WorldWideScience

Sample records for head torso arms

  1. Dissociating contributions of head and torso to spatial reference frames

    DEFF Research Database (Denmark)

    Alsmith, Adrian J T; Ferrè, Elisa R; Longo, Matthew R.

    2017-01-01

    contribution of each part to spatial judgments. Both the head and the torso contributed to judgements, though with greater contributions from the torso. A second experiment manipulating visual contrast of the torso showed that this does not reflect low-level differences in visual salience between body parts....... Our results demonstrate that spatial perspective-taking relies on a weighted combination of reference frames centred on different parts of the body....

  2. SU-F-207-03: Dosimetric Effect of the Position of Arms in Torso CT Scan with Tube Current Modulation

    International Nuclear Information System (INIS)

    Liu, H; Gao, Y; Xu, X; Zhuo, W; Wu, J

    2015-01-01

    Purpose: To evaluate the patient organ dose differences between the arms-raised and arms-lowered postures in Torso multidetector computed tomography (MDCT) scan protocols with tube current modulation (TCM). Methods: Patient CT organ doses were simulated using the Monte Carlo method with human phantoms and a validated CT scanner model. A set of adult human phantoms with arms raised and arms lowered postures were developed using advanced BREP-based mesh surface geometries. Organ doses from routine Torso scan protocols such as chest, abdomen-pelvis, and CAP scans were simulated. The organ doses differences caused by two different posutres were investigated when tube current modulation (TCM) were applied during the CT scan. Results: With TCM applied, organ doses of all the listed organs of arms-lowered posture phantom are larger than those of arms raised phantom. The dose difference for most of the organs or tissues are larger than 50%, and the skin doses difference for abdomen-pelvis scan even reaches 112.03%. This is due to the fact that the tube current for patient with arms-lowered is much higher than for the arms raised posture. Conclusion: Considering CT scan with TCM, which is commonly applied clinically, patients who could not raise their arms will receive higher radiation dose than the arms raised patient, with dose differences for some tissues such as the skin being larger than 100%. This is due to the additional tube current necessary to penetrate the arms while maintaining consistent image quality. National Nature Science Foundation of China(No.11475047)

  3. Torso and Bowing Arm Three-Dimensional Joint Kinematics of Elite Cellists: Clinical and Pedagogical Implications for Practice.

    Science.gov (United States)

    Hopper, Luke; Chan, Cliffton; Wijsman, Suzanne; Ackland, Timothy; Visentin, Peter; Alderson, Jacqueline

    2017-06-01

    Elite cello playing requires complex and refined motor control. Cellists are prone to right shoulder and thoracolumbar injuries. Research informing injury management of cellists and cello pedagogy is limited. The aims of this study were to quantify the torso, right shoulder, and elbow joint movement used by elite cellists while performing a fundamental playing task, a C major scale, under two volume conditions. An eight degrees of freedom upper limb biomechanical model was applied to 3D motion capture data of the torso, upper arm, and forearm for 31 cellists with a mean experience of 19.4 yrs (SD 9.1). Two-factor ANOVA compared the joint positions between the four cello strings and two volume conditions. Significant (ppedagogical practices.

  4. LARM PKM solutions for torso design in humanoid robots

    Science.gov (United States)

    Ceccarelli, Marco

    2014-12-01

    Human-like torso features are essential in humanoid robots. In this paper problems for design and operation of solutions for a robotic torso are discussed by referring to experiences and designs that have been developed at Laboratory of Robotics and Mechatronics (LARM) in Cassino, Italy. A new solution is presented with conceptual views as waist-trunk structure that makes a proper partition of the performance for walking and arm operations as sustained by a torso.

  5. Coordinated three-dimensional motion of the head and torso by dynamic neural networks.

    Science.gov (United States)

    Kim, J; Hemami, H

    1998-01-01

    The problem of trajectory tracking control of a three dimensional (3D) model of the human upper torso and head is considered. The torso and the head are modeled as two rigid bodies connected at one point, and the Newton-Euler method is used to derive the nonlinear differential equations that govern the motion of the system. The two-link system is driven by six pairs of muscle like actuators that possess physiologically inspired alpha like and gamma like inputs, and spindle like and Golgi tendon organ like outputs. These outputs are utilized as reflex feedback for stability and stiffness control, in a long loop feedback for the purpose of estimating the state of the system (somesthesis), and as part of the input to the controller. Ideal delays of different duration are included in the feedforward and feedback paths of the system to emulate such delays encountered in physiological systems. Dynamical neural networks are trained to learn effective control of the desired maneuvers of the system. The feasibility of the controller is demonstrated by computer simulation of the successful execution of the desired maneuvers. This work demonstrates the capabilities of neural circuits in controlling highly nonlinear systems with multidelays in their feedforward and feedback paths. The ultimate long range goal of this research is toward understanding the working of the central nervous system in controlling movement. It is an interdisciplinary effort relying on mechanics, biomechanics, neuroscience, system theory, physiology and anatomy, and its short range relevance to rehabilitation must be noted.

  6. Two-Armed, Mobile, Sensate Research Robot

    Science.gov (United States)

    Engelberger, J. F.; Roberts, W. Nelson; Ryan, David J.; Silverthorne, Andrew

    2004-01-01

    The Anthropomorphic Robotic Testbed (ART) is an experimental prototype of a partly anthropomorphic, humanoid-size, mobile robot. The basic ART design concept provides for a combination of two-armed coordination, tactility, stereoscopic vision, mobility with navigation and avoidance of obstacles, and natural-language communication, so that the ART could emulate humans in many activities. The ART could be developed into a variety of highly capable robotic assistants for general or specific applications. There is especially great potential for the development of ART-based robots as substitutes for live-in health-care aides for home-bound persons who are aged, infirm, or physically handicapped; these robots could greatly reduce the cost of home health care and extend the term of independent living. The ART is a fully autonomous and untethered system. It includes a mobile base on which is mounted an extensible torso topped by a head, shoulders, and two arms. All subsystems of the ART are powered by a rechargeable, removable battery pack. The mobile base is a differentially- driven, nonholonomic vehicle capable of a speed >1 m/s and can handle a payload >100 kg. The base can be controlled manually, in forward/backward and/or simultaneous rotational motion, by use of a joystick. Alternatively, the motion of the base can be controlled autonomously by an onboard navigational computer. By retraction or extension of the torso, the head height of the ART can be adjusted from 5 ft (1.5 m) to 6 1/2 ft (2 m), so that the arms can reach either the floor or high shelves, or some ceilings. The arms are symmetrical. Each arm (including the wrist) has a total of six rotary axes like those of the human shoulder, elbow, and wrist joints. The arms are actuated by electric motors in combination with brakes and gas-spring assists on the shoulder and elbow joints. The arms are operated under closed-loop digital control. A receptacle for an end effector is mounted on the tip of the wrist and

  7. The metabolic cost of human running: is swinging the arms worth it?

    Science.gov (United States)

    Arellano, Christopher J; Kram, Rodger

    2014-07-15

    Although the mechanical function is quite clear, there is no consensus regarding the metabolic benefit of arm swing during human running. We compared the metabolic cost of running using normal arm swing with the metabolic cost of running while restricting the arms in three different ways: (1) holding the hands with the arms behind the back in a relaxed position (BACK), (2) holding the arms across the chest (CHEST) and (3) holding the hands on top of the head (HEAD). We hypothesized that running without arm swing would demand a greater metabolic cost than running with arm swing. Indeed, when compared with running using normal arm swing, we found that net metabolic power demand was 3, 9 and 13% greater for the BACK, CHEST and HEAD conditions, respectively (all Prunning without arm swing, subjects significantly increased the peak-to-peak amplitudes of both shoulder and pelvis rotation about the vertical axis, most likely a compensatory strategy to counterbalance the rotational angular momentum of the swinging legs. In conclusion, our findings support our general hypothesis that swinging the arms reduces the metabolic cost of human running. Our findings also demonstrate that arm swing minimizes torso rotation. We infer that actively swinging the arms provides both metabolic and biomechanical benefits during human running. © 2014. Published by The Company of Biologists Ltd.

  8. The effect of patient migration in bed on torso elevation.

    Science.gov (United States)

    Wiggermann, Neal; Kotowski, Susan; Davis, Kermit; VanGilder, Catherine

    2015-01-01

    Elevating the hospital head of bed (HOB) to at least 30° is recommended practice to reduce the risk of ventilator-associated pneumonia (VAP) in mechanically ventilated patients. However, this common practice prescribes the position of the bed and not of the patient, which could be significantly different. The aim of this research was to determine the relationship between patient migration in bed and anatomic torso angle. Ten healthy participants were positioned in a hospital bed that was raised from flat to 30° and 45° HOB elevations. Prior to bed movement, participants were aligned to different locations along the length of the bed to represent different amounts of migration. A motion capture system was used to measure torso angle and migration toward the foot of the bed. The relationship between torso angle and migration was estimated by linear regression. Patient migration resulted in lower torso angles for both 30° and 45° HOB articulations. A migration of 10 cm resulted in a loss of 9.1° and 13.0° of torso angle for HOB articulations of 30° and 45°, respectively (for 30° articulations: (Equation is included in full-text article.)= -0.91, R = .96; for 45° articulations: (Equation is included in full-text article.)= -1.30, R = .98). Migration toward the foot of the bed flattens the torso. To maintain a torso angle that is likely to protect against VAP, healthcare providers need to manage both HOB angle and migration. Protocols and equipment that minimize patient migration will help support effective clinical practice. Future research on patient migration, as it relates to VAP or other outcomes, should measure patient torso angle to allow accurate translation of the results to care practice.

  9. How does arm positioning of polytraumatized patients in the initial computed tomography (CT) affect image quality and diagnostic accuracy?

    International Nuclear Information System (INIS)

    Kahn, Johannes; Grupp, Ulrich; Maurer, Martin

    2014-01-01

    Purpose: To evaluate the influence of different arm positions on abdominal image quality during initial whole-body CT (WBCT) in polytraumatized patients and to assess the risk of missing potentially life-threatening injuries due to arm artifacts. Materials and methods: Between July 2011 and February 2013, WBCT scans of 203 patients with arms in the abdominal area during initial WBCT were analyzed. Six different arms-down positions were defined: patients with both (group A)/one arm(s) (group B) down alongside the torso, patients with both (group C)/one arm(s) (group D) crossed in front of the upper abdomen, patients with both (group E)/one arm(s) (group F) crossed in front of the pelvic area. A group of 203 patients with elevated arms beside the head served as a control group. Two observers jointly evaluated image quality of different organ regions using a 4-point scale system. Follow-up examinations (CT scans and/or ultrasound) were analyzed to identify findings missed during initial WBCT due to reduced image quality. Results: Image quality for most of the organ regions analyzed was found to be significantly different among all groups (p < 0.05). Image quality was most severely degraded in group A, followed by groups E and C. Positioning with one arm up resulted in significantly better image quality than both arms down (p < 0.05). Overall, arms-up positioning showed significantly better image quality than arms-down positions (p < 0.05). In one case, liver hemorrhage missed in the initial WBCT because of arm artifacts, was revealed by follow-up CT. Conclusion: In WBCT arms-down positioning significantly degrades abdominal image quality and artifacts might even conceal potentially life-threatening injuries. If the patient's status does not allow elevation of both arms, image quality can benefit from raising at least one arm. Otherwise, arms should be placed in front of the upper abdomen instead of alongside the torso

  10. Dosimetry in a torso phantom during a mammography

    International Nuclear Information System (INIS)

    Hernandez O, M.; Duran M, H. A.; Pinedo S, A.; Salas L, M. A.; Hernandez D, V. M.; Vega C, H. R.; Rivera M, T.; Ventura M, J.

    2009-10-01

    Two dosimetric magnitudes, the absorbed dose and the kerma in air to the entrance of torso have been determined. These dosimetric magnitudes are due to the radiation that is dispersed in the mammary gland when the patient undergoes a mammography study. The kerma to the entrance of the torso and the absorbed dose by the torso was obtained in a phantom of paraffin and with thermoluminescent dosemeters of ZrO 2 . The dosemeters were placed on the surface of the torso phantom while the mammography was carried out. (author)

  11. Spacesuit Soft Upper Torso Sizing Systems

    Science.gov (United States)

    Graziosi, David; Splawn, Keith

    2011-01-01

    The passive sizing system consists of a series of low-profile pulleys attached to the front and back of the shoulder bearings on a spacesuit soft upper torso (SUT), textile cord or stainless steel cable, and a modified commercial ratchet mechanism. The cord/cable is routed through the pulleys and attached to the ratchet mechanism mounted on the front of the spacesuit within reach of the suited subject. Upon actuating the ratchet mechanism, the shoulder bearing breadth is changed, providing variable upper torso sizing. The active system consists of a series of pressurizable nastic cells embedded into the fabric layers of a spacesuit SUT. These cells are integrated to the front and back of the SUT and are connected to an air source with a variable regulator. When inflated, the nastic cells provide a change in the overall shoulder bearing breadth of the spacesuit and thus, torso sizing. The research focused on the development of a high-performance sizing and actuation system. This technology has application as a suit-sizing mechanism to allow easier suit entry and more accurate suit fit with fewer torso sizes than the existing EMU (Extravehicular Mobility Unit) suit system. This advanced SUT will support NASA s Advanced EMU Evolutionary Concept of a two-sizes-fit-all upper torso for replacement of the current EMU hard upper torso (HUT). Both the passive and nastic sizing system approaches provide astronauts with real-time upper torso sizing, which translates into a more comfortable suit, providing enhanced fit resulting in improved crewmember performance during extravehicular activity. These systems will also benefit NASA by reducing flight logistics as well as overall suit system cost. The nastic sizing system approach provides additional structural redundancy over existing SUT designs by embedding additional coated fabric and uncoated fabric layers. Two sizing systems were selected to build into a prototype SUT: one active and one passive. From manned testing, it

  12. Understanding 3D human torso shape via manifold clustering

    Science.gov (United States)

    Li, Sheng; Li, Peng; Fu, Yun

    2013-05-01

    Discovering the variations in human torso shape plays a key role in many design-oriented applications, such as suit designing. With recent advances in 3D surface imaging technologies, people can obtain 3D human torso data that provide more information than traditional measurements. However, how to find different human shapes from 3D torso data is still an open problem. In this paper, we propose to use spectral clustering approach on torso manifold to address this problem. We first represent high-dimensional torso data in a low-dimensional space using manifold learning algorithm. Then the spectral clustering method is performed to get several disjoint clusters. Experimental results show that the clusters discovered by our approach can describe the discrepancies in both genders and human shapes, and our approach achieves better performance than the compared clustering method.

  13. Are Torsos the Basis for Infants' Categorization of Cats Versus Dogs? A Reply to Vidic and Haaf (2004)

    Science.gov (United States)

    Quinn, Paul C.

    2005-01-01

    Vidic and Haaf (2004) questioned the idea that infants use head information to categorize cats as distinct from dogs (Quinn & Eimas, 1996) and argued instead that the torso region is important. However, only null results were observed in the critical test comparisons between modified and unmodified stimuli. In addition, a priori preferences for…

  14. Kinematics of a Head-Neck Model Simulating Whiplash

    Science.gov (United States)

    Colicchia, Giuseppe; Zollman, Dean; Wiesner, Hartmut; Sen, Ahmet Ilhan

    2008-01-01

    A whiplash event is a relative motion between the head and torso that occurs in rear-end automobile collisions. In particular, the large inertia of the head results in a horizontal translation relative to the thorax. This paper describes a simulation of the motion of the head and neck during a rear-end (whiplash) collision. A head-neck model that…

  15. Electron microscopic evidence for the myosin head lever arm mechanism in hydrated myosin filaments using the gas environmental chamber

    International Nuclear Information System (INIS)

    Minoda, Hiroki; Okabe, Tatsuhiro; Inayoshi, Yuhri; Miyakawa, Takuya; Miyauchi, Yumiko; Tanokura, Masaru; Katayama, Eisaku; Wakabayashi, Takeyuki; Akimoto, Tsuyoshi; Sugi, Haruo

    2011-01-01

    Research highlights: → We succeeded in recording structural changes of hydrated myosin cross-bridges. → We succeeded in position-marking the cross-bridges with site-directed antibodies. → We recorded cross-bridge movement at different regions in individual cross-bridge. → The movement was smallest at the cross-bridge-subfragment two boundary. → The results provide evidence for the cross-bridge lever arm mechanism. -- Abstract: Muscle contraction results from an attachment-detachment cycle between the myosin heads extending from myosin filaments and the sites on actin filaments. The myosin head first attaches to actin together with the products of ATP hydrolysis, performs a power stroke associated with release of hydrolysis products, and detaches from actin upon binding with new ATP. The detached myosin head then hydrolyses ATP, and performs a recovery stroke to restore its initial position. The strokes have been suggested to result from rotation of the lever arm domain around the converter domain, while the catalytic domain remains rigid. To ascertain the validity of the lever arm hypothesis in muscle, we recorded ATP-induced movement at different regions within individual myosin heads in hydrated myosin filaments, using the gas environmental chamber attached to the electron microscope. The myosin head were position-marked with gold particles using three different site-directed antibodies. The amplitude of ATP-induced movement at the actin binding site in the catalytic domain was similar to that at the boundary between the catalytic and converter domains, but was definitely larger than that at the regulatory light chain in the lever arm domain. These results are consistent with the myosin head lever arm mechanism in muscle contraction if some assumptions are made.

  16. Industrial dual arm robot manipulator for precise assembly of mechanical parts

    Science.gov (United States)

    Park, Chanhun; Kim, Doohyung; Park, Kyoungtaik; Choi, Youngjin

    2007-12-01

    A new structure of dual arm robot manipulator which consists of two industrial 6-DOF arms and one 2-DOF Torso is introduced. Each industrial 6-DOF arm is able to be used as a stand-alone industrial 6-DOF robot manipulator and as a part of dual arm manipulator at the same time. These structures help the robot maker which is willing to succeed in the emerging dual arm robot market in order to have high competition for the current industrial robot market at same time. Self-collision detection algorithm for multi-arm robot and kinematics algorithms for the developed dual arm robot manipulator which are implemented in our controller are introduced.

  17. An improved Virtual Torso phantom

    International Nuclear Information System (INIS)

    Kramer, Gary H; Crowley, Paul

    2000-01-01

    The virtual phantom that was previously designed by the Human Monitoring Laboratory had some limitations. It contained no sternum and the ribs extended all the way round the torso, whereas in reality the central part of the chest is covered with a mixture of cartilage (ribs) and bone (sternum). The ribs were located below the chest wall which added to the thickness of the chest wall. The lungs did not touch the inner surface of the chest wall along their length due to the differences in curvature between the ellipsoidal lungs and the ellipsoidal cylinder that defined the torso. As a result there was extra intervening tissue between the lungs and the chest wall. This was shown to have a noticeable effect on the simulation of low energy photons. The virtual phantom has been redesigned and comparison of measured and calculated counting efficiencies shows that it is a good representation of both of LLNL or JAERI at all photon energies measured. The redesigned virtual phantom agrees to within 11% of the torsos' counting efficiency over the energy range 17 - 240 keV. Before modification, the virtual phantom's counting efficiency was a of factor three lower at 17 keV and a factor of two lower at 20 keV; now it is within 5% at 17 keV and within 10% at 20 keV. This phantom can now be reliably used to simulate lung counting. The virtual phantom still contains no sternum and the ribs extend all the way round the torso, whereas in reality the central part of the chest is covered with cartilage (ribs) and bone (sternum). However, the above results indicate that this is not a major flaw in the design of the virtual phantom, as agreement between the Monte Carlo results and experimental data is good. (author)

  18. Predicting significant torso trauma.

    Science.gov (United States)

    Nirula, Ram; Talmor, Daniel; Brasel, Karen

    2005-07-01

    Identification of motor vehicle crash (MVC) characteristics associated with thoracoabdominal injury would advance the development of automatic crash notification systems (ACNS) by improving triage and response times. Our objective was to determine the relationships between MVC characteristics and thoracoabdominal trauma to develop a torso injury probability model. Drivers involved in crashes from 1993 to 2001 within the National Automotive Sampling System were reviewed. Relationships between torso injury and MVC characteristics were assessed using multivariate logistic regression. Receiver operating characteristic curves were used to compare the model to current ACNS models. There were a total of 56,466 drivers. Age, ejection, braking, avoidance, velocity, restraints, passenger-side impact, rollover, and vehicle weight and type were associated with injury (p < 0.05). The area under the receiver operating characteristic curve (83.9) was significantly greater than current ACNS models. We have developed a thoracoabdominal injury probability model that may improve patient triage when used with ACNS.

  19. 49 CFR 572.145 - Upper and lower torso assemblies and torso flexion test procedure.

    Science.gov (United States)

    2010-10-01

    ...) ANTHROPOMORPHIC TEST DEVICES 3-year-Old Child Crash Test Dummy, Alpha Version § 572.145 Upper and lower torso... lumbar spine and abdomen of a fully assembled dummy (drawing 210-0000) to flexion articulation between... in paragraph (c) of this section, the lumbar spine-abdomen assembly shall flex by an amount that...

  20. Segmental torso masses in adolescent idiopathic scoliosis.

    Science.gov (United States)

    Keenan, Bethany E; Izatt, Maree T; Askin, Geoffrey N; Labrom, Robert D; Pettet, Graeme J; Pearcy, Mark J; Adam, Clayton J

    2014-08-01

    Adolescent idiopathic scoliosis is the most common type of spinal deformity whose aetiology remains unclear. Studies suggest that gravitational forces in the standing position play an important role in scoliosis progression, therefore anthropometric data is required to develop biomechanical models of the deformity. Few studies have analysed the trunk by vertebral level and none have performed investigations of the scoliotic trunk. The aim of this study was to determine the centroid, thickness, volume and estimated mass, for sections of the scoliotic trunk. Existing low-dose CT scans were used to estimate vertebral level-by-level torso masses for 20 female adolescent idiopathic scoliosis patients. ImageJ processing software was used to analyse the CT images and enable estimation of the segmental torso mass corresponding to each vertebral level. The patients' mean age was 15.0 (SD 2.7) years with mean major Cobb angle of 52 (SD 5.9)° and mean patient weight of 58.2 (SD 11.6) kg. The magnitude of torso segment mass corresponding to each vertebral level increased by 150% from 0.6kg at T1 to 1.5kg at L5. Similarly, segmental thickness from T1-L5 increased inferiorly from a mean 18.5 (SD 2.2) mm at T1 to 32.8 (SD 3.4) mm at L5. The mean total trunk mass, as a percentage of total body mass, was 27.8 (SD 0.5) % which was close to values reported in previous literature. This study provides new anthropometric reference data on segmental (vertebral level-by-level) torso mass in adolescent idiopathic scoliosis patients, useful for biomechanical models of scoliosis progression and treatment. Copyright © 2014 Elsevier Ltd. All rights reserved.

  1. 49 CFR 572.165 - Upper and lower torso assemblies and torso flexion test procedure.

    Science.gov (United States)

    2010-10-01

    ...) ANTHROPOMORPHIC TEST DEVICES Hybrid III Six-Year-Old Weighted Child Test Dummy § 572.165 Upper and lower torso... determine the stiffness effects of the lumbar spine (specified in 49 CFR 572.125(a)), including cable... bushing (specified in 49 CFR 572.125(a)), nut (specified in 49 CFR 572.125(a)), spine box weighting plates...

  2. 49 CFR 572.125 - Upper and lower torso assemblies and torso flexion test procedure.

    Science.gov (United States)

    2010-10-01

    ... of the dummy, the pull cable, and the load cell as shown in Figure N5. (7) Apply a tension force in the midsagittal plane to the pull cable as shown in Figure N5 at any upper torso deflection rate... determine the stiffness effects of the lumbar spine (drawing 127-3002), including cable (drawing 127-8095...

  3. The Phonetics of Head and Body Movement in the Realization of American Sign Language Signs.

    Science.gov (United States)

    Tyrone, Martha E; Mauk, Claude E

    2016-01-01

    Because the primary articulators for sign languages are the hands, sign phonology and phonetics have focused mainly on them and treated other articulators as passive targets. However, there is abundant research on the role of nonmanual articulators in sign language grammar and prosody. The current study examines how hand and head/body movements are coordinated to realize phonetic targets. Kinematic data were collected from 5 deaf American Sign Language (ASL) signers to allow the analysis of movements of the hands, head and body during signing. In particular, we examine how the chin, forehead and torso move during the production of ASL signs at those three phonological locations. Our findings suggest that for signs with a lexical movement toward the head, the forehead and chin move to facilitate convergence with the hand. By comparison, the torso does not move to facilitate convergence with the hand for signs located at the torso. These results imply that the nonmanual articulators serve a phonetic as well as a grammatical or prosodic role in sign languages. Future models of sign phonetics and phonology should take into consideration the movements of the nonmanual articulators in the realization of signs. © 2016 S. Karger AG, Basel.

  4. Mapping of Ppd-B1, a Major Candidate Gene for Late Heading on Wild Emmer Chromosome Arm 2BS and Assessment of Its Interactions with Early Heading QTLs on 3AL.

    Science.gov (United States)

    Zhou, Wei; Wu, Shasha; Ding, Mingquan; Li, Jingjuan; Shi, Zhaobin; Wei, Wei; Guo, Jialian; Zhang, Hua; Jiang, Yurong; Rong, Junkang

    2016-01-01

    Wheat heading date is an important agronomic trait determining maturation time and yield. A set of common wheat (Triticum aestivum var. Chinese Spring; CS)-wild emmer (T. turgidum L. subsp. dicoccoides (TDIC)) chromosome arm substitution lines (CASLs) was used to identify and allocate QTLs conferring late or early spike emergence by examining heading date. Genetic loci accelerating heading were found on TDIC chromosome arms 3AL and 7BS, while loci delaying heading were located on 4AL and 2BS. To map QTLs conferring late heading on 2BS, F2 populations derived from two cross combinations of CASL2BS × CS and CASL3AL × CASL2BS were developed and each planted at two times, constituting four F2 mapping populations. Heading date varied continuously among individuals of these four populations, suggesting quantitative characteristics. A genetic map of 2BS, consisting of 23 SSR and one single-stranded conformation polymorphism (SSCP) marker(s), was constructed using these F2 populations. This map spanned a genetic length of 53.2 cM with average marker density of 2.3 cM. The photoperiod-sensitivity gene Ppd-B1 was mapped to chromosome arm 2BS as a SSCP molecular marker, and was validated as tightly linked to a major QTL governing late heading of CASL2BS in all mapping populations. A significant dominance by additive effect of Ppd-B1 with the LUX gene located on 3AL was also detected. CS had more copies of Ppd-B1 than CASL2BS, implying that increased copy number could elevate the expression of Ppd-1 in CS, also increasing expression of LUX and FT genes and causing CS to have an earlier heading date than CASL2BS in long days.

  5. Multimodal image registration of the scoliotic torso for surgical planning

    International Nuclear Information System (INIS)

    Harmouche, Rola; Cheriet, Farida; Labelle, Hubert; Dansereau, Jean

    2013-01-01

    This paper presents a method that registers MRIs acquired in prone position, with surface topography (TP) and X-ray reconstructions acquired in standing position, in order to obtain a 3D representation of a human torso incorporating the external surface, bone structures, and soft tissues. TP and X-ray data are registered using landmarks. Bone structures are used to register each MRI slice using an articulated model, and the soft tissue is confined to the volume delimited by the trunk and bone surfaces using a constrained thin-plate spline. The method is tested on 3 pre-surgical patients with scoliosis and shows a significant improvement, qualitatively and using the Dice similarity coefficient, in fitting the MRI into the standing patient model when compared to rigid and articulated model registration. The determinant of the Jacobian of the registration deformation shows higher variations in the deformation in areas closer to the surface of the torso. The novel, resulting 3D full torso model can provide a more complete representation of patient geometry to be incorporated in surgical simulators under development that aim at predicting the effect of scoliosis surgery on the external appearance of the patient’s torso

  6. Multimodal image registration of the scoliotic torso for surgical planning

    Science.gov (United States)

    2013-01-01

    Background This paper presents a method that registers MRIs acquired in prone position, with surface topography (TP) and X-ray reconstructions acquired in standing position, in order to obtain a 3D representation of a human torso incorporating the external surface, bone structures, and soft tissues. Methods TP and X-ray data are registered using landmarks. Bone structures are used to register each MRI slice using an articulated model, and the soft tissue is confined to the volume delimited by the trunk and bone surfaces using a constrained thin-plate spline. Results The method is tested on 3 pre-surgical patients with scoliosis and shows a significant improvement, qualitatively and using the Dice similarity coefficient, in fitting the MRI into the standing patient model when compared to rigid and articulated model registration. The determinant of the Jacobian of the registration deformation shows higher variations in the deformation in areas closer to the surface of the torso. Conclusions The novel, resulting 3D full torso model can provide a more complete representation of patient geometry to be incorporated in surgical simulators under development that aim at predicting the effect of scoliosis surgery on the external appearance of the patient’s torso. PMID:23289431

  7. Soft-tissue imaging with C-arm cone-beam CT using statistical reconstruction

    International Nuclear Information System (INIS)

    Wang, Adam S; Stayman, J Webster; Otake, Yoshito; Siewerdsen, Jeffrey H; Kleinszig, Gerhard; Vogt, Sebastian; Gallia, Gary L; Khanna, A Jay

    2014-01-01

    The potential for statistical image reconstruction methods such as penalized-likelihood (PL) to improve C-arm cone-beam CT (CBCT) soft-tissue visualization for intraoperative imaging over conventional filtered backprojection (FBP) is assessed in this work by making a fair comparison in relation to soft-tissue performance. A prototype mobile C-arm was used to scan anthropomorphic head and abdomen phantoms as well as a cadaveric torso at doses substantially lower than typical values in diagnostic CT, and the effects of dose reduction via tube current reduction and sparse sampling were also compared. Matched spatial resolution between PL and FBP was determined by the edge spread function of low-contrast (∼40–80 HU) spheres in the phantoms, which were representative of soft-tissue imaging tasks. PL using the non-quadratic Huber penalty was found to substantially reduce noise relative to FBP, especially at lower spatial resolution where PL provides a contrast-to-noise ratio increase up to 1.4–2.2× over FBP at 50% dose reduction across all objects. Comparison of sampling strategies indicates that soft-tissue imaging benefits from fully sampled acquisitions at dose above ∼1.7 mGy and benefits from 50% sparsity at dose below ∼1.0 mGy. Therefore, an appropriate sampling strategy along with the improved low-contrast visualization offered by statistical reconstruction demonstrates the potential for extending intraoperative C-arm CBCT to applications in soft-tissue interventions in neurosurgery as well as thoracic and abdominal surgeries by overcoming conventional tradeoffs in noise, spatial resolution, and dose. (paper)

  8. 14 CFR Appendix - Special Federal Aviation Regulation No. 109

    Science.gov (United States)

    2010-01-01

    ... allowed. (3) Thoracic Trauma. If the torso of an ATD at the forward-most seat place impacts the seat and/or adjacent structure during testing, compliance with the Thoracic Trauma Index (TTI) injury..., upper arm, chest, or head of an occupant seated next to the structure—the structure or a conservative...

  9. Estimating neuromuscular stimulation within the human torso with Taser stimulus.

    Science.gov (United States)

    Sun, Hongyu; Webster, John G

    2007-11-07

    Designers of electromuscular incapacitation devices need to know efficacy. Which areas of nerve and muscle are stimulated and are these areas adequate to cause incapacitation? This paper focuses on efficacy, which used a torso-sized finite element model with a mesh of about 5 mm. To estimate the neuromuscular regions stimulated by the Taser X26, calculations of electric current density and field strength values with 1 A inserted into the torso using the Utah 3D mesh were made. Field-times-duration values for given Taser stimulation were calculated. Then the region where the motor nerve was stimulated by the Taser was estimated by using a field-times-duration threshold from Reilly (1998 'Applied Bioelectricity: From Electrical Stimulation to Electropathology ' (New York: Springer)). Neuromuscular stimulation occurred up to about 19 cm away from the darts and included the spinal cord. The current density at the heart for dart separation less than 10 cm was smaller than for larger dart separation. Users of finite element computer models will find information for torso models and their creation, meshing and operation.

  10. Robotic arm

    Science.gov (United States)

    Kwech, Horst

    1989-04-18

    A robotic arm positionable within a nuclear vessel by access through a small diameter opening and having a mounting tube supported within the vessel and mounting a plurality of arm sections for movement lengthwise of the mounting tube as well as for movement out of a window provided in the wall of the mounting tube. An end effector, such as a grinding head or welding element, at an operating end of the robotic arm, can be located and operated within the nuclear vessel through movement derived from six different axes of motion provided by mounting and drive connections between arm sections of the robotic arm. The movements are achieved by operation of remotely-controllable servo motors, all of which are mounted at a control end of the robotic arm to be outside the nuclear vessel.

  11. Validation of stereophotogrammetry of the human torso.

    Science.gov (United States)

    Lee, Juhun; Kawale, Manas; Merchant, Fatima A; Weston, June; Fingeret, Michelle C; Ladewig, Dianne; Reece, Gregory P; Crosby, Melissa A; Beahm, Elisabeth K; Markey, Mia K

    2011-02-15

    The objective of this study was to determine if measurements of breast morphology computed from three-dimensional (3D) stereophotogrammetry are equivalent to traditional anthropometric measurements obtained directly on a subject using a tape measure. 3D torso images of 23 women ranged in age from 36 to 63 who underwent or were scheduled for breast reconstruction surgery were obtained using a 3dMD torso system (3Q Technologies Inc., Atlanta, GA). Two different types (contoured and line-of-sight distances) of a total of nine distances were computed from 3D images of each participant. Each participant was photographed twice, first without fiducial points marked (referred to as unmarked image) and second with fiducial points marked prior to imaging (referred to as marked image). Stereophotogrammetry was compared to traditional direct anthropometry, in which measurements were taken with a tape measure on participants. Three statistical analyses were used to evaluate the agreement between stereophotogrammetry and direct anthropometry. Seven out of nine distances showed excellent agreement between stereophotogrammetry and direct anthropometry (both marked and unmarked images). In addition, stereophotogrammetry from the unmarked image was equivalent to that of the marked image (both line-of-sight and contoured distances). A lower level of agreement was observed for some measures because of difficulty in localizing more vaguely defined fiducial points, such as lowest visible point of breast mound, and inability of the imaging system in capturing areas obscured by the breast, such as the inframammary fold. Stereophotogrammetry from 3D images obtained from the 3dMD torso system is effective for quantifying breast morphology. Tools for surgical planning and evaluation based on stereophotogrammetry have the potential to improve breast surgery outcomes.

  12. Robotic arm

    International Nuclear Information System (INIS)

    Kwech, H.

    1989-01-01

    A robotic arm positionable within a nuclear vessel by access through a small diameter opening and having a mounting tube supported within the vessel and mounting a plurality of arm sections for movement lengthwise of the mounting tube as well as for movement out of a window provided in the wall of the mounting tube is disclosed. An end effector, such as a grinding head or welding element, at an operating end of the robotic arm, can be located and operated within the nuclear vessel through movement derived from six different axes of motion provided by mounting and drive connections between arm sections of the robotic arm. The movements are achieved by operation of remotely-controllable servo motors, all of which are mounted at a control end of the robotic arm to be outside the nuclear vessel. 23 figs

  13. Estimation of regional cutaneous cold sensitivity by analysis of the gasping response.

    Science.gov (United States)

    Burke, W E; Mekjavić, I B

    1991-11-01

    Regional cutaneous sensitivity to cooling was assessed in males by separately immersing four discrete skin regions in cold water (15 degrees C) during head-out immersion. The response measured was gasping at the onset of immersion; the gasping response appears to be the result of a nonthermoregulatory neurogenic drive from cutaneous cold receptors. Subjects of similar body proportions wore a neoprene "dry" suit modified to allow exposure to the water of either the arms, upper torso, lower torso, or legs, while keeping the unexposed skin regions thermoneutral. Each subject was immersed to the sternal notch in all four conditions of partial exposure plus one condition of whole body exposure. The five cold water conditions were matched by control immersions in lukewarm (34 degrees C) water, and trials were randomized. The magnitude of the gasping response was determined by mouth occlusion pressure (P0.1). For each subject, P0.1 values for the 1st min of immersion were integrated, and control trial values, although minimal, were subtracted from their cold water counterpart to account for any gasping due to the experimental design. Results were averaged and showed that the highest P0.1 values were elicited from whole body exposure, followed in descending order by exposures of the upper torso, legs, lower torso, and arms. Correction of the P0.1 response for differences in exposed surface area (A) and cooling stimulus (delta T) between regions gave a cold sensitivity index [CSI, P0.1/(A.delta T)] for each region and showed that the index for the upper torso was significantly higher than that for the arms or legs; no significant difference was observed between the indexes for the upper and lower torso.(ABSTRACT TRUNCATED AT 250 WORDS)

  14. Breathing, Laughing, Sneezing, Coughing: Model and Control of an Anatomically Inspired, Physically-Based Human Torso Simulation

    OpenAIRE

    DiLorenzo, Paul Carmen

    2008-01-01

    Breathing, laughing, sneezing and coughing are all important human behaviors that are generated in the torso. Yet, when these behaviors are animated, the movement of the human torso is often simplified and stylized. Recent work aiming to depict the movement of the torso has focused on pure data-driven approaches such as a skin capture of an actor using a motion capture system. Although this generates impressive results to recreate the captured motion, it does not provide control to an animato...

  15. Estimating neuromuscular stimulation within the human torso with Taser (registered) stimulus

    Energy Technology Data Exchange (ETDEWEB)

    Sun Hongyu [Department of Electrical and Computer Engineering, University of Wisconsin, Madison, WI 53706 (United States); Webster, John G [Department of Biomedical Engineering, University of Wisconsin, Madison, WI 53706 (United States)

    2007-11-07

    Designers of electromuscular incapacitation devices need to know efficacy. Which areas of nerve and muscle are stimulated and are these areas adequate to cause incapacitation? This paper focuses on efficacy, which used a torso-sized finite element model with a mesh of about 5 mm. To estimate the neuromuscular regions stimulated by the Taser (registered) X26, calculations of electric current density and field strength values with 1 A inserted into the torso using the Utah 3D mesh were made. Field-times-duration values for given Taser stimulation were calculated. Then the region where the motor nerve was stimulated by the Taser was estimated by using a field-times-duration threshold from Reilly (1998 Applied Bioelectricity: From Electrical Stimulation to Electropathology (New York: Springer)). Neuromuscular stimulation occurred up to about 19 cm away from the darts and included the spinal cord. The current density at the heart for dart separation less than 10 cm was smaller than for larger dart separation. Users of finite element computer models will find information for torso models and their creation, meshing and operation.

  16. Estimating neuromuscular stimulation within the human torso with Taser (registered) stimulus

    International Nuclear Information System (INIS)

    Sun Hongyu; Webster, John G

    2007-01-01

    Designers of electromuscular incapacitation devices need to know efficacy. Which areas of nerve and muscle are stimulated and are these areas adequate to cause incapacitation? This paper focuses on efficacy, which used a torso-sized finite element model with a mesh of about 5 mm. To estimate the neuromuscular regions stimulated by the Taser (registered) X26, calculations of electric current density and field strength values with 1 A inserted into the torso using the Utah 3D mesh were made. Field-times-duration values for given Taser stimulation were calculated. Then the region where the motor nerve was stimulated by the Taser was estimated by using a field-times-duration threshold from Reilly (1998 Applied Bioelectricity: From Electrical Stimulation to Electropathology (New York: Springer)). Neuromuscular stimulation occurred up to about 19 cm away from the darts and included the spinal cord. The current density at the heart for dart separation less than 10 cm was smaller than for larger dart separation. Users of finite element computer models will find information for torso models and their creation, meshing and operation

  17. Security and arms control

    International Nuclear Information System (INIS)

    Kolodziej, E.A.; Morgan, P.M.

    1989-01-01

    This book attempts to clarify and define selected current issues and problems related to security and arms control from an international perspective. The chapters are organized under the following headings. Conflict and the international system, Nuclear deterrence, Conventional warfare, Subconventional conflict, Arms control and crisis management

  18. Emergency department spirometric volume and base deficit delineate risk for torso injury in stable patients

    Directory of Open Access Journals (Sweden)

    Sipe Eilynn K

    2004-01-01

    Full Text Available Abstract Background We sought to determine torso injury rates and sensitivities associated with fluid-positive abdominal ultrasound, metabolic acidosis (increased base deficit and lactate, and impaired pulmonary physiology (decreased spirometric volume and PaO2/FiO2. Methods Level I trauma center prospective pilot and post-pilot study (2000–2001 of stable patients. Increased base deficit was 2.5 mmol/L in ethanol-negative and ≥ 3.0 mmol/L in ethanol-positive patients. Decreased PaO2/FiO2 was Results Of 215 patients, 66 (30.7% had a torso injury (abdominal/pelvic injury n = 35 and/or thoracic injury n = 43. Glasgow Coma Scale score was 14.8 ± 0.5 (13–15. Torso injury rates and sensitivities were: abdominal ultrasound negative and normal base deficit, lactate, PaO2/FiO2, and spirometric volume – 0.0% & 0.0%; normal base deficit and normal spirometric volume – 4.2% & 4.5%; chest/abdominal soft tissue injury – 37.8% & 47.0%; increased lactate – 39.7% & 47.0%; increased base deficit – 41.3% & 75.8%; increased base deficit and/or decreased spirometric volume – 43.8% & 95.5%; decreased PaO2/FiO2 – 48.9% & 33.3%; positive abdominal ultrasound – 62.5% & 7.6%; decreased spirometric volume – 73.4% & 71.2%; increased base deficit and decreased spirometric volume – 82.9% & 51.5%. Conclusions Trauma patients with normal base deficit and spirometric volume are unlikely to have a torso injury. Patients with increased base deficit or lactate, decreased spirometric volume, decreased PaO2/FiO2, or positive FAST have substantial risk for torso injury. Increased base deficit and/or decreased spirometric volume are highly sensitive for torso injury. Base deficit and spirometric volume values are readily available and increase or decrease the suspicion for torso injury.

  19. The Insect Neuropeptide PTTH Activates Receptor Tyrosine Kinase Torso to Initiate Metamorphosis

    DEFF Research Database (Denmark)

    Rewitz, Kim; Yamanaka, Naoki; Gilbert, Lawrence

    2009-01-01

    Holometabolous insects undergo complete metamorphosis to become sexually mature adults. Metamorphosis is initiated by brain-derived prothoracicotropic hormone (PTTH), which stimulates the production of the molting hormone ecdysone via an incompletely defined signaling pathway. Here we demonstrate...... in the prothoracic gland (PG), and its loss phenocopies the removal of PTTH. The activation of Torso by PTTH stimulates extracellular signal–regulated kinase (ERK) phosphorylation, and the loss of ERK in the PG phenocopies the loss of PTTH and Torso. We conclude that PTTH initiates metamorphosis by activation...

  20. Corrective response times in a coordinated eye-head-arm countermanding task.

    Science.gov (United States)

    Tao, Gordon; Khan, Aarlenne Z; Blohm, Gunnar

    2018-06-01

    Inhibition of motor responses has been described as a race between two competing decision processes of motor initiation and inhibition, which manifest as the reaction time (RT) and the stop signal reaction time (SSRT); in the case where motor initiation wins out over inhibition, an erroneous movement occurs that usually needs to be corrected, leading to corrective response times (CRTs). Here we used a combined eye-head-arm movement countermanding task to investigate the mechanisms governing multiple effector coordination and the timing of corrective responses. We found a high degree of correlation between effector response times for RT, SSRT, and CRT, suggesting that decision processes are strongly dependent across effectors. To gain further insight into the mechanisms underlying CRTs, we tested multiple models to describe the distribution of RTs, SSRTs, and CRTs. The best-ranked model (according to 3 information criteria) extends the LATER race model governing RTs and SSRTs, whereby a second motor initiation process triggers the corrective response (CRT) only after the inhibition process completes in an expedited fashion. Our model suggests that the neural processing underpinning a failed decision has a residual effect on subsequent actions. NEW & NOTEWORTHY Failure to inhibit erroneous movements typically results in corrective movements. For coordinated eye-head-hand movements we show that corrective movements are only initiated after the erroneous movement cancellation signal has reached a decision threshold in an accelerated fashion.

  1. Changes in the volume and circumference of the torso, leg and arm after cycling in the heat determined using 3D whole body scanners : conference paper, Lugano, Switzerland,

    NARCIS (Netherlands)

    Hein, Daanen; Vonk, L.A.

    2016-01-01

    Whole body volume changes due to sweat loss after exercise in the heat are well documented, but little is known about the relative contribution of the torso and extremities to these volume changes. It is the purpose of this study to quantify these effects. Therefore, seven healthy male subjects were

  2. Torso geometry reconstruction and body surface electrode localization using three-dimensional photography.

    Science.gov (United States)

    Perez-Alday, Erick A; Thomas, Jason A; Kabir, Muammar; Sedaghat, Golriz; Rogovoy, Nichole; van Dam, Eelco; van Dam, Peter; Woodward, William; Fuss, Cristina; Ferencik, Maros; Tereshchenko, Larisa G

    We conducted a prospective clinical study (n=14; 29% female) to assess the accuracy of a three-dimensional (3D) photography-based method of torso geometry reconstruction and body surface electrodes localization. The position of 74 body surface electrocardiographic (ECG) electrodes (diameter 5mm) was defined by two methods: 3D photography, and CT (marker diameter 2mm) or MRI (marker size 10×20mm) imaging. Bland-Altman analysis showed good agreement in X (bias -2.5 [95% limits of agreement (LoA) -19.5 to 14.3] mm), Y (bias -0.1 [95% LoA -14.1 to 13.9] mm), and Z coordinates (bias -0.8 [95% LoA -15.6 to 14.2] mm), as defined by the CT/MRI imaging, and 3D photography. The average Hausdorff distance between the two torso geometry reconstructions was 11.17±3.05mm. Thus, accurate torso geometry reconstruction using 3D photography is feasible. Body surface ECG electrodes coordinates as defined by the CT/MRI imaging, and 3D photography, are in good agreement. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Radiology trainer. Torso, internal organs and vessels. 2. ed.

    International Nuclear Information System (INIS)

    Staebler, Axel; Erlt-Wagner, Birgit

    2013-01-01

    The radiology training textbook is based on case studies of the clinical experience, including radiological imaging and differential diagnostic discussion. The scope of this volume covers the torso, internal organs and vessels. The following issues are discussed: lungs, pleura, mediastinum; heart and vascular system; upper abdomen organs; gastrointestinal tract; urogenital system.

  4. Classification of male lower torso for underwear design

    Science.gov (United States)

    Cheng, Z.; Kuzmichev, V. E.

    2017-10-01

    By means of scanning technology we have got new information about the morphology of male bodies and have redistricted the classification of men’s underwear by adopting one to consumer demands. To build the new classification in accordance with male body characteristic factors of lower torso, we make the method of underwear designing which allow to get the accurate and convenience for consumers products.

  5. Morphometric analysis of torso arterial anatomy with implications for resuscitative aortic occlusion.

    Science.gov (United States)

    Stannard, Adam; Morrison, Jonathan J; Sharon, Danny J; Eliason, Jonathan L; Rasmussen, Todd E

    2013-08-01

    Hemorrhage is a leading cause of death in military and civilian trauma. Despite the importance of the aorta as a site of hemorrhage control and resuscitative occlusion, detailed knowledge of its morphometry is lacking. The objective of this study was to characterize aortic morphometry in a trauma population, including quantification of distances as well as and diameters and definition of relevant aortic zones. Center line measures were made (Volume Viewer) from contrast computed tomography (CT) scans of male trauma patients (18-45 years). Aortic zones were defined based on branch arteries. Zone I includes left subclavian to celiac; Zone II includes celiac to caudal renal; Zone III includes caudal renal to aortic bifurcation. Zone lengths were calculated and correlated to a novel external measure of torso extent (symphysis pubis to sternal notch). Eighty-eight males (mean [SD], 28 [4] years) had CT scans for the study. The median (interquartile range) lengths (mm) of Zones I, II, and III were 210 mm (202-223 mm), 33 mm (28-38 mm), and 97 mm (91-103 mm), respectively. Median aortic diameters at the left subclavian, celiac, and lowest renal arteries were 21 mm (20-23 mm), 18 mm (16-19 mm), and 15 mm (14-16 mm), respectively, and the terminal aortic diameter was 14 mm (13-15 mm). The correlation of determination for descending aortic length (all zones) against torso extend was r = 0.454. This study provides a morphometric analysis of the aorta in a male population, demonstrating consistency of length and diameter while defining distinct axial zones. Findings suggest that center line aortic distances correlate with a simple, external measure of torso extent. Morphometric study of the aorta using CT data may facilitate the development and implementation of occlusion techniques to manage noncompressible torso, pelvic, and junctional femoral hemorrhage.

  6. Representation of heading direction in far and near head space

    NARCIS (Netherlands)

    Poljac, E.; Berg, A.V. van den

    2003-01-01

    Manipulation of objects around the head requires an accurate and stable internal representation of their locations in space, also during movements such as that of the eye or head. For far space, the representation of visual stimuli for goal-directed arm movements relies on retinal updating, if eye

  7. Head injury causation scenarios for belted, rear-seated children in frontal impacts.

    Science.gov (United States)

    Bohman, Katarina; Arbogast, Kristy B; Bostrom, Ola

    2011-02-01

    Head injuries are the most common serious injuries sustained by children in motor vehicle crashes and are of critical importance with regard to long-term disability. There is a lack of understanding of how seat belt-restrained children sustain head injuries in frontal impacts. The aim of the study was to identify the AIS2+ head injury causation scenarios for rear-seated, belt-restrained children in frontal impacts, including the set of parameters contributing to the injury. In-depth crash investigations from two National Highway Traffic Safety Administration (NHTSA) databases, the National Automotive Sampling System-Crashworthiness Data System (NASS-CDS; 1997-2008) and the Crash Injury Research and Engineering Network (CIREN; 1996-2009), were collected and analyzed in detail. Selection criteria were all frontal impacts with principal direction of force (PDOF) of 11, 12, and 1 o'clock involving rear-seated, three-point belt-restrained, with or without booster cushion, children from 3 to 13 years with an AIS2+ head injury. Cases were analyzed using the BioTab method of injury causation assessment in order to systematically analyze the injury causation scenario for each case. There were 27 cases meeting the inclusion criteria, 19 cases with MAIS2 head injuries and 8 cases with MAIS3+ head injuries, including 2 fatalities. Three major injury causation scenarios were identified, including head contact with seatback (10 cases), head contact with side interior (7 cases,) and no evidence of head contact (9 cases). Head injuries with seatback or side interior contact typically included a PDOF greater than 10 degree (similar to the Insurance Institute for Highway Safety [IIHS] and EuroNCAP offset frontal testing) and vehicle maneuvers. For seatback contact, the vehicle's movements contributed to occupant kinematics inboard the vehicle, causing a less than optimal restraint of the torso and/or torso roll out of the shoulder belt. For side interior contact, the PDOF and

  8. Image quality and localization accuracy in C-arm tomosynthesis-guided head and neck surgery

    International Nuclear Information System (INIS)

    Bachar, G.; Siewerdsen, J. H.; Daly, M. J.; Jaffray, D. A.; Irish, J. C.

    2007-01-01

    The image quality and localization accuracy for C-arm tomosynthesis and cone-beam computed tomography (CBCT) guidance of head and neck surgery were investigated. A continuum in image acquisition was explored, ranging from a single exposure (radiograph) to multiple projections acquired over a limited arc (tomosynthesis) to a full semicircular trajectory (CBCT). Experiments were performed using a prototype mobile C-arm modified to perform 3D image acquisition (a modified Siemens PowerMobil). The tradeoffs in image quality associated with the extent of the source-detector arc (θ tot ), the number of projection views, and the total imaging dose were evaluated in phantom and cadaver studies. Surgical localization performance was evaluated using three cadaver heads imaged as a function of θ tot . Six localization tasks were considered, ranging from high-contrast feature identification (e.g., tip of a K-wire pointer) to more challenging soft-tissue delineation (e.g., junction of the hard and soft palate). Five head and neck surgeons and one radiologist participated as observers. For each localization task, the 3D coordinates of landmarks pinpointed by each observer were analyzed as a function of θ tot . For all tomosynthesis angles, image quality was highest in the coronal plane, whereas sagittal and axial planes exhibited a substantial decrease in spatial resolution associated with out-of-plane blur and distortion. Tasks involving complex, lower-contrast features demonstrated steeper degradation with smaller tomosynthetic arc. Localization accuracy in the coronal plane was correspondingly high, maintained to tot ∼30 deg. , whereas sagittal and axial localization degraded rapidly below θ tot ∼60 deg. . Similarly, localization precision was better than ∼1 mm within the coronal plane, compared to ∼2-3 mm out-of-plane for tomosynthesis angles below θ tot ∼45 deg. . An overall 3D localization accuracy of ∼2.5 mm was achieved with θ tot ∼ 90 deg. for most

  9. The effects of scoliosis and subsequent surgery on the shape of the torso

    Directory of Open Access Journals (Sweden)

    Adrian Gardner

    2017-11-01

    Full Text Available Abstract Background Adolescent idiopathic scoliosis (AIS causes asymmetry of the torso, and this is often the primary concern of patients. Surgery aims to minimise the visual asymmetry. It is not clear how scoliosis makes the torso asymmetric or how scoliosis surgery changes that asymmetry when compared to the distribution of asymmetries seen in a non-scoliotic group of normal controls. Methods Surface topography images were captured for a group with AIS both pre-operatively and post-operatively. Identifiable points were compared between the images to identify the effects of AIS on the shape of the torso by looking at the relative heights and distances from the midline of the shoulders, axillae and waist in a two-dimensional coronal view. This was then compared to a previously reported group of normal non-scoliotic children to analyse whether surgery recreated normality. Results There were 172 pairs of images with 164 females and 8 males, mean age at pre-operative scan of 13.7 years. The normal group was 642 images (237 females and 405 males from 116 males and 79 females, mean age of 12.5 years. The curve patterns seen in the scoliotic group matched the patterns of a main thoracic curve (n = 146 and main thoracolumbar curve (n = 26. The asymmetries seen in both shoulders, axillae and waist were different between the two different types of curve. Across both groups, the shoulder asymmetry was less than that of the corresponding axillae. There was a statistically significant reduction in all asymmetries following surgery in the main thoracic group (p < 0.001. This was not seen in the main thoracolumbar group, thought to be due to the small sample size. In the main thoracic group, there were statistically significant differences in the asymmetries between the post-operative and normal groups in the shoulders and axillae (p < 0.001 but not the waist. Conclusions This paper demonstrates quantitatively the range of asymmetries seen

  10. Effective seat-to-head transmissibility in whole-body vibration: Effects of posture and arm position

    Science.gov (United States)

    Rahmatalla, Salam; DeShaw, Jonathan

    2011-12-01

    Seat-to-head transmissibility is a biomechanical measure that has been widely used for many decades to evaluate seat dynamics and human response to vibration. Traditionally, transmissibility has been used to correlate single-input or multiple-input with single-output motion; it has not been effectively used for multiple-input and multiple-output scenarios due to the complexity of dealing with the coupled motions caused by the cross-axis effect. This work presents a novel approach to use transmissibility effectively for single- and multiple-input and multiple-output whole-body vibrations. In this regard, the full transmissibility matrix is transformed into a single graph, such as those for single-input and single-output motions. Singular value decomposition and maximum distortion energy theory were used to achieve the latter goal. Seat-to-head transmissibility matrices for single-input/multiple-output in the fore-aft direction, single-input/multiple-output in the vertical direction, and multiple-input/multiple-output directions are investigated in this work. A total of ten subjects participated in this study. Discrete frequencies of 0.5-16 Hz were used for the fore-aft direction using supported and unsupported back postures. Random ride files from a dozer machine were used for the vertical and multiple-axis scenarios considering two arm postures: using the armrests or grasping the steering wheel. For single-input/multiple-output, the results showed that the proposed method was very effective in showing the frequencies where the transmissibility is mostly sensitive for the two sitting postures and two arm positions. For multiple-input/multiple-output, the results showed that the proposed effective transmissibility indicated higher values for the armrest-supported posture than for the steering-wheel-supported posture.

  11. Patient-specific model of a scoliotic torso for surgical planning

    Science.gov (United States)

    Harmouche, Rola; Cheriet, Farida; Labelle, Hubert; Dansereau, Jean

    2013-03-01

    A method for the construction of a patient-specific model of a scoliotic torso for surgical planning via inter-patient registration is presented. Magnetic Resonance Images (MRI) of a generic model are registered to surface topography (TP) and X-ray data of a test patient. A partial model is first obtained via thin-plate spline registration between TP and X-ray data of the test patient. The MRIs from the generic model are then fit into the test patient using articulated model registration between the vertebrae of the generic model's MRIs in prone position and the test patient's X-rays in standing position. A non-rigid deformation of the soft tissues is performed using a modified thin-plate spline constrained to maintain bone rigidity and to fit in the space between the vertebrae and the surface of the torso. Results show average Dice values of 0:975 +/- 0:012 between the MRIs following inter-patient registration and the surface topography of the test patient, which is comparable to the average value of 0:976 +/- 0:009 previously obtained following intra-patient registration. The results also show a significant improvement compared to rigid inter-patient registration. Future work includes validating the method on a larger cohort of patients and incorporating soft tissue stiffness constraints. The method developed can be used to obtain a geometric model of a patient including bone structures, soft tissues and the surface of the torso which can be incorporated in a surgical simulator in order to better predict the outcome of scoliosis surgery, even if MRI data cannot be acquired for the patient.

  12. Dual Arm Work Module Development and Appplications

    Energy Technology Data Exchange (ETDEWEB)

    Noakes, M.W.

    1999-04-25

    The dual arm work module (DAWM) was developed at Oak Ridge National Laboratory (ORNL) by the Robotics Technology Development Program (RTDP) as a development test bed to study issues related to dual arm manipulation, including platform cotilguration, controls, automation, operations, and tooling. The original platform was based on two Schilling Titan II manipulators mounted to a 5-degree-of- freedom (DOF) base fabricated by RedZone Robotics, Inc. The 5-DOF articulation provided a center torso rotation, linear actuation to change the separation between the arms, and arm base rotation joints to provide "elbows up," elbows down," or "elbows out" orientation. A series of tests were conducted on operations, tooling, and task space scene analysis (TSSA)-driven robotics for overhead transporter- mounted and crane hook-deployed scenarios. A concept was developed for DAWM deployment from a large remote work vehicle, but the project was redirected to support dismantlement of the Chicago Pile #5 (CP-5) reactor at Argonne National Laboratory in fiscal year (FY) 1997. Support of CP-5 required a change in focus of the dual arm technology from that of a development test bed to a system focussed for a specific end user. ORNL teamed with the Idaho National Environmental ,Engineering Laboratory, Sandia National Laboratory, and the Savannah River Technology Center to deliver a crane-deployed derivative of the DAWM, designated the dual arm work platform (DAWP). RTDP staff supported DAWP at CP-5 for one FY; Argonne staff continued operation through to dismantlement of the reactor internals. Lessons learned from this interaction were extensive. Beginning in FY 1999, dual arm development activities are again being pursued in the context of those lessons learned. This paper describes the progression of philosophy of the DAWM from initial test bed to lessons learned through interaction at CP-5 and to the present investigation of telerobotic assist of teleoperation and TSSA- driven robotics.

  13. Subclavian Vein Versus Arm Vein for Totally Implantable Central Venous Port for Patients with Head and Neck Cancer: A Retrospective Comparative Analysis

    International Nuclear Information System (INIS)

    Akahane, Akio; Sone, Miyuki; Ehara, Shigeru; Kato, Kenichi; Tanaka, Ryoichi; Nakasato, Tatsuhiko

    2011-01-01

    Purpose: This study was designed to compare central venous ports (CVP) from two different routes of venous access―the subclavian vein and arm vein―in terms of safety for patients with head and neck cancer (HNC). Methods: Patients with HNC who underwent image-guided implantations of CVPs were retrospectively evaluated. All CVPs were implanted under local anesthesia. Primary outcome measurements were rates and types of adverse events (AEs). Secondary outcomes included technical success and rate and reason of CVP removal. Results: A total of 162 patients (subclavian port group, 47; arm port group, 115) were included in this study. Technical success was achieved in all patients. The median follow-up period was 94 (range, 1–891) days. Two patients in the subclavian port group experienced periprocedural complications. Postprocedural AEs were observed in 8.5 and 22.6% of the subclavian port and arm port group patients, respectively (P = 0.044). Phlebitis and system occlusions were observed only in the arm port group. The rate of infection was not significantly different between the two groups. The CVP was removed in 34 and 39.1% of the subclavian port and arm port patients, respectively. Conclusions: Both subclavian and arm CVPs are feasible in patients with HNC. AEs were more frequent in the arm port group; thus, the arm port is not recommended as the first choice for patients with HNC. However, further experience is needed to improve the placement technique and the maintenance of CVPs and a prospective analysis is warranted.

  14. Comparative study of potential whiplash injuries for different occupant seated positions during rear end accidents.

    Science.gov (United States)

    Omerović, Senad; Tomasch, Ernst; Gutsche, Andreas J; Prebil, Ivan

    2016-01-01

    Whiplash injuries to the cervical spine represent a considerable economic burden on society with medical conditions, in some cases persisting for more than a year. Numerous studies of whiplash injuries have been made for occupant normal seated position, leaving the analysis of neck injuries for out-of-normal positions not well documented. For that purpose, a detailed human cervical spine finite element model was developed. The analysis was made for four most common occupant seated positions, such as: Normal Position with the torso against the seat back and the head looking straight ahead, Torso Lean forward position with the torso away from the seat back for approximately 10°, Head Flexed position with the head flexed forward approximately 20° from the normal position and Head-Flexed with Torso Lean forward position with the head flexed forward approximately 20° and torso 10° from the normal position. The comparative study included the analysis of capsular ligament deformation and the level of S-curvature of the cervical spine. The model developed predicted that Head Flexed seated position and Head-Flexed with Torso Lean forward seated position are most threatening for upper and lower cervical spine capsular ligament, respectively. As for the level of S-curvature, the model predicted that Head-Flexed with Torso Lean forward seated position would be most prone to neck injuries associated with it. This study demonstrated that the occupant seated position has a significant influence on potential whiplash injuries.

  15. Chemovirotherapy for head and neck squamous cell carcinoma with EGFR-targeted and CD/UPRT-armed oncolytic measles virus.

    Science.gov (United States)

    Zaoui, K; Bossow, S; Grossardt, C; Leber, M F; Springfeld, C; Plinkert, P K; Kalle, C von; Ungerechts, G

    2012-03-01

    First-line treatment of recurrent and/or refractory head and neck squamous cell carcinoma (HNSCC) is based on platinum, 5-fluorouracil (5-FU) and the monoclonal antiEGFR antibody cetuximab. However, in most cases this chemoimmunotherapy does not cure the disease, and more than 50% of HNSCC patients are dying because of local recurrence of the tumors. In the majority of cases, HNSCC overexpress the epidermal growth factor receptor (EGFR), and its presence is associated with a poor outcome. In this study, we engineered an EGFR-targeted oncolytic measles virus (MV), armed with the bifunctional enzyme cytosine deaminase/uracil phosphoribosyltransferase (CD/UPRT). CD/UPRT converts 5-fluorocytosine (5-FC) into the chemotherapeutic 5-FU, a mainstay of HNSCC chemotherapy. This virus efficiently replicates in and lyses primary HNSCC cells in vitro. Arming with CD/UPRT mediates efficient prodrug activation with high bystander killing of non-infected tumor cells. In mice bearing primary HNSCC xenografts, intratumoral administration of MV-antiEGFR resulted in statistically significant tumor growth delay and prolongation of survival. Importantly, combination with 5-FC is superior to virus-only treatment leading to significant tumor growth inhibition. Thus, chemovirotherapy with EGFR-targeted and CD/UPRT-armed MV is highly efficacious in preclinical settings with direct translational implications for a planned Phase I clinical trial of MV for locoregional treatment of HNSCC.

  16. Tissue-equivalent torso phantom for calibration of transuranic-nuclide counting facilities

    International Nuclear Information System (INIS)

    Griffith, R.V.; Anderson, A.L.; Dean, P.N.; Fisher, J.C.; Sundbeck, C.W.

    1986-01-01

    Several tissue-equivalent human-torso phantoms have been constructed for the calibration of counting systems used for in-vivo measurement of transuranic radionuclides. The phantoms contain a simulated human rib cage (in some cases, real bone) and removable model organs, and they include tissue-equivalent chest plates that can be placed over the torso to simulate people with a wide range of statures. The organs included are the lungs, liver, and tracheobronchial lymph nodes. Polyurethane with varying concentrations of added calcium was used to simulate the linear photon-attenuation properties of various human tissues, including lean muscle, adipose-muscle mixtures, cartilage, and bone. Foamed polyurethane was used to simulate lung tissue. Organs have been loaded with highly pure 238 Pu, 239 Pu, 241 Am, and other radionuclides of interest. The validity of the phantom as a calibration standard has been checked in separate intercomparison studies using human subjects whose lungs contained a plutonium simulant. The resulting phantom calibration factors generally compared to within +-20% of the average calibration factors obtained for the human subjects

  17. Emergency Sonography Aids Diagnostic Accuracy of Torso Injuries: A Study in a Resource Limited Setting

    Directory of Open Access Journals (Sweden)

    Charles Edward Tunuka

    2014-01-01

    Full Text Available Introduction. Clinical evaluation of patients with torso trauma is often a diagnostic challenge. Extended focused assessment with sonography for trauma (EFAST is an emergency ultrasound scan that adds to the evaluation of intrathoracic abdominal and pericardial cavities done in FAST (focused assessment with sonography for trauma. Objective. This study compares EFAST (the index test with the routine standard of care (SoC investigations (the standard reference test for torso trauma injuries. Methods. A cross-sectional descriptive study was conducted over a 3-month period. Eligible patients underwent EFAST scanning and the SoC assessment. The diagnostic accuracy of EFAST was calculated using sensitivity and specificity scores. Results. We recruited 197 patients; the M : F ratio was 5 : 1, with mean age of 27 years (SD 11. The sensitivity of EFAST was 100%, the specificity was 97%, the PPV was 87%, and the NPV was 100%. It took 5 minutes on average to complete an EFAST scan. 168 (85% patients were EFAST-scanned. Most patients (82 (48% were discharged on the same day of hospitalization, while 7 (4% were still at the hospital after two weeks. The mortality rate was 18 (9%. Conclusion. EFAST is a reliable method of diagnosing torso injuries in a resource limited context.

  18. The localization of focal heart activity via body surface potential measurements: tests in a heterogeneous torso phantom

    International Nuclear Information System (INIS)

    Wetterling, F; Liehr, M; Haueisen, J; Schimpf, P; Liu, H

    2009-01-01

    The non-invasive localization of focal heart activity via body surface potential measurements (BSPM) could greatly benefit the understanding and treatment of arrhythmic heart diseases. However, the in vivo validation of source localization algorithms is rather difficult with currently available measurement techniques. In this study, we used a physical torso phantom composed of different conductive compartments and seven dipoles, which were placed in the anatomical position of the human heart in order to assess the performance of the Recursively Applied and Projected Multiple Signal Classification (RAP-MUSIC) algorithm. Electric potentials were measured on the torso surface for single dipoles with and without further uncorrelated or correlated dipole activity. The localization error averaged 11 ± 5 mm over 22 dipoles, which shows the ability of RAP-MUSIC to distinguish an uncorrelated dipole from surrounding sources activity. For the first time, real computational modelling errors could be included within the validation procedure due to the physically modelled heterogeneities. In conclusion, the introduced heterogeneous torso phantom can be used to validate state-of-the-art algorithms under nearly realistic measurement conditions.

  19. The localization of focal heart activity via body surface potential measurements: tests in a heterogeneous torso phantom

    Science.gov (United States)

    Wetterling, F.; Liehr, M.; Schimpf, P.; Liu, H.; Haueisen, J.

    2009-09-01

    The non-invasive localization of focal heart activity via body surface potential measurements (BSPM) could greatly benefit the understanding and treatment of arrhythmic heart diseases. However, the in vivo validation of source localization algorithms is rather difficult with currently available measurement techniques. In this study, we used a physical torso phantom composed of different conductive compartments and seven dipoles, which were placed in the anatomical position of the human heart in order to assess the performance of the Recursively Applied and Projected Multiple Signal Classification (RAP-MUSIC) algorithm. Electric potentials were measured on the torso surface for single dipoles with and without further uncorrelated or correlated dipole activity. The localization error averaged 11 ± 5 mm over 22 dipoles, which shows the ability of RAP-MUSIC to distinguish an uncorrelated dipole from surrounding sources activity. For the first time, real computational modelling errors could be included within the validation procedure due to the physically modelled heterogeneities. In conclusion, the introduced heterogeneous torso phantom can be used to validate state-of-the-art algorithms under nearly realistic measurement conditions.

  20. 49 CFR 572.195 - Thorax with arm.

    Science.gov (United States)

    2010-10-01

    ... dummy is in vertical orientation. (4) Push the dummy at the knees and at mid-sternum of the upper torso with just sufficient horizontally oriented force towards the seat back until the back of the upper torso is in contact with the seat back. (5) While maintaining the dummy's position as specified in...

  1. In vitro methods for evaluating skin hydration under diapers and incontinence products.

    Science.gov (United States)

    Tate, M L; Wright, A S

    2017-11-01

    Excessive skin hydration from wearing wet undergarments, such as infant diapers and adult incontinence products, has been historically problematic. Skin damage occurs from wetness (urine) and limited product breathability. Evaporative water loss has been measured on adult arms (armband method) or infant torsos (on-baby method), after wearing a saline-insulted diaper product. The current study developed a reliable in vitro method of evaluating diaper and incontinence products for improvements in skin dryness. A simulated skin substrate was applied to a heated mechanical arm or baby torso. A disposable diaper or incontinence product was wrapped around the arm or baby torso, and loaded with saline. Hydration of the simulated skin was measured by evaporimetry and compared with clinical data from adult armband evaluations. The heated mechanical arm and baby torso accurately distinguished products for skin dryness. Eight diaper products were evaluated and compared to human test results. The torso in vitro and mechanical arm evaluations demonstrated strong correlations to human epidermal water loss evaluations, with repeatable results. Additionally, the bench test has been used for adult incontinence products, and it proved to differentiate those products as well as infant products. A rapid and reliable means of evaluation has been developed, and it is predictive of human subject testing. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  2. Quantitative prediction of respiratory tidal volume based on the external torso volume change: a potential volumetric surrogate

    International Nuclear Information System (INIS)

    Li Guang; Arora, Naveen C; Xie Huchen; Ning, Holly; Citrin, Deborah; Kaushal, Aradhana; Zach, Leor; Camphausen, Kevin; Miller, Robert W; Lu Wei; Low, Daniel

    2009-01-01

    An external respiratory surrogate that not only highly correlates with but also quantitatively predicts internal tidal volume should be useful in guiding four-dimensional computed tomography (4DCT), as well as 4D radiation therapy (4DRT). A volumetric surrogate should have advantages over external fiducial point(s) for monitoring respiration-induced motion of the torso, which deforms in synchronization with a patient-specific breathing pattern. This study establishes a linear relationship between the external torso volume change (TVC) and lung air volume change (AVC) by validating a proposed volume conservation hypothesis (TVC = AVC) throughout the respiratory cycle using 4DCT and spirometry. Fourteen patients' torso 4DCT images and corresponding spirometric tidal volumes were acquired to examine this hypothesis. The 4DCT images were acquired using dual surrogates in cine mode and amplitude-based binning in 12 respiratory stages, minimizing residual motion artifacts. Torso and lung volumes were calculated using threshold-based segmentation algorithms and volume changes were calculated relative to the full-exhalation stage. The TVC and AVC, as functions of respiratory stages, were compared, showing a high correlation (r = 0.992 ± 0.005, p 2 = 0.980) without phase shift. The AVC was also compared to the spirometric tidal volumes, showing a similar linearity (slope = 1.030 ± 0.092, R 2 = 0.947). In contrast, the thoracic and abdominal heights measured from 4DCT showed relatively low correlation (0.28 ± 0.44 and 0.82 ± 0.30, respectively) and location-dependent phase shifts. This novel approach establishes the foundation for developing an external volumetric respiratory surrogate.

  3. Accuracy of conventional imaging of penetrating torso injuries in the trauma resuscitation room

    NARCIS (Netherlands)

    D.S.E. Varin (Dorien); A.N. Ringburg (Akkie); E.M.M. van Lieshout (Esther); P. Patka (Peter); I.B. Schipper (Inger)

    2009-01-01

    textabstractChest X-ray (CXR), abdominal ultrasound, cardiac ultrasound, and abdominal X-ray are the most frequently used imaging modalities to radiologically evaluate patients with penetrating torso trauma. The aim of this study was to evaluate the accuracy of these imaging modalities. From January

  4. The impact of arm position on the measurement of orthostatic blood pressure.

    Science.gov (United States)

    Guss, David A; Abdelnur, Diego; Hemingway, Thomas J

    2008-05-01

    Blood pressure is a standard vital sign in patients evaluated in an Emergency Department. The American Heart Association has recommended a preferred position of the arm and cuff when measuring blood pressure. There is no formal recommendation for arm position when measuring orthostatic blood pressure. The objective of this study was to assess the impact of different arm positions on the measurement of postural changes in blood pressure. This was a prospective, unblinded, convenience study involving Emergency Department patients with complaints unrelated to cardiovascular instability. Repeated blood pressure measurements were obtained using an automatic non-invasive device with each subject in a supine and standing position and with the arm parallel and perpendicular to the torso. Orthostatic hypotension was defined as a difference of >or= 20 mm Hg systolic or >or= 10 mm Hg diastolic when subtracting standing from supine measurements. There were four comparisons made: group W, arm perpendicular supine and standing; group X, arm parallel supine and standing; group Y, arm parallel supine and perpendicular standing; and group Z, arm perpendicular supine and parallel standing. There were 100 patients enrolled, 55 men, mean age 44 years. Four blood pressure measurements were obtained on each patient. The percentage of patients meeting orthostatic hypotension criteria in each group was: W systolic 6% (95% CI 1%, 11%), diastolic 4% (95% CI 0%, 8%), X systolic 8% (95% CI 3%, 13%), diastolic 9% (95% CI 3%, 13%), Y systolic 19% (95% CI 11%, 27%), diastolic 30% (95% CI 21%, 39%), Z systolic 2% (95% CI 0%, 5%), diastolic 2% (95% CI 0%, 5%). Comparison of Group Y vs. X, Z, and W was statistically significant (p postural changes in blood pressure. The combination of the arm parallel when supine and perpendicular when standing may significantly overestimate the orthostatic change. Arm position should be held constant in supine and standing positions when assessing for orthostatic

  5. Improved torso modelling and its influence on the localization of arhythmogenic center(s) in hearth

    Energy Technology Data Exchange (ETDEWEB)

    Jazbinsek, V; Trontelj, Z [Ljubljana Univ. (Yugoslavia). Dept. of Physics; Burghoff, M; Zimmermann, R [Physikalisch-Technische Bundesanstalt - Inst. Berlin (Germany); Oeff, M [Freie Univ. Berlin (Germany). Fachbereich Universitaetsklinikum Steglitz

    1994-11-01

    It is desirable to get noninvasively the information on the spatial position of anomalies in the cardiac conduction system. Body surface potential map and/or magnetic field distribution in the vicinity of a human chest are obtained from cardiographic measurements. With this information we start the necessary forward and inverse calculations. In this work several types of torso models (realistic torso with the NMR support, elliptic, cylinder) have been used to analyse 7 patients with Wolf-Parkinson-White syndrome. The spatial coordinates of the tip of ablation catheter, obtained by the X-ray system, have been used as a reference in the evaluation procedure of current source coordinates (the onset of the accessory pathway), calculated from the noninvasive magnetic measurements. (author). 10 refs., 2 figs., 2 tabs.

  6. Human torso phantom for imaging of heart with realistic modes of cardiac and respiratory motion

    Science.gov (United States)

    Boutchko, Rostyslav; Balakrishnan, Karthikayan; Gullberg, Grant T; O& #x27; Neil, James P

    2013-09-17

    A human torso phantom and its construction, wherein the phantom mimics respiratory and cardiac cycles in a human allowing acquisition of medical imaging data under conditions simulating patient cardiac and respiratory motion.

  7. Quantitative prediction of respiratory tidal volume based on the external torso volume change: a potential volumetric surrogate

    Energy Technology Data Exchange (ETDEWEB)

    Li Guang; Arora, Naveen C; Xie Huchen; Ning, Holly; Citrin, Deborah; Kaushal, Aradhana; Zach, Leor; Camphausen, Kevin; Miller, Robert W [Radiation Oncology Branch, National Cancer Institute, National Institutes of Health, Bethesda, MD 20892 (United States); Lu Wei; Low, Daniel [Department of Radiation Oncology, Washington University School of Medicine, St Louis, MO 63110 (United States)], E-mail: ligeorge@mail.nih.gov

    2009-04-07

    An external respiratory surrogate that not only highly correlates with but also quantitatively predicts internal tidal volume should be useful in guiding four-dimensional computed tomography (4DCT), as well as 4D radiation therapy (4DRT). A volumetric surrogate should have advantages over external fiducial point(s) for monitoring respiration-induced motion of the torso, which deforms in synchronization with a patient-specific breathing pattern. This study establishes a linear relationship between the external torso volume change (TVC) and lung air volume change (AVC) by validating a proposed volume conservation hypothesis (TVC = AVC) throughout the respiratory cycle using 4DCT and spirometry. Fourteen patients' torso 4DCT images and corresponding spirometric tidal volumes were acquired to examine this hypothesis. The 4DCT images were acquired using dual surrogates in cine mode and amplitude-based binning in 12 respiratory stages, minimizing residual motion artifacts. Torso and lung volumes were calculated using threshold-based segmentation algorithms and volume changes were calculated relative to the full-exhalation stage. The TVC and AVC, as functions of respiratory stages, were compared, showing a high correlation (r = 0.992 {+-} 0.005, p < 0.0001) as well as a linear relationship (slope = 1.027 {+-} 0.061, R{sup 2} = 0.980) without phase shift. The AVC was also compared to the spirometric tidal volumes, showing a similar linearity (slope = 1.030 {+-} 0.092, R{sup 2} = 0.947). In contrast, the thoracic and abdominal heights measured from 4DCT showed relatively low correlation (0.28 {+-} 0.44 and 0.82 {+-} 0.30, respectively) and location-dependent phase shifts. This novel approach establishes the foundation for developing an external volumetric respiratory surrogate.

  8. Modeling humanoid swarm robots with petri nets

    OpenAIRE

    Maharjan, Bikee

    2015-01-01

    Master's thesis in Computer science Robots have become a hot topic in today‟s electronic world. There are many definitions for it. One of the definition in Oxford dictionary states “a robot is a machine capable for carrying out a complex series of action automatically especially one programmable by a computer”. This paper deals with a special kind of robot, which is also known as humanoid robot. These robots are replication of human beings with head, torso, arms and legs. A model of hum...

  9. Noncompressible Torso Hemorrhage: A Review with Contemporary Definitions and Management Strategies

    Science.gov (United States)

    2012-01-01

    Criteria 1. Thoracic cavity (including lung ) 2. Solid organ injury grade 4 (liver, kidney, spleen) Hemorrhagic shocka; or need for immediate operation 3...resuscitation and warming in the intensive care unit. DCS is an extreme surgical strategy that carries a risk of infection; intra-abdominal abscess ...depending on location. Injury to the periphery Noncompressible Torso Hemorrhage 849 of the lung can be stapled off in a nonanatomic fashion using a linear

  10. Current management of penetrating torso trauma: nontherapeutic is not good enough anymore.

    Science.gov (United States)

    Ball, Chad G

    2014-04-01

    A highly organized approach to the evaluation and treatment of penetrating torso injuries based on regional anatomy provides rapid diagnostic and therapeutic consistency. It also minimizes delays in diagnosis, missed injuries and nontherapeutic laparotomies. This review discusses an optimal sequence of structured rapid assessments that allow the clinician to rapidly proceed to gold standard therapies with a minimal risk of associated morbidity.

  11. SAR and thermal response effects of a two-arm Archimedean spiral coil in a magnetic induction sensor on a human head.

    Science.gov (United States)

    Zhang, Ziyi; Liu, Peiguo; Zhou, Dongming; Zhang, Liang; Ding, Liang

    2015-01-01

    This study investigates the radiation safety of a newly designed magnetic induction sensor. This novel magnetic induction sensor uses a two-arm Archimedean spiral coil (TAASC) as the exciter. A human head model with a real anatomical structure was used to calculate the specific absorption rate (SAR) and temperature change. Computer Simulation Technology (CST) was used to determine the values of the peak 10-g SAR under different operating parameters (current, frequency, horizontal distance between the excitation coil and the receiver coil, vertical distance between the top of the head model and the XOY plane, position of excitation coil, and volume of hemorrhage). Then, the highest response for the SAR and temperature rise was determined. The results showed that this new magnetic induction sensor is safe in the initial state; for safety reasons, the TAASC current should not exceed 4 A. The scalp tissue absorbed most of the electromagnetic energy. The TAASC's SAR/thermal performance was close to that of the circular coil.

  12. Supernumerary head of biceps brachii and branching pattern of the musculocutaneous nerve

    Directory of Open Access Journals (Sweden)

    Mohan Basavaraj Angadi

    2016-01-01

    Full Text Available During routine dissection by medical undergraduates, third head of the biceps brachii muscle was found on the left side of a 75-year-old male cadaver in a total of 48 arms dissected in Department of Anatomy Armed Forces Medical College, Pune. Biceps brachii is a muscle of arm having two heads hence the name. The most frequent variation of the muscle is in the number of heads with a prevalence range of 9.1-22.9%. The origin of the supernumerary head in this case was from the humerus, between the insertion of the coracobrachialis and the upper part of the origin of the brachialis, and also from the medial intermuscular septum. The supernumerary head joined the common belly. It was supplied by the musculocutaneous nerve which after emerging from brachialis pierced it near the middle and terminated by finally supplying the biceps belly. In our study, 2.08% (1 of 48 of male cadavers were found to have the third head of biceps. The incidence of this variation can be as much as 10% as, shown in previous studies on Indian population, as reported in standard textbooks of anatomy.

  13. Development of age-specific Japanese physical phantoms for dose evaluation in infant CT examinations

    International Nuclear Information System (INIS)

    Yamauchi-Kawaura, C.; Fujii, K.; Imai, K.; Ikeda, M.; Akahane, K.; Obara, S.; Yamauchi, M.; Narai, K.; Katsu, T.

    2016-01-01

    Secondary to the previous development of age-specific Japanese head phantoms, the authors designed Japanese torso phantoms for dose assessment in infant computed tomography (CT) examinations and completed a Japanese 3-y-old head-torso phantom. For design of age-specific torso phantoms (0, 0.5, 1 and 3 y old), anatomical structures were measured from CT images of Japanese infant patients. From the CT morphometry, it was found that rib cages of Japanese infants were smaller than those in Europeans and Americans. Radiophotoluminescence glass dosemeters were used for dose measurement of a 3-y-old head-torso phantom. To examine the validity of the developed phantom, organ and effective doses by the in-phantom dosimetry system were compared with simulation values in a web-based CT dose calculation system (WAZA-ARI). The differences in doses between the two systems were <20 % at the doses of organs within scan regions and effective doses in head, chest and abdomino-pelvic CT examinations. (authors)

  14. A research on the postural stability of a person wearing the lower limb exoskeletal robot by the HAT model.

    Science.gov (United States)

    Chang, Minsu; Kim, Yeongmin; Lee, Yoseph; Jeon, Doyoung

    2017-07-01

    This paper proposes a method of detecting the postural stability of a person wearing the lower limb exoskeletal robot with the HAT(Head-Arm-Trunk) model. Previous studies have shown that the human posture is stable when the CoM(Center of Mass) of the human body is placed on the BoS(Base of Support). In the case of the lower limb exoskeletal robot, the motion data, which are used for the CoM estimation, are acquired by sensors in the robot. The upper body, however, does not have sensors in each segment so that it may cause the error of the CoM estimation. In this paper, the HAT(Head-Arm-Trunk) model which combines head, arms, and torso into a single segment is considered because the motion of head and arms are unknown due to the lack of sensors. To verify the feasibility of HAT model, the reflecting markers are attached to each segment of the whole human body and the exact motion data are acquired by the VICON to compare the COM of the full body model and HAT model. The difference between the CoM with full body and that with HAT model is within 20mm for the various motions of head and arms. Based on the HAT model, the XCoM(Extrapolated Center of Mass) which includes the velocity of the CoM is used for prediction of the postural stability. The experiment of making unstable posture shows that the XCoM of the whole body based on the HAT model is feasible to detect the instance of postural instability earlier than the CoM by 20-250 msec. This result may be used for the lower limb exoskeletal robot to prepare for any action to prevent the falling down.

  15. Calibration of lung counter using a CT model of Torso phantom and Monte Carlo method

    International Nuclear Information System (INIS)

    Zhang Binquan; Ma Jizeng; Yang Duanjie; Liu Liye; Cheng Jianping

    2006-01-01

    Tomography image of a Torso phantom was obtained from CT-Scan. The Torso phantom represents the trunk of an adult man that is 170 cm high and weight of 65 kg. After these images were segmented, cropped, and resized, a 3-dimension voxel phantom was created. The voxel phantom includes more than 2 million voxels, which size was 2.73 mm x 2.73 mm x 3 mm. This model could be used for the calibration of lung counter with Monte Carlo method. On the assumption that radioactive material was homogeneously distributed throughout the lung, counting efficiencies of a HPGe detector in different positions were calculated as Adipose Mass fraction (AMF) was different in the soft tissue in chest. The results showed that counting efficiencies of the lung counter changed up to 67% for 17.5 keV γ ray and 20% for 25 keV γ ray when AMF changed from 0 to 40%. (authors)

  16. Whole-body voxel phantoms of paediatric patients—UF Series B

    Science.gov (United States)

    Lee, Choonik; Lee, Choonsik; Williams, Jonathan L.; Bolch, Wesley E.

    2006-09-01

    Following the previous development of the head and torso voxel phantoms of paediatric patients for use in medical radiation protection (UF Series A), a set of whole-body voxel phantoms of paediatric patients (9-month male, 4-year female, 8-year female, 11-year male and 14-year male) has been developed through the attachment of arms and legs from segmented CT images of a healthy Korean adult (UF Series B). Even though partial-body phantoms (head-torso) may be used in a variety of medical dose reconstruction studies where the extremities are out-of-field or receive only very low levels of scatter radiation, whole-body phantoms play important roles in general radiation protection and in nuclear medicine dosimetry. Inclusion of the arms and legs is critical for dosimetry studies of paediatric patients due to the presence of active bone marrow within the extremities of children. While the UF Series A phantoms preserved the body dimensions and organ masses as seen in the original patients who were scanned, comprehensive adjustments were made for the Series B phantoms to better match International Commission on Radiological Protection (ICRP) age-interpolated reference body masses, body heights, sitting heights and internal organ masses. The CT images of arms and legs of a Korean adult were digitally rescaled and attached to each phantom of the UF series. After completion, the resolutions of the phantoms for the 9-month, 4-year, 8-year, 11-year and 14-year were set at 0.86 mm × 0.86 mm × 3.0 mm, 0.90 mm × 0.90 mm × 5.0 mm, 1.16 mm × 1.16 mm × 6.0 mm, 0.94 mm × 0.94 mm × 6.00 mm and 1.18 mm × 1.18 mm × 6.72 mm, respectively.

  17. Involvement of upper torso stress amplification, tissue compression and distortion in the pathogenesis of keloids.

    Science.gov (United States)

    Bux, Shamin; Madaree, Anil

    2012-03-01

    Keloids are benign tumours composed of fibrous tissue produced during excessive tissue repair triggered by minor injury, trauma or surgical incision. Although it is recognized that keloids have a propensity to form in the upper torso of the body, the predisposing factors responsible for this have not been investigated. It is crucial that the aetiopathoical factors implicated in keloid formation be established to provide guidelines for well-informed more successful treatment. We compared keloid-prone and keloid-protected skin, identified pertinent morphological differences and explored how inherent structural characteristics and intrinsic factors may promote keloid formation. It was determined that keloid prone areas were covered with high tension skin that had low stretch and a low elastic modulus when compared with skin in keloid protected areas where the skin was lax with a high elastic modulus and low pre-stress level. Factors contributing to elevated internal stress in keloid susceptible skin were the protrusion of hard connective tissue such as bony prominences or cartilage into the dermis of skin as well as inherent skin characteristics such as the bundled arrangement of collagen in the reticular dermis, the existent high tension, the low elastic modulus, low stretch ability, contractile forces exerted by wound healing fibroblastic cells and external forces. Stress promotes keloid formation by causing dermal distortion and compression which subsequently stimulate proliferation and enhanced protein synthesis in wound healing fibroblastic cells. The strain caused by stress also compresses and occludes microvessels causing ischaemic effects and reperfusion injury which stimulate growth when blood rich in growth factors returns to the tissue. The growth promoting effects of increased internal stress, primarily, and growth factors released by reperfusing blood, manifest in keloid formation. Other inherent skin characteristics promoting keloid growth during the

  18. Non-invasive head fixation for external irradiation of tumors of the head and neck

    International Nuclear Information System (INIS)

    Bale, R.J.; Sweeney, R.; Nevinny, M.; Auer, T.; Bluhm, A.; Lukas, P.; Vogele, M.; Thumfart, W.F.

    1998-01-01

    Purpose: To fully utilize the technical capabilities of radiation diagnostics and planning, a precise and reproducible method of head fixation is a prerequisite. Method: We have adapted the Vogele-Bale-Hohner (VBH) head holder (Wellhoefer Dosimetrie, Schwarzenbruck, Germany), originally designed for frameless stereotactic operations, to the requirements of external beam radiotherapy. A precise and reproducible head fixation is attained by an individualized vacuum upper-dental cast which is connected over 2 hydraulic arms to an adjustable head- and rigid base-plate. Radiation field and patient alignment lasers are marked on a relocatable clear PVC localization box. Results: The possibility of craniocaudal adjustment of the head plate on the base plate allows the system to adapt to the actucal position of the patient on the raditherapy couch granting tensionless repositioning. The VBH head holder has proven itself to be a precise yet practicable method of head fixation. Duration of mouthpiece production and daily repositioning is comparable to that of the thermoplastic mask. Conclusion: The new head holder is in routine use at our hospital and quite suitable for external beam radiation of patients with tumors of the head and neck. (orig.) [de

  19. Depth Dose Distribution Study within a Phantom Torso after Irradiation with a Simulated Solar Particle Event at NSRL

    Science.gov (United States)

    Berger, Thomas; Matthiae, Daniel; Koerner, Christine; George, Kerry; Rhone, Jordan; Cucinotta, Francis; Reitz, Guenther

    2010-01-01

    The adequate knowledge of the radiation environment and the doses incurred during a space mission is essential for estimating an astronaut's health risk. The space radiation environment is complex and variable, and exposures inside the spacecraft and the astronaut's body are compounded by the interactions of the primary particles with the atoms of the structural materials and with the body itself Astronauts' radiation exposures are measured by means of personal dosimetry, but there remains substantial uncertainty associated with the computational extrapolation of skin dose to organ dose, which can lead to over- or underestimation of the health risk. Comparisons of models to data showed that the astronaut's Effective dose (E) can be predicted to within about a +10% accuracy using space radiation transport models for galactic cosmic rays (GCR) and trapped radiation behind shielding. However for solar particle event (SPE) with steep energy spectra and for extra-vehicular activities on the surface of the moon where only tissue shielding is present, transport models predict that there are large differences in model assumptions in projecting organ doses. Therefore experimental verification of SPE induced organ doses may be crucial for the design of lunar missions. In the research experiment "Depth dose distribution study within a phantom torso" at the NASA Space Radiation Laboratory (NSRL) at BNL, Brookhaven, USA the large 1972 SPE spectrum was simulated using seven different proton energies from 50 up to 450 MeV. A phantom torso constructed of natural bones and realistic distributions of human tissue equivalent materials, which is comparable to the torso of the MATROSHKA phantom currently on the ISS, was equipped with a comprehensive set of thermoluminescence detectors and human cells. The detectors are applied to assess the depth dose distribution and radiation transport codes (e.g. GEANT4) are used to assess the radiation field and interactions of the radiation field

  20. The Epidemiology of Noncompressible Torso Hemorrhage in the Wars in Iraq and Afghanistan

    Science.gov (United States)

    2013-03-01

    torso vascular or pulmonary hemorrhage. Recently, Zonies and Eastridge20 reported 10 years of wartime splenic trauma man- agement with a series of 393...benchmark. J Vasc Surg. 2012;56:728Y736. 20. Zonies D, Eastridge B. Combat management of splenic injury: trends during a decade of conflict. J Trauma ...is the leading cause of potentially survivable trauma in the battlefield and has re- cently been defined using anatomic and physiologic criteria

  1. The future of U.S.-Russia nuclear arms control

    Science.gov (United States)

    Pifer, Steven

    2017-11-01

    Nuclear arms control has long made contributions to U.S.-Soviet and U.S.-Russian security, but the current regime is at risk. The 1987 Intermediate-range Nuclear Forces Treaty may be headed for collapse. Both the United States and Russia are modernizing their strategic forces, and the fate of the 2010 New Strategic Arms Reduction Treaty is unclear. In the unlikely case that the sides are prepared to go beyond New START, there are ways to address further reductions and related issues. A collapse of the arms control regime, on the other hand, would mean the end of constraints on U.S. and Russian nuclear forces, a significant loss of transparency, and potential costs to U.S. security.

  2. Development of re-locatable head frame system using hydraulic arms for fractionated stereotactic radiotherapy and CT evaluation of repositioning accuracy

    International Nuclear Information System (INIS)

    Kitamura, Masayuki; Kunieda, Etsuo; Kawaguchi, Osamu; Ando, Yutaka; Shigematsu, Naoyuki; Shiba, Toshiyuki; Kubo, Atsushi

    2002-01-01

    The purpose of this study was to develop a novel re-locatable head frame system consisting of a dental cast and hydraulic arms as an immobilization device for fractionated stereotactic radiotherapy and to evaluate the repositioning accuracy by measurement of landmark coordinates in repeated computed tomography (CT) examinations. The acrylic dental casts were customized for each patient. First the dental cast was attached to the upper jaw of the patient, then the dental cast was connected to a Leksell stereotactic frame, which was finally secured by two hydraulic arms. Since this system is compatible with the Leksell frame, stereotactic indicators could be used to obtain coordinates of anatomical landmarks of the head. Seven patients treated by fractionated stereotactic radiotherapy underwent repeated quality-assurance CTs during their treatment courses. We evaluated the coordinates of the short process of incus and the top of crista galli as reference points for evaluation of variation in a total of 26 repeat CT data sets, and then x, y, and z fluctuations relative to their positions in the treatment-planning CTs. The distances among the reference points of both processes of incus and the top of crista galli were calculated to evaluate the feasibility of the method. The distances were less than 0.5 mm on averages and less than 1 mm in the standard deviations. The respective fluctuations in the x, y and z directions were less than 1 mm in mean values and less than 2 mm in standard deviations. The fluctuations in distance were less than 2 mm on average and in standard deviations. The fluctuation of the center of three reference points was 0.7 mm on average and the rotation of the cranium was 1.0 degree in average. We concluded that our evaluation method is feasible and the reproducibility of the fixation system is acceptable for its routine use in stereotactic radiotherapy. (author)

  3. Radiology trainer. Torso, internal organs and vessels. 2. ed.; Radiologie-Trainer. Koerperstamm, innere Organe und Gefaesse

    Energy Technology Data Exchange (ETDEWEB)

    Staebler, Axel [Orthopaedische Klinik Harlaching, Muenchen (Germany). Radiologische Praxis; Erlt-Wagner, Birgit (eds.) [Klinikum der Universitaet Muenchen (Germany). Inst. fuer Klinische Radiologie

    2013-11-01

    The radiology training textbook is based on case studies of the clinical experience, including radiological imaging and differential diagnostic discussion. The scope of this volume covers the torso, internal organs and vessels. The following issues are discussed: lungs, pleura, mediastinum; heart and vascular system; upper abdomen organs; gastrointestinal tract; urogenital system.

  4. Role of age and injury mechanism on cervical spine injury tolerance from head contact loading.

    Science.gov (United States)

    Yoganandan, Narayan; Chirvi, Sajal; Voo, Liming; Pintar, Frank A; Banerjee, Anjishnu

    2018-02-17

    The objective of this study was to determine the influence of age and injury mechanism on cervical spine tolerance to injury from head contact loading using survival analysis. This study analyzed data from previously conducted experiments using post mortem human subjects (PMHS). Group A tests used the upright intact head-cervical column experimental model. The inferior end of the specimen was fixed, the head was balanced by a mechanical system, and natural lordosis was removed. Specimens were placed on a testing device via a load cell. The piston applied loading at the vertex region. Spinal injuries were identified using medical images. Group B tests used the inverted head-cervical column experimental model. In one study, head-T1 specimens were fixed distally, and C7-T1 joints were oriented anteriorly, preserving lordosis. Torso mass of 16 kg was added to the specimen. In another inverted head-cervical column study, occiput-T2 columns were obtained, an artificial head was attached, T1-T2 was fixed, C4-C5 disc was maintained horizontal in the lordosis posture, and C7-T1 was unconstrained. The specimens were attached to the drop test carriage carrying a torso mass of 15 kg. A load cell at the inferior end measured neck loads in both studies. Axial neck force and age were used as the primary response variable and covariate to derive injury probability curves using survival analysis. Group A tests showed that age is a significant (P < .05) and negative covariate; that is, increasing age resulted in decreasing force for the same risk. Injuries were mainly vertebral body fractures and concentrated at one level, mid-to-lower cervical spine, and were attributed to compression-related mechanisms. However, age was not a significant covariate for the combined data from group B tests. Both group B tests produced many soft tissue injuries, at all levels, from C1 to T1. The injury mechanism was attributed to mainly extension. Multiple and noncontiguous injuries occurred

  5. Functional morphology of the primate head and neck.

    Science.gov (United States)

    Nalley, Thierra K; Grider-Potter, Neysa

    2015-04-01

    The vertebral column plays a key role in maintaining posture, locomotion, and transmitting loads between body components. Cervical vertebrae act as a bridge between the torso and head and play a crucial role in the maintenance of head position and the visual field. Despite its importance in positional behaviors, the functional morphology of the cervical region remains poorly understood, particularly in comparison to the thoracic and lumbar sections of the spinal column. This study tests whether morphological variation in the primate cervical vertebrae correlates with differences in postural behavior. Phylogenetic generalized least-squares analyses were performed on a taxonomically broad sample of 26 extant primate taxa to test the link between vertebral morphology and posture. Kinematic data on primate head and neck postures were used instead of behavioral categories in an effort to provide a more direct analysis of our functional hypothesis. Results provide evidence for a function-form link between cervical vertebral shape and postural behaviors. Specifically, taxa with more pronograde heads and necks and less kyphotic orbits exhibit cervical vertebrae with longer spinous processes, indicating increased mechanical advantage for deep nuchal musculature, and craniocaudally longer vertebral bodies and more coronally oriented zygapophyseal articular facets, suggesting an emphasis on curve formation and maintenance within the cervical lordosis, coupled with a greater resistance to translation and ventral displacement. These results not only document support for functional relationships in cervical vertebrae features across a wide range of primate taxa, but highlight the utility of quantitative behavioral data in functional investigations. © 2015 Wiley Periodicals, Inc.

  6. Pilomatrixoma of the Arm: A Rare Case with Cytologic Diagnosis

    Directory of Open Access Journals (Sweden)

    Ruchika Gupta

    2012-01-01

    Full Text Available Pilomatrixoma, a benign skin appendageal tumor, is seen commonly in head and neck. Occurrence of pilomatrixoma in the upper extremities is not common and has been reported infrequently in the available literature. Only a few cases with preoperative aspiration cytology have been reported in the literature. A five-year-old girl underwent fine needle aspiration (FNA of a firm subcutaneous nodule on the lateral aspect of left arm. FNA smears showed scattered and few fragments of round to oval cells along with multinucleated giant cells. Few shadow cells were seen. A cytologic impression of pilomatrixoma was rendered, which was confirmed on histopathology. Pilomatrixoma, a common skin appendageal tumor in head and neck region, should be considered in the cytologic differential diagnoses of subcutaneous masses even in unusual locations like arm. The varied cytomorphology should be remembered to avoid misdiagnosis.

  7. The Influences of Arm Resist Motion on a CAR Crash Test Using Hybrid III Dummy with Human-Like Arm

    Science.gov (United States)

    Kim, Yongchul; Youm, Youngil; Bae, Hanil; Choi, Hyeonki

    Safety of the occupant during the crash is very essential design element. Many researches have been investigated in reducing the fatal injury of occupant. They are focusing on the development of a dummy in order to obtain the real human-like motion. However, they have not considered the arm resist motion during the car accident. In this study, we would like to suggest the importance of the reactive force of the arm in a car crash. The influences of reactive force acting on the human upper extremity were investigated using the impedance experimental method with lumped mass model of hand system and a Hybrid III dummy with human-like arm. Impedance parameters (e.g. inertia, spring constant and damping coefficient) of the elbow joint in maximum activation level were measured by free oscillation test using single axis robot. The results showed that without seat belt, the reactive force of human arm reduced the head, chest, and femur injury, and the flexion moment of the neck is higher than that of the conventional dummy.

  8. Supportive use of megestrol acetate (Megace) with head/neck and lung cancer patients receiving radiation therapy

    International Nuclear Information System (INIS)

    McQuellon, Richard P.; Moose, Dawn B.; Russell, Gregory B.; Case, L. Douglas; Greven, Katherine; Stevens, Michael; Shaw, Edward G.

    2002-01-01

    Purpose: The purpose of this study was to measure the effect of megestrol acetate (MA) on weight loss and quality of life (QOL) in patients with cancer of the lung or head and neck undergoing curative radiation therapy. Methods and Materials: This was a Phase III, placebo-controlled, double-blind randomized study. Patients received either 800 mg/day of MA (20 milliliters po qAM) or placebo over a 12-week period. Patients received radiation of the head and neck or thorax using a dose of at least 50 Gy, either alone or with chemotherapy. Weight was assessed weekly, whereas QOL was assessed at baseline and at 4, 8, and 12 weeks. Results: Patient characteristics on the MA arm (16 lung, 12 head/neck; mean age: 60 years) were similar to those on the placebo arm (17 lung, 11 head/neck; mean age: 65.8 years). Patients in the MA group had a mean weight loss over 12 weeks of 2.7 pounds, whereas the placebo group had a mean weight loss of 10.6 pounds. There was a significant time by treatment interaction (p=0.001), with the difference in weight between treatment groups being most pronounced after 6 weeks. Although overall QOL was similar in both arms of the study, several QOL subscale items did differ significantly. Compared to the placebo-treated patients, head-and-neck cancer patients in the MA arm reported the ability to eat as much as they liked (p=0.02 at 12 weeks), and lung cancer patients in the MA arm reported significantly better appetite at 4 weeks (p=0.03) and 8 weeks (p=0.001). Conclusion: MA used prophylactically is useful as an appetite stimulant; it can help patients maintain weight over the course of curative radiotherapy of the head and neck or lung and can improve specific aspects of QOL

  9. The head-mounted microscope.

    Science.gov (United States)

    Chen, Ting; Dailey, Seth H; Naze, Sawyer A; Jiang, Jack J

    2012-04-01

    Microsurgical equipment has greatly advanced since the inception of the microscope into the operating room. These advancements have allowed for superior surgical precision and better post-operative results. This study focuses on the use of the Leica HM500 head-mounted microscope for the operating phonosurgeon. The head-mounted microscope has an optical zoom from 2× to 9× and provides a working distance from 300 mm to 700 mm. The headpiece, with its articulated eyepieces, adjusts easily to head shape and circumference, and offers a focus function, which is either automatic or manually controlled. We performed five microlaryngoscopic operations utilizing the head-mounted microscope with successful results. By creating a more ergonomically favorable operating posture, a surgeon may be able to obtain greater precision and success in phonomicrosurgery. Phonomicrosurgery requires the precise manipulation of long-handled cantilevered instruments through the narrow bore of a laryngoscope. The head-mounted microscope shortens the working distance compared with a stand microscope, thereby increasing arm stability, which may improve surgical precision. Also, the head-mounted design permits flexibility in head position, enabling operator comfort, and delaying musculoskeletal fatigue. A head-mounted microscope decreases the working distance and provides better ergonomics in laryngoscopic microsurgery. These advances provide the potential to promote precision in phonomicrosurgery. Copyright © 2011 The American Laryngological, Rhinological, and Otological Society, Inc.

  10. Effect of head rotation in whiplash-type rear impacts.

    Science.gov (United States)

    Kumar, Shrawan; Ferrari, Robert; Narayan, Yogesh

    2005-01-01

    Knowledge is increasing about the electromyographic and kinematic response of the neck muscles to rear impact, and also recent information is available on the effect of a rear impact offset to the left (posterolateral). The effect of head rotation, however, at the time of rear impact is not known. The purpose of this study was to examine the effects of head rotation to the left and right on the cervical muscle response to increasing low-velocity posterolateral impacts. Twenty healthy volunteers were subjected to rear impacts of 4.7, 8.3, 10.9 and 13.7 m/s2 acceleration, offset by 45 degrees to the subject's left, with head rotation to right and left. Bilateral electromyograms of the sternocleidomastoids, trapezii and splenii capitis were recorded. Triaxial accelerometers recorded the acceleration of the sled, torso at the shoulder level, and head of the participant. With the head rotated to the right, at an acceleration of 13.7 m/s2, the left sternocleidomastoid generated 59% and the right sternocleidomastoid 20% of their maximal voluntary contraction (MVC) electromyogram (EMG). Under these conditions, the remaining muscles (both splenii capitis and trapezius) generated 25% or less of their MVC. With the head rotated to the left, at an acceleration of 13.7 m/s2, the right sternocleidomastoid generated 65% and the left sternocleidomastoid only 11% of the MVC EMG. Under these conditions, again the remaining muscles had low EMG activity (27% or less) with the exception of the left trapezius which generated 47% of its MVC. Electromyographic variables were significantly affected by the levels of acceleration (pfactor in determining the muscle response to whiplash, but head rotation at the time of impact is also important in this regard. More specifically, when a rear impact is left posterolateral, it results in increased EMG generation mainly in the contralateral sternocleidomastoid, as expected, but head rotation at the same time in this type of impact reduces the EMG

  11. Influence of arm positioning on tomographic thallium-201 myocardial perfusion imaging and the effect of attenuation correction

    International Nuclear Information System (INIS)

    Prvulovich, E.M.; Jarritt, P.H.; Vorontsova, E.; Bomanji, J.B.; Ell, P.J.

    2000-01-01

    Lateral attenuation in single-photon emission tomography (SPET) myocardial perfusion imaging (MPI) has been attributed to the left arm if it is held by the patient's side during data acquisition. As a result MPI data are conventionally acquired with the arms held above the head. The aims of this study were to determine the effect of imaging arms down on reconstructed tomographic images depicting regional myocardial thallium-201 distribution and to assess whether attenuation-corrected (AC) myocardial perfusion images acquired arms down could replace uncorrected (NC) images acquired arms up for routine clinical service. Twenty-eight patients referred for routine MPI underwent sequential 180 emission/transmission imaging for attenuation correction using an L-shaped dual-headed gamma camera (GE Optima) fitted with two gadolinium-153 scanning line sources. Delay data were acquired twice: once supine with the arms up and then supine with the arms down. Detector radius of rotation (ROR) for arms up and arms-down studies was recorded. For each data set, count density was measured in 17 segments of a polar plot and segmental uptake expressed relative to study maximum. Oblique images were assessed qualitatively by two observers blinded to study type for tracer distribution and overall quality. Transmission maps were assessed for truncation. Mean detector ROR was 190 mm for arms-up studies and 232 mm for arms-down studies (P 201 Tl distribution, particularly anterolaterally. There is lateral undercorrection in approximately 10% of AC arms-down studies, possibly because of attenuation map truncation. Image quality is reduced in about one-third of AC arms-down studies compared with NC arms-up studies. These data suggest that this attenuation correction method is not sufficiently robust to allow routine acquisition of MPI data with the arms down. (orig.)

  12. BreathSens: A Continuous On-Bed Respiratory Monitoring System With Torso Localization Using an Unobtrusive Pressure Sensing Array.

    Science.gov (United States)

    Liu, Jason J; Huang, Ming-Chun; Xu, Wenyao; Zhang, Xiaoyi; Stevens, Luke; Alshurafa, Nabil; Sarrafzadeh, Majid

    2015-09-01

    The ability to continuously monitor respiration rates of patients in homecare or in clinics is an important goal. Past research showed that monitoring patient breathing can lower the associated mortality rates for long-term bedridden patients. Nowadays, in-bed sensors consisting of pressure sensitive arrays are unobtrusive and are suitable for deployment in a wide range of settings. Such systems aim to extract respiratory signals from time-series pressure sequences. However, variance of movements, such as unpredictable extremities activities, affect the quality of the extracted respiratory signals. BreathSens, a high-density pressure sensing system made of e-Textile, profiles the underbody pressure distribution and localizes torso area based on the high-resolution pressure images. With a robust bodyparts localization algorithm, respiratory signals extracted from the localized torso area are insensitive to arbitrary extremities movements. In a study of 12 subjects, BreathSens demonstrated its respiratory monitoring capability with variations of sleep postures, locations, and commonly tilted clinical bed conditions.

  13. Probing muscle myosin motor action: x-ray (m3 and m6) interference measurements report motor domain not lever arm movement.

    Science.gov (United States)

    Knupp, Carlo; Offer, Gerald; Ranatunga, K W; Squire, John M

    2009-07-10

    The key question in understanding how force and movement are produced in muscle concerns the nature of the cyclic interaction of myosin molecules with actin filaments. The lever arm of the globular head of each myosin molecule is thought in some way to swing axially on the actin-attached motor domain, thus propelling the actin filament past the myosin filament. Recent X-ray diffraction studies of vertebrate muscle, especially those involving the analysis of interference effects between myosin head arrays in the two halves of the thick filaments, have been claimed to prove that the lever arm moves at the same time as the sliding of actin and myosin filaments in response to muscle length or force steps. It was suggested that the sliding of myosin and actin filaments, the level of force produced and the lever arm angle are all directly coupled and that other models of lever arm movement will not fit the X-ray data. Here, we show that, in addition to interference across the A-band, which must be occurring, the observed meridional M3 and M6 X-ray intensity changes can all be explained very well by the changing diffraction effects during filament sliding caused by heads stereospecifically attached to actin moving axially relative to a population of detached or non-stereospecifically attached heads that remain fixed in position relative to the myosin filament backbone. Crucially, and contrary to previous interpretations, the X-ray interference results provide little direct information about the position of the myosin head lever arm; they are, in fact, reporting relative motor domain movements. The implications of the new interpretation are briefly assessed.

  14. Body mapping of cutaneous wetness perception across the human torso during thermo-neutral and warm environmental exposures.

    Science.gov (United States)

    Filingeri, Davide; Fournet, Damien; Hodder, Simon; Havenith, George

    2014-10-15

    Sensing skin wetness is linked to inputs arising from cutaneous cold-sensitive afferents. As thermosensitivity to cold varies significantly across the torso, we investigated whether similar regional differences in wetness perception exist. We also investigated the regional differences in thermal pleasantness and whether these sensory patterns are influenced by ambient temperature. Sixteen males (20 ± 2 yr) underwent a quantitative sensory test under thermo-neutral [air temperature (Tair) = 22°C; relative humidity (RH) = 50%] and warm conditions (Tair = 33°C; RH = 50%). Twelve regions of the torso were stimulated with a dry thermal probe (25 cm(2)) with a temperature of 15°C below local skin temperature (Tsk). Variations in Tsk, thermal, wetness, and pleasantness sensations were recorded. As a result of the same cold-dry stimulus, the skin-cooling response varied significantly by location (P = 0.003). The lateral chest showed the greatest cooling (-5 ± 0.4°C), whereas the lower back showed the smallest (-1.9 ± 0.4°C). Thermal sensations varied significantly by location and independently from regional variations in skin cooling with colder sensations reported on the lateral abdomen and lower back. Similarly, the frequency of perceived skin wetness was significantly greater on the lateral and lower back as opposed to the medial chest. Overall wetness perception was slightly higher under warm conditions. Significantly more unpleasant sensations were recorded when the lateral abdomen and lateral and lower back were stimulated. We conclude that humans present regional differences in skin wetness perception across the torso, with a pattern similar to the regional differences in thermosensitivity to cold. These findings indicate the presence of a heterogeneous distribution of cold-sensitive thermo-afferent information. Copyright © 2014 the American Physiological Society.

  15. Role of UV light in photodamage, skin aging, and skin cancer: importance of photoprotection.

    Science.gov (United States)

    Gonzaga, Evelyn R

    2009-01-01

    Solar, and particularly UV, radiation causes molecular and cellular damage with resultant histopathologic and clinical degenerative changes, leading in turn to photosensitivity, photo-aging, and skin cancer. While our bodies have some natural UV defenses, additional protection from the sun is essential, including sun avoidance, physical protection, and sunscreen use. Sun avoidance includes limiting exposure during peak UV times (10am-4pm), avoiding UV-reflective surfaces such as sand, snow and water, and eliminating photosensitizing drugs. Physical protection includes wearing photoprotective clothing such as a broad-brimmed hat and long sleeves and use of UV-blocking films on windows. Sunscreen containing avobenzone, titanium dioxide, zinc oxide or encamsule should be used daily and frequently reapplied. To guard against the UVB spectrum, zinc oxide and titanium dioxide are particularly recommended. Sunscreen is generally under-applied at only 25% of the recommended dose, seriously compromising photoprotection. Dosage guidelines recommend using more than half a teaspoon each on head and neck area and each arm, and more than a teaspoon each on anterior torso, posterior torso, and each leg (approximately 2 mg/cm(2)).

  16. GPK heading machine

    Energy Technology Data Exchange (ETDEWEB)

    Krmasek, J.; Novosad, K.

    1981-01-01

    This article evaluates performance tests of the Soviet made GPK heading machine carried out in 4 coal mines in Czechoslovakia (Ostrava-Karvina region and Kladno mines). GPK works in coal seams and rocks with compression strength of 40 to 50 MPa. Dimensions of the tunnel are height 1.8 to 3.8 m and width 2.6 to 4.7 m, tunnel gradient plus to minus 10 degrees. GPK weighs 16 t, its conical shaped cutting head equipped with RKS-1 cutting tools is driven by an electric motor with 55 kW capacity. Undercarriage of the GPK, gathering-arm loader, hydraulic system, electric system and dust supression system (water spraying or pneumatic section) are characterized. Specifications of GPK heading machines are compared with PK-3r and F8 heading machines. Reliability, number of failures, dust level, noise, productivity depending on compression strength of rocks, heading rate in coal and in rocks, energy consumption, performance in inclined tunnels, and cutting tool wear are evaluated. Tests show that GPK can be used to drive tunnels in coal with rock constituting up to 50% of the tunnel crosscut, as long as rock compression strength does not exceed 50 MPa. In rocks characterized by higher compression strength cutting tool wear sharply increases. GPK is characterized by higher productivity than that of the PK-3r heading machine. Among the weak points of the GPK are: unsatisfactory reliability and excessive wear of its elements. (4 refs.) (In Czech)

  17. Behavioral effects of diazepam in the murine plus-maze: flumazenil antagonism of enhanced head dipping but not the disinhibition of open-arm avoidance.

    Science.gov (United States)

    Dalvi, A; Rodgers, R J

    1999-04-01

    Although it is widely believed that benzodiazepines reduce anxiety through positive allosteric modulation of the GABA(A)-chloride channel complex, this is not the only mechanism through which agents of this class can modify CNS function. Furthermore, a significant number of reports of apparent flumazenil blockade of diazepam anxiolysis in animal models have paid limited attention to possible intrinsic behavioral actions of the antagonist per se. In the present study, ethological methods were employed to assess in detail the effects of diazepam, flumazenil, and their combination on the behavior of male DBA/2 mice in the elevated plus-maze paradigm. In two experiments, diazepam (1.5 mg/kg) alone reduced open-arm avoidance and increased head dipping, whereas flumazenil (10-40 mg/kg) alone was without significant behavioral effect. However, with the sole exception of head dipping, prior administration of flumazenil (10 and 40 mg/kg) failed to block the behavioral effects of diazepam under present test conditions. These findings imply that the anxiolytic effects of diazepam in the mouse plus-maze are not mediated through flumazenil-sensitive benzodiazepine receptors and that alternate mechanisms must be considered.

  18. Sensory-Feedback Exoskeletal Arm Controller

    Science.gov (United States)

    An, Bin; Massie, Thomas H.; Vayner, Vladimir

    2004-01-01

    An electromechanical exoskeletal arm apparatus has been designed for use in controlling a remote robotic manipulator arm. The apparatus, called a force-feedback exoskeleton arm master (F-EAM) is comfortable to wear and easy to don and doff. It provides control signals from the wearer s arm to a robot arm or a computer simulator (e.g., a virtual-reality system); it also provides force and torque feedback from sensors on the robot arm or from the computer simulator to the wearer s arm. The F-EAM enables the wearer to make the robot arm gently touch objects and finely manipulate them without exerting excessive forces. The F-EAM features a lightweight design in which the motors and gear heads that generate force and torque feedback are made smaller than they ordinarily would be: this is achieved by driving the motors to power levels greater than would ordinarily be used in order to obtain higher torques, and by providing active liquid cooling of the motors to prevent overheating at the high drive levels. The F-EAM (see figure) includes an assembly that resembles a backpack and is worn like a backpack, plus an exoskeletal arm mechanism. The FEAM has five degrees of freedom (DOFs) that correspond to those of the human arm: 1. The first DOF is that of the side-to-side rotation of the upper arm about the shoulder (rotation about axis 1). The reflected torque for this DOF is provided by motor 1 via drum 1 and a planar four-bar linkage. 2. The second DOF is that of the up-and-down rotation of the arm about the shoulder. The reflected torque for this DOF is provided by motor 2 via drum 2. 3. The third DOF is that of twisting of the upper arm about its longitudinal axis. This DOF is implemented in a cable remote-center mechanism (CRCM). The reflected torque for this DOF is provided by motor 3, which drives the upper-arm cuff and the mechanism below it. A bladder inflatable by gas or liquid is placed between the cuff and the wearer s upper arm to compensate for misalignment

  19. Goniometer head

    International Nuclear Information System (INIS)

    Dzhazairov-Kakhramanov, V.; Berger, V.D.; Kadyrzhanov, K.K.; Zarifov, R.A.

    1994-01-01

    The goniometer head is an electromechanical instrument that performs the independent transfer of a testing sample on three coordinate axes (X, Y, Z) within limits of ±8 mm and independent rotation relative of these directions. The instrument comprises a sample holder, bellows component and three electrometer drives. The sample holder rotates around the axes X and Y, and is installed on the central arm which rotates around axis Z. One characteristic of this instrument is its independence which allows its use in any camera for researches in the field of radiation physics. 2 figs

  20. Randomized trial of opioids versus tricyclic antidepressants for radiation-induced mucositis pain in head and neck cancer

    Energy Technology Data Exchange (ETDEWEB)

    Ehrnrooth, E.; Grau, C.; Zachariae, R.; Andersen, Joern [Aarhus Univ. Hospital (Denmark). Dept. of Oncology

    2001-11-01

    Patients who receive radiotherapy for head and neck cancer are likely to develop painful mucositis. The pain is characterized by a burning or stinging sensation similar to neuropathic pain sensations. The purpose of the present study was to compare the analgesic effect of a tricyclic antidepressant (TC), commonly used in the treatment of neuropathic pain, with the effect of opioids on radiation-induced mucositis pain. Forty-three patients receiving 66-68 Gy external radiation according to the DAHANCA guidelines (the Danish Head and Neck Cancer Study Group) were randomized to either morphine or TC when mucositis pain was insufficiently managed with weak analgesics. Patients with insufficient pain control in either treatment arm received supplementary medication from the opposite treatment arm. Pain was evaluated weekly using a VAS scale and the McGill Pain Questionnaire. The degree of mucositis and the degree of depression were measured at the same time intervals. Twenty-two patients entered the opioid arm and 21 the TC arm. Two patients in each arm were non-evaluable. VAS pain scores were significantly reduced in the opioid treatment arm one week after randomization (p=0.01). Eight patients in the TC arm were managed with TC alone, but for 11 patients it was necessary to add morphine. The 20 evaluable patients in the morphine arm required no additional treatment. There were no significant differences in side effects between the two groups. Higher pain scores in the TC arm, but not in the opioid arm, were significantly correlated with higher BDI scores. Some head and neck cancer patients with radiation-induced nucositis pain may have sufficient pain control on TC alone. This might be useful in patients with relative counter-indications to opioid treatment.

  1. Randomized trial of opioids versus tricyclic antidepressants for radiation-induced mucositis pain in head and neck cancer

    International Nuclear Information System (INIS)

    Ehrnrooth, E.; Grau, C.; Zachariae, R.; Andersen, Joern

    2001-01-01

    Patients who receive radiotherapy for head and neck cancer are likely to develop painful mucositis. The pain is characterized by a burning or stinging sensation similar to neuropathic pain sensations. The purpose of the present study was to compare the analgesic effect of a tricyclic antidepressant (TC), commonly used in the treatment of neuropathic pain, with the effect of opioids on radiation-induced mucositis pain. Forty-three patients receiving 66-68 Gy external radiation according to the DAHANCA guidelines (the Danish Head and Neck Cancer Study Group) were randomized to either morphine or TC when mucositis pain was insufficiently managed with weak analgesics. Patients with insufficient pain control in either treatment arm received supplementary medication from the opposite treatment arm. Pain was evaluated weekly using a VAS scale and the McGill Pain Questionnaire. The degree of mucositis and the degree of depression were measured at the same time intervals. Twenty-two patients entered the opioid arm and 21 the TC arm. Two patients in each arm were non-evaluable. VAS pain scores were significantly reduced in the opioid treatment arm one week after randomization (p=0.01). Eight patients in the TC arm were managed with TC alone, but for 11 patients it was necessary to add morphine. The 20 evaluable patients in the morphine arm required no additional treatment. There were no significant differences in side effects between the two groups. Higher pain scores in the TC arm, but not in the opioid arm, were significantly correlated with higher BDI scores. Some head and neck cancer patients with radiation-induced nucositis pain may have sufficient pain control on TC alone. This might be useful in patients with relative counter-indications to opioid treatment

  2. Calcium sensors of ciliary outer arm dynein: functions and phylogenetic considerations for eukaryotic evolution.

    Science.gov (United States)

    Inaba, Kazuo

    2015-01-01

    The motility of eukaryotic cilia and flagella is modulated in response to several extracellular stimuli. Ca(2+) is the most critical intracellular factor for these changes in motility, directly acting on the axonemes and altering flagellar asymmetry. Calaxin is an opisthokont-specific neuronal calcium sensor protein first described in the sperm of the ascidian Ciona intestinalis. It binds to a heavy chain of two-headed outer arm dynein in a Ca(2+)-dependent manner and regulates 'asymmetric' wave propagation at high concentrations of Ca(2+). A Ca(2+)-binding subunit of outer arm dynein in Chlamydomonas reinhardtii, the light chain 4 (LC4), which is a Ca(2+)-sensor phylogenetically different from calaxin, shows Ca(2+)-dependent binding to a heavy chain of three-headed outer arm dynein. However, LC4 appears to participate in 'symmetric' wave propagation at high concentrations of Ca(2+). LC4-type dynein light chain is present in bikonts, except for some subclasses of the Excavata. Thus, flagellar asymmetry-symmetry conversion in response to Ca(2+) concentration represents a 'mirror image' relationship between Ciona and Chlamydomonas. Phylogenetic analyses indicate the duplication, divergence, and loss of heavy chain and Ca(2+)-sensors of outer arm dynein among excavate species. These features imply a divergence point with respect to Ca(2+)-dependent regulation of outer arm dynein in cilia and flagella during the evolution of eukaryotic supergroups.

  3. When dynamic, the head and face alone can express pride.

    Science.gov (United States)

    Nelson, Nicole L; Russell, James A

    2011-08-01

    Prior research suggested that pride is recognized only when a head and facial expression (e.g., tilted head with a slight smile) is combined with a postural expression (e.g., expanded body and arm gestures). However, these studies used static photographs. In the present research, participants labeled the emotion conveyed by four dynamic cues to pride, presented as video clips: head and face alone, body posture alone, voice alone, and an expression in which head and face, body posture, and voice were presented simultaneously. Participants attributed pride to the head and face alone, even when postural or vocal information was absent. Pride can be conveyed without body posture or voice. 2011 APA, all rights reserved

  4. Measurements of surgeons' exposure to ionizing radiation dose during intraoperative use of C-arm fluoroscopy.

    Science.gov (United States)

    Lee, Kisung; Lee, Kyoung Min; Park, Moon Seok; Lee, Boram; Kwon, Dae Gyu; Chung, Chin Youb

    2012-06-15

    Measurement of radiation dose from C-arm fluoroscopy during a simulated intraoperative use in spine surgery. OBJECTIVE.: To investigate scatter radiation doses to specific organs of surgeons during intraoperative use of C-arm fluoroscopy in spine surgery and to provide practical intraoperative guidelines. There have been studies that reported the radiation dose of C-arm fluoroscopy in various procedures. However, radiation doses to surgeons' specific organs during spine surgery have not been sufficiently examined, and the practical intraoperative radioprotective guidelines have not been suggested. Scatter radiation dose (air kerma rate) was measured during the use of a C-arm on an anthropomorphic chest phantom on an operating table. Then, a whole body anthropomorphic phantom was located besides the chest phantom to simulate a surgeon, and scatter radiation doses to specific organs (eye, thyroid, breast, and gonads) and direct radiation dose to the surgeon's hand were measured using 4 C-arm configurations (standard, inverted, translateral, and tube translateral). The effects of rotating the surgeon's head away from the patient and of a thyroid shield were also evaluated. Scatter radiation doses decreased as distance from the patient increased during C-arm fluoroscopy use. The standard and translateral C-arm configurations caused lower scatter doses to sensitive organs than inverted and tube translateral configurations. Scatter doses were highest for breast and lowest for gonads. The use of a thyroid shield and rotating the surgeon's head away from the patient reduced scatter radiation dose to the surgeon's thyroid and eyes. The direct radiation dose was at least 20 times greater than scatter doses to sensitive organs. The following factors could reduce radiation exposure during intraoperative use of C-arm; (1) distance from the patient, (2) C-arm configuration, (3) radioprotective equipments, (4) rotating the surgeons' eyes away from the patient, and (5) avoiding

  5. Comparative Assessment of Torso and Seat Mounted Restraint Systems using Manikins on the Vertical Deceleration Tower

    Science.gov (United States)

    2017-03-01

    AFRL-RH-WP-TR-2017-0044 Comparative Assessment of Torso and Seat Mounted Restraint Systems using Manikins on the Vertical ...Restraint Systems using Manikins on the Vertical Deceleration Tower 5a. CONTRACT NUMBER FA8650-14-D-6500-0001 5b. GRANT NUMBER 5c. PROGRAM...experimental effort involving a series of +z-axis impact tests was conducted on the 711th Human Performance Wing’s Vertical Deceleration Tower (VDT

  6. What is the best position of the arms in mantle field for Hodgkin's disease?

    International Nuclear Information System (INIS)

    Pergolizzi, Stefano; Settineri, Nicola; Gaeta, Michele; Scribano, Emanuele; Santacaterina, Anna; Ascenti, Giorgio; Frosina, Pasquale; De Renzis, Costantino

    2000-01-01

    Purpose: To evaluate the best position of the arms in mantle field for Hodgkin's disease. Methods and Materials: In 12 patients, with surgical clips placed at the time of an axillary dissection for breast cancer, the radiological projection of the clips according to three arm positions was prospectively evaluated: akimbo (A), extended (E), and up over the head (U). The surgical clips were arbitrarily separated into two groups: lower and upper. In each patient, the distance between the surgical clips and chest wall was measured, and the possibility of shielding the lungs and humeral heads was evaluated. Results: The mean displacement of the lower clips away from the chest wall when the patients were in A, E, and U positions was 2.5, 3.0, and 4.6 cm, respectively. The upper group clips showed a lower difference in distance from chest wall. In the U position, there was always a clip of the lower group that projected over the humeral head, making it impossible to block this structure. Conclusion: In the A position, there is the possibility of blocking the humeral head, but it is necessary to irradiate more lung parenchyma. Type E treatment setup allows the shielding of both lung and humeral head, while maintaining adequate margins around the axillary nodes. In the U position, there is a greater possibility of shielding the lung parenchyma, but it is impossible to block the humeral heads

  7. Wound Ballistics Modeling for Blast Loading Blunt Force Impact and Projectile Penetration.

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, Paul A. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)

    2015-11-01

    Light body armor development for the warfighter is based on trial-and-error testing of prototype designs against ballistic projectiles. Torso armor testing against blast is nonexistent but necessary to protect the heart and lungs. In tests against ballistic projectiles, protective apparel is placed over ballistic clay and the projectiles are fired into the armor/clay target. The clay represents the human torso and its behind-armor, permanent deflection is the principal metric used to assess armor protection. Although this approach provides relative merit assessment of protection, it does not examine the behind-armor blunt trauma to crucial torso organs. We propose a modeling and simulation (M&S) capability for wound injury scenarios to the head, neck, and torso of the warfighter. We will use this toolset to investigate the consequences of, and mitigation against, blast exposure, blunt force impact, and ballistic projectile penetration leading to damage of critical organs comprising the central nervous, cardiovascular, and respiratory systems. We will leverage Sandia codes and our M&S expertise on traumatic brain injury to develop virtual anatomical models of the head, neck, and torso and the simulation methodology to capture the physics of wound mechanics. Specifically, we will investigate virtual wound injuries to the head, neck, and torso without and with protective armor to demonstrate the advantages of performing injury simulations for the development of body armor. The proposed toolset constitutes a significant advance over current methods by providing a virtual simulation capability to investigate wound injury and optimize armor design without the need for extensive field testing.

  8. Automated segmentation and recognition of abdominal wall muscles in X-ray torso CT images and its application in abdominal CAD

    International Nuclear Information System (INIS)

    Zhou, X.; Kamiya, N.; Hara, T.; Fujita, H.; Chen, H.; Yokoyama, R.; Hoshi, H.

    2007-01-01

    The information of abdominal wall is very important for the planning of surgical operation and abdominal organ recognition. In research fields of computer assisted radiology and surgery and computer-aided diagnosis, the segmentation and recognition of the abdominal wall muscles in CT images is a necessary pre-processing step. Due to the complexity of the abdominal wall structure and indistinctive in CT images, the automated segmentation of abdominal wall muscles is a difficult issue and has not been solved completely. We propose an approach to segment the abdominal wall muscles and divide it into three categories (front abdominal muscles including rectus abdominis; left and right side abdominal muscles including external oblique, internal oblique and transversus abdominis muscles) automatically. The approach, first, makes an initial classification of bone, fat, and muscles and organs based on the CT number. Then a layer structure is generated to describe the 3-D anatomical structures of human torso by stretching the torso region onto a thin-plate for easy recognition. The abdominal wall muscles are recognized on the layer structures using the spatial relations to the skeletal structure and CT numbers. Finally, the recognized regions are mapped back to the 3-D CT images using an inverse transformation of the stretching process. This method is applied to 20 cases of torso CT images and evaluations are based on visual comparison of the recognition results and the original CT images by an expert in anatomy. The results show that our approach can segment and recognize abdominal wall muscle regions effectively. (orig.)

  9. Mid-upper arm circumference in pregnant women and its relation to birth weight

    Directory of Open Access Journals (Sweden)

    Ricalde Anamaría E.

    1998-01-01

    Full Text Available OBJECTIVE: In order to determine the relationship between some maternal anthropometric indicators and birth weight, crown-heel length and newborn's head circumference, 92 pregnant women were followed through at the prenatal service of hospital in S. Paulo, Brazil. MATERIAL AND METHOD: The following variables were established for the mother: weight, height, mid-upper arm circumference, pre-pregnancy weight, gestational weight gain and Quetelet's index. For the newborn the following variables were recorded: birth weight, crown-heel length, head circumference and gestational age by Dubowitz's method. RESULTS: Significant associations were noted between gestational age and newborn variables. In addition, maternal mid-arm circumference (MUAC and pre-pregnancy weight were found to be positively correlated to birth weight (r=0.399; r=0.378, respectively. The multivariate linear regression shows that gestational age, mother's arm circumference and pre-pregnancy weight continue to be significant predictors of birth weight. On the other hand, only gestational age and mother's age was associated with crown-heel length. Similarly MUAC was significantly associated with crown-heel length (r= 0.306; P=0.0030. CONCLUSION: Maternal mid-upper arm circumference is a potential indicator of maternal nutritional status. It could be used in association with other anthropometric measurements, instead of pre-pregnancy weight, as an alternative indicator to assess women at risk of poor pregnancy outcome.

  10. Mid-upper arm circumference in pregnant women and its relation to birth weight

    Directory of Open Access Journals (Sweden)

    Anamaría E. Ricalde

    1998-04-01

    Full Text Available OBJECTIVE: In order to determine the relationship between some maternal anthropometric indicators and birth weight, crown-heel length and newborn's head circumference, 92 pregnant women were followed through at the prenatal service of hospital in S. Paulo, Brazil. MATERIAL AND METHOD: The following variables were established for the mother: weight, height, mid-upper arm circumference, pre-pregnancy weight, gestational weight gain and Quetelet's index. For the newborn the following variables were recorded: birth weight, crown-heel length, head circumference and gestational age by Dubowitz's method. RESULTS: Significant associations were noted between gestational age and newborn variables. In addition, maternal mid-arm circumference (MUAC and pre-pregnancy weight were found to be positively correlated to birth weight (r=0.399; r=0.378, respectively. The multivariate linear regression shows that gestational age, mother's arm circumference and pre-pregnancy weight continue to be significant predictors of birth weight. On the other hand, only gestational age and mother's age was associated with crown-heel length. Similarly MUAC was significantly associated with crown-heel length (r= 0.306; P=0.0030. CONCLUSION: Maternal mid-upper arm circumference is a potential indicator of maternal nutritional status. It could be used in association with other anthropometric measurements, instead of pre-pregnancy weight, as an alternative indicator to assess women at risk of poor pregnancy outcome.

  11. Coupled lattice Boltzmann method for numerical simulations of fully coupled heart and torso bidomain system in electrocardiology

    OpenAIRE

    Corre , Samuel; Belmiloudi , Aziz

    2016-01-01

    International audience; In this work, a modified coupling Lattice Boltzmann Model (LBM) in simulation of cardiac electrophysiology is developed in order to capture the detailed activities of macro- to micro-scale transport processes. The propagation of electrical activity in the human heart through torso is mathematically modeled by bidomain type systems. As transmembrane potential evolves, we take into account domain anisotropical properties using intracellular and extracellular conductivity...

  12. SMC Progressively Aligns Chromosomal Arms in Caulobacter crescentus but Is Antagonized by Convergent Transcription

    Directory of Open Access Journals (Sweden)

    Ngat T. Tran

    2017-08-01

    Full Text Available The structural maintenance of chromosomes (SMC complex plays an important role in chromosome organization and segregation in most living organisms. In Caulobacter crescentus, SMC is required to align the left and the right arms of the chromosome that run in parallel down the long axis of the cell. However, the mechanism of SMC-mediated alignment of chromosomal arms remains elusive. Here, using genome-wide methods and microscopy of single cells, we show that Caulobacter SMC is recruited to the centromeric parS site and that SMC-mediated arm alignment depends on the chromosome-partitioning protein ParB. We provide evidence that SMC likely tethers the parS-proximal regions of the chromosomal arms together, promoting arm alignment. Furthermore, we show that highly transcribed genes near parS that are oriented against SMC translocation disrupt arm alignment, suggesting that head-on transcription interferes with SMC translocation. Our results demonstrate a tight interdependence of bacterial chromosome organization and global patterns of transcription.

  13. The influence of whole-body vs. torso pre-cooling on physiological strain and performance of high-intensity exercise in the heat.

    Science.gov (United States)

    Sleivert, G G; Cotter, J D; Roberts, W S; Febbraio, M A

    2001-04-01

    Little research has been reported examining the effects of pre-cooling on high-intensity exercise performance, particularly when combined with strategies to keep the working muscle warm. This study used nine active males to determine the effects of pre-cooling the torso and thighs (LC), pre-cooling the torso (ice-vest in 3 degrees C air) while keeping the thighs warm (LW), or no cooling (CON: 31 degrees C air), on physiological strain and high-intensity (45-s) exercise performance (33 degrees C, 60% rh). Furthermore, we sought to determine whether performance after pre-cooling was influenced by a short exercise warm-up. The 45-s test was performed at different (PForearm blood flow prior to exercise was also lower in LC (3.1+/-2.0 ml 100 ml tissue(-1) x min(-1)) than CON (8.2+/-2.5, P=0.01) but not LW (4.3+/-2.6, P=0.46). After an exercise warm-up, muscle temperature (Tm) was not significantly different between conditions (CON: 37.3+/-1.5, LW: 37.3+/-1.2, LC: 36.6+/-0.7 degrees C, P=0.16) but when warm-up was excluded, T(m) was lower in LC (34.5+/-1.9 degrees C, P=0.02) than in CON (37.3+/-1.0) and LW (37.1+/-0.9). Even when a warm-up was performed, torso+thigh pre-cooling decreased both peak (-3.4+/-3.8%, P=0.04) and mean power output (-4.1+/-3.8%, P=0.01) relative to the control, but this effect was markedly larger when warm-up was excluded (peak power -7.7+/-2.5%, P=0.01; mean power -7.6+/-1.2%, P=0.01). Torso-only pre-cooling did not reduce peak or mean power, either with or without warm-up. These data indicate that pre-cooling does not improve 45-s high-intensity exercise performance, and can impair performance if the working muscles are cooled. A short exercise warm-up largely removes any detrimental effects of a cold muscle on performance by increasing Tm.

  14. Unilateral variant motor innervations of flexure muscles of arm

    Directory of Open Access Journals (Sweden)

    A S Yogesh

    2010-01-01

    Full Text Available The musculocutaneous nerve usually branches out from the lateral cord of brachial plexus. It innervates the corcobrachialis, biceps brachii and brachialis muscles and continues as the lateral cutaneous nerve of forearm without exhibiting any communication with the median nerve or any other nerve. We report unilateral variation in motor innervations of the left arm in a 58-year-old male cadaver. The musculocutaneous nerve was found to be absent. A muscular branch of the median nerve was supplying the coracobrachialis muscle. In the middle of arm, the median nerve was found to be branching out, bifurcating and supplying the long and short head of biceps. The median nerve was found to be giving a separate branch, which supplied the brachialis muscle and continued as the lateral cutaneous nerve of forearm. The right sided structures were found to be normal. Surgeons should keep such variations in mind while performing arm surgeries.

  15. Predictors of Intrathoracic Injury after Blunt Torso Trauma in Children Presenting to an Emergency Department as Trauma Activations.

    Science.gov (United States)

    McNamara, Caitlin; Mironova, Irina; Lehman, Erik; Olympia, Robert P

    2017-06-01

    Thoracic injuries are a major cause of death associated with blunt trauma in children. Screening for injury with chest x-ray study, compared with chest computed tomography (CT) scan, has been controversial, weighing the benefits of specificity with the detriment of radiation exposure. To identify predictors of thoracic injury in children presenting as trauma activations to a Level I trauma center after blunt torso trauma, and to compare these predictors with those previously reported in the literature. We performed a retrospective chart review of pediatric patients (trauma center between June 2010 and June 2013 as a trauma activation after sustaining a blunt torso trauma and who received diagnostic imaging of the chest as part of their initial evaluation. Data analysis was performed on 166 patients. There were 33 patients (20%) with 45 abnormalities detected on diagnostic imaging of the chest, with the most common abnormalities being lung contusion (36%), pneumothorax (22%), and rib fracture (13%). Statistically significant predictors of abnormal diagnostic imaging of the chest included Glasgow Coma Scale score (GCS) trauma include GCS < 15, hypoxia, syncope/dizziness, cervical spine tenderness, thoraco-lumbar-sacral spine tenderness, and abdominal/pelvic tenderness. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Toward anthropomimetic robotics: development, simulation, and control of a musculoskeletal torso.

    Science.gov (United States)

    Wittmeier, Steffen; Alessandro, Cristiano; Bascarevic, Nenad; Dalamagkidis, Konstantinos; Devereux, David; Diamond, Alan; Jäntsch, Michael; Jovanovic, Kosta; Knight, Rob; Marques, Hugo Gravato; Milosavljevic, Predrag; Mitra, Bhargav; Svetozarevic, Bratislav; Potkonjak, Veljko; Pfeifer, Rolf; Knoll, Alois; Holland, Owen

    2013-01-01

    Anthropomimetic robotics differs from conventional approaches by capitalizing on the replication of the inner structures of the human body, such as muscles, tendons, bones, and joints. Here we present our results of more than three years of research in constructing, simulating, and, most importantly, controlling anthropomimetic robots. We manufactured four physical torsos, each more complex than its predecessor, and developed the tools required to simulate their behavior. Furthermore, six different control approaches, inspired by classical control theory, machine learning, and neuroscience, were developed and evaluated via these simulations or in small-scale setups. While the obtained results are encouraging, we are aware that we have barely exploited the potential of the anthropomimetic design so far. But, with the tools developed, we are confident that this novel approach will contribute to our understanding of morphological computation and human motor control in the future.

  17. Whole-body CT in polytrauma patients: the effect of arm position on abdominal image quality when using a human phantom

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Pil-Hyun [Yonsei University, Wonju (Korea, Republic of); Wonju Christian Hospital, Wonju (Korea, Republic of); Kim, Hee-Joung; Lee, Chang-Lae; Kim, Dae-Hong [Yonsei University, Wonju (Korea, Republic of); Lee, Won-Hyung; Jeon, Sung-Su [Wonju Christian Hospital, Wonju (Korea, Republic of)

    2012-06-15

    For a considerable number of emergency computed tomography (CT) scans, patients are unable to position their arms above their head due to traumatic injuries. The arms-down position has been shown to reduce image quality with beam-hardening artifacts in the dorsal regions of the liver, spleen, and kidneys, rendering these images non-diagnostic. The purpose of this study was to evaluate the effect of arm position on the image quality in patients undergoing whole-body CT. We acquired CT scans with various acquisition parameters at voltages of 80, 120, and 140 kVp and an increasing tube current from 200 to 400 mAs in 50 mAs increments. The image noise and the contrast assessment were considered for quantitative analyses of the CT images. The image noise (IN), the contrast-to-noise ratio (CNR), the signal-to-noise ratio (SNR), and the coefficient of variation (COV) were evaluated. Quantitative analyses of the experiments were performed with CT scans representative of five different arm positions. Results of the CT scans acquired at 120 kVp and 250 mAs showed high image quality in patients with both arms raised above the head (SNR: 12.4, CNR: 10.9, and COV: 8.1) and both arms flexed at the elbows on the chest (SNR: 11.5, CNR: 10.2, and COV: 8.8) while the image quality significantly decreased with both arms in the down position (SNR: 9.1, CNR: 7.6, and COV: 11). Both arms raised, one arm raised, and both arms flexed improved the image quality compared to arms in the down position by reducing beam-hardening and streak artifacts caused by the arms being at the side of body. This study provides optimal methods for achieving higher image quality and lower noise in abdominal CT for trauma patients.

  18. Whole-body CT in polytrauma patients: The effect of arm position on abdominal image quality when using a human phantom

    Science.gov (United States)

    Jeon, Pil-Hyun; Kim, Hee-Joung; Lee, Chang-Lae; Kim, Dae-Hong; Lee, Won-Hyung; Jeon, Sung-Su

    2012-06-01

    For a considerable number of emergency computed tomography (CT) scans, patients are unable to position their arms above their head due to traumatic injuries. The arms-down position has been shown to reduce image quality with beam-hardening artifacts in the dorsal regions of the liver, spleen, and kidneys, rendering these images non-diagnostic. The purpose of this study was to evaluate the effect of arm position on the image quality in patients undergoing whole-body CT. We acquired CT scans with various acquisition parameters at voltages of 80, 120, and 140 kVp and an increasing tube current from 200 to 400 mAs in 50 mAs increments. The image noise and the contrast assessment were considered for quantitative analyses of the CT images. The image noise (IN), the contrast-to-noise ratio (CNR), the signal-to-noise ratio (SNR), and the coefficient of variation (COV) were evaluated. Quantitative analyses of the experiments were performed with CT scans representative of five different arm positions. Results of the CT scans acquired at 120 kVp and 250 mAs showed high image quality in patients with both arms raised above the head (SNR: 12.4, CNR: 10.9, and COV: 8.1) and both arms flexed at the elbows on the chest (SNR: 11.5, CNR: 10.2, and COV: 8.8) while the image quality significantly decreased with both arms in the down position (SNR: 9.1, CNR: 7.6, and COV: 11). Both arms raised, one arm raised, and both arms flexed improved the image quality compared to arms in the down position by reducing beam-hardening and streak artifacts caused by the arms being at the side of body. This study provides optimal methods for achieving higher image quality and lower noise in abdominal CT for trauma patients.

  19. Whole-body CT in polytrauma patients: the effect of arm position on abdominal image quality when using a human phantom

    International Nuclear Information System (INIS)

    Jeon, Pil-Hyun; Kim, Hee-Joung; Lee, Chang-Lae; Kim, Dae-Hong; Lee, Won-Hyung; Jeon, Sung-Su

    2012-01-01

    For a considerable number of emergency computed tomography (CT) scans, patients are unable to position their arms above their head due to traumatic injuries. The arms-down position has been shown to reduce image quality with beam-hardening artifacts in the dorsal regions of the liver, spleen, and kidneys, rendering these images non-diagnostic. The purpose of this study was to evaluate the effect of arm position on the image quality in patients undergoing whole-body CT. We acquired CT scans with various acquisition parameters at voltages of 80, 120, and 140 kVp and an increasing tube current from 200 to 400 mAs in 50 mAs increments. The image noise and the contrast assessment were considered for quantitative analyses of the CT images. The image noise (IN), the contrast-to-noise ratio (CNR), the signal-to-noise ratio (SNR), and the coefficient of variation (COV) were evaluated. Quantitative analyses of the experiments were performed with CT scans representative of five different arm positions. Results of the CT scans acquired at 120 kVp and 250 mAs showed high image quality in patients with both arms raised above the head (SNR: 12.4, CNR: 10.9, and COV: 8.1) and both arms flexed at the elbows on the chest (SNR: 11.5, CNR: 10.2, and COV: 8.8) while the image quality significantly decreased with both arms in the down position (SNR: 9.1, CNR: 7.6, and COV: 11). Both arms raised, one arm raised, and both arms flexed improved the image quality compared to arms in the down position by reducing beam-hardening and streak artifacts caused by the arms being at the side of body. This study provides optimal methods for achieving higher image quality and lower noise in abdominal CT for trauma patients.

  20. Fabrication of a set of realistic torso phantoms for calibration of transuranic nuclide lung counting facilities

    International Nuclear Information System (INIS)

    Griffith, R.V.; Anderson, A.L.; Sundbeck, C.W.; Alderson, S.W.

    1983-01-01

    A set of 16 tissue equivalent torso phantoms has been fabricated for use by major laboratories involved in counting transuranic nuclides in the lung. These phantoms, which have bone equivalent plastic rib cages, duplicate the performance of the DOE Realistic Phantom set. The new phantoms (and their successors) provide the user laboratories with a highly realistic calibration tool. Moreover, use of these phantoms will allow participating laboratories to intercompare calibration information, both on formal and informal bases. 3 refs., 2 figs

  1. Clinical implementation of intraoperative cone-beam CT in head and neck surgery

    Science.gov (United States)

    Daly, M. J.; Chan, H.; Nithiananthan, S.; Qiu, J.; Barker, E.; Bachar, G.; Dixon, B. J.; Irish, J. C.; Siewerdsen, J. H.

    2011-03-01

    A prototype mobile C-arm for cone-beam CT (CBCT) has been translated to a prospective clinical trial in head and neck surgery. The flat-panel CBCT C-arm was developed in collaboration with Siemens Healthcare, and demonstrates both sub-mm spatial resolution and soft-tissue visibility at low radiation dose (e.g., software based on the open-source Image-Guided Surgery Toolkit (IGSTK). The CBCT C-arm has been successfully deployed in 15 head and neck cases and streamlined into the surgical environment using human factors engineering methods and expert feedback from surgeons, nurses, and anesthetists. Intraoperative imaging is implemented in a manner that maintains operating field sterility, reduces image artifacts (e.g., carbon fiber OR table) and minimizes radiation exposure. Image reviews conducted with surgical staff indicate bony detail and soft-tissue visualization sufficient for intraoperative guidance, with additional artifact management (e.g., metal, scatter) promising further improvements. Clinical trial deployment suggests a role for intraoperative CBCT in guiding complex head and neck surgical tasks, including planning mandible and maxilla resection margins, guiding subcranial and endonasal approaches to skull base tumours, and verifying maxillofacial reconstruction alignment. Ongoing translational research into complimentary image-guidance subsystems include novel methods for real-time tool tracking, fusion of endoscopic video and CBCT, and deformable registration of preoperative volumes and planning contours with intraoperative CBCT.

  2. The effect of delayed postoperative irradiation on local control of soft tissue sarcomas of the extremity and torso

    International Nuclear Information System (INIS)

    Schwartz, David L.; Einck, John; Hunt, Karen; Bruckner, James; Conrad, Ernest; Koh, W.-J.; Laramore, George E.

    2002-01-01

    Purpose: The impact of delayed adjuvant radiotherapy in patients treated by surgical resection for peripheral or torso soft tissue sarcoma has not been well characterized. We retrospectively examined this issue in an institutional patient cohort. Methods and Materials: One hundred two adult patients were treated at the University of Washington Medical Center between 1981 and 1998 with postoperative radiotherapy for cure of a newly diagnosed soft tissue sarcoma. Of this group, 58 patients had primary intermediate- or high-grade disease of the extremity or torso (50 extremity/8 torso). Tumor histology was predominantly malignant fibrohistiocytoma, synovial cell sarcoma, and leiomyosarcoma. The group was dichotomized according to time interval from definitive resection to the start of adjuvant radiation. Twenty-six patients had a short delay, defined as <4 months, and 32 patients had a long delay of ≥4 months. Both groups were balanced with regard to site, size, margin status, and tumor depth; however, the long-delay group had a larger proportion of high histologic grade lesions and was treated more frequently with chemotherapy (31/32 [97%] for long-delay patients vs. 14/26 [54%] for short-delay patients). Median follow-up was 49.5 months (range: 7-113 months). Median follow-up for patients still alive was 54 months (range: 9-113 months). Survival outcomes were estimated by the Kaplan-Meier method. Results: Overall local relapse-free survival at 5 years from the time of definitive resection was 74%. On univariate analysis, estimated 5-year local relapse-free survival was significantly improved in the short-delay group (88% vs. 62% for the long-delay group, p = 0.048 by log rank). Overall distant relapse-free survival, disease-free survival, and overall survival at 5 years were 77%, 68%, and 86%, respectively. These survival outcomes were statistically equivalent in both radiation delay groups. There was no evidence to suggest that delaying adjuvant systemic therapy

  3. A structural comparison of female-male and female-female mounting in Japanese macaques (Macaca fuscata).

    Science.gov (United States)

    Ottenheimer Carrier, Lydia; Leca, Jean-Baptiste; Pellis, Sergio; Vasey, Paul L

    2015-10-01

    In certain populations, female Japanese macaques (Macaca fuscata) mount both males and females. Vasey (2007) proposed that female-female sexual mounting in Japanese macaques may be a neutral evolutionary by-product of a purported adaptation, namely, female-male mounting. In this study, we aim to further examine the proposed link between female-male and female-female mounting in Japanese macaques by comparing the structural characteristics that define both forms of mounting. We do so using Eshkol-Wachman Movement Notation (EWMN), a globographic reference system that can be used to describe the position of body segments. No significant differences were observed in the female mounters' positioning of eight different body segments (i.e., lower torso, mid-torso, upper torso, upper arm, lower arm, upper leg, lower leg, and foot) during female-male and female-female mounting. This finding lends support to the conclusion that female-female and female-male mounting are structurally, and thus, evolutionarily, related. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Interruptions in Chest Compressions by Surf Lifeguards: A Comparison of Face-mask Ventilation in Over-the-head CPR vs Standard CPR

    DEFF Research Database (Denmark)

    Nørkjær, Louise; Nielsen, Lars Henrik; Bomholt, Katrine Bjørnshave

    . The International Life Saving Federation recommends CPR using face-mask ventilation. It is currently unknown if OH-CPR using face-mask ventilation improves CPR quality. We hypothesized that OH-CPR is superior to standard CPR with face-mask ventilation among surf lifeguards. Methods: Surf lifeguards were trained......Introduction: Ventilation is a priority in drowning resuscitation. Over-the-head CPR (OH-CPR), i.e. with the rescuer located at the top of the victim’s head instead of alongside the victim’s torso, has been demonstrated to be superior when doing bag-valve-mask ventilation compared to standard CPR...... in OH-CPR and standard CPR with face-mask ventilation and randomized to a crossover comparison on a manikin. CPR quality data were obtained from the manikin and video recordings. Interruptions in chest compressions were used as a primary measure of CPR quality. A sample size of 14 participants...

  5. Motorized dirt bike injuries in children.

    Science.gov (United States)

    Ramakrishnaiah, Raghu H; Shah, Chetan; Parnell-Beasley, Donna; Greenberg, Bruce S

    2013-04-01

    The number of dirt bike injuries in children in the United States is increasing and poses a public health problem. The purpose of our study was to identify the imaging patterns of dirt bike injuries in children and associations with morbidity and mortality. The study included 85 children (83 boys, 2 girls) dirt bike injury treated at a tertiary care pediatric hospital. Imaging studies and hospital medical records were reviewed. Outcomes were classified into the following categories: short-term disability, long-term disability or no follow-up available. Imaging studies were reviewed for head, torso, and extremity injuries. One-tailed z test for two proportions was used to determine significant differences between various proportions. Chi-square test with Yates correction was used to determine the significance of long-term disability with injury type. Long bone fractures were the most common injuries. Lower extremity fractures accounted for 79% of extremity fractures and were significantly more common than upper extremity fractures (p = 0.001). Head injuries included fractures (n = 9), brain contusion (n = 5), and meningeal hemorrhage (n = 2). Head injury was associated with long-term disability (p < 0.0001). All torso injuries were solitary. Long-term disability was associated with head injuries but not with torso or extremity injuries. Lower extremity injuries were significantly more common than upper extremity injuries. Torso solid organ injuries were uniformly solitary. Published by Elsevier Inc.

  6. Realistic torso phantom for calibration of in-vivo transuranic-nuclide counting facilities

    Energy Technology Data Exchange (ETDEWEB)

    Shirotani, Takashi

    1988-11-01

    A realistic torso phantom with average body size of Japanese adult males has been developed for the calibration of counting systems used for in-vivo measurements of plutonium and other actinides. The phantom contains removable model organs (lungs, liver, kidneys and heart), model trachea and artificial rib cage, and also includes chest plates that can be placed over the chest to simulate wide range adipose/muscle ratio in the human chest. Tissue substitutes used in the phantom were made of polyurethane with different concentrations of ester of phosphoric acid. Model lungs were made of foamed polyurethane with small quantities of the additive, and the artificial rib cage was made of epoxy resin with calcium carbonate. The experimental data have shown that the phantom can be used as a standard phantom for the calibration.

  7. Robotic Mirror Therapy System for Functional Recovery of Hemiplegic Arms.

    Science.gov (United States)

    Beom, Jaewon; Koh, Sukgyu; Nam, Hyung Seok; Kim, Wonshik; Kim, Yoonjae; Seo, Han Gil; Oh, Byung-Mo; Chung, Sun Gun; Kim, Sungwan

    2016-08-15

    Mirror therapy has been performed as effective occupational therapy in a clinical setting for functional recovery of a hemiplegic arm after stroke. It is conducted by eliciting an illusion through use of a mirror as if the hemiplegic arm is moving in real-time while moving the healthy arm. It can facilitate brain neuroplasticity through activation of the sensorimotor cortex. However, conventional mirror therapy has a critical limitation in that the hemiplegic arm is not actually moving. Thus, we developed a real-time 2-axis mirror robot system as a simple add-on module for conventional mirror therapy using a closed feedback mechanism, which enables real-time movement of the hemiplegic arm. We used 3 Attitude and Heading Reference System sensors, 2 brushless DC motors for elbow and wrist joints, and exoskeletal frames. In a feasibility study on 6 healthy subjects, robotic mirror therapy was safe and feasible. We further selected tasks useful for activities of daily living training through feedback from rehabilitation doctors. A chronic stroke patient showed improvement in the Fugl-Meyer assessment scale and elbow flexor spasticity after a 2-week application of the mirror robot system. Robotic mirror therapy may enhance proprioceptive input to the sensory cortex, which is considered to be important in neuroplasticity and functional recovery of hemiplegic arms. The mirror robot system presented herein can be easily developed and utilized effectively to advance occupational therapy.

  8. Terror, Failure, Resistance. Conflicting Memory of Armed Acts of Anti-Communist Resistance in Czechoslovakia

    Czech Academy of Sciences Publication Activity Database

    Devátá, Markéta

    -, č. 5 (2017), s. 63-100 ISSN 2336-3142 Institutional support: RVO:68378114 Keywords : resistance * Communist regime * armed acts Subject RIV: AB - History OBOR OECD: History (history of science and technology to be 6.3, history of specific sciences to be under the respective headings)

  9. Multicenter retrospective study of noncompressible torso hemorrhage: Anatomic locations of bleeding and comparison of endovascular versus open approach.

    Science.gov (United States)

    Chang, Ronald; Fox, Erin E; Greene, Thomas J; Eastridge, Brian J; Gilani, Ramyar; Chung, Kevin K; DeSantis, Stacia M; DuBose, Joseph J; Tomasek, Jeffrey S; Fortuna, Gerald R; Sams, Valerie G; Todd, S Rob; Podbielski, Jeanette M; Wade, Charles E; Holcomb, John B

    2017-07-01

    Rational development of technology for rapid control of noncompressible torso hemorrhage (NCTH) requires detailed understanding of what is bleeding. Our objectives were to describe the anatomic location of truncal bleeding in patients presenting with NCTH and compare endovascular (ENDO) management versus open (OPEN) management. This is a retrospective study of adult trauma patients with NCTH admitted to four urban Level I trauma centers in the Houston and San Antonio metropolitan areas in 2008 to 2012. Inclusion criteria include named axial torso vessel disruption, Abbreviated Injury Scale chest or abdomen score of 3 or higher with shock (base excess, bleeding locations were 25% chest, 41% abdomen, and 31% pelvis. ENDO was used to treat relatively few types of vascular injuries, whereas OPEN and RT injuries were more diverse. ENDO patients had more blunt trauma (95% vs. 34% vs. 32%); severe injuries (median Injury Severity Score, 34 vs. 27 vs. 21), and increased time to intervention (median, 298 vs. 92 vs. 51 minutes) compared with OPEN and RT. Mortality was 15% versus 20% versus 79%. ENDO was associated with decreased mortality compared to OPEN (relative risk, 0.58; 95% confidence interval, 0.46-0.73). Although ENDO may reduce mortality in NCTH patients, significant group differences limit the generalizability of this finding. Therapeutic, level V.

  10. Fabrication of a tissue-equivalent torso phantom for intercalibration of in-vivo transuranic-nuclide counting facilities

    International Nuclear Information System (INIS)

    Griffith, R.V.; Dean, P.N.; Anderson, A.L.; Fisher, J.C.

    1978-01-01

    A tissue-equivalent human-torso phantom has been constructed for calibration of the counting systems used for in-vivo measurement of transuranic nuclides. The phantom contains a human male rib cage, removable model organs, and includes tissue-equivalent chest plates that can be placed over the torso to simulate people with a wide range of statures. The organs included are lungs, heart, liver, kidneys, spleen, and tracheo-bronchial lymph nodes. Polyurethane with different concentrations of calcium carbonate was used to simulate the linear photon-attenuation properties of various human tissues--lean muscle, adipose-muscle mixtures, and cartilage. Foamed polyurethane with calcium carbonate simulates lung tissue. Transuranic isotopes can be incorporated uniformly in the phantom's lungs and other polyurethane-based organs by dissolution of the nitrate form in acetone with lanthanum nitrate carrier. Organs have now been labelled with highly pure 238 Pu, 239 Pu, and 241 Am for calibration measurements. This phantom is the first of three that will be used in a U.S. Department of Energy program of intercomparisons involving more than ten laboratories. The results of the intercomparison will allow participating laboratories to prepare sets of transmission curves that can be used to predict the performance of their counting systems for a wide range of subject builds and organ depositions. The intercomparison will also provide valuable information on the relative performance of a variety of detector systems and counting techniques

  11. Three-dimensional reconstruction of axonemal outer dynein arms in situ by electron tomography.

    Science.gov (United States)

    Lupetti, Pietro; Lanzavecchia, Salvatore; Mercati, David; Cantele, Francesca; Dallai, Romano; Mencarelli, Caterina

    2005-10-01

    We present here for the first time a 3D reconstruction of in situ axonemal outer dynein arms. This reconstruction has been obtained by electron tomography applied to a series of tilted images collected from metal replicas of rapidly frozen, cryofractured, and metal-replicated sperm axonemes of the cecidomid dipteran Monarthropalpus flavus. This peculiar axonemal model consists of several microtubular laminae that proved to be particularly suitable for this type of analysis. These laminae are sufficiently planar to allow the visualization of many dynein molecules within the same fracture face, allowing us to recover a significant number of equivalent objects and to improve the signal-to-noise ratio of the reconstruction by applying advanced averaging protocols. The 3D model we obtained showed the following interesting structural features: First, each dynein arm has two head domains that are almost parallel and are obliquely oriented with respect to the longitudinal axis of microtubules. The two heads are therefore positioned at different distances from the surface of the A-tubule. Second, each head domain consists of a series of globular subdomains that are positioned on the same plane. Third, a stalk domain originates as a conical region from the proximal head and ends with a small globular domain that contacts the B-tubule. Fourth, the stem region comprises several globular subdomains and presents two distinct points of anchorage to the surface of the A-tubule. Finally, and most importantly, contrary to what has been observed in isolated dynein molecules adsorbed to flat surfaces, the stalk and the stem domains are not in the same plane as the head.

  12. A new optimization approach for nozzle selection and component allocation in multi-head beam-type SMD placement machines

    NARCIS (Netherlands)

    Torabi, S.A.; Hamedi, M.; Ashayeri, J.

    2013-01-01

    This paper addresses a highly challenging scheduling problem faced in multi-head beam-type surface mounting devices (SMD) machines. An integrated mathematical model is formulated aiming to balance workloads over multiple heads as well as improving the traveling speed of the robotic arm by

  13. Automatic anatomy partitioning of the torso region on CT images by using multiple organ localizations with a group-wise calibration technique

    Science.gov (United States)

    Zhou, Xiangrong; Morita, Syoichi; Zhou, Xinxin; Chen, Huayue; Hara, Takeshi; Yokoyama, Ryujiro; Kanematsu, Masayuki; Hoshi, Hiroaki; Fujita, Hiroshi

    2015-03-01

    This paper describes an automatic approach for anatomy partitioning on three-dimensional (3D) computedtomography (CT) images that divide the human torso into several volume-of-interesting (VOI) images based on anatomical definition. The proposed approach combines several individual detections of organ-location with a groupwise organ-location calibration and correction to achieve an automatic and robust multiple-organ localization task. The essence of the proposed method is to jointly detect the 3D minimum bounding box for each type of organ shown on CT images based on intra-organ-image-textures and inter-organ-spatial-relationship in the anatomy. Machine-learning-based template matching and generalized Hough transform-based point-distribution estimation are used in the detection and calibration processes. We apply this approach to the automatic partitioning of a torso region on CT images, which are divided into 35 VOIs presenting major organ regions and tissues required by routine diagnosis in clinical medicine. A database containing 4,300 patient cases of high-resolution 3D torso CT images is used for training and performance evaluations. We confirmed that the proposed method was successful in target organ localization on more than 95% of CT cases. Only two organs (gallbladder and pancreas) showed a lower success rate: 71 and 78% respectively. In addition, we applied this approach to another database that included 287 patient cases of whole-body CT images scanned for positron emission tomography (PET) studies and used for additional performance evaluation. The experimental results showed that no significant difference between the anatomy partitioning results from those two databases except regarding the spleen. All experimental results showed that the proposed approach was efficient and useful in accomplishing localization tasks for major organs and tissues on CT images scanned using different protocols.

  14. The effectiveness of thyme honey for the management of treatment-induced xerostomia in head and neck cancer patients: A feasibility randomized control trial.

    Science.gov (United States)

    Charalambous, Andreas; Lambrinou, Ekaterini; Katodritis, Nicos; Vomvas, Dimitrios; Raftopoulos, Vasilios; Georgiou, Morpho; Paikousis, Lefkios; Charalambous, Melanie

    2017-04-01

    Radiation-induced xerostomia is one of the most common side effects that head and neck cancer patients experience during and after treatment. Despite the various methods for the prevention and treatment of radiation-induced xerostomia, it remains highly prevalent among patients treated for head and neck cancers negatively influencing their lives. The purpose of this study was to evaluate the effectiveness of thyme honey as a means for managing radiation-induced xerostomia. This was a parallel randomised controlled trial with two equal arms, the experimental arm (thyme honey) and the control arm (saline). 72 head and neck cancer patients receiving radiotherapy or/and chemotherapy or/and surgery were recruited in a specialised cancer centre. Patients in both arms followed the same administration protocol with thyme honey and saline respectively. Identical assessments at baseline, 1 month and 6 months following completion of the intervention were performed in both arms including the National Cancer Institute (NCI) xerostomia scale and the Xerostomia Questionnaire (XQ) additionally to weekly oral clinical assessments. The ClinicalTrials.gov Identifier for this study is NCT01465308. Linear Mixed Models revealed the statistically significant effect of the intervention on xerostomia (F = 8.474 p xerostomia. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. CT dose modulation using automatic exposure control in whole-body PET/CT: effects of scout imaging direction and arm positioning.

    Science.gov (United States)

    Inoue, Yusuke; Nagahara, Kazunori; Kudo, Hiroko; Itoh, Hiroyasu

    2018-01-01

    Automatic exposure control (AEC) modulates tube current and consequently X-ray exposure in CT. We investigated the behavior of AEC systems in whole-body PET/CT. CT images of a whole-body phantom were acquired using AEC on two scanners from different manufactures. The effects of scout imaging direction and arm positioning on dose modulation were evaluated. Image noise was assessed in the chest and upper abdomen. On one scanner, AEC using two scout images in the posteroanterior (PA) and lateral (Lat) directions provided relatively constant image noise along the z-axis with the arms at the sides. Raising the arms increased tube current in the head and neck and decreased it in the body trunk. Image noise increased in the upper abdomen, suggesting excessive reduction in radiation exposure. AEC using the PA scout alone strikingly increased tube current and reduced image noise in the shoulder. Raising the arms did not substantially influence dose modulation and decreased noise in the abdomen. On the other scanner, AEC using the PA scout alone or Lat scout alone resulted in similar dose modulation. Raising the arms increased tube current in the head and neck and decreased it in the trunk. Image noise was higher in the upper abdomen than in the middle and lower chest, and was not influenced by arm positioning. CT dose modulation using AEC may vary greatly depending on scout direction. Raising the arms tended to decrease radiation exposure; however, the effect depends on scout direction and the AEC system.

  16. Sequential vs alternate chemo-radiotherapy in advanced head and neck tumors

    International Nuclear Information System (INIS)

    Corvo', R.; Merlano, M.; Grimaldi, A.; Rosso, R.; Vitale, V.; Scarpati, D.; Santelli, A.; Scasso, F.

    1988-01-01

    Between 1983 and 1986, a multicenter randomized study was conducted to compare a sequential program of induction chemotherapy (CT) followed by radiotherapy (RT), Arm A, with an alteration of cycles of CT with 3 courses of RT (20 Gy/10 fractions up to a total dose of 60 Gy), Arm B, in advanced head and neck cancer patients. The same CT (VBM: Vinblastine, Bleomycin, Methotrexate) was used on both arms; one hundred and sixteen patients (pts) entered the study, 55 in Arm A, 61 in Arm B. Fourty-five pts had stage III and 71 stage IV cancers. The two arms are fully comparable. Up to October 1987, 116 pts are evaluable for survival, while 112 are evaluable for toxicity and 105 for response. In 21 patients (10 in Arm A, 11 in B) the association CT-RT was followed by surgery. Response analysis shows 14 complete responses in Arm A and 30 in Arm B (p≤0.03). The madian disease-free survival and median overall survival are also statistically different, with an advantage for Arm B (33 vs 22 weeks, p≤0.0007, and 59 vs 38 weeks, p<0.03 respectively). The actual overall survival of complete responders at 50 months id 43% (B) and 21% (A). Toxicity (mainly stage III-IV mucositis) is superior in Arm B (30% vs 4%). This experience demonstrates the advantages of alternate over sequential CT-RT. A comparison of this cyclic assiciation with RT alone is in progress

  17. 3 Tesla MRI of patients with a vagus nerve stimulator: initial experience using a T/R head coil under controlled conditions.

    Science.gov (United States)

    Gorny, Krzysztof R; Bernstein, Matt A; Watson, Robert E

    2010-02-01

    To assess safety of clinical MRI of the head in patients with implanted model 100, 102, and 103 vagus nerve stimulation (VNS) Therapy Systems (Cyberonics, Inc., Houston, TX) in 3.0 Tesla MRI (GE Healthcare, Milwaukee, WI). The distributions of the radiofrequency B(1) (+)-field produced by the clinically used transmit/receive (T/R) head coil (Advanced Imaging Research Incorporated, Cleveland, OH) and body coil were measured in a head and shoulders phantom. These measurements were supplemented by temperature measurements on the lead tips and the implantable pulse generator (IPG) of the VNS devices in a head and torso phantom with the same two coils. Clinical 3T MRI head scans were then acquired under highly controlled conditions in a series of 17 patients implanted with VNS. Phantom studies showed only weak B(1) (+) fields at the location of the VNS IPG and leads for MRI scans using the T/R head coil. The MRI-related heating on a VNS scanned in vitro at 3T was also found to be minimal (0.4-0.8 degrees C at the leads, negligible at the IPG). The patient MRI examinations were completed successfully without any adverse incidents. No patient reported any heating, discomfort, or any other unusual sensation. Safe clinical MRI head scanning of patients with implanted VNS is shown to be feasible on a GE Signa Excite 3T MRI system using one specific T/R head coil. These results apply to this particular MRI system configuration. Extrapolation or generalization of these results to more general or less controlled imaging situations without supporting data of safety is highly discouraged.

  18. Effects of balance ability and handgrip height on kinematics of the gait, torso, and pelvis in elderly women using a four-wheeled walker.

    Science.gov (United States)

    Choi, Hyuk-Jae; Ko, Chang-Yong; Kang, Sungjae; Ryu, Jeicheong; Mun, Museong; Jeon, Hye-Seon

    2015-02-01

    Numerous elderly individuals use the four-wheeled walker (FWW) as a gait-assistive device. The walker's handgrip height is important for correct use. However, few clinical studies have investigated the biomechanical effects of the FWW's handgrip height on balance. Therefore, the present study assessed kinematic features of the gait, torso and pelvis during use of the FWW at two levels of handgrip height (48% vs 55% of the subject's height) while assessing balance in older adults. A total of 20 older adults were allocated into two groups according to the Berg Balance Scale (BBS): good balance (GB; BBS≥46) versus poor balance (PB; BBS<45). Participants walked with the FWW at 48% or 55% handgrip height for 10 m. Our study showed that the double-support period and stance phase significantly increased at 55% handgrip height, but the swing phase significantly decreased in the GB group. In the PB group, velocity and stride length significantly increased at 55% handgrip height. Tilt angle of the torso in the GB group was significantly lower at 55% than at 48% handgrip height, but no differences were observed in the PB group. In the pelvis, initial contact and toe-off angles of tilt were lower in the GB group at 55% handgrip height, but no differences were observed in the PB group. These results showed that kinematic features of the gait, torso, and pelvis in older adults using the FWW might be dependent on the handgrip height of the FWW and the patient's balance. Additionally, greater than 48% of the body height might be appropriate for older adults with poor balance. © 2014 Japan Geriatrics Society.

  19. Precise Head Tracking in Hearing Applications

    Science.gov (United States)

    Helle, A. M.; Pilinski, J.; Luhmann, T.

    2015-05-01

    The paper gives an overview about two research projects, both dealing with optical head tracking in hearing applications. As part of the project "Development of a real-time low-cost tracking system for medical and audiological problems (ELCoT)" a cost-effective single camera 3D tracking system has been developed which enables the detection of arm and head movements of human patients. Amongst others, the measuring system is designed for a new hearing test (based on the "Mainzer Kindertisch"), which analyzes the directional hearing capabilities of children in cooperation with the research project ERKI (Evaluation of acoustic sound source localization for children). As part of the research project framework "Hearing in everyday life (HALLO)" a stereo tracking system is being used for analyzing the head movement of human patients during complex acoustic events. Together with the consideration of biosignals like skin conductance the speech comprehension and listening effort of persons with reduced hearing ability, especially in situations with background noise, is evaluated. For both projects the system design, accuracy aspects and results of practical tests are discussed.

  20. 49 CFR 572.15 - General description.

    Science.gov (United States)

    2010-10-01

    ... Transportation Other Regulations Relating to Transportation (Continued) NATIONAL HIGHWAY TRAFFIC SAFETY... Assembly SA 103C 030 Torso Assembly SA 103C 041 Upper Arm Assembly Left SA 103C 042 Upper Arm Assembly Right SA 103C 051 Forearm Hand Assembly Left SA 103C 052 Forearm Hand Assembly Right SA 103C 061Upper...

  1. Assessment of margins in resection specimens for head and neck malignancies.

    Science.gov (United States)

    Janjua, Omer Sefvan; Ahmed, Waseem; Qureshi, Sana Mehmood; Khan, Tariq Sarfaraz; Ahmed, Ashfaq; Alamgir, Wajiha

    2013-04-01

    To determine the relative frequency of clear, close and involved margins in resection specimens for head and neck malignancies. An observational study. The Department of Oral and Maxillofacial Surgery, Armed Forces Institute of Dentistry, Rawalpindi and the Department of Histopathology, Armed Forces Institute of Pathology, Rawalpindi, from January 2008 to December 2010. Tumour registers and computer data bases in the department of Histopathology of Armed Forces Institute of Pathology, Rawalpindi, were analyzed for the cases of malignancies involving head and neck region that were sent for histopathological analysis after resection in the last three years. Histopathology reports were obtained. The data regarding age, gender, site, type of malignancy and margin status (clear, close or involved) was recorded on specially designed proformas for the study and later on analyzed by using SPSS version 17.0. Results were expressed. A total of 319 cases were registered in the study duration. The age of the patients ranged from 22-90 years (mean 59.5 + 14.1 years). Male to female ratio was 1.53:1. One hundred and thirty six (42.6%) were squamous cell carcinoma (SCC), 163 were basal cell carcinomas (BCC, 51.0%); the rest included 18 salivary gland malignancies (5.7%) and one carcino-sarcoma (0.31%) and chondrosarcoma each. All margins were found clear in 137 patients (42.9%); involved in 168 cases (52.7%) and close in 14 cases (4.4%). Margin clearance could not be achieved in more than 50% cases, this can lead to poor prognosis. Hence, methods should be adopted to improve the margin clearance in various head and neck malignancies.

  2. Assessment of margins in resection specimens for head and neck malignancies

    International Nuclear Information System (INIS)

    Janjua, O. S.; Ahmed, W.; Ahmed, A.; Qureshi, S. M.; Khan, T. S.; Alamgir, W.

    2013-01-01

    Objective: To determine the relative frequency of clear, close and involved margins in resection specimens for head and neck malignancies. Study Design: An observational study. Place and Duration of Study: The Department of Oral and Maxillofacial Surgery, Armed Forces Institute of Dentistry, Rawalpindi and the Department of Histopathology, Armed Forces Institute of Pathology, Rawalpindi, from January 2008 to December 2010. Methodology: Tumour registers and computer data bases in the department of Histopathology of Armed Forces Institute of Pathology, Rawalpindi, were analyzed for the cases of malignancies involving head and neck region that were sent for histopathological analysis after resection in the last three years. Histopathology reports were obtained. The data regarding age, gender, site, type of malignancy and margin status (clear, close or involved) was recorded on specially designed proformas for the study and later on analyzed by using SPSS version 17.0. Results were expressed. Results: A total of 319 cases were registered in the study duration. The age of the patients ranged from 22 - 90 years (mean 59.5 + 14.1 years). Male to female ratio was 1.53:1. One hundred and thirty six (42.6%) were squamous cell carcinoma (SCC), 163 were basal cell carcinomas (BCC, 51.0%); the rest included 18 salivary gland malignancies (5.7%) and one carcino-sarcoma (0.31%) and chondrosarcoma each. All margins were found clear in 137 patients (42.9%); involved in 168 cases (52.7%) and close in 14 cases (4.4%). Conclusion: Margin clearance could not be achieved in more than 50% cases, this can lead to poor prognosis. Hence, methods should be adopted to improve the margin clearance in various head and neck malignancies. (author)

  3. Randomized phase III trial of concurrent chemoradiotherapy vs accelerated hyperfractionation radiotherapy in locally advanced head and neck cancer

    International Nuclear Information System (INIS)

    Chitapanarux, Imjai; Kamnerdsupaphon, Pimkhuan; Pukanhapan, Nantaka; Tharavichitkul, Ekkasit; Vongtama, Roy

    2013-01-01

    The aim of this study was to compare the efficacy and safety of concurrent chemoradiotherapy (CCRT) vs accelerated hyperfractionation with concomitant boost (CCB) as a primary treatment for patients with Stage III-IV squamous cell carcinoma of head and neck (SCCHN). A total of 85 non-metastatic advanced SCCHN patients were accrued from January 2003 to December 2007. Of these, 48 and 37 patients received CCRT and CCB, respectively. The patients were randomized to receive either three cycles of carboplatin and 5-fluorouracil plus conventional radiotherapy (CCRT, 66 Gy in 6.5 weeks) or hybrid accelerated radiotherapy (CCB, 70 Gy in 6 weeks). The primary endpoint was determined by locoregional control rate. The secondary endpoints were overall survival and toxicity. With a median follow-up of 43 months (range, 3-102), the 5-year locoregional control rate was 69.6% in the CCRT arm vs 55.0% in the CCB arm (P = 0.184). The 5-year overall survival rate was marginally significantly different (P = 0.05): 76.1% in the CCRT arm vs 63.5% in the CCB arm. Radiotherapy treatment interruptions of more than three days were 60.4% and 40.5% in the CCRT arm and CCB arm, respectively. The median total treatment time was 55.5 days in the CCRT arm and 49 days in the CCB arm. The rate of Grade 3 - 4 acute mucositis was significantly higher in the CCB arm (67.6% vs 41.7%, P = 0.01), but no high grade hematologic toxicities were found in the CCB arm (27.2% vs 0%). CCRT has shown a trend of improving outcome over CCB irradiation in locoregionally advanced head and neck cancer. (author)

  4. Proprioceptive Interaction between the Two Arms in a Single-Arm Pointing Task.

    Directory of Open Access Journals (Sweden)

    Kazuyoshi Kigawa

    Full Text Available Proprioceptive signals coming from both arms are used to determine the perceived position of one arm in a two-arm matching task. Here, we examined whether the perceived position of one arm is affected by proprioceptive signals from the other arm in a one-arm pointing task in which participants specified the perceived position of an unseen reference arm with an indicator paddle. Both arms were hidden from the participant's view throughout the study. In Experiment 1, with both arms placed in front of the body, the participants received 70-80 Hz vibration to the elbow flexors of the reference arm (= right arm to induce the illusion of elbow extension. This extension illusion was compared with that when the left arm elbow flexors were vibrated or not. The degree of the vibration-induced extension illusion of the right arm was reduced in the presence of left arm vibration. In Experiment 2, we found that this kinesthetic interaction between the two arms did not occur when the left arm was vibrated in an abducted position. In Experiment 3, the vibration-induced extension illusion of one arm was fully developed when this arm was placed at an abducted position, indicating that the brain receives increased proprioceptive input from a vibrated arm even if the arm was abducted. Our results suggest that proprioceptive interaction between the two arms occurs in a one-arm pointing task when the two arms are aligned with one another. The position sense of one arm measured using a pointer appears to include the influences of incoming information from the other arm when both arms were placed in front of the body and parallel to one another.

  5. Clinical and Radiographic Outcomes of Unipolar and Bipolar Radial Head Prosthesis in Patients with Radial Head Fracture: A Systemic Review and Meta-Analysis.

    Science.gov (United States)

    Chen, Hongwei; Wang, Ziyang; Shang, Yongjun

    2018-06-01

    To compare clinical outcomes of unipolar and bipolar radial head prosthesis in the treatment of patients with radial head fracture. Medline, Cochrane, EMBASE, Google Scholar databases were searched until April 18, 2016 using the following search terms: radial head fracture, elbow fracture, radial head arthroplasty, implants, prosthesis, unipolar, bipolar, cemented, and press-fit. Randomized controlled trials, retrospective, and cohort studies were included. The Mayo elbow performance score (MEPS), disabilities of the arm, shoulder, and hand (DASH) score, radiologic assessment, ROM, and grip strength following elbow replacement were similar between prosthetic devices. The pooled mean excellent/good ranking of MEPS was 0.78 for unipolar and 0.73 for bipolar radial head arthroplasty, and the pooled mean MEPS was 86.9 and 79.9, respectively. DASH scores for unipolar and bipolar prosthesis were 19.0 and 16.3, respectively. Range of motion outcomes were similar between groups, with both groups have comparable risk of flexion arc, flexion, extension deficit, rotation arc, pronation, and supination (p values bipolar prosthesis). However, bipolar radial head prosthesis was associated with an increased chance of heterotopic ossification and lucency (p values ≤0.049) while unipolar prosthesis was not (p values ≥0.088). Both groups had risk for development of capitellar osteopenia or erosion/wear (p values ≤0.039). Unipolar and bipolar radial head prostheses were similar with respect to clinical outcomes. Additional comparative studies are necessary to further compare different radial head prostheses used to treat radial head fracture.

  6. Effects of arm truncation on the appearance of the halo artifact in {sup 68}Ga-PSMA-11 (HBED-CC) PET/MRI

    Energy Technology Data Exchange (ETDEWEB)

    Afshar-Oromieh, Ali; Haberkorn, Uwe [Heidelberg University Hospital, Department of Nuclear Medicine, Heidelberg (Germany); German Cancer Research Center, Clinical Cooperation Unit Nuclear Medicine, Heidelberg (Germany); Wolf, Maya; Gnirs, Regula; Schlemmer, Heinz-Peter; Freitag, Martin T. [German Cancer Research Center, Department of Radiology, Heidelberg (Germany); Kachelriess, Marc [German Cancer Research Center, Department of Medical Physics in Radiology, Heidelberg (Germany); Kopka, Klaus [German Cancer Research Center, Division of Radiopharmaceutical Chemistry, Heidelberg (Germany)

    2017-09-15

    PSMA ligand imaging with hybrid PET/MRI scanners could be an integral part of the clinical routine in the future. However, the first study about this novel method revealed a severe photopenic artifact (''halo artifact'') around the urinary bladder causing significantly reduced tumor visibility. The aim of this evaluation was to analyze the role of arm truncation on the appearance of the halo artifact in {sup 68}Ga-PSMA-11 PET/MRI hypothesizing that this influences the appearance. Twenty-seven consecutive patients were subjected to {sup 68}Ga-PSMA-11 PET/CT (1 h p.i.) followed by PET/MRI (3 h p.i.). PET/MRI was first started with scans of the abdomen to pelvis with arms positioned up above the head. Immediately thereafter, additional scans from the pelvis to abdomen were conducted with arms positioned down beside the trunk. All investigations were first analyzed separately and then compared with respect to tumor detection and tumor uptake (SUV) as well as the presence and intensity of the halo artifact. The Wilcoxon signed rank test was used to determine statistical differences including Bonferroni correction. The halo was significantly reduced if the arms were elevated. Lesions inside the halo artifact (n = 16) demonstrated significantly increased SUVmean (p = 0.0007) and SUVmax (p = 0.0024) with arms positioned up. The halo appearance and intensity was not dependent on the total activity and activity concentration of the urinary bladder. Positioning the arms down was shown to be significantly associated with the appearance of the halo artifact in PET/MRI. Positioning the arms up above the head can significantly reduce the halo artifact, thereby detecting more tumor lesions. (orig.)

  7. Variation of gunshot injury patterns in mortality associated with human rights abuses and armed conflict: an exploratory study.

    Science.gov (United States)

    Baraybar, Jose Pablo

    2015-09-01

    The analysis of the distribution of gunshot injuries in a sample of 777 sets of human remains of proven human rights abuse from Somaliland, the Balkans and Peru is compared to frequencies of injuries sustained by combatants in contemporary conflicts reported in the literature. Principal Component Analysis (PCA) reduced the data to three components accounting for 82.94% of the variance. The first component with 38.31% of variance shows segments Arms and thorax/abdomen to be positively correlated (0.887 and 0.662, respectively); the segment head/neck is strongly correlated (0.951) to the second component while the segment thorax/abdomen shows a low, negative correlation (-0.388). Finally in the third component only the legs are strongly correlated (0.991). Data was further subjected to a K-means cluster analysis to determine the likely groupings combining the four types of injuries. Each of the three clusters reproduced similar patterns observed in the PCA: Cluster 1 shows the prevalence of injuries to the thorax/abdomen and extremities in addition to injuries to the head/neck; Cluster 2 shows injuries to the head/neck and Cluster 3 injuries to the thorax/abdomen and a lower representation of the arms and legs. Most of the cases (70.5%), irrespective of geography and type of site (attack or detention), were grouped into Cluster 2. Such comparison shows that in human rights abuse, irrespective of their geography, gunshot injuries tend to follow a pattern favouring the head/neck and thorax/abdomen areas over the extremities, the reverse pattern observed in contemporary combat operations. In those settings gunshot wound trauma is the second cause of mortality/morbidity (after fragmenting ammunition) and its distribution concentrates on the extremities, thorax/abdomen and head; following the pattern of protective armour when it is used. Considering that human rights abuses are often presented as encounters between two armed groups in the context of counter

  8. The profound effects of patient arm positioning on organ doses from CT procedures calculated using Monte Carlo simulations and deformable phantoms

    International Nuclear Information System (INIS)

    Liu, Haikuan; Gao, Yiming; Ding, Aiping; Caracappa, Peter F.; George Xu, X.

    2015-01-01

    current necessary to overcome the presence of the arms while maintaining sufficient image quality Arm position affects the dose to internal organs from CT scans by as much as 25.3 %. The presence of arms in the scan range results in a dose increase for the skin and bone surface, but a dose decrease for organs located in the torso. Considering the use of TCM, which is common in many clinics, the patient having lowered arms may receive 50 % higher radiation dose to most of the organs because of the increased tube current. The use of higher tube voltage might narrow such dose differences between patients of these two postures due to the greater penetration of higher-energy X rays. Therefore, when calculating or reporting patient doses from CT scans, it is prudent to select an appropriate phantom that accurately represents the patient posture. (authors)

  9. Virtual sine arm kinematic mount system

    International Nuclear Information System (INIS)

    Xu, Z.; Randall, K.J.

    1997-01-01

    A novel kinematic mount system for a vertical focusing mirror of the soft x-ray spectroscopy beamline at the Advanced Photon Source is described. The system contains three points in a horizontal plane. Each point consists of two horizontal linear precision stages, a spherical ball bearing, and a vertical precision stage. The horizontal linear stages are aligned orthogonally and are conjoined by a spherical ball bearing, supported by the vertical linear stage at each point. The position of each confined horizontal stage is controlled by a motorized micrometer head by spring-loading the flat tip of the micrometer head onto a tooling ball fixing on the carriage of the stage. A virtual sine arm is formed by tilting the upstream horizontal stage down and the two downstream horizontal stages up by a small angle. The fine pitch motion is achieved by adjusting the upstream stage. This supporting structure is extremely steady due to a relatively large span across the supporting points and yields extremely high resolution on the pitch motion. With a one degree tilt and a microstepping motor, the authors achieved a 0.4 nanoradian resolution on the mirror pitch motion

  10. Aircraft Crash Survival Design Guide. Volume 2. Aircraft Crash Environment and Human Tolerance

    Science.gov (United States)

    1980-01-01

    a whipping action’of the head, and often, impact of the upper torso on the legs, resulting in chest, head, and neck injuries . Head injuries due to...K., at al., COMPARATIVE TOLERANCE FOR CEREBRAL CONCUSSION BY HEAD IMPACT AND WHIPLASH INJURY IN PRIMATES , 1970 International Automobile Safety...FROM HEAD IMPACT AND WHIPLASH IN PRIMATES , Journal of Biomechanics, Vol. 4, 1971, pp. 13-21. 18. Goldsmith, W., BIOMECHANICS OF HEAD INJURY , In

  11. Rare muscular variations identified in a single cadaveric upper limb: a four-headed biceps brachii and muscular elevator of the latissimus dorsi tendon.

    Science.gov (United States)

    Moore, Colin W; Rice, Charles L

    2018-03-01

    Supernumerary or accessory heads of the biceps brachii are persistent muscular structures which can vary in number and location in the arm. Variations in other arm muscles, such as the coracobrachialis, can accompany supernumerary biceps brachii musculature in the upper limb. In this case report, we describe two rare muscular variants in a single adult male: a four-headed biceps brachii and the muscular elevator of the latissimus dorsi tendon. Additionally, accessory muscles of the brachialis and flexor digiti minimi brevis were identified in the upper limb. To our knowledge, the muscular variants identified here are considered rare, and their co-occurrence in a single upper limb has not been described previously. Also, a four-headed biceps brachii consisting of both the infero-medial and infero-lateral humeral heads has not been described previously to our knowledge. We postulate that the simultaneous appearance of several muscular variations may indicate a signaling disruption in embryogenesis during muscle patterning of the ventral limb bud. Knowledge of variant musculature in the arm is important for surgeons and clinicians as these muscles and their aberrant innervation patterns can complicate surgical procedures and may compress arteries and nerves producing upper limb pain and paresthesia. The clinical, functional and embryological implications of the upper limb variants are discussed.

  12. Absence of musculocutaneous nerve and accessory head of biceps brachii: a case report

    Directory of Open Access Journals (Sweden)

    Arora L

    2005-01-01

    Full Text Available During dissection of a 55-year-old female cadaver, we observed that three nerve roots contributed to the formation of Median nerve in her right upper limb. Along with this variation, absence of Musculocutaneous nerve was noticed. The muscles of front of arm i.e. Biceps Brachii, Brachialis and Coracobrachialis received their nerve supply from Median nerve. The Lateral cutaneous nerve of forearm was derived from Median nerve. Also an accessory head of Biceps Brachii muscle was present in the right arm of the same cadaver. It is extremely important to be aware of these variations while planning a surgery in the region of axilla or arm as these nerves are more liable to be injured during operations.

  13. Detection of skeletal muscle metastasis: torso FDG PET-CT versus contrast-enhanced chest or abdomen CT.

    Science.gov (United States)

    So, Young; Yi, Jeong Geun; Song, Inyoung; Lee, Won Woo; Chung, Hyun Woo; Park, Jeong Hee; Moon, Sung Gyu

    2015-07-01

    Skeletal muscle metastasis (SMM) in cancer patients has not been sufficiently evaluated regarding prevalence and proper method of detection. To determine the prevalence of SMM and compare the diagnostic competencies for SMM of torso F-18 fluorodeoxyglucose (FDG) positron emission tomography-computed tomography (PET-CT) and contrast-enhanced chest or abdomen CT. We investigated 18,225 PET-CT studies of 6359 cancer patients performed from 2005 to 2012. The PET-CT studies describing potential SMM were retrieved and the corresponding medical records were reviewed. The gold standard for SMM was histopathologically-proven SMM or imaging study-based disease progression. The detectability of SMM was compared between PET-CT and contrast-enhanced CT. Twenty-six patients had 84 SMM lesions, representing a SMM prevalence of 0.41%. Lung cancer was the most common SMM-associated malignancy (54%) and the gluteal/pelvic girdle muscle was the most frequently involved SMM site (37%). All 84 SMM lesions were visualized on PET-CT (100%). Of these PET-CT positive 84 SMM lesions, 51 lesions were in the CT field of view (FOV) (61%), whereas 33 lesions were out of the CT FOV (39%). Among these 51 lesions, 17 lesions showed rim-enhancing nodules/masses (33%), eight lesions showed homogeneously enhancing nodules (16%), three lesions showed heterogeneously enhancing nodules (6%), and 23 SMM lesions (45%) were non-diagnostic by CT. All 51 SMM lesions within CT FOV were detected on PET-CT (100%), whereas only 28 were visualized on CT (54.9%), resulting in a significant difference (P SMM was revealed by PET-CT. The prevalence of SMM was as low as 0.41% in the current large cohort of cancer patients. Torso PET-CT was a more competent modality than contrast-enhanced CT in the detection of SMM. © The Foundation Acta Radiologica 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  14. Lister vaccine strain of vaccinia virus armed with the endostatin-angiostatin fusion gene: an oncolytic virus superior to dl1520 (ONYX-015) for human head and neck cancer.

    Science.gov (United States)

    Tysome, James R; Wang, Pengju; Alusi, Ghassan; Briat, Arnaud; Gangeswaran, Rathi; Wang, Jiwei; Bhakta, Vipul; Fodor, Istvan; Lemoine, Nick R; Wang, Yaohe

    2011-09-01

    Oncolytic viral therapy represents a promising strategy for the treatment of head and neck squamous cell carcinoma (HNSCC), with dl1520 (ONYX-015) the most widely used oncolytic adenovirus in clinical trials. This study aimed to determine the effectiveness of the Lister vaccine strain of vaccinia virus as well as a vaccinia virus armed with the endostatin-angiostatin fusion gene (VVhEA) as a novel therapy for HNSCC and to compare them with dl1520. The potency and replication of the Lister strain and VVhEA and the expression and function of the fusion protein were determined in human HNSCC cells in vitro and in vivo. Finally, the efficacy of VVhEA was compared with dl1520 in vivo in a human HNSCC model. The Lister vaccine strain of vaccinia virus was more effective than the adenovirus against all HNSCC cell lines tested in vitro. Although the potency of VVhEA was attenuated in vitro, the expression and function of the endostatin-angiostatin fusion protein was confirmed in HNSCC models both in vitro and in vivo. This novel vaccinia virus (VVhEA) demonstrated superior antitumor potency in vivo compared with both dl1520 and the control vaccinia virus. This study suggests that the Lister strain vaccinia virus armed with an endostatin-angiostatin fusion gene may be a potential therapeutic agent for HNSCC.

  15. Ergonomic analysis of microlaryngoscopy

    Science.gov (United States)

    Statham, Melissa McCarty; Sukits, Alison L.; Redfern, Mark S.; Smith, Libby J.; Sok, John C.; Rosen, Clark A.

    2016-01-01

    Objectives/Hypothesis To apply ergonomic principles in analysis of three different operative positions used in laryngeal microsurgery. Study Design Prospective case-control study. Methods Laryngologists were studied in three different microlaryngeal operative positions: a supported position in a chair with articulated arm supports, a supported position with arms resting on a Mayo stand, and a position with arms unsupported. Operative positions were uniformly photographed in three dimensions. Full body postural data was collected and analyzed using the validated Rapid Upper Limb Assessment (RULA) tool to calculate a risk score indicative of potential musculoskeletal misuse in each position. Joint forces were calculated for the neck and shoulder, and compression forces were calculated for the L5/S1 disc space. Results Higher-risk postures were obtained with unfavorably adjusted eyepieces and lack of any arm support during microlaryngeal surgery. Support with a Mayo stand led to more neck flexion and strain. Using a chair with articulated arm supports leads to decreased neck strain, less shoulder torque, and decreased compressive forces on the L5/S1 disc space. Ideal postures during microlaryngoscopy place the surgeon with arms and feet supported, with shoulders in an unraised, neutral anatomic position, upper arms neutrally positioned 20° to 45° from torso, lower arms neutrally positioned 60° to 100° from torso, and wrists extended or flexed postures and repetitive stress injury may lead to reduced occupationally related musculoskeletal pain and may improve microsurgical motor control. Laryngoscope, 2010 PMID:19950376

  16. Utility of intraoperative diagnostic C-arm angiography for management of high grade subarachnoid hemorrhage

    Directory of Open Access Journals (Sweden)

    Zhikui Wei

    2015-06-01

    Full Text Available The accurate and efficient localization of underlying vascular lesions is crucial for prompt and definitive treatment of subarachnoid hemorrhage (SAH. To demonstrate the utility and feasibility of intraoperative C-arm angiography in cerebrovascular emergencies, we report five cases of high grade SAH and/or intracerebral hemorrhage (ICH where intraoperative diagnostic C-arm angiography was safely and effectively utilized. Initial evaluations of all patients included a non-contrast head CT scan, which was followed by urgent decompressive hemicraniectomy as a life-saving measure in the presence of markedly elevated intracranial pressure. Further diagnostic evaluations were performed intraoperatively using a multi-purpose C-arm angiography system. The C-arm angiography findings greatly aided the intraoperative planning and led to definitive treatments in four cases of SAH by elucidating the underlying neurovascular lesions. With this treatment strategy, two of the patients made moderately good recoveries from their SAH and/or ICH with a Glasgow outcome score (GOS of 4. Three of the patients expired despite maximal therapy mostly due to unfavorable presenting grade. These results suggest that C-arm angiography is a reasonable diagnostic and surgical planning tool for selected patients with high grade diffuse SAH who require immediate decompression.

  17. A Monte Carlo Simulation of the in vivo measurement of lung activity in the Lawrence Livermore National Laboratory torso phantom.

    Science.gov (United States)

    Acha, Robert; Brey, Richard; Capello, Kevin

    2013-02-01

    A torso phantom was developed by the Lawrence Livermore National Laboratory (LLNL) that serves as a standard for intercomparison and intercalibration of detector systems used to measure low-energy photons from radionuclides, such as americium deposited in the lungs. DICOM images of the second-generation Human Monitoring Laboratory-Lawrence Livermore National Laboratory (HML-LLNL) torso phantom were segmented and converted into three-dimensional (3D) voxel phantoms to simulate the response of high purity germanium (HPGe) detector systems, as found in the HML new lung counter using a Monte Carlo technique. The photon energies of interest in this study were 17.5, 26.4, 45.4, 59.5, 122, 244, and 344 keV. The detection efficiencies at these photon energies were predicted for different chest wall thicknesses (1.49 to 6.35 cm) and compared to measured values obtained with lungs containing (241)Am (34.8 kBq) and (152)Eu (10.4 kBq). It was observed that no statistically significant differences exist at the 95% confidence level between the mean values of simulated and measured detection efficiencies. Comparisons between the simulated and measured detection efficiencies reveal a variation of 20% at 17.5 keV and 1% at 59.5 keV. It was found that small changes in the formulation of the tissue substitute material caused no significant change in the outcome of Monte Carlo simulations.

  18. The spiral arms of the Milky Way: The relative location of each different arm tracer within a typical spiral arm width

    Energy Technology Data Exchange (ETDEWEB)

    Vallée, Jacques P., E-mail: jacques.vallee@nrc-cnrc.gc.ca [National Research Council Canada, National Science Infrastructure portfolio, Herzberg Astronomy and Astrophysics, 5071 West Saanich Road, Victoria, B.C., V9E 2E7 (Canada)

    2014-07-01

    From the Sun's location in the Galactic disk, different arm tracers (CO, H I, hot dust, etc.) have been employed to locate a tangent to each spiral arm. Using all various and different observed spiral arm tracers (as published elsewhere), we embark on a new goal, namely the statistical analysis of these published data (data mining) to statistically compute the mean location of each spiral arm tracer. We show for a typical arm cross-cut, a separation of 400 pc between the mid-arm and the dust lane (at the inner edge of the arm, toward the Galactic center). Are some arms major and others minor? Separating arms into two sets, as suggested by some, we find the same arm widths between the two sets. Our interpretation is that we live in a multiple (four-arm) spiral (logarithmic) pattern (around a pitch angle of 12°) for the stars and gas in the Milky Way, with a sizable interarm separation (around 3 kpc) at the Sun's location and the same arm width for each arm (near 400 pc from mid-arm to dust lane).

  19. The spiral arms of the Milky Way: The relative location of each different arm tracer within a typical spiral arm width

    International Nuclear Information System (INIS)

    Vallée, Jacques P.

    2014-01-01

    From the Sun's location in the Galactic disk, different arm tracers (CO, H I, hot dust, etc.) have been employed to locate a tangent to each spiral arm. Using all various and different observed spiral arm tracers (as published elsewhere), we embark on a new goal, namely the statistical analysis of these published data (data mining) to statistically compute the mean location of each spiral arm tracer. We show for a typical arm cross-cut, a separation of 400 pc between the mid-arm and the dust lane (at the inner edge of the arm, toward the Galactic center). Are some arms major and others minor? Separating arms into two sets, as suggested by some, we find the same arm widths between the two sets. Our interpretation is that we live in a multiple (four-arm) spiral (logarithmic) pattern (around a pitch angle of 12°) for the stars and gas in the Milky Way, with a sizable interarm separation (around 3 kpc) at the Sun's location and the same arm width for each arm (near 400 pc from mid-arm to dust lane).

  20. ARMin III – Arm Therapy Exoskeleton with an Ergonomic Shoulder Actuation

    Directory of Open Access Journals (Sweden)

    Tobias Nef

    2009-01-01

    Full Text Available Rehabilitation robots have become important tools in stroke rehabilitation. Compared to manual arm training, robot-supported training can be more intensive, of longer duration and more repetitive. Therefore, robots have the potential to improve the rehabilitation process in stroke patients. Whereas a majority of previous work in upper limb rehabilitation robotics has focused on end-effector-based robots, a shift towards exoskeleton robots is taking place because they offer a better guidance of the human arm, especially for movements with a large range of motion. However, the implementation of an exoskeleton device introduces the challenge of reproducing the motion of the human shoulder, which is one of the most complex joints of the body. Thus, this paper starts with describing a simplified model of the human shoulder. On the basis of that model, a new ergonomic shoulder actuation principle that provides motion of the humerus head is proposed, and its implementation in the ARMin III arm therapy robot is described. The focus lies on the mechanics and actuation principle. The ARMin III robot provides three actuated degrees of freedom for the shoulder and one for the elbow joint. An additional module provides actuated lower arm pro/supination and wrist flexion/extension. Five ARMin III devices have been manufactured and they are currently undergoing clinical evaluation in hospitals in Switzerland and in the United States.

  1. [Prevention of injuries associated with horseback riding].

    Science.gov (United States)

    ten Kate, Chantal A; de Kooter, Tabitha A; Kramer, William L M

    2015-01-01

    Each year 9,900 equestrians present at Accident and Emergency Departments, 40% of them 10-19 year old females. The most common horse-riding injuries are to the head, brain, neck and face, torso and extremities. Because of the relatively larger head, children more often fall on their head. Wearing a helmet gives considerable protection. Despite the common use of a helmet by horseback riders, serious head injury still occurs regularly. Further research into improvement of the protective function of the helmet is indicated. The current safety vest (body protector) does not significantly reduce the risk of torso injury. Improvement of its protective function is necessary. Injury to the lower extremities is caused when they become trapped in the stirrup in a fall from or with the horse. Safety stirrups and sturdy footwear are possible preventive measures. Investment in the quality and promotion of preventive measures could reduce the frequency and severity of equestrian injuries.

  2. Attenuation correction for freely moving small animal brain PET studies based on a virtual scanner geometry

    International Nuclear Information System (INIS)

    Angelis, G I; Kyme, A Z; Ryder, W J; Fulton, R R; Meikle, S R

    2014-01-01

    Attenuation correction in positron emission tomography brain imaging of freely moving animals is a very challenging problem since the torso of the animal is often within the field of view and introduces a non negligible attenuating factor that can degrade the quantitative accuracy of the reconstructed images. In the context of unrestrained small animal imaging, estimation of the attenuation correction factors without the need for a transmission scan is highly desirable. An attractive approach that avoids the need for a transmission scan involves the generation of the hull of the animal’s head based on the reconstructed motion corrected emission images. However, this approach ignores the attenuation introduced by the animal’s torso. In this work, we propose a virtual scanner geometry which moves in synchrony with the animal’s head and discriminates between those events that traversed only the animal’s head (and therefore can be accurately compensated for attenuation) and those that might have also traversed the animal’s torso. For each recorded pose of the animal’s head a new virtual scanner geometry is defined and therefore a new system matrix must be calculated leading to a time-varying system matrix. This new approach was evaluated on phantom data acquired on the microPET Focus 220 scanner using a custom-made phantom and step-wise motion. Results showed that when the animal’s torso is within the FOV and not appropriately accounted for during attenuation correction it can lead to bias of up to 10% . Attenuation correction was more accurate when the virtual scanner was employed leading to improved quantitative estimates (bias < 2%), without the need to account for the attenuation introduced by the extraneous compartment. Although the proposed method requires increased computational resources, it can provide a reliable approach towards quantitatively accurate attenuation correction for freely moving animal studies. (paper)

  3. The four-dimensional non-uniform rational B-splines-based cardiac-torso phantom and its application in medical imaging research

    International Nuclear Information System (INIS)

    Li Chongguo; Wu Dake; Lang Jinyi

    2008-01-01

    Simulation skill is playing an increasingly important role in medical imaging research. four-dimensional non-uniform rational B-splines-based cardiac-torso (4D NCAT) phantom is new tool for meoical imaging res catch and when combined with accurate models for the imaging process a wealth of realistic imaging data from subjects of various anatomies. Can be provided 4D NCAT phantoms have bend widely used in medical research such as SPECT, PET, CT and so on. 4D NCAT phantoms have also been used in inverse planning system of intensity modulated radiation therapy. (authors)

  4. Comparison of recessed gate-head structures on normally-off AlGaN/GaN high-electron-mobility transistor performance.

    Science.gov (United States)

    Khan, Mansoor Ali; Heo, Jun-Woo; Kim, Hyun-Seok; Park, Hyun-Chang

    2014-11-01

    In this work, different gate-head structures have been compared in the context of AlGaN/GaN-based high-electron-mobility transistors (HEMTs). Field-plate (FP) technology self-aligned to the gate electrode leads to various gate-head structures, most likely gamma (γF)-gate, camel (see symbol)-gate, and mushroom-shaped (T)-gate. In-depth comparison of recessed gate-head structures demonstrated that key performance metrics such as transconductance, output current, and breakdown voltage are better with the T-gate head structure. The recessed T-gate with its one arm toward the source side not only reduces the source-access resistance (R(g) +R(gs)), but also minimizes the source-side dispersion and current leakage, resulting in high transconductance (G(m)) and output current (I(DS)). At the same time, the other arm toward the drain-side reduces the drain-side dispersion and tends to distribute electric field peaks uniformly, resulting in high breakdown voltage (V(BR)). DC and RF analysis showed that the recessed T-gate FP-HEMT is a suitable candidate not only for high-frequency operation, but also for high-power applications.

  5. Evolution of robotic arms.

    Science.gov (United States)

    Moran, Michael E

    2007-01-01

    The foundation of surgical robotics is in the development of the robotic arm. This is a thorough review of the literature on the nature and development of this device with emphasis on surgical applications. We have reviewed the published literature and classified robotic arms by their application: show, industrial application, medical application, etc. There is a definite trend in the manufacture of robotic arms toward more dextrous devices, more degrees-of-freedom, and capabilities beyond the human arm. da Vinci designed the first sophisticated robotic arm in 1495 with four degrees-of-freedom and an analog on-board controller supplying power and programmability. von Kemplen's chess-playing automaton left arm was quite sophisticated. Unimate introduced the first industrial robotic arm in 1961, it has subsequently evolved into the PUMA arm. In 1963 the Rancho arm was designed; Minsky's Tentacle arm appeared in 1968, Scheinman's Stanford arm in 1969, and MIT's Silver arm in 1974. Aird became the first cyborg human with a robotic arm in 1993. In 2000 Miguel Nicolalis redefined possible man-machine capacity in his work on cerebral implantation in owl-monkeys directly interfacing with robotic arms both locally and at a distance. The robotic arm is the end-effector of robotic systems and currently is the hallmark feature of the da Vinci Surgical System making its entrance into surgical application. But, despite the potential advantages of this computer-controlled master-slave system, robotic arms have definite limitations. Ongoing work in robotics has many potential solutions to the drawbacks of current robotic surgical systems.

  6. Effect of head-only sub-chronic GSM exposure on spatial memory of rats

    International Nuclear Information System (INIS)

    Ammari, Mohamed; Brillaud, Elsa; Lecomte, Anthony; Sakly, Mohsen; Abdelmelek, Hafedh; Seze, Rene de; Faculte des Sciences de Bizerte, Jarzouna

    2008-01-01

    Full text: Introduction: Low power electromagnetic fields (EMF) are suspected to produce deficit memory in rats. The study of Dubreuil et al (2003) showed that a short-term (10-15 days) exposure 'head-only' to GSM 900 MHz radio frequencies does not produce a deficit memory in adult rats. The aim of our experiment was to determine if head-only sub-chronic exposure (2 months) of rats to GSM signal for 45 min at a SAR = 1.5 W/Kg and for 15 min at 6 W/Kg induce deficit in spatial memory of rats in radial maze test. Materials and methods: Exposure system: Animals were placed in Plexiglas rockets with an individual loop antenna placed above the rat's head. Four animals were exposed at the time. Loop antennas were connected to a generator and emitted a GSM signal (900 MHz, pulsed at 217 Hz, 1/8 duty factor) 5 days / week for 8 weeks. Experimental group: 30 Sprague-Dawley male rats were randomly assigned to 5 different groups: a) 6 rats exposed 15 min at SAR = 6 W/Kg; b) 6 rats exposed 45 min at SAR = 1.5 W/g; c) 6 rats sham controls (3 for 5 min and 3 for 45 min, SAR = 0 W/Kg); d) 6 rats without any treatment and manipulation (cage control); e) 6 rats were injected (i.p) S.B.H 0.1 mg/Kg (Sigma Aldrich) as positive control group. Behavioural procedure: The radial maze protocol consists of two consecutive phases: the training task (10 days) and the test task (8 days). In the first phase, rats were trained to visit the 8 arms of the maze without returning to an arm already visited. In the second phase (8 days), a 45-min intra-trial delay was introduced after four visited arms. After the intra-delay, the rat was placed in the maze to finish the test task, which is visiting four other arms he had not visited. During the training task, exposure took place before the behavioural task. During the test task, exposure or sham-exposure took place during the intra-delay. Results and discussion: In all experiments, performance of exposed rats (1.5 and 6 W/Kg) was compared with that of

  7. Injury Source and Correlation Analysis of Riders in Car-Electric Bicycle Accidents

    Directory of Open Access Journals (Sweden)

    Tiefang Zou

    2018-01-01

    Full Text Available The knowledge about the injury source and correlation of riders in car-electric bicycle accident will be helpful in the cross validation of traces and vehicle safety design. In order to know more information about such kind of knowledge, 57 true car-electric bicycle accidents were reconstructed by PC-Crash and then data on injury information of riders were collected directly from the reconstructed cases. These collected data were validated by some existing research results firstly, and then 4 abnormal cases were deleted according to the statistical method. Finally, conclusions can be obtained according to the data obtained from the remaining 53 cases. Direct injuries of the head and right leg are from the road pavement upon low speed; the source laws of indirect head injuries are not obvious. Upon intermediate and high speed, the injuries of the above parts are from automobiles. Injuries of the left leg, femur, and right knee are from automobiles; left knee injuries are from automobiles, the road pavement and automobiles, respectively, upon low, intermediate, and high speed. The source laws of indirect torso injuries are not obvious upon intermediate and low speed, which are from automobiles upon high speed, while direct torso injuries are from the road pavement. And there is no high correlation between all parts of the injury of riders. The largest correlation coefficient was the head-left femur and left femur-right femur, which was 0.647, followed by the head-right femur (0.638 and head-torso which was 0.617.

  8. Injury Source and Correlation Analysis of Riders in Car-Electric Bicycle Accidents.

    Science.gov (United States)

    Zou, Tiefang; Yi, Liang; Cai, Ming; Hu, Lin; Li, Yuelin

    2018-01-01

    The knowledge about the injury source and correlation of riders in car-electric bicycle accident will be helpful in the cross validation of traces and vehicle safety design. In order to know more information about such kind of knowledge, 57 true car-electric bicycle accidents were reconstructed by PC-Crash and then data on injury information of riders were collected directly from the reconstructed cases. These collected data were validated by some existing research results firstly, and then 4 abnormal cases were deleted according to the statistical method. Finally, conclusions can be obtained according to the data obtained from the remaining 53 cases. Direct injuries of the head and right leg are from the road pavement upon low speed; the source laws of indirect head injuries are not obvious. Upon intermediate and high speed, the injuries of the above parts are from automobiles. Injuries of the left leg, femur, and right knee are from automobiles; left knee injuries are from automobiles, the road pavement and automobiles, respectively, upon low, intermediate, and high speed. The source laws of indirect torso injuries are not obvious upon intermediate and low speed, which are from automobiles upon high speed, while direct torso injuries are from the road pavement. And there is no high correlation between all parts of the injury of riders. The largest correlation coefficient was the head-left femur and left femur-right femur, which was 0.647, followed by the head-right femur (0.638) and head-torso which was 0.617.

  9. Precursor B-cell lymphoblastic leukemia of the arm mimicking neurogenic tumor: case report

    Directory of Open Access Journals (Sweden)

    Sui Xiu-fang

    2012-07-01

    Full Text Available Abstract Precursor B-cell lymphoblastic lymphoma (PBLL is an infrequent subtype of lymphoblastic lymphoma (LBL that commonly affected site for the diagnosis is the skin, followed by the head and neck. In this report, we presented a special case of PBLL located at the left arm and detected with magnetic resonance imaging (MRI and ultrasonography (US. This kind of PBLL is similar to a peripheral nerve tumor in clinical and radiographic manifestation.

  10. On the need to revise the arm structure in stylized anthropomorphic phantoms in lateral photon irradiation geometry

    International Nuclear Information System (INIS)

    Lee, Choonsik; Lee, Choonik; Lee, Jai-Ki

    2006-01-01

    -Man, were obtained from literature sources. The absorbed doses for lungs, oesophagus, liver and kidneys that could be affected by arm structures in the lateral irradiation geometry were obtained for both classes of phantoms in lateral monoenergetic photon irradiation geometries. As expected, those organs in the ORNL phantoms received apparently higher absorbed doses than those in the voxel phantoms. The overestimation is mainly attributed to the relatively poor representation of the arm structure in the ORNL phantom in which the arm bones are embedded within the regions describing the phantom's torso. The results of this study suggest that the overestimation of organ doses, due to unrealistic arm representation, should be taken into account when stylized phantoms are employed for equivalent or effective dose estimates, especially in the case of an irradiation scenario with dominating lateral exposure. For such a reason, the stylized phantom arm structure definition should be revised in order to obtain more realistic evaluations. (note)

  11. Skeletomusculature of Scelionidae (Hymenoptera: Platygastroidea): head and mesosoma

    DEFF Research Database (Denmark)

    Miko, I.; Vilhelmsen, Lars; Johnson, N.F.

    2007-01-01

    is proposed. External characters are redescribed and correlated with corresponding apodemes, muscles and putative exocrine gland openings; their phylogenetic importance is discussed. 229 skeletal structures were termed and defined, from which 84 are newly established or redefined. 67 muscles of the head...... of the site of origin of the mesopleuro-mesobasalare muscle. The term speculum is adopted from Ichneumonidae and Cynipoidea taxonomy on the basis of the site of origin of the mesopleuro-mesofurcal muscle. The remnants of the mesopleural ridge, sulcus and mesopleural arm and pit and the putative border between...... with corresponding apodemes, muscles and putative exocrine gland openings; their phylogenetic importance is discussed. 229 skeletal structures were termed and defined, from which 84 are newly established or redefined. 67 muscles of the head and mesosoma are examined and homologized with those present in other...

  12. Isolated effects of peripheral arm and central body cooling on arm performance.

    Science.gov (United States)

    Giesbrecht, G G; Wu, M P; White, M D; Johnston, C E; Bristow, G K

    1995-10-01

    Whole body cooling impairs manual arm performance. The independent contributions of local (peripheral) and/or whole body (central) cooling are not known. Therefore, a protocol was developed in which the arm and the rest of the body could be independently cooled. Biceps temperature (Tmus), at a depth of 20 mm, and esophageal temperature (Tes) were measured. Six subjects were immersed to the clavicles in a tank (body tank) of water under 3 conditions: 1) cold body-cold arm (CB-CA); 2) warm body-cold arm (WB-CA); and 3) cold body-warm arm (CB-WA). In the latter two conditions, subjects placed their dominant arm in a separate (arm) tank. Water temperature (Tw) in each tank was independently controlled. In conditions requiring cold body and/or cold arm, Tw in the appropriate tanks was 8 degrees C. In conditions requiring warm body and/or warm arm, Tw in the appropriate tanks was adjusted between 29 and 38 degrees C to maintain body/arm temperature at baseline values. A battery of 6 tests, requiring fine or gross motor movements, were performed immediately before immersion and after 15, 45, and 70 minutes of immersion. In CB-CA, Tes decreased from an average of 37.2 to 35.6 degrees C and Tmus decreased from 34.6 to 22.0 degrees C. In WB-CA, Tmus decreased to 18.1 degrees C (Tes = 37.1 degrees C), and in CB-WA, Tes decreased to 35.8 degrees C (Tmus = 34.5 degrees C). By the end of immersion, there were significant decrements (43-85%) in the performance of all tests in CB-CA and WB-CA (p body and/or the arm elicits large decrements in finger, hand and arm performance. The decrements are due almost entirely to the local effects of arm tissue cooling.

  13. SU-E-J-12: An Image-Guided Soft Robotic Patient Positioning System for Maskless Head-And-Neck Cancer Radiotherapy: A Proof-Of-Concept Study

    International Nuclear Information System (INIS)

    Ogunmolu, O; Gans, N; Jiang, S; Gu, X

    2015-01-01

    Purpose: We propose a surface-image-guided soft robotic patient positioning system for maskless head-and-neck radiotherapy. The ultimate goal of this project is to utilize a soft robot to realize non-rigid patient positioning and real-time motion compensation. In this proof-of-concept study, we design a position-based visual servoing control system for an air-bladder-based soft robot and investigate its performance in controlling the flexion/extension cranial motion on a mannequin head phantom. Methods: The current system consists of Microsoft Kinect depth camera, an inflatable air bladder (IAB), pressured air source, pneumatic valve actuators, custom-built current regulators, and a National Instruments myRIO microcontroller. The performance of the designed system was evaluated on a mannequin head, with a ball joint fixed below its neck to simulate torso-induced head motion along flexion/extension direction. The IAB is placed beneath the mannequin head. The Kinect camera captures images of the mannequin head, extracts the face, and measures the position of the head relative to the camera. This distance is sent to the myRIO, which runs control algorithms and sends actuation commands to the valves, inflating and deflating the IAB to induce head motion. Results: For a step input, i.e. regulation of the head to a constant displacement, the maximum error was a 6% overshoot, which the system then reduces to 0% steady-state error. In this initial investigation, the settling time to reach the regulated position was approximately 8 seconds, with 2 seconds of delay between the command start of motion due to capacitance of the pneumatics, for a total of 10 seconds to regulate the error. Conclusion: The surface image-guided soft robotic patient positioning system can achieve accurate mannequin head flexion/extension motion. Given this promising initial Result, the extension of the current one-dimensional soft robot control to multiple IABs for non-rigid positioning control

  14. SU-E-J-12: An Image-Guided Soft Robotic Patient Positioning System for Maskless Head-And-Neck Cancer Radiotherapy: A Proof-Of-Concept Study

    Energy Technology Data Exchange (ETDEWEB)

    Ogunmolu, O; Gans, N [The University of Texas at Dallas, Richardson, TX (United States); Jiang, S; Gu, X [UT Southwestern Medical Center, Dallas, TX (United States)

    2015-06-15

    Purpose: We propose a surface-image-guided soft robotic patient positioning system for maskless head-and-neck radiotherapy. The ultimate goal of this project is to utilize a soft robot to realize non-rigid patient positioning and real-time motion compensation. In this proof-of-concept study, we design a position-based visual servoing control system for an air-bladder-based soft robot and investigate its performance in controlling the flexion/extension cranial motion on a mannequin head phantom. Methods: The current system consists of Microsoft Kinect depth camera, an inflatable air bladder (IAB), pressured air source, pneumatic valve actuators, custom-built current regulators, and a National Instruments myRIO microcontroller. The performance of the designed system was evaluated on a mannequin head, with a ball joint fixed below its neck to simulate torso-induced head motion along flexion/extension direction. The IAB is placed beneath the mannequin head. The Kinect camera captures images of the mannequin head, extracts the face, and measures the position of the head relative to the camera. This distance is sent to the myRIO, which runs control algorithms and sends actuation commands to the valves, inflating and deflating the IAB to induce head motion. Results: For a step input, i.e. regulation of the head to a constant displacement, the maximum error was a 6% overshoot, which the system then reduces to 0% steady-state error. In this initial investigation, the settling time to reach the regulated position was approximately 8 seconds, with 2 seconds of delay between the command start of motion due to capacitance of the pneumatics, for a total of 10 seconds to regulate the error. Conclusion: The surface image-guided soft robotic patient positioning system can achieve accurate mannequin head flexion/extension motion. Given this promising initial Result, the extension of the current one-dimensional soft robot control to multiple IABs for non-rigid positioning control

  15. The Neanderthal lower arm.

    Science.gov (United States)

    De Groote, Isabelle

    2011-10-01

    Neanderthal forearms have been described as being very powerful. Different individual features in the lower arm bones have been described to distinguish Neanderthals from modern humans. In this study, the overall morphology of the radius and ulna is considered, and morphological differences among Neanderthals, Upper Paleolithic Homo sapiens and recent H. sapiens are described. Comparisons among populations were made using a combination of 3D geometric morphometrics and standard multivariate methods. Comparative material included all available complete radii and ulnae from Neanderthals, early H. sapiens and archaeological and recent human populations, representing a wide geographical and lifestyle range. There are few differences among the populations when features are considered individually. Neanderthals and early H. sapiens fell within the range of modern human variation. When the suite of measurements and shapes were analyzed, differences and similarities became apparent. The Neanderthal radius is more laterally curved, has a more medially placed radial tuberosity, a longer radial neck, a more antero-posteriorly ovoid head and a well-developed proximal interosseous crest. The Neanderthal ulna has a more anterior facing trochlear notch, a lower M. brachialis insertion, larger relative mid-shaft size and a more medio-lateral and antero-posterior sinusoidal shaft. The Neanderthal lower arm morphology reflects a strong cold-adapted short forearm. The forearms of H. sapiens are less powerful in pronation and supination. Many differences between Neanderthals and H. sapiens can be explained as a secondary consequence of the hyper-polar body proportions of the Neanderthals, but also as retentions of the primitive condition of other hominoids. Copyright © 2011 Elsevier Ltd. All rights reserved.

  16. Have Third-World Arms Industries Reduced Arms Imports?

    OpenAIRE

    Looney, R.E.

    1989-01-01

    Current Research on Peace and Violence, no. 1, 1989. Refereed Journal Article In 1945 only Argentina, Brazil, India and South Africa in the Third World possessed domestic arms industries which produced weapons systems other than small arms and ammunition (SIPRI, 1987, 76).

  17. NOTE: On the need to revise the arm structure in stylized anthropomorphic phantoms in lateral photon irradiation geometry

    Science.gov (United States)

    Lee, Choonsik; Lee, Choonik; Lee, Jai-Ki

    2006-11-01

    -Man, were obtained from literature sources. The absorbed doses for lungs, oesophagus, liver and kidneys that could be affected by arm structures in the lateral irradiation geometry were obtained for both classes of phantoms in lateral monoenergetic photon irradiation geometries. As expected, those organs in the ORNL phantoms received apparently higher absorbed doses than those in the voxel phantoms. The overestimation is mainly attributed to the relatively poor representation of the arm structure in the ORNL phantom in which the arm bones are embedded within the regions describing the phantom's torso. The results of this study suggest that the overestimation of organ doses, due to unrealistic arm representation, should be taken into account when stylized phantoms are employed for equivalent or effective dose estimates, especially in the case of an irradiation scenario with dominating lateral exposure. For such a reason, the stylized phantom arm structure definition should be revised in order to obtain more realistic evaluations.

  18. Trunk muscle activation. The effects of torso flexion, moment direction, and moment magnitude.

    Science.gov (United States)

    Lavender, S; Trafimow, J; Andersson, G B; Mayer, R S; Chen, I H

    1994-04-01

    This study was performed to quantify the electromyographic trunk muscle activities in response to variations in moment magnitude and direction while in forward-flexed postures. Recordings were made over eight trunk muscles in 19 subjects who maintained forward-flexed postures of 30 degrees and 60 degrees. In each of the two flexed postures, external moments of 20 Nm and 40 Nm were applied via a chest harness. The moment directions were varied in seven 30 degrees increments to a subject's right side, such that the direction of the applied load ranged from the upper body's anterior midsagittal plane (0 degree) to the posterior midsagittal plane (180 degrees). Statistical analyses yielded significant moment magnitude by moment-direction interaction effects for the EMG output from six of the eight muscles. Trunk flexion by moment-direction interactions were observed in the responses from three muscles. In general, the primary muscle supporting the torso and the applied load was the contralateral (left) erector spinae. The level of electromyographic activity in the anterior muscles was quite low, even with the posterior moment directions.

  19. Arm Pain

    Science.gov (United States)

    ... be a sign of a heart attack. Seek emergency treatment if you have: Arm, shoulder or back ... http://www.mayoclinic.org/symptoms/arm-pain/basics/definition/SYM-20050870 . Mayo Clinic Footer Legal Conditions and ...

  20. TU-FG-BRB-11: Design and Evaluation of a Robotic C-Arm CBCT System for Image-Guided Proton Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Hua, C; Yao, W; Farr, J; Merchant, T [St. Jude Children’s Research Hospital, Memphis, TN (United States); Kidani, T; Tomida, K; Ozawa, S; Nishimura, T; Fujusawa, T; Shinagawa, R [Hitachi, Ltd., Hitachi-shi, Ibaraki-ken (Japan)

    2016-06-15

    Purpose: To describe the design and performance of a ceiling-mounted robotic C-arm CBCT system for image-guided proton therapy. Methods: Uniquely different from traditional C-arm CBCT used in interventional radiology, the imaging system was designed to provide volumetric image guidance for patients treated on a 190-degree proton gantry system and a 6 degree-of-freedom (DOF) robotic patient positioner. The mounting of robotic arms to the ceiling rails, rather than gantry or nozzle, provides the flexibility in imaging locations (isocenter, iso+27cm in X, iso+100cm in Y) in the room and easier upgrade as technology advances. A kV X-ray tube and a 43×43cm flat panel imager were mounted to a rotating C-ring (87cm diameter), which is coupled to the C-arm concentrically. Both C-arm and the robotic arm remain stationary during imaging to maintain high position accuracy. Source-to-axis distance and source-to-imager distance are 100 and 150cm, respectively. A 14:1 focused anti-scatter grid and a bowtie filer are used for image acquisition. A unique automatic collimator device of 4 independent blades for adjusting field of view and reducing patient dose has also been developed. Results: Sub-millimeter position accuracy and repeatability of the robotic C-arm were measured with a laser tracker. High quality CBCT images for positioning can be acquired with a weighted CTDI of 3.6mGy (head in 200° full fan mode: 100kV, 20mA, 20ms, 10fps)-8.7 mGy (pelvis in 360° half fan mode: 125kV, 42mA, 20ms, 10fps). Image guidance accuracy achieved <1mm (3D vector) with automatic 3D-3D registration for anthropomorphic head and pelvis phantoms. Since November 2015, 22 proton therapy patients have undergone daily CBCT imaging for 6 DOF positioning. Conclusion: Decoupled from gantry and nozzle, this CBCT system provides a unique solution for volumetric image guidance with half/partial proton gantry systems. We demonstrated that daily CBCT can be integrated into proton therapy for pre

  1. TU-FG-BRB-11: Design and Evaluation of a Robotic C-Arm CBCT System for Image-Guided Proton Therapy

    International Nuclear Information System (INIS)

    Hua, C; Yao, W; Farr, J; Merchant, T; Kidani, T; Tomida, K; Ozawa, S; Nishimura, T; Fujusawa, T; Shinagawa, R

    2016-01-01

    Purpose: To describe the design and performance of a ceiling-mounted robotic C-arm CBCT system for image-guided proton therapy. Methods: Uniquely different from traditional C-arm CBCT used in interventional radiology, the imaging system was designed to provide volumetric image guidance for patients treated on a 190-degree proton gantry system and a 6 degree-of-freedom (DOF) robotic patient positioner. The mounting of robotic arms to the ceiling rails, rather than gantry or nozzle, provides the flexibility in imaging locations (isocenter, iso+27cm in X, iso+100cm in Y) in the room and easier upgrade as technology advances. A kV X-ray tube and a 43×43cm flat panel imager were mounted to a rotating C-ring (87cm diameter), which is coupled to the C-arm concentrically. Both C-arm and the robotic arm remain stationary during imaging to maintain high position accuracy. Source-to-axis distance and source-to-imager distance are 100 and 150cm, respectively. A 14:1 focused anti-scatter grid and a bowtie filer are used for image acquisition. A unique automatic collimator device of 4 independent blades for adjusting field of view and reducing patient dose has also been developed. Results: Sub-millimeter position accuracy and repeatability of the robotic C-arm were measured with a laser tracker. High quality CBCT images for positioning can be acquired with a weighted CTDI of 3.6mGy (head in 200° full fan mode: 100kV, 20mA, 20ms, 10fps)-8.7 mGy (pelvis in 360° half fan mode: 125kV, 42mA, 20ms, 10fps). Image guidance accuracy achieved <1mm (3D vector) with automatic 3D-3D registration for anthropomorphic head and pelvis phantoms. Since November 2015, 22 proton therapy patients have undergone daily CBCT imaging for 6 DOF positioning. Conclusion: Decoupled from gantry and nozzle, this CBCT system provides a unique solution for volumetric image guidance with half/partial proton gantry systems. We demonstrated that daily CBCT can be integrated into proton therapy for pre

  2. Whiplash and prevention.

    NARCIS (Netherlands)

    2008-01-01

    A whiplash is caused by a sudden and violent movement of the head in relation to the torso. Whiplash injury is a combination of pain in the neck, pain in the head, and other health complaints. Annually, an estimated 30,000 to 50,000 people in the Netherlands incur whiplash due to a traffic crash,

  3. Pesticide risk assessment in flower greenhouses in Argentina: The importance of manipulating concentrated products

    Energy Technology Data Exchange (ETDEWEB)

    Flores, Andrea P.; Berenstein, Giselle A.; Hughes, Enrique A.; Zalts, Anita [Instituto de Ciencias, Universidad Nacional de General Sarmiento (UNGS), J.M. Gutierrez 1150, (B1613GSX) Los Polvorines, Prov. de Buenos Aires (Argentina); Montserrat, Javier M., E-mail: jmontser@ungs.edu.ar [Instituto de Ciencias, Universidad Nacional de General Sarmiento (UNGS), J.M. Gutierrez 1150, (B1613GSX) Los Polvorines, Prov. de Buenos Aires (Argentina); Instituto de Investigaciones en Ingenieria Genetica y Biologia Molecular (CONICET), Vuelta de Obligado 2490, 2o piso, Buenos Aires (Argentina)

    2011-05-15

    An evaluation of the Potential Dermal Exposure of workers to endosulfan and procymidone at the mix/load and application stages was done in small floricultural production units in Argentina. Seven experiments were performed with different operators under typical greenhouse conditions, based on the whole body dosimetry methodology. These results indicate that the mean Potential Dermal Exposure of the application step was 45.0 {+-} 55.0 mL h{sup -1} with the highest proportion on torso, head, arms and hands. When the mix/load and application stages were compared, the first was found to contribute the most to the total exposure. Also, the Margin of Safety for the different operations was calculated, and a pesticide surrogate was developed and used to make comparative evaluations of hand exposure for different groups of operators. These results emphasize the importance of the mix/load stage in the exposure process.

  4. Digging up Von Békésy: Funneling of Touches around the Body

    Directory of Open Access Journals (Sweden)

    Lisa M Pritchett

    2011-10-01

    Full Text Available We investigated a technique that can be used to place tactile stimuli on a continuum between two points using two tactors placed several centimeters apart. As von Békésy first described in 1959, when two pieces of skin several centimeters apart are simultaneously stimulated, a single touch is perceived at an intermediate location. When the relative intensity of the vibration of the two tactors is slowly adjusted from 1:0 to 0:1 a sensation is created of a touch moving across the skin. This has come to be known as the funneling illusion. We have characterized the funneling illusion on a variety of body parts including the hand, arm, wrist, head, torso, and legs. We show that the illusion is robust to a variety of vibration parameters, and demonstrate how it may be used for within modality touch discrimination and adjustment procedures.

  5. Pesticide risk assessment in flower greenhouses in Argentina: The importance of manipulating concentrated products

    International Nuclear Information System (INIS)

    Flores, Andrea P.; Berenstein, Giselle A.; Hughes, Enrique A.; Zalts, Anita; Montserrat, Javier M.

    2011-01-01

    An evaluation of the Potential Dermal Exposure of workers to endosulfan and procymidone at the mix/load and application stages was done in small floricultural production units in Argentina. Seven experiments were performed with different operators under typical greenhouse conditions, based on the whole body dosimetry methodology. These results indicate that the mean Potential Dermal Exposure of the application step was 45.0 ± 55.0 mL h -1 with the highest proportion on torso, head, arms and hands. When the mix/load and application stages were compared, the first was found to contribute the most to the total exposure. Also, the Margin of Safety for the different operations was calculated, and a pesticide surrogate was developed and used to make comparative evaluations of hand exposure for different groups of operators. These results emphasize the importance of the mix/load stage in the exposure process.

  6. Mouse Y-Encoded Transcription Factor Zfy2 Is Essential for Sperm Head Remodelling and Sperm Tail Development

    NARCIS (Netherlands)

    Vernet, Nadege; Mahadevaiah, Shantha K.; Decarpentrie, Fanny; Longepied, Guy; de Rooij, Dirk G.; Burgoyne, Paul S.; Mitchell, Michael J.

    2016-01-01

    A previous study indicated that genetic information encoded on the mouse Y chromosome short arm (Yp) is required for efficient completion of the second meiotic division (that generates haploid round spermatids), restructuring of the sperm head, and development of the sperm tail. Using mouse models

  7. Ipsilateral wrist-ankle movements in the sagittal plane encoded in extrinsic reference frame.

    Science.gov (United States)

    Muraoka, Tetsuro; Ishida, Yuki; Obu, Takashi; Crawshaw, Larry; Kanosue, Kazuyuki

    2013-04-01

    When performing oscillatory movements of two joints in the sagittal plane, there is a directional constraint for performing such movements. Previous studies could not distinguish whether the directional constraint reflected movement direction encoded in the extrinsic (outside the body) reference frame or in the intrinsic (the participants' torso/head) reference frame since participants performed coordinated movements in a sitting position where the torso/head was stationary relative to the external world. In order to discern the reference frame in the present study, participants performed paced oscillatory movements of the ipsilateral wrist and ankle in the sagittal plane in a standing position so that the torso/head moved relative to the external world. The coordinated movements were performed in one of two modes of coordination, moving the hand upward concomitant with either ankle plantarflexion or ankle dorsiflexion. The same directional mode relative to extrinsic space was more stable and accurate as compared with the opposite directional mode. When forearm position was changed from the pronated position to the supinated position, similar results were obtained, indicating that the results were independent of a particular coupling of muscles. These findings suggest that the directional constraint on ipsilateral joints movements in the sagittal plane reflects movement direction encoded in the extrinsic reference frame. Copyright © 2013 Elsevier Ireland Ltd and the Japan Neuroscience Society. All rights reserved.

  8. Head-coupled remote stereoscopic camera system for telepresence applications

    Science.gov (United States)

    Bolas, Mark T.; Fisher, Scott S.

    1990-09-01

    The Virtual Environment Workstation Project (VIEW) at NASA's Ames Research Center has developed a remotely controlled stereoscopic camera system that can be used for telepresence research and as a tool to develop and evaluate configurations for head-coupled visual systems associated with space station telerobots and remote manipulation robotic arms. The prototype camera system consists of two lightweight CCD video cameras mounted on a computer controlled platform that provides real-time pan, tilt, and roll control of the camera system in coordination with head position transmitted from the user. This paper provides an overall system description focused on the design and implementation of the camera and platform hardware configuration and the development of control software. Results of preliminary performance evaluations are reported with emphasis on engineering and mechanical design issues and discussion of related psychophysiological effects and objectives.

  9. Download this PDF file

    African Journals Online (AJOL)

    Test

    2011-06-07

    Jun 7, 2011 ... violence of poverty, the history of Coptic Christianity and the role of women within this tradition. The article touched on aspects such as 'women monks', ... seen was in India where I saw torsos (i.e. persons without arms or legs) ...

  10. Electromechanical and robot-assisted arm training for improving activities of daily living, arm function, and arm muscle strength after stroke.

    Science.gov (United States)

    Mehrholz, Jan; Pohl, Marcus; Platz, Thomas; Kugler, Joachim; Elsner, Bernhard

    2015-11-07

    Electromechanical and robot-assisted arm training devices are used in rehabilitation, and may help to improve arm function after stroke. To assess the effectiveness of electromechanical and robot-assisted arm training for improving activities of daily living, arm function, and arm muscle strength in people after stroke. We also assessed the acceptability and safety of the therapy. We searched the Cochrane Stroke Group's Trials Register (last searched February 2015), the Cochrane Central Register of Controlled Trials (CENTRAL) (the Cochrane Library 2015, Issue 3), MEDLINE (1950 to March 2015), EMBASE (1980 to March 2015), CINAHL (1982 to March 2015), AMED (1985 to March 2015), SPORTDiscus (1949 to March 2015), PEDro (searched April 2015), Compendex (1972 to March 2015), and Inspec (1969 to March 2015). We also handsearched relevant conference proceedings, searched trials and research registers, checked reference lists, and contacted trialists, experts, and researchers in our field, as well as manufacturers of commercial devices. Randomised controlled trials comparing electromechanical and robot-assisted arm training for recovery of arm function with other rehabilitation or placebo interventions, or no treatment, for people after stroke. Two review authors independently selected trials for inclusion, assessed trial quality and risk of bias, and extracted data. We contacted trialists for additional information. We analysed the results as standardised mean differences (SMDs) for continuous variables and risk differences (RDs) for dichotomous variables. We included 34 trials (involving 1160 participants) in this update of our review. Electromechanical and robot-assisted arm training improved activities of daily living scores (SMD 0.37, 95% confidence interval (CI) 0.11 to 0.64, P = 0.005, I² = 62%), arm function (SMD 0.35, 95% CI 0.18 to 0.51, P arm muscle strength (SMD 0.36, 95% CI 0.01 to 0.70, P = 0.04, I² = 72%), but the quality of the evidence was low to very low

  11. Venous reflux on contrast-enhanced head and neck magnetic resonance angiography: Analysis of causative factors

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Dong Jae; Lee, Eun Ja [Dept. of Radiology, Dongguk University Ilsan Hospital, Goyang (Korea, Republic of); Bae, Jong Myon [Dept. of Preventive Medicine, Jeju National University School of Medicine, Jeju (Korea, Republic of)

    2016-12-15

    The purpose of this study was to analyze the causative factors of venous reflux on contrast-enhanced head and neck magnetic resonance angiography. We retrospectively reviewed 150 patients with right-arm injections and 150 patients with left-arm injections. We included the age, gender, body mass index, history of hypertension, and history of diabetes mellitus in the evaluation of all patients. We measured the shortest width of the left or right brachiocephalic vein (BCV), the diameter of the aortic arch, and the distance between the sternum and vertebral body. The relationship between these factors and the venous reflux was analyzed. In patients with venous reflux, we performed qualitative image scoring for suboptimal images. In patients with venous reflux, the image quality of the left-arm injection group was significantly inferior to the image quality of the right-arm injection group. The mean age and the male-to-female ratio of patients with venous reflux were significantly higher than those of patients without venous reflux. In patients receiving the left-arm injection, the mean shortest width of the left BCV was significantly narrower in patients with venous reflux than in patients without venous reflux. A left-arm injection should be avoided, especially in elderly patients, to acquire an optimal image.

  12. Venous reflux on contrast-enhanced head and neck magnetic resonance angiography: Analysis of causative factors

    International Nuclear Information System (INIS)

    Shin, Dong Jae; Lee, Eun Ja; Bae, Jong Myon

    2016-01-01

    The purpose of this study was to analyze the causative factors of venous reflux on contrast-enhanced head and neck magnetic resonance angiography. We retrospectively reviewed 150 patients with right-arm injections and 150 patients with left-arm injections. We included the age, gender, body mass index, history of hypertension, and history of diabetes mellitus in the evaluation of all patients. We measured the shortest width of the left or right brachiocephalic vein (BCV), the diameter of the aortic arch, and the distance between the sternum and vertebral body. The relationship between these factors and the venous reflux was analyzed. In patients with venous reflux, we performed qualitative image scoring for suboptimal images. In patients with venous reflux, the image quality of the left-arm injection group was significantly inferior to the image quality of the right-arm injection group. The mean age and the male-to-female ratio of patients with venous reflux were significantly higher than those of patients without venous reflux. In patients receiving the left-arm injection, the mean shortest width of the left BCV was significantly narrower in patients with venous reflux than in patients without venous reflux. A left-arm injection should be avoided, especially in elderly patients, to acquire an optimal image

  13. ARM Airborne Carbon Measurements (ARM-ACME) and ARM-ACME 2.5 Final Campaign Reports

    Energy Technology Data Exchange (ETDEWEB)

    Biraud, S. C. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Tom, M. S. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sweeney, C. [NOAA Earth Systems Research Lab., Boulder, CO (United States)

    2016-01-01

    We report on a 5-year multi-institution and multi-agency airborne study of atmospheric composition and carbon cycling at the Atmospheric Radiation Measurement (ARM) Climate Research Facility’s Southern Great Plains (SGP) site, with scientific objectives that are central to the carbon-cycle and radiative-forcing goals of the U.S. Global Change Research Program and the North American Carbon Program (NACP). The goal of these measurements is to improve understanding of 1) the carbon exchange of the Atmospheric Radiation Measurement (ARM) SGP region; 2) how CO2 and associated water and energy fluxes influence radiative-forcing, convective processes, and CO2 concentrations over the ARM SGP region, and 3) how greenhouse gases are transported on continental scales.

  14. Fast-neutron therapy in advanced head and neck cancer: a collaborative international randomized trial

    International Nuclear Information System (INIS)

    Maor, Moshe H.; Errington, R. Douglas; Caplan, Richard J.; Griffin, Thomas W.; Laramore, George E.; Parker, Robert G.; Burnison, Michele; Stetz, Joann; Zink, Sandra; Davis, Lawrence W.; Peters, Lester J.

    1995-01-01

    Purpose: To compare the efficacy of fast-neutron radiotherapy with that of conventionally fractionated photon therapy in the management of patients with locally advanced squamous cell carcinoma of the head and neck. Methods and Materials: Patients with Stage III or IV disease were randomized to receive either 20.4 Gy/12 fractions/4 weeks of neutrons or 70 Gy/35 fractions/7 weeks of photons (control). Between April 1986 and March 1991, 178 patients were entered, 169 of whom were eligible for analysis. The treatment arms were balanced for age, stage, and performance status, but not for primary site of origin. Results: Complete response occurred in 70 and 52% with neutrons and photons, respectively (p = 0.006). Local regional failure at 3 years for all patients was 63% for neutrons and 68% for photons. Actuarial overall survival curves were virtually identical in both study arms, falling to 27% at 3 years. Acute toxicity was similar in the two arms, but late grade 3-5 toxicity was 40% with neutrons compared to 18% with photons (p = 0.008). Conclusion: Although the initial response rate was higher with neutrons, permanent local control and survival were not improved, and the incidence of late normal tissue toxicity was increased. As a result, fast-neutron therapy for advanced squamous cell carcinoma of the head and neck can only be recommended for patients in whom the logistic benefit of treatment in 12 sessions over 4 weeks outweighs the increased risk of late toxicity

  15. Fast-neutron therapy in advanced head and neck cancer: a collaborative international randomized trial

    Energy Technology Data Exchange (ETDEWEB)

    Maor, Moshe H; Errington, R Douglas; Caplan, Richard J; Griffin, Thomas W; Laramore, George E; Parker, Robert G; Burnison, Michele; Stetz, Joann; Zink, Sandra; Davis, Lawrence W; Peters, Lester J

    1995-06-15

    Purpose: To compare the efficacy of fast-neutron radiotherapy with that of conventionally fractionated photon therapy in the management of patients with locally advanced squamous cell carcinoma of the head and neck. Methods and Materials: Patients with Stage III or IV disease were randomized to receive either 20.4 Gy/12 fractions/4 weeks of neutrons or 70 Gy/35 fractions/7 weeks of photons (control). Between April 1986 and March 1991, 178 patients were entered, 169 of whom were eligible for analysis. The treatment arms were balanced for age, stage, and performance status, but not for primary site of origin. Results: Complete response occurred in 70 and 52% with neutrons and photons, respectively (p = 0.006). Local regional failure at 3 years for all patients was 63% for neutrons and 68% for photons. Actuarial overall survival curves were virtually identical in both study arms, falling to 27% at 3 years. Acute toxicity was similar in the two arms, but late grade 3-5 toxicity was 40% with neutrons compared to 18% with photons (p = 0.008). Conclusion: Although the initial response rate was higher with neutrons, permanent local control and survival were not improved, and the incidence of late normal tissue toxicity was increased. As a result, fast-neutron therapy for advanced squamous cell carcinoma of the head and neck can only be recommended for patients in whom the logistic benefit of treatment in 12 sessions over 4 weeks outweighs the increased risk of late toxicity.

  16. The nature of arm movement in children with cerebral palsy when using computer-generated exercise games.

    Science.gov (United States)

    Weightman, Andrew; Preston, Nick; Levesley, Martin; Bhakta, Bipin; Holt, Raymond; Mon-Williams, Mark

    2014-05-01

    To compare upper limb kinematics of children with spastic cerebral palsy (CP) using a passive rehabilitation joystick with those of adults and able-bodied children, to better understand the design requirements of computer-based rehabilitation devices. A blocked comparative study involving seven children with spastic CP, nine able-bodied adults and nine able-bodied children, using a joystick system to play a computer game whilst the kinematics of their upper limb were recorded. The translational kinematics of the joystick's end point and the participant's shoulder movement (protraction/retraction) and elbow rotational kinematics (flexion/extension) were analysed for each group. Children with spastic CP matched their able-bodied peers in the time taken to complete the computer task, but this was due to a failure to adhere to the task instructions of travelling along a prescribed straight line when moving between targets. The spastic CP group took longer to initiate the first movement, which showed jerkier trajectories and demonstrated qualitatively different movement patterns when using the joystick, with shoulder movements that were significantly of greater magnitude than the able-bodied participants. Children with spastic CP generate large shoulder and hence trunk movements when using a joystick to undertake computer-generated arm exercises. This finding has implications for the development and use of assistive technologies to encourage exercise and the instructions given to users of such systems. A kinematic analysis of upper limb function of children with CP when using joystick devices is presented. Children with CP may use upper body movements to compensate for limitations in voluntary shoulder and elbow movements when undertaking computer games designed to encourage the practice of arm movement. The design of rehabilitative computer exercise systems should consider movement of the torso/shoulder as it may have implications for the quality of therapy in the

  17. The analysis of spatial relationship between the rotator cuff and the subacromial space in different arm positions

    International Nuclear Information System (INIS)

    Zou Yuefen; Wang Dehang; Wang Xiaoning; Li Shener

    2003-01-01

    Objective: To explore the distance between the acromion and the humerus head at different arm abduction to observe whether it changes or not, to determine at which position the distance is smallest, and to evaluate the relationship between the subacromial space and the rotator cuff. Methods: Fifteen normal volunteers were examined with MRI in six arm positions, and the coronal thin images were obtained with a spin echo sequence. Using a special positioning device, the arm was placed at 0 degree, 30 degree, 60 degree, 90 degree, 120 degree and 150 degree arm abduction, respectively. Of them, 0 degree-90 degree positions were not rotated, while 120 degree and 150 degree positions were slight internal rotated. The minimal distance of acromion-humerus (A-H) and clavicle-humerus (C-H), and the spatial relationship between the rotator cuff and the subacromial space were measured and observed. Results: The values of A-H and C-H at 60 degree - 150 degree arm abduction were obviously smaller than those at 0 degree-30 degree arm abduction (P 0.05). The rotator cuff (mainly supraspinatus tendon) just went through between the acromion and the humerus at 60 degree - 120 degree arm positions but not at 0 degree, 30 degree and 150 degree arm positions. So at 60 degree - 120 degree arm positions, rotator cuff between the humerus and the acromion was often impinged. Conclusion: The closest contact between the supraspinatus tendon and subacromial space occurs at 60 degree - 120 degree abduction. The findings testify that the patients with impingement syndrome have shoulder pain at 60 degree - 120 degree abduction in clinic from etiology and pathology. In the future, MRI-based analyses should allow investigating the morphological basis of the impingement syndrome, choosing the appropriate therapy, and minimizing failure rates of surgery

  18. Powered manipulator control arm

    International Nuclear Information System (INIS)

    Le Mouee, Theodore; Vertut, Jean; Marchal, Paul; Germon, J.C.; Petit, Michel

    1975-01-01

    A remote operated control arm for powered manipulators is described. It includes an assembly allowing several movements with position sensors for each movement. The number of possible arm movements equals the number of possible manipulator movements. The control systems may be interrupted as required. One part of the arm is fitted with a system to lock it with respect to another part of the arm without affecting the other movements, so long as the positions of the manipulator and the arm have not been brought into complete coincidence. With this system the locking can be ended when complete concordance is achieved [fr

  19. Mild evaporative cooling applied to the torso provides thermoregulatory benefits during running in the heat.

    Science.gov (United States)

    Filingeri, D; Fournet, D; Hodder, S; Havenith, G

    2015-06-01

    We investigated the effects of mild evaporative cooling applied to the torso, before or during running in the heat. Nine male participants performed three trials: control-no cooling (CTR), pre-exercise cooling (PRE-COOL), and during-exercise cooling (COOL). Trials consisted of 10-min neutral exposure and 50-min heat exposure (30 °C; 44% humidity), during which a 30-min running protocol (70% VO2max ) was performed. An evaporative cooling t-shirt was worn before the heat exposure (PRE-COOL) or 15 min after the exercise was started (COOL). PRE-COOL significantly lowered local skin temperature (Tsk ) (up to -5.3 ± 0.3 °C) (P benefits during exercise in the heat. However, the timing of application was critical in inducing different thermoregulatory responses. These findings provide novel insights on the thermoregulatory role of Tsk during exercise in the heat. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. ARM Airborne Carbon Measurements VI (ARM-ACME VI) Field Campaign Report

    Energy Technology Data Exchange (ETDEWEB)

    Biraud, Sebastien [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2017-05-01

    From October 1, 2015 through September 30, 2016, AAF deployed a Cessna 206 aircraft over the Southern Great Plains, collecting observations of trace gas mixing ratios over the ARM/SGP Central Facility. The aircraft payload included two Atmospheric Observing Systems (AOS Inc.) analyzers for continuous measurements of CO2, and a 12-flask sampler for analysis of carbon cycle gases (CO2, CO, CH4, N2O, 13CO2). The aircraft payload also includes solar/infrared radiation measurements. This research (supported by DOE ARM and TES programs) builds upon previous ARM-ACME missions. The goal of these measurements is to improve understanding of: (a) the carbon exchange of the ARM region; (b) how CO2 and associated water and energy fluxes influence radiative forcing, convective processes, and CO2 concentrations over the ARM region, and (c) how greenhouse gases are transported on continental scales.

  1. ARM Mentor Selection Process

    Energy Technology Data Exchange (ETDEWEB)

    Sisterson, D. L. [Argonne National Lab. (ANL), Argonne, IL (United States)

    2015-10-01

    The Atmospheric Radiation Measurement (ARM) Program was created in 1989 with funding from the U.S. Department of Energy (DOE) to develop several highly instrumented ground stations to study cloud formation processes and their influence on radiative transfer. In 2003, the ARM Program became a national scientific user facility, known as the ARM Climate Research Facility. This scientific infrastructure provides for fixed sites, mobile facilities, an aerial facility, and a data archive available for use by scientists worldwide through the ARM Climate Research Facility—a scientific user facility. The ARM Climate Research Facility currently operates more than 300 instrument systems that provide ground-based observations of the atmospheric column. To keep ARM at the forefront of climate observations, the ARM infrastructure depends heavily on instrument scientists and engineers, also known as lead mentors. Lead mentors must have an excellent understanding of in situ and remote-sensing instrumentation theory and operation and have comprehensive knowledge of critical scale-dependent atmospheric processes. They must also possess the technical and analytical skills to develop new data retrievals that provide innovative approaches for creating research-quality data sets. The ARM Climate Research Facility is seeking the best overall qualified candidate who can fulfill lead mentor requirements in a timely manner.

  2. Head pain referral during examination of the neck in migraine and tension-type headache.

    Science.gov (United States)

    Watson, Dean H; Drummond, Peter D

    2012-09-01

    To investigate if and to what extent typical head pain can be reproduced in tension-type headache (TTH), migraine without aura sufferers, and controls when sustained pressure was applied to the lateral posterior arch of C1 and the articular pillar of C2, stressing the atlantooccipital and C2-3 segments respectively. Occipital and neck symptoms often accompany primary headache, suggesting involvement of cervical afferents in central pain processing mechanisms in these disorders. Referral of head pain from upper cervical structures is made possible by convergence of cervical and trigeminal nociceptive afferent information in the trigemino-cervical nucleus. Upper cervical segmental and C2-3 zygapophysial joint dysfunction is recognized as a potential source of noxious afferent information and is present in primary headache sufferers. Furthermore, referral of head pain has been demonstrated from symptomatic upper cervical segments and the C2-3 zygapophysial joints, suggesting that head pain referral may be a characteristic of cervical afferent involvement in headache. Thirty-four headache sufferers and 14 controls were examined interictally. Headache patients were diagnosed according the criteria of the International Headache Society and comprised 20 migraine without aura (females n = 18; males n = 2; average age 35.3 years) and 14 TTH sufferers (females n = 11; males n = 3; average age 30.7 years). Two techniques were used specifically to stress the atlantooccipital segments (Technique 1 - C1) and C2-3 zygapophysial joints (Technique 2 - C2). Two techniques were also applied to the arm--the common extensor origin and the mid belly of the biceps brachii. Participants reported reproduction of head pain with "yes" or "no" and rated the intensity of head pain and local pressure of application on a scale of 0 -10, where 0 = no pain and 10 = intolerable pain. None of the subjects reported head pain during application of techniques on the arm. Head pain referral during the

  3. The arms race control

    International Nuclear Information System (INIS)

    Nemo, J.

    2010-01-01

    Written in 1961, this paper presents the content of a book entitled 'The arms race control' where the author outlined the difference between disarmament and arms control, described the economic and moral role of arms race, the importance of force balance for international security. He wandered whether arms control could ensure this balance and whether nuclear balance meant force balance. Force balance then appears to be a precarious and unsteady component of international security. He commented the challenges of disarmament, recalled some arguments for a nuclear disarmament. Then he discussed what would be an arms control with or without disarmament (either nuclear or conventional)

  4. How do octopuses use their arms?

    Science.gov (United States)

    Mather, J A

    1998-09-01

    A taxonomy of the movement patterns of the 8 flexible arms of octopuses is constructed. Components consist of movements of the arm itself, the ventral suckers and their stalks, as well as the relative position of arms and the skin web between them. Within 1 arm, combinations of components result in a variety of behaviors. At the level of all arms, 1 group of behaviors is described as postures, on the basis of the spread of all arms and the web to make a 2-dimensional surface whose position differs in the 3rd dimension. Another group of arm behaviors is actions, more or less coordinated and involving several to all arms. Arm control appears to be based on radial symmetry, relative equipotentiality of all arms, relative independence of each arm, and separability of components within the arm. The types and coordination of arm behaviors are discussed with relationship to biomechanical limits, muscle structures, and neuronal programming.

  5. Classification of bones from MR images in torso PET-MR imaging using a statistical shape model

    International Nuclear Information System (INIS)

    Reza Ay, Mohammad; Akbarzadeh, Afshin; Ahmadian, Alireza; Zaidi, Habib

    2014-01-01

    There have been exclusive features for hybrid PET/MRI systems in comparison with its PET/CT counterpart in terms of reduction of radiation exposure, improved soft-tissue contrast and truly simultaneous and multi-parametric imaging capabilities. However, quantitative imaging on PET/MR is challenged by attenuation of annihilation photons through their pathway. The correction for photon attenuation requires the availability of patient-specific attenuation map, which accounts for the spatial distribution of attenuation coefficients of biological tissues. However, the lack of information on electron density in the MR signal poses an inherent difficulty to the derivation of the attenuation map from MR images. In other words, the MR signal correlates with proton densities and tissue relaxation properties, rather than with electron density and, as such, it is not directly related to attenuation coefficients. In order to derive the attenuation map from MR images at 511 keV, various strategies have been proposed and implemented on prototype and commercial PET/MR systems. Segmentation-based methods generate an attenuation map by classification of T1-weighted or high resolution Dixon MR sequences followed by assignment of predefined attenuation coefficients to various tissue types. Intensity-based segmentation approaches fail to include bones in the attenuation map since the segmentation of bones from conventional MR sequences is a difficult task. Most MR-guided attenuation correction techniques ignore bones owing to the inherent difficulties associated with bone segmentation unless specialized MR sequences such as ultra-short echo (UTE) sequence are utilized. In this work, we introduce a new technique based on statistical shape modeling to segment bones and generate a four-class attenuation map. Our segmentation approach requires a torso bone shape model based on principle component analysis (PCA). A CT-based training set including clearly segmented bones of the torso region

  6. Design and motion control of bioinspired humanoid robot head from servo motors toward artificial muscles

    Science.gov (United States)

    Almubarak, Yara; Tadesse, Yonas

    2017-04-01

    The potential applications of humanoid robots in social environments, motivates researchers to design, and control biomimetic humanoid robots. Generally, people are more interested to interact with robots that have similar attributes and movements to humans. The head is one of most important part of any social robot. Currently, most humanoid heads use electrical motors, pneumatic actuators, and shape memory alloy (SMA) actuators for actuation. Electrical and pneumatic actuators take most of the space and would cause unsmooth motions. SMAs are expensive to use in humanoids. Recently, in many robotic projects, Twisted and Coiled Polymer (TCP) artificial muscles are used as linear actuators which take up little space compared to the motors. In this paper, we will demonstrate the designing process and motion control of a robotic head with TCP muscles. Servo motors and artificial muscles are used for actuating the head motion, which have been controlled by a cost efficient ARM Cortex-M7 based development board. A complete comparison between the two actuators is presented.

  7. CyARM: Haptic Sensing Device for Spatial Localization on Basis of Exploration by Arms

    Directory of Open Access Journals (Sweden)

    Junichi Akita

    2009-01-01

    Full Text Available We introduce a new type of perception aid device based on user's exploration action, which is named as CyARM (acronym of “Cyber Arm”. The user holds this device in her/his arm, the extension of the arm is controlled by tension in wires, which are attached to her/his body according to the distance to the object. This user interface has unique characteristics that give users the illusion of an imaginary arm that extends to existing objects. The implementations of CyARM and our two experiments to investigate the efficiency and effectiveness of CyARM are described. The results show that we could confirm that CyARM can be used to recognize the presence of an object in front of the user and to measure the relative distance to the object.

  8. Characterizing occipital condyle loads under high-speed head rotation.

    Science.gov (United States)

    Pintar, Frank A; Yoganandan, Narayan; Baisden, Jamie

    2005-11-01

    Because of the need to evaluate anthropomorphic test device (ATD) biofidelity under high-head angular accelerations, the purpose of the present investigation was to develop appropriate instrumentation for intact post mortem human subject (PMHS) testing, validate the instrumentation, and obtain information to characterize the response of the head-neck complex under this loading scenario. A series of rigid-arm pendulum, inertially loaded ATD tests was conducted. Head and neck ATD hydraulic piston chin pull tests were conducted. Subsequently, a series of PMHS tests was conducted to derive the response of the human head-neck under high-rate chin loading. Finally, Hybrid III and THOR-NT ATD head-neck systems were evaluated under the same scenario as the PMHS. A parametric analysis for center of gravity (CG) location and accelerometer orientation determined that even small errors (+/- 3 mm or 2 degrees), produced errors in the force and moment calculations by as much as 17 %. If the moment of inertia (MOI) term was varied by 5 %, resulting moment calculations were affected by as much as 8 %. If the 5 % error in MOI was used to compute occipital condyle moments, and results compared to upper load cell derived moments, peaks differed by as much as 24 %. The head CG and mass MOI should be directly measured for each preparation to obtain accurate results. The injury run on each specimen resulted in predominantly C1-C2 separations or partial separations. The 50(th) percentile probability of AIS=2+ neck injury using tensile force was about 2400 N; for AIS=3+ neck injury the 50(th) percentile risk was about 3180 N. When inserting extension moment as the criteria, the 50(th) percentile probability of an AIS=2+ injury was 51 Nm. The AIS=3+ extension moment at the 50(th) percentile probability was 75 Nm. The new THOR-NT ATD head-neck produced more biofidelic responses with an alternate head-neck junction design compared to the Hybrid III ATD.

  9. In Situ Measurement of Seeking Speed and Seeking Induced Head-Disk Interface Instability in Hard Disk Drives

    Directory of Open Access Journals (Sweden)

    Yu Wang

    2015-01-01

    Full Text Available This paper investigated the instability of head-disk interface caused by the voice coil motor (VCM end crashing the crash stop during the seeking of magnetic head. To make the whole process of that clear, an in situ measurement method based on maximum likelihood estimation and extended Kalman filter for seeking speed at component level was developed first and was then calibrated by a high speed camera. Given a crash between VCM end and crash stop that may be a consequence of the continuous increasing seeking speed, the seeking speed was carefully controlled by using our developed method to find a critical value that may induce vigorous head-disk interface instability. Acoustic emission sensor and laser Doppler vibrometer were used to capture the transient dynamic behaviors of magnetic head when the crash is happening. Damage analysis and mode identification were carried out to reveal the relationship between the damage patterns on disk surface and head dynamics. The results of this study are helpful to optimize the track seeking profile during the HDD operation, as well as the design of components such as head and head arm.

  10. Traces across the body: influence of music-dance synchrony on the observation of dance.

    Science.gov (United States)

    Woolhouse, Matthew Harold; Lai, Rosemary

    2014-01-01

    In previous studies investigating entrainment and person perception, synchronized movements were found to enhance memory for incidental person attributes. Although this effect is robust, including in dance, the process by which it is actuated are less well understood. In this study, two hypotheses are investigated: that enhanced memory for person attributes is the result of (1) increased gaze time between in-tempo dancers; and/or (2) greater attentional focus between in-tempo dancers. To explore these possible mechanisms in the context of observing dance, an eye-tracking study was conducted in which subjects watched videos of pairs of laterally positioned dancers; only one of the dancers was synchronized with the music, the other being asynchronous. The results were consistent with the first hypothesis-music-dance synchrony gives rise to increased visual inspection times. In addition, there was a preference for upper-body fixations over lower-body fixations across both synchronous and asynchronous conditions. A subsequent, single-dancer eye-tracking study investigated fixations across different body regions, including head, torso, legs and feet. Significantly greater dwell times were recorded for head than torso and legs; feet attracted significantly less dwell time than any other body region. Lastly, the study sought to identify dance gestures responsible for torso- and head-directed fixations. Specifically we asked whether there are features in dance that are specially designed to direct an observer's gaze towards the face-the main "communicative portal" with respect to the transmission of intent, affect and empathy.

  11. Supervised Remote Robot with Guided Autonomy and Teleoperation (SURROGATE): A Framework for Whole-Body Manipulation

    Science.gov (United States)

    Hebert, Paul; Ma, Jeremy; Borders, James; Aydemir, Alper; Bajracharya, Max; Hudson, Nicolas; Shankar, Krishna; Karumanchi, Sisir; Douillard, Bertrand; Burdick, Joel

    2015-01-01

    The use of the cognitive capabilties of humans to help guide the autonomy of robotics platforms in what is typically called "supervised-autonomy" is becoming more commonplace in robotics research. The work discussed in this paper presents an approach to a human-in-the-loop mode of robot operation that integrates high level human cognition and commanding with the intelligence and processing power of autonomous systems. Our framework for a "Supervised Remote Robot with Guided Autonomy and Teleoperation" (SURROGATE) is demonstrated on a robotic platform consisting of a pan-tilt perception head, two 7-DOF arms connected by a single 7-DOF torso, mounted on a tracked-wheel base. We present an architecture that allows high-level supervisory commands and intents to be specified by a user that are then interpreted by the robotic system to perform whole body manipulation tasks autonomously. We use a concept of "behaviors" to chain together sequences of "actions" for the robot to perform which is then executed real time.

  12. A randomized study of accelerated fractionation radiotherapy with and without mitomycin C in the treatment of locally advanced head and neck cancer

    DEFF Research Database (Denmark)

    Ezzat, M.; Shouman, T.; Zaza, K.

    2005-01-01

    Objectives: This single-institution study evaluates the feasibility of accelerated fractionation radiotherapy (AF) with and without mitomycin C (MMC) in the treatment of locally advanced head and neck cancer. Patients and Methods: Between May 1998 and October 2001, sixty patients with locally...... advanced stage III and IV of head and neck cancer were randomized into three treatment arms: (1) conventional fractionation radiotherapy (CF) (5 fractions per week); (2) accelerated fractionation radiotherapy (AF) (6 fractions per week); and (3) AF plus Mitomycin C (MMC). Results: The 2-year overall....... Key Words: Head and Neck cancer , Radiotherapy , Altered fractionation , Mitomycin C....

  13. Quantitative Analysis of Torso FDG-PET Scans by Using Anatomical Standardization of Normal Cases from Thorough Physical Examinations.

    Directory of Open Access Journals (Sweden)

    Takeshi Hara

    Full Text Available Understanding of standardized uptake value (SUV of 2-deoxy-2-[18F]fluoro-d-glucose positron emission tomography (FDG-PET depends on the background accumulations of glucose because the SUV often varies the status of patients. The purpose of this study was to develop a new method for quantitative analysis of SUV of FDG-PET scan images. The method included an anatomical standardization and a statistical comparison with normal cases by using Z-score that are often used in SPM or 3D-SSP approach for brain function analysis. Our scheme consisted of two approaches, which included the construction of a normal model and the determination of the SUV scores as Z-score index for measuring the abnormality of an FDG-PET scan image. To construct the normal torso model, all of the normal images were registered into one shape, which indicated the normal range of SUV at all voxels. The image deformation process consisted of a whole body rigid registration of shoulder to bladder region and liver registration and a non-linear registration of body surface by using the thin-plate spline technique. In order to validate usefulness of our method, we segment suspicious regions on FDG-PET images manually, and obtained the Z-scores of the regions based on the corresponding voxels that stores the mean and the standard deviations from the normal model. We collected 243 (143 males and 100 females normal cases to construct the normal model. We also extracted 432 abnormal spots from 63 abnormal cases (73 cancer lesions to validate the Z-scores. The Z-scores of 417 out of 432 abnormal spots were higher than 2.0, which statistically indicated the severity of the spots. In conclusions, the Z-scores obtained by our computerized scheme with anatomical standardization of torso region would be useful for visualization and detection of subtle lesions on FDG-PET scan images even when the SUV may not clearly show an abnormality.

  14. Heading and head injuries in soccer.

    Science.gov (United States)

    Kirkendall, D T; Jordan, S E; Garrett, W E

    2001-01-01

    In the world of sports, soccer is unique because of the purposeful use of the unprotected head for controlling and advancing the ball. This skill obviously places the player at risk of head injury and the game does carry some risk. Head injury can be a result of contact of the head with another head (or other body parts), ground, goal post, other unknown objects or even the ball. Such impacts can lead to contusions, fractures, eye injuries, concussions or even, in rare cases, death. Coaches, players, parents and physicians are rightly concerned about the risk of head injury in soccer. Current research shows that selected soccer players have some degree of cognitive dysfunction. It is important to determine the reasons behind such deficits. Purposeful heading has been blamed, but a closer look at the studies that focus on heading has revealed methodological concerns that question the validity of blaming purposeful heading of the ball. The player's history and age (did they play when the ball was leather and could absorb significant amounts of water), alcohol intake, drug intake, learning disabilities, concussion definition and control group use/composition are all factors that cloud the ability to blame purposeful heading. What does seem clear is that a player's history of concussive episodes is a more likely explanation for cognitive deficits. While it is likely that the subconcussive impact of purposeful heading is a doubtful factor in the noted deficits, it is unknown whether multiple subconcussive impacts might have some lingering effects. In addition, it is unknown whether the noted deficits have any affect on daily life. Proper instruction in the technique is critical because if the ball contacts an unprepared head (as in accidental head-ball contacts), the potential for serious injury is possible. To further our understanding of the relationship of heading, head injury and cognitive deficits, we need to: learn more about the actual impact of a ball on the

  15. Armed conflict and child health.

    Science.gov (United States)

    Rieder, Michael; Choonara, Imti

    2012-01-01

    Armed conflict has a major impact on child health throughout the world. One in six children worldwide lives in an area of armed conflict and civilians are more likely to die than soldiers as a result of the conflict. In stark contrast to the effect on children, the international arms trade results in huge profits for the large corporations involved in producing arms, weapons and munitions. Armed conflict is not inevitable but is an important health issue that should be prevented.

  16. Hello to Arms

    Science.gov (United States)

    2005-01-01

    This image highlights the hidden spiral arms (blue) that were discovered around the nearby galaxy NGC 4625 by the ultraviolet eyes of NASA's Galaxy Evolution Explorer. The image is composed of ultraviolet and visible-light data, from the Galaxy Evolution Explorer and the California Institute of Technology's Digitized Sky Survey, respectively. Near-ultraviolet light is colored green; far-ultraviolet light is colored blue; and optical light is colored red. As the image demonstrates, the lengthy spiral arms are nearly invisible when viewed in optical light while bright in ultraviolet. This is because they are bustling with hot, newborn stars that radiate primarily ultraviolet light. The youthful arms are also very long, stretching out to a distance four times the size of the galaxy's core. They are part of the largest ultraviolet galactic disk discovered so far. Located 31 million light-years away in the constellation Canes Venatici, NGC 4625 is the closest galaxy ever seen with such a young halo of arms. It is slightly smaller than our Milky Way, both in size and mass. However, the fact that this galaxy's disk is forming stars very actively suggests that it might evolve into a more massive and mature galaxy resembling our own. The armless companion galaxy seen below NGC 4625 is called NGC 4618. Astronomers do not know why it lacks arms but speculate that it may have triggered the development of arms in NGC 4625.

  17. Prototipo de sistema de visión artificial en un vehículo aéreo no tripulado para la detección de órdenes gestuales

    OpenAIRE

    Bustillos Catota, Ana Belen; Farinango Defaz, Daniel Patricio

    2018-01-01

    The main objective of this degree project is to facilitate the navigation of the operator of an unmanned aerial vessel through a camera and using an artificial vision system will be able to recognize patterns made with the back and arm of a person fully identified. Using quadripopter Ar dron 2.0, a control system based on body gestures was developed that allows handling translation movements using artificial vision. The titling work allows to identify the gestures made with the torso and arm ...

  18. Visual Display of 5p-arm and 3p-arm miRNA Expression with a Mobile Application.

    Science.gov (United States)

    Pan, Chao-Yu; Kuo, Wei-Ting; Chiu, Chien-Yuan; Lin, Wen-Chang

    2017-01-01

    MicroRNAs (miRNAs) play important roles in human cancers. In previous studies, we have demonstrated that both 5p-arm and 3p-arm of mature miRNAs could be expressed from the same precursor and we further interrogated the 5p-arm and 3p-arm miRNA expression with a comprehensive arm feature annotation list. To assist biologists to visualize the differential 5p-arm and 3p-arm miRNA expression patterns, we utilized a user-friendly mobile App to display. The Cancer Genome Atlas (TCGA) miRNA-Seq expression information. We have collected over 4,500 miRNA-Seq datasets from 15 TCGA cancer types and further processed them with the 5p-arm and 3p-arm annotation analysis pipeline. In order to be displayed with the RNA-Seq Viewer App, annotated 5p-arm and 3p-arm miRNA expression information and miRNA gene loci information were converted into SQLite tables. In this distinct application, for any given miRNA gene, 5p-arm miRNA is illustrated on the top of chromosome ideogram and 3p-arm miRNA is illustrated on the bottom of chromosome ideogram. Users can then easily interrogate the differentially 5p-arm/3p-arm expressed miRNAs with their mobile devices. This study demonstrates the feasibility and utility of RNA-Seq Viewer App in addition to mRNA-Seq data visualization.

  19. Visual Display of 5p-arm and 3p-arm miRNA Expression with a Mobile Application

    Directory of Open Access Journals (Sweden)

    Chao-Yu Pan

    2017-01-01

    Full Text Available MicroRNAs (miRNAs play important roles in human cancers. In previous studies, we have demonstrated that both 5p-arm and 3p-arm of mature miRNAs could be expressed from the same precursor and we further interrogated the 5p-arm and 3p-arm miRNA expression with a comprehensive arm feature annotation list. To assist biologists to visualize the differential 5p-arm and 3p-arm miRNA expression patterns, we utilized a user-friendly mobile App to display. The Cancer Genome Atlas (TCGA miRNA-Seq expression information. We have collected over 4,500 miRNA-Seq datasets from 15 TCGA cancer types and further processed them with the 5p-arm and 3p-arm annotation analysis pipeline. In order to be displayed with the RNA-Seq Viewer App, annotated 5p-arm and 3p-arm miRNA expression information and miRNA gene loci information were converted into SQLite tables. In this distinct application, for any given miRNA gene, 5p-arm miRNA is illustrated on the top of chromosome ideogram and 3p-arm miRNA is illustrated on the bottom of chromosome ideogram. Users can then easily interrogate the differentially 5p-arm/3p-arm expressed miRNAs with their mobile devices. This study demonstrates the feasibility and utility of RNA-Seq Viewer App in addition to mRNA-Seq data visualization.

  20. Unequal-Arms Michelson Interferometers

    Science.gov (United States)

    Tinto, Massimo; Armstrong, J. W.

    2000-01-01

    Michelson interferometers allow phase measurements many orders of magnitude below the phase stability of the laser light injected into their two almost equal-length arms. If, however, the two arms are unequal, the laser fluctuations can not be removed by simply recombining the two beams. This is because the laser jitters experience different time delays in the two arms, and therefore can not cancel at the photo detector. We present here a method for achieving exact laser noise cancellation, even in an unequal-arm interferometer. The method presented in this paper requires a separate readout of the relative phase in each arm, made by interfering the returning beam in each arm with a fraction of the outgoing beam. By linearly combining the two data sets with themselves, after they have been properly time shifted, we show that it is possible to construct a new data set that is free of laser fluctuations. An application of this technique to future planned space-based laser interferometer detector3 of gravitational radiation is discussed.

  1. Armed conflict and child health

    OpenAIRE

    Rieder, Michael; Choonara, Imti

    2012-01-01

    Armed conflict has a major impact on child health\\ud throughout the world. One in six children worldwide lives\\ud in an area of armed conflict and civilians are more likely\\ud to die than soldiers as a result of the conflict. In stark\\ud contrast to the effect on children, the international arms\\ud trade results in huge profits for the large corporations\\ud involved in producing arms, weapons and munitions.\\ud Armed conflict is not inevitable but is an important\\ud health issue that should be...

  2. Injerto libre braquial medial Free medial arm graft

    Directory of Open Access Journals (Sweden)

    P. Martos Díaz

    2007-12-01

    Full Text Available Introducción. Entre las reconstrucciones de defectos titulares de cabeza y cuello, el injerto libre microvascularizado braquial medial no ha adquirido mucha popularidad debido a las variaciones anatómicas que se reflejan en la vascularización de éste. Nuestro objetivo es realizar una descripción de la anatomía y técnica quirúrgica, así como una revisión de la literatura describiendo las ventajas y desventajas de este tipo de injerto. Material y método. Presentamos el caso de una paciente con carcinoma epidermoide de mucosa yugal izquierda con afectación ganglionar ipsilateral. Se procedió a su resección con márgenes más disección cervical funcional. La reconstrucción del defecto se llevó a cabo mediante un injerto libre microvascularizado braquial medial de brazo izquierdo. Discusión. Pensamos que el injerto libre braquial medial de brazo se trata de una opción más segura a la hora de la reconstrucción de defectos cervicofaciales, aportando una serie de ventajas entre las que destacan: no sacrificio de una arteria terminal, cierre primario de la zona donante, mínimo defecto estético, y poseer una piel fina, elástica y sin vello.Introduction. Free medial microvascularized arm grafts have not become very popular for the reconstruction of head and neck defects due to anatomic variations in their vascularization. Our objective was to describe the anatomy and surgical technique and to review the literature on the advantages and disadvantages of free medial arm grafts. Material and methods. We report the case of a patient with squamous cell carcinoma of the left jugal mucosa with same-side lymph node involvement. The tumor was resected with margins and a functional cervical dissection was performed. The defect was reconstructed using a free medial microvascularized graft from the left arm. Discussion. We believe that free medial arm grafts are a safer option for the reconstruction of cervicofacial defects and that they offer

  3. Effects of age, sex and arm on the precision of arm position sense—left-arm superiority in healthy right-handers

    OpenAIRE

    Schmidt, Lena; Depper, Lena; Kerkhoff, Georg

    2013-01-01

    Position sense is an important proprioceptive ability. Disorders of arm position sense (APS) often occur after unilateral stroke, and are associated with a negative functional outcome. In the present study we assessed horizontal APS by measuring angular deviations from a visually defined target separately for each arm in a large group of healthy subjects. We analyzed the accuracy and instability of horizontal APS as a function of age, sex and arm. Subjects were required to specify verbally th...

  4. Performance of arm locking in LISA

    International Nuclear Information System (INIS)

    McKenzie, Kirk; Spero, Robert E.; Shaddock, Daniel A.

    2009-01-01

    For the Laser Interferometer Space Antenna (LISA) to reach its design sensitivity, the coupling of the free-running laser frequency noise to the signal readout must be reduced by more than 14 orders of magnitude. One technique employed to reduce the laser frequency noise will be arm locking, where the laser frequency is locked to the LISA arm length. In this paper we detail an implementation of arm locking. We investigate orbital effects (changing arm lengths and Doppler frequencies), the impact of errors in the Doppler knowledge that can cause pulling of the laser frequency, and the noise limit of arm locking. Laser frequency pulling is examined in two regimes: at lock acquisition and in steady state. The noise performance of arm locking is calculated with the inclusion of the dominant expected noise sources: ultrastable oscillator (clock) noise, spacecraft motion, and shot noise. We find that clock noise and spacecraft motion limit the performance of dual arm locking in the LISA science band. Studying these issues reveals that although dual arm locking [A. Sutton and D. A. Shaddock, Phys. Rev. D 78, 082001 (2008)] has advantages over single (or common) arm locking in terms of allowing high gain, it has disadvantages in both laser frequency pulling and noise performance. We address this by proposing a modification to the dual arm-locking sensor, a hybrid of common and dual arm-locking sensors. This modified dual arm-locking sensor has the laser frequency pulling characteristics and low-frequency noise coupling of common arm locking, but retains the control system advantages of dual arm locking. We present a detailed design of an arm-locking controller and perform an analysis of the expected performance when used with and without laser prestabilization. We observe that the sensor phase changes beneficially near unity-gain frequencies of the arm-locking controller, allowing a factor of 10 more gain than previously believed, without degrading stability. With a time

  5. Application of vibro-acoustical studies in process of improving dependability of arm-mounted cutter-heads of KGSA-320 shearers

    Energy Technology Data Exchange (ETDEWEB)

    Zakrzewski, T; Sikora, W

    1986-01-01

    Discusses application of acoustic vibration measurements in maintenance of mining machines. A formula is given for the dimensionless directional discriminant using which the technical state of shearer loader cutting heads can be assessed. KGS-320 shearer cutting drums were investigated at suitable points characterized by maximum deviations from zero reference values. Measurements were carried out in idle-run conditions and are given in graphs: distribution of changes in peak directivity coefficient deviation value for vibration displacement in relation to order number N of cutter head as well as location of measurement point; and distribution of changes in peak directivity coefficient deviation value for vibration velocity in relation to order number N of cutter head and location of the measurement point. An aim is to develop classification criteria for vibration acoustic diagnostics and to use the method for designing and manufacturing machines. 12 refs.

  6. Automated torso organ segmentation from 3D CT images using structured perceptron and dual decomposition

    Science.gov (United States)

    Nimura, Yukitaka; Hayashi, Yuichiro; Kitasaka, Takayuki; Mori, Kensaku

    2015-03-01

    This paper presents a method for torso organ segmentation from abdominal CT images using structured perceptron and dual decomposition. A lot of methods have been proposed to enable automated extraction of organ regions from volumetric medical images. However, it is necessary to adjust empirical parameters of them to obtain precise organ regions. This paper proposes an organ segmentation method using structured output learning. Our method utilizes a graphical model and binary features which represent the relationship between voxel intensities and organ labels. Also we optimize the weights of the graphical model by structured perceptron and estimate the best organ label for a given image by dynamic programming and dual decomposition. The experimental result revealed that the proposed method can extract organ regions automatically using structured output learning. The error of organ label estimation was 4.4%. The DICE coefficients of left lung, right lung, heart, liver, spleen, pancreas, left kidney, right kidney, and gallbladder were 0.91, 0.95, 0.77, 0.81, 0.74, 0.08, 0.83, 0.84, and 0.03, respectively.

  7. Design of a multi-arm randomized clinical trial with no control arm.

    Science.gov (United States)

    Magaret, Amalia; Angus, Derek C; Adhikari, Neill K J; Banura, Patrick; Kissoon, Niranjan; Lawler, James V; Jacob, Shevin T

    2016-01-01

    Clinical trial designs that include multiple treatments are currently limited to those that perform pairwise comparisons of each investigational treatment to a single control. However, there are settings, such as the recent Ebola outbreak, in which no treatment has been demonstrated to be effective; and therefore, no standard of care exists which would serve as an appropriate control. For illustrative purposes, we focused on the care of patients presenting in austere settings with critically ill 'sepsis-like' syndromes. Our approach involves a novel algorithm for comparing mortality among arms without requiring a single fixed control. The algorithm allows poorly-performing arms to be dropped during interim analyses. Consequently, the study may be completed earlier than planned. We used simulation to determine operating characteristics for the trial and to estimate the required sample size. We present a potential study design targeting a minimal effect size of a 23% relative reduction in mortality between any pair of arms. Using estimated power and spurious significance rates from the simulated scenarios, we show that such a trial would require 2550 participants. Over a range of scenarios, our study has 80 to 99% power to select the optimal treatment. Using a fixed control design, if the control arm is least efficacious, 640 subjects would be enrolled into the least efficacious arm, while our algorithm would enroll between 170 and 430. This simulation method can be easily extended to other settings or other binary outcomes. Early dropping of arms is efficient and ethical when conducting clinical trials with multiple arms. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. Complete rupture of the long head of the biceps tendon and the distal biceps tendon

    Directory of Open Access Journals (Sweden)

    Pieter J. Oberholzer

    2014-12-01

    Full Text Available The most common injury to the biceps muscle is rupture of the long head of the biceps tendon. A tear can occur proximally, distally or at the musculotendinous junction. Two cases are discussed, in both of which the patients felt a sudden sharp pain in the upper arm, at the shoulder and elbow respectively, and presented with a biceps muscle bump (Popeye deformity.

  9. Nonspecific Arm Pain

    Directory of Open Access Journals (Sweden)

    Ali Moradi

    2013-12-01

    Full Text Available Nonspecific activity-related arm pain is characterized by an absence of objective physical findings and symptoms that do not correspond with objective pathophysiology. Arm pain without strict diagnosis is often related to activity, work-related activity in particular, and is often seen in patients with physically demanding work. Psychological factors such as catastrophic thinking, symptoms of depression, and heightened illness concern determine a substantial percentage of the disability associated with puzzling hand and arm pains. Ergonomic modifications can help to control symptoms, but optimal health may require collaborative management incorporating psychosocial and psychological elements of illness.

  10. Nonspecific Arm Pain

    Directory of Open Access Journals (Sweden)

    Ali Moradi

    2013-12-01

    Full Text Available   Nonspecific activity-related arm pain is characterized by an absence of objective physical findings and symptoms that do not correspond with objective pathophysiology. Arm pain without strict diagnosis is often related to activity, work-related activity in particular, and is often seen in patients with physically demanding work. Psychological factors such as catastrophic thinking, symptoms of depression, and heightened illness concern determine a substantial percentage of the disability associated with puzzling hand and arm pains. Ergonomic modifications can help to control symptoms, but optimal health may require collaborative management incorporating psychosocial and psychological elements of illness.

  11. Effects of age, sex and arm on the precision of arm position sense-left-arm superiority in healthy right-handers.

    Science.gov (United States)

    Schmidt, Lena; Depper, Lena; Kerkhoff, Georg

    2013-01-01

    Position sense is an important proprioceptive ability. Disorders of arm position sense (APS) often occur after unilateral stroke, and are associated with a negative functional outcome. In the present study we assessed horizontal APS by measuring angular deviations from a visually defined target separately for each arm in a large group of healthy subjects. We analyzed the accuracy and instability of horizontal APS as a function of age, sex and arm. Subjects were required to specify verbally the position of their unseen arm on a 0-90° circuit by comparing the current position with the target position indicated by a LED lamp, while the arm was passively moved by the examiner. Eighty-seven healthy subjects participated in the study, ranging from 20 to 77 years, subdivided into three age groups. The results revealed that APS was not a function of age or sex, but was significantly better in the non-dominant (left) arm in absolute errors (AE) but not in constant errors (CE) across all age groups of right-handed healthy subjects. This indicates a right-hemisphere superiority for left APS in right-handers and neatly fits to the more frequent and more severe left-sided body-related deficits in patients with unilateral stroke (i.e. impaired APS in left spatial neglect, somatoparaphrenia) or in individuals with abnormalities of the right cerebral hemisphere. These clinical issues will be discussed.

  12. Arms control and disarmament

    International Nuclear Information System (INIS)

    Acton, P.

    1992-01-01

    Article VI of the Non-Proliferation Treaty commits each party to work towards nuclear disarmament and to negotiations to stop the nuclear arms race. All parties to the Treaty are included and a wide range of arms control and disarmament issues are covered. However the main focus at Treaty review conferences has been on nuclear disarmament by the nuclear weapon states which are party to the Treaty. This has led to bilateral United States - Soviet Union negotiations resulting in the Intermediate-range Nuclear Forces Treaty in December 1987 and the Strategic Arms Reduction Treaty (START) in July followed by unilateral arms control measures in September and October 1991. (UK)

  13. Henry Head and the Theatre of Reverie

    Directory of Open Access Journals (Sweden)

    Tiffany Watt-Smith

    2011-04-01

    Full Text Available In 1903, the neurologist Henry Head (1861-1940 embarked on a painful self-experiment, in which he severed the radial nerve of his left arm, and then charted the gradual and faltering return of sensitivity to the limb over the next four and a half years. To directly experience his own sensations, Head entered into a trance-like state of distraction or reverie he called a ‘negative attitude of attention’. This article explores Head’s peculiar technique for looking within, and argues that while introspection was an established strategy in psychological laboratories, Head’s reverie also resonated with techniques associated with actors and theatrical audiences during this period. Viewing psychological self-experimentation through the lens of theatre, this article makes visible aspects of Head’s embodied, affective laboratory encounters, often obscured in accounts of his experiment. At the same time, it proposes that the broader historical and cultural significance of Head’s experiment lies in his attempt to observe himself by producing states of inattention and reverie at will, mental ‘attitudes’ that were themselves the subject of a rapidly evolving debate in scientific and aesthetic circles at the turn of the twentieth century.

  14. Dynamics of socioeconomic risk factors for neglected tropical diseases and malaria in an armed conflict.

    Directory of Open Access Journals (Sweden)

    Thomas Fürst

    Full Text Available BACKGROUND: Armed conflict and war are among the leading causes of disability and premature death, and there is a growing share of civilians killed or injured during armed conflicts. A major part of the civilian suffering stems from indirect effects or collateral impact such as changing risk profiles for infectious diseases. We focused on rural communities in the western part of Côte d'Ivoire, where fighting took place during the Ivorian civil war in 2002/2003, and assessed the dynamics of socioeconomic risk factors for neglected tropical diseases (NTDs and malaria. METHODOLOGY: The same standardized and pre-tested questionnaires were administered to the heads of 182 randomly selected households in 25 villages in the region of Man, western Côte d'Ivoire, shortly before and after the 2002/2003 armed conflict. PRINCIPAL FINDINGS: There was no difference in crowding as measured by the number of individuals per sleeping room, but the inadequate sanitation infrastructure prior to the conflict further worsened, and the availability and use of protective measures against mosquito bites and accessibility to health care infrastructure deteriorated. Although the direct causal chain between these findings and the conflict are incomplete, partially explained by the very nature of working in conflict areas, the timing and procedures of the survey, other sources and anecdotal evidence point toward a relationship between an increased risk of suffering from NTDs and malaria and armed conflict. CONCLUSION: New research is needed to deepen our understanding of the often diffuse and neglected indirect effects of armed conflict and war, which may be worse than the more obvious, direct effects.

  15. A dual-Kinect approach to determine torso surface motion for respiratory motion correction in PET

    International Nuclear Information System (INIS)

    Heß, Mirco; Büther, Florian; Dawood, Mohammad; Schäfers, Klaus P.; Gigengack, Fabian

    2015-01-01

    Purpose: Respiratory gating is commonly used to reduce blurring effects and attenuation correction artifacts in positron emission tomography (PET). Established clinically available methods that employ body-attached hardware for acquiring respiration signals rely on the assumption that external surface motion and internal organ motion are well correlated. In this paper, the authors present a markerless method comprising two Microsoft Kinects for determining the motion on the whole torso surface and aim to demonstrate its validity and usefulness—including the potential to study the external/internal correlation and to provide useful information for more advanced correction approaches. Methods: The data of two Kinects are used to calculate 3D representations of a patient’s torso surface with high spatial coverage. Motion signals can be obtained for any position by tracking the mean distance to a virtual camera with a view perpendicular to the surrounding surface. The authors have conducted validation experiments including volunteers and a moving high-precision platform to verify the method’s suitability for providing meaningful data. In addition, the authors employed it during clinical 18 F-FDG-PET scans and exemplarily analyzed the acquired data of ten cancer patients. External signals of abdominal and thoracic regions as well as data-driven signals were used for gating and compared with respect to detected displacement of present lesions. Additionally, the authors quantified signal similarities and time shifts by analyzing cross-correlation sequences. Results: The authors’ results suggest a Kinect depth resolution of approximately 1 mm at 75 cm distance. Accordingly, valid signals could be obtained for surface movements with small amplitudes in the range of only few millimeters. In this small sample of ten patients, the abdominal signals were better suited for gating the PET data than the thoracic signals and the correlation of data-driven signals was found

  16. A dual-Kinect approach to determine torso surface motion for respiratory motion correction in PET

    Energy Technology Data Exchange (ETDEWEB)

    Heß, Mirco, E-mail: mirco.hess@uni-muenster.de; Büther, Florian; Dawood, Mohammad; Schäfers, Klaus P. [European Institute for Molecular Imaging, University of Münster, Münster 48149 (Germany); Gigengack, Fabian [European Institute for Molecular Imaging, University of Münster, Münster 48149, Germany and Department of Mathematics and Computer Science, University of Münster, Münster 48149 (Germany)

    2015-05-15

    Purpose: Respiratory gating is commonly used to reduce blurring effects and attenuation correction artifacts in positron emission tomography (PET). Established clinically available methods that employ body-attached hardware for acquiring respiration signals rely on the assumption that external surface motion and internal organ motion are well correlated. In this paper, the authors present a markerless method comprising two Microsoft Kinects for determining the motion on the whole torso surface and aim to demonstrate its validity and usefulness—including the potential to study the external/internal correlation and to provide useful information for more advanced correction approaches. Methods: The data of two Kinects are used to calculate 3D representations of a patient’s torso surface with high spatial coverage. Motion signals can be obtained for any position by tracking the mean distance to a virtual camera with a view perpendicular to the surrounding surface. The authors have conducted validation experiments including volunteers and a moving high-precision platform to verify the method’s suitability for providing meaningful data. In addition, the authors employed it during clinical {sup 18}F-FDG-PET scans and exemplarily analyzed the acquired data of ten cancer patients. External signals of abdominal and thoracic regions as well as data-driven signals were used for gating and compared with respect to detected displacement of present lesions. Additionally, the authors quantified signal similarities and time shifts by analyzing cross-correlation sequences. Results: The authors’ results suggest a Kinect depth resolution of approximately 1 mm at 75 cm distance. Accordingly, valid signals could be obtained for surface movements with small amplitudes in the range of only few millimeters. In this small sample of ten patients, the abdominal signals were better suited for gating the PET data than the thoracic signals and the correlation of data-driven signals was

  17. An EGS4-ready tomographic computational model of a 14-year-old female torso for calculating organ doses from CT examinations

    International Nuclear Information System (INIS)

    Caon, M.; School of Physics and Electronic Systems Engineering, University of South Australia, The Levels Campus, Mawson Lakes, South Australia, 5095; Pattison, J.

    1999-01-01

    Fifty-four consecutive CT scans have been used to construct a tomographic computational model of a 14-year-old female torso suitable for the determination of organ doses from CT. The model, known as ADELAIDE, is in the form of an input file compatible with user codes based on XYZDOS.MOR from the readily available EGS4 Monte Carlo radiation transport code. ADELAIDE's dimensions are close to the Australian averages for her age so the model is representative of a 14-year-old girl. The realistic anatomy in the model differs considerably from that in Cristy's 15-year-old mathematical computational model by having realistically shaped organs that are appropriately located within a real external contour. Average absorbed dose to organs from simulated CT examinations of the chest and abdomen have been calculated for ADELAIDE using EGS4 within a geometry specific to the General Electric Hi-Speed Advantage CT scanner and using an x-ray spectrum calculated using data from the scanner's x-ray tube. The simulations include the scanner's beam shaping filter and patient table. It is suggested that the resulting values have fewer possible sources of uncertainty than organ doses derived from dose coefficients calculated for a MIRD style model with mathematical anatomy and a spectrum that may not match that of the scanner. The organ doses were normalized using the scanner's CTDI measured free-in-air and an EGS4 simulation of the CTDI measurement. Effective dose to the torso from 26-slice chest and 24-slice abdomen examinations (at 120 kV, 200 mAs, 7 mm slices) is 4.6±0.1mSv and 4.3±0.1mSv respectively. (author)

  18. Understanding the conventional arms trade

    Science.gov (United States)

    Stohl, Rachel

    2017-11-01

    The global conventional arms trade is worth tens of billions of dollars every year and is engaged in by every country in the world. Yet, it is often difficult to control the legal trade in conventional arms and there is a thriving illicit market, willing to arm unscrupulous regimes and nefarious non-state actors. This chapter examines the international conventional arms trade, the range of tools that have been used to control it, and challenges to these international regimes.

  19. Traces Across the Body: The Influence of Music-Dance Synchrony on the Observation of Dance

    Directory of Open Access Journals (Sweden)

    Matthew Harold Woolhouse

    2014-12-01

    Full Text Available In previous studies investigating entrainment and person perception, synchronized movements were found to enhance memory for incidental person attributes. Although this effect is robust, including in dance, the process by which it is actuated are less well understood. In this study, two hypotheses are investigated: that enhanced memory for person attributes is the result of (1 increased gaze time between in-tempo dancers, and/or (2 greater attentional focus between in-tempo dancers. To explore these possible mechanisms in the context of observing dance, an eye-tracking study was conducted in which subjects watched videos of pairs of laterally positioned dancers; only one of the dancers was synchronized with the music, the other being asynchronous. The results were consistent with the first hypothesis—music-dance synchrony gives rise to increased visual inspection times. In addition, there was a preference for upper-body fixations over lower-body fixations across both synchronous and asynchronous conditions. A subsequent, single-dancer eye-tracking study investigated fixations across different body regions, including head, torso, legs and feet. Significantly greater dwell times were recorded for head than torso and legs; feet attracted significantly less dwell time than any other body region. Lastly, the study sought to identify dance gestures responsible for torso- and head-directed fixations. Specifically we asked whether there are features in dance that are specially designed to direct an observer’s gaze towards the face—the main communicative portal with respect to the transmission of intent, affect and empathy.

  20. Traces across the body: influence of music-dance synchrony on the observation of dance

    Science.gov (United States)

    Woolhouse, Matthew Harold; Lai, Rosemary

    2014-01-01

    In previous studies investigating entrainment and person perception, synchronized movements were found to enhance memory for incidental person attributes. Although this effect is robust, including in dance, the process by which it is actuated are less well understood. In this study, two hypotheses are investigated: that enhanced memory for person attributes is the result of (1) increased gaze time between in-tempo dancers; and/or (2) greater attentional focus between in-tempo dancers. To explore these possible mechanisms in the context of observing dance, an eye-tracking study was conducted in which subjects watched videos of pairs of laterally positioned dancers; only one of the dancers was synchronized with the music, the other being asynchronous. The results were consistent with the first hypothesis—music-dance synchrony gives rise to increased visual inspection times. In addition, there was a preference for upper-body fixations over lower-body fixations across both synchronous and asynchronous conditions. A subsequent, single-dancer eye-tracking study investigated fixations across different body regions, including head, torso, legs and feet. Significantly greater dwell times were recorded for head than torso and legs; feet attracted significantly less dwell time than any other body region. Lastly, the study sought to identify dance gestures responsible for torso- and head-directed fixations. Specifically we asked whether there are features in dance that are specially designed to direct an observer’s gaze towards the face—the main “communicative portal” with respect to the transmission of intent, affect and empathy. PMID:25520641

  1. Environmental effects monitoring at Cat Arm Hydraulic Development, Newfoundland, Canada

    International Nuclear Information System (INIS)

    Hill, E.L.

    1988-01-01

    The Cat Arm Dam is located on a plateau of the Long Range Mountains on Newfoundland's Great Northern Peninsula, and the 127 MW unit uses a 387 m head to produce an average of 676 GWh annually. Newfoundland and Labrador Hydro is conducting an environmental effects monitoring program in Cat Arm Reservoir to evaluate environmental impacts of the project. In the addendum to the Environmental Impact Statement of 1981, the utility agreed to a number of actions to mitigate the impacts of construction on fish populations, and to monitor the effects of reservoir creation, including the following. The mercury content of fish flesh, sediments and water would be monitored, and sampling would be undertaken prior to flooding to obtain baseline data, and for at least five years after flooding. The brook trout population would be monitored at various stages in the life of the reservoir in order to detect negative changes for which mitigative strategies could be applied. Alternative spawning habitat would be provided by removing barriers on streams or creating spawning beds if the monitoring program showed that recruitment was falling, and if these methods were ineffective, a compensatory stocking program would be considered. Extensive monitoring would be undertaken of the littoral zones, primary production in the reservoir, and of a number of limnological parameters to document long term changes in the reservoir. Although of academic interest, certain unusual characteristics of the Cat Arm reservoir, such as its low pH and dark colour, reduce its utility as a predictor of changes due to reservoir formation elsewhere in Newfoundland. 15 refs., 1 fig

  2. Student measurement of blood pressure using a simulator arm compared with a live subject's arm.

    Science.gov (United States)

    Lee, Jennifer J; Sobieraj, Diana M; Kuti, Effie L

    2010-06-15

    To compare accuracy of blood pressure measurements using a live subject and a simulator arm, and to determine students' preferences regarding measurement. This was a crossover study comparing blood pressure measurements from a live subject and a simulator arm. Students completed an anonymous survey instrument defining opinions on ease of measurement. Fifty-seven students completed blood pressure measurements on live subjects while 72 students completed blood pressure measurements using the simulator arm. There were no significant systematic differences between the 2 measurement techniques. Systolic blood pressure measurements from a live subject arm were less likely to be within 4 mm Hg compared with measurements of a simulator arm. Diastolic blood pressure measurements were not significantly different between the 2 techniques. Accuracy of student measurement of blood pressure using a simulator arm was similar to the accuracy with a live subject. There was no difference in students' preferences regarding measurement techniques.

  3. Borehole tool outrigger arm displacement control mechanism

    International Nuclear Information System (INIS)

    Lee, A.G.

    1985-01-01

    As the outrigger arms of a borehole logging tool are flexed inwardly and outwardly according to the diameter of the borehole opening through which they pass, the corresponding axial displacements of the ends of the arms are controlled to determine the axial positions of the arms relative to the tool. Specifically, as the arm ends move, they are caused to rotate by a cam mechanism. The stiffness of the arms causes the arm ends to rotate in unison, and the exact positions of the arms on the tool are then controlled by the differential movements of the arm ends in the cams

  4. Nonparetic arm force does not overinhibit the paretic arm in chronic poststroke hemiparesis.

    Science.gov (United States)

    Dimyan, Michael A; Perez, Monica A; Auh, Sungyoung; Tarula, Erick; Wilson, Matthew; Cohen, Leonardo G

    2014-05-01

    To determine whether nonparetic arm force overinhibits the paretic arm in patients with chronic unilateral poststroke hemiparesis. Case-control neurophysiological and behavioral study of patients with chronic stroke. Research institution. Eighty-six referred patients were screened to enroll 9 participants (N=9) with a >6 month history of 1 unilateral ischemic infarct that resulted in arm hemiparesis with residual ability to produce 1Nm of wrist flexion torque and without contraindication to transcranial magnetic stimulation. Eight age- and handedness-matched healthy volunteers without neurologic diagnosis were studied for comparison. Not applicable. Change in interhemispheric inhibition targeting the ipsilesional primary motor cortex (M1) during nonparetic arm force. We hypothesized that interhemispheric inhibition would increase more in healthy controls than in patients with hemiparesis. Healthy age-matched controls had significantly greater increases in inhibition from their active to resting M1 than patients with stroke from their active contralesional to resting ipsilesional M1 in the same scenario (20%±7% vs -1%±4%, F1,12=6.61, P=.025). Patients with greater increases in contralesional to ipsilesional inhibition were better performers on the 9-hole peg test of paretic arm function. Our findings reveal that producing force with the nonparetic arm does not necessarily overinhibit the paretic arm. Though our study is limited in generalizability by the small sample size, we found that greater active contralesional to resting ipsilesional M1 inhibition was related with better recovery in this subset of patients with chronic poststroke. Copyright © 2014 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  5. Labyrinth and cerebral-spinal fluid pressure changes in guinea pigs and monkeys during simulated zero G

    Science.gov (United States)

    Parker, D. E.

    1977-01-01

    This study was undertaken to explore the hypothesis that shifts of body fluids from the legs and torso toward the head contribute to the motion sickness experienced by astronauts and cosmonauts. The shifts in body fluids observed during zero-G exposure were simulated by elevating guinea pigs' and monkeys' torsos and hindquarters. Cerebral-spinal fluid pressure was recorded from a transducer located in a brain ventricle; labyrinth fluid pressure was recorded from a pipette cemented in a hole in a semicircular canal. An anticipated divergence in cerebral-spinal fluid pressure and labyrinth fluid pressure during torso elevation was not observed. The results of this study do not support a fluid shift mechanism of zero-G-induced motion sickness. However, a more complete test of the fluid shift mechanism would be obtained if endolymph and perilymph pressure changes were determined separately; we have been unable to perform this test to date.

  6. Gluteus medius kinesio-taping: the effect on torso-pelvic separation ...

    African Journals Online (AJOL)

    1 Physiotherapy Department, Faculty of Health Sciences, University of the. Witwatersrand ... accomplish this, the club head should be travelling at maximum speed at the .... analysed using a paired Student's t-test, when testing at the 0.05 level.

  7. Nature of galaxy spiral arms

    International Nuclear Information System (INIS)

    Efremov, Yu.N.

    1984-01-01

    The nature of galaxy spiral arms is discussed in a popular form. Two approaches in the theory of spiral arms are considered; they are related to the problem of differential galaxy rotation and the spiral structure wave theory. The example of Galaxy M31 is considered to compare the structural peculiarity of its spiral arms with the wave theory predictions. The situation in the central and south-eastern part of arm S4 in Galaxy M31 noted to be completely explained by the wave theory and modern concepts on the origin of massive stars

  8. Arms races between and within species.

    Science.gov (United States)

    Dawkins, R; Krebs, J R

    1979-09-21

    An adaptation in one lineage (e.g. predators) may change the selection pressure on another lineage (e.g. prey), giving rise to a counter-adaptation. If this occurs reciprocally, an unstable runaway escalation or 'arms race' may result. We discuss various factors which might give one side an advantage in an arms race. For example, a lineage under strong selection may out-evolve a weakly selected one (' the life-dinner principle'). We then classify arms races in two independent ways. They may be symmetric or asymmetric, and they may be interspecific or intraspecific. Our example of an asymmetric interspecific arms race is that between brood parasites and their hosts. The arms race concept may help to reduce the mystery of why cuckoo hosts are so good at detecting cuckoo eggs, but so bad at detecting cuckoo nestlings. The evolutionary contest between queen and worker ants over relative parental investment is a good example of an intraspecific asymmetric arms race. Such cases raise special problems because the participants share the same gene pool. Interspecific symmetric arms races are unlikely to be important, because competitors tend to diverge rather than escalate competitive adaptations. Intraspecific symmetric arms races, exemplified by adaptations for male-male competition, may underlie Cope's Rule and even the extinction of lineages. Finally we consider ways in which arms races can end. One lineage may drive the other to extinction; one may reach an optimum, thereby preventing the other from doing so; a particularly interesting possibility, exemplified by flower-bee coevolution, is that both sides may reach a mutual local optimum; lastly, arms races may have no stable and but may cycle continuously. We do not wish necessarily to suggest that all, or even most, evolutionary change results from arms races, but we do suggest that the arms race concept may help to resolve three long-standing questions in evolutionary theory.

  9. Development of automated ultrasonic device for in-service inspection of ABWR pressure vessel bottom head

    International Nuclear Information System (INIS)

    Kojima, Y.; Matsuyama, A.

    1995-01-01

    An automated device and its controller have been developed for the bottom head weld examination of pressure vessel of Advanced Boiling Water Reactor (ABWR). The internal pump casings and the housings of control rod prevent a conventional ultrasonic device from scanning the required inspection zone. With this reason, it is required to develop a new device to examine the bottom head area of ABWR. The developed device is characterized by the following features. (1) Composed of a mother vehicle and a compact inspection vehicle. They are connected only by an electric wire without using the conventional arm mechanism. (2) The mother vehicle travels on a track and lift up the inspection vehicle to the vessel. (3) The mother vehicle can automatically attach the inspection vehicle to the bottom head, and detach the inspection vehicle from it. (4) Collision avoidance control function with a touch sensor is installed at the front of the inspection vehicle. The device was successfully demonstrated using a mock-up of reactor pressure vessel

  10. JPRS Report Arms Control

    National Research Council Canada - National Science Library

    1993-01-01

    Table of Contents: (1) COMMONWEALTH OF INDEPENDENT STATES - (A) GENERAL Flaws in U.S.-Russian SSD Agreement Viewed, Khariton - Espionage Not Crucial in Soviet Nuclear Arms Development, Further on Espionage Role in Nuclear Arms Projects...

  11. Organization of octopus arm movements: a model system for studying the control of flexible arms.

    Science.gov (United States)

    Gutfreund, Y; Flash, T; Yarom, Y; Fiorito, G; Segev, I; Hochner, B

    1996-11-15

    Octopus arm movements provide an extreme example of controlled movements of a flexible arm with virtually unlimited degrees of freedom. This study aims to identify general principles in the organization of these movements. Video records of the movements of Octopus vulgaris performing the task of reaching toward a target were studied. The octopus extends its arm toward the target by a wave-like propagation of a bend that travels from the base of the arm toward the tip. Similar bend propagation is seen in other octopus arm movements, such as locomotion and searching. The kinematics (position and velocity) of the midpoint of the bend in three-dimensional space were extracted using the direct linear transformation algorithm. This showed that the bend tends to move within a single linear plane in a simple, slightly curved path connecting the center of the animal's body with the target location. Approximately 70% of the reaching movements demonstrated a stereotyped tangential velocity profile. An invariant profile was observed when movements were normalized for velocity and distance. Two arms, extended together in the same behavioral context, demonstrated identical velocity profiles. The stereotyped features of the movements were also observed in spontaneous arm extensions (not toward an external target). The simple and stereotypic appearance of the bend trajectory suggests that the position of the bend in space and time is the controlled variable. We propose that this strategy reduces the immense redundancy of the octopus arm movements and hence simplifies motor control.

  12. High precision detector robot arm system

    Science.gov (United States)

    Shu, Deming; Chu, Yong

    2017-01-31

    A method and high precision robot arm system are provided, for example, for X-ray nanodiffraction with an X-ray nanoprobe. The robot arm system includes duo-vertical-stages and a kinematic linkage system. A two-dimensional (2D) vertical plane ultra-precision robot arm supporting an X-ray detector provides positioning and manipulating of the X-ray detector. A vertical support for the 2D vertical plane robot arm includes spaced apart rails respectively engaging a first bearing structure and a second bearing structure carried by the 2D vertical plane robot arm.

  13. Algorithms for Unequal-Arm Michelson Interferometers

    Science.gov (United States)

    Giampieri, Giacomo; Hellings, Ronald W.; Tinto, Massimo; Bender, Peter L.; Faller, James E.

    1994-01-01

    A method of data acquisition and data analysis is described in which the performance of Michelson-type interferometers with unequal arms can be made nearly the same as interferometers with equal arms. The method requires a separate readout of the relative phase in each arm, made by interfering the returning beam in each arm with a fraction of the outgoing beam.

  14. FY1995 development of artificial arm 'SMART ARM' by spherical ultrasonic motor; 1995 nendo kyumen choonpa motor wo mochiita jinko gishu smart arm no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    The project has an intention of development of new type artificial arm by spherical ultrasonic motor. We have succeeded in developing new type of spherical ultrasonic motor with three DOF. And we have succeeded in applying the motor to an artificial arm. This arm have advantages of small size, low weight torque comparing with conventional ones. We demonstrated them the new arm behaved well and it had good controlabilty. (NEDO)

  15. Comparison of binaural microphones for externalization of sounds

    DEFF Research Database (Denmark)

    Cubick, Jens; Sánchez Rodríguez, C.; Song, Wookeun

    2015-01-01

    or with microphones placed inside the ear canals of a person. In this study, binaural room impulse responses (BRIRs) were measured with several commercially available binaural microphones, both placed inside the listeners’ ears (individual BRIR) and on a head and torso simulator (generic BRIR). The degree...

  16. Octopus-inspired multi-arm robotic swimming.

    Science.gov (United States)

    Sfakiotakis, M; Kazakidi, A; Tsakiris, D P

    2015-05-13

    The outstanding locomotor and manipulation characteristics of the octopus have recently inspired the development, by our group, of multi-functional robotic swimmers, featuring both manipulation and locomotion capabilities, which could be of significant engineering interest in underwater applications. During its little-studied arm-swimming behavior, as opposed to the better known jetting via the siphon, the animal appears to generate considerable propulsive thrust and rapid acceleration, predominantly employing movements of its arms. In this work, we capture the fundamental characteristics of the corresponding complex pattern of arm motion by a sculling profile, involving a fast power stroke and a slow recovery stroke. We investigate the propulsive capabilities of a multi-arm robotic system under various swimming gaits, namely patterns of arm coordination, which achieve the generation of forward, as well as backward, propulsion and turning. A lumped-element model of the robotic swimmer, which considers arm compliance and the interaction with the aquatic environment, was used to study the characteristics of these gaits, the effect of various kinematic parameters on propulsion, and the generation of complex trajectories. This investigation focuses on relatively high-stiffness arms. Experiments employing a compliant-body robotic prototype swimmer with eight compliant arms, all made of polyurethane, inside a water tank, successfully demonstrated this novel mode of underwater propulsion. Speeds of up to 0.26 body lengths per second (approximately 100 mm s(-1)), and propulsive forces of up to 3.5 N were achieved, with a non-dimensional cost of transport of 1.42 with all eight arms and of 0.9 with only two active arms. The experiments confirmed the computational results and verified the multi-arm maneuverability and simultaneous object grasping capability of such systems.

  17. Cachexia at diagnosis is associated with poor survival in head and neck cancer patients.

    Science.gov (United States)

    Orell-Kotikangas, Helena; Österlund, Pia; Mäkitie, Outi; Saarilahti, Kauko; Ravasco, Paula; Schwab, Ursula; Mäkitie, Antti A

    2017-07-01

    One third of the patients had cachexia with an association of significantly shorter survival. These results suggest that combining HGS and MAMA seems to be a practical method to screen cachexia in patients with head and neck cancer and may also be used when assessing their prognosis. The aim of this study was to analyze the hypothesis that cachexia defined as both low mid-arm muscle area (MAMA) and handgrip strength (HGS) is associated with decreased survival in patients with head and neck squamous cell carcinoma (HNSCC). Sixty-five consecutive patients with primary HNSCC were enrolled prior to cancer therapy. Cachexia was defined as low handgrip strength (HGS) and low mid-arm muscle area (MAMA). Nutritional status was assessed by patient-generated subjective global assessment (PG-SGA) and sarcopenia by low MAMA. Biochemical parameters reflecting nutritional status and S-25-OHD were measured. Cachexia was seen in 31% and sarcopenia in 46% of patients. Altogether, 34% of patients were malnourished. Disease-free survival was 13 months (3-62) in cachectic patients, compared with 66 months (31-78) in non-cachectic patients (p = 0.009). S-25-OHD was 28 nmol/l in cachectic patients, compared with 46 nmol/l in non-cachectic patients (p = 0.009) and prealbumin 187 mg/l and 269 mg/l, respectively (p < 0.001).

  18. Heads Up

    Science.gov (United States)

    ... Connect with Us HEADS UP Apps Reshaping the Culture Around Concussion in Sports Get HEADS UP on Your Web Site Concussion ... HEADS UP on your web site! Create a culture of safety for young athletes Officials, learn how you can ... UP to Providers HEADS UP to Youth Sports HEADS UP to School Sports HEADS UP to ...

  19. Results of an RTOG phase III trial (RTOG 85-27) comparing radiotherapy plus etanidazole with radiotherapy alone for locally advanced head and neck carcinomas

    Energy Technology Data Exchange (ETDEWEB)

    Dingjen, Lee; Cosmatos, Dennis; Marcial, Victor A; Fu, Karen K; Rotman, Marvin; Cooper, Jay S; Ortiz, Hernando G; Beitler, Jonathan J; Abrams, Ross A; Curran, Walter J; Coleman, C Norman; Wasserman, Todd H

    1995-06-15

    Purpose: The objectives of this study were to determine the efficacy and toxicity of Etanidazole (ETA), a hypoxic cell sensitizer, when combined with conventional radiotherapy (RT) in the management of advanced head and neck carcinomas. Methods and Materials: From March 1988 to September 1991, 521 patients who had Stage III or IV head and neck carcinomas were randomized to receive conventional RT alone (66 Gy in 33 fractions to 74 Gy in 37 fractions, 5 fractions per week) or RT + ETA (2.0 g/m{sup 2} thrice weekly for 17 doses), of whom 504 were eligible and analyzable. Treatment assignments were stratified before randomization according to the primary site (oral cavity + hypopharynx vs. supraglottic larynx + oropharynx + nasopharynx), T-stage (T1-3 vs. T4), and N-stage (N0-2 vs. N3). Pretreatment characteristics were balanced. In the RT-alone arm, 39% of patients had T3 and 34% had T4 disease, whereas in the RT + ETA arm, 42% of patients had T3 and 33% had T4 disease. Thirty-eight percent of the RT-alone patients and 37% of the RT + ETA patients had N3 disease. The median follow-up of surviving patients was 3.38 years, with a range between 0.96 and 5.63 years. Results: One hundred and ninety-four of the 252 (77%) RT + ETA patients received at least 14 doses of the drug. Overall RT protocol compliance rate was 82% in the RT-alone arm and 86% in the RT + ETA arm. No Grade 3 or 4 central nervous system or peripheral neuropathy was observed in the RT + ETA arm. Eighteen percent of the patients developed Grade 1 and 5% developed Grade 2 peripheral neuropathy. Other drug related toxicities included nausea/vomiting (27%), low blood counts (15%), and allergy (9%). Most of these toxicities were Grade 1 and 2. The incidence of severe acute and late radiation effects were similar between the two arms. The 2-year actuarial local-regional control rate (LCR) was 40% for the RT-alone arm and 40% for the RT + ETA arm. Two-year actuarial survival was 41% for the RT-alone arm and 43

  20. Results of an RTOG phase III trial (RTOG 85-27) comparing radiotherapy plus etanidazole with radiotherapy alone for locally advanced head and neck carcinomas

    International Nuclear Information System (INIS)

    Lee Dingjen; Cosmatos, Dennis; Marcial, Victor A.; Fu, Karen K.; Rotman, Marvin; Cooper, Jay S.; Ortiz, Hernando G.; Beitler, Jonathan J.; Abrams, Ross A.; Curran, Walter J.; Coleman, C. Norman; Wasserman, Todd H.

    1995-01-01

    Purpose: The objectives of this study were to determine the efficacy and toxicity of Etanidazole (ETA), a hypoxic cell sensitizer, when combined with conventional radiotherapy (RT) in the management of advanced head and neck carcinomas. Methods and Materials: From March 1988 to September 1991, 521 patients who had Stage III or IV head and neck carcinomas were randomized to receive conventional RT alone (66 Gy in 33 fractions to 74 Gy in 37 fractions, 5 fractions per week) or RT + ETA (2.0 g/m 2 thrice weekly for 17 doses), of whom 504 were eligible and analyzable. Treatment assignments were stratified before randomization according to the primary site (oral cavity + hypopharynx vs. supraglottic larynx + oropharynx + nasopharynx), T-stage (T1-3 vs. T4), and N-stage (N0-2 vs. N3). Pretreatment characteristics were balanced. In the RT-alone arm, 39% of patients had T3 and 34% had T4 disease, whereas in the RT + ETA arm, 42% of patients had T3 and 33% had T4 disease. Thirty-eight percent of the RT-alone patients and 37% of the RT + ETA patients had N3 disease. The median follow-up of surviving patients was 3.38 years, with a range between 0.96 and 5.63 years. Results: One hundred and ninety-four of the 252 (77%) RT + ETA patients received at least 14 doses of the drug. Overall RT protocol compliance rate was 82% in the RT-alone arm and 86% in the RT + ETA arm. No Grade 3 or 4 central nervous system or peripheral neuropathy was observed in the RT + ETA arm. Eighteen percent of the patients developed Grade 1 and 5% developed Grade 2 peripheral neuropathy. Other drug related toxicities included nausea/vomiting (27%), low blood counts (15%), and allergy (9%). Most of these toxicities were Grade 1 and 2. The incidence of severe acute and late radiation effects were similar between the two arms. The 2-year actuarial local-regional control rate (LCR) was 40% for the RT-alone arm and 40% for the RT + ETA arm. Two-year actuarial survival was 41% for the RT-alone arm and 43% for

  1. Version of the galaxy spiral structure model with opposite-directed arms and inter-arm links

    Energy Technology Data Exchange (ETDEWEB)

    Dolidze, M V [AN Gruzinskoj SSR, Abastumani. Abastumanskaya Astrofizicheskaya Observatoriya

    1963-05-01

    An attempt is made to explain some peculiarities of the local spiral structure and large-scale distribution of HII regions in the Galaxy by coexistence of the trailing and leading arm systems of different power and development. The existence of opposite-directed arms and inter-arm links in the circular zone (5-15 kpc) is analysed from the point of view of different Galaxy models.

  2. As good as the real thing? Performance differences for live versus recorded stimuli in an everyday listening task

    DEFF Research Database (Denmark)

    Kirkwood, Brent Christopher

    2005-01-01

    an acoustic head and torso simulator, and 3) diotic presentation of monaurally recorded stimuli. Live presentation of stimuli has already been used by C. Carello, et al. [Psychological Science 9, 211-214 (1998)] to demonstrate that humans can hear reasonably well the length of wooden dowels dropped onto hard...

  3. A randomized controlled trial comparing customized versus standard headrests for head and neck radiotherapy immobilization in terms of set-up errors, patient comfort and staff satisfaction (ICORG 08-09)

    International Nuclear Information System (INIS)

    Howlin, C.; O'Shea, E.; Dunne, M.; Mullaney, L.; McGarry, M.; Clayton-Lea, A.; Finn, M.; Carter, P.; Garret, B.; Thirion, P.

    2015-01-01

    Purpose: To recommend a specific headrest, customized or standard, for head and neck radiotherapy patients in our institution based primarily on an evaluation of set-up accuracy, taking into account a comparison of patient comfort, staff and patient satisfaction, and resource implications. Methods and materials: Between 2008 and 2009, 40 head and neck patients were randomized to either a standard (Arm A, n = 21) or customized (Arm B, n = 19) headrest, and immobilized with a customized thermoplastic mask. Set-up accuracy was assessed using electronic portal images (EPI). Random and systematic set-up errors for each arm were determined from 668 EPIs, which were analyzed by one Radiation Therapist. Patient comfort was assessed using a visual analogue scale (VAS) and staff satisfaction was measured using an in-house questionnaire. Resource implications were also evaluated. Results: The difference in set-up errors between arms was not significant in any direction. However, in this study the standard headrest (SH) arm performed well, with set-up errors comparative to customized headrests (CHs) in previous studies. CHs require regular monitoring and 47% were re-vacuumed making them more resource intensive. Patient comfort and staff satisfaction were comparable in both arms. Conclusion: The SH provided similar treatment accuracy and patient comfort compared with the CH. The large number of CHs that needed to be re-vacuumed undermines their reliability for radiotherapy schedules that extend beyond 34 days from the initial CT scan. Accordingly the CH was more resource intensive without improving the accuracy of positioning, thus the standard headrest is recommended for continued use at our institution

  4. Spiral-arm instability: giant clump formation via fragmentation of a galactic spiral arm

    Science.gov (United States)

    Inoue, Shigeki; Yoshida, Naoki

    2018-03-01

    Fragmentation of a spiral arm is thought to drive the formation of giant clumps in galaxies. Using linear perturbation analysis for self-gravitating spiral arms, we derive an instability parameter and define the conditions for clump formation. We extend our analysis to multicomponent systems that consist of gas and stars in an external potential. We then perform numerical simulations of isolated disc galaxies with isothermal gas, and compare the results with the prediction of our analytic model. Our model describes accurately the evolution of the spiral arms in our simulations, even when spiral arms dynamically interact with one another. We show that most of the giant clumps formed in the simulated disc galaxies satisfy the instability condition. The clump masses predicted by our model are in agreement with the simulation results, but the growth time-scale of unstable perturbations is overestimated by a factor of a few. We also apply our instability analysis to derive scaling relations of clump properties. The expected scaling relation between the clump size, velocity dispersion, and circular velocity is slightly different from that given by the Toomre instability analyses, but neither is inconsistent with currently available observations. We argue that the spiral-arm instability is a viable formation mechanism of giant clumps in gas-rich disc galaxies.

  5. Poly(glycolide multi-arm star polymers: Improved solubility via limited arm length

    Directory of Open Access Journals (Sweden)

    Florian K. Wolf

    2010-06-01

    Full Text Available Due to the low solubility of poly(glycolic acid (PGA, its use is generally limited to the synthesis of random copolyesters with other hydroxy acids, such as lactic acid, or to applications that permit direct processing from the polymer melt. Insolubility is generally observed for PGA when the degree of polymerization exceeds 20. Here we present a strategy that allows the preparation of PGA-based multi-arm structures which significantly exceed the molecular weight of processable oligomeric linear PGA (<1000 g/mol. This was achieved by the use of a multifunctional hyperbranched polyglycerol (PG macroinitiator and the tin(II-2-ethylhexanoate catalyzed ring-opening polymerization of glycolide in the melt. With this strategy it is possible to combine high molecular weight with good molecular weight control (up to 16,000 g/mol, PDI = 1.4–1.7, resulting in PGA multi-arm star block copolymers containing more than 90 wt % GA. The successful linkage of PGA arms and PG core via this core first/grafting from strategy was confirmed by detailed NMR and SEC characterization. Various PG/glycolide ratios were employed to vary the length of the PGA arms. Besides fluorinated solvents, the materials were soluble in DMF and DMSO up to an average arm length of 12 glycolic acid units. Reduction in the Tg and the melting temperature compared to the homopolymer PGA should lead to simplified processing conditions. The findings contribute to broadening the range of biomedical applications of PGA.

  6. School playground surfacing and arm fractures in children: a cluster randomized trial comparing sand to wood chip surfaces.

    Directory of Open Access Journals (Sweden)

    Andrew W Howard

    2009-12-01

    Full Text Available The risk of playground injuries, especially fractures, is prevalent in children, and can result in emergency room treatment and hospital admissions. Fall height and surface area are major determinants of playground fall injury risk. The primary objective was to determine if there was a difference in playground upper extremity fracture rates in school playgrounds with wood fibre surfacing versus granite sand surfacing. Secondary objectives were to determine if there were differences in overall playground injury rates or in head injury rates in school playgrounds with wood fibre surfacing compared to school playgrounds with granite sand surfacing.The cluster randomized trial comprised 37 elementary schools in the Toronto District School Board in Toronto, Canada with a total of 15,074 students. Each school received qualified funding for installation of new playground equipment and surfacing. The risk of arm fracture from playground falls onto granitic sand versus onto engineered wood fibre surfaces was compared, with an outcome measure of estimated arm fracture rate per 100,000 student-months. Schools were randomly assigned by computer generated list to receive either a granitic sand or an engineered wood fibre playground surface (Fibar, and were not blinded. Schools were visited to ascertain details of the playground and surface actually installed and to observe the exposure to play and to periodically monitor the depth of the surfacing material. Injury data, including details of circumstance and diagnosis, were collected at each school by a prospective surveillance system with confirmation of injury details through a validated telephone interview with parents and also through collection (with consent of medical reports regarding treated injuries. All schools were recruited together at the beginning of the trial, which is now closed after 2.5 years of injury data collection. Compliant schools included 12 schools randomized to Fibar that installed

  7. The Asteroid Redirect Mission (ARM)

    Science.gov (United States)

    Abell, Paul; Gates, Michele; Johnson, Lindley; Chodas, Paul; Mazanek, Dan; Reeves, David; Ticker, Ronald

    2016-07-01

    be made approximately a year before launch, but there is a strong recommendation from the scientific and resource utilization communities that the ARM target be volatile and organic rich. Three of the proposed candidates are carbonaceous NEAs. Specifically, the ARRM reference target, 2008 EV5 is a carbonaceous (C-type) asteroid that has been remotely characterized (via visual, infrared, and radar wavelengths), is believed to be hydrated, and provides significant return mass (boulders on the surface greater than 20 metric tons). It also has an advantage in that the orbital dynamics of the NEA fall within the current baseline mission timeline of five years between the return of the robotic vehicle to cis-lunar space and the launch of the ARCM. Therefore, NEA 2008 EV5 provides a valid target that can be used to help with formulation and development efforts. Input to ARM and Future Activities: In the fall of 2015, NASA chartered the Formulation Assessment and Support Team (FAST) to provide timely inputs for mission requirement formulation in support of the ARRM Requirements Closure Technical Interchange Meeting (TIM) in mid-December of 2015, to assist in developing an initial list of potential mission investigations, and to provide input on potential hosted payloads and partnerships. Expertise from the science, engineering, and technology communities was represented in exploring lines of inquiry related to key characteristics of the ARRM reference target asteroid (2008 EV5) for engineering design purposes. As of December 2015, the FAST has been formally retired and the FAST final report was publically released in February of 2016. However, plans have been made to stand up an ARM Investigation Team (IT), which is expected be formed in 2016. The multidisciplinary IT will assist with the definition and support of mission investigations, support ARM program-level and project-level functions, and support NASA Head-quarters interactions with the science and technology

  8. A low-noise measurement system for scanning thermal microscopy resistive nanoprobes based on a transformer ratio-arm bridge

    Science.gov (United States)

    Świątkowski, Michał; Wojtuś, Arkadiusz; Wielgoszewski, Grzegorz; Rudek, Maciej; Piasecki, Tomasz; Jóźwiak, Grzegorz; Gotszalk, Teodor

    2018-04-01

    Atomic force microscopy (AFM) is a widely used technology for the investigation and characterization of nanomaterials. Its functionality can be easily expanded by applying dedicated extension modules, which can measure the electrical conductivity or temperature of a sample. In this paper, we introduce a transformer ratio-arm bridge setup dedicated to AFM-based thermal imaging. One of the key features of the thermal module is the use of a low-power driving signal that prevents undesirable tip heating during resistance measurement, while the other is the sensor location in a ratio-arm transformer bridge working in the audio frequency range and ensuring galvanic isolation of the tip, enabling contact-mode scanning of electronic circuits. The proposed expansion module is compact and it can be integrated onto the AFM head close to the cantilever. The calibration process and the resolution of 11 mK of the proposed setup are shown.

  9. Arm Volumetry Versus Upper Extremity Lymphedema Index: Validity of Upper Extremity Lymphedema Index for Body-Type Corrected Arm Volume Evaluation.

    Science.gov (United States)

    Yamamoto, Nana; Yamamoto, Takumi; Hayashi, Nobuko; Hayashi, Akitatsu; Iida, Takuya; Koshima, Isao

    2016-06-01

    Volumetry, measurement of extremity volume, is a commonly used method for upper extremity lymphedema (UEL) evaluation. However, comparison between different patients with different physiques is difficult with volumetry, because body-type difference greatly affects arm volume. Seventy arms of 35 participants who had no history of arm edema or breast cancer were evaluated. Arm volume was calculated using a summed truncated cone model, and UEL index was calculated using circumferences and body mass index (BMI). Examinees' BMI was classified into 3 groups, namely, low BMI (BMI, 25 kg/m). Arm volume and UEL index were compared with corresponding BMI groups. Mean (SD) arm volume was 1090.9 (205.5) mL, and UEL index 96.9 (5.6). There were significant differences in arm volume between BMI groups [low BMI vs middle BMI vs high BMI, 945.2 (107.4) vs 1045.2 (87.5) vs 1443.1 (244.4) mL, P 0.5]. Arm volume significantly increased with increase of BMI, whereas UEL index stayed constant regardless of BMI. Upper extremity lymphedema index would allow better body-type corrected arm volume evaluation compared with arm volumetry.

  10. Modernization of African Armed Forces

    DEFF Research Database (Denmark)

    Mandrup, Thomas

    2015-01-01

    Concept paper framing the debate at the Dakar Forum Workshop on Modernization of Armed forces in Africa.......Concept paper framing the debate at the Dakar Forum Workshop on Modernization of Armed forces in Africa....

  11. Morphostructural characterization of female and young male of naturalized Sul-mato-grossenses “Pantaneiros” sheep

    Directory of Open Access Journals (Sweden)

    Daniele Portela de Oliveira

    2014-02-01

    Full Text Available Morphometric measurements are important to evaluate the variability, determine the racial standard and the existence of sexual dimorphism in genetic group. With this objective, were measured 20 morphometric measurements and one measurements of weight for 338 animals of the genetic group of Sul-mato-grossenses naturalized sheep belonging to Manoel de Barros Foundation and breeding at Centro Tecnologico de Ovinos from Anhanguera-Uniderp University and Federal University of the Grande Dourados. The statistical analyses were realized through software SAS. The females and young males showed short variation for morphometric measured of head and limbs region. However, higher variation was observed in the morphometric measurements taken from torso region, indicate that this region could be inserted in breeding programs like a selection criterion. The Pearson correlation coefficients between the morphostructural characteristics of females and young males, appears to have certain harmony degree in the morphostructural model. The females are characterized by animals with relatively large head, torso with proportional features and good angulations. The gender did not influence characteristics of the head region and body weight in the young animals. However, the characteristics of other regions, such as thoracic perimeter and posterior width of rump measured in the head region, and the perimeter of carpal and metacarpal in the limbs were influenced by gender in young animals.

  12. 21 CFR 890.3640 - Arm sling.

    Science.gov (United States)

    2010-04-01

    ... arm sling is a device intended for medical purposes to immobilize the arm, by means of a fabric band... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Arm sling. 890.3640 Section 890.3640 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES...

  13. Blood pressure measurement: one arm or both arm?

    Science.gov (United States)

    Kulkarni, Prasad K; Shekhar, Susheela; Reddy, B N; Nirmala, B C

    2011-09-01

    Guidelines for measuring blood pressure includes measurement of blood pressure on both arms but it is often ignored. Our case report aims at highlighting the need follow the guidelines. A 60 year old 59 kg weighing male asymptomatic patient without any comobidities was posted for bilateral inguinal hernia repair. The interarm blood pressure difference was discovered incidentally during his preanaesthetic evalution. On further evaluation patient was found to be having subclavian stenosis on left side which was asymptomatic. Intraoperative and post operative period was uneventful. Blood pressure measurement should be done in accordance with the stipulated guidelines. Inter arm blood pressure difference should be noted in all patients as not only for diagnosis and treatment of hypertension but also as a tool to diagnose asymptomatic peripheral vascular disesase.

  14. ARM assembly language with hardware experiments

    CERN Document Server

    Elahi, Ata

    2015-01-01

    This book provides a hands-on approach to learning ARM assembly language with the use of a TI microcontroller. The book starts with an introduction to computer architecture and then discusses number systems and digital logic. The text covers ARM Assembly Language, ARM Cortex Architecture and its components, and Hardware Experiments using TILM3S1968. Written for those interested in learning embedded programming using an ARM Microcontroller. ·         Introduces number systems and signal transmission methods   ·         Reviews logic gates, registers, multiplexers, decoders and memory   ·         Provides an overview and examples of ARM instruction set   ·         Uses using Keil development tools for writing and debugging ARM assembly language Programs   ·         Hardware experiments using a Mbed NXP LPC1768 microcontroller; including General Purpose Input/Output (GPIO) configuration, real time clock configuration, binary input to 7-segment display, creating ...

  15. PHENIX Muon Arms

    International Nuclear Information System (INIS)

    Akikawa, H.; Al-Jamel, A.; Archuleta, J.B.; Archuleta, J.R.; Armendariz, R.; Armijo, V.; Awes, T.C.; Baldisseri, A.; Barker, A.B.; Barnes, P.D.; Bassalleck, B.; Batsouli, S.; Behrendt, J.; Bellaiche, F.G.; Bland, A.W.; Bobrek, M.; Boissevain, J.G.; Borel, H.; Brooks, M.L.; Brown, A.W.; Brown, D.S.; Bruner, N.; Cafferty, M.M.; Carey, T.A.; Chai, J.-S.; Chavez, L.L.; Chollet, S.; Choudhury, R.K.; Chung, M.S.; Cianciolo, V.; Clark, D.J.; Cobigo, Y.; Dabrowski, C.M.; Debraine, A.; DeMoss, J.; Dinesh, B.V.; Drachenberg, J.L.; Drapier, O.; Echave, M.A.; Efremenko, Y.V.; En'yo, H.; Fields, D.E.; Fleuret, F.; Fried, J.; Fujisawa, E.; Funahashi, H.; Gadrat, S.; Gastaldi, F.; Gee, T.F.; Glenn, A.; Gogiberidze, G.; Gonin, M.; Gosset, J.; Goto, Y.; Granier de Cassagnac, R.; Hance, R.H.; Hart, G.W.; Hayashi, N.; Held, S.; Hicks, J.S.; Hill, J.C.; Hoade, R.; Hong, B.; Hoover, A.; Horaguchi, T.; Hunter, C.T.; Hurst, D.E.; Ichihara, T.; Imai, K.; Isenhower, L.D.L. Davis; Isenhower, L.D.L. Donald; Ishihara, M.; Jang, W.Y.; Johnson, J.; Jouan, D.; Kamihara, N.; Kamyshkov, Y.; Kang, J.H.; Kapoor, S.S.; Kim, D.J.; Kim, D.-W.; Kim, G.-B.; Kinnison, W.W.; Klinksiek, S.; Kluberg, L.; Kobayashi, H.; Koehler, D.; Kotchenda, L.; Kuberg, C.H.; Kurita, K.; Kweon, M.J.; Kwon, Y.; Kyle, G.S.; LaBounty, J.J.; Lajoie, J.G.; Lee, D.M.; Lee, S.; Leitch, M.J.; Li, Z.; Liu, M.X.; Liu, X.; Liu, Y.; Lockner, E.; Lopez, J.D.; Mao, Y.; Martinez, X.B.; McCain, M.C.; McGaughey, P.L.; Mioduszewski, S.; Mischke, R.E.; Mohanty, A.K.; Montoya, B.C.; Moss, J.M.; Murata, J.; Murray, M.M.; Nagle, J.L.; Nakada, Y.; Newby, J.; Obenshain, F.; Palounek, A.P.T.; Papavassiliou, V.; Pate, S.F.; Plasil, F.; Pope, K.; Qualls, J.M.; Rao, G.; Read, K.F.; Robinson, S.H.; Roche, G.; Romana, A.; Rosnet, P.; Roth, R.; Saito, N.; Sakuma, T.; Sandhoff, W.F.; Sanfratello, L.; Sato, H.D.; Savino, R.; Sekimoto, M.; Shaw, M.R.; Shibata, T.-A.; Sim, K.S.; Skank, H.D.; Smith, D.E.; Smith, G.D.; Sondheim, W.E.; Sorensen, S.; Staley, F.; Stankus, P.W.; Steffens, S.; Stein, E.M.; Stepanov, M.; Stokes, W.; Sugioka, M.; Sun, Z.; Taketani, A.; Taniguchi, E.; Tepe, J.D.; Thornton, G.W.; Tian, W.; Tojo, J.; Torii, H.; Towell, R.S.; Tradeski, J.; Vassent, M.; Velissaris, C.; Villatte, L.; Wan, Y.; Watanabe, Y.; Watkins, L.C.; Whitus, B.R.; Williams, C.; Willis, P.S.; Wong-Swanson, B.G.; Yang, Y.; Yoneyama, S.; Young, G.R.; Zhou, S.

    2003-01-01

    The PHENIX Muon Arms detect muons at rapidities of |y|=(1.2-2.4) with full azimuthal acceptance. Each muon arm must track and identify muons and provide good rejection of pions and kaons (∼10 -3 ). In order to accomplish this we employ a radial field magnetic spectrometer with precision tracking (Muon Tracker) followed by a stack of absorber/low resolution tracking layers (Muon Identifier). The design, construction, testing and expected run parameters of both the muon tracker and the muon identifier are described

  16. PHENIX Muon Arms

    Energy Technology Data Exchange (ETDEWEB)

    Akikawa, H.; Al-Jamel, A.; Archuleta, J.B.; Archuleta, J.R.; Armendariz, R.; Armijo, V.; Awes, T.C.; Baldisseri, A.; Barker, A.B.; Barnes, P.D.; Bassalleck, B.; Batsouli, S.; Behrendt, J.; Bellaiche, F.G.; Bland, A.W.; Bobrek, M.; Boissevain, J.G.; Borel, H.; Brooks, M.L.; Brown, A.W.; Brown, D.S.; Bruner, N.; Cafferty, M.M.; Carey, T.A.; Chai, J.-S.; Chavez, L.L.; Chollet, S.; Choudhury, R.K.; Chung, M.S.; Cianciolo, V.; Clark, D.J.; Cobigo, Y.; Dabrowski, C.M.; Debraine, A.; DeMoss, J.; Dinesh, B.V.; Drachenberg, J.L.; Drapier, O.; Echave, M.A.; Efremenko, Y.V.; En' yo, H.; Fields, D.E.; Fleuret, F.; Fried, J.; Fujisawa, E.; Funahashi, H.; Gadrat, S.; Gastaldi, F.; Gee, T.F.; Glenn, A.; Gogiberidze, G.; Gonin, M.; Gosset, J.; Goto, Y.; Granier de Cassagnac, R.; Hance, R.H.; Hart, G.W.; Hayashi, N.; Held, S.; Hicks, J.S.; Hill, J.C.; Hoade, R.; Hong, B.; Hoover, A.; Horaguchi, T.; Hunter, C.T.; Hurst, D.E.; Ichihara, T.; Imai, K.; Isenhower, L.D.L. Davis; Isenhower, L.D.L. Donald; Ishihara, M.; Jang, W.Y.; Johnson, J.; Jouan, D.; Kamihara, N.; Kamyshkov, Y.; Kang, J.H.; Kapoor, S.S.; Kim, D.J.; Kim, D.-W.; Kim, G.-B.; Kinnison, W.W.; Klinksiek, S.; Kluberg, L.; Kobayashi, H.; Koehler, D.; Kotchenda, L.; Kuberg, C.H.; Kurita, K.; Kweon, M.J.; Kwon, Y.; Kyle, G.S.; LaBounty, J.J.; Lajoie, J.G.; Lee, D.M.; Lee, S.; Leitch, M.J.; Li, Z.; Liu, M.X.; Liu, X.; Liu, Y.; Lockner, E.; Lopez, J.D.; Mao, Y.; Martinez, X.B.; McCain, M.C.; McGaughey, P.L.; Mioduszewski, S.; Mischke, R.E.; Mohanty, A.K.; Montoya, B.C.; Moss, J.M.; Murata, J.; Murray, M.M.; Nagle, J.L.; Nakada, Y.; Newby, J.; Obenshain, F.; Palounek, A.P.T.; Papavassiliou, V.; Pate, S.F.; Plasil, F.; Pope, K.; Qualls, J.M.; Rao, G.; Read, K.F. E-mail: readkf@ornl.gov; Robinson, S.H.; Roche, G.; Romana, A.; Rosnet, P.; Roth, R.; Saito, N.; Sakuma, T.; Sandhoff, W.F.; Sanfratello, L.; Sato, H.D.; Savino, R.; Sekimoto, M.; Shaw, M.R.; Shibata, T.-A.; Sim, K.S.; Skank, H.D.; Smith, D.E.; Smith, G.D. [and others

    2003-03-01

    The PHENIX Muon Arms detect muons at rapidities of |y|=(1.2-2.4) with full azimuthal acceptance. Each muon arm must track and identify muons and provide good rejection of pions and kaons ({approx}10{sup -3}). In order to accomplish this we employ a radial field magnetic spectrometer with precision tracking (Muon Tracker) followed by a stack of absorber/low resolution tracking layers (Muon Identifier). The design, construction, testing and expected run parameters of both the muon tracker and the muon identifier are described.

  17. Kootenay Lake Fertilization Experiment, Year 15 (North Arm) and Year 3 (South Arm) (2006) Report

    Energy Technology Data Exchange (ETDEWEB)

    Schindler, E.U.; Sebastian, D.; Andrusak, G.F. [Fish and Wildlife Science and Allocation, Ministry of Environment, Province of British Columbia

    2009-07-01

    This report summarizes results from the fifteenth year (2006) of nutrient additions to the North Arm of Kootenay Lake and three years of nutrient additions to the South Arm. Experimental fertilization of the lake has been conducted using an adaptive management approach in an effort to restore lake productivity lost as a result of nutrient uptake in upstream reservoirs. The primary objective of the experiment is to restore kokanee (Oncorhynchus nerka) populations, which are the main food source for Gerrard rainbow trout (Oncorhynchus mykiss) and bull trout (Salvelinus confluentus). The quantity of agricultural grade liquid fertilizer (10-34-0, ammonium polyphosphate and 28-0-0, urea ammonium nitrate) added to the North Arm in 2006 was 44.7 tonnes of P and 248.4 tonnes of N. The total fertilizer load added to the South Arm was 257 tonnes of nitrogen; no P was added. Kootenay Lake has an area of 395 km{sup 2}, a maximum depth of 150 m, a mean depth of 94 m, and a water renewal time of approximately two years. Kootenay Lake is a monomictic lake, generally mixing from late fall to early spring and stratifying during the summer. Surface water temperatures generally exceed 20 C for only a few weeks in July. Results of oxygen profiles were similar to previous years with the lake being well oxygenated from the surface to the bottom depths at all stations. Similar to past years, Secchi disc measurements at all stations in 2006 indicate a typical seasonal pattern of decreasing depths associated with the spring phytoplankton bloom, followed by increasing depths as the bloom gradually decreases by the late summer and fall. Total phosphorus (TP) ranged from 2-7 {micro}g/L and tended to decrease as summer advanced. Over the sampling season dissolved inorganic nitrogen (DIN) concentrations decreased, with the decline corresponding to nitrate (the dominant component of DIN) being utilized by phytoplankton during summer stratification. Owing to the importance of epilimnetic nitrate

  18. Association between intramuscular fat in the arm following arm training and INSIG2

    DEFF Research Database (Denmark)

    Popadic Gacesa, J Z; Secher, N H; Momcilovic, M

    2014-01-01

    ) ; mean ± standard deviation) carried out a 12-week two-arm elbow extensor training (10 maximal extensions with 1 min recovery between bouts) five times per day, five times per week. For 17 volunteers, upper arm muscle and adipose tissue [subcutaneous (SCAT) and intramuscular (IMAT)] volumes were.......0 ± 0.9%; GC/CC: %IMAT 0.6 ± 0.5% (P > 0.05). However, in the year following the training, accumulation of upper arm IMAT was twice as large in participants homozygous for the G allele (GG: Δ%IMAT +2.5 ± 0.8%; GC/CC: Δ%IMAT +1.1 ± 0.7%; P 

  19. Design of a biomimetic robotic octopus arm.

    Science.gov (United States)

    Laschi, C; Mazzolai, B; Mattoli, V; Cianchetti, M; Dario, P

    2009-03-01

    This paper reports the rationale and design of a robotic arm, as inspired by an octopus arm. The octopus arm shows peculiar features, such as the ability to bend in all directions, to produce fast elongations, and to vary its stiffness. The octopus achieves these unique motor skills, thanks to its peculiar muscular structure, named muscular hydrostat. Different muscles arranged on orthogonal planes generate an antagonistic action on each other in the muscular hydrostat, which does not change its volume during muscle contractions, and allow bending and elongation of the arm and stiffness variation. By drawing inspiration from natural skills of octopus, and by analysing the geometry and mechanics of the muscular structure of its arm, we propose the design of a robot arm consisting of an artificial muscular hydrostat structure, which is completely soft and compliant, but also able to stiffen. In this paper, we discuss the design criteria of the robotic arm and how this design and the special arrangement of its muscular structure may bring the building of a robotic arm into being, by showing the results obtained by mathematical models and prototypical mock-ups.

  20. Design of a biomimetic robotic octopus arm

    Energy Technology Data Exchange (ETDEWEB)

    Laschi, C; Cianchetti, M [Advanced Robotics Technology and Systems Laboratory, Scuola Superiore Sant' Anna, Pisa (Italy); Mazzolai, B; Dario, P [Italian Institute of Technology, Genova (Italy); Mattoli, V [Centre of Research in Microengineering Laboratory, Scuola Superiore Sant' Anna, Pisa (Italy)], E-mail: cecilia.laschi@sssup.it

    2009-03-01

    This paper reports the rationale and design of a robotic arm, as inspired by an octopus arm. The octopus arm shows peculiar features, such as the ability to bend in all directions, to produce fast elongations, and to vary its stiffness. The octopus achieves these unique motor skills, thanks to its peculiar muscular structure, named muscular hydrostat. Different muscles arranged on orthogonal planes generate an antagonistic action on each other in the muscular hydrostat, which does not change its volume during muscle contractions, and allow bending and elongation of the arm and stiffness variation. By drawing inspiration from natural skills of octopus, and by analysing the geometry and mechanics of the muscular structure of its arm, we propose the design of a robot arm consisting of an artificial muscular hydrostat structure, which is completely soft and compliant, but also able to stiffen. In this paper, we discuss the design criteria of the robotic arm and how this design and the special arrangement of its muscular structure may bring the building of a robotic arm into being, by showing the results obtained by mathematical models and prototypical mock-ups.

  1. Design of a biomimetic robotic octopus arm

    International Nuclear Information System (INIS)

    Laschi, C; Cianchetti, M; Mazzolai, B; Dario, P; Mattoli, V

    2009-01-01

    This paper reports the rationale and design of a robotic arm, as inspired by an octopus arm. The octopus arm shows peculiar features, such as the ability to bend in all directions, to produce fast elongations, and to vary its stiffness. The octopus achieves these unique motor skills, thanks to its peculiar muscular structure, named muscular hydrostat. Different muscles arranged on orthogonal planes generate an antagonistic action on each other in the muscular hydrostat, which does not change its volume during muscle contractions, and allow bending and elongation of the arm and stiffness variation. By drawing inspiration from natural skills of octopus, and by analysing the geometry and mechanics of the muscular structure of its arm, we propose the design of a robot arm consisting of an artificial muscular hydrostat structure, which is completely soft and compliant, but also able to stiffen. In this paper, we discuss the design criteria of the robotic arm and how this design and the special arrangement of its muscular structure may bring the building of a robotic arm into being, by showing the results obtained by mathematical models and prototypical mock-ups

  2. Arm-in-Arm Response Regulator Dimers Promote Intermolecular Signal Transduction

    Energy Technology Data Exchange (ETDEWEB)

    Baker, Anna W.; Satyshur, Kenneth A.; Morales, Neydis Moreno; Forest, Katrina T. (UW)

    2016-02-01

    ABSTRACT

    Bacteriophytochrome photoreceptors (BphPs) and their cognate response regulators make up two-component signal transduction systems which direct bacteria to mount phenotypic responses to changes in environmental light quality. Most of these systems utilize single-domain response regulators to transduce signals through unknown pathways and mechanisms. Here we describe the photocycle and autophosphorylation kinetics of RtBphP1, a red light-regulated histidine kinase from the desert bacteriumRamlibacter tataouinensis. RtBphP1 undergoes red to far-red photoconversion with rapid thermal reversion to the dark state. RtBphP1 is autophosphorylated in the dark; this activity is inhibited under red light. The RtBphP1 cognate response regulator, theR. tataouinensisbacteriophytochrome response regulator (RtBRR), and a homolog, AtBRR fromAgrobacterium tumefaciens, crystallize unexpectedly as arm-in-arm dimers, reliant on a conserved hydrophobic motif, hFWAhL (where h is a hydrophobic M, V, L, or I residue). RtBRR and AtBRR dimerize distinctly from four structurally characterized phytochrome response regulators found in photosynthetic organisms and from all other receiver domain homodimers in the Protein Data Bank. A unique cacodylate-zinc-histidine tag metal organic framework yielded single-wavelength anomalous diffraction phases and may be of general interest. Examination of the effect of the BRR stoichiometry on signal transduction showed that phosphorylated RtBRR is accumulated more efficiently than the engineered monomeric RtBRR (RtBRRmon) in phosphotransfer reactions. Thus, we conclude that arm-in-arm dimers are a relevant signaling intermediate in this class of two-component regulatory systems.

  3. How does a planet excite multiple spiral arms?

    Science.gov (United States)

    Bae, Jaehan; Zhu, Zhaohuan

    2018-01-01

    Protoplanetary disk simulations show that a single planet excites multiple spiral arms in the background disk, potentially supported by the multi-armed spirals revealed with recent high-resolution observations in some disks. The existence of multiple spiral arms is of importance in many aspects. It is empirically found that the arm-to-arm separation increases as a function of the planetary mass, so one can use the morphology of observed spiral arms to infer the mass of unseen planets. In addition, a spiral arm opens a radial gap as it steepens into a shock, so when a planet excites multiple spiral arms it can open multiple gaps in the disk. Despite the important implications, however, the formation mechanism of multiple spiral arms has not been fully understood by far.In this talk, we explain how a planet excites multiple spiral arms. The gravitational potential of a planet can be decomposed into a Fourier series, a sum of individual azimuthal modes having different azimuthal wavenumbers. Using a linear wave theory, we first demonstrate that appropriate sets of Fourier decomposed waves can be in phase, raising a possibility that constructive interference among the waves can produce coherent structures - spiral arms. More than one spiral arm can form since such constructive interference can occur at different positions in the disk for different sets of waves. We then verify this hypothesis using a suite of two-dimensional hydrodynamic simulations. Finally, we present non-linear behavior in the formation of multiple spiral arms.

  4. Managing new arms races

    International Nuclear Information System (INIS)

    Segal, G.

    1992-01-01

    The management of new arms races in the region of Asia-Pacific includes considerations of weapons trade and transfer in the region, with an emphasis on nuclear weapons proliferation. It deals with the problem of controlling the arms trade and the efforts to control conventional weapons and underlines the possible role and influence of Conference on Cooperation and Security in Europe (CSCE)

  5. A Comparison of Image Quality and Radiation Exposure Between the Mini C-Arm and the Standard C-Arm.

    Science.gov (United States)

    van Rappard, Juliaan R M; Hummel, Willy A; de Jong, Tijmen; Mouës, Chantal M

    2018-04-01

    The use of intraoperative fluoroscopy has become mandatory in osseous hand surgery. Due to its overall practicality, the mini C-arm has gained popularity among hand surgeons over the standard C-arm. This study compares image quality and radiation exposure for patient and staff between the mini C-arm and the standard C-arm, both with flat panel technology. An observer-based subjective image quality study was performed using a contrast detail (CD) phantom. Five independent observers were asked to determine the smallest circles discernable to them. The results were plotted in a graph, forming a CD curve. From each curve, an image quality figure (IQF) was derived. A lower IQF equates to a better image quality. The patients' entrance skin dose was measured, and to obtain more information about the staff exposure dose, a perspex hand phantom was used. The scatter radiation was measured at various distances and angles relative to a central point on the detector. The IQF was significantly lower for the mini C-arm resulting in a better image quality. The patients' entrance dose was 10 times higher for the mini C-arm as compared with the standard C-arm, and the scatter radiation threefold. Due to its improved image quality and overall practicality, the mini C-arm is recommended for hand surgical procedures. To ensure that the surgeons' radiation exposure is not exceeding the safety limits, monitoring radiation exposure using mini C-arms with flat panel technology during surgery should be done in a future clinical study.

  6. The potential of laser cutting and snake arm robots in aspects of nuclear decommissioning

    International Nuclear Information System (INIS)

    Hilton, Paul; Khan, Ali

    2013-01-01

    This paper will describe recent work conducted in the UK to highlight the potential of applying high power laser cutting to aspects of decommissioning and dismantling in the nuclear sector. A major driver for this activity is size reduction of metallic structures, vessels and tubing, with the objective of efficient stacking of the cut parts for future long term storage. TWI have used a standard 5 kW multi-mode laser with fibre optic delivery of the beam, to demonstrate techniques for cutting stainless steel tubing, at diameters up to 150 mm and wall thicknesses up to 7 mm, and various thicknesses of plate materials. Using specially developed cutting heads, employing long focal length lenses to form the beam, techniques were developed to allow the cutting of tubes from one side only and without changing the focal position of the laser beam with respect to the diameter of the tube perpendicular to the incident beam. The latter means that remote programming of the cutting path becomes much simpler. For cutting plate materials, special gas nozzle dynamics have produced great tolerance of the cutting process to stand-off distance (the distance between the surface of the material being cut and the exit of the cutting nozzle). One particularly interesting method of remote deployment of these cutting techniques is to use 'snake arm' robots. These robots, by nature of their construction, can access areas un-accessible using other techniques. This of course makes them particularly suited to aspects of nuclear decommissioning, particularly in what are termed 'un-structured environments', where the exact disposition of items encountered is not known. The paper will also describe the first time a laser cutting head has been installed on the end of a snake arm robot and the combination used in a simulated nuclear cutting application. (author)

  7. 49 CFR 572.131 - General description.

    Science.gov (United States)

    2010-10-01

    ... are listed in Table A; (2) Parts List and Drawings, Part 572 Subpart O Hybrid III Fifth Percentile...)). Table A Component assembly Drawing No. Head Assembly 880105-100X Neck Assembly 880105-250 Upper Torso...-2 (b) Adjacent segments are joined in a manner such that, except for contacts existing under static...

  8. Changes in arm-hand function and arm-hand skill performance in patients after stroke during and after rehabilitation.

    Science.gov (United States)

    Franck, Johan Anton; Smeets, Rob Johannes Elise Marie; Seelen, Henk Alexander Maria

    2017-01-01

    Arm-hand rehabilitation programs applied in stroke rehabilitation frequently target specific populations and thus are less applicable in heterogeneous patient populations. Besides, changes in arm-hand function (AHF) and arm-hand skill performance (AHSP) during and after a specific and well-described rehabilitation treatment are often not well evaluated. This single-armed prospective cohort study featured three subgroups of stroke patients with either a severely, moderately or mildly impaired AHF. Rehabilitation treatment consisted of a Concise_Arm_and_hand_ Rehabilitation_Approach_in_Stroke (CARAS). Measurements at function and activity level were performed at admission, clinical discharge, 3, 6, 9 and 12 months after clinical discharge. Eighty-nine stroke patients (M/F:63/23; mean age:57.6yr (+/-10.6); post-stroke time:29.8 days (+/-20.1)) participated. All patients improved on AHF and arm-hand capacity during and after rehabilitation, except on grip strength in the severely affected subgroup. Largest gains occurred in patients with a moderately affected AHF. As to self-perceived AHSP, on average, all subgroups improved over time. A small percentage of patients declined regarding self-perceived AHSP post-rehabilitation. A majority of stroke patients across the whole arm-hand impairment severity spectrum significantly improved on AHF, arm-hand capacity and self-perceived AHSP. These were maintained up to one year post-rehabilitation. Results may serve as a control condition in future studies.

  9. Calculations of radiation fields and monkey mid-head and mid-thorax responses in AFRRI-TRIGA reactor facility experiments

    International Nuclear Information System (INIS)

    Johnson, J.O.; Emmett, M.B.; Pace, J.V. III.

    1983-07-01

    A computational study was performed to characterize the radiation exposure fields and the mid-head and mid-thorax response functions for monkeys irradiated in the Armed Forces Radiobiological Research Institute (AFRRI) reactor exposure facilities. Discrete ordinates radiation transport calculations were performed in one-dimensional spherical geometry to obtain the energy spectra of the neutrons and gamma rays entering the room through various spectrum modifiers and reaching the irradiation position. Adjoint calculations performed in two-dimensional cylindrical geometry yielded the mid-head and mid-thorax response functions, which were then folded with flux spectra to obtain the monkey mid-head and mid-thorax doses (kerma rates) received at the irradiation position. The results of the study are presented both as graphs and as tables. The resulting spectral shapes compared favorably with previous work; however, the magnitudes of the fluxes did not. The differences in the magnitudes may be due to the normalization factor used

  10. Impact of extraneous mispositioned events on motion-corrected brain SPECT images of freely moving animals

    International Nuclear Information System (INIS)

    Angelis, Georgios I.; Ryder, William J.; Bashar, Rezaul; Meikle, Steven R.; Fulton, Roger R.

    2014-01-01

    Purpose: Single photon emission computed tomography (SPECT) brain imaging of freely moving small animals would allow a wide range of important neurological processes and behaviors to be studied, which are normally inhibited by anesthetic drugs or precluded due to the animal being restrained. While rigid body motion of the head can be tracked and accounted for in the reconstruction, activity in the torso may confound brain measurements, especially since motion of the torso is more complex (i.e., nonrigid) and not well correlated with that of the head. The authors investigated the impact of mispositioned events and attenuation due to the torso on the accuracy of motion corrected brain images of freely moving mice. Methods: Monte Carlo simulations of a realistic voxelized mouse phantom and a dual compartment phantom were performed. Each phantom comprised a target and an extraneous compartment which were able to move independently of each other. Motion correction was performed based on the known motion of the target compartment only. Two SPECT camera geometries were investigated: a rotating single head detector and a stationary full ring detector. The effects of motion, detector geometry, and energy of the emitted photons (hence, attenuation) on bias and noise in reconstructed brain regions were evaluated. Results: The authors observed two main sources of bias: (a) motion-related inconsistencies in the projection data and (b) the mismatch between attenuation and emission. Both effects are caused by the assumption that the orientation of the torso is difficult to track and model, and therefore cannot be conveniently corrected for. The motion induced bias in some regions was up to 12% when no attenuation effects were considered, while it reached 40% when also combined with attenuation related inconsistencies. The detector geometry (i.e., rotating vs full ring) has a big impact on the accuracy of the reconstructed images, with the full ring detector being more

  11. Development of a detection system for head movement robust to illumination change at radiotherapy

    International Nuclear Information System (INIS)

    Yamakawa, Takuya; Ogawa, Koichi; Iyatomi, Hitoshi; Kunieda, Etsuo

    2010-01-01

    This study reports the development of a detection system for head movement at stereotactic radio-therapy of head tumors. In the system, the pattern matching algorithm is applied as follows. Regions of interest like the nose and right/ left ears, the objects of movement to be traced, are selected by GUI (graphical user interface) from pictures taken by 3 USB cameras (DC-NCR20U, Hanwha, Japan) set around the head on the supportive arms to make the template of standard position; the frame pictures (5 fps) inputted as the real-time monitor are matched to the template so that the actual movement can be detected by the distance between the template and collation points; and precision is improved by calculating mean square errors. Alarming is set when the movement exceeds the permissible range. At the actual clinical site, as the wrong detection of the movement occurs by illumination change caused by the gantry migration, infrared pictures are taken in place of the ordinary room light condition. This results in reduction of position errors from 16.7, 9.5 and 8.1 mm (the latter light condition) to 0.6, 0.3 and 0.2 mm (infrared), of the nose, right and left ears, respectively. Thus a detection system for head movement robust (error <1 mm) to illumination change at radio-therapy is established. (T.T.)

  12. Detection of the spatial accuracy of an O-arm in the region of surgical interest

    Science.gov (United States)

    Koivukangas, Tapani; Katisko, Jani P. A.; Koivukangsa, John P.

    2013-03-01

    Medical imaging is an essential component of a wide range of surgical procedures1. For image guided surgical (IGS) procedures, medical images are the main source of information2. The IGS procedures rely largely on obtained image data, so the data needs to provide differentiation between normal and abnormal tissues, especially when other surgical guidance devices are used in the procedures. The image data also needs to provide accurate spatial representation of the patient3. This research has concentrated on the concept of accuracy assessment of IGS devices to meet the needs of quality assurance in the hospital environment. For this purpose, two precision engineered accuracy assessment phantoms have been developed as advanced materials and methods for the community. The phantoms were designed to mimic the volume of a human head as the common region of surgical interest (ROSI). This paper introduces the utilization of the phantoms in spatial accuracy assessment of a commercial surgical 3D CT scanner, the O-Arm. The study presents methods and results of image quality detection of possible geometrical distortions in the region of surgical interest. The results show that in the pre-determined ROSI there are clear image distortion and artefacts using too high imaging parameters when scanning the objects. On the other hand, when using optimal parameters, the O-Arm causes minimal error in IGS accuracy. The detected spatial inaccuracy of the O-Arm with used parameters was in the range of less than 1.00 mm.

  13. Embodied intersubjective engagement in mother-infant tactile communication: a cross-cultural study of Japanese and Scottish mother-infant behaviors during infant pick-up.

    Science.gov (United States)

    Negayama, Koichi; Delafield-Butt, Jonathan T; Momose, Keiko; Ishijima, Konomi; Kawahara, Noriko; Lux, Erin J; Murphy, Andrew; Kaliarntas, Konstantinos

    2015-01-01

    This study examines the early development of cultural differences in a simple, embodied, and intersubjective engagement between mothers putting down, picking up, and carrying their infants between Japan and Scotland. Eleven Japanese and ten Scottish mothers with their 6- and then 9-month-old infants participated. Video and motion analyses were employed to measure motor patterns of the mothers' approach to their infants, as well as their infants' collaborative responses during put-down, pick-up, and carry phases. Japanese and Scottish mothers approached their infants with different styles and their infants responded differently to the short duration of separation during the trial. A greeting-like behavior of the arms and hands was prevalent in the Scottish mothers' approach, but not in the Japanese mothers' approach. Japanese mothers typically kneeled before making the final reach to pick-up their children, giving a closer, apparently gentler final approach of the torso than Scottish mothers, who bent at the waist with larger movements of the torso. Measures of the gap closure between the mothers' hands to their infants' heads revealed variably longer duration and distance gap closures with greater velocity by the Scottish mothers than by the Japanese mothers. Further, the sequence of Japanese mothers' body actions on approach, contact, pick-up, and hold was more coordinated at 6 months than at 9 months. Scottish mothers were generally more variable on approach. Measures of infant participation and expressivity indicate more active participation in the negotiation during the separation and pick-up phases by Scottish infants. Thus, this paper demonstrates a culturally different onset of development of joint attention in pick-up. These differences reflect cultures of everyday interaction.

  14. Embodied intersubjective engagement in mother–infant tactile communication: a cross-cultural study of Japanese and Scottish mother–infant behaviors during infant pick-up

    Science.gov (United States)

    Negayama, Koichi; Delafield-Butt, Jonathan T.; Momose, Keiko; Ishijima, Konomi; Kawahara, Noriko; Lux, Erin J.; Murphy, Andrew; Kaliarntas, Konstantinos

    2015-01-01

    This study examines the early development of cultural differences in a simple, embodied, and intersubjective engagement between mothers putting down, picking up, and carrying their infants between Japan and Scotland. Eleven Japanese and ten Scottish mothers with their 6- and then 9-month-old infants participated. Video and motion analyses were employed to measure motor patterns of the mothers’ approach to their infants, as well as their infants’ collaborative responses during put-down, pick-up, and carry phases. Japanese and Scottish mothers approached their infants with different styles and their infants responded differently to the short duration of separation during the trial. A greeting-like behavior of the arms and hands was prevalent in the Scottish mothers’ approach, but not in the Japanese mothers’ approach. Japanese mothers typically kneeled before making the final reach to pick-up their children, giving a closer, apparently gentler final approach of the torso than Scottish mothers, who bent at the waist with larger movements of the torso. Measures of the gap closure between the mothers’ hands to their infants’ heads revealed variably longer duration and distance gap closures with greater velocity by the Scottish mothers than by the Japanese mothers. Further, the sequence of Japanese mothers’ body actions on approach, contact, pick-up, and hold was more coordinated at 6 months than at 9 months. Scottish mothers were generally more variable on approach. Measures of infant participation and expressivity indicate more active participation in the negotiation during the separation and pick-up phases by Scottish infants. Thus, this paper demonstrates a culturally different onset of development of joint attention in pick-up. These differences reflect cultures of everyday interaction. PMID:25774139

  15. CHARACTERISTICS OF SPIRAL ARMS IN LATE-TYPE GALAXIES

    International Nuclear Information System (INIS)

    Honig, Z. N.; Reid, M. J.

    2015-01-01

    We have measured the positions of large numbers of H II regions in four nearly face-on, late-type, spiral galaxies: NGC 628 (M74), NGC 1232, NGC 3184, and NGC 5194 (M51). Fitting log-periodic spiral models to segments of each arm yields local estimates of spiral pitch angle and arm width. While pitch angles vary considerably along individual arms, among arms within a galaxy, and among galaxies, we find no systematic trend with galactocentric distance. We estimate the widths of the arm segments from the scatter in the distances of the H II regions from the spiral model. All major arms in these galaxies show spiral arm width increasing with distance from the galactic center, similar to the trend seen in the Milky Way. However, in the outermost parts of the galaxies, where massive star formation declines, some arms reverse this trend and narrow. We find that spiral arms often appear to be composed of segments of ∼5 kpc length, which join to form kinks and abrupt changes in pitch angle and arm width; these characteristics are consistent with properties seen in the large N-body simulations of D'Onghia et al. and others

  16. Training the Unimpaired Arm Improves the Motion of the Impaired Arm and the Sitting Balance in Chronic Stroke Survivors.

    Science.gov (United States)

    De Luca, Alice; Giannoni, Psiche; Vernetti, Honore; Capra, Cristina; Lentino, Carmelo; Checchia, Giovanni Antonio; Casadio, Maura

    2017-07-01

    Robot-assisted rehabilitation of stroke survivors mainly focuses on the impaired side of the body while the role of the unimpaired side in the recovery after stroke is still controversial. The goal of this study is to investigate the influence on sitting balance and paretic arm functions of a training protocol based on movements of the unimpaired arm. Sixteen chronic stroke survivors underwent nineteen training sessions, in which they performed active movements with the unimpaired arm supported by a passive exoskeleton. Performance of the trunk and upper limbs was evaluated before treatment, after treatment and at six months follow up with clinical scales and an instrumented evaluation. A reaching test executed with the exoskeleton was used to assess changes in performance of both arms. The treatment based on the unimpaired arm's movements executed with a correct body posture led to benefits in control of the trunk and of both the trained and the untrained arm. The amount of impaired arm improvement in the Fugl-Meyer score was comparable to the outcome of robotic treatments focused directly on this arm. Our results highlight the importance of taking into account all body schema in the rehabilitation robotic program, instead of focusing only on the impaired side of the body.

  17. Picking Robot Arm Trajectory Planning Method

    Directory of Open Access Journals (Sweden)

    Zhang Zhiyong

    2014-01-01

    Full Text Available The picking robot arm is scheduled to complete picking tasks in the working space, to overcome the shaking vibration to improve the picking stability, its movement should follow specific consistence trajectory points. Usually we should give definite multiple feature picking points, map their inverse kinematics to the joint space, establish motion equation for the corresponding point in the joint space, then follow these equations motion for the interpolation on the joint so that we can meet the movement requirements. Trajectory planning is decisive significance for accuracy and stability of controlling robot arm. The key issue that picking arm complete picking task will be come true by trajectory planning, namely, robot arm track the desired trajectory. which based on kinematics and statics picking analysis in a joint space according to the requirements of picking tasks, and obtain the position and orientation for picking robot arm, study and calculate the theory of trajectory parameters timely.

  18. Arm locking with Doppler estimation errors

    Energy Technology Data Exchange (ETDEWEB)

    Yu Yinan; Wand, Vinzenz; Mitryk, Shawn; Mueller, Guido, E-mail: yinan@phys.ufl.ed [Department of Physics, University of Florida, Gainesville, FL 32611 (United States)

    2010-05-01

    At the University of Florida we developed the University of Florida LISA Interferometer Simulator (UFLIS) in order to study LISA interferometry with hardware in the loop at a system level. One of the proposed laser frequency stabilization techniques in LISA is arm locking. Arm locking uses an adequately filtered linear combination of the LISA arm signals as a frequency reference. We will report about experiments in which we demonstrated arm locking using UFLIS. During these experiments we also discovered a problem associated with the Doppler shift of the return beam. The initial arm locking publications assumed that this Doppler shift can perfectly be subtracted inside the phasemeter or adds an insignificant offset to the sensor signal. However, the remaining Doppler knowledge error will cause a constant change in the laser frequency if unaccounted for. Several ways to circumvent this problem have been identified. We performed detailed simulations and started preliminary experiments to verify the performance of the proposed new controller designs.

  19. Supporting the President's Arms Control and Nonproliferation Agenda: Transparency and Verification for Nuclear Arms Reductions

    International Nuclear Information System (INIS)

    Doyle, James E.; Meek, Elizabeth

    2009-01-01

    The President's arms control and nonproliferation agenda is still evolving and the details of initiatives supporting it remain undefined. This means that DOE, NNSA, NA-20, NA-24 and the national laboratories can help define the agenda, and the policies and the initiatives to support it. This will require effective internal and interagency coordination. The arms control and nonproliferation agenda is broad and includes the path-breaking goal of creating conditions for the elimination of nuclear weapons. Responsibility for various elements of the agenda will be widely scattered across the interagency. Therefore an interagency mapping exercise should be performed to identify the key points of engagement within NNSA and other agencies for creating effective policy coordination mechanisms. These can include informal networks, working groups, coordinating committees, interagency task forces, etc. It will be important for NA-20 and NA-24 to get a seat at the table and a functional role in many of these coordinating bodies. The arms control and nonproliferation agenda comprises both mature and developing policy initiatives. The more mature elements such as CTBT ratification and a follow-on strategic nuclear arms treaty with Russia have defined milestones. However, recent press reports indicate that even the START follow-on strategic arms pact that is planned to be complete by the end of 2009 may take significantly longer and be more expansive in scope. The Russians called for proposals to count non-deployed as well as deployed warheads. Other elements of the agenda such as FMCT, future bilateral nuclear arms reductions following a START follow-on treaty, nuclear posture changes, preparations for an international nuclear security summit, strengthened international safeguards and multilateral verification are in much earlier stages of development. For this reason any survey of arms control capabilities within the USG should be structured to address potential needs across the

  20. Simulation of Octopus Arm Based on Coupled CPGs

    Directory of Open Access Journals (Sweden)

    Juan Tian

    2015-01-01

    Full Text Available The octopus arm has attracted many researchers’ interests and became a research hot spot because of its amazing features. Several dynamic models inspired by an octopus arm are presented to realize the structure with a large number of degrees of freedom. The octopus arm is made of a soft material introducing high-dimensionality, nonlinearity, and elasticity, which makes the octopus arm difficult to control. In this paper, three coupled central pattern generators (CPGs are built and a 2-dimensional dynamic model of the octopus arm is presented to explore possible strategies of the octopus movement control. And the CPGs’ signals treated as activation are added on the ventral, dorsal, and transversal sides, respectively. The effects of the octopus arm are discussed when the parameters of the CPGs are changed. Simulations show that the octopus arm movements are mainly determined by the shapes of three CPGs’ phase diagrams. Therefore, some locomotion modes are supposed to be embedded in the neuromuscular system of the octopus arm. And the octopus arm movements can be achieved by modulating the parameters of the CPGs. The results are beneficial for researchers to understand the octopus movement further.

  1. Arm-to-arm variation when evaluating neuromuscular block: an analysis of the precision and the bias and agreement between arms when using mechanomyography or acceleromyography

    DEFF Research Database (Denmark)

    Claudius, C; Skovgaard, L T; Viby-Mogensen, J

    2010-01-01

    Studies comparing acceleromyography and mechanomyography indicate that the two methods cannot be used interchangeably. However, it is uncertain to what extent differences in precision between the methods and the naturally occurring arm-to-arm variation have influenced the results of these studies...

  2. Control of a virtual ambulation influences body movement and motion sickness

    Directory of Open Access Journals (Sweden)

    Hagstrom Jens

    2011-12-01

    Full Text Available Drivers typically are less susceptible to motion sickness than passengers. The influence of vehicle control has theoretical implications for the etiology of motion sickness, and has practical implications for the design of virtual environments. In the present study, participants either controlled or did not control a nonvehicular virtual avatar (i.e., an ambulatory character in a console video game. We examined the incidence of motion sickness and patterns of movement of the head and torso as participants either played or watched the game. Motion sickness incidence was lower when controlling the virutal avatar than when watching an avatar that was controlled by someone else. Patterns of head and torso movement differed between particpants who did and did not control the avatar. Indepenently, patterns of movement differed between participants who reported motion sickness and those who did not. The results suggest that motion sickness is influenced by control of stimulus motion, whether that motion arises from a vehicle or from any other source. We consider implications for the design of humancomputer interfaces.

  3. Motion control, motion sickness, and the postural dynamics of mobile devices.

    Science.gov (United States)

    Stoffregen, Thomas A; Chen, Yi-Chou; Koslucher, Frank C

    2014-04-01

    Drivers are less likely than passengers to experience motion sickness, an effect that is important for any theoretical account of motion sickness etiology. We asked whether different types of control would affect the incidence of motion sickness, and whether any such effects would be related to participants' control of their own bodies. Participants played a video game on a tablet computer. In the Touch condition, the device was stationary and participants controlled the game exclusively through fingertip inputs via the device's touch screen. In the Tilt condition, participants held the device in their hands and moved the device to control some game functions. Results revealed that the incidence of motion sickness was greater in the Touch condition than in the Tilt condition. During game play, movement of the head and torso differed as a function of the type of game control. Before the onset of subjective symptoms of motion sickness, movement of the head and torso differed between participants who later reported motion sickness and those that did not. We discuss implications of these results for theories of motion sickness etiology.

  4. Broken Arm

    Science.gov (United States)

    ... of falling — including football, soccer, gymnastics, skiing and skateboarding — also increases the risk of a broken arm. ... for high-risk activities, such as in-line skating, snowboarding, rugby and football. Don't smoke. Smoking ...

  5. 49 CFR 236.810 - Spectacle, semaphore arm.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Spectacle, semaphore arm. 236.810 Section 236.810 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Spectacle, semaphore arm. That part of a semaphore arm which holds the roundels and to which the blade is...

  6. Kinematics of the AM-50 heading machine cutting head

    Energy Technology Data Exchange (ETDEWEB)

    Sikora, W; Bak, K; Klich, R [Politechnika Slaska, Gliwice (Poland). Instytut Mechanizacji Gornictwa

    1987-01-01

    Analyzes motion of the cutter head of the AM-50 heading machine. Two types of head motion are comparatively evaluated: planar motion and spatial motion. The spatial motion consists of the head rotational motion and horizontal or vertical feed motion, while planar motion consists of rotational motion and vertical feed motion. Equations that describe head motion under conditions of cutter vertical or horizontal feed motion are derived. The angle between the cutting speed direction and working speed direction is defined. On the basis of these formulae variations of cutting speed depending on the cutting tool position on a cutter head are calculated. Calculations made for 2 extreme cutting tools show that the cutting speed ranges from 1,205 m/s to 3,512 m/s. 4 refs.

  7. Arming shoes of the fifteenth century

    OpenAIRE

    Volken Marquita

    2017-01-01

    Military footwear for the fifteenth century includes arming shoes worn under sabatons. Written sources suggest arming shoes and footwear used for fighting were ordinary shoes adapted for the purpose. Archaeological footwear was examined for signs of such modifications. Medieval shoe technology is presented, showing the range of footwear and its uses and gait biomechanics. Based on experiences from re-enactors wearing armours, medieval shoe styles are discussed for appropriateness as arming sh...

  8. Concurrent validity and reliability of torso-worn inertial measurement unit for jump power and height estimation.

    Science.gov (United States)

    Rantalainen, Timo; Gastin, Paul B; Spangler, Rhys; Wundersitz, Daniel

    2018-09-01

    The purpose of the present study was to evaluate the concurrent validity and test-retest repeatability of torso-worn IMU-derived power and jump height in a counter-movement jump test. Twenty-seven healthy recreationally active males (age, 21.9 [SD 2.0] y, height, 1.76 [0.7] m, mass, 73.7 [10.3] kg) wore an IMU and completed three counter-movement jumps a week apart. A force platform and a 3D motion analysis system were used to concurrently measure the jumps and subsequently derive power and jump height (based on take-off velocity and flight time). The IMU significantly overestimated power (mean difference = 7.3 W/kg; P jump heights exhibited poorer concurrent validity (ICC = 0.72 to 0.78) and repeatability (ICC = 0.68) than flight-time-derived jump heights, which exhibited excellent validity (ICC = 0.93 to 0.96) and reliability (ICC = 0.91). Since jump height and power are closely related, and flight-time-derived jump height exhibits excellent concurrent validity and reliability, flight-time-derived jump height could provide a more desirable measure compared to power when assessing athletic performance in a counter-movement jump with IMUs.

  9. International security and arms control

    International Nuclear Information System (INIS)

    Ekeus, R.

    2000-01-01

    The end of the cold war also ended the focus on the bilateral approach to arms control and disarmament. Key concepts of security needed to be revisited, along with their implications for the disarmament and arms control agenda. Though there is currently a unipolar global security environment, there remain important tasks on the multilateral arms control agenda. The major task is that of reducing and eliminating weapons of mass destruction, especially nuclear weapons. The author contends that maintaining reliance on the nuclear-weapons option makes little sense in a time when the major Powers are strengthening their partnerships in economics, trade, peacemaking and building. (author)

  10. Wound Ballistics Modeling for Blast Loading Blunt Force Impact and Projectile Penetration

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, Paul A. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Cooper, Candice Frances [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Burnett, Damon J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-09-01

    Light body armor development for the warfighter is based on trial-and-error testing of prototype designs against ballistic projectiles. Torso armor testing against blast is virtually nonexistent but necessary to ensure adequate protection against injury to the heart and lungs. In this report, we discuss the development of a high-fidelity human torso model, it's merging with the existing Sandia Human Head-Neck Model, and development of the modeling & simulation (M&S) capabilities necessary to simulate wound injury scenarios. Using the new Sandia Human Torso Model, we demonstrate the advantage of virtual simulation in the investigation of wound injury as it relates to the warfighter experience. We present the results of virtual simulations of blast loading and ballistic projectile impact to the tors o with and without notional protective armor. In this manner, we demonstrate the ad vantages of applying a modeling and simulation approach to the investigation of wound injury and relative merit assessments of protective body armor without the need for trial-and-error testing.

  11. Preventing Interstate Armed Conflict : whose responsibility?

    OpenAIRE

    Otunba, Ganiyu

    2010-01-01

    This is a study of interstate armed conflict prevention. The concept of conflict, armed conflict and conflict prevention is defined and explained in order to be able to investigate if there is any single institution saddled with the responsibility of preventing interstate armed conflict and also to verify if adequate efforts are been put in this area which is of importance to mankind. The relationship between conflict prevention, conflict management and conflict resolution is also discussed s...

  12. Strategic arms limitation

    Science.gov (United States)

    Allen Greb, G.; Johnson, Gerald W.

    1983-10-01

    Following World War II, American scientists and politicians proposed in the Baruch plan a radical solution to the problem of nuclear weapons: to eliminate them forever under the auspices of an international nuclear development authority. The Soviets, who as yet did not possess the bomb, rejected this plan. Another approach suggested by Secretary of War Henry Stimson to negotiate directly with the Soviet Union was not accepted by the American leadership. These initial arms limitation failures both reflected and exacerbated the hostile political relationship of the superpowers in the 1950s and 1960s. Since 1969, the more modest focus of the Soviet-American arms control process has been on limiting the numbers and sizes of both defensive and offensive strategic systems. The format for this effort has been the Strategic Arms Limitatins Talks (Salt) and more recently the Strategic Arms Reduction Talks (START). Both sides came to these negotiations convinced that nuclear arsenals had grown so large that some for of mutual restraint was needed. Although the SALT/START process has been slow and ponderous, it has produced several concrete the agreements and collateral benefits. The 1972 ABM Treaty restricts the deployment of ballistic missile defense systems, the 1972 Interim Agreement places a quantitative freeze on each side's land based and sea based strategic launchers, and the as yet unratified 1979 SALT II Treaty sets numerical limits on all offensive strategic systems and sublimits on MIRVed systems. Collateral benefits include improved verification procedures, working definitions and counting rules, and permanent bureaucratic apparatus which enhance stability and increase the chances for achieving additional agreements.

  13. Planet-driven Spiral Arms in Protoplanetary Disks. II. Implications

    Science.gov (United States)

    Bae, Jaehan; Zhu, Zhaohuan

    2018-06-01

    We examine whether various characteristics of planet-driven spiral arms can be used to constrain the masses of unseen planets and their positions within their disks. By carrying out two-dimensional hydrodynamic simulations varying planet mass and disk gas temperature, we find that a larger number of spiral arms form with a smaller planet mass and a lower disk temperature. A planet excites two or more spiral arms interior to its orbit for a range of disk temperatures characterized by the disk aspect ratio 0.04≤slant {(h/r)}p≤slant 0.15, whereas exterior to a planet’s orbit multiple spiral arms can form only in cold disks with {(h/r)}p≲ 0.06. Constraining the planet mass with the pitch angle of spiral arms requires accurate disk temperature measurements that might be challenging even with ALMA. However, the property that the pitch angle of planet-driven spiral arms decreases away from the planet can be a powerful diagnostic to determine whether the planet is located interior or exterior to the observed spirals. The arm-to-arm separations increase as a function of planet mass, consistent with previous studies; however, the exact slope depends on disk temperature as well as the radial location where the arm-to-arm separations are measured. We apply these diagnostics to the spiral arms seen in MWC 758 and Elias 2–27. As shown in Bae et al., planet-driven spiral arms can create concentric rings and gaps, which can produce a more dominant observable signature than spiral arms under certain circumstances. We discuss the observability of planet-driven spiral arms versus rings and gaps.

  14. Repositioning accuracy: Comparison of a noninvasive head holder with thermoplastic mask for fractionated radiotherapy and a case report

    International Nuclear Information System (INIS)

    Sweeney, Reinhart; Bale, Reto; Vogele, Michael; Nevinny-Stickel, Meinhart; Bluhm, Anja; Auer, Thomas; Hessenberger, Gerhart; Lukas, Peter

    1998-01-01

    Purpose: To compare accuracy, clinical feasibility, and subjective patient impression between a noninvasive head holder (Vogele Bale Hohner [VBH]; Wellhoefer Dosimetry, Schwarzenbruck, Germany) developed at the University of Innsbruck and the thermoplastic mask fixation system for use in fractionated external radiotherapy. We present a case report of an actual patient fixated in the VBH head holder during radiation therapy. Materials and Methods: The VBH head holder consists of an individualized vacuum dental cast connected to a head plate via two hydraulic arms allowing noninvasive, reproducible head fixation of even uncooperative patients. Accuracy was tested and compared with that of the thermoplastic mask using the Phillips EasyGuide navigation system on five volunteers. Specific external registration points served as landmarks and their positions were compared after each repositioning. System and operator inaccuracy were also taken into account. The times taken for production and repositioning of the respective fixation devices were compared, and subjective impressions were noted. Results: Mean VBH head holder repositioning accuracy was 1.02 mm while that of the thermoplastic mask was 3.05 mm. 69% of mask repositionings showed a deviation > 2 mm and 41% > 3 mm (as opposed to 8% and 1% respectively for the VBH head holder) Those points located farthest away from the respective plane of fixation showed the largest deviations. Both production and repositioning times were similar between the systems; depending upon the patient, the VBH head holder was generally better tolerated than the mask system. Conclusion: Due to its significantly better repositioning accuracy compared to that of the thermoplastic mask, the VBH head holder is especially suited for external radiation requiring precise repositioning due to critical tissues in immediate surrounding of the area to be irradiated

  15. Mechanical characterization of the Varian Exact-arm and R-arm support systems for eight aS500 electronic portal imaging devices

    International Nuclear Information System (INIS)

    Grattan, Mark W. D.; McGarry, Conor K.

    2010-01-01

    Purpose: The aim of this study is to compare the positioning accuracy at different gantry angles of two electronic portal imaging devices (EPIDs) support arm systems by using EPID difference images as a measure for displacement. This work presents a comparison of the mechanical performance of eight Varian aS500 (Varian Medical Systems, Palo Alto, CA) EPIDs, mounted using either the Varian Exact-arm or R-arm. Methods: The mechanical performance of the two arm systems was compared by investigating the variation in sensitivity with gantry angle, both before and after the EPID position was adjusted after gantry rotation. Positional errors were investigated by subtracting images from a reference image taken at gantry 0 deg., and the amplitude of the peaks and troughs at the field edges for longitudinal (radial) and lateral (transverse) profiles across the resulting image was related to the distance of displacement. Calibration curves based on a pixel-by-pixel shift were generated for each EPID and the Varian hand pendant accuracy was compared to the calibration data. Results: The response of the EPIDs was found to change with gantry rotation, with the largest difference at 180 deg. The Exact-arm was found to correct well for any displacement, while the R-arm tended to overcorrect following repositioning using the hand pendant. The calibration curves were consistent within each set of matched linacs, and the hand pendant accuracy was similar for both arm systems, although generally in different directions. With respect to gantry rotation effects, the mechanical performance of the Exact-arm systems was found to be much better than that of the R-arm systems. At gantry positions 90 deg., 270 deg., and 180 deg. the average misalignment in the longitudinal direction was +4.2±0.2, +1.8±1.6, and +7.4±0.5 mm for the R-arms, and +2.9±0.2, +2.1±0.8, and +4.9±0.7 mm for the Exact-arms. In the lateral direction the average positional errors were +2.1±0.4, -4.7±0.4, and -2.5

  16. Controlling robot arm with the mind

    National Science Foundation

    2017-05-31

    Full Text Available Research test subjects at the University of Minnesota who were fitted with a specialized noninvasive brain cap were able to move a robotic arm just by imagining moving their own arms.

  17. Limited consensus around ARM information protection practices ...

    African Journals Online (AJOL)

    An existing enterprise IP SoP was adapted to ARM through literature analysis and produced a draft ARM SoP. The draft ARM SoP was applied in a rote fashion to a small sample of government-operated archives to identify likely areas of consensus and lack of consensus surrounding the various elements of the SoP.

  18. Arms Races and Negotiations

    OpenAIRE

    Sandeep Baliga; Tomas Sjostrom

    2003-01-01

    Two players simultaneously decide whether or not to acquire new weapons in an arms race game. Each player's type determines his propensity to arm. Types are private information, and are independently drawn from a continuous distribution. With probability close to one, the best outcome for each player is for neither to acquire new weapons (although each prefers to acquire new weapons if he thinks the opponent will). There is a small probability that a player is a dominant strategy type who alw...

  19. Comparative genomic hybridization analysis detects frequent over-representation of DNA sequences at 3q, 7p, 8q and 18q in head and neck carcinomas

    DEFF Research Database (Denmark)

    Bergamo, N A; Rogatto, S R; Poli-Frederico, R C

    2000-01-01

    Comparative genomic hybridization (CGH) was used to identify chromosomal imbalances in 19 samples of squamous cell carcinoma of the head and neck (HNSCC). The chromosome arms most often over-represented were 3q (48%), 8q (42%), and 7p (32%); in many cases, these changes were observed at high copy...... and 2q material were detected in patients exhibiting a clinical history of recurrence and/or metastasis followed by terminal disease. This association suggests that gain of 1q and 2q may be a new marker of head and neck tumors with a refractory clinical response....

  20. Rolling motions in an inner spiral arm

    International Nuclear Information System (INIS)

    Strauss, F.M.; Poeppel, W.

    1976-01-01

    Hydrogen line observations made at low galactic latitudes for l=318degree, 326degree, 334degree, and 337degree show the presence of velocity gradients in latitude in the nearest inner spiral arm, similar to those found by other observations in different regions. Maximum velocity change is about 10 km s -1 for l=337degree. By generating synthetic line profiles constructed from a model spiral arm, several possible causes of these ''rolling motions'' were studied, such as a vertical displacement or a tilt of the arm (which failed to account for the observations) and rotation or shearing in the arm. It was futher shown that a typical arm can maintain such a motion (approx. =75 km s -1 kpc -1 ) with its own gravitational potential. The results are used to study the origin and tilt of Gould's Belt

  1. Dosimetry audit for a multi-centre IMRT head and neck trial

    International Nuclear Information System (INIS)

    Clark, Catharine H.; Hansen, Vibeke Nordmark; Chantler, Hannah; Edwards, Craig; James, Hayley V.; Webster, Gareth; Miles, Elizabeth A.; Guerrero Urbano, M. Teresa; Bhide, Shree A.; Bidmead, A. Margaret; Nutting, Christoper M.

    2009-01-01

    Background and purpose: PARSPORT was a multi-centre randomised trial in the UK which compared Intensity-Modulated Radiotherapy (IMRT) and conventional radiotherapy (CRT) for patients with head and neck cancer. The dosimetry audit goals were to verify the plan delivery in participating centres, ascertain what tolerances were suitable for head and neck IMRT trials and develop an IMRT credentialing program. Materials and methods: Centres enrolling patients underwent rigorous quality assurance before joining the trial. Following this each centre was visited for a dosimetry audit, which consisted of treatment planning system tests, fluence verification films, combined field films and dose point measurements. Results: Mean dose point measurements were made at six centres. For the primary planning target volume (PTV) the differences with the planned values for the IMRT and CRT arms were -0.6% (1.8% to -2.4%) and 0.7% (2.0% to -0.9%), respectively. Ninety-four percent of the IMRT fluence films for individual fields passed gamma criterion of 3%/3 mm and 75% of the films for combined fields passed gamma criterion 4%/3 mm (no significant difference between dynamic delivery and step and shoot delivery). Conclusions: This audit suggests that a 3% tolerance could be applied for PTV point doses. For dose distributions tolerances of 3%/3 mm on individual fields and 4%/3 mm for combined fields are proposed for multi-centre head and neck IMRT trials.

  2. Evaluation of imaging quality for flat-panel detector based low dose C-arm CT system

    International Nuclear Information System (INIS)

    Seo, Chang-Woo; Cha, Bo Kyung; Jeon, Sungchae; Huh, Young

    2015-01-01

    The image quality associated with the extent of the angle of gantry rotation, the number of projection views, and the dose of X-ray radiation was investigated in flat-panel detector (FPD) based C-arm cone-beam computed tomography (CBCT) system for medical applications. A prototype CBCT system for the projection acquisition used the X-ray tube (A-132, Varian inc.) having rhenium-tungsten molybdenum target and flat panel a-Si X-ray detector (PaxScan 4030CB, Varian inc.) having a 397 x 298 mm active area with 388 μm pixel pitch and 1024 x 768 pixels in 2 by 2 binning mode. The performance comparison of X-ray imaging quality was carried out using the Feldkamp, Davis, and Kress (FDK) reconstruction algorithm between different conditions of projection acquisition. In this work, head-and-dental (75 kVp/20 mA) and chest (90 kVp/25 mA) phantoms were used to evaluate the image quality. The 361 (30 fps x 12 s) projection data during 360 deg. gantry rotation with 1 deg. interval for the 3D reconstruction were acquired. Parke weighting function were applied to handle redundant data and improve the reconstructed image quality in a mobile C-arm system with limited rotation angles. The reconstructed 3D images were investigated for comparison of qualitative image quality in terms of scan protocols (projection views, rotation angles and exposure dose). Furthermore, the performance evaluation in image quality will be investigated regarding X-ray dose and limited projection data for a FPD based mobile C-arm CBCT system. (authors)

  3. Evaluation of pediatric ATD biofidelity as compared to child volunteers in low-speed far-side oblique and lateral impacts.

    Science.gov (United States)

    Seacrist, Thomas; Locey, Caitlin M; Mathews, Emily A; Jones, Dakota L; Balasubramanian, Sriram; Maltese, Matthew R; Arbogast, Kristy B

    2014-01-01

    Motor vehicle crashes are a leading cause of injury and mortality for children. Mitigation of these injuries requires biofidelic anthropomorphic test devices (ATDs) to design and evaluate automotive safety systems. Effective countermeasures exist for frontal and near-side impacts but are limited for far-side impacts. Consequently, far-side impacts represent increased injury and mortality rates compared to frontal impacts. Thus, the objective of this study was to evaluate the biofidelity of the Hybrid III and Q-series pediatric ATDs in low-speed far-side impacts, with and without shoulder belt pretightening. Low-speed (2 g) far-side oblique (60°) and lateral (90°) sled tests were conducted using the Hybrid III and Q-series 6- and 10-year-old ATDs. ATDs were restrained by a lap and shoulder belt equipped with a precrash belt pretightener. Photoreflective targets were attached to the head, spine, shoulders, and sternum. ATDs were exposed to 8 low-speed sled tests: 2 oblique nontightened, 2 oblique pretightened, 2 lateral nontightened, 2 lateral pretightened. ATDs were compared with previously collected 9- to 11-year-old (n=10) volunteer data and newly collected 6- to 8-year-old volunteer data (n=7) tested with similar methods. Kinematic data were collected from a 3D target tracking system. Metrics of comparison included excursion, seat belt and seat pan reaction loads, belt-to-torso angle, and shoulder belt slip-out. The ATDs exhibited increased lateral excursion of the head top, C4, and T1 as well as increased downward excursion of the head top compared to the volunteers. Volunteers exhibited greater forward excursion than the ATDs in oblique nontightened impacts. These kinematics correspond to increased shoulder belt slip-out for the ATDs in oblique tests (ATDs=90%; volunteers=36%). Contrarily, similar shoulder belt slip-out was observed between ATDs and volunteers in lateral impacts (ATDs=80%; volunteers=78%). In pretightened impacts, the ATDs exhibited reduced

  4. Gender differences in head-neck segment dynamic stabilization during head acceleration.

    Science.gov (United States)

    Tierney, Ryan T; Sitler, Michael R; Swanik, C Buz; Swanik, Kathleen A; Higgins, Michael; Torg, Joseph

    2005-02-01

    Recent epidemiological research has revealed that gender differences exist in concussion incidence but no study has investigated why females may be at greater risk of concussion. Our purpose was to determine whether gender differences existed in head-neck segment kinematic and neuromuscular control variables responses to an external force application with and without neck muscle preactivation. Forty (20 females and 20 males) physically active volunteers participated in the study. The independent variables were gender, force application (known vs unknown), and force direction (forced flexion vs forced extension). The dependent variables were kinematic and EMG variables, head-neck segment stiffness, and head-neck segment flexor and extensor isometric strength. Statistical analyses consisted of multiple multivariate and univariate analyses of variance, follow-up univariate analyses of variance, and t-tests (P Gender differences existed in head-neck segment dynamic stabilization during head angular acceleration. Females exhibited significantly greater head-neck segment peak angular acceleration (50%) and displacement (39%) than males despite initiating muscle activity significantly earlier (SCM only) and using a greater percentage of their maximum head-neck segment muscle activity (79% peak activity and 117% muscle activity area). The head-neck segment angular acceleration differences may be because females exhibited significantly less isometric strength (49%), neck girth (30%), and head mass (43%), resulting in lower levels of head-neck segment stiffness (29%). For our subject demographic, the results revealed gender differences in head-neck segment dynamic stabilization during head acceleration in response to an external force application. Females exhibited significantly greater head-neck segment peak angular acceleration and displacement than males despite initiating muscle activity earlier (SCM only) and using a greater percentage of their maximum head-neck segment

  5. NRS-2002 for pre-treatment nutritional risk screening and nutritional status assessment in head and neck cancer patients.

    Science.gov (United States)

    Orell-Kotikangas, Helena; Österlund, Pia; Saarilahti, Kauko; Ravasco, Paula; Schwab, Ursula; Mäkitie, Antti A

    2015-06-01

    The aim of this study was to assess the value of nutritional risk screening-2002 (NRS-2002) as a nutritional risk screening and status assessment method and to compare it with nutritional status assessed by subjective and objective methods in the screening of head and neck cancer patients. Sixty-five consecutive patients (50 male), with a median age of 61 years (range, 33-77), with head and neck squamous cell carcinoma (HNSCC) were enrolled prior to cancer therapy. Nutritional status was assessed by NRS-2002, patient-generated subjective global assessment (PG-SGA), handgrip strength (HGS) and mid-arm muscle area (MAMA). Twenty-eight percent of patients were at nutritional risk based on NRS-2002, and 34 % were malnourished according to PG-SGA, while 43 % had low HGS. NRS-2002 cut-off score of ≥3 compared with the nutritional status according to PG-SGA showed 77 % specificity and 98 % sensitivity (K = 0.78). NRS-2002 was able to predict malnutrition (PG-SGA BC) both in men (p nutrition screening in head and neck cancer patients prior to oncological treatment.

  6. Arming shoes of the fifteenth century

    Directory of Open Access Journals (Sweden)

    Volken Marquita

    2017-12-01

    Full Text Available Military footwear for the fifteenth century includes arming shoes worn under sabatons. Written sources suggest arming shoes and footwear used for fighting were ordinary shoes adapted for the purpose. Archaeological footwear was examined for signs of such modifications. Medieval shoe technology is presented, showing the range of footwear and its uses and gait biomechanics. Based on experiences from re-enactors wearing armours, medieval shoe styles are discussed for appropriateness as arming shoes. The question of why medieval military footwear shows no purposed development is addressed.

  7. An environmental overview of the Cat Arm hydroelectric development

    International Nuclear Information System (INIS)

    Barnes, J.L.

    1987-01-01

    The Cat Arm Dam hydroelectric development in Newfoundland comprises 10 dams, three tunnels, two canals and a 127 MW powerhouse. The scheme develops 127 MW from 380.5 m of head and comprises: ten dams of varying heights up to 53 m; a bathtub type overflow spillway 330 m in length; a 230 m long inverted U-shaped diversion tunnel; an 800 m long, inverted U-shaped low pressure forebay tunnel; two bog and rock cut tunnels leading to and from the forebay tunnels; a surface powerhouse containing two Pelton turbines; and a 178 km long, 230 kV transmission line. An overview is provided of the environmental assessment, project impacts, and cost of environmental protection associated with the project. Impacts were centered around fish and aquatic life in the created reservoir and downstream of the powerhouse, loss of ungulate (moose and caribou) habitat due to flooding, loss of forestry resources due to flooding, and the disturbance of land during construction. The overall cost of environmental protection was $7,977,000, only 2% of the total project cost. 17 refs., 1 tab

  8. Level of Agreement Between Forearm and Upper Arm Blood Pressure Measurements in Patients With Large Arm Circumference.

    Science.gov (United States)

    Watson, Sheri; Aguas, Marita; Colegrove, Pat; Foisy, Nancy; Jondahl, Bonnie; Anastas, Zoe

    2017-02-01

    The purpose of the study was to determine if forearm blood pressures (BPs) measured in three different locations agree with the recommended upper arm location for noninvasive BP measurement. A method-comparison design was used. In a convenience sample of postanesthesia care unit patients with large upper arm circumference, BP's were obtained in three different forearm locations (lower forearm, middle forearm, and upper forearm) and compared to upper arm BP using an automated BP measuring device. The level of agreement (bias ± precision) between each forearm location and the upper arm BP was calculated using standard formulas. Acceptable levels of agreement based on expert opinion were set a priori at bias and precision values of less than ±5 mm Hg (bias) and ±8 mm Hg (precision). Forty-eight postanesthesia patients participated in the study. Bias and precision values were found to exceed the acceptable level of agreement for all but one of the systolic and diastolic BP comparisons in the three forearm BP locations. Fifty-six percent of all patients studied had one or more BP difference of at least 10 mm Hg in each of the three forearm locations, with 10% having one or more differences of at least 20 mm Hg. The differences in forearm BP measurements observed in this study indicate that the clinical practice of using a forearm BP with a regular-sized BP cuff in place of a larger sized BP cuff placed on the upper arm in postanesthesia care unit patients with large arm circumferences is inappropriate. The BPs obtained at the forearm location are not equivalent to the BPs obtained at the upper arm location. Copyright © 2015 American Society of PeriAnesthesia Nurses. Published by Elsevier Inc. All rights reserved.

  9. Simulation of Octopus Arm Based on Coupled CPGs

    OpenAIRE

    Juan Tian; Qiang Lu

    2015-01-01

    The octopus arm has attracted many researchers’ interests and became a research hot spot because of its amazing features. Several dynamic models inspired by an octopus arm are presented to realize the structure with a large number of degrees of freedom. The octopus arm is made of a soft material introducing high-dimensionality, nonlinearity, and elasticity, which makes the octopus arm difficult to control. In this paper, three coupled central pattern generators (CPGs) are built and a 2-dimens...

  10. Kinematic decomposition and classification of octopus arm movements

    OpenAIRE

    Zelman, Ido; Titon, Myriam; Yekutieli, Yoram; Hanassy, Shlomi; Hochner, Binyamin; Flash, Tamar

    2013-01-01

    The octopus arm is a muscular hydrostat and due to its deformable and highly flexible structure it is capable of a rich repertoire of motor behaviors. Its motor control system uses planning principles and control strategies unique to muscular hydrostats. We previously reconstructed a data set of octopus arm movements from records of natural movements using a sequence of 3D curves describing the virtual backbone of arm configurations. Here we describe a novel representation of octopus arm move...

  11. The inter-arm diastolic blood pressure difference induced by one arm ischemia: a new approach to assess vascular endothelia function.

    Science.gov (United States)

    Hu, Weitong; Li, Juxiang; Su, Hai; Wang, Jiwei; Xu, Jinsong; Liu, Yanna; Huang, Ming; Cheng, Xiaoshu

    2014-01-01

    To evaluate whether inter-arm diastolic blood pressure difference (DBPl-r) induced by one arm ischemia correlates with flow-mediated dilatation (FMD). Bilateral arm BPs were simultaneously measured with two automatic devices and right brachial artery diameter (D) was measured by ultrasound technique in 108 subjects (56 hypertensives and 52 normotensives). Following baseline diameter (D0) and BP measurement, right brachial artery was occluded for 5 minutes. The diameter was measured at 1, 1.5 and 2 min, and bilateral BPs measured at 3, 4 and 5 min after occlusion release. Their averages were recorded as post-D and post-BP, respectively. The difference between post-D and D0 (ΔD) was calculated as the percentage increase of artery diameter (ΔD/D0). The BP difference between left and right arms was calculated as BPl-r, and the difference of post- BPl-r and baseline BPl-r was recorded as the net change of BPl-r (ΔBPl-r). At baseline, bilateral SBPs and DBPs were similar. Right arm ischemia induced significant DBP decline only in the right arm (68.8±12.7 vs 72.6±12.0 mmHg, Parm DBP difference induced by one arm ischemia may be a potential index for clinical evaluation of vascular endothelial function.

  12. Robust coordinated control of a dual-arm space robot

    Science.gov (United States)

    Shi, Lingling; Kayastha, Sharmila; Katupitiya, Jay

    2017-09-01

    Dual-arm space robots are more capable of implementing complex space tasks compared with single arm space robots. However, the dynamic coupling between the arms and the base will have a serious impact on the spacecraft attitude and the hand motion of each arm. Instead of considering one arm as the mission arm and the other as the balance arm, in this work two arms of the space robot perform as mission arms aimed at accomplishing secure capture of a floating target. The paper investigates coordinated control of the base's attitude and the arms' motion in the task space in the presence of system uncertainties. Two types of controllers, i.e. a Sliding Mode Controller (SMC) and a nonlinear Model Predictive Controller (MPC) are verified and compared with a conventional Computed-Torque Controller (CTC) through numerical simulations in terms of control accuracy and system robustness. Both controllers eliminate the need to linearly parameterize the dynamic equations. The MPC has been shown to achieve performance with higher accuracy than CTC and SMC in the absence of system uncertainties under the condition that they consume comparable energy. When the system uncertainties are included, SMC and CTC present advantageous robustness than MPC. Specifically, in a case where system inertia increases, SMC delivers higher accuracy than CTC and costs the least amount of energy.

  13. Bilateral movements increase sustained extensor force in the paretic arm.

    Science.gov (United States)

    Kang, Nyeonju; Cauraugh, James H

    2018-04-01

    Muscle weakness in the extensors poststroke is a common motor impairment. Unfortunately, research is unclear on whether bilateral movements increase extensor force production in the paretic arm. This study investigated sustained force production while stroke individuals maximally extended their wrist and fingers on their paretic arm. Specifically, we determined isometric force production in three conditions: (a) unilateral paretic arm, (b) unilateral nonparetic arm, and (c) bilateral (both arms executing the same movement simultaneously). Seventeen chronic stroke patients produced isometric sustained force by executing wrist and fingers extension in unilateral and bilateral contraction conditions. Mean force, force variability (coefficient of variation), and signal-to-noise ratio were calculated for each contraction condition. Analysis of two-way (Arm × Type of Condition: 2 × 2; Paretic or Nonparetic Arm × Unilateral or Bilateral Conditions) within-subjects ANOVAs revealed that the bilateral condition increased sustained force in the paretic arm, but reduced sustained force in the nonparetic arm. Further, although the paretic arm exhibited more force variability and less signal-to-noise ratio than the nonparetic arm during a unilateral condition, there were no differences when participants simultaneously executed isometric contractions with both arms. Our unique findings indicate that bilateral contractions transiently increased extensor force in the paretic arm. Implications for Rehabilitation Bilateral movements increased isometric wrsit extensor force in paretic arms and redcued force in nonparetic arms versus unilateral movements. Both paretic and nonparetic arms produced similar force variability and signal-to-noise ratio during bilateral movements. Increased sustained force in the paretic arm during the bilateral condition indicates that rehabilitation protocols based on bilateral movements may be beneficial for functional recovery.

  14. Prognostic significance of between-arm blood pressure differences.

    Science.gov (United States)

    Agarwal, Rajiv; Bunaye, Zerihun; Bekele, Dagim M

    2008-03-01

    Blood pressure (BP) recordings often differ between arms, but the extent to which these differences are reproducible and whether the differences have prognostic importance is unknown. We enrolled 421 consecutive patients from a medicine and a renal clinic at a veterans' hospital. Three BP recordings were obtained in each arm using an oscillometric device in a sequential manner and repeated in 1 week. Patients were followed for all-cause mortality arm had 5.1-mm Hg higher systolic BP that attenuated by approximately 2.2 mm Hg a week later. Systolic BP dropped 6.9 mm Hg over 1 week and by an additional 5.3 mm Hg in patients with chronic kidney disease. Accounting for the visit and arm effect improved the reproducibility of the BP measurements. The intraclass correlation coefficient was 0.74, which improved to 0.88 after accounting for visit and 0.93 after accounting for arm. The crude mortality rate was 6.33 per 100 patient-years. Every 10-mm Hg difference in systolic BP between the arms conferred a mortality hazard of 1.24 (95% CI: 1.01 to 1.52) after adjusting for average systolic BP and chronic kidney disease. BP differences between arms are reproducible and carry prognostic information. Patients should have evaluation of BP in both arms at the screening visit.

  15. Nuclear Arms Race and Environment

    OpenAIRE

    Li, Anpeng

    2012-01-01

    This paper introduces a new factor, environment, into nuclear arms race model. In this model, nuclear weapons produce larger defense power compared with conventional arms, but hurt the environment meanwhile. In the global welfare maximum level, both conventional and nuclear weapons budget are zero. However, the competitive equilibrium may not achieve the optimum. I give the condition to jump out of the prisoner's dilemma.

  16. Burial of a Man-At-Arms in Kudash I Burial Ground

    Directory of Open Access Journals (Sweden)

    Kazantseva Olga A.

    2017-07-01

    Full Text Available The article features a comprehensive analysis of items discovered in male burial 160 of Kudash I burial ground – a unique source of materials for the research of interactions between the local and foreign population on the Middle Kama region in 3rd – 5th centuries A.D. The monument is located in Bardymsky district of Perm Krai. The complex of metal objects comprises a set of personal protective armament rarely discovered in the Kama region: an open-work helmet, a set of plate armour, a sword, a spear head, a knife and "crooked scythes". The article contains a description of the grave, its structure, morphology and classification of findings, as well as the results of an investigation of the manufacturing technology of the following armament and implements: sword, spear head, knife, and "crooked scythe" conducted using the metallographic method. It also features a graphical reconstruction of the warriors’s protective armament – the helmet. The authors determined counterparts of the grave complex discovered at archaeological sites in the Middle Kama region and the Altai Mountains. The apparel of the man-at-arms represents a unique set of protective and offensive armament. The armour of the deceased is complemented by an open-work ceremonial helmet with an aventail, which suggests that the grave belonged to a military commander. The date of burial was determined on the basis of artefact study results as late 4th – early 5th centuries A.D.

  17. Planet-driven Spiral Arms in Protoplanetary Disks. I. Formation Mechanism

    Science.gov (United States)

    Bae, Jaehan; Zhu, Zhaohuan

    2018-06-01

    Protoplanetary disk simulations show that a single planet can excite more than one spiral arm, possibly explaining the recent observations of multiple spiral arms in some systems. In this paper, we explain the mechanism by which a planet excites multiple spiral arms in a protoplanetary disk. Contrary to previous speculations, the formation of both primary and additional arms can be understood as a linear process when the planet mass is sufficiently small. A planet resonantly interacts with epicyclic oscillations in the disk, launching spiral wave modes around the Lindblad resonances. When a set of wave modes is in phase, they can constructively interfere with each other and create a spiral arm. More than one spiral arm can form because such constructive interference can occur for different sets of wave modes, with the exact number and launching position of the spiral arms being dependent on the planet mass as well as the disk temperature profile. Nonlinear effects become increasingly important as the planet mass increases, resulting in spiral arms with stronger shocks and thus larger pitch angles. This is found to be common for both primary and additional arms. When a planet has a sufficiently large mass (≳3 thermal masses for (h/r) p = 0.1), only two spiral arms form interior to its orbit. The wave modes that would form a tertiary arm for smaller mass planets merge with the primary arm. Improvements in our understanding of the formation of spiral arms can provide crucial insights into the origin of observed spiral arms in protoplanetary disks.

  18. Flued head replacement alternatives

    International Nuclear Information System (INIS)

    Smetters, J.L.

    1987-01-01

    This paper discusses flued head replacement options. Section 2 discusses complete flued head replacement with a design that eliminates the inaccessible welds. Section 3 discusses alternate flued head support designs that can drastically reduce flued head installation costs. Section 4 describes partial flued head replacement designs. Finally, Section 5 discusses flued head analysis methods. (orig./GL)

  19. Stereotactic ablative body radiotherapy for non-small-cell lung cancer: setup reproducibility with novel arms-down immobilization.

    Science.gov (United States)

    Moore, Karen; Paterson, Claire; Hicks, Jonathan; Harrow, Stephen; McJury, Mark

    2016-12-01

    A clinical evaluation of the intrafraction and interfraction setup accuracy of a novel thermoplastic mould immobilization device and patient position in early-stage lung cancer being treated with stereotactic radiotherapy at the Beatson West of Scotland Cancer Centre, Glasgow, UK. 35 patients were immobilized in a novel, arms-down position, with a four-point Klarity ™ (Klarity Medical Products, Ohio, US) clear thermoplastic mould fixed to a SinMed (CIVCO Medical solutions, lowa, US) head and neck board. A knee support was also used for patient comfort and support. Pre- and post-treatment kilovoltage cone beam CT (CBCT) images were fused with the planning CT scan to determine intra- and interfraction motion. A total of 175 CBCT scans were analysed in the longitudinal, vertical and lateral directions. The mean intrafraction errors were 0.05 ± 0.77 mm (lateral), 0.44 ± 1.2 mm (superior-inferior) and -1.44 ± 1.35 mm (anteroposterior), respectively. Mean composite three-dimensional displacement vector was 2.14 ± 1.2 mm. Interfraction errors were -0.66 ± 2.35 mm (lateral), -0.13 ± 3.11 mm (superior-inferior) and 0.00 ± 2.94 mm (anteroposterior), with three-dimensional vector 4.08 ± 2.73 mm. Setup accuracy for lung image-guided stereotactic ablative radiotherapy using a unique immobilization device, where patients have arms by their sides, has been shown to be safe and favourably comparable to other published setup data where more complex and cumbersome devices were utilised. There was no arm toxicity reported and low arm doses. Advances in knowledge: We report on the accuracy of a novel patient immobilization device.

  20. Intraoperative imaging for patient safety and QA: detection of intracranial hemorrhage using C-arm cone-beam CT

    Science.gov (United States)

    Schafer, Sebastian; Wang, Adam; Otake, Yoshito; Stayman, J. W.; Zbijewski, Wojciech; Kleinszig, Gerhard; Xia, Xuewei; Gallia, Gary L.; Siewerdsen, Jeffrey H.

    2013-03-01

    Intraoperative imaging could improve patient safety and quality assurance (QA) via the detection of subtle complications that might otherwise only be found hours after surgery. Such capability could therefore reduce morbidity and the need for additional intervention. Among the severe adverse events that could be more quickly detected by high-quality intraoperative imaging is acute intracranial hemorrhage (ICH), conventionally assessed using post-operative CT. A mobile C-arm capable of high-quality cone-beam CT (CBCT) in combination with advanced image reconstruction techniques is reported as a means of detecting ICH in the operating room. The system employs an isocentric C-arm with a flat-panel detector in dual gain mode, correction of x-ray scatter and beam-hardening, and a penalized likelihood (PL) iterative reconstruction method. Performance in ICH detection was investigated using a quantitative phantom focusing on (non-contrast-enhanced) blood-brain contrast, an anthropomorphic head phantom, and a porcine model with injection of fresh blood bolus. The visibility of ICH was characterized in terms of contrast-to-noise ratio (CNR) and qualitative evaluation of images by a neurosurgeon. Across a range of size and contrast of the ICH as well as radiation dose from the CBCT scan, the CNR was found to increase from ~2.2-3.7 for conventional filtered backprojection (FBP) to ~3.9-5.4 for PL at equivalent spatial resolution. The porcine model demonstrated superior ICH detectability for PL. The results support the role of high-quality mobile C-arm CBCT employing advanced reconstruction algorithms for detecting subtle complications in the operating room at lower radiation dose and lower cost than intraoperative CT scanners and/or fixedroom C-arms. Such capability could present a potentially valuable aid to patient safety and QA.

  1. Evaluation of arm-leg coordination in flat breaststroke.

    Science.gov (United States)

    Chollet, D; Seifert, L; Leblanc, H; Boulesteix, L; Carter, M

    2004-10-01

    This study proposes a new method to evaluate arm-leg coordination in flat breaststroke. Five arm and leg stroke phases were defined with a velocity-video system. Five time gaps quantified the time between arm and leg actions during three paces of a race (200 m, 100 m and 50 m) in 16 top level swimmers. Based on these time gaps, effective glide, effective propulsion, effective leg insweep and effective recovery were used to identify the different stroke phases of the body. A faster pace corresponded to increased stroke rate, decreased stroke length, increased propulsive phases, shorter glide phases, and a shorter T1 time gap, which measured the effective body glide. The top level swimmers showed short time gaps (T2, T3, T4, measuring the timing of arm-leg recoveries), which reflected the continuity in arm and leg actions. The measurement of these time gaps thus provides a pertinent evaluation of swimmers' skill in adapting their arm-leg coordination to biomechanical constraints.

  2. Ray tracing reconstruction investigation for C-arm tomosynthesis

    Science.gov (United States)

    Malalla, Nuhad A. Y.; Chen, Ying

    2016-04-01

    C-arm tomosynthesis is a three dimensional imaging technique. Both x-ray source and the detector are mounted on a C-arm wheeled structure to provide wide variety of movement around the object. In this paper, C-arm tomosynthesis was introduced to provide three dimensional information over a limited view angle (less than 180o) to reduce radiation exposure and examination time. Reconstruction algorithms based on ray tracing method such as ray tracing back projection (BP), simultaneous algebraic reconstruction technique (SART) and maximum likelihood expectation maximization (MLEM) were developed for C-arm tomosynthesis. C-arm tomosynthesis projection images of simulated spherical object were simulated with a virtual geometric configuration with a total view angle of 40 degrees. This study demonstrated the sharpness of in-plane reconstructed structure and effectiveness of removing out-of-plane blur for each reconstruction algorithms. Results showed the ability of ray tracing based reconstruction algorithms to provide three dimensional information with limited angle C-arm tomosynthesis.

  3. Bottom head assembly

    International Nuclear Information System (INIS)

    Fife, A.B.

    1998-01-01

    A bottom head dome assembly is described which includes, in one embodiment, a bottom head dome and a liner configured to be positioned proximate the bottom head dome. The bottom head dome has a plurality of openings extending there through. The liner also has a plurality of openings extending there through, and each liner opening aligns with a respective bottom head dome opening. A seal is formed, such as by welding, between the liner and the bottom head dome to resist entry of water between the liner and the bottom head dome at the edge of the liner. In the one embodiment, a plurality of stub tubes are secured to the liner. Each stub tube has a bore extending there through, and each stub tube bore is coaxially aligned with a respective liner opening. A seat portion is formed by each liner opening for receiving a portion of the respective stub tube. The assembly also includes a plurality of support shims positioned between the bottom head dome and the liner for supporting the liner. In one embodiment, each support shim includes a support stub having a bore there through, and each support stub bore aligns with a respective bottom head dome opening. 2 figs

  4. Defining and comparing learning actions in two simulation modalities: students training on a latex arm and each other's arms.

    Science.gov (United States)

    Ravik, Monika; Havnes, Anton; Bjørk, Ida Torunn

    2017-12-01

    To explore, describe and compare learning actions that nursing students used during peripheral vein cannulation training on a latex arm or each other's arms in a clinical skills centre. Simulation-based training is thought to enhance learning and transfer of learning from simulation to the clinical setting and is commonly recommended in nursing education. What students actually are doing during simulation-based training is, however, less explored. The analysis of learning actions used during simulation-based training could contribute to development and improvement of simulation as a learning strategy in nursing education. A qualitative explorative and descriptive research design, involving content analysis of video recordings, was used. Video-supported observation of nine nursing students practicing vein cannulation was conducted in a clinical skills centre in late 2012. The students engaged in various learning actions. Students training on a latex arm used a considerably higher number of learning actions relative to those training on each other's arms. In both groups, students' learning actions consisted mainly of seeking and giving support. The teacher provided students training on each other's arms with detailed feedback regarding insertion of the cannula into the vein, while those training on a latex arm received sparse feedback from the teacher and fellow students. The teacher played an important role in facilitating nursing students' practical skill learning during simulation. The provision of support from both teachers and students should be emphasised to ensure that nursing students' learning needs are met. This study suggest that student nurses may be differently and inadequately prepared in peripheral vein cannulation in two simulation modalities used in the academic setting; training on a latex arm and on each other's arms. © 2017 John Wiley & Sons Ltd.

  5. A randomized phase III trial comparing concomitant chemoradiotherapy versus radiotherapy alone in advanced head and neck cancers - mature results: Yoodhvir Singh Nagar, Lucknow Cancer Institute, India

    International Nuclear Information System (INIS)

    Singh, S.; Kumar, S.; Datta, N.R.

    2003-01-01

    To evaluate contribution of concomitant chemoradiotherapy (CTRT) over and above radiotherapy alone (RT) in previously untreated stage III/IV, squamous cell carcinoma of the head and neck (SCCH and N). Patients with cancers of oral cavity (OC), oropharynx (OP), supraglottis (SG) and hypopharynx (HP) were randomized into RT arm or CTRT arm. Radiotherapy was identical in both arms (70Gy/35 fractions/7 weeks). In CTRT arm concomitant cisplatin (35mg/m 2 ) was given weekly for seven cycles. Surgery was reserved for salvage purposes when required. From May 1996 to December 1998, 155 patients (RT=78, CTRT=77) were enrolled and 139 patients (RT1,CTRT=68) were assessable. Over 90% patients in both arms completed planned treatment. The complete response rate was 51% in RT arm and 71% in CTRT arm (p=0.017). The median disease free survival (DFS) and overall survival (OS) in RT arm and CTRT arm were 3 months vs. 11 months (p=0.0009) and 9 months vs. 26 months (p=0.01) respectively. The 5-year DFS and OS in the two arms were 10% vs. 27% (p=0.000) and 16% vs. 29% (p=0.01) respectively. Acute grade III toxicity was comparable in both the arms (12% vs. 16%, p=0.74). Late grade I/II toxicity was higher in CTRT arm (70% vs. 51%, p=0.09). Serious late toxicities were not seen in both arms. On univariate analysis the favorable factors for immediate response were protocol (CTRT better), primary site (SG and OP better than OC and HP), T-stage (T1-T2 better), Nodes (N0 better than N+), Stage (III > IV), KPS (>80) and lesser overall treatment time (OTT). Multivariate analysis retained protocol, T stage, N stage and OTT as factors independently affecting the immediate response. Addition of concomitant weekly cisplatin (35mg/m 2 ) to radiotherapy improves the likelihood of local control, DFS and OS with acceptable acute and late toxicities and can be recommended as a standard form of treatment in advanced SCCH and N

  6. Kinematic decomposition and classification of octopus arm movements.

    Science.gov (United States)

    Zelman, Ido; Titon, Myriam; Yekutieli, Yoram; Hanassy, Shlomi; Hochner, Binyamin; Flash, Tamar

    2013-01-01

    The octopus arm is a muscular hydrostat and due to its deformable and highly flexible structure it is capable of a rich repertoire of motor behaviors. Its motor control system uses planning principles and control strategies unique to muscular hydrostats. We previously reconstructed a data set of octopus arm movements from records of natural movements using a sequence of 3D curves describing the virtual backbone of arm configurations. Here we describe a novel representation of octopus arm movements in which a movement is characterized by a pair of surfaces that represent the curvature and torsion values of points along the arm as a function of time. This representation allowed us to explore whether the movements are built up of elementary kinematic units by decomposing each surface into a weighted combination of 2D Gaussian functions. The resulting Gaussian functions can be considered as motion primitives at the kinematic level of octopus arm movements. These can be used to examine underlying principles of movement generation. Here we used combination of such kinematic primitives to decompose different octopus arm movements and characterize several movement prototypes according to their composition. The representation and methodology can be applied to the movement of any organ which can be modeled by means of a continuous 3D curve.

  7. Star distribution in the Orion spiral arm

    International Nuclear Information System (INIS)

    Basharina, T.S.; Pavlovskaya, E.D.; Filippova, A.A.

    1985-01-01

    The structure of the Orion spiral arm is studied by numerical experiments, assuming that in each direction considered the star distribution along the line of sight is a combination of two Gaussian laws. The corresponding parameters are evaluated for four Milky Way fields; the bimodal laws now fit the observations by the chi 2 criterion. In the Orion arm the line-of-sight star densities follow asymmetric curves, steeper at the outer edge of the arm

  8. Analysis of the motor behavior of a patient submitted to radical mastectomy - doi:10.5020/18061230.2009.p61

    Directory of Open Access Journals (Sweden)

    Lucas Flocke Hack

    2012-01-01

    Full Text Available Objective: To analyze the motor behavior of a patient in late postoperative of radical mastectomy during the accomplishment of some daily life activities, her gait and her body posture. Methods: This was an observational and descriptive case report study developed in an academic institution at Novo Hamburgo/RS, Brazil. By means of video recording, the accomplishment of daily life activities, the gait and body posture of a mastectomy patient were evaluated. Results: The most important alterations found were: increased base of support, torso swinging on gait, “S” shape scoliosis, accentuation of the spine physiologic curves and compensatory attitudes for reaching greater amplitudes of arm elevation at the same side of the surgery. Conclusion: We conclude that motor behavior alterations after surgery of radical mastectomy can be reasonably minimized, remaining a small reduction of movement amplitude and of muscular strength on upper limb and torso.

  9. ARM Unmanned Aerial Systems Implementation Plan

    Energy Technology Data Exchange (ETDEWEB)

    Schmid, Beat [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Ivey, Mark [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-11-01

    Recent advances in Unmanned Aerial Systems (UAS) coupled with changes in the regulatory environment for operations of UAS in the National Airspace increase the potential value of UAS to the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility. UAS include unmanned aerial vehicles (UAV) and tethered balloon systems (TBS). The roles UAVs and TBSs could play within the ARM Facility, particularly science questions they could help address, have been discussed in several workshops, reports, and vision documents, including: This document describes the implementation of a robust and vigorous program for use of UAV and TBS for the science missions ARM supports.

  10. Passive detection of nuclear-armed SLCMs

    International Nuclear Information System (INIS)

    Sagdeev, R.Z.; Prilutsky, O.F.; Frolov, V.A.

    1992-01-01

    Effective procedures have been developed, using national technical measures (photoreconnaissance satellites, radiointercept stations, etc.), for verification of reductions in land-based intercontinental ballistic missiles, such as marine-based ballistic missiles, and strategic bombers. However, there is agreement on procedures for verifying limitations of numbers of long-range nuclear-armed cruise missiles. The difficulties in developing such procedures are sometimes regarded (by opponents of nuclear disarmament) as a reason why cruise missiles based on ships and submarines ought not to be limited by future arms-reduction treaties. This paper considers the detectability of nuclear-armed cruise missiles through the penetrating radiation emitted spontaneously from their warheads

  11. Control of octopus arm extension by a peripheral motor program.

    Science.gov (United States)

    Sumbre, G; Gutfreund, Y; Fiorito, G; Flash, T; Hochner, B

    2001-09-07

    For goal-directed arm movements, the nervous system generates a sequence of motor commands that bring the arm toward the target. Control of the octopus arm is especially complex because the arm can be moved in any direction, with a virtually infinite number of degrees of freedom. Here we show that arm extensions can be evoked mechanically or electrically in arms whose connection with the brain has been severed. These extensions show kinematic features that are almost identical to normal behavior, suggesting that the basic motor program for voluntary movement is embedded within the neural circuitry of the arm itself. Such peripheral motor programs represent considerable simplification in the motor control of this highly redundant appendage.

  12. Technology and the arms race

    International Nuclear Information System (INIS)

    MacKenzie, D.

    1988-01-01

    This article makes a review of the book Innovation and the Arms Race: How the United States and the Soviet Union Develop New Military Technologies written by Matthew Evangelista. For at least the last two decades, scholars have struggled to come to grips with the role of technological change in the arms race. Possible relationships between theories on technology and politics are examined. The contrasts between U.S. and Soviet approaches are highlighted

  13. What are Head Cavities? - A History of Studies on Vertebrate Head Segmentation.

    Science.gov (United States)

    Kuratani, Shigeru; Adachi, Noritaka

    2016-06-01

    Motivated by the discovery of segmental epithelial coeloms, or "head cavities," in elasmobranch embryos toward the end of the 19th century, the debate over the presence of mesodermal segments in the vertebrate head became a central problem in comparative embryology. The classical segmental view assumed only one type of metamerism in the vertebrate head, in which each metamere was thought to contain one head somite and one pharyngeal arch, innervated by a set of cranial nerves serially homologous to dorsal and ventral roots of spinal nerves. The non-segmental view, on the other hand, rejected the somite-like properties of head cavities. A series of small mesodermal cysts in early Torpedo embryos, which were thought to represent true somite homologs, provided a third possible view on the nature of the vertebrate head. Recent molecular developmental data have shed new light on the vertebrate head problem, explaining that head mesoderm evolved, not by the modification of rostral somites of an amphioxus-like ancestor, but through the polarization of unspecified paraxial mesoderm into head mesoderm anteriorly and trunk somites posteriorly.

  14. Optimizing Armed Forces Capabilities for Hybrid Warfare – New Challenge for Slovak Armed Forces

    Directory of Open Access Journals (Sweden)

    Peter PINDJÁK

    2015-09-01

    Full Text Available The paper deals with the optimization of military capabilities of the Slovak Armed Forces for conducting operations in a hybrid conflict, which represents one of the possible scenarios of irregular warfare. Whereas in the regular warfare adversaries intend to eliminate the centers of gravity of each other, most often command and control structures, in irregular conflicts, the center of gravity shifts towards the will and cognitive perception of the target population. Hybrid warfare comprises a thoroughly planned combination of conventional military approaches and kinetic operations with subversive, irregular activities, including information and cyber operations. These efforts are often accompanied by intensified activities of intelligence services, special operation forces, and even mercenary and other paramilitary groups. The development of irregular warfare capabilities within the Slovak Armed Forces will require a progressive transformation process that may turn the armed forces into a modern and adaptable element of power, capable of deployment in national and international crisis management operations.

  15. Superconductor devices useful for disk drives and the like

    International Nuclear Information System (INIS)

    Barnes, F.S.

    1989-01-01

    This patent describes an apparatus for exchanging information with a circular media and which includes a drive mechanism for radially positioning a head relative to the media with the head including structure for imparting information to the media, for detecting information on the media, or both, comprising: an arm having at least one head attached thereto wherein the head is capable of interchanging information with the media; and bearing means for suspending the arm, the bearing means including a superconductor layer element, a magnetic field source element and means mounting one of the elements on the arm and the other the element in interfacing relationship to the one of the elements so that the interfacing relationship is maintained throughout the radial travel of the arm. A drive for exchanging information between a circular media mounted on a spindle and a head comprising an elongated arm having the head attached thereto and a layer of superconductor material on one side thereof, the arm being radially positionable over the surface of the circular media, an annular magnet means in peripheral relation to the circular media and oriented to direct a magnetic field towards the arm superconductor layer for maintaining a relatively constant spacing between the arm and the media throughout the radial travel of the arm relative to the circular media

  16. Radial head button holing: a cause of irreducible anterior radial head dislocation

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Su-Mi; Chai, Jee Won; You, Ja Yeon; Park, Jina [Seoul National University Seoul Metropolitan Government Boramae Medical Center, Department of Radiology, Seoul (Korea, Republic of); Bae, Kee Jeong [Seoul National University Seoul Metropolitan Government Boramae Medical Center, Department of Orthopedic Surgery, Seoul (Korea, Republic of)

    2016-10-15

    ''Buttonholing'' of the radial head through the anterior joint capsule is a known cause of irreducible anterior radial head dislocation associated with Monteggia injuries in pediatric patients. To the best of our knowledge, no report has described an injury consisting of buttonholing of the radial head through the annular ligament and a simultaneous radial head fracture in an adolescent. In the present case, the radiographic findings were a radial head fracture with anterior dislocation and lack of the anterior fat pad sign. Magnetic resonance imaging (MRI) clearly demonstrated anterior dislocation of the fractured radial head through the torn annular ligament. The anterior joint capsule and proximal portion of the annular ligament were interposed between the radial head and capitellum, preventing closed reduction of the radial head. Familiarity with this condition and imaging findings will aid clinicians to make a proper diagnosis and fast decision to perform an open reduction. (orig.)

  17. Simple model of the arms race

    International Nuclear Information System (INIS)

    Zane, L.I.

    1982-01-01

    A simple model of a two-party arms race is developed based on the principle that the race will continue so long as either side can unleash an effective first strike against the other side. The model is used to examine how secrecy, the ABM, MIRV-ing, and an MX system affect the arms race

  18. Kinematic decomposition and classification of octopus arm movements

    Directory of Open Access Journals (Sweden)

    Ido eZelman

    2013-05-01

    Full Text Available The octopus arm is a muscular hydrostat and due to its deformable and highly flexible structure it is capable of a rich repertoire of motor behaviors. Its motor control system uses planning principles and control strategies unique to muscular hydrostats. We previously reconstructed a data set of octopus arm movements from records of natural movements using a sequence of 3D curves describing the virtual backbone of arm configurations. Here we describe a novel representation of octopus arm movements in which a movement is characterized by a pair of surfaces that represent the curvature and torsion values of points along the arm as a function of time. This representation allowed us to explore whether the movements are built up of elementary kinematic units by decomposing each surface into a weighted combination of 2D Gaussian functions. The resulting Gaussian functions can be considered as motion primitives at the kinematic level of octopus arm movements. These can be used to examine underlying principles of movement generation. Here we used combination of such kinematic primitives to decompose different octopus arm movements and characterize several movement prototypes according to their composition. The representation and methodology can be applied to the movement of any organ which can be modeled by means of a continuous 3D curve.

  19. ATLAS software stack on ARM64

    CERN Document Server

    Smith, Joshua Wyatt; The ATLAS collaboration

    2016-01-01

    The ATLAS experiment explores new hardware and software platforms that, in the future, may be more suited to its data intensive workloads. One such alternative hardware platform is the ARM architecture, which is designed to be extremely power efficient and is found in most smartphones and tablets. CERN openlab recently installed a small cluster of ARM 64-bit evaluation prototype servers. Each server is based on a single-socket ARM 64-bit system on a chip, with 32 Cortex-A57 cores. In total, each server has 128 GB RAM connected with four fast memory channels. This paper reports on the port of the ATLAS software stack onto these new prototype ARM64 servers. This included building the "external" packages that the ATLAS software relies on. Patches were needed to introduce this new architecture into the build as well as patches that correct for platform specific code that caused failures on non-x86 architectures. These patches were applied such that porting to further platforms will need no or only very little adj...

  20. Does "hidden undercuffing" occur among obese patients? Effect of arm sizes and other predictors of the difference between wrist and upper arm blood pressures.

    Science.gov (United States)

    Doshi, Hardik; Weder, Alan B; Bard, Robert L; Brook, Robert D

    2010-02-01

    Arm size can affect the accuracy of blood pressure (BP) measurement, and "undercuffing" of large upper arms is likely to be a growing problem. Therefore, the authors investigated the relationship between upper arm and wrist readings. Upper arm and wrist circumferences and BP were measured in 261 consecutive patients. Upper arm auscultation and wrist BP was measured in triplicate, rotating measurements every 30 seconds between sites. Upper arm BP was 131.9+/-20.6/71.6+/-12.6 mm Hg in an obese population (body mass index, 30.6+/-6.6 kg/m(2)) with mean upper arm size of 30.7+/-5.1 cm. Wrist BP was higher (2.6+/-9.2 mm Hg and 4.9+/-6.6 mm Hg, respectively, PBlood Pressure (JNC 7) strata (kappa value=0.27-0.71), and the difference was >or=5 mm Hg in 72% of the patients. The authors conclude that there was poor concordance between arm and wrist BP measurement and found no evidence that "hidden undercuffing" was associated with obesity; therefore, they do not support routine use of wrist BP measurements.

  1. Postradiotherapy quality of life for head-and-neck cancer patients is independent of xerostomia

    International Nuclear Information System (INIS)

    Ringash, Jolie; Warde, Padraig; Lockwood, Gina; O'Sullivan, Brian; Waldron, John; Cummings, Bernard

    2005-01-01

    Purpose: To determine the relationship between quality of life (QOL) and xerostomia over time for patients undergoing radiotherapy (RT) for head-and-neck cancer in a prospective clinical trial. Methods and materials: Patients with head-and-neck cancer were randomized to pilocarpine (n = 65) vs. placebo (n = 65) during RT. QOL was measured using the McMaster Head and Neck Radiotherapy Questionnaire (HNRQ). Xerostomia was measured on a linear analog scale. No statistically significant differences were observed between arms; all 130 patients were analyzed together. Results: Baseline QOL data were obtained for 98.5% of participants. The baseline HNRQ score of 5.7 declined significantly to 4.0 (p <0.0001) by RT Week 6 and returned to baseline (5.8) by 6 months after treatment. This represents a large, clinically important change of 1.7 of 7 (24%; effect size 1.34). The decline in HNRQ score during RT paralleled the onset of xerostomia on the linear analog scale (r = 0.36 at 1 month). After treatment, the QOL scores recovered without improvement in xerostomia. The trajectory of the linear analog scale score resembled that of the HNRQ's single xerostomia question (r = 0.75 at 1 month). Conclusion: Quality of life recovers to baseline after RT, despite persistent xerostomia. Either a response shift occurs or xerostomia in the absence of acute mucositis has a relatively small influence on overall QOL

  2. Arms control, nonproliferation, and US national security

    International Nuclear Information System (INIS)

    Pilat, J.F.

    1985-01-01

    The continuation of the arms race and the failure of arms control and disarmament negotiations lend support to the belief that US and Soviet power, prestige, and security depend upon nuclear weapons. Therefore, the argument goes, the non-nuclear-weapon states (particularly those that are not allied with nuclear-weapon states and do not share their nuclear shield) may conclude that they would be well served by possession of these weapons. In this sense, the failure of nuclear arms reductions could create incentives for further proliferation

  3. To Arm or Not to Arm: The Case Against Arming Vietnam and the Philippines

    Science.gov (United States)

    2015-04-13

    designed to allay 9 Leaf (accessed Oct 24, 2014). 10 Ankit Panda , “What to Expect if the U.S. Lifts...their animated populations. Despite the rhetoric, no ideology or nation is monolithic, thus opportunities exist to improve the U.S.-Sino...Joint Forces Quarterly 2 (2014): 76-80. Panda , Ankit. “What to Expect if the U.S. Lifts Its Vietnam Arms Embargo.” The Diplomat. September 29

  4. Stellar complexes in spiral arms of galaxies

    Science.gov (United States)

    Efremov, Yu. N.

    The history of the introduction and development of the star complexes conception is briefly described. These large groups of stars were picked out and named as such ones in our Galaxy with argumentation and evidence for their physical unity (using the Cepheid variables the distances and ages of which are easy determined from their periods); anyway earlier the complexes were noted along the spiral arms of the Andromeda galaxy, but were not recognized as a new kind of star group. The chains of complexes along the spiral arms are observed quite rarely; their origin is explained by magneto- gravitational or purely gravitational instability developing along the arm. It is not clear why these chains are quite a rare phenomenon - and more so why sometimes the regular chain of complexes are observed in one arm only. Probably intergalactic magnetic field participated in formation of such chains. Apart from the complexes located along the arms, there are isolated giant complexes known (up to 700 pc in diameter) which look like super-gigantic but rather rarefied globular clusters. Until now only two of these formations are studied, in NGC 6946 and M51.

  5. Changing patterns of arms transfers

    International Nuclear Information System (INIS)

    Wulf, H.

    1998-01-01

    Three factors in the international system have been of importance for the trade of arms: the role of the main actors on the supply side and since 1970 on the demand side, the permanently increasing importance of economics, and the balance trade, industrial capacity and jobs in supplier countries and purchasing power of potential importers. Two political events in 1991 had lasting effect on the development of the trade in arms: the dissolution of Soviet Union and the Gulf War

  6. Driving pockels cells in multi-arm lasers

    International Nuclear Information System (INIS)

    Carder, B.M.

    1978-01-01

    This paper describes the method used to drive Pockels cells on the 20-arm Shiva laser for inertial confinement fusion research at the Lawrence Livermore Laboratory. Shiva became operational last fall, and has just completed a series of 20-arm target shots. It uses two pockels cell gates in each laser arm for suppression of amplified spontaneous emission (ASE) that can damage or destroy the target before the main pulse arrives. Two additional Pockels cells are used in the preamplification stages, so that a total of 42 cells must be driven by the pulser system

  7. Heading-vector navigation based on head-direction cells and path integration.

    Science.gov (United States)

    Kubie, John L; Fenton, André A

    2009-05-01

    Insect navigation is guided by heading vectors that are computed by path integration. Mammalian navigation models, on the other hand, are typically based on map-like place representations provided by hippocampal place cells. Such models compute optimal routes as a continuous series of locations that connect the current location to a goal. We propose a "heading-vector" model in which head-direction cells or their derivatives serve both as key elements in constructing the optimal route and as the straight-line guidance during route execution. The model is based on a memory structure termed the "shortcut matrix," which is constructed during the initial exploration of an environment when a set of shortcut vectors between sequential pairs of visited waypoint locations is stored. A mechanism is proposed for calculating and storing these vectors that relies on a hypothesized cell type termed an "accumulating head-direction cell." Following exploration, shortcut vectors connecting all pairs of waypoint locations are computed by vector arithmetic and stored in the shortcut matrix. On re-entry, when local view or place representations query the shortcut matrix with a current waypoint and goal, a shortcut trajectory is retrieved. Since the trajectory direction is in head-direction compass coordinates, navigation is accomplished by tracking the firing of head-direction cells that are tuned to the heading angle. Section 1 of the manuscript describes the properties of accumulating head-direction cells. It then shows how accumulating head-direction cells can store local vectors and perform vector arithmetic to perform path-integration-based homing. Section 2 describes the construction and use of the shortcut matrix for computing direct paths between any pair of locations that have been registered in the shortcut matrix. In the discussion, we analyze the advantages of heading-based navigation over map-based navigation. Finally, we survey behavioral evidence that nonhippocampal

  8. F-18 FDG PET with coincidence detection, dual-head gamma camera, initial experience in oncology

    Energy Technology Data Exchange (ETDEWEB)

    Chu, J.M.G.; Pocock, N.; Quach, T.; Camden, B.M.C. [Liverpool Health Services, Liverpool, NSW (Australia). Department of Nuclear Medicine and Clinical Ultrasound

    1998-06-01

    Full text: The development of Co-incidence Detection (CD) in gamma camera technology has allowed the use of positron radiopharmaceuticals in clinical practice without dedicated PET facilities. We report our initial experience of this technology in Oncological applications. All patients were administered 200 MBq of F- 18 FDG intravenously in a fasting state, with serum glucose below 8.9 mmol/L., and hydration well maintained. Tomography was performed using an ADAC Solus Molecular Co-incidence Detection (MCD) dual-head gamma camera, 60 minutes after administration and immediately after voiding. Tomography of the torso required up to three collections depending on the length of the patient, with each collection requiring 32 steps of 40 second duration, and a 50% overlap. Tomography of the brain required a single collection with 32 steps of 80 seconds. Patients were scanned in the supine position. An iterative reconstruction algorithm was employed without attenuation correction. All patients had histologically confirmed malignancy. Scan findings were correlated with results of all conventional diagnostic imaging procedures that were pertinent to the evaluation and management of each individual patient`s disease. Correlation with tumour type and treatment status was also undertaken. F-18 FDG uptake as demonstrated by CD-PET was increased in tumour bearing sites. The degree of increased uptake varied with tumour type and with treatment status. Our initial experience with CD-PET has been very encouraging, and has led us to undertake prospective short and long term studies to define its role in oncology

  9. Energy Optimal Trajectories in Human Arm Motion Aiming for Assistive Robots

    Directory of Open Access Journals (Sweden)

    Lelai Zhou

    2017-01-01

    Full Text Available The energy expenditure in human arm has been of great interests for seeking optimal human arm trajectories. This paper presents a new way for calculating metabolic energy consumption of human arm motions. The purpose is to reveal the relationship between the energy consumption and the trajectory of arm motion, and further, the acceleration and arm orientation contributions. Human arm motion in horizontal plane is investigated by virtue of Qualisys motion capture system. The motion data is post-processed by a biomechanical model to obtain the metabolic expenditure. Results on the arm motion kinematics, dynamics and metabolic energy consumption, are included.

  10. Effect of standard cuff on blood pressure readings in patients with obese arms. How frequent are arms of a 'large circumference'?

    Science.gov (United States)

    Fonseca-Reyes, Salvador; de Alba-García, Javier García; Parra-Carrillo, José Z; Paczka-Zapata, José Antonio

    2003-06-01

    To measure the effect on blood pressure readings when a standard cuff is used on patients with arms of a large circumference, and to determine the frequency of arms of a large circumference. Blood pressures were taken in 120 subjects with an arm circumference greater than 33 cm. Also, the arm circumference was determined in 244 patients from a family health unit, and in 216 patients from a hypertension clinic. A mercury sphygmomanometer and two different cuff sizes were used in a random sequence; therefore, 60 patients' blood pressure were first measured with a large cuff, followed by a standard cuff; the opposite sequence was then applied for another 60 patients. With the obtained values and using a regression analysis, the difference in blood pressure overestimation was calculated. Arm circumference measurement percentages were used to determine the frequency of arms of a large circumference. Both systolic and diastolic blood pressures were significantly greater when the standard cuff was used. For every 5 cm increase in arm circumference, starting at 35 cm, a 2-5 mmHg increase in systolic blood pressure, and a 1-3 mmHg increase in diastolic blood pressure was observed. The prevalence of arms with a large circumference in the family medicine unit and hypertension clinic was 42% and 41.8%, respectively. There is an overestimation of blood pressure when a standard cuff is used in obese subjects. The high prevalence of these individuals in our environment, both in the hypertensive and normotensive population, makes it necessary to have on hand different sizes of cuffs for taking blood pressure in order to avoid incorrect decisions.

  11. Head injury: audit of a clinical guideline to justify head CT

    International Nuclear Information System (INIS)

    Haydon, Nicholas B.

    2013-01-01

    Head injury causes significant morbidity and mortality, and there is contention about which patients to scan. The UK National Health Service Clinical Guideline (CG) 56 provides criteria for selecting patients with clinically important brain injury who may benefit from a head CT scan, while minimising the radiation and economic burden of scanning patients without significant injury. This study aims to audit the documentation of the use of these guidelines in a busy UK trauma hospital and discusses the comparison with an Australian (New South Wales (NSW) ) head injury guideline. A retrospective cohort study of 480 patients presenting with head injury to the emergency department over 2 months was performed. The patient notes were assessed for documentation of each aspect of the clinical guidelines. Criteria were established to assess the utilisation of the CG 56. A database of clinical data was amalgamated with the head CT scan results for each patient. For the UK CG 56, 73% of the criteria were documented, with the least documented being 'signs of basal skull fracture' and 'amnesia of events'. Thirty-two per cent of patients received head CT and of these, 24% (37 patients) were reported to have pathology. Twenty-four patients underwent head CT without clinical justification being documented, none of which had reported pathology on CT. The study shows that the head injury guidelines are not being fully utilised at a major UK trauma hospital, resulting in 5% of patients being exposed to ionising radiation without apparent documented clinical justification. The NSW guideline has distinct differences to the CG 56, with a more complex algorithm and an absence of specific time frames for head CT completion. The results suggest a need for further education and awareness of head injury clinical guidelines.

  12. Robots testing robots: ALAN-Arm, a humanoid arm for the testing of robotic rehabilitation systems.

    Science.gov (United States)

    Brookes, Jack; Kuznecovs, Maksims; Kanakis, Menelaos; Grigals, Arturs; Narvidas, Mazvydas; Gallagher, Justin; Levesley, Martin

    2017-07-01

    Robotics is increasing in popularity as a method of providing rich, personalized and cost-effective physiotherapy to individuals with some degree of upper limb paralysis, such as those who have suffered a stroke. These robotic rehabilitation systems are often high powered, and exoskeletal systems can attach to the person in a restrictive manner. Therefore, ensuring the mechanical safety of these devices before they come in contact with individuals is a priority. Additionally, rehabilitation systems may use novel sensor systems to measure current arm position. Used to capture and assess patient movements, these first need to be verified for accuracy by an external system. We present the ALAN-Arm, a humanoid robotic arm designed to be used for both accuracy benchmarking and safety testing of robotic rehabilitation systems. The system can be attached to a rehabilitation device and then replay generated or human movement trajectories, as well as autonomously play rehabilitation games or activities. Tests of the ALAN-Arm indicated it could recreate the path of a generated slow movement path with a maximum error of 14.2mm (mean = 5.8mm) and perform cyclic movements up to 0.6Hz with low gain (<1.5dB). Replaying human data trajectories showed the ability to largely preserve human movement characteristics with slightly higher path length and lower normalised jerk.

  13. Molecular clouds in the Carina arm - the largest objects, associated regions of star formation, and the Carina arm in the Galaxy

    International Nuclear Information System (INIS)

    Grabelsky, D.A.; Cohen, R.S.; Bronfman, L.; Thaddeus, P.

    1988-01-01

    The Columbia CO survey of the southern Galactic plane is used to identify giant molecular clouds and cloud complexes in the Vela-Carina-Centaurus section of the Galaxy. Twenty-seven giant molecular clouds between l = 270 and 300 deg are catalogued and their heliocentric distances given. In addition, 16 clouds at l greater than 300 deg beyond the solar circle extend the catalog to include the very distant portion of the Carina arm. The most massive clouds in the catalog trace the Carina arm over 23 kpc in the plane of the Galaxy. The average mass of these objects is 1.4 x 10 to the 6th solar, and their average spacing along the arm is 700 pc. The composite distribution projected onto the Galactic plane of the largest molecular clouds in the Carina arm and of similarly massive clouds in the first and second quadrants strongly suggests that the Carina and Sagittarius arms form a single spiral arm about 40 kpc in length wrapping two-thirds of the way around the Galaxy. Descriptions of each cloud, including identification of associated star-forming regions, are presented in an appendix. 76 references

  14. Head Trauma: First Aid

    Science.gov (United States)

    First aid Head trauma: First aid Head trauma: First aid By Mayo Clinic Staff Most head trauma involves injuries that are minor and don't require ... 21, 2015 Original article: http://www.mayoclinic.org/first-aid/first-aid-head-trauma/basics/ART-20056626 . Mayo ...

  15. A Unified Approach for Reporting ARM Measurement Uncertainties Technical Report

    Energy Technology Data Exchange (ETDEWEB)

    Campos, E [Argonne National Lab. (ANL), Argonne, IL (United States); Sisterson, Douglas [Argonne National Lab. (ANL), Argonne, IL (United States)

    2016-12-01

    The U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility is observationally based, and quantifying the uncertainty of its measurements is critically important. With over 300 widely differing instruments providing over 2,500 datastreams, concise expression of measurement uncertainty is quite challenging. The ARM Facility currently provides data and supporting metadata (information about the data or data quality) to its users through a number of sources. Because the continued success of the ARM Facility depends on the known quality of its measurements, the Facility relies on instrument mentors and the ARM Data Quality Office (DQO) to ensure, assess, and report measurement quality. Therefore, an easily accessible, well-articulated estimate of ARM measurement uncertainty is needed. Note that some of the instrument observations require mathematical algorithms (retrievals) to convert a measured engineering variable into a useful geophysical measurement. While those types of retrieval measurements are identified, this study does not address particular methods for retrieval uncertainty. As well, the ARM Facility also provides engineered data products, or value-added products (VAPs), based on multiple instrument measurements. This study does not include uncertainty estimates for those data products. We propose here that a total measurement uncertainty should be calculated as a function of the instrument uncertainty (calibration factors), the field uncertainty (environmental factors), and the retrieval uncertainty (algorithm factors). The study will not expand on methods for computing these uncertainties. Instead, it will focus on the practical identification, characterization, and inventory of the measurement uncertainties already available in the ARM community through the ARM instrument mentors and their ARM instrument handbooks. As a result, this study will address the first steps towards reporting ARM measurement uncertainty

  16. Head and neck cancer

    International Nuclear Information System (INIS)

    Vogl, S.E.

    1988-01-01

    This book contains 10 chapters. Some of the titles are: Combined Surgical Resection and Irradiation for Head and Neck Cancers; Analysis of Radiation Therapy Oncology Group Head and Neck Database: Identification of Prognostic Factors and the Re-evaluation of American Joint Committee Stages; Combined Modality Approach to Head and Neck Cancer; Induction Combination Chemotherapy of Regionally Advanced Head and Neck Cancer; and Outcome after Complete Remission to Induction Chemotherapy in Head and Neck Cancer

  17. Effect of head restraint backset on head-neck kinematics in whiplash.

    Science.gov (United States)

    Stemper, Brian D; Yoganandan, Narayan; Pintar, Frank A

    2006-03-01

    Although head restraints were introduced in the 1960s as a countermeasure for whiplash, their limited effectiveness has been attributed to incorrect positioning. The effect of backset on cervical segmental angulations, which were previously correlated with spinal injury, has not been delineated. Therefore, the practical restraint position to minimize injury remains unclear. A parametric study of increasing head restraint backset between 0 and 140mm was conducted using a comprehensively validated computational model. Head retraction values increased with increasing backset, reaching a maximum value of 53.5mm for backsets greater than 60mm. Segmental angulation magnitudes, greatest at levels C5-C6 and C6-C7, reached maximum values during the retraction phase and increased with increasing backset. Results were compared to a previously published head restraint rating system, wherein lower cervical extension magnitudes from this study exceeded mean physiologic limits for restraint positions rated good, acceptable, marginal, and poor. As head restraint contact was the limiting factor in head retraction and segmental angulations, the present study indicates that minimizing whiplash injury may be accomplished by limiting head restraint backset to less than 60mm either passively or actively after impact.

  18. Putting the Glare of Publicity on International Arms Sales.

    Science.gov (United States)

    Hartman, William

    1992-01-01

    Reports on a United Nations committee recommendation that the Security Council establish a universal register of arms. Suggests that such a register would limit the destabilizing influence of major arms sales on developing nations. Argues that visibility of arms sales may help reduce their number. (DK)

  19. The Role of Ethics in International Arms Transfers

    Science.gov (United States)

    2016-06-01

    i THE ROLE OF ETHICS IN INTERNATIONAL ARMS TRANSFERS BY MAJOR ROB ARNETT A THESIS PRESENTED TO THE FACULTY OF THE SCHOOL OF...War’s Ends” provided the intellectual spark to explore the topic of ethics in international arms sales. Additionally, Dr. Murphy was kind enough to... ethics in American arms transfer policy to determine whether the Just War tradition’s jus ad bellum framework can help policymakers through a complex

  20. Arm to leg coordination in elite butterfly swimmers.

    Science.gov (United States)

    Chollet, D; Seifert, L; Boulesteix, L; Carter, M

    2006-04-01

    This study proposed the use of four time gaps to assess arm-to-leg coordination in the butterfly stroke at increasing race paces. Fourteen elite male swimmers swam at four velocities corresponding to the appropriate paces for, respectively, the 400-m, 200-m, 100-m, and 50-m events. The different stroke phases of the arm and leg were identified by video analysis and then used to calculate four time gaps (T1: time gap between entry of the hands in the water and the high break-even point of the first undulation; T2: time gap between the beginning of the hands' backward movement and the low break-even point of the first undulation; T3: time gap between the hands' arrival in a vertical plane to the shoulders and the high break-even point of the second undulation; T4: time gap between the hands' release from the water and the low break-even point of the second undulation), the values of which described the changing relationship of arm to leg movements over an entire stroke cycle. With increases in pace, elite swimmers increased the stroke rate, the relative duration of the arm pull, the recovery and the first downward movement of the legs, and decreased the stroke length, the relative duration of the arm catch phase and the body glide with arms forward (measured by T2), until continuity in the propulsive actions was achieved. Whatever the paces, the T1, T3, and T4 values were close to zero and revealed a high degree of synchronisation at key motor points of the arm and leg actions. This new method to assess butterfly coordination could facilitate learning and coaching by situating the place of the leg undulation in relation with the arm stroke.

  1. MPL-net at ARM Sites

    Science.gov (United States)

    Spinhirne, J. D.; Welton, E. J.; Campbell, J. R.; Berkoff, T. A.; Starr, David OC. (Technical Monitor)

    2002-01-01

    The NASA MPL-net project goal is consistent data products of the vertical distribution of clouds and aerosol from globally distributed lidar observation sites. The four ARM micro pulse lidars are a basis of the network to consist of over twelve sites. The science objective is ground truth for global satellite retrievals and accurate vertical distribution information in combination with surface radiation measurements for aerosol and cloud models. The project involves improvement in instruments and data processing and cooperation with ARM and other partners.

  2. Neurosurgical robotic arm drilling navigation system.

    Science.gov (United States)

    Lin, Chung-Chih; Lin, Hsin-Cheng; Lee, Wen-Yo; Lee, Shih-Tseng; Wu, Chieh-Tsai

    2017-09-01

    The aim of this work was to develop a neurosurgical robotic arm drilling navigation system that provides assistance throughout the complete bone drilling process. The system comprised neurosurgical robotic arm navigation combining robotic and surgical navigation, 3D medical imaging based surgical planning that could identify lesion location and plan the surgical path on 3D images, and automatic bone drilling control that would stop drilling when the bone was to be drilled-through. Three kinds of experiment were designed. The average positioning error deduced from 3D images of the robotic arm was 0.502 ± 0.069 mm. The correlation between automatically and manually planned paths was 0.975. The average distance error between automatically planned paths and risky zones was 0.279 ± 0.401 mm. The drilling auto-stopping algorithm had 0.00% unstopped cases (26.32% in control group 1) and 70.53% non-drilled-through cases (8.42% and 4.21% in control groups 1 and 2). The system may be useful for neurosurgical robotic arm drilling navigation. Copyright © 2016 John Wiley & Sons, Ltd.

  3. Safeguarding arms control

    International Nuclear Information System (INIS)

    Flanagan, S.J.

    1988-01-01

    This essay reviews the evolution of various safeguards concepts associated with U.S. Soviet arms control negotiations over the past twenty-five years. It explore in some detail the origins, nature, and effectiveness of the safeguards packages associated with six agreements: the Limited Test Ban Treaty (1963), the SALT I Interim Agreement (1972), the Anti-Ballistic Missile (ABM) Treaty (1972), the Threshold Test Ban Treaty (1974), the Peaceful Nuclear Explosions Treaty (1976) and the SALT II Treaty (1979). Finally, the implications of this historical record for developing future nuclear and conventional arms control accords and for shoring up existing pacts, such as the ABM Treaty, are assessed with a view towards practicable prescriptions for Western policymakers. The treaty eliminating intermediate-range nuclear forces (INF) incorporates several verification safeguards, and it is very likely that analogous measures would be attached to any accord constraining conventional forces in Europe

  4. The effect of household heads training about the use of treated bed nets on the burden of malaria and anaemia in under-five children: a cluster randomized trial in Ethiopia

    Directory of Open Access Journals (Sweden)

    Deribew Amare

    2012-01-01

    Full Text Available Abstract Background Long-lasting insecticide-treated bed nets (LLITN have demonstrated a significant effect in reducing malaria-related morbidity and mortality. However, barriers on the utilization of LLITN have hampered the desired outcomes. The aim of this study was to assess the effect of community empowerment on the burden of malaria and anaemia in under-five children in Ethiopia. Methods A cluster randomized trial was done in 22 (11 intervention and 11 control villages in south-west Ethiopia. The intervention consisted of tailored training of household heads about the proper use of LLITN and community network system. The burden of malaria and anaemia in under-five children was determined through mass blood investigation at baseline, six and 12 months of the project period. Cases of malaria and anaemia were treated based on the national protocol. The burden of malaria and anaemia between the intervention and control villages was compared using the complex logistic regression model by taking into account the clustering effect. Eight Focus group discussions were conducted to complement the quantitative findings. Results A total of 2,105 household heads received the intervention and the prevalence of malaria and anaemia was assessed among 2410, 2037 and 2612 under-five children at baseline, six and 12 months of the project period respectively. During the high transmission/epidemic season, children in the intervention arm were less likely to have malaria as compared to children in the control arm (OR = 0.42; 95%CI: 0.32, 0.57. Symptomatic malaria also steadily declined in the intervention villages compared to the control villages in the follow up periods. Children in the intervention arm were less likely to be anaemic compared to those in the control arm both at the high (OR = 0.84; 95%CI: 0.71, 0.99 and low (OR = 0.73; 95%CI: 0.60, 0.89 transmission seasons. Conclusion Training of household heads on the utilization of LLITN significantly

  5. Manipulator arm for a nuclear reactor vessel inspection device

    International Nuclear Information System (INIS)

    1980-01-01

    A manipulator arm for a reactor vessel in-service inspection apparatus is adapted to transport a transducer array for ultrasonic examination of welds at any point in the vessel. The removal of the inspection device from the reactor vessel in an emergency presents a problem where a relatively long manipulator arm is used. This invention provides an improved arm with means for changing the normal orientation of the arm to a shorter one to permit safe removal of the inspection device from the reactor vessel. (author)

  6. A software radio platform based on ARM and FPGA

    Directory of Open Access Journals (Sweden)

    Yang Xin.

    2016-01-01

    Full Text Available The rapid rise in computational performance offered by computer systems has greatly increased the number of practical software radio applications. A scheme presented in this paper is a software radio platform based on ARM and FPGA. FPGA works as the coprocessor together with the ARM, which serves as the core processor. ARM is used for digital signal processing and real-time data transmission, and FPGA is used for synchronous timing control and serial-parallel conversion. A SPI driver for real-time data transmission between ARM and FPGA under ARM-Linux system is provided. By adopting modular design, the software radio platform is capable of implementing wireless communication functions and satisfies the requirements of real-time signal processing platform for high security and broad applicability.

  7. Natural Resource Extraction, Armed Violence, and Environmental Degradation.

    Science.gov (United States)

    Downey, Liam; Bonds, Eric; Clark, Katherine

    2010-12-01

    The goal of this article is to demonstrate that environmental sociologists cannot fully explain the relationship between humans and the natural world without theorizing a link between natural resource extraction, armed violence, and environmental degradation. The authors begin by arguing that armed violence is one of several overlapping mechanisms that provide powerful actors with the means to (a) prevail over others in conflicts over natural resources and (b) ensure that natural resources critical to industrial production and state power continue to be extracted and sold in sufficient quantities to promote capital accumulation, state power, and ecological unequal exchange. The authors then identify 10 minerals that are critical to the functioning of the U.S. economy and/or military and demonstrate that the extraction of these minerals often involves the use of armed violence. They further demonstrate that armed violence is associated with the activities of the world's three largest mining companies, with African mines that receive World Bank funding, and with petroleum and rainforest timber extraction. The authors conclude that the natural resource base on which industrial societies stand is constructed in large part through the use and threatened use of armed violence. As a result, armed violence plays a critical role in fostering environmental degradation and ecological unequal exchange.

  8. US-Russian relations: the arms control agenda

    International Nuclear Information System (INIS)

    Potter, W.

    2001-01-01

    At a time when US-Russian relations are widely regarded to be in a state of flux, it is appropriate to examine the degree of continuity and change in the sphere of nuclear arms control. More specifically, this brief essay identifies a number of propositions about nuclear weapons, arms control, and nonproliferation that increasingly reflect the conventional wisdom in Washington, although these propositions may be neither true nor wise; and assesses the prospects for arms control progress in the areas of strategic and non-strategic nuclear weapons and nonproliferation in light of these prevailing views. (author)

  9. US-Russian relations: the arms control agenda

    Energy Technology Data Exchange (ETDEWEB)

    Potter, W

    2001-07-01

    At a time when US-Russian relations are widely regarded to be in a state of flux, it is appropriate to examine the degree of continuity and change in the sphere of nuclear arms control. More specifically, this brief essay identifies a number of propositions about nuclear weapons, arms control, and nonproliferation that increasingly reflect the conventional wisdom in Washington, although these propositions may be neither true nor wise; and assesses the prospects for arms control progress in the areas of strategic and non-strategic nuclear weapons and nonproliferation in light of these prevailing views. (author)

  10. The inter-arm diastolic blood pressure difference induced by one arm ischemia: a new approach to assess vascular endothelia function.

    Directory of Open Access Journals (Sweden)

    Weitong Hu

    Full Text Available OBJECTIVES: To evaluate whether inter-arm diastolic blood pressure difference (DBPl-r induced by one arm ischemia correlates with flow-mediated dilatation (FMD. METHODS: Bilateral arm BPs were simultaneously measured with two automatic devices and right brachial artery diameter (D was measured by ultrasound technique in 108 subjects (56 hypertensives and 52 normotensives. Following baseline diameter (D0 and BP measurement, right brachial artery was occluded for 5 minutes. The diameter was measured at 1, 1.5 and 2 min, and bilateral BPs measured at 3, 4 and 5 min after occlusion release. Their averages were recorded as post-D and post-BP, respectively. The difference between post-D and D0 (ΔD was calculated as the percentage increase of artery diameter (ΔD/D0. The BP difference between left and right arms was calculated as BPl-r, and the difference of post- BPl-r and baseline BPl-r was recorded as the net change of BPl-r (ΔBPl-r. RESULTS: At baseline, bilateral SBPs and DBPs were similar. Right arm ischemia induced significant DBP decline only in the right arm (68.8±12.7 vs 72.6±12.0 mmHg, P<0.05, which led to an increase of ΔDBPl-r (4.00±3.75 vs 0.78±4.47 mmHg, P<0.05. A positive correlation was seen between ΔD/D0 and ΔDBPl-r (r = 0.744, p<0.001. Furthermore, the correlation between age and ΔDBPl-r (r = -0.358, P<0.01 was similar to that between age and D/D0 (r = -0.398, P<0.01. Meanwhile, both ΔDBPl-r and ΔD/D0 were significantly lower in hypertensive patients than in normotensive patients. CONCLUSION: The inter-arm DBP difference induced by one arm ischemia may be a potential index for clinical evaluation of vascular endothelial function.

  11. Technology-supported training of arm-hand skills in stroke

    NARCIS (Netherlands)

    Timmermans, A.A.A.

    2010-01-01

    Impaired arm-hand performance is a serious consequence of stroke that is associated with reduced self-efficacy and poor quality of life. Task-oriented arm training is a therapy approach that is known to improve skilled arm-hand performance, even in chronic stages after stroke. At the start of this

  12. Kinematic feedback control laws for generating natural arm movements

    International Nuclear Information System (INIS)

    Kim, Donghyun; Jang, Cheongjae; Park, Frank C

    2014-01-01

    We propose a stochastic optimal feedback control law for generating natural robot arm motions. Our approach, inspired by the minimum variance principle of Harris and Wolpert (1998 Nature 394 780–4) and the optimal feedback control principles put forth by Todorov and Jordan (2002 Nature Neurosci. 5 1226–35) for explaining human movements, differs in two crucial respects: (i) the endpoint variance is minimized in joint space rather than Cartesian hand space, and (ii) we ignore the dynamics and instead consider only the second-order differential kinematics. The feedback control law generating the motions can be straightforwardly obtained by backward integration of a set of ordinary differential equations; these equations are obtained exactly, without any linear–quadratic approximations. The only parameters to be determined a priori are the variance scale factors, and for both the two-DOF planar arm and the seven-DOF spatial arm, a table of values is constructed based on the given initial and final arm configurations; these values are determined via an optimal fitting procedure, and consistent with existing findings about neuromuscular motor noise levels of human arm muscles. Experiments conducted with a two-link planar arm and a seven-DOF spatial arm verify that the trajectories generated by our feedback control law closely resemble human arm motions, in the sense of producing nearly straight-line hand trajectories, having bell-shaped velocity profiles, and satisfying Fitts Law. (paper)

  13. Brain-Machine Interface Enables Bimanual Arm Movements in Monkeys

    Science.gov (United States)

    Ifft, Peter J.; Shokur, Solaiman; Li, Zheng; Lebedev, Mikhail A.; Nicolelis, Miguel A. L.

    2014-01-01

    Brain-machine interfaces (BMIs) are artificial systems that aim to restore sensation and movement to severely paralyzed patients. However, previous BMIs enabled only single arm functionality, and control of bimanual movements was a major challenge. Here, we developed and tested a bimanual BMI that enabled rhesus monkeys to control two avatar arms simultaneously. The bimanual BMI was based on the extracellular activity of 374–497 neurons recorded from several frontal and parietal cortical areas of both cerebral hemispheres. Cortical activity was transformed into movements of the two arms with a decoding algorithm called a 5th order unscented Kalman filter (UKF). The UKF is well-suited for BMI decoding because it accounts for both characteristics of reaching movements and their representation by cortical neurons. The UKF was trained either during a manual task performed with two joysticks or by having the monkeys passively observe the movements of avatar arms. Most cortical neurons changed their modulation patterns when both arms were engaged simultaneously. Representing the two arms jointly in a single UKF decoder resulted in improved decoding performance compared with using separate decoders for each arm. As the animals’ performance in bimanual BMI control improved over time, we observed widespread plasticity in frontal and parietal cortical areas. Neuronal representation of the avatar and reach targets was enhanced with learning, whereas pairwise correlations between neurons initially increased and then decreased. These results suggest that cortical networks may assimilate the two avatar arms through BMI control. PMID:24197735

  14. Inter-arm blood pressure differences in pregnant women.

    Science.gov (United States)

    Poon, L C Y; Kametas, N; Strobl, I; Pachoumi, C; Nicolaides, K H

    2008-08-01

    To determine the prevalence of blood pressure inter-arm difference (IAD) in early pregnancy and to investigate its possible association with maternal characteristics. A cross-sectional observational study. Routine antenatal visit in a university hospital. A total of 5435 pregnant women at 11-14 weeks of gestation. Blood pressure was taken from both arms simultaneously with a validated automated device. The presence of inter-arm blood pressure difference of 10 mmHg or more. The IAD in systolic and diastolic blood pressure was 10 mmHg or more in 8.3 and 2.3% of the women, respectively. Systolic IAD was found to be significantly related to systolic blood pressure and pulse pressure, and diastolic IAD was found to be significantly related to maternal age, diastolic blood pressure and pulse pressure. The systolic and diastolic IAD were higher in the hypertensive group compared with the normotensive group and absolute IAD increased with increasing blood pressure. About 31.0 and 23.9% of cases of hypertension would have been underreported if the left arm and the right arm were used, respectively, in measuring the blood pressure. There is a blood pressure IAD in a significant proportion of the pregnant population, and its prevalence increases with increasing blood pressure. By measuring blood pressure only on one arm, there is a one in three chance of underreporting hypertension. Therefore, it would be prudent that during the booking visit blood pressure should be taken in both arms and thus provide guidance for subsequent blood pressure measurements during the course of pregnancy.

  15. Two bullets to the head and an early winter: fate permits Kutuzov to defeat Napoleon at Moscow.

    Science.gov (United States)

    Kushchayev, Sergiy V; Belykh, Evgenii; Fishchenko, Yakiv; Salei, Aliaksei; Teytelboym, Oleg M; Shabaturov, Leonid; Cruse, Mark; Preul, Mark C

    2015-07-01

    General Mikhail Kutuzov (circa 1745-1813) brilliantly repelled Napoleon's invasion of Russia. Honored as a national hero and a savior of Russia, Kutuzov has a unique medical story. He was shot in the head twice while fighting the Turks (1774 and 1788) and survived the serious injuries seemingly against all odds. The first bullet "ran through the head from one temple to the other behind both eyes." The second bullet entered the cheek, destroyed upper teeth, traveled through the head, and exited the occiput. Massot, a French surgeon with the Russian army, wrote after treating Kutuzov's seemingly two mortal wounds: "It must be believed that fate appoints Kutuzov to something great, because he was still alive after two injuries, a death sentence by all the rules of medical science." Aided by Massot's expert surgical technique, Kutuzov lived to become intimately engaged in events that altered world history. His health did, however, suffer significant effects due to the bullet wounds. In 1812, as Napoleon's Grande Armée approached, Kutuzov realized he could not confront Napoleon and he strategically retreated from Moscow, submitting the French to the harsh winter and Russian cavalry. Napoleon's devastated army retreated to Paris, and Kutuzov became the personification of Russian spirit and character. Kutuzov's survival of two nearly mortal head wounds created the legends, additional mystery, and drama surrounding him, not the least astonishing of which was the skilled neurosurgical care that probably saved his life.

  16. Primary design of Si cooling arm structure in ICF cryogenic target

    International Nuclear Information System (INIS)

    Zhang Yong; Yi Yong; Tang Changhuan; Zhang Jicheng

    2013-01-01

    According to the requirement of the cryogenic target system to the Si cooling arm structure, the Si cooling arm was primarily designed based on the USA National Ignition Facility (NIF) target. A new three-dimensional model of Si cooling arm was developed by SolidWorks software, and the simulation and analysis of Si cooling arm in aspect of mechanical property, thermal response and assembly were made based on the model. A law about the effect of the arm length of Si cooling arm and the width and the length of bifurcation on Si cooling arm was achieved. The research may provide the theoretical foundation and reference for the further improvement of cryogenic target. (authors)

  17. SIPRI's new conceptual approach to arms control and disarmament

    International Nuclear Information System (INIS)

    Rotfeld, Adam Daniel

    2000-01-01

    The end of the cold war deprioritized arms control and disarmament, and progress in the field was no longer a measure of relations among the major powers. In that context, the future of arms control and disarmament was discussed at the Nobel Symposium in October 1999. Stockholm International Peace Research Institute (SIPRI) views arms control as an instrument for shaping a new inclusive and cooperative security order. The author questions whether arms control challenges today can and should be resolved in the institutions established and the procedures elaborated in the bipolar framework. (author)

  18. Multi-arm Cost-Effectiveness Analysis (CEA comparing different durations of adjuvant trastuzumab in early breast cancer, from the English NHS payer perspective.

    Directory of Open Access Journals (Sweden)

    Caroline S Clarke

    Full Text Available Trastuzumab improves survival in HER2+ breast cancer patients, with some evidence of adverse cardiac side effects. Current recommendations are to give adjuvant trastuzumab for one year or until recurrence, although trastuzumab treatment for only 9 or 10 weeks has shown similar survival rates to 12-month treatment. We present here a multi-arm joint analysis examining the relative cost-effectiveness of different durations of adjuvant trastuzumab.Network meta-analysis (NMA was used to examine which trials' data to include in the cost-effectiveness analysis (CEA. A network using FinHer (9 weeks vs. zero and BCIRG006 (12 months vs. zero trials offered the only jointly randomisable network so these trials were used in the CEA. The 3-arm CEA compared costs and quality-adjusted life-years (QALYs associated with zero, 9-week and 12-month adjuvant trastuzumab durations in early breast cancer, using a decision tree followed by a Markov model that extrapolated the results to a lifetime time horizon. Pairwise incremental cost-effectiveness ratios (ICERs were also calculated for each pair of regimens and used in budget impact analysis, and the Bucher method was used to check face validity of the findings. Addition of the PHARE trial (6 months vs. 12 months to the network, in order to create a 4-arm CEA including the 6-month regimen, was not possible as late randomisation in this trial resulted in recruitment of a different patient population as evidenced by the NMA findings. The CEA results suggest that 9 weeks' trastuzumab is cost-saving and leads to more QALYs than 12 months', i.e. the former dominates the latter. The cost-effectiveness acceptability frontier (CEAF favours zero trastuzumab at willingness-to-pay levels below £2,500/QALY and treatment for 9 weeks above this threshold. The combination of the NMA and Bucher investigations suggests that the 9-week duration is as efficacious as the 12-month duration for distant-disease-free survival and overall

  19. ARM Enhanced Shortwave Experiment (ARESE) Solar Radiation Data

    Data.gov (United States)

    National Aeronautics and Space Administration — The ARM Enhanced Shortwave Experiment (ARESE) was conducted at the Department of Energy's ARM Southern Great Plains (SGP) Central Facility between September 22, 1995...

  20. Rosoboroneksport: Arms Sales and the Structure of Russian Defense Industry

    National Research Council Canada - National Science Library

    Blank, Stephen J

    2007-01-01

    In August 2006, the U.S. Government imposed sanctions on Russian arms sellers and producers, Rosoboroneksport, Russia's main arms-selling agency, and Sukhoi, which manufactures aircraft, because of their arms sales to Iran...

  1. Changes in the bilateral pulse transit time difference with a moving arm.

    Science.gov (United States)

    Jiang, Xinge; Wei, Shoushui; Zheng, Dingchang; Huang, Peng; Liu, Chengyu

    2018-04-20

    Changes of pulse transit time (PTT) induced by arm position were studied for unilateral arm. However, consistency of the PTT changes was not validated for both arm sides. We aimed to quantify the PTT changes between horizontal and non-horizontal positions from right arm and left arm in order to explore the consistency of both arms. Twenty-four normal subjects aged between 21 and 50 (14 male and 10 female) years were enrolled. Left and right radial artery pulses were synchronously recorded from 24 healthy subjects with one arm (left or right) at five angles (90∘, 45∘, 0∘, -45∘ and -90∘) and the other arm at the horizontal level (0∘) for reference. The overall mean PTT changes at the five angles (from 90∘ to -90∘) in the left arm (right as reference) were 16.1, 12.3, -0.5, -2.5 and -2.6 ms, respectively, and in the right arm (left as reference) were 18.0, 12.6, 1.6, -1.6 and -2.0 ms, respectively. Obvious differences were not found in the PTT changes between the two arms (left arm moving or right arm moving) under each of the five different positions (all P> 0.05).

  2. The position of the arm during blood pressure measurement in sitting position.

    Science.gov (United States)

    Adiyaman, Ahmet; Verhoeff, Rutger; Lenders, Jacques W M; Deinum, Jaap; Thien, Theo

    2006-12-01

    Determining the influence of the position of the arm on blood pressure measurement in the sitting position. Blood pressure of 128 individuals (the majority being treated hypertensive patients) visiting the outpatient clinic was measured simultaneously on both arms with arms in two different positions. First, both arms were placed at the chair support level and blood pressure was measured three times on both arms after 10 min of rest. Subsequently, while still remaining in the same sitting position, five blood pressure measurements were made simultaneously at both arms with one arm placed on the desk and one arm placed and supported at heart level (mid-sternal). The arm placed at heart level served as the reference arm. The choice of which arm was placed at desk level and which arm was placed at heart level was randomized. Both at desk level and at chair support level, mean (+/-SD) systolic and diastolic blood pressures were higher than blood pressure at heart level by 6.1/5.7+/-4.6/3.1 and 9.3/9.4+/-5.4/3.4 mmHg, respectively. The effect of the height differences between the arm positions on the blood pressure readings was smaller than predicted (0.49 mmHg/cm systolic and 0.47 mmHg/cm diastolic). No significant correlation was found between blood pressure difference in the different arm positions (desk and heart level) and age, sex, weight or baseline blood pressure. Different arm positions below heart level have significant effects on blood pressure readings. The leading guidelines about arm position during blood pressure measurement are not in accordance with the arm position used in the Framingham study, the most frequently used study for risk estimations.

  3. Homosexuality in the Dutch Armed Forces 2006

    NARCIS (Netherlands)

    Anna Adolfsen; Saskia Keuzenkamp; m.m.v. Linda Mans

    2006-01-01

    Original title: Uniform uit de kast. This study looks at the attitudes of defence personnel to homosexuality. How do members of the military view homosexual colleagues? Can gays and lesbians working in the armed forces be open about their sexual preferences? Do they regard the armed forces as

  4. TOWARDS UNIFORM RULES FOR ARMED CONFLICTS Pieter ...

    African Journals Online (AJOL)

    the two Additional Protocols that followed in 1977, divide armed conflict into two legal categories: ... Wounded, Sick and Shipwrecked Members of Armed Forces at Sea. Third Convention ... Nationalist China; ibid 116. ... 17 Pictet op cit 43; Junod, S 'Additional Protocol II: History and Scope' (1983) 33 The. American ...

  5. Limited consensus around ARM information protection practices1

    African Journals Online (AJOL)

    KATUU, Shadrack

    surrounding Information Protection (IP) has been ... compares IP and ARM information protection through .... decision-making methodology used to help ... and differing requirements of institutions into account. ARM literature is prescriptive with.

  6. Nudging Armed Groups: How Civilians Transmit Norms of Protection

    Directory of Open Access Journals (Sweden)

    Oliver Kaplan

    2013-12-01

    Full Text Available What are the varying roles that norms play to either enable or constrain violence in armed conflict settings? The article examines this question by drawing on experiences from communities and armed groups in Colombia and Syria. It begins by presenting an explanation of how norms of violence and nonviolence may arise within communities and influence the behavior of civilian residents, reducing the chances of them becoming involved with armed groups. It then considers how civilian communities can transmit those same norms, shared understandings, and patterns of interaction to the ranks of illegal armed groups and subsequently shape their decisions about the use of violence against civilians. The author argues that civilians may be better positioned to promote the principles codified in International Humanitarian Law than international humanitarian organizations because they have closer contact with irregular armed actors and are viewed with greater legitimacy. The analysis illustrates that to better understand civilian protection mechanisms it is essential to study the interactions between communities and armed actors.

  7. Cryo-scanning electron microscopy investigation of the Octopus Vulgaris arm structures for the design of an octopus-like arm artefact.

    Science.gov (United States)

    Minnocci, Antonio; Cianchetti, Matteo; Mazzolai, Barbara; Sebastiani, Luca; Laschi, Cecilia

    2015-12-01

    Octopus vulgaris is a cephalopod of the Octopodidae family. It has four pairs of arms and two rows of suckers which perform many functions, including bending and elongation. For this reason the octopus was chosen as model to develop a new generation of soft-body robots. In order to explain some of the fine structures of the octopus arm in relation to its specific ability, we examined the external and internal structures of O. vulgaris arms in a frozen-hydrated state using cryo-scanning electron microscopy. The arms showed skin with a very complex design that is useful to elongation, and a pore pattern distribution on their surface which is functional to cutaneous oxygen uptake. The analysis of freeze-fractured frozen-hydrated arm samples allowed us to describe the developmental differences in the relative proportion of the areas of axial nerve cord, intrinsic and extrinsic musculature, in relation to the growth of the arms and of the increase in functional capability. In the suckers, we analyzed the shedding mechanisms in the outer part of the infundibulum and described the outer and inner characteristics of the denticles, showing in detail their pore system, which is fundamental for their ability to explore the environment. These results are discussed by considering their possible application in the design of new octopus-like artefacts, which will be able to take advantage of some of these ultrastructure characteristics and achieve advanced bioinspired functionalities. © 2015 Wiley Periodicals, Inc.

  8. Rapid Generation of Personalized HRTFs

    DEFF Research Database (Denmark)

    Huttunen, Tomi; Vanne, Antti; Harder, Stine

    Numerical simulations offer a viable alternative to measurements for generating personalized head-related transfer functions (HRTFs). The fast multipole boundary element method (FM-BEM) is a popular method for simulating the HRTFs since it requires a surface mesh of the head (and torso) only....... The FM-BEM simulation of the HRTF at a single frequency can be computed in a few minutes. Utilizing cloud computing, the entire audible frequency range can be simulated in less than an hour. A bottleneck in the fast acquisition of the personalized HRTFs has been the complexity of generating good quality...... head models for the simulation. We compare three photography based geometry acquisition methods, ranging from a system of 52 cameras to a method using a single mobile phone camera only....

  9. Randomized phase III trial (GORTEC 98-03) comparing re-irradiation plus chemotherapy versus methotrexate in patients with recurrent or a second primary head and neck squamous cell carcinoma, treated with a palliative intent

    International Nuclear Information System (INIS)

    Tortochaux, Jacques; Tao Yungan; Tournay, Elodie; Lapeyre, Michel; Lesaunier, Francois; Bardet, Etienne; Janot, Francois; Lusinchi, Antoine; Benhamou, Ellen; Bontemps, Patrick; Maingon, Philippe; Calais, Gilles; Daly-Schveitzer, Nicolas; Verrelle, Pierre; Bourhis, Jean

    2011-01-01

    Purpose: This randomized phase III trial investigated the potential benefit of concurrent re-irradiation, fluorouracil and hydroxyurea versus methotrexate for patients treated with palliative intent for recurrent or second primary head and neck squamous cell carcinoma (HNSCC) in previously irradiated area. Patients and methods: Patients with recurrent HNSCC or a second primary not amenable to curative-intent treatment were randomized to the R-RT arm (concurrent re-irradiation, fluorouracil and hydroxyurea) or to the Ch-T arm (methotrexate). The primary endpoint was overall survival (OS). Due to a very slow accrual, the trial was closed after inclusion of 57 patients. Results: Fifty-seven patients were included. All patients died in the two arms with a maximal follow-up of 5 years. Although four complete responses were achieved in R-RT arm, (none in Ch-T arm) re-irradiation did not improve OS compared with methotrexate (23% versus 22% at 1 year, NS). Sixteen patients experienced clinical grade ≥3 late toxicities (>6 months), 11 in R-RT arm and five in Ch-T arm. Conclusions: Premature discontinuation of the trial did not allow us to draw firm conclusions. However, there was no suggestion that concurrent re-irradiation, fluorouracil and hydroxyurea improved OS compared to methotrexate alone in patients treated with palliative intent for a recurrent or second primary HNSCC.

  10. Genetic analysis and fine mapping of LH1 and LH2, a set of complementary genes controlling late heading in rice (Oryza sativa L.).

    Science.gov (United States)

    Liu, Shuang; Wang, Feng; Gao, Li Jun; Li, Jin Hua; Li, Rong Bai; Gao, Han Liang; Deng, Guo Fu; Yang, Jin Shui; Luo, Xiao Jin

    2012-12-01

    Heading date in rice (Oryza sativa L.) is a critical agronomic trait with a complex inheritance. To investigate the genetic basis and mechanism of gene interaction in heading date, we conducted genetic analysis on segregation populations derived from crosses among the indica cultivars Bo B, Yuefeng B and Baoxuan 2. A set of dominant complementary genes controlling late heading, designated LH1 and LH2, were detected by molecular marker mapping. Genetic analysis revealed that Baoxuan 2 contains both dominant genes, while Bo B and Yuefeng B each possess either LH1 or LH2. Using larger populations with segregant ratios of 3 : 1, we fine-mapped LH1 to a 63-kb region near the centromere of chromosome 7 flanked by markers RM5436 and RM8034, and LH2 to a 177-kb region on the short arm of chromosome 8 between flanking markers Indel22468-3 and RM25. Some candidate genes were identified through sequencing of Bo B and Yuefeng B in these target regions. Our work provides a solid foundation for further study on gene interaction in heading date and has application in marker-assisted breeding of photosensitive hybrid rice in China.

  11. Galaxy Zoo: constraining the origin of spiral arms

    Science.gov (United States)

    Hart, Ross E.; Bamford, Steven P.; Keel, William C.; Kruk, Sandor J.; Masters, Karen L.; Simmons, Brooke D.; Smethurst, Rebecca J.

    2018-05-01

    Since the discovery that the majority of low-redshift galaxies exhibit some level of spiral structure, a number of theories have been proposed as to why these patterns exist. A popular explanation is a process known as swing amplification, yet there is no observational evidence to prove that such a mechanism is at play. By using a number of measured properties of galaxies, and scaling relations where there are no direct measurements, we model samples of SDSS and S4G spiral galaxies in terms of their relative halo, bulge and disc mass and size. Using these models, we test predictions of swing amplification theory with respect to directly measured spiral arm numbers from Galaxy Zoo 2. We find that neither a universal cored or cuspy inner dark matter profile can correctly predict observed numbers of arms in galaxies. However, by invoking a halo contraction/expansion model, a clear bimodality in the spiral galaxy population emerges. Approximately 40 per cent of unbarred spiral galaxies at z ≲ 0.1 and M* ≳ 1010M⊙ have spiral arms that can be modelled by swing amplification. This population display a significant correlation between predicted and observed spiral arm numbers, evidence that they are swing amplified modes. The remainder are dominated by two-arm systems for which the model predicts significantly higher arm numbers. These are likely driven by tidal interactions or other mechanisms.

  12. Using heart rate to prescribe physical exercise during head-out water immersion.

    Science.gov (United States)

    Kruel, Luiz F M; Peyré-Tartaruga, Leonardo A; Coertjens, Marcelo; Dias, Adriana B C; Da Silva, Rafael C; Rangel, Antônio C B

    2014-01-01

    The purpose of this study was to compare and correlate the effect of age group, sex, depth of water immersion, and the heart rate (HR) assessed out of the water on the HR behavior in individuals subjected to head-out water immersion. A total of 395 healthy individuals of both sexes, aged between 07 and 75 years, underwent vertical head-out water immersion. Heart rate was assessed out of the water in the supine and orthostatic (OHR) positions and at immersion depths corresponding to the ankle, knee, hip, umbilicus, xiphoid process, acromion, neck, and also the neck with the arms out of the water. The formula (ΔHR = OHR - HR immersion depth) was used to calculate the reduction in HR at each immersion depth. No age-based or sex-based differences in HR were found. The greater the depth of the water, the greater was the decrease in HR (p water-based exercise intensity performed during vertical immersion: OHR should be measured before the individual entering the aquatic environment; ΔHR should be measured according to the depth at which exercise is to be performed, and we suggest an adaptation to Karvonen's HRmax prediction formula (predicted HRmax: 220 - age - ΔHR) to prescribe and control the intensity of the exercise performed during vertical immersion.

  13. Responses and Injuries to PMHS in Side-Facing and Oblique Seats in Horizontal Longitudinal Sled Tests per FAA Emergency Landing Conditions.

    Science.gov (United States)

    Humm, John R; Yoganandan, Narayan; Pintar, Frank A; DeWeese, Richard L; Moorcroft, David M; Taylor, Amanda M; Peterson, Brian

    2016-11-01

    The objective of the present exploratory study is to understand occupant responses in oblique and side-facing seats in the aviation environment, which are increasingly installed in modern aircrafts. Sled tests were conducted using intact Post Mortem Human Surrogates (PMHS) seated in custom seats approximating standard aircraft geometry. End conditions were selected to represent candidate aviation seat and restraint configurations. Three-dimensional head center-of-gravity linear accelerations, head angular velocities, and linear accelerations of the T1, T6, and T12 spinous processes, and sacrum were obtained. Three-dimensional kinematics relative to the seat were obtained from retroreflective targets attached to the head, T1, T6, T12, and sacrum. All specimens sustained spinal injuries, although variations existed by vertebral level. While the tension mechanism was associated with cervical spine injuries, complex distraction-coupled with bending and tension was attributed to thoracolumbar spine injuries. Skeletal fractures to the ribcage were attributed to compression induced by the restraint from the seatbelt, the presence of the armrest, and/or severe motions of the unconstrained torso. Pelvic injuries were also attributed to restraint offered by the lap belt on the accelerating torso-pelvis complex in the absence of the armrest. Lower extremity injuries occurred due to the unconstrained motion (flailing mechanism). These results serve as an initial dataset to understand the kinematics of different body regions, injuries and patterns, and potential injury mechanisms describing PMHS responses in the aviation environment.

  14. Grand-design Spiral Arms in a Young Forming Circumstellar Disk

    Energy Technology Data Exchange (ETDEWEB)

    Tomida, Kengo; Lin, Chia Hui [Department of Earth and Space Science, Osaka University, Toyonaka, Osaka 560-0043 (Japan); Machida, Masahiro N. [Department of Earth and Planetary Sciences, Faculty of Sciences, Kyushu University, Nishi-ku, Fukuoka 819-0395 (Japan); Hosokawa, Takashi [Department of Physics, Kyoto University, Sakyo-ku, Kyoto 606-8502 (Japan); Sakurai, Yuya, E-mail: tomida@vega.ess.sci.osaka-u.ac.jp [Department of Physics, The University of Tokyo, Tokyo 113-0033 (Japan)

    2017-01-20

    We study formation and long-term evolution of a circumstellar disk in a collapsing molecular cloud core using a resistive magnetohydrodynamic simulation. While the formed circumstellar disk is initially small, it grows as accretion continues, and its radius becomes as large as 200 au toward the end of the Class-I phase. A pair of grand-design spiral arms form due to gravitational instability in the disk, and they transfer angular momentum in the highly resistive disk. Although the spiral arms disappear in a few rotations as expected in a classical theory, new spiral arms form recurrently as the disk, soon becoming unstable again by gas accretion. Such recurrent spiral arms persist throughout the Class-0 and I phases. We then perform synthetic observations and compare our model with a recent high-resolution observation of a young stellar object Elias 2–27, whose circumstellar disk has grand-design spiral arms. We find good agreement between our theoretical model and the observation. Our model suggests that the grand-design spiral arms around Elias 2–27 are consistent with material arms formed by gravitational instability. If such spiral arms commonly exist in young circumstellar disks, it implies that young circumstellar disks are considerably massive and gravitational instability is the key process of angular momentum transport.

  15. Grand-design Spiral Arms in a Young Forming Circumstellar Disk

    International Nuclear Information System (INIS)

    Tomida, Kengo; Lin, Chia Hui; Machida, Masahiro N.; Hosokawa, Takashi; Sakurai, Yuya

    2017-01-01

    We study formation and long-term evolution of a circumstellar disk in a collapsing molecular cloud core using a resistive magnetohydrodynamic simulation. While the formed circumstellar disk is initially small, it grows as accretion continues, and its radius becomes as large as 200 au toward the end of the Class-I phase. A pair of grand-design spiral arms form due to gravitational instability in the disk, and they transfer angular momentum in the highly resistive disk. Although the spiral arms disappear in a few rotations as expected in a classical theory, new spiral arms form recurrently as the disk, soon becoming unstable again by gas accretion. Such recurrent spiral arms persist throughout the Class-0 and I phases. We then perform synthetic observations and compare our model with a recent high-resolution observation of a young stellar object Elias 2–27, whose circumstellar disk has grand-design spiral arms. We find good agreement between our theoretical model and the observation. Our model suggests that the grand-design spiral arms around Elias 2–27 are consistent with material arms formed by gravitational instability. If such spiral arms commonly exist in young circumstellar disks, it implies that young circumstellar disks are considerably massive and gravitational instability is the key process of angular momentum transport.

  16. The Importance of Neurogenic Inflammation in Blast-Induced Neurotrauma

    Science.gov (United States)

    2014-05-01

    physiological dose). Even though correlation time and other phenomena are responsible for the curves behavior (intensity versus concentration is graphed...animal and that potential rarefactions from the tube opening were minimized. The neck, head, torso, and abdomen of the animal were fixed to the animal...Bowen curve of blast lethality and lung damage for mice (Bowen et al., 1968b; Richmond et al., 1967) and tested in preliminary experiments (not shown

  17. The globalization of the arms industry: The next proliferation challenge

    Energy Technology Data Exchange (ETDEWEB)

    Bitzinger, R.A.

    1994-12-31

    The globalization of the arms industry entails a significant shift away from traditional, single-country patterns of weapons production toward internationalization of the development, production, and marketing of arms. While wholly indigenous armaments production may be on the decline, multinational arms production - through collaboration on individual weapon systems and increasingly via interfirm linkages across the international arms industry - appears actually to be expanding. In several instances, in fact, multinational armaments production is increasingly supplementing or even supplanting indigenous or autonomous weapons production or arms imports. The emergence of an increasingly transnational defense technology and industrial base is fundamentally affecting the shape and content of much of the global arms trade. This changing defense market, in turn, will have a profound impact on a number of national security issues concerning the Western industrialized nations. 3 figs., 2 tabs.

  18. Development of the OPESCOPE mobile C-arm system

    International Nuclear Information System (INIS)

    Tsuji, Hisao; Kadowaki, Toshio; Shimizu, Yasumitsu

    1994-01-01

    A new mobile C-arm X-ray fluoroscopy system called the 'OPESCOPE' equipped with a CCD TV camera and high-definition Image Intensifier has been developed. All the cables for the I.I. and X-ray generator are held inside the C-arm to prevent interference with operation and the C-arm is locked electromagnetically. Moreover, the C-arm is spring counterbalanced in the vertical motion axis. These features enable smooth positioning and uncluttered operation. The X-ray generator uses a high-frequency inverter designed to assure noiseless operation and a compact size. With the new DFS-700 videoprocessor unit being combined, clearer, more informative images can be obtained. In addition to its inherent portability this unit can be upgraded in DSA function to allow angiographic examinations in the surgical theater. (author)

  19. Inter-arm blood pressure differences in young, healthy patients.

    Science.gov (United States)

    Grossman, Alon; Prokupetz, Alex; Gordon, Barak; Morag-Koren, Nira; Grossman, Ehud

    2013-08-01

    The prevalence and magnitude of inter-arm BP difference (IAD) in young healthy patients is not well characterized. Flight academy applicants and designated aviators undergo annual evaluation that includes blood pressure (BP) measurement on both arms. All BP measurements performed from January 1, 2012, to April 30, 2012, were recorded and IAD was calculated. Results were compared between patients in whom BP was initially measured in the right arm (group 1), those in whom BP was initially measured in the left arm (group 2), and those in whom the arm in which BP was initially measured was not recorded (group 3). A total of 877 healthy patients had BP measured during the study period. In the entire group, mean systolic BP was the same in both arms. Absolute IAD was 5.6±5.5 mm Hg for systolic and 4.7±4.5 mm Hg for diastolic BP. IAD >10 mm Hg was recorded in 111 (12.6%) and 77 (8.8%) patients for systolic and diastolic BP, respectively. IAD was the same in the 3 groups and was unrelated to age, body mass index, and heart rate, but was related to systolic BP. IAD is common in young healthy patients, is not dependent on which arm was measured first, and unrelated to age, body mass index, and heart rate. © 2013 Wiley Periodicals, Inc.

  20. Trigonometric parallaxes of star forming regions in the Scutum spiral arm

    International Nuclear Information System (INIS)

    Sato, M.; Wu, Y. W.; Immer, K.; Zhang, B.; Sanna, A.; Brunthaler, A.; Menten, K. M.; Reid, M. J.; Dame, T. M.

    2014-01-01

    We report measurements of trigonometric parallaxes for six high-mass star-forming regions in the Scutum spiral arm of the Milky Way as part of the BeSSeL Survey. Combining our measurements with 10 previous measurements from the BeSSeL Survey yields a total sample of 16 sources in the Scutum arm with trigonometric parallaxes in the Galactic longitude range from 5° to 32°. Assuming a logarithmic spiral model, we estimate a pitch angle of 19.°8 ± 3.°1 for the Scutum arm, which is larger than pitch angles reported for other spiral arms. The high pitch angle of the arm may be due to the arm's proximity to the Galactic bar. The Scutum arm sources show an average peculiar motion of 4 km s –1 slower than the Galactic rotation and 8 km s –1 toward the Galactic center. While the direction of this non-circular motion has the same sign as determined for sources in other spiral arms, the motion toward the Galactic center is greater for the Scutum arm sources.

  1. Head Lice

    Science.gov (United States)

    ... nits. You should also use hot water to wash any bed linens, towels, and clothing recently worn by the person who had head lice. Vacuum anything that can’t be washed, such as the couch, carpets, your child’s car seat, and any stuffed animals. Because head lice ...

  2. CATALOG OF OBSERVED TANGENTS TO THE SPIRAL ARMS IN THE MILKY WAY GALAXY

    Energy Technology Data Exchange (ETDEWEB)

    Vallée, Jacques P., E-mail: jacques.vallee@nrc-cnrc.gc.ca [Herzberg Astrophysics, National Research Council Canada, National Science Infrastructure portfolio, 5071 West Saanich Road, Victoria, BC, V9E 2E7 (Canada)

    2014-11-01

    From the Sun's location in the Galactic disk, one can use different arm tracers (CO, H I, thermal or ionized or relativistic electrons, masers, cold and hot dust, etc.) to locate a tangent to each spiral arm in the disk of the Milky Way. We present a master catalog of the astronomically observed tangents to the Galaxy's spiral arms, using different arm tracers from the literature. Some arm tracers can have slightly divergent results from several papers, so a mean value is taken—see the Appendix for CO, H II, and masers. The catalog of means currently consists of 63 mean tracer entries, spread over many arms (Carina, Crux-Centaurus, Norma, Perseus origin, near 3 kpc, Scutum, Sagittarius), stemming from 107 original arm tracer entries. Additionally, we updated and revised a previous statistical analysis of the angular offset and linear separation from the mid-arm for each different mean arm tracer. Given enough arm tracers, and summing and averaging over all four spiral arms, one could determine if arm tracers have separate and parallel lanes in the Milky Way. This statistical analysis allows a cross-cut of a Galactic spiral arm to be made, confirming a recent discovery of a linear separation between arm tracers. Here, from the mid-arm's CO to the inner edge's hot dust, the arm halfwidth is about 340 pc; doubling would yield a full arm width of 680 pc. We briefly compare these observations with the predictions of many spiral arm theories, notably the density wave theory.

  3. CATALOG OF OBSERVED TANGENTS TO THE SPIRAL ARMS IN THE MILKY WAY GALAXY

    International Nuclear Information System (INIS)

    Vallée, Jacques P.

    2014-01-01

    From the Sun's location in the Galactic disk, one can use different arm tracers (CO, H I, thermal or ionized or relativistic electrons, masers, cold and hot dust, etc.) to locate a tangent to each spiral arm in the disk of the Milky Way. We present a master catalog of the astronomically observed tangents to the Galaxy's spiral arms, using different arm tracers from the literature. Some arm tracers can have slightly divergent results from several papers, so a mean value is taken—see the Appendix for CO, H II, and masers. The catalog of means currently consists of 63 mean tracer entries, spread over many arms (Carina, Crux-Centaurus, Norma, Perseus origin, near 3 kpc, Scutum, Sagittarius), stemming from 107 original arm tracer entries. Additionally, we updated and revised a previous statistical analysis of the angular offset and linear separation from the mid-arm for each different mean arm tracer. Given enough arm tracers, and summing and averaging over all four spiral arms, one could determine if arm tracers have separate and parallel lanes in the Milky Way. This statistical analysis allows a cross-cut of a Galactic spiral arm to be made, confirming a recent discovery of a linear separation between arm tracers. Here, from the mid-arm's CO to the inner edge's hot dust, the arm halfwidth is about 340 pc; doubling would yield a full arm width of 680 pc. We briefly compare these observations with the predictions of many spiral arm theories, notably the density wave theory

  4. Neck and arm pain syndromes

    DEFF Research Database (Denmark)

    de las Peñas, César Fernández; Cleland, Joshua; Huijbregts, Peter

    approaches.It uniquely addresses the expanding role of the various health care professions which require increased knowledge and skills in screening for contra-indications and recognizing the need for medical-surgical referral. Neck and Arm Pain Syndromes also stresses the integration of experiential......The first of its kind, Neck and Arm Pain Syndromes is a comprehensive evidence- and clinical-based book, covering research-based diagnosis, prognosis and management of neuromusculoskeletal pathologies and dysfunctions of the upper quadrant, including joint, muscle, myofascial and neural tissue...... of the most commonly seen pain syndromes in clinical practice over 800 illustrations demonstrating examination procedures and techniques....

  5. Structure of the S6 spirel arm in the Andromeda galaxy

    International Nuclear Information System (INIS)

    Efremov, Yu.N.

    1982-01-01

    The distribution of stars across the spiral arm S6 in M 31 within Baade's Field 4 is investigated. It is found that the brightest stars are concentrated to the middle line of the arm where the maximal star density is also observed. The symmetry of the arm S6 may be explained by its position near the corotation radius that followed from the spiral pattern velocity Ωsub(P) approximately 10 km/s kpc determined by the age gradient in the arm S4. The similarity between the structure of the arm S6 and that of the spiral arms near the Sun is pointed out [ru

  6. Current Sharing Analysis of Arm Prototype for ITER PF Converter Bridge

    International Nuclear Information System (INIS)

    Li Jinchao; Song Zhiquan; Xu Liuwei; Fu Peng; Guo Bin; Li Sen; Dong Lin; Wang Min

    2014-01-01

    A bridge arm prototype of ITER poloidal field (PF) converter modules has been designed and fabricated. Non-cophase counter parallel connection is chosen as the arm structure of the prototype. Among all factors affecting current sharing, arm structure is the main one. During the design of the arm prototype, a novel method based on inductance matrixes is employed to improve the current sharing of the bridge arm. The test results on the prototype show that the current sharing performance of the arm prototype is much better than relevant design requirement, and that the matrix method is very effective to analyze and solve the current sharing problems of thyristor converters

  7. CHARACTERIZING SPIRAL ARM AND INTERARM STAR FORMATION

    Energy Technology Data Exchange (ETDEWEB)

    Kreckel, K.; Schinnerer, E.; Meidt, S. [Max Planck Institut für Astronomie, Königstuhl 17, D-69117 Heidelberg (Germany); Blanc, G. A. [Departamento de Astronomía, Universidad de Chile, Camino del Observatorio 1515, Las Condes, Santiago (Chile); Groves, B. [Research School of Astronomy and Astrophysics, Australian National University, Canberra, ACT 2611 (Australia); Adamo, A. [Department of Astronomy, The Oskar Klein Centre, Stockholm University, AlbaNova University Centre, SE-106 91 Stockholm (Sweden); Hughes, A., E-mail: kreckel@mpia.de [CNRS, IRAP, 9 Av. du Colonel Roche, BP 44346, F-31028 Toulouse cedex 4 (France)

    2016-08-20

    Interarm star formation contributes significantly to a galaxy’s star formation budget and provides an opportunity to study stellar birthplaces unperturbed by spiral arm dynamics. Using optical integral field spectroscopy of the nearby galaxy NGC 628 with VLT/MUSE, we construct H α maps including detailed corrections for dust extinction and stellar absorption to identify 391 H ii regions at 35 pc resolution over 12 kpc{sup 2}. Using tracers sensitive to the underlying gravitational potential, we associate H ii regions with either arm (271) or interarm (120) environments. Using our full spectral coverage of each region, we find that most physical properties (luminosity, size, metallicity, ionization parameter) of H ii regions are independent of environment. We calculate the fraction of H α luminosity due to the background of diffuse ionized gas (DIG) contaminating each H ii region, and find the DIG surface brightness to be higher within H ii regions than in the surroundings, and slightly higher within arm H ii regions. Use of the temperature-sensitive [S ii]/H α line ratio instead of the H α surface brightness to identify the boundaries of H ii regions does not change this result. Using the dust attenuation as a tracer of the gas, we find depletion times consistent with previous work (2 × 10{sup 9} yr) with no differences between the arm and interarm, but this is very sensitive to the DIG correction. Unlike molecular clouds, which can be dynamically affected by the galactic environment, we see fairly consistent properties of H ii regions in both arm and interarm environments. This suggests either a difference in star formation and feedback in arms or a decoupling of dense star-forming clumps from the more extended surrounding molecular gas.

  8. Effect of arm swing strategy on local dynamic stability of human gait.

    Science.gov (United States)

    Punt, Michiel; Bruijn, Sjoerd M; Wittink, Harriet; van Dieën, Jaap H

    2015-02-01

    Falling causes long term disability and can even lead to death. Most falls occur during gait. Therefore improving gait stability might be beneficial for people at risk of falling. Recently arm swing has been shown to influence gait stability. However at present it remains unknown which mode of arm swing creates the most stable gait. To examine how different modes of arm swing affect gait stability. Ten healthy young male subjects volunteered for this study. All subjects walked with four different arm swing instructions at seven different gait speeds. The Xsens motion capture suit was used to capture gait kinematics. Basic gait parameters, variability and stability measures were calculated. We found an increased stability in the medio-lateral direction with excessive arm swing in comparison to normal arm swing at all gait speeds. Moreover, excessive arm swing increased stability in the anterior-posterior and vertical direction at low gait speeds. Ipsilateral and inphase arm swing did not differ compared to a normal arm swing. Excessive arm swing is a promising gait manipulation to improve local dynamic stability. For excessive arm swing in the ML direction there appears to be converging evidence. The effect of excessive arm swing on more clinically relevant groups like the more fall prone elderly or stroke survivors is worth further investigating. Excessive arm swing significantly increases local dynamic stability of human gait. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. Radiologic head CT interpretation errors in pediatric abusive and non-abusive head trauma patients

    International Nuclear Information System (INIS)

    Kralik, Stephen F.; Finke, Whitney; Wu, Isaac C.; Ho, Chang Y.; Hibbard, Roberta A.; Hicks, Ralph A.

    2017-01-01

    Pediatric head trauma, including abusive head trauma, is a significant cause of morbidity and mortality. The purpose of this research was to identify and evaluate radiologic interpretation errors of head CTs performed on abusive and non-abusive pediatric head trauma patients from a community setting referred for a secondary interpretation at a tertiary pediatric hospital. A retrospective search identified 184 patients <5 years of age with head CT for known or potential head trauma who had a primary interpretation performed at a referring community hospital by a board-certified radiologist. Two board-certified fellowship-trained neuroradiologists at an academic pediatric hospital independently interpreted the head CTs, compared their interpretations to determine inter-reader discrepancy rates, and resolved discrepancies to establish a consensus second interpretation. The primary interpretation was compared to the consensus second interpretation using the RADPEER trademark scoring system to determine the primary interpretation-second interpretation overall and major discrepancy rates. MRI and/or surgical findings were used to validate the primary interpretation or second interpretation when possible. The diagnosis of abusive head trauma was made using clinical and imaging data by a child abuse specialist to separate patients into abusive head trauma and non-abusive head trauma groups. Discrepancy rates were compared for both groups. Lastly, primary interpretations and second interpretations were evaluated for discussion of imaging findings concerning for abusive head trauma. There were statistically significant differences between primary interpretation-second interpretation versus inter-reader overall and major discrepancy rates (28% vs. 6%, P=0.0001; 16% vs. 1%, P=0.0001). There were significant differences in the primary interpretation-second interpretation overall and major discrepancy rates for abusive head trauma patients compared to non-abusive head trauma

  10. Radiologic head CT interpretation errors in pediatric abusive and non-abusive head trauma patients

    Energy Technology Data Exchange (ETDEWEB)

    Kralik, Stephen F.; Finke, Whitney; Wu, Isaac C.; Ho, Chang Y. [Indiana University School of Medicine, Department of Radiology and Imaging Sciences, Indianapolis, IN (United States); Hibbard, Roberta A.; Hicks, Ralph A. [Indiana University School of Medicine, Department of Pediatrics, Section of Child Protection Programs, Indianapolis, IN (United States)

    2017-07-15

    Pediatric head trauma, including abusive head trauma, is a significant cause of morbidity and mortality. The purpose of this research was to identify and evaluate radiologic interpretation errors of head CTs performed on abusive and non-abusive pediatric head trauma patients from a community setting referred for a secondary interpretation at a tertiary pediatric hospital. A retrospective search identified 184 patients <5 years of age with head CT for known or potential head trauma who had a primary interpretation performed at a referring community hospital by a board-certified radiologist. Two board-certified fellowship-trained neuroradiologists at an academic pediatric hospital independently interpreted the head CTs, compared their interpretations to determine inter-reader discrepancy rates, and resolved discrepancies to establish a consensus second interpretation. The primary interpretation was compared to the consensus second interpretation using the RADPEER trademark scoring system to determine the primary interpretation-second interpretation overall and major discrepancy rates. MRI and/or surgical findings were used to validate the primary interpretation or second interpretation when possible. The diagnosis of abusive head trauma was made using clinical and imaging data by a child abuse specialist to separate patients into abusive head trauma and non-abusive head trauma groups. Discrepancy rates were compared for both groups. Lastly, primary interpretations and second interpretations were evaluated for discussion of imaging findings concerning for abusive head trauma. There were statistically significant differences between primary interpretation-second interpretation versus inter-reader overall and major discrepancy rates (28% vs. 6%, P=0.0001; 16% vs. 1%, P=0.0001). There were significant differences in the primary interpretation-second interpretation overall and major discrepancy rates for abusive head trauma patients compared to non-abusive head trauma

  11. “Pharyngocise”: Randomized Controlled Trial of Preventative Exercises to Maintain Muscle Structure and Swallowing Function During Head-and-Neck Chemoradiotherapy

    International Nuclear Information System (INIS)

    Carnaby-Mann, Giselle; Crary, Michael A.; Schmalfuss, Ilona; Amdur, Robert

    2012-01-01

    Purpose: Dysphagia after chemoradiotherapy is common. The present randomized clinical trial studied the effectiveness of preventative behavioral intervention for dysphagia compared with the “usual care.” Methods and Materials: A total of 58 head-and-neck cancer patients treated with chemoradiotherapy were randomly assigned to usual care, sham swallowing intervention, or active swallowing exercises (pharyngocise). The intervention arms were treated daily during chemoradiotherapy. The primary outcome measure was muscle size and composition (determined by T 2 -weighted magnetic resonance imaging). The secondary outcomes included functional swallowing ability, dietary intake, chemosensory function, salivation, nutritional status, and the occurrence of dysphagia-related complications. Results: The swallowing musculature (genioglossus, hyoglossuss, and mylohyoid) demonstrated less structural deterioration in the active treatment arm. The functional swallowing, mouth opening, chemosensory acuity, and salivation rate deteriorated less in the pharyngocise group. Conclusion: Patients completing a program of swallowing exercises during cancer treatment demonstrated superior muscle maintenance and functional swallowing ability.

  12. The European Union and armed drones: framing the debate

    DEFF Research Database (Denmark)

    Martins, Bruno Oliveira

    2015-01-01

    Armed drones are an issue extremely relevant for the EU. The recent emergence of targeted killings as a common counter-terrorism technique, the existence of several EU member states using armed and surveillance drones in military scenarios, the presence of member states troops in areas where armed...... drones have been active, the US use of European-originated intelligence to execute targeted killings, and the broader status of international law, are developments that illustrate the importance of the topic. Yet, the EU still does not have an official position on armed drones. In 2014 the European...... Parliament recognized that this is problematic, adopting a Resolution that expressed “grave concern over the use of armed drones outside the international legal framework” and that urged the EU to “develop an appropriate policy response at both European and global level”. This Forum answers to the European...

  13. Fractures of the humerus during arm wrestling

    Directory of Open Access Journals (Sweden)

    Bumbaširević Marko Ž.

    2014-01-01

    Full Text Available Background/Aim. Humeral shaft fractures may occur as a result of arm wrestling. The aim of this study was to present our treatment of humerus fracture sustained during arm wrestling. Methods. A total of six patients, aged 22 to 48, were treated at our department form January 2008 to January 2010 with open reduction and internal fixation and with hanging arm casts. A review of all the relevant literature on the subject was also presented. Results. In all the cases, the fractures healed and function returned to normal. No patient had any neural or vascular compromise. Conclusion. Closed and operative treatments were equally successful in all reported cases. [Projekat Ministarstva nauke Republike Srbije, br. 175-095

  14. ARM Climate Research Facility Annual Report 2005

    Energy Technology Data Exchange (ETDEWEB)

    J. Voyles

    2005-12-31

    Through the ARM Program, the DOE funded the development of several highly instrumented ground stations for studying cloud formation processes and their influence on radiative transfer, and for measuring other parameters that determine the radiative properties of the atmosphere. This scientific infrastructure, and resultant data archive, is a valuable national and international asset for advancing scientific knowledge of Earth systems. In fiscal year (FY) 2003, the DOE designated ARM sites as a national scientific user facility: the ARM Climate Research (ACRF). The ACRF has enormous potential to contribute to a wide range interdisciplinary science in areas such as meteorology, atmospheric aerosols, hydrology, biogeochemical cycling, and satellite validation, to name only a few.

  15. Arms Trafficking and Colombia

    National Research Council Canada - National Science Library

    Cragin, Kim; Hoffman, Bruce

    2003-01-01

    ... to traditional definitions of a security threat. For this analysis, the term "small arms" refers to man-portable personal and military weapons, ranging from handguns to assault rifles to surface-to-air missiles (SAMs...

  16. EEG Mind Controlled Smart Prosthetic Arm – A Comprehensive Study

    Directory of Open Access Journals (Sweden)

    Taha Beyrouthy

    2017-06-01

    Full Text Available Recently, the field of prosthetics has seen many accomplishments especially with the integration of technological advancements. In this paper, different arm types (robotic, surgical, bionic, prosthetic and static are analyzed in terms of resistance, usage, flexibility, cost and potential. Most of these techniques have some problems; they are extremely expensive, hard to install and maintain and may require surgery. Therefore, our work introduces the initial design of an EEG mind controlled smart prosthetic arm. The arm is controlled by the brain commands, obtained from an electroencephalography (EEG headset, and equipped with a network of smart sensors and actuators that give the patient intelligent feedback about the surrounding environment and the object in contact. This network provides the arm with normal hand functionality, smart reflexes and smooth movements. Various types of sensors are used including temperature, pressure, ultrasonic proximity sensors, accelerometers, potentiometers, strain gauges and gyroscopes. The arm is completely 3D printed built from various lightweight and high strength materials that can handle high impacts and fragile elements as well. Our project requires the use of nine servomotors installed at different places in the arm. Therefore, the static and dynamic modes of servomotors are analyzed. The total cost of the project is estimated to be relatively cheap compared to other previously built arms. Many scenarios are analyzed corresponding to the actions that the prosthetic arm can perform, and an algorithm is created to match these scenarios. Experimental results show that the proposed EEG Mind-controlled Arm is a promising alternative for current solutions that require invasive and expensive surgical procedures.

  17. A Unified Approach for Reporting ARM Measurement Uncertainties Technical Report

    Energy Technology Data Exchange (ETDEWEB)

    Campos, E [Argonne National Laboratory; Sisterson, DL [Argonne National Laboratory

    2015-10-01

    The Atmospheric Radiation Measurement (ARM) Climate Research Facility is observationally based, and quantifying the uncertainty of its measurements is critically important. With over 300 widely differing instruments providing over 2,500 datastreams, concise expression of measurement uncertainty is quite challenging. The ARM Facility currently provides data and supporting metadata (information about the data or data quality) to its users through a number of sources. Because the continued success of the ARM Facility depends on the known quality of its measurements, the Facility relies on instrument mentors and the ARM Data Quality Office (DQO) to ensure, assess, and report measurement quality. Therefore, an easily-accessible, well-articulated estimate of ARM measurement uncertainty is needed.

  18. Participation in Armed Forces, National, and International Sports Activities

    Science.gov (United States)

    1987-03-09

    American Games , Olympic Games , and other authorized national and international sports competitions (to include qualifying and preparatory events) as long...concerning the participation of Armed Forces personnel in Armed Forces, national, and international sports competitions ; establishes a Senior Military Sports ...program is to ensure that the U.S. Armed Forces are appropriately represented in national and international sports competitions . 3. The purpose of this

  19. The effect of arm sling on balance in patients with hemiplegia.

    Science.gov (United States)

    Acar, Merve; Karatas, Gulcin Kaymak

    2010-10-01

    The aim of this study was to investigate the effect of an arm sling on balance in patients with, hemiplegia following a stroke. Twenty-six patients with hemiplegia (11 men, 15 women) who had, shoulder subluxation were enrolled in the study. Balance was evaluated by the Berg Balance Scale, the, Functional Reach test, and a static balance index which was measured by the Kinesthetic Ability, Trainer 3000. Balance tests were performed twice, with arm sling and without arm sling use. Results of, this study show that the Berg Balance Scores and static balance index ameliorated with arm sling use (p=0.005 and p=0.004, respectively). Likewise, the Functional Reach test was better when performed with an arm sling (p=0.039). In conclusion, arm slings have a beneficial effect on balance in patients, with hemiplegia. An arm sling may be applied for its possible beneficial effect on balance especially in, the early phases of stroke rehabilitation while the upper extremity is still flaccid and arm swing is, reduced. Copyright © 2010 Elsevier B.V. All rights reserved.

  20. Spiral arms, comets and terrestrial catastrophism

    International Nuclear Information System (INIS)

    Clube, S.V.M.; Napier, W.M.

    1982-01-01

    A review is presented of an hypothesis of terrestrial catastrophism in which comets grow in molecular clouds and are captured by the Sun as it passes through the spiral arms of the Galaxy. Assuming that comets are a major supplier of the Earth-crossing (Appollo) asteroid population, the latter fluctuates correspondingly and leads to episodes of terrestrial bombardment. Changes in the rotational momentum of core and mantle, generated by impacts, lead to episodes of magnetic field reversal and tectonic activity, while surface phenomena lead to ice-ages and mass extinctions. An episodic geophysical history with an interstellar connection is thus implied. If comets in spiral arms are necessary intermediaries in the process of star formation, the theory also has implications relating to early solar system history and galactic chemistry. These aspects are briefly discussed with special reference to the nature of spiral arms. (author)

  1. Stress analysis for robot arm version 2

    International Nuclear Information System (INIS)

    Anwar Abdul Rahman; Fikri, A.; Salleh, M. S.; Mohd Arif Hamzah; Azraf Azman; Rosli Darmawan; Mohd Rizal Mamat

    2010-01-01

    The design of a robot needs to be analyzed to ensure the specification and requirement by the user is full filled. Therefore, stress analysis has been performed on the robot arm version 2 after its complete fabrication. This paper discusses the result of the analysis and proposed measures to improve the future design of robot arm. (author)

  2. C-arm CT for chemo-embolization of liver tumors

    International Nuclear Information System (INIS)

    Huppert, P.E.; Firlbeck, G.; Meissner, O.A.; Wietholtz, H.

    2009-01-01

    Local efficacy of transarterial chemo-embolization (TACE) is enhanced if selective treatment is performed. Selectivity of TACE mainly depends on vascular anatomy but also on the identification and catheterization of tumor feeding arteries. Correlation of vascular territories and target tumor volume in angiographic projection images is more difficult if tumors are not hypervascularized and contrast of liver parenchyma is inhomogeneous. C-arm CT offers the option of selective perfusion imaging via tumor-feeding arteries. This allows the comparison of perfusion images and baseline cross-sectional imaging to evaluate if tumors are covered completely by local treatment and to change the catheter position if necessary. Furthermore the uptake of embolization material, such as lipiodol can be checked by C-arm CT. In a prospective study of 75 TACE of liver tumors and liver metastases we evaluated the appropriateness of 85 catheter positions ready for delivery by perfusion C-arm CT and compared the diagnostic confidence of angiography and perfusion C-arm CT in terms of judgment of correct catheter position for the planned treatment. Diagnostic confidence was improved by perfusion C-arm CT in 55% of cases and in 11 cases (13%) catheter positions were inappropriate and had to be corrected. The reasons for catheter repositioning were incomplete coverage of the target tumor by perfusion volume (mismatch) in 6 cases, inappropriate perfusion of adjacent liver parenchyma in 2 cases and non-selective tumor perfusion via collateral arteries in 3 cases. C-arm CT allowed sufficient visualization of uptake of lipiodol in all cases evaluated. The diagnostic benefit of C-arm CT increases if tumors are treated more selectively, are not strongly hypervascular, are located centrally and if the enhancement of liver parenchyma is inhomogeneous. C-arm CT causes additional working time and contrast load, which is relatively low compared to angiography. Radiation exposure of 151 μGy per C-arm

  3. Head, Neck, and Oral Cancer

    Medline Plus

    Full Text Available ... Head and Neck Pathology Oral, Head and Neck Pathology Close to 49,750 Americans will be diagnosed ... Head and Neck Pathology Oral, Head and Neck Pathology Close to 49,750 Americans will be diagnosed ...

  4. Evaluation of the dose distribution of dynamic conical conformal therapy using a C-arm mounted accelerator

    International Nuclear Information System (INIS)

    Nakagawa, Keiichi; Aoki, Yukimasa; Ohtomo, Kuni

    2001-01-01

    Conformal radiation therapy, which is widely utilized in Japan as a standard, highly precise technique has limited advantage in dose confinement because of its coplanar beam entry. An improved form of conformal therapy is delivered by a linac mounted on a C-arm rotatable gantry. The linac head was designed to move along the C-arm with a maximum angle of 60 degrees. Simultaneous rotation of the gantry creates a Dynamic Conical irradiation technique. Dynamic Conical Conformal Therapy (Dyconic Therapy) was developed by combining the technique with continuous MLC motion based on beam's eye views of the target volume. Dose distributions were measured in a phantom using film densitometry and compared with conventional conformal radiation therapy. The measurements showed that the dose distribution conformed to the target shape identified by CT. In addition, the dose distribution for a cancer patient was evaluated through the use of DVHs generated by a treatment planning system. These measurements showed that the dose distribution along the patient's long axis conformed to the shape of the target volume. DVH analysis, however, did not indicate superiority of the present technique over the conventional technique. Angulation of the C-arm gantry allowed the primary beam to strike a larger area of the therapy room. This necessitated adding shielding to the walls and ceiling of the treatment room. It was confirmed that the leakage radiation was reduced to a negligible level by adding an iron plate 20 cm thick to several places on the side walls, by adding an iron plate 9 cm thick to several places on the ceiling, and by increasing the thickness of the concrete ceiling from 70 to 140 cm. The possible usefulness of Dyconic Therapy was confirmed. (author)

  5. Design and analysis on robotic arm for serving hazard container

    Science.gov (United States)

    Razali, Zol Bahri; Kader, Mohamed Mydin M. Abdul; Yi, Khoo Zern; Daud, Mohd Hisam

    2017-09-01

    This paper presents about design, analyses development and fabrication of robotic arm for sorting multi-material. The major problem that urges the initiation of the project is the fact that manufacturing industry is growing at relatively faster rate. Most of the company produce high load robotic arm. Less company creates light weight, and affordable robotic arm. As the result, light weight and affordable robot is developing to cover this issue. Plastic material was used to construct the body of the robotic arm, and an optical sensor was implemented to provide basic recognition of object to be carried. The robotic arm used five servomotors for overall operation; four for its joints, and one for the gripping mechanism. The gripper was designed and fabricated using Perspex due to the light weight and high strength of the material. The operation of the robotic arm was governed by Basic Stamp programming sequence and the device was expected to differentiate material and other objects based on reflective theory, and perform subsequent operations afterwards. The SolidWorks was used to model the detail design of the robotic arm, and to simulate the motion of the device.

  6. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special x-ray ... What is CT Scanning of the Head? Computed tomography, more commonly known as a CT or CAT ...

  7. AN OUTER ARM IN THE SECOND GALACTIC QUADRANT: STRUCTURE

    Energy Technology Data Exchange (ETDEWEB)

    Du, Xinyu; Xu, Ye; Yang, Ji; Sun, Yan; Li, Facheng; Zhang, Shaobo; Zhou, Xin, E-mail: xydu@pmo.ac.cn, E-mail: xuye@pmo.ac.cn [Purple Mountain Observatory, Chinese Academy of Science, Nanjing 210008 (China)

    2016-05-01

    The lack of arm tracers, especially remote tracers, is one of the most difficult problems preventing us from studying the structure of the Milky Way. Fortunately, with its high-sensitivity CO survey, the Milky Way Imaging Scroll Painting (MWISP) project offers such an opportunity. Since completing about one-third of its mission, an area of l = [100, 150]°, b = [−3, 5]° has nearly been covered. The Outer arm of the Milky Way first clearly revealed its shape in the second galactic quadrant in the form of molecular gas—this is the first time that the Outer arm has been reported in such a large-scale mapping of molecular gas. Using the 115 GHz {sup 12}CO(1–0) data of MWISP at the LSR velocity ≃[−100, −60] km s{sup −1} and in the area mentioned above, we have detected 481 molecular clouds in total, and among them 332 (about 69%) are newly detected and 457 probably belong to the Outer arm. The total mass of the detected Outer arm clouds is ∼3.1 × 10{sup 6} M {sub ⊙}. Assuming that the spiral arm is a logarithmic spiral, the pitch angle is fitted as ∼13.°1. Besides combining both the CO data from MWISP and the 21 cm H i data from the Canadian Galactic Plane Survey (CGPS), the gas distribution, warp, and thickness of the Outer arm are also studied.

  8. Armed guards on vessels : insurance and liability

    Directory of Open Access Journals (Sweden)

    Mišo Mudrić

    2011-12-01

    Full Text Available The Paper examines the insurance and liability issues resulting from the use of armed guards on board vessels. The study begins with an overview of the available data on key economic fi gures representing the projected overall annual costs of modern piracy. The focus is then shifted to the issue of public versus private security, where possible dangers of private-based security options are discussed in general. After explaining why the Somalia region deserves a closer attention when compared to other pirate-infested waters, a brief summary of the international effort to combat piracy threat is presented, followed by a structured overview of the use of private maritime security options in the maritime sector in general. One security option is the use of armed guards on board vessels. This option is explored both from the political (the acceptance by stakeholders and legal standpoint (legal issues arising from the use of armed guards. An important remedy for the shipping companies/ operators threatened by the piracy hazard is the existence of affordable and effective (specialized marine insurance. A study of available piracy insurance policies is presented, followed by an analysis of case law and other legal issues arising from piracy attacks, which could prove important when considering the legal implications of armed guards employment. Finally, a simplifi ed economic analysis of available security options is presented, followed by the final assessment of benefi ts derived from the use of armed guards.

  9. Analyst Tools and Quality Control Software for the ARM Data System

    Energy Technology Data Exchange (ETDEWEB)

    Moore, S.T.

    2004-12-14

    ATK Mission Research develops analyst tools and automated quality control software in order to assist the Atmospheric Radiation Measurement (ARM) Data Quality Office with their data inspection tasks. We have developed a web-based data analysis and visualization tool, called NCVweb, that allows for easy viewing of ARM NetCDF files. NCVweb, along with our library of sharable Interactive Data Language procedures and functions, allows even novice ARM researchers to be productive with ARM data with only minimal effort. We also contribute to the ARM Data Quality Office by analyzing ARM data streams, developing new quality control metrics, new diagnostic plots, and integrating this information into DQ HandS - the Data Quality Health and Status web-based explorer. We have developed several ways to detect outliers in ARM data streams and have written software to run in an automated fashion to flag these outliers.

  10. Prevalence of inter-arm blood pressure difference among clinical out-patients.

    Science.gov (United States)

    Sharma, Balkishan; Ramawat, Pramila

    2016-04-01

    An increased inter-arm blood pressure difference is an easily determined physical finding, may use as an indicator of cardio vascular event and other sever diseases. Authors evaluated 477 patients to determine the prevalence and significance of inter-arm blood pressure difference. 477 routine outdoor patients selected to observe the inter-arm blood pressure difference. Age, height, weight, body mass index, history of disease and blood pressure recorded. The prevalence of ≥10 mmHg systolic inter-arm blood pressure difference was 5.0% was more as compared to 3.8% had diastolic inter-arm blood pressure difference. The prevalence of systolic and diastolic inter-arm difference between 6 to 10 mmHg was 31.4% and 27.9% respectively. Mean systolic inter-arm blood pressure difference was significantly higher among those patients had a multisystem disorder (10.57±0.98 mmHg) and followed by patients with cardiovascular disease (10.22±0.67 mmHg) as compared to healthy patients (2.71±0.96 mmHg). Various diseases highly influenced the increase in blood pressure irrespective of systolic or diastolic was confirmed strongly significant (pdifferent inter arm blood pressure difference levels. This study supports the view of inter-arm blood pressure difference as an alarming stage of increased disease risk that incorporated to investigate potential problems at an early diagnostic stage. A significant mean difference between left and right arm blood pressure recorded for many diseases.

  11. Effect of Facial Cosmetic Acupuncture on Facial Elasticity: An Open-Label, Single-Arm Pilot Study

    Directory of Open Access Journals (Sweden)

    Younghee Yun

    2013-01-01

    Full Text Available Background. The use of acupuncture for cosmetic purposes has gained popularity worldwide. Facial cosmetic acupuncture (FCA is applied to the head, face, and neck. However, little evidence supports the efficacy and safety of FCA. We hypothesized that FCA affects facial elasticity by restoring resting mimetic muscle tone through the insertion of needles into the muscles of the head, face, and neck. Methods. This open-label, single-arm pilot study was implemented at Kyung Hee University Hospital at Gangdong from August through September 2011. Participants were women aged 40 to 59 years with a Glogau photoaging scale III. Participants received five treatment sessions over three weeks. Participants were measured before and after FCA. The primary outcome was the Moire topography criteria. The secondary outcome was a patient-oriented self-assessment scale of facial elasticity. Results. Among 50 women screened, 28 were eligible and 27 completed the five FCA treatment sessions. A significant improvement after FCA treatment was evident according to mean change in Moire topography criteria (from 1.70 ± 0.724 to 2.26 ± 1.059, P<0.0001. The most common adverse event was mild bruising at the needle site. Conclusions. In this pilot study, FCA showed promising results as a therapy for facial elasticity. However, further large-scale trials with a controlled design and objective measurements are needed.

  12. Magnetic Resonance Imaging (MRI) -- Head

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - Head Magnetic resonance imaging (MRI) of the head uses a powerful ... the Head? What is MRI of the Head? Magnetic resonance imaging (MRI) is a noninvasive medical test that ...

  13. Optimization on robot arm machining by using genetic algorithms

    Science.gov (United States)

    Liu, Tung-Kuan; Chen, Chiu-Hung; Tsai, Shang-En

    2007-12-01

    In this study, an optimization problem on the robot arm machining is formulated and solved by using genetic algorithms (GAs). The proposed approach adopts direct kinematics model and utilizes GA's global search ability to find the optimum solution. The direct kinematics equations of the robot arm are formulated and can be used to compute the end-effector coordinates. Based on these, the objective of optimum machining along a set of points can be evolutionarily evaluated with the distance between machining points and end-effector positions. Besides, a 3D CAD application, CATIA, is used to build up the 3D models of the robot arm, work-pieces and their components. A simulated experiment in CATIA is used to verify the computation results first and a practical control on the robot arm through the RS232 port is also performed. From the results, this approach is proved to be robust and can be suitable for most machining needs when robot arms are adopted as the machining tools.

  14. A Scintigraphic Method for Quantitation of Lymphatic Function in Arm Lymphedema

    DEFF Research Database (Denmark)

    Hvidsten, Svend; Toyserkani, Navid M; Sørensen, Jens A

    2018-01-01

    ) measure of lymph fluid passing through the arm. METHODS AND RESULTS: Eleven patients, aged 34-68 years, with unilateral arm lymphedema following breast cancer treatment underwent simultaneous bilateral lymphoscintigraphy using intradermal injection of 99mTc-labeled human serum albumin (HSA). Imaging...... was performed at 30-45 minute intervals for 5 hours. Time activity curves from each injection site and each arm region were recorded. The input into the arm region was obtained as the (minus) time derivative of the injection site activity curve. In the proposed model the arm activity curve was considered...

  15. Analysis of hypothetical loss-of-control-arm accidents in HIFAR

    International Nuclear Information System (INIS)

    Connolly, J.W.; Clark, N.

    1986-11-01

    The reactor power transient produced in the HIFAR materials testing reactor upon severance of a central coarse control arm connecting rod and the subsequent pivoting of the arm out of the core has been calculated for a range of reactor conditions likely to be encountered in normal operation. It is concluded that as long as the remaining arms of the control arm bank can be relied on to suppress the post power peak oscillations in power, the reactor will withstand the consequences of such an accident

  16. Reactor head shielding apparatus

    International Nuclear Information System (INIS)

    Schukei, G.E.; Roebelen, G.J.

    1992-01-01

    This patent describes a nuclear reactor head shielding apparatus for mounting on spaced reactor head lifting members radially inwardly of the head bolts. It comprises a frame of sections for mounting on the lifting members and extending around the top central area of the head, mounting means for so mounting the frame sections, including downwardly projecting members on the frame sections and complementary upwardly open recessed members for fastening to the lifting members for receiving the downwardly projecting members when the frame sections are lowered thereto with lead shielding supported thereby on means for hanging lead shielding on the frame to minimize radiation exposure or personnel working with the head bolts or in the vicinity thereof

  17. Head, Neck, and Oral Cancer

    Science.gov (United States)

    ... find out more. Oral, Head and Neck Pathology Oral, Head and Neck Pathology Close to 49,750 Americans will be diagnosed ... find out more. Oral, Head and Neck Pathology Oral, Head and Neck Pathology Close to 49,750 Americans will be diagnosed ...

  18. Overview of Actuated Arm Support Systems and Their Applications

    Directory of Open Access Journals (Sweden)

    E.A. Lomonova

    2013-10-01

    Full Text Available Arm support systems provide support throughout daily tasks, training or in an industrial environment. During the last decades a large diversity of actuated arm support systems have been developed. To analyze the actuation principles in these systems, an overview of actuated arm support systems is provided. This overview visualizes the current trends on research and development of these support systems and distinguishes three categories. These categories depend mainly on the functional status of the user environment, which defines the specifications. Therefore, the actuated arm support systems are classified according to their user environment, namely: ambulatory, rehabilitation and industrial. Furthermore, three main actuation principles and three mechanical construction principles have been identified.

  19. Mid-upper-arm-circumference and mid-upper-arm circumference z-score

    DEFF Research Database (Denmark)

    Rasmussen, J; Andersen, A; Fisker, A B

    2012-01-01

    Mid-upper-arm circumference (MUAC) is a simple method of assessing nutritional status in children above 6 months of age. In 2007 World Health Organization (WHO) introduced a MUAC z-score for children above 3 months of age. We evaluated whether MUAC or MUAC z-score had the best ability to identify...

  20. Heading Frequency Is More Strongly Related to Cognitive Performance Than Unintentional Head Impacts in Amateur Soccer Players.

    Science.gov (United States)

    Stewart, Walter F; Kim, Namhee; Ifrah, Chloe; Sliwinski, Martin; Zimmerman, Molly E; Kim, Mimi; Lipton, Richard B; Lipton, Michael L

    2018-01-01

    Compared to heading, unintentional head impacts (e.g., elbow to head, head to head, head to goalpost) in soccer are more strongly related to risk of moderate to very severe Central Nervous System (CNS) symptoms. But, most head impacts associated with CNS symptoms that occur in soccer are mild and are more strongly related to heading. We tested for a differential relation of heading and unintentional head impacts with neuropsychological (NP) test performance. Active adult amateur soccer players were recruited in New York City and the surrounding areas for this repeated measures longitudinal study of individuals who were enrolled if they had 5+ years of soccer play and were active playing soccer 6+ months/year. All participants completed a baseline validated questionnaire ("HeadCount-2w"), reporting 2-week recall of soccer activity, heading and unintentional head impacts. In addition, participants also completed NP tests of verbal learning, verbal memory, psychomotor speed, attention, and working memory. Most participants also completed one or more identical follow-up protocols (i.e., HeadCount-2w and NP tests) at 3- to 6-month intervals over a 2-year period. Repeated measures General Estimating Equations (GEE) linear models were used to determine if variation in NP tests at each visit was related to variation in either heading or unintentional head impacts in the 2-week period before testing. 308 players (78% male) completed 741 HeadCount-2w. Mean (median) heading/2-weeks was 50 (17) for men and 26 (7) for women. Heading was significantly associated with poorer performance on psychomotor speed ( p  impacts were not significantly associated with any NP test. Results did not differ after excluding 22 HeadCount-2w with reported concussive or borderline concussive symptoms. Poorer NP test performance was consistently related to frequent heading during soccer practice and competition in the 2 weeks before testing. In contrast, unintentional head impacts incurred

  1. Registration of 2D C-Arm and 3D CT Images for a C-Arm Image-Assisted Navigation System for Spinal Surgery

    Directory of Open Access Journals (Sweden)

    Chih-Ju Chang

    2015-01-01

    Full Text Available C-Arm image-assisted surgical navigation system has been broadly applied to spinal surgery. However, accurate path planning on the C-Arm AP-view image is difficult. This research studies 2D-3D image registration methods to obtain the optimum transformation matrix between C-Arm and CT image frames. Through the transformation matrix, the surgical path planned on preoperative CT images can be transformed and displayed on the C-Arm images for surgical guidance. The positions of surgical instruments will also be displayed on both CT and C-Arm in the real time. Five similarity measure methods of 2D-3D image registration including Normalized Cross-Correlation, Gradient Correlation, Pattern Intensity, Gradient Difference Correlation, and Mutual Information combined with three optimization methods including Powell’s method, Downhill simplex algorithm, and genetic algorithm are applied to evaluate their performance in converge range, efficiency, and accuracy. Experimental results show that the combination of Normalized Cross-Correlation measure method with Downhill simplex algorithm obtains maximum correlation and similarity in C-Arm and Digital Reconstructed Radiograph (DRR images. Spine saw bones are used in the experiment to evaluate 2D-3D image registration accuracy. The average error in displacement is 0.22 mm. The success rate is approximately 90% and average registration time takes 16 seconds.

  2. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - Head Magnetic resonance imaging (MRI) of the head uses a powerful ... the Head? What is MRI of the Head? Magnetic resonance imaging (MRI) is a noninvasive medical test that ...

  3. Head, Neck, and Oral Cancer

    Medline Plus

    Full Text Available ... find out more. Oral, Head and Neck Pathology Oral, Head and Neck Pathology Close to 49,750 Americans will be diagnosed ... find out more. Oral, Head and Neck Pathology Oral, Head and Neck Pathology Close to 49,750 Americans will be diagnosed ...

  4. Head-positioning scintillation camera and head holder therefor

    International Nuclear Information System (INIS)

    Kay, T.D.

    1976-01-01

    A holder for immobilizing the head of a patient undergoing a vertex brain scan by a Gamma Scintillation Camera is described. The holder has a uniquely designed shape capable of comfortably supporting the head. In addition, this holder can be both adjustably and removably utilized in combination with the scintillation camera so as to enable the brain scan operation to take place while the patient is in the seated position

  5. Systems Approach to Arms Control Verification

    Energy Technology Data Exchange (ETDEWEB)

    Allen, K; Neimeyer, I; Listner, C; Stein, G; Chen, C; Dreicer, M

    2015-05-15

    Using the decades of experience of developing concepts and technologies for verifying bilateral and multilateral arms control agreements, a broad conceptual systems approach is being developed that takes into account varying levels of information and risk. The IAEA has already demonstrated the applicability of a systems approach by implementing safeguards at the State level, with acquisition path analysis as the key element. In order to test whether such an approach could also be implemented for arms control verification, an exercise was conducted in November 2014 at the JRC ITU Ispra. Based on the scenario of a hypothetical treaty between two model nuclear weapons states aimed at capping their nuclear arsenals at existing levels, the goal of this exercise was to explore how to use acquisition path analysis in an arms control context. Our contribution will present the scenario, objectives and results of this exercise, and attempt to define future workshops aimed at further developing verification measures that will deter or detect treaty violations.

  6. Smooth-arm spiral galaxies: their properties and significance to cluster-galaxy evolution

    International Nuclear Information System (INIS)

    Wilkerson, M.S.

    1979-01-01

    In this dissertation a number of galaxies with optical appearances between those of normal, actively-star-forming spirals and SO galaxies have been examined. These so-called smooth-arm spiral galaxies exhibit spiral arms without any of the spiral tracers - H II regions, O-B star associations, dust - indicative of current star formation. Tests were made to find if, perhaps, these smooth-arm spirals could have, at one time, been normal, actively-star-forming spirals whose gas had been somehow removed; and that are currently transforming into SO galaxies. This scenario proceeds as (1) removal of gas, (2) gradual dying of disk density wave, (3) emergence of SO galaxy. If the dominant method of gas removal is ram-pressure stripping by a hot, intracluster medium, then smooth-arm spirals should occur primarily in x-ray clusters. Some major findings of this dissertation are as follows: (1) Smooth-arm spirals are redder than normal spirals of the same morphological type. Most smooth-arm spirals cannot be distinguished by color from SO galaxies. (2) A weak trend exists for smooth-arm spirals with stronger arms to be bluer than those with weaker arms; thus implying that the interval since gas removal has been shorter for the galaxies with stronger arms. (3) Smooth-arm spirals are deficient in neutral hydrogen - sometimes by an order of magnitude or, possibly, more

  7. Dynamic model of the octopus arm. II. Control of reaching movements.

    Science.gov (United States)

    Yekutieli, Yoram; Sagiv-Zohar, Roni; Hochner, Binyamin; Flash, Tamar

    2005-08-01

    The dynamic model of the octopus arm described in the first paper of this 2-part series was used here to investigate the neural strategies used for controlling the reaching movements of the octopus arm. These are stereotypical extension movements used to reach toward an object. In the dynamic model, sending a simple propagating neural activation signal to contract all muscles along the arm produced an arm extension with kinematic properties similar to those of natural movements. Control of only 2 parameters fully specified the extension movement: the amplitude of the activation signal (leading to the generation of muscle force) and the activation traveling time (the time the activation wave takes to travel along the arm). We found that the same kinematics could be achieved by applying activation signals with different activation amplitudes all exceeding some minimal level. This suggests that the octopus arm could use minimal amplitudes of activation to generate the minimal muscle forces required for the production of the desired kinematics. Larger-amplitude signals would generate larger forces that increase the arm's stability against perturbations without changing the kinematic characteristics. The robustness of this phenomenon was demonstrated by examining activation signals with either a constant or a bell-shaped velocity profile. Our modeling suggests that the octopus arm biomechanics may allow independent control of kinematics and resistance to perturbation during arm extension movements.

  8. Heading Frequency Is More Strongly Related to Cognitive Performance Than Unintentional Head Impacts in Amateur Soccer Players

    Directory of Open Access Journals (Sweden)

    Walter F. Stewart

    2018-04-01

    Full Text Available ObjectiveCompared to heading, unintentional head impacts (e.g., elbow to head, head to head, head to goalpost in soccer are more strongly related to risk of moderate to very severe Central Nervous System (CNS symptoms. But, most head impacts associated with CNS symptoms that occur in soccer are mild and are more strongly related to heading. We tested for a differential relation of heading and unintentional head impacts with neuropsychological (NP test performance.MethodActive adult amateur soccer players were recruited in New York City and the surrounding areas for this repeated measures longitudinal study of individuals who were enrolled if they had 5+ years of soccer play and were active playing soccer 6+ months/year. All participants completed a baseline validated questionnaire (“HeadCount-2w”, reporting 2-week recall of soccer activity, heading and unintentional head impacts. In addition, participants also completed NP tests of verbal learning, verbal memory, psychomotor speed, attention, and working memory. Most participants also completed one or more identical follow-up protocols (i.e., HeadCount-2w and NP tests at 3- to 6-month intervals over a 2-year period. Repeated measures General Estimating Equations (GEE linear models were used to determine if variation in NP tests at each visit was related to variation in either heading or unintentional head impacts in the 2-week period before testing.Results308 players (78% male completed 741 HeadCount-2w. Mean (median heading/2-weeks was 50 (17 for men and 26 (7 for women. Heading was significantly associated with poorer performance on psychomotor speed (p < 0.001 and attention (p = 0.02 tasks and was borderline significant with poorer performance on the working memory (p = 0.06 task. Unintentional head impacts were not significantly associated with any NP test. Results did not differ after excluding 22 HeadCount-2w with reported concussive or borderline concussive symptoms

  9. Metabolic and cardiorespiratory response in swimmers during head-out immersion: a prospective study.

    Science.gov (United States)

    Mesfar, Mohamed A; Zendah, Ines; Gharsalli, Houda; Ben Hassen, Chokri; Ghedira, Habib

    2012-11-01

    Sport represents a stress for the body. Many metabolic and cardiorespiratory changes are known during physical activity.However, litte is known in swimmers particularly during head-out immersion. To determine the metabolic and cardiorespiratory response in swimmers during head-out immersion. The energetic, cardiovascular function and ventilatory requirements of a 10 min steady state arm exercise performed by 13 healthy subjects in air and during immersion up to the hip in 26°C water were compared. The same ergometric work load was achieved with an average maximum oxygen uptake of 3.9 ± 2.63 l/min in air versus 3.55 ± 2.48 l/min in water (p=0.953). During exercise, the average values of minute ventilation, ventilation equivalent for oxygen, ventilation equivalent for CO2, peak expiratory flow, respiratory exchange ratio and heart rate were not different in water and in air. However, first ventilatory threshold was significantly higher in water than in air. The mean value of the first ventilatory threshold was 0.89 ± 0.23 l/min in air, and 1.08 ± 0.23 l/min in water immersion; (p=0.016). These results suggest that training swimmers favoring immersion (weight belts) may improve their aerobic capacity.

  10. 'Pharyngocise': Randomized Controlled Trial of Preventative Exercises to Maintain Muscle Structure and Swallowing Function During Head-and-Neck Chemoradiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Carnaby-Mann, Giselle, E-mail: gmann@phhp.ufl.edu [Department of Behavioral Science and Community Health, University of Florida, Gainesville, FL (United States); Crary, Michael A. [Department of Speech Language and Hearing Sciences, University of Florida, Gainesville, FL (United States); Schmalfuss, Ilona [Department of Radiology, North Florida/South Georgia Veterans Health System, Gainesville, FL (Georgia); Amdur, Robert [Department of Radiation Oncology, University of Florida, Gainesville, FL (United States)

    2012-05-01

    Purpose: Dysphagia after chemoradiotherapy is common. The present randomized clinical trial studied the effectiveness of preventative behavioral intervention for dysphagia compared with the 'usual care.' Methods and Materials: A total of 58 head-and-neck cancer patients treated with chemoradiotherapy were randomly assigned to usual care, sham swallowing intervention, or active swallowing exercises (pharyngocise). The intervention arms were treated daily during chemoradiotherapy. The primary outcome measure was muscle size and composition (determined by T{sub 2}-weighted magnetic resonance imaging). The secondary outcomes included functional swallowing ability, dietary intake, chemosensory function, salivation, nutritional status, and the occurrence of dysphagia-related complications. Results: The swallowing musculature (genioglossus, hyoglossuss, and mylohyoid) demonstrated less structural deterioration in the active treatment arm. The functional swallowing, mouth opening, chemosensory acuity, and salivation rate deteriorated less in the pharyngocise group. Conclusion: Patients completing a program of swallowing exercises during cancer treatment demonstrated superior muscle maintenance and functional swallowing ability.

  11. JPRS Report, Soviet Union, Political Affairs, Volkogonov’s Political Portrait of Stalin

    Science.gov (United States)

    1990-11-09

    paneled with treated oak. Stalin continued to pace up and down along the long table draped in green cloth, with a large map showing the operational...tank and two mechanized corps, 20 infantry and 46 Armour brigades were moved in Stalingrad’s direction at the Stavka’s order between July 1 and...body, a squat torso and rather long arms and legs. The military tunic showed a pouch draped in the Marshall’s uniform. He had thin hair and a pock

  12. Experimental investigation of biodynamic human body models subjected to whole-body vibration during a vehicle ride.

    Science.gov (United States)

    Taskin, Yener; Hacioglu, Yuksel; Ortes, Faruk; Karabulut, Derya; Arslan, Yunus Ziya

    2018-02-06

    In this study, responses of biodynamic human body models to whole-body vibration during a vehicle ride were investigated. Accelerations were acquired from three different body parts, such as the head, upper torso and lower torso, of 10 seated passengers during a car ride while two different road conditions were considered. The same multipurpose vehicle was used during all experiments. Additionally, by two widely used biodynamic models in the literature, a set of simulations were run to obtain theoretical accelerations of the models and were compared with those obtained experimentally. To sustain a quantified comparison between experimental and theoretical approaches, the root mean square acceleration and acceleration spectral density were calculated. Time and frequency responses of the models demonstrated that neither of the models showed the best prediction performance of the human body behaviour in all cases, indicating that further models are required for better prediction of the human body responses.

  13. A prognostic scoring system for arm exercise stress testing.

    Science.gov (United States)

    Xie, Yan; Xian, Hong; Chandiramani, Pooja; Bainter, Emily; Wan, Leping; Martin, Wade H

    2016-01-01

    Arm exercise stress testing may be an equivalent or better predictor of mortality outcome than pharmacological stress imaging for the ≥50% for patients unable to perform leg exercise. Thus, our objective was to develop an arm exercise ECG stress test scoring system, analogous to the Duke Treadmill Score, for predicting outcome in these individuals. In this retrospective observational cohort study, arm exercise ECG stress tests were performed in 443 consecutive veterans aged 64.1 (11.1) years. (mean (SD)) between 1997 and 2002. From multivariate Cox models, arm exercise scores were developed for prediction of 5-year and 12-year all-cause and cardiovascular mortality and 5-year cardiovascular mortality or myocardial infarction (MI). Arm exercise capacity in resting metabolic equivalents (METs), 1 min heart rate recovery (HRR) and ST segment depression ≥1 mm were the stress test variables independently associated with all-cause and cardiovascular mortality by step-wise Cox analysis (all pstatistic of 0.81 before and 0.88 after adjustment for significant demographic and clinical covariates. Arm exercise scores for the other outcome end points yielded C-statistic values of 0.77-0.79 before and 0.82-0.86 after adjustment for significant covariates versus 0.64-0.72 for best fit pharmacological myocardial perfusion imaging models in a cohort of 1730 veterans who were evaluated over the same time period. Arm exercise scores, analogous to the Duke Treadmill Score, have good power for prediction of mortality or MI in patients who cannot perform leg exercise.

  14. The purposes, achievements, and priorities of arms control

    International Nuclear Information System (INIS)

    Brown, P.S.

    1987-09-01

    Arms control purposes include strengthening the framework of deterrence and reducing the threat of the use of nuclear weapons, reducing the dangers of attack and accidental nuclear war, and allowing more resources for the civilian economy. The paper briefly describes achievements in arms control since World War II. These include the Limited Test Ban Treaty (LTBT), Nonproliferation Treaty (NPT), Anti-Ballistic Missile Treaty (ABMT)-SALT I, SALT II, Threshold Test Ban Treaty (TTBT), Peaceful Nuclear Explosions Treaty (PNET), and Nuclear-Free Zones treaties. The author also discusses his views on what the priorities of arms control activities should be

  15. Beyond arms control? Looking for the lost paradigm.

    International Nuclear Information System (INIS)

    Dahan, P.

    2002-01-01

    Since the tragic events of September 11, 2001, the international relations have become more complex and the arms control concept, born during the cold war and implemented during the 3 last decades is today marking time. Disarmament and non-proliferation, which were the keystones of arms control and international negotiations, are today undergoing erosion. This article analyzes the change of situation between the end of the 20. century and the beginning of the 21. century. Three steps are defined by the author: a 'flux' step with the signature of a huge number of international agreements about non-proliferation and arms control, a stagnation step marked by the difficulties of implementing some of the existing treaties and by the violation by some states of some of them, and a 'reflux' step marked by a freezing up of the bilateral US-Russian disarmament process and a general renouncement of the multilateral arms control concept. (J.S.)

  16. Comparison of upper arm and forearm blood pressure.

    Science.gov (United States)

    Domiano, Kathy L; Hinck, Susan M; Savinske, Debra L; Hope, Kathryn L

    2008-11-01

    The upper arm is the primary site used to obtain a blood pressure measurement (BPM); however, when it is not possible to use the upper arm, the forearm is a commonly used alternate site. This study determines if there is a significant difference between upper arm and forearm BPMs among adults and examines the relationship of participant characteristics to the BPM difference. A convenience sample was recruited from a low-income, independent-living, 104-apartment complex in the Midwest. Of the 106 participants, 64% were female and 89% were White. Ages ranged from 20 to 85 years (M = 50.7). The investigators calculated the BMIs (range = 18 to 42, M = 29.3, SD = 5.4) for the 89% (n = 94) of participants who reported their weight. The forearm tended to have higher BPMs than the upper arm (M difference = 4.0 mm Hg systolic, 2.3 mm Hg diastolic). However, site differences were greatest for men, obese adults, and middle aged (36 to 65) adults.

  17. Radial Head Subluxation: Possible Effective Factors on Time to Re-use the Affected Limb

    Directory of Open Access Journals (Sweden)

    Farhad Heydari

    2018-01-01

    Full Text Available Introduction: Radial head subluxation (RHS is a common disorder in children. Although it is not accompanied by any important short- or long-term sequel, it could make the parents worried about. Objective: The purpose of this study was to determine the possible effective factors that may influence time to use the affected limb. Methods: This cross-sectional study was conducted prospectively during the years 2014 to 2016. All children under the age of 6 years who visited the emergency department (ED and were diagnosed as having RHS were eligible. The patients’ baseline information was recorded. After the reduction, the time until the affected arm use returned was recorded. The possible relationship between the baseline data and time to re-use the affected limb was assessed. Results: During the study period, 112 children with a mean age of 30.18 ± 18.18 months were evaluated (53% male. Among the children who visited the ED during the first 4 hours and thereafter, 84% and 60%, respectively, re-used their limb in less than 10 minutes after reduction (p = 0.004. Also, 55% of children less than or equal to 24 months and 89% over the age of 24 months re-used the arm in 10 minutes (p < 0.001. The success rate of the first reduction maneuver was significantly lower in children with a recurrent dislocation (p = 0.001. Conclusion: It is likely that age less than or equal to 24 months and ED visit after 4 hours of the event lead to a longer duration for re-using the affected arm following reduction.

  18. ARM Operations and Engineering Procedure Mobile Facility Site Startup

    Energy Technology Data Exchange (ETDEWEB)

    Voyles, Jimmy W

    2015-05-01

    This procedure exists to define the key milestones, necessary steps, and process rules required to commission and operate an Atmospheric Radiation Measurement (ARM) Mobile Facility (AMF), with a specific focus toward on-time product delivery to the ARM Data Archive. The overall objective is to have the physical infrastructure, networking and communications, and instrument calibration, grooming, and alignment (CG&A) completed with data products available from the ARM Data Archive by the Operational Start Date milestone.

  19. WORKSPACE DRAWING FROM A MANIPULATOR ARM WITH 6 DOF

    Directory of Open Access Journals (Sweden)

    NAIDIN Gigi

    2011-06-01

    Full Text Available Modelling and simulation is an important aspect in robotic field. Knowing of the workspace is very important to the operation of manipulators arm. This paper investigates operational performance of space manipulator arm destined for industrial manufacturing, by defining and analyzing their workspace and manipulability measure. The authors show that manipulator arm developing requires the consideration of more efficient dynamic models and use of dedicated processing techniques such as Autodesk-Inventor 9, MATLAB, WorkSpace software.

  20. Potential Dermal Exposure in greenhouses for manual sprayers: Analysis of the mix/load, application and re-entry stages

    Energy Technology Data Exchange (ETDEWEB)

    Ramos, Laura M.; Querejeta, Giselle A.; Flores, Andrea P.; Hughes, Enrique A.; Zalts, Anita [Instituto de Ciencias, Universidad Nacional de General Sarmiento (UNGS), J. M. Gutierrez 1150, (B1613GSX) Los Polvorines, Prov. de Buenos Aires (Argentina); Montserrat, Javier M., E-mail: jmontser@ungs.edu.ar [Instituto de Ciencias, Universidad Nacional de General Sarmiento (UNGS), J. M. Gutierrez 1150, (B1613GSX) Los Polvorines, Prov. de Buenos Aires (Argentina); Instituto de Investigaciones en Ingenieria Genetica y Biologia Molecular (CONICET), Vuelta de Obligado 2490, 2o piso, Buenos Aires (Argentina)

    2010-09-01

    An evaluation of the Potential Dermal Exposure for the mix/load, application and re-entry stages, associated with procymidone and deltamethrin usage, was carried out for tomatoes grown in greenhouses of small production units in Argentina. Eight experiments were done with four different operators, under typical field conditions with a lever operated backpack sprayer. The methodology applied was based on the Whole Body Dosimetry technique, evaluating a set of different data for the mix and load, application and re-entry operations. These results indicated that the Potential Dermal Exposure of the application step was (38 {+-} 17) mL h{sup -1} with the highest proportion on torso, head and arms. When the three stages were compared, re-entry was found to contribute least towards the total Potential Dermal Exposure; meanwhile in all cases, except one, the mix/load operation was the stage with highest exposure. The Margin of Safety for each different operation was also calculated and the proportion of pesticide drift from the greenhouse to the environment is presented. These results emphasize the importance of improving the personal protection measures in the mix and load stage, an operation that is not usually associated with high-risk in small production units.

  1. Potential Dermal Exposure in greenhouses for manual sprayers: Analysis of the mix/load, application and re-entry stages

    International Nuclear Information System (INIS)

    Ramos, Laura M.; Querejeta, Giselle A.; Flores, Andrea P.; Hughes, Enrique A.; Zalts, Anita; Montserrat, Javier M.

    2010-01-01

    An evaluation of the Potential Dermal Exposure for the mix/load, application and re-entry stages, associated with procymidone and deltamethrin usage, was carried out for tomatoes grown in greenhouses of small production units in Argentina. Eight experiments were done with four different operators, under typical field conditions with a lever operated backpack sprayer. The methodology applied was based on the Whole Body Dosimetry technique, evaluating a set of different data for the mix and load, application and re-entry operations. These results indicated that the Potential Dermal Exposure of the application step was (38 ± 17) mL h -1 with the highest proportion on torso, head and arms. When the three stages were compared, re-entry was found to contribute least towards the total Potential Dermal Exposure; meanwhile in all cases, except one, the mix/load operation was the stage with highest exposure. The Margin of Safety for each different operation was also calculated and the proportion of pesticide drift from the greenhouse to the environment is presented. These results emphasize the importance of improving the personal protection measures in the mix and load stage, an operation that is not usually associated with high-risk in small production units.

  2. Efficacy and Safety of a Mineral Oil-Based Head Lice Shampoo: A Randomized, Controlled, Investigator-Blinded, Comparative Study.

    Science.gov (United States)

    Wolf, Luise; Eertmans, Frank; Wolf, Doerte; Rossel, Bart; Adriaens, Els

    2016-01-01

    Due to increased resistance and safety concerns with insecticide-based pediculicides, there is growing demand for head lice treatments with a physical mode of action. Certain mineral oils kill lice by blocking spiracles or by disrupting the epicuticular wax layer. The present study was performed to evaluate efficacy and safety of a mineral oil-based shampoo. This randomized, controlled, investigator-blinded, monocentric study (EudraCT registration no. 2014-002918-23) was performed from October 2014-June 2015 in Germany. A mineral oil shampoo (Mosquito® Med Läuse Shampoo 10 in Germany, Paranix or Silcap shampoo elsewhere), registered as medical device, was compared to a conventional, locally reimbursed, pyrethroid-based pediculicide (Goldgeist® Forte solution). In total, 107 patients (>1 year) with confirmed head lice infestation were included (test arm: n = 53; control arm: n = 54). All subjects received two applications of either test or control product at day 0 and day 7, according to the instructions for use. Efficacy and safety was evaluated directly, 1h and 24h after first application, before and after second treatment, and at day 10. The main objective was demonstrating a cure rate for the test product, being superior to 70% at day 10. Cure rates at day 10 (corrected for re-infestation) for the test product (96.1%) and control (94%) significantly exceeded the pre-defined target (70%) (p shampoo) can be safe and effective alternatives for insecticide-based pediculicides, with less risk for development of resistance because of the physical mode of action. German Clinical Trials Register (DRKS) DRKS00009753 and EudraCT database 2014-002918-23.

  3. Chaotic evolution of arms races

    Science.gov (United States)

    Tomochi, Masaki; Kono, Mitsuo

    1998-12-01

    A new set of model equations is proposed to describe the evolution of the arms race, by extending Richardson's model with special emphases that (1) power dependent defensive reaction or historical enmity could be a motive force to promote armaments, (2) a deterrent would suppress the growth of armaments, and (3) the defense reaction of one nation against the other nation depends nonlinearly on the difference in armaments between two. The set of equations is numerically solved to exhibit stationary, periodic, and chaotic behavior depending on the combinations of parameters involved. The chaotic evolution is realized when the economic situation of each country involved in the arms race is quite different, which is often observed in the real world.

  4. Information booklet on personal protective equipment: arm and hand protection

    International Nuclear Information System (INIS)

    1992-01-01

    Fire, heat, cold, electro-magnetic and ionising radiation, electricity, chemicals, impacts, cuts, abrasion, etc. are the common hazards for arms and hands at work. The gloves chosen for protection of the arm and hand should cover those parts adequately and the material of the gloves should be capable of offering protection against the specific hazard involved. Criteria for choosing arm and hand protection equipment will be based on their shape and part of the arm and hand protected. Guide lines for choosing such personal protection equipment for nuclear facilities are given. (M.K.V.). 3 annexures, 1 appendix

  5. The arms race control; Le controle de la course aux armements

    Energy Technology Data Exchange (ETDEWEB)

    Nemo, J.

    2010-07-15

    Written in 1961, this paper presents the content of a book entitled 'The arms race control' where the author outlined the difference between disarmament and arms control, described the economic and moral role of arms race, the importance of force balance for international security. He wandered whether arms control could ensure this balance and whether nuclear balance meant force balance. Force balance then appears to be a precarious and unsteady component of international security. He commented the challenges of disarmament, recalled some arguments for a nuclear disarmament. Then he discussed what would be an arms control with or without disarmament (either nuclear or conventional)

  6. Long-term outcome of segmental reconstruction of the humeral head for the treatment of locked posterior dislocation of the shoulder.

    Science.gov (United States)

    Gerber, Christian; Catanzaro, Sabrina; Jundt-Ecker, Michele; Farshad, Mazda

    2014-11-01

    Locked posterior glenohumeral dislocations with impaction fractures involving less than 30% to 35% of the humeral head are most frequently treated with lesser tuberosity transfer into the defect, whereas those involving more than 35% to 40% are treated with humeral head arthroplasty. As an alternative, reconstruction of the defect with segmental femoral or humeral head allograft has been proposed, but the long-term outcome of this joint-preserving procedure is unknown. Twenty-two shoulders in 21 patients with a locked posterior shoulder dislocation and an impaction of at least 30% (mean, 43%) of the humeral head were treated with segmental reconstruction of the humeral head defect. They were reviewed clinically and radiographically at a minimum follow-up of 5 years. Of the 22 shoulders, 19 could be followed up at 128 months (range, 60-294 months) postoperatively. Only 2 of the 19 patients needed a prosthesis more than 180 months after the index operation. Of the other 17, 4 had radiographically advanced osteoarthritis (OA), 4 had mild OA, and 9 had no or minimal OA. Eighteen shoulders were rated as subjectively excellent, none were rated as good, and one was rated as fair. The final Constant-Murley score averaged 77 points (range, 52-98 points), the Subjective Shoulder Value averaged 88% (range, 75%-100%), and only 2 patients had mild to moderate pain. Mean active anterior elevation was 145°, and mean external rotation with the arm at the side was 42°. Segmental reconstruction of humeral head defects for large anteromedial impaction fractures caused by locked posterior dislocations durably restores stability and freedom from pain with an excellent subjective long-term outcome. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  7. Beyond arms control? Looking for the lost paradigm..; Au-dela de l'arms control? A la recherche du paradigme perdu..

    Energy Technology Data Exchange (ETDEWEB)

    Dahan, P

    2002-07-01

    Since the tragic events of September 11, 2001, the international relations have become more complex and the arms control concept, born during the cold war and implemented during the 3 last decades is today marking time. Disarmament and non-proliferation, which were the keystones of arms control and international negotiations, are today undergoing erosion. This article analyzes the change of situation between the end of the 20. century and the beginning of the 21. century. Three steps are defined by the author: a 'flux' step with the signature of a huge number of international agreements about non-proliferation and arms control, a stagnation step marked by the difficulties of implementing some of the existing treaties and by the violation by some states of some of them, and a 'reflux' step marked by a freezing up of the bilateral US-Russian disarmament process and a general renouncement of the multilateral arms control concept. (J.S.)

  8. Short-arm human centrifugation with 0.4g at eye and 0.75g at heart level provides similar cerebrovascular and cardiovascular responses to standing.

    Science.gov (United States)

    Goswami, Nandu; Bruner, Michelle; Xu, Da; Bareille, Marie-Pierre; Beck, Arnaud; Hinghofer-Szalkay, Helmut; Blaber, Andrew P

    2015-07-01

    Orthostatic intolerance continues to be a problem with astronauts upon return to Earth as a result of cerebral and cardiovascular adaptations to weightlessness. We tested the hypothesis that artificial gravity from a short-arm human centrifuge (SAHC) could provide cerebral and cardiovascular stimuli similar to upright posture and thereby serve as a suitable countermeasure. We compared cardiovascular and cerebrovascular responses before, during, and after exposure to hyper-G with that of standing in healthy young participants. The head was positioned such that the middle cerebral artery (MCA) was 0.46 m from the center of rotation. Two levels of hyper-G that provided 1g and 2g at foot level were investigated. Continuous blood pressure, heart rate, calf blood volume, MCA mean blood flow velocity (MFV) and end-tidal CO2 were measured. Blood pressure at the level of the MCA (BP-MCA) and MFV was reduced during stand and at 2g. The relationship between MFV and BP-MCA at 2g was different from supine and similar to standing, while 1g centrifugation was not different from supine. The cardiovascular system was also not different from supine at 1g but was similarly challenged in 2g compared to stand. Our data suggest that short-arm centrifugation 2g at the feet, with the head offset 0.5 m from the center, provides similar cardiovascular and cerebral responses to standing. This supports the hypothesis that passive 2g SAHC exposure at the feet could be used as a countermeasure for in-flight cardiovascular and cerebrovascular deconditioning.

  9. Concomitant Cisplatin and Hyperfractionated Radiotherapy in Locally Advanced Head and Neck Cancer: 10-Year Follow-Up of a Randomized Phase III Trial (SAKK 10/94)

    International Nuclear Information System (INIS)

    Ghadjar, Pirus; Simcock, Mathew; Studer, Gabriela; Allal, Abdelkarim S.; Ozsahin, Mahmut; Bernier, Jacques; Töpfer, Michael; Zimmermann, Frank; Betz, Michael; Glanzmann, Christoph; Aebersold, Daniel M.

    2012-01-01

    Purpose: To compare the long-term outcome of treatment with concomitant cisplatin and hyperfractionated radiotherapy versus treatment with hyperfractionated radiotherapy alone in patients with locally advanced head and neck cancer. Methods and Materials: From July 1994 to July 2000, a total of 224 patients with squamous cell carcinoma of the head and neck were randomized to receive either hyperfractionated radiotherapy alone (median total dose, 74.4 Gy; 1.2 Gy twice daily; 5 days per week) or the same radiotherapy combined with two cycles of cisplatin (20 mg/m 2 for 5 consecutive days during weeks 1 and 5). The primary endpoint was the time to any treatment failure; secondary endpoints were locoregional failure, metastatic failure, overall survival, and late toxicity assessed according to Radiation Therapy Oncology Group criteria. Results: Median follow-up was 9.5 years (range, 0.1–15.4 years). Median time to any treatment failure was not significantly different between treatment arms (hazard ratio [HR], 1.2 [95% confidence interval {CI}, 0.9–1.7; p = 0.17]). Rates of locoregional failure-free survival (HR, 1.5 [95% CI, 1.1–2.1; p = 0.02]), distant metastasis-free survival (HR, 1.6 [95% CI, 1.1–2.5; p = 0.02]), and cancer-specific survival (HR, 1.6 [95% CI, 1.0–2.5; p = 0.03]) were significantly improved in the combined-treatment arm, with no difference in major late toxicity between treatment arms. However, overall survival was not significantly different (HR, 1.3 [95% CI, 0.9–1.8; p = 0.11]). Conclusions: After long-term follow-up, combined-treatment with cisplatin and hyperfractionated radiotherapy maintained improved rates of locoregional control, distant metastasis-free survival, and cancer-specific survival compared to that of hyperfractionated radiotherapy alone, with no difference in major late toxicity.

  10. Viewing medium affects arm motor performance in 3D virtual environments.

    Science.gov (United States)

    Subramanian, Sandeep K; Levin, Mindy F

    2011-06-30

    2D and 3D virtual reality platforms are used for designing individualized training environments for post-stroke rehabilitation. Virtual environments (VEs) are viewed using media like head mounted displays (HMDs) and large screen projection systems (SPS) which can influence the quality of perception of the environment. We estimated if there were differences in arm pointing kinematics when subjects with and without stroke viewed a 3D VE through two different media: HMD and SPS. Two groups of subjects participated (healthy control, n=10, aged 53.6 ± 17.2 yrs; stroke, n=20, 66.2 ± 11.3 yrs). Arm motor impairment and spasticity were assessed in the stroke group which was divided into mild (n=10) and moderate-to-severe (n=10) sub-groups based on Fugl-Meyer Scores. Subjects pointed (8 times each) to 6 randomly presented targets located at two heights in the ipsilateral, middle and contralateral arm workspaces. Movements were repeated in the same VE viewed using HMD (Kaiser XL50) and SPS. Movement kinematics were recorded using an Optotrak system (Certus, 6 markers, 100 Hz). Upper limb motor performance (precision, velocity, trajectory straightness) and movement pattern (elbow, shoulder ranges and trunk displacement) outcomes were analyzed using repeated measures ANOVAs. For all groups, there were no differences in endpoint trajectory straightness, shoulder flexion and shoulder horizontal adduction ranges and sagittal trunk displacement between the two media. All subjects, however, made larger errors in the vertical direction using HMD compared to SPS. Healthy subjects also made larger errors in the sagittal direction, slower movements overall and used less range of elbow extension for the lower central target using HMD compared to SPS. The mild and moderate-to-severe sub-groups made larger RMS errors with HMD. The only advantage of using the HMD was that movements were 22% faster in the moderate-to-severe stroke sub-group compared to the SPS. Despite the similarity in

  11. Viewing medium affects arm motor performance in 3D virtual environments

    Directory of Open Access Journals (Sweden)

    Subramanian Sandeep K

    2011-06-01

    Full Text Available Abstract Background 2D and 3D virtual reality platforms are used for designing individualized training environments for post-stroke rehabilitation. Virtual environments (VEs are viewed using media like head mounted displays (HMDs and large screen projection systems (SPS which can influence the quality of perception of the environment. We estimated if there were differences in arm pointing kinematics when subjects with and without stroke viewed a 3D VE through two different media: HMD and SPS. Methods Two groups of subjects participated (healthy control, n = 10, aged 53.6 ± 17.2 yrs; stroke, n = 20, 66.2 ± 11.3 yrs. Arm motor impairment and spasticity were assessed in the stroke group which was divided into mild (n = 10 and moderate-to-severe (n = 10 sub-groups based on Fugl-Meyer Scores. Subjects pointed (8 times each to 6 randomly presented targets located at two heights in the ipsilateral, middle and contralateral arm workspaces. Movements were repeated in the same VE viewed using HMD (Kaiser XL50 and SPS. Movement kinematics were recorded using an Optotrak system (Certus, 6 markers, 100 Hz. Upper limb motor performance (precision, velocity, trajectory straightness and movement pattern (elbow, shoulder ranges and trunk displacement outcomes were analyzed using repeated measures ANOVAs. Results For all groups, there were no differences in endpoint trajectory straightness, shoulder flexion and shoulder horizontal adduction ranges and sagittal trunk displacement between the two media. All subjects, however, made larger errors in the vertical direction using HMD compared to SPS. Healthy subjects also made larger errors in the sagittal direction, slower movements overall and used less range of elbow extension for the lower central target using HMD compared to SPS. The mild and moderate-to-severe sub-groups made larger RMS errors with HMD. The only advantage of using the HMD was that movements were 22% faster in the moderate-to-severe stroke sub

  12. Observation of the hypodermic fatty layer of the human torso by computed tomography method

    International Nuclear Information System (INIS)

    Matsuyama, Yoko; Inokuchi, Seiichiro; Suzuki, Masataka

    1984-01-01

    CT images were taken at 7 different longitudinal levels of the torso, and three different body types, which were defined by the Rohrer Index, were discussed. Differences between the sexes were also discussed. 1) Total cross-sectional area: In males, values showed maximum at 2 levels (mid-point of sternum, xiphoid) among 7 levels; and, for females, 2 maximal values appeared at the mid-point of the sternum level and the level of the pubic symphysis. Values at the umbilicus level were smallest in both sexes. 2) Areas of hypodermic fatty layer: Here, the values for males were maximal at the umbilicus level, next largest were found at the lower abdominal level. For females, however, the maximal values appeared at the pubic symphysis and lower abdominal levels and values for the umbilicus level followed in magnitude. 3) Hypodermic fatty layer area ratios to those of the total cross-sectional area: Values here were largest at the umbilicus level in both sexes. For males, the ratio at the lower abdominal level and at the pubic symphysis level followed in this order: For females, the order of magnitude of values was reversed between those two ratios. The most minimal ratio appeared at the level of the xiphoid in both sexes. A tendency towards higher ratios in females than in males was seen at all 7 levels for bodies of the A-type. This was seen, however, only at levels below the upper abdomen for bodies of the C-type, and at all levels, except the umbilicus and lower abdomen, for bodies of the D-type. 4) Thickness of the hypodermic fatty layer: The maximal values in this layer appeared at point F for the superior border, mid-point and xiphoid of sternum levels. For the upper abdominal level, maximal values appeared at point A, and for the umbilicus level, at point D. They were all found at point C for the lower abdominal level and at point A for the pubic symphysis level. (J.P.N.)

  13. Epicardial potentials computed from the body surface potential map using inverse electrocardiography and an individualised torso model improve sensitivity for acute myocardial infarction diagnosis.

    Science.gov (United States)

    Daly, Michael J; Finlay, Dewar D; Guldenring, Daniel; Bond, Raymond R; McCann, Aaron J; Scott, Peter J; Adgey, Jennifer A; Harbinson, Mark T

    2017-12-01

    Epicardial potentials (EPs) derived from the body surface potential map (BSPM) improve acute myocardial infarction (AMI) diagnosis. In this study, we compared EPs derived from the 80-lead BSPM using a standard thoracic volume conductor model (TVCM) with those derived using a patient-specific torso model (PSTM) based on body mass index (BMI). Consecutive patients presenting to both the emergency department and pre-hospital coronary care unit between August 2009 and August 2011 with acute ischaemic-type chest pain at rest were enrolled. At first medical contact, 12-lead electrocardiograms and BSPMs were recorded. The BMI for each patient was calculated. Cardiac troponin T (cTnT) was sampled 12 hours after symptom onset. Patients were excluded from analysis if they had any ECG confounders to interpretation of the ST-segment. A cardiologist assessed the 12-lead ECG for ST-segment elevation myocardial infarction by Minnesota criteria and the BSPM. BSPM ST-elevation (STE) was ⩾0.2 mV in anterior, ⩾0.1 mV in lateral, inferior, right ventricular or high right anterior and ⩾0.05 mV in posterior territories. To derive EPs, the BSPM data were interpolated to yield values at 352 nodes of a Dalhousie torso. Using an inverse solution based on the boundary element method, EPs at 98 cardiac nodes positioned within a standard TVCM were derived. The TVCM was then scaled to produce a PSTM using a model developed from computed tomography in 48 patients of varying BMIs, and EPs were recalculated. EPs >0.3 mV defined STE. A cardiologist blinded to both the 12-lead ECG and BSPM interpreted the EP map. AMI was defined as cTnT ⩾0.1 µg/L. Enrolled were 400 patients (age 62 ± 13 years; 57% male); 80 patients had exclusion criteria. Of the remaining 320 patients, the BMI was an average of 27.8 ± 5.6 kg/m 2 . Of these, 180 (56%) had AMI. Overall, 132 had Minnesota STE on ECG (sensitivity 65%, specificity 89%) and 160 had BSPM STE (sensitivity 81%, specificity 90

  14. Coat of Arms.

    Science.gov (United States)

    Smith, Bryan

    1998-01-01

    Describes an activity, the "coat of arms," that can serve as an ice-breaker or warm-up for the first day of an English-as-a-Second/Foreign-Language class, as a motivating start to the week, or act as an innovative segue between skill lessons. The technique can be adapted for students ranging from elementary school to adult language learners of all…

  15. The MVACS Robotic Arm Camera

    Science.gov (United States)

    Keller, H. U.; Hartwig, H.; Kramm, R.; Koschny, D.; Markiewicz, W. J.; Thomas, N.; Fernades, M.; Smith, P. H.; Reynolds, R.; Lemmon, M. T.; Weinberg, J.; Marcialis, R.; Tanner, R.; Boss, B. J.; Oquest, C.; Paige, D. A.

    2001-08-01

    The Robotic Arm Camera (RAC) is one of the key instruments newly developed for the Mars Volatiles and Climate Surveyor payload of the Mars Polar Lander. This lightweight instrument employs a front lens with variable focus range and takes images at distances from 11 mm (image scale 1:1) to infinity. Color images with a resolution of better than 50 μm can be obtained to characterize the Martian soil. Spectral information of nearby objects is retrieved through illumination with blue, green, and red lamp sets. The design and performance of the camera are described in relation to the science objectives and operation. The RAC uses the same CCD detector array as the Surface Stereo Imager and shares the readout electronics with this camera. The RAC is mounted at the wrist of the Robotic Arm and can characterize the contents of the scoop, the samples of soil fed to the Thermal Evolved Gas Analyzer, the Martian surface in the vicinity of the lander, and the interior of trenches dug out by the Robotic Arm. It can also be used to take panoramic images and to retrieve stereo information with an effective baseline surpassing that of the Surface Stereo Imager by about a factor of 3.

  16. a New Generation Mining Head with Disc Tool of Complex Trajectory / GŁOWICA URABIAJĄCA Nowej Generacji Z NARZĘDZIAMI Dyskowymi O ZŁOŻONEJ Trajektorii

    Science.gov (United States)

    Gospodarczyk, Piotr; Kotwica, Krzysztof; Stopka, Grzegorz

    2013-12-01

    In Polish underground mining plenty of dog headings are drilled with mechanical methods with the use of arm roadheaders equipped with milling units. Cutting tools applied on the units - rotary tangent bits in unfavourable mining and geological conditions or improper work conditions are affected by an accelerated wear process. It influences the speed and costs of drilling such excavations. The article presents a new and innovative solution of a mining head with asymmetric disc tools of complex trajectory elaborated at the Department of Mining, Dressing and Transport Machines, AGH University of Science and Technology, Krakow as an alternative for standard milling units. Advantages of the applied mining method using so called back incision were described as well as principles of construction and work of the suggested solution of the head. In order to work out a construction of the head prototype it was necessary to determine principles and guidelines based on laboratory tests. A construction of a specially prepared laboratory stand for examination of disc tools of complex trajectory, planned research methodology, course of tests and obtained results were presented. An analysis of the results allowed determining the above listed principles and guidelines for a construction of a prototype head. They were the base to work out, with cooperation of the REMAG Ltd Company in Katowice, a technical project of a new head solution, adapted for mounting on the arm of a medium arm roadheader KR 150. A constructed head underwent tests on a research stand on the REMAG testing area and received positive preliminary tests results. W polskim górnictwie podziemnym bardzo duża liczba wyrobisk korytarzowych drążona jest metodami mechanicznymi z wykorzystaniem ramionowych kombajnów chodnikowych, wyposażonych w organy frezujące. Stosowane na tych organach narzędzia skrawające - noże styczno-obrotowe, w niekorzystnych warunkach górniczo-geologicznych lub przy nieprawid

  17. Hysteresis of targeting civilians in armed conflicts

    OpenAIRE

    Uih Ran Lee

    2015-01-01

    This article explores warring groups’ intentional targeting behavior against civilians, a strictly prohibited war strategy by international norms. Using dynamic panel regressions run on a comprehensive dataset of contemporary warfare which covers 22 years (1989-2010), I find that warring actors, both sovereign states and formally organized armed groups, behave systematically in terms of civilian targeting when they are involved in prolonged armed conflict (15-22 years). Warring actors’ lethal...

  18. Reactor vessel head permanent shield

    International Nuclear Information System (INIS)

    Hankinson, M.F.; Leduc, R.J.; Richard, J.W.; Malandra, L.J.

    1989-01-01

    A nuclear reactor is described comprising: a nuclear reactor pressure vessel closure head; control rod drive mechanisms (CRDMs) disposed within the closure head so as to project vertically above the closure head; cooling air baffle means surrounding the control rod drive mechanisms for defining cooling air paths relative to the control rod drive mechanisms; means defined within the periphery of the closure head for accommodating fastening means for securing the closure head to its associated pressure vessel; lifting lugs fixedly secured to the closure head for facilitating lifting and lowering movements of the closure head relative to the pressure vessel; lift rods respectively operatively associated with the plurality of lifting lugs for transmitting load forces, developed during the lifting and lowering movements of the closure head, to the lifting lugs; upstanding radiation shield means interposed between the cooling air baffle means and the periphery of the enclosure head of shielding maintenance personnel operatively working upon the closure head fastening means from the effects of radiation which may emanate from the control rod drive mechanisms and the cooling air baffle means; and connecting systems respectively associated with each one of the lifting lugs and each one of the lifting rods for connecting each one of the lifting rods to a respective one of each one of the lifting lugs, and for simultaneously connecting a lower end portion of the upstanding radiation shield means to each one of the respective lifting lugs

  19. Phase III Randomized Trial of Induction Chemotherapy in Patients With N2 or N3 Locally Advanced Head and Neck Cancer

    Science.gov (United States)

    Cohen, Ezra E.W.; Karrison, Theodore G.; Kocherginsky, Masha; Mueller, Jeffrey; Egan, Robyn; Huang, Chao H.; Brockstein, Bruce E.; Agulnik, Mark B.; Mittal, Bharat B.; Yunus, Furhan; Samant, Sandeep; Raez, Luis E.; Mehra, Ranee; Kumar, Priya; Ondrey, Frank; Marchand, Patrice; Braegas, Bettina; Seiwert, Tanguy Y.; Villaflor, Victoria M.; Haraf, Daniel J.; Vokes, Everett E.

    2014-01-01

    Purpose Induction chemotherapy (IC) before radiotherapy lowers distant failure (DF) rates in locally advanced squamous cell carcinoma of the head and neck (SCCHN). The goal of this phase III trial was to determine whether IC before chemoradiotherapy (CRT) further improves survival compared with CRT alone in patients with N2 or N3 disease. Patients and Methods Treatment-naive patients with nonmetastatic N2 or N3 SCCHN were randomly assigned to CRT alone (CRT arm; docetaxel, fluorouracil, and hydroxyurea plus radiotherapy 0.15 Gy twice per day every other week) versus two 21-day cycles of IC (docetaxel 75 mg/m2 on day 1, cisplatin 75 mg/m2 on day 1, and fluorouracil 750 mg/m2 on days 1 to 5) followed by the same CRT regimen (IC + CRT arm). The primary end point was overall survival (OS). Secondary end points included DF-free survival, failure pattern, and recurrence-free survival (RFS). Results A total of 285 patients were randomly assigned. The most common grade 3 to 4 toxicities during IC were febrile neutropenia (11%) and mucositis (9%); during CRT (both arms combined), they were mucositis (49%), dermatitis (21%), and leukopenia (18%). Serious adverse events were more common in the IC arm (47% v 28%; P = .002). With a minimum follow-up of 30 months, there were no statistically significant differences in OS (hazard ratio, 0.91; 95% CI, 0.59 to 1.41), RFS, or DF-free survival. Conclusion IC did not translate into improved OS compared with CRT alone. However, the study was underpowered because it did not meet the planned accrual target, and OS was higher than predicted in both arms. IC cannot be recommended routinely in patients with N2 or N3 locally advanced SCCHN. PMID:25049329

  20. Phase III randomized trial of induction chemotherapy in patients with N2 or N3 locally advanced head and neck cancer.

    Science.gov (United States)

    Cohen, Ezra E W; Karrison, Theodore G; Kocherginsky, Masha; Mueller, Jeffrey; Egan, Robyn; Huang, Chao H; Brockstein, Bruce E; Agulnik, Mark B; Mittal, Bharat B; Yunus, Furhan; Samant, Sandeep; Raez, Luis E; Mehra, Ranee; Kumar, Priya; Ondrey, Frank; Marchand, Patrice; Braegas, Bettina; Seiwert, Tanguy Y; Villaflor, Victoria M; Haraf, Daniel J; Vokes, Everett E

    2014-09-01

    Induction chemotherapy (IC) before radiotherapy lowers distant failure (DF) rates in locally advanced squamous cell carcinoma of the head and neck (SCCHN). The goal of this phase III trial was to determine whether IC before chemoradiotherapy (CRT) further improves survival compared with CRT alone in patients with N2 or N3 disease. Treatment-naive patients with nonmetastatic N2 or N3 SCCHN were randomly assigned to CRT alone (CRT arm; docetaxel, fluorouracil, and hydroxyurea plus radiotherapy 0.15 Gy twice per day every other week) versus two 21-day cycles of IC (docetaxel 75 mg/m(2) on day 1, cisplatin 75 mg/m(2) on day 1, and fluorouracil 750 mg/m(2) on days 1 to 5) followed by the same CRT regimen (IC + CRT arm). The primary end point was overall survival (OS). Secondary end points included DF-free survival, failure pattern, and recurrence-free survival (RFS). A total of 285 patients were randomly assigned. The most common grade 3 to 4 toxicities during IC were febrile neutropenia (11%) and mucositis (9%); during CRT (both arms combined), they were mucositis (49%), dermatitis (21%), and leukopenia (18%). Serious adverse events were more common in the IC arm (47% v 28%; P = .002). With a minimum follow-up of 30 months, there were no statistically significant differences in OS (hazard ratio, 0.91; 95% CI, 0.59 to 1.41), RFS, or DF-free survival. IC did not translate into improved OS compared with CRT alone. However, the study was underpowered because it did not meet the planned accrual target, and OS was higher than predicted in both arms. IC cannot be recommended routinely in patients with N2 or N3 locally advanced SCCHN. © 2014 by American Society of Clinical Oncology.