WorldWideScience

Sample records for head protective devices

  1. Protective device for the head of a gushing well

    Energy Technology Data Exchange (ETDEWEB)

    Kutepov, A.I.; Prokopov, O.I.

    1982-01-01

    A protective device is proposed for the head of a gushing well. It includes a housing with assembly for attachment to the pipe string. It is distinguished by the fact that in order to simplify insulation of the device at the well head and to improve its reliable operation, the housing is made in the form of sections, each of which is made in the form of a crimped sleeve with upper and lower flanges on the ends. The lower flange is equipped with a guide bushing installed inside the sleeve and clamps for attaching it in relation to the upper flange.

  2. An investigation into the effect of protective devices on the dose to radiosensitive organs in the head and neck

    International Nuclear Information System (INIS)

    Marshall, N.W.; Faulkner, K.; Clarke, P.

    1992-01-01

    A series of experiments were performed to determine the dose reduction afforded to radiosensitive organs in the head and neck by various protective devices. These included spectacles with plastic, standard glass, photochromic and lead-glass lenses, a thyroid collar and a lead-acrylic face mask. The measurements were performed using an anthropomorphic phantom loaded with lithium fluoride thermoluminescent dosemeters, in conditions realistic of clinical practice. Irradiations were performed using scattered radiation produced by a pelvic phantom, for X-ray beams generated at 80 kVp and 110 KVp. Also presented is the ratio of organ dose to dose to the bridge of the nose for thyroid, oesophagus, brain and sinuses, as measured for the case of no head or neck protection. (author)

  3. 29 CFR 1918.103 - Head protection.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Head protection. 1918.103 Section 1918.103 Labor... must ensure that head protection complies with any of the following consensus standards: (i) ANSI Z89.1... as head protection devices that are constructed in accordance with one of the above consensus...

  4. 29 CFR 1915.155 - Head protection.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Head protection. 1915.155 Section 1915.155 Labor... helmets. (1) Head protection must comply with any of the following consensus standards: (i) ANSI Z89.1... as head protection devices that are constructed in accordance with one of the above consensus...

  5. Protective head of sensors

    International Nuclear Information System (INIS)

    Liska, K.; Anton, P.

    1987-01-01

    The discovery concerns the protective heads of diagnostic assemblies of nuclear power plants for conductors of the sensors from the fuel and control parts of the said assemblies. A detailed description is presented of the design of the protective head which, as compared with the previous design, allows quick and simple assembly with reduced risk of damaging the sensors. The protective head may be used for diagnostic assemblies both in power and in research reactors and it will be used for WWER reactor assemblies. (A.K.). 3 figs

  6. 29 CFR 1926.100 - Head protection.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 8 2010-07-01 2010-07-01 false Head protection. 1926.100 Section 1926.100 Labor... § 1926.100 Head protection. (a) Employees working in areas where there is a possible danger of head... protected by protective helmets. (b) Helmets for the protection of employees against impact and penetration...

  7. 29 CFR 1910.135 - Head protection.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 5 2010-07-01 2010-07-01 false Head protection. 1910.135 Section 1910.135 Labor... head protection. (1) Head protection must comply with any of the following consensus standards: (i... consensus standards will be deemed to be in compliance with the requirements of this section. [59 FR 16362...

  8. Protection device for a thermonuclear device

    International Nuclear Information System (INIS)

    Kawashima, Shuichi.

    1986-01-01

    Purpose: To exactly detect the void coefficients of coolants even under high magnetic fields thereby detect the overheat of a thermonuclear device at an early stage. Constitution: The protecting device of this invention comprises a laser beam generation device, a laser beam detection device and an accident detection device. The laser generation device always generates laser beams, which are permeated through coolants and detected by the laser beam detection device, the optical amount of which is transmitted to the accident detection device. The accident detection device judges the excess or insufficiency of the detected optical amount with respect to the optical amount of the laser beams under the stationary state as a reference and issues an accident signal. Since only the optical cables that do not undergo the effect of the magnetic fields are exposed to high magnetic fields in the protection device of this invention, a high reliability can be maintained. (Kamimura, M.)

  9. 49 CFR 214.113 - Head protection.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Head protection. 214.113 Section 214.113 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... conform to the national consensus standards for industrial head protection (American National Standards...

  10. Reactor protecting device

    International Nuclear Information System (INIS)

    Ono, Hiroshi; Kasuga, Hajime; Kasuga, Hiroshi.

    1984-01-01

    Purpose: To reduce the recycling flowrate thereby decrease the neutron flux level before the reactor shutdown upon generation of abnormality such as increase in the neutron flux, by setting the safety level lower than the value for generating the reaction scram signal. Constitution: A netron flux safety level setter and an instruction signal generator are disposed between a neutron flux detector and a recycling flowrate control device. A neutron flux safety level lower than the level for generating a reactor scram signal and higher that the level for the ordinary operation is set and, if the detection level for the neutron flux in the reactor core arrives at the safety level, a neutron flux decreasing instruction signal is outputted from the instruction signal generator to the recycling flowrate control device to thereby decrease the recycling flowrate and decrease the neutron flux without reaching the reactor shutdown, whereby the thermal safety of the fuel rod can be maintained and the reactor operation performance can be improved. (Moriyama, K.)

  11. 33 CFR 142.30 - Head protection.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Head protection. 142.30 Section 142.30 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OUTER... protection. (a) Personnel in areas where there is a hazard of falling objects or of contact with electrical...

  12. Radiation leaking protection device

    International Nuclear Information System (INIS)

    Sunami, Yoshio; Mitsumori, Kojiro

    1980-01-01

    Purpose: To prevent radioactivity from leaking outside of a reactor container by way of pipeways passing therethrough, by supplying pressurized fluid between each of a plurality of valves for separating the pipeways. Constitution: Pressurized fluid is supplied between each of a plurality of valves for separating pipeways. For instance, water in a purified water tank is pressurized by a pressure pump and the pressure of the pressurized water is controlled by a differential pressure detector, a pressure controller and a pressure control valve. In the case if a main steam pipe is ruptured outside of the reactor container or to be repaired, the separation valves are wholly closed and then the pressurizing device is actuated to supply pressurized water containing no radioactivity from the purified water tank to the position between the valves. The pressure in the pressurized water is controlled such that it is always higher by a predetermined level than the pressure in the reactor. This prevents the radioacitivity in the reactor core from leaking outside of the container passing through the valves, whereby radiation exposure in the working can be reduced and the circumferential contamination upon accident of pipeway rupture can be decreased. (Kawakami, Y.)

  13. Reactor protection device

    Energy Technology Data Exchange (ETDEWEB)

    Shida, T; Hirose, M

    1977-01-19

    Purpose: To prevent abrupt increase or decrease in the recycling flow rate by comparing output signals from controllers in each of the loops in the recycling flow rate control system to lock the positions of fluid coupling scooping pipes or flow control valves corresponding to the groups generating abnormal signals. Constitution: The recycling flow rate is controlled by the r.p.m. of a motor directly coupled with a recycling pump and the value of r.p.m. is in proportion to the generator frequency varied with the sliding operation of the fluid coupling in MG set. The sliding operation of the fluid coupling is adjusted by a scooping pipe driver. When the device is set to automatic operation, the output signal of the main controller is delivered to the recycling flow rate control system, the output signal of which is input to respective scooping pipe drivers. The loop output signals are supplied to an adder where the deviation signal between both of them are detected and the scooping pipe is locked if the set value is exceeded.

  14. Reactor protection device

    International Nuclear Information System (INIS)

    Shida, Toichi; Hirose, Masao.

    1977-01-01

    Purpose: To prevent abrupt increase or decrease in the recycling flow rate by comparing output signals from controllers in each of the loops in the recycling flow rate control system to thereby lock the positions of fluid coupling scooping pipes or flow control valves corresponding to the groups generating abnormal signals. Constitution: The recycling flow rate is controlled by r.p.m. of a motor directly coupled with a recycling pump and the value of r.p.m. is in proportion to the generator frequency varied with the sliding operation of the fluid coupling in MG set. The sliding operation of the fluid coupling is adjusted by a scooping pipe driver. When the device is set to automatic operation, the output signal of the main controller is delivered to the recycling flow rate control system, the output signal of which is input to respective scooping pipe drivers. The loop output signals are supplied to an adder where the deviation signal between both of them are detected and the scooping pipe is locked if the set value is exceeded. (Yoshino, M.)

  15. 29 CFR 1917.93 - Head protection.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Head protection. 1917.93 Section 1917.93 Labor Regulations... of the following consensus standards: (i) ANSI Z89.1-2003, “American National Standard for Industrial... constructed in accordance with one of the above consensus standards will be deemed to be in compliance with...

  16. A new 3-dimensional head fixation device for brain imaging

    International Nuclear Information System (INIS)

    Goto, Ryoi; Kawashima, Ryuta; Yoshioka, Seiro; Ono, Shuichi; Ito, Hiroshi; Sato, Kazunori; Akaizawa, Takashi; Koyama, Masamichi; Fukuda, Hiroshi

    1995-01-01

    We have developed a new head fixation device for studies of brain function. This device was designed to immobilize subject's heads during image scanning and to precisely reproduce the head position for two different imaging modalities such as MRI and PET. The device consists of a plastic frame, a pillow filled with beads of styrene foam, and a face mask of thermoplastic resin which was originally intended for application in radiotherapy. A bridge for biting was incorporated into the mask for stable fixation. The device enables immobilization of subject's heads with good reproducibility of position at the practical level. Our results indicate that this head fixation system is useful for fixation of head during activation studies using PET. (author)

  17. Head-Impact–Measurement Devices: A Systematic Review

    Science.gov (United States)

    O'Connor, Kathryn L.; Rowson, Steven; Duma, Stefan M.; Broglio, Steven P.

    2017-01-01

    Context: With an estimated 3.8 million sport- and recreation-related concussions occurring annually, targeted prevention and diagnostic methods are needed. Biomechanical analysis of head impacts may provide quantitative information that can inform both prevention and diagnostic strategies. Objective: To assess available head-impact devices and their clinical utility. Data Sources: We performed a systematic search of the electronic database PubMed for peer-reviewed publications, using the following phrases: accelerometer and concussion, head impact telemetry, head impacts and concussion and sensor, head impacts and sensor, impact sensor and concussion, linear acceleration and concussion, rotational acceleration and concussion, and xpatch concussion. In addition to the literature review, a Google search for head impact monitor and concussion monitor yielded 15 more devices. Study Selection: Included studies were performed in vivo, used commercially available devices, and focused on sport-related concussion. Data Extraction: One author reviewed the title and abstract of each study for inclusion and exclusion criteria and then reviewed each full-text article to confirm inclusion criteria. Controversial articles were reviewed by all authors to reach consensus. Data Synthesis: In total, 61 peer-reviewed articles involving 4 head-impact devices were included. Participants in boxing, football, ice hockey, soccer, or snow sports ranged in age from 6 to 24 years; 18% (n = 11) of the studies included female athletes. The Head Impact Telemetry System was the most widely used device (n = 53). Fourteen additional commercially available devices were presented. Conclusions: Measurements collected by impact monitors provided real-time data to estimate player exposure but did not have the requisite sensitivity to concussion. Proper interpretation of previously reported head-impact kinematics across age, sport, and position may inform future research and enable staff clinicians

  18. Nuclear reactor safety protection device

    International Nuclear Information System (INIS)

    Okido, Fumiyasu; Noguchi, Atomi; Matsumiya, Shoichi; Furusato, Ken-ichiro; Arita, Setsuo.

    1994-01-01

    The device of the present invention extremely reduces a probability of causing unnecessary scram of a nuclear reactor. That is, four control devices receive signals from each of four sensors and output four trip signals respectively in a quardruplicated control device. Each of the trip signals and each of trip signals via a delay circuit are inputted to a logical sum element. The output of the logical sum circuit is inputted to a decision of majority circuit. The decision of majority circuit controls a scram pilot valve which conducts scram of the reactor by way of a solenoid coils. With such procedures, even if surge noises of a short pulse width are mixed to the sensor signals and short trip signals are outputted, there is no worry that the scram pilot valve is actuated. Accordingly, factors of lowering nuclear plant operation efficiency due to erroneous reactor scram can be reduced. (I.S.)

  19. Gate protective device for SOS array

    Science.gov (United States)

    Meyer, J. E., Jr.; Scott, J. H.

    1972-01-01

    Protective gate device consisting of alternating heavily doped n(+) and p(+) diffusions eliminates breakdown voltages in silicon oxide on sapphire arrays caused by electrostatic discharge from person or equipment. Diffusions are easily produced during normal double epitaxial processing. Devices with nine layers had 27-volt breakdown.

  20. Medical Devices; Obstetrical and Gynecological Devices; Classification of the Fetal Head Elevator. Final order.

    Science.gov (United States)

    2017-12-19

    The Food and Drug Administration (FDA or we) is classifying the fetal head elevator into class II (special controls). The special controls that apply to the device type are identified in this order and will be part of the codified language for the fetal head elevator's classification. We are taking this action because we have determined that classifying the device into class II (special controls) will provide a reasonable assurance of safety and effectiveness of the device. We believe this action will also enhance patients' access to beneficial innovative devices, in part by reducing regulatory burdens.

  1. Protection for a thermonuclear device

    International Nuclear Information System (INIS)

    Shimada, Ryuichi; Sasatani, Shin-ichi.

    1983-01-01

    Purpose: To suppress an abnormal voltage due to potential changes by a characteristic impedance composed of a discharge gap, a resistance and a capacitor, as well as absorb the energy of the abnormal voltage by properly selecting the current capacity of the resistor. Constitution: An abnormal voltage generated in a current transformer coils is detected by an abnormal voltage detector and an output signal therefrom causes a high voltage generating device to generate a high voltage, whereby electric discharge is taken place across a discharge gap to absorb the energy of the abnormal voltage in a resistor and a capacitor. For the abnormal voltage from the plasmas, the voltage across the transformer coils can be suppressed to some extent by selecting the impedance for the current transformer coils and the impedance for the parallel circuit of the resistor and the capacitor to an appropriate ratio. While on the other hand, after throwing a switcher by the actuation of a switcher control device, the energy for the abnormal voltage can sufficiently be absorbed through the internal resistance of the transformer coils and the resistance for the entire current. (Yoshino, Y.)

  2. High energy overcurrent protective device

    Science.gov (United States)

    Praeg, Walter F.

    1982-01-01

    Electrical loads connected to capacitance elements in high voltage direct current systems are protected from damage by capacitance discharge overcurrents by connecting between the capacitance element and the load, a longitudinal inductor comprising a bifilar winding wound about a magnetic core, which forms an incomplete magnetic circuit. A diode is connected across a portion of the bifilar winding which conducts a unidirectional current only. Energy discharged from the capacitance element is stored in the inductor and then dissipated in an L-R circuit including the diode and the coil winding. Multiple high voltage circuits having capacitance elements may be connected to loads through bifilar windings all wound about the aforementioned magnetic core.

  3. Medical devices of the head, neck, and spine.

    Science.gov (United States)

    Hunter, Tim B; Yoshino, Mark T; Dzioba, Robert B; Light, Rick A; Berger, William G

    2004-01-01

    There are many medical devices used for head, neck, and spinal diseases and injuries, and new devices are constantly being introduced. Many of the newest devices are variations on a previous theme. Knowing the specific name of a device is not important. It is important to recognize the presence of a device and to have an understanding of its function as well as to be able to recognize the complications associated with its use. The article discusses the most common and important devices of the head, neck, and spine, including cerebrospinal fluid shunts and the Codman Hakim programmable valve; subdural drainage catheters, subdural electrodes, intracranial electrodes, deep brain stimulators, and cerebellar electrodes; coils, balloons, adhesives, particles, and aneurysm clips; radiation therapy catheters, intracranial balloons for drug installation, and carmustine wafers; hearing aids, cochlear implants, and ossicular reconstruction prostheses; orbital prostheses, intraocular silicone oil, and lacrimal duct stents; anterior and posterior cervical plates, posterior cervical spine wiring, odontoid fracture fixation devices, cervical collars and halo vests; thoracic and lumbar spine implants, anterior and posterior instrumentation for the thoracic and lumbar spine, vertebroplasty, and artificial disks; spinal column stimulators, bone stimulators, intrathecal drug delivery pumps, and sacral stimulators; dental and facial implant devices; gastric and tracheal tubes; vagus nerve stimulators; lumboperitoneal shunts; and temperature- and oxygen-sensing probes. Copyright RSNA, 2004

  4. Protective device for battery to protect against heavy discharge

    Energy Technology Data Exchange (ETDEWEB)

    1979-02-08

    The protective device according to the invention switches the equipment being supplied from the battery at a pre-determined discharge voltage by means of a switching device controlled by monitoring equipment. A semi-conductor element is used as the switching device. The current taken from the battery flows through the semi-conductor element to the equipment and to the monitoring device. When the discharge voltage is reached the semi-conductor element blocks. The semi-conductor switch can consist of transistors. The invention is explained by means of drawings and examples.

  5. Simple overlay device for determining radial head and neck height

    International Nuclear Information System (INIS)

    Moon, Jun-Gyu; Southgate, Richard D.; Fitzsimmons, James S.; O'Driscoll, Shawn W.

    2010-01-01

    The purpose of this study was to test the hypothesis that a simple overlay device can be used on radiographs to measure radial head and neck height. Thirty anteroposterior elbow radiographs from 30 patients with a clinical diagnosis of lateral epicondylitis were examined to measure radial head and neck height. Three methods using different points along the bicipital tuberosity as a landmark were used. Method 1 used the proximal end of the bicipital tuberosity, method 2 used the most prominent point of the bicipital tuberosity, and method 3 used a simple overlay device (SOD) template that was aligned with anatomic reference points. All measurements were performed three times by three observers to determine interobserver and intraobserver reliability. Intraclass correlation coefficients revealed higher interobserver and intraobserver correlations for the SOD template method than for the other two methods. The 95% limits of agreement between observers were markedly better (-1.8 mm to +1.0 mm) for the SOD template method than for the proximal point method (-3.8 mm to +3.4 mm) or the prominent point method (-5.9 mm to +4.9 mm). We found that the SOD template method was reliable for assessing radial head and neck height. It had less variability than other methods, its 95% limit of agreement being less than 2 mm. This method could be helpful for assessing whether or not the insertion of a radial head prosthesis has resulted in over-lengthening of the radius. (orig.)

  6. Simple overlay device for determining radial head and neck height

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Jun-Gyu; Southgate, Richard D.; Fitzsimmons, James S.; O' Driscoll, Shawn W. [Mayo Clinic, Department of Orthopaedic Surgery, Rochester, MN (United States)

    2010-09-15

    The purpose of this study was to test the hypothesis that a simple overlay device can be used on radiographs to measure radial head and neck height. Thirty anteroposterior elbow radiographs from 30 patients with a clinical diagnosis of lateral epicondylitis were examined to measure radial head and neck height. Three methods using different points along the bicipital tuberosity as a landmark were used. Method 1 used the proximal end of the bicipital tuberosity, method 2 used the most prominent point of the bicipital tuberosity, and method 3 used a simple overlay device (SOD) template that was aligned with anatomic reference points. All measurements were performed three times by three observers to determine interobserver and intraobserver reliability. Intraclass correlation coefficients revealed higher interobserver and intraobserver correlations for the SOD template method than for the other two methods. The 95% limits of agreement between observers were markedly better (-1.8 mm to +1.0 mm) for the SOD template method than for the proximal point method (-3.8 mm to +3.4 mm) or the prominent point method (-5.9 mm to +4.9 mm). We found that the SOD template method was reliable for assessing radial head and neck height. It had less variability than other methods, its 95% limit of agreement being less than 2 mm. This method could be helpful for assessing whether or not the insertion of a radial head prosthesis has resulted in over-lengthening of the radius. (orig.)

  7. Device Data Protection in Mobile Healthcare Applications

    Science.gov (United States)

    Weerasinghe, Dasun; Rajarajan, Muttukrishnan; Rakocevic, Veselin

    The rapid growth in mobile technology makes the delivery of healthcare data and services on mobile phones a reality. However, the healthcare data is very sensitive and has to be protected against unauthorized access. While most of the development work on security of mobile healthcare today focuses on the data encryption and secure authentication in remote servers, protection of data on the mobile device itself has gained very little attention. This paper analyses the requirements and the architecture for a secure mobile capsule, specially designed to protect the data that is already on the device. The capsule is a downloadable software agent with additional functionalities to enable secure external communication with healthcare service providers, network operators and other relevant communication parties.

  8. Integration Head Mounted Display Device and Hand Motion Gesture Device for Virtual Reality Laboratory

    Science.gov (United States)

    Rengganis, Y. A.; Safrodin, M.; Sukaridhoto, S.

    2018-01-01

    Virtual Reality Laboratory (VR Lab) is an innovation for conventional learning media which show us whole learning process in laboratory. There are many tools and materials are needed by user for doing practical in it, so user could feel new learning atmosphere by using this innovation. Nowadays, technologies more sophisticated than before. So it would carry in education and it will be more effective, efficient. The Supported technologies are needed us for making VR Lab such as head mounted display device and hand motion gesture device. The integration among them will be used us for making this research. Head mounted display device for viewing 3D environment of virtual reality laboratory. Hand motion gesture device for catching user real hand and it will be visualized in virtual reality laboratory. Virtual Reality will show us, if using the newest technologies in learning process it could make more interesting and easy to understand.

  9. Developing biomedical devices design, innovation and protection

    CERN Document Server

    Andreoni, Giuseppe; Colombo, Barbara

    2013-01-01

    During the past two decades incredible progress has been achieved in the instruments and devices used in the biomedical field. This progress stems from continuous scientific research that has taken advantage of many findings and advances in technology made available by universities and industry. Innovation is the key word, and in this context legal protection and intellectual property rights (IPR) are of crucial importance. This book provides students and practitioners with the fundamentals for designing biomedical devices and explains basic design principles. Furthermore, as an aid to the dev

  10. Differential protective effects of motorcycle helmets against head injury.

    Science.gov (United States)

    Singleton, Michael D

    2017-05-19

    Although numerous observational studies have demonstrated a protective effect of motorcycle helmets against head injury, the degree of protection against specific head injury types remains unclear. Experimental biomechanics studies involving cadavers, animals, and computer models have established that head injuries have varying etiologies. This retrospective cross-sectional study compared helmet protection against skull fracture, cerebral contusion, intracranial hemorrhage, and cerebral concussion in a consecutive series of motorcycle operators involved in recent traffic crashes in Kentucky. Police collision reports linked to hospital inpatient and emergency department (ED) claims were analyzed for the period 2008 to 2012. Motorcycle operators with known helmet use who were not killed at the crash scene were included in the study. Helmet use was ascertained from the police report. Skull fracture, cerebral contusion, intracranial hemorrhage, and cerebral concussion were identified from International Classification of Diseases, Ninth Revision, Clinical Modification (ICD-9-CM) codes on the claims records. The relative risks of each type of head injury for helmeted versus unprotected operators were estimated using generalized estimating equations. Helmets offer substantial protection against skull fracture (relative risk [RR] = 0.31, 95% confidence interval [CI], 0.23, 0.34), cerebral contusion (RR = 0.29, 95% CI, 0.16, 0.53), and intracranial hemorrhage (RR = 0.47, 95% CI, 0.35, 0.63). The findings pertaining to uncomplicated concussion (RR = 0.80, 95% CI, 0.64, 1.01) were inconclusive. A modest protective effect (20% risk reduction) was suggested by the relative risk estimate, but the 95% confidence interval included the null value. Motorcycle helmets were associated with a 69% reduction in skull fractures, 71% reduction in cerebral contusion, and 53% reduction in intracranial hemorrhage. This study finds that current motorcycle helmets do not protect equally against

  11. Guidelines for selection of radiological protective head covering

    International Nuclear Information System (INIS)

    Galloway, G.R. Jr.

    1995-08-01

    The hood is recognized throughout the nuclear industry as the standard radiological protective head covering for use in radioactively contaminated work environments. As of June 15, 1995, hoods were required for all activities performed in contaminated areas at the Y-12 Plant. The use of hoods had historically been limited to those radiological activities with a high potential for personnel contamination. Due to the large size of many posted contaminated areas at the Y-12 Plant, and compounding safety factors, requirements for the use of hoods are being reevaluated. The purpose of the evaluation is to develop technically sound guidelines for the selection of hoods when prescribing radiological protective head covering. This report presents the guidelines for selection of radiological protective hoods

  12. Hybrid III anthropomorphic test device (ATD) response to head impacts and potential implications for athletic headgear testing.

    Science.gov (United States)

    Bartsch, Adam; Benzel, Edward; Miele, Vincent; Morr, Douglas; Prakash, Vikas

    2012-09-01

    The Hybrid III 50th percentile male anthropomorphic test device (ATD) is the most widely used human impact testing surrogate and has historically been used in automotive or military testing. More recently, this ATD is finding use in applications evaluating athletic helmet protectivity, quantifying head impact dosage and estimating injury risk. But ATD head-neck response has not been quantified in omnidirectional athletic-type head impacts absent axial preload. It is probable that headgear injury reduction that can be quantified in a laboratory, including in American football, boxing, hockey, lacrosse and soccer, is related to a number of interrelated kinetic and kinematic factors, such as head center of gravity linear acceleration, head angular acceleration, head angular velocity, occipito-cervical mechanics and neck stiffness. Therefore, we characterized ATD head-neck dynamic response to direct head impacts in a series of front, oblique front and lateral head impacts. Key findings were: (1) impacts producing highest ATD resultant center of gravity linear acceleration resulted in the lowest resultant occipito-cervical spine bending moment/force. (2) Resultant ATD head angular velocity and angular acceleration did not appear coupled to impact direction at lower impact energy levels; these parameters were coupled at higher energy levels. (3) The ATD had progressively increasing occipito-cervical stiffness in extension, torsion and lateral bending, respectively. Because the ATD neck influenced head and neck impact dosage parameters, testing agencies, manufacturers and researchers should consider using the Hybrid III head form attached to a neck as a means to quantify head and neck injury risks as opposed to systems that do not utilize a neck. This heightened understanding of Hybrid III ATD head-neck response, and consideration of order of stiffest axes in the lateral, oblique and extension directions, respectively, should aid in the development of head and neck injury

  13. Passive Cushiony Biomechanics of Head Protection in Falling Geckos

    Directory of Open Access Journals (Sweden)

    Hao Wang

    2018-01-01

    Full Text Available Gekko geckos are capable to crawl on the steep even on upside-down surfaces. Such movement, especially at great altitude, puts them at high risks of incidentally dropping down and inevitable body or head impactions, though they may trigger air-righting reaction (ARR to attenuate the landing shocks. However, the air-righting ability (ARA in Gekko geckos is not fully developed. The implementation of ARR in some geckos is quite slow; and for those without tails, the ARR is even unobservable. Since ARA is compromised in Gekko geckos, there must be some other mechanisms responsible for protecting them from head injuries during falls. In this study, we looked into a Gekko gecko’s brain to study its internal environment and structure, using the magnetic resonance imaging (MRI technique. The results showed that the brain parenchyma was fully surrounded by the cerebrospinal fluid (CSF in the skull. A succulent characteristic was presented, which meant the intracalvarium was significantly occupied by the CSF, up to 45% in volume. Then a simplified three-dimensional finite element model was built, and a dynamic simulation was conducted to evaluate the mechanical property of this succulent characteristic during the head impactions. These implied the succulent characteristic may play certain roles on the self-protection in case of head impaction, which is adaptable to the Gekko gecko’s locomotion and behavior.

  14. Study of the Effective Parameters on the Making Use of Protective Devices

    Directory of Open Access Journals (Sweden)

    Y Tabaraie

    2012-05-01

    Full Text Available

    Background and objectives

    Noise threats health of many groups of industrial workers and causes hearing loss. Use of personal protective device is the best control method to protect against hazardous conditions. Hence, this investigation was carried out to determine situation of using of protective devices and effective parameters on it, in Qom province workers community in 2006.

     

    Methods

    This research is descriptive-sectional study. Sample volume was designed 378 persons working in factories in Qom. First of all, list of Qom factories with noise pollution problems, were collected and 30 important factories among them were selected randomly. In the second stage, 378 persons were selected randomly from workers. The interest information was obtained by questionnaire and collected data were analyzed by SPSS software.

     

    Results

    The obtained results showed that, 83.6% of workers have been using ear protective devices. 296 of them, which were using ear protective devices, had an occupational hygienist in their workplaces. This research also showed that, 109 workers that used ear protective devices, had moderate knowledge level. Moreover, 82.5% of trained workers have used ear protective devices. The statistical analysis of the results showed that there were no significant relationship between use of ear protective devices and existence of occupational hygienist in workplace, knowledge and age of workers, worker’s antecedent, physical health of workers and kind of ear protective devices (p> 0.05. 

     

    Conclusion

    These results showed that among all considered parameters; only four parameters were effective in using ear protective devices; education of workers before employment, head workman and employer’s knowledge level, factories facilitation and kind of ear protective devices.

     

  15. Surface doses under head and neck immobilisation devices

    International Nuclear Information System (INIS)

    Baveas, E.

    2004-01-01

    Full text: Methods using ion chambers, TLDs and film were developed to measure the skin-sparing properties of three head and neck immobilisation devices used in radiation therapy, viz. Sinmed multi-perforated and micro-perforated posicast thermoplastic masks (used with a supporting carbon fibre back support), and a Kablite vacuum-formed shell plastic mask (used with a Perspex back support). All measurements were performed with 6 MV beams from Elekta Precise linear accelerators. Two situations have been considered in this study. In the first situation, phantom surface doses under the flat unmoulded mask and back-support materials lying on the surface of a 'solid water' phantom were measured with parallel plate ion chambers and correlated with the physical properties of the materials. In the second situation a particular head and neck treatment technique was adopted and the treatment planned on an anthropomorphic tissue-equivalent phantom. The clinical setup consisted of a wedged pair to the right parotid, planned to deliver a reference dose of 63 Gy to the isocentre, plus an anterior supraclavicular field planned to deliver a reference dose of 50 Gy at a depth of 2 cm. The 3 immobilisation masks were each moulded to the anthropomorphic tissue-equivalent phantom. TLD chips were used to measure the phantom skin dose at a set of 18 locations under each of the 3 immobilisation masks and also without an immobilisation device. The results clearly demonstrate the extent to which the various immobilisation devices increase the surface dose. Results for the first situation are summarised. The averages of the doses recorded by the TLDs in three separate regions for the second situation are shown in Table 2. The combined results show that the areal density of the unmoulded mask materials correlates with the surface dose these materials produce before moulding, but this correlation is lost after moulding for the clinical situation considered. This change upon moulding is

  16. Pravastatin Protects Against Avascular Necrosis of Femoral Head via Autophagy.

    Science.gov (United States)

    Liao, Yun; Zhang, Ping; Yuan, Bo; Li, Ling; Bao, Shisan

    2018-01-01

    Autophagy serves as a stress response and may contribute to the pathogenesis of avascular necrosis of the femoral head induced by steroids. Statins promote angiogenesis and ameliorate endothelial functions through apoptosis inhibition and necrosis of endothelial progenitor cells, however the process used by statins to modulate autophagy in avascular necrosis of the femoral head remains unclear. This manuscript determines whether pravastatin protects against dexamethasone-induced avascular necrosis of the femoral head by activating endothelial progenitor cell autophagy. Pravastatin was observed to enhance the autophagy activity in endothelial progenitor cells, specifically by upregulating LC3-II/Beclin-1 (autophagy related proteins), and autophagosome formation in vivo and in vitro . An autophagy inhibitor, 3-MA, reduced pravastatin protection in endothelial progenitor cells exposed to dexamethasone by attenuating pravastatin-induced autophagy. Adenosine monophosphate-activated protein kinase (AMPK) is a key autophagy regulator by sensing cellular energy changes, and indirectly suppressing activation of the mammalian target of rapamycin (mTOR). We found that phosphorylation of AMPK was upregulated however phosphorylation of mTOR was downregulated in pravastatin-treated endothelial progenitor cells, which was attenuated by AMPK inhibitor compound C. Furthermore, liver kinase B1 (a phosphorylase of AMPK) knockdown eliminated pravastatin regulated autophagy protein LC3-II in endothelial progenitor cells in vitro . We therefore demonstrated pravastatin rescued endothelial progenitor cells from dexamethasone-induced autophagy dysfunction through the AMPK-mTOR signaling pathway in a liver kinase B1-dependent manner. Our results provide useful information for the development of novel therapeutics for management of glucocorticoids-induced avascular necrosis of the femoral head.

  17. Microprocessor protection devices: The present and the future

    Directory of Open Access Journals (Sweden)

    Gurevich Vladimir

    2008-01-01

    Full Text Available Paper presents the analysis of the basic constructive disadvantages of the present day microprocessor-based protective devices (MBR and offers the basic principles for creating a new MBR that can be used in newly constructed devices.

  18. Physical limitations of semiconductor devices defects, reliability and esd protection

    CERN Document Server

    Vashchenko, V A

    2008-01-01

    Provides an important link between the theoretical knowledge in the field of non-linier physics and practical application problems in microelectronics. This title focuses on power semiconductor devices and self-triggering pulsed power devices for ESD protection clamps.

  19. An application of residual current protective device at electrical installation

    International Nuclear Information System (INIS)

    Firman Silitonga

    2008-01-01

    In an electrical installation, a protection for overload and short circuit are always to be installed. In addition to the installation, it is necessary to be installed a protection device for residual current because both the short circuit and the overload device protection will not work for the residual current. The quantity of the residual current must be defined first at any electrical installation to define an appropriate residual current protection so that not every residual current will break the circuit down. This paper will explain a method how to install a residual protection device for 3500 VA or more at TN and TT of earthing system. (author)

  20. Attenuation of earmuffs used simultaneously with respiratory protective devices

    Directory of Open Access Journals (Sweden)

    Emil Kozłowski

    2017-06-01

    Full Text Available Background: In the work environment, apart from the noise, employees may be exposed to other harmful factors. Therefore, they wear hearing protectors and other personal protective equipment. The aim of the study was to determine whether simultaneous use of earmuffs and respiratory protective devices affects the attenuation of earmuffs. Material and Methods: The study was conducted in laboratory conditions using the subjective REAT (Real Ear Attenuation at Threshold and objective MIRE (Microphone in Real Ear methods. The REAT method was used to measure sound attenuation of earmuffs, while MIRE was used to determine changes in attenuation of earmuffs due to the use of other personal protective equipment. Results: The study showed reduction in attenuation of earmuffs due to the use of a full face mask up to 20 dB. Using a full face mask causes that attenuation of earmuffs in the low frequency range is close to zero. Reduction in attenuation due to the use of half masks for complete with particle filters (half masks is 3–15 dB. Simultaneous use of earmuffs and filtering half masks makes small changes in attenuation not exceeding 3 dB. Conclusions: The study showed that full face masks give the greatest reduction in attenuation of earmuffs. On the other hand, the least reduction is observed in the case of filtering half masks. There is a significant difference between the reduction in attenuation of earmuffs worn with half masks for complete with particle filters because they may be equipped with different kind of the head strap. Med Pr 2017;68(3:349–361

  1. Towards an Active Hearing Protection Device for Musicians =

    Science.gov (United States)

    Bernier, Antoine

    Professional musicians are oftentimes exposed to high levels of sound. Prolonged or severe exposure to high sound levels could lead to permanent hearing loss and compromise their career. The logical solution would be to wear hearing protection devices (HPDs) when appropriate. However, perceptual discomfort associated with wearing HPD can discourage their use by musicians. The perceptual discomfort is caused by two detrimental effects: the occlusion effect and the isolation effect. The occlusion effect is often reported as an augmented, unnatural and annoying perception of one's own voice or instrument mechanically coupled to the head when wearing HPDs. The isolation effect is the unnatural sensation of being isolated from a given sound environment and can be caused by wearing HPDs that do not compensate for psychoacoustical factors and therefore alter the wearer's auditory perception. Both effects are highly unfavorable to the musicians' auditory perception and compromise their capacity to perform to the best of their abilities for their audience. They are among the reasons most often reported by musicians to decide not to wear HPDs. This master's project presents the concept and first prototype of an active HPD for musicians that aims at solving the detrimental effects while protecting the musician's hearing. A solution for the occlusion effect is presented in the form of an earplug complemented with in-ear active noise control. Practical design issues and required trade-off are analyzed through a literature review and the implementation and characterization of an active occlusion effect reduction system, allowing reduction of the occlusion effect between 8.5 and 12 dB at 250 Hz. A solution for the isolation effect is presented in the form of an earplug complemented with digital signal processing capabilities. Factors that may cause the isolation effect are identified through a literature review and corresponding algorithms that aim at re-establishing the

  2. Well Head Protection Areas For Public Non-Community Water Supply Wells In New Jersey

    Data.gov (United States)

    U.S. Environmental Protection Agency — A Well Head Protection Area for a Public Non-Community Water Supply Well (PNCWS) in New Jersey is a map area calculated around a Public Non-Community Water Supply...

  3. Head mounted device for point-of-gaze estimation in three dimensions

    DEFF Research Database (Denmark)

    Hansen, Dan Witzner; Lidegaard, Morten; Krüger, Norbert

    2014-01-01

    This paper presents a fully calibrated extended geometric approach for gaze estimation in three dimensions (3D). The methodology is based on a geometric approach utilising a fully calibrated binocular setup constructed as a head-mounted system. The approach is based on utilisation of two ordinary...... in the horizontal and vertical dimensions regarding fixations. However, even though the workspace is limited, the fact that the system is designed as a head-mounted device, the workspace volume is relatively positioned to the pose of the device. Hence gaze can be estimated in 3D with relatively free head...

  4. 14 CFR 25.1357 - Circuit protective devices.

    Science.gov (United States)

    2010-01-01

    ... system or connected equipment. (b) The protective and control devices in the generating system must be designed to de-energize and disconnect faulty power sources and power transmission equipment from their...

  5. 14 CFR 29.1357 - Circuit protective devices.

    Science.gov (United States)

    2010-01-01

    ... faults or serious malfunction of the system or connected equipment. (b) The protective and control devices in the generating system must be designed to de-energize and disconnect faulty power sources and...

  6. Automatic coordination of protection devices in distribution system

    International Nuclear Information System (INIS)

    Comassetto, L.; Bernardon, D.P.; Canha, L.N.; Abaide, A.R.

    2008-01-01

    Among the several components of distribution systems, protection devices present a fundamental importance, since they aim at keeping the physical integrity not only of the system equipment, but also of the electricians' team and the population in general. The existing tools today in the market that carry out the making of protection studies basically draw curves, and need direct user's interference for the protection devices adjustment and coordination analyses of selectivity, being susceptible to the user's mistakes and not always considering the best technical and economical application. In Brazil, the correct application of the protection devices demand a high amount of time, being extremely laborious due to the great number of devices (around 200 devices), besides the very dynamic behaviour of distribution networks and the need for constant system expansion. This article presents a computational tool developed with the objective of automatically determining the adjustments of all protection devices in the distribution networks to obtain the best technical application, optimizing its performance and making easier protection studies. (author)

  7. New concept of microprocessor protective devices design

    Directory of Open Access Journals (Sweden)

    Gurevich Vladimir

    2010-01-01

    Full Text Available Transition from electromechanical to digital protective relays is accompanied with serious technical problems. The author offers a new approach in designing the digital relays capable of solving these problems. It is proposed to construct digital relays in the form of standard modules from which it would be possible to assemble the digital relay in the same way as now a personal computer.

  8. 30 CFR 77.401 - Stationary grinding machines; protective devices.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Stationary grinding machines; protective... OF UNDERGROUND COAL MINES Safeguards for Mechanical Equipment § 77.401 Stationary grinding machines; protective devices. (a) Stationary grinding machines other than special bit grinders shall be equipped with...

  9. 30 CFR 75.1723 - Stationary grinding machines; protective devices.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Stationary grinding machines; protective....1723 Stationary grinding machines; protective devices. (a) Stationary grinding machines other than... the wheel. (3) Safety washers. (b) Grinding wheels shall be operated within the specifications of the...

  10. Adjustable radiation protection device of the fluoroscope DG 10

    International Nuclear Information System (INIS)

    Hoermann, D.

    1980-01-01

    In cooperation with the 'VEB Transformatoren- und Roentgenwerk Hermann Matern', Dresden, an adjustable radiation protection device has been developed. This supplementary equipment for fluoroscopes ensures a sufficient protection of the gonads against undesirable X radiation, can be handled easily and does not annoy patients, esp. children

  11. Device for protecting deformations of reactor cores

    International Nuclear Information System (INIS)

    Kato, Yasuyoshi; Urushihara, Hiroshi.

    1975-01-01

    Object: To provide a fluid pressure cylinder, which is operated according to change in temperature of coolant for a reactor to restrain or release a core, to simply and effectively protect deformation of the core. Structure: A closed fluid pressure cylinder interiorly filled with suitable fluid is disposed in peripherally equally spaced relation in an annular space between a core barrel of a reactor and a reactor vessel. A piston is mounted in fluid-tight fashion in a plurality of piston openings made in the cylinder, the piston being slidably moved according to expansion and contraction of the fluid filled in the cylinder. The piston has a movable frame mounted at the foremost end thereof, the movable frame being moved integral with the piston, and the surface opposite the mount thereof biasing the outermost peripheral surface of the core. (Kamimura, M.)

  12. Overcurrent protection device for neutral beam sources

    International Nuclear Information System (INIS)

    Praeg, W.F.

    1983-01-01

    Electrical loads connected to capacitance elements in high voltage direct current systems are protected from damage caused by capacitance discharge overcurrents by connecting a longitudinal inductor between the capacitance element and the load. The inductor comprises a bifilar winding wound about a magnetic core, which forms an incomplete magnetic circuit. A diode is connected across a portion of the bifilar winding. Most of the energy discharged from the capacitance element is stored in the inductor and then dissipated, away from the load, in an L-R circuit comprising the diode and the coil winding. Multiple high voltage circuits having capacitance elements may be connected to loads through bifilar windings all wound about the aforementioned magnetic core

  13. Consumer protection issues in energy: a guide for attorneys general. Insulation, solar, automobile device, home devices

    Energy Technology Data Exchange (ETDEWEB)

    Cohen, Harry I.; Hulse, William S.; Jones, Robert R.; Langer, Robert M.; Petrucelli, Paul J.; Schroeder, Robert J.

    1979-11-01

    The guide attempts to bring together two important and current issues: energy and consumer protection. Perhaps the most basic consumer-protection issue in the energy area is assuring adequate supplies at adequate prices. It is anticipated, though, that consumers will want to consider new ways to lower enegy consumption and cost, and will thus be susceptible to fraudulent energy claims. Information is prepared on insulation, solar, energy-saving devices for the home, and energy-saving devices for the automobile.

  14. Protective device for organs exposed to medical X-radiation

    International Nuclear Information System (INIS)

    Zimmer, K.

    1978-01-01

    The protective device for male or female gonads consists of a protective screen made of hard lead coated with silicon caoutchouc, a flexible supporting arm, and a base plate on which the supporting arm for the protective screen is monted. The protective screen has got the shape of a dish resp. a pear-shaped contour for male resp. female persons. The base may be arranged on a Bucky table between the legs of the person to be examined by means of suction cups. (DG) [de

  15. Do head-restraints protect the neck from whiplash injuries?

    Science.gov (United States)

    Morris, F

    1989-01-01

    Over an 11-month period a study was made of all patients presenting to an accident and emergency department who had sustained whiplash as a result of rear-bumper impacts. The patients were analysed with respect to the presence of head-restraints in their vehicles. A significant increase in the incidence of whiplash was found in patients whose vehicles did not have head-restraints fitted. Legislation requiring all passenger cars to have head-restraints fitted as standard would have a major impact in reducing the number of whiplash injuries sustained in rear bumper impacts. PMID:2712983

  16. Intracranial pressure monitoring in severe blunt head trauma: does the type of monitoring device matter?

    Science.gov (United States)

    Aiolfi, Alberto; Khor, Desmond; Cho, Jayun; Benjamin, Elizabeth; Inaba, Kenji; Demetriades, Demetrios

    2018-03-01

    OBJECTIVE Intracranial pressure (ICP) monitoring has become the standard of care in the management of severe head trauma. Intraventricular devices (IVDs) and intraparenchymal devices (IPDs) are the 2 most commonly used techniques for ICP monitoring. Despite the widespread use of these devices, very few studies have investigated the effect of device type on outcomes. The purpose of the present study was to compare outcomes between 2 types of ICP monitoring devices in patients with isolated severe blunt head trauma. METHODS This retrospective observational study was based on the American College of Surgeons Trauma Quality Improvement Program database, which was searched for all patients with isolated severe blunt head injury who had an ICP monitor placed in the 2-year period from 2013 to 2014. Extracted variables included demographics, comorbidities, mechanisms of injury, head injury specifics (epidural, subdural, subarachnoid, intracranial hemorrhage, and diffuse axonal injury), Abbreviated Injury Scale (AIS) score for each body area, Injury Severity Score (ISS), vital signs in the emergency department, and craniectomy. Outcomes included 30-day mortality, complications, number of ventilation days, intensive care unit and hospital lengths of stay, and functional independence. RESULTS During the study period, 105,721 patients had isolated severe traumatic brain injury (head AIS score ≥ 3). Overall, an ICP monitoring device was placed in 2562 patients (2.4%): 1358 (53%) had an IVD and 1204 (47%) had an IPD. The severity of the head AIS score did not affect the type of ICP monitoring selected. There was no difference in the median ISS; ISS > 15; head AIS Score 3, 4, or 5; or the need for craniectomy between the 2 device groups. Unadjusted 30-day mortality was significantly higher in the group with IVDs (29% vs 25.5%, p = 0.046); however, stepwise logistic regression analysis showed that the type of ICP monitoring was not an independent risk factor for death

  17. Investigation of surge protective devices operation of a wind generator

    International Nuclear Information System (INIS)

    Dimitrov, D.; Vasileva, M.

    2008-01-01

    The interest to the investments in a wind energetics increases in the last years. The wind energetics is the fastest developing direction in the energetics in global scale. The wind energy is more attractive because its prices are lower in comparison of the other technologies for generating energy. The right choice of the surge protective devices has the important meaning on building and exploitation of the wind generators. The aim of this paper is investigation of the surge protective devices operation when they are installation to a wind generator. (authors)

  18. A modified face mask device for radiotherapy of head and neck tumor

    International Nuclear Information System (INIS)

    Adamietz, I.A.; Kremmin, B.; Emminger, A.

    1991-01-01

    The reproducibility during radiotherapy of head and neck tumors has been significantly improved by special devices like individual masks. However, the temporary fixation of head and neck region to the irradiation berth induces in many patients anxiety state and reduces this way the compliance. By means of modification of the device used till now a new model in which the set up mask is only coupled to the berth, could be developed. The clinical evaluation showed that this form of fixation device is much better tolerated by the patients and can be adapted without any problems to all equipment pieces in a radiotherapy department. The estimated reproducibility was comparable to that obtained with mounted device. The average translation of the central beam during 21 days observation period was 2.6±1.4 mm (0 to 9 mm) in the sagittal plane and 3.4±1.0 mm (1 to 8 mm) in the frontal plane. (orig.) [de

  19. Analysis of emboli during carotid stenting with distal protection device.

    Science.gov (United States)

    Chen, Chin-I; Iguchi, Yasuyuki; Garami, Zsolt; Malkoff, Marc D; Smalling, Richard W; Campbell, Morgan S; Alexandrov, Andrei V

    2006-01-01

    The newly developed multi-frequency transcranial Doppler (TCD) is able to differentiate gaseous from solid emboli. Our goal was to apply this technology to initially characterize emboli detected during carotid stenting with distal protection. Patients undergoing carotid angiography and stenting were monitored with 2-2.5 MHz TCD (Embo-Dop, DWL) over the middle cerebral artery unilateral to stent deployment. Sonographers insured optimal signal recordings during the procedures. Automated emboli detection and classification software (MultiXLab version 2.0) was applied for offline count and analysis. Monitoring using the Filter Wire EX (Boston Scientific) and ACCUNET system (Guidant Corporation) was performed. A total of 9,649 embolic signals were detected during 11 angiographic and 10 stenting procedures. An observer confirmed the signals using the International Consensus definition. Automated software classified these events into 5,900 gaseous and 3,749 solid emboli. During contrast injections without the protection device, 1,013 emboli were detected with 28% of these being solid. With deployment of the distal protection device, 8,636 emboli were found with 40% being solid (p protection device, 7,395 emboli with 42% solids were detected (p protection device still deployed, yielded 1,241 emboli with 31% solids (NS). Only 1 patient developed transient hemiparesthesia during ballooning that reduced the flow velocity to zero for 14 s. Neither gaseous nor solid emboli resulted in a mean flow velocity decrease or clinical symptoms. Microembolization frequently occurs during stenting even with deployment of the distal protection device. More solid emboli are seen during manipulations associated with lesion crossing. Although novel TCD methods yield a high frequency of embolic signals, further validation of this technique to determine the true nature, size, and number of emboli is needed.

  20. COMPARISON OF A HEAD MOUNTED IMPACT MEASUREMENT DEVICE TO THE HYBRID III ANTHROPOMORPHIC TESTING DEVICE IN A CONTROLLED LABORATORY SETTING.

    Science.gov (United States)

    Schussler, Eric; Stark, David; Bolte, John H; Kang, Yun Seok; Onate, James A

    2017-08-01

    Reports estimate that 1.6 to 3.8 million cases of concussion occur in sports and recreation each year in the United States. Despite continued efforts to reduce the occurrence of concussion, the rate of diagnosis continues to increase. The mechanisms of concussion are thought to involve linear and rotational head accelerations and velocities. One method of quantifying the kinematics experienced during sport participation is to place measurement devices into the athlete's helmet or directly on the athlete's head. The purpose of this research to determine the accuracy of a head mounted device for measuring the head accelerations experienced by the wearer. This will be accomplished by identifying the error in Peak Linear Acceleration (PLA), Peak Rotational Acceleration (PRA) and Peak Rotational Velocity (PRV) of the device. Laboratory study. A helmeted Hybrid III 50th percentile male headform was impacted via a pneumatic ram from the front, side, rear, front oblique and rear oblique at speeds from 1.5 to 5 m/s. The X2 Biosystems xPatch® (Seattle, WA) sensor was placed on the headform's right side at the approximate location of the mastoid process. Measures of PLA, PRA, PRV from the xPatch ® and Hybrid III were analyzed for Root Mean Square Error (RMSE), and Absolute and Relative Error (AE, RE). Seventy-six impacts were analyzed. All measures of correlation, fixed through the origin, were found to be strong: PLA R 2 =0.967 pstandard yet above the average error of testing devices in both PLA and PRA, but a low error in PRV. PLA measures from the xPatch® system demonstrated a high level of correlation with the PLA data from the Hybrid III mounted data collection system. 3.

  1. Method of and device for querying of protected structured data

    NARCIS (Netherlands)

    Jonker, Willem; Brinkman, Richard; Doumen, J.M.; Schoenmakers, Berry

    2005-01-01

    Method of and device for querying of protected data structured in the form of a tree. A corresponding tree of node polynomials is constructed such that each node polynomial evaluates to zero for an input equal to an identifier assigned to a node name occurring in a branch of the data tree starting

  2. Method of and device for querying of protected structured data

    NARCIS (Netherlands)

    Brinkman, Richard; Doumen, J.M.; Jonker, Willem; Schoenmakers, B.

    Method of and device for querying of protected data structured in the form of a tree. A corresponding tree of node polynomials is constructed such that each node polynomial evaluates to zero for an input equal to an identifier assigned to a node name occurring in a branch of the data tree starting

  3. Awareness and utilization of protective eye device among welders in ...

    African Journals Online (AJOL)

    Ramakantb

    was a high level of awareness of protective eye devices among the welders (367, 90.6%), being higher among arc welders compared ... each respondent in the field. The welders' ... Thermal retinal damage can also occur from near infrared ...

  4. Improving 200 MW NDHR reactor protection system with GAL devices

    International Nuclear Information System (INIS)

    Shi Mingde; Li Duo; Xie Zhengguo

    1999-01-01

    The emergence of General Array Logic (GAL), a fairly new type of logic devices with the characteristics of user-definable logic functions, have led to a revolutionary change in the design of logical circuits. The improvements of the reactor protection system for the 200 MW nuclear district heating reactor (NDHR) using GAL are covered

  5. Tackling the challenges of fully immersive head-mounted AR devices

    Science.gov (United States)

    Singer, Wolfgang; Hillenbrand, Matthias; Münz, Holger

    2017-11-01

    The optical requirements of fully immersive head mounted AR devices are inherently determined by the human visual system. The etendue of the visual system is large. As a consequence, the requirements for fully immersive head-mounted AR devices exceeds almost any high end optical system. Two promising solutions to achieve the large etendue and their challenges are discussed. Head-mounted augmented reality devices have been developed for decades - mostly for application within aircrafts and in combination with a heavy and bulky helmet. The established head-up displays for applications within automotive vehicles typically utilize similar techniques. Recently, there is the vision of eyeglasses with included augmentation, offering a large field of view, and being unobtrusively all-day wearable. There seems to be no simple solution to reach the functional performance requirements. Known technical solutions paths seem to be a dead-end, and some seem to offer promising perspectives, however with severe limitations. As an alternative, unobtrusively all-day wearable devices with a significantly smaller field of view are already possible.

  6. Development of automated ultrasonic device for in-service inspection of ABWR pressure vessel bottom head

    International Nuclear Information System (INIS)

    Kojima, Y.; Matsuyama, A.

    1995-01-01

    An automated device and its controller have been developed for the bottom head weld examination of pressure vessel of Advanced Boiling Water Reactor (ABWR). The internal pump casings and the housings of control rod prevent a conventional ultrasonic device from scanning the required inspection zone. With this reason, it is required to develop a new device to examine the bottom head area of ABWR. The developed device is characterized by the following features. (1) Composed of a mother vehicle and a compact inspection vehicle. They are connected only by an electric wire without using the conventional arm mechanism. (2) The mother vehicle travels on a track and lift up the inspection vehicle to the vessel. (3) The mother vehicle can automatically attach the inspection vehicle to the bottom head, and detach the inspection vehicle from it. (4) Collision avoidance control function with a touch sensor is installed at the front of the inspection vehicle. The device was successfully demonstrated using a mock-up of reactor pressure vessel

  7. Neutron protection material and neutron protection devices made of such material

    International Nuclear Information System (INIS)

    Ries, W.

    1984-01-01

    This is concerned with a neutron protection material made of thermoplastic or thermosetting plastic from high molecule hydrocarbon compounds with particularly high hydrogen and carbon contents as braking or shielding material (moderator) for fast neutrons. The plastic can contain boron for absorbing low energy neutrons. The material is used to manufacture foil, plates, pipes, shielding walls, components, bodies for radiation protection equipment, devices and plant and for neutron protection clothes. (orig./HP) [de

  8. Dependable Design Flow for Protection Systems using Programmable Logic Devices

    CERN Document Server

    Kwiatkowski, M

    2011-01-01

    Programmable Logic Devices (PLD) such as Field Programmable Gate Arrays (FPGA) are becoming more prevalent in protection and safety-related electronic systems. When employing such programmable logic devices, extra care and attention needs to be taken. The final synthesis result, used to generate the bit-stream to program the device, must be shown to meet the design’s requirements. This paper describes how to maximize confidence using techniques such as Formal Methods, exhaustive Hardware Description Language (HDL) code simulation and hardware testing. An example is given for one of the critical functions of the Safe Machine Parameters (SMP) system, used in the protection of the Large Hadron Collider (LHC) at CERN. CERN is also working towards an adaptation of the IEC- 61508 lifecycle designed for Machine Protection Systems (MPS), and the High Energy Physics environment, implementation of a protection function in FPGA code is only one small step of this lifecycle. The ultimate aim of this project is to cre...

  9. The radiation protective devices for interventional procedures using computed tomography

    International Nuclear Information System (INIS)

    Iida, Hiroji; Chabatake, Mitsuhiro; Shimizu, Mitsuru; Tamura, Sakio

    2002-01-01

    A scattered dose and a surface dose from phantom measurements during interventional procedures with computed tomography (IVR-CT) were evaluated. To reduce the personnel exposure in IVR-CT, the new protective devices were developed and its effect evaluated. Two radiation protection devices were experimentally made using a lead vinyl sheet with lead equivalent 0.125 mmPb. The first device is a lead curtain which shields the space of CT-gantry and phantom for the CT examination. The second device is a lead drape which shields on the phantom surface adjacent to the scanning plane for the CT-fluoroscopy. Scattered dose and phantom surface dose were measured with an abdominal phantom during Cine-CT (130 kV, 150 mA, 5 seconds, 10 mm section thickness). They were measured by using ionization chamber dosimeter. They were measured with and without a lead curtain and a lead drape. Scattered dose rate was measured at distance of 50-150 cm from the scanning plane. And, surface dose was measured at distance of 4-21 cm from the scanning plane on the phantom. On operator's standing position, scattered dose rates were from 8.4 to 11.6 μGy/sec at CT examination. The lead curtain and the lead drape reduced scattered dose rate at distance of 50 cm from the scanning plane by 66% and 58.3% respectively. Surface dose rate were 118 μGy/sec at distance of 5 cm from the scanning plane at CT-fluoroscopy. The lead drape reduced the surface dose by 60.5%. High scattered exposure to personnel may occur during interventional procedures using CT. They were considerably reduced during CT-arteriography by attaching the lead curtain in CT equipment. And they were substantially reduced during CT-fluoroscopy by placing the lead drape adjacent to the scanning plane, in addition, operator's hand would be protected from unnecessary radiation scattered by phantom. It was suggested that the scattered exposure to personnel could be sufficiently reduced by using radiation protection devices in IVR-CT. The

  10. Passive Cushiony Biomechanics of Head Protection in Falling Geckos

    OpenAIRE

    Wang, Hao; Wang, Wenbo; Song, Yi; Cai, Lei; Dai, Zhendong

    2018-01-01

    Gekko geckos are capable to crawl on the steep even on upside-down surfaces. Such movement, especially at great altitude, puts them at high risks of incidentally dropping down and inevitable body or head impactions, though they may trigger air-righting reaction (ARR) to attenuate the landing shocks. However, the air-righting ability (ARA) in Gekko geckos is not fully developed. The implementation of ARR in some geckos is quite slow; and for those without tails, the ARR is even unobservable. S...

  11. Device for the burst protection of nuclear reactor pressure vessels

    International Nuclear Information System (INIS)

    Daublebsky, P.

    1976-01-01

    The burst protection device has a hood over top and bottom of the pressure vessel with superimposed hinged supports lying in their turn against supporting rings which are connected with each other by vertical bracing. It is proposed to place an intermediate layer between hoods and vertical bracing absorbing thermal stresses, i.e. deforming plastically with gradually increasing pressure, but behaving like a rigid body in the case of shock loads. As a material lead e.g. is proposed. (UWI) [de

  12. Turbine protecting device in a BWR type nuclear power plant

    International Nuclear Information System (INIS)

    Kasuga, Hajime; Oka, Yoko.

    1984-01-01

    Purpose: To prevent highly humid steams from flowing into the turbine upon abnormal reduction in the reactor water level in order to ensure the turbine soundness, as well as in order to trip the turbine with no undesired effect on the reactor. Constitution: A protection device comprising a judging device and a timer are disposed in a BWR type reactor, in order to control a water level signal from a reactor water level gage. If the reactor water level is reduced during rated power operation, steams are kept to be generated due to decay heat although reactor is scramed. When a signal from the reactor water level detector is inputted to the protection device, a trip signal is outputted by way of a judging device after 15 second by means of the timer, when the main steam check valve is closed to trip the turbine. With this delay of time, abrupt increase in the pressure of the reactor due to sudden shutdown can be prevented. (Nakamoto, H)

  13. Induction and separation of motion artifacts in EEG data using a mobile phantom head device.

    Science.gov (United States)

    Oliveira, Anderson S; Schlink, Bryan R; Hairston, W David; König, Peter; Ferris, Daniel P

    2016-06-01

    Electroencephalography (EEG) can assess brain activity during whole-body motion in humans but head motion can induce artifacts that obfuscate electrocortical signals. Definitive solutions for removing motion artifact from EEG have yet to be found, so creating methods to assess signal processing routines for removing motion artifact are needed. We present a novel method for investigating the influence of head motion on EEG recordings as well as for assessing the efficacy of signal processing approaches intended to remove motion artifact. We used a phantom head device to mimic electrical properties of the human head with three controlled dipolar sources of electrical activity embedded in the phantom. We induced sinusoidal vertical motions on the phantom head using a custom-built platform and recorded EEG signals with three different acquisition systems while the head was both stationary and in varied motion conditions. Recordings showed up to 80% reductions in signal-to-noise ratio (SNR) and up to 3600% increases in the power spectrum as a function of motion amplitude and frequency. Independent component analysis (ICA) successfully isolated the three dipolar sources across all conditions and systems. There was a high correlation (r > 0.85) and marginal increase in the independent components' (ICs) power spectrum (∼15%) when comparing stationary and motion parameters. The SNR of the IC activation was 400%-700% higher in comparison to the channel data SNR, attenuating the effects of motion on SNR. Our results suggest that the phantom head and motion platform can be used to assess motion artifact removal algorithms and compare different EEG systems for motion artifact sensitivity. In addition, ICA is effective in isolating target electrocortical events and marginally improving SNR in relation to stationary recordings.

  14. Abusive head trauma and accidental head injury: a 20-year comparative study of referrals to a hospital child protection team

    Science.gov (United States)

    John, Simon; Vincent, Andrea L; Reed, Peter

    2015-01-01

    Aim To describe children referred for suspected abusive head trauma (AHT) to a hospital child protection team in Auckland, New Zealand. Methods Comparative review of demographics, histories, injuries, investigations and diagnostic outcomes for referrals under 15 years old from 1991 to 2010. Results Records were available for 345 children. Referrals increased markedly (88 in the first decade, 257 in the second), but the diagnostic ratio was stable: AHT 60%, accidental or natural 29% and uncertain cause 11%. The probability of AHT was similar regardless of socio-economic status or ethnicity. In children under 2 years old with accidental head injuries (75/255, 29%) or AHT (180/255, 71%), characteristics of particular interest for AHT included no history of trauma (88/98, 90%), no evidence of impact to the head (84/93, 90%), complex skull fractures with intracranial injury (22/28, 79%), subdural haemorrhage (160/179, 89%) and hypoxic ischaemic injury (38/39, 97%). In children over 2 years old, these characteristics did not differ significantly between children with accidental head injuries (21/47, 45%) and AHT (26/47, 55%). The mortality of AHT was higher in children over 2 years old (10/26, 38%) than under 2 years (19/180, 11%). Conclusions The striking increase in referrals for AHT probably represents increasing incidence. The decision to refer a hospitalised child with a head injury for assessment for possible AHT should not be influenced by socio-economic status or ethnicity. Children over 2 years old hospitalised for AHT are usually injured by mechanisms involving impact and should be considered at high risk of death. PMID:26130384

  15. A preliminary examination of neurocognitive performance and symptoms following a bout of soccer heading in athletes wearing protective soccer headbands.

    Science.gov (United States)

    Elbin, R J; Beatty, Amanda; Covassin, Tracey; Schatz, Philip; Hydeman, Ana; Kontos, Anthony P

    2015-01-01

    This study compared changes in neurocognitive performance and symptom reports following an acute bout of soccer heading among athletes with and without protective soccer headgear. A total of 25 participants headed a soccer ball 15 times over a 15-minute period, using a proper linear heading technique. Participants in the experimental group completed the heading exercise while wearing a protective soccer headband and controls performed the heading exercise without wearing the soccer headband. Neurocognitive performance and symptom reports were assessed before and after the acute bout of heading. Participants wearing the headband showed significant decreases on verbal memory (p = 0.02) compared with the no headband group, while the no headband group demonstrated significantly faster reaction time (p = 0.03) than the headband group following the heading exercise. These findings suggest that protective soccer headgear likely does not mitigate the subtle neurocognitive effects of acute soccer heading.

  16. Respiratory protective device design using control system techniques

    Science.gov (United States)

    Burgess, W. A.; Yankovich, D.

    1972-01-01

    The feasibility of a control system analysis approach to provide a design base for respiratory protective devices is considered. A system design approach requires that all functions and components of the system be mathematically identified in a model of the RPD. The mathematical notations describe the operation of the components as closely as possible. The individual component mathematical descriptions are then combined to describe the complete RPD. Finally, analysis of the mathematical notation by control system theory is used to derive compensating component values that force the system to operate in a stable and predictable manner.

  17. 77 FR 68717 - Updating OSHA Standards Based on National Consensus Standards; Head Protection

    Science.gov (United States)

    2012-11-16

    ..., 1918, and 1926 [Docket No. OSH-2011-0184] RIN 1218-AC65 Updating OSHA Standards Based on National Consensus Standards; Head Protection AGENCY: Occupational Safety and Health Administration (OSHA), Labor. ACTION: Proposed rule; withdrawal. SUMMARY: With this notice, OSHA is withdrawing the proposed rule that...

  18. 77 FR 68684 - Updating OSHA Standards Based on National Consensus Standards; Head Protection

    Science.gov (United States)

    2012-11-16

    ..., 1918, and 1926 [Docket No. OSHA-2011-0184] RIN 1218-AC65 Updating OSHA Standards Based on National Consensus Standards; Head Protection AGENCY: Occupational Safety and Health Administration (OSHA), Labor. ACTION: Final rule; confirmation of effective date. SUMMARY: OSHA is confirming the effective date of its...

  19. Application of head-mounted devices with eye-tracking in virtual reality therapy

    Directory of Open Access Journals (Sweden)

    Lutz Otto Hans-Martin

    2017-03-01

    Full Text Available Using eye-tracking to assess visual attention in head-mounted devices (HMD opens up many possibilities for virtual reality (VR-based therapy. Existing therapy concepts where attention plays a major role can be transferred to VR. Furthermore, they can be expanded to a precise real-time attention assessment, which can serve as a foundation for new therapy approaches. Utilizing HMDs and eye-tracking in a clinical environment is challenging because of hygiene issues and requirements of patients with heterogeneous cognitive and motor impairments. In this paper, we provide an overview of those challenges, discuss possible solutions and present preliminary results of a study with patients.

  20. Implementation of Man-made Tongue Immobilization Devices in Treating Head and Neck Cancer Patients

    Energy Technology Data Exchange (ETDEWEB)

    Baek, Jong Geal; Kim, Joo Ho; Lee, Sang Kyu; Lee, Won Joo; Yoon, Jong Won; Cho, Jeong Hee [Dept. of Radiation Oncology, Yensei Cancer Center, Yensei University Health System, Seoul (Korea, Republic of)

    2008-03-15

    For head and neck cancer patients treated with radiation therapy, proper immobilization of intra-oral structures is crucial in reproducing treatment positions and optimizing dose distribution. We produced a man-made tongue immobilization device for each patient subjected to this study. Reproducibility of treatment positions and dose distributions at air-and-tissue interface were compared using man-made tongue immobilization devices and conventional tongue-bites. Dental alginate and putty were used in producing man-made tongue immobilization devices. In order to evaluate reproducibility of treatment positions, all patients were CT-simulated, and linac-gram was repeated 5 times with each patient in the treatment position. An acrylic phantom was devised in order to evaluate safety of man-made tongue immobilization devices. Air, water, alginate and putty were placed in the phantom and dose distributions at air-and-tissue interface were calculated using Pinnacle (version 7.6c, Phillips, USA) and measured with EBT film. Two different field sizes (33 cm and 55 cm) were used for comparison. Evaluation of linac grams showed reproducibility of a treatment position was 4 times more accurate with man-made tongue immobilization devices compared with conventional tongue bites. Patients felt more comfortable using customized tongue immobilization devices during radiation treatment. Air-and-tissue interface dose distributions calculated using Pinnacle were 7.78% and 0.56% for 33 cm field and 55 cm field respectively. Dose distributions measured with EBT (international specialty products, USA) film were 36.5% and 11.8% for 33 cm field and 55 cm field respectively. Values from EBT film were higher. Using man-made tongue immobilization devices made of dental alginate and putty in treatment of head and neck cancer patients showed higher reproducibility of treatment position compared with using conventional mouth pieces. Man-made immobilization devices can help optimizing air

  1. Implementation of Man-made Tongue Immobilization Devices in Treating Head and Neck Cancer Patients

    International Nuclear Information System (INIS)

    Baek, Jong Geal; Kim, Joo Ho; Lee, Sang Kyu; Lee, Won Joo; Yoon, Jong Won; Cho, Jeong Hee

    2008-01-01

    For head and neck cancer patients treated with radiation therapy, proper immobilization of intra-oral structures is crucial in reproducing treatment positions and optimizing dose distribution. We produced a man-made tongue immobilization device for each patient subjected to this study. Reproducibility of treatment positions and dose distributions at air-and-tissue interface were compared using man-made tongue immobilization devices and conventional tongue-bites. Dental alginate and putty were used in producing man-made tongue immobilization devices. In order to evaluate reproducibility of treatment positions, all patients were CT-simulated, and linac-gram was repeated 5 times with each patient in the treatment position. An acrylic phantom was devised in order to evaluate safety of man-made tongue immobilization devices. Air, water, alginate and putty were placed in the phantom and dose distributions at air-and-tissue interface were calculated using Pinnacle (version 7.6c, Phillips, USA) and measured with EBT film. Two different field sizes (33 cm and 55 cm) were used for comparison. Evaluation of linac grams showed reproducibility of a treatment position was 4 times more accurate with man-made tongue immobilization devices compared with conventional tongue bites. Patients felt more comfortable using customized tongue immobilization devices during radiation treatment. Air-and-tissue interface dose distributions calculated using Pinnacle were 7.78% and 0.56% for 33 cm field and 55 cm field respectively. Dose distributions measured with EBT (international specialty products, USA) film were 36.5% and 11.8% for 33 cm field and 55 cm field respectively. Values from EBT film were higher. Using man-made tongue immobilization devices made of dental alginate and putty in treatment of head and neck cancer patients showed higher reproducibility of treatment position compared with using conventional mouth pieces. Man-made immobilization devices can help optimizing air

  2. Filtration of nanoparticles - Application to respiratory protecting devices

    International Nuclear Information System (INIS)

    Brochot, C.

    2012-01-01

    This study aims to determine how the respiratory protective devices (RPD), whose performances are qualified for particles above 100 nm, are effective for nanoparticles. Indeed, if the use of a collective filtration is inadequate, wearing a RPD is the last protection recommended. A literature review showed that no research concerned the effectiveness of half-masks for nanoparticles. The test bench ETNA has been sized and built to overcome these lacks. Two half masks were tested according to different configurations: constant flow rate and cyclic flow rate (average flow of 84 L /min), particle size (from 5 to 100 nm), positions of the mask (sealed, usual, or with calibrated leaks). The results show that, since the RPD contain high efficiency filter media (without charged fibers) for the most penetrating particle size (100 nm - 300 nm), the RPD is more efficient for nanoparticles. Furthermore, the results obtained in the presence of actual and calibrated leaks, highlighted the importance of face seal leakages in determining the performance of RPD. A model for calculating the protection factor was established based on the balance between the airflow through the filter and the leak. This model was validated using measurements obtained in the presence of calibrated leaks, and applied for the analysis of our results in usual position. (author)

  3. Problematic radiation protective devices for X-ray diagnostics

    International Nuclear Information System (INIS)

    Beck, A.; Nanko, N.; Bruggmoser, G.; Eble, M.

    1988-01-01

    The authors report experimental test results of radiation safety glasses with a lead equivalence of 0.5 mm Pb. The glasses were tested on a phantom, with various radiation projections, for their shielding effect with regard to the eye lens. The protective effect at AP projection was 90%, which corresponds to the data given by the manufacturer. But in most cases of interventional radiology, the examiner's eyes are exposed to lateral radiation, due to the positioning of the monitor. In these cases, reflected radiation at the side of the glasses facing the eye may induce a dose to the lens that can be fourfold the dose received without wearing the glasses, so that wearing these glasses may enhance the hazard. Another protective device tested was lead-coated gloves. The manufacturer promises a protective effect of 50% at 100 kV. The experimental test data, obtained by taking into account technical characteristics of angiographic components, confirm a radiation shielding of about 20%. (orig./HP) [de

  4. A NOVEL SUPPORT DEVICE FOR HEAD IMMOBILIZATION DURING RADIATION THERAPY THAT IS APPLICABLE TO BOTH CATS AND DOGS.

    Science.gov (United States)

    Nemoto, Yuki; Maruo, Takuya; Fukuyama, Yasuhiro; Kawarai, Shinpei; Shida, Takuo; Nakayama, Tomohiro

    2015-01-01

    Repeatable head immobilization is important for minimizing positioning error during radiation therapy for veterinary patients with head neoplasms. The purpose of this retrospective cross-sectional study was to describe a novel technique for head immobilization (Device II) and compare this technique with a previously described technique (Device I). Device II provided additional support by incorporating three teeth (vs. two teeth with Device I). Between 2011 and 2013, both devices were applied in clinically affected cats (Device I, n = 17; Device II, n = 11) and dogs (Device I, n = 85; Device II, n = 22) of various breeds and sizes. The following data were recorded for each included patient: variability in the angle of the skull (roll, yaw, and pitch), coordinates of the isocenter, and distance from the reference mark to the tumor. Devices I and II differed for skull angle variability during the treatment of dogs (roll, P = 0.0007; yaw, P = 0.0018; pitch, P = 0.0384) and for yaw of during the treatment of cats (P patients. © 2015 American College of Veterinary Radiology.

  5. Evaluation of head-free eye tracking as an input device for air traffic control.

    Science.gov (United States)

    Alonso, Roland; Causse, Mickaël; Vachon, François; Parise, Robert; Dehais, Frédéric; Terrier, Patrice

    2013-01-01

    The purpose of this study was to investigate the possibility to integrate a free head motion eye-tracking system as input device in air traffic control (ATC) activity. Sixteen participants used an eye tracker to select targets displayed on a screen as quickly and accurately as possible. We assessed the impact of the presence of visual feedback about gaze position and the method of target selection on selection performance under different difficulty levels induced by variations in target size and target-to-target separation. We tend to consider that the combined use of gaze dwell-time selection and continuous eye-gaze feedback was the best condition as it suits naturally with gaze displacement over the ATC display and free the hands of the controller, despite a small cost in terms of selection speed. In addition, target size had a greater impact on accuracy and selection time than target distance. These findings provide guidelines on possible further implementation of eye tracking in ATC everyday activity. We investigated the possibility to integrate a free head motion eye-tracking system as input device in air traffic control (ATC). We found that the combined use of gaze dwell-time selection and continuous eye-gaze feedback allowed the best performance and that target size had a greater impact on performance than target distance.

  6. Aging assessment of surge protective devices in nuclear power plants

    International Nuclear Information System (INIS)

    Davis, J.F.; Subudhi, M.; Carroll, D.P.

    1996-01-01

    An assessment was performed to determine the effects of aging on the performance and availability of surge protective devices (SPDs), used in electrical power and control systems in nuclear power plants. Although SPDs have not been classified as safety-related, they are risk-important because they can minimize the initiating event frequencies associated with loss of offsite power and reactor trips. Conversely, their failure due to age might cause some of those initiating events, e.g., through short circuit failure modes, or by allowing deterioration of the safety-related component(s) they are protecting from overvoltages, perhaps preventing a reactor trip, from an open circuit failure mode. From the data evaluated during 1980--1994, it was found that failures of surge arresters and suppressers by short circuits were neither a significant risk nor safety concern, and there were no failures of surge suppressers preventing a reactor trip. Simulations, using the ElectroMagnetic Transients Program (EMTP) were performed to determine the adequacy of high voltage surge arresters

  7. Protective head-cooling during cardiac arrest and cardiopulmonary resuscitation: the original animal studies

    Directory of Open Access Journals (Sweden)

    Eric W. Brader

    2010-02-01

    Full Text Available Prolonged standard cardiopulmonary resuscitation (CPR does not reliably sustain brain viability during cardiac arrest. Pre-hospital adjuncts to standard CPR are needed in order to improve outcomes. A preliminary dog study demonstrated that surface cooling of the head during arrest and CPR can achieve protective levels of brain hypothermia (30°C within 10 minutes. We hypothesized that protective head-cooling during cardiac arrest and CPR improves neurological outcomes. Twelve dogs under light ketamine-halothane-nitrous oxide anesthesia were arrested by transthoracic fibrillation. The treated group consisted of six dogs whose shaven heads were moistened with saline and packed in ice immediately after confirmation of ventricular fibrillation. Six control dogs remained at room temperature. All 12 dogs were subjected to four minutes of ventricular fibrillation and 20 minutes of standard CPR. Spontaneous circulation was restored with drugs and countershocks. Intensive care was provided for five hours post-arrest and the animals were observed for 24 hours. In both groups, five of the six dogs had spontaneous circulation restored. After three hours, mean neurological deficit was significantly lower in the treated group (P=0.016, with head-cooled dogs averaging 37% and the normothermic dogs 62%. Two of the six head-cooled dogs survived 24 hours with neurological deficits of 9% and 0%, respectively. None of the control group dogs survived 24 hours. We concluded that head-cooling attenuates brain injury during cardiac arrest with prolonged CPR. We review the literature related to the use of hypothermia following cardiac arrest and discuss some promising approaches for the pre-hospital setting.

  8. The protective role of carotenoids and polyphenols in patients with head and neck cancer

    Directory of Open Access Journals (Sweden)

    Hui-Ping Chang

    2015-02-01

    Full Text Available Head and neck cancer is a critical global health problem and approximately 650,000 patients per year are diagnosed with this type of cancer. In addition, head and neck cancer exhibits a high recurrence rate, readily causing second primary cancers in other locations, often yielding a poor prognosis. Current medical and surgical treatment options result in considerable impairment of speaking and swallowing functions, with side effects such as nausea, vomiting, bone marrow suppression, and renal damage, thereby impairing patients' quality of life. Thus, developing a prevention and therapeutic intervention strategy for head and neck cancer is vital. Phytochemicals have been shown to have a unique ability to protect cells from damage and modulation of cell repair. The chemopreventive activities of phytochemicals have also been demonstrated to be associated with their antioxidant properties and the induction and stimulation of intercellular communication via gap junctions, which play a role in the regulation of cancer cell cycle, differentiation, apoptosis, and stagnate cancer cell growth. Phytochemicals can also regulate cancer cell signaling pathways, reduce the invasion and metastasis of cancer cells, and protect normal cells during treatment, thus reducing the damage caused by chemotherapy and radiotherapy. The most studied of the chemopreventive effects of phytochemicals are the carotenoids and phenolics. In this review, we investigated the multiple mechanisms of carotenoids and polyphenols (PPs for use in preventing head and neck cancer, reducing the side effects of chemotherapy and radiotherapy, improving patient survival rates, and reducing the occurrence rate of second primary cancers.

  9. Automatic cell identification and visualization using digital holographic microscopy with head mounted augmented reality devices.

    Science.gov (United States)

    O'Connor, Timothy; Rawat, Siddharth; Markman, Adam; Javidi, Bahram

    2018-03-01

    We propose a compact imaging system that integrates an augmented reality head mounted device with digital holographic microscopy for automated cell identification and visualization. A shearing interferometer is used to produce holograms of biological cells, which are recorded using customized smart glasses containing an external camera. After image acquisition, segmentation is performed to isolate regions of interest containing biological cells in the field-of-view, followed by digital reconstruction of the cells, which is used to generate a three-dimensional (3D) pseudocolor optical path length profile. Morphological features are extracted from the cell's optical path length map, including mean optical path length, coefficient of variation, optical volume, projected area, projected area to optical volume ratio, cell skewness, and cell kurtosis. Classification is performed using the random forest classifier, support vector machines, and K-nearest neighbor, and the results are compared. Finally, the augmented reality device displays the cell's pseudocolor 3D rendering of its optical path length profile, extracted features, and the identified cell's type or class. The proposed system could allow a healthcare worker to quickly visualize cells using augmented reality smart glasses and extract the relevant information for rapid diagnosis. To the best of our knowledge, this is the first report on the integration of digital holographic microscopy with augmented reality devices for automated cell identification and visualization.

  10. Usefulness of the protection motivation theory in explaining hearing protection device use among male industrial workers.

    Science.gov (United States)

    Melamed, S; Rabinowitz, S; Feiner, M; Weisberg, E; Ribak, J

    1996-05-01

    The present study examined the usefulness of personal variables: noise annoyance, and components of the protection motivation theory (R. W. Rogers, 1983) along with social-organizational factors in explaining hearing protection device (HPD) use among Israeli manufacturing workers. Participants were 281 men exposed to harmful noise levels for which routine HPD use is required by regulation. In practice, 3 HPD user groups were identified: nonusers (n = 38), occasional users (n = 125), and regular users (n = 118). HPD use was objectively verified. HPD use was primarily related to the personal variables but not to management pressure, coworker pressure, or family support. The most powerful predictors of HPD use were perceived self-efficacy (for long-term HPD use), perceived susceptibility (to hearing loss), and noise annoyance, together explaining 48% of the outcome variance. These findings have implications for interventions aimed at motivating workers to use HPDs regularly.

  11. Evaluation of manufactured device for radiation therapy in head and neck cancer

    International Nuclear Information System (INIS)

    Kim, Tae Jun; Jin, Sun Sik; Kim, Dong Wook; Chung, Weon Kuu; Kim, Kyoung Tae

    2014-01-01

    We compared the set-up accuracy and right-left shoulder position variation of the manufactured device and other commercial shoulder-retractors in the head and neck radiation treatment. Six patients consist of three groups which were used three different Shoulder retractors. We measured position corrections of left and right Shoulder and the couch after the image guidance by using on board imager (OBI) for six head and neck patients who has the extended target to the neck node lower region. The position variation correction of left (right) Shoulder after image guidance were 1.07±3.99 mm (-4.35±2.09 mm), -0.37±5.91 mm (1.26±5.28 mm), -0.63±2.44 mm (0.25±1.61 mm) for group A, B and C. The vertical, lateral, longitudinal position and angular corrections of the couch after image guidance were -2.06±2.68, -1.11±8.15, 0.34±3.78 mm, and 0.51 ±0.77 degree for group A, -1.18±1.82, 0.94±2.13, -0.67±1.98 mm, and 0.91±1.04 degree for group B and 0.12±2.18, - 0.79±2.64, 0.79±2.64 mm, and 0.00±0.49 degree for group C. In this preliminary study, we found the positioning accuracy of the manufactured Shoulder retractor is comparable to other commercial Shoulder retractors. We expect that the reproducibility and accuracy of the patient set-up could be improved by using the home made Shoulder retractor in the head and neck radiation treatment

  12. Evaluation of manufactured device for radiation therapy in head and neck cancer

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae Jun; Jin, Sun Sik; Kim, Dong Wook; Chung, Weon Kuu; Kim, Kyoung Tae [Dept. of Radiation Oncology, Kyung Hee University Hospital at Gangdong, Seoul (Korea, Republic of)

    2014-06-15

    We compared the set-up accuracy and right-left shoulder position variation of the manufactured device and other commercial shoulder-retractors in the head and neck radiation treatment. Six patients consist of three groups which were used three different Shoulder retractors. We measured position corrections of left and right Shoulder and the couch after the image guidance by using on board imager (OBI) for six head and neck patients who has the extended target to the neck node lower region. The position variation correction of left (right) Shoulder after image guidance were 1.07±3.99 mm (-4.35±2.09 mm), -0.37±5.91 mm (1.26±5.28 mm), -0.63±2.44 mm (0.25±1.61 mm) for group A, B and C. The vertical, lateral, longitudinal position and angular corrections of the couch after image guidance were -2.06±2.68, -1.11±8.15, 0.34±3.78 mm, and 0.51 ±0.77 degree for group A, -1.18±1.82, 0.94±2.13, -0.67±1.98 mm, and 0.91±1.04 degree for group B and 0.12±2.18, - 0.79±2.64, 0.79±2.64 mm, and 0.00±0.49 degree for group C. In this preliminary study, we found the positioning accuracy of the manufactured Shoulder retractor is comparable to other commercial Shoulder retractors. We expect that the reproducibility and accuracy of the patient set-up could be improved by using the home made Shoulder retractor in the head and neck radiation treatment.

  13. Markerless Augmented Reality via Stereo Video See-Through Head-Mounted Display Device

    Directory of Open Access Journals (Sweden)

    Chung-Hung Hsieh

    2015-01-01

    Full Text Available Conventionally, the camera localization for augmented reality (AR relies on detecting a known pattern within the captured images. In this study, a markerless AR scheme has been designed based on a Stereo Video See-Through Head-Mounted Display (HMD device. The proposed markerless AR scheme can be utilized for medical applications such as training, telementoring, or preoperative explanation. Firstly, a virtual model for AR visualization is aligned to the target in physical space by an improved Iterative Closest Point (ICP based surface registration algorithm, with the target surface structure reconstructed by a stereo camera pair; then, a markerless AR camera localization method is designed based on the Kanade-Lucas-Tomasi (KLT feature tracking algorithm and the Random Sample Consensus (RANSAC correction algorithm. Our AR camera localization method is shown to be better than the traditional marker-based and sensor-based AR environment. The demonstration system was evaluated with a plastic dummy head and the display result is satisfactory for a multiple-view observation.

  14. Collision judgment when using an augmented-vision head-mounted display device.

    Science.gov (United States)

    Luo, Gang; Woods, Russell L; Peli, Eli

    2009-09-01

    A device was developed to provide an expanded visual field to patients with tunnel vision by superimposing minified edge images of the wide scene, in which objects appear closer to the heading direction than they really are. Experiments were conducted in a virtual environment to determine whether users would overestimate collision risks. Given simulated scenes of walking or standing with intention to walk toward a given direction (intended walking) in a shopping mall corridor, participants (12 normally sighted and 7 with tunnel vision) reported whether they would collide with obstacles appearing at different offsets from variable walking paths (or intended directions), with and without the device. The collision envelope (CE), a personal space based on perceived collision judgments, and judgment uncertainty (variability of response) were measured. When the device was used, combinations of two image scales (5x minified and 1:1) and two image types (grayscale or edge images) were tested. Image type did not significantly alter collision judgment (P > 0.7). Compared to the without-device baseline, minification did not significantly change the CE of normally sighted subjects for simulated walking (P = 0.12), but increased CE by 30% for intended walking (P 0.25). For the patients, neither CE nor uncertainty was affected by minification (P > 0.13) in both walking conditions. Baseline CE and uncertainty were greater for patients than normally sighted subjects in simulated walking (P = 0.03), but the two groups were not significantly different in all other conditions. Users did not substantially overestimate collision risk, as the x5 minified images had only limited impact on collision judgments either during walking or before starting to walk.

  15. Protective coatings for in-vessel fusion devices

    International Nuclear Information System (INIS)

    Brossa, F.

    1984-01-01

    Coatings of Al/Si, SAP (Sintered Aluminium Powder), Al 2 O 3 , TiC (low-Z material) and Ta have been developed for in-vessel component protection. Anodic oxidation, vapor depositions, reactive sputtering, chemical vapor deposition (CVD) and plasma spray have been the coating formation methods studied. AISI 316, 310, 304, Inconel 600 and Mo were adopted as base materials. the coatings were characterized in terms of composition, structure and connection with the supporting material. The behavior of coatings under H + , D + and He + irradiation in the energy range 100 eV-8 keV was tested and compared to the solid massive samples. TiC and Ta coatings were tested with thermal shock under power density pulses of 1 kW/cm 2 generated by an electron beam gun. Temperature-dependence of the erosion of TiC by vacuum arcs in a magnetic field was also studied. TiC coatings have low sputtering values, good resistance to arcing and a high chemical stability. TiC and Ta, CVD and plasma spray coatings are thermal-shock resistant. High thermal loads produce cracks but no spalling. Destruction occurred only after melting of the base material. The plasma spray coating method seems to be most appropriate for developing remote handling applications in fusion devices. (orig.)

  16. Staging workers' use of hearing protection devices: application of the transtheoretical model.

    Science.gov (United States)

    Raymond, Delbert M; Lusk, Sally L

    2006-04-01

    The threat of noise-induced hearing loss is a serious concern for many workers. This study explores use of the transtheoretical model as a framework for defining stages of workers' acceptance of hearing protection devices. A secondary analysis was performed using a cross-section of data from a randomized, controlled clinical trial of an intervention to increase use of hearing protection. Use of hearing protection devices was well distributed across the theorized stages of change. Chi-square analysis and analysis of variance revealed significant differences between stages for the variables studied. Discrete stages of hearing protection device use can be identified, laying the foundation for further work investigating use of the transtheoretical model for promoting hearing protection device use. The model can provide a framework for tailoring interventions and evaluating their effects. With further development of the transtheoretical model, nurses may be able to easily identify workers' readiness to use hearing protection devices and tailor training toward that goal.

  17. Use of mobile device technology to continuously collect patient-reported symptoms during radiation therapy for head and neck cancer: A prospective feasibility study

    Directory of Open Access Journals (Sweden)

    Aaron D. Falchook, MD

    2016-04-01

    Conclusions: A substantial percentage of patients used mobile devices to continuously report symptoms throughout a course of radiation therapy for head and neck cancer. Future studies should evaluate the impact of mobile device symptom reporting on improving patient outcomes.

  18. Efficiency and safety of percuSurge distal protection device in acute ...

    African Journals Online (AJOL)

    user

    2011-04-25

    Apr 25, 2011 ... myocardial infarction. The long-term effects of the distal protection device are still in controversy. The enhanced myocardial efficacy and recovery by aspiration of liberated debris (EMERALD) trial failed to show the effectiveness of the distal protection device in patients with AMI (Yamada and Topol, 2000).

  19. Safeguards of basic protection devices, high-protection devices, full-protection devices and school X-ray devices. Guideline for manufacturer and evaluating experts, rev. 1.0; Sicherheitsvorrichtungen von Basisschutzgeraeten, Hochschutzgeraeten, Vollschutzgeraeten und Schulroentgeneinrichtungen. Anforderungen fuer die Bauartpruefung nach der Roentgenverordnung. Leitfaden fuer Hersteller und Gutachter Rev. 1.0

    Energy Technology Data Exchange (ETDEWEB)

    Dombrowski, Harald; Grottker, Ulrich; Pullner, Bjoern; Roettger, Annette; Zwiener, Roland

    2017-07-15

    This report describes the PTB requirements for engineered safeguards of basic-protection devices, high-protection devices, full-protection devices and school X-ray devices within the framework of type tests according to the German X-ray Ordinance. It contains detailed requirements for the hard- and software to ensure the required safety level. Especially manufacturers and evaluators of such X-ray tube assemblies are addressed.

  20. Distal protection filter device efficacy with carotid artery stenting: comparison between a distal protection filter and a distal protection balloon.

    Science.gov (United States)

    Iko, Minoru; Tsutsumi, Masanori; Aikawa, Hiroshi; Matsumoto, Yoshihisa; Go, Yoshinori; Nii, Kouhei; Abe, Gorou; Ye, Iwae; Nomoto, Yasuyuki; Kazekawa, Kiyoshi

    2013-01-01

    This retrospective study aimed to compare the effectiveness of the embolization prevention mechanism of two types of embolic protection device (EPD)-a distal protection balloon (DPB) and a distal protection filter (DPF). Subjects were 164 patients scheduled to undergo carotid artery stenting: a DPB was used in 82 cases (DPB group) from April 2007 until June 2010, and a DPF was used in 82 cases (DPF group) from July 2010 to July 2011. Rates of positive findings on postoperative diffusion-weighted imaging (DWI) and stroke incidence were compared. Positive postoperative DWI results were found in 34 cases in the DPB group (41.4 %), but in only 22 cases in the DPF group (26.8 %), and there was only a small significant difference within the DPF group. In the DPB group, there was one case of transient ischemic attack (TIA) (1.2 %) and four cases of brain infarction (2 minor strokes, 2 major strokes; 4.9 %), compared to the DFP group with one case of TIA (1.2 %) and no cases of minor or major strokes. In this study, significantly lower rates of occurrence of DWI ischemic lesions and intraoperative embolization were associated with use of the DPF compared to the DPB.

  1. Protective effect of amifostine on dental health after radiotherapy of the head and neck

    International Nuclear Information System (INIS)

    Rudat, Volker; Meyer, Jens; Momm, Felix; Bendel, Martin; Henke, Michael; Strnad, Vratislav; Groetz, Knut; Schulte, Andreas

    2000-01-01

    Purpose: The cytoprotective agent amifostine has been shown to reduce the radiation-induced acute and chronic xerostomia in head and neck cancer patients. The purpose of this study was to evaluate whether or not amifostine also reduces the incidence of dental caries associated with the radiation-induced xerostomia. Methods and Materials: The dental status before and 1 year after radiotherapy was retrospectively compared in 35 unselected patients treated as part of the prospective randomized and multicenter open-label Phase III study (WR-38) at the University Hospitals of Heidelberg, Freiburg, and Erlangen. The WR-38 study compared radiotherapy in head and neck cancer with and without concomitant administration of amifostine. Results: Patient and treatment characteristics (particularly the radiation dose and percentage of parotids included in the treatment volume) were equally distributed between the patients who received (n = 17) or did not receive (n = 18) amifostine. Fifteen patients of the amifostine group showed no deterioration of the dental status 1 year after radiotherapy as compared to 7 patients who did not receive the cytoprotector (p = 0.015, two-tailed Fisher exact test). Conclusion: Our data suggest a protective effect of amifostine on the dental health after radiotherapy of the head and neck. The dental status should be used as a primary endpoint in future studies on amifostine.

  2. Injuries of the head from backface deformation of ballistic protective helmets under ballistic impact.

    Science.gov (United States)

    Rafaels, Karin A; Cutcliffe, Hattie C; Salzar, Robert S; Davis, Martin; Boggess, Brian; Bush, Bryan; Harris, Robert; Rountree, Mark Steve; Sanderson, Ellory; Campman, Steven; Koch, Spencer; Dale Bass, Cameron R

    2015-01-01

    Modern ballistic helmets defeat penetrating bullets by energy transfer from the projectile to the helmet, producing helmet deformation. This deformation may cause severe injuries without completely perforating the helmet, termed "behind armor blunt trauma" (BABT). As helmets become lighter, the likelihood of larger helmet backface deformation under ballistic impact increases. To characterize the potential for BABT, seven postmortem human head/neck specimens wearing a ballistic protective helmet were exposed to nonperforating impact, using a 9 mm, full metal jacket, 124 grain bullet with velocities of 400-460 m/s. An increasing trend of injury severity was observed, ranging from simple linear fractures to combinations of linear and depressed fractures. Overall, the ability to identify skull fractures resulting from BABT can be used in forensic investigations. Our results demonstrate a high risk of skull fracture due to BABT and necessitate the prevention of BABT as a design factor in future generations of protective gear. © 2014 American Academy of Forensic Sciences.

  3. 30 CFR 77.600 - Trailing cables; short-circuit protection; disconnecting devices.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Trailing cables; short-circuit protection... AREAS OF UNDERGROUND COAL MINES Trailing Cables § 77.600 Trailing cables; short-circuit protection; disconnecting devices. Short-circuit protection for trailing cables shall be provided by an automatic circuit...

  4. The use of hearing protection devices by older adults during recreational noise exposure.

    Science.gov (United States)

    Nondahl, D M; Cruickshanks, K J; Dalton, D S; Klein, B E K; Klein, R; Tweed, T S; Wiley, T L

    2006-01-01

    A population-based study to assess the use of hearing protection devices by older adults during noisy recreational activities was performed. The population-based Epidemiology of Hearing Loss Study was designed to measure the prevalence of hearing loss in adults residing in Beaver Dam, Wisconsin. The use of hearing protection devices during noisy recreational activities was assessed by performing three examinations over a period of 10 years (1993-1995, no. of participants (n)=3753, aged 48-92 years; 1998-2000, n=2800, aged 53-97 years; 2003-2005, n=2395, aged 58-100 years). The recreational activities included hunting, target shooting, woodworking/carpentry, metalworking, driving loud recreational vehicles, and performing yard work using either power tools or a chain saw. The prevalence of using hearing protection devices during any of these activities increased with time (9.5%, 15.0%, and 19.9% at baseline, 5 years, and 10 years, respectively). However, the use of hearing protection devices remained low for most activities. Those under the age of 65 were twice as likely to use hearing protection devices during noisy activities than were older adults. Men, those with a hearing handicap, and those with significant tinnitus were more likely to use hearing protection devices. Smokers and the less educated were less likely to use hearing protection devices. The results demonstrated that many adults expose themselves to potentially damaging recreational noise, leaving them at risk for hearing loss.

  5. Graphene in NLO Devices for High Laser Energy Protection

    Science.gov (United States)

    2010-10-01

    manufacturing graphene in > tonlyr quantities suitable for industrial applications, has been working to advance the application base ofgJ1lphene. We have...Transfer A suspension of graphene in toluene was sent to the Army’s Tank- Automotive Research, Development, and Engineering Center (TARDEC) for evaluation in...protection efficiency. Therefore, a critical component for evaluation and use of graphene suspensions for laser protection is dispersion of the graphene

  6. Using Protection Layers for a 2-Photon Water Splitting Device

    DEFF Research Database (Denmark)

    Seger, Brian; Mei, Bastian Timo; Frydendal, Rasmus

    2015-01-01

    The 2-photon tandem device for photocatalytic water splitting has been theoretically shown to provide a higher efficiency than a single photon device(1). This increased efficiency can be achieved by having one material optimized to absorb high energy photons (large bandgap) and another material...... optimized to absorb low energy photons (small bandgap). To a large degree this approach has been hindered by corrosion issues. In this talk I will first discuss how our computational screening of 2,400 materials showed that very few materials can efficiently absorb light without corroding in water splitting...

  7. Awareness training and hearing protection devices: Current practices in the South African mining industry

    CSIR Research Space (South Africa)

    Edwards, A

    2012-09-01

    Full Text Available This presentation outlines the importance of awareness training of managers at all levels and miners regarding the importance of hearing protection devices and adequate knowledge, motivation and training to prevent hearing loss....

  8. Research and development to protect soldiers from landmines and improvised explosive devices

    CSIR Research Space (South Africa)

    Ahmed, R

    2015-10-01

    Full Text Available Landmines and Improvised Explosive Devices (IEDs) remain a major threat for military vehicles, their occupants and other assets. It is thus imperative that traditional methods of protection need to be adapted or new technologies developed....

  9. Clothing, equipment and devices for personnel protection: Its selection according to occupational risks

    International Nuclear Information System (INIS)

    1989-01-01

    This Venezuelan standard establishes the selection of the type of clothing, equipment and devices for personnel protection, to be used by workers according to the occupational risk they deal with, in order to avoid or to reduce the factors that can, directly or indirectly, affect their physical integrity. For the risks not contemplated in this norm, the selection of the type of clothing, equipment and devices for personnel protection, must be done following the corresponding international standard [es

  10. Effects of Active and Passive Hearing Protection Devices on Sound Source Localization, Speech Recognition, and Tone Detection.

    Directory of Open Access Journals (Sweden)

    Andrew D Brown

    Full Text Available Hearing protection devices (HPDs such as earplugs offer to mitigate noise exposure and reduce the incidence of hearing loss among persons frequently exposed to intense sound. However, distortions of spatial acoustic information and reduced audibility of low-intensity sounds caused by many existing HPDs can make their use untenable in high-risk (e.g., military or law enforcement environments where auditory situational awareness is imperative. Here we assessed (1 sound source localization accuracy using a head-turning paradigm, (2 speech-in-noise recognition using a modified version of the QuickSIN test, and (3 tone detection thresholds using a two-alternative forced-choice task. Subjects were 10 young normal-hearing males. Four different HPDs were tested (two active, two passive, including two new and previously untested devices. Relative to unoccluded (control performance, all tested HPDs significantly degraded performance across tasks, although one active HPD slightly improved high-frequency tone detection thresholds and did not degrade speech recognition. Behavioral data were examined with respect to head-related transfer functions measured using a binaural manikin with and without tested HPDs in place. Data reinforce previous reports that HPDs significantly compromise a variety of auditory perceptual facilities, particularly sound localization due to distortions of high-frequency spectral cues that are important for the avoidance of front-back confusions.

  11. Examination of the protective roles of helmet/faceshield and directionality for human head under blast waves.

    Science.gov (United States)

    Sarvghad-Moghaddam, Hesam; Jazi, Mehdi Salimi; Rezaei, Asghar; Karami, Ghodrat; Ziejewski, Mariusz

    2015-01-01

    A parametric study was conducted to delineate the efficacy of personal protective equipment (PPE), such as ballistic faceshields and advanced combat helmets, in the case of a blast. The propagations of blast waves and their interactions with an unprotected head, a helmeted one, and a fully protected finite element head model (FEHM) were modeled. The biomechanical parameters of the brain were recorded when the FEHM was exposed to shockwaves from the front, back, top, and bottom. The directional dependent tissue response of the brain and the variable efficiency of PPE with respect to the blast orientation were two major results of this study.

  12. Evaluating Tree Protection Devices: Effects on Growth and Survival–First-Year Results

    Science.gov (United States)

    L. R. Costello; R. H. Schmidt; Gregory A. Giusti

    1991-01-01

    The protection of seedlings from animal browsing is critical for the survival and growth of many tree species. This is particularly true in wildland areas and arid areas (McAuliffe, 1986), and oftentimes in urban areas. A variety of techniques and devices have been used to protect seedlings, from using straw stubble to milk cartons to plastic or metal screens. Recently...

  13. Intercomparison of radiation protection protection devices in a high-energy stray neutron field. Part III: Instrument response

    Czech Academy of Sciences Publication Activity Database

    Silari, M.; Agosteo, S.; Beck, P.; Bedogni, R.; Cale, E.; Caresana, M.; Domingo, C.; Donadille, L.; Dubourg, N.; Esposito, A.; Fehrenbacher, G.; Fernández, F.; Ferrarini, M.; Fiechtner, A.; Fuchs, A.; García, M. J.; Golnik, N.; Gutermuth, F.; Khurana, S.; Klages, T.; Latocha, M.; Mares, V.; Mayer, S.; Radon, T.; Reithmeier, H.; Rollet, S.; Roos, H.; Rühm, W.; Sandri, S.; Schardt, D.; Simmer, G.; Spurný, František; Trompier, F.; Villa-Grasa, C.; Weitzenegger, E.; Wiegel, B.; Wielunski, M.; Wissmann, F.; Zechner, A.; Zielczyński, M.

    2009-01-01

    Roč. 44, 7-8 (2009), s. 673-691 ISSN 1350-4487 R&D Projects: GA AV ČR IAA100480902 Institutional research plan: CEZ:AV0Z10480505 Keywords : radiation protection devices * radiation field * detectors * dosemeters Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 0.973, year: 2009

  14. Platelet-Rich Plasma in the Treatment of Subcutaneous Venous Access Device Scars: A Head-to-Head Patient Survey

    Directory of Open Access Journals (Sweden)

    C. Eichler

    2015-01-01

    Full Text Available Introduction. Platelet-rich plasma (PRP is a product widely used in sports medicine, tissue repair, and general surgery. A recent meta-analysis showed this product to be beneficial when introduced into a wound area, be it intra-articular (i.e., joint-injections or direct introduction onto the wound surface. Methods. Between the years of 2012 and 2014 a questionnaire evaluating surgical outcome after port (venous access device removal was answered by 100 patients in the control group and 20 patients in a PRP group, leading to a total of 120 patients in this single center, retrospective, subjective outcome evaluation. Results. No statistical difference was shown in postsurgical complication rates, postsurgical pain, decreased mobility, and overall quality of life. A significant difference was shown in overall patient satisfaction and the desire to further improve port area scarring. Results differed significantly in favor of the PRP group. Interestingly, approximately 40.2% of patients are dissatisfied with the surgical outcome after port removal in the control group. This result, though surprising, may be improved to 10% dissatisfaction when a PRP product is used. Conclusion. PRP products such as Arthrex ACP are safe to use and present an additional option in improving surgical outcome.

  15. Implementation of Transformer Protection by Intelligent Electronic Device for Different Faults

    OpenAIRE

    Y V Aruna, Beena S

    2015-01-01

    Protection of power system equipments was traditionally done by using electromagnetic relay, static relays, and numerical relays. At present the microprocessor based relays are replacing the old Electromagnetic relays because of their high level accuracy and fast operation. RET670(Transformer protection relay ), an IED (INTELLIGENT ELECTRONIC DEVICE) provides fast and selective protection, monitoring, and control of all types of transformer. The configured IED is tested under diff...

  16. Corrosion and corrosion protection of support structures for offshore wind energy devices (OWEA)

    Energy Technology Data Exchange (ETDEWEB)

    Momber, A. [Muehlhan AG, Schlinckstrasse 3, D-21107 Hamburg (Germany)

    2011-05-15

    The paper provides a review about the corrosion and corrosion protection of offshore wind energy devices (OWEA). Firstly, special features resulting from location and operation of OWEA are being discussed. Secondly, types of corrosion and corrosion phenomena are summarized in a systematic way. Finally, practical solutions to the corrosion protection of OWEA, including steel allowances, cathodic protection and coatings and linings, are discussed. (Copyright copyright 2011 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  17. A Study on the technology of the Protective Device Application for the power Telecommunication Facilities

    Energy Technology Data Exchange (ETDEWEB)

    Lee, B.K.; Lee, S.J.; Choi, H.Y. [Korea Electric Power Research Insitute, Taejeon (Korea, Republic of); Lee, B.H.; Jeon, D.K.; Lee, K.O.; Ahn, C.H.; Kim, S.O.; Kim, J.S. [Electrical Engineering and Science Research Center, Seoul (Korea, Republic of)

    1997-12-31

    In order to protect the power telecommunication system from surge by lightning or switching and ground potential rise, characteristics of surge are analyzed when surge strikes communication system. Surge generator which meets international standard was made and test of protective devices was carried out by using it. Counter measures against surge is established through the analysis of ground potential which varies with transient ground impedance. Also specification for installing protective devices was recommended, which is proper to apply to the field system. (author). 186 refs., 203 figs., 21 tabs.

  18. Parent Perceptions of Mobile Device Use Among Preschool-Aged Children in Rural Head Start Centers.

    Science.gov (United States)

    McCloskey, Morgan; Johnson, Susan L; Benz, Cristen; Thompson, Darcy A; Chamberlin, Barbara; Clark, Lauren; Bellows, Laura L

    2018-01-01

    To describe child use and parents' beliefs and comfort with young children's use of mobile devices in low-income, rural communities. This was a descriptive, cross-sectional study. The survey, which consisted of 18 multiple-part questions, was distributed to families at 5 Head Start/preschool centers in Colorado. In total, 192 surveys were returned (28.5% response rate). Most children (92%) used a smartphone or tablet at some frequency and most parents (90%) had downloaded apps specifically for their child. Education and ethnicity were related to parents' technology beliefs. Parent comfort with technology was positively associated with greater child use of technology (P Mobile device use was relatively high in this sample. Mobile devices appear to be a feasible platform to offer nutrition and physical activity education for this audience. Ensuring parent comfort with technology and apps will be important. Copyright © 2017 Society for Nutrition Education and Behavior. Published by Elsevier Inc. All rights reserved.

  19. Protection against head injuries should not be optional: a case for mandatory installation of side-curtain air bags.

    Science.gov (United States)

    Stuke, Lance E; Nirula, Raminder; Gentilello, Larry M; Shafi, Shahid

    2010-10-01

    More than 9,000 vehicle occupants die each year in side-impact vehicle collisions, primarily from head injuries. The authors hypothesized that side-curtain air bags significantly improve head and neck safety in side-impact crash testing. Side-impact crash-test data were obtained from the Insurance Institute for Highway Safety, which ranks occupant protection as good, acceptable, marginal, or poor. Vehicles of the same make and model that underwent side-impact crash testing both with and without side-curtain air bags were compared, as well as the protective effect of these air bags on occupants' risk for head and neck injury. Of all the passenger vehicles, 25 models have undergone side-impact crash testing with and without side-curtain air bags by the Insurance Institute for Highway Safety. Only 3 models without side-curtain air bags (12%) provided good head and neck protection for drivers, while 21 cars with side-curtain air bags (84%) provided good protection (P bags was less dramatic but significant (84% without vs 100% with side-curtain air bags, P = .04). Side-curtain air bags significantly improve vehicle occupant safety in side-impact crash tests. Installation of these air bags should be federally mandated in all passenger vehicles. Copyright © 2010 Elsevier Inc. All rights reserved.

  20. PLZT thermal/flash protective goggles: device concepts and constraints

    International Nuclear Information System (INIS)

    Cutchen, J.T.

    1979-01-01

    In 1975 Sandia Laboratories began the design and development of PLZT Goggles for the US Air Force to provide protection from temporary flashblindness and permanent retinal burns caused by the brilliant flash of nuclear explosions. The user requirements, system and physical constraints, and use/storage environments were all considered in arriving at the final design goals. When the program began, there was no industrial capability to manufacture large-aperture PLZT materials or bonded lens assemblies. The technology has been established from a laboratory baseline in a brief period, and operational testing and evaluation by the Air Force has been completed. The goggles, identified as the EEU-2/P,, are now in production

  1. An overcurrent protection device for neutral beam sources

    International Nuclear Information System (INIS)

    Praeg, W.F.

    1983-01-01

    Electrical loads connected to capacitance elements in high voltage direct current systems are protected from damage caused by capacitance discharge overcurrents by connecting a longitudinal inductor between the capacitance element and the load. The inductor comprises a bifilar winding wound about a magnetic core, which forms an incomplete magnetic circuit. A diode is connected across a portion of the bifilar winding. Most of the energy discharged from the capacitance element is stored in the inductor and then dissipated, away from the load, in an L-R circuit comprising the diode and the coil winding. Multiple high voltage circuits having capacitance elements may be connected to loads through bifilar windings all wound about the aforementioned magnetic core

  2. Comparison of Video Head Impulse Test (vHIT) Gains Between Two Commercially Available Devices and by Different Gain Analytical Methods.

    Science.gov (United States)

    Lee, Sang Hun; Yoo, Myung Hoon; Park, Jun Woo; Kang, Byung Chul; Yang, Chan Joo; Kang, Woo Suk; Ahn, Joong Ho; Chung, Jong Woo; Park, Hong Ju

    2018-06-01

    To evaluate whether video head impulse test (vHIT) gains are dependent on the measuring device and method of analysis. Prospective study. vHIT was performed in 25 healthy subjects using two devices simultaneously. vHIT gains were compared between these instruments and using five different methods of comparing position and velocity gains during head movement intervals. The two devices produced different vHIT gain results with the same method of analysis. There were also significant differences in the vHIT gains measured using different analytical methods. The gain analytic method that compares the areas under the velocity curve (AUC) of the head and eye movements during head movements showed lower vHIT gains than a method that compared the peak velocities of the head and eye movements. The former method produced the vHIT gain with the smallest standard deviation among the five procedures tested in this study. vHIT gains differ in normal subjects depending on the device and method of analysis used, suggesting that it is advisable for each device to have its own normal values. Gain calculations that compare the AUC of the head and eye movements during the head movements show the smallest variance.

  3. New supporting and protecting device for nuclear boilers

    International Nuclear Information System (INIS)

    Pierart, Robert.

    1980-01-01

    A rigid supporting device is described. It is intended for permanently connected equipment such as a nuclear reactor vessel and its steam generators. It consists of a double thick metal plate structure, the two parts of which are rigidly fixed together: 1/ The lower part is provided with a central body enveloping and supporting the vessel by means of pivots welded to it. These pivots are adjusted and slide in bearings integrated into the above mentioned structure, which is double skinned by an external body enveloping at least partially the water boxes of the steam generators and supporting the steam generators by adjusted pivots sliding in bearings integrated into this external body. The bottom parts of the central and external bodies are welded onto a thick metallic base. 2/ The upper part is partitioned by vertical extensions of the central body in such a way as to form a discharging reservoir in its central part. Lateral bodies on both sides envelope the steam generator tube bundles. The upper part of these lateral bodies are connected together by casings which act as stiffeners [fr

  4. Preventive protection device and method for bottom of reactor pressure vessel

    International Nuclear Information System (INIS)

    Hayashi, Eisaku; Kurosawa, Koichi; Furukawa, Hideyasu; Morinaka, Ren; Enomoto, Kunio; Otaka, Masahiro; Yoshikubo, Fujio; Chiba, Noboru; Sato, Kazunori.

    1995-01-01

    In a preventive protection device for improving stresses in reactor structural components by jetting highly pressurized water with cavitation bubbles from a jetting nozzle toward structural components in a reactor pressure vessel, a fixed structure to a CRD housing is provided with a rotational body attached to the structure, a multi joint arm and a jetting nozzle supported to the multi joint arm. The jetting nozzle is disposed at a position where the center of the jetting deviates from the center of the CRD housing. In addition, a monitoring camera is disposed for displaying the target for preventive protection. The state of stresses on a plurality of targets for preventive protection can be improved by the preventive protection device at a fixed position in the bottom of a reactor pressure vessel where housings stand densely, thereby enabling to attain the preventive protection operation easily and rapidly. (N.H.)

  5. Protection relay of phase-shifting device with thyristor switch for high voltage power transmission lines

    Science.gov (United States)

    Lachugin, V. F.; Panfilov, D. I.; Akhmetov, I. M.; Astashev, M. G.; Shevelev, A. V.

    2014-12-01

    Problems of functioning of differential current protection systems of phase shifting devices (PSD) with mechanically changed coefficient of transformation of shunt transformer are analyzed. Requirements for devices of protection of PSD with thyristor switch are formulated. Based on use of nonlinear models of series-wound and shunt transformers of PSD modes of operation of major protection during PSD, switching to zero load operation and to operation under load and during short circuit operation were studied for testing PSD with failures. Use of the principle of duplicating by devices of differential current protection (with realization of functions of breaking) of failures of separate pares of PSD with thyristor switch was substantiated. To ensure protection sensitivity to the shunt transformer winding short circuit, in particular, to a short circuit that is not implemented in the current differential protection for PSD with mechanical switch, the differential current protection reacting to the amount of primary ampere-turns of high-voltage and low-voltage winding of this transformer was designed. Studies have shown that the use of differential current cutoff instead of overcurrent protection for the shunt transformer wndings allows one to provide the sensitivity during thyristor failure with the formation of a short circuit. The results of simulation mode for the PSD with switch thyristor designed to be installed as switching point of Voskhod-Tatarskaya-Barabinsk 220 kV transmission line point out the efficiency of the developed solutions that ensure reliable functioning of the PSD.

  6. Novel material and structural design for large-scale marine protective devices

    International Nuclear Information System (INIS)

    Qiu, Ang; Lin, Wei; Ma, Yong; Zhao, Chengbi; Tang, Youhong

    2015-01-01

    Highlights: • Large-scale protective devices with different structural designs have been optimized. • Large-scale protective devices with novel material designs have been optimized. • Protective devices constructed of sandwich panels have the best anti-collision performance. • Protective devices with novel material design can reduce weight and construction cost. - Abstract: Large-scale protective devices must endure the impact of severe forces, large structural deformation, the increased stress and strain rate effects, and multiple coupling effects. In evaluation of the safety of conceptual design through simulation, several key parameters considered in this research are maximum impact force, energy dissipated by the impactor (e.g. a ship) and energy absorbed by the device and the impactor stroke. During impact, the main function of the ring beam structure is to resist and buffer the impact force between ship and bridge pile caps, which could guarantee that the magnitude of impact force meets the corresponding requirements. The means of improving anti-collision performance can be to increase the strength of the beam section or to exchange the steel material with novel fiber reinforced polymer laminates. The main function of the buoyancy tank is to absorb and transfer the ship’s kinetic energy through large plastic deformation, damage, or friction occurring within itself. The energy absorption effect can be improved by structure optimization or by the use of new sandwich panels. Structural and material optimization schemes are proposed on the basis of conceptual design in this research, and protective devices constructed of sandwich panels prove to have the best anti-collision performance

  7. Study of efficiency and current use of respiratory protective devices

    International Nuclear Information System (INIS)

    Linauskas, S.H.; Kalos, F.

    1984-12-01

    The efficiency of a helmet-type powered air-purifying respirator was studied in the work environment of an underground uranium mine. Workplace protection factors (WPF) were measured, using approximately 30-minute air sampling periods and repeated sampling throughout the work shifts for six miners during three shifts each. The WPF of the modified Racal AH-5 helmet was 17.8 (geometric mean) with new filters in the respirator; the WPF dropped to 5.3 when four-day-old filters were used. The WPF results were lognormally distributed. The test population appeared to be a homogeneous set: there was no significant difference in the mean WPFs of individual test subjects. The study could not resolve any effect of elapsed time within the work shift or of ambient Working Level on the WPF. The actual use levels and the problems associated with respirator use were studied at the same time, principally via a user survey. The respirators have a high level of acceptance among the user population of underground uranium miners and 72.5 percent of the 207 survey respondents stated six or more hours use with the visor in the correct 'down' position per shift

  8. A NOVEL, REMOVABLE, CERROBEND, BEAM-BLOCKING DEVICE FOR RADIATION THERAPY OF THE CANINE HEAD AND NECK: PILOT STUDY.

    Science.gov (United States)

    Kent, Michael S; Berlato, Davide; Vanhaezebrouck, Isabelle; Gordon, Ira K; Hansen, Katherine S; Theon, Alain P; Holt, Randall W; Trestrail, Earl A

    2017-01-01

    Radiation therapy of the head and neck can result in mucositis and other acute affects in the oral cavity. This prospective pilot study evaluated a novel, intraoral, beam-blocking device for use during imaging and therapeutic procedures. The beam-blocking device was made from a metal alloy inserted into a coated frozen dessert mold (Popsicle® Mold, Cost Plus World Market, Oakland, CA). The device was designed so that it could be inserted into an outer shell, which in turn allowed it to be placed or removed depending on the need due to beam configuration. A Farmer type ionization chamber and virtual water phantom were used to assess effects of field size on transmission. Six large breed cadaver dogs, donated by the owner after death, were recruited for the study. Delivered dose at the dorsal and ventral surfaces of the device, with and without the alloy block in place, were measured using radiochromic film. It was determined that transmission was field size dependent with larger field sizes leading to decreased attenuation of the beam, likely secondary to scatter. The mean and median transmission on the ventral surface without the beam-blocking device was 0.94 [range 0.94-0.96]. The mean and median transmission with the beam-blocking device was 0.52 [range 0.50-0.57]. The mean and median increase in dose due to backscatter on the dorsal surface of the beam-blocking device was 0.04 [range 0.02-0.04]. Findings indicated that this novel device can help attenuate radiation dose ventral to the block in dogs, with minimal backscatter. © 2016 American College of Veterinary Radiology.

  9. Surge protective device response to steep front transient in low voltage circuit

    Energy Technology Data Exchange (ETDEWEB)

    Marcuz, J.; Binczak, S.; Bilbault, J.M. [Universite de Bourgogne, Dijon (France)], Emails: jerome.marcuz@ laposte.net, stbinc@u-bourgogne.fr, bilbault@u-bourgogne.fr; Girard, F. [ADEE Electronic, Pont de Pany (France)

    2007-07-01

    Surge propagation on cables of electrical or data lines leads to a major protection problem as the number of equipment based on solid-state circuits or microprocessors increases. Sub-microsecond components of real surge waveform has to be taken into account for a proper protection even in the case of surges caused by indirect lightning effects. The response of a model of transient voltage suppressor diode based surge protection device (SPD) to fast front transient is analytically studied, then compared to simulations, including the lines connected to the SPD and to the protected equipment. (author)

  10. The Protective Effect of Cordycepin On Alcohol-Induced Osteonecrosis of the Femoral Head

    Directory of Open Access Journals (Sweden)

    Yi-Xuan Chen

    2017-08-01

    Full Text Available Background: Alcohol abuse is known to be a leading risk factor for atraumatic osteonecrosis of the femoral head (ONFH, in which the suppression of osteogenesis plays a critical role. Cordycepin benefits bone metabolism; however, there has been no study to determine its effect on osteonecrosis. Methods: Human bone mesenchymal stem cells (hBMSCs were identified by multi-lineage differentiation. Alkaline phosphatase (ALP activity, RT-PCR, western blots, immunofluorescent assay and Alizarin red staining of BMSCs were evaluated. A rat model of alcohol-induced ONFH was established to investigate the protective role of cordycepin against ethanol. Hematoxylin & eosin (H&E staining and micro-computerized tomography (micro-CT were performed to observe ONFH. Apoptosis was assessed by TdT-mediated dUTP nick end labeling (TUNEL. Immunohistochemical staining was carried out to detect OCN and COL1. Results: Ethanol significantly suppressed ALP activity, decreased gene expression of OCN and BMP2, lowered levels of RUNX2 protein, and reduced immunofluorescence staining of OCN and COL1 and calcium formation of hBMSCs. However, these inhibitory effects were attenuated by cordycepin co-treatment at concentrations of 1 and 10 µg/mL Moreover, it was revealed that the osteo-protective effect of cordycepin was associated with modulation of the Wnt/β-catenin pathway. In vivo, by micro-CT, TUNEL and immunohistochemical staining of OCN and COL1, we found that cordycepin administration prevented alcohol-induced ONFH. Conclusion: Cordycepin treatment to enhance osteogenesis may be considered a potential therapeutic approach to prevent the development of alcohol-induced ONFH.

  11. Smart Electrochemical Energy Storage Devices with Self-Protection and Self-Adaptation Abilities.

    Science.gov (United States)

    Yang, Yun; Yu, Dandan; Wang, Hua; Guo, Lin

    2017-12-01

    Currently, with booming development and worldwide usage of rechargeable electrochemical energy storage devices, their safety issues, operation stability, service life, and user experience are garnering special attention. Smart and intelligent energy storage devices with self-protection and self-adaptation abilities aiming to address these challenges are being developed with great urgency. In this Progress Report, we highlight recent achievements in the field of smart energy storage systems that could early-detect incoming internal short circuits and self-protect against thermal runaway. Moreover, intelligent devices that are able to take actions and self-adapt in response to external mechanical disruption or deformation, i.e., exhibiting self-healing or shape-memory behaviors, are discussed. Finally, insights into the future development of smart rechargeable energy storage devices are provided. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Estimation of digital protection devices applicability on basis of multiple characterizing parameters

    Directory of Open Access Journals (Sweden)

    Dimitar Bogdanov

    2018-01-01

    Full Text Available The contemporary electrical power systems (EPS impose increased requirements for the functionality of the protection systems. The necessity of improved EPS stability is in some extent resulting of the increased integration of renewable sources of electrical energy. The future grid development gives perspective for connection of more converter based generations. The power electronic schemes and associated functional requirements impose necessity of high speed, sensitive, selective and reliable operation of the protection devices. These requirements have always been target of the protection equipment producers and grid operators. The electronic converting schemes specifics impose these requirements for the protection devices in more straightened way, as the converter connected generator may need to trip in shorter time than classical machine generator. In the article is presented a generalized overview of some of the characteristics of the digital “relay” protection devices, and approach for device selection is proposed. Investment planning may utilize such approach in order to have an optimal design from financial point of view.

  13. Electronic Systems for the Protection of Superconducting Devices in the LHC

    CERN Document Server

    Denz, R; Mess, K H

    2008-01-01

    The Large Hadron Collider LHC [1] incorporates an unprecedented amount of superconducting components: magnets, bus-bars, and current leads. Most of them require active protection in case of a transition from the superconducting to the resistive state, the so-called quench. The electronic systems ensuring the reliable quench detection and further protection of these devices have been developed and produced over the last years and are currently being put into operation

  14. Nonconformance in electromechanical output relays of microprocessor-based protection devices under actual operating conditions

    OpenAIRE

    Gurevich, Vladimir

    2006-01-01

    Microprocessor-based protection relays are gradually driving out traditional electromechanical and even electronic protection devices from virtually all fields of power and electrical engineering. In this paper, one of many problems of microprocessor-based relays is discussed: nonconformance of miniature electromechanical output relays under actual operation conditions: switching inductive loads (with tripping CB coils or lockout relay coils) at 220 VDC, and "dry" switching of some control ci...

  15. Evaluation of novel disposable, light-weight radiation protection devices in an interventional radiology setting: a randomized controlled trial.

    Science.gov (United States)

    Uthoff, Heiko; Peña, Constantino; West, James; Contreras, Francisco; Benenati, James F; Katzen, Barry T

    2013-04-01

    Radiation exposure to interventionalists is increasing. The currently available standard radiation protection devices are heavy and do not protect the head of the operator. The aim of this study was to evaluate the effectiveness and comfort of caps and thyroid collars made of a disposable, light-weight, lead-free material (XPF) for occupational radiation protection in a clinical setting. Up to two interventional operators were randomized to wear a XPF or standard 0.5-mm lead-equivalent thyroid collars in 60 consecutive endovascular procedures requiring fluoroscopy. Simultaneously a XPF cap was worn by all operators. Radiation doses were measured using dosimeters placed outside and underneath the caps and thyroid collars. Wearing comfort was assessed at the end of each procedure on a visual analog scale (0-100 [100 = optimal]). Patient and procedure data did not differ between the XPF and standard protection groups. The cumulative radiation dose measured outside the cap was 15,700 μSv and outside the thyroid collars 21,240 μSv. Measured radiation attenuation provided by the XPF caps (n = 70), XPF thyroid collars (n = 40), and standard thyroid collars (n = 38) was 85.4% ± 25.6%, 79.7% ± 25.8% and 71.9% ± 34.2%, respectively (mean difference XPF vs standard thyroid collars, 7.8% [95% CI, -5.9% to 21.6%]; p = 0.258). The median XPF cap weight was 144 g (interquartile range, 128-170 g), and the XPF thyroid collars were 27% lighter than the standard thyroid collars (p disposable caps and thyroid collars made of XPF were assessed as being comfortable to wear, and they provide radiation protection similar to that of standard 0.5-mm lead-equivalent thyroid collars.

  16. Gender and other factors associated with the use of hearing protection devices at work

    Directory of Open Access Journals (Sweden)

    Tatiane Costa Meira

    2015-01-01

    Full Text Available OBJECTIVE To analyze whether sociodemographic, occupational, and health-related data are associated with the use of hearing protection devices at work, according to gender.METHODS A cross-sectional study was conducted in 2006, using a random sample of 2,429 workers, aged between 18 and 65 years old, from residential sub-areas in Salvador, BA, Northeastern Brazil. Questionnaires were used to obtain sociodemographic, occupational, and health-related data. Workers who reported that they worked in places where they needed to shout in order to be heard were considered to be exposed to noise. Exposed workers were asked whether they used hearing protection devices, and if so, how frequently. Analyses were conducted according to gender, with estimates made about prevalence of the use of hearing protection devices, prevalence ratios, and their respective 95% confidence intervals.RESULTS Twelve percent (12.3% of study subjects reported that they were exposed to noise while working. Prevalence of the use of hearing protection devices was 59.3% for men and 21.4% for women. Men from higher socioeconomic levels (PR = 1.47; 95%CI 1.14;1.90 and who had previous audiometric tests (PR = 1.47; 95%CI 1.15;1.88 were more likely to use hearing protection devices. For women, greater perceived safety was associated with the use of protection devices (PR = 2.92; 95%CI 1.34;6.34. This perception was specifically related to the presence of supervisors committed to safety (PR = 2.09; 95%CI 1.04;4.21, the existence of clear rules to prevent workplace injuries (PR = 2.81; 95%CI 1.41;5.59, and whether they were informed about workplace safety (PR = 2.42; 95%CI 1.23;4.76.CONCLUSIONS There is a gender bias regarding the use of hearing protection devices that is less favorable to women. The use of such devices among women is positively influenced by their perception of a safe workplace, suggesting that gender should be considered as a factor in hearing conservation programs.

  17. Head Impact Laboratory (HIL)

    Data.gov (United States)

    Federal Laboratory Consortium — The HIL uses testing devices to evaluate vehicle interior energy attenuating (EA) technologies for mitigating head injuries resulting from head impacts during mine/...

  18. Identification, investigation and analysis of end-of-wind protection devices for vertical and incline shafts.

    CSIR Research Space (South Africa)

    Ottermann, RW

    2000-12-01

    Full Text Available The occurrence and cause of overwind and underwind events in underground mining were investigated in conjunction with devices, which are at present being applied to prevent and control such incidents. Proposals for in-shaft systems to protect...

  19. Effects of Hearing Protection Device Attenuation on Unmanned Aerial Vehicle (UAV) Audio Signatures

    Science.gov (United States)

    2016-03-01

    UAV ) Audio Signatures by Melissa Bezandry, Adrienne Raglin, and John Noble Approved for public release; distribution...Research Laboratory Effects of Hearing Protection Device Attenuation on Unmanned Aerial Vehicle ( UAV ) Audio Signatures by Melissa Bezandry...Aerial Vehicle ( UAV ) Audio Signatures 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) Melissa Bezandry

  20. Three-dimensional biomimetic head model as a platform for thermal testing of protective goggles for prevention of eye injuries.

    Science.gov (United States)

    Friedman, Rinat; Haimy, Ayelet; Gefen, Amit; Epstein, Yoram

    2018-04-22

    The rate of eye injury is steadily rising during military conflicts of the century, with thermal burns being the most common type of injury to the eyes. The present study focuses on assessing the heat resistance properties of military protective goggles using three-dimensional (3D) finite element head modeling fitted with the tested protective gear. A computational thermal impact was applied onto a 3D biomimetic human head model fitted with two goggle models - sports (Type 1) and square (Type 2). The resultant temperature of the eye tissues and the thermal injury thresholds were calculated by using the modeling, hence allowing to determine the protective efficacy of the goggles objectively, in a standardized, quantitative and cost-effective manner. Both types of goggles had a dramatic protective effect on the eyes. The specific goggle geometry had no notable effect on the level of protection to the inner tissues against the thermal insult. At the skin level goggles reduced temperatures by ~64% under the impact zone, with only a mild difference (10 °C) between the goggles. Little limitations on the shape and geometry of goggles were observed and any structure of goggles can provide an adequate protection against a thermal insult (per se) to inner cranial tissues, assuming the lenses are wide and thick enough to block direct skin contact of the heat insult. It was shown that our 3D biomimetic human head model provides a practical and cost-effective tool for determining the performance level of goggles with different attributed (i.e., shapes and thermal properties). Copyright © 2018 Elsevier Ltd. All rights reserved.

  1. Retinal artery occlusion during carotid artery stenting with distal embolic protection device.

    Science.gov (United States)

    Kohara, Kotaro; Ishikawa, Tatsuya; Kobayashi, Tomonori; Kawamata, Takakazu

    2018-01-01

    Retinal artery occlusion associated with carotid artery stenosis is well known. Although it can also occur at the time of carotid artery stenting, retinal artery occlusion via the collateral circulation of the external carotid artery is rare. We encountered two cases of retinal artery occlusion that were thought to be caused by an embolus from the external carotid artery during carotid artery stenting with a distal embolic protection device for the internal carotid artery. A 71-year-old man presented with central retinal artery occlusion after carotid artery stenting using the Carotid Guardwire PS and a 77-year-old man presented with branch retinal artery occlusion after carotid artery stenting using the FilterWire EZ. Because additional new cerebral ischaemic lesions were not detected in either case by postoperative diffusion-weighted magnetic resonance imaging, it was highly likely that the debris that caused retinal artery occlusion passed through not the internal carotid artery but collaterals to retinal arteries from the external carotid artery, which was not protected by a distal embolic protection device. It is suggested that a distal protection device for the internal carotid artery alone cannot prevent retinal artery embolisation during carotid artery stenting and protection of the external carotid artery is important to avoid retinal artery occlusion.

  2. Tests of microprocessor-based relay protection devices: Problems and solutions

    Directory of Open Access Journals (Sweden)

    Gurevich Vladimir

    2009-01-01

    Full Text Available Usually, the operational condition of relay protection devices is checked with specific settings used for the relay operation in a certain network point. In the author's opinion in order to verify the proper operation of complex multifunctional microprocessor-based protection devices (MPD at their inspection, start-up after repairs or during periodic tests there is no need to use the actual settings at which the relay is to be operated in a certain network's point. It should be tested for proper operation at several of its most critical preset characteristic points as well as in several preset characteristics constituting its most complicated (combined operation modes, including the dynamic operation modes with preset transition processes specific for standard power networks (not necessarily for a specific point. The proposed set of actions for the unification of software platforms of the modern, microprocessor-based relay protection test systems will enable examination of modern MPD in an absolutely new way. .

  3. A study on ship impacting a flexible crashworthy device for protecting bridge pier

    Directory of Open Access Journals (Sweden)

    Yang Liming

    2015-01-01

    Full Text Available As the accident of a vessel impacting a bridge pier will cause serious disaster, such as destroyed bridge, sinking ship and polluting environment, the technology and method to protect bridge pier from ship collision have been widely investigated recently. Due to the huge kinetic energy of large-tonnage ship and the short time duration in the collision, the studies involve impact mechanics. A developed flexible crashworthy device has been developed to protect bridges, which consists of an outer steel-periphery, an inner steel-periphery and the rubber coating SWRCs(soft elements installed between them. When the SWRC crashworthy device is installed, the collision duration under low impact force is prolonged due to its high compliance, which results in the ship having enough time to turn its navigation direction and most of the remainder kinetic energy being carried off by the turned away ship. Consequently, both impact forces on the ship and on the bridge pier decrease markedly. This is the key reason as to why the SWRC crashworthy device can avoid the destruction of both the bridge and the ship. Based on our results of theoretical studies and numerical simulations, the present paper will propose an experiment-adopted a real ship to impact a flexible crashworthy device. The collision test has been performed 12 times with different speed, carrying capacity, and impact angle of the ship. After the experiments, the ship, flexible crashworthy device and the pier are not damaged. The experiments show that the flexible crashworthy device can turn away the impact ship, so that the ship moves along the outer part of the device, which reduces the ship impact force on the bridge pier obviously. It not only protects bridges but also avoids the damage to ships.

  4. Evaluation of the positional accuracy and dosimetric properties of a three-dimensional printed device for head and neck immobilization

    International Nuclear Information System (INIS)

    Sato, Kiyokazu; Yanagawa, Isao; Takeda, Ken; Dobashi, Suguru; Kadoya, Noriyuki; Ito, Kengo; Chiba, Mizuki; Jingu, Keiichi; Kishi, Kazuma

    2017-01-01

    Our aim was to investigate the feasibility of a three-dimensional (3D)-printed head-and-neck (HN) immobilization device by comparing its positional accuracy and dosimetric properties with those of a conventional immobilization device (CID). We prepared a 3D-printed immobilization device (3DID) consisting of a mask and headrest with acrylonitrile-butadiene-styrene resin developed from the computed tomography data obtained by imaging a HN phantom. For comparison, a CID comprising a thermoplastic mask and headrest was prepared using the same HN phantom. We measured the setup error using the ExacTrac X-ray image system. Furthermore, using the ionization chamber and the water-equivalent phantom, we measured the changes in the dose due to the difference in the immobilization device material from the photon of 4 MV and 6 MV. The positional accuracy of the two devices were almost similar in each direction except in the vertical, lateral, and pitch directions (t-test, p<0.0001), and the maximum difference was 1 mm, and 1deg. The standard deviations were not statistically different in each direction except in the longitudinal (F-test, p=0.034) and roll directions (F-test, p<0.0001). When the thickness was the same, the dose difference was almost similar at a 50 mm depth. At a 1 mm depth, the 3DID-plate had a 2.9-4.2% lower dose than the CID-plate. This study suggested that the positional accuracy and dosimetric properties of 3DID were almost similar to those of CID. (author)

  5. Web software for the control and management of radiation protection devices in the Cadarache site

    International Nuclear Information System (INIS)

    Beltritti, F.

    2010-01-01

    This series of slides presents how to use a new software dedicated to the management of the periodical controls that have to be performed on the equipment involved in radiation protection. This software is ready to be dispatched on the CEA site of Cadarache. This software gives information on: the device to be controlled, the controls that have to be performed, the procedures to follow to make the test, the equipment necessary for the test particularly the need for radioactive sources, the maintenance of the device, the previous measurements and in the end the device's conformity. An evaluation of the conformity of all the devices present in a building or an area or of a particular type can be easily obtained. (A.C.)

  6. Usability testing of an mHealth device for swallowing therapy in head and neck cancer survivors.

    Science.gov (United States)

    Constantinescu, Gabriela; Kuffel, Kristina; King, Ben; Hodgetts, William; Rieger, Jana

    2018-04-01

    The objective of this study was to conduct the first patient usability testing of a mobile health (mHealth) system for in-home swallowing therapy. Five participants with a history of head and neck cancer evaluated the mHealth system. After completing an in-application (app) tutorial with the clinician, participants were asked to independently complete five tasks: pair the device to the smartphone, place the device correctly, exercise, interpret progress displays, and close the system. Quantitative and qualitative methods were used to evaluate the effectiveness, efficiency, and satisfaction with the system. Critical changes to the app were found in three of the tasks, resulting in recommendations for the next iteration. These issues were related to ease of Bluetooth pairing, placement of device, and interpretation of statistics. Usability testing with patients identified issues that were essential to address prior to implementing the mHealth system in subsequent clinical trials. Of the usability methods used, video observation (synced screen capture with videoed gestures) revealed the most information.

  7. MODELING OF POWER SYSTEMS AND TESTING OF RELAY PROTECTION DEVICES IN REAL AND MODEL TIME

    Directory of Open Access Journals (Sweden)

    I. V. Novash

    2017-01-01

    Full Text Available The methods of modelling of power system modes and of testing of relay protection devices with the aid the simulation complexes in real time and with the help of computer software systems that enables the simulation of virtual time scale are considered. Information input protection signals in the simulation of the virtual model time are being obtained in the computational experiment, whereas the tests of protective devices are carried out with the help of hardware and software test systems with the use of estimated input signals. Study of power system stability when modes of generating and consuming electrical equipment and conditions of devices of relay protection are being changed requires testing with the use of digital simulators in a mode of a closed loop. Herewith feedbacks between a model of the power system operating in a real time and external devices or their models must be determined (modelled. Modelling in real time and the analysis of international experience in the use of digital simulation power systems for real-time simulation (RTDS simulator have been fulfilled. Examples are given of the use of RTDS systems by foreign energy companies to test relay protection systems and control, to test the equipment and devices of automatic control, analysis of cyber security and evaluation of the operation of energy systems under different scenarios of occurrence of emergency situations. Some quantitative data on the distribution of RTDS in different countries and Russia are presented. It is noted that the leading energy universities of Russia use the real-time simulation not only to solve scientific and technical problems, but also to conduct training and laboratory classes on modelling of electric networks and anti-emergency automatic equipment with the students. In order to check serviceability of devices of relay protection without taking into account the reaction of the power system tests can be performed in an open loop mode with the

  8. Shielding of the child's head during x-ray studies

    International Nuclear Information System (INIS)

    Tolmach, Eh.U.

    1985-01-01

    Three devices for X-ray shielding of child's head are suggested; the first one is a protective attachment for shielding a child being in horizontal position on an X-ray table; the second one is a protective stand for shielding head and body at roentgenofraphy of upper extremities of a child sitting near the X-ray table; the third one is a prot ctive suspension for shielding the head of a child being in vertical position

  9. Privacy Protection for Personal Health Device Communication and Healthcare Building Applications

    Directory of Open Access Journals (Sweden)

    Soon Seok Kim

    2014-01-01

    Full Text Available This paper proposes a new method for protecting patient privacy when communicating with a gateway which collects bioinformation through using personal health devices, a type of biosensor for telemedicine, at home and in other buildings. As the suggested method is designed to conform with ISO/IEEE 11073-20601, which is the international standard, interoperability with various health devices was considered. We believe it will be a highly valuable resource for dealing with basic data because it suggests an additional standard for security with the Continua Health Alliance or related international groups in the future.

  10. An externally head-mounted wireless neural recording device for laboratory animal research and possible human clinical use.

    Science.gov (United States)

    Yin, Ming; Li, Hao; Bull, Christopher; Borton, David A; Aceros, Juan; Larson, Lawrence; Nurmikko, Arto V

    2013-01-01

    In this paper we present a new type of head-mounted wireless neural recording device in a highly compact package, dedicated for untethered laboratory animal research and designed for future mobile human clinical use. The device, which takes its input from an array of intracortical microelectrode arrays (MEA) has ninety-seven broadband parallel neural recording channels and was integrated on to two custom designed printed circuit boards. These house several low power, custom integrated circuits, including a preamplifier ASIC, a controller ASIC, plus two SAR ADCs, a 3-axis accelerometer, a 48MHz clock source, and a Manchester encoder. Another ultralow power RF chip supports an OOK transmitter with the center frequency tunable from 3GHz to 4GHz, mounted on a separate low loss dielectric board together with a 3V LDO, with output fed to a UWB chip antenna. The IC boards were interconnected and packaged in a polyether ether ketone (PEEK) enclosure which is compatible with both animal and human use (e.g. sterilizable). The entire system consumes 17mA from a 1.2Ahr 3.6V Li-SOCl2 1/2AA battery, which operates the device for more than 2 days. The overall system includes a custom RF receiver electronics which are designed to directly interface with any number of commercial (or custom) neural signal processors for multi-channel broadband neural recording. Bench-top measurements and in vivo testing of the device in rhesus macaques are presented to demonstrate the performance of the wireless neural interface.

  11. FiberNet--a new embolic protection device for carotid artery stenting.

    Science.gov (United States)

    Bauer, C; Franke, J; Bertog, S C; Woerner, V; Ghasemzadeh-Asl, S; Sievert, H

    2014-05-01

    Though distal filter protection during carotid stenting reduces the risk of cerebrovascular events, periprocedural stroke remains a risk despite their broad usage. This observation may be related to the pore size of common filters. The FiberNet distal filter system is unique by its very small pore size (40 µm) as well as its low profile and flexibility. Little data is available regarding the clinical performance and safety of this device. The aim was the evaluation of the safety of the FiberNet embolic protection system during carotid artery stenting. All consecutive patients treated with carotid stenting at our institution using the FiberNet device were systematically followed. Primary endpoint was the rate of all death and stroke within 30 days of the procedure. Carotid artery stenting using the FiberNet embolic protection system was performed in 54 patients. The procedure was technical successful in all patients. Three patients (5.5%) had a TIA. Amauosis fugax occurred in two patients (3.7%). One patient (1.9%) had a minor stroke with hemiparesis of the left arm and face which resolved completely within 48 hr after the procedure. No patient died or suffered a major stroke. The safety and feasibility of the FiberNet distal protection system appears to be at least equivalent to that reported in studies using conventional distal filter protection. Copyright © 2013 Wiley Periodicals, Inc.

  12. [The organizational projects management led by head nurses: qualitative study from an educational device.

    Science.gov (United States)

    Dujardin, Pierre-Philippe; Reverdy, Thomas; Valette, Annick; François, Patrice

    2017-09-01

    The work of operational coordination led by head nurses (HN) is more known than their abilities to change work organization, as well as, care practices. In this article, we explore organizational projects led by HN. Depending on the situations, they may concern their health care team or involve institutional hierarchy or other teams. We rely on an intervention study, which enabled us to follow 17 organizational projects led by HN for one year. The results of this study highlight as the main condition for success, the HN' efforts to enable mutual understanding with other interested actors. Managers, who engage their health care team in the development of solutions, bring sustainable results. When problems involve the hierarchy, the managers focus on the development of personal relationships. When problems involve other departments, which they depend on, then they engage themselves into integrative negotiations. These results invite to open discussion about work organization and to formalize organizational projects. This intervention study also points out that work - training at operational audit is relevant for HN. Activé par Editorial Manager® et ProduXion.

  13. The solar ultraviolet B radiation protection provided by shading devices with regard to its diffuse component.

    Science.gov (United States)

    Kudish, Avraham I; Harari, Marco; Evseev, Efim G

    2011-10-01

    The composition of the incident solar global ultraviolet B (UVB) radiation with regard to its beam and diffuse radiation fractions is highly relevant with regard to outdoor sun protection. This is especially true with respect to sun protection during leisure-time outdoor sun exposure at the shore and pools, where people tend to escape the sun under shade trees or different types of shading devices, e.g., umbrellas, overhangs, etc., believing they offer protection from the erythemal solar radiation. The degree of sun protection offered by such devices is directly related to the composition of the solar global UVB radiation, i.e., its beam and diffuse fractions. The composition of the incident solar global UVB radiation can be determined by measuring the global UVB (using Solar Light Co. Inc., Model 501A UV-Biometer) and either of its components. The beam component of the UVB radiation was determined by measuring the normal incidence beam radiation using a prototype, tracking instrument consisting of a Solar Light Co. Inc. Model 501A UV-Biometer mounted on an Eppley Solar Tracker Model St-1. The horizontal beam component of the global UVB radiation was calculated from the measured normal incidence using a simple geometric correlation and the diffuse component is determined as the difference between global and horizontal beam radiations. Horizontal and vertical surfaces positioned under a horizontal overhang/sunshade or an umbrella are not fully protected from exposure to solar global UVB radiation. They can receive a significant fraction of the UVB radiation, depending on their location beneath the shading device, the umbrella radius and the albedo (reflectance) of the surrounding ground surface in the case of a vertical surface. Shading devices such as an umbrella or horizontal overhang/shade provide relief from the solar global radiation and do block the solar global UVB radiation to some extent; nevertheless, a significant fraction of the solar global UVB

  14. Plasma sprayed TiC coatings for first wall protection in fusion devices

    International Nuclear Information System (INIS)

    Groot, P.; Laan, J.G. van der; Laas, L.; Mack, M.; Dvorak, M.

    1989-01-01

    For protection of plasma facing components in nuclear fusion devices thick titanium carbide coatings are being developed. Coatings have been produced by plasma spraying at atmospheric pressure (APS) and low pressure (LPPS) and analyzed with respect to microstructure and chemical composition. Thermo-mechanical evaluation has been performed by applying short pulse laser heat flux tests. The influence of coating thickness and porosity on the resistance to spalling by thermal shocks appears to be more important than aspects of chemical composition. (author)

  15. Balance between Privacy Protecting and Selling User Data of Wearable Devices

    OpenAIRE

    Huang, Kuang-Chiu; Hsu, Jung-Fang

    2017-01-01

    Smart bracelets are capable of identifying individual data, which can synchronize the step count, mileage, calorie consumption, heart rate, sleeping data and even the pictures users uploaded with the APP. This feature is so convenient on one hand but makes us lose control of our privacy on the other hand. With poor privacy protection mechanism embedded in these wearable devices that hackers can easily invade and steal user data. In addition, most smart bracelet companies have not made a clear...

  16. Shivering heat production and body fat protect the core from cooling during body immersion, but not during head submersion: a structural equation model.

    Science.gov (United States)

    Pretorius, Thea; Lix, Lisa; Giesbrecht, Gordon

    2011-03-01

    Previous studies showed that core cooling rates are similar when only the head or only the body is cooled. Structural equation modeling was used on data from two cold water studies involving body-only, or whole body (including head) cooling. Exposure of both the body and head increased core cooling, while only body cooling elicited shivering. Body fat attenuates shivering and core cooling. It is postulated that this protection occurs mainly during body cooling where fat acts as insulation against cold. This explains why head cooling increases surface heat loss with only 11% while increasing core cooling by 39%. Copyright © 2011 Elsevier Ltd. All rights reserved.

  17. Acceptability of the Predicting Abusive Head Trauma (PredAHT) clinical prediction tool: A qualitative study with child protection professionals.

    Science.gov (United States)

    Cowley, Laura E; Maguire, Sabine; Farewell, Daniel M; Quinn-Scoggins, Harriet D; Flynn, Matthew O; Kemp, Alison M

    2018-05-09

    The validated Predicting Abusive Head Trauma (PredAHT) tool estimates the probability of abusive head trauma (AHT) based on combinations of six clinical features: head/neck bruising; apnea; seizures; rib/long-bone fractures; retinal hemorrhages. We aimed to determine the acceptability of PredAHT to child protection professionals. We conducted qualitative semi-structured interviews with 56 participants: clinicians (25), child protection social workers (10), legal practitioners (9, including 4 judges), police officers (8), and pathologists (4), purposively sampled across southwest United Kingdom. Interviews were recorded, transcribed and imported into NVivo for thematic analysis (38% double-coded). We explored participants' evaluations of PredAHT, their opinions about the optimal way to present the calculated probabilities, and their interpretation of probabilities in the context of suspected AHT. Clinicians, child protection social workers and police thought PredAHT would be beneficial as an objective adjunct to their professional judgment, to give them greater confidence in their decisions. Lawyers and pathologists appreciated its value for prompting multidisciplinary investigations, but were uncertain of its usefulness in court. Perceived disadvantages included: possible over-reliance and false reassurance from a low score. Interpretations regarding which percentages equate to 'low', 'medium' or 'high' likelihood of AHT varied; participants preferred a precise % probability over these general terms. Participants would use PredAHT with provisos: if they received multi-agency training to define accepted risk thresholds for consistent interpretation; with knowledge of its development; if it was accepted by colleagues. PredAHT may therefore increase professionals' confidence in their decision-making when investigating suspected AHT, but may be of less value in court. Copyright © 2018 Elsevier Ltd. All rights reserved.

  18. Fish protection at steam-electric power plants: alternative screening devices

    International Nuclear Information System (INIS)

    Cannon, J.B.

    1978-01-01

    Since the enactment of the Federal Water Pollution Control Act Amendments of 1972, very few innovations have surfaced that advance the state of intake technology for fish protection at steam-electric power plants. After careful examination of basic hydrology, hydraulics, and ecology of the source water body is completed and after a suitable location for the intake is established, the design process reduces to the development of proper screening techniques and to the provision of a means of preventing resident and migratory species from entering the intake structure. As a result of this design process, three basic fish protection concepts have evolved: fish deterrence, fish collection and removal, and fish diversion. Intake screening devices that protect fish are discussed

  19. Cerebral protection devices for use during carotid artery angioplasty with stenting: a health technology assessment.

    Science.gov (United States)

    Menon, Devidas; Stafinski, Tania

    2006-01-01

    This study sought to examine the safety, efficacy, and economic implications of the use of cerebral protection devices during carotid artery angioplasty and stenting (CAS) in high-risk patients with severe carotid artery disease (CAD). A comprehensive search for peer- and non-peer-reviewed studies that compared carotid endarterectomy (CEA) or CAS without cerebral protection to CAS with cerebral protection and appeared in the English language literature between January 1990 and January 2005 was completed. Information from studies identified was extracted using a common data abstraction form and then critically appraised against published quality assessment criteria. Of the eight studies found, six provided information on technical or procedural success rates, with values ranging from 95.6 percent to 100 percent. Three of the four studies comparing groups of patients who received CAS with cerebral protection with those who received only CAS reported a non-statistically significantly higher 30-day incidence of death and stroke (major or minor) in the latter group. None of the three studies comparing CAS with cerebral protection to CEA demonstrated a statistically significant difference in the 30-day incidence of death, major stroke, or myocardial infarction between treatment groups. No economic analyses were found. In high-risk patients with severe CAD, the evidence suggests that CAS with cerebral protection may offer a safe and efficacious alternative to CEA, reducing the risk of embolic peri-procedural complications associated with CAS to acceptable levels.

  20. Fish-protection devices at unscreened water diversions can reduce entrainment: evidence from behavioural laboratory investigations

    Science.gov (United States)

    Poletto, Jamilynn B.; Cocherell, Dennis E.; Mussen, Timothy D.; Ercan, Ali; Bandeh, Hossein; Kavvas, M. Levent; Cech, Joseph J.; Fangue, Nann A.

    2015-01-01

    Diversion (i.e. extraction) of water from rivers and estuaries can potentially affect native wildlife populations if operation is not carefully managed. For example, open, unmodified water diversions can act as a source of injury or mortality to resident or migratory fishes from entrainment and impingement, and can cause habitat degradation and fragmentation. Fish-protection devices, such as exclusion screens, louvres or sensory deterrents, can physically or behaviourally deter fish from approaching or being entrained into water diversions. However, empirical assessment of their efficacy is often lacking or is investigated only for particular economically or culturally important fishes, such as salmonids. The Southern population of anadromous green sturgeon (Acipenser medirostris) is listed as threatened in California, and there is a high density of water diversions located within their native range (the Sacramento–San Joaquin watershed). Coupled with their unique physiology and behaviour compared with many other fishes native to California, the green sturgeon is susceptible to entrainment into diversions and is an ideal species with which to study the efficacy of mitigation techniques. Therefore, we investigated juvenile green sturgeon (188–202 days post-hatch) in the presence of several fish-protection devices to assess behaviour and entrainment risk. Using a large experimental flume (∼500 kl), we found that compared with an open diversion pipe (control), the addition of a trash-rack box, louvre box, or perforated cylinder on the pipe inlet all significantly reduced the proportion of fish that were entrained through the pipe (P = 0.03, P = 0.028, and P = 0.028, respectively). Likewise, these devices decreased entrainment risk during a single movement past the pipe by between 60 and 96%. These fish-protection devices should decrease the risk of fish entrainment during water-diversion activities. PMID:27293725

  1. Peroxiredoxin IV Protects Cells From Radiation-Induced Apoptosis in Head-and-Neck Squamous Cell Carcinoma

    International Nuclear Information System (INIS)

    Park, Jung Je; Chang, Hyo Won; Jeong, Eun-Jeong; Roh, Jong-Lyel; Choi, Seung-Ho; Jeon, Sea-Yuong; Ko, Gyung Hyuck; Kim, Sang Yoon

    2009-01-01

    Purpose: Human peroxiredoxins (Prxs) are known as a family of thiol-specific antioxidant enzymes, among which Prx-I and -II play an important role in protecting cells from irradiation-induced cell death. It is not known whether Prx-IV also protects cells from ionizing radiation (IR). Methods and Materials: To evaluate the protective role of Prx-IV in IR, we transfected full-length Prx-IV cDNA into AMC-HN3 cells, which weakly express endogenous Prx-IV, and knocked down the expression of Prx-IV with siRNA methods using AMC-HN7 cells, which express high levels of endogenous Prx-IV. Radiosensitivity profiles in these cells were evaluated using clonogenic assay, FACS analysis, cell viability, and TUNEL assay. Results: Three Prx-IV expressing clones were isolated. Prx-IV regulated intracellular reactive oxygen species (ROS) levels and made cells more resistant to IR-induced apoptosis. Furthermore, the knockdown of Prx-IV with siRNA made cells more sensitive to IR-induced apoptosis. Conclusion: The results of these studies suggest that Prx-IV may play an important role in protecting cells from IR-induced apoptosis in head-and-neck squamous cell carcinoma

  2. Device for protecting the containment vessel dome of a nuclear reactor

    International Nuclear Information System (INIS)

    Allain, A.; Filloleau, E.; Mulot, P.

    1976-01-01

    A device is disclosed for protecting the dome of a nuclear reactor containment vessel against the upward displacement of the concrete shield slab of said reactor and the resultant effects of tilting of an equipment unit mounted on the shield slab at the periphery of said slab, wherein said device comprises: (1) means for separating the equipment unit into two sections consisting of an upper section and a lower section, said lower section being rigidly fixed to said shield slab and said means being actuated by the upward displacement of said slab, (2) a system for vertical rectilinear guiding of said upper section within the containment vessel, and (3) rigid mechanical components which provide a coupling between the aforesaid upper and lower sections of the equipment unit and exert on said upper section under the action of the tilting motion of said lower section a thrust which causes the upward displacement of said upper section

  3. A simple device to protect against osteoradionecrosis induced by interstitial irradiation

    International Nuclear Information System (INIS)

    Levendag, P.C.; Visch, L.L.; Driver, N.

    1990-01-01

    The incidence of osteoradionecrosis has declined since the introduction of preventive oral hygiene programs and meticulous dental evaluations before and after irradiation. Nevertheless, radiation dose per se still remains an important factor in osteoradionecrosis. Interstitial radiation has received much attention in the past decade since the use of flexible afterloading systems. It has become common practice in large oncology centers to implant radiation carriers in bulky tumor in the oral cavity and/or oropharynx. For interstitial radiation, with or without external radiation, minimal tumor doses are often cited to be more than 70 Gy. Unfortunately, if the mandible receives more than 70 Gy, it is at risk for the development of osteoradionecrosis. Therefore a simple protective lead device has been designed for routine use in brachytherapy in oral cavity tumors to reduce the dose to the mandible. This device will diminish the potential risk of osteoradionecrosis development

  4. Research on Experiment of Islanding Protection Device of Grid-connected Photovoltaic System Based on RTDS

    Science.gov (United States)

    Zhou, Ning; Yang, Jia; Cheng, Zheng; Chen, Bo; Su, Yong Chun; Shu, Zhan; Zou, Jin

    2017-06-01

    Solar photovoltaic power generation is the power generation using solar cell module converting sunlight into DC electric energy. In the paper an equivalent model of solar photovoltaic power generation system is built in RTDS. The main circuit structure of the two-stage PV grid-connected system consists of the DC-DC, DC-AC circuit. The MPPT (Maximum Power Point Tracking) control of the PV array is controlled by adjusting the duty ratio of the DC-DC circuit. The proposed control strategy of constant voltage/constant reactive power (V/Q) control is successfully implemented grid-connected control of the inverter when grid-connected operation. The closed-loop experiment of islanding protection device of photovoltaic power plant on RTDS, verifies the correctness of the simulation model, and the experimental verification can be applied to this type of device.

  5. Related factors to workers' use of hearing protection device in knitting & ppinning factories of Yazd city based on Protection Motivation Theory

    Directory of Open Access Journals (Sweden)

    A. Barkhordi

    2009-10-01

    Full Text Available Background and aimsNoise-Induced Hearing Loss (NIHL is an important occupational disorder. High percentage of workers in occupational environments did not use the hearing protection device against harmful noise. This study was carried out to study factors related to workers' use of Hearing protection Device in Knitting & spinning factories of Yazd city based on protection motivation theory.MethodsIn this cross-sectional analytical study 280 workers of the knitting & spinning factories of Yazd City who exposed to harmful noise (over 85dB selected among the three factories by cluster sampling. The data gathered via exclusive interviews with selected workers  using the questionnaire designed based on protection motivation theory and were analyzedResults42/5 percent of workers permanently used hearing protection devices, and 20/7 percent of workers never use.There was a significant correlation between the age of workers and the mean score components of PMT; perceived severity, perceived vulnerability, perceived response efficacy and protection motivation. There was also a significant correlation between the work experience and the mean score of PMT factors; perceived severity, perceived response efficacy and perceived vulnerability. Also there was a significant correlation between workers' education level and the mean score of perceived response efficacy and there was a significant correlation between protection motivation and the mean score components of PMT; perceived vulnerability, perceived self-efficacy, perceived response efficacy, perceived costs and behaviorConclusionRegarding the significant correlations between the more constructs of PMT and protection motivation of workers for using hearing protective device, designing educational program based on PMT to increase hearing protection devices usage among workers is recommended.

  6. Fire protection devices in the controlled region of GKN nuclear power station

    International Nuclear Information System (INIS)

    Bernhardt, S.; Grauf, E.

    1976-01-01

    In the GKN nuclear power station ('Neckar reactor'), an 805 MW PWR reactor whose start-up is scheduled for the near future, fire protection measures have been realized that go far beyond those realized in other German nuclear power stations until now. One of the main reasons is that the authorities have been sensibilized by a fire in the refuelling cavity during construction and by the Browns Ferry fire and are therefore extremely thorough in their examination. Further subsections have been added to the fire prevention sections in order to provide better quenching devices for potential fire sites. (orig./AK) [de

  7. Security Hi-tech Individual Extra-light Device Mask: a new protection for [soccer] players.

    Science.gov (United States)

    Cascone, Piero; Petrucci, Bernardino; Ramieri, Valerio; Marianetti, Titto Matteo; TitoMatteo, Marianetti

    2008-05-01

    Among professional [soccer] players, a relevant incidence of maxillofacial trauma has been reported. The main challenge in these particular patients is to give them the possibility of a very short convalescence period and to make possible their agonistic activity as soon as possible. The authors here present an innovative technique to realize this--the Security Hi-tech Individual Extra-Light Device Mask, a customizable protective shield based on the player's face cast. A completely customized mask was forged over the player's face cast to protect the injured area. This mask shortens convalescence period, and due to its realization, it is comfortable and easy fitting, thus allowing the player to perform at a professional level in his sport activity in the shortest time possible.

  8. On-field evaluation of operator lens protective devices in interventional radiology

    International Nuclear Information System (INIS)

    Strocchi, S.; Chiaravalli, A.; Veronese, I.; Novario, R.

    2016-01-01

    The recent publication of the Euratom Directive 2013/59, adopting the reduction of eye lens dose limits from 150 to 20 mSv y"-"1, calls for the development of new tools and methodologies for evaluating the eye lens dose absorbed by the medical staff involved in interventional radiology practices. Moreover, the effectiveness of the protective devices, like leaded glasses, which can be employed for radiation protection purposes, must be tested under typical exposure scenarios. In this work, eye lens dose measurements were carried out on an anthropomorphic phantom simulating a physician bound to perform standard interventional neuroradiology angiographic procedures. The correlation between eye lens doses, in terms of Hp(0.07), and the equivalent dose [again in terms of Hp(0.07)] monthly measured with thermoluminescent dosemeters placed above the lead apron at the chest level was studied, in the presence and in the absence of different types of leaded glasses. (authors)

  9. Improvement of the protection devices for JT-60U LHRF antenna system

    International Nuclear Information System (INIS)

    Suzuki, Sadaaki; Seki, Masami; Shinozaki, Shinichi; Sato, Fumiaki; Hiranai, Shinichi; Hasegawa, Koichi; Moriyama, Shinichi; Ishii, Kazuhiro

    2007-09-01

    In the experiments featuring lower hybrid range of frequency (LHRF) system in JT-60U, carbon grills were attached to the plasma-facing part of the antenna in order to avoid the damage by the excessive heat load from the plasma. However some electric discharge traces were found there in the observation after the experiments. To avoid such discharges, improvements of the arc detector and the protection interlock by visible picture detection were tackled. In the arc detector, the amplification circuit was improved in order to obtain shorter response time and higher resolution of optical detection. Moreover, in visible picture detection, a new function of RF-on/off control utilizing PC image processing was added to distinguish the light of the arc from one of the plasma. This report summarizes improvement of the protection interlock device in a LHRF heating system. (author)

  10. Use of mobile device technology to continuously collect patient-reported symptoms during radiation therapy for head and neck cancer: A prospective feasibility study.

    Science.gov (United States)

    Falchook, Aaron D; Tracton, Gregg; Stravers, Lori; Fleming, Mary E; Snavely, Anna C; Noe, Jeanne F; Hayes, David N; Grilley-Olson, Juneko E; Weiss, Jared M; Reeve, Bryce B; Basch, Ethan M; Chera, Bhishamjit S

    2016-01-01

    Accurate assessment of toxicity allows for timely delivery of supportive measures during radiation therapy for head and neck cancer. The current paradigm requires weekly evaluation of patients by a provider. The purpose of this study is to evaluate the feasibility of monitoring patient reported symptoms via mobile devices. We developed a mobile application for patients to report symptoms in 5 domains using validated questions. Patients were asked to report symptoms using a mobile device once daily during treatment or more often as needed. Clinicians reviewed patient-reported symptoms during weekly symptom management visits and patients completed surveys regarding perceptions of the utility of the mobile application. The primary outcome measure was patient compliance with mobile device reporting. Compliance is defined as number of days with a symptom report divided by number of days on study. There were 921 symptom reports collected from 22 patients during treatment. Median reporting compliance was 71% (interquartile range, 45%-80%). Median number of reports submitted per patient was 34 (interquartile range, 21-53). Median number of reports submitted by patients per week was similar throughout radiation therapy and there was significant reporting during nonclinic hours. Patients reported high satisfaction with the use of mobile devices to report symptoms. A substantial percentage of patients used mobile devices to continuously report symptoms throughout a course of radiation therapy for head and neck cancer. Future studies should evaluate the impact of mobile device symptom reporting on improving patient outcomes.

  11. Design And Development Of An Automatic Single Phase Protective Device Using Ssr

    Directory of Open Access Journals (Sweden)

    Michael E.

    2017-10-01

    Full Text Available Since the discovery of energy safety has been a paramount subject matter. This we can see in todays electrical systems where protective devices such as fuse and circuit breakers are used to prevent fire hazards resulting from overload overvoltage and short circuits. However with all the revolution in technology these options may be considered less smart since the fuse made with wire strands calculated for specific current capacity faults permanently when the specified current rating is exceeded. While the circuit breaker which is made up of mechanical switch fails as a result of carbon forming and the wearing away of the contacts because of arcing. As a means of improvement this paper presents the design and development of an automatic single phase protective device using solid state relay SSR. This study is to ensure automatic cut off from power supply in cases of overvoltage above 240 V AC or when overload and short circuit current above 8amps is detected without permanent damage of a fuse placed along current path. Also the design will ensure that there is an automatic close circuit whenever the trigger switch is momentary switch is closed. The system is achieved via the use of PIC micro-controller current sensor and other discrete components. The system is tested and works well inhibiting the frequent faulting of fuses. It also helps to prevent hazard as a result of overvoltage overload and short circuit and ensures a close circuit when the trigger switch is closed.

  12. Absorbed doses by a technician, with and without (simulating) use of protection devices, in bone scintigraphy examination

    International Nuclear Information System (INIS)

    Jesus Lopes Filho, F. de; Antonio Filho, J.; Colaco, W.; Silveira, S.V. da

    1992-01-01

    The relation between the whole-body dose and the dose localized in body pants of a technician work in nuclear medicine was investigated by dosimetric films and thermoluminescent dosemeters. The investigation was made with and without a suitable protection devices. The results were discussed by a radiological protection view. (C.G.C.)

  13. A novel device for head gesture measurement system in combination with eye-controlled human machine interface

    Science.gov (United States)

    Lin, Chern-Sheng; Ho, Chien-Wa; Chang, Kai-Chieh; Hung, San-Shan; Shei, Hung-Jung; Yeh, Mau-Shiun

    2006-06-01

    This study describes the design and combination of an eye-controlled and a head-controlled human-machine interface system. This system is a highly effective human-machine interface, detecting head movement by changing positions and numbers of light sources on the head. When the users utilize the head-mounted display to browse a computer screen, the system will catch the images of the user's eyes with CCD cameras, which can also measure the angle and position of the light sources. In the eye-tracking system, the program in the computer will locate each center point of the pupils in the images, and record the information on moving traces and pupil diameters. In the head gesture measurement system, the user wears a double-source eyeglass frame, so the system catches images of the user's head by using a CCD camera in front of the user. The computer program will locate the center point of the head, transferring it to the screen coordinates, and then the user can control the cursor by head motions. We combine the eye-controlled and head-controlled human-machine interface system for the virtual reality applications.

  14. Transcranial Doppler monitoring during stenting of the carotid bifurcation: evaluation of two different distal protection devices in preventing embolization.

    Science.gov (United States)

    Rubartelli, Paolo; Brusa, Giulia; Arrigo, Alessandro; Abbadessa, Francesco; Giachero, Corinna; Vischi, Massimo; Ricca, Maria Maddalena; Ottonello, Gian Andrea

    2006-08-01

    To compare the efficacy of 2 emboli protection devices in preventing embolization during carotid artery stenting (CAS). The GuardWire distal occlusion system (n=19) and the distal FilterWire EX (n=12) were compared in 31 consecutive patients (24 men; mean age 71+/-10 years) monitored with transcranial Doppler for microembolic signals before, during, and after CAS. The choice of the protection device was based on availability and on the patency of the contralateral carotid artery. The baseline characteristics were similar in the patients treated under protection from either device. Placement and retrieval of the protection device, stenting, and postdilation were technically successful in all patients. Two patients suffered a transient ischemic attack shortly after the procedure; no other adverse cardiovascular events occurred at 30 days. Compared to the GuardWire, the use of the FilterWire was associated with more microembolic signals during stent deployment (77.4+/-33.5 versus 1.07+/-1.94, pprotection device (21.4+/-15.4 versus 10.9+/-8.3, p=0.051). Consequently, the total amount of microembolic signals during the procedure was higher when the filter device was employed (183.0+/-42.1 versus 31.7+/-12.0, p<0.0001). The distal occlusion device appears to be more effective than the filter in reducing distal embolization detected by transcranial Doppler monitoring.

  15. New challenge for the radiation protection: devices for the radioactivity dispersion

    International Nuclear Information System (INIS)

    Mora, J. C.; Robles, B.; Cancio, C.

    2006-01-01

    In recent years the terrorist attacks produced in several countries have changed the mind of the security experts. This has also included the Radiation Protection aspects. Newly considered features have required the update of emergency response and preparedness, ad well as a greater emphasis on security. Within the Radiation Protection field has been introduced the radiological and nuclear terrorism definition. almost every organism and research centre involved in Radiation Protection is nowadays working on. The possible terrorist attack scenarios have already been defined and the use of an explosive to disperse radioactive material, known as a Radiation Dispersion Devices (RDD), has been specified as the most probable one. Studies to mitigate against the chance of attack and to mitigate the consequences of any attack with a RDD are complex, due to the innovation that introduce. This leads to a need to take some immediate preventative actions and to carry out additional R and D efforts. This document presents some considerations on the possible RDD design and behaviour in order to prevent and prepare against a possible attack. (Author) 17 refs

  16. The use of hearing protection devices with approach risk perception of noise induced hearing loss in several manufacturing industry

    Directory of Open Access Journals (Sweden)

    Behzad Fouladi Deahghi

    2015-06-01

    Full Text Available Background & Objective : Noise is a widespread physical agent and although is a most risk factors in workplaces that workers of health to exposed. Thus, different actions is done for reduce exposure to it in work places, which one of them is use of hearing protection devices. The use of hearing protection devices with approach risk perception of noise induced hearing loss in several manufacturing industry Method: This study was Cross-sectional study and done in five industrial unit with a sound pressure level more of 85 dB-A with the participation of 340 workers. To collect data , individual risk perception and self-investigator questionnaires were used. After collecting data, statistical analysis including Cronbach's alpha and regression were used to analyze the data. Results : Range use of hearing protection devices during shifts work by workers, respectively equal to: 50.4% sometimes, 31.58% never and 18.2% at all times. Also, results indicate significant differences between individual differences and hearing protection devices. Conclusion : Results of this study showed that individual risk perception as an important factor, can do a significant role in predicting the behavior of personals in the use of hearing protection devices, which should be considered in any design and implementation of hearing protection program.

  17. Mouth-opening device as a treatment modality in trismus patients with head and neck cancer and oral submucous fibrosis: a prospective study.

    Science.gov (United States)

    Li, Yu-Hsuan; Chang, Wei-Chin; Chiang, Tien-En; Lin, Chiun-Shu; Chen, Yuan-Wu

    2018-04-26

    This study investigated the clinical effectiveness of intervention with an open-mouth exercise device designed to facilitate maximal interincisal opening (MIO) and improve quality of life in patients with head and neck (H&N) cancer and oral submucous fibrosis (OSF). Sixty patients with H&N cancer, OSF, and trismus (MIO cancer and OSF and improve mouth-opening range and quality of life.

  18. Protecting Touch: Authenticated App-To-Server Channels for Mobile Devices Using NFC Tags

    Directory of Open Access Journals (Sweden)

    Fernando Kaway Carvalho Ota

    2017-07-01

    Full Text Available Traditional authentication methods (e.g., password, PIN often do not scale well to the context of mobile devices in terms of security and usability. However, the adoption of Near Field Communication (NFC on a broad range of smartphones enables the use of NFC-enabled tokens as an additional authentication factor. This additional factor can help to improve the security, as well as usability of mobile apps. In this paper, we evaluate the use of different types of existing NFC tags as tokens for establishing authenticated secure sessions between smartphone apps and web services. Based on this evaluation, we present two concepts for a user-friendly secure authentication mechanism for mobile apps, the Protecting Touch (PT architectures. These two architectures are designed to be implemented with either end of the spectrum of inexpensive and widely-available NFC tags while maintaining a reasonable trade-off between security, availability and cost.

  19. Investigation of Vehicle Rear Under Run Protection Device (RUPD) Using Aluminium Foam

    Science.gov (United States)

    Nagaraj Goud, B.; pachori, Avinash

    2017-08-01

    Whenever the passenger cars meet with accidents with the heavy duty truck from rear, it will tend to penetrate under the truck bed called truck trailer under-ride crash. This is responsible for the thousands of accidents, causing severe injuries and spot death. This is mostly due to the lack of effective guarding system. The Present paper gives an importance on energy absorption mechanism of a Rear under Run Protection Device (RUPD) under crash effect of the truck. The aim of the study is to replace Steel RUPD with aluminum foam, which promises an improvement of vehicle crashworthiness as well as to reduce weight of the vehicle. The aluminum foam is selected due to the high specific strength and specific stiffness. This inborn character makes it a promising candidate in the modern lightweight structures in the automotive engineering which can contribute to the improvement of mileage in addition to safety of the occupants.

  20. Endovascular rescue of a fused monorail balloon and cerebral protection device.

    Science.gov (United States)

    Campbell, John E; Bates, Mark C; Elmore, Michael

    2007-08-01

    To present a case of successful endovascular retrieval of a monorail predilation balloon fused to an embolic protection device (EPD) in the distal internal carotid artery (ICA) of a high-risk symptomatic patient. A 60-year-old man with documented systemic atherosclerotic disease had a severe (>70%) restenosis in the left ICA 3 years after endarterectomy. He was scheduled for carotid artery stenting (CAS) with cerebral protection; however, he developed unstable angina and was transferred to our facility, where the admitting team decided that staged CAS followed by coronary bypass grafting would be the best option. During the CAS procedure, a 6-mm AccuNet filter was passed across the lesion via a 6-F carotid sheath and deployed in the distal ICA without incident. However, the 4-x20-mm predilation monorail balloon was then advanced without visualizing the markers, resulting in inadvertent aggressive interaction that trapped the balloon's tip in the filter. Several maneuvers to separate the devices were unsuccessful. Finally, the filter/balloon combination was moved gently retrograde until the balloon was straddling the subtotal ICA lesion. The lesion was dilated to 4 mm with the balloon, and the sheath was gently advanced across the lesion as the balloon was deflated. Angiography excluded interval occlusion of the filter from the embolic debris during the aforementioned aggressive maneuvers and documented antegrade flow. The filter was slowly withdrawn into the 6-F sheath with simultaneous aspiration. A second 6-mm filter was deployed, and the procedure was completed satisfactorily. The patient did well, with no neurological sequelae. EPDs are an essential in carotid artery stenting and, keeping in mind the potential risks associated with their use, will help the operator avoid complications such as this one.

  1. Quality control devices for intraoperative gamma probes: physical, technical and radiation protection aspects

    International Nuclear Information System (INIS)

    Varela, C.; Diaz, M.; Salvador, F.J.; Hernandez, M.; Jimenez, P.

    2008-01-01

    Now a day, radio guided surgery -a novelty in Nuclear Medicine- is increasingly used. The clinical efficiency of these procedures requires the existence of well-trained professionals and implementation of quality assurance programs. It is essential for achieving the main objective, which is an effective and safe surgical procedure, a reliable performance of the detection device. Probes' parameters must remain within the acceptance limits, so they should be checked periodically. NEMA Standards Publication NU 3-2004 'Performance Measurement and Quality Control Guidelines for Non-Imaging Intraoperative Gamma Probes' recommends 13 tests; although only 3 of them -sensibility in air, visual inspection and power source check- are considered as steadiness tests. Space resolution in a scatter medium is also a test that needs to be carried out. These tests are considerably complex since open radioactive sources are used into a liquid medium in most of the procedures. The immersion of the probe and of the radioactive sources in each case represents both risks of radioactive contamination, and of damages to the equipment. On the other hand, tests in air demand a good reproducibility. Since they are recommended be carried out before any surgery procedure, they also should be easy and quick. This paper presents 3 devices with its accessories for acceptance and quality control tests of intraoperative gamma probes. They were designed and built taking into consideration important aspects of radiological protection to handle the calibration sources and probes, both in air and into a scatter medium. These devices are designed to fit any kind of probe. Regulatory bodies as part of their instrument audits can also use them. (author)

  2. Burst protection device for largely cylindrical steam raising units, preferably of pressurized water nuclear power stations

    International Nuclear Information System (INIS)

    Mutzl, J.

    1978-01-01

    This burst protection device controls forces to be expected in an accident by resolving them into axial (vertical) and radial (horizontal) components, which are taken by a large number of elements stressed in tension. The steam raising unit is surrounded by a containment, but remains easily accessible. The containment consists of a steel jacket, lid and floor. Several cylindrical sections above one another form the steel jacket, which surrounds the steam raising unit with an intermediate insulating layer of concrete. The insulating concrete cylinder is of several times the thickness of the steel jacket, and also consists of cylindrical sections. An outer supporting ring for the lid and floor of the containment have outside diameters which project beyond the jacket. Prestressed circumferential vertical tension ropes between the supporting ring and floor take any additional tensional forces. The lid is domed with downward curvature towards the upper boiler dome. Internal bursting forces produce compressive stresses in the lid, which thus pass along its outside diameter into the surrounding ring. The lid, which is devided along one diameter, makes dismantling and access to the boiler easy even with a central steam pipe going upwards. The floor of the burst protection is also the floor of the steam raising unit. It is of several times the thickness of the tube floor, which, with its spacing above the floor forms the usual inlet and outlet space for the reactor cooling water. The main coolant pump installed there is driven by an external motor through a floor penetration. (HP) [de

  3. Weibull aging models for the single protective channel unavailability analysis by the device of stages

    International Nuclear Information System (INIS)

    Nunes, M.E.C.; Noriega, H.C.; Melo, P.F.F.

    1997-01-01

    Among the features to take into account in the unavailability analysis of protective channels, there is one that plays a dominant role - that of considering the equipment aging. In this sense, the exponential failure model is not adequate, since some transition rates are no more constant. As a consequence, Markovian models cannot be used anymore. As an alternative, one may use the device of stages that allows for transforming a Non Markovian model into an equivalent Markovian one by insertion of a fictitious states set, called stages. For a given time-dependent transition rate, its failure density is analysed as to the best combination of exponential distributions and then the moments of the original distribution and those of the combination are matched to estimate the necessary parameters. In this paper, the aging of the protective channel is supposed to follow Weibull distributions. Typical means and variances for the times to failure are considered and combinations of stages are checked. Initial conditions features are discussed in connection with states that are fictitious and to check the validity of the developed models. Alternative solutions by the discretization of the failure rates are generated. The results obtained agree quite well. (author). 7 refs., 6 figs

  4. Integrated assessment of pedestrian head impact protection in testing secondary safety and autonomous emergency braking.

    Science.gov (United States)

    Searson, D J; Anderson, R W G; Hutchinson, T P

    2014-02-01

    Pedestrian impact testing is used to provide information to the public about the relative level of protection provided by different vehicles to a struck pedestrian. Autonomous Emergency Braking (AEB) is a relatively new technology that aims to reduce the impact speed of such crashes. It is expected that vehicles with AEB will pose less harm to pedestrians, and that the benefit will come about through reductions in the number of collisions and a change in the severity of impacts that will still occur. In this paper, an integration of the assessment of AEB performance and impact performance is proposed based on average injury risk. Average injury risk is calculated using the result of an impact test and a previously published distribution of real world crash speeds. A second published speed distribution is used that accounts for the effects of AEB, and reduced average risks are implied. This principle allows the effects of AEB systems and secondary safety performance to be integrated into a single measure of safety. The results are used to examine the effect of AEB on Euro NCAP and ANCAP assessments using previously published results on the likely effect of AEB. The results show that, given certain assumptions about AEB performance, the addition of AEB is approximately the equivalent of increasing Euro NCAP test performance by one band, which corresponds to an increase in the score of 25% of the maximum. Copyright © 2013 Elsevier Ltd. All rights reserved.

  5. Gender differences in use of hearing protection devices among farm operators

    Directory of Open Access Journals (Sweden)

    Marjorie C McCullagh

    2016-01-01

    Full Text Available Purpose: Although farm operators have frequent exposure to hazardous noise and high rates of noise-induced hearing loss, they have low use of hearing protection devices (HPDs. Women represent about one-third of farm operators, and their numbers are climbing. However, among published studies examining use of HPDs in this worker group, none have examined gender-related differences. The purpose of this study was to examine gender-related differences in use of hearing protection and related predictors among farm operators. Materials and Methods: Data previously collected at farm shows and by telephone were analyzed using t-tests and generalized linear model with zero inflated negative binomial (ZINB distribution. Findings: The difference in rate of hearing protector use between men and women farm operators was not significant. There was no difference between men and women in most hearing protector-related attitudes and beliefs. Conclusion: Although men and women farm operators had similar rates of use of hearing protectors when working in high-noise environments, attitudes about HPD use differed. Specifically, interpersonal role modeling was a predictor of HPD use among women, but not for men. This difference suggests that while farm operators of both genders may benefit from interventions designed to reduce barriers to HPD use (e.g., difficulty communicating with co-workers and hearing warning sounds, farm women have unique needs in relation to cognitive-perceptual factors that predict HPD use. Women farm operators may lack role models for use of HPDs (e.g., in peers and advertising, contributing to their less frequent use of protection.

  6. First-in-man use of a novel embolic protection device for patients undergoing transcatheter aortic valve implantation.

    Science.gov (United States)

    Naber, Christoph K; Ghanem, Alexander; Abizaid, Alexander A; Wolf, Alexander; Sinning, Jan-Malte; Werner, Nikos; Nickenig, Georg; Schmitz, Thomas; Grube, Eberhard

    2012-05-15

    We describe the first-in-human experience with a novel cerebral embolic protection device used during transcatheter aortic valve implantation (TAVI). One current challenge of TAVI is the reduction of procedural stroke. Procedural mobilisation of debris is a known source of cerebral embolisation. Mechanical protection by transient filtration of cerebral blood flow might reduce the embolic burden during TAVI. We aimed to evaluate the feasibility and safety of the Claret CE Pro™ cerebral protection device in patients undergoing TAVI. Patients scheduled for TAVI were prospectively enrolled at three centres. The Claret CE Pro™ (Claret Medical, Inc. Santa Rosa, CA, USA) cerebral protection device was placed via the right radial/brachial artery prior to TAVI and was removed after the procedure. The primary endpoint was technical success rate. Secondary endpoints encompassed procedural and 30-day stroke rates, as well as device-related complications. Deployment of the Claret CE Pro™ cerebral protection device was intended for use in 40 patients, 35 devices were implanted into the aortic arch. Technical success rate with delivery of the proximal and distal filter was 60% for the first generation device and 87% for the second-generation device. Delivery times for the first-generation device were 12.4±12.1 minutes and 4.4 ± 2.5 minutes for the second-generation device (pto the Claret CE Pro System was 19.6 ± 3.8 ml. Captured debris was documented in at least 19 of 35 implanted devices (54.3%). No procedural transient ischaemic attacks, minor strokes or major strokes occurred. Thirty-day follow-up showed one minor stroke occurring 30 days after the procedure, and two major strokes both occurring well after the patient had completed TAVI. The use of the Claret CE Pro™ system is feasible and safe. Capture of debris in more than half of the patients provides evidence for the potential to reduce the procedural cerebral embolic burden utilising this dedicated filter

  7. Application of Detailed Phase Comparison Protection Models for the Analysis of its Operation in Networks with Facts Devices

    Directory of Open Access Journals (Sweden)

    Ruban Nikolay Yu.

    2015-01-01

    Full Text Available The problem of relay protection misoperations in networks with FACTS devices is considered in the paper. It is offered a solution to this problem for a phase comparison protection of transmission power line through the use of its detailed model for the analysis of the functioning for a case of various normal, emergency and post-emergency modes of electric power systems. The research results of this approach are given in the paper.

  8. Functional needs which led to the use of digital computing devices in the protection system of 1300 MW units

    International Nuclear Information System (INIS)

    Dalle, H.

    1986-01-01

    After a review of classical protection functions used in 900 MW power plants, it is concluded that in order to have functioning margins it is useful to calculate more finely the controled parameters. These calculating needs lead to the use of digital computing devices. Drawing profit from the new possibilities one can improve the general performances of the protection system with regard to availability, safety and maintenance. These options in the case of PALUEL led to the realization of SPIN, described here

  9. C2-Ceramide Induces Cell Death and Protective Autophagy in Head and Neck Squamous Cell Carcinoma Cells

    Directory of Open Access Journals (Sweden)

    Wenyuan Zhu

    2014-02-01

    Full Text Available Ceramides are second messengers involved in several intracellular processes in cancer cells, amongst others. The aim of this study was to evaluate the anti-tumor efficacy of C2-ceramide (C2-Cer; N-acetyl-D-sphingosine by investigating cell death and autophagy in head and neck squamous cell carcinoma (HNSCC cells. C2-Cer showed concentration-dependent cytotoxicity in HN4 and HN30 cell lines. It simultaneously induced caspase-3-independent apoptosis and programmed necrosis. C2-Cer markedly increased the expression level of microtubule-associated protein 1 light chain 3B (LC3B type II associated with protective autophagy. An autophagy inhibitor enhanced C2-Cer-mediated cytotoxicity, while a programmed-necrosis inhibitor produced the opposite effect. Furthermore, C2-Cer up-regulated the phosphorylation of extracellular signal-regulated kinase 1/2, but down-regulated its downstream substrate phospho-mammalian target of rapamycin (p-mTOR during the autophagy process. These results suggested that C2-Cer exerts anti-tumor effects by inducing programmed apoptosis and necrosis in HNSCC, and these cytotoxic effects are enhanced by an autophagy inhibitor.

  10. Percutaneous renal angioplasty and stenting: application of embolic protection device in patients with normal renal function

    International Nuclear Information System (INIS)

    Tong Xiaoqiang; Yang Ming; Wang Jian; Song Li; Wang Chao; Lv Yongxing; Sun Hongliang; Zou Yinghua; Yin Ming

    2007-01-01

    Objective: To investigate the Value of embolic protection device (EPD)in renal artery stenting (RAS)for the patients with normal renal function. Methods: Total 24 patients (26 renal arteries) suffering from renal artery stenosis with normal serum creatinine were divided into two groups: EPD group (n12)and non-EPD group (n=12). Serum creatinine was calculated and analized statistically between the two groups, 1 month and 6months after stenting respectively, and followed by comparisons taking inside of each group and between both groups. Results: Serum creatinine of the EPD and non-EPD groups before, 1 month and 6 month after stenting were(99.18 ± 18.26) μmol/L, (101.73 ± 12.65) μmol/L, (96.82 ± 15.81) μmol/L and (100.18 ± 19.81) μmol/L, (107.36 ± 29.49) μmol/L, (127.64 ± 88.05) μmol/L, respectively; showing no significant difference inside each group individually (P>0.05), and also no statistically significant difference between the two groups (P>0.05). Conclusion: For the patients suffering from renal artery stenosis with normal serum creatinine, application of EPD may have no impact on renal function. Further evaluation is needed. (authors)

  11. About the influence of wheel slide protection devices action on longitudinal dynamic of trains

    Directory of Open Access Journals (Sweden)

    Cruceanu Cătălin

    2017-01-01

    Full Text Available Wheel slide protection devices (WSPD are destined to avoid important sliding of wheels during braking actions in case of temporarily impaired wheel-rail adhesion by correspondent reductions of air pressure in brake cylinders. Accordingly, longer braking distances and higher longitudinal in-train forces occur, potentially affecting the traffic safety and the passengers comfort. A general analyse and evaluation of these effects are the main targets of the present study. The theoretical considerations are sustained by simulations of braking process, considering situations of normal, respectively diminished wheel-rail adhesion determining random actuations of WSPD. The air pressure evolution in brake cylinders of was experimentally determined on a computerized brake system test stand and adequately used as input in simulations. The results indicate an increase of in-train forces and a more complex evolution of the longitudinal dynamic actions between the vehicles in the case of degraded wheel-rail adhesion, when the random actuation of WSPD have major influence in the whole braking process.

  12. Optical-electronic device based on diffraction optical element for control of special protective tags executed from luminophor

    Science.gov (United States)

    Polyakov, M.; Odinokov, S.

    2017-05-01

    The report focuses on special printing industry, which is called secure printing, which uses printing techniques to prevent forgery or falsification of security documents. The report considered the possibility of establishing a spectral device for determining the authenticity of certain documents that are protected by machine-readable luminophor labels. The device works in two spectral ranges - visible and near infrared that allows to register Stokes and anti-Stokes spectral components of protective tags. The proposed device allows verification of the authenticity of security documents based on multiple criteria in different spectral ranges. It may be used at enterprises related to the production of security printing products, expert units of law enforcement bodies at check of authenticity of banknotes and other structures.

  13. To a question on thermal protection of constructional elements of vacuum-plasma devices

    International Nuclear Information System (INIS)

    Borisko, V.N.; Borisko, S.V.; Zinovev, D.V.; Lapshin, V.I.; Tselujko, A.F.

    2005-01-01

    The progress in development of vacuum-plasma devices is connected with the design and creation of constructional elements from materials, which have a high erosion resistance and can maintain the large specific flux of energy per effective area. Recently as the materials of such constructional elements it was offered to use the reversible sorbents of hydrogen of Zr-V system, which have high-rates of sorption-desorption and large thermal effect of the hydride phases decomposition. In the paper an experimental research of the thermal conditions features of the metal-hydride electrodes, which subjected of the energy loads in the vacuum-plasma devices, are given. The simulation of the energy loads on the electrodes was carried out with the help of gas discharge plasma as there is an possibility to vary the energy spectrum of the bombarding particles and to gather a necessary radiation dose to the material surface. For comparative examinations of various materials under the irradiation by high-energy heavy particles it is the most convenient to use the Penning discharge. In this case, the cathodes made of different materials are under the identical conditions even at the change of working discharge modes. Therefore in the device on the basis of the Penning discharge the cathodes of metal-hydride and stainless steel were set. It was detected, that the increase of the temperature gradient of metal-hydride cathode goes down with the increase of discharge current value. The dependence of operating temperatures difference of cathodes from exposure time has shown that the temperature of the metal-hydride cathode is sufficiently lower than the temperature of the stainless steel cathode. Such a softening of the thermal operation conditions of the metal hydride cathode is caused by thermal decomposition of hydride phases. Besides there is the energy flow dissipation of bombarding particles on the protective gas target formed by desorbed hydrogen. The considerable decrease of

  14. Multicriteria Analysis model for the comparison of different rockfalls protection devices

    Science.gov (United States)

    Mignelli, C.; Pomarico, S.; Peila, D.

    2012-04-01

    which provides a comparison of the considered options. The developed model takes into account five different aspects of the decision-making process (economic, environmental, design, transport and social aspects) that have been organized according the hierarchical framework of the AHP technique. The criteria that were identified in the analysis and their weights, in the decision-making process, have been discussed and determined by means of specific focus groups with technical experts in the geo-engineering field. Three different protection devices, usually used for rockfall protection (embankment, shelter topped by rockfall barrier and tunnel), are compared through the AHP method, in a specific "geo" environment to show the feasibility of the method. The application of the AHP technique, which was performed using the Expert Choice software, allowed the most relevant aspects of the decision-making process to be highlighted and showing how the proposed method can be a valuable tool for public administration. Furthermore, in order to test the robustness of the proposed model a sensitivity analysis was carried out. The research has an originality value since it focuses on a participative methodological approach thus making the decision process more traceable and reliable.

  15. Renal embolic protection devices improve blood flow after stenting for atherosclerotic renal artery stenosis.

    Science.gov (United States)

    Paul, Timir K; Lee, John H; White, Christopher J

    2012-11-15

    We sought to measure angiographic renal frame counts (RFC), as a quantitative angiographic assessment of renal blood flow, to evaluate microvascular compromise due to atheroembolism associated with RAS. Atheroembolism associated with renal artery stenting (RAS) has been implicated as a cause for worsening renal function following successful intervention. Use of a distal embolic protection device (EPD) during RAS has been shown to be safe with debris capture in a high percentage of cases. However, objective benefit for renal function with EPD has been difficult to demonstrate. A control group of 30 consecutive patients (33 kidneys) who underwent RAS without EPD were compared with 33 consecutive patients (33 kidneys) who underwent RAS with EPD using RFC measurement. The prestent and poststent mean RFC for the control group was 30.4 ± 12.1 vs. 23.7 ± 9.9 (P = 0.002) and for the EPD group it was 42.6 ± 12.6 vs. 28.3 ± 9.2 (P renal blood flow, manifested by a greater reduction of the RFC (Δ RFC) 14.2 ± 15.2 vs. 6.7 ± 11.7 (P = 0.03) compared with the control group. The use of an EPD was associated with a much larger improvement in renal blood flow (lower RFC) following RAS. This suggests that EPD's may be effective in preventing renal atheroembolic injury and that a controlled trial measuring the impact of EPD's on renal blood flow following RAS should be performed. Copyright © 2012 Wiley Periodicals, Inc.

  16. Measurement of hearing protection devices performance in the workplace during full-shift working operations.

    Science.gov (United States)

    Nélisse, Hugues; Gaudreau, Marc-André; Boutin, Jérôme; Voix, Jérémie; Laville, Frédéric

    2012-03-01

    The effectiveness of hearing protection devices (HPDs), when used in workplace conditions, has been shown over the years to be usually lower than the labeled values obtained under well-controlled laboratory conditions. Causes for such discrepancies have been listed and discussed by many authors. This study is an attempt to understand the issues in greater details and quantify some of these factors by looking at the performance of hearing protectors as a function of time during full work shift conditions. A non-invasive field microphone in the real ear (F-MIRE)-based method has been developed for measuring the effectiveness of different HPDs as a function of time in the workplace. Details of the test procedures, the equipment used, and the post-processing operations are presented and discussed. The methodology was developed in such a way that a complete time and frequency representation are possible. The system was used on a total of 24 workers in eight different companies. Work shifts of up to 9-h long were recorded. Various types of earmuffs and one type of molded earplugs were tested. Attenuation data reported as a function of time showed, for most workers tested, considerable fluctuations over entire work shift periods. Parts of these fluctuations are attributed to variations in the low-frequency content in the noise (in particular for earmuffs) as well as poor insertion and/or fitting of earplugs. Lower performances than laboratory-based ones were once again observed for most cases tested but also, important left and right ear differences were obtained for many individuals. When reported as a function of frequency, the attenuation results suggested that the few approximations used to relate the measurements to subjective real-ear-attenuation-at-threshold (REAT) data were realistic. The use of individualized attenuation data and performance ratings for HPDs as well as a good knowledge of the ambient noise in the workplace are key ingredients when evaluating the

  17. Social marketing campaign promoting the use of respiratory protection devices among farmers.

    Science.gov (United States)

    Pounds, Lea; Duysen, Ellen; Romberger, Debra; Cramer, Mary E; Wendl, Mary; Rautiainen, Risto

    2014-01-01

    This article describes the formal use of marketing concepts in a systematic approach to influence farmers to voluntarily increase respiratory protective device (RPD) use. The planning process for the project incorporated six key decision or action points, each informed by formative research or health behavior theory. The planning process included developing behavior change strategies based on a 4P model (product, price, place, and promotion). The resulting campaign elements included print and e-mail messages that leveraged motivators related to family and health in order to increase farmers' knowledge about the risks of exposure to dusty environments, four instructional videos related to the primary barriers identified in using RPDs, and a brightly colored storage bag to address barriers to using RPDs related to mask storage. Campaign implementation included a series of e-mails using a bulk e-mail subscription service, use of social media in the form of posting instructional videos on a YouTube channel, and in-person interactions with members of the target audience at farm shows throughout the Central States Center for Agricultural Safety and Health seven-state region. Evaluation of the e-mail campaigns indicated increased knowledge about RPD use and intent to use RPDs in dusty conditions. YouTube analytic data indicated continuing exposure of the instructional videos beyond the life of the campaign. The project demonstrates the efficacy of a planning process that incorporates formative research and clear decision points throughout. This process could be used to plan health behavior change interventions to address other agriculture-related health and safety issues.

  18. Soft tissue conduction as a possible contributor to the limited attenuation provided by hearing protection devices

    Directory of Open Access Journals (Sweden)

    Shai Chordekar

    2016-01-01

    Full Text Available Context: Damage to the auditory system by loud sounds can be avoided by hearing protection devices (HPDs such as earmuffs, earplugs, or both for maximum attenuation. However, the attenuation can be limited by air conduction (AC leakage around the earplugs and earmuffs by the occlusion effect (OE and by skull vibrations initiating bone conduction (BC. Aims: To assess maximum attenuation by HPDs and possible flanking pathways to the inner ear. Subjects and Methods: AC attenuation and resulting thresholds were assessed using the real ear attenuation at threshold (REAT procedure on 15 normal-hearing participants in four free-field conditions: (a unprotected ears, (b ears covered with earmuffs, (c ears blocked with deeply inserted customized earplugs, and (d ears blocked with both earplugs and earmuffs. BC thresholds were assessed with and without earplugs to assess the OE. Results: Addition of earmuffs to earplugs did not cause significantly greater attenuation than earplugs alone, confirming minimal AC leakage through the external meatus and the absence of the OE. Maximum REATs ranged between 40 and 46 dB, leading to thresholds of 46–54 dB HL. Furthermore, calculation of the acoustic impedance mismatch between air and bone predicted at least 60 dB attenuation of BC. Conclusion: Results do not support the notion that skull vibrations (BC contributed to the limited attenuation provided by traditional HPDs. An alternative explanation, supported by experimental evidence, suggests transmission of sound to inner ear via non-osseous pathways such as skin, soft tissues, and fluid. Because the acoustic impedance mismatch between air and soft tissues is smaller than that between air and bone, air-borne sounds would be transmitted to soft tissues more effectively than to bone, and therefore less attenuation is expected through soft tissue sound conduction. This can contribute to the limited attenuation provided by traditional HPDs. The present study

  19. Local setup errors in image-guided radiotherapy for head and neck cancer patients immobilized with a custom-made device.

    Science.gov (United States)

    Giske, Kristina; Stoiber, Eva M; Schwarz, Michael; Stoll, Armin; Muenter, Marc W; Timke, Carmen; Roeder, Falk; Debus, Juergen; Huber, Peter E; Thieke, Christian; Bendl, Rolf

    2011-06-01

    To evaluate the local positioning uncertainties during fractionated radiotherapy of head-and-neck cancer patients immobilized using a custom-made fixation device and discuss the effect of possible patient correction strategies for these uncertainties. A total of 45 head-and-neck patients underwent regular control computed tomography scanning using an in-room computed tomography scanner. The local and global positioning variations of all patients were evaluated by applying a rigid registration algorithm. One bounding box around the complete target volume and nine local registration boxes containing relevant anatomic structures were introduced. The resulting uncertainties for a stereotactic setup and the deformations referenced to one anatomic local registration box were determined. Local deformations of the patients immobilized using our custom-made device were compared with previously published results. Several patient positioning correction strategies were simulated, and the residual local uncertainties were calculated. The patient anatomy in the stereotactic setup showed local systematic positioning deviations of 1-4 mm. The deformations referenced to a particular anatomic local registration box were similar to the reported deformations assessed from patients immobilized with commercially available Aquaplast masks. A global correction, including the rotational error compensation, decreased the remaining local translational errors. Depending on the chosen patient positioning strategy, the remaining local uncertainties varied considerably. Local deformations in head-and-neck patients occur even if an elaborate, custom-made patient fixation method is used. A rotational error correction decreased the required margins considerably. None of the considered correction strategies achieved perfect alignment. Therefore, weighting of anatomic subregions to obtain the optimal correction vector should be investigated in the future. Copyright © 2011 Elsevier Inc. All rights

  20. Main radiation protection actions for medical personnel as primary responders front of an event with radiological dispersive device

    International Nuclear Information System (INIS)

    Duque, Hildanielle Ramos

    2015-01-01

    After the terrorist attack in New York, USA, in 2001, there was a worldwide concern about possible attacks using radioactive material in conventional detonators, called as Radiological Dispersal Device (RDD) or 'dirty bomb'. Several studies have been and are being made to form a global knowledge about this type of event. As until now, fortunately, there has not been an event with RDD, the Goiania Radiological Accident in Brazil, 1987, is used as a reference for decision-making. Several teams with technical experts should act in an event with RDD, but the medical staffs who respond quickly to the event must be properly protected from the harmful effects of radiation. Based on the radiological protection experts performance during the Goiania accident and the knowledge from lessons learned of many radiological accidents worldwide, this work presents an adaptation of the radiation protection actions for an event with RDD that helps a medical team as primary responders. The following aspects are presented: the problem of radioactive contamination from the explosion of the device in underground environment, the actions of the first responders and evaluation of health radiation effects. This work was based on specialized articles and papers about radiological accidents and RDD; as well as personal communication and academic information of the Institute of Radiation Protection and Dosimetry. The radiation protection actions, adapted to a terrorist attack event with RDD, have as a scenario a subway station in the capital. The main results are: the use of the basic radiation protection principle of time because there is no condition to take care of a patient keeping distance or using a shielding; the use of full appropriate protection cloths for contaminating materials ensuring the physical safety of professionals, and the medical team monitoring at the end of a medical procedure, checking for surface contamination. The main conclusion is that all medical actions

  1. Hybrid reed: Solid-state devices are a new generation of protective relays

    Directory of Open Access Journals (Sweden)

    Gurevich Vladimir

    2007-01-01

    Full Text Available Research and development in the field of electromechanical protective relays has not been conducted for tens of years. Author’s approach allows viewing the problem of re-equipment of relay protection in a new way. In the author’s opinion combination of reed switches with magnetic circuits and semiconductor elements opens new avenues in development of the promising protective relays featuring reliability, simplicity and low cost. Examples of protective relays made with these elements are given below.

  2. Biometric template data protection in mobile device environment using XML-database

    DEFF Research Database (Denmark)

    Thirumathyam, Rubathas; Derawi, Mohammad; Fischer, Paul

    2010-01-01

    recognition or gait recognition. To gain a real understanding of how it is possible to protect the biometric data, this paper first starts out with introducing a technique for security in a biometric system and emphasizes that template protection is important by going through the vulnerabilities and threats....... Furthermore, it points out requirements for template protection, a recital of various template protection schemes and a brief overview of biometric standards....

  3. 46 CFR 111.50-5 - Location of overcurrent protective devices.

    Science.gov (United States)

    2010-10-01

    ... Section 111.50-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Overcurrent Protection § 111.50-5 Location of overcurrent protective... primary side of a single phase transformer (two wire with single-voltage secondary) also protects the...

  4. A novel mechanical design of broken rope protection device for enhancing the safety performances of overhead manned equipment in coal mine

    Directory of Open Access Journals (Sweden)

    Xiaoguang Zhang

    2015-08-01

    Full Text Available A novel mechanical design of the broken rope protection device is proposed to enhance the safety performances of the overhead manned equipment. According to the operating characteristics and functional requirements of the overhead manned equipment, a three-dimensional mechanical model of the broken rope protection device was redesigned. Based on the known parameters of the mechanical model, the stress and strength of the main components are readjusted using the statics characteristics of finite element analysis. To ensure the reliability of the control system of the broken rope protection device, the process of people’s falling, the response performance of the tension sensor, and the signal extraction of the broken rope are analyzed under different loading and unloading speeds. The working principle of the broken rope protection device is expounded in detail. The experimental results showed that better effect is obtained by the new broken rope protection device, which is characterized by good durability, low investment, and high reliability.

  5. Simple device for the positioning and fixation of the head in radiotherapy of cerebral tumors in frontal and lateral position

    International Nuclear Information System (INIS)

    Niewald, M.; Uhlmann, U.; Schnabel, K.; Lehmann, W.; Leetz, H.K.

    1988-01-01

    In radiotherapy of cerebral tumors in the occipital, central and parietal area it can be favourable to fix the patient's head in frontal or lateral position. It is true that this problem can be solved by manufacturing individual face masks of PVC with the vacuum deep-drawing method, but this method is very time- and cost-consuming. The present study suggests a simplified method using the thermoplastic polyester 'Orifit'. Such a mask provides a good immobilization and can be manufactured in 10 to 15 minutes without bothering much the patient. Simulation and computed tomography are not substantially affected by the material. (orig.) [de

  6. Thin-film encapsulation of organic electronic devices based on vacuum evaporated lithium fluoride as protective buffer layer

    Science.gov (United States)

    Peng, Yingquan; Ding, Sihan; Wen, Zhanwei; Xu, Sunan; Lv, Wenli; Xu, Ziqiang; Yang, Yuhuan; Wang, Ying; Wei, Yi; Tang, Ying

    2017-03-01

    Encapsulation is indispensable for organic thin-film electronic devices to ensure reliable operation and long-term stability. For thin-film encapsulating organic electronic devices, insulating polymers and inorganic metal oxides thin films are widely used. However, spin-coating of insulating polymers directly on organic electronic devices may destroy or introduce unwanted impurities in the underlying organic active layers. And also, sputtering of inorganic metal oxides may damage the underlying organic semiconductors. Here, we demonstrated that by utilizing vacuum evaporated lithium fluoride (LiF) as protective buffer layer, spin-coated insulating polymer polyvinyl alcohol (PVA), and sputtered inorganic material Er2O3, can be successfully applied for thin film encapsulation of copper phthalocyanine (CuPc)-based organic diodes. By encapsulating with LiF/PVA/LiF trilayer and LiF/Er2O3 bilayer films, the device lifetime improvements of 10 and 15 times can be achieved. These methods should be applicable for thin-film encapsulation of all kinds of organic electronic devices. Moisture-induced hole trapping, and Al top electrode oxidation are suggest to be the origins of current decay for the LiF/PVA/LiF trilayer and LiF/Er2O3 bilayer films encapsulated devices, respectively.

  7. Assessment of three-dimensional set-up errors in conventional head and neck radiotherapy using electronic portal imaging device

    International Nuclear Information System (INIS)

    Gupta, Tejpal; Chopra, Supriya; Kadam, Avinash; Agarwal, Jai Prakash; Devi, P Reena; Ghosh-Laskar, Sarbani; Dinshaw, Ketayun Ardeshir

    2007-01-01

    Set-up errors are an inherent part of radiation treatment process. Coverage of target volume is a direct function of set-up margins, which should be optimized to prevent inadvertent irradiation of adjacent normal tissues. The aim of this study was to evaluate three-dimensional (3D) set-up errors and propose optimum margins for target volume coverage in head and neck radiotherapy. The dataset consisted of 93 pairs of orthogonal simulator and corresponding portal images on which 558 point positions were measured to calculate translational displacement in 25 patients undergoing conventional head and neck radiotherapy with antero-lateral wedge pair technique. Mean displacements, population systematic (Σ) and random (σ) errors and 3D vector of displacement was calculated. Set-up margins were calculated using published margin recipes. The mean displacement in antero-posterior (AP), medio-lateral (ML) and supero-inferior (SI) direction was -0.25 mm (-6.50 to +7.70 mm), -0.48 mm (-5.50 to +7.80 mm) and +0.45 mm (-7.30 to +7.40 mm) respectively. Ninety three percent of the displacements were within 5 mm in all three cardinal directions. Population systematic (Σ) and random errors (σ) were 0.96, 0.98 and 1.20 mm and 1.94, 1.97 and 2.48 mm in AP, ML and SI direction respectively. The mean 3D vector of displacement was 3.84 cm. Using van Herk's formula, the clinical target volume to planning target volume margins were 3.76, 3.83 and 4.74 mm in AP, ML and SI direction respectively. The present study report compares well with published set-up error data relevant to head and neck radiotherapy practice. The set-up margins were <5 mm in all directions. Caution is warranted against adopting generic margin recipes as different margin generating recipes lead to a different probability of target volume coverage

  8. Protecting computer-based medical devices: defending against viruses and other threats.

    Science.gov (United States)

    2005-07-01

    The increasing integration of computer hardware has exposed medical devices to greater risks than ever before. More and more devices rely on commercial off-the-shelf software and operating systems, which are vulnerable to the increasing proliferation of viruses and other malicious programs that target computers. Therefore, it is necessary for hospitals to take steps such as those outlined in this article to ensure that their computer-based devices are made safe and continue to remain safe in the future. Maintaining the security of medical devices requires planning, careful execution, and a commitment of resources. A team should be created to develop a process for surveying the security status of all computerized devices in the hospital and making sure that patches and other updates are applied as needed. These patches and updates should be approved by the medical system supplier before being implemented. The team should consider using virtual local area networks to isolate susceptible devices on the hospital's network. All security measures should be carefully documented, and the documentation should be kept up-to-date. Above all, care must be taken to ensure that medical device security involves a collaborative, supportive partnership between the hospital's information technology staff and biomedical engineering personnel.

  9. 11 June 2012 - Austrian Federal Minister of Labour, Social Affairs and Consumer Protection R. Hundstorfer signing the guest book with Head of International Relations F. Pauss and Ambassador to the UN C. Strohal (CERN-HI-120611334)

    CERN Multimedia

    2012-01-01

    11 June 2012 - Austrian Federal Minister of Labour, Social Affairs and Consumer Protection R. Hundstorfer signing the guest book with Head of International Relations F. Pauss and Ambassador to the UN C. Strohal (CERN-HI-120611334)

  10. Breath-hold monitoring and visual feedback for radiotherapy using a charge-coupled device camera and a head-mounted display. System development and feasibility

    International Nuclear Information System (INIS)

    Yoshitake, Tadamasa; Nakamura, Katsumasa; Shioyama, Yoshiyuki

    2008-01-01

    The aim of this study was to present the technical aspects of the breath-hold technique with respiratory monitoring and visual feedback and to evaluate the feasibility of this system in healthy volunteers. To monitor respiration, the vertical position of the fiducial marker placed on the patient's abdomen was tracked by a machine vision system with a charge-coupled device camera. A monocular head-mounted display was used to provide the patient with visual feedback about the breathing trace. Five healthy male volunteers were enrolled in this study. They held their breath at the end-inspiration and the end-expiration phases. They performed five repetitions of the same type of 15-s breath-holds with and without a head-mounted display, respectively. A standard deviation of five mean positions of the fiducial marker during a 15-s breath-hold in each breath-hold type was used as the reproducibility value of breath-hold. All five volunteers well tolerated the breath-hold maneuver. For the inspiration breath-hold, the standard deviations with and without visual feedback were 1.74 mm and 0.84 mm, respectively (P=0.20). For the expiration breath-hold, the standard deviations with and without visual feedback were 0.63 mm and 0.96 mm, respectively (P=0.025). Our newly developed system might help the patient achieve improved breath-hold reproducibility. (author)

  11. Efficient Protection of Android Applications through User Authentication Using Peripheral Devices

    OpenAIRE

    Jinseong Kim; Im Y. Jung

    2018-01-01

    Android applications store large amounts of sensitive information that may be exposed and exploited. To prevent this security risk, some applications such as Syrup and KakaoTalk use physical device values to authenticate or encrypt application data. However, by manipulating these physical device values, an attacker can circumvent the authentication by executing a Same Identifier Attack and obtain the same application privileges as the user. In our work, WhatsApp, KakaoTalk, Facebook, Amazon, ...

  12. A feasibility and efficacy trial of a hand-held humidification device in patients undergoing radiotherapy for head and neck cancer.

    Science.gov (United States)

    Ghosh, Priyanka; Lazar, Ann A; Ryan, William R; Yom, Sue S

    2017-08-01

    This study aimed to evaluate the effects of warm-mist humidification during and after head and neck radiation therapy (HN RT) on quality of life (QOL), as measured by the M. D. Anderson Symptom Inventory-Head and Neck (MDASI-HN) HN score. A secondary aim was to compare QOL among compliers (≥60% of protocol-recommended usage) versus non-compliers. Twenty patients self-administered a hand-held, self-sterilizing humidification device for a recommended time of at least 15 min twice daily for 12 weeks. Patients completed the MDASI-HN instrument at RT start, after 6 weeks, and after 12 weeks. Compliance was reported weekly. The average HN score at baseline was 1.7 (SD = 1.8) and increased to 6.0 (SD = 1.6) after 6 weeks; this increase was much higher than anticipated and the primary endpoint could not be reached. However, compliers had an average of nearly two less HN symptoms (-1.8, 95% CI -4 to 0.2; p = 0.08) than non-compliers at 6 weeks and fewer symptoms at 12 weeks as well (-0.9, 95% CI -2.9 to 1.2; p = 0.39). The most common terms patients used to describe humidification were "helpful" and "soothing." Compliance with humidification during RT was associated with fewer reported HN symptoms and a strong trend to better QOL. Improvements were seen from compliance with occasional required use of a portable, inexpensive device. Our findings support continued efforts to reduce barriers to humidification, as an intervention that should be considered for standard HN RT clinical practice.

  13. 30 CFR 77.802 - Protection of high-voltage circuits; neutral grounding resistors; disconnecting devices.

    Science.gov (United States)

    2010-07-01

    ... AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES Surface High-Voltage Distribution § 77.802 Protection... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Protection of high-voltage circuits; neutral... grounded through a suitable resistor at the source transformers, and a grounding circuit, originating at...

  14. Reliability of microprocessor-based relay protection devices: Myths and reality

    Directory of Open Access Journals (Sweden)

    Gurevich Vladimir

    2009-01-01

    Full Text Available The article examines four basic theses about the ostensibly extremely high reliability of microprocessor-based relay protection (MP touted by supporters of MP. Through detailed analysis based on many references it is shown that the basis of these theses are widespread myths, and actually MP reliability is lower than the reliability of electromechanical and electronic protective relays on discrete components.

  15. Electric protection of the ion sources of the Ogra-4 device

    International Nuclear Information System (INIS)

    Matveev, N.V.; Obysov, V.A.

    1984-01-01

    Electric circuit of an ion source power supply comprising elements for protection from damages in case of discharges inside the source, has been described. The possibility of protection against discharge and subsequent reclosing switching of the ion source using consecutive protective key element in the circuit of power supply emission electrode, electron commutator being used as one, has been studied. Results of the use of commutators on the basis of electron-beam valves as the main commutating element are presented. Application of the circuit described permitted to achieve voltage restoration on the ion source electrodes when the valve reclosing switching time delay constituted 200 μs

  16. A Wireless Swing Angle Measurement Scheme Using Attitude Heading Reference System Sensing Units Based on Microelectromechanical Devices

    Directory of Open Access Journals (Sweden)

    Bingtuan Gao

    2014-11-01

    Full Text Available Feasible real-time swing angle measurement is significant to improve the efficiency and safety of industrial crane systems. This paper presents a wireless microelectromechanical system (MEMS-based swing angle measurement system. The system consists of two attitude heading reference system (AHRS sensing units with a wireless communication function, which are mounted on the hook (or payload and the jib (or base of the crane, respectively. With a combination of a three-axis accelerometer, a three-axis gyroscope and a three-axis magnetometer, the standard extended Kalman filter (EKF is used to estimate the desired orientation of the payload and the base. Wireless ZigBee communication is employed to transmit the orientation of the payload to the sensing unit mounted on the base, which measures the orientation of the base. Because several physical parameters from the payload to the base can be acquired from the original crane control system, the swing angles of the payload can be calculated based on the two measured orientation parameters together with the known physical parameters. Experiments were performed to show the feasibility and effectiveness of the proposed swing angle measurement system.

  17. Location Privacy Protection Based on Improved K-Value Method in Augmented Reality on Mobile Devices

    Directory of Open Access Journals (Sweden)

    Chunyong Yin

    2017-01-01

    Full Text Available With the development of Augmented Reality technology, the application of location based service (LBS is more and more popular, which provides enormous convenience to people’s life. User location information could be obtained at anytime and anywhere. So user location privacy security suffers huge threats. Therefore, it is crucial to pay attention to location privacy protection in LBS. Based on the architecture of the trusted third party (TTP, we analyzed the advantages and shortages of existing location privacy protection methods in LBS on mobile terminal. Then we proposed the improved K-value location privacy protection method according to privacy level, which combines k-anonymity method with pseudonym method. Through the simulation experiment, the results show that this improved method can anonymize all service requests effectively. In addition to the experiment of execution time, it demonstrated that our proposed method can realize the location privacy protection more efficiently.

  18. Evaluation of personal protective devices used in diagnostic radiology; Avaliacao de dispositivos de protecao individual utilizados em radiologia diagnostica

    Energy Technology Data Exchange (ETDEWEB)

    Soares, Fernanda Cristina Salvador

    2006-07-01

    In this work protective devices of five manufacturers were evaluated according to the NBR/IEC 61331-1 and NBR/IEC 61331-3 standards. Three different methodologies (linear interpolation, Archer model and sum of exponentials) were applied for the determination of the attenuation equivalent, since the standard does not indicate how it must be determined. Moreover, the uncertainties associated to each method, and the influence of the number of measurements in the combined uncertainty were estimated. The evaluated manufacture characteristics were: accompanying document, design, materials, dimensions and label marking. For this evaluation a check list about the requirements of the NBR/IEC 61331-3 standard was elaborated. The results showed a great difference between nominal and measured attenuation equivalent values. The comparison of the results using the three methodologies showed small variations among the obtained values and among the associated uncertainties in the different methodologies. It was possible to observe that the number of measurements does not contribute significantly for the increase of the uncertainty in all three methodologies. The best methodology for the laboratory routine is the linear interpolation methodology, with five measurements for each air kerma rate value. The discrepancy between the results obtained in this work and the requirements of the applied standards show the need to adopt a compulsory certification process for protective devices, thus contributing for the increase of the radiation protection of the users. (author)

  19. AntibIoTic: Protecting IoT Devices Against DDoS Attacks

    DEFF Research Database (Denmark)

    De Donno, Michele; Dragoni, Nicola; Giaretta, Alberto

    2018-01-01

    The 2016 is remembered as the year that showed to the world how dangerous Distributed Denial of Service attacks can be. Gauge of the disruptiveness of DDoS attacks is the number of bots involved: the bigger the botnet, the more powerful the attack. This character, along with the increasing...... availability of connected and insecure IoT devices, makes DDoS and IoT the perfect pair for the malware industry. In this paper we present the main idea behind AntibIoTic, a palliative solution to prevent DDoS attacks perpetrated through IoT devices....

  20. Enabling GPU-assisted Antivirus Protection on Android Devices Through Edge Offloading

    DEFF Research Database (Denmark)

    Deyannis, Dimitris; Tsirbas, Rafail; Vasiliadis, Giorgos

    2018-01-01

    Antivirus software are the most popular tools for detecting and stopping malicious or unwanted files. However, the performance requirements of traditional host-based antivirus make their wide adoption to mobile, embedded, and hand-held devices questionable. Their computational- and memory...

  1. Thermal protection of electronic devices with the Nylon6/66-PEG nanofiber membranes

    OpenAIRE

    Li Ya; Li Xue-Weis; He Ji-Huan; Wang Ping

    2014-01-01

    Phase change materials for thermal energy storage have been widely applied to clothing insulation, electronic products of heat energy storage. The thermal storage potential of the nanofiber membranes was analyzed using the differential scanning calorimetry. Effect of microstructure of the membrane on energy storage was analyzed, and its applications to electronic devices were elucidated.

  2. Protection of stapled colorectal anastomoses with a biodegradable device : the C-Seal feasibility study

    NARCIS (Netherlands)

    Kolkert, Joe L.; Havenga, Klaas; Hoedemaker, Henk O. ten Cate; Zuidema, Johan; Ploeg, Rutger J.

    BACKGROUND: A colorectal anastomotic leak can be life-threatening. We have assessed the feasibility of a new intraluminal biodegradable bypass device that we designed to avoid anastomotic leakage and the necessity of a temporary stoma. METHODS: Fifteen patients underwent colorectal surgery. Before

  3. Multiobjective optimal placement of switches and protective devices in electric power distribution systems using ant colony optimization

    Energy Technology Data Exchange (ETDEWEB)

    Tippachon, Wiwat; Rerkpreedapong, Dulpichet [Department of Electrical Engineering, Kasetsart University, 50 Phaholyothin Rd., Ladyao, Jatujak, Bangkok 10900 (Thailand)

    2009-07-15

    This paper presents a multiobjective optimization methodology to optimally place switches and protective devices in electric power distribution networks. Identifying the type and location of them is a combinatorial optimization problem described by a nonlinear and nondifferential function. The multiobjective ant colony optimization (MACO) has been applied to this problem to minimize the total cost while simultaneously minimize two distribution network reliability indices including system average interruption frequency index (SAIFI) and system interruption duration index (SAIDI). Actual distribution feeders are used in the tests, and test results have shown that the algorithm can determine the set of optimal nondominated solutions. It allows the utility to obtain the optimal type and location of devices to achieve the best system reliability with the lowest cost. (author)

  4. Overcurrent protection co-ordination: A modern approach for modern devices

    Energy Technology Data Exchange (ETDEWEB)

    Hindle, P.J.

    1995-12-31

    The increasing densities and reduced geographical spans of urban and industrial power systems call for the coordination of more stages of overcurrent protection up to increasingly high fault levels. Applying existing rules of relay coordination, especially for industrial power systems, may make achieving satisfactory coordination difficult. This paper proposes a modern approach to coordination which is able to take advantage of the improved performance of modern protective relays and circuit breakers. The proposed method can handle a mix of new and old equipment and is made most useful when implemented with commonly available spreadsheet software. The suggested approach justifies reduced time margins for relay coordination in many difficult applications. Example calculations are included to illustrate typical considerations for coordinating two digital protection relays where a vacuum circuit breaker is used to clear a downstream fault.

  5. Diffusion-weighted magnetic resonance imaging in carotid angioplasty and stenting with balloon embolic protection devices

    International Nuclear Information System (INIS)

    Asakura, Fumio; Kawaguchi, Kenji; Sakaida, Hiroshi; Toma, Naoki; Matsushima, Satoshi; Kuraishi, Keita; Tanemura, Hiroshi; Miura, Yoichi; Taki, Waro; Maeda, Masayuki

    2006-01-01

    We compared the results of two procedures to protect against distal embolism caused by embolic debris from carotid angioplasty with stent deployment (CAS) using diffusion-weighted magnetic resonance imaging (MRI). The study group comprised 39 men and 3 women (42 and 3 CAS procedures, respectively) with severe carotid stenosis (average age 70.0±6.6 years). During 20 CAS procedures the internal carotid artery was protected with a single balloon. A PercuSurge GuardWire was used for temporary occlusion. During 25 CAS procedures the internal and external carotid arteries were simultaneously temporarily occluded with a PercuSurge GuardWire and a Sentry balloon catheter, respectively. Diffusion-weighted MRI was performed 1 to 3 days after CAS. Data from 26 patients undergoing conventional angiography for diagnosis of cerebral ischemic disease, cerebral aneurysm or brain tumors were included as controls. Diffusion-weighted MRI after conventional diagnostic angiography showed ischemic spots in 3 of the 26 controls (11.5%). Ischemic spots were observed during 11 of 20 CAS procedures with the internal carotid artery protected with a single balloon (55.0%), and were observed during 9 of 25 CAS procedures with both the internal and external carotid arteries protected (36.0%). This difference was significant (P=0.0068). Ischemic lesions appeared not only ipsilateral to the carotid stenosis but also in the contralateral carotid artery (31.9%) and vertebrobasilar territory (25.3%). Better protection was obtained with simultaneous double occlusion of both the internal and external carotid artery than with single protection of the internal carotid artery during CAS. (orig.)

  6. Definition and production of calibration standard neutron sources for radiation protection device calibration

    International Nuclear Information System (INIS)

    De Matos, E.

    1987-01-01

    To improve the characterization of radioprotection devices performances, it would be advisable to calibrate these devices in neutron spectra which are nearly like those met in practice (nuclear reactors, plutonium technology laboratories...). The purpose of this work is, in a first time, to choose the nature and the dimensions of the different shields used to achieve broad typical neutron spectra extending to lower energies from a 14.8 MeV neutron beam. The second step is the evaluation of spectral distribution and calculation of associated dosimetric quantities. For that, several spectrometric techniques are employed: on one hand, activation detectors and Bonner spheres method named rough spectrometry; on the other hand, an accurate spectrometry which uses recoil proton counters. The dosimetric quantities, especially the value of kerma deduced from these spectra must be in good agreement with those measured with a tissue equivalent ionization chamber [fr

  7. Ionizing secondary radiation generated by analog radiological and digital coronary cine angiographic equipment. Influence of external protection devices

    International Nuclear Information System (INIS)

    Ramirez N, Alfredo; Farias Ch, Eric; Silva J, Ana Maria; Leyton L, Fernando; Oyarzun C, Carlos; Ugalde P, Hector; Dussaillant, Gaston; Cumsille G, Angel

    2000-01-01

    Exposure to ionizing radiation is a know hazard of radiological procedures. Aim: to compare the emission of secondary ionizing radiation from two coronary angiographic equipments, one with digital and the other with analog image generation. To evaluate the effectiveness of external radiological protection devices. Material and methods: environmental and fluoroscopy generated radiation in the cephalic region of the patient was measured during diagnostic coronary angiographies. Ionizing radiation generated in anterior left oblique protection (ALO) and anterior right oblique protection (ARO) were measured with and without leaded protections. In 19 patients (group 1), a digital equipment was used and in 21 (group 2), an analog equipment. Results: header radiation for group 1 and 2 was 1194±337 and 364±222 μGray/h respectively (p≤0.001). During fluoroscopy and with leaded protection generated radiation for groups 1 and 2 was 612±947 and 70±61μGray/h respectively (p≤0.001). For ALO projection, generated for groups 1 and 2 was 105±47 and 71±192 μGray/h respectively (p≤0.001). During filming the radiation for ALO projection for groups 1 and 2 was 7252±9569 and 1671±2038 μGray/h respectively (p=0.03). Out of the protection zone, registered radiation during fluoroscopy for groups 1 and 2 was 2800±1741 and 1318±954 μGray/h respectively (p≤0.001); during filming, the figures were 15500±5840 and 18961±10599 μGray/h respectively (NS). Conclusions: digital radiological equipment has a lower level of ionizing radiation emission than the analog equipment

  8. Perspective pulse devices and automatic systems fire explosive protection of the radioactive infected objects

    International Nuclear Information System (INIS)

    Zakhmatov, V.D.; Kozhemyakin, A.S.; Pyatova, A.V.

    1999-01-01

    The suppression of fires in Chernobyl zone has shown complete unprofitable of traditional fire engineering to work on is radioactive of the infected district. In this connection as effective ways extinguishive in object 'Shelter' alongside with known traditional means and the systems offer to apply more perspective pulse systems, based on use energy small practically safe charges of gunpowder or explosive substances, in particular. Pulse explosive cone extinguishive of the device various sizes

  9. Process and device for the protection of steam-raising units, particularly of nuclear reactors

    International Nuclear Information System (INIS)

    Beyer, W.; Wieling, N.; Stellwag, B.

    1986-01-01

    To protect the housing against corrosion by chemical conditioning of the feedwater, the redox potential of the feedwater and the corrosion potential of at least one pipe of the pipe bundle is continuously determined during operation of the steam raising unit. With potentials indicating the danger of corrosion, the quality of the secondary water can be improved by suitable measures. (orig./HP) [de

  10. Improvements in or relating to the protection of thermoelectric devices against shocks and accelerations

    International Nuclear Information System (INIS)

    Brown, M.H.; Myatt, J.

    1979-01-01

    Heart pacemakers are protected against shock and acceleration by surrounding the heat source, but not in contact with the source or the thermoelectric unit, with a plurity of spring fingers. These arrest the radioactive source in the event of movement on its resilient mounting of the thermoelectric unit relative to the casing in excess of a predetermined amount. (UK)

  11. Efficient Protection of Android Applications through User Authentication Using Peripheral Devices

    Directory of Open Access Journals (Sweden)

    Jinseong Kim

    2018-04-01

    Full Text Available Android applications store large amounts of sensitive information that may be exposed and exploited. To prevent this security risk, some applications such as Syrup and KakaoTalk use physical device values to authenticate or encrypt application data. However, by manipulating these physical device values, an attacker can circumvent the authentication by executing a Same Identifier Attack and obtain the same application privileges as the user. In our work, WhatsApp, KakaoTalk, Facebook, Amazon, and Syrup were subjected to the Same Identifier Attack, and it was found that an attacker could gain the same privileges as the user, in all five applications. To solve such a problem, we propose a technical scheme—User Authentication using Peripheral Devices. We applied the proposed scheme to a Nexus 5X smartphone running Android version 7.1 and confirmed that the average execution time was 0.005 s, which does not affect the other applications’ execution significantly. We also describe the security aspects of the proposed scheme and its compatibility with the Android platform and other applications. The proposed scheme is practical and efficient in terms of resource usage; therefore, it will be useful for Android users to improve Android application security.

  12. Comparison of performance of three different types of respiratory protection devices.

    Science.gov (United States)

    Lawrence, Robert B; Duling, Matthew G; Calvert, Catherine A; Coffey, Christopher C

    2006-09-01

    Respiratory protection is offered to American workers in a variety of ways to guard against potential inhalation hazards. Two of the most common ways are elastomeric N95 respirators and N95 filtering-facepiece respirators. Some in the health care industry feel that surgical masks provide an acceptable level of protection in certain situations against particular hazards. This study compared the performance of these types of respiratory protection during a simulated workplace test that measured both filter penetration and face-seal leakage. A panel of 25 test subjects with varying face sizes tested 15 models of elastomeric N95 respirators, 15 models of N95 filtering-facepiece respirators, and 6 models of surgical masks. Simulated workplace testing was conducted using a TSI PORTACOUNT Plus model 8020, and consisted of a series of seven exercises. Six simulated workplace tests were performed with redonning of the respirator/mask occurring between each test. The results of these tests produced a simulated workplace protection factor (SWPF). The geometric mean (GM) and the 5th percentile values of the SWPFs were computed by category of respiratory protection using the six overall SWPF values. The level of protection provided by each of the three respiratory protection types was compared. The GM and 5th percentile SWPF values without fit testing were used for the comparison, as surgical masks were not intended to be fit tested. The GM values were 36 for elastomeric N95 respirators, 21 for N95 filtering-facepiece respirators, and 3 for surgical masks. An analysis of variance demonstrated a statistically significant difference between all three. Elastomeric N95 respirators had the highest 5th percentile SWPF of 7. N95 filtering-facepiece respirators and surgical masks had 5th percentile SWPFs of 3 and 1, respectively. A Fisher Exact Test revealed that the 5th percentile SWPFs for all three types of respiratory protection were statistically different. In addition, both

  13. Balancing protection of public health and safety with the free movement of goods in the EU medical device sector : The case of ‘borderline products’ classification

    NARCIS (Netherlands)

    Tseliou, Tasoula

    2015-01-01

    In 2013, the CJEU ruled on the ‘Lyocentre’ case touching upon an important and contemporary issue in the EU Medical Device regime – the classification issue between medical devices and medicinal products. This problem is connected with the internal market v. protection of health dilemma as well as

  14. Reference neutron radiations. Part 2: Calibration fundamentals of radiation protection devices related to the basic quantities characterizing the radiation field

    International Nuclear Information System (INIS)

    2000-01-01

    ISO 8529 consists of the following parts, under the general title Reference neutron radiations: Part 1: Characteristics and methods of production; Part 2: Calibration fundamentals of radiation protection devices related to the basic quantities characterizing the radiation field; Part 3: Calibration of area and personal dosimeters and determination of response as a function of energy and angle of incidence. This Part 2. of ISO 8529 takes as its starting point the neutron sources described in ISO 8529-1. It specifies the procedures to be used for realizing the calibration conditions of radiation protection devices in neutron fields produced by these calibration sources, with particular emphasis on the corrections for extraneous effects (e.g., the neutrons scattered from the walls of the calibration room). In this part of ISO 8529, particular emphasis is placed on calibrations using radionuclide sources (clauses 4 to 6) due to their widespread application, with less details given on the use of accelerator and reactor sources (8.2 and 8.3). This part of ISO 8529 then leads to ISO 8529-3 which gives conversion coefficients and the general rules and procedures for calibration

  15. 21 CFR 868.1930 - Stethoscope head.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Stethoscope head. 868.1930 Section 868.1930 Food... DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1930 Stethoscope head. (a) Identification. A stethoscope head is a weighted chest piece used during anesthesia to listen to a patient's heart, breath, and...

  16. Operating devices for radiation protection: acceptable deviations from legal metrology point of view

    International Nuclear Information System (INIS)

    Soukup, T.

    2008-01-01

    The objective of this paper is to draw attention to possible discrepancies in the measuring the quantities of ionizing radiation mainly in natural environment, that cannot be explained by faulty gauges. In addition I would like to draw the attention to these issue radiation protection researchers, document that uncertainties in estimating the impact of exposure and transfer them into the language of used meters tolerances. (authors)

  17. Preparation and thermal performance of paraffin/Nano-SiO2 nanocomposite for passive thermal protection of electronic devices

    International Nuclear Information System (INIS)

    Wang, Yaqin; Gao, Xuenong; Chen, Peng; Huang, Zhaowen; Xu, Tao; Fang, Yutang; Zhang, Zhengguo

    2016-01-01

    Highlights: • Three types of paraffin/nano-SiO 2 nanocomposites were prepared and characterized. • Thermo-physical properties of these composites were determined and compared. • One composite with lower thermal conductivity showed better thermal insulation properties. • This composite was identified as thermal insulation material for electronic components. - Abstract: In this paper, three grades of nano silicon dioxide (nano-SiO 2 ), NS1, NS2 and NS3, were mixed into paraffin to prepare nanocomposites as novel insulation materials for electronic passive thermal protection applications. The optimal mass percentages of paraffin for the three composites, NS1P, NS2P and NS3P, were determined to be 75%, 70% and 65%, respectively. Investigations by means of scanning electron micrographs (SEM), differential scanning calorimeter (DSC), thermogravimetric analysis (TG), hot disk analyzer and thermal protection performance tests were devoted to the morphology, thermal properties and thermal protection performance analysis of composites. Experimental results showed that paraffin uniformly distributed into the pores and on the surface of nano-SiO 2 . Melting points of composites declined and experimental latent heat became lower than the calculated values with the decrease of nano-SiO 2 pore size. The NS1P composite had larger thermal storage capacity, better reliability and stability compared with NS2P and NS3P. In addition, compared with 90% wt.% paraffin/EG composite, the incorporation of NS1 (25 wt.%) into paraffin caused not only 63.2% reduction in thermal conductivity, but also 21.8% increase in thermal protection time affected by the ambient temperature. Thus those good properties confirmed that NS1P (75 wt.%) composite was a viable candidate for protecting electronic devices under high temperature environment.

  18. SU-E-T-570: Management of Radiation Oncology Patients with Cochlear Implant and Other Bionic Devices in the Brain and Head and Neck Regions

    Energy Technology Data Exchange (ETDEWEB)

    Guo, F.Q; Chen, Z; Nath, R [Yale New Haven Hospital, New Haven, CT (United States); Yale UniversitySchool of Medicine, New Haven, CT (United States)

    2014-06-01

    Purpose: To investigate the current status of clinical usage of cochlear implant (CI) and other bionic devices (BD) in the brain and head and neck regions (BH and N) and their management in patients during radiotherapy to ensure patient health and safety as well as optimum radiation delivery. Methods: Literature review was performed with both CIs and radiotherapy and their variants as keywords in PubMed, INSPEC and other sources. The focus was on CIs during radiotherapy, but it also included other BDs in BHȦN, such as auditory brainstem implant, bionic retinal implant, and hearing aids, among others. Results: Interactions between CIs and radiation may cause CIs malfunction. The presence of CIs may also cause suboptimum dose distribution if a treatment plan was not well designed. A few studies were performed for the hearing functions of CIs under irradiations of 4 MV and 6 MV x-rays. However, x-rays with higher energies (10 to 18 MV) broadly used in radiotherapy have not been explored. These higher energetic beams are more damaging to electronics due to strong penetrating power and also due to neutrons generated in the treatment process. Modern CIs are designed with more and more complicated integrated circuits, which may be more susceptible to radiation damage and malfunction. Therefore, careful management is important for safety and treatment outcomes. Conclusion: Although AAPM TG-34, TG-63, and TG-203 (update of TG-34, not published yet) reports may be referenced for management of CIs and other BDs in the brain and H and N regions, a site- and device-specified guideline should be developed for CIs and other BDs. Additional evaluation of CI functions under clinically relevant set-ups should also be performed to provide clinicians with better knowledge in clinical decision making.

  19. Toll-like Receptor 5 Agonist Protects Mice From Dermatitis and Oral Mucositis Caused by Local Radiation: Implications for Head-and-Neck Cancer Radiotherapy

    International Nuclear Information System (INIS)

    Burdelya, Lyudmila G.; Gleiberman, Anatoli S.; Toshkov, Ilia; Aygun-Sunar, Semra; Bapardekar, Meghana; Manderscheid-Kern, Patricia; Bellnier, David; Krivokrysenko, Vadim I.; Feinstein, Elena; Gudkov, Andrei V.

    2012-01-01

    Purpose: Development of mucositis is a frequent side effect of radiotherapy of patients with head-and-neck cancer. We have recently reported that bacterial flagellin, an agonist of Toll-like receptor 5 (TLR5), can protect rodents and primates from acute radiation syndrome caused by total body irradiation. Here we analyzed the radioprotective efficacy of TLR5 agonist under conditions of local, single dose or fractionated radiation treatment. Methods and Materials: Mice received either single-dose (10, 15, 20, or 25 Gy) or fractioned irradiation (cumulative dose up to 30 Gy) of the head-and-neck area with or without subcutaneous injection of pharmacologically optimized flagellin, CBLB502, 30 min before irradiation. Results: CBLB502 significantly reduced the severity of dermatitis and mucositis, accelerated tissue recovery, and reduced the extent of radiation induced weight loss in mice after a single dose of 15 or 20 Gy but not 25 Gy of radiation. CBLB502 was also protective from cumulative doses of 25 and 30 Gy delivered in two (10 + 15 Gy) or three (3 × 10 Gy) fractions, respectively. While providing protection to normal epithelia, CBLB502 did not affect the radiosensitivity of syngeneic squamous carcinoma SCCVII grown orthotopically in mice. Use of CBLB502 also elicited a radiation independent growth inhibitory effect upon TLR5-expressing tumors demonstrated in the mouse xenograft model of human lung adenocarcinoma A549. Conclusion: CBLB502 combines properties of supportive care (radiotherapy adjuvant) and anticancer agent, both mediated via activation of TLR5 signaling in the normal tissues or the tumor, respectively.

  20. Toll-like Receptor 5 Agonist Protects Mice From Dermatitis and Oral Mucositis Caused by Local Radiation: Implications for Head-and-Neck Cancer Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Burdelya, Lyudmila G. [Department of Cell Stress Biology, Roswell Park Cancer Institute, Buffalo, NY (United States); Gleiberman, Anatoli S.; Toshkov, Ilia [Cleveland BioLabs, Inc., Buffalo, NY (United States); Aygun-Sunar, Semra [Department of Cell Stress Biology, Roswell Park Cancer Institute, Buffalo, NY (United States); Bapardekar, Meghana [Cleveland BioLabs, Inc., Buffalo, NY (United States); Manderscheid-Kern, Patricia; Bellnier, David [Department of Cell Stress Biology, Roswell Park Cancer Institute, Buffalo, NY (United States); Krivokrysenko, Vadim I.; Feinstein, Elena [Cleveland BioLabs, Inc., Buffalo, NY (United States); Gudkov, Andrei V., E-mail: andrei.gudkov@roswellpark.org [Department of Cell Stress Biology, Roswell Park Cancer Institute, Buffalo, NY (United States); Cleveland BioLabs, Inc., Buffalo, NY (United States)

    2012-05-01

    Purpose: Development of mucositis is a frequent side effect of radiotherapy of patients with head-and-neck cancer. We have recently reported that bacterial flagellin, an agonist of Toll-like receptor 5 (TLR5), can protect rodents and primates from acute radiation syndrome caused by total body irradiation. Here we analyzed the radioprotective efficacy of TLR5 agonist under conditions of local, single dose or fractionated radiation treatment. Methods and Materials: Mice received either single-dose (10, 15, 20, or 25 Gy) or fractioned irradiation (cumulative dose up to 30 Gy) of the head-and-neck area with or without subcutaneous injection of pharmacologically optimized flagellin, CBLB502, 30 min before irradiation. Results: CBLB502 significantly reduced the severity of dermatitis and mucositis, accelerated tissue recovery, and reduced the extent of radiation induced weight loss in mice after a single dose of 15 or 20 Gy but not 25 Gy of radiation. CBLB502 was also protective from cumulative doses of 25 and 30 Gy delivered in two (10 + 15 Gy) or three (3 Multiplication-Sign 10 Gy) fractions, respectively. While providing protection to normal epithelia, CBLB502 did not affect the radiosensitivity of syngeneic squamous carcinoma SCCVII grown orthotopically in mice. Use of CBLB502 also elicited a radiation independent growth inhibitory effect upon TLR5-expressing tumors demonstrated in the mouse xenograft model of human lung adenocarcinoma A549. Conclusion: CBLB502 combines properties of supportive care (radiotherapy adjuvant) and anticancer agent, both mediated via activation of TLR5 signaling in the normal tissues or the tumor, respectively.

  1. Exploiting heat treatment effects on SMAs macro and microscopic properties in developing fire protection devices

    Science.gov (United States)

    Burlacu, L.; Cimpoeşu, N.; Bujoreanu, L. G.; Lohan, N. M.

    2017-08-01

    Ni-Ti shape memory alloys (SMAs) are intelligent alloys which demonstrate unique properties, such as shape memory effect, two-way shape memory effect, super-elasticity and vibration damping which, accompanied by good processability, excellent corrosion resistance and biocompatibility as well as fair wear resistance and cyclic stability, enabled the development of important industrial applications (such as sensors, actuators, fasteners, couplings and valves), medical applications (such as stents, bone implants, orthodontic archwires, minimal invasive surgical equipment) as well as environmental health and safety devices (anti-seismic dampers, fire safety devices). The phase transitions in Ni-Ti SMAs are strongly influenced by processing methods, chemical compositions and thermomechanical history. This paper presents a study of the effects of heat treatment on the mechanical and thermal properties of commercial Ni-Ti shape memory alloy (SMA). The experimental work involved subjecting a SMA rod to heat-treatment consisting in heating up to 500°C, 10 minutes-maintaining and water quenching. Mechanical properties were highlighted by microhardness tests while thermal characteristics were emphasized by differential scanning calorimetry (DSC). The presence of chemical composition fluctuations was checked by X-ray energy dispersive spectroscopy performed with an EDAX Bruker analyzer.

  2. Heads Up

    Science.gov (United States)

    ... Connect with Us HEADS UP Apps Reshaping the Culture Around Concussion in Sports Get HEADS UP on Your Web Site Concussion ... HEADS UP on your web site! Create a culture of safety for young athletes Officials, learn how you can ... UP to Providers HEADS UP to Youth Sports HEADS UP to School Sports HEADS UP to ...

  3. Overcurrent protection co-ordination. A modern approach for modern devices

    Energy Technology Data Exchange (ETDEWEB)

    Hindle, P. [GEC Alsthom Engineering Systems Ltd., Whetstone (United Kingdom); Sanderson, J.V.H. [Power Engineering Consultants Ltd., Cheshire (United Kingdom)

    1995-12-31

    A modern approach to relay co-ordination that takes advantage of the improved performance of modern protective relays and circuits was proposed. The proposed method dealt with a mixture of new and old equipment and was most useful when implemented using common spreadsheet software. The suggested approach justified reduced time margins for relay co-ordination in many difficult applications. Other established approaches were reviewed. A discussion of fixed and variable time margin allowances was presented. The formulation of an equation to determine the required upstream relay operating time was explained, with sample calculations. Relay performance standards and modern protective equipment were discussed. It was concluded that modern relays and circuit breakers are much more advanced than designs of the recent past. The method described allowed significant reductions in margins which enabled modern relays to operate faster. While calculations for the procedures were said to be tedious to perform by hand, they can be easily done with spreadsheet software. 10 refs., 4 figs.

  4. Analysis of the network protection devices action connected with the Krsko NPP operation safety

    International Nuclear Information System (INIS)

    Omahen, P.; Struc, S.

    1995-01-01

    The example of failure that took place in Zagreb on 30 March, 1995, has been investigated in order to obtain appropriate answers to the unexpected electric power system (ESP) response and consecutive outage of the Krsko nuclear power plant (NPP). The analysis has been made of particular operating and stability conditions, related to the functioning of distance relays line protection. Using a consequent simulation model of the EPS (European interconnection) under specified fault condition, the research of EPS operation (relays action) and stability has been done. The appropriate simulation results have been compared to the available measured data which had been collected by the SOREL on-line data acquisition system. In the end, a practise proposal for measures to be taken with the target of achieving the foreseen and expected operation of the EPS equipment that effects operation of the Krsko NPP is given. (author)

  5. The safety of CRT with high-dose cisplatin for head and neck cancers in a community hospital and the renal protection effect with magnesium

    International Nuclear Information System (INIS)

    Ariizumi, Yosuke; Takahashi, Ryosuke; Tateishi, Yumiko; Yamada, Masato

    2016-01-01

    To confirm the safety of CRT with cisplatin 100mg/m"2 for head and neck cancers in a community hospital in Japan and the renal protection effect with magnesium (Mg) supplementation. A retrospective review of 13 head and neck cancers (oropharynx, hypopharynx, and larynx) was conducted. The patients of the 80mgMg - group received CDDP 80mg/m"2 without Mg supplementation, and 100mgMg + group received CDDP 100mg/m"2 with Mg supplementation. Our hospital is a community hospital, therefore second and third administrations of CDDP are discontinued with a lower level of adverse effects than clinical trials. The total dose of CDDP and adverse effects of the two groups were compared. The grade 3 adverse effects were 5 (38%) with stomatitis, 3 (23%) with decreased white blood cell count, 1 (8%) with decreased platelet count, and 1 (8%) with febrile neutropenia. There was no grade 4 adverse effect. The proportion of patients who could receive 200mg/m"2 or more was higher (p = 0.0097) in the 100mgMg + group (7/7) than the 80mgMg - group (1/6). CRT with CDDP 100mg/m"2 at a community hospital in Japan is feasible, with reduction of renal toxicity by Mg supplementation. (author)

  6. Isopropyl Myristate-Modified Polyether-Urethane Coatings as Protective Barriers for Implantable Medical Devices

    Science.gov (United States)

    Roohpour, Nima; Wasikiewicz, Jaroslaw M.; Moshaverinia, Alireza; Paul, Deepen; Rehman, Ihtesham U.; Vadgama, Pankaj

    2009-01-01

    Polyurethane films have potential applications in medicine, especially for packaging implantable medical devices. Although polyether-urethanes have superior mechanical properties and are biocompatible, achieving water resistance is still a challenge. Polyether based polyurethanes with two different molecular weights (PTMO1000, PTMO2000) were prepared from 4,4’-diphenylmethane diisocyanate and poly(tetra-methylene oxide). Polymer films were introduced using different concentrations (0.5-10 wt %) of isopropyl myristate lipid (IPM) as a non-toxic modifying agent. The physical and mechanical properties of these polymers were characterised using physical and spectroscopy techniques (FTIR, Raman, DSC, DMA, tensile testing). Water contact angle and water uptake of the membranes as a function of IPM concentration was also determined accordingly. The FTIR and Raman data indicate that IPM is dispersed in polyurethane at ≤ 2wt% and thermal analysis confirmed this miscibility to be dependent on soft segment length. Modified polymers showed increased tensile strength and failure strain as well as reduced water uptake by up to 24% at 1-2 wt% IPM.

  7. Isopropyl Myristate-Modified Polyether-Urethane Coatings as Protective Barriers for Implantable Medical Devices

    Directory of Open Access Journals (Sweden)

    Pankaj Vadgama

    2009-06-01

    Full Text Available Polyurethane films have potential applications in medicine, especially for packaging implantable medical devices. Although polyether-urethanes have superior mechanical properties and are biocompatible, achieving water resistance is still a challenge. Polyether based polyurethanes with two different molecular weights (PTMO1000, PTMO2000 were prepared from 4,4’-diphenylmethane diisocyanate and poly(tetra-methylene oxide. Polymer films were introduced using different concentrations (0.5-10 wt % of isopropyl myristate lipid (IPM as a non-toxic modifying agent. The physical and mechanical properties of these polymers were characterised using physical and spectroscopy techniques (FTIR, Raman, DSC, DMA, tensile testing. Water contact angle and water uptake of the membranes as a function of IPM concentration was also determined accordingly. The FTIR and Raman data indicate that IPM is dispersed in polyurethane at ≤ 2wt% and thermal analysis confirmed this miscibility to be dependent on soft segment length. Modified polymers showed increased tensile strength and failure strain as well as reduced water uptake by up to 24% at 1-2 wt% IPM.

  8. Evaluation of the Survivability of Microorganisms Deposited on Filtering Respiratory Protective Devices under Varying Conditions of Humidity

    Directory of Open Access Journals (Sweden)

    Katarzyna Majchrzycka

    2016-01-01

    Full Text Available Bioaerosols are common biological factors in work environments, which require routine use of filtering respiratory protective devices (FRPDs. Currently, no studies link humidity changes in the filter materials of such devices, during use, with microorganism survivability. Our aim was to determine the microclimate inside FRPDs, by simulating breathing, and to evaluate microorganism survivability under varying humidity conditions. Breathing was simulated using commercial filtering facepiece respirators in a model system. Polypropylene melt-blown nonwoven fabrics with moisture contents of 40%, 80%, and 200%, were used for assessment of microorganisms survivability. A modified AATCC 100-2004 method was used to measure the survivability of ATCC and NCAIM microorganisms: Escherichia coli, Staphylococcus aureus, Bacillus subtilis, Candida albicans and Aspergillus niger. During simulation relative humidity under the facepiece increased after 7 min of usage to 84%–92% and temperature increased to 29–30 °C. S. aureus survived the best on filter materials with 40%–200% moisture content. A decrease in survivability was observed for E. coli and C. albicans when mass humidity decreased. We found that B. subtilis and A. niger proliferated for 48–72 h of incubation and then died regardless of the moisture content. In conclusion, our tests showed that the survivability of microorganisms on filter materials depends on the amount of accumulated moisture and microorganism type.

  9. Evaluation of the Survivability of Microorganisms Deposited on Filtering Respiratory Protective Devices under Varying Conditions of Humidity.

    Science.gov (United States)

    Majchrzycka, Katarzyna; Okrasa, Małgorzata; Skóra, Justyna; Gutarowska, Beata

    2016-01-04

    Bioaerosols are common biological factors in work environments, which require routine use of filtering respiratory protective devices (FRPDs). Currently, no studies link humidity changes in the filter materials of such devices, during use, with microorganism survivability. Our aim was to determine the microclimate inside FRPDs, by simulating breathing, and to evaluate microorganism survivability under varying humidity conditions. Breathing was simulated using commercial filtering facepiece respirators in a model system. Polypropylene melt-blown nonwoven fabrics with moisture contents of 40%, 80%, and 200%, were used for assessment of microorganisms survivability. A modified AATCC 100-2004 method was used to measure the survivability of ATCC and NCAIM microorganisms: Escherichia coli, Staphylococcus aureus, Bacillus subtilis, Candida albicans and Aspergillus niger. During simulation relative humidity under the facepiece increased after 7 min of usage to 84%-92% and temperature increased to 29-30 °C. S. aureus survived the best on filter materials with 40%-200% moisture content. A decrease in survivability was observed for E. coli and C. albicans when mass humidity decreased. We found that B. subtilis and A. niger proliferated for 48-72 h of incubation and then died regardless of the moisture content. In conclusion, our tests showed that the survivability of microorganisms on filter materials depends on the amount of accumulated moisture and microorganism type.

  10. Radiation beans characterization and implantation for study of lead equivalent individual protection device used in radiodiagnostic practices

    International Nuclear Information System (INIS)

    Pereira, Leslie Silva

    2004-01-01

    The protective shielding (IPC) must be used by occupationally exposed professionals, patients and volunteers, in order to optimize the doses who receive due to radiological practices. International and national norms establish the methodology to be adopted for determination of the IPC attenuation. In this work, the IPC had been submitted to X-rays beams with known characteristics, standardized for determination of their attenuation equivalent thickness by comparison to an experimental lead attenuation slope. This comparison technique allowed insurance estimative of the IPC attenuation equivalent thickness in mm of lead. Thus, it was possible to verify the conformity of the attenuation equivalent thickness determined experimentally and the value of the thickness indicated by the manufacturer. To carry out this work, it was necessary the implementation of experimental setups stated in the specifics norms, the study of the X-rays beams original features and the determination of combined additional filters, in order to allow the X-ray equipment used operates in compliance with Norm IEC 61331-1 IEC. The radiation quality selected is characterized by a 100 kV voltage and a 0.25 mm of copper overall filtration. The implementation of this radiation quality it was carried through of its first and second HVL (Half Value Layer). Thus, a methodology according to the international Norms has been implemented in the laboratory. The results of the present work provide suitable and useful information about radiation beams features related to the determination techniques of the attenuation properties. Once implemented the procedures for conformity evaluation of the protection devices, it will be possible to carry out specific quality control tests, which will be helpful to manufacturers, customers, as well as authorities in the radiological protection and health areas. (author)

  11. Safety and effectiveness of the INVATEC MO.MA proximal cerebral protection device during carotid artery stenting: results from the ARMOUR pivotal trial.

    Science.gov (United States)

    Ansel, Gary M; Hopkins, L Nelson; Jaff, Michael R; Rubino, Paolo; Bacharach, J Michael; Scheinert, Dierk; Myla, Subbarao; Das, Tony; Cremonesi, Alberto

    2010-07-01

    The multicenter ARMOUR (ProximAl PRotection with the MO.MA Device DUring CaRotid Stenting) trial evaluated the 30-day safety and effectiveness of the MO.MA Proximal Cerebral Protection Device (Invatec, Roncadelle, Italy) utilized to treat high surgical risk patients undergoing carotid artery stenting (CAS). Distal embolic protection devices (EPD) have been traditionally utilized during CAS. The MO.MA device acts as a balloon occlusion "endovascular clamping" system to achieve cerebral protection prior to crossing the carotid stenosis. This prospective registry enrolled 262 subjects, 37 roll-in and 225 pivotal subjects evaluated with intention to treat (ITT) from September 2007 to February 2009. Subjects underwent CAS using the MO.MA device. The primary endpoint, myocardial infarction, stroke, or death through 30 days (30-day major adverse cardiac and cerebrovascular events [MACCE]) was compared to a performance goal of 13% derived from trials utilizing distal EPD. For the ITT population, the mean age was 74.7 years with 66.7% of the cohort being male. Symptomatic patients comprised 15.1% and 28.9% were octogenarians. Device success was 98.2% and procedural success was 93.2%. The 30-day MACCE rate was 2.7% [95% CI (1.0-5.8%)] with a 30-day major stroke rate of 0.9%. No symptomatic patient suffered a stroke during this trial. The ARMOUR trial demonstrated that the MO.MA(R) Proximal Cerebral Protection Device is safe and effective for high surgical risk patients undergoing CAS. The absence of stroke in symptomatic patients is the lowest rate reported in any independently adjudicated prospective multicenter registry trial to date. (c) 2010 Wiley-Liss, Inc.

  12. Cerebral ischemic lesions detected with diffusion-weighted magnetic resonance imaging after carotid artery stenting. Comparison of several anti-embolic protection devices

    International Nuclear Information System (INIS)

    Taha, M.M.; Maeda, Masayuki; Sakaida, Hiroshi

    2009-01-01

    Distal embolism is an important periprocedural technical complication with carotid angioplasty and carotid artery stenting (CAS). We evaluated the safety and efficacy of protection devices used during CAS by detecting new cerebral ischemic lesions using diffusion-weighted magnetic resonance imaging in 95 patients who underwent 98 CAS procedures: 34 using single PercuSurge GuardWire, 31 using double balloon protection, 15 using proximal flow reverse protection devices, 14 using Naviballoon, and 4 using filter anti-embolic devices. Diffusion-weighted imaging was performed preoperatively and postoperatively to evaluate the presence of any new embolic cerebral lesions. Postoperative diffusion-weighted imaging revealed 117 new ischemic lesions. Three patients had new ischemic stroke, two minor and one major, all ipsilateral to the treated carotid artery. The remaining patients had clinically silent ischemia. The incidence of new embolic lesions was lower using the proximal flow reverse protection device than with the double balloon protection (33% vs. 48.4%), but the volume of ipsilateral new ischemic lesions per patient was 136.6 mm 3 vs. 86.9 mm 3 , respectively. Neuroprotection with Naviballoon yielded ipsilateral lesions of large volume (86.6 mm 3 ) and higher number (5.7 lesions per patient) than using the filter anti-embolic device (34.8 mm 3 and 1 lesion per patient). New cerebral ischemic lesions after neuroprotected CAS are usually silent. The lower incidence of distal ischemia using proximal flow reverse and double balloon protection devices is limited by the larger volume and higher number of ischemic lesions. (author)

  13. Cerebral ischemic lesions detected with diffusion-weighted magnetic resonance imaging after carotid artery stenting: Comparison of several anti-embolic protection devices.

    Science.gov (United States)

    Taha, Mahmoud M; Maeda, Masayuki; Sakaida, Hiroshi; Kawaguchi, Kenji; Toma, Naoki; Yamamoto, Akitaka; Hirose, Tomofumi; Miura, Youichi; Fujimoto, Masashi; Matsushima, Satoshi; Taki, Waro

    2009-09-01

    Distal embolism is an important periprocedural technical complication with carotid angioplasty and carotid artery stenting (CAS). We evaluated the safety and efficacy of protection devices used during CAS by detecting new cerebral ischemic lesions using diffusion-weighted magnetic resonance imaging in 95 patients who underwent 98 CAS procedures: 34 using single PercuSurge GuardWire, 31 using double balloon protection, 15 using proximal flow reverse protection devices, 14 using Naviballoon, and 4 using filter anti-embolic devices. Diffusion-weighted imaging was performed preoperatively and postoperatively to evaluate the presence of any new embolic cerebral lesions. Postoperative diffusion-weighted imaging revealed 117 new ischemic lesions. Three patients had new ischemic stroke, two minor and one major, all ipsilateral to the treated carotid artery. The remaining patients had clinically silent ischemia. The incidence of new embolic lesions was lower using the proximal flow reverse protection device than with the double balloon protection (33% vs. 48.4%), but the volume of ipsilateral new ischemic lesions per patient was 136.6 mm(3) vs. 86.9 mm(3), respectively. Neuroprotection with Naviballoon yielded ipsilateral lesions of large volume (86.6 mm(3)) and higher number (5.7 lesions per patient) than using the filter anti-embolic device (34.8 mm(3) and 1 lesion per patient). New cerebral ischemic lesions after neuroprotected CAS are usually silent. The lower incidence of distal ischemia using proximal flow reverse and double balloon protection devices is limited by the larger volume and higher number of ischemic lesions.

  14. Process and device for the ultrasonic testing of slotted screws screwed into a head of a nuclear reactor fuel element for cracks

    International Nuclear Information System (INIS)

    Scharpenberg, R.

    1986-01-01

    To achieve correct echo signals, a test head is set separately on each area limited by a slot of the top of the slotted screw and the screw head is ultrasonically sounded in the direction of the suspected cracks. (orig./HP) [de

  15. Proposal for the award of a blanket order contract for the supply of microprocessor-based protection and control devices for the CERN HV distribution network

    CERN Document Server

    2004-01-01

    This document concerns the award of a blanket contract for the supply of microprocessor-based protection and control devices for the CERN HV distribution network. The Finance Committee is invited to agree to the negotiation of a blanket order contract with SCHNEIDER ELECTRIC (PT), the lowest technically acceptable bidder after realignment, for the supply of microprocessor-based protection and control devices for the CERN HV distribution network for a total amount of 1 900 000 euros (2 924 128 Swiss francs), subject to revision for inflation after 1 January 2007. The rate of exchange used is that stipulated in the tender

  16. 21 CFR 868.5560 - Gas mask head strap.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Gas mask head strap. 868.5560 Section 868.5560...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5560 Gas mask head strap. (a) Identification. A gas mask head strap is a device used to hold an anesthetic gas mask in position on a patient's...

  17. Study of performance of acoustic fixture for using in noise reduction rate tests of hearing protection devices

    Directory of Open Access Journals (Sweden)

    zam Biabani

    2016-06-01

    Full Text Available Introduction:One of the recommended methods for evaluation effectiveness of hearing protection is use the acoustic fixture accordance with standard ISO 4869-3. The aim of this study was evaluate the acoustic performance of fixture for using in noise reduction rate tests of hearing protection devices in the laboratory. Methods: In this cross-sectional study , noise reduction rates of five common ear muffs used in the Iran industries were investigated based on the ISO 11904 standard, microphone in real ear method, using noise dosimeter (SVANTEK , Model SV102 equipped with microphone SV25 model which can install inside the ear on 30 subjects under laboratory conditions. Also, noise reduction rate of earmuffs was determined using the fixture model AVASINA9402 accordance with standard procedures. Data were analyzed using the software SPSS21. Results: The results showed the real noise reduction rates of the earmuffs on the studied subjects are from 59% to 94% nominal reduction rates. That rates for the ear muffs on the studied fixture are from 64% to 92.The results showed that the noise reduction rates of the ear muffs on subjects compared with and noise reduction rates of the ear muffs on fixture were not statistically significant (p> 0.05. Conclusion: The results showed the accuracy of noise reduction rate of earmuffs using the fixture compared with real subjects is acceptable. Hence, the fixture is good choice for environments where there’s no possibility of acoustic evaluation on real subjects, also for quality control of productions in the earmuff manufacturers.

  18. Modeling Speech Level as a Function of Background Noise Level and Talker-to-Listener Distance for Talkers Wearing Hearing Protection Devices

    Science.gov (United States)

    Bouserhal, Rachel E.; Bockstael, Annelies; MacDonald, Ewen; Falk, Tiago H.; Voix, Jérémie

    2017-01-01

    Purpose: Studying the variations in speech levels with changing background noise level and talker-to-listener distance for talkers wearing hearing protection devices (HPDs) can aid in understanding communication in background noise. Method: Speech was recorded using an intra-aural HPD from 12 different talkers at 5 different distances in 3…

  19. Directive of the Minister of Public Health and Environmental Protection of 14 October 1975, Stcrt. 203 in implementation of Section 28 of the Nuclear Energy Act (Devices) Decree

    International Nuclear Information System (INIS)

    1975-01-01

    This Directive lays down the procedure for applications for licences under the Devices Decree. The competent authority in this respect is the Minister of Public Health and Environmental Protection, formerly the State Secretary for Social Affairs and Public Health. (NEA) [fr

  20. Generation of a head phantom according to the 95. percentile Chinese population data for evaluating the specific absorption rate by wireless communication devices

    International Nuclear Information System (INIS)

    Ma, Yu; Wang, Yuduo; Shao, Qing; Wu, Tongning; Li, Congsheng

    2014-01-01

    A Chinese head phantom (CHP) is constructed for evaluating the specific absorption rate (SAR) by the wireless transceivers. The dimensions of the head phantom are within 4 % difference compared with the 95. percentile data from the China's standard. The shell's thickness and the configuration of the pinna are the same as those of the specific anthropomorphic mannequin (SAM). Three computable models for the mobile phones are generated and used in the SAR simulations with the SAM and the CHP. The results show that the simulated SAR from the SAM head is similar. Its morphological reason has been analysed. The authors discuss the conservativeness of the two head phantoms as well. The CHP can be used in the inter-laboratory evaluation for the SAR uncertainty. It can also provide the information for the SAR variability due to physical difference, which will benefit the maintenance and the harmonisation of the standards. (authors)

  1. Combined application of distal and proximal embolic protection devices in endovascular stenting for severe carotid artery stenosis

    Directory of Open Access Journals (Sweden)

    Zhi-hua DU

    2011-09-01

    Full Text Available Objective To analyze and summarize methods and experiences of combined application of distal and proximal embolic protection devices(EPD in endovascular stenting for severe carotid artery stenosis.Methods Five patients with severe stenosis of the common carotid artery or with extracranial segment of the internal carotid artery diagnosed through digital subtraction angiography(DSA from March to July 2010 were involved in the present study.All patients received carotid angioplasty and stenting(CAS,with a combination of distal and proximal EPD via the percutaneous femoral artery approach.Results The operation failed in one patient,whereas technical success with no intraoperative complication was achieved in four patients.The symptoms disappeared or improved in the four cases that achieved technical success.The follow-up duration was one to three months,and no cerebral ischemia was found.Conclusion CAS with the combined application of distal and proximal EPD in some special cases of carotid artery stenosis may surmount the shortage of single EPD,reduce the risk of intraoperative embolization,decrease the time of intraoperative endovascular inflow occlusion,and reduce high-risk operations.CAS may be used as an individualized treatment strategy for patients with carotid artery stenosis.

  2. Effects of low speed wind on the recognition/identification and pass-through communication tasks of auditory situation awareness afforded by military hearing protection/enhancement devices and tactical communication and protective systems.

    Science.gov (United States)

    Lee, Kichol; Casali, John G

    2016-01-01

    To investigate the effect of controlled low-speed wind-noise on the auditory situation awareness performance afforded by military hearing protection/enhancement devices (HPED) and tactical communication and protective systems (TCAPS). Recognition/identification and pass-through communications tasks were separately conducted under three wind conditions (0, 5, and 10 mph). Subjects wore two in-ear-type TCAPS, one earmuff-type TCAPS, a Combat Arms Earplug in its 'open' or pass-through setting, and an EB-15LE electronic earplug. Devices with electronic gain systems were tested under two gain settings: 'unity' and 'max'. Testing without any device (open ear) was conducted as a control. Ten subjects were recruited from the student population at Virginia Tech. Audiometric requirements were 25 dBHL or better at 500, 1000, 2000, 4000, and 8000 Hz in both ears. Performance on the interaction of communication task-by-device was significantly different only in 0 mph wind speed. The between-device performance differences varied with azimuthal speaker locations. It is evident from this study that stable (non-gusting) wind speeds up to 10 mph did not significantly degrade recognition/identification task performance and pass-through communication performance of the group of HPEDs and TCAPS tested. However, the various devices performed differently as the test sound signal speaker location was varied and it appears that physical as well as electronic features may have contributed to this directional result.

  3. Cerebral ischemia after filter-protected carotid artery stenting is common and cannot be predicted by the presence of substantial amount of debris captured by the filter device.

    Science.gov (United States)

    Maleux, G; Demaerel, P; Verbeken, E; Daenens, K; Heye, S; Van Sonhoven, F; Nevelsteen, A; Wilms, G

    2006-10-01

    Protected carotid artery stent placement is currently under clinical evaluation as a potential alternative to carotid endarterectomy. The current study was undertaken to determine the incidence of new ischemic lesions found on diffusion-weighted MR imaging (DWI) in nonselected patients after protected carotid artery stent placement using a filter device and to determine the potential relationship between these new ischemic lesions and the presence or absence of a clear amount of debris captured by the neuroprotection filter device. A nonrandomized cohort of 52 patients (40 men, 12 women) presenting with carotid occlusive disease underwent protected carotid artery stent placement using a filter device. DWI obtained 1 day before stent placement was compared with that obtained 1 day after stent placement. In addition, the macroscopic and microscopic analysis of debris captured by the filter device during the carotid stent placement procedure was assessed. Neuroprotected carotid stent placement was technically successful in all 53 procedures but was complicated by a transient ischemic attack in 3 patients (5.6%). In 22 patients (41.5%), new ischemic lesions were found on DWI, and in 21 filter devices (39.6%), a substantial amount of atheromatous plaque and/or fibrin was found. No clear relationship between the presence of debris captured by the filter device and new lesions detected by DWI was found (P = .087; odds ratio 3.067). Neuroprotected carotid artery stent placement will not avoid silent cerebral ischemia. Systematic microscopic analysis of debris captured by the filter device has no predictive value for potential cerebral ischemia after carotid artery stent placement.

  4. Exposure to hazardous workplace noise and use of hearing protection devices among US workers--NHANES, 1999-2004.

    Science.gov (United States)

    Tak, Sangwoo; Davis, Rickie R; Calvert, Geoffrey M

    2009-05-01

    To estimate the prevalence of workplace noise exposure and use of hearing protection devices (HPDs) at noisy work, NIOSH analyzed 1999-2004 data from the National Health and Nutrition Examination Survey (NHANES). A total of 9,275 currently employed workers aged > or =16 years were included in the weighted analysis. Hazardous workplace noise exposure was defined as self-reported exposure to noise at their current job that was so loud that the respondent had to speak in a raised voice to be heard. Industry and occupation were determined based on the respondent's current place and type of work. Twenty-two million US workers (17%) reported exposure to hazardous workplace noise. The weighted prevalence of workplace noise exposure was highest for mining (76%, SE = 7.0) followed by lumber/wood product manufacturing (55%, SE = 2.5). High-risk occupations included repair and maintenance, motor vehicle operators, and construction trades. Overall, 34% of the estimated 22 million US workers reporting hazardous workplace exposure reported non-use of HPDs. The proportion of noise-exposed workers who reported non-use of HPDs was highest for healthcare and social services (73.7%, SE = 8.1), followed by educational services (55.5%). Hearing loss prevention and intervention programs should be targeted at those industries and occupations identified to have a high prevalence of workplace noise exposure and those industries with the highest proportion of noise-exposed workers who reported non-use of HPDs. Published 2009 Wiley-Liss, Inc.

  5. Exclusion of Atherosclerotic Plaque from the Circulation Using Stent-Grafts: Alternative to Carotid Stenting with a Protection Device?

    International Nuclear Information System (INIS)

    Peynircioglu, Bora; Geyik, Serdar; Yavuz, Kivilcim; Cil, Barbaros E.; Saatci, Isil; Cekirge, Saruhan

    2007-01-01

    Purpose. To retrospectively assess the feasibility, safety, and clinical mid-term outcome of patients undergoing carotid artery stenting with stent-grafts. Methods. Over a 4 year period stent-grafts were used in the endovascular treatment of symptomatic internal carotid artery stenosis in 12 patients (2 women, 10 men, aged 47-83 (mean 64) years). Protection devices were not used. Possible microembolic complications were evaluated by magnetic resonance imaging (MRI) examinations of the brain before and the day after the procedure in all patients. Mean follow-up was 22 months (range 1-42 months), by Doppler ultrasonography and conventional angiography as well as clinical examination .Results. The technical success rate was 100%. A total of 13 coronary stent-grafts were used. The mean stenosis rate (in terms of diameter) was 85% and the mean length of stent-grafts used was 20.9 mm. The mean diameter to which the stent-grafts were dilated was 4.66 mm. In-hospital complications occurred in 1 patient who suffered a minor femoral access hematoma that did not require transfusion or surgical decompression. Post-stenting diffusion-weighted MRI revealed several ipsilateral silent microemboli in only 1 case, which was completely asymptomatic. Two patients had a major stroke after 2 years of follow-up. Restenosis was found in 2 patients who underwent successful balloon dilatation followed by placement of a self-expandable bare stent within the stent-grafts. Conclusions. Stent-grafts may prevent microembolic complications during stenting of atherosclerotic carotid lesions in selected cases, offering immediate exclusion of the atherosclerotic lesion from the circulation by pressing the plaque against the vessel wall. Comparative, randomized studies in larger series of patients are needed with carotid-dedicated stent-graft designs

  6. A framework for geometry acquisition, 3-D printing, simulation, and measurement of head-related transfer functions with a focus on hearing-assistive devices

    DEFF Research Database (Denmark)

    Harder, Stine; Paulsen, Rasmus Reinhold; Larsen, Martin

    2016-01-01

    of a three-dimensional (3D) head model for acquisition of individual HRTFs. Two aspects were investigated; whether a 3D-printed model can replace measurements on a human listener and whether numerical simulations can replace acoustic measurements. For this purpose, HRTFs were acoustically measured for four...... human listeners and for a 3D printed head model of one of these listeners. Further, HRTFs were simulated by applying the finite element method to the 3D head model. The monaural spectral features and spectral distortions were very similar between re-measurements and between human and printed...... measurements, however larger deviations were observed between measurement and simulation. The binaural cues were in agreement among all HRTFs of the same listener, indicating that the 3D model is able to provide localization cues potentially accessible to HAD users. Hence, the pipeline of geometry acquisition...

  7. 21 CFR 892.1920 - Radiographic head holder.

    Science.gov (United States)

    2010-04-01

    ...) Identification. A radiographic head holder is a device intended to position the patient's head during a... device is also exempt from the current good manufacturing practice requirements of the quality system...

  8. Cerebral Ischemia Detected with Diffusion-Weighted MR Imaging after Protected Carotid Artery Stenting: Comparison of Distal Balloon and Filter Device

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Suk Jung; Jeon, Pyoung [Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); Roh, Hong Gee [Konkuk University Hospital, Seoul (Korea, Republic of)] (and others)

    2007-08-15

    The aim of this study was to examine the incidence of ischemia during protected carotid artery stenting (CAS) as well as to compare the protective efficacy of the balloon and filter devices on diffusion-weighted MR imaging (DWI). Seventy-one consecutive protected CAS procedures in 70 patients with a severe (> 70%) or symptomatic moderate (> 50%) carotid artery stenosis were examined. A balloon device (PercuSurge GuardWire) and a filter device (FilterWire EX/EZ, Emboshield) was used in 33 cases (CAS-B group) and 38 cases (CAS-F group) to prevent distal embolization, respectively. All the patients underwent DWI within seven days before and after the procedures. The number of new cerebral ischemic lesions on the post-procedural DWI were counted and divided into ipsilateral and contralateral lesions according to the relationship with the stenting side. New cerebral ischemic lesions were detected in 13 (39.4%) out of the 33 CAS-Bs and in 15 (39.5%) out of the 38 CAS-Fs. The mean number of total, ipsilateral and contralateral new cerebral ischemic lesion was 2.39, 1.67 and 0.73 in the CAS-B group and 2.11, 1.32 and 0.79 in the CAS-F group, respectively. No statistical differences were found between the two groups (p = 0.96, 0.74 and 0.65, respectively). The embolic complications encountered included two retinal infarctions and one hemiparesis in the CAS-B group (9.09%), and one retinal infarction, one hemiparesis and one ataxia in the CAS-F group (7.89%). There was a similar incidence of embolic complications in the two groups (p 1.00). The type of distal protection device used such as a balloon and filter does not affect the incidence of cerebral embolization after protected CAS.

  9. Portable hyperspectral device as a valuable tool for the detection of protective agents applied on hystorical buildings

    Science.gov (United States)

    Vettori, S.; Pecchioni, E.; Camaiti, M.; Garfagnoli, F.; Benvenuti, M.; Costagliola, P.; Moretti, S.

    2012-04-01

    In the recent past, a wide range of protective products (in most cases, synthetic polymers) have been applied to the surfaces of ancient buildings/artefacts to preserve them from alteration [1]. The lack of a detailed mapping of the permanence and efficacy of these treatments, in particular when applied on large surfaces such as building facades, may be particularly noxious when new restoration treatments are needed and the best choice of restoration protocols has to be taken. The presence of protective compounds on stone surfaces may be detected in laboratory by relatively simple diagnostic tests, which, however, normally require invasive (or micro-invasive) sampling methodologies and are time-consuming, thus limiting their use only to a restricted number of samples and sampling sites. On the contrary, hyperspectral sensors are rapid, non-invasive and non-destructive tools capable of analyzing different materials on the basis of their different patterns of absorption at specific wavelengths, and so particularly suitable for the field of cultural heritage [2,3]. In addition, they can be successfully used to discriminate between inorganic (i.e. rocks and minerals) and organic compounds, as well as to acquire, in short times, many spectra and compositional maps at relatively low costs. In this study we analyzed a number of stone samples (Carrara Marble and biogenic calcarenites - "Lecce Stone" and "Maastricht Stone"-) after treatment of their surfaces with synthetic polymers (synthetic wax, acrylic, perfluorinated and silicon based polymers) of common use in conservation-restoration practice. The hyperspectral device used for this purpose was ASD FieldSpec FR Pro spectroradiometer, a portable, high-resolution instrument designed to acquire Visible and Near-Infrared (VNIR: 350-1000 nm) and Short-Wave Infrared (SWIR: 1000-2500 nm) punctual reflectance spectra with a rapid data collection time (about 0.1 s for each spectrum). The reflectance spectra so far obtained in

  10. Nuclear fast neutron reactor cooled by a liquid metal and of which internal structures are equipped with a thermal protection device

    International Nuclear Information System (INIS)

    Lemercier, G.; Lions, N.

    1986-01-01

    The internal structures of a nuclear fast neutron reactor are covered at least partially, on the most hot side, by a thermal protection device. This device comprises modular plates arranged end to end with a certain play between themselves and taking approximately the shape of the internal structures. Each plate is fixed in its center on the internal structures by a stud. A small plate fixed at one of the corners of each plate and covering partially the adjacent plates ensures the safety fixing of these ones [fr

  11. Professional installation of overvoltage protection devices. The most common installation errors; Fachgerechte Installation von Ueberspannungsschutzgeraeten. Die haeufigsten Installationsfehler

    Energy Technology Data Exchange (ETDEWEB)

    Gmelch, L. [Dehn und Soehne GmbH und Co. KG, Neumarkt (Germany)

    2007-07-01

    Increasingly sensitive electronic equipment and high demands on plant and system availability necesstate effective protection against lightning and overvoltage. Apart from the measures that must be taken already in the projecting phase in order to minimize the risk of interferences, disturbances and destruction of plants and systems, there are also some basic principles that must be observed when installing overvoltage protection equipment. If these are neglected, the protective function of overvoltage protection systems may be seriously impaired. (orig.)

  12. Development of the self-learning machine for creating models of microprocessor of single-phase earth fault protection devices in networks with isolated neutral voltage above 1000 V

    Science.gov (United States)

    Utegulov, B. B.; Utegulov, A. B.; Meiramova, S.

    2018-02-01

    The paper proposes the development of a self-learning machine for creating models of microprocessor-based single-phase ground fault protection devices in networks with an isolated neutral voltage higher than 1000 V. Development of a self-learning machine for creating models of microprocessor-based single-phase earth fault protection devices in networks with an isolated neutral voltage higher than 1000 V. allows to effectively implement mathematical models of automatic change of protection settings. Single-phase earth fault protection devices.

  13. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... it may cause some medical devices to malfunction. Most orthopedic implants pose no risk, but you should ... a digital cloud server. Currently, MRI is the most sensitive imaging test of the head (particularly the ...

  14. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... is not harmful, but it may cause some medical devices to malfunction. Most orthopedic implants pose no ... Head? Magnetic resonance imaging (MRI) is a noninvasive medical test that physicians use to diagnose medical conditions. ...

  15. Protective

    Directory of Open Access Journals (Sweden)

    Wessam M. Abdel-Wahab

    2013-10-01

    Full Text Available Many active ingredients extracted from herbal and medicinal plants are extensively studied for their beneficial effects. Antioxidant activity and free radical scavenging properties of thymoquinone (TQ have been reported. The present study evaluated the possible protective effects of TQ against the toxicity and oxidative stress of sodium fluoride (NaF in the liver of rats. Rats were divided into four groups, the first group served as the control group and was administered distilled water whereas the NaF group received NaF orally at a dose of 10 mg/kg for 4 weeks, TQ group was administered TQ orally at a dose of 10 mg/kg for 5 weeks, and the NaF-TQ group was first given TQ for 1 week and was secondly administered 10 mg/kg/day NaF in association with 10 mg/kg TQ for 4 weeks. Rats intoxicated with NaF showed a significant increase in lipid peroxidation whereas the level of reduced glutathione (GSH and the activity of superoxide dismutase (SOD, catalase (CAT, glutathione S-transferase (GST and glutathione peroxidase (GPx were reduced in hepatic tissues. The proper functioning of the liver was also disrupted as indicated by alterations in the measured liver function indices and biochemical parameters. TQ supplementation counteracted the NaF-induced hepatotoxicity probably due to its strong antioxidant activity. In conclusion, the results obtained clearly indicated the role of oxidative stress in the induction of NaF toxicity and suggested hepatoprotective effects of TQ against the toxicity of fluoride compounds.

  16. Influence of stent design and use of protection devices on outcome of carotid artery stenting: a pooled analysis of individual patient data.

    Science.gov (United States)

    Wodarg, Fritz; Turner, Elisabeth L; Dobson, Joanna; Ringleb, Peter A; Mali, Willem P; Fraedrich, Gustav; Chatellier, Gilles; Bequemin, Jean-Pierre; Brown, Martin M; Algra, Ale; Mas, Jean-Louis; Jansen, Olav; Bonati, Leo H

    2018-04-19

    Carotid artery stenting is an alternative to endarterectomy for the treatment of symptomatic carotid stenosis but was associated with a higher risk of procedural stroke or death in randomized controlled trials (RCTs). Technical aspects of treatment may partly explain these results. The purpose of this analysis was to investigate the influence of technical aspects such as stent design or the use of protection devices, as well as clinical variables, on procedural risk. We pooled data of 1557 individual patients receiving stent treatment in three large RCTs comparing stenting versus endarterectomy for symptomatic carotid stenosis. The primary outcome event was any procedural stroke or death occurring within 30 days after stenting. Procedural stroke or death occurred significantly more often with the use of open-cell stents (61/595 patients, 10.3%) than with closed-cell stents (58/962 patients, 6.0%; RR 1.76; 95% CI 1.23 to 2.52; P=0.002). Procedural stroke or death occurred in 76/950 patients (8.0%) treated with protection devices (predominantly distal filters) and in 43/607 (7.1%) treated without protection devices (RR 1.10; 95% CI 0.71 to 1.70; P=0.67). Clinical variables predicting the primary outcome event were age, severity of the qualifying event, history of prior stroke, and level of disability at baseline. The effect of stent design remained similar after adjustment for these variables. In symptomatic carotid stenosis, the use of stents with a closed-cell design is independently associated with a lower risk of procedural stroke or death compared with open-cell stents. Filter-type protection devices do not appear to reduce procedural risk. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  17. Pancreatic Tissue Transplanted in TheraCyte Encapsulation Devices Is Protected and Prevents Hyperglycemia in a Mouse Model of Immune-Mediated Diabetes.

    Science.gov (United States)

    Boettler, Tobias; Schneider, Darius; Cheng, Yang; Kadoya, Kuniko; Brandon, Eugene P; Martinson, Laura; von Herrath, Matthias

    2016-01-01

    Type 1 diabetes (T1D) is characterized by destruction of glucose-responsive insulin-producing pancreatic β-cells and exhibits immune infiltration of pancreatic islets, where CD8 lymphocytes are most prominent. Curative transplantation of pancreatic islets is seriously hampered by the persistence of autoreactive immune cells that require high doses of immunosuppressive drugs. An elegant approach to confer graft protection while obviating the need for immunosuppression is the use of encapsulation devices that allow for the transfer of oxygen and nutrients, yet prevent immune cells from making direct contact with the islet grafts. Here we demonstrate that macroencapsulation devices (TheraCyte) loaded with neonatal pancreatic tissue and transplanted into RIP-LCMV.GP mice prevented disease onset in a model of virus-induced diabetes mellitus. Histological analyses revealed that insulin-producing cells survived within the device in animal models of diabetes. Our results demonstrate that these encapsulation devices can protect from an immune-mediated attack and can contain a sufficient amount of insulin-producing cells to prevent overt hyperglycemia.

  18. Use of a holder-vacuum tube device to save on-site hands in preparing urine samples for head-space gas-chromatography, and its application to determine the time allowance for sample sealing.

    Science.gov (United States)

    Kawai, Toshio; Sumino, Kimiaki; Ohashi, Fumiko; Ikeda, Masayuki

    2011-01-01

    To facilitate urine sample preparation prior to head-space gas-chromatographic (HS-GC) analysis. Urine samples containing one of the five solvents (acetone, methanol, methyl ethyl ketone, methyl isobutyl ketone and toluene) at the levels of biological exposure limits were aspirated into a vacuum tube via holder, a device commercially available for venous blood collection (the vacuum tube method). The urine sample, 5 ml, was quantitatively transferred to a 20-ml head-space vial prior to HS-GC analysis. The loaded tubes were stored at +4 ℃ in dark for up to 3 d. The vacuum tube method facilitated on-site procedures of urine sample preparation for HS-GC with no significant loss of solvents in the sample and no need of skilled hands, whereas on-site sample preparation time was significantly reduced. Furthermore, no loss of solvents was detected during the 3-d storage, irrespective of hydrophilic (acetone) or lipophilic solvent (toluene). In a pilot application, high performance of the vacuum tube method in sealing a sample in an air-tight space succeeded to confirm that no solvent will be lost when sealing is completed within 5 min after urine voiding, and that the allowance time is as long as 30 min in case of toluene in urine. The use of the holder-vacuum tube device not only saves hands for transfer of the sample to air-tight space, but facilitates sample storage prior to HS-GC analysis.

  19. Radiation protective clothing

    International Nuclear Information System (INIS)

    Watanabe, Choshin; Takaura, Katsutoshi

    1998-01-01

    An external clothing as a main portion of the radiation protective clothing of the present invention is adapted to cover substantially the entire body of a wearer, comprises a moisture permeable material partially or entirely, and has an air supply device equipped with a filter for feeding air to a head portion of the wearer in the external clothing. Cleaned air filtered by the filter is supplied to the head portion of a wearer in the external clothing. The air passes through remarkably perspiratory head, face, shoulder, chest and back portions to remove heat and sweat at sensitively important upper portions of a body, so that humidity is released to remove fatigues and improve workability. In addition, since some extent of internal pressure is exerted to the inside of the external clothing by the air supply, contaminated air does not intrude from the outside to the external clothing. Since the air supply device is attached and carried to the external clothing, there is no air line hose which disturbs operation. (I.S.)

  20. Navigation in head and neck oncological surgery: an emerging concept.

    Science.gov (United States)

    Gangloff, P; Mastronicola, R; Cortese, S; Phulpin, B; Sergeant, C; Guillemin, F; Eluecque, H; Perrot, C; Dolivet, G

    2011-01-01

    Navigation surgery, initially applied in rhinology, neurosurgery and orthopaedic cases, has been developed over the last twenty years. Surgery based on computed tomography data has become increasingly important in the head and neck region. The technique for hardware fusion between RMI and computed tomography is also becoming more useful. We use such device since 2006 in head and neck carcinologic situation. Navigation allows control of the resection in order to avoid and protect the precise anatomical structures (vessels and nerves). It also guides biopsy and radiofrequency. Therefore, quality of life is much more increased and morbidity is decreased for these patients who undergo major and mutilating head and neck surgery. Here we report the results of 33 navigation procedures performed for 31 patients in our institution.

  1. Characterizing the Utility and Limitations of Repurposing an Open-Field Optical Imaging Device for Fluorescence-Guided Surgery in Head and Neck Cancer Patients.

    Science.gov (United States)

    Moore, Lindsay S; Rosenthal, Eben L; Chung, Thomas K; de Boer, Esther; Patel, Neel; Prince, Andrew C; Korb, Melissa L; Walsh, Erika M; Young, E Scott; Stevens, Todd M; Withrow, Kirk P; Morlandt, Anthony B; Richman, Joshua S; Carroll, William R; Zinn, Kurt R; Warram, Jason M

    2017-02-01

    The purpose of this study was to assess the potential of U.S. Food and Drug Administration-cleared devices designed for indocyanine green-based perfusion imaging to identify cancer-specific bioconjugates with overlapping excitation and emission wavelengths. Recent clinical trials have demonstrated potential for fluorescence-guided surgery, but the time and cost of the approval process may impede clinical translation. To expedite this translation, we explored the feasibility of repurposing existing optical imaging devices for fluorescence-guided surgery. Consenting patients (n = 15) scheduled for curative resection were enrolled in a clinical trial evaluating the safety and specificity of cetuximab-IRDye800 (NCT01987375). Open-field fluorescence imaging was performed preoperatively and during the surgical resection. Fluorescence intensity was quantified using integrated instrument software, and the tumor-to-background ratio characterized fluorescence contrast. In the preoperative clinic, the open-field device demonstrated potential to guide preoperative mapping of tumor borders, optimize the day of surgery, and identify occult lesions. Intraoperatively, the device demonstrated robust potential to guide surgical resections, as all peak tumor-to-background ratios were greater than 2 (range, 2.2-14.1). Postresection wound bed fluorescence was significantly less than preresection tumor fluorescence (P open-field imaging device was successfully repurposed to distinguish cancer from normal tissue in the preoperative clinic and throughout surgical resection. This study illuminated the potential for existing open-field optical imaging devices with overlapping excitation and emission spectra to be used for fluorescence-guided surgery. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.

  2. Presentation of a 3D conformal radiotherapy technique for head-and-neck tumors resulting in substantial protection of the parotid glands

    International Nuclear Information System (INIS)

    Kuhnt, T.; Janich, M.; Gerlach, R.; Haensgen, G.; Goetz, U.; Chiricuta, I.C.

    2006-01-01

    Purpose: the aim of this study was to improve the irradiation technique for the treatment of head-and-neck tumors and, in particular, to make use of the advantages found in modern 3D planning to protect the parotid glands. Patients and methods: for this investigation the 3D dataset of a standard patient with oropharyngeal carcinoma of UICC stage IVA was used. In the CT scans (slice thickness 5 mm) the planning target volume (PTV), the boost volume and both parotids were delineated. Three different techniques were calculated for two different dose levels (50 Gy for PTV and 64 Gy for boost volume, using single doses of 2 Gy). For technique 1 (T1) a parallel opposed field photon/electron irradiation was designed, for technique 2 (T2) an opposed/arc field irradiation was employed, and for technique 3 (T3) a combination of a static coplanar and arc field irradiation was designed. The sum doses D min , D max and D mean for PTV, boost volume, and ipsilateral and contralateral parotid gland were evaluated, and the time needed for calculation of the plans was also determined. Results: for all techniques used, the calculated doses in the PTV (D min 5.6 ± 0.1 Gy, D max 73.7 ± 0.1 Gy, and D mean 57.9 ± 0.5 Gy) and in the boost volume (D min 46.9 ± 1.5 Gy, D max 73.8 ± 0.12 Gy, and D mean 65.8 ± 0.9 Gy) were equal. Significant differences were found regarding the three different techniques, e.g., for the ipsilateral parotid gland D min (T1 = 47.4, T2 = 50.6, and T3 = 38.4 Gy) as well as for the contralateral parotid gland D min (T1 = 42.1, T2 = 44.2, and T3 = 17.8 Gy) and D mean (T1 = 51.3, T2 = 52.8, and T3 = 32.6 Gy). Regarding the three different techniques, significant differences were found in favor of T3. The determined planning times were as follows: T1 = 90, T2 = 60, and T3 = 90 min. Conclusion: the combination of static coplanar and arc field technique (T3) resulted in a substantially better protection as compared to both other techniques. This was especially the

  3. Components for containment enclosures. Part 4: Ventilation and gas-cleaning systems such as filters, traps, safety and regulation valves, control and protection devices

    International Nuclear Information System (INIS)

    2001-01-01

    ISO 11933 consists of the following parts, under the general title Components for containment enclosures: Part 1: Glove/bag ports, bungs for glove/bag ports, enclosure rings and interchangeable units; Part 2: Gloves, welded bags, gaiters for remote-handling tongs and for manipulators; Part 3: Transfer systems such as plain doors, airlock chambers, double door transfer systems, leaktight connections for waste drums; Part 4: Ventilation and gas-cleaning systems such as filters, traps, safety and regulation valves, control and protection devices; Part 5: Penetrations for electrical and fluid circuits. This part of ISO 11933 specifies the design criteria and the characteristics of various components used for ventilation and gas-cleaning in containment enclosures. These components are either directly fixed to the containment enclosure wall, or used in the environment of a shielded or unshielded containment enclosure or line of such enclosures. They can be used alone or in conjunction with other mechanical components, including those specified in ISO 11933-1 and ISO 11933-3. This part of ISO 11933 is applicable to: filtering devices, including high-efficiency particulate air (HEPA) filters and iodine traps; safety valves and pressure regulators; systems ensuring the mechanical protection of containment enclosures; control and pressure-measurement devices

  4. Head Lice

    Science.gov (United States)

    ... nits. You should also use hot water to wash any bed linens, towels, and clothing recently worn by the person who had head lice. Vacuum anything that can’t be washed, such as the couch, carpets, your child’s car seat, and any stuffed animals. Because head lice ...

  5. IAEA calls for enhanced radiation protection of patients. Safety specialists warn against overuse of new imaging devices

    International Nuclear Information System (INIS)

    2009-01-01

    Advances in medical imaging techniques are allowing doctors to detect hidden diseases and make ever more accurate diagnoses. But radiation safety experts at the International Atomic Energy Agency (IAEA) say that overuse of high-tech scanning procedures may unnecessarily expose patients to increased radiation levels. The IAEA, in collaboration with other international organizations, is developing a series of measures aimed at strengthening patient protection. The focus of recent efforts is a Smart Card project, to log how much radiation a person receives in the course of a lifetime. Concern surrounds procedures such as computed tomography (CT) scans because they deliver higher doses of radiation to patients in comparison to conventional X-rays (radiographs). It's been estimated that the average radiation dose of one CT scan is equal to roughly 500 chest X-rays. And that can increase a patient's lifetime risk of cancer, particularly if CT scans are repeated. The IAEA is one of the key international players in the field of patient radiation protection. A unit dedicated to the Radiological Protection of Patients (RPoP) was established in 2001. The IAEA's activities in radiation protection of patients include training, knowledge sharing and capacity building in the medical use of radiation. Extensive, up-to-date training material for health professionals is freely available on the RPoP website. An International Action Plan on the Radiological Protection of Patients that has been established together with leading international organizations such as the World Health Organization (WHO), UNSCEAR, the International Commission on Radiological Protection (ICRP) and others to identify strategies for strengthening radiation protection of patients. Coordinating and managing technical cooperation projects with Member States on patient dose assessment. The aim is to identify the factors that contribute to unnecessary radiation dose to patients, provide guidance on dealing with

  6. Anatomic and dosimetric changes in patients with head and neck cancer treated with an integrated MRI-tri-60Co teletherapy device.

    Science.gov (United States)

    Raghavan, Govind; Kishan, Amar U; Cao, Minsong; Chen, Allen M

    2016-11-01

    Prior studies have relied on CT to assess alterations in anatomy among patients undergoing radiation for head and neck cancer. We sought to determine the feasibility of using MRI-based image-guided radiotherapy to quantify these changes and to ascertain their potential dosimetric implications. 6 patients with head and neck cancer were treated with intensity-modulated radiotherapy (IMRT) on a novel tri- 60 Co teletherapy system equipped with a 0.35-T MRI (VR, ViewRay Incorporated, Oakwood Village, OH) to 66-70 Gy in 33 fractions (fx). Pre-treatment MRIs on Fx 1, 5, 10, 15, 20, 25, 30 and 33 were imported into a contouring interface, where the primary gross tumour volume (GTV) and parotid glands were delineated. The centre of mass (COM) shifts for these structures were assessed relative to Day 1. Dosimetric data were co-registered with the MRIs, and doses to the GTV and parotid glands were assessed. Primary GTVs decreased significantly over the course of IMRT (median % volume loss, 38.7%; range, 29.5-72.0%; p < 0.05) at a median rate of 1.2%/fx (range, 0.92-2.2%/fx). Both the ipsilateral and contralateral parotid glands experienced significant volume loss (p < 0.05, for all) and shifted medially during IMRT. Weight loss correlated significantly with parotid gland volume loss and medial COM shift (p < 0.05). Integrated on-board MRI can be used to accurately contour and analyze primary GTVs and parotid glands over the course of IMRT. COM shifts and significant volume reductions were observed, confirming the results of prior CT-based exercises. Advances in knowledge: The superior resolution of on-board MRI may facilitate online adaptive replanning in the future.

  7. Modeling Speech Level as a Function of Background Noise Level and Talker-to-Listener Distance for Talkers Wearing Hearing Protection Devices

    DEFF Research Database (Denmark)

    Bouserhal, Rachel E.; Bockstael, Annelies; MacDonald, Ewen

    2017-01-01

    Purpose: Studying the variations in speech levels with changing background noise level and talker-to-listener distance for talkers wearing hearing protection devices (HPDs) can aid in understanding communication in background noise. Method: Speech was recorded using an intra-aural HPD from 12...... complements the existing model presented by Pelegrín-García, Smits, Brunskog, and Jeong (2011) and expands on it by taking into account the effects of occlusion and background noise level on changes in speech sound level. Conclusions: Three models of the relationship between vocal effort, background noise...

  8. A Novel Technique Using a Protection Filter During Fibrin Sheath Removal for Implanted Venous Access Device Dysfunction

    Energy Technology Data Exchange (ETDEWEB)

    Sotiriadis, Charalampos; Hajdu, Steven David [University Hospital of Lausanne, Cardiothoracic and Vascular Unit, Department of Radiology (Switzerland); Degrauwe, Sophie [University Hospital of Lausanne, Department of Cardiology (Switzerland); Barras, Heloise; Qanadli, Salah Dine, E-mail: salah.qanadli@chuv.ch [University Hospital of Lausanne, Cardiothoracic and Vascular Unit, Department of Radiology (Switzerland)

    2016-08-15

    With the increased use of implanted venous access devices (IVADs) for continuous long-term venous access, several techniques such as percutaneous endovascular fibrin sheath removal, have been described, to maintain catheter function. Most standard techniques do not capture the stripped fibrin sheath, which is subsequently released in the pulmonary circulation and may lead to symptomatic pulmonary embolism. The presented case describes an endovascular technique which includes stripping, capture, and removal of fibrin sheath using a novel filter device. A 64-year-old woman presented with IVAD dysfunction. Stripping was performed using a co-axial snare to the filter to capture the fibrin sheath. The captured fragment was subsequently removed for visual and pathological verification. No immediate complication was observed and the patient was discharged the day of the procedure.

  9. Device for protecting the section of the airline electricity transmission with insulated neutral from incomplete phase modes

    Energy Technology Data Exchange (ETDEWEB)

    Sagutdinov, R.Sh.; Batoyev, D.

    1982-01-01

    The device for USSR certificate of authorship 792439 is improved in order to raise reliability of isolating the damage zone by including into operation an antenna filter for voltage of zero sequence (AFNIP) only during the operating time of the electrical unit in incomplete phase mode. The newly introduced circuit breaker contract of the inlet relay of the voltage filter for reverse sequence is connected between the outlet of the AFNIP and the ground. The device additionally has a time relay which is connected to the outlet of the voltage filter of reverse sequence. The circuit breaker contact of the inlet relay AFNIP is connected in series to the closure contact of the time relay and the winding of the second outlet relay of the actuating mechanism.

  10. Metoda ispitivanja kompatibilnosti sredstava lične NHB zaštite / Method of testing compatibility of personal NBC protection devices

    Directory of Open Access Journals (Sweden)

    Dušan Rajić

    2009-07-01

    Full Text Available Na primeru izabranih sredstava lične NHB zaštite demonstrirana je primena metode procene kompatibilnosti, kao vrlo bitne taktičko-tehničke karakteristike za svako novouvedeno sredstvo naoružanja i vojne opreme (NVO u Vojsci Srbije. Utvrđeno je da zaštitno filtrirajuće odelo, zaštitni laki ogrtač i zaštitne rukavice ispunjavaju postavljene kriterijume kompatibilnosti. Opisana metoda provere kompatibilnosti može da se primenjuje i na druga sredstva NVO u fazama razvoja, proizvodnje i eksploatacije. / The selected personal NBC protection devices have served as an example for demonstrating the application of the compatibility evaluation method as a very important tactical-technical characteristic of each newly introduced item of weapon and military equipment in the Serbian army. It has been determined that a filtering protective suit, a light protective coat and protective gloves meet the required criteria of compatibility. The described method of testing compatibility can be also applied to other weapons and military equipment in stages of development, production and exploitation.

  11. Can Smartphones and Privacy Coexist Assessing Technologies and Regulations Protecting Personal Data on Android and iOS Devices

    Science.gov (United States)

    2016-01-01

    from unknown sources even if they have not been approved for the app store (“Google Report: Android Security 2014 Year in Review,” 2014). This makes...Report: Android Security 2014 Year in Review,” 2014. As of October 2015: https://static.googleusercontent.com/media/source.android.com/ en//devices...Experience Returns for Security (BADGERS), September 11, 2014. Lockheimer, Hiroshi, “ Android and Security ,” Google Mobile Blog, February 2, 2012. As

  12. Head First Mobile Web

    CERN Document Server

    Gardner, Lyza; Grigsby, Jason

    2011-01-01

    Despite the huge number of mobile devices and apps in use today, your business still needs a website. You just need it to be mobile. Head First Mobile Web walks you through the process of making a conventional website work on a variety smartphones and tablets. Put your JavaScript, CSS media query, and HTML5 skills to work-then optimize your site to perform its best in the demanding mobile market. Along the way, you'll discover how to adapt your business strategy to target specific devices. Navigate the increasingly complex mobile landscapeTake both technical and strategic approaches to mobile

  13. Development of a test device to characterize thermal protective performance of fabrics against hot steam and thermal radiation

    International Nuclear Information System (INIS)

    Su, Yun; Li, Jun

    2016-01-01

    Steam burns severely threaten the life of firefighters in the course of their fire-ground activities. The aim of this paper was to characterize thermal protective performance of flame-retardant fabrics exposed to hot steam and low-level thermal radiation. An improved testing apparatus based on ASTM F2731-11 was developed in order to simulate the routine fire-ground conditions by controlling steam pressure, flow rate and temperature of steam box. The thermal protective performance of single-layer and multi-layer fabric system with/without an air gap was studied based on the calibrated tester. It was indicated that the new testing apparatus effectively evaluated thermal properties of fabric in hot steam and thermal radiation. Hot steam significantly exacerbated the skin burn injuries while the condensed water on the skin’s surface contributed to cool down the skin tissues during the cooling. Also, the absorbed thermal energy during the exposure and the cooling was mainly determined by the fabric’s configuration, the air gap size, the exposure time and the existence of hot steam. The research provides a effective method to characterize the thermal protection of fabric in complex conditions, which will help in optimization of thermal protection performance of clothing and reduction of steam burn. (paper)

  14. Electromagnetic Pulse/Transient Threat Testing of Protection Devices for Amateur/Military Affiliate Radio System Equipment. Volume 2

    Science.gov (United States)

    1985-10-31

    4-45 4-1 SPC =. NTiC)NS I SPIKEGUARD SUPPRESSORS NANOSECOND TRANSIENT PROTECTION MODELS AVAILABLE FOR ,u * COAXIAL LINES...molded epoxy casc 4-40 General1- ~ *Sewiconductor4*industries,, Inc. Squats D oE.!v! MAXIMUM RATINGS DESCRIPTION coNro CASE 19 * Steady State POWr I

  15. Head Injuries

    Science.gov (United States)

    ... a severe blow to the head can still knock the brain into the side of the skull ... following certain precautions and taking a break from sports and other activities that make symptoms worse. Playing ...

  16. Revascularization for critical limb ischemia using the SpiderFX embolic protection device in the below-the-knee circulation: initial results.

    Science.gov (United States)

    Ward, Thomas J; Piechowiak, Rachel L; Patel, Rahul S; Fischman, Aaron M; Nowakowski, F Scott; Kim, Edward; Ellozy, Sharif H; Faries, Peter L; Lookstein, Robert A

    2014-10-01

    To examine the safety and efficacy of the SpiderFX embolic protection device (EPD) in the below-the-knee (BTK) circulation in patients with critical limb ischemia (CLI). A single-center retrospective review was performed to identify patients with CLI and single-vessel runoff in whom the SpiderFX EPD was used in the BTK circulation. Technical success and device-related complications were the primary endpoints. Retrieval of macroscopic debris in the EPD, 1-year freedom from major adverse limb events (MALEs), and 30-day perioperative death were also evaluated. A major amputation, surgical bypass, endovascular thrombectomy, or endovascular thrombolysis was considered a MALE. Thirty-six patients (21 men; mean age, 75.8 y) treated between 2008 and 2013 had endovascular revascularization with use of the SpiderFX EPD in the BTK circulation. The SpiderFX EPD was successfully deployed in all cases; the technical success rate of revascularization was 100%. Two minor and zero major complications were observed related to the SpiderFX. Two MALEs, a major amputation and a subsequent surgical bypass, were observed in the cohort. All MALEs occurred within 1 year of treatment (1-y freedom from MALE rate, 90%). Debris was retrieved in the SpiderFX device in 47% of patients. The use of the SpiderFX EPD in the BTK circulation in patients with CLI is safe and frequently retrieves debris. Copyright © 2014 SIR. Published by Elsevier Inc. All rights reserved.

  17. Using Africa's protected area network to estimate the global population of a threatened and declining species: a case study of the Critically Endangered White-headed Vulture Trigonoceps occipitalis.

    Science.gov (United States)

    Murn, Campbell; Mundy, Peter; Virani, Munir Z; Borello, Wendy D; Holloway, Graham J; Thiollay, Jean-Marc

    2016-02-01

    The White-headed Vulture Trigonoceps occipitalis (WhV) is uncommon and largely restricted to protected areas across its range in sub-Saharan Africa. We used the World Database on Protected Areas to identify protected areas (PAs) likely to contain White-headed Vultures. Vulture occurrence on road transects in Southern, East, and West Africa was adjusted to nests per km(2) using data from areas with known numbers of nests and corresponding road transect data. Nest density was used to calculate the number of WhV nests within identified PAs and from there extrapolated to estimate the global population. Across a fragmented range, 400 PAs are estimated to contain 1893 WhV nests. Eastern Africa is estimated to contain 721 nests, Central Africa 548 nests, Southern Africa 468 nests, and West Africa 156 nests. Including immature and nonbreeding birds, and accounting for data deficient PAs, the estimated global population is 5475 - 5493 birds. The identified distribution highlights are alarming: over 78% (n = 313) of identified PAs contain fewer than five nests. A further 17% (n = 68) of PAs contain 5 - 20 nests and 4% (n = 14) of identified PAs are estimated to contain >20 nests. Just 1% (n = 5) of PAs are estimated to contain >40 nests; none is located in West Africa. Whilst ranging behavior of WhVs is currently unknown, 35% of PAs large enough to hold >20 nests are isolated by more than 100 km from other PAs. Spatially discrete and unpredictable mortality events such as poisoning pose major threats to small localized vulture populations and will accelerate ongoing local extinctions. Apart from reducing the threat of poisoning events, conservation actions promoting linkages between protected areas should be pursued. Identifying potential areas for assisted re-establishment via translocation offers the potential to expand the range of this species and alleviate risk.

  18. Fast, Capacious Disk Memory Device

    Science.gov (United States)

    Muller, Ronald M.

    1990-01-01

    Device for recording digital data on, and playing back data from, memory disks has high recording or playback rate and utilizes available recording area more fully. Two disks, each with own reading/writing head, used to record data at same time. Head on disk A operates on one of tracks numbered from outside in; head on disk B operates on track of same number in sequence from inside out. Underlying concept of device applicable to magnetic or optical disks.

  19. Vitamin K2 Ameliorates Damage of Blood Vessels by Glucocorticoid: a Potential Mechanism for Its Protective Effects in Glucocorticoid-induced Osteonecrosis of the Femoral Head in a Rat Model.

    Science.gov (United States)

    Zhang, Yuelei; Yin, Junhui; Ding, Hao; Zhang, Changqing; Gao, You-Shui

    2016-01-01

    Glucocorticoid has been reported to decrease blood vessel number and harm the blood supply in the femoral head, which is recognized to be an important mechanism of glucocorticoid-induced osteonecrosis of the femoral head (ONFH). To prevent glucocorticoid-induced ONFH, medication that promotes both bone formation and angiogenesis would be ideal. Vitamin K2 has been revealed to play an important role in bone metabolism; however, few studies have focused on the effect of Vitamin K2 on new vascular formation. Thus, this study aimed to investigate whether Vitamin K2 promoted new blood vessel formation in the presence of glucocorticoids, both in vitro and in vivo. The effect of Vitamin K2 on viability, migration, in vitro tube formation, and VEGF, vWF, CD31, KDR, Flt and PDGFB in EAhy926 incubated with or without dexamethasone were elucidated. VEGF, TGF-β and BMP-2, angiogenesis-related proteins secreted by osteoblasts, were also detected in the osteoblast-like cell line of MG63. In addition, blood vessels of the femoral head in rats administered with or without methylprednisolone and Vitamin K2 were evaluated using angiography and CD31 staining. In vitro studies showed that Vitamin K2 significantly protected endothelial cells from dexamethasone-induced apoptosis, promoted endothelial cell migration and in vitro tube formation. Angiogenesis-related proteins both in EAhy926 and MG63 were also upregulated by Vitamin K2 when cotreated with dexamethasone. In vivo studies showed enhanced blood vessel volume and CD31-positive staining cells in rats cotreated with VK2 and methylprednisolone compared to rats treated with methylprednisolone only. Collectively, Vitamin K2 has the ability to promote angiogenesis in vitro and to ameliorate vessels of the femoral head in glucocorticoid-treated rats in vivo, indicating that Vitamin K2 is a promising drug that may be used to prevent steroid-induced ONFH.

  20. X-ray face mask and chest shield device

    International Nuclear Information System (INIS)

    Moti, S.

    1981-01-01

    A protective face mask is designed to shield an x-ray technician or machine operator primarily from random secondary or scatter x-rays deflected towards his face, head and neck by the table, walls, equipment and other reflecting elements in an x-ray room or chamber. The face mask and chest shield device can be mounted on a patient's shoulders in reverse attitude to protect the back of a patient's head and neck from the x-ray beam. The face mask is relatively or substantially transparent and contains lead in combination with a plastic ionomer or comonomer, which to a degree absorbs or resists penetration of the random deflected secondary or scatter x-rays or the x-ray beam through the mask. The face mask is removably attachable to the chest shield for easy application of the device to and support upon the shoulders of the technician or the patient. (author)

  1. Electrochemical device

    Science.gov (United States)

    Grimes, Patrick G.; Einstein, Harry; Bellows, Richard J.

    1988-01-12

    A tunnel protected electrochemical device features channels fluidically communicating between manifold, tunnels and cells. The channels are designed to provide the most efficient use of auxiliary power. The channels have a greater hydraulic pressure drop and electrical resistance than the manifold. This will provide a design with the optimum auxiliary energy requirements.

  2. Head Start.

    Science.gov (United States)

    Greenman, Geri

    2000-01-01

    Discusses an art project in which students created drawings of mop heads. Explains that the approach of drawing was more important than the subject. States that the students used the chiaroscuro technique, used by Rembrandt and Caravaggio, in which light appears out of the darkness. (CMK)

  3. Study of protection devices against the effects of electric discharges inside a very high voltage generator: the Vivitron accelerator

    International Nuclear Information System (INIS)

    Nolot, E.

    1996-01-01

    The Vivitron tandem is a large electrostatic accelerator comprising a Van de Graaff generator designed to reach terminal voltages of around 30 MV. The machine is limited at rather lower nominal voltages (about 20 MV) due to the sensitivity of the insulating column structure to transient overvoltages. These are induced by electrical discharges in compressed SF 6 . This thesis first aims at analysing the fundamental reasons of electrical discharges in order to limit the probability of their occurrence. Then we simulate the transient overvoltages induced and present some improvements which may lead to a stable behaviour of the Vivitron at nominal voltages higher than 20 MV. Initially we deduce discharge onset voltages and actual breakdown field limitations in the different gap geometries from analysis of possible breakdown mechanisms in compressed SF 6 . In a second part, some electrical characteristics of the insulating column structure are measured at high voltage. Fast rising oscillating waves induced by sparking in the Vivitron, along with the associated energies,are determined in the third part. The last part deals with new surge protections of the insulating column structure. Spark gaps with precise onset voltage and optimized shielding electrodes are discussed. ZnO-based varistors designed for operation at very high fields have also been developed in order to reduce transient overvoltage values. (author)

  4. Methods for the Application of Programmable Logic Devices in Electronic Protection Systems for High Energy Particle Accelerators

    CERN Document Server

    Kwiatkowski, Maciej; Todd, Benjamin

    The present thesis was realised within the framework of the Doctoral Student programme at the European Organisation for Nuclear Research CERN, which is situated near Geneva. The aim of this thesis was to develop a method for reliable firmware implementation and to use that method to implement a new firmware for the Safe Machine Parameters (SMP) system. That system relies heavily on the Field Programmable Gate Arrays (FPGA) and it is one of the key machine protection systems of the Large Hadron Collider (LHC). The conception of the SMP hardware originates from the fully tested Beam Interlock System (BIS) being a result of another PhD thesis. For that reason the reliable SMP hardware was preserved unchanged. The first version of the SMP was ready for the LHC startup in the year 2008. Nevertheless the quality of the SMP firmware was objectionable. There were new requirements and therefore the SMP specification was extended. On that occasion it was decided that the existing SMP firmware will not be continued and ...

  5. Methods for the application of programmable logic devices in electronic protection systems for high energy particle accelerators

    CERN Document Server

    Kwiatkowski, M

    2014-01-01

    The present thesis was realised within the framework of the Doctoral Student programme at the European Organisation for Nuclear Research CERN, which is situated near Geneva. The aim of this thesis was to develop a method for reliable rmware implementation and to use that method to implement a new rmware for the Safe Machine Parameters (SMP) system. That system relies heavily on the Field Programmable Gate Arrays (FPGA) and it is one of the key machine protection systems of the Large Hadron Collider (LHC). The conception of the SMP hardware originates from the fully tested Beam Interlock System (BIS) being a result of another PhD thesis [1]. For that reason the reliable SMP hardware was preserved unchanged. The rst version of the SMP was ready for the LHC startup in the year 2008. Nevertheless the quality of the SMP rmware was objectionable. There were new requirements and therefore the SMP speci cation was extended. On that occasion it was decided that the existing SMP rmware will not be continued and that it...

  6. Scanning device for a spectrometer

    International Nuclear Information System (INIS)

    Ignat'ev, V.M.

    1982-01-01

    The invention belongs to scanning devices and is intended for spectrum scanning in spectral devices. The purpose of the invention is broadening of spectral scanning range. The device construction ensures the spectrum scanning range determined from revolution fractions to several revolutions of the monochromator drum head, any number of the drum head revolutions determined by integral number with addition of the drum revolution fractions with high degree of accuracy being possible

  7. The Association of the Heads of European Radiological Protection Competent Authorities (HERCA); La Asociacion de Autoridades Competentes en Proteccion Radiologica (HERCA)

    Energy Technology Data Exchange (ETDEWEB)

    Velasco, R.; RodrigueZ, M.; Amor, I.; Villanueva, I.; Martin Calvarro, J. M.; Aguado, M. D.; Sanchez, M.

    2012-07-01

    In 2007 a European association of regulatory authorities working in the field of radiological protection, known as HERCA, was set up with a view to harmonising the regulatory practices of the different countries, identifying new problems and providing agreed-to solutions. (Author)

  8. Flued head replacement alternatives

    International Nuclear Information System (INIS)

    Smetters, J.L.

    1987-01-01

    This paper discusses flued head replacement options. Section 2 discusses complete flued head replacement with a design that eliminates the inaccessible welds. Section 3 discusses alternate flued head support designs that can drastically reduce flued head installation costs. Section 4 describes partial flued head replacement designs. Finally, Section 5 discusses flued head analysis methods. (orig./GL)

  9. Topogram-based tube current modulation of head computed tomography for optimizing image quality while protecting the eye lens with shielding.

    Science.gov (United States)

    Lin, Ming-Fang; Chen, Chia-Yuen; Lee, Yuan-Hao; Li, Chia-Wei; Gerweck, Leo E; Wang, Hao; Chan, Wing P

    2018-01-01

    Background Multiple rounds of head computed tomography (CT) scans increase the risk of radiation-induced lens opacification. Purpose To investigate the effects of CT eye shielding and topogram-based tube current modulation (TCM) on the radiation dose received by the lens and the image quality of nasal and periorbital imaging. Material and Methods An anthropomorphic phantom was CT-scanned using either automatic tube current modulation or a fixed tube current. The lens radiation dose was estimated using cropped Gafchromic films irradiated with or without a shield over the orbit. Image quality, assessed using regions of interest drawn on the bilateral extraorbital areas and the nasal bone with a water-based marker, was evaluated using both a signal-to-noise ratio (SNR) and contrast-noise ratio (CNR). Two CT specialists independently assessed image artifacts using a three-point Likert scale. Results The estimated radiation dose received by the lens was significantly lower when barium sulfate or bismuth-antimony shields were used in conjunction with a fixed tube current (22.0% and 35.6% reduction, respectively). Topogram-based TCM mitigated the beam hardening-associated artifacts of bismuth-antimony and barium sulfate shields. This increased the SNR by 21.6% in the extraorbital region and the CNR by 7.2% between the nasal bones and extraorbital regions. The combination of topogram-based TCM and barium sulfate or bismuth-antimony shields reduced lens doses by 12.2% and 27.2%, respectively. Conclusion Image artifacts induced by the bismuth-antimony shield at a fixed tube current for lenticular radioprotection were significantly reduced by topogram-based TCM, which increased the SNR of the anthropomorphic nasal bones and periorbital tissues.

  10. Goniometer head

    International Nuclear Information System (INIS)

    Dzhazairov-Kakhramanov, V.; Berger, V.D.; Kadyrzhanov, K.K.; Zarifov, R.A.

    1994-01-01

    The goniometer head is an electromechanical instrument that performs the independent transfer of a testing sample on three coordinate axes (X, Y, Z) within limits of ±8 mm and independent rotation relative of these directions. The instrument comprises a sample holder, bellows component and three electrometer drives. The sample holder rotates around the axes X and Y, and is installed on the central arm which rotates around axis Z. One characteristic of this instrument is its independence which allows its use in any camera for researches in the field of radiation physics. 2 figs

  11. Posture of the head and pharyngeal swallowing

    International Nuclear Information System (INIS)

    Ekberg, O.

    1986-01-01

    Closure of the laryngeal vestibule during swallowing is important for protection of the airways. The present investigation included 53 patients with dysphagia examined cineradiographically with the head held in resting posture, flexion and extension. The ability to protect the airways by the downward movement of the epiglottis and by obliteration of the laryngeal vestibule was studied in different postures of the head. Of 35 patients with normal laryngeal obliteration with the head in resting position 10 showed a defective closure at swallowing in extension. In 18 patients with defective closure of the laryngeal vestibule in resting position 9 were improved on flexion and two on extension of the head. In one patient with defectie closure of the laryngeal vestibule in resting position swallowing in flexion showed an aggravated dysfunction. In our other patients the defective closure became more marked on extension. Four patients had less effective downward movement of the epiglottis with the head in extension. Of 10 patients with defective epiglottic movement with the head in resting position two were improved on tilting the head forwards. The results show that the position of the head influences the closure of the airways during swallowing. Patients with defective protection of the laryngeal vestibule should be instructed to swallow with the head tilted forwards. (orig.)

  12. Report by the work-group on 'safety of medical devices emitting ionizing radiations'. Articulation of radiation protection requirements of the 97/43/Euratom directive and IAEA recommendations with the essential requirements of the 93/42/CEE directive related to medical devices used in external radiotherapy

    International Nuclear Information System (INIS)

    2010-01-01

    As some dysfunctions and events had been reported in 2007 and 2008 in field of radiotherapy, this report aims at clarifying the articulation between the different European regulations concerning medical devices emitting ionizing radiations and radiation protection. The authors report a survey with device manufacturers, and analyze the content of the different regulations and recommendations. Then, the authors recommend and propose a set of actions related to the IAEA requirements and recommendations, to CE marking requirements, and to new radiation protection and safety requirements present in the Euratom directive

  13. The Impact of Hearing Protection Devices (HPDs on Blood Pressure in Workers Exposed to Noise: A Cross-sectional Study in a Textile Industry

    Directory of Open Access Journals (Sweden)

    Jafar Akbari

    2018-06-01

    Full Text Available Many studies have reported that exposure to workplace noise leads to increase in blood pressure. The aim of this study was to investigate the effect of hearing protection devices (HPDs including ear plug and ear muff on the systolic and diastolic blood pressures of workers exposed to workplace noise in a textile industry. A total of 120 male workers that exposed to 95 dB noise were investigated in this study. The systolic and diastolic blood pressures of the workers were measured for three situations of earplug, earmuff and earplug along earmuff applications. Data analyses were conducted through SPSS software (version 20 and statistical tests of ANOVA and Independent Sample Tests. The comparison of mean blood pressure in three situations showed that using ear muff had a significant effect on the systolic and diastolic blood pressures in the workers. Furthermore, the use of ear plug only had an effect on the systolic blood pressure. But, the application of ear muff caused to decrease in the systolic and diastolic blood pressures only in the third stage of the study. With regard to the results in this study, in order to control the blood pressure changes of the workers, it is recommended to use ear muff in the textile industry.

  14. Development of a new model of actinic enteritis in rats using a cobalt-60 open source and a protection device as a collimator

    Energy Technology Data Exchange (ETDEWEB)

    Nunes, Vinicius Rodrigues Taranto; Vidigal, Paula Vieira Teixeira; Barbuto, Rafael Calvao; Duval-Araujo, Ivana, E-mail: vivas1912@hotmail.com [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte (UFMG), MG (Brazil); Pereira, Marcio Tadeu; Ladeira, Luis Carlos Duarte [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2017-03-15

    Purpose: To describe a new model of actinic enteritis that does not use radiotherapy machines. Methods: Sixteen Wistar rats were divided into four groups, consisting of four animals each: control (group A), two weeks after irradiation (group B), five weeks after irradiation (group C) and eight weeks after irradiation (group D). Animals were given a 10Gy radiation from a Cobalt-60 natural source in a nuclear technology research center. Protections of the surrounding tissues were obtained through the usage of plumb devices with a hole in the center, which served as a collimator. We obtained irradiated and non-irradiated colons from each animal. Results: In group B we found an important inflammatory response in the irradiated colon, which appeared in a reduced way in group C and was minimal in group D, in which we found a relevant collagen submucosal deposition/fibrosis. In all groups, the non-irradiated colon had a lower pathological damage in comparison with the irradiated colon. Conclusion: We thus described an efficient and feasible technique for obtaining an animal model of actinic enteritis. (author)

  15. TREATMENT OF INTERNAL CAROTID ARTERY OCCLUSION USING PROXIMAL CEREBRAL PROTECTION DEVICE AND ITS EFFECT ON THE BLOOD PRESSURE DYNAMICS. CLINICAL CASE

    Directory of Open Access Journals (Sweden)

    F. В. Shukurov

    2018-01-01

    Full Text Available In 2016, according to the Ministry of Health of the Russian Federation, about 200 thousand people died from stroke. Strokes are considered as the main cause of disability of the population, causing huge economic damage to the country. One of the most common causes of ischemic stroke is atherosclerosis of the branches of the aortic arch. The most common localization of atherosclerotic plaques is the extracranial section of the carotid arteries – bifurcation and ostium of the common carotid artery and the internal carotid artery. Recanalization of occlusion of the internal carotid artery until recently was an insoluble task for interventional surgery due to the high risk of distal embolization. The invention and use of the proximal cerebral protection device, which ensure the complete cessation of blood flow, has changed the situation. Effect of carotid revascularization on arterial hypertension, due to the effect on the baroreceptors of the carotid plexus by balloon angioplasty, which leads to a reflex decrease in arterial pressure, is an additional advantage of the endovascular technique in some cases. This effect requires further study. One also needs to pay careful attention to the diagnosis and imaging of carotid artery lesions before procedure. This clinical case is the illustration that an adequate assessment of the risk factors for intraoperative complications allows to achieve maximum results of endovascular treatment.

  16. 21 CFR 882.4460 - Neurosurgical head holder (skull clamp).

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Neurosurgical head holder (skull clamp). 882.4460... holder (skull clamp). (a) Identification. A neurosurgical head holder (skull clamp) is a device used to clamp the patient's skull to hold head and neck in a particular position during surgical procedures. (b...

  17. Is HEADS in our heads?

    DEFF Research Database (Denmark)

    Boisen, Kirsten A; Hertz, Pernille Grarup; Blix, Charlotte

    2016-01-01

    contraception], Safety, Self-harm) interview is a feasible way of exploring health risk behaviors and resilience. OBJECTIVE: The purpose of this study was to evaluate how often HEADS topics were addressed according to young patients and staff in pediatric and adult outpatient clinics. METHODS: We conducted...... care professionals participated. We found only small reported differences between staff and young patients regarding whether home, education, and activity were addressed. However, staff reported twice the rate of addressing smoking, alcohol, illegal drugs, sexuality, and contraception compared to young...... patients. Young patients reported that smoking, alcohol, illegal drugs, sexuality, and contraception were addressed significantly more at adult clinics in comparison to pediatric clinics. After controlling for age, gender and duration of illness, according to young patients, adjusted odds ratios...

  18. Patient Dose During Carotid Artery Stenting With Embolic-Protection Devices: Evaluation With Radiochromic Films and Related Diagnostic Reference Levels According to Factors Influencing the Procedure

    International Nuclear Information System (INIS)

    D’Ercole, Loredana; Quaretti, Pietro; Cionfoli, Nicola; Klersy, Catherine; Bocchiola, Milena; Rodolico, Giuseppe; Azzaretti, Andrea; Lisciandro, Francesco; Cascella, Tommaso; Zappoli Thyrion, Federico

    2013-01-01

    To measure the maximum entrance skin dose (MESD) on patients undergoing carotid artery stenting (CAS) using embolic-protection devices, to analyze the dependence of dose and exposure parameters on anatomical, clinical, and technical factors affecting the procedure complexity, to obtain some local diagnostic reference levels (DRLs), and to evaluate whether overcoming DRLs is related to procedure complexity. MESD were evaluated with radiochromic films in 31 patients (mean age 72 ± 7 years). Five of 33 (15 %) procedures used proximal EPD, and 28 of 33 (85 %) procedures used distal EPD. Local DRLs were derived from the recorded exposure parameters in 93 patients (65 men and 28 women, mean age 73 ± 9 years) undergoing 96 CAS with proximal (33 %) or distal (67 %) EPD. Four bilateral lesions were included. MESD values (mean 0.96 ± 0.42 Gy) were FR ) were 269 Gy cm 2 , 28 minutes, and 251, respectively. Only simultaneous bilateral treatment was associated with KAP (odds ratio [OR] 10.14, 95 % confidence interval [CI] 1–102.7, p FR overexposures (OR 10.8, 95 % CI 1.1–109.5, p FR overexposure (OR 2.8, 95 % CI 1.1–7.4, p = 0.040). At multivariable analysis, stenosis ≥ 90 % (OR 2.8, 95 % CI 1.1–7.4, p = 0.040) and bilateral treatment (OR 10.8, 95 % CI 1.1–109.5, p = 0.027) were associated with overexposure for two or more parameters. Skin doses are not problematic in CAS with EPD because these procedures rarely lead to doses >2 Gy.

  19. Wheelchair control by head motion

    Directory of Open Access Journals (Sweden)

    Pajkanović Aleksandar

    2013-01-01

    Full Text Available Electric wheelchairs are designed to aid paraplegics. Unfortunately, these can not be used by persons with higher degree of impairment, such as quadriplegics, i.e. persons that, due to age or illness, can not move any of the body parts, except of the head. Medical devices designed to help them are very complicated, rare and expensive. In this paper a microcontroller system that enables standard electric wheelchair control by head motion is presented. The system comprises electronic and mechanic components. A novel head motion recognition technique based on accelerometer data processing is designed. The wheelchair joystick is controlled by the system’s mechanical actuator. The system can be used with several different types of standard electric wheelchairs. It is tested and verified through an experiment performed within this paper.

  20. Protection of patient In radiotherapy

    International Nuclear Information System (INIS)

    Deiyi, P.

    2013-04-01

    The purpose of this project is to clarify some aspects about protection of patient in radiotherapy. Therefore, some basic information about how the use of ionizing radiation in medicine has brought tremendous health benefits to the population globally, the requirement of radiation protection (Justification of practices, Dose limitation and Optimization of protection), and the deterministic and stochastic effects of radiation are presented. The aim of radiotherapy is to use ionizing radiation to cure diseases or make the symptoms of a disease less severe. Also presented are layout of a radiotherapy facility (controlled areas, supervised areas, mazes, door and interlocks, patient observation and communication, and warning sign and lights), radionuclides commonly used for radiation therapy and their main emissions, equipment and devices used in radiotherapy, aspect of protection of patient in radiotherapy such as: leakage test, source on/off, emergency buttons, radiation oncology team, treatment planning, room monitoring, equipment or for protection and Cobalt-60 unit stuck source. The advantages of brachytherapy, leakage from the treatment head and radiation incidents resulting from incorrect dose calibration are discussed. The importance of minimization dose exposure, by considering the basic principles of: time, distance and shielding are also stated. These principles prevent deterministic effects and limit stochastic effects of radiation. (author)

  1. Main radiation protection actions for medical personnel as primary responders front of an event with radiological dispersive device; Principais acoes de protecao radiologica para equipe medica como primeiros respondedores frente a um evento com dispositivo de dispersao radiologica

    Energy Technology Data Exchange (ETDEWEB)

    Duque, Hildanielle Ramos

    2015-07-01

    After the terrorist attack in New York, USA, in 2001, there was a worldwide concern about possible attacks using radioactive material in conventional detonators, called as Radiological Dispersal Device (RDD) or 'dirty bomb'. Several studies have been and are being made to form a global knowledge about this type of event. As until now, fortunately, there has not been an event with RDD, the Goiania Radiological Accident in Brazil, 1987, is used as a reference for decision-making. Several teams with technical experts should act in an event with RDD, but the medical staffs who respond quickly to the event must be properly protected from the harmful effects of radiation. Based on the radiological protection experts performance during the Goiania accident and the knowledge from lessons learned of many radiological accidents worldwide, this work presents an adaptation of the radiation protection actions for an event with RDD that helps a medical team as primary responders. The following aspects are presented: the problem of radioactive contamination from the explosion of the device in underground environment, the actions of the first responders and evaluation of health radiation effects. This work was based on specialized articles and papers about radiological accidents and RDD; as well as personal communication and academic information of the Institute of Radiation Protection and Dosimetry. The radiation protection actions, adapted to a terrorist attack event with RDD, have as a scenario a subway station in the capital. The main results are: the use of the basic radiation protection principle of time because there is no condition to take care of a patient keeping distance or using a shielding; the use of full appropriate protection cloths for contaminating materials ensuring the physical safety of professionals, and the medical team monitoring at the end of a medical procedure, checking for surface contamination. The main conclusion is that all medical actions

  2. Heading and head injuries in soccer.

    Science.gov (United States)

    Kirkendall, D T; Jordan, S E; Garrett, W E

    2001-01-01

    In the world of sports, soccer is unique because of the purposeful use of the unprotected head for controlling and advancing the ball. This skill obviously places the player at risk of head injury and the game does carry some risk. Head injury can be a result of contact of the head with another head (or other body parts), ground, goal post, other unknown objects or even the ball. Such impacts can lead to contusions, fractures, eye injuries, concussions or even, in rare cases, death. Coaches, players, parents and physicians are rightly concerned about the risk of head injury in soccer. Current research shows that selected soccer players have some degree of cognitive dysfunction. It is important to determine the reasons behind such deficits. Purposeful heading has been blamed, but a closer look at the studies that focus on heading has revealed methodological concerns that question the validity of blaming purposeful heading of the ball. The player's history and age (did they play when the ball was leather and could absorb significant amounts of water), alcohol intake, drug intake, learning disabilities, concussion definition and control group use/composition are all factors that cloud the ability to blame purposeful heading. What does seem clear is that a player's history of concussive episodes is a more likely explanation for cognitive deficits. While it is likely that the subconcussive impact of purposeful heading is a doubtful factor in the noted deficits, it is unknown whether multiple subconcussive impacts might have some lingering effects. In addition, it is unknown whether the noted deficits have any affect on daily life. Proper instruction in the technique is critical because if the ball contacts an unprepared head (as in accidental head-ball contacts), the potential for serious injury is possible. To further our understanding of the relationship of heading, head injury and cognitive deficits, we need to: learn more about the actual impact of a ball on the

  3. Study on the influence of package parasitics and substrate resistance on the Charged Device Model(CDM) failure levels - possible protection methodology

    NARCIS (Netherlands)

    Sowariraj, M.S.B.; Smedes, Theo; Salm, Cora; Mouthaan, A.J.; Kuper, F.G.

    2003-01-01

    Charged Device Model (CDM) type of Electrostatic Discharge (ESD) stress events are becoming the major reason for field returns in the Integrated Circuit (IC) industry especially with downscaling of device dimensions and increased usage of automated handlers. In the case of CDM stress, the IC is both

  4. Patient Dose During Carotid Artery Stenting With Embolic-Protection Devices: Evaluation With Radiochromic Films and Related Diagnostic Reference Levels According to Factors Influencing the Procedure

    Energy Technology Data Exchange (ETDEWEB)

    D' Ercole, Loredana, E-mail: l.dercole@smatteo.pv.it [Fondazione IRCCS Policlinico San Matteo, Department of Medical Physics (Italy); Quaretti, Pietro; Cionfoli, Nicola [Fondazione IRCCS Policlinico San Matteo, Department of Radiology (Italy); Klersy, Catherine [Fondazione IRCCS Policlinico San Matteo, Biometry and Clinical Epidemiology Service, Research Department, (Italy); Bocchiola, Milena [Fondazione IRCCS Policlinico San Matteo, Department of Medical Physics (Italy); Rodolico, Giuseppe; Azzaretti, Andrea [Fondazione IRCCS Policlinico San Matteo, Department of Radiology (Italy); Lisciandro, Francesco [Fondazione IRCCS Policlinico San Matteo, Department of Medical Physics (Italy); Cascella, Tommaso; Zappoli Thyrion, Federico [Fondazione IRCCS Policlinico San Matteo, Department of Radiology (Italy)

    2013-04-15

    To measure the maximum entrance skin dose (MESD) on patients undergoing carotid artery stenting (CAS) using embolic-protection devices, to analyze the dependence of dose and exposure parameters on anatomical, clinical, and technical factors affecting the procedure complexity, to obtain some local diagnostic reference levels (DRLs), and to evaluate whether overcoming DRLs is related to procedure complexity. MESD were evaluated with radiochromic films in 31 patients (mean age 72 {+-} 7 years). Five of 33 (15 %) procedures used proximal EPD, and 28 of 33 (85 %) procedures used distal EPD. Local DRLs were derived from the recorded exposure parameters in 93 patients (65 men and 28 women, mean age 73 {+-} 9 years) undergoing 96 CAS with proximal (33 %) or distal (67 %) EPD. Four bilateral lesions were included. MESD values (mean 0.96 {+-} 0.42 Gy) were <2 Gy without relevant dependence on procedure complexity. Local DRL values for kerma area product (KAP), fluoroscopy time (FT), and number of frames (N{sub FR}) were 269 Gy cm{sup 2}, 28 minutes, and 251, respectively. Only simultaneous bilateral treatment was associated with KAP (odds ratio [OR] 10.14, 95 % confidence interval [CI] 1-102.7, p < 0.05) and N{sub FR} overexposures (OR 10.8, 95 % CI 1.1-109.5, p < 0.05). Type I aortic arch decreased the risk of FT overexposure (OR 0.4, 95 % CI 0.1-0.9, p = 0.042), and stenosis {>=} 90 % increased the risk of N{sub FR} overexposure (OR 2.8, 95 % CI 1.1-7.4, p = 0.040). At multivariable analysis, stenosis {>=} 90 % (OR 2.8, 95 % CI 1.1-7.4, p = 0.040) and bilateral treatment (OR 10.8, 95 % CI 1.1-109.5, p = 0.027) were associated with overexposure for two or more parameters. Skin doses are not problematic in CAS with EPD because these procedures rarely lead to doses >2 Gy.

  5. MODELING PROTECTIVE DEVICES FOR DISTRIBUTION SYSTEMS WITH DISTRIBUTED GENERATION USING AN EMTP-TYPE TOOL REPRESENTACIÓN EN EMTP DE DISPOSITIVOS DE PROTECCIÓN DE REDES DE DISTRIBUCIÓN CON GENERACIÓN DISTRIBUIDA

    Directory of Open Access Journals (Sweden)

    Juan A Martínez-Velasco

    2010-08-01

    Full Text Available This paper presents the main features of a library of modules for representation of protective devices of distribution networks with distributed generation (DG. The impact of distributed generation in a distribution network depends, among other aspects, on the design of the protection system and the coordination between the different protective devices. The presence of distributed generation changes the radial nature of distribution systems and affects the performance of the protection system. This document discusses the present protection practices for distribution systems and DG interties, describes the implementation of protective devices (circuit breakers, relays, reclosers, fuses, sectionalizers in an EMTP-type tool, and presents some simulation results whose main goal is to analyze the impact of synchronous machine-based embedded generators on the coordination between the different types of protective devices.Este artículo presenta las características principales de una librería de módulos desarrollada para representar dispositivos de protección de una red de distribución de energía eléctrica con generación distribuida (GD. El impacto de la generación distribuida depende, entre otros aspectos, del diseño del sistema de protección, y de la coordinación entre los diferentes dispositivos de protección. La presencia de unidades generadoras altera el flujo radial inherente a un sistema de distribución y afecta al comportamiento del sistema de protección. Este trabajo presenta una introducción de los sistemas de protección de las redes de distribución y de la interconexión de unidades generadoras, describe la implantación de dispositivos de protección (interruptores, relés, reenganchadores, fusibles, seccionalizadores en un programa tipo EMTP, y presenta algunos resultados obtenidos mediante simulación, cuyo principal objetivo es ilustrar el impacto que la generación distribuida basada en generadores síncronos puede

  6. Head Trauma: First Aid

    Science.gov (United States)

    First aid Head trauma: First aid Head trauma: First aid By Mayo Clinic Staff Most head trauma involves injuries that are minor and don't require ... 21, 2015 Original article: http://www.mayoclinic.org/first-aid/first-aid-head-trauma/basics/ART-20056626 . Mayo ...

  7. Device for cutting protrusions

    Science.gov (United States)

    Bzorgi, Fariborz M [Knoxville, TN

    2011-07-05

    An apparatus for clipping a protrusion of material is provided. The protrusion may, for example, be a bolt head, a nut, a rivet, a weld bead, or a temporary assembly alignment tab protruding from a substrate surface of assembled components. The apparatus typically includes a cleaver having a cleaving edge and a cutting blade having a cutting edge. Generally, a mounting structure configured to confine the cleaver and the cutting blade and permit a range of relative movement between the cleaving edge and the cutting edge is provided. Also typically included is a power device coupled to the cutting blade. The power device is configured to move the cutting edge toward the cleaving edge. In some embodiments the power device is activated by a momentary switch. A retraction device is also generally provided, where the retraction device is configured to move the cutting edge away from the cleaving edge.

  8. Head and neck cancer

    International Nuclear Information System (INIS)

    Vogl, S.E.

    1988-01-01

    This book contains 10 chapters. Some of the titles are: Combined Surgical Resection and Irradiation for Head and Neck Cancers; Analysis of Radiation Therapy Oncology Group Head and Neck Database: Identification of Prognostic Factors and the Re-evaluation of American Joint Committee Stages; Combined Modality Approach to Head and Neck Cancer; Induction Combination Chemotherapy of Regionally Advanced Head and Neck Cancer; and Outcome after Complete Remission to Induction Chemotherapy in Head and Neck Cancer

  9. Head and eye movement as pointing modalities for eyewear computers

    DEFF Research Database (Denmark)

    Jalaliniya, Shahram; Mardanbeigi, Diako; Pederson, Thomas

    2014-01-01

    examined using head and eye movements to point on a graphical user interface of a wearable computer. The performance of users in head and eye pointing has been compared with mouse pointing as a baseline method. The result of our experiment showed that the eye pointing is significantly faster than head......While the new generation of eyewear computers have increased expectations of a wearable computer, providing input to these devices is still challenging. Hand-held devices, voice commands, and hand gestures have already been explored to provide input to the wearable devices. In this paper, we...

  10. Rotational Acceleration during Head Impact Resulting from Different Judo Throwing Techniques

    OpenAIRE

    MURAYAMA, Haruo; HITOSUGI, Masahito; MOTOZAWA, Yasuki; OGINO, Masahiro; KOYAMA, Katsuhiro

    2014-01-01

    Most severe head injuries in judo are reported as acute subdural hematoma. It is thus necessary to examine the rotational acceleration of the head to clarify the mechanism of head injuries. We determined the rotational acceleration of the head when the subject is thrown by judo techniques. One Japanese male judo expert threw an anthropomorphic test device using two throwing techniques, Osoto-gari and Ouchigari. Rotational and translational head accelerations were measured with and without an ...

  11. Automated recognition of rear seat occupants' head position using Kinect™ 3D point cloud.

    Science.gov (United States)

    Loeb, Helen; Kim, Jinyong; Arbogast, Kristy; Kuo, Jonny; Koppel, Sjaan; Cross, Suzanne; Charlton, Judith

    2017-12-01

    Child occupant safety in motor-vehicle crashes is evaluated using Anthropomorphic Test Devices (ATD) seated in optimal positions. However, child occupants often assume suboptimal positions during real-world driving trips. Head impact to the seat back has been identified as one important injury causation scenario for seat belt restrained, head-injured children (Bohman et al., 2011). There is therefore a need to understand the interaction of children with the Child Restraint System to optimize protection. Naturalistic driving studies (NDS) will improve understanding of out-of-position (OOP) trends. To quantify OOP positions, an NDS was conducted. Families used a study vehicle for two weeks during their everyday driving trips. The positions of rear-seated child occupants, representing 22 families, were evaluated. The study vehicle - instrumented with data acquisition systems, including Microsoft Kinect™ V1 - recorded rear seat occupants in 1120 driving 26 trips. Three novel analytical methods were used to analyze data. To assess skeletal tracking accuracy, analysts recorded occurrences where Kinect™ exhibited invalid head recognition among a randomly-selected subset (81 trips). Errors included incorrect target detection (e.g., vehicle headrest) or environmental interference (e.g., sunlight). When head data was present, Kinect™ was correct 41% of the time; two other algorithms - filtering for extreme motion, and background subtraction/head-based depth detection are described in this paper and preliminary results are presented. Accuracy estimates were not possible because of their experimental nature and the difficulty to use a ground truth for this large database. This NDS tested methods to quantify the frequency and magnitude of head positions for rear-seated child occupants utilizing Kinect™ motion-tracking. This study's results informed recent ATD sled tests that replicated observed positions (most common and most extreme), and assessed the validity of child

  12. Head injury - first aid

    Science.gov (United States)

    ... medlineplus.gov/ency/article/000028.htm Head injury - first aid To use the sharing features on this page, ... a concussion can range from mild to severe. First Aid Learning to recognize a serious head injury and ...

  13. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... the head uses special x-ray equipment to help assess head injuries, severe headaches, dizziness, and other ... aneurysm, bleeding, stroke and brain tumors. It also helps your doctor to evaluate your face, sinuses, and ...

  14. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... for Brain Tumors Radiation Therapy for Head and Neck Cancer Others American Stroke Association National Stroke Association ... Computer Tomography (CT) Safety During Pregnancy Head and Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine ...

  15. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view ... Safety Images related to Computed Tomography (CT) - Head Videos related to Computed Tomography (CT) - Head Sponsored by ...

  16. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... the limitations of CT Scanning of the Head? What is CT Scanning of the Head? Computed tomography, ... than regular radiographs (x-rays). top of page What are some common uses of the procedure? CT ...

  17. Protective effect of blue-light shield eyewear for adults against light pollution from self-luminous devices used at night.

    Science.gov (United States)

    Ayaki, Masahiko; Hattori, Atsuhiko; Maruyama, Yusuke; Nakano, Masaki; Yoshimura, Michitaka; Kitazawa, Momoko; Negishi, Kazuno; Tsubota, Kazuo

    2016-01-01

    We investigated sleep quality and melatonin in 12 adults who wore blue-light shield or control eyewear 2 hours before sleep while using a self-luminous portable device, and assessed visual quality for the two eyewear types. Overnight melatonin secretion was significantly higher after using the blue-light shield (P light shield (P light shield as providing acceptable visual quality.

  18. Head impact in a snowboarding accident.

    Science.gov (United States)

    Bailly, N; Llari, M; Donnadieu, T; Masson, C; Arnoux, P J

    2017-09-01

    To effectively prevent sport traumatic brain injury (TBI), means of protection need to be designed and tested in relation to the reality of head impact. This study quantifies head impacts during a typical snowboarding accident to evaluate helmet standards. A snowboarder numerical model was proposed, validated against experimental data, and used to quantify the influence of accident conditions (speed, snow stiffness, morphology, and position) on head impacts (locations, velocities, and accelerations) and injury risk during snowboarding backward falls. Three hundred twenty-four scenarios were simulated: 70% presented a high risk of mild TBI (head peak acceleration >80 g) and 15% presented a high risk of severe TBI (head injury criterion >1000). Snow stiffness, speed, and snowboarder morphology were the main factors influencing head impact metrics. Mean normal head impact speed (28 ± 6 km/h) was higher than equivalent impact speed used in American standard helmet test (ASTM F2040), and mean tangential impact speed, not included in standard tests, was 13.8 (±7 km/h). In 97% of simulated impacts, the peak head acceleration was below 300 g, which is the pass/fail criteria used in standard tests. Results suggest that initial speed, impacted surface, and pass/fail criteria used in helmet standard performance tests do not fully reflect magnitude and variability of snowboarding backward-fall impacts. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  19. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special x-ray ... What is CT Scanning of the Head? Computed tomography, more commonly known as a CT or CAT ...

  20. Eye Protection

    OpenAIRE

    Pashby, Tom

    1986-01-01

    Eye injuries frequently occur in the home, at work and at play. Many result in legally blind eyes, and most are preventable. Awareness of potential hazards is essential to preventing eye injuries, particularly in children. In addition, protective devices must be used appropriately. We have developed eye protectors that have proved effective in reducing both the overall incidence and the severity of sports eye injuries.

  1. Comparison between Japanese and French interstitial brachytherapy for head and neck cancer

    International Nuclear Information System (INIS)

    Nose, Takayuki; Koizumi, Masahiko; Nishiyama, Kinji; Inoue, Toshihiko

    2001-01-01

    Interstitial brachytherapy is the optimal radiotherapy modality for head and neck cancer because the highest dose conformity can be achieved, and implanted tubes can move synchronously with the tumor movement. Compared with radical surgery, interstitial brachytherapy can achieve equivalent local control with less morbidity and less functional deficit. In Japan, because of technical limitations, interstitial brachytherapy has been confined to treatment of small tongue cancers. To improve our head and neck cancer treatment, technical limitations should be eliminated and a wider indication for interstitial brachytherapy should be achieved. In France, interstitial brachytherapy has been technically more developed and widely indicated than in Japan. We analyzed the differences between Japanese (Osaka) and French (Lyon and Nancy) techniques, to improve our interstitial brachytherapy. Implant devices and techniques: French applicators (Longcip 1) are more flexible and more suitable for loop techniques of the soft palate, the base of the tongue, and the vallecula, than applicators available in Japan. Various implant techniques are established especially for the oropharynx in France. Mandibular protection: Lead blocks used in France can more effectively shield the mandible than our silicone spacers. We showed the dosimetric results in an experimental treatment setting. Dose specification: The five-mm dose specification method used in Japan can work only for easy cases, such as small oral tongue cancers and mouth floor cancers. For complicated implants, such as for the oropharynx, the CTV-based dose specification method used in France is essential for sufficient irradiation. Indications: The indication for head and neck interstitial brachytherapy in Japan is limited mostly to small oral tongue cancers. The indication in France is wider, including the oral cavity, the oropharynx, and postoperative cases. We can refine our head and neck cancer treatment if we combine French

  2. Evaluation of the Scott Aviation Portable Protective Breathing Device for contaminant leakage as prescribed by FAA Action Notice A-8150.2.

    Science.gov (United States)

    1989-11-01

    Two types of crewmember protective breathing equipment (PBE) were performance tested for compliance with Action Notice A-8150.2 at ground level (- 1,300 feet) and 8,000 feet altitude. PBE 1 was a 'hood with oral-nasal mask,' which used potassium supe...

  3. Head, Neck, and Oral Cancer

    Medline Plus

    Full Text Available ... Head and Neck Pathology Oral, Head and Neck Pathology Close to 49,750 Americans will be diagnosed ... Head and Neck Pathology Oral, Head and Neck Pathology Close to 49,750 Americans will be diagnosed ...

  4. Act to keep patients safe: device-related adverse event reporting.

    Science.gov (United States)

    Schoem, Scott R; Shah, Udayan K

    2010-05-01

    Primum non nocere- "Above all do no harm." Since the first year of medical school, we have all heard and spoken this dictum countless times. Translating this dictum into action may present challenges in our daily practice. Every day, clinicians must distinguish between scientific evidence, clinical experience, and marketing claims by industry vendors of improved efficacy and safety regarding medical devices. Adverse event reporting and device failure notification are generally laid out well in hospital practice settings. Reporting beyond the local level takes on a new dimension for most surgeons. Perceived stigma from peers and corporations, lack of confidentiality, and cynicism regarding protective actions for patients should not limit one from "raising the alarm" when concerns arise about device safety or performance. This commentary aims to explain the process for reporting device-related adverse events. Copyright 2010 American Academy of Otolaryngology-Head and Neck Surgery Foundation. Published by Mosby, Inc. All rights reserved.

  5. Protection devices in the transmission grids, German practice. Typical protection concepts in Germany's power transmission lines; Schutzsysteme im Uebertragungsnetz, deutsche Praxis. Typische Schutzkonzepte im deutschen Uebertragungsnetz

    Energy Technology Data Exchange (ETDEWEB)

    Herrmann, Hans-Joachim [Siemens AG, Nuernberg (Germany). Sektor Energy, Energy Automation; Ludwig, Andrea [50 Hertz Transmission GmbH, Berlin (Germany). Schutztechnik, Anlagenmanagement; Kuehn, Holger [Tennet TSO GmbH, Bayreuth (Germany). Schutztechnik, Assetmanagement/Umspannwerke; Oechsle, Fred [EnBW Regional AG, Stuttgart (Germany). Netzschutz, Netzservice - Projekte Strom

    2011-04-18

    The contribution presents typical protection concepts for power grids. Solutions for power plant feed-in, bus bar, transmission lines and coupling transformer are explained. General information is provided on triggering concepts, on the design of d.c. power supply, selection of current inverters, and other subjects.

  6. Blocking device especially for circulating pumps

    International Nuclear Information System (INIS)

    Susil, J.; Vychodil, V.; Lorenc, P.

    1976-01-01

    The claim of the invention is a blocking device which blocks reverse flow occurring after the shutdown of circulating pumps, namely in the operation of nuclear power plants or in pumps with a high delivery head. (F.M.)

  7. X-ray face mask and bib device

    International Nuclear Information System (INIS)

    Forshee, D.J.; Moti, S.

    1984-01-01

    This invention provides an improved device for shielding and protecting a person against direct and scattered x-ray radiation to the face, head and neck to be worn on the shoulders. The device includes a radiation-shielding face mask having a lead-filled frame and a lead-containing transparent radiation-shielding lens mounted in the frame. The frame is supported upon the shoulders. A first portion of the frame extends generally inward below the chin of the person, and a second portion of the frame extends generally vertically from an inward portion of the first portion and generally rearwardly adjacent to at least one lateral side of the neck of the person

  8. Industrial fabrication of an optical security device for document protection using plasmon resonant transmission through a thin corrugated metallic film embedded on a plastic foil

    Science.gov (United States)

    Sauvage-Vincent, Jean; Jourlin, Yves; Tonchev, Svetlen; Veillas, Colette; Claude, Pedri; Parriaux, Olivier

    2012-06-01

    Known since a long time in polymer banknotes and presented in the few years in paper banknotes, the principle of windowed documents has been currently extended to ID documents. We present an innovative solution which combines resonant transmission and Zero Order Device technologies and which is dedicated to improve windows in terms of the overt security level. With this R&D program, Hologram Industries targeted to obtain an overt visual security device that should be readily checked in transmission in the same manner as the established paper watermark. The proposed solution is based on the propagation of resonant modes in a thin continuous corrugated metallic layer embedded (encapsulated) between two dielectric layers of near equal refractive index. The mode of most interest is the Long Range Plasmon Mode. The coupling condition to the Long Range Mode is principally related to the corrugation, the metal layer thickness and the index of the two dielectric layers. If the condition of the mode excitation through the grating is fulfilled, a predetermined wavelength will be coupled to the Long Range Plasmon Mode. This mode will propagate at each metal/dielectric interface with a low loss and will concentrate the electric field inside the metal layer. This effect of coupling enables the transmission of a peak at this wavelength through the metallic layer. It defines the so called "extraordinary resonant transmission".

  9. Antipredatory function of head shape for vipers and their mimics.

    Directory of Open Access Journals (Sweden)

    Janne K Valkonen

    Full Text Available Most research into the adaptive significance of warning signals has focused on the colouration and patterns of prey animals. However, behaviour, odour and body shape can also have signal functions and thereby reduce predators' willingness to attack defended prey. European vipers all have a distinctive triangular head shape; and they are all venomous. Several non-venomous snakes, including the subfamily Natricinae, commonly flatten their heads (also known as head triangulation when disturbed. The adaptive significance of this potential behavioural mimicry has never been investigated.We experimentally tested if the triangular head shape typical of vipers offers protection against predation. We compared the predation pressure of free-ranging predators on artificial snakes with triangular-shaped heads against the pressure on replicas with narrow heads. Snakes of both head types had either zigzag patterned bodies, typical of European vipers, or plain (patternless bodies. Plain snakes with narrower Colubrid-like heads suffered significantly higher predation by raptors than snakes with triangular-shaped heads. Head shape did not, however, have an additive effect on survival in zigzag-patterned snakes, suggesting that species which differ from vipers in colouration and pattern would benefit most from behavioural mimicry. Our results demonstrate that the triangular head shape typical of vipers can act as a warning signal to predators. We suggest that head-shape mimicry may be a more common phenomenon among more diverse taxa than is currently recognised.

  10. Safety device for nuclear reactor

    International Nuclear Information System (INIS)

    Jacquelin, Roland.

    1977-01-01

    This invention relates to a safety device for a nuclear reactor, particularly a liquid metal (generally sodium) cooled fast reactor. This safety device includes an absorbing element with a support head connected by a disconnectable connector formed by the armature of an electromagnet at the end of an axially mobile vertical control rod. This connection is so designed that in the event of it becoming disconnected, the absorbing element gravity slides in a passage through the reactor core into an open container [fr

  11. Protection and isolation device for pipe maintenance, particularly for pipes of nuclear power plants. Dispositif d'isolement et de protection pour intervention sur tuyauterie, notamment tuyauterie de centrale nucleaire

    Energy Technology Data Exchange (ETDEWEB)

    Dohlen, G.; Le Marquis, J.C.; Oberlin, C.

    1984-09-28

    The device is aimed to be introduced and deployed inside a pipe, to collect and remove debris (dust or scraps) or foreign bodies, resulting from the work especially maintenance work being carried out. It comprises a central mast, a deformable sealing joint, mating with the interior of the conduit; a number of arms regularly distributed around the mast, which can be folded back against the mast, to permit introduction of the device into the conduit, each arm supporting the joint at one end and being pivoted on a common base at its other end; mechanical compression apparatus, connected to the mast and the base for deploying the apparatus, and flattening the joint against the interior surface of the conduit to which it is mated; and two sheets of material, each supported at its periphery by the joint, at least one of the sheets being suitable for isolating in sealed manner the space volumes which it delimits. The invention applies to maintenance operations for which the pipes have to be maintained under a controlled inert gas atmosphere, such as sodium circuits maintenance of nuclear power plants.

  12. Head CT scan

    Science.gov (United States)

    ... scan - orbits; CT scan - sinuses; Computed tomography - cranial; CAT scan - brain ... head size in children Changes in thinking or behavior Fainting Headache, when you have certain other signs ...

  13. Bottom head assembly

    International Nuclear Information System (INIS)

    Fife, A.B.

    1998-01-01

    A bottom head dome assembly is described which includes, in one embodiment, a bottom head dome and a liner configured to be positioned proximate the bottom head dome. The bottom head dome has a plurality of openings extending there through. The liner also has a plurality of openings extending there through, and each liner opening aligns with a respective bottom head dome opening. A seal is formed, such as by welding, between the liner and the bottom head dome to resist entry of water between the liner and the bottom head dome at the edge of the liner. In the one embodiment, a plurality of stub tubes are secured to the liner. Each stub tube has a bore extending there through, and each stub tube bore is coaxially aligned with a respective liner opening. A seat portion is formed by each liner opening for receiving a portion of the respective stub tube. The assembly also includes a plurality of support shims positioned between the bottom head dome and the liner for supporting the liner. In one embodiment, each support shim includes a support stub having a bore there through, and each support stub bore aligns with a respective bottom head dome opening. 2 figs

  14. The development of display device for radioactive information using wireless communication

    International Nuclear Information System (INIS)

    Kim, Jung Taek; Park, Won Man; Lee, Bong Jae; Lim, Yoo Chung

    1998-06-01

    The improvement in the nuclear industry makes that it is important to protect personnel and equipment form radiation, because they have many chance to treat radioactive material. The head office on a prevention and an emergency measure for a radioactive release is necessary. In this study, display device for radioactive information using wireless communication has been developed to display a radioactivity using radio frequency modem. Therefore, the unlocated head office can be operated in a portable environment using a notebook PC or a compact display device. Korea Atomic Energy Research Institute, which runs a research reactor, HANARO, needs the head office on a prevention and an emergency measure for a radioactive release. The display device for radioactive information using wireless communication to be developed in this study, can be used to the head office as a display device not to pay additional cost. This study has developed the display device for radioactive information using wireless communication, Remote Radiation Display System(RRDS), which transmits every 10 second a radioactive information to be displayed to RMT(Radiation Monitoring Terminal) of Radiation Monitoring System in HANARO. In this study, first, a configuration of hardware and software in HANARO RMS has been reviewed. Second, a RS-2322C serial communication program to transmit a radioactive information in HARARO RMS to RRDS using radio frequency modem has been developed. Finally, a RS-2322C serial communication program to receive a radioactive information in HANARO RMS from RRDS using radio frequency modem and GUI program to display the received information to RRDS has been developed. (author). 19 refs., 3 tabs., 25 figs

  15. Techniques in cerebral protection.

    Science.gov (United States)

    Fanelli, Fabrizio; Bezzi, Mario; Boatta, Emanuele; Passariello, Roberto

    2006-10-01

    Carotid angioplasty and stenting is a valid alternative option to conventional carotid endarterectomy in the treatment of carotid artery stenosis. During the stenting process, however, distal embolization can occur with neurological consequences. To avoid this, cerebral protection devices have been introduced. Three principal types of protection system have been developed: distal balloon occlusion, distal filters and proximal protection with or without reversal of flow. As protection devices became the focus of interest by manufactures and physicians, several trials are going on worldwide to analyze the characteristics of each of them and to evaluate their efficacy to reduce the rate of distal embolization.

  16. Porcine head response to blast.

    Science.gov (United States)

    Shridharani, Jay K; Wood, Garrett W; Panzer, Matthew B; Capehart, Bruce P; Nyein, Michelle K; Radovitzky, Raul A; Bass, Cameron R 'dale'

    2012-01-01

    Recent studies have shown an increase in the frequency of traumatic brain injuries related to blast exposure. However, the mechanisms that cause blast neurotrauma are unknown. Blast neurotrauma research using computational models has been one method to elucidate that response of the brain in blast, and to identify possible mechanical correlates of injury. However, model validation against experimental data is required to ensure that the model output is representative of in vivo biomechanical response. This study exposes porcine subjects to primary blast overpressures generated using a compressed-gas shock tube. Shock tube blasts were directed to the unprotected head of each animal while the lungs and thorax were protected using ballistic protective vests similar to those employed in theater. The test conditions ranged from 110 to 740 kPa peak incident overpressure with scaled durations from 1.3 to 6.9 ms and correspond approximately with a 50% injury risk for brain bleeding and apnea in a ferret model scaled to porcine exposure. Instrumentation was placed on the porcine head to measure bulk acceleration, pressure at the surface of the head, and pressure inside the cranial cavity. Immediately after the blast, 5 of the 20 animals tested were apneic. Three subjects recovered without intervention within 30 s and the remaining two recovered within 8 min following respiratory assistance and administration of the respiratory stimulant doxapram. Gross examination of the brain revealed no indication of bleeding. Intracranial pressures ranged from 80 to 390 kPa as a result of the blast and were notably lower than the shock tube reflected pressures of 300-2830 kPa, indicating pressure attenuation by the skull up to a factor of 8.4. Peak head accelerations were measured from 385 to 3845 G's and were well correlated with peak incident overpressure (R(2) = 0.90). One SD corridors for the surface pressure, intracranial pressure (ICP), and head acceleration are

  17. Mobile device security for dummies

    CERN Document Server

    Campagna, Rich; Krishnan, Ashwin

    2011-01-01

    The information you need to avoid security threats on corporate mobile devices Mobile devices have essentially replaced computers for corporate users who are on the go and there are millions of networks that have little to no security. This essential guide walks you through the steps for securing a network and building a bulletproof framework that will protect and support mobile devices in the enterprise. Featuring real-world case scenarios, this straightforward guide shares invaluable advice for protecting mobile devices from the loss of sensitive and confidential corporate informati

  18. Protective clothing

    International Nuclear Information System (INIS)

    Winnett, G.F.

    1979-01-01

    A protective suit used for isolating its wearer from radioactively contaminated areas is described in three parts. The first part includes the covering for the wearer's head, arms and upper body and at the waist is releasably fitted around an opening into the contaminated area. The second part includes the legs of the suit and is releasably connectible to the first part of the suit to enclose the wearer who is then supplied with air through an umbilical pipe. A further part surrounds the second part and is releasably connectible to it, enclosing a space between the parts. This further part is also releasably connectible to the opening at the waist to prevent egress from the contaminated area. The releasable connections between the parts may be bayonet type fittings or may be rotating T-shaped projections which engage in T-shaped grooves. (author)

  19. Naturalistic driving study of rear seat child occupants: Quantification of head position using a Kinect™ sensor.

    Science.gov (United States)

    Arbogast, Kristy B; Kim, Jinyong; Loeb, Helen; Kuo, Jonny; Koppel, Sjaan; Bohman, Katarina; Charlton, Judith L

    2016-09-01

    time in a naturalistic setting, the range of head positions for child occupants was quantified. More variability was observed for those restrained in booster seats and seat belts than for those in FFCRS. The role of activities, in particular interactions with electronic devices, on head position was notable; this will be the subject of further analysis in other components of the broader study. These data can lead to solutions for optimal protection for occupants who assume positions that differ from prescribed, optimal testing positions.

  20. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special x-ray equipment ... story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content ...

  1. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Computed tomography (CT) of the head uses special x-ray equipment to help assess head injuries, severe headaches, ... is a diagnostic medical test that, like traditional x-rays, produces multiple images or pictures of the inside ...

  2. Head Impact Biomechanics in Women's College Soccer.

    Science.gov (United States)

    Lynall, Robert C; Clark, Michael D; Grand, Erin E; Stucker, Jaclyn C; Littleton, Ashley C; Aguilar, Alain J; Petschauer, Meredith A; Teel, Elizabeth F; Mihalik, Jason P

    2016-09-01

    There are limited nonlaboratory soccer head impact biomechanics data. This is surprising given soccer's global popularity. Epidemiological data suggest that female college soccer players are at a greater concussion injury risk than their male counterparts. Therefore, the purposes of our study were to quantify head impact frequency and magnitude during women's soccer practices and games in the National Collegiate Athletic Association and to characterize these data across event type, playing position, year on the team, and segment of game (first and second halves). Head impact biomechanics were collected from female college soccer players (n = 22; mean ± SD age = 19.1 ± 0.1 yr, height = 168.0 ± 3.5 cm, mass = 63.7 ± 6.0 kg). We employed a helmetless head impact measurement device (X2 Biosystems xPatch) before each competition and practice across a single season. Peak linear and rotational accelerations were categorized based on impact magnitude and subsequently analyzed using appropriate nonparametric analyses. Overall, women's college soccer players experience approximately seven impacts per 90 min of game play. The overwhelming majority (~90%) of all head impacts were categorized into our mildest linear acceleration impact classification (10g-20g). Interestingly, a higher percentage of practice impacts in the 20g-40g range compared with games (11% vs 7%) was observed. Head impact biomechanics studies have provided valuable insights into understanding collision sports and for informing evidence-based rule and policy changes. These have included changing the football kickoff, ice hockey body checking ages, and head-to-head hits in both sports. Given soccer's global popularity, and the growing public concern for the potential long-term neurological implications of collision and contact sports, studying soccer has the potential to impact many athletes and the sports medicine professionals caring for them.

  3. Device for radiotherapy

    International Nuclear Information System (INIS)

    Levinta, A.

    2002-01-01

    The invention refers to medicine, in particular to radiology. Summary of the invention consists in that the device for the radiotherapy includes a base a headrest, a mechanism for head fixation, means for placement of the formation element, the mechanism for head fixation representing a semicircle situated in horizontal position and fixed to the base with the possibility of displacement, in the centre of which it is installed a fixing arm, and the means for placement of the formation elements representing at least two semicircles, mounted in vertical position and fixed into supports with the possibility of mutual swiveling of each of them, between the headrest and the base being installed the neck support

  4. Reactor head shielding apparatus

    International Nuclear Information System (INIS)

    Schukei, G.E.; Roebelen, G.J.

    1992-01-01

    This patent describes a nuclear reactor head shielding apparatus for mounting on spaced reactor head lifting members radially inwardly of the head bolts. It comprises a frame of sections for mounting on the lifting members and extending around the top central area of the head, mounting means for so mounting the frame sections, including downwardly projecting members on the frame sections and complementary upwardly open recessed members for fastening to the lifting members for receiving the downwardly projecting members when the frame sections are lowered thereto with lead shielding supported thereby on means for hanging lead shielding on the frame to minimize radiation exposure or personnel working with the head bolts or in the vicinity thereof

  5. Giant magneto-resistance devices

    CERN Document Server

    Hirota, Eiichi; Inomata, Koichiro

    2002-01-01

    This book deals with the application of giant magneto-resistance (GMR) effects to electronic devices. It will appeal to engineers and graduate students in the fields of electronic devices and materials. The main subjects are magnetic sensors with high resolution and magnetic read heads with high sensitivity, required for hard-disk drives with recording densities of several gigabytes. Another important subject is novel magnetic random-access memories (MRAM) with non-volatile non-destructive and radiation-resistant characteristics. Other topics include future GMR devices based on bipolar spin transistors, spin field-effect transistors (FETs) and double-tunnel junctions.

  6. 33 CFR 159.75 - Overcurrent protection.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Overcurrent protection. 159.75...) POLLUTION MARINE SANITATION DEVICES Design, Construction, and Testing § 159.75 Overcurrent protection. Overcurrent protection must be provided within the unit to protect subcomponents of the device if the...

  7. Research of formation of deposits in technological devices and corrosion of contact devices from stainless steel

    Directory of Open Access Journals (Sweden)

    KATAMANOV Vladimir Leonidovich

    2017-11-01

    Full Text Available The paper shows that for majority of technological plants used to process hydrocarbon raw materials when operating a problem of formation of deposits in still-head pipes after the rectifying and stabilization columns, furnaces and other technology devices in oil processing is still of great importance. The structure of still-head deposits of furnace coils and rectifying columns has been studied by the example of small technological plant (STP of JSC Kondensat (Aksay, the Republic of Kazakhstan. It was determined that key components of these deposits are sulfides of iron and copper as well as elementary sulfur. It is shown that the surface of contact devices of STP – grids made of stainless steel of brand 12X18H10T, is substantially subject to corrosion. These samples are the structures which are still keeping geometry of initial grids, but lost their functional properties and characteristics. When mechanical influence is applied such samples easily transform into gray high-disperse powder. During operation period of STP various corrosion inhibitors and deemulgators (for example, TAL-25-13-R have been tested. At the same time practically all tested brands of corrosion inhibitors couldn't decrease corrosion of stainless steel and formation of firm deposits in still-head pipes of technological devices. The existing corrosion inhibitors create protection on the boundary of phases metallic surface – liquid, but they aren't efficient on the boundary of phases metallic surface – liquid – steam-gas phase (at the temperature of 150–250оC. The authors propose the mechanism of formation of these compounds based on result of corrosion of metal gauzes made of stainless steels brand X6CrNiTi18-10in the presence of sulphurous compounds.An active method of corrosion prevention is recommended to apply. The method is based on creation of nanodimensional anticorrosion coatings from binary compounds (such as titanium nitride or pure metals (Ni, Cr, Ti

  8. Digital protection in power plants. Electrical unit and line protection. Digital protection systems for NPP

    International Nuclear Information System (INIS)

    Kaczmarek, A.

    2000-01-01

    In this presentation author deals with the digital protection systems for nuclear power plants. The evolution of protection devices, protection concept for power plants, concept of functional redundancy, references for digital protection, benefits for the customer well as concept fault recorder are presented. (author)

  9. Protection of electronic circuits from overvoltages

    CERN Document Server

    Standler, Ronald B

    1989-01-01

    Practical rules and strategies designed to protect electronic systems from damage by transient overvoltages include symptoms and threats, remedies, protective devices and their applications, and validation of protective measures. 1989 edition.

  10. Photovoltaic device

    Energy Technology Data Exchange (ETDEWEB)

    Reese, Jason A; Keenihan, James R; Gaston, Ryan S; Kauffmann, Keith L; Langmaid, Joseph A; Lopez, Leonardo; Maak, Kevin D; Mills, Michael E; Ramesh, Narayan; Teli, Samar R

    2017-03-21

    The present invention is premised upon an improved photovoltaic device ("PV device"), more particularly to an improved photovoltaic device with a multilayered photovoltaic cell assembly and a body portion joined at an interface region and including an intermediate layer, at least one interconnecting structural member, relieving feature, unique component geometry, or any combination thereof.

  11. Photovoltaic device

    Science.gov (United States)

    Reese, Jason A.; Keenihan, James R.; Gaston, Ryan S.; Kauffmann, Keith L.; Langmaid, Joseph A.; Lopez, Leonardo C.; Maak, Kevin D.; Mills, Michael E.; Ramesh, Narayan; Teli, Samar R.

    2015-06-02

    The present invention is premised upon an improved photovoltaic device ("PV device"), more particularly to an improved photovoltaic device with a multilayered photovoltaic cell assembly and a body portion joined at an interface region and including an intermediate layer, at least one interconnecting structural member, relieving feature, unique component geometry, or any combination thereof.

  12. Photovoltaic device

    Science.gov (United States)

    Reese, Jason A.; Keenihan, James R.; Gaston, Ryan S.; Kauffmann, Keith L.; Langmaid, Joseph A.; Lopez, Leonardo C.; Maak, Kevin D.; Mills, Michael E.; Ramesh, Narayan; Teli, Samar R.

    2015-09-01

    The present invention is premised upon an improved photovoltaic device ("PV device"), more particularly to an improved photovoltaic device (10) with a multilayered photovoltaic cell assembly (100) and a body portion (200) joined at an interface region (410) and including an intermediate layer (500), at least one interconnecting structural member (1500), relieving feature (2500), unique component geometry, or any combination thereof.

  13. Lesion-Related Carotid Angioplasty and Stenting with Closed-Cell Design without Embolic Protection Devices in High-Risk Elderly Patients-Can This Concept Work Out? A Single Center Experience Focusing on Stent Design.

    Science.gov (United States)

    Hopf-Jensen, Silke; Marques, Leonardo; Preiß, Michael; Müller-Hülsbeck, Stefan

    2014-12-01

    To compare the performance differences of three carotid artery stents in high-risk elderly patients without embolic protection devices (EPDs) on the basis of stent design, procedure-related complications, conveniences in handling, in-stent restenosis, 30-day outcome, and long-term follow-up. A total of 101 symptomatic internal carotid stenoses of 94 patients were prospectively treated with stent-protected angioplasty to 94 patients. Three closed-cell stents, one of those being hybrid cell design, were chosen depending on vascular anatomy: curved vessel, lesion length > 1 cm: 64 Carotid Wallstent (Boston Scientific, Natick, MA); curved vessel, lesion length  1 cm: 16 Xact (Vascular Abbott, Santa Clara, CA). Comparisons of demographics, procedures, and outcomes were performed. The mean age of patients was 73.1 years (standard deviation [SD], ± 7.9; range, 58-87 years), 71% of the patients were older than 70 years and 20% were octogenarians. Male/female ratio was 3.1:1. About 13.9% (14/101) had contralateral internal carotid artery occlusion. Overall peri-interventional complication rate was 2.9% and 30-day mortality rate was 1%. During the long-term follow-up (34 months, range 1-59) no ipsilateral stroke was documented. Ten deaths (three after MI) were recognized. Two in-stent restenosis were detected (> 70% North American Symptomatic Carotid Endarterectomy Trial) during follow-up, one patient was detected with previous carotid endarterectomy. Especially, if individual anatomical variance is considered, lesion-related stent-protected carotid angioplasty with lesion-adapted closed-cell design is an effective, reliable, safe, and comprehensible treatment option in symptomatic patients. Even without EPDs, the rate of complications is low, when compared with symptomatic carotid artery stenosis described in the literature. In-stent restenosis seems to play no significant role in follow-up.

  14. Radiation beans characterization and implantation for study of lead equivalent individual protection device used in radiodiagnostic practices; Caracterizacao e implantacao de feixes de radiacao para estudo de dispositivos de protecao individual com equivalencia em chumbo utilizados em praticas de radiodiagnostico

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, Leslie Silva

    2004-07-01

    The protective shielding (IPC) must be used by occupationally exposed professionals, patients and volunteers, in order to optimize the doses who receive due to radiological practices. International and national norms establish the methodology to be adopted for determination of the IPC attenuation. In this work, the IPC had been submitted to X-rays beams with known characteristics, standardized for determination of their attenuation equivalent thickness by comparison to an experimental lead attenuation slope. This comparison technique allowed insurance estimative of the IPC attenuation equivalent thickness in mm of lead. Thus, it was possible to verify the conformity of the attenuation equivalent thickness determined experimentally and the value of the thickness indicated by the manufacturer. To carry out this work, it was necessary the implementation of experimental setups stated in the specifics norms, the study of the X-rays beams original features and the determination of combined additional filters, in order to allow the X-ray equipment used operates in compliance with Norm IEC 61331-1 IEC. The radiation quality selected is characterized by a 100 kV voltage and a 0.25 mm of copper overall filtration. The implementation of this radiation quality it was carried through of its first and second HVL (Half Value Layer). Thus, a methodology according to the international Norms has been implemented in the laboratory. The results of the present work provide suitable and useful information about radiation beams features related to the determination techniques of the attenuation properties. Once implemented the procedures for conformity evaluation of the protection devices, it will be possible to carry out specific quality control tests, which will be helpful to manufacturers, customers, as well as authorities in the radiological protection and health areas. (author)

  15. Femoral head avascular necrosis

    International Nuclear Information System (INIS)

    Chrysikopoulos, H.; Sartoris, D.J.; Resnick, D.L.; Ashburn, W.; Pretorius, T.

    1988-01-01

    MR imaging has been shown to be more sensitive and specific than planar scintigraphy for avascular necrosis (AVN) of the femoral head. However, experience with single photon emission CT (SPECT) is limited. The authors retrospectively compared 1.5-T MR imaging with SPECT in 14 patients with suspected femoral head AVN. Agreement between MR imaging and SPECT was present in 24 femurs, 14 normal and ten with AVN. MR imaging showed changes of AVN in the remaining four femoral heads. Of these, one was normal and the other three inconclusive for AVN by SPECT. The authors conclude that MR imaging is superior to SPECT for the evaluation of AVN of the hip

  16. Cranial computed tomography utilization in head trauma in a Southern Nigerian tertiary hospital

    Directory of Open Access Journals (Sweden)

    Ehimwenma Ogbeide

    2015-01-01

    Full Text Available Background: Computed tomography (CT is the imaging modality of choice in evaluating patients with acute head trauma. Objective: The objective of this study is to assess CT utilization in head trauma in University of Benin Teaching Hospital (UBTH with reference to sociodemographic characteristics and cause of injury. Materials and Methods: A retrospective study of patients who had CT scanning done for head trauma in the UBTH, from 2011 to 2013 was undertaken. Medical Records of patients with special emphasis on the patient′s demographic characteristics and detailed information about the cause of injury of the patients were obtained from the accident and emergency department of the hospital. Data were analyzed using SPSS version 17. Results: A total of 1387 patients with male: female ratio of 3.7:1 were studied. The mean age of the patients was 33.2 ± 18.8 years. Road traffic accidents (RTA were the predominant cause of injury among the patients accounting for 62.6% of the cases. Gunshot injury (GSI and patients struck by objects accounted for only 2.7% and 1.3% of the cases, respectively. The Glasgow coma score (GCS of the patients revealed that 42.0%, 26.1%, and 31.9% of patients had severe head injury, moderate injury, and mild injury, respectively. Conclusion: Road traffic accidents involving young adult males constituted the predominant cause of injury in patients that had brain CT in UBTH. There is an urgent need for improvement in the condition of roads and enforcement of the use of protective devices by road users to curb the epidemic of head injury resulting from RTAs.

  17. Computing camera heading: A study

    Science.gov (United States)

    Zhang, John Jiaxiang

    2000-08-01

    An accurate estimate of the motion of a camera is a crucial first step for the 3D reconstruction of sites, objects, and buildings from video. Solutions to the camera heading problem can be readily applied to many areas, such as robotic navigation, surgical operation, video special effects, multimedia, and lately even in internet commerce. From image sequences of a real world scene, the problem is to calculate the directions of the camera translations. The presence of rotations makes this problem very hard. This is because rotations and translations can have similar effects on the images, and are thus hard to tell apart. However, the visual angles between the projection rays of point pairs are unaffected by rotations, and their changes over time contain sufficient information to determine the direction of camera translation. We developed a new formulation of the visual angle disparity approach, first introduced by Tomasi, to the camera heading problem. Our new derivation makes theoretical analysis possible. Most notably, a theorem is obtained that locates all possible singularities of the residual function for the underlying optimization problem. This allows identifying all computation trouble spots beforehand, and to design reliable and accurate computational optimization methods. A bootstrap-jackknife resampling method simultaneously reduces complexity and tolerates outliers well. Experiments with image sequences show accurate results when compared with the true camera motion as measured with mechanical devices.

  18. Eye Protection in Kansas Schools.

    Science.gov (United States)

    Hay, Kenneth M.; And Others

    A law passed by a state legislature requires that students in industrial arts shops and science laboratories must wear eye protective devices. Explanatory material presents the text of the bill and guidelines for implementation, including--(1) types of eye hazards, (2) types of protective devices, (3) administrating eye safety equipment, (4)…

  19. Tritium removal and retention device

    International Nuclear Information System (INIS)

    Boyle, R.F.; Durigon, D.D.

    1980-01-01

    A device is provided for removing and retaining tritium from a gaseous medium, and also a method of manufacturing the device. The device, consists of an inner core of zirconium alloy, preferably Zircaloy-4, and an outer adherent layer of nickel which acts as a selective and protective window for passage of tritium. The tritium then reacts with or is absorbed by the zirconium alloy, and is retained until such time as it is desirable to remove it during reprocessing. (auth)

  20. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... you! Do you have a personal story about radiology? Share your patient story here Images × Image Gallery ... Pregnancy Head and Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to ...

  1. Exploding head syndrome.

    Science.gov (United States)

    Sharpless, Brian A

    2014-12-01

    Exploding head syndrome is characterized by the perception of abrupt, loud noises when going to sleep or waking up. They are usually painless, but associated with fear and distress. In spite of the fact that its characteristic symptomatology was first described approximately 150 y ago, exploding head syndrome has received relatively little empirical and clinical attention. Therefore, a comprehensive review of the scientific literature using Medline, PsycINFO, Google Scholar, and PubMed was undertaken. After first discussing the history, prevalence, and associated features, the available polysomnography data and five main etiological theories for exploding head syndrome are summarized. None of these theories has yet reached dominance in the field. Next, the various methods used to assess and treat exploding head syndrome are discussed, as well as the limited outcome data. Finally, recommendations for future measure construction, treatment options, and differential diagnosis are provided. Copyright © 2014 Elsevier Ltd. All rights reserved.

  2. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... medically necessary because of potential risk to the baby. This risk is, however, minimal with head CT ... intravenous contrast indicate mothers should not breastfeed their babies for 24-48 hours after contrast medium is ...

  3. Early Head Start Evaluation

    Data.gov (United States)

    U.S. Department of Health & Human Services — Longitudinal information from an evaluation where children were randomly assigned to Early Head Start or community services as usual;direct assessments and...

  4. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... top of page Additional Information and Resources RTAnswers.org Radiation Therapy for Brain Tumors Radiation Therapy for ... Tomography (CT) - Head Sponsored by Please note RadiologyInfo.org is not a medical facility. Please contact your ...

  5. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... of the Head? Computed tomography, more commonly known as a CT or CAT scan, is a diagnostic ... white on the x-ray; soft tissue, such as organs like the heart or liver, shows up ...

  6. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... microphone. top of page How does the procedure work? In many ways CT scanning works very much ... head CT scanning. Manufacturers of intravenous contrast indicate mothers should not breastfeed their babies for 24-48 ...

  7. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... rays). top of page What are some common uses of the procedure? CT scanning of the head ... is done because a potential abnormality needs further evaluation with additional views or a special imaging technique. ...

  8. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... rays). top of page What are some common uses of the procedure? CT scanning of the head ... community, you can search the ACR-accredited facilities database . This website does not provide cost information. The ...

  9. Head Start Impact Study

    Data.gov (United States)

    U.S. Department of Health & Human Services — Nationally representative, longitudinal information from an evaluation where children were randomly assigned to Head Start or community services as usual;direct...

  10. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Stroke Brain Tumors Computer Tomography (CT) Safety During Pregnancy Head and Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Computed Tomography (CT) - ...

  11. TCGA head Neck

    Science.gov (United States)

    Investigators with The Cancer Genome Atlas (TCGA) Research Network have discovered genomic differences – with potentially important clinical implications – in head and neck cancers caused by infection with the human papillomavirus (HPV).

  12. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... your doctor to evaluate your face, sinuses, and skull or to plan radiation therapy for brain cancer. ... typically used to detect: bleeding, brain injury and skull fractures in patients with head injuries. bleeding caused ...

  13. The exploding head syndrome.

    Science.gov (United States)

    Green, M W

    2001-06-01

    This article reviews the features of an uncommon malady termed "the exploding head syndrome." Sufferers describe terrorizing attacks of a painless explosion within their head. Attacks tend to occur at the onset of sleep. The etiology of attacks is unknown, although they are considered to be benign. Treatment with clomipramine has been suggested, although most sufferers require only reassurance that the spells are benign in nature.

  14. GPK heading machine

    Energy Technology Data Exchange (ETDEWEB)

    Krmasek, J.; Novosad, K.

    1981-01-01

    This article evaluates performance tests of the Soviet made GPK heading machine carried out in 4 coal mines in Czechoslovakia (Ostrava-Karvina region and Kladno mines). GPK works in coal seams and rocks with compression strength of 40 to 50 MPa. Dimensions of the tunnel are height 1.8 to 3.8 m and width 2.6 to 4.7 m, tunnel gradient plus to minus 10 degrees. GPK weighs 16 t, its conical shaped cutting head equipped with RKS-1 cutting tools is driven by an electric motor with 55 kW capacity. Undercarriage of the GPK, gathering-arm loader, hydraulic system, electric system and dust supression system (water spraying or pneumatic section) are characterized. Specifications of GPK heading machines are compared with PK-3r and F8 heading machines. Reliability, number of failures, dust level, noise, productivity depending on compression strength of rocks, heading rate in coal and in rocks, energy consumption, performance in inclined tunnels, and cutting tool wear are evaluated. Tests show that GPK can be used to drive tunnels in coal with rock constituting up to 50% of the tunnel crosscut, as long as rock compression strength does not exceed 50 MPa. In rocks characterized by higher compression strength cutting tool wear sharply increases. GPK is characterized by higher productivity than that of the PK-3r heading machine. Among the weak points of the GPK are: unsatisfactory reliability and excessive wear of its elements. (4 refs.) (In Czech)

  15. Information booklet on personal protective equipment: eye and face protection

    International Nuclear Information System (INIS)

    1992-01-01

    In all work places where hazards of various kinds are present and the same cannot be totally controlled by engineering methods, suitable personal protective equipment (PPE) shall be used. There are several types of eye and face protection devices available in the market and it is important that employees use the proper type for the particular job. The main classes of eye and face protection devices required for the industrial operations are as follows: (a) eye protection devices which includes: (i) safety goggles (ii) safety spectacles (iii) safety clipons and eye and face protection devices which are (i) eye shield, (ii) face shield, (iii) wire mesh screen guard. Guide lines for selecting appropriate ear and face protection equipment for nuclear installations are given. (M.K.V.). 4 annexures, 1 appendix

  16. Head-up and head-down displays integration in automobiles

    Science.gov (United States)

    Betancur, J. Alejandro; Osorio-Gómez, Gilberto; Agudelo, J. David

    2014-06-01

    In automotive industry, the dashboard has been ergonomically developed in order to keep the driver focused on the horizon while driving, but the possibility to access external electronic devices constraints the driver to turn away his face, generating dangerous situations in spite of the short periods of time. Therefore, this work explores the integration of Head-Up Displays and Head-Down Displays in automobiles, proposing configurations that give to drivers the facility to driving focused. In this way, some of the main ergonomic comments about those configurations are proposed; and also, some technical comments regarding the implemented arrangements are given.

  17. Advances and trends of head-up and head-down display systems in automobiles

    Science.gov (United States)

    Betancur, J. Alejandro; Osorio-Gomez, Gilberto; Agudelo, J. David

    2014-06-01

    Currently, in the automotive industry the interaction between drivers and Augmented Reality (AR) systems is a subject of analysis, especially the identification of advantages and risks that this kind of interaction represents. Consequently, this paper attempts to put in evidence the potential applications of Head-Up (Display (HUD) and Head-Down Display (HDD) systems in automotive vehicles, showing applications and trends under study. In general, automotive advances related to AR devices suggest the partial integration of the HUD and HDD in automobiles; however, the right way to do it is still a moot point.

  18. Sealing device

    Science.gov (United States)

    Garcia-Crespo, Andres Jose

    2013-12-10

    A sealing device for sealing a gap between a dovetail of a bucket assembly and a rotor wheel is disclosed. The sealing device includes a cover plate configured to cover the gap and a retention member protruding from the cover plate and configured to engage the dovetail. The sealing device provides a seal against the gap when the bucket assemply is subjected to a centrifugal force.

  19. Microfluidic Device

    Science.gov (United States)

    Tai, Yu-Chong (Inventor); Zheng, Siyang (Inventor); Lin, Jeffrey Chun-Hui (Inventor); Kasdan, Harvey L. (Inventor)

    2017-01-01

    Described herein are particular embodiments relating to a microfluidic device that may be utilized for cell sensing, counting, and/or sorting. Particular aspects relate to a microfabricated device that is capable of differentiating single cell types from dense cell populations. One particular embodiment relates a device and methods of using the same for sensing, counting, and/or sorting leukocytes from whole, undiluted blood samples.

  20. Gauging device

    International Nuclear Information System (INIS)

    Qurnell, F.D.; Patterson, C.B.

    1979-01-01

    A gauge supporting device for measuring say a square tube comprises a pair of rods or guides in tension between a pair of end members, the end members being spaced apart by a compression member or members. The tensioned guides provide planes of reference for measuring devices moved therealong on a carriage. The device is especially useful for making on site dimensional measurements of components, such as irradiated and therefore radioactive components, that cannot readily be transported to an inspection laboratory. (UK)

  1. A pre-Hispanic head.

    Directory of Open Access Journals (Sweden)

    Raffaella Bianucci

    Full Text Available This report on a male head revealed biologic rhythms, as gleaned from hydrogen isotope ratios in hair, consistent with a South-American origin and Atomic Mass Spectrometry radiocarbon dating (AMS compatible with the last pre-Hispanic period (1418-1491 AD, 95.4% probability. Biopsies showed exceptionally well-preserved tissues. The hair contained high levels of toxic elements (lead, arsenic and mercury incompatible with life. There was no evidence for lead deposition in bone consistent with post-mortem accumulation of this toxic element in the hair. We propose that the high content of metals in hair was the result of metabolic activity of bacteria leading to metal complexation in extra cellular polymeric substances (EPS. This is a recognized protective mechanism for bacteria that thrive in toxic environments. This mechanism may account for the tissues preservation and gives a hint at soil composition where the head was presumably buried. Our results have implications for forensic toxicology which has, hitherto, relied on hair analyses as one means to reconstruct pre-mortem metabolism and for detecting toxic elements accumulated during life. Our finding also has implications for other archaeological specimens where similar circumstances may distort the results of toxicological studies.

  2. A pre-Hispanic head.

    Science.gov (United States)

    Bianucci, Raffaella; Jeziorska, Maria; Lallo, Rudy; Mattutino, Grazia; Massimelli, Massimo; Phillips, Genevieve; Appenzeller, Otto

    2008-04-30

    This report on a male head revealed biologic rhythms, as gleaned from hydrogen isotope ratios in hair, consistent with a South-American origin and Atomic Mass Spectrometry radiocarbon dating (AMS) compatible with the last pre-Hispanic period (1418-1491 AD, 95.4% probability). Biopsies showed exceptionally well-preserved tissues. The hair contained high levels of toxic elements (lead, arsenic and mercury) incompatible with life. There was no evidence for lead deposition in bone consistent with post-mortem accumulation of this toxic element in the hair. We propose that the high content of metals in hair was the result of metabolic activity of bacteria leading to metal complexation in extra cellular polymeric substances (EPS). This is a recognized protective mechanism for bacteria that thrive in toxic environments. This mechanism may account for the tissues preservation and gives a hint at soil composition where the head was presumably buried. Our results have implications for forensic toxicology which has, hitherto, relied on hair analyses as one means to reconstruct pre-mortem metabolism and for detecting toxic elements accumulated during life. Our finding also has implications for other archaeological specimens where similar circumstances may distort the results of toxicological studies.

  3. Nutrition in Patients with Head Trauma

    Directory of Open Access Journals (Sweden)

    Burcu Totur

    2013-01-01

    Full Text Available The need of energy increases by 40% in patients with a head trauma, when compared to people who are living a normal life. This ratio reaches to 200% in some cases. It is important to give a nutrition support which can satisfy the energy need resulted from the hypermetabolic and hypercatabolic states and that is enough to help to fix the immunologic state and achieve a better result in healing the injury. When oral nutrition is not possible in the patient with a head trauma, their energy need is satisfied through enteral and parenteral nutrition. Though parenteral nutrition had held an important role in feeding patients with head trauma, enteral nutrition is applied much more widely today. Enteral and parenteral nutrition both has their own advantages and disadvantages. In the clinical and laboratory studies that had been held, it was found that enteral nutrition improved the systemic immunity, decreased the incidence of the major infectious complications, decreased the metabolic response to trauma, protected the intestinal mucosa, and protected the ecologic balance of the microflora. In this article, it is investigated through the importance of the feeding in patients with a head trauma and reasons to chose enteral nutrition

  4. Safety of persons protected by the Government Protection Bureau

    Directory of Open Access Journals (Sweden)

    Wojciech Lis

    2015-12-01

    Full Text Available The state is the organizational structure, which unites the whole nation by providing optimal conditions for the functioning and development. One of the conditions for the basic functions of the state is efficient administration headed by a person with the role of management. They not only hold the highest position, but also represent the authority of the state. For this reason, they need special protection. Each attack undermines the authority of the administration and trust in the state institutions. For the protection of persons performing managerial functions in the state corresponds to the Government Protection Bureau that providing them protection at the same time protect the state.

  5. Fast reactor recharging device

    International Nuclear Information System (INIS)

    Artemiev, L.N.; Kurilkin, V.V.

    1979-01-01

    Disclosure is made of a device for recharging a fast-neutron reactor, intended for the transfer of fuel assemblies and rods of the control and safety system, having profiled heads to be gripped on the outside. The device comprises storage drums whose compartments for rods of the control and safety system are identical to compartments for fuel assemblies. In order to store and transport rods of the control and safety system from the storage drums to the recharging mechanism provision is made for sleeve-type holders. When placed in such a holder, the dimensions of a rod of the control and safety system are equal to those of a fuel assembly. To join a holder to a rod of the control and safety system, on the open end of each holder there is mounted a collet, whereas on the surface of each rod of the control and safety system, close to its head, there is provided an encircling groove to interact with the collet. The grip of the recharging mechanism is provided with a stop interacting with the collet in order to open the latter and withdraw the safety and control system rod from its holder

  6. Magnetic Resonance Imaging (MRI) -- Head

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - Head Magnetic resonance imaging (MRI) of the head uses a powerful ... the Head? What is MRI of the Head? Magnetic resonance imaging (MRI) is a noninvasive medical test that ...

  7. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - Head Magnetic resonance imaging (MRI) of the head uses a powerful ... the Head? What is MRI of the Head? Magnetic resonance imaging (MRI) is a noninvasive medical test that ...

  8. Head, Neck, and Oral Cancer

    Medline Plus

    Full Text Available ... find out more. Oral, Head and Neck Pathology Oral, Head and Neck Pathology Close to 49,750 Americans will be diagnosed ... find out more. Oral, Head and Neck Pathology Oral, Head and Neck Pathology Close to 49,750 Americans will be diagnosed ...

  9. Head, Neck, and Oral Cancer

    Science.gov (United States)

    ... find out more. Oral, Head and Neck Pathology Oral, Head and Neck Pathology Close to 49,750 Americans will be diagnosed ... find out more. Oral, Head and Neck Pathology Oral, Head and Neck Pathology Close to 49,750 Americans will be diagnosed ...

  10. Magnetic-bubble devices

    International Nuclear Information System (INIS)

    Fairholme, R.J.

    1978-01-01

    Magnetic bubbles were first described only ten years ago when research workers were discussing orthoferrites containing μm diameter bubbles. However, problems of material fabrication limit crystals to a few mm across which severely curtailed device development. Since then materials have changed and rare-earth-iron garnet films can be grown up 3 inches in diameter with bubble diameters down to sizes below 1 μm. The first commercial products have device capacities in the range 64 000 to 100 000 bits with bubble diameters between 4 and 6 μm. Chip capacities of 1 Mbit are presently under development in the laboratory, as are new techniques to use submicrometre bubbles. The operation and fabrication of a bubble device is described using the serial loop devices currently being manufactured at Plessey as models. Chip organization is one important variable which directly affects the access time. A range of access times and capacities is available which offers a wide range of market opportunities, ranging from consumer products to fixed head disc replacements. some of the application areas are described. (author)

  11. Real-Time Head Pose Estimation on Mobile Platforms

    Directory of Open Access Journals (Sweden)

    Jianfeng Ren

    2010-06-01

    Full Text Available Many computer vision applications such as augmented reality require head pose estimation. As far as the real-time implementation of head pose estimation on relatively resource limited mobile platforms is concerned, it is required to satisfy real-time constraints while maintaining reasonable head pose estimation accuracy. The introduced head pose estimation approach in this paper is an attempt to meet this objective. The approach consists of the following components: Viola-Jones face detection, color-based face tracking using an online calibration procedure, and head pose estimation using Hu moment features and Fisher linear discriminant. Experimental results running on an actual mobile device are reported exhibiting both the real- time and accuracy aspects of the developed approach.

  12. Skin Cancer of the Head and Neck

    OpenAIRE

    Ouyang, Yun-Hsuan

    2010-01-01

    The majority of skin cancers of the head and neck are nonmelanoma skin cancers (NMSC). Basal cell carcinoma and squamous cell carcinoma are the most frequent types of NMSC. Malignant melanoma is an aggressive neoplasm of skin, and the ideal adjuvant therapy has not yet been found, although various options for treatment of skin cancer are available to the patient and physician, allowing high cure rate and excellent functional and cosmetic outcomes. Sunscreen protection and early evaluation of ...

  13. Shivering heat production and core cooling during head-in and head-out immersion in 17 degrees C water.

    Science.gov (United States)

    Pretorius, Thea; Cahill, Farrell; Kocay, Sheila; Giesbrecht, Gordon G

    2008-05-01

    Many cold-water scenarios cause the head to be partially or fully immersed (e.g., ship wreck survival, scuba diving, cold-water adventure swim racing, cold-water drowning, etc.). However, the specific effects of head cold exposure are minimally understood. This study isolated the effect of whole-head submersion in cold water on surface heat loss and body core cooling when the protective shivering mechanism was intact. Eight healthy men were studied in 17 degrees C water under four conditions: the body was either insulated or exposed, with the head either out of the water or completely submersed under the water within each insulated/exposed subcondition. Submersion of the head (7% of the body surface area) in the body-exposed condition increased total heat loss by 11% (P < 0.05). After 45 min, head-submersion increased core cooling by 343% in the body-insulated subcondition (head-out: 0.13 +/- 0.2 degree C, head-in: 0.47 +/- 0.3 degree C; P < 0.05) and by 56% in the body-exposed subcondition (head-out: 0.40 +/- 0.3 degree C and head-in: 0.73 +/- 0.6 degree C; P < 0.05). In both body-exposed and body-insulated subconditions, head submersion increased the rate of core cooling disproportionally more than the relative increase in total heat loss. This exaggerated core-cooling effect is consistent with a head cooling induced reduction of the thermal core, which could be stimulated by cooling of thermosensitive and/or trigeminal receptors in the scalp, neck, and face. These cooling effects of head submersion are not prevented by shivering heat production.

  14. Fusion devices

    International Nuclear Information System (INIS)

    Fowler, T.K.

    1977-01-01

    Three types of thermonuclear fusion devices currently under development are reviewed for an electric utilities management audience. Overall design features of laser fusion, tokamak, and magnetic mirror type reactors are described and illustrated. Thrusts and trends in current research on these devices that promise to improve performance are briefly reviewed. Twenty photographs and drawings are included

  15. BRAKE DEVICE

    Science.gov (United States)

    O'Donnell, T.J.

    1959-03-10

    A brake device is described for utilization in connection with a control rod. The device comprises a pair of parallelogram link mechanisms, a control rod moveable rectilinearly therebetween in opposite directions, and shoes resiliently supported by the mechanism for frictional engagement with the control rod.

  16. Perspectives about family meals from single-headed and dual-headed households: a qualitative analysis.

    Science.gov (United States)

    Berge, Jerica M; Hoppmann, Caroline; Hanson, Carrie; Neumark-Sztainer, Dianne

    2013-12-01

    Cross-sectional and longitudinal research has shown that family meals are protective for adolescent healthful eating behaviors. However, little is known about what parents think of these findings and whether parents from single- vs dual-headed households have differing perspectives about the findings. In addition, parents' perspectives regarding barriers to applying the findings on family meals in their own homes and suggestions for more widespread adoption of the findings are unknown. The current study aimed to identify single- and dual-headed household parents' perspectives regarding the research findings on family meals, barriers to applying the findings in their own homes, and suggestions for helping families have more family meals. The current qualitative study included 59 parents who participated in substudy of two linked multilevel studies-EAT 2010 (Eating and Activity in Teens) and Families and Eating and Activity in Teens (F-EAT). Parents (91.5% female) were racially/ethnically and socioeconomically diverse. Data were analyzed using a grounded theory approach. Results from the current study suggest that parents from both single- and dual-headed households have similar perspectives regarding why family meals are protective for healthful eating habits for adolescents (eg, provides structure/routine, opportunities for communication, connection), but provide similar and different reasons for barriers to family meals (eg, single-headed=cost vs dual-headed=lack of creativity) and ideas and suggestions for how to increase the frequency of family meals (eg, single-headed=give fewer options vs dual-headed=include children in the meal preparation). Findings can help inform public health intervention researchers and providers who work with adolescents and their families to understand how to approach discussions regarding reasons for having family meals, barriers to carrying out family meals, and ways to increase family meals depending on family structure. Copyright

  17. PLASMA DEVICE

    Science.gov (United States)

    Gow, J.D.; Wilcox, J.M.

    1961-12-26

    A device is designed for producing and confining highenergy plasma from which neutrons are generated in copious quantities. A rotating sheath of electrons is established in a radial electric field and axial magnetic field produced within the device. The electron sheath serves as a strong ionizing medium to gas introdueed thereto and also functions as an extremely effective heating mechanism to the resulting plasma. In addition, improved confinement of the plasma is obtained by ring magnetic mirror fields produced at the ends of the device. Such ring mirror fields are defined by the magnetic field lines at the ends of the device diverging radially outward from the axis of the device and thereafter converging at spatial annular surfaces disposed concentrically thereabout. (AFC)

  18. Fast-response protection from high currents

    International Nuclear Information System (INIS)

    Novikov, A.A.

    1989-01-01

    Protection devices for power electronic equipment from shorting current are described. The device is shunted using spark gaps with minimal possible number of spark gaps to protect it. High fast-response (<100 ns) and operation voltage wide range (6-100 kV) are attained using Arkadiev-Marx generator-base trigger devices and air-core pulse transformer

  19. Assessment of the Effectiveness of Combat Eyewear Protection Against Blast Overpressure.

    Science.gov (United States)

    Sundaramurthy, A; Skotak, M; Alay, E; Unnikrishnan, G; Mao, H; Duan, X; Williams, S T; Harding, T H; Chandra, N; Reifman, J

    2018-07-01

    It is unclear whether combat eyewear used by U. S. Service members is protective against blast overpressures (BOPs) caused by explosive devices. Here, we investigated the mechanisms by which BOP bypasses eyewear and increases eye surface pressure. We performed experiments and developed three-dimensional (3D) finite element (FE) models of a head form (HF) equipped with an advanced combat helmet (ACH) and with no eyewear, spectacles, or goggles in a shock tube at three BOPs and five head orientations relative to the blast wave. Overall, we observed good agreement between experimental and computational results, with average discrepancies in impulse and peak-pressure values of less than 15% over 90 comparisons. In the absence of eyewear and depending on the head orientation, we identified three mechanisms that contributed to pressure loading on the eyes. Eyewear was most effective at 0 deg orientation, with pressure attenuation ranging from 50 (spectacles) to 80% (goggles) of the peak pressures observed in the no-eyewear configuration. Spectacles and goggles were considerably less effective when we rotated the HF in the counter-clockwise direction around the superior-inferior axis of the head. Surprisingly, at certain orientations, spectacles yielded higher maximum pressures (80%) and goggles yielded larger impulses (150%) than those observed without eyewear. The findings from this study will aid in the design of eyewear that provides better protection against BOP.

  20. Radiation protection measuring device SSM-1

    International Nuclear Information System (INIS)

    Anon.

    1988-01-01

    Product information from the producer on a universal measuring instrument for alpha, beta and gamma radiation designed for stationary and field use by military, police and fire brigades. 4 figs. (qui)

  1. The study and development of magnetic recording heads. A thin film integrated magnetic head

    International Nuclear Information System (INIS)

    Lazzari, Jean-Pierre

    1970-01-01

    A new integrated magnetic head is described. The head was made by vacuum deposition using a mask. A magnetically coupled multilayer construction led to high performance. The results obtained indicate that the device functions equally well, for reading and writing. A set of calculations was developed which could simulate and optimize the behavior of the recording head. The results obtained with the writing were in good agreement with those obtained from experiments and quite different from results which have been several times previously published. In addition a new method was developed for measuring high fields in confined spaces; a 1000 A diameter probe was used in conjunction with a low angle diffraction procedure. The measurements give results which are very different from those obtained by current theories based on the magnetic potentials at the surface. (author) [fr

  2. Head first Ajax

    CERN Document Server

    Riordan, Rebecca M

    2008-01-01

    Ajax is no longer an experimental approach to website development, but the key to building browser-based applications that form the cornerstone of Web 2.0. Head First Ajax gives you an up-to-date perspective that lets you see exactly what you can do -- and has been done -- with Ajax. With it, you get a highly practical, in-depth, and mature view of what is now a mature development approach. Using the unique and highly effective visual format that has turned Head First titles into runaway bestsellers, this book offers a big picture overview to introduce Ajax, and then explores the use of ind

  3. Head First Statistics

    CERN Document Server

    Griffiths, Dawn

    2009-01-01

    Wouldn't it be great if there were a statistics book that made histograms, probability distributions, and chi square analysis more enjoyable than going to the dentist? Head First Statistics brings this typically dry subject to life, teaching you everything you want and need to know about statistics through engaging, interactive, and thought-provoking material, full of puzzles, stories, quizzes, visual aids, and real-world examples. Whether you're a student, a professional, or just curious about statistical analysis, Head First's brain-friendly formula helps you get a firm grasp of statistics

  4. Multi-sector thermophysiological head simulator for headgear research

    OpenAIRE

    Martínez Guillamón, Natividad

    2016-01-01

    [EN] Predicting thermal comfort perceived during wearing protective clothing is important especially for the head as it is one of the most sensitive body parts to heat. Since helmets typically induce an additional thermal insulation that impairs the heat dissipation from the head, a special attention should be drawn to a heat strain leading to a decrease of the cognitive performance and to adverse health effects. Thermal manikins allow systematic analysis of the heat and mass transfer prop...

  5. 21 CFR 820.130 - Device packaging.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Device packaging. 820.130 Section 820.130 Food and... QUALITY SYSTEM REGULATION Labeling and Packaging Control § 820.130 Device packaging. Each manufacturer shall ensure that device packaging and shipping containers are designed and constructed to protect the...

  6. Anti-malware software and medical devices.

    Science.gov (United States)

    2010-10-01

    Just as much as healthcare information systems, medical devices need protection against cybersecurity threats. Anti-malware software can help safeguard the devices in your facility-but it has limitations and even risks. Find out what steps you can take to manage anti-malware applications in your devices.

  7. Sealing devices

    International Nuclear Information System (INIS)

    Coulson, R.A.

    1980-01-01

    A sealing device for minimising the leakage of toxic or radioactive contaminated environments through a biological shield along an opening through which a flexible component moves that penetrates the shield. The sealing device comprises an outer tubular member which extends over a length not less than the maximum longitudinal movement of the component along the opening. An inner sealing block is located intermediate the length of the component by connectors and is positioned in the bore of the outer tubular member to slide in the bore and effect a seal over the entire longitudinal movement of the component. The cross-section of the device may be circular and the block may be of polytetrafluoroethylene or of nylon impregnated with molybdenum or may be metallic. A number of the sealing devices may be combined into an assembly for a plurality of adjacent longitudinally movable components, each adapted to sustain a tensile load, providing the various drives of a master-slave manipulator. (author)

  8. Silva as the Head

    DEFF Research Database (Denmark)

    Svabo, Connie

    2015-01-01

    The head of the performance design programme is substituted by a sister's academy delegate. this performance situation formed part of a week of semesterstart where the students and professors visited Sister's Academy, Malmø. I participated in the Sister's Academy as visiting researcher and here i...

  9. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head ...

  10. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... are present in the paranasal sinuses. plan radiation therapy for cancer of the brain or other tissues. guide the ... RTAnswers.org Radiation Therapy for Brain Tumors Radiation Therapy for Head and Neck Cancer Others American Stroke Association National Stroke Association top ...

  11. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media Radiation Dose in X-Ray and CT Exams Blood Clots CT Perfusion of the Head CT Angiography ( ...

  12. The Twente humanoid head

    NARCIS (Netherlands)

    Reilink, Rob; Visser, L.C.; Bennik, J.; Carloni, Raffaella; Brouwer, Dannis Michel; Stramigioli, Stefano

    2009-01-01

    This video shows the results of the project on the mechatronic development of the Twente humanoid head. The mechanical structure consists of a neck with four degrees of freedom (DOFs) and two eyes (a stereo pair system) which tilt on a common axis and rotate sideways freely providing a three more

  13. Ferroelectric devices

    CERN Document Server

    Uchino, Kenji

    2009-01-01

    Updating its bestselling predecessor, Ferroelectric Devices, Second Edition assesses the last decade of developments-and setbacks-in the commercialization of ferroelectricity. Field pioneer and esteemed author Uchino provides insight into why this relatively nascent and interdisciplinary process has failed so far without a systematic accumulation of fundamental knowledge regarding materials and device development.Filling the informational void, this collection of information reviews state-of-the-art research and development trends reflecting nano and optical technologies, environmental regulat

  14. Head injury in children

    International Nuclear Information System (INIS)

    Sugiura, Makoto; Mori, Nobuhiko; Yokosuka, Reiko; Yamamoto, Masaaki; Imanaga, Hirohisa

    1981-01-01

    Findings of computerized tomography (CT) in 183 cases of head injury in children were investigated with special reference to CT findings of mild head injury. As was expected, CT findings of mild head injury fell within the normal range, in almost all cases. However, abnormal findings were noticed in 4 out of 34 cases (12%) in acute stage and 7 out of 76 cases (9%) in chronic stage. They were 3 cases of localized low density area in acute stage and 6 cases of mild cerebral atrophy in chronic stage, etc. There were some cases of mild head injury in which CT findings were normal while EEG examination revealed abnormality. Also in some cases, x-ray study demonstrated linear skull fracture which CT failed to show. These conventional techniques could be still remained as useful adjunct aid in diagnosis of head injury. CT findings of cases of cerebral contusion in their acute stage were divided as follows; normal, low density, small ventricle and ventricular and/or cisternal hemorrhage, frequency of incidence being 38, 17, 22, 11% respectively. These findings were invariably converted to cerebral atrophy from 10 days to 2 months after the impacts. In the cases with intracranial hematoma revealed by CT, only 32% of them showed clinical signs of Araki's type IV in their acute stage and 63% of them showed no neurological defects, that is Araki's type I and II. A case of extreme diffuse cerebral atrophy which followed acute subdural hematoma caused by tear of bridging veins without cortical contusion was presented. (author)

  15. 49 CFR 178.337-10 - Accident damage protection.

    Science.gov (United States)

    2010-10-01

    ... failure of the sacrificial device must leave the protected lading protection device and its attachment to the cargo tank wall intact and capable of retaining product. [Order 59-B, 30 FR 581, Jan. 16, 1965...

  16. Optical fiber head for providing lateral viewing

    Science.gov (United States)

    Everett, Matthew J.; Colston, Billy W.; James, Dale L.; Brown, Steve; Da Silva, Luiz

    2002-01-01

    The head of an optical fiber comprising the sensing probe of an optical heterodyne sensing device includes a planar surface that intersects the perpendicular to axial centerline of the fiber at a polishing angle .theta.. The planar surface is coated with a reflective material so that light traveling axially through the fiber is reflected transverse to the fiber's axial centerline, and is emitted laterally through the side of the fiber. Alternatively, the planar surface can be left uncoated. The polishing angle .theta. must be no greater than 39.degree. or must be at least 51.degree.. The emitted light is reflected from adjacent biological tissue, collected by the head, and then processed to provide real-time images of the tissue. The method for forming the planar surface includes shearing the end of the optical fiber and applying the reflective material before removing the buffer that circumscribes the cladding and the core.

  17. Head and Neck Cancer Treatment

    Science.gov (United States)

    ... Professions Site Index A-Z Head and Neck Cancer Treatment Head and neck cancer overview What are my ... and neck cancer. For updated information on new cancer treatments that are available, you should discuss these issues ...

  18. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... for Brain Tumors Radiation Therapy for Head and Neck Cancer Others : American Stroke Association National Stroke Association ... MRA) Magnetic Resonance, Functional (fMRI) - Brain Head and Neck Cancer Treatment Brain Tumor Treatment Magnetic Resonance Imaging ( ...

  19. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... are the limitations of MRI of the Head? What is MRI of the Head? Magnetic resonance imaging ( ... brain) in routine clinical practice. top of page What are some common uses of the procedure? MR ...

  20. Head, Neck, and Oral Cancer

    Medline Plus

    Full Text Available ... and Neck Pathology Oral, Head and Neck Pathology Close to 49,750 Americans will be diagnosed with ... and Neck Pathology Oral, Head and Neck Pathology Close to 49,750 Americans will be diagnosed with ...

  1. Head Lice: Prevention and Control

    Science.gov (United States)

    ... and General Public. Contact Us Parasites Home Prevention & Control Language: English (US) Español (Spanish) Recommend on Facebook ... that can be taken to help prevent and control the spread of head lice: Avoid head-to- ...

  2. BIOMECHANICS OF HEAD INJURY IN OLYMPIC TAEKWONDO AND BOXING

    Science.gov (United States)

    Fife, G.P.; Pieter, W.

    2013-01-01

    Objective The purpose was to examine differences between taekwondo kicks and boxing punches in resultant linear head acceleration (RLA), head injury criterion (HIC15), peak head velocity, and peak foot and fist velocities. Data from two existing publications on boxing punches and taekwondo kicks were compared. Methods For taekwondo head impacts a Hybrid II Crash Dummy (Hybrid II) head was instrumented with a tri-axial accelerometer mounted inside the Hybrid II head. The Hybrid II was fixed to a height-adjustable frame and fitted with a protective taekwondo helmet. For boxing testing, a Hybrid III Crash Dummy head was instrumented with an array of tri-axial accelerometers mounted at the head centre of gravity. Results Differences in RLA between the roundhouse kick (130.11±51.67 g) and hook punch (71.23±32.19 g, d = 1.39) and in HIC15 (clench axe kick: 162.63±104.10; uppercut: 24.10±12.54, d = 2.29) were observed. Conclusions Taekwondo kicks demonstrated significantly larger magnitudes than boxing punches for both RLA and HIC. PMID:24744497

  3. Magnetic Force Microscopy Observation of Perpendicular Recording Head Remanence

    Science.gov (United States)

    Dilekrojanavuti, P.; Saengkaew, K.; Cheowanish, I.; Damrongsak, B.

    2017-09-01

    In this work, magnetic force microscopy (MFM) was utilized to observe the magnetic write head remanence, which is the remaining out-of-plane magnetic field on magnetic write heads after a write current is turned off. This remnant field can write unwanted tracks or erase written tracks on a magnetic media. The write head remanence can also occur from device and slider fabrication, either by applying current to the write coil during the inspection or biasing the external magnetic field to magnetic recording heads. This remanence can attract magnetic nanoparticles, which is suspended in cleaning water or surrounding air, and cause device contamination. MFM images were used to examine locations of the remnant field on the surface of magnetic recording heads. Experimental results revealed that the remanence occurred mostly on the shield and is dependent on the initial direction of magnetic moments. In addition, we demonstrated a potential use of MFM imaging to investigate effects of different etching gases on the head remanence.

  4. Preventive Long-Term Effects of a Topical Film-Forming Medical Device with Ultra-High UV Protection Filters and DNA Repair Enzyme in Xeroderma Pigmentosum: A Retrospective Study of Eight Cases

    Directory of Open Access Journals (Sweden)

    Sandra Giustini

    2014-09-01

    Full Text Available Skin cancer is common in xeroderma pigmentosum (XP due to a DNA repair mechanisms genetic defect. Ultraviolet (UV exposure is the main cause of increased incidence of actinic keratosis (AK, basal cell carcinoma (BCC and squamous cell carcinoma (SCC observed in XP subjects. Photoprotection is therefore a mandatory strategy in order to reduce skin damage. A topical DNA repair enzyme has been shown to slow down the development of skin lesions in XP. However, there are no data regarding the effects of photoprotection combined with DNA repair strategies in this clinical setting. A film-forming medical device containing the DNA repair enzyme photolyase and very high-protection UV filters (Eryfotona AK-NMSC, Ery is currently available. We report retrospective data regarding the use of Ery in 8 patients (5 women, 3 men with a diagnosis of XP treated for at least 12 consecutive months, comparing the rate of new skin lesions (AK, BCC and SCC during active treatment with Ery and during 12 months just before the use of the product. New AK, BCC and SCC mean lesion numbers during the 1-year Ery treatment were 5, 3 and 0, respectively in comparison with 14, 6.8 and 3 lesions, respectively during the 1-year pre-treatment period. Ery use was associated with a 65% reduction in appearance of new AK lesions and with 56 and 100% reductions in the incidence of new BCC and SCC lesions, respectively. These data suggest that topical use of photoprotection and DNA repair enzyme could help lower skin cancer lesions in XP. Control prospective trials are advisable in this clinical setting.

  5. Development and testing of a flexible ballistic neck protection

    NARCIS (Netherlands)

    Roebroeks, G.H.J.J.; Rensink, P.

    2016-01-01

    Sufficient ballistic protection of the neck area would significantly reduce the vulnerability of an infantry soldier. So far this protection is offered by extensions on the ballistic vest or combat helmet. However, the requirements for head agility and the various body to head positions combined

  6. Phosphorus-32: practical radiation protection

    International Nuclear Information System (INIS)

    Ballance, P.E.; Morgan, J.

    1987-01-01

    This monograph offers practical advice to Radiation Protection Advisors, Radiation Protection Supervisors and Research Supervisors, together with research workers, particularly those in the field of molecular biological research. The subject is dealt with under the following headings: physical properties, radiation and measurement methods, radiation units, phosphorus metabolism and health risks, protection standards and practical radiation protection, administrative arrangements, accidents, decontamination, emergency procedures, a basic written system for radiochemical work, with specialised recommendations for 32 P, and guidance notes of accident situations involving 32 P. (U.K.)

  7. 49 CFR 393.24 - Requirements for head lamps, auxiliary driving lamps and front fog lamps.

    Science.gov (United States)

    2010-10-01

    ... Devices, and Electrical Wiring § 393.24 Requirements for head lamps, auxiliary driving lamps and front fog lamps. (a) Headlamps. Every bus, truck and truck tractor shall be equipped with headlamps as required by...

  8. Mounted Combat System Crew Shock Loading: Head and Neck Injury Potential Evaluation

    National Research Council Canada - National Science Library

    LaFiandra, Michael E; Zywiol, Harry

    2007-01-01

    ...) ride motion simulator (RMS) was used to simulate the effects of gun firing shock on a Hybrid III instrumented anthropometric test device capable of measuring neck force and torque and head acceleration...

  9. Pressure suppression device

    International Nuclear Information System (INIS)

    Mizumachi, Wataru; Fukuda, Akira; Kitaguchi, Hidemi; Shimizu, Toshiaki.

    1976-01-01

    Object: To relieve and absorb impact wave vibrations caused by steam and non-condensed gases releasing into the pressure suppression chamber at the time of an accident. Structure: The reactor container is filled with inert gases. A safety valve attached main steam pipe is provided to permit the excessive steam to escape, the valve being communicated with the pressure suppression chamber through an exhaust pipe. In the pressure suppression chamber, a doughnut-like cylindrical outer wall is filled at its bottom with pool water to condense the high temperature vapor released through the exhaust pipe. A head portion of a vent tube which leads the exhaust pipe is positioned at the top, and a down comer and an exhaust vent tube are locked by means of steady rests. At the bottom is mounted a pressure adsorber device which adsorbs a pressure from the pool water. (Kamimura, M.)

  10. Guide device

    International Nuclear Information System (INIS)

    Brammer, C.M. Jr.

    1977-01-01

    Disclosed is a fuel handling guide tube centering device for use in nuclear reactors during fuel assembly handling operations. The device comprises an outer ring secured to the flange of a nuclear reactor pressure vessel, a rotatable table rotatably coupled to the outer ring, and a plurality of openings through the table. Truncated locating cones are positioned in each of the openings in the table, and the locating cones center the guide tube during fuel handling operations. The openings in the table are located such that each fuel assembly in the nuclear core may be aligned with one of the openings by a suitable rotation of the table. The locating cones thereby provide alignment between the fuel handling mechanism located in the guide tube and the individual fuel assemblies of the cone. The need for a device to provide alignment is especially critical for floating nuclear power plants, where wave motion may exist during fuel handling operations. 5 claims, 4 figures

  11. MRI in head trauma

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Jin Kyo [Shin Wha Hospital, Seoul (Korea, Republic of)

    1986-02-15

    In the diagnosis of head injury, Magnetic Resonance Imaging (MRI), like CT, is an effective method of distinguishing between intracerebral and extracerebral lesions. In our experience of MRI, early hematomas are almost isointense by Saturation Recovery (SR) method, so these must be performed with Spin Echo (SE) method for better visualization of hematomas. Isodense subdural hematomas, which is a diagnostic dilemma on CT images, are clearly seen on MRI. Delayed hematomas or residual parenchymal lesions are better demonstrated on MRI than on CT. Direct cornal, sagittal images and multiplanar facility of MRI provides excellent visualization of the the location and shape of extracerebral collection of hematoma. For the screening of head traumas, SE method is a technique of choice because of its excellent sensitivity within limited time.

  12. Where is Russia heading?

    Directory of Open Access Journals (Sweden)

    Natalija Pliskevič

    1999-10-01

    Full Text Available The author examines the proceedings from the collection Where is Russia Heading? (= Куда идёт Россия?, published between 1994 and 1998 in connection with the international symposium held under this name each year in Moscow. The symposia and their proceeding, involving leading Russian and foreign experts, were significant in that they encompassed a wide range of themes – social, economic, political, legislative, cultural and other transformations that have been occurring in Russia during the past decades. The author, however, limits her review to contributions dealing with ethno-political and socio-cultural transformations in Russia. She concludes that the question – “Where is Russia heading?” – still remains open to answers.

  13. MRI in head trauma

    International Nuclear Information System (INIS)

    Hong, Jin Kyo

    1986-01-01

    In the diagnosis of head injury, Magnetic Resonance Imaging (MRI), like CT, is an effective method of distinguishing between intracerebral and extracerebral lesions. In our experience of MRI, early hematomas are almost isointense by Saturation Recovery (SR) method, so these must be performed with Spin Echo (SE) method for better visualization of hematomas. Isodense subdural hematomas, which is a diagnostic dilemma on CT images, are clearly seen on MRI. Delayed hematomas or residual parenchymal lesions are better demonstrated on MRI than on CT. Direct cornal, sagittal images and multiplanar facility of MRI provides excellent visualization of the the location and shape of extracerebral collection of hematoma. For the screening of head traumas, SE method is a technique of choice because of its excellent sensitivity within limited time.

  14. "Head versus heart"

    Directory of Open Access Journals (Sweden)

    Paul Rozin

    2007-08-01

    Full Text Available Most American respondents give ``irrational,'' magical responses in a variety of situations that exemplify the sympathetic magical laws of similarity and contagion. In most of these cases, respondents are aware that their responses (usually rejections, as of fudge crafted to look like dog feces, or a food touched by a sterilized, dead cockroach are not ``scientifically'' justified, but they are willing to avow them. We interpret this, in some sense, as ``heart over head.'' We report in this study that American adults and undergraduates are substantially less likely to acknowledge magical effects when the judgments involve money (amount willing to pay to avoid an ``unpleasant'' magical contact than they are when using preference or rating measures. We conclude that in ``head-heart'' conflicts of this type, money tips the balance towards the former, or, in other words, that money makes the mind less magical.

  15. [The exploding head syndrome].

    Science.gov (United States)

    Bongers, K M; ter Bruggen, J P; Franke, C L

    1991-04-06

    The case is reported of a 47-year old female suffering from the exploding head syndrome. This syndrome consists of a sudden awakening due to a loud noise shortly after falling asleep, sometimes accompanied by a flash of light. The patient is anxious and experiences palpitations and excessive sweating. Most patients are more than fifty years of age. Further investigations do not reveal any abnormality. The pathogenesis is unknown, and no therapy other than reassurance is necessary.

  16. Where are we heading

    International Nuclear Information System (INIS)

    Noto, L.A.

    1996-01-01

    The present paper deals with different aspects connected to the global petroleum industry by discussing the way of heading. The aspects cover themes like new frontiers, new relationships, sanctions, global climate change, new alliances and new technology. New frontiers and relationships concern domestic policy affecting the industry, and sanctions are discussed in connection with trade. The author discusses the industry's participation in the global environmental policy and new alliances to provide greater opportunity for developing new technology

  17. "Head versus heart"

    OpenAIRE

    Paul Rozin; Heidi Grant; Stephanie Weinberg; Scott Parker

    2007-01-01

    Most American respondents give ``irrational,'' magical responses in a variety of situations that exemplify the sympathetic magical laws of similarity and contagion. In most of these cases, respondents are aware that their responses (usually rejections, as of fudge crafted to look like dog feces, or a food touched by a sterilized, dead cockroach) are not ``scientifically'' justified, but they are willing to avow them. We interpret this, in some sense, as ``heart over head.'' We report in this ...

  18. Head segmentation in vertebrates

    OpenAIRE

    Kuratani, Shigeru; Schilling, Thomas

    2008-01-01

    Classic theories of vertebrate head segmentation clearly exemplify the idealistic nature of comparative embryology prior to the 20th century. Comparative embryology aimed at recognizing the basic, primary structure that is shared by all vertebrates, either as an archetype or an ancestral developmental pattern. Modern evolutionary developmental (Evo-Devo) studies are also based on comparison, and therefore have a tendency to reduce complex embryonic anatomy into overly simplified patterns. Her...

  19. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... as a CT or CAT scan, is a diagnostic medical test that, like traditional x-rays, produces ... medical device of any kind, unlike MRI. A diagnosis determined by CT scanning may eliminate the need ...

  20. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple ... can be performed if you have an implanted medical device of any kind, unlike MRI. A diagnosis ...

  1. The state of head injury biomechanics: past, present, and future part 2: physical experimentation.

    Science.gov (United States)

    Goldsmith, Werner; Monson, Kenneth L

    2005-01-01

    This presentation is the continuation of the article published in Critical Reviews of Biomedical Engineering, 29(5-6), 2001. That issue contained topics dealing with components and geometry of the human head, classification of head injuries, some early experimental studies, and tolerance considerations. It then dealt with head motion and load characterization, investigations during the period from 1939 to 1966, injury causation and early modeling efforts, the 1966 Head Injury Conference and its sequels, mechanical properties of solid tissues, fluid characterization, and early investigation of the mechanical properties of cranial materials. It continued with a description of the systematic investigations of solid cranial components and structural properties since 1966, fetal cranial properties, analytical head modeling, and numerical solutions of head injury. The paper concluded with experimental dynamic loading of human living and cadaver heads, dynamic loading of surrogate heads, and head injury mechanics. This portion of the paper describes physical head injury experimentation involving animals, primarily primates, human cadavers, volunteers, and inanimate physical models. In order to address the entire domain of head injury biomechanics in the two-part survey, it was intended that this information be supplemented by discussions of head injury tolerance and criteria, automotive and sports safety considerations, and the design of protective equipment, but Professor Goldsmith passed away before these sections could be completed. It is nevertheless anticipated that this attenuated installment will provide, in conjunction with the first part of the survey, a valuable resource for students and practitioners of head injury biomechanics.

  2. RF and dc desensitized electroexplosive device

    Science.gov (United States)

    Krainiak, John W.; Speaks, Paul D.; Cornett, Michael S.

    1989-07-01

    This patent application relates to electroexplosive devices (EEDs) such as detonators, blasting caps and squibs, in particular to a method and device for desensitizing EEDs to electromagnetic radiation and electrostatic charges with the added ability to desensitize the device to essentially dc currents. An insensitive electroexplosive device to electrically ignite explosive is disclosed. This device is inherently immune to radio frequency (RF) radiation, and also provides protection against dc or very low frequency RF induced by arcing. A central feature is use of zeners and capacitors to form a reactively balanced bridge circuit. When constructed in semiconductor form, as described in this application, the device is capable of incorporation in small caliber ordnance.

  3. Audiovisual Head Orientation Estimation with Particle Filtering in Multisensor Scenarios

    Directory of Open Access Journals (Sweden)

    Javier Hernando

    2007-07-01

    Full Text Available This article presents a multimodal approach to head pose estimation of individuals in environments equipped with multiple cameras and microphones, such as SmartRooms or automatic video conferencing. Determining the individuals head orientation is the basis for many forms of more sophisticated interactions between humans and technical devices and can also be used for automatic sensor selection (camera, microphone in communications or video surveillance systems. The use of particle filters as a unified framework for the estimation of the head orientation for both monomodal and multimodal cases is proposed. In video, we estimate head orientation from color information by exploiting spatial redundancy among cameras. Audio information is processed to estimate the direction of the voice produced by a speaker making use of the directivity characteristics of the head radiation pattern. Furthermore, two different particle filter multimodal information fusion schemes for combining the audio and video streams are analyzed in terms of accuracy and robustness. In the first one, fusion is performed at a decision level by combining each monomodal head pose estimation, while the second one uses a joint estimation system combining information at data level. Experimental results conducted over the CLEAR 2006 evaluation database are reported and the comparison of the proposed multimodal head pose estimation algorithms with the reference monomodal approaches proves the effectiveness of the proposed approach.

  4. Medical Devices

    NARCIS (Netherlands)

    Verkerke, Gijsbertus Jacob; Mahieu, H.F.; Geertsema, A.A.; Hermann, I.F.; van Horn, J.R.; Hummel, J. Marjan; van Loon, J.P.; Mihaylov, D.; van der Plaats, A.; Schraffordt Koops, H.; Schutte, H.K.; Veth, R.P.H.; de Vries, M.P.; Rakhorst, G.; Shi, Donglu

    2004-01-01

    The development of new medical devices is a very time-consuming and costly process. Besides the time between the initial idea and the time that manufacturing and testing of prototypes takes place, the time needed for the development of production facilities, production of test series, marketing,

  5. Assistive Devices

    Science.gov (United States)

    If you have a disability or injury, you may use a number of assistive devices. These are tools, products or types of equipment that help you perform tasks and activities. They may help you move around, see, communicate, eat, or get ...

  6. Detection device

    Science.gov (United States)

    Smith, J.E.

    1981-02-27

    The present invention is directed to a detection device comprising: (1) an entrance chamber; (2) a central chamber; and (3) an exit chamber. The central chamber includes an ionizing gas, anode, and means for connecting the anode with an external power supply and pulse counter.

  7. Cooling device in thermonuclear device

    International Nuclear Information System (INIS)

    Honda, Tsutomu.

    1988-01-01

    Purpose: To prevent loss of cooling effect over the entire torus structure directly after accidental toubles in a cooling device of a thermonuclear device. Constitution: Coolant recycling means of a cooling device comprises two systems, which are alternately connected with in-flow pipeways and exit pipeways of adjacent modules. The modules are cooled by way of the in-flow pipeways and the exist pipeways connected to the respective modules by means of the coolant recycling means corresponding to the respective modules. So long as one of the coolant recycling means is kept operative, since every one other modules of the torus structure is still kept cooled, the heat generated from the module put therebetween, for which the coolant recycling is interrupted, is removed by means of heat conduction or radiation from the module for which the cooling is kept continued. No back-up emergency cooling system is required and it can provide high economic reliability. (Kamimura, M.)

  8. Selecting the Protective Ear Plugs

    OpenAIRE

    Manouchehr Omidvari

    1999-01-01

    Exposure to noise is a one of the common problems in any industrial places. Many solutions have been introduced to overcome the deleterious effects of noise pollution maintaining and repairing systems in the equipments, environmental control and hearing conservation systems are some of these solutions that could be mentioned. "nThere are various types of Hearing protection devices and each one is useful under special circumstances. Commonly, different Hearing protection devices have a particu...

  9. Reactor power measuring device

    International Nuclear Information System (INIS)

    Izumi, Mikio; Sano, Yuji; Seki, Eiji; Yoshida, Toshifumi; Ito, Toshiaki.

    1993-01-01

    The present invention provides a self-powered long detector having a sensitivity over the entire length of a reactor core as an entire control rod withdrawal range of a BWR type reactor, and a reactor power measuring device using a gamma ray thermometer which scarcely causes sensitivity degradation. That is, a hollow protection pipe is disposed passing through the reactor core from the outside of a reactor pressure vessel. The self-powered long detectors and the gamma ray thermometers are inserted and installed in the protection pipe. An average reactor power in an axial direction of the reactor relative to a certain position in the horizontal cross section of the reactor core is determined based on the power of the self-powered long detector over the entire length of the reactor core. Since the response of the self-powered detector relative to a local power change is rapid, the output is used as an input signal to a safety protection device of the reactor core. Further, a gamma ray thermometer secured in the reactor and having scarce sensitivity degradation is used instead of an incore travelling neutron monitor used for relative calibration of an existent neutron monitor secured in the reactor. (I.S.)

  10. Registered manufacturers of renewable energy devices

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    Registered manufacturers of renewable energy devices in India are listed. The list is arranged under the headings : solar water heating system, solar cooker, solar still and water pumping wind mill. In all 38 manufacturers are listed. The list gives the postal address, name of the contact person and phone number of each manufacturer. (M.G.B.)

  11. Thermal effects of dorsal head immersion in cold water on nonshivering humans.

    Science.gov (United States)

    Giesbrecht, Gordon G; Lockhart, Tamara L; Bristow, Gerald K; Steinman, Allan M

    2005-11-01

    Personal floatation devices maintain either a semirecumbent flotation posture with the head and upper chest out of the water or a horizontal flotation posture with the dorsal head and whole body immersed. The contribution of dorsal head and upper chest immersion to core cooling in cold water was isolated when the confounding effect of shivering heat production was inhibited with meperidine (Demerol, 2.5 mg/kg). Six male volunteers were immersed four times for up to 60 min, or until esophageal temperature = 34 degrees C. An insulated hoodless dry suit or two different personal floatation devices were used to create four conditions: 1) body insulated, head out; 2) body insulated, dorsal head immersed; 3) body exposed, head (and upper chest) out; and 4) body exposed, dorsal head (and upper chest) immersed. When the body was insulated, dorsal head immersion did not affect core cooling rate (1.1 degrees C/h) compared with head-out conditions (0.7 degrees C/h). When the body was exposed, however, the rate of core cooling increased by 40% from 3.6 degrees C/h with the head out to 5.0 degrees C/h with the dorsal head and upper chest immersed (P immersed (approximately 10%). The exaggerated core cooling during dorsal head immersion (40% increase) may result from the extra heat loss affecting a smaller thermal core due to intense thermal stimulation of the body and head and resultant peripheral vasoconstriction. Dorsal head and upper chest immersion in cold water increases the rate of core cooling and decreases potential survival time.

  12. Safety work with MRI devices in medicine

    International Nuclear Information System (INIS)

    Zivkovic, D.; Hrnjak, M.

    1999-01-01

    This paper gives the basis of biological effects of physical factors which could affect personnel working on MRI devices and patients, and corresponding protection measures. Medical personnel working with MRI devices and patients could be exposed to static magnetic field, time varying fields and radiofrequency radiation, danger from electric current and chemical matters, and there is a high risk from moving metal objects which could wound the persons near-by. The protection from static magnetic field could be ensured by increasing the distance from the source. If MRI device is put in Faradays cage it could be corresponding protection of radiofrequency radiation. (author)

  13. Head injuries in snowboarders compared with head injuries in skiers. A prospective analysis of 1076 patients from 1994 to 1999 in Niigata, Japan.

    Science.gov (United States)

    Fukuda, O; Takaba, M; Saito, T; Endo, S

    2001-01-01

    We investigated snowboarding-related head injury cases and skiing-related head injury cases during five ski seasons at one resort area. There were 634 snowboarding-related head injuries and 442 skiing-related head injuries. The number of snowboarding head injuries increased rapidly over the study period. More male snowboarders than female snowboarders suffered head injuries. For both snowboarders and skiers, head injuries frequently occurred on the easy and middle slopes. Falls were the most frequent causes of injury in both groups. Jumping was a more frequent cause of injury in the snowboarders (30%) than in the skiers (2.5%). Injury to the occipital region predominated in the snowboarders as compared with the skiers. There were 49 organic lesions in 37 snowboarders and 46 organic lesions in 33 skiers. Subdural hematoma was frequent in the snowboarding head injury group, and fracture was frequent in the skiing head injury group compared with the snowboarding group (not significant). Subdural hematoma was likely to be caused by a fall rather than by a collision, and bone fracture was likely to be caused by a collision rather than by a fall. Four snowboarders and one skier died as a result of their head injuries. Our data suggest that snowboarding head injuries may be prevented by protection of the occipital region and refraining from jumping by beginners.

  14. Health hazards of uranium dust from radioactive battlefields of the Balkan conflicts, Eastern Afghanistan and Iraq after the Gulf wars. Lessons for civil protection in the terrorist scenario of radiological dispersion devices

    International Nuclear Information System (INIS)

    Durakovic, A.; Klimaschewski, F.

    2007-01-01

    Complete text of publication follows. Purpose: The purpose of this study is to identify key health hazards of uranium dust from the radioactive battlefields (Balkan, Middle East and Eastern Afghanistan conflicts) to draw lessons for civil protection in the terrorist scenario of radiological dispersion devices (RDD). Gulf War I (GW I) in 1991 resulted in 350 metric tons of depleted uranium (DU) deposited in the environment and 3 to 6 million grams of DU aerosol dust particles released into the atmosphere, by the most conservative estimates. Its possible legacy (Gulf War disease) continues after the military conflicts (Operation Enduring Freedom, OEF, in Afghanistan and Gulf War II in Iraq). The symptoms of the multiorgan incapacitating progressive disease have been as numerous as their names, including incapacitating fatigue, musculoskeletal and joint pains, headaches, neuropsychiatric disorders, affects changes, confusion, visual problems, changes of gait, loss of memory, lympadenopathies, respiratory impairment, impotence, and urinary tract morphological and functional alterations. The disease is still a matter of controversy regarding etiology and pathogenesis of the syndrome commonly named Gulf War disease. It was underestimated and subsequently evolved in its clinical description through recognition of progressive symptomatology. Methods: UMRC's studies of the human contamination with uranium isotopes were conducted with the exposed subjects of Jalalabad, Spin Gar, Tora Bora, and Kabul areas in Afghanistan after OEF as well as Samawah, Baghdad and Basrah in Iraq after GW II. The urine samples of the subjects were analysed by the plasma mass spectrometry. The analytical methodology involved pre-concentration of the uranium using co-precipitation and/or evaporation, oxidation of organic matter, purification of uranium with ion exchange chromatography, and mass spectrometry with a double focusing Thermo-Elemental Plasma54 multi-collector ICP-MS equipped with a

  15. Treating Head Lice

    Science.gov (United States)

    ... Blood & Biologics Articulos en Espanol Protect Yourself Health Fraud Consumer Information by Audience For Seniors For Women ... feeds Follow FDA on Twitter Follow FDA on Facebook View FDA videos on YouTube View FDA photos ...

  16. 46 CFR 111.51-3 - Protection of vital equipment.

    Science.gov (United States)

    2010-10-01

    ...-GENERAL REQUIREMENTS Coordination of Overcurrent Protective Devices § 111.51-3 Protection of vital equipment. (a) The coordination of overcurrent protective devices must be demonstrated for all potential... 46 Shipping 4 2010-10-01 2010-10-01 false Protection of vital equipment. 111.51-3 Section 111.51-3...

  17. Kinematics of the AM-50 heading machine cutting head

    Energy Technology Data Exchange (ETDEWEB)

    Sikora, W; Bak, K; Klich, R [Politechnika Slaska, Gliwice (Poland). Instytut Mechanizacji Gornictwa

    1987-01-01

    Analyzes motion of the cutter head of the AM-50 heading machine. Two types of head motion are comparatively evaluated: planar motion and spatial motion. The spatial motion consists of the head rotational motion and horizontal or vertical feed motion, while planar motion consists of rotational motion and vertical feed motion. Equations that describe head motion under conditions of cutter vertical or horizontal feed motion are derived. The angle between the cutting speed direction and working speed direction is defined. On the basis of these formulae variations of cutting speed depending on the cutting tool position on a cutter head are calculated. Calculations made for 2 extreme cutting tools show that the cutting speed ranges from 1,205 m/s to 3,512 m/s. 4 refs.

  18. Thin film device applications

    CERN Document Server

    Kaur, Inderjeet

    1983-01-01

    Two-dimensional materials created ab initio by the process of condensation of atoms, molecules, or ions, called thin films, have unique properties significantly different from the corresponding bulk materials as a result of their physical dimensions, geometry, nonequilibrium microstructure, and metallurgy. Further, these characteristic features of thin films can be drasti­ cally modified and tailored to obtain the desired and required physical characteristics. These features form the basis of development of a host of extraordinary active and passive thin film device applications in the last two decades. On the one extreme, these applications are in the submicron dimensions in such areas as very large scale integration (VLSI), Josephson junction quantum interference devices, magnetic bubbles, and integrated optics. On the other extreme, large-area thin films are being used as selective coatings for solar thermal conversion, solar cells for photovoltaic conver­ sion, and protection and passivating layers. Ind...

  19. Head First Web Design

    CERN Document Server

    Watrall, Ethan

    2008-01-01

    Want to know how to make your pages look beautiful, communicate your message effectively, guide visitors through your website with ease, and get everything approved by the accessibility and usability police at the same time? Head First Web Design is your ticket to mastering all of these complex topics, and understanding what's really going on in the world of web design. Whether you're building a personal blog or a corporate website, there's a lot more to web design than div's and CSS selectors, but what do you really need to know? With this book, you'll learn the secrets of designing effecti

  20. Head first C#

    CERN Document Server

    Stellman, Andrew

    2008-01-01

    Head First C# is a complete learning experience for object-oriented programming, C#, and the Visual Studio IDE. Built for your brain, this book covers C# 3.0 and Visual Studio 2008, and teaches everything from language fundamentals to advanced topics including garbage collection, extension methods, and double-buffered animation. You'll also master C#'s hottest and newest syntax, LINQ, for querying SQL databases, .NET collections, and XML documents. By the time you're through, you'll be a proficient C# programmer, designing and coding large-scale applications. Every few chapters you will come

  1. Head first C#

    CERN Document Server

    Stellman, Andrew

    2010-01-01

    You want to learn C# programming, but you're not sure you want to suffer through another tedious technical book. You're in luck: Head First C# introduces this language in a fun, visual way. You'll quickly learn everything from creating your first program to learning sophisticated coding skills with C# 4.0, Visual Studio 2010 and .NET 4, while avoiding common errors that frustrate many students. The second edition offers several hands-on labs along the way to help you build and test programs using skills you've learned up to that point. In the final lab, you'll put everything together. From o

  2. Head First Python

    CERN Document Server

    Barry, Paul

    2010-01-01

    Ever wished you could learn Python from a book? Head First Python is a complete learning experience for Python that helps you learn the language through a unique method that goes beyond syntax and how-to manuals, helping you understand how to be a great Python programmer. You'll quickly learn the language's fundamentals, then move onto persistence, exception handling, web development, SQLite, data wrangling, and Google App Engine. You'll also learn how to write mobile apps for Android, all thanks to the power that Python gives you. We think your time is too valuable to waste struggling with

  3. Thermonuclear device

    International Nuclear Information System (INIS)

    Tezuka, Masaru.

    1993-01-01

    Protrusions and recesses are formed to a vacuum vessel and toroidal magnetic coils, and they are engaged. Since the vacuum vessel is generally supported firmly by a rack or the like by support legs, the toroidal magnetic field coils can be certainly supported against tumbling force. Then, there can be attained strong supports for the toroidal magnetic field coils, in addition to support by wedges on the side of inboard and support by share panels on the side of outboard, capable of withstanding great electromagnetic forces which may occur in large-scaled next-generation devices. That is, toroidal magnetic field coils excellent from a view point of deformation and stress can be obtained, to provide a thermonuclear device of higher reliability. (N.H.)

  4. Thermonuclear device

    International Nuclear Information System (INIS)

    Oosaki, Osamu; Masuda, Kenju.

    1980-01-01

    Purpose: To provide excellent electric properties and high reliability in a thermonuclear device by improving a current collecting board connected to a coil device. Constitution: A current collecting board element perforated with an opening for enserting a connecting terminal is sized to be inserted into a plating tank, and is surface treated in the plating tank. Only the current collecting board element preferably surface treated is picked up. A plurality of such current collecting board elements are connected and welded to form a large current collecting board. In this manner, the current collecting board having several m 2 to several ten order m 2 in area can be obtained as preferably surface treated at the connecting terminal hole. The current collecting board element can be determined in shape with the existing facility without increasing the size of a surface treating tank. (Kamimura, M.)

  5. Thermonuclear device

    International Nuclear Information System (INIS)

    Yagi, Yasuomi; Takahashi, Ken; Hashimoto, Hiroshi.

    1984-01-01

    Purpose: To improve the plasma confining performances by bringing the irregular magnetic fields nearly to zero and decreasing the absolute value of the irregular magnetic fields at every positions. Constitution: The winding direction of a plurality of coil elements, for instance, double pan cake coils of toroidal coils in a torus type or mirror type thermonuclear device are reversed to each other in their laminating direction, whereby the irregular magnetic fields due to the coil-stepped portions in each toroidal coils are brought nearly to zero. This enables to bring the average irregular magnetic fields as a whole in the thermonuclear device nearly to zero, as well as, decrease the absolute value of the irregular magnetic fields in each positions. Thus, the plasma confining performances can be improved. (Moriyama, K.)

  6. Reactor vessel head permanent shield

    International Nuclear Information System (INIS)

    Hankinson, M.F.; Leduc, R.J.; Richard, J.W.; Malandra, L.J.

    1989-01-01

    A nuclear reactor is described comprising: a nuclear reactor pressure vessel closure head; control rod drive mechanisms (CRDMs) disposed within the closure head so as to project vertically above the closure head; cooling air baffle means surrounding the control rod drive mechanisms for defining cooling air paths relative to the control rod drive mechanisms; means defined within the periphery of the closure head for accommodating fastening means for securing the closure head to its associated pressure vessel; lifting lugs fixedly secured to the closure head for facilitating lifting and lowering movements of the closure head relative to the pressure vessel; lift rods respectively operatively associated with the plurality of lifting lugs for transmitting load forces, developed during the lifting and lowering movements of the closure head, to the lifting lugs; upstanding radiation shield means interposed between the cooling air baffle means and the periphery of the enclosure head of shielding maintenance personnel operatively working upon the closure head fastening means from the effects of radiation which may emanate from the control rod drive mechanisms and the cooling air baffle means; and connecting systems respectively associated with each one of the lifting lugs and each one of the lifting rods for connecting each one of the lifting rods to a respective one of each one of the lifting lugs, and for simultaneously connecting a lower end portion of the upstanding radiation shield means to each one of the respective lifting lugs

  7. "Distinvar" device

    CERN Multimedia

    CERN PhotoLab

    1965-01-01

    The alignment of one of the accelerator magnets being checked by the AR Division survey group. A "distinvar" device, invented by the group, using calibrated invar wires stretched between the fixed survey pillar (on the left) and a fixed point on the magnet. In two days it is thus possible to measure the alignment of the 100 magnets with an accuracy better than 1/10.

  8. Latching device

    Science.gov (United States)

    Ulrich, G. W. (Inventor)

    1975-01-01

    A latching device is suited for use in establishing a substantially motionless connection between a stationary receiver and a movable latching mechanism. The latching mechanism includes a pivotally supported restraining hook continuously urged into a capturing relationship with the receiver, characterized by a spring-biased pawl having a plurality of aligned teeth. The teeth are seated in the surface of the throat of the hook and positionable into restraining engagement with a rigid restraining shoulder projected from the receiver.

  9. Whistleblower Protection

    Science.gov (United States)

    The Whistleblower Protection Enhancement Act of 2012 (WPA) and the Whistleblower Protection Act of 1989 Enhanced by the Act of 2012 provides protection rights for Federal employees against retaliation for whistleblowing activities.

  10. Secure and Fair Cluster Head Selection Protocol for Enhancing Security in Mobile Ad Hoc Networks

    Directory of Open Access Journals (Sweden)

    B. Paramasivan

    2014-01-01

    Full Text Available Mobile ad hoc networks (MANETs are wireless networks consisting of number of autonomous mobile devices temporarily interconnected into a network by wireless media. MANETs become one of the most prevalent areas of research in the recent years. Resource limitations, energy efficiency, scalability, and security are the great challenging issues in MANETs. Due to its deployment nature, MANETs are more vulnerable to malicious attack. The secure routing protocols perform very basic security related functions which are not sufficient to protect the network. In this paper, a secure and fair cluster head selection protocol (SFCP is proposed which integrates security factors into the clustering approach for achieving attacker identification and classification. Byzantine agreement based cooperative technique is used for attacker identification and classification to make the network more attack resistant. SFCP used to solve this issue by making the nodes that are totally surrounded by malicious neighbors adjust dynamically their belief and disbelief thresholds. The proposed protocol selects the secure and energy efficient cluster head which acts as a local detector without imposing overhead to the clustering performance. SFCP is simulated in network simulator 2 and compared with two protocols including AODV and CBRP.

  11. Secure and fair cluster head selection protocol for enhancing security in mobile ad hoc networks.

    Science.gov (United States)

    Paramasivan, B; Kaliappan, M

    2014-01-01

    Mobile ad hoc networks (MANETs) are wireless networks consisting of number of autonomous mobile devices temporarily interconnected into a network by wireless media. MANETs become one of the most prevalent areas of research in the recent years. Resource limitations, energy efficiency, scalability, and security are the great challenging issues in MANETs. Due to its deployment nature, MANETs are more vulnerable to malicious attack. The secure routing protocols perform very basic security related functions which are not sufficient to protect the network. In this paper, a secure and fair cluster head selection protocol (SFCP) is proposed which integrates security factors into the clustering approach for achieving attacker identification and classification. Byzantine agreement based cooperative technique is used for attacker identification and classification to make the network more attack resistant. SFCP used to solve this issue by making the nodes that are totally surrounded by malicious neighbors adjust dynamically their belief and disbelief thresholds. The proposed protocol selects the secure and energy efficient cluster head which acts as a local detector without imposing overhead to the clustering performance. SFCP is simulated in network simulator 2 and compared with two protocols including AODV and CBRP.

  12. Sheep head frame validation for CT and MRI studies

    Directory of Open Access Journals (Sweden)

    marco trovatelli

    2017-05-01

    Full Text Available Abstract   Introductions Aim of EDEN 2020 project’s Milestone 5 is the development of a steerable catheter for CED system in glioblastoma therapy. The VET group is involved in realization and validation of the proper animal model. Materials and methods In this part of the study two fresh sheep’s head from the local slaughter were used. The heads were located into an ad hoc Frame system based on anatomical measures and CT images, producted by Renishaw plc partner in this project. The frame was adapted and every components were checked for the ex vivo validation tests. CT imaging was taken in Lodi at Università degli studi di Milano, Facoltà di Medicina Veterinaria, with CT scanner and MRI imaging was taken in La Cittadina, Cremona Results System validation was approved by the ex vivo trial. The frame system doesn’t compromise the imaging acquisition in MRI and CT systems. Every system components are functional to their aims. Discussion The Frame system is adapted to the sheep head. It is composed by elements able to lock the head during the imaging acquisition. Frame system is characterized by a support base helpings the animals to keep the head straight forward during imaging time, under general anesthesia. The design of these device support the airways anatomy, avoiding damaging or obstruction of airflows during anesthesia period. The role of elements like mouth bar and ovine head pins is to lock the head in a stable position during imaging acquisition; fixing is guaranteed by V shape head pins, that are arranged against the zygomatic arches. Lateral compression forces to the cranium, and the V shape pins avoid the vertical shifting of the head and any kind of rotations. (fig. 1

  13. Radiation protection

    International Nuclear Information System (INIS)

    Koelzer, W.

    1975-01-01

    Physical and radiological terms, quantities, and units. Basic principles of radiation protection (ICRP, IAEA, EURATOM, FRG). Biological effects of ionizing radiation. Objectives of practical radiation protection. (HP) [de

  14. An afterloading brachytherapy device utilizing thermoplastic material

    International Nuclear Information System (INIS)

    Kim, T.H.; Gerbi, J.B.; Deibel, F.C.; Khan, F.M.; Priest, J.R.

    1989-01-01

    An afterloading brachytherapy device for treatment of residual cancer in an enucleated orbit with two cesium-137 sources was designed using a thermoplastic material, Aquaplast. The device consists of a face-mask support held in place with elastic bands around the head and an acrylic afterloading applicator. The device is very easy to make, holds the sources firmly in place, allows full mobility of the patient, and gives excellent dose distribution to the target area. It was easily tolerated by a 7-year-old child during the 50 h of treatment. (author). 3 refs.; 4 figs

  15. Use your head

    DEFF Research Database (Denmark)

    Hansen, Thomas Riisgaard; Eriksson, Eva; Lykke-Olesen, Andreas

    2006-01-01

    In this paper we present how face tracking can be implemented on mobile devices. Our main contribution is to present how face tracking on mobile systems can be used as a multi-dimensional input technique and to demonstrate how this can be used in different mobile applications. We present at set...

  16. Safety in Cryogenics – Safety device sizing

    CERN Multimedia

    CERN. Geneva

    2016-01-01

    The calculation is separated in three operations: o The estimation of the loads arriving on the component to protect, o The calculation of the mass flow to evacuate, o And the sizing of the safety device.

  17. Damping device

    International Nuclear Information System (INIS)

    Banks, E.L. Jr.; Dowell, T.P.

    1976-01-01

    The description is given of a damper which includes a pair of telescopic components interconnected by relative linear movement one in relation to the other, by a screw and ball nut device, with a braking surface on one of the components, a brake engaging the braking surface, an inertia mass entrained by the other components, non-deformable and distinct brake actuating gear, independently mobile in relation to the other braking system and fixed and controlled by the inertia mass, positively to engage the braking surface. This damper is for retaining the parts of a nuclear power station so that can withstand earthquakes [fr

  18. Thermonuclear device

    International Nuclear Information System (INIS)

    Inoue, Toyokazu; Murata, Toru.

    1983-01-01

    Purpose: To shield superconducting coils for use in the generation of magnetic field against neutron irradiation thereby preventing tritium contamination. Constitution: The thermonuclear device comprises, in its inside, a vacuum container for containing plasmas, superconducting coils disposed to the outside of the vacuum container and neutron absorbers disposed between the super-conducting coils and the vacuum container. since neutrons issued from the plasma are absorbed by neutron absorbers and not irradiated to the superconducting coils, generation of tritium due to the reaction between 3 He in the liquid helium as the coolants for the super-conducting coils and the neutrons is prevented. (Aizawa, K.)

  19. Strainer device

    International Nuclear Information System (INIS)

    Mokuya, Kenji.

    1975-01-01

    Object: To provide a strainer device, which is adapted to facilitate flushing and is particularly suited for installation in the cooling system of a liquid metal cooled fast breeding reactor. Structure: A casing accommodating a strainer and a blind plate for the selection of a flow path is provided at a suitable portion of the duct line. The blind plate is adapted to be rotated by an opening and closing means consisting of a rod. bellows, shaft and so forth. At the time of flushing, the duct line is sealed by the blind plate. (Nakamura, S.)

  20. Representation of heading direction in far and near head space

    NARCIS (Netherlands)

    Poljac, E.; Berg, A.V. van den

    2003-01-01

    Manipulation of objects around the head requires an accurate and stable internal representation of their locations in space, also during movements such as that of the eye or head. For far space, the representation of visual stimuli for goal-directed arm movements relies on retinal updating, if eye