of the studies (287 participants) assessed long-term outcomes.All 37 studies tested interventions that could be classified using the CCM as self-management support (ways to help someone to manage their hearing loss and hearing aid(s) better by giving

  17. Pediatric hearing aid use: parent-reported challenges.

    Science.gov (United States)

    Muñoz, Karen; Olson, Whitney A; Twohig, Michael P; Preston, Elizabeth; Blaiser, Kristina; White, Karl R

    2015-01-01

    The aim of this study was to investigate parent-reported challenges related to hearing aid management and parental psychosocial characteristics during the first 3 years of the child's life. Using a cross-sectional survey design, surveys were distributed to parents of children with hearing loss via state Early Intervention programs in Utah and Indiana. Packets contained one family demographic form and two sets of three questionnaires to obtain responses from mothers and fathers separately: the Parent Hearing Aid Management Inventory explored parent access to information, parent confidence in performing skills, expectations, communication with the audiologist, and hearing aid use challenges. The Acceptance and Action Questionnaire measured psychological flexibility, experiential avoidance, and internal thought processes that can affect problem-solving ability and decrease an individual's ability to take value-based actions. The Patient Health Questionnaire identified symptoms of depression. Thirty-seven families completed questionnaires (35 mothers and 20 fathers). Most responses were parents of toddlers (M = 22 months) who had been wearing binaural hearing aids for an average of 15 months. Both mothers and fathers reported that even though the amount of information they received was overwhelming, most (84%) preferred to have all the information at the beginning, rather than to receive it over an extended time period. Parents reported an array of challenges related to hearing aid management, with the majority related to daily management, hearing aid use, and emotional adjustment. Sixty-six percent of parents reported an audiologist taught them how to complete a listening check using a stethoscope, however, only one-third reported doing a daily hearing aid listening check. Both mothers and fathers reported a wide range of variability in their confidence in performing activities related to hearing aid management, and most reported minimal confidence in their ability to

  18. Hearing Aid with Visual Indicator

    DEFF Research Database (Denmark)

    2004-01-01

    The invention comprises a hearing aid, which has a casing containing a signal receiving part for receiving an audio signal, an audio transducer for providing an audio signal to the user, a signal transmission path between the signal receiving part and the audio transducer, whereby a battery...... is provided for powering the signal receiving part, the signal path and the audio transducer, and where further means are provided for assessing the function of the hearing aid and for generating an electrical indication signal which indicates the function of the hearing aid and where further means...... are provided for intermittently generating a power signal in response to the electrical indication signal and where means are provided for converting the power signal into a light signal, such that the light signal is visible from outside the hearing aid....

  19. Investigation of internal feedback in hearing aids

    DEFF Research Database (Denmark)

    Friis, Lars

    2009-01-01

    with vibroacoustic transmission from the receiver to the microphones often occur during the use of hearing aids. This transmission causes feedback at certain critical gain levels where it produces a loud uncomfortable squealing. Consequently feedback often constitutes the limiting factor for the maximum obtainable...... gain in the hearing aid and it therefore represents a critical design problem. Feedback in hearing aids is usually divided into external and internal feedback. External feedback is caused by the leakage of sound from the ear canal whereas internal feedback is due to transmission of sound and vibrations...... internally in the hearing aid. As a result of reducing the size of hearing aids, manufacturers have experienced an increase in internal feedback problems. The main objective of the present thesis is therefore to examine the vibroacoustic mechanisms responsible for internal feedback in hearing aids...

  20. Better together: reduced compliance after sequential versus simultaneous bilateral hearing aids fitting.

    Science.gov (United States)

    Lavie, Limor; Banai, Karen; Attias, Joseph; Karni, Avi

    2014-03-01

    The purpose of this study was to determine the effects of sequential versus simultaneous bilateral hearing aids fitting on patient compliance. Thirty-six older adults with hearing impairment participated in this study. Twelve were fitted with bilateral hearing aids simultaneously. The remaining participants were fitted sequentially: One hearing aid (to the left or to the right ear) was used initially; 1 month later, the other ear was also fitted with a hearing aid for bilateral use. Self-reports on usefulness and compliance were elicited after the first and second months of hearing aid use. In addition, the number of hours the hearing aids were used was extracted from the data loggings of each device. Simultaneous fitting resulted in high levels of compliance and consistent usage throughout the study period. Sequential fitting resulted in abrupt reduction in compliance and hours of use once the second hearing aid was added, both in the clinical scoring and in the data loggings. Simultaneous fitting of bilateral hearing aids results in better compliance compared with sequential fitting. The addition of a second hearing aid after a relatively short period of monaural use may lead to inconsistent use of both hearing aids.

  1. [Effect of rehabilitation for prelingual deaf children who use cochlear implants in conjunction with hearing aids in the opposite ears].

    Science.gov (United States)

    Tian, Yanjing; Zhou, Huifang; Zhang, Jing; Yang, Dong; Xu, Yi; Guo, Yuxi

    2012-10-01

    To compare the effect of rehabilitation of prelingual deaf children who used a cochlear implant (CI) in one ear and a hearing aids in the opposite ear while the hearing level of the opposite ears are different. Hearing ability, language ability and learning ability was included in the content. The aim of this research is to investigate better style of rehabilitation, and to offer the best help to the prelingual deaf children. Accord ing to the hearing level of the ear opposite to the one wearing a cochlear implant and whether the opposite ear wear a hearing aid or not, 30 prelingual deaf children were divided into three groups, including cochlear implant with opposite severe hearing loss and hearing aid ear (CI+SHA), cochlear implant with opposite profound hearing loss and hearing aid ear (CI+PHA), cochlear implant only (CI). The effect of rehabilitation was assessed in six different times (3,6,9,12,15 and 18 months after the cochlear implants and hearing aids began to work). The longer time the rehabilitation spends, the better the hearing ability,language ability and the learning ability were. The hearing ability of CI+SHA was better than those of CI+PHA (Pdeaf children should take much more time on rehabilitation. The effect of rehabilitation for prelingual deaf children who used cochlear implant in one ear and hearing aid in the other depend on the residual hearing level of the other ear. If a prelingual deaf children still has any residual hearing level in the ear opposite to the cochlear implant ear, it is better for him/her to wear a hearing aid in the ear.

  2. Hearing aid fitting for visual and hearing impaired patients with Usher syndrome type IIa.

    Science.gov (United States)

    Hartel, B P; Agterberg, M J H; Snik, A F; Kunst, H P M; van Opstal, A J; Bosman, A J; Pennings, R J E

    2017-08-01

    Usher syndrome is the leading cause of hereditary deaf-blindness. Most patients with Usher syndrome type IIa start using hearing aids from a young age. A serious complaint refers to interference between sound localisation abilities and adaptive sound processing (compression), as present in today's hearing aids. The aim of this study was to investigate the effect of advanced signal processing on binaural hearing, including sound localisation. In this prospective study, patients were fitted with hearing aids with a nonlinear (compression) and linear amplification programs. Data logging was used to objectively evaluate the use of either program. Performance was evaluated with a speech-in-noise test, a sound localisation test and two questionnaires focussing on self-reported benefit. Data logging confirmed that the reported use of hearing aids was high. The linear program was used significantly more often (average use: 77%) than the nonlinear program (average use: 17%). The results for speech intelligibility in noise and sound localisation did not show a significant difference between type of amplification. However, the self-reported outcomes showed higher scores on 'ease of communication' and overall benefit, and significant lower scores on disability for the new hearing aids when compared to their previous hearing aids with compression amplification. Patients with Usher syndrome type IIa prefer a linear amplification over nonlinear amplification when fitted with novel hearing aids. Apart from a significantly higher logged use, no difference in speech in noise and sound localisation was observed between linear and nonlinear amplification with the currently used tests. Further research is needed to evaluate the reasons behind the preference for the linear settings. © 2016 The Authors. Clinical Otolaryngology Published by John Wiley & Sons Ltd.

  3. The Effects of Unilateral Adaptation of Hearing Aids on Symptoms of Depression and Social Activity Constraints of Elderly

    Directory of Open Access Journals (Sweden)

    Santos, Fernanda Dutra dos

    2015-01-01

    Full Text Available Introduction Hearing loss is one of the most common problems in the elderly population. Besides compromising oral communication, it directly affects social relations and prevents elderly patients from living actively in society, possibly leading to the onset of depression or other conditions. Objective To analyze the effects of unilateral adaptation of hearing aids on symptoms of depression and the social activity constraints of elderly subjects with hearing impairment. Methods The sample consisted of elderly subjects with hearing loss who did not use hearing aids. Data were collected in two phases. Initially, all participants underwent an audiological assessment and answered the Hearing Handicap Inventory for Elderly (summarized version and the Geriatric Depression Scale. All subjects participated in the selection and hearing aid adaptation processes and became monaural hearing aid users. After 30 days of hearing aid use, they were assessed with the same instruments. The results of the questionnaires before and after hearing aid adaptation were compared. Results The sample consisted of 13 individuals, between 60 and 90 years old (mean 72.85 ± 11.05 years. Data analysis showed that there was significant improvement in social activity constraints (p < 0.001 and in symptoms of depression (p = 0.031. Conclusion Results show that, in the sample studied, unilateral hearing aid adaptation reduced social activity constraints and depression symptoms.

  4. Hearing aids for otitis media with effusion: Do children use them?

    Science.gov (United States)

    Gan, Richard Wei Chern; Overton, Parisa; Benton, Claire; Daniel, Matija

    2017-08-01

    ENT surgeons may refer children with otitis media with effusion (OME) to audiology for consideration of hearing aids. They are an option for the treatment of OME, but are only effective if the child actually wears them. Our study investigated what proportion of children referred for hearing aids actually receive them, and whether children use them. Retrospective study of children referred to audiology from November 2013 to August 2014, including 70 children referred by ENT for hearing aids for OME, plus a further 5 children with OME given hearing aids through direct access audiology service. During the study period, there were 202 referrals of children to audiology, of which 70 (34.7%) were for consideration of hearing aids for OME. Of these 70 referred children, 37 (52.9%) were not fitted with hearing aids due to normal audiometry (23), asymptomatic mild hearing loss (7), nonattendance (3), clinical decision to just monitor hearing (1), parental decline (2), and unrecorded reason (1). A total of 38 children (including direct access patients) were fitted with hearing aids for OME. Majority (36/38) of children issued aids used them, 16 all day, 7 only at school, 1 only at home, 3 only when needed, and 9 used them for an unspecified duration; 1 child's use of hearing aids was unrecorded, and 1 child refused to use it. 21 were fitted bilaterally and 17 unilaterally. 37 were behind the ear aids and 1 a BAHA softband. A third of referrals to paediatric audiology by ENT are for consideration of hearing aids for OME. Only about half of children referred to audiology for hearing aids for OME actually receive them, as by the time they see audiology the hearing loss has frequently resolved or is asymptomatic so that aiding is unwarranted. Once fitted, they appear to be well accepted. Hearing aids have fair utilization in children fitted with them for OME. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Hearing aid user guides: suitability for older adults.

    Science.gov (United States)

    Caposecco, Andrea; Hickson, Louise; Meyer, Carly

    2014-02-01

    The aim of this study was to analyse the content, design, and readability of printed hearing aid user guides to determine their suitability for older adults, who are the main users of hearing aids. Hearing aid user guides were assessed using four readability formulae and a standardized tool to assess content and design (SAM - Suitability Assessment of Materials). A sample of 36 hearing aid user guides (four user guides from nine different hearing aid manufacturers) were analysed. Sixty nine percent of user guides were rated 'not suitable' and 31% were rated 'adequate' for their suitability. Many scored poorly for scope, vocabulary, aspects of layout and typography, and learning stimulation and motivation. The mean reading grade level for all user guides was grade 9.6 which is too high for older adults. The content, design, and readability of hearing aid user guides are not optimal for older adults and thus may serve as a barrier to successful hearing aid outcomes for this population.

  6. Introduction to audiology: Some basics about hearing loss, hearing technologies and barriers to hearing aid use

    DEFF Research Database (Denmark)

    Mourtou, Eleni; Meis, Markus

    2012-01-01

    This chapter provides background information for researchers who wish to become familiar with some basic medical and audiological aspects of hearing loss and the technology of hearing aids. It introduces (1) the disciplines involved in research on hearing loss, (2) the medical categories of hearing...... loss and their various effects on communication, (3) the different degrees of hearing loss as defined by different national and international organizations, (4) statistics on the preva- lence of hearing loss worldwide, (5) some technological aspects of hearing instruments, (6) sta- tistics on non...

  7. Hearing Aid Fitting: Monaural vs. Binaural

    Directory of Open Access Journals (Sweden)

    Ahmad Keshani

    2002-07-01

    Full Text Available One of the most important issue for selecting and fitting of hearing aids that should receive special attention is binaural amplification. According to several investigations, superiority of binaural amplification on monaural one is confirmed. Binaural Amplification may have considerable effects on fromation and developing of superior dimensions of hearing including: Localization, Binaural squelch (Better hearing in presence of noise. So, it is necessary to know the basic and scientific concepts and applicable principles of binaural hearing and binaural fitting. Present paper deals with this important subject.

  8. The influence of hearing aids on the speech and language development of children with hearing loss.

    Science.gov (United States)

    Tomblin, J Bruce; Oleson, Jacob J; Ambrose, Sophie E; Walker, Elizabeth; Moeller, Mary Pat

    2014-05-01

    IMPORTANCE Hearing loss (HL) in children can be deleterious to their speech and language development. The standard of practice has been early provision of hearing aids (HAs) to moderate these effects; however, there have been few empirical studies evaluating the effectiveness of this practice on speech and language development among children with mild-to-severe HL. OBJECTIVE To investigate the contributions of aided hearing and duration of HA use to speech and language outcomes in children with mild-to-severe HL. DESIGN, SETTING, AND PARTICIPANTS An observational cross-sectional design was used to examine the association of aided hearing levels and length of HA use with levels of speech and language outcomes. One hundred eighty 3- and 5-year-old children with HL were recruited through records of Universal Newborn Hearing Screening and referrals from clinical service providers in the general community in 6 US states. INTERVENTIONS All but 4 children had been fitted with HAs, and measures of aided hearing and the duration of HA use were obtained. MAIN OUTCOMES AND MEASURES Standardized measures of speech and language ability were obtained. RESULTS Measures of the gain in hearing ability for speech provided by the HA were significantly correlated with levels of speech (ρ179 = 0.20; P = .008) and language: ρ155 = 0.21; P = .01) ability. These correlations were indicative of modest levels of association between aided hearing and speech and language outcomes. These benefits were found for children with mild and moderate-to-severe HL. In addition, the amount of benefit from aided hearing interacted with the duration of HA experience (Speech: F4,161 = 4.98; P < .001; Language: F4,138 = 2.91; P < .02). Longer duration of HA experience was most beneficial for children who had the best aided hearing. CONCLUSIONS AND RELEVANCE The degree of improved hearing provided by HAs was associated with better speech and language development in children

  9. Personality and the subjective assessment of hearing aids.

    Science.gov (United States)

    Cox, R M; Alexander, G C; Gray, G

    1999-01-01

    Relatively little is known about the influence of patients' personality features on the responses they make to self-assessment items used to measure the outcome of a hearing aid fitting. If the personality of the hearing aid wearer has a significant influence on self-report outcome data, it would be important to explore the relevant personality variables and to be cognizant of their effects when using subjective outcome data to justify decisions about clinical services or other matters. This investigation explored the relationship between several personality attributes and responses to the Abbreviated Profile of Hearing Aid Benefit (APHAB). It found that more extroverted patients tend to report more hearing aid benefit in all speech communication situations. In addition, patients with a more external locus of control tend to have more negative reactions to loud environmental sounds, both with and without amplification. Anxiety also played a small additional role in determining APHAB responses. Although personality variables were found to explain a relatively small amount of the variance in APHAB responses (usually around 10%), these outcomes should alert practitioners and researchers to the potential effects of personality variables in all self-report data.

  10. Efficient individualization of hearing aid processed sound

    DEFF Research Database (Denmark)

    Nielsen, Jens Brehm; Nielsen, Jakob

    2013-01-01

    Due to the large amount of options offered by the vast number of adjustable parameters in modern digital hearing aids, it is becoming increasingly daunting—even for a fine-tuning professional—to perform parameter fine tuning to satisfactorily meet the preference of the hearing aid user. In addition......, the communication between the fine-tuning professional and the hearing aid user might muddle the task. In the present paper, an interactive system is proposed to ease and speed up fine tuning of hearing aids to suit the preference of the individual user. The system simultaneously makes the user conscious of his own...... preferences while the system itself learns the user’s preference. Since the learning is based on probabilistic modeling concepts, the system handles inconsistent user feedback efficiently. Experiments with hearing impaired subjects show that the system quickly discovers individual preferred hearing...

  11. Elderly With Different Types of Hearing Loss and Comorbidities: Satisfaction With Hearing Aids

    Directory of Open Access Journals (Sweden)

    Dashti

    2015-07-01

    Full Text Available Background Hearing loss is developing when age is rising. Initiation and progression rates of hearing loss vary among different individuals and groups. Objectives The current study aimed to determine satisfaction of the elderly with their hearing aids in different types of hearing loss and comorbidities. Patients and Methods The study was conducted on 40 elderly subjects suffering from hearing loss and using hearing aids. The data collection method included assessment of hearing loss in addition to using a questionnaire to estimate respondents' satisfaction with their hearing aids in daily life. The Persian version of the Satisfaction with Amplification in Daily Life (SADL questionnaire was administered. The data were analyzed using descriptive and inferential statistics by SPSS software version19. Results The mean satisfaction scores of the elderly were 4.83 ± 0.51 and 5.36 ± 0.30 in the sensorineural loss groups. There was no significant difference between different comorbidities. There was a significant difference between satisfaction level of cost and services subscales in the symmetrical styles of hearing loss (P value = 0.04. Conclusions The findings of the study indicated a high satisfaction of the elderly with their hearing aids, considering the type of hearing loss. Despite all the efforts to improve the audiologic services during verification process, the elderly should be consulted specifically in order to fit their hearing aid as well as their expectations from aid.

  12. Consumer Preferences for Hearing Aid Attributes

    Science.gov (United States)

    Lataille, Angela T.; Buttorff, Christine; White, Sharon; Niparko, John K.

    2012-01-01

    Low utilization of hearing aids has drawn increased attention to the study of consumer preferences using both simple ratings (e.g., Likert scale) and conjoint analyses, but these two approaches often produce inconsistent results. The study aims to directly compare Likert scales and conjoint analysis in identifying important attributes associated with hearing aids among those with hearing loss. Seven attributes of hearing aids were identified through qualitative research: performance in quiet settings, comfort, feedback, frequency of battery replacement, purchase price, water and sweat resistance, and performance in noisy settings. The preferences of 75 outpatients with hearing loss were measured with both a 5-point Likert scale and with 8 paired-comparison conjoint tasks (the latter being analyzed using OLS [ordinary least squares] and logistic regression). Results were compared by examining implied willingness-to-pay and Pearson’s Rho. A total of 56 respondents (75%) provided complete responses. Two thirds of respondents were male, most had sensorineural hearing loss, and most were older than 50; 44% of respondents had never used a hearing aid. Both methods identified improved performance in noisy settings as the most valued attribute. Respondents were twice as likely to buy a hearing aid with better functionality in noisy environments (p < .001), and willingness to pay for this attribute ranged from US$2674 on the Likert to US$9000 in the conjoint analysis. The authors find a high level of concordance between the methods—a result that is in stark contrast with previous research. The authors conclude that their result stems from constraining the levels on the Likert scale. PMID:22514094

  13. Auditory and language skills of children using hearing aids

    Directory of Open Access Journals (Sweden)

    Leticia Macedo Penna

    2015-04-01

    Full Text Available INTRODUCTION: Hearing loss may impair the development of a child. The rehabilitation process for individuals with hearing loss depends on effective interventions.OBJECTIVE: To describe the linguistic profile and the hearing skills of children using hearing aids, to characterize the rehabilitation process and to analyze its association with the children's degree of hearing loss.METHODS: Cross-sectional study with a non-probabilistic sample of 110 children using hearing aids (6-10 years of age for mild to profound hearing loss. Tests of language, speech perception, phonemic discrimination, and school performance were performed. The associations were verified by the following tests: chi-squared for linear trend and Kruskal-Wallis.RESULTS: About 65% of the children had altered vocabulary, whereas 89% and 94% had altered phonology and inferior school performance, respectively. The degree of hearing loss was associated with differences in the median age of diagnosis; the age at which the hearing aids were adapted and at which speech therapy was started; and the performance on auditory tests and the type of communication used.CONCLUSION: The diagnosis of hearing loss and the clinical interventions occurred late, contributing to impairments in auditory and language development.

  14. The effectiveness of linguistic plays on the grammatical skills of hearing-impaired children with hearing aids

    Directory of Open Access Journals (Sweden)

    Sahar Mohammad Esmaeilzadeh

    2014-12-01

    Full Text Available Background and Aim: Grammatical skills development of hearing-impaired children depends on using appropriate educational rehabilitation programs. This study aims to investigate the effectiveness of linguistic plays on the grammatical skills in hearing-impaired children with hearing aids.Methods: Ten hearing-impaired children with hearing aids, aged between 5 and 7, were randomly assigned to two groups (5 children in each group. Each treatment group received 12 sessions on linguistic plays. The grammatical skills of these children were evaluated via the TOLD-P: 3 (Persian version; in addition, their level of intelligence was assessed by the Raven test.Results: The difference between the scores of both control and treatment groups revealed a statistically significant difference in grammatical skills (t=7.61, p=0.001 and three subskills of the children who participated in the linguistic plays. These subskills include syntactic understanding (t=3.16, p=0.013, sentence imitation (t=1.71, p=0.006, and morphological completion (t=6.55, p=0.001. In other words, the findings suggest that linguistic plays have a significant impact on the improvement of the aforementioned skills in hearing-impaired children.Conclusion: Results suggest that it would be beneficial to include linguistic plays as part of routine rehabilitation programs as a means of improving the grammatical difficulties of children. After partaking in linguistic plays, children significantly improved their ability to comprehend the meaning of sentences and also to recognize, understand, and use common Persian morphological forms.

  15. Hearing aid-related satisfaction based on type and degree of hearing loss in elderly

    Directory of Open Access Journals (Sweden)

    Farzad FarajiKhiavi

    2015-02-01

    Full Text Available Background and Aim: Hearing loss is one of the most prevalent chronic diseases in the elderly; using a hearing aid to alleviate auditory impairment can positively affect their quality of life. This research aimed to determine the level of satisfaction concerning hearing aids in elderly people with hearing impairment based on the type and degree of hearing loss.Methods: An analytic cross-sectional research design was used ; the sample included 40 elderly people who used hearing aids. According to the World Health Organization (WHO age classification, participants were divided into two age groups: 65-74 years (n=20 and 75-90 years (n=20. Satisfaction levels were assessed using a standard satisfaction with amplification in daily life (SADL questionnaire.Results: Satisfaction levels in the 65-74 age group were significantly higher than that in the 75-90 age group (p=0.02. Participants with mixed hearing loss revealed higher satisfaction levels than participants with sensorineural hearing loss (p=0.02. On the negative effects dimension, participants with severe hearing loss exhibited significantly higher satisfaction levels than participants with moderate or moderate to severe hearing loss (p=0.01.Conclusion: Total satisfaction mean scores were relatively high in the elderly participants . Negative features could be reduced via careful consultation regarding the aids’ amplifying capabilities and limitations in groups with moderate or moderate to severe hearing loss.

  16. Hearing Aids: MedlinePlus Health Topic

    Science.gov (United States)

    ... for hearing loss (Medical Encyclopedia) Also in Spanish Topic Image MedlinePlus Email Updates Get Hearing Aids updates ... MEDICAL ENCYCLOPEDIA Devices for hearing loss Related Health Topics Cochlear Implants Hearing Disorders and Deafness National Institutes ...

  17. Types of Hearing Aids

    Science.gov (United States)

    ... aids : Most parts are contained in a small plastic case that rests behind the ear; the case ... certain situations (for example, background noise and whistle reduction). They also have greater flexibility in hearing aid ...

  18. State of the art in perceptual design of hearing aids

    Science.gov (United States)

    Edwards, Brent W.; van Tasell, Dianne J.

    2002-05-01

    Hearing aid capabilities have increased dramatically over the past six years, in large part due to the development of small, low-power digital signal processing chips suitable for hearing aid applications. As hearing aid signal processing capabilities increase, there will be new opportunities to apply perceptually based knowledge to technological development. Most hearing loss compensation techniques in today's hearing aids are based on simple estimates of audibility and loudness. As our understanding of the psychoacoustical and physiological characteristics of sensorineural hearing loss improves, the result should be improved design of hearing aids and fitting methods. The state of the art in hearing aids will be reviewed, including form factors, user requirements, and technology that improves speech intelligibility, sound quality, and functionality. General areas of auditory perception that remain unaddressed by current hearing aid technology will be discussed.

  19. Exploring the influence of culture on hearing help-seeking and hearing-aid uptake.

    Science.gov (United States)

    Zhao, Fei; Manchaiah, Vinaya; St Claire, Lindsay; Danermark, Berth; Jones, Lesley; Brandreth, Marian; Krishna, Rajalakshmi; Goodwin, Robin

    2015-07-01

    The purpose of this paper was to highlight the importance of cultural influence in understanding hearing-help seeking and hearing-aid uptake. Information on audiological services in different countries and 'theories related to cross-culture' is presented, followed by a general discussion. Twenty-seven relevant literature reviews on hearing impairment, cross-cultural studies, and the health psychology model and others as secondary resources. Despite the adverse consequences of hearing impairment and the significant potential benefits of audiological rehabilitation, only a small number of those with hearing impairment seek professional help and take up appropriate rehabilitation. Therefore, hearing help-seeking and hearing-aid uptake has recently become the hot topic for clinicians and researchers. Previous research has identified many contributing factors for hearing help-seeking with self-reported hearing disability being one of the main factors. Although significant differences in help-seeking and hearing-aid adoption rates have been reported across countries in population studies, limited literature on the influence of cross-cultural factors in this area calls for an immediate need for research. This paper highlights the importance of psychological models and cross-cultural research in the area of hearing help-seeking and hearing-aid uptake, and consequently some directions for future research are proposed.

  20. Hearing aids' electromagnetic immunity to environmental RF fields

    International Nuclear Information System (INIS)

    Facta, S.; Benedetto, A.; Anglesio, L.; D'Amore, G.

    2004-01-01

    In this work, the electromagnetic interference on hearing aids was evaluated. Electromagnetic (EM) immunity tests on different types of hearing aids were carried out, using signals of intensity and modulation comparable to those present in the environment. The purpose of this work is to characterise the interference, establishing the immunity threshold for different frequencies and finding out which types of hearing aids are more susceptible, and in which frequency range. The tests were carried out in a GTEM cell on seven hearing aids, using AM and GSM signals in the radiofrequency (RF) range. (authors)

  1. Gaze Patterns in Auditory-Visual Perception of Emotion by Children with Hearing Aids and Hearing Children

    Directory of Open Access Journals (Sweden)

    Yifang Wang

    2017-12-01

    Full Text Available This study investigated eye-movement patterns during emotion perception for children with hearing aids and hearing children. Seventy-eight participants aged from 3 to 7 were asked to watch videos with a facial expression followed by an oral statement, and these two cues were either congruent or incongruent in emotional valence. Results showed that while hearing children paid more attention to the upper part of the face, children with hearing aids paid more attention to the lower part of the face after the oral statement was presented, especially for the neutral facial expression/neutral oral statement condition. These results suggest that children with hearing aids have an altered eye contact pattern with others and a difficulty in matching visual and voice cues in emotion perception. The negative cause and effect of these gaze patterns should be avoided in earlier rehabilitation for hearing-impaired children with assistive devices.

  2. Beamforming under Quantization Errors in Wireless Binaural Hearing Aids

    Directory of Open Access Journals (Sweden)

    Srinivasan Sriram

    2008-01-01

    Full Text Available Improving the intelligibility of speech in different environments is one of the main objectives of hearing aid signal processing algorithms. Hearing aids typically employ beamforming techniques using multiple microphones for this task. In this paper, we discuss a binaural beamforming scheme that uses signals from the hearing aids worn on both the left and right ears. Specifically, we analyze the effect of a low bit rate wireless communication link between the left and right hearing aids on the performance of the beamformer. The scheme is comprised of a generalized sidelobe canceller (GSC that has two inputs: observations from one ear, and quantized observations from the other ear, and whose output is an estimate of the desired signal. We analyze the performance of this scheme in the presence of a localized interferer as a function of the communication bit rate using the resultant mean-squared error as the signal distortion measure.

  3. Beamforming under Quantization Errors in Wireless Binaural Hearing Aids

    Directory of Open Access Journals (Sweden)

    Kees Janse

    2008-09-01

    Full Text Available Improving the intelligibility of speech in different environments is one of the main objectives of hearing aid signal processing algorithms. Hearing aids typically employ beamforming techniques using multiple microphones for this task. In this paper, we discuss a binaural beamforming scheme that uses signals from the hearing aids worn on both the left and right ears. Specifically, we analyze the effect of a low bit rate wireless communication link between the left and right hearing aids on the performance of the beamformer. The scheme is comprised of a generalized sidelobe canceller (GSC that has two inputs: observations from one ear, and quantized observations from the other ear, and whose output is an estimate of the desired signal. We analyze the performance of this scheme in the presence of a localized interferer as a function of the communication bit rate using the resultant mean-squared error as the signal distortion measure.

  4. Role of hearing AIDS in tinnitus intervention: a scoping review.

    Science.gov (United States)

    Shekhawat, Giriraj Singh; Searchfield, Grant D; Stinear, Cathy M

    2013-09-01

    Tinnitus can have a devastating impact on the quality of life of the sufferer. Although the mechanisms underpinning tinnitus remain uncertain, hearing loss is often associated with its onset, and hearing aids are among the most commonly used tools for its management. To conduct a scoping review to explore the role of hearing aids in tinnitus management. Scoping review based on the six-stage framework of Arksey and O'Malley (2005). Relevant studies were identified using various databases (Scopus, Google Scholar, SpringerLink, and PubMed) and hand searching of journals and a reference list of articles. Out of 277 shortlisted articles, 29 studies (18 research studies and 11 reviews) were chosen for charting of data based on their abstracts. Tinnitus assessment measures used in studies were recorded along with changes in their scores. Measures used in studies included the Tinnitus Handicap Inventory (THI), Tinnitus Handicap Questionnaire (THQ), Tinnitus Severity Index (TSI), Tinnitus Reaction Questionnaire (TRQ), German version of Tinnitus Questionnaire (TQ), Beck Depression Inventory (BDI), and visual analogue scale (VAS) of tinnitus intensity. Where possible Cohen's d effect size statistic was calculated. Although the quality of evidence for hearing aids' effect on tinnitus is not strong, the weight of evidence (17 research studies for, 1 against) suggests merit in using hearing aids for tinnitus management. The majority of studies reviewed support the use of hearing aids for tinnitus management. Clinicians should feel reassured that some evidence shows support for the use of hearing aids for treating tinnitus, but there is still a need for stronger methodology and randomized control trials. American Academy of Audiology.

  5. Understanding the low uptake of bone-anchored hearing aids: a review.

    Science.gov (United States)

    Powell, R; Wearden, A; Pardesi, S M; Green, K

    2017-03-01

    Bone-anchored hearing aids improve hearing for patients for whom conventional behind-the-ear aids are problematic. However, uptake of bone-anchored hearing aids is low and it is important to understand why this is the case. A narrative review was conducted. Studies examining why people accept or decline bone-anchored hearing aids and satisfaction levels of people with bone-anchored hearing aids were reviewed. Reasons for declining bone-anchored hearing aids included limited perceived benefits, concerns about surgery, aesthetic concerns and treatment cost. No studies providing in-depth analysis of the reasons for declining or accepting bone-anchored hearing aids were identified. Studies of patient satisfaction showed that most participants reported benefits with bone-anchored hearing aids. However, most studies used cross-sectional and/or retrospective designs and only included people with bone-anchored hearing aids. Important avenues for further research are in-depth qualitative research designed to fully understand the decision-making process for bone-anchored hearing aids and rigorous quantitative research comparing satisfaction of people who receive bone-anchored hearing aids with those who receive alternative (or no) treatments.

  6. Self-Assessment of Hearing and Purchase of Hearing Aids by Middle-Aged and Elderly Adults

    Directory of Open Access Journals (Sweden)

    Otavio, Andressa Colares da Costa

    2015-06-01

    Full Text Available Introduction Presbycusis is a consequence of aging. Prescription of hearing aids is part of the treatment, although the prevalence of use by elderly people is still small. Objective To verify whether or not self-assessment of hearing is a predictor for purchase of hearing aids. Methods Quantitative, cross-sectional, descriptive, and observational study. Participants were subjects who sought a private hearing center for selection of hearing aids. During the diagnostic interview, subjects answered the following question: “On a scale of 1 to 10, with 1 being the worst and 10 the best, how would you rate your overall hearing ability?” After that, subjects underwent audiometry, selected a hearing aid, performed a home trial, and decided whether or not to purchase the hearing aid. The variables were associated and analyzed statistically. Results The sample was comprised of 32 subjects, both men and women, with a higher number of women. Mean age was 71.41 ± 12.14 years. Self-assessment of hearing ranged from 2 to 9 points. Overall, 71.9% of the subjects purchased hearing aids. There was no association between scores in the self-assessment and the purchase of hearing aids (p = 0.263. Among those who scored between 2 and 5 points, 64.7% purchased the device; between 6 and 7 points, 76.09% purchased the device; and between 8 and 9 points, 50% purchased the device, respectively. Conclusion There is evidence that low self-assessment scores lead to the purchase of hearing aids, although no significant association was observed in the sample.

  7. Is AGC beneficial in hearing aids?

    Science.gov (United States)

    King, A B; Martin, M C

    1984-02-01

    Three different functions of Automatic Gain Control (AGC) circuits in hearing aids are distinguished and the evidence for their benefits is considered. The value of AGC's function as a relatively distortion-free means of limiting output has been well established. With regard to compression, the benefit of short-term or 'syllabic' compression has not been demonstrated convincingly. Most evaluations of this type of AGC have looked for increase in speech intelligibility, but theoretical predictions of its effect do not appear to take account of the acoustic cues to consonant contrasts actually used by hearing impaired people, and empirical studies have often used listening conditions which do not give a realistic test of benefit. Relatively little attention has been paid to long-term compression, or to the effect of AGC on comfort rather than intelligibility. Listening tests carried out at the RNID and reported here have shown that AGC can benefit hearing aid users by allowing them to listen to a wider range of sound levels without either strain or discomfort, and, if time constants are well chosen, without adverse effects on speech intelligibility in quiet or in noise.

  8. What factors influence help-seeking for hearing impairment and hearing aid adoption in older adults?

    Science.gov (United States)

    Meyer, Carly; Hickson, Louise

    2012-02-01

    The purpose of this review paper was to identify factors that influence older adults' decisions to seek help for hearing impairment and to adopt hearing aids. A literature search of abstracts within peer-reviewed journal articles published in English between 1990 and 2010 was conducted in online bibliographic databases using the keywords: hearing; impair* or loss; seek* or candidate* or applicant* or acquir*; and hearing aid* or help or advice. Twenty-two articles that were directly relevant to this topic were included in this review. The evidence suggests that individuals are more likely to seek help for hearing impairment and/or adopt hearing aids if they: (1) have a moderate to severe hearing impairment and self-reported hearing-related activity limitations or participation restrictions; (2) are older; (3) perceive their hearing as poor; (4) consider there to be more benefits than barriers to amplification; and (5) perceive their significant other/s as supportive of hearing rehabilitation. A barrier to help-seeking for hearing impairment and hearing aid adoption appears to be general practitioners' management of age-related hearing impairment.

  9. Vibrant SoundBridge application to middle ear windows versus conventional hearing aids: a comparative study based on international outcome inventory for hearing aids.

    Science.gov (United States)

    Atas, Ahmet; Tutar, Hakan; Gunduz, Bulent; Bayazıt, Yıldırım A

    2014-01-01

    In this study, we aimed to compare the outcomes of satisfaction of the patients who used hearing aids preceding the vibrant sound bridge (VSB) application on middle ear windows (14 oval window and 5 round window). Nineteen adult patients with conductive or mixed hearing loss were included in the study. All patients used behind the ear hearing aids on the site which was selected for VSB application. The patients used hearing aids for at least 3 months before the VSB operation. The floating mass transducer (FMT) was placed on one of the middle ear windows (oval or round) in VSB operation. The patients were evaluated with International Outcome Inventory for Hearing Aids (IOI-HA) preoperatively after at least 3 months trial of conventional hearing aid and postoperatively after 3 months use of VSB. No perioperative problem was encountered. The total score of IOI-HA was significantly higher with VSB compared with conventional hearing aids (p 0.05). The IOI-HA scores were significantly higher with the middle ear implant than the conventional hearing aid regarding benefit and residual participation restrictions (p < 0.05). Although the scores for quality of life assessment was similar between VSB and hearing aid use, there was a superiority of VSB in terms of benefit and residual participation restrictions as well as overall IOI-HA scores as the FMT was placed on one of the middle ear windows.

  10. Comparison of Carina active middle-ear implant with conventional hearing aids for mixed hearing loss.

    Science.gov (United States)

    Savaş, V A; Gündüz, B; Karamert, R; Cevizci, R; Düzlü, M; Tutar, H; Bayazit, Y A

    2016-04-01

    To compare the auditory outcomes of Carina middle-ear implants with those of conventional hearing aids in patients with moderate-to-severe mixed hearing loss. The study comprised nine patients (six males, three females) who underwent middle-ear implantation with Carina fully implantable active middle-ear implants to treat bilateral moderate-to-severe mixed hearing loss. The patients initially used conventional hearing aids and subsequently received the Carina implants. The hearing thresholds with implants and hearing aids were compared. There were no significant differences between: the pre-operative and post-operative air and bone conduction thresholds (p > 0.05), the thresholds with hearing aids and Carina implants (p > 0.05), or the pre-operative (mean, 72.8 ± 19 per cent) and post-operative (mean, 69.9 ± 24 per cent) speech discrimination scores (p > 0.05). One of the patients suffered total sensorineural hearing loss three months following implantation despite an initial 38 dB functional gain. All except one patient showed clinical improvements after implantation according to quality of life questionnaire (Glasgow Benefit Inventory) scores. Acceptance of Carina implants is better than with conventional hearing aids in patients with mixed hearing loss, although both yield similar hearing amplification. Cosmetic reasons appear to be critical for patient acceptance.

  11. Hearing Aids: How to Choose the Right One

    Science.gov (United States)

    Hearing aids: How to choose the right one Many types of hearing aids exist. So which is best for you? Find out what to consider when choosing a hearing ... used to the device and decide if it's right for you. Have the dispenser put in writing ...

  12. HEARING AID USE IN PATIENTS WITH PRESBYACUSIS: A QUESTIONNAIRE SURVEY

    Directory of Open Access Journals (Sweden)

    A. Karimaneh A. Eftekharian

    2004-11-01

    Full Text Available The acceptability of hearing aids in people with presbyacusis has been improved but assessment of whether there is a need for more counseling to increase the number of regular hearing-aid users seems to be important. The aim of this study was to determine if the hearing aid was worn regularly and over a long period of time in people with presbyacusis. A questionnaire survey of patients with presbyacusis who had been fitted with a monaural behind the ear hearing aid for the first time was undertaken. The patients were divided into four groups ranging from 6 months to 3 years after fitting. Overall regular long-term use of the hearing aid was found in the majority of patients with presbyacusis. The main dropout point was within the first year after fitting the hearing aid. The study furthermore revealed a relatively high demand for further help and advice with the hearing aid in all groups.

  13. Self-Fitting Hearing Aids

    Directory of Open Access Journals (Sweden)

    Gitte Keidser

    2016-04-01

    Full Text Available A self-contained, self-fitting hearing aid (SFHA is a device that enables the user to perform both threshold measurements leading to a prescribed hearing aid setting and fine-tuning, without the need for audiological support or access to other equipment. The SFHA has been proposed as a potential solution to address unmet hearing health care in developing countries and remote locations in the developed world and is considered a means to lower cost and increase uptake of hearing aids in developed countries. This article reviews the status of the SFHA and the evidence for its feasibility and challenges and predicts where it is heading. Devices that can be considered partly or fully self-fitting without audiological support were identified in the direct-to-consumer market. None of these devices are considered self-contained as they require access to other hardware such as a proprietary interface, computer, smartphone, or tablet for manipulation. While there is evidence that self-administered fitting processes can provide valid and reliable results, their success relies on user-friendly device designs and interfaces and easy-to-interpret instructions. Until these issues have been sufficiently addressed, optional assistance with the self-fitting process and on-going use of SFHAs is recommended. Affordability and a sustainable delivery system remain additional challenges for the SFHA in developing countries. Future predictions include a growth in self-fitting products, with most future SFHAs consisting of earpieces that connect wirelessly with a smartphone and providers offering assistance through a telehealth infrastructure, and the integration of SFHAs into the traditional hearing health-care model.

  14. Achieving effective hearing aid fitting within one month after identification of childhood permanent hearing impairment.

    Science.gov (United States)

    Bastanza, G; Gallus, R; De Carlini, M; Picciotti, P M; Muzzi, E; Ciciriello, E; Orzan, E; Conti, G

    2016-02-01

    Diagnosis of child permanent hearing impairment (PHI) can be made with extreme timeliness compared to the past thanks to improvements in PHI identification through newborn hearing screening programmes. It now becomes essential to provide an effective amplification as quickly as possible in order to restore auditory function and favour speech and language development. The early fitting of hearing aids and possible later cochlear implantation indeed prompts the development of central auditory pathways, connections with secondary sensory brain areas, as well as with motor and articulatory cortex. The aim of this paper is to report the results of a strategic analysis that involves identification of strengths, weaknesses, opportunities and threats regarding the process of achieving early amplification in all cases of significant childhood PHI. The analysis is focused on the Italian situation and is part of the Italian Ministry of Health project CCM 2013 "Preventing Communication Disorders: a Regional Program for Early Identification, Intervention and Care of Hearing Impaired Children". © Copyright by Società Italiana di Otorinolaringologia e Chirurgia Cervico-Facciale.

  15. A Hearing Aid Primer 1

    Science.gov (United States)

    Yetter, Carol J.

    2009-01-01

    This hearing aid primer is designed to define the differences among the three levels of hearing instrument technology: conventional analog circuit technology (most basic), digitally programmable/analog circuit technology (moderately advanced), and fully digital technology (most advanced). Both moderate and advanced technologies mean that hearing…

  16. Improving Hearing Aid Self-Efficacy and Utility Through Revising a Hearing Aid User Guide: A Pilot Study.

    Science.gov (United States)

    McMullan, Alexandra; Kelly-Campbell, Rebecca J; Wise, Kim

    2018-03-08

    This pilot study aimed to investigate whether revising a hearing aid user guide (HAUG) is associated with improved hearing aid self-efficacy and utility performance. In Part 1, an HAUG was evaluated using the Suitability Assessment of Material (SAM) and readability formulas (Flesch Reading Ease [Flesch, 1943], Flesch-Kincaid Readability Formula [Kincaid, Fishburne, Rogers, & Chissom, 1957], and Simple Measure of Gobbledygook [McLaughlin, 1969]). The HAUG was revised using results from the SAM and best practice guidelines. The revision included generating a video. In Part 2, 30 adults with hearing impairment were randomly assigned to use either the original guide (N = 15) or the revised guide and video (N = 15) to perform a utility task. Participants' self-efficacy was measured using the Basic and Advanced Handling subscales of the Measure of Audiologic Rehabilitation Self-Efficacy for Hearing Aids questionnaire. SAM and readability were compared between the original and revised guides (Doak, Doak, & Root, 1996). SAM and readability were improved following the revision. Participants in the revised guide group performed significantly better on the utility task and on the Measure of Audiologic Rehabilitation Self-Efficacy for Hearing Aids subscales than participants in the original guide group. These results are encouraging as they indicate that there is scope to influence self-efficacy and utility performance through the use of appropriate HAUGs.

  17. Effectiveness of an online SUpport PRogramme (SUPR) for older hearing aid users: study protocol for a cluster randomised controlled trial.

    Science.gov (United States)

    Meijerink, Janine Fj; Pronk, Marieke; Paulissen, Bernadette; Witte, Birgit I; Wouden, Bregje van der; Jansen, Vera; Kramer, Sophia E

    2017-06-20

    An educational SUpport PRogramme called SUPR has been developed for hearing aid users (HAUs) and their communication partners (CPs) offering care beyond hearing aid fitting. SUPR teaches its users communication strategies, hearing aid handling skills and personal adjustment to hearing impairment. Using a cluster randomised controlled trial design, 70 Dutch hearing aid dispenser practices were randomised into hearing aid fitting (care as usual, 34 practices) and hearing aid fitting including SUPR (36 practices). The aim was to recruit a total of 569 older (aged 50+ years) first-time (n=258) and experienced (n=311) HAUs and their CPs. SUPR consists of a Practical Support Booklet and online material offered via email over a period of 6-7 months. The booklet provides practical information on hearing aids, advice on communication strategies and home exercises. The online material consists of educational videos on hearing aid functionality and usage, communication strategies and peer testimonials. Finally, noncommittal email contact with the dispenser is offered. Every HAU is asked to assign a CP who is advised to be involved intensively. Effect measurements for HAUs and their CPs will occur at baseline and at 6, 12 and 18 months follow-up via online questionnaires. The primary outcomes for HAUs will be the use of communication strategies as measured by the subscales of the Communication Profile for the Hearing Impaired. A process evaluation will be performed. The study was approved by the Dutch Institutional Review Board of the VU Medical University Center Amsterdam. This intervention could contribute to lowering the hearing impairment burden in our ageing society. The results will be disseminated through peer-reviewed publications and scientific conferences. ISRCTN77340339; Pre-results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly

  18. The Modern Hearing Aid – an Extreme System Integration Challenge

    DEFF Research Database (Denmark)

    Jørgensen, Ivan Harald Holger

    (Application Specific Integrated Circuit) to produce a competitive advantage in terms of size and features. This presentation will give a brief insight into the hearing aid market and industry and a brief view of the historic development of hearing aids. The system integration challenge will be illustrated......People with reduced hearing generally want to hide this disability and thus the size of hearing aids is constantly decreasing in the effort to make them virtually invisible. However, as for all other modern electrical devices more and more features are constantly added to hearing aids driven...

  19. Prevalence of Contralateral Hearing Aid Use in Adults with Cochlear Implants

    Directory of Open Access Journals (Sweden)

    Yamaguchi, Cintia Tizue

    2013-09-01

    Full Text Available Introduction: The exclusive use of a cochlear implant (CI in one ear allows patients to effectively hear speech in a quiet environment. However, in environments with competing noise, the processing of multiple sounds becomes complex. In an attempt to promote binaural hearing in a noninvasive manner, the use of a hearing aid in the nonimplanted ear is suggested for patients with a unilateral CI. Aims: To identify the prevalence of hearing aid use in the contralateral ear in adults who already have a CI; to determine the reasons why some patients do not use contralateral hearing aids (CHAs; and to analyze the effects of residual hearing in CHA users. Materials and Methods: This is a clinical study in 82 adult patients with CI implants who responded to a questionnaire designed to determine current use of CHA. Results: In our patient sample, 70 CHA nonusers were identified. The prevalence of CHA users was determined to be 12% with a 95% confidence interval of 11 to 13%. About 58.2% of the CHA nonusers reported a lack of noticeable benefit even after wearing hearing aids, and 23.6% reported not having received the option to use a CHA. CHA users had a pure tone average of 107-dB hearing level, whereas CHA nonusers had a pure tone average of 117-dB hearing level. Conclusion: The prevalence of the use of a CHA is low in our study. We attribute the low use of a CHA to either a lack of residual hearing or to a lack of benefit from the amplification.

  20. Development of a music perception test for adult hearing-aid users

    Directory of Open Access Journals (Sweden)

    Marinda Uys

    2011-11-01

    Full Text Available The purpose of this research was two-fold. Firstly to develop a music perception test for hearing aid users and secondly to evaluate the influence of non-linear frequency compression (NFC on music perception with the use of the self-compiled test. This article focuses on the description of the development and validation of a music perception test. To date, the main direction in frequency lowering hearing aid studies has been in relation to speech perception abilities. With improvements in hearing aid technology, interest in musical perception as a dimension that could improve hearing aid users’ quality of life grew. The Music Perception Test (MPT was designed to evaluate different aspects of rhythm, timbre, pitch and melody. The development of the MPT could be described as design based. Phase 1 of the study included test development and recording while Phase 2 entailed presentation of stimuli to normal hearing listeners (n=15 and hearing aid users (n=4. Based on the findings of Phase 2, item analysis was performed to eliminate or change stimuli that resulted in high error rates. During Phase 3 the adapted version of the test was performed on a smaller group of normal hearing listeners (n=4 and twenty hearing aid users. Results proved that normal hearing adults as well as adults using hearing aids were able to complete all the sub-tests of the MPT although hearing aid users scored less on the various sub-tests than normal hearing listeners. For the rhythm section of the MPT normal hearing listeners scored on average 93.8% versus 75.5% of hearing aid users and 83% for the timbre section compared to 62.3% by hearing aid users. Normal hearing listeners obtained an average score of 86.3% for the pitch section and 88.2% for the melody section compared to the 70.8% and 61.9% respectively obtained by hearing aid users. This implicates that the MPT can be used successfully for assessment of music perception in hearing aid users within the South African

  1. Teachers' Perceptions of Adolescent Girls Who Wear Hearing Aids.

    Science.gov (United States)

    Cox, Linda R.; And Others

    1989-01-01

    Females, aged 10-14, were photographed wearing a body aid, a postauricular aid, or no hearing aid. Ratings by 60 college education majors indicated that subjects pictured wearing a hearing aid were rated lower on achievement but higher on factors of appearance, personality, and assertiveness than subjects without the aid. (Author/JDD)

  2. Rurality and determinants of hearing healthcare in adult hearing aid recipients.

    Science.gov (United States)

    Chan, Stephen; Hixon, Brian; Adkins, Margaret; Shinn, Jennifer B; Bush, Matthew L

    2017-10-01

    The objective of this study was to compare the timing of hearing aid (HA) acquisition between adults in rural and urban communities. We hypothesized that time of acquisition of HA after onset of hearing loss is greater in rural adults compared with urban adults. Secondary objectives included assessment of socioeconomic/educational status and impact of hearing loss and hearing rehabilitation of urban and rural HA recipients. Cross-sectional questionnaire survey. We assessed demographics, timing of HA fitting from onset of hearing loss, and impact of hearing impairment in 336 adult HA recipients (273 urban, 63 rural) from a tertiary referral center. Amplification benefit was assessed using the International Outcome Inventory for Hearing Aids (IOI). The time to HA acquisition was greater for rural participants compared to urban participants (19.1 vs. 25.7 years, P = 0.024) for those with untreated hearing loss for at least 8 years. Age at hearing loss onset was correlated with time to HA acquisition (P = -0.54, P hearing specialists (68 vs. 32 minutes, P Hearing impairment caused job performance difficulty in 60% of all participants. Rural adults are at risk for delayed HA acquisition, which may be related to distance to hearing specialists. Further research is indicated to investigate barriers to care and expand access for vulnerable populations. 4. Laryngoscope, 127:2362-2367, 2017. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.

  3. Evaluation of a Modified User Guide for Hearing Aid Management.

    Science.gov (United States)

    Caposecco, Andrea; Hickson, Louise; Meyer, Carly; Khan, Asaduzzaman

    2016-01-01

    This study investigated if a hearing aid user guide modified using best practice principles for health literacy resulted in superior ability to perform hearing aid management tasks, compared with the user guide in the original form. This research utilized a two-arm study design to compare the original manufacturer's user guide with a modified user guide for the same hearing aid--an Oticon Acto behind-the-ear aid with an open dome. The modified user guide had a lower reading grade level (4.2 versus 10.5), used a larger font size, included more graphics, and had less technical information. Eighty-nine adults ages 55 years and over were included in the study; none had experience with hearing aid use or management. Participants were randomly assigned either the modified guide (n = 47) or the original guide (n = 42). All participants were administered the Hearing Aid Management test, designed for this study, which assessed their ability to perform seven management tasks (e.g., change battery) with their assigned user guide. The regression analysis indicated that the type of user guide was significantly associated with performance on the Hearing Aid Management test, adjusting for 11 potential covariates. In addition, participants assigned the modified guide required significantly fewer prompts to perform tasks and were significantly more likely to perform four of the seven tasks without the need for prompts. The median time taken by those assigned the modified guide was also significantly shorter for three of the tasks. Other variables associated with performance on the Hearing Aid Management test were health literacy level, finger dexterity, and age. Findings indicate that the need to design hearing aid user guides in line with best practice principles of health literacy as a means of facilitating improved hearing aid management in older adults.

  4. The psychosocial impact of hearing aids in children with otitis media with effusion.

    Science.gov (United States)

    Qureishi, A; Garas, G; Mallick, A; Parker, D

    2014-11-01

    In children, otitis media with effusion is treated using grommets or hearing aids. Parents considering treatment options express concerns regarding the psychosocial impact of hearing aids in terms of self-esteem and bullying. This study assessed the psychosocial impact of hearing aid use. A cross-sectional study was undertaken comparing hearing aid users to non hearing aid users with regard to their attitudes towards hearing aids. All subjects, who had been diagnosed with otitis media with effusion, were aged less than 16 years, were without disability and attended mainstream schools. A questionnaire was designed and utilised. The study comprised 47 children with hearing aids and 50 with grommets. Significant between-group differences (p negative perceptions of non hearing aid users were not reported by hearing aid users. Children with hearing aids do not suffer from bullying or low self-esteem to the extent perceived by parents. This information is useful for informed decisions regarding treatment of otitis media with effusion.

  5. Self-reported disability and handicap after hearing-aid fitting and benefit of hearing aids: comparison of fitting procedures, degree of hearing loss, experience with hearing aids and uni- and bilateral fittings

    NARCIS (Netherlands)

    Metselaar, Mick; Maat, Bert; Krijnen, Pieta; Verschuure, Hans; Dreschler, Wouter A.; Feenstra, Louw

    2009-01-01

    Self-reported outcome on hearing disability and handicap as well as overall health-related quality of life were measured after hearing-aid fitting in a large-scale clinical population. Fitting was performed according to two different procedures in a double-blind study design. We used a comparative

  6. Self-reported disability and handicap after hearing-aid fitting and benefit of hearing aids : comparison of fitting procedures, degree of hearing loss, experience with hearing aids and uni- and bilateral fittings

    NARCIS (Netherlands)

    Metselaar, Mick; Maat, Bert; Krijnen, Pieta; Verschuure, Hans; Dreschler, Wouter A; Feenstra, Louw

    Self-reported outcome on hearing disability and handicap as well as overall health-related quality of life were measured after hearing-aid fitting in a large-scale clinical population. Fitting was performed according to two different procedures in a double-blind study design. We used a comparative

  7. Challenges and Recent Developments in Hearing Aids: Part II. Feedback and Occlusion Effect Reduction Strategies, Laser Shell Manufacturing Processes, and Other Signal Processing Technologies

    Science.gov (United States)

    Chung, King

    2004-01-01

    This is the second part of a review on the challenges and recent developments in hearing aids. Feedback and the occlusion effect pose great challenges in hearing aid design and usage. Yet, conventional solutions to feedback and the occlusion effect often create a dilemma: the solution to one often leads to the other. This review discusses the advanced signal processing strategies to reduce feedback and some new approaches to reduce the occlusion effect. Specifically, the causes of three types of feedback (acoustic, mechanical, and electromagnetic) are discussed. The strategies currently used to reduce acoustic feedback (i.e., adaptive feedback reduction algorithms using adaptive gain reduction, notch filtering, and phase cancellation strategies) and the design of new receivers that are built to reduce mechanical and electromagnetic feedback are explained. In addition, various new strategies (i.e., redesigned sound delivery devices and receiver-in-the-ear-canal hearing aid configuration) to reduce the occlusion effect are reviewed. Many manufacturers have recently adopted laser shell-manufacturing technologies to overcome problems associated with manufacturing custom hearing aid shells. The mechanisms of selected laser sintering and stereo lithographic apparatus and the properties of custom shells produced by these two processes are reviewed. Further, various new developments in hearing aid transducers, telecoils, channel-free amplification, open-platform programming options, rechargeable hearing aids, ear-level frequency modulated (FM) receivers, wireless Bluetooth FM systems, and wireless programming options are briefly explained and discussed. Finally, the applications of advanced hearing aid technologies to enhance other devices such as cochlear implants, hearing protectors, and cellular phones are discussed. PMID:15735871

  8. Buying a Hearing Aid

    Science.gov (United States)

    ... in price according to style, features, and local market prices. Price can range from hundreds of dollars to more than $2,500 for a programmable, digital hearing aid. Purchase price should not be the ...

  9. The importance of creating a social business to produce low-cost hearing aids.

    Science.gov (United States)

    Caccamo, Samantha; Voloshchenko, Anastasia; Dankyi, Nana Yaa

    2014-09-01

    The World Health Organization (WHO) estimates that about 280 million people worldwide have a bilateral hearing loss, mostly living in poor countries. Hearing loss causes heavy social burdens on individuals, families, communities and countries. However, due to the lack of accessibility and affordability, the vast majority of people in the world who need hearing aids do not have access to them. Low-income countries are thus pulled into a disability/poverty spiral. From this standpoint, the production of available, accessible and affordable hearing aids for the poorest populations of our planet should be one of the main issues in global hearing healthcare. Designing and producing a brand new low-cost hearing aid is the most effective option. Involving a large producer of hearing aids in the creation of a social business to solve the problem of access to affordable hearing aids is an essential step to reduce hearing disability on a large scale globally. Today's technology allows for the creation of a "minimal design" product that does not exceed $100-$150, that can be further lowered when purchased in large quantities and dispensed with alternative models. It is conceivable that by making a sustainable social business, the low cost product could be sold with a cross-subsidy model in order to recover the overhead costs. Social business is an economic model that has the potential to produce and distribute affordable hearing aids in low- and middle-income countries. Rehabilitation of hearing impaired children will be carried out in partnership with Sahic (Society of Assistance to Hearing Impaired Children) in Dhaka, Bangladesh and the ENT Department of Ospedale Burlo di Trieste, Dr. Eva Orzan.

  10. Exploring Audiologists' Language and Hearing Aid Uptake in Initial Rehabilitation Appointments.

    Science.gov (United States)

    Sciacca, Anna; Meyer, Carly; Ekberg, Katie; Barr, Caitlin; Hickson, Louise

    2017-06-13

    The study aimed (a) to profile audiologists' language during the diagnosis and management planning phase of hearing assessment appointments and (b) to explore associations between audiologists' language and patients' decisions to obtain hearing aids. Sixty-two audiologist-patient dyads participated. Patient participants were aged 55 years or older. Hearing assessment appointments were audiovisually recorded and transcribed for analysis. Audiologists' language was profiled using two measures: general language complexity and use of jargon. A binomial, multivariate logistic regression analysis was conducted to investigate the associations between these language measures and hearing aid uptake. The logistic regression model revealed that the Flesch-Kincaid reading grade level of audiologists' language was significantly associated with hearing aid uptake. Patients were less likely to obtain hearing aids when audiologists' language was at a higher reading grade level. No associations were found between audiologists' use of jargon and hearing aid uptake. Audiologists' use of complex language may present a barrier for patients to understand hearing rehabilitation recommendations. Reduced understanding may limit patient participation in the decision-making process and result in patients being less willing to trial hearing aids. Clear, concise language is recommended to facilitate shared decision making.

  11. How hearing aids, background noise, and visual cues influence objective listening effort.

    Science.gov (United States)

    Picou, Erin M; Ricketts, Todd A; Hornsby, Benjamin W Y

    2013-09-01

    The purpose of this article was to evaluate factors that influence the listening effort experienced when processing speech for people with hearing loss. Specifically, the change in listening effort resulting from introducing hearing aids, visual cues, and background noise was evaluated. An additional exploratory aim was to investigate the possible relationships between the magnitude of listening effort change and individual listeners' working memory capacity, verbal processing speed, or lipreading skill. Twenty-seven participants with bilateral sensorineural hearing loss were fitted with linear behind-the-ear hearing aids and tested using a dual-task paradigm designed to evaluate listening effort. The primary task was monosyllable word recognition and the secondary task was a visual reaction time task. The test conditions varied by hearing aids (unaided, aided), visual cues (auditory-only, auditory-visual), and background noise (present, absent). For all participants, the signal to noise ratio was set individually so that speech recognition performance in noise was approximately 60% in both the auditory-only and auditory-visual conditions. In addition to measures of listening effort, working memory capacity, verbal processing speed, and lipreading ability were measured using the Automated Operational Span Task, a Lexical Decision Task, and the Revised Shortened Utley Lipreading Test, respectively. In general, the effects measured using the objective measure of listening effort were small (~10 msec). Results indicated that background noise increased listening effort, and hearing aids reduced listening effort, while visual cues did not influence listening effort. With regard to the individual variables, verbal processing speed was negatively correlated with hearing aid benefit for listening effort; faster processors were less likely to derive benefit. Working memory capacity, verbal processing speed, and lipreading ability were related to benefit from visual cues. No

  12. Bone-anchored hearing aids in conductive and mixed hearing losses: why do patients reject them?

    Science.gov (United States)

    Siau, Richard T K; Dhillon, Baljeet; Siau, Derrick; Green, Kevin M J

    2016-10-01

    This study aimed to report the bone-anchored hearing aid uptake rate and the reasons for their rejection by patients with conductive and mixed hearing losses. A retrospective review was performed of 113 consecutive patients with unilateral or bilateral conductive or mixed hearing loss referred to the Greater Manchester bone-anchored hearing aid (BAHA) programme between September 2008 and August 2011. 98 (86.7 %) patients were deemed audiologically suitable for BAHA implantation. Of these, 38 (38.8 %) had BAHA implanted; 60 (61.2 %) patients declined. Of those who declined, 27 (45 %) cited anxiety over surgery, 18 (30 %) cited cosmetic reasons, 16 (26.7 %) perceived limited benefit from the device and six (10 %) preferred conventional hearing aids. Our study highlights a 38.8 % BAHA uptake rate in audiologically suitable patients. The main reasons cited for rejection of BAHA were anxiety over surgery and cosmetic concerns. It is important that clinicians address these early during consultation with prospective BAHA recipients and avoid rushing to implant these patients with a bone-anchored hearing aid.

  13. Improved Design of Microphone-Array Hearing Aids

    National Research Council Canada - National Science Library

    Greenberg, Julie

    1994-01-01

    ...). Research on microphone array hearing aids is motivated by the lack of success of single-microphone systems, as well as the documented advantages of binaural hearing and multiple-element sensing systems...

  14. Factors affecting the use and perceived benefit of ITE and BTE hearing aids.

    Science.gov (United States)

    Baumfield, A; Dillon, H

    2001-08-01

    The aim of the present study was to investigate factors that might affect hearing aid use, satisfaction and perceived benefit. A further aim was to look at which variables affect the choice of hearing aid, in particular, an in-the-ear (ITE) versus a behind-the-ear (BTE) device. Twenty-nine elderly hearing-impaired people with a mild-to-moderate hearing loss were fitted with both an ITE and a BTE hearing aid with similar electroacoustic performance. Both hearing aids were linear with output compression limiting and were fitted in a randomized order. After wearing each device for a six-week period, subj ets were asked to select the hearing aid they preferred. Variables significantly related to hearing aid choice, use and perceived benefit included ease of management, accuracy with which the NAL-R insertion gain target was achieved, earmould comfort and the type of hearing aid the client preferred initially.

  15. [Progressive noise induced hearing loss caused by hearing AIDS, a dilemma for the worker and the expert alike].

    Science.gov (United States)

    Feldmann, H

    2001-12-01

    Investigating cases of noise induced hearing loss the expert is often confronted with the situation that the hearing loss is progressive although the noise exposure has been reduced to almost non-damaging levels. Other causes such as age, hereditary deafness, head injuries, blasts, internal diseases can be excluded. Hearing aids as sources of damaging noise? By consulting the protocol of the hearing-aid acoustician and by own examinations the expert should obtain the following data: loudness level that yields best discrimination score of speech; level of discomfort for tones and speech, discrimination score that is achieved under free field condition with a speech level of 65 dB, using the hearing aids. Furthermore he should explore the circumstances under which the hearing aids are used: how many hours per day, at what occasions etc.? It is likely that in using the hearing aids they are adjusted to emit an intensity level identical to the one yielding the optimal discrimination score. If this e. g. is 100 dB and the hearing aids are used for 2 hours per day this would be equivalent to an exposure to industrial noise of 94 dB (A) for 8 hours daily without ear protection. Among all individuals working under industrial noise exposure today only about 1 - 2 % having unusually vulnerable inner ears will suffer a noise induced hearing loss. On the other hand workers in industrial noise are accustomed to loud noise levels, usually have a raised threshold of discomfort and therefore are likely to adjust their hearing aids to such high intensities. The expert will have to decide whether in an individual case the industrial noise exposure or the use of the hearing aids is the dominant risk for further damage. The consequences in respect to the regulations of the workers' health insurance are discussed.

  16. Speech understanding and directional hearing for hearing-impaired subjects with in-the-ear and behind-the-ear hearing aids

    NARCIS (Netherlands)

    Leeuw, A. R.; Dreschler, W. A.

    1987-01-01

    With respect to acoustical properties, in-the-ear (ITE) aids should give better understanding and directional hearing than behind-the-ear (BTE) aids. Also hearing-impaired subjects often prefer ITEs. A study was performed to assess objectively the improvement in speech understanding and directional

  17. Babies' Portal Website Hearing Aid Section: Assessment by Audiologists

    Directory of Open Access Journals (Sweden)

    Bastos, Bárbara Guimarães

    2014-02-01

    Full Text Available Introduction The family has ultimate responsibility for decisions about the use and care during the daily routine and problem solving in the manipulation of hearing aids (HA in infants and children. Objective The purpose of the study was to assess technical and content quality of Babies' Portal website Hearing Aid section by audiologists. Methods Letters and e-mails were sent inviting professionals to surf the website and anonymously fill out an online form with 58 questions covering demographic data as well as the website's technical (Emory questionnaire with the subscales of accuracy, authorship, updates, public, navigation, links, and structure and content quality. Results A total of 109 professionals (tree men and 106 women with mean age of 31.6 years participated in the study. Emory percentage scores ranged from 90.1 to 96.7%. The Hearing Aid section contents were considered good or very good. Conclusion The website was deemed to have good technical and content quality, being suitable to supplement informational counseling to parents of hearing-impaired children fitted with hearing aids.

  18. Vowel production of Mandarin-speaking hearing aid users with different types of hearing loss.

    Directory of Open Access Journals (Sweden)

    Yu-Chen Hung

    Full Text Available In contrast with previous research focusing on cochlear implants, this study examined the speech performance of hearing aid users with conductive (n = 11, mixed (n = 10, and sensorineural hearing loss (n = 7 and compared it with the speech of hearing control. Speech intelligibility was evaluated by computing the vowel space area defined by the Mandarin Chinese corner vowels /a, u, i/. The acoustic differences between the vowels were assessed using the Euclidean distance. The results revealed that both the conductive and mixed hearing loss groups exhibited a reduced vowel working space, but no significant difference was found between the sensorineural hearing loss and normal hearing groups. An analysis using the Euclidean distance further showed that the compression of vowel space area in conductive hearing loss can be attributed to the substantial lowering of the second formant of /i/. The differences in vowel production between groups are discussed in terms of the occlusion effect and the signal transmission media of various hearing devices.

  19. The Effects of Service-Delivery Model and Purchase Price on Hearing-Aid Outcomes in Older Adults: A Randomized Double-Blind Placebo-Controlled Clinical Trial.

    Science.gov (United States)

    Humes, Larry E; Rogers, Sara E; Quigley, Tera M; Main, Anna K; Kinney, Dana L; Herring, Christine

    2017-03-01

    The objectives of this study were to determine efficacy of hearing aids in older adults using audiology best practices, to evaluate the efficacy of an alternative over-the-counter (OTC) intervention, and to examine the influence of purchase price on outcomes for both service-delivery models. The design of this study was a single-site, prospective, double-blind placebo-controlled randomized trial with three parallel branches: (a) audiology best practices (AB), (b) consumer decides OTC model (CD), and (c) placebo devices (P). Outcome measures were obtained after a typical 6-week trial period with follow-up 4-week AB-based trial for those initially assigned to CD and P groups. Older adults from the general community were recruited via newspaper and community flyers to participate at a university research clinic. Participants were adults, ages 55-79 years, with mild-to-moderate hearing loss. There were 188 eligible participants: 163 enrolled as a volunteer sample, and 154 completed the intervention. All participants received the same high-end digital mini-behind-the-ear hearing aids fitted bilaterally. AB and P groups received best-practice services from audiologists; differing mainly in use of appropriate (AB) or placebo (P) hearing aid settings. CD participants self-selected their own pre-programmed hearing aids via an OTC model. Primary outcome measure was a 66-item self-report, Profile of Hearing Aid Benefit (Cox & Gilmore, 1990). Secondary outcome measure was the Connected Speech Test (Cox, Alexander, & Gilmore, 1987) benefit. Additional measures of hearing-aid benefit, satisfaction, and usage were also obtained. Per-protocol analyses were performed. AB service-delivery model was found to be efficacious for most of the outcome measures, with moderate or large effect sizes (Cohen's d). CD service-delivery model was efficacious, with similar effect sizes. However, CD group had a significantly (p purchase hearing aids after the trial. Hearing aids are efficacious in

  20. Motivational engagement in first-time hearing aid users: A feasibility study.

    Science.gov (United States)

    Ferguson, Melanie; Maidment, David; Russell, Naomi; Gregory, Melanie; Nicholson, Richard

    2016-07-01

    To assess (1) the feasibility of incorporating the Ida Institute's Motivation Tools into a UK audiology service, (2) the potential benefits of motivational engagement in first-time hearing aid users, and (3) predictors of hearing aid and general health outcome measures. A feasibility study using a single-centre, prospective, quasi-randomized controlled design with two arms. The Ida Institute's Motivation Tools formed the basis for motivational engagement. First-time hearing aid users were recruited at the initial hearing assessment appointment. The intervention arm underwent motivational engagement (M+, n = 32), and a control arm (M-, n = 36) received standard care only. The M+ group showed greater self-efficacy, reduced anxiety, and greater engagement with the audiologist at assessment and fitting appointments. However, there were no significant between-group differences 10-weeks post-fitting. Hearing-related communication scores predicted anxiety, and social isolation scores predicted depression for the M+ group. Readiness to address hearing difficulties predicted hearing aid outcomes for the M- group. Hearing sensitivity was not a predictor of outcomes. There were some positive results from motivational engagement early in the patient journey. Future research should consider using qualitative methods to explore whether there are longer-term benefits of motivational engagement in hearing aid users.

  1. Advantages of directional hearing aid microphones related to room acoustics

    NARCIS (Netherlands)

    Leeuw, A. R.; Dreschler, W. A.

    1991-01-01

    In this study, two types of hearing aids were used. Both aids had the same frequency characteristics for frontal sound, but one employed an omnidirectional microphone and the other a directional microphone. The frequency characteristics of both hearing aids were measured for five azimuths on KEMAR

  2. Concerns regarding Direct-to-Consumer Hearing Aid Purchasing

    Science.gov (United States)

    Kimball, Suzanne H.

    2010-01-01

    An individual over age 18 can purchase a hearing aid online or through mail order if they sign a waiver declining a medical evaluation, while those under 18 are required to be seen by a physician to obtain medical consent. However, in many states there is nothing to prevent a parent or caregiver from purchasing hearing aids for their child from a…

  3. 47 CFR 20.19 - Hearing aid-compatible mobile handsets.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 2 2010-10-01 2010-10-01 false Hearing aid-compatible mobile handsets. 20.19... COMMERCIAL MOBILE RADIO SERVICES § 20.19 Hearing aid-compatible mobile handsets. (a) Scope of section..., consistent with its own marketing practices. However, if a manufacturer assigns different model device...

  4. Effect of hearing aids use on speech stimulus decoding through speech-evoked ABR

    Directory of Open Access Journals (Sweden)

    Renata Aparecida Leite

    Full Text Available Abstract Introduction The electrophysiological responses obtained with the complex auditory brainstem response (cABR provide objective measures of subcortical processing of speech and other complex stimuli. The cABR has also been used to verify the plasticity in the auditory pathway in the subcortical regions. Objective To compare the results of cABR obtained in children using hearing aids before and after 9 months of adaptation, as well as to compare the results of these children with those obtained in children with normal hearing. Methods Fourteen children with normal hearing (Control Group - CG and 18 children with mild to moderate bilateral sensorineural hearing loss (Study Group - SG, aged 7-12 years, were evaluated. The children were submitted to pure tone and vocal audiometry, acoustic immittance measurements and ABR with speech stimulus, being submitted to the evaluations at three different moments: initial evaluation (M0, 3 months after the initial evaluation (M3 and 9 months after the evaluation (M9; at M0, the children assessed in the study group did not use hearing aids yet. Results When comparing the CG and the SG, it was observed that the SG had a lower median for the V-A amplitude at M0 and M3, lower median for the latency of the component V at M9 and a higher median for the latency of component O at M3 and M9. A reduction in the latency of component A at M9 was observed in the SG. Conclusion Children with mild to moderate hearing loss showed speech stimulus processing deficits and the main impairment is related to the decoding of the transient portion of this stimulus spectrum. It was demonstrated that the use of hearing aids promoted neuronal plasticity of the Central Auditory Nervous System after an extended time of sensory stimulation.

  5. Maximum likelihood based multi-channel isotropic reverberation reduction for hearing aids

    DEFF Research Database (Denmark)

    Kuklasiński, Adam; Doclo, Simon; Jensen, Søren Holdt

    2014-01-01

    We propose a multi-channel Wiener filter for speech dereverberation in hearing aids. The proposed algorithm uses joint maximum likelihood estimation of the speech and late reverberation spectral variances, under the assumption that the late reverberant sound field is cylindrically isotropic....... The dereverberation performance of the algorithm is evaluated using computer simulations with realistic hearing aid microphone signals including head-related effects. The algorithm is shown to work well with signals reverberated both by synthetic and by measured room impulse responses, achieving improvements...

  6. Music and hearing aids--an introduction.

    Science.gov (United States)

    Chasin, Marshall

    2012-09-01

    Modern digital hearing aids have provided improved fidelity over those of earlier decades for speech. The same however cannot be said for music. Most modern hearing aids have a limitation of their "front end," which comprises the analog-to-digital (A/D) converter. For a number of reasons, the spectral nature of music as an input to a hearing aid is beyond the optimal operating conditions of the "front end" components. Amplified music tends to be of rather poor fidelity. Once the music signal is distorted, no amount of software manipulation that occurs later in the circuitry can improve things. The solution is not a software issue. Some characteristics of music that make it difficult to be transduced without significant distortion include an increased sound level relative to that of speech, and the crest factor- the difference in dB between the instantaneous peak of a signal and its RMS value. Clinical strategies and technical innovations have helped to improve the fidelity of amplified music and these include a reduction of the level of the input that is presented to the A/D converter.

  7. Hearing aid use and long-term health outcomes: hearing handicap, mental health, social engagement, cognitive function, physical health and mortality

    Science.gov (United States)

    Dawes, Piers; Cruickshanks, Karen J.; Fischer, Mary E.; Klein, Barbara E.K.; Klein, Ronald; Nondahl, David M.

    2016-01-01

    Objective To clarify the impact of hearing aids on mental health, social engagement, cognitive function, and physical health outcomes in older adults with hearing impairment. Design We assessed hearing handicap (Hearing Handicap Inventory for the Elderly; HHIE-S), cognition (Mini Mental State Exam, Trail Making, Auditory Verbal Learning, Digit-Symbol Substitution, Verbal Fluency, incidence of cognitive impairment), physical health (SF-12 physical component, basic and instrumental activities of daily living, mortality), social engagement (hours per week spent in solitary activities) and mental health (SF-12 mental component) at baseline, 5 years prior to baseline, and 5 and 11 years after baseline. Study sample Community-dwelling older adults with hearing impairment (N=666) from the Epidemiology of Hearing Loss Study cohort. Results There were no significant differences between hearing aid users and non-users in cognitive, social engagement or mental health outcomes at any time point. Aided HHIE-S was significantly better than unaided HHIE-S. At 11 years hearing aid users had significantly better SF-12 physical health scores (46.2 versus 41.2; p=0.03). There was no difference in incidence of cognitive impairment or mortality. Conclusion There was no evidence that hearing aids promote cognitive function, mental health, or social engagement. Hearing aids may reduce hearing handicap and promote better physical health. PMID:26140300

  8. Data mining of audiology patient records: factors influencing the choice of hearing aid type

    Science.gov (United States)

    2012-01-01

    Background This paper describes the analysis of a database of over 180,000 patient records, collected from over 23,000 patients, by the hearing aid clinic at James Cook University Hospital in Middlesbrough, UK. These records consist of audiograms (graphs of the faintest sounds audible to the patient at six different pitches), categorical data (such as age, gender, diagnosis and hearing aid type) and brief free text notes made by the technicians. This data is mined to determine which factors contribute to the decision to fit a BTE (worn behind the ear) hearing aid as opposed to an ITE (worn in the ear) hearing aid. Methods From PCA (principal component analysis) four main audiogram types are determined, and are related to the type of hearing aid chosen. The effects of age, gender, diagnosis, masker, mould and individual audiogram frequencies are combined into a single model by means of logistic regression. Some significant keywords are also discovered in the free text fields by using the chi-squared (χ2) test, which can also be used in the model. The final model can act a decision support tool to help decide whether an individual patient should be offered a BTE or an ITE hearing aid. Results The final model was tested using 5-fold cross validation, and was able to replicate the decisions of audiologists whether to fit an ITE or a BTE hearing aid with precision in the range 0.79 to 0.87. Conclusions A decision support system was produced to predict the type of hearing aid which should be prescribed, with an explanation facility explaining how that decision was arrived at. This system should prove useful in providing a "second opinion" for audiologists. PMID:22595091

  9. A self-fitting hearing aid: need and concept.

    Science.gov (United States)

    Convery, Elizabeth; Keidser, Gitte; Dillon, Harvey; Hartley, Lisa

    2011-12-01

    The need for reliable access to hearing health care services is growing globally, particularly in developing countries and in remotely located, underserved regions in many parts of the developed world. Individuals with hearing loss in these areas are at a significant disadvantage due to the scarcity of local hearing health care professionals and the high cost of hearing aids. Current approaches to making hearing rehabilitation services more readily available to underserved populations include teleaudiology and the provision of amplification devices outside of the traditional provider-client relationship. Both strategies require access to such resources as dedicated equipment and/or specially trained staff. Another possible strategy is a self-fitting hearing aid, a personal amplification device that is equipped with an onboard tone generator to enable user-controlled, automated, in situ audiometry; an onboard prescription to determine the initial hearing aid settings; and a trainable algorithm to enable user-controlled fine-tuning. The device is thus assembled, fitted, and managed by the user without the need for audiological or computer support. This article details the self-fitting concept and its potential application in both developing and developed countries. Potential advantages and disadvantages of such a device are discussed, and considerations for further investigations into the concept are presented. Overall, the concept is considered technologically viable with the main challenges anticipated to be development of clear, simple user instructions and a delivery model that ensures reliable supplies of instant-fit ear tips and batteries.

  10. Language-specific strategy for programming hearing aids - A double-blind randomized controlled crossover study.

    Science.gov (United States)

    Matsumoto, Nozomu; Suzuki, Nobuyoshi; Iwasaki, Satoshi; Ishikawa, Kazuha; Tsukiji, Hiroki; Higashino, Yoshie; Tabuki, Tomoko; Nakagawa, Takashi

    2018-08-01

    Voice-aligned compression (VAC) is a method used in Oticon's hearing aids to provide more comfortable hearing without sacrificing speech discrimination. The complex, non-linear compression curve for the VAC strategy is designed based on the frequency profile of certain spoken Western languages. We hypothesized that hearing aids could be further customized for Japanese-speaking users by modifying the compression curve using the frequency profile of spoken Japanese. A double-blind randomized controlled crossover study was performed to determine whether or not Oticon's modified amplification strategy (VAC-J) provides subjectively preferable hearing aids for Japanese-speaking hearing aid users compared to the same company's original amplification strategy (VAC). The participants were randomized to two groups. The VAC-first group received a pair of hearing aids programmed using the VAC strategy and wore them for three weeks, and then received a pair of hearing aids programmed using VAC-J strategy and wore them for three weeks. The VAC-J-first group underwent the same study, but they received hearing aids in the reverse sequence. A Speech, Spatial and Qualities (SSQ) questionnaire was administered before beginning to use the hearing aids, at the end of using the first pair of hearing aids, and at the end of using the second pair of hearing aids. Twenty-five participants that met the inclusion/exclusion criteria from January 1 to October 31, 2016, were randomized to two groups. Twenty-two participants completed the study. There were no statistically significant differences in the increment of SSQ scores between the participants when using the VAC- or the VAC-J-programmed hearing aids. However, participants preferred the VAC-J strategy to the VAC strategy at the end of the study, and this difference was statistically significant. Japanese-speaking hearing aid users preferred using hearing aids that were fitted with the VAC-J strategy. Our results show that the VAC strategy

  11. Development of a digital hearing aid to meet the Brazilian Government's Ordinance 587 (APAC).

    Science.gov (United States)

    Penteado, Silvio Pires; Bento, Ricardo Ferreira

    2010-01-01

    The treatment of sensorineural hearing loss is based on hearing aids, also known as individual sound amplification devices. The hearing aids purchased by the Brazilian Government, aiming at fulfilling public policies, are based on dedicated components, which bring about benefits, but also render them expensive and may impair repair services after manufacture's warranty expires. to design digital behind-the-ear hearing aids built from standardized components coming from the very supply chain of these manufacturers. experimental. to identify the supply chain of these manufacturers, request samples and set up hearing aids in the laboratory. The developed hearing aids did not show lesser electroacoustic characteristics when compared to those acquired by the Government, also being tested by the same reference international technical standard. It is possible to develop digital behind-the-ear hearing aids based on off-the-shelf components from hearing aid manufacturers' supply chain. Their advantages include low operational costs - for acquisition (with clear advantages for the Government) and service (advantage for the patient).

  12. Experimental investigation on corrosion properties of LDS MID for Hearing Aid applications

    DEFF Research Database (Denmark)

    Islam, Aminul; Hansen, Hans Nørgaard; Risager, Flemming

    2014-01-01

    The trend towards miniaturization is ever going in the hearing aid industry. The Moulded Interconnect Device (MID) technology can offer the unique possibility to reduce the size of the hearing aids by combining electrical and mechanical functions in the same components. On the other hand, one...... of the main concerns for MIDs in hearing aids is the corrosion of metal tracks. This paper investigates the corrosion of the MID parts based on different base materials, layer thickness and mechanical wear of the MIDs. The results presented in the paper will be useful for designing MIDs in hearing aids...

  13. Stethoscopes with hearing aid use: Case studies

    Directory of Open Access Journals (Sweden)

    Jacob, Regina Tangerino de Souza

    2013-01-01

    Full Text Available Introduction: Description for using stethoscopes adapted to hearing aids. Aim: To describe the adaptation of HAs to stethoscopes used by 2 students in the health field with bilateral hearing impairment. Case reports: Two subjects with hearing loss had their stethoscopes coupled to HAs because of the individual requirements of their professions (healthcare to perform auscultation. Conclusion: The improvement was measured in situ, and satisfaction was evaluated using a subjective questionnaire. The use of a stethoscope coupled to an HA allowed students with hearing loss to perform auscultation.

  14. Stethoscopes with hearing aid use: Case studies

    Science.gov (United States)

    Jacob, Regina Tangerino de Souza; Zambonato, Ticiana Cristina de Souza; Mondelli, Maria Fernanda Capoani Garcia

    2013-01-01

    Summary Introduction: Description for using stethoscopes adapted to hearing aids. Aim: To describe the adaptation of HAs to stethoscopes used by 2 students in the health field with bilateral hearing impairment. Case reports: Two subjects with hearing loss had their stethoscopes coupled to HAs because of the individual requirements of their professions (healthcare) to perform auscultation. Conclusion: The improvement was measured in situ, and satisfaction was evaluated using a subjective questionnaire. The use of a stethoscope coupled to an HA allowed students with hearing loss to perform auscultation. PMID:25992000

  15. Evaluation of user satisfaction of hearing aids (HA in the Amazon

    Directory of Open Access Journals (Sweden)

    Arakawa, Aline Megumi

    2010-03-01

    Full Text Available Introduction: The main function of human hearing is enabling oral communication. In this sense, hearing loss impairs severely communication skills and social relationships of individuals. Therefore, the project "USP in Rondônia" of FOB/USP conducts expeditions travelling to the municipality from Monte Negro/RO allowing the promotion of hearing health. Objective: To assess the level of satisfaction user with hearing aids (HA. Method: Was accomplished a prospective study of 18 individuals with hearing loss fitted with hearing aids in the Clinic of Oral and Fono Audiological Health from Monte Negro/RO. For the evaluation, we used the questionnaire for self-assessment IOI-HA (International Outcome Inventory for Hearing Aids. Results: Concerning the seven domains assessed, it was verified that the average referring to the use was 4.2, the benefit was 3.9, the limiting of residual activity was 3.7; the satisfaction was 4.4, the restriction of participation of residual activity was 3.8, the impact on others was 4.3 and 3.9 for the quality of life. Respecting the factors one and two, it was applied the statistical test t-Student founding no statistically significant difference. However, the analysis of the score relative to factors one and two showed good results as the individual's interaction with his hearing aid and with their environment, respectively. Conclusion: With this study, we can demonstrate the high grade of satisfaction from the use of hearing aids presented by the majority of the sample collected in all domains analyzed.

  16. Effects of hearing-aid dynamic range compression on spatial perception in a reverberant environment

    DEFF Research Database (Denmark)

    Hassager, Henrik Gert; Wiinberg, Alan; Dau, Torsten

    2017-01-01

    This study investigated the effects of fast-acting hearing-aid compression on normal-hearing and hearing-impaired listeners’ spatial perception in a reverberant environment. Three compression schemes—independent compression at each ear, linked compression between the two ears, and “spatially ideal......” compression operating solely on the dry source signal—were considered using virtualized speech and noise bursts. Listeners indicated the location and extent of their perceived sound images on the horizontal plane. Linear processing was considered as the reference condition. The results showed that both...... independent and linked compression resulted in more diffuse and broader sound images as well as internalization and image splits, whereby more image splits were reported for the noise bursts than for speech. Only the spatially ideal compression provided the listeners with a spatial percept similar...

  17. Age-related changes in auditory and cognitive abilities in elderly persons with hearing aids fitted at the initial stages of hearing loss

    Directory of Open Access Journals (Sweden)

    C. Obuchi

    2011-03-01

    Full Text Available In this study, we investigated the relation between the use of hearing aids at the initial stages of hearing loss and age-related changes in the auditory and cognitive abilities of elderly persons. 12 healthy elderly persons participated in an annual auditory and cognitive longitudinal examination for three years. According to their hearing level, they were divided into 3 subgroups - the normal hearing group, the hearing loss without hearing aids group, and the hearing loss with hearing aids group. All the subjects underwent 4 tests: pure-tone audiometry, syllable intelligibility test, dichotic listening test (DLT, and Wechsler Adult Intelligence Scale-Revised (WAIS-R Short Forms. Comparison between the 3 groups revealed that the hearing loss without hearing aids group showed the lowest scores for the performance tasks, in contrast to the hearing level and intelligibility results. The other groups showed no significant difference in the WAIS-R subtests. This result indicates that prescription of a hearing aid during the early stages of hearing loss is related to the retention of cognitive abilities in such elderly people. However, there were no statistical significant correlations between the auditory and cognitive tasks.

  18. Analysis, Design, and Evaluation of Acoustic Feedback Cancellation Systems for Hearing Aids

    DEFF Research Database (Denmark)

    Guo, Meng

    2013-01-01

    Acoustic feedback problems occur when the output loudspeaker signal of an audio system is partly returned to the input microphone via an acoustic coupling through the air. This problem often causes significant performance degradations in applications such as public address systems and hearing aids....... In the worst case, the audio system becomes unstable and howling occurs. In this work, first we analyze a general multiple microphone audio processing system, where a cancellation system using adaptive filters is used to cancel the effect of acoustic feedback. We introduce and derive an accurate approximation...... in acoustic feedback cancellation for hearing aids. It utilizes a probe noise signal which is generated with a specific characteristic so that it can facilitate an unbiased adaptive filter estimation with fast tracking of feedback path variations/changes despite its low signal level. We show in a hearing aid...

  19. Target-matched insertion gain derived from three different hearing aid selection procedures.

    Science.gov (United States)

    Punch, J L; Shovels, A H; Dickinson, W W; Calder, J H; Snead, C

    1995-11-01

    Three hearing aid selection procedures were compared to determine if any one was superior in producing prescribed real-ear insertion gain. For each of three subject groups, 12 in-the-ear style hearing aids with Class D circuitry and similar dispenser controls were ordered from one of three manufacturers. Subject groups were classified based on the type of information included on the hearing aid order form: (1) the subject's audiogram, (2) a three-part matrix specifying the desired maximum output, full-on gain, and frequency response slope of the hearing aid, or (3) the desired 2-cc coupler full-in grain of the hearing aid, based on real-ear coupler difference (RECD) measurements. Following electroacoustic adjustments aimed at approximating a commonly used target insertion gain formula, results revealed no significant differences among any of the three selection procedures with respect to obtaining acceptable insertion gain values.

  20. Language Outcomes in Children Who Are Deaf and Hard of Hearing: The Role of Language Ability Before Hearing Aid Intervention.

    Science.gov (United States)

    Daub, Olivia; Bagatto, Marlene P; Johnson, Andrew M; Cardy, Janis Oram

    2017-11-09

    Early auditory experiences are fundamental in infant language acquisition. Research consistently demonstrates the benefits of early intervention (i.e., hearing aids) to language outcomes in children who are deaf and hard of hearing. The nature of these benefits and their relation with prefitting development are, however, not well understood. This study examined Ontario Infant Hearing Program birth cohorts to explore predictors of performance on the Preschool Language Scale-Fourth Edition at the time of (N = 47) and after (N = 19) initial hearing aid intervention. Regression analyses revealed that, before the hearing aid fitting, severity of hearing loss negatively predicted 19% and 10% of the variance in auditory comprehension and expressive communication, respectively. After hearing aid fitting, children's standard scores on language measures remained stable, but they made significant improvement in their progress values, which represent individual skills acquired on the test, rather than standing relative to same-age peers. Magnitude of change in progress values was predicted by a negative interaction of prefitting language ability and severity of hearing loss for the Auditory Comprehension scale. These findings highlight the importance of considering a child's prefitting language ability in interpreting eventual language outcomes. Possible mechanisms of hearing aid benefit are discussed. https://doi.org/10.23641/asha.5538868.

  1. Advantages of binaural amplification to acceptable noise level of directional hearing aid users.

    Science.gov (United States)

    Kim, Ja-Hee; Lee, Jae Hee; Lee, Ho-Ki

    2014-06-01

    The goal of the present study was to examine whether Acceptable Noise Levels (ANLs) would be lower (greater acceptance of noise) in binaural listening than in monaural listening condition and also whether meaningfulness of background speech noise would affect ANLs for directional microphone hearing aid users. In addition, any relationships between the individual binaural benefits on ANLs and the individuals' demographic information were investigated. Fourteen hearing aid users (mean age, 64 years) participated for experimental testing. For the ANL calculation, listeners' most comfortable listening levels and background noise level were measured. Using Korean ANL material, ANLs of all participants were evaluated under monaural and binaural amplification with a counterbalanced order. The ANLs were also compared across five types of competing speech noises, consisting of 1- through 8-talker background speech maskers. Seven young normal-hearing listeners (mean age, 27 years) participated for the same measurements as a pilot testing. The results demonstrated that directional hearing aid users accepted more noise (lower ANLs) with binaural amplification than with monaural amplification, regardless of the type of competing speech. When the background speech noise became more meaningful, hearing-impaired listeners accepted less amount of noise (higher ANLs), revealing that ANL is dependent on the intelligibility of the competing speech. The individuals' binaural advantages in ANLs were significantly greater for the listeners with longer experience of hearing aids, yet not related to their age or hearing thresholds. Binaural directional microphone processing allowed hearing aid users to accept a greater amount of background noise, which may in turn improve listeners' hearing aid success. Informational masking substantially influenced background noise acceptance. Given a significant association between ANLs and duration of hearing aid usage, ANL measurement can be useful for

  2. User Centered Design as a Framework for Applying Conversation Analysis in Hearing Aid Consultations

    DEFF Research Database (Denmark)

    Egbert, Maria; Matthews, Ben

    2011-01-01

    collaboration, as well as successes and pitfalls. In particular we focus on the role of conversation analysists both from the perspective of the designers and the conversation analysts. To illustrate this, we have selected a project on hearing aid fitting. To understand the perspective of the users (the person...... with hearing loss and the hearing aid fitter is imperative because the compliance rate for hearing aid use is staggeringly low. One of the barriers of hearing aid use lies in problematic encounters between the person with hearing loss and audiologists. Buur, J and Matthews, B. (2008) ‘Participatory Innovation...

  3. Developing an appropriate digital hearing aid for low-resource countries: a case study.

    Science.gov (United States)

    Israsena, P; Isaradisaikul, S; Noymai, A; Boonyanukul, S; Hemakom, A; Chinnarat, C; Navacharoen, N; Lekagul, S

    2013-01-01

    This paper reviews the development process and discusses the key findings which resulted from our multidisciplinary research team's effort to develop an alternative digital hearing suitable for low-resource countries such as Thailand. A cost-effective, fully programmable digital hearing aid, with its specifications benchmarking against WHO's recommendations, was systematically designed, engineered, and tested. Clinically it had undergone a full clinical trial that employed the outcome measurement protocol adopted from the APHAB, the first time implemented in Thai language. Results indicated that using the hearing aid improves user's satisfaction in terms of ease of communication, background noises, and reverberation, with clear benefit after 3 and 6 months, confirming its efficacy. In terms of engineering, the hearing aid also proved to be robust, passing all the designated tests. As the technology has successfully been transferred to a local company for the production phase, we also discuss other challenges that may arise before the device can be introduced into the market.

  4. Investigating the Impact of Hearing Aid Use and Auditory Training on Cognition, Depressive Symptoms, and Social Interaction in Adults With Hearing Loss: Protocol for a Crossover Trial.

    Science.gov (United States)

    Nkyekyer, Joanna; Meyer, Denny; Blamey, Peter J; Pipingas, Andrew; Bhar, Sunil

    2018-03-23

    Sensorineural hearing loss is the most common sensory deficit among older adults. Some of the psychosocial consequences of this condition include difficulty in understanding speech, depression, and social isolation. Studies have shown that older adults with hearing loss show some age-related cognitive decline. Hearing aids have been proven as successful interventions to alleviate sensorineural hearing loss. In addition to hearing aid use, the positive effects of auditory training-formal listening activities designed to optimize speech perception-are now being documented among adults with hearing loss who use hearing aids, especially new hearing aid users. Auditory training has also been shown to produce prolonged cognitive performance improvements. However, there is still little evidence to support the benefits of simultaneous hearing aid use and individualized face-to-face auditory training on cognitive performance in adults with hearing loss. This study will investigate whether using hearing aids for the first time will improve the impact of individualized face-to-face auditory training on cognition, depression, and social interaction for adults with sensorineural hearing loss. The rationale for this study is based on the hypothesis that, in adults with sensorineural hearing loss, using hearing aids for the first time in combination with individualized face-to-face auditory training will be more effective for improving cognition, depressive symptoms, and social interaction rather than auditory training on its own. This is a crossover trial targeting 40 men and women between 50 and 90 years of age with either mild or moderate symmetric sensorineural hearing loss. Consented, willing participants will be recruited from either an independent living accommodation or via a community database to undergo a 6-month intensive face-to-face auditory training program (active control). Participants will be assigned in random order to receive hearing aid (intervention) for

  5. Investigating the Impact of Hearing Aid Use and Auditory Training on Cognition, Depressive Symptoms, and Social Interaction in Adults With Hearing Loss: Protocol for a Crossover Trial

    Science.gov (United States)

    Meyer, Denny; Blamey, Peter J; Pipingas, Andrew; Bhar, Sunil

    2018-01-01

    Background Sensorineural hearing loss is the most common sensory deficit among older adults. Some of the psychosocial consequences of this condition include difficulty in understanding speech, depression, and social isolation. Studies have shown that older adults with hearing loss show some age-related cognitive decline. Hearing aids have been proven as successful interventions to alleviate sensorineural hearing loss. In addition to hearing aid use, the positive effects of auditory training—formal listening activities designed to optimize speech perception—are now being documented among adults with hearing loss who use hearing aids, especially new hearing aid users. Auditory training has also been shown to produce prolonged cognitive performance improvements. However, there is still little evidence to support the benefits of simultaneous hearing aid use and individualized face-to-face auditory training on cognitive performance in adults with hearing loss. Objective This study will investigate whether using hearing aids for the first time will improve the impact of individualized face-to-face auditory training on cognition, depression, and social interaction for adults with sensorineural hearing loss. The rationale for this study is based on the hypothesis that, in adults with sensorineural hearing loss, using hearing aids for the first time in combination with individualized face-to-face auditory training will be more effective for improving cognition, depressive symptoms, and social interaction rather than auditory training on its own. Methods This is a crossover trial targeting 40 men and women between 50 and 90 years of age with either mild or moderate symmetric sensorineural hearing loss. Consented, willing participants will be recruited from either an independent living accommodation or via a community database to undergo a 6-month intensive face-to-face auditory training program (active control). Participants will be assigned in random order to receive

  6. Adaptive Feedback Cancellation With Band-Limited LPC Vocoder in Digital Hearing Aids

    DEFF Research Database (Denmark)

    Ma, Guilin; Gran, Fredrik; Jacobsen, Finn

    2011-01-01

    Feedback oscillation is one of the major issues with hearing aids. An effective way of feedback suppression is adaptive feedback cancellation, which uses an adaptive filter to estimate the feedback path. However, when the external input signal is correlated with the receiver input signal, the est......Feedback oscillation is one of the major issues with hearing aids. An effective way of feedback suppression is adaptive feedback cancellation, which uses an adaptive filter to estimate the feedback path. However, when the external input signal is correlated with the receiver input signal......, the estimate of the feedback path is biased. This so-called “bias problem” results in a large modeling error and a cancellation of the desired signal. This paper proposes a band-limited linear predictive coding based approach to reduce the bias. The idea is to replace the hearing-aid output with a synthesized...... and the misalignment between the real and the estimated feedback path. When combined with filtered-X adaptation in the feedback canceller, this approach reduces the misalignment even further....

  7. Hearing aid and cochlear implant use in children with hearing loss at three years of age: Predictors of use and predictors of changes in use

    Science.gov (United States)

    Marnane, Vivienne; Ching, Teresa YC

    2015-01-01

    Objective To examine usage patterns of hearing aids and cochlear implants in children up to three years of age, how usage changes longitudinally, and factors associated with device usage. Design Parent report and Parent’s Evaluation of Aural/oral performance of Children (PEACH) data were obtained at six and twelve months after hearing-aid fitting or cochlear implant switch-on, and again at three years of age. The effect of device use on auditory functional performance was investigated using the PEACH questionnaire. Study sample Four hundred and thirteen participants from the Longitudinal Outcomes of Children with Hearing Impairment (LOCHI) study were included for analysis. Result For users of hearing aids, higher usage at three years was associated with higher maternal education, and more severe hearing loss. For users of cochlear implants, higher usage was associated with higher maternal education and the absence of additional disabilities. Higher PEACH scores was associated with higher usage scores. After allowing for the effects of demographic characteristics, device use was not a significant predictor of functional performance. Conclusions Sixty-two percent of children achieved consistent use (>75% of waking hours) within the first year of receiving a hearing aid or a cochlear implant, and 71% by three years of age. PMID:25816866

  8. In situ Hearing Tests for the Purpose of a Self-Fit Hearing Aid

    NARCIS (Netherlands)

    Boymans, Monique; Dreschler, Wouter A.

    2017-01-01

    This study investigated the potential and limitations of a self-fit hearing aid. This can be used in the "developing" world or in countries with large distances between the hearing-impaired subjects and the professional. It contains an on-board tone generator for in situ user-controlled, automated

  9. Noise reduction in binaural hearing aids : Analyzing the benefit over monaural systems

    NARCIS (Netherlands)

    Srinivasan, S.

    2008-01-01

    Binaural beamforming using signals from both left and right hearing aids offers greater potential for noise reduction than using signals from a single aid. However, wireless transmission of data imposes power constraints. Since most modern hearing aids have multiple microphones and are capable of

  10. Web-based auditory self-training system for adult and elderly users of hearing aids.

    Science.gov (United States)

    Vitti, Simone Virginia; Blasca, Wanderléia Quinhoneiro; Sigulem, Daniel; Torres Pisa, Ivan

    2015-01-01

    THA portal, was finalized, rated by experts and hearing aid users and approved for use. The system comprised auditory skills training along five lines: discrimination; recognition; comprehension and temporal sequencing; auditory closure; and cognitive-linguistic and communication strategies. Users needed to undergo auditory training over a minimum period of 1 month: 5 times a week for 30 minutes a day. Comparisons were made between G1 and G2 and web system use by G3. The web system developed was approved for release to hearing aid users. It is expected that the self-training will help improve effective use of hearing aids, thereby decreasing their rejection.

  11. Wireless communication for hearing aid system

    DEFF Research Database (Denmark)

    Nour, Baqer

    This thesis focuses on the wireless coupling between hearing aids close to a human head. Hearing aids constitute devices withadvanced technology and the wireless communication enables the introduction of a range of completely new functionalities. Such devices are small and the available power...... the ear-to-ear wireless communication channel by understanding the mechanisms that control the propagations of the signals and the losses. The second objective isto investigate the properties of magneto-dielectric materials and their potential in antenna miniaturization. There are three approaches...... to study the ear-to-ear wireless communication link; a theoretical approach models the human head asa sphere that has the electrical properties of the head, a numerical approach implements a more realistic geometry of the head, and an experimental approach measures directly the coupling between...

  12. Ormiaochracea as a Model Organism in Sound Localization Experiments and in Inventing Hearing Aids.

    Directory of Open Access Journals (Sweden)

    - -

    1998-09-01

    Full Text Available Hearing aid prescription for patients suffering hearing loss has always been one of the main concerns of the audiologists. Thanks to technology that has provided Hearing aids with digital and computerized systems which has improved the quality of sound heard by hearing aids. Though we can learn from nature in inventing such instruments as in the current article that has been channeled to a kind of fruit fly. Ormiaochracea is a small yellow nocturnal fly, a parasitoid of crickets. It is notable because of its exceptionally acute directional hearing. In the current article we will discuss how it has become a model organism in sound localization experiments and in inventing hearing aids.

  13. Hearing aid processing of loud speech and noise signals: Consequences for loudness perception and listening comfort

    DEFF Research Database (Denmark)

    Schmidt, Erik

    2007-01-01

    sounds, has found that both normal-hearing and hearing-impaired listeners prefer loud sounds to be closer to the most comfortable loudness-level, than suggested by common non-linear fitting rules. During this project, two listening experiments were carried out. In the first experiment, hearing aid users......Hearing aid processing of loud speech and noise signals: Consequences for loudness perception and listening comfort. Sound processing in hearing aids is determined by the fitting rule. The fitting rule describes how the hearing aid should amplify speech and sounds in the surroundings......, such that they become audible again for the hearing impaired person. The general goal is to place all sounds within the hearing aid users’ audible range, such that speech intelligibility and listening comfort become as good as possible. Amplification strategies in hearing aids are in many cases based on empirical...

  14. Hearing Aids and Personal Sound Amplifiers: Know the Difference

    Science.gov (United States)

    ... Products For Consumers Home For Consumers Consumer Updates Hearing Aids and Personal Sound Amplifiers: Know the Difference ... that FDA launched today. Signs of Loss of Hearing Mann says that consumers who suspect they suffer ...

  15. Preliminary support for a brief psychological intervention to improve first-time hearing aid use among adults.

    Science.gov (United States)

    Armitage, Christopher J; Lees, Deborah; Lewis, Kathryn; Munro, Kevin J

    2017-11-01

    Suboptimal hearing aid use extorts significant social, health, and economic costs. The aims of this study were to (1) test the novel hypothesis that the threat associated with being diagnosed with hearing loss could be ameliorated with a self-affirmation manipulation and (2) gauge the feasibility of deploying the manipulation in routine clinical practice. Parallel groups randomized controlled trial with 10-week follow-up. Fifty people, newly prescribed with a hearing aid, completed either a questionnaire that included a brief self-affirming exercise or an identical questionnaire with no self-affirming exercise. The main outcome measure was derived from data logging automatically stored by the hearing aid. Perceived threat ('anxiety about ageing'), behavioural intention, and self-efficacy were measured as potential mediators. Objectively measured hours of daily hearing aid use were marginally higher in the intervention group compared with the control group (between-group difference = 1.94 hr, 95%CI = -1.24, 5.12, d = 0.43). At follow-up, participants in the intervention group were significantly less anxious about ageing and more accepting of older people than were participants in the control group (between-group difference = 0.75, 95%CI = 0.26, 1.22, d = 0.87). There was no statistically significant effect of the intervention on behavioural intention or self-efficacy. Although not statistically significant, the magnitude of the effect of the intervention on hearing aid use (d = 0.43) suggests that it would be worthwhile working towards a fully powered randomized controlled trial. The ability to reduce anxieties about ageing with this brief intervention could have far-reaching benefits for multiple patient and general population groups. Statement of contribution What is already known on this subject? Hearing impairment is more disabling than diabetes, yet hearing aid use is suboptimal. Anxieties about ageing may undermine hearing aid use. What does

  16. HIV/AIDS among Adolescents with Hearing Impairment in Nigeria ...

    African Journals Online (AJOL)

    AIDS to be elusive; such as prejudice against individuals with hearing impairment, lack of adequate data, exclusion from programmes that talk about sexuality, cultural beliefs, poor knowledge and attitude of adolescents with hearing impairment ...

  17. Effects of noise and working memory capacity on memory processing of speech for hearing-aid users.

    Science.gov (United States)

    Ng, Elaine Hoi Ning; Rudner, Mary; Lunner, Thomas; Pedersen, Michael Syskind; Rönnberg, Jerker

    2013-07-01

    It has been shown that noise reduction algorithms can reduce the negative effects of noise on memory processing in persons with normal hearing. The objective of the present study was to investigate whether a similar effect can be obtained for persons with hearing impairment and whether such an effect is dependent on individual differences in working memory capacity. A sentence-final word identification and recall (SWIR) test was conducted in two noise backgrounds with and without noise reduction as well as in quiet. Working memory capacity was measured using a reading span (RS) test. Twenty-six experienced hearing-aid users with moderate to moderately severe sensorineural hearing loss. Noise impaired recall performance. Competing speech disrupted memory performance more than speech-shaped noise. For late list items the disruptive effect of the competing speech background was virtually cancelled out by noise reduction for persons with high working memory capacity. Noise reduction can reduce the adverse effect of noise on memory for speech for persons with good working memory capacity. We argue that the mechanism behind this is faster word identification that enhances encoding into working memory.

  18. Remote hearing aid fitting: Tele-audiology in the context of Brazilian Public Policy

    Science.gov (United States)

    Penteado, Silvio Pires; Ramos, Sueli de Lima; Battistella, Linamara Rizzo; Marone, Silvio Antonio Monteiro; Bento, Ricardo Ferreira

    2012-01-01

    Summary Introduction: Currently, the Brazilian government has certificated nearly 140 specialized centers in hearing aid fittings through the Brazilian National Health System (SUS). Remote fitting through the Internet can allow a broader and more efficient coverage with a higher likelihood of success for patients covered by the SUS, as they can receive fittings from their own homes instead of going to the few and distant specialized centers. Aim: To describe a case of remote fitting between 2 cities, with revision of the literature. Method: Computer gears, a universal interface, and hearing aids were used. Case study: An audiologist located in a specialized center introduced a new hearing aid and its fitting procedure to a remote center (200 km away). The specialized center helped the remote center in fitting a hearing aid in 2 patients, and performed fitting in one of its own patients. The whole process was done through the Internet with audio and video in real time. Results: Three patients were fitted remotely. Three audiologists were remotely trained on how to fit the hearing aids. Conclusions: Remote fitting of hearing aids is possible through the Internet, as well as further supplying technical training to a remote center about the fitting procedures. Such a technological approach can help the government advance public policies on hearing rehabilitation, as patients can be motivated about maintaining their use of hearing aids with the option to ask for help in the comfort of their own homes. PMID:25991960

  19. Long-term tinnitus suppression with linear octave frequency transposition hearing AIDS.

    Directory of Open Access Journals (Sweden)

    Elisabeth Peltier

    Full Text Available Over the last three years of hearing aid dispensing, it was observed that among 74 subjects fitted with a linear octave frequency transposition (LOFT hearing aid, 60 reported partial or complete tinnitus suppression during day and night, an effect still lasting after several months or years of daily use. We report in more details on 38 subjects from whom we obtained quantified measures of tinnitus suppression through visual analog scaling and several additional psychoacoustic and audiometric measures. The long-term suppression seems independent of subject age, and of duration and subjective localization of tinnitus. A small but significant correlation was found with audiogram losses but not with high frequency loss slope. Long-term tinnitus suppression was observed for different etiologies, but with a low success rate for sudden deafness. It should be noted that a majority of subjects (23 had a history of noise exposure. Tinnitus suppression started after a few days of LOFT hearing aid use and reached a maximum after a few weeks of daily use. For nine subjects different amounts of frequency shifting were tried and found more or less successful for long-term tinnitus suppression, no correlation was found with tinnitus pitch. When the use of the LOFT hearing aid was stopped tinnitus reappeared within a day, and after re-using the LOFT aid it disappeared again within a day. For about one third of the 38 subjects a classical amplification or a non linear frequency compression aid was also tried, and no such tinnitus suppression was observed. Besides improvements in audiometric sensitivity to high frequencies and in speech discrimination scores, LOFT can be considered as a remarkable opportunity to suppress tinnitus over a long time scale. From a pathophysiological viewpoint these observations seem to fit with a possible re-attribution of activity to previously deprived cerebral areas corresponding to high frequency coding.

  20. The Performance-Perceptual Test (PPT) and its relationship to aided reported handicap and hearing aid satisfaction.

    Science.gov (United States)

    Saunders, Gabrielle H; Forsline, Anna

    2006-06-01

    Results of objective clinical tests (e.g., measures of speech understanding in noise) often conflict with subjective reports of hearing aid benefit and satisfaction. The Performance-Perceptual Test (PPT) is an outcome measure in which objective and subjective evaluations are made by using the same test materials, testing format, and unit of measurement (signal-to-noise ratio, S/N), permitting a direct comparison between measured and perceived ability to hear. Two variables are measured: a Performance Speech Reception Threshold in Noise (SRTN) for 50% correct performance and a Perceptual SRTN, which is the S/N at which listeners perceive that they can understand the speech material. A third variable is computed: the Performance-Perceptual Discrepancy (PPDIS); it is the difference between the Performance and Perceptual SRTNs and measures the extent to which listeners "misjudge" their hearing ability. Saunders et al. in 2004 examined the relation between PPT scores and unaided hearing handicap. In this publication, the relations between the PPT, residual aided handicap, and hearing aid satisfaction are described. Ninety-four individuals between the ages of 47 and 86 yr participated. All had symmetrical sensorineural hearing loss and had worn binaural hearing aids for at least 6 wk before participating. All subjects underwent routine audiological examination and completed the PPT, the Hearing Handicap Inventory for the Elderly/Adults (HHIE/A), and the Satisfaction for Amplification in Daily Life questionnaire. Sixty-five subjects attended one research visit for participation in this study, and 29 attended a second visit to complete the PPT a second time. Performance and Perceptual SRTN and PPDIS scores were normally distributed and showed excellent test-retest reliability. Aided SRTNs were significantly better than unaided SRTNs; aided and unaided PPDIS values did not differ. Stepwise multiple linear regression showed that the PPDIS, the Performance SRTN, and age were

  1. Provision of hearing aids to children in Bangladesh: costs and cost-effectiveness of a community-based and a centre-based approach.

    Science.gov (United States)

    Ekman, Björn; Borg, Johan

    2017-08-01

    The aim of this study is to provide evidence on the costs and health effects of two alternative hearing aid delivery models, a community-based and a centre-based approach. The study is set in Bangladesh and the study population is children between 12 and 18 years old. Data on resource use by participants and their caregivers were collected by a household survey. Follow-up data were collected after two months. Data on the costs to providers of the two approaches were collected by means of key informant interviews. The total cost per participant in the community-based model was BDT 6,333 (USD 79) compared with BDT 13,718 (USD 172) for the centre-based model. Both delivery models are found to be cost-effective with an estimated cost per DALY averted of BDT 17,611 (USD 220) for the community-based model and BDT 36,775 (USD 460) for the centre-based model. Using a community-based approach to deliver hearing aids to children in a resource constrained environment is a cost-effective alternative to the traditional centre-based approach. Further evidence is needed to draw conclusions for scale-up of approaches; rigorous analysis is possible using well-prepared data collection tools and working closely with sector professionals. Implications for Rehabilitation Delivery models vary by resources needed for their implementation. Community-based deliver models of hearing aids to children in low-income countries are a cost-effective alternative. The assessment of costs and effects of hearing aids delivery models in low-income countries is possible through planned collaboration between researchers and sector professionals.

  2. development of microcontroller based binaural digital hearing aids

    African Journals Online (AJOL)

    HOD

    but only a small portion of human population seek help and use them [3], though the ... stigma of putting on of digital hearing aid will no longer be there as before. ... 36, No. 3, July 2017 911 aids including the programmability, self-monitoring,.

  3. Relationship between Otolaryngologic Complaints and Systemic Comorbidities Observed in a Group of Hearing Aid Users

    Directory of Open Access Journals (Sweden)

    Ribas, Angela

    2014-11-01

    Full Text Available Introduction Optimization of the selection, adaptation, and benefit of hearing aids is necessary to characterize and manage hearing loss, user expectations, otolaryngologic symptoms, and systemic comorbidities. Objective To compare the occurrence of otologic complaints, systemic diseases, and effective use of hearing aids in men and women with deafness. Methods Patients from a Unified Health System–accredited hearing health service, who reported problems in adapting to their hearing aids, were evaluated by a physician and audiologist. An anamnesis, ENT evaluation, and audiological evaluation were performed. Results During the data collection period, 278 subjects came in for follow-up visits; of these, 61 (21% reported otologic or operational problems with their equipment. The most prevalent type of hearing loss was basocochlear, a characteristic of presbycusis, in both men and women; the most frequently reported comorbidities were hypercholesterolemia (more significant in women and hypertension (more significant in men. Fourteen subjects reported using their device discontinuously, with no significant difference between genders; the reasons for discontinuation of use were itching and ringing, with more complaints from women. Conclusion The incidence of systemic and audiological complaints is high in this population. These patients should be evaluated thoroughly, as resolutions of these complaints can contribute to improving the quality of life and assist in the process of hearing aid fitting.

  4. A Randomized Controlled Trial to Evaluate the Benefits of a Multimedia Educational Program for First-Time Hearing Aid Users

    Science.gov (United States)

    Brandreth, Marian; Brassington, William; Leighton, Paul; Wharrad, Heather

    2016-01-01

    Objectives: The aims of this study were to (1) develop a series of short interactive videos (or reusable learning objects [RLOs]) covering a broad range of practical and psychosocial issues relevant to the auditory rehabilitation for first-time hearing aid users; (2) establish the accessibility, take-up, acceptability and adherence of the RLOs; and (3) assess the benefits and cost-effectiveness of the RLOs. Design: The study was a single-center, prospective, randomized controlled trial with two arms. The intervention group (RLO+, n = 103) received the RLOs plus standard clinical service including hearing aid(s) and counseling, and the waitlist control group (RLO−, n = 100) received standard clinical service only. The effectiveness of the RLOs was assessed 6-weeks posthearing aid fitting. Seven RLOs (total duration 1 hr) were developed using a participatory, community of practice approach involving hearing aid users and audiologists. RLOs included video clips, illustrations, animations, photos, sounds and testimonials, and all were subtitled. RLOs were delivered through DVD for TV (50.6%) and PC (15.2%), or via the internet (32.9%). Results: RLO take-up was 78%. Adherence overall was at least 67%, and 97% in those who attended the 6-week follow-up. Half the participants watched the RLOs two or more times, suggesting self-management of their hearing loss, hearing aids, and communication. The RLOs were rated as highly useful and the majority of participants agreed the RLOs were enjoyable, improved their confidence and were preferable to written information. Postfitting, there was no significant between-group difference in the primary outcome measure, overall hearing aid use. However, there was significantly greater hearing aid use in the RLO+ group for suboptimal users. Furthermore, the RLO+ group had significantly better knowledge of practical and psychosocial issues, and significantly better practical hearing aid skills than the RLO− group. Conclusions: The RLOs

  5. A Randomized Controlled Trial to Evaluate the Benefits of a Multimedia Educational Program for First-Time Hearing Aid Users.

    Science.gov (United States)

    Ferguson, Melanie; Brandreth, Marian; Brassington, William; Leighton, Paul; Wharrad, Heather

    2016-01-01

    The aims of this study were to (1) develop a series of short interactive videos (or reusable learning objects [RLOs]) covering a broad range of practical and psychosocial issues relevant to the auditory rehabilitation for first-time hearing aid users; (2) establish the accessibility, take-up, acceptability and adherence of the RLOs; and (3) assess the benefits and cost-effectiveness of the RLOs. The study was a single-center, prospective, randomized controlled trial with two arms. The intervention group (RLO+, n = 103) received the RLOs plus standard clinical service including hearing aid(s) and counseling, and the waitlist control group (RLO-, n = 100) received standard clinical service only. The effectiveness of the RLOs was assessed 6-weeks posthearing aid fitting. Seven RLOs (total duration 1 hr) were developed using a participatory, community of practice approach involving hearing aid users and audiologists. RLOs included video clips, illustrations, animations, photos, sounds and testimonials, and all were subtitled. RLOs were delivered through DVD for TV (50.6%) and PC (15.2%), or via the internet (32.9%). RLO take-up was 78%. Adherence overall was at least 67%, and 97% in those who attended the 6-week follow-up. Half the participants watched the RLOs two or more times, suggesting self-management of their hearing loss, hearing aids, and communication. The RLOs were rated as highly useful and the majority of participants agreed the RLOs were enjoyable, improved their confidence and were preferable to written information. Postfitting, there was no significant between-group difference in the primary outcome measure, overall hearing aid use. However, there was significantly greater hearing aid use in the RLO+ group for suboptimal users. Furthermore, the RLO+ group had significantly better knowledge of practical and psychosocial issues, and significantly better practical hearing aid skills than the RLO- group. The RLOs were shown to be beneficial to first

  6. Hearing aid patients in private practice and public health (Veterans Affairs) clinics: are they different?

    Science.gov (United States)

    Cox, Robyn M; Alexander, Genevieve C; Gray, Ginger A

    2005-12-01

    In hearing aid research, it is commonplace to combine data across subjects whose hearing aids were provided in different service delivery models. There is reason to question whether these types of patients are always similar enough to justify this practice. To explore this matter, this investigation evaluated similarities and differences in self-report data obtained from hearing aid patients derived from public health (Veterans Affairs, VA) and private practice (PP) settings. The study was a multisite, cross-sectional survey in which 230 hearing aid patients from VA and PP audiology clinic settings provided self-report data on a collection of questionnaires both before and after the hearing aid fitting. Subjects were all older adults with mild to moderately severe hearing loss. About half of them had previous experience wearing hearing aids. All subjects were fitted with wide-dynamic-range-compression instruments and received similar treatment protocols. Numerous statistically significant differences were observed between the VA and PP subject groups. Before the fitting, VA patients reported higher expectations from the hearing aids and more severe unaided problems compared with PP patients with similar audiograms. Three wks after the fitting, VA patients reported more satisfaction with their hearing aids. On some measures VA patients reported more benefit, but different measures of benefit did not give completely consistent results. Both groups reported using the hearing aids an average of approximately 8 hrs per day. VA patients reported age-normal physical and mental health, but PP patients tended to report better than typical health for their age group. These data indicate that hearing aid patients seen in the VA public health hearing services are systematically different in self-report domains from those seen in private practice services. It is therefore risky to casually combine data from these two types of subjects or to generalize research results from one

  7. Hearing aids in children: the importance of the verification and validation processes.

    Science.gov (United States)

    Rissatto, Mara Renata; Novaes, Beatriz Cavalcanti de Albuquerque Caiuby

    2009-01-01

    during the fitting of hearing aids in children it is important, besides using a verification protocol, to have a validation process. to describe and discuss the use of a protocol for the fitting and the verification of hearing aids in children, as well as the impact of the adjustment of the acoustic characteristics in speech perception tasks. ten children aging from three to eleven years were enrolled in this study. All children presented bilateral sensorineural hearing impairment, were users of hearing aids and were followed at a public hearing health care service in Bahia. The children were submitted to the following procedures: pure tone air and bone conduction thresholds; real-ear coupler difference (RECD); verification with real-ear measurement equipment: coupler gain/output and insertion gain and to speech perception tasks: 'The Six-Sound Test' (Ling, 2006) and the 'Word Associations for Syllable Perception' (WASP - Koch, 1999). The programmed electro acoustic characteristics of the hearing aids were compared to the electro acoustic characteristics prescribed by the DSL [i/o] v4.1 software. The speech perception tasks were reapplied on three occasions: straight after the modification of the electro acoustic characteristics, after 30 days and 60 days. for more than 50% of the tested children, the programmed electro acoustic characteristics of the hearing aids did not correspond to that suggested by the DSL [i/o] software. Adequate prescription was verified in 70% of the investigated sample; this was also confirmed by the results in the speech perception tasks (p=0.000). This data confirmed that the mean percentage of correct answers increased after the modification of the electro acoustic characteristics. the use of a protocol that verifies and validates the fitting of hearing aids in children is necessary.

  8. Neural Correlates of Selective Attention With Hearing Aid Use Followed by ReadMyQuips Auditory Training Program.

    Science.gov (United States)

    Rao, Aparna; Rishiq, Dania; Yu, Luodi; Zhang, Yang; Abrams, Harvey

    The objectives of this study were to investigate the effects of hearing aid use and the effectiveness of ReadMyQuips (RMQ), an auditory training program, on speech perception performance and auditory selective attention using electrophysiological measures. RMQ is an audiovisual training program designed to improve speech perception in everyday noisy listening environments. Participants were adults with mild to moderate hearing loss who were first-time hearing aid users. After 4 weeks of hearing aid use, the experimental group completed RMQ training in 4 weeks, and the control group received listening practice on audiobooks during the same period. Cortical late event-related potentials (ERPs) and the Hearing in Noise Test (HINT) were administered at prefitting, pretraining, and post-training to assess effects of hearing aid use and RMQ training. An oddball paradigm allowed tracking of changes in P3a and P3b ERPs to distractors and targets, respectively. Behavioral measures were also obtained while ERPs were recorded from participants. After 4 weeks of hearing aid use but before auditory training, HINT results did not show a statistically significant change, but there was a significant P3a reduction. This reduction in P3a was correlated with improvement in d prime (d') in the selective attention task. Increased P3b amplitudes were also correlated with improvement in d' in the selective attention task. After training, this correlation between P3b and d' remained in the experimental group, but not in the control group. Similarly, HINT testing showed improved speech perception post training only in the experimental group. The criterion calculated in the auditory selective attention task showed a reduction only in the experimental group after training. ERP measures in the auditory selective attention task did not show any changes related to training. Hearing aid use was associated with a decrement in involuntary attention switch to distractors in the auditory selective

  9. Successful bone-anchored hearing aid implantation in a patient with osteogenesis imperfecta.

    Science.gov (United States)

    Coutinho, M B; Marques, C; Mendes, G J; Gonçalves, C

    2015-11-01

    To report a case of successful bone-anchored hearing aid implantation in an adult patient with type III osteogenesis imperfecta, which is commonly regarded as a contraindication to this procedure. A 45-year-old man with type III osteogenesis imperfecta presented with mixed hearing loss. There was a mild sensorineural component in both ears, with an air-bone gap between 45 and 50 dB HL. He was implanted with a bone-anchored hearing aid. The audiological outcome was good, with no complications and good implant stability (as measured by resonance frequency analysis). To our knowledge, this is the first recorded case of bone-anchored hearing aid implantation in a patient with osteogenesis imperfecta.

  10. Electromagnetic interference of bone-anchored hearing aids by cellular phones.

    Science.gov (United States)

    Kompis, M; Negri, S; Häusler, R

    2000-10-01

    We report a case of electromagnetic interference between a bone-anchored hearing aid (BAHA) and a cellular phone. A 54-year-old women was successfully treated for severe mixed conductive and sensorineural hearing loss with a BAHA. Five years after implantation, the patient experienced a sudden feeling of dizziness, accompanied by a loud buzzing sound and by a sensation of head pressure while examining a digital mobile phone. During a subsequent experiment, the buzzing sound could be reproduced and was identified as electromagnetic interference between the BAHA and digital cellular phones. Seventeen adult BAHA users from our clinic participated in a subsequent survey. Of the 13 patients with some experience of digital cellular phones, 11 reported hearing annoying noises elicited by these devices. However, no other sensation, such as dizziness, was described. Owing to the increasing number of users of both hearing aids and cellular phones, the incidence of electromagnetic interference must be expected to increase as well. Although to date there is no evidence that such interference may be harmful or dangerous to users of conventional or bone-anchored hearing aids, unexpected interference can be a frightening experience.

  11. Semi-non-intrusive objective intelligibility measure using spatial filtering in hearing aids

    DEFF Research Database (Denmark)

    Sørensen, Charlotte; Boldt, Jesper Bünsow; Gran, Frederik

    2016-01-01

    -intrusive metrics have not been able to achieve acceptable intelligibility predictions. This paper presents a new semi-non-intrusive intelligibility measure based on an existing intrusive measure, STOI, where an estimate of the clean speech is extracted using spatial filtering in the hearing aid. The results......Reliable non-intrusive online assessment of speech intelligibility can play a key role for the functioning of hearing aids, e.g. as guidance for adjusting the hearing aid settings to the environment. While existing intrusive metrics can provide a precise and reliable measure, the current non...

  12. Dynamic relation between working memory capacity and speech recognition in noise during the first 6 months of hearing aid use.

    Science.gov (United States)

    Ng, Elaine H N; Classon, Elisabet; Larsby, Birgitta; Arlinger, Stig; Lunner, Thomas; Rudner, Mary; Rönnberg, Jerker

    2014-11-23

    The present study aimed to investigate the changing relationship between aided speech recognition and cognitive function during the first 6 months of hearing aid use. Twenty-seven first-time hearing aid users with symmetrical mild to moderate sensorineural hearing loss were recruited. Aided speech recognition thresholds in noise were obtained in the hearing aid fitting session as well as at 3 and 6 months postfitting. Cognitive abilities were assessed using a reading span test, which is a measure of working memory capacity, and a cognitive test battery. Results showed a significant correlation between reading span and speech reception threshold during the hearing aid fitting session. This relation was significantly weakened over the first 6 months of hearing aid use. Multiple regression analysis showed that reading span was the main predictor of speech recognition thresholds in noise when hearing aids were first fitted, but that the pure-tone average hearing threshold was the main predictor 6 months later. One way of explaining the results is that working memory capacity plays a more important role in speech recognition in noise initially rather than after 6 months of use. We propose that new hearing aid users engage working memory capacity to recognize unfamiliar processed speech signals because the phonological form of these signals cannot be automatically matched to phonological representations in long-term memory. As familiarization proceeds, the mismatch effect is alleviated, and the engagement of working memory capacity is reduced. © The Author(s) 2014.

  13. Working memory and intelligibility of hearing-aid processed speech

    Science.gov (United States)

    Souza, Pamela E.; Arehart, Kathryn H.; Shen, Jing; Anderson, Melinda; Kates, James M.

    2015-01-01

    Previous work suggested that individuals with low working memory capacity may be at a disadvantage in adverse listening environments, including situations with background noise or substantial modification of the acoustic signal. This study explored the relationship between patient factors (including working memory capacity) and intelligibility and quality of modified speech for older individuals with sensorineural hearing loss. The modification was created using a combination of hearing aid processing [wide-dynamic range compression (WDRC) and frequency compression (FC)] applied to sentences in multitalker babble. The extent of signal modification was quantified via an envelope fidelity index. We also explored the contribution of components of working memory by including measures of processing speed and executive function. We hypothesized that listeners with low working memory capacity would perform more poorly than those with high working memory capacity across all situations, and would also be differentially affected by high amounts of signal modification. Results showed a significant effect of working memory capacity for speech intelligibility, and an interaction between working memory, amount of hearing loss and signal modification. Signal modification was the major predictor of quality ratings. These data add to the literature on hearing-aid processing and working memory by suggesting that the working memory-intelligibility effects may be related to aggregate signal fidelity, rather than to the specific signal manipulation. They also suggest that for individuals with low working memory capacity, sensorineural loss may be most appropriately addressed with WDRC and/or FC parameters that maintain the fidelity of the signal envelope. PMID:25999874

  14. Working memory and intelligibility of hearing-aid processed speech

    Directory of Open Access Journals (Sweden)

    Pamela eSouza

    2015-05-01

    Full Text Available Previous work suggested that individuals with low working memory capacity may be at a disadvantage in adverse listening environments, including situations with background noise or substantial modification of the acoustic signal. This study explored the relationship between patient factors (including working memory capacity and intelligibility and quality of modified speech for older individuals with sensorineural hearing loss. The modification was created using a combination of hearing aid processing (wide-dynamic range compression and frequency compression applied to sentences in multitalker babble. The extent of signal modification was quantified via an envelope fidelity index. We also explored the contribution of components of working memory by including measures of processing speed and executive function. We hypothesized that listeners with low working memory capacity would perform more poorly than those with high working memory capacity across all situations, and would also be differentially affected by high amounts of signal modification. Results showed a significant effect of working memory capacity for speech intelligibility, and an interaction between working memory, amount of hearing loss and signal modification. Signal modification was the major predictor of quality ratings. These data add to the literature on hearing-aid processing and working memory by suggesting that the working memory-intelligibility effects may be related to aggregate signal fidelity, rather than on the specific signal manipulation. They also suggest that for individuals with low working memory capacity, sensorineural loss may be most appropriately addressed with wide-dynamic range compression and/or frequency compression parameters that maintain the fidelity of the signal envelope.

  15. A Qualitative Case Study of Smartphone-Connected Hearing Aids: Influences on Patients, Clinicians, and Patient-Clinician Interactions.

    Science.gov (United States)

    Ng, Stella L; Phelan, Shanon; Leonard, MaryAnn; Galster, Jason

    2017-06-01

    patients' perceptions of themselves as technologically competent or incompetent, and descriptions of how they learned to use the new technology. Between cases, the study found a difference in the response to how the connected hearing aid changed the clinician-patient relationship. While clinicians valued the increased time they spent "getting to know" their patients, patients experienced some frustration specific to the additional troubleshooting related to Bluetooth connectivity. Across cases, there was a resounding theme of "normalization" of hearing aids via their integration with a "normal" technology (mobile phones) and general lack of concern about privacy in relation to the smartphone application and its tracking and geotagging features. Both audiologists and patients credited the connected hearing aids with increased opportunities to participate more fully in everyday life. The introduction of smartphone-connected hearing aids influenced the identities and candidate profiles of hearing aid users, and the nature of time spent in clinical interactions, in important and interesting ways. The influence of connected hearing aids on patient experience and audiology practice calls for continued research and clinical consideration, with implications for clinical decision-making regarding hearing aid candidacy. Further study should look critically at normalization and possible unintended stigmatizing effects of making hearing aids increasingly discreet. American Academy of Audiology

  16. The impact of hearing aids and age-related hearing loss on auditory plasticity across three months - An electrical neuroimaging study.

    Science.gov (United States)

    Giroud, Nathalie; Lemke, Ulrike; Reich, Philip; Matthes, Katarina L; Meyer, Martin

    2017-09-01

    The present study investigates behavioral and electrophysiological auditory and cognitive-related plasticity in three groups of healthy older adults (60-77 years). Group 1 was moderately hearing-impaired, experienced hearing aid users, and fitted with new hearing aids using non-linear frequency compression (NLFC on); Group 2, also moderately hearing-impaired, used the same type of hearing aids but NLFC was switched off during the entire period of study duration (NLFC off); Group 3 represented individuals with age-appropriate hearing (NHO) as controls, who were not different in IQ, gender, or age from Group 1 and 2. At five measurement time points (M1-M5) across three months, a series of active oddball tasks were administered while EEG was recorded. The stimuli comprised syllables consisting of naturally high-pitched fricatives (/sh/, /s/, and /f/), which are hard to distinguish for individuals with presbycusis. By applying a data-driven microstate approach to obtain global field power (GFP) as a measure of processing effort, the modulations of perceptual (P50, N1, P2) and cognitive-related (N2b, P3b) auditory evoked potentials were calculated and subsequently related to behavioral changes (accuracy and reaction time) across time. All groups improved their performance across time, but NHO showed consistently higher accuracy and faster reaction times than the hearing-impaired groups, especially under difficult conditions. Electrophysiological results complemented this finding by demonstrating longer latencies in the P50 and the N1 peak in hearing aid users. Furthermore, the GFP of cognitive-related evoked potentials decreased from M1 to M2 in the NHO group, while a comparable decrease in the hearing-impaired group was only evident at M5. After twelve weeks of hearing aid use of eight hours each day, we found a significantly lower GFP in the P3b of the group with NLFC on as compared to the group with NLFC off. These findings suggest higher processing effort, as

  17. Factors that influence intent to adopt a hearing aid among older people in Italy.

    Science.gov (United States)

    Cobelli, Nicola; Gill, Liz; Cassia, Fabio; Ugolini, Marta

    2014-11-01

    Hearing loss is one of the most prevalent health impairments associated with ageing in developed countries, and it can result in social, emotional and communication dysfunction. Hearing loss in Italy is increasing, yet, despite the availability of free hearing aids and access to qualified community-based health professionals specialising in audiology services, their uptake remains low (about 15%-20%). This paper presents an investigation of the possible reasons why older people in Italy resist adopting a hearing aid. We used the literature to identify factors influencing people with hearing loss's decision-making, and drew on the theory of reasoned action to create an explanatory model. To test our hypotheses, we applied a cross-sectional design. We developed a questionnaire including 13 items related to adopting a hearing aid. Health professionals identified 400 persons aged 60-90 who were candidates for a free hearing aid. Those willing to participate were sent a copy of the questionnaire and telephoned between August and September 2009; a total of 243 responded (response rate of 60.8%). Linear regression analysis highlighted that a person's intention to adopt a hearing aid was positively related to their attitude towards its adoption, but negatively linked to their perceived subjective norms. It was found that trust in the health professional does not moderate the relationship between a person's attitude and their intention to adopt a hearing aid, but trust mitigates the relationship between a person's perceived subjective norms and their intentions. These findings underline the importance of the potential role that the healthcare professional could play in reducing the uncertainty created by external social pressures. For this purpose, stronger collaboration between the various health professionals involved in hearing aid provision, from diagnosis to fitting, is recommended. © 2014 John Wiley & Sons Ltd.

  18. Vibrant Soundbridge and Bone Conduction Hearing Aid in Patients with Bilateral Malformation of External Ear

    Directory of Open Access Journals (Sweden)

    Mondelli, Maria Fernanda Capoani Garcia

    2015-10-01

    Full Text Available Introduction Hearing loss is the most common clinical finding in patients with malformation of the external ear canal. Among the possibilities of treatment, there is the adaptation of hearing aids by bone conduction and the adaptation of implantable hearing aids. Objective To assess speech perception with the use of Vibrant Soundbridge (VBS - MED-EL, Innsbruck, Austria associated with additional amplification in patients with bilateral craniofacial malformation. Method We evaluated 11 patients with bilateral malformation over 12 years with mixed hearing loss or bilateral conductive. They were using the Softband (Oticon Medical, Sweden and bone conduction hearing aid in the ear opposite the one with the VSB. We performed the evaluation of speech perception using the Hearing in Noise Test. Results Participants were eight men and three women with a mean of 19.5 years. The signal / noise ratio presented significant results in patients fitted with VSB and bone conduction hearing aid. Conclusion The results of speech perception were significantly better with use of VBS combined with bone conduction hearing aids.

  19. Effects of sound amplification in self-perception of tinnitus and hearing loss in the elderly

    Directory of Open Access Journals (Sweden)

    Tiago de Melo Araujo

    Full Text Available ABSTRACT OBJECTIVE: To determine the effect of the use of hearing aids in self-perception of tinnitus and hearing loss in the elderly. METHODS: A total of 24 elderly patients between 60 and 70 years of age with moderate-grade sensorineural hearing loss were evaluated and divided into two groups according to the presence or absence of tinnitus. All volunteers were fitted with binaural micro-channel hearing aids of the same brand and model and submitted to tests, scales, and questionnaires relevant to this topic. The evaluations were performed before and after one and three months of effective use of these hearing aids. RESULTS: Acoustic stimulation through the effective use of hearing aids caused a reduction in the perception of tinnitus sound intensity (especially in evaluations with the prosthesis on and in nuisance associated with this symptom and with hearing loss. In addition, all participants were satisfied with the use of hearing aids. CONCLUSION: The continuous use of hearing aids is beneficial for the treatment of tinnitus and hearing loss, bringing satisfaction to users.

  20. FPGA implementation of adaptive beamforming in hearing aids.

    Science.gov (United States)

    Samtani, Kartik; Thomas, Jobin; Varma, G Abhinav; Sumam, David S; Deepu, S P

    2017-07-01

    Beamforming is a spatial filtering technique used in hearing aids to improve target sound reception by reducing interference from other directions. In this paper we propose improvements in an existing architecture present for two omnidirectional microphone array based adaptive beamforming for hearing aid applications and implement the same on Xilinx Artix 7 FPGA using VHDL coding and Xilinx Vivado ® 2015.2. The nulls are introduced in particular directions by combination of two fixed polar patterns. This combination can be adaptively controlled to steer the null in the direction of noise. The beamform patterns and improvements in SNR values obtained from experiments in a conference room environment are analyzed.

  1. Self-reported outcomes of aural rehabilitation for adult hearing aid users in a developing South African context

    Directory of Open Access Journals (Sweden)

    Elaine Pienaar

    2010-12-01

    Full Text Available Hearing impairment has far reaching consequences for affected individuals, in terms of quality of life indicators. In a developing South African context the hearing impaired population is faced with limited aural rehabilitation services. This study evaluated self-reported outcomes of aural rehabilitation in a group of adults in the public healthcare sector with a standardized outcomes measurement tool (IOI-HA. Sixty-one respondents participated (44% males; 56% females, with a mean age of 69.7 years. Results revealed that the majority of respondents experienced favourable outcomes in all domains of the inventory comprising of: daily use of hearing aids, benefits provided by hearing aids, residual activity limitation, satisfaction with hearing aids, residual participation restriction, impact of hearing difficulties on others, and changes in quality of life. Statistically significant relationships were obtained between the daily use of hearing aids, the degree of hearing loss, and the type of hearing aids fitted, as well as the benefits received from hearing aids in difficult listening environments (p < 0.05. Despite challenges of developing contexts, the mean scores distribution compared positively to similar reports from developed countries. Outcomes of improved quality of life emphasize the importance of providing affordable hearing aids and services to all hearing impaired individuals in South Africa.

  2. A New Probe Noise Approach For Acoustic Feedback Cancellation In Hearing Aids

    DEFF Research Database (Denmark)

    Guo, Meng; Jensen, Søren Holdt; Jensen, Jesper

    Acoustic feedback is a big challenge in hearing aids. If not appropriately treated, the feedback limits the maximum possible amplification and may lead to significant sound distortions. In a state-of-the-art hearing aid, an acoustic feedback cancellation (AFC) system is used to compensate...

  3. Perception-Based Personalization of Hearing Aids Using Gaussian Processes and Active Learning

    DEFF Research Database (Denmark)

    Nielsen, Jens Brehm; Nielsen, Jakob; Larsen, Jan

    2015-01-01

    Personalization of multi-parameter hearing aids involves an initial fitting followed by a manual knowledge-based trial-and-error fine-tuning from ambiguous verbal user feedback. The result is an often suboptimal HA setting whereby the full potential of modern hearing aids is not utilized. This ar...

  4. Evaluation of the International Outcome Inventory for Hearing Aids in a veteran sample.

    Science.gov (United States)

    Smith, Sherri L; Noe, Colleen M; Alexander, Genevieve C

    2009-06-01

    The International Outcome Inventory for Hearing Aids (IOI-HA) was developed as a global hearing aid outcome measure targeting seven outcome domains. The published norms were based on a private-pay sample who were fitted with analog hearing aids. The purpose of this study was to evaluate the psychometric properties of the IOI-HA and to establish normative data in a veteran sample. Survey. The participants were 131 male veterans (mean age of 74.3 years, SD = 7.4) who were issued hearing aids with digital signal processing (DSP). Hearing aids with DSP that were fitted bilaterally between 2005 and 2007. Veterans were mailed two copies of the IOI-HA. The participants were instructed to complete the first copy of the questionnaire immediately and the second copy in two weeks. The completed questionnaires were mailed to the laboratory. The psychometric properties of the questionnaire were evaluated. As suggested by Cox and colleagues, the participants were divided into two categories based on their unaided subjective hearing difficulty. The two categories were (1) those with less hearing difficulty (none-to-moderate category) and (2) those who report more hearing difficulty (moderately severe+ category). The norms from the current veteran sample then were compared to the original, published sample. For each hearing difficulty category, the critical difference values were calculated for each item and for the total score. A factor analysis showed that the IOI-HA in the veteran sample had the identical subscale structure as reported in the original sample. For the total scale, the internal consistency was good (Chronbach's alpha = 0.83), and the test-retest reliability was high (lambda = 0.94). Group and individual norms were developed for both hearing difficulty categories in the veteran sample. For each IOI-HA item, the critical difference scores were one response unit between two test sessions reflects a true change in outcome for a given domain. The results of this study

  5. Hearing aid noise suppression and working memory function

    OpenAIRE

    Fischer, Rosa-Linde; Neher, Tobias; Wagener, Kirsten C.

    2017-01-01

    OBJECTIVE: Research findings concerning the relation between benefit from hearing aid (HA) noise suppression and working memory function are inconsistent. The current study thus investigated the effects of three noise suppression algorithms on auditory working memory and the relation with reading span.DESIGN: Using a computer simulation of bilaterally fitted HAs, four settings were tested: (1) unprocessed, (2) directional microphones, (3) single-channel noise reduction and (4) binaural cohere...

  6. Neurodynamic evaluation of hearing aid features using EEG correlates of listening effort.

    Science.gov (United States)

    Bernarding, Corinna; Strauss, Daniel J; Hannemann, Ronny; Seidler, Harald; Corona-Strauss, Farah I

    2017-06-01

    In this study, we propose a novel estimate of listening effort using electroencephalographic data. This method is a translation of our past findings, gained from the evoked electroencephalographic activity, to the oscillatory EEG activity. To test this technique, electroencephalographic data from experienced hearing aid users with moderate hearing loss were recorded, wearing hearing aids. The investigated hearing aid settings were: a directional microphone combined with a noise reduction algorithm in a medium and a strong setting, the noise reduction setting turned off, and a setting using omnidirectional microphones without any noise reduction. The results suggest that the electroencephalographic estimate of listening effort seems to be a useful tool to map the exerted effort of the participants. In addition, the results indicate that a directional processing mode can reduce the listening effort in multitalker listening situations.

  7. Acoustical and Perceptual Comparison of Noise Reduction and Compression in Hearing Aids

    NARCIS (Netherlands)

    Brons, Inge; Houben, Rolph; Dreschler, Wouter A.

    2015-01-01

    Noise reduction and dynamic-range compression are generally applied together in hearing aids but may have opposite effects on amplification. This study evaluated the acoustical and perceptual effects of separate and combined processing of noise reduction and compression. Recordings of the output of

  8. Combination of Adaptive Feedback Cancellation and Binaural Adaptive Filtering in Hearing Aids

    Directory of Open Access Journals (Sweden)

    Anthony Lombard

    2009-01-01

    Full Text Available We study a system combining adaptive feedback cancellation and adaptive filtering connecting inputs from both ears for signal enhancement in hearing aids. For the first time, such a binaural system is analyzed in terms of system stability, convergence of the algorithms, and possible interaction effects. As major outcomes of this study, a new stability condition adapted to the considered binaural scenario is presented, some already existing and commonly used feedback cancellation performance measures for the unilateral case are adapted to the binaural case, and possible interaction effects between the algorithms are identified. For illustration purposes, a blind source separation algorithm has been chosen as an example for adaptive binaural spatial filtering. Experimental results for binaural hearing aids confirm the theoretical findings and the validity of the new measures.

  9. On the dynamics of the preference-performance relation for hearing aid noise reduction

    DEFF Research Database (Denmark)

    Fischer, Rosa-Linde; Wagener, Kirsten C.; Vormann, Matthias

    on the data collected during the first laboratory assessment of the study. In particular, the influence of hearing aid experience and individual noise sensitivity on the preference-performance relation will be presented and discussed. REFERENCES S. Getzmann, E. Wascher and M. Falkenstein (2015). "What does......Previous research has shown that hearing aid users can differ substantially in their preference for noise reduction (NR) strength, and that preference for and speech recognition with NR processing typically are not correlated (e.g. Neher 2014; Serman et al. 2016). In other words, hearing aid users...... may prefer a certain NR setting, but perform better with a different one. The aim of the present work was to investigate the influence of individual noise sensitivity, hearing aid experience and acclimatization on the preference-performance relation for different NR settings. For this purpose...

  10. Speech perception benefits of FM and infrared devices to children with hearing aids in a typical classroom.

    Science.gov (United States)

    Anderson, Karen L; Goldstein, Howard

    2004-04-01

    Children typically learn in classroom environments that have background noise and reverberation that interfere with accurate speech perception. Amplification technology can enhance the speech perception of students who are hard of hearing. This study used a single-subject alternating treatments design to compare the speech recognition abilities of children who are, hard of hearing when they were using hearing aids with each of three frequency modulated (FM) or infrared devices. Eight 9-12-year-olds with mild to severe hearing loss repeated Hearing in Noise Test (HINT) sentence lists under controlled conditions in a typical kindergarten classroom with a background noise level of +10 dB signal-to-noise (S/N) ratio and 1.1 s reverberation time. Participants listened to HINT lists using hearing aids alone and hearing aids in combination with three types of S/N-enhancing devices that are currently used in mainstream classrooms: (a) FM systems linked to personal hearing aids, (b) infrared sound field systems with speakers placed throughout the classroom, and (c) desktop personal sound field FM systems. The infrared ceiling sound field system did not provide benefit beyond that provided by hearing aids alone. Desktop and personal FM systems in combination with personal hearing aids provided substantial improvements in speech recognition. This information can assist in making S/N-enhancing device decisions for students using hearing aids. In a reverberant and noisy classroom setting, classroom sound field devices are not beneficial to speech perception for students with hearing aids, whereas either personal FM or desktop sound field systems provide listening benefits.

  11. Computational reduction techniques for numerical vibro-acoustic analysis of hearing aids

    DEFF Research Database (Denmark)

    Creixell Mediante, Ester

    . In this thesis, several challenges encountered in the process of modelling and optimizing hearing aids are addressed. Firstly, a strategy for modelling the contacts between plastic parts for harmonic analysis is developed. Irregularities in the contact surfaces, inherent to the manufacturing process of the parts....... Secondly, the applicability of Model Order Reduction (MOR) techniques to lower the computational complexity of hearing aid vibro-acoustic models is studied. For fine frequency response calculation and optimization, which require solving the numerical model repeatedly, a computational challenge...... is encountered due to the large number of Degrees of Freedom (DOFs) needed to represent the complexity of the hearing aid system accurately. In this context, several MOR techniques are discussed, and an adaptive reduction method for vibro-acoustic optimization problems is developed as a main contribution. Lastly...

  12. A comparison of sound quality judgments for monaural and binaural hearing aid processed stimuli.

    Science.gov (United States)

    Balfour, P B; Hawkins, D B

    1992-10-01

    Fifteen adults with bilaterally symmetrical mild and/or moderate sensorineural hearing loss completed a paired-comparison task designed to elicit sound quality preference judgments for monaural/binaural hearing aid processed signals. Three stimuli (speech-in-quiet, speech-in-noise, and music) were recorded separately in three listening environments (audiometric test booth, living room, and a music/lecture hall) through hearing aids placed on a Knowles Electronics Manikin for Acoustics Research. Judgments were made on eight separate sound quality dimensions (brightness, clarity, fullness, loudness, nearness, overall impression, smoothness, and spaciousness) for each of the three stimuli in three listening environments. Results revealed a distinct binaural preference for all eight sound quality dimensions independent of listening environment. Binaural preferences were strongest for overall impression, fullness, and spaciousness. Stimulus type effect was significant only for fullness and spaciousness, where binaural preferences were strongest for speech-in-quiet. After binaural preference data were obtained, subjects ranked each sound quality dimension with respect to its importance for binaural listening relative to monaural. Clarity was ranked highest in importance and brightness was ranked least important. The key to demonstration of improved binaural hearing aid sound quality may be the use of a paired-comparison format.

  13. Differences in speech processing among elderly hearing-impaired listeners with or without hearing aid experience: Eye-tracking and fMRI measurements

    DEFF Research Database (Denmark)

    Habicht, Julia; Behler, Oliver; Kollmeier, Birger

    2017-01-01

    In contrast to the effects of hearing loss, the effects of hearing aid (HA) experience on speech-in-noise (SIN) processing are underexplored. Using an eye-tracking paradigm that allows determining how fast a participant can grasp the meaning of a sentence presented in noise together with two pict...... support the idea that HA experience positively influences the ability to process SIN quickly and that it reduces the recruitment of brain regions outside the core speech-comprehension network....

  14. Towards Cognizant Hearing Aids: Modeling of Content, Affect and Attention

    DEFF Research Database (Denmark)

    Karadogan, Seliz

    Hearing aids improved significantly after the integration of advanced digital signal processing applications. This improvement will continue and evolve through obtaining intelligent, individualized hearing aids integrating top-down (knowledge-based) and bottom-up (signal-based) approaches by making...... use of research done within cognitive science that is the interdisciplinary study of mind and intelligence bringing together various disciplines including Artificial Intelligence, Cognitive Psychology, and Neuroscience. This thesis focuses on three subjects within cognitive science related to hearing...... attention is studied. A computational top-down attention model is presented and behavioral experiments are carried out to investigate the role of top-down task driven attention in the cocktail party problem. Finally, automatic emotion recognition from speech is studied using a dimensional approach...

  15. Open ear hearing aids in tinnitus therapy: An efficacy comparison with sound generators.

    Science.gov (United States)

    Parazzini, Marta; Del Bo, Luca; Jastreboff, Margaret; Tognola, Gabriella; Ravazzani, Paolo

    2011-08-01

    This study aimed to compare the effectiveness of tinnitus retraining therapy (TRT) with sound generators or with open ear hearing aids in the rehabilitation of tinnitus for a group of subjects who, according to Jastreboff categories, can be treated with both approaches to sound therapy (borderline of Category 1 and 2). This study was a prospective data collection with a parallel-group design which entailed that each subject was randomly assigned to one of the two treatments group: half of the subjects were fitted binaurally with sound generators, and the other half with open ear hearing aids. Both groups received the same educational counselling sessions. Ninety-one subjects passed the screening criteria and were enrolled into the study. Structured interviews, with a variety of measures evaluated through the use of visual-analog scales and the tinnitus handicap inventory self-administered questionnaire, were performed before the therapy and at 3, 6, and 12 months during the therapy. Data showed a highly significant improvement in both tinnitus treatments starting from the first three months and up to one year of therapy, with a progressive and statistically significant decrease in the disability every three months. TRT was equally effective with sound generator or open ear hearing aids: they gave basically identical, statistically indistinguishable results.

  16. A critical review of hearing-aid single-microphone noise-reduction studies in adults and children.

    Science.gov (United States)

    Chong, Foong Yen; Jenstad, Lorienne M

    2017-10-26

    Single-microphone noise reduction (SMNR) is implemented in hearing aids to suppress background noise. The purpose of this article was to provide a critical review of peer-reviewed studies in adults and children with sensorineural hearing loss who were fitted with hearing aids incorporating SMNR. Articles published between 2000 and 2016 were searched in PUBMED and EBSCO databases. Thirty-two articles were included in the final review. Most studies with adult participants showed that SMNR has no effect on speech intelligibility. Positive results were reported for acceptance of background noise, preference, and listening effort. Studies of school-aged children were consistent with the findings of adult studies. No study with infants or young children of under 5 years old was found. Recent studies on noise-reduction systems not yet available in wearable hearing aids have documented benefits of noise reduction on memory for speech processing for older adults. This evidence supports the use of SMNR for adults and school-aged children when the aim is to improve listening comfort or reduce listening effort. Future research should test SMNR with infants and children who are younger than 5 years of age. Further development, testing, and clinical trials should be carried out on algorithms not yet available in wearable hearing aids. Testing higher cognitive level for speech processing and learning of novel sounds or words could show benefits of advanced signal processing features. These approaches should be expanded to other populations such as children and younger adults. Implications for rehabilitation The review provides a quick reference for students and clinicians regarding the efficacy and effectiveness of SMNR in wearable hearing aids. This information is useful during counseling session to build a realistic expectation among hearing aid users. Most studies in the adult population suggest that SMNR may provide some benefits to adult listeners in terms of listening

  17. Self-Fitting Hearing Aids: Status Quo and Future Predictions.

    Science.gov (United States)

    Keidser, Gitte; Convery, Elizabeth

    2016-04-12

    A self-contained, self-fitting hearing aid (SFHA) is a device that enables the user to perform both threshold measurements leading to a prescribed hearing aid setting and fine-tuning, without the need for audiological support or access to other equipment. The SFHA has been proposed as a potential solution to address unmet hearing health care in developing countries and remote locations in the developed world and is considered a means to lower cost and increase uptake of hearing aids in developed countries. This article reviews the status of the SFHA and the evidence for its feasibility and challenges and predicts where it is heading. Devices that can be considered partly or fully self-fitting without audiological support were identified in the direct-to-consumer market. None of these devices are considered self-contained as they require access to other hardware such as a proprietary interface, computer, smartphone, or tablet for manipulation. While there is evidence that self-administered fitting processes can provide valid and reliable results, their success relies on user-friendly device designs and interfaces and easy-to-interpret instructions. Until these issues have been sufficiently addressed, optional assistance with the self-fitting process and on-going use of SFHAs is recommended. Affordability and a sustainable delivery system remain additional challenges for the SFHA in developing countries. Future predictions include a growth in self-fitting products, with most future SFHAs consisting of earpieces that connect wirelessly with a smartphone and providers offering assistance through a telehealth infrastructure, and the integration of SFHAs into the traditional hearing health-care model. © The Author(s) 2016.

  18. Consumer preferences for hearing aid attributes: a comparison of rating and conjoint analysis methods.

    Science.gov (United States)

    Bridges, John F P; Lataille, Angela T; Buttorff, Christine; White, Sharon; Niparko, John K

    2012-03-01

    Low utilization of hearing aids has drawn increased attention to the study of consumer preferences using both simple ratings (e.g., Likert scale) and conjoint analyses, but these two approaches often produce inconsistent results. The study aims to directly compare Likert scales and conjoint analysis in identifying important attributes associated with hearing aids among those with hearing loss. Seven attributes of hearing aids were identified through qualitative research: performance in quiet settings, comfort, feedback, frequency of battery replacement, purchase price, water and sweat resistance, and performance in noisy settings. The preferences of 75 outpatients with hearing loss were measured with both a 5-point Likert scale and with 8 paired-comparison conjoint tasks (the latter being analyzed using OLS [ordinary least squares] and logistic regression). Results were compared by examining implied willingness-to-pay and Pearson's Rho. A total of 56 respondents (75%) provided complete responses. Two thirds of respondents were male, most had sensorineural hearing loss, and most were older than 50; 44% of respondents had never used a hearing aid. Both methods identified improved performance in noisy settings as the most valued attribute. Respondents were twice as likely to buy a hearing aid with better functionality in noisy environments (p < .001), and willingness to pay for this attribute ranged from US$2674 on the Likert to US$9000 in the conjoint analysis. The authors find a high level of concordance between the methods-a result that is in stark contrast with previous research. The authors conclude that their result stems from constraining the levels on the Likert scale.

  19. Atitudes frente às próteses auditivas Attitudes towards hearing aids

    Directory of Open Access Journals (Sweden)

    Bárbara Guimarães Bastos

    2009-01-01

    Full Text Available OBJETIVOS: avaliar as atitudes frente à deficiência auditiva e o aparelho de amplificação sonora individual (AASI em candidatos e usuários destes dispositivos. Verificar se existe relação entre tais atitudes e os dados demográficos, audiométricos e características do AASI. MÉTODOS: 63 indivíduos (35 homens e 28 mulheres, idade média de 64,3 anos com deficiência auditiva neurossensorial bilateral de diferentes graus, candidatos e usuários de AASI responderam o "Questionário de Atitudes Frente à Deficiência Auditiva" (ALHQ v3.0. Foi analisada a distribuição da pontuação das subescalas do ALHQ e realizada a correlação entre estas e os dados demográficos, audiológicos e da adaptação do AASI dos participantes. Foram também realizadas comparações da pontuação do ALHQ entre os grupos de candidatos e usuários, entre homens e mulheres. RESULTADOS: não houve distribuição normal das respostas nas subescalas do ALHQ. Não houve correlações entre a pontuação do ALHQ com os dados demográficos e audiológicos. Foram verificadas correlações fracas e significativas entre as subescalas do questionário: "estratégias negativas" e "estima" (rho=-0,39, "negação" e "estima" (rho=-0,27, "estratégias negativas" e "associações negativas" (rho=0,25 e "negação" e "estratégias negativas" (rho=-0,30. Houve diferença significativa nas subescalas estratégias negativas (p=0,02 e associações negativas (p=0,00 entre o grupo de candidatos e usuários. Não houve diferença na pontuação entre homens e mulheres. CONCLUSÃO: a existência de atitudes negativas frente à deficiência auditiva e ao uso do AASI reforça a necessidade do aconselhamento de ajuste pessoal incluído no processo de adaptação do AASI em adultos e idosos. É necessário validar o questionário traduzido para o português brasileiro.PURPOSE: to evaluate the attitudes towards hearing loss and hearing aids in a group of hearing aid candidates and users

  20. Application of the Consumer Decision-Making Model to Hearing Aid Adoption in First-Time Users.

    Science.gov (United States)

    Amlani, Amyn M

    2016-05-01

    Since 1980, hearing aid adoption rates have remained essentially the same, increasing at a rate equal to the organic growth of the population. Researchers have used theoretical models from psychology and sociology to determine those factors or constructs that lead to the adoption of hearing aids by first-time impaired listeners entering the market. In this article, a theoretical model, the Consumer Decision-Making Model (CDM), premised on the neobehavioral approach that considers an individual's psychological and cognitive emphasis toward a product or service, is described. Three theoretical models (i.e., transtheoretical, social model of disability, Health Belief Model), and their relevant findings to the hearing aid market, are initially described. The CDM is then presented, along with supporting evidence of the model's various factors from the hearing aid literature. Future applications of the CDM to hearing health care also are discussed.

  1. Development of a multimedia educational programme for first-time hearing aid users: a participatory design.

    Science.gov (United States)

    Ferguson, Melanie; Leighton, Paul; Brandreth, Marian; Wharrad, Heather

    2018-05-02

    To develop content for a series of interactive video tutorials (or reusable learning objects, RLOs) for first-time adult hearing aid users, to enhance knowledge of hearing aids and communication. RLO content was based on an electronically-delivered Delphi review, workshops, and iterative peer-review and feedback using a mixed-methods participatory approach. An expert panel of 33 hearing healthcare professionals, and workshops involving 32 hearing aid users and 11 audiologists. This ensured that social, emotional and practical experiences of the end-user alongside clinical validity were captured. Content for evidence-based, self-contained RLOs based on pedagogical principles was developed for delivery via DVD for television, PC or internet. Content was developed based on Delphi review statements about essential information that reached consensus (≥90%), visual representations of relevant concepts relating to hearing aids and communication, and iterative peer-review and feedback of content. This participatory approach recognises and involves key stakeholders in the design process to create content for a user-friendly multimedia educational intervention, to supplement the clinical management of first-time hearing aid users. We propose participatory methodologies are used in the development of content for e-learning interventions in hearing-related research and clinical practice.

  2. Comparison of phonological awareness between children with cochlear implants and children with hearing aids

    Directory of Open Access Journals (Sweden)

    Farzad Weisi

    2013-02-01

    Full Text Available Introduction: Advanced phonological skills are important for the acquisition of reading skills. Children with hearing impairment have reading skills are weaker than others because of auditory inputs and due to the defect in phonological skills. The use of hearing aids and cochlear implants help to collect information on people who are hard of hearing.Material and Methods: This descriptive - analytic study was done on 12 children with cochlear implant and 12 children with hearing aids that was selected from second grades students of Tehran primary schools. Children's phonological performance was assessed by phonological subtests of Nama reading test and the data were analyzed using SPSS 16.Results: The results showed that the means of scores of children with cochlear implants in Rhyme task were significantly greater than the children with hearing aids (P=0.034. But in means of scores of Phone deletion and Nonword reading tasks were not significant different between two groups (P=0.919, P=0.670.Discussion: Cochlear implant with accessibility auditory inputs can facilitated the acquisition of phonological awareness skills in hearing loss children. But whereas the other language inputs such as sight and touch input helped to developing these skills, children with hearing aids too also can acquisition these skills.

  3. A Compact and Low-Cost MEMS Loudspeaker for Digital Hearing Aids.

    Science.gov (United States)

    Sang-Soo Je; Rivas, F; Diaz, R E; Jiuk Kwon; Jeonghwan Kim; Bakkaloglu, B; Kiaei, S; Junseok Chae

    2009-10-01

    A microelectromechanical-systems (MEMS)-based electromagnetically actuated loudspeaker to reduce form factor, cost, and power consumption, and increase energy efficiency in hearing-aid applications is presented. The MEMS loudspeaker has multilayer copper coils, an NiFe soft magnet on a thin polyimide diaphragm, and an NdFeB permanent magnet on the perimeter. The coil impedance is measured at 1.5 Omega, and the resonant frequency of the diaphragm is located far from the audio frequency range. The device is driven by a power-scalable, 0.25-mum complementary metal-oxide semiconductor class-D SigmaDelta amplifier stage. The class-D amplifier is formed by a differential H-bridge driven by a single bit, pulse-density-modulated SigmaDelta bitstream at a 1.2-MHz clock rate. The fabricated MEMS loudspeaker generates more than 0.8-mum displacement, equivalent to 106-dB sound pressure level (SPL), with 0.13-mW power consumption. Driven by the SigmaDelta class-D amplifier, the MEMS loudspeaker achieves measured 65-dB total harmonic distortion (THD) with a measurement uncertainty of less than 10%. Energy-efficient and cost-effective advanced hearing aids would benefit from further miniaturization via MEMS technology. The results from this study appear very promising for developing a compact, mass-producible, low-power loudspeaker with sufficient sound generation for hearing-aid applications.

  4. A comparative study of hearing aids and round window application of the vibrant sound bridge (VSB) for patients with mixed or conductive hearing loss.

    Science.gov (United States)

    Marino, Roberta; Linton, Nicola; Eikelboom, Robert H; Statham, Elle; Rajan, Gunesh P

    2013-04-01

    This study was undertaken to determine the efficacy of the round window (RW) application of the vibrant soundbridge (VSB) in patients with mixed or conductive hearing loss. Speech in quiet and in noise were compared to preoperative data attained with conventional hearing aids so that each subject served as his or her own control in a single test protocol. Eighteen adults implanted monaurally with the VSB in the poorer hearing ear. Experience with the VSB ranged from nine to 25 months. Sixteen of the 18 subjects were successful VSB users, wearing their device all waking hours. There was no significant deterioration in the averaged bone conduction results preoperatively versus post-operatively (p>0.05). Speech recognition in quiet results were not significantly different to performance attained whilst wearing hearing aids (p>0.05). Speech recognition in noise performance was substantially improved with use of the VSB in most test conditions. For the majority of the subjects, the VSB was an effective method of hearing restoration for their mixed and conductive hearing loss.

  5. Using a reflection model for modeling the dynamic feedback path of digital hearing aids

    DEFF Research Database (Denmark)

    Ma, Guilin; Gran, Fredrik; Jacobsen, Finn

    2010-01-01

    Feedback whistling is one of the severe problems with hearing aids, especially in dynamic situations when the users hug, pick up a telephone, etc. This paper investigates the properties of the dynamic feedback paths of digital hearing aids and proposes a model based on a reflection assumption...... gain. The method is also extended to dual-microphone hearing aids to assess the possibility of relating the two dynamic feedback paths through the reflection model. However, it is found that in a complicated acoustic environment, the relation between the two feedback paths can be very intricate...

  6. Cognitive skills and the effect of noise on perceived effort in employees with aided hearing impairment and normal hearing

    Directory of Open Access Journals (Sweden)

    Håkan Hua

    2014-01-01

    Full Text Available The aim of the following study was to examine the relationship between working memory capacity (WMC, executive functions (EFs and perceived effort (PE after completing a work-related task in quiet and in noise in employees with aided hearing impairment (HI and normal hearing. The study sample consisted of 20 hearing-impaired and 20 normally hearing participants. Measures of hearing ability, WMC and EFs were tested prior to performing a work-related task in quiet and in simulated traffic noise. PE of the work-related task was also measured. Analysis of variance was used to analyze within- and between-group differences in cognitive skills, performance on the work-related task and PE. The presence of noise yielded a significantly higher PE for both groups. However, no significant group differences were observed in WMC, EFs, PE and performance in the work-related task. Interestingly, significant negative correlations were only found between PE in the noise condition and the ability to update information for both groups. In summary, noise generates a significantly higher PE and brings explicit processing capacity into play, irrespective of hearing. This suggest that increased PE involves other factors such as type of task that is to be performed, performance in the cognitive skill required solving the task at hand and whether noise is present. We therefore suggest that special consideration in hearing care should be made to the individual′s prerequisites on these factors in the labor market.

  7. Bone-anchored hearing aids are effective and associated with a high degree of satisfaction

    DEFF Research Database (Denmark)

    Gardell, Ida Sofie Kristina; Andresen, Kathrine; Faber, Christian Emil

    2015-01-01

    INTRODUCTION: The objective of this study was to evaluate patients' satisfaction with bone-anchored hearing aids (BAHA). METHODS: This study was retrospective and based on a postal questionnaire. The study sample consisted of patients undergoing surgery at Odense University Hospital in the 1992......-2013-period. The questionnaire was a combination of Satisfaction with Amplification in Daily Life questions from the Hearing Aid Research Lab at the University of Memphis and questions used in a previous Danish study. We also used data from each patient's medical records. All information was collected...... in a database. RESULTS: The response rate was 80% and the user percentage 88. The majority of the patients used their BAHA seven days a week and most of the day. 88% reported that it was in their best interest that they had received a BAHA. 80% of the respondents were able to communicate better using their BAHA...

  8. Sex-specific predictors of hearing-aid use in older persons: The age, gene/environment susceptibility - Reykjavik study

    Science.gov (United States)

    Fisher, Diana E.; Li, Chuan-Ming; Hoffman, Howard J.; Chiu, May S.; Themann, Christa L.; Petersen, Hannes; Jonsson, Palmi V.; Jonsson, Helgi; Jonasson, Fridbert; Sverrisdottir, Johanna Eyrun; Launer, Lenore J.; Eiriksdottir, Gudny; Gudnason, Vilmundur; Cotch, Mary Frances

    2015-01-01

    Objective We estimate the prevalence of hearing-aid use in Iceland and identify sex-specific factors associated with use. Design Population-based cohort study. Study sample A total of 5172 age, gene/environment susceptibility - Reykjavik study (AGES-RS) participants, aged 67 to 96 years (mean age 76.5 years), who completed air-conduction and pure-tone audiometry. Results Hearing-aid use was reported by 23.0% of men and 15.9% of women in the cohort, although among participants with at least moderate hearing loss in the better ear (pure-tone average [PTA] of thresholds at 0.5, 1, 2, and 4 kHz ≥ 35 dB hearing level [HL]) it was 49.9% and did not differ by sex. Self-reported hearing loss was the strongest predictor of hearing-aid use in men [OR: 2.68 (95% CI: 1.77, 4.08)] and women [OR: 3.07 (95% CI: 1.94, 4.86)], followed by hearing loss severity based on audiometry. Having diabetes or osteoarthritis were significant positive predictors of use in men, whereas greater physical activity and unimpaired cognitive status were important in women. Conclusions Hearing-aid use was comparable in Icelandic men and women with moderate or greater hearing loss. Self-recognition of hearing loss was the factor most predictive of hearing-aid use; other influential factors differed for men and women. PMID:25816699

  9. Binaural Hearing Ability With Bilateral Bone Conduction Stimulation in Subjects With Normal Hearing: Implications for Bone Conduction Hearing Aids.

    Science.gov (United States)

    Zeitooni, Mehrnaz; Mäki-Torkko, Elina; Stenfelt, Stefan

    The purpose of this study is to evaluate binaural hearing ability in adults with normal hearing when bone conduction (BC) stimulation is bilaterally applied at the bone conduction hearing aid (BCHA) implant position as well as at the audiometric position on the mastoid. The results with BC stimulation are compared with bilateral air conduction (AC) stimulation through earphones. Binaural hearing ability is investigated with tests of spatial release from masking and binaural intelligibility level difference using sentence material, binaural masking level difference with tonal chirp stimulation, and precedence effect using noise stimulus. In all tests, results with bilateral BC stimulation at the BCHA position illustrate an ability to extract binaural cues similar to BC stimulation at the mastoid position. The binaural benefit is overall greater with AC stimulation than BC stimulation at both positions. The binaural benefit for BC stimulation at the mastoid and BCHA position is approximately half in terms of decibels compared with AC stimulation in the speech based tests (spatial release from masking and binaural intelligibility level difference). For binaural masking level difference, the binaural benefit for the two BC positions with chirp signal phase inversion is approximately twice the benefit with inverted phase of the noise. The precedence effect results with BC stimulation at the mastoid and BCHA position are similar for low frequency noise stimulation but differ with high-frequency noise stimulation. The results confirm that binaural hearing processing with bilateral BC stimulation at the mastoid position is also present at the BCHA implant position. This indicates the ability for binaural hearing in patients with good cochlear function when using bilateral BCHAs.

  10. Hearing aid processing strategies for listeners with different auditory profiles: Insights from the BEAR project

    DEFF Research Database (Denmark)

    Wu, Mengfan; El-Haj-Ali, Mouhamad; Sanchez Lopez, Raul

    hearing aid settings that differed in terms of signal-to-noise ratio (SNR) improvement and temporal and spectral speech distortions were selected for testing based on a comprehensive technical evaluation of different parameterisations of the hearing aid simulator. Speech-in-noise perception was assessed...... stimulus comparison paradigm. RESULTS We hypothesize that the perceptual outcomes from the six hearing aid settings will differ across listeners with different auditory profiles. More specifically, we expect listeners showing high sensitivity to temporal and spectral differences to perform best with and....../or to favour hearing aid settings that preserve those cues. In contrast, we expect listeners showing low sensitivity to temporal and spectral differences to perform best with and/or to favour settings that maximize SNR improvement, independent of any additional speech distortions. Altogether, we anticipate...

  11. Comparisons of client and clinician views of the importance of factors in client-clinician interaction in hearing aid purchase decisions.

    Science.gov (United States)

    Poost-Foroosh, Laya; Jennings, Mary Beth; Cheesman, Margaret F

    2015-03-01

    Despite clinical recognition of the adverse effects of acquired hearing loss, only a small proportion of adults who could benefit use hearing aids. Hearing aid adoption has been studied in relationship to client-related and hearing aid technology-related factors. The influence of the client-clinician interaction in the decision to purchase hearing aids has not been explored in any depth. Importance ratings of a sample of adults having a recent hearing aid recommendation (clients) and hearing healthcare professionals (clinicians) from across Canada were compared on factors in client-clinician interactions that influence hearing aid purchase decisions. A cross-sectional approach was used to obtain online and paper-based concept ratings. Participants were 43 adults (age range, 45-85 yr) who had received a first hearing aid recommendation in the 3 mo before participation. A total of 54 audiologists and 20 hearing instrument practitioners from a variety of clinical settings who prescribed or dispensed hearing aids completed the concept-rating task. The task consisted of 122 items that had been generated via concept mapping in a previous study and which resulted in the identification of eight concepts that may influence hearing aid purchase decisions. Participants rated "the importance of each of the statements in a person's decision to purchase a hearing aid" on a 5-point Likert scale, from 1 = minimally important to 5 = extremely important. For the initial data analysis, the ratings for each of the items included in each concept were averaged for each participant to provide an estimate of the overall importance rating of each concept. Multivariate analysis of variance was used to compare the mean importance ratings of the clients to the clinicians. Ratings of individual statements were also compared in order to investigate the directionality of the importance ratings within concepts. There was a significant difference in the mean ratings for clients and clinicians for

  12. Hearing Benefit and Rated Satisfaction in Children with Unilateral Conductive Hearing Loss Using a Transcutaneous Magnetic-Coupled Bone-Conduction Hearing Aid.

    Science.gov (United States)

    Polonenko, Melissa J; Carinci, Lora; Gordon, Karen A; Papsin, Blake C; Cushing, Sharon L

    Bilateral hearing is important for learning, development, and function in complex everyday environments. Children with conductive and mixed hearing loss (HL) have been treated for years with percutaneous coupling through an abutment, which achieves powerful output, but the implant site is susceptible to skin reactions and trauma. To overcome these complications, transcutaneous magnetic coupling systems were recently introduced. The purpose of the study was to evaluate whether the new transcutaneous magnetic coupling is an effective coupling paradigm for bone-conduction hearing aids (BCHAs). We hypothesized that magnetic coupling will (1) have limited adverse events, (2) provide adequate functional gain, (3) improve spatial hearing and aid listening in everyday situations, and (4) provide satisfactory outcomes to children and their families given one normal hearing ear. Retrospective analysis of audiological outcomes in a tertiary academic pediatric hospital. Nine children aged 5-17 yr with permanent unilateral conductive HL (UCHL) or mixed HL were implanted with a transcutaneous magnet-retained BCHA. Average hearing thresholds of the better and implanted ears were 12.3 ± 11.5 dB HL and 69.1 ± 11.6 dB HL, respectively, with a 59.4 ± 4.8 dB (mean ± standard deviation) conductive component. Data were extracted from audiology charts of the children with permanent UCHL or mixed HL who qualified for a surgically retained BCHA and agreed to the magnetic coupling. Outcomes were collected from the 3- to 9-mo follow-up appointments, and included surgical complications, aided audiometric thresholds with varying magnet strength, speech performance in quiet and noise, and patient-rated benefit and satisfaction using questionnaires. Repeated measures analysis of variance was used to analyze audiometric outcomes, and nonparametric tests were used to evaluate rated benefit and satisfaction. All nine children tolerated the device and only one child had discomfort at the wound

  13. Interpolation Filter Design for Hearing-Aid Audio Class-D Output Stage Application

    DEFF Research Database (Denmark)

    Pracný, Peter; Bruun, Erik; Llimos Muntal, Pere

    2012-01-01

    This paper deals with a design of a digital interpolation filter for a 3rd order multi-bit ΣΔ modulator with over-sampling ratio OSR = 64. The interpolation filter and the ΣΔ modulator are part of the back-end of an audio signal processing system in a hearing-aid application. The aim in this paper...... is to compare this design to designs presented in other state-of-the-art works ranging from hi-fi audio to hearing-aids. By performing comparison, trends and tradeoffs in interpolation filter design are indentified and hearing-aid specifications are derived. The possibilities for hardware reduction...... in the interpolation filter are investigated. Proposed design simplifications presented here result in the least hardware demanding combination of oversampling ratio, number of stages and number of filter taps among a number of filters reported for audio applications....

  14. Technology transfer of hearing aids to low and middle income countries: policy and market factors.

    Science.gov (United States)

    Seelman, Katherine D; Werner, Roye

    2014-09-01

    The competitive market advantages of industry and the balancing force of international governmental organizations (IGOs) are examined to identify market and policy in support of sustainable technology transfer of hearing aids to low and middle income countries. A second purpose is to examine the usefulness of findings for other assistive technologies (AT). Searches of electronic databases, IGO documents, industry reports and journals were supplemented by informal discussions with industry and IGO staff and audiologists. The value chain is used to examine the competitive advantage of industry and the balancing tools of certain IGOs. Both industry and IGOs engage in intellectual property (IP) and competition activities and are active in each segment of the hearing aid value chain. Their market and policy objectives and strategies are different. IGOs serve as balancing forces for the competitive advantages of industry. The hearing aid market configuration and hearing aid fitting process are not representative of other AT products but IP, trade and competition policy tools used by IGOs and governments are relevant to other AT. The value chain is a useful tool to identify the location of price mark-ups and the influence of actors. Market factors and reimbursement and subsidization policies drive hearing aid innovation. UN-related international government organization activities are responsive to the needs of disability populations who cannot afford assistive technology. Policy tools used by international governmental organizations are applicable across assistive technology. A partnership model is important to distribution of hearing aids to low and middle income countries.

  15. The bone-anchored hearing aid

    DEFF Research Database (Denmark)

    Foghsgaard, Søren

    2014-01-01

    The bone-anchored hearing aid (Baha) was introduced in 1977 by Tjellström and colleagues and has now been used clinically for over 30 years. Generally, the outcomes are good, and several studies have shown improved audiological- and quality of life outcomes. The principle of the Baha is, that sou...... vibrations are led directly to the inner ear via the mastoid bone, bypassing the middle ear. This is achieved via an osseointegrated implant and a skin-penetrating abutment. Studies report high success rates and a majority of complications as typically minor in nature....

  16. Auditory, Visual, and Auditory-Visual Perception of Emotions by Individuals with Cochlear Implants, Hearing Aids, and Normal Hearing

    Science.gov (United States)

    Most, Tova; Aviner, Chen

    2009-01-01

    This study evaluated the benefits of cochlear implant (CI) with regard to emotion perception of participants differing in their age of implantation, in comparison to hearing aid users and adolescents with normal hearing (NH). Emotion perception was examined by having the participants identify happiness, anger, surprise, sadness, fear, and disgust.…

  17. Vocabulary Facilitates Speech Perception in Children With Hearing Aids.

    Science.gov (United States)

    Klein, Kelsey E; Walker, Elizabeth A; Kirby, Benjamin; McCreery, Ryan W

    2017-08-16

    We examined the effects of vocabulary, lexical characteristics (age of acquisition and phonotactic probability), and auditory access (aided audibility and daily hearing aid [HA] use) on speech perception skills in children with HAs. Participants included 24 children with HAs and 25 children with normal hearing (NH), ages 5-12 years. Groups were matched on age, expressive and receptive vocabulary, articulation, and nonverbal working memory. Participants repeated monosyllabic words and nonwords in noise. Stimuli varied on age of acquisition, lexical frequency, and phonotactic probability. Performance in each condition was measured by the signal-to-noise ratio at which the child could accurately repeat 50% of the stimuli. Children from both groups with larger vocabularies showed better performance than children with smaller vocabularies on nonwords and late-acquired words but not early-acquired words. Overall, children with HAs showed poorer performance than children with NH. Auditory access was not associated with speech perception for the children with HAs. Children with HAs show deficits in sensitivity to phonological structure but appear to take advantage of vocabulary skills to support speech perception in the same way as children with NH. Further investigation is needed to understand the causes of the gap that exists between the overall speech perception abilities of children with HAs and children with NH.

  18. Transitioning hearing aid users with severe and profound loss to a new gain/frequency response: benefit, perception, and acceptance.

    Science.gov (United States)

    Convery, Elizabeth; Keidser, Gitte

    2011-03-01

    Adults with severe and profound hearing loss tend to be long-term, full-time users of amplification who are highly reliant on their hearing aids. As a result of these characteristics, they are often reluctant to update their hearing aids when new features or signal-processing algorithms become available. Due to the electroacoustic constraints of older devices, many severely and profoundly hearing-impaired adults continue to wear hearing aids that provide more low- and mid-frequency gain and less high-frequency gain than would be prescribed by the National Acoustic Laboratories' revised formula with profound correction factor (NAL-RP). To investigate the effect of a gradual change in gain/frequency response on experienced hearing-aid wearers with moderately severe to profound hearing loss. Double-blind, randomized controlled trial. Twenty-three experienced adult hearing-aid users with severe and profound hearing loss participated in the study. Participants were selected for inclusion in the study if the gain/frequency response of their own hearing aids differed significantly from their NAL-RP prescription. Participants were assigned either to a control or to an experimental group balanced for aided ear three-frequency pure-tone average (PTA) and age. Participants were fitted with Siemens Artis 2 SP behind-the-ear (BTE) hearing aids that were matched to the gain/frequency response of their own hearing aids for a 65 dB SPL input level. The experimental group progressed incrementally to their NAL-RP targets over the course of 15 wk, while the control group maintained their initial settings throughout the study. Aided speech discrimination testing, loudness scaling, and structured questionnaires were completed at 3, 6, 9, 12, and 15 wk postfitting. A paired comparison between the old and new gain/frequency responses was completed at 1 and 15 wk postfitting. Statistical analysis was conducted to examine differences between the experimental and control groups and changes

  19. The effect of multimicrophone noise reduction systems on sound source localization by users of binaural hearing aids.

    Science.gov (United States)

    Van den Bogaert, Tim; Doclo, Simon; Wouters, Jan; Moonen, Marc

    2008-07-01

    This paper evaluates the influence of three multimicrophone noise reduction algorithms on the ability to localize sound sources. Two recently developed noise reduction techniques for binaural hearing aids were evaluated, namely, the binaural multichannel Wiener filter (MWF) and the binaural multichannel Wiener filter with partial noise estimate (MWF-N), together with a dual-monaural adaptive directional microphone (ADM), which is a widely used noise reduction approach in commercial hearing aids. The influence of the different algorithms on perceived sound source localization and their noise reduction performance was evaluated. It is shown that noise reduction algorithms can have a large influence on localization and that (a) the ADM only preserves localization in the forward direction over azimuths where limited or no noise reduction is obtained; (b) the MWF preserves localization of the target speech component but may distort localization of the noise component. The latter is dependent on signal-to-noise ratio and masking effects; (c) the MWF-N enables correct localization of both the speech and the noise components; (d) the statistical Wiener filter approach introduces a better combination of sound source localization and noise reduction performance than the ADM approach.

  20. Corrosion failure analysis of hearing aid battery-spring contacts

    DEFF Research Database (Denmark)

    Gudla, Visweswara Chakravarthy; Ambat, Rajan

    2017-01-01

    the susceptibility of these systems to galvanic corrosion. In this study, traditional behind the ear (BTE) hearing aid systems, which failed during service were analysed. Failure analysis was performed on the dome type battery-spring contact systems. The morphology of the contact areas was observed using scanning......Reliability of low power electrical contacts such as those in hearing aid battery-spring systems is a very critical aspect for the overall performance of the device. These systems are exposed to certain harsh environments like high humidity and elevated temperatures, and often in combination...... electron microscopy, and the compositional analysis of the corrosion products and contaminants was performed using energy dispersive X-ray spectroscopy. Wear track morphology was observed on the contact points, and the top coating on the dome was worn out exposing the substrate spring material...

  1. A multicenter study on objective and subjective benefits with a transcutaneous bone-anchored hearing aid device

    DEFF Research Database (Denmark)

    Hougaard, Dan Dupont; Boldsen, Soren Kjaergaard; Jensen, Anne Marie

    2017-01-01

    Examination of objective as well as subjective outcomes with a new transcutaneous bone-anchored hearing aid device. The study was designed as a prospective multicenter consecutive case-series study involving tertiary referral centers at two Danish University Hospitals. A total of 23 patients were...... implanted. Three were lost to follow-up. Patients had single-sided deafness, conductive or mixed hearing loss. Intervention: Rehabilitative. Aided and unaided sound field hearing was evaluated objectively using (1) pure warble tone thresholds, (2) pure-tone average (PTA4), (3) speech discrimination score...... (SDS) in quiet, and (4) speech reception threshold 50% at 70 dB SPL noise level (SRT50%). Subjective benefit was evaluated by three validated questionnaires: (1) the IOI-HA, (2) the SSQ-12, and (3) a questionnaire evaluating both the frequency and the duration of hearing aid usage. The mean aided PTA4...

  2. The Personal Hearing System—A Software Hearing Aid for a Personal Communication System

    Directory of Open Access Journals (Sweden)

    Giso Grimm

    2009-01-01

    Full Text Available A concept and architecture of a personal communication system (PCS is introduced that integrates audio communication and hearing support for the elderly and hearing-impaired through a personal hearing system (PHS. The concept envisions a central processor connected to audio headsets via a wireless body area network (WBAN. To demonstrate the concept, a prototype PCS is presented that is implemented on a netbook computer with a dedicated audio interface in combination with a mobile phone. The prototype can be used for field-testing possible applications and to reveal possibilities and limitations of the concept of integrating hearing support in consumer audio communication devices. It is shown that the prototype PCS can integrate hearing aid functionality, telephony, public announcement systems, and home entertainment. An exemplary binaural speech enhancement scheme that represents a large class of possible PHS processing schemes is shown to be compatible with the general concept. However, an analysis of hardware and software architectures shows that the implementation of a PCS on future advanced cell phone-like devices is challenging. Because of limitations in processing power, recoding of prototype implementations into fixed point arithmetic will be required and WBAN performance is still a limiting factor in terms of data rate and delay.

  3. The Personal Hearing System—A Software Hearing Aid for a Personal Communication System

    Science.gov (United States)

    Grimm, Giso; Guilmin, Gwénaël; Poppen, Frank; Vlaming, Marcel S. M. G.; Hohmann, Volker

    2009-12-01

    A concept and architecture of a personal communication system (PCS) is introduced that integrates audio communication and hearing support for the elderly and hearing-impaired through a personal hearing system (PHS). The concept envisions a central processor connected to audio headsets via a wireless body area network (WBAN). To demonstrate the concept, a prototype PCS is presented that is implemented on a netbook computer with a dedicated audio interface in combination with a mobile phone. The prototype can be used for field-testing possible applications and to reveal possibilities and limitations of the concept of integrating hearing support in consumer audio communication devices. It is shown that the prototype PCS can integrate hearing aid functionality, telephony, public announcement systems, and home entertainment. An exemplary binaural speech enhancement scheme that represents a large class of possible PHS processing schemes is shown to be compatible with the general concept. However, an analysis of hardware and software architectures shows that the implementation of a PCS on future advanced cell phone-like devices is challenging. Because of limitations in processing power, recoding of prototype implementations into fixed point arithmetic will be required and WBAN performance is still a limiting factor in terms of data rate and delay.

  4. Development and assessment of two fixed-array microphones for use with hearing aids

    NARCIS (Netherlands)

    Bilsen, F.A.; Soede, W.; Berkhout, A.J.

    1993-01-01

    Hearing-impaired listeners often have great difficulty understanding speech in situations with background noise (e.g., meetings, parties) . Conventional hearing aids offer insufficient directivity to significantly reduce background noise relative to the desired speech signal . Based on array

  5. Hearing Aids

    Science.gov (United States)

    ... primarily useful in improving the hearing and speech comprehension of people who have hearing loss that results ... and you can change the program for different listening environments—from a small, quiet room to a ...

  6. Are open-fit hearing aids a possible alternative to bone-anchored hearing devices in patients with mild to severe hearing loss? A preliminary trial

    Directory of Open Access Journals (Sweden)

    Amberley V. Ostevik

    2013-08-01

    Full Text Available Open-fit hearing aids (OFHAs may be of benefit for some individuals with chronic outer and middle ear conditions for which boneanchored hearing devices (BAHDs are normally recommended. The purpose of this study was to compare performance between OFHAs and BAHDs. A Starkey Destiny 800 OFHA was fit on eight adult BAHD users and speech perception measures in quiet and in background noise were compared under two different test conditions: i BAHD only and ii OFHA only. Equivalent outcome measure performance between these two conditions suggests that the OFHA was able to provide sufficient amplification for mild to moderate degrees of hearing loss (pure-tone averages (PTAs less than 47 dB HL. The improved speech perception performances and increased loudness ratings observed for several of the participants with moderately-severe to severe degrees of hearing loss (PTAs of 47 dB HL or greater in the BAHD only condition suggest that the OFHA did not provide sufficient amplification for these individuals. Therefore, OFHAs may be a successful alternative to the BAHD for individuals with no more than a moderate conductive hearing loss who are unable or unwilling to undergo implant surgery or unable to wear conventional hearing aids due to allergies, irritation, or chronic infection associated with the ear being blocked with a shell or earmold.

  7. Social representation of hearing aids: cross-cultural study in India, Iran, Portugal, and the United Kingdom

    Directory of Open Access Journals (Sweden)

    Manchaiah V

    2015-10-01

    Full Text Available Vinaya Manchaiah,1 Berth Danermark,2 Vinay,3 Tayebeh Ahmadi,4 David Tomé,5 Rajalakshmi Krishna,6 Per Germundsson7 1Department of Speech and Hearing Sciences, Lamar University, Beaumont, Texas, USA; 2Swedish Institute for Disability Research, Örebro University, Örebro, Sweden; 3Department of Clinical Medicine, University of Tromsø, Tromsø, Norway; 4Department of Audiology, University of Social Welfare and Rehabilitation Sciences, Tehran, Iran; 5Department of Audiology, School of Allied Health Sciences, Polytechnic Institute of Porto, Vila Nova de Gaia, Portugal; 6All India Institute of Speech and Hearing, University of Mysore, Mysore, India; 7The Department of Health and Welfare Studies, Malmö University, Malmö, Sweden Background: The current study was aimed at understanding the social representation of hearing aids in India, Iran, Portugal, and the United Kingdom. We also compared these results to explore the cross-cultural differences and similarities among these countries. Methods: The study involved a cross-sectional design, and the data were collected from four different countries using the snowball sampling method. Data were analyzed using a content analysis to identify the most-similar categories of responses reported, a co-occurrences analysis to see which of these categories are reported commonly, and a chi-square analysis to study if there was any association between positive, neutral, and negative connotations among participants in different countries. Results: The current study revealed four different social representations of hearing aids from India, Iran, Portugal, and the United Kingdom, and also a global index. Conclusion: The study results provide very useful insights into how hearing aids are represented in the society. These findings may have important implications for public education and also for manufacturers from the viewpoint of designing and marketing hearing aids in different countries. Keywords: hearing aids

  8. Relating working memory to compression parameters in clinically fit hearing AIDS.

    Science.gov (United States)

    Souza, Pamela E; Sirow, Lynn

    2014-12-01

    Several laboratory studies have demonstrated that working memory may influence response to compression speed in controlled (i.e., laboratory) comparisons of compression. In this study, the authors explored whether the same relationship would occur under less controlled conditions, as might occur in a typical audiology clinic. Participants included 27 older adults who sought hearing care in a private practice audiology clinic. Working memory was measured for each participant using a reading span test. The authors examined the relationship between working memory and aided speech recognition in noise, using clinically fit hearing aids with a range of compression speeds. Working memory, amount of hearing loss, and age each contributed to speech recognition, but the contribution depended on the speed of the compression processor. For fast-acting compression, the best performance was obtained by patients with high working memory. For slow-acting compression, speech recognition was affected by age and amount of hearing loss but was not affected by working memory. Despite the expectation of greater variability from differences in compression implementation, number of compression channels, or attendant signal processing, the relationship between working memory and compression speed showed a similar pattern as results from more controlled, laboratory-based studies.

  9. 21 CFR 801.421 - Hearing aid devices; conditions for sale.

    Science.gov (United States)

    2010-04-01

    ...) Waiver to the medical evaluation requirements. If the prospective hearing aid user is 18 years of age or..., or in the predominate method of communication used during the sale; (3) Afford the prospective user...

  10. Lithium-ion batteries for hearing aid applications. II. Pulse discharge and safety tests

    Science.gov (United States)

    Passerini, S.; Coustier, F.; Owens, B. B.

    Rechargeable lithium-ion batteries were designed to meet the power requirements of hearing aid devices (HADs). The batteries were designed in a 312-button cell size, compatible with existing hearing aids. The batteries were tested to evaluate the design and the electrochemical performance, as they relate to a typical hearing aid application. The present report covers the pulse capabilities, cycle life and preliminary safety tests. The results are compared with other battery chemistries: secondary lithium-alloy and nickel-metal hydride batteries and primary Zn-air batteries. The cell AC impedance was stable over the frequency range between 1 and 50 kHz, ranging between 5 Ω at the higher frequency and 12 Ω at the lower extreme. Pulse tests were consistent with these values, as the cells were capable of providing a series of 100 mA pulses of 10-s duration. The safety tests suggest that the design is intrinsically safe with respect to the most common types of abuse conditions.

  11. Hearing Aid-Induced Plasticity in the Auditory System of Older Adults: Evidence from Speech Perception

    Science.gov (United States)

    Lavie, Limor; Banai, Karen; Karni, Avi; Attias, Joseph

    2015-01-01

    Purpose: We tested whether using hearing aids can improve unaided performance in speech perception tasks in older adults with hearing impairment. Method: Unaided performance was evaluated in dichotic listening and speech-­in-­noise tests in 47 older adults with hearing impairment; 36 participants in 3 study groups were tested before hearing aid…

  12. Severe difficulties with word recognition in noise after platinum chemotherapy in childhood, and improvements with open-fitting hearing-aids.

    Science.gov (United States)

    Einarsson, Einar-Jón; Petersen, Hannes; Wiebe, Thomas; Fransson, Per-Anders; Magnusson, Måns; Moëll, Christian

    2011-10-01

    To investigate word recognition in noise in subjects treated in childhood with chemotherapy, study benefits of open-fitting hearing-aids for word recognition, and investigate whether self-reported hearing-handicap corresponded to subjects' word recognition ability. Subjects diagnosed with cancer and treated with platinum-based chemotherapy in childhood underwent audiometric evaluations. Fifteen subjects (eight females and seven males) fulfilled the criteria set for the study, and four of those received customized open-fitting hearing-aids. Subjects with cisplatin-induced ototoxicity had severe difficulties recognizing words in noise, and scored as low as 54% below reference scores standardized for age and degree of hearing loss. Hearing-impaired subjects' self-reported hearing-handicap correlated significantly with word recognition in a quiet environment but not in noise. Word recognition in noise improved markedly (up to 46%) with hearing-aids, and the self-reported hearing-handicap and disability score were reduced by more than 50%. This study demonstrates the importance of testing word recognition in noise in subjects treated with platinum-based chemotherapy in childhood, and to use specific custom-made questionnaires to evaluate the experienced hearing-handicap. Open-fitting hearing-aids are a good alternative for subjects suffering from poor word recognition in noise.

  13. Audiological Rehabilitation for Facilitating Hearing Aid Use: A Review.

    Science.gov (United States)

    Aazh, Hashir; Moore, Brian C J

    2017-03-01

    This article reviews and critically analyzes the design of studies on the effect of audiological rehabilitation (AR) programs on hearing aid (HA) outcomes, in order to guide future research. The design of this study was a narrative review. Studies were included in the review if they were randomized controlled trials that investigated the effects of AR on HA use and outcome between 2000 and 2016. Seven articles that met the inclusion criteria were included in the review. Most used educational rather than counseling approaches. Although educational AR programs seem to be useful in enhancing the use of communication strategies, there is limited evidence for their effect on HA use and self-perceived hearing handicap. More research is needed in this field. Future studies should (1) investigate the efficacy of AR interventions based on counseling and empathetic listening as opposed to or in addition to educational interventions, (2) use stricter criteria to include only a subpopulation of patients who do not get on well with their HAs, (3) measure the amount of HA use via data-logging and self-report questionnaires, and (4) use a matching comparison intervention for patients in the control group. American Academy of Audiology

  14. Practical considerations for a second-order directional hearing aid microphone system

    Science.gov (United States)

    Thompson, Stephen C.

    2003-04-01

    First-order directional microphone systems for hearing aids have been available for several years. Such a system uses two microphones and has a theoretical maximum free-field directivity index (DI) of 6.0 dB. A second-order microphone system using three microphones could provide a theoretical increase in free-field DI to 9.5 dB. These theoretical maximum DI values assume that the microphones have exactly matched sensitivities at all frequencies of interest. In practice, the individual microphones in the hearing aid always have slightly different sensitivities. For the small microphone separation necessary to fit in a hearing aid, these sensitivity matching errors degrade the directivity from the theoretical values, especially at low frequencies. This paper shows that, for first-order systems the directivity degradation due to sensitivity errors is relatively small. However, for second-order systems with practical microphone sensitivity matching specifications, the directivity degradation below 1 kHz is not tolerable. A hybrid order directive system is proposed that uses first-order processing at low frequencies and second-order directive processing at higher frequencies. This hybrid system is suggested as an alternative that could provide improved directivity index in the frequency regions that are important to speech intelligibility.

  15. Hearing Aid Use is Associated with Better Mini-Mental State Exam Performance.

    Science.gov (United States)

    Qian, Zhen Jason; Wattamwar, Kapil; Caruana, Francesco F; Otter, Jenna; Leskowitz, Matthew J; Siedlecki, Barbara; Spitzer, Jaclyn B; Lalwani, Anil K

    2016-09-01

    Hearing loss is associated with cognitive decline in the elderly. However, it is unknown if the use of hearing aids (HAs) is associated with enhanced cognitive function. In a cross-sectional study at an academic medical center, participants underwent audiometric evaluation, the Mini-Mental State Exam (MMSE), and the Trail Making Test, Part B (TMT-B). The impact of use versus disuse of HAs was assessed. Performance on cognitive tests was then compared with unaided hearing levels. HA users performed better on the MMSE (1.9 points; rank-sum, p = 0.008) despite having worse hearing at both high frequencies (15.3-dB hearing level; t test, p < 0.001) and low frequencies (15.7-dB hearing level; t test p < 0.001). HA use had no effect TMT-B performance. Better performance on the MMSE was correlated with both low frequency (ρ = -0.28, p = 0.021) and high frequency (ρ = -0.21, p = 0.038) hearing level, but there was no correlation between performance on the TMT-B and hearing at any frequency. Despite having poorer hearing, HA users performed better on the MMSE. Better performance on cognitive tests with auditory stimuli (MMSE) but not visual stimuli (TMT-B) suggests that hearing loss is associated with sensory-specific cognitive decline rather than global cognitive impairment. Because hearing loss is nearly universal in those older than 80 years, HAs should be strongly recommended to minimize cognitive impairment in the elderly. Copyright © 2016 American Association for Geriatric Psychiatry. Published by Elsevier Inc. All rights reserved.

  16. A customizable multi-channel loudness compensation method based on WDRC for digital hearing aids

    Science.gov (United States)

    Hu, Jiebin; Wang, Mingjiang; Ma, Min

    2017-08-01

    Loudness compensation is the most significant signal processing algorithm in digital hearing aids at present. An algorithm of multi-channel loudness compensation for embedded system has been put forward in this paper. The number of channels is customizable in this algorithm. The algorithm can set different number and different width of channels for each patient based on frequency domain wide dynamic range compression. First, according to the requirement of patient to divide the frequency domain into multiple unequal frequency bands. And then calculate the gain of each channel according to the input-output curve of sound pressure level. Finally, the time-domain impulse response of gain is computed from Mel filter banks. It is used in conjunction with speech enhancement processing in hearing aids. Simulation results show that the algorithm can effectively enhance the loudness for different frequencies.

  17. Assessing the efficacy of hearing-aid amplification using a phoneme test

    DEFF Research Database (Denmark)

    Scheidiger, Christoph; Allen, Jont B; Dau, Torsten

    2017-01-01

    Consonant-vowel (CV) perception experiments provide valuable insights into how humans process speech. Here, two CV identification experiments were conducted in a group of hearing-impaired (HI) listeners, using 14 consonants followed by the vowel /ɑ/. The CVs were presented in quiet and with added......, in combination with a well-controlled phoneme speech test, may be used to assess the impact of hearing-aid signal processing on speech intelligibility....

  18. Social representation of hearing aids: cross-cultural study in India, Iran, Portugal, and the United Kingdom

    Science.gov (United States)

    Manchaiah, Vinaya; Danermark, Berth; Vinay; Ahmadi, Tayebeh; Tomé, David; Krishna, Rajalakshmi; Germundsson, Per

    2015-01-01

    Background The current study was aimed at understanding the social representation of hearing aids in India, Iran, Portugal, and the United Kingdom. We also compared these results to explore the cross-cultural differences and similarities among these countries. Methods The study involved a cross-sectional design, and the data were collected from four different countries using the snowball sampling method. Data were analyzed using a content analysis to identify the most-similar categories of responses reported, a co-occurrences analysis to see which of these categories are reported commonly, and a chi-square analysis to study if there was any association between positive, neutral, and negative connotations among participants in different countries. Results The current study revealed four different social representations of hearing aids from India, Iran, Portugal, and the United Kingdom, and also a global index. Conclusion The study results provide very useful insights into how hearing aids are represented in the society. These findings may have important implications for public education and also for manufacturers from the viewpoint of designing and marketing hearing aids in different countries. PMID:26504376

  19. Influence of Loudness Compression on Hearing with Bone Anchored Hearing Implants

    OpenAIRE

    Kurz, Anja; Caversaccio, Marco; Kompis, Martin; Flynn, Marc

    2014-01-01

    Bone Anchored Hearing Implants (BAHI) are routinely used in patients with conductive or mixed hearing loss, e.g. if conventional air conduction hearing aids cannot be used. New sound processors and new fitting software now allow the adjustment of parameters such as loudness compression ratios or maximum power output separately. Today it is unclear, how the choice of these parameters influences aided speech understanding in BAHI users. In this prospective experimental study, the effect ...

  20. Acceptable noise level (ANL) with Danish and non-semantic speech materials in adult hearing-aid users

    DEFF Research Database (Denmark)

    Olsen, Steen Østergaard; Lantz, Johannes; Nielsen, Lars Holme

    2012-01-01

    The acceptable noise level (ANL) test is used for quantification of the amount of background noise subjects accept when listening to speech. This study investigates Danish hearing-aid users' ANL performance using Danish and non-semantic speech signals, the repeatability of ANL, and the association...... between ANL and outcome of the international outcome inventory for hearing aids (IOI-HA)....

  1. Small-Group Phonological Awareness Training for Pre-Kindergarten Children with Hearing Loss Who Wear Cochlear Implants and/or Hearing Aids

    Science.gov (United States)

    Werfel, Krystal L.; Douglas, Michael; Ackal, Leigh

    2016-01-01

    This case report details a year-long phonological awareness (PA) intervention for pre-kindergarten children with hearing loss (CHL) who use listening and spoken language. All children wore cochlear implants and/or hearing aids. Intervention occurred for 15 min/day, 4 days per week across the pre-kindergarten school year and was delivered by…

  2. Theory-of-mind development in oral deaf children with cochlear implants or conventional hearing aids.

    Science.gov (United States)

    Peterson, Candida C

    2004-09-01

    In the context of the established finding that theory-of-mind (ToM) growth is seriously delayed in late-signing deaf children, and some evidence of equivalent delays in those learning speech with conventional hearing aids, this study's novel contribution was to explore ToM development in deaf children with cochlear implants. Implants can substantially boost auditory acuity and rates of language growth. Despite the implant, there are often problems socialising with hearing peers and some language difficulties, lending special theoretical interest to the present comparative design. A total of 52 children aged 4 to 12 years took a battery of false belief tests of ToM. There were 26 oral deaf children, half with implants and half with hearing aids, evenly divided between oral-only versus sign-plus-oral schools. Comparison groups of age-matched high-functioning children with autism and younger hearing children were also included. No significant ToM differences emerged between deaf children with implants and those with hearing aids, nor between those in oral-only versus sign-plus-oral schools. Nor did the deaf children perform any better on the ToM tasks than their age peers with autism. Hearing preschoolers scored significantly higher than all other groups. For the deaf and the autistic children, as well as the preschoolers, rate of language development and verbal maturity significantly predicted variability in ToM, over and above chronological age. The finding that deaf children with cochlear implants are as delayed in ToM development as children with autism and their deaf peers with hearing aids or late sign language highlights the likely significance of peer interaction and early fluent communication with peers and family, whether in sign or in speech, in order to optimally facilitate the growth of social cognition and language.

  3. Predictors of auditory performance in hearing-aid users: The role of cognitive function and auditory lifestyle (A)

    DEFF Research Database (Denmark)

    Vestergaard, Martin David

    2006-01-01

    no objective benefit can be measured. It has been suggested that lack of agreement between various hearing-aid outcome components can be explained by individual differences in cognitive function and auditory lifestyle. We measured speech identification, self-report outcome, spectral and temporal resolution...... of hearing, cognitive skills, and auditory lifestyle in 25 new hearing-aid users. The purpose was to assess the predictive power of the nonauditory measures while looking at the relationships between measures from various auditory-performance domains. The results showed that only moderate correlation exists...... between objective and subjective hearing-aid outcome. Different self-report outcome measures showed a different amount of correlation with objective auditory performance. Cognitive skills were found to play a role in explaining speech performance and spectral and temporal abilities, and auditory lifestyle...

  4. A novel modeling method for manufacturing hearing aid using 3D medical images

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyeong Gyun [Dept of Radiological Science, Far East University, Eumseong (Korea, Republic of)

    2016-06-15

    This study aimed to suggest a novel method of modeling a hearing aid ear shell based on Digital Imaging and Communication in Medicine (DICOM) in the hearing aid ear shell manufacturing method using a 3D printer. In the experiment, a 3D external auditory meatus was extracted by using the critical values in the DICOM volume images, a nd t he modeling surface structures were compared in standard type STL (STereoLithography) files which could be recognized by a 3D printer. In this 3D modeling method, a conventional ear model was prepared, and the gaps between adjacent isograms produced by a 3D scanner were filled with 3D surface fragments to express the modeling structure. In this study, the same type of triangular surface structures were prepared by using the DICOM images. The result showed that the modeling surface structure based on the DICOM images provide the same environment that the conventional 3D printers may recognize, eventually enabling to print out the hearing aid ear shell shape.

  5. A novel modeling method for manufacturing hearing aid using 3D medical images

    International Nuclear Information System (INIS)

    Kim, Hyeong Gyun

    2016-01-01

    This study aimed to suggest a novel method of modeling a hearing aid ear shell based on Digital Imaging and Communication in Medicine (DICOM) in the hearing aid ear shell manufacturing method using a 3D printer. In the experiment, a 3D external auditory meatus was extracted by using the critical values in the DICOM volume images, a nd t he modeling surface structures were compared in standard type STL (STereoLithography) files which could be recognized by a 3D printer. In this 3D modeling method, a conventional ear model was prepared, and the gaps between adjacent isograms produced by a 3D scanner were filled with 3D surface fragments to express the modeling structure. In this study, the same type of triangular surface structures were prepared by using the DICOM images. The result showed that the modeling surface structure based on the DICOM images provide the same environment that the conventional 3D printers may recognize, eventually enabling to print out the hearing aid ear shell shape

  6. Applications of direct-to-consumer hearing devices for adults with hearing loss: a review

    Directory of Open Access Journals (Sweden)

    Manchaiah V

    2017-05-01

    outcomes of OTC devices in the elderly population. Of note, OTC outcomes appear better when a hearing health care professional supports these users.Conclusion: While some direct-to-consumer hearing devices have the capability to produce adverse effects due to production of dangerously high sound levels and internal noise, the existing literature suggests that there are potential benefits of these devices. Research of direct-to-consumer hearing devices is limited, and current published studies are of weak quality. Much effort is needed to understand the benefits and limitations of such devices on people with hearing loss. Keywords: hearing loss, presbycusis, age-related hearing loss, hearing aids, direct-to-consumer, personal sound amplification product, direct-mail hearing aids, over-the-counter hearing aids

  7. Does the acceptable noise level (ANL) predict hearing-aid use?

    DEFF Research Database (Denmark)

    Olsen, Steen Østergaard; Brännström, K Jonas

    2014-01-01

    OBJECTIVE: It has been suggested that individuals have an inherent acceptance of noise in the presence of speech, and that different acceptance of noise results in different hearing-aid (HA) use. The acceptable noise level (ANL) has been proposed for measurement of this property. It has been...... claimed that the ANL magnitude can predict hearing-aid use patterns. Many papers have been published reporting on different aspects of ANL, but none have challenged the predictive power of ANL. The purpose of this study was to discuss whether ANL can predict HA use and how more reliable ANL results can...... reviewed journals as well as a number of papers from trade journals, posters and oral presentations from audiology conventions. CONCLUSIONS: An inherent acceptance of noise in the presence of speech may exist, but no method for precise measurement of ANL is available. The ANL model for prediction of HA use...

  8. Evaluation of a clinical auditory profile in hearing-aid candidates

    DEFF Research Database (Denmark)

    Thorup, Nicoline; Santurette, Sébastien; Jørgensen, Søren

    2015-01-01

    by default. However, this does not necessary lead to the same HA benefit. This study aimed at identifying clinically relevant tests that may be informative in addition to the audiogram and relate more directly to HA benefit. Twenty-nine HI listeners performed fast tests of loudness perception, spectral...... and temporal resolution, binaural hearing, speech intelligibility in stationary and fluctuating noise, and a working-memory test. Six weeks after HA fitting they answered the International Outcome Inventory – Hearing Aid evaluation. The HI group was homogeneous based on the audiogram, but only one test...

  9. Implementation of integrated circuit and design of SAR ADC for fully implantable hearing aids.

    Science.gov (United States)

    Kim, Jong Hoon; Lee, Jyung Hyun; Cho, Jin-Ho

    2017-07-20

    The hearing impaired population has been increasing; many people suffer from hearing problems. To deal with this difficulty, various types of hearing aids are being rapidly developed. In particular, fully implantable hearing aids are being actively studied to improve the performance of existing hearing aids and to reduce the stigma of hearing loss patients. It has to be of small size and low-power consumption for easy implantation and long-term use. The objective of the study was to implement a small size and low-power consumption successive approximation register analog-to-digital converter (SAR ADC) for fully implantable hearing aids. The ADC was selected as the SAR ADC because its analog circuit components are less required by the feedback circuit of the SAR ADC than the sigma-delta ADC which is conventionally used in hearing aids, and it has advantages in the area and power consumption. So, the circuit of SAR ADC is designed considering the speech region of humans because the objective is to deliver the speech signals of humans to hearing loss patients. If the switch of sample and hold works in the on/off positions, the charge injection and clock feedthrough are produced by a parasitic capacitor. These problems affect the linearity of the hold voltage, and as a result, an error of the bit conversion is generated. In order to solve the problem, a CMOS switch that consists of NMOS and PMOS was used, and it reduces the charge injection because the charge carriers in the NMOS and PMOS have inversed polarity. So, 16 bit conversion is performed before the occurrence of the Least Significant Bit (LSB) error. In order to minimize the offset voltage and power consumption of the designed comparator, we designed a preamplifier with current mirror. Therefore, the power consumption was reduced by the power control switch used in the comparator. The layout of the designed SAR ADC was performed by Virtuoso Layout Editor (Cadence, USA). In the layout result, the size of the

  10. Low Delay Noise Reduction and Dereverberation for Hearing Aids

    Directory of Open Access Journals (Sweden)

    Heinrich W. Löllmann

    2009-01-01

    Full Text Available A new system for single-channel speech enhancement is proposed which achieves a joint suppression of late reverberant speech and background noise with a low signal delay and low computational complexity. It is based on a generalized spectral subtraction rule which depends on the variances of the late reverberant speech and background noise. The calculation of the spectral variances of the late reverberant speech requires an estimate of the reverberation time (RT which is accomplished by a maximum likelihood (ML approach. The enhancement with this blind RT estimation achieves almost the same speech quality as by using the actual RT. In comparison to commonly used post-filters in hearing aids which only perform a noise reduction, a significantly better objective and subjective speech quality is achieved. The proposed system performs time-domain filtering with coefficients adapted in the non-uniform (Bark-scaled frequency-domain. This allows to achieve a high speech quality with low signal delay which is important for speech enhancement in hearing aids or related applications such as hands-free communication systems.

  11. Feasibility of a pre-implantation fitting test for an implantable hearing aid using a VR (virtual reality) software

    International Nuclear Information System (INIS)

    Dammann, F.; Bode, A.; Heuschmid, M.; Schwaderer, E.; Schaich, M.; Seemann, M.; Claussen, C.D.; Maassen, M.; Zenner, H.P.

    2001-01-01

    Purpose: To prove the feasibility of a preoperative fitting test for an implantable hearing aid using a VR environment. Methods: A high-resolution spiral CT was performed after mastoidectomy in 10 temporal bone specimens. The bony structures were segmented and merged with the computer-aided design (CAD) data of the hearing aid in a VR environment. For each specimen a three-dimensional fitting test was carried out by three examiners determining the implantability of the hearing aid. The implantation simulation was compared with the real implantation procedure performed by an experienced ENT surgeon. Results: The used VR system enabled real-time 3D-visualisation and manipulation of CT- and CAD-data. All objects could be independently moved in all three dimensions. The VR fitting test corresponded closely with the real implantation. The implantability of the hearing aid was properly predicted by all three examiners. Conclusion: Merging CT and CAD data in a virtual reality environment bears high potential for the presurgical determination of the fit and mountability of medical implants in complex anatomical regions. (orig.) [de

  12. The Care and Use of a Child's Hearing Aid: A Practical Guide for Parents, Teachers, and Children.

    Science.gov (United States)

    Lewis, Michael A.

    The booklet is intended to provide practical information on hearing aids for hearing impaired children, their families and teachers. Illustrations are provided to describe the hearing process. The nature of hearing loss is considered in terms of types (conductive, sensori-neural, and mixed), causes, degrees, and educational implications. Four…

  13. Psychosocial health of cochlear implant users compared to that of adults with and without hearing aids: Results of a nationwide cohort study.

    Science.gov (United States)

    Bosdriesz, J R; Stam, M; Smits, C; Kramer, S E

    2018-06-01

    This study aimed to examine the psychosocial health status of adult cochlear implant (CI) users, compared to that of hearing aid (HA) users, hearing-impaired adults without hearing aids and normally hearing adults. Cross-sectional observational study, using both self-reported survey data and a speech-in-noise test. Data as collected within the Netherlands Longitudinal Study on Hearing (NL-SH) between September 2011 and June 2016 were used. Data from 1254 Dutch adults (aged 23-74), selected in a convenience sample design, were included for analyses. Psychosocial health measures included emotional and social loneliness, anxiety, depression, distress and somatisation. Psychosocial health, hearing status, use of hearing technology and covariates were measured by self-report; hearing ability was assessed through an online digit triplet speech-in-noise test. After adjusting for the degree of hearing impairment, HA users (N = 418) and hearing-impaired adults (N = 247) had significantly worse scores on emotional loneliness than CI users (N = 37). HA users had significantly higher anxiety scores than CI users in some analyses. Non-significant differences were found between normally hearing (N = 552) and CI users for all psychosocial outcomes. Psychosocial health of CI users is not worse than that of hearing-impaired adults with or without hearing aids. CI users' level of emotional loneliness is even lower than that of their hearing-impaired peers using hearing aids. A possible explanation is that CI patients receive more professional and family support, and guidance along their patient journey than adults who are fitted with hearing aids. © 2017 The Authors. Clinical Otolaryngology Published by John Wiley & Sons Ltd.

  14. Hearing aid noise suppression and working memory function

    DEFF Research Database (Denmark)

    Neher, Tobias; Wagener, Kirsten C.; Fischer, Rosa-Linde

    2018-01-01

    OBJECTIVE: Research findings concerning the relation between benefit from hearing aid (HA) noise suppression and working memory function are inconsistent. The current study thus investigated the effects of three noise suppression algorithms on auditory working memory and the relation with reading......-to-noise ratio (SNR) improvement. Auditory working memory was assessed at +6 dB SNR using listening span and N-back paradigms. STUDY SAMPLE: Twenty experienced HA users ages 55-80 with large differences in reading span. RESULTS: For the listening span measurements, there was an influence of HA setting....... CONCLUSIONS: HA noise suppression may affect the recognition and recall of speech at positive SNRs, irrespective of individual reading span. Future work should improve the reliability of the auditory working memory measurements....

  15. The Influence of Hearing Aid Use on Outcomes of Children With Mild Hearing Loss.

    Science.gov (United States)

    Walker, Elizabeth A; Holte, Lenore; McCreery, Ryan W; Spratford, Meredith; Page, Thomas; Moeller, Mary Pat

    2015-10-01

    This study examined the effects of consistent hearing aid (HA) use on outcomes in children with mild hearing loss (HL). Five- or 7-year-old children with mild HL were separated into 3 groups on the basis of patterns of daily HA use. Using analyses of variance, we compared outcomes between groups on speech and language tests and a speech perception in noise task. Regression models were used to investigate the influence of cumulative auditory experience (audibility, early intervention, HA use) on outcomes. Full-time HA users demonstrated significantly higher scores on vocabulary and grammar measures compared with nonusers. There were no significant differences between the 3 groups on articulation or speech perception measures. After controlling for the variance in age at confirmation of HL, level of audibility, and enrollment in early intervention, only amount of daily HA use was a significant predictor of grammar and vocabulary. The current results provide evidence that children's language development benefits from consistent HA use. Nonusers are at risk in areas such as vocabulary and grammar compared with other children with mild HL who wear HAs regularly. Service providers should work collaboratively to encourage consistent HA use.

  16. Applications of direct-to-consumer hearing devices for adults with hearing loss: a review

    Science.gov (United States)

    Manchaiah, Vinaya; Taylor, Brian; Dockens, Ashley L; Tran, Nicole R; Lane, Kayla; Castle, Mariana; Grover, Vibhu

    2017-01-01

    Background This systematic literature review is aimed at investigating applications of direct-to-consumer hearing devices for adults with hearing loss. This review discusses three categories of direct-to-consumer hearing devices: 1) personal sound amplification products (PSAPs), 2) direct-mail hearing aids, and 3) over-the-counter (OTC) hearing aids. Method A literature review was conducted using EBSCOhost and included the databases CINAHL, MEDLINE, and PsycINFO. After applying prior agreed inclusion and exclusion criteria, 13 reports were included in the review. Results Included studies fell into three domains: 1) electroacoustic characteristics, 2) consumer surveys, and 3) outcome evaluations. Electroacoustic characteristics of these devices vary significantly with some meeting the stringent acoustic criteria used for hearing aids, while others producing dangerous output levels (ie, over 120-dB sound pressure level). Low-end (or low-cost) devices were typically poor in acoustic quality and did not meet gain levels necessary for most adult and elderly hearing loss patterns (eg, presbycusis), especially in high frequencies. Despite direct-mail hearing aids and PSAPs being associated with lower satisfaction when compared to hearing aids purchased through hearing health care professionals, consumer surveys suggest that 5%–19% of people with hearing loss purchase hearing aids through direct-mail or online. Studies on outcome evaluation suggest positive outcomes of OTC devices in the elderly population. Of note, OTC outcomes appear better when a hearing health care professional supports these users. Conclusion While some direct-to-consumer hearing devices have the capability to produce adverse effects due to production of dangerously high sound levels and internal noise, the existing literature suggests that there are potential benefits of these devices. Research of direct-to-consumer hearing devices is limited, and current published studies are of weak quality. Much

  17. Influence of a remote microphone on localization with hearing aids

    DEFF Research Database (Denmark)

    Selby, Johan G.; Weisser, Adam; MacDonald, Ewen

    2017-01-01

    When used with hearing aids (HA), the addition of a remote microphone (RM) may alter the spatial perception of the listener. First, the RM signal is presented diotically from the HAs. Second, the processing in the HA often delays the RM signal relative to the HA microphone signals. Finally...

  18. System-Level Power Optimization for a ΣΔ D/A Converter for Hearing-Aid Application

    DEFF Research Database (Denmark)

    Pracný, Peter; Jørgensen, Ivan Harald Holger; Bruun, Erik

    2013-01-01

    This paper deals with a system-level optimization of a back-end of audio signal processing chain for hearing-aids, including a sigma-delta modulator digital-to-analog converter (DAC) and a Class D power amplifier. Compared to other stateof-the-art designs dealing with sigma-delta modulator design...... hearing-aid audio back-end system resulting in less hardware and power consumption in the interpolation filter, in the sigma-delta modulator and reduced switching rate of the Class D output stage....

  19. Temporal and spatio-temporal vibrotactile displays for voice fundamental frequency: an initial evaluation of a new vibrotactile speech perception aid with normal-hearing and hearing-impaired individuals.

    Science.gov (United States)

    Auer, E T; Bernstein, L E; Coulter, D C

    1998-10-01

    Four experiments were performed to evaluate a new wearable vibrotactile speech perception aid that extracts fundamental frequency (F0) and displays the extracted F0 as a single-channel temporal or an eight-channel spatio-temporal stimulus. Specifically, we investigated the perception of intonation (i.e., question versus statement) and emphatic stress (i.e., stress on the first, second, or third word) under Visual-Alone (VA), Visual-Tactile (VT), and Tactile-Alone (TA) conditions and compared performance using the temporal and spatio-temporal vibrotactile display. Subjects were adults with normal hearing in experiments I-III and adults with severe to profound hearing impairments in experiment IV. Both versions of the vibrotactile speech perception aid successfully conveyed intonation. Vibrotactile stress information was successfully conveyed, but vibrotactile stress information did not enhance performance in VT conditions beyond performance in VA conditions. In experiment III, which involved only intonation identification, a reliable advantage for the spatio-temporal display was obtained. Differences between subject groups were obtained for intonation identification, with more accurate VT performance by those with normal hearing. Possible effects of long-term hearing status are discussed.

  20. Clinical study on the efficacy, acceptance, and safety of hearing aids in patients with mild to moderate presbyacusis.

    Science.gov (United States)

    Romanet, Phillipe; Guy, Martine; Allaert, Francois-André

    2018-04-17

    of the study: The primary objective of this trial was to demonstrate the effect of wearing a Hearing aid (HA) on improvement of hearing and comprehension in everyday life situations. This mono-centre phase IV open-label clinical trial was carried out on men or women 40 years old or more, presenting mild or moderate first-degree presbyacusis. Presbyacusis was diagnosed by performance of pure-tone audiometry in silence. The main criterion was the comparison of the Glasgow Hearing Aid Benefit Profile (GHABP) before wearing HA and after a month of use and the secondary one was audiometric parameters. 47 patients, 60.0 ± 6.9 years old were included in the study. After 4 weeks, when wearing HA, no significant difficulty remains in the patients when they watch television (GHABP situation 1) or when they have a conversation without background noise (GHABP situation 2). To have a conversation in a busy street or a shop GHABP (situation 3) 4.4% of patients still have great difficulty, as are 2.2% of them when participating in a group conversation (GHABP situation 4). The GHABP score of residual disability for the whole of the 4 situations of difficulty is 1.3 ± 0.5, translating into no or only slight residual disability, in very significant amelioration of 1.3 ± 0.7 points (p: <0.0001), or 46.4% compared to the initial value. Audiometric parameters were also significantly improved. This study has allowed us to highlight from a clinical as well as an audiometric perspective the safety, effectiveness, as well as the important benefit of Sonalto® pre-set hearing aids on the improvement of hearing in patients presenting incipient presbyacusis.

  1. Older people's views on what they need to successfully adjust to life with a hearing aid

    OpenAIRE

    Kelly, Timothy B; Tolson, Debbie; Day, Tracy; McColgan, Gillian; Kroll, Thilo; Maclaren, William

    2013-01-01

    This article reports a study exploring what older people believe would enable them to adjust to and gain maximum benefit from wearing a hearing aid. A mixed methods approach was employed during 2006 involving interviews with key stakeholders, a survey across three Scottish health board areas and focus groups. Nine key stakeholders from six national and local organisations were interviewed about the needs of older people being fitted with hearing aids. In total, 240 older people belonging to t...

  2. An Introduction to Neural Networks for Hearing Aid Noise Recognition.

    Science.gov (United States)

    Kim, Jun W.; Tyler, Richard S.

    1995-01-01

    This article introduces the use of multilayered artificial neural networks in hearing aid noise recognition. It reviews basic principles of neural networks, and offers an example of an application in which a neural network is used to identify the presence or absence of noise in speech. The ability of neural networks to "learn" the…

  3. Should visual speech cues (speechreading) be considered when fitting hearing aids?

    Science.gov (United States)

    Grant, Ken

    2002-05-01

    When talker and listener are face-to-face, visual speech cues become an important part of the communication environment, and yet, these cues are seldom considered when designing hearing aids. Models of auditory-visual speech recognition highlight the importance of complementary versus redundant speech information for predicting auditory-visual recognition performance. Thus, for hearing aids to work optimally when visual speech cues are present, it is important to know whether the cues provided by amplification and the cues provided by speechreading complement each other. In this talk, data will be reviewed that show nonmonotonicity between auditory-alone speech recognition and auditory-visual speech recognition, suggesting that efforts designed solely to improve auditory-alone recognition may not always result in improved auditory-visual recognition. Data will also be presented showing that one of the most important speech cues for enhancing auditory-visual speech recognition performance, voicing, is often the cue that benefits least from amplification.

  4. Audiovisual spoken word recognition as a clinical criterion for sensory aids efficiency in Persian-language children with hearing loss.

    Science.gov (United States)

    Oryadi-Zanjani, Mohammad Majid; Vahab, Maryam; Bazrafkan, Mozhdeh; Haghjoo, Asghar

    2015-12-01

    The aim of this study was to examine the role of audiovisual speech recognition as a clinical criterion of cochlear implant or hearing aid efficiency in Persian-language children with severe-to-profound hearing loss. This research was administered as a cross-sectional study. The sample size was 60 Persian 5-7 year old children. The assessment tool was one of subtests of Persian version of the Test of Language Development-Primary 3. The study included two experiments: auditory-only and audiovisual presentation conditions. The test was a closed-set including 30 words which were orally presented by a speech-language pathologist. The scores of audiovisual word perception were significantly higher than auditory-only condition in the children with normal hearing (Paudiovisual presentation conditions (P>0.05). The audiovisual spoken word recognition can be applied as a clinical criterion to assess the children with severe to profound hearing loss in order to find whether cochlear implant or hearing aid has been efficient for them or not; i.e. if a child with hearing impairment who using CI or HA can obtain higher scores in audiovisual spoken word recognition than auditory-only condition, his/her auditory skills have appropriately developed due to effective CI or HA as one of the main factors of auditory habilitation. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  5. Auditory, Visual, and Auditory-Visual Speech Perception by Individuals with Cochlear Implants versus Individuals with Hearing Aids

    Science.gov (United States)

    Most, Tova; Rothem, Hilla; Luntz, Michal

    2009-01-01

    The researchers evaluated the contribution of cochlear implants (CIs) to speech perception by a sample of prelingually deaf individuals implanted after age 8 years. This group was compared with a group with profound hearing impairment (HA-P), and with a group with severe hearing impairment (HA-S), both of which used hearing aids. Words and…

  6. Hearing aid noise suppression and working memory function

    DEFF Research Database (Denmark)

    Neher, Tobias; Wagener, Kirsten C.; Fischer, Rosa-Linde

    2018-01-01

    OBJECTIVE: Research findings concerning the relation between benefit from hearing aid (HA) noise suppression and working memory function are inconsistent. The current study thus investigated the effects of three noise suppression algorithms on auditory working memory and the relation with reading......-to-noise ratio (SNR) improvement. Auditory working memory was assessed at +6 dB SNR using listening span and N-back paradigms. STUDY SAMPLE: Twenty experienced HA users ages 55-80 with large differences in reading span. RESULTS: For the listening span measurements, there was an influence of HA setting...... on sentence-final word recognition and recall, with the directional microphones leading to ~6% better performance than the single-channel noise reduction. For the N-back measurements, there was substantial test-retest variability and no influence of HA setting. No interactions with reading span were found...

  7. Hearing aid noise suppression and working memory function

    DEFF Research Database (Denmark)

    Fischer, Rosa-Linde; Neher, Tobias; Wagener, Kirsten C.

    Research findings concerning the relation between outcome from hearing aid (HA) noise suppression and working memory function are unclear. The current study thus investigated the effects of three noise suppression algorithms on auditory working memory as well as the relation with reading span......) improvement. Auditory working memory was assessed at +6 dB SNR using a listening span and an N-back paradigm. Twenty experienced HA users aged 55-80 yr with large differences in reading span took part. For the listening span measurements, there was an influence of HA setting on final word recognition...... and recall, with the directional microphone setting leading to approx. 6% better performance than the single-channel noise reduction setting. For the N-back measurements, there was substantial test-retest variability and no influence of HA setting. No interactions with reading span were found. These results...

  8. 21 CFR 801.420 - Hearing aid devices; professional and patient labeling.

    Science.gov (United States)

    2010-04-01

    ...) Maintenance and care of the hearing aid, including the procedure to follow in washing the earmold, when... with a physician, e.g., skin irritation and accelerated accumulation of cerumen (ear wax). (viii) A.... (ii) History of active drainage from the ear within the previous 90 days. (iii) History of sudden or...

  9. A conceptual framework for designing micro electrical connectors for hearing aid instruments

    DEFF Research Database (Denmark)

    Doagou Rad, Saeed; Islam, Aminul; Fuglsang-Philip, M.

    2016-01-01

    technological advancements have urged them to incorporate increased number of electrical contacts. The current paper presents a conceptual framework for designing and manufacturing novel plug and socket systems for hearing aid instruments by using the state of art manufacturing technologies for micro components...

  10. Safety and effectiveness of the Vibrant Soundbridge in treating conductive and mixed hearing loss: A systematic review.

    Science.gov (United States)

    Ernst, Arne; Todt, Ingo; Wagner, Jan

    2016-06-01

    For many years, the therapeutic approach for conductive and/or mixed hearing loss has consisted of middle ear surgery with replacement of defect ossicles, and if possible the application of a hearing aid. Advances in technology have led to the introduction of electronmagnetic active implantable devices such as the Vibrant Soundbridge (VSB). With its various coupling techniques for different pathophysiological situations in the middle ear, the VSB offers greater improvement in the hearing performance of affected persons. PubMed, OvidSP (MEDLINE), EMBASE (DIMDI), the National Institue for Health research (NIHR) Centre for Reviews and Dissemination (including the National Health Service Economic Evaluation Database, Database of Abstracts of Reviews of Effects, and Health Technology Assessment), and the Cochrane Library were searched to identify articles published between January 2006 and April 2014 that evaluated the safety and effectiveness of the VSB in comparison to no intervention, bone conduction hearing implants (BCHI), and middle ear surgery plus hearing aids for adults and children with conductive or mixed hearing loss. Study selection and data extraction was carried out by multiple reviewers. Study quality was assessed using the Oxford Centre for Evidence-Based Medicine levels of evidence (2011); and a checklist available from the Evidence Analysis Library, Academy of Nutrition and Diabetics. Thirty-six publications were identified: 19 on VSB outcomes in 294 individuals, 13 on BCHI outcomes in 666 individuals, and four on middle ear surgery plus hearing aid outcomes in 43 individuals. Two systematic reviews were also identified. Heterogeneous outcome measures made it difficult to summarize data. In general, the VSB proved to be safe and effective when compared to no intervention and BCHI, and provided more and consistent hearing gain compared to middle ear surgery plus conventional hearing aids. As demonstrated in the literature, the VSB as an active device

  11. Auditory Outcomes with Hearing Rehabilitation in Children with Unilateral Hearing Loss: A Systematic Review.

    Science.gov (United States)

    Appachi, Swathi; Specht, Jessica L; Raol, Nikhila; Lieu, Judith E C; Cohen, Michael S; Dedhia, Kavita; Anne, Samantha

    2017-10-01

    Objective Options for management of unilateral hearing loss (UHL) in children include conventional hearing aids, bone-conduction hearing devices, contralateral routing of signal (CROS) aids, and frequency-modulating (FM) systems. The objective of this study was to systematically review the current literature to characterize auditory outcomes of hearing rehabilitation options in UHL. Data Sources PubMed, EMBASE, Medline, CINAHL, and Cochrane Library were searched from inception to January 2016. Manual searches of bibliographies were also performed. Review Methods Studies analyzing auditory outcomes of hearing amplification in children with UHL were included. Outcome measures included functional and objective auditory results. Two independent reviewers evaluated each abstract and article. Results Of the 249 articles identified, 12 met inclusion criteria. Seven articles solely focused on outcomes with bone-conduction hearing devices. Outcomes favored improved pure-tone averages, speech recognition thresholds, and sound localization in implanted patients. Five studies focused on FM systems, conventional hearing aids, or CROS hearing aids. Limited data are available but suggest a trend toward improvement in speech perception with hearing aids. FM systems were shown to have the most benefit for speech recognition in noise. Studies evaluating CROS hearing aids demonstrated variable outcomes. Conclusions Data evaluating functional and objective auditory measures following hearing amplification in children with UHL are limited. Most studies do suggest improvement in speech perception, speech recognition in noise, and sound localization with a hearing rehabilitation device.

  12. Psychosocial Development in 5-Year-Old Children With Hearing Loss Using Hearing Aids or Cochlear Implants.

    Science.gov (United States)

    Wong, Cara L; Ching, Teresa Y C; Cupples, Linda; Button, Laura; Leigh, Greg; Marnane, Vivienne; Whitfield, Jessica; Gunnourie, Miriam; Martin, Louise

    2017-01-01

    This article reports on the psychosocial development and factors influencing outcomes of 5-year-old children with cochlear implants (CIs) or hearing aids (HAs). It further examines differences between children with CIs and HAs with similar levels of hearing loss. Data were collected as part of the Longitudinal Outcomes of Children with Hearing Impairment study-a prospective, population-based study. Parents/caregivers of children completed the Strengths and Difficulties Questionnaire ( n = 333), the Social Skills subscale from the Child Development Inventory ( n = 317), and questionnaires on functional auditory behavior (Parents' Evaluation of Aural/oral performance of Children), and demographics. Children completed assessments of nonverbal cognitive ability (Wechsler Non-verbal Scale of Ability) and language (Preschool Language Scale - fourth edition). On average, parent-rated Strengths and Difficulties Questionnaire scores on emotional or behavioral difficulties were within 1 SD of the normative mean; however, Child Development Inventory scores on social skills were more than 1 SD below the norm. Children with severe-to-profound hearing losses using HAs had significantly more behavioral problems than children with CIs. Regression analyses showed that non-verbal cognitive ability, language, and functional auditory behavior were significantly associated with psychosocial outcomes for children with HAs, whereas outcomes for children with CIs were associated with functional auditory behavior and the presence of additional disabilities. Age at hearing intervention, severity of hearing loss, and communication mode were not associated with outcomes. The results suggest that even children who develop good language ability with the help of a HA or CI may have psychosocial problems if they exhibit difficulties with listening and communicating in everyday environments. The findings have implications for developing interventions for young children with hearing

  13. Binaural Interference and the Effects of Age and Hearing Loss.

    Science.gov (United States)

    Mussoi, Bruna S S; Bentler, Ruth A

    2017-01-01

    The existence of binaural interference, defined here as poorer speech recognition with both ears than with the better ear alone, is well documented. Studies have suggested that its prevalence may be higher in the elderly population. However, no study to date has explored binaural interference in groups of younger and older adults in conditions that favor binaural processing (i.e., in spatially separated noise). Also, the effects of hearing loss have not been studied. To examine binaural interference through speech perception tests, in groups of younger adults with normal hearing, older adults with normal hearing for their age, and older adults with hearing loss. A cross-sectional study. Thirty-three participants with symmetric thresholds were recruited from the University of Iowa community. Participants were grouped as follows: younger with normal hearing (18-28 yr, n = 12), older with normal hearing for their age (73-87 yr, n = 9), and older with hearing loss (78-94 yr, n = 12). Prior noise exposure was ruled out. The Connected Speech Test (CST) and Hearing in Noise Test (HINT) were administered to all participants bilaterally, and to each ear separately. Test materials were presented in the sound field with speech at 0° azimuth and the noise at 180°. The Dichotic Digits Test (DDT) was administered to all participants through earphones. Hearing aids were not used during testing. Group results were compared with repeated measures and one-way analysis of variances, as appropriate. Within-subject analyses using pre-established critical differences for each test were also performed. The HINT revealed no effect of condition (individual ear versus bilateral presentation) using group analysis, although within-subject analysis showed that 27% of the participants had binaural interference (18% had binaural advantage). On the CST, there was significant binaural advantage across all groups with group data analysis, as well as for 12% of the participants at each of the two

  14. Statistically derived factors of varied importance to audiologists when making a hearing aid brand preference decision.

    Science.gov (United States)

    Johnson, Earl E; Mueller, H Gustav; Ricketts, Todd A

    2009-01-01

    To determine the amount of importance audiologists place on various items related to their selection of a preferred hearing aid brand manufacturer. Three hundred forty-three hearing aid-dispensing audiologists rated a total of 32 randomized items by survey methodology. Principle component analysis identified seven orthogonal statistical factors of importance. In rank order, these factors were Aptitude of the Brand, Image, Cost, Sales and Speed of Delivery, Exposure, Colleague Recommendations, and Contracts and Incentives. While it was hypothesized that differences among audiologists in the importance ratings of these factors would dictate their preference for a given brand, that was not our finding. Specifically, mean ratings for the six most important factors did not differ among audiologists preferring different brands. A statistically significant difference among audiologists preferring different brands was present, however, for one factor: Contracts and Incentives. Its assigned importance, though, was always lower than that for the other six factors. Although most audiologists have a preferred hearing aid brand, differences in the perceived importance of common factors attributed to brands do not largely determine preference for a particular brand.

  15. Modern prescription theory and application: realistic expectations for speech recognition with hearing AIDS.

    Science.gov (United States)

    Johnson, Earl E

    2013-01-01

    A major decision at the time of hearing aid fitting and dispensing is the amount of amplification to provide listeners (both adult and pediatric populations) for the appropriate compensation of sensorineural hearing impairment across a range of frequencies (e.g., 160-10000 Hz) and input levels (e.g., 50-75 dB sound pressure level). This article describes modern prescription theory for hearing aids within the context of a risk versus return trade-off and efficient frontier analyses. The expected return of amplification recommendations (i.e., generic prescriptions such as National Acoustic Laboratories-Non-Linear 2, NAL-NL2, and Desired Sensation Level Multiple Input/Output, DSL m[i/o]) for the Speech Intelligibility Index (SII) and high-frequency audibility were traded against a potential risk (i.e., loudness). The modeled performance of each prescription was compared one with another and with the efficient frontier of normal hearing sensitivity (i.e., a reference point for the most return with the least risk). For the pediatric population, NAL-NL2 was more efficient for SII, while DSL m[i/o] was more efficient for high-frequency audibility. For the adult population, NAL-NL2 was more efficient for SII, while the two prescriptions were similar with regard to high-frequency audibility. In terms of absolute return (i.e., not considering the risk of loudness), however, DSL m[i/o] prescribed more outright high-frequency audibility than NAL-NL2 for either aged population, particularly, as hearing loss increased. Given the principles and demonstrated accuracy of desensitization (reduced utility of audibility with increasing hearing loss) observed at the group level, additional high-frequency audibility beyond that of NAL-NL2 is not expected to make further contributions to speech intelligibility (recognition) for the average listener.

  16. Hearing Aids

    Science.gov (United States)

    ... listen to TV or your music player, play videogames, or use your phone. Talk to your audiologist ... your audiologist several times, but it's worth the benefit of being able to hear your friends and ...

  17. Quantifying the bystander-effect of 2.5G mobile telephones on the speech perception of digital hearing aid users.

    Science.gov (United States)

    Vlastarakos, P V; Nikolopoulos, T P; Manolopoulos, L; Stamou, A; Halkiotis, K K; Ferekidis, E; Georgiou, E

    2012-01-01

    To quantify the bystander-effect of 2.5G mobile telephones (2.5G-MTs) on the speech perception of digital hearing-aid (dHA) users. Differences in the susceptibility of behind-the-ear (BTE) compared to in-to-the-ear (ITE) dHAs were also assessed. Prospective-comparative study conducted at a tertiary referral centre (ENT Department) and a HA-fitting laboratory. Key-word recognition scores from open-sentence lists were calculated. Power-analysis determined that a minimum of 60 subjects with SNHL (30 in each group), using either BTE or ITE dHAs, were required for reliable study outcomes. Sixty-four adults were tested with a functioning 2.5G-MT at almost physical contact with their ear; thirty subjects used BTE and 34 ITE dHAs. Aided word recognition score differences between studied groups and within each group, while a 2.5G-MT was activated. Cut-off inclusion criterion regarding baseline aided word recognition score was 75%. Baseline aided word recognition scores for ITE dHAs were better compared to BTE ones (p ITE dHAs proved more susceptible to electromagnetic interference (p ITE HAs is not confirmed by the results of the present study. EBM level of evidence: 2c.

  18. Intention to use hearing aids: a survey based on the theory of planned behavior

    Directory of Open Access Journals (Sweden)

    Meister H

    2014-09-01

    Full Text Available Hartmut Meister,1 Linda Grugel,1 Markus Meis2 1Jean Uhrmacher Institute for Clinical ENT Research, University of Cologne, Cologne, Germany; 2Hoerzentrum Oldenburg, Oldenburg, Germany Objective: To determine the intention to use hearing aids (HAs by applying the theory of planned behavior (TPB. Design: The TPB is a widely used decision-making model based on three constructs hypothesized to influence the intention to perform a specific behavior; namely, “attitude toward the behavior”, “subjective norm”, and “behavioral control”. The survey was based on a TPB-specific questionnaire addressing factors relevant to HA provision. Study sample: Data from 204 individuals reporting hearing problems were analyzed. Different subgroups were established according to the stage of their hearing help-seeking. Results: The TPB models’ outcome depended on the subgroup. The intention of those participants who had recognized their hearing problems but had not yet consulted an ear, nose, and throat specialist was largely dominated by the “subjective norm” construct, whereas those who had already consulted an ear, nose, and throat specialist or had already tried out HAs were significantly influenced by all constructs. The intention of participants who already owned HAs was clearly less affected by the “subjective norm” construct but was largely dominated by their “attitude toward HAs”. Conclusion: The intention to use HAs can be modeled on the basis of the constructs “attitude toward the behavior”, “subjective norm”, and “behavioral control”. Individual contribution of the constructs to the model depends on the patient’s stage of hearing help-seeking. The results speak well for counseling strategies that explicitly consider the individual trajectory of hearing help-seeking. Keywords: hearing aid uptake, motivation, attitude, subjective norm, behavioral control

  19. The role of bone conduction hearing aids in congenital unilateral hearing loss: A systematic review.

    Science.gov (United States)

    Liu, C Carrie; Livingstone, Devon; Yunker, Warren K

    2017-03-01

    To systematically review the literature on the audiological and/or quality of life benefits of a bone conduction hearing aid (BCHA) in children with congenital unilateral conductive or sensorineural deafness. A systematic search was performed according to the PRISMA guidelines using the PubMed, Medline, and Embase databases. Data were collected on the following outcomes of interest: speech reception threshold, speech discrimination, sound localization, and quality of life measures. Given the heterogeneity of the data for quantitative analysis, the results are qualitatively summarized. Eight studies were included in the review. Four studies examined the audiological outcomes associated with bone conduction hearing aid implantation. There was a consistent gain in speech reception thresholds and speech discrimination, especially in noisy environments. Results pertaining to sound localization was inconsistent. The studies that examined quality of life measures reported a high usage rate of BCHAs among children. Quality of life improvements are reported with suggested benefit in the subdomain of learning. Given the potential benefits of a BCHA, along with the fact that it can be safely trialed using a headband, it is reasonable to trial a BCHA in children with congenital unilateral deafness. Should the trial offer audiological and/or quality of life benefits for the individual child, then BCHA implantation can be considered. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Use of Differential Reinforcement to Increase Hearing Aid Compliance: A Preliminary Investigation

    Science.gov (United States)

    Bass-Ringdahl, Sandie M.; Ringdahl, Joel E.; Boelter, Eric W.

    2010-01-01

    Compliance with hearing aid use can be difficult to achieve with children. This difficulty can be increased when a child presents with other disabilities, such as developmental delays. Behavioral treatments, including differential reinforcement, might be one strategy for increasing compliance by these children. In the clinical scenario discussed,…

  1. Negotiating hearing disability and hearing disabled identities

    DEFF Research Database (Denmark)

    Lykke Hindhede, Anette

    2012-01-01

        Using disability theory as a framework and social science theories of identity to strengthen the arguments, this paper explores empirically how working-age adults confront the medical diagnosis of hearing impairment. For most participants hearing impairment threatens the stability of social...... interaction and the construction of hearing disabled identities is seen as shaped in the interaction with the hearing impaired person‟s surroundings. In order to overcome the potential stigmatisation the „passing‟ as normal becomes predominant. For many the diagnosis provokes radical redefinitions of the self....... The discursively produced categorisation and subjectivity of senescence mean that rehabilitation technologies such as hearing aids identify a particular life-style (disabled) which determines their social significance. Thus wearing a hearing aid works against the contemporary attempt to create socially ideal...

  2. Hearing impairment, cognition and speech understanding: exploratory factor analyses of a comprehensive test battery for a group of hearing aid users, the n200 study.

    Science.gov (United States)

    Rönnberg, Jerker; Lunner, Thomas; Ng, Elaine Hoi Ning; Lidestam, Björn; Zekveld, Adriana Agatha; Sörqvist, Patrik; Lyxell, Björn; Träff, Ulf; Yumba, Wycliffe; Classon, Elisabet; Hällgren, Mathias; Larsby, Birgitta; Signoret, Carine; Pichora-Fuller, M Kathleen; Rudner, Mary; Danielsson, Henrik; Stenfelt, Stefan

    2016-11-01

    The aims of the current n200 study were to assess the structural relations between three classes of test variables (i.e. HEARING, COGNITION and aided speech-in-noise OUTCOMES) and to describe the theoretical implications of these relations for the Ease of Language Understanding (ELU) model. Participants were 200 hard-of-hearing hearing-aid users, with a mean age of 60.8 years. Forty-three percent were females and the mean hearing threshold in the better ear was 37.4 dB HL. LEVEL1 factor analyses extracted one factor per test and/or cognitive function based on a priori conceptualizations. The more abstract LEVEL 2 factor analyses were performed separately for the three classes of test variables. The HEARING test variables resulted in two LEVEL 2 factors, which we labelled SENSITIVITY and TEMPORAL FINE STRUCTURE; the COGNITIVE variables in one COGNITION factor only, and OUTCOMES in two factors, NO CONTEXT and CONTEXT. COGNITION predicted the NO CONTEXT factor to a stronger extent than the CONTEXT outcome factor. TEMPORAL FINE STRUCTURE and SENSITIVITY were associated with COGNITION and all three contributed significantly and independently to especially the NO CONTEXT outcome scores (R(2) = 0.40). All LEVEL 2 factors are important theoretically as well as for clinical assessment.

  3. Dual Language versus English-Only Support for Bilingual Children with Hearing Loss Who Use Cochlear Implants and Hearing Aids

    Science.gov (United States)

    Bunta, Ferenc; Douglas, Michael; Dickson, Hanna; Cantu, Amy; Wickesberg, Jennifer; Gifford, René H.

    2016-01-01

    Background: There is a critical need to understand better speech and language development in bilingual children learning two spoken languages who use cochlear implants (CIs) and hearing aids (HAs). The paucity of knowledge in this area poses a significant barrier to providing maximal communicative outcomes to a growing number of children who have…

  4. Hearing: Noise-Induced Hearing Loss

    Science.gov (United States)

    ... reduce your exposure to noise by choosing quiet leisure activities rather than noisy ones. Develop the habit ... the degree of your hearing loss, you may benefit from using a hearing aid (a device you ...

  5. Hearing impairment, cognition and speech understanding: exploratory factor analyses of a comprehensive test battery for a group of hearing aid users, the n200 study

    Science.gov (United States)

    Rönnberg, Jerker; Lunner, Thomas; Ng, Elaine Hoi Ning; Lidestam, Björn; Zekveld, Adriana Agatha; Sörqvist, Patrik; Lyxell, Björn; Träff, Ulf; Yumba, Wycliffe; Classon, Elisabet; Hällgren, Mathias; Larsby, Birgitta; Signoret, Carine; Pichora-Fuller, M. Kathleen; Rudner, Mary; Danielsson, Henrik; Stenfelt, Stefan

    2016-01-01

    Abstract Objective: The aims of the current n200 study were to assess the structural relations between three classes of test variables (i.e. HEARING, COGNITION and aided speech-in-noise OUTCOMES) and to describe the theoretical implications of these relations for the Ease of Language Understanding (ELU) model. Study sample: Participants were 200 hard-of-hearing hearing-aid users, with a mean age of 60.8 years. Forty-three percent were females and the mean hearing threshold in the better ear was 37.4 dB HL. Design: LEVEL1 factor analyses extracted one factor per test and/or cognitive function based on a priori conceptualizations. The more abstract LEVEL 2 factor analyses were performed separately for the three classes of test variables. Results: The HEARING test variables resulted in two LEVEL 2 factors, which we labelled SENSITIVITY and TEMPORAL FINE STRUCTURE; the COGNITIVE variables in one COGNITION factor only, and OUTCOMES in two factors, NO CONTEXT and CONTEXT. COGNITION predicted the NO CONTEXT factor to a stronger extent than the CONTEXT outcome factor. TEMPORAL FINE STRUCTURE and SENSITIVITY were associated with COGNITION and all three contributed significantly and independently to especially the NO CONTEXT outcome scores (R2 = 0.40). Conclusions: All LEVEL 2 factors are important theoretically as well as for clinical assessment. PMID:27589015

  6. Evaluation of Extended-Wear Hearing Technology for Children with Hearing Loss.

    Science.gov (United States)

    Wolfe, Jace; Schafer, Erin; Martella, Natalie; Morais, Mila; Mann, Misty

    2015-01-01

    Research shows that many older children and teenagers who have mild to moderately severe sensorineural hearing loss do not use their hearing instruments during all waking hours. A variety of reasons may contribute toward this problem, including concerns about cosmetics associated with hearing aid use and the inconvenience of daily maintenance associated with hearing instruments. Extended-wear hearing instruments are inserted into the wearer's ear canal by an audiologist and are essentially invisible to outside observers. The goal of this study was to evaluate the potential benefits and limitations associated with use of extended-wear hearing instruments in a group of children with hearing loss. A two-way repeated measures design was used to examine performance differences obtained with the participants' daily-wear hearing instruments versus that obtained with extended-wear hearing instruments. Sixteen children, ages 10-17 yr old, with sensorineural hearing loss ranging from mild to moderately severe. Probe microphone measures were completed to evaluate the aided output of device. Behavioral test measures included word recognition in quiet, sentence recognition in noise, aided warble-tone thresholds, and psychophysical loudness scaling. Questionnaires were also administered to evaluate subjective performance with each hearing technology. Data logging suggested that many participants were not using their daily-wear hearing instruments during all waking hours (mean use was less than 6 h/day). Real ear probe microphone measurements indicated that a closer fit to the Desired Sensation Level Version 5 prescriptive targets was achieved with the children's daily-wear instruments when compared to the extended-wear instruments. There was no statistically significant difference in monosyllabic word recognition at 50 or 60 dBA obtained with the two hearing technologies. Sentence recognition in noise obtained with use of the extended-wear devices was, however, significantly

  7. Working memory and hearing aid processing: Literature findings, future directions, and clinical applications

    Directory of Open Access Journals (Sweden)

    Pamela eSouza

    2015-12-01

    Full Text Available Working memory—the ability to process and store information—has been identified as an important aspect of speech perception in difficult listening environments. Working memory can be envisioned as a limited-capacity system which is engaged when an input signal cannot be readily matched to a stored representation or template. This mismatch is expected to occur more frequently when the signal is degraded. Because working memory capacity varies among individuals, those with smaller capacity are expected to demonstrate poorer speech understanding when speech is degraded, such as in background noise. However, it is less clear whether (and how working memory should influence practical decisions, such as hearing treatment. Here, we consider the relationship between working memory capacity and response to specific hearing aid processing strategies. Three types of signal processing are considered, each of which will alter the acoustic signal: fast-acting wide-dynamic range compression, which smooths the amplitude envelope of the input signal; digital noise reduction, which may inadvertently remove speech signal components as it suppresses noise; and frequency compression, which alters the relationship between spectral peaks. For fast-acting wide-dynamic range compression, a growing body of data suggests that individuals with smaller working memory capacity may be more susceptible to such signal alterations, and may receive greater amplification benefit with low alteration processing. While the evidence for a relationship between wide-dynamic range compression and working memory appears robust, the effects of working memory on perceptual response to other forms of hearing aid signal processing are less clear cut. We conclude our review with a discussion of the opportunities (and challenges in translating information on individual working memory into clinical treatment, including clinically-feasible measures of working memory.

  8. Working Memory and Hearing Aid Processing: Literature Findings, Future Directions, and Clinical Applications.

    Science.gov (United States)

    Souza, Pamela; Arehart, Kathryn; Neher, Tobias

    2015-01-01

    Working memory-the ability to process and store information-has been identified as an important aspect of speech perception in difficult listening environments. Working memory can be envisioned as a limited-capacity system which is engaged when an input signal cannot be readily matched to a stored representation or template. This "mismatch" is expected to occur more frequently when the signal is degraded. Because working memory capacity varies among individuals, those with smaller capacity are expected to demonstrate poorer speech understanding when speech is degraded, such as in background noise. However, it is less clear whether (and how) working memory should influence practical decisions, such as hearing treatment. Here, we consider the relationship between working memory capacity and response to specific hearing aid processing strategies. Three types of signal processing are considered, each of which will alter the acoustic signal: fast-acting wide-dynamic range compression, which smooths the amplitude envelope of the input signal; digital noise reduction, which may inadvertently remove speech signal components as it suppresses noise; and frequency compression, which alters the relationship between spectral peaks. For fast-acting wide-dynamic range compression, a growing body of data suggests that individuals with smaller working memory capacity may be more susceptible to such signal alterations, and may receive greater amplification benefit with "low alteration" processing. While the evidence for a relationship between wide-dynamic range compression and working memory appears robust, the effects of working memory on perceptual response to other forms of hearing aid signal processing are less clear cut. We conclude our review with a discussion of the opportunities (and challenges) in translating information on individual working memory into clinical treatment, including clinically feasible measures of working memory.

  9. Auditory and Non-Auditory Contributions for Unaided Speech Recognition in Noise as a Function of Hearing Aid Use.

    Science.gov (United States)

    Gieseler, Anja; Tahden, Maike A S; Thiel, Christiane M; Wagener, Kirsten C; Meis, Markus; Colonius, Hans

    2017-01-01

    Differences in understanding speech in noise among hearing-impaired individuals cannot be explained entirely by hearing thresholds alone, suggesting the contribution of other factors beyond standard auditory ones as derived from the audiogram. This paper reports two analyses addressing individual differences in the explanation of unaided speech-in-noise performance among n = 438 elderly hearing-impaired listeners ( mean = 71.1 ± 5.8 years). The main analysis was designed to identify clinically relevant auditory and non-auditory measures for speech-in-noise prediction using auditory (audiogram, categorical loudness scaling) and cognitive tests (verbal-intelligence test, screening test of dementia), as well as questionnaires assessing various self-reported measures (health status, socio-economic status, and subjective hearing problems). Using stepwise linear regression analysis, 62% of the variance in unaided speech-in-noise performance was explained, with measures Pure-tone average (PTA), Age , and Verbal intelligence emerging as the three most important predictors. In the complementary analysis, those individuals with the same hearing loss profile were separated into hearing aid users (HAU) and non-users (NU), and were then compared regarding potential differences in the test measures and in explaining unaided speech-in-noise recognition. The groupwise comparisons revealed significant differences in auditory measures and self-reported subjective hearing problems, while no differences in the cognitive domain were found. Furthermore, groupwise regression analyses revealed that Verbal intelligence had a predictive value in both groups, whereas Age and PTA only emerged significant in the group of hearing aid NU.

  10. Describing the trajectory of language development in the presence of severe-to-profound hearing loss: a closer look at children with cochlear implants versus hearing aids.

    Science.gov (United States)

    Yoshinaga-Itano, Christine; Baca, Rosalinda L; Sedey, Allison L

    2010-10-01

    The objective of this investigation was to describe the language growth of children with severe or profound hearing loss with cochlear implants versus those children with the same degree of hearing loss using hearing aids. A prospective longitudinal observation and analysis. University of Colorado Department of Speech Language and Hearing Sciences. There were 87 children with severe-to-profound hearing loss from 48 to 87 months of age. All children received early intervention services through the Colorado Home Intervention Program. Most children received intervention services from a certified auditory-verbal therapist or an auditory-oral therapist and weekly sign language instruction from an instructor who was deaf or hard of hearing and native or fluent in American Sign Language. The Test of Auditory Comprehension of Language, 3rd Edition, and the Expressive One Word Picture Vocabulary Test, 3rd Edition, were the assessment tools for children 4 to 7 years of age. The expressive language subscale of the Minnesota Child Development was used in the infant/toddler period (birth to 36 mo). Average language estimates at 84 months of age were nearly identical to the normative sample for receptive language and 7 months delayed for expressive vocabulary. Children demonstrated a mean rate of growth from 4 years through 7 years on these 2 assessments that was equivalent to their normal-hearing peers. As a group, children with hearing aids deviated more from the age equivalent trajectory on the Test of Auditory Comprehension of Language, 3rd Edition, and the Expressive One Word Picture Vocabulary Test, 3rd Edition, than children with cochlear implants. When a subset of children were divided into performance categories, we found that children with cochlear implants were more likely to be "gap closers" and less likely to be "gap openers," whereas the reverse was true for the children with hearing aids for both measures. Children who are educated through oral-aural combined with

  11. Time-Varying Distortions of Binaural Information by Bilateral Hearing Aids

    Science.gov (United States)

    Rodriguez, Francisco A.; Portnuff, Cory D. F.; Goupell, Matthew J.; Tollin, Daniel J.

    2016-01-01

    In patients with bilateral hearing loss, the use of two hearing aids (HAs) offers the potential to restore the benefits of binaural hearing, including sound source localization and segregation. However, existing evidence suggests that bilateral HA users’ access to binaural information, namely interaural time and level differences (ITDs and ILDs), can be compromised by device processing. Our objective was to characterize the nature and magnitude of binaural distortions caused by modern digital behind-the-ear HAs using a variety of stimuli and HA program settings. Of particular interest was a common frequency-lowering algorithm known as nonlinear frequency compression, which has not previously been assessed for its effects on binaural information. A binaural beamforming algorithm was also assessed. Wide dynamic range compression was enabled in all programs. HAs were placed on a binaural manikin, and stimuli were presented from an arc of loudspeakers inside an anechoic chamber. Stimuli were broadband noise bursts, 10-Hz sinusoidally amplitude-modulated noise bursts, or consonant–vowel–consonant speech tokens. Binaural information was analyzed in terms of ITDs, ILDs, and interaural coherence, both for whole stimuli and in a time-varying sense (i.e., within a running temporal window) across four different frequency bands (1, 2, 4, and 6 kHz). Key findings were: (a) Nonlinear frequency compression caused distortions of high-frequency envelope ITDs and significantly reduced interaural coherence. (b) For modulated stimuli, all programs caused time-varying distortion of ILDs. (c) HAs altered the relationship between ITDs and ILDs, introducing large ITD–ILD conflicts in some cases. Potential perceptual consequences of measured distortions are discussed. PMID:27698258

  12. Speech and Hearing Problems among Older People.

    Science.gov (United States)

    Carstenson, Blue

    1978-01-01

    Findings from speech and hearing tests of older people in South Dakota community senior programs indicate the need for better testing and therapy procedures. Lipreading may be more effective than hearing aids, and factors other than hearing may be involved. Some problems and needs are noted. (MF)

  13. Horizontal sound localization in cochlear implant users with a contralateral hearing aid.

    Science.gov (United States)

    Veugen, Lidwien C E; Hendrikse, Maartje M E; van Wanrooij, Marc M; Agterberg, Martijn J H; Chalupper, Josef; Mens, Lucas H M; Snik, Ad F M; John van Opstal, A

    2016-06-01

    Interaural differences in sound arrival time (ITD) and in level (ILD) enable us to localize sounds in the horizontal plane, and can support source segregation and speech understanding in noisy environments. It is uncertain whether these cues are also available to hearing-impaired listeners who are bimodally fitted, i.e. with a cochlear implant (CI) and a contralateral hearing aid (HA). Here, we assessed sound localization behavior of fourteen bimodal listeners, all using the same Phonak HA and an Advanced Bionics CI processor, matched with respect to loudness growth. We aimed to determine the availability and contribution of binaural (ILDs, temporal fine structure and envelope ITDs) and monaural (loudness, spectral) cues to horizontal sound localization in bimodal listeners, by systematically varying the frequency band, level and envelope of the stimuli. The sound bandwidth had a strong effect on the localization bias of bimodal listeners, although localization performance was typically poor for all conditions. Responses could be systematically changed by adjusting the frequency range of the stimulus, or by simply switching the HA and CI on and off. Localization responses were largely biased to one side, typically the CI side for broadband and high-pass filtered sounds, and occasionally to the HA side for low-pass filtered sounds. HA-aided thresholds better than 45 dB HL in the frequency range of the stimulus appeared to be a prerequisite, but not a guarantee, for the ability to indicate sound source direction. We argue that bimodal sound localization is likely based on ILD cues, even at frequencies below 1500 Hz for which the natural ILDs are small. These cues are typically perturbed in bimodal listeners, leading to a biased localization percept of sounds. The high accuracy of some listeners could result from a combination of sufficient spectral overlap and loudness balance in bimodal hearing. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. System-Level Optimization of a DAC for Hearing-Aid Audio Class D Output Stage

    DEFF Research Database (Denmark)

    Pracný, Peter; Jørgensen, Ivan Harald Holger; Bruun, Erik

    2013-01-01

    This paper deals with system-level optimization of a digital-to-analog converter (DAC) for hearing-aid audio Class D output stage. We discuss the ΣΔ modulator system-level design parameters – the order, the oversampling ratio (OSR) and the number of bits in the quantizer. We show that combining...... by comparing two ΣΔ modulator designs. The proposed optimization has impact on the whole hearing-aid audio back-end system including less hardware in the interpolation filter and half the switching rate in the digital-pulse-width-modulation (DPWM) block and Class D output stage...... a reduction of the OSR with an increase of the order results in considerable power savings while the audio quality is kept. For further savings in the ΣΔ modulator, overdesign and subsequent coarse coefficient quantization are used. A figure of merit (FOM) is introduced to confirm this optimization approach...

  15. Quality investigation of miniaturized Moulded Interconnect Devices (MIDs) for hearing aid applications

    DEFF Research Database (Denmark)

    Islam, Aminul; Hansen, Hans Nørgaard; Giannekas, Nikolaos

    2015-01-01

    of positioning accuracies, dimensional fidelity and surface topography of the metal tracks. The paper proposes a novel method for the corrosion protection of the MID metal surface. The results obtained from the tests demonstrate the feasibility of the use of MIDs in the hearing aid application and an efficient...... protection of the MIDs from corrosion induced by harsh application environment....

  16. Assessment of broadband SNR estimation for hearing aid applications

    DEFF Research Database (Denmark)

    May, Tobias; Kowalewski, Borys; Fereczkowski, Michal

    2017-01-01

    was systematically investigated. The most accurate approach utilized an estimation of the clean speech power spectral density (PSD) and the noisy speech power across a sliding window of 1280 ms and achieved an total SNR estimation error below 3 dB across a wide variety of background noises and input SNRs......An accurate estimation of the broadband input signal-to-noise ratio (SNR) is a prerequisite for many hearing-aid algorithms. An extensive comparison of three SNR estimation algorithms was performed. Moreover, the influence of the duration of the analysis window on the SNR estimation performance...

  17. Directional hearing aid using hybrid adaptive beamformer (HAB) and binaural ITE array

    Science.gov (United States)

    Shaw, Scott T.; Larow, Andy J.; Gibian, Gary L.; Sherlock, Laguinn P.; Schulein, Robert

    2002-05-01

    A directional hearing aid algorithm called the Hybrid Adaptive Beamformer (HAB), developed for NIH/NIA, can be applied to many different microphone array configurations. In this project the HAB algorithm was applied to a new array employing in-the-ear microphones at each ear (HAB-ITE), to see if previous HAB performance could be achieved with a more cosmetically acceptable package. With diotic output, the average benefit in threshold SNR was 10.9 dB for three HoH and 11.7 dB for five normal-hearing subjects. These results are slightly better than previous results of equivalent tests with a 3-in. array. With an innovative binaural fitting, a small benefit beyond that provided by diotic adaptive beamforming was observed: 12.5 dB for HoH and 13.3 dB for normal-hearing subjects, a 1.6 dB improvement over the diotic presentation. Subjectively, the binaural fitting preserved binaural hearing abilities, giving the user a sense of space, and providing left-right localization. Thus the goal of creating an adaptive beamformer that simultaneously provides excellent noise reduction and binaural hearing was achieved. Further work remains before the HAB-ITE can be incorporated into a real product, optimizing binaural adaptive beamforming, and integrating the concept with other technologies to produce a viable product prototype. [Work supported by NIH/NIDCD.

  18. Cognitive Processing Speed, Working Memory, and the Intelligibility of Hearing Aid-Processed Speech in Persons with Hearing Impairment

    Directory of Open Access Journals (Sweden)

    Wycliffe Kabaywe Yumba

    2017-08-01

    Full Text Available Previous studies have demonstrated that successful listening with advanced signal processing in digital hearing aids is associated with individual cognitive capacity, particularly working memory capacity (WMC. This study aimed to examine the relationship between cognitive abilities (cognitive processing speed and WMC and individual listeners’ responses to digital signal processing settings in adverse listening conditions. A total of 194 native Swedish speakers (83 women and 111 men, aged 33–80 years (mean = 60.75 years, SD = 8.89, with bilateral, symmetrical mild to moderate sensorineural hearing loss who had completed a lexical decision speed test (measuring cognitive processing speed and semantic word-pair span test (SWPST, capturing WMC participated in this study. The Hagerman test (capturing speech recognition in noise was conducted using an experimental hearing aid with three digital signal processing settings: (1 linear amplification without noise reduction (NoP, (2 linear amplification with noise reduction (NR, and (3 non-linear amplification without NR (“fast-acting compression”. The results showed that cognitive processing speed was a better predictor of speech intelligibility in noise, regardless of the types of signal processing algorithms used. That is, there was a stronger association between cognitive processing speed and NR outcomes and fast-acting compression outcomes (in steady state noise. We observed a weaker relationship between working memory and NR, but WMC did not relate to fast-acting compression. WMC was a relatively weaker predictor of speech intelligibility in noise. These findings might have been different if the participants had been provided with training and or allowed to acclimatize to binary masking noise reduction or fast-acting compression.

  19. The Efficacy of Short-term Gated Audiovisual Speech Training for Improving Auditory Sentence Identification in Noise in Elderly Hearing Aid Users

    Science.gov (United States)

    Moradi, Shahram; Wahlin, Anna; Hällgren, Mathias; Rönnberg, Jerker; Lidestam, Björn

    2017-01-01

    This study aimed to examine the efficacy and maintenance of short-term (one-session) gated audiovisual speech training for improving auditory sentence identification in noise in experienced elderly hearing-aid users. Twenty-five hearing aid users (16 men and 9 women), with an average age of 70.8 years, were randomly divided into an experimental (audiovisual training, n = 14) and a control (auditory training, n = 11) group. Participants underwent gated speech identification tasks comprising Swedish consonants and words presented at 65 dB sound pressure level with a 0 dB signal-to-noise ratio (steady-state broadband noise), in audiovisual or auditory-only training conditions. The Hearing-in-Noise Test was employed to measure participants’ auditory sentence identification in noise before the training (pre-test), promptly after training (post-test), and 1 month after training (one-month follow-up). The results showed that audiovisual training improved auditory sentence identification in noise promptly after the training (post-test vs. pre-test scores); furthermore, this improvement was maintained 1 month after the training (one-month follow-up vs. pre-test scores). Such improvement was not observed in the control group, neither promptly after the training nor at the one-month follow-up. However, no significant between-groups difference nor an interaction between groups and session was observed. Conclusion: Audiovisual training may be considered in aural rehabilitation of hearing aid users to improve listening capabilities in noisy conditions. However, the lack of a significant between-groups effect (audiovisual vs. auditory) or an interaction between group and session calls for further research. PMID:28348542

  20. The Co-Evolution between Product Form Design and Product CategoriesThe Renaissance of the Behind-the-ear Hearing Aid

    DEFF Research Database (Denmark)

    Krabbe, Anders Dahl

    in the hearing aid industry in the period 2003-2010. Data for the study include interviews, archival material, industry statistics, and hearing care trade journals. The study contributes to theory with the following results: Co-evolutionary dynamics found in the case of technological designs were also observed...

  1. Effects of dynamic range compression on spatial selective auditory attention in normal-hearing listeners.

    Science.gov (United States)

    Schwartz, Andrew H; Shinn-Cunningham, Barbara G

    2013-04-01

    Many hearing aids introduce compressive gain to accommodate the reduced dynamic range that often accompanies hearing loss. However, natural sounds produce complicated temporal dynamics in hearing aid compression, as gain is driven by whichever source dominates at a given moment. Moreover, independent compression at the two ears can introduce fluctuations in interaural level differences (ILDs) important for spatial perception. While independent compression can interfere with spatial perception of sound, it does not always interfere with localization accuracy or speech identification. Here, normal-hearing listeners reported a target message played simultaneously with two spatially separated masker messages. We measured the amount of spatial separation required between the target and maskers for subjects to perform at threshold in this task. Fast, syllabic compression that was independent at the two ears increased the required spatial separation, but linking the compressors to provide identical gain to both ears (preserving ILDs) restored much of the deficit caused by fast, independent compression. Effects were less clear for slower compression. Percent-correct performance was lower with independent compression, but only for small spatial separations. These results may help explain differences in previous reports of the effect of compression on spatial perception of sound.

  2. Addressing Intersections in HIV/AIDS and Mental Health: The Role of Organizations for d/Deaf and Hard of Hearing Individuals in South Africa

    Science.gov (United States)

    Mall, Sumaya; Swartz, Leslie

    2011-01-01

    Like South Africans generally, d/Deaf and hard of hearing South Africans are at risk of HIV/AIDS and mental disorders resulting from barriers to communication and care. In interviews and a focus group, members of South African organizations for d/Deaf and hard of hearing individuals all gave priority to HIV/AIDS education and prevention, citing…

  3. A practical tablet-based hearing aid configuration as an exemplar project for students of instrumentation

    Directory of Open Access Journals (Sweden)

    Ricardo Simeoni

    2015-06-01

    Full Text Available This paper presents the configuration and digital signal processing details of a tablet-based hearing aid transmitting wirelessly to standard earphones, whereby the tablet performs full sound processing rather than solely providing a means of setting adjustment by streaming to conventional digital hearing aids. The presented device confirms the recognized advantages of this tablet-based approach (e.g., in relation to cost, frequency domain processing, amplification range, versatility of functionality, component battery rechargeability, and flags the future wider-spread availability of such hearing solutions within mainstream healthcare. The use of a relatively high sampling frequency was found to be beneficial for device performance, while the use of optional off-the-shelf add-on components (e.g., data acquisition device, high fidelity microphone, compact wireless transmitter/ receiver, wired headphones are also discussed in relation to performance optimization. The easy-to-follow configuration utilized is well suited to student learning/research instrumentation projects within the health and biomedical sciences. In this latter regard, the presented device was pedagogically integrated into a flipped classroom approach for the teaching of bioinstrumentation within an Allied Health Sciences School, with the subsequent establishment of positive student engagement outcomes.

  4. A Practical Tablet-Based Hearing Aid Configuration as an Exemplar Project for Students of Instrumentation.

    Science.gov (United States)

    Simeoni, Ricardo

    2015-06-11

    This paper presents the configuration and digital signal processing details of a tablet-based hearing aid transmitting wirelessly to standard earphones, whereby the tablet performs full sound processing rather than solely providing a means of setting adjustment by streaming to conventional digital hearing aids. The presented device confirms the recognized advantages of this tablet-based approach (e.g., in relation to cost, frequency domain processing, amplification range, versatility of functionality, component battery rechargeability), and flags the future wider-spread availability of such hearing solutions within mainstream healthcare. The use of a relatively high sampling frequency was found to be beneficial for device performance, while the use of optional off-the-shelf add-on components (e.g., data acquisition device, high fidelity microphone, compact wireless transmitter/receiver, wired headphones) are also discussed in relation to performance optimization. The easy-to-follow configuration utilized is well suited to student learning/research instrumentation projects within the health and biomedical sciences. In this latter regard, the presented device was pedagogically integrated into a flipped classroom approach for the teaching of bioinstrumentation within an Allied Health Sciences School, with the subsequent establishment of positive student engagement outcomes.

  5. A conceptual framework for designing micro electrical connectors for hearing aid instruments

    OpenAIRE

    Doagou Rad, Saeed; Islam, Aminul; Fuglsang-Philip, M.

    2016-01-01

    Electrical connectors play vital roles in modern electronic instruments. Hearing aid devices as advanced combinations of micro mechanics and electronics comprise various electrical connectors for different purposes. However, the current trend in the miniaturization along with the sharp technological advancements have urged them to incorporate increased number of electrical contacts. The current paper presents a conceptual framework for designing and manufacturing novel plug and socket systems...

  6. A model of mechanical contacts in hearing aids for uncertainty analysis

    DEFF Research Database (Denmark)

    Creixell Mediante, Ester; Brunskog, Jonas; Jensen, Jakob Søndergaard

    2015-01-01

    Modelling the contact between assembled parts is a key point in the design of complex structures. Uncertainties at the joint parameters arise as a result of randomness in physical properties such as contact surface, load distribution or geometric details. This is a challenge of concern in the hea......Modelling the contact between assembled parts is a key point in the design of complex structures. Uncertainties at the joint parameters arise as a result of randomness in physical properties such as contact surface, load distribution or geometric details. This is a challenge of concern...... in the hearing aid field, where the small lightweight structures present vibration modes at frequencies within the hearing range. To approach this issue, a model of contacts based on lumped elements is suggested. The joint parameters are the stiffness of a series of spring elements placed along the contact...

  7. 75 FR 54546 - Amendment of the Commission's Rules Governing Hearing Aid-Compatible Mobile Handsets

    Science.gov (United States)

    2010-09-08

    ... compatibility standards are already being met for handsets that operate on a variety of 2G and 3G air interfaces... the Commission's Rules Governing Hearing Aid- Compatible Mobile Handsets AGENCY: Federal... to extend the scope of the rules beyond the current category of Commercial Mobile Radio Service (CMRS...

  8. Hearing Aid Use and Mild Hearing Impairment: Learnings from Big Data.

    Science.gov (United States)

    Timmer, Barbra H B; Hickson, Louise; Launer, Stefan

    2017-09-01

    Previous research, mostly reliant on self-reports, has indicated that hearing aid (HA) use is related to the degree of hearing impairment (HI). No large-scale investigation of the relationship between data-logged HA use and HI has been conducted to date. This study aimed to investigate if objective measures of overall daily HA use and HA use in various listening environments are different for adults with mild HI compared to adults with moderate HI. This retrospective study used data extracted from a database of fitting appointments from an international group of HA providers. Only data from the participants' most recent fitting appointment were included in the final dataset. A total of 8,489 bilateral HA fittings of adults over the age of 18 yr, conducted between January 2013 and June 2014, were included. Participants were subsequently allocated to HI groups, based on British Society of Audiology and American Speech-Language-Hearing Association audiometric descriptors. Fitting data from participating HA providers were regularly transferred to a central server. The data, with all personal information except age and gender removed, contained participants' four-frequency average (at 500, 1000, 2000, and 4000 Hz) as well as information on HA characteristics and usage. Following data cleaning, bivariate and post hoc statistical analyses were conducted. The total sample of adults' average daily HA use was 8.52 hr (interquartile range [IQR] = 5.49-11.77) in the left ear and 8.51 hr (IQR = 5.49-11.72) in the right ear. With a few exceptions, there were no statistical differences between hours of HA use for participants with mild HI compared to those with moderate impairment. Across all mild and moderate HI groups, the most common overall HA usage was between 8 and 12 hr per day. Other factors such as age, gender, and HA style also showed no relationship to hours of use. HAs were used, on average, for 7 hr (IQR = 4.27-9.96) per day in quiet and 1 hr (IQR = 0.33-1.41) per

  9. [Rehabilitative measures in hearing-impaired children].

    Science.gov (United States)

    von Wedel, H; von Wedel, U C; Zorowka, P

    1991-12-01

    On the basis of certain fundamental data on the maturation processes of the central auditory pathways in early childhood the importance of early intervention with hearing aids is discussed and emphasized. Pathological hearing, that is acoustical deprivation in early childhood will influence the maturation process. Very often speech development is delayed if diagnosis and therapy or rehabilitation are not early enough. Anamnesis, early diagnosis and clinical differential diagnosis are required before a hearing aid can be fitted. Selection criteria and adjustment parameters are discussed, showing that the hearing aid fitting procedure must be embedded in a complex matrix of requirements related to the development of speech as well as to the cognitive, emotional and social development of the child. As a rule, finding and preparing the "best" hearing aids (binaural fitting is obligatory) for a child is a long and often difficult process, which can only be performed by specialists who are pedo-audiologists. After the binaural fitting of hearing aids an intensive hearing and speech education in close cooperation between parents, pedo-audiologist and teacher must support the whole development of the child.

  10. Effect of the STereoLithography file structure on the ear shell production for hearing aids according to DICOM images

    Energy Technology Data Exchange (ETDEWEB)

    KIm, Hyeong Gyun [Dept. of Radiological Science, Far East University, Eumseong (Korea, Republic of)

    2017-03-15

    A technique for producing the ear shell for a hearing aid using DICOM (Digital Imaging and Communication in Medicine) image and a 3D printing was studied. It is a new application method, and is an application technique that can improve the safety and infection of hearing aid users and can reduce the production time and process stages. In this study, the effects on the shape surface were examined before and after the printing of the ear shell using a 3D printer based on the values obtained from the raw data of the DICOM images at the volumes of 0.5 mm, 1.0 mm, and 2.0 mm, respectively. Before the printing, relative relationship was compared with respect to the STL (STereoLithography) file structure; and after the printing, the intervals of the layered structure of the ear shell shape surface were compared by magnifying them using a microscope. For the STL file structure, the numbers of triangular vertices, more than five intersecting points, and maximum intersecting points were large in the order of 0.5 mm, 1.0 m, and 2.0 mm, respectively; and the triangular structure was densely distributed in the order of the bending, angle, and crest regions depending on the sinuosity of the external auditory meatus shape. As for the ear shell shape surface examined by the digital microscope, the interval of the layered structure was thick in the order of 2.0 mm, 1.0 mm, and 0.5 mm. For the STL surface structure mentioned above, the intersecting STL triangular structure was denser as the sinuosity of the 3D ear shell shape became more irregular and the volume of the raw data decreased.

  11. Effect of the STereoLithography file structure on the ear shell production for hearing aids according to DICOM images

    International Nuclear Information System (INIS)

    KIm, Hyeong Gyun

    2017-01-01

    A technique for producing the ear shell for a hearing aid using DICOM (Digital Imaging and Communication in Medicine) image and a 3D printing was studied. It is a new application method, and is an application technique that can improve the safety and infection of hearing aid users and can reduce the production time and process stages. In this study, the effects on the shape surface were examined before and after the printing of the ear shell using a 3D printer based on the values obtained from the raw data of the DICOM images at the volumes of 0.5 mm, 1.0 mm, and 2.0 mm, respectively. Before the printing, relative relationship was compared with respect to the STL (STereoLithography) file structure; and after the printing, the intervals of the layered structure of the ear shell shape surface were compared by magnifying them using a microscope. For the STL file structure, the numbers of triangular vertices, more than five intersecting points, and maximum intersecting points were large in the order of 0.5 mm, 1.0 m, and 2.0 mm, respectively; and the triangular structure was densely distributed in the order of the bending, angle, and crest regions depending on the sinuosity of the external auditory meatus shape. As for the ear shell shape surface examined by the digital microscope, the interval of the layered structure was thick in the order of 2.0 mm, 1.0 mm, and 0.5 mm. For the STL surface structure mentioned above, the intersecting STL triangular structure was denser as the sinuosity of the 3D ear shell shape became more irregular and the volume of the raw data decreased

  12. Effects of noise and working memory capacity on memory processing of speech for hearing-aid users

    OpenAIRE

    Ng, Hoi Ning, Elaine; Rudner, Mary; Lunner, Thomas; Syskind Perdersen, Michael; Rönnberg, Jerker

    2013-01-01

    Objectives: It has been shown that noise reduction algorithms can reduce the negative effects of noise on memory processing in persons with normal hearing. The objective of the present study was to investigate whether a similar effect can be obtained for persons with hearing impairment and whether such an effect is dependent on individual differences in working memory capacity. Design: A sentence-final word identification and recall (SWIR) test was conducted in two noise backgrounds with and ...

  13. 78 FR 66940 - Regulatory Requirements for Hearing Aid Devices and Personal Sound Amplification Products; Draft...

    Science.gov (United States)

    2013-11-07

    ... for such products. These inconsistent interpretations of the definitions may inadvertently result in... amplification products (PSAPs), as well as the regulatory controls that apply to each. This draft guidance is... of clarity regarding how the Agency defines a hearing aid versus a personal sound amplification...

  14. First clinical experiences with an implantable bone conduction hearing aid at the University of Amsterdam

    NARCIS (Netherlands)

    van der Hulst, R. J.; Dreschler, W. A.; Tange, R. A.

    1993-01-01

    A transcutaneous bone-conduction hearing aid was implanted in 11 patients who were not suitable for transcranial sound amplification. Audiological and surgical selection criteria were followed strictly. One device had to be explanted and minor revision surgery was needed in two cases for skin

  15. Sound exposure measurements using hearing-aid technology

    DEFF Research Database (Denmark)

    Jensen, Simon Boelt; Drastrup, Mads; Morales, Esteban Chávez

    2016-01-01

    scenarios. The purpose of this work is to document the use of a modified behind-the-ear (BTE) hearing-aid as a portable sound pressure level (SPL) meter. In order to obtain sound level measurements with a BTE device comparable to sound field values that can be used with existing risk assessment strategies...... levels of sound exposures are experienced in modern society in many different situations such as attending concerts, sport events and others. This leads to an interest in measurement devices which are discreet and simple to use, in order to assess sound exposures encountered in typical daily life......, differences due to microphone positions and the presence of a person in the measurement must be taken into account. The present study presents measurements carried out to document the characteristics of the BTE device, using the same framework presented in the ISO 11904 standard series. The responses...

  16. Classification of voice disorder in children with cochlear implantation and hearing aid using multiple classifier fusion

    Directory of Open Access Journals (Sweden)

    Tayarani Hamid

    2011-01-01

    Full Text Available Abstract Background Speech production and speech phonetic features gradually improve in children by obtaining audio feedback after cochlear implantation or using hearing aids. The aim of this study was to develop and evaluate automated classification of voice disorder in children with cochlear implantation and hearing aids. Methods We considered 4 disorder categories in children's voice using the following definitions: Level_1: Children who produce spontaneous phonation and use words spontaneously and imitatively. Level_2: Children, who produce spontaneous phonation, use words spontaneously and make short sentences imitatively. Level_3: Children, who produce spontaneous phonations, use words and arbitrary sentences spontaneously. Level_4: Normal children without any hearing loss background. Thirty Persian children participated in the study, including six children in each level from one to three and 12 children in level four. Voice samples of five isolated Persian words "mashin", "mar", "moosh", "gav" and "mouz" were analyzed. Four levels of the voice quality were considered, the higher the level the less significant the speech disorder. "Frame-based" and "word-based" features were extracted from voice signals. The frame-based features include intensity, fundamental frequency, formants, nasality and approximate entropy and word-based features include phase space features and wavelet coefficients. For frame-based features, hidden Markov models were used as classifiers and for word-based features, neural network was used. Results After Classifiers fusion with three methods: Majority Voting Rule, Linear Combination and Stacked fusion, the best classification rates were obtained using frame-based and word-based features with MVR rule (level 1:100%, level 2: 93.75%, level 3: 100%, level 4: 94%. Conclusions Result of this study may help speech pathologists follow up voice disorder recovery in children with cochlear implantation or hearing aid who are

  17. Item Response Theory Applied to Factors Affecting the Patient Journey Towards Hearing Rehabilitation

    Science.gov (United States)

    Chenault, Michelene; Berger, Martijn; Kremer, Bernd; Anteunis, Lucien

    2016-01-01

    To develop a tool for use in hearing screening and to evaluate the patient journey towards hearing rehabilitation, responses to the hearing aid rehabilitation questionnaire scales aid stigma, pressure, and aid unwanted addressing respectively hearing aid stigma, experienced pressure from others; perceived hearing aid benefit were evaluated with item response theory. The sample was comprised of 212 persons aged 55 years or more; 63 were hearing aid users, 64 with and 85 persons without hearing impairment according to guidelines for hearing aid reimbursement in the Netherlands. Bias was investigated relative to hearing aid use and hearing impairment within the differential test functioning framework. Items compromising model fit or demonstrating differential item functioning were dropped. The aid stigma scale was reduced from 6 to 4, the pressure scale from 7 to 4, and the aid unwanted scale from 5 to 4 items. This procedure resulted in bias-free scales ready for screening purposes and application to further understand the help-seeking process of the hearing impaired. PMID:28028428

  18. Recognition and Comprehension of "Narrow Focus" by Young Adults With Prelingual Hearing Loss Using Hearing Aids or Cochlear Implants.

    Science.gov (United States)

    Segal, Osnat; Kishon-Rabin, Liat

    2017-12-20

    The stressed word in a sentence (narrow focus [NF]) conveys information about the intent of the speaker and is therefore important for processing spoken language and in social interactions. The ability of participants with severe-to-profound prelingual hearing loss to comprehend NF has rarely been investigated. The purpose of this study was to assess the recognition and comprehension of NF by young adults with prelingual hearing loss compared with those of participants with normal hearing (NH). The participants included young adults with hearing aids (HA; n = 10), cochlear implants (CI; n = 12), and NH (n = 18). The test material included the Hebrew Narrow Focus Test (Segal, Kaplan, Patael, & Kishon-Rabin, in press), with 3 subtests, which was used to assess the recognition and comprehension of NF in different contexts. The following results were obtained: (a) CI and HA users successfully recognized the stressed word, with the worst performance for CI; (b) HA and CI comprehended NF less well than NH; and (c) the comprehension of NF was associated with verbal working memory and expressive vocabulary in CI users. Most CI and HA users were able to recognize the stressed word in a sentence but had considerable difficulty understanding it. Different factors may contribute to this difficulty, including the memory load during the task itself and linguistic and pragmatic abilities. https://doi.org/10.23641/asha.5572792.

  19. Language Outcomes in Young Children with Mild to Severe Hearing Loss.

    Science.gov (United States)

    Tomblin, J Bruce; Harrison, Melody; Ambrose, Sophie E; Walker, Elizabeth A; Oleson, Jacob J; Moeller, Mary Pat

    2015-01-01

    differential effects of hearing loss on morphosyntax and lexical development. Children with mild to severe hearing loss, on average, showed depressed language levels compared with peers with normal hearing who were matched on age and socioeconomic status. The degree to which CHH fell behind increased with greater severity of hearing loss. The amount of improved audibility with hearing aids was associated with differential rates of language growth; better audibility was associated with faster rates of language growth in the preschool years. Children fit early with hearing aids had better early language achievement than children fit later. However, children who were fit after 18 months of age improved in their language abilities as a function of the duration of hearing aid use. These results suggest that the language learning system remains open to experience provided by improved access to linguistic input. Performance in the domain of morphosyntax was found to be more delayed in CHH than their semantic abilities. The data obtained in this study largely support the predictions, suggesting that mild to severe hearing loss places children at risk for delays in language development. Risks are moderated by the provision of early and consistent access to well-fit hearing aids that provide optimized audibility.

  20. Localização sonora em usuários de aparelhos de amplificação sonora individual Sound localization by hearing aid users

    Directory of Open Access Journals (Sweden)

    Paula Cristina Rodrigues

    2010-06-01

    Full Text Available OBJETIVO: comparar o desempenho, no teste de localização de fontes sonoras, de usuários de aparelhos de amplificação sonora individual (AASI do tipo retroauricular e intracanal, com o desempenho de ouvintes normais, nos planos espaciais horizontal e sagital mediano, para as frequências de 500, 2.000 e 4.500 Hz; e correlacionar os acertos no teste de localização sonora com o tempo de uso dos AASI. MÉTODOS: foram testados oito ouvintes normais e 20 usuários de próteses auditivas, subdivididos em dois grupos. Um formado por 10 indivíduos usuários de próteses auditivas do tipo intracanal e o outro grupo formado por 10 usuários de próteses auditivas do tipo retroauricular. Todos foram submetidos ao teste de localização de fontes sonoras, no qual foram apresentados, aleatoriamente, três tipos de ondas quadradas, com frequências fundamentais em 0,5 kHz, 2 kHz e 4,5 kHz, na intensidade de 70 dBA. RESULTADOS: encontrou-se percentuais de acertos médios de 78,4%, 72,2% e 72,9% para os ouvintes normais, em 0,5 kHz, 2 kHz e 4,5 kHz, respectivamente e 40,1%, 39,4% e 41,7% para os usuários de aparelho de amplificação sonora individual. Quanto aos tipos de aparelhos, os usuários do modelo intracanal acertaram a origem da fonte sonora em 47,2% das vezes e os usuários do modelo retroauricular em 37,4% das vezes. Não foi observada correlação entre o percentual de acertos no teste de localização sonora e o tempo de uso da prótese auditiva. CONCLUSÃO: ouvintes normais localizam as fontes sonoras de maneira mais eficiente que os usuários de aparelho de amplificação sonora individual e, dentre estes, os que utilizam o modelo intracanal obtiveram melhor desempenho. Além disso, o tempo de uso não interferiu no desempenho para localizar a origem das fontes sonoras.PURPOSE: to compare the sound localization performance of hearing aids users, with the performance of normal hearing in the horizontal and sagittal planes, at 0.5, 2 and 4

  1. Capacitor-Free, Low Drop-Out Linear Regulator in a 180 nm CMOS for Hearing Aids

    DEFF Research Database (Denmark)

    Yosef-Hay, Yoni; Llimos Muntal, Pere; Larsen, Dennis Øland

    2016-01-01

    This paper presents a capacitor-free low dropout (LDO) linear regulator based on a new dual loop topology. The regulator utilizes the feedback loops to satisfy the challenges for hearing aid devices, which include fast transient performance and small voltage spikes under rapid load-current changes...

  2. Comparison of Gated Audiovisual Speech Identification in Elderly Hearing Aid Users and Elderly Normal-Hearing Individuals

    Science.gov (United States)

    Lidestam, Björn; Rönnberg, Jerker

    2016-01-01

    The present study compared elderly hearing aid (EHA) users (n = 20) with elderly normal-hearing (ENH) listeners (n = 20) in terms of isolation points (IPs, the shortest time required for correct identification of a speech stimulus) and accuracy of audiovisual gated speech stimuli (consonants, words, and final words in highly and less predictable sentences) presented in silence. In addition, we compared the IPs of audiovisual speech stimuli from the present study with auditory ones extracted from a previous study, to determine the impact of the addition of visual cues. Both participant groups achieved ceiling levels in terms of accuracy in the audiovisual identification of gated speech stimuli; however, the EHA group needed longer IPs for the audiovisual identification of consonants and words. The benefit of adding visual cues to auditory speech stimuli was more evident in the EHA group, as audiovisual presentation significantly shortened the IPs for consonants, words, and final words in less predictable sentences; in the ENH group, audiovisual presentation only shortened the IPs for consonants and words. In conclusion, although the audiovisual benefit was greater for EHA group, this group had inferior performance compared with the ENH group in terms of IPs when supportive semantic context was lacking. Consequently, EHA users needed the initial part of the audiovisual speech signal to be longer than did their counterparts with normal hearing to reach the same level of accuracy in the absence of a semantic context. PMID:27317667

  3. Item response theory applied to factors affecting the patient journey towards hearing rehabilitation

    Directory of Open Access Journals (Sweden)

    Michelene Chenault

    2016-11-01

    Full Text Available To develop a tool for use in hearing screening and to evaluate the patient journey towards hearing rehabilitation, responses to the hearing aid rehabilitation questionnaire scales aid stigma, pressure, and aid unwanted addressing respectively hearing aid stigma, experienced pressure from others; perceived hearing aid benefit were evaluated with item response theory. The sample was comprised of 212 persons aged 55 years or more; 63 were hearing aid users, 64 with and 85 persons without hearing impairment according to guidelines for hearing aid reimbursement in the Netherlands. Bias was investigated relative to hearing aid use and hearing impairment within the differential test functioning framework. Items compromising model fit or demonstrating differential item functioning were dropped. The aid stigma scale was reduced from 6 to 4, the pressure scale from 7 to 4, and the aid unwanted scale from 5 to 4 items. This procedure resulted in bias-free scales ready for screening purposes and application to further understand the help-seeking process of the hearing impaired.

  4. Ear malformations, hearing loss and hearing rehabilitation in children with Treacher Collins syndrome.

    Science.gov (United States)

    Rosa, Francisco; Coutinho, Miguel Bebiano; Ferreira, João Pinto; Sousa, Cecilia Almeida

    2016-01-01

    The aim of this study was to assess the main ear malformations, hearing loss and auditory rehabilitation in children with Treacher Collins syndrome. We performed a retrospective study of 9 children with Treacher Collins syndrome treated in a central hospital between January 2003 and January 2013. This study showed a high incidence of malformations of the outer and middle ear, such as microtia, atresia or stenosis of the external auditory canal, hypoplastic middle ear cavity, dysmorphic or missing ossicular chain. Most patients had bilateral hearing loss of moderate or high degree. In the individuals studied, there was functional improvement in patients with bone-anchored hearing aids in relation to conventional hearing aids by bone conduction. Treacher Collins syndrome is characterized by bilateral malformations of the outer and middle ear. Hearing rehabilitation in these children is of utmost importance, and bone-anchored hearing aids is the method of choice. Copyright © 2014 Elsevier España, S.L.U. y Sociedad Española de Otorrinolaringología y Cirugía de Cabeza y Cuello. All rights reserved.

  5. Three-year experience with the Sophono in children with congenital conductive unilateral hearing loss: tolerability, audiometry, and sound localization compared to a bone-anchored hearing aid.

    Science.gov (United States)

    Nelissen, Rik C; Agterberg, Martijn J H; Hol, Myrthe K S; Snik, Ad F M

    2016-10-01

    Bone conduction devices (BCDs) are advocated as an amplification option for patients with congenital conductive unilateral hearing loss (UHL), while other treatment options could also be considered. The current study compared a transcutaneous BCD (Sophono) with a percutaneous BCD (bone-anchored hearing aid, BAHA) in 12 children with congenital conductive UHL. Tolerability, audiometry, and sound localization abilities with both types of BCD were studied retrospectively. The mean follow-up was 3.6 years for the Sophono users (n = 6) and 4.7 years for the BAHA users (n = 6). In each group, two patients had stopped using their BCD. Tolerability was favorable for the Sophono. Aided thresholds with the Sophono were unsatisfactory, as they did not reach under a mean pure tone average of 30 dB HL. Sound localization generally improved with both the Sophono and the BAHA, although localization abilities did not reach the level of normal hearing children. These findings, together with previously reported outcomes, are important to take into account when counseling patients and their caretakers. The selection of a suitable amplification option should always be made deliberately and on individual basis for each patient in this diverse group of children with congenital conductive UHL.

  6. Unilateral hearing loss in children: a retrospective study and a review of the current literature.

    Science.gov (United States)

    Rohlfs, Anna-Katharina; Friedhoff, Johannes; Bohnert, Andrea; Breitfuss, Achim; Hess, Markus; Müller, Frank; Strauch, Anke; Röhrs, Marianne; Wiesner, Thomas

    2017-04-01

    Despite the introduction of universal newborn hearing screening (UNHS), unilateral hearing loss (UHL) is sometimes recognized late. This diagnostic delay has adverse repercussions, given the importance of binaural hearing for the development of normal auditory processing. It is incorrect to maintain that unilateral hearing is the minimum requirement for adequate speech development and that hearing aid provision is consequently unnecessary. In our retrospective study, hearing aid provision resulted in improved directional and selective hearing (quiet and noisy environments) and, compared with their chronically ill counterparts, the children in our study displayed superior health-related quality of life (HRQoL) scores in all areas. On the basis of the results, the authors conclude that even mild hearing losses (from an auditory threshold of 30 to 40 dB) should have the opportunity for hearing aid provision. A selective literature review was conducted in PubMed and textbooks and with reference to national and international guidelines. Early diagnosis and treatment of UHL have a positive effect on verbal-cognitive, linguistic, communicative, and socio-emotional development, as demonstrated by neurophysiological studies. Among the treatment modalities with differing effects on the quality of binaural hearing, cochlear implants are now used increasingly in children with hearing loss bordering on deafness. Published evidence and clinical experience support early diagnosis and treatment. Wherever feasible, hearing aid provision before or at the end of the first year of life is recommended for children with UHL. What is Known: • Almost 30 years ago, poor academic performance was reported in children with unilateral hearing loss (UHL). • Despite improvements in treatment options, it is traditionally held that unilateral hearing is the minimum requirement for adequate speech development and hearing aid provision is unnecessary. What is New: • Academic and behavioral

  7. Feasibility study of injection mouldable conductive plastic for the hearing aid applications

    DEFF Research Database (Denmark)

    Merca, Timea D.den; Lindberg, Torbjörn; Islam, Aminul

    2016-01-01

    Electrically conductive polymers can combine the advantage of plastic processing with the unique electrical properties which are usually found in metals. This article presents a feasibility study of an electrically conductive plastic for hearing aid antennas. Focus will be placed to critically......) 3D measuring system in comparison with an ideal copper antenna at 2.4 GHz. An analysis of the association between the conductive plastic processing parameters in regards to its electrical performance is discussed and evaluated....

  8. Ocena jakości życia przed i po protezowaniu narządu słuchu = The impact of hearing aids on the quality of life

    Directory of Open Access Journals (Sweden)

    Patrycja Witczak

    2016-09-01

      Ocena jakości życia przed i po protezowaniu narządu słuchu The impact of hearing aids on the quality of life     Patrycja Witczak1, Dominik Olejniczak2, Joanna Skonieczna2     1 Absolwentka kierunku Zdrowie Publiczne Wydział Nauki o Zdrowiu Warszawski Uniwersytet Medyczny   2 Warszawski Uniwersytet Medyczny Zakład Zdrowia Publicznego ul. Banacha 1a, 02-097 Warszawa     Słowa kluczowe: aparaty słuchowe, jakoś życia, niedosłuch Key words: Hearing aids, Quality of life, Hearing impairment     Streszczenie   Wprowadzenie i cel pracy: Problem niedosłuchu dotyczy ok. 12% populacji. Liczba osób dotkniętych wadą słuchu systematycznie wzrasta. Jest to ważny aspekt medyczny i społeczny. U osób u których stwierdzono niedosłuch jedną z metod rehabilitacji narządu słuchu jest użytkowanie aparatu słuchowego. Podstawowym celem protezowania narządu słuchu jest poprawa komunikowania się osoby niedosłyszącej z otoczeniem oraz zwiększenie komfortu jej życia. Głównym celem badania była ocena jakości życia i korzyści z użytkowania aparatów słuchowych u osób po 60 roku życia. Materiał i metoda: Zastosowaną metodą badawczą był sondaż diagnostyczny, techniką ankieta, a narzędziem kwestionariusz standaryzowany oceny jakości życia przed i po protezowaniu narządu słuchu. Grupą badaną jest populacja osób w wieku powyżej 60 lat. Łączna ilość osób przebadanych stanowiła grupę 60 pacjentów z wadami słuchu stosujących aparaty słuchowe. Wyniki: Narażenie środowiska pracy na hałas zadeklarowało blisko 61% badanych. Jedynie 30,5% zna podstawowe uwarunkowania zdrowia mające znaczenie w przypadku niedosłuchu. Około 75% badanych uznało, że aparat słuchowy pomógł im w życiu codziennym przynajmniej w stopniu dobrym. Wnioski: Z uwagi na dużą poprawę jakości życia po protezowaniu narządu słuchu, konieczne jest edukowanie i informowanie pacjentów w zakresie tej metody leczenia i podnoszenia jakości

  9. Comparison of Gated Audiovisual Speech Identification in Elderly Hearing Aid Users and Elderly Normal-Hearing Individuals: Effects of Adding Visual Cues to Auditory Speech Stimuli.

    Science.gov (United States)

    Moradi, Shahram; Lidestam, Björn; Rönnberg, Jerker

    2016-06-17

    The present study compared elderly hearing aid (EHA) users (n = 20) with elderly normal-hearing (ENH) listeners (n = 20) in terms of isolation points (IPs, the shortest time required for correct identification of a speech stimulus) and accuracy of audiovisual gated speech stimuli (consonants, words, and final words in highly and less predictable sentences) presented in silence. In addition, we compared the IPs of audiovisual speech stimuli from the present study with auditory ones extracted from a previous study, to determine the impact of the addition of visual cues. Both participant groups achieved ceiling levels in terms of accuracy in the audiovisual identification of gated speech stimuli; however, the EHA group needed longer IPs for the audiovisual identification of consonants and words. The benefit of adding visual cues to auditory speech stimuli was more evident in the EHA group, as audiovisual presentation significantly shortened the IPs for consonants, words, and final words in less predictable sentences; in the ENH group, audiovisual presentation only shortened the IPs for consonants and words. In conclusion, although the audiovisual benefit was greater for EHA group, this group had inferior performance compared with the ENH group in terms of IPs when supportive semantic context was lacking. Consequently, EHA users needed the initial part of the audiovisual speech signal to be longer than did their counterparts with normal hearing to reach the same level of accuracy in the absence of a semantic context. © The Author(s) 2016.

  10. [Presbycusis - Age Related Hearing Loss].

    Science.gov (United States)

    Fischer, N; Weber, B; Riechelmann, H

    2016-07-01

    Presbycusis or age related hearing loss can be defined as a progressive, bilateral and symmetrical sensorineural hearing loss due to age related degeneration of inner ear structures. It can be considered a multifactorial complex disorder with environmental and genetic factors. The molecular, electrophysiological and histological damage at different levels of the inner ear cause a progressive hearing loss, which usually affects the high frequencies of hearing. The resulting poor speech recognition has a negative impact on cognitive, emotional and social function in older adults. Recent investigations revealed an association between hearing impairment and social isolation, anxiety, depression and cognitive decline in elderly. These findings emphasize the importance of diagnosis and treating hearing loss in the elderly population. Hearing aids are the most commonly used devices for treating presbycusis. The technical progress of implantable hearing devices allows an effective hearing rehabilitation even in elderly with severe hearing loss. However, most people with hearing impairments are not treated adequately. © Georg Thieme Verlag KG Stuttgart · New York.

  11. Acceptable noise level (ANL) with Danish and non-semantic speech materials in adult hearing-aid users

    DEFF Research Database (Denmark)

    Olsen, Steen Østergaard; Lantz, Johannes; Nielsen, Lars Holme

    2012-01-01

    The acceptable noise level (ANL) test is used for quantification of the amount of background noise subjects accept when listening to speech. This study investigates Danish hearing-aid users' ANL performance using Danish and non-semantic speech signals, the repeatability of ANL, and the association...

  12. Self-Resonant Electrically Small Loop Antennas for Hearing-Aids Application

    DEFF Research Database (Denmark)

    Zhang, Jiaying; Breinbjerg, Olav

    2010-01-01

    Two novel self-resonant electrically small antennas are proposed in this paper, which are designed for hearing aids applications. They are miniaturized by using the capacitive and inductive coupling mechanism between two loops, and the antenna impedance can be matched to a specific value without...... using any additional matching network and lumped components. The dimension of the proposed antenna is 0.10λ0×0.03λ0, and it is designed to be resonant at 900 MHz. Both the analytical model and numerical simulations are discussed and explained. The antenna is also fabricated and measured in an anechoic...... chamber. The measurement methods for electrically small antennas are reported....

  13. Current amplification models of sensorineurall and conductive hearing loss

    Directory of Open Access Journals (Sweden)

    Ostojić Sanja

    2012-01-01

    Full Text Available The main function of a hearing aid is to improve auditory and language abilities of hearing impaired users. The amplification model has to be adapted according to age, degree and type of hearing loss. The goal of this paper is to analyze the current amplification models of sensorineural and conductive hearing loss which can provide a high quality of speech perception and sounds at any degree of hearing loss. The BAHA is a surgically implantable system for treatment of conductive hearing loss that works through direct bone conduction. BAHA is used to help people with chronic ear infections, congenital external auditory canal atresia and single sided deafness who cannot benefit from conventional hearing aids. The last generation of hearing aid for sensorineural hearing loss is cochlear implant. Bimodal amplification improves binaural hearing. Hearing aids alone do not make listening easier in all situations. The things that can interfere with listening are background noises, distance from a sound and reverberation or echo. The device used most often today is the Frequency Modulated (FM system.

  14. Study of the Ability of Articulation Index (Al for Predicting the Unaided and Aided Speech Recognition Performance of 25 to 65 Years Old Hearing-Impaired Adults

    Directory of Open Access Journals (Sweden)

    Ghasem Mohammad Khani

    2001-05-01

    Full Text Available Background: In recent years there has been increased interest in the use of Al for assessing hearing handicap and for measuring the potential effectiveness of amplification system. AI is an expression of proportion of average speech signal that is audible to a given patient, and it can vary between 0.0 to 1.0. Method and Materials: This cross-sectional analytical study was carried out in department of audiology, rehabilitation, faculty, IUMS form 31 Oct 98 to 7 March 1999, on 40 normal hearing persons (80 ears; 19 males and 21 females and 40 hearing impaired persons (61 ears; 36 males and 25 females, 25-65 years old with moderate to moderately severe SNI-IL The pavlovic procedure (1988 for calculating Al, open set taped standard mono syllabic word lists, and the real -ear probe- tube microphone system to measure insertion gain were used, through test-retest. Results: 1/A significant correlation was shown between the Al scores and the speech recognition scores of normal hearing and hearing-impaired group with and without the hearing aid (P<0.05 2/ There was no significant differences in age group & sex: also 3 In test-retest measures of the insertion gain in each test and 4/No significant in test-retest of speech recognition test score. Conclusion: According to these results the Al can predict the unaided and aided monosyllabic recognition test scores very well, and age and sex variables have no effect on its ability. Therefore with respect to high reliability of the Al results and its simplicity, easy -to- use, cost effective, and little time consuming for calculation, its recommended the wide use of the Al, especially in clinical situation.

  15. Treinamento auditivo formal em idosos usuários de próteses auditivas Formal auditory training in elderly hearing aid users

    Directory of Open Access Journals (Sweden)

    Elisiane Crestani de Miranda

    2008-12-01

    Full Text Available A implantação de programas de reabilitação para o deficiente auditivo idoso é de grande importância. OBJETIVO: Verificar a eficácia de um programa de treinamento auditivo formal em idosos que receberam próteses auditivas há no mínimo três meses, por meio de testes de reconhecimento de fala e questionário de auto-avaliação. MÉTODO: Estudo de coorte contemporânea longitudinal. Foram selecionados 13 idosos usuários de próteses auditivas intra-aurais em adaptação binaural, de ambos os sexos, com idade média de 65,30 anos. Este grupo foi subdividido aleatoriamente em Grupo Experimental e Grupo Controle, por meio de sorteio. O Grupo Experimental foi submetido a sete sessões de treinamento auditivo formal, visando estimular as habilidades auditivas de fechamento auditivo, memória, atenção, figura-fundo e integração binaural. Os participantes foram avaliados por três testes comportamentais e um questionário de auto-avaliação. RESULTADOS: Os idosos do Grupo Experimental apresentaram desempenho significantemente melhor nas avaliações após o treinamento auditivo e também em relação ao Grupo Controle. CONCLUSÃO: O programa de treinamento auditivo em cabina acústica, associado ao uso de próteses auditivas, melhora o desempenho das habilidades de reconhecimento de fala e reduz a percepção do handicap auditivo de idosos usuários de próteses auditivas intra-aurais.It is of paramount importance to install hearing rehabilitation programs for the elderly. AIM: to check the efficacy of a forma auditory training program for elderly patients fitted with hearing aids for at least three months, by means of speech recognition tests and self-assessment questionnaires. METHODS: longitudinal contemporary cohort study. We selected 13 elderly hearing aid users, using intra-canal hearing aids in both ears, from both genders, with average age of 65.3 years. This group was randomly divided in Experiment Group and Control Group. The

  16. Challenges in management of childhood sensorineural hearing loss in sub-Saharan Africa, Nigeria.

    Science.gov (United States)

    Lasisi, O A; Ayodele, J K; Ijaduola, G T A

    2006-04-01

    The evaluation of a hearing-impaired child attempts to determine the aetiology, the degree of hearing loss and intervention to aid speech and language. This remains a challenge to practising otolaryngologists, especially in the developing countries as 85-90% of causes of hearing losses were never discovered leading to delayed intervention and irreversible effects. In a review of children presenting at the otolaryngology outpatient in the University College Hospital, Ibadan, Nigeria, sensorineural hearing loss was found in 103, giving a hospital prevalence rate of 14%, we still perceived this figure to be unrepresentatively and low, probably due to poor access to medicare, poverty and other factors. Genetic factor accounted for 25%, followed by measles infections 13% and meningitis 8%. About 60% of them had educationally significant hearing loss at presentation. Access to hearing aid was poor as only 12.5% of the patients could afford it and the rest were managed by deaf training. We conclude by suggesting an audiologic programme which has the comprehensive function of neonatal and infant hearing screening, subsidized hearing aid services and hearing rehabilitation surgery.

  17. Feedback suppression in digital hearing instruments

    DEFF Research Database (Denmark)

    Ma, Guilin

    . Methods to extract the fixed model are proposed and proved to be effective in representing the invariant part of the feedback path. Based on the investigation of the dynamic changes of the feedback path in adverse situations, for example when the user picks up the telephone handset, a reflection model...... canceller with filtered-X adaptation by injecting nearly inaudible noise. The second approach uses a linear predicative coding based vocoder to synthesize the hearing-aid output in order to decorrelate the hearing-aid output signal and the desired input signal. In the end, a discussion about the use...

  18. The effect of functional hearing loss and age on long- and short-term visuospatial memory: evidence from the UK biobank resource.

    Science.gov (United States)

    Rönnberg, Jerker; Hygge, Staffan; Keidser, Gitte; Rudner, Mary

    2014-01-01

    The UK Biobank offers cross-sectional epidemiological data collected on >500,000 individuals in the UK between 40 and 70 years of age. Using the UK Biobank data, the aim of this study was to investigate the effects of functional hearing loss and hearing aid usage on visuospatial memory function. This selection of variables resulted in a sub-sample of 138,098 participants after discarding extreme values. A digit triplets functional hearing test was used to divide the participants into three groups: poor, insufficient and normal hearers. We found negative relationships between functional hearing loss and both visuospatial working memory (i.e., a card pair matching task) and visuospatial, episodic long-term memory (i.e., a prospective memory task), with the strongest association for episodic long-term memory. The use of hearing aids showed a small positive effect for working memory performance for the poor hearers, but did not have any influence on episodic long-term memory. Age also showed strong main effects for both memory tasks and interacted with gender and education for the long-term memory task. Broader theoretical implications based on a memory systems approach will be discussed and compared to theoretical alternatives.

  19. The Effect of Functional Hearing Loss and Age on Long- and Short-term Visuospatial Memory: Evidence from the UK Biobank Resource

    Directory of Open Access Journals (Sweden)

    Jerker eRönnberg

    2014-12-01

    Full Text Available The UK Biobank offers cross-sectional epidemiological data collected on > 500 000 individuals in the UK between 40 and 70 years of age. Using the UK Biobank data, the aim of this study was to investigate the effects of functional hearing loss and hearing aid usage on visuospatial memory function. This selection of variables resulted in a sub-sample of 138 098 participants after discarding extreme values. A digit triplets functional hearing test was used to divide the participants into three groups: poor, insufficient and normal hearers. We found negative relationships between functional hearing loss and both visuospatial working memory (i.e., a card pair matching task and visuospatial, episodic long-term memory (i.e., a prospective memory task, with the strongest association for episodic long-term memory. The use of hearing aids showed a small positive effect for working memory performance for the poor hearers, but did not have any influence on episodic long-term memory. Age also showed strong main effects for both memory tasks and interacted with gender and education for the long-term memory task. Broader theoretical implications based on a memory systems approach will be discussed and compared to theoretical alternatives.

  20. Pronto atendimento a usuários de dispositivos de amplificação sonora Emergency care to users of hearing aids

    Directory of Open Access Journals (Sweden)

    Tiago de Melo Araujo

    2011-12-01

    Full Text Available OBJETIVO: Estabelecer características demográficas e audiológicas de sujeitos usuários de aparelhos de amplificação sonora individuais (AASI que solicitaram retorno em um Serviço de Saúde Auditiva e identificar e analisar os motivos do retorno e condutas geradas durante o Pronto Atendimento (PA. MÉTODOS: Os participantes foram 440 sujeitos de idade superior a três anos, com diagnóstico e concessão do AASI no serviço onde foi realizada a pesquisa. Características demográficas, audiológicas e referentes ao uso do AASI foram coletadas em prontuários e ficha específica para o PA. Os dados obtidos foram analisados por meio de estatística descritiva e inferencial. RESULTADOS: O grupo estudado foi caracterizado, em sua maioria, por indivíduos do gênero feminino, idosos, grau de escolaridade no ensino fundamental incompleto, perda auditiva de grau moderado e perda auditiva do tipo neurossensorial bilateral. Quanto ao uso do AASI, a maioria dos sujeitos utilizava aparelho do tipo retroauricular com adaptação binaural. Quanto ao tempo de uso, mais de 70% utilizava o AASI pela primeira vez, 38% o fazia por um período de até 12 meses, e mais de 65% por um período maior que oito horas diárias. As condutas ajuste do AASI e orientação foram mais frequentes para sujeitos com menor tempo de uso do aparelho, enquanto as condutas assistência técnica e reposição, foram mais comuns para os sujeitos com maior tempo de uso. CONCLUSÃO: Conhecer características de pacientes usuários de AASI, assim como os motivos do retorno e condutas geradas, contribui para melhor organização e qualidade do serviço prestado.PURPOSE: To establish the demographic and audiological characteristics of subjects users of hearing aids (HA that requested a return at a Hearing Health Service, and to identify and analyze the reasons for the return and conducts generated during the Emergency Care (EC. METHODS: Participants were 440 subjects older than three

  1. Vibrant Soundbridge rehabilitation of conductive and mixed hearing loss.

    Science.gov (United States)

    Lüers, Jan-Christoffer; Hüttenbrink, Karl-Bernd

    2014-12-01

    The Vibrant Soundbridge is the world's most often implanted active middle ear implant or hearing aid. During the last few years, the device indications have expanded from sensorineural hearing loss to conductive and mixed hearing loss. Titanium couplers have led to improved contact of the floating mass transducer with the middle ear structures. The resulting hearing gain is satisfying for most patients, but so far, there is no clear audiologic advantage over conventional hearing aids. Currently, the indications are mainly related to intolerance of conventional hearing aids (eg, chronic otitis externa), severe mixed hearing loss with a destructed middle ear and certain medical diagnosis (eg, congenital atresia). Copyright © 2014 Elsevier Inc. All rights reserved.

  2. Hearing Preservation after Cochlear Implantation: UNICAMP Outcomes

    Directory of Open Access Journals (Sweden)

    Guilherme Machado de Carvalho

    2013-01-01

    Full Text Available Background. Electric-acoustic stimulation (EAS is an excellent choice for people with residual hearing in low frequencies but not high frequencies and who derive insufficient benefit from hearing aids. For EAS to be effective, subjects' residual hearing must be preserved during cochlear implant (CI surgery. Methods. We implanted 6 subjects with a CI. We used a special surgical technique and an electrode designed to be atraumatic. Subjects' rates of residual hearing preservation were measured 3 times postoperatively, lastly after at least a year of implant experience. Subjects' aided speech perception was tested pre- and postoperatively with a sentence test in quiet. Subjects' subjective responses assessed after a year of EAS or CI experience. Results. 4 subjects had total or partial residual hearing preservation; 2 subjects had total residual hearing loss. All subjects' hearing and speech perception benefited from cochlear implantation. CI diminished or eliminated tinnitus in all 4 subjects who had it preoperatively. 5 subjects reported great satisfaction with their new device. Conclusions. When we have more experience with our surgical technique we are confident we will be able to report increased rates of residual hearing preservation. Hopefully, our study will raise the profile of EAS in Brazil and Latin/South America.

  3. A home education program for older adults with hearing impairment and their significant others: a randomized trial evaluating short- and long-term effects

    NARCIS (Netherlands)

    Kramer, S.E.; Allessie, G.H.; Dondorp, A.W.; Zekveld, A.A.; Kapteyn, T.S.

    2005-01-01

    This paper addresses the development and effectiveness of a home education program. The program, designed for hearing-impaired elders and their significant others (SO), deals with communication strategies and speech reading. Participants were randomly assigned to a training group (hearing aid

  4. Acompanhamento da adaptação de próteses auditivas em crianças surdas Evaluating the adaptation of hearing aids for hearing impaired children

    Directory of Open Access Journals (Sweden)

    Bianca Pinheiro Lanzetta

    2010-06-01

    Full Text Available OBJETIVOS: descrever as características audiológicas e sociais de crianças surdas e avaliar a incidência de retornos para acompanhamento no Programa de Saúde Auditiva. MÉTODOS: foram analisados os prontuários de crianças que receberam as próteses auditivas pelo Programa de Saúde Auditiva, em Vila Velha - Espírito Santo. A população estudada foi constituída por 50 crianças, na faixa etária de zero a oito anos, de ambos os sexos, com diagnóstico de perda auditiva sensorioneural de grau leve a profundo. O protocolo de pesquisa foi preenchido a partir dos dados de prontuários para a obtenção das informações desejadas. RESULTADOS: a solicitação de retorno pelo Serviço Social propiciou o comparecimento de quase da metade da população (44%; os demais achados foram indicativos da associação entre o retorno para acompanhamento e a rotina escolar. CONCLUSÕES: o referido programa atinge predominantemente famílias com rendimento mensal entre um e dois salários mínimos; o diagnóstico da surdez ocorre entre dois e três anos de idade cronológica neste estudo; a época da primeira adaptação de próteses auditivas, aos seis anos de idade, é bastante tardia; o contato com os pais, por meio do Serviço Social, viabiliza o acompanhamento proposto, influenciado positivamente também pela rotina escolar.PURPOSE: to describe the compliance and attitudes of hearing-impaired children towards the treatment and support offered by the Hearing Health Program, a public health endeavor, and assessing patients’ returns for follow-ups. METHODS: participants consisted of fifty children aged from 0 to 8 years, with a diagnosis of mild to severe sensorineural hearing loss. The children received the hearing aids from the Hearing Health Program, in Vila Velha, in the state of Espírito Santo, Brazil. The research protocol was completed using both medical records and a socio-economical profile survey of the affected children, including the

  5. Approximated affine projection algorithm for feedback cancellation in hearing aids.

    Science.gov (United States)

    Lee, Sangmin; Kim, In-Young; Park, Young-Cheol

    2007-09-01

    We propose an approximated affine projection (AP) algorithm for feedback cancellation in hearing aids. It is based on the conventional approach using the Gauss-Seidel (GS) iteration, but provides more stable convergence behaviour even with small step sizes. In the proposed algorithm, a residue of the weighted error vector, instead of the current error sample, is used to provide stable convergence. A new learning rate control scheme is also applied to the proposed algorithm to prevent signal cancellation and system instability. The new scheme determines step size in proportion to the prediction factor of the input, so that adaptation is inhibited whenever tone-like signals are present in the input. Simulation results verified the efficiency of the proposed algorithm.

  6. Acoustic properties of vocal singing in prelingually-deafened children with cochlear implants or hearing aids.

    Science.gov (United States)

    Mao, Yitao; Zhang, Mengchao; Nutter, Heather; Zhang, Yijing; Zhou, Qixin; Liu, Qiaoyun; Wu, Weijing; Xie, Dinghua; Xu, Li

    2013-11-01

    The purpose of the present study was to investigate vocal singing performance of hearing-impaired children with cochlear implants (CI) and hearing aids (HA) as well as to evaluate the relationship between demographic factors of those hearing-impaired children and their singing ability. Thirty-seven prelingually-deafened children with CIs and 31 prelingually-deafened children with HAs, and 37 normal-hearing (NH) children participated in the study. The fundamental frequencies (F0) of each note in the recorded songs were extracted and the duration of each sung note was measured. Five metrics were used to evaluate the pitch-related and rhythm-based aspects of singing accuracy. Children with CIs and HAs showed significantly poorer performance in either the pitch-based assessments or the rhythm-based measure than the NH children. No significant differences were seen between the CI and HA groups in all of these measures except for the mean deviation of the pitch intervals. For both hearing-impaired groups, length of device use was significantly correlated with singing accuracy. There is a marked deficit in vocal singing ability either in pitch or rhythm accuracy in a majority of prelingually-deafened children who have received CIs or fitted with HAs. Although an increased length of device use might facilitate singing performance to some extent, the chance for the hearing-impaired children fitted with either HAs or CIs to reach high proficiency in singing is quite slim. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  7. The current status of audiologic rehabilitation for profound unilateral sensorineural hearing loss.

    Science.gov (United States)

    Bishop, Charles E; Eby, Thomas L

    2010-03-01

    Audiologic rehabilitation of individuals with profound unilateral sensorineural hearing loss (USNHL) has traditionally been limited to the use of air-conduction contralateral routing of sound (CROS) hearing aids. Treatment for these individuals has expanded with new applications of the bone-anchored hearing aid (BAHA), transcranial hearing aid (t-CROS), and the cochlear implant. In this article, the authors review the literature that addresses these various treatment options. Contemporary review Historical information is available that describes the limited efficacy of air-conduction CROS hearing aids in lifting hearing handicap associated with USNHL. Current investigations on providing cross hearing are generally focused on use of the BAHA. Little is known at present whether new developments in hearing aid technology can improve on conventional air-conduction CROS or t-CROS approaches. Interestingly, the cochlear implant seems to be a viable option for individuals with USNHL and tinnitus who also have intact auditory nerve pathways. There is indication in the literature that BAHA provides greater relief of hearing handicap associated with USNHL than CROS hearing aids; however, both have been found to provide limited patient satisfaction and seemingly fall short of restoring true sound localization. Adequate trials have not been performed comparing BAHA with the best CROS hearing aid technology. Transcranial hearing aids and cochlear implants are experimental methods to treat USNHL and hold promise, although there remains a lack of studies available to fully support this.

  8. Interventions following hearing screening in adults: a systematic descriptive review.

    Science.gov (United States)

    Pronk, Marieke; Kramer, Sophia E; Davis, Adrian C; Stephens, Dafydd; Smith, Pauline A; Thodi, Chryssoula; Anteunis, Lucien J C; Parazzini, Marta; Grandori, Ferdinando

    2011-09-01

    Adult hearing screening may be a solution to the under-diagnosis and under-treatment of hearing loss in adults. Limited use and satisfaction with hearing aids indicate that consideration of alternative interventions following hearing screening may be needed. The primary aim of this study is to provide an overview of all intervention types that have been offered to adult (≥ 18 years) screen-failures. Systematic literature review. Articles were identified through systematic searches in PubMed, EMBASE, Cinahl, the Cochrane Library, private libraries, and through reference checking. Of the initial 3027 papers obtained from the searches, a total of 37 were found to be eligible. The great majority of the screening programmes (i.e. 26) referred screen-failures to a hearing specialist without further rehabilitation being specified. Most of the others (i.e. seven) led to the provision of hearing aids. Four studies offered alternative interventions comprising communication programme elements (e.g. speechreading, hearing tactics) or advice on environmental aids. Interventions following hearing screening generally comprised referral to a hearing specialist or hearing aid rehabilitation. Some programmes offered alternative rehabilitation options. These may be valuable as an addition to or replacement of hearing aid rehabilitation. It is recommended that this be addressed in future research.

  9. Evaluation of State-of-the-Art Acoustic Feedback Cancellation Systems for Hearing Aids

    DEFF Research Database (Denmark)

    Guo, Meng; Jensen, Søren Holdt; Jensen, Jesper

    2013-01-01

    This research evaluates four state-of-the-art acoustic feedback cancellation systems in hearing aids in terms of the cancellation performance, sound quality degradation, and computational complexity. The authors compared a traditional full-band system to a system with a prediction error method...... in a full band, a subband system, a subband system with frequency shifting, and a recently proposed subband system with a novel probe noise deployment. All systems outperformed the traditional full-band system in cancellation performance, especially the subband system with probe noise is most effective...... for cancellation. However, in all cases there was a trade-off between performance and computational cost. With a 3-times increase in computation load, the probe noise based cancellation system can be realized that functions even in the most challenging feedback situation....

  10. Bone-anchored hearing aid (BAHA: indications, functional results, and comparison with reconstructive surgery of the ear

    Directory of Open Access Journals (Sweden)

    Bento, Ricardo Ferreira

    2012-01-01

    Full Text Available Introduction: The bone-anchored hearing aid (BAHA is a bone conduction hearing device that transmits sound directly into the inner ear. It is mainly used in patients with conductive hearing loss associated with aural atresia, but it is also used in those with mixed and sensorineural hearing loss. Goals: To review the main indications for BAHA, to analyze the audiometric results and its benefits for patients and compare them with other treatment modalities, and to compare the literature data with our sample of 13 patients. Method: The research was performed using a database covering works in English, Spanish, and Portuguese, with no limitations in the years when the procedures were performed. We compared the literature data with our results for the 13 patients who underwent BAHA implantation between the years 2000 and 2009. Results: Most of the studies showed that BAHA has great advantages over reconstructive surgery in terms of hearing results, complications, and disease recurrence. The postoperative results for our 13 patients were satisfactory and comparable with the results from the literature, with closure of the air-bone gap in 7 patients and achieving an air-bone gap of 10 dB in 6 patients. No postoperative complications were observed. Conclusion: BAHA is a better treatment option than reconstructive surgery for patients with bilateral deafness. It is a relatively simple surgical procedure with few complications and good hearing results. Recent studies have examined its use in conductive and unilateral sensorineural hearing loss.

  11. Experiences of an Internet-based aural rehabilitation (IAR) program for hearing aid users: a qualitative study.

    Science.gov (United States)

    Malmberg, Milijana; Sundewall Thorén, Elisabet; Öberg, Marie; Lunner, Thomas; Andersson, Gerhard; Kähäri, Kim

    2018-04-24

    Internet interventions for hearing aid (HA) users have been shown to be effective in helping persons with hearing problems. As earlier research refers to objective data on these effects, little is known about how participants experience the Internet interventions subjectively. The aim of the present study was to explore participants' experiences of an Internet-based aural rehabilitation (IAR) program for HA-users, and to explore the possible subjective benefits of such a program. A qualitative exploratory design was implemented involving semi-structured telephone interviews. The interviews were transcribed and analysed using content analysis. Interviews were conducted with 20 participants (9 men and 11 women) who had completed an IAR program for HA-users. The participants were 57-81 years old and had used HAs for 2-25 years. The results are organised in three main categories: general experiences associated with participating in the program, knowledge obtained from the program and perceived impact of taking part in the program. The overall results indicate positive experiences of the IAR program, and an overreaching theme of increased self-esteem was identified. The findings provide some valuable information for developers of future IAR programs.

  12. The merit of using silicon for the development of hearing aid microphones and intraocular pressure sensors

    NARCIS (Netherlands)

    Bergveld, Piet

    1994-01-01

    An important design rule for a hearing aid is the requirement of a large signal to noise ratio, which is mainly determined by that of the microphone and its preamplifier. It will be shown that in order to increase the signal to noise ratio it is favourable to integrate the preamplifier with the

  13. Case Factors Affecting Hearing Aid Recommendations by Hearing Care Professionals

    DEFF Research Database (Denmark)

    Gioia, Carmine; Ben-Akiva, Moshe; Jørgensen, Ole

    2015-01-01

    in subjective decision-making as regards the technology level recommendation made by professionals. Purpose: The objective of this study is to gain insight into the decision-making criteria utilized by professionals when recommending HI technology levels to hearing-impaired patients.......Background: Professional recommendations to patients concerning hearing instrument (HI) technology levels are not currently evidence-based. Pre-fitting parameters have not been proven to be the primary indicators for optimal patient outcome with different HI technology levels. This results...

  14. Tone, rhythm, and timbre perception in school-age children using cochlear implants and hearing aids.

    Science.gov (United States)

    Innes-Brown, Hamish; Marozeau, Jeremy P; Storey, Christine M; Blamey, Peter J

    2013-10-01

    Children with hearing impairments, especially those using hearing devices such as the cochlear implant (CI) or hearing aid (HA), are sometimes not encouraged to attend music classes, as they or their parents and teachers may be unsure whether the child can perform basic musical tasks. The objective of the current study was to provide a baseline for the performance of children using CIs and HAs on standardized tests of rhythm and pitch perception as well as an instrument timbre identification task. An additional aim was to determine the effect of structured music training on these measures during the course of a school year. The Intermediate Measures of Music Audiation (IMMA) Tonal and Rhythmic subtests were administered four times, with 6 wk between tests. All children in the study were also enrolled in "Music Club" teaching sessions. Measures were compared between groups and across the four testing sessions. Twenty children from a single school in Melbourne, Australia, were recruited. Eleven (four girls) had impaired hearing, including six with a unilateral CI or CI and HA together (two girls) and five with bilateral HAs (two girls). Nine were normally hearing, selected to match the age and gender of the hearing-impaired children. Ages ranged from 9-13 yr. All children participated in a weekly Music Club--a 45 min session of musical activities based around vocal play and the integration of aural, visual, and kinesthetic modes of learning. Audiological data were collected from clinical files. IMMA scores were converted to percentile ranks using published norms. Between-group differences were tested using repeated-measures analysis of variance, and between-session differences were tested using a linear mixed model. Linear regression was used to model the effect of hearing loss on the test scores. In the first session, normally hearing children had a mean percentile rank of ∼50 in both the Tonal and Rhythmic subtests of the IMMA. Children using CIs showed trends

  15. Research on Hearing and Balance--Current and Future Developments.

    Science.gov (United States)

    Snow, James B., Jr.

    1997-01-01

    This article reviews current research that has located disease genes causing hearing impairments, discovered the ability of sensory cells of the inner ear to regenerate, developed vaccines to prevent otitis media, developed programmable hearing aids, improved cochlear implants, and demonstrated the positive effects of physical therapy with balance…

  16. Enhancing Auditory Selective Attention Using a Visually Guided Hearing Aid

    Science.gov (United States)

    2017-01-01

    Purpose Listeners with hearing loss, as well as many listeners with clinically normal hearing, often experience great difficulty segregating talkers in a multiple-talker sound field and selectively attending to the desired “target” talker while ignoring the speech from unwanted “masker” talkers and other sources of sound. This listening situation forms the classic “cocktail party problem” described by Cherry (1953) that has received a great deal of study over the past few decades. In this article, a new approach to improving sound source segregation and enhancing auditory selective attention is described. The conceptual design, current implementation, and results obtained to date are reviewed and discussed in this article. Method This approach, embodied in a prototype “visually guided hearing aid” (VGHA) currently used for research, employs acoustic beamforming steered by eye gaze as a means for improving the ability of listeners to segregate and attend to one sound source in the presence of competing sound sources. Results The results from several studies demonstrate that listeners with normal hearing are able to use an attention-based “spatial filter” operating primarily on binaural cues to selectively attend to one source among competing spatially distributed sources. Furthermore, listeners with sensorineural hearing loss generally are less able to use this spatial filter as effectively as are listeners with normal hearing especially in conditions high in “informational masking.” The VGHA enhances auditory spatial attention for speech-on-speech masking and improves signal-to-noise ratio for conditions high in “energetic masking.” Visual steering of the beamformer supports the coordinated actions of vision and audition in selective attention and facilitates following sound source transitions in complex listening situations. Conclusions Both listeners with normal hearing and with sensorineural hearing loss may benefit from the acoustic

  17. A 1.4-V 48-μW current-mode front-end circuit for analog hearing aids with frequency compensation

    International Nuclear Information System (INIS)

    Wang Xiaoyu; Yang Haigang; Li Fanyang; Yin Tao; Liu Fei

    2012-01-01

    A current-mode front-end circuit with low voltage and low power for analog hearing aids is presented. The circuit consists of a current-mode AGC (automatic gain control) and a current-mode adaptive filter. Compared with its conventional voltage-mode counterparts, the proposed front-end circuit has the identified features of frequency compensation based on the state space theory and continuous gain with an exponential characteristic. The frequency compensation which appears only in the DSP unit of the digital hearing aid can upgrade the performance of the analog hearing aid in the field of low-frequency hearing loss. The continuous gain should meet the requirement of any input amplitude level, while its exponential characteristic leads to a large input dynamic range in accordance with the dB SPL (sound pressure level). Furthermore, the front-end circuit also provides a discrete knee point and discrete compression ratio to allow for high calibration flexibility. These features can accommodate users whose ears have different pain thresholds. Taking advantage of the current-mode technique, the MOS transistors work in the subthreshold region so that the quiescent current is small. Moreover, the input current can be compressed to a low voltage signal for processing according to the compression principle from the current-domain to the voltage-domain. Therefore, the objective of low voltage and low power (48 μW at 1.4 V) can be easily achieved in a high threshold-voltage CMOS process of 0.35 μm (V TON + |V TOP |≈ 1.35 V). The THD is below −45 dB. The fabricated chip only occupies the area of 1 × 0.5 mm 2 and 1 × 1 mm 2 .

  18. Auditory profiling and hearing-aid satisfaction in hearing-aid candidates

    DEFF Research Database (Denmark)

    Thorup, Nicoline; Santurette, Sébastien; Jørgensen, Søren

    2016-01-01

    by default. This study aimed at identifying clinically relevant tests that may serve as an informative addition to the audiogram and which may relate more directly to HA satisfaction than the audiogram does. METHODS: A total of 29 HI and 26 normal-hearing listeners performed tests of spectral and temporal...... their audiogram. Measures of temporal resolution or speech perception in both stationary and fluctuating noise could be relevant measures to consider in an extended auditory profile. FUNDING: The study was supported by Grosserer L.F. Foghts Fond. TRIAL REGISTRATION: The protocol was approved by the Science Ethics...

  19. Extracting the invariant model from the feedback paths of digital hearing aids

    DEFF Research Database (Denmark)

    Ma, Guilin; Gran, Fredrik; Jacobsen, Finn

    2011-01-01

    environments given a specific type of hearing aids. Based on this observation, a feedback path model that consists of an invariant model and a variant model is proposed. A common-acoustical-pole and zero model-based approach and an iterative least-square search-based approach are used to extract the invariant...... model from a set of impulse responses of the feedback paths. A hybrid approach combining the two methods is also proposed. The general properties of the three methods are studied using artificial datasets, and the methods are cross-validated using the measured feedback paths. The results show...

  20. A satisfação e o desempenho de usuários de próteses auditivas atendidos em um programa de atenção à saúde auditiva Satisfaction and performance of hearing aids users assisted in a Hearing Health Care Program

    Directory of Open Access Journals (Sweden)

    Aline da Silva Lopes

    2011-08-01

    Noise was carried out in sound field through the Portuguese Sentences Lists test; the satisfaction questionnaire, International Outcome Inventory for Hearing Aids (IOI-HA, was also applied. The tests were carried out in the same session, in two distinctive timeframes: the first one without using hearing aids, and the second one using hearing aids. RESULTS: there was a meaningful difference in both groups regarding the procedure carried out in silence. Although the performance in noise has not resulted in meaningful improvement, the patients had positive scores in the questionnaire. When comparing both groups, no significant difference in performance and satisfaction was observed. CONCLUSION: the meaningful improvement in silence agrees with the patients report. The questionnaire showed that most patients referred as making effective use of the hearing aids and having a very satisfying benefit. Although some patients referred a moderate or great residual difficulty, most of them considered that using hearing aids is really worthy.

  1. Statistical Shape Analysis of the Human Ear Canal with Application to In-the-Ear Hearing Aid Design

    DEFF Research Database (Denmark)

    Paulsen, Rasmus Reinhold

    2004-01-01

    This thesis is about the statistical shape analysis of the human ear canal with application to the mechanical design of in-the-ear hearing aids. Initially, it is described how a statistical shape model of the human ear canal is built based on a training set of laser-scanned ear impressions. A thin...

  2. Predicting effects of hearing-instrument signal processing on consonant perception

    DEFF Research Database (Denmark)

    Zaar, Johannes; Schmitt, Nicola; Derleth, Ralph-Peter

    2017-01-01

    –1064] that combines an auditory processing front end with a correlation-based template-matching back end. In terms of HA processing, effects of strong nonlinear frequency compression and impulse-noise suppression were measured in 10 NH listeners using consonant-vowel stimuli. Regarding CI processing, the consonant......This study investigated the influence of hearing-aid (HA) and cochlear-implant (CI) processing on consonant perception in normal-hearing (NH) listeners. Measured data were compared to predictions obtained with a speech perception model [Zaar and Dau (2017). J. Acoust. Soc. Am. 141, 1051...... perception data from DiNino et al. [(2016). J. Acoust. Soc. Am. 140, 4404-4418] were considered, which were obtained with noise-vocoded vowel-consonant-vowel stimuli in 12 NH listeners. The inputs to the model were the same stimuli as were used in the corresponding experiments. The model predictions obtained...

  3. Transcultural adaptation to Spanish of the instrument "Effectiveness of Auditory Rehabilitation" for the assessment of quality of life in patients using hearing aids.

    Science.gov (United States)

    Cardemil, Felipe; Esquivel, Patricia; Aguayo, Lorena; Barría, Tamara; Fuente, Adrian; Carvajal, Rocío; Fromín, Rose; Villalobos, Iván; Yueh, Bevan

    2013-01-01

    It is becoming increasingly important to have reliable and valid questionnaires. This becomes especially important when evaluating hearing loss. the "Effectiveness of Auditory Rehabilitation" (EAR) questionnaire for the Spanish-speaking population. This instrument assesses quality of life and hearing aspects in patients using hearing aids. Cross-sectional validation study. A cultural adaptation through the use of English to Spanish translations and re-translations was carried out. The validity and reliability of the newly adapted instrument were evaluated. A total of 69 individuals (44 older adults and 25 younger adults) were examined. The pure-tone averages (PTA, 500, 1,000 and 2,000 Hz) were 47.3 dB HL and 47.1 dB HL for the left and right ears, respectively. The mean maximum speech discrimination in silence for monosyllables were 83.3% and 82.9% for the left and right ears, respectively. Internal consistency presented Cronbach alpha values of 0.85 and 0.77 for the internal and external dimensions, respectively. The intraclass correlation coefficients were 0.80 for the internal module and 0.85 for the external module. Construct validity reported a correlation coefficient of 0.71 at baseline and 0.76 at 3 months after the initial assessment for the internal module, and 0.62 at baseline and 0.74 at 3 months after the initial assessment for the external module. The size effects were 1.3 and 1.1 for the internal and external modules, respectively. The Spanish version of the EAR questionnaire seems to be a reliable and valid instrument. The evaluation of audiological aspects, as well as aspects relating to aesthetics and comfort are the main strengths of this instrument. Finally, the EAR scale is more sensitive to change than other scales. Copyright © 2013 Elsevier España, S.L. All rights reserved.

  4. A Profiling System for the Assessment of Individual Needs for Rehabilitation With Hearing Aids

    Directory of Open Access Journals (Sweden)

    Wouter A. Dreschler

    2016-10-01

    Full Text Available This study focuses on the development of a profiling system to specify the needs of hearing-aid candidates. As a basis for the profile of compensation needs, we used a slightly modified version of the Amsterdam Inventory of Disability and Handicap, combined with the well-known Client-Oriented Scale of Improvement (COSI. The first questionnaire results in scores for six audiological dimensions: detection, speech in quiet, speech in noise, localization, focus or discrimination, and noise tolerance. The goal of this study was to determine whether the six dimensions derived from the disability questionnaire are appropriate to also categorize individual COSI targets. The results show a good agreement between eight audiologists in the categorization of COSI goals along the six dimensions. The results per dimension show that the dimension focus or discrimination can be regarded as superfluous. Possible additional dimensions were tinnitus and listening effort. The results indicate that it is possible to translate individual user needs (administered using COSI into more general dimensions derived from a disability questionnaire. This allows to summarize the compensation needs for individual patients in a profile of general dimensions, based on the degree of disability and the individual user needs. This profile can be used as a starting point in hearing aid selection. This approach also offers a well-structured method for the evaluation of the postfitting results.

  5. The effect of functional hearing loss and age on long- and short-term visuospatial memory: evidence from the UK biobank resource

    OpenAIRE

    Rönnberg, Jerker; Hygge, Staffan; Keidser, Gitte; Rudner, Mary

    2014-01-01

    The UK Biobank offers cross-sectional epidemiological data collected on > 500 000 individuals in the UK between 40 and 70 years of age. Using the UK Biobank data, the aim of this study was to investigate the effects of functional hearing loss and hearing aid usage on visuospatial memory function. This selection of variables resulted in a sub-sample of 138 098 participants after discarding extreme values. A digit triplets functional hearing test was used to divide the participants into three g...

  6. The Need for Improved Detection and Management of Adult-Onset Hearing Loss in Australia

    Directory of Open Access Journals (Sweden)

    Catherine M. McMahon

    2013-01-01

    Full Text Available Adult-onset hearing loss is insidious and typically diagnosed and managed several years after onset. Often, this is after the loss having led to multiple negative consequences including effects on employment, depressive symptoms, and increased risk of mortality. In contrast, the use of hearing aids is associated with reduced depression, longer life expectancy, and retention in the workplace. Despite this, several studies indicate high levels of unmet need for hearing health services in older adults and poor use of prescribed hearing aids, often leading to their abandonment. In Australia, the largest component of financial cost of hearing loss (excluding the loss of well-being is due to lost workplace productivity. Nonetheless, the Australian public health system does not have an effective and sustainable hearing screening strategy to tackle the problem of poor detection of adult-onset hearing loss. Given the increasing prevalence and disease burden of hearing impairment in adults, two key areas are not adequately met in the Australian healthcare system: (1 early identification of persons with chronic hearing impairment; (2 appropriate and targeted referral of these patients to hearing health service providers. This paper reviews the current literature, including population-based data from the Blue Mountains Hearing Study, and suggests different models for early detection of adult-onset hearing loss.

  7. Hearing poorly with skill

    DEFF Research Database (Denmark)

    Day, Dennis

    2012-01-01

    This paper offers an account of ongoing research into hearing. I offer a characterization of 'skil- led practitioners' from an Ethnomethodological perspective. The skilled practitioner in question is a generic 'hard of hearing' person. The ambition is that such a characterization, both in its...... making and its final state, may be an intrinsic part of design practices concerning the development of hearing aids....

  8. [Examination of relationship between level of hearing and written language skills in 10-14-year-old hearing impaired children].

    Science.gov (United States)

    Turğut, Nedim; Karlıdağ, Turgut; Başar, Figen; Yalçın, Şinasi; Kaygusuz, İrfan; Keleş, Erol; Birkent, Ömer Faruk

    2015-01-01

    This study aims to review the relationship between written language skills and factors which are thought to affect this skill such as mean hearing loss, duration of auditory deprivation, speech discrimination score, and pre-school education attendance and socioeconomic status of hearing impaired children who attend 4th-7th grades in primary school in inclusive environment. The study included 25 hearing impaired children (14 males, 11 females; mean age 11.4±1.4 years; range 10 to 14 years) (study group) and 20 children (9 males, 11 females; mean age 11.5±1.3 years; range 10 to 14 years) (control group) with normal hearing in the same age group and studying in the same class. Study group was separated into two subgroups as group 1a and group 1b since some of the children with hearing disability used hearing aid while some used cochlear implant. Intragroup comparisons and relational screening were performed for those who use hearing aids and cochlear implants. Intergroup comparisons were performed to evaluate the effect of the parameters on written language skills. Written expression skill level of children with hearing disability was significantly lower than their normal hearing peers (p=0.001). A significant relationship was detected between written language skills and mean hearing loss (p=0.048), duration of auditory deprivation (p=0.021), speech discrimination score (p=0.014), and preschool attendance (p=0.005), when it comes to socioeconomic status we were not able to find any significant relationship (p=0.636). It can be said that hearing loss affects written language skills negatively and hearing impaired individuals develop low-level written language skills compared to their normal hearing peers.

  9. System Level Power Optimization of Digital Audio Back End for Hearing Aids

    DEFF Research Database (Denmark)

    Pracny, Peter; Jørgensen, Ivan Harald Holger; Bruun, Erik

    2017-01-01

    This work deals with power optimization of the audio processing back end for hearing aids - the interpolation filter (IF), the sigma-delta (SD modulator and the Class D power amplifier (PA) as a whole. Specifications are derived and insight into the tradeoffs involved is used to optimize...... the interpolation filter and the SD modulator on the system level so that the switching frequency of the Class D PA - the main power consumer in the back end - is minimized. A figure-of-merit (FOM) which allows judging the power consumption of the digital part of the back end early in the design process is used...

  10. Exploring an educational assessment tool to measure registered nurses' knowledge of hearing impairment and effective communication strategies: A USA study.

    Science.gov (United States)

    Ruesch, Amy L

    2018-01-01

    Poor communication between the Registered Nurse and a hearing impaired patient can affect quality of care and health outcomes. Communication skills training programs for healthcare providers are needed to improve patient centered care. A descriptive research study, using a knowledge assessment tool developed and validated by the researcher, was conducted on 339 Registered Nurses to identify knowledge deficits to be addressed in a communication skills training program being designed. The educational tool measured the Registered Nurses' knowledge across four areas - hearing impairment, hearing aids, communication strategies, and regulations regarding access to care for a person with a hearing disability. Knowledge deficits were detected in all four areas. Using this educational assessment tool may enable nurse educators to tailor communication skills training programs to specifically address the gaps identified regarding hearing impairment and how to effectively communicate with the hearing impaired patient. Post training program, nurse educators can use the tool to evaluate effectiveness. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Hearing speech in music

    Directory of Open Access Journals (Sweden)

    Seth-Reino Ekström

    2011-01-01

    Full Text Available The masking effect of a piano composition, played at different speeds and in different octaves, on speech-perception thresholds was investigated in 15 normal-hearing and 14 moderately-hearing-impaired subjects. Running speech (just follow conversation, JFC testing and use of hearing aids increased the everyday validity of the findings. A comparison was made with standard audiometric noises [International Collegium of Rehabilitative Audiology (ICRA noise and speech spectrum-filtered noise (SPN]. All masking sounds, music or noise, were presented at the same equivalent sound level (50 dBA. The results showed a significant effect of piano performance speed and octave (P<.01. Low octave and fast tempo had the largest effect; and high octave and slow tempo, the smallest. Music had a lower masking effect than did ICRA noise with two or six speakers at normal vocal effort (P<.01 and SPN (P<.05. Subjects with hearing loss had higher masked thresholds than the normal-hearing subjects (P<.01, but there were smaller differences between masking conditions (P<.01. It is pointed out that music offers an interesting opportunity for studying masking under realistic conditions, where spectral and temporal features can be varied independently. The results have implications for composing music with vocal parts, designing acoustic environments and creating a balance between speech perception and privacy in social settings.

  12. Aparelho de amplificação sonora individual: melhora a sensação de zumbido? Hearing aid: does it reduce the sensation of tinnitus?

    Directory of Open Access Journals (Sweden)

    Robson Caique Ferreira da Silva

    2007-06-01

    Full Text Available OBJETIVO: observar se o uso da amplificação sonora além de garantir melhora na inteligibilidade de fala pode proporcionar alívio na sensação de zumbido. MÉTODOS: participaram do presente estudo 21 indivíduos, usuários de aparelho de amplificação sonora individual (AASI que referiam sensação de zumbido, além da perda auditiva sensorioneural, sendo 13 (61,9% indivíduos do sexo feminino e oito (38,1% do sexo masculino. A idade dos participantes variou entre 35 a 88 anos, com idade média de 61 anos. Para a avaliação dos participantes foi utilizado um questionário específico. Os dados foram analisados por meio de análise estatística descritiva e para tanto foram utilizados os testes não paramétricos: qui-quadrado e Kruskal-Wallis H. RESULTADOS: Entre os 21 participantes, 17 (80,9% apresentaram melhora do zumbido, enquanto quatro (19,1% referiram que o aparelho de amplificação não gerou nenhum efeito sobre o sintoma apresentado. CONCLUSÃO: este estudo verificou que a utilização do AASI reduziu imediatamente a sensação de zumbido apresentada na população estudada.PURPOSE: to observe if the use of hearing aid may provide relief in tinnitus sensation besides guarantying the improvement of speech intelligibility. METHODS: a sample was made up by 21 hearing aid users and a specific questionnaire was used for the evaluation of the participants. The ages ranged from 35 to 88-year old, with an average of 61-year old. The tinnitus sensation was mentioned by 13 (61.9% female beings and eight (38.1% male beings beyond sensory neural hearing loss. The results were obtained through a descriptive statistical analysis, and furthermore, non-parametric tests were used, such as chi-square and Kruskal-Wallis H. RESULTS: among the participants 17 (80.9% showed recovery from tinnitus, while four (19.1% said that the hearing aid device did not cause any effect on the evidenced symptoms. CONCLUSION: this study found out that the usage of

  13. Sound Classification in Hearing Aids Inspired by Auditory Scene Analysis

    Science.gov (United States)

    Büchler, Michael; Allegro, Silvia; Launer, Stefan; Dillier, Norbert

    2005-12-01

    A sound classification system for the automatic recognition of the acoustic environment in a hearing aid is discussed. The system distinguishes the four sound classes "clean speech," "speech in noise," "noise," and "music." A number of features that are inspired by auditory scene analysis are extracted from the sound signal. These features describe amplitude modulations, spectral profile, harmonicity, amplitude onsets, and rhythm. They are evaluated together with different pattern classifiers. Simple classifiers, such as rule-based and minimum-distance classifiers, are compared with more complex approaches, such as Bayes classifier, neural network, and hidden Markov model. Sounds from a large database are employed for both training and testing of the system. The achieved recognition rates are very high except for the class "speech in noise." Problems arise in the classification of compressed pop music, strongly reverberated speech, and tonal or fluctuating noises.

  14. Comparing response options for the International Outcome Inventory for Hearing Aids (IOI-HA) and for Alternative Interventions (IOI-AI) daily-use items.

    Science.gov (United States)

    Laplante-Lévesque, Ariane; Hickson, Louise; Worrall, Linda

    2012-10-01

    This study investigated how clients quantify use of hearing rehabilitation. Comparisons focused on the daily-use item of the International Outcome Inventory for Hearing Aids (IOI-HA), and for Alternative Interventions (IOI-AI). Adults with hearing impairment completed the original versions of the IOI-HA and the IOI-AI daily-use item which has five numerical response options (e.g. 1-4 hours/day) and a modified version with five word response options (e.g. 'Sometimes'). Respondents completed both IOI versions immediately after intervention completion and three months later. In total, 64 people who had obtained hearing aids completed both IOI-HA versions and 27 people who had participated in communication programs completed both IOI-AI versions. Participants reported higher scores on the modified (word) daily-use item than on the original (number) daily-use item. Participants who completed the IOI-AI did so significantly more than participants who completed the IOI-HA. This was true both after intervention completion and three months later. This study showed that comparisons between IOI-HA and IOI-AI daily-use item scores should be made with caution. Word daily-use response options are recommended for the IOI-AI (i.e. Never; Rarely; Sometimes; Often; and Almost always).

  15. Differences and similarities in early vocabulary development between children with hearing aids and children with cochlear implant enrolled in 3-year auditory verbal intervention.

    Science.gov (United States)

    Percy-Smith, Lone; Hallstrøm, Maria; Josvassen, Jane Lignel; Mikkelsen, Jeanette Hølledig; Nissen, Lena; Dieleman, Eveline; Cayé-Thomasen, Per

    2018-05-01

    The overall objective of this study was to evaluate the implementation of a Nordic Auditory Verbal (AV) intervention for children with all degrees and types of hearing impairment (HI) using all kinds of hearing technology. A first specific objective was to identify differences and similarities in early vocabulary development between children with cochlear implant (CI) compared with children with hearing aids (HAs)/Bone anchored hearing aids (Bahs) enrolled in a 3-year AVprogram, and to compare the group of children with HI to a control group of children with normal hearing (NH). A second specific objective was to study universal neonatal hearing screening (UNHS) using the 1-3-6 Early Hearing Detection and Intervention (EHDI) guidelines. Effect of AV intervention for children with HI using different hearing technology is not thoroughly studied. It is relevant to question, whether children with mild to moderate HI encounter the same intensive need for AV intervention as children with congenital deafness. A longitudinal and comparative study design was used involving two cohorts of children, i.e. 36 children with CI and 19 children with HA/Bahs. The children were the first in Denmark to receive a 3-year AV intervention by formally trained AV-practitioners. Children were tested annually with standardized speech and language tests, i.e. Peabody Picture Vocabulary test, Reynell test and a Danish test for active vocabulary, Viborgmaterialet. Categorical variables were compared using Fischer's exact test and continuous variables were compared using Wilcoxon-Mann-Whitney test, as data was not normally distributed. Median age of diagnosis was 6 months and median age at intervention was 13 and 12 months respectively. There was no statistically significant difference between the two groups in terms of scores according to age equivalency for the three tests. However, there was a significant difference between children with HI regardless of hearing technology and children with

  16. Maximum likelihood approach to “informed” Sound Source Localization for Hearing Aid applications

    DEFF Research Database (Denmark)

    Farmani, Mojtaba; Pedersen, Michael Syskind; Tan, Zheng-Hua

    2015-01-01

    Most state-of-the-art Sound Source Localization (SSL) algorithms have been proposed for applications which are "uninformed'' about the target sound content; however, utilizing a wireless microphone worn by a target talker, enables recent Hearing Aid Systems (HASs) to access to an almost noise......-free sound signal of the target talker at the HAS via the wireless connection. Therefore, in this paper, we propose a maximum likelihood (ML) approach, which we call MLSSL, to estimate the Direction of Arrival (DoA) of the target signal given access to the target signal content. Compared with other "informed...

  17. Recent concepts and challenges in hearing research

    DEFF Research Database (Denmark)

    Dau, Torsten

    In everyday life, the speech we listen to is often mixed with many other sound sources as well as reverberation. In such a situation, normal-hearing listeners are able to effortlessly segregate a single voice out of the background, which is commonly known as the 'cocktail party effect'. Conversely......, hearing-impaired people have great difficulty understanding speech when more than one person is talking, even when reduced audibility has been fully compensated for by a hearing aid. As with the hearing impaired, the performance of automatic speech recognition systems deteriorates dramatically...... with additional sound sources. The reasons for these difficulties are not well understood. Only by obtaining a clearer understanding of the auditory system’s coding strategies will it be possible to design intelligent compensation algorithms for hearing devices. This presentation highlights recent concepts...

  18. Hearing speech in music.

    Science.gov (United States)

    Ekström, Seth-Reino; Borg, Erik

    2011-01-01

    The masking effect of a piano composition, played at different speeds and in different octaves, on speech-perception thresholds was investigated in 15 normal-hearing and 14 moderately-hearing-impaired subjects. Running speech (just follow conversation, JFC) testing and use of hearing aids increased the everyday validity of the findings. A comparison was made with standard audiometric noises [International Collegium of Rehabilitative Audiology (ICRA) noise and speech spectrum-filtered noise (SPN)]. All masking sounds, music or noise, were presented at the same equivalent sound level (50 dBA). The results showed a significant effect of piano performance speed and octave (Ptempo had the largest effect; and high octave and slow tempo, the smallest. Music had a lower masking effect than did ICRA noise with two or six speakers at normal vocal effort (Pmusic offers an interesting opportunity for studying masking under realistic conditions, where spectral and temporal features can be varied independently. The results have implications for composing music with vocal parts, designing acoustic environments and creating a balance between speech perception and privacy in social settings.

  19. Visual Cues Contribute Differentially to Audiovisual Perception of Consonants and Vowels in Improving Recognition and Reducing Cognitive Demands in Listeners With Hearing Impairment Using Hearing Aids.

    Science.gov (United States)

    Moradi, Shahram; Lidestam, Björn; Danielsson, Henrik; Ng, Elaine Hoi Ning; Rönnberg, Jerker

    2017-09-18

    We sought to examine the contribution of visual cues in audiovisual identification of consonants and vowels-in terms of isolation points (the shortest time required for correct identification of a speech stimulus), accuracy, and cognitive demands-in listeners with hearing impairment using hearing aids. The study comprised 199 participants with hearing impairment (mean age = 61.1 years) with bilateral, symmetrical, mild-to-severe sensorineural hearing loss. Gated Swedish consonants and vowels were presented aurally and audiovisually to participants. Linear amplification was adjusted for each participant to assure audibility. The reading span test was used to measure participants' working memory capacity. Audiovisual presentation resulted in shortened isolation points and improved accuracy for consonants and vowels relative to auditory-only presentation. This benefit was more evident for consonants than vowels. In addition, correlations and subsequent analyses revealed that listeners with higher scores on the reading span test identified both consonants and vowels earlier in auditory-only presentation, but only vowels (not consonants) in audiovisual presentation. Consonants and vowels differed in terms of the benefits afforded from their associative visual cues, as indicated by the degree of audiovisual benefit and reduction in cognitive demands linked to the identification of consonants and vowels presented audiovisually.

  20. Percepção de idosos sobre o uso de AASI concedido pelo Sistema Único de Saúde Elderly perception on the use of hearing aids given by the health ystem (SUS

    Directory of Open Access Journals (Sweden)

    Indiara de Mesquita Fialho

    2009-06-01

    : Difficulties of communication without hearing aids; The Access to the hearing aids and The Adaptation Process; The impact of hearing aids use in communication. RESULTS: communication difficulty is higher in situations where there are many people talking; the difficulty is not in listening but in understanding; they show concern about distinguishing what they feel being deaf. Most subjects did not have previous hearing aids adaptation due to financial difficulties and revealed that their access to hearing aids was through implementation of Hearing Health Care Service. The difficulties concerning the adaptation process were: changing the perception of their own voice, difficulty in understanding the communication in noisy environment and on the phone. They reported the benefits of hearing aids use in communication with relatives and strangers. CONCLUSION: the monitoring process importance is highlighted so that the difficulties for adjustment can be effectively detected and minimized. Such being the case, the patient gets the benefit and satisfaction from the treatment.

  1. Hearing aids with no batteries

    DEFF Research Database (Denmark)

    Day, Dennis

    2011-01-01

    In this paper I wish to offer a characterization of 'skilled practitioners' from an Ethnomethodological perspective. The skilled practitioner in question is a generic 'hard of hearing' person. The ambition is that such a characterization, both in its making and its final state, may be an intrinsi...

  2. Special needs children with speech and hearing difficulties: prevalence and unmet needs.

    Science.gov (United States)

    Kenney, Mary Kay; Kogan, Michael D

    2011-01-01

    The purpose of this study was to establish prevalences and sociodemographic characteristics associated with parent-reported speech and hearing difficulties among children with special health care needs (CSHCN); determine unmet needs for therapy, hearing aids, and communication devices; and examine the association between unmet needs and resources such as health insurance, early intervention/special education, and a medical home. Data were analyzed for 300,910 children without special health care needs and 40,723 CSHCN from the 2005-2006 National Survey of Children with Special Health Care Needs. Prevalence, sociodemographic characteristics, and unmet needs for 7132 CSHCN with speech difficulties and 1982 CSHCN with hearing difficulties were assessed. Logistic regression was used to determine the associations between unmet needs for therapy or hearing/communication devices and resources for addressing needs for therapy, hearing, and communication aids. The parent-reported prevalence of speech difficulty among CSHCN in the general population was 2.9% and approximately 20% among all CSHCN, in contrast to the lower prevalence of hearing difficulty (0.7% and 5%, respectively). Relative unmet need was greatest for communication devices and least for hearing aids. The strongest association with reducing unmet needs was having a medical home, and the most significant aspect of medical home was having effective care coordination. Having a medical home is significantly associated with fewer unmet needs for therapy and hearing/communication devices among CSHCN with speech and hearing difficulties. Care coordination may constitute an important factor that allows the primary care provider to link with services that CSHCN with communication problems require. Published by Elsevier Inc.

  3. Development of Bone-Conducted Ultrasonic Hearing Aid for the Profoundly Deaf: Assessments of the Modulation Type with Regard to Intelligibility and Sound Quality

    Science.gov (United States)

    Nakagawa, Seiji; Fujiyuki, Chika; Kagomiya, Takayuki

    2012-07-01

    Bone-conducted ultrasound (BCU) is perceived even by the profoundly sensorineural deaf. A novel hearing aid using the perception of amplitude-modulated BCU (BCU hearing aid: BCUHA) has been developed; however, further improvements are needed, especially in terms of articulation and sound quality. In this study, the intelligibility and sound quality of BCU speech with several types of amplitude modulation [double-sideband with transmitted carrier (DSB-TC), double-sideband with suppressed carrier (DSB-SC), and transposed modulation] were evaluated. The results showed that DSB-TC and transposed speech were more intelligible than DSB-SC speech, and transposed speech was closer than the other types of BCU speech to air-conducted speech in terms of sound quality. These results provide useful information for further development of the BCUHA.

  4. Active noise cancellation in hearing devices

    DEFF Research Database (Denmark)

    2013-01-01

    Disclosed is a hearing device system comprising at least one hearing aid circuitry and at least one active noise cancellation unit, the at least one hearing aid circuitry comprises at least one input transducer adapted to convert a first audio signal to an electric audio signal; a signal processor...... connected to the at least one input transducer and adapted to process said electric audio signal by at least partially correcting for a hearing loss of a user; an output transducer adapted to generate from at least said processed electric audio signal a sound pressure in an ear canal of the user, whereby...... the generated sound pressure is at least partially corrected for the hearing loss of the user; ; the at least one active noise cancellation unit being adapted to provide an active noise cancellation signal adapted to perform active noise cancellation of an acoustical signal entering the ear canal in addition...

  5. Curing hearing loss: Patient expectations, health care practitioners, and basic science.

    Science.gov (United States)

    Oshima, Kazuo; Suchert, Steffen; Blevins, Nikolas H; Heller, Stefan

    2010-01-01

    Millions of patients are debilitated by hearing loss, mainly caused by degeneration of sensory hair cells in the cochlea. The underlying reasons for hair cell loss are highly diverse, ranging from genetic disposition, drug side effects, traumatic noise exposure, to the effects of aging. Whereas modern hearing aids offer some relief of the symptoms of mild hearing loss, the only viable option for patients suffering from profound hearing loss is the cochlear implant. Despite their successes, hearing aids and cochlear implants are not perfect. Particularly frequency discrimination and performance in noisy environments and general efficacy of the devises vary among individual patients. The advent of regenerative medicine, the publicity of stem cells and gene therapy, and recent scientific achievements in inner ear cell regeneration have generated an emerging spirit of optimism among scientists, health care practitioners, and patients. In this review, we place the different points of view of these three groups in perspective with the goal of providing an assessment of patient expectations, health care reality, and potential future treatment options for hearing disorders. (1) Readers will be encouraged to put themselves in the position of a hearing impaired patient or family member of a hearing impaired person. (2) Readers will be able to explain why diagnosis of the underlying pathology of hearing loss is difficult. (3) Readers will be able to list the main directions of current research aimed to cure hearing loss. (4) Readers will be able to understand the different viewpoints of patients and their relatives, health care providers, and scientists with respect to finding novel treatments for hearing loss. Copyright 2010 Elsevier Inc. All rights reserved.

  6. Hearing Loss Signals Need for Diagnosis

    Science.gov (United States)

    ... Products For Consumers Home For Consumers Consumer Updates Hearing Loss Signals Need for Diagnosis Share Tweet Linkedin ... you’re talking loudly? Thinking about ordering a hearing aid or sound amplifier from a magazine or ...

  7. What Factors Are Associated with Autonomous and Controlled Motivation for Hearing Help-Seekers?

    Science.gov (United States)

    Ridgway, Jason; Hickson, Louise; Lind, Christopher

    Hearing impairment is prevalent in older adults. Motivation is important in people's choice to seek help for their hearing and whether to adopt or not adopt hearing aids. To investigate associations between sociodemographic and audiometric characteristics and autonomous and controlled motivation among a sample of hearing help-seekers. A quantitative approach was taken for this cross-sectional cohort study. A total of 253 adult first-time hearing help-seekers were recruited to the study. Participants provided sociodemographic information and completed questionnaires adapted from self-determination theory that measured autonomous motivation (motivation that originates from within the self and is aligned with personal values and beliefs) and controlled motivation (motivation that stems from external pressures such as rewards or punishment, or conflicted inner feelings such as guilt or shame). Participants with higher autonomous motivation scores were younger, wanted hearing aids more, and reported greater hearing difficulty in everyday life than those with lower scores. Participants with higher controlled motivation scores were more often referred to the service by others and wanted hearing aids more than those with lower controlled motivation scores. Controlled motivation scores were not associated with perceptions of hearing difficulty in everyday life. Relationships among motivation and sociodemographic factors highlight the importance of characterizing autonomous and controlled motivation in first-time hearing help-seekers. Attention to personal characteristics in order to understand motivational processes involved in rehabilitation decisions such as hearing aid adoption may aid in consultations. American Academy of Audiology

  8. Inter-trial coherence as a marker of cortical phase synchrony in children with sensorineural hearing loss and auditory neuropathy spectrum disorder fitted with hearing aids and cochlear implants

    Science.gov (United States)

    Nash-Kille, Amy; Sharma, Anu

    2014-01-01

    Objective Although brainstem dys-synchrony is a hallmark of children with auditory neuropathy spectrum disorder (ANSD), little is known about how the lack of neural synchrony manifests at more central levels. We used time-frequency single-trial EEG analyses (i.e., inter-trial coherence; ITC), to examine cortical phase synchrony in children with normal hearing (NH), sensorineural hearing loss (SNHL) and ANSD. Methods Single trial time-frequency analyses were performed on cortical auditory evoked responses from 41 NH children, 91 children with ANSD and 50 children with SNHL. The latter two groups included children who received intervention via hearing aids and cochlear implants. ITC measures were compared between groups as a function of hearing loss, intervention type, and cortical maturational status. Results In children with SNHL, ITC decreased as severity of hearing loss increased. Children with ANSD revealed lower levels of ITC relative to children with NH or SNHL, regardless of intervention. Children with ANSD who received cochlear implants showed significant improvements in ITC with increasing experience with their implants. Conclusions Cortical phase coherence is significantly reduced as a result of both severe-to-profound SNHL and ANSD. Significance ITC provides a window into the brain oscillations underlying the averaged cortical auditory evoked response. Our results provide a first description of deficits in cortical phase synchrony in children with SNHL and ANSD. PMID:24360131

  9. Apps for Hearing Science and Care.

    Science.gov (United States)

    Paglialonga, Alessia; Tognola, Gabriella; Pinciroli, Francesco

    2015-09-01

    Our research aims at the identification and assessment of applications (referred to as apps) in the hearing health care domain. This research forum article presents an overview of the current availability, affordability, and variety of hearing-related apps. The available apps were reviewed by searching on the leading platforms (iOS, Android, Windows Phone stores) using the keywords hearing, audiology, audio, auditory, speech, language, tinnitus, hearing loss, hearing aid, hearing sys tem, cochlear implant, implantable device, auditory training, hearing rehabilitation, and assistive technology/tool/device. O n the bas is of the offered services, apps were classified into 4 application domains: (a) screening and assessment, (b) intervention and rehabilitation, (c) education and information, and (d) assistive tools. A large variety of apps are available in the hearing health care domain. These cover a wide range of services for people with hearing or communication problems as well as for hearing professionals, families, or informal caregivers. This evolution can potentially bring along considerable advantages and improved outcomes in the field of hearing health care. Nevertheless, potential risks and threats (e.g., safety, quality, effectiveness, privacy, and regulation) should not be overlooked. Significant research—particularly in terms of assessment and guidance—is still needed for the informed, aware, and safe adoption of hearing-related apps by patients and professionals.

  10. Impact of Hearing Aid Technology on Outcomes in Daily Life II: Speech Understanding and Listening Effort.

    Science.gov (United States)

    Johnson, Jani A; Xu, Jingjing; Cox, Robyn M

    2016-01-01

    Modern hearing aid (HA) devices include a collection of acoustic signal-processing features designed to improve listening outcomes in a variety of daily auditory environments. Manufacturers market these features at successive levels of technological sophistication. The features included in costlier premium hearing devices are designed to result in further improvements to daily listening outcomes compared with the features included in basic hearing devices. However, independent research has not substantiated such improvements. This research was designed to explore differences in speech-understanding and listening-effort outcomes for older adults using premium-feature and basic-feature HAs in their daily lives. For this participant-blinded, repeated, crossover trial 45 older adults (mean age 70.3 years) with mild-to-moderate sensorineural hearing loss wore each of four pairs of bilaterally fitted HAs for 1 month. HAs were premium- and basic-feature devices from two major brands. After each 1-month trial, participants' speech-understanding and listening-effort outcomes were evaluated in the laboratory and in daily life. Three types of speech-understanding and listening-effort data were collected: measures of laboratory performance, responses to standardized self-report questionnaires, and participant diary entries about daily communication. The only statistically significant superiority for the premium-feature HAs occurred for listening effort in the loud laboratory condition and was demonstrated for only one of the tested brands. The predominant complaint of older adults with mild-to-moderate hearing impairment is difficulty understanding speech in various settings. The combined results of all the outcome measures used in this research suggest that, when fitted using scientifically based practices, both premium- and basic-feature HAs are capable of providing considerable, but essentially equivalent, improvements to speech understanding and listening effort in daily

  11. Psycholinguistic abilities in cochlear implant and hearing impaired children

    OpenAIRE

    Hassan, Hatem Ezzeldin; Eldin, Sally Taher Kheir; Al Kasaby, Rasha Mohamed

    2014-01-01

    Background: Many congenitally sensorineural hearing loss (SNHL) children and cochlear implant (CI) recipients develop near-normal language skills. However, there is a wide variation in individual outcomes following cochlear implantation, or using hearing aids. Some CI recipients or Hearing aids users never develop useable speech and oral language skills. The causes of this enormous variation in outcomes are only partly understood at the present time. So, the aim of this study was to assess th...

  12. Adult hearing screening: the Cyprus Pilot Program

    Directory of Open Access Journals (Sweden)

    C. Thodi

    2011-03-01

    Full Text Available Hearing loss is the third most common condition affecting adults over 65 (Cruickshanks et al., 1998. It can affect quality of life, limiting the ability to communicate efficiently, and leading to isolation, psychological strain, and functional decline (LaForge, Spector, Sternberg, 1992; Yueh, Shapiro, MacLean, Shekelle, 2003. Communication limitations impinge on the person directly, as well as the family, friends, and social circle. Reports on hearing loss among adults indicate that less than 25% of people who can benefit from amplification are actually using hearing aids, and that people diagnosed with a hearing loss delay seeking amplification by about seven years (Kochkin, 1997. Often, family members are the driving force behind a person with a hearing loss who decides to seek help. Adult hearing screening programs might have a positive effect on raising public awareness on hearing loss and its implications, and shortening delay time for intervention. There is no routine hearing screening for the adult population in Cyprus. The health system provides hearing tests for beneficiaries upon physician recommendation or self-referral. The Cyprus pilot adult hearing screening program (ΑΠΑΣ- EVERYONE- Greek acronym for Screening- Intervention-Hearing-Participation to Life screened hearing in retired adults.

  13. Attitude and help-seeking for hearing impairment

    NARCIS (Netherlands)

    vandenBrink, RHS; Wit, HP; Kempen, GIJM; vanHeuvelen, MJG

    1996-01-01

    The aim of the present study was to investigate help-seeking for hearing impairment in the elderly, and to compare groups showing dissimilar help-seeking on their attitude toward hearing loss and hearing aids. Attitude factors were based on a revised version of the Health Belief Model, and included

  14. Efeito da estimulação acústica nas habilidades do processamento temporal em idosos antes e após a protetização auditiva Acoustic stimulation effect on temporal processing skills in elderly subjects before and after hearing aid fitting

    Directory of Open Access Journals (Sweden)

    Maria Madalena Canina Pinheiro

    2012-08-01

    and of discrimination of the duration pattern in relation to when they were only potential users. CONCLUSION: There was a deterioration in temporal processing skills, regardless of hearing loss degrees. Thus, the effect of acoustic stimulation by the use of a hearing aid improved resolution and temporal ordering.

  15. Combined Electric and Acoustic Stimulation With Hearing Preservation: Effect of Cochlear Implant Low-Frequency Cutoff on Speech Understanding and Perceived Listening Difficulty.

    Science.gov (United States)

    Gifford, René H; Davis, Timothy J; Sunderhaus, Linsey W; Menapace, Christine; Buck, Barbara; Crosson, Jillian; O'Neill, Lori; Beiter, Anne; Segel, Phil

    The primary objective of this study was to assess the effect of electric and acoustic overlap for speech understanding in typical listening conditions using semidiffuse noise. This study used a within-subjects, repeated measures design including 11 experienced adult implant recipients (13 ears) with functional residual hearing in the implanted and nonimplanted ear. The aided acoustic bandwidth was fixed and the low-frequency cutoff for the cochlear implant (CI) was varied systematically. Assessments were completed in the R-SPACE sound-simulation system which includes a semidiffuse restaurant noise originating from eight loudspeakers placed circumferentially about the subject's head. AzBio sentences were presented at 67 dBA with signal to noise ratio varying between +10 and 0 dB determined individually to yield approximately 50 to 60% correct for the CI-alone condition with full CI bandwidth. Listening conditions for all subjects included CI alone, bimodal (CI + contralateral hearing aid), and bilateral-aided electric and acoustic stimulation (EAS; CI + bilateral hearing aid). Low-frequency cutoffs both below and above the original "clinical software recommendation" frequency were tested for all patients, in all conditions. Subjects estimated listening difficulty for all conditions using listener ratings based on a visual analog scale. Three primary findings were that (1) there was statistically significant benefit of preserved acoustic hearing in the implanted ear for most overlap conditions, (2) the default clinical software recommendation rarely yielded the highest level of speech recognition (1 of 13 ears), and (3) greater EAS overlap than that provided by the clinical recommendation yielded significant improvements in speech understanding. For standard-electrode CI recipients with preserved hearing, spectral overlap of acoustic and electric stimuli yielded significantly better speech understanding and less listening effort in a laboratory-based, restaurant

  16. Dynamic-range reduction by peak clipping or compression and its effects on phoneme perception in hearing-impaired listeners

    NARCIS (Netherlands)

    Dreschler, W. A.

    1988-01-01

    In this study, differences between dynamic-range reduction by peak clipping and single-channel compression for phoneme perception through conventional hearing aids have been investigated. The results from 16 hearing-impaired listeners show that compression limiting yields significantly better

  17. Sound quality measures for speech in noise through a commercial hearing aid implementing digital noise reduction.

    Science.gov (United States)

    Ricketts, Todd A; Hornsby, Benjamin W Y

    2005-05-01

    This brief report discusses the affect of digital noise reduction (DNR) processing on aided speech recognition and sound quality measures in 14 adults fitted with a commercial hearing aid. Measures of speech recognition and sound quality were obtained in two different speech-in-noise conditions (71 dBA speech, +6 dB SNR and 75 dBA speech, +1 dB SNR). The results revealed that the presence or absence of DNR processing did not impact speech recognition in noise (either positively or negatively). Paired comparisons of sound quality for the same speech in noise signals, however, revealed a strong preference for DNR processing. These data suggest that at least one implementation of DNR processing is capable of providing improved sound quality, for speech in noise, in the absence of improved speech recognition.

  18. Rotina de procedimentos utilizados na seleção e adaptação de aparelhos de amplificação sonora individual em centros auditivos na cidade de Porto Alegre, Brasil - RS Routine of procedures used on the selection and adaptation of hearing aids at hearing centers in the city of Porto Alegre, Brazil - RS

    Directory of Open Access Journals (Sweden)

    Mariele Boscaini Zandavalli

    2009-01-01

    79 years, the kind of adaptation was monoaural, and most Hearing Centers make usage orientation, post-acquisition follow-up and prior home experience. CONCLUSION: the results have shown that there were no divergences among the examined Hearing Centers, however some procedures would have significant importance for the selection process of hearing aids, as they would contribute for the success of an effective hearing aid fitting.

  19. Hearing Evaluation in Children (For Parents)

    Science.gov (United States)

    ... Loss? Going to a Speech Therapist Can Loud Music Hurt My Ears? Going to the Audiologist Hearing Impairment Speech Problems Hearing Aids Earbuds View more About Us Contact Us Partners Editorial Policy Permissions Guidelines Privacy Policy & Terms of Use Notice ...

  20. Online Personalization of Hearing Instruments

    Directory of Open Access Journals (Sweden)

    Bert de Vries

    2008-09-01

    Full Text Available Online personalization of hearing instruments refers to learning preferred tuning parameter values from user feedback through a control wheel (or remote control, during normal operation of the hearing aid. We perform hearing aid parameter steering by applying a linear map from acoustic features to tuning parameters. We formulate personalization of the steering parameters as the maximization of an expected utility function. A sparse Bayesian approach is then investigated for its suitability to find efficient feature representations. The feasibility of our approach is demonstrated in an application to online personalization of a noise reduction algorithm. A patient trial indicates that the acoustic features chosen for learning noise control are meaningful, that environmental steering of noise reduction makes sense, and that our personalization algorithm learns proper values for tuning parameters.

  1. Predicting consonant recognition and confusions in normal-hearing listeners

    DEFF Research Database (Denmark)

    Zaar, Johannes; Dau, Torsten

    2017-01-01

    , Kollmeier, and Kohlrausch [(1997). J. Acoust. Soc. Am. 102, 2892–2905]. The model was evaluated based on the extensive consonant perception data set provided by Zaar and Dau [(2015). J. Acoust. Soc. Am. 138, 1253–1267], which was obtained with normal-hearing listeners using 15 consonant-vowel combinations...... confusion groups. The large predictive power of the proposed model suggests that adaptive processes in the auditory preprocessing in combination with a cross-correlation based template-matching back end can account for some of the processes underlying consonant perception in normal-hearing listeners....... The proposed model may provide a valuable framework, e.g., for investigating the effects of hearing impairment and hearing-aid signal processing on phoneme recognition....

  2. Externalization versus Internalization of Sound in Normal-hearing and Hearing-impaired Listeners

    DEFF Research Database (Denmark)

    Ohl, Björn; Laugesen, Søren; Buchholz, Jörg

    2010-01-01

    The externalization of sound, i. e. the perception of auditory events as being located outside of the head, is a natural phenomenon for normalhearing listeners, when perceiving sound coming from a distant physical sound source. It is potentially useful for hearing in background noise......, but the relevant cues might be distorted by a hearing impairment and also by the processing of the incoming sound through hearing aids. In this project, two intuitive tests in natural real-life surroundings were developed, which capture the limits of the perception of externalization. For this purpose...

  3. French-Canadian translation and validation of four questionnaires assessing hearing impairment and handicap.

    Science.gov (United States)

    Vincent, Claude; Gagné, Jean-Pierre; Leroux, Tony; Clothier, Audrey; Larivière, Marianne; Dumont, Frédéric S; Gendron, Martine

    2017-04-01

    Questionnaires evaluating hearing impairment are available in English but there is a need for French standardised questionnaires for researchers as well as for audiologists and other clinicians. The objective of this study is to describe the translation and validation of four questionnaires that assess different aspects of hearing impairment and handicap among elders with hearing loss, by comparing the main score and psychometric evaluation of original and French-Canadian (FC) versions of the World Health Organization Disability Assessment Scale II (WHO-DAS II), the Screening Test for Hearing Problems (STHP), the Abbreviated Profile of Hearing Aid Benefit (APHAB) and the Measure of Audiologic Rehabilitation Self-Efficacy for Hearing Aids (MARS-HA). Vallerand method: translation and back-translation by two translators, revision by a committee of experts and pre-tested with five bilingual older participants. Participants (n = 29) were 65 years of age or older including 21 with hearing aids. The psychometric properties (internal consistency, temporal stability after four weeks) indicate good reliability for most of the translated questionnaires and their subscales, especially the WHO-DAS II. The translations in FC of two hearing loss and two hearing aid questionnaires were validated. It is recommended to pursue the demonstration for temporal stability for the STHP.

  4. Everyday trajectories of hearing correction

    DEFF Research Database (Denmark)

    Lykke Hindhede, Anette

    2010-01-01

    wearers in order to rehabilitate them back to ‘normal'. However, within audiological research, noncompliance has attracted much attention as investigations have shown that more than 20 percent of hearing aids are very seldom, if ever, in use and 19 percent are used only occasionally. As shown in the paper...... are complex and epistemologically contested and can help explain why noncompliance is dominant when it comes to hearing rehabilitation for hearing impaired adults....

  5. Qualidade de vida em idosos antes e após a adaptação do AASI Quality of life in elderly adults before and after hearing aid fitting

    Directory of Open Access Journals (Sweden)

    Maria Fernanda Capoani Garcia Mondelli

    2012-06-01

    ; and after the effective use of a sound amplification device for a period of three months they answered it again. The WHOQOL - Bref consists of 26 questions, two general quality-of-life questions and 24 associated with four aspects: physical, psychological, environmental and social relations. RESULTS: There was a significant improvement in quality of life in general, as far as leisure activities were concerned, there were no major changes regarding the frequency of negative feelings; even after the hearing aid fitting, the patients continue to have such feelings. CONCLUSION: The use of hearing aids favored the overall quality of life of the individuals evaluated.

  6. Speech perception in noise in unilateral hearing loss

    OpenAIRE

    Mondelli, Maria Fernanda Capoani Garcia; dos Santos, Marina de Marchi; José, Maria Renata

    2016-01-01

    ABSTRACT INTRODUCTION: Unilateral hearing loss is characterized by a decrease of hearing in one ear only. In the presence of ambient noise, individuals with unilateral hearing loss are faced with greater difficulties understanding speech than normal listeners. OBJECTIVE: To evaluate the speech perception of individuals with unilateral hearing loss in speech perception with and without competitive noise, before and after the hearing aid fitting process. METHODS: The study included 30 adu...

  7. Design for redundancy in a participatory action that helps user calibrating hearing devices

    DEFF Research Database (Denmark)

    Simeone, Luca

    2018-01-01

    and hearing aid simulator) and (b) adopting these technologies to create videogames that can be used by people with hearing aids to fine-tune their hearing devices. The high number of stakeholders involved in the project and their differences (in terms of needs, wants and agendas) motivated a design approach...

  8. Real-life efficacy and reliability of training a hearing aid.

    Science.gov (United States)

    Keidser, Gitte; Alamudi, Karima

    2013-09-01

    Commercial trainable hearing aids (HA) (i.e., devices that for a period are adjusted by the user in different acoustic environments and that subsequently with changing environments automatically adapt to the user's preferred settings), are readily available; however, little information exists about the efficacy of training a HA. The purpose of this study was to investigate the efficacy and reliability of training a HA in everyday environments. The participants were 26 hearing-impaired volunteers with a median age of 79 years and an average pure-tone average of 53 dB HL. Test devices were commercial, multimemory, prototype devices that enabled training of the compression characteristics in four frequency bands and in six sound classes. Participants wore the National Acoustic Laboratories nonlinear fitting procedure version 2 prescription for 3 weeks and trained the devices from the prescribed response for 3 weeks, before comparing their trained response with the prescription for 2 weeks. The devices were reset to the prescription, and 19 participants repeated the training and comparison trials. During the comparison trial, participants made daily diary ratings of their satisfaction with the programs, and a structured interview was completed at the end of the comparison trial. The participants displayed different needs for changing the prescription, with more daily adjustments leading to training across more sound classes. Unreliable observations were obtained from 8 participants after each of the test and retest comparison trials. Of the 10 participants who made sufficient changes to the prescription during the first trial, 80% preferred their trained response. The 8 "low trainers" reported no preference, and also reported lower overall satisfaction with the device. Fewer adjustments were made during the repeat trial, resulting in less training. Significant correlations between trained variations were seen for 63% of 19 participants. Of the 10 participants who

  9. O autoconceito do adolescente deficiente auditivo e sua relação com o uso do aparelho de amplificação sonora individual Hearing impaired adolescents' self-concept and their relations to hearing aids

    Directory of Open Access Journals (Sweden)

    Ana Paula Zugliani

    2007-04-01

    Full Text Available Para o adolescente com deficiência auditiva, o processo de formação da identidade tem nuances próprias. Além do conflito específico da fase, ele tem que formar sua identidade como pessoa que possui uma perda auditiva e que necessita usar aparelho de amplificação sonora individual (AASI. Considerando que os fatores que influenciam o uso desse recurso são inúmeros, este trabalho teve por objetivo verificar a relação do autoconceito do adolescente deficiente auditivo (DA com o uso do AASI, a partir da percepção do próprio adolescente e de seus pais. A Escala de Autoconceito - EACIJ - e questionários foram aplicados a 30 adolescentes deficientes auditivos, com idades de 12 a 16 anos, em tratamento no Centro de Distúrbios da Audição, Linguagem e Visão (CEDALVI do HRAC/USP e a seus pais. Os resultados mostraram que a maioria dos adolescentes estudados faz uso efetivo de seu AASI e tem autoconceito positivo. Concluiu-se que o uso constante desse recurso está associado às boas condições do autoconceito e ao suporte psicossocial da equipe multi / interdisciplinar.For adolescents who have hearing impairment, the identity formation process has its own subtleties. Besides the conflicts which are a part of being a teenager, he/she has to form his/her identity as someone who has a hearing loss and needs a hearing aid. Taking into account the countless factors influencing the use of this resource, this study aimed to undercover the relations between self-concepts of deaf adolescents to the use of hearing aid, looking at the adolescents' own perceptions and those of his parents. The Self-concept Scale - EACIJ - and questionnaires were applied to 30 hearing impaired adolescents, aged 12-16 years, undergoing treatment at the Centro de Distúrbios da Audição, Linguagem e Visão (CEDALVI, a service center within the HRAC/USP, and to their parents. The results showed that most of the subjects involved in the study actually use their hearing

  10. Effects of auditory training in individuals with high-frequency hearing loss

    Directory of Open Access Journals (Sweden)

    Renata Beatriz Fernandes Santos

    2014-01-01

    Full Text Available OBJECTIVE: To determine the effects of a formal auditory training program on the behavioral, electrophysiological and subjective aspects of auditory function in individuals with bilateral high-frequency hearing loss. METHOD: A prospective study of seven individuals aged 46 to 57 years with symmetric, moderate high-frequency hearing loss ranging from 3 to 8 kHz was conducted. Evaluations of auditory processing (sound location, verbal and non-verbal sequential memory tests, the speech-in-noise test, the staggered spondaic word test, synthetic sentence identification with competitive ipsilateral and contralateral competitive messages, random gap detection and the standard duration test, auditory brainstem response and long-latency potentials and the administration of the Abbreviated Profile of Hearing Aid Benefit questionnaire were performed in a sound booth before and immediately after formal auditory training. RESULTS: All of the participants demonstrated abnormal pre-training long-latency characteristics (abnormal latency or absence of the P3 component and these abnormal characteristics were maintained in six of the seven individuals at the post-training evaluation. No significant differences were found between ears in the quantitative analysis of auditory brainstem responses or long-latency potentials. However, the subjects demonstrated improvements on all behavioral tests. For the questionnaire, the difference on the background noise subscale achieved statistical significance. CONCLUSION: Auditory training in adults with high-frequency hearing loss led to improvements in figure-background hearing skills for verbal sounds, temporal ordination and resolution, and communication in noisy environments. Electrophysiological changes were also observed because, after the training, some long latency components that were absent pre-training were observed during the re-evaluation.

  11. Audiological results with Baha in conductive and mixed hearing loss.

    Science.gov (United States)

    Pfiffner, Flurin; Caversaccio, Marco-Domenico; Kompis, Martin

    2011-01-01

    The level of improvement in the audiological results of Baha(®) users mainly depends on the patient's preoperative hearing thresholds and the type of Baha sound processor used. This investigation shows correlations between the preoperative hearing threshold and postoperative aided thresholds and audiological results in speech understanding in quiet of 84 Baha users with unilateral conductive hearing loss, bilateral conductive hearing loss and bilateral mixed hearing loss. Secondly, speech understanding in noise of 26 Baha users with different Baha sound processors (Compact, Divino, and BP100) is investigated. Linear regression between aided sound field thresholds and bone conduction (BC) thresholds of the better ear shows highest correlation coefficients and the steepest slope. Differences between better BC thresholds and aided sound field thresholds are smallest for mid-frequencies (1 and 2 kHz) and become larger at 0.5 and 4 kHz. For Baha users, the gain in speech recognition in quiet can be expected to lie in the order of magnitude of the gain in their hearing threshold. Compared to its predecessor sound processors Baha(®) Compact and Baha(®) Divino, Baha(®) BP100 improves speech understanding in noise significantly by +0.9 to +4.6 dB signal-to-noise ratio, depending on the setting and the use of directional microphone. For Baha users with unilateral and bilateral conductive hearing loss and bilateral mixed hearing loss, audiological results in aided sound field thresholds can be estimated with the better BC hearing threshold. The benefit in speech understanding in quiet can be expected to be similar to the gain in their sound field hearing threshold. The most recent technology of Baha sound processor improves speech understanding in noise by an order of magnitude that is well perceived by users and which can be very useful in everyday life. Copyright © 2011 S. Karger AG, Basel.

  12. Bonebridge Implantation for Conductive Hearing Loss in a Patient with Oval Window Atresia.

    Science.gov (United States)

    Kim, Minbum

    2015-08-01

    The occurrence of oval window atresia is a rare anomaly with conductive hearing loss. Traditional atresia surgeries involve challenging surgical techniques with risks of irreversible inner ear damage. Recent reports on Bonebridge (Medel, Innsbruck, Austria), a novel implantable bone conduction hearing aid system, assert that the device is safe and effective for conductive hearing loss. We present a case of Bonebridge implantation in an eight-year-old girl with bilateral oval window atresia.

  13. Uncovering effective strategies for hearing loss prevention

    Science.gov (United States)

    Morata, Thais C.; Meinke, Deanna

    2016-01-01

    Occupational health agencies, researchers and policy makers have recognized the need for evidence on the effectiveness of interventions designed to reduce or prevent workplace injuries and illnesses. While many workplaces comply with legal or obligatory requirements and implement recommended interventions, few publications exist documenting the effectiveness of these actions. Additionally, some workplaces have discovered through their own processes, novel ways to reduce the risk of injury. Peer-reviewed information on the effectiveness of the many strategies and approaches currently in use could help correct weaknesses, or further encourage their adoption and expansion. The evaluation of intervention effectiveness would certainly contribute to improved worker health and safety. This need is particularly relevant regarding noise exposure in the workplace and hearing loss prevention interventions. In a 2006 review of the U.S. National Institute for Occupational Safety and Health (NIOSH) Hearing Loss Research Program, the independent National Academies of Sciences recommended that NIOSH place greater emphasis on identifying the effectiveness of hearing loss prevention measures on the basis of outcomes that are as closely related as possible to reducing noise exposure and work related hearing loss (http://www.nap.edu/openbook.php?record_id=11721). NIOSH used two different approaches to address that recommendation: the first one was to conduct research, including broad systematic reviews on the effectiveness of interventions to prevent occupational noise-induced hearing loss. The second was to create an award program, the Safe-In-Sound Excellence in Hearing Loss Prevention Award™, to identify and honor excellent real-world examples of noise control and other hearing loss prevention practices and innovations. PMID:27397968

  14. Condom Advertising and AIDS. Hearing before the Subcommittee on Health and the Environment of the Committee on Energy and Commerce. House of Representatives, One Hundredth Congress, First Session.

    Science.gov (United States)

    Congress of the U.S., Washington, DC. House Committee on Energy and Commerce.

    This document present witnesses' testimonies from the Congressional hearing called to examine condom advertising and Acquired Immune Deficiency Syndrome (AIDS). Opening statements are included by Congressmen Henry Waxman, William Dannemeyer, and Jim Bates. C. Everett Koop, United States Surgeon General, and Gary Noble, AIDS coordinator for the…

  15. Cochlear implant: Speech and language development in deaf and hard of hearing children following implantation

    Directory of Open Access Journals (Sweden)

    Ostojić Sanja

    2011-01-01

    Full Text Available Bacground/Aim. Almost 200 cochlear implantations were done in the four centers (two in Belgrade, per one in Novi Sad and Niš in Serbia from 2002 to 2009. Less than 10% of implantees were postlingually deaf adults. The vast majority, i.e. 90% were pre- and perilingually profoundly deaf children. The aim of this study was to assess the influence of improved auditory perception due to cochlear implantation on comprehension of abstract words in children as compared with hearing impaired children with conventional hearing aids and normal hearing children. Methods. Thirty children were enrolled in this study: 20 hearing impaired and 10 normal hearing. The vocabulary test was used. Results. The overall results for the whole test (100 words showed a significant difference in favor of the normal hearing as compared with hearing impaired children. The normal hearing children successfully described or defined 77.93% of a total of 100 words. Success rate for the cochlear implanted children was 26.87% and for the hearing impaired children with conventional hearing aids 20.32%. Conclusion. Testing for abstract words showed a statistically significant difference between the cochlear implanted and the hearing impaired children with hearing aids (Mann- Whitney U-test, p = 0.019 implying considerable advantage of cochlear implants over hearing aids regarding successful speech development in prelingually deaf children.

  16. ∑∆ Modulator System-Level Considerations for Hearing-Aid Audio Class-D Output Stage Application

    DEFF Research Database (Denmark)

    Pracný, Peter; Bruun, Erik

    2012-01-01

    This paper deals with a system-level design of a digital sigma-delta (∑∆) modulator for hearing-aid audio Class D output stage application. The aim of this paper is to provide a thorough discussion on various possibilities and tradeoffs of ∑∆ modulator system-level design parameter combinations...... - order, oversampling ratio (OSR) and number of bits in the quantizer - including their impact on interpolation filter design as well. The system is kept in digital domain up to the input of the Class D power stage including the digital pulse width modulation (DPWM) block. Notes on the impact of the DPWM...

  17. Language development in Japanese children who receive cochlear implant and/or hearing aid.

    Science.gov (United States)

    Iwasaki, Satoshi; Nishio, Shinya; Moteki, Hideaki; Takumi, Yutaka; Fukushima, Kunihiro; Kasai, Norio; Usami, Shin-Ichi

    2012-03-01

    This study aimed to investigate a wide variety of factors that influence auditory, speech, and language development following pediatric cochlear implantation (CI). Prospective collection of language tested data in profound hearing-impaired children. Pediatric CI can potentially be effective to development of practical communication skills and early implantation is more effective. We proposed a set of language tests (assessment package of the language development for Japanese hearing-impaired children; ALADJIN) consisting of communication skills testing (test for question-answer interaction development; TQAID), comprehensive (Peabody Picture Vocabulary Test-Revised; PVT-R and Standardized Comprehension Test for Abstract Words; SCTAW) and productive vocabulary (Word Fluency Test; WFT), and comprehensive and productive syntax (Syntactic processing Test for Aphasia; STA). Of 638 hearing-impaired children recruited for this study, 282 (44.2%) with >70 dB hearing impairment had undergone CI. After excluding children with low birth weight (11 points on the Pervasive Developmental Disorder ASJ Rating Scale for the test of autistic tendency, and those better than those in HA-only users. The scores for PVT-R (pbetter than those in HA-only users. STA and TQAID scores in CI-HA users were significantly (pbetter than those in unilateral CI-only users. The high correlation (r=0.52) has been found between the age of CI and maximum speech discrimination score. The scores of speech and language tests in the implanted children before 24 months of age have been better than those in the implanted children after 24 months of age. We could indicate that CI was effective for language development in Japanese hearing-impaired children and early CI was more effective for productive vocabulary and syntax. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  18. Validity and reliability of in-situ air conduction thresholds measured through hearing aids coupled to closed and open instant-fit tips.

    Science.gov (United States)

    O'Brien, Anna; Keidser, Gitte; Yeend, Ingrid; Hartley, Lisa; Dillon, Harvey

    2010-12-01

    Audiometric measurements through a hearing aid ('in-situ') may facilitate provision of hearing services where these are limited. This study investigated the validity and reliability of in-situ air conduction hearing thresholds measured with closed and open domes relative to thresholds measured with insert earphones, and explored sources of variability in the measures. Twenty-four adults with sensorineural hearing impairment attended two sessions in which thresholds and real-ear-to-dial-difference (REDD) values were measured. Without correction, significantly higher low-frequency thresholds in dB HL were measured in-situ than with insert earphones. Differences were due predominantly to differences in ear canal SPL, as measured with the REDD, which were attributed to leaking low-frequency energy. Test-retest data yielded higher variability with the closed dome coupling due to inconsistent seals achieved with this tip. For all three conditions, inter-participant variability in the REDD values was greater than intra-participant variability. Overall, in-situ audiometry is as valid and reliable as conventional audiometry provided appropriate REDD corrections are made and ambient sound in the test environment is controlled.

  19. Self-Esteem in Children and Adolescents With Hearing Loss

    OpenAIRE

    Warner-Czyz, Andrea D.; Loy, Betty A.; Evans, Christine; Wetsel, Ashton; Tobey, Emily A.

    2015-01-01

    Children with hearing loss are at risk for lower self-esteem due to differences from hearing peers relative to communication skills, physical appearance, and social maturity. This study examines the influence of generic factors unrelated to hearing loss (e.g., age, gender, temperament) and specific factors associated with hearing loss (e.g., age at identification, communication skills) on how children with hearing loss wearing cochlear implants or hearing aids appraise self-esteem. Fifty chil...

  20. A 155µW 88-dB DR discrete-time delta-sigma modulator for digital hearing aids exploiting a summing SAR ADC Quantizer

    NARCIS (Netherlands)

    Porrazzo, S.; Morgado, A.; San Segundo Bello, D.; Cannillo, F.; Van Hoof, C.; Yazicioglu, R.F.; Roermund, van Arthur; Cantatore, Eugenio

    2013-01-01

    This paper presents a low-power switched-capacitor $Delta Sigma$ modulator for digital hearing-aid applications that features a novel summing successive approximation (SAR). The summing SAR performs multi-bit quantization together with the analog addition required in feed-forward (FF) $Delta Sigma$

  1. Understanding history, philanthropy and the role of WHO in provision of assistive technologies for hearing loss.

    Science.gov (United States)

    Chadha, Shelly; Moussy, Francis; Friede, Martin Howell

    2014-09-01

    Philanthropy continues to play an important role in provision of hearing devices and is often the only alternative for the majority of those in need of these devices. While this leads to improved access to services it may also create unsustainable service delivery models. Over the past decade, World Health Organization (WHO) has been making consistent efforts towards promoting accessibility and affordability of high-quality hearing devices, especially in Low- and Middle-Income Countries (LMIC). WHO developed and updated the "Guidelines for Hearing Aids and Services in Developing Countries", in 2004. In 2006, WHO supported the establishment of "World Wide (WW) Hearing", to promote hearing aid access across the globe. In the past year, WHO has renewed these efforts. As the first step and following a consultation on promoting access to hearing devices, WHO has developed a preferred product profile in order to facilitate the development and access of appropriate and affordable hearing aids for developing countries. The Convention on the Rights of Persons with Disabilities (article 32), calls for international collaboration to promote access to assistive technology including hearing devices. A coordinated global effort is required to promote availability and affordability of high-quality hearing devices. Such an undertaking requires the cooperation of all stakeholders: WHO, Member States, Non-Governmental Organizations (NGOs), philanthropists, manufacturers and users, to fulfill the international obligation and bring about a change in the quality of life of millions of people with hearing loss. Development of preferred product profile for hearing aids in LMICs can improve development and provision of high-quality, affordable hearing devices. Investment made by the recipients, such as partial financial contribution towards the cost of device or through purchase of ear mould or batteries, leads to a greater sense of responsibility towards the device and its maintenance

  2. Hearing Loss in HIV-Infected Children in Lilongwe, Malawi.

    Science.gov (United States)

    Hrapcak, Susan; Kuper, Hannah; Bartlett, Peter; Devendra, Akash; Makawa, Atupele; Kim, Maria; Kazembe, Peter; Ahmed, Saeed

    2016-01-01

    With improved access to antiretroviral therapy (ART), HIV infection is becoming a chronic illness. Preliminary data suggest that HIV-infected children have a higher risk of disabilities, including hearing impairment, although data are sparse. This study aimed to estimate the prevalence and types of hearing loss in HIV-infected children in Lilongwe, Malawi. This was a cross-sectional survey of 380 HIV-infected children aged 4-14 years attending ART clinic in Lilongwe between December 2013-March 2014. Data was collected through pediatric quality of life and sociodemographic questionnaires, electronic medical record review, and detailed audiologic testing. Hearing loss was defined as >20 decibels hearing level (dBHL) in either ear. Predictors of hearing loss were explored by regression analysis generating age- and sex-adjusted odds ratios. Children with significant hearing loss were fitted with hearing aids. Of 380 patients, 24% had hearing loss: 82% conductive, 14% sensorineural, and 4% mixed. Twenty-one patients (23% of those with hearing loss) were referred for hearing aid fitting. There was a higher prevalence of hearing loss in children with history of frequent ear infections (OR 7.4, 4.2-13.0) and ear drainage (OR 6.4, 3.6-11.6). Hearing loss was linked to history of WHO Stage 3 (OR 2.4, 1.2-4.5) or Stage 4 (OR 6.4, 2.7-15.2) and history of malnutrition (OR 2.1, 1.3-3.5), but not to duration of ART or CD4. Only 40% of caregivers accurately perceived their child's hearing loss. Children with hearing impairment were less likely to attend school and had poorer emotional (p = 0.02) and school functioning (p = 0.04). There is an urgent need for improved screening tools, identification and treatment of hearing problems in HIV-infected children, as hearing loss was common in this group and affected school functioning and quality of life. Clear strategies were identified for prevention and treatment, since most hearing loss was conductive in nature, likely due to

  3. Development of a Bone-Conducted Ultrasonic Hearing Aid for the Profoundly Deaf: Evaluation of Sound Quality Using a Semantic Differential Method

    Science.gov (United States)

    Nakagawa, Seiji; Fujiyuki, Chika; Kagomiya, Takayuki

    2013-07-01

    Bone-conducted ultrasound (BCU) is perceived even by the profoundly sensorineural deaf. A novel hearing aid using the perception of amplitude-modulated BCU (BCU hearing aid: BCUHA) has been developed. However, there is room for improvement particularly in terms of sound quality. BCU speech is accompanied by a strong high-pitched tone and contain some distortion. In this study, the sound quality of BCU speech with several types of amplitude modulation [double-sideband with transmitted carrier (DSB-TC), double-sideband with suppressed carrier (DSB-SC), and transposed modulations] and air-conducted (AC) speech was quantitatively evaluated using semantic differential and factor analysis. The results showed that all the types of BCU speech had higher metallic and lower esthetic factor scores than AC speech. On the other hand, transposed speech was closer than the other types of BCU speech to AC speech generally; the transposed speech showed a higher powerfulness factor score than the other types of BCU speech and a higher esthetic factor score than DSB-SC speech. These results provide useful information for further development of the BCUHA.

  4. Direcionalidade e redução de ruído em AASI: percepção de fala e benefício Directivity and noise reduction in hearing aids: speech perception and benefit

    Directory of Open Access Journals (Sweden)

    Camila Angélica Quintino

    2010-10-01

    Full Text Available Aparelho de Amplificação Sonora Individual (AASI. OBJETIVO: Comparar o desempenho, benefício e a satisfação de usuários de AASI intra-aural e retroauricular digital com algoritmo de redução de ruído e microfones omnidirecional e direcional. MATERIAL E MÉTODO: 34 usuários de AASI digital foram avaliados por meio do reconhecimento de sentenças no ruído e dos questionários APHAB e IOI. Estudo prospectivo. RESULTADOS: Melhores resultados foram obtidos com AASI intra-aurais e AASI direcionais, no entanto, não houve diferença estatística significante entre os grupos. CONCLUSÃO: A direcionalidade favoreceu o reconhecimento de fala no ruído e o benefício obtido em vida diária.Hearing aid. AIM: To compare the performance, benefit and satisfaction of users of ITE, CIC and BTE digital hearing aid with noise reduction and omnidirectional and directional microphones. METHOD: 34 users of hearing aid were evaluated by means of speech perception in noise tests and APHAB and IOI self assessment questionnaires. Prospective study. RESULTS: Better results were obtained by users of ITE, CIC and directional hearing aids, however, no statistical significance was found between the groups. CONCLUSION: Directivity improved speech perception in noise and benefit in daily life situations.

  5. Correlação entre as restrições de participação em atividades de vida diária e o benefício do uso de próteses auditivas em adultos e idosos Correlation between the handicap and the benefit of hearing aid use in adults and elderly

    Directory of Open Access Journals (Sweden)

    Vívian Baptista da Luz

    2011-06-01

    : Participants were 42 individuals attended at the institution where the study was carried. They answered the questionnaires Hearing Handicap Inventory for Elderly or for Adults, and Abbreviated Profile of Hearing Aid Benefit both when they received the hearing aids and after three months of its effective use. The participation constraints, hearing difficulties and the benefit brought by the use of hearing aids were studied. The results were statistically analyzed. RESULTS: There were differences between the scores from the questionnaires Hearing Handicap Inventory for Elderly and Hearing Handicap Inventory for Adults and the subscales Ease of Communication, Reverberation and Background Noise from the Abbreviated Profile of Hearing Aid Benefit, comparing the conditions with and without hearing aids. There was a positive correlation between the benefit measured by the subscale Ease of Communication, for the elderly subjects, and Background Noise, for the adult subjects, with decrease of the participation constraint. CONCLUSION: Adult and elderly subjects showed a reduction of handicap in daily activities with the use of hearing aids. The bigger the benefit obtained in the subscale Ease of Communication for the elderly and in the subscale Background Noise for the adults, the greater the handicap reduction.

  6. 22 CFR 216.8 - Public hearings.

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Public hearings. 216.8 Section 216.8 Foreign Relations AGENCY FOR INTERNATIONAL DEVELOPMENT ENVIRONMENTAL PROCEDURES § 216.8 Public hearings. (a) In most instances AID will be able to gain the benefit of public participation in the impact statement process...

  7. Hearing in young adults. Part I: The effects of attitudes and beliefs toward noise, hearing loss, and hearing protector devices

    Directory of Open Access Journals (Sweden)

    Hannah Keppler

    2015-01-01

    Full Text Available There is great concern regarding the development of noise-induced hearing loss (NIHL in youth caused by high sound levels during various leisure activities. Health-orientated behavior of young adults might be linked to the beliefs and attitudes toward noise, hearing loss, and hearing protector devices (HPDs. The objective of the current study was to evaluate the effects of attitudes and beliefs toward noise, hearing loss, and HPDs on young adults′ hearing status. A questionnaire and an audiological test battery were completed by 163 subjects (aged 18-30 years. The questionnaire contained the Youth Attitude to Noise Scale (YANS and Beliefs about Hearing Protection and Hearing Loss (BAHPHL. A more positive attitude or belief represented an attitude where noise or hearing loss is seen as unproblematic and attitudes and beliefs regarding HPDs is worse. Hearing was evaluated using (high frequency pure tone audiometry (PTA, transient evoked and distortion product otoacoustic emissions. First, mean differences in hearing between the groups with different attitudes and beliefs were evaluated using one-way analysis of variance (ANOVA. Second, a χ2 test was used to examine the usage of HPDs by the different groups with different attitudes and beliefs. Young adults with a positive attitude had significantly more deteriorated hearing and used HPDs less than the other subjects. Hearing conservation programs (HCPs for young adults should provide information and knowledge regarding noise, hearing loss, and HPDs. Barriers wearing HPDs should especially be discussed. Further, those campaigns should focus on self-experienced hearing related symptoms that might serve as triggers for attitudinal and behavioral changes.

  8. [Prevalence of hearing loss in Northern and Southern Germany. German version].

    Science.gov (United States)

    von Gablenz, P; Hoffmann, E; Holube, I

    2017-08-01

    The HÖRSTAT study conducted in Northwest Germany yielded hearing impairment in approximately 16% of adults according to the World Health Organization (WHO) criterion. However, the robustness of extrapolations on a national level might be questioned, as the epidemiological data were collected on a regional level. Independently from HÖRSTAT, the "Hearing in Germany" study examined adult hearing in Aalen, a town located in Southwest Germany. Both cross-sectional studies were based on stratified random samples from the general population. Pure-tone average at 0.5, 1, 2, and 4 kHz (PTA4), the prevalence of hearing impairment (WHO criterion: PTA4 in the better ear >25 dB HL), and hearing aid provision were compared. Data from the Aalen study and HÖRSTAT were pooled (n = 3105) to extrapolate the prevalence and degree of hearing impairment for the years 2015, 2020, and 2025. Both studies show very similar results for PTA4. Weighted for official population statistics, the prevalence of hearing impairment according to the WHO criterion is 16.2% among adults, affecting 11.1 million persons in Germany. Due to demographic changes, the prevalence is expected to increase in the medium term by around 1% per 5‑year period. With a similar degree of hearing loss, hearing aid provision differs from place to place. Adjusted for gender and age to the European Standard Population (ESP), the prevalence of hearing impairment observed both in HÖRSTAT and the Aalen sample is considerably lower than reported for international studies. Since the analysis refers to cross-sectional data only, possible cohort effects are not considered in the prevalence projection.

  9. Vocabulary and working memory in children fit with hearing aids.

    Science.gov (United States)

    Stiles, Derek J; McGregor, Karla K; Bentler, Ruth A

    2012-02-01

    To determine whether children with mild-to-moderately severe sensorineural hearing loss (CHL) present with disturbances in working memory and whether these disturbances relate to the size of their receptive vocabularies. Children 6 to 9 years of age participated. Aspects of working memory were tapped by articulation rate, forward and backward digit span in the auditory and visual modalities, Corsi span, parent surveys, and a sequential encoding task. Articulation rate, digit spans, and Corsi spans were also administered in low-level broadband noise. CHL and children with normal hearing (CNH) demonstrated auditory advantage in forward serial recall. CHL demonstrated slower articulation rates than CNH, but similar memory spans. CHL with poor executive function presented with poorer performance on the Corsi span task. The presence of background noise had no effect on performance in either group. CHL presented with significantly smaller receptive vocabularies than their CNH peers. Across groups, receptive vocabulary size was positively correlated with digit span in quiet, Corsi span in noise, and articulation rate. In the presence of mild-to-moderately severe hearing loss, children demonstrated resilient working memory systems. For all children, working memory and vocabulary were related; that is, children with poorer working memory had smaller vocabulary sizes.

  10. Current amplification models of sensorineurall and conductive hearing loss

    OpenAIRE

    Ostojić, Sanja; Mikić, Branka; Mirić, Danica

    2012-01-01

    The main function of a hearing aid is to improve auditory and language abilities of hearing impaired users. The amplification model has to be adapted according to age, degree and type of hearing loss. The goal of this paper is to analyze the current amplification models of sensorineural and conductive hearing loss which can provide a high quality of speech perception and sounds at any degree of hearing loss. The BAHA is a surgically implantable system for treatment of conductive hearing loss ...

  11. 28 CFR 36.303 - Auxiliary aids and services.

    Science.gov (United States)

    2010-07-01

    ... materials available to individuals with hearing impairments; (2) Qualified readers, taped texts, audio recordings, Brailled materials, large print materials, or other effective methods of making visually...” includes— (1) Qualified interpreters, notetakers, computer-aided transcription services, written materials...

  12. Effects of venting on wind noise levels measured at the eardrum.

    Science.gov (United States)

    Chung, King

    2013-01-01

    Wind noise can be a nuisance to hearing aid users. With the advent of sophisticated feedback reduction algorithms, people with higher degrees of hearing loss are fit with larger vents than previously allowed, and more people with lesser degrees of hearing loss are fit with open hearing aids. The purpose of this study was to examine the effects of venting on wind noise levels in the ear canal for hearing aids with omnidirectional and directional microphones. Two behind-the-ear hearing aids were programmed when they were worn on a Knowles Electronics Manikin for Acoustic Research. The hearing aid worn on the right ear was programmed to the omnidirectional microphone mode and the one on the left to the directional microphone mode. The hearing aids were adjusted to linear amplification with flat frequency response in an anechoic chamber. Gains below 10 dB were used to avoid output limiting of wind noise levels at low input levels. Wind noise samples were recorded at the eardrum location in a wind tunnel at wind velocities ranging from a gentle to a strong breeze. The hearing aids were coupled to #13 tubings (i.e., open vent), or conventional skeleton earmolds with no vent, pressure vents, or 3mm vents. Polar and spectral characteristics of wind noise were analyzed off-line using MatLab programs. Wind noise levels in the ear canals were mostly predicted by vent-induced frequency response changes in the conventional earmold conditions for both omnidirectional and directional hearing aids. The open vent condition, however, yielded the lowest levels, which could not be entirely predicted by the frequency response changes of the hearing aids. This indicated that a wind-related vent effect permitted an additional amount of sound reduction in the ear canal, which could not be explained by known vent effects. For the microphone location, form factor, and gain settings tested, open fit hearing aids yielded lower noise levels at the eardrum location than conventional behind

  13. Self-esteem in children and adolescents with hearing loss.

    Science.gov (United States)

    Warner-Czyz, Andrea D; Loy, Betty A; Evans, Christine; Wetsel, Ashton; Tobey, Emily A

    2015-03-09

    Children with hearing loss are at risk for lower self-esteem due to differences from hearing peers relative to communication skills, physical appearance, and social maturity. This study examines the influence of generic factors unrelated to hearing loss (e.g., age, gender, temperament) and specific factors associated with hearing loss (e.g., age at identification, communication skills) on how children with hearing loss wearing cochlear implants or hearing aids appraise self-esteem. Fifty children with hearing loss wearing cochlear implants or hearing aids participated (Mean age: 12.88 years; mean duration of device use: 3.43 years). Participants independently completed online questionnaires to assess communication skills, social engagement, self-esteem, and temperament. Children with hearing loss rated global self-esteem significantly more positively than hearing peers, t = 2.38, p = .02. Self-esteem ratings attained significant positive correlations with affiliation (r = .42, p = .002) and attention (r = .45, p = .001) temperaments and a significant negative association with depressive mood (r = - .60, p self-esteem and demographic factors, communication skills, or social engagement. Because successful communication abilities do not always co-occur with excellent quality of life, clinicians and professionals working with children with hearing loss need to understand components contributing to self-esteem to improve identification, counseling, and external referrals for children in this population. © The Author(s) 2015.

  14. Self-Esteem in Children and Adolescents With Hearing Loss

    Science.gov (United States)

    Loy, Betty A.; Evans, Christine; Wetsel, Ashton; Tobey, Emily A.

    2015-01-01

    Children with hearing loss are at risk for lower self-esteem due to differences from hearing peers relative to communication skills, physical appearance, and social maturity. This study examines the influence of generic factors unrelated to hearing loss (e.g., age, gender, temperament) and specific factors associated with hearing loss (e.g., age at identification, communication skills) on how children with hearing loss wearing cochlear implants or hearing aids appraise self-esteem. Fifty children with hearing loss wearing cochlear implants or hearing aids participated (Mean age: 12.88 years; mean duration of device use: 3.43 years). Participants independently completed online questionnaires to assess communication skills, social engagement, self-esteem, and temperament. Children with hearing loss rated global self-esteem significantly more positively than hearing peers, t = 2.38, p = .02. Self-esteem ratings attained significant positive correlations with affiliation (r = .42, p = .002) and attention (r = .45, p = .001) temperaments and a significant negative association with depressive mood (r = − .60, p self-esteem and demographic factors, communication skills, or social engagement. Because successful communication abilities do not always co-occur with excellent quality of life, clinicians and professionals working with children with hearing loss need to understand components contributing to self-esteem to improve identification, counseling, and external referrals for children in this population. PMID:25755025

  15. Presbycusis, part 1: can you hear the music of life?

    Science.gov (United States)

    Hutchison, Barbara; Covan, Eleanor K; Bogus, Janet C

    2012-01-01

    We used a novel approach allowing participants in this study to self-monitor their hearing sensitivity to familiar sounds in the environment. The objective of this approach was to establish whether participants in the 80-89 and 90-99 age groups would recognize the degree of their hearing impairment. It was our hope that participants would value audiology treatment and that it would improve their quality of life over a short period. The pilot study took place in a clinical environment where participants answered survey questions before and after audiology treatment, which pertained to their hearing impairment, morale, social support, and life satisfaction. Caregivers were included in the research to rate and record participants' problem behaviors (e.g., shouting, anger, agitation, repetitive speech dialog, and depression) before, during, and after treatment. This research validates other scientists' findings that annoying problem behaviors may actually be the result of hearing loss because of a person's inability to recognize speech. The pilot study shows that participants with mild dementia adapted well to speech and sounds in the natural environment without agitation as well as to management of hearing aids within a 30-day period. The participants with moderate dementia were slower to adapt. All participants with dementia required the cooperation of their caregivers to maintain hygiene of ear canals and hearing aids and insertion. This study suggests that the sooner people receive treatment for hearing loss, the quicker they are to recognize speech and to master hearing aid technology.

  16. Hearing loss and disability exit: Measurement issues and coping strategies.

    Science.gov (United States)

    Christensen, Vibeke Tornhøj; Datta Gupta, Nabanita

    2017-02-01

    Hearing loss is one of the most common conditions related to aging, and previous descriptive evidence links it to early exit from the labor market. These studies are usually based on self-reported hearing difficulties, which are potentially endogenous to labor supply. We use unique representative data collected in the spring of 2005 through in-home interviews. The data contains self-reported functional and clinically-measured hearing ability for a representative sample of the Danish population aged 50-64. We estimate the causal effect of hearing loss on early retirement via disability benefits, taking into account the endogeneity of functional hearing. Our identification strategy involves the simultaneous estimation of labor supply, functional hearing, and coping strategies (i.e. accessing assistive devices at work or informing one's employer about the problem). We use hearing aids as an instrument for functional hearing. Our main empirical findings are that endogeneity bias is more severe for men than women and that functional hearing problems significantly increase the likelihood of receiving disability benefits for both men and women. However, relative to the baseline the effect is larger for men (47% vs. 20%, respectively). Availability of assistive devices in the workplace decreases the likelihood of receiving disability benefits, whereas informing an employer about hearing problems increases this likelihood. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Hearing Loss in HIV-Infected Children in Lilongwe, Malawi

    Science.gov (United States)

    Hrapcak, Susan; Kuper, Hannah; Bartlett, Peter; Devendra, Akash; Makawa, Atupele; Kim, Maria; Kazembe, Peter; Ahmed, Saeed

    2016-01-01

    Introduction With improved access to antiretroviral therapy (ART), HIV infection is becoming a chronic illness. Preliminary data suggest that HIV-infected children have a higher risk of disabilities, including hearing impairment, although data are sparse. This study aimed to estimate the prevalence and types of hearing loss in HIV-infected children in Lilongwe, Malawi. Methods This was a cross-sectional survey of 380 HIV-infected children aged 4–14 years attending ART clinic in Lilongwe between December 2013-March 2014. Data was collected through pediatric quality of life and sociodemographic questionnaires, electronic medical record review, and detailed audiologic testing. Hearing loss was defined as >20 decibels hearing level (dBHL) in either ear. Predictors of hearing loss were explored by regression analysis generating age- and sex-adjusted odds ratios. Children with significant hearing loss were fitted with hearing aids. Results Of 380 patients, 24% had hearing loss: 82% conductive, 14% sensorineural, and 4% mixed. Twenty-one patients (23% of those with hearing loss) were referred for hearing aid fitting. There was a higher prevalence of hearing loss in children with history of frequent ear infections (OR 7.4, 4.2–13.0) and ear drainage (OR 6.4, 3.6–11.6). Hearing loss was linked to history of WHO Stage 3 (OR 2.4, 1.2–4.5) or Stage 4 (OR 6.4, 2.7–15.2) and history of malnutrition (OR 2.1, 1.3–3.5), but not to duration of ART or CD4. Only 40% of caregivers accurately perceived their child’s hearing loss. Children with hearing impairment were less likely to attend school and had poorer emotional (p = 0.02) and school functioning (p = 0.04). Conclusions There is an urgent need for improved screening tools, identification and treatment of hearing problems in HIV-infected children, as hearing loss was common in this group and affected school functioning and quality of life. Clear strategies were identified for prevention and treatment, since most

  18. Internet Interventions for Hearing Loss.

    Science.gov (United States)

    Thorén, Elisabet Sundewall; Öberg, Marie; Andersson, Gerhard; Lunner, Thomas

    2015-09-01

    The purpose of the two studies presented in this research forum article was to develop audiological rehabilitation programs for experienced hearing aid users and evaluate them in online versions. In this research forum article, the differences between the two studies are discussed. Two randomized controlled trials (RCTs) were performed evaluating the efficacy of online rehabilitation, including professional guidance by an audiologist. In each RCT, the effects of the online programs were compared with the effects measured in a control group. The results from the first RCT showed a significant increase in activity and participation for both groups with participants in the intervention group improving more than those in the control group. At the 6-month follow-up, after the study, the significant increase was maintained; however, amounts of increase in the two groups were no longer significantly different. The results from the second RCT showed significant increase in activity and participation for the intervention group, although the control group did not improve. The results from the RCTs provide evidence that the Internet can be used to deliver rehabilitation to hearing-aid users and that their problems are reduced by the intervention; however, the content of the online rehabilitation program requires further investigation.

  19. Low empathy in deaf and hard of hearing (preadolescents compared to normal hearing controls.

    Directory of Open Access Journals (Sweden)

    Anouk P Netten

    Full Text Available The purpose of this study was to examine the level of empathy in deaf and hard of hearing (preadolescents compared to normal hearing controls and to define the influence of language and various hearing loss characteristics on the development of empathy.The study group (mean age 11.9 years consisted of 122 deaf and hard of hearing children (52 children with cochlear implants and 70 children with conventional hearing aids and 162 normal hearing children. The two groups were compared using self-reports, a parent-report and observation tasks to rate the children's level of empathy, their attendance to others' emotions, emotion recognition, and supportive behavior.Deaf and hard of hearing children reported lower levels of cognitive empathy and prosocial motivation than normal hearing children, regardless of their type of hearing device. The level of emotion recognition was equal in both groups. During observations, deaf and hard of hearing children showed more attention to the emotion evoking events but less supportive behavior compared to their normal hearing peers. Deaf and hard of hearing children attending mainstream education or using oral language show higher levels of cognitive empathy and prosocial motivation than deaf and hard of hearing children who use sign (supported language or attend special education. However, they are still outperformed by normal hearing children.Deaf and hard of hearing children, especially those in special education, show lower levels of empathy than normal hearing children, which can have consequences for initiating and maintaining relationships.

  20. Detection threshold for sound distortion resulting from noise reduction in normal-hearing and hearing-impaired listeners.

    Science.gov (United States)

    Brons, Inge; Dreschler, Wouter A; Houben, Rolph

    2014-09-01

    Hearing-aid noise reduction should reduce background noise, but not disturb the target speech. This objective is difficult because noise reduction suffers from a trade-off between the amount of noise removed and signal distortion. It is unknown if this important trade-off differs between normal-hearing (NH) and hearing-impaired (HI) listeners. This study separated the negative effect of noise reduction (distortion) from the positive effect (reduction of noise) to allow the measurement of the detection threshold for noise-reduction (NR) distortion. Twelve NH subjects and 12 subjects with mild to moderate sensorineural hearing loss participated in this study. The detection thresholds for distortion were determined using an adaptive procedure with a three-interval, two-alternative forced-choice paradigm. Different levels of distortion were obtained by changing the maximum amount of noise reduction. Participants were also asked to indicate their preferred NR strength. The detection threshold for overall distortion was higher for HI subjects than for NH subjects, suggesting that stronger noise reduction can be applied for HI listeners without affecting the perceived sound quality. However, the preferred NR strength of HI listeners was closer to their individual detection threshold for distortion than in NH listeners. This implies that HI listeners tolerate fewer audible distortions than NH listeners.

  1. Desenvolvimento de prótese auditiva digital para atendimento da Portaria nº 587 (APAC do Ministério da Saúde: Health Department Development of a digital hearing aid to meet the Brazilian Government's Ordinance 587 (APAC

    Directory of Open Access Journals (Sweden)

    Silvio Pires Penteado

    2010-06-01

    Full Text Available O tratamento das disacusias sensório-neurais está balizado no uso de próteses auditivas, conhecidas como aparelhos auditivos ou aparelhos de amplificação sonora individuais. As próteses auditivas adquiridas pelo Governo Brasileiro para a condução de políticas públicas têm como uma de suas características a utilização de componentes dedicados, o que traz benefícios, mas que encarece a aquisição e pode inviabilizar os serviços de reparo após o término da garantia do fabricante. OBJETIVO: Desenvolver próteses auditivas digitais no desenho retroauricular, construídas a partir de componentes padronizados oriundos da própria cadeia de suprimentos dos fabricantes de próteses auditivas. FORMA DE ESTUDO: Experimental. MATERIAL E MÉTODO: Identificar a cadeia de suprimentos destes fabricantes, solicitar amostras e montar próteses auditivas em laboratório. RESULTADOS: As próteses auditivas desenvolvidas apresentaram recursos eletroacústicos não inferiores àquelas adquiridas pelo Governo, sendo adicionalmente atestadas pela mesma norma técnica internacional de referência. CONCLUSÃO: É possível desenvolver próteses auditivas digitais no desenho retroauricular montados a partir de componentes padronizados da cadeia de suprimentos dos fabricantes de próteses auditivas. Suas vantagens residem no baixo custo operacional - aquisição (com vantagens para o Governo e de manutenção (com vantagens para o paciente.The treatment of sensorineural hearing loss is based on hearing aids, also known as individual sound amplification devices. The hearing aids purchased by the Brazilian Government, aiming at fulfilling public policies, are based on dedicated components, which bring about benefits, but also render them expensive and may impair repair services after manufacture's warranty expires. AIM: to design digital behind-the-ear hearing aids built from standardized components coming from the very supply chain of these manufacturers

  2. AID SELECTIVITY PRACTICE AND AID EFFECTIVENESS IN SUB-SAHARAN AFRICA

    Directory of Open Access Journals (Sweden)

    Adeniyi Jimmy Adedokun

    2017-09-01

    Full Text Available Foreign aid strategies have undergone restructuring as donors adopt aid selectivity practice to improve aid effectiveness. This study investigates the impact of aid selectivity practice on aid effectiveness (aid-growth relationship in Sub-Saharan Africa (SSA and several groups of countries within SSA from 1980 to 2012. Employing system generalized methods of moments (system GMM technique; the study produces strong evidence that there is significant improvement in aid effectiveness due to aid selectivity practice.

  3. Self-Esteem in Children and Adolescents With Hearing Loss

    Directory of Open Access Journals (Sweden)

    Andrea D. Warner-Czyz

    2015-03-01

    Full Text Available Children with hearing loss are at risk for lower self-esteem due to differences from hearing peers relative to communication skills, physical appearance, and social maturity. This study examines the influence of generic factors unrelated to hearing loss (e.g., age, gender, temperament and specific factors associated with hearing loss (e.g., age at identification, communication skills on how children with hearing loss wearing cochlear implants or hearing aids appraise self-esteem. Fifty children with hearing loss wearing cochlear implants or hearing aids participated (Mean age: 12.88 years; mean duration of device use: 3.43 years. Participants independently completed online questionnaires to assess communication skills, social engagement, self-esteem, and temperament. Children with hearing loss rated global self-esteem significantly more positively than hearing peers, t = 2.38, p = .02. Self-esteem ratings attained significant positive correlations with affiliation (r = .42, p = .002 and attention (r = .45, p = .001 temperaments and a significant negative association with depressive mood (r = − .60, p < .0001. No significant correlations emerged between self-esteem and demographic factors, communication skills, or social engagement. Because successful communication abilities do not always co-occur with excellent quality of life, clinicians and professionals working with children with hearing loss need to understand components contributing to self-esteem to improve identification, counseling, and external referrals for children in this population.

  4. Dialogue enabling speech-to-text user assistive agent system for hearing-impaired person.

    Science.gov (United States)

    Lee, Seongjae; Kang, Sunmee; Han, David K; Ko, Hanseok

    2016-06-01

    A novel approach for assisting bidirectional communication between people of normal hearing and hearing-impaired is presented. While the existing hearing-impaired assistive devices such as hearing aids and cochlear implants are vulnerable in extreme noise conditions or post-surgery side effects, the proposed concept is an alternative approach wherein spoken dialogue is achieved by means of employing a robust speech recognition technique which takes into consideration of noisy environmental factors without any attachment into human body. The proposed system is a portable device with an acoustic beamformer for directional noise reduction and capable of performing speech-to-text transcription function, which adopts a keyword spotting method. It is also equipped with an optimized user interface for hearing-impaired people, rendering intuitive and natural device usage with diverse domain contexts. The relevant experimental results confirm that the proposed interface design is feasible for realizing an effective and efficient intelligent agent for hearing-impaired.

  5. AID SELECTIVITY PRACTICE AND AID EFFECTIVENESS IN SUB-SAHARAN AFRICA

    OpenAIRE

    Adedokun, Adeniyi Jimmy; Abiodun O. Folawewo, Abiodun O.

    2017-01-01

    Foreign aid strategies have undergone restructuring as donors adopt aid selectivity practice to improve aid effectiveness. This study investigates the impact of aid selectivity practice on aid effectiveness (aid-growth relationship) in Sub-Saharan Africa (SSA) and several groups of countries within SSA from 1980 to 2012. Employing system generalized methods of moments (system GMM) technique; the study produces strong evidence that there is significant improvement in aid effectiveness due to a...

  6. Masking Release in Children and Adults with Hearing Loss When Using Amplification

    Science.gov (United States)

    Brennan, Marc; McCreery, Ryan; Kopun, Judy; Lewis, Dawna; Alexander, Joshua; Stelmachowicz, Patricia

    2016-01-01

    Purpose: This study compared masking release for adults and children with normal hearing and hearing loss. For the participants with hearing loss, masking release using simulated hearing aid amplification with 2 different compression speeds (slow, fast) was compared. Method: Sentence recognition in unmodulated noise was compared with recognition…

  7. Evaluating the short-term and long-term effects of an internet-based aural rehabilitation programme for hearing aid users in general clinical practice: a randomised controlled trial.

    Science.gov (United States)

    Malmberg, Milijana; Lunner, Thomas; Kähäri, Kim; Andersson, Gerhard

    2017-06-06

    Guided internet-based intervention beyond hearing aid (HA) fitting has been shown to be efficacious in randomised controlled trials (RCTs). However, internet interventions have rarely been applied clinically as a part of regular aural rehabilitation (AR). Our aim was to evaluate the effectiveness of internet-based AR for HA users from a clinical population. The Hearing Handicap Inventory for the Elderly (HHIE) was used as the primary outcome measure, and the Communication Strategies Scale (CSS) and the Hospital Anxiety and Depression Scale were used as secondary outcome measures. All questionnaires were administered before and directly after the intervention and at 6 months postintervention. We used a parallel group design (RCT). The data were collected in 2013-2014 at three different clinics. Seventy-four HA users were randomly assigned to receive either full internet-based AR (intervention group, n=37) or one element of the internet-based AR (control group, n=37). Data were analysed following the intention-to-treat principle. Each group showed improved HHIE scores over time and did not differ significantly from each other. The intervention group showed significantly greater improvement compared with the control group for the CSS total and the non-verbal subscale scores. The intervention group and control group were also subdivided into two age groups: 20-59 years and 60-80 years. Significantly better improvement on the CSS total and non-verbal subscale scores was found in the older group compared with the younger participants. This study indicates that participants in an internet-based intervention applied in general clinical practice showed improved self-reported communication skills compared with a control group. Receiving a full intervention was not more effective in improving self-reported hearing problems than receiving just one element of the internet-based intervention. This trial is registered at ClinicalTrals.gov, NCT01837550; results. © Article author

  8. Investigation of symphony orchestra musicians' use of hearing protectors

    DEFF Research Database (Denmark)

    Poulsen, Torben; Koskinen, Heli

    2010-01-01

    A questionnaire study was performed about the use of hearing protectors in Danish symphony orchestras. The musicians in three Danish symphony orchestras were asked to complete a questionnaire about their use of hearing protection. A total of 146 musicians filled in the questionnaire. Results show...... an investigation is performed about the use of hearing aids as hearing protectors by symphony orchestra musicians. Preliminary results from this investigation will be presented at the conference....

  9. Relating hearing loss and executive functions to hearing aid users’ preference for, and speech recognition with, different combinations of binaural noise reduction and microphone directionality

    Directory of Open Access Journals (Sweden)

    Tobias eNeher

    2014-12-01

    Full Text Available Knowledge of how executive functions relate to preferred hearing aid (HA processing is sparse and seemingly inconsistent with related knowledge for speech recognition outcomes. This study thus aimed to find out if (1 performance on a measure of reading span (RS is related to preferred binaural noise reduction (NR strength, (2 similar relations exist for two different, nonverbal measures of executive function, (3 pure-tone average hearing loss (PTA, signal-to-noise ratio (SNR, and microphone directionality (DIR also influence preferred NR strength, and (4 preference and speech recognition outcomes are similar. Sixty elderly HA users took part. Six HA conditions consisting of omnidirectional or cardioid microphones followed by inactive, moderate, or strong binaural NR as well as linear amplification were tested. Outcome was assessed at fixed SNRs using headphone simulations of a frontal target talker in a busy cafeteria. Analyses showed positive effects of active NR and DIR on preference, and negative and positive effects of, respectively, strong NR and DIR on speech recognition. Also, while moderate NR was the most preferred NR setting overall, preference for strong NR increased with SNR. No relation between RS and preference was found. However, larger PTA was related to weaker preference for inactive NR and stronger preference for strong NR for both microphone modes. Equivalent (but weaker relations between worse performance on one nonverbal measure of executive function and the HA conditions without DIR were found. For speech recognition, there were relations between HA condition, PTA, and RS, but their pattern differed from that for preference. Altogether, these results indicate that, while moderate NR works well in general, a notable proportion of HA users prefer stronger NR. Furthermore, PTA and executive functions can account for some of the variability in preference for, and speech recognition with, different binaural NR and DIR settings.

  10. Dynamic Range Across Music Genres and the Perception of Dynamic Compression in Hearing-Impaired Listeners

    Directory of Open Access Journals (Sweden)

    Martin Kirchberger

    2016-02-01

    Full Text Available Dynamic range compression serves different purposes in the music and hearing-aid industries. In the music industry, it is used to make music louder and more attractive to normal-hearing listeners. In the hearing-aid industry, it is used to map the variable dynamic range of acoustic signals to the reduced dynamic range of hearing-impaired listeners. Hence, hearing-aided listeners will typically receive a dual dose of compression when listening to recorded music. The present study involved an acoustic analysis of dynamic range across a cross section of recorded music as well as a perceptual study comparing the efficacy of different compression schemes. The acoustic analysis revealed that the dynamic range of samples from popular genres, such as rock or rap, was generally smaller than the dynamic range of samples from classical genres, such as opera and orchestra. By comparison, the dynamic range of speech, based on recordings of monologues in quiet, was larger than the dynamic range of all music genres tested. The perceptual study compared the effect of the prescription rule NAL-NL2 with a semicompressive and a linear scheme. Music subjected to linear processing had the highest ratings for dynamics and quality, followed by the semicompressive and the NAL-NL2 setting. These findings advise against NAL-NL2 as a prescription rule for recorded music and recommend linear settings.

  11. Dynamic Range Across Music Genres and the Perception of Dynamic Compression in Hearing-Impaired Listeners

    Science.gov (United States)

    Kirchberger, Martin

    2016-01-01

    Dynamic range compression serves different purposes in the music and hearing-aid industries. In the music industry, it is used to make music louder and more attractive to normal-hearing listeners. In the hearing-aid industry, it is used to map the variable dynamic range of acoustic signals to the reduced dynamic range of hearing-impaired listeners. Hence, hearing-aided listeners will typically receive a dual dose of compression when listening to recorded music. The present study involved an acoustic analysis of dynamic range across a cross section of recorded music as well as a perceptual study comparing the efficacy of different compression schemes. The acoustic analysis revealed that the dynamic range of samples from popular genres, such as rock or rap, was generally smaller than the dynamic range of samples from classical genres, such as opera and orchestra. By comparison, the dynamic range of speech, based on recordings of monologues in quiet, was larger than the dynamic range of all music genres tested. The perceptual study compared the effect of the prescription rule NAL-NL2 with a semicompressive and a linear scheme. Music subjected to linear processing had the highest ratings for dynamics and quality, followed by the semicompressive and the NAL-NL2 setting. These findings advise against NAL-NL2 as a prescription rule for recorded music and recommend linear settings. PMID:26868955

  12. Dynamic Range Across Music Genres and the Perception of Dynamic Compression in Hearing-Impaired Listeners.

    Science.gov (United States)

    Kirchberger, Martin; Russo, Frank A

    2016-02-10

    Dynamic range compression serves different purposes in the music and hearing-aid industries. In the music industry, it is used to make music louder and more attractive to normal-hearing listeners. In the hearing-aid industry, it is used to map the variable dynamic range of acoustic signals to the reduced dynamic range of hearing-impaired listeners. Hence, hearing-aided listeners will typically receive a dual dose of compression when listening to recorded music. The present study involved an acoustic analysis of dynamic range across a cross section of recorded music as well as a perceptual study comparing the efficacy of different compression schemes. The acoustic analysis revealed that the dynamic range of samples from popular genres, such as rock or rap, was generally smaller than the dynamic range of samples from classical genres, such as opera and orchestra. By comparison, the dynamic range of speech, based on recordings of monologues in quiet, was larger than the dynamic range of all music genres tested. The perceptual study compared the effect of the prescription rule NAL-NL2 with a semicompressive and a linear scheme. Music subjected to linear processing had the highest ratings for dynamics and quality, followed by the semicompressive and the NAL-NL2 setting. These findings advise against NAL-NL2 as a prescription rule for recorded music and recommend linear settings. © The Author(s) 2016.

  13. Low empathy in deaf and hard of hearing (pre)adolescents compared to normal hearing controls.

    Science.gov (United States)

    Netten, Anouk P; Rieffe, Carolien; Theunissen, Stephanie C P M; Soede, Wim; Dirks, Evelien; Briaire, Jeroen J; Frijns, Johan H M

    2015-01-01

    The purpose of this study was to examine the level of empathy in deaf and hard of hearing (pre)adolescents compared to normal hearing controls and to define the influence of language and various hearing loss characteristics on the development of empathy. The study group (mean age 11.9 years) consisted of 122 deaf and hard of hearing children (52 children with cochlear implants and 70 children with conventional hearing aids) and 162 normal hearing children. The two groups were compared using self-reports, a parent-report and observation tasks to rate the children's level of empathy, their attendance to others' emotions, emotion recognition, and supportive behavior. Deaf and hard of hearing children reported lower levels of cognitive empathy and prosocial motivation than normal hearing children, regardless of their type of hearing device. The level of emotion recognition was equal in both groups. During observations, deaf and hard of hearing children showed more attention to the emotion evoking events but less supportive behavior compared to their normal hearing peers. Deaf and hard of hearing children attending mainstream education or using oral language show higher levels of cognitive empathy and prosocial motivation than deaf and hard of hearing children who use sign (supported) language or attend special education. However, they are still outperformed by normal hearing children. Deaf and hard of hearing children, especially those in special education, show lower levels of empathy than normal hearing children, which can have consequences for initiating and maintaining relationships.

  14. Enhancing Auditory Selective Attention Using a Visually Guided Hearing Aid

    Science.gov (United States)

    Kidd, Gerald, Jr.

    2017-01-01

    Purpose: Listeners with hearing loss, as well as many listeners with clinically normal hearing, often experience great difficulty segregating talkers in a multiple-talker sound field and selectively attending to the desired "target" talker while ignoring the speech from unwanted "masker" talkers and other sources of sound. This…

  15. Comparison of Speech Perception in Background Noise with Acceptance of Background Noise in Aided and Unaided Conditions.

    Science.gov (United States)

    Nabelek, Anna K.; Tampas, Joanna W.; Burchfield, Samuel B.

    2004-01-01

    l, speech perception in noiseBackground noise is a significant factor influencing hearing-aid satisfaction and is a major reason for rejection of hearing aids. Attempts have been made by previous researchers to relate the use of hearing aids to speech perception in noise (SPIN), with an expectation of improved speech perception followed by an…

  16. The effect of extending high-frequency bandwidth on the acceptable noise level (ANL) of hearing-impaired listeners.

    Science.gov (United States)

    Johnson, Earl; Ricketts, Todd; Hornsby, Benjamin

    2009-01-01

    This study examined the effects of extending high-frequency bandwidth, for both a speech signal and a background noise, on the acceptable signal-to-noise ratio (SNR) of listeners with mild sensorineural hearing loss through utilization of the Acceptable Noise Level (ANL) procedure. In addition to extending high-frequency bandwidth, the effects of reverberation time and background noise type and shape were also examined. The study results showed a significant increase in the mean ANL (i.e. participants requested a better SNR for an acceptable listening situation) when high-frequency bandwidth was extended from 3 to 9 kHz and from 6 to 9 kHz. No change in the ANL of study participants was observed as a result of isolated modification to reverberation time or background noise stimulus. An interaction effect, however, of reverberation time and background noise stimulus was demonstrated. These findings may have implications for future design of hearing aid memory programs for listening to speech in the presence of broadband background noise.

  17. Hearing in middle age: a population snapshot of 40–69 year olds in the UK

    Science.gov (United States)

    Dawes, Piers; Fortnum, Heather; Moore, David R.; Emsley, Richard; Norman, Paul; Cruickshanks, Karen; Davis, Adrian; Edmondson-Jones, Mark; McCormack, Abby; Lutman, Mark; Munro, Kevin

    2014-01-01

    Objective To report population-based prevalence of hearing impairment based on speech recognition in noise testing in a large and inclusive sample of UK adults aged 40 to 69 years. The present study is the first to report such data. Prevalence of tinnitus and use of hearing aids is also reported. Design The research was conducted using the UK Biobank resource. The better-ear unaided speech reception threshold was measured adaptively using the Digit Triplet Test (n = 164,770). Self-report data on tinnitus, hearing aid use, noise exposure as well as demographic variables were collected. Results Overall, 10.7% of adults (95%CI 10.5–10.9%) had significant hearing impairment. Prevalence of tinnitus was 16.9% (95%CI 16.6–17.1%) and hearing aid use was 2.0% (95%CI 1.9–2.1%). Odds of hearing impairment increased with age, with a history of work- and music-related noise exposure, for lower socioeconomic background and for ethnic minority backgrounds. Males were at no higher risk of hearing impairment than females. Conclusion Around 1 in 10 adults aged 40 to 69 years have substantial hearing impairment. The reasons for excess risk of hearing impairment particularly for those from low socioeconomic and ethnic minority backgrounds require identification, as this represents a serious health inequality. The underutilization of hearing aids has altered little since the 1980s, and is a major cause for concern. PMID:24518430

  18. Obtaining Data on Hearing Experience Through Self-tracking

    DEFF Research Database (Denmark)

    Johansen, Benjamin; Petersen, Michael Kai; Larsen, Jakob Eg

    2016-01-01

    This position paper argues that self-tracking data can enrich a pre-fitting process of hearing aids. It is argued that hearing loss consist of three parts. Tonal sensitivity, signal to-noise-sensitivity, and cognitive capabilities which can be assessed by using smartphones. Combining this with co...

  19. Objective Prediction of Hearing Aid Benefit Across Listener Groups Using Machine Learning: Speech Recognition Performance With Binaural Noise-Reduction Algorithms.

    Science.gov (United States)

    Schädler, Marc R; Warzybok, Anna; Kollmeier, Birger

    2018-01-01

    The simulation framework for auditory discrimination experiments (FADE) was adopted and validated to predict the individual speech-in-noise recognition performance of listeners with normal and impaired hearing with and without a given hearing-aid algorithm. FADE uses a simple automatic speech recognizer (ASR) to estimate the lowest achievable speech reception thresholds (SRTs) from simulated speech recognition experiments in an objective way, independent from any empirical reference data. Empirical data from the literature were used to evaluate the model in terms of predicted SRTs and benefits in SRT with the German matrix sentence recognition test when using eight single- and multichannel binaural noise-reduction algorithms. To allow individual predictions of SRTs in binaural conditions, the model was extended with a simple better ear approach and individualized by taking audiograms into account. In a realistic binaural cafeteria condition, FADE explained about 90% of the variance of the empirical SRTs for a group of normal-hearing listeners and predicted the corresponding benefits with a root-mean-square prediction error of 0.6 dB. This highlights the potential of the approach for the objective assessment of benefits in SRT without prior knowledge about the empirical data. The predictions for the group of listeners with impaired hearing explained 75% of the empirical variance, while the individual predictions explained less than 25%. Possibly, additional individual factors should be considered for more accurate predictions with impaired hearing. A competing talker condition clearly showed one limitation of current ASR technology, as the empirical performance with SRTs lower than -20 dB could not be predicted.

  20. Age-related hearing loss or presbycusis.

    Science.gov (United States)

    Huang, Qi; Tang, Jianguo

    2010-08-01

    Aging is a natural consequence of a society developing process. Although many adults retain good hearing as they aging, hearing loss related with age-presbycusis which can vary in severity from mild to substantial is common among elderly persons. There are a number of pathophysiological processes underlying age-related changes in the auditory system as well as in the central nervous systems. Many studies have been dedicated to the illustration of risk factors accumulating presbycusis such as heritability, environment factors, medical conditions, free radical (reactive oxygen species, ROS) and damage of mitochondrial DNA. Left untreated, presbycusis can not only lead sufferers to reduced quality of life, isolation, dependence and frustration, but also affect the healthy people around. These can be partly corrected using hearing aids, but it is not enough, more and more strategies of treatment based on the findings associating with presbycusis should be added rather than using single hearing aids. We review here the pathophysiology; heritability, susceptibility genes and other risk factors including environmental, medical, especially free radical (ROS) and damage of mitochondrial DNA; and some strategies of treatment, as well as promising rehabilitations associating with presbycusis.

  1. Auditory tests for characterizing individual hearing deficits: The BEAR test battery

    DEFF Research Database (Denmark)

    Sanchez Lopez, Raul; Fereczkowski, Michal; Bianchi, Federica

    deficits can be complex. Therefore, one aim of the BEAR project is to design a hearing test battery for classification of listeners into a small number of auditory profiles. If successful, this BEAR test battery may be refined and reduced to form the basis for improved profile-based hearing-aid fitting......BACKGROUND The Better hEAring Rehabilitation (BEAR) project seeks to develop and assess new clinically feasible strategies for individualized hearing-loss diagnosis and hearing-aid fitting. The aim is to improve current clinical practice, where the fitting process relies on the pure-tone audiogram...... protocols. METHOD Based on the reanalysis of existing auditory profiling data and on criteria of their feasibility, time efficiency, and evidence from the literature, eleven potential tests for inclusion in a clinical test battery were selected. The proposed tests were divided into six categories...

  2. Understanding low uptake of bone anchored hearing ads: A review.

    OpenAIRE

    Powell, Rachael; Wearden, Alison; Pardesi, Sophie M; Green, Kevin

    2017-01-01

    Background: Bone anchored hearing aids (Baha) improve hearing for patients for whom conventional behind-the-ear aids are problematic. However, uptake of Baha is low and it is important to understand why this is the case. Method: A narrative review was conducted. Studies examining why people accept or decline Baha and satisfaction in people with Baha were reviewed. Results: Reasons for declining Baha included limited perceived benefits, concerns about surgery, aesthetic concerns and treatment ...

  3. Evaluation of the effects of nonlinear frequency compression on speech recognition and sound quality for adults with mild to moderate hearing loss.

    Science.gov (United States)

    Picou, Erin M; Marcrum, Steven C; Ricketts, Todd A

    2015-03-01

    While potentially improving audibility for listeners with considerable high frequency hearing loss, the effects of implementing nonlinear frequency compression (NFC) for listeners with moderate high frequency hearing loss are unclear. The purpose of this study was to investigate the effects of activating NFC for listeners who are not traditionally considered candidates for this technology. Participants wore study hearing aids with NFC activated for a 3-4 week trial period. After the trial period, they were tested with NFC and with conventional processing on measures of consonant discrimination threshold in quiet, consonant recognition in quiet, sentence recognition in noise, and acceptableness of sound quality of speech and music. Seventeen adult listeners with symmetrical, mild to moderate sensorineural hearing loss participated. Better ear, high frequency pure-tone averages (4, 6, and 8 kHz) were 60 dB HL or better. Activating NFC resulted in lower (better) thresholds for discrimination of /s/, whose spectral center was 9 kHz. There were no other significant effects of NFC compared to conventional processing. These data suggest that the benefits, and detriments, of activating NFC may be limited for this population.

  4. Effects of Removing Low-Frequency Electric Information on Speech Perception with Bimodal Hearing

    Science.gov (United States)

    Fowler, Jennifer R.; Eggleston, Jessica L.; Reavis, Kelly M.; McMillan, Garnett P.; Reiss, Lina A. J.

    2016-01-01

    Purpose: The objective was to determine whether speech perception could be improved for bimodal listeners (those using a cochlear implant [CI] in one ear and hearing aid in the contralateral ear) by removing low-frequency information provided by the CI, thereby reducing acoustic-electric overlap. Method: Subjects were adult CI subjects with at…

  5. Improving speech-in-noise recognition for children with hearing loss: potential effects of language abilities, binaural summation, and head shadow.

    Science.gov (United States)

    Nittrouer, Susan; Caldwell-Tarr, Amanda; Tarr, Eric; Lowenstein, Joanna H; Rice, Caitlin; Moberly, Aaron C

    2013-08-01

    This study examined speech recognition in noise for children with hearing loss, compared it to recognition for children with normal hearing, and examined mechanisms that might explain variance in children's abilities to recognize speech in noise. Word recognition was measured in two levels of noise, both when the speech and noise were co-located in front and when the noise came separately from one side. Four mechanisms were examined as factors possibly explaining variance: vocabulary knowledge, sensitivity to phonological structure, binaural summation, and head shadow. Participants were 113 eight-year-old children. Forty-eight had normal hearing (NH) and 65 had hearing loss: 18 with hearing aids (HAs), 19 with one cochlear implant (CI), and 28 with two CIs. Phonological sensitivity explained a significant amount of between-groups variance in speech-in-noise recognition. Little evidence of binaural summation was found. Head shadow was similar in magnitude for children with NH and with CIs, regardless of whether they wore one or two CIs. Children with HAs showed reduced head shadow effects. These outcomes suggest that in order to improve speech-in-noise recognition for children with hearing loss, intervention needs to be comprehensive, focusing on both language abilities and auditory mechanisms.

  6. Aid and good governance: Examining aggregate unintended effects of aid.

    Science.gov (United States)

    Dijkstra, Geske

    2018-06-01

    Although donors generally aim to improve governance in recipient countries by various means, critics claim that the aggregate effect of large aid flows is the deterioration of governance. Aid is said to weaken domestic accountability, sustain authoritarian regimes, increase political instability, weaken government capacities, and increase corruption. Conducting a systematic search in Web of Science, this paper reviews the empirical evidence for these unintended aggregate effects of aid on the political, administrative, and judicial dimensions of good governance. It finds that the negative effects of aid on governance are much exaggerated. The aggregate effect of aid on democracy has become more positive after the Cold War, and the effect of aid on government capacity and on reducing corruption has also improved over time. Furthermore, most studies show a positive effect of aid on political stability. These findings imply that donor intentions matter: donors that are serious about their intended effects on governance are able to mitigate the possible negative unintended effects of their aid. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. The influence of non-linear frequency compression on the perception of music by adults with a moderate to sever hearing loss: subjective impressions.

    Science.gov (United States)

    Uys, Marinda; Pottas, Lidia; Vinck, Bart; van Dijk, Catherine

    2012-12-01

    To date, the main direction in frequency-lowering hearing aid studies has been in relation to speech perception abilities. With improvements in hearing aid technology, interest in musical perception as a dimension that could improve hearing aid users' quality of life has grown. The purpose of this study was to determine the influence of non-linear frequency compression (NFC) on hearing aid users' subjective impressions of listening to music. DESIGN & SAMPLE: A survey research design was implemented to elicit participants' (N=40) subjective impressions of musical stimuli with and without NFC. The use of NFC significantly improved hearing aid users' perception of the musical qualities of overall fidelity, tinniness and reverberance. Although participants preferred to listen to the loudness, fullness, crispness, naturalness and pleasantness of music with the use of NFC, these benefits were not significant. The use of NFC can increase hearing aid users' enjoyment and appreciation of music. Given that a relatively large percentage of hearing aid users express a loss of enjoyment of music, audiologists should not ignore the possible benefits of NFC, especially if one takes into account that previous research indicates speech perception benefits with this technology.

  8. The influence of non-linear frequency compression on the perception of music by adults with a moderate to severe hearing loss: Subjective impressions

    Directory of Open Access Journals (Sweden)

    Marinda Uys

    2012-12-01

    Full Text Available Objective: To date, the main direction in frequency-lowering hearing aid studies has been in relation to speech perception abilities. With improvements in hearing aid technology, interest in musical perception as a dimension that could improve hearing aid users’ quality of life has grown. The purpose of this study was to determine the influence of non-linear frequency compression (NFC on hearing aid users’ subjective impressions of listening to music. Design & sample: A survey research design was implemented to elicit participants’ (N=40 subjective impressions of musical stimuli with and without NFC. Results: The use of NFC significantly improved hearing aid users’ perception of the musical qualities of overall fidelity, tinniness and reverberance. Although participants preferred to listen to the loudness, fullness, crispness, naturalness and pleasantness of music with the use of NFC, these benefits were not significant. Conclusion: The use of NFC can increase hearing aid users’ enjoyment and appreciation of music. Given that a relatively large percentage of hearing aid users express a loss of enjoyment of music, audiologists should not ignore the possible benefits of NFC, especially if one takes into account that previous research indicates speech perception benefits with this technology.

  9. Rethinking Hearing Aid Fitting by Learning From Behavioral Patterns

    DEFF Research Database (Denmark)

    Johansen, Benjamin; Petersen, Michael Kai; Pontoppidan, Niels Henrik

    2017-01-01

    users to remotely enhance auditory focus and attenuate background noise to improve speech intelligibility. N=5, participants changed program settings and adjusted volume on their hearing instruments using their smartphones. We found that individual behavioral patterns affected the usage of the devices....... A significant difference between program usage, and weekdays versus weekends, were found. Users not only changed programs to modify aspects of directionality and noise reduction, but also continuously adjusted the volume. Rethinking hearing instruments as devices that adaptively learn behavioral patterns based...

  10. Low Empathy in Deaf and Hard of Hearing (Pre)Adolescents Compared to Normal Hearing Controls

    Science.gov (United States)

    Netten, Anouk P.; Rieffe, Carolien; Theunissen, Stephanie C. P. M.; Soede, Wim; Dirks, Evelien; Briaire, Jeroen J.; Frijns, Johan H. M.

    2015-01-01

    Objective The purpose of this study was to examine the level of empathy in deaf and hard of hearing (pre)adolescents compared to normal hearing controls and to define the influence of language and various hearing loss characteristics on the development of empathy. Methods The study group (mean age 11.9 years) consisted of 122 deaf and hard of hearing children (52 children with cochlear implants and 70 children with conventional hearing aids) and 162 normal hearing children. The two groups were compared using self-reports, a parent-report and observation tasks to rate the children’s level of empathy, their attendance to others’ emotions, emotion recognition, and supportive behavior. Results Deaf and hard of hearing children reported lower levels of cognitive empathy and prosocial motivation than normal hearing children, regardless of their type of hearing device. The level of emotion recognition was equal in both groups. During observations, deaf and hard of hearing children showed more attention to the emotion evoking events but less supportive behavior compared to their normal hearing peers. Deaf and hard of hearing children attending mainstream education or using oral language show higher levels of cognitive empathy and prosocial motivation than deaf and hard of hearing children who use sign (supported) language or attend special education. However, they are still outperformed by normal hearing children. Conclusions Deaf and hard of hearing children, especially those in special education, show lower levels of empathy than normal hearing children, which can have consequences for initiating and maintaining relationships. PMID:25906365

  11. TELEGRAM: contribution in assistive technology indication for individuals with hearing impairment.

    Science.gov (United States)

    Jacob, Regina Tangerino de Souza; Lopes, Natália Barreto Frederigue; Cruz, Aline Duarte da; Alves, Tacianne Kriscia Machado; Santos, Larissa Germiniani Dos; Angelo, Thais Corina Said de; Mondelli, Maria Fernanda Capoani Garcia; Moret, Adriane Lima Mortari

    2017-02-23

    The objective of the study was to translate and culturally adapt to Portuguese the TELEGRAM instrument and to evaluate its effectiveness in adults with hearing impairment using hearing aids. The TELEGRAM was translated into the Portuguese language, reviewed for grammatical and idiomatic equivalences (reverse translations) and linguistic and cultural adaptations. After translation, the TELEGRAM was applied to 20 individuals with hearing impairment. A descriptive analysis of the results was performed. After the grammatical and idiomatic equivalence, the replacement of one term/item was suggested, which was modified and adapted to the Brazilian context. In general, the questions of the instrument were considered easy to understand. Among the categories assessed, individuals with hearing loss had greater difficulty using the telephone and in activities such as attending church gatherings, parties, or in situations of noisy environments, distance and reverberation. The TELEGRAM translated into Brazilian Portuguese proved to be an easily applicable tool in population studies and effective to assess which are the main situations where individuals with hearing impairment have greater difficulty in communication, reinforcing the importance of hearing rehabilitation and assistive technology to minimize these difficulties.

  12. Hearing Loss Is Negatively Related to Episodic and Semantic Long-Term Memory but Not to Short-Term Memory

    Science.gov (United States)

    Ronnberg, Jerker; Danielsson, Henrik; Rudner, Mary; Arlinger, Stig; Sternang, Ola; Wahlin, Ake; Nilsson, Lars-Goran

    2011-01-01

    Purpose: To test the relationship between degree of hearing loss and different memory systems in hearing aid users. Method: Structural equation modeling (SEM) was used to study the relationship between auditory and visual acuity and different cognitive and memory functions in an age-hetereogenous subsample of 160 hearing aid users without…

  13. Over-the-Counter Hearing Aids: A Lost Decade for Change

    Directory of Open Access Journals (Sweden)

    Zoe Yee Ting Chan

    2015-01-01

    Full Text Available Background. Hearing aids sold directly to consumers in retail stores or through the internet, without individual prescription by audiological professionals, are termed over-the-counter (OTC devices. This study aimed to determine whether there was any change in the electroacoustic characteristics of OTC devices compared to research carried out a decade earlier. The previous results indicated that most OTC devices were low-frequency-emphasis devices and were unsuitable for elderly people with presbycusis, who were likely to be the major consumers of these products. Methods. Ten OTC devices were selected and their electroacoustic performance was measured. Appropriate clients for the OTC devices were derived, using four linear prescription formulae, and OTC suitability for elderly persons with presbycusis was investigated. Results. OTC electroacoustic characteristics were similar to those in the earlier study. Most OTC devices were not acoustically appropriate for potential consumers with presbycusis. Although several of the devices could match prescriptive targets for individuals with presbycusis, their poor electroacoustic performance—including ineffective volume control function, high equivalent input noise, and irregular frequency response—may override their potential benefit. Conclusion. The low-cost OTC devices were generally not suitable for the main consumers of these products, and there has been little improvement in the appropriateness of these devices over the past decade.

  14. Over-the-Counter Hearing Aids: A Lost Decade for Change

    Science.gov (United States)

    Chan, Zoe Yee Ting; McPherson, Bradley

    2015-01-01

    Background. Hearing aids sold directly to consumers in retail stores or through the internet, without individual prescription by audiological professionals, are termed over-the-counter (OTC) devices. This study aimed to determine whether there was any change in the electroacoustic characteristics of OTC devices compared to research carried out a decade earlier. The previous results indicated that most OTC devices were low-frequency-emphasis devices and were unsuitable for elderly people with presbycusis, who were likely to be the major consumers of these products. Methods. Ten OTC devices were selected and their electroacoustic performance was measured. Appropriate clients for the OTC devices were derived, using four linear prescription formulae, and OTC suitability for elderly persons with presbycusis was investigated. Results. OTC electroacoustic characteristics were similar to those in the earlier study. Most OTC devices were not acoustically appropriate for potential consumers with presbycusis. Although several of the devices could match prescriptive targets for individuals with presbycusis, their poor electroacoustic performance—including ineffective volume control function, high equivalent input noise, and irregular frequency response—may override their potential benefit. Conclusion. The low-cost OTC devices were generally not suitable for the main consumers of these products, and there has been little improvement in the appropriateness of these devices over the past decade. PMID:26557701

  15. A Review of Hearing Loss in Cleft Palate Patients

    Directory of Open Access Journals (Sweden)

    Bilal Gani

    2012-01-01

    Full Text Available Background. Cleft palate is associated with recurrent otitis media with effusion and hearing loss. This study analysed the way these patients’ hearing is managed in Alder Hey Children’s Hospital. Method. A retrospective audit was carried out on cleft palate patients in Alder Hey Children’s Hospital. Audiology assessment and treatment options were reviewed. Comparisons were made between the use of ventilation tubes (VTs and hearing aids (HAs. The types of cleft, types of hearing loss, and the management output of the audiology regions were also reviewed. Results. The audiology assessments of 254 patients were examined. The incidence of VT insertion in this group of patients was 18.9%. The hearing aid incidence rate was 10.1%. The VT-related complication rate was 25.5% and the HA related complication rate was 9.1%. Conclusion. The data demonstrates that both treatments are viable, and a new protocol which combines the short term benefit of VT insertion with the lower complication rate of HA is required.

  16. Functional and social results of osseointegrated hearing aids

    Directory of Open Access Journals (Sweden)

    Inmaculada MORENO-ALARCÓN

    2017-06-01

    Full Text Available Introduction and objective: Osseointegrated implants are nowadays a good therapeutic option for patients suffering from transmission or mixed hearing loss. The aims of this study are both to assess audiology benefits for patients with osseointegrated implants and quantify the change in their quality of life. Method: The study included 10 patients who were implanted in our hospital between March 2013 and September 2014. The instrument used to quantify their quality of life was the Glasgow Benefit Inventory (GBI and a questionnaire including three questions: use of implant, postoperative pain and whether they would recommend the operation to other patients. Audiology assessment was performed through tone audiometry and free field speech audiometric testing. Results: The average total benefit score with the Glasgow Benefit Inventory was +58, and the general, social and physical scores were +75, +18 and +29, respectively. The improvement with the implant regarding free-field tonal audiometry at the frequencies of 500, 1000 and 2000 Hz was found to be statistically significant, as was the difference between verbal audiometry before and after implantation. Discussion: Improvements in surgical technique for osseointegrated implants, at present minimally invasive, foregrounds the assessment of functional and social aspects as a measure of their effectiveness. Conclusions: The use of the osseointegrated implant is related to an important improvement in the audiological level, especially in patients with conductive or mixed hearing loss, together with a great change in the quality of life of implanted patients.

  17. Hearing loss in children in Østfold county 2000-09.

    Science.gov (United States)

    Nelson, Siri; Andersen, Ronny; Anderssen, Sven-Harald

    2015-01-27

    The Directorate of Health recommends hearing screening of all neonates with the aid of otoacoustic emissions (OAE). The goal is to achieve initiation of treatment before the child is six months old. Congenital hearing loss occurs in 1-3 per 1,000 newborns, and the purpose of this study was to identify the prevalence in a large Norwegian dataset. During the period 1 January 2000-31 December 2009, all children who were born in Østfold county, 29,485 neonates in total, were offered hearing screening with the aid of otoacoustic emissions. Those children in whom no emissions were detected were referred to the hearing centre. The dataset also includes children born during the same period who had normal emissions during their neonatal period, but later were diagnosed with hearing loss. The follow-up period of these children lasted until 31 December 2013. Altogether 568 children were referred to the hearing centre after screening. Of these, 73 children underwent brainstem response audiometry under anaesthesia, and 31 (0.11%) were diagnosed with hearing loss through absence of emissions at birth. Eleven (35%) of these received their diagnosis before the age of six months. The median age of diagnosis decreased from 13 (7-74) to 6 (3-23) months, while their number increased from nine to 22 from 2000-04 to 2005-09. Hearing loss after normal otoacoustic emissions at the neonatal stage was diagnosed in ten children (0.03%) and the median age of diagnosis among these was 36 (18-86) months. After the introduction of automated auditory brainstem response audiometry (AABR) during sleep, the use of auditory brainstem response audiometry (ABR) under narcosis fell by half. The prevalence of hearing loss is equal to other Norwegian and international figures. The age of diagnosis decreased during the period. Otoacoustic emissions appear to be an effective screening method in paediatric wards. The use of automated auditory brainstem response audiometry reduces the need for testing under

  18. Speak on time! Effects of a musical rhythmic training on children with hearing loss.

    Science.gov (United States)

    Hidalgo, Céline; Falk, Simone; Schön, Daniele

    2017-08-01

    This study investigates temporal adaptation in speech interaction in children with normal hearing and in children with cochlear implants (CIs) and/or hearing aids (HAs). We also address the question of whether musical rhythmic training can improve these skills in children with hearing loss (HL). Children named pictures presented on the screen in alternation with a virtual partner. Alternation rate (fast or slow) and the temporal predictability (match vs mismatch of stress occurrences) were manipulated. One group of children with normal hearing (NH) and one with HL were tested. The latter group was tested twice: once after 30 min of speech therapy and once after 30 min of musical rhythmic training. Both groups of children (NH and with HL) can adjust their speech production to the rate of alternation of the virtual partner. Moreover, while children with normal hearing benefit from the temporal regularity of stress occurrences, children with HL become sensitive to this manipulation only after rhythmic training. Rhythmic training may help children with HL to structure the temporal flow of their verbal interactions. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. The performance of an automatic acoustic-based program classifier compared to hearing aid users' manual selection of listening programs.

    Science.gov (United States)

    Searchfield, Grant D; Linford, Tania; Kobayashi, Kei; Crowhen, David; Latzel, Matthias

    2018-03-01

    To compare preference for and performance of manually selected programmes to an automatic sound classifier, the Phonak AutoSense OS. A single blind repeated measures study. Participants were fit with Phonak Virto V90 ITE aids; preferences for different listening programmes were compared across four different sound scenarios (speech in: quiet, noise, loud noise and a car). Following a 4-week trial preferences were reassessed and the users preferred programme was compared to the automatic classifier for sound quality and hearing in noise (HINT test) using a 12 loudspeaker array. Twenty-five participants with symmetrical moderate-severe sensorineural hearing loss. Participant preferences of manual programme for scenarios varied considerably between and within sessions. A HINT Speech Reception Threshold (SRT) advantage was observed for the automatic classifier over participant's manual selection for speech in quiet, loud noise and car noise. Sound quality ratings were similar for both manual and automatic selections. The use of a sound classifier is a viable alternative to manual programme selection.

  20. Adaptive parametric model order reduction technique for optimization of vibro-acoustic models: Application to hearing aid design

    Science.gov (United States)

    Creixell-Mediante, Ester; Jensen, Jakob S.; Naets, Frank; Brunskog, Jonas; Larsen, Martin

    2018-06-01

    Finite Element (FE) models of complex structural-acoustic coupled systems can require a large number of degrees of freedom in order to capture their physical behaviour. This is the case in the hearing aid field, where acoustic-mechanical feedback paths are a key factor in the overall system performance and modelling them accurately requires a precise description of the strong interaction between the light-weight parts and the internal and surrounding air over a wide frequency range. Parametric optimization of the FE model can be used to reduce the vibroacoustic feedback in a device during the design phase; however, it requires solving the model iteratively for multiple frequencies at different parameter values, which becomes highly time consuming when the system is large. Parametric Model Order Reduction (pMOR) techniques aim at reducing the computational cost associated with each analysis by projecting the full system into a reduced space. A drawback of most of the existing techniques is that the vector basis of the reduced space is built at an offline phase where the full system must be solved for a large sample of parameter values, which can also become highly time consuming. In this work, we present an adaptive pMOR technique where the construction of the projection basis is embedded in the optimization process and requires fewer full system analyses, while the accuracy of the reduced system is monitored by a cheap error indicator. The performance of the proposed method is evaluated for a 4-parameter optimization of a frequency response for a hearing aid model, evaluated at 300 frequencies, where the objective function evaluations become more than one order of magnitude faster than for the full system.

  1. The effect of music on auditory perception in cochlear-implant users and normal-hearing listeners

    NARCIS (Netherlands)

    Fuller, Christina Diechina

    2016-01-01

    Cochlear implants (CIs) are auditory prostheses for severely deaf people that do not benefit from conventional hearing aids. Speech perception is reasonably good with CIs; other signals such as music perception are challenging. First, the perception of music and music related perception in CI users

  2. Hearing devices for children with unilateral hearing loss: Patient- and parent-reported perspectives.

    Science.gov (United States)

    Purcell, Patricia L; Jones-Goodrich, Rose; Wisneski, Meghan; Edwards, Todd C; Sie, Kathleen C Y

    2016-11-01

    Management of children with unilateral hearing loss is not standardized. The primary goal of this study was to elicit patient- and parent-reported perspectives regarding usage of hearing devices in pediatric UHL and to suggest a basic algorithmic approach to management. Our tertiary care center recruited families of youth ages 5-19 years with unilateral hearing loss from January 2014 through October 2015. Parents of all youths completed a 36-item survey, and some youth ages 11-19 years participated in hour-long interviews. We assessed patterns of hearing device usage among participants, and performed qualitative data analysis to understand factors considered by youths when deciding whether or not to use a hearing device. Survey information was collected for 50 patients. Distribution of hearing loss severity in affected ear was mild 14%, moderate 26%, severe 22%, and profound 38%. The majority of children had sensorineural hearing loss (57%), followed by mixed (32%), and then conductive (11%). 34 children (68%) had tried a hearing device; 20 continued to use the device. Retention rates were similar among children with different degrees of hearing loss: mild 66%, moderate 50%, severe 60%, profound 64%. Sixteen children tried a wireless contralateral routing of signal (CROS) device, and 15 tried a behind-the-ear (BTE) hearing aid. Retention rates for CROS and BTE devices were 69% and 47%, respectively. The most common reason for cessation of use was discomfort, followed by lack of benefit. A majority of children with unilateral hearing loss who tried a hearing device continued to use it, and retention rates were similar across all degrees of hearing loss. These findings suggest that personal hearing devices should be included in management protocols. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  3. Cantonese tone production performance of mainstream school children with hearing impairment.

    Science.gov (United States)

    Cheung, Karen K L; Lau, Ada H Y; Lam, Joffee H S; Lee, Kathy Y S

    2014-12-01

    This study investigated the Cantonese tone production ability of children with hearing impairment studying in mainstream schools. The participants were 87 Cantonese-speaking children with mild-to-profound degrees of hearing loss aged 5.92-13.58 in Hong Kong. Most of the children were fitted with hearing aids (n = 65); 17 of them had profound hearing impairment, one who had severe hearing loss had cochlear implantation, and four who had mild hearing loss were without any hearing device. The Hong Kong Cantonese Articulation Test was administered, and the tones produced were rated by two of the authors and a speech-language pathologist. Group effects of tones, hearing loss level, and also an interaction of the two were found to be significant. The children with profound hearing impairment performed significantly worse than most of the other children. Tone 1 was produced most accurately, whereas tone 6 productions were the poorest. No relationship was found between the number of years of mainstreaming and tone production ability. Tone production error pattern revealed that confusion patterns in tone perception coincided with those in production. Tones having a similar fundamental frequency (F0) at the onset also posed difficulty in tone production for children with hearing impairment.

  4. Objective Prediction of Hearing Aid Benefit Across Listener Groups Using Machine Learning: Speech Recognition Performance With Binaural Noise-Reduction Algorithms

    Science.gov (United States)

    Schädler, Marc R.; Warzybok, Anna; Kollmeier, Birger

    2018-01-01

    The simulation framework for auditory discrimination experiments (FADE) was adopted and validated to predict the individual speech-in-noise recognition performance of listeners with normal and impaired hearing with and without a given hearing-aid algorithm. FADE uses a simple automatic speech recognizer (ASR) to estimate the lowest achievable speech reception thresholds (SRTs) from simulated speech recognition experiments in an objective way, independent from any empirical reference data. Empirical data from the literature were used to evaluate the model in terms of predicted SRTs and benefits in SRT with the German matrix sentence recognition test when using eight single- and multichannel binaural noise-reduction algorithms. To allow individual predictions of SRTs in binaural conditions, the model was extended with a simple better ear approach and individualized by taking audiograms into account. In a realistic binaural cafeteria condition, FADE explained about 90% of the variance of the empirical SRTs for a group of normal-hearing listeners and predicted the corresponding benefits with a root-mean-square prediction error of 0.6 dB. This highlights the potential of the approach for the objective assessment of benefits in SRT without prior knowledge about the empirical data. The predictions for the group of listeners with impaired hearing explained 75% of the empirical variance, while the individual predictions explained less than 25%. Possibly, additional individual factors should be considered for more accurate predictions with impaired hearing. A competing talker condition clearly showed one limitation of current ASR technology, as the empirical performance with SRTs lower than −20 dB could not be predicted. PMID:29692200

  5. An Introduction to the Outcomes of Children with Hearing Loss Study.

    Science.gov (United States)

    Moeller, Mary Pat; Tomblin, J Bruce

    2015-01-01

    The landscape of service provision for young children with hearing loss has shifted in recent years as a result of newborn hearing screening and the early provision of interventions, including hearing technologies. It is expected that early service provision will minimize or prevent linguistic delays that typically accompany untreated permanent childhood hearing loss. The post-newborn hearing screening era has seen a resurgence of interest in empirically examining the outcomes of children with hearing loss to determine if service innovations have resulted in expected improvements in children's functioning. The Outcomes of Children with Hearing Loss (OCHL) project was among these recent research efforts, and this introductory article provides background in the form of literature review and theoretical discussion to support the goals of the study. The Outcomes of Children with Hearing Loss project was designed to examine the language and auditory outcomes of infants and preschool-age children with permanent, bilateral, mild-to-severe hearing loss, and to identify factors that moderate the relationship between hearing loss and longitudinal outcomes. The authors propose that children who are hard of hearing experience limitations in access to linguistic input, which lead to a decrease in uptake of language exposure and an overall reduction in linguistic experience. The authors explore this hypothesis in relation to three primary factors that are proposed to influence children's access to linguistic input: aided audibility, duration and consistency of hearing aid use, and characteristics of caregiver input.

  6. Hearing Preservation in Cochlear Implant Surgery

    Directory of Open Access Journals (Sweden)

    Priscila Carvalho Miranda

    2014-01-01

    Full Text Available In the past, it was thought that hearing loss patients with residual low-frequency hearing would not be good candidates for cochlear implantation since insertion was expected to induce inner ear trauma. Recent advances in electrode design and surgical techniques have made the preservation of residual low-frequency hearing achievable and desirable. The importance of preserving residual low-frequency hearing cannot be underestimated in light of the added benefit of hearing in noisy atmospheres and in music quality. The concept of electrical and acoustic stimulation involves electrically stimulating the nonfunctional, high-frequency region of the cochlea with a cochlear implant and applying a hearing aid in the low-frequency range. The principle of preserving low-frequency hearing by a “soft surgery” cochlear implantation could also be useful to the population of children who might profit from regenerative hair cell therapy in the future. Main aspects of low-frequency hearing preservation surgery are discussed in this review: its brief history, electrode design, principles and advantages of electric-acoustic stimulation, surgical technique, and further implications of this new treatment possibility for hearing impaired patients.

  7. Masker phase effects in normal-hearing and hearing-impaired listeners: evidence for peripheral compression at low signal frequencies

    DEFF Research Database (Denmark)

    Oxenham, Andrew J.; Dau, Torsten

    2004-01-01

    curvature. Results from 12 listeners with sensorineural hearing loss showed reduced masker phase effects, when compared with data from normal-hearing listeners, at both 250- and 1000-Hz signal frequencies. The effects of hearing impairment on phase-related masking differences were not well simulated...... are affected by a common underlying mechanism, presumably related to cochlear outer hair cell function. The results also suggest that normal peripheral compression remains strong even at 250 Hz....

  8. Adaptive parametric model order reduction technique for optimization of vibro-acoustic models: Application to hearing aid design

    DEFF Research Database (Denmark)

    Creixell Mediante, Ester; Jensen, Jakob Søndergaard; Naets, Frank

    2018-01-01

    Finite Element (FE) models of complex structural-acoustic coupled systems can require a large number of degrees of freedom in order to capture their physical behaviour. This is the case in the hearing aid field, where acoustic-mechanical feedback paths are a key factor in the overall system...... by projecting the full system into a reduced space. A drawback of most of the existing techniques is that the vector basis of the reduced space is built at an offline phase where the full system must be solved for a large sample of parameter values, which can also become highly time consuming. In this work, we...

  9. Six year effectiveness of a population based two tier infant hearing screening programme.

    Science.gov (United States)

    Russ, S A; Rickards, F; Poulakis, Z; Barker, M; Saunders, K; Wake, M

    2002-04-01

    To determine whether a two tier universal infant hearing screening programme (population based risk factor ascertainment and universal distraction testing) lowered median age of diagnosis of bilateral congenital hearing impairment (CHI) >40 dB HL in Victoria, Australia. Comparison of whole population birth cohorts pre and post introduction of the Victorian Infant Hearing Screening Program (VIHSP). All babies surviving the neonatal period born in Victoria in 1989 (pre-VIHSP) and 1993 (post-VIHSP) were studied. (1) Pre-1992: distraction test at 7-9 months. (2) Post-1992: infants with risk factors for CHI referred for auditory brain stem evoked response (ABR) assessment; all others screened by modified distraction test at 7-9 months. Of the 1989 cohort (n = 63 454), 1.65/1000 were fitted with hearing aids for CHI by end 1995, compared with 2.09/1000 of the 1993 cohort (n = 64 116) by end 1999. Of these, 79 cases from the 1989 cohort (1.24/1000) and 72 cases from the 1993 cohort (1.12/1000) had CHI >40 dB HL. Median age at diagnosis of CHI >40 dB HL for the 1989 birth cohort was 20.3 months, and for the 1993 cohort was 14.2 months. Median age at diagnosis fell significantly for severe CHI but not for moderate or profound CHI. Significantly more babies with CHI >40 dB HL were diagnosed by 6 months of age in 1993 than in 1989 (21.7% v 6.3%). Compared to the six years pre-VIHSP, numbers aided by six months were consistently higher in the six years post-VIHSP (1.05 per 100 000 births versus 13.4 per 100 000 births per year). VIHSP resulted in very early diagnosis for more infants and lowered median age of diagnosis of severe CHI. However, overall results were disappointing.

  10. Coarticulation in Early Vocalizations by Children with Hearing Loss: A Locus Perspective

    Science.gov (United States)

    Morrison, Helen Mccaffrey

    2012-01-01

    Locus equations derived from productions by three children with hearing loss revealed sensory and motor influences on anticipatory coarticulation. Participants who received auditory access to speech via hearing aids and cochlear implants at different ages (5-39 months) were recorded at approximately 6 and 12 months after hearing technology…

  11. Aid Effectiveness on Growth

    DEFF Research Database (Denmark)

    Doucouliagos, Hristos; Paldam, Martin

    The AEL (aid effectiveness literature) is econo¬metric studies of the macroeconomic effects of development aid. It contains about 100 papers of which 68 are reduced form estimates of theeffect of aid on growth in the recipient country. The raw data show that growth is unconnected to aid......, but the AEL has put so much structure on the data that all results possible have emerged. The present meta study considers both the best-set of the 68 papers and the all-set of 543 regressions published. Both sets have a positive average aid-growth elasticity, but it is small and insignificant: The AEL has...... betweenstudies is real. In particular, the aid-growth association is stronger for Asian countries, and the aid-growth association is shown to have been weaker in the 1970s....

  12. Emotion Understanding in Preschool Children with Mild-to-Severe Hearing Loss

    Science.gov (United States)

    Laugen, Nina J.; Jacobsen, Karl H.; Rieffe, Carolien; Wichstrøm, Lars

    2017-01-01

    Deaf and hard of hearing school-aged children are at risk for delayed development of emotion understanding; however, little is known about this during the preschool years. We compared the level of emotion understanding in a group of 35 4-5-year-old children who use hearing aids to that of 130 children with typical hearing. Moreover, we…

  13. Satisfação de pacientes protetizados em um serviço de alta complexidade Satisfaction of patients fit with a hearing aid in a high complexity clinic

    Directory of Open Access Journals (Sweden)

    Fernanda Soares Aurélio

    2012-10-01

    Full Text Available O processo de seleção e adaptação de próteses auditivas só será eficaz e terá bons resultados se o indivíduo fizer uso efetivo deste dispositivo. Para isto, é necessário que o mesmo esteja satisfeito com os resultados sentidos. OBJETIVO: Verificar a satisfação auditiva de pacientes adultos e idosos protetizados em um serviço de alta complexidade, credenciado ao Sistema Único de Saúde, e relacionar este achado com as variáveis idade, gênero, tempo de adaptação, tempo de uso diário e tipo de aparelho de amplificação sonora. MÉTODO: Estudo transversal de caráter descritivo no qual foram avaliados 60 sujeitos com utilização do questionário Satisfaction with Amplification in Daily Life, aplicado por meio de apresentação oral, em entrevista individual, pelas pesquisadoras. Este instrumento é dividido nas subescalas efeitos positivos, serviços e custos, fatores negativos e imagem pessoal. RESULTADOS: Foi evidenciado que os sujeitos encontram-se muito satisfeitos com a utilização do aparelho auditivo. Verificou-se diferença significativa ao relacionar o tempo de uso diário dos aparelhos com a satisfação global e o escore da subescala imagem pessoal. CONCLUSÃO: Constatou-se que os participantes do estudo estão muito satisfeitos com a utilização dos aparelhos auditivos, porém, satisfação não tem relação com as variáveis idade, gênero, tempo de adaptação e tipo de dispositivo. De maneira geral, os participantes com maior tempo de uso diário estão mais satisfeitos.The process of selecting and fitting hearing aid devices is only effective and only bring about good outcomes if the individual makes effective use of the device. Therefore, the individuals need to be happy with the outcome. AIM: To check the satisfaction of adults and elderly patients concerning their hearing aid in a high complex care clinic accredited by the Unified Health System, and to correlate this outcome with the variables related to

  14. Phoneme Compression: processing of the speech signal and effects on speech intelligibility in hearing-Impaired listeners

    NARCIS (Netherlands)

    A. Goedegebure (Andre)

    2005-01-01

    textabstractHearing-aid users often continue to have problems with poor speech understanding in difficult acoustical conditions. Another generally accounted problem is that certain sounds become too loud whereas other sounds are still not audible. Dynamic range compression is a signal processing

  15. Speech recognition and parent-ratings from auditory development questionnaires in children who are hard of hearing

    Science.gov (United States)

    McCreery, Ryan W.; Walker, Elizabeth A.; Spratford, Meredith; Oleson, Jacob; Bentler, Ruth; Holte, Lenore; Roush, Patricia

    2015-01-01

    Objectives Progress has been made in recent years in the provision of amplification and early intervention for children who are hard of hearing. However, children who use hearing aids (HA) may have inconsistent access to their auditory environment due to limitations in speech audibility through their HAs or limited HA use. The effects of variability in children’s auditory experience on parent-report auditory skills questionnaires and on speech recognition in quiet and in noise were examined for a large group of children who were followed as part of the Outcomes of Children with Hearing Loss study. Design Parent ratings on auditory development questionnaires and children’s speech recognition were assessed for 306 children who are hard of hearing. Children ranged in age from 12 months to 9 years of age. Three questionnaires involving parent ratings of auditory skill development and behavior were used, including the LittlEARS Auditory Questionnaire, Parents Evaluation of Oral/Aural Performance in Children Rating Scale, and an adaptation of the Speech, Spatial and Qualities of Hearing scale. Speech recognition in quiet was assessed using the Open and Closed set task, Early Speech Perception Test, Lexical Neighborhood Test, and Phonetically-balanced Kindergarten word lists. Speech recognition in noise was assessed using the Computer-Assisted Speech Perception Assessment. Children who are hard of hearing were compared to peers with normal hearing matched for age, maternal educational level and nonverbal intelligence. The effects of aided audibility, HA use and language ability on parent responses to auditory development questionnaires and on children’s speech recognition were also examined. Results Children who are hard of hearing had poorer performance than peers with normal hearing on parent ratings of auditory skills and had poorer speech recognition. Significant individual variability among children who are hard of hearing was observed. Children with greater

  16. Effects of long-term non-traumatic noise exposure on the adult central auditory system. Hearing problems without hearing loss.

    Science.gov (United States)

    Eggermont, Jos J

    2017-09-01

    It is known that hearing loss induces plastic changes in the brain, causing loudness recruitment and hyperacusis, increased spontaneous firing rates and neural synchrony, reorganizations of the cortical tonotopic maps, and tinnitus. Much less in known about the central effects of exposure to sounds that cause a temporary hearing loss, affect the ribbon synapses in the inner hair cells, and cause a loss of high-threshold auditory nerve fibers. In contrast there is a wealth of information about central effects of long-duration sound exposures at levels ≤80 dB SPL that do not even cause a temporary hearing loss. The central effects for these moderate level exposures described in this review include changes in central gain, increased spontaneous firing rates and neural synchrony, and reorganization of the cortical tonotopic map. A putative mechanism is outlined, and the effect of the acoustic environment during the recovery process is illustrated. Parallels are drawn with hearing problems in humans with long-duration exposures to occupational noise but with clinical normal hearing. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Autism and peripheral hearing loss: a systematic review.

    Science.gov (United States)

    Beers, Alison N; McBoyle, Melanie; Kakande, Emily; Dar Santos, Rachelle C; Kozak, Frederick K

    2014-01-01

    To systematically review the literature describing the relationship between autism spectrum disorder (ASD) and peripheral hearing loss including literature recommendations for audiological assessment and auditory habilitation in cases where peripheral hearing loss and ASD coexist. Published studies indexed in MEDLINE (1948-2011). The search strategy identified 595 potential studies. After a review of the titles, 115 abstracts were reviewed and 39 articles were retrieved and assessed independently by at least two authors for possible inclusion. 22 articles pertained to children with ASD and peripheral hearing loss, hearing assessment in children with ASD, audiological habilitation for children with ASD or hyper-responsiveness in children with ASD. 17 further studies were garnered from the reference section of the 22 papers. Controversy exists in the literature regarding prevalence of hearing impairment among individuals with ASD. In cases where ASD and hearing impairment co-exist, diagnosis of one condition often leads to a delay in diagnosing the other. Audiological assessment can be difficult in children with ASD and test-retest reliability of behavioural thresholds can be poor. In cases where hearing impairment exists and hearing aids or cochlear implantation are recommended, devices are often fit with special considerations for the child with ASD. Hyper-responsiveness to auditory stimuli may be displayed by individuals with ASD. Evidence or the suspicion of hyper-responsiveness may be taken into consideration when fitting amplification and planning behavioural intervention. Prevalence rates of hearing impairment among individuals with ASD continue to be debated. At present there is no conclusive evidence that children with ASD are at increased risk of peripheral hearing loss. A complete audiological assessment is recommended in all cases where ASD is suspected so as not to delay the diagnosis of hearing impairment in the event that hearing loss and ASD co

  18. Assessing Speech Intelligibility in Children with Hearing Loss: Toward Revitalizing a Valuable Clinical Tool

    Science.gov (United States)

    Ertmer, David J.

    2011-01-01

    Background: Newborn hearing screening, early intervention programs, and advancements in cochlear implant and hearing aid technology have greatly increased opportunities for children with hearing loss to become intelligible talkers. Optimizing speech intelligibility requires that progress be monitored closely. Although direct assessment of…

  19. Impact of Primary Language and Insurance on Pediatric Hearing Health Care in a Multidisciplinary Clinic.

    Science.gov (United States)

    Su, Brooke M; Park, Jason S; Chan, Dylan K

    2017-10-01

    Objective This study aims to describe the effects of primary language and insurance status on care utilization among deaf or hard-of-hearing children under active otolaryngologic and audiologic care. Study Design Cross-sectional analysis. Setting Multidisciplinary hearing loss clinic at a tertiary center. Subjects and Methods Demographics, hearing loss data, and validated survey responses were collected from 206 patients aged 0 to 19 years. Two-sided t tests and χ 2 tests were used to obtain descriptive statistics and hypothesis testing. Results Of the sample, 52.4% spoke primarily English at home. Non-English-speaking children and families were less likely to receive psychiatric counseling (12.2% vs 35.2% in the English group, P children were less likely to know the type or degree of their child's hearing loss (56.9% vs 75.4%, P = .022), and these children were older on presentation to the clinic (8.5 vs 6.5 years of age, P = .01) compared to privately insured children. Publicly insured children were less likely to receive cochlear implants ( P = .046) and reported increased difficulty obtaining hearing aids ( P = .047). While all patients reported impairment in hearing-related quality of life, publicly insured children aged 2 to 7 years were more likely to perform below minimum thresholds on measures of auditory/oral functioning. Conclusion Even when under active care, deaf or hard-of-hearing children from families who do not speak English at home or with public insurance face more difficulty obtaining educational services, cochlear implants, and hearing aids. These findings represent significant disparities in access to necessary interventions.

  20. Hearing Impairment Affects Dementia Incidence. An Analysis Based on Longitudinal Health Claims Data in Germany

    Science.gov (United States)

    Teipel, Stefan; Óvári, Attila; Kilimann, Ingo; Witt, Gabriele; Doblhammer, Gabriele

    2016-01-01

    Recent research has revealed an association between hearing impairment and dementia. The objective of this study is to determine the effect of hearing impairment on dementia incidence in a longitudinal study, and whether ear, nose, and throat (ENT) specialist care, care level, institutionalization, or depression mediates or moderates this pathway. The present study used a longitudinal sample of 154,783 persons aged 65 and older from claims data of the largest German health insurer; containing 14,602 incident dementia diagnoses between 2006 and 2010. Dementia and hearing impairment diagnoses were defined according to International Classification of Diseases, Tenth Revision, codes. We used a Kaplan Meier estimator and performed Cox proportional hazard models to explore the effect of hearing impairment on dementia incidence, controlling for ENT specialist care, care level, institutionalization, and depression. Gender, age, and comorbidities were controlled for as potential confounders. Patients with bilateral (HR = 1.43, pimpairment had higher risks of dementia incidence than patients without hearing impairment. We found no significant effect for unilateral hearing impairment and other diseases of the ear. The effect of hearing impairment was only partly mediated through ENT specialist utilization. Significant interaction between hearing impairment and specialist care, care level, and institutionalization, respectively, indicated moderating effects. We discuss possible explanations for these effects. This study underlines the importance of the association between hearing impairment and dementia. Preserving hearing ability may maintain social participation and may reduce the burden associated with dementia. The particular impact of hearing aid use should be the subject of further investigations, as it offers potential intervention on the pathway to dementia. PMID:27391486

  1. Round window stimulation for conductive and mixed hearing loss.

    Science.gov (United States)

    Dillon, Margaret T; Tubbs, Rhonda S; Adunka, Marcia C; King, English R; Hillman, Todd A; Adunka, Oliver F; Chen, Douglas A; Buchman, Craig A

    2014-10-01

    Assess surgical complications, postoperative residual hearing, and speech perception outcomes of placement of a middle ear implant on the round window in conductive and mixed hearing loss cases. Single-subject, repeated-measures design where each subject served as his or her own control. Tertiary referral medical systems. Eighteen subjects with either conductive or mixed hearing loss who could not benefit from conventional amplification were enrolled in a clinical trial investigating vibratory stimulation of the round window. The floating mass transducer (FMT) was positioned in the round window niche. Unaided residual hearing, and aided sound field thresholds and speech perception abilities were evaluated preoperatively, and at 1, 3, 6, and 10 months post-activation of the external speech processor. Six subjects experienced complications that either required further medical management or resolved on their own. There was no difference in residual bone conduction thresholds or unaided word discrimination over time. All subjects experienced a significant improvement in aided speech perception abilities as compared to preoperative performance. Subjects with conductive and mixed hearing loss with placement of the FMT in the round window niche experienced improved sound field thresholds and speech perception, without compromising residual hearing thresholds. Vibratory stimulation of the round window via a middle ear implant may be an appropriate treatment option for patients with conductive and mixed hearing loss. Additional research is needed on the preferred placement of the FMT, improvement of functional gain, and methods to limit postoperative complications and need for revision surgery.

  2. Are Experienced Hearing Aid Users Faster at Grasping the Meaning of a Sentence Than Inexperienced Users? An Eye-Tracking Study

    Directory of Open Access Journals (Sweden)

    Julia Habicht

    2016-08-01

    Full Text Available This study assessed the effects of hearing aid (HA experience on how quickly a participant can grasp the meaning of an acoustic sentence-in-noise stimulus presented together with two similar pictures that either correctly (target or incorrectly (competitor depict the meaning conveyed by the sentence. Using an eye tracker, the time taken by the participant to start fixating the target (the processing time was measured for two levels of linguistic complexity (low vs. high and three HA conditions: clinical linear amplification (National Acoustic Laboratories-Revised, single-microphone noise reduction with National Acoustic Laboratories-Revised, and linear amplification ensuring a sensation level of ≥ 15 dB up to at least 4 kHz for the speech material used here. Timed button presses to the target stimuli after the end of the sentences (offline reaction times were also collected. Groups of experienced (eHA and inexperienced (iHA HA users matched in terms of age, hearing loss, and working memory capacity took part (N = 15 each. For the offline reaction times, no effects were found. In contrast, processing times increased with linguistic complexity. Furthermore, for all HA conditions, processing times were longer (poorer for the iHA group than for the eHA group, despite comparable speech recognition performance. Taken together, these results indicate that processing times are more sensitive to speech processing-related factors than offline reaction times. Furthermore, they support the idea that HA experience positively impacts the ability to process noisy speech quickly, irrespective of the precise gain characteristics.

  3. Are Experienced Hearing Aid Users Faster at Grasping the Meaning of a Sentence Than Inexperienced Users? An Eye-Tracking Study.

    Science.gov (United States)

    Habicht, Julia; Kollmeier, Birger; Neher, Tobias

    2016-09-05

    This study assessed the effects of hearing aid (HA) experience on how quickly a participant can grasp the meaning of an acoustic sentence-in-noise stimulus presented together with two similar pictures that either correctly (target) or incorrectly (competitor) depict the meaning conveyed by the sentence. Using an eye tracker, the time taken by the participant to start fixating the target (the processing time) was measured for two levels of linguistic complexity (low vs. high) and three HA conditions: clinical linear amplification (National Acoustic Laboratories-Revised), single-microphone noise reduction with National Acoustic Laboratories-Revised, and linear amplification ensuring a sensation level of ≥ 15 dB up to at least 4 kHz for the speech material used here. Timed button presses to the target stimuli after the end of the sentences (offline reaction times) were also collected. Groups of experienced (eHA) and inexperienced (iHA) HA users matched in terms of age, hearing loss, and working memory capacity took part (N = 15 each). For the offline reaction times, no effects were found. In contrast, processing times increased with linguistic complexity. Furthermore, for all HA conditions, processing times were longer (poorer) for the iHA group than for the eHA group, despite comparable speech recognition performance. Taken together, these results indicate that processing times are more sensitive to speech processing-related factors than offline reaction times. Furthermore, they support the idea that HA experience positively impacts the ability to process noisy speech quickly, irrespective of the precise gain characteristics. © The Author(s) 2016.

  4. Limitação de atividades em idosos: estudo em novos usuários de próteses auditivas por meio do questionário APHAB Activity limitations in the elderly: a study of new hearing aid users using the APHAB questionnaire

    Directory of Open Access Journals (Sweden)

    Nayyara Glícia Calheiros Flores

    2012-03-01

    Full Text Available OBJETIVO: Avaliar limitações auditivas de idosos com perda auditiva sensorioneural de grau moderado a severo segundo variáveis escolaridade e grau da perda auditiva, por meio do questionário de auto-avaliação Abbreviate Profile of Hearing Aid Benefit (APHAB. MÉTODOS: Foi aplicado o questionário em 30 idosos antes e após três meses de uso da amplificação. A amostra foi composta por 60% mulheres e 40% homens, com média de idade de 71,6 anos. O grau de escolaridade foi distribuído em três categorias: não-alfabetizado, ensino fundamental e ensino médio. Os dados foram analisados estatisticamente. Os escores foram comparados por sub-escala, e a avaliação geral pela subtração desses escores. Além disso, foi calculada a associação entre benefício e grau de escolaridade e grau de perda auditiva. RESULTADOS: O estudo comparativo entre os escores obtidos na aplicação do questionário sem e com prótese auditiva revelou diferença nas sub-escalas Facilidade de Comunicação, Reverberação e Ruído Ambiental, com valores de pPURPOSE: To evaluate hearing limitations among elderly individuals with moderate to severe sensorineural hearing loss according to the variables educational level and degree of hearing loss, using the Abbreviated Profile of Hearing Aid Benefit self-assessment questionnaire. METHODS: The questionnaire was applied to 30 elderly subjects before and after three months of use of amplification. The sample was composed of 60% females and 40% males, with mean age of 71.6 years. Educational level was divided into three categories: illiterate, elementary school, and high school education. Data were analyzed statistically. Scores were compared by subscale and an overall assessment was conducted by subtracting these scores. Moreover, it was calculated the association between benefit and educational level and degree of hearing loss. RESULTS: The comparative study between scores obtained in the questionnaire with and

  5. Do Hearing Protectors Protect Hearing?

    Science.gov (United States)

    Groenewold, Matthew R.; Masterson, Elizabeth A.; Themann, Christa L.; Davis, Rickie R.

    2015-01-01

    Background We examined the association between self-reported hearing protection use at work and incidence of hearing shifts over a 5-year period. Methods Audiometric data from 19,911 workers were analyzed. Two hearing shift measures—OSHA standard threshold shift (OSTS) and high-frequency threshold shift (HFTS)—were used to identify incident shifts in hearing between workers’ 2005 and 2009 audiograms. Adjusted odds ratios were generated using multivariable logistic regression with multi-level modeling. Results The odds ratio for hearing shift for workers who reported never versus always wearing hearing protection was nonsignificant for OSTS (OR 1.23, 95% CI 0.92–1.64) and marginally significant for HFTS (OR 1.26, 95% CI 1.00–1.59). A significant linear trend towards increased risk of HFTS with decreased use of hearing protection was observed (P = 0.02). Conclusion The study raises concern about the effectiveness of hearing protection as a substitute for noise control to prevent noise-induced hearing loss in the workplace. Am. J. Ind. Med. 57:1001–1010, 2014. Published 2014. This article is a U.S. Government work and is in the public domain in the USA. PMID:24700499

  6. Dimensions of Deaf/Hard-of Hearing and Hearing Adolescents’ Health Literacy and Health Knowledge

    Science.gov (United States)

    Smith, Scott R.; Samar, Vincent J.

    2016-01-01

    Deaf and hard-of-hearing (D/HH) adults have lower health literacy compared to hearing adults but it is unclear if this disparity also occurs in adolescence. We used the Health Literacy Skills Instrument-Short Form (HLSI-SF), Short Form of the Test of Functional Health Literacy (S-TOFHLA), Comprehensive Heart Disease Knowledge Questionnaire (CHDKQ) and newly constructed interactive and critical health literacy survey items to quantify D/HH and hearing adolescents’ health literacy. We adapted and translated survey materials into sign language and spoken English to reduce testing bias due to variable English language skills. Participants were 187 D/HH and 94 hearing college-bound high school students. Adjusting for age, gender, race/ethnicity, school grade, and SES, D/HH adolescents demonstrated weaker general and functional health literacy and cardiovascular health knowledge than hearing adolescents on the HLSI, S-TOFHLA, and CHDKQ (all p’s<.0001). Standard health literacy or knowledge scores were associated with several interactive and critical health literacy skills (all p’s<.05). D/HH adolescents who reported greater hearing-culture identity, having hearing aids, experiencing better hearing with assistive devices, having good quality of communication with parents, and attending hearing schools at least half of the time had higher functional health literacy (all p’s<.025). Those who reported English as their best language and attending hearing schools at least half the time had higher cardiovascular health knowledge scores (all p’s< .03). Results suggest that interventions to improve D/HH adolescents’ health literacy should target their health-related conversations with their families, access to printed health information, and access to health information from other people, especially health care providers and educators. PMID:27548284

  7. Dimensions of Deaf/Hard-of-Hearing and Hearing Adolescents' Health Literacy and Health Knowledge.

    Science.gov (United States)

    Smith, Scott R; Samar, Vincent J

    2016-01-01

    Deaf and hard-of-hearing (D/HH) adults have lower health literacy compared to hearing adults, but it is unclear whether this disparity also occurs in adolescence. We used the Health Literacy Skills Instrument-Short Form (HLSI-SF), Short Form of the Test of Functional Health Literacy in Adults (S-TOFHLA), Comprehensive Heart Disease Knowledge Questionnaire (CHDKQ), and newly constructed interactive and critical health literacy survey items to quantify D/HH and hearing adolescents' health literacy. We adapted and translated survey materials into sign language and spoken English to reduce testing bias due to variable English language skills. Participants were 187 D/HH and 94 hearing college-bound high school students. When we adjusted for age, gender, race/ethnicity, school grade, and socioeconomic status, D/HH adolescents demonstrated weaker general and functional health literacy and cardiovascular health knowledge than hearing adolescents on the HLSI, S-TOFHLA, and CHDKQ (all ps < .0001). Standard health literacy or knowledge scores were associated with several interactive and critical health literacy skills (all ps < .05). D/HH adolescents who reported greater hearing-culture identity, having hearing aids, experiencing better hearing with assistive devices, having good quality of communication with parents, and attending hearing schools at least half of the time had higher functional health literacy (all ps < .025). Those who reported English as their best language and attending hearing schools at least half of the time had higher cardiovascular health knowledge scores (all ps < .03). Results suggest that interventions to improve D/HH adolescents' health literacy should target their health-related conversations with their families; access to printed health information; and access to health information from other people, especially health care providers and educators.

  8. Prosody Perception and Production in Children with Hearing Loss and Age- and Gender-Matched Controls.

    Science.gov (United States)

    Kalathottukaren, Rose Thomas; Purdy, Suzanne C; Ballard, Elaine

    2017-04-01

    Auditory development in children with hearing loss, including the perception of prosody, depends on having adequate input from cochlear implants and/or hearing aids. Lack of adequate auditory stimulation can lead to delayed speech and language development. Nevertheless, prosody perception and production in people with hearing loss have received less attention than other aspects of language. The perception of auditory information conveyed through prosody using variations in the pitch, amplitude, and duration of speech is not usually evaluated clinically. This study (1) compared prosody perception and production abilities in children with hearing loss and children with normal hearing; and (2) investigated the effect of age, hearing level, and musicality on prosody perception. Participants were 16 children with hearing loss and 16 typically developing controls matched for age and gender. Fifteen of the children with hearing loss were tested while using amplification (n = 9 hearing aids, n = 6 cochlear implants). Six receptive subtests of the Profiling Elements of Prosody in Speech-Communication (PEPS-C), the Child Paralanguage subtest of Diagnostic Analysis of Nonverbal Accuracy 2 (DANVA 2), and Contour and Interval subtests of the Montreal Battery of Evaluation of Amusia (MBEA) were used. Audio recordings of the children's reading samples were rated using a perceptual prosody rating scale by nine experienced listeners who were blinded to the children's hearing status. Thirty two children, 16 with hearing loss (mean age = 8.71 yr) and 16 age- and gender-matched typically developing children with normal hearing (mean age = 8.87 yr). Assessments were completed in one session lasting 1-2 hours in a quiet room. Test items were presented using a laptop computer through loudspeaker at a comfortable listening level. For children with hearing loss using hearing instruments, all tests were completed with hearing devices set at their everyday listening setting. All PEPS

  9. The use of research questionnaires with hearing impaired adults: online vs. paper-and-pencil administration

    Directory of Open Access Journals (Sweden)

    Thorén Elisabet

    2012-10-01

    Full Text Available Abstract Background When evaluating hearing rehabilitation, it is reasonable to use self-report questionnaires as outcome measure. Questionnaires used in audiological research are developed and validated for the paper-and-pencil format. As computer and Internet use is increasing, standardized questionnaires used in the audiological context should be evaluated to determine the viability of the online administration format. The aim of this study was to compare administration of questionnaires online versus paper- and pencil of four standardised questionnaires used in hearing research and clinic. We included the Hearing Handicap Inventory for the Elderly (HHIE, the International Outcome Inventory for Hearing Aids (IOI-HA, Satisfaction with Amplification in Daily Life (SADL, and the Hospital Anxiety and Depression Scale (HADS. Methods A cross-over design was used by randomly letting the participants complete the questionnaires either online or on paper. After 3 weeks the participants filled out the same questionnaires again but in the other format. A total of 65 hearing-aid users were recruited from a hearing clinic to participate on a voluntary basis and of these 53 completed both versions of the questionnaires. Results A significant main effect of format was found on the HHIE (p Conclusions For three of the four included questionnaires the participants’ scores remained consistent across administrations and formats. For the fourth included questionnaire (HHIE a significant difference of format with a small effect size was found. The relevance of the difference in scores between the formats depends on which context the questionnaire is used in. On balance, it is recommended that the administration format remain stable across assessment points.

  10. Discrepancy between self-assessed hearing status and measured audiometric evaluation.

    Directory of Open Access Journals (Sweden)

    So Young Kim

    Full Text Available The purpose of this study was to examine the difference between self-reported hearing status and hearing impairment assessed using conventional audiometry. The associated factors were examined when a concordance between self-reported hearing and audiometric measures was lacking.In total, 19,642 individuals ≥20 years of age who participated in the Korea National Health and Nutrition Examination Surveys conducted from 2009 through 2012 were enrolled. Pure-tone hearing threshold audiometry (PTA was measured and classified into three levels: <25 dB (normal hearing; ≥25 dB <40 dB (mild hearing impairment; and ≥40 dB (moderate-to-severe hearing impairment. The self-reported hearing loss was categorized into 3 categories. The participants were categorized into three groups: the concordance (matched between self-reported hearing loss and audiometric PTA, overestimation (higher self-reported hearing loss compared to audiometric PTA, and underestimation groups (lower self-reported hearing loss compared to audiometric PTA. The associations of age, sex, education level, stress level, anxiety/depression, tympanic membrane (TM status, hearing aid use, and tinnitus with the discrepancy between the hearing self-reported hearing loss and audiometric pure tone threshold results were analyzed using multinomial logistic regression analysis with complex sampling.Overall, 80.1%, 7.1%, and 12.8% of the participants were assigned to the concordance, overestimation, and underestimation groups, respectively. Older age (adjusted odds ratios [AORs] = 1.28 [95% confidence interval = 1.19-1.37] and 2.80 [2.62-2.99] for the overestimation and the underestimation groups, respectively, abnormal TM (2.17 [1.46-3.23] and 1.59 [1.17-2.15], and tinnitus (2.44 [2.10-2.83] and 1.61 [1.38-1.87] were positively correlated with both the overestimation and underestimation groups. Compared with specialized workers, service workers, manual workers, and the unemployed were more likely

  11. Difficulty understanding speech in noise by the hearing impaired: underlying causes and technological solutions.

    Science.gov (United States)

    Healy, Eric W; Yoho, Sarah E

    2016-08-01

    A primary complaint of hearing-impaired individuals involves poor speech understanding when background noise is present. Hearing aids and cochlear implants often allow good speech understanding in quiet backgrounds. But hearing-impaired individuals are highly noise intolerant, and existing devices are not very effective at combating background noise. As a result, speech understanding in noise is often quite poor. In accord with the significance of the problem, considerable effort has been expended toward understanding and remedying this issue. Fortunately, our understanding of the underlying issues is reasonably good. In sharp contrast, effective solutions have remained elusive. One solution that seems promising involves a single-microphone machine-learning algorithm to extract speech from background noise. Data from our group indicate that the algorithm is capable of producing vast increases in speech understanding by hearing-impaired individuals. This paper will first provide an overview of the speech-in-noise problem and outline why hearing-impaired individuals are so noise intolerant. An overview of our approach to solving this problem will follow.

  12. Factors associated with hearing loss in a normal-hearing guinea pig model of Hybrid cochlear implants.

    Science.gov (United States)

    Tanaka, Chiemi; Nguyen-Huynh, Anh; Loera, Katherine; Stark, Gemaine; Reiss, Lina

    2014-10-01

    The Hybrid cochlear implant (CI), also known as Electro-Acoustic Stimulation (EAS), is a new type of CI that preserves residual acoustic hearing and enables combined cochlear implant and hearing aid use in the same ear. However, 30-55% of patients experience acoustic hearing loss within days to months after activation, suggesting that both surgical trauma and electrical stimulation may cause hearing loss. The goals of this study were to: 1) determine the contributions of both implantation surgery and EAS to hearing loss in a normal-hearing guinea pig model; 2) determine which cochlear structural changes are associated with hearing loss after surgery and EAS. Two groups of animals were implanted (n = 6 per group), with one group receiving chronic acoustic and electric stimulation for 10 weeks, and the other group receiving no direct acoustic or electric stimulation during this time frame. A third group (n = 6) was not implanted, but received chronic acoustic stimulation. Auditory brainstem response thresholds were followed over time at 1, 2, 6, and 16 kHz. At the end of the study, the following cochlear measures were quantified: hair cells, spiral ganglion neuron density, fibrous tissue density, and stria vascularis blood vessel density; the presence or absence of ossification around the electrode entry was also noted. After surgery, implanted animals experienced a range of 0-55 dB of threshold shifts in the vicinity of the electrode at 6 and 16 kHz. The degree of hearing loss was significantly correlated with reduced stria vascularis vessel density and with the presence of ossification, but not with hair cell counts, spiral ganglion neuron density, or fibrosis area. After 10 weeks of stimulation, 67% of implanted, stimulated animals had more than 10 dB of additional threshold shift at 1 kHz, compared to 17% of implanted, non-stimulated animals and 0% of non-implanted animals. This 1-kHz hearing loss was not associated with changes in any of the cochlear measures

  13. Multicenter Clinical Trial of Vibroplasty Couplers to Treat Mixed/Conductive Hearing Loss: First Results.

    Science.gov (United States)

    Zahnert, Thomas; Löwenheim, Hubert; Beutner, Dirk; Hagen, Rudolf; Ernst, Arneborg; Pau, Hans-Wilhelm; Zehlicke, Thorsten; Kühne, Hilke; Friese, Natascha; Tropitzsch, Anke; Lüers, Jan-Christoffer; Mlynski, Robert; Todt, Ingo; Hüttenbrink, Karl-Bernd

    2016-01-01

    To evaluate the safety and effectiveness of round window (RW), oval window (OW), CliP and Bell couplers for use with an active middle ear implant. This is a multicenter, long-term, prospective trial with consecutive enrollment, involving 6 university hospitals in Germany. Bone conduction, air conduction, implant-aided warble-tone thresholds and Freiburger monosyllable word recognition scores were compared with unaided preimplantation results in 28 moderate-to-profound hearing-impaired patients after 12 months of follow-up. All patients had previously undergone failed reconstruction surgeries (up to 5 or more). In a subset of patients, additional speech tests at 12 months postoperatively were used to compare the aided with the unaided condition after implantation with the processor switched off. An established quality-of-life questionnaire for hearing aids was used to determine patient satisfaction. Postoperative bone conduction remained stable. Mean functional gain for all couplers was 37 dB HL (RW = 42 dB, OW = 35 dB, Bell = 38 dB, CliP = 27 dB). The mean postoperative Freiburger monosyllable score was 71% at 65 dB SPL. The postimplantation mean SRT50 (speech reception in quiet for 50% understanding of words in sentences) improved on average by 23 dB over unaided testing and signal-to-noise ratios also improved in all patients. The International Outcome Inventory for Hearing Aids (IOI-HA)quality-of-life questionnaire was scored very positively by all patients. A significant improvement was seen with all couplers, and patients were satisfied with the device at 12 months postoperatively. These results demonstrate that an active implant is an advantage in achieving good hearing benefit in patients with prior failed reconstruction surgery. © 2016 S. Karger AG, Basel.

  14. A multidisciplinary approach to paediatric hearing loss: programme at the centre for hearing intervention and language development, National University Hospital, Singapore.

    Science.gov (United States)

    Lim, Lynne H Y

    2008-12-01

    The objective is to describe the multidisciplinary management programme at the National University Hospital (NUH) in Singapore for children with hearing impairment (HI). Over 99.95% of babies born at NUH have hearing tested with both otoacoustic emission and automated auditory brainstem response tests by 6 weeks of age. The referral rate to Otolaryngology is 0.5%. Acquired causes of congenital HI are decreasing. Thirty percent of patients at NUH with idiopathic congenital sensorineural HI have DFNB1/ GJB6 Connexin 26 HI. CT scan or MRI imaging has a higher diagnostic yield when there is unilateral, fluctuating or non-Connexin 26 related HI. Routine electrocardiogram and Opthalmology evaluations will exclude associations of fatal cardiac rhythm anomaly and retinopathy. Other investigations are directed by history and clinical examination. There is now a very wide range of increasingly sophisticated medication, neuro-otologic external, middle and inner ear surgery, hearing aids, middle ear implants and cochlear implants available to improve hearing. A multidisciplinary team from neonatology, paediatrics, otolaryngology, audiology, auditory verbal and speech therapy, ophthalmology, radiology, and psychology working closely with the child, family and schools is needed to develop a cost-effective and comprehensive management programme for paediatric HI.

  15. HIV/AIDS among Adolescents with Hearing Impairment in Nigeria ...

    African Journals Online (AJOL)

    Toshiba

    low literacy level, cycle of poverty among people with hearing impairment ... some strategies, such as participatory approaches, deaf-friendly .... incapable of learning. ... that the greatest life challenge to any persons with disability is social.

  16. Children with Auditory Neuropathy Spectrum Disorder Fitted with Hearing Aids Applying the American Academy of Audiology Pediatric Amplification Guideline: Current Practice and Outcomes.

    Science.gov (United States)

    Walker, Elizabeth; McCreery, Ryan; Spratford, Meredith; Roush, Patricia

    2016-03-01

    Up to 15% of children with permanent hearing loss (HL) have auditory neuropathy spectrum disorder (ANSD), which involves normal outer hair cell function and disordered afferent neural activity in the auditory nerve or brainstem. Given the varying presentations of ANSD in children, there is a need for more evidence-based research on appropriate clinical interventions for this population. This study compared the speech production, speech perception, and language outcomes of children with ANSD, who are hard of hearing, to children with similar degrees of mild-to-moderately severe sensorineural hearing loss (SNHL), all of whom were fitted with bilateral hearing aids (HAs) based on the American Academy of Audiology pediatric amplification guidelines. Speech perception and communication outcomes data were gathered in a prospective accelerated longitudinal design, with entry into the study between six mo and seven yr of age. Three sites were involved in participant recruitment: Boys Town National Research Hospital, the University of North Carolina at Chapel Hill, and the University of Iowa. The sample consisted of 12 children with ANSD and 22 children with SNHL. The groups were matched based on better-ear pure-tone average, better-ear aided speech intelligibility index, gender, maternal education level, and newborn hearing screening result (i.e., pass or refer). Children and their families participated in an initial baseline visit, followed by visits twice a year for children 2 yr of age. Paired-sample t-tests were used to compare children with ANSD to children with SNHL. Paired t-tests indicated no significant differences between the ANSD and SNHL groups on language and articulation measures. Children with ANSD displayed functional speech perception skills in quiet. Although the number of participants was too small to conduct statistical analyses for speech perception testing, there appeared to be a trend in which the ANSD group performed more poorly in background noise

  17. Hearing loss in Usher syndrome type II is nonprogressive.

    Science.gov (United States)

    Reisser, Christoph F V; Kimberling, William J; Otterstedde, Christian R

    2002-12-01

    Usher syndrome is an autosomal recessive disorder characterized by sensorineural hearing loss and progressive visual loss secondary to retinitis pigmentosa. In the literature, a possible progression of the moderate to severe hearing loss in Usher syndrome type II (Usher II) is controversial. We studied the development of the hearing loss of 125 patients with a clinical diagnosis of Usher syndrome type II intraindividually and interindividually by repeatedly performing complete audiological and neuro-otologic examinations. Our data show a very characteristic slope of the hearing curve in all Usher II patients and no clinically relevant progression of the hearing loss over up to 17 years. The subjective impression of a deterioration of the communicative abilities of Usher II patients must therefore be attributed to the progressive visual loss. The patients should be reassured that changes in their hearing abilities are unlikely and should be provided with optimally fitted modern hearing aids.

  18. Other Products and Devices to Improve Hearing

    Science.gov (United States)

    ... components. In hearing aids, sound is amplified and conveyed through both the outer and middle ear and ... in the middle ear. When they receive sound waves, IMEHDs vibrate and directly move the middle ear ...

  19. Verbal and Spatial Analogical Reasoning in Deaf and Hearing Children: The Role of Grammar and Vocabulary

    Science.gov (United States)

    Edwards, Lindsey; Figueras, Berta; Mellanby, Jane; Langdon, Dawn

    2011-01-01

    The extent to which cognitive development and abilities are dependent on language remains controversial. In this study, the analogical reasoning skills of deaf and hard of hearing children are explored. Two groups of children (deaf and hard of hearing children with either cochlear implants or hearing aids and hearing children) completed tests of…

  20. Using a multi-feature paradigm to measure mismatch responses to minimal sound contrasts in children with cochlear implants and hearing aids.

    Science.gov (United States)

    Uhlén, Inger; Engström, Elisabet; Kallioinen, Petter; Nakeva von Mentzer, Cecilia; Lyxell, Björn; Sahlén, Birgitta; Lindgren, Magnus; Ors, Marianne

    2017-10-01

    Our aim was to explore whether a multi-feature paradigm (Optimum-1) for eliciting mismatch negativity (MMN) would objectively capture difficulties in perceiving small sound contrasts in children with hearing impairment (HI) listening through their hearing aids (HAs) and/or cochlear implants (CIs). Children aged 5-7 years with HAs, CIs and children with normal hearing (NH) were tested in a free-field setting using a multi-feature paradigm with deviations in pitch, intensity, gap, duration, and location. There were significant mismatch responses across all subjects that were positive (p-MMR) for the gap and pitch deviants (F(1,43) = 5.17, p = 0.028 and F(1,43) = 6.56, p = 0.014, respectively) and negative (MMN) for the duration deviant (F(1,43) = 4.74, p = 0.035). Only the intensity deviant showed a significant group interaction with MMN in the HA group and p-MMR in the CI group (F(2,43) = 3.40, p = 0.043). The p-MMR correlated negatively with age, with the strongest correlation in the NH subjects. In the CI group, the late discriminative negativity (LDN) was replaced by a late positivity with a significant group interaction for the location deviant. Children with severe HI can be assessed through their hearing device with a fast multi-feature paradigm. For further studies a multi-feature paradigm including more complex speech sounds may better capture variation in auditory processing in these children. © 2017 Scandinavian Psychological Associations and John Wiley & Sons Ltd.