WorldWideScience

Sample records for head rotation evoked

  1. Head Rotation Detection in Marmoset Monkeys

    Science.gov (United States)

    Simhadri, Sravanthi

    Head movement is known to have the benefit of improving the accuracy of sound localization for humans and animals. Marmoset is a small bodied New World monkey species and it has become an emerging model for studying the auditory functions. This thesis aims to detect the horizontal and vertical rotation of head movement in marmoset monkeys. Experiments were conducted in a sound-attenuated acoustic chamber. Head movement of marmoset monkey was studied under various auditory and visual stimulation conditions. With increasing complexity, these conditions are (1) idle, (2) sound-alone, (3) sound and visual signals, and (4) alert signal by opening and closing of the chamber door. All of these conditions were tested with either house light on or off. Infra-red camera with a frame rate of 90 Hz was used to capture of the head movement of monkeys. To assist the signal detection, two circular markers were attached to the top of monkey head. The data analysis used an image-based marker detection scheme. Images were processed using the Computation Vision Toolbox in Matlab. The markers and their positions were detected using blob detection techniques. Based on the frame-by-frame information of marker positions, the angular position, velocity and acceleration were extracted in horizontal and vertical planes. Adaptive Otsu Thresholding, Kalman filtering and bound setting for marker properties were used to overcome a number of challenges encountered during this analysis, such as finding image segmentation threshold, continuously tracking markers during large head movement, and false alarm detection. The results show that the blob detection method together with Kalman filtering yielded better performances than other image based techniques like optical flow and SURF features .The median of the maximal head turn in the horizontal plane was in the range of 20 to 70 degrees and the median of the maximal velocity in horizontal plane was in the range of a few hundreds of degrees per

  2. Visual perception of axes of head rotation

    Science.gov (United States)

    Arnoldussen, D. M.; Goossens, J.; van den Berg, A. V.

    2013-01-01

    Registration of ego-motion is important to accurately navigate through space. Movements of the head and eye relative to space are registered through the vestibular system and optical flow, respectively. Here, we address three questions concerning the visual registration of self-rotation. (1) Eye-in-head movements provide a link between the motion signals received by sensors in the moving eye and sensors in the moving head. How are these signals combined into an ego-rotation percept? We combined optic flow of simulated forward and rotational motion of the eye with different levels of eye-in-head rotation for a stationary head. We dissociated simulated gaze rotation and head rotation by different levels of eye-in-head pursuit. We found that perceived rotation matches simulated head- not gaze-rotation. This rejects a model for perceived self-rotation that relies on the rotation of the gaze line. Rather, eye-in-head signals serve to transform the optic flow's rotation information, that specifies rotation of the scene relative to the eye, into a rotation relative to the head. This suggests that transformed visual self-rotation signals may combine with vestibular signals. (2) Do transformed visual self-rotation signals reflect the arrangement of the semi-circular canals (SCC)? Previously, we found sub-regions within MST and V6+ that respond to the speed of the simulated head rotation. Here, we re-analyzed those Blood oxygenated level-dependent (BOLD) signals for the presence of a spatial dissociation related to the axes of visually simulated head rotation, such as have been found in sub-cortical regions of various animals. Contrary, we found a rather uniform BOLD response to simulated rotation along the three SCC axes. (3) We investigated if subject's sensitivity to the direction of the head rotation axis shows SCC axes specifcity. We found that sensitivity to head rotation is rather uniformly distributed, suggesting that in human cortex, visuo-vestibular integration is

  3. Visual perception of axes of head rotation

    Directory of Open Access Journals (Sweden)

    David Mattijs Arnoldussen

    2013-02-01

    Full Text Available Registration of ego-motion is important to accurately navigate through space. Movements of the head and eye relative to space are registered through the vestibular system and optical flow, respectively. Here, we address three questions concerning the visual registration of self-rotation. 1. Eye-in-head movements provide a link between the motion signals received by sensors in the moving eye and sensors in the moving head. How are these signals combined into an ego-rotation percept? We combined optic flow of simulated forward and rotational motion of the eye with different levels of eye-in-head rotation for a stationary head. We dissociated simulated gaze rotation and head rotation by different levels of eye-in-head pursuit.We found that perceived rotation matches simulated head- not gaze-rotation. This rejects a model for perceived self-rotation that relies on the rotation of the gaze line. Rather, eye-in-head signals serve to transform the optic flow’s rotation information, that specifies rotation of the scene relative to the eye, into a rotation relative to the head. This suggests that transformed visual self-rotation signals may combine with vestibular signals.2. Do transformed visual self-rotation signals reflect the arrangement of the semicircular canals (SCC? Previously, we found sub-regions within MST and V6+ that respond to the speed of the simulated head rotation. Here, we re-analyzed those BOLD signals for the presence of a spatial dissociation related to the axes of visually simulated head rotation, such as have been found in sub-cortical regions of various animals. Contrary, we found a rather uniform BOLD response to simulated rotation along the three SCC axes.3. We investigated if subject’s sensitivity to the direction of the head rotation axis shows SCC axes specifcity. We found that sensitivity to head rotation is rather uniformly distributed, suggesting that in human cortex, visuo-vestibular integration is not arranged into

  4. Coordination of eye and head components of movements evoked by stimulation of the paramedian pontine reticular formation

    Science.gov (United States)

    Barton, Ellen J.; Sparks, David L.

    2013-01-01

    Constant frequency microstimulation of the paramedian pontine reticular formation (PPRF) in head-restrained monkeys evokes a constant velocity eye movement. Since the PPRF receives significant projections from structures that control coordinated eye-head movements, we asked whether stimulation of the pontine reticular formation in the head-unrestrained animal generates a combined eye-head movement or only an eye movement. Microstimulation of most sites yielded a constant-velocity gaze shift executed as a coordinated eye-head movement, although eye-only movements were evoked from some sites. The eye and head contributions to the stimulation-evoked movements varied across stimulation sites and were drastically different from the lawful relationship observed for visually-guided gaze shifts. These results indicate that the microstimulation activated elements that issued movement commands to the extraocular and, for most sites, neck motoneurons. In addition, the stimulation-evoked changes in gaze were similar in the head-restrained and head-unrestrained conditions despite the assortment of eye and head contributions, suggesting that the vestibuloocular reflex (VOR) gain must be near unity during the coordinated eye-head movements evoked by stimulation of the PPRF. These findings contrast the attenuation of VOR gain associated with visually-guided gaze shifts and suggest that the vestibulo-ocular pathway processes volitional and PPRF stimulation-evoked gaze shifts differently. PMID:18458891

  5. The Cervical Vestibular-Evoked Myogenic Potentials (cVEMPs) Recorded Along the Sternocleidomastoid Muscles During Head Rotation and Flexion in Normal Human Subjects.

    Science.gov (United States)

    Ashford, Alexander; Huang, Jun; Zhang, Chunming; Wei, Wei; Mustain, William; Eby, Thomas; Zhu, Hong; Zhou, Wu

    2016-08-01

    Tone burst-evoked myogenic potentials recorded from tonically contracted sternocleidomastoid muscles (SCM) (cervical VEMP or cVEMP) are widely used to assess the vestibular function. Since the cVEMP response is mediated by the vestibulo-collic reflex (VCR) pathways, it is important to understand how the cVEMPs are determined by factors related to either the sensory components (vestibular end organs) or the motor components (SCM) of the VCR pathways. Compared to the numerous studies that have investigated effects of sound parameters on the cVEMPs, there are few studies that have examined effects of SCM-related factors on the cVEMPs. The goal of the present study is to fill this knowledge gap by testing three SCM-related hypotheses. The first hypothesis is that contrary to the current view, the cVEMP response is only present in the SCM ipsilateral to the stimulated ear. The second hypothesis is that the cVEMP response is not only dependent on tonic level of the SCM, but also on how the tonic level is achieved, i.e., by head rotation or head flexion. The third hypothesis is that the SCM is compartmented and the polarity of the cVEMP response is dependent on the recording site. Seven surface electrodes were positioned along the left SCMs in 12 healthy adult subjects, and tone bursts were delivered to the ipsilateral or contralateral ear (8 ms plateau, 1 ms rise/fall, 130 dB SPL, 50-4000 Hz) while subjects activated their SCMs by head rotation (HR condition) or chin downward head flexion (CD condition). The first hypothesis was confirmed by the finding that the contralateral cVEMPs were minimal at all recording sites for all the tested tones during both HR and CD conditions. The second hypothesis was confirmed by the finding that the ipsilateral cVEMPs were larger in HR condition than in CD condition at recording sites above and below the SCM midpoint. Finally, the third hypothesis was confirmed by the finding that the cVEMPs exhibit reversed polarities at the sites

  6. Head movements evoked in alert rhesus monkey by vestibular prosthesis stimulation: implications for postural and gaze stabilization.

    Directory of Open Access Journals (Sweden)

    Diana E Mitchell

    Full Text Available The vestibular system detects motion of the head in space and in turn generates reflexes that are vital for our daily activities. The eye movements produced by the vestibulo-ocular reflex (VOR play an essential role in stabilizing the visual axis (gaze, while vestibulo-spinal reflexes ensure the maintenance of head and body posture. The neuronal pathways from the vestibular periphery to the cervical spinal cord potentially serve a dual role, since they function to stabilize the head relative to inertial space and could thus contribute to gaze (eye-in-head + head-in-space and posture stabilization. To date, however, the functional significance of vestibular-neck pathways in alert primates remains a matter of debate. Here we used a vestibular prosthesis to 1 quantify vestibularly-driven head movements in primates, and 2 assess whether these evoked head movements make a significant contribution to gaze as well as postural stabilization. We stimulated electrodes implanted in the horizontal semicircular canal of alert rhesus monkeys, and measured the head and eye movements evoked during a 100 ms time period for which the contribution of longer latency voluntary inputs to the neck would be minimal. Our results show that prosthetic stimulation evoked significant head movements with latencies consistent with known vestibulo-spinal pathways. Furthermore, while the evoked head movements were substantially smaller than the coincidently evoked eye movements, they made a significant contribution to gaze stabilization, complementing the VOR to ensure that the appropriate gaze response is achieved. We speculate that analogous compensatory head movements will be evoked when implanted prosthetic devices are transitioned to human patients.

  7. Axis of eye rotation changes with head-pitch orientation during head impulses about earth-vertical.

    Science.gov (United States)

    Migliaccio, Americo A; Schubert, Michael C; Clendaniel, Richard A; Carey, John P; Della Santina, Charles C; Minor, Lloyd B; Zee, David S

    2006-06-01

    The goal of this study was to assess how the axis of head rotation, Listing's law, and eye position influence the axis of eye rotation during brief, rapid head rotations. We specifically asked how the axis of eye rotation during the initial angular vestibuloocular reflex (VOR) changed when the pitch orientation of the head relative to Earth-vertical was varied, but the initial position of the eye in the orbit and the orientation of Listing's plane with respect to the head were fixed. We measured three-dimensional eye and head rotation axes in eight normal humans using the search coil technique during head-and-trunk (whole-body) and head-on-trunk (head-only) "impulses" about an Earth-vertical axis. The head was initially oriented at one of five pitch angles (30 degrees nose down, 15 degrees nose down, 0 degrees, 15 degrees nose up, 30 degrees nose up). The fixation target was always aligned with the nasooccipital axis. Whole-body impulses were passive, unpredictable, manual, rotations with peak-amplitude of approximately 20 degrees , peak-velocity of approximately 80 degrees /s, and peak-acceleration of approximately 1000 degrees /s2. Head-only impulses were also passive, unpredictable, manual, rotations with peak-amplitude of approximately 20 degrees , peak-velocity of approximately 150 degrees /s, and peak-acceleration of approximately 3000 degrees /s2. During whole-body impulses, the axis of eye rotation tilted in the same direction, and by an amount proportional (0.51 +/- 0.09), to the starting pitch head orientation (P rotation could be predicted from vectorial summation of the gains (eye velocity/head velocity) obtained for rotations about the pure yaw and roll head axes. Thus, even when the orientation of Listing's plane and eye position in the orbit are fixed, the axis of eye rotation during the VOR reflects a compromise between the requirements of Listing's law and a perfectly compensatory VOR.

  8. Effects of Sustained Otolith-Only Stimulation on Post-Rotational Nystagmus.

    Science.gov (United States)

    Shaikh, Aasef G; Solomon, David

    2017-06-01

    Constant velocity rotations in darkness evoke vestibulo-ocular reflex in form of pre- and post-rotational nystagmus under cerebellar supervision. Reorientation of the head with respect to gravity, stimulating otolith and semicircular canal, during post-rotational phase rapidly suppresses the post-rotational nystagmus. We asked if pure otolith stimulation without semicircular canal signal is sufficient for the suppression of post-rotational nystagmus. The experimental paradigm comprised of on-axis rotations in the horizontal plane when the subject was sitting upright, followed by a novel stimulus that combined off-axis centrifugation in the horizontal plane with amplitude matched, yet out-of-phase, on-axis horizontal rotation-double centrifugation. The resultant effect of double centrifugation was pure otolith stimulation that constantly changed direction, yet completely canceled out angular velocity (no horizontal semicircular canal stimulation). Double centrifugation without pre-existing on-axis rotations evoked mixture of horizontal and vertical eye movements, latter reflected the known uncertainty of the vestibular system to differentiate whether the sensory signal is related to low-frequency translations in horizontal plane or head tilts relative to the gravity. Double centrifugation during post-rotational phase suppressed the peak slow phase eye velocity of the post-rotational nystagmus, hence affecting the vestibular ocular reflex gain (eye velocity/head velocity) matrix. The decay time constant, however, was unchanged. Amount of suppression of the peak slow phase eye velocity of the post-rotational nystagmus during double centrifugation correlated with the peak vertical eye velocity evoked by the pure otolith stimuli in the absence of pre-existing on axis rotations. In post-rotational phase, the pure otolith signal affects vestibular ocular reflex gain matrix but does not affect the time constant.

  9. Rotational Acceleration during Head Impact Resulting from Different Judo Throwing Techniques

    OpenAIRE

    MURAYAMA, Haruo; HITOSUGI, Masahito; MOTOZAWA, Yasuki; OGINO, Masahiro; KOYAMA, Katsuhiro

    2014-01-01

    Most severe head injuries in judo are reported as acute subdural hematoma. It is thus necessary to examine the rotational acceleration of the head to clarify the mechanism of head injuries. We determined the rotational acceleration of the head when the subject is thrown by judo techniques. One Japanese male judo expert threw an anthropomorphic test device using two throwing techniques, Osoto-gari and Ouchigari. Rotational and translational head accelerations were measured with and without an ...

  10. Effect of head rotation in whiplash-type rear impacts.

    Science.gov (United States)

    Kumar, Shrawan; Ferrari, Robert; Narayan, Yogesh

    2005-01-01

    Knowledge is increasing about the electromyographic and kinematic response of the neck muscles to rear impact, and also recent information is available on the effect of a rear impact offset to the left (posterolateral). The effect of head rotation, however, at the time of rear impact is not known. The purpose of this study was to examine the effects of head rotation to the left and right on the cervical muscle response to increasing low-velocity posterolateral impacts. Twenty healthy volunteers were subjected to rear impacts of 4.7, 8.3, 10.9 and 13.7 m/s2 acceleration, offset by 45 degrees to the subject's left, with head rotation to right and left. Bilateral electromyograms of the sternocleidomastoids, trapezii and splenii capitis were recorded. Triaxial accelerometers recorded the acceleration of the sled, torso at the shoulder level, and head of the participant. With the head rotated to the right, at an acceleration of 13.7 m/s2, the left sternocleidomastoid generated 59% and the right sternocleidomastoid 20% of their maximal voluntary contraction (MVC) electromyogram (EMG). Under these conditions, the remaining muscles (both splenii capitis and trapezius) generated 25% or less of their MVC. With the head rotated to the left, at an acceleration of 13.7 m/s2, the right sternocleidomastoid generated 65% and the left sternocleidomastoid only 11% of the MVC EMG. Under these conditions, again the remaining muscles had low EMG activity (27% or less) with the exception of the left trapezius which generated 47% of its MVC. Electromyographic variables were significantly affected by the levels of acceleration (pfactor in determining the muscle response to whiplash, but head rotation at the time of impact is also important in this regard. More specifically, when a rear impact is left posterolateral, it results in increased EMG generation mainly in the contralateral sternocleidomastoid, as expected, but head rotation at the same time in this type of impact reduces the EMG

  11. Three-dimensional motion of the uncovertebral joint during head rotation.

    Science.gov (United States)

    Nagamoto, Yukitaka; Ishii, Takahiro; Iwasaki, Motoki; Sakaura, Hironobu; Moritomo, Hisao; Fujimori, Takahito; Kashii, Masafumi; Murase, Tsuyoshi; Yoshikawa, Hideki; Sugamoto, Kazuomi

    2012-10-01

    The uncovertebral joints are peculiar but clinically important anatomical structures of the cervical vertebrae. In the aged or degenerative cervical spine, osteophytes arising from an uncovertebral joint can cause cervical radiculopathy, often necessitating decompression surgery. Although these joints are believed to bear some relationship to head rotation, how the uncovertebral joints work during head rotation remains unclear. The purpose of this study is to elucidate 3D motion of the uncovertebral joints during head rotation. Study participants were 10 healthy volunteers who underwent 3D MRI of the cervical spine in 11 positions during head rotation: neutral (0°) and 15° increments to maximal head rotation on each side (left and right). Relative motions of the cervical spine were calculated by automatically superimposing a segmented 3D MR image of the vertebra in the neutral position over images of each position using the volume registration method. The 3D intervertebral motions of all 10 volunteers were standardized, and the 3D motion of uncovertebral joints was visualized on animations using data for the standardized motion. Inferred contact areas of uncovertebral joints were also calculated using a proximity mapping technique. The 3D animation of uncovertebral joints during head rotation showed that the joints alternate between contact and separation. Inferred contact areas of uncovertebral joints were situated directly lateral at the middle cervical spine and dorsolateral at the lower cervical spine. With increasing angle of rotation, inferred contact areas increased in the middle cervical spine, whereas areas in the lower cervical spine slightly decreased. In this study, the 3D motions of uncovertebral joints during head rotation were depicted precisely for the first time.

  12. Rotational acceleration during head impact resulting from different judo throwing techniques.

    Science.gov (United States)

    Murayama, Haruo; Hitosugi, Masahito; Motozawa, Yasuki; Ogino, Masahiro; Koyama, Katsuhiro

    2014-01-01

    Most severe head injuries in judo are reported as acute subdural hematoma. It is thus necessary to examine the rotational acceleration of the head to clarify the mechanism of head injuries. We determined the rotational acceleration of the head when the subject is thrown by judo techniques. One Japanese male judo expert threw an anthropomorphic test device using two throwing techniques, Osoto-gari and Ouchi-gari. Rotational and translational head accelerations were measured with and without an under-mat. For Osoto-gari, peak resultant rotational acceleration ranged from 4,284.2 rad/s(2) to 5,525.9 rad/s(2) and peak resultant translational acceleration ranged from 64.3 g to 87.2 g; for Ouchi-gari, the accelerations respectively ranged from 1,708.0 rad/s(2) to 2,104.1 rad/s(2) and from 120.2 g to 149.4 g. The resultant rotational acceleration did not decrease with installation of an under-mat for both Ouchi-gari and Osoto-gari. We found that head contact with the tatami could result in the peak values of translational and rotational accelerations, respectively. In general, because kinematics of the body strongly affects translational and rotational accelerations of the head, both accelerations should be measured to analyze the underlying mechanism of head injury. As a primary preventative measure, throwing techniques should be restricted to participants demonstrating ability in ukemi techniques to avoid head contact with the tatami.

  13. Rotating head for air, gas and mud drilling

    Energy Technology Data Exchange (ETDEWEB)

    Pruitt, A.B.

    1983-05-17

    A rotating head assembly having roller thrust bearings rotatably journaling an inner barrel is provided with pump means for continuous forced circulation of lubricating oil to, and around, the thrust bearings during operation. A lubricating oil chamber substantially surrounds the bearings, which chamber is effectively sealed against leakage of oil fluids, and other debris, into the chamber and lubricating oil out of the chamber. The lower end of the rotatably journaled inner barrel is provided with a stripper rubber structured to enable use of the head with drill pipe of diverse outer diameters.

  14. Brain state-dependence of electrically evoked potentials monitored with head-mounted electronics.

    Science.gov (United States)

    Richardson, Andrew G; Fetz, Eberhard E

    2012-11-01

    Inferring changes in brain connectivity is critical to studies of learning-related plasticity and stimulus-induced conditioning of neural circuits. In addition, monitoring spontaneous fluctuations in connectivity can provide insight into information processing during different brain states. Here, we quantified state-dependent connectivity changes throughout the 24-h sleep-wake cycle in freely behaving monkeys. A novel, head-mounted electronic device was used to electrically stimulate at one site and record evoked potentials at other sites. Electrically evoked potentials (EEPs) revealed the connectivity pattern between several cortical sites and the basal forebrain. We quantified state-dependent changes in the EEPs. Cortico-cortical EEP amplitude increased during slow-wave sleep, compared to wakefulness, while basal-cortical EEP amplitude decreased. The results demonstrate the utility of using portable electronics to document state-dependent connectivity changes in freely behaving primates.

  15. Effect of head rotation on cerebral blood velocity in the prone position

    DEFF Research Database (Denmark)

    Højlund, Jakob; Sandmand, Marie; Sonne, Morten

    2012-01-01

    for cerebral blood flow. We tested in healthy subjects the hypothesis that rotating the head in the prone position reduces cerebral blood flow. Methods. Mean arterial blood pressure (MAP), stroke volume (SV), and CO were determined, together with the middle cerebral artery mean blood velocity (MCA V...... V(mean) ~10% in spite of an elevated MAP. Prone positioning with rotated head affects both CBF and cerebrovenous drainage indicating that optimal brain perfusion requires head centering....

  16. A morphological comparison of the piriform sinuses in head-on and head-rotated views of seated subjects using cone-beam computed tomography

    International Nuclear Information System (INIS)

    Yamashina, Atsushi; Tanimoto, Keiji; Ohtsuka, Masahiko; Nagasaki, Toshikazu; Sutthiprapaporn, Pipop; Iida, Yukihiro; Katsumata, Akitoshi

    2008-01-01

    Food flow in the oropharynx changes when the head is rotated. The purpose of this study was to evaluate morphological differences in the upper and lower piriform sinuses in head-on (HO) versus head-rotated (HR) positions. Ten healthy adult volunteers with no previous history of dysphagia were subjected to cone-beam computed tomography (CBCT) in the HO and HR positions. Binary CBCT images were created at 50% gray scale to examine morphological changes in the lower piriform sinuses. Upon rotation to the right, the cross-sectional area of the left lower piriform sinus increased significantly (P=0.037). The depth of the right lower piriform sinus also increased significantly (P=0.011) upon rotation. The volume of the lower piriform sinuses increased significantly on both sides (right, P=0.009; left, P=0.013). The upper piriform sinuses acquired a teardrop shape, with the rotated side narrowed and opposite side enlarged. These results suggest that changes in food flow during head rotation result mainly from changes in the size and shape of the upper piriform sinuses. (author)

  17. Optic Flow Information Influencing Heading Perception during Rotation

    Directory of Open Access Journals (Sweden)

    Diederick C. Niehorster

    2011-05-01

    Full Text Available We investigated what roles global spatial frequency, surface structure, and foreground motion play in heading perception during simulated rotation from optic flow. The display (110°Hx94°V simulated walking on a straight path over a ground plane (depth range: 1.4–50 m at 2 m/s while fixating a target off to one side (mean R/T ratios: ±1, ±2, ±3 under six display conditions. Four displays consisted of nonexpanding dots that were distributed so as to manipulate the amount of foreground motion and the presence of surface structure. In one further display the ground was covered with disks that expanded during the trial and lastly a textured ground display was created with the same spatial frequency power spectrum as the disk ground. At the end of each 1s trial, observers indicated their perceived heading along a line at the display's center. Mean heading biases were smaller for the textured than for the disk ground, for the displays with more foreground motion and for the displays with surface structure defined by dot motion than without. We conclude that while spatial frequency content is not a crucial factor, dense motion parallax and surface structure in optic flow are important for accurate heading perception during rotation.

  18. Analysis of right anterolateral impacts: the effect of head rotation on the cervical muscle whiplash response

    Directory of Open Access Journals (Sweden)

    Narayan Yogesh

    2005-05-01

    Full Text Available Abstract Background The cervical muscles are considered a potential site of whiplash injury, and there are many impact scenarios for whiplash injury. There is a need to understand the cervical muscle response under non-conventional whiplash impact scenarios, including variable head position and impact direction. Methods Twenty healthy volunteers underwent right anterolateral impacts of 4.0, 7.6, 10.7, and 13.0 m/s2 peak acceleration, each with the head rotated to the left, then the head rotated to the right in a random order of impact severities. Bilateral electromyograms of the sternocleidomastoids, trapezii, and splenii capitis following impact were measured. Results At a peak acceleration of 13.0 m/s2, with the head rotated to the right, the right trapezius generated 61% of its maximal voluntary contraction electromyogram (MVC EMG, while all other muscles generated 31% or less of this variable (31% for the left trapezius, 13% for the right spleinus. capitis, and 16% for the left splenius capitis. The sternocleidomastoids muscles also tended to show an asymmetric EMG response, with the left sternocleidomastoid (the one responsible for head rotation to the right generating a higher percentage (26% of its MVC EMG than the left sternocleidomastoid (4% (p Conclusion The EMG response to a right anterolateral impact is highly dependent on the head position. The sternocleidomastoid responsible for the direction of head rotation and the trapezius ipsilateral to the direction of head rotation generate the most EMG activity.

  19. Can arthroscopic rotator cuff repair prevent proximal migration of the humeral head?

    Directory of Open Access Journals (Sweden)

    Pablo Sanz-Ruiz

    2015-12-01

    Full Text Available Introduction: Shoulder arthroscopy has become increasingly used in recent years, especially in rotator cuff repair. The purpose of this study was to determine whether arthroscopic rotator cuff repair could prevent proximal migration of the humeral head. Material and Methods: We performed a retrospective study of 56 patients suffering from shoulder pain. They were divided into two groups, one comprising patients with impingement syndrome who underwent acromioplasty only and another comprising patients with rotator cuff tear who underwent acromioplasty combined with rotator cuff repair. The pre-operative Hirooka angle and the results of the simple shoulder test (SST were compared after 1 year. Results: We found no differences between the groups for the Hirooka angle or SST results. We did find a significant difference (P<0.05 between pre-operative and post-operative SST results. Conclusions: Rotator cuff repair using arthroscopy is a minimally invasive procedure that improves function and prevents proximal migration of the humeral head after 1 year of follow-up. [Arch Clin Exp Surg 2015; 4(4.000: 190-195

  20. Episodic vertigo resulting from vascular risk factors, cervical spondylosis and head rotation: Two case reports.

    Science.gov (United States)

    Owolabi, Mayowa O; Ogah, Okechukwu S; Ogunniyi, Adesola

    2007-01-01

    Vascular risk factors predispose to vertebrobasilar ischemia. Cervical osteophytes can impinge on the vertebral artery causing mechanical occlusion during head turning. Presentation with vertigo in such instances is a common finding. A patient with obesity, hyperlipidemia, hypertension, cervical spondylosis, and vertigo triggered by head rotation is presented. She responded to antihypertensive and lipid-lowering drugs, vestibular sedative and application of cervical collar. The second patient also exhibited similar features and responded to conservative treatment. Rotational vertebral artery occlusion resulting from cervical spondylosis in the presence of atherosclerosed collateral vessels is a cause of posterior circulation insufficiency manifesting as vertigo. The tetrad of vertigo resulting from vascular risk factors, cervical spondylosis, and head rotation is proposed for further research.

  1. Rotation and direction judgment from visual images head-slaved in two and three degrees-of-freedom.

    Science.gov (United States)

    Adelstein, B D; Ellis, S R

    2000-03-01

    The contribution to spatial awareness of adding a roll degree-of-freedom (DOF) to telepresence camera platform yaw and pitch was examined in an experiment where subjects judged direction and rotation of stationary target markers in a remote scene. Subjects viewed the scene via head-slaved camera images in a head-mounted display. Elimination of the roll DOF affected rotation judgment, but only at extreme yaw and pitch combinations, and did not affect azimuth and elevation judgement. Systematic azimuth overshoot occurred regardless of roll condition. Observed rotation misjudgments are explained by kinematic models for eye-head direction of gaze.

  2. Predicting superdeformed rotational band-head spin in A ∼ 190 mass region using variable moment of inertia model

    International Nuclear Information System (INIS)

    Uma, V.S.; Goel, Alpana; Yadav, Archana; Jain, A.K.

    2016-01-01

    The band-head spin (I 0 ) of superdeformed (SD) rotational bands in A ∼ 190 mass region is predicted using the variable moment of inertia (VMI) model for 66 SD rotational bands. The superdeformed rotational bands exhibited considerably good rotational property and rigid behaviour. The transition energies were dependent on the prescribed band-head spins. The ratio of transition energies over spin Eγ/ 2 I (RTEOS) vs. angular momentum (I) have confirmed the rigid behaviour, provided the band-head spin value is assigned correctly. There is a good agreement between the calculated and the observed transition energies. This method gives a very comprehensive interpretation for spin assignment of SD rotational bands which could help in designing future experiments for SD bands. (author)

  3. Vertical eye position-dependence of the human vestibuloocular reflex during passive and active yaw head rotations.

    Science.gov (United States)

    Thurtell, M J; Black, R A; Halmagyi, G M; Curthoys, I S; Aw, S T

    1999-05-01

    Vertical eye position-dependence of the human vestibuloocular reflex during passive and active yaw head rotations. The effect of vertical eye-in-head position on the compensatory eye rotation response to passive and active high acceleration yaw head rotations was examined in eight normal human subjects. The stimuli consisted of brief, low amplitude (15-25 degrees ), high acceleration (4,000-6,000 degrees /s2) yaw head rotations with respect to the trunk (peak velocity was 150-350 degrees /s). Eye and head rotations were recorded in three-dimensional space using the magnetic search coil technique. The input-output kinematics of the three-dimensional vestibuloocular reflex (VOR) were assessed by finding the difference between the inverted eye velocity vector and the head velocity vector (both referenced to a head-fixed coordinate system) as a time series. During passive head impulses, the head and eye velocity axes aligned well with each other for the first 47 ms after the onset of the stimulus, regardless of vertical eye-in-head position. After the initial 47-ms period, the degree of alignment of the eye and head velocity axes was modulated by vertical eye-in-head position. When fixation was on a target 20 degrees up, the eye and head velocity axes remained well aligned with each other. However, when fixation was on targets at 0 and 20 degrees down, the eye velocity axis tilted forward relative to the head velocity axis. During active head impulses, the axis tilt became apparent within 5 ms of the onset of the stimulus. When fixation was on a target at 0 degrees, the velocity axes remained well aligned with each other. When fixation was on a target 20 degrees up, the eye velocity axis tilted backward, when fixation was on a target 20 degrees down, the eye velocity axis tilted forward. The findings show that the VOR compensates very well for head motion in the early part of the response to unpredictable high acceleration stimuli-the eye position- dependence of the

  4. Robotic real-time translational and rotational head motion correction during frameless stereotactic radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Xinmin; Belcher, Andrew H.; Grelewicz, Zachary; Wiersma, Rodney D., E-mail: rwiersma@uchicago.edu [Department of Radiation and Cellular Oncology, The University of Chicago, Chicago, Illinois 60637 (United States)

    2015-06-15

    Purpose: To develop a control system to correct both translational and rotational head motion deviations in real-time during frameless stereotactic radiosurgery (SRS). Methods: A novel feedback control with a feed-forward algorithm was utilized to correct for the coupling of translation and rotation present in serial kinematic robotic systems. Input parameters for the algorithm include the real-time 6DOF target position, the frame pitch pivot point to target distance constant, and the translational and angular Linac beam off (gating) tolerance constants for patient safety. Testing of the algorithm was done using a 4D (XY Z + pitch) robotic stage, an infrared head position sensing unit and a control computer. The measured head position signal was processed and a resulting command was sent to the interface of a four-axis motor controller, through which four stepper motors were driven to perform motion compensation. Results: The control of the translation of a brain target was decoupled with the control of the rotation. For a phantom study, the corrected position was within a translational displacement of 0.35 mm and a pitch displacement of 0.15° 100% of the time. For a volunteer study, the corrected position was within displacements of 0.4 mm and 0.2° over 98.5% of the time, while it was 10.7% without correction. Conclusions: The authors report a control design approach for both translational and rotational head motion correction. The experiments demonstrated that control performance of the 4D robotic stage meets the submillimeter and subdegree accuracy required by SRS.

  5. Robotic real-time translational and rotational head motion correction during frameless stereotactic radiosurgery

    International Nuclear Information System (INIS)

    Liu, Xinmin; Belcher, Andrew H.; Grelewicz, Zachary; Wiersma, Rodney D.

    2015-01-01

    Purpose: To develop a control system to correct both translational and rotational head motion deviations in real-time during frameless stereotactic radiosurgery (SRS). Methods: A novel feedback control with a feed-forward algorithm was utilized to correct for the coupling of translation and rotation present in serial kinematic robotic systems. Input parameters for the algorithm include the real-time 6DOF target position, the frame pitch pivot point to target distance constant, and the translational and angular Linac beam off (gating) tolerance constants for patient safety. Testing of the algorithm was done using a 4D (XY Z + pitch) robotic stage, an infrared head position sensing unit and a control computer. The measured head position signal was processed and a resulting command was sent to the interface of a four-axis motor controller, through which four stepper motors were driven to perform motion compensation. Results: The control of the translation of a brain target was decoupled with the control of the rotation. For a phantom study, the corrected position was within a translational displacement of 0.35 mm and a pitch displacement of 0.15° 100% of the time. For a volunteer study, the corrected position was within displacements of 0.4 mm and 0.2° over 98.5% of the time, while it was 10.7% without correction. Conclusions: The authors report a control design approach for both translational and rotational head motion correction. The experiments demonstrated that control performance of the 4D robotic stage meets the submillimeter and subdegree accuracy required by SRS

  6. Effects of humeral head compression taping on the isokinetic strength of the shoulder external rotator muscle in patients with rotator cuff tendinitis

    OpenAIRE

    Kim, Moon-Hwan; Oh, Jae-Seop

    2015-01-01

    [Purpose] The purpose of this study was to examine the effects of humeral head compression taping (HHCT) on the strength of the shoulder external rotator muscle in patients with rotator cuff tendinitis. [Subjects and Methods] Twenty patients with rotator cuff tendinitis were recruited. The shoulder external rotator strength was measured using a Biodex isokinetic dynamometer system. A paired t-test was performed to evaluate within-group differences in the strength of the shoulder external rota...

  7. Effects of humeral head compression taping on the isokinetic strength of the shoulder external rotator muscle in patients with rotator cuff tendinitis.

    Science.gov (United States)

    Kim, Moon-Hwan; Oh, Jae-Seop

    2015-01-01

    [Purpose] The purpose of this study was to examine the effects of humeral head compression taping (HHCT) on the strength of the shoulder external rotator muscle in patients with rotator cuff tendinitis. [Subjects and Methods] Twenty patients with rotator cuff tendinitis were recruited. The shoulder external rotator strength was measured using a Biodex isokinetic dynamometer system. A paired t-test was performed to evaluate within-group differences in the strength of the shoulder external rotator muscle. [Results] Significantly higher shoulder external rotator peak torque and peak torque per body weight were found in the HHCT condition than in the no-taping condition. [Conclusion] HHCT may effectively increase the shoulder external rotator muscle strength in patients with rotator cuff tendinitis.

  8. Amplified Head Rotation in Virtual Reality and the Effects on 3D Search, Training Transfer, and Spatial Orientation.

    Science.gov (United States)

    Ragan, Eric D; Scerbo, Siroberto; Bacim, Felipe; Bowman, Doug A

    2017-08-01

    Many types of virtual reality (VR) systems allow users to use natural, physical head movements to view a 3D environment. In some situations, such as when using systems that lack a fully surrounding display or when opting for convenient low-effort interaction, view control can be enabled through a combination of physical and virtual turns to view the environment, but the reduced realism could potentially interfere with the ability to maintain spatial orientation. One solution to this problem is to amplify head rotations such that smaller physical turns are mapped to larger virtual turns, allowing trainees to view the entire surrounding environment with small head movements. This solution is attractive because it allows semi-natural physical view control rather than requiring complete physical rotations or a fully-surrounding display. However, the effects of amplified head rotations on spatial orientation and many practical tasks are not well understood. In this paper, we present an experiment that evaluates the influence of amplified head rotation on 3D search, spatial orientation, and cybersickness. In the study, we varied the amount of amplification and also varied the type of display used (head-mounted display or surround-screen CAVE) for the VR search task. By evaluating participants first with amplification and then without, we were also able to study training transfer effects. The findings demonstrate the feasibility of using amplified head rotation to view 360 degrees of virtual space, but noticeable problems were identified when using high amplification with a head-mounted display. In addition, participants were able to more easily maintain a sense of spatial orientation when using the CAVE version of the application, which suggests that visibility of the user's body and awareness of the CAVE's physical environment may have contributed to the ability to use the amplification technique while keeping track of orientation.

  9. Vestibuloocular reflex dynamics during high-frequency and high-acceleration rotations of the head on body in rhesus monkey.

    Science.gov (United States)

    Huterer, Marko; Cullen, Kathleen E

    2002-07-01

    For frequencies >10 Hz, the vestibuloocular reflex (VOR) has been primarily investigated during passive rotations of the head on the body in humans. These prior studies suggest that eye movements lag head movements, as predicted by a 7-ms delay in the VOR reflex pathways. However, Minor and colleagues recently applied whole-body rotations of frequencies unity (1.1 at 5 Hz vs. 1.2 at 25 Hz), and phase lag increased only slightly with frequency (from 2 degrees at 5 Hz to 11 degrees at 25 Hz, a marked contrast to the 63 degrees lag at 25 Hz predicted by a 7-ms VOR latency). Furthermore, VOR response dynamics were comparable in darkness and when viewing a target and did not vary with peak velocity. Although monkeys offered less resistance to the initial cycles of applied head motion, the gain and phase of the VOR did not vary for early versus late cycles, suggesting that an efference copy of the motor command to the neck musculature did not alter VOR response dynamics. In addition, VOR dynamics were also probed by applying transient head perturbations with much greater accelerations (peak acceleration >15,000 degrees /s(2)) than have been previously employed. The VOR latency was between 5 and 6 ms, and mean gain was close to unity for two of the three animals tested. A simple linear model well described the VOR responses elicited by sinusoidal and transient head on body rotations. We conclude that the VOR is compensatory over a wide frequency range in monkeys and has similar response dynamics during passive rotation of the head on body as during passive rotation of the whole body in space.

  10. Adaptation of the vertical vestibulo-ocular reflex in cats during low-frequency vertical rotation.

    Science.gov (United States)

    Fushiki, Hiroaki; Maruyama, Motoyoshi; Shojaku, Hideo

    2018-04-01

    We examined plastic changes in the vestibulo-ocular reflex (VOR) during low-frequency vertical head rotation, a condition under which otolith inputs from the vestibular system are essential for VOR generation. For adaptive conditioning of the vertical VOR, 0.02Hz sinusoidal pitch rotation for one hour about the earth's horizontal axis was synchronized with out-of-phase vertical visual stimulation from a random dot pattern. A vertical VOR was well evoked when the upright animal rotated around the earth-horizontal axis (EHA) at low frequency due to the changing gravity stimulus and dynamic stimulation of the otoliths. After adaptive conditioning, the amplitude of the vertical VOR increased by an average of 32.1%. Our observations showing plasticity in the otolithic contribution to the VOR may provide a new strategy for visual-vestibular mismatch training in patients with otolithic disorders. This low-frequency vertical head rotation protocol also provides a model for investigating the mechanisms underlying the adaptation of VORs mediated by otolith activation. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Test of Magnetic Rotation near the band head in ^197,198Pb

    Science.gov (United States)

    Krücken, R.; Clark, R. M.; Deleplanque, M. A.; Diamond, R. M.; Fallon, P.; Macchiavelli, A. O.; Lee, I. Y.; Schmid, G. J.; Stephens, F. S.; Vetter, K.; Dewald, A.; Peusquens, R.; von Brentano, P.; Baldsiefen, G.; Chmel, S.; Hübel, H.; Becker, J. A.; Bernstein, L. A.; Hauschild, K.

    1998-04-01

    The concept of magnetic rotation is tested near the band head of shears-bands in ^197,198Pb by means of a lifetime experiment with the recoil distance method (RDM). The experiment was performed using the Gammasphere array in conjunction with the Cologne Plunger. The B(M1) values extracted from the measured lifetimes can prove the applicability of the concept of magnetic rotation for the states near the band head of these shears bands. The RDM results are compared with tilted axis cranking and shell model calculations. Furthermore the results will be used to test earlier DSAM lifetime measurements for states at higher spins. Preliminary results of this topic will be presented. This work is supported by DOE grant numbers DE-AC03-76SF00098 (LBNL), DE-FG02-91ER40609 (Yale), W-7405-ENG-48 (LLNL) and by the German BMBF for Cologne (No. 06 OK 668) and Bonn.

  12. The cortical spatiotemporal correlate of otolith stimulation: Vestibular evoked potentials by body translations.

    Science.gov (United States)

    Ertl, M; Moser, M; Boegle, R; Conrad, J; Zu Eulenburg, P; Dieterich, M

    2017-07-15

    The vestibular organ senses linear and rotational acceleration of the head during active and passive motion. These signals are necessary for bipedal locomotion, navigation, the coordination of eye and head movements in 3D space. The temporal dynamics of vestibular processing in cortical structures have hardly been studied in humans, let alone with natural stimulation. The aim was to investigate the cortical vestibular network related to natural otolith stimulation using a hexapod motion platform. We conducted two experiments, 1. to estimate the sources of the vestibular evoked potentials (VestEPs) by means of distributed source localization (n=49), and 2. to reveal modulations of the VestEPs through the underlying acceleration intensity (n=24). For both experiments subjects were accelerated along the main axis (left/right, up/down, fore/aft) while the EEG was recorded. We were able to identify five VestEPs (P1, N1, P2, N2, P3) with latencies between 38 and 461 ms as well as an evoked beta-band response peaking with a latency of 68 ms in all subjects and for all acceleration directions. Source localization gave the cingulate sulcus visual (CSv) area and the opercular-insular region as the main origin of the evoked potentials. No lateralization effects due to handedness could be observed. In the second experiment, area CSv was shown to be integral in the processing of acceleration intensities as sensed by the otolith organs, hinting at its potential role in ego-motion detection. These robust VestEPs could be used to investigate the mechanisms of inter-regional interaction in the natural context of vestibular processing and multisensory integration. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. The effect of radial head implant shape on radiocapitellar kinematics during in vitro forearm rotation.

    Science.gov (United States)

    Shannon, Hannah L; Deluce, Simon R; Giles, Joshua W; Johnson, James A; King, Graham J W

    2015-02-01

    A number of radial head implants are in clinical use for the management of radial head fractures and their sequelae. However, the optimal shape of a radial head implant to ensure proper tracking relative to the capitellum has not been established. This in vitro biomechanical study compared radiocapitellar joint kinematics for 3 radial head implant designs as well as the native head. Eight cadaveric upper extremities were tested using a forearm rotation simulator with the elbow at 90° of flexion. Motion of the radius relative to the capitellum was optically tracked. A stem was navigated into a predetermined location and cemented in place. Three unipolar implant shapes were tested: axisymmetric, reverse-engineered patient-specific, and population-based quasi-anatomic. The patient-specific and quasi-anatomic implants were derived from measurements performed on computed tomography models. Medial-lateral and anterior-posterior translation of the radial head with respect to the capitellum varied with forearm rotation and radial head condition. A significant difference in medial-lateral (P = .03) and anterior-posterior (P = .03) translation was found between the native radial head and the 3 implants. No differences were observed among the radial head conditions except for a difference in medial-lateral translation between the axisymmetric and patient-specific implants (P = .04). Radiocapitellar kinematics of the tested radial head implants were similar in all but one comparison, and all had different kinematics from the native radial head. Patient-specific radial head implants did not prove advantageous relative to conventional implant designs. The shape of the fixed stem unipolar radial head implants had little influence on radiocapitellar kinematics when optimally positioned in this testing model. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  14. Self-motion perception and vestibulo-ocular reflex during whole body yaw rotation in standing subjects: the role of head position and neck proprioception.

    Science.gov (United States)

    Panichi, Roberto; Botti, Fabio Massimo; Ferraresi, Aldo; Faralli, Mario; Kyriakareli, Artemis; Schieppati, Marco; Pettorossi, Vito Enrico

    2011-04-01

    Self-motion perception and vestibulo-ocular reflex (VOR) were studied during whole body yaw rotation in the dark at different static head positions. Rotations consisted of four cycles of symmetric sinusoidal and asymmetric oscillations. Self-motion perception was evaluated by measuring the ability of subjects to manually track a static remembered target. VOR was recorded separately and the slow phase eye position (SPEP) was computed. Three different head static yaw deviations (active and passive) relative to the trunk (0°, 45° to right and 45° to left) were examined. Active head deviations had a significant effect during asymmetric oscillation: the movement perception was enhanced when the head was kept turned toward the side of body rotation and decreased in the opposite direction. Conversely, passive head deviations had no effect on movement perception. Further, vibration (100 Hz) of the neck muscles splenius capitis and sternocleidomastoideus remarkably influenced perceived rotation during asymmetric oscillation. On the other hand, SPEP of VOR was modulated by active head deviation, but was not influenced by neck muscle vibration. Through its effects on motion perception and reflex gain, head position improved gaze stability and enhanced self-motion perception in the direction of the head deviation. Copyright © 2010 Elsevier B.V. All rights reserved.

  15. Evaluation of instability after transtrochanteric anterior rotational osteotomy for nontraumatic osteonecrosis of the femoral head

    International Nuclear Information System (INIS)

    Hiranuma, Yasunari; Atsumi, Takashi; Kajiwara, Toshihisa; Tamaoki, Satoshi; Asakura, Yasuhiro

    2009-01-01

    Transtrochanteric anterior rotational osteotomy results in improvement of joint congruity and prevention of progressive collapse and osteoarthritic changes in patients with femoral head osteonecrosis. However, this procedure remains controversial for patients with extensive collapse due to potential osteoarthritis caused by postoperative instability. The purpose of this study was to evaluate hip instability after osteotomy and determine the relation between instability and radiological and clinical outcomes. In all, 27 hips of 24 patients that were followed up for a mean period of 3.8 years were included. Instability was defined as more than 1 mm translation of the femoral head in transverse computed tomography scans obtained at 0 deg and 45 deg flexion of the hip joint. Hips were divided into instability and stability groups. Eleven hips (40%) developed instability after surgery. Osteophytes on the femoral head in 10 hips of the instability group and 2 hips of the stability group had increased in size at follow-up. There was a significant relation between postoperative instability and osteophyte formation. Joint space narrowing was not seen in any of the cases. There was no significant difference between the groups in either the postoperative intact ratio of the femoral head or the Japanese Orthopaedic Association hip score. Neither instability nor osteophyte formation on the femoral head after transtrochanteric anterior rotational osteotomy correlated with progressive osteoarthritic changes or clinical outcome in the presence of an adequate femoral head intact ratio facing the weight-bearing area. (author)

  16. Episodic vertigo resulting from vascular risk factors, cervical spondylosis and head rotation: Two case reports

    OpenAIRE

    Owolabi, Mayowa O; Ogah, Okechukwu S; Ogunniyi, Adesola

    2007-01-01

    Background Vascular risk factors predispose to vertebrobasilar ischemia. Cervical osteophytes can impinge on the vertebral artery causing mechanical occlusion during head turning. Presentation with vertigo in such instances is a common finding. Case presentation A patient with obesity, hyperlipidemia, hypertension, cervical spondylosis, and vertigo triggered by head rotation is presented. She responded to antihypertensive and lipid-lowering drugs, vestibular sedative and application of cervic...

  17. Rotational motion in nuclei

    International Nuclear Information System (INIS)

    Bohr, A.

    1977-01-01

    History is surveyed of the development of the theory of rotational states in nuclei. The situation in the 40's when ideas formed of the collective states of a nucleus is evoked. The general rotation theory and the relation between the single-particle and rotational motion are briefly discussed. Future prospects of the rotation theory development are indicated. (I.W.)

  18. Spin, quadrupole moment, and deformation of the magnetic-rotational band head in Pb193

    Science.gov (United States)

    Balabanski, D. L.; Ionescu-Bujor, M.; Iordachescu, A.; Bazzacco, D.; Brandolini, F.; Bucurescu, D.; Chmel, S.; Danchev, M.; de Poli, M.; Georgiev, G.; Haas, H.; Hübel, H.; Marginean, N.; Menegazzo, R.; Neyens, G.; Pavan, P.; Rossi Alvarez, C.; Ur, C. A.; Vyvey, K.; Frauendorf, S.

    2011-01-01

    The spectroscopic quadrupole moment of the T1/2=9.4(5) ns isomer in Pb193 at an excitation energy Eex=(2585+x) keV is measured by the time-differential perturbed angular distribution method as |Qs|=2.6(3) e b. Spin and parity Iπ=27/2- are assigned to it based on angular distribution measurements. This state is the band head of a magnetic-rotational band, described by the 1i13/2 subshell with the (3s1/2-21h9/21i13/2)11- proton excitation. The pairing-plus-quadrupole tilted-axis cranking calculations reproduce the measured quadrupole moment with a moderate oblate deformation ɛ2=-0.11, similar to that of the 11-proton intruder states, which nuclei in the region. This is the first direct measurement of a quadrupole moment and thus of the deformation of a magnetic-rotational band head.

  19. Effects of sewage sludge on the yield of plants in the rotation system of wheat-white head cabbage-tomato

    Directory of Open Access Journals (Sweden)

    Mehmet Arif Özyazıcı

    2013-01-01

    Full Text Available This research was carried to determine the effects of sewage sludge applications on the yield and yield components of plants under crop rotation system. The field experiments were conducted in the Bafra Plain, located in the north region of Turkey. In this research, the “wheat-white head cabbage-tomato” crop rotation systems have been examined and the same crop rotation has been repeated in two separate years and field trials have been established. Seven treatments were compared: a control without application of sludge nor nitrogen fertilization, a treatment without sludge, but nitrogen and phosphorus fertilization, applied at before sowing of wheat and five treatments where, respectively 10, 20, 30, 40 and 50 tons sludge ha-1. The experimental design was a randomized complete block with three replications. The results showed that all the yield components of wheat and yield of white head cabbage and tomato increased significantly with increasing rates of sewage sludge as compared to control. As a result, 20 t ha-1 of sewage sludge application could be recommended the suitable dose for the rotation of wheat-white head cabbage-tomato in soil and climatic conditions of Bafra Plain.

  20. Measurement and Finite Element Model Validation of Immature Porcine Brain-Skull Displacement during Rapid Sagittal Head Rotations.

    Science.gov (United States)

    Pasquesi, Stephanie A; Margulies, Susan S

    2018-01-01

    Computational models are valuable tools for studying tissue-level mechanisms of traumatic brain injury, but to produce more accurate estimates of tissue deformation, these models must be validated against experimental data. In this study, we present in situ measurements of brain-skull displacement in the neonatal piglet head ( n  = 3) at the sagittal midline during six rapid non-impact rotations (two rotations per specimen) with peak angular velocities averaging 51.7 ± 1.4 rad/s. Marks on the sagittally cut brain and skull/rigid potting surfaces were tracked, and peak values of relative brain-skull displacement were extracted and found to be significantly less than values extracted from a previous axial plane model. In a finite element model of the sagittally transected neonatal porcine head, the brain-skull boundary condition was matched to the measured physical experiment data. Despite smaller sagittal plane displacements at the brain-skull boundary, the corresponding finite element boundary condition optimized for sagittal plane rotations is far less stiff than its axial counterpart, likely due to the prominent role of the boundary geometry in restricting interface movement. Finally, bridging veins were included in the finite element model. Varying the bridging vein mechanical behavior over a previously reported range had no influence on the brain-skull boundary displacements. This direction-specific sagittal plane boundary condition can be employed in finite element models of rapid sagittal head rotations.

  1. Measurement and Finite Element Model Validation of Immature Porcine Brain–Skull Displacement during Rapid Sagittal Head Rotations

    Science.gov (United States)

    Pasquesi, Stephanie A.; Margulies, Susan S.

    2018-01-01

    Computational models are valuable tools for studying tissue-level mechanisms of traumatic brain injury, but to produce more accurate estimates of tissue deformation, these models must be validated against experimental data. In this study, we present in situ measurements of brain–skull displacement in the neonatal piglet head (n = 3) at the sagittal midline during six rapid non-impact rotations (two rotations per specimen) with peak angular velocities averaging 51.7 ± 1.4 rad/s. Marks on the sagittally cut brain and skull/rigid potting surfaces were tracked, and peak values of relative brain–skull displacement were extracted and found to be significantly less than values extracted from a previous axial plane model. In a finite element model of the sagittally transected neonatal porcine head, the brain–skull boundary condition was matched to the measured physical experiment data. Despite smaller sagittal plane displacements at the brain–skull boundary, the corresponding finite element boundary condition optimized for sagittal plane rotations is far less stiff than its axial counterpart, likely due to the prominent role of the boundary geometry in restricting interface movement. Finally, bridging veins were included in the finite element model. Varying the bridging vein mechanical behavior over a previously reported range had no influence on the brain–skull boundary displacements. This direction-specific sagittal plane boundary condition can be employed in finite element models of rapid sagittal head rotations. PMID:29515995

  2. Effect of glass-forming biopreservatives on head group rotational dynamics in freeze-dried phospholipid bilayers: A 31P NMR study

    Science.gov (United States)

    Jain, P.; Sen, S.; Risbud, S. H.

    2009-07-01

    P31 NMR spectroscopy has been used to elucidate the role of glass-forming sugars in the preservation of dipalmitoylphosphatidylcholine (DPPC) lipid bilayers. P31 wideline NMR spectra of freeze-dried pure DPPC, DPPC/trehalose, DPPC/glucose, and DPPC/hydroxyethyl starch (HES) mixtures collected in the temperature range of 25-80 °C have been simulated to obtain quantitative information about rotational dynamics and orientation of the lipid head groups in these media. In the case of pure DPPC, DPPC/glucose, and DPPC/HES, the gel-to-liquid crystalline phase transition of DPPC bilayer is characterized by a sudden increase in the rate of rotational diffusion of the PO4 head groups near 40 °C. The corresponding rotational jump frequency increases from a few kilohertz in the gel phase to at least several megahertz in the liquid crystalline phase. On the other hand, in the case of DPPC/trehalose mixture the temperature of this onset of rapid head group dynamics is increased by ˜10 °C. Trehalose reduces the lipid head group motions most effectively in the temperature range of T ≤50 °C relevant for biopreservation. Additionally, and possibly more importantly, trehalose is found to strongly restrict any change in the orientation of the diffusion axis of the PO4 head groups during the phase transformation. This unique ability of trehalose to maintain the dynamical and orientational rigidity of lipid head groups is likely to be responsible for its superior ability in biopreservation.

  3. The horizontal and vertical cervico-ocular reflexes of the rabbit.

    Science.gov (United States)

    Barmack, N H; Nastos, M A; Pettorossi, V E

    1981-11-16

    Horizontal and vertical cervico-ocular reflexes of the rabbit (HCOR, VCOR) were evoked by sinusoidal oscillation of the body about the vertical and longitudinal axes while the head was fixed. These reflexes were studied over a frequency range of 0.005-0.800 Hz and at stimulus amplitudes of +/- 10 degrees. When the body of the rabbit was rotated horizontally clockwise around the fixed head, clockwise conjugate eye movements were evoked. When the body was rotated about the longitudinal axis onto the right side, the right eye rotated down and the left eye rotated up. The mean gain of the HCOR (eye velocity/body velocity) rose from 0.21 and 0.005 Hz to 0.27 at 0.020 Hz and then declined to 0.06 at 0.3Hz. The gain of the VCOR was less than the gain of the HCOR by a factor of 2-3. The HCOR was measured separately and in combination with the horizontal vestibulo-ocular reflex (HVOR). These reflexes combine linearly. The relative movements of the first 3 cervical vertebrae during stimulation of the HCOR and VCOR were measured. For the HCOR, the largest angular displacement (74%) occurs between C1 and C2. For the VCOR, the largest relative angular displacement (45%) occurs between C2 and C3. Step horizontal clockwise rotation of the head and body (HVOR) evoked low velocity counterclockwise eye movements followed by fast clockwise (resetting) eye movements. Step horizontal clockwise rotation of the body about the fixed head (HCOR) evoked low velocity clockwise eye movements which were followed by fast clockwise eye movements. Step horizontal clockwise rotation of the head about the fixed body (HCOR + HVOR) evoked low velocity counterclockwise eye movements which were not interrupted by fast clockwise eye movements. These data provide further evidence for a linear combination of independent HCOR and HVOR signals.

  4. SU-E-J-195: Quantification of Rotations and Deformations in Head and Heck Radiotherapy

    International Nuclear Information System (INIS)

    Kim, J; Liu, C; Kumarasiri, A; Gordon, J; Siddiqui, F; Chetty, I J; Chetvertkov, M

    2014-01-01

    Purpose: To quantify the magnitude of patient rotations and deformations over the course of head and neck radiotherapy. Methods: 45 CBCT images acquired weekly were selected retrospectively from 5 head and neck cancer patients. CBCT images were registered to the corresponding planning CT images using translation, rigid-body, and cubic B-spline deformable transformations. Elastix ( elastix.isi.uu.nl ), an open-source public domain registration algorithm, was used for all registrations with mutual information as similarity metric and gradient descent as optimization. Four-level multiresolution approach was employed with 2 cm B-spline grid spacing at the finest resolution. Registration qualities were visually verified. Rotational occurrences were quantified from the rigid-body registrations. The magnitude of deformations in planning target volumes (PTV) and organs were quantified from the deformation vector fields with rigid registrations as baseline. Results: The measured rotations (mean±std) were 1.0±1.0 deg, - 0.3±1.0 deg, and 0.1±0.8 deg in the sagittal, coronal, and axial plains respectively. The estimated magnitudes of deformations (mean±std) were 3.4±2.1 mm for PTVs, 2.9±1.2 mm for parotid glands, 2.8±1.2 mm for mandible, and 2.2±1.1 mm for spinal cord. The overall deformation in the body contour was 4.3±4.3 mm. The organ spatial deviation due to rotation was small and approximately 8.4% of that from deformations. Results varied among patients. Conclusion: Rotations occurred about 1.0 deg (1SD) in the H'N area. Daily geometric deviation of target volumes was considerable and mainly from tissue deformation than rotations. Proper safety margin is necessary for adequate target coverage. Online plan adaptation may mitigate the daily differences between the plan and actual patient poses. Partially supported by a grant from Varian Medical Systems, Palo Alto, CA

  5. SU-E-J-195: Quantification of Rotations and Deformations in Head and Heck Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Kim, J; Liu, C; Kumarasiri, A; Gordon, J; Siddiqui, F; Chetty, I J [Henry Ford Health System, Detroit, MI (United States); Chetvertkov, M [Wayne State University, Detroit, MI (United States)

    2014-06-01

    Purpose: To quantify the magnitude of patient rotations and deformations over the course of head and neck radiotherapy. Methods: 45 CBCT images acquired weekly were selected retrospectively from 5 head and neck cancer patients. CBCT images were registered to the corresponding planning CT images using translation, rigid-body, and cubic B-spline deformable transformations. Elastix ( elastix.isi.uu.nl ), an open-source public domain registration algorithm, was used for all registrations with mutual information as similarity metric and gradient descent as optimization. Four-level multiresolution approach was employed with 2 cm B-spline grid spacing at the finest resolution. Registration qualities were visually verified. Rotational occurrences were quantified from the rigid-body registrations. The magnitude of deformations in planning target volumes (PTV) and organs were quantified from the deformation vector fields with rigid registrations as baseline. Results: The measured rotations (mean±std) were 1.0±1.0 deg, - 0.3±1.0 deg, and 0.1±0.8 deg in the sagittal, coronal, and axial plains respectively. The estimated magnitudes of deformations (mean±std) were 3.4±2.1 mm for PTVs, 2.9±1.2 mm for parotid glands, 2.8±1.2 mm for mandible, and 2.2±1.1 mm for spinal cord. The overall deformation in the body contour was 4.3±4.3 mm. The organ spatial deviation due to rotation was small and approximately 8.4% of that from deformations. Results varied among patients. Conclusion: Rotations occurred about 1.0 deg (1SD) in the H'N area. Daily geometric deviation of target volumes was considerable and mainly from tissue deformation than rotations. Proper safety margin is necessary for adequate target coverage. Online plan adaptation may mitigate the daily differences between the plan and actual patient poses. Partially supported by a grant from Varian Medical Systems, Palo Alto, CA.

  6. Spin, quadrupole moment, and deformation of the magnetic-rotational band head in (193)Pb

    CERN Document Server

    Balabanski, D L; Iordachescu, A; Bazzacco, D; Brandolini, F; Bucurescu, D; Chmel, S; Danchev, M; De Poli, M; Georgiev, G; Haas, H; Hubel, H; Marginean, N; Menegazzo, R; Neyens, G; Pavan, P; Rossi Alvarez, C; Ur, C A; Vyvey, K; Frauendorf, S

    2011-01-01

    The spectroscopic quadrupole moment of the T(1/2) = 9.4(5) ns isomer in (193)Pb at an excitation energy E(ex) = (2585 + x) keV is measured by the time-differential perturbed angular distribution method as vertical bar Q(s)vertical bar = 2.6(3) e b. Spin and parity I(pi) = 27/2(-) are assigned to it based on angular distribution measurements. This state is the band head of a magnetic-rotational band, described by the coupling of a neutron hole in the 1i(13/2) subshell with the (3s(1/2)(-2)1h(9/2)1i(13/2))(11-) proton excitation. The pairing-plus-quadrupole tilted-axis cranking calculations reproduce the measured quadrupole moment with a moderate oblate deformation epsilon(2) = -0.11, similar to that of the 11(-)proton intruder states, which occur in the even-even Pb nuclei in the region. This is the first direct measurement of a quadrupole moment and thus of the deformation of a magnetic-rotational band head.

  7. Unilateral otolith centrifugation by head tilt.

    Science.gov (United States)

    Winters, Stephanie M; Bos, Jelte E; Klis, Sjaak F L

    2014-01-01

    To test for otolith asymmetries, several studies described horizontal translation of the body and head en bloc during fast vertical axis rotation. This stimulus causes one otolithic organ to rotate on-axis, and the other to experience centripetal acceleration. To test a new, more simple method of unilateral stimulation with head tilt and the body remaining on axis. During stationary and during 360 deg/s rotation, 12 healthy blindfolded subjects had their heads tilted 30 degrees sideways, positioning one otolithic organ on the axis of rotation after the other. The haptic subjective vertical (SV) was recorded several times by means of a manually adjustable rod. It was found that during stationary the SV tilted about 4 degrees on average in the direction of the head. During rotation, the SV tilted about 9 degrees on average. We therefore estimate the effect of eccentric otolith rotation to be 5 degrees on average. Tilt of the subjective vertical induced by head tilt during on-axis body rotation can provide a relatively uncomplicated alternative to test unilateral otolithic function as compared to body and head translation during rotation. Moreover, unlike eccentric rotation of the entire body, somatosensory cues are minimized by keeping the body fixed on axis and by subtracting the effect of head tilt per se.

  8. Humeral head cysts and rotator cuff tears: an MR arthrographic study

    Energy Technology Data Exchange (ETDEWEB)

    Williams, Martin [Southmead Hospital, Department of Radiology, Westbury-on-Trym, Bristol (United Kingdom); Lambert, Robert G.W.; Jhangri, Gian S.; Grace, Michael; Zelaso, Jay; Wong, Ben; Dhillon, Sukhvinder S. [University of Alberta Hospital, Department of Radiology and Diagnostic Imaging, Edmonton (Canada)

    2006-12-15

    Humeral tuberosity cysts are a common finding, with previous reports suggesting they are related to rotator cuff tear or aging. The aim of this study was to investigate the characteristics of cysts in the tuberosities of the humeral head and their relationship with rotator cuff tear and age. Shoulder MR arthrograms were reviewed in 120 consecutive patients - 83 males (mean age 38.0, range 19-59 years) and 37 females (mean age 41.2, range 15-59 years). Patients were referred for investigation of a variety of conditions, and instability was suspected in only a minority of cases. MR was performed before and after direct arthrography with 0.01% solution of gadolinium. Cysts were defined as well-demarcated circular/ovoid foci in two planes that demonstrated high signal on pre-arthrographic T2W sequences. Location, size and numbers of cysts and post-arthrographic enhancement were documented, along with the location of rotator cuff tears, if present. Cysts in the tuberosities of the humerus were identified in 84 patients (70%), and were seen seven times more frequently in the posterior aspect of the greater tuberosity than anteriorly. Most cysts (94%) demonstrated communication with the joint post-arthrogram. Rotator cuff tears were present in 36 patients, and 79% of all tears occurred in supraspinatus tendon. There was no significant difference in the occurrence of cysts between patients older or younger than age 40 or between genders, but rotator cuff tears were seen significantly more often in the older age group (p<0.01). Tuberosity cysts and rotator cuff tears did not appear to be related (p=0.55). However, whilst this lack of association was quite obvious posteriorly (p=0.84), the trend in the anterior aspect of the greater tuberosity is not as clear (p=0.14). Humeral cysts are most often located in the posterior aspect of the greater tuberosity, communicate with the joint space and, in this location, are not related to aging or rotator cuff tear. (orig.)

  9. Humeral head cysts and rotator cuff tears: an MR arthrographic study

    International Nuclear Information System (INIS)

    Williams, Martin; Lambert, Robert G.W.; Jhangri, Gian S.; Grace, Michael; Zelaso, Jay; Wong, Ben; Dhillon, Sukhvinder S.

    2006-01-01

    Humeral tuberosity cysts are a common finding, with previous reports suggesting they are related to rotator cuff tear or aging. The aim of this study was to investigate the characteristics of cysts in the tuberosities of the humeral head and their relationship with rotator cuff tear and age. Shoulder MR arthrograms were reviewed in 120 consecutive patients - 83 males (mean age 38.0, range 19-59 years) and 37 females (mean age 41.2, range 15-59 years). Patients were referred for investigation of a variety of conditions, and instability was suspected in only a minority of cases. MR was performed before and after direct arthrography with 0.01% solution of gadolinium. Cysts were defined as well-demarcated circular/ovoid foci in two planes that demonstrated high signal on pre-arthrographic T2W sequences. Location, size and numbers of cysts and post-arthrographic enhancement were documented, along with the location of rotator cuff tears, if present. Cysts in the tuberosities of the humerus were identified in 84 patients (70%), and were seen seven times more frequently in the posterior aspect of the greater tuberosity than anteriorly. Most cysts (94%) demonstrated communication with the joint post-arthrogram. Rotator cuff tears were present in 36 patients, and 79% of all tears occurred in supraspinatus tendon. There was no significant difference in the occurrence of cysts between patients older or younger than age 40 or between genders, but rotator cuff tears were seen significantly more often in the older age group (p<0.01). Tuberosity cysts and rotator cuff tears did not appear to be related (p=0.55). However, whilst this lack of association was quite obvious posteriorly (p=0.84), the trend in the anterior aspect of the greater tuberosity is not as clear (p=0.14). Humeral cysts are most often located in the posterior aspect of the greater tuberosity, communicate with the joint space and, in this location, are not related to aging or rotator cuff tear. (orig.)

  10. Kinematics of the AM-50 heading machine cutting head

    Energy Technology Data Exchange (ETDEWEB)

    Sikora, W; Bak, K; Klich, R [Politechnika Slaska, Gliwice (Poland). Instytut Mechanizacji Gornictwa

    1987-01-01

    Analyzes motion of the cutter head of the AM-50 heading machine. Two types of head motion are comparatively evaluated: planar motion and spatial motion. The spatial motion consists of the head rotational motion and horizontal or vertical feed motion, while planar motion consists of rotational motion and vertical feed motion. Equations that describe head motion under conditions of cutter vertical or horizontal feed motion are derived. The angle between the cutting speed direction and working speed direction is defined. On the basis of these formulae variations of cutting speed depending on the cutting tool position on a cutter head are calculated. Calculations made for 2 extreme cutting tools show that the cutting speed ranges from 1,205 m/s to 3,512 m/s. 4 refs.

  11. Medial Entorhinal Grid Cells and Head Direction Cells Rotate with a T-Maze More Often During Less Recently Experienced Rotations

    Science.gov (United States)

    Gupta, Kishan; Beer, Nathan J.; Keller, Lauren A.; Hasselmo, Michael E.

    2014-01-01

    Prior studies of head direction (HD) cells indicate strong landmark control over the preferred firing direction of these cells, with few studies exhibiting shifts away from local reference frames over time. We recorded spiking activity of grid and HD cells in the medial entorhinal cortex of rats, testing correlations of local environmental cues with the spatial tuning curves of these cells' firing fields as animals performed continuous spatial alternation on a T-maze that shared the boundaries of an open-field arena. The environment was rotated into configurations the animal had either seen or not seen in the past recording week. Tuning curves of both cell types demonstrated commensurate shifts of tuning with T-maze rotations during less recent rotations, more so than recent rotations. This strongly suggests that animals are shifting their reference frame away from the local environmental cues over time, learning to use a different reference frame more likely reliant on distal or idiothetic cues. In addition, grid fields demonstrated varying levels of “fragmentation” on the T-maze. The propensity for fragmentation does not depend on grid spacing and grid score, nor animal trajectory, indicating the cognitive treatment of environmental subcompartments is likely driven by task demands. PMID:23382518

  12. [Recognition of the spatially transformed objects in men and women: an analysis of the behavior and evoked potentials].

    Science.gov (United States)

    Slavutskaia, A V; Gerasimenko, N Iu; Mikhaĭlova, E S

    2012-01-01

    In 16 men and 15 women analyzed the accuracy, reaction time and visual evoked potentials during the recognition of familiar objects at different levels of spatial transformation. We used the three levels of transformation: in a fixed position relative to each other details were carried out (1) the displacement of all the details in the radial direction and (2 and 3) a similar shift in conjunction with the rotation of all the details of the figure by +/- 0-45 and +/- 45-90 degrees. The task performance was not dependent on gender: the transformation of the image led to a deterioration of identification with the most identification impairment in the case of maximal details' rotation. Changes in evoked potentials (ERP) are different for men and women. Only in men early (100 ms after stimulus) response of the parietal cortex associated with the level of figure transformation: the more rotation evoked the higher the response. In women figure transformation evoked the ERP changes in the time window of negativity N170, they are associated with figure ungrouping but not with details rotation, and are localized in other visual areas--occipital and temporal. The data obtained are discussed in light of theory of gender specificity of the visual representations of space.

  13. Is the rotation of the femural head a potential initiation for cutting out? A theoretical and experimental approach

    LENUS (Irish Health Repository)

    Lenich, Andreas

    2011-04-22

    Abstract Background Since cut-out still remains one of the major clinical challenges in the field of osteoporotic proximal femur fractures, remarkable developments have been made in improving treatment concepts. However, the mechanics of these complications have not been fully understood. We hypothesize using the experimental data and a theoretical model that a previous rotation of the femoral head due to de-central implant positioning can initiate a cut-out. Methods In this investigation we analysed our experimental data using two common screws (DHS\\/Gamma 3) and helical blades (PFN A\\/TFN) for the fixation of femur fractures in a simple theoretical model applying typical gait pattern on de-central positioned implants. In previous tests during a forced implant rotation by a biomechanical testing machine in a human femoral head the two screws showed failure symptoms (2-6Nm) at the same magnitude as torques acting in the hip during daily activities with de-central implant positioning, while the helical blades showed a better stability (10-20Nm). To calculate the torque of the head around the implant only the force and the leverarm is needed (N [Nm] = F [N] * × [m]). The force F is a product of the mass M [kg] multiplied by the acceleration g [m\\/s2]. The leverarm is the distance between the center of the head of femur and the implant center on a horizontal line. Results Using 50% of 75 kg body weight a torque of 0.37Nm for the 1 mm decentralized position and 1.1Nm for the 3 mm decentralized position of the implant was calculated. At 250% BW, appropriate to a normal step, torques of 1.8Nm (1 mm) and 5.5Nm (3 mm) have been calculated. Comparing of the experimental and theoretical results shows that both screws fail in the same magnitude as torques occur in a more than 3 mm de-central positioned implant. Conclusion We conclude the center-center position in the head of femur of any kind of lag screw or blade is to be achieved to minimize rotation of the femoral head

  14. Is the rotation of the femoral head a potential initiation for cutting out? A theoretical and experimental approach.

    Science.gov (United States)

    Lenich, Andreas; Bachmeier, Samuel; Prantl, Lukas; Nerlich, Michael; Hammer, Jochen; Mayr, Edgar; Al-Munajjed, Amir Andreas; Füchtmeier, Bernd

    2011-04-22

    Since cut-out still remains one of the major clinical challenges in the field of osteoporotic proximal femur fractures, remarkable developments have been made in improving treatment concepts. However, the mechanics of these complications have not been fully understood.We hypothesize using the experimental data and a theoretical model that a previous rotation of the femoral head due to de-central implant positioning can initiate a cut-out. In this investigation we analysed our experimental data using two common screws (DHS/Gamma 3) and helical blades (PFN A/TFN) for the fixation of femur fractures in a simple theoretical model applying typical gait pattern on de-central positioned implants. In previous tests during a forced implant rotation by a biomechanical testing machine in a human femoral head the two screws showed failure symptoms (2-6Nm) at the same magnitude as torques acting in the hip during daily activities with de-central implant positioning, while the helical blades showed a better stability (10-20Nm).To calculate the torque of the head around the implant only the force and the leverarm is needed (N [Nm] = F [N] * × [m]). The force F is a product of the mass M [kg] multiplied by the acceleration g [m/s2]. The leverarm is the distance between the center of the head of femur and the implant center on a horizontal line. Using 50% of 75 kg body weight a torque of 0.37Nm for the 1 mm decentralized position and 1.1Nm for the 3 mm decentralized position of the implant was calculated. At 250% BW, appropriate to a normal step, torques of 1.8Nm (1 mm) and 5.5Nm (3 mm) have been calculated.Comparing of the experimental and theoretical results shows that both screws fail in the same magnitude as torques occur in a more than 3 mm de-central positioned implant. We conclude the center-center position in the head of femur of any kind of lag screw or blade is to be achieved to minimize rotation of the femoral head and to prevent further mechanical complications.

  15. HEAD MOVEMENT DURING WALKING IN THE CAT

    Science.gov (United States)

    ZUBAIR, HUMZA N.; BELOOZEROVA, IRINA N.; SUN, HAI; MARLINSKI, VLADIMIR

    2016-01-01

    Knowledge of how the head moves during locomotion is essential for understanding how locomotion is controlled by sensory systems of the head. We have analyzed head movements of the cat walking along a straight flat pathway in the darkness and light. We found that cats' head left-right translations, and roll and yaw rotations oscillated once per stride, while fore-aft and vertical translations, and pitch rotations oscillated twice. The head reached its highest vertical positions during second half of each forelimb swing, following maxima of the shoulder/trunk by 20–90°. Nose-up rotation followed head upward translation by another 40–90° delay. The peak-to-peak amplitude of vertical translation was ~1.5 cm and amplitude of pitch rotation was ~3°. Amplitudes of lateral translation and roll rotation were ~1 cm and 1.5–3°, respectively. Overall, cats' heads were neutral in roll and 10–30° nose-down, maintaining horizontal semicircular canals and utriculi within 10° of the earth horizontal. The head longitudinal velocity was 0.5–1 m/s, maximal upward and downward linear velocities were ~0.05 and ~0.1 m/s, respectively, and maximal lateral velocity was ~0.05 m/s. Maximal velocities of head pitch rotation were 20–50 °/s. During walking in light, cats stood 0.3–0.5 cm taller and held their head 0.5–2 cm higher than in darkness. Forward acceleration was 25–100% higher and peak-to-peak amplitude of head pitch oscillations was ~20 °/s larger. We concluded that, during walking, the head of the cat is held actively. Reflexes appear to play only a partial role in determining head movement, and vision might further diminish their role. PMID:27339731

  16. A new scale measuring translation of the humeral head as a prognostic factor for the treatment of large and massive rotator cuff tears.

    Science.gov (United States)

    Taniguchi, Noboru; D'Lima, Darryl D; Suenaga, Naoki; Chosa, Etsuo

    2018-02-01

    Failure rates after rotator cuff repair remain high in patients with massive tears. Although superior translation of the humeral head has been used to assess the severity of rotator cuff tears, the relevance of anterior migration of the humeral head to clinical outcomes has not been established. The purpose of this study was to investigate the potential role of the T-scale, a measure of the anterolateral translation of the humeral head, as a prognostic factor for rotator cuff repair. One hundred twenty consecutive patients with full-thickness rotator cuff tears underwent primary rotator cuff repair. The T-scale and acromiohumeral interval (AHI) were measured preoperatively on axial computed tomography scans and radiographs, respectively. The correlations of the T-scale and AHI with previously published scores and active forward elevation (FE) were investigated. The outcome of rotator cuff repairs was compared between patients with positive and patients with negative preoperative T-scale values. The preoperative T-scale but not AHI correlated significantly with postoperative FE and clinical scores in patients with large to massive tears but not in those with small to medium tears. Postoperative FE and clinical scores were significantly higher in patients with positive T-scale values than in those with negative T-scale values. The relative risk of retear was 2.0 to 7.9 times greater in patients with negative T-scale values. Patients with large to massive tears and negative T-scale values had poorer clinical outcomes and higher retear rates. A negative T-scale value represents a useful prognostic factor for considering reverse shoulder arthroplasty in patients at greater risk of retear after rotator cuff repair. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  17. Transtrochanteric rotational osteotomy for avascular necrosis of the femoral head after unstable slipped capital femoral epiphysis: 10-year clinical results.

    Science.gov (United States)

    Nakashima, Yasuharu; Yamamoto, Takuaki; Fukushi, Jun-Ichi; Motomura, Goro; Hamai, Satoshi; Kohno, Yusuke; Iwamoto, Yukihide

    2016-11-01

    Avascular necrosis of the femoral head (AVN) is the most serious complication after unstable slipped capital femoral epiphysis (SCFE), and is often unsalvageable. We report a minimum 10 years of clinical results for transtrochanteric rotational osteotomy of the femoral head (TRO) for AVN. This study included 7 patients (7 hips) with a mean age at surgery of 13.3 years, and the follow-up period was 15.8 years. All patients had prior treatment via closed reduction and pinning of the unstable SCFE, and showed severely collapsed femoral heads. The direction of rotation was anterior in 3 hips and posterior in 4. The Merle d'Aubigné-Postel score (MDPS) was used for clinical assessment, and joint degeneration was assessed with the Kellgren and Lawrence classification (KL-grade). The spherical intact area of the femoral head was moved to the weight-bearing portion, and subluxation was corrected via rotation combined with intentional varus positioning. The mean MDPS improved from 10.3 points to 15.6 points at 5 years, and it was maintained at 15.0 points by 10 years; 3 hips were excellent, 1 was good, 2 were fair, and 1 showed poor outcomes. No patient experienced re-collapse after TRO or required conversion to hip replacement or arthrodesis. After 10 years, degenerative changes became evident over time, and 2 hips progressed to KL-4 with a decreased MDPS. Although some joint degeneration is inevitable in the long-term, TRO is an effective salvage procedure for treating AVN after unstable SCFE. Copyright © 2016 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.

  18. Rotating preventers

    International Nuclear Information System (INIS)

    Tangedahl, M.J.; Stone, C.R.

    1992-01-01

    This paper reports that recent changes in the oil and gas industry and ongoing developments in horizontal and underbalanced drilling necessitated development of a better rotating head. A new device called the rotating blowout preventer (RBOP) was developed by Seal-Tech. It is designed to replace the conventional rotating control head on top of BOP stacks and allows drilling operations to continue even on live (underbalanced) wells. Its low wear characteristics and high working pressure (1,500 psi) allow drilling rig crews to drill safely in slightly underbalanced conditions or handle severe well control problems during the time required to actuate other BOPs in the stack. Drilling with a RBOP allows wellbores to be completely closed in tat the drill floor rather than open as with conventional BOPs

  19. Interactions of cervico-ocular and vestibulo-ocular fast-phase signals in the control of eye position in rabbits.

    Science.gov (United States)

    Barmack, N H; Errico, P; Ferraresi, A; Pettorossi, V E

    1989-01-01

    1. Eye movements in unanaesthetized rabbits were studied during horizontal neck-proprioceptive stimulation (movement of the body with respect to the fixed head), when this stimulation was given alone and when it was given simultaneously with vestibular stimulation (rotation of the head-body). The effect of neck-proprioceptive stimulation on modifying the anticompensatory fast-phase eye movements (AFPs) evoked by vestibular stimulation was studied with a 'conditioning-test' protocol; the 'conditioning' stimulus was a neck-proprioceptive signal evoked by a step-like change in body position with respect to the head and the 'test' stimulus was a vestibular signal evoked by a step rotation of the head-body. 2. The influence of eye position and direction of slow eye movements on the occurrence of compensatory fast-phase eye movements (CFPs) evoked by neck-proprioceptive stimulation was also examined. 3. The anticompensatory fast phase (AFP) evoked by vestibular stimulation was attenuated by a preceding neck-proprioceptive stimulus which when delivered alone evoked compensatory slow-phase eye movements (CSP) in the same direction as the CSP evoked by vestibular stimulation. Conversely, the vestibularly evoked AFP was potentiated by a neck-proprioceptive stimulus which evoked CSPs opposite to that of vestibularly evoked CSPs. 4. Eccentric initial eye positions increased the probability of occurrence of midline-directed compensatory fast-phase eye movements (CFPs) evoked by appropriate neck-proprioceptive stimulation. 5. The gain of the horizontal cervico-ocular reflex (GHCOR) was measured from the combined changes in eye position resulting from AFPs and CSPs. GHCOR was potentiated during simultaneous vestibular stimulation. This enhancement of GHCOR occurred at neck-proprioceptive stimulus frequencies which, in the absence of conjoint vestibular stimulation, do not evoke CSPs. PMID:2795479

  20. Rotational synkineses of occiput and atlas on lateral inclination

    Energy Technology Data Exchange (ETDEWEB)

    Jirout, J.

    1981-02-01

    An X-ray analysis was performed with regard to the question of synkinetic rotational movements of occiput and atlas on lateral inclination of the head and neck. It was found that the frequent synkinetic rotation of the head from the side of inclination can be taken for a stereotype that is ten times more frequent than the rotation towards the side of inclination. However, it does not represent an essential or indispensable feature of the synkinetic reaction. The associated rotation of the atlas from the side of inclination cannot be looked upon as a normal and constant element of the synkinetic response on lateral inclination, as it does not occur in nearly one-half of cases. Moreover, these studies have shown that the rotational movement between occiput and atlas is possible not only in the final stage of maximum forced rotation of the head, but that it belongs to normal dynamic features of the synkinetic response on lateral inclination of the head and neck.

  1. Rotational synkineses of occiput and atlas on lateral inclination

    International Nuclear Information System (INIS)

    Jirout, J.

    1981-01-01

    An X-ray analysis was performed with regard to the question of synkinetic rotational movements of occiput and atlas on lateral inclination of the head and neck. It was found that the frequent synkinetic rotation of the head from the side of inclination can be taken for a stereotype that is ten times more frequent than the rotation towards the side of inclination. However, it does not represent an essential or indispensable feature of the synkinetic reaction. The associated rotation of the atlas from the side of inclination cannot be looked upon as a normal and constant element of the synkinetic response on lateral inclination, as it does not occur in nearly one-half of cases. Moreover, these studies have shown that the rotational movement between occiput and atlas is possible not only in the final stage of maximum forced rotation of the head, but that it belongs to normal dynamic features of the synkinetic response on lateral inclination of the head and neck. (orig.)

  2. Postural Effects on the Mental Rotation of Body-Related Pictures: An fMRI Study

    Directory of Open Access Journals (Sweden)

    Fangbing Qu

    2018-05-01

    Full Text Available This study investigated the embodied effects involved in the mental rotation of pictures of body parts (hands and feet. Blood oxygen level-dependent (BOLD signals were collected from 18 healthy volunteers who performed mental rotation tasks of rotated drawings of hands under different arm postures. Congruent drawings of hands (those congruent with left-hand posture evoked stronger activation in the left supplementary motor area (SMA, left precentral gyrus, and left superior parietal lobule (SPL than did incongruent drawings of hands. Congruent drawings of hands (those congruent with right-hand posture evoked significant activation in the left inferior parietal lobule (IPL, right SMA, bilateral middle frontal gyrus (MFG, left inferior frontal gyrus (IFG, and bilateral superior frontal gyrus (SFG compared to that evoked by the incongruent drawings of hands. Similar methodology was implemented with drawings of feet. However, no significant differences in brain activation were observed between congruent and incongruent drawings of feet. This finding suggests that body posture influences body part-related mental rotation in an effector-specific manner. A direct comparison between the medially and laterally rotated drawings revealed activation in the right IPL, left precentral gyrus, bilateral IFG, and bilateral SFG. These results suggest that biomechanical constraints affect the cognitive process of mental rotation.

  3. Abnormal origins of the long head of the biceps tendon can lead to rotator cuff pathology: a report of two cases.

    Science.gov (United States)

    Zhang, Alan L; Gates, Cameron H; Link, Thomas M; Ma, C Benjamin

    2014-11-01

    Previous case reports have highlighted various anomalous origins of the long head of the biceps tendon (LHBT) that do not originate from the superior glenoid labrum or supraglenoid tubercle. Yet, these cases were all reported as incidental findings and were not thought to cause any significant shoulder pathology. We present the magnetic resonance (MR) imaging and clinical treatment of two cases where aberrant intra-articular origins of the long head of the biceps tendon from the anterior edge of the supraspinatus tendon may have contributed to symptomatic rotator cuff pathology. Arthroscopy confirmed MR findings of partial articular-sided supraspinatus lesions in close proximity to the anomalous origins and treatment with tenodesis of the LHBT successfully relieved symptoms. Although rare occurrences with subtle and potentially misleading imaging findings, it is important to be aware of aberrant origins of the LHBT that may contribute to concomitant rotator cuff pathology.

  4. Vection is the main contributor to motion sickness induced by visual yaw rotation: Implications for conflict and eye movement theories.

    Directory of Open Access Journals (Sweden)

    Suzanne A E Nooij

    Full Text Available This study investigated the role of vection (i.e., a visually induced sense of self-motion, optokinetic nystagmus (OKN, and inadvertent head movements in visually induced motion sickness (VIMS, evoked by yaw rotation of the visual surround. These three elements have all been proposed as contributing factors in VIMS, as they can be linked to different motion sickness theories. However, a full understanding of the role of each factor is still lacking because independent manipulation has proven difficult in the past. We adopted an integrative approach to the problem by obtaining measures of potentially relevant parameters in four experimental conditions and subsequently combining them in a linear mixed regression model. To that end, participants were exposed to visual yaw rotation in four separate sessions. Using a full factorial design, the OKN was manipulated by a fixation target (present/absent, and vection strength by introducing a conflict in the motion direction of the central and peripheral field of view (present/absent. In all conditions, head movements were minimized as much as possible. Measured parameters included vection strength, vection variability, OKN slow phase velocity, OKN frequency, the number of inadvertent head movements, and inadvertent head tilt. Results show that VIMS increases with vection strength, but that this relation varies among participants (R2 = 0.48. Regression parameters for vection variability, head and eye movement parameters were not significant. These results may seem to be in line with the Sensory Conflict theory on motion sickness, but we argue that a more detailed definition of the exact nature of the conflict is required to fully appreciate the relationship between vection and VIMS.

  5. Eye position signals modify vestibulo- and cervico-ocular fast phases during passive yaw rotations in humans.

    Science.gov (United States)

    Anastasopoulos, D; Mandellos, D; Kostadima, V; Pettorossi, V E

    2002-08-01

    We studied the amplitude, latency, and probability of occurrence of fast phases (FP) in darkness to unpredictable vestibular and/or cervical yaw stimulation in normal human subjects. The rotational stimuli were smoothed trapezoidal motion transients of 14 degrees amplitude and 1.25 s duration. Eye position before stimulus application (initial eye position, IEP) was introduced as a variable by asking the subjects to fixate a spot appearing either straight ahead or at 7 degrees eccentric positions. The recordings demonstrated that the generation of FP during vestibular stimulation was facilitated when the whole-body rotation was directed opposite the eccentric IEP. Conversely, FP were attenuated if the whole-body rotation was directed toward the eccentric IEP; i.e., the FP attenuated if they were made to further eccentric positions. Cervical stimulation-induced FP were small and variable in direction when IEP was directed straight ahead before stimulus onset. Eccentric IEPs resulted in large FP, the direction of which was essentially independent of the neck-proprioceptive stimulus. They tended to move the eye toward the primary position, both when the trunk motion under the stationary head was directed toward or away from the IEP. FP dependence on IEP was evident also during head-on-trunk rotations. No consistent interaction between vestibularly and cervically induced FP was found. We conclude that extraretinal eye position signals are able to modify vestibularly evoked reflexive FP in darkness, aiming at minimizing excursions of the eyes away from the primary position. However, neck-induced FP do not relate to specific tasks of stabilization or visual search. By keeping the eyes near the primary position, FP may permit flexibility of orienting responses to incoming stimuli. This recentering bias for both vestibularly and cervically generated FP may represent a visuomotor optimizing strategy.

  6. Goniometer head

    International Nuclear Information System (INIS)

    Dzhazairov-Kakhramanov, V.; Berger, V.D.; Kadyrzhanov, K.K.; Zarifov, R.A.

    1994-01-01

    The goniometer head is an electromechanical instrument that performs the independent transfer of a testing sample on three coordinate axes (X, Y, Z) within limits of ±8 mm and independent rotation relative of these directions. The instrument comprises a sample holder, bellows component and three electrometer drives. The sample holder rotates around the axes X and Y, and is installed on the central arm which rotates around axis Z. One characteristic of this instrument is its independence which allows its use in any camera for researches in the field of radiation physics. 2 figs

  7. IMPLEMENTATION OF IMPROVED NETWORK LIFETIME TECHNIQUE FOR WSN USING CLUSTER HEAD ROTATION AND SIMULTANEOUS RECEPTION

    Directory of Open Access Journals (Sweden)

    Arun Vasanaperumal

    2015-11-01

    Full Text Available There are number of potential applications of Wireless Sensor Networks (WSNs like wild habitat monitoring, forest fire detection, military surveillance etc. All these applications are constrained for power from a stand along battery power source. So it becomes of paramount importance to conserve the energy utilized from this power source. A lot of efforts have gone into this area recently and it remains as one of the hot research areas. In order to improve network lifetime and reduce average power consumption, this study proposes a novel cluster head selection algorithm. Clustering is the preferred architecture when the numbers of nodes are larger because it results in considerable power savings for large networks as compared to other ones like tree or star. Since majority of the applications generally involve more than 30 nodes, clustering has gained widespread importance and is most used network architecture. The optimum number of clusters is first selected based on the number of nodes in the network. When the network is in operation the cluster heads in a cluster are rotated periodically based on the proposed cluster head selection algorithm to increase the network lifetime. Throughout the network single-hop communication methodology is assumed. This work will serve as an encouragement for further advances in the low power techniques for implementing Wireless Sensor Networks (WSNs.

  8. Functional Laterality of Task-Evoked Activation in Sensorimotor Cortex of Preterm Infants: An Optimized 3 T fMRI Study Employing a Customized Neonatal Head Coil.

    Science.gov (United States)

    Scheef, Lukas; Nordmeyer-Massner, Jurek A; Smith-Collins, Adam Pr; Müller, Nicole; Stegmann-Woessner, Gaby; Jankowski, Jacob; Gieseke, Jürgen; Born, Mark; Seitz, Hermann; Bartmann, Peter; Schild, Hans H; Pruessmann, Klaas P; Heep, Axel; Boecker, Henning

    2017-01-01

    Functional magnetic resonance imaging (fMRI) in neonates has been introduced as a non-invasive method for studying sensorimotor processing in the developing brain. However, previous neonatal studies have delivered conflicting results regarding localization, lateralization, and directionality of blood oxygenation level dependent (BOLD) responses in sensorimotor cortex (SMC). Amongst the confounding factors in interpreting neonatal fMRI studies include the use of standard adult MR-coils providing insufficient signal to noise, and liberal statistical thresholds, compromising clinical interpretation at the single subject level. Here, we employed a custom-designed neonatal MR-coil adapted and optimized to the head size of a newborn in order to improve robustness, reliability and validity of neonatal sensorimotor fMRI. Thirteen preterm infants with a median gestational age of 26 weeks were scanned at term-corrected age using a prototype 8-channel neonatal head coil at 3T (Achieva, Philips, Best, NL). Sensorimotor stimulation was elicited by passive extension/flexion of the elbow at 1 Hz in a block design. Analysis of temporal signal to noise ratio (tSNR) was performed on the whole brain and the SMC, and was compared to data acquired with an 'adult' 8 channel head coil published previously. Task-evoked activation was determined by single-subject SPM8 analyses, thresholded at p lateralization of SMC activation, as found in children and adults, is already present in the newborn period.

  9. Scent-evoked nostalgia.

    Science.gov (United States)

    Reid, Chelsea A; Green, Jeffrey D; Wildschut, Tim; Sedikides, Constantine

    2015-01-01

    Can scents evoke nostalgia; what might be the psychological implications of such an evocation? Participants sampled 12 scents and rated the extent to which each scent was familiar, arousing and autobiographically relevant, as well as the extent to which each scent elicited nostalgia. Participants who were high (compared to low) in nostalgia proneness reported more scent-evoked nostalgia, and scents elicited greater nostalgia to the extent that they were arousing, familiar and autobiographically relevant. Scent-evoked nostalgia predicted higher levels of positive affect, self-esteem, self-continuity, optimism, social connectedness and meaning in life. In addition, scent-evoked nostalgia was characterised by more positive emotions than either non-nostalgic autobiographical memories or non-nostalgic non-autobiographical memories. Finally, scent-evoked nostalgia predicted in-the-moment feelings of personal (general or object-specific) nostalgia. The findings represent a foray into understanding the triggers and affective signature of scent-evoked nostalgia.

  10. Refueling system with small diameter rotatable plugs

    International Nuclear Information System (INIS)

    Ritz, W.C.

    1987-01-01

    This patent describes a liquid-metal fastbreeder nuclear reactor comprising a reactor pressure vessel and closure head therefor, a reactor core barrel disposed within the reactor vessel and enclosing a reactor core having therein a large number of closely spaced fuel assemblies, and the reactor core barrel and the reactor core having an approximately concentric circular cross-sectional configuration with a geometric center in predetermined location within the reactor vessel. The improved refueling system described here comprises: a large controllably rotatable plug means comprising the substantial portion of the closure head, a reactor upper internals structure mounted from the large rotatable plug means. The large rotatable plug means has an approximately circular configuration which approximates the cross-sectional configuration of the reactor core barrel with a center of rotation positioned a first predetermined distance from the geometric center of the reactor core barrel so that the large rotatable plug means rotates eccentrically with respect to the reactor core barrel; a small controllably rotatable plug means affixed to the large rotatable plug means and rotatable with respect thereto. The small rotatable plug means has a center of rotation which is offset a second predetermined distance from the rotational center of the large rotatable plug means so that the small rotatable plug means rotates eccentrically with respect to the large rotatable plug means

  11. MRI of the rotator interval of the shoulder

    International Nuclear Information System (INIS)

    Lee, J.C.; Guy, S.; Connell, D.; Saifuddin, A.; Lambert, S.

    2007-01-01

    The rotator interval of the shoulder joint is located between the distal edges of the supraspinatus and subscapularis tendons and contains the insertions of the coracohumeral and superior glenohumeral ligaments. These structures form a complex pulley system that stabilizes the long head of the biceps tendon as it enters the bicipital groove of the humeral head. The rotator interval is the site of a variety of pathological processes including biceps tendon lesions, adhesive capsulitis and anterosuperior internal impingement. This article describes the anatomy, function and pathology of the rotator interval using magnetic resonance imaging (MRI)

  12. Occipital lobe lesions result in a displacement of magnetoencephalography visual evoked field dipoles.

    Science.gov (United States)

    Pang, Elizabeth W; Chu, Bill H W; Otsubo, Hiroshi

    2014-10-01

    The pattern-reversal visual evoked potential measured electrically from scalp electrodes is known to be decreased, or absent, in patients with occipital lobe lesions. We questioned whether the measurement and source analysis of the neuromagnetic visual evoked field (VEF) might offer additional information regarding visual cortex relative to the occipital lesion. We retrospectively examined 12 children (6-18 years) with occipital lesions on MRI, who underwent magnetoencephalography and ophthalmology as part of their presurgical assessment. Binocular half-field pattern-reversal VEFs were obtained in a 151-channel whole-head magnetoencephalography. Data were averaged and dipole source analyses were performed for each half-field stimulation. A significant lateral shift (P occipital lesions. Magnetoencephalography may be useful as a screening test of visual function in young patients. We discuss potential explanations for this lateral shift and emphasize the utility of adding the magnetoencephalography pattern-reversal visual evoked field protocol to the neurologic work-up.

  13. Designing safer composite helmets to reduce rotational accelerations during oblique impacts.

    Science.gov (United States)

    Mosleh, Yasmine; Cajka, Martin; Depreitere, Bart; Vander Sloten, Jos; Ivens, Jan

    2018-05-01

    Oblique impact is the most common accident situation that occupants in traffic accidents or athletes in professional sports experience. During oblique impact, the human head is subjected to a combination of linear and rotational accelerations. Rotational movement is known to be responsible for traumatic brain injuries. In this article, composite foam with a column/matrix composite configuration is proposed for head protection applications to replace single-layer uniform foam, to better attenuate rotational movement of the head during oblique impacts. The ability of composite foam in the mitigation of rotational head movement is studied by performing finite element (FE) simulations of oblique impact on flat and helmet shape specimens. The performance of composite foam with respect to parameters such as compliance of the matrix foam and the number, size and cross-sectional shape of the foam columns is explored in detail, and subsequently an optimized structure is proposed. The simulation results show that using composite foam instead of single-layer foam, the rotational acceleration and velocity of the headform can be significantly reduced. The parametric study indicates that using a more compliant matrix foam and by increasing the number of columns in the composite foam configuration, the rotation can be further mitigated. This was confirmed by experimental results. The simulation results were also analyzed based on global head injury criteria such as head injury criterion, rotational injury criterion, brain injury criterion and generalized acceleration model for brain injury threshold which further confirmed the superior performance of composite foam versus single-layer homogeneous expanded polystyrene foam. The findings of simulations give invaluable information for design of protective helmets or, for instance, headliners for the automotive industry.

  14. Role of the trochlear nerve in eye abduction and frontal vision of the red-eared slider turtle (Trachemys scripta elegans).

    Science.gov (United States)

    Dearworth, J R; Ashworth, A L; Kaye, J M; Bednarz, D T; Blaum, J F; Vacca, J M; McNeish, J E; Higgins, K A; Michael, C L; Skrobola, M G; Jones, M S; Ariel, M

    2013-10-15

    Horizontal head rotation evokes significant responses from trochlear motoneurons of turtle that suggests they have a functional role in abduction of the eyes like that in frontal-eyed mammals. The finding is unexpected given that the turtle is generally considered lateral-eyed and assumed to have eye movements instead like that of lateral-eyed mammals, in which innervation of the superior oblique muscle by the trochlear nerve (nIV) produces intorsion, elevation, and adduction (not abduction). Using an isolated turtle head preparation with the brain removed, glass suction electrodes were used to stimulate nIV with trains of current pulses. Eyes were monitored via an infrared camera with the head placed in a gimble to quantify eye rotations and their directions. Stimulations of nIV evoked intorsion, elevation, and abduction. Dissection of the superior oblique muscle identified lines of action and a location of insertion on the eye, which supported kinematics evoked by nIV stimulation. Eye positions in alert behaving turtles with their head extended were compared with that when their heads were retracted in the carapace. When the head was retracted, there was a reduction in interpupillary distance and an increase in binocular overlap. Occlusion of peripheral fields by the carapace forces the turtle to a more frontal-eyed state, perhaps the reason for the action of abduction by the superior oblique muscle. These findings support why trochlear motoneurons in turtle respond in the same way as abducens motoneurons to horizontal rotations, an unusual characteristic of vestibulo-ocular physiology in comparison with other mammalian lateral-eyed species. Copyright © 2013 Wiley Periodicals, Inc.

  15. Applying DTI white matter orientations to finite element head models to examine diffuse TBI under high rotational accelerations.

    LENUS (Irish Health Repository)

    Colgan, Niall C

    2010-12-01

    The in-vivo mechanical response of neural tissue during impact loading of the head is simulated using geometrically accurate finite element (FE) head models. However, current FE models do not account for the anisotropic elastic material behaviour of brain tissue. In soft biological tissue, there is a correlation between internal microscopic structure and macroscopic mechanical properties. Therefore, constitutive equations are important for the numerical analysis of the soft biological tissues. By exploiting diffusion tensor techniques the anisotropic orientation of neural tissue is incorporated into a non-linear viscoelastic material model for brain tissue and implemented in an explicit FE analysis. The viscoelastic material parameters are derived from published data and the viscoelastic model is used to describe the mechanical response of brain tissue. The model is formulated in terms of a large strain viscoelastic framework and considers non-linear viscous deformations in combination with non-linear elastic behaviour. The constitutive model was applied in the University College Dublin brain trauma model (UCDBTM) (i.e. three-dimensional finite element head model) to predict the mechanical response of the intra-cranial contents due to rotational injury.

  16. Characterizing occipital condyle loads under high-speed head rotation.

    Science.gov (United States)

    Pintar, Frank A; Yoganandan, Narayan; Baisden, Jamie

    2005-11-01

    Because of the need to evaluate anthropomorphic test device (ATD) biofidelity under high-head angular accelerations, the purpose of the present investigation was to develop appropriate instrumentation for intact post mortem human subject (PMHS) testing, validate the instrumentation, and obtain information to characterize the response of the head-neck complex under this loading scenario. A series of rigid-arm pendulum, inertially loaded ATD tests was conducted. Head and neck ATD hydraulic piston chin pull tests were conducted. Subsequently, a series of PMHS tests was conducted to derive the response of the human head-neck under high-rate chin loading. Finally, Hybrid III and THOR-NT ATD head-neck systems were evaluated under the same scenario as the PMHS. A parametric analysis for center of gravity (CG) location and accelerometer orientation determined that even small errors (+/- 3 mm or 2 degrees), produced errors in the force and moment calculations by as much as 17 %. If the moment of inertia (MOI) term was varied by 5 %, resulting moment calculations were affected by as much as 8 %. If the 5 % error in MOI was used to compute occipital condyle moments, and results compared to upper load cell derived moments, peaks differed by as much as 24 %. The head CG and mass MOI should be directly measured for each preparation to obtain accurate results. The injury run on each specimen resulted in predominantly C1-C2 separations or partial separations. The 50(th) percentile probability of AIS=2+ neck injury using tensile force was about 2400 N; for AIS=3+ neck injury the 50(th) percentile risk was about 3180 N. When inserting extension moment as the criteria, the 50(th) percentile probability of an AIS=2+ injury was 51 Nm. The AIS=3+ extension moment at the 50(th) percentile probability was 75 Nm. The new THOR-NT ATD head-neck produced more biofidelic responses with an alternate head-neck junction design compared to the Hybrid III ATD.

  17. Neonatal and maternal outcomes of successful manual rotation to correct malposition of the fetal head; A retrospective and prospective observational study.

    Science.gov (United States)

    Tempest, Nicola; McGuinness, Naomi; Lane, Steven; Hapangama, Dharani K

    2017-01-01

    To evaluate the neonatal and maternal outcomes associated with successful operative vaginal births assisted by manual rotation. Prospective and retrospective observational study. Delivery suite in a tertiary referral teaching hospital in England. A cohort of 2,426 consecutive operative births, in the second stage of labour, complicated with malposition of the fetal head during 2006-2013. Outcomes of all births successfully assisted by manual rotation followed by direct traction instruments were compared with other methods of operative birth for fetal malposition in the second stage of labour (rotational ventouse, Kielland forceps and caesarean section). Associated neonatal outcomes (admission to the special care baby unit, low cord pH, low Apgar and shoulder dystocia) and maternal outcomes (massive obstetric haemorrhage (blood loss of >1500ml) and obstetric anal sphincter injury). Births successfully assisted with manual rotation followed by direct traction instruments, resulted in 10% (36/346) of the babies being admitted to the Special Care Baby Unit, 4.9% (17/349) shoulder dystocia, 2% (7/349) massive obstetric haemorrhage and 1.7% (6/349) obstetric anal sphincter injury, similar to other methods of rotational births. Adverse neonatal and maternal outcomes associated with successful manual rotations followed by direct traction instruments were comparable to traditional methods of operative births. There is an urgent need to standardise the practice (guidance, training) and documentation of manual rotation followed by direct traction instrumental deliveries that will enable assessment of its efficacy and the absolute safety in achieving a vaginal birth.

  18. Sex Differences in Anthropometrics and Heading Kinematics Among Division I Soccer Athletes.

    Science.gov (United States)

    Bretzin, Abigail C; Mansell, Jamie L; Tierney, Ryan T; McDevitt, Jane K

    Soccer players head the ball repetitively throughout their careers; this is also a potential mechanism for a concussion. Although not all soccer headers result in a concussion, these subconcussive impacts may impart acceleration, deceleration, and rotational forces on the brain, leaving structural and functional deficits. Stronger neck musculature may reduce head-neck segment kinematics. The relationship between anthropometrics and soccer heading kinematics will not differ between sexes. The relationship between anthropometrics and soccer heading kinematics will not differ between ball speeds. Pilot, cross-sectional design. Level 3. Division I soccer athletes (5 male, 8 female) were assessed for head-neck anthropometric and neck strength measurements in 6 directions (ie, flexion, extension, right and left lateral flexions and rotations). Participants headed the ball 10 times (25 or 40 mph) while wearing an accelerometer secured to their head. Kinematic measurements (ie, linear acceleration and rotational velocity) were recorded at 2 ball speeds. Sex differences were observed in neck girth ( t = 5.09, P soccer heading kinematics for sex and ball speeds. Neck girth and neck strength are factors that may limit head impact kinematics.

  19. The importance of rotational kinematics in pedestrian head to windshield impacts

    NARCIS (Netherlands)

    Mordaka, J.; Kleiven, S.; Schijndel-de Nooij, M. van; Lange, R. de; Casanova, L.J.G.; Carter, E.L.; Holst, H. von

    2007-01-01

    The objective of the present study was to analyze the effect of angular kinematics on head injury in pedestrian head-to-windshield impacts. Three cases of pedestrian head impacts were simulated with FE head and windshield models. The initial impact conditions were obtained from pedestrian accident

  20. Otolith and canal reflexes in human standing

    Science.gov (United States)

    Cathers, Ian; Day, Brian L; Fitzpatrick, Richard C

    2005-01-01

    We used galvanic vestibular stimulation (GVS) to identify human balance reflexes of the semicircular canals and otolith organs. The experiment used a model of vestibular signals arising from GVS modulation of the net signal from vestibular afferents. With the head upright, the model predicts that the GVS-evoked canal signal indicates lateral head rotation while the otolith signal indicates lateral tilt or acceleration. Both signify body sway transverse to the head. With the head bent forward, the model predicts that the canal signal indicates body spin about a vertical axis but the otolith signal still signifies lateral body motion. Thus, we compared electromyograms (EMG) in the leg muscles and body sway evoked by GVS when subjects stood with the head upright or bent forward. With the head upright, GVS evoked a large sway in the direction of the anodal electrode. This response was abolished with the head bent forward leaving only small, oppositely directed, transient responses at the start and end of the stimulus. With the head upright, GVS evoked short-latency (60–70 ms), followed by medium-latency (120 ms) EMG responses, of opposite polarity. Bending the head forward abolished the medium-latency but preserved the short-latency response. This is compatible with GVS evoking separate otolithic and canal reflexes, indicating that balance is controlled by independent canal and otolith reflexes, probably through different pathways. We propose that the short-latency reflex and small transient sway are driven by the otolith organs and the medium-latency response and the large sway are driven by the semicircular canals. PMID:15618274

  1. Unilateral otolith centrifugation by head tilt

    NARCIS (Netherlands)

    Winters, S.M.; Bos, J.E.; Klis, S.F.L.

    2014-01-01

    BACKGROUND: To test for otolith asymmetries, several studies described horizontal translation of the body and head en bloc during fast vertical axis rotation. This stimulus causes one otolithic organ to rotate on-axis, and the other to experience centripetal acceleration. OBJECTIVE: To test a new,

  2. Tendon patch grafting using the long head of the biceps for irreparable massive rotator cuff tears

    International Nuclear Information System (INIS)

    Sano, Hirotaka; Itoi, Eiji; Mineta, Mitsuyoshi; Kita, Atsushi

    2010-01-01

    Surgical treatment of massive rotator cuff tears is challenging for shoulder surgeons. The purpose of this study was to investigate both clinical outcomes and cuff integrity after tendon patch grafting using the long head of the biceps (LHB) tendon for irreparable massive rotator cuff tears. A short deltoid splitting approach was used to expose the torn cuff tendon stump. After tenodesis of the LHB tendon, its intraarticular portion was resected. If the size of the harvested tendon was smaller than that of the cuff defect, it was split into two layers. Then, the LHB tendon was sutured to the remnant cuff tendons and fixed to the footprint using the transosseous suture technique. A total of 14 patients (12 men, 2 women; average age 64 years) underwent this procedure. The average postoperative follow-up period was 28 months (range 12-51 months). Active elevation angle of the shoulder as well as the Japanese Orthopaedic Association (JOA) score were assessed before surgery and at the time of follow-up. Postoperative cuff integrity was assessed using T2-weighted magnetic resonance imaging (MRI). All cuff defects were successfully closed with this technique. Average active elevation angle improved from 69deg to 149deg. Total JOA score also improved from 54.7 points to 83.1 points. Thirteen shoulders showed no re-tearing on T2-weighted MRI; a minor discontinuity of the repaired cuff tendon was observed in the other shoulder. The LHB tendon is available in case tenodesis or tenotomy is needed. The resected tendon may be used as a graft for rotator cuff repair without any additional skin incision, which could reduce both the surgical invasion and the risk of infection. The LHB tendon patch grafting may be one of the useful options for surgical treatment of irreparable massive rotator cuff tears. (author)

  3. Neonatal and maternal outcomes of successful manual rotation to correct malposition of the fetal head; A retrospective and prospective observational study.

    Directory of Open Access Journals (Sweden)

    Nicola Tempest

    Full Text Available To evaluate the neonatal and maternal outcomes associated with successful operative vaginal births assisted by manual rotation.Prospective and retrospective observational study.Delivery suite in a tertiary referral teaching hospital in England.A cohort of 2,426 consecutive operative births, in the second stage of labour, complicated with malposition of the fetal head during 2006-2013.Outcomes of all births successfully assisted by manual rotation followed by direct traction instruments were compared with other methods of operative birth for fetal malposition in the second stage of labour (rotational ventouse, Kielland forceps and caesarean section.Associated neonatal outcomes (admission to the special care baby unit, low cord pH, low Apgar and shoulder dystocia and maternal outcomes (massive obstetric haemorrhage (blood loss of >1500ml and obstetric anal sphincter injury.Births successfully assisted with manual rotation followed by direct traction instruments, resulted in 10% (36/346 of the babies being admitted to the Special Care Baby Unit, 4.9% (17/349 shoulder dystocia, 2% (7/349 massive obstetric haemorrhage and 1.7% (6/349 obstetric anal sphincter injury, similar to other methods of rotational births.Adverse neonatal and maternal outcomes associated with successful manual rotations followed by direct traction instruments were comparable to traditional methods of operative births. There is an urgent need to standardise the practice (guidance, training and documentation of manual rotation followed by direct traction instrumental deliveries that will enable assessment of its efficacy and the absolute safety in achieving a vaginal birth.

  4. Development of an Inflatable Head/Neck Restraint System for Ejection Seats

    Science.gov (United States)

    1977-02-28

    crewman’s head . It has been observed that low pressures, about 2 psi (1.38 nt/cm2 ) to 4 psi (2.76 nt/cm2 ), create some "spring back" or trampoline ...neck ring Neck injury Head rotation 210 ABSTRACT (Continue on rev’erse side If necessary end identify by block number) 4A ringý-shaped inflatable head ...injuries due to violent forward head rotation at the time of ejection thrust and parachute opening shock. Inflation of the neck ring will,’ be conducted by a

  5. The magnitude of translational and rotational head accelerations experienced by riders during downhill mountain biking.

    Science.gov (United States)

    Hurst, Howard T; Atkins, Stephen; Dickinson, Ben D

    2018-03-21

    To determine the magnitude of translational and rotational head accelerations during downhill mountain biking. Observational study. Sixteen male downhill cyclists (age 26.4±8.4years; stature 179.4±7.2cm; mass 75.3±5.9kg) were monitored during two rounds of the British Downhill Series. Riders performed two runs on each course wearing a triaxial accelerometer behind the right ear. The means of the two runs for each course were used to determine differences between courses for mean and maximum peak translational (g) and rotational accelerations (rad/s 2 ) and impact duration for each course. Significant differences (p10g), FW=12.5±7.6, RYF=42.8±27.4 (t (22.96) =-4.70; p<0.001; 95% CI=17.00 to 43.64); maximum peak rotational acceleration, FW=6805.4±3073.8rad/s 2 , RYF=9799.9±3381.7rad/s 2 (t (32) =-2.636; p=0.01; 95% CI=680.31 to 5308.38); mean acceleration duration FW=4.7±1.2ms, RYF=6.5±1.4ms (t (32) =-4.05; p<0.001; 95% CI=0.91 to 2.76) and maximum acceleration duration, FW=11.6±4.5ms, RYF=21.2±9.1 (t (29.51) =-4.06; p=0.001; 95% CI=4.21 to 14.94). No other significant differences were found. Findings indicate that downhill riders may be at risk of sustaining traumatic brain injuries and course design influences the number and magnitude of accelerations. Copyright © 2018 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  6. Hypertrophy of the extra-articular tendon of the long head of biceps correlates with the location and size of a rotator cuff tear.

    Science.gov (United States)

    Takahashi, N; Sugaya, H; Matsuki, K; Miyauchi, H; Matsumoto, M; Tokai, M; Onishi, K; Hoshika, S; Ueda, Y

    2017-06-01

    The aim of this study was to assess hypertrophy of the extra-articular tendon of the long head of biceps (LHB) in patients with a rotator cuff tear. The study involved 638 shoulders in 334 patients (175 men, 159 women, mean age 62.6 years; 25 to 81) with unilateral symptomatic rotator cuff tears. The cross-sectional area (CSA) of the LHB tendon in the bicipital groove was measured pre-operatively in both shoulders using ultrasound. There were 154 asymptomatic rotator cuff tears in the contralateral shoulder. Comparisons were made between those with a symptomatic tear, an asymptomatic tear and those with no rotator cuff tear. In the affected shoulders, the CSAs were compared in relation to the location and size of the rotator cuff tear. The mean CSA was 21.0 mm 2 (4 to 71) in those with a symptomatic rotator cuff tear, 19.9 mm 2 (4 to 75) in those with an asymptomatic rotator cuff tear and 14.1 mm 2 (5 to 43) in those with no rotator cuff tear. The mean CSA in patients with both symptomatic and asymptomatic rotator cuff tears was significantly larger than in those with no rotator cuff tear (p cuff tear and those with an antero-superior cuff tear. Regardless of the symptoms, there was significant hypertrophy of the extra-articular LHB tendon in patients with a rotator cuff tear. The values were significantly related to the size of the tear. Cite this article: Bone Joint J 2017;99-B:806-11. ©2017 The British Editorial Society of Bone & Joint Surgery.

  7. Quantification of vestibular-induced eye movements in zebrafish larvae

    Directory of Open Access Journals (Sweden)

    Mo Weike

    2010-09-01

    Full Text Available Abstract Background Vestibular reflexes coordinate movements or sensory input with changes in body or head position. Vestibular-evoked responses that involve the extraocular muscles include the vestibulo-ocular reflex (VOR, a compensatory eye movement to stabilize retinal images. Although an angular VOR attributable to semicircular canal stimulation was reported to be absent in free-swimming zebrafish larvae, recent studies reveal that vestibular-induced eye movements can be evoked in zebrafish larvae by both static tilts and dynamic rotations that tilt the head with respect to gravity. Results We have determined herein the basis of sensitivity of the larval eye movements with respect to vestibular stimulus, developmental stage, and sensory receptors of the inner ear. For our experiments, video recordings of larvae rotated sinusoidally at 0.25 Hz were analyzed to quantitate eye movements under infrared illumination. We observed a robust response that appeared as early as 72 hours post fertilization (hpf, which increased in amplitude over time. Unlike rotation about an earth horizontal axis, rotation about an earth vertical axis at 0.25 Hz did not evoke eye movements. Moreover, vestibular-induced responses were absent in mutant cdh23 larvae and larvae lacking anterior otoliths. Conclusions Our results provide evidence for a functional vestibulo-oculomotor circuit in 72 hpf zebrafish larvae that relies upon sensory input from anterior/utricular otolith organs.

  8. Vestibular evoked myogenic potentials and video head impulse test in patients with vertigo, dizziness and imbalance.

    Science.gov (United States)

    Skorić, Magdalena Krbot; Adamec, Ivan; Pavičić, Tin; Pavlović, Ivan; Ruška, Berislav; Crnošija, Luka; Habek, Mario

    2017-05-01

    The aim of this study was to compare vestibular evoked myogenic potentials (VEMP) and video head impulse test (vHIT) results in patients presenting with vertigo and dizziness. We retrospectively analyzed data of all patients with the chief complaint of vertigo, dizziness, or imbalance that underwent VEMP and vHIT from January 2015 to January 2016. A total of 117 patients (73 females, mean age 53.92±16.76) fulfilled inclusion criteria: group 1 included patients with the final diagnosis of vestibular neuritis (VN) (N=31 (16 right and 15 left VN)), group 2 included patients with the final diagnosis of vertigo of central origin (N=23) and group 3 included patients with the final diagnosis of unspecified dizziness (N=63). There was significant correlation between oVEMP asymmetry and asymmetry of the lateral canals 60ms gains on vHIT (r=0.225, p=0.026). Significant correlation between oVEMP and vHIT asymmetry was present in VN patients (r=0.749, p<0.001), while no correlation was found in the groups 2 and 3. oVEMP and vHIT lateral canals asymmetries were significantly greater in patients with vestibular neuritis. Furthermore, positive correlations of oVEMP amplitudes with 60ms gain of the lateral semicircular canal and slope of the anterior semicircular canal on vHIT, and cVEMP with slope of the posterior semicircular canal on the vHIT were found. These changes were significantly more pronounced in patients with vestibular neuritis. In conclusion, VEMPs and vHIT data should be used complementarily; asymmetry on both tests strongly supports peripheral vestibular system involvement. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. False-positive head-impulse test in cerebellar ataxia

    Directory of Open Access Journals (Sweden)

    Olympia eKremmyda

    2012-11-01

    Full Text Available Abstract:The objective of this study was to compare the findings of the bedside head impulse test (HIT, passive head rotation gain, and caloric irrigation in patients with cerebellar ataxia (CA. In 16 patients with CA and bilaterally pathological bedside HIT, VOR gains were measured during HIT and passive head rotation by scleral search coil technique. Eight of the patients had pathologically reduced caloric responsiveness, while the other eight had normal caloric responses. Those with normal calorics showed a slightly reduced HIT gain (mean±SD: 0.73±0.15. In those with pathological calorics, gains 80ms and 100 ms after the HIT as well as the passive rotation VOR gains were significantly lower. The corrective saccade after head turn occurred earlier in patients with pathological calorics (111±62 ms after onset of the HIT than in those with normal calorics. (191±17 ms, p=0.0064 We indentified two groups of patients with CA: those with an isolated moderate HIT deficit only, probably due to floccular dysfunction, and those with combined HIT, passive rotation and caloric deficit, probably due to a peripheral vestibular deficit. From a clinical point of view, these results show that the bedside HIT alone can be false positive for establishing a diagnosis of a bilateral peripheral vestibular deficit in patients with CA.

  10. Adverse Weather Evokes Nostalgia.

    Science.gov (United States)

    van Tilburg, Wijnand A P; Sedikides, Constantine; Wildschut, Tim

    2018-03-01

    Four studies examined the link between adverse weather and the palliative role of nostalgia. We proposed and tested that (a) adverse weather evokes nostalgia (Hypothesis 1); (b) adverse weather causes distress, which predicts elevated nostalgia (Hypothesis 2); (c) preventing nostalgia exacerbates weather-induced distress (Hypothesis 3); and (d) weather-evoked nostalgia confers psychological benefits (Hypothesis 4). In Study 1, participants listened to recordings of wind, thunder, rain, and neutral sounds. Adverse weather evoked nostalgia. In Study 2, participants kept a 10-day diary recording weather conditions, distress, and nostalgia. We also obtained meteorological data. Adverse weather perceptions were positively correlated with distress, which predicted higher nostalgia. Also, adverse natural weather was associated with corresponding weather perceptions, which predicted elevated nostalgia. (Results were mixed for rain.) In Study 3, preventing nostalgia (via cognitive load) increased weather-evoked distress. In Study 4, weather-evoked nostalgia was positively associated with psychological benefits. The findings pioneer the relevance of nostalgia as source of comfort in adverse weather.

  11. Mental rotation evoked potentials P500 in patients with major depressive disorder

    Institute of Scientific and Technical Information of China (English)

    陈玖

    2013-01-01

    Objective To explore the difference on mental rotation ability between major depressive disorders and healthy subjects.Methods Twenty-three patients with major depressive disorders and 24 healthy subjects

  12. Effect of different head-neck-jaw postures on cervicocephalic kinesthetic sense.

    Science.gov (United States)

    Zafar, H; Alghadir, A H; Iqbal, Z A

    2017-12-01

    To investigate the effect of different induced head-neck-jaw postures on head-neck relocation error among healthy subjects. 30 healthy adult male subjects participated in this study. Cervicocephalic kinesthetic sense was measured while standing, habitual sitting, habitual sitting with clenched jaw and habitual sitting with forward head posture during right rotation, left rotation, flexion and extension using kinesthetic sensibility test. Head-neck relocation error was least while standing, followed by habitual sitting, habitual sitting with forward head posture and habitual sitting with jaw clenched. However, there was no significant difference in error between different tested postures during all the movements. To the best of our knowledge, this is the first study to see the effect of different induced head-neck-jaw postures on head-neck position sense among healthy subjects. Assuming a posture for a short duration of time doesn't affect head-neck relocation error in normal healthy subjects.

  13. Elbow joint laxity after experimental radial head excision and lateral collateral ligament rupture

    DEFF Research Database (Denmark)

    Jensen, Steen Lund; Olsen, Bo Sanderhoff; Tyrdal, Stein

    2005-01-01

    The objectives of this experimental study were to investigate the effect of radial head excision and lateral collateral ligament (LCL) division on elbow joint laxity and to determine the efficacy of radial head prosthetic replacement and LCL repair. Valgus, varus, internal rotation, and external...... rotation of the ulna were measured during passive flexion-extension and application of a 0.75-Nm torque in 6 intact cadaveric elbows and after (1) either excision of the radial head or division of the LCL, (2) removal of both constraints, (3) isolated radial head prosthetic replacement, (4) isolated LCL...... normalized varus laxity but resulted in a 2.9 degrees increase in external rotatory laxity. The combined procedures restored laxity completely. The radial head is a constraint to varus and external rotation in the elbow joint, functioning by maintaining tension in the LCL. Still, removal of both constraints...

  14. Music evokes vivid autobiographical memories.

    Science.gov (United States)

    Belfi, Amy M; Karlan, Brett; Tranel, Daniel

    2016-08-01

    Music is strongly intertwined with memories-for example, hearing a song from the past can transport you back in time, triggering the sights, sounds, and feelings of a specific event. This association between music and vivid autobiographical memory is intuitively apparent, but the idea that music is intimately tied with memories, seemingly more so than other potent memory cues (e.g., familiar faces), has not been empirically tested. Here, we compared memories evoked by music to those evoked by famous faces, predicting that music-evoked autobiographical memories (MEAMs) would be more vivid. Participants listened to 30 songs, viewed 30 faces, and reported on memories that were evoked. Memories were transcribed and coded for vividness as in Levine, B., Svoboda, E., Hay, J. F., Winocur, G., & Moscovitch, M. [2002. Aging and autobiographical memory: Dissociating episodic from semantic retrieval. Psychology and Aging, 17, 677-689]. In support of our hypothesis, MEAMs were more vivid than autobiographical memories evoked by faces. MEAMs contained a greater proportion of internal details and a greater number of perceptual details, while face-evoked memories contained a greater number of external details. Additionally, we identified sex differences in memory vividness: for both stimulus categories, women retrieved more vivid memories than men. The results show that music not only effectively evokes autobiographical memories, but that these memories are more vivid than those evoked by famous faces.

  15. Head position modulates optokinetic nystagmus.

    Science.gov (United States)

    Pettorossi, V E; Ferraresi, A; Botti, F M; Panichi, R; Barmack, N H

    2011-08-01

    Orientation and movement relies on both visual and vestibular information mapped in separate coordinate systems. Here, we examine how coordinate systems interact to guide eye movements of rabbits. We exposed rabbits to continuous horizontal optokinetic stimulation (HOKS) at 5°/s to evoke horizontal eye movements, while they were statically or dynamically roll-tilted about the longitudinal axis. During monocular or binocular HOKS, when the rabbit was roll-tilted 30° onto the side of the eye stimulated in the posterior → anterior (P → A) direction, slow phase eye velocity (SPEV) increased by 3.5-5°/s. When the rabbit was roll-tilted 30° onto the side of the eye stimulated in the A → P direction, SPEV decreased to ~2.5°/s. We also tested the effect of roll-tilt after prolonged optokinetic stimulation had induced a negative optokinetic afternystagmus (OKAN II). In this condition, the SPEV occurred in the dark, "open loop." Modulation of SPEV of OKAN II depended on the direction of the nystagmus and was consistent with that observed during "closed loop" HOKS. Dynamic roll-tilt influenced SPEV evoked by HOKS in a similar way. The amplitude and the phase of SPEV depended on the frequency of vestibular oscillation and on HOKS velocity. We conclude that the change in the linear acceleration of the gravity vector with respect to the head during roll-tilt modulates the gain of SPEV depending on its direction. This modulation improves gaze stability at different image retinal slip velocities caused by head roll-tilt during centric or eccentric head movement.

  16. Peripheral optogenetic stimulation induces whisker movement and sensory perception in head-fixed mice.

    Science.gov (United States)

    Park, Sunmee; Bandi, Akhil; Lee, Christian R; Margolis, David J

    2016-06-08

    We discovered that optical stimulation of the mystacial pad in Emx1-Cre;Ai27D transgenic mice induces whisker movements due to activation of ChR2 expressed in muscles controlling retraction and protraction. Using high-speed videography in anesthetized mice, we characterize the amplitude of whisker protractions evoked by varying the intensity, duration, and frequency of optogenetic stimulation. Recordings from primary somatosensory cortex (S1) in anesthetized mice indicated that optogenetic whisker pad stimulation evokes robust yet longer latency responses than mechanical whisker stimulation. In head-fixed mice trained to report optogenetic whisker pad stimulation, psychometric curves showed similar dependence on stimulus duration as evoked whisker movements and S1 activity. Furthermore, optogenetic stimulation of S1 in expert mice was sufficient to substitute for peripheral stimulation. We conclude that whisker protractions evoked by optogenetic activation of whisker pad muscles results in cortical activity and sensory perception, consistent with the coding of evoked whisker movements by reafferent sensory input.

  17. A six-week clinical evaluation of the plaque and gingivitis efficacy of an oscillating-rotating power toothbrush with a novel brush head utilizing angled CrissCross bristles versus a sonic toothbrush.

    Science.gov (United States)

    Klukowska, Malgorzata; Grender, Julie M; Conde, Erinn; Goyal, C Ram; Qaqish, J

    2014-01-01

    To compare the efficacy of an oscillating-rotating power toothbrush with a novel brush head incorporating angled CrissCross bristles (Oral-B Triumph with SmartGuide with Oral-B CrossAction brush head) versus a sonic toothbrush (Sonicare DiamondClean) for plaque and gingivitis reduction over a six-week period. This was a single-center, randomized, examiner-blind, two-treatment, parallel group study involving 65 subjects per group. Subjects presenting with mild-to-moderate gingivitis at Baseline were randomly assigned to either the oscillating-rotating brush or the sonic brush. They were instructed to use their assigned toothbrush and a standard fluoride dentifrice for two minutes twice daily at home for six weeks. Gingivitis and plaque were assessed at Baseline and Week 6 using the Modified Gingival Index (MGI), Gingival Bleeding Index (GBI), and Rustogi Modified Navy Plaque Index (RMNPI). Data were analyzed using an Analysis of Covariance (ANCOVA), with baseline as the covariate. Subjects also completed a consumer perception questionnaire to evaluate their brushing experience. One-hundred and thirty subjects were enrolled in the study and randomized to treatment. Sixty-four subjects per group completed the trial. Both brushes produced statistically significant reductions in gingivitis and plaque measures at Week 6 relative to Baseline (p gingivitis and plaque measures compared to the sonic toothbrush. The benefits for the oscillating-rotating brush over the sonic brush were 32.6% for gingivitis, 35.4% for gingival bleeding, 32% for number of bleeding sites, 22% for whole mouth plaque, 24.2% for gingival margin plaque, and 33.3% for approximal plaque (p gingival margin plaque, where p = 0.018). Analysis of the consumer perception questionnaire results showed subjects using the oscillating-rotating brush rated it higher for overall use experience and key attributes related to cleaning, gentleness, and brush head shape/size versus subjects in the sonic brush group

  18. Activation of biceps femoris long head reduces tibiofemoral anterior shear force and tibial internal rotation torque in healthy subjects.

    Science.gov (United States)

    Azmi, Nur Liyana; Ding, Ziyun; Xu, Rui; Bull, Anthony M J

    2018-01-01

    The anterior cruciate ligament (ACL) provides resistance to tibial internal rotation torque and anterior shear at the knee. ACL deficiency results in knee instability. Optimisation of muscle contraction through functional electrical stimulation (FES) offers the prospect of mitigating the destabilising effects of ACL deficiency. The hypothesis of this study is that activation of the biceps femoris long head (BFLH) reduces the tibial internal rotation torque and the anterior shear force at the knee. Gait data of twelve healthy subjects were measured with and without the application of FES and taken as inputs to a computational musculoskeletal model. The model was used to investigate the optimum levels of BFLH activation during FES gait in reducing the anterior shear force to zero. This study found that FES significantly reduced the tibial internal rotation torque at the knee during the stance phase of gait (p = 0.0322) and the computational musculoskeletal modelling revealed that a mean BFLH activation of 20.8% (±8.4%) could reduce the anterior shear force to zero. At the time frame when the anterior shear force was zero, the internal rotation torque was reduced by 0.023 ± 0.0167 Nm/BW, with a mean 188% reduction across subjects (p = 0.0002). In conclusion, activation of the BFLH is able to reduce the tibial internal rotation torque and the anterior shear force at the knee in healthy control subjects. This should be tested on ACL deficient subject to consider its effect in mitigating instability due to ligament deficiency. In future clinical practice, activating the BFLH may be used to protect ACL reconstructions during post-operative rehabilitation, assist with residual instabilities post reconstruction, and reduce the need for ACL reconstruction surgery in some cases.

  19. Environmental and Physiological Factors Affect Football Head Impact Biomechanics.

    Science.gov (United States)

    Mihalik, Jason P; Sumrall, Adam Z; Yeargin, Susan W; Guskiewicz, Kevin M; King, Kevin B; Trulock, Scott C; Shields, Edgar W

    2017-10-01

    Recent anecdotal trends suggest a disproportionate number of head injuries in collegiate football players occur during preseason football camp. In warmer climates, this season also represents the highest risk for heat-related illness among collegiate football players. Because concussion and heat illnesses share many common symptoms, we need 1) to understand if environmental conditions, body temperature, and hydration status affect head impact biomechanics; and 2) to determine if an in-helmet thermistor could provide a valid measure of gastrointestinal temperature. A prospective cohort of 18 Division I college football players (age, 21.1 ± 1.4 yr; height, 187.7 ± 6.6 cm; mass, 114.5 ± 23.4 kg). Data were collected during one control and three experimental sessions. During each session, the Head Impact Telemetry System recorded head impact biomechanics (linear acceleration, rotational acceleration, and severity profile) and in-helmet temperature. A wet bulb globe device recorded environmental conditions, and CorTemp™ Ingestible Core Body Temperature Sensors recorded gastrointestinal temperature. Our findings suggest that linear acceleration (P = 0.57), rotational acceleration (P = 0.16), and Head Impact Technology severity profile (P = 0.33) are not influenced by environmental or physiological conditions. We did not find any single or combination of predictors for impact severity. Rotational acceleration was approaching significance between our early experimental sessions when compared with our control session. More research should be conducted to better understand if rotational accelerations are a component of impact magnitudes that are affected due to changes in environmental conditions, body temperature, and hydration status.

  20. Analysis of relationship among visual evoked potential, oscillatory potential and visual acuity under stimulated weightlessness

    Directory of Open Access Journals (Sweden)

    Jun Zhao

    2013-05-01

    Full Text Available AIM: To observe the influence of head-down tilt simulated weightlessness on visual evoked potential(VEP, oscillatory potentials(OPsand visual acuity, and analyse the relationship among them. METHODS: Head-down tilt for -6° was adopted in 14 healthy volunteers. Distant visual acuity, near visual acuity, VEP and OPs were recorded before, two days and five days after trial. The record procedure of OPs followed the ISCEV standard for full-field clinical electroretinography(2008 update. RESULTS: Significant differences were detected in the amplitude of P100 waves and ∑OPs among various time points(P<0.05. But no relationship was observed among VEP, OPs and visual acuity. CONCLUSION: Head-down tilt simulated weightlessness induce the rearrange of blood of the whole body including eyes, which can make the change of visual electrophysiology but not visual acuity.

  1. Proprioceptive evoked gamma oscillations

    DEFF Research Database (Denmark)

    Arnfred, S.M.; Hansen, Lars Kai; Parnas, J.

    2007-01-01

    A proprioceptive stimulus consisting of a weight change of a handheld load has recently been shown to elicit an evoked potential. Previously, somatosensory gamma oscillations have only been evoked by electrical stimuli. We conjectured that a natural proprioceptive stimulus also would be able...... to evoke gamma oscillations. EEG was recorded using 64 channels in 14 healthy subjects. In each of three runs a stimulus of 100 g load increment in each hand was presented in 120 trials. Data were wavelet transformed and runs collapsed. Inter-trial phase coherence (ITPC) was computed as the best measure...

  2. Investigating the correspondence between driver head position and glance location

    Directory of Open Access Journals (Sweden)

    Joonbum Lee

    2018-02-01

    Full Text Available The relationship between a driver’s glance orientation and corresponding head rotation is highly complex due to its nonlinear dependence on the individual, task, and driving context. This paper presents expanded analytic detail and findings from an effort that explored the ability of head pose to serve as an estimator for driver gaze by connecting head rotation data with manually coded gaze region data using both a statistical analysis approach and a predictive (i.e., machine learning approach. For the latter, classification accuracy increased as visual angles between two glance locations increased. In other words, the greater the shift in gaze, the higher the accuracy of classification. This is an intuitive but important concept that we make explicit through our analysis. The highest accuracy achieved was 83% using the method of Hidden Markov Models (HMM for the binary gaze classification problem of (a glances to the forward roadway versus (b glances to the center stack. Results suggest that although there are individual differences in head-glance correspondence while driving, classifier models based on head-rotation data may be robust to these differences and therefore can serve as reasonable estimators for glance location. The results suggest that driver head pose can be used as a surrogate for eye gaze in several key conditions including the identification of high-eccentricity glances. Inexpensive driver head pose tracking may be a key element in detection systems developed to mitigate driver distraction and inattention.

  3. Lateral head turning affects temporal memory.

    Science.gov (United States)

    Vicario, Carmelo Mario; Martino, Davide; Pavone, Enea Francesco; Fuggetta, Giorgio

    2011-08-01

    Spatial attention is a key factor in the exploration and processing of the surrounding environment, and plays a role in linking magnitudes such as space, time, and numbers. The present work evaluates whether shifting the coordinates of spatial attention through rotational head movements may affect the ability to estimate the duration of different time intervals. A computer-based implicit timing task was employed, in which participants were asked to concentrate and report verbally on colour changes of sequential stimuli displayed on a computer screen; subsequently, they were required to reproduce the temporal duration (ranging between 5 and 80 sec.) of the perceived stimuli using the computer keyboard. There was statistically significant overestimation of the 80-sec. intervals exclusively on the rightward rotation head posture, whereas head posture did not affect timing performances on shorter intervals. These findings support the hypothesis that the coordinates of spatial attention influence the ability to process time, consistent with the existence of common cortical metrics of space and time in healthy humans.

  4. Adaptive Changes in the Perception of Fast and Slow Movement at Different Head Positions.

    Science.gov (United States)

    Panichi, Roberto; Occhigrossi, Chiara; Ferraresi, Aldo; Faralli, Mario; Lucertini, Marco; Pettorossi, Vito E

    2017-05-01

    This paper examines the subjective sense of orientation during asymmetric body rotations in normal subjects. Self-motion perception was investigated in 10 healthy individuals during asymmetric whole-body rotation with different head orientations. Both on-vertical axis and off-vertical axis rotations were employed. Subjects tracked a remembered earth-fixed visual target while rotating in the dark for four cycles of asymmetric rotation (two half-sinusoidal cycles of the same amplitude, but of different duration). The rotations induced a bias in the perception of velocity (more pronounced with fast than with slow motion). At the end of rotation, a marked target position error (TPE) was present. For the on-vertical axis rotations, the TPE was no different if the rotations were performed with a 30° nose-down, a 60° nose-up, or a 90° side-down head tilt. With off-vertical axis rotations, the simultaneous activation of the semicircular canals and otolithic receptors produced a significant increase of TPE for all head positions. This difference between on-vertical and off-vertical axis rotation was probably partly due to the vestibular transfer function and partly due to different adaptation to the speed of rotation. Such a phenomenon might be generated in different components of the vestibular system. The adaptive process enhancing the perception of dynamic movement around the vertical axis is not related to the specific semicircular canals that are activated; the addition of an otolithic component results in a significant increase of the TPE.Panichi R, Occhigrossi C, Ferraresi A, Faralli M, Lucertini M, Pettorossi VE. Adaptive changes in the perception of fast and slow movement at different head positions. Aerosp Med Hum Perform. 2017; 88(5):463-468.

  5. Noise-evoked otoacoustic emissions in humans

    NARCIS (Netherlands)

    Maat, B; Wit, HP; van Dijk, P

    2000-01-01

    Click-evoked otoacoustic emissions (CEOAEs) and acoustical responses evoked by bandlimited Gaussian noise (noise-evoked otoacoustic emissions; NEOAEs) were measured in three normal-hearing subjects. For the NEOAEs the first- and second-order Wiener kernel and polynomial correlation functions up to

  6. Temporal dynamics of ocular position dependence of the initial human vestibulo-ocular reflex.

    Science.gov (United States)

    Crane, Benjamin T; Tian, Junru; Demer, Joseph L

    2006-04-01

    While an ideal vestibulo-ocular reflex (VOR) generates ocular rotations compensatory for head motion, during visually guided movements, Listing's Law (LL) constrains the eye to rotational axes lying in Listing's Plane (LP). The present study was conducted to explore the recent proposal that the VOR's rotational axis is not collinear with the head's, but rather follows a time-dependent strategy intermediate between LL and an ideal VOR. Binocular LPs were defined during visual fixation in eight normal humans. The VOR was evoked by a highly repeatable transient whole-body yaw rotation in darkness at a peak acceleration of 2800 deg/s2. Immediately before rotation, subjects regarded targets 15 or 500 cm distant located at eye level, 20 degrees up, or 20 degrees down. Eye and head responses were compared with LL predictions in the position and velocity domains. LP orientation varied both among subjects and between individual subject's eyes, and rotated temporally with convergence by 5 +/- 5 degrees (+/-SEM). In the position domain, the eye compensated for head displacement even when the head rotated out of LP. Even within the first 20 ms from onset of head rotation, the ocular velocity axis tilted relative to the head axis by 30% +/- 8% of vertical gaze position. Saccades increased this tilt. Regardless of vertical gaze position, the ocular rotation axis tilted backward 4 degrees farther in abduction than in adduction. There was also a binocular vertical eye velocity transient and lateral tilt of the ocular axis. These disconjugate, short-latency axis perturbations appear intrinsic to the VOR and may have neural or mechanical origins.

  7. Rotational IMRT techniques compared to fixed gantry IMRT and Tomotherapy: multi-institutional planning study for head-and-neck cases

    International Nuclear Information System (INIS)

    Wiezorek, Tilo; Schubert, Kai; Wagner, Daniela; Wendt, Thomas G; Brachwitz, Tim; Georg, Dietmar; Blank, Eyck; Fotina, Irina; Habl, Gregor; Kretschmer, Matthias; Lutters, Gerd; Salz, Henning

    2011-01-01

    Recent developments enable to deliver rotational IMRT with standard C-arm gantry based linear accelerators. This upcoming treatment technique was benchmarked in a multi-center treatment planning study against static gantry IMRT and rotational IMRT based on a ring gantry for a complex parotid gland sparing head-and-neck technique. Treatment plans were created for 10 patients with head-and-neck tumours (oropharynx, hypopharynx, larynx) using the following treatment planning systems (TPS) for rotational IMRT: Monaco (ELEKTA VMAT solution), Eclipse (Varian RapidArc solution) and HiArt for the helical tomotherapy (Tomotherapy). Planning of static gantry IMRT was performed with KonRad, Pinnacle and Panther DAO based on step&shoot IMRT delivery and Eclipse for sliding window IMRT. The prescribed doses for the high dose PTVs were 65.1Gy or 60.9Gy and for the low dose PTVs 55.8Gy or 52.5Gy dependend on resection status. Plan evaluation was based on target coverage, conformity and homogeneity, DVHs of OARs and the volume of normal tissue receiving more than 5Gy (V 5Gy ). Additionally, the cumulative monitor units (MUs) and treatment times of the different technologies were compared. All evaluation parameters were averaged over all 10 patients for each technique and planning modality. Depending on IMRT technique and TPS, the mean CI values of all patients ranged from 1.17 to 2.82; and mean HI values varied from 0.05 to 0.10. The mean values of the median doses of the spared parotid were 26.5Gy for RapidArc and 23Gy for VMAT, 14.1Gy for Tomo. For fixed gantry techniques 21Gy was achieved for step&shoot+KonRad, 17.0Gy for step&shoot+Panther DAO, 23.3Gy for step&shoot+Pinnacle and 18.6Gy for sliding window. V 5Gy values were lowest for the sliding window IMRT technique (3499 ccm) and largest for RapidArc (5480 ccm). The lowest mean MU value of 408 was achieved by Panther DAO, compared to 1140 for sliding window IMRT. All IMRT delivery technologies with their associated TPS

  8. A randomized clinical trial evaluating gingivitis and plaque reduction of an oscillating-rotating power brush with a new brush head with angled bristles versus a marketed sonic brush with self-adjusting technology.

    Science.gov (United States)

    Klukowska, Malgorzata; Grender, Julie M; Conde, Erinn; Ccahuana-Vasquez, Renzo Alberto; Ram Goyal, C

    2014-08-01

    To compare the efficacy of an oscillating-rotating power toothbrush with a novel brush head incorporating angled CrissCross bristles (Oral-B Pro 7000 SmartSeries and Oral-B CrossAction brush head) versus a marketed sonic toothbrush (Colgate ProClinical A1500 with the Triple Clean brush head) in the reduction of gingivitis and plaque over a 6-week period. This was a single center, randomized, open label, examiner-blind, 2-treatment, parallel group study. Study participants who met the entrance criteria were enrolled in the study and randomly assigned to one of the two toothbrush groups. Study participants brushed with their assigned toothbrush and a marketed fluoride dentifrice for 2 minutes twice daily at home for 6 weeks. Gingivitis and plaque were evaluated at baseline and Week 6. Gingivitis was assessed using the Modified Gingival Index (MGI) and Gingival Bleeding Index (GBI) and plaque was assessed using the Rustogi Modified Navy Plaque Index (RMNPI). Data was analyzed using the ANCOVA with baseline as the covariate. In total, 130 study participants were randomized to treatment resulting in 64 study participants per group completing the study. Both brushes produced statistically significant (P gingivitis and plaque measures relative to baseline. The oscillating-rotating,brush with the novel brush head demonstrated statistically significantly (P gingivitis measures, as well as whole mouth and interproximal plaque measures, compared to the sonic toothbrush. The benefit for the oscillating- rotating brush over the sonic brush was 21.3% for gingivitis, 35.7% for gingival bleeding, 34.7% for number of bleeding sites, 17.4% for whole mouth plaque, and 21.2% for interproximal plaque. There were no adverse events reported or observed for either brush.

  9. Effect of head pitch and roll orientations on magnetically induced vertigo.

    Science.gov (United States)

    Mian, Omar S; Li, Yan; Antunes, Andre; Glover, Paul M; Day, Brian L

    2016-02-15

    Lying supine in a strong magnetic field, such as in magnetic resonance imaging scanners, can induce a perception of whole-body rotation. The leading hypothesis to explain this invokes a Lorentz force mechanism acting on vestibular endolymph that acts to stimulate semicircular canals. The hypothesis predicts that the perception of whole-body rotation will depend on head orientation in the field. Results showed that the direction and magnitude of apparent whole-body rotation while stationary in a 7 T magnetic field is influenced by head orientation. The data are compatible with the Lorentz force hypothesis of magnetic vestibular stimulation and furthermore demonstrate the operation of a spatial transformation process from head-referenced vestibular signals to Earth-referenced body motion. High strength static magnetic fields are known to induce vertigo, believed to be via stimulation of the vestibular system. The leading hypothesis (Lorentz forces) predicts that the induced vertigo should depend on the orientation of the magnetic field relative to the head. In this study we examined the effect of static head pitch (-80 to +40 deg; 12 participants) and roll (-40 to +40 deg; 11 participants) on qualitative and quantitative aspects of vertigo experienced in the dark by healthy humans when exposed to the static uniform magnetic field inside a 7 T MRI scanner. Three participants were additionally examined at 180 deg pitch and roll orientations. The effect of roll orientation on horizontal and vertical nystagmus was also measured and was found to affect only the vertical component. Vertigo was most discomforting when head pitch was around 60 deg extension and was mildest when it was around 20 deg flexion. Quantitative analysis of vertigo focused on the induced perception of horizontal-plane rotation reported online with the aid of hand-held switches. Head orientation had effects on both the magnitude and the direction of this perceived rotation. The data suggest

  10. Measurement of flow inside a vacuum cleaner head

    Science.gov (United States)

    Iguchi, Ryotaro; Ban, Hisataka; Sakakibara, Jun

    2017-11-01

    Vacuum cleaner head with rotating brushes is widely used as a home appliance. Although it efficiently collects dusts from the floor, flow field of the air and motion of the dust inside the head have not been fully investigated. In this study, we performed 3D-PIV (particle tracking velocimetry) measurement of velocity field inside the head. Water was used as working fluid, which allows a use of fluorescent particle to reduce unwanted reflection from the brushes and inner surface of the head. Mean velocity field and turbulence statistics in the head with and without the brush will be presented.

  11. Effect of slow, small movement on the vibration-evoked kinesthetic illusion.

    Science.gov (United States)

    Cordo, P J; Gurfinkel, V S; Brumagne, S; Flores-Vieira, C

    2005-12-01

    The study reported in this paper investigated how vibration-evoked illusions of joint rotation are influenced by slow (0.3 degrees /s), small (2-4 degrees ) passive rotation of the joint. Normal human adults (n=15) matched the perceived position of the left ("reference") arm with the right ("matching") arm while vibration (50 pps, 0.5 mm) was applied for 30 s to the relaxed triceps brachii of the reference arm. Both arms were constrained to rotate horizontally at the elbow. Three experimental conditions were investigated: (1) vibration of the stationary reference arm, (2) slow, small passive extension or flexion of the reference arm during vibration, and (3) slow, small passive extension or flexion of the reference arm without vibration. Triceps brachii vibration at 50 pps induced an illusion of elbow flexion. The movement illusion began after several seconds, relatively fast to begin with and gradually slowing down to a stop. On average, triceps vibration produced illusory motion at an average latency of 6.3 s, amplitude of 9.7 degrees , velocity of 0.6 degrees /s, and duration of 16.4 s. During vibration, slow, small ( approximately 0.3 degrees /s, 1.3 degrees ) passive rotations of the joint dramatically enhanced, stopped, or reversed the direction of illusory movement, depending on the direction of the passive joint rotation. However, the subjects' perceptions of these passive elbow rotations were exaggerated: 2-3 times the size of the actual movement. In the absence of vibration, the subjects accurately reproduced these passive joint rotations. We discuss whether the exaggerated perception of slow, small movement during vibration is better explained by contributions of non muscle spindle Ia afferents or by changes in the mechanical transmission of vibration to the receptor.

  12. Vision based motion control for a humanoid head

    NARCIS (Netherlands)

    Visser, L.C.; Carloni, Raffaella; Stramigioli, Stefano

    2009-01-01

    This paper describes the design of a motion control algorithm for a humanoid robotic head, which consists of a neck with four degrees of freedom and two eyes (a stereo pair system) that tilt on a common axis and rotate sideways freely. The kinematic and dynamic properties of the head are analyzed

  13. Self-organizing path integration using a linked continuous attractor and competitive network: path integration of head direction.

    Science.gov (United States)

    Stringer, Simon M; Rolls, Edmund T

    2006-12-01

    A key issue is how networks in the brain learn to perform path integration, that is update a represented position using a velocity signal. Using head direction cells as an example, we show that a competitive network could self-organize to learn to respond to combinations of head direction and angular head rotation velocity. These combination cells can then be used to drive a continuous attractor network to the next head direction based on the incoming rotation signal. An associative synaptic modification rule with a short term memory trace enables preceding combination cell activity during training to be associated with the next position in the continuous attractor network. The network accounts for the presence of neurons found in the brain that respond to combinations of head direction and angular head rotation velocity. Analogous networks in the hippocampal system could self-organize to perform path integration of place and spatial view representations.

  14. Development of a Meso-Scale Fiberoptic Rotation Sensor for a Torsion Actuator.

    Science.gov (United States)

    Sheng, Jun; Desai, Jaydev P

    2018-01-01

    This paper presents the development of a meso-scale fiberoptic rotation sensor for a shape memory alloy (SMA) torsion actuator for neurosurgical applications. Within the sensor, a rotary head with a reflecting surface is capable of modulating the light intensity collected by optical fibers when the rotary head is coupled to the torsion actuator. The mechanism of light intensity modulation is modeled, followed by experimental model verification. Meanwhile, working performances for different rotary head designs, optical fibers, and fabrication materials are compared. After the calibration of the fiberoptic rotation sensor, the sensor is capable of precisely measuring rotary motion and controlling the SMA torsion actuator with feedback control.

  15. The Twente humanoid head

    NARCIS (Netherlands)

    Reilink, Rob; Visser, L.C.; Bennik, J.; Carloni, Raffaella; Brouwer, Dannis Michel; Stramigioli, Stefano

    2009-01-01

    This video shows the results of the project on the mechatronic development of the Twente humanoid head. The mechanical structure consists of a neck with four degrees of freedom (DOFs) and two eyes (a stereo pair system) which tilt on a common axis and rotate sideways freely providing a three more

  16. Evoked emotions predict food choice.

    Science.gov (United States)

    Dalenberg, Jelle R; Gutjar, Swetlana; Ter Horst, Gert J; de Graaf, Kees; Renken, Remco J; Jager, Gerry

    2014-01-01

    In the current study we show that non-verbal food-evoked emotion scores significantly improve food choice prediction over merely liking scores. Previous research has shown that liking measures correlate with choice. However, liking is no strong predictor for food choice in real life environments. Therefore, the focus within recent studies shifted towards using emotion-profiling methods that successfully can discriminate between products that are equally liked. However, it is unclear how well scores from emotion-profiling methods predict actual food choice and/or consumption. To test this, we proposed to decompose emotion scores into valence and arousal scores using Principal Component Analysis (PCA) and apply Multinomial Logit Models (MLM) to estimate food choice using liking, valence, and arousal as possible predictors. For this analysis, we used an existing data set comprised of liking and food-evoked emotions scores from 123 participants, who rated 7 unlabeled breakfast drinks. Liking scores were measured using a 100-mm visual analogue scale, while food-evoked emotions were measured using 2 existing emotion-profiling methods: a verbal and a non-verbal method (EsSense Profile and PrEmo, respectively). After 7 days, participants were asked to choose 1 breakfast drink from the experiment to consume during breakfast in a simulated restaurant environment. Cross validation showed that we were able to correctly predict individualized food choice (1 out of 7 products) for over 50% of the participants. This number increased to nearly 80% when looking at the top 2 candidates. Model comparisons showed that evoked emotions better predict food choice than perceived liking alone. However, the strongest predictive strength was achieved by the combination of evoked emotions and liking. Furthermore we showed that non-verbal food-evoked emotion scores more accurately predict food choice than verbal food-evoked emotions scores.

  17. [Rotator cuff tear athropathy prevalence].

    Science.gov (United States)

    Guerra-Soriano, F; Encalada-Díaz, M I; Ruiz-Suárez, M; Valero-González, F S

    2017-01-01

    Glenohumeral arthritis secondary to massive rotator cuff tear presents with a superior displacement and femoralization of the humeral head with coracoacromial arch acetabularization. The purpose of this study was to establish prevalence of rotator cuff tear artropathy (CTA) at our institution. Four hundred electronic records were reviewed from which we identified 136 patients with rotator cuff tears. A second group was composed with patients with massive cuff tears that were analized and staged by the Seebauer cuff tear arthropathy classification. Thirty four patients with massive rotator cuff tears were identified, 8 male and 26 female (age 60.1 ± 10.26 years). Massive rotator cuff tear prevalence was 25%. CTA prevalence found in the rotator cuff group was 19 and 76% in the massive cuff tears group. Patients were staged according to the classification with 32% in stage 1a, 11% 1b, 32% 2a and 0% 2b. CTA prevalence in patients with rotator cuff tears and massive cuff tears is higher than the one reported in American population. We consider that a revision of the Seebauer classification to be appropriate to determine its reliability.

  18. Rotational IMRT techniques compared to fixed gantry IMRT and Tomotherapy: multi-institutional planning study for head-and-neck cases

    Directory of Open Access Journals (Sweden)

    Lutters Gerd

    2011-02-01

    Full Text Available Abstract Background Recent developments enable to deliver rotational IMRT with standard C-arm gantry based linear accelerators. This upcoming treatment technique was benchmarked in a multi-center treatment planning study against static gantry IMRT and rotational IMRT based on a ring gantry for a complex parotid gland sparing head-and-neck technique. Methods Treatment plans were created for 10 patients with head-and-neck tumours (oropharynx, hypopharynx, larynx using the following treatment planning systems (TPS for rotational IMRT: Monaco (ELEKTA VMAT solution, Eclipse (Varian RapidArc solution and HiArt for the helical tomotherapy (Tomotherapy. Planning of static gantry IMRT was performed with KonRad, Pinnacle and Panther DAO based on step&shoot IMRT delivery and Eclipse for sliding window IMRT. The prescribed doses for the high dose PTVs were 65.1Gy or 60.9Gy and for the low dose PTVs 55.8Gy or 52.5Gy dependend on resection status. Plan evaluation was based on target coverage, conformity and homogeneity, DVHs of OARs and the volume of normal tissue receiving more than 5Gy (V5Gy. Additionally, the cumulative monitor units (MUs and treatment times of the different technologies were compared. All evaluation parameters were averaged over all 10 patients for each technique and planning modality. Results Depending on IMRT technique and TPS, the mean CI values of all patients ranged from 1.17 to 2.82; and mean HI values varied from 0.05 to 0.10. The mean values of the median doses of the spared parotid were 26.5Gy for RapidArc and 23Gy for VMAT, 14.1Gy for Tomo. For fixed gantry techniques 21Gy was achieved for step&shoot+KonRad, 17.0Gy for step&shoot+Panther DAO, 23.3Gy for step&shoot+Pinnacle and 18.6Gy for sliding window. V5Gy values were lowest for the sliding window IMRT technique (3499 ccm and largest for RapidArc (5480 ccm. The lowest mean MU value of 408 was achieved by Panther DAO, compared to 1140 for sliding window IMRT. Conclusions All

  19. Development of Head Injury Assessment Reference Values Based on NASA Injury Modeling

    Science.gov (United States)

    Somers, Jeffrey T.; Melvin, John W.; Tabiei, Ala; Lawrence, Charles; Ploutz-Snyder, Robert; Granderson, Bradley; Feiveson, Alan; Gernhardt, Michael; Patalak, John

    2011-01-01

    NASA is developing a new capsule-based, crewed vehicle that will land in the ocean, and the space agency desires to reduce the risk of injury from impact during these landings. Because landing impact occurs for each flight and the crew might need to perform egress tasks, current injury assessment reference values (IARV) were deemed insufficient. Because NASCAR occupant restraint systems are more effective than the systems used to determine the current IARVs and are similar to NASA s proposed restraint system, an analysis of NASCAR impacts was performed to develop new IARVs that may be more relevant to NASA s context of vehicle landing operations. Head IARVs associated with race car impacts were investigated by completing a detailed analysis of all of the 2002-2008 NASCAR impact data. Specific inclusion and exclusion criteria were used to select 4071 impacts from the 4015 recorder files provided (each file could contain multiple impact events). Of the 4071 accepted impacts, 274 were selected for numerical simulation using a custom NASCAR restraint system and Humanetics Hybrid-III 50th percentile numerical dummy model in LS-DYNA. Injury had occurred in 32 of the 274 selected impacts, and 27 of those injuries involved the head. A majority of the head injuries were mild concussions with or without brief loss of consciousness. The 242 non-injury impacts were randomly selected and representative of the range of crash dynamics present in the total set of 4071 impacts. Head dynamics data (head translational acceleration, translational change in velocity, rotational acceleration, rotational velocity, HIC-15, HIC-36, and the Head 3ms clip) were filtered according to SAE J211 specifications and then transformed to a log scale. The probability of head injury was estimated using a separate logistic regression analysis for each log-transformed predictor candidate. Using the log transformation constrains the estimated probability of injury to become negligible as IARVs approach

  20. Comparison of joint torque evoked with monopolar and tripolar-cuff electrodes.

    Science.gov (United States)

    Tarler, Matthew D; Mortimer, J Thomas

    2003-09-01

    Using a self-sizing spiral-cuff electrode placed on the sciatic nerve of the cat, the joint torque evoked with stimulation applied to contacts in a monopolar configuration was judged to be the same as the torque evoked by stimulation applied to contacts in a tripolar configuration. Experiments were carried out in six acute cat preparations. In each experiment, a 12-contact electrode was placed on the sciatic nerve and used to effect both the monopolar and tripolar electrode configurations. The ankle torque produced by electrically evoked isometric muscle contraction was measured in three dimensions: plantar flexion, internal rotation, and inversion. Based on the recorded ankle torque, qualitative and quantitative comparisons were performed to determine if any significant difference existed in the pattern or order in which motor nerve fibers were recruited. No significant difference was found at a 98% confidence interval in either the recruitment properties or the repeatability of the monopolar and tripolar configurations. Further, isolated activation of single fascicles within the sciatic nerve was observed. Once nerve fibers in a fascicle were activated, recruitment of that fascicle was modulated over the full range before "spill-over" excitation occurred in neighboring fascicles. These results indicate that a four contact, monopolar nerve-cuff electrode is a viable substitute for a 12 contact, tripolar nerve-cuff electrode. The results of this study are also consistent with the hypothesis that multicontact self-sizing spiral-cuff electrodes can be used in motor prostheses to provide selective control of many muscles. These findings should also apply to other neuroprostheses employing-cuff electrodes on nerve trunks.

  1. Practice type effects on head impact in collegiate football.

    Science.gov (United States)

    Reynolds, Bryson B; Patrie, James; Henry, Erich J; Goodkin, Howard P; Broshek, Donna K; Wintermark, Max; Druzgal, T Jason

    2016-02-01

    OBJECT IVE: This study directly compares the number and severity of subconcussive head impacts sustained during helmet-only practices, shell practices, full-pad practices, and competitive games in a National Collegiate Athletic Association (NCAA) Division I-A football team. The goal of the study was to determine whether subconcussive head impact in collegiate athletes varies with practice type, which is currently unregulated by the NCAA. Over an entire season, a cohort of 20 collegiate football players wore impact-sensing mastoid patches that measured the linear and rotational acceleration of all head impacts during a total of 890 athletic exposures. Data were analyzed to compare the number of head impacts, head impact burden, and average impact severity during helmet-only, shell, and full-pad practices, and games. Helmet-only, shell, and full-pad practices and games all significantly differed from each other (p ≤ 0.05) in the mean number of impacts for each event, with the number of impacts being greatest for games, then full-pad practices, then shell practices, and then helmet-only practices. The cumulative distributions for both linear and rotational acceleration differed between all event types (p football players.

  2. Characterization of music-evoked autobiographical memories.

    Science.gov (United States)

    Janata, Petr; Tomic, Stefan T; Rakowski, Sonja K

    2007-11-01

    Despite music's prominence in Western society and its importance to individuals in their daily lives, very little is known about the memories and emotions that are often evoked when hearing a piece of music from one's past. We examined the content of music-evoked autobiographical memories (MEAMs) using a novel approach for selecting stimuli from a large corpus of popular music, in both laboratory and online settings. A set of questionnaires probed the cognitive and affective properties of the evoked memories. On average, 30% of the song presentations evoked autobiographical memories, and the majority of songs also evoked various emotions, primarily positive, that were felt strongly. The third most common emotion was nostalgia. Analyses of written memory reports found both general and specific levels of autobiographical knowledge to be represented, and several social and situational contexts for memory formation were common across many memories. The findings indicate that excerpts of popular music serve as potent stimuli for studying the structure of autobiographical memories.

  3. Geometric calibration method for multiple-head cone-beam SPECT system

    International Nuclear Information System (INIS)

    Rizo, P.; Grangeat, P.; Guillemaud, R.

    1994-01-01

    A method is presented for estimating the geometrical parameters of cone beam systems with multiple heads, each head having its own orientation. In tomography, for each head, the relative position of the rotation axis and f the collimator do not change during the data acquisition. The authors thus can separate the parameters into intrinsic parameters and extrinsic parameters. The intrinsic parameters describe the detection system geometry and the extrinsic parameters the position of the detection system with respect to the rotation axis. Intrinsic parameters must be estimated each time the acquisition geometry is modified. Extrinsic parameters are estimated by minimizing the distances between the measured position of a point source projection and the computed position obtained using the estimated extrinsic parameters. The main advantage of this method is that the extrinsic parameters are only weakly correlated when the intrinsic parameters are known. Thus the authors can use any simple least square error minimization method to perform the estimation of the extrinsic parameters. Giving a fixed value to the distance between the point source and the rotation axis in the estimation process, ensures the coherence of the extrinsic parameters between each head. They show that with this calibration method, the full width at half maximum measured with point sources is very close to the theoretical one, and remains almost unchanged when more than one head is used. Simulation results and reconstructions on a Jaszczak phantom are presented that show the capabilities of this method

  4. Otolith function in patients with head trauma.

    Science.gov (United States)

    Lee, Jong Dae; Park, Moo Kyun; Lee, Byung Don; Park, Ji Yun; Lee, Tae Kyung; Sung, Ki-Bum

    2011-10-01

    This study evaluates the otolith function of patients with head trauma, postulating that otolith dysfunction is a cause of nonspecific dizziness after head trauma. We prospectively enrolled 28 patients referred within 3 months after head trauma between March 2007 and December 2009. Pure tone audiometry, caloric testing and otolith function tests, including cervical vestibular evoked myogenic potential (cVEMP) and subjective visual vertical (SVV) tests, were performed on all patients. The relationship between otolith function and otologic symptoms was analyzed. Of the 28 patients with head trauma, 18 complained of dizziness and 12 experienced hearing loss, including 6 patients who complained of both. On defining otolith dysfunction as an abnormal cVEMP or abnormal SVV, a significant difference in otolith dysfunction existed between the groups with and without dizziness [72 (13/18) vs. 20% (2/10)]. In contrast, no significant difference in otolith dysfunction was detected between the abnormal and normal hearing groups. A significant number of the patients who complained of nonspecific dizziness after trauma had abnormal otolith function. After trauma, when patients complain of dizziness, vestibular function tests, including otolith function tests, should be considered.

  5. Dynamic visual acuity during transient and sinusoidal yaw rotation in normal and unilaterally vestibulopathic humans.

    Science.gov (United States)

    Tian, J R; Shubayev, I; Demer, J L

    2001-03-01

    The vestibulo-ocular reflex (VOR) stabilizes gaze to permit clear vision during head movements. It has been supposed that VOR function might be inferred from dynamic visual acuity (DVA), the acuity during imposed head motion. We sought to determine effectiveness of DVA for detection and lateralization of unilateral vestibulopathy, using rigorous psychophysical methods. Seventeen normal and 11 unilaterally vestibulopathic subjects underwent measurement of optically best corrected DVA during head motion. A variable size letter "E" 6 m distant was displayed in oblique random orientations to determine binocular DVA by a computer controlled, forced choice method. Three types of whole-body yaw rotation were delivered by a servo-controlled chair synchronized with optotype presentation. Two types of motion were predictable: (1) steady-state 2.0-Hz rotation at 10-130 degrees/s peak velocity with repetitive optotype presentation only during head velocity exceeding 80% of peak; and (2) directionally predictable transients at peak accelerations of 1000, 1600 and 2800 degrees/s2 with optotype presentation for 300 ms. For neither of these predictable motions did DVA in vestibulopathic subjects significantly differ from normal, with suggestions from search coil recordings that this was due to predictive slow and saccadic eye movements. Unilaterally vestibulopathic subjects experienced a significant decrease in DVA from the static condition during ipsilesional rotation for all three peak head accelerations. Only during directionally unpredictable transients with 75 ms or 300 ms optotype presentation was the sensitivity of DVA in unilaterally vestibulopathic subjects significantly abnormal during ipsilesional rotation. The ipsilesional decrease in DVA with head motion was greater for 75 ms than 300 ms optotype presentation. Search coil recordings confirmed hypometric compensatory eye movements during DVA testing with unpredictable, ipsilesional rotation. Receiver

  6. Determining the Position of Head and Shoulders in Neurological Practice with the use of Cameras

    Directory of Open Access Journals (Sweden)

    P. Kutílek

    2011-01-01

    Full Text Available The posture of the head and shoulders can be influenced negatively by many diseases of the nervous system, visual and vestibular systems. We have designed a system and a set of procedures for evaluating the inclination (roll, flexion (pitch and rotation (yaw of the head and the inclination (roll and rotation (yaw of the shoulders. A new computational algorithm allows non-invasive and non-contact head and shoulder position measurement using two cameras mounted opposite each other, and the displacement of the optical axis of the cameras is also corrected.

  7. Fusarium spp. associated with head blight of wheat in South Africa

    Science.gov (United States)

    Fusarium head blight (FHB) of wheat is caused by numerous Fusarium species, including trichothecene-producers. In South Africa, FHB is mostly associated with irrigated wheat rotated with maize. Twenty symptomatic wheat heads were collected from four cultivars each in irrigated fields in the Northern...

  8. Relationship between vertebral artery blood flow in different head positions and vertigo.

    Science.gov (United States)

    Araz Server, Ela; Edizer, Deniz Tuna; Yiğit, Özgür; Yasak, Ahmet Görkem; Erdim, Çağrı

    2018-01-01

    To identify the vertebral artery blood flow in different head positions in patients with positional vertigo with no specific diagnosis. Patients with history of vestibular symptoms associated with changes in head position were enrolled into the study. Healthy volunteers were evaluated as control group. Doppler ultrasonography examination of the cervical segment of the vertebral arteries was performed under three different head positions: (i) supine position, (ii) head hyperextended and rotated to the right side and (iii) head hyperextended and rotated to the left side. In the study group, right and left vertebral artery blood flow was significantly lower in the ipsilateral hyperextended position compared to standard supine position (respectively p = .014; p = .001), but did not differ significantly when compared between the standard supine and contralateral hyperextended positions (respectively = .959; p = .669). In the control group, left and right vertebral artery blood flow did not differ significantly when the head was hyperextended to the right or left sides compared to standard supine position (p > .05). Our data demonstrated that the etiology of vestibular complaints in patients with undiagnosed positional vertigo might be related to impairment in vertebral artery blood flow according to head positions.

  9. Three-dimensional organization of vestibular related eye movements to rotational motion in pigeons

    Science.gov (United States)

    Dickman, J. D.; Beyer, M.; Hess, B. J.

    2000-01-01

    During rotational motions, compensatory eye movement adjustments must continually occur in order to maintain objects of visual interest as stable images on the retina. In the present study, the three-dimensional organization of the vestibulo-ocular reflex in pigeons was quantitatively examined. Rotations about different head axes produced horizontal, vertical, and torsional eye movements, whose component magnitude was dependent upon the cosine of the stimulus axis relative to the animal's visual axis. Thus, the three-dimensional organization of the VOR in pigeons appears to be compensatory for any direction of head rotation. Frequency responses of the horizontal, vertical, and torsional slow phase components exhibited high pass filter properties with dominant time constants of approximately 3 s.

  10. Experimental validation of a newly designed 6 degrees of freedom scanning laser head: Application to three-dimensional beam structure

    International Nuclear Information System (INIS)

    Di Maio, D.; Copertaro, E.

    2013-01-01

    A new scanning laser head is designed to use single Laser Doppler Vibrometer (LDV) for performing measurements up to 6 degrees of freedom (DOF) at a target. The scanning head is supported by a rotating hollow shaft, which allows the laser beam to travel up to the scanning head from an opposite direction where an LDV is set up. The scanning head is made of a set of two mirrors, which deflects the laser beam with an angle so that the rotation of the scanning head produces a conical scan. When measurements are performed at the focal point of the conical scan then three translational vibration components can be measured, otherwise the very small circle scan, before and after the focal point, can measure up to 6 degrees of freedom, including three translations and three rotations. This paper presents the 6DOF scanning head and the measurements of 3D operational deflection shapes of a test structure

  11. Mental rotation and the motor system: embodiment head over heels.

    Science.gov (United States)

    Krüger, Markus; Amorim, Michel-Ange; Ebersbach, Mirjam

    2014-01-01

    We examined whether body parts attached to abstract stimuli automatically force embodiment in a mental rotation task. In Experiment 1, standard cube combinations reflecting a human pose were added with (1) body parts on anatomically possible locations, (2) body parts on anatomically impossible locations, (3) colored end cubes, and (4) simple end cubes. Participants (N=30) had to decide whether two simultaneously presented stimuli, rotated in the picture plane, were identical or not. They were fastest and made less errors in the possible-body condition, but were slowest and least accurate in the impossible-body condition. A second experiment (N=32) replicated the results and ruled out that the poor performance in the impossible-body condition was due to the specific stimulus material. The findings of both experiments suggest that body parts automatically trigger embodiment, even when it is counterproductive and dramatically impairs performance, as in the impossible-body condition. It can furthermore be concluded that body parts cannot be used flexibly for spatial orientation in mental rotation tasks, compared to colored end cubes. Thus, embodiment appears to be a strong and inflexible mechanism that may, under certain conditions, even impede performance. Copyright © 2013 Elsevier B.V. All rights reserved.

  12. Functional Laterality of Task-Evoked Activation in Sensorimotor Cortex of Preterm Infants: An Optimized 3 T fMRI Study Employing a Customized Neonatal Head Coil.

    Directory of Open Access Journals (Sweden)

    Lukas Scheef

    Full Text Available Functional magnetic resonance imaging (fMRI in neonates has been introduced as a non-invasive method for studying sensorimotor processing in the developing brain. However, previous neonatal studies have delivered conflicting results regarding localization, lateralization, and directionality of blood oxygenation level dependent (BOLD responses in sensorimotor cortex (SMC. Amongst the confounding factors in interpreting neonatal fMRI studies include the use of standard adult MR-coils providing insufficient signal to noise, and liberal statistical thresholds, compromising clinical interpretation at the single subject level.Here, we employed a custom-designed neonatal MR-coil adapted and optimized to the head size of a newborn in order to improve robustness, reliability and validity of neonatal sensorimotor fMRI. Thirteen preterm infants with a median gestational age of 26 weeks were scanned at term-corrected age using a prototype 8-channel neonatal head coil at 3T (Achieva, Philips, Best, NL. Sensorimotor stimulation was elicited by passive extension/flexion of the elbow at 1 Hz in a block design. Analysis of temporal signal to noise ratio (tSNR was performed on the whole brain and the SMC, and was compared to data acquired with an 'adult' 8 channel head coil published previously. Task-evoked activation was determined by single-subject SPM8 analyses, thresholded at p < 0.05, whole-brain FWE-corrected.Using a custom-designed neonatal MR-coil, we found significant positive BOLD responses in contralateral SMC after unilateral passive sensorimotor stimulation in all neonates (analyses restricted to artifact-free data sets = 8/13. Improved imaging characteristics of the neonatal MR-coil were evidenced by additional phantom and in vivo tSNR measurements: phantom studies revealed a 240% global increase in tSNR; in vivo studies revealed a 73% global and a 55% local (SMC increase in tSNR, as compared to the 'adult' MR-coil.Our findings strengthen the

  13. Postural control and head stability during natural gaze behaviour in 6- to 12-year-old children.

    Science.gov (United States)

    Schärli, A M; van de Langenberg, R; Murer, K; Müller, R M

    2013-06-01

    We investigated how the influence of natural exploratory gaze behaviour on postural control develops from childhood into adulthood. In a cross-sectional design, we compared four age groups: 6-, 9-, 12-year-olds and young adults. Two experimental trials were performed: quiet stance with a fixed gaze (fixed) and quiet stance with natural exploratory gaze behaviour (exploratory). The latter was elicited by having participants watch an animated short film on a large screen in front of them. 3D head rotations in space and centre of pressure (COP) excursions on the ground plane were measured. Across conditions, both head rotation and COP displacement decreased with increasing age. Head movement was greater in the exploratory condition in all age groups. In all children-but not in adults-COP displacement was markedly greater in the exploratory condition. Bivariate correlations across groups showed highly significant positive correlations between COP displacement in ML direction and head rotation in yaw, roll, and pitch in both conditions. The regularity of COP displacements did not show a clear developmental trend, which indicates that COP dynamics were qualitatively similar across age groups. Together, the results suggest that the contribution of head movement to eye-head saccades decreases with age and that head instability-in part resulting from such gaze-related head movements-is an important limiting factor in children's postural control. The lack of head stabilisation might particularly affect children in everyday activities in which both postural control and visual exploration are required.

  14. Computing camera heading: A study

    Science.gov (United States)

    Zhang, John Jiaxiang

    2000-08-01

    An accurate estimate of the motion of a camera is a crucial first step for the 3D reconstruction of sites, objects, and buildings from video. Solutions to the camera heading problem can be readily applied to many areas, such as robotic navigation, surgical operation, video special effects, multimedia, and lately even in internet commerce. From image sequences of a real world scene, the problem is to calculate the directions of the camera translations. The presence of rotations makes this problem very hard. This is because rotations and translations can have similar effects on the images, and are thus hard to tell apart. However, the visual angles between the projection rays of point pairs are unaffected by rotations, and their changes over time contain sufficient information to determine the direction of camera translation. We developed a new formulation of the visual angle disparity approach, first introduced by Tomasi, to the camera heading problem. Our new derivation makes theoretical analysis possible. Most notably, a theorem is obtained that locates all possible singularities of the residual function for the underlying optimization problem. This allows identifying all computation trouble spots beforehand, and to design reliable and accurate computational optimization methods. A bootstrap-jackknife resampling method simultaneously reduces complexity and tolerates outliers well. Experiments with image sequences show accurate results when compared with the true camera motion as measured with mechanical devices.

  15. Pigeons (C. livia Follow Their Head during Turning Flight: Head Stabilization Underlies the Visual Control of Flight

    Directory of Open Access Journals (Sweden)

    Ivo G. Ros

    2017-12-01

    Full Text Available Similar flight control principles operate across insect and vertebrate fliers. These principles indicate that robust solutions have evolved to meet complex behavioral challenges. Following from studies of visual and cervical feedback control of flight in insects, we investigate the role of head stabilization in providing feedback cues for controlling turning flight in pigeons. Based on previous observations that the eyes of pigeons remain at relatively fixed orientations within the head during flight, we test potential sensory control inputs derived from head and body movements during 90° aerial turns. We observe that periods of angular head stabilization alternate with rapid head repositioning movements (head saccades, and confirm that control of head motion is decoupled from aerodynamic and inertial forces acting on the bird's continuously rotating body during turning flapping flight. Visual cues inferred from head saccades correlate with changes in flight trajectory; whereas the magnitude of neck bending predicts angular changes in body position. The control of head motion to stabilize a pigeon's gaze may therefore facilitate extraction of important motion cues, in addition to offering mechanisms for controlling body and wing movements. Strong similarities between the sensory flight control of birds and insects may also inspire novel designs of robust controllers for human-engineered autonomous aerial vehicles.

  16. Beyond the evoked/intrinsic neural process dichotomy

    Directory of Open Access Journals (Sweden)

    Taylor Bolt

    2018-03-01

    Full Text Available Contemporary functional neuroimaging research has increasingly focused on characterization of intrinsic or “spontaneous” brain activity. Analysis of intrinsic activity is often contrasted with analysis of task-evoked activity that has traditionally been the focus of cognitive neuroscience. But does this evoked/intrinsic dichotomy adequately characterize human brain function? Based on empirical data demonstrating a close functional interdependence between intrinsic and task-evoked activity, we argue that the dichotomy between intrinsic and task-evoked activity as unobserved contributions to brain activity is artificial. We present an alternative picture of brain function in which the brain’s spatiotemporal dynamics do not consist of separable intrinsic and task-evoked components, but reflect the enaction of a system of mutual constraints to move the brain into and out of task-appropriate functional configurations. According to this alternative picture, cognitive neuroscientists are tasked with describing both the temporal trajectory of brain activity patterns across time, and the modulation of this trajectory by task states, without separating this process into intrinsic and task-evoked components. We argue that this alternative picture of brain function is best captured in a novel explanatory framework called enabling constraint. Overall, these insights call for a reconceptualization of functional brain activity, and should drive future methodological and empirical efforts.

  17. Pisodonophis boro (ophichthidae: anguilliformes): specialization for head-first and tail-first burrowing?

    Science.gov (United States)

    De Schepper, Natalie; De Kegel, Barbara; Adriaens, Dominique

    2007-02-01

    The rice paddy eel, Pisodonophis boro (P. boro), is of special interest because of its peculiar burrowing habits. P. boro penetrates the substrate tail-first, a technique common for ophichthids, but it is able to burrow head-first as well. P. boro exhibits three feeding modes: inertial feeding, grasping, and spinning. Rotational feeding is a highly specialized feeding mode, adopted by several elongate, aquatic vertebrates and it is likely that some morphological modifications are related to this feeding mode. The detailed morphology of the head and tail of P. boro is examined with the goal to apportion the anatomical specializations among head-first burrowing, tail-first burrowing, and rotational feeding. The reduced eyes, covered with thick corneas may be beneficial for protection during head-first burrowing, but at the same time decreased visual acuity may have an impact on other sensory systems (e.g. cephalic lateral line system). The elongated and pointed shape of the skull is beneficial for substrate penetration. The cranial bones and their joints, which are fortified, are advantageous for resisting high mechanical loads during head-first burrowing. The aponeurotic connection between epaxial and jaw muscles is considered beneficial for transferring these forces from the body to the head during rotational feeding. Hypertrophied jaw muscles facilitate a powerful bite, which is required to hold prey during spinning movements and variability in the fiber angles of subdivisions of jaw muscles may be beneficial for preventing the lower jaw from being dislodged or opened. Furthermore, firm upper (premaxillo-ethmovomerine complex) and lower jaws (with robust coronoid processes) and high neurocranial rigidity are advantageous for a solid grip to hold prey during rotational feeding. The pointed shape of the tail and the consolidated caudal skeleton are beneficial for their tail-first burrowing habits. It is quite likely that the reduction of the caudal musculature is

  18. A new model for diffuse brain injury by rotational acceleration: I model, gross appearance, and astrocytosis.

    Science.gov (United States)

    Gutierrez, E; Huang, Y; Haglid, K; Bao, F; Hansson, H A; Hamberger, A; Viano, D

    2001-03-01

    Rapid head rotation is a major cause of brain damage in automobile crashes and falls. This report details a new model for rotational acceleration about the center of mass of the rabbit head. This allows the study of brain injury without translational acceleration of the head. Impact from a pneumatic cylinder was transferred to the skull surface to cause a half-sine peak acceleration of 2.1 x 10(5) rad/s2 and 0.96-ms pulse duration. Extensive subarachnoid hemorrhages and small focal bleedings were observed in the brain tissue. A pronounced reactive astrogliosis was found 8-14 days after trauma, both as networks around the focal hemorrhages and more diffusely in several brain regions. Astrocytosis was prominent in the gray matter of the cerebral cortex, layers II-V, and in the granule cell layer and around the axons of the pyramidal neurons in the hippocampus. The nuclei of cranial nerves, such as the hypoglossal and facial nerves, also showed intense astrocytosis. The new model allows study of brain injuries from head rotation in the absence of translational influences.

  19. Recording visual evoked potentials and auditory evoked P300 at 9.4T static magnetic field.

    Science.gov (United States)

    Arrubla, Jorge; Neuner, Irene; Hahn, David; Boers, Frank; Shah, N Jon

    2013-01-01

    Simultaneous recording of electroencephalography (EEG) and functional magnetic resonance imaging (fMRI) has shown a number of advantages that make this multimodal technique superior to fMRI alone. The feasibility of recording EEG at ultra-high static magnetic field up to 9.4 T was recently demonstrated and promises to be implemented soon in fMRI studies at ultra high magnetic fields. Recording visual evoked potentials are expected to be amongst the most simple for simultaneous EEG/fMRI at ultra-high magnetic field due to the easy assessment of the visual cortex. Auditory evoked P300 measurements are of interest since it is believed that they represent the earliest stage of cognitive processing. In this study, we investigate the feasibility of recording visual evoked potentials and auditory evoked P300 in a 9.4 T static magnetic field. For this purpose, EEG data were recorded from 26 healthy volunteers inside a 9.4 T MR scanner using a 32-channel MR compatible EEG system. Visual stimulation and auditory oddball paradigm were presented in order to elicit evoked related potentials (ERP). Recordings made outside the scanner were performed using the same stimuli and EEG system for comparison purposes. We were able to retrieve visual P100 and auditory P300 evoked potentials at 9.4 T static magnetic field after correction of the ballistocardiogram artefact using independent component analysis. The latencies of the ERPs recorded at 9.4 T were not different from those recorded at 0 T. The amplitudes of ERPs were higher at 9.4 T when compared to recordings at 0 T. Nevertheless, it seems that the increased amplitudes of the ERPs are due to the effect of the ultra-high field on the EEG recording system rather than alteration in the intrinsic processes that generate the electrophysiological responses.

  20. Rapid motor learning in the translational vestibulo-ocular reflex

    Science.gov (United States)

    Zhou, Wu; Weldon, Patrick; Tang, Bingfeng; King, W. M.; Shelhamer, M. J. (Principal Investigator)

    2003-01-01

    Motor learning was induced in the translational vestibulo-ocular reflex (TVOR) when monkeys were repeatedly subjected to a brief (0.5 sec) head translation while they tried to maintain binocular fixation on a visual target for juice rewards. If the target was world-fixed, the initial eye speed of the TVOR gradually increased; if the target was head-fixed, the initial eye speed of the TVOR gradually decreased. The rate of learning acquisition was very rapid, with a time constant of approximately 100 trials, which was equivalent to or=1 d without any reinforcement, indicating induction of long-term synaptic plasticity. Although the learning generalized to targets with different viewing distances and to head translations with different accelerations, it was highly specific for the particular combination of head motion and evoked eye movement associated with the training. For example, it was specific to the modality of the stimulus (translation vs rotation) and the direction of the evoked eye movement in the training. Furthermore, when one eye was aligned with the heading direction so that it remained motionless during training, learning was not expressed in this eye, but only in the other nonaligned eye. These specificities show that the learning sites are neither in the sensory nor the motor limb of the reflex but in the sensory-motor transformation stage of the reflex. The dependence of the learning on both head motion and evoked eye movement suggests that Hebbian learning may be one of the underlying cellular mechanisms.

  1. Normalization of auditory evoked potential and visual evoked potential in patients with idiot savant.

    Science.gov (United States)

    Chen, X; Zhang, M; Wang, J; Lou, F; Liang, J

    1999-03-01

    To investigate the variations of auditory evoked potentials (AEP) and visual evoked potentials (VEP) of patients with idiot savant (IS) syndrome. Both AEP and VEP were recorded from 7 patients with IS syndrome, 21 mentally retarded (MR) children without the syndrome and 21 normally age-matched controls, using a Dantec concerto SEEG-16 BEAM instrument. Both AEP and VEP of MR group showed significantly longer latencies (P1 and P2 latencies of AEP, P savant syndrome presented normalized AEP and VEP.

  2. Influence of Head Motion on the Accuracy of 3D Reconstruction with Cone-Beam CT: Landmark Identification Errors in Maxillofacial Surface Model.

    Directory of Open Access Journals (Sweden)

    Kyung-Min Lee

    Full Text Available The purpose of this study was to investigate the influence of head motion on the accuracy of three-dimensional (3D reconstruction with cone-beam computed tomography (CBCT scan.Fifteen dry skulls were incorporated into a motion controller which simulated four types of head motion during CBCT scan: 2 horizontal rotations (to the right/to the left and 2 vertical rotations (upward/downward. Each movement was triggered to occur at the start of the scan for 1 second by remote control. Four maxillofacial surface models with head motion and one control surface model without motion were obtained for each skull. Nine landmarks were identified on the five maxillofacial surface models for each skull, and landmark identification errors were compared between the control model and each of the models with head motion.Rendered surface models with head motion were similar to the control model in appearance; however, the landmark identification errors showed larger values in models with head motion than in the control. In particular, the Porion in the horizontal rotation models presented statistically significant differences (P < .05. Statistically significant difference in the errors between the right and left side landmark was present in the left side rotation which was opposite direction to the scanner rotation (P < .05.Patient movement during CBCT scan might cause landmark identification errors on the 3D surface model in relation to the direction of the scanner rotation. Clinicians should take this into consideration to prevent patient movement during CBCT scan, particularly horizontal movement.

  3. Visually Evoked Spiking Evolves While Spontaneous Ongoing Dynamics Persist

    Science.gov (United States)

    Huys, Raoul; Jirsa, Viktor K.; Darokhan, Ziauddin; Valentiniene, Sonata; Roland, Per E.

    2016-01-01

    Neurons in the primary visual cortex spontaneously spike even when there are no visual stimuli. It is unknown whether the spiking evoked by visual stimuli is just a modification of the spontaneous ongoing cortical spiking dynamics or whether the spontaneous spiking state disappears and is replaced by evoked spiking. This study of laminar recordings of spontaneous spiking and visually evoked spiking of neurons in the ferret primary visual cortex shows that the spiking dynamics does not change: the spontaneous spiking as well as evoked spiking is controlled by a stable and persisting fixed point attractor. Its existence guarantees that evoked spiking return to the spontaneous state. However, the spontaneous ongoing spiking state and the visual evoked spiking states are qualitatively different and are separated by a threshold (separatrix). The functional advantage of this organization is that it avoids the need for a system reorganization following visual stimulation, and impedes the transition of spontaneous spiking to evoked spiking and the propagation of spontaneous spiking from layer 4 to layers 2–3. PMID:26778982

  4. Artificial gravity: head movements during short-radius centrifugation

    NARCIS (Netherlands)

    Young, L. R.; Hecht, H.; Lyne, L. E.; Sienko, K. H.; Cheung, C. C.; Kavelaars, J.

    2001-01-01

    Short-radius centrifugation is a potential countermeasure to long-term weightlessness. Unfortunately, head movements in a rotating environment induce serious discomfort, non-compensatory vestibulo-ocular reflexes, and subjective illusions of body tilt. In two experiments we investigated the effects

  5. The incidence of pathologic changes of the long head of the biceps tendon.

    Science.gov (United States)

    Murthi, A M; Vosburgh, C L; Neviaser, T J

    2000-01-01

    The incidence of primary and secondary bicipital tendinitis remains unknown. In our prospective study, 200 consecutive shoulders underwent arthroscopic subacromial decompression for impingement syndrome. A biceps tenodesis was performed in 80 shoulders (40%) featuring macroscopic degeneration of the long head of the biceps; rotator cuff tears were apparent in 91% of these shoulders, the mean patient age being 55 years. In each of 120 shoulders (60%), an extraarticular tenosynovectomy was performed, and histopathologic studies revealed chronic inflammation in 63% and fibrotic degeneration in 13% of the specimens; rotator cuff tears were evident in 70% (23% full thickness) of these cases, the mean patient age being 47 years. In addition, when glenohumeral arthritis was present, it was uniformly associated with pathologic biceps tenosynovium. In summary, the high incidence of chronic inflammation of the long head of the biceps in shoulders with benign-appearing intraarticular portions viewed arthroscopically is significant, and long head of the biceps disease should also be considered in patients with painful rotator cuff disease and arthritic shoulder conditions.

  6. Observational study of differences in head position for high notes in famous classical and non-classical male singers.

    Science.gov (United States)

    Amarante Andrade, Pedro; Švec, Jan G

    2016-07-01

    Differences in classical and non-classical singing are due primarily to aesthetic style requirements. The head position can affect the sound quality. This study aimed at comparing the head position for famous classical and non-classical male singers performing high notes. Images of 39 Western classical and 34 non-classical male singers during live performances were obtained from YouTube. Ten raters evaluated the frontal rotational head position (depression versus elevation) and transverse head position (retraction versus protraction) visually using a visual analogue scale. The results showed a significant difference for frontal rotational head position. Most non-classical singers in the sample elevated their heads for high notes while the classical singers were observed to keep it around the neutral position. This difference may be attributed to different singing techniques and phonatory system adjustments utilized by each group.

  7. Brain-immune interaction accompanying odor-evoked autobiographic memory.

    Science.gov (United States)

    Matsunaga, Masahiro; Bai, Yu; Yamakawa, Kaori; Toyama, Asako; Kashiwagi, Mitsuyoshi; Fukuda, Kazuyuki; Oshida, Akiko; Sanada, Kazue; Fukuyama, Seisuke; Shinoda, Jun; Yamada, Jitsuhiro; Sadato, Norihiro; Ohira, Hideki

    2013-01-01

    The phenomenon in which a certain smell evokes a specific memory is known as the Proust phenomenon. Odor-evoked autobiographic memories are more emotional than those elicited by other sensory stimuli. The results of our previous study indicated that odor-evoked autobiographic memory accompanied by positive emotions has remarkable effects on various psychological and physiological activities, including the secretion of cytokines, which are immune-signaling molecules that modulate systemic inflammation. In this study, we aimed to clarify the neural substrates associated with the interaction between odor-evoked autobiographic memory and peripheral circulating cytokines. We recruited healthy male and female volunteers and investigated the association between brain responses and the concentration of several cytokines in the plasma by using positron emission tomography (PET) recordings when an autographic memory was evoked in participants by asking them to smell an odor that was nostalgic to them. Participants experienced positive emotions and autobiographic memories when nostalgic odors were presented to them. The levels of peripheral proinflammatory cytokines, such as the tumor necrosis factor-α (TNF-α) and interferon-γ (IFN-γ), were significantly reduced after experiencing odor-evoked autobiographic memory. Subtraction analysis of PET images indicated that the medial orbitofrontal cortex (mOFC) and precuneus/posterior cingulate cortex (PCC) were significantly activated during experiences of odor-evoked autobiographic memory. Furthermore, a correlation analysis indicated that activities of the mOFC and precuneus/PCC were negatively correlated with IFN-γ concentration. These results indicate that the neural networks including the precuneus/PCC and mOFC might regulate the secretion of peripheral proinflammatory cytokines during the experience of odor-evoked autobiographic memories accompanied with positive emotions.

  8. Brain–Immune Interaction Accompanying Odor-Evoked Autobiographic Memory

    Science.gov (United States)

    Matsunaga, Masahiro; Bai, Yu; Yamakawa, Kaori; Toyama, Asako; Kashiwagi, Mitsuyoshi; Fukuda, Kazuyuki; Oshida, Akiko; Sanada, Kazue; Fukuyama, Seisuke; Shinoda, Jun; Yamada, Jitsuhiro; Sadato, Norihiro; Ohira, Hideki

    2013-01-01

    The phenomenon in which a certain smell evokes a specific memory is known as the Proust phenomenon. Odor-evoked autobiographic memories are more emotional than those elicited by other sensory stimuli. The results of our previous study indicated that odor-evoked autobiographic memory accompanied by positive emotions has remarkable effects on various psychological and physiological activities, including the secretion of cytokines, which are immune-signaling molecules that modulate systemic inflammation. In this study, we aimed to clarify the neural substrates associated with the interaction between odor-evoked autobiographic memory and peripheral circulating cytokines. We recruited healthy male and female volunteers and investigated the association between brain responses and the concentration of several cytokines in the plasma by using positron emission tomography (PET) recordings when an autographic memory was evoked in participants by asking them to smell an odor that was nostalgic to them. Participants experienced positive emotions and autobiographic memories when nostalgic odors were presented to them. The levels of peripheral proinflammatory cytokines, such as the tumor necrosis factor-α (TNF-α) and interferon-γ (IFN-γ), were significantly reduced after experiencing odor-evoked autobiographic memory. Subtraction analysis of PET images indicated that the medial orbitofrontal cortex (mOFC) and precuneus/posterior cingulate cortex (PCC) were significantly activated during experiences of odor-evoked autobiographic memory. Furthermore, a correlation analysis indicated that activities of the mOFC and precuneus/PCC were negatively correlated with IFN-γ concentration. These results indicate that the neural networks including the precuneus/PCC and mOFC might regulate the secretion of peripheral proinflammatory cytokines during the experience of odor-evoked autobiographic memories accompanied with positive emotions. PMID:23977312

  9. Brain-immune interaction accompanying odor-evoked autobiographic memory.

    Directory of Open Access Journals (Sweden)

    Masahiro Matsunaga

    Full Text Available The phenomenon in which a certain smell evokes a specific memory is known as the Proust phenomenon. Odor-evoked autobiographic memories are more emotional than those elicited by other sensory stimuli. The results of our previous study indicated that odor-evoked autobiographic memory accompanied by positive emotions has remarkable effects on various psychological and physiological activities, including the secretion of cytokines, which are immune-signaling molecules that modulate systemic inflammation. In this study, we aimed to clarify the neural substrates associated with the interaction between odor-evoked autobiographic memory and peripheral circulating cytokines. We recruited healthy male and female volunteers and investigated the association between brain responses and the concentration of several cytokines in the plasma by using positron emission tomography (PET recordings when an autographic memory was evoked in participants by asking them to smell an odor that was nostalgic to them. Participants experienced positive emotions and autobiographic memories when nostalgic odors were presented to them. The levels of peripheral proinflammatory cytokines, such as the tumor necrosis factor-α (TNF-α and interferon-γ (IFN-γ, were significantly reduced after experiencing odor-evoked autobiographic memory. Subtraction analysis of PET images indicated that the medial orbitofrontal cortex (mOFC and precuneus/posterior cingulate cortex (PCC were significantly activated during experiences of odor-evoked autobiographic memory. Furthermore, a correlation analysis indicated that activities of the mOFC and precuneus/PCC were negatively correlated with IFN-γ concentration. These results indicate that the neural networks including the precuneus/PCC and mOFC might regulate the secretion of peripheral proinflammatory cytokines during the experience of odor-evoked autobiographic memories accompanied with positive emotions.

  10. Effects of Sex and Event Type on Head Impact in Collegiate Soccer

    Science.gov (United States)

    Reynolds, Bryson B.; Patrie, James; Henry, Erich J.; Goodkin, Howard P.; Broshek, Donna K.; Wintermark, Max; Druzgal, T. Jason

    2017-01-01

    Background: The effects of head impact in sports are of growing interest for clinicians, scientists, and athletes. Soccer is the most popular sport worldwide, but the burden of head impact in collegiate soccer is still unknown. Purpose: To quantify head impact associated with practicing and playing collegiate soccer using wearable accelerometers. Study Design: Descriptive epidemiological study. Methods: Mastoid patch accelerometers were used to quantify head impact in soccer, examining differences in head impact as a function of sex and event type (practice vs game). Seven female and 14 male collegiate soccer players wore mastoid patch accelerometers that measured head impacts during team events. Data were summarized for each athletic exposure, and statistical analyses evaluated the mean number of impacts, mean peak linear acceleration, mean peak rotational acceleration, and cumulative linear and rotational acceleration, each grouped by sex and event type. Results: There were no differences in the frequency or severity of head impacts between men’s and women’s soccer practices. For men’s soccer, games resulted in 285% more head impacts than practices, but there were no event-type differences in mean impact severity. Men’s soccer games resulted in more head impacts than practices across nearly all measured impact severities, which also resulted in men’s soccer games producing a greater cumulative impact burden. Conclusion: Similar to other sports, men’s soccer games have a greater impact burden when compared with practices, and this effect is driven by the quantity rather than severity of head impacts. In contrast, there were no differences in the quantity or severity of head impacts in men’s and women’s soccer practices. These data could prompt discussions of practical concern to collegiate soccer, such as understanding sex differences in head impact and whether games disproportionately contribute to an athlete’s head impact burden. PMID:28491885

  11. Predicting superdeformed rotational band-head spin in A ∼ 190 ...

    Indian Academy of Sciences (India)

    PACS No. 21.60.−n. 1. Introduction. Superdeformed (SD) nuclei are one of the most challenging and ... like A ∼ 60, 80, 130, 150 and 190 [2,3]. ..... work and the research is progressing to give systematic features of rotational bands of SD.

  12. MRI of rotator cuff muscle atrophy in relation to glenohumeral joint incongruence in brachial plexus birth injury

    International Nuclear Information System (INIS)

    Poeyhiae, Tiina H.; Nietosvaara, Yrjaenae A.; Peltonen, Jari I.; Remes, Ville M.; Kirjavainen, Mikko O.; Lamminen, Antti E.

    2005-01-01

    Purpose: To evaluate rotator cuff muscles and the glenohumeral (GH) joint in brachial plexus birth injury (BPBI) using MRI and to determine whether any correlation exists between muscular abnormality and the development of glenoid dysplasia and GH joint incongruity. Thirty-nine consecutive BPBI patients with internal rotation contracture or absent active external rotation of the shoulder joint were examined clinically and imaged with MRI. In the physical examination, passive external rotation was measured to evaluate internal rotation contracture. Both shoulders were imaged and the glenoscapular angle, percentage of humeral head anterior to the middle of the glenoid fossa (PHHA) and the greatest thickness of the subscapular, infraspinous and supraspinous muscles were measured. The muscle ratio between the affected side and the normal side was calculated to exclude age variation in the assessment of muscle atrophy. All muscles of the rotator cuff were atrophic, with the subscapular and infraspinous muscles being most severely affected. A correlation was found between the percentage of humeral head anterior to the middle of the glenoid fossa (PHHA) and the extent of subscapular muscle atrophy (r s =0.45, P=0.01), as well as between its ratio (r s =0.5, P P=0.01). Severity of rotator cuff muscle atrophy correlated with increased glenoid retroversion and the degree of internal rotation contracture. Glenoid retroversion and subluxation of the humeral head are common in patients with BPBI. All rotator cuff muscles are atrophic, especially the subscapular muscle. Muscle atrophy due to neurogenic damage apparently results in an imbalance of the shoulder muscles and progressive retroversion and subluxation of the GH joint, which in turn lead to internal rotation contracture and deformation of the joint. (orig.)

  13. Rotations in a Vertebrate Setting

    Science.gov (United States)

    McCollum, Gin

    2003-05-01

    Rotational movements of the head are often considered to be measured in a single three dimensional coordinate system implemented by the semicircular canals of the vestibular system of the inner ear. However, the vertebrate body -- including the nervous system -- obeys rectangular symmetries alien to rotation groups. At best, nervous systems mimic the physical rotation group in a fragmented way, only partially reintegrating physical movements in whole organism responses. The vestibular canal reference frame is widely used in nervous systems, for example by eye movements. It is used to some extent even in the cerebrum, as evidenced by the remission of hemineglect -- in which half of space is ignored -- when the vestibular system is stimulated. However, reintegration of space by the organism remains incomplete. For example, compensatory eye movements (which in most cases aid visual fixation) may disagree with conscious self-motion perception. In addition, movement-induced nausea, illusions, and cue-free perceptions demonstrate symmetry breaking or incomplete spatial symmetries. As part of a long-term project to investigate rotation groups in nervous systems, we have analyzed the symmetry group of a primary vestibulo-spinal projection.

  14. Heading Estimation for Indoor Pedestrian Navigation Using a Smartphone in the Pocket

    Directory of Open Access Journals (Sweden)

    Zhi-An Deng

    2015-08-01

    Full Text Available Heading estimation is a central problem for indoor pedestrian navigation using the pervasively available smartphone. For smartphones placed in a pocket, one of the most popular device positions, the essential challenges in heading estimation are the changing device coordinate system and the severe indoor magnetic perturbations. To address these challenges, we propose a novel heading estimation approach based on a rotation matrix and principal component analysis (PCA. Firstly, through a related rotation matrix, we project the acceleration signals into a reference coordinate system (RCS, where a more accurate estimation of the horizontal plane of the acceleration signal is obtained. Then, we utilize PCA over the horizontal plane of acceleration signals for local walking direction extraction. Finally, in order to translate the local walking direction into the global one, we develop a calibration process without requiring noisy compass readings. Besides, a turn detection algorithm is proposed to improve the heading estimation accuracy. Experimental results show that our approach outperforms the traditional uDirect and PCA-based approaches in terms of accuracy and feasibility.

  15. Coordinated Control of Three-Dimensional Components of Smooth Pursuit to Rotating and Translating Textures.

    Science.gov (United States)

    Edinger, Janick; Pai, Dinesh K; Spering, Miriam

    2017-01-01

    The neural control of pursuit eye movements to visual textures that simultaneously translate and rotate has largely been neglected. Here we propose that pursuit of such targets-texture pursuit-is a fully three-dimensional task that utilizes all three degrees of freedom of the eye, including torsion. Head-fixed healthy human adults (n = 8) tracked a translating and rotating random dot pattern, shown on a computer monitor, with their eyes. Horizontal, vertical, and torsional eye positions were recorded with a head-mounted eye tracker. The torsional component of pursuit is a function of the rotation of the texture, aligned with its visual properties. We observed distinct behaviors between those trials in which stimulus rotation was in the same direction as that of a rolling ball ("natural") in comparison to those with the opposite rotation ("unnatural"): Natural rotation enhanced and unnatural rotation reversed torsional velocity during pursuit, as compared to torsion triggered by a nonrotating random dot pattern. Natural rotation also triggered pursuit with a higher horizontal velocity gain and fewer and smaller corrective saccades. Furthermore, we show that horizontal corrective saccades are synchronized with torsional corrective saccades, indicating temporal coupling of horizontal and torsional saccade control. Pursuit eye movements have a torsional component that depends on the visual stimulus. Horizontal and torsional eye movements are separated in the motor periphery. Our findings suggest that translational and rotational motion signals might be coordinated in descending pursuit pathways.

  16. Head and Helmet Biodynamics and Tracking Performance in Vibration Environments

    National Research Council Canada - National Science Library

    Smith, Suzanne D; Smith, Jeanne A

    2006-01-01

    ...) and Up (40" elevation, 0" azimuth)], and three helmet CCs were tested. The overall head, helmet, and helmet slippage displacement rotations, and rms tracking error and percent time-on-target were evaluated...

  17. The new INRIM rotating encoder angle comparator (REAC)

    International Nuclear Information System (INIS)

    Pisani, Marco; Astrua, Milena

    2017-01-01

    A novel angle comparator has been built and tested at INRIM. The device is based on a double air bearing structure embedding a continuously rotating encoder, which is read by two heads: one fixed to the base of the comparator and a second fixed to the upper moving part of the comparator. The phase measurement between the two heads’ signals is proportional to the relative angle suspended between them (and, therefore, the angle between the base and the upper, movable part of the comparator). The advantage of this solution is to reduce the encoder graduation errors and to cancel the cyclic errors due to the interpolation of the encoder lines. By using only two pairs of reading heads, we have achieved an intrinsic accuracy of  ±0.04″ (rectangular distribution) that can be reduced through self-calibration. The residual cyclic errors have shown to be less than 0.01″ peak-to-peak. The random fluctuations are less than 0.01″ rms on a 100 s time interval. A further advantage of the rotating encoder is the intrinsic knowledge of the absolute position without the need of a zeroing procedure. Construction details of the rotating encoder angle comparator (REAC), characterization tests, and examples of practical use are given. (paper)

  18. Suction power output and the inertial cost of rotating the neurocranium to generate suction in fish.

    Science.gov (United States)

    Van Wassenbergh, Sam; Day, Steven W; Hernández, L Patricia; Higham, Timothy E; Skorczewski, Tyler

    2015-05-07

    To expand the buccal cavity, many suction-feeding fishes rely on a considerable contribution from dorsal rotation of the dorsal part of the head including the brains, eyes, and several bones forming the braincase and skull roof (jointly referred to as the neurocranium). As the neurocranium takes up a large part of the total mass of the head, this rotation may incur a considerable inertial cost. If so, this would suggest a significant selective pressure on the kinematics and mass distribution of the neurocranium of suction feeders. Here, an inverse dynamic model is formulated to calculate the instantaneous power required to rotate the neurocranium, approximated by a quarter ellipsoid volume of homogeneous density, as well as to calculate the instantaneous suction power based on intra-oral pressure and head volume quantifications. We applied this model to largemouth bass (Micropterus salmoides) and found that the power required to rotate the neurocranium accounts for only about 4% of the power required to suck water into the mouth. Furthermore, recovery of kinetic energy from the rotating neurocranium converted into suction work may be possible during the phase of neurocranial deceleration. Thus, we suggest that only a negligible proportion of the power output of the feeding muscles is lost as inertial costs in the largemouth bass. Consequently, the feeding performance of piscivorous suction feeders with generalised morphology, comparable to our model species, is not limited by neurocranial motion during head expansion. This suggests that it is thus not likely to be a factor of importance in the evolution of cranial shape and size. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Detection of treatment setup errors between two CT scans for patients with head and neck cancer

    International Nuclear Information System (INIS)

    Ezzell, Leah C.; Hansen, Eric K.; Quivey, Jeanne M.; Xia Ping

    2007-01-01

    Accuracy of treatment setup for head and neck patients undergoing intensity-modulated radiation therapy is of paramount importance. The conventional method using orthogonal portal images can only detect translational setup errors while the most frequent setup errors for head and neck patients could be rotational errors. With the rapid development of image-guided radiotherapy, three-dimensional images are readily acquired and can be used to detect both translational and rotational setup errors. The purpose of this study is to determine the significance of rotational variations between two planning CT scans acquired for each of eight head and neck patients, who experienced substantial weight loss or tumor shrinkage. To this end, using a rigid body assumption, we developed an in-house computer program that utilizes matrix transformations to align point bony landmarks with an incremental best-fit routine. The program returns the quantified translational and rotational shifts needed to align the scans of each patient. The program was tested using a phantom for a set of known translational and rotational shifts. For comparison, a commercial treatment planning system was used to register the two CT scans and estimate the translational errors for these patients. For the eight patients, we found that the average magnitudes and standard deviations of the rotational shifts about the transverse, anterior-posterior, and longitudinal axes were 1.7±2.3 deg., 0.8±0.7 deg., and 1.8±1.1 deg., respectively. The average magnitudes and standard deviations of the translational shifts were 2.5±2.6 mm, 2.9±2.8 mm, 2.7±1.7 mm while the differences detected between our program and the CT-CT fusion method were 1.8±1.3 mm, 3.3±5.4 mm, and 3.0±3.4 mm in the left-right, anterior-posterior, and superior-inferior directions, respectively. A trend of larger rotational errors resulting in larger translational differences between the two methods was observed. In conclusion, conventional

  20. Towards a neural basis of music-evoked emotions.

    Science.gov (United States)

    Koelsch, Stefan

    2010-03-01

    Music is capable of evoking exceptionally strong emotions and of reliably affecting the mood of individuals. Functional neuroimaging and lesion studies show that music-evoked emotions can modulate activity in virtually all limbic and paralimbic brain structures. These structures are crucially involved in the initiation, generation, detection, maintenance, regulation and termination of emotions that have survival value for the individual and the species. Therefore, at least some music-evoked emotions involve the very core of evolutionarily adaptive neuroaffective mechanisms. Because dysfunctions in these structures are related to emotional disorders, a better understanding of music-evoked emotions and their neural correlates can lead to a more systematic and effective use of music in therapy. Copyright 2010 Elsevier Ltd. All rights reserved.

  1. Ampleness of head movements of children and adolescents with sensorineural hearing loss.

    Science.gov (United States)

    de Souza Melo, Renato

    2017-02-01

    Head movements are controlled by the vestibular system. Children with sensorineural hearing loss can present restrictions in ampleness of head movements due to damage in the vestibule-cochlear systems, resulting from injury in the inner ear. To evaluate the ampleness of head movements of children with normal hearing and children with sensorineural hearing loss and compare data between groups. Cross-sectional study that evaluated the ampleness of head movements of 96 students, being 48 with normal hearing and 48 with sensorineural hearing loss, of both sexes, with aged between 7 and 18 years old. The performance of ampleness of head movements was analyzed by a manual goniometric evaluation, according the references proposed by Marques. To the statistical analysis we used the t-Student test in case of normality of the data or the Mann-Whitney test when did not applied the suppositions of normality. Hearing loss children showed less mean in ampleness of all movements of head compared to normal hearing children, pointing difference to movements of flexion (p = 0,001), lateral inclination to the right (p = 0,025) and lateral rotation to the left (p = 0,021). Hearing loss children showed reduction in the ampleness of these head movements: flexion, lateral inclination to the right and lateral rotation to the left compared to normal hearing children. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  2. Otolithic disease: clinical features and the role of vestibular evoked myogenic potentials.

    Science.gov (United States)

    Curthoys, Ian S; Manzari, Leonardo

    2013-07-01

    Through selective tests of the function of the canal and otolith sense organs, it is possible to assert that patient conditions are purely otolithic and that the canals are not involved. The video head impulse test selectively tests each semicircular canal; the ocular vestibular-evoked myogenic potential to 500 Hz Fz (Fz is the location on the forehead in the midline at the hairline) bone-conducted vibration (BCV) selectively tests the utricular macula and the cervical vestibular-evoked myogenic potential to 500 Hz Fz BCV selectively tests the saccular macula. The development of new specific tests of otolith function has shown that some patients may have specific deficits of just otolithic function. In the authors' experience, patients who complain strongly of postural unsteadiness should be suspected to have otolithic deficits. They may also have vertigo and in some cases have spontaneous nystagmus of peripheral origin, even though their semicircular canal function is normal. The prognosis for such patients is good. They usually appear to regain their postural stability spontaneously over weeks (or longer), even though they still have an otolithic deficit as shown by objective tests when they are free of symptoms. It is not known what procedures may accelerate the recovery of otolith function. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  3. [Turning the head, an unusual mechanism to compensate for diplopia caused by abduction restriction of one eye

    NARCIS (Netherlands)

    Kappelle, A.C.; Schelhaas, H.J.; Pasman, J.W.; Bloem, B.R.

    2004-01-01

    A 59-year-old-man visited the neurological outpatient clinic because of a leftward rotation of his head for the last 8 months. This head deviation turned out to represent a compensatory mechanism to alleviate diplopia that resulted from an abduction restriction of his left eye. By turning his head

  4. Restoration of three-dimensional MR images degraded by rotational movements

    International Nuclear Information System (INIS)

    Wood, M.L.

    1990-01-01

    This paper describes a method to restore three-dimensional (3D) magnetic resonance (MR) images that have been degraded by rotational movements, such as head nodding by a restless patient. The technique for acquiring the 3D MR images includes additional MR signals, which provide one-dimensional (1D) and two-dimensional (2D) projections of anatomy. The 1D projections detect gross movements, and the 2D projections resolve displacements in one plane. The 2D projections are transformed from Cartesian coordinates to polar coordinates to identify rotation. A spatial transformation to reverse the rotation is applied to the imaging data after they have been Fourier transformed to resolve structures in the plane of rotation, but before the Fourier transform for the third direction

  5. Task-specific modulation of human auditory evoked responses in a delayed-match-to-sample task

    Directory of Open Access Journals (Sweden)

    Feng eRong

    2011-05-01

    Full Text Available In this study, we focus our investigation on task-specific cognitive modulation of early cortical auditory processing in human cerebral cortex. During the experiments, we acquired whole-head magnetoencephalography (MEG data while participants were performing an auditory delayed-match-to-sample (DMS task and associated control tasks. Using a spatial filtering beamformer technique to simultaneously estimate multiple source activities inside the human brain, we observed a significant DMS-specific suppression of the auditory evoked response to the second stimulus in a sound pair, with the center of the effect being located in the vicinity of the left auditory cortex. For the right auditory cortex, a non-invariant suppression effect was observed in both DMS and control tasks. Furthermore, analysis of coherence revealed a beta band (12 ~ 20 Hz DMS-specific enhanced functional interaction between the sources in left auditory cortex and those in left inferior frontal gyrus, which has been shown to involve in short-term memory processing during the delay period of DMS task. Our findings support the view that early evoked cortical responses to incoming acoustic stimuli can be modulated by task-specific cognitive functions by means of frontal-temporal functional interactions.

  6. Design and control of the Twente humanoid head

    NARCIS (Netherlands)

    Visser, L.C.; Carloni, Raffaella; Stramigioli, Stefano

    2009-01-01

    The Twente humanoid head features a four degree of freedom neck and two eyes that are implemented by using cameras. The cameras tilt on a common axis, but can rotate sideways independently, thus implementing another three degrees of freedom. A vision processing algorithm has been developed that

  7. Light evokes melanopsin-dependent vocalization and neural activation associated with aversive experience in neonatal mice.

    Directory of Open Access Journals (Sweden)

    Anton Delwig

    Full Text Available Melanopsin-expressing intrinsically photosensitive retinal ganglion cells (ipRGCs are the only functional photoreceptive cells in the eye of newborn mice. Through postnatal day 9, in the absence of functional rods and cones, these ipRGCs mediate a robust avoidance behavior to a light source, termed negative phototaxis. To determine whether this behavior is associated with an aversive experience in neonatal mice, we characterized light-induced vocalizations and patterns of neuronal activation in regions of the brain involved in the processing of aversive and painful stimuli. Light evoked distinct melanopsin-dependent ultrasonic vocalizations identical to those emitted under stressful conditions, such as isolation from the litter. In contrast, light did not evoke the broad-spectrum calls elicited by acute mechanical pain. Using markers of neuronal activation, we found that light induced the immediate-early gene product Fos in the posterior thalamus, a brain region associated with the enhancement of responses to mechanical stimulation of the dura by light, and thought to be the basis for migrainous photophobia. Additionally, light induced the phosphorylation of extracellular-related kinase (pERK in neurons of the central amygdala, an intracellular signal associated with the processing of the aversive aspects of pain. However, light did not activate Fos expression in the spinal trigeminal nucleus caudalis, the primary receptive field for painful stimulation to the head. We conclude that these light-evoked vocalizations and the distinct pattern of brain activation in neonatal mice are consistent with a melanopsin-dependent neural pathway involved in processing light as an aversive but not acutely painful stimulus.

  8. Hydrodynamic interaction induced spontaneous rotation of coupled active filaments.

    Science.gov (United States)

    Jiang, Huijun; Hou, Zhonghuai

    2014-12-14

    We investigate the coupled dynamics of active filaments with long range hydrodynamic interactions (HI). Remarkably, we find that filaments can rotate spontaneously under the same conditions in which a single filament alone can only move in translation. Detailed analysis reveals that the emergence of coupled rotation originates from an asymmetric flow field associated with HI which breaks the symmetry of translational motion when filaments approach. The breaking is then further stabilized by HI to form self-sustained coupled rotation. Intensive simulations show that coupled rotation forms easily when one filament tends to collide with the front-half of the other. For head-to-tail approaching, we observe another interesting HI-induced coupled motion, where filaments move together in the form of one following the other. Moreover, the radius of coupled rotation increases exponentially as the rigidity of the filament increases, which suggests that HI are also important for the alignment of rigid-rod-like filaments which has been assumed to be solely a consequence of direct collisions.

  9. Skin denervation does not alter cortical potentials to surface concentric electrode stimulation: A comparison with laser evoked potentials and contact heat evoked potentials.

    Science.gov (United States)

    La Cesa, S; Di Stefano, G; Leone, C; Pepe, A; Galosi, E; Alu, F; Fasolino, A; Cruccu, G; Valeriani, M; Truini, A

    2018-01-01

    In the neurophysiological assessment of patients with neuropathic pain, laser evoked potentials (LEPs), contact heat evoked potentials (CHEPs) and the evoked potentials by the intraepidermal electrical stimulation via concentric needle electrode are widely agreed as nociceptive specific responses; conversely, the nociceptive specificity of evoked potentials by surface concentric electrode (SE-PREPs) is still debated. In this neurophysiological study we aimed at verifying the nociceptive specificity of SE-PREPs. We recorded LEPs, CHEPs and SE-PREPs in eleven healthy participants, before and after epidermal denervation produced by prolonged capsaicin application. We also used skin biopsy to verify the capsaicin-induced nociceptive nerve fibre loss in the epidermis. We found that whereas LEPs and CHEPs were suppressed after capsaicin-induced epidermal denervation, the surface concentric electrode stimulation of the same denervated skin area yielded unchanged SE-PREPs. The suppression of LEPs and CHEPs after nociceptive nerve fibre loss in the epidermis indicates that these techniques are selectively mediated by nociceptive system. Conversely, the lack of SE-PREP changes suggests that SE-PREPs do not provide selective information on nociceptive system function. Capsaicin-induced epidermal denervation abolishes laser evoked potentials (LEPs) and contact heat evoked potentials (CHEPs), but leaves unaffected pain-related evoked potentials by surface concentric electrode (SE-PREPs). These findings suggest that unlike LEPs and CHEPs, SE-PREPs are not selectively mediated by nociceptive system. © 2017 European Pain Federation - EFIC®.

  10. Spins of superdeformed rotational bands in Tl isotopes

    Energy Technology Data Exchange (ETDEWEB)

    Dadwal, Anshul; Mittal, H.M. [Dr. B.R. Ambedkar National Institute of Technology, Jalandhar (India)

    2017-01-15

    The two-parameter model defined for even-even nuclei viz. soft-rotor formula is used to assign the band-head spin of the 17 rotational bands in Tl isotopes. The least-squares fitting method is employed to obtain the spins of these bands in the A ∝ 190 mass region. The calculated transition energies are found to depend sensitively on the proposed spin. Whenever a correct spin assignment is made, the calculated and experimental transition energies coincide very well. The dynamic moment of inertia is also calculated and its variation with rotational frequency is explored. (orig.)

  11. Comparison of effectiveness between cork-screw and peg-screw electrodes for transcranial motor evoked potential monitoring using the finite element method.

    Science.gov (United States)

    Tomio, Ryosuke; Akiyama, Takenori; Ohira, Takayuki; Yoshida, Kazunari

    2016-01-01

    Intraoperative monitoring of motor evoked potentials by transcranial electric stimulation is popular in neurosurgery for monitoring motor function preservation. Some authors have reported that the peg-screw electrodes screwed into the skull can more effectively conduct current to the brain compared to subdermal cork-screw electrodes screwed into the skin. The aim of this study was to investigate the influence of electrode design on transcranial motor evoked potential monitoring. We estimated differences in effectiveness between the cork-screw electrode, peg-screw electrode, and cortical electrode to produce electric fields in the brain. We used the finite element method to visualize electric fields in the brain generated by transcranial electric stimulation using realistic three-dimensional head models developed from T1-weighted images. Surfaces from five layers of the head were separated as accurately as possible. We created the "cork-screws model," "1 peg-screw model," "peg-screws model," and "cortical electrode model". Electric fields in the brain radially diffused from the brain surface at a maximum just below the electrodes in coronal sections. The coronal sections and surface views of the brain showed higher electric field distributions under the peg-screw compared to the cork-screw. An extremely high electric field was observed under cortical electrodes. Our main finding was that the intensity of electric fields in the brain are higher in the peg-screw model than the cork-screw model.

  12. Closure head for a nuclear reactor

    International Nuclear Information System (INIS)

    Wade, E.E.

    1980-01-01

    A closure head for a nuclear reactor includes a stationary outer ring integral with the reactor vessel with a first rotatable plug disposed within the stationary outer ring and supported from the stationary outer ring by a bearing assembly. A sealing system is associated with the bearing assembly to seal the annulus defined between the first rotatable plug and the stationary outer ring. The sealing system comprises tubular seal elements disposed in the annulus with load springs contacting the tubular seal elements so as to force the tubular seal elements against the annulus in a manner to seal the annulus. The sealing system also comprises a sealing fluid which is pumped through the annulus and over the tubular seal elements causing the load springs to compress thereby reducing the friction between the tubular seal elements and the rotatable components while maintaining a gas-tight seal therebetween

  13. Brainstem Auditory Evoked Potential in HIV-Positive Adults.

    Science.gov (United States)

    Matas, Carla Gentile; Samelli, Alessandra Giannella; Angrisani, Rosanna Giaffredo; Magliaro, Fernanda Cristina Leite; Segurado, Aluísio C

    2015-10-20

    To characterize the findings of brainstem auditory evoked potential in HIV-positive individuals exposed and not exposed to antiretroviral treatment. This research was a cross-sectional, observational, and descriptive study. Forty-five HIV-positive individuals (18 not exposed and 27 exposed to the antiretroviral treatment - research groups I and II, respectively - and 30 control group individuals) were assessed through brainstem auditory evoked potential. There were no significant between-group differences regarding wave latencies. A higher percentage of altered brainstem auditory evoked potential was observed in the HIV-positive groups when compared to the control group. The most common alteration was in the low brainstem. HIV-positive individuals have a higher percentage of altered brainstem auditory evoked potential that suggests central auditory pathway impairment when compared to HIV-negative individuals. There was no significant difference between individuals exposed and not exposed to antiretroviral treatment.

  14. Prediction of mandibular rotation: an empirical test of clinician performance.

    Science.gov (United States)

    Baumrind, S; Korn, E L; West, E E

    1984-11-01

    An experiment was conducted in an attempt to determine empirically how effective a number of expert clinicians were at differentiating "backward rotators" from "forward rotators" on the basis of head-film information which might reasonably have been available to them prior to instituting treatment for the correction of Class II malocclusion. As a result of a previously reported ongoing study, pre- and posttreatment head films were available for 188 patients treated in the mixed dentition for the correction of Class II malocclusion and for 50 untreated Class II subjects. These subjects were divided into 14 groups (average size of group, 17; range, 6 to 23) solely on the basis of type of treatment and the clinician from whose clinic the records had originated. From within each group, we selected the two or three subjects who had exhibited the most extreme backward rotation and the two or three subjects who had exhibited the most extreme forward rotation of the mandible during the interval between films. The sole criterion for classification was magnitude of change in the mandibular plane angle of Downs between the pre- and posttreatment films of each patient. The resulting sample contained 32 backward-rotator subjects and 32 forward-rotator subjects. Five expert judges (mean clinical experience, 28 years) were asked to identify the backward-rotator subjects by examination of the pretreatment films. The findings may be summarized as follows: (1) No judge performed significantly better than chance. (2) There was strong evidence that the judges used a shared, though relatively ineffective, set of rules in making their discriminations between forward and backward rotators. (3) Statistical analysis of the predictive power of a set of standard cephalometric measurements which had previously been made for this set of subjects indicated that the numerical data also failed to identify potential backward rotators at a rate significantly better than chance. We infer from these

  15. Psychological and physiological responses to odor-evoked autobiographic memory.

    Science.gov (United States)

    Matsunaga, Masahiro; Isowa, Tokiko; Yamakawa, Kaori; Kawanishi, Yoko; Tsuboi, Hirohito; Kaneko, Hiroshi; Sadato, Norihiro; Oshida, Akiko; Katayama, Atsushi; Kashiwagi, Mitsuyoshi; Ohira, Hideki

    2011-01-01

    The "Proust phenomenon" occurs when a certain smell evokes a specific memory. Recent studies have demonstrated that odor-evoked autobiographic memories are more emotional than those elicited by other sensory stimuli because of the direct neural communication between the olfactory system and the amygdala. The amygdala is known to regulate various physiological activities including the endocrine and immune systems; therefore, odor-evoked autobiographic memory may trigger various psychological and physiological responses; however, the responses elicited by this memory remains obscure. In this study, we aimed to investigate the psychological and physiological responses accompanying odor-evoked autobiographic memory. We recruited healthy male and female volunteers and investigated changes in their mood states and autonomic nervous, endocrine, and immune activities when autobiographic memory was evoked in the participants by asking them to smell an odor(s) that was nostalgic to them. The autobiographic memories associated with positive emotion resulted in increased positive mood states, such as comfort and happiness, and decreased negative mood states, such as anxiety. Furthermore, heart rate was decreased, skin-conductance level was increased, and peripheral interleukin-2 level was decreased after smelling the nostalgic odor. These psychological and physiological responses were significantly correlated. The present study suggests that odor-evoked autobiographic memory along with a positive feeling induce various physiological responses, including the autonomic nervous and immune activities. To the best of our knowledge, the present study is the first to observe an interaction between odor-evoked autobiographic memories and immune function.

  16. Evoked acoustic emission

    DEFF Research Database (Denmark)

    Elberling, C; Parbo, J; Johnsen, N J

    1985-01-01

    Stimulated acoustic emissions were recorded in response to tonal stimuli at 60 dB p.e. SPL in a small group of normal-hearing adults. Power spectral analysis reveals that the evoked activity from each ear contains energy in preferential frequency bands and the change of stimulus frequency has only...

  17. The active abduction view: A new maneuvre in the diagnosis of rotator cuff tears

    International Nuclear Information System (INIS)

    Bloom, R.A.

    1991-01-01

    A new projection is described, the active abduction view of the shoulder, where in many patients with a comlete rotator cuff tear the humeral head is closely apposed to the acromion, obliterating the subacromial space. In such a situation,the medial portion of the torn rotator cuff retracts during active abduction, allowing approximation of the two bones. (orig./GDG)

  18. Risk Factors, Pathobiomechanics and Physical Examination of Rotator Cuff Tears

    Science.gov (United States)

    Moulton, Samuel G.; Greenspoon, Joshua A.; Millett, Peter J.; Petri, Maximilian

    2016-01-01

    Background: It is important to appreciate the risk factors for the development of rotator cuff tears and specific physical examination maneuvers. Methods: A selective literature search was performed. Results: Numerous well-designed studies have demonstrated that common risk factors include age, occupation, and anatomic considerations such as the critical shoulder angle. Recently, research has also reported a genetic component as well. The rotator cuff axially compresses the humeral head in the glenohumeral joint and provides rotational motion and abduction. Forces are grouped into coronal and axial force couples. Rotator cuff tears are thought to occur when the force couples become imbalanced. Conclusion: Physical examination is essential to determining whether a patient has an anterosuperior or posterosuperior tear. Diagnostic accuracy increases when combining a series of examination maneuvers. PMID:27708731

  19. Brainstem evoked potentials in infantile spasms

    International Nuclear Information System (INIS)

    Miyazaki, Masahito; Hashimoto, Toshiaki; Murakawa, Kazuyoshi; Tayama, Masanobu; Kuroda, Yasuhiro

    1992-01-01

    In ten patients with infantile spasms, brainstem evoked potentials and MRI examinations were performed to evaluate the brainstem involvement. The result of short latency somatosensory evoked potentials (SSEP) following the right median nerve stimulation revealed abnormal findings including the absence or low amplitudes of the waves below wave P3 and delayed central conduction time in 7 of the ten patients. The result of auditory brainstem responses (ABR) revealed abnormal findings including low amplitudes of wave V, prolonged interpeak latency of waves I-V and absence of the waves below wave IV in 5 of the ten patients. The result of the MRI examinations revealed various degrees of the brainstem atrophy in 6 of the ten patients, all of whom showed abnormal brainstem evoked potentials. The result of this study demonstrates that patients with infantile spasms are frequently associated with brainstem dysfunction and raises the possibility that brainstem atrophy might be a cause of infantile spasms. (author)

  20. [High-frequency rotation sensation function damage of the crista of the horizontal semicircular canal induced by gentamicin and its morphological basis.].

    Science.gov (United States)

    Chen, Liang; He, Ming; Wang, Wu-Qing

    2009-12-25

    The goal of the present study was to explore high-frequency rotation sensation function damage of the crista of the horizontal semicircular canal induced by gentamicin and its morphological basis. The guinea pigs were randomly divided into four groups (group 1, 2, 3 and control group, n=20). The animals of treated groups received gentamicin subcutaneously (50 mg/kg per day) for 1 week (group 1), 2 weeks (group 2) and 3 weeks (group 3), respectively. The animals of control group were administered with equal volume of saline subcutaneously. Videonystagmography (VNG) evoked by ice water or high-frequency rotations, and vestibular evoked potential (VsEP) evoked by low- and high-frequency rotations were recorded after the administration. After VNG and VsEP were examined, the cristae of the horizontal semicircular canals were prepared for scanning and transmission electron microscopy. The results are as follows: (1) In VNG examination, after ice water stimulation, no obvious nystagmus was observed in the animals of group 3, and there was no significant difference in nystagmus frequency and duration among group 1, 2 and control group (P>0.05). After high- frequency rotations, no obvious nystagmus was yet observed in the animals of group 3. There were significant differences in the nystagmus frequency and duration of the VNG waves between the experimental group 2 and control group (P0.05). (2) In VsEP examination, there was no significant difference in the parameters of VsEP among group 1, 2 and control group (P>0.05), and VsEP was not observed in group 3 after low-frequency rotations. After high- frequency rotations, compared with control group, the latencies and amplitudes of P1 and P2 in group 2 significantly decreased (P0.05). Group 3 had no response of VsEP to high-frequency rotations. (3) Electron microscopy was used to observe the crista hair cells of the four groups. In control group, the hair cells were normal. In group 1, almost normal appearance with slight

  1. Cylinder head fastening structure for internal combustion engines

    Energy Technology Data Exchange (ETDEWEB)

    Futakuchi, Y.; Oshiro, N.

    1988-01-26

    In a construction for an overhead cam internal combustion engine comprising a cylinder head adapted to be affixed to another component of the engine by at least one fastener having a tool receiving portion for tightening thereof and having a bearing cap affixed to the cylinder head and rotatably journaling the overhead camshaft, the improvement is described comprising the bearing cap having a portion overlying the fastener tool receiving portion, and means defining an access opening passing through the bearing cap and adapted to pass a tool for tightening of the fastener without removal of the bearing cap.

  2. Can visual evoked potentials be used in biometric identification?

    Science.gov (United States)

    Power, Alan J; Lalor, Edmund C; Reilly, Richard B

    2006-01-01

    Due to known differences in the anatomical structure of the visual pathways and generators in different individuals, the use of visual evoked potentials offers the possibility of an alternative to existing biometrics methods. A study based on visual evoked potentials from 13 individuals was carried out to assess the best combination of temporal, spectral and AR modeling features to realize a robust biometric. From the results it can be concluded that visual evoked potentials show considerable biometric qualities, with classification accuracies reaching a high of 86.54% and that a specific temporal and spectral combination was found to be optimal. Based on these results the visual evoked potential may be a useful tool in biometric identification when used in conjunction with more established biometric methods.

  3. Vergence-mediated changes in the axis of eye rotation during the human vestibulo-ocular reflex can occur independent of eye position.

    Science.gov (United States)

    Migliaccio, Americo A; Cremer, Phillip D; Aw, Swee T; Halmagyi, G Michael; Curthoys, Ian S; Minor, Lloyd B; Todd, Michael J

    2003-07-01

    The aim of this study was to determine whether vergence-mediated changes in the axis of eye rotation in the human vestibulo-ocular reflex (VOR) would obey Listing's Law (normally associated with saccadic eye movements) independent of the initial eye position. We devised a paradigm for disassociating the saccadic velocity axis from eye position by presenting near and far targets that were centered with respect to one eye. We measured binocular 3-dimensional eye movements using search coils in ten normal subjects and 3-dimensional linear head acceleration using Optotrak in seven normal subjects. The stimuli consisted of passive, unpredictable, pitch head rotations with peak acceleration of approximately 2000 degrees /s(2 )and amplitude of approximately 20 degrees. During the pitch head rotation, each subject fixated straight ahead with one eye, whereas the other eye was adducted 4 degrees during far viewing (94 cm) and 25 degrees during near viewing (15 cm). Our data showed expected compensatory pitch rotations in both eyes, and a vergence-mediated horizontal rotation only in the adducting eye. In addition, during near viewing we observed torsional eye rotations not only in the adducting eye but also in the eye looking straight ahead. In the straight-ahead eye, the change in torsional eye velocity between near and far viewing, which began approximately 40 ms after the start of head rotation, was 10+/-6 degrees /s (mean +/- SD). This change in torsional eye velocity resulted in a 2.4+/-1.5 degrees axis tilt toward Listing's plane in that eye. In the adducting eye, the change in torsional eye velocity between near and far viewing was 16+/-6 degrees /s (mean +/- SD) and resulted in a 4.1+/-1.4 degrees axis tilt. The torsional eye velocities were conjugate and both eyes partially obeyed Listing's Law. The axis of eye rotation tilted in the direction of the line of sight by approximately one-third of the angle between the line of sight and a line orthogonal to Listing

  4. Opening talk of Didier Houssin, head of the direction of raw materials and hydrocarbons. Talk of Gerard Piketty, head of CEP and M at the CEP and M-COPREP day of October 10, 2000, corresponding to the 50. anniversary of FSH. Talk of Gilbert Rutman head of COPREP; Discours d'ouverture de Didier Houssin Directeur des matieres premieres et des hydrocarbures. Allocation de Gerard Piketty, president du CEP and M a la journee CEP and M-COPREP du 10 octobre 2000, marquant par ailleurs le 50. anniversaire du FSH. Discours de Gilbert Rutman president du COPREP

    Energy Technology Data Exchange (ETDEWEB)

    Houssin, D; Piketty, G [Comite d' Etudes Petrolieres et Marines, 92 - Paris la Defense (France); Rutman, G [COPREP, (France)

    2000-07-01

    These articles report on the different opening talks of D. Housin, G. Piketty and G. Rutman. D. Houssin, head of the direction of raw materials and hydrocarbons, analyzes the main events of the petroleum industry for the year 2000 (oil crisis, oil prices, hydrocarbons market, para-petroleum sector etc..). G. Piketty, head of CEP and M, recalls some highlights of CEP and M's history, while G. Rutman, head of COPREP, briefly evokes the activities of his own technical committee. (J.S.)

  5. Opening talk of Didier Houssin, head of the direction of raw materials and hydrocarbons. Talk of Gerard Piketty, head of CEP and M at the CEP and M-COPREP day of October 10, 2000, corresponding to the 50. anniversary of FSH. Talk of Gilbert Rutman head of COPREP; Discours d'ouverture de Didier Houssin Directeur des matieres premieres et des hydrocarbures. Allocation de Gerard Piketty, president du CEP and M a la journee CEP and M-COPREP du 10 octobre 2000, marquant par ailleurs le 50. anniversaire du FSH. Discours de Gilbert Rutman president du COPREP

    Energy Technology Data Exchange (ETDEWEB)

    Houssin, D.; Piketty, G. [Comite d' Etudes Petrolieres et Marines, 92 - Paris la Defense (France); Rutman, G. [COPREP, (France)

    2000-07-01

    These articles report on the different opening talks of D. Housin, G. Piketty and G. Rutman. D. Houssin, head of the direction of raw materials and hydrocarbons, analyzes the main events of the petroleum industry for the year 2000 (oil crisis, oil prices, hydrocarbons market, para-petroleum sector etc..). G. Piketty, head of CEP and M, recalls some highlights of CEP and M's history, while G. Rutman, head of COPREP, briefly evokes the activities of his own technical committee. (J.S.)

  6. Emotion and affect in mental imagery: Do fear and anxiety manipulate mental rotation performance?

    Directory of Open Access Journals (Sweden)

    Sandra eKaltner

    2014-07-01

    Full Text Available Little is known about the effects of fear as a basic emotion on mental rotation performance. We expected that the emotional arousal evoked by fearful stimuli presented prior to each mental rotation trial would enhance mental rotation performance. Regarding the influence of anxiety, high anxious participants are supposed to show slower responses and higher error rates in this specific visuo-spatial ability. Furthermore, with respect to the embodied cognition viewpoint we wanted to investigate if the influence of fear on mental rotation performance is the same for egocentric and object-based transformations. Results show that fear enhances mental rotation performance, expressed by a higher mental rotation speed. Interestingly, this influence is stimulus-specific: it is restricted to egocentric transformations. Both observation of emotional stimuli and egocentric strategies are associated with left hemisphere activation which could explain a stronger influence on this type of transformation during observation. Another possible notion is the conceptual link between visuo-spatial perspective taking and empathy based on the co-activation of parietal areas. Stronger responses in egocentric transformations could result from this specific link. Regarding the influence of anxiety, participants with high scores on the trait-anxiety scale showed poor results in both reaction time and mental rotation speed. Findings of impoverished recruitment of prefrontal attentional control in patients with high scores in trait anxiety could be the explanation for this reduced performance.

  7. Cross-axis adaptation improves 3D vestibulo-ocular reflex alignment during chronic stimulation via a head-mounted multichannel vestibular prosthesis

    Science.gov (United States)

    Dai, Chenkai; Fridman, Gene Y.; Chiang, Bryce; Davidovics, Natan; Melvin, Thuy-Anh; Cullen, Kathleen E.; Della Santina, Charles C.

    2012-01-01

    By sensing three-dimensional (3D) head rotation and electrically stimulating the three ampullary branches of a vestibular nerve to encode head angular velocity, a multichannel vestibular prosthesis (MVP) can restore vestibular sensation to individuals disabled by loss of vestibular hair cell function. However, current spread to afferent fibers innervating non-targeted canals and otolith endorgans can distort the vestibular nerve activation pattern, causing misalignment between the perceived and actual axis of head rotation. We hypothesized that over time, central neural mechanisms can adapt to correct this misalignment. To test this, we rendered five chinchillas vestibular-deficient via bilateral gentamicin treatment and unilaterally implanted them with a head mounted MVP. Comparison of 3D angular vestibulo-ocular reflex (aVOR) responses during 2 Hz, 50°/s peak horizontal sinusoidal head rotations in darkness on the first, third and seventh days of continual MVP use revealed that eye responses about the intended axis remained stable (at about 70% of the normal gain) while misalignment improved significantly by the end of one week of prosthetic stimulation. A comparable time course of improvement was also observed for head rotations about the other two semicircular canal axes and at every stimulus frequency examined (0.2–5 Hz). In addition, the extent of disconjugacy between the two eyes progressively improved during the same time window. These results indicate that the central nervous system rapidly adapts to multichannel prosthetic vestibular stimulation to markedly improve 3D aVOR alignment within the first week after activation. Similar adaptive improvements are likely to occur in other species, including humans. PMID:21374081

  8. Binaural interaction in auditory evoked potentials: Brainstem, middle- and long-latency components

    OpenAIRE

    McPherson, DL; Starr, A

    1993-01-01

    Binaural interaction occurs in the auditory evoked potentials when the sum of the monaural auditory evoked potentials are not equivalent to the binaural evoked auditory potentials. Binaural interaction of the early- (0-10 ms), middle- (10-50 ms) and long-latency (50-200 ms) auditory evoked potentials was studied in 17 normal young adults. For the early components, binaural interaction was maximal at 7.35 ms accounting for a reduction of 21% of the amplitude of the binaural evoked potentials. ...

  9. Balanced Cluster Head Selection Based on Modified k-Means in a Distributed Wireless Sensor Network

    OpenAIRE

    Periyasamy, Sasikumar; Khara, Sibaram; Thangavelu, Shankar

    2016-01-01

    A major problem with Wireless Sensor Networks (WSNs) is the maximization of effective network lifetime through minimization of energy usage in the network nodes. A modified k-means (Mk-means) algorithm for clustering was proposed which includes three cluster heads (simultaneously chosen) for each cluster. These cluster heads (CHs) use a load sharing mechanism to rotate as the active cluster head, which conserves residual energy of the nodes, thereby extending network lifetime. Moreover, it re...

  10. Head movements encode emotions during speech and song.

    Science.gov (United States)

    Livingstone, Steven R; Palmer, Caroline

    2016-04-01

    When speaking or singing, vocalists often move their heads in an expressive fashion, yet the influence of emotion on vocalists' head motion is unknown. Using a comparative speech/song task, we examined whether vocalists' intended emotions influence head movements and whether those movements influence the perceived emotion. In Experiment 1, vocalists were recorded with motion capture while speaking and singing each statement with different emotional intentions (very happy, happy, neutral, sad, very sad). Functional data analyses showed that head movements differed in translational and rotational displacement across emotional intentions, yet were similar across speech and song, transcending differences in F0 (varied freely in speech, fixed in song) and lexical variability. Head motion specific to emotional state occurred before and after vocalizations, as well as during sound production, confirming that some aspects of movement were not simply a by-product of sound production. In Experiment 2, observers accurately identified vocalists' intended emotion on the basis of silent, face-occluded videos of head movements during speech and song. These results provide the first evidence that head movements encode a vocalist's emotional intent and that observers decode emotional information from these movements. We discuss implications for models of head motion during vocalizations and applied outcomes in social robotics and automated emotion recognition. (c) 2016 APA, all rights reserved).

  11. Elevating Endogenous GABA Levels with GAT-1 Blockade Modulates Evoked but Not Induced Responses in Human Visual Cortex

    Science.gov (United States)

    Muthukumaraswamy, Suresh D; Myers, Jim F M; Wilson, Sue J; Nutt, David J; Hamandi, Khalid; Lingford-Hughes, Anne; Singh, Krish D

    2013-01-01

    The electroencephalographic/magnetoencephalographic (EEG/MEG) signal is generated primarily by the summation of the postsynaptic currents of cortical principal cells. At a microcircuit level, these glutamatergic principal cells are reciprocally connected to GABAergic interneurons. Here we investigated the relative sensitivity of visual evoked and induced responses to altered levels of endogenous GABAergic inhibition. To do this, we pharmacologically manipulated the GABA system using tiagabine, which blocks the synaptic GABA transporter 1, and so increases endogenous GABA levels. In a single-blinded and placebo-controlled crossover study of 15 healthy participants, we administered either 15 mg of tiagabine or a placebo. We recorded whole-head MEG, while participants viewed a visual grating stimulus, before, 1, 3 and 5 h post tiagabine ingestion. Using beamformer source localization, we reconstructed responses from early visual cortices. Our results showed no change in either stimulus-induced gamma-band amplitude increases or stimulus-induced alpha amplitude decreases. However, the same data showed a 45% reduction in the evoked response component at ∼80 ms. These data demonstrate that, in early visual cortex the evoked response shows a greater sensitivity compared with induced oscillations to pharmacologically increased endogenous GABA levels. We suggest that previous studies correlating GABA concentrations as measured by magnetic resonance spectroscopy to gamma oscillation frequency may reflect underlying variations such as interneuron/inhibitory synapse density rather than functional synaptic GABA concentrations. PMID:23361120

  12. Posterior-only spinal fusion without rib head resection for treating type I neurofibromatosis with intra-canal rib head dislocation

    Directory of Open Access Journals (Sweden)

    Dong Sun

    2013-12-01

    Full Text Available OBJECTIVES: Patients with Type I neurofibromatosis scoliosis with intra-canal rib head protrusion are extremely rare. Current knowledge regarding the diagnosis and treatment for this situation are insufficient. The purpose of this study is to share our experience in the diagnosis and surgical treatments for such unique deformities. METHODS: Six patients with Type I neurofibromatosis scoliosis with rib head dislocation into the spinal canal were diagnosed at our institution. Posterior instrumentation and spinal fusion without intra-canal rib head resection via a posterior-only approach was performed for deformity correction and rib head extraction. The efficacy and outcomes of the surgery were evaluated by measurements before, immediately and 24 months after the surgery using the following parameters: coronal spinal Cobb angle, apex rotation and kyphosis of the spine and the intra-canal rib head position. Post-operative complications, surgery time and blood loss were also evaluated. RESULTS: Patients were followed up for at least 24 months post-operatively. The three dimensional spinal deformity was significantly improved and the intra-canal rib head was significantly extracted from the canal immediately after the surgery. At follow-up 24 months after surgery, solid fusions were achieved along the fusion segments, and the deformity corrections and rib head positions were well maintained. There were no surgery-related complications any time after the surgery. CONCLUSIONS: Systematic examinations are needed to identify patients with Type I neurofibromatosis scoliosis with rib head dislocation into the canal who can be treated by posterior-only spinal fusion without rib head resection.

  13. Mild head injury and attention deficit hyperactivity disorder in children.

    Science.gov (United States)

    Chasle, Veronique; Riffaud, Laurent; Longuet, Romain; Martineau-Curt, Marie; Collet, Yann; Le Fournier, Luc; Pladys, Patrick

    2016-12-01

    Post-concussion syndrome is a well-described complication following moderate and severe head trauma but whether it occurs after mild head injury in children remains unclear. The aim of this study was to evaluate whether exposure to mild head injury with potential additional risk factors (non-surgical lesion on computed tomographic, high kinetic trauma, or Glasgow Coma Scale <15) is associated with attention deficit hyperactivity disorder (ADHD) after the head trauma. This study was performed in an emergency department on children admitted between 2009 and 2013. It compared victims of mild head injury aged 6-16 years with matched children presenting isolated non-surgical forearm fracture (ratio1/2). ADHD was assessed using Conners' Global Index-Parent short version 3-40 months after the trauma. The patients were compared using chi-square test or Fisher's exact test, t test or u-test as appropriate with a p value set at 0.05. During the study period, 676 patients were admitted for mild head injury. Among them, 34 (5 %) fulfilled the inclusion criteria and were compared with 64 matched patients admitted for a forearm fracture. The groups were comparable. ADHD was observed in both groups (18 % in the mild head injury group, 11 % in the control group) with no significant differences between groups. The prevalence was high when compared to an expected frequency of 3.5-5.6 % in children aged 6-12 years in the general population. These results suggest that pre-existing ADHD may have contributed to injury proneness in both groups and does not argue for a specific risk of ADHD induced by mild head injury. The diagnosis of ADHD should be evoked at admission of children aged 6-16 years presenting with a trauma.

  14. Supervisory Rotation: Impact on an Academic Library Reference Staff.

    Science.gov (United States)

    Perdue, Bob; Piotrowski, Chris

    The results of a managerial rotation program in a medium-sized academic library reference department are presented. After meeting certain minimal eligibility requirements, librarians in this department take turns on a 2-year cycle serving as head of the department. This case study is used as a model to assess both the advantages and disadvantages…

  15. Slow cortical evoked potentials after noise exposure

    Energy Technology Data Exchange (ETDEWEB)

    von Wedel, H; Opitz, H J

    1979-07-01

    Human cortical evoked potentials under conditions of stimuation are registrated in the post-stimulatory phase of a five minutes lasting equally masking white noise (90 dB HL). Changes of the evoked potentials during adaptation, possible analogy with high tone losses after noise representation and the origin of tinnitus are examined. Stimulation was started 3 sec after the off-effect of the noise. For five minutes periodically tone bursts were represented. Each train of stimulation consists of tone bursts of three frequencies: 2 kcs, 4 kcs, 8 kcs. The 0.5 sec lasting tones were separated by pauses of 2 sec. During the experiment stimulation and analysis were controlled by a computer. Changes in latency and amplitudes of the cortical evoked potentials were registered. Changes of the adaptation patterns as a function of the poststimulatory time are discussed.

  16. Regenerative Medicine in Rotator Cuff Injuries

    Science.gov (United States)

    Randelli, Pietro; Ragone, Vincenza; Menon, Alessandra; Cabitza, Paolo; Banfi, Giuseppe

    2014-01-01

    Rotator cuff injuries are a common source of shoulder pathology and result in an important decrease in quality of patient life. Given the frequency of these injuries, as well as the relatively poor result of surgical intervention, it is not surprising that new and innovative strategies like tissue engineering have become more appealing. Tissue-engineering strategies involve the use of cells and/or bioactive factors to promote tendon regeneration via natural processes. The ability of numerous growth factors to affect tendon healing has been extensively analyzed in vitro and in animal models, showing promising results. Platelet-rich plasma (PRP) is a whole blood fraction which contains several growth factors. Controlled clinical studies using different autologous PRP formulations have provided controversial results. However, favourable structural healing rates have been observed for surgical repair of small and medium rotator cuff tears. Cell-based approaches have also been suggested to enhance tendon healing. Bone marrow is a well known source of mesenchymal stem cells (MSCs). Recently, ex vivo human studies have isolated and cultured distinct populations of MSCs from rotator cuff tendons, long head of the biceps tendon, subacromial bursa, and glenohumeral synovia. Stem cells therapies represent a novel frontier in the management of rotator cuff disease that required further basic and clinical research. PMID:25184132

  17. Regenerative Medicine in Rotator Cuff Injuries

    Directory of Open Access Journals (Sweden)

    Pietro Randelli

    2014-01-01

    Full Text Available Rotator cuff injuries are a common source of shoulder pathology and result in an important decrease in quality of patient life. Given the frequency of these injuries, as well as the relatively poor result of surgical intervention, it is not surprising that new and innovative strategies like tissue engineering have become more appealing. Tissue-engineering strategies involve the use of cells and/or bioactive factors to promote tendon regeneration via natural processes. The ability of numerous growth factors to affect tendon healing has been extensively analyzed in vitro and in animal models, showing promising results. Platelet-rich plasma (PRP is a whole blood fraction which contains several growth factors. Controlled clinical studies using different autologous PRP formulations have provided controversial results. However, favourable structural healing rates have been observed for surgical repair of small and medium rotator cuff tears. Cell-based approaches have also been suggested to enhance tendon healing. Bone marrow is a well known source of mesenchymal stem cells (MSCs. Recently, ex vivo human studies have isolated and cultured distinct populations of MSCs from rotator cuff tendons, long head of the biceps tendon, subacromial bursa, and glenohumeral synovia. Stem cells therapies represent a novel frontier in the management of rotator cuff disease that required further basic and clinical research.

  18. The Paradox of Music-Evoked Sadness: An Online Survey

    Science.gov (United States)

    Taruffi, Liila; Koelsch, Stefan

    2014-01-01

    This study explores listeners’ experience of music-evoked sadness. Sadness is typically assumed to be undesirable and is therefore usually avoided in everyday life. Yet the question remains: Why do people seek and appreciate sadness in music? We present findings from an online survey with both Western and Eastern participants (N = 772). The survey investigates the rewarding aspects of music-evoked sadness, as well as the relative contribution of listener characteristics and situational factors to the appreciation of sad music. The survey also examines the different principles through which sadness is evoked by music, and their interaction with personality traits. Results show 4 different rewards of music-evoked sadness: reward of imagination, emotion regulation, empathy, and no “real-life” implications. Moreover, appreciation of sad music follows a mood-congruent fashion and is greater among individuals with high empathy and low emotional stability. Surprisingly, nostalgia rather than sadness is the most frequent emotion evoked by sad music. Correspondingly, memory was rated as the most important principle through which sadness is evoked. Finally, the trait empathy contributes to the evocation of sadness via contagion, appraisal, and by engaging social functions. The present findings indicate that emotional responses to sad music are multifaceted, are modulated by empathy, and are linked with a multidimensional experience of pleasure. These results were corroborated by a follow-up survey on happy music, which indicated differences between the emotional experiences resulting from listening to sad versus happy music. This is the first comprehensive survey of music-evoked sadness, revealing that listening to sad music can lead to beneficial emotional effects such as regulation of negative emotion and mood as well as consolation. Such beneficial emotional effects constitute the prime motivations for engaging with sad music in everyday life. PMID:25330315

  19. The paradox of music-evoked sadness: an online survey.

    Directory of Open Access Journals (Sweden)

    Liila Taruffi

    Full Text Available This study explores listeners' experience of music-evoked sadness. Sadness is typically assumed to be undesirable and is therefore usually avoided in everyday life. Yet the question remains: Why do people seek and appreciate sadness in music? We present findings from an online survey with both Western and Eastern participants (N = 772. The survey investigates the rewarding aspects of music-evoked sadness, as well as the relative contribution of listener characteristics and situational factors to the appreciation of sad music. The survey also examines the different principles through which sadness is evoked by music, and their interaction with personality traits. Results show 4 different rewards of music-evoked sadness: reward of imagination, emotion regulation, empathy, and no "real-life" implications. Moreover, appreciation of sad music follows a mood-congruent fashion and is greater among individuals with high empathy and low emotional stability. Surprisingly, nostalgia rather than sadness is the most frequent emotion evoked by sad music. Correspondingly, memory was rated as the most important principle through which sadness is evoked. Finally, the trait empathy contributes to the evocation of sadness via contagion, appraisal, and by engaging social functions. The present findings indicate that emotional responses to sad music are multifaceted, are modulated by empathy, and are linked with a multidimensional experience of pleasure. These results were corroborated by a follow-up survey on happy music, which indicated differences between the emotional experiences resulting from listening to sad versus happy music. This is the first comprehensive survey of music-evoked sadness, revealing that listening to sad music can lead to beneficial emotional effects such as regulation of negative emotion and mood as well as consolation. Such beneficial emotional effects constitute the prime motivations for engaging with sad music in everyday life.

  20. The paradox of music-evoked sadness: an online survey.

    Science.gov (United States)

    Taruffi, Liila; Koelsch, Stefan

    2014-01-01

    This study explores listeners' experience of music-evoked sadness. Sadness is typically assumed to be undesirable and is therefore usually avoided in everyday life. Yet the question remains: Why do people seek and appreciate sadness in music? We present findings from an online survey with both Western and Eastern participants (N = 772). The survey investigates the rewarding aspects of music-evoked sadness, as well as the relative contribution of listener characteristics and situational factors to the appreciation of sad music. The survey also examines the different principles through which sadness is evoked by music, and their interaction with personality traits. Results show 4 different rewards of music-evoked sadness: reward of imagination, emotion regulation, empathy, and no "real-life" implications. Moreover, appreciation of sad music follows a mood-congruent fashion and is greater among individuals with high empathy and low emotional stability. Surprisingly, nostalgia rather than sadness is the most frequent emotion evoked by sad music. Correspondingly, memory was rated as the most important principle through which sadness is evoked. Finally, the trait empathy contributes to the evocation of sadness via contagion, appraisal, and by engaging social functions. The present findings indicate that emotional responses to sad music are multifaceted, are modulated by empathy, and are linked with a multidimensional experience of pleasure. These results were corroborated by a follow-up survey on happy music, which indicated differences between the emotional experiences resulting from listening to sad versus happy music. This is the first comprehensive survey of music-evoked sadness, revealing that listening to sad music can lead to beneficial emotional effects such as regulation of negative emotion and mood as well as consolation. Such beneficial emotional effects constitute the prime motivations for engaging with sad music in everyday life.

  1. Whiplash evokes descending muscle recruitment and sympathetic responses characteristic of startle

    Science.gov (United States)

    Mang, Daniel WH; Siegmund, Gunter P; Blouin, Jean-Sébastien

    2014-01-01

    Whiplash injuries are the most common injuries following rear-end collisions. During a rear-end collision, the human muscle response consists of both a postural and a startle response that may exacerbate injury. However, most previous studies only assessed the presence of startle using data collected from the neck muscles and head/neck kinematics. The startle response also evokes a descending pattern of muscle recruitment and changes in autonomic activity. Here we examined the recruitment of axial and appendicular muscles along with autonomic responses to confirm whether these other features of a startle response were present during the first exposure to a whiplash perturbation. Ten subjects experienced a single whiplash perturbation while recording electromyography, electrocardiogram, and electrodermal responses. All subjects exhibited a descending pattern of muscle recruitment, and increasing heart rate and electrodermal responses following the collision. Our results provide further support that the startle response is a component of the response to whiplash collisions. PMID:24932015

  2. Mixing by rotary jet heads: Indications of the benefits of head rotation under turbulent and transitional flow conditions

    DEFF Research Database (Denmark)

    Nordkvist, Mikkel; Vognsen, Marie; Nienow, Alfred W.

    2008-01-01

    Mixing times were obtained by the iodine-thiosulphate decolorization technique using rotary jet heads (RJH) for mixing in a Perspex tank with an inner diameter of 0.75 m and an aspect ratio of 2.5 using both water (turbulent flow) and shear-thinning, carboxymethyl cellulose (CMC) solutions...

  3. Head impacts in a junior rugby league team measured with a wireless head impact sensor: an exploratory analysis.

    Science.gov (United States)

    King, Doug; Hume, Patria; Gissane, Conor; Clark, Trevor

    2017-01-01

    OBJECTIVE The aim of this study was to investigate the frequency, magnitude, and distribution of head impacts sustained by players in a junior rugby league over a season of matches. METHODS The authors performed a prospective cohort analysis of impact magnitude, frequency, and distribution on data collected with instrumented XPatches worn behind the ear of players in an "under-11" junior rugby league team (players under 11 years old). RESULTS A total of 1977 impacts were recorded. Over the course of the study, players sustained an average of 116 impacts (average of 13 impacts per player per match). The measured linear acceleration ranged from 10g to 123g (mean 22g, median 16g, and 95th percentile 57g). The rotational acceleration ranged from 89 rad/sec 2 to 22,928 rad/sec 2 (mean 4041 rad/sec 2 , median 2773 rad/sec 2 , and 95th percentile 11,384 rad/sec 2 ). CONCLUSIONS The level of impact severity based on the magnitude of impacts for linear and rotational accelerations recorded was similar to the impacts reported in studies of American junior and high school football, collegiate football, and youth ice hockey players, but the players in the rugby league cohort were younger, had less body mass, and played at a slower speed than the American players. Junior rugby league players are required to tackle the player to the ground and use a different tackle technique than that used in American football, likely increasing the rotational accelerations recorded at the head.

  4. Genetic influence demonstrated for MEG-recorded somatosensory evoked responses

    NARCIS (Netherlands)

    van 't Ent, D.; van Soelen, I.L.C.; Stam, K.J.; de Geus, E.J.C.; Boomsma, D.I.

    2010-01-01

    We tested for a genetic influence on magnetoencephalogram (MEG)-recorded somatosensory evoked fields (SEFs) in 20 monozygotic (MZ) and 14 dizygotic (DZ) twin pairs. Previous electroencephalogram (EEG) studies that demonstrated a genetic contribution to evoked responses generally focused on

  5. Band head spin assignment of superdeformed bands in 133Pr using two-parameter formulae

    Science.gov (United States)

    Sharma, Honey; Mittal, H. M.

    2018-03-01

    The two-parameter formulae viz. the power index formula, the nuclear softness formula and the VMI model are adopted to accredit the band head spin (I0) of four superdeformed rotational bands in 133Pr. The technique of least square fitting is used to accredit the band head spin for four superdeformed rotational bands in 133Pr. The root mean deviation among the computed transition energies and well-known experimental transition energies are attained by extracting the model parameters from the two-parameter formulae. The determined transition energies are in excellent agreement with the experimental transition energies, whenever exact spins are accredited. The power index formula coincides well with the experimental data and provides minimum root mean deviation. So, the power index formula is more efficient tool than the nuclear softness formula and the VMI model. The deviation of dynamic moment of inertia J(2) against the rotational frequency is also examined.

  6. Visually Evoked Spiking Evolves While Spontaneous Ongoing Dynamics Persist

    DEFF Research Database (Denmark)

    Huys, Raoul; Jirsa, Viktor K; Darokhan, Ziauddin

    2016-01-01

    attractor. Its existence guarantees that evoked spiking return to the spontaneous state. However, the spontaneous ongoing spiking state and the visual evoked spiking states are qualitatively different and are separated by a threshold (separatrix). The functional advantage of this organization...

  7. Defensive peripersonal space: the blink reflex evoked by hand stimulation is increased when the hand is near the face.

    Science.gov (United States)

    Sambo, C F; Liang, M; Cruccu, G; Iannetti, G D

    2012-02-01

    Electrical stimulation of the median nerve at the wrist may elicit a blink reflex [hand blink reflex (HBR)] mediated by a neural circuit at brain stem level. As, in a Sherringtonian sense, the blink reflex is a defensive response, in a series of experiments we tested, in healthy volunteers, whether and how the HBR is modulated by the proximity of the stimulated hand to the face. Electromyographic activity was recorded from the orbicularis oculi, bilaterally. We observed that the HBR is enhanced when the stimulated hand is inside the peripersonal space of the face, compared with when it is outside, irrespective of whether the proximity of the hand to the face is manipulated by changing the position of the arm (experiment 1) or by rotating the head while keeping the arm position constant (experiment 3). Experiment 2 showed that such HBR enhancement has similar magnitude when the participants have their eyes closed. Experiments 4 and 5 showed, respectively, that the blink reflex elicited by the electrical stimulation of the supraorbital nerve, as well as the N20 wave of the somatosensory evoked potentials elicited by the median nerve stimulation, are entirely unaffected by hand position. Taken together, our results provide compelling evidence that the brain stem circuits mediating the HBR in humans undergo tonic and selective top-down modulation from higher order cortical areas responsible for encoding the location of somatosensory stimuli in external space coordinates. These findings support the existence of a "defensive" peripersonal space, representing a safety margin advantageous for survival.

  8. Energy Threshold-based Cluster Head Rotation for Routing Protocol in Wireless Sensor Networks

    Directory of Open Access Journals (Sweden)

    Hadi Raheem Ali

    2018-05-01

    Full Text Available Energy efficiency represents a fundamental issue in WSNs, since the network lifetime period entirely depends on the energy of sensor nodes, which are usually battery-operated. In this article, an unequal clustering-based routing protocol has been suggested, where parameters of energy, distance, and density are involved in the cluster head election. Besides, the sizes of clusters are unequal according to distance, energy, and density. Furthermore, the cluster heads are not changed every round unless the residual energy reaches a specific threshold of energy. The outcomes of the conducted simulation confirmed that the performance of the suggested protocol achieves improvement in energy efficiency.

  9. Joint angle affects volitional and magnetically-evoked neuromuscular performance differentially.

    Science.gov (United States)

    Minshull, C; Rees, D; Gleeson, N P

    2011-08-01

    This study examined the volitional and magnetically-evoked neuromuscular performance of the quadriceps femoris at functional knee joint angles adjacent to full extension. Indices of volitional and magnetically-evoked neuromuscular performance (N=15 healthy males, 23.5 ± 2.9 years, 71.5 ± 5.4 kg, 176.5 ± 5.5 cm) were obtained at 25°, 35° and 45° of knee flexion. Results showed that volitional and magnetically-evoked peak force (PF(V) and P(T)F(E), respectively) and electromechanical delay (EMD(V) and EMD(E), respectively) were enhanced by increased knee flexion. However, greater relative improvements in volitional compared to evoked indices of neuromuscular performance were observed with increasing flexion from 25° to 45° (e.g. EMD(V), EMD(E): 36% vs. 11% improvement, respectively; F([2,14])=6.8, pjoint positions. These findings suggest that the extent of the relative differential between volitional and evoked neuromuscular performance capabilities is joint angle-specific and not correlated with performance capabilities at adjacent angles, but tends to be smaller with increased flexion. As such, effective prediction of volitional from evoked performance capabilities at both analogous and adjacent knee joint positions would lack robustness. Copyright © 2011 Elsevier Ltd. All rights reserved.

  10. International Evoked Potentials Symposium

    CERN Document Server

    1980-01-01

    The past decade has seen great progress in the measurement of evoked potentials in man; a steady increase in our understanding of their charac­ teristics, their origins and their usefulness; and a growing application in the field of clinical diagnosis. The topic is a truly multidisciplinary one. Important research contributions have been made by workers of many different backgrounds and clinical applications span the specialities. This book represents a revised and updated version of the work originally presented at the international evoked potential symposium held in Nottingham 4-6 1978. The Nottingham Symposium provided a forum for a state-of-the-art discussion amongst workers from many different disciplines and from many different countries. For each major topic in the field an expert review set the scene for discussion of current research presentations. This format is retained in the book: the chapters in Part A provide the context in which the research presented in Part B is set. The task of selecting m...

  11. GyroVR: Simulating Inertia in Virtual Reality using Head Worn Flywheels

    DEFF Research Database (Denmark)

    Gugenheimer, Jan; Wolf, Dennis; Eiríksson, Eyþór Rúnar

    2016-01-01

    We present GyroVR, head worn flywheels designed to render inertia in Virtual Reality (VR. Motions such as flying, diving or floating in outer space generate kinesthetic forces onto our body which impede movement and are currently not represented in VR. We simulate those kinesthetic forces...... by attaching flywheels to the users head, leveraging the gyroscopic effect of resistance when changing the spinning axis of rotation. GyroVR is an ungrounded, wireless and self contained device allowing the user to freely move inside the virtual environment. The generic shape allows to attach it to different...... positions on the users body. We evaluated the impact of GyroVR onto different mounting positions on the head (back and front) in terms of immersion, enjoyment and simulator sickness. Our results show, that attaching GyroVR onto the users head (front of the Head Mounted Display (HMD)) resulted in the highest...

  12. Analysis of head impacts during sub-elite hurling practice sessions.

    Science.gov (United States)

    O'Sullivan, D; Roe, M; Blake, C

    2018-06-01

    The reported incidence of head and neck injuries in hurling is 0.12 per 1000 hours, but no previous research has quantified head impact characteristics in this sport. Here, a wireless accelerometer and gyroscope captured head impacts, in 20 senior club level hurling players. Peak linear and rotational acceleration and impact location were recorded during three hurling training sessions, each player participating once. A mean of 27.9 impacts (linear acceleration >10g) per player, per session were recorded; 1314 impacts during a total exposure time of 247 minutes. Only 2.6% impacts had peak linear acceleration of >70g and 6.2% had peak rotational acceleration >7900 rad/s 2 . There were significant differences in the number and magnitude of impacts, quantified by the accelerometer, between three training sessions of differing intensity (ŋ2 0.03-0.09, p impacts during hurling, demonstrating the feasibility of this technology in the field. The sensors were able to discriminate between sessions of varying intensity. These data can be used to develop athlete monitoring protocols and may be useful in developing innovative helmet-testing standards for hurling. The potential for this technology to provide feedback has clinical utility for team medical personnel.

  13. Head movement during CT brain perfusion acquisition of patients with suspected acute ischemic stroke

    International Nuclear Information System (INIS)

    Fahmi, F.; Beenen, L.F.M.; Streekstra, G.J.; Janssen, N.Y.; Jong, H.W. de; Riordan, A.; Roos, Y.B.; Majoie, C.B.; Bavel, E. van; Marquering, H.A.

    2013-01-01

    Objective: Computed Tomography Perfusion (CTP) is a promising tool to support treatment decision for acute ischemic stroke patients. However, head movement during acquisition may limit its applicability. Information of the extent of head motion is currently lacking. Our purpose is to qualitatively and quantitatively assess the extent of head movement during acquisition. Methods: From 103 consecutive patients admitted with suspicion of acute ischemic stroke, head movement in 220 CTP datasets was qualitatively categorized by experts as none, minimal, moderate, or severe. The movement was quantified using 3D registration of CTP volume data with non-contrast CT of the same patient; yielding 6 movement parameters for each time frame. The movement categorization was correlated with National Institutes of Health Stroke Scale (NIHSS) score and baseline characteristic using multinomial logistic regression and student's t-test respectively. Results: Moderate and severe head movement occurred in almost 25% (25/103) of all patients with acute ischemic stroke. The registration technique quantified head movement with mean rotation angle up to 3.6° and 14°, and mean translation up to 9.1 mm and 22.6 mm for datasets classified as moderate and severe respectively. The rotation was predominantly in the axial plane (yaw) and the main translation was in the scan direction. There was no statistically significant association between movement classification and NIHSS score and baseline characteristics. Conclusions: Moderate or severe head movement during CTP acquisition of acute stroke patients is quite common. The presented registration technique can be used to automatically quantify the movement during acquisition, which can assist identification of CTP datasets with excessive head movement

  14. Head movement during CT brain perfusion acquisition of patients with suspected acute ischemic stroke

    Energy Technology Data Exchange (ETDEWEB)

    Fahmi, F., E-mail: f.fahmi@amc.uva.nl [Department of Biomedical Engineering and Physics, AMC, Amsterdam (Netherlands); Beenen, L.F.M., E-mail: l.f.beenen@amc.uva.nl [Department of Radiology, AMC, Amsterdam (Netherlands); Streekstra, G.J., E-mail: g.j.streekstra@amc.uva.nl [Department of Biomedical Engineering and Physics, AMC, Amsterdam (Netherlands); Janssen, N.Y., E-mail: n.n.janssen@amc.uva.nl [Department of Biomedical Engineering and Physics, AMC, Amsterdam (Netherlands); Jong, H.W. de, E-mail: H.W.A.M.deJong@umcutrecht.nl [Department of Radiology, UMC Utrecht, 3584CX, Utrecht (Netherlands); Riordan, A., E-mail: alan.riordan@gmail.com [Department of Radiology, UMC Utrecht, 3584CX, Utrecht (Netherlands); Roos, Y.B., E-mail: y.b.roos@amc.uva.nl [Department of Neurology, AMC, Amsterdam (Netherlands); Majoie, C.B., E-mail: c.b.majoie@amc.uva.nl [Department of Radiology, AMC, Amsterdam (Netherlands); Bavel, E. van, E-mail: e.vanbavel@amc.uva.nl [Department of Biomedical Engineering and Physics, AMC, Amsterdam (Netherlands); Marquering, H.A., E-mail: h.a.marquering@amc.uva.nl [Department of Biomedical Engineering and Physics, AMC, Amsterdam (Netherlands); Department of Radiology, AMC, Amsterdam (Netherlands)

    2013-12-01

    Objective: Computed Tomography Perfusion (CTP) is a promising tool to support treatment decision for acute ischemic stroke patients. However, head movement during acquisition may limit its applicability. Information of the extent of head motion is currently lacking. Our purpose is to qualitatively and quantitatively assess the extent of head movement during acquisition. Methods: From 103 consecutive patients admitted with suspicion of acute ischemic stroke, head movement in 220 CTP datasets was qualitatively categorized by experts as none, minimal, moderate, or severe. The movement was quantified using 3D registration of CTP volume data with non-contrast CT of the same patient; yielding 6 movement parameters for each time frame. The movement categorization was correlated with National Institutes of Health Stroke Scale (NIHSS) score and baseline characteristic using multinomial logistic regression and student's t-test respectively. Results: Moderate and severe head movement occurred in almost 25% (25/103) of all patients with acute ischemic stroke. The registration technique quantified head movement with mean rotation angle up to 3.6° and 14°, and mean translation up to 9.1 mm and 22.6 mm for datasets classified as moderate and severe respectively. The rotation was predominantly in the axial plane (yaw) and the main translation was in the scan direction. There was no statistically significant association between movement classification and NIHSS score and baseline characteristics. Conclusions: Moderate or severe head movement during CTP acquisition of acute stroke patients is quite common. The presented registration technique can be used to automatically quantify the movement during acquisition, which can assist identification of CTP datasets with excessive head movement.

  15. SU-E-T-521: Feasibility Study of a Rotational Step-And-Shoot IMRT Treatment Planning Approach

    International Nuclear Information System (INIS)

    Zhu, X; Chang, S; Cullip, T; Yuan, L; Zhang, X; Lian, J; Tang, X; Tracton, G; Dooley, J

    2014-01-01

    Purpose: Rotational step-and-shot IMRT (r-IMRT) could improve delivery efficiency with good dose conformity, especially if it can leverage the burst mode of the accelerator where radiation is turned on/off momentarily while the gantry rotates continuously. The challenge for the r-IMRT planning is to minimize the number of beams to achieve a fast and smooth rotational delivery. Methods: Treatment plans for r-IMRT were created using an in-house treatment planning system. To generate the plan using a very few beams, gantry angle was optimized by weighting the beam monitoring unit (MU), and beam shape optimization was a combination of column search with k-means clustering. A prostate case and a head and neck case were planned using r-IMRT. The dosimetry is compared to s-IMRT planned with Varian Eclipse treatment planning system. Results: With the same PTV dose coverage D95=100%, the r-IMRT plans shows comparable sparing as the s-IMRT plans in the prostate for the rectum D10cc and the bladder Dmean, and in the head and neck for the spinal cord Dmax, the brain stem Dmax, the left/right parotid Dmean, the larynx Dmean, and the mandible Dmean. Both plans meet the established institutional clinical dosimetric criteria. The r-IMRT plan uses 19 beam/405 MU for the prostate, and 68 beam/880 MU for the head and neck, while the s-IMRT uses 7 beam/724 MU and 9 beam/1812 MU, respectively. Compared to the corresponding s-IMRT, r-IMRT has a reduction of MUs of 44% for the prostate case and 41% for the head and neck case. Conclusions: We have demonstrated the feasibility of a rotational step and shoot IMRT treatment planning approach that significantly shortens the conventional IMRT treatment beam-on time without degrading the dose comformity

  16. SU-E-T-521: Feasibility Study of a Rotational Step-And-Shoot IMRT Treatment Planning Approach

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, X [Univ. of North Carolina at Chapel Hill, Chapel Hill, NC (United States); Chang, S [UNC School of Medicine, Chapel Hill, NC (United States); Cullip, T [UNC Hospitals, Chapel Hill, NC (United States); Yuan, L; Zhang, X [Duke University, Durham, NC (United States); Lian, J; Tang, X [UniversityNorth Carolina, Chapel Hill, NC (United States); Tracton, G; Dooley, J [University of North Carolina, Chapel Hill, NC (United States)

    2014-06-01

    Purpose: Rotational step-and-shot IMRT (r-IMRT) could improve delivery efficiency with good dose conformity, especially if it can leverage the burst mode of the accelerator where radiation is turned on/off momentarily while the gantry rotates continuously. The challenge for the r-IMRT planning is to minimize the number of beams to achieve a fast and smooth rotational delivery. Methods: Treatment plans for r-IMRT were created using an in-house treatment planning system. To generate the plan using a very few beams, gantry angle was optimized by weighting the beam monitoring unit (MU), and beam shape optimization was a combination of column search with k-means clustering. A prostate case and a head and neck case were planned using r-IMRT. The dosimetry is compared to s-IMRT planned with Varian Eclipse treatment planning system. Results: With the same PTV dose coverage D95=100%, the r-IMRT plans shows comparable sparing as the s-IMRT plans in the prostate for the rectum D10cc and the bladder Dmean, and in the head and neck for the spinal cord Dmax, the brain stem Dmax, the left/right parotid Dmean, the larynx Dmean, and the mandible Dmean. Both plans meet the established institutional clinical dosimetric criteria. The r-IMRT plan uses 19 beam/405 MU for the prostate, and 68 beam/880 MU for the head and neck, while the s-IMRT uses 7 beam/724 MU and 9 beam/1812 MU, respectively. Compared to the corresponding s-IMRT, r-IMRT has a reduction of MUs of 44% for the prostate case and 41% for the head and neck case. Conclusions: We have demonstrated the feasibility of a rotational step and shoot IMRT treatment planning approach that significantly shortens the conventional IMRT treatment beam-on time without degrading the dose comformity.

  17. Effectiveness of the magnetic resonance imaging for the therapy of avascular necrosis of the femoral head

    International Nuclear Information System (INIS)

    Oda, Yoshinao; Katsuki, Ichirou; Ushijima, Masahiro; Tsutsui, Hideki; Sugioka, Youichi

    1990-01-01

    Recently, some reports demonstrate the usefulness of the magnetic resonance imaging (MRI) for early diagnosis of the avascular necrosis of the femoral head (ANF). In this report we analyzed 64 hips in 40 cases using preoperative plain radiographs, tomography and MRI affected by ANF. And we gained following three conclusions. When rotational osteotomy of the femoral head is to be carried out, two plain views of MRI, parallel and contrary to the axis of the femoral neck, were useful for evaluation of postoperative weight bearing area. In 58 hips with strinct the former two plain views of MRI, atrophy of posterior area of the femoral head was recognized in 54 hips by tomography, and of them abnormal signal in posterior was revealed in 32 hips by MRI. In 28 hips performed anterior rotational osteotomy, atrophy of posterior area of the femoral head was recognized in 26 hips by tomography, and of them abnormal signal in posterior was revealed in 6 hips by MRI. In such cases careful follow-up should be required. (author)

  18. Effectiveness of the magnetic resonance imaging for the therapy of avascular necrosis of the femoral head

    Energy Technology Data Exchange (ETDEWEB)

    Oda, Yoshinao; Katsuki, Ichirou; Ushijima, Masahiro; Tsutsui, Hideki; Sugioka, Youichi [Kyushu Univ., Fukuoka (Japan). Faculty of Medicine

    1990-03-01

    Recently, some reports demonstrate the usefulness of the magnetic resonance imaging (MRI) for early diagnosis of the avascular necrosis of the femoral head (ANF). In this report we analyzed 64 hips in 40 cases using preoperative plain radiographs, tomography and MRI affected by ANF. And we gained following three conclusions. When rotational osteotomy of the femoral head is to be carried out, two plain views of MRI, parallel and contrary to the axis of the femoral neck, were useful for evaluation of postoperative weight bearing area. In 58 hips with strinct the former two plain views of MRI, atrophy of posterior area of the femoral head was recognized in 54 hips by tomography, and of them abnormal signal in posterior was revealed in 32 hips by MRI. In 28 hips performed anterior rotational osteotomy, atrophy of posterior area of the femoral head was recognized in 26 hips by tomography, and of them abnormal signal in posterior was revealed in 6 hips by MRI. In such cases careful follow-up should be required. (author).

  19. Assessing women's lacrosse head impacts using finite element modelling.

    Science.gov (United States)

    Clark, J Michio; Hoshizaki, T Blaine; Gilchrist, Michael D

    2018-04-01

    Recently studies have assessed the ability of helmets to reduce peak linear and rotational acceleration for women's lacrosse head impacts. However, such measures have had low correlation with injury. Maximum principal strain interprets loading curves which provide better injury prediction than peak linear and rotational acceleration, especially in compliant situations which create low magnitude accelerations but long impact durations. The purpose of this study was to assess head and helmet impacts in women's lacrosse using finite element modelling. Linear and rotational acceleration loading curves from women's lacrosse impacts to a helmeted and an unhelmeted Hybrid III headform were input into the University College Dublin Brain Trauma Model. The finite element model was used to calculate maximum principal strain in the cerebrum. The results demonstrated for unhelmeted impacts, falls and ball impacts produce higher maximum principal strain values than stick and shoulder collisions. The strain values for falls and ball impacts were found to be within the range of concussion and traumatic brain injury. The results also showed that men's lacrosse helmets reduced maximum principal strain for follow-through slashing, falls and ball impacts. These findings are novel and demonstrate that for high risk events, maximum principal strain can be reduced by implementing the use of helmets if the rules of the sport do not effectively manage such situations. Copyright © 2018 Elsevier Ltd. All rights reserved.

  20. Vibration of imperfect rotating disk

    Directory of Open Access Journals (Sweden)

    Půst L.

    2011-12-01

    Full Text Available This study is concerned with the theoretical and numerical calculations of the flexural vibrations of a bladed disk. The main focus of this study is to elaborate the basic background for diagnostic and identification methods for ascertaining the main properties of the real structure or an experimental model of turbine disks. The reduction of undesirable vibrations of blades is proposed by using damping heads, which on the experimental model of turbine disk are applied only on a limited number of blades. This partial setting of damping heads introduces imperfection in mass, stiffness and damping distribution on the periphery and leads to more complicated dynamic properties than those of a perfect disk. Calculation of FEM model and analytic—numerical solution of disk behaviour in the limited (two modes frequency range shows the splitting of resonance with an increasing speed of disk rotation. The spectrum of resonance is twice denser than that of a perfect disk.

  1. Dynamic Characteristics of Rotating Stall in Mixed Flow Pump

    Directory of Open Access Journals (Sweden)

    Xiaojun Li

    2013-01-01

    Full Text Available Rotating stall, a phenomenon that causes flow instabilities and pressure hysteresis by propagating at some fraction of the impeller rotational speed, can occur in centrifugal impellers, mixed impellers, radial diffusers, or axial diffusers. Despite considerable efforts devoted to the study of rotating stall in pumps, the mechanics of this phenomenon are not sufficiently understood. The propagation mechanism and onset of rotating stall are not only affected by inlet flow but also by outlet flow as well as the pressure gradient in the flow passage. As such, the complexity of these concepts is not covered by the classical explanation. To bridge this research gap, the current study investigated prerotation generated at the upstream of the impeller, leakage flow at the tip clearance between the casing and the impeller, and strong reserve flow at the inlet of the diffuser. Understanding these areas will clarify the origin of the positive slope of the head-flow performance curve for a mixed flow pump. Nonuniform pressure distribution and adverse pressure gradient were also introduced to evaluate the onset and development of rotating stall within the diffuser.

  2. Effect of external viscous load on head movement

    Science.gov (United States)

    Nam, M.-H.; Lakshminarayanan, V.; Stark, L. W.

    1984-01-01

    Quantitative measurements of horizontal head rotation were obtained from normal human subjects intending to make 'time optimal' trajectories between targets. By mounting large, lightweight vanes on the head, viscous damping B, up to 15 times normal could be added to the usual mechanical load of the head. With the added viscosity, the head trajectory was slowed and of larger duration (as expected) since fixed and maximal (for that amplitude) muscle forces had to accelerate the added viscous load. This decreased acceleration and velocity and longer duration movement still ensued in spite of adaptive compensation; this provided evidence that quasi-'time optimal' movements do indeed employ maximal muscle forces. The adaptation to this added load was rapid. Then the 'adapted state' subjects produced changed trajectories. The adaptation depended in part on the differing detailed instructions given to the subjects. This differential adaptation provided evidence for the existence of preprogrammed controller signals, sensitive to intended criterion, and neurologically ballistic or open loop rather than modified by feedback from proprioceptors or vision.

  3. Cortical evoked potentials to an auditory illusion: binaural beats.

    Science.gov (United States)

    Pratt, Hillel; Starr, Arnold; Michalewski, Henry J; Dimitrijevic, Andrew; Bleich, Naomi; Mittelman, Nomi

    2009-08-01

    To define brain activity corresponding to an auditory illusion of 3 and 6Hz binaural beats in 250Hz or 1000Hz base frequencies, and compare it to the sound onset response. Event-Related Potentials (ERPs) were recorded in response to unmodulated tones of 250 or 1000Hz to one ear and 3 or 6Hz higher to the other, creating an illusion of amplitude modulations (beats) of 3Hz and 6Hz, in base frequencies of 250Hz and 1000Hz. Tones were 2000ms in duration and presented with approximately 1s intervals. Latency, amplitude and source current density estimates of ERP components to tone onset and subsequent beats-evoked oscillations were determined and compared across beat frequencies with both base frequencies. All stimuli evoked tone-onset P(50), N(100) and P(200) components followed by oscillations corresponding to the beat frequency, and a subsequent tone-offset complex. Beats-evoked oscillations were higher in amplitude with the low base frequency and to the low beat frequency. Sources of the beats-evoked oscillations across all stimulus conditions located mostly to left lateral and inferior temporal lobe areas in all stimulus conditions. Onset-evoked components were not different across stimulus conditions; P(50) had significantly different sources than the beats-evoked oscillations; and N(100) and P(200) sources located to the same temporal lobe regions as beats-evoked oscillations, but were bilateral and also included frontal and parietal contributions. Neural activity with slightly different volley frequencies from left and right ear converges and interacts in the central auditory brainstem pathways to generate beats of neural activity to modulate activities in the left temporal lobe, giving rise to the illusion of binaural beats. Cortical potentials recorded to binaural beats are distinct from onset responses. Brain activity corresponding to an auditory illusion of low frequency beats can be recorded from the scalp.

  4. The Effect of Head Positioning and Head Tilting on the Incidence of Intraventricular Hemorrhage in Very Preterm Infants: A Systematic Review.

    Science.gov (United States)

    de Bijl-Marcus, Karen A; Brouwer, Annemieke J; de Vries, Linda S; van Wezel-Meijler, Gerda

    2017-01-01

    Despite advances in neonatal intensive care, germinal matrix-intraventricular hemorrhage (GMH-IVH) remains a frequent, serious complication of premature birth. Neutral head position and head tilting have been suggested to reduce the risk of GMH-IVH in preterm infants during the first 72 h of life. The aim of this study was to provide a systematic review of the effect of neutral head positioning and head tilting on the incidence of GMH-IVH in very preterm infants (gestational age ≤30 weeks). In addition, we reviewed their effect on cerebral hemodynamics and oxygenation. Literature was searched (June 2016) in the following electronic databases: CINAHL, Embase, Medline, SCOPUS, and several trial registers. One underpowered trial studied the effect of head positioning on the incidence of GMH-IVH. This randomized controlled trial enrolled 48 preterm infants and found no effect on the occurrence of GMH-IVH. Three observational studies investigated the effect of head rotation and/or tilting on cerebral oxygenation in 68 preterm infants in total. Their results suggest that cerebral oxygenation is not significantly affected by changes in head positioning. The effect of head positioning and/or tilting on cerebral hemodynamics was described in 2 observational studies of 28 preterm infants and found no significant effect. There is insufficient evidence regarding the effect of head positioning and tilting on the incidence of GMH-IVH and cerebral hemodynamics and oxygenation in preterm infants. We recommend further research in this field, especially in extremely preterm and clinically unstable infants during the first postnatal days. © 2016 S. Karger AG, Basel.

  5. Brain correlates of music-evoked emotions.

    Science.gov (United States)

    Koelsch, Stefan

    2014-03-01

    Music is a universal feature of human societies, partly owing to its power to evoke strong emotions and influence moods. During the past decade, the investigation of the neural correlates of music-evoked emotions has been invaluable for the understanding of human emotion. Functional neuroimaging studies on music and emotion show that music can modulate activity in brain structures that are known to be crucially involved in emotion, such as the amygdala, nucleus accumbens, hypothalamus, hippocampus, insula, cingulate cortex and orbitofrontal cortex. The potential of music to modulate activity in these structures has important implications for the use of music in the treatment of psychiatric and neurological disorders.

  6. The influence of applied internal and external rotation on the pivot shift phenomenon.

    Science.gov (United States)

    Kopf, Sebastian; Musahl, Volker; Perka, Carsten; Kauert, Ralf; Hoburg, Arnd; Becker, Roland

    2017-04-01

    The pivot shift test is performed in different techniques and the rotation of the tibia seems to have a significant impact on the amount of the pivot shift phenomenon. It has been hypothesised that external rotation will increase the phenomenon due to less tension at the iliotibial band in knee extension. Twenty-four patients with unilateral anterior cruciate ligament insufficiency were included prospectively. The pivot shift test was performed bilaterally in internal and external tibial rotation under general anaesthesia. Knee motion was captured using a femoral and a tibial inertial sensor. The difference between positive and negative peak values in Euclidean norm of acceleration was calculated to evaluate the amount of the pivot shift phenomenon. The pivot shift phenomenon was significantly increased in patients with ACL insufficiency when the test was performed in external [mean 5.2 ms - 2 (95% CI 4.3-6.0)] compared to internal tibial rotation [mean 4.4 ms - 2 (95% CI 3.5-5.4)] (p = 0.002). In healthy, contralateral knees did not show any difference between external [mean 4.0 ms - 2 (95% CI 3.3-4.7)] and internal tibial rotation [mean 4.0 ms - 2 (95% CI 3.4-4.6)] (ns). The pivot shift phenomenon was increased with external rotation in ACL-insufficient knees, and therefore, one should perform the pivot shift test, rather, in external rotation to easily evoke the, sometimes difficult to detect, pivot shift phenomenon. I (diagnostic study).

  7. An inventory and update of jealousy-evoking partner behaviours in modern society.

    NARCIS (Netherlands)

    Dijkstra, Pieternel; Barelds, Dick P. H.; Groothof, Hinke A. K.

    2010-01-01

    The goal of the present study was to identify the most important jealousy-evoking partner behaviours and to examine the extent to which these behaviours evoke jealousy. Based on the literature, a questionnaire was constructed containing 42 jealousy-evoking partner behaviours, including a partner's

  8. HYDROïD humanoid robot head with perception and emotion capabilities :Modeling, Design and Experimental Results

    Directory of Open Access Journals (Sweden)

    Samer eAlfayad

    2016-04-01

    Full Text Available In the framework of the HYDROïD humanoid robot project, this paper describes the modeling and design of an electrically actuated head mechanism. Perception and emotion capabilities are considered in the design process. Since HYDROïD humanoid robot is hydraulically actuated, the choice of electrical actuation for the head mechanism addressed in this paper is justified. Considering perception and emotion capabilities leads to a total number of 15 degrees of freedom for the head mechanism which are split on four main sub-mechanisms: the neck, the mouth, the eyes and the eyebrows. Biological data and kinematics performances of human head are taken as inputs of the design process. A new solution of uncoupled eyes is developed to possibly address the master-slave process that links the human eyes as well as vergence capabilities. Modeling each sub-system is carried out in order to get equations of motion, their frequency responses and their transfer functions. The neck pitch rotation is given as a study example. Then, the head mechanism performances are presented through a comparison between model and experimental results validating the hardware capabilities. Finally, the head mechanism is integrated on the HYDROïD upper-body. An object tracking experiment coupled with emotional expressions is carried out to validate the synchronization of the eye rotations with the body motions.

  9. Clinical and Radiographic Outcomes of Unipolar and Bipolar Radial Head Prosthesis in Patients with Radial Head Fracture: A Systemic Review and Meta-Analysis.

    Science.gov (United States)

    Chen, Hongwei; Wang, Ziyang; Shang, Yongjun

    2018-06-01

    To compare clinical outcomes of unipolar and bipolar radial head prosthesis in the treatment of patients with radial head fracture. Medline, Cochrane, EMBASE, Google Scholar databases were searched until April 18, 2016 using the following search terms: radial head fracture, elbow fracture, radial head arthroplasty, implants, prosthesis, unipolar, bipolar, cemented, and press-fit. Randomized controlled trials, retrospective, and cohort studies were included. The Mayo elbow performance score (MEPS), disabilities of the arm, shoulder, and hand (DASH) score, radiologic assessment, ROM, and grip strength following elbow replacement were similar between prosthetic devices. The pooled mean excellent/good ranking of MEPS was 0.78 for unipolar and 0.73 for bipolar radial head arthroplasty, and the pooled mean MEPS was 86.9 and 79.9, respectively. DASH scores for unipolar and bipolar prosthesis were 19.0 and 16.3, respectively. Range of motion outcomes were similar between groups, with both groups have comparable risk of flexion arc, flexion, extension deficit, rotation arc, pronation, and supination (p values bipolar prosthesis). However, bipolar radial head prosthesis was associated with an increased chance of heterotopic ossification and lucency (p values ≤0.049) while unipolar prosthesis was not (p values ≥0.088). Both groups had risk for development of capitellar osteopenia or erosion/wear (p values ≤0.039). Unipolar and bipolar radial head prostheses were similar with respect to clinical outcomes. Additional comparative studies are necessary to further compare different radial head prostheses used to treat radial head fracture.

  10. Music-evoked emotions: principles, brain correlates, and implications for therapy.

    Science.gov (United States)

    Koelsch, Stefan

    2015-03-01

    This paper describes principles underlying the evocation of emotion with music: evaluation, resonance, memory, expectancy/tension, imagination, understanding, and social functions. Each of these principles includes several subprinciples, and the framework on music-evoked emotions emerging from these principles and subprinciples is supposed to provide a starting point for a systematic, coherent, and comprehensive theory on music-evoked emotions that considers both reception and production of music, as well as the relevance of emotion-evoking principles for music therapy. © 2015 New York Academy of Sciences.

  11. Attention to affective pictures in closed head injury: event-related brain potentials and cardiac responses.

    Science.gov (United States)

    Solbakk, Anne-Kristin; Reinvang, Ivar; Svebak, Sven; Nielsen, Christopher S; Sundet, Kjetil

    2005-02-01

    We examined whether closed head injury patients show altered patterns of selective attention to stimulus categories that naturally evoke differential responses in healthy people. Self-reported rating and electrophysiological (event-related potentials [ERPs], heart rate [HR]) responses to affective pictures were studied in patients with mild head injury (n = 20; CT/MRI negative), in patients with predominantly frontal brain lesions (n = 12; CT/MRI confirmed), and in healthy controls (n = 20). Affective valence similarly modulated HR and ERP responses in all groups, but group differences occurred that were independent of picture valence. The attenuation of P3-slow wave amplitudes in the mild head injury group indicates a reduction in the engagement of attentional resources to the task. In contrast, the general enhancement of ERP amplitudes at occipital sites in the group with primarily frontal brain injury may reflect disinhibition of input at sensory receptive areas, possibly due to a deficit in top-down modulation performed by anterior control systems.

  12. Vibration and muscle contraction affect somatosensory evoked potentials

    OpenAIRE

    Cohen, LG; Starr, A

    1985-01-01

    We recorded potentials evoked by specific somatosensory stimuli over peripheral nerve, spinal cord, and cerebral cortex. Vibration attenuated spinal and cerebral potentials evoked by mixed nerve and muscle spindle stimulation; in one subject that was tested, there was no effect on cutaneous input. Presynaptic inhibition of Ia input in the spinal cord and muscle spindle receptor occupancy are probably the responsible mechanisms. In contrast, muscle contraction attenuated cerebral potentials to...

  13. Aging increases compensatory saccade amplitude in the video head impulse test

    Directory of Open Access Journals (Sweden)

    Eric R Anson

    2016-07-01

    Full Text Available Objective: Rotational vestibular function declines with age resulting in saccades as a compensatory mechanism to improve impaired gaze stability. Small reductions in rotational vestibulo-ocular reflex (VOR gain that would be considered clinically normal have been associated with compensatory saccades. We evaluated whether compensatory saccade characteristics varied as a function of age, independent of semicircular canal function as quantified by VOR gain.Methods: Horizontal VOR gain was measured in 243 participants age 27-93 from the Baltimore Longitudinal Study of Aging using video head impulse testing (HIT. Latency and amplitude of the first saccade (either covert – occurring during head impulse, or overt – occurring following head impulse were measured for head impulses with compensatory saccades (n = 2230 head impulses. The relationship between age and saccade latency, as well as the relationship between age and saccade amplitude, were evaluated using regression analyses adjusting for VOR gain, gender, and race.Results: Older adults (mean age 75.9 made significantly larger compensatory saccades relative to younger adults (mean age 45.0. In analyses adjusted for VOR gain, there was a significant association between age and amplitude of the first compensatory covert saccade (β = 0.015, p = 0.008. In analyses adjusted for VOR gain, there was a significant association between age and amplitude of the first compensatory overt saccade (β = 0.02, p < 0.001. Compensatory saccade latencies did not vary significantly by age. Conclusions: We observed that aging increases the compensatory catch-up saccade amplitude in healthy adults after controlling for VOR gain. Size of compensatory saccades may be useful in addition to VOR gain for characterizing vestibular function in aging adults.

  14. Muscle synergies evoked by microstimulation are preferentially encoded during behavior

    Directory of Open Access Journals (Sweden)

    Simon Alexander Overduin

    2014-03-01

    Full Text Available Electrical microstimulation studies provide some of the most direct evidence for the neural representation of muscle synergies. These synergies, i.e. coordinated activations of groups of muscles, have been proposed as building blocks for the construction of motor behaviors by the nervous system. Intraspinal or intracortical microstimulation has been shown to evoke muscle patterns that can be resolved into a small set of synergies similar to those seen in natural behavior. However, questions remain about the validity of microstimulation as a probe of neural function, particularly given the relatively long trains of supratheshold stimuli used in these studies. Here, we examined whether muscle synergies evoked during intracortical microstimulation in two rhesus macaques were similarly encoded by nearby motor cortical units during a purely voluntary behavior involving object reach, grasp, and carry movements. At each microstimulation site we identified the synergy most strongly evoked among those extracted from muscle patterns evoked over all microstimulation sites. For each cortical unit recorded at the same microstimulation site, we then identified the synergy most strongly encoded among those extracted from muscle patterns recorded during the voluntary behavior. We found that the synergy most strongly evoked at an intracortical microstimulation site matched the synergy most strongly encoded by proximal units more often than expected by chance. These results suggest a common neural substrate for microstimulation-evoked motor responses and for the generation of muscle patterns during natural behaviors.

  15. The involuntary nature of music-evoked autobiographical memories in Alzheimer's disease.

    Science.gov (United States)

    El Haj, Mohamad; Fasotti, Luciano; Allain, Philippe

    2012-03-01

    The main objective of this paper was to examine the involuntary nature of music-evoked autobiographical memories. For this purpose, young adults, older adults, and patients with a clinical diagnosis of probable Alzheimer's disease (AD) were asked to remember autobiographical events in two conditions: after being exposed to their own chosen music, and in silence. Compared to memories evoked in silence, memories evoked in the "Music" condition were found to be more specific, accompanied by more emotional content and impact on mood, and retrieved faster. In addition, these memories engaged less executive processes. Thus, with all these characteristics and the fact that they are activated by a perceptual cue (i.e., music), music-evoked autobiographic memories have all the features to be considered as involuntary memories. Our paper reveals several characteristics of music-evoked autobiographical memories in AD patients and offers a theoretical background for this phenomenon. Copyright © 2012 Elsevier Inc. All rights reserved.

  16. Similar head impact acceleration measured using instrumented ear patches in a junior rugby union team during matches in comparison with other sports.

    Science.gov (United States)

    King, Doug A; Hume, Patria A; Gissane, Conor; Clark, Trevor N

    2016-07-01

    OBJECTIVE Direct impact with the head and the inertial loading of the head have been postulated as major mechanisms of head-related injuries, such as concussion. METHODS This descriptive observational study was conducted to quantify the head impact acceleration characteristics in under-9-year-old junior rugby union players in New Zealand. The impact magnitude, frequency, and location were collected with a wireless head impact sensor that was worn by 14 junior rugby players who participated in 4 matches. RESULTS A total of 721 impacts > 10g were recorded. The median (interquartile range [IQR]) number of impacts per player was 46 (IQR 37-58), resulting in 10 (IQR 4-18) impacts to the head per player per match. The median impact magnitudes recorded were 15g (IQR 12g-21g) for linear acceleration and 2296 rad/sec(2) (IQR 1352-4152 rad/sec(2)) for rotational acceleration. CONCLUSIONS There were 121 impacts (16.8%) above the rotational injury risk limit and 1 (0.1%) impact above the linear injury risk limit. The acceleration magnitude and number of head impacts in junior rugby union players were higher than those previously reported in similar age-group sports participants. The median linear acceleration for the under-9-year-old rugby players were similar to 7- to 8-year-old American football players, but lower than 9- to 12-year-old youth American football players. The median rotational accelerations measured were higher than the median and 95th percentiles in youth, high school, and collegiate American football players.

  17. Geometric calibration method for multiple head cone beam SPECT systems

    International Nuclear Information System (INIS)

    Rizo, Ph.; Grangeat, P.; Guillemaud, R.; Sauze, R.

    1993-01-01

    A method is presented for performing geometric calibration on Single Photon Emission Tomography (SPECT) cone beam systems with multiple cone beam collimators, each having its own orientation parameters. This calibration method relies on the fact that, in tomography, for each head, the relative position of the rotation axis and of the collimator does not change during the acquisition. In order to ensure the method stability, the parameters to be estimated in intrinsic parameters and extrinsic parameters are separated. The intrinsic parameters describe the acquisition geometry and the extrinsic parameters position of the detection system with respect to the rotation axis. (authors) 3 refs

  18. Effect of spaceflight on the spatial orientation of the vestibulo-ocular reflex during eccentric roll rotation: A case report.

    Science.gov (United States)

    Reschke, Millard F; Wood, Scott J; Clément, Gilles

    2018-01-01

    Ground-based studies have reported shifts of the vestibulo-ocular reflex (VOR) slow phase velocity (SPV) axis toward the resultant gravito-inertial force vector. The VOR was examined during eccentric roll rotation before, during and after an 8-day orbital mission. On orbit this vector is aligned with the head z-axis. Our hypothesis was that eccentric roll rotation on orbit would generate horizontal eye movements. Two subjects were rotated in a semi-supine position with the head nasal-occipital axis parallel to the axis of rotation and 0.5 m off-center. The chair accelerated at 120 deg/s2 to 120 deg/s, rotated at constant velocity for one minute, and then decelerated to a stop in similar fashion. On Earth, the stimulation primarily generated torsional VOR. During spaceflight, in one subject torsional VOR became horizontal VOR, and then decayed very slowly. In the other subject, torsional VOR was reduced on orbit relative to pre- and post-flight, but the SPV axis did not rotate. We attribute the shift from torsional to horizontal VOR on orbit to a spatial orientation of velocity storage toward alignment with the gravito-inertial force vector, and the inter-individual difference to cognitive factors related to the subjective straight-ahead.

  19. Universal crystal cooling device for precession cameras, rotation cameras and diffractometers

    International Nuclear Information System (INIS)

    Hajdu, J.; McLaughlin, P.J.; Helliwell, J.R.; Sheldon, J.; Thompson, A.W.

    1985-01-01

    A versatile crystal cooling device is described for macromolecular crystallographic applications in the 290 to 80 K temperature range. It utilizes a fluctuation-free cold-nitrogen-gas supply, an insulated Mylar crystal cooling chamber and a universal ball joint, which connects the cooling chamber to the goniometer head and the crystal. The ball joint is a novel feature over all previous designs. As a result, the device can be used on various rotation cameras, precession cameras and diffractometers. The lubrication of the interconnecting parts with graphite allows the cooling chamber to remain stationary while the crystal and goniometer rotate. The construction allows for 360 0 rotation of the crystal around the goniometer axis and permits any settings on the arcs and slides of the goniometer head (even if working at 80 K). There are no blind regions associated with the frame holding the chamber. Alternatively, the interconnecting ball joint can be tightened and fixed. This results in a set up similar to the construction described by Bartunik and Schubert where the cooling chamber rotates with the crystal. The flexibility of the systems allows for the use of the device on most cameras or diffractometers. THis device has been installed at the protein crystallographic stations of the Synchrotron Radiation Source at Daresbury Laboratory and in the Laboratory of Molecular Biophysics, Oxford. Several data sets have been collected with processing statistics typical of data collected without a cooling chamber. Tests using the full white beam of the synchrotron also look promising. (orig./BHO)

  20. Rotating gravity currents. Part 1. Energy loss theory

    Science.gov (United States)

    Martin, J. R.; Lane-Serff, G. F.

    2005-01-01

    A comprehensive energy loss theory for gravity currents in rotating rectangular channels is presented. The model is an extension of the non-rotating energy loss theory of Benjamin (J. Fluid Mech. vol. 31, 1968, p. 209) and the steady-state dissipationless theory of rotating gravity currents of Hacker (PhD thesis, 1996). The theory assumes the fluid is inviscid, there is no shear within the current, and the Boussinesq approximation is made. Dissipation is introduced using a simple method. A head loss term is introduced into the Bernoulli equation and it is assumed that the energy loss is uniform across the stream. Conservation of momentum, volume flux and potential vorticity between upstream and downstream locations is then considered. By allowing for energy dissipation, results are obtained for channels of arbitrary depth and width (relative to the current). The results match those from earlier workers in the two limits of (i) zero rotation (but including dissipation) and (ii) zero dissipation (but including rotation). Three types of flow are identified as the effect of rotation increases, characterized in terms of the location of the outcropping interface between the gravity current and the ambient fluid on the channel boundaries. The parameters for transitions between these cases are quantified, as is the detailed behaviour of the flow in all cases. In particular, the speed of the current can be predicted for any given channel depth and width. As the channel depth increases, the predicted Froude number tends to surd 2, as for non-rotating flows.

  1. Absence of Rotation Perception during Warm Water Caloric Irrigation in Some Seniors with Postural Instability.

    Science.gov (United States)

    Chiarovano, Elodie; Vidal, Pierre-Paul; Magnani, Christophe; Lamas, Georges; Curthoys, Ian S; de Waele, Catherine

    2016-01-01

    Falls in seniors are a major public health problem. Falls lead to fear of falling, reduced mobility, and decreased quality of life. Vestibular dysfunction is one of the fall risk factors. The relationship between objective measures of vestibular responses and age has been studied. However, the effects of age on vestibular perception during caloric stimulation have not been studied. Twenty senior subjects were included in the study, and separated in two groups: 10 seniors reporting postural instability (PI) and exhibiting absence of vestibular perception when they tested with caloric stimulation and 10 sex- and age-matched seniors with no such problems (controls). We assessed vestibular perception on a binary rating scale during the warm irrigation of the caloric test. The function of the various vestibular receptors was assessed using video head impulse test (vHIT), caloric tests, and cervical and ocular vestibular-evoked myogenic potentials. The Equitest was used to evaluate balance. No horizontal canal dysfunction assessed using both caloric test and vHIT was detected in either group. No significant difference was detected between PI and control groups for the peak SPV of caloric-induced ocular nystagmus or for the HVOR gain. All the controls perceived rotation when the maximal SPV during warm irrigation was equal to or ≥15°/s. None of the subjects in the PI group perceived rotation even while the peak SPV exceeded 15°/s, providing objective evidence of normal peripheral horizontal canal function. All the PI group had abnormal Equitest results, particularly in the two last conditions. These investigations show for the first time that vestibular perception can be absent during a caloric test despite normal horizontal canal function. We call this as dissociation vestibular neglect. Patients with poor vestibular perception may not be aware of postural perturbations and so will not correct for them. Thus, falls in the elderly may result, among other factors, from

  2. Experimental analysis of flow structure in contra-rotating axial flow pump designed with different rotational speed concept

    Science.gov (United States)

    Cao, Linlin; Watanabe, Satoshi; Imanishi, Toshiki; Yoshimura, Hiroaki; Furukawa, Akinori

    2013-08-01

    As a high specific speed pump, the contra-rotating axial flow pump distinguishes itself in a rear rotor rotating in the opposite direction of the front rotor, which remarkably contributes to the energy conversion, the reduction of the pump size, better hydraulic and cavitation performances. However, with two rotors rotating reversely, the significant interaction between blade rows was observed in our prototype contra-rotating rotors, which highly affected the pump performance compared with the conventional axial flow pumps. Consequently, a new type of rear rotor was designed by the rotational speed optimization methodology with some additional considerations, aiming at better cavitation performance, the reduction of blade rows interaction and the secondary flow suppression. The new rear rotor showed a satisfactory performance at the design flow rate but an unfavorable positive slope of the head — flow rate curve in the partial flow rate range less than 40% of the design flow rate, which should be avoided for the reliability of pump-pipe systems. In the present research, to understand the internal flow field of new rear rotor and its relation to the performances at the partial flow rates, the velocity distributions at the inlets and outlets of the rotors are firstly investigated. Then, the boundary layer flows on rotor surfaces, which clearly reflect the secondary flow inside the rotors, are analyzed through the limiting streamline observations using the multi-color oil-film method. Finally, the unsteady numerical simulations are carried out to understand the complicated internal flow structures in the rotors.

  3. Validation of a noninvasive system for measuring head acceleration for use during boxing competition.

    Science.gov (United States)

    Beckwith, Jonathan G; Chu, Jeffrey J; Greenwald, Richard M

    2007-08-01

    Although the epidemiology and mechanics of concussion in sports have been investigated for many years, the biomechanical factors that contribute to mild traumatic brain injury remain unclear because of the difficulties in measuring impact events in the field. The purpose of this study was to validate an instrumented boxing headgear (IBH) that can be used to measure impact severity and location during play. The instrumented boxing headgear data were processed to determine linear and rotational acceleration at the head center of gravity, impact location, and impact severity metrics, such as the Head Injury Criterion (HIC) and Gadd Severity Index (GSI). The instrumented boxing headgear was fitted to a Hybrid III (HIII) head form and impacted with a weighted pendulum to characterize accuracy and repeatability. Fifty-six impacts over 3 speeds and 5 locations were used to simulate blows most commonly observed in boxing. A high correlation between the HIII and instrumented boxing headgear was established for peak linear and rotational acceleration (r2= 0.91), HIC (r2 = 0.88), and GSI (r2 = 0.89). Mean location error was 9.7 +/- 5.2 masculine. Based on this study, the IBH is a valid system for measuring head acceleration and impact location that can be integrated into training and competition.

  4. Gender differences in binaural speech-evoked auditory brainstem response: are they clinically significant?

    Science.gov (United States)

    Jalaei, Bahram; Azmi, Mohd Hafiz Afifi Mohd; Zakaria, Mohd Normani

    2018-05-17

    Binaurally evoked auditory evoked potentials have good diagnostic values when testing subjects with central auditory deficits. The literature on speech-evoked auditory brainstem response evoked by binaural stimulation is in fact limited. Gender disparities in speech-evoked auditory brainstem response results have been consistently noted but the magnitude of gender difference has not been reported. The present study aimed to compare the magnitude of gender difference in speech-evoked auditory brainstem response results between monaural and binaural stimulations. A total of 34 healthy Asian adults aged 19-30 years participated in this comparative study. Eighteen of them were females (mean age=23.6±2.3 years) and the remaining sixteen were males (mean age=22.0±2.3 years). For each subject, speech-evoked auditory brainstem response was recorded with the synthesized syllable /da/ presented monaurally and binaurally. While latencies were not affected (p>0.05), the binaural stimulation produced statistically higher speech-evoked auditory brainstem response amplitudes than the monaural stimulation (p0.80), substantive gender differences were noted in most of speech-evoked auditory brainstem response peaks for both stimulation modes. The magnitude of gender difference between the two stimulation modes revealed some distinct patterns. Based on these clinically significant results, gender-specific normative data are highly recommended when using speech-evoked auditory brainstem response for clinical and future applications. The preliminary normative data provided in the present study can serve as the reference for future studies on this test among Asian adults. Copyright © 2018 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  5. Progressive addition spectacle lenses: Design preferences and head movements while reading

    Science.gov (United States)

    Preston, Julie Lynn

    In a subjective preference study, two key progressive addition lens parameters, near zone width and corridor length, were varied in a double-masked, randomized, clinical trial of 49 patients. Each subject received a complete eye examination and a new frame. Each wore 6 pairs of lenses for one week at a time and completed questionnaires relating to vision, adaptation, and satisfaction. The preferred lens was identified from the three near zone width lenses and from the three corridor length lenses. Patient characteristics were analyzed for their effect on design preference. Satisfaction ratings following a brief experience with each design were compared to ratings after one week of wear in order to ascertain the predictability of initial impressions. One lens design appeared twice in the preference trial, providing an assessment of the repeatability of the rating instrument. The lens design with the widest near zone was rated significantly lower than the other near zone width designs for nearly every question relating to vision, adaptation, and satisfaction. This lens was also least preferred of all the designs. Preferences for corridor length were evenly distributed among the three designs. Of patient characteristics, years of progressive addition lens wear and gender significantly affected design preference in this population. Initial impressions were not predictive of satisfaction after a week of wear. The rating instrument was judged to have low repeatability. In the head movement portion of the study, 18 participants from the preference study wore the three near zone width designs while reading three paragraphs of varying print size. From a 20 second recording for each of three different paragraphs with each lens, measures of head rotation and posture were collected. The amplitude of head rotation was significantly affected by print size but not by lens design. The effective zone widths on the lenses scanned by the eyes and the locations of the reading levels

  6. Head Impact Biomechanics in Women's College Soccer.

    Science.gov (United States)

    Lynall, Robert C; Clark, Michael D; Grand, Erin E; Stucker, Jaclyn C; Littleton, Ashley C; Aguilar, Alain J; Petschauer, Meredith A; Teel, Elizabeth F; Mihalik, Jason P

    2016-09-01

    There are limited nonlaboratory soccer head impact biomechanics data. This is surprising given soccer's global popularity. Epidemiological data suggest that female college soccer players are at a greater concussion injury risk than their male counterparts. Therefore, the purposes of our study were to quantify head impact frequency and magnitude during women's soccer practices and games in the National Collegiate Athletic Association and to characterize these data across event type, playing position, year on the team, and segment of game (first and second halves). Head impact biomechanics were collected from female college soccer players (n = 22; mean ± SD age = 19.1 ± 0.1 yr, height = 168.0 ± 3.5 cm, mass = 63.7 ± 6.0 kg). We employed a helmetless head impact measurement device (X2 Biosystems xPatch) before each competition and practice across a single season. Peak linear and rotational accelerations were categorized based on impact magnitude and subsequently analyzed using appropriate nonparametric analyses. Overall, women's college soccer players experience approximately seven impacts per 90 min of game play. The overwhelming majority (~90%) of all head impacts were categorized into our mildest linear acceleration impact classification (10g-20g). Interestingly, a higher percentage of practice impacts in the 20g-40g range compared with games (11% vs 7%) was observed. Head impact biomechanics studies have provided valuable insights into understanding collision sports and for informing evidence-based rule and policy changes. These have included changing the football kickoff, ice hockey body checking ages, and head-to-head hits in both sports. Given soccer's global popularity, and the growing public concern for the potential long-term neurological implications of collision and contact sports, studying soccer has the potential to impact many athletes and the sports medicine professionals caring for them.

  7. Influence of impact speed on head and brain injury outcome in vulnerable road user impacts to the car hood.

    Science.gov (United States)

    Fredriksson, Rikard; Zhang, Liying; Boström, Ola; Yang, King

    2007-10-01

    EuroNCAP and regulations in Europe and Japan evaluate the pedestrian protection performance of cars. The test methods are similar and they all have requirements for the passive protection of the hood area at a pedestrian to car impact speed of 40 km/h. In Europe, a proposal for a second phase of the regulation mandates a brake-assist system along with passive requirements. The system assists the driver in optimizing the braking performance during panic braking, resulting in activation only when the driver brakes sufficiently. In a European study this was estimated to occur in about 50% of pedestrian accidents. A future system for brake assistance will likely include automatic braking, in response to a pre-crash sensor, to avoid or mitigate injuries of vulnerable road users. An important question is whether these systems will provide sufficient protection, or if a parallel, passive pedestrian protection system will be necessary. This study investigated the influence of impact speed on head and brain injury risk, in impacts to the carhood. One car model was chosen and a rigid adjustable plate was mounted under the hood. Free-flying headform impacts were carried out at 20 and 30 km/h head impact velocities at different under-hood distances, 20 to 100 mm; and were compared to earlier tests at 40 km/h. The EEVC WG17 adult pedestrian headform was used for non-rotating tests and a Hybrid III adult 50th percentile head was used for rotational tests where linear and rotational acceleration was measured. Data from the rotational tests was used as input to a validated finite element model of the human head, the Wayne State University Head Injury Model (WSUHIM). The model was utilized to assess brain injury risk and potential injury mechanism in a pedestrian-hood impact. Although this study showed that it was not necessarily true that a lower HIC value reduced the risk for brain injury, it appeared, for the tested car model, under-hood distances of 60 mm in 20 km/h and 80 mm

  8. Head-Impact–Measurement Devices: A Systematic Review

    Science.gov (United States)

    O'Connor, Kathryn L.; Rowson, Steven; Duma, Stefan M.; Broglio, Steven P.

    2017-01-01

    Context: With an estimated 3.8 million sport- and recreation-related concussions occurring annually, targeted prevention and diagnostic methods are needed. Biomechanical analysis of head impacts may provide quantitative information that can inform both prevention and diagnostic strategies. Objective: To assess available head-impact devices and their clinical utility. Data Sources: We performed a systematic search of the electronic database PubMed for peer-reviewed publications, using the following phrases: accelerometer and concussion, head impact telemetry, head impacts and concussion and sensor, head impacts and sensor, impact sensor and concussion, linear acceleration and concussion, rotational acceleration and concussion, and xpatch concussion. In addition to the literature review, a Google search for head impact monitor and concussion monitor yielded 15 more devices. Study Selection: Included studies were performed in vivo, used commercially available devices, and focused on sport-related concussion. Data Extraction: One author reviewed the title and abstract of each study for inclusion and exclusion criteria and then reviewed each full-text article to confirm inclusion criteria. Controversial articles were reviewed by all authors to reach consensus. Data Synthesis: In total, 61 peer-reviewed articles involving 4 head-impact devices were included. Participants in boxing, football, ice hockey, soccer, or snow sports ranged in age from 6 to 24 years; 18% (n = 11) of the studies included female athletes. The Head Impact Telemetry System was the most widely used device (n = 53). Fourteen additional commercially available devices were presented. Conclusions: Measurements collected by impact monitors provided real-time data to estimate player exposure but did not have the requisite sensitivity to concussion. Proper interpretation of previously reported head-impact kinematics across age, sport, and position may inform future research and enable staff clinicians

  9. Music-Evoked Emotions—Current Studies

    Science.gov (United States)

    Schaefer, Hans-Eckhardt

    2017-01-01

    The present study is focused on a review of the current state of investigating music-evoked emotions experimentally, theoretically and with respect to their therapeutic potentials. After a concise historical overview and a schematic of the hearing mechanisms, experimental studies on music listeners and on music performers are discussed, starting with the presentation of characteristic musical stimuli and the basic features of tomographic imaging of emotional activation in the brain, such as functional magnetic resonance imaging (fMRI) and positron emission tomography (PET), which offer high spatial resolution in the millimeter range. The progress in correlating activation imaging in the brain to the psychological understanding of music-evoked emotion is demonstrated and some prospects for future research are outlined. Research in psychoneuroendocrinology and molecular markers is reviewed in the context of music-evoked emotions and the results indicate that the research in this area should be intensified. An assessment of studies involving measuring techniques with high temporal resolution down to the 10 ms range, as, e.g., electroencephalography (EEG), event-related brain potentials (ERP), magnetoencephalography (MEG), skin conductance response (SCR), finger temperature, and goose bump development (piloerection) can yield information on the dynamics and kinetics of emotion. Genetic investigations reviewed suggest the heredity transmission of a predilection for music. Theoretical approaches to musical emotion are directed to a unified model for experimental neurological evidence and aesthetic judgment. Finally, the reports on musical therapy are briefly outlined. The study concludes with an outlook on emerging technologies and future research fields. PMID:29225563

  10. Disorders of the long head of the biceps tendon.

    Science.gov (United States)

    Sethi, N; Wright, R; Yamaguchi, K

    1999-01-01

    Without a clear understanding of the functional role of the biceps tendon, treatment recommendations have been a subject of controversy. An objective review of the available information would suggest that some humeral head stability may be imparted through the tendon. However, the magnitude of this function is likely to be small and possibly insignificant. In contrast, the symptomatic significance of the long head of the biceps is less controversial, and it has become increasingly recognized as an important source of persistent shoulder pain when not specifically addressed. When present, persistent pain from the long head of the biceps is likely to have more negative functional consequences than loss of the tendon itself. Given these concerns, evaluation and treatment of patients with long head of the biceps disorders should be individualized, based on the likelihood that biceps-related pain will resolve. Although not universally accepted, we recommend tenodesis of the long head of the biceps in those cases in which there are either chronic inflammatory or structural changes, which would make it unlikely that the pain would resolve. These clinical situations in which tenodesis would be required include greater than 25% partial thickness tearing of the tendon, chronic atrophic changes of the tendon, any luxation of the biceps tendon from the bicipital groove, any disruption of associated bony or ligamentous anatomy of the bicipital groove that would make autotenodesis likely (i.e., 4-part fracture), and any significant reduction or atrophy of the size of the tendon that is more than 25% of the normal tendon width. Relative indications for biceps tenodesis also include biceps disease in the context of a failed decompression for rotator cuff tendinitis. It should be emphasized that routine tenodesis is not recommended during operative treatment for the rotator cuff. Rather, we avoid tenodesis whenever it is believed that inflammatory changes to the biceps tendon are

  11. Stimulator with arbitrary waveform for auditory evoked potentials

    International Nuclear Information System (INIS)

    Martins, H R; Romao, M; Placido, D; Provenzano, F; Tierra-Criollo, C J

    2007-01-01

    The technological improvement helps many medical areas. The audiometric exams involving the auditory evoked potentials can make better diagnoses of auditory disorders. This paper proposes the development of a stimulator based on Digital Signal Processor. This stimulator is the first step of an auditory evoked potential system based on the ADSP-BF533 EZ KIT LITE (Analog Devices Company - USA). The stimulator can generate arbitrary waveform like Sine Waves, Modulated Amplitude, Pulses, Bursts and Pips. The waveforms are generated through a graphical interface programmed in C++ in which the user can define the parameters of the waveform. Furthermore, the user can set the exam parameters as number of stimuli, time with stimulation (Time ON) and time without stimulus (Time OFF). In future works will be implemented another parts of the system that includes the acquirement of electroencephalogram and signal processing to estimate and analyze the evoked potential

  12. Stimulator with arbitrary waveform for auditory evoked potentials

    Energy Technology Data Exchange (ETDEWEB)

    Martins, H R; Romao, M; Placido, D; Provenzano, F; Tierra-Criollo, C J [Universidade Federal de Minas Gerais (UFMG), Departamento de Engenharia Eletrica (DEE), Nucleo de Estudos e Pesquisa em Engenharia Biomedica NEPEB, Av. Ant. Carlos, 6627, sala 2206, Pampulha, Belo Horizonte, MG, 31.270-901 (Brazil)

    2007-11-15

    The technological improvement helps many medical areas. The audiometric exams involving the auditory evoked potentials can make better diagnoses of auditory disorders. This paper proposes the development of a stimulator based on Digital Signal Processor. This stimulator is the first step of an auditory evoked potential system based on the ADSP-BF533 EZ KIT LITE (Analog Devices Company - USA). The stimulator can generate arbitrary waveform like Sine Waves, Modulated Amplitude, Pulses, Bursts and Pips. The waveforms are generated through a graphical interface programmed in C++ in which the user can define the parameters of the waveform. Furthermore, the user can set the exam parameters as number of stimuli, time with stimulation (Time ON) and time without stimulus (Time OFF). In future works will be implemented another parts of the system that includes the acquirement of electroencephalogram and signal processing to estimate and analyze the evoked potential.

  13. Evoking prescribed spike times in stochastic neurons

    Science.gov (United States)

    Doose, Jens; Lindner, Benjamin

    2017-09-01

    Single cell stimulation in vivo is a powerful tool to investigate the properties of single neurons and their functionality in neural networks. We present a method to determine a cell-specific stimulus that reliably evokes a prescribed spike train with high temporal precision of action potentials. We test the performance of this stimulus in simulations for two different stochastic neuron models. For a broad range of parameters and a neuron firing with intermediate firing rates (20-40 Hz) the reliability in evoking the prescribed spike train is close to its theoretical maximum that is mainly determined by the level of intrinsic noise.

  14. MACULA: Fast Modeling of Rotational Modulations of Spotty Stars

    Science.gov (United States)

    Kipping, David

    2015-08-01

    Rotational modulations are frequently observed on stars observed by photometry surveys such as Kepler, with periodicities ranging from days to months and amplitudes of sub-parts-per-million to several percent. These variations may be studied to reveal important stellar properties such as rotational periods, inclinations and gradients of differential rotation. However, inverting the disk-integrated flux into a solution for spot number, sizes, contrasts, etc is highly degenerate and thereby necessitating an exhaustive search of the parameter space. In recognition of this, the software MACULA is designed to be a fast forward model of circular, grey spots on rotating stars, including effects such as differential rotation, spot evolution and even spot penumbra/umbra. MACULA seeks to achieve computational efficiency by using a wholly analytic description of the disk-integrated flux, which is described in Kipping (2012), leading to a computational improvement of three orders-of-magnitude over its numerical counterparts. As part of the hack day, I'll show how to simulate light curves with MACULA and provide examples with visualizations. I will also discuss the on-going development of the code, which will head towards modeling spot crossing events and radial velocity jitter and I encourage discussions amongst the participants on analytic methods to this end.

  15. Visual evoked potentials in patients after methanol poisoning.

    Science.gov (United States)

    Urban, Pavel; Zakharov, Sergey; Diblík, Pavel; Pelclová, Daniela; Ridzoň, Petr

    2016-01-01

    We report the results of the visual evoked potentials (VEP) examination in patients after severe poisoning by methanol. The group of 47 patients (38 males and 9 females) was assembled out of persons who survived an outbreak of poisoning by the methanol adulterated alcohol beverages, which happened in the Czech Republic in 2012-2013. The visual evoked potentials examination was performed using monocular checkerboard pattern-reversal stimulation. Two criteria of abnormality were chosen: missing evoked response, and wave P1 latency > 117 ms. Non-parametric statistical methods (median, range, and the median test) were used to analyze factors influencing the VEP abnormality. The visual evoked potential was abnormal in 20 patients (43%), 5 of them had normal visual acuity on the Snellen chart. The VEP abnormality did not correlate significantly with initial serum concentrations of methanol, formic acid or lactate; however, it showed statistically significant inverse relation to the initial serum pH: the subgroup with the abnormal VEP had significantly lower median pH in comparison with the subgroup with the normal VEP (7.16 vs. 7.34, p = 0.04). The abnormality was not related to chronic alcohol abuse. The visual evoked potentials examination appeared sensitive enough to detected even subclinical impairment of the optic system. Metabolic acidosis is likely to be the key factor related to the development of visual damage induced by methanol. The examination performed with a delay of 1-9 months after the poisoning documented the situation relatively early after the event. It is considered as a baseline for the planned long-term follow-up of the patients, which will make it possible to assess the dynamics of the observed changes, their reversibility, and the occurrence of potential late sequelae. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  16. Evoked Emotions Predict Food Choice

    NARCIS (Netherlands)

    Dalenberg, Jelle R.; Gutjar, Swetlana; ter Horst, Gert J.; de Graaf, Kees; Renken, Remco J.; Jager, Gerry

    2014-01-01

    In the current study we show that non-verbal food-evoked emotion scores significantly improve food choice prediction over merely liking scores. Previous research has shown that liking measures correlate with choice. However, liking is no strong predictor for food choice in real life environments.

  17. The effects of curiosity-evoking events on activity enjoyment.

    Science.gov (United States)

    Isikman, Elif; MacInnis, Deborah J; Ülkümen, Gülden; Cavanaugh, Lisa A

    2016-09-01

    Whereas prior literature has studied the positive effects of curiosity-evoking events that are integral to focal activities, we explore whether and how a curiosity-evoking event that is incidental to a focal activity induces negative outcomes for enjoyment. Four experiments and 1 field study demonstrate that curiosity about an event that is incidental to an activity in which individuals are engaged, significantly affects enjoyment of a concurrent activity. The reason why is that curiosity diverts attention away from the concurrent activity and focuses attention on the curiosity-evoking event. Thus, curiosity regarding an incidental event decreases enjoyment of a positive focal activity but increases enjoyment of a negative focal activity. PsycINFO Database Record (c) 2016 APA, all rights reserved

  18. Symptoms of Pain Do Not Correlate with Rotator Cuff Tear Severity

    Science.gov (United States)

    Dunn, Warren R.; Kuhn, John E.; Sanders, Rosemary; An, Qi; Baumgarten, Keith M.; Bishop, Julie Y.; Brophy, Robert H.; Carey, James L.; Holloway, G. Brian; Jones, Grant L.; Ma, C. Benjamin; Marx, Robert G.; McCarty, Eric C.; Poddar, Sourav K.; Smith, Matthew V.; Spencer, Edwin E.; Vidal, Armando F.; Wolf, Brian R.; Wright, Rick W.

    2014-01-01

    Background: For many orthopaedic disorders, symptoms correlate with disease severity. The objective of this study was to determine if pain level is related to the severity of rotator cuff disorders. Methods: A cohort of 393 subjects with an atraumatic symptomatic full-thickness rotator-cuff tear treated with physical therapy was studied. Baseline pretreatment data were used to examine the relationship between the severity of rotator cuff disease and pain. Disease severity was determined by evaluating tear size, retraction, superior humeral head migration, and rotator cuff muscle atrophy. Pain was measured on the 10-point visual analog scale (VAS) in the patient-reported American Shoulder and Elbow Surgeons (ASES) score. A linear multiple regression model was constructed with use of the continuous VAS score as the dependent variable and measures of rotator cuff tear severity and other nonanatomic patient factors as the independent variables. Forty-eight percent of the patients were female, and the median age was sixty-one years. The dominant shoulder was involved in 69% of the patients. The duration of symptoms was less than one month for 8% of the patients, one to three months for 22%, four to six months for 20%, seven to twelve months for 15%, and more than a year for 36%. The tear involved only the supraspinatus in 72% of the patients; the supraspinatus and infraspinatus, with or without the teres minor, in 21%; and only the subscapularis in 7%. Humeral head migration was noted in 16%. Tendon retraction was minimal in 48%, midhumeral in 34%, glenohumeral in 13%, and to the glenoid in 5%. The median baseline VAS pain score was 4.4. Results: Multivariable modeling, controlling for other baseline factors, identified increased comorbidities (p = 0.002), lower education level (p = 0.004), and race (p = 0.041) as the only significant factors associated with pain on presentation. No measure of rotator cuff tear severity correlated with pain (p > 0.25). Conclusions

  19. Patients with vestibular loss, tullio phenomenon, and pressure-induced nystagmus: vestibular atelectasis?

    Science.gov (United States)

    Wenzel, Angela; Ward, Bryan K; Schubert, Michael C; Kheradmand, Amir; Zee, David S; Mantokoudis, Georgios; Carey, John Patrick

    2014-06-01

    To propose an etiology for a syndrome of bilateral vestibular hypofunction and sound and/or pressure-evoked eye movements with normal hearing thresholds. Retrospective case series. Tertiary care referral center. Four patients with bilateral vestibular hypofunction, sound and/or pressure-evoked nystagmus and normal hearing thresholds were identified over a 3-year period. No evidence of other known vestibular disorders was identified. None of these patients presented with a history of exposure to toxins, radiation, aminoglycosides or chemotherapy; head trauma; or a family history of inherited vestibular loss. All patients underwent high-resolution CT scan of the temporal bones to evaluate for labyrinthine dehiscence. Additionally, all individuals underwent audiometric testing to ANSI standards, vestibular-evoked myogenic potentials (VEMP) testing using either click stimulus cervical VEMPs (cVEMPs), or tone burst ocular VEMPs (oVEMPs). Bithermal caloric stimulation was used to measure horizontal semicircular canal function, with either videonystagmography (VNG) or electronystagmography (ENG) to record eye movements. Individual responses of each of the 6 semicircular canals (SCC) to rapid head rotations were tested with the bedside head impulse test. We identified 4 patients with a combination of bilateral vestibular hypofunction and sound and/or pressure-induced eye movements, normal-hearing thresholds and no evidence for any other vestibular disorder. We suggest that this unique combination of symptoms should be considered as the clinical presentation of vestibular atelectasis, which has been previously described histologically as collapse of the endolymph-containing portions of the labyrinth.

  20. High frequency oscillations evoked by peripheral magnetic stimulation.

    Science.gov (United States)

    Biller, S; Simon, L; Fiedler, P; Strohmeier, D; Haueisen, J

    2011-01-01

    The analysis of somatosensory evoked potentials (SEP) and / or fields (SEF) is a well-established and important tool for investigating the functioning of the peripheral and central human nervous system. A standard technique to evoke SEPs / SEFs is the stimulation of the median nerve by using a bipolar electrical stimulus. We aim at an alternative stimulation technique enabling stimulation of deep nerve structures while reducing patient stress and error susceptibility. In the current study, we apply a commercial transcranial magnetic stimulation system for peripheral magnetic stimulation of the median nerve. We compare the results of simultaneously recorded EEG signals to prove applicability of our technique to evoke SEPs including low frequency components (LFC) as well as high frequency oscillations (HFO). Therefore, we compare amplitude, latency and time-frequency characteristics of the SEP of 14 healthy volunteers after electric and magnetic stimulation. Both low frequency components and high frequency oscillations were detected. The HFOs were superimposed onto the primary cortical response N20. Statistical analysis revealed significantly lower amplitudes and increased latencies for LFC and HFO components after magnetic stimulation. The differences indicate the inability of magnetic stimulation to elicit supramaximal responses. A psycho-perceptual evaluation showed that magnetic stimulation was less unpleasant for 12 out of the 14 volunteers. In conclusion, we showed that LFC and HFO components related to median nerve stimulation can be evoked by peripheral magnetic stimulation.

  1. Radial head dislocation during proximal radial shaft osteotomy.

    Science.gov (United States)

    Hazel, Antony; Bindra, Randy R

    2014-03-01

    The following case report describes a 48-year-old female patient with a longstanding both-bone forearm malunion, who underwent osteotomies of both the radius and ulna to improve symptoms of pain and lack of rotation at the wrist. The osteotomies were templated preoperatively. During surgery, after performing the planned radial shaft osteotomy, the authors recognized that the radial head was subluxated. The osteotomy was then revised from an opening wedge to a closing wedge with improvement of alignment and rotation. The case report discusses the details of the operation, as well as ways in which to avoid similar shortcomings in the future. Copyright © 2014 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  2. Integration of visual and non-visual self-motion cues during voluntary head movements in the human brain.

    Science.gov (United States)

    Schindler, Andreas; Bartels, Andreas

    2018-05-15

    Our phenomenological experience of the stable world is maintained by continuous integration of visual self-motion with extra-retinal signals. However, due to conventional constraints of fMRI acquisition in humans, neural responses to visuo-vestibular integration have only been studied using artificial stimuli, in the absence of voluntary head-motion. We here circumvented these limitations and let participants to move their heads during scanning. The slow dynamics of the BOLD signal allowed us to acquire neural signal related to head motion after the observer's head was stabilized by inflatable aircushions. Visual stimuli were presented on head-fixed display goggles and updated in real time as a function of head-motion that was tracked using an external camera. Two conditions simulated forward translation of the participant. During physical head rotation, the congruent condition simulated a stable world, whereas the incongruent condition added arbitrary lateral motion. Importantly, both conditions were precisely matched in visual properties and head-rotation. By comparing congruent with incongruent conditions we found evidence consistent with the multi-modal integration of visual cues with head motion into a coherent "stable world" percept in the parietal operculum and in an anterior part of parieto-insular cortex (aPIC). In the visual motion network, human regions MST, a dorsal part of VIP, the cingulate sulcus visual area (CSv) and a region in precuneus (Pc) showed differential responses to the same contrast. The results demonstrate for the first time neural multimodal interactions between precisely matched congruent versus incongruent visual and non-visual cues during physical head-movement in the human brain. The methodological approach opens the path to a new class of fMRI studies with unprecedented temporal and spatial control over visuo-vestibular stimulation. Copyright © 2018 Elsevier Inc. All rights reserved.

  3. Trunk- and head-centred spatial coordinates do not affect free-viewing perceptual asymmetries.

    Science.gov (United States)

    Nicholls, Michael E R; Mattingley, Jason B; Bradshaw, John L; Krins, Phillip W

    2003-11-01

    Turning the trunk or head to the left can reduce the severity of leftward neglect. This study sought to determine whether turning the trunk or head to the right would reduce pseudoneglect: A phenomenon where normal participants underestimate the rightward features of a stimulus. Participants made luminance judgements of two mirror-reversed greyscales stimuli. A preference for selecting the stimulus dark on the left was found. The effect of trunk-centred coordinates was examined in Expt. 1 by facing the head toward the display and turning the trunk to the left, right or toward the display. Head-centred coordinates were examined in Expt. 2 by directing the eyes toward the display and then turning the head and trunk. No effect of rotation was observed. It was concluded that the leftward bias for the greyscales task could be based on an object-centred attentional bias or left-to-right eye scanning habits.

  4. Steady-state evoked potentials possibilities for mental-state estimation

    Science.gov (United States)

    Junker, Andrew M.; Schnurer, John H.; Ingle, David F.; Downey, Craig W.

    1988-01-01

    The use of the human steady-state evoked potential (SSEP) as a possible measure of mental-state estimation is explored. A method for evoking a visual response to a sum-of-ten sine waves is presented. This approach provides simultaneous multiple frequency measurements of the human EEG to the evoking stimulus in terms of describing functions (gain and phase) and remnant spectra. Ways in which these quantities vary with the addition of performance tasks (manual tracking, grammatical reasoning, and decision making) are presented. Models of the describing function measures can be formulated using systems engineering technology. Relationships between model parameters and performance scores during manual tracking are discussed. Problems of unresponsiveness and lack of repeatability of subject responses are addressed in terms of a need for loop closure of the SSEP. A technique to achieve loop closure using a lock-in amplifier approach is presented. Results of a study designed to test the effectiveness of using feedback to consciously connect humans to their evoked response are presented. Findings indicate that conscious control of EEG is possible. Implications of these results in terms of secondary tasks for mental-state estimation and brain actuated control are addressed.

  5. Relative plan robustness of step-and-shoot vs rotational intensity–modulated radiotherapy on repeat computed tomographic simulation for weight loss in head and neck cancer

    Energy Technology Data Exchange (ETDEWEB)

    Thomson, David J. [Department of Clinical Oncology, The Christie NHS Foundation Trust, Manchester (United Kingdom); The University of Manchester, Manchester Academic Health Science Centre, Institute of Cancer Sciences, Manchester (United Kingdom); Beasley, William J. [The University of Manchester, Manchester Academic Health Science Centre, Institute of Cancer Sciences, Manchester (United Kingdom); Christie Medical Physics and Engineering, The Christie NHS Foundation Trust, Manchester (United Kingdom); Garcez, Kate; Lee, Lip W.; Sykes, Andrew J. [Department of Clinical Oncology, The Christie NHS Foundation Trust, Manchester (United Kingdom); Rowbottom, Carl G. [The University of Manchester, Manchester Academic Health Science Centre, Institute of Cancer Sciences, Manchester (United Kingdom); Christie Medical Physics and Engineering, The Christie NHS Foundation Trust, Manchester (United Kingdom); Slevin, Nicholas J., E-mail: nick.slevin@christie.nhs.uk [Department of Clinical Oncology, The Christie NHS Foundation Trust, Manchester (United Kingdom); The University of Manchester, Manchester Academic Health Science Centre, Institute of Cancer Sciences, Manchester (United Kingdom)

    2016-07-01

    Introduction: Interfractional anatomical alterations may have a differential effect on the dose delivered by step-and-shoot intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT). The increased degrees of freedom afforded by rotational delivery may increase plan robustness (measured by change in target volume coverage and doses to organs at risk [OARs]). However, this has not been evaluated for head and neck cancer. Materials and methods: A total of 10 patients who required repeat computed tomography (CT) simulation and replanning during head and neck IMRT were included. Step-and-shoot IMRT and VMAT plans were generated from the original planning scan. The initial and second CT simulation scans were fused and targets/OAR contours transferred, reviewed, and modified. The plans were applied to the second CT scan and doses recalculated without repeat optimization. Differences between step-and-shoot IMRT and VMAT for change in target volume coverage and doses to OARs between first and second CT scans were compared by Wilcoxon signed rank test. Results: There were clinically relevant dosimetric changes between the first and the second CT scans for both the techniques (reduction in mean D{sub 95%} for PTV2 and PTV3, D{sub min} for CTV2 and CTV3, and increased mean doses to the parotid glands). However, there were no significant differences between step-and-shoot IMRT and VMAT for change in any target coverage parameter (including D{sub 95%} for PTV2 and PTV3 and D{sub min} for CTV2 and CTV3) or dose to any OARs (including parotid glands) between the first and the second CT scans. Conclusions: For patients with head and neck cancer who required replanning mainly due to weight loss, there were no significant differences in plan robustness between step-and-shoot IMRT and VMAT. This information is useful with increased clinical adoption of VMAT.

  6. Odor-evoked inhibition of olfactory sensory neurons drives olfactory perception in Drosophila.

    Science.gov (United States)

    Cao, Li-Hui; Yang, Dong; Wu, Wei; Zeng, Xiankun; Jing, Bi-Yang; Li, Meng-Tong; Qin, Shanshan; Tang, Chao; Tu, Yuhai; Luo, Dong-Gen

    2017-11-07

    Inhibitory response occurs throughout the nervous system, including the peripheral olfactory system. While odor-evoked excitation in peripheral olfactory cells is known to encode odor information, the molecular mechanism and functional roles of odor-evoked inhibition remain largely unknown. Here, we examined Drosophila olfactory sensory neurons and found that inhibitory odors triggered outward receptor currents by reducing the constitutive activities of odorant receptors, inhibiting the basal spike firing in olfactory sensory neurons. Remarkably, this odor-evoked inhibition of olfactory sensory neurons elicited by itself a full range of olfactory behaviors from attraction to avoidance, as did odor-evoked olfactory sensory neuron excitation. These results indicated that peripheral inhibition is comparable to excitation in encoding sensory signals rather than merely regulating excitation. Furthermore, we demonstrated that a bidirectional code with both odor-evoked inhibition and excitation in single olfactory sensory neurons increases the odor-coding capacity, providing a means of efficient sensory encoding.

  7. Norepinephrine-evoked pain in fibromyalgia. A randomized pilot study [ISRCTN70707830

    Directory of Open Access Journals (Sweden)

    Casanova Jose-Miguel

    2002-01-01

    Full Text Available Abstract Background Fibromyalgia syndrome displays sympathetically maintained pain features such as frequent post-traumatic onset and stimuli-independent pain accompanied by allodynia and paresthesias. Heart rate variability studies showed that fibromyalgia patients have changes consistent with ongoing sympathetic hyperactivity. Norepinephrine-evoked pain test is used to assess sympathetically maintained pain syndromes. Our objective was to define if fibromyalgia patients have norepinephrine-evoked pain. Methods Prospective double blind controlled study. Participants: Twenty FM patients, and two age/sex matched control groups; 20 rheumatoid arthritis patients and 20 healthy controls. Ten micrograms of norepinephrine diluted in 0.1 ml of saline solution were injected in a forearm. The contrasting substance, 0.1 ml of saline solution alone, was injected in the opposite forearm. Maximum local pain elicited during the 5 minutes post-injection was graded on a visual analog scale (VAS. Norepinephrine-evoked pain was diagnosed when norepinephrine injection induced greater pain than placebo injection. Intensity of norepinephrine-evoked pain was calculated as the difference between norepinephrine minus placebo-induced VAS scores. Results Norepinephrine-evoked pain was seen in 80 % of FM patients (95% confidence intervals 56.3 – 94.3%, in 30 % of rheumatoid arthritis patients and in 30 % of healthy controls (95% confidence intervals 11.9 – 54.3 (p Conclusions Fibromyalgia patients have norepinephrine-evoked pain. This finding supports the hypothesis that fibromyalgia may be a sympathetically maintained pain syndrome.

  8. Objective correlate of subjective pain perception by contact heat-evoked potentials.

    Science.gov (United States)

    Granovsky, Yelena; Granot, Michal; Nir, Rony-Reuven; Yarnitsky, David

    2008-01-01

    The method of pain-evoked potentials has gained considerable acceptance over the last 3 decades regarding its objectivity, repeatability, and quantifiability. The present study explored whether the relationship between pain-evoked potentials and pain psychophysics obtained by contact heat stimuli is similar to those observed for the conventionally used laser stimulation. Evoked potentials (EPs) were recorded in response to contact heat stimuli at different body sites in 24 healthy volunteers. Stimuli at various temperatures were applied to the forearm (43 degrees C, 46 degrees C, 49 degrees C, and 52 degrees C) and leg (46 degrees C and 49 degrees C). The amplitudes of both components (N2 and P2) were strongly associated with the intensity of the applied stimuli and with subjective pain perception. Yet, regression analysis revealed pain perception and not stimulus intensity as the major contributing factor. A significant correlation was found between the forearm and the leg for both psychophysics and EPs amplitude. Contact heat can generate readily distinguishable evoked potentials on the scalp, consistent between upper and lower limbs. Although these potentials bear positive correlation with both stimulus intensity and pain magnitude, the latter is the main contributor to the evoked brain response.

  9. Effects of single cycle binaural beat duration on auditory evoked potentials.

    Science.gov (United States)

    Mihajloski, Todor; Bohorquez, Jorge; Özdamar, Özcan

    2014-01-01

    Binaural beat (BB) illusions are experienced as continuous central pulsations when two sounds with slightly different frequencies are delivered to each ear. It has been shown that steady-state auditory evoked potentials (AEPs) to BBs can be captured and investigated. The authors recently developed a new method of evoking transient AEPs to binaural beats using frequency modulated stimuli. This methodology was able to create single BBs in predetermined intervals with varying carrier frequencies. This study examines the effects of the BB duration and the frequency modulating component of the stimulus on the binaural beats and their evoked potentials. Normal hearing subjects were tested with a set of four durations (25, 50, 100, and 200 ms) with two stimulation configurations, binaural dichotic (binaural beats) and diotic (frequency modulation). The results obtained from the study showed that out of the given durations, the 100 ms beat, was capable of evoking the largest amplitude responses. The frequency modulation effect showed a decrease in peak amplitudes with increasing beat duration until their complete disappearance at 200 ms. Even though, at 200 ms, the frequency modulation effects were not present, the binaural beats were still perceived and captured as evoked potentials.

  10. Effect of Putting Grip on Eye and Head Movements During the Golf Putting Stroke

    Directory of Open Access Journals (Sweden)

    George K. Hung

    2003-01-01

    Full Text Available The objective of this article is to determine the effect of three different putting grips (conventional, cross-hand, and one-handed on variations in eye and head movements during the putting stroke. Seven volunteer novice players, ranging in age from 21 to 22 years, participated in the study. During each experimental session, the subject stood on a specially designed platform covered with artificial turf and putted golf balls towards a standard golf hole. The three different types of grips were tested at two distances: 3 and 9 ft. For each condition, 20 putts were attempted. For each putt, data were recorded over a 3-s interval at a sampling rate of 100 Hz. Eye movements were recorded using a helmet-mounted eye movement monitor. Head rotation about an imaginary axis through the top of the head and its center-of-rotation was measured by means of a potentiometer mounted on a fixed frame and coupled to the helmet. Putter-head motion was measured using a linear array of infrared phototransistors embedded in the platform. The standard deviation (STD, relative to the initial level was calculated for eye and head movements over the duration of the putt (i.e., from the beginning of the backstroke, through the forward stroke, to impact. The averaged STD for the attempted putts was calculated for each subject. Then, the averaged STDs and other data for the seven subjects were statistically compared across the three grip conditions. The STD of eye movements were greater (p < 0.1 for conventional than cross-hand (9 ft and one-handed (3 and 9 ft grips. Also, the STD of head movements were greater (p < 0.1; 3 ft for conventional than cross-hand and one-handed grips. Vestibulo-ocular responses associated with head rotations could be observed in many 9 ft and some 3 ft putts. The duration of the putt was significantly longer (p < 0.05; 3 and 9 ft for the one-handed than conventional and cross-hand grips. Finally, performance, or percentage putts made, was

  11. Humor drawings evoked temporal and spectral EEG processes

    Science.gov (United States)

    Kuo, Hsien-Chu; Chuang, Shang-Wen

    2017-01-01

    Abstract The study aimed to explore the humor processing elicited through the manipulation of artistic drawings. Using the Comprehension–Elaboration Theory of humor as the main research background, the experiment manipulated the head portraits of celebrities based on the independent variables of facial deformation (large/small) and addition of affective features (positive/negative). A 64-channel electroencephalography was recorded in 30 participants while viewing the incongruous drawings of celebrities. The electroencephalography temporal and spectral responses were measured during the three stages of humor which included incongruity detection, incongruity comprehension and elaboration of humor. Analysis of event-related potentials indicated that for humorous vs non-humorous drawings, facial deformation and the addition of affective features significantly affected the degree of humor elicited, specifically: large > small deformation; negative > positive affective features. The N170, N270, N400, N600-800 and N900-1200 components showed significant differences, particularly in the right prefrontal and frontal regions. Analysis of event-related spectral perturbation showed significant differences in the theta band evoked in the anterior cingulate cortex, parietal region and posterior cingulate cortex; and in the alpha and beta bands in the motor areas. These regions are involved in emotional processing, memory retrieval, and laughter and feelings of amusement induced by elaboration of the situation. PMID:28402573

  12. Humor drawings evoked temporal and spectral EEG processes.

    Science.gov (United States)

    Wang, Regina W Y; Kuo, Hsien-Chu; Chuang, Shang-Wen

    2017-08-01

    The study aimed to explore the humor processing elicited through the manipulation of artistic drawings. Using the Comprehension-Elaboration Theory of humor as the main research background, the experiment manipulated the head portraits of celebrities based on the independent variables of facial deformation (large/small) and addition of affective features (positive/negative). A 64-channel electroencephalography was recorded in 30 participants while viewing the incongruous drawings of celebrities. The electroencephalography temporal and spectral responses were measured during the three stages of humor which included incongruity detection, incongruity comprehension and elaboration of humor. Analysis of event-related potentials indicated that for humorous vs non-humorous drawings, facial deformation and the addition of affective features significantly affected the degree of humor elicited, specifically: large > small deformation; negative > positive affective features. The N170, N270, N400, N600-800 and N900-1200 components showed significant differences, particularly in the right prefrontal and frontal regions. Analysis of event-related spectral perturbation showed significant differences in the theta band evoked in the anterior cingulate cortex, parietal region and posterior cingulate cortex; and in the alpha and beta bands in the motor areas. These regions are involved in emotional processing, memory retrieval, and laughter and feelings of amusement induced by elaboration of the situation. © The Author (2017). Published by Oxford University Press.

  13. Self locking drive system for rotating plug of a nuclear reactor

    International Nuclear Information System (INIS)

    Brubaker, J.E.

    1979-01-01

    A self locking drive system for rotating the plugs on the head of a nuclear reactor which is able to restrain plug motion if a seismic event whould occur during reactor refueling is described. A servomotor is engaged via a gear train and a bull gear to the plug. Connected to the gear train is a feedback control system which allows the motor to rotate the plug to predetermined locations for refueling of the reactor. The gear train contains a self locking double enveloping worm gear set. The worm gear set is utilized for its self locking nature to prevent unwanted rotation of the plugs as the result of an earthquake. The double enveloping type is used because its unique contour spreads the load across several teeth providing added strength and allowing the use of a conventional size worm

  14. Defining the biomechanical and biological threshold of murine mild traumatic brain injury using CHIMERA (Closed Head Impact Model of Engineered Rotational Acceleration).

    Science.gov (United States)

    Namjoshi, Dhananjay R; Cheng, Wai Hang; Bashir, Asma; Wilkinson, Anna; Stukas, Sophie; Martens, Kris M; Whyte, Tom; Abebe, Zelalem A; McInnes, Kurt A; Cripton, Peter A; Wellington, Cheryl L

    2017-06-01

    CHIMERA (Closed Head Impact Model of Engineered Rotational Acceleration) is a recently described animal model of traumatic brain injury (TBI) that primarily produces diffuse axonal injury (DAI) characterized by white matter inflammation and axonal damage. CHIMERA was specifically designed to reliably generate a variety of TBI severities using precise and quantifiable biomechanical inputs in a nonsurgical user-friendly platform. The objective of this study was to define the lower limit of single impact mild TBI (mTBI) using CHIMERA by characterizing the dose-response relationship between biomechanical input and neurological, behavioral, neuropathological and biochemical outcomes. Wild-type male mice were subjected to a single CHIMERA TBI using six impact energies ranging from 0.1 to 0.7J, and post-TBI outcomes were assessed over an acute period of 14days. Here we report that single TBI using CHIMERA induces injury dose- and time-dependent changes in behavioral and neurological deficits, axonal damage, white matter tract microgliosis and astrogliosis. Impact energies of 0.4J or below produced no significant phenotype (subthreshold), 0.5J led to significant changes for one or more phenotypes (threshold), and 0.6 and 0.7J resulted in significant changes in all outcomes assessed (mTBI). We further show that linear head kinematics are the most robust predictors of duration of unconsciousness, severity of neurological deficits, white matter injury, and microgliosis following single TBI. Our data extend the validation of CHIMERA as a biofidelic animal model of DAI and establish working parameters to guide future investigations of the mechanisms underlying axonal pathology and inflammation induced by mechanical trauma. Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.

  15. Instrumented mouthguard acceleration analyses for head impacts in amateur rugby union players over a season of matches.

    Science.gov (United States)

    King, Doug; Hume, Patria A; Brughelli, Matt; Gissane, Conor

    2015-03-01

    Direct impacts with the head (linear acceleration or pressure) and inertial loading of the head (rotational acceleration or strain) have been postulated as the 2 major mechanisms of head-related injuries such as concussion. Although data are accumulating for soccer and American football, there are no published data for nonhelmeted collision sports such as rugby union. To quantify head impacts via instrumented mouthguard acceleration analyses for rugby union players over a season of matches. Descriptive epidemiology study. Data on impact magnitude and frequency were collected with molded instrumented mouthguards worn by 38 premier amateur senior rugby players participating in the 2013 domestic season of matches. A total of 20,687 impacts >10g (range, 10.0-164.9g) were recorded over the duration of the study. The mean ± SD number of impacts per player over the duration of the season of matches was 564 ± 618, resulting in a mean ± SD of 95 ± 133 impacts to the head per player, per match over the duration of the season of matches. The impact magnitudes for linear accelerations were skewed to the lower values (Sp = 3.7 ± 0.02; P rugby union players over a season of matches, measured via instrumented mouthguard accelerations, were higher than for most sports previously reported. Mean linear acceleration measured over a season of matches was similar to the mean linear accelerations previously reported for youth, high school, and collegiate American football players but lower than that for female youth soccer players. Mean rotational acceleration measured over a season of matches was similar to mean rotational accelerations for youth, high school, and collegiate American football players but less than those for female youth soccer players, concussed American collegiate players, collegiate American football players, and professional American football players. © 2014 The Author(s).

  16. Dynamic Three-Dimensional Shoulder Mri during Active Motion for Investigation of Rotator Cuff Diseases.

    Directory of Open Access Journals (Sweden)

    Christine Tempelaere

    Full Text Available MRI is the standard methodology in diagnosis of rotator cuff diseases. However, many patients continue to have pain despite treatment, and MRI of a static unloaded shoulder seems insufficient for best diagnosis and treatment. This study evaluated if Dynamic MRI provides novel kinematic data that can be used to improve the understanding, diagnosis and best treatment of rotator cuff diseases.Dynamic MRI provided real-time 3D image series and was used to measure changes in the width of subacromial space, superior-inferior translation and anterior-posterior translation of the humeral head relative to the glenoid during active abduction. These measures were investigated for consistency with the rotator cuff diseases classifications from standard MRI.The study included: 4 shoulders with massive rotator cuff tears, 5 shoulders with an isolated full-thickness supraspinatus tear, 5 shoulders with tendinopathy and 6 normal shoulders. A change in the width of subacromial space greater than 4mm differentiated between rotator cuff diseases with tendon tears (massive cuff tears and supraspinatus tear and without tears (tendinopathy (p = 0.012. The range of the superior-inferior translation was higher in the massive cuff tears group (6.4mm than in normals (3.4mm (p = 0.02. The range of the anterior-posterior translation was higher in the massive cuff tears (9.2 mm and supraspinatus tear (9.3 mm shoulders compared to normals (3.5mm and tendinopathy (4.8mm shoulders (p = 0.05.The Dynamic MRI enabled a novel measure; 'Looseness', i.e. the translation of the humeral head on the glenoid during an abduction cycle. Looseness was better able at differentiating different forms of rotator cuff disease than a simple static measure of relative glenohumeral position.

  17. Head-head interactions of resting myosin crossbridges in intact frog skeletal muscles, revealed by synchrotron x-ray fiber diffraction.

    Directory of Open Access Journals (Sweden)

    Kanji Oshima

    Full Text Available The intensities of the myosin-based layer lines in the x-ray diffraction patterns from live resting frog skeletal muscles with full thick-thin filament overlap from which partial lattice sampling effects had been removed were analyzed to elucidate the configurations of myosin crossbridges around the thick filament backbone to nanometer resolution. The repeat of myosin binding protein C (C-protein molecules on the thick filaments was determined to be 45.33 nm, slightly longer than that of myosin crossbridges. With the inclusion of structural information for C-proteins and a pre-powerstroke head shape, modeling in terms of a mixed population of regular and perturbed regions of myosin crown repeats along the filament revealed that the myosin filament had azimuthal perturbations of crossbridges in addition to axial perturbations in the perturbed region, producing pseudo-six-fold rotational symmetry in the structure projected down the filament axis. Myosin crossbridges had a different organization about the filament axis in each of the regular and perturbed regions. In the regular region that lacks C-proteins, there were inter-molecular interactions between the myosin heads in axially adjacent crown levels. In the perturbed region that contains C-proteins, in addition to inter-molecular interactions between the myosin heads in the closest adjacent crown levels, there were also intra-molecular interactions between the paired heads on the same crown level. Common features of the interactions in both regions were interactions between a portion of the 50-kDa-domain and part of the converter domain of the myosin heads, similar to those found in the phosphorylation-regulated invertebrate myosin. These interactions are primarily electrostatic and the converter domain is responsible for the head-head interactions. Thus multiple head-head interactions of myosin crossbridges also characterize the switched-off state and have an important role in the regulation

  18. An investigation of head movement with a view to minimising motion artefact during SPECT and PET imaging of the brain

    International Nuclear Information System (INIS)

    Patterson, H.; Clarke, G.H.; Guy, R.; McKay, W.J.

    1998-01-01

    Full text: Motion artefact has long been recognised as a major cause of image degradation. Single Photon Emission Computerised Tomography (SPECT) and Positron Emission Tomography (PET) of the brain are playing an important role in the diagnosis and management of several neurological disorders. If these imaging modalities are to contribute fully to medical imaging it is essential that the improved spatial resolution of these systems is not compromised by patient movement. Thirty volunteer subjects have been examined using a simple video technique and the video images were used to classify and measure head movements which may occur during brain imaging. All subjects demonstrated angular movement within the transverse plane or rotation of the head. Angular movement within the sagittal plane or flexion/extension of the neck occurred in 69% of subjects and 72% of subjects exhibited translational movement of the sagittal plane. There was no movement of the coronal plane; nor was there any translational movement of the sagittal plane. These results suggest that when positioning the patient's head for brain imaging a system of head restraint which minimises rotation of the head should be used if image quality is to be maintained

  19. The role of pectoralis major and latissimus dorsi muscles in a biomechanical model of massive rotator cuff tear.

    Science.gov (United States)

    Campbell, Sean T; Ecklund, Kier J; Chu, Eileen H; McGarry, Michelle H; Gupta, Ranjan; Lee, Thay Q

    2014-08-01

    Superior migration of the humeral head after massive rotator cuff tear (mRCT) is thought to lead to cuff tear arthropathy. Previous biomechanical studies have demonstrated the ability of the pectoralis major and latissimus dorsi (PM/LD) muscles to resist this migration. This study examined the role of PM/LD muscles on glenohumeral joint forces and acromiohumeral contact pressures in a mRCT model. Six cadaveric shoulders were tested using a custom shoulder-testing system. Muscle insertions of the rotator cuff, deltoid, and PM/LD were preserved and used for muscle loading. Specimens were tested in 3 different humeral rotation positions at 0° abduction and 2 rotation positions at 60° abduction. Testing was performed for intact specimens, after supraspinatus removal, and after supraspinatus/infraspinatus/teres minor removal. PM/LD were loaded or unloaded to determine their effect. Humeral head kinematics, glenohumeral joint forces, and acromiohumeral contact area and pressure were measured. For the mRCT condition at 0° abduction, unloading the PM/LD resulted in superior shift of the humeral head. Acromiohumeral contact pressures were undetectable when the PM/LD were loaded but increased significantly after PM/LD unloading. After mRCT, superior joint forces were increased and compressive forces were decreased compared with intact; loading the PM/LD resolved these abnormal forces in some testing conditions. In mRCT, the PM and LD muscles are effective in improving glenohumeral kinematics and reducing acromiohumeral pressures. Strengthening or neuromuscular training of this musculature, or both, may delay the progression to cuff tear arthropathy. Published by Mosby, Inc.

  20. Weak rotating flow disturbances in a centrifugal compressor with a vaneless diffuser

    Science.gov (United States)

    Moore, F. K.

    1988-01-01

    A theory is presented to predict the occurrence of weak rotating waves in a centrifugal compression system with a vaneless diffuser. As in a previous study of axial systems, an undisturbed performance characteristic is assumed known. Following an inviscid analysis of the diffuser flow, conditions for a neutral rotating disturbance are found. The solution is shown to have two branches; one with fast rotation, the other with very slow rotation. The slow branch includes a dense set of resonant solutions. The resonance is a feature of the diffuser flow, and therefore such disturbances must be expected at the various resonant flow coefficients regardless of the compressor characteristic. Slow solutions seem limited to flow coefficients less than about 0.3, where third and fourth harmonics appear. Fast waves seem limited to a first harmonic. These fast and slow waves are described, and effects of diffuser-wall convergence, backward blade angles, and partial recovery of exit velocity head are assessed.

  1. Effect of radial head implant shape on joint contact area and location during static loading.

    Science.gov (United States)

    Shannon, Hannah L; Deluce, Simon R; Lalone, Emily A; Willing, Ryan; King, Graham J W; Johnson, James A

    2015-04-01

    To examine the effect of implant shape on radiocapitellar joint contact area and location in vitro. We used 8 fresh-frozen cadaveric upper extremities. An elbow loading simulator examined joint contact in pronation, neutral rotation, and supination with the elbow at 90° flexion. Muscle tendons were attached to pneumatic actuators to allow for computer-controlled loading to achieve the desired forearm rotation. We performed testing with the native radial head, an axisymmetric implant, a reverse-engineered patient-specific implant, and a population-based quasi-anatomic implant. Implants were inserted using computer navigation. Contact area and location were quantified using a casting technique. We found no significant difference between contact locations for the native radial head and the 3 implants. All of the implants had a contact area lower than the native radial head; however, only the axisymmetric implant was significantly different. There was no significant difference in contact area between implant shapes. The similar contact areas and locations of the 3 implant designs suggest that the shape of the implant may not be important with respect to radiocapitellar joint contact mechanics when placed optimally using computer navigation. Further work is needed to explore the sensitivity of radial head implant malpositioning on articular contact. The lower contact area of the radial head implants relative to the native radial head is similar to previous benchtop studies and is likely the result of the greater stiffness of the implant. Radial head implant shape does not appear to have a pronounced influence on articular contact, and both axisymmetric and anatomic metal designs result in elevated cartilage stress relative to the intact state. Copyright © 2015 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  2. Manual of head and neck imaging

    International Nuclear Information System (INIS)

    Raghavan, Prashant; Mukherjee, Sugoto; Jameson, Mark J.; Wintermark, Max

    2014-01-01

    Easy-to-read short chapters. Tables, checklists, and algorithms to assist in arriving at a quick diagnosis. Clinical pearls that will enable the radiologist to issue a relevant report. One-stop resource when preparing for radiology and otolaryngology exams. Line diagrams to illustrate key concepts. This book is designed as an easily readable manual that will be of great practical value for radiology and otolaryngology residents during their clinical rotations. Key facts on head and neck imaging are presented in short chapters written in an easily readable style. Line drawings are used to illustrate key concepts, and tables, checklists, and algorithms will enable the readers to arrive at a quick diagnosis. In addition, emphasis is placed on clinical pearls that will assist them in preparing suitable reports. The Manual of Head and Neck Imaging is sized to allow residents to read it completely within a matter of days, and it will also serve as an ideal quick reference guide as different clinical situations arise.

  3. A Telehealth System for Remote Auditory Evoked Potential Monitoring

    OpenAIRE

    Millan, Jorge; Yunda, Leonardo

    2013-01-01

    A portable, Internet-based EEG/Auditory Evoked Potential (AEP) monitoring system was developed for remote electrophysiological studies during sleep. The system records EEG/AEP simultaneously at the subject?s home for increased comfort and flexibility. The system provides simultaneous recording and remote viewing of EEG, EMG and EOG waves and allows on-line averaging of auditory evoked potentials. The design allows the recording of all major AEP components (brainstem, middle and late latency E...

  4. The Role of Odor-Evoked Memory in Psychological and Physiological Health.

    Science.gov (United States)

    Herz, Rachel S

    2016-07-19

    This article discusses the special features of odor-evoked memory and the current state-of-the-art in odor-evoked memory research to show how these unique experiences may be able to influence and benefit psychological and physiological health. A review of the literature leads to the conclusion that odors that evoke positive autobiographical memories have the potential to increase positive emotions, decrease negative mood states, disrupt cravings, and reduce physiological indices of stress, including systemic markers of inflammation. Olfactory perception factors and individual difference characteristics that would need to be considered in therapeutic applications of odor-evoked-memory are also discussed. This article illustrates how through the experimentally validated mechanisms of odor-associative learning and the privileged neuroanatomical relationship that exists between olfaction and the neural substrates of emotion, odors can be harnessed to induce emotional and physiological responses that can improve human health and wellbeing.

  5. The Role of Odor-Evoked Memory in Psychological and Physiological Health

    Directory of Open Access Journals (Sweden)

    Rachel S. Herz

    2016-07-01

    Full Text Available This article discusses the special features of odor-evoked memory and the current state-of-the-art in odor-evoked memory research to show how these unique experiences may be able to influence and benefit psychological and physiological health. A review of the literature leads to the conclusion that odors that evoke positive autobiographical memories have the potential to increase positive emotions, decrease negative mood states, disrupt cravings, and reduce physiological indices of stress, including systemic markers of inflammation. Olfactory perception factors and individual difference characteristics that would need to be considered in therapeutic applications of odor-evoked-memory are also discussed. This article illustrates how through the experimentally validated mechanisms of odor-associative learning and the privileged neuroanatomical relationship that exists between olfaction and the neural substrates of emotion, odors can be harnessed to induce emotional and physiological responses that can improve human health and wellbeing.

  6. Thought-evoking approaches in engineering problems

    CERN Document Server

    2014-01-01

    In creating the value-added product in not distant future, it is necessary and inevitable to establish a holistic and though-evoking approach to the engineering problem, which should be at least associated with the inter-disciplinary knowledge and thought processes across the whole engineering spheres. It is furthermore desirable to integrate it with trans-disciplinary aspects ranging from manufacturing culture, through liberal-arts engineering, and industrial sociology.   The thought-evoking approach can be exemplified and typified by representative engineering problems: unveiling essential features in ‘Tangential Force Ratio and Interface Pressure’, prototype development for ‘Bio-mimetic Needle’ and application of ‘Water-jet Machining to Artificial Hip Joint’, product innovation in ‘Heat Sink for Computer’, application of ‘Graph Theory’ to similarity evaluation of production systems, leverage among reciprocity attributes in ‘Industrial and Engineering Designs for Machine Enclosure’,...

  7. Speech-evoked auditory brainstem responses in children with hearing loss.

    Science.gov (United States)

    Koravand, Amineh; Al Osman, Rida; Rivest, Véronique; Poulin, Catherine

    2017-08-01

    The main objective of the present study was to investigate subcortical auditory processing in children with sensorineural hearing loss. Auditory Brainstem Responses (ABRs) were recorded using click and speech/da/stimuli. Twenty-five children, aged 6-14 years old, participated in the study: 13 with normal hearing acuity and 12 with sensorineural hearing loss. No significant differences were observed for the click-evoked ABRs between normal hearing and hearing-impaired groups. For the speech-evoked ABRs, no significant differences were found for the latencies of the following responses between the two groups: onset (V and A), transition (C), one of the steady-state wave (F), and offset (O). However, the latency of the steady-state waves (D and E) was significantly longer for the hearing-impaired compared to the normal hearing group. Furthermore, the amplitude of the offset wave O and of the envelope frequency response (EFR) of the speech-evoked ABRs was significantly larger for the hearing-impaired compared to the normal hearing group. Results obtained from the speech-evoked ABRs suggest that children with a mild to moderately-severe sensorineural hearing loss have a specific pattern of subcortical auditory processing. Our results show differences for the speech-evoked ABRs in normal hearing children compared to hearing-impaired children. These results add to the body of the literature on how children with hearing loss process speech at the brainstem level. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Neck Kinematics and Electromyography While Wearing Head Supported Mass During Running.

    Science.gov (United States)

    Hanks, Matthew M; Sefton, JoEllen M; Oliver, Gretchen D

    2018-01-01

    Advanced combat helmets (ACH) coupled with night-vision goggles (NVG) are required for tactical athletes during training and service. Head and neck injuries due to head supported mass (HSM) are a common occurrence in military personnel. The current study aimed to investigate the effects of HSM on neck muscle fatigue that may lead to chronic stress and injury of the head and neck. Subjects wore an ACH and were affixed with electromagnetic sensors to obtain kinematic data, as well as EMG electrodes to obtain muscle activations of bilateral sternocleidomastoid, upper trapezius, and paraspinal muscles while running on a treadmill. Subjects performed a 2-min warmup at a walking pace, a 5-min warmup jog, running at a pace equal to 90% maximum heart rate until absolute fatigue, and lastly a 2-min cooldown at a walking pace. Kinematic and EMG data were collected over each 2-min interval. Days later, the same subjects wore the same ACH in addition to the NVG and performed the same protocol as the first session. This study showed significant differences in muscle activation of the right upper trapezius [F(1,31) = 10.100] and both sternocleidomastoid [F(1,31) = 12.280] muscles from pre-fatigue to absolute fatigue. There were no significant differences noted in the kinematic variables. This study suggests that HSM can fatigue bilateral neck flexors and rotators, as well as fatigue the neck extensors and rotators on the contralateral side of the mounted NVG.Hanks MM, Sefton JM, Oliver GD. Neck kinematics and electromyography while wearing head supported mass during running. Aerosp Med Hum Perform. 2018; 89(1):9-13.

  9. Behavioral analyses of wind-evoked escape of the cricket, Gryllodes sigillatus.

    Science.gov (United States)

    Kanou, Masamichi; Konishi, Atsuko; Suenaga, Rie

    2006-04-01

    The wind-evoked escape behavior of the cricket Gryllodes sigillatus was investigated using an air puff stimulus. A high velocity air puff elicited the escape behavior in many crickets. The crickets tended to escape away from the stimulus source, but the direction was not accurately oriented 180 degrees from the stimulus. After bilateral cercal ablation, only a few crickets showed wind-evoked escape behavior, and their response rates did not increase even 19 days after ablation. Therefore, information on air motion detected by cercal filiform hairs is essential for triggering wind-evoked behavior. After unilateral cercal ablation, the 81.3% response rate of intact crickets decreased to 16.5%, that is, it decreased to almost 20% that of intact crickets. One week after unilateral cercal ablation, the response rate recovered to more than 60% that of intact crickets. However, the accuracy rate of the escape direction of G. sigillatus showed no change even immediately after the unilateral cercal ablation. Therefore, both cerci are not necessarily required to determine the escape direction. The behavioral characteristics of wind-evoked escape of G. sigillatus are compared with those of another species of cricket, Gryllus bimaculatus. The two species of cricket employ different strategies for wind-evoked escape.

  10. Effect of Subject Rotation on Assessment of Esthetic Dental Ratios: A Simulation Study

    Directory of Open Access Journals (Sweden)

    Rajesh Gyawali

    2016-01-01

    Full Text Available Objective. This study aimed to find out the change in esthetic ratios during rotation of patient’s head using a simulation. Materials and Methods. A plaster study model was photographed placing its midline along the long axis of the camera. Then a series of photographs were taken by rotating the model each degree till 10° on both right and left sides. These photographs were digitally measured and the ratio of the maxillary anterior teeth at zero-degree rotation was compared with that at various degrees of rotation. Results. As the model was rotated to the right side till 10°, the ratio of the right lateral to central incisor gradually decreased while the ratio of the left lateral to central incisor gradually increased. However, the ratio of the canine to lateral incisor on both sides gradually increased. Similar results were obtained when the model was rotated to the left side. The ratio of the lateral to central incisor deviated from the acceptable range (±10% when there was rotation of more than 7°, whereas the ratio of the canine to lateral incisor was within the acceptable range till 10° rotation on either side. Conclusions. Rotation of the model by more than 7° leads to a substantial change in the esthetic ratio.

  11. Three-dimensional display of femoral head cartilage thickness maps from MR images

    International Nuclear Information System (INIS)

    Rubin, R.A.; Dolecki, M.; Rubash, H.E.; Thaete, F.L.; Hernden, J.H.

    1990-01-01

    This paper reports on the development of methods for three-dimensional display and analysis of the articular cartilage of the hip from MR images. Cadaveric femoral head specimens were images with three-dimensional GRASS MR imaging. Data were analyzed on a SUN workstation with original software, the ANALYZE package from Richard Robb's Biomedical Research Group at the Mayo Clinic, and SUN's Voxvu program. The articular cartilage was isolated by manually segmenting images. An original computer ray tracing method measured the cartilage thickness radially and produced movies of a rotating femoral head, displaying brightness proportional to cartilage thickness

  12. First Metatarsal Head and Medial Eminence Widths with and Without Hallux Valgus.

    Science.gov (United States)

    Lenz, Robin C; Nagesh, Darshan; Park, Hannah K; Grady, John

    2016-09-02

    Resection of the medial eminence in hallux valgus surgery is common. True hypertrophy of the medial eminence in hallux valgus is debated. No studies have compared metatarsal head width in patients with hallux valgus and control patients. We reviewed 43 radiographs with hallux valgus and 27 without hallux valgus. We measured medial eminence width, first metatarsal head width, and first metatarsal shaft width in patients with and without radiographic hallux valgus. Medial eminence width was 1.12 mm larger in patients with hallux valgus (P hallux valgus (P hallux valgus. However, frontal plane rotation of the first metatarsal likely accounts for this difference.

  13. Skinfold thickness affects the isometric knee extension torque evoked by Neuromuscular Electrical Stimulation.

    Science.gov (United States)

    Medeiros, Flávia V A; Vieira, Amilton; Carregaro, Rodrigo L; Bottaro, Martim; Maffiuletti, Nicola A; Durigan, João L Q

    2015-01-01

    Subcutaneous adipose tissue may influence the transmission of electrical stimuli through to the skin, thus affecting both evoked torque and comfort perception associated with neuromuscular electrical stimulation (NMES). This could seriously affect the effectiveness of NMES for either rehabilitation or sports purposes. To investigate the effects of skinfold thickness (SFT) on maximal NMES current intensity, NMES-evoked torque, and NMES-induced discomfort. First, we compared NMES current intensity, NMES-induced discomfort, and NMES-evoked torque between two subgroups of subjects with thicker (n=10; 20.7 mm) vs. thinner (n=10; 29.4 mm) SFT. Second, we correlated SFT to NMES current intensity, NMES-induced discomfort, and NMES-evoked knee extension torque in 20 healthy women. The NMES-evoked torque was normalized to the maximal voluntary contraction (MVC) torque. The discomfort induced by NMES was assessed with a visual analog scale (VAS). NMES-evoked torque was 27.5% lower in subjects with thicker SFT (p=0.01) while maximal current intensity was 24.2% lower in subjects with thinner SFT (p=0.01). A positive correlation was found between current intensity and SFT (r=0.540, p=0.017). A negative correlation was found between NMES-evoked torque and SFT (r=-0.563, p=0.012). No significant correlation was observed between discomfort scores and SFT (rs=0.15, p=0.53). These results suggest that the amount of subcutaneous adipose tissue (as reflected by skinfold thickness) affected NMES current intensity and NMES-evoked torque, but had no effect on discomfort perception. Our findings may help physical therapists to better understand the impact of SFT on NMES and to design more rational stimulation strategies.

  14. Pharmacology of Bradykinin-Evoked Coughing in Guinea Pigs.

    Science.gov (United States)

    Hewitt, Matthew M; Adams, Gregory; Mazzone, Stuart B; Mori, Nanako; Yu, Li; Canning, Brendan J

    2016-06-01

    Bradykinin has been implicated as a mediator of the acute pathophysiological and inflammatory consequences of respiratory tract infections and in exacerbations of chronic diseases such as asthma. Bradykinin may also be a trigger for the coughing associated with these and other conditions. We have thus set out to evaluate the pharmacology of bradykinin-evoked coughing in guinea pigs. When inhaled, bradykinin induced paroxysmal coughing that was abolished by the bradykinin B2 receptor antagonist HOE 140. These cough responses rapidly desensitized, consistent with reports of B2 receptor desensitization. Bradykinin-evoked cough was potentiated by inhibition of both neutral endopeptidase and angiotensin-converting enzyme (with thiorphan and captopril, respectively), but was largely unaffected by muscarinic or thromboxane receptor blockade (atropine and ICI 192605), cyclooxygenase, or nitric oxide synthase inhibition (meclofenamic acid and N(G)-nitro-L-arginine). Calcium influx studies in bronchopulmonary vagal afferent neurons dissociated from vagal sensory ganglia indicated that the tachykinin-containing C-fibers arising from the jugular ganglia mediate bradykinin-evoked coughing. Also implicating the jugular C-fibers was the observation that simultaneous blockade of neurokinin2 (NK2; SR48968) and NK3 (SR142801 or SB223412) receptors nearly abolished the bradykinin-evoked cough responses. The data suggest that bradykinin induces coughing in guinea pigs by activating B2 receptors on bronchopulmonary C-fibers. We speculate that therapeutics targeting the actions of bradykinin may prove useful in the treatment of cough. Copyright © 2016 by The American Society for Pharmacology and Experimental Therapeutics.

  15. Do video games evoke specific types of epileptic seizures?

    Science.gov (United States)

    Piccioli, Marta; Vigevano, Federico; Buttinelli, Carla; Kasteleijn-Nolst Trenité, Dorothée G A

    2005-11-01

    We determined whether epileptic clinical manifestations evoked by playing video games (VG) differ from those evoked by intermittent photic stimulation (IPS) or striped patterns (P). We exposed nine children who had TV- and VG-evoked seizures in daily life to 12 VG after standardized photic stimulation and pattern stimulation. Their EEGs were recorded continuously, analyzed, and then correlated with a video of their behavior. Similar types of clinical signs were seen during VG, P, and IPS, but the signs we observed were more subtle during the VG. Eight patients showed a clear lateralization. A new observation was the lowering of the eyelids to a state of half-closed. Our study suggests that the type of visual stimulus provoking a photoparoxysmal response or seizure is not particularly relevant. The children belonged to different epilepsy groups, and our findings add to the discussion on the boundaries of the epilepsy types.

  16. Awareness during anaesthesia for surgery requiring evoked potential monitoring: A pilot study

    Directory of Open Access Journals (Sweden)

    Pritish J Korula

    2017-01-01

    Full Text Available Background: Evoked potential monitoring such as somatosensory-evoked potential (SSEP or motor-evoked potential (MEP monitoring during surgical procedures in proximity to the spinal cord requires minimising the minimum alveolar concentrations (MACs below the anaesthetic concentrations normally required (1 MAC to prevent interference in amplitude and latency of evoked potentials. This could result in awareness. Our primary objective was to determine the incidence of awareness while administering low MAC inhalational anaesthetics for these unique procedures. The secondary objective was to assess the adequacy of our anaesthetic technique from neurophysiologist′s perspective. Methods: In this prospective observational pilot study, 61 American Society of Anesthesiologists 1 and 2 patients undergoing spinal surgery for whom intraoperative evoked potential monitoring was performed were included; during the maintenance phase, 0.7-0.8 MAC of isoflurane was targeted. We evaluated the intraoperative depth of anaesthesia using a bispectral (BIS index monitor as well as the patients response to surgical stimulus (PRST scoring system. Post-operatively, a modified Bruce questionnaire was used to verify awareness. The adequacy of evoked potential readings was also assessed. Results: Of the 61 patients, no patient had explicit awareness. Intraoperatively, 19 of 61 patients had a BIS value of above sixty at least once, during surgery. There was no correlation with PRST scoring and BIS during surgery. Fifty-four out of 61 patient′s evoked potential readings were deemed ′good′ or ′fair′ for the conduct of electrophysiological monitoring. Conclusions: This pilot study demonstrates that administering low MAC inhalational anaesthetics to facilitate evoked potential monitoring does not result in explicit awareness. However, larger studies are needed to verify this. The conduct of SSEP electrophysiological monitoring was satisfactory with the use of this

  17. Sheep head frame validation for CT and MRI studies

    Directory of Open Access Journals (Sweden)

    marco trovatelli

    2017-05-01

    Full Text Available Abstract   Introductions Aim of EDEN 2020 project’s Milestone 5 is the development of a steerable catheter for CED system in glioblastoma therapy. The VET group is involved in realization and validation of the proper animal model. Materials and methods In this part of the study two fresh sheep’s head from the local slaughter were used. The heads were located into an ad hoc Frame system based on anatomical measures and CT images, producted by Renishaw plc partner in this project. The frame was adapted and every components were checked for the ex vivo validation tests. CT imaging was taken in Lodi at Università degli studi di Milano, Facoltà di Medicina Veterinaria, with CT scanner and MRI imaging was taken in La Cittadina, Cremona Results System validation was approved by the ex vivo trial. The frame system doesn’t compromise the imaging acquisition in MRI and CT systems. Every system components are functional to their aims. Discussion The Frame system is adapted to the sheep head. It is composed by elements able to lock the head during the imaging acquisition. Frame system is characterized by a support base helpings the animals to keep the head straight forward during imaging time, under general anesthesia. The design of these device support the airways anatomy, avoiding damaging or obstruction of airflows during anesthesia period. The role of elements like mouth bar and ovine head pins is to lock the head in a stable position during imaging acquisition; fixing is guaranteed by V shape head pins, that are arranged against the zygomatic arches. Lateral compression forces to the cranium, and the V shape pins avoid the vertical shifting of the head and any kind of rotations. (fig. 1

  18. Random Positional Variation Among the Skull, Mandible, and Cervical Spine With Treatment Progression During Head-and-Neck Radiotherapy

    International Nuclear Information System (INIS)

    Ahn, Peter H.; Ahn, Andrew I.; Lee, C. Joe; Shen Jin; Miller, Ekeni; Lukaj, Alex; Milan, Elissa; Yaparpalvi, Ravindra; Kalnicki, Shalom; Garg, Madhur K.

    2009-01-01

    Purpose: With 54 o of freedom from the skull to mandible to C7, ensuring adequate immobilization for head-and-neck radiotherapy (RT) is complex. We quantify variations in skull, mandible, and cervical spine movement between RT sessions. Methods and Materials: Twenty-three sequential head-and-neck RT patients underwent serial computed tomography. Patients underwent planned rescanning at 11, 22, and 33 fractions for a total of 93 scans. Coordinates of multiple bony elements of the skull, mandible, and cervical spine were used to calculate rotational and translational changes of bony anatomy compared with the original planning scan. Results: Mean translational and rotational variations on rescanning were negligible, but showed a wide range. Changes in scoliosis and lordosis of the cervical spine between fractions showed similar variability. There was no correlation between positional variation and fraction number and no strong correlation with weight loss or skin separation. Semi-independent rotational and translation movement of the skull in relation to the lower cervical spine was shown. Positioning variability measured by means of vector displacement was largest in the mandible and lower cervical spine. Conclusions: Although only small overall variations in position between head-and-neck RT sessions exist on average, there is significant random variation in patient positioning of the skull, mandible, and cervical spine elements. Such variation is accentuated in the mandible and lower cervical spine. These random semirigid variations in positioning of the skull and spine point to a need for improved immobilization and/or confirmation of patient positioning in RT of the head and neck

  19. Random Positional Variation Among the Skull, Mandible, and Cervical Spine With Treatment Progression During Head-and-Neck Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Peter H. [Department of Radiation Oncology, Montefiore Medical Center and Albert Einstein College of Medicine, Bronx, NY (United States)], E-mail: phahn@mdanderson.org; Ahn, Andrew I [Albert Einstein College of Medicine of Yeshiva University, Bronx, NY (United States); Lee, C Joe; Jin, Shen; Miller, Ekeni; Lukaj, Alex; Milan, Elissa; Yaparpalvi, Ravindra; Kalnicki, Shalom; Garg, Madhur K [Department of Radiation Oncology, Montefiore Medical Center and Albert Einstein College of Medicine, Bronx, NY (United States)

    2009-02-01

    Purpose: With 54{sup o} of freedom from the skull to mandible to C7, ensuring adequate immobilization for head-and-neck radiotherapy (RT) is complex. We quantify variations in skull, mandible, and cervical spine movement between RT sessions. Methods and Materials: Twenty-three sequential head-and-neck RT patients underwent serial computed tomography. Patients underwent planned rescanning at 11, 22, and 33 fractions for a total of 93 scans. Coordinates of multiple bony elements of the skull, mandible, and cervical spine were used to calculate rotational and translational changes of bony anatomy compared with the original planning scan. Results: Mean translational and rotational variations on rescanning were negligible, but showed a wide range. Changes in scoliosis and lordosis of the cervical spine between fractions showed similar variability. There was no correlation between positional variation and fraction number and no strong correlation with weight loss or skin separation. Semi-independent rotational and translation movement of the skull in relation to the lower cervical spine was shown. Positioning variability measured by means of vector displacement was largest in the mandible and lower cervical spine. Conclusions: Although only small overall variations in position between head-and-neck RT sessions exist on average, there is significant random variation in patient positioning of the skull, mandible, and cervical spine elements. Such variation is accentuated in the mandible and lower cervical spine. These random semirigid variations in positioning of the skull and spine point to a need for improved immobilization and/or confirmation of patient positioning in RT of the head and neck.

  20. Transmitter modulation of spike-evoked calcium transients in arousal related neurons

    DEFF Research Database (Denmark)

    Kohlmeier, Kristi Anne; Leonard, Christopher S

    2006-01-01

    Nitric oxide synthase (NOS)-containing cholinergic neurons in the laterodorsal tegmentum (LDT) influence behavioral and motivational states through their projections to the thalamus, ventral tegmental area and a brainstem 'rapid eye movement (REM)-induction' site. Action potential-evoked intracel......Nitric oxide synthase (NOS)-containing cholinergic neurons in the laterodorsal tegmentum (LDT) influence behavioral and motivational states through their projections to the thalamus, ventral tegmental area and a brainstem 'rapid eye movement (REM)-induction' site. Action potential......-evoked intracellular calcium transients dampen excitability and stimulate NO production in these neurons. In this study, we investigated the action of several arousal-related neurotransmitters and the role of specific calcium channels in these LDT Ca(2+)-transients by simultaneous whole-cell recording and calcium...... of cholinergic LDT neurons and that inhibition of spike-evoked Ca(2+)-transients is a common action of neurotransmitters that also activate GIRK channels in these neurons. Because spike-evoked calcium influx dampens excitability, our findings suggest that these 'inhibitory' transmitters could boost firing rate...

  1. Using a smartphone as a tool to measure compensatory and anomalous head positions.

    Science.gov (United States)

    Farah, Michelle de Lima; Santinello, Murillo; Carvalho, Luis Eduardo Morato Rebouças de; Uesugui, Carlos Fumiaki; Barcellos, Ronaldo Boaventura

    2018-01-01

    To describe a new method for measuring anomalous head positions by using a cell phone. The photo rotation feature of the iPhone® PHOTOS application was used. With the patient seated on a chair, a horizontal stripe was fixed on the wall in the background and a sagittal stripe was fixed on the seat. Photographs were obtained in the following views: front view (photographs A and B; with the head tilted over one shoulder) and upper axial view (photographs C and D; viewing the forehead and nose) (A and C are without camera rotation, and B and D are with camera rotation). A blank sheet of paper with two straight lines making a 32-degree angle was also photographed. Thirty examiners were instructed to measure the rotation required to align the reference points with the orthogonal axes. In order to set benchmarks to be compared with the measurements obtained by the examiners, blue lines were digitally added to the front and upper view photographs. In the photograph of the sheet of paper (p=0.380 and a=5%), the observed values did not differ statistically from the known value of 32 degrees. Mean measurements were as follows: front view photograph A, 22.8 ± 2.77; front view B, 21.4 ± 1.61; upper view C, 19.6 ± 2.36; and upper view D, 20.1 ± 2.33 degrees. The mean difference in measurements for the front view photograph A was -1.88 (95% CI -2.88 to -0.88), front view B was -0.37 (95% CI -0.97 to 0.17), upper view C was 1.43 (95% CI 0.55 to 2.24), and upper view D was 1.87 (95% CI 1.02 to 2.77). The method used in this study for measuring anomalous head position is reproducible, with maximum variations for AHPs of 2.88 degrees around the X-axis and 2.77 degrees around the Y-axis.

  2. Using a smartphone as a tool to measure compensatory and anomalous head positions

    Directory of Open Access Journals (Sweden)

    Michelle de Lima Farah

    Full Text Available ABSTRACT Purpose: To describe a new method for measuring anomalous head positions by using a cell phone. Methods: The photo rotation feature of the iPhone® PHOTOS application was used. With the patient seated on a chair, a horizontal stripe was fixed on the wall in the background and a sagittal stripe was fixed on the seat. Photographs were obtained in the following views: front view (photographs A and B; with the head tilted over one shoulder and upper axial view (photographs C and D; viewing the forehead and nose (A and C are without camera rotation, and B and D are with camera rotation. A blank sheet of paper with two straight lines making a 32-degree angle was also photographed. Thirty examiners were instructed to measure the rotation required to align the reference points with the orthogonal axes. In order to set benchmarks to be compared with the measurements obtained by the examiners, blue lines were digitally added to the front and upper view photographs. Results: In the photograph of the sheet of paper (p=0.380 and a=5%, the observed values did not differ statistically from the known value of 32 degrees. Mean measurements were as follows: front view photograph A, 22.8 ± 2.77; front view B, 21.4 ± 1.61; upper view C, 19.6 ± 2.36; and upper view D, 20.1 ± 2.33 degrees. The mean difference in measurements for the front view photograph A was -1.88 (95% CI -2.88 to -0.88, front view B was -0.37 (95% CI -0.97 to 0.17, upper view C was 1.43 (95% CI 0.55 to 2.24, and upper view D was 1.87 (95% CI 1.02 to 2.77. Conclusion: The method used in this study for measuring anomalous head position is reproducible, with maximum variations for AHPs of 2.88 degrees around the X-axis and 2.77 degrees around the Y-axis.

  3. Isocentric rotational performance of the Elekta Precise Table studied using a USB-microscope

    DEFF Research Database (Denmark)

    Riis, Hans L; Zimmermann, Sune J; Riis, Poul

    2010-01-01

    The isocentric three-dimensional performance of the Elekta Precise Table was investigated. A pointer was attached to the radiation head of the accelerator and positioned at the geometric rotational axis of the head. A USB-microscope was mounted on the treatment tabletop to measure the table...... position relative to the pointer tip. The table performance was mapped in terms of USB-microscope images of the pointer tip at different table angles and load configurations. The USB-microscope was used as a detector to measure the pointer tip positions with a resolution down to 0.01 mm. A new elastic...

  4. Do Puzzle Pieces and Autism Puzzle Piece Logos Evoke Negative Associations?

    Science.gov (United States)

    Gernsbacher, Morton Ann; Raimond, Adam R.; Stevenson, Jennifer L.; Boston, Jilana S.; Harp, Bev

    2018-01-01

    Puzzle pieces have become ubiquitous symbols for autism. However, puzzle-piece imagery stirs debate between those who support and those who object to its use because they believe puzzle-piece imagery evokes negative associations. Our study empirically investigated whether puzzle pieces evoke negative associations in the general public.…

  5. Self-Adaptive Correction of Heading Direction in Stair Climbing for Tracked Mobile Robots Using Visual Servoing Approach

    Science.gov (United States)

    Ji, Peng; Song, Aiguo; Song, Zimo; Liu, Yuqing; Jiang, Guohua; Zhao, Guopu

    2017-02-01

    In this paper, we describe a heading direction correction algorithm for a tracked mobile robot. To save hardware resources as far as possible, the mobile robot’s wrist camera is used as the only sensor, which is rotated to face stairs. An ensemble heading deviation detector is proposed to help the mobile robot correct its heading direction. To improve the generalization ability, a multi-scale Gabor filter is used to process the input image previously. Final deviation result is acquired by applying the majority vote strategy on all the classifiers’ results. The experimental results show that our detector is able to enable the mobile robot to correct its heading direction adaptively while it is climbing the stairs.

  6. Early components of the human vestibulo-ocular response to head rotation: latency and gain

    NARCIS (Netherlands)

    H. Collewijn (Han); J.B.J. Smeets (Jeroen)

    2000-01-01

    textabstractTo characterize vestibulo-ocular reflex (VOR) properties in the time window in which contributions by other systems are minimal, eye movements during the first 50-100 ms after the start of transient angular head accelerations ( approximately 1000 degrees

  7. An Eight-Week Clinical Evaluation of an Oscillating-Rotating Power Toothbrush with a Brush Head Utilizing Angled Bristles Compared with a Sonic Toothbrush in the Reduction of Gingivitis and Plaque.

    Science.gov (United States)

    Ccahuana-Vasquez, Renzo A; Conde, Erinn; Grender, Julie M; Cunningham, Pamela; Qaqish, Jimmy; Goyal, C Ram

    2015-01-01

    To evaluate and compare the efficacy of an oscillating-rotating (O-R) power toothbrush with a brush head utilizing angled bristles to a marketed sonic toothbrush in the reduction of plaque and gingivitis over an eight-week period. This study used a randomized, examiner-blind, single-center, two-treatment, parallel group, eight-week design. Subjects with mild-to-moderate plaque and gingivitis were evaluated for baseline whole mouth, gingival margin, and approximal plaque, gingivitis, and gingival bleeding. Clinical assessments were performed using the Modified Gingival Index, Gingival Bleeding Index, and the Rustogi Modified Navy Plaque Index. Subjects received either the O-R brush (Oral-B Professional Care 1000 [D16u] with Oral-B CrossAction brush head [EB50]) or the sonic brush (Sonicare DiamondClean with the standard DiamondClean brush head). Subjects brushed twice daily for two minutes per brushing with the assigned brush and a standard fluoride dentifrice for eight weeks before returning for plaque and gingivitis evaluations using the same methods. Prior to baseline and Week 8 measurements, participants abstained from oral hygiene for 12 hours. One hundred and forty-eight subjects completed the study; 75 in the O-R group and 73 in the sonic group. Both brushes demonstrated statistically significant reductions in plaque and gingivitis over the eight-week study period (p gingivitis than the sonic brush. Whole mouth, gingival margin, and approximal plaque reductions were 27.7%, 46.8%, and 29.3% greater, respectively, compared with the sonic brush, while the reductions in gingivitis, gingival bleeding, and number of bleeding sites were 34.6%, 36.4%, and 36.1% greater, respectively, for the O-R brush than for the sonic brush (p gingivitis reductions for the O-R power brush incorporating the angled-bristled brush head were significantly greater than for the sonic power brush.

  8. Numerical Investigation on a Prototype Centrifugal Pump Subjected to Fluctuating Rotational Speed

    Directory of Open Access Journals (Sweden)

    Yu-Liang Zhang

    2014-01-01

    Full Text Available The rotational speed of pumps often encounters fluctuation in engineering for some reasons. In this paper, in order to study the transient response characteristic of a prototype centrifugal pump subjected to fluctuating rotational speed, a closed-loop pipe system including the pump is built to accomplish unsteady flow calculations in which the boundary conditions at the inlet and the outlet of the pump are not required to be set. The external performance results show that the head’s responsiveness to the fluctuating rotational speed is very good, while the flow rate’s responsiveness is slightly delayed. The variation tendencies of the static pressures at the inlet and the outlet of the pump are almost completely opposite, wherein the variation tendency of the static pressure at the outlet is identical with that of the rotational speed. The intensity of the turbulence energy in each impeller channel is relatively uniform in the transient flow calculations, while, in the quasi-steady flow calculation, it becomes weaker in a channel closed to the volute tongue. The nondimensional flow rate and head coefficients are dependent on the rotational speed, and their variation tendencies are opposite to that of the fluctuating rotational speed as a whole.

  9. The evaluation of speed skating helmet performance through peak linear and rotational accelerations.

    Science.gov (United States)

    Karton, Clara; Rousseau, Philippe; Vassilyadi, Michael; Hoshizaki, Thomas Blaine

    2014-01-01

    Like many sports involving high speeds and body contact, head injuries are a concern for short track speed skating athletes and coaches. While the mandatory use of helmets has managed to nearly eliminate catastrophic head injuries such as skull fractures and cerebral haemorrhages, they may not be as effective at reducing the risk of a concussion. The purpose of this study was to evaluate the performance characteristics of speed skating helmets with respect to managing peak linear and peak rotational acceleration, and to compare their performance against other types of helmets commonly worn within the speed skating sport. Commercially available speed skating, bicycle and ice hockey helmets were evaluated using a three-impact condition test protocol at an impact velocity of 4 m/s. Two speed skating helmet models yielded mean peak linear accelerations at a low-estimated probability range for sustaining a concussion for all three impact conditions. Conversely, the resulting mean peak rotational acceleration values were all found close to the high end of a probability range for sustaining a concussion. A similar tendency was observed for the bicycle and ice hockey helmets under the same impact conditions. Speed skating helmets may not be as effective at managing rotational acceleration and therefore may not successfully protect the user against risks associated with concussion injuries.

  10. Refractory episodic vertigo: role of intratympanic gentamicin and vestibular evoked myogenic potentials,

    Directory of Open Access Journals (Sweden)

    Erika Celis-Aguilar

    Full Text Available Abstract Introduction: Even today, the treatment of intractable vertigo remains a challenge. Vestibular ablation with intratympanic gentamicin stands as a good alternative in the management of refractory vertigo patients. Objective: To control intractable vertigo through complete saccular and horizontal canal vestibular ablation with intratympanic gentamicin treatment. Methods: Patients with refractory episodic vertigo were included. The inclusion criteria were: unilateral ear disease, moderate to profound sensorineural hearing loss, and failure to other treatments. Included patients underwent 0.5-0.8 mL of gentamicin intratympanic application at a 30 mg/mL concentration. Vestibular ablation was confirmed by the absence of response on cervical vestibular evoked myogenic potentials and no response on caloric tests. Audiometry, electronystagmography with iced water, and vestibular evoked myogenic potentials were performed in all patients. Results: Ten patients were included; nine patients with Meniere's disease and one patient with (late onset delayed hydrops. Nine patients showed an absent response on vestibular evoked myogenic potentials and no response on caloric tests. The only patient with low amplitude on cervical vestibular evoked myogenic potentials had vertigo recurrence. Vertigo control was achieved in 90% of the patients. One patient developed hearing loss >30 dB. Conclusions: Cervical vestibular evoked myogenic potentials confirmed vestibular ablation in patients treated with intratympanic gentamicin. High-grade vertigo control was due to complete saccular and horizontal canal ablation (no response to iced water in electronystagmography and no response on cervical vestibular evoked myogenic potentials.

  11. Phantom somatosensory evoked potentials following selective intraneural electrical stimulation in two amputees.

    Science.gov (United States)

    Granata, Giuseppe; Di Iorio, Riccardo; Romanello, Roberto; Iodice, Francesco; Raspopovic, Stanisa; Petrini, Francesco; Strauss, Ivo; Valle, Giacomo; Stieglitz, Thomas; Čvančara, Paul; Andreu, David; Divoux, Jean-Louis; Guiraud, David; Wauters, Loic; Hiairrassary, Arthur; Jensen, Winnie; Micera, Silvestro; Rossini, Paolo Maria

    2018-06-01

    The aim of the paper is to objectively demonstrate that amputees implanted with intraneural interfaces are truly able to feel a sensation in the phantom hand by recording "phantom" somatosensory evoked potentials from the corresponding brain areas. We implanted four transverse intrafascicular multichannel electrodes, available with percutaneous connections to a multichannel electrical stimulator, in the median and ulnar nerves of two left trans-radial amputees. Two channels of the implants that were able to elicit sensations during intraneural nerve stimulation were chosen, in both patients, for recording somatosensory evoked potentials. We recorded reproducible evoked responses by stimulating the median and the ulnar nerves in both cases. Latencies were in accordance with the arrival of somatosensory information to the primary somatosensory cortex. Our results provide evidence that sensations generated by intraneural stimulation are truly perceived by amputees and located in the phantom hand. Moreover, our results strongly suggest that sensations perceived in different parts of the phantom hand result in different evoked responses. Somatosensory evoked potentials obtained by selective intraneural electrical stimulation in amputee patients are a useful tool to provide an objective demonstration of somatosensory feedback in new generation bidirectional prostheses. Copyright © 2018. Published by Elsevier B.V.

  12. Head-impact mechanisms in men's and women's collegiate ice hockey.

    Science.gov (United States)

    Wilcox, Bethany J; Machan, Jason T; Beckwith, Jonathan G; Greenwald, Richard M; Burmeister, Emily; Crisco, Joseph J

    2014-01-01

    Concussion injury rates in men's and women's ice hockey are reported to be among the highest of all collegiate sports. Quantification of the frequency of head impacts and the magnitude of head acceleration as a function of the different impact mechanisms (eg, head contact with the ice) that occur in ice hockey could provide a better understanding of this high injury rate. To quantify and compare the per-game frequency and magnitude of head impacts associated with various impact mechanisms in men's and women's collegiate ice hockey players. Cohort study. Collegiate ice hockey rink. Twenty-three men and 31 women from 2 National Collegiate Athletic Association Division I ice hockey teams. We analyzed magnitude and frequency (per game) of head impacts per player among impact mechanisms and between sexes using generalized mixed linear models and generalized estimating equations to account for repeated measures within players. Participants wore helmets instrumented with accelerometers to allow us to collect biomechanical measures of head impacts sustained during play. Video footage from 53 games was synchronized with the biomechanical data. Head impacts were classified into 8 categories: contact with another player; the ice, boards or glass, stick, puck, or goal; indirect contact; and contact from celebrating. For men and women, contact with another player was the most frequent impact mechanism, and contact with the ice generated the greatest-magnitude head accelerations. The men had higher per-game frequencies of head impacts from contact with another player and contact with the boards than did the women (P < .001), and these impacts were greater in peak rotational acceleration (P = .027). Identifying the impact mechanisms in collegiate ice hockey that result in frequent and high-magnitude head impacts will provide us with data that may improve our understanding of the high rate of concussion in the sport and inform injury-prevention strategies.

  13. The greater tuberosity angle: a new predictor for rotator cuff tear.

    Science.gov (United States)

    Cunningham, Gregory; Nicodème-Paulin, Emilie; Smith, Margaret M; Holzer, Nicolas; Cass, Benjamin; Young, Allan A

    2018-04-24

    The implication of scapular morphology in rotator cuff tears has been extensively studied. However, the role of the greater tuberosity (GT) should be of equal importance. The aim of this study was to propose a new radiographic marker, the GT angle (GTA), which measures the position of the GT in relation to the center of rotation of the humeral head. The hypothesis was that a higher angle value would be associated with a higher likelihood in detecting a rotator cuff tear. During 1 year, patients were prospectively recruited from a single institution specialized shoulder clinic in 2 different groups. The patient group consisted of individuals with a degenerative rotator cuff tear involving at least the supraspinatus. The control group consisted of individuals with no rotator cuff pathology. Individuals in both groups with congenital, post-traumatic, or degenerative alterations of the proximal humerus were excluded. The GTA was measured on an anteroposterior shoulder x-ray image with the arm in neutral rotation by 3 observers at 2 different times. The study recruited 71 patients (33 patients, 38 controls). Mean GTA value was 72.5° (range, 67.6°-79.2°) in patients and 65.2° (range, 55.8°-70.5°) for controls (P rotator cuff tear (P rotator cuff tears. The GTA is a reliable radiographic marker, with more than 70° being highly predictive in detecting such lesions. Copyright © 2018 Journal of Shoulder and Elbow Surgery Board of Trustees. All rights reserved.

  14. Galvanic vestibular stimulation combines with Earth-horizontal rotation in roll to induce the illusion of translation.

    Science.gov (United States)

    Schneider, Erich; Bartl, Klaus; Glasauer, Stefan

    2009-05-01

    Human head rotation in roll around an earth-horizontal axis constitutes a vestibular stimulus that, by its rotational component, acts on the semicircular canals (SCC) and that, by its tilt of the gravity vector, also acts on the otoliths. Galvanic vestibular stimulation (GVS) is thought to resemble mainly a rotation in roll. A superposition of sinusoidal GVS with a natural earth-horizontal roll movement was therefore applied in order to cancel the rotation effects and to isolate the otolith activation. By self-adjusting the amplitude and phase of GVS, subjects were able to minimize their sensation of rotation and to generate the perception of a linear translation. The final adjustments are in the range of a model that predicts SCC activation during natural rotations and GVS. This indicates that the tilt-translation ambiguity of the otoliths is resolved by SCC-otolith interaction. It is concluded that GVS might be able to cancel rotations in roll and that the residual tilt of the gravitoinertial force is possibly interpreted as a linear translation.

  15. An inventory and update of jealousy-evoking partner behaviours in modern society.

    Science.gov (United States)

    Dijkstra, Pieternel; Barelds, Dick P H; Groothof, Hinke A K

    2010-01-01

    The goal of the present study was to identify the most important jealousy-evoking partner behaviours and to examine the extent to which these behaviours evoke jealousy. Based on the literature, a questionnaire was constructed containing 42 jealousy-evoking partner behaviours, including a partner's extra-dyadic involvement with someone else by means of modern communication devices, such as the Internet. A second study examined the extent to which undergraduates and a community sample experienced jealousy in response to these partner behaviours. Results showed that explicit unfaithful behaviours evoked most feelings of jealousy, followed by a partner's emotional or romantic involvement with someone else by means of modern communication devices. In general, older individuals responded with less jealousy in response to a partner's unfaithful and suspicious behaviours. Clinical implications are discussed. (c) 2009 John Wiley & Sons, Ltd.

  16. Laminar boundary layer response to rotation of a finite diameter surface patch

    International Nuclear Information System (INIS)

    Klewicki, J.C.; Hill, R.B.

    2003-01-01

    The responses of the flat plate laminar boundary layer to perturbations generated by rotating a finite patch of the bounding surface are explored experimentally. The size of the surface patch was of the same order as the boundary layer thickness. The displacement thickness Reynolds number range of the boundary layers explored was 72-527. The rotation rates of the surface patch ranged from 2.14 to 62.8 s-1. Qualitative flow visualizations and quantitative molecular tagging velocimetry measurements revealed that rotation of a finite surface patch generates an asymmetric loop-like vortex. Significant features of this vortex include that, (i) the sign of the vorticity in the vortex head is opposite that of the boundary layer vorticity regardless of the sign of the input rotation, (ii) one leg of the vortex exhibits motion akin to solid body rotation while the other leg is best characterized as a spanwise shear layer, (iii) the vortex leg exhibiting near solid body rotation lifts more rapidly from the surface than the leg more like a shear layer, and (iv) the vortex leg exhibiting near solid body rotation always occurs on the side of the surface patch experiencing downstream motion. These asymmetries switch sides depending on the sign of the input rotation. The present results are interpreted and discussed relative to analytical solutions for infinite geometries. By way of analogy, plausible connections are drawn between the present results and the influences of wall normal vortices in turbulent boundary layer flows

  17. Evaluation of stereoscopic video cameras synchronized with the movement of an operator's head on the teleoperation of the actual backhoe shovel

    Science.gov (United States)

    Minamoto, Masahiko; Matsunaga, Katsuya

    1999-05-01

    Operator performance while using a remote controlled backhoe shovel is described for three different stereoscopic viewing conditions: direct view, fixed stereoscopic cameras connected to a helmet mounted display (HMD), and rotating stereo camera connected and slaved to the head orientation of a free moving stereo HMD. Results showed that the head- slaved system provided the best performance.

  18. Experiments of steady state head and torque of centrifugal pumps in two-phase flow

    International Nuclear Information System (INIS)

    Minato, Akihiko; Tominaga, Kenji.

    1988-01-01

    Circulation pump behavior has large effect on coolant discharge flow rate in case of reactor pipe break. Experiment of two-phase pump performance was conducted as a joint study of Japanese BWR user utilities and makers. Two-phase head and torque of three centrifugal pumps in high temperature and high pressure (around 6 MPa) steam/water were measured. Head was decreased from single-phase characteristics when gas was mixed in liquid flow in condition with normal flow and normal rotation directions. When flow rate was large enough, two-phase head was about the same as single-phase one in reversal flow conditions. Two-phase head was smoothly increased as flowing steam volumetic concentration increased when flow rate was small and flow direction was reversal. Changes of torque with gas concentration were correspondent to those of head. This suggested that changes of interaction between flow and impellers due to phase slip effected on torque which caused head differences between single- and two-phase flows. Dependence of dimensionless head and torque of three test pumps on steam concentration were almost the same as each other. (author)

  19. Evoked Brain Activity and Personnel Performance

    Science.gov (United States)

    1987-10-01

    Shucard and Horn (1972), Galbraith, Gliddon, and Busk (1970), and Callaway (1975), the latter using Navy recruits. Callaway’s own work was reported at...G.C., Gliddon, J.B., & Busk , J. (1970). Visual evoked responses in mentally retarded and nonretarded subjects. American Journal of Mental Deficiency

  20. Pathophysiological and behavioral deficits in developing mice following rotational acceleration-deceleration traumatic brain injury

    Directory of Open Access Journals (Sweden)

    Guoxiang Wang

    2018-01-01

    Full Text Available Abusive head trauma (AHT is the leading cause of death from trauma in infants and young children. An AHT animal model was developed on 12-day-old mice subjected to 90° head extension-flexion sagittal shaking repeated 30, 60, 80 and 100 times. The mortality and time until return of consciousness were dependent on the number of repeats and severity of the injury. Following 60 episodes of repeated head shakings, the pups demonstrated apnea and/or bradycardia immediately after injury. Acute oxygen desaturation was observed by pulse oximetry during respiratory and cardiac suppression. The cerebral blood perfusion was assessed by laser speckle contrast analysis (LASCA using a PeriCam PSI system. There was a severe reduction in cerebral blood perfusion immediately after the trauma that did not significantly improve within 24 h. The injured mice began to experience reversible sensorimotor function at 9 days postinjury (dpi, which had completely recovered at 28 dpi. However, cognitive deficits and anxiety-like behavior remained. Subdural/subarachnoid hemorrhage, damage to the brain-blood barrier and parenchymal edema were found in all pups subjected to 60 insults. Proinflammatory response and reactive gliosis were upregulated at 3 dpi. Degenerated neurons were found in the cerebral cortex and olfactory tubercles at 30 dpi. This mouse model of repetitive brain injury by rotational head acceleration-deceleration partially mimics the major pathophysiological and behavioral events that occur in children with AHT. The resultant hypoxia/ischemia suggests a potential mechanism underlying the secondary rotational acceleration-deceleration-induced brain injury in developing mice.

  1. Evoked potentials in pediatric cerebral malaria

    Directory of Open Access Journals (Sweden)

    Minal Bhanushali

    2011-12-01

    Full Text Available Cortical evoked potentials (EP provide localized data regarding brain function and may offer prognostic information and insights into the pathologic mechanisms of malariamediated cerebral injury. As part of a prospective cohort study, we obtained somatosensory evoked potentials (SSEPs and brainstem auditory EPs (AEPs within 24 hours of admission on 27 consecutive children admitted with cerebral malaria (CM. Children underwent follow-up for 12 months to determine if they had any long term neurologic sequelae. EPs were obtained in 27 pediatric CM admissions. Two children died. Among survivors followed an average of 514 days, 7/25 (28.0% had at least one adverse neurologic outcome. Only a single subject had absent cortical EPs on admission and this child had a good neurologic outcome. Among pediatric CM survivors, cortical EPs are generally intact and do not predict adverse neurologic outcomes. Further study is needed to determine if alterations in cortical EPs can be used to predict a fatal outcome in CM.

  2. Relative plan robustness of step-and-shoot vs rotational intensity–modulated radiotherapy on repeat computed tomographic simulation for weight loss in head and neck cancer

    International Nuclear Information System (INIS)

    Thomson, David J.; Beasley, William J.; Garcez, Kate; Lee, Lip W.; Sykes, Andrew J.; Rowbottom, Carl G.; Slevin, Nicholas J.

    2016-01-01

    Introduction: Interfractional anatomical alterations may have a differential effect on the dose delivered by step-and-shoot intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT). The increased degrees of freedom afforded by rotational delivery may increase plan robustness (measured by change in target volume coverage and doses to organs at risk [OARs]). However, this has not been evaluated for head and neck cancer. Materials and methods: A total of 10 patients who required repeat computed tomography (CT) simulation and replanning during head and neck IMRT were included. Step-and-shoot IMRT and VMAT plans were generated from the original planning scan. The initial and second CT simulation scans were fused and targets/OAR contours transferred, reviewed, and modified. The plans were applied to the second CT scan and doses recalculated without repeat optimization. Differences between step-and-shoot IMRT and VMAT for change in target volume coverage and doses to OARs between first and second CT scans were compared by Wilcoxon signed rank test. Results: There were clinically relevant dosimetric changes between the first and the second CT scans for both the techniques (reduction in mean D_9_5_% for PTV2 and PTV3, D_m_i_n for CTV2 and CTV3, and increased mean doses to the parotid glands). However, there were no significant differences between step-and-shoot IMRT and VMAT for change in any target coverage parameter (including D_9_5_% for PTV2 and PTV3 and D_m_i_n for CTV2 and CTV3) or dose to any OARs (including parotid glands) between the first and the second CT scans. Conclusions: For patients with head and neck cancer who required replanning mainly due to weight loss, there were no significant differences in plan robustness between step-and-shoot IMRT and VMAT. This information is useful with increased clinical adoption of VMAT.

  3. [Open double-row rotator cuff repair using the LASA-DR screw].

    Science.gov (United States)

    Schoch, C; Geyer, S; Geyer, M

    2016-02-01

    Safe and cost-effective rotator-cuff repair. All types of rotator cuff lesions. Frozen shoulder, rotator cuff mass defect, defect arthropathy. Extensive four-point fixation on the bony footprint is performed using the double-row lateral augmentation screw anchor (LASA-DR) with high biomechanical stability. Following mobilization of the tendons, these are refixed in the desired configuration first medially and then laterally. To this end, two drilling channels (footprint and lateral tubercle) are created for each screw. Using the shuttle technique, a suture anchor screw is reinforced with up to four pairs of threads. The medial row is then pierced and tied, and the sutures that have been left long are tied laterally around the screw heads (double row). 4 Weeks abduction pillow, resulting in passive physiotherapy, followed by initiation of active assisted physiotherapy. Full weight-bearing after 4-6 months. Prospective analysis of 35 consecutive Bateman-III lesions with excellent results and low rerupture rate (6%).

  4. Heading and head injuries in soccer.

    Science.gov (United States)

    Kirkendall, D T; Jordan, S E; Garrett, W E

    2001-01-01

    In the world of sports, soccer is unique because of the purposeful use of the unprotected head for controlling and advancing the ball. This skill obviously places the player at risk of head injury and the game does carry some risk. Head injury can be a result of contact of the head with another head (or other body parts), ground, goal post, other unknown objects or even the ball. Such impacts can lead to contusions, fractures, eye injuries, concussions or even, in rare cases, death. Coaches, players, parents and physicians are rightly concerned about the risk of head injury in soccer. Current research shows that selected soccer players have some degree of cognitive dysfunction. It is important to determine the reasons behind such deficits. Purposeful heading has been blamed, but a closer look at the studies that focus on heading has revealed methodological concerns that question the validity of blaming purposeful heading of the ball. The player's history and age (did they play when the ball was leather and could absorb significant amounts of water), alcohol intake, drug intake, learning disabilities, concussion definition and control group use/composition are all factors that cloud the ability to blame purposeful heading. What does seem clear is that a player's history of concussive episodes is a more likely explanation for cognitive deficits. While it is likely that the subconcussive impact of purposeful heading is a doubtful factor in the noted deficits, it is unknown whether multiple subconcussive impacts might have some lingering effects. In addition, it is unknown whether the noted deficits have any affect on daily life. Proper instruction in the technique is critical because if the ball contacts an unprepared head (as in accidental head-ball contacts), the potential for serious injury is possible. To further our understanding of the relationship of heading, head injury and cognitive deficits, we need to: learn more about the actual impact of a ball on the

  5. Laser-evoked coloration in polymers

    International Nuclear Information System (INIS)

    Zheng, H.Y.; Rosseinsky, David; Lim, G.C.

    2005-01-01

    Laser-evoked coloration in polymers has long been a major aim of polymer technology for potential applications in product surface decoration, marking personalised images and logos. However, the coloration results reported so far were mostly attributed to laser-induced thermal-chemical reactions. The laser-irradiated areas are characterized with grooves due to material removal. Furthermore, only single color was laser-induced in any given polymer matrix. To induce multiple colors in a given polymer matrix with no apparent surface material removal is most desirable and challenging and may be achieved through laser-induced photo-chemical reactions. However, little public information is available at present. We report that two colors of red and green have been produced on an initially transparent CPV/PVA samples through UV laser-induced photo-chemical reactions. This is believed the first observation of laser-induced multiple-colors in the given polymer matrix. It is believed that the colorants underwent photo-effected electron transfer with suitable electron donors from the polymers to change from colorless bipyridilium Bipm 2+ to the colored Bipm + species. The discovery may lead to new approaches to the development of laser-evoked multiple coloration in polymers

  6. Noninvasive scalp recording of cortical auditory evoked potentials in the alert macaque monkey.

    Science.gov (United States)

    Itoh, Kosuke; Nejime, Masafumi; Konoike, Naho; Nakada, Tsutomu; Nakamura, Katsuki

    2015-09-01

    Scalp-recorded evoked potentials (EP) provide researchers and clinicians with irreplaceable means for recording stimulus-related neural activities in the human brain, due to its high temporal resolution, handiness, and, perhaps more importantly, non-invasiveness. This work recorded the scalp cortical auditory EP (CAEP) in unanesthetized monkeys by using methods that are essentially identical to those applied to humans. Young adult rhesus monkeys (Macaca mulatta, 5-7 years old) were seated in a monkey chair, and their head movements were partially restricted by polystyrene blocks and tension poles placed around their head. Individual electrodes were fixated on their scalp using collodion according to the 10-20 system. Pure tone stimuli were presented while electroencephalograms were recorded from up to nineteen channels, including an electrooculogram channel. In all monkeys (n = 3), the recorded CAEP comprised a series of positive and negative deflections, labeled here as macaque P1 (mP1), macaque N1 (mN1), macaque P2 (mP2), and macaque N2 (mN2), and these transient responses to sound onset were followed by a sustained potential that continued for the duration of the sound, labeled the macaque sustained potential (mSP). mP1, mN2 and mSP were the prominent responses, and they had maximal amplitudes over frontal/central midline electrode sites, consistent with generators in auditory cortices. The study represents the first noninvasive scalp recording of CAEP in alert rhesus monkeys, to our knowledge. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Simultaneous recording of electroretinogram and visual evoked response. Focal stimulation under direct observation.

    Science.gov (United States)

    Hirose, T; Miyake, Y; Hara, A

    1977-07-01

    A system has been tested that allows simultaneous recording of the retinal response (electroretinogram [ERG]) and the occipital response (visual evoked response [VER]) with focal photic stimulation of the retina under direct observation of the fundus. A helium-neon gas laser is used as a stimulus source. The laser is chopped either by a pen motor or a rotating disc. The laser is attached to a biomicroscope through which the examiner can observe the fundus of the subject during the entire recording session. The optically clear contact lens is made with a flat surface that neutralizes refraction due to the cornea, thereby allowing fundus observation by microscope. Two metal wires mounted inside and outside of the lens serve as the electrode for the ERG. Graticules consisting of concentric circles and radial lines are projected onto the subject's fundus, providing a pattern that the examiner can use to determine the exact location to be stimulated in the fundus. With proper adjustment of stimulus and background illumination, local ERG and VER can be recorded simultaneously by stimulating the macula.

  8. Refractory episodic vertigo: role of intratympanic gentamicin and vestibular evoked myogenic potentials.

    Science.gov (United States)

    Celis-Aguilar, Erika; Hinojosa-González, Ramon; Vales-Hidalgo, Olivia; Coutinho-Toledo, Heloisa

    Even today, the treatment of intractable vertigo remains a challenge. Vestibular ablation with intratympanic gentamicin stands as a good alternative in the management of refractory vertigo patients. To control intractable vertigo through complete saccular and horizontal canal vestibular ablation with intratympanic gentamicin treatment. Patients with refractory episodic vertigo were included. The inclusion criteria were: unilateral ear disease, moderate to profound sensorineural hearing loss, and failure to other treatments. Included patients underwent 0.5-0.8mL of gentamicin intratympanic application at a 30mg/mL concentration. Vestibular ablation was confirmed by the absence of response on cervical vestibular evoked myogenic potentials and no response on caloric tests. Audiometry, electronystagmography with iced water, and vestibular evoked myogenic potentials were performed in all patients. Ten patients were included; nine patients with Meniere's disease and one patient with (late onset) delayed hydrops. Nine patients showed an absent response on vestibular evoked myogenic potentials and no response on caloric tests. The only patient with low amplitude on cervical vestibular evoked myogenic potentials had vertigo recurrence. Vertigo control was achieved in 90% of the patients. One patient developed hearing loss >30dB. Cervical vestibular evoked myogenic potentials confirmed vestibular ablation in patients treated with intratympanic gentamicin. High-grade vertigo control was due to complete saccular and horizontal canal ablation (no response to iced water in electronystagmography and no response on cervical vestibular evoked myogenic potentials). Copyright © 2016 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  9. A comparison of auditory evoked potentials to acoustic beats and to binaural beats.

    Science.gov (United States)

    Pratt, Hillel; Starr, Arnold; Michalewski, Henry J; Dimitrijevic, Andrew; Bleich, Naomi; Mittelman, Nomi

    2010-04-01

    The purpose of this study was to compare cortical brain responses evoked by amplitude modulated acoustic beats of 3 and 6 Hz in tones of 250 and 1000 Hz with those evoked by their binaural beats counterparts in unmodulated tones to indicate whether the cortical processes involved differ. Event-related potentials (ERPs) were recorded to 3- and 6-Hz acoustic and binaural beats in 2000 ms duration 250 and 1000 Hz tones presented with approximately 1 s intervals. Latency, amplitude and source current density estimates of ERP components to beats-evoked oscillations were determined and compared across beat types, beat frequencies and base (carrier) frequencies. All stimuli evoked tone-onset components followed by oscillations corresponding to the beat frequency, and a subsequent tone-offset complex. Beats-evoked oscillations were higher in amplitude in response to acoustic than to binaural beats, to 250 than to 1000 Hz base frequency and to 3 Hz than to 6 Hz beat frequency. Sources of the beats-evoked oscillations across all stimulus conditions located mostly to left temporal lobe areas. Differences between estimated sources of potentials to acoustic and binaural beats were not significant. The perceptions of binaural beats involve cortical activity that is not different than acoustic beats in distribution and in the effects of beat- and base frequency, indicating similar cortical processing. Copyright 2010 Elsevier B.V. All rights reserved.

  10. Study on change of multi-modally evoked potentials in nasopharyngeal carcinoma patients after radiotherapy

    International Nuclear Information System (INIS)

    Qin Ling; Chen Jiaxin; Zhang Lixiang; Wang Tiejian; Han Min; Lu Xiaoling

    2001-01-01

    Objective: To investigate possible changes of multi-modally evoked potentials in nasopharyngeal carcinoma patients after radiotherapy. Methods: Altogether 48 nasopharyngeal carcinoma patients receiving primary conventional external beam irradiation were examined before and after radiotherapy to determine their brainstem auditory-evoked potential (BAEP), short-latency somatosensory-evoked potential (SLSEP) and pattern reversal visual-evoked potential (PRVEP). Results: In comparison with the conditions before radiotherapy, in different periods after radiotherapy abnormal peak latency and interval latency difference were found in BAEP, SLSEP and PRVEP. Conclusion: Nasopharyngeal carcinoma after radiotherapy may cause abnormal function of nerve conduction in early periods, which can be showed by BAEP, SLSEP, PRVEP, and injury can be timely detected if the three evoked potentials are used together. Thus authors suggest BAEP, SLSEP, PRVEP should be examined in nasopharyngeal carcinoma patients during and after the radiotherapy so as to find early damage in auditory somatosensory and visual conduction pathways

  11. Sound localization with head movement: implications for 3-d audio displays.

    Directory of Open Access Journals (Sweden)

    Ken Ian McAnally

    2014-08-01

    Full Text Available Previous studies have shown that the accuracy of sound localization is improved if listeners are allowed to move their heads during signal presentation. This study describes the function relating localization accuracy to the extent of head movement in azimuth. Sounds that are difficult to localize were presented in the free field from sources at a wide range of azimuths and elevations. Sounds remained active until the participants’ heads had rotated through windows ranging in width of 2°, 4°, 8°, 16°, 32°, or 64° of azimuth. Error in determining sound-source elevation and the rate of front/back confusion were found to decrease with increases in azimuth window width. Error in determining sound-source lateral angle was not found to vary with azimuth window width. Implications for 3-d audio displays: The utility of a 3-d audio display for imparting spatial information is likely to be improved if operators are able to move their heads during signal presentation. Head movement may compensate in part for a paucity of spectral cues to sound-source location resulting from limitations in either the audio signals presented or the directional filters (i.e., head-related transfer functions used to generate a display. However, head movements of a moderate size (i.e., through around 32° of azimuth may be required to ensure that spatial information is conveyed with high accuracy.

  12. ARTHROSCOPIC CORRECTION OF THE INJURIES OF THE COMPLEX «TENDON OF THE BICEPS LONG HEAD - THE ARTICULAR LIP» IN TREATMENT OF PATIENTS WITH FULL-LAYER RUPTURES OF THE ROTATOR CUFF

    Directory of Open Access Journals (Sweden)

    S. Y. Dokolin

    2013-01-01

    Full Text Available Damage of the long head of the biceps at the place of attachment to the articular tubercle supraglenoidal lip of shoulder, to the entrance and throughout intertubercle furrows are common causes of pain and dysfunction of the shoulder joint. At the same clinical manifestations of the morphology of such lesions may be different. The current literature discusses various options of surgical correction of the biceps injury. Variety of methods of surgical treatment and the lack of consensus in support of their application in different patients in different types of injuries were the basis for the present study. A prospective analysis of the functional results of surgical treatment of the 34 - year’s patients with associated rotator cuff (SSP+ISP+SSC+ and the tendon of the biceps muscle in age from 34 to 75 years. Options for surgical correction of the damaged part of the biceps were: biceps tenotomy, biceps tenotomy with intraarticular tenodez of the shoulder to the head before entering intertubercle furrow, biceps tenotomy and extraarticular subpectorialtenodez to the proximal humerus is intertubercle interferrent screw groove, as well as its attachment to the tendon suture large pectoral muscle. Choice of surgical approach depended on the patient's age, level of daily physical activity, morphology and localization of lesions. The best results were obtained when the extra-articular subpectorialtenodez of long head of the biceps to the proximal humerus interferrent screw and suture fixation to the pectoralis major muscle, the average follow-up was 16,6 ± 4,7 months.

  13. Different strategies do not moderate primary motor cortex involvement in mental rotation: a TMS study

    Directory of Open Access Journals (Sweden)

    Koeneke Susan

    2007-08-01

    Full Text Available Abstract Background Regions of the dorsal visual stream are known to play an essential role during the process of mental rotation. The functional role of the primary motor cortex (M1 in mental rotation is however less clear. It has been suggested that the strategy used to mentally rotate objects determines M1 involvement. Based on the strategy hypothesis that distinguishes between an internal and an external strategy, our study was designed to specifically test the relation between strategy and M1 activity. Methods Twenty-two subjects were asked to participate in a standard mental rotation task. We used specific picture stimuli that were supposed to trigger either the internal (e.g. pictures of hands or tools or the external strategy (e.g. pictures of houses or abstract figures. The strategy hypothesis predicts an involvement of M1 only in case of stimuli triggering the internal strategy (imagine grasping and rotating the object by oneself. Single-pulse Transcranial Magnetic Stimulation (TMS was employed to quantify M1 activity during task performance by measuring Motor Evoked Potentials (MEPs at the right hand muscle. Results Contrary to the strategy hypothesis, we found no interaction between stimulus category and corticospinal excitability. Instead, corticospinal excitability was generally increased compared with a resting baseline although subjects indicated more frequent use of the external strategy for all object categories. Conclusion This finding suggests that M1 involvement is not exclusively linked with the use of the internal strategy but rather directly with the process of mental rotation. Alternatively, our results might support the hypothesis that M1 is active due to a 'spill-over' effect from adjacent brain regions.

  14. Different strategies do not moderate primary motor cortex involvement in mental rotation: a TMS study.

    Science.gov (United States)

    Bode, Stefan; Koeneke, Susan; Jäncke, Lutz

    2007-08-07

    Regions of the dorsal visual stream are known to play an essential role during the process of mental rotation. The functional role of the primary motor cortex (M1) in mental rotation is however less clear. It has been suggested that the strategy used to mentally rotate objects determines M1 involvement. Based on the strategy hypothesis that distinguishes between an internal and an external strategy, our study was designed to specifically test the relation between strategy and M1 activity. Twenty-two subjects were asked to participate in a standard mental rotation task. We used specific picture stimuli that were supposed to trigger either the internal (e.g. pictures of hands or tools) or the external strategy (e.g. pictures of houses or abstract figures). The strategy hypothesis predicts an involvement of M1 only in case of stimuli triggering the internal strategy (imagine grasping and rotating the object by oneself). Single-pulse Transcranial Magnetic Stimulation (TMS) was employed to quantify M1 activity during task performance by measuring Motor Evoked Potentials (MEPs) at the right hand muscle. Contrary to the strategy hypothesis, we found no interaction between stimulus category and corticospinal excitability. Instead, corticospinal excitability was generally increased compared with a resting baseline although subjects indicated more frequent use of the external strategy for all object categories. This finding suggests that M1 involvement is not exclusively linked with the use of the internal strategy but rather directly with the process of mental rotation. Alternatively, our results might support the hypothesis that M1 is active due to a 'spill-over' effect from adjacent brain regions.

  15. Transcranial motor evoked potential waveform changes in corrective fusion for adolescent idiopathic scoliosis.

    Science.gov (United States)

    Kobayashi, Kazuyoshi; Imagama, Shiro; Ito, Zenya; Ando, Kei; Hida, Tetsuro; Ito, Kenyu; Tsushima, Mikito; Ishikawa, Yoshimoto; Matsumoto, Akiyuki; Nishida, Yoshihiro; Ishiguro, Naoki

    2017-01-01

    OBJECTIVE Corrective surgery for spinal deformities can lead to neurological complications. Several reports have described spinal cord monitoring in surgery for spinal deformity, but only a few have included patients younger than 20 years with adolescent idiopathic scoliosis (AIS). The goal of this study was to evaluate the characteristics of cases with intraoperative transcranial motor evoked potential (Tc-MEP) waveform deterioration during posterior corrective fusion for AIS. METHODS A prospective database was reviewed, comprising 68 patients with AIS who were treated with posterior corrective fusion in a prospective database. A total of 864 muscles in the lower extremities were chosen for monitoring, and acceptable baseline responses were obtained from 819 muscles (95%). Intraoperative Tc-MEP waveform deterioration was defined as a decrease in intraoperative amplitude of ≥ 70% of the control waveform. Age, Cobb angle, flexibility, operative time, estimated blood loss (EBL), intraoperative body temperature, blood pressure, number of levels fused, and correction rate were examined in patients with and without waveform deterioration. RESULTS The patients (3 males and 65 females) had an average age of 14.4 years (range 11-19 years). The mean Cobb angles before and after surgery were 52.9° and 11.9°, respectively, giving a correction rate of 77.4%. Fourteen patients (20%) exhibited an intraoperative waveform change, and these occurred during incision (14%), after screw fixation (7%), during the rotation maneuver (64%), during placement of the second rod after the rotation maneuver (7%), and after intervertebral compression (7%). Most waveform changes recovered after decreased correction or rest. No patient had a motor deficit postoperatively. In multivariate analysis, EBL (OR 1.001, p = 0.085) and number of levels fused (OR 1.535, p = 0.045) were associated with waveform deterioration. CONCLUSIONS Waveform deterioration commonly occurred during rotation maneuvers

  16. Index finger somatosensory evoked potentials in blind Braille readers.

    Science.gov (United States)

    Giriyappa, Dayananda; Subrahmanyam, Roopakala Mysore; Rangashetty, Srinivasa; Sharma, Rajeev

    2009-01-01

    Traditionally, vision has been considered the dominant modality in our multi-sensory perception of the surrounding world. Sensory input via non-visual tracts becomes of greater behavioural relevance in totally blind individuals to enable effective interaction with the world around them. These include audition and tactile perceptions, leading to an augmentation in these perceptions when compared with normal sighted individuals. The objective of the present work was to study the index finger somatosensory evoked potentials (SEPs) in totally blind and normal sighted individuals. SEPs were recorded in 15 Braille reading totally blind females and compared with 15 age-matched normal sighted females. Latency and amplitudes of somatosensory evoked potential waveforms (N9, N13, and N20) were measured. Amplitude of N20 SEP (a cortical somatosensory evoked potential) was significantly larger in the totally blind than in normal sighted individuals (p Braille reading right index finger. Totally blind Braille readers have larger N20 amplitude, suggestive of greater somatosensory cortical representation of the Braille reading index finger.

  17. Early visual evoked potentials are modulated by eye position in humans induced by whole body rotations

    Directory of Open Access Journals (Sweden)

    Petit Laurent

    2004-09-01

    Full Text Available Abstract Background To reach and grasp an object in space on the basis of its image cast on the retina requires different coordinate transformations that take into account gaze and limb positioning. Eye position in the orbit influences the image's conversion from retinotopic (eye-centered coordinates to an egocentric frame necessary for guiding action. Neuroimaging studies have revealed eye position-dependent activity in extrastriate visual, parietal and frontal areas that is along the visuo-motor pathway. At the earliest vision stage, the role of the primary visual area (V1 in this process remains unclear. We used an experimental design based on pattern-onset visual evoked potentials (VEP recordings to study the effect of eye position on V1 activity in humans. Results We showed that the amplitude of the initial C1 component of VEP, acknowledged to originate in V1, was modulated by the eye position. We also established that putative spontaneous small saccades related to eccentric fixation, as well as retinal disparity cannot explain the effects of changing C1 amplitude of VEP in the present study. Conclusions The present modulation of the early component of VEP suggests an eye position-dependent activity of the human primary visual area. Our findings also evidence that cortical processes combine information about the position of the stimulus on the retinae with information about the location of the eyes in their orbit as early as the stage of primary visual area.

  18. Newborn hearing screening with transient evoked otoacoustic emissions and automatic auditory brainstem response

    Directory of Open Access Journals (Sweden)

    Renata Mota Mamede de Carvallo

    2008-09-01

    Full Text Available Objective: The aim of the present investigation was to check Transient Evoked Otoacoustic Emissions and Automatic Auditory Brainstem Response tests applied together in regular nurseries and Newborn Intensive Care Units (NICU, as well as to describe and compare the results obtained in both groups. Methods: We tested 150 newborns from regular nurseries and 70 from NICU. Rresults: The newborn hearing screening results using Transient Evoked Otoacoustic Emissions and Automatic Auditory Brainstem Response tests could be applied to all babies. The “pass” result for the group of babies from the nursery was 94.7% using Transient Evoked Otoacoustic Emissions and 96% using Automatic Auditory Brainstem Response. The newborn intensive care unit group obtained 87.1% on Transient Evoked Otoacoustic Emissions and 80% on the Automatic Auditory Brainstem Response, and there was no statistical difference between the procedures when the groups were evaluated individually. However, comparing the groups, Transient Evoked Otoacoustic Emissions were presented in 94.7% of the nursery babies and in 87.1% in the group from the newborn intensive care unit. Considering the Automatic Auditory Brainstem Response, we found 96 and 87%, respectively. Cconclusions: Transient Evoked Otoacoustic Emissions and Automatic Auditory Brainstem Response had similar “pass” and “fail” results when the procedures were applied to neonates from the regular nursery, and the combined tests were more precise to detect hearing impairment in the newborn intensive care unit babies.

  19. Sex differences in the jealousy-evoking nature of a rival's body build

    NARCIS (Netherlands)

    Dijkstra, Pieternel; Buunk, Abraham (Bram)

    This study among 185 college students showed that potential rivals with a relatively low waist-to-hip ratio (WHR) evoked more jealousy in women than in men. In contrast, rivals with a relatively high shoulder-to-hip ratio (SHR) evoked more jealousy in men than in women, particularly when the rival

  20. Enhanced brainstem and cortical evoked response amplitudes: single-trial covariance analysis.

    Science.gov (United States)

    Galbraith, G C

    2001-06-01

    The purpose of the present study was to develop analytic procedures that improve the definition of sensory evoked response components. Such procedures could benefit all recordings but would especially benefit difficult recordings where many trials are contaminated by muscle and movement artifacts. First, cross-correlation and latency adjustment analyses were applied to the human brainstem frequency-following response and cortical auditory evoked response recorded on the same trials. Lagged cross-correlation functions were computed, for each of 17 subjects, between single-trial data and templates consisting of the sinusoid stimulus waveform for the brainstem response and the subject's own smoothed averaged evoked response P2 component for the cortical response. Trials were considered in the analysis only if the maximum correlation-squared (r2) exceeded .5 (negatively correlated trials were thus included). Identical correlation coefficients may be based on signals with quite different amplitudes, but it is possible to assess amplitude by the nonnormalized covariance function. Next, an algorithm is applied in which each trial with negative covariance is matched to a trial with similar, but positive, covariance and these matched-trial pairs are deleted. When an evoked response signal is present in the data, the majority of trials positively correlate with the template. Thus, a residual of positively correlated trials remains after matched covariance trials are deleted. When these residual trials are averaged, the resulting brainstem and cortical responses show greatly enhanced amplitudes. This result supports the utility of this analysis technique in clarifying and assessing evoked response signals.

  1. Is Urgent Evoke a Digital Ba?

    DEFF Research Database (Denmark)

    Wichmand, Mette

    2018-01-01

    of such a platform, the World Bank’s online game Urgent Evoke, which has been designed with the pur- pose of engaging citizens in developing innovative solutions for sociopolitical problems like poverty. The analysis is based on Nonaka’s concept of Ba, which means “place” and is described as a platform for advancing...

  2. Potencial evocado miogênico vestibular: novas perspectivas diagnósticas em esclerose múltipla Vestibular evoked myogenic potential: new perspectives in multiple sclerosis

    Directory of Open Access Journals (Sweden)

    Renata Chade Aidar

    2005-02-01

    (n=15 that comprised patients with diagnosis of multiple sclerosis. Both groups were submitted to vestibular evoked myogenic potential exam. In each ear it was applied 200 stimuli by clicks and repeated for 2 consecutive cycles with the purpose of evaluating reproducibility. The active electrode of surface was put on the superior S‡of sternocleidomastoid muscle and the reference electrode on the anterior border of the clavicle. The individuals were instructed to rotate theirs head to the opposite side to the stimulated ear. RESULTS: Vestibular evoked myogenic potential responses were prompt, reproducible and biphasic. The latency of wave P1 and N2 and P1-N2 amplitude showed a higher value in the studied group when compared with the normal group. There was no significant difference when the ears were compared in P1 and N2 amplitude. We noticed that individuals with multiple sclerosis showed no response in 30% of the cases. In evaluating the individuals of the Studied group with otoneurology symptoms and compared with individuals without symptoms, it was observed that P1 and N2 latencies and P1-N2 amplitude were higher in symptomatic cases. CONCLUSION: Vestibular evoked myogenic potential was considered a good method of diagnostic support of vestibulospinal tract in cases of multiple sclerosis.

  3. An innovative design of small low head hydropower units for low cost decentralized production

    International Nuclear Information System (INIS)

    Holmen, E.; Dennehy, T.

    1991-01-01

    Design allowing turbine operation at heads as low as 1m and operating at a rotational speed of 500 RPM at a flow of 2.6m 3 /s and a runner diameter of 700 mm. This eliminates the need for a gear box and helps in achieving efficiency of 60% in the case of a 21 kW installation at a 1m head site and 85% with a 69 kW 3.2m head site. Present turbine designs for such low head sites are very expensive to produce and have a low efficiency. The design uses an all plastic waterway, guide vane assembly and reinforced plastic runner blades. There will be a short pay-back period, for example 4.5 years in the case of a 21 kW unit and 2.0 years in case of the 69 kW unit. These payback periods assume a cost per kW of 0.00 ECU. Design is attractive for decentralized production. 3 figs

  4. Multiple regions-of-interest analysis of setup uncertainties for head-and-neck cancer radiotherapy

    International Nuclear Information System (INIS)

    Zhang Lifei; Garden, Adam S.; Lo, Justin; Ang, K. Kian; Ahamad, Anesa; Morrison, William H.; Rosenthal, David I.; Chambers, Mark S.; Zhu, X. Ronald; Mohan, Radhe; Dong Lei

    2006-01-01

    Purpose: To analyze three-dimensional setup uncertainties for multiple regions of interest (ROIs) in head-and-neck region. Methods and Materials: In-room computed tomography (CT) scans were acquired using a CT-on-rails system for 14 patients. Three separate bony ROIs were defined: C2 and C6 vertebral bodies and the palatine process of the maxilla. Translational shifts of 3 ROIs were calculated relative to the marked isocenter on the immobilization mask. Results: The shifts for all 3 ROIs were highly correlated. However, noticeable differences on the order of 2-6 mm existed between any 2 ROIs, indicating the flexibility and/or rotational effect in the head-and-neck region. The palatine process of the maxilla had the smallest right-left shifts because of the tight lateral fit in the face mask, but the largest superior-inferior movement because of in-plane rotation and variations in jaw positions. The neck region (C6) had the largest right-left shifts. The positioning mouthpiece was found effective in reducing variations in the superior-inferior direction. There was no statistically significant improvement for using the S-board (8 out of 14 patients) vs. the short face mask. Conclusions: We found variability in setup corrections for different regions of head-and-neck anatomy. These relative positional variations should be considered when making setup corrections or designing treatment margins

  5. The impact of several craniotomies on transcranial motor evoked potential monitoring during neurosurgery.

    Science.gov (United States)

    Tomio, Ryosuke; Akiyama, Takenori; Toda, Masahiro; Ohira, Takayuki; Yoshida, Kazunari

    2017-09-01

    OBJECTIVE Transcranial motor evoked potential (tMEP) monitoring is popular in neurosurgery; however, the accuracy of tMEP can be impaired by craniotomy. Each craniotomy procedure and changes in the CSF levels affects the current spread. The aim of this study was to investigate the influence of several craniotomies on tMEP monitoring by using C3-4 transcranial electrical stimulation (TES). METHODS The authors used the finite element method to visualize the electric field in the brain, which was generated by TES, using realistic 3D head models developed from T1-weighted MR images. Surfaces of 5 layers of the head (brain, CSF, skull, subcutaneous fat, and skin layer) were separated as accurately as possible. The authors created 5 models of the head, as follows: normal head; frontotemporal craniotomy; parietal craniotomy; temporal craniotomy; and occipital craniotomy. The computer simulation was investigated by finite element methods, and clinical recordings of the stimulation threshold level of upper-extremity tMEP (UE-tMEP) during neurosurgery were also studied in 30 patients to validate the simulation study. RESULTS Bone removal during the craniotomy positively affected the generation of the electric field in the motor cortex if the motor cortex was just under the bone at the margin of the craniotomy window. This finding from the authors' simulation study was consistent with clinical reports of frontotemporal craniotomy cases. A major decrease in CSF levels during an operation had a significantly negative impact on the electric field when the motor cortex was exposed to air. The CSF surface level during neurosurgery depends on the body position and location of the craniotomy. The parietal craniotomy and temporal craniotomy were susceptible to the effect of the changing CSF level, based on the simulation study. A marked increase in the threshold following a decrease in CSF was actually recorded in clinical reports of the UE-tMEP threshold from a temporal craniotomy

  6. Rotator cuff tendon connections with the rotator cable.

    Science.gov (United States)

    Rahu, Madis; Kolts, Ivo; Põldoja, Elle; Kask, Kristo

    2017-07-01

    The literature currently contains no descriptions of the rotator cuff tendons, which also describes in relation to the presence and characteristics of the rotator cable (anatomically known as the ligamentum semicirculare humeri). The aim of the current study was to elucidate the detailed anatomy of the rotator cuff tendons in association with the rotator cable. Anatomic dissection was performed on 21 fresh-frozen shoulder specimens with an average age of 68 years. The rotator cuff tendons were dissected from each other and from the glenohumeral joint capsule, and the superior glenohumeral, coracohumeral, coracoglenoidal and semicircular (rotator cable) ligaments were dissected. Dissection was performed layer by layer and from the bursal side to the joint. All ligaments and tendons were dissected in fine detail. The rotator cable was found in all specimens. It was tightly connected to the supraspinatus (SSP) tendon, which was partly covered by the infraspinatus (ISP) tendon. The posterior insertion area of the rotator cable was located in the region between the middle and inferior facets of the greater tubercle of the humerus insertion areas for the teres minor (TM), and ISP tendons were also present and fibres from the SSP extended through the rotator cable to those areas. The connection between the rotator cable and rotator cuff tendons is tight and confirms the suspension bridge theory for rotator cuff tears in most areas between the SSP tendons and rotator cable. In its posterior insertion area, the rotator cable is a connecting structure between the TM, ISP and SSP tendons. These findings might explain why some patients with relatively large rotator cuff tears can maintain seamless shoulder function.

  7. Hydrocoil Turbine Performance at 3 m, 4 m, and 5 m Head Analysis Using Computational Fluid Dynamics Method

    Science.gov (United States)

    Luthfie, A. A.; Pratiwi, S. E.; Hidayatulloh, P.

    2018-03-01

    Indonesia is a country which has abundant renewable energy resources, comprises of water, solar, geothermal, wind, bioenergy, and ocean energy. Utilization of water energy through MHP is widely applied in remote areas in Indonesia. This utilization requires a water-converting device known as a water turbine. Rosefsky (2010) developed a water turbine known as the Hydrocoil turbine. This turbine is an axial turbine which is a modification of screw turbine. This turbine has a pitch length that decreases in the direction of the water flow and is able to work at relatively low water flow and head. The use of Hydrocoil turbine has not been widely applied in Indonesia, therefore this research is focused on analyzing the performance of Hydrocoil turbine. The analysis was performed using Computational Fluid Dynamics (CFD) method. Hydrocoil turbine performance analysis was performed at 3 m, 4 m, and 5 m head respectively as well as rotational speed variations of 100 rpm, 300 rpm, 500 rpm, 700 rpm, 900 rpm, 1,100 rpm, 1,300 rpm, 1,500 rpm, 1,700 rpm, and 1,900 rpm. Based on simulation result, the largest power generated by the turbine at 3 m head is 1,134.06 W, while at 4 m and 5 m are 1,722.39 W and 2,231.49 W respectively. It is also found that the largest turbine’s efficiency at 3 m head is 93.22% while at 4 m and 5 m head are 94.6% and 89.88% respectively. The result also shows that the larger the head the greater the operational rotational speed range.

  8. Evoked Emotions Predict Food Choice

    OpenAIRE

    Dalenberg, Jelle R.; Gutjar, Swetlana; ter Horst, Gert J.; de Graaf, Kees; Renken, Remco J.; Jager, Gerry

    2014-01-01

    In the current study we show that non-verbal food-evoked emotion scores significantly improve food choice prediction over merely liking scores. Previous research has shown that liking measures correlate with choice. However, liking is no strong predictor for food choice in real life environments. Therefore, the focus within recent studies shifted towards using emotion-profiling methods that successfully can discriminate between products that are equally liked. However, it is unclear how well ...

  9. SU-F-I-46: Optimizing Dose Reduction in Adult Head CT Protocols While Maintaining Image Quality in Postmortem Head Scans

    International Nuclear Information System (INIS)

    Lipnharski, I; Carranza, C; Quails, N; Correa, N; Rajderkar, D; Bennett, J; Rill, L; Arreola, M

    2016-01-01

    Purpose: To optimize adult head CT protocol by reducing dose to an appropriate level while providing CT images of diagnostic quality. Methods: Five cadavers were scanned from the skull base to the vertex using a routine adult head CT protocol (120 kVp, 270 mA, 0.75 s rotation, 0.5 mm × 32 detectors, 70.8 mGy CTDIvol) followed by seven reduced-dose protocols with varying combinations of reduced tube current, reduced rotation time, and increased detectors with CTDIvol ranging from 38.2 to 65.6 mGy. Organ doses were directly measured with 21 OSL dosimeters placed on the surface and implanted in the head by a neurosurgeon. Two neuroradiologists assessed grey-white matter differentiation, fluid space, ventricular size, midline shift, brain mass, edema, ischemia, and skull fractures on a three point scale: (1) Unacceptable, (2) Borderline Acceptable, and (3) Acceptable. Results: For the standard scan, doses to the skin, lens of the eye, salivary glands, thyroid, and brain were 37.55 mGy, 49.65 mGy, 40.67 mGy, 4.63 mGy, and 27.33 mGy, respectively. Two cadavers had cerebral edema due to changing dynamics of postmortem effects, causing the grey-white matter differentiation to appear less distinct. Two cadavers with preserved grey-white matter received acceptable scores for all image quality features for the protocol with a CTDIvol of 57.3 mGy, allowing organ dose savings ranging from 34% to 45%. One cadaver allowed for greater dose reduction for the protocol with a CTDIvol of 42 mGy. Conclusion: Efforts to optimize scan protocol should consider both dose and clinical image quality. This is made possible with postmortem subjects, whose brains are similar to patients, allowing for an investigation of ideal scan parameters. Radiologists at our institution accepted scan protocols acquired with lower scan parameters, with CTDIvol values closer to the American College of Radiology’s (ACR) Achievable Dose level of 57 mGy.

  10. SU-F-I-46: Optimizing Dose Reduction in Adult Head CT Protocols While Maintaining Image Quality in Postmortem Head Scans

    Energy Technology Data Exchange (ETDEWEB)

    Lipnharski, I; Carranza, C; Quails, N; Correa, N; Rajderkar, D; Bennett, J; Rill, L; Arreola, M [University of Florida, Gainesville, FL (United States)

    2016-06-15

    Purpose: To optimize adult head CT protocol by reducing dose to an appropriate level while providing CT images of diagnostic quality. Methods: Five cadavers were scanned from the skull base to the vertex using a routine adult head CT protocol (120 kVp, 270 mA, 0.75 s rotation, 0.5 mm × 32 detectors, 70.8 mGy CTDIvol) followed by seven reduced-dose protocols with varying combinations of reduced tube current, reduced rotation time, and increased detectors with CTDIvol ranging from 38.2 to 65.6 mGy. Organ doses were directly measured with 21 OSL dosimeters placed on the surface and implanted in the head by a neurosurgeon. Two neuroradiologists assessed grey-white matter differentiation, fluid space, ventricular size, midline shift, brain mass, edema, ischemia, and skull fractures on a three point scale: (1) Unacceptable, (2) Borderline Acceptable, and (3) Acceptable. Results: For the standard scan, doses to the skin, lens of the eye, salivary glands, thyroid, and brain were 37.55 mGy, 49.65 mGy, 40.67 mGy, 4.63 mGy, and 27.33 mGy, respectively. Two cadavers had cerebral edema due to changing dynamics of postmortem effects, causing the grey-white matter differentiation to appear less distinct. Two cadavers with preserved grey-white matter received acceptable scores for all image quality features for the protocol with a CTDIvol of 57.3 mGy, allowing organ dose savings ranging from 34% to 45%. One cadaver allowed for greater dose reduction for the protocol with a CTDIvol of 42 mGy. Conclusion: Efforts to optimize scan protocol should consider both dose and clinical image quality. This is made possible with postmortem subjects, whose brains are similar to patients, allowing for an investigation of ideal scan parameters. Radiologists at our institution accepted scan protocols acquired with lower scan parameters, with CTDIvol values closer to the American College of Radiology’s (ACR) Achievable Dose level of 57 mGy.

  11. Unsteady flow simulations of Pelton turbine at different rotational speeds

    Directory of Open Access Journals (Sweden)

    Minsuk Choi

    2015-11-01

    Full Text Available This article presents numerical simulations of a small Pelton turbine suitable for desalination system. A commercial flow solver was adopted to resolve difficulties in the numerical simulation for Pelton turbine such as the relative motion of the turbine runner to the injector and two-phase flow of water and air. To decrease the numerical diffusion of the water jet, a new topology with only hexagonal mesh was suggested for the computational mesh around the complex geometry of a bucket. The predicted flow coefficient, net head coefficient, and overall efficiency showed a good agreement with the experimental data. Based on the validation of the numerical results, the pattern of wet area on the bucket inner surface has been analyzed at different rotational speeds, and an attempt to find the connection between rotational speeds, torque, and efficiency has been made.

  12. Improved Imaging of Magnetically Labeled Cells Using Rotational Magnetomotive Optical Coherence Tomography

    Directory of Open Access Journals (Sweden)

    Peter Cimalla

    2017-04-01

    Full Text Available In this paper, we present a reliable and robust method for magnetomotive optical coherence tomography (MM-OCT imaging of single cells labeled with iron oxide particles. This method employs modulated longitudinal and transverse magnetic fields to evoke alignment and rotation of anisotropic magnetic structures in the sample volume. Experimental evidence suggests that magnetic particles assemble themselves in elongated chains when exposed to a permanent magnetic field. Magnetomotion in the intracellular space was detected and visualized by means of 3D OCT as well as laser speckle reflectometry as a 2D reference imaging method. Our experiments on mesenchymal stem cells embedded in agar scaffolds show that the magnetomotive signal in rotational MM-OCT is significantly increased by a factor of ~3 compared to previous pulsed MM-OCT, although the solenoid’s power consumption was 16 times lower. Finally, we use our novel method to image ARPE-19 cells, a human retinal pigment epithelium cell line. Our results permit magnetomotive imaging with higher sensitivity and the use of low power magnetic fields or larger working distances for future three-dimensional cell tracking in target tissues and organs.

  13. Effect of peripherally and cortically evoked swallows on jaw reflex responses in anesthetized rabbits.

    Science.gov (United States)

    Suzuki, Taku; Yoshihara, Midori; Sakai, Shogo; Tsuji, Kojun; Nagoya, Kouta; Magara, Jin; Tsujimura, Takanori; Inoue, Makoto

    2018-05-03

    This study aimed to investigate whether the jaw-opening (JOR) and jaw-closing reflexes (JCR) are modulated during not only peripherally, but also centrally, evoked swallowing. Experiments were carried out on 24 adult male Japanese white rabbits. JORs were evoked by trigeminal stimulation at 1 Hz for 30 sec. In the middle 10 sec, either the superior laryngeal nerve (SLN) or cortical swallowing area (Cx) was simultaneously stimulated to evoke swallowing. The peak-to-peak JOR amplitude was reduced during the middle and late 10-sec periods (i.e., during and after SLN or Cx stimulation), and the reduction was dependent on the current intensity of SLN/Cx stimulation: greater SLN/Cx stimulus current resulted in greater JOR inhibition. The reduction rate was significantly greater during Cx stimulation than during SLN stimulation. The amplitude returned to baseline 2 min after 10-sec SLN/Cx stimulation. The effect of co-stimulation of SLN and Cx was significantly greater than that of SLN stimulation alone. There were no significant differences in any parameters of the JCR between conditions. These results clearly showed that JOR responses were significantly suppressed, not only during peripherally evoked swallowing but also during centrally evoked swallowing, and that the inhibitory effect is likely to be larger during centrally compared with peripherally evoked swallowing. The functional implications of these results are discussed. Copyright © 2018. Published by Elsevier B.V.

  14. On the vertigo due to static magnetic fields.

    Science.gov (United States)

    Mian, Omar S; Li, Yan; Antunes, Andre; Glover, Paul M; Day, Brian L

    2013-01-01

    Vertigo is sometimes experienced in and around MRI scanners. Mechanisms involving stimulation of the vestibular system by movement in magnetic fields or magnetic field spatial gradients have been proposed. However, it was recently shown that vestibular-dependent ocular nystagmus is evoked when stationary in homogenous static magnetic fields. The proposed mechanism involves Lorentz forces acting on endolymph to deflect semicircular canal (SCC) cupulae. To investigate whether vertigo arises from a similar mechanism we recorded qualitative and quantitative aspects of vertigo and 2D eye movements from supine healthy adults (n = 25) deprived of vision while pushed into the 7T static field of an MRI scanner. Exposures were variable and included up to 135s stationary at 7T. Nystagmus was mainly horizontal, persisted during long-exposures with partial decline, and reversed upon withdrawal. The dominant vertiginous perception with the head facing up was rotation in the horizontal plane (85% incidence) with a consistent direction across participants. With the head turned 90 degrees in yaw the perception did not transform into equivalent vertical plane rotation, indicating a context-dependency of the perception. During long exposures, illusory rotation lasted on average 50 s, including 42 s whilst stationary at 7T. Upon withdrawal, perception re-emerged and reversed, lasting on average 30 s. Onset fields for nystagmus and perception were significantly correlated (p<.05). Although perception did not persist as long as nystagmus, this is a known feature of continuous SSC stimulation. These observations, and others in the paper, are compatible with magnetic-field evoked-vertigo and nystagmus sharing a common mechanism. With this interpretation, response decay and reversal upon withdrawal from the field, are due to adaptation to continuous vestibular input. Although the study does not entirely exclude the possibility of mechanisms involving transient vestibular stimulation

  15. Diagnostic accuracy of 3T conventional shoulder MRI in the detection of the long head of the biceps tendon tears associated with rotator cuff tendon tears

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ro Woon; Choi, Soo-Jung; Ahn, Jae Hong; Shin, Dong Rock; Kang, Chae Hoon [University of Ulsan, College of Medicine, Department of Radiology, Asan Foundation, Gangneung Asan Hospital, Gangneung-si, Gangwon-do (Korea, Republic of); Lee, Man Ho [Andong Medical Center, Department of Radiology, Andong-si, Gyeongsangbuk-do (Korea, Republic of); Lee, Ki Won [University of Ulsan, College of Medicine, Department of Orthopedic Surgery, Asan Foundation, Gangneung Asan Hospital, Gangneung-si, Gangwon-do (Korea, Republic of)

    2016-12-15

    To evaluate the diagnostic performance (DP) of 3T (3 Tesla field strength) conventional shoulder magnetic resonance imaging (MRI) in detecting the long head of the biceps tendon (LHBT) tears in association with rotator cuff tendon tears. This study included 80 consecutive patients who underwent arthroscopic surgery for rotator cuff tendon tears. Two radiologists independently evaluated the preoperative 3T shoulder MRI for the presence of LHBT tears. The DP of MRI was evaluated using the results of arthroscopy as the reference standard. We also evaluated the DP of several MR signs of LHBT in detection of partial LHBT tears. Arthroscopic examination revealed 35 partial and 5 complete tears. According to the results of evaluation by reviewers 1 and 2, shoulder MRI exhibited sensitivities of 77.14 and 80 % and specificities of 71.11 and 73.33 % in detection of partial LHBT tears and sensitivities of 80 and 100 % and a specificity of 100% (both) in detection of complete LHBT tears. In detecting partial LHBT tears, increased T2 signal intensity of the LHBT exhibited high sensitivities (reviewers 1 and 2; 82.85 and 80 %, respectively) and the presence of intratendinous defects or C-signs exhibited the highest specificities (reviewers 1 and 2; 95.55 and 93.33 %, respectively), followed by abnormalities in shape and outer margins of the LHBT (reviewers 1 and 2; 91.11 and 82 %; 91.11 and 86.66 %, respectively). Non-contrast-enhanced 3T shoulder MRI is potentially highly accurate in detection of complete LHBT tears, but moderately accurate in detection of partial LHBT tears. (orig.)

  16. Diagnostic accuracy of 3T conventional shoulder MRI in the detection of the long head of the biceps tendon tears associated with rotator cuff tendon tears

    International Nuclear Information System (INIS)

    Lee, Ro Woon; Choi, Soo-Jung; Ahn, Jae Hong; Shin, Dong Rock; Kang, Chae Hoon; Lee, Man Ho; Lee, Ki Won

    2016-01-01

    To evaluate the diagnostic performance (DP) of 3T (3 Tesla field strength) conventional shoulder magnetic resonance imaging (MRI) in detecting the long head of the biceps tendon (LHBT) tears in association with rotator cuff tendon tears. This study included 80 consecutive patients who underwent arthroscopic surgery for rotator cuff tendon tears. Two radiologists independently evaluated the preoperative 3T shoulder MRI for the presence of LHBT tears. The DP of MRI was evaluated using the results of arthroscopy as the reference standard. We also evaluated the DP of several MR signs of LHBT in detection of partial LHBT tears. Arthroscopic examination revealed 35 partial and 5 complete tears. According to the results of evaluation by reviewers 1 and 2, shoulder MRI exhibited sensitivities of 77.14 and 80 % and specificities of 71.11 and 73.33 % in detection of partial LHBT tears and sensitivities of 80 and 100 % and a specificity of 100% (both) in detection of complete LHBT tears. In detecting partial LHBT tears, increased T2 signal intensity of the LHBT exhibited high sensitivities (reviewers 1 and 2; 82.85 and 80 %, respectively) and the presence of intratendinous defects or C-signs exhibited the highest specificities (reviewers 1 and 2; 95.55 and 93.33 %, respectively), followed by abnormalities in shape and outer margins of the LHBT (reviewers 1 and 2; 91.11 and 82 %; 91.11 and 86.66 %, respectively). Non-contrast-enhanced 3T shoulder MRI is potentially highly accurate in detection of complete LHBT tears, but moderately accurate in detection of partial LHBT tears. (orig.)

  17. The Relationship of Visual Evoked Potential Asymmetries to the Performance of Sonar Operators

    Science.gov (United States)

    1981-08-11

    also been related to EP variability. Schizophrenic adults and patients with Korsakoff’s Syndrome have shown higher evoked potential variability than...average evoked response in Korsakoff patients. J. Psychiatry Res. 6: 253-260, 1969. Santoro, T. and D. Fender. Rules for the perception of

  18. Research on rotational speed to the influence of pump as turbine

    International Nuclear Information System (INIS)

    Yang, S S; Kong, F Y; Jiang, W M; Qu, X Y

    2012-01-01

    Due to the problem of lacking hydraulic control devices, pump as turbine (PAT) has the disadvantage of optimum operation only within a small range discharge where the net head utilization and operating efficiency are the highest. Variable speed operation offers a good solution to this problem. Pump manufactures normally do not provide performance curves of their pumps working as turbines, especially when working at variable speed condition. Therefore, establishing a correlation between PAT's performance curve and rotational speed is essential. In this paper, a method of predicting PAT's performance at different rotational speeds was first developed using theoretical analysis. In the second step, a single stage centrifugal pump operated as a turbine was tested at different rotational speeds. Typical performance curves of PAT operating at variable speed condition were acquired. Finally computational fluid dynamics (CFD) had been used in this research. The accuracy of CFD prediction was proved when compared with experimental data. The validity of presented method by theoretical analysis was validated using test and CFD results.

  19. Calcific tendinitis of the long head of the biceps brachii distal to the glenohumeral joint: plain film radiographic findings.

    Science.gov (United States)

    Goldman, A B

    1989-11-01

    Calcific tendinitis is a painful condition related to deposition of hydroxyapatite crystals; it favors large joints. The shoulder, specifically the tendons of the rotator cuff and the insertion of the long head of the biceps on the superior glenoid rim, is a well-recognized location for this abnormality. The purpose of this article is to describe a second site of calcific tendinitis of the biceps, distal to the joint and corresponding to the junction of the tendon and muscle. Radiographs in 119 cases of calcific tendinitis of the shoulder, obtained between 1980 and 1988, were reviewed. Twenty had calcific tendinitis in the region of the tendon of the long head of the biceps (nine at the glenoid insertion and 11 adjacent to the humeral shaft). All 11 patients with calcific tendinitis at the more distal site had a small, homogeneous deposit adjacent to the proximal humeral shaft. The densities in these 11 cases followed the normal course of the tendon of the long head of the biceps and were therefore medial to the proximal humeral shaft on the internal rotation view, lateral to the proximal humeral shaft on the external rotation view, and anterior to the proximal humeral shaft on the axillary projection. The major differential diagnosis of calcific tendinitis of the tendon of the long head of the biceps is loose bodies trapped in the biceps tendon sheath. Although the position of the soft-tissue densities in these two entities is similar, loose bodies have an appearance of bone, and their source (degenerative arthritis or recurrent dislocations) is usually apparent. A site of calcific tendinitis distal to the glenohumeral joint that is detectable on plain films is reviewed. Accurate diagnosis depends on understanding the anatomy of the tendon of the long head of the biceps brachii. The clinical charts of the 11 patients also are summarized, with emphasis on the association between the roentgen finding and bicipital tendinitis and impingement syndrome.

  20. Conduction velocity of the human spinothalamic tract as assessed by laser evoked potentials

    DEFF Research Database (Denmark)

    Cruccu, G.; Iannetti, G. D.; Agostino, R.

    2000-01-01

    To study the conduction velocity of the spinothalamic tract (STT) we delivered CO2 laser pulses, evoking pinprick sensations, to the skin overlying the vertebral spinous processes at different spinal levels from C5 to T10 and recorded evoked potentials (LEPs) in 15 healthy human subjects...

  1. Evidence that 5-hydroxytryptamine3 receptors mediate cytotoxic drug and radiation-evoked emesis

    International Nuclear Information System (INIS)

    Miner, W.D.; Sanger, G.J.; Turner, D.H.

    1987-01-01

    The involvement of 5-hydroxytryptamine (5-HT) 5-HT 3 receptors in the mechanisms of severe emesis evoked by cytotoxic drugs or by total body irradiation have been studied in ferrets. Anti-emetic compounds tested were domperidone (a dopamine antagonist), metoclopramide (a gastric motility stimulant and dopamine antagonist at conventional doses, a 5-HT 3 receptor antagonist at higher doses) and BRL 24924 (a potent gastric motility stimulant and a 5-HT 3 receptor antagonist). Domperidone or metoclopramide prevented apomorphine-evoked emesis, whereas BRL 24924 did not. Similar doses of domperidone did not prevent emesis evoked by cis-platin or by total body irradiation, whereas metoclopramide or BRL 24924 greatly reduced or prevented these types of emesis. Metoclopramide and BRL 24924 also prevented emesis evoked by a combination of doxorubicin and cyclophosphamide. These results are discussed in terms of a fundamental role for 5-HT 3 receptors in the mechanisms mediating severely emetogenic cancer treatment therapies. (author)

  2. Interhemispheric Asymmetries in Visual Evoked Potential Amplitude

    Science.gov (United States)

    1980-06-12

    Layne, 1965) and of patients with Korsakoff’s syndrome (Malerstein and Callaway, 1969) . In the schizophrenics, the high variability is related to poor...communication. Malerstein, A. J., Callaway, E. Two-tone average evoked response in Korsakoff patients. J. Psychiatr. Res. 6: 253-260, 1969. Marsh, G

  3. An induction Linac approach to phase rotation of a muon bunch in the production region of μ+-μ- colliders

    International Nuclear Information System (INIS)

    Turner, W.C.

    1995-01-01

    The possibility of using an induction linac for phase rotation, or equivalently flattening the head to tail mean energy sweep, of a muon bunch in the production region of a μ + - μ - is examined. Axial spreading of an accelerating bunch is analyzed and the form of appropriate induction cell voltage waveforms is derived. A set of parametric equations for the induction accelerator structure is given and specific solutions are presented which demonstrate the technological feasibility of the induction linac approach to phase rotation

  4. Visual cortical somatosensory and brainstem auditory evoked potentials following incidental irradiation of the rhombencephalon

    Energy Technology Data Exchange (ETDEWEB)

    Nightingale, S. (Royal Victoria Infirmary, Newcastle upon Tyne (UK)); Schofield, I.S.; Dawes, P.J.D.K. (Newcastle upon Tyne Univ. (UK). Newcastle General Hospital)

    1984-01-01

    Visual, cortical somatosensory and brainstem auditory evoked potentials were recorded before incidental irradiation of the rhombencephalon during radiotherapy in and around the middle ear, and at 11 weeks and eight months after completion of treatment. No patient experienced neurological symptoms during this period. No consistent changes in evoked potentials were found. The failure to demonstrate subclinical radiation-induced demyelination suggests either that the syndrome of early-delayed radiation rhombencephalopathy occurs in an idiosyncratic manner, or that any subclinical lesions are not detectable by serial evoked potential recordings.

  5. Wave-driven Rotation in Supersonically Rotating Mirrors

    Energy Technology Data Exchange (ETDEWEB)

    A. Fetterman and N.J. Fisch

    2010-02-15

    Supersonic rotation in mirrors may be produced by radio frequency waves. The waves produce coupled diffusion in ion kinetic and potential energy. A population inversion along the diffusion path then produces rotation. Waves may be designed to exploit a natural kinetic energy source or may provide the rotation energy on their own. Centrifugal traps for fusion and isotope separation may benefit from this wave-driven rotation.

  6. Wave-driven Rotation in Supersonically Rotating Mirrors

    International Nuclear Information System (INIS)

    Fetterman, A.; Fisch, N.J.

    2010-01-01

    Supersonic rotation in mirrors may be produced by radio frequency waves. The waves produce coupled diffusion in ion kinetic and potential energy. A population inversion along the diffusion path then produces rotation. Waves may be designed to exploit a natural kinetic energy source or may provide the rotation energy on their own. Centrifugal traps for fusion and isotope separation may benefit from this wave-driven rotation.

  7. Examination of rotator cuff re-tear

    International Nuclear Information System (INIS)

    Kitahara, Hiroyuki; Yabe, Yoshihiro; Norimatsu, Takahiro; Adachi, Shinji; Sera, Keisuke

    2010-01-01

    The six-month post-operative re-tear rate in 72 arthroscopic rotator cuff repair cases was 16.3% by MRI. The re-tear rate of massive tears was 50%. We investigated the details of the re-tears by MRI and arthroscopic findings. High re-tear rates were connected with cuff tear size and fatty degeneration of muscle belly. Cases with poor cuff quality in arthroscopically showed high re-tear rate. These results suggest that surgery operation should be performed as soon as possible after diagnosis of cuff tear to obtain good results. Cases with damage of long head of the biceps (LHB) are likely to develop impingement causes of re-tears. Some type of rehabilitation is required to avoid impingement in such cases. (author)

  8. Deficits and recovery in visuospatial memory during head motion after bilateral labyrinthine lesion.

    Science.gov (United States)

    Wei, Min; Li, Nuo; Newlands, Shawn D; Dickman, J David; Angelaki, Dora E

    2006-09-01

    To keep a stable internal representation of the environment as we move, extraretinal sensory or motor cues are critical for updating neural maps of visual space. Using a memory-saccade task, we studied whether visuospatial updating uses vestibular information. Specifically, we tested whether trained rhesus monkeys maintain the ability to update the conjugate and vergence components of memory-guided eye movements in response to passive translational or rotational head and body movements after bilateral labyrinthine lesion. We found that lesioned animals were acutely compromised in generating the appropriate horizontal versional responses necessary to update the directional goal of memory-guided eye movements after leftward or rightward rotation/translation. This compromised function recovered in the long term, likely using extravestibular (e.g., somatosensory) signals, such that nearly normal performance was observed 4 mo after the lesion. Animals also lost their ability to adjust memory vergence to account for relative distance changes after motion in depth. Not only were these depth deficits larger than the respective effects on version, but they also showed little recovery. We conclude that intact labyrinthine signals are functionally useful for proper visuospatial memory updating during passive head and body movements.

  9. Music-evoked emotions in schizophrenia.

    Science.gov (United States)

    Abe, Daijyu; Arai, Makoto; Itokawa, Masanari

    2017-07-01

    Previous studies have reported that people with schizophrenia have impaired musical abilities. Here we developed a simple music-based assay to assess patient's ability to associate a minor chord with sadness. We further characterize correlations between impaired musical responses and psychiatric symptoms. We exposed participants sequentially to two sets of sound stimuli, first a C-major progression and chord, and second a C-minor progression and chord. Participants were asked which stimulus they associated with sadness, the first set, the second set, or neither. The severity of psychiatric symptoms was assessed using the Positive and Negative Syndrome Scale (PANSS). Study participants were 29 patients diagnosed with schizophrenia and 29 healthy volunteers matched in age, gender and musical background. 37.9% (95% confidence interval [CI]:19.1-56.7) of patients with schizophrenia associated the minor chord set as sad, compared with 97.9% (95%CI: 89.5-103.6) of controls. Four patients were diagnosed with treatment-resistant schizophrenia, and all four failed to associate the minor chord with sadness. Patients who did not recognize minor chords as sad had significantly higher scores on all PANSS subscales. A simple test allows music-evoked emotions to be assessed in schizophrenia patient, and may show potential relationships between music-evoked emotions and psychiatric symptoms. Copyright © 2016. Published by Elsevier B.V.

  10. Right hemispheric dominance of visual phenomena evoked by intracerebral stimulation of the human visual cortex.

    Science.gov (United States)

    Jonas, Jacques; Frismand, Solène; Vignal, Jean-Pierre; Colnat-Coulbois, Sophie; Koessler, Laurent; Vespignani, Hervé; Rossion, Bruno; Maillard, Louis

    2014-07-01

    Electrical brain stimulation can provide important information about the functional organization of the human visual cortex. Here, we report the visual phenomena evoked by a large number (562) of intracerebral electrical stimulations performed at low-intensity with depth electrodes implanted in the occipito-parieto-temporal cortex of 22 epileptic patients. Focal electrical stimulation evoked primarily visual hallucinations with various complexities: simple (spot or blob), intermediary (geometric forms), or complex meaningful shapes (faces); visual illusions and impairments of visual recognition were more rarely observed. With the exception of the most posterior cortical sites, the probability of evoking a visual phenomenon was significantly higher in the right than the left hemisphere. Intermediary and complex hallucinations, illusions, and visual recognition impairments were almost exclusively evoked by stimulation in the right hemisphere. The probability of evoking a visual phenomenon decreased substantially from the occipital pole to the most anterior sites of the temporal lobe, and this decrease was more pronounced in the left hemisphere. The greater sensitivity of the right occipito-parieto-temporal regions to intracerebral electrical stimulation to evoke visual phenomena supports a predominant role of right hemispheric visual areas from perception to recognition of visual forms, regardless of visuospatial and attentional factors. Copyright © 2013 Wiley Periodicals, Inc.

  11. Temporal processing and long-latency auditory evoked potential in stutterers.

    Science.gov (United States)

    Prestes, Raquel; de Andrade, Adriana Neves; Santos, Renata Beatriz Fernandes; Marangoni, Andrea Tortosa; Schiefer, Ana Maria; Gil, Daniela

    Stuttering is a speech fluency disorder, and may be associated with neuroaudiological factors linked to central auditory processing, including changes in auditory processing skills and temporal resolution. To characterize the temporal processing and long-latency auditory evoked potential in stutterers and to compare them with non-stutterers. The study included 41 right-handed subjects, aged 18-46 years, divided into two groups: stutterers (n=20) and non-stutters (n=21), compared according to age, education, and sex. All subjects were submitted to the duration pattern tests, random gap detection test, and long-latency auditory evoked potential. Individuals who stutter showed poorer performance on Duration Pattern and Random Gap Detection tests when compared with fluent individuals. In the long-latency auditory evoked potential, there was a difference in the latency of N2 and P3 components; stutterers had higher latency values. Stutterers have poor performance in temporal processing and higher latency values for N2 and P3 components. Copyright © 2017 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  12. Temporal processing and long-latency auditory evoked potential in stutterers

    Directory of Open Access Journals (Sweden)

    Raquel Prestes

    Full Text Available Abstract Introduction: Stuttering is a speech fluency disorder, and may be associated with neuroaudiological factors linked to central auditory processing, including changes in auditory processing skills and temporal resolution. Objective: To characterize the temporal processing and long-latency auditory evoked potential in stutterers and to compare them with non-stutterers. Methods: The study included 41 right-handed subjects, aged 18-46 years, divided into two groups: stutterers (n = 20 and non-stutters (n = 21, compared according to age, education, and sex. All subjects were submitted to the duration pattern tests, random gap detection test, and long-latency auditory evoked potential. Results: Individuals who stutter showed poorer performance on Duration Pattern and Random Gap Detection tests when compared with fluent individuals. In the long-latency auditory evoked potential, there was a difference in the latency of N2 and P3 components; stutterers had higher latency values. Conclusion: Stutterers have poor performance in temporal processing and higher latency values for N2 and P3 components.

  13. Pattern visual evoked potentials in malingering.

    Science.gov (United States)

    Nakamura, A; Akio, T; Matsuda, E; Wakami, Y

    2001-03-01

    We previously developed a new method for estimating objective visual acuity by means of pattern visual evoked potentials (PVEP). In this study, this method was applied to the diagnosis of malingering. Six patients ranging in age from 40 to 54 years (mean 47 years) with suspected malingering were evaluated by means of the visual evoked potential test, optokinetic nystagmus (OKN) inhibition test, and the visual field test. In the PVEP study, the stimulus consisted of black and white checkerboards (39', 26', 15', and 9') with a visual angle of 8 degrees, contrast level of 15%, and a frequency of 0.7 Hz. One hundred PVEP responses were averaged per session. Routine ophthalmic examinations were normal in all patients. Five patients had a tubularly constricted visual field, and the remaining patient had a normal visual field. The objective visual acuities of the six patients estimated from PVEP were better than their subjective visual acuities estimated with Landolt rings. Among a variety of psychophysical and electrophysiologic ancillary tests, we consider our PVEP method a useful method for objectively determining visual acuity in a patient with signs of ocular malingering.

  14. Brainstem auditory evoked potentials in horses

    Directory of Open Access Journals (Sweden)

    Juliana Almeida Nogueira da Gama

    2016-04-01

    Full Text Available ABSTRACT: The brainstem auditory evoked potential (BAEP evaluates the integrity of the auditory pathways to the brainstem. The aim of this study was to evoke BAEPs in 21 clinically normal horses. The animals were sedated with detomidine hydrochloride (0.013mg.kg-1 BW. Earphones were inserted and rarefaction clicks at 90 dB and noise masking at 40 dB were used. After performing the test, the latencies of waves (I, II, III, IV, and V and interpeaks(I-III, III-V, and I-V were identified. The mean latencies of the waves were as follows: wave I, 2.4 ms; wave II, 2.24 ms; wave III, 3.61ms; wave IV, 4.61ms; and wave V, 5.49ms. The mean latencies of the interpeaks were as follows: I-III, 1.37ms; III-V, 1.88ms; and I-V, 3.26ms. This is the first study using BAEPs in horses in Brazil, and the observed latencies will be used as normative data for the interpretation of tests performed on horses with changes related to auditory system or neurologic abnormalities.

  15. Multiple-Nozzle Spray Head Applies Foam Insulation

    Science.gov (United States)

    Walls, Joe T.

    1993-01-01

    Spray head equipped with four-nozzle turret mixes two reactive components of polyurethane and polyisocyanurate foam insulating material and sprays reacting mixture onto surface to be insulated. If nozzle in use becomes clogged, fresh one automatically rotated into position, with minimal interruption of spraying process. Incorporates features recirculating and controlling pressures of reactive components to maintain quality of foam by ensuring proper blend at outset. Also used to spray protective coats on or in ships, aircraft, and pipelines. Sprays such reactive adhesives as epoxy/polyurethane mixtures. Components of spray contain solid-particle fillers for strength, fire retardance, toughness, resistance to abrasion, or radar absorption.

  16. Clinical and evoked pain, personality traits, and emotional states: can familial confounding explain the associations?

    Science.gov (United States)

    Strachan, Eric; Poeschla, Brian; Dansie, Elizabeth; Succop, Annemarie; Chopko, Laura; Afari, Niloofar

    2015-01-01

    Pain is a complex phenomenon influenced by context and person-specific factors. Affective dimensions of pain involve both enduring personality traits and fleeting emotional states. We examined how personality traits and emotional states are linked with clinical and evoked pain in a twin sample. 99 female twin pairs were evaluated for clinical and evoked pain using the McGill Pain Questionnaire (MPQ) and dolorimetry, and completed the 120-item International Personality Item Pool (IPIP), the Positive and Negative Affect Scale (PANAS), and ratings of stress and mood. Using a co-twin control design we examined a) the relationship of personality traits and emotional states with clinical and evoked pain and b) whether genetics and common environment (i.e. familial factors) may account for the associations. Neuroticism was associated with the sensory component of the MPQ; this relationship was not confounded by familial factors. None of the emotional state measures was associated with the MPQ. PANAS negative affect was associated with lower evoked pressure pain threshold and tolerance; these associations were confounded by familial factors. There were no associations between IPIP traits and evoked pain. A relationship exists between neuroticism and clinical pain that is not confounded by familial factors. There is no similar relationship between negative emotional states and clinical pain. In contrast, the relationship between negative emotional states and evoked pain is strong while the relationship with enduring personality traits is weak. The relationship between negative emotional states and evoked pain appears to be non-causal and due to familial factors. Copyright © 2014 Elsevier Inc. All rights reserved.

  17. Visual cortical somatosensory and brainstem auditory evoked potentials following incidental irradiation of the rhombencephalon

    International Nuclear Information System (INIS)

    Nightingale, S.; Schofield, I.S.; Dawes, P.J.D.K.

    1984-01-01

    Visual, cortical somatosensory and brainstem auditory evoked potentials were recorded before incidental irradiation of the rhombencephalon during radiotherapy in and around the middle ear, and at 11 weeks and eight months after completion of treatment. No patient experienced neurological symptoms during this period. No consistent changes in evoked potentials were found. The failure to demonstrate subclinical radiation-induced demyelination suggests either that the syndrome of early-delayed radiation rhombencephalopathy occurs in an idiosyncratic manner, or that any subclinical lesions are not detectable by serial evoked potential recordings. (author)

  18. Player and Game Characteristics and Head Impacts in Female Youth Ice Hockey Players.

    Science.gov (United States)

    Reed, Nick; Taha, Tim; Greenwald, Richard; Keightley, Michelle

    2017-08-01

      Despite the growing popularity of ice hockey among female youth and interest in the biomechanics of head impacts in sport, the head impacts sustained by this population have yet to be characterized.   To describe the number of, biomechanical characteristics of, and exposure to head impacts of female youth ice hockey players during competition and to investigate the influences of player and game characteristics on head impacts.   Cohort study.   Twenty-seven female youth ice hockey players (mean age = 12.5 ± 0.52 years) wore instrumented ice hockey helmets during 66 ice hockey games over a 3-year period. Data specific to player, game, and biomechanical head impact characteristics were recorded. A multiple regression analysis identified factors most associated with head impacts of greater frequency and severity.   A total of 436 total head impacts were sustained during 6924 minutes of active ice hockey participation (0.9 ± 0.6 impacts per player per game; range, 0-2.1). A higher body mass index (BMI) significantly predicted a higher number of head impacts sustained per game (P = .008). Linear acceleration of head impacts was greater in older players and those who played the forward position, had a greater BMI, and spent more time on the ice (P = .008), whereas greater rotational acceleration was present in older players who had a greater BMI and played the forward position (P = .008). During tournament games, increased ice time predicted increased severity of head impacts (P = .03).   This study reveals for the first time that head impacts are occurring in female youth ice hockey players, albeit at a lower rate and severity than in male youth ice hockey players, despite the lack of intentional body checking.

  19. Proprioceptive evoked potentials in man

    DEFF Research Database (Denmark)

    Arnfred, S; Chen, A C; Eder, Derek N

    2000-01-01

    We studied cerebral evoked potentials on the scalp to the stimulation of the right hand from a change in weight of 400-480 g in ten subjects. Rise-time was 20g/10 ms, Inter Stimulus Interval 2s and stimulus duration was 100 ms. The cerebral activations were a double positive contralateral C3'/P70......). Further studies of the PEP are needed to assess the influence of load manipulations and of muscle contraction and to explore the effect of attentional manipulation....

  20. Differential effect of ketamine and lidocaine on spontaneous and mechanical evoked pain in patients with nerve injury pain

    DEFF Research Database (Denmark)

    Gottrup, Hanne; Bach, Flemming Winther; Juhl, Gitte Irene

    2006-01-01

    ketamine, an N-methyl-D-aspartate receptor antagonist and lidocaine, a sodium channel blocker, on spontaneous pain, brush-evoked pain, and pinprick-evoked pain in patients with nerve injury pain. METHODS: Twenty patients participated in two randomized, double-blinded, placebo-controlled, crossover...... experiments in which they, on four different days, received a 30-minute intravenous infusion of ketamine (0.24 mg/kg), lidocaine (5 mg/kg), or saline. Ongoing pain, pain evoked by brush and repetitive pinprick stimuli, and acetone was measured before, during, and after infusion. RESULTS: Ketamine...... significantly reduced ongoing pain and evoked pain to brush and pinprick, whereas lidocaine only reduced evoked pain to repetitive pinprick stimuli. In individual patients, there was no correlation between the pain-relieving effect of lidocaine and ketamine on ongoing or mechanically evoked pains. CONCLUSIONS...

  1. Chronic Degeneration Leads to Poor Healing of Repaired Massive Rotator Cuff Tears in Rats.

    Science.gov (United States)

    Killian, Megan L; Cavinatto, Leonardo M; Ward, Samuel R; Havlioglu, Necat; Thomopoulos, Stavros; Galatz, Leesa M

    2015-10-01

    Chronic rotator cuff tears present a clinical challenge, often with poor outcomes after surgical repair. Degenerative changes to the muscle, tendon, and bone are thought to hinder healing after surgical repair; additionally, the ability to overcome degenerative changes after surgical repair remains unclear. The purpose of this study was to evaluate healing outcomes of muscle, tendon, and bone after tendon repair in a model of chronic rotator cuff disease and to compare these outcomes to those of acute rotator cuff injuries and repair. The hypothesis was that degenerative rotator cuff changes associated with chronic multitendon tears and muscle unloading would lead to poor structural and mechanical outcomes after repair compared with acute injuries and repair. Controlled laboratory study. Chronic rotator cuff injuries, induced via detachment of the supraspinatus (SS) and infraspinatus (IS) tendons and injection of botulinum toxin A into the SS and IS muscle bellies, were created in the shoulders of rats. After 8 weeks of injury, tendons were surgically reattached to the humeral head, and an acute, dual-tendon injury and repair was performed on the contralateral side. After 8 weeks of healing, muscles were examined histologically, and tendon-to-bone samples were examined microscopically, histologically, and biomechanically and via micro-computed tomography. All repairs were intact at the time of dissection, with no evidence of gapping or ruptures. Tendon-to-bone healing after repair in our chronic injury model led to reduced bone quality and morphological disorganization at the repair site compared with acute injuries and repair. SS and IS muscles were atrophic at 8 weeks after repair of chronic injuries, indicating incomplete recovery after repair, whereas SS and IS muscles exhibited less atrophy and degeneration in the acute injury group at 8 weeks after repair. After chronic injuries and repair, humeral heads had decreased total mineral density and an altered

  2. Rotating flow

    CERN Document Server

    Childs, Peter R N

    2010-01-01

    Rotating flow is critically important across a wide range of scientific, engineering and product applications, providing design and modeling capability for diverse products such as jet engines, pumps and vacuum cleaners, as well as geophysical flows. Developed over the course of 20 years' research into rotating fluids and associated heat transfer at the University of Sussex Thermo-Fluid Mechanics Research Centre (TFMRC), Rotating Flow is an indispensable reference and resource for all those working within the gas turbine and rotating machinery industries. Traditional fluid and flow dynamics titles offer the essential background but generally include very sparse coverage of rotating flows-which is where this book comes in. Beginning with an accessible introduction to rotating flow, recognized expert Peter Childs takes you through fundamental equations, vorticity and vortices, rotating disc flow, flow around rotating cylinders and flow in rotating cavities, with an introduction to atmospheric and oceanic circul...

  3. Rotational seismology

    Science.gov (United States)

    Lee, William H K.

    2016-01-01

    Rotational seismology is an emerging study of all aspects of rotational motions induced by earthquakes, explosions, and ambient vibrations. It is of interest to several disciplines, including seismology, earthquake engineering, geodesy, and earth-based detection of Einstein’s gravitation waves.Rotational effects of seismic waves, together with rotations caused by soil–structure interaction, have been observed for centuries (e.g., rotated chimneys, monuments, and tombstones). Figure 1a shows the rotated monument to George Inglis observed after the 1897 Great Shillong earthquake. This monument had the form of an obelisk rising over 19 metres high from a 4 metre base. During the earthquake, the top part broke off and the remnant of some 6 metres rotated about 15° relative to the base. The study of rotational seismology began only recently when sensitive rotational sensors became available due to advances in aeronautical and astronomical instrumentations.

  4. Auditory and visual evoked potentials during hyperoxia

    Science.gov (United States)

    Smith, D. B. D.; Strawbridge, P. J.

    1974-01-01

    Experimental study of the auditory and visual averaged evoked potentials (AEPs) recorded during hyperoxia, and investigation of the effect of hyperoxia on the so-called contingent negative variation (CNV). No effect of hyperoxia was found on the auditory AEP, the visual AEP, or the CNV. Comparisons with previous studies are discussed.

  5. Evaluation of the Effusion within Biceps Long Head Tendon Sheath Using Ultrasonography

    Science.gov (United States)

    Park, In; Lee, Hyo-Jin; Kim, Sung-Eun; Bae, Sung-Ho; Lee, Kwang-Yeol; Park, Kwang-Sun

    2015-01-01

    Background Many shoulder diseases are related to glenohumeral joint synovitis and effusion. The purpose of the present study is to detect effusion within the biceps long head tendon sheath as the sign of glenohumeral joint synovitis using ultrasonography, and to evaluate the clinical meaning of effusion within the biceps long head tendon sheath. Methods A consecutive series of 569 patients who underwent ultrasonography for shoulder pain were reviewed retrospectively and ultimately, 303 patients were included. The authors evaluated the incidence and amount of the effusion within the biceps long head tendon sheath on the ultrasonographic short axis view. Furthermore, the authors evaluated the correlation between the amount of effusion within the biceps long head tendon sheath and the range of motion and the functional score. Results The effusion within the biceps long head tendon sheath was detected in 58.42% of the patients studied: 69.23% in adhesive capsulitis, 56.69% in rotator cuff tear, 41.03% in calcific tendinitis, and 33.33% in biceps tendinitis. The average amount of the effusion within the biceps long head tendon sheath was 1.7 ± 1.6 mm, and it was measured to be the largest in adhesive capsulitis. The amount of effusion within biceps long head tendon sheath showed a moderate to high degree of correlation with the range of motion, and a low degree of correlation with the functional score and visual analogue scale for pain in each type of shoulder disease. Conclusions The effusion within the biceps long head tendon sheath is closely related to the range of motion and clinical scores in patients with painful shoulders. Ultrasonographic detection of the effusion within the biceps long head tendon sheath might be a simple and easy method to evaluate shoulder function. PMID:26330958

  6. Identification of rotating and vibrating tetrahedrons in the heavy nucleus {sup 208}Pb

    Energy Technology Data Exchange (ETDEWEB)

    Heusler, A.

    2017-11-15

    Ten known states in the heavy nucleus {sup 208}Pb at 2.6 < E{sub x} < 7.9 MeV are described by rotating and vibrating tetrahedrons. The 3{sup -} and 4{sup +} yrast states are the first members of the rotational band. A 2{sup ±} doublet state with the 2{sup +} yrast state as one member and the newly recognized 2{sup -} yrast state as the other member, the 1{sup -} yrast state, and the third 0{sup +} state are the heads of the three elementary tetrahedral rotating and vibrating bands. The newly recognized state at E{sub x} = 4142 keV was assigned spin 2 in 1975 and is suggested to have negative parity by the absent {sup 208}Pb(α, α{sup '}) excitation. Four more states at 5.7 < E{sub x} < 7.9 MeV are identified as the next members of the three elementary tetrahedral rotating and vibrating bands. The ambiguous spin assignment to the state at E{sub x} = 7020 keV is settled with 3{sup -}, the state at E{sub x} = 7137 keV is assigned 4{sup -}. (orig.)

  7. Arthroscopic treatment of secondary rotator cuff damage after shoulder hemiarthroplasty (case report

    Directory of Open Access Journals (Sweden)

    S. Y. Dokolin

    2015-01-01

    Full Text Available Anatomical shoulder arthroplasty is an effective treatment for patients with primary deforming arthritis, rheumatoid arthritis and aseptic necrosis of the humeral head. However this kind of surgery is associated with high risk of complications, and within five-year follow-up the incidence of complications increases. The authors described a clinical case illustrating one of these complications - secondary rotator cuff damage after shoulder hemiarthroplasty. The tear was verified using radiological methods and arthroscopy. They performed arthroscopic rotator cuff repair using suture anchors in order to alleviate pain and preserve shoulder functions. If there are no signs of endoprosthetic instability and coracoacromial ligament is preserved, arthroscopic treatment of such damages extends the time of limb function preserving the endoprosthesis. Patients should not raise their arms above the horizontal level.

  8. The functional role of dorso-lateral premotor cortex during mental rotation: an event-related fMRI study separating cognitive processing steps using a novel task paradigm.

    Science.gov (United States)

    Lamm, Claus; Windischberger, Christian; Moser, Ewald; Bauer, Herbert

    2007-07-15

    Subjects deciding whether two objects presented at angular disparity are identical or mirror versions of each other usually show response times that linearly increase with the angle between objects. This phenomenon has been termed mental rotation. While there is widespread agreement that parietal cortex plays a dominant role in mental rotation, reports concerning the involvement of motor areas are less consistent. From a theoretical point of view, activation in motor areas suggests that mental rotation relies upon visuo-motor rather than visuo-spatial processing alone. However, the type of information that is processed by motor areas during mental rotation remains unclear. In this study we used event-related fMRI to assess whether activation in parietal and dorsolateral premotor areas (dPM) during mental rotation is distinctively related to processing spatial orientation information. Using a newly developed task paradigm we explicitly separated the processing steps (encoding, mental rotation proper and object matching) required by mental rotation tasks and additionally modulated the amount of spatial orientation information that had to be processed. Our results show that activation in dPM during mental rotation is not strongly modulated by the processing of spatial orientation information, and that activation in dPM areas is strongest during mental rotation proper. The latter finding suggests that dPM is involved in more generalized processes such as visuo-spatial attention and movement anticipation. We propose that solving mental rotation tasks is heavily dependent upon visuo-motor processes and evokes neural processing that may be considered as an implicit simulation of actual object rotation.

  9. Heads Up

    Science.gov (United States)

    ... Connect with Us HEADS UP Apps Reshaping the Culture Around Concussion in Sports Get HEADS UP on Your Web Site Concussion ... HEADS UP on your web site! Create a culture of safety for young athletes Officials, learn how you can ... UP to Providers HEADS UP to Youth Sports HEADS UP to School Sports HEADS UP to ...

  10. Behavioral Outcomes Differ Between Rotational Acceleration and Blast Mechanisms of Mild Traumatic Brain Injury

    Directory of Open Access Journals (Sweden)

    Brian D. Stemper

    2016-03-01

    Full Text Available Mild traumatic brain injury (mTBI can result from a number of mechanisms, including blunt impact, head rotational acceleration, exposure to blast, and penetration of projectiles. Mechanism is likely to influence the type, severity, and chronicity of outcomes. The objective of this study was to determine differences in the severity and time-course of behavioral outcomes following blast and rotational mTBI. The Medical College of Wisconsin (MCW Rotational Injury model and a shock tube model of primary blast injury were used to induce mTBI in rats and behavioral assessments were conducted within the first week, as well as 30 and 60 days following injury. Acute recovery time demonstrated similar increases over protocol-matched shams, indicating acute injury severity equivalence between the two mechanisms. Post-injury behavior in the elevated plus maze demonstrated differing trends, with rotationally injured rats acutely demonstrating greater activity, whereas blast-injured rats had decreased activity that developed at chronic time points. Similarly, blast-injured rats demonstrated trends associated with cognitive deficits that were not apparent following rotational injuries. These findings demonstrate that rotational and blast injury result in behavioral changes with different qualitative and temporal manifestations. Whereas rotational injury was characterized by a rapidly emerging phenotype consistent with behavioral disinhibition, blast injury was associated with emotional and cognitive differences that were not evident acutely, but developed later, with an anxiety-like phenotype still present in injured animals at our most chronic measurements.

  11. COMPARISON OF A HEAD MOUNTED IMPACT MEASUREMENT DEVICE TO THE HYBRID III ANTHROPOMORPHIC TESTING DEVICE IN A CONTROLLED LABORATORY SETTING.

    Science.gov (United States)

    Schussler, Eric; Stark, David; Bolte, John H; Kang, Yun Seok; Onate, James A

    2017-08-01

    Reports estimate that 1.6 to 3.8 million cases of concussion occur in sports and recreation each year in the United States. Despite continued efforts to reduce the occurrence of concussion, the rate of diagnosis continues to increase. The mechanisms of concussion are thought to involve linear and rotational head accelerations and velocities. One method of quantifying the kinematics experienced during sport participation is to place measurement devices into the athlete's helmet or directly on the athlete's head. The purpose of this research to determine the accuracy of a head mounted device for measuring the head accelerations experienced by the wearer. This will be accomplished by identifying the error in Peak Linear Acceleration (PLA), Peak Rotational Acceleration (PRA) and Peak Rotational Velocity (PRV) of the device. Laboratory study. A helmeted Hybrid III 50th percentile male headform was impacted via a pneumatic ram from the front, side, rear, front oblique and rear oblique at speeds from 1.5 to 5 m/s. The X2 Biosystems xPatch® (Seattle, WA) sensor was placed on the headform's right side at the approximate location of the mastoid process. Measures of PLA, PRA, PRV from the xPatch ® and Hybrid III were analyzed for Root Mean Square Error (RMSE), and Absolute and Relative Error (AE, RE). Seventy-six impacts were analyzed. All measures of correlation, fixed through the origin, were found to be strong: PLA R 2 =0.967 pstandard yet above the average error of testing devices in both PLA and PRA, but a low error in PRV. PLA measures from the xPatch® system demonstrated a high level of correlation with the PLA data from the Hybrid III mounted data collection system. 3.

  12. Anatomy of the capsulolabral complex and rotator interval related to glenohumeral instability.

    Science.gov (United States)

    Itoigawa, Yoshiaki; Itoi, Eiji

    2016-02-01

    The glenohumeral joint with instability is a common diagnosis that often requires surgery. The aim of this review was to present an overview of the anatomy of the glenohumeral joint with emphasis on instability based on the current literature and to describe the detailed anatomy and anatomical variants of the glenohumeral joint associated with anterior and posterior shoulder instability. A review was performed using PubMed/MEDLINE using key words: Search terms were "glenohumeral", "shoulder instability", "cadaver", "rotator interval", "anatomy", and "anatomical study". During the last decade, the interest in both arthroscopic repair techniques and surgical anatomy of the glenohumeral ligament (superior, middle, and inferior), labrum, and rotator interval has increased. Understanding of the rotator interval and attachment of the inferior glenohumeral ligament on the glenoid or humeral head have evolved significantly. The knowledge of the detailed anatomy and anatomical variations is essential for the surgeon in order to understand the pathology, make a correct diagnosis of instability, and select proper treatment options. Proper understanding of anatomical variants can help us avoid misdiagnosis. Level of evidence V.

  13. Influence of Head and Neck Position on Oropharyngeal Leak Pressure and Cuff Position with the ProSeal Laryngeal Mask Airway and the I-Gel: A Randomized Clinical Trial

    Directory of Open Access Journals (Sweden)

    Sandeep Kumar Mishra

    2015-01-01

    Full Text Available Background. This study was designed to assess and compare the effect of head and neck position on the oropharyngeal leak pressures and cuff position (employing fibreoptic view of the glottis and ventilation scores between ProSeal LMA and the I-gel. Material and Methods. After induction of anesthesia, the supraglottic device was inserted and ventilation confirmed. The position of the head was randomly changed from neutral to flexion, extension, and lateral rotation (left. The oropharyngeal leak pressures, fibreoptic view of glottis, ventilation scores, and delivered tidal volumes and end tidal CO2 were noted in all positions. Results. In both groups compared with neutral position, oropharyngeal leak pressures were significantly higher with flexion and lower with extension but similar with rotation of head and neck. However the oropharyngeal leak pressure was significantly higher for ProSeal LMA compared with the I-gel in all positions. Peak airway pressures were significantly higher with flexion in both groups (however this did not affect ventilation, lower with extension in ProSeal group, and comparable in I-gel group but did not change significantly with rotation of head and neck in both groups. Conclusion. Effective ventilation can be done with both ProSeal LMA and I-gel with head in all the above positions. ProSeal LMA has a better margin of safety than I-gel due to better sealing pressures except in flexion where the increase in airway pressure is more with the former. Extreme precaution should be taken in flexion position in ProSeal LMA.

  14. Auditory brainstem activity and development evoked by apical versus basal cochlear implant electrode stimulation in children.

    Science.gov (United States)

    Gordon, K A; Papsin, B C; Harrison, R V

    2007-08-01

    The role of apical versus basal cochlear implant electrode stimulation on central auditory development was examined. We hypothesized that, in children with early onset deafness, auditory development evoked by basal electrode stimulation would differ from that evoked more apically. Responses of the auditory nerve and brainstem, evoked by an apical and a basal implant electrode, were measured over the first year of cochlear implant use in 50 children with early onset severe to profound deafness who used hearing aids prior to implantation. Responses at initial stimulation were of larger amplitude and shorter latency when evoked by the apical electrode. No significant effects of residual hearing or age were found on initial response amplitudes or latencies. With implant use, responses evoked by both electrodes showed decreases in wave and interwave latencies reflecting decreased neural conduction time through the brainstem. Apical versus basal differences persisted with implant experience with one exception; eIII-eV interlatency differences decreased with implant use. Acute stimulation shows prolongation of basally versus apically evoked auditory nerve and brainstem responses in children with severe to profound deafness. Interwave latencies reflecting neural conduction along the caudal and rostral portions of the brainstem decreased over the first year of implant use. Differences in neural conduction times evoked by apical versus basal electrode stimulation persisted in the caudal but not rostral brainstem. Activity-dependent changes of the auditory brainstem occur in response to both apical and basal cochlear implant electrode stimulation.

  15. Pictorial essay: Vascular interventions in extra cranial head and neck

    Directory of Open Access Journals (Sweden)

    Suyash S Kulkarni

    2012-01-01

    Full Text Available Medicine is an ever changing field and interventional radiology (IR procedures are becoming increasingly popular because of high efficacy and its minimally invasive nature of the procedure. Management of disease processes in the extra cranial head and neck (ECHN has always been a challenge due to the complex anatomy of the region. Cross sectional imaging of the ECHN has grown and evolved tremendously and occupies a pivotal and integral position in the clinical management of variety of head and neck pathologies. Advances in angiographic technologies including flat panel detector systems, biplane, and 3-dimensional rotational angiography have consolidated and expanded the role of IR in the management of various ECHN pathologies. The ECHN is at cross roads between the origins of great vessels and the cerebral vasculature. Thorough knowledge of functional and technical aspects of neuroangiography is essential before embarking on head and neck vascular interventions. The vessels of the head and neck can be involved by infectious and inflammatory conditions, get irradiated during radiotherapy and injured due to trauma or iatrogenic cause. The ECHN is also a common site for various hypervascular neoplasms and vascular malformations, which can be treated with endovascular and percutaneous embolization. This pictorial essay provides a review of variety of ECHN pathologies which were managed by various IR procedures using different approaches.

  16. Where Is the Ulnar Styloid Process? Identification of the Absolute Location of the Ulnar Styloid Process Based on CT and Verification of Neutral Forearm Rotation on Lateral Radiographs of the Wrist.

    Science.gov (United States)

    Shin, Seung-Han; Lee, Yong-Suk; Kang, Jin-Woo; Noh, Dong-Young; Jung, Joon-Yong; Chung, Yang-Guk

    2018-03-01

    The location of the ulnar styloid process can be confusing because the radius and the hand rotate around the ulna. The purpose of this study was to identify the absolute location of the ulnar styloid process, which is independent of forearm pronation or supination, to use it as a reference for neutral forearm rotation on lateral radiographs of the wrist. Computed tomography (CT) images of 23 forearms taken with elbow flexion of 70° to 90° were analyzed. The axial CT images were reconstructed to be perpendicular to the distal ulnar shaft. The absolute location of the ulnar styloid process in this study was defined as the position of the ulnar styloid process on the axial plane of the ulnar head relative to the long axis of the humeral shaft with the elbow set in the position for standard lateral radiographs of the wrist. To identify in which direction the ulnar styloid is located on the axial plane of the ulnar head, the angle between "the line of humeral long axis projected on the axial plane of the ulna" and "the line passing the center of the ulnar head and the center of the ulnar styloid" was measured (ulnar styloid direction angle). To identify how volarly or dorsally the ulnar styloid should appear on the true lateral view of the wrist, the ratio of "the volar-dorsal diameter of the ulnar head" and "the distance between the volar-most aspect of the ulnar head and the center of the ulnar styloid" was calculated (ulnar styloid location ratio). The mean ulnar styloid direction angle was 12° dorsally. The mean ulnar styloid location ratio was 1:0.55. The ulnar styloid is located at nearly the ulnar-most (the opposite side of the humerus with the elbow flexed) and slightly dorsal aspects of the ulnar head on the axial plane. It should appear almost midway (55% dorsally) from the ulnar head on the standard lateral view of the wrist in neutral forearm rotation. These location references could help clinicians determine whether the forearm is in neutral or rotated

  17. Do ambient urban odors evoke basic emotions?

    Directory of Open Access Journals (Sweden)

    Sandra Theresia Weber-Glass

    2014-04-01

    Full Text Available Fragrances, such as plant odors, have been shown to evoke autonomic response patterns associated with Ekman’s (Ekman et al., 1983 basic emotions happiness, surprise, anger, fear, sadness and disgust. Inducing positive emotions by odors in highly frequented public spaces could serve to improve the quality of life in urban environments. Thus, the present study evaluated the potency of ambient odors connoted with an urban environment to evoke basic emotions on an autonomic and cognitive response level. Synthetic mixtures representing the odors of disinfectant, candles / bees wax, summer air, burnt smell, vomit and musty smell as well as odorless water as a control were presented five times in random order to 30 healthy, non-smoking human subjects with intact sense of smell. Skin temperature, skin conductance, breathing rate, forearm muscle activity, blink rate and heart rate were recorded simultaneously. Subjects rated the odors in terms of pleasantness, intensity and familiarity and gave verbal labels to each odor as well as cognitive associations with the basic emotions. The results showed that the amplitude of the skin conductance response varied as a function of odor presentation. Burnt smell and vomit elicited significantly higher electrodermal responses than summer air. Also, a negative correlation was revealed between the amplitude of the skin conductance response and hedonic odor valence indicating that the magnitude of the electrodermal response increased with odor unpleasantness. The analysis of the cognitive associations between odors and basic emotions showed that candles / bees wax and summer air were specifically associated with happiness whereas burnt smell and vomit were uniquely associated with disgust. Our findings suggest that city odors may evoke specific cognitive associations of basic emotions and that autonomic activity elicited by such odors is related to odor hedonics.

  18. Effects of face/head and whole body cooling during passive heat stress on human somatosensory processing.

    Science.gov (United States)

    Nakata, Hiroki; Namba, Mari; Kakigi, Ryusuke; Shibasaki, Manabu

    2017-06-01

    We herein investigated the effects of face/head and whole body cooling during passive heat stress on human somatosensory processing recorded by somatosensory-evoked potentials (SEPs) at C4' and Fz electrodes. Fourteen healthy subjects received a median nerve stimulation at the left wrist. SEPs were recorded at normothermic baseline (Rest), when esophageal temperature had increased by ~1.2°C (heat stress: HS) during passive heating, face/head cooling during passive heating (face/head cooling: FHC), and after HS (whole body cooling: WBC). The latencies and amplitudes of P14, N20, P25, N35, P45, and N60 at C4' and P14, N18, P22, and N30 at Fz were evaluated. Latency indicated speed of the subcortical and cortical somatosensory processing, while amplitude reflected the strength of neural activity. Blood flow in the internal and common carotid arteries (ICA and CCA, respectively) and psychological comfort were recorded in each session. Increases in esophageal temperature due to HS significantly decreased the amplitude of N60, psychological comfort, and ICA blood flow in the HS session, and also shortened the latencies of SEPs (all, P body temperature. Copyright © 2017 the American Physiological Society.

  19. Evoked Electromyographically Controlled Electrical Stimulation

    Directory of Open Access Journals (Sweden)

    Mitsuhiro Hayashibe

    2016-07-01

    Full Text Available Time-variant muscle responses under electrical stimulation (ES are often problematic for all the applications of neuroprosthetic muscle control. This situation limits the range of ES usage in relevant areas, mainly due to muscle fatigue and also to changes in stimulation electrode contact conditions, especially in transcutaneous ES. Surface electrodes are still the most widely used in noninvasive applications.Electrical field variations caused by changes in the stimulation contact condition markedly affect the resulting total muscle activation levels. Fatigue phenomena under functional electrical stimulation (FES are also well known source of time-varying characteristics coming from muscle response under ES. Therefore it is essential to monitor the actual muscle state and assess the expected muscle response by ES so as to improve the current ES system in favour of adaptive muscle-response-aware FES control. To deal with this issue, we have been studying a novel control technique using evoked electromyography (eEMG signals to compensate for these muscle time-variances under ES for stable neuroprosthetic muscle control. In this perspective article, I overview the background of this topic and highlight important points to be aware of when using ES to induce the desired muscle activation regardless of the time-variance. I also demonstrate how to deal with the common critical problem of ES to move toward robust neuroprosthetic muscle control with the Evoked Electromyographically Controlled Electrical Stimulation paradigm.

  20. Controlling a stream of paranoia evoking events in a virtual reality environment.

    Science.gov (United States)

    Isnanda, Reza Giga; Brinkman, Willem-Paul; Veling, Wim; van der Gaag, Mark; Neerincx, Mark

    2014-01-01

    Although virtual reality exposure has been reported as a method to induce paranoid thought, little is known about mechanisms to control specific virtual stressors. This paper reports on a study that examines the effect of controlling the stream of potential paranoia evoking events in a virtual restaurant world. A 2-by-2 experiment with a non-clinical group (n = 24) was conducted with as two within-subject factors: (1) the cycle time (short/long) for when the computer considers activation of a paranoia evoking event and (2) the probability that a paranoia-evoking event (low/high) would be triggered at the completion of a cycle. The results showed a significant main effect for the probability factor and two-way interaction effect with the cycle time factor on the number of paranoid comments participants made and their self-reported anxiety.

  1. Interaural difference values of vestibular evoked myogenic.

    Directory of Open Access Journals (Sweden)

    Marziyeh Moallemi

    2015-01-01

    Full Text Available Migraine is a neurologic disease, which often is associated with a unilateral headache. Vestibular abnormalities are common in migraine. Vestibular evoked myogenic potentials (VEMPs assess otolith function in particular functional integrity of the saccule and the inferior vestibular nerve. We used VEMP to evaluate if the migraine headache can affect VEMP asymmetry parameters. A total of 25 patients with migraine (22 females and 3 males who were diagnosed according to the criteria of IHS-1988 were enrolled in this cross-sectional study. Control group consisted of 26 healthy participants (18 female and 8 male, without neurotological symptoms and history of migraine. The short tone burst (95 dB nHL, 500 Hz was presented to ears. VEMP was recorded with surface electromyography over the contracted ipsilateral sternocleidomastoid (SCM muscle. Although current results showed that the amplitude ratio is greater in migraine patients than normal group, there was no statistical difference between two groups in mean asymmetry parameters of VEMP. Asymmetry measurements in vestibular evoked myogenic potentials probably are not indicators of unilateral deficient in saccular pathways of migraine patients.

  2. Associative learning in humans--conditioning of sensory-evoked brain activity.

    Science.gov (United States)

    Skrandies, W; Jedynak, A

    2000-01-01

    A classical conditioning paradigm was employed in two experiments performed on 35 human volunteers. In nine subjects, the presentation of Landolt rings (conditioned stimuli, CS + ) was paired with an electric stimulus (unconditioned stimuli, UCS) applied to the left median nerve. Neutral visual control stimuli were full circles (CS -) that were not paired with the UCS. The skin conductance response (SCR) was determined in a time interval of 5 s after onset of the visual stimuli, and it was measured in the acquisition and test phase. Associative learning was reflected by a SCR occurring selectively with CS +. The same experiment was repeated with another group of 26 adults while electroencephalogram (EEG) was recorded from 30 electrodes. For each subject, mean evoked potentials were computed. In 13 of the subjects, a conditioning paradigm was followed while the other subjects served as the control group (non-contingent stimulation). There were somatosensory and visual brain activity evoked by the stimuli. Conditioned components were identified by computing cross-correlation between evoked somatosensory components and the averaged EEG. In the visual evoked brain activity, three components with mean latencies of 105.4, 183.2, and 360.3 ms were analyzed. Somatosensory stimuli were followed by major components that occurred at mean latencies of 48.8, 132.5, 219.7, 294.8, and 374.2 ms latency after the shock. All components were analyzed in terms of latency, field strength, and topographic characteristics, and were compared between groups and experimental conditions. Both visual and somatosensory brain activity was significantly affected by classical conditioning. Our data illustrate how associative learning affects the topography of brain electrical activity elicited by presentation of conditioned visual stimuli.

  3. Evidence that 5-hydroxytryptamine/sub 3/ receptors mediate cytotoxic drug and radiation-evoked emesis

    Energy Technology Data Exchange (ETDEWEB)

    Miner, W.D.; Sanger, G.J.; Turner, D.H.

    1987-08-01

    The involvement of 5-hydroxytryptamine (5-HT) 5-HT/sub 3/ receptors in the mechanisms of severe emesis evoked by cytotoxic drugs or by total body irradiation have been studied in ferrets. Anti-emetic compounds tested were domperidone (a dopamine antagonist), metoclopramide (a gastric motility stimulant and dopamine antagonist at conventional doses, a 5-HT/sub 3/ receptor antagonist at higher doses) and BRL 24924 (a potent gastric motility stimulant and a 5-HT/sub 3/ receptor antagonist). Domperidone or metoclopramide prevented apomorphine-evoked emesis, whereas BRL 24924 did not. Similar doses of domperidone did not prevent emesis evoked by cis-platin or by total body irradiation, whereas metoclopramide or BRL 24924 greatly reduced or prevented these types of emesis. Metoclopramide and BRL 24924 also prevented emesis evoked by a combination of doxorubicin and cyclophosphamide. These results are discussed in terms of a fundamental role for 5-HT/sub 3/ receptors in the mechanisms mediating severely emetogenic cancer treatment therapies.

  4. Global rotation

    International Nuclear Information System (INIS)

    Rosquist, K.

    1980-01-01

    Global rotation in cosmological models is defined on an observational basis. A theorem is proved saying that, for rigid motion, the global rotation is equal to the ordinary local vorticity. The global rotation is calculated in the space-time homogeneous class III models, with Godel's model as a special case. It is shown that, with the exception of Godel's model, the rotation in these models becomes infinite for finite affine parameter values. In some directions the rotation changes sign and becomes infinite in a direction opposite to the local vorticity. The points of infinite rotation are identified as conjugate points along the null geodesics. The physical interpretation of the infinite rotation is discussed, and a comparison with the behaviour of the area distance at conjugate points is given. (author)

  5. Rotating and translating anthropomorphic head voxel models to establish an horizontal Frankfort plane for dental CBCT Monte Carlo simulations: a dose comparison study

    Science.gov (United States)

    Stratis, A.; Zhang, G.; Jacobs, R.; Bogaerts, R.; Bosmans, H.

    2016-12-01

    In order to carry out Monte Carlo (MC) dosimetry studies, voxel phantoms, modeling human anatomy, and organ-based segmentation of CT image data sets are applied to simulation frameworks. The resulting voxel phantoms preserve patient CT acquisition geometry; in the case of head voxel models built upon head CT images, the head support with which CT scanners are equipped introduces an inclination to the head, and hence to the head voxel model. In dental cone beam CT (CBCT) imaging, patients are always positioned in such a way that the Frankfort line is horizontal, implying that there is no head inclination. The orientation of the head is important, as it influences the distance of critical radiosensitive organs like the thyroid and the esophagus from the x-ray tube. This work aims to propose a procedure to adjust head voxel phantom orientation, and to investigate the impact of head inclination on organ doses in dental CBCT MC dosimetry studies. The female adult ICRP, and three in-house-built paediatric voxel phantoms were in this study. An EGSnrc MC framework was employed to simulate two commonly used protocols; a Morita Accuitomo 170 dental CBCT scanner (FOVs: 60  ×  60 mm2 and 80  ×  80 mm2, standard resolution), and a 3D Teeth protocol (FOV: 100  ×  90 mm2) in a Planmeca Promax 3D MAX scanner. Result analysis revealed large absorbed organ dose differences in radiosensitive organs between the original and the geometrically corrected voxel models of this study, ranging from  -45.6% to 39.3%. Therefore, accurate dental CBCT MC dose calculations require geometrical adjustments to be applied to head voxel models.

  6. Neuronal Rac1 Is Required for Learning-Evoked Neurogenesis

    Science.gov (United States)

    Anderson, Matthew P.; Freewoman, Julia; Cord, Branden; Babu, Harish; Brakebusch, Cord

    2013-01-01

    Hippocampus-dependent learning and memory relies on synaptic plasticity as well as network adaptations provided by the addition of adult-born neurons. We have previously shown that activity-induced intracellular signaling through the Rho family small GTPase Rac1 is necessary in forebrain projection neurons for normal synaptic plasticity in vivo, and here we show that selective loss of neuronal Rac1 also impairs the learning-evoked increase in neurogenesis in the adult mouse hippocampus. Earlier work has indicated that experience elevates the abundance of adult-born neurons in the hippocampus primarily by enhancing the survival of neurons produced just before the learning event. Loss of Rac1 in mature projection neurons did reduce learning-evoked neurogenesis but, contrary to our expectations, these effects were not mediated by altering the survival of young neurons in the hippocampus. Instead, loss of neuronal Rac1 activation selectively impaired a learning-evoked increase in the proliferation and accumulation of neural precursors generated during the learning event itself. This indicates that experience-induced alterations in neurogenesis can be mechanistically resolved into two effects: (1) the well documented but Rac1-independent signaling cascade that enhances the survival of young postmitotic neurons; and (2) a previously unrecognized Rac1-dependent signaling cascade that stimulates the proliferative production and retention of new neurons generated during learning itself. PMID:23884931

  7. Long head of biceps: from anatomy to treatment

    Directory of Open Access Journals (Sweden)

    Marco Sarmento

    2015-01-01

    Full Text Available The long head of the biceps (LHB, tendinous structure of the proximal brachial biceps, has its well-known anatomy, which contrasts with its current functional characterization. Various forms of proximal anchor and intra–articular route, important for the correct interpretation of its contribution to the pathology of the shoulder as well as the treatment methodology, are described. Knowledge of its biomechanics results mainly from cadaveric studies that contradict each other. Already the few studies in vivo indicate a depressant and stabilizing action, anterior, for the humeral head. Its pathology is rarely isolated because it is almost always correlated with rotator cuff or labrum pathology. It can be divided into 3 major groups (inflammatory, instability and traumatic and subdivided according to its location. The anterior shoulder pain is the initial symptom of pathology of LHB Its perfect characterization is dependent on the associated injuries. Clinical tests are multiple and only their combination allows better sensitivity and specificity for LHB pathology. The arthro-MRI and dynamic ultrasound are able to increase proper diagnostic of the pathology of LHB. Treatment ranges from conservative and surgical. The latter includes the repair, tenotomy and tenodesis of LHB which can be performed by open or arthroscopic methodology. The author intends to review existing literature on all aspects related to the long head of the biceps from anatomy to treatment, presenting the latest results.

  8. The vestibular implant: Frequency-dependency of the electrically evoked Vestibulo-Ocular Reflex in humans

    Directory of Open Access Journals (Sweden)

    Raymond eVan De Berg

    2015-01-01

    Full Text Available The Vestibulo-Ocular Reflex (VOR shows frequency-dependent behavior. This study investigated whether the characteristics of the electrically evoked VOR (eVOR elicited by a vestibular implant, showed the same frequency-dependency.Twelve vestibular electrodes implanted in 7 patients with bilateral vestibular hypofunction were tested. Stimuli consisted of amplitude-modulated electrical stimulation with a sinusoidal profile at frequencies of 0.5Hz, 1Hz, and 2Hz. The main characteristics of the eVOR were evaluated and compared to the natural VOR characteristics measured in a group of age-matched healthy volunteers who were subjected to horizontal whole body rotations with equivalent sinusoidal velocity profiles at the same frequencies.A strong and significant effect of frequency was observed in the total peak eye velocity of the eVOR. This effect was similar to that observed in the natural VOR. Other characteristics of the (eVOR (angle, habituation-index, and asymmetry showed no significant frequency-dependent effect. In conclusion, this study demonstrates that, at least at the specific (limited frequency range tested, responses elicited by a vestibular implant closely mimic the frequency-dependency of the normal vestibular system.

  9. Opioid-Induced Nausea Involves a Vestibular Problem Preventable by Head-Rest.

    Directory of Open Access Journals (Sweden)

    Nadine Lehnen

    Full Text Available Opioids are indispensable for pain treatment but may cause serious nausea and vomiting. The mechanism leading to these complications is not clear. We investigated whether an opioid effect on the vestibular system resulting in corrupt head motion sensation is causative and, consequently, whether head-rest prevents nausea.Thirty-six healthy men (26.6 ± 4.3 years received an opioid remifentanil infusion (45 min, 0.15 μg/kg/min. Outcome measures were the vestibulo-ocular reflex (VOR gain determined by video-head-impulse-testing, and nausea. The first experiment (n = 10 assessed outcome measures at rest and after a series of five 1-Hz forward and backward head-trunk movements during one-time remifentanil administration. The second experiment (n = 10 determined outcome measures on two days in a controlled crossover design: (1 without movement and (2 with a series of five 1-Hz forward and backward head-trunk bends 30 min after remifentanil start. Nausea was psychophysically quantified (scale from 0 to 10. The third controlled crossover experiment (n = 16 assessed nausea (1 without movement and (2 with head movement; isolated head movements consisting of the three axes of rotation (pitch, roll, yaw were imposed 20 times at a frequency of 1 Hz in a random, unpredictable order of each of the three axes. All movements were applied manually, passively with amplitudes of about ± 45 degrees.The VOR gain decreased during remifentanil administration (p<0.001, averaging 0.92 ± 0.05 (mean ± standard deviation before, 0.60 ± 0.12 with, and 0.91 ± 0.05 after infusion. The average half-life of VOR recovery was 5.3 ± 2.4 min. 32/36 subjects had no nausea at rest (nausea scale 0.00/0.00 median/interquartile range. Head-trunk and isolated head movement triggered nausea in 64% (p<0.01 with no difference between head-trunk and isolated head movements (nausea scale 4.00/7.25 and 1.00/4.5, respectively.Remifentanil reversibly decreases VOR gain at a half

  10. The internal vertebral venous plexus prevents compression of the dural sac during atlanto-axial rotation

    Energy Technology Data Exchange (ETDEWEB)

    Reesink, E.M.; Lataster, L.M.A.; Mameren, H. van [Dept. of Anatomy/Embryology, Maastricht Univ. (Netherlands); Wilmink, J.T. [Dept. of Radiology, University Hospital Maastricht (Netherlands); Kingma, H. [Dept. of ENT, University Hospital Maastricht (Netherlands)

    2001-10-01

    Deformation of the extradural space and the possibility of impression upon the dural sac during atlanto-axial rotation are investigated. Atlanto-axial rotation leads to a reduction in the cross-sectional area of the bony spinal canal of approximately 40 %. Atlanto-axial rotation was recorded by endocanalar views from a video camera fixed inside the skull of six unembalmed cadavers. Axial thin-section T1-weighted MRI slice sets were acquired from three volunteers (mid-position and maximal left and right rotation of the head and cervical spine). The axial cross-sectional areas of the bony spinal canal, dural sac and spinal cord were measured. In two other persons post-gadolinium contrast-enhanced T1-weighted MRI volume scans with fat-suppression prepulse were acquired (mid-position and rotation) to determine venous contents of the extradural space. The 50:50 ratio between left and right extradural halves in mid-position changed to an ipsilateral:contralateral ratio of 20:80 in maximum rotation at the level just above the lateral C1-C2 joints. Directly below these joints the opposite occurred. The post-contrast studies showed an enhancing internal vertebral venous plexus (IVVP), which almost completely occupied the extradural space at the atlanto-axial level. This could not be shown in the cadaver experiments, because of absence of blood and cerebrospinal fluid (CSF) pressure. During atlanto-axial rotation blood displacement in the IVVP allows major deformations of the extradural space. This prevents dural sac impression. (orig.)

  11. Musical Brains. A study of evoked musical sensations without external auditory stimuli. Preliminary report of three cases

    International Nuclear Information System (INIS)

    Goycoolea, Marcos V; Mena, Ismael; Neubauer, Sonia G; Levy, Raquel G.; Fernandez Grez, Margarita; Berger, Claudia G

    2006-01-01

    Background: There are individuals, usually musicians, who are seemingly able to evoke musical sensations without external auditory stimuli. However, to date there is no available evidence to determine if it is feasible to have musical sensations without using external sensory receptors nor if there is a biological substrate to these sensations. Study design: Two single photon emission computerized tomography (SPECT) evaluations with [99mTc]-HMPAO were conducted in each of three female musicians. One was done under basal conditions (without evoking) and the other one while evoking these sensations. Results: In the NeuroSPECT studies of the musicians who were tested while evoking a musical composition, there was a significant increase in perfusion above the normal mean in the right and left hemispheres in Brodmann's areas 9 and 8 (frontal executive area) and in areas 40 on the left side (auditory center). However, under basal conditions there was no hyper perfusion of areas 9, 8, 39 and 40. In one case hyper perfusion was found under basal conditions in area 45, however it was less than when she was evoking. Conclusions: These findings are suggestive of a biological substrate to the process of evoking musical sensations (au)

  12. Do Magnetic Resonance Imaging Characteristics of Full-Thickness Rotator Cuff Tears Correlate With Sleep Disturbance?

    Science.gov (United States)

    Reyes, Bryan A; Hull, Brandon R; Kurth, Alexander B; Kukowski, Nathan R; Mulligan, Edward P; Khazzam, Michael S

    2017-11-01

    Many patients with rotator cuff tears suffer from nocturnal shoulder pain, resulting in sleep disturbance. To determine whether rotator cuff tear size correlated with sleep disturbance in patients with full-thickness rotator cuff tears. Cross-sectional study; Level of evidence, 3. Patients with a diagnosis of unilateral full-thickness rotator cuff tears (diagnosed via magnetic resonance imaging [MRI]) completed the Pittsburgh Sleep Quality Index (PSQI), a visual analog scale (VAS) quantifying their shoulder pain, and the American Shoulder and Elbow Surgeons (ASES) questionnaire. Shoulder MRI scans were analyzed for anterior-posterior tear size (mm), tendon retraction (mm), Goutallier grade (0-4), number of tendons involved (1-4), muscle atrophy (none, mild, moderate, or severe), and humeral head rise (present or absent). Bivariate correlations were calculated between the MRI characteristics and baseline survey results. A total of 209 patients with unilateral full-thickness rotator cuff tears were included in this study: 112 (54%) female and 97 (46%) male (mean age, 64.1 years). On average, shoulder pain had been present for 24 months. The mean PSQI score was 9.8, and the mean VAS score was 5.0. No significant correlations were found between any of the rotator cuff tear characteristics and sleep quality. Only tendon retraction had a significant correlation with pain. Although rotator cuff tears are frequently associated with nocturnal pain and sleep disruption, this study demonstrated that morphological characteristics of full-thickness rotator cuff tears, such as size and tendon retraction, do not correlate with sleep disturbance and have little to no correlation with pain levels.

  13. Aerial Rotation Effects on Vertical Jump Performance Among Highly Skilled Collegiate Soccer Players.

    Science.gov (United States)

    Barker, Leland A; Harry, John R; Dufek, Janet S; Mercer, John A

    2017-04-01

    Barker, LA, Harry, JR, Dufek, JS, and Mercer, JA. Aerial rotation effects on vertical jump performance among highly skilled collegiate soccer players. J Strength Cond Res 31(4): 932-938, 2017-In soccer matches, jumps involving rotations occur when attempting to head the ball for a shot or pass from set pieces, such as corner kicks, goal kicks, and lob passes. However, the 3-dimensional ground reaction forces used to perform rotational jumping tasks are currently unknown. Therefore, the purpose of this study was to compare bilateral, 3-dimensional, and ground reaction forces of a standard countermovement jump (CMJ0) with those of a countermovement jump with a 180° rotation (CMJ180) among Division-1 soccer players. Twenty-four participants from the soccer team of the University of Nevada performed 3 trials of CMJ0 and CMJ180. Dependent variables included jump height, downward and upward phase times, vertical (Fz) peak force and net impulse relative to mass, and medial-lateral and anterior-posterior force couple values. Statistical significance was set a priori at α = 0.05. CMJ180 reduced jump height, increased the anterior-posterior force couple in the downward and upward phases, and increased upward peak Fz (p ≤ 0.05). All other variables were not significantly different between groups (p > 0.05). However, we did recognize that downward peak Fz trended lower in the CMJ0 condition (p = 0.059), and upward net impulse trended higher in the CMJ0 condition (p = 0.071). It was concluded that jump height was reduced during the rotational jumping task, and rotation occurred primarily via AP ground reaction forces through the entire countermovement jump. Coaches and athletes may consider additional rotational jumping in their training programs to mediate performance decrements during rotational jump tasks.

  14. Nostalgia-Evoked Inspiration: Mediating Mechanisms and Motivational Implications.

    Science.gov (United States)

    Stephan, Elena; Sedikides, Constantine; Wildschut, Tim; Cheung, Wing-Yee; Routledge, Clay; Arndt, Jamie

    2015-10-01

    Six studies examined the nostalgia-inspiration link and its motivational implications. In Study 1, nostalgia proneness was positively associated with inspiration frequency and intensity. In Studies 2 and 3, the recollection of nostalgic (vs. ordinary) experiences increased both general inspiration and specific inspiration to engage in exploratory activities. In Study 4, serial mediational analyses supported a model in which nostalgia increases social connectedness, which subsequently fosters self-esteem, which then boosts inspiration. In Study 5, a rigorous evaluation of this serial mediational model (with a novel nostalgia induction controlling for positive affect) reinforced the idea that nostalgia-elicited social connectedness increases self-esteem, which then heightens inspiration. Study 6 extended the serial mediational model by demonstrating that nostalgia-evoked inspiration predicts goal pursuit (intentions to pursue an important goal). Nostalgia spawns inspiration via social connectedness and attendant self-esteem. In turn, nostalgia-evoked inspiration bolsters motivation. © 2015 by the Society for Personality and Social Psychology, Inc.

  15. Do the radial head prosthesis components fit with the anatomical structures of the proximal radioulnar joint?

    Science.gov (United States)

    Wegmann, Kilian; Hain, Moritz K; Ries, Christian; Neiss, Wolfram F; Müller, Lars P; Burkhart, Klaus J

    2015-09-01

    The fitting accuracy of radial head components has been investigated in the capitulo-radial joint, and reduced contact after prosthetic replacement of the radial head has been observed. The kinematics of the proximal radioulnar joint (PRUJ) are affected by radial head arthroplasty as well, but have not yet been investigated in this regard. The elbow joints of 60 upper extremities of formalin-fixed body donors were disarticulated to obtain a good view of the PRUJ. Each specimen was mounted on the examining table and radial head position in the native PRUJ was assessed in neutral position, full pronation, and full supination. Measurements were repeated after implantation of mono- and bi-polar prostheses. Analysis of the distribution of the joint contacts in the compartments showed significant differences after radial head replacement. In comparison to the native joint, after bipolar and monopolar radial head replacement, the physiological shift of the proximal radius was altered. The physiological shift of the joint contact of the radial head from anterior to posterior during forearm rotation that was found in the native joint in our cadaver model was not observed after prosthetic replacement. With higher conformity and physiological kinematic of radial head prostheses, possibly lower shear forces and lower contact pressures would be generated. The tested radial head prostheses do not replicate the physiological kinematics of the radial head. Further development in the prosthesis design has to be made. The meticulous reconstruction of the annular ligament seems to be of importance to increase joint contact.

  16. The relationship between age, rotator cuff integrity, and osseous microarchitecture of greater tuberosity: Where should we put anchor?

    Science.gov (United States)

    Kholinne, Erica; Lee, Hyun Joo; Kim, Sung Jung; Park, So Hyun; Jeon, In-Ho

    2018-01-01

    The aim of this study was to compare the microarchitecture of the greater tuberosity with or without rotator cuff tear and to obtain optimum location for anchor screw insertion for rotator cuff repair. Twenty-five humeral heads were harvested from 13 male cadavers of mean age 58.4 years, including 6 humeri with rotator cuff tear and 19 intact humeri. Six regions of interest (proximal, intermediate, and distal zones of the superficial and deep regions) were divided into the anterior (G1), middle (G2), and posterior (G3) areas of the greater tuberosity. Trabecular bone volume and cortical thickness were evaluated. Total trabecular bone volume was greater in subjects 50 years old but did not differ significantly in subjects with and without rotator cuff tear. Cortical thickness in both intact and torn rotator cuff groups was significantly greater in the proximal and intermediate zones than in the distal zone. Cortical thickness was related to anatomic location rather than age or cuff tear. The optimal location for anchor screw insertion during rotator cuff repair is either the proximal or intermediate region of the greater tuberosity. Age has more influence in terms of trabecular bone volume loss than rotator cuff integrity. Copyright © 2017. Production and hosting by Elsevier B.V.

  17. Counter-rotating type axial flow pump unit in turbine mode for micro grid system

    International Nuclear Information System (INIS)

    Kasahara, R; Takano, G; Komaki, K; Murakami, T; Kanemoto, T

    2012-01-01

    Traditional type pumped storage system contributes to adjust the electric power unbalance between day and night, in general. This serial research proposes the hybrid power system combined the wind power unit with the pump-turbine unit, to provide the constant output for the grid system, even at the suddenly fluctuating/turbulent wind. In the pumping mode, the pump should operate unsteadily at not only the normal but also the partial discharge. The operation may be unstable in the rising portion of the head characteristics at the lower discharge, and/or bring the cavitation at the low suction head. To simultaneously overcome both weak points, the authors have proposed a superior pump unit that is composed of counter-rotating type impellers and a peculiar motor with double rotational armatures. This paper discusses the operation at the turbine mode of the above unit. It is concluded with the numerical simulations that this type unit can be also operated acceptably at the turbine mode, because the unit works so as to coincide the angular momentum change through the front runners/impellers with that thorough the rear runners/impellers, namely to take the axial flow at not only the inlet but also the outlet without the guide vanes.

  18. Fetal MEG evoked response latency from beamformer with random field theory.

    Science.gov (United States)

    McCubbin, J; Vrba, J; Murphy, P; Temple, J; Eswaran, H; Lowery, C L; Preissl, H

    2010-01-01

    Analysis of fetal magnetoencephalographic brain recordings is restricted by low signal to noise ratio (SNR) and non-stationarity of the sources. Beamformer techniques have been applied to improve SNR of fetal evoked responses. However, until now the effect of non-stationarity was not taken into account in detail, because the detection of evoked responses is in most cases determined by averaging a large number of trials. We applied a windowing technique to improve the stationarity of the data by using short time segments recorded during a flash-evoked study. In addition, we implemented a random field theory approach for more stringent control of false-positives in the statistical parametric map of the search volume for the beamformer. The search volume was based on detailed individual fetal/maternal biometrics from ultrasound scans and fetal heart localization. Average power over a sliding window within the averaged evoked response against a randomized average background power was used as the test z-statistic. The significance threshold was set at 10% over all members of a contiguous cluster of voxels. There was at least one significant response for 62% of fetal and 95% of newborn recordings with gestational age (GA) between 28 and 45 weeks from 29 subjects. We found that the latency was either substantially unchanged or decreased with increasing GA for most subjects, with a nominal rate of about -11 ms/week. These findings support the anticipated neurophysiological development, provide validation for the beamformer model search as a methodology, and may lead to a clinical test for fetal cognitive development.

  19. Photomultiplier tube artifacts on 67Ga-citrate imaging caused by loss of correction floods due to an off-peak status of one head of a dual-head γ-camera.

    Science.gov (United States)

    Glaser, Joseph E; Song, Na; Jaini, Sridivya; Lorenzo, Ruth; Love, Charito

    2012-12-01

    γ-cameras use flood-field corrections to ensure image uniformity during clinical imaging. A loss or corruption of the correction data of one head of a dual-head camera can result in an off-peak artifactual appearance. We present our experience with the occurrence of such an incident on a (67)Ga scan. A patient was referred for a whole-body (67)Ga scan to evaluate for causes of neutropenic fever. Whole-body planar and static images of the head, chest, abdomen, pelvis, and lower extremities in multiple projections were obtained. Whole-body images showed decreased image quality on the anterior view obtained with detector 1 and an unremarkable posterior image obtained with detector 2. A problem with detector 2 was suspected, and additional static images were obtained after rotation of the detector heads. The posterior images taken with detector 1 showed photomultiplier tube outlines. The anterior images taken with detector 2 showed improved count and image quality. It was later found that the uniformity map for detector 2 had been lost and that this software malfunction led to the resulting imaging problem. When artifacts with an off-peak appearance are seen on scintigraphic images, evaluation of possible causes should include not only isotope window settings but also an incorrect or corrupted uniformity map.

  20. A technique for accurate planning of stereotactic brain implants prior to head ring fixation

    International Nuclear Information System (INIS)

    Ulin, Kenneth; Bornstein, Linda E.; Ling, Marilyn N.; Saris, Stephen; Wu, Julian K.; Curran, Bruce H.; Wazer, David E.

    1997-01-01

    Purpose: A two-step procedure is described for accurate planning of stereotactic brain implants prior to head-ring fixation. Methods and Materials: Approximately 2 weeks prior to implant a CT scan without the head ring is performed for treatment-planning purposes. An entry point and a reference point, both marked with barium and later tattooed, facilitate planning and permit correlation of the images with a later CT scan. A plan is generated using a conventional treatment-planning system to determine the number and activity of I-125 seeds required and the position of each catheter. I-125 seed anisotropy is taken into account by means of a modification to the treatment planning program. On the day of the implant a second CT scan is performed with the head ring affixed to the skull and with the same points marked as in the previous scan. The planned catheter coordinates are then mapped into the coordinate system of the second CT scan by means of a manual translational correction and a computer-calculated rotational correction derived from the reference point coordinates in the two scans. Results: The rotational correction algorithm was verified experimentally in a Rando phantom before it was used clinically. For analysis of the results with individual patients a third CT scan is performed 1 day following the implant and is used for calculating the final dosimetry. Conclusion: The technique that is described has two important advantages: 1) the number and activity of seeds required can be accurately determined in advance; and 2) sufficient time is allowed to derive the best possible plan

  1. Epidemiology, natural history, and indications for treatment of rotator cuff tears.

    Science.gov (United States)

    Tashjian, Robert Z

    2012-10-01

    years old) with chronic tears; in patients with irreparable rotator cuff tears with irreversible changes, including significant atrophy and fatty infiltration, humeral head migration, and arthritis; in patients of any age with small (tears; or in patients without a full-thickness tear. Early surgical treatment can be considered in significant (>1 cm-1.5 cm) acute tears or young patients with full-thickness tears who have a significant risk for the development of irreparable rotator cuff changes. Copyright © 2012. Published by Elsevier Inc.

  2. Interactions of MK-801 with glutamate-, glutamine- and methamphetamine-evoked release of [3H]dopamine from striatal slices

    International Nuclear Information System (INIS)

    Bowyer, J.F.; Scallet, A.C.; Holson, R.R.; Lipe, G.W.; Slikker, W. Jr.; Ali, S.F.

    1991-01-01

    The interactions of MK-801 [(+)-5-methyl-10,11-dihydro-5H-dibenzo[a,d] cyclohepten-5,10-imine], glutamate and glutamine with methamphetamine (METH)-evoked release of [ 3 H]dopamine were assessed in vitro to determine whether MK-801 inhibition of METH neurotoxicity might be mediated presynaptically, and to evaluate the effects of glutamatergic stimulation on METH-evoked dopamine release. MK-801 inhibition of glutamate- or METH-evoked dopamine release might reduce synaptic dopamine levels during METH exposure and decrease the formation of 6-hydroxydopamine or other related neurotoxins. Without Mg 2+ present, 40 microM and 1 mM glutamate evoked a N-methyl-D-aspartate receptor-mediated [ 3 H]dopamine and [ 3 H]metabolite (tritium) release of 3 to 6 and 12 to 16% of total tritium stores, respectively, from striatal slices. With 1.50 mM Mg 2+ present, 10 mM glutamate alone or in combination with the dopamine uptake blocker nomifensine released only 2.1 or 4.2%, respectively, of total tritium stores, and release was only partially dependent on N-methyl-D-aspartate-type glutamate receptors. With or without 1.50 mM Mg 2+ present, 0.5 or 5 microM METH evoked a substantial release of tritium (5-8 or 12-21% of total stores, respectively). METH-evoked dopamine release was not affected by 5 microM MK-801 but METH-evoked release was additive with glutamate-evoked release. Without Mg 2+ present, 1 mM glutamine increased glutamate release and induced the release of [ 3 H]dopamine and metabolites. Both 0.5 and 5 microM METH also increased tritium release with 1 mM glutamine present. When striatal slices were exposed to 5 microM METH this glutamine-evoked release of glutamate was increased more than 50%

  3. Influence of detomidine and buprenorphine on motor-evoked potentials in horses.

    Science.gov (United States)

    Nollet, H; Van Ham, L; Gasthuys, F; Dewulf, J; Vanderstraeten, G; Deprez, P

    2003-04-26

    Horses need to be sedated before they are investigated by transcranial magnetic stimulation because of the mild discomfort induced by the evoked muscle contraction and the noise of stimulation. This paper describes the influence of a combination of detomidine (10 microg/kg bodyweight) and a low dose of buprenorphine (2.4 microg/kg) on the onset latency and peak-to-peak amplitude of magnetic motor-evoked potentials in normal horses. There were no significant differences between measurements of these parameters made before the horses were sedated and measurements made 10 and 30 minutes after the drugs were administered.

  4. Differential protective effects of motorcycle helmets against head injury.

    Science.gov (United States)

    Singleton, Michael D

    2017-05-19

    all types of head injury. Efforts to improve rotational acceleration management in motorcycle helmets should be considered.

  5. From Nose to Memory: The Involuntary Nature of Odor-evoked Autobiographical Memories in Alzheimer's Disease.

    Science.gov (United States)

    El Haj, Mohamad; Gandolphe, Marie Charlotte; Gallouj, Karim; Kapogiannis, Dimitrios; Antoine, Pascal

    2017-12-25

    Research suggests that odors may serve as a potent cue for autobiographical retrieval. We tested this hypothesis in Alzheimer's disease (AD) and investigated whether odor-evoked autobiographical memory is an involuntary process that shares similarities with music-evoked autobiographical memory. Participants with mild AD and controls were asked to retrieve 2 personal memories after odor exposure, after music exposure, and in an odor-and music-free condition. AD participants showed better specificity, emotional experience, mental time travel, and retrieval time after odor and music exposure than in the control condition. Similar beneficial effects of odor and music exposure were observed for autobiographical characteristics (i.e., specificity, emotional experience, and mental time travel), except for retrieval time which was more improved after odor than after music exposure. Interestingly, regression analyses suggested executive involvement in memories evoked in the control condition but not in those evoked after music or odor exposure. These findings suggest the involuntary nature of odor-evoked autobiographical memory in AD. They also suggest that olfactory cuing could serve as a useful and ecologically valid tool to stimulate autobiographical memory, at least in the mild stage of the disease. © The Author(s) 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  6. Newborn hearing screening with transient evoked otoacoustic emissions and automatic auditory brainstem response

    OpenAIRE

    Renata Mota Mamede de Carvallo; Carla Gentile Matas; Isabela de Souza Jardim

    2008-01-01

    Objective: The aim of the present investigation was to check Transient Evoked Otoacoustic Emissions and Automatic Auditory Brainstem Response tests applied together in regular nurseries and Newborn Intensive Care Units (NICU), as well as to describe and compare the results obtained in both groups. Methods: We tested 150 newborns from regular nurseries and 70 from NICU. Rresults: The newborn hearing screening results using Transient Evoked Otoacoustic Emissions and Automatic Auditory Brainstem...

  7. CFD Simulation and Optimization of Very Low Head Axial Flow Turbine Runner

    Directory of Open Access Journals (Sweden)

    Yohannis Mitiku Tobo

    2015-10-01

    Full Text Available The main objective of this work is Computational Fluid Dynamics (CFD modelling, simulation and optimization of very low head axial flow turbine runner  to be used to drive  a centrifugal pump of turbine-driven pump. The ultimate goal of the optimization is to produce a power of 1kW at head less than 1m from flowing  river to drive centrifugal pump using mechanical coupling (speed multiplier gear directly. Flow rate, blade numbers, turbine rotational speed, inlet angle are parameters used in CFD modeling,  simulation and design optimization of the turbine runner. The computed results show that power developed by a turbine runner increases with increasing flow rate. Pressure inside the turbine runner increases with flow rate but, runner efficiency increases for some flow rate and almost constant thereafter. Efficiency and power developed by a runner drops quickly if turbine speed increases due to higher pressure losses and conversion of pressure energy to kinetic energy inside the runner. Increasing blade number increases power developed but, efficiency does not increase always. Efficiency increases for some blade number and drops down due to the fact that  change in direction of the relative flow vector at the runner exit, which decreases the net rotational momentum and increases the axial flow velocity.

  8. Speech Evoked Auditory Brainstem Response in Stuttering

    Directory of Open Access Journals (Sweden)

    Ali Akbar Tahaei

    2014-01-01

    Full Text Available Auditory processing deficits have been hypothesized as an underlying mechanism for stuttering. Previous studies have demonstrated abnormal responses in subjects with persistent developmental stuttering (PDS at the higher level of the central auditory system using speech stimuli. Recently, the potential usefulness of speech evoked auditory brainstem responses in central auditory processing disorders has been emphasized. The current study used the speech evoked ABR to investigate the hypothesis that subjects with PDS have specific auditory perceptual dysfunction. Objectives. To determine whether brainstem responses to speech stimuli differ between PDS subjects and normal fluent speakers. Methods. Twenty-five subjects with PDS participated in this study. The speech-ABRs were elicited by the 5-formant synthesized syllable/da/, with duration of 40 ms. Results. There were significant group differences for the onset and offset transient peaks. Subjects with PDS had longer latencies for the onset and offset peaks relative to the control group. Conclusions. Subjects with PDS showed a deficient neural timing in the early stages of the auditory pathway consistent with temporal processing deficits and their abnormal timing may underlie to their disfluency.

  9. Visual Evoked Response in Children Subjected to Prenatal Maternal ...

    African Journals Online (AJOL)

    neural conduction, or arousal level. S. Afr. Med. J., 48 ... pression treatment in either development or IQ, whether ... children in brain function at an electrophysiological level, ..... Perry, N. W. and Childers, D. G. (1969): The Human Visual Evoked.

  10. Gender differences in rival characteristics that evoke jealousy in response to emotional versus sexual infidelity

    NARCIS (Netherlands)

    Buunk, Abraham (Bram); Dijkstra, Pieternel

    2004-01-01

    Previous research has shown that in men jealousy is evoked more by a rival's status-related characteristics than in women, whereas in women jealousy is evoked more by a rival's physical attractiveness than in men. The present study examined whether the occurrence of this gender difference depends

  11. Asymmetry of magnetic motor evoked potentials recorded in calf muscles of the dominant and non-dominant lower extremity.

    Science.gov (United States)

    Olex-Zarychta, Dorota; Koprowski, Robert; Sobota, Grzegorz; Wróbel, Zygmunt

    2009-08-07

    The aim of the study was to determine the applicability of magnetic stimulation and magnetic motor evoked potentials (MEPs) in motor asymmetry studies by obtaining quantitative and qualitative measures of efferent activity during low intensity magnetic stimulation of the dominant and non-dominant lower extremities. Magnetic stimulation of the tibial nerve in the popliteal fossa was performed in 10 healthy male right-handed and right-footed young adults. Responses were recorded from the lateral head of the gastrocnemius muscles of the right and left lower extremities. Response characteristics (duration, onset latency, amplitude) were analyzed in relation to the functional dominance of the limbs and in relation to the direction of the current in the magnetic coil by use of the Wilcoxon pair sequence test. The CCW direction of coil current was related to reduced amplitudes of recorded MEPs. Greater amplitudes of evoked potentials were recorded in the non-dominant extremity, both in the CW and CCW coil current directions, with the statistical significance of this effect (p=0.005). No differences in duration of response were found in the CW current direction, while in CCW the time of the left-side response was prolonged (p=0.01). In the non-dominant extremity longer onset latencies were recorded in both current directions, but only for the CW direction the side asymmetries showed a statistical significance of p=0.005. In the dominant extremity the stimulation correlated with stronger paresthesias, especially using the CCW direction of coil current. The results indicate that low intensity magnetic stimulation may be useful in quantitative and qualitative research into the motor asymmetry.

  12. Abdominal acupuncture reduces laser-evoked potentials in healthy subjects

    DEFF Research Database (Denmark)

    Pazzaglia, C.; Liguori, S.; Minciotti, I.

    2015-01-01

    Objective: Acupuncture is known to reduce clinical pain, although the exact mechanism is unknown. The aim of the current study was to investigate the effect of acupuncture on laser-evoked potential amplitudes and laser pain perception. Methods: In order to evaluate whether abdominal acupuncture...... is able to modify pain perception, 10 healthy subjects underwent a protocol in which laser-evoked potentials (LEPs) and laser pain perception were collected before the test (baseline), during abdominal acupuncture, and 15. min after needle removal. The same subjects also underwent a similar protocol...... in which, however, sham acupuncture without any needle penetration was used. Results: During real acupuncture, both N1 and N2/P2 amplitudes were reduced, as compared to baseline (p . < 0.01). The reduction lasted up to 15. min after needle removal. Furthermore, laser pain perception was reduced during...

  13. Rotator cuff injury: fat suppression MR image

    International Nuclear Information System (INIS)

    Won, Jong Yoon; Suh, Jin Suck; Park, Chang Yun; Lee, Yeon Hee; Kim, Yong Soo

    1994-01-01

    We performed the study prospectively to evaluate the advantage of fat suppression MR in the diagnosis of rotator cuff injury. Ten symptomatic patients were studied with both conventional T2WI and FST2WI using chemical shift technique. Each image was analyzed for the assessment of injuries, conspicuity of the lesion, the presence of effusion in subacromical bursae and joint space, and presence of humeral head injury. Arthroscopy was done in 4 patients following MRI. We could made presumptive diagnoses on FSMR as identical as on conventional MR in six cases(1 normal, 2 tendinitis, 2 partial thickness tear, 1 full thickness tear), two of them were confirmed by arthroscopic procedures. Two cases of partial thickness tear proved by arthroscopy were detected on FST2WI, whereas they were considered tendinitis on conventional T2WI. There were another 2 cases who showed tendinitis on FSMR, but normal on conventional T2WI. They, however, were not confirmed by either arthroscopy or surgical procedure. We found the FSMR were superior to conventional T2WI in the conspicuity of lesions and detection of joint effusion and abnormalities on the humeral head. We think FSMR of the shoulder could have significant diagnostic advantages over the conventional spin-echo MR imaging

  14. Rotator cuff injury: fat suppression MR image

    Energy Technology Data Exchange (ETDEWEB)

    Won, Jong Yoon; Suh, Jin Suck; Park, Chang Yun; Lee, Yeon Hee [Yonsei University College of Medicine, Seoul (Korea, Republic of); Kim, Yong Soo [Inje University College of Medicine, Busan (Korea, Republic of)

    1994-04-15

    We performed the study prospectively to evaluate the advantage of fat suppression MR in the diagnosis of rotator cuff injury. Ten symptomatic patients were studied with both conventional T2WI and FST2WI using chemical shift technique. Each image was analyzed for the assessment of injuries, conspicuity of the lesion, the presence of effusion in subacromical bursae and joint space, and presence of humeral head injury. Arthroscopy was done in 4 patients following MRI. We could made presumptive diagnoses on FSMR as identical as on conventional MR in six cases(1 normal, 2 tendinitis, 2 partial thickness tear, 1 full thickness tear), two of them were confirmed by arthroscopic procedures. Two cases of partial thickness tear proved by arthroscopy were detected on FST2WI, whereas they were considered tendinitis on conventional T2WI. There were another 2 cases who showed tendinitis on FSMR, but normal on conventional T2WI. They, however, were not confirmed by either arthroscopy or surgical procedure. We found the FSMR were superior to conventional T2WI in the conspicuity of lesions and detection of joint effusion and abnormalities on the humeral head. We think FSMR of the shoulder could have significant diagnostic advantages over the conventional spin-echo MR imaging.

  15. Absence of both auditory evoked potentials and auditory percepts dependent on timing cues.

    Science.gov (United States)

    Starr, A; McPherson, D; Patterson, J; Don, M; Luxford, W; Shannon, R; Sininger, Y; Tonakawa, L; Waring, M

    1991-06-01

    An 11-yr-old girl had an absence of sensory components of auditory evoked potentials (brainstem, middle and long-latency) to click and tone burst stimuli that she could clearly hear. Psychoacoustic tests revealed a marked impairment of those auditory perceptions dependent on temporal cues, that is, lateralization of binaural clicks, change of binaural masked threshold with changes in signal phase, binaural beats, detection of paired monaural clicks, monaural detection of a silent gap in a sound, and monaural threshold elevation for short duration tones. In contrast, auditory functions reflecting intensity or frequency discriminations (difference limens) were only minimally impaired. Pure tone audiometry showed a moderate (50 dB) bilateral hearing loss with a disproportionate severe loss of word intelligibility. Those auditory evoked potentials that were preserved included (1) cochlear microphonics reflecting hair cell activity; (2) cortical sustained potentials reflecting processing of slowly changing signals; and (3) long-latency cognitive components (P300, processing negativity) reflecting endogenous auditory cognitive processes. Both the evoked potential and perceptual deficits are attributed to changes in temporal encoding of acoustic signals perhaps occurring at the synapse between hair cell and eighth nerve dendrites. The results from this patient are discussed in relation to previously published cases with absent auditory evoked potentials and preserved hearing.

  16. Disorders of the long head of the biceps: tenotomy versus tenodesis.

    Science.gov (United States)

    Ribeiro, Fabiano Rebouças; Ursolino, André Petry Sandoval; Ramos, Vinicius Ferreira Lima; Takesian, Fernando Hovaguim; Tenor Júnior, Antonio Carlos; Costa, Miguel Pereira da

    2017-01-01

    Disorders of the long head of biceps tendon are common in clinical practice. Their causes could be degenerative, inflammatory, instability (subluxation or luxation) or traumatic. They are generally associated to other diseases of the shoulder, mainly rotator cuff injuries. Currently, there is controversy in the literature regarding the indications for surgical treatment and the choice of the best technique for each case, due to the possibility of esthetic deformity, loss of muscle strength, and residual pain. The objective of this study was to identify the indications for surgical treatment, the best surgical technique, and the advantages and disadvantages of each technique described in the orthopedic literature for the treatment of long head of biceps tendon injuries. A revision of the orthopedic medical literature on the following databases: Biblioteca Regional de Medicina (BIREME), Medline, PubMed, Cochrane Library and Google Scholar, comprising articles published in the period from 1991 to 2015.

  17. Methodologic aspects of acetylcholine-evoked relaxation of rabbit aorta

    DEFF Research Database (Denmark)

    Larsen, Kirsten Vendelbo; Nedergaard, Ove A.

    1999-01-01

    The acetylcholine-evoked relaxation of rabbit isolated thoracic aorta precontracted by phenylephrine was studied. Phenylephrine caused a steady contraction that was maintained for 6 h. In the presence of calcium disodium ethylenediaminetetraacetate (EDTA) and ascorbic acid the contraction decreased...

  18. Measures of spontaneous and movement-evoked pain are associated with disability in patients with whiplash injuries.

    Science.gov (United States)

    Mankovsky-Arnold, Tsipora; Wideman, Timothy H; Larivière, Christian; Sullivan, Michael J L

    2014-09-01

    This study examined the degree to which measures of spontaneous and movement-evoked pain accounted for shared or unique variance in functional disability associated with whiplash injury. The study also addressed the role of fear of movement as a mediator or moderator of the relation between different indices of pain and functional disability. Measures of spontaneous pain, single-point movement-evoked pain, repetition-induced summation of activity-related pain (RISP), and fear of movement and disability were obtained on a sample of 142 individuals who had sustained whiplash injuries. Participants' pain ratings, provided after lifting a weighted canister, were used as the index of single-point movement-evoked pain. RISP was computed as the increase in pain reported by participants over successive lifts of 18 weighted canisters. Measures of functional disability included physical lift tolerance and self-reported disability. Hierarchical regression analyses revealed that measures of single-point movement-evoked pain and RISP accounted for significant unique variance in self-reported disability, beyond the variance accounted for by the measure of spontaneous pain. Only RISP accounted for significant unique variance in lift tolerance. The results suggest that measures of movement-evoked pain represent a disability-relevant dimension of pain that is not captured by measures of spontaneous pain. The clinical and conceptual implications of the findings are discussed. This study examined the degree to which measures of spontaneous and movement-evoked pain accounted for shared or unique variance in functional disability associated with whiplash injury. The findings suggest that approaches to the clinical evaluation of pain would benefit from the inclusion of measures of movement-evoked pain. Copyright © 2014 American Pain Society. Published by Elsevier Inc. All rights reserved.

  19. Torque decrease during submaximal evoked contractions of the quadriceps muscle is linked not only to muscle fatigue.

    Science.gov (United States)

    Matkowski, Boris; Lepers, Romuald; Martin, Alain

    2015-05-01

    The aim of this study was to analyze the neuromuscular mechanisms involved in the torque decrease induced by submaximal electromyostimulation (EMS) of the quadriceps muscle. It was hypothesized that torque decrease after EMS would reflect the fatigability of the activated motor units (MUs), but also a reduction in the number of MUs recruited as a result of changes in axonal excitability threshold. Two experiments were performed on 20 men to analyze 1) the supramaximal twitch superimposed and evoked at rest during EMS (Experiment 1, n = 9) and 2) the twitch response and torque-frequency relation of the MUs activated by EMS (Experiment 2, n = 11). Torque loss was assessed by 15 EMS-evoked contractions (50 Hz; 6 s on/6 s off), elicited at a constant intensity that evoked 20% of the maximal voluntary contraction (MVC) torque. The same stimulation intensity delivered over the muscles was used to induce the torque-frequency relation and the single electrical pulse evoked after each EMS contraction (Experiment 2). In Experiment 1, supramaximal twitch was induced by femoral nerve stimulation. Torque decreased by ~60% during EMS-evoked contractions and by only ~18% during MVCs. This was accompanied by a rightward shift of the torque-frequency relation of MUs activated and an increase of the ratio between the superimposed and posttetanic maximal twitch evoked during EMS contraction. These findings suggest that the torque decrease observed during submaximal EMS-evoked contractions involved muscular mechanisms but also a reduction in the number of MUs recruited due to changes in axonal excitability. Copyright © 2015 the American Physiological Society.

  20. Tomographic evaluation of a dual-head positron emission tomography system

    International Nuclear Information System (INIS)

    Efthimiou, N; Maistros, S; Tripolitis, X; Panayiotakis, G; Samartzis, A; Loudos, G

    2011-01-01

    In this paper we present the performance evaluation results, in the planar and tomographic modes, of a low-cost positron emission tomography camera dedicated to small-animal imaging. The system consists of two pixelated Lu 2 SiO 5 crystals, two Hamamatsu H8500 position sensitive photomultiplier tubes, fast amplification electronics and an FPGA-USB-based read-out system. The parameters that have been studied are (i) saturation as a function of the head distance and photon acceptance angle, (ii) effect of the number of projections and half or complete head's rotation, (iii) spatial resolution as a function of the head distance, (iv) spatial resolution as a function of acceptance angle, (v) system's sensitivity as a function of these parameters and (vi) performance in small mice imaging. Image reconstruction has been carried out using open source software developed by our group (QSPECT), which is designed mainly for SPECT imaging. The results indicate that the system has a linear response for activities up to at least 2 MBq, which are typical in small-animal imaging. Best tomographic spatial resolution was measured to be ∼2 mm. The system has been found suitable for imaging of small mice both in the planar and tomographic modes

  1. Evoked responses to sinusoidally modulated sound in unanaesthetized dogs

    NARCIS (Netherlands)

    Tielen, A.M.; Kamp, A.; Lopes da Silva, F.H.; Reneau, J.P.; Storm van Leeuwen, W.

    1. 1. Responses evoked by sinusoidally amplitude-modulated sound in unanaesthetized dogs have been recorded from inferior colliculus and from auditory cortex structures by means of chronically indwelling stainless steel wire electrodes. 2. 2. Harmonic analysis of the average responses demonstrated

  2. Multi-channel motor evoked potential monitoring during anterior cervical discectomy and fusion

    Directory of Open Access Journals (Sweden)

    Dong-Gun Kim

    Full Text Available Objectives: Anterior cervical discectomy and fusion (ACDF surgery is the most common surgical procedure for the cervical spine with low complication rate. Despite the potential prognostic benefit, intraoperative neurophysiological monitoring (IONM, a method for detecting impending neurological compromise, is not routinely used in ACDF surgery. The present study aimed to identify the potential benefits of monitoring multi-channel motor evoked potentials (MEPs during ACDF surgery. Methods: We retrospectively reviewed 200 consecutive patients who received IONM with multi-channel MEPs and somatosensory evoked potentials (SSEPs. On average, 9.2 muscles per patient were evaluated under MEP monitoring. Results: The rate of MEP change during surgery in the multi-level ACDF group was significantly higher than the single-level group. Two patients from the single-level ACDF group (1.7% and four patients from the multi-level ACDF group (4.9% experienced post-operative motor deficits. Multi-channel MEPs monitoring during single and multi-level ACDF surgery demonstrated higher sensitivity, specificity, positive predictive and negative predictive value than SSEP monitoring. Conclusions: Multi-channel MEP monitoring might be beneficial for the detection of segmental injury as well as long tract injury during single- and multi-level ACDF surgery. Significance: This is first large scale study to identify the usefulness of multi-channel MEPs in monitoring ACDF surgery. Keywords: Disc disease, Somatosensory evoked potentials, Intraoperative neurophysiological monitoring, Motor evoked potentials, Anterior cervical discectomy and fusion

  3. Guanfacine potentiates the activation of prefrontal cortex evoked by warning signals.

    Science.gov (United States)

    Clerkin, Suzanne M; Schulz, Kurt P; Halperin, Jeffrey M; Newcorn, Jeffrey H; Ivanov, Iliyan; Tang, Cheuk Y; Fan, Jin

    2009-08-15

    Warning signals evoke an alert state of readiness that prepares for a rapid response by priming a thalamo-frontal-striatal network that includes the dorsolateral prefrontal cortex (DLPFC). Animal models indicate that noradrenergic input is essential for this stimulus-driven activation of DLPFC, but the precise mechanisms involved have not been determined. We tested the role that postsynaptic alpha(2A) adrenoceptors play in the activation of DLPFC evoked by warning cues using a placebo-controlled challenge with the alpha(2A) agonist guanfacine. Sixteen healthy young adults were scanned twice with event-related functional magnetic resonance imaging (fMRI), while performing a simple cued reaction time (RT) task following administration of a single dose of oral guanfacine (1 mg) and placebo in counterbalanced order. The RT task temporally segregates the neural effects of warning cues and motor responses and minimizes mnemonic demands. Warning cues produced a marked reduction in RT accompanied by significant activation in a distributed thalamo-frontal-striatal network, including bilateral DLPFC. Guanfacine selectively increased the cue-evoked activation of the left DLPFC and right anterior cerebellum, although this increase was not accompanied by further reductions in RT. The effects of guanfacine on DLPFC activation were specifically associated with the warning cue and were not seen for visual- or target-related activation. Guanfacine produced marked increases in the cue-evoked activation of DLPFC that correspond to the well-described actions of postsynaptic alpha(2) adrenoceptor stimulation. The current procedures provide an opportunity to test postsynaptic alpha(2A) adrenoceptor function in the prefrontal cortex in the pathophysiology of several psychiatric disorders.

  4. [Effects of sevoflurane and propofol on evoked potentials during neurosurgical anesthesia].

    Science.gov (United States)

    Nakagawa, Itsuo; Hidaka, Syozo; Okada, Hironori; Kubo, Takashi; Okamura, Kenta; Kato, Takahiro

    2006-06-01

    The effect of anesthetics on somatosensory evoked potential (SEP) and auditory brain stem response (ABR) has been a subject of intense reseach over the last two decades. In fact, volatile anesthetics have been repeatedly shown to decrease cortical amplitude in a dose-dependent fashion but the information regarding the effect of propofol is incomplete. The purpose of this study was to compare the effects of sevoflurane and propofol on evoked potentials during comparable depth of anesthesia guided by bispectral index (BIS). Forty four patients scheduled for neurosurgery were studied. Anesthesia was maintained with intravenous propofol using target controlled infusion (TCI). We measured the change of amplitude and latency of SEP(N20-P25), ABR (V wave) and visual evoked potential (VEP: P100) at three sets of sevoflurane (0%, 1%, 2%) or propofol concentrations (effect site concentration of 1.5, 2.0, 3.0 microug x ml(-1)). BIS monitor was used to measure relative depth of hypnosis. With increasing concentrations of sevoflurane (0, 1% and 2%), SEP showed dose-related reduction in its amplitude, ABR produced less marked changes and VEP showed a significant reduction at 1%. VEP at the propofol concentration of 3.0 microg x ml(-1) was decreased significantly compared with the amplitude at 1.5 microg x ml(-1) concentration. No significant change was observed with SEP and ABR during the change of propofol dosages. BIS values were almost the same with each anesthetics. VEP was most strongly affected with anesthetics, and ABR showed less marked influence of sevoflurane and propofol. Propofol based TIVA technique would induce less change in evoked potentials than sevoflurane.

  5. Pupil constriction evoked in vitro by stimulation of the oculomotor nerve in the turtle (Trachemys scripta elegans).

    Science.gov (United States)

    Dearworth, James R; Brenner, J E; Blaum, J F; Littlefield, T E; Fink, D A; Romano, J M; Jones, M S

    2009-01-01

    The pond turtle (Trachemys scripta elegans) exhibits a notably sluggish pupillary light reflex (PLR), with pupil constriction developing over several minutes following light onset. In the present study, we examined the dynamics of the efferent branch of the reflex in vitro using preparations consisting of either the isolated head or the enucleated eye. Stimulation of the oculomotor nerve (nIII) using 100-Hz current trains resulted in a maximal pupil constriction of 17.4% compared to 27.1% observed in the intact animal in response to light. When current amplitude was systematically increased from 1 to 400 microA, mean response latency decreased from 64 to 45 ms, but this change was not statistically significant. Hill equations fitted to these responses indicated a current threshold of 3.8 microA. Stimulation using single pulses evoked a smaller constriction (3.8%) with response latencies and threshold similar to that obtained using train stimulation. The response evoked by postganglionic stimulation of the ciliary nerve using 100-Hz trains was largely indistinguishable from that of train stimulation of nIII. However, application of single-pulse stimulation postganglionically resulted in smaller pupil constriction at all current levels relative to that of nIII stimulation, suggesting that there is amplification of efferent drive at the ganglion. Time constants for constrictions ranged from 88 to 154 ms with relaxations occurring more slowly at 174-361 ms. These values for timing from in vitro are much faster than the time constant 1.66 min obtained for the light response in the intact animal. The rapid dynamics of pupil constriction observed here suggest that the slow PLR of the turtle observed in vivo is not due to limitations of the efferent pathway. Rather, the sluggish response probably results from photoreceptive mechanisms or central processing.

  6. [Treatment of adult congenital muscular torticollis by multiple sternocleidomastoid head amputation].

    Science.gov (United States)

    Fu, Ronggang; Yin, Xiuqing; Yu, Rong

    2012-02-01

    To investigate the therapeutic method and effectiveness of multiple sternocleidomastoid head amputation for adult congenital muscular torticollis. Between March 2009 and February 2011, 19 patients with congenital muscular torticollis were treated with multiple sternocleidomastoid head amputation. There were 13 males and 6 females, aged 16-32 years (mean, 23.5 years). The X-ray films showed that 12 cases were accompanied with some extent cervical lateral bending and wedge change. Ten patients were with ipsilateral facial bradygenesis. Four patients had received single sternocleidomastoid head amputation. All of the 19 patients were treated with multiple sternocleidomastoid head amputation, then plaster support and neck collar were used after operation for 3-6 months. The wounds of all the 19 patients healed primarily, without infection or hematoma. Sixteen patients were followed up 5 months to 2 years (mean, 8 months). The head and neck malformations were ameliorated significantly. The effectiveness was assessed 2 weeks later, in 7 patients without cervical vertebral malformation results were excellent; in 12 patients with cervical vertebral malformation, the results were excellent in 1 case, good in 7 cases, and fair in 4 cases. The length between mastoid process and sternoclavicular joints was elongated (1.88 +/- 0.30) cm significantly after operation in patients without cervical vertebral malformation (t = 6.24, P = 0.00), showing no significant difference when compared with normal value (t = 1.87, P = 0.11); the length was elongated (3.38 +/- 0.30) cm significantly (t = 11.37, P = 0.00) after operation in patients with cervical vertebral malformation, but it was significant shorter than normal value (t = 12.19, P = 0.00). Multiple sternocleidomastoid head amputation is a safe and effective method for adult congenital muscular torticollis, which can improve the neck rotation function.

  7. An Attitude Heading and Reference System For Marine Satellite Tracking Antenna

    DEFF Research Database (Denmark)

    Wang, Yunlong; Soltani, Mohsen; Hussain, Dil muhammed Akbar

    2017-01-01

    One of the most challenging problems for marine satellite tracking antennas (MSTAs) is to estimate the antenna attitude, which is affected by the ship motion, especially the ship vibration and rotational motions caused by ocean waves. To overcome this problem, an attitude heading and reference...... conditions, an attitude estimator based on virtual horizontal reference is introduced for situations of accelerometer malfunction, where the ship is suffering from wave shocks in high sea states. The performance of the designed AHRS for MSTA is assessed through hardware experiments using a Stewart platform...

  8. Cortical modulation of short-latency TMS-evoked potentials

    Directory of Open Access Journals (Sweden)

    Domenica eVeniero

    2013-01-01

    Full Text Available Transcranial magnetic stimulation - electroencephalogram (TMS-EEG co-registration offers the opportunity to test reactivity of brain areas across distinct conditions through TMS-evoked potentials (TEPs. Several TEPs have been described, their functional meaning being largely unknown. In particular, short-latency potentials peaking at 5 (P5 and 8 (N8 ms after the TMS pulse have been recently described, but because of their huge amplitude, the problem of whether their origin is cortical or not has been opened. To gain information about these components, we employed a protocol that modulates primary motor cortex excitability (MI through an exclusively cortical phenomena: low frequency stimulation of premotor area (PMC. TMS was applied simultaneously with EEG recording from 70 electrodes. Amplitude of TEPs evoked by 200 single-pulses TMS delivered over MI at 110% of resting motor threshold was measured before and after applying 900 TMS conditioning stimuli to left premotor cortex with 1 Hz repetition rate. Single subject analyses showed reduction in TEPs amplitude after PMC conditioning in a sample of participants and increase in TEPs amplitude in two subjects. No effects were found on corticospinal excitability as recorded by motor evoked potentials (MEPs. Furthermore, correlation analysis showed an inverse relation between the effects of the conditioning protocol on P5-N8 complex amplitude and MEPs amplitude. Because the effects of the used protocol have been ascribed to a cortical interaction between premotor area and MI, we suggest that despite the sign of P5-N8 amplitude modulation is not consistent across participant, this modulation could indicate, at least in part, their cortical origin. We conclude that with an accurate experimental procedure early-latency components can be used to evaluate the reactivity of the stimulated cortex.

  9. Single-sweep spectral analysis of contact heat evoked potentials

    DEFF Research Database (Denmark)

    Hansen, Tine M; Graversen, Carina; Frøkjaer, Jens B

    2015-01-01

    AIMS: The cortical response to nociceptive thermal stimuli recorded as contact heat evoked potentials (CHEPs) may be altered by morphine. However, previous studies have averaged CHEPs over multiple stimuli, which are confounded by jitter between sweeps. Thus, the aim was to assess single-sweep ch......AIMS: The cortical response to nociceptive thermal stimuli recorded as contact heat evoked potentials (CHEPs) may be altered by morphine. However, previous studies have averaged CHEPs over multiple stimuli, which are confounded by jitter between sweeps. Thus, the aim was to assess single...... by 13% (P = 0.04) and 9% (P = 0.007), while the beta and gamma bands were increased by 10% (P = 0.006) and 24% (P = 0.04). CONCLUSION: The decreases in the delta and theta band are suggested to represent a decrease in the pain specific morphology of the CHEPs, which indicates a diminished pain response...

  10. The roles of superficial amygdala and auditory cortex in music-evoked fear and joy.

    Science.gov (United States)

    Koelsch, Stefan; Skouras, Stavros; Fritz, Thomas; Herrera, Perfecto; Bonhage, Corinna; Küssner, Mats B; Jacobs, Arthur M

    2013-11-01

    This study investigates neural correlates of music-evoked fear and joy with fMRI. Studies on neural correlates of music-evoked fear are scant, and there are only a few studies on neural correlates of joy in general. Eighteen individuals listened to excerpts of fear-evoking, joy-evoking, as well as neutral music and rated their own emotional state in terms of valence, arousal, fear, and joy. Results show that BOLD signal intensity increased during joy, and decreased during fear (compared to the neutral condition) in bilateral auditory cortex (AC) and bilateral superficial amygdala (SF). In the right primary somatosensory cortex (area 3b) BOLD signals increased during exposure to fear-evoking music. While emotion-specific activity in AC increased with increasing duration of each trial, SF responded phasically in the beginning of the stimulus, and then SF activity declined. Psychophysiological Interaction (PPI) analysis revealed extensive emotion-specific functional connectivity of AC with insula, cingulate cortex, as well as with visual, and parietal attentional structures. These findings show that the auditory cortex functions as a central hub of an affective-attentional network that is more extensive than previously believed. PPI analyses also showed functional connectivity of SF with AC during the joy condition, taken to reflect that SF is sensitive to social signals with positive valence. During fear music, SF showed functional connectivity with visual cortex and area 7 of the superior parietal lobule, taken to reflect increased visual alertness and an involuntary shift of attention during the perception of auditory signals of danger. Copyright © 2013 Elsevier Inc. All rights reserved.

  11. The effect of digital signage on shoppers’ behavior: the role of the evoked experience

    OpenAIRE

    Dennis, Charles; Brakus, J. Joško; Gupta, Suraksha; Alamanos, Eleftherios

    2014-01-01

    This paper investigates the role of digital signage as experience provider in retail spaces. The findings of a survey-based field experiment demonstrate that digital signage content high on sensory cues evokes affective experience and strengthens customers' experiential processing route. In contrast, digital signage messages high on “features and benefits” information evoke intellectual experience and strengthen customers' deliberative processing route. The affective experience is more strong...

  12. The head tracks and gaze predicts: how the world's best batters hit a ball.

    Directory of Open Access Journals (Sweden)

    David L Mann

    Full Text Available Hitters in fast ball-sports do not align their gaze with the ball throughout ball-flight; rather, they use predictive eye movement strategies that contribute towards their level of interceptive skill. Existing studies claim that (i baseball and cricket batters cannot track the ball because it moves too quickly to be tracked by the eyes, and that consequently (ii batters do not - and possibly cannot - watch the ball at the moment they hit it. However, to date no studies have examined the gaze of truly elite batters. We examined the eye and head movements of two of the world's best cricket batters and found both claims do not apply to these batters. Remarkably, the batters coupled the rotation of their head to the movement of the ball, ensuring the ball remained in a consistent direction relative to their head. To this end, the ball could be followed if the batters simply moved their head and kept their eyes still. Instead of doing so, we show the elite batters used distinctive eye movement strategies, usually relying on two predictive saccades to anticipate (i the location of ball-bounce, and (ii the location of bat-ball contact, ensuring they could direct their gaze towards the ball as they hit it. These specific head and eye movement strategies play important functional roles in contributing towards interceptive expertise.

  13. Perceptual learning of acoustic noise generates memory-evoked potentials.

    Science.gov (United States)

    Andrillon, Thomas; Kouider, Sid; Agus, Trevor; Pressnitzer, Daniel

    2015-11-02

    Experience continuously imprints on the brain at all stages of life. The traces it leaves behind can produce perceptual learning [1], which drives adaptive behavior to previously encountered stimuli. Recently, it has been shown that even random noise, a type of sound devoid of acoustic structure, can trigger fast and robust perceptual learning after repeated exposure [2]. Here, by combining psychophysics, electroencephalography (EEG), and modeling, we show that the perceptual learning of noise is associated with evoked potentials, without any salient physical discontinuity or obvious acoustic landmark in the sound. Rather, the potentials appeared whenever a memory trace was observed behaviorally. Such memory-evoked potentials were characterized by early latencies and auditory topographies, consistent with a sensory origin. Furthermore, they were generated even on conditions of diverted attention. The EEG waveforms could be modeled as standard evoked responses to auditory events (N1-P2) [3], triggered by idiosyncratic perceptual features acquired through learning. Thus, we argue that the learning of noise is accompanied by the rapid formation of sharp neural selectivity to arbitrary and complex acoustic patterns, within sensory regions. Such a mechanism bridges the gap between the short-term and longer-term plasticity observed in the learning of noise [2, 4-6]. It could also be key to the processing of natural sounds within auditory cortices [7], suggesting that the neural code for sound source identification will be shaped by experience as well as by acoustics. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. A Parallel World for the World Bank: A Case Study of Urgent: Evoke, An Educational Alternate Reality Game

    Directory of Open Access Journals (Sweden)

    David I. Waddington

    2013-01-01

    Full Text Available In 2010, the World Bank launched Urgent: Evoke, an alternate reality game. Conceived in response to the demands of African universities, the game was designed to promote the World Bank Institute’s vision of positive global change through social innovation, and made substantial use of Web 2.0 tools such as blogs, personal profiles, and social networks. This article offers a case study of Urgent: Evoke, divided into four sections: first, the potential to use video games as citizenship education tools is discussed; second, the unique game genre (alternate reality games into which Evoke falls is explained and some possible uses of this genre in higher education are examined; third, the functioning of the Evoke game world is explained; and fourth, the results of the Evoke educational project are assessed. The case study concludes with some commentary on Evoke’s ideological message, which those less sympathetic to capitalism may view as problematic.

  15. Rotating sensor technology for the inspection of steam generator tubing

    International Nuclear Information System (INIS)

    Glass, S.W.; Richards, T.A.

    1986-01-01

    A high-resolution profilometry system, has been developed to assess the dimensional condition of steam generator tubes and rapidly produce the data to evaluate the potential for developing in-service leaks. The probe has an electromechanical sensor in a rotating head. This technique has been demonstrated in the field at four U.S. plants and one plant owned by Electricite de France. The Indian Point-2 plant of Consolidated Edison has twice used this technology to save tubes that would have been plugged with the go-gauge criterion and identifying other high-risk candidates for plugging that might otherwise not have been removed from service. As an extension of the PROFIL-360 technology, a rotating eddy current system (EDDY-360) has also been developed. The system provides improved sensitivity, resolution, and characterization of small-volume flaws and complete circumferential coverage as compared to conventional (bobbin and 8 x 1) eddy current techniques. Enhanced eddy current data processing provides on-line data analysis and real-time imaging of detected flaws. (author)

  16. On Averaging Rotations

    DEFF Research Database (Denmark)

    Gramkow, Claus

    1999-01-01

    In this article two common approaches to averaging rotations are compared to a more advanced approach based on a Riemannian metric. Very offten the barycenter of the quaternions or matrices that represent the rotations are used as an estimate of the mean. These methods neglect that rotations belo...... approximations to the Riemannian metric, and that the subsequent corrections are inherient in the least squares estimation. Keywords: averaging rotations, Riemannian metric, matrix, quaternion......In this article two common approaches to averaging rotations are compared to a more advanced approach based on a Riemannian metric. Very offten the barycenter of the quaternions or matrices that represent the rotations are used as an estimate of the mean. These methods neglect that rotations belong...

  17. Head direction cell activity in mice: robust directional signal depends on intact otolith organs

    Science.gov (United States)

    Yoder, Ryan M.; Taube, Jeffrey S.

    2009-01-01

    The head direction (HD) cell signal is a representation of an animal's perceived directional heading with respect to its environment. This signal appears to originate in the vestibular system, which includes the semicircular canals and otolith organs. Preliminary studies indicate the semicircular canals provide a necessary component of the HD signal, but involvement of otolithic information in the HD signal has not been tested. The present study was designed to determine the otolithic contribution to the HD signal, as well as to compare HD cell activity of mice to that of rats. HD cell activity in the anterodorsal thalamus was assessed in wild-type C57BL/6J and otoconia-deficient tilted mice during locomotion within a cylinder containing a prominent visual landmark. HD cell firing properties in C57BL/6J mice were generally similar to those in rats. However, in C57BL/6J mice, landmark rotation failed to demonstrate dominant control of the HD signal in 36% of the sessions. In darkness, directional firing became unstable during 42% of the sessions, but landmark control was not associated with HD signal stability in darkness. HD cells were identified in tilted mice, but directional firing properties were not as robust as those of C57BL/6J mice. Most HD cells in tilted mice were controlled by landmark rotation, but showed substantial signal degradation across trials. These results support current models that suggest otolithic information is involved in the perception of directional heading. Furthermore, compared to rats, the HD signal in mice appears to be less reliably anchored to prominent environmental cues. PMID:19176815

  18. Dynamic properties of sensory stimulation evoked responses in mouse cerebellar granule cell layer and molecular layer.

    Science.gov (United States)

    Bing, Yan-Hua; Zhang, Guang-Jian; Sun, Lei; Chu, Chun-Ping; Qiu, De-Lai

    2015-01-12

    Sensory information coming from climbing fiber and mossy fiber-granule cell pathways, generates motor-related outputs according to internal rules of integration and computation in the cerebellar cortex. However, the dynamic properties of sensory information processing in mouse cerebellar cortex are less understood. Here, we studied the dynamic properties of sensory stimulation-evoked responses in the cerebellar granule cell layer (GCL) and molecular layer (ML) by electrophysiological recordings method. Our data showed that air-puff stimulation (5-10 ms in duration) of the ipsilateral whisker pad evoked single-peak responses in the GCL and ML; whereas a duration of stimulation ≥30 ms in GCL and ≥60 ms in ML, evoked double-peak responses that corresponded with stimulation-on and -off responses via mossy fiber pathway. The highest frequency of stimulation train for evoking GCL responses was 33 Hz. In contrast, the highest frequency of stimulation train for evoking ML responses was 4 Hz. These results indicate that the cerebellar granule cells transfer the high-fidelity sensory information from mossy fibers, which is cut-off by molecular layer interneurons (MLIs). Our results suggest that the MLIs network acts as a low-pass filter during the processing of high-frequency sensory information. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  19. Crystallization of the C-terminal head domain of the avian adenovirus CELO long fibre

    Energy Technology Data Exchange (ETDEWEB)

    Guardado Calvo, Pablo [Departamento de Bioquímica y Biología Molecular, Facultad de Farmacia, Universidad de Santiago de Compostela, Campus Sur, E-15782 Santiago de Compostela (Spain); Llamas-Saiz, Antonio L. [Unidad de Difracción de Rayos X, Laboratorio Integral de Dinámica y Estructura de Biomoléculas José R. Carracido, Edificio CACTUS, Universidad de Santiago de Compostela, Campus Sur, E-15782 Santiago de Compostela (Spain); Langlois, Patrick [Agence Francaise de Securité Sanitaire des Aliments, Unité Génétique Virale et Biosecurité, Site Les Croix, BP 53, F-22440 Ploufragan (France); Raaij, Mark J. van, E-mail: vanraaij@usc.es [Departamento de Bioquímica y Biología Molecular, Facultad de Farmacia, Universidad de Santiago de Compostela, Campus Sur, E-15782 Santiago de Compostela (Spain); Unidad de Difracción de Rayos X, Laboratorio Integral de Dinámica y Estructura de Biomoléculas José R. Carracido, Edificio CACTUS, Universidad de Santiago de Compostela, Campus Sur, E-15782 Santiago de Compostela (Spain)

    2006-05-01

    Avian adenovirus long-fibre head trimers were expressed, purified and crystallized. The crystals belong to space group C2 (unit-cell parameters a = 216.5, b = 59.2, c = 57.5 Å, β = 101.3°). A complete highly redundant data set was collected to 2.2 Å resolution at 100 K using a rotating-anode X-ray source. Avian adenovirus CELO contains two different fibres: fibre 1, the long fibre, and fibre 2, the short fibre. The short fibre is responsible for binding to an unknown avian receptor and is essential for infection of birds. The long fibre is not essential, but is known to bind the coxsackievirus and adenovirus receptor protein. Both trimeric fibres are attached to the same penton base, of which each icosahedral virus contains 12 copies. The short fibre extends straight outwards, while the long fibre emerges at an angle. The carboxy-terminal amino acids 579–793 of the avian adenovirus long fibre have been expressed with an amino-terminal hexahistidine tag and the expressed trimeric protein has been purified by nickel-affinity chromatography and crystallized. Crystals were grown at low pH using PEG 10 000 as precipitant and belonged to space group C2. The crystals diffracted rotating-anode Cu Kα radiation to at least 1.9 Å resolution and a complete data set was collected from a single crystal to 2.2 Å resolution. Unit-cell parameters were a = 216.5, b = 59.2, c = 57.5 Å, β = 101.3°, suggesting one trimer per asymmetric unit and a solvent content of 46%. The long fibre head does not have significant sequence homology to any other protein of known structure and molecular-replacement attempts with known fibre-head structures were unsuccessful. However, a map calculated using SIRAS phasing shows a clear trimer with a shape similar to known adenovirus fibre-head structures. Structure solution is in progress.

  20. Football Players' Head-Impact Exposure After Limiting of Full-Contact Practices.

    Science.gov (United States)

    Broglio, Steven P; Williams, Richelle M; O'Connor, Kathryn L; Goldstick, Jason

    2016-07-01

    Sporting organizations limit full-contact football practices to reduce concussion risk and based on speculation that repeated head impacts may result in long-term neurodegeneration. To directly compare head-impact exposure in high school football players before and after a statewide restriction on full-contact practices. Cross-sectional study. High school football field. Participants were varsity football athletes from a single high school. Before the rule change, 26 athletes (age = 16.2 ± 0.8 years, height = 179.6 ± 6.4 cm, weight = 81.9 ± 13.1 kg) participated. After the rule change, 24 athletes (age = 15.9 ± 0.8 years, height = 178.3 ± 6.5 cm, weight = 76.2 ± 11.6 kg) participated. Nine athletes participated in both years of the investigation. Head-impact exposure was monitored using the Head Impact Telemetry System while the athletes participated in football games and practices in the seasons before and after the rule change. Head-impact frequency, location, and magnitude (ie, linear acceleration, rotational acceleration, and Head Impact Telemetry severity profile [HITsp], respectively) were measured. A total of 15 398 impacts (592 impacts per player per season) were captured before the rule change and 8269 impacts (345 impacts per player per season) after the change. An average 42% decline in impact exposure occurred across all players, with practice-exposure declines occurring among linemen (46% decline); receivers, cornerbacks, and safeties (41% decline); and tight ends, running backs (including fullbacks), and linebackers (39% decline). Impact magnitudes remained largely unchanged between the years. A rule change limiting full-contact high school football practices appears to have been effective in reducing head-impact exposure across all players, with the largest reduction occurring among linemen. This finding is likely associated with the rule modification, particularly because the coaching staff and offensive scheme remained consistent, yet how

  1. A comparison of auditory evoked potentials to acoustic beats and to binaural beats

    OpenAIRE

    Pratt, H; Starr, A; Michalewski, HJ; Dimitrijevic, A; Bleich, N; Mittelman, N

    2010-01-01

    The purpose of this study was to compare cortical brain responses evoked by amplitude modulated acoustic beats of 3 and 6 Hz in tones of 250 and 1000 Hz with those evoked by their binaural beats counterparts in unmodulated tones to indicate whether the cortical processes involved differ. Event-related potentials (ERPs) were recorded to 3- and 6-Hz acoustic and binaural beats in 2000 ms duration 250 and 1000 Hz tones presented with approximately 1 s intervals. Latency, amplitude and source cur...

  2. The BUK-GPK suspended drilling equipment for the GPK heading machine

    Energy Technology Data Exchange (ETDEWEB)

    1982-11-01

    The BUK-GPK system developed by PechorNIIproekt is used for borehole drilling in rocks with compression strength to 12 degrees on the Protod'yakonov scale. The BUK-GPK is used for drilling boreholes for roof bolts in development workings driven by heading machines under difficult conditions. The GPK heading machine with the BUK-GPK drill is 10 m long, 2.1 m high and 2.1 m wide. A borehole is up to 50 mm in diameter, rotating speed ranges from 170 to 315 rpm. Drillings are removed from a boreholes by flushing using water. The system is equipped with remote control. The BUK-GPK system was tested at the Pechora basin during mine drivage in a coal seam from 1.4 to 1.5 m thick. The BUK-GPK was reliable. It permitted labor productivity and occupational safety during during mine drivage to be increased. Commercial production of the BUK-GPK drill is recommended. (In Russian)

  3. On the vertigo due to static magnetic fields.

    Directory of Open Access Journals (Sweden)

    Omar S Mian

    Full Text Available Vertigo is sometimes experienced in and around MRI scanners. Mechanisms involving stimulation of the vestibular system by movement in magnetic fields or magnetic field spatial gradients have been proposed. However, it was recently shown that vestibular-dependent ocular nystagmus is evoked when stationary in homogenous static magnetic fields. The proposed mechanism involves Lorentz forces acting on endolymph to deflect semicircular canal (SCC cupulae. To investigate whether vertigo arises from a similar mechanism we recorded qualitative and quantitative aspects of vertigo and 2D eye movements from supine healthy adults (n = 25 deprived of vision while pushed into the 7T static field of an MRI scanner. Exposures were variable and included up to 135s stationary at 7T. Nystagmus was mainly horizontal, persisted during long-exposures with partial decline, and reversed upon withdrawal. The dominant vertiginous perception with the head facing up was rotation in the horizontal plane (85% incidence with a consistent direction across participants. With the head turned 90 degrees in yaw the perception did not transform into equivalent vertical plane rotation, indicating a context-dependency of the perception. During long exposures, illusory rotation lasted on average 50 s, including 42 s whilst stationary at 7T. Upon withdrawal, perception re-emerged and reversed, lasting on average 30 s. Onset fields for nystagmus and perception were significantly correlated (p<.05. Although perception did not persist as long as nystagmus, this is a known feature of continuous SSC stimulation. These observations, and others in the paper, are compatible with magnetic-field evoked-vertigo and nystagmus sharing a common mechanism. With this interpretation, response decay and reversal upon withdrawal from the field, are due to adaptation to continuous vestibular input. Although the study does not entirely exclude the possibility of mechanisms involving transient

  4. Open repair for massive rotator cuff tear with a modified transosseous-equivalent procedure. Preliminary results at short-term follow-up

    International Nuclear Information System (INIS)

    Yamaguchi, Hiroshi; Kanaya, Fuminori; Suenaga, Naoki; Oizumi, Naomi; Hosokawa, Yoshihiro

    2011-01-01

    Many surgical procedures have been reported for rotator cuff tears. We adopted the modified transosseous-equivalent procedure, also termed ''surface-holding repair with transosseous sutures,'' and demonstrated that this procedure has a biomechanical advantage regarding the concentration of stress on the tendon stump. This study aimed to evaluate the clinical and structural outcomes of this technique, which has been demonstrated by postoperative magnetic resonance imaging (MRI) to produce high intact rates. Twenty-nine massive rotator cuff tears involving at least two tendons were treated by open repair using this procedure. Twenty-four patients were evaluated at an average of 43.2 months (range 24-71) postoperatively (the follow-up rate was 83.8%). The pre- and postoperative clinical outcomes were examined using the scoring system of the Japanese Orthopedic Association (JOA score). In an A-P radiograph, the presence of osteoarthritis (OA) of the glenohumeral joint and upward migration of the humeral head were compared pre- and postoperatively. The repair integrity of the cuff tendon was evaluated by applying Sugaya's classification to the postoperative MRIs. The JOA score improved from 42.8 points preoperatively to 89.3 points at final follow-up. Radiographic examination showed that OA progressed in 16.7% and upward migration of the humeral head progressed in 20.8%. Postoperative MRI scans revealed 14 shoulders with type 1 repair based on Sugaya's classification, 4 shoulders with type 2, 4 shoulders with type 3, 2 shoulders with type 4, and no shoulders with a type 5 repair. Although osteoarthritis of the glenohumeral joint and upward migration of the humeral head had both progressed postoperatively in some cases, postoperative MRI scans revealed that 91.7% of the repairs resulted in a continuous rotator cuff. Therefore, this technique produces a high healing rate. (author)

  5. Ultrasound measurement of rotator cuff thickness and acromio-humeral distance in the diagnosis of subacromial impingement syndrome of the shoulder.

    Science.gov (United States)

    Cholewinski, Jerzy J; Kusz, Damian J; Wojciechowski, Piotr; Cielinski, Lukasz S; Zoladz, Miroslaw P

    2008-04-01

    The usefulness of ultrasound measurements in the diagnosis of the subacromial impingement syndrome of the shoulder was evaluated. Fifty-seven patients with unilateral symptoms of the impingement syndrome underwent ultrasound examination of both shoulder joints, which included assessment of rotator cuff integrity, measurement of rotator cuff thickness and the distance between the infero-lateral edge of acromion and the apex of the greater tuberosity of humerus (AGT distance) in the standard ultrasonographic positions. As a control group, 36 volunteers (72 shoulders) with no history of shoulder pain were examined sonographically. Ultrasonographic assessment of humeral head elevation, measured as the AGT distance, proved to be useful in establishing the diagnosis of the subacromial impingement syndrome of the shoulder. A difference in rotator cuff thickness of more than 1.1 mm and a difference in the AGT distance of more than 2.1 mm between both shoulder joints may reflect dysfunction of rotator cuff muscles.

  6. Evoked traveling alpha waves predict visual-semantic categorization-speed

    Science.gov (United States)

    Fellinger, Robert; Gruber, Walter; Zauner, Andrea; Freunberger, Roman; Klimesch, Wolfgang

    2012-01-01

    In the present study we have tested the hypothesis that evoked traveling alpha waves are behaviorally significant. The results of a visual-semantic categorization task show that three early ERP components including the P1–N1 complex had a dominant frequency characteristic in the alpha range and behaved like traveling waves do. They exhibited a traveling direction from midline occipital to right lateral parietal sites. Phase analyses revealed that this traveling behavior of ERP components could be explained by phase-delays in the alpha but not theta and beta frequency range. Most importantly, we found that the speed of the traveling alpha wave was significantly and negatively correlated with reaction time indicating that slow traveling speed was associated with fast picture-categorization. We conclude that evoked alpha oscillations are functionally associated with early access to visual-semantic information and generate – or at least modulate – the early waveforms of the visual ERP. PMID:22100769

  7. Study of spatial resolution in three-dimensional rotational angiography

    International Nuclear Information System (INIS)

    Enoki, Takuya; Nasada, Toshiya; Matsumoto, Kazuma; Umehara, Takayoshi

    2006-01-01

    In interventional radiology (IVR) of cerebral aneurysms, it is important to understand the form and physical relationships between the cerebral aneurysm and the surrounding vessels. However, because the vessels in the head area are highly complex, it can be difficult to comprehend the structure using conventional angiography. Therefore, three-dimensional rotational angiography (3D-RA) has been used in recent years. This article discusses studies of the spatial resolution of 3D-RA. We reconstructed 3D-RA of an acrylic slit phantom (slit widths: 0.5, 0.75, 1.0, 1.5 mm) and examined spatial resolution by visual evaluation and profile curves. When the slit phantom was arranged to avoid the effect of beam hardening, the spatial resolution of 3D-RA was found to be as high as 0.75 mm. When the slit phantom was placed orthogonal to the rotational axis of the C-arm, the spatial resolution of 3D-RA was decreased because of the cone angle effect of X-rays. However, it was considered within the allowable range for clinical study. Consequently, 3D-RA is valuable in IVR. (author)

  8. Analysis of Spontaneous and Nerve-Evoked Calcium Transients in Intact Extraocular Muscles in Vitro

    Science.gov (United States)

    Feng, Cheng-Yuan; Hennig, Grant W.; Corrigan, Robert D.; Smith, Terence K.; von Bartheld, Christopher S.

    2012-01-01

    Extraocular muscles (EOMs) have unique calcium handling properties, yet little is known about the dynamics of calcium events underlying ultrafast and tonic contractions in myofibers of intact EOMs. Superior oblique EOMs of juvenile chickens were dissected with their nerve attached, maintained in oxygenated Krebs buffer, and loaded with fluo-4. Spontaneous and nerve stimulation-evoked calcium transients were recorded and, following calcium imaging, some EOMs were double-labeled with rhodamine-conjugated alpha-bungarotoxin (rhBTX) to identify EOM myofiber types. EOMs showed two main types of spontaneous calcium transients, one slow type (calcium waves with 1/2max duration of 2–12 s, velocity of 25–50 μm/s) and two fast “flash-like” types (Type 1, 30–90 ms; Type 2, 90–150 ms 1/2max duration). Single pulse nerve stimulation evoked fast calcium transients identical to the fast (Type 1) calcium transients. Calcium waves were accompanied by a local myofiber contraction that followed the calcium transient wavefront. The magnitude of calcium-wave induced myofiber contraction far exceeded those of movement induced by nerve stimulation and associated fast calcium transients. Tetrodotoxin eliminated nerve-evoked transients, but not spontaneous transients. Alpha-bungarotoxin eliminated both spontaneous and nerve-evoked fast calcium transients, but not calcium waves, and caffeine increased wave activity. Calcium waves were observed in myofibers lacking spontaneous or evoked fast transients, suggestive of multiply-innervated myofibers, and this was confirmed by double-labeling with rhBTX. We propose that the abundant spontaneous calcium transients and calcium waves with localized contractions that do not depend on innervation may contribute to intrinsic generation of tonic functions of EOMs. PMID:22579493

  9. Thermoreceptive innervation of human glabrous and hairy skin: a contact heat evoked potential analysis.

    Science.gov (United States)

    Granovsky, Yelena; Matre, Dagfinn; Sokolik, Alexander; Lorenz, Jürgen; Casey, Kenneth L

    2005-06-01

    The human palm has a lower heat detection threshold and a higher heat pain threshold than hairy skin. Neurophysiological studies of monkeys suggest that glabrous skin has fewer low threshold heat nociceptors (AMH type 2) than hairy skin. Accordingly, we used a temperature-controlled contact heat evoked potential (CHEP) stimulator to excite selectively heat receptors with C fibers or Adelta-innervated AMH type 2 receptors in humans. On the dorsal hand, 51 degrees C stimulation produced painful pinprick sensations and 41 degrees C stimuli evoked warmth. On the glabrous thenar, 41 degrees C stimulation produced mild warmth and 51 degrees C evoked strong but painless heat sensations. We used CHEP responses to estimate the conduction velocities (CV) of peripheral fibers mediating these sensations. On hairy skin, 41 degrees C stimuli evoked an ultra-late potential (mean, SD; N wave latency: 455 (118) ms) mediated by C fibers (CV by regression analysis: 1.28 m/s, N=15) whereas 51 degrees C stimuli evoked a late potential (N latency: 267 (33) ms) mediated by Adelta afferents (CV by within-subject analysis: 12.9 m/s, N=6). In contrast, thenar responses to 41 and 51 degrees C were mediated by C fibers (average N wave latencies 485 (100) and 433 (73) ms, respectively; CVs 0.95-1.35 m/s by regression analysis, N=15; average CV=1.7 (0.41) m/s calculated from distal glabrous and proximal hairy skin stimulation, N=6). The exploratory range of the human and monkey palm is enhanced by the abundance of low threshold, C-innervated heat receptors and the paucity of low threshold AMH type 2 heat nociceptors.

  10. Asteroid rotation rates

    International Nuclear Information System (INIS)

    Binzel, R.P.; Farinella, P.

    1989-01-01

    Within the last decade the data base of asteroid rotation parameters (rotation rates and lightcurve amplitudes) has become sufficiently large to identify some definite rends and properties which can help us to interpret asteroid collisional evolution. Many significant correlations are found between rotation parameters and diameter, with distinct changes occurring near 125 km. The size range, which is also the diameter above which self-gravity may become important, perhaps represents a division between surviving primordial asteroids and collisional fragments. A Maxwellian is able to fit the observed rotation rate distributions of asteroids with D>125 km, implying that their rotation rates may be determined by collisional evolution. Asteroids with D<125 km show an excess of slow rotators and their non-Maxwellian distributions suggests that their rotation rates are more strongly influenced by other processes, such as the distribution resulting from their formation in catastrophic disruption events. Other correlations observed in the data set include different mean rotation rates for C, S and M type asteroids implying that their surface spectra are indicative of bulk properties

  11. On Averaging Rotations

    DEFF Research Database (Denmark)

    Gramkow, Claus

    2001-01-01

    In this paper two common approaches to averaging rotations are compared to a more advanced approach based on a Riemannian metric. Very often the barycenter of the quaternions or matrices that represent the rotations are used as an estimate of the mean. These methods neglect that rotations belong ...... approximations to the Riemannian metric, and that the subsequent corrections are inherent in the least squares estimation.......In this paper two common approaches to averaging rotations are compared to a more advanced approach based on a Riemannian metric. Very often the barycenter of the quaternions or matrices that represent the rotations are used as an estimate of the mean. These methods neglect that rotations belong...

  12. Direct electrical stimulation of human cortex evokes high gamma activity that predicts conscious somatosensory perception

    Science.gov (United States)

    Muller, Leah; Rolston, John D.; Fox, Neal P.; Knowlton, Robert; Rao, Vikram R.; Chang, Edward F.

    2018-04-01

    Objective. Direct electrical stimulation (DES) is a clinical gold standard for human brain mapping and readily evokes conscious percepts, yet the neurophysiological changes underlying these percepts are not well understood. Approach. To determine the neural correlates of DES, we stimulated the somatosensory cortex of ten human participants at frequency-amplitude combinations that both elicited and failed to elicit conscious percepts, meanwhile recording neural activity directly surrounding the stimulation site. We then compared the neural activity of perceived trials to that of non-perceived trials. Main results. We found that stimulation evokes distributed high gamma activity, which correlates with conscious perception better than stimulation parameters themselves. Significance. Our findings suggest that high gamma activity is a reliable biomarker for perception evoked by both natural and electrical stimuli.

  13. Normalization reduces intersubject variability in cervical vestibular evoked myogenic potentials.

    Science.gov (United States)

    van Tilburg, Mark J; Herrmann, Barbara S; Guinan, John J; Rauch, Steven D

    2014-09-01

    Cervical vestibular evoked myogenic potentials are used to assess saccular and inferior vestibular nerve function. Normalization of the VEMP waveform has been proposed to reduce the variability in vestibular evoked myogenic potentials by correcting for muscle activation. In this study, we test the hypothesis that normalization of the raw cervical VEMP waveform causes a significant decrease in the intersubject variability. Prospective cohort study. Large specialty hospital, department of otolaryngology. Twenty healthy subjects were used in this study. All subjects underwent cervical vestibular evoked myogenic potential testing using short tone bursts at 250, 500, 750, and 1,000 Hz. Both intersubject and intrasubject variability was assessed. Variability between raw and normalized peak-to-peak amplitudes was compared using the coefficient of variation. Intrasubject variability was assessed using the intraclass correlation coefficient and interaural asymmetry ratio. cVEMPs were present in most ears. Highest peak-to-peak amplitudes were recorded at 750 Hz. Normalization did not alter cVEMP tuning characteristics. Normalization of the cVEMP response caused a significant reduction in intersubject variability of the peak-to-peak amplitude. No significant change was seen in the intrasubject variability. Normalization significantly reduces cVEMP intersubject variability in healthy subjects without altering cVEMP characteristics. By reducing cVEMP amplitude variation due to nonsaccular, muscle-related factors, cVEMP normalization is expected to improve the ability to distinguish between healthy and pathologic responses in the clinical application of cVEMP testing.

  14. Evoked responses of the superior olive to amplitude-modulated signals.

    Science.gov (United States)

    Andreeva, N G; Lang, T T

    1977-01-01

    Evoked potentials of some auditory centers of Rhinolophidae bats to amplitude-modulated signals were studied. A synchronization response was found in the cochlear nuclei (with respect to the fast component of the response) and in the superior olivary complex (with respect to both fast and slow components of the response) within the range of frequency modulation from 50 to 2000 Hz. In the inferior colliculus a synchronized response was recorded at modulation frequencies below 150 Hz, but in the medial geniculate bodies no such response was found. Evoked responses of the superior olivary complex were investigated in detail. The lowest frequencies of synchronization were recorded within the carrier frequency range of 15-30 and 80-86 kHz. The amplitude of the synchronized response is a function of the frequency and coefficient of modulation and also of the angle of stimulus presentation.

  15. Role played by acid-sensitive ion channels in evoking the exercise pressor reflex.

    Science.gov (United States)

    Hayes, Shawn G; McCord, Jennifer L; Rainier, Jon; Liu, Zhuqing; Kaufman, Marc P

    2008-10-01

    The exercise pressor reflex arises from contracting skeletal muscle and is believed to play a role in evoking the cardiovascular responses to static exercise, effects that include increases in arterial pressure and heart rate. This reflex is believed to be evoked by the metabolic and mechanical stimulation of thin fiber muscle afferents. Lactic acid is known to be an important metabolic stimulus evoking the reflex. Until recently, the only antagonist for acid-sensitive ion channels (ASICs), the receptors to lactic acid, was amiloride, a substance that is also a potent antagonist for both epithelial sodium channels as well as voltage-gated sodium channels. Recently, a second compound, A-317567, has been shown to be an effective and selective antagonist to ASICs in vitro. Consequently, we measured the pressor responses to the static contraction of the triceps surae muscles in decerebrate cats before and after a popliteal arterial injection of A-317567 (10 mM solution; 0.5 ml). We found that this ASIC antagonist significantly attenuated by half (Pacid injection into the popliteal artery. In contrast, A-317567 had no effect on the pressor responses to tendon stretch, a pure mechanical stimulus, and to a popliteal arterial injection of capsaicin, which stimulated transient receptor potential vanilloid type 1 channels. We conclude that ASICs on thin fiber muscle afferents play a substantial role in evoking the metabolic component of the exercise pressor reflex.

  16. Measures to suppress ignition risk on full-face heading machines

    Energy Technology Data Exchange (ETDEWEB)

    Seeliger, A; Marx, W -E; Radtke, H

    1987-12-01

    Within the Research Development project 'Measures to suppress ignition risk on full-facers' the Institute of Mechanical Engineering of the Westfaelische Berggewerkskasse (WBK) has formulated concepts to reduce the ignition danger caused by the cutting action of full-face heading machines. Since the cooling of the rock surface in the immediate vicinity of the roller bits represents an effective preventive measure against ignition of firedamp, the machine manufacturers recommend the installation of a nozzle close to each disc holder whose water jet hits the point immediately behind and on the roller bit itself. The shape of nozzles to be employed should be such that they generate a water jet whose fan is capable of creating air velocities of about 10 m/s along the cutting track of the roller bits. This will achieve an additional degree of safety from ignition of any firedamp that may be present, because the duration of a juxtaposition between a possible hot surface and firedamp for energy exchange is reduced. The water could be fed to the individual nozzles at a pressure of 60 to 80 bar through a rotary distributor in the borer head. Following an analysis of the most frequent ignition causes a rotation and temperature monitoring system was developed for the roller bits of a borer head. 5 figs.

  17. Intrasexual competition at work : Sex differences in the jealousy-evoking effect of rival characteristics in work settings

    NARCIS (Netherlands)

    Buunk, Abraham P.; 't Goor, Joel Aan; Solano, Alejandro C.

    Sex differences in jealousy-evoking rival characteristics in the relationship with a supervisor at work were examined in a community sample of 188 individuals from Argentina. Among men, the rivals' social dominance and communal attributes evoked the most jealousy, followed by physical dominance.

  18. The role of Magnetic Resonance Imaging and Visual Evoked ...

    African Journals Online (AJOL)

    Introduction: To report our experience in management of patients with optic neuritis. The effects of brain magnetic resonance imaging and visual evoked potential on management were investigated. Methods: This is a four years clinical trial that included patients presenting with first attack of optic neuritis older than 16 years ...

  19. Rotator cuff exercises

    Science.gov (United States)

    ... 25560729 . Read More Frozen shoulder Rotator cuff problems Rotator cuff repair Shoulder arthroscopy Shoulder CT scan Shoulder MRI scan Shoulder pain Patient Instructions Rotator cuff - self-care Shoulder surgery - discharge Using your ...

  20. Gender differences in head-neck segment dynamic stabilization during head acceleration.

    Science.gov (United States)

    Tierney, Ryan T; Sitler, Michael R; Swanik, C Buz; Swanik, Kathleen A; Higgins, Michael; Torg, Joseph

    2005-02-01

    Recent epidemiological research has revealed that gender differences exist in concussion incidence but no study has investigated why females may be at greater risk of concussion. Our purpose was to determine whether gender differences existed in head-neck segment kinematic and neuromuscular control variables responses to an external force application with and without neck muscle preactivation. Forty (20 females and 20 males) physically active volunteers participated in the study. The independent variables were gender, force application (known vs unknown), and force direction (forced flexion vs forced extension). The dependent variables were kinematic and EMG variables, head-neck segment stiffness, and head-neck segment flexor and extensor isometric strength. Statistical analyses consisted of multiple multivariate and univariate analyses of variance, follow-up univariate analyses of variance, and t-tests (P Gender differences existed in head-neck segment dynamic stabilization during head angular acceleration. Females exhibited significantly greater head-neck segment peak angular acceleration (50%) and displacement (39%) than males despite initiating muscle activity significantly earlier (SCM only) and using a greater percentage of their maximum head-neck segment muscle activity (79% peak activity and 117% muscle activity area). The head-neck segment angular acceleration differences may be because females exhibited significantly less isometric strength (49%), neck girth (30%), and head mass (43%), resulting in lower levels of head-neck segment stiffness (29%). For our subject demographic, the results revealed gender differences in head-neck segment dynamic stabilization during head acceleration in response to an external force application. Females exhibited significantly greater head-neck segment peak angular acceleration and displacement than males despite initiating muscle activity earlier (SCM only) and using a greater percentage of their maximum head-neck segment

  1. Prior Expectations Evoke Stimulus Templates in the Primary Visual Cortex

    NARCIS (Netherlands)

    Kok, P.; Failing, F.M.; de Lange, F.P.

    2014-01-01

    Exposure to rhythmic stimulation results in facilitated responses to events that appear in-phase with the rhythm and modulation of anticipatory and target-evoked brain activity, presumably reflecting "exogenous," unintentional temporal expectations. However, the extent to which this effect is

  2. Multimodal evoked potentials follow up in multiple sclerosis patients under fingolimod therapy

    DEFF Research Database (Denmark)

    Iodice, R; Carotenuto, A; Dubbioso, R

    2016-01-01

    related to EDSS at baseline (t=-1), while MEP and total EP sum score were related to EDSS at all time points. CONCLUSION: Fingolimod is able to improve visual and somatosensory evoked potential in RR-MS patients even if clinical disability scale remains stable. VEP and SEP could give eloquent information...... patients examined 12months prior to initiation of fingolimod (t=-1), at treatment initiation (t=0) and 1year later (t=+1) were compared. Each EP (VEP, MEP, SEP) and EP sum score, a global evoked potential score as the sum score of the each EP score was evaluated and correlated with Expanded Disability...

  3. A meta-analysis comparing tenotomy and tenodesis for treating rotator cuff tears combined with long head of the biceps tendon lesions.

    Directory of Open Access Journals (Sweden)

    Xiliang Shang

    Full Text Available The purpose of this meta-analysis was to assess whether there were differences in the outcomes between tenotomy and tenodesis in treating LHBT lesions combined with rotator cuff repairs.Using Medline, Embase, and Cochrane, we searched for articles comparing tenotomy and tenodesis combined with rotator cuff repair which were published before April 2016 with the terms "biceps", "tenotomy", "tenodesis", and "rotator cuff". The controlled clinical studies that met the inclusion and exclusion criteria were assessed for quality of methodology by utilizing the Coleman score.On the basis of the inclusion and exclusion criteria, ten articles (903 patients were included in this meta-analysis. The Coleman score ranged between 40 and 89 in the included studies. The results showed that the incidence of the popeye sign (OR, 2.777, P = 0.000 were higher in tenotomy group compared with tenodesis group when concomitant rotator cuff repair. Statistically significant difference in favor of tenodesis was observed for Constant score (SMD, -0.230, P = 0.025. As for the arm cramping pain, patient satisfaction, VAS score, ASES score and UCLA increased score, the strength and the range of motion, there were no significant differences between tenodesis and tenotomy of the LHBT, corresponding to the currently available results in the literature.Based on this meta-analysis, both tenotomy and tenodesis are effective in pain relief and function improvement in patients with repairable rotator cuff tears. No significant differences in post-operative functional outcome between tenotomy and tenodesis for the treatment of LHBT lesions were observed except for a lower Constant score and higher risk of Popeye deformity in tenotomy.

  4. Effect of mechanical tactile noise on amplitude of visual evoked potentials: multisensory stochastic resonance.

    Science.gov (United States)

    Méndez-Balbuena, Ignacio; Huidobro, Nayeli; Silva, Mayte; Flores, Amira; Trenado, Carlos; Quintanar, Luis; Arias-Carrión, Oscar; Kristeva, Rumyana; Manjarrez, Elias

    2015-10-01

    The present investigation documents the electrophysiological occurrence of multisensory stochastic resonance in the human visual pathway elicited by tactile noise. We define multisensory stochastic resonance of brain evoked potentials as the phenomenon in which an intermediate level of input noise of one sensory modality enhances the brain evoked response of another sensory modality. Here we examined this phenomenon in visual evoked potentials (VEPs) modulated by the addition of tactile noise. Specifically, we examined whether a particular level of mechanical Gaussian noise applied to the index finger can improve the amplitude of the VEP. We compared the amplitude of the positive P100 VEP component between zero noise (ZN), optimal noise (ON), and high mechanical noise (HN). The data disclosed an inverted U-like graph for all the subjects, thus demonstrating the occurrence of a multisensory stochastic resonance in the P100 VEP. Copyright © 2015 the American Physiological Society.

  5. The Head-Disk Interface Roadmap to an Areal Density of Tbit/in2

    Directory of Open Access Journals (Sweden)

    Bruno Marchon

    2013-01-01

    Full Text Available This paper reviews the state of the head-disk interface (HDI technology, and more particularly the head-medium spacing (HMS, for today’s and future hard-disk drives. Current storage areal density on a disk surface is fast approaching the one terabit per square inch mark, although the compound annual growth rate has reduced considerably from ~100%/annum in the late 1990s to 20–30% today. This rate is now lower than the historical, Moore’s law equivalent of ~40%/annum. A necessary enabler to a high areal density is the HMS, or the distance from the bottom of the read sensor on the flying head to the top of the magnetic medium on the rotating disk. This paper describes the various components of the HMS and various scenarios and challenges on how to achieve a goal of 4.0–4.5 nm for the 4 Tbit/in2 density point. Special considerations will also be given to the implication of disruptive technologies such as sealing the drive in an inert atmosphere and novel recording schemes such as bit patterned media and heat assisted magnetic recording.

  6. A new head-mounted display-based augmented reality system in neurosurgical oncology: a study on phantom.

    Science.gov (United States)

    Cutolo, Fabrizio; Meola, Antonio; Carbone, Marina; Sinceri, Sara; Cagnazzo, Federico; Denaro, Ennio; Esposito, Nicola; Ferrari, Mauro; Ferrari, Vincenzo

    2017-12-01

    Benefits of minimally invasive neurosurgery mandate the development of ergonomic paradigms for neuronavigation. Augmented Reality (AR) systems can overcome the shortcomings of commercial neuronavigators. The aim of this work is to apply a novel AR system, based on a head-mounted stereoscopic video see-through display, as an aid in complex neurological lesion targeting. Effectiveness was investigated on a newly designed patient-specific head mannequin featuring an anatomically realistic brain phantom with embedded synthetically created tumors and eloquent areas. A two-phase evaluation process was adopted in a simulated small tumor resection adjacent to Broca's area. Phase I involved nine subjects without neurosurgical training in performing spatial judgment tasks. In Phase II, three surgeons were involved in assessing the effectiveness of the AR-neuronavigator in performing brain tumor targeting on a patient-specific head phantom. Phase I revealed the ability of the AR scene to evoke depth perception under different visualization modalities. Phase II confirmed the potentialities of the AR-neuronavigator in aiding the determination of the optimal surgical access to the surgical target. The AR-neuronavigator is intuitive, easy-to-use, and provides three-dimensional augmented information in a perceptually-correct way. The system proved to be effective in guiding skin incision, craniotomy, and lesion targeting. The preliminary results encourage a structured study to prove clinical effectiveness. Moreover, our testing platform might be used to facilitate training in brain tumour resection procedures.

  7. Path integration of head direction: updating a packet of neural activity at the correct speed using axonal conduction delays.

    Science.gov (United States)

    Walters, Daniel; Stringer, Simon; Rolls, Edmund

    2013-01-01

    The head direction cell system is capable of accurately updating its current representation of head direction in the absence of visual input. This is known as the path integration of head direction. An important question is how the head direction cell system learns to perform accurate path integration of head direction. In this paper we propose a model of velocity path integration of head direction in which the natural time delay of axonal transmission between a linked continuous attractor network and competitive network acts as a timing mechanism to facilitate the correct speed of path integration. The model effectively learns a "look-up" table for the correct speed of path integration. In simulation, we show that the model is able to successfully learn two different speeds of path integration across two different axonal conduction delays, and without the need to alter any other model parameters. An implication of this model is that, by learning look-up tables for each speed of path integration, the model should exhibit a degree of robustness to damage. In simulations, we show that the speed of path integration is not significantly affected by degrading the network through removing a proportion of the cells that signal rotational velocity.

  8. SHOULDER EXTERNAL ROTATOR STRENGTH IN RESPONSE TO VARIOUS SITTING POSTURES: A CONTROLLED LABORATORY STUDY.

    Science.gov (United States)

    Pheasant, Steven; Haydt, Richard; Gottstein, Thomas; Grasso, Anthony; Lombard, Nicholas; Stone, Brandon

    2018-02-01

    The forward head rounded shoulder (FHRS) sitting posture has been associated with decreased shoulder complex muscle strength and function. Upon clinical observation, the adverse effects of the FHRS sitting posture on shoulder complex isometric muscle strength is also present when testing controls for scapular position. The purpose of the study was to assess the effect of various sitting postures on shoulder external rotator muscle isometric strength when the strength testing controls for scapular position. A cohort study, with subjects serving as their own controls. One hundred subjects ages 20-26 participated in the study. Each subject was placed in a neutral cervical sitting (NCS) posture which was maintained for five minutes after which the strength of the dominant shoulder external rotators was immediately tested with the glenohumeral joint in the neutral position using a Micro-FET3 Hand Held Muscle Testing Dynamometer (HHMTD). Each subject was returned to the NCS posture for subsequent external rotator strength testing after five minutes in a FHRS sitting posture, five additional minutes in the NCS posture and five minutes in a retracted cervical sitting (RCS) posture resulting in each subjects' external rotator strength being tested on four occasions. Subjects were randomized for order between the FHRS and RCS postures. Mean strength values for each condition were normalized to the mean strength value for the 1 st NCS condition for each subject. A statistically significant decline in shoulder external rotator strength following the FHRS sitting posture occurred compared to the appropriate postural conditions (pexternal rotator strength following five minutes in the FHRS sitting posture. The average percentage of strength decline in those with greater than a 10% reduction in external rotator strength was 19%. Sixty-four percent of the subjects experienced less than a 10% decline in shoulder external rotator strength in response to the FHRS sitting posture

  9. DC-Evoked Modulation of Excitability of Myelinated Nerve Fibers and Their Terminal Branches; Differences in Sustained Effects of DC.

    Science.gov (United States)

    Kaczmarek, Dominik; Jankowska, Elzbieta

    2018-03-15

    Direct current (DC) evokes long-lasting changes in neuronal networks both presynaptically and postsynaptically and different mechanisms were proposed to be involved in them. Different mechanisms were also suggested to account for the different dynamics of presynaptic DC actions on myelinated nerve fibers stimulated before they entered the spinal gray matter and on their terminal branches. The aim of the present study was to examine whether these different dynamics might be related to differences in the involvement of K + channels. To this end, we compared effects of the K + channel blocker 4-amino-pyridine (4-AP) on DC-evoked changes in the excitability of afferent fibers stimulated within the dorsal columns (epidurally) and within their projection areas in the dorsal horn and motor nuclei (intraspinally). 4-AP was applied systemically in deeply anesthetized rats. DC-evoked increases in the excitability of epidurally stimulated afferent nerve fibers, and increases in field potentials evoked by these fibers, were not affected by 4-AP. In contrast, sustained decreases rather than increases in the excitability of intraspinally stimulated terminal nerve branches were evoked by local application of DC in conjunction with 4-AP. The study leads to the conclusion that 4-AP-sensitive K + channels contribute to the sustained DC-evoked post-polarization increases in the excitability at the level of terminal branches of nerve fibers but not of the nodes of Ranvier nor within the juxta-paranodal regions where other mechanisms would be involved in inducing the sustained DC-evoked changes. Copyright © 2018 IBRO. Published by Elsevier Ltd. All rights reserved.

  10. Torque and mechanomyogram relationships during electrically-evoked isometric quadriceps contractions in persons with spinal cord injury.

    Science.gov (United States)

    Ibitoye, Morufu Olusola; Hamzaid, Nur Azah; Hasnan, Nazirah; Abdul Wahab, Ahmad Khairi; Islam, Md Anamul; Kean, Victor S P; Davis, Glen M

    2016-08-01

    The interaction between muscle contractions and joint loading produces torques necessary for movements during activities of daily living. However, during neuromuscular electrical stimulation (NMES)-evoked contractions in persons with spinal cord injury (SCI), a simple and reliable proxy of torque at the muscle level has been minimally investigated. Thus, the purpose of this study was to investigate the relationships between muscle mechanomyographic (MMG) characteristics and NMES-evoked isometric quadriceps torques in persons with motor complete SCI. Six SCI participants with lesion levels below C4 [(mean (SD) age, 39.2 (7.9) year; stature, 1.71 (0.05) m; and body mass, 69.3 (12.9) kg)] performed randomly ordered NMES-evoked isometric leg muscle contractions at 30°, 60° and 90° knee flexion angles on an isokinetic dynamometer. MMG signals were detected by an accelerometer-based vibromyographic sensor placed over the belly of rectus femoris muscle. The relationship between MMG root mean square (MMG-RMS) and NMES-evoked torque revealed a very high association (R(2)=0.91 at 30°; R(2)=0.98 at 60°; and R(2)=0.97 at 90° knee angles; Ptorque, between 0.65 and 0.79 for MMG-RMS, and from 0.67 to 0.73 for MMG-PTP. Their standard error of measurements (SEM) ranged between 10.1% and 31.6% (of mean values) for torque, MMG-RMS and MMG-PTP. The MMG peak frequency (MMG-PF) of 30Hz approximated the stimulation frequency, indicating NMES-evoked motor unit firing rate. The results demonstrated knee angle differences in the MMG-RMS versus NMES-isometric torque relationship, but a similar torque related pattern for MMG-PF. These findings suggested that MMG was well associated with torque production, reliably tracking the motor unit recruitment pattern during NMES-evoked muscle contractions. The strong positive relationship between MMG signal and NMES-evoked torque production suggested that the MMG might be deployed as a direct proxy for muscle torque or fatigue measurement during

  11. Synchronous Firefly Algorithm for Cluster Head Selection in WSN

    Directory of Open Access Journals (Sweden)

    Madhusudhanan Baskaran

    2015-01-01

    Full Text Available Wireless Sensor Network (WSN consists of small low-cost, low-power multifunctional nodes interconnected to efficiently aggregate and transmit data to sink. Cluster-based approaches use some nodes as Cluster Heads (CHs and organize WSNs efficiently for aggregation of data and energy saving. A CH conveys information gathered by cluster nodes and aggregates/compresses data before transmitting it to a sink. However, this additional responsibility of the node results in a higher energy drain leading to uneven network degradation. Low Energy Adaptive Clustering Hierarchy (LEACH offsets this by probabilistically rotating cluster heads role among nodes with energy above a set threshold. CH selection in WSN is NP-Hard as optimal data aggregation with efficient energy savings cannot be solved in polynomial time. In this work, a modified firefly heuristic, synchronous firefly algorithm, is proposed to improve the network performance. Extensive simulation shows the proposed technique to perform well compared to LEACH and energy-efficient hierarchical clustering. Simulations show the effectiveness of the proposed method in decreasing the packet loss ratio by an average of 9.63% and improving the energy efficiency of the network when compared to LEACH and EEHC.

  12. Intermediate Latency-Evoked Potentials of Multimodal Cortical Vestibular Areas: Galvanic Stimulation

    Directory of Open Access Journals (Sweden)

    Stefan Kammermeier

    2017-11-01

    Full Text Available IntroductionHuman multimodal vestibular cortical regions are bilaterally anterior insulae and posterior opercula, where characteristic vestibular-related cortical potentials were previously reported under acoustic otolith stimulation. Galvanic vestibular stimulation likely influences semicircular canals preferentially. Galvanic stimulation was compared to previously established data under acoustic stimulation.Methods14 healthy right-handed subjects, who were also included in the previous acoustic potential study, showed normal acoustic and galvanic vestibular-evoked myogenic potentials. They received 2,000 galvanic binaural bipolar stimuli for each side during EEG recording.ResultsVestibular cortical potentials were found in all 14 subjects and in the pooled data of all subjects (“grand average” bilaterally. Anterior insula and posterior operculum were activated exclusively under galvanic stimulation at 25, 35, 50, and 80 ms; frontal regions at 30 and 45 ms. Potentials at 70 ms in frontal regions and at 110 ms at all of the involved regions could also be recorded; these events were also found using acoustic stimulation in our previous study.ConclusionGalvanic semicircular canal stimulation evokes specific potentials in addition to those also found with acoustic otolith stimulation in identically located regions of the vestibular cortex. Vestibular cortical regions activate differently by galvanic and acoustic input at the peripheral sensory level.SignificanceDifferential effects in vestibular cortical-evoked potentials may see clinical use in specific vertigo disorders.

  13. Band head spin assignment of superdeformed bands in Hg isotopes through power index formula

    Science.gov (United States)

    Sharma, Honey; Mittal, H. M.

    2018-05-01

    The power index formula has been used to obtain the band head spin (I 0) of all the superdeformed (SD) bands in Hg isotopes. A least squares fitting approach is used. The root mean square deviations between the determined and the observed transition energies are calculated by extracting the model parameters using the power index formula. Whenever definite spins are available, the determined and the observed transition energies are in accordance with each other. The computed values of dynamic moment of inertia J (2) obtained by using the power index formula and its deviation with the rotational frequency is also studied. Excellent agreement is shown between the calculated and the experimental results for J (2) versus the rotational frequency. Hence, the power index formula works very well for all the SD bands in Hg isotopes expect for 195Hg(2, 3, 4).

  14. E 2 decay strength of the M 1 scissors mode of 156Gd and its first excited rotational state

    Science.gov (United States)

    Beck, T.; Beller, J.; Pietralla, N.; Bhike, M.; Birkhan, J.; Derya, V.; Gayer, U.; Hennig, A.; Isaak, J.; Löher, B.; Ponomarev, V. Yu.; Richter, A.; Romig, C.; Savran, D.; Scheck, M.; Tornow, W.; Werner, V.; Zilges, A.; Zweidinger, M.

    2017-05-01

    The E 2 /M 1 multipole mixing ratio δ1 →2 of the 1sc+→21+ γ -ray decay in 156Gd and hence the isovector E 2 transition rate of the scissors mode of a well-deformed rotational nucleus has been measured for the first time. It has been obtained from the angular distribution of an artificial quasimonochromatic linearly polarized γ -ray beam of energy 3.07(6) MeV scattered inelastically off an isotopically highly enriched 156Gd target. The data yield first direct support for the deformation dependence of effective proton and neutron quadrupole boson charges in the framework of algebraic nuclear models. First evidence for a low-lying Jπ=2+ member of the rotational band of states on top of the 1+ band head is obtained, too, indicating a significant signature splitting in the K =1 scissors mode rotational band.

  15. E2 decay strength of the M1 scissors mode of ^{156}Gd and its first excited rotational state.

    Science.gov (United States)

    Beck, T; Beller, J; Pietralla, N; Bhike, M; Birkhan, J; Derya, V; Gayer, U; Hennig, A; Isaak, J; Löher, B; Ponomarev, V Yu; Richter, A; Romig, C; Savran, D; Scheck, M; Tornow, W; Werner, V; Zilges, A; Zweidinger, M

    2017-05-26

    The E2/M1 multipole mixing ratio δ_{1→2} of the 1_{sc}^{+}→2_{1}^{+} γ-ray decay in ^{156}Gd and hence the isovector E2 transition rate of the scissors mode of a well-deformed rotational nucleus has been measured for the first time. It has been obtained from the angular distribution of an artificial quasimonochromatic linearly polarized γ-ray beam of energy 3.07(6) MeV scattered inelastically off an isotopically highly enriched ^{156}Gd target. The data yield first direct support for the deformation dependence of effective proton and neutron quadrupole boson charges in the framework of algebraic nuclear models. First evidence for a low-lying J^{π}=2^{+} member of the rotational band of states on top of the 1^{+} band head is obtained, too, indicating a significant signature splitting in the K=1 scissors mode rotational band.

  16. Automatic classification of visual evoked potentials based on wavelet decomposition

    Science.gov (United States)

    Stasiakiewicz, Paweł; Dobrowolski, Andrzej P.; Tomczykiewicz, Kazimierz

    2017-04-01

    Diagnosis of part of the visual system, that is responsible for conducting compound action potential, is generally based on visual evoked potentials generated as a result of stimulation of the eye by external light source. The condition of patient's visual path is assessed by set of parameters that describe the time domain characteristic extremes called waves. The decision process is compound therefore diagnosis significantly depends on experience of a doctor. The authors developed a procedure - based on wavelet decomposition and linear discriminant analysis - that ensures automatic classification of visual evoked potentials. The algorithm enables to assign individual case to normal or pathological class. The proposed classifier has a 96,4% sensitivity at 10,4% probability of false alarm in a group of 220 cases and area under curve ROC equals to 0,96 which, from the medical point of view, is a very good result.

  17. Rotational Grazing System for Beef Cows on Dwarf Elephantgrass Pasture for Two Years after Establishment

    Directory of Open Access Journals (Sweden)

    M Mukhtar

    2011-01-01

    Full Text Available An intensive rotational grazing system for dwarf and late heading (DL elephant grass (Pennisetum purpureum Schumach pasture was examined in a summer period for two years following establishment. Four 0.05 of DL elephant grass pastures (20×25 m were established on May 2003. They were rotationally grazed for 1 week, followed by a 3-week rest period by three breeding or raising beef cattle for three and six cycles during the first and second years of establishment respectively. Before grazing, the plant height, leaf area index and the ratio of leaf blade to stem were at the highest, while tiller number increased and herbage mass tended to increase, except for the first grazing cycle both two years and for one paddock in the second year. Herbage consumption, the rate of herbage consumption and dry matter intake tended to decrease in three paddocks from the first to the third cycle in the first year, but increase as grazing occurred in the second year. Dry matter intake averaged 10.2-14.5 and 15.4–23.2 g DM/kg/live weight (LW/day over the four paddocks in the first and second year, respectively, and average daily gains were 0.09 and 0.35 kg/head/day in the first and second year respectively. The carrying capacities were estimated at 1,016 and 208 cow-days (CD/ha (annual total 1,224 CD/ha in the first year and 1,355 and 207 CD/ha (annual total 1,562 CD/ha in the second year. Thus, DL elephant grass pasture can expand the grazing period for beef cows for the following two-year establishment. (Animal Production 13(1:10-17 (2011 Key Words: dwarf elephant grass, herbage mass, plant characters, rotational grazing

  18. Thermal grill-evoked sensations of heat correlate with cold pain threshold and are enhanced by menthol and cinnamaldehyde.

    Science.gov (United States)

    Averbeck, B; Rucker, F; Laubender, R P; Carr, R W

    2013-05-01

    Thunberg's thermal grill produces a sensation of strong heat upon skin contact with spatially interlaced innocuous warm and cool stimuli. To examine the classes of peripheral axons that might contribute to this illusion, the effects of topical l-menthol, an activator of TRPM8, and cinnamaldehyde, a TRPA1 agonist, on the magnitude of thermal sensations were examined during grill stimulation in healthy volunteers. Under control conditions, cutaneous grill stimulation (interlaced 20/40 °C) evoked a sensation of heat, and for individual subjects, the magnitude of this heat sensation was positively correlated with cold pain threshold (CPT). Menthol increased the CPT and enhanced the magnitude of grill-evoked heat. Cinnamaldehyde intensified warm sensations, reduced heat pain threshold and also enhanced grill-evoked heat. Both TRPM8-expressing and TRPA1-expressing afferent axons can affect grill-evoked thermal sensations. The enhancement of grill-evoked sensations of temperature with menthol and cinnamaldehyde may provide an additional clinically relevant means of testing altered thermal sensitivity, which is often affected in neuropathic patient groups. © 2012 European Federation of International Association for the Study of Pain Chapters.

  19. Trabecular microstructure and surface changes in the greater tuberosity in rotator cuff tears

    International Nuclear Information System (INIS)

    Jiang, Yebin; Zhao, Jenny; Ouyang, Xiaolong; Genant, Harry K.; Holsbeeck, Marnix T. van; Flynn, Michael J.

    2002-01-01

    Abstract Objective. When planning surgery in patients with rotator cuff tear, strength of bone at the tendon insertion and trabecular bone structure in the greater tuberosity are usually taken into consideration. We investigated radiographic changes in bone structure of the greater tuberosity in rotator cuff tears.Design. Twenty-two human cadaveric shoulders from subjects ranging from 55 to 75 years of age were obtained. The integrity of the rotator cuff was examined by sonography to determine if it is intact without any tear, or torn partially or completely. The humeral head was sectioned in 3 mm thick coronal slab sections and microradiographed. After digitization of the microradiographs and imaging processing with in-house semi-automated image processing software tools developed using software interfaces on a Sun workstation, the trabecular histomorphometrical structural parameters and connectivity in the greater tuberosity were quantified. The degenerative changes on the surface of the greater tuberosity were interpreted blindly by 2 independent readers.Results. Among the 22 shoulder specimens, the rotator cuff was found intact in 10 shoulders, partially in 7 and fully torn in 5. Statistically significant loss in apparent trabecular bone volume fraction, number of trabecular nodes, and number of trabecular branches, and a statistically significant increase in apparent trabecular separation and number of trabecular free ends were found in the greater tuberosity of the shoulders with tears. The loss was greater in association with full tear than in partial tear. Thickening of the cortical margin of the enthesis, irregularity of its surface, and calcification beyond the tidemark were observed in 2 (20%) shoulders with intact rotator cuff, in 6 (86%) shoulders with partial tear, and in 5 (100%) shoulders with full tear.Conclusions. Rotator cuff tears are associated with degenerative changes on the bone surface and with disuse osteopenia of the greater tuberosity

  20. Neurophysiological mechanisms of bradykinin-evoked mucosal chloride secretion in guinea pig small intestine.

    Science.gov (United States)

    Qu, Mei-Hua; Ji, Wan-Sheng; Zhao, Ting-Kun; Fang, Chun-Yan; Mao, Shu-Mei; Gao, Zhi-Qin

    2016-02-15

    To investigate the mechanism for bradykinin (BK) to stimulate intestinal secretomotor neurons and intestinal chloride secretion. Muscle-stripped guinea pig ileal preparations were mounted in Ussing flux chambers for the recording of short-circuit current (Isc). Basal Isc and Isc stimulated by BK when preincubated with the BK receptors antagonist and other chemicals were recorded using the Ussing chamber system. Prostaglandin E2 (PGE2) production in the intestine was determined by enzyme immunologic assay (EIA). Application of BK or B2 receptor (B2R) agonist significantly increased the baseline Isc compared to the control. B2R antagonist, tetrodotoxin and scopolamine (blockade of muscarinic receptors) significantly suppressed the increase in Isc evoked by BK. The BK-evoked Isc was suppressed by cyclooxygenase (COX)-1 or COX-2 specific inhibitor as well as nonselective COX inhibitors. Preincubation of submucosa/mucosa preparations with BK for 10 min significantly increased PGE2 production and this was abolished by the COX-1 and COX-2 inhibitors. The BK-evoked Isc was suppressed by nonselective EP receptors and EP4 receptor antagonists, but selective EP1 receptor antagonist did not have a significant effect on the BK-evoked Isc. Inhibitors of PLC, PKC, calmodulin or CaMKII failed to suppress BK-induced PGE2 production. The results suggest that BK stimulates neurogenic chloride secretion in the guinea pig ileum by activating B2R, through COX increasing PGE2 production. The post-receptor transduction cascade includes activation of PLC, PKC, CaMK, IP3 and MAPK.